Sample records for targeted indoor residual

  1. Targeting indoor residual spraying for malaria using epidemiological data: a case study of the Zambia experience.

    PubMed

    Pinchoff, Jessie; Larsen, David A; Renn, Silvia; Pollard, Derek; Fornadel, Christen; Maire, Mark; Sikaala, Chadwick; Sinyangwe, Chomba; Winters, Benjamin; Bridges, Daniel J; Winters, Anna M

    2016-01-06

    In Zambia and other sub-Saharan African countries affected by ongoing malaria transmission, indoor residual spraying (IRS) for malaria prevention has typically been implemented over large areas, e.g., district-wide, and targeted to peri-urban areas. However, there is a recent shift in some countries, including Zambia, towards the adoption of a more strategic and targeted IRS approach, in coordination with increased emphasis on universal coverage of long-lasting insecticidal nets (LLINs) and effective insecticide resistance management. A true targeted approach would deliver IRS to sub-district areas identified as high-risk, with the goal of maximizing the prevention of malaria cases and deaths. Together with the Government of the Republic of Zambia, a new methodology was developed applying geographic information systems and satellite imagery to support a targeted IRS campaign during the 2014 spray season using health management information system data. This case study focuses on the developed methodology while also highlighting the significant research gaps which must be filled to guide countries on the most effective strategy for IRS targeting in the context of universal LLIN coverage and evolving insecticide resistance.

  2. Reported community-level indoor residual spray coverage from two-stage cluster surveys in sub-Saharan Africa.

    PubMed

    Larsen, David A; Borrill, Lauren; Patel, Ryan; Fregosi, Lauren

    2017-06-13

    Malaria is an important cause of morbidity and mortality in malaria-endemic areas. Indoor residual spray is an effective intervention to control malaria, but high community-level coverage is needed to maximize its impact. Using thirty-four two-stage cluster surveys (e.g., demographic and health surveys) and lot quality assurance sampling, indoor residual spray was estimated at the community level (i.e. enumeration-area) across sub-Saharan Africa since 2010. For communities receiving indoor residual spray a logistic regression predicted whether community-level coverage exceeded 50% or not. Household-level coverage was equitable both in terms of wealth and urban/rural, with poorer and rural houses more likely to be sprayed than richer and urban houses. Coverage of indoor residual spray at the community level is poor across the continent, with 54% of communities receiving the intervention not reaching 50% coverage. Having >50% coverage at the community-level was not associated with increasing the number of houses sprayed in the country. Implementation and monitoring of indoor residual coverage at small geographical scales need to improve greatly to receive maximum benefit of the intervention.

  3. Comparing water, bovine milk, and indoor residual spraying as possible sources of DDT and pyrethroid residues in breast milk.

    PubMed

    Sereda, Barbara; Bouwman, Henk; Kylin, Henrik

    2009-01-01

    The presence of pollutants in human breast milk is of major concern, especially in malaria control areas where 1,1,1-trichloro-2,2-bis(4-chlorophenyl) ethane (DDT) is currently used as indoor residual spray (IRS). The levels of DDT and pyrethroids (PYR) were determined in breast milk, bovine milk, and drinking water from northern KwaZulu-Natal, South Africa. Both reference and exposed mothers used the same market food, but the DDT levels in the exposed mothers (mean SigmaDDT 10 microg/g milk fat [mf]) were much higher than for the reference mothers (mean SigmaDDT 1.3 microg/g milk fat). This difference in residue levels indicates uptake from IRS-applied DDT, most likely via air and skin contact, and excludes food as the main source of pollutants. DDT levels in bovine milk (mean SigmaDDT 0.15 microg/g mf) from the exposed area were less than levels in breast milk from the reference area, and lower than the 20 microg/L maximum residue limit (MRL) set by the Food and Agriculture Organization (FAO). Mean SigmaDDT in water was 0.0065 microg/L, much lower then the WHO limit of the sum of all metabolites in drinking water of 1 microg/L, and therefore highly unlikely to have contributed to any extent toward levels in breast milk. Permethrin in breast milk (mean 1.1-1.6 microg/g milk fat) was probably derived from home garden and indoor use, while the other PYR (cypermethrin and cyfluthrin) at lower concentrations were probably derived from food and agricultural exposure. It is postulated that a better understanding of the indoor dynamics of DDT and other insecticides, through a concept of Total Homestead Environment Approach (THEA), is crucial for investigating options of reducing human exposure and uptake under malaria control conditions.

  4. DDT-based indoor residual spraying suboptimal for visceral leishmaniasis elimination in India.

    PubMed

    Coleman, Michael; Foster, Geraldine M; Deb, Rinki; Pratap Singh, Rudra; Ismail, Hanafy M; Shivam, Pushkar; Ghosh, Ayan Kumar; Dunkley, Sophie; Kumar, Vijay; Coleman, Marlize; Hemingway, Janet; Paine, Mark J I; Das, Pradeep

    2015-07-14

    Indoor residual spraying (IRS) is used to control visceral leishmaniasis (VL) in India, but it is poorly quality assured. Quality assurance was performed in eight VL endemic districts in Bihar State, India, in 2014. Residual dichlorodiphenyltrichloroethane (DDT) was sampled from walls using Bostik tape discs, and DDT concentrations [grams of active ingredient per square meter (g ai/m(2))] were determined using HPLC. Pre-IRS surveys were performed in three districts, and post-IRS surveys were performed in eight districts. A 20% threshold above and below the target spray of 1.0 g ai/m(2) was defined as "in range." The entomological assessments were made in four districts in IRS and non-IRS villages. Vector densities were measured: pre-IRS and 1 and 3 mo post-IRS. Insecticide susceptibility to 4% DDT and 0.05% deltamethrin WHO-impregnated papers was determined with wild-caught sand flies. The majority (329 of 360, 91.3%) of pre-IRS samples had residual DDT concentrations of <0.1 g ai/m(2). The mean residual concentration of DDT post-IRS was 0.37 g ai/m(2); 84.9% of walls were undersprayed, 7.4% were sprayed in range, and 7.6% were oversprayed. The abundance of sand flies in IRS and non-IRS villages was significantly different at 1 mo post-IRS only. Sand flies were highly resistant to DDT but susceptible to deltamethrin. The Stockholm Convention, ratified by India in 2006, calls for the complete phasing out of DDT as soon as practical, with limited use in the interim where no viable IRS alternatives exist. Given the poor quality of the DDT-based IRS, ready availability of pyrethroids, and susceptibility profile of Indian sand flies, the continued use of DDT in this IRS program is questionable.

  5. DDT-based indoor residual spraying suboptimal for visceral leishmaniasis elimination in India

    PubMed Central

    Coleman, Michael; Foster, Geraldine M.; Deb, Rinki; Pratap Singh, Rudra; Ismail, Hanafy M.; Shivam, Pushkar; Ghosh, Ayan Kumar; Dunkley, Sophie; Kumar, Vijay; Coleman, Marlize; Hemingway, Janet; Paine, Mark J. I.; Das, Pradeep

    2015-01-01

    Indoor residual spraying (IRS) is used to control visceral leishmaniasis (VL) in India, but it is poorly quality assured. Quality assurance was performed in eight VL endemic districts in Bihar State, India, in 2014. Residual dichlorodiphenyltrichloroethane (DDT) was sampled from walls using Bostik tape discs, and DDT concentrations [grams of active ingredient per square meter (g ai/m2)] were determined using HPLC. Pre-IRS surveys were performed in three districts, and post-IRS surveys were performed in eight districts. A 20% threshold above and below the target spray of 1.0 g ai/m2 was defined as “in range.” The entomological assessments were made in four districts in IRS and non-IRS villages. Vector densities were measured: pre-IRS and 1 and 3 mo post-IRS. Insecticide susceptibility to 4% DDT and 0.05% deltamethrin WHO-impregnated papers was determined with wild-caught sand flies. The majority (329 of 360, 91.3%) of pre-IRS samples had residual DDT concentrations of <0.1 g ai/m2. The mean residual concentration of DDT post-IRS was 0.37 g ai/m2; 84.9% of walls were undersprayed, 7.4% were sprayed in range, and 7.6% were oversprayed. The abundance of sand flies in IRS and non-IRS villages was significantly different at 1 mo post-IRS only. Sand flies were highly resistant to DDT but susceptible to deltamethrin. The Stockholm Convention, ratified by India in 2006, calls for the complete phasing out of DDT as soon as practical, with limited use in the interim where no viable IRS alternatives exist. Given the poor quality of the DDT-based IRS, ready availability of pyrethroids, and susceptibility profile of Indian sand flies, the continued use of DDT in this IRS program is questionable. PMID:26124110

  6. Indoor detection of passive targets recast as an inverse scattering problem

    NASA Astrophysics Data System (ADS)

    Gottardi, G.; Moriyama, T.

    2017-10-01

    The wireless local area networks represent an alternative to custom sensors and dedicated surveillance systems for target indoor detection. The availability of the channel state information has opened the exploitation of the spatial and frequency diversity given by the orthogonal frequency division multiplexing. Such a fine-grained information can be used to solve the detection problem as an inverse scattering problem. The goal of the detection is to reconstruct the properties of the investigation domain, namely to estimate if the domain is empty or occupied by targets, starting from the measurement of the electromagnetic perturbation of the wireless channel. An innovative inversion strategy exploiting both the frequency and the spatial diversity of the channel state information is proposed. The target-dependent features are identified combining the Kruskal-Wallis test and the principal component analysis. The experimental validation points out the detection performance of the proposed method when applied to an existing wireless link of a WiFi architecture deployed in a real indoor scenario. False detection rates lower than 2 [%] have been obtained.

  7. Alternative treatments for indoor residual spraying for malaria control in a village with pyrethroid- and DDT-resistant vectors in the Gambia.

    PubMed

    Tangena, Julie-Anne A; Adiamoh, Majidah; D'Alessandro, Umberto; Jarju, Lamin; Jawara, Musa; Jeffries, David; Malik, Naiela; Nwakanma, Davis; Kaur, Harparkash; Takken, Willem; Lindsay, Steve W; Pinder, Margaret

    2013-01-01

    Malaria vector control is threatened by resistance to pyrethroids, the only class of insecticides used for treating bed nets. The second major vector control method is indoor residual spraying with pyrethroids or the organochloride DDT. However, resistance to pyrethroids frequently confers resistance to DDT. Therefore, alternative insecticides are urgently needed. Insecticide resistance and the efficacy of indoor residual spraying with different insecticides was determined in a Gambian village. Resistance of local vectors to pyrethroids and DDT was high (31% and 46% mortality, respectively) while resistance to bendiocarb and pirimiphos methyl was low (88% and 100% mortality, respectively). The vectors were predominantly Anopheles gambiae s.s. with 94% of them having the putative resistant genotype kdr 1014F. Four groups of eight residential compounds were each sprayed with either (1) bendiocarb, a carbamate, (2) DDT, an organochlorine, (3) microencapsulated pirimiphos methyl, an organophosphate, or (4) left unsprayed. All insecticides tested showed high residual activity up to five months after application. Mosquito house entry, estimated by light traps, was similar in all houses with metal roofs, but was significantly less in IRS houses with thatched roofs (p=0.02). Residents participating in focus group discussions indicated that IRS was considered a necessary nuisance and also may decrease the use of long-lasting insecticidal nets. Bendiocarb and microencapsulated pirimiphos methyl are viable alternatives for indoor residual spraying where resistance to pyrethroids and DDT is high and may assist in the management of pyrethroid resistance.

  8. 21 CFR 500.86 - Marker residue and target tissue.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Marker residue and target tissue. 500.86 Section...-Producing Animals § 500.86 Marker residue and target tissue. (a) For each edible tissue, the sponsor shall...) From these data, FDA will select a target tissue and a marker residue and designate the concentration...

  9. 21 CFR 500.86 - Marker residue and target tissue.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Marker residue and target tissue. 500.86 Section...-Producing Animals § 500.86 Marker residue and target tissue. (a) For each edible tissue, the sponsor shall...) From these data, FDA will select a target tissue and a marker residue and designate the concentration...

  10. A Behavioral Intervention to Reduce Child Exposure to Indoor Air Pollution: Identifying Possible Target Behaviors

    ERIC Educational Resources Information Center

    Barnes, Brendon R.; Mathee, Angela; Shafritz, Lonna B.; Krieger, Laurie; Zimicki, Susan

    2004-01-01

    Indoor air pollution has been causally linked to acute lower respiratory infections in children younger than 5. The aim of this study was to identify target behaviors for a behavioral intervention to reduce child exposure to indoor air pollution by attempting to answer two research questions: Which behaviors are protective of child respiratory…

  11. Alternative Treatments for Indoor Residual Spraying for Malaria Control in a Village with Pyrethroid- and DDT-Resistant Vectors in The Gambia

    PubMed Central

    Tangena, Julie-Anne A.; Adiamoh, Majidah; D’Alessandro, Umberto; Jarju, Lamin; Jawara, Musa; Jeffries, David; Malik, Naiela; Nwakanma, Davis; Kaur, Harparkash; Takken, Willem; Lindsay, Steve W.; Pinder, Margaret

    2013-01-01

    Background Malaria vector control is threatened by resistance to pyrethroids, the only class of insecticides used for treating bed nets. The second major vector control method is indoor residual spraying with pyrethroids or the organochloride DDT. However, resistance to pyrethroids frequently confers resistance to DDT. Therefore, alternative insecticides are urgently needed. Methodology/Principal Findings Insecticide resistance and the efficacy of indoor residual spraying with different insecticides was determined in a Gambian village. Resistance of local vectors to pyrethroids and DDT was high (31% and 46% mortality, respectively) while resistance to bendiocarb and pirimiphos methyl was low (88% and 100% mortality, respectively). The vectors were predominantly Anopheles gambiae s.s. with 94% of them having the putative resistant genotype kdr 1014F. Four groups of eight residential compounds were each sprayed with either (1) bendiocarb, a carbamate, (2) DDT, an organochlorine, (3) microencapsulated pirimiphos methyl, an organophosphate, or (4) left unsprayed. All insecticides tested showed high residual activity up to five months after application. Mosquito house entry, estimated by light traps, was similar in all houses with metal roofs, but was significantly less in IRS houses with thatched roofs (p=0.02). Residents participating in focus group discussions indicated that IRS was considered a necessary nuisance and also may decrease the use of long-lasting insecticidal nets. Conclusion/Significance Bendiocarb and microencapsulated pirimiphos methyl are viable alternatives for indoor residual spraying where resistance to pyrethroids and DDT is high and may assist in the management of pyrethroid resistance. PMID:24058551

  12. Pest Prevalence and Evaluation of Community-Wide Integrated Pest Management for Reducing Cockroach Infestations and Indoor Insecticide Residues.

    PubMed

    Zha, Chen; Wang, Changlu; Buckley, Brian; Yang, Ill; Wang, Desen; Eiden, Amanda L; Cooper, Richard

    2018-04-02

    Pest infestations in residential buildings are common, but community-wide pest survey data are lacking. Frequent insecticide applications for controlling indoor pests leave insecticide residues and pose potential health risks to residents. In this study, a community-wide pest survey was carried out in a housing complex consisting of 258 units in 40 buildings in New Brunswick, New Jersey. It was immediately followed by implementation of an integrated pest management (IPM) program in all the cockroach-infested apartments and two bed bug apartments with the goal of eliminating pest infestations, reducing pyrethroid residues, and increasing resident satisfaction with pest control services. The IPM-treated apartments were revisited and treated biweekly or monthly for 7 mo. Initial inspection found the top three pests and their infestation rates to be as follows: German cockroaches (Blattella germanica L. [Blattodea: Blattellidae]), 28%; rodents, 11%; and bed bugs (Cimex lectularius L. [Hemiptera: Cimicidae]), 8%. Floor wipe samples were collected in the kitchens and bedrooms of 20 apartments for pyrethroid residue analysis before the IPM implementation; 17 of the 20 apartments were resampled again at 7 mo. The IPM program reduced cockroach counts per apartment by 88% at 7 wk after initial treatment. At 7 mo, 85% of the cockroach infestations found in the initial survey were eliminated. The average number of pyrethroids detected decreased significantly from 6 ± 1 (mean ± SEM) and 5 ± 1 to 2 ± 1 and 3 ± 1 in the kitchens and bedrooms, respectively. The average concentrations of targeted pyrethroids residue also decreased significantly in the kitchens and bedrooms.

  13. Effectiveness of a long-lasting piperonyl butoxide-treated insecticidal net and indoor residual spray interventions, separately and together, against malaria transmitted by pyrethroid-resistant mosquitoes: a cluster, randomised controlled, two-by-two factorial design trial.

    PubMed

    Protopopoff, Natacha; Mosha, Jacklin F; Lukole, Eliud; Charlwood, Jacques D; Wright, Alexandra; Mwalimu, Charles D; Manjurano, Alphaxard; Mosha, Franklin W; Kisinza, William; Kleinschmidt, Immo; Rowland, Mark

    2018-04-21

    Progress in malaria control is under threat by wide-scale insecticide resistance in malaria vectors. Two recent vector control products have been developed: a long-lasting insecticidal net that incorporates a synergist piperonyl butoxide (PBO) and a long-lasting indoor residual spraying formulation of the insecticide pirimiphos-methyl. We evaluated the effectiveness of PBO long-lasting insecticidal nets versus standard long-lasting insecticidal nets as single interventions and in combination with the indoor residual spraying of pirimiphos-methyl. We did a four-group cluster randomised controlled trial using a two-by-two factorial design of 48 clusters derived from 40 villages in Muleba (Kagera, Tanzania). We randomly assigned these clusters using restricted randomisation to four groups: standard long-lasting insecticidal nets, PBO long-lasting insecticidal nets, standard long-lasting insecticidal nets plus indoor residual spraying, or PBO long-lasting insecticidal nets plus indoor residual spraying. Both standard and PBO nets were distributed in 2015. Indoor residual spraying was applied only once in 2015. We masked the inhabitants of each cluster to the type of nets received, as well as field staff who took blood samples. Neither the investigators nor the participants were masked to indoor residual spraying. The primary outcome was the prevalence of malaria infection in children aged 6 months to 14 years assessed by cross-sectional surveys at 4, 9, 16, and 21 months after intervention. The endpoint for assessment of indoor residual spraying was 9 months and PBO long-lasting insecticidal nets was 21 months. This trial is registered with ClinicalTrials.gov, number NCT02288637. 7184 (68·0%) of 10 560 households were selected for post-intervention survey, and 15 469 (89·0%) of 17 377 eligible children from the four surveys were included in the intention-to-treat analysis. Of the 878 households visited in the two indoor residual spraying groups, 827 (94%) had

  14. 21 CFR 500.86 - Marker residue and target tissue.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS GENERAL Regulation of Carcinogenic Compounds Used in Food-Producing Animals § 500.86 Marker residue and target tissue. (a) For each edible tissue, the sponsor shall... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Marker residue and target tissue. 500.86 Section...

  15. 21 CFR 500.86 - Marker residue and target tissue.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS GENERAL Regulation of Carcinogenic Compounds Used in Food-Producing Animals § 500.86 Marker residue and target tissue. (a) For each edible tissue, the sponsor shall... 21 Food and Drugs 6 2014-04-01 2014-04-01 false Marker residue and target tissue. 500.86 Section...

  16. 21 CFR 500.86 - Marker residue and target tissue.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS GENERAL Regulation of Carcinogenic Compounds Used in Food-Producing Animals § 500.86 Marker residue and target tissue. (a) For each edible tissue, the sponsor shall... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Marker residue and target tissue. 500.86 Section...

  17. RESIDENTIAL INDOOR EXPOSURES OF CHILDREN TO PESTICIDES FOLLOWING LAWN APPLICATIONS

    EPA Science Inventory

    Methods have been developed to estimate children's residential exposures to pesticide residues and applied in a small field study of indoor exposures resulting from the intrusion of lawn-applied herbicide into the home. Sampling methods included size-selective indoor air sampli...

  18. Laboratory Evaluation of Residual Efficacy of Actellic 300 CS (Pirimiphos-Methyl) and K-Othrine WG 250 (Deltamethrin) on Different Indoor Surfaces.

    PubMed

    Ibrahim, Kolade T; Popoola, Kehinde O; Akure, Kenneth O

    2017-01-01

    The nature and type of local indoor resting wall surfaces to certain level influences the residual bio-efficacy of insecticides used in indoor residual spraying programs. Knockdown and mortality effects of an organophosphate Actellic 300 CS and pyrethroid K-Othrine WG 250 insecticides on the field-collected Culex quinquefasciatus were assessed bimonthly from July to November 2014, using World Health Organization (WHO) cones bioassay test. Knockdown and mortality rates were subjected to statistical analysis using χ 2 and Student t tests. Result of the bioassay test on C quinquefasciatus showed that plywood surfaces had the best residual knockdown activity of Actellic 300 CS with knockdown rate above the WHO-recommended threshold limit of ≥95% for 30 days after treatment. This was followed by mud surface with knockdown rates ≥95% threshold limit 15 days (97%) after treatment. The lowest knockdown rates of less than 95% were observed on cement surface throughout the assessment period. However, the knockdown rates of mosquitoes on deltamethrin WG 250-treated cement and plywood surfaces were 100% and ≥95%, respectively, at 30 days after treatment. But the knockdown activity was below the recommended threshold limit on mud surface during the 17 weeks trial. Knockdown activities varied significantly ( p  < .05), and it is a function of exposure periods, different surfaces, and insecticide formulations. The 24-hour mortality rates of Actellic 300 CS and K-Othrine WG 250 at 120 days after treatment were 83.6% and 86.7%, and 80% and 83.3%, on plywood and cement surfaces, respectively. A maximum residual period of 75 and 45 days were recorded for Actellic 300 CS and K-Othrine WG 250, respectively, on mud surface. Both Actellic 300 CS and K-Othrine 250 WG were highly effective against Culex mosquito. The extended residual activity of p -methyl CS compared with deltamethrin WG 250 makes it a suitable alternative insecticide against pyrethroid

  19. Line Segmentation of 2d Laser Scanner Point Clouds for Indoor Slam Based on a Range of Residuals

    NASA Astrophysics Data System (ADS)

    Peter, M.; Jafri, S. R. U. N.; Vosselman, G.

    2017-09-01

    Indoor mobile laser scanning (IMLS) based on the Simultaneous Localization and Mapping (SLAM) principle proves to be the preferred method to acquire data of indoor environments at a large scale. In previous work, we proposed a backpack IMLS system containing three 2D laser scanners and an according SLAM approach. The feature-based SLAM approach solves all six degrees of freedom simultaneously and builds on the association of lines to planes. Because of the iterative character of the SLAM process, the quality and reliability of the segmentation of linear segments in the scanlines plays a crucial role in the quality of the derived poses and consequently the point clouds. The orientations of the lines resulting from the segmentation can be influenced negatively by narrow objects which are nearly coplanar with walls (like e.g. doors) which will cause the line to be tilted if those objects are not detected as separate segments. State-of-the-art methods from the robotics domain like Iterative End Point Fit and Line Tracking were found to not handle such situations well. Thus, we describe a novel segmentation method based on the comparison of a range of residuals to a range of thresholds. For the definition of the thresholds we employ the fact that the expected value for the average of residuals of n points with respect to the line is σ / √n. Our method, as shown by the experiments and the comparison to other methods, is able to deliver more accurate results than the two approaches it was tested against.

  20. Indoor residual spraying with micro-encapsulated pirimiphos-methyl (Actellic® 300CS) against malaria vectors in the Lake Victoria basin, Tanzania

    PubMed Central

    Manjurano, Alphaxard; Kinung’hi, Safari; Martine, Jackline; Lyimo, Eric; Kishamawe, Coleman; Ndege, Chacha; Ramsan, Mahdi M.; Chan, Adeline; Mwalimu, Charles D.; Changalucha, John; Magesa, Stephen

    2017-01-01

    Background The indoor residual spraying programme for malaria vectors control was implemented in four districts of the Lake Victoria basin of Tanzania namely Ukerewe, Sengerema, Rorya andSerengeti. Entomological monitoring activities were implemented in one sentinel village in each district to evaluate the efficacy of pirimiphos-methyl 300 CS sprayed on different wall surfaces and its impact against malaria vectors post-IRS intervention. Methods The residual decay rate of p-methyl 300 CS applied at a target dosage of 1g a.i./m2 on thesprayed wall surfaces was monitored for a period of 43 weeks post-IRSusing the WHO cone wall bioassay method. The bioassays were performed by exposing 2–5 days old unfed susceptible female Anopheles gambiae s.s. (Kisumu strain) to sprayed wall surfaces for a period of 30 minutes. In each sentinel village, mosquito collection was carried out by trained community mosquito collectors. Monthly mosquito collections were carried out from 6.00pm to 6.00am using CDC light traps and clay pot methods for indoors host seekingand outdoors resting mosquitoes respectively. Six traps (2 CDC light traps and 4 clay pots) were set per sentinel village per night for28 consecutive days in a moon. PCR and ELISA were used for mosquito species identification and sporozoite detection, respectively. Results Based on the WHOPES recommendation, insecticides should have a minimum efficacy of ≥ 80% mosquito mortality at 24 hours post exposure on the sprayed wall surfaces to be considered effective. In this study, p-methyl 300 CS was demonstrated to have a long residual efficacy of 21–43 weeks post-IRS on mud, cement, painted and wood wall surfaces. Numberof anopheline mosquitoes decreased post-IRS interventions in all sentinel villages. The highest numbers ofanopheline mosquitoes were collected in November-December, 38–43 weeks post-IRS. A total of 270 female anopheline mosquitoes were analyzed by PCR; out of which 236 (87.4%) were An. gambiae s.l. and 34

  1. PESTICIDE RESIDUE RECOVERIES FROM SURFACE WIPES

    EPA Science Inventory

    Human exposure is a consequence of pesticide use indoors with a primary source resulting from residue deposition on household surfaces. Accurate measurements of surface residues is essential for estimating exposure from different routes. Various procedures have been developed ...

  2. Estimation of human body concentrations of DDT from indoor residual spraying for malaria control.

    PubMed

    Gyalpo, Tenzing; Fritsche, Lukas; Bouwman, Henk; Bornman, Riana; Scheringer, Martin; Hungerbühler, Konrad

    2012-10-01

    Inhabitants of dwellings treated with DDT for indoor residual spraying show high DDT levels in blood and breast milk. This is of concern since mothers transfer lipid-soluble contaminants such as DDT via breastfeeding to their children. Focusing on DDT use in South Africa, we employ a pharmacokinetic model to estimate DDT levels in human lipid tissue over the lifetime of an individual to determine the amount of DDT transferred to children during breastfeeding, and to identify the dominant DDT uptake routes. In particular, the effects of breastfeeding duration, parity, and mother's age on DDT concentrations of mother and infant are investigated. Model results show that primiparous mothers have greater DDT concentrations than multiparous mothers, which causes higher DDT exposure of first-born children. DDT in the body mainly originates from diet. Generally, our modeled DDT levels reproduce levels found in South African biomonitoring data within a factor of 3. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. Village-scale (Phase III) evaluation of the efficacy and residual activity of SumiShield® 50 WG (Clothianidin 50%, w/w) for indoor spraying for the control of pyrethroid-resistant Anopheles culicifacies Giles in Karnataka state, India.

    PubMed

    Uragayala, S; Kamaraju, R; Tiwari, S N; Sreedharan, S; Ghosh, S K; Valecha, N

    2018-06-01

    There is an urgent need to test and incorporate new molecules with promising efficacy and novel mode of action to control insecticide-resistant mosquito vectors for disease control. We tested a new compound, clothianidin (SumiShield 50 WG), for its efficacy as an indoor residual spray (IRS) for the control of pyrethroid-resistant Anopheles culicifacies (Diptera: Culicidae) in comparison with pirimiphos methyl (Actellic CS) as a positive control. Ten villages were selected, five each for IRS with clothianidin (300 mg AI/m 2 ) and pirimiphos methyl (1000 mg AI/m 2 ) in Almatti Dam catchment area in Karnataka state, India. Entomological parameters were monitored in these sprayed villages using standard methods. Assessment of quality of spray was performed by analysing the insecticide content in the filter paper samples collected from sprayed houses. Perceptions of spray men and inhabitants were recorded post-spray on safety of these molecules. The mean applied to target ratio of content was 1.7 (n = 29) for clothianidin and 1.8 (n = 50) for pirimiphos methyl on filter paper samples analysed. Residual activity (≥80% mortality in exposed mosquitoes) after 24 h post-exposure of SumiShield WG was 5 months and increased to 6 months when the holding period was extended to 120 h and that of Actellic CS was 3 months at 24-h holding period and extended to 4 months at 120-h extended holding period. The mean densities of An. culicifacies in both arms fell drastically post-spray. In light trap collections, density of mosquitoes collected indoors was lower than outdoors in both arms indicating effectiveness of IRS. SumiShield WG was more efficacious in reducing the per-structure density than Actellic CS. The proportion of nulliparous mosquitoes was higher than that of parous mosquitoes during post-spray collections in both arms. The majority of adverse events reported were transitory and subsided without medication. Indoor residual spraying with SumiShield WG was found effective

  4. Vitamin D analogues to target residual proteinuria: potential impact on cardiorenal outcomes

    PubMed Central

    Humalda, Jelmer K.; Goldsmith, David J. A.; Thadhani, Ravi; de Borst, Martin H.

    2015-01-01

    Residual proteinuria, the amount of proteinuria that remains during optimally dosed renin-angiotensin-aldosterone system (RAAS) blockade, is an independent risk factor for progressive renal function loss and cardiovascular complications in chronic kidney disease (CKD) patients. Dual RAAS blockade may reduce residual proteinuria but without translating into improved cardiorenal outcomes at least in diabetic nephropathy; rather, dual RAAS blockade may increase the risk of adverse events. These findings have challenged the concept of residual proteinuria as an absolute treatment target. Therefore, new strategies must be explored to address whether by further reduction of residual proteinuria using interventions not primarily targeting the RAAS benefit in terms of cardiorenal risk reduction would accrue. Both clinical and experimental intervention studies have demonstrated that vitamin D can reduce residual proteinuria through both RAAS-dependent and RAAS-independent pathways. Future research should prospectively explore vitamin D treatment as an adjunct to RAAS blockade in an interventional trial exploring clinically relevant cardiorenal end points. PMID:25609737

  5. The Isprs Benchmark on Indoor Modelling

    NASA Astrophysics Data System (ADS)

    Khoshelham, K.; Díaz Vilariño, L.; Peter, M.; Kang, Z.; Acharya, D.

    2017-09-01

    Automated generation of 3D indoor models from point cloud data has been a topic of intensive research in recent years. While results on various datasets have been reported in literature, a comparison of the performance of different methods has not been possible due to the lack of benchmark datasets and a common evaluation framework. The ISPRS benchmark on indoor modelling aims to address this issue by providing a public benchmark dataset and an evaluation framework for performance comparison of indoor modelling methods. In this paper, we present the benchmark dataset comprising several point clouds of indoor environments captured by different sensors. We also discuss the evaluation and comparison of indoor modelling methods based on manually created reference models and appropriate quality evaluation criteria. The benchmark dataset is available for download at: indoor-modelling.html"target="_blank">http://www2.isprs.org/commissions/comm4/wg5/benchmark-on-indoor-modelling.html.

  6. Feasibility and Effectiveness of mHealth for Mobilizing Households for Indoor Residual Spraying to Prevent Malaria: A Case Study in Mali

    PubMed Central

    Mangam, Keith; Fiekowsky, Elana; Bagayoko, Moussa; Norris, Laura; Belemvire, Allison; Longhany, Rebecca; Fornadel, Christen; George, Kristen

    2016-01-01

    ABSTRACT Components of mHealth are increasingly being added to development interventions worldwide. A particular case of interest is in Mali where the U.S. President’s Malaria Initiative (PMI) Africa Indoor Residual Spraying (AIRS) Project piloted a mobile mass-messaging service in Koulikoro District in August 2014 to determine whether voice and/or text messages received on cell phones could effectively replace door-to-door mobilization for an indoor residual spraying (IRS) campaign. To measure the pilot’s effectiveness, we evaluated structure preparedness (all household and food items removed) in 3 pilot intervention villages compared with 3 villages prepared for spray through door-to-door mobilization that was modified by incorporating town hall meetings and radio spots. Structure preparedness was significantly lower in households mobilized through the mobile-messaging approach compared with the door-to-door approach (49% vs. 75%, respectively; P = .03). Spray coverage of targeted households also was significantly lower among the mobile-messaging villages than the door-to-door mobilization villages (86% vs. 96%, respectively; P = .02). The mobile-messaging approach, at US$8.62 per structure prepared, was both more costly and less effective than the door-to-door approach at US$1.08 per structure prepared. While literacy and familiarity with technology were major obstacles, it also became clear that by removing the face-to-face interactions between mobilizers and household residents, individuals were not as trusting or understanding of the mobilization messages. These residents felt it was easier to ignore a text or voice message than to ignore a mobilizer who could provide reassurances and preparation support. In addition, men often received the mobile messages, as they typically owned the mobile phones, while women—who were more likely to be at home at the time of spray—usually interacted with the door-to-door mobilizers. Future attempts at using

  7. Feasibility and Effectiveness of mHealth for Mobilizing Households for Indoor Residual Spraying to Prevent Malaria: A Case Study in Mali.

    PubMed

    Mangam, Keith; Fiekowsky, Elana; Bagayoko, Moussa; Norris, Laura; Belemvire, Allison; Longhany, Rebecca; Fornadel, Christen; George, Kristen

    2016-06-20

    Components of mHealth are increasingly being added to development interventions worldwide. A particular case of interest is in Mali where the U.S. President's Malaria Initiative (PMI) Africa Indoor Residual Spraying (AIRS) Project piloted a mobile mass-messaging service in Koulikoro District in August 2014 to determine whether voice and/or text messages received on cell phones could effectively replace door-to-door mobilization for an indoor residual spraying (IRS) campaign. To measure the pilot's effectiveness, we evaluated structure preparedness (all household and food items removed) in 3 pilot intervention villages compared with 3 villages prepared for spray through door-to-door mobilization that was modified by incorporating town hall meetings and radio spots. Structure preparedness was significantly lower in households mobilized through the mobile-messaging approach compared with the door-to-door approach (49% vs. 75%, respectively; P = .03). Spray coverage of targeted households also was significantly lower among the mobile-messaging villages than the door-to-door mobilization villages (86% vs. 96%, respectively; P = .02). The mobile-messaging approach, at US$8.62 per structure prepared, was both more costly and less effective than the door-to-door approach at US$1.08 per structure prepared. While literacy and familiarity with technology were major obstacles, it also became clear that by removing the face-to-face interactions between mobilizers and household residents, individuals were not as trusting or understanding of the mobilization messages. These residents felt it was easier to ignore a text or voice message than to ignore a mobilizer who could provide reassurances and preparation support. In addition, men often received the mobile messages, as they typically owned the mobile phones, while women-who were more likely to be at home at the time of spray-usually interacted with the door-to-door mobilizers. Future attempts at using m

  8. Household perceptions and subjective valuations of indoor residual spraying programmes to control malaria in northern Uganda.

    PubMed

    Brown, Zachary S; Kramer, Randall A; Ocan, David; Oryema, Christine

    2016-10-06

    Insecticide-based tools remain critical for controlling vector-borne diseases in Uganda. Securing public support from targeted populations for such tools is an important component in sustaining their long-run effectiveness. Yet little quantitative evidence is available on the perceived benefits and costs of vector control programmes among targeted households. A survey was administered to a clustered random sample of 612 households in Gulu and Oyam districts of northern Uganda during a period of very high malaria transmission and following a pilot indoor residual spray (IRS) programme. A discrete choice experiment was conducted within the survey, in which respondents indicated their preferences for different IRS programmes relative to money compensation in a series of experimentally controlled, hypothetical choice sets. The data were analysed using conditional logit regression models to estimate respondents' willingness to accept (WTA) some amount of money compensation in lieu of foregone malaria risk reductions. Latent class models were used to analyse whether respondent characteristics predicted WTA. Average WTA is estimated at $8.94 annually for a 10 % reduction in malaria risk, and additional co-benefits of IRS were estimated to be worth on average $54-$56 (depending on insecticide type) per round of IRS. Significant heterogeneity is observed: Four in five household heads in northern Uganda have high valuations for IRS programmes, while the remaining 20 % experience costly side effects of IRS (valued at between $2 and $3 per round). Statistically significant predictors of belonging to the high-value group include respondent gender, mean age of household members, participation in previous IRS, basic knowledge of mosquito reproduction, and the number of mosquito nets owned. Proxies for household income and wealth are not found to be statistically significant predictors of WTA. This study suggests that the majority of people in areas of high malaria transmission

  9. Acceptability and perceived side effects of insecticide indoor residual spraying under different resistance management strategies.

    PubMed

    Rodríguez, Américo David; Penilla, Rosa Patricia; Rodríguez, Mario Henry; Hemingway, Janet; Trejo, Antonio; Hernández-Avila, Juan Eugenio

    2006-01-01

    To assess household acceptability and perceived side effects of residual indoor pyrethroid (PYR), carbamate and organophosphate insecticides sprayed by annual rotation (ROT), spatial mosaic (MOS), and a single insecticide (DDT or PYR) in communities of the coastal plain of Chiapas, Mexico. A questionnaire to assess the acceptability and perceived side effects of indoor insecticides was administered to one member of 30% of the families in eight villages of Chiapas. The association of different insecticide treatments with their responses was evaluated (Chi-square). The intensity of side effects indicated under different treatments was compared in an ordered logistic model, using a severity index as the response variable. Insecticide spraying as a probable cause of symptoms was identified by 2.1% of interviewees. A significantly high percentage of persons with blurred vision, dizziness, sneezing, coughing, numbness, watery eyes, and itching lived in villages under MOS and ROT and a high severity index was significantly associated with ROT treatment. Reduction of mosquito bites and cockroaches were the perceived main benefits, and most villagers that perceived no benefits lived in DDT treated villages. Most of the interviewees welcomed spraying (83.7%), but the smell and having to remove furniture from houses were the main arguments against it. Acceptability correlated with insecticide spray coverage, although the most frequent suggestion for improvement was to increase the understanding of the objectives of spraying in the communities. The frequency of side effects was low, but higher in localities where a combination of insecticides was applied. This is a limitation for the use of this type of resistance management strategy in public health.

  10. Efficacy, persistence and vector susceptibility to pirimiphos-methyl (Actellic 300CS) insecticide for indoor residual spraying in Zanzibar.

    PubMed

    Haji, Khamis A; Thawer, Narjis G; Khatib, Bakari O; Mcha, Juma H; Rashid, Abdallah; Ali, Abdullah S; Jones, Christopher; Bagi, Judit; Magesa, Stephen M; Ramsan, Mahdi M; Garimo, Issa; Greer, George; Reithinger, Richard; Ngondi, Jeremiah M

    2015-12-09

    Indoor residual spraying (IRS) of households with insecticide is a principal malaria vector control intervention in Zanzibar. In 2006, IRS using the pyrethroid lambda-cyhalothrine was introduced in Zanzibar. Following detection of pyrethroid resistance in 2010, an insecticide resistance management plan was proposed, and IRS using bendiocarb was started in 2011. In 2014, bendiocarb was replaced by pirimiphos methyl. This study investigated the residual efficacy of pirimiphos methyl (Actellic 300CS) sprayed on common surfaces of human dwellings in Zanzibar. The residual activity of Actellic 300CS was determined over 9 months through bioassay tests that measured the mortality of female Anopheles mosquitoes, exposed to sprayed surfaces under a WHO cone. The wall surfaces included; mud wall, oil or water painted walls, lime washed wall, un-plastered cement block wall and stone blocks. Insecticide susceptibility testing was done to investigate the resistance status of local malaria vectors against Actellic 300CS using WHO protocols; Anopheline species were identified using PCR methods. Baseline tests conducted one-day post-IRS revealed 100% mortality on all sprayed surfaces. The residual efficacy of Actellic 300CS was maintained on all sprayed surfaces up to 8 months post-IRS. However, the bioassay test conducted 9 months post-IRS showed the 24 h mortality rate to be ≤80% for lime wash, mud wall, water paint and stone block surfaces. Only oil paint surface retained the recommended residual efficacy beyond 9 months post-IRS, with mortality maintained at ≥97 %. Results of susceptibility tests showed that malaria vectors in Zanzibar were fully (100%) susceptible to Actellic 300CS. The predominant mosquito vector species was An. arabiensis (76.0%) in Pemba and An. gambiae (83.5%) in Unguja. The microencapsulated formulation of pirimiphos methyl (Actellic 300CS) is a highly effective and appropriate insecticide for IRS use in Zanzibar as it showed a relatively prolonged

  11. Education versus regulation: The case for regulating the indoor tanning industry.

    PubMed

    Benet, Suzeanne; Kraft, Frederic

    2016-05-01

    We examine marketing strategies for indoor tanning services that often target young adult females. Evidence of the addictive nature of indoor tanning suggests that young adults may be vulnerable to the promotion of indoor tanning and as a result deserve greater protection from the marketing of these services. As public awareness of the rising numbers of skin cancers linked to indoor tanning grows, we believe that the public will support increased regulation of this industry.

  12. Undisturbed dust as a metric of long-term indoor insecticide exposure: Residential DDT contamination from indoor residual spraying and its association with serum levels in the VHEMBE cohort.

    PubMed

    Gaspar, Fraser W; Chevrier, Jonathan; Bornman, Riana; Crause, Madelein; Obida, Muvhulawa; Barr, Dana Boyd; Bradman, Asa; Bouwman, Henk; Eskenazi, Brenda

    2015-12-01

    Although approximately 123 million people may be exposed to high levels of insecticides through the use of indoor residual spraying (IRS) for malaria control, few studies exist on indoor insecticide contamination due to IRS and its relationship with human exposure. In the present study, we developed a sampling method to collect undisturbed dust from 50 homes in Limpopo, South Africa, a region where dichlorodiphenyltrichloroethane (DDT) has been used in IRS programs to prevent malaria for ~70years. We quantified DDT and its degradation products, dichlorodiphenyldichloroethylene (DDE), and dichlorodiphenyldichloroethane (DDD) in dust samples to determine dust loading levels and compared these levels to paired serum concentrations of p,p'-DDT and p,p'-DDE in women residents. p,p'-DDT and p,p'-DDE had the highest detection frequencies in both dust (58% and 34% detection, respectively) and serum samples (98% and 100% detection, respectively). Significantly higher detection frequencies for o,p'-DDT, p,p'-DDE, and p,p'-DDD were observed in dust samples collected in buildings that had been previously sprayed for malaria control. We also observed a significant, positive association between dust loading and serum concentrations of p,p'-DDT and p,p'-DDE (Spearman's rho=0.68 and 0.54, respectively). Despite the low detection frequency in dust, our results indicate that undisturbed dust may be a good metric to quantify long-term home exposure to DDT-related compounds and that contamination of the home environment may be an important determinant/source of DDT and DDE exposure. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Development and validation of a multi-residue method for the analysis of brominated and organophosphate flame retardants in indoor dust.

    PubMed

    He, Chang; Wang, Xianyu; Thai, Phong; Mueller, Jochen F; Gallen, Christie; Li, Yan; Baduel, Christine

    2017-03-01

    Flame retardants are associated to numerous adverse health effects, can accumulate in humans and have been used intensively worldwide. Recently, dust has been identified as a major human exposure route for flame retardants. The aim of this study was to develop a multi-residue method using a two-step SPE purification. It enabled us to effectively limit co-extracted matrix/interferets and therefore a simultaneous analysis of brominated and organophosphate flame retardants for indoor dust was achieved. The optimized method was validated according to standard protocol and achieved good accuracy and reproducibility (percent error ranged from -29% to 28%). Standard Reference Material (SRM) for dust was also analysed, and good agreement was found with reported brominated and organophosphate flame retardants (OPFRs) concentrations. The applicability of the validated method was demonstrated by the analysis of ten indoor dust samples from ten Australian homes. Overall 89% of the analytes were detected in these samples. The average concentrations of ∑OPFRs and ∑PBDEs in those samples were 41 and 3.6μg/g, respectively. Tris(2-butoxyethyl) phosphate and tris(2-chloroisopropyl) phosphate were the most abundant OPFRs, accounting for 57-92% ∑OPFRs, while decabromodiphenyl ether dominated the Polybrominated diphenyl ethers (PBDE) congeners contributing between 71-94% to the ∑PBDEs. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Indoor air pollution from unprocessed solid fuels in developing countries.

    PubMed

    Kaplan, Charlotte

    2010-01-01

    Approximately half of the world's population relies on biomass (primarily wood and agricultural residues) or coal fuels (collectively termed solid fuels) for heating, lighting, and cooking. The incomplete combustion of such materials releases byproducts with well-known adverse health effects, hence increasing the risk of many diseases and death. Among these conditions are acute respiratory infections, chronic obstructive pulmonary disease, heart disease, stroke, lung cancer, cataracts and blindness, tuberculosis, asthma, and adverse pregnancy outcomes. The International Agency for Research on Cancer has classified the indoor combustion of coal emissions as Group 1, a known carcinogen to humans. Indoor air pollution exposure is greatest in individuals who live in rural developing countries. Interventions have been limited and show only mixed results. To reduce the morbidity and mortality from indoor air pollution, countermeasures have to be developed that are practical, efficient, sustainable, and economical with involvement from the government, the commercial sector, and individuals. This review focuses on the contribution of solid fuels to indoor air pollution.

  15. Emerging developments in the standardized chemical characterization of indoor air quality.

    PubMed

    Nehr, Sascha; Hösen, Elisabeth; Tanabe, Shin-Ichi

    2017-01-01

    Despite the fact that the special characteristics of indoor air pollution make closed environments quite different from outdoor environments, the conceptual ideas for assessing air quality indoors and outdoors are similar. Therefore, the elaboration of International Standards for air quality characterization in view of controlling indoor air quality should resort to this common basis. In this short review we describe the possibilities of standardization of tools dedicated to indoor air quality characterization with a focus on the tools permitting to study the indoor air chemistry. The link between indoor exposure and health as well as the critical processes driving the indoor air quality are introduced. Available International Standards for the assessment of indoor air quality are depicted. The standards comprise requirements for the sampling on site, the analytical procedures, and the determination of material emissions. To date, these standardized procedures assure that indoor air, settled dust and material samples are analyzed in a comparable manner. However, existing International Standards exclusively specify conventional, event-driven target-screening using discontinuous measurement methods for long-lived pollutants. Therefore, this review draws a parallel between physico-chemical processes in indoor and outdoor environments. The achievements in atmospheric sciences also improve our understanding of indoor environments. The community of atmospheric scientists can be both ideal and supporter for researchers in the area of indoor air quality characterization. This short review concludes with propositions for future standardization activities for the chemical characterization of indoor air quality. Future standardization efforts should focus on: (i) the elaboration of standardized measurement methods and measurement strategies for online monitoring of long-lived and short-lived pollutants, (ii) the assessment of the potential and the limitations of non-target

  16. Occurrence of endocrine-disrupting chemicals in indoor dust

    PubMed Central

    Hwang, Hyun-Min; Park, Eun-Kee; Young, Thomas M.; Hammock, Bruce D.

    2010-01-01

    Human exposure to indoor dust enriched with endocrine-disrupting chemicals released from numerous indoor sources has been a focus of increasing concern. Longer residence times and elevated contaminant concentrations in the indoor environment may increase chances of exposure to these contaminants by 1000-fold compared to outdoor exposure. To investigate the occurrence of semi-volatile endocrine-disrupting chemicals, including PBDEs (polybrominated diphenyl ethers), PCBs (polychlorinated biphenyls), phthalates, pyrethroids, DDT (dichlorodiphenyltrichloroethane) and its metabolites, and chlordanes, indoor dust samples were collected from household vacuum cleaner bags provided by 10 apartments and 1 community hall in Davis, California, USA. Chemical analyses show that all indoor dust samples are highly contaminated by target analytes measured in the present study. Di-(2-ethylhexyl)phthalate was the most abundant (104–7630 μg/g) in all samples and higher than other target analytes by 2 to 6 orders of magnitude. PBDEs were also found at high concentrations (1780–25,200 ng/g). Although the use of PCBs has been banned or restricted for decades, some samples had PCBs at levels that are considered to be concerns for human health, indicating that the potential risk posed by PCBs still remains high in the indoor environment, probably due to a lack of dissipation processes and continuous release from the sources. Although the use of some PBDEs is being phased out in some parts of the U.S., this trend may apply to PBDEs as well. We can anticipate that exposure to PBDEs will continue as long as the general public keeps using existing household items such as sofas, mattresses, and carpets that contain PBDEs. This study provides additional information that indoor dust is highly contaminated by persistent and endocrine-disrupting chemicals. PMID:18632138

  17. State Indoor Tanning Laws and Adolescent Indoor Tanning

    PubMed Central

    Guy, Gery P.; Berkowitz, Zahava; Jones, Sherry Everett; O’Malley Olsen, Emily; Miyamoto, Justin N.; Michael, Shannon L.; Saraiya, Mona

    2014-01-01

    Objectives. Recently, several state indoor tanning laws, including age restrictions, were promulgated to reduce indoor tanning among minors. We examined the effects of these laws on adolescent indoor tanning. Methods. We used nationally representative data from the 2009 and 2011 national Youth Risk Behavior Surveys (n = 31 835). Using multivariable logistic regression, we examined the association between state indoor tanning laws and indoor tanning among US high school students. Results. Female students in states with indoor tanning laws were less likely to engage in indoor tanning than those in states without any laws. We observed a stronger association among female students in states with systems access, parental permission, and age restriction laws than among those in states without any laws. We found no significant association among female students in states with only systems access and parental permission laws or among male students. Conclusions. Indoor tanning laws, particularly those including age restrictions, may be effective in reducing indoor tanning among female high school students, for whom rates are the highest. Such reductions have the potential to reduce the health and economic burden of skin cancer. PMID:24524515

  18. Indoor tanning by adolescents: prevalence, practices and policies.

    PubMed

    Lazovich, DeAnn; Forster, Jean

    2005-01-01

    Despite known acute and chronic health effects from the use of indoor tanning, including the potential for all forms of skin cancer, the practice is popular in the United States (US) and Europe. A review of the scientific literature that examines adolescents and indoor tanning use was undertaken, summarising what is known about prevalence and practices among adolescents, characteristics associated with adolescent use, and policies that regulate adolescent access to indoor tanning facilities. The prevalence of indoor tanning is consistently found to be higher among girls than boys and to increase with age in both Europe and the US. An examination of other demographic characteristics, skin cancer risk factors, knowledge, attitudes and social factors points to higher prevalence of the behaviour among adolescents with positive attitudes towards tans and whose friends or parents also tan indoors. Adolescent access to indoor tanning is rarely regulated in the US or Europe, and where regulations exist, business compliance is low. In addition, businesses actively market their product to adolescents as they organise to limit further regulations prohibiting adolescent access. Pricing, licensure, advertising restrictions and media campaigns, in combination with adolescent-targeted interventions, are possible strategies that could be tested for their effectiveness to reduce adolescent indoor tanning use. Harm reduction policies, such as eye protection, that reduce risk for adolescents who choose to tan indoors, are also important.

  19. Indoor Subspacing to Implement Indoorgml for Indoor Navigation

    NASA Astrophysics Data System (ADS)

    Jung, H.; Lee, J.

    2015-10-01

    According to an increasing demand for indoor navigation, there are great attempts to develop applicable indoor network. Representation for a room as a node is not sufficient to apply complex and large buildings. As OGC established IndoorGML, subspacing to partition the space for constructing logical network is introduced. Concerning subspacing for indoor network, transition space like halls or corridors also have to be considered. This study presents the subspacing process for creating an indoor network in shopping mall. Furthermore, categorization of transition space is performed and subspacing of this space is considered. Hall and squares in mall is especially defined for subspacing. Finally, implementation of subspacing process for indoor network is presented.

  20. Impact of indoor surface material on perceived air quality.

    PubMed

    Senitkova, I

    2014-03-01

    The material combination impact on perceived indoor air quality for various surface interior materials is presented in this paper. The chemical analysis and sensory assessments identifies health adverse of indoor air pollutants (TVOCs). In this study, emissions and odors from different common indoor surface materials were investigated in glass test chamber under standardized conditions. Chemical measurements (TVOC concentration) and sensory assessments (odor intensity, air acceptability) were done after building materials exposure to standardized conditions. The results of the chemical and sensory assessment of individual materials and their combinations are compared and discussed within the paper. The using possibility of individual material surface sorption ability was investigated. The knowledge of targeted sorption effects can be used in the interior design phase. The results demonstrate the various sorption abilities of various indoor materials as well as the various sorption abilities of the same indoor material in various combinations. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Residual translation compensations in radar target narrowband imaging based on trajectory information

    NASA Astrophysics Data System (ADS)

    Yue, Wenjue; Peng, Bo; Wei, Xizhang; Li, Xiang; Liao, Dongping

    2018-05-01

    High velocity translation will result in defocusing scattering centers in radar imaging. In this paper, we propose a Residual Translation Compensations (RTC) method based on target trajectory information to eliminate the translation effects in radar imaging. Translation could not be simply regarded as a uniformly accelerated motion in reality. So the prior knowledge of the target trajectory is introduced to enhance compensation precision. First we use the two-body orbit model to figure out the radial distance. Then, stepwise compensations are applied to eliminate residual propagation delay based on conjugate multiplication method. Finally, tomography is used to confirm the validity of the method. Compare with translation parameters estimation method based on the spectral peak of the conjugate multiplied signal, RTC method in this paper enjoys a better tomography result. When the Signal Noise Ratio (SNR) of the radar echo signal is 4dB, the scattering centers can also be extracted clearly.

  2. Indoor residual spraying with a mixture of clothianidin (a neonicotinoid insecticide) and deltamethrin provides improved control and long residual activity against pyrethroid resistant Anopheles gambiae sl in Southern Benin.

    PubMed

    Ngufor, Corine; Fongnikin, Augustin; Rowland, Mark; N'Guessan, Raphael

    2017-01-01

    There is an urgent need for new insecticides for indoor residual spraying (IRS) which can provide improved and prolonged control of malaria vectors that have developed resistance to existing insecticides. The neonicotinoid, clothianidin represents a class of chemistry new to public health. Clothianidin acts as an agonist on nicotinic acetyl choline receptors. IRS with a mixture of Clothianidin and another WHO approved insecticide such as deltamethrin could provide improved control of insecticide resistant malaria vector populations and serve as a tool for insecticide resistance management. The efficacy and residual activity of a novel IRS mixture of deltamethrin and clothianidin was evaluated against wild pyrethroid resistant An. gambiae sl in experimental huts in Cove, Benin. Two application rates of the mixture were tested and comparison was made with clothianidin and deltamethrin applied alone. To assess the residual efficacy of the treatments on different local wall substrates, the inner walls of the experimental huts were covered with either cement, mud or plywood. Clothianidin demonstrated a clear delayed expression in mortality of wild pyrethroid resistant An. gambiae sl in the experimental huts which reached its full effect 120 hours after exposure. Overall mortality over the 12-month hut trial was 15% in the control hut and 24-29% in the deltamethrin-treated huts. The mixture of clothianidin 200mg/m2 and deltamethrin 25mg/m2 induced high overall hut mortality rates (87% on mud walls, 82% on cement walls and 61% on wooden walls) largely due to the clothianidin component and high hut exiting rates (67-76%) mostly due to the deltamethrin component. Mortality rates remained >80% for 8-9 months on mud and cement walls. The residual activity trend was confirmed by results from monthly in situ cone bioassays with laboratory susceptible An. gambiae Kisumu strain. IRS campaigns with the mixture of clothianidin plus deltamethrin have the potential to provide

  3. Indoor residual spraying with a mixture of clothianidin (a neonicotinoid insecticide) and deltamethrin provides improved control and long residual activity against pyrethroid resistant Anopheles gambiae sl in Southern Benin

    PubMed Central

    Fongnikin, Augustin; Rowland, Mark; N’Guessan, Raphael

    2017-01-01

    Introduction There is an urgent need for new insecticides for indoor residual spraying (IRS) which can provide improved and prolonged control of malaria vectors that have developed resistance to existing insecticides. The neonicotinoid, clothianidin represents a class of chemistry new to public health. Clothianidin acts as an agonist on nicotinic acetyl choline receptors. IRS with a mixture of Clothianidin and another WHO approved insecticide such as deltamethrin could provide improved control of insecticide resistant malaria vector populations and serve as a tool for insecticide resistance management. Methods The efficacy and residual activity of a novel IRS mixture of deltamethrin and clothianidin was evaluated against wild pyrethroid resistant An. gambiae sl in experimental huts in Cove, Benin. Two application rates of the mixture were tested and comparison was made with clothianidin and deltamethrin applied alone. To assess the residual efficacy of the treatments on different local wall substrates, the inner walls of the experimental huts were covered with either cement, mud or plywood. Results Clothianidin demonstrated a clear delayed expression in mortality of wild pyrethroid resistant An. gambiae sl in the experimental huts which reached its full effect 120 hours after exposure. Overall mortality over the 12-month hut trial was 15% in the control hut and 24–29% in the deltamethrin-treated huts. The mixture of clothianidin 200mg/m2 and deltamethrin 25mg/m2 induced high overall hut mortality rates (87% on mud walls, 82% on cement walls and 61% on wooden walls) largely due to the clothianidin component and high hut exiting rates (67–76%) mostly due to the deltamethrin component. Mortality rates remained >80% for 8–9 months on mud and cement walls. The residual activity trend was confirmed by results from monthly in situ cone bioassays with laboratory susceptible An. gambiae Kisumu strain. Conclusion IRS campaigns with the mixture of clothianidin plus

  4. Sociocultural experiences, body image, and indoor tanning among young adult women.

    PubMed

    Stapleton, Jerod L; Manne, Sharon L; Greene, Kathryn; Darabos, Katie; Carpenter, Amanda; Hudson, Shawna V; Coups, Elliot J

    2017-10-01

    The purpose of this survey study was to evaluate a model of body image influences on indoor tanning behavior. Participants were 823 young adult women recruited from a probability-based web panel in the United States. Consistent with our hypothesized model, tanning-related sociocultural experiences were indirectly associated with lifetime indoor tanning use and intentions to tan as mediated through tan surveillance and tan dissatisfaction. Findings suggest the need for targeting body image constructs as mechanisms of behavior change in indoor tanning behavioral interventions.

  5. Equal Opportunity, Equal Work: Increasing Women's Participation in the U.S. President's Malaria Initiative Africa Indoor Residual Spraying Project

    PubMed Central

    Donner, Abigail; Belemvire, Allison; Johns, Ben; Mangam, Keith; Fiekowsky, Elana; Gunn, Jayleen; Hayden, Mary; Ernst, Kacey

    2017-01-01

    Background: One of the primary control measures for malaria transmission is indoor residual spraying (IRS). Historically, few women have worked in IRS programs, despite the income-generating potential. Increasing women's roles in IRS requires understanding the barriers to women's participation and implementing measures to address them. The U.S. President's Malaria Initiative (PMI) Africa Indoor Residual Spraying (AIRS) Project is the largest implementer of IRS globally. To address gender inequity in IRS operations, PMI AIRS assessed the barriers to the participation of women and developed and implemented policies to address these barriers. Methods: The PMI AIRS Project initially identified barriers through a series of informal assessments with key stakeholders. PMI AIRS then implemented a series of gender-guided policies, starting in 2015, in Benin, Ethiopia, Ghana, Mali, Madagascar, Mozambique, Rwanda, Senegal, Zambia, and Zimbabwe. The policies included adapting physical work environments to ensure privacy for women; ensuring the safety of women in the workplace; guaranteeing safety and job security of women during pregnancy; and encouraging qualified women to apply for supervisory positions. The project collected routine programmatic data on staff, spray quality, and spray efficiency; data from 2012 through the end of 2015 were analyzed (up through 1 year after implementation of the gender policies). In addition, PMI AIRS conducted surveys in 2015, 2016, and 2017 before and after the spray campaigns in 4 countries to determine changes in gender norms among spray operators through questions about decision making and agency. Results: The PMI AIRS Project increased women's employment with the program. Specifically, women's employment increased overall from 23% in 2012 to 29% in 2015, with a 2015 range from 16% (Mali) to 40% (Madagascar). Growth among supervisor roles was even stronger, with the percentage of women in supervisory roles increasing from 17% in 2012 to

  6. Equal Opportunity, Equal Work: Increasing Women's Participation in the U.S. President's Malaria Initiative Africa Indoor Residual Spraying Project.

    PubMed

    Donner, Abigail; Belemvire, Allison; Johns, Ben; Mangam, Keith; Fiekowsky, Elana; Gunn, Jayleen; Hayden, Mary; Ernst, Kacey

    2017-12-28

    One of the primary control measures for malaria transmission is indoor residual spraying (IRS). Historically, few women have worked in IRS programs, despite the income-generating potential. Increasing women's roles in IRS requires understanding the barriers to women's participation and implementing measures to address them. The U.S. President's Malaria Initiative (PMI) Africa Indoor Residual Spraying (AIRS) Project is the largest implementer of IRS globally. To address gender inequity in IRS operations, PMI AIRS assessed the barriers to the participation of women and developed and implemented policies to address these barriers. The PMI AIRS Project initially identified barriers through a series of informal assessments with key stakeholders. PMI AIRS then implemented a series of gender-guided policies, starting in 2015, in Benin, Ethiopia, Ghana, Mali, Madagascar, Mozambique, Rwanda, Senegal, Zambia, and Zimbabwe. The policies included adapting physical work environments to ensure privacy for women; ensuring the safety of women in the workplace; guaranteeing safety and job security of women during pregnancy; and encouraging qualified women to apply for supervisory positions. The project collected routine programmatic data on staff, spray quality, and spray efficiency; data from 2012 through the end of 2015 were analyzed (up through 1 year after implementation of the gender policies). In addition, PMI AIRS conducted surveys in 2015, 2016, and 2017 before and after the spray campaigns in 4 countries to determine changes in gender norms among spray operators through questions about decision making and agency. The PMI AIRS Project increased women's employment with the program. Specifically, women's employment increased overall from 23% in 2012 to 29% in 2015, with a 2015 range from 16% (Mali) to 40% (Madagascar). Growth among supervisor roles was even stronger, with the percentage of women in supervisory roles increasing from 17% in 2012 to 46% in 2015, with a 2015

  7. Support for indoor tanning policies among young adult women who indoor tan.

    PubMed

    Mays, Darren; Murphy, Sarah E; Bubly, Rachel; Atkins, Michael B; Tercyak, Kenneth P

    2016-12-01

    The purpose of this study to examine support for indoor tanning policies and correlates of policy support among young adult women who indoor tan. Non-Hispanic white women ages 18-30 who indoor tanned in the past year (n = 356, M 23.3 age, SD 3.1) recruited in the Washington, DC area from 2013 to 2016 completed measures of indoor tanning behaviors, attitudes, perceptions, beliefs, and policy support. Most women in the sample supported policies to prevent children under the age of 18 from indoor tanning (74.0 %) and stronger warnings about the risks of indoor tanning on tanning devices (77.6 %); only 10.1 % supported a total ban. In multivariable analyses, support for individual indoor tanning policies varied by demographics (e.g., age), frequent indoor tanning behavior, indoor tanning beliefs, and risk perceptions. Non-Hispanic white young adult women who indoor tan, the primary consumers of indoor tanning, and a high-risk population, largely support indoor tanning prevention policies implemented by many state governments and those currently under review for national enactment. Given low levels of support for a total indoor tanning ban, support for other potential policies (e.g., increasing the minimum age to 21) should be investigated to inform future steps to reduce indoor tanning and the associated health risks.

  8. Resting behaviour of Anopheles stephensi type form to assess its amenability to control malaria through indoor residual spray.

    PubMed

    Nagpal, B N; Srivastava, Aruna; Dash, A P

    2012-09-01

    In the present study, an attempt was made to find reasons of ineffectiveness of indoor residual spray to interrupt malaria transmission by investigating the behaviour of two variants of Anopheles stepnesi, viz. type form and mysorensis in rural areas of Rajasthan, India. Both low malarious (DDT spray from 1958 to 1976) and high malarious (DDT spray from 1958 to April 2006) villages were selected for the study in Arid zone district Jodhpur, Rajasthan during March-April 2006. Resting behaviour of the species during all its movement rhythms covering 24 h period related to: (i) swarming/ mating; (ii) pre- and post-biting rest; (iii) after feed resting between hoping movements; (iv) night and day time resting and; (v) diel activity movements in response to temperature changes, were carried out. The results showed that household objects like cupboards, furnitures, hanging clothes, goods stacked on loft, stored clothes, cobwebs and floor were the dominant resting sites both in sprayed and unsprayed villages. About 95 and 97% of An. stephensi preferred to rest on household objects of unsprayed and sprayed villages respectively. There was no significant difference in resting behaviour of the species in both groups of villages (p >0.05). The pre-biting resting time was recorded as 5 to 15 min whereas post-biting resting time lasted for 15 to 25 min. After biting outdoor (in courtyard--open to sky) species starts entering the rooms at around 2330 hrs. It was observed that during III quarter (0100 to 0400 hrs) maximum species entered into the room were 56% in unsprayed and 62% in sprayed villages. Statistically there was no significant difference in the entry of mosquitoes (p >0.05) in both the groups of villages. Before DDT era, An. stephensi was found resting at all heights of the walls inside the human dwellings. Present study revealed that An. stephensi is trying to avoid sprayable surfaces and tend to rest on unsprayable surfaces during all its movement rhythms starting

  9. Comparison of Insecticide-Treated Nets and Indoor Residual Spraying to Control the Vector of Visceral Leishmaniasis in Mymensingh District, Bangladesh

    PubMed Central

    Chowdhury, Rajib; Dotson, Ellen; Blackstock, Anna J.; McClintock, Shannon; Maheswary, Narayan P.; Faria, Shyla; Islam, Saiful; Akter, Tangin; Kroeger, Axel; Akhter, Shireen; Bern, Caryn

    2011-01-01

    Integrated vector management is a pillar of the South Asian visceral leishmaniasis (VL) elimination program, but the best approach remains a matter of debate. Sand fly seasonality was determined in 40 houses sampled monthly. The impact of interventions on Phlebotomus argentipes density was tested from 2006–2007 in a cluster-randomized trial with four arms: indoor residual spraying (IRS), insecticide-treated nets (ITNs), environmental management (EVM), and no intervention. Phlebotomus argentipes density peaked in March with the highest proportion of gravid females in May. The EVM (mud plastering of wall and floor cracks) showed no impact. The IRS and ITNs were associated with a 70–80% decrease in male and female P. argentipes density up to 5 months post intervention. Vector density rebounded by 11 months post-IRS, whereas ITN-treated households continued to show significantly lower density compared with households without intervention. Our data suggest that both IRS and ITNs may help to improve VL control in Bangladesh. PMID:21540372

  10. Chlorfenapyr (A Pyrrole Insecticide) Applied Alone or as a Mixture with Alpha-Cypermethrin for Indoor Residual Spraying against Pyrethroid Resistant Anopheles gambiae sl: An Experimental Hut Study in Cove, Benin

    PubMed Central

    Ngufor, Corine; Critchley, Jessica; Fagbohoun, Josias; N’Guessan, Raphael; Todjinou, Damien; Rowland, Mark

    2016-01-01

    Background Indoor spraying of walls and ceilings with residual insecticide remains a primary method of malaria control. Insecticide resistance in malaria vectors is a growing problem. Novel insecticides for indoor residual spraying (IRS) which can improve the control of pyrethroid resistant malaria vectors are urgently needed. Insecticide mixtures have the potential to improve efficacy or even to manage resistance in some situations but this possibility remains underexplored experimentally. Chlorfenapyr is a novel pyrrole insecticide which has shown potential to improve the control of mosquitoes which are resistant to current WHO-approved insecticides. Method The efficacy of IRS with chlorfenapyr applied alone or as a mixture with alpha-cypermeththrin (a pyrethroid) was evaluated in experimental huts in Cove, Southern Benin against wild free flying pyrethroid resistant Anopheles gambiae sl. Comparison was made with IRS with alpha-cypermethrin alone. Fortnightly 30-minute in situ cone bioassays were performed to assess the residual efficacy of the insecticides on the treated hut walls. Results Survival rates of wild An gambiae from the Cove hut site in WHO resistance bioassays performed during the trial were >90% with permethrin and deltamethrin treated papers. Mortality of free-flying mosquitoes entering the experimental huts was 4% in the control hut. Mortality with alpha-cypermethrin IRS did not differ from the control (5%, P>0.656). The highest mortality was achieved with chlorfenapyr alone (63%). The alpha-cypermethrin + chlorfenapyr mixture killed fewer mosquitoes than chlorfenapyr alone (43% vs. 63%, P<0.001). While the cone bioassays showed a more rapid decline in residual mortality with chlorfenapyr IRS to <30% after only 2 weeks, fortnightly mortality rates of wild free-flying An gambiae entering the chlorfenapyr IRS huts were consistently high (50–70%) and prolonged, lasting over 4 months. Conclusion IRS with chlorfenapyr shows potential to

  11. Indoor Modelling Benchmark for 3D Geometry Extraction

    NASA Astrophysics Data System (ADS)

    Thomson, C.; Boehm, J.

    2014-06-01

    A combination of faster, cheaper and more accurate hardware, more sophisticated software, and greater industry acceptance have all laid the foundations for an increased desire for accurate 3D parametric models of buildings. Pointclouds are the data source of choice currently with static terrestrial laser scanning the predominant tool for large, dense volume measurement. The current importance of pointclouds as the primary source of real world representation is endorsed by CAD software vendor acquisitions of pointcloud engines in 2011. Both the capture and modelling of indoor environments require great effort in time by the operator (and therefore cost). Automation is seen as a way to aid this by reducing the workload of the user and some commercial packages have appeared that provide automation to some degree. In the data capture phase, advances in indoor mobile mapping systems are speeding up the process, albeit currently with a reduction in accuracy. As a result this paper presents freely accessible pointcloud datasets of two typical areas of a building each captured with two different capture methods and each with an accurate wholly manually created model. These datasets are provided as a benchmark for the research community to gauge the performance and improvements of various techniques for indoor geometry extraction. With this in mind, non-proprietary, interoperable formats are provided such as E57 for the scans and IFC for the reference model. The datasets can be found at: indoor-bench.github.io/indoor-bench"target="_blank">http://indoor-bench.github.io/indoor-bench.

  12. To spray or not to spray? Understanding participation in an indoor residual spray campaign in Arequipa, Peru.

    PubMed

    Paz-Soldán, Valerie A; Bauer, Karin M; Hunter, Gabrielle C; Castillo-Neyra, Ricardo; Arriola, Vanessa D; Rivera-Lanas, Daniel; Rodriguez, Geoffrey H; Toledo Vizcarra, Amparo M; Mollesaca Riveros, Lina M; Levy, Michael Z; Buttenheim, Alison M

    2018-01-01

    Current low participation rates in vector control programmes in Arequipa, Peru complicate the control of Chagas disease. Using focus groups (n = 17 participants) and semi-structured interviews (n = 71) conducted in March and May 2013, respectively, we examined barriers to and motivators of household participation in an indoor residual spray (IRS) campaign that had taken place one year prior in Arequipa. The most common reported barriers to participation were inconvenient spray times due to work obligations, not considering the campaign to be necessary, concerns about secondary health impacts (e.g. allergic reactions to insecticides), and difficulties preparing the home for spraying (e.g. moving heavy furniture). There was also a low perception of risk for contracting Chagas disease that might affect participation. The main motivator to participate was to ensure personal health and well-being. Future IRS campaigns should incorporate more flexible hours, including weekends; provide appropriate educational messages to counter concerns about secondary health effects; incorporate peer educators to increase perceived risk to Chagas in community; obtain support from community members and leaders to build community trust and support for the campaign; and assist individuals in preparing their homes. Enhancing community trust in both the need for the campaign and its operations is key.

  13. To spray or not to spray? Understanding participation in an indoor residual spray campaign in Arequipa, Peru

    PubMed Central

    Bauer, Karin M.; Hunter, Gabrielle C.; Castillo-Neyra, Ricardo; Arriola, Vanessa D.; Rivera-Lanas, Daniel; Rodriguez, Geoffrey H.; Toledo Vizcarra, Amparo M.; Mollesaca Riveros, Lina M.; Levy, Michael Z.; Buttenheim, Alison M.

    2017-01-01

    Current low participation rates in vector control programmes in Arequipa, Peru complicate the control of Chagas disease. Using focus groups (n = 17 participants) and semi-structured interviews (n = 71) conducted in March and May 2013, respectively, we examined barriers to and motivators of household participation in an indoor residual spray (IRS) campaign that had taken place one year prior in Arequipa. The most common reported barriers to participation were inconvenient spray times due to work obligations, not considering the campaign to be necessary, concerns about secondary health impacts (e.g. allergic reactions to insecticides), and difficulties preparing the home for spraying (e.g. moving heavy furniture). There was also a low perception of risk for contracting Chagas disease that might affect participation. The main motivator to participate was to ensure personal health and well-being. Future IRS campaigns should incorporate more flexible hours, including weekends; provide appropriate educational messages to counter concerns about secondary health effects; incorporate peer educators to increase perceived risk to Chagas in community; obtain support from community members and leaders to build community trust and support for the campaign; and assist individuals in preparing their homes. Enhancing community trust in both the need for the campaign and its operations is key. PMID:27189446

  14. Indoor tanning and risk of early-onset basal cell carcinoma

    PubMed Central

    Ferrucci, Leah M.; Cartmel, Brenda; Molinaro, Annette M.; Leffell, David J.; Bale, Allen E.; Mayne, Susan T.

    2011-01-01

    Background Despite a rise in incidence of basal cell carcinoma (BCC) among young people and the ubiquity of indoor tanning in this population, few epidemiologic studies have investigated this exposure-disease relationship. Objective Evaluate the association between indoor tanning and early-onset BCC. Methods BCC cases (n=376) and controls with minor benign skin conditions (n=390) under age 40 were identified through Yale Dermatopathology. Participants provided information on ever indoor tanning, age of initiation, frequency, duration, burns while tanning, and type of tanning device during an in-person interview. We calculated odds ratios (OR) and 95% confidence intervals (CI) using multivariate logistic regression with never indoor tanners as the referent group. Results Ever indoor tanning was associated with a 69% increased risk of early-onset BCC (95% CI=1.15-2.48). This association was stronger among women (OR=2.14, 95% CI=1.31-3.47), for multiple BCCs (OR=2.16, 95% CI=1.26-3.70), and for BCCs on the trunk and extremities (OR=2.81, 95% CI=1.57-5.02). Risk increased dose-dependently with years used regular indoor tanning devices (p-trend=0.003), number of overall burns (p-trend=<0.001) and burns to biopsy site (p-trend=<0.001) from indoor tanning. Approximately one-quarter (27%) of early-onset BCCs (or 43% among women) could be prevented if individuals never tanned indoors. Limitations Potential recall bias of indoor tanning by cases and generalizability of the control population suggest replication in other studies is warranted. Conclusions Indoor tanning was a strong risk factor for early-onset BCC, particularly among women. Indoor tanning should continue to be targeted by both policy-based and behavioral interventions, as the impact on BCC-associated morbidity may be substantial. PMID:22153793

  15. Good performances but short lasting efficacy of Actellic 50 EC Indoor Residual Spraying (IRS) on malaria transmission in Benin, West Africa

    PubMed Central

    2014-01-01

    Background The National Malaria Control Program (NMCP) has been using pirimiphos methyl for the first time for indoor residual spraying (IRS) in Benin. The first round was a success with a significant decrease of entomological indicators of malaria transmission in the treated districts. We present the results of the entomological impact on malaria transmission. Entomologic parameters in the control area were compared with those in intervention sites. Methods Mosquito collections were carried out in three districts in the Atacora-Dongo region of which two were treated with pirimiphos methyl (Actellic 50EC) (Tanguiéta and Kouandé) and the untreated (Copargo) served as control. Anopheles gambiae s.l. populations were sampled monthly by human landing catch. In addition, window exit traps and pyrethrum spray catches were performed to assess exophagic behavior of Anopheles vectors. In the three districts, mosquito collections were organized to follow the impact of pirimiphos methyl IRS on malaria transmission and possible changes in the behavior of mosquitoes. The residual activity of pirimiphos methyl in the treated walls was also assessed using WHO bioassay test. Results A significant reduction (94.25%) in human biting rate was recorded in treated districts where an inhabitant received less than 1 bite of An. gambiae per night. During this same time, the entomological inoculation rate (EIR) dramatically declined in the treated area (99.24% reduction). We also noted a significant reduction in longevity of the vectors and an increase in exophily induced by pirimiphos methyl on An. gambiae. However, no significant impact was found on the blood feeding rate. Otherwise, the low residual activity of Actellic 50 EC, which is three months, is a disadvantage. Conclusion Pirimiphos methyl was found to be effective for IRS in Benin. However, because of the low persistence of Actellic 50EC used in this study on the treated walls, the recourse to another more residual formulation

  16. Predictors of Plasma DDT and DDE Concentrations among Women Exposed to Indoor Residual Spraying for Malaria Control in the South African Study of Women and Babies (SOWB)

    PubMed Central

    Bornman, Riana M.S.; Archer, Janet I.; Kudumu, Mwenda O.; Travlos, Gregory S.; Wilson, Ralph E.; Longnecker, Matthew P.

    2014-01-01

    regarding home preparations may provide an interventional target. Citation: Whitworth KW, Bornman RM, Archer JI, Kudumu MO, Travlos GS, Wilson RE, Longnecker MP. 2014. Predictors of plasma DDT and DDE concentrations among women exposed to indoor residual spraying for malaria control in the South African Study of Women and Babies (SOWB). Environ Health Perspect 122:545–552; http://dx.doi.org/10.1289/ehp.1307025 PMID:24577839

  17. Contribution of indoor and outdoor nitrogen dioxide to indoor air quality of wayside shops.

    PubMed

    Shuai, Jianfei; Yang, Wonho; Ahn, Hogi; Kim, Sunshin; Lee, Seokyong; Yoon, Sung-Uk

    2013-06-01

    Indoor nitrogen dioxide (NO₂) concentration is an important factor for personal exposure despite the wide distribution of its sources. Exposure to NO₂ may produce adverse health effects. The aims of this study were to characterize the indoor air quality of wayside shops using multiple NO₂ measurements, and to estimate the contribution of outdoor NO₂ sources such as vehicle emission to indoor air quality. Daily indoor and outdoor NO₂ concentrations were measured for 21 consecutive days in wayside shops (5 convenience stores, 5 coffee shops, and 5 restaurants). Contributions of outdoor NO₂ sources to indoor air quality were calculated with penetration factors and source strength factors by indoor mass balance model in winter and summer, respectively. Most wayside shops had significant differences in indoor and outdoor NO₂ concentrations both in winter and in summer. Indoor NO₂ concentrations in restaurants were twice more than those in convenience stores and coffee shops in winter. While outdoor NO₂ contributions in indoor convenience stores and coffee shops were dominant, indoor NO₂ contributions were dominant in restaurants. These could be explained that indoor NO₂ sources such as gas range and smoking mainly affect indoor concentrations comparing to outdoor sources such as vehicle emission. The indoor mass balance model by multiple measurements suggests that quantitative contribution of outdoor air on indoor air quality might be estimated without measurements of ventilation, indoor generation and decay rate.

  18. Evaluating the feasibility of using insecticide quantification kits (IQK) for estimating cyanopyrethroid levels for indoor residual spraying in Vanuatu

    PubMed Central

    2014-01-01

    Background The quality of routine indoor residual spraying (IRS) operations is rarely assessed because of the limited choice of methods available for quantifying insecticide content in the field. This study, therefore, evaluated a user-friendly, rapid colorimetric assay for detecting insecticide content after routine IRS operations were conducted. Methods This study was conducted in Tafea Province, Vanuatu. Routine IRS was conducted with lambda cyhalothrin. Two methods were used to quantify the IRS activities: 1) pre-spray application of small felt pads and 2) post-spray removal of insecticide with adhesive. The insecticide content was quantified using a colorimetric assay (Insecticide Quantification Kit [IQK]), which involved exposing each sample to the test reagents for 15 mins. The concentration of insecticide was indicated by the depth of red colour. Results The IQK proved simple to perform in the field and results could be immediately interpreted by the programme staff. The insecticide content was successfully sampled by attaching felt pads to the house walls prior to spraying. The IRS operation was well conducted, with 83% of houses being sprayed at the target dose (20 – 30 mg AI/m2). The average reading across all houses was 24.4 ± 1.5 mg AI/m2. The results from the felt pads applied pre-spray were used as a base to compare methods for sampling insecticide from walls post-spray. The adhesive of Sellotape did not collect adequate samples. However, the adhesive of the felt pads provided accurate samples of the insecticide content on walls. Conclusion The IQK colorimetric assay proved to be a useful tool that was simple to use under realistic field conditions. The assay provided rapid information on IRS spray dynamics and spray team performance, facilitating timely decision making and reporting for programme managers. The IQK colorimetric assay will have direct applications for routine quality control in malaria control programmes globally and has the

  19. A comparative cost analysis of insecticide-treated nets and indoor residual spraying in highland Kenya.

    PubMed

    Guyatt, H L; Kinnear, J; Burini, M; Snow, R W

    2002-06-01

    The relative cost of indoor residual house-spraying (IRS) versus insecticide-treated bednets (ITNs) forms part of decisions regarding selective malaria prevention. This paper presents a cost comparison of these two approaches as recently implemented by Merlin, a UK emergency relief organization funded through international donor support and working in the highland districts of Gucha and Kisii in Kenya. The financial costs (cash expenditures) and the economic costs (including the opportunity costs of using existing staff and volunteers, and an annualized cost for capital items) were assessed. The financial cost for IRS was US dollars 0.86 per person protected, compared with 4.21 dollars for ITNs (reducing to 3.42 dollars to the provider assuming cost recovery). The economic cost per person protected for IRS was 0.88 dollars, compared with 2.34 dollars for ITNs. The costs for ITNs were sensitive to the number of nets sold per community group ('efficiency'), as the delivery costs constituted upwards of 40% of the total cost. However, even marked increases in efficiency of these groups could not reduce the costs of ITNs to that comparable with IRS, except if more than one cycle of IRS was needed. The implications of predicted reductions in the cost of insecticide for both IRS and ITNs are also explored. The provision of itemized cost data allows predictions to be made on changes in the design of these programmes. Under almost all design scenarios, IRS would appear to be a more cost-efficient means of vector control in the Kenyan highlands.

  20. Taking local ownership: government and household contribution to indoor residual spraying in Zanzibar and mainland Tanzania.

    PubMed

    Alidina, Zainab; Colaco, Rajeev; Ali, Abdullah S; Mcha, Juma H; Mwalimu, Charles D; Thawer, Narjis G; Lalji, Shabbir; Mutagahywa, Joshua; Ramsan, Mahdi M; Kafuko, Jessica M; Kaspar, Naomi; Magesa, Stephen M; Reithinger, Richard; Ngondi, Jeremiah M

    2016-07-01

    While donor funding is instrumental in initiation and implementation of malaria control efforts, national government contributions are key to local ownership and sustainability. This study explored in-kind contributions of local government and households towards the cost of indoor residual spraying (IRS) interventions in Tanzania. Data were collected through interviews with local government officials and technical teams in the IRS project. Household contribution was based on provision of water for IRS. Government contributions included government-provided warehouse and office space, vehicles, and staff labour. In-kind contributions were aggregated at the district, regional and national level. Calculations were based on proportion of total costs of IRS from 2010 to 2012. The mainland government provided larger amounts of in-kind contribution in absolute value (mean of US$454 200) compared to Zanzibar (US$89 163). On average, in-kind contribution was 5.5% of total costs in Zanzibar and 2.9% in mainland. The proportion of government in-kind contribution was higher in Zanzibar versus the mainland (86% vs 50%) while household contribution was higher in mainland compared to Zanzibar (50% vs 14%). Government involvement, particularly through budgetary allocations and increased in-kind contribution, needs to be encouraged for malaria control efforts to be locally owned, managed and sustained. © The Author 2015. Published by Oxford University Press on behalf of Royal Society of Tropical Medicine and Hygiene. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  1. A View Indoors, Indoor Environment Division's e-Article Series

    EPA Pesticide Factsheets

    The Indoor Environments Division has created partnership with public and private sector entities to help encourage the public to take action to minimize their risk and mitigate indoor air quality problems.

  2. Indoor Air vs. Indoor Construction: A New Beginning.

    ERIC Educational Resources Information Center

    Manicone, Santo

    2000-01-01

    Identifies the steps that can be taken to lessen the impact of indoor air pollution created from indoor renovation projects, including project management tips to help contractors avoid creating unnecessary air pollution. Final comments address air pollution control when installing new furniture, smoking restrictions, occupant relations, and the…

  3. Indoor calibration for stereoscopic camera STC: a new method

    NASA Astrophysics Data System (ADS)

    Simioni, E.; Re, C.; Da Deppo, V.; Naletto, G.; Borrelli, D.; Dami, M.; Ficai Veltroni, I.; Cremonese, G.

    2017-11-01

    In the framework of the ESA-JAXA BepiColombo mission to Mercury, the global mapping of the planet will be performed by the on-board Stereo Camera (STC), part of the SIMBIO-SYS suite [1]. In this paper we propose a new technique for the validation of the 3D reconstruction of planetary surface from images acquired with a stereo camera. STC will provide a three-dimensional reconstruction of Mercury surface. The generation of a DTM of the observed features is based on the processing of the acquired images and on the knowledge of the intrinsic and extrinsic parameters of the optical system. The new stereo concept developed for STC needs a pre-flight verification of the actual capabilities to obtain elevation information from stereo couples: for this, a stereo validation setup to get an indoor reproduction of the flight observing condition of the instrument would give a much greater confidence to the developed instrument design. STC is the first stereo satellite camera with two optical channels converging in a unique sensor. Its optical model is based on a brand new concept to minimize mass and volume and to allow push-frame imaging. This model imposed to define a new calibration pipeline to test the reconstruction method in a controlled ambient. An ad-hoc indoor set-up has been realized for validating the instrument designed to operate in deep space, i.e. in-flight STC will have to deal with source/target essentially placed at infinity. This auxiliary indoor setup permits on one side to rescale the stereo reconstruction problem from the operative distance in-flight of 400 km to almost 1 meter in lab; on the other side it allows to replicate different viewing angles for the considered targets. Neglecting for sake of simplicity the Mercury curvature, the STC observing geometry of the same portion of the planet surface at periherm corresponds to a rotation of the spacecraft (SC) around the observed target by twice the 20° separation of each channel with respect to nadir

  4. Indoor Calibration for Stereoscopic Camera STC, A New Method

    NASA Astrophysics Data System (ADS)

    Simioni, E.; Re, C.; Da Deppo, V.; Naletto, G.; Borrelli, D.; Dami, M.; Ficai Veltroni, I.; Cremonese, G.

    2014-10-01

    In the framework of the ESA-JAXA BepiColombo mission to Mercury, the global mapping of the planet will be performed by the on-board Stereo Camera (STC), part of the SIMBIO-SYS suite [1]. In this paper we propose a new technique for the validation of the 3D reconstruction of planetary surface from images acquired with a stereo camera. STC will provide a three-dimensional reconstruction of Mercury surface. The generation of a DTM of the observed features is based on the processing of the acquired images and on the knowledge of the intrinsic and extrinsic parameters of the optical system. The new stereo concept developed for STC needs a pre-flight verification of the actual capabilities to obtain elevation information from stereo couples: for this, a stereo validation setup to get an indoor reproduction of the flight observing condition of the instrument would give a much greater confidence to the developed instrument design. STC is the first stereo satellite camera with two optical channels converging in a unique sensor. Its optical model is based on a brand new concept to minimize mass and volume and to allow push-frame imaging. This model imposed to define a new calibration pipeline to test the reconstruction method in a controlled ambient. An ad-hoc indoor set-up has been realized for validating the instrument designed to operate in deep space, i.e. in-flight STC will have to deal with source/target essentially placed at infinity. This auxiliary indoor setup permits on one side to rescale the stereo reconstruction problem from the operative distance in-flight of 400 km to almost 1 meter in lab; on the other side it allows to replicate different viewing angles for the considered targets. Neglecting for sake of simplicity the Mercury curvature, the STC observing geometry of the same portion of the planet surface at periherm corresponds to a rotation of the spacecraft (SC) around the observed target by twice the 20° separation of each channel with respect to nadir

  5. Assessing indoor air quality in New York City nail salons.

    PubMed

    Pavilonis, Brian; Roelofs, Cora; Blair, Carly

    2018-05-01

    Nail salons are an important business and employment sector for recent immigrants offering popular services to a diverse range of customers across the United States. However, due to the nature of nail products and services, salon air can be burdened with a mix of low levels of hazardous airborne contaminants. Surveys of nail technicians have commonly found increased work-related symptoms, such as headaches and respiratory irritation, that are consistent with indoor air quality problems. In an effort to improve indoor air quality in nail salons, the state of New York recently promulgated regulations to require increased outdoor air and "source capture" of contaminants. Existing indoor air quality in New York State salons is unknown. In advance of the full implementation of the rules by 2021, we sought to establish reliable and usable baseline indoor air quality metrics to determine the feasibility and effectiveness of the requirement. In this pilot study, we measured total volatile organic compounds (TVOC) and carbon dioxide (CO 2 ) concentrations in 10 nail salons located in New York City to assess temporal and spatial trends. Within salon contaminant variation was generally minimal, indicating a well-mixed room and similar general exposure despite the task being performed. TVOC and CO 2 concentrations were strongly positively correlated (ρ = 0.81; p < 0.01) suggesting that CO 2 measurements could potentially be used to provide an initial determination of acceptable indoor air quality for the purposes of compliance with the standard. An almost tenfold increase in TVOC concentration was observed when the American National Standards Institute/American Society of Heating, Refrigerating and Air-Conditioning Engineers (ANSI/ASHRAE) target CO 2 concentration of 850 ppm was exceeded compared to when this target was met.

  6. Indoor Tanning

    MedlinePlus

    ... proof that indoor tanning is safer than tanning outdoors. Indoor tanning systems give concentrated UV exposure regardless ... For example, it’s essential for promoting good bone health. While UV ... a tan to get that benefit. According to the Surgeon General, fair and light- ...

  7. The Economic Value of Long-Lasting Insecticidal Nets and Indoor Residual Spraying Implementation in Mozambique

    PubMed Central

    Lee, Bruce Y.; Bartsch, Sarah M.; Stone, Nathan T. B.; Zhang, Shufang; Brown, Shawn T.; Chatterjee, Chandrani; DePasse, Jay V.; Zenkov, Eli; Briët, Olivier J. T.; Mendis, Chandana; Viisainen, Kirsi; Candrinho, Baltazar; Colborn, James

    2017-01-01

    Malaria-endemic countries have to decide how much of their limited resources for vector control to allocate toward implementing long-lasting insecticidal nets (LLINs) versus indoor residual spraying (IRS). To help the Mozambique Ministry of Health use an evidence-based approach to determine funding allocation toward various malaria control strategies, the Global Fund convened the Mozambique Modeling Working Group which then used JANUS, a software platform that includes integrated computational economic, operational, and clinical outcome models that can link with different transmission models (in this case, OpenMalaria) to determine the economic value of vector control strategies. Any increase in LLINs (from 80% baseline coverage) or IRS (from 80% baseline coverage) would be cost-effective (incremental cost-effectiveness ratios ≤ $114/disability-adjusted life year averted). However, LLIN coverage increases tend to be more cost-effective than similar IRS coverage increases, except where both pyrethroid resistance is high and LLIN usage is low. In high-transmission northern regions, increasing LLIN coverage would be more cost-effective than increasing IRS coverage. In medium-transmission central regions, changing from LLINs to IRS would be more costly and less effective. In low-transmission southern regions, LLINs were more costly and less effective than IRS, due to low LLIN usage. In regions where LLINs are more cost-effective than IRS, it is worth considering prioritizing LLIN coverage and use. However, IRS may have an important role in insecticide resistance management and epidemic control. Malaria intervention campaigns are not a one-size-fits-all solution, and tailored approaches are necessary to account for the heterogeneity of malaria epidemiology. PMID:28719286

  8. The Economic Value of Long-Lasting Insecticidal Nets and Indoor Residual Spraying Implementation in Mozambique.

    PubMed

    Lee, Bruce Y; Bartsch, Sarah M; Stone, Nathan T B; Zhang, Shufang; Brown, Shawn T; Chatterjee, Chandrani; DePasse, Jay V; Zenkov, Eli; Briët, Olivier J T; Mendis, Chandana; Viisainen, Kirsi; Candrinho, Baltazar; Colborn, James

    2017-06-01

    AbstractMalaria-endemic countries have to decide how much of their limited resources for vector control to allocate toward implementing long-lasting insecticidal nets (LLINs) versus indoor residual spraying (IRS). To help the Mozambique Ministry of Health use an evidence-based approach to determine funding allocation toward various malaria control strategies, the Global Fund convened the Mozambique Modeling Working Group which then used JANUS, a software platform that includes integrated computational economic, operational, and clinical outcome models that can link with different transmission models (in this case, OpenMalaria) to determine the economic value of vector control strategies. Any increase in LLINs (from 80% baseline coverage) or IRS (from 80% baseline coverage) would be cost-effective (incremental cost-effectiveness ratios ≤ $114/disability-adjusted life year averted). However, LLIN coverage increases tend to be more cost-effective than similar IRS coverage increases, except where both pyrethroid resistance is high and LLIN usage is low. In high-transmission northern regions, increasing LLIN coverage would be more cost-effective than increasing IRS coverage. In medium-transmission central regions, changing from LLINs to IRS would be more costly and less effective. In low-transmission southern regions, LLINs were more costly and less effective than IRS, due to low LLIN usage. In regions where LLINs are more cost-effective than IRS, it is worth considering prioritizing LLIN coverage and use. However, IRS may have an important role in insecticide resistance management and epidemic control. Malaria intervention campaigns are not a one-size-fits-all solution, and tailored approaches are necessary to account for the heterogeneity of malaria epidemiology.

  9. Pyrethroid pesticide residues in the global environment: An overview.

    PubMed

    Tang, Wangxin; Wang, Di; Wang, Jiaqi; Wu, Zhengwen; Li, Lingyu; Huang, Mingli; Xu, Shaohui; Yan, Dongyun

    2018-01-01

    Pyrethroids are synthetic organic insecticides with low mammalian toxicity that are widely used in both rural and urban areas worldwide. After entering the natural environment, pyrethroids circulate among the three phases of solid, liquid, and gas and enter organisms through food chains, resulting in substantial health risks. This review summarized the available studies on pyrethroid residues since 1986 in different media at the global scale and indicated that pyrethroids have been widely detected in a range of environments (including soils, water, sediments, and indoors) and in organisms. The concentrations and detection rates of agricultural pyrethroids, which always contain α-cyanogroup (α-CN), such as cypermethrin and fenvalerate, decline in the order of crops > sediments > soils > water. Urban pyrethroids (not contain α-CN), such as permethrin, have been detected at high levels in the indoor environment, and 3-phenoxybenzoic acid, a common pyrethroid metabolite in human urine, is frequently detected in the human body. Pyrethroid pesticides accumulate in sediments, which are a source of pyrethroid residues in aquatic products. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Impact of Indoor Residual Spraying of Lambda-Cyhalothrin on Malaria Prevalence and Anemia in an Epidemic-Prone District of Muleba, North-Western Tanzania

    PubMed Central

    Mashauri, Fabian M.; Kinung'hi, Safari M.; Kaatano, Godfrey M.; Magesa, Stephen M.; Kishamawe, Coleman; Mwanga, Joseph R.; Nnko, Soori E.; Malima, Robert C.; Mero, Chacha N.; Mboera, Leonard E. G.

    2013-01-01

    The Government of Tanzania introduced indoor residual spraying (IRS) in Muleba district in north-western Tanzania after frequent malaria epidemics. Malaria parasitological baseline and two cross-sectional follow-up surveys were conducted in villages under the IRS program and those not under IRS to assess the impact of IRS intervention. After two rounds of IRS intervention there was a significant reduction of malaria parasitological indices in both two villages. In IRS villages overall, parasitemia prevalence was reduced by 67.2%, splenomegaly was reduced by 75.8%, whereas anemia was reduced by 50.5%. There was also a decline of malaria parasite density from 896.4 at baseline to 128.8 at second follow-up survey. Similarly, there was also a reduction of malaria parasitological indices in non-IRS villages; however, parasitological indices in IRS villages remained far below the levels in non-IRS villages. The reduction of malaria parasitological indices in non-IRS villages might have been contributed by interventions other than IRS. PMID:23458959

  11. Airborne particle-bound brominated flame retardants: Levels, size distribution and indoor-outdoor exchange.

    PubMed

    Zhu, Yue-Shan; Yang, Wan-Dong; Li, Xiu-Wen; Ni, Hong-Gang; Zeng, Hui

    2018-02-01

    The quality of indoor environments has a significant impact on public health. Usually, an indoor environment is treated as a static box, in which physicochemical reactions of indoor air contaminants are negligible. This results in conservative estimates for primary indoor air pollutant concentrations, while also ignoring secondary pollutants. Thus, understanding the relationship between indoor and outdoor particles and particle-bound pollutants is of great significance. For this reason, we collected simultaneous indoor and outdoor measurements of the size distribution of airborne brominated flame retardant (BFR) congeners. The time-dependent concentrations of indoor particles and particle-bound BFRs were then estimated with the mass balance model, accounting for the outdoor concentration, indoor source strength, infiltration, penetration, deposition and indoor resuspension. Based on qualitative observation, the size distributions of ΣPBDE and ΣHBCD were characterized by bimodal peaks. According to our results, particle-bound BDE209 and γ-HBCD underwent degradation. Regardless of the surface adsorption capability of particles and the physicochemical properties of the target compounds, the concentration of BFRs in particles of different size fractions seemed to be governed by the particle distribution. Based on our estimations, for airborne particles and particle-bound BFRs, a window-open ventilated room only takes a quarter of the time to reach an equilibrium between the concentration of pollutants inside and outside compared to a closed room. Unfortunately, indoor pollutants and outdoor pollutants always exist simultaneously, which poses a window-open-or-closed dilemma to achieve proper ventilation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Alternative Methods for Assessing Contaminant Transport from the Vadose Zone to Indoor Air

    NASA Astrophysics Data System (ADS)

    Baylor, K. J.; Lee, A.; Reddy, P.; Plate, M.

    2010-12-01

    Vapor intrusion, which is the transport of contaminant vapors from groundwater and the vadose zone to indoor air, has emerged as a significant human health risk near hazardous waste sites. Volatile organic compounds (VOCs) such as trichloroethylene (TCE) and tetrachloroethylene (PCE) can volatilize from groundwater and from residual sources in the vadose zone and enter homes and commercial buildings through cracks in the slab, plumbing conduits, or other preferential pathways. Assessment of the vapor intrusion pathway typically requires collection of groundwater, soil gas, and indoor air samples, a process which can be expensive and time-consuming. We evaluated three alternative vapor intrusion assessment methods, including 1) use of radon as a surrogate for vapor intrusion, 2) use of pressure differential measurements between indoor/outdoor and indoor/subslab to assess the potential for vapor intrusion, and 3) use of passive, longer-duration sorbent methods to measure indoor air VOC concentrations. The primary test site, located approximately 30 miles south of San Francisco, was selected due to the presence of TCE (10 - 300 ug/L) in shallow groundwater (5 to 10 feet bgs). At this test site, we found that radon was not a suitable surrogate to asses vapor intrusion and that pressure differential measurements are challenging to implement and equipment-intensive. More significantly, we found that the passive, longer-duration sorbent methods are easy to deploy and compared well quantitatively with standard indoor air sampling methods. The sorbent technique is less than half the cost of typical indoor air methods, and also provides a longer duration sample, typically 3 to 14 days rather than 8 to 24 hours for standard methods. The passive sorbent methods can be a reliable, cost-effective, and easy way to sample for TCE, PCE and other VOCs as part of a vapor intrusion investigation.

  13. Randomized controlled trial of a web-based indoor tanning intervention: Acceptability and preliminary outcomes.

    PubMed

    Stapleton, Jerod L; Manne, Sharon L; Darabos, Katie; Greene, Kathryn; Ray, Anne E; Turner, Amber L; Coups, Elliot J

    2015-12-01

    This article describes the acceptability and preliminary behavioral outcomes of a pilot randomized control trial of a web-based indoor tanning intervention for young adult women. The intervention targets indoor tanning users' perceptions of the benefits and value of tanning and addresses the role of body image-related constructs in indoor tanning. Participants were 186 young adult women who reported indoor tanning at least once in the past 12 months. The study design was a 2-arm randomized controlled trial with pre- and postintervention assessments and random assignment to an intervention or control condition. Intervention acceptability was assessed by obtaining participants' evaluation of the intervention. Regression analyses were used to test for intervention condition differences in preliminary behavioral outcomes measured at 6 weeks postintervention. Participants provided favorable evaluations of the intervention on several dimensions and a highly positive overall rating. Intervention participants were more likely to report abstaining from indoor tanning and indicated a lower likelihood of using indoor tanning in the future compared with control participants on the postintervention assessment. No differences were found for sunburns. The results of this pilot randomized controlled trial provide evidence that the indoor tanning intervention is acceptable to participants and may encourage cessation of indoor tanning behavior. The findings provide preliminary support for an indoor tanning intervention that engages tanners to challenge their beliefs about the benefits of indoor tanning. The use of a web-based indoor tanning intervention is unique and provides strong potential for dissemination. (PsycINFO Database Record (c) 2015 APA, all rights reserved).

  14. Indoor air pollution in slum neighbourhoods of Addis Ababa, Ethiopia

    NASA Astrophysics Data System (ADS)

    Sanbata, Habtamu; Asfaw, Araya; Kumie, Abera

    2014-06-01

    An estimated 95% of the population of Ethiopia uses traditional biomass fuels, such as wood, dung, charcoal, or crop residues, to meet household energy needs. As a result of the harmful smoke emitted from the combustion of biomass fuels, indoor air pollution is responsible for more than 50,000 deaths annually and causes nearly 5% of the burden of disease in Ethiopia. Very limited research on indoor air pollution and its health impacts exists in Ethiopia. This study was, therefore, undertaken to assess the magnitude of indoor air pollution from household fuel use in Addis Ababa, the capital city of Ethiopia. During January and February, 2012, the concentration of fine particulate matter (PM2.5) in 59 households was measured using the University of California at Berkeley Particle Monitor (UCB PM). The raw data was analysed using Statistical Package of Social Science (SPSS version 20.0) software to determine variance between groups and descriptive statistics. The geometric mean of 24-h indoor PM2.5 concentration is approximately 818 μg m-3 (Standard deviation (SD = 3.61)). The highest 24-h geometric mean of PM2.5 concentration observed were 1134 μg m-3 (SD = 3.36), 637 μg m-3 (SD = 4.44), and 335 μg m-3 (SD = 2.51), respectively, in households using predominantly solid fuel, kerosene, and clean fuel. Although 24-h mean PM2.5 concentration between fuel types differed statistically (P < 0.05), post hoc pairwise comparison indicated no significant difference in mean concentration of PM2.5 between improved biomass stoves and traditional stoves (P > 0.05). The study revealed indoor air pollution is a major environmental and health hazard from home using biomass fuel in Addis Ababa. The use of clean fuels and efficient cooking stoves is recommended.

  15. Polycyclic aromatic hydrocarbons and their derivatives in indoor and outdoor air in an eight-home study

    NASA Astrophysics Data System (ADS)

    Chuang, Jane C.; Mack, Gregory A.; Kuhlman, Michael R.; Wilson, Nancy K.

    A pilot field study was performed in Columbus, OH, during the winter of 1986/1987. The objectives were to determine the feasibility of the use of a newly developed quiet sampler in indoor air sampling for particles and semivolatile organic compounds (SVOC) and to measure the concentrations of polycyclic aromatic hydrocarbons (PAH), PAH derivatives, and nicotine in air in selected residences. Eight homes were chosen for sampling on the basis of these characteristics: electric/gas heating system, electric/gas cooking appliances, and the absence/presence of environmental tobacco smoke (ETS). The indoor sampler was equipped with a quartz-fiber filter to collect particles followed by XAD-4 resin to trap SVOC. A PS-1 sampler with a similar sampling module was used outdoors. The indoor air was sampled in the kitchen and living room areas over two consecutive 8-h periods. The outdoor air was sampled concurrently with the indoor samples over a 16-h period. Fifteen PAH, five nitro-PAH, five oxygenated PAH, and three nitrogen heterocyclic compounds were determined in these samples. The most abundant PAH found indoors was naphthalene. The indoor concentrations of PAH derivatives were lower than those of their parent compounds. Average concentrations of all but three target compounds (naphthalene dicarboxylic acid anhydride, pyrene dicarboxylic acid anhydride, and 2-nitrofluoranthene) were higher indoors than outdoors. Environmental tobacco smoke was the most significant influence on indoor pollutant levels. Homes with gas heating systems had higher indoor pollutant levels than homes with electric heating systems. However, the true effects of heating and cooking systems were not characterized as accurately as the effects of ETS because of the small sample sizes and the lack of statistical significance for most pollutant differences in the absence of ETS. The concentrations of PAH marker compounds (phenanthrene, fluoranthene, and pyrene) correlated well with the concentrations

  16. Evolution of the indoor biome.

    PubMed

    Martin, Laura J; Adams, Rachel I; Bateman, Ashley; Bik, Holly M; Hawks, John; Hird, Sarah M; Hughes, David; Kembel, Steven W; Kinney, Kerry; Kolokotronis, Sergios-Orestis; Levy, Gabriel; McClain, Craig; Meadow, James F; Medina, Raul F; Mhuireach, Gwynne; Moreau, Corrie S; Munshi-South, Jason; Nichols, Lauren M; Palmer, Clare; Popova, Laura; Schal, Coby; Täubel, Martin; Trautwein, Michelle; Ugalde, Juan A; Dunn, Robert R

    2015-04-01

    Few biologists have studied the evolutionary processes at work in indoor environments. Yet indoor environments comprise approximately 0.5% of ice-free land area--an area as large as the subtropical coniferous forest biome. Here we review the emerging subfield of 'indoor biome' studies. After defining the indoor biome and tracing its deep history, we discuss some of its evolutionary dimensions. We restrict our examples to the species found in human houses--a subset of the environments constituting the indoor biome--and offer preliminary hypotheses to advance the study of indoor evolution. Studies of the indoor biome are situated at the intersection of evolutionary ecology, anthropology, architecture, and human ecology and are well suited for citizen science projects, public outreach, and large-scale international collaborations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Multi-country assessment of residual bio-efficacy of insecticides used for indoor residual spraying in malaria control on different surface types: results from program monitoring in 17 PMI/USAID-supported IRS countries.

    PubMed

    Dengela, Dereje; Seyoum, Aklilu; Lucas, Bradford; Johns, Benjamin; George, Kristen; Belemvire, Allison; Caranci, Angela; Norris, Laura C; Fornadel, Christen M

    2018-01-30

    Indoor residual spraying (IRS) is the application of insecticide to the interior walls of household structures that often serve as resting sites for mosquito vectors of malaria. Human exposure to malaria vectors is reduced when IRS involves proper application of pre-determined concentrations of the active ingredient specific to the insecticide formulation of choice. The impact of IRS can be affected by the dosage of insecticide, spray coverage, vector behavior, vector susceptibility to insecticides, and the residual efficacy of the insecticide applied. This report compiles data on the residual efficacy of insecticides used in IRS campaigns implemented by the United States President's Malaria Initiative (PMI)/United States Agency for International Development (USAID) in 17 African countries and compares observed length of efficacy to ranges proposed in World Health Organization (WHO) guidelines. Additionally, this study provides initial analysis on variation of mosquito mortality depending on the surface material of sprayed structures, country spray program, year of implementation, source of tested mosquitoes, and type of insecticide. Residual efficacy of the insecticides used for PMI/USAID-supported IRS campaigns was measured in Benin, Burkina Faso, Ethiopia, Ghana, Kenya, Liberia, Madagascar, Malawi, Mali, Mozambique, Nigeria, Rwanda, Senegal, Tanzania, Uganda, Zambia and Zimbabwe. The WHO cone bioassay tests were used to assess the mortality rate of mosquitoes exposed to insecticide-treated mud, wood, cement, and other commonly used housing materials. Baseline tests were performed within weeks of IRS application and follow-up tests were continued until the mortality of exposed mosquitoes dropped below 80% or the program monitoring period ended. Residual efficacy in months was then evaluated with respect to WHO guidelines that provide suggested ranges of residual efficacy for insecticide formulations recommended for use in IRS. Where the data allowed, direct

  18. Adolescent egocentrism and indoor tanning: is the relationship direct or mediated?

    PubMed Central

    Banerjee, Smita C.; Greene, Kathryn; Yanovitzky, Itzhak; Bagdasarov, Zhanna; Choi, Soe Yoon; Magsamen-Conrad, Kate

    2016-01-01

    This paper explored how imaginary audience and personal fable ideations contribute to adolescent indoor tanning intentions directly and indirectly through the way they shape pro-tanning attitude and association with peers who use tanning beds. Five hundred and ninety-five male (n = 207) and female (n = 387) adolescents, ranging in age from 11 to 19 (M = 16.87; SD = 1.34) years completed a cross-sectional survey. Measures included imaginary audience, personal fable (three dimensions: invulnerability, uniqueness, and omnipotence), pro-tanning attitude, association with peers who use tanning beds, and tanning bed use intentions. Bootstrapping analyses documented that imaginary audience ideations are indirectly associated with indoor tanning intentions through the mediation of pro-tanning attitude and association with peers who use tanning beds. Of the personal fable ideations, only invulnerability ideation is indirectly associated with indoor tanning intentions through the mediation of association with peers who use tanning beds. Design and evaluation of interventions and campaigns to reduce indoor tanning must be targeted to adolescents varying in imaginary audience ideations differently. PMID:28042281

  19. Adolescent egocentrism and indoor tanning: is the relationship direct or mediated?

    PubMed

    Banerjee, Smita C; Greene, Kathryn; Yanovitzky, Itzhak; Bagdasarov, Zhanna; Choi, Soe Yoon; Magsamen-Conrad, Kate

    2015-01-01

    This paper explored how imaginary audience and personal fable ideations contribute to adolescent indoor tanning intentions directly and indirectly through the way they shape pro-tanning attitude and association with peers who use tanning beds. Five hundred and ninety-five male ( n = 207) and female ( n = 387) adolescents, ranging in age from 11 to 19 ( M = 16.87; SD = 1.34) years completed a cross-sectional survey. Measures included imaginary audience, personal fable (three dimensions: invulnerability, uniqueness, and omnipotence), pro-tanning attitude, association with peers who use tanning beds, and tanning bed use intentions. Bootstrapping analyses documented that imaginary audience ideations are indirectly associated with indoor tanning intentions through the mediation of pro-tanning attitude and association with peers who use tanning beds. Of the personal fable ideations, only invulnerability ideation is indirectly associated with indoor tanning intentions through the mediation of association with peers who use tanning beds. Design and evaluation of interventions and campaigns to reduce indoor tanning must be targeted to adolescents varying in imaginary audience ideations differently.

  20. Indoor Air Pollution

    MedlinePlus

    ... is known as sick building syndrome. Usually indoor air quality problems only cause discomfort. Most people feel better ... and getting rid of pollutants can improve the quality of your indoor air. Environmental Protection Agency

  1. Dramatic Decrease in Malaria Transmission after Large-Scale Indoor Residual Spraying with Bendiocarb in Benin, an Area of High Resistance of Anopheles gambiae to Pyrethroids

    PubMed Central

    Akogbeto, Martin; Padonou, Gil Germain; Bankole, Honore Sourou; Gazard, Dorothee Kinde; Gbedjissi, Ghelus Louis

    2011-01-01

    In 2008, the National Malaria Control Program in Benin implemented a vector control intervention based on indoor residual spraying (IRS). Four districts of high resistance of Anopheles gambiae to pyrethroids were sprayed with bendiocarb. More than 350,000 inhabitants have been protected. Entomologic parameters in the control area were compared with those in intervention sites. The study has shown a drastic decrease in the An. gambiae biting rate in the sprayed areas. Results of an enzyme-linked immunosorbent assay were negative for Plasmodium falciparum antigen during the entire period of the intervention. No household members received infected bites (entomologic inoculation rate = 0 during January–July). Parous rates were low in areas covered by IRS because bendiocarb is not conducive to long-term mosquito survival. Bendiocarb was found to be a good alternative insecticide for IRS in Benin, in areas where An. gambiae has developed high resistance to pyrethroids. PMID:21976555

  2. Current Indoor Air Quality in Japan.

    PubMed

    Jinno, Hideto

    2016-01-01

    People spend more than two thirds of their daily time indoors. Hence, maintaining a healthy indoor environment is indispensable for the prevention of building related illness. In Japan, guidelines for indoor air quality have been established for 13 volatile/semi-volatile organic compounds (VOCs/SVOCs). These guidelines are now under revision by the Committee on Sick House Syndrome: Indoor Air Pollution. In order to gain information on the current indoor air pollutants and their levels, we carried out a nation-wide survey of VOCs and aldehydes in indoor residential air during 2012-2013. In this review, I concisely summarized the current indoor air quality of Japan.

  3. THE POTENTIAL FOR HUMAN EXPOSURES TO PET-BORNE DIAZINON RESIDUES FOLLOWING RESIDENTIAL LAWN APPLICATIONS

    EPA Science Inventory

    This observational study examined the potential for indoor/outdoor pet dogs to be an important pathway for transporting diazinon residues into homes and onto occupants following residential lawn applications. The primary objective was to investigate the potential exposures of chi...

  4. Quantifying the contribution of ambient and indoor-generated fine particles to indoor air in residential environments.

    PubMed

    MacNeill, M; Kearney, J; Wallace, L; Gibson, M; Héroux, M E; Kuchta, J; Guernsey, J R; Wheeler, A J

    2014-08-01

    Indoor fine particles (FPs) are a combination of ambient particles that have infiltrated indoors, and particles that have been generated indoors from activities such as cooking. The objective of this paper was to estimate the infiltration factor (Finf ) and the ambient/non-ambient components of indoor FPs. To do this, continuous measurements were collected indoors and outdoors for seven consecutive days in 50 non-smoking homes in Halifax, Nova Scotia in both summer and winter using DustTrak (TSI Inc) photometers. Additionally, indoor and outdoor gravimetric measurements were made for each 24-h period in each home, using Harvard impactors (HI). A computerized algorithm was developed to remove (censor) peaks due to indoor sources. The censored indoor/outdoor ratio was then used to estimate daily Finfs and to determine the ambient and non-ambient components of total indoor concentrations. Finf estimates in Halifax (daily summer median = 0.80; daily winter median = 0.55) were higher than have been reported in other parts of Canada. In both winter and summer, the majority of FP was of ambient origin (daily winter median = 59%; daily summer median = 84%). Predictors of the non-ambient component included various cooking variables, combustion sources, relative humidity, and factors influencing ventilation. This work highlights the fact that regional factors can influence the contribution of ambient particles to indoor residential concentrations. Ambient and non-ambient particles have different risk management approaches, composition, and likely toxicity. Therefore, a better understanding of their contribution to the indoor environment is important to manage the health risks associated with fine particles (FPs) effectively. As well, a better understanding of the factors Finf can help improve exposure assessment and contribute to reduced exposure misclassification in epidemiologic studies. © 2013 Her Majesty the Queen in Right of Canada Indoor Air © 2013 John Wiley & Sons

  5. Vapor Transport to Indoor Environments

    EPA Science Inventory

    The indoor environment is an important microenvironment for human exposure to chemicals, both because people spend most of their time indoors and because chemicals are often at higher concentrations indoors versus outdoors. This chapter reviews the major components in estimating ...

  6. Indoor Environment in Residential Prefabricated Buildings

    NASA Astrophysics Data System (ADS)

    Kraus, Michal; Juhásová Šenitková, Ingrid

    2017-10-01

    The contribution presents results of the experimental measurement of indoor air quality in residential prefabricated buildings. People spend about 90% of their life in the indoor environment of buildings. Hygrothermal parameters and indoor air quality are the essential component that define the quality of the indoor environment. The results of case study characterize the quality of the indoor environment of the ordinary occupants in housing unit of residential prefabricated building. A current problem of revitalized prefabricated buildings is inadequate air exchange and related thereto to poor indoor air quality. The experimental measurements were carried out just before and at the beginning of the heating season (from 1st October to 30th November 2016). Heating season was launched in the middle of experimental measurement. The wireless indoor sensor Elgato Eve Room was used for measurements. The obtained values of indoor air temperature [°C], relative humidity [%] and indoor air quality [ppm] are describe and analysis in this study. The results of the study indicate that the values of temperature and indoor air quality meet optimal levels during the experiment with nuances. The mean air temperature in the indoor environment is 22.43 °C. The temperature of the indoor environment is held at the optimum level (18-24 °C) for 94.50% time of the experimental measurements. In addition, the indoor air quality in the context of the content of harmful volatile organic compounds (VOCs) has been excellent for almost 91% time of the total experiment. However, the values of relative humidity were less than the optimum value nearly 40% of the total observed time. The mean 10-minutes values of relative humidity during the heating season is about 10% lower than the mean 10-minutes relative humidity before the heating season.

  7. Increased Levels of Markers of Microbial Exposure in Homes with Indoor Storage of Organic Household Waste

    PubMed Central

    Wouters, Inge M.; Douwes, Jeroen; Doekes, Gert; Thorne, Peter S.; Brunekreef, Bert; Heederik, Dick J. J.

    2000-01-01

    As part of environmental management policies in Europe, separate collection of organic household waste and nonorganic household waste has become increasingly common. As waste is often stored indoors, this policy might increase microbial exposure in the home environment. In this study we evaluated the association between indoor storage of organic waste and levels of microbial agents in house dust. The levels of bacterial endotoxins, mold β(1→3)-glucans, and fungal extracullar polysaccharides (EPS) of Aspergillus and Penicillium species were determined in house dust extracts as markers of microbial exposure. House dust samples were collected in 99 homes in The Netherlands selected on the basis of whether separated organic waste was present in the house. In homes in which separated organic waste was stored indoors for 1 week or more the levels of endotoxin, EPS, and glucan were 3.2-, 7.6-, and 4.6-fold higher, respectively (all P < 0.05), on both living room and kitchen floors than the levels in homes in which only nonorganic residual waste was stored indoors. Increased levels of endotoxin and EPS were observed, 2.6- and 2.1-fold (P < 0.1), respectively, when separated organic waste was stored indoors for 1 week or less, whereas storage of nonseparated waste indoors had no effect on microbial agent levels (P > 0.2). The presence of textile floor covering was another major determinant of microbial levels (P < 0.05). Our results indicate that increased microbial contaminant levels in homes are associated with indoor storage of separated organic waste. These increased levels might increase the risk of bioaerosol-related respiratory symptoms in susceptible people. PMID:10653727

  8. Effectiveness and Cost of Insecticide-Treated Bed Nets and Indoor Residual Spraying for the Control of Cutaneous Leishmaniasis: A Cluster-Randomized Control Trial in Morocco

    PubMed Central

    Faraj, Chafika; Yukich, Joshua; Adlaoui, El Bachir; Wahabi, Rachid; Mnzava, Abraham Peter; Kaddaf, Mustapha; El Idrissi, Abderrahmane Laamrani; Ameur, Btissam; Kleinschmidt, Immo

    2016-01-01

    Cutaneous leishmaniasis (CL) remains an important public health problem in Morocco. A cluster-randomized trial was conducted with the following three study arms: 1) long-lasting insecticide-treated nets (LLINs) plus standard of care environmental management (SoC-EM), 2) indoor residual spraying (IRS) with α-cypermethrin plus SoC-EM, and 3) SoC-EM alone. Incidence of new CL cases by passive and active case detection, sandfly abundance, and cost and cost-effectiveness was compared between study arms over 5 years. Incidence of CL and sandfly abundance were significantly lower in the IRS arm compared with SoC-EM (CL incidence rate ratio = 0.32, 95% confidence interval [CI] = 0.15–0.69, P = 0.005 and sandfly abundance ratio = 0.39, 95% CI = 0.18–0.85, P = 0.022). Reductions in the LLIN arm of the study were not significant, possibly due to poor compliance. IRS was effective and more cost-effective for the prevention of CL in Morocco. PMID:26811431

  9. Polluted air--outdoors and indoors.

    PubMed

    Myers, I; Maynard, R L

    2005-09-01

    Many air pollutants which are considered important in ambient (outdoor) air are also found, sometimes at higher levels, in indoor air. With demanding standards having been set for many of these pollutants, both in the workplace and ambient air, consideration of the problems posed by indoor pollution is gaining pace. Studies on exposure to pollutants found in the indoor domestic environment are increasing and are contributing to an already significant compilation of datasets. Improvement in monitoring techniques has helped this process. Documented reports of fatalities from carbon monoxide poisonings are still worrying. However, studies on health effects of non-fatal, long term, low dose, indoor exposure to carbon monoxide and other pollutants, are still inconclusive and too infrequently documented. Of particular concern are the levels of air pollutants found in the domestic indoor environment in developing countries, despite simple interventions such as vented stoves having shown their value. Exposure to biomass smoke is still a level that would be considered unacceptable on health grounds in developed countries. As in the occupational environment, steps need to be taken to control the risks from exposure to the harmful constituents of indoor air in the home. However, the difficulty regarding regulation of the domestic indoor environment is its inherent privacy. Monitoring levels of pollutants in the home and ensuring regulations are adhered to, would likely prove difficult, especially when individual behaviour patterns and activities have the greatest influence on pollutant levels in indoor air. To this end, the Department of Health is developing guidance on indoor air pollution to encourage the reduction of pollutant levels in indoor domestic air. The importance of the effects of domestic indoor air on health and its contribution to the health of the worker are increasingly appreciated. Occupational physicians, by training and interest, are well placed to extend

  10. Analytical procedure for the determination of very volatile organic compounds (C3-C6) in indoor air.

    PubMed

    Schieweck, Alexandra; Gunschera, Jan; Varol, Deniz; Salthammer, Tunga

    2018-05-01

    The substance group of very volatile organic compounds (VVOCs) is moving into the focus of indoor air analysis, facing ongoing regulations at international and European levels targeting on indoor air quality and human health. However, there exists at present no validated analysis for the identification and quantification of VVOCs in indoor air. Therefore, the present study targeted on the development of an analytical method in order to sample the maximum possible quantity of VVOCs in indoor air on solid sorbents with subsequent analysis by thermal desorption and coupled gas chromatography/mass spectrometry (TDS-GC/MS). For this purpose, it was necessary to investigate the performance of available sorbents and to optimize the parameters of GC/MS analysis. Stainless steel tubes filled with Carbograph 5TD were applied successfully for low-volume sampling (2-4 l) with minimal breakthrough (< 1%). With the developed method, VVOCs between C 3 and C 6 of different volatility and polarity  can be detected even in trace quantities with low limits of quantitation (LOQ; 1-3 μg m -3 ). Limitations occur for low molecular weight compounds ≤C 3 , especially for polar substances, such as carboxylic acids and for some aldehydes and alcohols. Consequently, established methods for the quantification of these compounds in indoor air cannot be fully substituted yet. At least three different analytical techniques are needed to cover the large spectrum of relevant VVOCs in indoor air. In addition, unexpected reaction products might occur and need to be taken into account to avoid misinterpretation of chromatographic signals. Graphical abstract Solid sorbent sampling of VVOCs (C 3 -C 6 ) in indoor air with subsequent TDS-GC/MS analysis.

  11. Indoor navigation by image recognition

    NASA Astrophysics Data System (ADS)

    Choi, Io Teng; Leong, Chi Chong; Hong, Ka Wo; Pun, Chi-Man

    2017-07-01

    With the progress of smartphones hardware, it is simple on smartphone using image recognition technique such as face detection. In addition, indoor navigation system development is much slower than outdoor navigation system. Hence, this research proves a usage of image recognition technique for navigation in indoor environment. In this paper, we introduced an indoor navigation application that uses the indoor environment features to locate user's location and a route calculating algorithm to generate an appropriate path for user. The application is implemented on Android smartphone rather than iPhone. Yet, the application design can also be applied on iOS because the design is implemented without using special features only for Android. We found that digital navigation system provides better and clearer location information than paper map. Also, the indoor environment is ideal for Image recognition processing. Hence, the results motivate us to design an indoor navigation system using image recognition.

  12. Cost-effectiveness of adding indoor residual spraying to case management in Afghan refugee settlements in Northwest Pakistan during a prolonged malaria epidemic.

    PubMed

    Howard, Natasha; Guinness, Lorna; Rowland, Mark; Durrani, Naeem; Hansen, Kristian S

    2017-10-01

    Financing of malaria control for displaced populations is limited in scope and duration, making cost-effectiveness analyses relevant but difficult. This study analyses cost-effectiveness of adding prevention through targeted indoor residual spraying (IRS) to case management in Afghan refugee settlements in Pakistan during a prolonged malaria epidemic. An intervention study design was selected, taking a societal perspective. Provider and household costs of vector control and case management were collected from provider records and community survey. Health outcomes (e.g. cases and DALYs averted) were derived and incremental cost-effectiveness ratios (ICERs) for cases prevented and DALYs averted calculated. Population, treatment cost, women's time, days of productivity lost, case fatality rate, cases prevented, and DALY assumptions were tested in sensitivity analysis. Malaria incidence peaked at 44/1,000 population in year 2, declining to 14/1,000 in year 5. In total, 370,000 malaria cases, 80% vivax, were diagnosed and treated and an estimated 67,988 vivax cases and 18,578 falciparum and mixed cases prevented. Mean annual programme cost per capita was US$0.56. The additional cost of including IRS over five years per case prevented was US$39; US$50 for vivax (US$43 in years 1-3, US$80 in years 4-5) and US$182 for falciparum (US$139 in years 1-3 and US$680 in years 4-5). Per DALY averted this was US$266 (US$220 in years 1-3 and US$486 in years 4-5) and thus 'highly cost-effective' or cost-effective using WHO and comparison thresholds. Adding IRS was cost-effective in this moderate endemicity, low mortality setting. It was more cost-effective when transmission was highest, becoming less so as transmission reduced. Because vivax was three times more common than falciparum and the case fatality rate was low, cost-effectiveness estimations for cases prevented appear reliable and more definitive for vivax malaria.

  13. Cost-effectiveness of adding indoor residual spraying to case management in Afghan refugee settlements in Northwest Pakistan during a prolonged malaria epidemic

    PubMed Central

    Guinness, Lorna; Rowland, Mark; Durrani, Naeem; Hansen, Kristian S.

    2017-01-01

    Introduction Financing of malaria control for displaced populations is limited in scope and duration, making cost-effectiveness analyses relevant but difficult. This study analyses cost-effectiveness of adding prevention through targeted indoor residual spraying (IRS) to case management in Afghan refugee settlements in Pakistan during a prolonged malaria epidemic. Methods/Findings An intervention study design was selected, taking a societal perspective. Provider and household costs of vector control and case management were collected from provider records and community survey. Health outcomes (e.g. cases and DALYs averted) were derived and incremental cost-effectiveness ratios (ICERs) for cases prevented and DALYs averted calculated. Population, treatment cost, women’s time, days of productivity lost, case fatality rate, cases prevented, and DALY assumptions were tested in sensitivity analysis. Malaria incidence peaked at 44/1,000 population in year 2, declining to 14/1,000 in year 5. In total, 370,000 malaria cases, 80% vivax, were diagnosed and treated and an estimated 67,988 vivax cases and 18,578 falciparum and mixed cases prevented. Mean annual programme cost per capita was US$0.56. The additional cost of including IRS over five years per case prevented was US$39; US$50 for vivax (US$43 in years 1–3, US$80 in years 4–5) and US$182 for falciparum (US$139 in years 1–3 and US$680 in years 4–5). Per DALY averted this was US$266 (US$220 in years 1–3 and US$486 in years 4–5) and thus ‘highly cost-effective’ or cost-effective using WHO and comparison thresholds. Conclusions Adding IRS was cost-effective in this moderate endemicity, low mortality setting. It was more cost-effective when transmission was highest, becoming less so as transmission reduced. Because vivax was three times more common than falciparum and the case fatality rate was low, cost-effectiveness estimations for cases prevented appear reliable and more definitive for vivax malaria

  14. Lifetime history of indoor tanning in young people: a retrospective assessment of initiation, persistence, and correlates

    PubMed Central

    2012-01-01

    Background Despite educational and public health campaigns to convey the risks of indoor tanning, many individuals around the world continue to engage in this behavior. Few descriptive studies of indoor tanning have collected information pertaining to the lifetime history of indoor tanning, thereby limiting our ability to understand indoor tanning patterns and potentially target interventions for individuals who not only initiate, but continue to persistently engage in indoor tanning. Methods In-person interviews elicited detailed retrospective information on lifetime history of indoor tanning among white individuals (n = 401) under age 40 seen by a dermatologist for a minor benign skin condition. These individuals were controls in a case-control study of early-onset basal cell carcinoma. Outcomes of interest included ever indoor tanning in both males and females, as well as persistent indoor tanning in females - defined as females over age 31 who tanned indoors at least once in the last three or all four of four specified age periods (ages 11-15, 16-20, 21-30 and 31 or older). Multivariate logistic regression was used to identify sociodemographic and lifestyle correlates of ever and persistent indoor tanning in females. Results Approximately three-quarters (73.3%) of females and 38.3% of males ever tanned indoors, with a median age of initiation of 17.0 and 21.5, respectively. Among indoor tanners, 39.3% of females and 21.7% of males reported being burned while indoor tanning. Female ever indoor tanners were younger, had darker color eyes, and sunbathed more frequently than females who never tanned indoors. Using unique lifetime exposure data, 24.7% of female indoor tanners 31 and older persistently tanned indoors starting as teenagers. Female persistent indoor tanners drank significantly more alcohol, were less educated, had skin that tanned with prolonged sun exposure, and sunbathed outdoors more frequently than non-persistent tanners. Conclusions Indoor tanning

  15. 9 CFR 3.51 - Facilities, indoor.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Facilities, indoor. 3.51 Section 3.51... Facilities and Operating Standards § 3.51 Facilities, indoor. (a) Heating. Indoor housing facilities for rabbits need not be heated. (b) Ventilation. Indoor housing facilities for rabbits shall be adequately...

  16. State Indoor Tanning Laws and Prevalence of Indoor Tanning Among US High School Students, 2009-2015.

    PubMed

    Qin, Jin; Holman, Dawn M; Jones, Sherry Everett; Berkowitz, Zahava; Guy, Gery P

    2018-07-01

    To examine the association between state indoor tanning laws and indoor tanning behavior using nationally representative samples of US high school students younger than 18 years. We combined data from the 2009, 2011, 2013, and 2015 national Youth Risk Behavior Surveys (n = 41 313) to analyze the association between 2 types of state indoor tanning laws (age restriction and parental permission) and the prevalence of indoor tanning during the 12 months before the survey, adjusting for age, race/ethnicity, and survey year, and stratified by gender. Age restriction laws were associated with a 47% (P < .001) lower indoor tanning prevalence among female high school students. Parental permission laws were not found to be associated with indoor tanning prevalence among either female or male high school students. Age restriction laws could contribute to less indoor tanning, particularly among female high school students. Such reductions may reduce the health and economic burden of skin cancer.

  17. Variation of indoor radon concentration and ambient dose equivalent rate in different outdoor and indoor environments.

    PubMed

    Stojanovska, Zdenka; Boev, Blazo; Zunic, Zora S; Ivanova, Kremena; Ristova, Mimoza; Tsenova, Martina; Ajka, Sorsa; Janevik, Emilija; Taleski, Vaso; Bossew, Peter

    2016-05-01

    Subject of this study is an investigation of the variations of indoor radon concentration and ambient dose equivalent rate in outdoor and indoor environments of 40 dwellings, 31 elementary schools and five kindergartens. The buildings are located in three municipalities of two, geologically different, areas of the Republic of Macedonia. Indoor radon concentrations were measured by nuclear track detectors, deployed in the most occupied room of the building, between June 2013 and May 2014. During the deploying campaign, indoor and outdoor ambient dose equivalent rates were measured simultaneously at the same location. It appeared that the measured values varied from 22 to 990 Bq/m(3) for indoor radon concentrations, from 50 to 195 nSv/h for outdoor ambient dose equivalent rates, and from 38 to 184 nSv/h for indoor ambient dose equivalent rates. The geometric mean value of indoor to outdoor ambient dose equivalent rates was found to be 0.88, i.e. the outdoor ambient dose equivalent rates were on average higher than the indoor ambient dose equivalent rates. All measured can reasonably well be described by log-normal distributions. A detailed statistical analysis of factors which influence the measured quantities is reported.

  18. Impact of changing over of insecticide from synthetic pyrethroids to DDT for indoor residual spray in a malaria endemic area of Orissa, India

    PubMed Central

    Sharma, Surya K.; Upadhyay, Ashok K.; Haque, Mohammed A.; Tyagi, Prajesh K.; Kindo, Bikrant K.

    2012-01-01

    Background & objectives: Development of insecticide resistance in malaria vectors has been a major problem for achieving effective vector control. Due to limited availability of insecticides, the only option is management of resistance by judiciously using the insecticides and rotating them to maintain their effectiveness. This study was carried out in a malaria endemic area of Sundergarh district in Orissa where synthetic pyrethroids (SP) were in use for the last couple of years. The change-over from SP to DDT was done in one arm of study, and the other two arms remained on SP and insecticide-treated nets (ITN). Entomological and parasitological monitoring was done to assess the impact. Methods: The study design comprised of three arms (i) two rounds of indoor residual spraying (IRS) with DDT 1g/m2 as a change-over insecticide in areas previously under synthetic pyrethroids; (ii) two rounds of IRS with synthetic pyrethroid (alphacypermethrin, ACM) @ 25 mg/m2; and (iii) an unsprayed area under ITN/long lasting insecticide nets (LNs). Indoor residual spraying was undertaken under strict supervision to maintain quality and coverage. Contact bioassays were conducted to know the persistence of insecticide on sprayed surfaces and adult vector density was monitored in fixed and randomly selected houses. Malaria incidence was measured through fortnightly domiciliary surveillance under primary health care system in all the study villages. Results: The insecticide susceptibility tests showed that An.culicifacies was resistant to DDT but susceptible to malathion and ACM. However, An. fluviatilis was susceptible to all the three insecticides. ACM was effective in killing An. culicifacies on mud and wooden sprayed surfaces and maintained effective bioefficacy ranging from 92 to 100 per cent up to five months, whereas DDT failed to achieve effective mortality in An.culicifacies. However, there was significant decline in the density of An.culicifacies in ACM and DDT areas in

  19. [Impact of air fresheners and deodorizers on the indoor total volatile organic compounds].

    PubMed

    Jinno, Hideto; Tanaka-Kagawa, Toshiko; Obama, Tomoko; Miyagawa, Makoto; Yoshikawa, Jun; Komatsu, Kazuhiro; Tokunaga, Hiroshi

    2007-01-01

    Indoor air quality is a growing health concern because of the increased incidence of the building-related illness, such as sick-building syndrome and multiple chemical sensitivity/idiopathic environmental intolerance. In order to effectively reduce the unnecessary chemical exposure in the indoor environment, it would be important to quantitatively compare the emissions from many types of sources. Besides the chemical emissions from the building materials, daily use of household products may contribute at significant levels to the indoor volatile organic compounds (VOCs). In this study, we investigated the emission rate of VOCs and carbonyl compounds for 30 air fresheners and deodorizers by the standard small chamber test method (JIS A 1901). The total VOC (TVOC) emission rates of these household products ranged from the undetectable level (< 20 microg/unit/h) to 6,900 microg/unit/h. The mean TVOC emission rate of the air fresheners for indoor use (16 products) was 1,400 microg/unit/ h and that of the deodorizers for indoor use (6 products) was 58 microg/unit/h, indicating that the fragrances in the products account for the major part of the TVOC emissions. Based on the emission rates, the impacts on the indoor TVOC were estimated by the simple model with a volume of 17.4 m3 and a ventilation frequency of 0.5 times/h. The mean of the TVOC increment for the indoor air fresheners was 170 microg/m3, accounting for 40% of the current provisional target value, 400 microg/m3. These results suggest that daily use of household products can significantly influence the indoor air quality.

  20. Robust 3D Position Estimation in Wide and Unconstrained Indoor Environments

    PubMed Central

    Mossel, Annette

    2015-01-01

    In this paper, a system for 3D position estimation in wide, unconstrained indoor environments is presented that employs infrared optical outside-in tracking of rigid-body targets with a stereo camera rig. To overcome limitations of state-of-the-art optical tracking systems, a pipeline for robust target identification and 3D point reconstruction has been investigated that enables camera calibration and tracking in environments with poor illumination, static and moving ambient light sources, occlusions and harsh conditions, such as fog. For evaluation, the system has been successfully applied in three different wide and unconstrained indoor environments, (1) user tracking for virtual and augmented reality applications, (2) handheld target tracking for tunneling and (3) machine guidance for mining. The results of each use case are discussed to embed the presented approach into a larger technological and application context. The experimental results demonstrate the system’s capabilities to track targets up to 100 m. Comparing the proposed approach to prior art in optical tracking in terms of range coverage and accuracy, it significantly extends the available tracking range, while only requiring two cameras and providing a relative 3D point accuracy with sub-centimeter deviation up to 30 m and low-centimeter deviation up to 100 m. PMID:26694388

  1. Indoorgml - a Standard for Indoor Spatial Modeling

    NASA Astrophysics Data System (ADS)

    Li, Ki-Joune

    2016-06-01

    With recent progress of mobile devices and indoor positioning technologies, it becomes possible to provide location-based services in indoor space as well as outdoor space. It is in a seamless way between indoor and outdoor spaces or in an independent way only for indoor space. However, we cannot simply apply spatial models developed for outdoor space to indoor space due to their differences. For example, coordinate reference systems are employed to indicate a specific position in outdoor space, while the location in indoor space is rather specified by cell number such as room number. Unlike outdoor space, the distance between two points in indoor space is not determined by the length of the straight line but the constraints given by indoor components such as walls, stairs, and doors. For this reason, we need to establish a new framework for indoor space from fundamental theoretical basis, indoor spatial data models, and information systems to store, manage, and analyse indoor spatial data. In order to provide this framework, an international standard, called IndoorGML has been developed and published by OGC (Open Geospatial Consortium). This standard is based on a cellular notion of space, which considers an indoor space as a set of non-overlapping cells. It consists of two types of modules; core module and extension module. While core module consists of four basic conceptual and implementation modeling components (geometric model for cell, topology between cells, semantic model of cell, and multi-layered space model), extension modules may be defined on the top of the core module to support an application area. As the first version of the standard, we provide an extension for indoor navigation.

  2. Physiologic responses during indoor cycling.

    PubMed

    Battista, Rebecca A; Foster, Carl; Andrew, Jessica; Wright, Glenn; Lucia, Alejandro; Porcari, John P

    2008-07-01

    During the last decade, there has been active interest in indoor cycling (e.g., spinning) as a method of choreographed group exercise. Recent studies have suggested that exercise intensity during indoor cycling may be quite high and may transiently exceed Vo2max. This study sought to confirm these findings, as the apparent high intensity of indoor cycling has implications for both the efficacy and the risk of indoor cycling as an exercise method. Twenty healthy female students performed an incremental exercise test to define Vo2max and performed 2 videotaped indoor exercise classes lasting 45 minutes and 35 minutes. Vo2, heart rate (HR), and rating of perceived exertion (RPE) were measured during the indoor cycling classes, with Vo2 data integrated in 30-second intervals. The mean %Vo2max during the indoor cycling classes was modest (74 +/- 14% Vo2max and 66 +/- 14%Vo2max, respectively). However, 52% and 35% of the time during the 45- and 35-minute classes was spent at intensities greater than the ventilatory threshold (VT). The HR response indicated that 35% and 38% of the session time was above the HR associated with VT. In 10 of the 40 exercise sessions, there were segments in which the momentary Vo2 exceeded Vo2max observed during incremental testing, and the cumulative time with exercise intensity greater than Vo2max ranged from 0.5 to 14.0 minutes. It can be concluded that although the intensity of indoor cycling in healthy, physically active women is moderate, there are frequent observations of transient values of Vo2 exceeding Vo2max, and a substantial portion of the exercise bouts at intensities greater than VT. As such, the data suggest that indoor cycling must be considered a high-intensity exercise mode of exercise training, which has implications for both efficacy and risk.

  3. Source apportionment of indoor air pollution

    NASA Astrophysics Data System (ADS)

    Sexton, Ken; Hayward, Steven B.

    An understanding of the relative contributions from important pollutant sources to human exposures is necessary for the design and implementation of effective control strategies. In the past, societal efforts to control air pollution have focused almost exclusively on the outdoor (ambient) environment. As a result, substantial amounts of time and money have been spent to limit airborne discharges from mobile and stationary sources. Yet it is now recognized that exposures to elevated pollutant concentrations often occur as a result of indoor, rather than outdoor, emissions. While the major indoor sources have been identified, their relative impacts on indoor air quality have not been well defined. Application of existing source apportionment models to nonindustrial indoor environments is only just beginning. It is possible that these models might be used to distinguish between indoor and outdoor emissions, as well as to distinguish among indoor sources themselves. However, before the feasibility and suitability of source-apportionment methods for indoor applications can be assessed adequately, it is necessary to take account of model assumptions and associated data requirements. This paper examines the issue of indoor source apportionment and reviews the need for emission characterization studies to support such source-apportionment efforts.

  4. Controlling Indoor Air Pollution.

    ERIC Educational Resources Information Center

    Nero, Anthony V, Jr.

    1988-01-01

    Discusses the health risks posed by indoor air pollutants, such as airborne combustion products, toxic chemicals, and radioactivity. Questions as to how indoor air might be regulated. Calls for new approaches to environmental protection. (TW)

  5. Organic compounds in indoor air—their relevance for perceived indoor air quality?

    NASA Astrophysics Data System (ADS)

    Wolkoff, Peder; Nielsen, Gunnar D.

    It is generally believed that indoor air pollution, one way or another may cause indoor air complaints. However, any association between volatile organic compounds (VOCs) concentrations and increase of indoor climate complaints, like the sick-building syndrome symptoms, is not straightforward. The reported symptom rates of, in particular, eye and upper airway irritation cannot generally be explained by our present knowledge of common chemically non-reactive VOCs measured indoors. Recently, experimental evidence has shown those chemical reactions between ozone (either with or without nitrogen dioxide) and unsaturated organic compounds (e.g. from citrus and pine oils) produce strong eye and airway irritating species. These have not yet been well characterised by conventional sampling and analytical techniques. The chemical reactions can occur indoors, and there is indirect evidence that they are associated with eye and airway irritation. However, many other volatile and non-volatile organic compounds have not generally been measured which could equally well have potent biological effects and cause an increase of complaint rates, and posses a health/comfort risk. As a consequence, it is recommended to use a broader analytical window of organic compounds than the classic VOC window as defined by the World Health Organisation. It may include hitherto not yet sampled or identified intermediary species (e.g., radicals, hydroperoxides and ionic compounds like detergents) as well as species deposited onto particles. Additionally, sampling strategies including emission testing of building products should carefully be linked to the measurement of organic compounds that are expected, based on the best available toxicological knowledge, to have biological effects at indoor concentrations.

  6. Indoor Tanning Dependence in Young Adult Women.

    PubMed

    Mays, Darren; Atkins, Michael B; Ahn, Jaeil; Tercyak, Kenneth P

    2017-11-01

    Background: There is mounting evidence that young people can develop a dependence on indoor tanning, but research on factors associated with indoor tanning dependence remains limited. Methods: This cross-sectional study investigated factors associated with indoor tanning dependence in a community sample of 389 non-Hispanic white young adult women ages 18 to 30 who had indoor tanned ≥1 time in the past year. Participants completed measures of indoor tanning dependence, including the modified CAGE and modified Diagnostic and Statistical Manual for Mental Disorders-IV psychiatric screening assessments, indoor tanning behavior and beliefs, and behavioral and psychiatric comorbidity. Results: Overall, 22.6% of the sample screened positive for indoor tanning dependence. In multivariable analyses, indoor tanning dependence was associated with younger age of indoor tanning initiation [adjusted odds ratio (aOR) = 0.79; P = 0.017], indoor tanning ≥20 times in the past year (aOR = 3.03; P = 0.015), stronger beliefs about the benefits of tanning (aOR = 2.15; P = 0.004), greater perceived susceptibility to indoor tanning risks (aOR = 2.72; P < 0.001), stronger beliefs about physical appearance (aOR = 1.73; P = 0.037), and depressive symptoms (aOR = 3.79; P < 0.001). Conclusions: Indoor tanning dependence among young, non-Hispanic white women is associated with behaviors that increase the risk of skin cancer, beliefs favoring the perceived benefits of tanning, and comorbid risks such as stronger beliefs about physical appearance and depressed mood. Impact: Comprehensive skin cancer prevention efforts should address indoor tanning dependence among young women and its leading risk factors. Cancer Epidemiol Biomarkers Prev; 26(11); 1636-43. ©2017 AACR . ©2017 American Association for Cancer Research.

  7. Strategies to Reduce Indoor Tanning

    PubMed Central

    Holman, Dawn M.; Fox, Kathleen A.; Glenn, Jeffrey D.; Guy, Gery P.; Watson, Meg; Baker, Katie; Cokkinides, Vilma; Gottlieb, Mark; Lazovich, DeAnn; Perna, Frank M.; Sampson, Blake P.; Seidenberg, Andrew B.; Sinclair, Craig; Geller, Alan C.

    2015-01-01

    Exposure to ultraviolet radiation from indoor tanning device use is associated with an increased risk of skin cancer, including risk of malignant melanoma, and is an urgent public health problem. By reducing indoor tanning, future cases of skin cancer could be prevented, along with the associated morbidity, mortality, and healthcare costs. On August 20, 2012, the CDC hosted a meeting to discuss the current body of evidence on strategies to reduce indoor tanning as well as research gaps. Using the Action Model to Achieve Healthy People 2020 Overarching Goals as a framework, the current paper provides highlights on the topics that were discussed, including (1) the state of the evidence on strategies to reduce indoor tanning; (2) the tools necessary to effectively assess, monitor, and evaluate the short- and long-term impact of interventions designed to reduce indoor tanning; and (3) strategies to align efforts at the national, state, and local levels through transdisciplinary collaboration and coordination across multiple sectors. Although many challenges and barriers exist, a coordinated, multilevel, transdisciplinary approach has the potential to reduce indoor tanning and prevent future cases of skin cancer. PMID:23683986

  8. Establishing and performing targeted multi-residue analysis for lipid mediators and fatty acids in small clinical plasma samples.

    USDA-ARS?s Scientific Manuscript database

    LC-MS/MS and GC-MS based targeted metabolomics is typically conducted by analyzing and quantifying a cascade of metabolites with methods specifically developed for the metabolite class. Here we describe an approach for the development of multi-residue analytical profiles, calibration standards, and ...

  9. Methotrexate-loaded PLGA nanobubbles for ultrasound imaging and Synergistic Targeted therapy of residual tumor during HIFU ablation.

    PubMed

    Zhang, Xuemei; Zheng, Yuanyi; Wang, Zhigang; Huang, Shuai; Chen, Yu; Jiang, Wei; Zhang, Hua; Ding, Mingxia; Li, Qingshu; Xiao, Xiaoqiu; Luo, Xin; Wang, Zhibiao; Qi, Hongbo

    2014-06-01

    High intensity focused ultrasound (HIFU) has attracted the great attention in tumor ablation due to its non-invasive, efficient and economic features. However, HIFU ablation has its intrinsic limitations for removing the residual tumor cells, thus the tumor recurrence and metastasis cannot be avoided in this case. Herein, we developed a multifunctional targeted poly(lactic-co-glycolic acid) (PLGA) nanobubbles (NBs), which not only function as an efficient ultrasound contrast agent for tumor imaging, but also a targeted anticancer drug carrier and excellent synergistic agent for enhancing the therapeutic efficiency of HIFU ablation. Methotrexate (MTX)-loaded NBs were synthesized and filled with perfluorocarbon gas subsequently using a facile but general double emulsion evaporation method. The active tumor-targeting monoclonal anti-HLA-G antibodies (mAbHLA-G) were further conjugated onto the surface of nanobubbles. The mAbHLA-G/MTX/PLGA NBs could enhance the ultrasound imaging both in vitro and in vivo, and the targeting efficiency to HLA-G overexpressing JEG-3 cells has been demonstrated. The elaborately designed mAbHLA-G/MTX/PLGA NBs can specifically target to the tumor cells both in vitro and in vivo, and their blood circulation time in vivo was much longer than non-targeted MTX/PLGA NBs. Further therapeutic evaluations showed that the targeted NBs as a synergistic agent can significantly improve the efficiency of HIFU ablation by changing the acoustic environment, and the focused ultrasound can promote the on-demand MTX release both in vitro and in vivo. The in vivo histopathology test and immunohistochemical analysis showed that the mAbHLA-G/MTX/PLGA NBs plus HIFU group presented most serious coagulative necrosis, the lowest proliferation index and the highest apoptotic index. Therefore, the successful introduction of targeted mAbHLA-G/MTX/PLGA NBs provides an excellent platform for the highly efficient, imaging-guided and non-invasive HIFU synergistic therapy

  10. The role of aspartic acid residues 405 and 416 of the kidney isotype of sodium-bicarbonate cotransporter 1 in its targeting to the plasma membrane

    PubMed Central

    Kucher, Volodymyr; Li, Emily Y.; Conforti, Laura; Zahedi, Kamyar A.

    2012-01-01

    The NH2 terminus of the sodium-bicarbonate cotransporter 1 (NBCe1) plays an important role in its targeting to the plasma membrane. To identify the amino acid residues that contribute to the targeting of NBCe1 to the plasma membrane, polarized MDCK cells were transfected with expression constructs coding for green fluorescent protein (GFP)-tagged NBCe1 NH2-terminal deletion mutants, and the localization of GFP-tagged proteins was analyzed by confocal microscopy. Our results indicate that the amino acids between residues 399 and 424 of NBCe1A contain important sequences that contribute to its localization to the plasma membrane. Site-directed mutagenesis studies showed that GFP-NBCe1A mutants D405A and D416A are retained in the cytoplasm of the polarized MDCK epithelial cells. Examination of functional activities of D405A and D416A reveals that their activities are reduced compared with the wild-type NBCe1A. Similarly, aspartic acid residues 449 and 460 of pancreatic NBCe1 (NBCe1B), which correspond to residues 405 and 416 of NBCe1A, are also required for its full functional activity and accurate targeting to the plasma membrane. In addition, while replacement of D416 with glutamic acid did not affect the targeting or functional activity of NBCe1A, substitution of D405 with glutamic acid led to the retention of the mutated protein in the intracellular compartment and impaired functional activity. These studies demonstrate that aspartic acid residues 405 and 416 in the NH2 terminus of NBCe1A are important in its accurate targeting to the plasma membrane. PMID:22442137

  11. A multi-residue method for characterization of endocrine disruptors in gaseous and particulate phases of ambient air

    NASA Astrophysics Data System (ADS)

    Alliot, Fabrice; Moreau-Guigon, Elodie; Bourges, Catherine; Desportes, Annie; Teil, Marie-Jeanne; Blanchard, Martine; Chevreuil, Marc

    2014-08-01

    A number of semi-volatile compounds occur in indoor air most of them being considered as potent endocrine disruptors and thus, exerting a possible impact upon health. To assess their concentration levels in indoor air, we developed and validated a method for sampling and multi-residue analysis of 58 compounds including phthalates, polycyclic aromatic hydrocarbons (PAHs), polybromodiphenylethers (PBDEs), polychlorobiphenyls (PCBs), parabens, bisphenol A (BPA) and tetrabromobisphenol A (TBBPA) in gaseous and particulate phases of air. We validated each step of procedures from extraction until analysis. Matrice spiking were performed at extraction, fractionation and purification stages. The more volatile compounds were analyzed with a gas chromatography system coupled with a mass spectrometer (GC/MS) or with a tandem mass spectrometer (GC/MS/MS). The less volatile compounds were analyzed with a liquid chromatography system coupled with a tandem mass spectrometer (LC/MS/MS). Labeled internal standard method was used ensuring high quantification accuracy. The instrumental detection limits were under 1 pg for all compounds and therefore, a limit of quantification averaging 1 pg m-3 for the gaseous and the particulate phases and a volume of 150 m3, except for phthalates, phenol compounds and BDE-209. Satisfactory recoveries were found except for phenol compounds. That method was successfully applied to several indoor air samples (office, apartment and day nursery) and most of the targeted compounds were quantified, mainly occurring in the gaseous phase. The most abundant were phthalates (up to 918 ng m-3 in total air), followed by PCBs > parabens > BPA > PAHs > PBDEs.

  12. Controlling Indoor Air Pollution from Moxibustion

    PubMed Central

    Lu, Chung-Yen; Kang, Sy-Yuan; Liu, Shu-Hui; Mai, Cheng-Wei; Tseng, Chao-Heng

    2016-01-01

    Indoor air quality (IAQ) control of hospitals plays a critical role in protecting both hospital staffs and patients, particularly those who are highly susceptible to the adverse effects of indoor noxious hazards. However, moxibustion in outpatient departments (OPDs) of traditional Chinese medicine (TCM) may be a source of indoor air pollution in hospitals. Some studies have investigated indoor air pollution during moxibustion in Chinese medicine clinics (CMCs) and moxibustion rooms, demonstrating elevated air pollutants that pose a threat to the health of medical staff and patients. Our study investigated the indoor air pollutants of indoor carbon dioxide (CO2), carbon monoxide (CO), formaldehyde (HCHO), total volatile organic compounds (TVOCs), airborne particulate matter with a diameter of ≤10 µm (PM10) and ≤2.5 µm (PM2.5) during moxibustion in an acupuncture and moxibustion room of the OPD in a hospital in Taipei. To evaluate the different control strategies for indoor air pollution from moxibution, a comparison of air pollutants during moxibution among the methods of using alternative old moxa wools, local exhaust ventilation and an air cleaner was conducted. In this study, burning alternative old moxa wools for moxibustion obviously reduced all gaseous pollutants except for aerosols comparing burning fresh moxa wools. Using local exhaust ventilation reduced most of the aerosols after burning moxa. We also found that using an air cleaner was inefficient for controlling indoor air pollutants, particularly gaseous pollutants. Therefore, combining replacing alternative old moxa wools and local exhaust ventilation could be a suitable design for controlling indoor air pollution during moxibustion therapy. PMID:27331817

  13. Controlling Indoor Air Pollution from Moxibustion.

    PubMed

    Lu, Chung-Yen; Kang, Sy-Yuan; Liu, Shu-Hui; Mai, Cheng-Wei; Tseng, Chao-Heng

    2016-06-20

    Indoor air quality (IAQ) control of hospitals plays a critical role in protecting both hospital staffs and patients, particularly those who are highly susceptible to the adverse effects of indoor noxious hazards. However, moxibustion in outpatient departments (OPDs) of traditional Chinese medicine (TCM) may be a source of indoor air pollution in hospitals. Some studies have investigated indoor air pollution during moxibustion in Chinese medicine clinics (CMCs) and moxibustion rooms, demonstrating elevated air pollutants that pose a threat to the health of medical staff and patients. Our study investigated the indoor air pollutants of indoor carbon dioxide (CO₂), carbon monoxide (CO), formaldehyde (HCHO), total volatile organic compounds (TVOCs), airborne particulate matter with a diameter of ≤10 µm (PM10) and ≤2.5 µm (PM2.5) during moxibustion in an acupuncture and moxibustion room of the OPD in a hospital in Taipei. To evaluate the different control strategies for indoor air pollution from moxibution, a comparison of air pollutants during moxibution among the methods of using alternative old moxa wools, local exhaust ventilation and an air cleaner was conducted. In this study, burning alternative old moxa wools for moxibustion obviously reduced all gaseous pollutants except for aerosols comparing burning fresh moxa wools. Using local exhaust ventilation reduced most of the aerosols after burning moxa. We also found that using an air cleaner was inefficient for controlling indoor air pollutants, particularly gaseous pollutants. Therefore, combining replacing alternative old moxa wools and local exhaust ventilation could be a suitable design for controlling indoor air pollution during moxibustion therapy.

  14. Depressive symptoms and indoor tanning among U.S. Hispanic adolescents: Results from a nationally representative sample.

    PubMed

    Gonzales, Manuel; Blashill, Aaron J

    2018-01-01

    To examine the association between depressive symptoms and indoor tanning among U.S. Hispanic adolescents. Data were collected from the 2015 Youth Risk Behavior Survey (YRBS). In the current study, only Hispanic adolescents were included, which yielded a total weighted sample of 2,667 (men: N = 1,368; women: N = 1,299). Gender was also explored as a moderator in the association between depressive symptoms (sadness or hopelessness and suicidality) and indoor tanning. Logistic regressions were used, with past 12 month indoor tanning behavior (0 vs. 1 or more sessions) entered as the dependent variable. Across gender, sadness or hopelessness was associated with increased odds of indoor tanning (OR = 1.8, 95% CI [1.2, 3.0], p = .01); however, gender significantly moderated the association between suicidality and indoor tanning. Simple slope analyses revealed that suicidality was significantly associated with increased odds of indoor tanning only among boys (OR = 4.0, 95% CI [2.1, 7.5], p = .001) whereas a nonsignificant association was found among girls (OR = 0.8, 95% CI [0.4, 1.8], p = .65). Results suggest there is a differential relationship between suicidality and indoor tanning as function of gender among U.S. Hispanic adolescents. Skin cancer prevention programs for Hispanic youth may wish to consider the role of gender and negative affect in targeted campaigns. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  15. EXPOSURE OF CHILDREN TO INDOOR MOLDS

    EPA Science Inventory

    Children now spend more than 90% of their time indoors. Thus, any exposure to indoor pollutants may be critical to their health. Molds are one of the most important pollutants children are exposed to indoors. Molds produce hundreds of allergens and toxins. These products ha...

  16. Determinants of indoor benzene in Europe

    NASA Astrophysics Data System (ADS)

    Lai, H. K.; Jantunen, M. J.; Künzli, N.; Kulinskaya, E.; Colvile, R.; Nieuwenhuijsen, M. J.

    This study identified the key determinants associated with the indoor benzene concentrations that were measured between 1996 and 2000 using the EXPOLIS protocol in the residences of six European cities, including Athens (Greece), Basel (Switzerland), Helsinki (Finland), Milan (Italy), Oxford (United Kingdom), and Prague (Czech Republic). Two consecutive days of home indoor and home outdoor measurements of benzene were carried out at the homes of adult participants on different dates and seasons during the sampling period. Regression models, with interactions searched by all-possible subset method, were used to assess the city effects and the determinants of home indoor benzene (adjusted R2=0.57, n=412). Outdoor benzene concentrations, outdoor temperature, wind speed, the use of anti-moth products, and indoor smoking in terms of number of cigarettes consumed per day were shown to be the key determinants of indoor benzene concentrations. The model was further used to predict the indoor benzene levels in cities. Non-linear relationships were commonly found, indicating that a unit change in the indoor concentration cannot be simply estimated by a proportional change of the determinant, and the pattern of relationships could be differed in different places. This finding is important in formulating indoor air quality guidelines as well as calculating an accurate health risk estimate based on the estimates of population's lifetime exposure levels.

  17. Psychotropic substances in indoor environments.

    PubMed

    Cecinato, Angelo; Romagnoli, Paola; Perilli, Mattia; Patriarca, Claudia; Balducci, Catia

    2014-10-01

    The presence of drugs in outdoor air has been established, but few investigations have been conducted indoors. This study focused on psychotropic substances (PSs) at three schools, four homes and one office in Rome, Italy. The indoor drug concentrations and the relationships with the outdoor atmosphere were investigated. The optimised monitoring procedure allowed for the determination of cocaine, cannabinoids and particulate fractions of nicotine and caffeine. In-field experiments were performed during the winter, spring and summer seasons. Psychotropic substances were observed in all indoor locations. The indoor concentrations often exceeded those recorded both outdoors at the same sites and at the atmospheric pollution control network stations, indicating that the drugs were released into the air at the inside sites or were more persistent. During winter, the relative concentrations of cannabinol, cannabidiol and tetrahydrocannabinol depended on site and indoor/outdoor location at the site. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Detection and tracking of human targets in indoor and urban environments using through-the-wall radar sensors

    NASA Astrophysics Data System (ADS)

    Radzicki, Vincent R.; Boutte, David; Taylor, Paul; Lee, Hua

    2017-05-01

    Radar based detection of human targets behind walls or in dense urban environments is an important technical challenge with many practical applications in security, defense, and disaster recovery. Radar reflections from a human can be orders of magnitude weaker than those from objects encountered in urban settings such as walls, cars, or possibly rubble after a disaster. Furthermore, these objects can act as secondary reflectors and produce multipath returns from a person. To mitigate these issues, processing of radar return data needs to be optimized for recognizing human motion features such as walking, running, or breathing. This paper presents a theoretical analysis on the modulation effects human motion has on the radar waveform and how high levels of multipath can distort these motion effects. From this analysis, an algorithm is designed and optimized for tracking human motion in heavily clutter environments. The tracking results will be used as the fundamental detection/classification tool to discriminate human targets from others by identifying human motion traits such as predictable walking patterns and periodicity in breathing rates. The theoretical formulations will be tested against simulation and measured data collected using a low power, portable see-through-the-wall radar system that could be practically deployed in real-world scenarios. Lastly, the performance of the algorithm is evaluated in a series of experiments where both a single person and multiple people are moving in an indoor, cluttered environment.

  19. Indoor Allergens and Allergic Respiratory Disease

    PubMed Central

    Chapman, Martin D.; Wünschmann, Sabina

    2016-01-01

    Purpose of review The purpose of this review is to evaluate the most recent findings on indoor allergens and their impact on allergic diseases. Recent findings Indoor allergens are present inside buildings (home, work environment, school), and given the chronic nature of the exposures, indoor allergies tend to be associated with the development of asthma. The most common indoor allergens are derived from dust mites, cockroaches, mammals (including wild rodents and pets), and fungi. The advent of molecular biology and proteomics has led to the identification, cloning, and expression of new indoor allergens, which have facilitated research to elucidate their role in allergic diseases. This review is an update on new allergens and their molecular features, together with the most recent reports on their avoidance for allergy prevention and their use for diagnosis and treatment. Summary Research progress on indoor allergens will result in the development of new diagnostic tools and design of coherent strategies for immunotherapy. PMID:27184001

  20. NFC Internal: An Indoor Navigation System

    PubMed Central

    Ozdenizci, Busra; Coskun, Vedat; Ok, Kerem

    2015-01-01

    Indoor navigation systems have recently become a popular research field due to the lack of GPS signals indoors. Several indoors navigation systems have already been proposed in order to eliminate deficiencies; however each of them has several technical and usability limitations. In this study, we propose NFC Internal, a Near Field Communication (NFC)-based indoor navigation system, which enables users to navigate through a building or a complex by enabling a simple location update, simply by touching NFC tags those are spread around and orient users to the destination. In this paper, we initially present the system requirements, give the design details and study the viability of NFC Internal with a prototype application and a case study. Moreover, we evaluate the performance of the system and compare it with existing indoor navigation systems. It is seen that NFC Internal has considerable advantages and significant contributions to existing indoor navigation systems in terms of security and privacy, cost, performance, robustness, complexity, user preference and commercial availability. PMID:25825976

  1. Bim-Based Indoor Path Planning Considering Obstacles

    NASA Astrophysics Data System (ADS)

    Xu, M.; Wei, S.; Zlatanova, S.; Zhang, R.

    2017-09-01

    At present, 87 % of people's activities are in indoor environment; indoor navigation has become a research issue. As the building structures for people's daily life are more and more complex, many obstacles influence humans' moving. Therefore it is essential to provide an accurate and efficient indoor path planning. Nowadays there are many challenges and problems in indoor navigation. Most existing path planning approaches are based on 2D plans, pay more attention to the geometric configuration of indoor space, often ignore rich semantic information of building components, and mostly consider simple indoor layout without taking into account the furniture. Addressing the above shortcomings, this paper uses BIM (IFC) as the input data and concentrates on indoor navigation considering obstacles in the multi-floor buildings. After geometric and semantic information are extracted, 2D and 3D space subdivision methods are adopted to build the indoor navigation network and to realize a path planning that avoids obstacles. The 3D space subdivision is based on triangular prism. The two approaches are verified by the experiments.

  2. Efficacy of a novel mode of action of an indoor residual spraying product, SumiShield® 50WG against susceptible and resistant populations of Anopheles gambiae (s.l.) in Benin, West Africa.

    PubMed

    Agossa, Fiacre R; Padonou, Gil G; Koukpo, Come Z; Zola-Sahossi, Jacques; Azondekon, Roseric; Akuoko, Osei K; Ahoga, Juniace; N'dombidje, Boris; Akinro, Bruno; Fassinou, Arsene Jacques Y H; Sezonlin, Michel; Akogbeto, Martin C

    2018-05-10

    Scale-up of the distribution of long-lasting insecticide-treated bed nets and indoor residual spraying with insecticides over the last decade have contributed to the considerable decrease of malaria morbidity and mortality in sub-Saharan Africa. Due to the increasing pyrethroid resistance intensity and the spread of carbamate resistance in Anopheles gambiae (s.s.) mosquitoes and the limited number of insecticides recommended by the WHO for vector control, alternative insecticide formulations for IRS with long-lasting residual activity are required to sustain the gains obtained in most malaria-endemic countries. SumiShield 50WG (clothianidin 300 mg ai/m 2 ) developed by Sumitomo Chemical was evaluated alongside deltamethrin 25 mg ai/m 2 (K-Othrine 250 WG) against a pyrethroid resistant Anopheles gambiae (s.l.) population in experimental huts in Covè, Benin. Residual activity was also tested in cone bioassays with the susceptible An. gambiae "Kisumu" strain and the local wild resistant population. The results showed very low toxicity from deltamethrin (mortality rates ranged between 1-40%) against host-seeking resistant Anopheles populations. SumiShield in contrast gave an overall mean mortality of 91.7% at the 120 h observation across the eight- month observation period following spraying. The residual activity measured using cone tests was over the 80% WHO threshold for 24 weeks for resistant wild Anopheles population and 32 weeks for the susceptible strain "Kisumu" after the spraying. SumiShield is a good candidate for IRS in areas of permanent malaria transmission and where Anopheles populations are resistant to other conventional insecticides such as pyrethroids. It would be interesting to complete experimental huts studies by assessing the efficacy and residual effect of SumiShield 50WG at community level (small-scale field testing) in an area where vectors are highly resistant to insecticides.

  3. Indoor Air Quality in Schools

    EPA Pesticide Factsheets

    This web site will educate the public about indoor environmental issues specific to educational facilities and the importance of developing and sustaining comprehensive indoor air quality management programs.

  4. Indoor air pollution in developing countries: a major environmental and public health challenge.

    PubMed Central

    Bruce, N.; Perez-Padilla, R.; Albalak, R.

    2000-01-01

    Around 50% of people, almost all in developing countries, rely on coal and biomass in the form of wood, dung and crop residues for domestic energy. These materials are typically burnt in simple stoves with very incomplete combustion. Consequently, women and young children are exposed to high levels of indoor air pollution every day. There is consistent evidence that indoor air pollution increases the risk of chronic obstructive pulmonary disease and of acute respiratory infections in childhood, the most important cause of death among children under 5 years of age in developing countries. Evidence also exists of associations with low birth weight, increased infant and perinatal mortality, pulmonary tuberculosis, nasopharyngeal and laryngeal cancer, cataract, and, specifically in respect of the use of coal, with lung cancer. Conflicting evidence exists with regard to asthma. All studies are observational and very few have measured exposure directly, while a substantial proportion have not dealt with confounding. As a result, risk estimates are poorly quantified and may be biased. Exposure to indoor air pollution may be responsible for nearly 2 million excess deaths in developing countries and for some 4% of the global burden of disease. Indoor air pollution is a major global public health threat requiring greatly increased efforts in the areas of research and policy-making. Research on its health effects should be strengthened, particularly in relation to tuberculosis and acute lower respiratory infections. A more systematic approach to the development and evaluation of interventions is desirable, with clearer recognition of the interrelationships between poverty and dependence on polluting fuels. PMID:11019457

  5. Home interventions are effective at decreasing indoor nitrogen dioxide concentrations.

    PubMed

    Paulin, L M; Diette, G B; Scott, M; McCormack, M C; Matsui, E C; Curtin-Brosnan, J; Williams, D L; Kidd-Taylor, A; Shea, M; Breysse, P N; Hansel, N N

    2014-08-01

    Nitrogen dioxide (NO2 ), a by-product of combustion produced by indoor gas appliances such as cooking stoves, is associated with respiratory symptoms in those with obstructive airways disease. We conducted a three-armed randomized trial to evaluate the efficacy of interventions aimed at reducing indoor NO2 concentrations in homes with unvented gas stoves: (i) replacement of existing gas stove with electric stove; (ii) installation of ventilation hood over existing gas stove; and (iii) placement of air purifiers with high-efficiency particulate air (HEPA) and carbon filters. Home inspection and NO2 monitoring were conducted at 1 week pre-intervention and at 1 week and 3 months post-intervention. Stove replacement resulted in a 51% and 42% decrease in median NO2 concentration at 3 months of follow-up in the kitchen and bedroom, respectively (P = 0.01, P = 0.01); air purifier placement resulted in an immediate decrease in median NO2 concentration in the kitchen (27%, P < 0.01) and bedroom (22%, P = 0.02), but at 3 months, a significant reduction was seen only in the kitchen (20%, P = 0.05). NO2 concentrations in the kitchen and bedroom did not significantly change following ventilation hood installation. Replacing unvented gas stoves with electric stoves or placement of air purifiers with HEPA and carbon filters can decrease indoor NO2 concentrations in urban homes. Several combustion sources unique to the residential indoor environment, including gas stoves, produce nitrogen dioxide (NO2), and higher NO2 concentrations, are associated with worse respiratory morbidity in people with obstructive lung disease. A handful of studies have modified the indoor environment by replacing unvented gas heaters; this study, to our knowledge, is the first randomized study to target unvented gas stoves. The results of this study show that simple home interventions, including replacement of an unvented gas stove with an electric stove or placement of HEPA air purifiers with carbon

  6. I/O values for determination of the origin of some indoor organic pollutants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Otson, R.; Zhu, J.

    To reduce human health risks resulting from exposure to toxic chemicals, it is important to determine the origin of such substances. The ratio (I/O) of indoor to outdoor concentrations of selected airborne vapor phase organic compounds (VPOC) was used to estimate the contribution of indoor sources to levels of the compounds in the air of 44 homes selected randomly in the Greater Toronto Area (GTA). Average I/O values for all of the homes were greater 1.5 for 10 of the 20 detected target compounds, and it could be concluded that indoor VPOC sources had a greater impact on indoor airmore » quality than outdoor air in these instances. A significant finding, which aptly demonstrates the importance of indoor sources and pollution, was the overall I/O value of 5.2 for the 44 representative GTA homes. Possible indoor sources for most of the 10 compounds could be identified, based on information collected by means of a questionnaire, as well as from the scientific literature. However, possible sources for some compounds could not be determined as readily, probably because of the presence of multiple sources, and sources which had not been previously noted, such as foods and beverages. The sensitivity of I/O values to various factors (e.g., source strength, air exchange rates, precision of measurements, unanticipated sources), and the reliability of determining the origin of pollutants by use of I/O values alone were examined, with some examples. If used judiciously, the I/O value can be a useful tool for IAQ investigations.« less

  7. Managing Indoor Air Quality in Schools.

    ERIC Educational Resources Information Center

    Woolums, Jennifer

    This publication examines the causes and effects of poor indoor air quality and provides information for reducing exposure to indoor contaminants in schools. It discusses the various indoor pollutants found in schools, including dust, chemical agents, gases, and volatile organic compounds; where they are found in schools; and their health effects…

  8. Indoor localization using magnetic fields

    NASA Astrophysics Data System (ADS)

    Pathapati Subbu, Kalyan Sasidhar

    Indoor localization consists of locating oneself inside new buildings. GPS does not work indoors due to multipath reflection and signal blockage. WiFi based systems assume ubiquitous availability and infrastructure based systems require expensive installations, hence making indoor localization an open problem. This dissertation consists of solving the problem of indoor localization by thoroughly exploiting the indoor ambient magnetic fields comprising mainly of disturbances termed as anomalies in the Earth's magnetic field caused by pillars, doors and elevators in hallways which are ferromagnetic in nature. By observing uniqueness in magnetic signatures collected from different campus buildings, the work presents the identification of landmarks and guideposts from these signatures and further develops magnetic maps of buildings - all of which can be used to locate and navigate people indoors. To understand the reason behind these anomalies, first a comparison between the measured and model generated Earth's magnetic field is made, verifying the presence of a constant field without any disturbances. Then by modeling the magnetic field behavior of different pillars such as steel reinforced concrete, solid steel, and other structures like doors and elevators, the interaction of the Earth's field with the ferromagnetic fields is described thereby explaining the causes of the uniqueness in the signatures that comprise these disturbances. Next, by employing the dynamic time warping algorithm to account for time differences in signatures obtained from users walking at different speeds, an indoor localization application capable of classifying locations using the magnetic signatures is developed solely on the smart phone. The application required users to walk short distances of 3-6 m anywhere in hallway to be located with accuracies of 80-99%. The classification framework was further validated with over 90% accuracies using model generated magnetic signatures representing

  9. Socio-economic inequity in demand for insecticide-treated nets, in-door residual house spraying, larviciding and fogging in Sudan.

    PubMed

    Onwujekwe, Obinna; Malik, El-Fatih Mohamed; Mustafa, Sara Hassan; Mnzava, Abraham

    2005-12-15

    In order to optimally prioritize and use public and private budgets for equitable malaria vector control, there is a need to determine the level and determinants of consumer demand for different vector control tools. To determine the demand from people of different socio-economic groups for indoor residual house-spraying (IRHS), insecticide-treated nets (ITNs), larviciding with chemicals (LWC), and space spraying/fogging (SS) and the disease control implications of the result. Ratings and levels of willingness-to-pay (WTP) for the vector control tools were determined using a random cross-sectional sample of 720 householdes drawn from two states. WTP was elicited using the bidding game. An asset-based socio-economic status (SES) index was used to explore whether WTP was related to SES of the respondents. IRHS received the highest proportion of highest preferred rating (41.0%) followed by ITNs (23.1%). However, ITNs had the highest mean WTP followed by IRHS, while LWC had the least. The regression analysis showed that SES was positively and statistically significantly related to WTP across the four vector control tools and that the respondents' rating of IRHS and ITNs significantly explained their levels of WTP for the two tools. People were willing to pay for all the vector-control tools, but the demand for the vector control tools was related to the SES of the respondents. Hence, it is vital that there are public policies and financing mechanisms to ensure equitable provision and utilisation of vector control tools, as well as protecting the poor from cost-sharing arrangements.

  10. Indoor air quality in homes, offices and restaurants in Korean urban areas—indoor/outdoor relationships

    NASA Astrophysics Data System (ADS)

    Baek, Sung-Ok; Kim, Yoon-Shin; Perry, Roger

    Air quality monitoring was carried out to collect data on the levels of various indoor and ambient air constituents in two cities in Korea (Seoul and Taegu). Sampling was conducted simultaneously indoors and outdoors at six residences, six offices and six restaurants in each city during summer 1994 and winter 1994-1995. Measured pollutants were respirable suspended particulate matter (RSP), carbon monoxide (CO), carbon dioxide (CO 2), nitrogen dioxide (NO 2), and a range of volatile organic compounds (VOCs). In addition, in order to evaluate the effect of smoking on indoor air quality, analyses of parameters associated with environmental tobacco smoke (ETS) were undertaken, which are nicotine, ultraviolet (UVPM), fluorescence (FPM) and solanesol particulate matter (SolPM). The results of this study have confirmed the importance of ambient air in determining the quality of air indoors in two major Korean cities. The majority of VOCs measured in both indoor and outdoor environments were derived from outdoor sources, probably motor vehicles. Benzene and other VOC concentrations were much higher during the winter months than the summer months and were not significantly greater in the smoking sites examined. Heating and cooking practices, coupled with generally inadequate ventilation, also were shown to influence indoor air quality. In smoking sites, ETS appears to be a minor contributor to VOC levels as no statistically significant relationships were identified with ETS components and VOCs, whereas very strong correlations were found between indoor and outdoor levels of vehicle-related pollutants. The average contribution of ETS to total RSP concentrations was estimated to range from 10 to 20%.

  11. Fundamentals of Indoor Air Quality in Buildings

    EPA Pesticide Factsheets

    This module provides the fundamentals to understanding indoor air quality. It provides a rudimentary framework for understanding how indoor and outdoor sources of pollution affect the indoor air quality of buildings.

  12. An indoor chemical cocktail

    NASA Astrophysics Data System (ADS)

    Gligorovski, Sasho; Abbatt, Jonathan P. D.

    2018-02-01

    In the past 50 years, many of the contaminants and chemical transformations that occur in outdoor waters, soils, and air have been elucidated. However, the chemistry of the indoor environment in which we live most of the time—up to 90% in some societies—is not nearly as well studied. Recent work has highlighted the wealth of chemical transformations that occur indoors. This chemistry is associated with 3 of the top 10 risk factors for negative health outcomes globally: household air pollution from solid fuels, tobacco smoking, and ambient particulate matter pollution (1). Assessments of human exposure to indoor pollutants must take these reactive processes into consideration.

  13. Indoor Radon Concentration Related to Different Radon Areas and Indoor Radon Prediction

    NASA Astrophysics Data System (ADS)

    Juhásová Šenitková, Ingrid; Šál, Jiří

    2017-12-01

    Indoor radon has been observed in the buildings at areas with different radon risk potential. Preventive measures are based on control of main potential radon sources (soil gas, building material and supplied water) to avoid building of new houses above recommended indoor radon level 200 Bq/m3. Radon risk (index) estimation of individual building site bedrock in case of new house siting and building protection according technical building code are obligatory. Remedial actions in buildings built at high radon risk areas were carried out principally by unforced ventilation and anti-radon insulation. Significant differences were found in the level of radon concentration between rooms where radon reduction techniques were designed and those where it was not designed. The mathematical model based on radon exhalation from soil has been developed to describe the physical processes determining indoor radon concentration. The model is focused on combined radon diffusion through the slab and advection through the gap from sub-slab soil. In this model, radon emanated from building materials is considered not having a significant contribution to indoor radon concentration. Dimensional analysis and Gauss-Newton nonlinear least squares parametric regression were used to simplify the problem, identify essential input variables and find parameter values. The presented verification case study is introduced for real buildings with respect to various underground construction types. Presented paper gives picture of possible mathematical approach to indoor radon concentration prediction.

  14. Reducing indoor residential exposures to outdoor pollutants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sherman, Max H.; Matson, Nance E.

    2003-07-01

    The basic strategy for providing indoor air quality in residences is to dilute indoor sources with outdoor air. This strategy assumes that the outdoor air does not have pollutants at harmful levels or that the outdoor air is, at least, less polluted than the indoor air. When this is not the case, different strategies need to be employed to ensure adequate air quality in the indoor environment. These strategies include ventilation systems, filtration and other measures. These strategies can be used for several types of outdoor pollution, including smog, particulates and toxic air pollutants. This report reviews the impacts thatmore » typical outdoor air pollutants can have on the indoor environment and provides design and operational guidance for mitigating them. Poor quality air cannot be used for diluting indoor contaminants, but more generally it can become an indoor contaminant itself. This paper discusses strategies that use the building as protection against potentially hazardous outdoor pollutants, including widespread pollutants, accidental events, and potential attacks.« less

  15. A longitudinal test of the Comprehensive Indoor Tanning Expectations Scale: The importance of affective beliefs in predicting indoor tanning behavior.

    PubMed

    Myrick, Jessica Gall; Noar, Seth M; Kelley, Dannielle; Zeitany, Alexandra E; Morales-Pico, Brenda M; Thomas, Nancy E

    2017-01-01

    In order to better understand drivers of dangerous indoor tanning behaviors, researchers developed the Comprehensive Indoor Tanning Expectations scale. To examine the longitudinal effectiveness of Comprehensive Indoor Tanning Expectations, we surveyed young women in the Southeastern United States at two time points ( N = 553). The scale demonstrated strong test-retest reliability. Participants who believed indoor tanning would improve their mood and afford social approval were significantly more likely to tan 6 months later, while participants who believed indoor tanning leads to psychological/physical discomfort were significantly less likely to tan 6 months later. Knowing the psychological bases for indoor tanning can inform intervention and message design.

  16. Assessment of tobacco heating product THP1.0. Part 4: Characterisation of indoor air quality and odour.

    PubMed

    Forster, Mark; McAughey, John; Prasad, Krishna; Mavropoulou, Eleni; Proctor, Christopher

    2018-03-01

    The tobacco heating product THP1.0, which heats but does not burn tobacco, was tested as part of a modified-risk tobacco product assessment framework for its impacts on indoor air quality and residual tobacco smoke odour. THP1.0 heats the tobacco to less than 240 °C ± 5 °C during puffs. An environmentally controlled room was used to simulate ventilation conditions corresponding to residential, office and hospitality environments. An analysis of known tobacco smoke constituents, included CO, CO 2 , NO, NO 2 , nicotine, glycerol, 3-ethenyl pyridine, sixteen polycyclic aromatic hydrocarbons, eight volatile organic compounds, four carbonyls, four tobacco-specific nitrosamines and total aerosol particulate matter. Significant emissions reductions in comparison to conventional cigarettes were measured for THP1.0. Levels of nicotine, acetaldehyde, formaldehyde and particulate matter emitted from THP1.0 exceeded ambient air measurements, but were more than 90% reduced relative to cigarette smoke emissions within the laboratory conditions defined Residual tobacco smoke odour was assessed by trained sensory panels after exposure of cloth, hair and skin to both mainstream and environmental emissions from the test products. Residual tobacco smoke odour was significantly lower from THP1.0 than from a conventional cigarette. These data show that using THP1.0 has the potential to result in considerably reduced environmental emissions that affect indoor air quality relative to conventional cigarettes. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  17. Coordinate references for the indoor/outdoor seamless positioning

    NASA Astrophysics Data System (ADS)

    Ruan, Ling; Zhang, Ling; Long, Yi; Cheng, Fei

    2018-05-01

    Indoor positioning technologies are being developed rapidly, and seamless positioning which connected indoor and outdoor space is a new trend. The indoor and outdoor positioning are not applying the same coordinate system and different indoor positioning scenes uses different indoor local coordinate reference systems. A specific and unified coordinate reference frame is needed as the space basis and premise in seamless positioning application. Trajectory analysis of indoor and outdoor integration also requires a uniform coordinate reference. However, the coordinate reference frame in seamless positioning which can applied to various complex scenarios is lacking of research for a long time. In this paper, we proposed a universal coordinate reference frame in indoor/outdoor seamless positioning. The research focus on analysis and classify the indoor positioning scenes and put forward the coordinate reference system establishment and coordinate transformation methods in each scene. And, through some experiments, the calibration method feasibility was verified.

  18. Indoor Air Quality Manual.

    ERIC Educational Resources Information Center

    Baldwin Union Free School District, NY.

    This manual identifies ways to improve a school's indoor air quality (IAQ) and discusses practical actions that can be carried out by school staff in managing air quality. The manual includes discussions of the many sources contributing to school indoor air pollution and the preventive planning for each including renovation and repair work,…

  19. The impact of indoor tanning legislation: newspaper coverage of the risks of indoor tanning before and after the California indoor tanning ban for minors.

    PubMed

    Mayer, Jonathan E; Swetter, Susan M; Guild, Samantha; Geller, Alan C

    2015-03-01

    On June 1, 2011, the California Senate passed a bill banning minors from indoor tanning. We aimed to determine whether the bill's passage was associated with longer-term media coverage regarding skin protection and the risks associated with indoor tanning. Articles from 31 English-language California newspapers between June 2010-May 2011 (PRE) and June 2011-May 2012 (POST) were searched using terms related to skin protection. Ninety articles were found for in-depth coding and analysis. There were more skin protection articles in the POST period than in the PRE period (57 vs 33; p < .05). In addition, there were more POST articles mentioning the risks of indoor tanning (33 vs 10; p < .001), and a POST article was more likely to mention the risks (58 vs 30%; p < .05). The higher number of POST articles mentioning the risks persisted throughout all quarters. Therefore, the California indoor tanning ban was associated with increased longer-term news coverage of skin protection and the risks associated with indoor tanning. This finding has potential influence on the many states that are considering comparable legislation.

  20. PILOT STUDY OF THE POTENTIAL FOR HUMAN EXPOSURES TO PET-BORNE DIAZINON RESIDUES FOLLOWING LAWN APPLICATIONS IN NORTH CAROLINA

    EPA Science Inventory

    This study examined the potential for indoor/outdoor pet dogs to be an important pathway for transporting diazinon residues into homes and onto occupants following residential lawn applications. The primary objective was to investigate the potential exposures of children and thei...

  1. A review of semi-volatile organic compounds (SVOCs) in the indoor environment: occurrence in consumer products, indoor air and dust.

    PubMed

    Lucattini, Luisa; Poma, Giulia; Covaci, Adrian; de Boer, Jacob; Lamoree, Marja H; Leonards, Pim E G

    2018-06-01

    As many people spend a large part of their life indoors, the quality of the indoor environment is important. Data on contaminants such as flame retardants, pesticides and plasticizers are available for indoor air and dust but are scarce for consumer products such as computers, televisions, furniture, carpets, etc. This review presents information on semi-volatile organic compounds (SVOCs) in consumer products in an attempt to link the information available for chemicals in indoor air and dust with their indoor sources. A number of 256 papers were selected and divided among SVOCs found in consumer products (n = 57), indoor dust (n = 104) and air (n = 95). Concentrations of SVOCs in consumer products, indoor dust and air are reported (e.g. PFASs max: 13.9 μg/g in textiles, 5.8 μg/kg in building materials, 121 ng/g in house dust and 6.4 ng/m 3 in indoor air). Most of the studies show common aims, such as human exposure and risk assessment. The main micro-environments investigated (houses, offices and schools) reflect the relevance of indoor air quality. Most of the studies show a lack of data on concentrations of chemicals in consumer goods and often only the presence of chemicals is reported. At the moment this is the largest obstacle linking chemicals in products to chemicals detected in indoor air and dust. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  2. Quantification and aging of the post-blast residue of TNT landmines.

    PubMed

    Oxley, Jimmie C; Smith, James L; Resende, Elmo; Pearce, Evan

    2003-07-01

    Post-blast residues are potential interferents to chemical detection of landmines. To assess the potential problem related to 2,4,6-trinitrotoluene (TNT), its post-blast residue was identified and quantified. In the first part of this study laboratory-scale samples of TNT (2 g) were detonated in a small-scale explosivity device (SSED) to evaluate the explosive power and collect post-blast residue for chemical analysis. Initiator size was large relative to the TNT charge; thus, issues arose regarding choice of initiator, residue from the initiator, and afterburning of TNT. The second part of this study detonated 75 to 150 g of military-grade TNT (typical of antipersonnel mines) in 55-gal barrels containing various witness materials (metal plates, sand, barrel walls, the atmosphere). The witness materials were analyzed for explosive residue. In a third set of tests, 75-g samples of TNT were detonated over soil (from Fort Leonard Wood or Sandia National Laboratory) in an indoor firing chamber (100 by 4.6 by 2.7 m high). Targeted in these studies were TNT and four explosive-related compounds (ERC): 2,4-dinitrotoluene (DNT), 1,3-dinitrobenzene (DNB), 2- and 4-aminodinitrotoluene (2-ADNT and 4-ADNT). The latter two are microbial degradation products of TNT. Post-blast residue was allowed to age in the soils as a function of moisture contents (5 and 10%) in order to quantify the rate of degradation of the principal residues (TNT, DNT, and DNB) and formation of the TNT microbial degradation products (2-ADNT and 4-ADNT). The major distinction between landmine leakage and post-blast residue was not the identity of the species but relative ratios of amounts. In landmine leakage the DNT/TNT ratio was usually greater than 1. In post-blast residue it was on the order of 1 to 1/100th of a percent, and the total amount of pre-blast residue (landmine leakage) was a factor of 1/100 to 1/1000 less than post-blast. In addition, landmine leakage resulted in low DNT/ADNT ratios, usually

  3. Indoor air quality in Brazilian universities.

    PubMed

    Jurado, Sonia R; Bankoff, Antônia D P; Sanchez, Andrea

    2014-07-11

    This study evaluated the indoor air quality in Brazilian universities by comparing thirty air-conditioned (AC) (n = 15) and naturally ventilated (NV) (n = 15) classrooms. The parameters of interest were indoor carbon dioxide (CO2), temperature, relative humidity (RH), wind speed, viable mold, and airborne dust levels. The NV rooms had larger concentration of mold than the AC rooms (1001.30 ± 125.16 and 367.00 ± 88.13 cfu/m3, respectively). The average indoor airborne dust concentration exceeded the Brazilian standards (<80 µg/m3) in both NV and AC classrooms. The levels of CO2 in the AC rooms were significantly different from the NV rooms (1433.62 ± 252.80 and 520.12 ± 37.25 ppm, respectively). The indoor air quality in Brazilian university classrooms affects the health of students. Therefore, indoor air pollution needs to be considered as an important public health problem.

  4. A Hybrid 3D Indoor Space Model

    NASA Astrophysics Data System (ADS)

    Jamali, Ali; Rahman, Alias Abdul; Boguslawski, Pawel

    2016-10-01

    GIS integrates spatial information and spatial analysis. An important example of such integration is for emergency response which requires route planning inside and outside of a building. Route planning requires detailed information related to indoor and outdoor environment. Indoor navigation network models including Geometric Network Model (GNM), Navigable Space Model, sub-division model and regular-grid model lack indoor data sources and abstraction methods. In this paper, a hybrid indoor space model is proposed. In the proposed method, 3D modeling of indoor navigation network is based on surveying control points and it is less dependent on the 3D geometrical building model. This research proposes a method of indoor space modeling for the buildings which do not have proper 2D/3D geometrical models or they lack semantic or topological information. The proposed hybrid model consists of topological, geometrical and semantical space.

  5. VOC source identification from personal and residential indoor, outdoor and workplace microenvironment samples in EXPOLIS-Helsinki, Finland

    NASA Astrophysics Data System (ADS)

    Edwards, Rufus D.; Jurvelin, J.; Koistinen, K.; Saarela, K.; Jantunen, M.

    Principal component analyses (varimax rotation) were used to identify common sources of 30 target volatile organic compounds (VOCs) in residential outdoor, residential indoor and workplace microenvironment and personal 48-h exposure samples, as a component of the EXPOLIS-Helsinki study. Variability in VOC concentrations in residential outdoor microenvironments was dominated by compounds associated with long-range transport of pollutants, followed by traffic emissions, emissions from trees and product emissions. Variability in VOC concentrations in environmental tobacco smoke (ETS) free residential indoor environments was dominated by compounds associated with indoor cleaning products, followed by compounds associated with traffic emissions, long-range transport of pollutants and product emissions. Median indoor/outdoor ratios for compounds typically associated with traffic emissions and long-range transport of pollutants exceeded 1, in some cases quite considerably, indicating substantial indoor source contributions. Changes in the median indoor/outdoor ratios during different seasons reflected different seasonal ventilation patterns as increased ventilation led to dilution of those VOC compounds in the indoor environment that had indoor sources. Variability in workplace VOC concentrations was dominated by compounds associated with traffic emissions followed by product emissions, long-range transport and air fresheners. Variability in VOC concentrations in ETS free personal exposure samples was dominated by compounds associated with traffic emissions, followed by long-range transport, cleaning products and product emissions. VOC sources in personal exposure samples reflected the times spent in different microenvironments, and personal exposure samples were not adequately represented by any one microenvironment, demonstrating the need for personal exposure sampling.

  6. A ventilation intervention study in classrooms to improve indoor air quality: the FRESH study

    PubMed Central

    2013-01-01

    Background Classroom ventilation rates often do not meet building standards, although it is considered to be important to improve indoor air quality. Poor indoor air quality is thought to influence both children’s health and performance. Poor ventilation in The Netherlands most often occurs in the heating season. To improve classroom ventilation a tailor made mechanical ventilation device was developed to improve outdoor air supply. This paper studies the effect of this intervention. Methods The FRESH study (Forced-ventilation Related Environmental School Health) was designed to investigate the effect of a CO2 controlled mechanical ventilation intervention on classroom CO2 levels using a longitudinal cross-over design. Target CO2 concentrations were 800 and 1200 parts per million (ppm), respectively. The study included 18 classrooms from 17 schools from the north-eastern part of The Netherlands, 12 experimental classrooms and 6 control classrooms. Data on indoor levels of CO2, temperature and relative humidity were collected during three consecutive weeks per school during the heating seasons of 2010–2012. Associations between the intervention and weekly average indoor CO2 levels, classroom temperature and relative humidity were assessed by means of mixed models with random school-effects. Results At baseline, mean CO2 concentration for all schools was 1335 ppm (range: 763–2000 ppm). The intervention was able to significantly decrease CO2 levels in the intervention classrooms (F (2,10) = 17.59, p < 0.001), with a mean decrease of 491 ppm. With the target set at 800 ppm, mean CO2 was 841 ppm (range: 743–925 ppm); with the target set at 1200 ppm, mean CO2 was 975 ppm (range: 887–1077 ppm). Conclusions Although the device was not capable of precisely achieving the two predefined levels of CO2, our study showed that classroom CO2 levels can be reduced by intervening on classroom ventilation using a CO2 controlled mechanical ventilation system

  7. A ventilation intervention study in classrooms to improve indoor air quality: the FRESH study.

    PubMed

    Rosbach, Jeannette T M; Vonk, Machiel; Duijm, Frans; van Ginkel, Jan T; Gehring, Ulrike; Brunekreef, Bert

    2013-12-17

    Classroom ventilation rates often do not meet building standards, although it is considered to be important to improve indoor air quality. Poor indoor air quality is thought to influence both children's health and performance. Poor ventilation in The Netherlands most often occurs in the heating season. To improve classroom ventilation a tailor made mechanical ventilation device was developed to improve outdoor air supply. This paper studies the effect of this intervention. The FRESH study (Forced-ventilation Related Environmental School Health) was designed to investigate the effect of a CO2 controlled mechanical ventilation intervention on classroom CO2 levels using a longitudinal cross-over design. Target CO2 concentrations were 800 and 1200 parts per million (ppm), respectively. The study included 18 classrooms from 17 schools from the north-eastern part of The Netherlands, 12 experimental classrooms and 6 control classrooms. Data on indoor levels of CO2, temperature and relative humidity were collected during three consecutive weeks per school during the heating seasons of 2010-2012. Associations between the intervention and weekly average indoor CO2 levels, classroom temperature and relative humidity were assessed by means of mixed models with random school-effects. At baseline, mean CO2 concentration for all schools was 1335 ppm (range: 763-2000 ppm). The intervention was able to significantly decrease CO2 levels in the intervention classrooms (F (2,10) = 17.59, p < 0.001), with a mean decrease of 491 ppm. With the target set at 800 ppm, mean CO2 was 841 ppm (range: 743-925 ppm); with the target set at 1200 ppm, mean CO2 was 975 ppm (range: 887-1077 ppm). Although the device was not capable of precisely achieving the two predefined levels of CO2, our study showed that classroom CO2 levels can be reduced by intervening on classroom ventilation using a CO2 controlled mechanical ventilation system.

  8. Development of analysis of volatile polyfluorinated alkyl substances in indoor air using thermal desorption-gas chromatography-mass spectrometry.

    PubMed

    Wu, Yaoxing; Chang, Victor W-C

    2012-05-18

    The study attempts to utilize thermal desorption (TD) coupled with gas chromatography-mass spectrometry (GC-MS) for determination of indoor airborne volatile polyfluorinated alkyl substances (PFASs), including four fluorinated alcohols (FTOHs), two fluorooctane sulfonamides (FOSAs), and two fluorooctane sulfonamidoethanols (FOSEs). Standard stainless steel tubes of Tenax/Carbograph 1 TD were employed for low-volume sampling and exhibited minimal breakthrough of target analytes in sample collection. The method recoveries were in the range of 88-119% for FTOHs, 86-138% for FOSAs, exhibiting significant improvement compared with other existing air sampling methods. However, the widely reported high method recoveries of FOSEs were also observed (139-210%), which was probably due to the structural differences between FOSEs and internal standards. Method detection limit, repeatability, linearity, and accuracy were reported as well. The approach has been successfully applied to routine quantification of targeted PFASs in indoor environment of Singapore. The significantly shorter sampling time enabled the observation of variations of concentrations of targeted PFASs within different periods of a day, with higher concentration levels at night while ventilation systems were shut off. This indicated the existence of indoor sources and the importance of building ventilation and air conditioning system. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. A targeted mass spectrometry-based approach for the identification and characterization of proteins containing α-aminoadipic and γ-glutamic semialdehyde residues

    PubMed Central

    Chavez, Juan D.; Bisson, William H.

    2011-01-01

    The site-specific identification of α-aminoadipic semialdehyde (AAS) and γ-glutamic semialdehyde (GGS) residues in proteins is reported. Semialdehydic protein modifications result from the metal-catalyzed oxidation of Lys or Arg and Pro residues, respectively. Most of the analytical methods for the analysis of protein carbonylation measure change to the global level of carbonylation and fail to provide details regarding protein identity, site, and chemical nature of the carbonylation. In this work, we used a targeted approach, which combines chemical labeling, enrichment, and tandem mass spectrometric analysis, for the site-specific identification of AAS and GGS sites in proteins. The approach is applied to in vitro oxidized glyceraldehyde-3-phosphate dehydrogenase (GAPDH) and an untreated biological sample, namely cardiac mitochondrial proteins. The analysis of GAPDH resulted in the site-specific identification of two AAA and four GGS residues. Computational evaluation of the identified AAS and GGS sites in GAPDH indicated that these sites are located in flexible regions, show high solvent accessibility values, and are in proximity with possible metal ion binding sites. The targeted proteomic analysis of semialdehydic modifications in cardiac mitochondria yielded nine AAS modification sites which were unambiguously assigned to distinct lysine residues in the following proteins: ATP/ATP translocase isoforms 1 and 2, ubiquinol cytochrome-c reductase core protein 2, and ATP synthase α-subunit. PMID:20957471

  10. Plants for Sustainable Improvement of Indoor Air Quality.

    PubMed

    Brilli, Federico; Fares, Silvano; Ghirardo, Andrea; de Visser, Pieter; Calatayud, Vicent; Muñoz, Amalia; Annesi-Maesano, Isabella; Sebastiani, Federico; Alivernini, Alessandro; Varriale, Vincenzo; Menghini, Flavio

    2018-06-01

    Indoor pollution poses a serious threat to human health. Plants represent a sustainable but underexploited solution to enhance indoor air quality. However, the current selection of plants suitable for indoors fails to consider the physiological processes and mechanisms involved in phytoremediation. Therefore, the capacity of plants to remove indoor air pollutants through stomatal uptake (absorption) and non-stomatal deposition (adsorption) remains largely unknown. Moreover, the effects of the indoor plant-associated microbiome still need to be fully analyzed. Here, we discuss how a combination of the enhanced phytoremediation capacity of plants together with cutting-edge air-cleaning and smart sensor technologies can improve indoor life while reducing energy consumption. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Analysis of isocyanates in indoor dust.

    PubMed

    Bekki, Kanae; Uchiyama, Shigehisa; Kunugita, Naoki

    2018-05-04

    Isocyanates are harmful semi-volatile organic compounds that are emitted from various consumer products like polyurethane foam-based mattresses. Although it is a concern that isocyanates might accumulate in indoor dust, causing infants and toddlers, in particular, to be exposed to them, little information is available on the levels of isocyanates in the indoor environment. In this study, we investigated the suitability of an analytical method for determining the presence and level of isocyanates in the indoor dust. The method we developed displayed acceptable linearity, accuracy, and precision in the analysis of eleven different isocyanates. By using this analytical method, we could detect five isocyanates (ICA, MIC, EIC, PIC, and PHI) and quantify three isocyanates (MIC, EIC, and PHI) in indoor dust collected in different houses. This study is the first to focus on the pollution of indoor dust by isocyanates, and the tested method is suitable for the estimation of the level of isocyanate exposure. Graphical abstract ᅟ.

  12. Indoor Air Quality in Brazilian Universities

    PubMed Central

    Jurado, Sonia R.; Bankoff, Antônia D. P.; Sanchez, Andrea

    2014-01-01

    This study evaluated the indoor air quality in Brazilian universities by comparing thirty air-conditioned (AC) (n = 15) and naturally ventilated (NV) (n = 15) classrooms. The parameters of interest were indoor carbon dioxide (CO2), temperature, relative humidity (RH), wind speed, viable mold, and airborne dust levels. The NV rooms had larger concentration of mold than the AC rooms (1001.30 ± 125.16 and 367.00 ± 88.13 cfu/m3, respectively). The average indoor airborne dust concentration exceeded the Brazilian standards (<80 μg/m3) in both NV and AC classrooms. The levels of CO2 in the AC rooms were significantly different from the NV rooms (1433.62 ± 252.80 and 520.12 ± 37.25 ppm, respectively). The indoor air quality in Brazilian university classrooms affects the health of students. Therefore, indoor air pollution needs to be considered as an important public health problem. PMID:25019268

  13. MODELING INDOOR CONCENTRATIONS AND EXPOSURE

    EPA Science Inventory

    The paper discusses the use of an indoor air quality model, EXPOSURE, to predict pollutant concentrations and exposures. The effects of indoor air pollutants depend on the concentrations of the pollutants and the exposure of individuals to the pollutants. The air pollutant concen...

  14. Indoor air quality: A psychosocial perspective

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boxer, P.A.

    1990-05-01

    The incidence of indoor air quality problems has increased dramatically over the past decade. Investigation of these problems has yielded a definitive cause in only one third of the cases. Psychosocial factors may play a key role in the development and propagation of symptoms attributed to poor indoor air quality. Guidelines for managing indoor air quality problems from the organizational perspective are based upon psychosocial principles and elements of risk perception.

  15. Location detection and tracking of moving targets by a 2D IR-UWB radar system.

    PubMed

    Nguyen, Van-Han; Pyun, Jae-Young

    2015-03-19

    In indoor environments, the Global Positioning System (GPS) and long-range tracking radar systems are not optimal, because of signal propagation limitations in the indoor environment. In recent years, the use of ultra-wide band (UWB) technology has become a possible solution for object detection, localization and tracking in indoor environments, because of its high range resolution, compact size and low cost. This paper presents improved target detection and tracking techniques for moving objects with impulse-radio UWB (IR-UWB) radar in a short-range indoor area. This is achieved through signal-processing steps, such as clutter reduction, target detection, target localization and tracking. In this paper, we introduce a new combination consisting of our proposed signal-processing procedures. In the clutter-reduction step, a filtering method that uses a Kalman filter (KF) is proposed. Then, in the target detection step, a modification of the conventional CLEAN algorithm which is used to estimate the impulse response from observation region is applied for the advanced elimination of false alarms. Then, the output is fed into the target localization and tracking step, in which the target location and trajectory are determined and tracked by using unscented KF in two-dimensional coordinates. In each step, the proposed methods are compared to conventional methods to demonstrate the differences in performance. The experiments are carried out using actual IR-UWB radar under different scenarios. The results verify that the proposed methods can improve the probability and efficiency of target detection and tracking.

  16. Socio-economic inequity in demand for insecticide-treated nets, in-door residual house spraying, larviciding and fogging in Sudan

    PubMed Central

    Onwujekwe, Obinna; Malik, El-Fatih Mohamed; Mustafa, Sara Hassan; Mnzava, Abraham

    2005-01-01

    Background In order to optimally prioritize and use public and private budgets for equitable malaria vector control, there is a need to determine the level and determinants of consumer demand for different vector control tools. Objectives To determine the demand from people of different socio-economic groups for indoor residual house-spraying (IRHS), insecticide-treated nets (ITNs), larviciding with chemicals (LWC), and space spraying/fogging (SS) and the disease control implications of the result. Methods Ratings and levels of willingness-to-pay (WTP) for the vector control tools were determined using a random cross-sectional sample of 720 householdes drawn from two states. WTP was elicited using the bidding game. An asset-based socio-economic status (SES) index was used to explore whether WTP was related to SES of the respondents. Results IRHS received the highest proportion of highest preferred rating (41.0%) followed by ITNs (23.1%). However, ITNs had the highest mean WTP followed by IRHS, while LWC had the least. The regression analysis showed that SES was positively and statistically significantly related to WTP across the four vector control tools and that the respondents' rating of IRHS and ITNs significantly explained their levels of WTP for the two tools. Conclusion People were willing to pay for all the vector-control tools, but the demand for the vector control tools was related to the SES of the respondents. Hence, it is vital that there are public policies and financing mechanisms to ensure equitable provision and utilisation of vector control tools, as well as protecting the poor from cost-sharing arrangements. PMID:16356177

  17. 9 CFR 3.76 - Indoor housing facilities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Indoor housing facilities. 3.76... Transportation of Nonhuman Primates 2 Facilities and Operating Standards § 3.76 Indoor housing facilities. (a) Heating, cooling, and temperature. Indoor housing facilities must be sufficiently heated and cooled when...

  18. Calculating Least Risk Paths in 3d Indoor Space

    NASA Astrophysics Data System (ADS)

    Vanclooster, A.; De Maeyer, Ph.; Fack, V.; Van de Weghe, N.

    2013-08-01

    Over the last couple of years, research on indoor environments has gained a fresh impetus; more specifically applications that support navigation and wayfinding have become one of the booming industries. Indoor navigation research currently covers the technological aspect of indoor positioning and the modelling of indoor space. The algorithmic development to support navigation has so far been left mostly untouched, as most applications mainly rely on adapting Dijkstra's shortest path algorithm to an indoor network. However, alternative algorithms for outdoor navigation have been proposed adding a more cognitive notion to the calculated paths and as such adhering to the natural wayfinding behaviour (e.g. simplest paths, least risk paths). These algorithms are currently restricted to outdoor applications. The need for indoor cognitive algorithms is highlighted by a more challenged navigation and orientation due to the specific indoor structure (e.g. fragmentation, less visibility, confined areas…). As such, the clarity and easiness of route instructions is of paramount importance when distributing indoor routes. A shortest or fastest path indoors not necessarily aligns with the cognitive mapping of the building. Therefore, the aim of this research is to extend those richer cognitive algorithms to three-dimensional indoor environments. More specifically for this paper, we will focus on the application of the least risk path algorithm of Grum (2005) to an indoor space. The algorithm as proposed by Grum (2005) is duplicated and tested in a complex multi-storey building. The results of several least risk path calculations are compared to the shortest paths in indoor environments in terms of total length, improvement in route description complexity and number of turns. Several scenarios are tested in this comparison: paths covering a single floor, paths crossing several building wings and/or floors. Adjustments to the algorithm are proposed to be more aligned to the

  19. Indoor environment program. 1994 annual report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daisey, J.M.

    1995-04-01

    Buildings use approximately one-third of the energy consumed in the United States. The potential energy savings derived from reduced infiltration and ventilation in buildings are substantial, since energy use associated with conditioning and distributing ventilation air is about 5.5 EJ per year. However, since ventilation is the dominant mechanism for removing pollutants from indoor sources, reduction of ventilation can have adverse effects on indoor air quality, and on the health, comfort, and productivity of building occupants. The Indoor Environment Program in LBL`s Energy and Environment Division was established in 1977 to conduct integrated research on ventilation, indoor air quality, andmore » energy use and efficiency in buildings for the purpose of reducing energy liabilities associated with airflows into, within, and out of buildings while maintaining or improving occupant health and comfort. The Program is part of LBL`s Center for Building Science. Research is conducted on building energy use and efficiency, ventilation and infiltration, and thermal distribution systems; on the nature, sources, transport, transformation, and deposition of indoor air pollutants; and on exposure and health risks associated with indoor air pollutants. Pollutants of particular interest include radon; volatile, semivolatile, and particulate organic compounds; and combustion emissions, including environmental tobacco smoke, CO, and NO{sub x}.« less

  20. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF DISLODGEABLE RESIDUES -- PUF ROLLER SAMPLES FOR PERSISTENT ORGANIC POLLUTANTS (SOP-2.18)

    EPA Science Inventory

    This SOP describes the method to collect transferable residues from indoor floor surfaces. The sampling procedures described are applicable to bare floors or covered floor surfaces, e.g., carpeting and vinyl flooring. The samples will be collected only in the day care centers o...

  1. USE OF REAL-TIME LIGHT SCATTERING DATA TO ESTIMATE THE CONTRIBUTION OF INFILTRATED AND INDOOR-GENERATED PARTICLES TO INDOOR AIR

    EPA Science Inventory

    The contribution of outdoor particulate matter (PM) to residential indoor concentrations is currently not well understood. Most importantly, separating indoor PM into indoor- and outdoor-generated components will greatly enhance our knowledge of the outdoor contribution to tot...

  2. Psychosocial dimensions of solving an indoor air problem.

    PubMed

    Lahtinen, Marjaana; Huuhtanen, Pekka; Kähkönen, Erkki; Reijula, Kari

    2002-03-01

    This investigation focuses on the psychological and social dimensions of managing and solving indoor air problems. The data were collected in nine workplaces by interviews (n = 85) and questionnaires (n = 375). Indoor air problems in office environments have traditionally utilized industrial hygiene or technical expertise. However, indoor air problems at workplaces are often more complex issues to solve. Technical questions are inter-related with the dynamics of the work community, and the cooperation and interaction skills of the parties involved in the solving process are also put to the test. In the present study, the interviewees were very critical of the process of solving the indoor air problem. The responsibility for coordinating the problem-managing process was generally considered vague, as were the roles and functions of the various parties. Communication problems occurred and rumors about the indoor air problem circulated widely. Conflicts were common, complicating the process in several ways. The research focused on examining different ways of managing and resolving an indoor air problem. In addition, reference material on the causal factors of the indoor air problem was also acquired. The study supported the hypothesis that psychosocial factors play a significant role in indoor air problems.

  3. Accuracy and impact of spatial aids based upon satellite enumeration to improve indoor residual spraying spatial coverage.

    PubMed

    Bridges, Daniel J; Pollard, Derek; Winters, Anna M; Winters, Benjamin; Sikaala, Chadwick; Renn, Silvia; Larsen, David A

    2018-02-23

    Indoor residual spraying (IRS) is a key tool in the fight to control, eliminate and ultimately eradicate malaria. IRS protection is based on a communal effect such that an individual's protection primarily relies on the community-level coverage of IRS with limited protection being provided by household-level coverage. To ensure a communal effect is achieved through IRS, achieving high and uniform community-level coverage should be the ultimate priority of an IRS campaign. Ensuring high community-level coverage of IRS in malaria-endemic areas is challenging given the lack of information available about both the location and number of households needing IRS in any given area. A process termed 'mSpray' has been developed and implemented and involves use of satellite imagery for enumeration for planning IRS and a mobile application to guide IRS implementation. This study assessed (1) the accuracy of the satellite enumeration and (2) how various degrees of spatial aid provided through the mSpray process affected community-level IRS coverage during the 2015 spray campaign in Zambia. A 2-stage sampling process was applied to assess accuracy of satellite enumeration to determine number and location of sprayable structures. Results indicated an overall sensitivity of 94% for satellite enumeration compared to finding structures on the ground. After adjusting for structure size, roof, and wall type, households in Nchelenge District where all types of satellite-based spatial aids (paper-based maps plus use of the mobile mSpray application) were used were more likely to have received IRS than Kasama district where maps used were not based on satellite enumeration. The probability of a household being sprayed in Nchelenge district where tablet-based maps were used, did not differ statistically from that of a household in Samfya District, where detailed paper-based spatial aids based on satellite enumeration were provided. IRS coverage from the 2015 spray season benefited from

  4. Vortex-homogenized matrix solid-phase dispersion for the extraction of short chain chlorinated paraffins from indoor dust samples.

    PubMed

    Chen, Yu-Hsuan; Chang, Chia-Yu; Ding, Wang-Hsien

    2016-11-11

    A simple and effective method for determining short chain chlorinated paraffins (SCCPs) in indoor dust is presented. The method employed a modified vortex-homogenized matrix solid-phase dispersion (VH-MSPD) prior to its detection by gas chromatography - electron-capture negative-ion mass spectrometry (GC-ECNI-MS) operating in the selected-ion-monitoring (SIM) mode. Under the best extraction conditions, 0.1-g of dust sample was dispersed with 0.1-g of silica gel by using vortex (2min) instead of using a mortar and pestle (3min). After that step, the blend was transferred to a glass column containing 3-g acidic silica gel, 2-g basic silica gel, and 2-g of deactivated silica gel, used as clean-up co-sorbents. Then, target analytes were eluted with 5mL of n-hexane/dichloromethane (2:1, v/v) mixture. The extract was evaporated to dryness under a gentle stream of nitrogen. The residue was then re-dissolved in n-hexane (10μL), and subjected to GC-ECNI-MS analysis. The limits of quantitation (LOQs) ranged from 0.06 to 0.25μg/g for each SCCP congener. Precision was less than 7% for both intra- and inter-day analysis. Trueness was above 89%, which was calculated by mean extraction recovery. The VH-MSPD combined with GC-ECNI-MS was successfully applied to quantitatively detect SCCPs from various indoor dust samples, and the concentrations ranged from 1.2 to 31.2μg/g. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Importance of indoor dust biological ultrafine particles in the pathogenesis of chronic inflammatory lung diseases.

    PubMed

    Yang, Jinho; Kim, Yoon-Keun; Kang, Tae Soo; Jee, Young-Koo; Kim, You-Young

    2017-01-01

    The role of infectious agents in the etiology of inflammatory diseases once believed to be non-infectious is increasingly being recognized. Many bacterial components in the indoor dust can evoke inflammatory lung diseases. Bacteria secrete nanometer-sized vesicles into the extracellular milieu, so-called extracellular vesicles (EV). which are pathophysiologically related to inflammatory diseases. Microbiota compositions in the indoor dust revealed the presence of both Gram-negative and Gram-positive bacteria. Escherichia coli is a model organism of Gram-negative Enterobacteriaceae. The repeated inhalation of E. coli-derived EVs caused neutrophilic inflammation and emphysema in a dose-dependent manner. The emphysema induced by E. coli-derived EVs was partially eliminated by the absence of Interferon-gamma or interleukin-17, suggesting that Th1 and/or Th17 cell responses are important in the emphysema development. Meanwhile, the repeated inhalation of Staphylococcus aureus-derived EVs did not induce emphysema, although they induced neutrophilic inflammation in the lung. In terms of microbial EV compositions in the indoor dust, genera Pseudomonas, Acinetobacter, Enterobacter, and Staphylococcus were dominant. As for the clinical significance of sensitization to EVs in the indoor dust, EV sensitization was closely associated with asthma, chronic obstructive pulmonary disorder (COPD), and lung cancer. These data indicate that biological ultrafine particles in the indoor dust, which are mainly composed of microbial EVs, are important in the pathogenesis of chronic lung diseases associated with neutrophilic inflammation. Taken together, microbial EVs in the indoor dust are an important diagnostic and therapeutic target for the control of chronic lung diseases, such as asthma, COPD, and lung cancer.

  6. LADM and IndoorGML for Support of Indoor Space Identification

    NASA Astrophysics Data System (ADS)

    Zlatanova, S.; Van Oosterom, P. J. M.; Lee, J.; Li, K.-J.; Lemmen, C. H. J.

    2016-10-01

    Guidance and security in large public buildings such as airports, museums and shopping malls requires much more information that traditional 2D methods offer. Therefore 3D semantically-reach models have been actively investigated with the aim to gather knowledge about availability and accessibility of spaces. Spaces can be unavailable to specific users because of plenty of reasons: the 3D geometry of spaces (too low, too narrow), the properties of the objects to be guided to a specific part of the building (walking, driving, flying), the status of the indoor environment (e.g. crowded, limited light, under reconstruction), property regulations (private areas), security considerations and so on. However, such information is not explicitly avaible in the existing 3D semantically-reach models. IFC and CityGML are restricted to architectural building components and provide little to no means to describe such properties. IndoorGML has been designed to establish a generic approach for space identification allowing a space subdivision and automatic creation of a network for route computation. But currently it also represents only spaces as they are defined by the architectural layout of the building. The Land Administration Domain Model is currently the only available model to specify spaces on the basis of ownership and rights for use. In this paper we compare the principles of IndoorGML and LADM, investigate the approaches to define spaces and suggest options to the linking of the two types of spaces. We argue that LADM space subdivision on basis of properties and rights of use can be used to define to semantically and geometrically available and accessible spaces and therefore can enrich the IndoorGML concept.

  7. Indoor Air Quality and Ice Arenas

    EPA Pesticide Factsheets

    All recreational facilities including ice arenas should use good ventilation practices especially where children are present. It is critical that indoor air quality is protected particularly when using fuel-burning equipment indoors.

  8. Integrated Management of Residential Indoor Air Quality: A Call for Stakeholders in a Changing Climate.

    PubMed

    Levasseur, Marie-Eve; Poulin, Patrick; Campagna, Céline; Leclerc, Jean-Marc

    2017-11-25

    A paradigm change in the management of environmental health issues has been observed in recent years: instead of managing specific risks individually, a holistic vision of environmental problems would assure sustainable solutions. However, concrete actions that could help translate these recommendations into interventions are lacking. This review presents the relevance of using an integrated indoor air quality management approach to ensure occupant health and comfort. At the nexus of three basic concepts (reducing contaminants at the source, improving ventilation, and, when relevant, purifying the indoor air), this approach can help maintain and improve indoor air quality and limit exposure to several contaminants. Its application is particularly relevant in a climate change context since the evolving outdoor conditions have to be taken into account during building construction and renovation. The measures presented through this approach target public health players, building managers, owners, occupants, and professionals involved in building design, construction, renovation, and maintenance. The findings of this review will help the various stakeholders initiate a strategic reflection on the importance of indoor air quality and climate change issues for existing and future buildings. Several new avenues and recommendations are presented to set the path for future research activities.

  9. Integrated Management of Residential Indoor Air Quality: A Call for Stakeholders in a Changing Climate

    PubMed Central

    Levasseur, Marie-Eve; Poulin, Patrick; Campagna, Céline; Leclerc, Jean-Marc

    2017-01-01

    A paradigm change in the management of environmental health issues has been observed in recent years: instead of managing specific risks individually, a holistic vision of environmental problems would assure sustainable solutions. However, concrete actions that could help translate these recommendations into interventions are lacking. This review presents the relevance of using an integrated indoor air quality management approach to ensure occupant health and comfort. At the nexus of three basic concepts (reducing contaminants at the source, improving ventilation, and, when relevant, purifying the indoor air), this approach can help maintain and improve indoor air quality and limit exposure to several contaminants. Its application is particularly relevant in a climate change context since the evolving outdoor conditions have to be taken into account during building construction and renovation. The measures presented through this approach target public health players, building managers, owners, occupants, and professionals involved in building design, construction, renovation, and maintenance. The findings of this review will help the various stakeholders initiate a strategic reflection on the importance of indoor air quality and climate change issues for existing and future buildings. Several new avenues and recommendations are presented to set the path for future research activities. PMID:29186831

  10. School policies and practices that improve indoor air quality.

    PubMed

    Everett Jones, Sherry; Smith, Alisa M; Wheeler, Lani S; McManus, Tim

    2010-06-01

    To determine whether schools with a formal indoor air quality management program were more likely than schools without a formal program to have policies and practices that promote superior indoor air quality. This study analyzed school-level data from the 2006 School Health Policies and Programs Study, a national study of school health programs and policies at the state, district, and school levels. Using chi-square analyses, the rates of policies and practices that promote indoor air quality were compared between schools with and schools without a formal indoor air quality program. The findings of this study show that 51.4% of schools had a formal indoor air quality management program, and that those schools were significantly more likely than were schools without a program to have policies and use strategies to promote superior indoor air quality. These findings suggest that schools with a formal indoor air quality program are more likely support policies and engage in practices that promote superior indoor air quality.

  11. Indoor airPLUS Videos, Podcasts, Webinars and Interviews

    EPA Pesticide Factsheets

    The Webinar presentations will help you discover how Indoor airPLUS homes are designed to improve indoor air quality and increase energy efficiency and learn about the key design and construction features included in Indoor airPLUS homes.

  12. Teachers and Healthy Indoor School Environments

    EPA Pesticide Factsheets

    Teachers can be powerful advocates for creating healthy indoor environments, including improving school indoor air quality (IAQ). As they are on the front lines, teachers can perceive when IAQ changes affect students and themselves.

  13. Fungal pollution of indoor environments and its management.

    PubMed

    Haleem Khan, A A; Mohan Karuppayil, S

    2012-10-01

    Indoor environments play important roles in human health. The health hazards posed by polluted indoor environments include allergy, infections and toxicity. Life style changes have resulted in a shift from open air environments to air tight, energy efficient, environments, in which people spend a substantial portion of their time. Most indoor air pollution comes from the hazardous non biological agents and biological agents. Fungi are ubiquitous in distribution and are a serious threat to public health in indoor environments. In this communication, we have reviewed the current status on biotic indoor air pollution, role of fungi as biological contaminants and their impact on human health.

  14. Fungal pollution of indoor environments and its management

    PubMed Central

    Haleem Khan, A.A.; Mohan Karuppayil, S.

    2012-01-01

    Indoor environments play important roles in human health. The health hazards posed by polluted indoor environments include allergy, infections and toxicity. Life style changes have resulted in a shift from open air environments to air tight, energy efficient, environments, in which people spend a substantial portion of their time. Most indoor air pollution comes from the hazardous non biological agents and biological agents. Fungi are ubiquitous in distribution and are a serious threat to public health in indoor environments. In this communication, we have reviewed the current status on biotic indoor air pollution, role of fungi as biological contaminants and their impact on human health. PMID:23961203

  15. Air Quality and Indoor Environmental Exposures: Clinical ...

    EPA Pesticide Factsheets

    Indoor air quality (IAQ) is a term which refers to the air quality within and around buildings and homes as it relates to the health and comfort of the occupants. Many ambient (outdoor) air pollutants readily permeate indoor spaces. Because indoor air can be considerably more polluted than ambient air, the USEPA lists poor IAQ as a major environmental concern. In the sections that follow, health effects associated with commonly encountered ambient air pollutants and indoor contaminants will be broken down by agent class. In some cases, exposure may be acute, with one or more pets (and owners) experiencing signs within a relatively short period. However, most exposures are episodic or chronic, making it difficult to definitively link poor IAQ to respiratory or other adverse health outcomes. Age or underlying immunologic, cardiac, or respiratory disease may further complicate the clinical picture, as those patients may be more sensitive to (and affected by) lower concentrations than prove problematic for healthy housemates. Because pets, like their owners, spend most of their lives indoors, we will discuss how certain home conditions can worsen indoor air quality and will briefly discuss measures to improve IAQ for owners and their pets. In this overview presentation, health effects associated with commonly encountered ambient air pollutants and indoor contaminants will be broken down by agent class. Because pets, like their owners, spend most of their lives indoo

  16. Indoor airPLUS Web Linking Guidelines

    EPA Pesticide Factsheets

    As an Indoor airPLUS partner, your organization is listed on the EPA Indoor airPLUS Partner List. Your listing can also include a link to your organization's website when you meet the following requirements.

  17. Asthma randomized trial of indoor wood smoke (ARTIS): Rationale and Methods

    PubMed Central

    Noonan, Curtis W.; Ward, Tony J.

    2012-01-01

    Background Particulate matter (PM) exposures have been linked with poor respiratory health outcomes, especially among susceptible populations such as asthmatic children. Smoke from biomass combustion for residential home heating is an important source of PM in many rural or peri-urban areas in the United States. Aim To assess the efficacy of residential interventions that reduce indoor PM exposure from wood stoves and to quantify the corresponding improvements in quality of life and health outcomes for asthmatic children. Design The Asthma Randomized Trial of Indoor wood Smoke (ARTIS) study is an in-home intervention study of susceptible children exposed to biomass combustion smoke. Children, ages 7 to 17, with persistent asthma and living in homes that heat with wood stoves were recruited for this three arm randomized placebo-controlled trial. Two household-level intervention strategies, wood stove replacement and air filters, were compared to a sham air filter placebo. Improvement in quality of life of asthmatic children was the primary outcomes. Secondary asthma-related health outcomes included peak expiratory flow (PEF) and forced expiratory volume in first second (FEV1), biomarkers in exhaled breath condensate, and frequency of asthma symptoms, medication usage, and healthcare utilization. Exposure outcomes included indoor and outdoor PM2.5 mass, particle counts of several size fractions, and carbon monoxide. Discussion To our knowledge, this was the first randomized trial in the US to utilize interventions targeting residential wood stoves to assess the impact on indoor PM and health outcomes in a susceptible population. Trial registration ClincialTrials.gov NCT00807183. PMID:22735495

  18. Development and validation of the Comprehensive Indoor Tanning Expectations Scale.

    PubMed

    Noar, Seth M; Myrick, Jessica Gall; Morales-Pico, Brenda; Thomas, Nancy E

    2014-05-01

    Strong links between indoor tanning behavior and skin cancer have been demonstrated across several studies. Understanding the complex belief systems that underlie indoor tanning in young women is a crucial first step in developing interventions to deter this behavior. To develop and validate a comprehensive, multidimensional, theory-based outcome expectations measure to advance an understanding of the sets of beliefs that underlie indoor tanning behavior among young women. Cross-sectional study comprising a web-based survey of 11 sororities at a large university in the southeastern United States. Study participants (n = 706) were aged 18 to 25 years; 45.3% had tanned indoors in their lifetime and 30.3% in the past year. Intention to tan indoors, frequency of indoor tanning behavior in the past year, and indoor tanner type (nontanner, former tanner, or current tanner). A comprehensive scale assessing indoor tanning outcome expectations was developed. In total, 6 positive outcome expectations factors and 5 negative outcome expectations factors were identified. These subscales were reliable (coefficient α range, 0.86-0.95) and were significantly (mostly at P < .001) correlated with a set of established measures, including appearance motivation, indoor tanning attitudes and norms, and intention to tan indoors. Examination of subscales across the 3 indoor tanning groups also revealed significant (P < .001) differences on all 11 subscales. Current tanners had the most positive and least negative perceptions about indoor tanning, while nontanners had the most negative and least positive perceptions. Former tanners tended to fall in between these 2 groups. The 2 subscales with the largest differences across the groups were mood enhancement (positive outcome expectation) and psychological/physical discomfort (negative outcome expectation). Multiple linear regression analyses demonstrated several outcome expectations subscales to be significantly associated with

  19. A novel wireless local positioning system for airport (indoor) security

    NASA Astrophysics Data System (ADS)

    Zekavat, Seyed A.; Tong, Hui; Tan, Jindong

    2004-09-01

    A novel wireless local positioning system (WLPS) for airport (or indoor) security is introduced. This system is used by airport (indoor) security guards to locate all of, or a group of airport employees or passengers within the airport area. WLPS consists of two main parts: (1) a base station that is carried by security personnel; hence, introducing dynamic base station (DBS), and (2) a transponder (TRX) that is mounted on all people (including security personnel) present at the airport; thus, introducing them as active targets. In this paper, we (a) draw a futuristic view of the airport security systems, and the flow of information at the airports, (b) investigate the techniques of extending WLPS coverage area beyond the line-of-sight (LoS), and (c) study the performance of this system via standard transceivers, and direct sequence code division multiple access (DS-CDMA) systems with and without antenna arrays and conventional beamforming (BF).

  20. Education and indoor smoking among parents who smoke: the mediating role of perceived social norms of smoking.

    PubMed

    Saito, Junko; Shibanuma, Akira; Yasuoka, Junko; Kondo, Naoki; Takagi, Daisuke; Jimba, Masamine

    2018-02-02

    Parents with less formal education are more likely to smoke indoors, causing socioeconomic disparity in children's exposure to second-hand smoke. However, little is known about the roles of social factors in the socioeconomic gradients of indoor smoking. We tested the potential mediating role of perceived smoking norms on the associations between education and indoor smoking among parents who smoke. In this cross-sectional study, 822 smoking fathers and 823 smoking mothers, who lived with young children and were members of a Japanese online survey panel, participated. Structural equation modelling tested the mediating effects of perceived descriptive and subjective norms on the association between education and indoor smoking. Perceived pro-smoking norms, which were more prevalent among less-educated parents, mediated the association between education and indoor smoking. Household smoking status and worksite smoking ban also mediated this association via perceived norms, but only for fathers. Perceived descriptive norms explained 28.5% of the association for fathers and 37.6% for mothers; the corresponding percentages for perceived subjective norms were 9.8% and 26.6%, respectively. Perceived smoking norms, household smoking status, and a worksite smoking ban could be vital targets of a strategy aimed at reducing the socioeconomic disparity in parental home smoking behaviours.

  1. Preventing Skin Cancer Through Reduction of Indoor Tanning

    PubMed Central

    Watson, Meg; Holman, Dawn M.; Fox, Kathleen A.; Guy, Gery P.; Seidenberg, Andrew B.; Sampson, Blake P.; Sinclair, Craig; Lazovich, DeAnn

    2015-01-01

    Exposure to ultraviolet radiation from indoor tanning devices (tanning beds, booths, and sun lamps) or from the sun contributes to the risk of skin cancer, including melanoma, which is the type of skin cancer responsible for most deaths. Indoor tanning is common among certain groups, especially among older adolescents and young adults, adolescent girls and young women, and non-Hispanic whites. Increased understanding of the health risks associated with indoor tanning has led to many efforts to reduce use. Most environmental and systems efforts in the U.S. (e.g., age limits or requiring parental consent/accompaniment) have occurred at the state level. At the national level, the U.S. Food and Drug Administration and the Federal Trade Commission regulate indoor tanning devices and advertising, respectively. The current paper provides a brief review of (1) the evidence on indoor tanning as a risk factor for skin cancer; (2) factors that may influence use of indoor tanning devices at the population level; and (3) various environmental and systems options available for consideration when developing strategies to reduce indoor tanning. This information provides the context and background for the companion paper in this issue of the American Journal of Preventive Medicine, which summarizes highlights from an informal expert meeting convened by the CDC in August 2012 to identify opportunities to prevent skin cancer by reducing use of indoor tanning devices. PMID:23683987

  2. Effects of Indoor Air Pollutants on Atopic Dermatitis.

    PubMed

    Kim, JaKyoung; Kim, HyungJin; Lim, DaeHyun; Lee, Young-Kyu; Kim, Jeong Hee

    2016-12-09

    The increasing prevalence of atopic dermatitis (AD) is associated with variations in indoor environments. In Korea, many inner walls of homes are covered with wallpaper: such walls emit indoor air pollutants, including volatile organic compounds (VOCs) and formaldehyde. This randomized, double-blind study investigated the effects of wallpaper on indoor air quality and AD. Thirty-one children (aged three to eight years) with moderate AD were assigned to environmentally-friendly (EF) and polyvinyl chloride (PVC) wallpaper groups. Indoor air concentrations of VOCs, natural VOCs (NVOCs), formaldehyde, and total suspended bacteria were measured before and two (W₂) and eight weeks (W₈) after wallpapering. Scoring Atopic Dermatitis (SCORAD) evaluations and blood tests were performed during the same period. The EF wallpaper and PVC wallpaper groups showed similar trends in the changes in total VOCs (TVOC) and formaldehyde content in the indoor air. However, the EF wallpaper group showed more improvement on the SCORAD at W₂ and W₈ than the PVC wallpaper group. The SCORAD index was positively correlated with several indoor air pollutants. Further, the SCORAD index and NVOC % were negatively correlated. Improved SCORAD index and effects of wallpapering on indoor air quality improvements occurred within a short period of time in both groups. We believe that NVOCs in indoor air after EF wallpapering have a beneficial effect on health.

  3. Effects of Indoor Air Pollutants on Atopic Dermatitis

    PubMed Central

    Kim, JaKyoung; Kim, HyungJin; Lim, DaeHyun; Lee, Young-Kyu; Kim, Jeong Hee

    2016-01-01

    The increasing prevalence of atopic dermatitis (AD) is associated with variations in indoor environments. In Korea, many inner walls of homes are covered with wallpaper: such walls emit indoor air pollutants, including volatile organic compounds (VOCs) and formaldehyde. This randomized, double-blind study investigated the effects of wallpaper on indoor air quality and AD. Thirty-one children (aged three to eight years) with moderate AD were assigned to environmentally-friendly (EF) and polyvinyl chloride (PVC) wallpaper groups. Indoor air concentrations of VOCs, natural VOCs (NVOCs), formaldehyde, and total suspended bacteria were measured before and two (W2) and eight weeks (W8) after wallpapering. Scoring Atopic Dermatitis (SCORAD) evaluations and blood tests were performed during the same period. The EF wallpaper and PVC wallpaper groups showed similar trends in the changes in total VOCs (TVOC) and formaldehyde content in the indoor air. However, the EF wallpaper group showed more improvement on the SCORAD at W2 and W8 than the PVC wallpaper group. The SCORAD index was positively correlated with several indoor air pollutants. Further, the SCORAD index and NVOC % were negatively correlated. Improved SCORAD index and effects of wallpapering on indoor air quality improvements occurred within a short period of time in both groups. We believe that NVOCs in indoor air after EF wallpapering have a beneficial effect on health. PMID:27941696

  4. Contribution of the residue at position 4 within classical nuclear localization signals to modulating interaction with importins and nuclear targeting.

    PubMed

    Smith, Kate M; Di Antonio, Veronica; Bellucci, Luca; Thomas, David R; Caporuscio, Fabiana; Ciccarese, Francesco; Ghassabian, Hanieh; Wagstaff, Kylie M; Forwood, Jade K; Jans, David A; Palù, Giorgio; Alvisi, Gualtiero

    2018-08-01

    Nuclear import involves the recognition by importin (IMP) superfamily members of nuclear localization signals (NLSs) within protein cargoes destined for the nucleus, the best understood being recognition of classical NLSs (cNLSs) by the IMPα/β1 heterodimer. Although the cNLS consensus [K-(K/R)-X-(K/R) for positions P2-P5] is generally accepted, recent studies indicated that the contribution made by different residues at the P4 position can vary. Here, we apply a combination of microscopy, molecular dynamics, crystallography, in vitro binding, and bioinformatics approaches to show that the nature of residues at P4 indeed modulates cNLS function in the context of a prototypical Simian Virus 40 large tumor antigen-derived cNLS (KKRK, P2-5). Indeed, all hydrophobic substitutions in place of R impaired binding to IMPα and nuclear targeting, with the largest effect exerted by a G residue at P4. Substitution of R with neutral hydrophobic residues caused the loss of electrostatic and van der Waals interactions between the P4 residue side chains and IMPα. Detailed bioinformatics analysis confirmed the importance of the P4 residue for cNLS function across the human proteome, with specific residues such as G being associated with low activity. Furthermore, we validate our findings for two additional cNLSs from human cytomegalovirus (HCMV) DNA polymerase catalytic subunit UL54 and processivity factor UL44, where a G residue at P4 results in a 2-3-fold decrease in NLS activity. Our results thus showed that the P4 residue makes a hitherto poorly appreciated contribution to nuclear import efficiency, which is essential to determining the precise nuclear levels of cargoes. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Indoor radon survey in Visegrad countries.

    PubMed

    Műllerová, Monika; Kozak, Krzysztof; Kovács, Tibor; Smetanová, Iveta; Csordás, Anita; Grzadziel, Dominik; Holý, Karol; Mazur, Jadwiga; Moravcsík, Attila; Neznal, Martin; Neznal, Matej

    2016-04-01

    The indoor radon measurements were carried out in 123 residential buildings and 33 schools in Visegrad countries (Slovakia, Hungary and Poland). In 13.2% of rooms radon concentration exceeded 300Bqm(-3), the reference value recommended in the Council Directive 2013/59/EURATOM. Indoor radon in houses shows the typical radon behavior, with a minimum in the summer and a maximum in the winter season, whereas in 32% of schools the maximum indoor radon was reached in the summer months. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Become an Indoor airPLUS Verifier

    EPA Pesticide Factsheets

    With the Indoor airPLUS Program, 3rd-party verifiers help ensure that EPA's high standards, based on leading building science, are applied by the builder during home design and construction to meet the Indoor airPLUS Construction Specifications.

  7. The use of pesticides in Belgian illicit indoor cannabis plantations.

    PubMed

    Cuypers, Eva; Vanhove, Wouter; Gotink, Joachim; Bonneure, Arne; Van Damme, Patrick; Tytgat, Jan

    2017-08-01

    Cannabis (Cannabis spp.) use and cultivation continue to increase in many (European) countries. The illicit indoor cannabis plantations that supply Belgian and European cannabis markets create problems and concerns about health and safety of intervention staff, dismantling companies, the direct environment of cannabis plantations and, eventually, of cannabis users. Main risks may come from pesticide residues on plants, cultivation infrastructure and materials; left-over plant growth-promoting substances; mycotoxins from fungal pathogens on harvested plants; and/or high levels of cannabinoids in cannabis plant parts for consumption. In the present research, we report on pesticides found in illicit indoor cannabis plantations in Belgium. EN15662 QuEChERS extraction method and LC-MS/MS analysis were used to identify pesticides in indoor cannabis plantations and thus to evaluate the hazards associated with the use, cultivation and removal of cannabis plants in plantations as well as with dismantling activities in the cultivation rooms. We found pesticides in 64.3% of 72 cannabis plant samples and in 65.2% of 46 carbon filter cloth samples. Overall, 19 pesticides belonging to different chemical classes were identified. We found o-phenylphenol, bifenazate, cypermethrin, imidacloprid, propamocarb, propiconazole and tebuconazole, which is consistent with the commonly reported pesticides from literature. In only a few cases, pesticides found in bottles with a commercial label, were also identified in plant or stagnant water samples collected from the growth rooms where the bottles had been collected. We further revealed that, even though most pesticides have a low volatility, they could be detected from the carbon filters hanging at the ceiling of cultivation rooms. As a result, it is likely that pesticides also prevail in the plantation atmosphere during and after cultivation. The risk of inhaling the latter pesticides increases when plants sprayed with pesticides are

  8. Air Quality and Indoor Environmental Exposures: Clinical Impacts

    EPA Science Inventory

    Indoor air quality (IAQ) is a term which refers to the air quality within and around buildings and homes as it relates to the health and comfort of the occupants. Many ambient (outdoor) air pollutants readily permeate indoor spaces. Because indoor air can be considerably more pol...

  9. EVALUATING SOURCES OF INDOOR AIR POLLUTION

    EPA Science Inventory

    The article discusses a three-phase approach, employing environmental chambers, indoor air quality (IAQ) models, and test house experiments, that is effective in linking sources of indoor pollutants to measured concentrations. mission factors developed in test chambers can be use...

  10. Importance of indoor dust biological ultrafine particles in the pathogenesis of chronic inflammatory lung diseases

    PubMed Central

    Kim, Yoon-Keun; Kang, Tae Soo; Kim, You-Young

    2017-01-01

    The role of infectious agents in the etiology of inflammatory diseases once believed to be non-infectious is increasingly being recognized. Many bacterial components in the indoor dust can evoke inflammatory lung diseases. Bacteria secrete nanometer-sized vesicles into the extracellular milieu, so-called extracellular vesicles (EV). which are pathophysiologically related to inflammatory diseases. Microbiota compositions in the indoor dust revealed the presence of both Gram-negative and Gram-positive bacteria. Escherichia coli is a model organism of Gram-negative Enterobacteriaceae. The repeated inhalation of E. coli-derived EVs caused neutrophilic inflammation and emphysema in a dose-dependent manner. The emphysema induced by E. coli-derived EVs was partially eliminated by the absence of Interferon-gamma or interleukin-17, suggesting that Th1 and/or Th17 cell responses are important in the emphysema development. Meanwhile, the repeated inhalation of Staphylococcus aureus-derived EVs did not induce emphysema, although they induced neutrophilic inflammation in the lung. In terms of microbial EV compositions in the indoor dust, genera Pseudomonas, Acinetobacter, Enterobacter, and Staphylococcus were dominant. As for the clinical significance of sensitization to EVs in the indoor dust, EV sensitization was closely associated with asthma, chronic obstructive pulmonary disorder (COPD), and lung cancer. These data indicate that biological ultrafine particles in the indoor dust, which are mainly composed of microbial EVs, are important in the pathogenesis of chronic lung diseases associated with neutrophilic inflammation. Taken together, microbial EVs in the indoor dust are an important diagnostic and therapeutic target for the control of chronic lung diseases, such as asthma, COPD, and lung cancer. PMID:29161804

  11. [Schools, office buildings, leisure settings: diversity of indoor air quality issues. Global review on indoor air quality in these settings].

    PubMed

    Mandin, C; Derbez, M; Kirchner, S

    2012-07-01

    This review provides a global overview of indoor air quality issues in schools, office buildings and recreational settings. It presents the most recent scientific publications and the on-going work conducted in France in the frame of the indoor air quality Observatory. Monitoring campaigns on indoor air quality in schools have been carried out in the recent years in Europe. However, few studies have specifically addressed the role of exposure in these buildings on children's health. Indoor air quality in office buildings has been little studied so far. However, some specificities, such as emissions from electronic devices, frequent cleaning, impossibility to open windows in high-rise buildings, for example, should be examined and their role on the health and comfort studied. Finally, even if the time spent in recreational settings is short, the quality of indoor air should also be considered because of specific pollution. This is the case of indoor swimming pools (exposure to chlorination byproducts) and ice-rinks (exposure to exhaust from machines used to smooth the ice). Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  12. Engaging Moms on Teen Indoor Tanning Through Social Media: Protocol of a Randomized Controlled Trial

    PubMed Central

    Baker, Katie; Griffith, Julia; Oleski, Jessica L; Palumbo, Ashley; Walkosz, Barbara J; Hillhouse, Joel; Henry, Kimberly L; Buller, David B

    2016-01-01

    Background Indoor tanning elevates the risk for melanoma, which is now the most common cancer in US women aged 25-29. Public policies restricting access to indoor tanning by minors to reduce melanoma morbidity and mortality in teens are emerging. In the United States, the most common policy restricting indoor tanning in minors involves parents providing either written or in person consent for the minor to purchase a tanning visit. The effectiveness of this policy relies on parents being properly educated about the harms of indoor tanning to their children. Objective This randomized controlled trial will test the efficacy of a Facebook-delivered health communication intervention targeting mothers of teenage girls. The intervention will use health communication and behavioral modification strategies to reduce mothers’ permissiveness regarding their teenage daughters’ use of indoor tanning relative to an attention-control condition with the ultimate goal of reducing indoor tanning in both daughters and mothers. Methods The study is a 12-month randomized controlled trial comparing 2 conditions: an attention control Facebook private group where content will be relevant to teen health with 25% focused on prescription drug abuse, a topic unrelated to tanning; and the intervention condition will enter participants into a Facebook private group where 25% of the teen health content will be focused on indoor tanning. A cohort of 2000 mother-teen daughter dyads will be recruited to participate in this study. Only mothers will participate in the Facebook groups. Both mothers and daughters will complete measures at baseline, end of intervention (1-year) and 6 months post-intervention. Primary outcomes include mothers’ permissiveness regarding their teenage daughters’ use of indoor tanning, teenage daughters’ perception of their mothers’ permissiveness, and indoor tanning by both mothers and daughters. Results The first dyad was enrolled on March 31, 2016, and we

  13. Usability analysis of indoor map application in a shopping centre

    NASA Astrophysics Data System (ADS)

    Dewi, R. S.; Hadi, R. K.

    2018-04-01

    Although indoor navigation is still new in Indonesia, its future development is very promising. Similar to the outdoor one, the indoor navigation technology provides several important functions to support route and landmark findings. Furthermore, there is also a need that indoor navigation can support the public safety especially during disaster evacuation process in a building. It is a common that the indoor navigation technologies are built as applications where users can access this technology using their smartphones, tablets, or personal computers. Therefore, a usability analysis is important to ensure the indoor navigation applications can be operated by users with highest functionality. Among several indoor map applications which were available in the market, this study chose to analyse indoor Google Maps due to its availability and popularity in Indonesia. The experiments to test indoor Google Maps was conducted in one of the biggest shopping centre building in Surabaya, Indonesia. The usability was measured by employing System Usability Scale (SUS) questionnaire. The result showed that the SUS score of indoor Google Maps was below the average score of other cellular applications to indicate the users still had high difficulty in operating and learning the features of indoor Google Maps.

  14. Indoor air pollution from biomass fuels and respiratory health of the exposed population in Nepalese households.

    PubMed

    Shrestha, Iswori Lal; Shrestha, Srijan Lal

    2005-01-01

    A cross-sectional assessment of indoor air quality in Nepal and its health effects revealed that solid biomass fuels (animal dung, crop residue, and wood) were the main sources of indoor air pollution affecting health. The average smoke level (PM10) in kitchens using biomass fuels was about three times higher than that in those using cleaner fuels (kerosene, LPG, and biogas). Respondents in 98 randomly selected households included 168 who cooked daily meals, of whom 94% were disadvantaged women. Biomass smoke caused significantly more respiratory disorders than did cleaner fuels. Categorized data analysis demonstrated significant associations between biomass smoke pollution and respiratory symptoms such as cough; phlegm; breathlessness; wheezing; and chronic respiratory diseases such as COPD and asthma. The prevalences of respiratory illnesses and symptoms were considerably higher in those living in mud and brick houses compared with concrete houses. Prevalences were also higher in those living on hills and in rural areas compared with flatland and urban areas.

  15. ENVIRONMENTAL TECHNOLOGY VERIFICATION AND INDOOR AIR

    EPA Science Inventory

    The paper discusses environmental technology verification and indoor air. RTI has responsibility for a pilot program for indoor air products as part of the U.S. EPA's Environmental Technology Verification (ETV) program. The program objective is to further the development of sel...

  16. TESTS OF INDOOR AIR QUALITY SINKS

    EPA Science Inventory

    Experiments were conducted in a room-size test chamber to determine the sink effects of selected materials on indoor air concentrations of p-dichlorobenzene (PDCB). hese effects might alter pollutant behavior from that predicted using similar indoor air quality models, by reducin...

  17. Climate change and health: Indoor heat exposure in vulnerable populations☆

    PubMed Central

    White-Newsome, Jalonne L.; Sánchez, Brisa N.; Jolliet, Olivier; Zhang, Zhenzhen; Parker, Edith A.; Dvonch, J. Timothy; O'Neill, Marie S.

    2015-01-01

    Introduction Climate change is increasing the frequency of heat waves and hot weather in many urban environments. Older people are more vulnerable to heat exposure but spend most of their time indoors. Few published studies have addressed indoor heat exposure in residences occupied by an elderly population. The purpose of this study is to explore the relationship between outdoor and indoor temperatures in homes occupied by the elderly and determine other predictors of indoor temperature. Materials and methods We collected hourly indoor temperature measurements of 30 different homes; outdoor temperature, dewpoint temperature, and solar radiation data during summer 2009 in Detroit, MI. We used mixed linear regression to model indoor temperatures’ responsiveness to weather, housing and environmental characteristics, and evaluated our ability to predict indoor heat exposures based on outdoor conditions. Results Average maximum indoor temperature for all locations was 34.85 °C, 13.8 °C higher than average maximum outdoor temperature. Indoor temperatures of single family homes constructed of vinyl paneling or wood siding were more sensitive than brick homes to outdoor temperature changes and internal heat gains. Outdoor temperature, solar radiation, and dewpoint temperature predicted 38% of the variability of indoor temperatures. Conclusions Indoor exposures to heat in Detroit exceed the comfort range among elderly occupants, and can be predicted using outdoor temperatures, characteristics of the housing stock and surroundings PMID:22071034

  18. Parent's Guide to School Indoor Air Quality. Revised

    ERIC Educational Resources Information Center

    Healthy Schools Network, Inc., 2012

    2012-01-01

    Air pollution is air pollution, indoors or out. Good indoor air quality (IAQ) contributes to a favorable learning environment for students, protects health, and supports the productivity of school personnel. In schools in poor repair, leaky roofs and crumbling walls have caused additional indoor air quality problems, including contamination with…

  19. Plils: A Practical Indoor Localization System through Less Expensive Wireless Chips via Subregion Clustering.

    PubMed

    Li, Xiaolong; Yang, Yifu; Cai, Jun; Deng, Yun; Yang, Junfeng; Zhou, Xinmin; Tan, Lina

    2018-01-12

    Reducing costs is a pragmatic method for promoting the widespread usage of indoor localization technology. Conventional indoor localization systems (ILSs) exploit relatively expensive wireless chips to measure received signal strength for positioning. Our work is based on a cheap and widely-used commercial off-the-shelf (COTS) wireless chip, i.e., the Nordic Semiconductor nRF24LE1, which has only several output power levels, and proposes a new power level based-ILS, called Plils. The localization procedure incorporates two phases: an offline training phase and an online localization phase. In the offline training phase, a self-organizing map (SOM) is utilized for dividing a target area into k subregions, wherein their grids in the same subregion have similar fingerprints. In the online localization phase, the support vector machine (SVM) and back propagation (BP) neural network methods are adopted to identify which subregion a tagged object is located in, and calculate its exact location, respectively. The reasonable value for k has been discussed as well. Our experiments show that Plils achieves 75 cm accuracy on average, and is robust to indoor obstacles.

  20. [Main indoor air pollutants and their health impacts].

    PubMed

    Xu, Zhen; Jin, Yinlong

    2003-05-01

    The quality of indoor air is a very important factor that may directly affect human health. There are many sources as well as a variety of indoor air pollutants. Therefore, the health impact is complicated, affecting different organs and systems of human being such as respiratory and immune system. The main indoor air pollutants are the combustion products from smoking, cooking and heating, the chemical pollutants from renovation materials and the biological contaminants. The kinds, sources and health impacts of these pollutants that affect the indoor air quality are reviewed in this paper.

  1. Indoor air quality in Latino homes in Boulder, Colorado

    NASA Astrophysics Data System (ADS)

    Escobedo, Luis E.; Champion, Wyatt M.; Li, Ning; Montoya, Lupita D.

    2014-08-01

    Indoor concentrations of airborne pollutants can be several times higher than those found outdoors, often due to poor ventilation, overcrowding, and the contribution of indoor sources within a home. Americans spend most of their time indoors where exposure to poor indoor air quality (IAQ) can result in diminished respiratory and cardiovascular health. This study measured the indoor air quality in 30 homes of a low-income Latino community in Boulder, Colorado during the summer of 2012. Participants were administered a survey, which included questions on their health conditions and indoor air pollution sources like cigarette smoke, heating fuel, and building materials. Twenty-four hour samples of fine particulate matter (PM2.5) from the indoor air were collected in each home; ambient PM2.5 samples were collected each day as well. Concurrent air samples were collected onto 47 mm Teflo and Tissuquartz filter at each location. Teflo filters were analyzed gravimetrically to measure PM2.5 and their extracts were used to determine levels of proteins and endotoxins in the fine fraction. The Tissuquartz filters were analyzed for elemental and organic carbon content (EC/OC). Results indicated that the indoor air contained higher concentrations of PM2.5 than the ambient air, and that the levels of OC were much higher than EC in both indoor and outdoor samples. This community showed no smoking in their homes and kept furry pets indoors at very low rates; therefore, cooking is likely the primary source of indoor PM. For responders with significant exposure to PM, it appeared to be primarily from occupational environments or childhood exposure abroad. Our findings indicate that for immigrant communities such as this, it is important to consider not only their housing conditions but also the relevant prior exposures when conducting health assessments.

  2. Association of Skin Cancer and Indoor Tanning in Sexual Minority Men and Women.

    PubMed

    Mansh, Matthew; Katz, Kenneth A; Linos, Eleni; Chren, Mary-Margaret; Arron, Sarah

    2015-12-01

    Skin cancer, the most common cancer in the United States, is highly associated with outdoor and indoor tanning behaviors. Although indoor tanning has been suggested to be more common among sexual minority (self-reported as homosexual, gay, or bisexual) men compared with heterosexual men, whether rates of skin cancer vary by sexual orientation is unknown. To investigate whether skin cancer prevalence and indoor tanning behaviors vary by sexual orientation in the general population. We performed a cross-sectional study using data from the 2001, 2003, 2005, and 2009 California Health Interview Surveys (CHISs) and the 2013 National Health Interview Survey (NHIS) of population-based samples of the California and US noninstitutionalized civilian population. Participants included 192 575 men and women 18 years or older who identified as heterosexual or a sexual minority. Self-reported lifetime history of skin cancer and 12-month history of indoor tanning. The study included 78 487 heterosexual men, 3083 sexual minority men, 107 976 heterosexual women, and 3029 sexual minority women. Sexual minority men were more likely than heterosexual men to report having skin cancer (2001-2005 CHISs: adjusted odds ratio [aOR], 1.56; 95% CI, 1.18-2.06, P < .001; 2013 NHIS: aOR, 2.13; 95% CI, 1.14-3.96, P = .02) and having tanned indoors (2009 CHIS: aOR, 5.80; 95% CI, 2.90-11.60, P < .001; 2013 NHIS: aOR, 3.16; 95% CI, 1.77-5.64, P < .001). Sexual minority women were less likely than heterosexual women to report having had nonmelanoma skin cancer (2001-2005 CHIS: aOR, 0.56; 95% CI, 0.37-0.86, P = .008) and having tanned indoors (2009 CHIS: aOR, 0.43; 95% CI, 0.20-0.92, P = .03; 2013 NHIS: aOR, 0.46; 95% CI, 0.26-0.81, P = .007). Sexual minority men indoor tan more frequently and report higher rates of skin cancer than heterosexual men. Primary and secondary prevention efforts targeted at sexual minority men might reduce risk factors for

  3. Vitality of plants to live in the indoor environment

    NASA Astrophysics Data System (ADS)

    Shamsuri, Mohd Mahathir Suhaimi; Leman, A. M.; Hariri, Azian; Idris, Ahmad Fu'ad; Afandi, Azizi

    2017-09-01

    Indoor air quality (IAQ) is generally a public concern because 90% of people spend their time indoor. IAQ must be preserved wisely to guarantee the health of the building occupants. One of the ways to maintain the quality of air is by placing plants in the building. However, all plants come from the outdoor, and the environment is different compared to indoor. Environmental factors such as temperature and light will absolutely affect the growth of the plant. Light and temperature that are too bright or too deem can wither the plants. Nevertheless, certain plant is capable of adapting with different situation after assimilation process has been conducted. This study intends to analyze the capacity of seven selected plants (Anthurium, Dumb Cane, Golden Pothos, Kadaka Fern, Prayer Plant, Spider Plant, and Syngonium) to live in an indoor environment. The vitality of plants is based on photosynthetic level that is measured using leaf - chamber (LI-COR 6400). Two groups of plants were located in indoor and outdoor (indigenous location) setting, and were allowed to assimilate for two months before measurement were carried out. The results for the plant located indoor shows that only Spider Plant cannot perform photosynthesis under 300 lux, where the photosynthetic value remains negative. Meanwhile, other plants such as Anthurium, Dumb Cane, Golden Pothos, Kadaka Fern, Prayer Plant, and Syngonium that were left indoor showed similar 300 lux in which conform the ability of the plants to perform photosynthesis with the value of 0.3, 0.15, 0.35, 0.1, 0.15, and 0.1. In comparison, all of the plants that were stationed indoor and outdoor (except Spider Plant), the light compensation point (LCP) for indoor shows smaller value than the outdoor. This is because all the indoor plants had down - regulated their photosynthesis process by becoming more sensitive to light after their assimilation. From this study, it can be concluded that all plants except Spider Plant is able to live

  4. Fully Distributed Monitoring Architecture Supporting Multiple Trackees and Trackers in Indoor Mobile Asset Management Application

    PubMed Central

    Jeong, Seol Young; Jo, Hyeong Gon; Kang, Soon Ju

    2014-01-01

    A tracking service like asset management is essential in a dynamic hospital environment consisting of numerous mobile assets (e.g., wheelchairs or infusion pumps) that are continuously relocated throughout a hospital. The tracking service is accomplished based on the key technologies of an indoor location-based service (LBS), such as locating and monitoring multiple mobile targets inside a building in real time. An indoor LBS such as a tracking service entails numerous resource lookups being requested concurrently and frequently from several locations, as well as a network infrastructure requiring support for high scalability in indoor environments. A traditional centralized architecture needs to maintain a geographic map of the entire building or complex in its central server, which can cause low scalability and traffic congestion. This paper presents a self-organizing and fully distributed indoor mobile asset management (MAM) platform, and proposes an architecture for multiple trackees (such as mobile assets) and trackers based on the proposed distributed platform in real time. In order to verify the suggested platform, scalability performance according to increases in the number of concurrent lookups was evaluated in a real test bed. Tracking latency and traffic load ratio in the proposed tracking architecture was also evaluated. PMID:24662407

  5. Fully distributed monitoring architecture supporting multiple trackees and trackers in indoor mobile asset management application.

    PubMed

    Jeong, Seol Young; Jo, Hyeong Gon; Kang, Soon Ju

    2014-03-21

    A tracking service like asset management is essential in a dynamic hospital environment consisting of numerous mobile assets (e.g., wheelchairs or infusion pumps) that are continuously relocated throughout a hospital. The tracking service is accomplished based on the key technologies of an indoor location-based service (LBS), such as locating and monitoring multiple mobile targets inside a building in real time. An indoor LBS such as a tracking service entails numerous resource lookups being requested concurrently and frequently from several locations, as well as a network infrastructure requiring support for high scalability in indoor environments. A traditional centralized architecture needs to maintain a geographic map of the entire building or complex in its central server, which can cause low scalability and traffic congestion. This paper presents a self-organizing and fully distributed indoor mobile asset management (MAM) platform, and proposes an architecture for multiple trackees (such as mobile assets) and trackers based on the proposed distributed platform in real time. In order to verify the suggested platform, scalability performance according to increases in the number of concurrent lookups was evaluated in a real test bed. Tracking latency and traffic load ratio in the proposed tracking architecture was also evaluated.

  6. Climate change and health: Indoor heat exposure in vulnerable populations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White-Newsome, Jalonne L., E-mail: jalonne@umich.edu; Sanchez, Brisa N., E-mail: brisa@umich.edu; Jolliet, Olivier, E-mail: ojolliet@umich.edu

    2012-01-15

    Introduction: Climate change is increasing the frequency of heat waves and hot weather in many urban environments. Older people are more vulnerable to heat exposure but spend most of their time indoors. Few published studies have addressed indoor heat exposure in residences occupied by an elderly population. The purpose of this study is to explore the relationship between outdoor and indoor temperatures in homes occupied by the elderly and determine other predictors of indoor temperature. Materials and methods: We collected hourly indoor temperature measurements of 30 different homes; outdoor temperature, dewpoint temperature, and solar radiation data during summer 2009 inmore » Detroit, MI. We used mixed linear regression to model indoor temperatures' responsiveness to weather, housing and environmental characteristics, and evaluated our ability to predict indoor heat exposures based on outdoor conditions. Results: Average maximum indoor temperature for all locations was 34.85 Degree-Sign C, 13.8 Degree-Sign C higher than average maximum outdoor temperature. Indoor temperatures of single family homes constructed of vinyl paneling or wood siding were more sensitive than brick homes to outdoor temperature changes and internal heat gains. Outdoor temperature, solar radiation, and dewpoint temperature predicted 38% of the variability of indoor temperatures. Conclusions: Indoor exposures to heat in Detroit exceed the comfort range among elderly occupants, and can be predicted using outdoor temperatures, characteristics of the housing stock and surroundings to improve heat exposure assessment for epidemiological investigations. Weatherizing homes and modifying home surroundings could mitigate indoor heat exposure among the elderly.« less

  7. Adverse health effects of indoor moulds.

    PubMed

    Piecková, Elena

    2012-12-01

    Building associated illnesses - sick building syndrome (SBS) as a common example - are associated with staying in buildings with poor indoor air quality. The importance of indoor fungal growth in this phenomenon continues to be evident, even though no causative relation has been established so far. Indoor humidity is strongly associated with the symptoms of SBS. Fungal metabolites that may induce ill health in susceptible occupants comprise beta-D-glucan, mycotoxins, and volatile organic compounds as known irritants and/or immunomodulators. Indoor toxic fungal metabolites might be located in micromycetal propagules (endometabolites), in (bio-)aerosol, detritus, and house dust (exometabolites) as their particular carriers. It is highly probable that hyphal fragments, dust, and particles able to reach the alveoli have the strongest depository and toxic potential. Most fungal spores are entrapped by the upper respiratory tract and do not reach further than the bronchi because of their size, morphology, and the mode of propagation (such as slime heads and aggreggation). This is why studies of the toxic effects of fungal spores prefer directly applying metabolite mixtures over mimicking real exposure. Chronic low-level exposure to a mixture of fungal toxicants and other indoor stressors may have synergistic effects and lead to severe neuroendocrineimmune changes.

  8. The hydroxyl radical (OH) in indoor air: Sources and implications

    NASA Astrophysics Data System (ADS)

    Gligorovski, Sasho; Wortham, Henri; Kleffmann, Jörg

    2014-12-01

    Considering that people spend on average 80-90% of their life indoors, indoor air quality is of major importance for human health. In addition to specific indoor sources and entrainment from the outside atmosphere, harmful pollutants can be also formed indoors by in-situ secondary chemistry. While the first two processes have been well studied in the past, our understanding of indoor oxidation processes is still in its infancy compared to the ambient atmosphere.

  9. Indoor Air Quality Science and Technology

    EPA Pesticide Factsheets

    Understand indoor air in homes, schools, and offices. Most of us spend much of our time indoors. The air that we breathe in our homes, in schools, and in offices can put us at risk for health problems. Some pollutants can be chemicals, gases, and living or

  10. CLL2-BXX Phase II trials: sequential, targeted treatment for eradication of minimal residual disease in chronic lymphocytic leukemia.

    PubMed

    Cramer, Paula; von Tresckow, Julia; Bahlo, Jasmin; Engelke, Anja; Langerbeins, Petra; Fink, Anna-Maria; Fischer, Kirsten; Wendtner, Clemens-Martin; Kreuzer, Karl-Anton; Stilgenbauer, Stephan; Böttcher, Sebastian; Eichhorst, Barbara; Hallek, Michael

    2018-03-01

    Four Phase II trials (clinical trials numbers: NCT02345863, NCT02401503, NCT02445131 and NCT02689141) evaluate a different combination of targeted agents in an all-comer population of approximately 60 patients with chronic lymphocytic leukemia irrespective of prior treatment, physical fitness and genetic risk factors. Patients with a higher tumor load start with a debulking treatment with bendamustine. The subsequent induction and maintenance treatment with an anti-CD20 antibody (obinutuzumab or ofatumumab) and a targeted oral agent (ibrutinib, idelalisib or venetoclax) are continued until achievement of a complete response and minimal residual disease negativity. This strategy represents a new era of chronic lymphocytic leukemia therapy where chemotherapy is increasingly replaced by targeted agents and treatment duration is tailored to the patient's individual tumor load and response.

  11. Enhancing indoor air quality -The air filter advantage.

    PubMed

    Vijayan, Vannan Kandi; Paramesh, Haralappa; Salvi, Sundeep Santosh; Dalal, Alpa Anil Kumar

    2015-01-01

    Air pollution has become the world's single biggest environmental health risk, linked to around 7 million deaths in 2012 according to a recent World Health Organisation (WHO) report. The new data further reveals a stronger link between, indoor and outdoor air pollution exposure and cardiovascular diseases, such as strokes and ischemic heart disease, as well as between air pollution and cancer. The role of air pollution in the development of respiratory diseases, including acute respiratory infections and chronic obstructive pulmonary diseases, is well known. While both indoor and outdoor pollution affect health, recent statistics on the impact of household indoor pollutants (HAP) is alarming. The WHO factsheet on HAP and health states that 3.8 million premature deaths annually - including stroke, ischemic heart disease, chronic obstructive pulmonary disease (COPD) and lung cancer are attributed to exposure to household air pollution. Use of air cleaners and filters are one of the suggested strategies to improve indoor air quality. This review discusses the impact of air pollutants with special focus on indoor air pollutants and the benefits of air filters in improving indoor air quality.

  12. [Indoor volatile organic compounds: concentrations, sources, variation factors].

    PubMed

    Palot, A; Charpin-Kadouch, C; Ercoli, J; Charpin, D

    2008-06-01

    Volatile organic compounds (V.O.C.) are part of urban air pollution and are also generated indoors from cleaning and maintenance products. VOC measurements are, on average, 10 times higher within homes than outside. Results of the national survey led by the Observatoire National de la Qualité de l'Air Intérieur demonstrated that up to 25% of French homes have very high or high concentrations of VOC. Indoor levels depend mainly on indoor sources. Aldehydes are included in many everyday life products. VOC originate from various household decorating and cleaning products. Some products are less detrimental to the environment and health and have special labelling. Indoor VOC levels also depend on the rate of air exchange and on household characteristics such as indoor temperature and humidity, age of the building, presence of smokers, and communication with a garage. The public may participate in maintaining good indoor air quality and the authorities should also improve regulations. VOC are part of everyday air pollution. Their sources and concentrations should be better monitored.

  13. Strategies to enhance the therapeutic efficacy of antidepressants: targeting residual symptoms

    PubMed Central

    Kurian, Benji T; Greer, Tracy L; Trivedi, Madhukar H

    2009-01-01

    Major depressive disorder (MDD) is an illness of great morbidity that affects many people across the world. The current goal for treatment of MDD is to achieve remission (i.e., no depressive symptoms). However, despite scientific advances in the treatment for MDD, antidepressants as first-line agents yield only modest remission rates. In fact, a recent study indicated that only one out of three subjects who received a standard, first-line antidepressant attained remission. Not achieving remission from depressive symptoms increases the risk of a more chronic and debilitating course of illness with frequent recurrences. Although a number of reasons contribute to these modest outcomes, the presence of residual symptoms is a major problem. Residual symptoms are defined as symptoms that linger despite an adequate dose and duration of an antidepressant medication. This article reviews the prevalence and clinical impact of common residual symptoms and discusses the utility of aggressively addressing residual symptoms to enhance the efficacy of antidepressant medications. PMID:19589048

  14. Cooperative Agreement Funding for Indoor Air Quality

    EPA Pesticide Factsheets

    The Indoor Environments Division has created partnership with public and private sector entities to help encourage the public to take action to minimize their risk and mitigate indoor air quality problems.

  15. Preliminary study of a millimeter wave FMCW InSAR for UAS indoor navigation.

    PubMed

    Scannapieco, Antonio F; Renga, Alfredo; Moccia, Antonio

    2015-01-22

    Small autonomous unmanned aerial systems (UAS) could be used for indoor inspection in emergency missions, such as damage assessment or the search for survivors in dangerous environments, e.g., power plants, underground railways, mines and industrial warehouses. Two basic functions are required to carry out these tasks, that is autonomous GPS-denied navigation with obstacle detection and high-resolution 3Dmapping with moving target detection. State-of-the-art sensors for UAS are very sensitive to environmental conditions and often fail in the case of poor visibility caused by dust, fog, smoke, flames or other factors that are met as nominal mission scenarios when operating indoors. This paper is a preliminary study concerning an innovative radar sensor based on the interferometric Synthetic Aperture Radar (SAR) principle, which has the potential to satisfy stringent requirements set by indoor autonomous operation. An architectural solution based on a frequency-modulated continuous wave (FMCW) scheme is proposed after a detailed analysis of existing compact and lightweight SAR. A preliminary system design is obtained, and the main imaging peculiarities of the novel sensor are discussed, demonstrating that high-resolution, high-quality observation of an assigned control volume can be achieved.

  16. Preliminary Study of a Millimeter Wave FMCW InSAR for UAS Indoor Navigation

    PubMed Central

    Scannapieco, Antonio F.; Renga, Alfredo; Moccia, Antonio

    2015-01-01

    Small autonomous unmanned aerial systems (UAS) could be used for indoor inspection in emergency missions, such as damage assessment or the search for survivors in dangerous environments, e.g., power plants, underground railways, mines and industrial warehouses. Two basic functions are required to carry out these tasks, that is autonomous GPS-denied navigation with obstacle detection and high-resolution 3D mapping with moving target detection. State-of-the-art sensors for UAS are very sensitive to environmental conditions and often fail in the case of poor visibility caused by dust, fog, smoke, flames or other factors that are met as nominal mission scenarios when operating indoors. This paper is a preliminary study concerning an innovative radar sensor based on the interferometric Synthetic Aperture Radar (SAR) principle, which has the potential to satisfy stringent requirements set by indoor autonomous operation. An architectural solution based on a frequency-modulated continuous wave (FMCW) scheme is proposed after a detailed analysis of existing compact and lightweight SAR. A preliminary system design is obtained, and the main imaging peculiarities of the novel sensor are discussed, demonstrating that high-resolution, high-quality observation of an assigned control volume can be achieved. PMID:25621606

  17. Targeting cattle for malaria elimination: marked reduction of Anopheles arabiensis survival for over six months using a slow-release ivermectin implant formulation.

    PubMed

    Chaccour, Carlos J; Ngha'bi, Kija; Abizanda, Gloria; Irigoyen Barrio, Angel; Aldaz, Azucena; Okumu, Fredros; Slater, Hannah; Del Pozo, Jose Luis; Killeen, Gerry

    2018-05-04

    Mosquitoes that feed on animals can survive and mediate residual transmission of malaria even after most humans have been protected with insecticidal bednets or indoor residual sprays. Ivermectin is a widely-used drug for treating parasites of humans and animals that is also insecticidal, killing mosquitoes that feed on treated subjects. Mass administration of ivermectin to livestock could be particularly useful for tackling residual malaria transmission by zoophagic vectors that evade human-centred approaches. Ivermectin comes from a different chemical class to active ingredients currently used to treat bednets or spray houses, so it also has potential for mitigating against emergence of insecticide resistance. However, the duration of insecticidal activity obtained with ivermectin is critical to its effectiveness and affordability. A slow-release formulation for ivermectin was implanted into cattle, causing 40 weeks of increased mortality among Anopheles arabiensis that fed on them. For this zoophagic vector of residual malaria transmission across much of Africa, the proportion surviving three days after feeding (typical mean duration of a gonotrophic cycle in field populations) was approximately halved for 25 weeks. This implantable ivermectin formulation delivers stable and sustained insecticidal activity for approximately 6 months. Residual malaria transmission by zoophagic vectors could be suppressed by targeting livestock with this long-lasting formulation, which would be impractical or unacceptable for mass treatment of human populations.

  18. Classroom ventilation and indoor air quality-results from the FRESH intervention study.

    PubMed

    Rosbach, J; Krop, E; Vonk, M; van Ginkel, J; Meliefste, C; de Wind, S; Gehring, U; Brunekreef, B

    2016-08-01

    Inadequate ventilation of classrooms may lead to increased concentrations of pollutants generated indoors in schools. The FRESH study, on the effects of increased classroom ventilation on indoor air quality, was performed in 18 naturally ventilated classrooms of 17 primary schools in the Netherlands during the heating seasons of 2010-2012. In 12 classrooms, ventilation was increased to targeted CO2 concentrations of 800 or 1200 ppm, using a temporary CO2 controlled mechanical ventilation system. Six classrooms were included as controls. In each classroom, data on endotoxin, β(1,3)-glucans, and particles with diameters of <10 μm (PM10 ) and <2.5 μm (PM2.5 ) and nitrogen dioxide (NO2 ) were collected during three consecutive weeks. Associations between the intervention and these measured indoor air pollution levels were assessed using mixed models, with random classroom effects. The intervention lowered endotoxin and β(1,3)-glucan levels and PM10 concentrations significantly. PM10 for instance was reduced by 25 μg/m³ (95% confidence interval 13-38 μg/m³) from 54 μg/m³ at maximum ventilation rate. No significant differences were found between the two ventilation settings. Concentrations of PM2.5 and NO2 were not affected by the intervention. Our results provide evidence that increasing classroom ventilation is effective in decreasing the concentrations of some indoor-generated pollutants. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Microbiological quality of indoor air in university libraries.

    PubMed

    Hayleeyesus, Samuel Fekadu; Manaye, Abayneh Melaku

    2014-05-01

    To evaluate the concentration of bacteria and fungi in the indoor environment of Jimma University libraries, so as to estimate the health hazard and to create standards for indoor air quality control. The microbial quality of indoor air of eight libraries of Jimma University was determined. The settle plate method using open Petri-dishes containing different culture media was employed to collect sample twice daily. Isolates were identified according to standard methods. The concentrations of bacteria and fungi aerosols in the indoor environment of the university libraries ranged between 367-2595 CFU/m(3). According to the sanitary standards classification of European Commission, almost all the libraries indoor air of Jimma University was heavily contaminated with bacteria and fungi. In spite of their major source difference, the average fungi density found in the indoor air of libraries did appear to follow the same trend with bacterial density (P=0.001). The bacteria isolates included Micrococcus sp., Staphylococcus aureus, Streptococcus pyogenes, Bacillus sp. and Neisseria sp. while Cladosporium sp., Alternaria sp., Penicillium sp. and Aspergillus sp. were the most isolated fungi. The indoor air of all libraries were in the range above highly contaminated according to European Commission classification and the most isolates are considered as potential candidates involved in the establishment of sick building syndromes and often associated with clinical manifestations like allergy, rhinitis, asthma and conjunctivitis. Thus, attention must be given to control those environmental factors which favor the growth and multiplication of microbes in indoor environment of libraries to safeguard the health of users and workers.

  20. Photocatalytic surface reactions on indoor wall paint.

    PubMed

    Salthammer, T; Fuhrmann, F

    2007-09-15

    The reduction of indoor air pollutants by air cleaning systems has received considerable interest, and a number of techniques are now available. So far, the method of photocatalysis was mainly applied by use of titanium dioxide (TiO2) in flow reactors under UV light of high intensity. Nowadays, indoor wall paints are equipped with modified TiO2 to work as a catalyst under indoor daylight or artificial light. In chamber experiments carried out under indoor related conditions itwas shown thatthe method works for nitrogen dioxide with air exchange and for formaldehyde without air exchange at high concentrations. In further experiments with volatile organic compounds (VOCs), a small effect was found for terpenoids with high kOH rate constants. For other VOCs and carbon monoxide there was no degradation at all or the surface acted as a reversible sink. Secondary emissions from the reaction of paint constituents were observed on exposure to light. From the results it is concluded that recipes of photocatalytic wall paints need to be optimized for better efficiency under indoor conditions.

  1. 9 CFR 3.26 - Facilities, indoor.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Pigs and Hamsters Facilities and Operating Standards § 3.26 Facilities, indoor. (a) Heating. Indoor housing facilities for guinea pigs or hamsters shall be sufficiently heated when necessary to protect the... pigs or hamsters shall be adequately ventilated to provide for the health and comfort of the animals at...

  2. 9 CFR 3.26 - Facilities, indoor.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Pigs and Hamsters Facilities and Operating Standards § 3.26 Facilities, indoor. (a) Heating. Indoor housing facilities for guinea pigs or hamsters shall be sufficiently heated when necessary to protect the... pigs or hamsters shall be adequately ventilated to provide for the health and comfort of the animals at...

  3. 9 CFR 3.26 - Facilities, indoor.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Pigs and Hamsters Facilities and Operating Standards § 3.26 Facilities, indoor. (a) Heating. Indoor housing facilities for guinea pigs or hamsters shall be sufficiently heated when necessary to protect the... pigs or hamsters shall be adequately ventilated to provide for the health and comfort of the animals at...

  4. 9 CFR 3.26 - Facilities, indoor.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Pigs and Hamsters Facilities and Operating Standards § 3.26 Facilities, indoor. (a) Heating. Indoor housing facilities for guinea pigs or hamsters shall be sufficiently heated when necessary to protect the... pigs or hamsters shall be adequately ventilated to provide for the health and comfort of the animals at...

  5. Thirdhand Smoke in the Homes of Medically Fragile Children: Assessing the Impact of Indoor Smoking Levels and Smoking Bans

    PubMed Central

    Matt, Georg E.; Hovell, Melbourne F.; Khan, Amir M.; Stotts, Angela L.

    2016-01-01

    Abstract Introduction: Thirdhand smoke (THS) residue results from secondhand smoke, and is emerging as a distinct public health hazard, particularly for medically fragile pediatric patients living with smokers. THS is difficult to remove and readily reacts with other pollutants to form carcinogens and ultrafine particles. This study investigated THS found in homes of high-risk infants admitted to a neonatal intensive care unit and their association with characteristics (eg, number of household smokers) hypothesized to influence THS. Methods: Baseline data from 141 hospitalized infants’ homes were analyzed, along with follow-up data ( n = 22) to explore household smoking characteristics and THS changes in response to indoor smoking ban policies. Results: Households with an indoor ban, in which not more than 10 cigarettes/d were smoked, had the lowest levels of THS contamination compared to homes with no ban ( P < .001) and compared to homes with an indoor ban in which greater numbers of cigarettes were smoked ( P < .001). Importantly, homes with an indoor ban in which at least 11 cigarettes/d were smoked were not different from homes without a ban. The follow-up sample of 22 homes provided initial evidence indicating that, unless a ban was implemented, THS levels in homes continued to increase over time. Conclusions: Preliminary longitudinal data suggest that THS may continue to accumulate in homes over time and household smoking bans may be protective. However, for homes with high occupant smoking levels, banning indoor smoking may not be fully adequate to protect children from THS. Unless smoking is reduced and bans are implemented, medically fragile children will be exposed to the dangers of THS. PMID:26315474

  6. Concentrations of indoor pollutants database: User's manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-05-01

    This manual describes the computer-based database on indoor air pollutants. This comprehensive database alloys helps utility personnel perform rapid searches on literature related to indoor air pollutants. Besides general information, it provides guidance for finding specific information on concentrations of indoor air pollutants. The manual includes information on installing and using the database as well as a tutorial to assist the user in becoming familiar with the procedures involved in doing bibliographic and summary section searches. The manual demonstrates how to search for information by going through a series of questions that provide search parameters such as pollutants type, year,more » building type, keywords (from a specific list), country, geographic region, author's last name, and title. As more and more parameters are specified, the list of references found in the data search becomes smaller and more specific to the user's needs. Appendixes list types of information that can be input into the database when making a request. The CIP database allows individual utilities to obtain information on indoor air quality based on building types and other factors in their own service territory. This information is useful for utilities with concerns about indoor air quality and the control of indoor air pollutants. The CIP database itself is distributed by the Electric Power Software Center and runs on IBM PC-compatible computers.« less

  7. Specific residues of the cytoplasmic domains of cardiac inward rectifier potassium channels are effective antifibrillatory targets

    PubMed Central

    Noujaim, Sami F.; Stuckey, Jeanne A.; Ponce-Balbuena, Daniela; Ferrer-Villada, Tania; López-Izquierdo, Angelica; Pandit, Sandeep; Calvo, Conrado J.; Grzeda, Krzysztof R.; Berenfeld, Omer; Sánchez Chapula, José A.; Jalife, José

    2010-01-01

    Atrial and ventricular tachyarrhythmias can be perpetuated by up-regulation of inward rectifier potassium channels. Thus, it may be beneficial to block inward rectifier channels under conditions in which their function becomes arrhythmogenic (e.g., inherited gain-of-function mutation channelopathies, ischemia, and chronic and vagally mediated atrial fibrillation). We hypothesize that the antimalarial quinoline chloroquine exerts potent antiarrhythmic effects by interacting with the cytoplasmic domains of Kir2.1 (IK1), Kir3.1 (IKACh), or Kir6.2 (IKATP) and reducing inward rectifier potassium currents. In isolated hearts of three different mammalian species, intracoronary chloroquine perfusion reduced fibrillatory frequency (atrial or ventricular), and effectively terminated the arrhythmia with resumption of sinus rhythm. In patch-clamp experiments chloroquine blocked IK1, IKACh, and IKATP. Comparative molecular modeling and ligand docking of chloroquine in the intracellular domains of Kir2.1, Kir3.1, and Kir6.2 suggested that chloroquine blocks or reduces potassium flow by interacting with negatively charged amino acids facing the ion permeation vestibule of the channel in question. These results open a novel path toward discovering antiarrhythmic pharmacophores that target specific residues of the cytoplasmic domain of inward rectifier potassium channels.—Noujaim, S. F., Stuckey, J. A., Ponce-Balbuena, D., Ferrer-Villada, T., López-Izquierdo, A., Pandit, S., Calvo, C. J., Grzeda, K. R., Berenfeld, O., Sánchez Chapula, J. A., Jalife, J. Specific residues of the cytoplasmic domains of cardiac inward rectifier potassium channels are effective antifibrillatory targets. PMID:20585026

  8. Constructing an Indoor Floor Plan Using Crowdsourcing Based on Magnetic Fingerprinting

    PubMed Central

    Zhao, Fang; Jiang, Mengling; Ma, Hao; Zhang, Yuexia

    2017-01-01

    A large number of indoor positioning systems have recently been developed to cater for various location-based services. Indoor maps are a prerequisite of such indoor positioning systems; however, indoor maps are currently non-existent for most indoor environments. Construction of an indoor map by external experts excludes quick deployment and prevents widespread utilization of indoor localization systems. Here, we propose an algorithm for the automatic construction of an indoor floor plan, together with a magnetic fingerprint map of unmapped buildings using crowdsourced smartphone data. For floor plan construction, our system combines the use of dead reckoning technology, an observation model with geomagnetic signals, and trajectory fusion based on an affinity propagation algorithm. To obtain the indoor paths, the magnetic trajectory data obtained through crowdsourcing were first clustered using dynamic time warping similarity criteria. The trajectories were inferred from odometry tracing, and those belonging to the same cluster in the magnetic trajectory domain were then fused. Fusing these data effectively eliminates the inherent tracking errors originating from noisy sensors; as a result, we obtained highly accurate indoor paths. One advantage of our system is that no additional hardware such as a laser rangefinder or wheel encoder is required. Experimental results demonstrate that our proposed algorithm successfully constructs indoor floor plans with 0.48 m accuracy, which could benefit location-based services which lack indoor maps. PMID:29156639

  9. Indoor Air Quality Basics for Schools.

    ERIC Educational Resources Information Center

    Environmental Protection Agency, Washington, DC. Office of Radiation and Indoor Air.

    This fact sheet details important information on Indoor Air Quality (IAQ) in school buildings, problems associated with IAQ, and various prevention and problem-solving strategies. Most people spend 90 percent of their time indoors, therefore the Environmental Protection Agency ranks IAQ in the top four environmental risks to the public. The…

  10. Publications and Resources About Indoor airPLUS

    EPA Pesticide Factsheets

    Presented are useful materials to help you build homes that meet Indoor airPLUS specifications and to promote Indoor airPLUS qualified homes. These materials are FREE of charge and are available in PDF.

  11. Federal Interagency Committee on Indoor Air Quality

    EPA Pesticide Factsheets

    The Federal Interagency Committee on Indoor Air Quality (CIAQ), which meets three times a year, was established by Congress to coordinate the activities of the Federal Government on issues relating to Indoor Air Quality.

  12. Indoor airPLUS Sales and Marketing Resources

    EPA Pesticide Factsheets

    Presented are useful materials to help you build homes that meet Indoor airPLUS specifications and to promote Indoor airPLUS qualified homes. These materials are FREE of charge and are available in PDF.

  13. Impact of Presence of Children on Indoor Tobacco Restrictions in Households of Urban and Rural Adult Tobacco Users.

    PubMed

    Kopp, Benjamin T; Hinton, Alice; Lu, Rong; Cooper, Sarah; Nagaraja, Haikady; Wewers, Mary Ellen

    2018-04-10

    Secondhand smoke exposure in children is changing as a result of new public policy and electronic nicotine products (e-cigarettes). We examined factors related to self-imposed indoor household tobacco restrictions, with emphasis on children in the household and associations with combustible and noncombustible product use. A cross-sectional survey of urban and rural Ohio adult tobacco users classified participants as exclusive combustible users, smokeless tobacco (SLT) users, e-cigarette users, or dual users. They were further stratified according to combustible or noncombustible product use and the presence of indoor tobacco use restrictions. Multiple logistic regression determined factors associated with indoor tobacco restrictions. A total of 1210 tobacco users participated, including 25.7% with children living in the home. Half allowed combustible and two thirds allowed noncombustible tobacco use indoors. Urban location (odds ratio [OR] = 1.58), younger age (OR = 0.88 per 5 year), male sex (OR = 1.40), college education (OR = 1.40), household income of more than $15,000 (OR = 1.78), and being married (OR = 2.43) were associated with a higher likelihood of banning combustible products indoors. SLT (OR = 8.12) and e-cigarette (OR = 5.85) users were more likely to have indoor bans compared to combustible users. Children in the household (OR = 1.89), older age (OR = 1.12 per 5 years), and nonwhite race (OR = 1.68) were associated with a higher likelihood of banning noncombustible products indoors. Combustible (OR = 4.54) and e-cigarette (OR = 3.04) users were more likely than SLT users to have indoor bans. Indoor restrictions on tobacco use remain infrequent in homes with children and are associated with user type and socioeconomic factors. Public policy should target modifiable risk factors for in-home secondhand smoke exposure. Copyright © 2018 Academic Pediatric Association. Published by Elsevier Inc. All

  14. Comparison of advertising strategies between the indoor tanning and tobacco industries.

    PubMed

    Greenman, Jennifer; Jones, David A

    2010-04-01

    The indoor tanning industry is large and continues to grow, with 2007 domestic sales in excess of $5 billion. Advertising is central to shaping the consumer's perception of indoor tanning as well as driving industry demand. This article aims to identify key drivers of consumer appeal by comparing tanning advertising strategies to those used by tobacco marketers. Tobacco advertising was selected as a reference framework because it is both well documented and designed to promote a product with known health hazards. Two thousand advertisements from 4 large tobacco advertisement databases were analyzed for type of advertisement strategy used, and 4 advertising method categories were devised to incorporate the maximum number of advertisements reviewed. Subsequently, contemporary tanning advertisements were collected from industry magazines and salon websites and evaluated relative to the identified strategy profiles. Both industries have relied on similar advertising strategies, including mitigating health concerns, appealing to a sense of social acceptance, emphasizing psychotropic effects, and targeting specific population segments. This examination is a small observational study, which was conducted without rigorous statistical analysis, and which is limited both by the number of advertisements and by advertising strategies examined. Given the strong parallels between tobacco and tanning advertising methodologies, further consumer education and investigation into the public health risks of indoor tanning is needed. Copyright 2009 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.

  15. REVIEW OF INDOOR EMISSION SOURCE MODELS--PART 1. OVERVIEW

    EPA Science Inventory

    Indoor emission source models are mainly used as a component in indoor air quality (IAQ) and exposure modeling. They are also widely used to interpret the experimental data obtained from environmental chambers and buildings. This paper compiles 46 indoor emission source models fo...

  16. Indoor and outdoor falls among older adult trauma patients: A comparison of patient characteristics, associated factors and outcomes.

    PubMed

    Chippendale, Tracy; Gentile, Patricia A; James, Melissa K; Melnic, Gloria

    2017-06-01

    The aim of the present study was to examine significant differences in patient characteristics, associated factors and outcomes for indoor versus outdoor falls among trauma patients. A retrospective cross-sectional study using data from the trauma registry and electronic medical records at a level 1 trauma center in the USA was carried out. People aged 55 years or older, for whom fall location could be identified (n = 712), were included in the study. Demographic information, functional status before admission, comorbid conditions, activation level, Injury Severity Score, discharge disposition and injury type were included in the comparative analyses. Associated factors for falls and fractures in each location were also examined using logistic regression. Significant differences were found in patient characteristics between indoor and outdoor fallers. Significant differences in outcomes were found related to discharge disposition and injury type. Open wounds were more common among outdoor fallers (26.5%) as compared with indoor fallers (16.3%, P = 0.002). Although disorders of joints with difficulty walking were associated with fractures among both indoor (OR 7.20, CI 2.19-23.66) and outdoor fallers (OR 5.65, CI 1.27-25.06), sex was only associated with fractures among those who fell indoors (OR 1.69 CI 1.12-2.56). Significant differences exist in characteristics of indoor and outdoor fallers, and for discharge disposition and injury type for each fall location among patients admitted for trauma care. Factors associated with fractures differ between indoor and outdoor fallers. Results can help to inform targeted primary and secondary prevention initiatives. Geriatr Gerontol Int 2017; 17: 905-912. © 2016 Japan Geriatrics Society.

  17. A simulation model of building intervention impacts on indoor environmental quality, pediatric asthma, and costs

    PubMed Central

    Fabian, Maria Patricia; Adamkiewicz, Gary; Stout, Natasha Kay; Sandel, Megan; Levy, Jonathan Ian

    2013-01-01

    Background Although indoor environmental conditions can affect pediatric asthmatics, few studies have characterized the impact of building interventions on asthma-related outcomes. Simulation models can evaluate such complex systems but have not been applied in this context. Objective To evaluate the impacts of building interventions on indoor environmental quality and pediatric asthma healthcare utilization, and to conduct cost comparisons between intervention and healthcare costs, and energy savings. Methods We applied our previously developed discrete event simulation model (DEM) to simulate the effect of environmental factors, medication compliance, seasonality, and medical history on: 1) pollutant concentrations indoors, and 2) asthma outcomes in low-income multi-family housing. We estimated healthcare utilization and costs at baseline and subsequent to interventions, and then compared healthcare costs to energy savings and intervention costs. Results Interventions such as integrated pest management and repairing kitchen exhaust fans led to 7–12% reductions in serious asthma events with 1–3 year payback periods. Weatherization efforts targeted solely towards tightening a building envelope led to 20% more serious asthma events, but bundling with repairing kitchen exhaust fans and eliminating indoor sources (e.g. gas stoves or smokers) mitigated this impact. Conclusion Our pediatric asthma model provides a tool to prioritize individual and bundled building interventions based on their impact on health and cost, and highlighting the tradeoffs between weatherization, indoor air quality, and health. Our work bridges the gap between clinical and environmental health sciences by increasing physicians’ understanding of the impact that home environmental changes can have on their patients’ asthma. PMID:23910689

  18. A deep learning framework for improving long-range residue-residue contact prediction using a hierarchical strategy.

    PubMed

    Xiong, Dapeng; Zeng, Jianyang; Gong, Haipeng

    2017-09-01

    Residue-residue contacts are of great value for protein structure prediction, since contact information, especially from those long-range residue pairs, can significantly reduce the complexity of conformational sampling for protein structure prediction in practice. Despite progresses in the past decade on protein targets with abundant homologous sequences, accurate contact prediction for proteins with limited sequence information is still far from satisfaction. Methodologies for these hard targets still need further improvement. We presented a computational program DeepConPred, which includes a pipeline of two novel deep-learning-based methods (DeepCCon and DeepRCon) as well as a contact refinement step, to improve the prediction of long-range residue contacts from primary sequences. When compared with previous prediction approaches, our framework employed an effective scheme to identify optimal and important features for contact prediction, and was only trained with coevolutionary information derived from a limited number of homologous sequences to ensure robustness and usefulness for hard targets. Independent tests showed that 59.33%/49.97%, 64.39%/54.01% and 70.00%/59.81% of the top L/5, top L/10 and top 5 predictions were correct for CASP10/CASP11 proteins, respectively. In general, our algorithm ranked as one of the best methods for CASP targets. All source data and codes are available at http://166.111.152.91/Downloads.html . hgong@tsinghua.edu.cn or zengjy321@tsinghua.edu.cn. Supplementary data are available at Bioinformatics online. © The Author (2017). Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  19. Indoor Air Quality: Maryland Public Schools.

    ERIC Educational Resources Information Center

    Maryland State Dept. of Education, College Park. Office of Administration and Finance.

    Less than adequate indoor air quality in schools can lead to a higher risk of health problems, an increase in student and teacher absenteeism, diminished learning, and even hazardous conditions. An indoor air quality program that addresses the planning, design, maintenance, and operation of public school buildings should be implemented at the…

  20. Mold and Indoor Air Quality in Schools

    MedlinePlus

    ... Centers Mold Contact Us Share Mold and Indoor Air Quality in Schools Mold and Moisture in Schools Webinar ... premier resource on this issue is the Indoor Air Quality Tools for Schools kit. Our schools-related resources ...

  1. About the Subdivision of Indoor Spaces in Indoorgml

    NASA Astrophysics Data System (ADS)

    Diakité, A. A.; Zlatanova, S.; Li, K.-J.

    2017-10-01

    Boosted by the dynamic urbanization of cities, indoor environments are getting more and more complex in order to be able to host people properly. While most of our time is spent inside buildings, the need of GIS tools to assist our daily activities that can become tedious, such as indoor navigation or facility management, became more and more urgent. In that perspective, the IndoorGML standard is aiming to address the gaps left by other standards regarding the spatial modelling for indoor navigation. It includes several concepts such as the organization of the spaces into cells along with their network representation and the possibility to represent multiple connected layers. However, being at its first stage, several concepts of the standard could be improved. One of these is the cell subspacing that is not enough discussed in the current version of the standard. In this paper, we explore all the aspects involved in the subdivision process, from the identification of the navigable and non-navigable space cells to the generation of a navigation graph. We propose several criteria on which the indoor sub-spacing can rely to be automatically performed and and illustrate them on a 3D indoor model.

  2. Hourly indoor radon measurements in a research house.

    PubMed

    Sesana, Lucia; Begnini, Stefania

    2004-01-01

    This paper reports and discusses the behaviour of radon concentration with time in an uninhabited dwelling. The relationship between variations in radon concentrations and indoor-outdoor temperatures and wind intensity has also been discussed. Radon concentration was measured hourly in a house located at a height of 800 m in the Lombard Prealps, at the top of the Valassina valley. The wind velocity and indoor-outdoor temperatures were measured by means of a meteorological station located on the terrace of the house. The data were analysed using the LBL model for indoor-outdoor air exchange and the models for the indoor accumulation of radon due to exhalation from building materials and pressure-driven infiltrations located underground. The role of wind and indoor-outdoor temperatures were analysed. The agreement of measurements with modelling clearly demonstrates the importance of the different sources of indoor radon. As the investigation was conducted in an uninhabited house, the measurements were not affected by the behaviour of people, e.g. opening and closing of windows. Measurements of the outdoor atmospheric concentrations of (222)Rn provide an index of the atmospheric stability, the formation of thermal inversions and convective turbulence.

  3. Indoor localization using FM radio and DTMB signals

    NASA Astrophysics Data System (ADS)

    Wu, H.; Wang, Q.; Zhao, Y.; Ma, X.; Yang, M.; Liu, B.; Tang, R.; Xu, X.

    2016-07-01

    Indoor localization systems based on Wi-Fi signal strength fingerprinting techniques are widely used in office buildings. However, a general problem of these systems pertains to Wi-Fi signal degradation due to the environmental factors. And also, these systems cannot be used in the environments not covered with Wi-Fi signals or the environments with only a single Wi-Fi access point. In this paper, a new indoor location fingerprinting system using both FM radio and Digital Television Terrestrial Multimedia Broadcasting (DTMB) signals is proposed. First, the indoor location fingerprinting using FM radio and DTMB signals is theoretically analyzed to confirm its feasibility. Then, a specially designed combined strength fingerprinting location algorithm is proposed for the location system, which is achieved on the USRP2 platform. Finally, the system is tested in a typical indoor environment. The theoretical analysis and the tests show that the indoor location fingerprinting system using FM radio and DTMB signals has a similar localization accuracy to the Wi-Fi signal strength fingerprinting location system, while it has a wider coverage area, a lower maintenance cost, and more stable signal strength, which makes it a practical indoor positioning method.

  4. Immediate impact of smoke-free laws on indoor air quality.

    PubMed

    Lee, Kiyoung; Hahn, Ellen J; Riker, Carol; Head, Sara; Seithers, Peggy

    2007-09-01

    Smoke-free laws significantly impact indoor air quality. However, the temporal effects of these laws on indoor air pollution have not been determined. This paper assesses the temporal impact of one smoke-free law on indoor air quality. This quasi-experimental study compared the indoor air quality of nine hospitality venues and one bingo hall in Georgetown, Kentucky, before and after implementation of a 100% smoke-free workplace law. We made real-time measurements of particulate matter with 2.5 microm aerodynamic diameter or smaller (PM2.5). Among the nine Georgetown hospitality venues, the average indoor PM2.5 concentration was 84 microg/m3 before the law took effect. The average indoor PM2.5 concentrations in nine compliant venues significantly decreased to 18 microg/m3 one week after the law took effect. Three venues having 82 microg/m3 before the law had significantly lower levels from the first day the law was implemented, and the low level was maintained. Compliance with the law is critical to achieving clean indoor air. Indoor air pollution in the bingo hall was not reduced until the establishment decided to comply with the law. The smoke-free law showed immediate impact on indoor air quality.

  5. Engaging Moms on Teen Indoor Tanning Through Social Media: Protocol of a Randomized Controlled Trial.

    PubMed

    Pagoto, Sherry L; Baker, Katie; Griffith, Julia; Oleski, Jessica L; Palumbo, Ashley; Walkosz, Barbara J; Hillhouse, Joel; Henry, Kimberly L; Buller, David B

    2016-11-29

    Indoor tanning elevates the risk for melanoma, which is now the most common cancer in US women aged 25-29. Public policies restricting access to indoor tanning by minors to reduce melanoma morbidity and mortality in teens are emerging. In the United States, the most common policy restricting indoor tanning in minors involves parents providing either written or in person consent for the minor to purchase a tanning visit. The effectiveness of this policy relies on parents being properly educated about the harms of indoor tanning to their children. This randomized controlled trial will test the efficacy of a Facebook-delivered health communication intervention targeting mothers of teenage girls. The intervention will use health communication and behavioral modification strategies to reduce mothers' permissiveness regarding their teenage daughters' use of indoor tanning relative to an attention-control condition with the ultimate goal of reducing indoor tanning in both daughters and mothers. The study is a 12-month randomized controlled trial comparing 2 conditions: an attention control Facebook private group where content will be relevant to teen health with 25% focused on prescription drug abuse, a topic unrelated to tanning; and the intervention condition will enter participants into a Facebook private group where 25% of the teen health content will be focused on indoor tanning. A cohort of 2000 mother-teen daughter dyads will be recruited to participate in this study. Only mothers will participate in the Facebook groups. Both mothers and daughters will complete measures at baseline, end of intervention (1-year) and 6 months post-intervention. Primary outcomes include mothers' permissiveness regarding their teenage daughters' use of indoor tanning, teenage daughters' perception of their mothers' permissiveness, and indoor tanning by both mothers and daughters. The first dyad was enrolled on March 31, 2016, and we anticipate completing this study by October 2019

  6. Criegee intermediates in the indoor environment. New insights

    DOE PAGES

    Shallcross, D. E.; Taatjes, C. A.; Percival, C. J.

    2014-03-25

    Criegee intermediates are formed in the ozonolysis of alkenes and play an important role in indoor chemistry, notably as a source of OH radicals. Recent studies have shown that these Criegee intermediates react very quickly with NO 2, SO 2, and carbonyls, and in this study, steady-state calculations are used to inspect the potential impact of these data on indoor chemistry. It is shown that these reactions could accelerate NO 3 formation and SO 2 removal in the indoor environment significantly. In addition, reaction between Criegee intermediates and halogenated carbonyls could provide a significant loss process indoors, where currently onemore » does not exist.« less

  7. Indoor air pollution and preventions in college libraries

    NASA Astrophysics Data System (ADS)

    Yang, Zengzhang

    2017-05-01

    The college library is a place where it gets the comparatively high density of students often staying long time with it. Therefore, the indoor air quality will affect directly reading effect and physical health of teachers and students in colleges and universities. The paper analyzes the influenced factors in indoor air pollution of the library from the selection of green-environmental decorating materials and furniture, good ventilation maintaining, electromagnetic radiation reducing, regular disinfection, indoor green building and awareness of health and environmental protection strengthening etc. six aspects to put forward the ideas for preventions of indoor air pollution and construction of the green low-carbon library.

  8. Dynamic behavior of semivolatile organic compounds in indoor air

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loy, Michael David Van

    1998-12-09

    Exposures to a wide range of air pollutants are often dominated by those occurring in buildings because of three factors: 1) most people spend a large fraction of their time indoors, 2) many pollutants have strong indoor sources, and 3) the dilution volume in buildings is generally several orders of magnitude smaller than that of an urban airshed. Semivolatile organic compounds (SVOCS) are emitted by numerous indoor sources, including tobacco combustion, cooking, carpets, paints, resins, and glues, so indoor gasphase concentrations of these compounds are likely to be elevated relative to ambient levels. The rates of uptake and release ofmore » reversibly sorbing SVOCS by indoor materials directly affect both peak concentrations and persistence of the pollutants indoors after source elimination. Thus, accurate predictions of SVOC dynamics in indoor air require an understanding of contaminant sorption on surface materials such as carpet and wallboard. The dynamic behaviors of gas-phase nicotine and phenanthrene were investigated in a 20 ms stainless steel chamber containing carpet and painted wallboard. Each compound was studied independently, first in the empty chamber, then with each sorbent individually, and finally with both sorbents in the chamber.« less

  9. Indoor Air Problems and Hoarseness in Children.

    PubMed

    Kallvik, Emma; Putus, Tuula; Simberg, Susanna

    2016-01-01

    A well-functioning voice is becoming increasingly important because voice-demanding professions are increasing. The largest proportion of voice disorders is caused by factors in the environment. Moisture damage is common and can initiate microbial growth and/or diffusion of chemicals from building materials. Indoor air problems due to moisture damage are associated with a number of health symptoms, for example, rhinitis, cough, and asthma symptoms. The purpose of this study was to investigate if children attending a day care center, preschool, or school with indoor air problems due to moisture damage were hoarse more often than the children in a control group. Information was collected through electronic and paper questionnaires from the parents of 6- to 9-year-old children (n = 1857) attending 57 different day care centers, preschools, or schools with or without indoor air problems due to moisture damage. The results showed a significant correlation between the degree of indoor air problem due to moisture damage and the frequency of hoarseness. Significant predictors for the child being hoarse every week or more often were dry cough, phlegm cough, and nasal congestion. The results indicate that these symptoms and exposure to indoor air problems due to moisture damage should be included in voice anamnesis. Furthermore, efforts should be made to remediate indoor air problems due to moisture damage and to treat health symptoms. Copyright © 2016 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  10. Monitoring Indoor Air Quality for Enhanced Occupational Health.

    PubMed

    Pitarma, Rui; Marques, Gonçalo; Ferreira, Bárbara Roque

    2017-02-01

    Indoor environments are characterized by several pollutant sources. Because people spend more than 90% of their time in indoor environments, several studies have pointed out the impact of indoor air quality on the etiopathogenesis of a wide number of non-specific symptoms which characterizes the "Sick Building Syndrome", involving the skin, the upper and lower respiratory tract, the eyes and the nervous system, as well as many building related diseases. Thus, indoor air quality (IAQ) is recognized as an important factor to be controlled for the occupants' health and comfort. The majority of the monitoring systems presently available is very expensive and only allow to collect random samples. This work describes the system (iAQ), a low-cost indoor air quality monitoring wireless sensor network system, developed using Arduino, XBee modules and micro sensors, for storage and availability of monitoring data on a web portal in real time. Five micro sensors of environmental parameters (air temperature, humidity, carbon monoxide, carbon dioxide and luminosity) were used. Other sensors can be added for monitoring specific pollutants. The results reveal that the system can provide an effective indoor air quality assessment to prevent exposure risk. In fact, the indoor air quality may be extremely different compared to what is expected for a quality living environment. Systems like this would have benefit as public health interventions to reduce the burden of symptoms and diseases related to "sick buildings".

  11. OBSTRUCTIVE LUNG DISEASE AND EXPOSURE TO BURNING BIOMASS FUEL IN THE INDOOR ENVIRONMENT.

    PubMed

    Diette, Gregory B; Accinelli, Roberto A; Balmes, John R; Buist, A Sonia; Checkley, William; Garbe, Paul; Hansel, Nadia N; Kapil, Vikas; Gordon, Stephen; Lagat, David K; Yip, Fuyuen; Mortimer, Kevin; Perez-Padilla, Rogelio; Roth, Christa; Schwaninger, Julie M; Punturieri, Antonello; Kiley, James

    2012-09-01

    It is estimated that up to half of the world's population burns biomass fuel (wood, crop residues, animal dung and coal) for indoor uses such as cooking, lighting and heating. As a result, a large proportion of women and children are exposed to high levels of household air pollution (HAP). The short and long term effects of these exposures on the respiratory health of this population are not clearly understood. On May 9-11, 2011 NIH held an international workshop on the "Health Burden of Indoor Air Pollution on Women and Children," in Arlington, VA. To gather information on the knowledge base on this topic and identify research gaps, ahead of the meeting we conducted a literature search using PubMed to identify publications that related to HAP, asthma, and chronic obstructive pulmonary disease (COPD). Abstracts were all analyzed and we report on those considered by the respiratory sub study group at the meeting to be most relevant to the field. Many of the studies published are symptom-based studies (as opposed to objective measures of lung function or clinical examination etc.) and measurement of HAP was not done. Many found some association between indoor exposures to biomass smoke as assessed by stove type (e.g., open fire vs. liquid propane gas) and respiratory symptoms such as wheeze and cough. Among the studies that examined objective measures (e.g. spirometry) as a health outcome, the data supporting an association between biomass smoke exposure and COPD in adult women are fairly robust, but the findings for asthma are mixed. If an association was observed between the exposures and lung function, most data seemed to demonstrate mild to moderate reductions in lung function, the pathophysiological mechanisms of which need to be investigated. In the end, the group identified a series of scientific gaps and opportunities for research that need to be addressed to better understand the respiratory effects of exposure to indoor burning of the different forms of

  12. OBSTRUCTIVE LUNG DISEASE AND EXPOSURE TO BURNING BIOMASS FUEL IN THE INDOOR ENVIRONMENT

    PubMed Central

    Diette, Gregory B.; Accinelli, Roberto A.; Balmes, John R.; Buist, A. Sonia; Checkley, William; Garbe, Paul; Hansel, Nadia N.; Kapil, Vikas; Gordon, Stephen; Lagat, David K.; Yip, Fuyuen; Mortimer, Kevin; Perez-Padilla, Rogelio; Roth, Christa; Schwaninger, Julie M.; Punturieri, Antonello; Kiley, James

    2012-01-01

    It is estimated that up to half of the world’s population burns biomass fuel (wood, crop residues, animal dung and coal) for indoor uses such as cooking, lighting and heating. As a result, a large proportion of women and children are exposed to high levels of household air pollution (HAP). The short and long term effects of these exposures on the respiratory health of this population are not clearly understood. On May 9–11, 2011 NIH held an international workshop on the "Health Burden of Indoor Air Pollution on Women and Children," in Arlington, VA. To gather information on the knowledge base on this topic and identify research gaps, ahead of the meeting we conducted a literature search using PubMed to identify publications that related to HAP, asthma, and chronic obstructive pulmonary disease (COPD). Abstracts were all analyzed and we report on those considered by the respiratory sub study group at the meeting to be most relevant to the field. Many of the studies published are symptom-based studies (as opposed to objective measures of lung function or clinical examination etc.) and measurement of HAP was not done. Many found some association between indoor exposures to biomass smoke as assessed by stove type (e.g., open fire vs. liquid propane gas) and respiratory symptoms such as wheeze and cough. Among the studies that examined objective measures (e.g. spirometry) as a health outcome, the data supporting an association between biomass smoke exposure and COPD in adult women are fairly robust, but the findings for asthma are mixed. If an association was observed between the exposures and lung function, most data seemed to demonstrate mild to moderate reductions in lung function, the pathophysiological mechanisms of which need to be investigated. In the end, the group identified a series of scientific gaps and opportunities for research that need to be addressed to better understand the respiratory effects of exposure to indoor burning of the different forms of

  13. Antimicrobial Treatments of Indoor Mold and Bacteria

    EPA Science Inventory

    Biological contaminants especially mold in buildings are known to act as sources of indoor air pollution, discomfort, asthma and pulmonary disease to building occupants. Sick buildings are evidence of extremely problematic indoor air quality (IAQ), often resulting from unacceptab...

  14. The selenazal drug ebselen potently inhibits indoleamine 2,3-dioxygenase by targeting enzyme cysteine residues.

    PubMed

    Terentis, Andrew C; Freewan, Mohammed; Sempértegui Plaza, Tito S; Raftery, Mark J; Stocker, Roland; Thomas, Shane R

    2010-01-26

    The heme enzyme indoleamine 2,3-dioxygenase (IDO) plays an important immune regulatory role by catalyzing the oxidative degradation of l-tryptophan. Here we show that the selenezal drug ebselen is a potent IDO inhibitor. Exposure of human macrophages to ebselen inhibited IDO activity in a manner independent of changes in protein expression. Ebselen inhibited the activity of recombinant human IDO (rIDO) with an apparent inhibition constant of 94 +/- 17 nM. Optical and resonance Raman spectroscopy showed that ebselen altered the active site heme of rIDO by inducing a transition of the ferric heme iron from the predominantly high- to low-spin form and by lowering the vibrational frequency of the Fe-CO stretch of the CO complex, indicating an opening of the distal heme pocket. Substrate binding studies showed that ebselen enhanced nonproductive l-tryptophan binding, while circular dichroism indicated that the drug reduced the helical content and protein stability of rIDO. Thiol labeling and mass spectrometry revealed that ebselen reacted with multiple cysteine residues of IDO. Removal of cysteine-bound ebselen with dithiothreitol reversed the effects of the drug on the heme environment and significantly restored enzyme activity. These findings indicate that ebselen inhibits IDO activity by reacting with the enzyme's cysteine residues that result in changes to protein conformation and active site heme, leading to an increase in the level of nonproductive substrate binding. This study highlights that modification of cysteine residues is a novel and effective means of inhibiting IDO activity. It also suggests that IDO is under redox control and that the enzyme represents a previously unrecognized in vivo target of ebselen.

  15. Indoor-outdoor levels of size segregated particulate matter and mono/polycyclic aromatic hydrocarbons among urban areas using solid fuels for heating

    NASA Astrophysics Data System (ADS)

    Kliucininkas, Linas; Krugly, Edvinas; Stasiulaitiene, Inga; Radziuniene, Inga; Prasauskas, Tadas; Jonusas, Arunas; Kauneliene, Violeta; Martuzevicius, Dainius

    2014-11-01

    Emissions from the fuel combustion in the energy production are causes of concern due to associated health risks, but little information is available on the impact of residential fuel burning on indoor air quality, where most of the human exposure occurs. In this complex study, concentrations of size-segregated particulate matter (PM), monocyclic and polycyclic aromatic compounds (MAHs and PAHs) at indoor and outdoor sites in six urban homes in the city of Kaunas, Lithuania, were determined over winter and summer sampling campaigns, specifically targeting the impact of the local fuel burning to the indoor air quality. PM levels observed in Kaunas during winter measurement campaign were higher compared to those in many other European settlements utilizing biomass for energy production. The particle size distribution analysis revealed that the major part of the PM mass in winter period consisted of fine particles (PM2.5). Both MAH and PAH levels were higher in winter. The indoor to outdoor ratios (I/O) of MAHs and PAHs revealed specific patterns depending on the presence of emissions sources indoors. Irrespectively of the season, I/O values were <1, suggesting that in case of the absence of an indoor pollution, the dominant source of organic compounds was from the outdoor environment. In homes with no PAH source inside, the I/O ratio equalled ranged from 0.05 to 0.36, suggesting the penetrated portion of outdoor combustion particles to the indoor air.

  16. Prevalence and Correlates of Indoor Tanning among U.S. Adults

    PubMed Central

    Heckman, Carolyn J.; Coups, Elliot J.; Manne, Sharon L.

    2008-01-01

    Background Little is known about the prevalence of indoor tanning among the U.S. general adult population. Objectives This study sought to (1) describe the prevalence of indoor tanning throughout adulthood, (2) identify demographic and psychosocial correlates of indoor tanning, and (3) determine whether these correlates vary by age group. Methods This study used data from the 2005 National Health Interview Survey, an annual health survey of the U.S. adult population. Results Indoor tanning rates were higher among individuals who were young, white, and female. Rates of indoor tanning in the last year varied from 20.4% for 18−29 year-olds to 7.8% for those 65 years and older. A variety of demographic, health, and behavioral health risk factors correlated with indoor tanning. Limitations The study design was cross-sectional and all data were self-reported. Conclusions Health care providers should address indoor tanning as a health risk factor across the lifespan. PMID:18328594

  17. The window of opportunity for indoor tanning legislation.

    PubMed

    Mayer, Jonathan E

    2014-12-01

    As of August 2014, 11 states in the USA have passed under-age-18 bans on indoor tanning. The Society of Behavioral Medicine, the American Academy of Dermatology, and the American Academy of Pediatrics have all issued statements in support of an under-age-18 ban. The World Health Organization and the Food and Drug Administration have both declared indoor tanning devices as carcinogenic, and this year, the Surgeon General for the first time issued a warning on the dangers of UV radiation and indoor tanning. This essay highlights how the awareness of the risks of indoor tanning, effective policies, and a conducive political atmosphere have aligned to create a window of opportunity for further under-age-18 indoor tanning legislation. The rising number of preventable skin cancers and mortalities is an issue that transcends political party lines, and now, there is a need for support from health professionals and advocates to motivate legislators to push new under-age-18 bills past their sticking points.

  18. Assessment of the impact of oxidation processes on indoor air pollution using the new time-resolved INCA-Indoor model

    NASA Astrophysics Data System (ADS)

    Mendez, Maxence; Blond, Nadège; Blondeau, Patrice; Schoemaecker, Coralie; Hauglustaine, Didier A.

    2015-12-01

    INCA-Indoor, a new indoor air quality (IAQ) model, has been developed to simulate the concentrations of volatile organic compounds (VOC) and oxidants considering indoor air specific processes such as: emission, ventilation, surface interactions (sorption, deposition, uptake). Based on the detailed version of SAPRC-07 chemical mechanism, INCA-Indoor is able to analyze the contribution of the production and loss pathways of key chemical species (VOCs, oxidants, radical species). The potential of this model has been tested through three complementary analyses: a comparison with the most detailed IAQ model found in the literature, focusing on oxidant species; realistic scenarios covering a large range of conditions, involving variable OH sources like HONO; and the investigation of alkenes ozonolysis under a large range of indoor conditions that can increase OH and HO2 concentrations. Simulations have been run changing nitrous acid (HONO) concentrations, NOx levels, photolysis rates and ventilation rates, showing that HONO can be the main source of indoor OH. Cleaning events using products containing D-limonene have been simulated at different periods of the day. These scenarios show that HOX concentrations can significantly increase in specific conditions. An assessment of the impact of indoor chemistry on the potential formation of secondary species such as formaldehyde (HCHO) and acetaldehyde (CH3CHO) has been carried out under various room configuration scenarios and a study of the HOx budget for different realistic scenarios has been performed. It has been shown that, under the simulation conditions, formaldehyde can be affected by oxidant concentrations via chemical production which can account for more than 10% of the total production, representing 6.5 ppb/h. On the other hand, acetaldehyde production is affected more by oxidation processes. When the photolysis rates are high, chemical processes are responsible for about 50% of the total production of

  19. Indoor Chemistry: Materials, Ventilation Systems, and Occupant Activities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morrison, G.C.; Corsi, R.L.; Destaillats, H.

    2006-05-01

    Chemical processes taking place in indoor environments can significantly alter the nature and concentrations of pollutants. Exposure to secondary contaminants generated in these reactions needs to be evaluated in association with many aspects of buildings to minimize their impact on occupant health and well-being. Focusing on indoor ozone chemistry, we describe alternatives for improving indoor air quality by controlling chemical changes related to building materials, ventilation systems, and occupant activities.

  20. Development of a modeling approach to estimate indoor-to-outdoor sulfur ratios and predict indoor PM2.5 and black carbon concentrations for Eastern Massachusetts households

    PubMed Central

    Tang, Chia Hsi; Garshick, Eric; Grady, Stephanie; Coull, Brent; Schwartz, Joel; Koutrakis, Petros

    2018-01-01

    The effects of indoor air pollution on human health have drawn increasing attention among the scientific community as individuals spend most of their time indoors. However, indoor air sampling is labor-intensive and costly, which limits the ability to study the adverse health effects related to indoor air pollutants. To overcome this challenge, many researchers have attempted to predict indoor exposures based on outdoor pollutant concentrations, home characteristics, and weather parameters. Typically, these models require knowledge of the infiltration factor, which indicates the fraction of ambient particles that penetrates indoors. For estimating indoor fine particulate matter (PM2.5) exposure, a common approach is to use the indoor-to-outdoor sulfur ratio (Sindoor/Soutdoor) as a proxy of the infiltration factor. The objective of this study was to develop a robust model that estimates Sindoor/Soutdoor for individual households that can be incorporated into models to predict indoor PM2.5 and black carbon (BC) concentrations. Overall, our model adequately estimated Sindoor/Soutdoor with an out-of-sample by home-season R2 of 0.89. Estimated Sindoor/Soutdoor reflected behaviors that influence particle infiltration, including window opening, use of forced air heating, and air purifier. Sulfur ratio-adjusted models predicted indoor PM2.5 and BC with high precision, with out-of-sample R2 values of 0.79 and 0.76, respectively. PMID:29064481

  1. Plils: A Practical Indoor Localization System through Less Expensive Wireless Chips via Subregion Clustering

    PubMed Central

    Cai, Jun; Deng, Yun; Yang, Junfeng; Zhou, Xinmin; Tan, Lina

    2018-01-01

    Reducing costs is a pragmatic method for promoting the widespread usage of indoor localization technology. Conventional indoor localization systems (ILSs) exploit relatively expensive wireless chips to measure received signal strength for positioning. Our work is based on a cheap and widely-used commercial off-the-shelf (COTS) wireless chip, i.e., the Nordic Semiconductor nRF24LE1, which has only several output power levels, and proposes a new power level based-ILS, called Plils. The localization procedure incorporates two phases: an offline training phase and an online localization phase. In the offline training phase, a self-organizing map (SOM) is utilized for dividing a target area into k subregions, wherein their grids in the same subregion have similar fingerprints. In the online localization phase, the support vector machine (SVM) and back propagation (BP) neural network methods are adopted to identify which subregion a tagged object is located in, and calculate its exact location, respectively. The reasonable value for k has been discussed as well. Our experiments show that Plils achieves 75 cm accuracy on average, and is robust to indoor obstacles. PMID:29329226

  2. Influence of ambient (outdoor) sources on residential indoor and personal PM2.5 concentrations: analyses of RIOPA data.

    PubMed

    Meng, Qing Yu; Turpin, Barbara J; Korn, Leo; Weisel, Clifford P; Morandi, Maria; Colome, Steven; Zhang, Junfeng Jim; Stock, Thomas; Spektor, Dalia; Winer, Arthur; Zhang, Lin; Lee, Jong Hoon; Giovanetti, Robert; Cui, William; Kwon, Jaymin; Alimokhtari, Shahnaz; Shendell, Derek; Jones, Jennifer; Farrar, Corice; Maberti, Silvia

    2005-01-01

    The Relationship of Indoor, Outdoor and Personal Air (RIOPA) study was designed to investigate residential indoor, outdoor and personal exposures to several classes of air pollutants, including volatile organic compounds, carbonyls and fine particles (PM2.5). Samples were collected from summer, 1999 to spring, 2001 in Houston (TX), Los Angeles (CA) and Elizabeth (NJ). Indoor, outdoor and personal PM2.5 samples were collected at 212 nonsmoking residences, 162 of which were sampled twice. Some homes were chosen due to close proximity to ambient sources of one or more target analytes, while others were farther from sources. Median indoor, outdoor and personal PM2.5 mass concentrations for these three sites were 14.4, 15.5 and 31.4 microg/m3, respectively. The contributions of ambient (outdoor) and nonambient sources to indoor and personal concentrations were quantified using a single compartment box model with measured air exchange rate and a random component superposition (RCS) statistical model. The median contribution of ambient sources to indoor PM2.5 concentrations using the mass balance approach was estimated to be 56% for all study homes (63%, 52% and 33% for California, New Jersey and Texas study homes, respectively). Reasonable variations in model assumptions alter median ambient contributions by less than 20%. The mean of the distribution of ambient contributions across study homes agreed well for the mass balance and RCS models, but the distribution was somewhat broader when calculated using the mass balance model with measured air exchange rates.

  3. Phthalate esters (PAEs) in indoor PM10/PM2.5 and human exposure to PAEs via inhalation of indoor air in Tianjin, China

    NASA Astrophysics Data System (ADS)

    Zhang, Leibo; Wang, Fumei; Ji, Yaqin; Jiao, Jiao; Zou, Dekun; Liu, Lingling; Shan, Chunyan; Bai, Zhipeng; Sun, Zengrong

    2014-03-01

    In this study, filter samples of six Phthalate esters (PAEs) in indoor PM10 and PM2.5 were collected from thirteen homes in Tianjin, China. The results showed that the concentrations of Σ6PAEs in indoor PM10 and PM2.5 were in the range of 13.878-1591.277 ng m-3 and 7.266-1244.178 ng m-3, respectively. Dibutyl phthalate (DBP) was the most abundant compounds followed by di-2-ethylhexyl phthalate (DEHP) in indoor PM10 and PM2.5. Whereas DBP and dimethyl phthalate (DMP) were the predominant compounds in indoor air (gas-phase + particle-phase), the median values were 573.467 and 368.364 ng m-3 respectively. The earlier construction time, the lesser indoor area, the old decoration, the very crowded items coated with plastic and a lower frequency of dusting may lead to a higher level of PAEs in indoor environment. The six PAEs in indoor PM10 and PM2.5 were higher in summer than those in winter. The daily intake (DI) of six PAEs for five age groups through air inhalation in indoor air in Tianjin was estimated. The results indicated that the highest exposure dose was DBP in every age group, and infants experienced the highest total DIs (median: 664.332 ng kg-bw-1 day-1) to ∑6PAEs, whereas adults experienced the lowest total DIs (median: 155.850 ng kg-bw-1 day-1) to ∑6PAEs. So, more attention should be paid on infants in the aspect of indoor inhalation exposure to PAEs.

  4. ENVIRONMENTAL TECHNOLOGY VERIFICATION FOR INDOOR AIR PRODUCTS

    EPA Science Inventory

    The paper discusses environmental technology verification (ETV) for indoor air products. RTI is developing the framework for a verification testing program for indoor air products, as part of EPA's ETV program. RTI is establishing test protocols for products that fit into three...

  5. Health and economic benefits of building ventilation interventions for reducing indoor PM2.5 exposure from both indoor and outdoor origins in urban Beijing, China.

    PubMed

    Yuan, Ye; Luo, Zhiwen; Liu, Jing; Wang, Yaowu; Lin, Yaoyu

    2018-06-01

    China is confronted with serious PM 2.5 pollution, especially in the capital city of Beijing. Exposure to PM 2.5 could lead to various negative health impacts including premature mortality. As people spend most of their time indoors, the indoor exposure to PM 2.5 from both indoor and outdoor origins constitutes the majority of personal exposure to PM 2.5 pollution. Different building interventions have been introduced to mitigate indoor PM 2.5 exposure, but always at the cost of energy expenditure. In this study, the health and economic benefits of different ventilation intervention strategies for reducing indoor PM 2.5 exposure are modeled using a representative urban residence in Beijing, with consideration of different indoor PM 2.5 emission strengths and outdoor pollution. Our modeling results show that the increase of envelope air-tightness can achieve significant economic benefits when indoor PM 2.5 emissions are absent; however, if an indoor PM 2.5 source is present, the benefits only increase slightly in mechanically ventilated buildings, but may show negative benefit without mechanical ventilation. Installing mechanical ventilation in Beijing can achieve annual economic benefits ranging from 200yuan/capita to 800yuan/capita if indoor PM 2.5 sources exist. If there is no indoor emission, the annual benefits above 200yuan/capita can be achieved only when the PM 2.5 filtration efficiency is no <90% and the envelope air-tightness is above Chinese National Standard Level 7. Introducing mechanical ventilation with low PM 2.5 filtration efficiency to current residences in urban Beijing will increase the indoor PM 2.5 exposure and result in excess costs to the residents. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Health effects of indoor odorants.

    PubMed Central

    Cone, J E; Shusterman, D

    1991-01-01

    People assess the quality of the air indoors primarily on the basis of its odors and on their perception of associated health risk. The major current contributors to indoor odorants are human occupant odors (body odor), environmental tobacco smoke, volatile building materials, bio-odorants (particularly mold and animal-derived materials), air fresheners, deodorants, and perfumes. These are most often present as complex mixtures, making measurement of the total odorant problem difficult. There is no current method of measuring human body odor, other than by human panel studies of expert judges of air quality. Human body odors have been quantitated in terms of the "olf" which is the amount of air pollution produced by the average person. Another quantitative unit of odorants is the "decipol," which is the perceived level of pollution produced by the average human ventilated by 10 L/sec of unpolluted air or its equivalent level of dissatisfaction from nonhuman air pollutants. The standard regulatory approach, focusing on individual constituents or chemicals, is not likely to be successful in adequately controlling odorants in indoor air. Besides the current approach of setting minimum ventilation standards to prevent health effects due to indoor air pollution, a standard based on the olf or decipol unit might be more efficacious as well as simpler to measure. PMID:1821378

  7. Concentrations and variability of organophosphate esters, halogenated flame retardants, and polybrominated diphenyl ethers in indoor and outdoor air in Stockholm, Sweden.

    PubMed

    Wong, Fiona; de Wit, Cynthia A; Newton, Seth R

    2018-05-10

    We investigated the concentrations and temporal variability of organophospate esters (OPEs), halogenated flame retardants (HFRs) and polybrominated diphenyl ethers (PBDEs) in indoor and outdoor urban air in Stockholm, Sweden over one year (2014-2015) period. The median concentrations of the three target chemical groups (OPEs, HFRs, PBDEs) were 1-2 orders of magnitude higher in indoor air than outdoor urban air. OPEs were the most abundant target FRs with median concentrations in indoor (Σ 10 OPE = 340 000 pg/m 3 ) and outdoor urban (Σ 10 OPEs = 3100 pg/m 3 ) air, being 3 orders of magnitude greater than for HFRs in indoor (Σ 15 HFRs = 120 pg/m 3 ) and outdoor urban (Σ 15 HFRs = 1.6 pg/m 3 ) air. In indoor air, PBDE concentrations (Σ 17 PBDEs = 33 pg/m 3 ) were lower than for the HFRs, but in outdoor urban air, concentrations (Σ 17 PBDEs = 1.1 pg/m 3 ) were similar to HFRs. The most abundant OPEs in both the indoor and outdoor urban air were tris(2-butoxyethyl)phosphate (TBOEP), tris(chloroisopropyl)phosphate (TCIPP), tris(2-chloroethyl)phosphate (TCEP), tri-n-butyl-phosphate (TnBP), triphenyl phosphate (TPhP) and tris(1,3-dichloroisopropyl)phosphate (TDCIPP). TCIPP in indoor air was found in the highest concentrations and showed the greatest temporal variability, which ranged from 85 000 to 1 900 000 pg/m 3 during the one-year sampling period. We speculate that activities in the building, e.g. floor cleaning, polishing, construction, introduction of new electronics and changes in ventilation rate could explain its variation. Some OPEs (TnBP, TCEP, TCIPP, TDCIPP and TPhP), HFRs/PBDEs (pentabromotoluene, 2, 3-dibromopropyl 2, 4, 6-tribromophenyl ether, hexabromobenzene, BDE-28, -47, and -99) in outdoor urban air showed seasonality, with increased concentrations during the warm period (p < 0.05, Pearson's r ranged from -0.45 to -0.91). The observed seasonality for OPEs was probably due to changes in primary

  8. Content analysis of Twitter chatter about indoor tanning.

    PubMed

    Waring, Molly E; Baker, Katie; Peluso, Anthony; May, Christine N; Pagoto, Sherry L

    2018-02-21

    Twitter may be useful for learning about indoor tanning behavior and attitudes. The objective of this study was to analyze the content of tweets about indoor tanning to determine the extent to which tweets are posted by people who tan, and to characterize the topics of tweets. We extracted 4,691 unique tweets from Twitter using the terms "tanning bed" or "tanning salon" over 7 days in March 2016. We content analyzed a random selection of 1,000 tweets, double-coding 20% of tweets (κ = 0.74, 81% agreement). Most tweets (71%) were by tanners (n = 699 individuals) and included tweets expressing positive sentiment about tanning (57%), and reports of a negative tanning experience (17%), burning (15%), or sleeping in a tanning bed (9%). Four percent of tweets were by tanning salon employees. Tweets posted by people unlikely to be tanners (15%) included tweets mocking tanners (71%) and health warnings (29%). The term "tanning bed" had higher precision for identifying individuals who engage in indoor tanning than "tanning salon"; 77% versus 45% of tweets captured by these search terms were by individuals who engaged in indoor tanning, respectively. Extrapolating to the full data set of 4,691 tweets, findings suggest that an average of 468 individuals who engage in indoor tanning can be identified by their tweets per day. The majority of tweets were from tanners and included reports of especially risky habits (e.g., burning, falling asleep). Twitter provides opportunity to identify indoor tanners and examine conversations about indoor tanning.

  9. Human Occupancy as a Source of Indoor Airborne Bacteria

    PubMed Central

    Hospodsky, Denina; Qian, Jing; Nazaroff, William W.; Yamamoto, Naomichi; Bibby, Kyle; Rismani-Yazdi, Hamid; Peccia, Jordan

    2012-01-01

    Exposure to specific airborne bacteria indoors is linked to infectious and noninfectious adverse health outcomes. However, the sources and origins of bacteria suspended in indoor air are not well understood. This study presents evidence for elevated concentrations of indoor airborne bacteria due to human occupancy, and investigates the sources of these bacteria. Samples were collected in a university classroom while occupied and when vacant. The total particle mass concentration, bacterial genome concentration, and bacterial phylogenetic populations were characterized in indoor, outdoor, and ventilation duct supply air, as well as in the dust of ventilation system filters and in floor dust. Occupancy increased the total aerosol mass and bacterial genome concentration in indoor air PM10 and PM2.5 size fractions, with an increase of nearly two orders of magnitude in airborne bacterial genome concentration in PM10. On a per mass basis, floor dust was enriched in bacterial genomes compared to airborne particles. Quantitative comparisons between bacterial populations in indoor air and potential sources suggest that resuspended floor dust is an important contributor to bacterial aerosol populations during occupancy. Experiments that controlled for resuspension from the floor implies that direct human shedding may also significantly impact the concentration of indoor airborne particles. The high content of bacteria specific to the skin, nostrils, and hair of humans found in indoor air and in floor dust indicates that floors are an important reservoir of human-associated bacteria, and that the direct particle shedding of desquamated skin cells and their subsequent resuspension strongly influenced the airborne bacteria population structure in this human-occupied environment. Inhalation exposure to microbes shed by other current or previous human occupants may occur in communal indoor environments. PMID:22529946

  10. A Breath of Fresh Air: Addressing Indoor Air Quality

    ERIC Educational Resources Information Center

    Palliser, Janna

    2011-01-01

    Indoor air pollution refers to "chemical, biological, and physical contamination of indoor air," which may result in adverse health effects (OECD 2003). The causes, sources, and types of indoor air pollutants will be addressed in this article, as well as health effects and how to reduce exposure. Learning more about potential pollutants in home…

  11. How Much Does Malaria Vector Control Quality Matter: The Epidemiological Impact of Holed Nets and Inadequate Indoor Residual Spraying

    PubMed Central

    Rehman, Andrea M.; Coleman, Mike; Schwabe, Christopher; Baltazar, Giovanna; Matias, Abrahan; Roncon Gomes, Irina; Yellott, Lee; Aragon, Cynthia; Nseng Nchama, Gloria; Mzilahowa, Themba; Rowland, Mark; Kleinschmidt, Immo

    2011-01-01

    Background Insecticide treated nets (ITN) and indoor residual spraying (IRS) are the two pillars of malaria vector control in Africa, but both interventions are beset by quality and coverage concerns. Data from three control programs were used to investigate the impact of: 1) the physical deterioration of ITNs, and 2) inadequate IRS spray coverage, on their respective protective effectiveness. Methods Malaria indicator surveys were carried out in 2009 and 2010 in Bioko Island, mainland Equatorial Guinea and Malawi to monitor infection with P.falciparum in children, mosquito net use, net condition and spray status of houses. Nets were classified by their condition. The association between infection and quality and coverage of interventions was investigated. Results There was reduced odds of infection with P.falciparum in children sleeping under ITNs that were intact (Odds ratio (OR): 0.65, 95% CI: 0.55–0.77 and OR: 0.81, 95% CI: 0.56–1.18 in Equatorial Guinea and in Malawi respectively), but the protective effect became less with increasingly worse condition of the net. There was evidence for a linear trend in infection per category increase in deterioration of nets. In Equatorial Guinea IRS offered protection to those in sprayed and unsprayed houses alike when neighbourhood spray coverage was high (≥80%) compared to those living in areas of low IRS coverage (<20%), regardless of whether the house they lived in was sprayed or not (adjusted OR = 0.54, 95% CI 0.33–0.89). ITNs provided only personal protection, offering no protection to non users. Although similar effects were seen in Malawi, the evidence was much weaker than in Equatorial Guinea. Conclusions Universal coverage strategies should consider policies for repair and replacement of holed nets and promote the care of nets by their owners. IRS programs should ensure high spray coverage since inadequate coverage gives little or no protection at all. PMID:21559436

  12. Assessment of indoor air problems at work with a questionnaire

    PubMed Central

    Reijula, K; Sundman-Digert, C

    2004-01-01

    Aims: To assess the extent of indoor air problems in office environments in Finland. Methods: Complaints and symptoms related to the indoor environment experienced by office workers were collected from 122 workplaces in 1996–99 by using the modified Indoor Air Questionnaire established by the Finnish Institute of Occupational Health. Altogether 11 154 employees took part in the survey. Results: The most common problems were dry air (35% of the respondents), stuffy air (34%), dust or dirt in the indoor environment (25%), and draught (22%). The most common work related symptoms were irritated, stuffy, or runny nose (20%), itching, burning, or irritation of the eyes (17%), and fatigue (16%). Women reported indoor air problems and work related symptoms more often than men. Allergic persons and smokers reported indoor air problems more often, and experienced work related symptoms more often than non-allergic persons and non-smokers. Conclusions: The complaints and work related symptoms associated with indoor air problems were common in office workers. The present questionnaire is a suitable tool for the occupational health personnel in investigating indoor air problems and the data of the survey can be used as a reference when the results of a survey at work are being analysed. PMID:14691270

  13. A simulation model of building intervention impacts on indoor environmental quality, pediatric asthma, and costs.

    PubMed

    Fabian, Maria Patricia; Adamkiewicz, Gary; Stout, Natasha Kay; Sandel, Megan; Levy, Jonathan Ian

    2014-01-01

    Although indoor environmental conditions can affect pediatric asthmatic patients, few studies have characterized the effect of building interventions on asthma-related outcomes. Simulation models can evaluate such complex systems but have not been applied in this context. We sought to evaluate the impact of building interventions on indoor environmental quality and pediatric asthma health care use, and to conduct cost comparisons between intervention and health care costs and energy savings. We applied our previously developed discrete event simulation model (DEM) to simulate the effect of environmental factors, medication compliance, seasonality, and medical history on (1) pollutant concentrations indoors and (2) asthma outcomes in low-income multifamily housing. We estimated health care use and costs at baseline and subsequent to interventions, and then compared health care costs with energy savings and intervention costs. Interventions, such as integrated pest management and repairing kitchen exhaust fans, led to 7% to 12% reductions in serious asthma events with 1- to 3-year payback periods. Weatherization efforts targeted solely toward tightening a building envelope led to 20% more serious asthma events, but bundling with repairing kitchen exhaust fans and eliminating indoor sources (eg, gas stoves or smokers) mitigated this effect. Our pediatric asthma model provides a tool to prioritize individual and bundled building interventions based on their effects on health and costs, highlighting the tradeoffs between weatherization, indoor air quality, and health. Our work bridges the gap between clinical and environmental health sciences by increasing physicians' understanding of the effect that home environmental changes can have on their patients' asthma. Copyright © 2013 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All rights reserved.

  14. Material Utilization of Organic Residues.

    PubMed

    Peinemann, Jan Christoph; Pleissner, Daniel

    2018-02-01

    Each year, 1.3 billion tons of food waste is generated globally. This waste traces back to industrial and agricultural producers, bakeries, restaurants, and households. Furthermore, lignocellulosic materials, including grass clippings, leaves, bushes, shrubs, and woods, appear in large amounts. Depending on the region, organic waste is either composted, burned directly, or converted into biogas. All of the options set aside the fact that organic residues are valuable resources containing carbohydrates, lipids, proteins, and phosphorus. Firstly, it is clear that avoidance of organic residues is imperative. However, the residues that accumulate nonetheless should be utilized by material means before energy production is targeted. This review presents different processes for the microbial utilization of organic residues towards compounds that are of great importance for the bioeconomy. The focus thereby is on the challenges coming along with downstream processing when the utilization of organic residues is carried out decentralized. Furthermore, a future process for producing lactic acid from organic residues is sketched.

  15. WSN based indoor air quality monitoring in classrooms

    NASA Astrophysics Data System (ADS)

    Wang, S. K.; Chew, S. P.; Jusoh, M. T.; Khairunissa, A.; Leong, K. Y.; Azid, A. A.

    2017-03-01

    Indoor air quality monitoring is essential as the human health is directly affected by indoor air quality. This paper presents the investigations of the impact of undergraduate students' concentration during lecture due to the indoor air quality in classroom. Three environmental parameters such as temperature, relative humidity and concentration of carbon dioxide are measured using wireless sensor network based air quality monitoring system. This simple yet reliable system is incorporated with DHT-11 and MG-811 sensors. Two classrooms were selected to install the monitoring system. The level of indoor air quality were measured and students' concentration was assessed using intelligent test during normal lecturing section. The test showed significant correlation between the collected environmental parameters and the students' level of performances in their study.

  16. Image-Based Localization for Indoor Environment Using Mobile Phone

    NASA Astrophysics Data System (ADS)

    Huang, Y.; Wang, H.; Zhan, K.; Zhao, J.; Gui, P.; Feng, T.

    2015-05-01

    Real-time indoor localization based on supporting infrastructures like wireless devices and QR codes are usually costly and labor intensive to implement. In this study, we explored a cheap alternative approach based on images for indoor localization. A user can localize him/herself by just shooting a photo of the surrounding indoor environment using the mobile phone. No any other equipment is required. This is achieved by employing image-matching and searching techniques with a dataset of pre-captured indoor images. In the beginning, a database of structured images of the indoor environment is constructed by using image matching and the bundle adjustment algorithm. Then each image's relative pose (its position and orientation) is estimated and the semantic locations of images are tagged. A user's location can then be determined by comparing a photo taken by the mobile phone to the database. This is done by combining quick image searching, matching and the relative orientation. This study also try to explore image acquisition plans and the processing capacity of off-the-shell mobile phones. During the whole pipeline, a collection of indoor images with both rich and poor textures are examined. Several feature detectors are used and compared. Pre-processing of complex indoor photo is also implemented on the mobile phone. The preliminary experimental results prove the feasibility of this method. In the future, we are trying to raise the efficiency of matching between indoor images and explore the fast 4G wireless communication to ensure the speed and accuracy of the localization based on a client-server framework.

  17. Current implications of past DDT indoor spraying in Oman.

    PubMed

    Booij, Petra; Holoubek, Ivan; Klánová, Jana; Kohoutek, Jiří; Dvorská, Alice; Magulová, Katarína; Al-Zadjali, Said; Čupr, Pavel

    2016-04-15

    In Oman, DDT was sprayed indoors during an intensive malaria eradication program between 1976 and 1992. DDT can remain for years after spraying and is associated with potential health risk. This raises the concern for human exposure in areas where DDT was used for indoor spraying. Twelve houses in three regions with a different history of DDT indoor spraying were chosen for a sampling campaign in 2005 to determine p,p'-dichlorodiphenyltrichloroethane (p,p'-DDT), p,p'-dichlorodiphenyldichloroethylene (p,p'-DDE) and p,p'-dichlorodiphenyldichloroethane (p,p'-DDD) levels in indoor air, dust, and outdoor soil. Although DDT was only sprayed indoor, p,p'-DDT, p,p'-DDE and p,p'-DDD were also found in outdoor soil. The results indicate that release and exposure continue for years after cessation of spraying. The predicted cancer risk based on concentrations determined in 2005, indicate that there was still a significant cancer risk up to 13 to 16years after indoor DDT spraying. A novel approach, based on region-specific half-lives, was used to predict concentrations in 2015 and showed that more than 21years after spraying, cancer risk for exposure to indoor air, dust, and outdoor soil are acceptable in Oman for adults and young children. The model can be used for other locations and countries to predict prospective exposure of contaminants based on indoor experimental measurements and knowledge about the spraying time-schedule to extrapolate region-specific half-lives and predict effects on the human population years after spraying. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Indoor Air Quality and Asthma

    PubMed Central

    Holm, Stewart

    2017-01-01

    Numerous contaminants in indoor air and their potential to cause or exacerbate asthma continue to be a subject of public health concern. Many agents are causally associated with or can exacerbate asthma, particularly in children. For formaldehyde, an established respiratory irritant based on numerous studies, the evidence for an association with asthma is still considered only limited or suggestive. However, there is no evidence that indicates increased sensitivity to sensory irritation to formaldehyde in people often regarded as susceptible such as asthmatics. Acrolein, but not formaldehyde, was significantly associated with asthma in a large cohort of children. This prompted an evaluation of this highly irritating chemical that had never previously been considered in the context of the indoor air/childhood asthma issue. Because acrolein is more potent than formaldehyde as a respiratory irritant and ubiquitous in indoor air, it is plausible that previous studies on potential risk factors and childhood asthma may be confounded by formaldehyde acting as an unrecognized proxy for acrolein. PMID:28250718

  19. An Intervention to Decrease Adolescent Indoor Tanning: A Multi-Method Pilot Study

    PubMed Central

    Lazovich, DeAnn; Choi, Kelvin; Rolnick, Cheri; Jackson, Jody M.; Forster, Jean; Southwell, Brian

    2013-01-01

    Purpose Indoor tanning usually begins during adolescence, but few strategies exist to discourage adolescent use. We developed and tested a parent–teenager intervention to decrease indoor tanning use. Methods Through focus groups, we identified key messages to enhance parent–teenager communication about indoor tanning, and then developed a pamphlet for parents and postcards for adolescents to use in a direct mail experiment with randomly selected households. Two weeks after the mailing, we asked intervention parents (n = 87) and adolescents (n = 69) and nonintervention parents (n = 31) and adolescents (n = 28) about intervention receipt and content recall, parental concern, monitoring, parent–teenager conversations, and indoor tanning intention. Results In intervention households, 54% of mothers and 56% of girls recalled receipt and reported reading materials, but few boys and no fathers did. Among mothers, 57% in intervention households indicated concern about daughters’ indoor tanning, and 25% would allow daughters to tan indoors, whereas 43% of nonintervention mothers had concerns and 46% would allow indoor tanning. Fewer girls in intervention households than in nonintervention households thought parents would allow indoor tanning (44% vs. 65%), and fewer intended to tan indoors (36% vs. 60%). Most mothers and daughters who read the intervention materials also reported discussions about indoor tanning. Moreover, the less likely girls were to think that their mothers would allow indoor tanning, the less likely it was that they intended to tan indoors, a relationship mediated by perceptions of maternal monitoring. Conclusions A systematic qualitative and quantitative research approach yielded well-received indoor tanning prevention messages for mothers and female adolescents. Enhancing maternal monitoring has potential to decrease adolescent indoor tanning. PMID:23601614

  20. Integrated WiFi/PDR/Smartphone Using an Unscented Kalman Filter Algorithm for 3D Indoor Localization.

    PubMed

    Chen, Guoliang; Meng, Xiaolin; Wang, Yunjia; Zhang, Yanzhe; Tian, Peng; Yang, Huachao

    2015-09-23

    Because of the high calculation cost and poor performance of a traditional planar map when dealing with complicated indoor geographic information, a WiFi fingerprint indoor positioning system cannot be widely employed on a smartphone platform. By making full use of the hardware sensors embedded in the smartphone, this study proposes an integrated approach to a three-dimensional (3D) indoor positioning system. First, an improved K-means clustering method is adopted to reduce the fingerprint database retrieval time and enhance positioning efficiency. Next, with the mobile phone's acceleration sensor, a new step counting method based on auto-correlation analysis is proposed to achieve cell phone inertial navigation positioning. Furthermore, the integration of WiFi positioning with Pedestrian Dead Reckoning (PDR) obtains higher positional accuracy with the help of the Unscented Kalman Filter algorithm. Finally, a hybrid 3D positioning system based on Unity 3D, which can carry out real-time positioning for targets in 3D scenes, is designed for the fluent operation of mobile terminals.

  1. Integrated WiFi/PDR/Smartphone Using an Unscented Kalman Filter Algorithm for 3D Indoor Localization

    PubMed Central

    Chen, Guoliang; Meng, Xiaolin; Wang, Yunjia; Zhang, Yanzhe; Tian, Peng; Yang, Huachao

    2015-01-01

    Because of the high calculation cost and poor performance of a traditional planar map when dealing with complicated indoor geographic information, a WiFi fingerprint indoor positioning system cannot be widely employed on a smartphone platform. By making full use of the hardware sensors embedded in the smartphone, this study proposes an integrated approach to a three-dimensional (3D) indoor positioning system. First, an improved K-means clustering method is adopted to reduce the fingerprint database retrieval time and enhance positioning efficiency. Next, with the mobile phone’s acceleration sensor, a new step counting method based on auto-correlation analysis is proposed to achieve cell phone inertial navigation positioning. Furthermore, the integration of WiFi positioning with Pedestrian Dead Reckoning (PDR) obtains higher positional accuracy with the help of the Unscented Kalman Filter algorithm. Finally, a hybrid 3D positioning system based on Unity 3D, which can carry out real-time positioning for targets in 3D scenes, is designed for the fluent operation of mobile terminals. PMID:26404314

  2. Low-cost interventions improve indoor air quality and children's health.

    PubMed

    Johnson, Linda; Ciaccio, Christina; Barnes, Charles S; Kennedy, Kevin; Forrest, Erika; Gard, Luke C; Pacheco, Freddy; Dowling, Paul; Portnoy, Jay M

    2009-01-01

    Intervention in the home environment to reduce asthma triggers theoretically improves health outcomes for asthmatic children. Practical benefit from application of these interventions has proven difficult. This single-blind study tested the effectiveness of simple low-cost home interventions in improving health scores of children with asthma. Families with at least one asthmatic child were recruited. Initial health examination, health, and home assessments were conducted and targeted interventions were implemented. Interventions included dehumidification, air filtration, furnace servicing, and high-efficiency furnace filters. When present, gross fungal contamination was remediated. Asthma education was provided along with education in healthy home practices. Follow-up assessments were conducted after 6 months. Health surveys were completed at enrollment and follow-up. This study enrolled 219 children with asthma. Home inspections and interventions were conducted in 181 homes and 83 families completed all phases. Reduction in asthma and allergy-related health scores was shown in follow-up health surveys. Health improvements were significant for cough when heating, ventilation, and air conditioning (HVAC) service and dehumidification were used. Breathing problems were significantly improved for dehumidification, HVAC service, and room air cleaners. Total dust allergen load was reduced for the dehumidification group (p < 0.05). Mold spore counts were reduced one order of magnitude in 25% of the homes. Indoor spore counts adjusted for outdoor spore levels were reduced overall (p < 0.01). Simple low-cost interventions directed to producing cleaner indoor air coupled with healthy home education improve the indoor air quality and health in asthmatic children.

  3. INDOOR FUNGAL CONTAMINANTS: ASSESSING THE ALLERGIC POTENTIAL

    EPA Science Inventory

    The indoor environment has increased in importance to children's health with children now spending more than 90% of their time indoors. Molds are an important component of this environment and have been associated with exacerbation of asthma as well as a number of other health e...

  4. Indoor Pollutants: Environmental Hazards to Young Children.

    ERIC Educational Resources Information Center

    Noyes, Dorothy

    1987-01-01

    Alerts parents, teachers, and others to some of the leading indoor environmental hazards to young children which are caused by various types of indoor pollutants: cigarette smoke; heating/cooking equipment; asbestos; pesticides; art supplies; radon; and lead. Also suggests ways to reduce these health hazards. (BB)

  5. EVALUATION OF AIR PURIFICATION DEVICES FOR CONTROL OF INDOOR PM

    EPA Science Inventory

    Because people spend most of their time indoors (89%), the indoor environment is a primary determinant of particle exposure. The indoor environment is especially an important determinant for the very young, the very old, and those with underlying cardiopulmonary disease because...

  6. CFD simulation research on residential indoor air quality.

    PubMed

    Yang, Li; Ye, Miao; He, Bao-Jie

    2014-02-15

    Nowadays people are excessively depending on air conditioning to create a comfortable indoor environment, but it could cause some health problems in a long run. In this paper, wind velocity field, temperature field and air age field in a bedroom with wall-hanging air conditioning running in summer are analyzed by CFD numerical simulation technology. The results show that wall-hanging air conditioning system can undertake indoor heat load and conduct good indoor thermal comfort. In terms of wind velocity, air speed in activity area where people sit and stand is moderate, most of which cannot feel wind flow and meet the summer indoor wind comfort requirement. However, for air quality, there are local areas without ventilation and toxic gases not discharged in time. Therefore it is necessary to take effective measures to improve air quality. Compared with the traditional measurement method, CFD software has many advantages in simulating indoor environment, so it is hopeful for humans to create a more comfortable, healthy living environment by CFD in the future. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Reactive indoor air chemistry and health-A workshop summary.

    PubMed

    Wells, J R; Schoemaecker, C; Carslaw, N; Waring, M S; Ham, J E; Nelissen, I; Wolkoff, P

    2017-11-01

    The chemical composition of indoor air changes due to the reactive nature of the indoor environment. Historically, only the stable parent compounds were investigated due to their ease of measurement by conventional methods. Today, however, scientists can better characterize oxidation products (gas and particulate-phase) formed by indoor chemistry. An understanding of occupant exposure can be developed through the investigation of indoor oxidants, the use of derivatization techniques, atmospheric pressure detection, the development of real-time technologies, and improved complex modeling techniques. Moreover, the connection between exposure and health effects is now receiving more attention from the research community. Nevertheless, a need still exists for improved understanding of the possible link between indoor air chemistry and observed acute or chronic health effects and long-term effects such as work-related asthma. Published by Elsevier GmbH.

  8. Concentrations of indoor pollutants database: User`s manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-05-01

    This manual describes the computer-based database on indoor air pollutants. This comprehensive database alloys helps utility personnel perform rapid searches on literature related to indoor air pollutants. Besides general information, it provides guidance for finding specific information on concentrations of indoor air pollutants. The manual includes information on installing and using the database as well as a tutorial to assist the user in becoming familiar with the procedures involved in doing bibliographic and summary section searches. The manual demonstrates how to search for information by going through a series of questions that provide search parameters such as pollutants type, year,more » building type, keywords (from a specific list), country, geographic region, author`s last name, and title. As more and more parameters are specified, the list of references found in the data search becomes smaller and more specific to the user`s needs. Appendixes list types of information that can be input into the database when making a request. The CIP database allows individual utilities to obtain information on indoor air quality based on building types and other factors in their own service territory. This information is useful for utilities with concerns about indoor air quality and the control of indoor air pollutants. The CIP database itself is distributed by the Electric Power Software Center and runs on IBM PC-compatible computers.« less

  9. Quantitative health impact of indoor radon in France.

    PubMed

    Ajrouche, Roula; Roudier, Candice; Cléro, Enora; Ielsch, Géraldine; Gay, Didier; Guillevic, Jérôme; Marant Micallef, Claire; Vacquier, Blandine; Le Tertre, Alain; Laurier, Dominique

    2018-05-08

    Radon is the second leading cause of lung cancer after smoking. Since the previous quantitative risk assessment of indoor radon conducted in France, input data have changed such as, estimates of indoor radon concentrations, lung cancer rates and the prevalence of tobacco consumption. The aim of this work was to update the risk assessment of lung cancer mortality attributable to indoor radon in France using recent risk models and data, improving the consideration of smoking, and providing results at a fine geographical scale. The data used were population data (2012), vital statistics on death from lung cancer (2008-2012), domestic radon exposure from a recent database that combines measurement results of indoor radon concentration and the geogenic radon potential map for France (2015), and smoking prevalence (2010). The risk model used was derived from a European epidemiological study, considering that lung cancer risk increased by 16% per 100 becquerels per cubic meter (Bq/m 3 ) indoor radon concentration. The estimated number of lung cancer deaths attributable to indoor radon exposure is about 3000 (1000; 5000), which corresponds to about 10% of all lung cancer deaths each year in France. About 33% of lung cancer deaths attributable to radon are due to exposure levels above 100 Bq/m 3 . Considering the combined effect of tobacco and radon, the study shows that 75% of estimated radon-attributable lung cancer deaths occur among current smokers, 20% among ex-smokers and 5% among never-smokers. It is concluded that the results of this study, which are based on precise estimates of indoor radon concentrations at finest geographical scale, can serve as a basis for defining French policy against radon risk.

  10. Indoor and Outdoor Play in Preschool Programs

    ERIC Educational Resources Information Center

    Kroeker, Julia

    2017-01-01

    The purpose of this study was to explain children's indoor and outdoor play in preschool programs in terms of teacher interaction, peer interaction and task orientation. Children's indoor and outdoor play behaviors were compared using the Individualized Classroom Assessment Scoring System (inCLASS). Findings included significant differences on…

  11. RISK ASSESSMENT/RISK MANAGEMENT FOR INDOOR MOLD

    EPA Science Inventory

    In 1998, a team of eight EPA researchers from NERL, NHEERL, NRMRL and NCEA organized to examine the role of indoor molds/fungi in children's health. The make-up of the indoor environment is critical to the health of children in general and has a particularly important influence ...

  12. Indoor air pollution: Acute adverse health effects and host susceptibility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zummo, S.M.; Karol, M.H.

    1996-01-01

    Increased awareness of the poor quality of indoor air compared with outdoor air has resulted in a significant amount of research on the adverse health effects and mechanisms of action of indoor air pollutants. Common indoor air agents are identified, along with resultant adverse health effects, mechanisms of action, and likely susceptible populations. Indoor air pollutants range from biological agents (such as dust mites) to chemical irritants (such as nitrogen dioxide, carbon monoxide, sulfur dioxide, formaldehyde, and isocyanates). These agents may exert their effects through allergic as well as nonallergic mechanisms. While the public does not generally perceive poor indoormore » air quality as a significant health risk, increasing reports of illness related to indoor air and an expanding base of knowledge on the health effects of indoor air pollution are likely to continue pushing the issue to the forefront.« less

  13. Clearing the Air: Asthma and Indoor Air Exposure (Highlights)

    EPA Pesticide Factsheets

    The National Academy of Sciences Institute of Medicine issued this report in 2000 describing the role of indoor environmental pollutants in the development and exacerbation of asthma. The report concludes that exposure to indoor pollutants is an important contributor to the asthma problem in this nation. Asthma sufferers should consult with their doctor about reducing their exposure indoor air pollutants.

  14. QUANTIFYING INDOOR MOLDS

    EPA Science Inventory

    There is growing awareness that indoor molds/fungi may be connected to such conditions as asthma, allergies, hemorrhaging, chronic rhinosinusitis, memory loss, and a symptom complex called sick-building-syndrome. In addition, molds cause frequently fatal nosocomical infections. ...

  15. Resurgence of Malaria Following Discontinuation of Indoor Residual Spraying of Insecticide in an Area of Uganda With Previously High-Transmission Intensity.

    PubMed

    Raouf, Saned; Mpimbaza, Arthur; Kigozi, Ruth; Sserwanga, Asadu; Rubahika, Denis; Katamba, Henry; Lindsay, Steve W; Kapella, Bryan K; Belay, Kassahun A; Kamya, Moses R; Staedke, Sarah G; Dorsey, Grant

    2017-08-01

    Indoor residual spraying (IRS) and long-lasting insecticidal nets (LLINs) are the primary tools for malaria prevention in Africa. It is not known whether reductions in malaria can be sustained after IRS is discontinued. Our aim in this study was to assess changes in malaria morbidity in an area of Uganda with historically high transmission where IRS was discontinued after a 4-year period followed by universal LLIN distribution. Individual-level malaria surveillance data were collected from 1 outpatient department and 1 inpatient setting in Apac District, Uganda, from July 2009 through November 2015. Rounds of IRS were delivered approximately every 6 months from February 2010 through May 2014 followed by universal LLIN distribution in June 2014. Temporal changes in the malaria test positivity rate (TPR) were estimated during and after IRS using interrupted time series analyses, controlling for age, rainfall, and autocorrelation. Data include 65 421 outpatient visits and 13 955 pediatric inpatient admissions for which a diagnostic test for malaria was performed. In outpatients aged <5 years, baseline TPR was 60%-80% followed by a rapid and then sustained decrease to 15%-30%. During the 4-18 months following discontinuation of IRS, absolute TPR values increased by an average of 3.29% per month (95% confidence interval, 2.01%-4.57%), returning to baseline levels. Similar trends were seen in outpatients aged ≥5 years and pediatric admissions. Discontinuation of IRS in an area with historically high transmission intensity was associated with a rapid increase in malaria morbidity to pre-IRS levels. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com

  16. Indoor air quality at nine shopping malls in Hong Kong.

    PubMed

    Li, W M; Lee, S C; Chan, L Y

    2001-06-12

    Hong Kong is one of the most attractive shopping paradises in the world. Many local people and international tourists favor to spend their time in shopping malls in Hong Kong. Good indoor air quality is, therefore, very essential to shoppers. In order to characterize the indoor air quality in shopping malls, nine shopping malls in Hong Kong were selected for this study. The indoor air pollutants included carbon dioxide (CO2), carbon monoxide (CO), total hydrocarbons (THC), formaldehyde (HCHO), respirable particulate matter (PM10) and total bacteria count (TBC). More than 40% of the shopping malls had 1-h average CO2 levels above the 1000 ppm of the ASHRAE standard on both weekdays and weekends. Also, they had average weekday PM10 concentrations that exceeded the Hong Kong Indoor Air Quality Objective (HKIAQO). The highest indoor PM10 level at a mall was 380 microg/m3. Of the malls surveyed, 30% had indoor airborne bacteria levels above 1000 cfu/m3 set by the HKIAQO. The elevated indoor CO2 and bacteria levels could result from high occupancy combined with insufficient ventilation. The increased PM10 levels could be probably attributed to illegal smoking inside these establishments. In comparison, the shopping malls that contained internal public transport drop-off areas, where vehicles were parked with idling engines and had major entry doors close to heavy traffic roads had higher CO and PM10 indoor levels. In addition, the extensive use of cooking stoves without adequate ventilation inside food courts could increase indoor CO2, CO and PM10 levels.

  17. Prevention of Residual Gas Condensation on the Laser Entry Hole Windows on Cryogenic NIF Targets Using a Protective Warm Film

    DOE PAGES

    Bhandarkar, Suhas; Fair, Jim; Haid, Ben; ...

    2018-01-19

    Many of the early cryogenic shots on NIF were plagued by buildup of considerable mass of extraneous ice on the LEH windows, a consequence of condensation of the residual air in the surrounding chamber. Thickness of this ice depended on the exact chamber pressure and the target fielding time duration, both extremely difficult to keep constant given the broad range of target types being shot. In this paper, we describe our work in designing a robust solution in the form of a second thin film that shielded the LEH window from the contaminating ice. Several detailed cryogenic considerations were requiredmore » to ensure the proper functioning of this new window, which were simulated and verified experimentally. Data from numerous subsequent shots showed marked improvement in performance, which made this new feature an essential component for all cryogenic NIF targets.« less

  18. Prevention of Residual Gas Condensation on the Laser Entry Hole Windows on Cryogenic NIF Targets Using a Protective Warm Film

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bhandarkar, Suhas; Fair, Jim; Haid, Ben

    Many of the early cryogenic shots on NIF were plagued by buildup of considerable mass of extraneous ice on the LEH windows, a consequence of condensation of the residual air in the surrounding chamber. Thickness of this ice depended on the exact chamber pressure and the target fielding time duration, both extremely difficult to keep constant given the broad range of target types being shot. In this paper, we describe our work in designing a robust solution in the form of a second thin film that shielded the LEH window from the contaminating ice. Several detailed cryogenic considerations were requiredmore » to ensure the proper functioning of this new window, which were simulated and verified experimentally. Data from numerous subsequent shots showed marked improvement in performance, which made this new feature an essential component for all cryogenic NIF targets.« less

  19. Indoor Air Quality Building Education and Assessment Model

    EPA Pesticide Factsheets

    The Indoor Air Quality Building Education and Assessment Model (I-BEAM), released in 2002, is a guidance tool designed for use by building professionals and others interested in indoor air quality in commercial buildings.

  20. Indoor and outdoor elemental mercury: a comparison of three different cases.

    PubMed

    Loupa, G; Polyzou, C; Zarogianni, A M; Ouzounis, K; Rapsomanikis, S

    2017-02-01

    Gaseous elemental mercury (GEM) concentrations were determined in three different indoor environments: an office in a building with no indoor sources of mercury (Bldg. I), an office affected by indoor mercury emissions from an adjacent laboratory (Bldg. II), and finally, an office where an outdoor mercury spill occurred accidentally (Bldg. III). The maximum recorded indoor GEM concentrations, with the largest variation in time, were observed in Bldg. II, with a continuous indoor mercury source (lower to upper quartile 15 to 62 ng m -3 ). The lowest values were recorded in Bldg. I (lower to upper quartile 3 to 5 ng m -3 ), where indoor GEM levels were affected mainly by the exhaust of vehicles in the parking lot of the building. The monitoring of GEM indoors (lower to upper quartile 15 to 42 ng m -3 ), and outdoors (in several heights) of the Bldg. III, revealed that the cleaning up procedure that followed the spill was not adequate. Auxiliary measurements in the first two cases were the indoor microclimatic conditions, as well as the indoor CO 2 concentrations, and in the third case the outdoor meteorological data. The exhaust of vehicles, the chemical reagents, and an outdoor mercury spill were found to mainly affect the observed indoor GEM levels. People in Bldg. II and people walking through the area, where Hg 0 was spilled, were found to be exposed to concentrations above some guide values.

  1. Reducing health risks from indoor exposures in rapidly developing urban China.

    PubMed

    Zhang, Yinping; Mo, Jinhan; Weschler, Charles J

    2013-07-01

    Over the past two decades there has been a large migration of China's population from rural to urban regions. At the same time, residences in cities have changed in character from single-story or low-rise buildings to high-rise structures constructed and furnished with many synthetic materials. As a consequence, indoor exposures (to pollutants with outdoor and indoor sources) have changed significantly. We briefly discuss the inferred impact that urbanization and modernization have had on indoor exposures and public health in China. We argue that growing adverse health costs associated with these changes are not inevitable, and we present steps that could be taken to reduce indoor exposures to harmful pollutants. As documented by China's Ministry of Health, there have been significant increases in morbidity and mortality among urban residents over the past 20 years. Evidence suggests that the population's exposure to air pollutants has contributed to increases in lung cancer, cardiovascular disease, pulmonary disease, and birth defects. Whether a pollutant has an outdoor or an indoor source, most exposure to the pollutant occurs indoors. Going forward, indoor exposures can be reduced by limiting the ingress of outdoor pollutants (while providing adequate ventilation with clean air), minimizing indoor sources of pollutants, updating government policies related to indoor pollution, and addressing indoor air quality during a building's initial design. Taking the suggested steps could lead to significant reductions in morbidity and mortality, greatly reducing the societal costs associated with pollutant derived ill health.

  2. Air-Sense: indoor environment monitoring evaluation system based on ZigBee network

    NASA Astrophysics Data System (ADS)

    Huang, Yang; Hu, Liang; Yang, Disheng; Liu, Hengchang

    2017-08-01

    In the modern life, people spend most of their time indoors. However, indoor environmental quality problems have always been affecting people’s social activities. In general, indoor environmental quality is also related to our indoor activities. Since most of the organic irritants and volatile gases are colorless, odorless and too tiny to be seen, because we have been unconsciously overlooked indoor environment quality. Consequently, our body suffer a great health problem. In this work, we propose Air-Sense system which utilizes the platform of ZigBee Network to collect and detect the real-time indoor environment quality. What’s more, Air-Sense system can also provide data analysis, and visualizing the results of the indoor environment to the user.

  3. Evaluating the Efficiency of Air Shower in Removing Lead from Army Combat Uniform Swatches Loaded with Gunshot Residue

    DTIC Science & Technology

    2016-03-25

    well-known toxicant and the exposure on indoor firing ranges presents a health risk to both range employees and shooters. Contaminated clothing... firing ranges have employed a new control – air shower (AS), although its effectiveness in this particular application has not been examined. The... firing lead- containing ammunition inside a sealed chamber and allowing the gunshot residue to settle on swatches placed inside the chamber. The

  4. Exploring the consequences of climate change for indoor air quality

    NASA Astrophysics Data System (ADS)

    Nazaroff, William W.

    2013-03-01

    Climate change will affect the concentrations of air pollutants in buildings. The resulting shifts in human exposure may influence public health. Changes can be anticipated because of altered outdoor pollution and also owing to changes in buildings effected in response to changing climate. Three classes of factors govern indoor pollutant levels in occupied spaces: (a) properties of pollutants; (b) building factors, such as the ventilation rate; and (c) occupant behavior. Diversity of indoor conditions influences the public health significance of climate change. Potentially vulnerable subpopulations include not only the young and the infirm but also those who lack resources to respond effectively to changing conditions. Indoor air pollutant levels reflect the sum of contributions from indoor sources and from outdoor pollutants that enter with ventilation air. Pollutant classes with important indoor sources include the byproducts of combustion, radon, and volatile and semivolatile organic compounds. Outdoor pollutants of special concern include particulate matter and ozone. To ensure good indoor air quality it is important first to avoid high indoor emission rates for all pollutants and second to ensure adequate ventilation. A third factor is the use of air filtration or air cleaning to achieve further improvements where warranted. Reprinted with permission from Climate Change, the Indoor Environment, and Health (2011) by the National Academy of Sciences, Courtesy of the National Academies Press, Washington, DC.

  5. Research on Vibration Test in Urban Indoor Substation

    NASA Astrophysics Data System (ADS)

    Ma, Yuchao; Mo, Juan; Xu, Jin; Fan, Baozhen

    2018-01-01

    The problem of vibration and noise of urban indoor substations has becoming more and more socially concerned.The urban indoor substation of 110kV and its conjoined buildings were taken as the research object and the vibration tests of the transformer and each floor slab were respectively carried out.The sound vibration characteristics and sound transmission rules of the urban indoor substation were obtained through the time-frequency analysis and coherence analysis of the test data. The vibration spectrum of transformer body was mainly 100Hz together with its multiplying factors and the vibration characteristics of the floor slab were basically the same as those of the transformer body. it is crucial to control the vibration and noise transmission in the equipment floor of the urban indoor substation.

  6. Controlling Pollutants and Sources: Indoor Air Quality Design Tools for Schools

    EPA Pesticide Factsheets

    To protect indoor environmental quality the designer should understand indoor air quality problems and seek to eliminate potential sources of contamination that originate from outdoors as well as indoors.

  7. Fluctuating residual limb volume accommodated with an adjustable, modular socket design: A novel case report.

    PubMed

    Mitton, Kay; Kulkarni, Jai; Dunn, Kenneth William; Ung, Anthony Hoang

    2017-10-01

    This novel case report describes the problems of prescribing a prosthetic socket in a left transfemoral amputee secondary to chronic patellofemoral instability compounded by complex regional pain syndrome. Case Description and Methods: Following the amputation, complex regional pain syndrome symptoms recurred in the residual limb, presenting mainly with oedema. Due to extreme daily volume fluctuations of the residual limb, a conventional, laminated thermoplastic socket fitting was not feasible. Findings and Outcomes: An adjustable, modular socket design was trialled. The residual limb volume fluctuations were accommodated within the socket. Amputee rehabilitation could be continued, and the rehabilitation goals were achieved. The patient was able to wear the prosthesis for 8 h daily and to walk unaided indoors and outdoors. An adjustable, modular socket design accommodated the daily residual limb volume fluctuations and provided a successful outcome in this case. It demonstrates the complexities of socket fitting and design with volume fluctuations. Clinical relevance Ongoing complex regional pain syndrome symptoms within the residual limb can lead to fitting difficulties in a conventional, laminated thermoplastic socket due to volume fluctuations. An adjustable, modular socket design can accommodate this and provide a successful outcome.

  8. Enhancing indoor air quality –The air filter advantage

    PubMed Central

    Vijayan, Vannan Kandi; Paramesh, Haralappa; Salvi, Sundeep Santosh; Dalal, Alpa Anil Kumar

    2015-01-01

    Air pollution has become the world's single biggest environmental health risk, linked to around 7 million deaths in 2012 according to a recent World Health Organisation (WHO) report. The new data further reveals a stronger link between, indoor and outdoor air pollution exposure and cardiovascular diseases, such as strokes and ischemic heart disease, as well as between air pollution and cancer. The role of air pollution in the development of respiratory diseases, including acute respiratory infections and chronic obstructive pulmonary diseases, is well known. While both indoor and outdoor pollution affect health, recent statistics on the impact of household indoor pollutants (HAP) is alarming. The WHO factsheet on HAP and health states that 3.8 million premature deaths annually - including stroke, ischemic heart disease, chronic obstructive pulmonary disease (COPD) and lung cancer are attributed to exposure to household air pollution. Use of air cleaners and filters are one of the suggested strategies to improve indoor air quality. This review discusses the impact of air pollutants with special focus on indoor air pollutants and the benefits of air filters in improving indoor air quality. PMID:26628762

  9. 9 CFR 3.2 - Indoor housing facilities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Transportation of Dogs and Cats 1 Facilities and Operating Standards § 3.2 Indoor housing facilities. (a) Heating, cooling, and temperature. Indoor housing facilities for dogs and cats must be sufficiently heated and cooled when necessary to protect the dogs and cats from temperature or humidity extremes and to provide...

  10. 9 CFR 3.2 - Indoor housing facilities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Transportation of Dogs and Cats 1 Facilities and Operating Standards § 3.2 Indoor housing facilities. (a) Heating, cooling, and temperature. Indoor housing facilities for dogs and cats must be sufficiently heated and cooled when necessary to protect the dogs and cats from temperature or humidity extremes and to provide...

  11. Seasonal and Spatial Variations of Indoor Pollen in a Hospital

    PubMed Central

    Tormo-Molina, Rafael; Gonzalo-Garijo, Ángela; Silva-Palacios, Inmaculada; Fernández-Rodríguez, Santiago

    2009-01-01

    The airborne indoor pollen in a hospital of Badajoz (Spain) was monitored over two years using a personal Burkard sampler. The air was sampled in four places indoors—one closed room and one open ward on each of the ground and the third floors—and one place outdoors at the entrance to the hospital. The results were compared with data from a continuous volumetric sampler. While 32 pollen types were identified, nearly 75% of the total counts were represented by just five of them. These were: Quercus, Cupressaceae, Poaceae, Olea, and Plantago. The average indoor concentration was 25.2 grains/m3, and the average indoor/outdoor ratio was 0.27. A strong seasonal pattern was found, with the highest levels in spring and winter, and the indoor concentrations were correlated with the outdoor one. Indoor air movement led to great homogeneity in the airborne pollen presence: the indoor results were not influenced by whether or not the room was isolated, the floor level, or the number of people in or transiting the site during sampling. The presence of ornamental vegetation in the area surrounding the building affected the indoor counts directly as sources of the pollen. PMID:20049254

  12. Indoor air quality in public utility environments-a review.

    PubMed

    Śmiełowska, Monika; Marć, Mariusz; Zabiegała, Bożena

    2017-04-01

    Indoor air quality has been the object of interest for scientists and specialists from the fields of science such as chemistry, medicine and ventilation system design. This results from a considerable number of potential factors, which may influence the quality of the broadly understood indoor air in a negative way. Poor quality of indoor air in various types of public utility buildings may significantly affect an increase in the incidence of various types of civilisation diseases. This paper presents information about a broad spectrum of chemical compounds that were identified and determined in the indoor environment of various types of public utility rooms such as churches, museums, libraries, temples and hospitals. An analysis of literature data allowed for identification of the most important transport paths of chemical compounds that significantly influence the quality of the indoor environment and thus the comfort of living and the health of persons staying in it.

  13. Assessment of Community Awareness and Practices Concerning Indoor Air Pollutants - Madison County, Alabama, June 2017.

    PubMed

    Siza, Charlene; Morrison, Melissa; Harris, Scott; Hatch, Timothy; Tyler, Michael

    2018-04-20

    The Alabama Department of Public Health (ADPH) conducts an annual community assessment to evaluate household preparedness and local public health concerns. In June 2017, ADPH conducted a Community Assessment for Public Health Emergency Response (CASPER), focusing on indoor air pollutants in seven neighborhoods in Madison County, Alabama, where a large percentage of homes were built before 1980. Local health partners had concerns about indoor air quality and environmental risks such as radon; however, limited information was available regarding community awareness, prevention, and mitigation measures related to potential exposures. Weighted response frequencies were calculated from assessment responses. Among 192 household interview respondents, 78.4% were aware of potential indoor lead exposures, but only 12.6% of respondents living in houses built before 1978 reported that the house had been tested for lead. Similarly, respondents in 70.2% of households had heard of radon; however, only 7.3% of houses had been tested for radon. Smoking was reported by residents of 45.7% of households; among those, 48.4% reported that smoking occurred inside the house. Identified gaps in exposure prevention and mitigation, including low lead and radon testing rates and a high prevalence of indoor smoking, were shared with the local health department, and recommendations for timely interventions and policy guidance (e.g., targeted education campaigns and smoking cessation programs) were presented. Results of this CASPER demonstrated its usefulness and efficiency in gathering community-level data to help guide public health policies and timely interventions.

  14. A reduction in malaria transmission intensity in Northern Ghana after 7 years of indoor residual spraying.

    PubMed

    Coleman, Sylvester; Dadzie, Samuel K; Seyoum, Aklilu; Yihdego, Yemane; Mumba, Peter; Dengela, Dereje; Ricks, Philip; George, Kristen; Fornadel, Christen; Szumlas, Daniel; Psychas, Paul; Williams, Jacob; Appawu, Maxwell A; Boakye, Daniel A

    2017-08-10

    Indoor residual spraying (IRS) is being implemented as one of the malaria prevention methods in the Northern Region of Ghana. Changes in longevity, sporozoite and entomological inoculation rates (EIRs) of major malaria vectors were monitored to assess the impact of IRS in selected districts. Monthly human landing catches (HLCs) were used to collect mosquitoes from sentinel sites in three adjacent districts between July 2009 and December 2014: Savelugu Nanton (SND) where IRS had been implemented from 2008 to 2014; Tolon Kumbungu (TKD) where IRS had been implemented between 2008 and 2012 and Tamale Metropolis (TML) with no history of IRS. Mosquitoes were morphologically identified to species level and into sibling species, using PCR. Samples of Anopheles gambiae sensu lato (s.l.) were examined for parity and infectivity. EIR was calculated from biting and infectivity rates of malaria vectors. Parity rates of An. gambiae s.l. decreased significantly (p < 0.0001) in SND from 44.8% in 2011 to 28.1% by 2014, and in TKD from 53.3% in 2011 to 46.6% in 2012 (p = 0.001). However 2 years after IRS was discontinued in TKD, the proportion of parous An. gambiae s.l. increased significantly to 68.5% in 2014 (p < 0.0001). Parity rates in the unsprayed district remained high throughout the study period, ranging between 68.6% in 2011 and 72.3% in 2014. The sum of monthly EIRs post-IRS season (July-December) in SND ranged between 2.1 and 6.3 infective bites/person/season (ib/p/s) during the 3 years that the district was sprayed with alphacypermethrin. EIR in SND was reduced to undetectable levels when the insecticide was switched to pirimiphos methyl CS in 2013 and 2014. Two years after IRS was withdrawn from TKD the sum of monthly EIRs (July-December) increased by about fourfold from 41.8 ib/p/s in 2012 to 154.4 ib/p/s in 2014. The EIR in the control area, TML, ranged between 35 ib/p/s in 2009 to 104.71 ib/p/s by 2014. This study demonstrates that IRS application did have a

  15. Indoor Residual Spraying Delivery Models to Prevent Malaria: Comparison of Community- and District-Based Approaches in Ethiopia

    PubMed Central

    Johns, Benjamin; Yihdego, Yemane Yeebiyo; Kolyada, Lena; Dengela, Dereje; Chibsa, Sheleme; Dissanayake, Gunawardena; George, Kristen; Taffese, Hiwot Solomon; Lucas, Bradford

    2016-01-01

    ABSTRACT Background: Indoor residual spraying (IRS) for malaria prevention has traditionally been implemented in Ethiopia by the district health office with technical and operational inputs from regional, zonal, and central health offices. The United States President's Malaria Initiative (PMI) in collaboration with the Government of Ethiopia tested the effectiveness and efficiency of integrating IRS into the government-funded community-based rural health services program. Methods: Between 2012 and 2014, PMI conducted a mixed-methods study in 11 districts of Oromia region to compare district-based IRS (DB IRS) and community-based IRS (CB IRS) models. In the DB IRS model, each district included 2 centrally located operational sites where spray teams camped during the IRS campaign and from which they traveled to the villages to conduct spraying. In the CB IRS model, spray team members were hired from the communities in which they operated, thus eliminating the need for transport and camping facilities. The study team evaluated spray coverage, the quality of spraying, compliance with environmental and safety standards, and cost and performance efficiency. Results: The average number of eligible structures found and sprayed in the CB IRS districts increased by 19.6% and 20.3%, respectively, between 2012 (before CB IRS) and 2013 (during CB IRS). Between 2013 and 2014, the numbers increased by about 14%. In contrast, in the DB IRS districts the number of eligible structures found increased by only 8.1% between 2012 and 2013 and by 0.4% between 2013 and 2014. The quality of CB IRS operations was good and comparable to that in the DB IRS model, according to wall bioassay tests. Some compliance issues in the first year of CB IRS implementation were corrected in the second year, bringing compliance up to the level of the DB IRS model. The CB IRS model had, on average, higher amortized costs per district than the DB IRS model but lower unit costs per structure sprayed and per

  16. Indoor Air Quality Guidelines for Pennsylvania Schools.

    ERIC Educational Resources Information Center

    Zimmerman, Robert S., Jr.

    This report provides information and practical guidance on how to prevent indoor air quality (IAQ) problems in schools, and it describes how to implement a practical plan of action using a minimal amount of resources. It includes general guidelines to prevent or help resolve IAQ problems, guidelines on specific indoor contaminants, recommendations…

  17. Healthy Indoor Environment Protocols for Home Energy Upgrades

    EPA Pesticide Factsheets

    This page contains the EPA-developed Healthy Indoor Environment Protocols for Home Energy Upgrades, a PDF guide that provides a set of best practices for improving indoor air quality in conjunction with energy upgrade work in homes.

  18. Combining indoor residual spraying and insecticide-treated nets for malaria control in Africa: a review of possible outcomes and an outline of suggestions for the future

    PubMed Central

    2011-01-01

    Insecticide-treated nets (ITNs) and indoor residual spraying (IRS) are currently the preferred methods of malaria vector control. In many cases, these methods are used together in the same households, especially to suppress transmission in holoendemic and hyperendemic scenarios. Though widespread, there has been limited evidence suggesting that such co-application confers greater protective benefits than either ITNs or IRS when used alone. Since both methods are insecticide-based and intradomicilliary, this article hypothesises that outcomes of their combination would depend on effects of the candidate active ingredients on mosquitoes that enter or those that attempt to enter houses. It is suggested here that enhanced household level protection can be achieved if the ITNs and IRS have divergent yet complementary properties, e.g. highly deterrent IRS compounds coupled with highly toxic ITNs. To ensure that the problem of insecticide resistance is avoided, the ITNs and IRS products should preferably be of different insecticide classes, e.g. pyrethroid-based nets combined with organophosphate or carbamate based IRS. The overall community benefits would however depend also on other factors such as proportion of people covered by the interventions and the behaviour of vector species. This article concludes by emphasizing the need for basic and operational research, including mathematical modelling to evaluate IRS/ITN combinations in comparison to IRS alone or ITNs alone. PMID:21798053

  19. Tanning and teens: Is indoor exposure the tip of the iceberg?

    PubMed Central

    Hay, Jennifer L.; Riley, Kristen E.; Geller, Alan C.

    2017-01-01

    Due to recent state regulations and the reduced availability of free-standing tanning salons, indoor tanning prevalence is beginning to decline. This may lead to unintended consequences – increases in outdoor intentional tanning. We advance a series of research directions to track and intervene to address all forms of intentional tanning. First, we advocate for enforcement of indoor tanning regulation and encourage collection of data on tanning salon compliance and alternative indoor tanning strategies. Second, we suggest questions about outdoor and indoor tanning should be included in national surveys. Third, we need to understand the potentially complex patterns of indoor and outdoor tanning that may exist among those who tan. Fourth, research examining changing motivations for intentional tanning is needed. Finally, indoor tanning intervention studies should include outdoor tanning as an outcome to examine the effect of interventions on these related risk behaviors. These advances will ensure the development of novel interventions to address intentional tanning through multiple routes, and to avoid any unintended negative consequence of indoor tanning regulation. The promising downward direction of indoor tanning use in the United States should now lead the public health field to sharpen its focus on outdoor tanning. PMID:28765337

  20. 76 FR 46677 - Indoor Tanning Services; Cosmetic Services Excise Taxes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-03

    ... 1545-BJ40 Indoor Tanning Services; Cosmetic Services Excise Taxes AGENCY: Internal Revenue Service (IRS... of public hearing on proposed rulemaking providing guidance on the indoor tanning services excise tax... indoor tanning services. DATES: The public hearing is being held on Tuesday, October 11, 2011, at 10 a.m...

  1. Experimental methods of indoor millimeter-wave radiometric imaging for personnel concealed contraband detection

    NASA Astrophysics Data System (ADS)

    Hu, Taiyang; Xiao, Zelong; Li, Hao; Lv, Rongchuan; Lu, Xuan

    2014-11-01

    The increasingly emerging terrorism attacks and violence crimes around the world have posed severe threats to public security, so carrying out relevant research on advanced experimental methods of personnel concealed contraband detection is crucial and meaningful. All of the advantages of imaging covertly, avoidance of interference with other systems, intrinsic property of being safe to persons under screening , and the superior ability of imaging through natural or manmade obscurants, have significantly combined to enable millimeter-wave (MMW) radiometric imaging to offer great potential in personnel concealed contraband detection. Based upon the current research status of MMW radiometric imaging and urgent demands of personnel security screening, this paper mainly focuses on the experimental methods of indoor MMW radiometric imaging. The reverse radiation noise resulting from super-heterodyne receivers seriously affects the image experiments carried out at short range, so both the generation mechanism and reducing methods of this noise are investigated. Then, the benefit of sky illumination no longer exists for the indoor radiometric imaging, and this leads to the decrease in radiometric temperature contrast between target and background. In order to enhance the radiometric temperature contrast for improving indoor imaging performance, the noise illumination technique is adopted in the indoor imaging scenario. In addition, the speed and accuracy of concealed contraband detection from acquired MMW radiometric images are usually restricted to the deficiencies in traditional artificial interpretation by security inspectors, thus an automatic recognition and location algorithm by integrating improved Fuzzy C-means clustering with moment invariants is put forward. A series of original results are also presented to demonstrate the significance and validity of these methods.

  2. "My children and I will no longer suffer from malaria": a qualitative study of the acceptance and rejection of indoor residual spraying to prevent malaria in Tanzania.

    PubMed

    Kaufman, Michelle R; Rweyemamu, Datius; Koenker, Hannah; Macha, Jacob

    2012-07-02

    The objective of this study was to identify attitudes and misconceptions related to acceptance or refusal of indoor residual spraying (IRS) in Tanzania for both the general population and among certain groups (e.g., farmers, fishermen, community leaders, and women). This study was a series of qualitative, semi-structured, in-depth interviews and focus group discussions conducted from October 2010 to March 2011 on Mainland Tanzania and Zanzibar. Three groups of participants were targeted: acceptors of IRS (those who have already had their homes sprayed), refusers (those whose communities have been sprayed, but refused to have their individual home sprayed), and those whose houses were about to be sprayed as part of IRS scale-up. Interviews were also conducted with farmers, fishermen, women, community leaders and members of non-government organizations responsible for community mobilization around IRS. Results showed refusers are a very small percentage of the population. They tend to be more knowledgeable people such as teachers, drivers, extension workers, and other civil servants who do not simply follow the orders of the local government or the sprayers, but are skeptical about the process until they see true results. Refusal took three forms: 1) refusing partially until thorough explanation is provided; 2) accepting spray to be done in a few rooms only; and 3) refusing outright. In most of the refusal interviews, refusers justified why their houses were not sprayed, often without admitting that they had refused. Reasons for refusal included initial ignorance about the reasons for IRS, uncertainty about its effectiveness, increased prevalence of other insects, potential physical side effects, odour, rumours about the chemical affecting fertility, embarrassment about moving poor quality possessions out of the house, and belief that the spray was politically motivated. To increase IRS acceptance, participants recommended more emphasis on providing thorough public

  3. Indoor Temperatures in Low Cost Housing in Johannesburg, South Africa.

    PubMed

    Naicker, Nisha; Teare, June; Balakrishna, Yusentha; Wright, Caradee Yael; Mathee, Angela

    2017-11-18

    Ambient and indoor temperature affects thermal comfort and human health. In a changing climate with a predicted change in temperature extremes, understanding indoor temperatures, both hot and cold, of different housing types is important. This study aimed to assess the hourly, daily and monthly variation in indoor temperatures in different housing types, namely formal houses, informal houses, flats, government-built low-cost houses and old, apartheid era low-cost housing, in five impoverished urban communities in Johannesburg, South Africa. During the cross-sectional survey of the Health, Environment and Development study data loggers were installed in 100 homes (20 per suburb) from February to May 2014. Indoor temperature and relative humidity were recorded on an hourly basis. Ambient outdoor temperatures were obtained from the nearest weather station. Indoor and outdoor temperature and relative humidity levels were compared; and an inter-comparison between the different housing types were also made. Apparent temperature was calculated to assess indoor thermal comfort. Data from 59 retrieved loggers showed a significant difference in monthly mean indoor temperature between the five different housing types ( p < 0.0001). Low cost government-built houses and informal settlement houses had the greatest variation in temperature and experienced temperatures between 4 and 5 °C warmer than outdoor temperatures. Housing types occupied by poor communities experienced indoor temperature fluctuations often greater than that observed for ambient temperatures. Families living in government-built low-cost and informally-constructed homes are the most at risk for indoor temperature extremes. These types of housing should be prioritised for interventions aimed at assisting families to cope with extreme temperatures, gaining optimal thermal comfort and preventing temperature-related health effects.

  4. Measuring nonsolar tanning behavior: indoor and sunless tanning.

    PubMed

    Lazovich, Deann; Stryker, Jo Ellen; Mayer, Joni A; Hillhouse, Joel; Dennis, Leslie K; Pichon, Latrice; Pagoto, Sherry; Heckman, Carolyn; Olson, Ardis; Cokkinides, Vilma; Thompson, Kevin

    2008-02-01

    To develop items to measure indoor tanning and sunless tanning that can be used to monitor trends in population surveys or to assess changes in behavior in intervention studies. A group of experts on indoor tanning convened in December 2005, as part of a national workshop to review the state of the evidence, define measurement issues, and develop items for ever tanned indoors, lifetime frequency, and past-year frequency for both indoor tanning and sunless tanning. Each item was subsequently assessed via in-person interviews for clarity, specificity, recall, and appropriateness of wording. Universities in Tennessee and Virginia, a medical center in Massachusetts, and a high school in New Hampshire. The study population comprised 24 adults and 7 adolescents. Participants understood indoor tanning to represent tanning from beds, booths, and lamps that emit artificial UV radiation, rather than sunless tanning, even though both can be obtained from a booth. Two items were required to distinguish manually applied from booth-applied sunless tanning products. Frequency of use was easier for participants to recall in the past year than for a lifetime. While indoor tanning items may be recommended with confidence for clarity, sunless tanning items require additional testing. Memory aids may be necessary to facilitate recall of lifetime use of nonsolar tanning. In addition, studies that assess reliability and validity of these measures are needed. Since study participants were primarily young and female, testing in other populations should also be considered.

  5. Reducing Health Risks from Indoor Exposures in Rapidly Developing Urban China

    PubMed Central

    Zhang, Yinping; Mo, Jinhan

    2013-01-01

    Background: Over the past two decades there has been a large migration of China’s population from rural to urban regions. At the same time, residences in cities have changed in character from single-story or low-rise buildings to high-rise structures constructed and furnished with many synthetic materials. As a consequence, indoor exposures (to pollutants with outdoor and indoor sources) have changed significantly. Objectives: We briefly discuss the inferred impact that urbanization and modernization have had on indoor exposures and public health in China. We argue that growing adverse health costs associated with these changes are not inevitable, and we present steps that could be taken to reduce indoor exposures to harmful pollutants. Discussion: As documented by China’s Ministry of Health, there have been significant increases in morbidity and mortality among urban residents over the past 20 years. Evidence suggests that the population’s exposure to air pollutants has contributed to increases in lung cancer, cardiovascular disease, pulmonary disease, and birth defects. Whether a pollutant has an outdoor or an indoor source, most exposure to the pollutant occurs indoors. Going forward, indoor exposures can be reduced by limiting the ingress of outdoor pollutants (while providing adequate ventilation with clean air), minimizing indoor sources of pollutants, updating government policies related to indoor pollution, and addressing indoor air quality during a building’s initial design. Conclusions: Taking the suggested steps could lead to significant reductions in morbidity and mortality, greatly reducing the societal costs associated with pollutant derived ill health. PMID:23665813

  6. Source Apportionment and Influencing Factor Analysis of Residential Indoor PM2.5 in Beijing

    PubMed Central

    Yang, Yibing; Liu, Liu; Xu, Chunyu; Li, Na; Liu, Zhe; Wang, Qin; Xu, Dongqun

    2018-01-01

    In order to identify the sources of indoor PM2.5 and to check which factors influence the concentration of indoor PM2.5 and chemical elements, indoor concentrations of PM2.5 and its related elements in residential houses in Beijing were explored. Indoor and outdoor PM2.5 samples that were monitored continuously for one week were collected. Indoor and outdoor concentrations of PM2.5 and 15 elements (Al, As, Ca, Cd, Cu, Fe, K, Mg, Mn, Na, Pb, Se, Tl, V, Zn) were calculated and compared. The median indoor concentration of PM2.5 was 57.64 μg/m3. For elements in indoor PM2.5, Cd and As may be sensitive to indoor smoking, Zn, Ca and Al may be related to indoor sources other than smoking, Pb, V and Se may mainly come from outdoor. Five factors were extracted for indoor PM2.5 by factor analysis, explained 76.8% of total variance, outdoor sources contributed more than indoor sources. Multiple linear regression analysis for indoor PM2.5, Cd and Pb was performed. Indoor PM2.5 was influenced by factors including outdoor PM2.5, smoking during sampling, outdoor temperature and time of air conditioner use. Indoor Cd was affected by factors including smoking during sampling, outdoor Cd and building age. Indoor Pb concentration was associated with factors including outdoor Pb and time of window open per day, building age and RH. In conclusion, indoor PM2.5 mainly comes from outdoor sources, and the contributions of indoor sources also cannot be ignored. Factors associated indoor and outdoor air exchange can influence the concentrations of indoor PM2.5 and its constituents. PMID:29621164

  7. Source Apportionment and Influencing Factor Analysis of Residential Indoor PM2.5 in Beijing.

    PubMed

    Yang, Yibing; Liu, Liu; Xu, Chunyu; Li, Na; Liu, Zhe; Wang, Qin; Xu, Dongqun

    2018-04-05

    In order to identify the sources of indoor PM 2.5 and to check which factors influence the concentration of indoor PM 2.5 and chemical elements, indoor concentrations of PM 2.5 and its related elements in residential houses in Beijing were explored. Indoor and outdoor PM 2.5 samples that were monitored continuously for one week were collected. Indoor and outdoor concentrations of PM 2.5 and 15 elements (Al, As, Ca, Cd, Cu, Fe, K, Mg, Mn, Na, Pb, Se, Tl, V, Zn) were calculated and compared. The median indoor concentration of PM 2.5 was 57.64 μg/m³. For elements in indoor PM 2.5 , Cd and As may be sensitive to indoor smoking, Zn, Ca and Al may be related to indoor sources other than smoking, Pb, V and Se may mainly come from outdoor. Five factors were extracted for indoor PM 2.5 by factor analysis, explained 76.8% of total variance, outdoor sources contributed more than indoor sources. Multiple linear regression analysis for indoor PM 2.5 , Cd and Pb was performed. Indoor PM 2.5 was influenced by factors including outdoor PM 2.5 , smoking during sampling, outdoor temperature and time of air conditioner use. Indoor Cd was affected by factors including smoking during sampling, outdoor Cd and building age. Indoor Pb concentration was associated with factors including outdoor Pb and time of window open per day, building age and RH. In conclusion, indoor PM 2.5 mainly comes from outdoor sources, and the contributions of indoor sources also cannot be ignored. Factors associated indoor and outdoor air exchange can influence the concentrations of indoor PM 2.5 and its constituents.

  8. Environment and development of respiratory allergy. II. Indoors.

    PubMed

    D'Amato, G; Liccardi, G; D'Amato, M

    1994-12-01

    Even if it is difficult to obtain correct epidemiological evidence, there is a body of evidence which suggests that the frequency of allergic respiratory diseases is increasing. The majority of atopic patients, in particular in childhood and adolescence, develop immunoglobulin E (IgE) antibodies with clinical symptoms to aeroallergens, such as those derived from house dust mites, pollens and pets. Since, in the economically-developed countries individuals spend most of their time indoors (home, school and workplace), indoor pollutants (tobacco smoke etc.) and allergens (house dust mite, cats, etc.) are the most important source of exposure. Indoor allergens are associated with a wide variety of particles in a broad size range, only some of which are microscopically identifiable, culturable, or detectable with existing immunoassay. Evaluation of indoor allergens requires both air and source sampling, and several different analytical techniques. It is likely that the increased prevalence of allergy and asthma may be caused in the indoor environment by the synergistic action of air pollution (in particular derived from tobacco smoking) with allergic sensitization. Passive smoking in infancy has also been involved in the airways allergic sensitization to common aeroallergens.

  9. Health effects from indoor air pollution: case studies.

    PubMed

    White, L E; Clarkson, J R; Chang, S N

    1987-01-01

    In recent years there has been a growing awareness of the health effects associated with the presence of contaminants in indoor air. Numerous agents can accumulate in public buildings, homes and automobiles as a result of ongoing activities that normally occur in these closed spaces. Ventilation is a major factor in the control of indoor air pollutants since proper movement of air can prevent or minimize the build up of compounds in buildings. The recent emphasis on energy conservation has lead to measures which economize on energy for heating and air conditioning, but which also trap pollutants within a building. Three cases of indoor air pollution were investigated. A typical investigation of indoor air pollutant problems includes the following: interviews with building occupants; history of the building with regard to maintenance, pesticide treatment, etc.; a survey of the building and ventilation; and when warranted, sampling and analysis of air. Each case presented is unique in that atypical situations caused agents to accumulate in a building or section of a building. The indoor air problems in these cases were solved by identifying and removing the source of the offending agent and/or improving the ventilation in the building.

  10. Indoor Air Pollution in Non Ac Passenger Bus

    NASA Astrophysics Data System (ADS)

    El Husna, Iksiroh; Unzilatirrizqi, Rizal D. Yan El; Karyanto, Yudi; Sunoko, Henna R.

    2018-02-01

    Passenger buses have been one of favorite means of transportation in Indonesia due to its affordability and flexibility. Intensity of human activities during the trip in the buses have a potential of causing indoor air pollution (polusi udara dalam ruang; PUDR). The indoor air pollution has an impact of 1000-time bigger than outdoor air pollution (polusi udara luar ruang; PULR) on lung. This study aimed to find out indoor air pollution rate of non air conditioned buses using an approach to biological agent pollutant source. The study applied an analysis restricted to microorganisms persistence as one of the sources of the indoor air pollution. The media were placed in different parts of the non AC buses. This study revealed that fungs were found in the non AC buses. They became contaminants and developed pathogenic bacteria that caused air pollution.

  11. Indoor pollution and its impact on respiratory health.

    PubMed

    Bardana, E J

    2001-12-01

    This overview discusses the respiratory complications of indoor air pollution, emphasizing the most common pollutants that individuals are likely to encounter outside the workplace. Data were obtained from a review of the recent literature. The expert opinion of the author was used to select and synthesize relevant data on this multifaceted subject. There have been a number of studies documenting an association between exposure to indoor allergens and development of both sensitization and asthma in children. In addition to classic allergens, chemical indoor air pollution may also exert an adverse effect on both the upper and lower respiratory tract by a variety of nonimmunologic, irritative mechanisms. Our understanding of the adverse effects of indoor air pollution on health and comfort has broadened in recent years. It has supplied a credible framework for developing and implementing a variety of control strategies.

  12. Distribution of indoor radon concentrations in Pennsylvania, 1990-2007

    USGS Publications Warehouse

    Gross, Eliza L.

    2013-01-01

    Median indoor radon concentrations aggregated according to geologic units and hydrogeologic settings are useful for drawing general conclusions about the occurrence of indoor radon in specific geologic units and hydrogeologic settings, but the associated data and maps have limitations. The aggregated indoor radon data have testing and spatial accuracy limitations due to lack of available information regarding testing conditions and the imprecision of geocoded test locations. In addition, the associated data describing geologic units and hydrogeologic settings have spatial and interpretation accuracy limitations, which are a result of using statewide data to define conditions at test locations and geologic data that represent a broad interpretation of geologic units across the State. As a result, indoor air radon concentration distributions are not proposed for use in predicting individual concentrations at specific sites nor for use as a decision-making tool for property owners to decide whether to test for indoor radon concentrations at specific property locations.

  13. Indoor Environmental Control Practices and Asthma Management.

    PubMed

    Matsui, Elizabeth C; Abramson, Stuart L; Sandel, Megan T

    2016-11-01

    Indoor environmental exposures, particularly allergens and pollutants, are major contributors to asthma morbidity in children; environmental control practices aimed at reducing these exposures are an integral component of asthma management. Some individually tailored environmental control practices that have been shown to reduce asthma symptoms and exacerbations are similar in efficacy and cost to controller medications. As a part of developing tailored strategies regarding environmental control measures, an environmental history can be obtained to evaluate the key indoor environmental exposures that are known to trigger asthma symptoms and exacerbations, including both indoor pollutants and allergens. An environmental history includes questions regarding the presence of pets or pests or evidence of pests in the home, as well as knowledge regarding whether the climatic characteristics in the community favor dust mites. In addition, the history focuses on sources of indoor air pollution, including the presence of smokers who live in the home or care for children and the use of gas stoves and appliances in the home. Serum allergen-specific immunoglobulin E antibody tests can be performed or the patient can be referred for allergy skin testing to identify indoor allergens that are most likely to be clinically relevant. Environmental control strategies are tailored to each potentially relevant indoor exposure and are based on knowledge of the sources and underlying characteristics of the exposure. Strategies include source removal, source control, and mitigation strategies, such as high-efficiency particulate air purifiers and allergen-proof mattress and pillow encasements, as well as education, which can be delivered by primary care pediatricians, allergists, pediatric pulmonologists, other health care workers, or community health workers trained in asthma environmental control and asthma education. Copyright © 2016 by the American Academy of Pediatrics.

  14. Preventing skin cancer through reduction of indoor tanning: current evidence.

    PubMed

    Watson, Meg; Holman, Dawn M; Fox, Kathleen A; Guy, Gery P; Seidenberg, Andrew B; Sampson, Blake P; Sinclair, Craig; Lazovich, DeAnn

    2013-06-01

    Exposure to ultraviolet radiation from indoor tanning devices (tanning beds, booths, and sun lamps) or from the sun contributes to the risk of skin cancer, including melanoma, which is the type of skin cancer responsible for most deaths. Indoor tanning is common among certain groups, especially among older adolescents and young adults, adolescent girls and young women, and non-Hispanic whites. Increased understanding of the health risks associated with indoor tanning has led to many efforts to reduce use. Most environmental and systems efforts in the U.S. (e.g., age limits or requiring parental consent/accompaniment) have occurred at the state level. At the national level, the U.S. Food and Drug Administration and the Federal Trade Commission regulate indoor tanning devices and advertising, respectively. The current paper provides a brief review of (1) the evidence on indoor tanning as a risk factor for skin cancer; (2) factors that may influence use of indoor tanning devices at the population level; and (3) various environmental and systems options available for consideration when developing strategies to reduce indoor tanning. This information provides the context and background for the companion paper in this issue of the American Journal of Preventive Medicine, which summarizes highlights from an informal expert meeting convened by the CDC in August 2012 to identify opportunities to prevent skin cancer by reducing use of indoor tanning devices. Published by Elsevier Inc.

  15. Indoor Air Quality: A Guide for Educators.

    ERIC Educational Resources Information Center

    California State Dept. of Education, Sacramento.

    Indoor air quality is a major concern for educators involved in the development of new school facilities, or the remodeling and maintenance of existing ones. This guide addresses the issue of air quality, the health concerns involved, and procedures for minimizing the impact of pollutants in the school environment. It defines common indoor air…

  16. Curbing indoor mold growth with mold inhibitors

    Treesearch

    Carol A. Clausen; Vina W. Yang

    2004-01-01

    Environmentally acceptable mold inhibitors are needed to curb the growth of mold fungi in woodframe housing when moisture management measures fail. Excess indoor moisture can lead to rapid mold establishment which, in turn, can have deleterious affects on indoor air quality. Compounds with known mold inhibitory properties and low mammalian toxicity, such as food...

  17. Canoe: An Autonomous Infrastructure-Free Indoor Navigation System.

    PubMed

    Dong, Kai; Wu, Wenjia; Ye, Haibo; Yang, Ming; Ling, Zhen; Yu, Wei

    2017-04-30

    The development of the Internet of Things (IoT) has accelerated research in indoor navigation systems, a majority of which rely on adequate wireless signals and sources. Nonetheless, deploying such a system requires periodic site-survey, which is time consuming and labor intensive. To address this issue, in this paper we present Canoe , an indoor navigation system that considers shopping mall scenarios. In our system, we do not assume any prior knowledge, such as floor-plan or the shop locations, access point placement or power settings, historical RSS measurements or fingerprints, etc. Instead, Canoe requires only that the shop owners collect and publish RSS values at the entrances of their shops and can direct a consumer to any of these shops by comparing the observed RSS values. The locations of the consumers and the shops are estimated using maximum likelihood estimation. In doing this, the direction of the target shop relative to the current orientation of the consumer can be precisely computed, such that the direction that a consumer should move can be determined. We have conducted extensive simulations using a real-world dataset. Our experiments in a real shopping mall demonstrate that if 50% of the shops publish their RSS values, Canoe can precisely navigate a consumer within 30 s, with an error rate below 9%.

  18. Canoe: An Autonomous Infrastructure-Free Indoor Navigation System

    PubMed Central

    Dong, Kai; Wu, Wenjia; Ye, Haibo; Yang, Ming; Ling, Zhen; Yu, Wei

    2017-01-01

    The development of the Internet of Things (IoT) has accelerated research in indoor navigation systems, a majority of which rely on adequate wireless signals and sources. Nonetheless, deploying such a system requires periodic site-survey, which is time consuming and labor intensive. To address this issue, in this paper we present Canoe, an indoor navigation system that considers shopping mall scenarios. In our system, we do not assume any prior knowledge, such as floor-plan or the shop locations, access point placement or power settings, historical RSS measurements or fingerprints, etc. Instead, Canoe requires only that the shop owners collect and publish RSS values at the entrances of their shops and can direct a consumer to any of these shops by comparing the observed RSS values. The locations of the consumers and the shops are estimated using maximum likelihood estimation. In doing this, the direction of the target shop relative to the current orientation of the consumer can be precisely computed, such that the direction that a consumer should move can be determined. We have conducted extensive simulations using a real-world dataset. Our experiments in a real shopping mall demonstrate that if 50% of the shops publish their RSS values, Canoe can precisely navigate a consumer within 30 s, with an error rate below 9%. PMID:28468291

  19. Exposure to Indoor Tanning Without Burning and Melanoma Risk by Sunburn History

    PubMed Central

    Vogel, Rachel Isaksson; Ahmed, Rehana L.; Nelson, Heather H.; Berwick, Marianne; Weinstock, Martin A.

    2014-01-01

    Indoor tanning is carcinogenic to humans. Individuals report that they tan indoors before planning to be in the sun to prevent sunburns, but whether skin cancer is subsequently reduced is unknown. Using a population-based case–control study, we calculated the association between melanoma and indoor tanning after excluding exposed participants reporting indoor tanning–related burns, stratified by their number of lifetime sunburns (0, 1–2, 3–5, >5). Confounding was addressed using propensity score analysis methods. All statistical tests were two-sided. We observed increased risk of melanoma across all sunburn categories for participants who had tanned indoors without burning compared with those who never tanned indoors, including those who reported zero lifetime sunburns (odds ratio = 3.87; 95% confidence interval = 1.68 to 8.91; P = .002). These data provide evidence that indoor tanning is a risk factor for melanoma even among persons who reported never experiencing burns from indoor tanning or outdoor sun exposure. PMID:25031276

  20. Exposure to Indoor Tanning Without Burning and Melanoma Risk by Sunburn History

    PubMed Central

    Vogel, Rachel Isaksson; Ahmed, Rehana L.; Nelson, Heather H.; Berwick, Marianne; Weinstock, Martin A.

    2014-01-01

    Indoor tanning is carcinogenic to humans. Individuals report that they tan indoors before planning to be in the sun to prevent sunburns, but whether skin cancer is subsequently reduced is unknown. Using a population-based case–control study, we calculated the association between melanoma and indoor tanning after excluding exposed participants reporting indoor tanning–related burns, stratified by their number of lifetime sunburns (0, 1–2, 3–5, >5). Confounding was addressed using propensity score analysis methods. All statistical tests were two-sided. We observed increased risk of melanoma across all sunburn categories for participants who had tanned indoors without burning compared with those who never tanned indoors, including those who reported zero lifetime sunburns (odds ratio = 3.87; 95% confidence interval = 1.68 to 8.91; P = .002). These data provide evidence that indoor tanning is a risk factor for melanoma even among persons who reported never experiencing burns from indoor tanning or outdoor sun exposure. PMID:24872541

  1. Human physiological responses to wooden indoor environment.

    PubMed

    Zhang, Xi; Lian, Zhiwei; Wu, Yong

    2017-05-15

    Previous studies are mainly focused on non-wooden environments, whereas few are concerned with wooden ones. How wooden indoor environments impact the physiology of the occupants is still unclear. The purpose of this study was to explore the distinct physiological responses to wooden and non-wooden indoor environments, assessed by physiological parameters tests including blood pressure, electrocardiogram measurements, electro-dermal activity, oxyhemoglobin saturation, skin temperature, and near distance vision. Twenty healthy adults participated in this experiment, and their physiological responses were evaluated in a 90minute investigation. The results illustrated that; less tension and fatigue were generated in the wooden rooms than in the non-wooden rooms when the participants did their work. In addition, the study also found that the wooden environments benefit the autonomic nervous system, respiratory system, and visual system. Moreover, wooden rooms play a valuable role in physiological regulation and ease function especially after a consecutive period of work. These results provide an experimental basis to support that wooden environment is beneficial to indoor occupants than the non-wooden indoor environment. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. EML indoor radon workshop, 1982

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    George, A.C.; Lowder, W.; Fisenne, I.

    1983-07-01

    A workshop on indoor radon, held at the Environmental Measurements Laboratory (EML) on November 30 and December 1, 1982, covered recent developments in radon daughter research and development. Thirty papers were presented dealing with standardization and quality assurance measurement methods, surveys, measurements strategy, physical mechanisms of radon and radon daughter transport and development of guidance standards for indoor exposures. The workshop concluded with a planning session that identified the following needs: (1) national and international intercomparisons of techniques for measuring radon and radon daughter concentrations, working level and radon exhalation flux density; (2) development and refinement of practical measurement techniquesmore » for thoron and its daughter products; (3) quantitative definition of the sources of indoor radon and the mechanisms of transport into structures; (4) better knowledge of the physical properties of radon daughters; (5) more complete and accurate data on the population exposure to radon, which can only be met by broadly based surveys; and (6) more international cooperation and information exchange among countries with major research programs.« less

  3. A proposed UAV for indoor patient care.

    PubMed

    Todd, Catherine; Watfa, Mohamed; El Mouden, Yassine; Sahir, Sana; Ali, Afrah; Niavarani, Ali; Lutfi, Aoun; Copiaco, Abigail; Agarwal, Vaibhavi; Afsari, Kiyan; Johnathon, Chris; Okafor, Onyeka; Ayad, Marina

    2015-09-10

    Indoor flight, obstacle avoidance and client-server communication of an Unmanned Aerial Vehicle (UAV) raises several unique research challenges. This paper examines current methods and associated technologies adapted within the literature toward autonomous UAV flight, for consideration in a proposed system for indoor healthcare administration with a quadcopter. We introduce Healthbuddy, a unique research initiative towards overcoming challenges associated with indoor navigation, collision detection and avoidance, stability, wireless drone-server communications and automated decision support for patient care in a GPS-denied environment. To address the identified research deficits, a drone-based solution is presented. The solution is preliminary as we develop and refine the suggested algorithms and hardware system to achieve the research objectives.

  4. Foliage Plants for Improving Indoor Air Quality

    NASA Technical Reports Server (NTRS)

    Wolverton, B. C.

    1988-01-01

    NASA's research with foliage houseplants during the past 10 years has produced a new concept in indoor air quality improvement. This new and exciting technology is quite simple. Both plant leaves and roots are utilized in removing trace levels of toxic vapors from inside tightly sealed buildings. Low levels of chemicals such as carbon monoxide and formaldehyde can be removed from indoor environments by plant leaves alone, while higher concentrations of numerous toxic chemicals can be removed by filtering indoor air through the plant roots surrounded by activated carbon. The activated carbon absorbs large quantities of the toxic chemicals and retains them until the plant roots and associated microorganisms degrade and assimilate these chemicals.

  5. Indoor Air Quality: Is Increased Ventilation the Answer?

    ERIC Educational Resources Information Center

    Hansen, Shirley

    1989-01-01

    Explains how indoor air quality is affected by pollutants in the air and also by temperature, humidity, and ventilation. Increased ventilation alone seldom solves the "sick building syndrome." Lists ways to improve indoor air quality and optimize energy efficiency. (MLF)

  6. Design and Development of a Nearable Wireless System to Control Indoor Air Quality and Indoor Lighting Quality.

    PubMed

    Salamone, Francesco; Belussi, Lorenzo; Danza, Ludovico; Galanos, Theodore; Ghellere, Matteo; Meroni, Italo

    2017-05-04

    The article describes the results of the project "open source smart lamp" aimed at designing and developing a smart object able to manage and control the indoor environmental quality (IEQ) of the built environment. A first version of this smart object, built following a do-it-yourself (DIY) approach using a microcontroller, an integrated temperature and relative humidity sensor, and techniques of additive manufacturing, allows the adjustment of the indoor thermal comfort quality (ICQ), by interacting directly with the air conditioner. As is well known, the IEQ is a holistic concept including indoor air quality (IAQ), indoor lighting quality (ILQ) and acoustic comfort, besides thermal comfort. The upgrade of the smart lamp bridges the gap of the first version of the device providing the possibility of interaction with the air exchange unit and lighting system in order to get an overview of the potential of a nearable device in the management of the IEQ. The upgraded version was tested in a real office equipped with mechanical ventilation and an air conditioning system. This office was occupied by four workers. The experiment is compared with a baseline scenario and the results show how the application of the nearable device effectively optimizes both IAQ and ILQ.

  7. Design and Development of a Nearable Wireless System to Control Indoor Air Quality and Indoor Lighting Quality

    PubMed Central

    Salamone, Francesco; Belussi, Lorenzo; Danza, Ludovico; Galanos, Theodore; Ghellere, Matteo; Meroni, Italo

    2017-01-01

    The article describes the results of the project “open source smart lamp” aimed at designing and developing a smart object able to manage and control the indoor environmental quality (IEQ) of the built environment. A first version of this smart object, built following a do-it-yourself (DIY) approach using a microcontroller, an integrated temperature and relative humidity sensor, and techniques of additive manufacturing, allows the adjustment of the indoor thermal comfort quality (ICQ), by interacting directly with the air conditioner. As is well known, the IEQ is a holistic concept including indoor air quality (IAQ), indoor lighting quality (ILQ) and acoustic comfort, besides thermal comfort. The upgrade of the smart lamp bridges the gap of the first version of the device providing the possibility of interaction with the air exchange unit and lighting system in order to get an overview of the potential of a nearable device in the management of the IEQ. The upgraded version was tested in a real office equipped with mechanical ventilation and an air conditioning system. This office was occupied by four workers. The experiment is compared with a baseline scenario and the results show how the application of the nearable device effectively optimizes both IAQ and ILQ. PMID:28471398

  8. ASSESSING ALLERGENICITY OF INDOOR AIR FUNGAL CONTAMINANTS

    EPA Science Inventory

    Assessing Allergenicity of Indoor Air Fungal Contaminants
    M D W Ward1, M E Viana2, N Haykal-Coates1, L B Copeland1, S H Gavett1, and MJ K Selgrade1. 1US EPA, ORD, NHEERL, RTP, NC, USA. 2NCSU, CVM, Raleigh, NC, USA.
    Rationale: The indoor environment has increased in impor...

  9. Parents' Guide to School Indoor Air Quality.

    ERIC Educational Resources Information Center

    Healthy Schools Network, Inc., Albany, NY.

    This parents' guide presents articles on school indoor air pollution, children's health and the symptoms of indoor air pollution, and how schools can improve their air quality. Also included are tips on what to do if the school ignores air quality problems, and some examples of what school districts should be doing to improve their air quality.…

  10. Loudness and annoyance response to simulated outdoor and indoor sonic booms

    NASA Technical Reports Server (NTRS)

    Leatherwood, Jack D.; Sullivan, Brenda M.

    1993-01-01

    The sonic boom simulator of the Langley Research Center was used to quantify subjective loudness and annoyance response to simulated indoor and outdoor sonic boom signatures. The indoor signatures were derived from the outdoor signatures by application of house filters that approximated the noise reduction characteristics of a residential structure. Two indoor listening situations were simulated: one with the windows open and the other with the windows closed. Results were used to assess loudness and annoyance as sonic boom criterion measures and to evaluate several metrics as estimators of loudness and annoyance. The findings indicated that loudness and annoyance were equivalent criterion measures for outdoor booms but not for indoor booms. Annoyance scores for indoor booms were significantly higher than indoor loudness scores. Thus, annoyance was recommended as the criterion measure of choice for general use in assessing sonic boom subjective effects. Perceived level was determined to be the best estimator of annoyance for both indoor and outdoor booms, and of loudness for outdoor booms. It was recommended as the metric of choice for predicting sonic boom subjective effects.

  11. THE ALLERGENIC POTENTIAL OF INDOOR AIR FUNGAL CONTAMINANTS

    EPA Science Inventory

    ABSTRACT

    The indoor environment has increased in importance to children's health with children now spending more than 90% of their time indoors. Molds are an important component of this environment and have been associated with exacerbation of asthma. Their contribution t...

  12. Study of indoor radon distribution using measurements and CFD modeling.

    PubMed

    Chauhan, Neetika; Chauhan, R P; Joshi, M; Agarwal, T K; Aggarwal, Praveen; Sahoo, B K

    2014-10-01

    Measurement and/or prediction of indoor radon ((222)Rn) concentration are important due to the impact of radon on indoor air quality and consequent inhalation hazard. In recent times, computational fluid dynamics (CFD) based modeling has become the cost effective replacement of experimental methods for the prediction and visualization of indoor pollutant distribution. The aim of this study is to implement CFD based modeling for studying indoor radon gas distribution. This study focuses on comparison of experimentally measured and CFD modeling predicted spatial distribution of radon concentration for a model test room. The key inputs for simulation viz. radon exhalation rate and ventilation rate were measured as a part of this study. Validation experiments were performed by measuring radon concentration at different locations of test room using active (continuous radon monitor) and passive (pin-hole dosimeters) techniques. Modeling predictions have been found to be reasonably matching with the measurement results. The validated model can be used to understand and study factors affecting indoor radon distribution for more realistic indoor environment. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Indoor Map Aided Wi-Fi Integrated Lbs on Smartphone Platforms

    NASA Astrophysics Data System (ADS)

    Yu, C.; El-Sheimy, N.

    2017-09-01

    In this research, an indoor map aided INS/Wi-Fi integrated location based services (LBS) applications is proposed and implemented on smartphone platforms. Indoor map information together with measurements from an inertial measurement unit (IMU) and Received Signal Strength Indicator (RSSI) value from Wi-Fi are collected to obtain an accurate, continuous, and low-cost position solution. The main challenge of this research is to make effective use of various measurements that complement each other without increasing the computational burden of the system. The integrated system in this paper includes three modules: INS, Wi-Fi (if signal available) and indoor maps. A cascade structure Particle/Kalman filter framework is applied to combine the different modules. Firstly, INS position and Wi-Fi fingerprint position integrated through Kalman filter for estimating positioning information. Then, indoor map information is applied to correct the error of INS/Wi-Fi estimated position through particle filter. Indoor tests show that the proposed method can effectively reduce the accumulation positioning errors of stand-alone INS systems, and provide stable, continuous and reliable indoor location service.

  14. wayGoo: a platform for geolocating and managing indoor and outdoor spaces

    NASA Astrophysics Data System (ADS)

    Thomopoulos, Stelios C. A.; Karafylli, Christina; Karafylli, Maria; Motos, Dionysis; Lampropoulos, Vassilis; Dimitros, Kostantinos; Margonis, Christos

    2016-05-01

    wayGoo2 is a platform for Geolocating and Managing indoor and outdoor spaces and content with multidimensional indoor and outdoor Navigation and Guidance. Its main components are a Geographic Information System, a back-end server, front-end applications and a web-based Content Management System (CMS). It constitutes a fully integrated 2D/3D space and content management system that creates a repository that consists of a database, content components and administrative data. wayGoo can connect to any third party database and event management data-source. The platform is secure as the data is only available through a Restful web service using https security protocol in conjunction with an API key used for authentication. To enhance users experience, wayGoo makes the content available by extracting components out of the repository and constructing targeted applications. The wayGoo platform supports geo-referencing of indoor and outdoor information and use of metadata. It also allows the use of existing information such as maps and databases. The platform enables planning through integration of content that is connected either spatially, temporally or contextually, and provides immediate access to all spatial data through interfaces and interactive 2D and 3D representations. wayGoo constitutes a mean to document and preserve assets through computerized techniques and provides a system that enhances the protection of your space, people and guests when combined with wayGoo notification and alert system. It constitutes a strong marketing tool providing staff and visitors with an immersive tool for navigation in indoor spaces and allowing users to organize their agenda and to discover events through wayGoo event scheduler and recommendation system. Furthermore, the wayGoo platform can be used in Security applications and event management, e.g. CBRNE incidents, man-made and natural disasters, etc., to document and geolocate information and sensor data (off line and real time

  15. UniDrug-target: a computational tool to identify unique drug targets in pathogenic bacteria.

    PubMed

    Chanumolu, Sree Krishna; Rout, Chittaranjan; Chauhan, Rajinder S

    2012-01-01

    Targeting conserved proteins of bacteria through antibacterial medications has resulted in both the development of resistant strains and changes to human health by destroying beneficial microbes which eventually become breeding grounds for the evolution of resistances. Despite the availability of more than 800 genomes sequences, 430 pathways, 4743 enzymes, 9257 metabolic reactions and protein (three-dimensional) 3D structures in bacteria, no pathogen-specific computational drug target identification tool has been developed. A web server, UniDrug-Target, which combines bacterial biological information and computational methods to stringently identify pathogen-specific proteins as drug targets, has been designed. Besides predicting pathogen-specific proteins essentiality, chokepoint property, etc., three new algorithms were developed and implemented by using protein sequences, domains, structures, and metabolic reactions for construction of partial metabolic networks (PMNs), determination of conservation in critical residues, and variation analysis of residues forming similar cavities in proteins sequences. First, PMNs are constructed to determine the extent of disturbances in metabolite production by targeting a protein as drug target. Conservation of pathogen-specific protein's critical residues involved in cavity formation and biological function determined at domain-level with low-matching sequences. Last, variation analysis of residues forming similar cavities in proteins sequences from pathogenic versus non-pathogenic bacteria and humans is performed. The server is capable of predicting drug targets for any sequenced pathogenic bacteria having fasta sequences and annotated information. The utility of UniDrug-Target server was demonstrated for Mycobacterium tuberculosis (H37Rv). The UniDrug-Target identified 265 mycobacteria pathogen-specific proteins, including 17 essential proteins which can be potential drug targets. UniDrug-Target is expected to accelerate

  16. Indoor unit for electric heat pump

    DOEpatents

    Draper, R.; Lackey, R.S.; Fagan, T.J. Jr.; Veyo, S.E.; Humphrey, J.R.

    1984-05-22

    An indoor unit for an electric heat pump is provided in modular form including a refrigeration module, an air mover module, and a resistance heat package module, the refrigeration module including all of the indoor refrigerant circuit components including the compressor in a space adjacent the heat exchanger, the modules being adapted to be connected to air flow communication in several different ways as shown to accommodate placement of the unit in various orientations. 9 figs.

  17. Indoor Tanning Among High School Students in the United States, 2009 and 2011

    PubMed Central

    Guy, Gery P.; Berkowitz, Zahava; Tai, Eric; Holman, Dawn M.; Jones, Sherry Everett; Richardson, Lisa C.

    2015-01-01

    IMPORTANCE Indoor tanning is associated with an increased risk of skin cancer, including melanoma, and is particularly dangerous for younger and more frequent indoor tanners. OBJECTIVE To examine the prevalence of indoor tanning and frequent indoor tanning (≥10 times during the 12 months before each survey) and their association with health-related behaviors. DESIGN, SETTING, AND PARTICIPANTS A cross-sectional study examined data from the 2009 and 2011 national Youth Risk Behavior Surveys, which used nationally representative samples of US high school students representing approximately 15.5 million students each survey year. The study included 25 861 students who answered the indoor tanning question. MAIN OUTCOMES AND MEASURES The prevalence of indoor tanning and frequent indoor tanning were examined as well as their association with demographic characteristics and health-related behaviors using multivariable logistic regression modeling. RESULTS The prevalence of indoor tanning was greater among female, older, and non-Hispanic white students. Indoor tanning was highest among female students aged 18 years or older, with 31.5% engaging in indoor tanning in 2011, and among non-Hispanic white female students, with 29.3% engaging in indoor tanning in 2011. Among female students, the adjusted prevalence of indoor tanning decreased from 26.4% in 2009 to 20.7% in 2011. Among female and male students, indoor tanning was associated with other risk-taking behaviors, such as binge drinking (P < .001 and P = .006, respectively), unhealthy weight control practices (P < .001, for both), and having sexual intercourse (P < .001, for both). Additionally, indoor tanning among female students was associated with using illegal drugs (P < .001) and having sexual intercourse with 4 or more persons (P = .03); use among male students was associated with taking steroids without a physician’s prescription (P < .001), smoking cigarettes daily (P = .03), and attempting suicide (P = .006

  18. Changes in indoor pollutants since the 1950s

    NASA Astrophysics Data System (ADS)

    Weschler, Charles J.

    Over the past half-century there have been major changes in building materials and consumer products used indoors. Composite-wood, synthetic carpets, polymeric flooring, foam cushioning, plastic items and scented cleaning agents have become ubiquitous. The same is true for mechanical and electrical appliances such as washer/dryers, TVs and computers. These materials and products emit an array of chemicals including solvents, unreacted monomers, and additives. The consequent changes in emission profiles for indoor pollutants have been accompanied by modifications in building operations. Residences and non-residences are less ventilated than they were decades ago. Air-conditioned buildings are more numerous, especially in certain parts of the world. Most of these recirculate a high fraction of their air. The personal habits of building occupants, including the fraction who smoke indoors, have also changed. Taken together, these changes have altered the kind and concentrations of chemicals that occupants are exposed to in their homes, workplaces and schools. Since the 1950s, levels of certain indoor pollutants (e.g., formaldehyde, aromatic and chlorinated solvents, chlorinated pesticides, PCBs) have increased and then decreased. Levels of other indoor pollutants have increased and remain high (e.g., phthalate esters, brominated flame-retardants, nonionic surfactants and their degradation products). Many of the chemicals presently found in indoor environments, as well as in the blood and urine of occupants, were not present 50 years ago. Given the public's exposure to such species, there would be exceptional value in monitoring networks that provided cross-sectional and longitudinal information regarding pollutants found in representative buildings.

  19. DETERMINATION OF PARTICLE DEPOSITION RATES FOR COOKING AND OTHER INDOOR SOURCE

    EPA Science Inventory

    Residential indoor particle concentrations are dependent on indoor sources, penetration of outdoor particles, air change with outdoors, and deposition of particles on indoor surfaces as well as other loss mechanisms. Of these factors, few data are available on deposition of pa...

  20. Exposure to indoor tanning without burning and melanoma risk by sunburn history.

    PubMed

    Vogel, Rachel Isaksson; Ahmed, Rehana L; Nelson, Heather H; Berwick, Marianne; Weinstock, Martin A; Lazovich, DeAnn

    2014-07-01

    Indoor tanning is carcinogenic to humans. Individuals report that they tan indoors before planning to be in the sun to prevent sunburns, but whether skin cancer is subsequently reduced is unknown. Using a population-based case-control study, we calculated the association between melanoma and indoor tanning after excluding exposed participants reporting indoor tanning-related burns, stratified by their number of lifetime sunburns (0, 1-2, 3-5, >5). Confounding was addressed using propensity score analysis methods. All statistical tests were two-sided. We observed increased risk of melanoma across all sunburn categories for participants who had tanned indoors without burning compared with those who never tanned indoors, including those who reported zero lifetime sunburns (odds ratio = 3.87; 95% confidence interval = 1.68 to 8.91; P = .002). These data provide evidence that indoor tanning is a risk factor for melanoma even among persons who reported never experiencing burns from indoor tanning or outdoor sun exposure. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  1. Exposure to indoor tanning without burning and melanoma risk by sunburn history.

    PubMed

    Vogel, Rachel Isaksson; Ahmed, Rehana L; Nelson, Heather H; Berwick, Marianne; Weinstock, Martin A; Lazovich, DeAnn

    2014-06-01

    Indoor tanning is carcinogenic to humans. Individuals report that they tan indoors before planning to be in the sun to prevent sunburns, but whether skin cancer is subsequently reduced is unknown. Using a population-based case-control study, we calculated the association between melanoma and indoor tanning after excluding exposed participants reporting indoor tanning-related burns, stratified by their number of lifetime sunburns (0, 1-2, 3-5, >5). Confounding was addressed using propensity score analysis methods. All statistical tests were two-sided. We observed increased risk of melanoma across all sunburn categories for participants who had tanned indoors without burning compared with those who never tanned indoors, including those who reported zero lifetime sunburns (odds ratio = 3.87; 95% confidence interval = 1.68 to 8.91; P = .002). These data provide evidence that indoor tanning is a risk factor for melanoma even among persons who reported never experiencing burns from indoor tanning or outdoor sun exposure. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  2. Fungal microcolonies on indoor surfaces — an explanation for the base-level fungal spore counts in indoor air

    NASA Astrophysics Data System (ADS)

    Pasanen, A.-L.; Heinonen-Tanski, H.; Kalliokoski, P.; Jantunen, M. J.

    In the subarctic winter, fungal spores are found in indoor air even when outdoor spore levels are very low. The results of this study support an explanation that some indoor airborne fungal spores are derived from unnoticeable fungal microcolonies, which may develop on temporarily wet surfaces. Laboratory experiments on Penicillium verrucosum indicated that the fungus germinated on new wallpaper very quickly (about half an hour) under moist conditions. Hyphal growth and sporulation of the fungus on moist wallpaper occured within one day of incubation. In gravity-settling tape samples from occasionally wet surfaces in a suburban home, large spore aggregates, hyphal fragments with some spores and spores in the germination stage were found, indicating fungal growth. These experiments showed that fungal microcolonies can develop within a week on occasionally wet indoor surfaces.

  3. Association Between Indoor Tanning and Melanoma in Younger Men and Women.

    PubMed

    Lazovich, DeAnn; Isaksson Vogel, Rachel; Weinstock, Martin A; Nelson, Heather H; Ahmed, Rehana L; Berwick, Marianne

    2016-03-01

    In the United States and Minnesota, melanoma incidence is rising more steeply among women than men younger than 50 years. To our knowledge, no study has examined age- and sex-specific associations between indoor tanning and melanoma to determine if these trends could be due to greater indoor tanning use among younger women. To examine associations between indoor tanning and melanoma among men and women younger than 50 years. Population-based case-control study conducted in Minnesota of 681 patients (465 [68.3%] women) diagnosed as having melanoma between 2004 and 2007, and 654 controls (446 [68.2%] women), ages 25 to 49 years. Indoor tanning, defined as any use, first age of use, and total sessions. Crude and adjusted odds ratios (ORs) and 95% CIs were calculated for melanoma in relation to indoor tanning exposure for men and women by diagnosis or reference age (<30, 30-39, 40-49 years). Sex-specific associations for indoor tanning and melanoma by anatomic site were examined. Compared with women aged 40 to 49 years, women younger than 40 years initiated indoor tanning at a younger age (16 vs 25 years, P < .001) and reported more frequent indoor tanning (median number of sessions, 100 vs 40, P < .001). Women younger than 30 years were 6 times more likely to be in the case than the control group if they tanned indoors (crude OR, 6.0; 95% CI, 1.3-28.5). Odds ratios were also significantly elevated among women, ages 30 to 49 years (adjusted OR, 3.5; 95% CI, 1.2-9.7 for women 30-39 years; adjusted OR, 2.3; 95% CI, 1.4-3.6 for women 40-49 years); a dose response was observed among women regardless of age. Among men, results by age were inconsistent. The strongest OR for indoor tanning by anatomic site was for melanomas arising on the trunk of women (adjusted OR, 3.7; 95% CI, 1.9-7.2). Indoor tanning is a likely factor for the steeper increase in melanoma rates in the United States among younger women compared with men, given the timing of when women initiated indoor

  4. Are Cockroaches an Important Source of Indoor Endotoxins?

    PubMed

    Lai, Ka Man

    2017-01-18

    Endotoxins are common indoor biocontaminants. Their levels have been shown to link to many sources and factors. One of them is cockroach infestation but the role of cockroaches and contamination mechanisms are unclear. We hypothesized that not only is cockroach infestation a sign of poor hygiene, but it also contributes to indoor endotoxins via fecal contamination. In this study, different cockroach species were caught in homes. The endotoxin and allergen levels and their ratios in cockroach feces were determined. To estimate the amount of indoor endotoxins that originated from cockroaches, a new approach of using these new cockroach endotoxin and allergen ratios to compare with environmental data was employed. We found that Supella (S.) longipalpa , Periplaneta (P.) australasiae , and Blattella (B.) germanica were dominant in homes. On average, P. australasiae feces had a higher level but greater variation of endotoxins. B. germanica feces had the highest levels of allergens measured. Depending on environmental bacterial load and the type of cockroaches present, cockroach endotoxins in the environment may vary greatly. Cockroaches directly contribute to indoor endotoxins rather than just being a sign of poor hygiene. The type and extent of cockroach infestation should be taken into consideration when assessing and remediating indoor endotoxin contamination.

  5. Are Cockroaches an Important Source of Indoor Endotoxins?

    PubMed Central

    Lai, Ka Man

    2017-01-01

    Endotoxins are common indoor biocontaminants. Their levels have been shown to link to many sources and factors. One of them is cockroach infestation but the role of cockroaches and contamination mechanisms are unclear. We hypothesized that not only is cockroach infestation a sign of poor hygiene, but it also contributes to indoor endotoxins via fecal contamination. In this study, different cockroach species were caught in homes. The endotoxin and allergen levels and their ratios in cockroach feces were determined. To estimate the amount of indoor endotoxins that originated from cockroaches, a new approach of using these new cockroach endotoxin and allergen ratios to compare with environmental data was employed. We found that Supella (S.) longipalpa, Periplaneta (P.) australasiae, and Blattella (B.) germanica were dominant in homes. On average, P. australasiae feces had a higher level but greater variation of endotoxins. B. germanica feces had the highest levels of allergens measured. Depending on environmental bacterial load and the type of cockroaches present, cockroach endotoxins in the environment may vary greatly. Cockroaches directly contribute to indoor endotoxins rather than just being a sign of poor hygiene. The type and extent of cockroach infestation should be taken into consideration when assessing and remediating indoor endotoxin contamination. PMID:28106812

  6. Indoor Air Quality Building Education and Assessment Model Forms

    EPA Pesticide Factsheets

    The Indoor Air Quality Building Education and Assessment Model (I-BEAM) is a guidance tool designed for use by building professionals and others interested in indoor air quality in commercial buildings.

  7. PRIMAL: Page Rank-Based Indoor Mapping and Localization Using Gene-Sequenced Unlabeled WLAN Received Signal Strength

    PubMed Central

    Zhou, Mu; Zhang, Qiao; Xu, Kunjie; Tian, Zengshan; Wang, Yanmeng; He, Wei

    2015-01-01

    Due to the wide deployment of wireless local area networks (WLAN), received signal strength (RSS)-based indoor WLAN localization has attracted considerable attention in both academia and industry. In this paper, we propose a novel page rank-based indoor mapping and localization (PRIMAL) by using the gene-sequenced unlabeled WLAN RSS for simultaneous localization and mapping (SLAM). Specifically, first of all, based on the observation of the motion patterns of the people in the target environment, we use the Allen logic to construct the mobility graph to characterize the connectivity among different areas of interest. Second, the concept of gene sequencing is utilized to assemble the sporadically-collected RSS sequences into a signal graph based on the transition relations among different RSS sequences. Third, we apply the graph drawing approach to exhibit both the mobility graph and signal graph in a more readable manner. Finally, the page rank (PR) algorithm is proposed to construct the mapping from the signal graph into the mobility graph. The experimental results show that the proposed approach achieves satisfactory localization accuracy and meanwhile avoids the intensive time and labor cost involved in the conventional location fingerprinting-based indoor WLAN localization. PMID:26404274

  8. GRP1 PH Domain, Like AKT1 PH Domain, Possesses a Sentry Glutamate Residue Essential for Specific Targeting to Plasma Membrane PI(3,4,5)P3

    PubMed Central

    Pilling, Carissa; Landgraf, Kyle E.; Falke, Joseph J.

    2011-01-01

    During the appearance of the signaling lipid PI(3,4,5)P3, an important subset of pleckstrin homology (PH) domains target signaling proteins to the plasma membrane. To ensure proper pathway regulation, such PI(3,4,5)P3-specific PH domains must exclude the more prevalant, constitutive plasma membrane lipid PI(4,5)P2 and bind the rare PI(3,4,5)P3 target lipid with sufficiently high affinity. Our previous study of the E17K mutant of protein kinase B (AKT1) PH domain, together with evidence from Carpten et al (1), revealed that the native AKT1 E17 residue serves as a sentry glutamate that excludes PI(4,5)P2, thereby playing an essential role in specific PI(3,4,5)P3 targeting (2). The sentry glutamate hypothesis proposes that an analogous sentry glutamate residue is a widespread feature of PI(3,4,5)P3-specific PH domains, and that charge reversal mutation at the sentry glutamate position will yield both increased PI(4,5)P2 affinity and constitutive plasma membrane targeting. To test this hypothesis the present study investigates the E345 residue, a putative sentry glutamate, of General Receptor for Phosphoinositides 1 (GRP1) PH domain. The results show that incorporation of the E345K charge reversal mutation into GRP1 PH domain enhances PI(4,5)P2 affinity 8-fold and yields constitutive plasma membrane targeting in cells, reminiscent of the effects of the E17K mutation in AKT1 PH domain. Hydrolysis of plasma membrane PI(4,5)P2 releases E345K GRP1 PH domain into the cytoplasm and the efficiency of this release increases when target Arf6 binding is disrupted. Overall, the findings provide strong support for the sentry glutamate hypothesis and suggest that the GRP1 E345K mutation will be linked to changes in cell physiology and human pathologies, as demonstrated for AKT1 E17K (1, 3). Analysis of available PH domain structures suggests that a lone glutamate residue (or, in some cases an aspartate) is a common, perhaps ubiquitous, feature of PI(3,4,5)P3-specific binding

  9. D Modelling of AN Indoor Space Using a Rotating Stereo Frame Camera System

    NASA Astrophysics Data System (ADS)

    Kang, J.; Lee, I.

    2016-06-01

    Sophisticated indoor design and growing development in urban architecture make indoor spaces more complex. And the indoor spaces are easily connected to public transportations such as subway and train stations. These phenomena allow to transfer outdoor activities to the indoor spaces. Constant development of technology has a significant impact on people knowledge about services such as location awareness services in the indoor spaces. Thus, it is required to develop the low-cost system to create the 3D model of the indoor spaces for services based on the indoor models. In this paper, we thus introduce the rotating stereo frame camera system that has two cameras and generate the indoor 3D model using the system. First, select a test site and acquired images eight times during one day with different positions and heights of the system. Measurements were complemented by object control points obtained from a total station. As the data were obtained from the different positions and heights of the system, it was possible to make various combinations of data and choose several suitable combinations for input data. Next, we generated the 3D model of the test site using commercial software with previously chosen input data. The last part of the processes will be to evaluate the accuracy of the generated indoor model from selected input data. In summary, this paper introduces the low-cost system to acquire indoor spatial data and generate the 3D model using images acquired by the system. Through this experiments, we ensure that the introduced system is suitable for generating indoor spatial information. The proposed low-cost system will be applied to indoor services based on the indoor spatial information.

  10. Indoor Air Quality in Schools: Clean Air Is Good Business.

    ERIC Educational Resources Information Center

    Guarneiri, Michele A.

    2003-01-01

    Describes the effect of poor indoor air quality (IAQ) on student health, the cost of safeguarding good IAQ, the cause of poor IAQ in schools, how to tell whether a school has an IAQ problem, and how the U.S. Environmental Protection Agency can help schools improve indoor air quality though the use of their free "Indoor Air Quality Tools for…

  11. Indoor unit for electric heat pump

    DOEpatents

    Draper, Robert; Lackey, Robert S.; Fagan, Jr., Thomas J.; Veyo, Stephen E.; Humphrey, Joseph R.

    1984-01-01

    An indoor unit for an electric heat pump is provided in modular form including a refrigeration module 10, an air mover module 12, and a resistance heat package module 14, the refrigeration module including all of the indoor refrigerant circuit components including the compressor 36 in a space adjacent the heat exchanger 28, the modules being adapted to be connected to air flow communication in several different ways as shown in FIGS. 4-7 to accommodate placement of the unit in various orientations.

  12. Quantitative filter forensics for indoor particle sampling.

    PubMed

    Haaland, D; Siegel, J A

    2017-03-01

    Filter forensics is a promising indoor air investigation technique involving the analysis of dust which has collected on filters in central forced-air heating, ventilation, and air conditioning (HVAC) or portable systems to determine the presence of indoor particle-bound contaminants. In this study, we summarize past filter forensics research to explore what it reveals about the sampling technique and the indoor environment. There are 60 investigations in the literature that have used this sampling technique for a variety of biotic and abiotic contaminants. Many studies identified differences between contaminant concentrations in different buildings using this technique. Based on this literature review, we identified a lack of quantification as a gap in the past literature. Accordingly, we propose an approach to quantitatively link contaminants extracted from HVAC filter dust to time-averaged integrated air concentrations. This quantitative filter forensics approach has great potential to measure indoor air concentrations of a wide variety of particle-bound contaminants. Future studies directly comparing quantitative filter forensics to alternative sampling techniques are required to fully assess this approach, but analysis of past research suggests the enormous possibility of this approach. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. [Health impact of indoor mineral particle pollution].

    PubMed

    Vincent, M; Chemarin, C

    2011-04-01

    Mineral particle air pollution consists of both atmospheric pollution and indoor pollution. Indoor pollution comes from household products, cosmetics, combustion used to heat homes or cook food, smoking, hobbies or odd jobs. There is strong evidence that acute respiratory infections in children and chronic obstructive pulmonary disease in women are associated with indoor biomass smoke. Detailed questioning is essential to identify at risk activities and sampling of airborne particles may help with the identification of pollution risks. Particle elimination depends on the standard of ventilation of the indoor environment. Five per cent of French homes have levels of pollution greater than 180 μg/m³ for PM 10 and 2% for PM 2.5. The principal mineral particle air pollutants are probably silica, talc, asbestos and carbon, whereas tobacco smoke leads to exposure to various ultrafine particles. The toxicity of these particles could be more related to surface exchange than to density. Tissue measurements by electron microscopy and microanalysis of particle samples may identify an uptake of particles similar to those in the environmental sample. Copyright © 2011. Published by Elsevier Masson SAS.

  14. Perceptions of tanning risk among melanoma patients with a history of indoor tanning.

    PubMed

    Nergard-Martin, Jennifer; Caldwell, Chauncey; Barr, Morgan; Dellavalle, Robert P; Solomon, James A

    2018-01-01

    A new US Food and Drug Administration (FDA) regulation classified tanning beds as class II, requiring indoor tanning facilities to inform users of the risk of skin cancer in efforts to reverse the growing trend in indoor tanning. However, little is known from the patient's perspective on whether knowledge of the risk of skin cancer development is a deterrent to indoor tanning. There also is conflicting literature regarding the relationship among frequency of indoor tanning, age at onset of melanoma diagnosis, and characteristics of diagnosis in melanoma patients with a history of indoor tanning. An international survey was conducted in patients 18 years and older who self-reported being diagnosed with melanoma after indoor tanning. The purpose of this study was to investigate the patients' perspective on indoor-tanning behaviors as associated with the severity of their melanomas and the time frame in which they were diagnosed as well as their perceived views on the safety of indoor tanning and the frequency in which they continue to tan indoors.

  15. Modeling indoor particulate exposures in inner city school classrooms

    PubMed Central

    Gaffin, Jonathan M.; Petty, Carter R.; Hauptman, Marissa; Kang, Choong-Min; Wolfson, Jack M.; Awad, Yara Abu; Di, Qian; Lai, Peggy S.; Sheehan, William J.; Baxi, Sachin; Coull, Brent A.; Schwartz, Joel D.; Gold, Diane R.; Koutrakis, Petros; Phipatanakul, Wanda

    2016-01-01

    Outdoor air pollution penetrates buildings and contributes to total indoor exposures. We investigated the relationship of indoor to outdoor particulate matter in inner-city school classrooms. The School Inner City Asthma Study investigates the effect of classroom-based environmental exposures on students with asthma in the northeast United States. Mixed-effects linear models were used to determine the relationships between indoor PM2.5 and BC and their corresponding outdoor concentrations, and to develop a model for predicting exposures to these pollutants. The indoor-outdoor sulfur ratio was used as an infiltration factor of outdoor fine particles. Weeklong concentrations of PM2.5 and BC in 199 samples from 136 classrooms (30 school buildings) were compared to those measured at a central monitoring site averaged over the same timeframe. Mixed effects regression models found significant random intercept and slope effects, which indicate that: 1) there are important PM2.5 sources in classrooms; 2) the penetration of outdoor PM2.5 particles varies by school, and 3) the site-specific outside PM2.5 levels (inferred by the models) differ from those observed at the central monitor site. Similar results were found for BC except for lack of indoor sources. The fitted predictions from the sulfur-adjusted models were moderately predictive of observed indoor pollutant levels (Out of sample correlations: PM2.5: r2 = 0.68, BC; r2 = 0.61). Our results suggest that PM2.5 has important classroom sources, which vary by school. Furthermore, using these mixed effects models, classroom exposures can be accurately predicted for dates when central site measures are available but indoor measures are not available. PMID:27599884

  16. Defining indoor heat thresholds for health in the UK.

    PubMed

    Anderson, Mindy; Carmichael, Catriona; Murray, Virginia; Dengel, Andy; Swainson, Michael

    2013-05-01

    It has been recognised that as outdoor ambient temperatures increase past a particular threshold, so do mortality/morbidity rates. However, similar thresholds for indoor temperatures have not yet been identified. Due to a warming climate, the non-sustainability of air conditioning as a solution, and the desire for more energy-efficient airtight homes, thresholds for indoor temperature should be defined as a public health issue. The aim of this paper is to outline the need for indoor heat thresholds and to establish if they can be identified. Our objectives include: describing how indoor temperature is measured; highlighting threshold measurements and indices; describing adaptation to heat; summary of the risk of susceptible groups to heat; reviewing the current evidence on the link between sleep, heat and health; exploring current heat and health warning systems and thresholds; exploring the built environment and the risk of overheating; and identifying the gaps in current knowledge and research. A global literature search of key databases was conducted using a pre-defined set of keywords to retrieve peer-reviewed and grey literature. The paper will apply the findings to the context of the UK. A summary of 96 articles, reports, government documents and textbooks were analysed and a gap analysis was conducted. Evidence on the effects of indoor heat on health implies that buildings are modifiers of the effect of climate on health outcomes. Personal exposure and place-based heat studies showed the most significant correlations between indoor heat and health outcomes. However, the data are sparse and inconclusive in terms of identifying evidence-based definitions for thresholds. Further research needs to be conducted in order to provide an evidence base for threshold determination. Indoor and outdoor heat are related but are different in terms of language and measurement. Future collaboration between the health and building sectors is needed to develop a common

  17. Outdoor and indoor UFP in primary schools across Barcelona.

    PubMed

    Reche, C; Viana, M; Rivas, I; Bouso, L; Àlvarez-Pedrerol, M; Alastuey, A; Sunyer, J; Querol, X

    2014-09-15

    Indoor and outdoor measurements of real-time ultrafine particles (UFP; N10-700 in this study) number concentration and average diameter were collected twice at 39 primary schools located in Barcelona (Spain), with classrooms naturally ventilated under warm weather conditions. Simultaneous outdoor N concentration measurements at schools under different traffic exposures showed the important role of this source, with higher levels by 40% on average at schools near heavy traffic, highlighting thus the increased exposure of children due to urban planning decisions. A well-defined spatial pattern of outdoor UFP levels was observed. Midday increases in outdoor N levels mainly attributed to nucleation processes have been recorded both at high and low temperatures in several of the outdoor school sites (increasing levels by 15%-70%). The variation of these increases also followed a characteristic spatial pattern, pointing at schools' location as a key variable in terms of UFP load owing to the important contribution of traffic emissions. Indoor N concentrations were to some extent explained by outdoor N concentrations during school hours, together with average temperatures, related with natural ventilation. Outdoor midday increases were generally mimicked by indoor N concentrations, especially under warm temperatures. At specific cases, indoor concentrations during midday were 30%-40% higher than outdoor. The time scale of these observations evidenced the possible role of: a) secondary particle formation enhanced by indoor precursors or conditions, maybe related with surface chemistry reactions mediated by O3, and/or b) UFP from cooking activities. Significant indoor N increases were detected after school hours, probably associated with cleaning activities, resulting in indoor N concentrations up to 3 times higher than those in outdoor. A wide variability of indoor/outdoor ratios of N concentrations and mean UFP sizes was detected among schools and measurement periods

  18. Winter Weather: Indoor Safety

    MedlinePlus

    ... Use flashlights or lanterns instead. Never use an electric generator or a gas or charcoal grill indoors. ... heater. Make sure that the cord of an electric space heater is not a tripping hazard but ...

  19. Improving Indoor Air Quality

    EPA Pesticide Factsheets

    Usually the most effective way to improve indoor air quality is to eliminate individual sources of pollution or to reduce their emissions. Some sources, like those that contain asbestos, can be sealed or enclosed.

  20. a Review of Recent Research in Indoor Modelling & Mapping

    NASA Astrophysics Data System (ADS)

    Gunduz, M.; Isikdag, U.; Basaraner, M.

    2016-06-01

    Indoor modeling and mapping has been an active area of research in last 20 years in order to tackle the problems related to positioning and tracking of people and objects indoors, and provides many opportunities for several domains ranging from emergency response to logistics in micro urban spaces. The outputs of recent research in the field have been presented in several scientific publications and events primarily related to spatial information science and technology. This paper summarizes the outputs of last 10 years of research on indoor modeling and mapping within a proper classification which covers 7 areas, i.e. Information Acquisition by Sensors, Model Definition, Model Integration, Indoor Positioning and LBS, Routing & Navigation Methods, Augmented and Virtual Reality Applications, and Ethical Issues. Finally, the paper outlines the current and future research directions and concluding remarks.

  1. Youth indoor tanning and skin cancer prevention: lessons from tobacco control.

    PubMed

    Seidenberg, Andrew B; Mahalingam-Dhingra, Aditya; Weinstock, Martin A; Sinclair, Craig; Geller, Alan C

    2015-02-01

    Youth use of ultraviolet-emitting indoor tanning beds represents a present and emerging public health crisis. Nearly 30% of white female high school students report tanning indoors, and a quarter of high school tanners have used a tanning bed more than 20 times in the past year. Despite the significant health risks of tanning beds, including potentially deadly melanoma and eye problems, limited actions have been taken in the U.S. to protect youth. Tobacco control policies and campaigns, which have sharply reduced youth smoking, may provide a useful framework to control indoor tanning among young people. This article describes several evidence-based tobacco control strategies with potential applicability to indoor tanning within the context of the U.S. Further, current tobacco control policies and current indoor tanning policies in the U.S. are compared, and recommendations on how to curtail youth indoor tanning are discussed. Copyright © 2015 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  2. Modeling Human Exposure to Indoor Contaminants: External Source to Body Tissues.

    PubMed

    Webster, Eva M; Qian, Hua; Mackay, Donald; Christensen, Rebecca D; Tietjen, Britta; Zaleski, Rosemary

    2016-08-16

    Information on human indoor exposure is necessary to assess the potential risk to individuals from many chemicals of interest. Dynamic indoor and human physicologically based pharmacokinetic (PBPK) models of the distribution of nonionizing, organic chemical concentrations in indoor environments resulting in delivered tissue doses are developed, described and tested. The Indoor model successfully reproduced independently measured, reported time-dependent air concentrations of chloroform released during showering and of 2-butyoxyethanol following use of a volatile surface cleaner. The Indoor model predictions were also comparable to those from a higher tier consumer model (ConsExpo 4.1) for the surface cleaner scenario. The PBPK model successful reproduced observed chloroform exhaled air concentrations resulting from an inhalation exposure. Fugacity based modeling provided a seamless description of the partitioning, fluxes, accumulation and release of the chemical in indoor media and tissues of the exposed subject. This has the potential to assist in health risk assessments, provided that appropriate physical/chemical property, usage characteristics, and toxicological information are available.

  3. Geomagnetism-Aided Indoor Wi-Fi Radio-Map Construction via Smartphone Crowdsourcing.

    PubMed

    Li, Wen; Wei, Dongyan; Lai, Qifeng; Li, Xianghong; Yuan, Hong

    2018-05-08

    Wi-Fi radio-map construction is an important phase in indoor fingerprint localization systems. Traditional methods for Wi-Fi radio-map construction have the problems of being time-consuming and labor-intensive. In this paper, an indoor Wi-Fi radio-map construction method is proposed which utilizes crowdsourcing data contributed by smartphone users. We draw indoor pathway map and construct Wi-Fi radio-map without requiring manual site survey, exact floor layout and extra infrastructure support. The key novelty is that it recognizes road segments from crowdsourcing traces by a cluster based on magnetism sequence similarity and constructs an indoor pathway map with Wi-Fi signal strengths annotated on. Through experiments in real world indoor areas, the method is proved to have good performance on magnetism similarity calculation, road segment clustering and pathway map construction. The Wi-Fi radio maps constructed by crowdsourcing data are validated to provide competitive indoor localization accuracy.

  4. Geomagnetism-Aided Indoor Wi-Fi Radio-Map Construction via Smartphone Crowdsourcing

    PubMed Central

    Li, Wen; Wei, Dongyan; Lai, Qifeng; Li, Xianghong; Yuan, Hong

    2018-01-01

    Wi-Fi radio-map construction is an important phase in indoor fingerprint localization systems. Traditional methods for Wi-Fi radio-map construction have the problems of being time-consuming and labor-intensive. In this paper, an indoor Wi-Fi radio-map construction method is proposed which utilizes crowdsourcing data contributed by smartphone users. We draw indoor pathway map and construct Wi-Fi radio-map without requiring manual site survey, exact floor layout and extra infrastructure support. The key novelty is that it recognizes road segments from crowdsourcing traces by a cluster based on magnetism sequence similarity and constructs an indoor pathway map with Wi-Fi signal strengths annotated on. Through experiments in real world indoor areas, the method is proved to have good performance on magnetism similarity calculation, road segment clustering and pathway map construction. The Wi-Fi radio maps constructed by crowdsourcing data are validated to provide competitive indoor localization accuracy. PMID:29738454

  5. Indoor Navigation from Point Clouds: 3d Modelling and Obstacle Detection

    NASA Astrophysics Data System (ADS)

    Díaz-Vilariño, L.; Boguslawski, P.; Khoshelham, K.; Lorenzo, H.; Mahdjoubi, L.

    2016-06-01

    In the recent years, indoor modelling and navigation has become a research of interest because many stakeholders require navigation assistance in various application scenarios. The navigational assistance for blind or wheelchair people, building crisis management such as fire protection, augmented reality for gaming, tourism or training emergency assistance units are just some of the direct applications of indoor modelling and navigation. Navigational information is traditionally extracted from 2D drawings or layouts. Real state of indoors, including opening position and geometry for both windows and doors, and the presence of obstacles is commonly ignored. In this work, a real indoor-path planning methodology based on 3D point clouds is developed. The value and originality of the approach consist on considering point clouds not only for reconstructing semantically-rich 3D indoor models, but also for detecting potential obstacles in the route planning and using these for readapting the routes according to the real state of the indoor depictured by the laser scanner.

  6. Dermal bioaccessibility of flame retardants from indoor dust and the influence of topically applied cosmetics.

    PubMed

    Pawar, Gopal; Abdallah, Mohamed Abou-Elwafa; de Sáa, Eugenia Villaverde; Harrad, Stuart

    2017-01-01

    Despite extensive literature on their potential adverse health effects, there is a lack of information on human dermal exposure to organic flame retardant chemicals (FRs). This study applies an in vitro physiologically based extraction test to provide new insights into the dermal bioaccessibility of various FRs from indoor dust to synthetic sweat/sebum mixture (SSSM). The bioaccessible fractions of α-, β- and γ-hexabromocyclododecane (HBCD) and tetrabromobisphenol A (TBBPA) to 1:1 (sweat/sebum) mixture were 41%, 47%, 50% and 40%, respectively. For Tris-2-chloroethyl phosphate (TCEP), tris (1-chloro-2-propyl) phosphate (TCIPP) and tris-1,3-dichloropropyl phosphate (TDCIPP), bioaccessible fractions were 10%, 17% and 19%. Composition of the SSSM and compound-specific physicochemical properties were the major factors influencing the bioaccessibility of target FRs. Except for TBBPA, the presence of cosmetics (moisturising cream, sunscreen lotion, body spray and shower gel) had a significant effect (P<0.05) on the bioaccessibility of the studied FRs. The presence of cosmetics decreased the bioaccessibility of HBCDs from indoor dust, whereas shower gel and sunscreen lotion enhanced the bioaccessibility of target PFRs. Our bioaccessibility data were applied to estimate the internal exposure of UK adults and toddlers to the target FRs via dermal contact with dust. Our worst-case scenario exposure estimates fell far below available health-based limit values for TCEP, TCIPP and TDCIPP. However, future research may erode the margin of safety for these chemicals.

  7. Indoor phthalate concentration in residential apartments in Chongqing, China: Implications for preschool children's exposure and risk assessment

    NASA Astrophysics Data System (ADS)

    Bu, Zhongming; Zhang, Yinping; Mmereki, Daniel; Yu, Wei; Li, Baizhan

    2016-02-01

    Six phthalates - dimethyl phthalate (DMP), diethyl phthalate (DEP), di(isobutyl) phthalate (DiBP), di(n-butyl) phthalate (DnBP), butyl benzyl phthalate (BBzP) and di(2-ethylhexyl) phthalate (DEHP) - in indoor gas-phase and dust samples were measured in thirty residential apartments for the first time in Chongqing, China. Monte-Carlo simulation was used to estimate preschool children's exposure via inhalation, non-dietary ingestion and dermal absorption based on gas-phase and dust concentrations. Risk assessment was evaluated by comparing the modeled exposure doses with child-specific benchmarks specified in California's Proposition 65. The detection frequency for all the targeted phthalates was more than 80% except for BBzP. DMP was the most predominant compound in the gas-phase (median = 0.91 μg/m3 and 0.82 μg/m3 in living rooms and bedrooms, respectively), and DEHP was the most predominant compound in the dust samples (median = 1543 μg/g and 1450 μg/g in living rooms and bedrooms, respectively). Correlation analysis suggests that indoor DiBP and DnBP might come from the same emission sources. The simulations showed that the median DEHP daily intake was 3.18-4.28 μg/day/kg-bw in all age groups, suggesting that it was the greatest of the targeted phthalates. The risk assessment indicated that the exposure doses of DnBP and DEHP exceeded the child-specific benchmarks in more than 90% of preschool children in Chongqing. Therefore, from a children's health perspective, efforts should focus on controlling indoor phthalate concentrations and exposures.

  8. Channel Model Optimization with Reflection Residual Component for Indoor MIMO-VLC System

    NASA Astrophysics Data System (ADS)

    Chen, Yong; Li, Tengfei; Liu, Huanlin; Li, Yichao

    2017-12-01

    A fast channel modeling method is studied to solve the problem of reflection channel gain for multiple input multiple output-visible light communications (MIMO-VLC) in the paper. For reducing the computational complexity when associating with the reflection times, no more than 3 reflections are taken into consideration in VLC. We think that higher order reflection link consists of corresponding many times line of sight link and firstly present reflection residual component to characterize higher reflection (more than 2 reflections). We perform computer simulation results for point-to-point channel impulse response, receiving optical power and receiving signal to noise ratio. Based on theoretical analysis and simulation results, the proposed method can effectively reduce the computational complexity of higher order reflection in channel modeling.

  9. Influenza transmission during extreme indoor conditions in a low-resource tropical setting

    NASA Astrophysics Data System (ADS)

    Tamerius, James; Ojeda, Sergio; Uejio, Christopher K.; Shaman, Jeffrey; Lopez, Brenda; Sanchez, Nery; Gordon, Aubree

    2017-04-01

    Influenza transmission occurs throughout the planet across wide-ranging environmental conditions. However, our understanding of the environmental factors mediating transmission is evaluated using outdoor environmental measurements, which may not be representative of the indoor conditions where influenza is transmitted. In this study, we examined the relationship between indoor environment and influenza transmission in a low-resource tropical population. We used a case-based ascertainment design to enroll 34 households with a suspected influenza case and then monitored households for influenza, while recording indoor temperature and humidity data in each household. We show that the indoor environment is not commensurate with outdoor conditions and that the relationship between indoor and outdoor conditions varies significantly across homes. We also show evidence of influenza transmission in extreme indoor environments. Specifically, our data suggests that indoor environments averaged 29 °C, 18 g/kg specific humidity, and 68 % relative humidity across 15 transmission events observed. These indoor settings also exhibited significant temporal variability with temperatures as high as 39 °C and specific and relative humidity increasing to 22 g/kg and 85 %, respectively, during some transmission events. However, we were unable to detect differences in the transmission efficiency by indoor temperature or humidity conditions. Overall, these results indicate that laboratory studies investigating influenza transmission and virus survival should increase the range of environmental conditions that they assess and that observational studies investigating the relationship between environment and influenza activity should use caution using outdoor environmental measurements since they can be imprecise estimates of the conditions that mediate transmission indoors.

  10. Influenza transmission during extreme indoor conditions in a low-resource tropical setting.

    PubMed

    Tamerius, James; Ojeda, Sergio; Uejio, Christopher K; Shaman, Jeffrey; Lopez, Brenda; Sanchez, Nery; Gordon, Aubree

    2017-04-01

    Influenza transmission occurs throughout the planet across wide-ranging environmental conditions. However, our understanding of the environmental factors mediating transmission is evaluated using outdoor environmental measurements, which may not be representative of the indoor conditions where influenza is transmitted. In this study, we examined the relationship between indoor environment and influenza transmission in a low-resource tropical population. We used a case-based ascertainment design to enroll 34 households with a suspected influenza case and then monitored households for influenza, while recording indoor temperature and humidity data in each household. We show that the indoor environment is not commensurate with outdoor conditions and that the relationship between indoor and outdoor conditions varies significantly across homes. We also show evidence of influenza transmission in extreme indoor environments. Specifically, our data suggests that indoor environments averaged 29 °C, 18 g/kg specific humidity, and 68 % relative humidity across 15 transmission events observed. These indoor settings also exhibited significant temporal variability with temperatures as high as 39 °C and specific and relative humidity increasing to 22 g/kg and 85 %, respectively, during some transmission events. However, we were unable to detect differences in the transmission efficiency by indoor temperature or humidity conditions. Overall, these results indicate that laboratory studies investigating influenza transmission and virus survival should increase the range of environmental conditions that they assess and that observational studies investigating the relationship between environment and influenza activity should use caution using outdoor environmental measurements since they can be imprecise estimates of the conditions that mediate transmission indoors.

  11. Medical diagnostics for indoor mold exposure.

    PubMed

    Hurraß, Julia; Heinzow, Birger; Aurbach, Ute; Bergmann, Karl-Christian; Bufe, Albrecht; Buzina, Walter; Cornely, Oliver A; Engelhart, Steffen; Fischer, Guido; Gabrio, Thomas; Heinz, Werner; Herr, Caroline E W; Kleine-Tebbe, Jörg; Klimek, Ludger; Köberle, Martin; Lichtnecker, Herbert; Lob-Corzilius, Thomas; Merget, Rolf; Mülleneisen, Norbert; Nowak, Dennis; Rabe, Uta; Raulf, Monika; Seidl, Hans Peter; Steiß, Jens-Oliver; Szewszyk, Regine; Thomas, Peter; Valtanen, Kerttu; Wiesmüller, Gerhard A

    2017-04-01

    In April 2016, the German Society of Hygiene, Environmental Medicine and Preventative Medicine (Gesellschaft für Hygiene, Umweltmedizin und Präventivmedizin (GHUP)) together with other scientific medical societies, German and Austrian medical societies, physician unions and experts has provided an AWMF (Association of the Scientific Medical Societies) guideline 'Medical diagnostics for indoor mold exposure'. This guideline shall help physicians to advise and treat patients exposed indoors to mold. Indoor mold growth is a potential health risk, even without a quantitative and/or causal association between the occurrence of individual mold species and health effects. Apart from the allergic bronchopulmonary aspergillosis (ABPA) and the mycoses caused by mold, there is only sufficient evidence for the following associations between moisture/mold damages and different health effects: Allergic respiratory diseases, asthma (manifestation, progression, exacerbation), allergic rhinitis, exogenous allergic alveolitis and respiratory tract infections/bronchitis. In comparison to other environmental allergens, the sensitizing potential of molds is estimated to be low. Recent studies show a prevalence of sensitization of 3-10% in the total population of Europe. The evidence for associations to mucous membrane irritation and atopic eczema (manifestation, progression, exacerbation) is classified as limited or suspected. Inadequate or insufficient evidence for an association is given for COPD, acute idiopathic pulmonary hemorrhage in children, rheumatism/arthritis, sarcoidosis, and cancer. The risk of infections from indoor molds is low for healthy individuals. Only molds that are capable to form toxins can cause intoxications. The environmental and growth conditions and especially the substrate determine whether toxin formation occurs, but indoor air concentrations are always very low. In the case of indoor moisture/mold damages, everyone can be affected by odor effects and

  12. Performance Evaluation of Indoor Environment towards Sustainability for Higher Educational Buildings

    ERIC Educational Resources Information Center

    Khalil, Natasha; Husin, Husrul Nizam; Wahab, Lilawati Ab; Kamal, Kamarul Syahril; Mahat, Noorsaidi

    2011-01-01

    The indoor environmental factors considered in higher educational building must be determined in order to meet the user's requirement. Disruption of indoor environment may constitute to reduce occupants' efficiencies and their learning process and activities. But the question is, how to ensure that the provision of indoor environmental aspects…

  13. Indoor Air Quality Investigations on Particulate Matter, Carbonyls, and Tobacco Specific Nitrosamines

    NASA Astrophysics Data System (ADS)

    Frey, Sarah E.

    Americans spend upwards of 90% of their time indoors, hence indoor air quality (IAQ) and the impact of IAQ on human health is a major public health concern. IAQ can be negatively impacted by outdoor pollution infiltrating indoors, the emission of indoor pollutants, indoor atmospheric chemistry and poor ventilation. Energy saving measures like retrofits to seal the building envelope to prevent the leakage of heated or cooled air will impact IAQ. However, existing studies have been inconclusive as to whether increased energy efficiency is leading to detrimental IAQ. In this work, field campaigns were conducted in apartment homes in Phoenix, Arizona to evaluate IAQ as it relates to particulate matter (PM), carbonyls, and tobacco specific nitrosamines (TSNA). To investigate the impacts of an energy efficiency retrofit on IAQ, indoor and outdoor air quality sampling was carried out at Sunnyslope Manor, a city-subsidized senior living apartment complex. Measured indoor formaldehyde levels before the building retrofit exceeded reference exposure limits, but in the long term follow-up sampling, indoor formaldehyde decreased for the entire study population by a statistically significant margin. Indoor PM levels were dominated by fine particles and showed a statistically significant decrease in the long term follow-up sampling within certain resident subpopulations (i.e. residents who reported smoking and residents who had lived longer at the apartment complex). Additionally, indoor glyoxal and methylglyoxal exceeded outdoor concentrations, with methylglyoxal being more prevalent pre-retrofit than glyoxal, suggesting different chemical pathways are involved. Indoor concentrations reported are larger than previous studies. TSNAs, specifically N'-nitrosonornicotine (NNN), 4-(methyl-nitrosamino)-4-(3-pyridyl)-butanal (NNA) and 4-(methylnitrosoamino)-1-(3-pyridyl)-1-butanone (NNK) were evaluated post-retrofit at Sunnyslope Manor. Of the units tested, 86% of the smoking units and

  14. The impact of wood stove technology upgrades on indoor residential air quality

    NASA Astrophysics Data System (ADS)

    Allen, Ryan W.; Leckie, Sara; Millar, Gail; Brauer, Michael

    2009-12-01

    Fine particulate matter (PM 2.5) air pollution has been linked to adverse health impacts, and combustion sources including residential wood-burning may play an important role in some regions. Recent evidence suggests that indoor air quality may improve in homes where older, non-certified wood stoves are exchanged for lower emissions EPA-certified alternatives. As part of a wood stove exchange program in northern British Columbia, Canada, we sampled outdoor and indoor air at 15 homes during 6-day sampling sessions both before and after non-certified wood stoves were exchanged. During each sampling session two consecutive 3-day PM 2.5 samples were collected onto Teflon filters, which were weighed and analyzed for the wood smoke tracer levoglucosan. Residential PM 2.5 infiltration efficiencies ( Finf) were estimated from continuous light scattering measurements made with nephelometers, and estimates of Finf were used to calculate the outdoor- and indoor-generated contributions to indoor air. There was not a consistent relationship between stove technology and outdoor or indoor concentrations of PM 2.5 or levoglucosan. Mean Finf estimates were low and similar during pre- and post-exchange periods (0.32 ± 0.17 and 0.33 ± 0.17, respectively). Indoor sources contributed the majority (˜65%) of the indoor PM 2.5 concentrations, independent of stove technology, although low indoor-outdoor levoglucosan ratios (median ≤ 0.19) and low indoor PM 2.5-levoglucosan correlations ( r ≤ 0.19) suggested that wood smoke was not a major indoor PM 2.5 source in most of these homes. In summary, despite the potential for extensive wood stove exchange programs to reduce outdoor PM 2.5 concentrations in wood smoke-impacted communities, we did not find a consistent relationship between stove technology upgrades and indoor air quality improvements in homes where stoves were exchanged.

  15. Quality of indoor residential air and health

    PubMed Central

    Dales, Robert; Liu, Ling; Wheeler, Amanda J.; Gilbert, Nicolas L.

    2008-01-01

    About 90% of our time is spent indoors where we are exposed to chemical and biological contaminants and possibly to carcinogens. These agents may influence the risk of developing nonspecific respiratory and neurologic symptoms, allergies, asthma and lung cancer. We review the sources, health effects and control strategies for several of these agents. There are conflicting data about indoor allergens. Early exposure may increase or may decrease the risk of future sensitization. Reports of indoor moulds or dampness or both are consistently associated with increased respiratory symptoms but causality has not been established. After cigarette smoking, exposure to environmental tobacco smoke and radon are the most common causes of lung cancer. Homeowners can improve the air quality in their homes, often with relatively simple measures, which should provide health benefits. PMID:18625986

  16. Incremental impact upon malaria transmission of supplementing pyrethroid-impregnated long-lasting insecticidal nets with indoor residual spraying using pyrethroids or the organophosphate, pirimiphos methyl.

    PubMed

    Hamainza, Busiku; Sikaala, Chadwick H; Moonga, Hawela B; Chanda, Javan; Chinula, Dingani; Mwenda, Mulenga; Kamuliwo, Mulakwa; Bennett, Adam; Seyoum, Aklilu; Killeen, Gerry F

    2016-02-18

    Long-lasting, insecticidal nets (LLINs) and indoor residual spraying (IRS) are the most widely accepted and applied malaria vector control methods. However, evidence that incremental impact is achieved when they are combined remains limited and inconsistent. Fourteen population clusters of approximately 1000 residents each in Zambia's Luangwa and Nyimba districts, which had high pre-existing usage rates (81.7 %) of pyrethroid-impregnated LLINs were quasi-randomly assigned to receive IRS with either of two pyrethroids, namely deltamethrin [Wetable granules (WG)] and lambdacyhalothrin [capsule suspension (CS)], with an emulsifiable concentrate (EC) or CS formulation of the organophosphate pirimiphos methyl (PM), or with no supplementary vector control measure. Diagnostic positivity of patients tested for malaria by community health workers in these clusters was surveyed longitudinally over pre- and post-treatment periods spanning 29 months, over which the treatments were allocated and re-allocated in advance of three sequential rainy seasons. Supplementation of LLINs with PM CS offered the greatest initial level of protection against malaria in the first 3 months of application (incremental protective efficacy (IPE) [95 % confidence interval (CI)] = 0.63 [CI 0.57, 0.69], P < 0.001), followed by lambdacyhalothrin (IPE [95 % CI] = 0.31 [0.10, 0.47], P = 0.006) and PM EC (IPE, 0.23 [CI 0.15, 0.31], P < 0.001) and then by deltamethrin (IPE [95 % CI] = 0.19 [-0.01, 0.35], P = 0.064). Neither pyrethroid formulation provided protection beyond 3 months after spraying, but the protection provided by both PM formulations persisted undiminished for longer periods: 6 months for CS and 12 months for EC. The CS formulation of PM provided greater protection than the combined pyrethroid IRS formulations throughout its effective life IPE [95 % CI] = 0.79 [0.75, 0.83] over 6 months. The EC formulation of PM provided incremental protection for the first 3 months (IPE [95 % CI] = 0

  17. Computational Prediction of Hot Spot Residues

    PubMed Central

    Morrow, John Kenneth; Zhang, Shuxing

    2013-01-01

    Most biological processes involve multiple proteins interacting with each other. It has been recently discovered that certain residues in these protein-protein interactions, which are called hot spots, contribute more significantly to binding affinity than others. Hot spot residues have unique and diverse energetic properties that make them challenging yet important targets in the modulation of protein-protein complexes. Design of therapeutic agents that interact with hot spot residues has proven to be a valid methodology in disrupting unwanted protein-protein interactions. Using biological methods to determine which residues are hot spots can be costly and time consuming. Recent advances in computational approaches to predict hot spots have incorporated a myriad of features, and have shown increasing predictive successes. Here we review the state of knowledge around protein-protein interactions, hot spots, and give an overview of multiple in silico prediction techniques of hot spot residues. PMID:22316154

  18. Socio-economic costs of indoor air pollution: A tentative estimation for some pollutants of health interest in France.

    PubMed

    Boulanger, Guillaume; Bayeux, Thomas; Mandin, Corinne; Kirchner, Séverine; Vergriette, Benoit; Pernelet-Joly, Valérie; Kopp, Pierre

    2017-07-01

    An evaluation of the socio-economic costs of indoor air pollution can facilitate the development of appropriate public policies. For the first time in France, such an evaluation was conducted for six selected pollutants: benzene, trichloroethylene, radon, carbon monoxide, particles (PM 2.5 fraction), and environmental tobacco smoke (ETS). The health impacts of indoor exposure were either already available in published works or were calculated. For these calculations, two approaches were followed depending on the available data: the first followed the principles of quantitative health risk assessment, and the second was based on concepts and methods related to the health impact assessment. For both approaches, toxicological data and indoor concentrations related to each target pollutant were used. External costs resulting from mortality, morbidity (life quality loss) and production losses attributable to these health impacts were assessed. In addition, the monetary costs for the public were determined. Indoor pollution associated with the selected pollutants was estimated to have cost approximately €20 billion in France in 2004. Particles contributed the most to the total cost (75%), followed by radon. Premature death and the costs of the quality of life loss accounted for approximately 90% of the total cost. Despite the use of different methods and data, similar evaluations previously conducted in other countries yielded figures within the same order of magnitude. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Cryostat including heater to heat a target

    DOEpatents

    Pehl, Richard H.; Madden, Norman W.; Malone, Donald F.

    1990-01-01

    A cryostat is provided which comprises a vacuum vessel; a target disposed within the vacuum vessel; a heat sink disposed within the vacuum vesssel for absorbing heat from the detector; a cooling mechanism for cooling the heat sink; a cryoabsorption mechanism for cryoabsorbing residual gas within the vacuum vessel; and a heater for maintaining the target above a temperature at which the residual gas is cryoabsorbed in the course of cryoabsorption of the residual gas by the cryoabsorption mechanism.

  20. Indoor Trichoderma strains emitting peptaibols in guttation droplets.

    PubMed

    Castagnoli, E; Marik, T; Mikkola, R; Kredics, L; Andersson, M A; Salonen, H; Kurnitski, J

    2018-05-19

    The production of peptaibols, toxic secondary metabolites of Trichoderma, in the indoor environment is not well-documented. Here we investigated the toxicity of peptaibols in the guttation droplets and biomass of Trichoderma strains isolated from problematic buildings. Seven indoor-isolated strains of T. atroviride, T. trixiae, T. paraviridescens and T. citrinoviride were cultivated on malt extract agar, gypsum boards and paperboards. Their biomass extracts and guttation droplets were highly cytotoxic in resting and motile boar sperm cell assays and in inhibition of somatic cell proliferation assays. The toxins were identified with HPLC/ESI-MS/MS as trichorzianines, trilongins, trichostrigocins and trichostrigocin-like peptaibols. They exhibited toxicity profiles similar to the reference peptaibols alamethicin, trilongins, and trichorzianine TA IIIc purified from T. atroviride H1/226. Particular Trichoderma strains emitted the same peptaibols in both their biomasses and exudate droplets. The trilongin-producing T. citrinoviride SJ40 strain grew at 37°C. To our knowledge, this is the first report of indoor-isolated Trichoderma strains producing toxic peptaibols in their guttation droplets. This report proves that indoor isolates of Trichoderma release peptaibols in their guttation droplets. The presence of toxins in these type of exudates may serve as a mechanism of aerosol formation for nonvolatile toxins in the indoor air. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  1. PASSIVE/DIFFUSIVE SAMPLERS FOR PESTICIDES IN RESIDENTIAL INDOOR AIR

    EPA Science Inventory

    Pesticides applied indoors vaporize from treated surfaces (e.g., carpets and baseboards) resulting in elevated air concentrations that may persist for long periods after applications. Estimating long-term respiratory exposures to pesticide vapors in residential indoor environme...

  2. Addiction to indoor tanning: relation to anxiety, depression, and substance use.

    PubMed

    Mosher, Catherine E; Danoff-Burg, Sharon

    2010-04-01

    To assess the prevalence of addiction to indoor tanning among college students and its association with substance use and symptoms of anxiety and depression. Two written measures, the CAGE (Cut down, Annoyed, Guilty, Eye-opener) Questionnaire, used to screen for alcoholism, and the Diagnostic and Statistical Manual of Mental Disorders (Fourth Edition, Text Revision) (DSM-IV-TR) criteria for substance-related disorders, were modified to evaluate study participants for addiction to indoor tanning. Standardized self-report measures of anxiety, depression, and substance use also were administered. A large university (approximately 18 000 students) in the northeastern United States. A total of 421 college students were recruited from September through December 2006. Self-reported addiction to indoor tanning, substance use, and symptoms of anxiety and depression. Among 229 study participants who had used indoor tanning facilities, 90 (39.3%) met DSM-IV-TR criteria and 70 (30.6%) met CAGE criteria for addiction to indoor tanning. Students who met DSM-IV-TR and CAGE criteria for addiction to indoor tanning reported greater symptoms of anxiety and greater use of alcohol, marijuana, and other substances than those who did not meet these criteria. Depressive symptoms did not significantly vary by indoor tanning addiction status. Findings suggest that interventions to reduce skin cancer risk should address the addictive qualities of indoor tanning for a minority of individuals and the relationship of this behavior to other addictions and affective disturbance.

  3. Addiction to Indoor Tanning: Relations to Anxiety, Depression, and Substance Use

    PubMed Central

    Mosher, Catherine E.; Danoff-Burg, Sharon

    2013-01-01

    Objective To assess the prevalence of addiction to indoor tanning among college students and its association with substance use and symptoms of anxiety and depression. Design Two written measures, the CAGE (Cut down, Annoyed, Guilty, Eye-opener) Questionnaire, used to screen for alcoholism, and the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision (DSM-IV-TR) criteria for substance-related disorders, were modified to evaluate participants for addiction to indoor tanning. Standardized self-report measures of anxiety, depression, and substance use also were administered. Setting Large (i.e., approximately 18,000 students) university in the northeastern United States. Participants A total of 421 college students. Main Outcome Measures Self-reported addiction to indoor tanning, substance use, and symptoms of anxiety and depression. Results Among respondents who had used indoor tanning facilities (n = 229), 39% met DSM-IV-TR criteria and 31% met CAGE criteria for addiction to indoor tanning. Students who met DSM-IV-TR and CAGE criteria for addiction to indoor tanning reported greater symptoms of anxiety and greater use of alcohol, marijuana, and other substances than those who did not meet these criteria. Depressive symptoms did not significantly vary by indoor tanning addiction status. Conclusions Findings suggest that interventions to reduce skin cancer risk should address the addictive qualities of indoor tanning for a minority of individuals as well as the relationship of this behavior to other addictions and affective disturbance. PMID:20404230

  4. Risk-Based Treatment Targets for Onsite Non-Potable Water ...

    EPA Pesticide Factsheets

    This presentation presents risk-based enteric pathogen log reduction targets for non-potable and potable uses of a variety of alternative source waters (i.e., municipal wastewater, locally-collected greywater, rainwater, and stormwater). A probabilistic, forward Quantitative Microbial Risk Assessment (QMRA) was used to derive the pathogen log10 reduction targets (LRTs) that corresponded with an infection risk of either 10-4 per person per year (ppy) or 10-2 ppy. The QMRA accounted for variation in pathogen concentration and sporadic pathogen occurrence (when data were available) in source waters for reference pathogens Rotavirus, Adenovirus, Norovirus, Campylobacter spp., Salmonella spp., Giardia spp., and Cryptosporidium spp.. Non-potable uses included indoor use (for toilet flushing and clothes washing) with accidental ingestion of treated non-potable water (or cross connection with potable water), and unrestricted irrigation for outdoor use. Various exposure scenarios captured the uncertainty from key inputs, i.e., the pathogen concentration in source water; the volume of water ingested; and for the indoor use, the frequency of and the fraction of the population exposed to accidental ingestion. Both potable and non-potable uses required pathogen treatment for the selected waters and the LRT was generally greater for potable use than nonpotable indoor use and unrestricted irrigation. The difference in treatment requirements among source waters was driven by th

  5. Risk-based enteric pathogen reduction targets for non-potable ...

    EPA Pesticide Factsheets

    This paper presents risk-based enteric pathogen log reduction targets for non-potable and potable uses of a variety of alternative source waters (i.e., locally-collected greywater, roof runoff, and stormwater). A probabilistic Quantitative Microbial Risk Assessment (QMRA) was used to derive the pathogen log10 reduction targets (LRTs) that corresponded with an infection risk of either 10−4 per person per year (ppy) or 10−2 ppy. The QMRA accounted for variation in pathogen concentration and sporadic pathogen occurrence (when data were available) in source waters for reference pathogens in the genera Rotavirus, Mastadenovirus (human adenoviruses), Norovirus, Campylobacter, Salmonella, Giardia and Cryptosporidium. Non-potable uses included indoor use (for toilet flushing and clothes washing) with occasional accidental ingestion of treated non-potable water (or cross-connection with potable water), and unrestricted irrigation for outdoor use. Various exposure scenarios captured the uncertainty from key inputs, i.e., the pathogen concentration in source water; the volume of water ingested; and for the indoor use, the frequency of and the fraction of the population exposed to accidental ingestion. Both potable and non-potable uses required pathogen treatment for the selected waters and the LRT was generally greater for potable use than non-potable indoor use and unrestricted irrigation. The difference in treatment requirements among source waters was driven by the

  6. Research on Extension of Sparql Ontology Query Language Considering the Computation of Indoor Spatial Relations

    NASA Astrophysics Data System (ADS)

    Li, C.; Zhu, X.; Guo, W.; Liu, Y.; Huang, H.

    2015-05-01

    A method suitable for indoor complex semantic query considering the computation of indoor spatial relations is provided According to the characteristics of indoor space. This paper designs ontology model describing the space related information of humans, events and Indoor space objects (e.g. Storey and Room) as well as their relations to meet the indoor semantic query. The ontology concepts are used in IndoorSPARQL query language which extends SPARQL syntax for representing and querying indoor space. And four types specific primitives for indoor query, "Adjacent", "Opposite", "Vertical" and "Contain", are defined as query functions in IndoorSPARQL used to support quantitative spatial computations. Also a method is proposed to analysis the query language. Finally this paper adopts this method to realize indoor semantic query on the study area through constructing the ontology model for the study building. The experimental results show that the method proposed in this paper can effectively support complex indoor space semantic query.

  7. Theory-Driven Longitudinal Study Exploring Indoor Tanning Initiation in Teens Using a Person-Centered Approach

    PubMed Central

    Hillhouse, Joel; Turrisi, Rob; Cleveland, Michael J.; Scaglione, Nichole M.; Baker, Katie; Florence, L. Carter

    2015-01-01

    Background Younger indoor tanning initiation leads to greater melanoma risk due to more frequent and persistent behavior. Despite this, there are no published studies exploring the predictors of indoor tanning initiation in teen populations. Purpose This longitudinal study uses latent profile analysis to examine indoor tanning initiation in indoor tanning risk subgroups from a national sample of female adolescents. Methods Latent profile analysis used indoor tanning beliefs and perceptions to identify indoor tanning initiation risk subgroups. The teens in each subgroup were reassessed on indoor tanning initiation after a year. Results Three subgroups were identified: a low-risk, Anti-Tanning subgroup (18.6%) characterized by low scores on positive indoor tanning belief scales and high scores on beliefs about indoor tanning dangers; a moderate-risk Aware Social Tanner subgroup (47.2%) characterized by high scores on positive indoor tanning belief scales but also high scores on beliefs about indoor tanning dangers; and a high-risk Risky Relaxation Tanner subgroup (34.2%) characterized by high scores on positive indoor tanning belief scales and low scores on beliefs about indoor tanning dangers. Teens in the Aware Social Tanner and Risky Relaxation Tanner subgroups were significantly more likely to initiate indoor tanning in the following year. Conclusions These findings highlight the need to identify teens at risk for indoor tanning initiation and develop tailored interventions that will move them to the lowest risk subgroup. Subgroup correlates suggest parent and peer-based interventions may be successful. PMID:26370893

  8. Theory-Driven Longitudinal Study Exploring Indoor Tanning Initiation in Teens Using a Person-Centered Approach.

    PubMed

    Hillhouse, Joel; Turrisi, Rob; Cleveland, Michael J; Scaglione, Nichole M; Baker, Katie; Florence, L Carter

    2016-02-01

    Younger indoor tanning initiation leads to greater melanoma risk due to more frequent and persistent behavior. Despite this, there are no published studies exploring the predictors of indoor tanning initiation in teen populations. This longitudinal study uses latent profile analysis to examine indoor tanning initiation in indoor tanning risk subgroups from a national sample of female adolescents. Latent profile analysis used indoor tanning beliefs and perceptions to identify indoor tanning initiation risk subgroups. The teens in each subgroup were reassessed on indoor tanning initiation after a year. Three subgroups were identified: a low risk, anti-tanning subgroup (18.6 %) characterized by low scores on positive indoor tanning belief scales and high scores on beliefs about indoor tanning dangers; a moderate risk aware social tanner subgroup (47.2 %) characterized by high scores on positive indoor tanning belief scales but also high scores on beliefs about indoor tanning dangers; and a high risk risky relaxation tanner subgroup (34.2 %) characterized by high scores on positive indoor tanning belief scales and low scores on beliefs about indoor tanning dangers. Teens in the aware social tanner and risky relaxation tanner subgroups were significantly more likely to initiate indoor tanning in the following year. These findings highlight the need to identify teens at risk for indoor tanning initiation and develop tailored interventions that will move them to the lowest risk subgroup. Subgroup correlates suggest parent and peer-based interventions may be successful.

  9. Hygrothermal Analysis of Indoor Environment of Residential Prefabricated Buildings

    NASA Astrophysics Data System (ADS)

    Kraus, Michal

    2017-10-01

    Recent studies show that the relative humidity and the indoor air temperature constitute an important determinant of the quality of indoor air. Hygrothermal microclimate has a significant impact on occupant’s health and their comfort. The study presents the results of experimental measurement of indoor air temperature and relative humidity in selected apartment in prefabricated panel house situated in Ostrava, Czechia. The contribution describes and analysis the relation between indoor air temperature [°C] and relative humidity [%] in this apartment. The experimental object is selected with respect to the housing stock in the Czech Republic. A third of the housing stock in the Czech Republic is composed of prefabricated panel houses. Regeneration and revitalization of these buildings were in the focus of interest during recent years. Building modifications, such as thermal insulation of building envelope or window replacement, lead to a significantly higher level of airtightness of these objects. Humidity and indoor air temperature are measured in 10-minute cycles for two periods. The values of temperature and humidity are measured for the non-heating and the heating season. The length of each experimental period is 30 days. The mean value of indoor air temperature is 22.21 °C and average relative humidity is 45.87% in the non-heating period. The values of 22.62 °C and 35.20% represent average values for the heating period. A slight increase of the average temperature of the indoor environment (+1.85%) is observed. The decrease of the relative humidity is evident at first glance. The relative humidity of the internal environment is approximately 10% lower in the heating period. Long-term decline of relative humidity below 30% brings many problems. It is necessary to take measures to increase of relative humidity in residential prefabricated building. The aquarium appears to be ineffective. The solution may be forced artificial ventilation or humidifiers.

  10. Integration of GIS and Bim for Indoor Geovisual Analytics

    NASA Astrophysics Data System (ADS)

    Wu, B.; Zhang, S.

    2016-06-01

    This paper presents an endeavour of integration of GIS (Geographical Information System) and BIM (Building Information Modelling) for indoor geovisual analytics. The merits of two types of technologies, GIS and BIM are firstly analysed in the context of indoor environment. GIS has well-developed capabilities of spatial analysis such as network analysis, while BIM has the advantages for indoor 3D modelling and dynamic simulation. This paper firstly investigates the important aspects for integrating GIS and BIM. Different data standards and formats such as the IFC (Industry Foundation Classes) and GML (Geography Markup Language) are discussed. Their merits and limitations in data transformation between GIS and BIM are analysed in terms of semantic and geometric information. An optimized approach for data exchange between GIS and BIM datasets is then proposed. After that, a strategy of using BIM for 3D indoor modelling, GIS for spatial analysis, and BIM again for visualization and dynamic simulation of the analysis results is presented. Based on the developments, this paper selects a typical problem, optimized indoor emergency evacuation, to demonstrate the integration of GIS and BIM for indoor geovisual analytics. The block Z of the Hong Kong Polytechnic University is selected as a test site. Detailed indoor and outdoor 3D models of the block Z are created using a BIM software Revit. The 3D models are transferred to a GIS software ArcGIS to carry out spatial analysis. Optimized evacuation plans considering dynamic constraints are generated based on network analysis in ArcGIS assuming there is a fire accident inside the building. The analysis results are then transferred back to BIM software for visualization and dynamic simulation. The developed methods and results are of significance to facilitate future development of GIS and BIM integrated solutions in various applications.

  11. ASSOCIATIONS BETWEEN SEASONAL SLEEP CHANGE AND INDOOR TANNING1,2

    PubMed Central

    CULNAN, ELIZABETH; KLOSS, JACQUELINE D.; DARLOW, SUSAN; HECKMAN, CAROLYN J.

    2015-01-01

    Summary Identification of risk factors for indoor tanning may ultimately aid the development of better indoor tanning prevention strategies, which is pertinent given the association between indoor tanning and skin cancer. This study aimed to examine the relationship between seasonal sleep change and indoor tanning. Women tanners (N= 139) completed self-report measures including items relating to seasonal sleep changes, seasonal affective disorder (SAD), reasons for tanning, tanning during the winter months, and the Tanning Pathology Scale (TAPS), which measures problematic tanning motives and symptoms of tanning dependence. It was hypothesized that seasonal sleep change and SAD would be associated with greater indoor tanning during the winter, more tanning to improve mood and to relax, and higher scores on the TAPS. Findings indicated that more seasonal sleep change was associated with tanning to improve mood and higher scores on the TAPS. Similarly, the presence of SAD was related to tanning to improve mood, tanning to relax, and more problematic tanning. PMID:25730744

  12. Indoor environmental quality in French dwellings and building characteristics

    NASA Astrophysics Data System (ADS)

    Langer, Sarka; Ramalho, Olivier; Derbez, Mickaël; Ribéron, Jacques; Kirchner, Severine; Mandin, Corinne

    2016-03-01

    A national survey on indoor environmental quality covering 567 residences in mainland France was performed during 2003-2005. The measured parameters were temperature, relative humidity, CO2, and the indoor air pollutants: fourteen individual volatile organic compounds (VOC), four aldehydes and particulate matter PM10 and PM2.5. The measured indoor concentrations were analyzed for correlations with the building characteristics: type of dwelling, period of construction, dwelling location, type of ventilation system, building material, attached garage and retrofitting. The median night time air exchange rate (AER) for all dwellings was 0.44 h-1. The night time AER was higher in apartments (median = 0.49 h-1) than in single-family houses (median = 0.41 h-1). Concentration of formaldehyde was approximately 30% higher in dwellings built after 1990 compared with older ones; it was higher in dwellings with mechanical ventilation and in concrete buildings. The VOC concentrations depended on the building characteristics to various extents. The sampling season influenced the majority of the indoor climate parameters and the concentrations of the air pollutants to a higher degree than the building characteristics. Multivariate linear regression models revealed that the indoor-outdoor difference in specific humidity, a proxy for number of occupants and their indoor activities, remained a significant predictor for most gaseous and particulate air pollutants. The other strong predictors were outdoor concentration, smoking, attached garage and AER (in descending order).

  13. Managing Formaldehyde indoor pollution in anatomy pathology departments.

    PubMed

    d'Ettorre, Gabriele; Criscuolo, Mario; Mazzotta, Mauro

    2017-01-01

    Nearly eleven years have passed since the International Agency for Research on Cancer classified Formaldehyde (FA) as a known human carcinogen (group 1), yet the safety of anatomy pathology workers who are currently exposed to FA is still a matter of concern. The purpose of this study was to evaluate the literature to discover which topics have been focused on and what the latest developments are in managing FA indoor pollution in anatomy pathology departments. which topics have been focused on and what the latest developments in managing FA indoor pollution in anatomy pathology departments. For the purpose of this review, we searched for publications in PubMed and Web of Science using selected keywords. The articles were reviewed and categorized into one or more of the following three categories based on subject matter: exposure levels exposure controls and alternatives. Our search resulted in a total of 31 publications that matched our inclusion criteria. The topics discussed, in order of frequency (from highest to lowest), were: "exposure controls", "exposure levels" and "alternatives". The most frequently suggested intervention was to improve local exhaust ventilation systems to minimize FA levels in gross anatomy laboratories. We found a lack of evidence-based improvement interventions that aimed to control exposure to FA. According to this finding, and pending a valid chemical substitute for FA, we suggest the need for more in-depth studies targeting measures to minimize exposures to FA in pathology departments.

  14. Reference Guide. Indoor Air Quality Tools for Schools

    ERIC Educational Resources Information Center

    US Environmental Protection Agency, 2009

    2009-01-01

    Understanding the importance of good indoor air quality (IAQ) in schools is the backbone of developing an effective Indoor Air Quality (IAQ) program. Poor IAQ can lead to a large variety of health problems and potentially affect comfort, concentration, and staff/student performance. In recognition of tight school budgets, this guidance is designed…

  15. Exposure to airborne engineered nanoparticles in the indoor environment

    NASA Astrophysics Data System (ADS)

    Vance, Marina E.; Marr, Linsey C.

    2015-04-01

    This literature review assesses the current state of knowledge about inhalation exposure to airborne, engineered nanoparticles in the indoor environment. We present principal exposure scenarios in indoor environments, complemented by analysis of the published literature and of an inventory of nanotechnology-enhanced consumer products. Of all products listed in the inventory, 10.8% (194 products) present the potential for aerosolization of nanomaterials and subsequent inhalation exposure during use or misuse. Among those, silver-containing products are the most prevalent (68 products). Roughly 50% of products would release wet aerosols and 50% would potentially release dry aerosols. Approximately 14% are cleaning products that can be broadly used in public indoor environments, where building occupants may be exposed. While a variety of nanomaterial compositions have been investigated in the limited number of published release and exposure studies, we identified a need for studies investigating nanofibers (beyond carbon nanotubes), nanofilms, nanoplatelets, and other emerging nanomaterials such as ceria and their nanocomposites. Finally, we provide recommendations for future research to advance the understanding of exposure to airborne nanomaterials indoors, such as studies into indoor chemistry of nanomaterials, better nanomaterial reporting and labeling in consumer products, and safer design of nanomaterial-containing consumer products.

  16. Ultra Wideband Indoor Positioning Technologies: Analysis and Recent Advances.

    PubMed

    Alarifi, Abdulrahman; Al-Salman, AbdulMalik; Alsaleh, Mansour; Alnafessah, Ahmad; Al-Hadhrami, Suheer; Al-Ammar, Mai A; Al-Khalifa, Hend S

    2016-05-16

    In recent years, indoor positioning has emerged as a critical function in many end-user applications; including military, civilian, disaster relief and peacekeeping missions. In comparison with outdoor environments, sensing location information in indoor environments requires a higher precision and is a more challenging task in part because various objects reflect and disperse signals. Ultra WideBand (UWB) is an emerging technology in the field of indoor positioning that has shown better performance compared to others. In order to set the stage for this work, we provide a survey of the state-of-the-art technologies in indoor positioning, followed by a detailed comparative analysis of UWB positioning technologies. We also provide an analysis of strengths, weaknesses, opportunities, and threats (SWOT) to analyze the present state of UWB positioning technologies. While SWOT is not a quantitative approach, it helps in assessing the real status and in revealing the potential of UWB positioning to effectively address the indoor positioning problem. Unlike previous studies, this paper presents new taxonomies, reviews some major recent advances, and argues for further exploration by the research community of this challenging problem space.

  17. Delay Tracking of Spread-Spectrum Signals for Indoor Optical Ranging

    PubMed Central

    Salido-Monzú, David; Martín-Gorostiza, Ernesto; Lázaro-Galilea, José Luis; Martos-Naya, Eduardo; Wieser, Andreas

    2014-01-01

    Delay tracking of spread-spectrum signals is widely used for ranging in radio frequency based navigation. Its use in non-coherent optical ranging, however, has not been extensively studied since optical channels are less subject to narrowband interference situations where these techniques become more useful. In this work, an early-late delay-locked loop adapted to indoor optical ranging is presented and analyzed. The specific constraints of free-space infrared channels in this context substantially differ from those typically considered in radio frequency applications. The tracking stage is part of an infrared differential range measuring system with application to mobile target indoor localization. Spread-spectrum signals are used in this context to provide accurate ranging while reducing the effect of multipath interferences. The performance of the stage regarding noise and dynamic errors is analyzed and validated, providing expressions that allow an adequate selection of the design parameters depending on the expected input signal characteristics. The behavior of the stage in a general multipath scenario is also addressed to estimate the multipath error bounds. The results, evaluated under realistic conditions corresponding to an 870 nm link with 25 MHz chip-rate, built with low-cost up-to-date devices, show that an overall error below 6% of a chip time can be achieved. PMID:25490585

  18. Annual trauma load of the world's largest indoor skiing center.

    PubMed

    Van Laarhoven, S N; Latten, G; de Loos, E; van Hemert, W; Vles, G F

    2017-04-01

    There is limited data on the trauma load caused by indoor skiing centers. Therefore, all patients treated at the accident and emergency department of our level I trauma center who sustained injuries at the world's largest indoor skiing center were analyzed during a 3-year period. Business intelligence was used to identify all patients who sustained injury at SnowWorld, Landgraaf, The Netherlands, and were seen at the accident and emergency department of the Zuyderland Medical Center from January 1, 2012 till December 31, 2014. Data were collected on patient characteristics, trauma mechanism, transportation, admission, diagnostics, injury and its severity, and treatment. Of the 732 patients seen, 305 had a fracture and 80 a dislocation. Most patients were male snowboarders and most injuries were sustained during winter. More than 2000 X-rays and 100 CT scans were required. Seventy-two patients were admitted and immediate surgery was performed in 21 patients. Ten patients had Injury Severity Scores of 10 or higher. Snowboarders differed significantly from skiers on several parameters, e.g., 1 in 4 snowboarders seen had sustained a distal radius fracture compared to 1 in 100 skiers. Acquiring more insight into the characteristics of this specific patient population could benefit clinical care and help clinicians identify and target preventive strategies. IV.

  19. Impact of operating wood-burning fireplace ovens on indoor air quality.

    PubMed

    Salthammer, Tunga; Schripp, Tobias; Wientzek, Sebastian; Wensing, Michael

    2014-05-01

    The use of combustion heat sources like wood-burning fireplaces has regained popularity in the past years due to increasing energy costs. While the outdoor emissions from wood ovens are strictly regulated in Germany, the indoor release of combustion products is rarely considered. Seven wood burning fireplaces were tested in private homes between November 2012 and March 2013. The indoor air quality was monitored before, during and after operation. The following parameters were measured: ultra-fine particles (5.6-560 nm), fine particles (0.3-20 μm), PM2.5, NOx, CO, CO2, formaldehyde, acetaldehyde, volatile organic compounds (VOCs) and benzo[a]pyrene (BaP). Most ovens were significant sources of particulate matter. In some cases, an increase of benzene and BaP concentrations was observed in the indoor air. The results illustrate that wood-burning fireplaces are potential sources of indoor air contaminants, especially ultra-fine particles. Under the aspect of lowering indoor air exchange rates and increasing the use of fuels with a net zero-carbon footprint, indoor combustion sources are an important topic for the future. With regards to consumer safety, product development and inspection should consider indoor air quality in addition to the present fire protection requirements. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Assessment of the Indoor Odour Impact in a Naturally Ventilated Room

    PubMed Central

    Eusebio, Lidia; Derudi, Marco; Capelli, Laura; Nano, Giuseppe; Sironi, Selena

    2017-01-01

    Indoor air quality influences people’s lives, potentially affecting their health and comfort. Nowadays, ventilation is the only technique commonly used for regulating indoor air quality. CO2 is the reference species considered in order to calculate the air exchange rates of indoor environments. Indeed, regarding air quality, the presence of pleasant or unpleasant odours can strongly influence the environmental comfort. In this paper, a case study of indoor air quality monitoring is reported. The indoor field tests were conducted measuring both CO2 concentration, using a photoacoustic multi-gas analyzer, and odour trends, using an electronic nose, in order to analyze and compare the information acquired. The indoor air monitoring campaign was run for a period of 20 working days into a university room. The work was focused on the determination of both CO2 and odour emission factors (OEF) emitted by the human activity and on the evaluation of the odour impact in a naturally ventilated room. The results highlighted that an air monitoring and recycling system based only on CO2 concentration and temperature measurements might be insufficient to ensure a good indoor air quality, whereas its performances could be improved by integrating the existing systems with an electronic nose for odour detection. PMID:28379190

  1. Interior shadings for office indoor visual comfort in humid climate region

    NASA Astrophysics Data System (ADS)

    Dinapradipta, Asri; Sudarma, Erwin; Defiana, Ima; Erwindi, Collinthia

    2018-03-01

    As part of the fenestration system, the interior shadings have also a role to control the indoor environment to maintain indoor visual comfort. As the occupants have personal access to control these, their control behavior then, might enhance or even worsen indoor comfort performance. The controlling behavior might not only influence indoor comfort performance but can also indicate the success or failure of interior shading as a control device element. This paper is intended to report control behavior patterns, as represented by the variety of the slats’ openings of two types of interior shading i.e. Venetian and Vertical blinds and to analyze these on the concurrent impacts to indoor office building’s indoor illuminance and luminance distribution. The purpose of this research is to figure out the shading control patterns as well as to examine the effectiveness of these two types of interior shadings to control indoor visual environment. This study is a quantitative research using experimentation on the slats’ opening of two types of shadings at two identical office rooms. The research results suggested that both types of blinds seem unsuitable for gaining proper illumination values at work planes in humid tropics area. However, these shadings demonstrate good performance for luminance distribution except for that of the closed Venetian blinds.

  2. Indoor Air Quality in Schools: Understanding the Problem and Finding the Solution.

    ERIC Educational Resources Information Center

    Bacci, Geoff

    2002-01-01

    Describes issues and solutions involving indoor air quality in school. Includes indoor air quality action plans, the role of the environmental consultant, and resources available to help school districts develop an indoor air quality action plan. (PKP)

  3. In search of a common European approach to a healthy indoor environment.

    PubMed

    Adan, Olaf C G; Ng-A-Tham, Julie; Hanke, Wojtek; Sigsgaard, Torben; van den Hazel, Peter; Wu, Felicia

    2007-06-01

    Increasingly, policymakers in Europe and around the world are realizing the importance of healthy indoor environments for public health. Certain member states of the European Union (EU) have already achieved successes in improving indoor environmental quality, such as controlling certain contaminants (e.g., environmental tobacco smoke) or developing nationwide policies that address indoor air generally. However, a common European approach to achieving healthy indoor environments is desirable for several reasons including providing a broader recognition of the problem of unhealthy indoor air, setting a policy example for all 27 EU member states, and achieving greater public health equity across the different European nations. In this article we address the question "Why is it so difficult in the EU to develop a coherent approach on indoor environment?" We identify and describe four main barriers: a) the subsidiarity principle in EU policymaking, introducing decentralization of decision making to the member states; b) fragmentation of the topic of the indoor environment; c) the differences in climate and governance among different member states that make a common policy difficult; and d) economic issues. We discuss potential lessons and recommendations from EU and U.S. successes in achieving healthier indoor environments through various policy mechanisms.

  4. An updated review of case-control studies of lung cancer and indoor radon-Is indoor radon the risk factor for lung cancer?

    PubMed

    Sheen, Seungsoo; Lee, Keu Sung; Chung, Wou Young; Nam, Saeil; Kang, Dae Ryong

    2016-01-01

    Lung cancer is a leading cause of cancer-related death in the world. Smoking is definitely the most important risk factor for lung cancer. Radon ((222)Rn) is a natural gas produced from radium ((226)Ra) in the decay series of uranium ((238)U). Radon exposure is the second most common cause of lung cancer and the first risk factor for lung cancer in never-smokers. Case-control studies have provided epidemiological evidence of the causative relationship between indoor radon exposure and lung cancer. Twenty-four case-control study papers were found by our search strategy from the PubMed database. Among them, seven studies showed that indoor radon has a statistically significant association with lung cancer. The studies performed in radon-prone areas showed a more positive association between radon and lung cancer. Reviewed papers had inconsistent results on the dose-response relationship between indoor radon and lung cancer risk. Further refined case-control studies will be required to evaluate the relationship between radon and lung cancer. Sufficient study sample size, proper interview methods, valid and precise indoor radon measurement, wide range of indoor radon, and appropriate control of confounders such as smoking status should be considered in further case-control studies.

  5. Rethinking Indoor Localization Solutions Towards the Future of Mobile Location-Based Services

    NASA Astrophysics Data System (ADS)

    Guney, C.

    2017-11-01

    Satellite navigation systems with GNSS-enabled devices, such as smartphones, car navigation systems, have changed the way users travel in outdoor environment. GNSS is generally not well suited for indoor location and navigation because of two reasons: First, GNSS does not provide a high level of accuracy although indoor applications need higher accuracies. Secondly, poor coverage of satellite signals for indoor environments decreases its accuracy. So rather than using GNSS satellites within closed environments, existing indoor navigation solutions rely heavily on installed sensor networks. There is a high demand for accurate positioning in wireless networks in GNSS-denied environments. However, current wireless indoor positioning systems cannot satisfy the challenging needs of indoor location-aware applications. Nevertheless, access to a user's location indoors is increasingly important in the development of context-aware applications that increases business efficiency. In this study, how can the current wireless location sensing systems be tailored and integrated for specific applications, like smart cities/grids/buildings/cars and IoT applications, in GNSS-deprived areas.

  6. Indoor Tanning (For Teens)

    MedlinePlus

    ... young patients for skin cancer. Indoor Tanning vs. Sunlight The sun's rays contain two types of ultraviolet radiation that ... as much — if not more — damage as the sun. Plus, the concentration of UVA rays from a ...

  7. A CROSS-PROVINCE ANALYSIS OF URBAN AND RURAL INDOOR PM2.5 EXPOSURE IN CHINA USING TIME USE SURVEY

    NASA Astrophysics Data System (ADS)

    Shimada, Yoko; Guo, Minna; Kurata, Gakuji; Matsuoka, Yuzuru

    In developing countries in Asia and other parts of the world, most energy sources used in the home are solid fuels such as coal and biomass (firewood, crop residue and animal dung). Particulate matter 2.5, consisting of particles with an aerodynamic diameter of 2.5 um or less, produced through combustion of these fuels inside the residence for cooking and heating has an adverse impact on people's health. We estimated PM2.5 exposure concentration in indoor microenvironment for each cohort of urban and rural area in ten provinces of China, using statistical data on time use survey and domestic energy consumption. The study found that, in each province, the exposure concentration in rural area was higher than in urban area, unemployed women between the ages of 60 and 64 had the highest estimate for exposure concentration at 3027 μg/m3. The study also found that the exposure concentration for individual cohorts in each province was greatly affected by people's use of time indoors, fuel consumption such as coal or biomass and floor space.

  8. Investigating a method for reducing residual switch costs in cued task switching.

    PubMed

    Schneider, Darryl W

    2016-07-01

    Residual switch costs in cued task switching are performance decrements that occur despite a long cue-target interval (CTI) to prepare for a task switch. Verbruggen, Liefooghe, Vandierendonck, and Demanet (Journal of Experimental Psychology: Learning, Memory, and Cognition, 33; 342-356, 2007) showed that briefly presenting the cue during the CTI and leaving it absent after target onset yielded smaller residual switch costs than those obtained when the cue was available for the full CTI and remained present after target onset. The potential effects of cue availability during the CTI (full or partial) and cue status after target onset (present or absent) on residual switch costs were investigated in the present study. In Experiments 1 and 2, cue status was manipulated while holding cue availability constant. In Experiments 3 and 4, cue status and cue availability were manipulated factorially. Residual switch costs were obtained, but they were not modulated consistently by cue status or cue availability across experiments. In Experiment 5, a direct replication of one of Verbruggen and colleagues' experiments yielded divergent results. Implications for understanding task switching are discussed.

  9. How to Create Healthy Indoor Environments in Schools

    ERIC Educational Resources Information Center

    Rhodes, Diane; Di Nella, Frank

    2012-01-01

    A green and healthy indoor environment should be a fundamental concern in the place where kids learn and grow. Good indoor air quality (IAQ) has been shown to have positive effects on student and staff productivity, performance, comfort and attendance. Conversely, poor IAQ in classrooms--caused by mold and moisture issues, problems with HVAC…

  10. Indoor-Outdoor Air Pollution Relationship: A Literature Review.

    ERIC Educational Resources Information Center

    Benson, Ferris B.; And Others

    While extensive measurements have been and are being made of outdoor pollution, relatively few data have been gathered on indoor pollution. The data that are available are compiled and analyzed in the report. Based on a review of the literature, it was possible to infer relationships between indoor and outdoor pollution and to identify factors…

  11. Lantos-Hyde United States Government Malaria Strategy, 2009-2014

    DTIC Science & Technology

    2010-04-25

    Long lasting insecticide -treated nets (LLINs); • Indoor residual spraying (IRS) with insecticides ; • Intermittent preventive treatment of...measures: insecticide -treated mosquito nets (ITNs); indoor residual spraying (IRS) of insecticides ; artemisinin-based combination therapy (ACTs); and...is national policy. Indoor residual spraying : Between 2005 and 2009, PMI supported the introduction or

  12. A smart indoor air quality sensor network

    NASA Astrophysics Data System (ADS)

    Wen, Jin

    2006-03-01

    The indoor air quality (IAQ) has an important impact on public health. Currently, the indoor air pollution, caused by gas, particle, and bio-aerosol pollutants, is considered as the top five environmental risks to public health and has an estimated cost of $2 billion/year due to medical cost and lost productivity. Furthermore, current buildings are especially vulnerable for chemical and biological warfare (CBW) agent contamination because the central air conditioning and ventilation system serve as a nature carrier to spread the released agent from one location to the whole indoor environment within a short time period. To assure the IAQ and safety for either new or existing buildings, real time comprehensive IAQ and CBW measurements are needed. With the development of new sensing technologies, economic and reliable comprehensive IAQ and CBW sensors become promising. However, few studies exist that examine the design and evaluation issues related to IAQ and CBW sensor network. In this paper, relevant research areas including IAQ and CBW sensor development, demand control ventilation, indoor CBW sensor system design, and sensor system design for other areas such as water system protection, fault detection and diagnosis, are reviewed and summarized. Potential research opportunities for IAQ and CBW sensor system design and evaluation are discussed.

  13. Indoor-Outdoor Detection Using a Smart Phone Sensor.

    PubMed

    Wang, Weiping; Chang, Qiang; Li, Qun; Shi, Zesen; Chen, Wei

    2016-09-22

    In the era of mobile internet, Location Based Services (LBS) have developed dramatically. Seamless Indoor and Outdoor Navigation and Localization (SNAL) has attracted a lot of attention. No single positioning technology was capable of meeting the various positioning requirements in different environments. Selecting different positioning techniques for different environments is an alternative method. Detecting the users' current environment is crucial for this technique. In this paper, we proposed to detect the indoor/outdoor environment automatically without high energy consumption. The basic idea was simple: we applied a machine learning algorithm to classify the neighboring Global System for Mobile (GSM) communication cellular base station's signal strength in different environments, and identified the users' current context by signal pattern recognition. We tested the algorithm in four different environments. The results showed that the proposed algorithm was capable of identifying open outdoors, semi-outdoors, light indoors and deep indoors environments with 100% accuracy using the signal strength of four nearby GSM stations. The required hardware and signal are widely available in our daily lives, implying its high compatibility and availability.

  14. Wi-Fi/MARG Integration for Indoor Pedestrian Localization.

    PubMed

    Tian, Zengshan; Jin, Yue; Zhou, Mu; Wu, Zipeng; Li, Ze

    2016-12-10

    With the wide deployment of Wi-Fi networks, Wi-Fi based indoor localization systems that are deployed without any special hardware have caught significant attention and have become a currently practical technology. At the same time, the Magnetic, Angular Rate, and Gravity (MARG) sensors installed in commercial mobile devices can achieve highly-accurate localization in short time. Based on this, we design a novel indoor localization system by using built-in MARG sensors and a Wi-Fi module. The innovative contributions of this paper include the enhanced Pedestrian Dead Reckoning (PDR) and Wi-Fi localization approaches, and an Extended Kalman Particle Filter (EKPF) based fusion algorithm. A new Wi-Fi/MARG indoor localization system, including an Android based mobile client, a Web page for remote control, and a location server, is developed for real-time indoor pedestrian localization. The extensive experimental results show that the proposed system is featured with better localization performance, with the average error 0.85 m, than the one achieved by using the Wi-Fi module or MARG sensors solely.

  15. Wi-Fi/MARG Integration for Indoor Pedestrian Localization

    PubMed Central

    Tian, Zengshan; Jin, Yue; Zhou, Mu; Wu, Zipeng; Li, Ze

    2016-01-01

    With the wide deployment of Wi-Fi networks, Wi-Fi based indoor localization systems that are deployed without any special hardware have caught significant attention and have become a currently practical technology. At the same time, the Magnetic, Angular Rate, and Gravity (MARG) sensors installed in commercial mobile devices can achieve highly-accurate localization in short time. Based on this, we design a novel indoor localization system by using built-in MARG sensors and a Wi-Fi module. The innovative contributions of this paper include the enhanced Pedestrian Dead Reckoning (PDR) and Wi-Fi localization approaches, and an Extended Kalman Particle Filter (EKPF) based fusion algorithm. A new Wi-Fi/MARG indoor localization system, including an Android based mobile client, a Web page for remote control, and a location server, is developed for real-time indoor pedestrian localization. The extensive experimental results show that the proposed system is featured with better localization performance, with the average error 0.85 m, than the one achieved by using the Wi-Fi module or MARG sensors solely. PMID:27973412

  16. Indoor External Radiation Risk in Densely Populated Regions of Southern Nigeria

    NASA Astrophysics Data System (ADS)

    Ife-Adediran, Oluwatobi O.; Uwadiae, Iyobosa B.

    2018-02-01

    It is known that certain types of building materials contain significant concentrations of natural radionuclides; consequently, exposure to indoor background radiation is from the combined radioactivity from the soil as well as building materials; indoor exposures therefore have higher radiation hazard potentials than outdoor exposures in this regard and hence, need to be monitored. In this paper, an evaluation of background ionizing radiation from different buildings in Lagos and Ibadan, Southwestern Nigeria was carried out to determine the exposure rate of the general public to indoor ionizing radiation. 630 in situ measurements from the different buildings were taken using a Geiger Muller counter (model GQ-320 Plus). The indoor dose rates (i.e., 50-120 nGy/h) were within the world average values while the Annual Effective Dose for most of the buildings were above the world average AED for indoor gamma exposure from building materials. The mean AED for Lagos and Ibadan due to indoor exposures were 0.37 and 0.39 mSv/y with Excess Lifetime Cancer Risk of 0.99E-3 and 1.05E-3, respectively.

  17. Feasibility study on mental healthcare using indoor plants for office workers

    NASA Astrophysics Data System (ADS)

    Kubota, Tsuyoshi; Matsumoto, Hiroshi; Genjo, Kaori; Nakano, Takaoki

    2017-10-01

    In recent years, it has become a problem that office workers' stresses affect their intellectual productivity. As one of strategies mitigating the stress while working, many studies on the effect of indoor plants introduced into the office have been conducted. The psychological and physiological effects of indoor plants have been expected to mitigate the office workers' stresses. Also, the effects of green amenities such as improvement of productivity, control of the indoor thermal environment, relaxation and recovery of visual fatigue, and improvement of air quality have been expected. In this study, a field investigation on the green amenity effects of indoor plants on office workers' psychological and physiological responses in an actual office was conducted and discussed. This paper describes the measurement results of the physical environment and workers' psychological and physiological responses under the condition with shelves installed with indoor plants in an office room. It was suggested that indoor plants such as mint, basil and begonia, and a combination of red and green plants were effective for mitigating worker's stresses.

  18. Indoor External Radiation Risk in Densely Populated Regions of Southern Nigeria

    NASA Astrophysics Data System (ADS)

    Ife-Adediran, Oluwatobi O.; Uwadiae, Iyobosa B.

    2018-05-01

    It is known that certain types of building materials contain significant concentrations of natural radionuclides; consequently, exposure to indoor background radiation is from the combined radioactivity from the soil as well as building materials; indoor exposures therefore have higher radiation hazard potentials than outdoor exposures in this regard and hence, need to be monitored. In this paper, an evaluation of background ionizing radiation from different buildings in Lagos and Ibadan, Southwestern Nigeria was carried out to determine the exposure rate of the general public to indoor ionizing radiation. 630 in situ measurements from the different buildings were taken using a Geiger Muller counter (model GQ-320 Plus). The indoor dose rates (i.e., 50-120 nGy/h) were within the world average values while the Annual Effective Dose for most of the buildings were above the world average AED for indoor gamma exposure from building materials. The mean AED for Lagos and Ibadan due to indoor exposures were 0.37 and 0.39 mSv/y with Excess Lifetime Cancer Risk of 0.99E-3 and 1.05E-3, respectively.

  19. The Development and Validation of the Mood-based Indoor Tanning Scale.

    PubMed

    Carcioppolo, Nick; Chen, Yixin; John, Kevin K; Gonzalez, Andrea Martinez; King, Andy J; Morgan, Susan E; Hu, Shasa

    2017-01-01

    Research indicates that mood-based motivations may be an important predictor of indoor tanning bed use and may be related to indoor tanning dependence. Problematically, little research has been conducted to develop a psychometric measure of mood-based tanning motivations. The current study seeks to develop and validate the moodbased indoor tanning scale (MITS). Two studies were conducted to identify and verify the MITS factor structure as well as assess construct validity. Study 1 was conducted at 5 geographically diverse universities in the United States. Study 2 was conducted by using a national online sample in the United States. Results from study 1 specified the factor structure of the MITS. Results from study 2 suggest that a one-point increase in the MITS measure corresponds with using indoor tanning beds 11 more times in the past year. These findings demonstrate that moodbased tanning motivations are a strong predictor of indoor tanning intentions and behavior. Further, they suggest that health behavior researchers and healthcare practitioners can use the MITS to assess the extent to which mood-based motivations impact indoor tanning bed use.

  20. Cryostat including heater to heat a target

    DOEpatents

    Pehl, R.H.; Madden, N.W.; Malone, D.F.

    1990-09-11

    A cryostat is provided which comprises a vacuum vessel; a target disposed within the vacuum vessel; a heat sink disposed within the vacuum vessel for absorbing heat from the detector; a cooling mechanism for cooling the heat sink; a cryoabsorption mechanism for cryoabsorbing residual gas within the vacuum vessel; and a heater for maintaining the target above a temperature at which the residual gas is cryoabsorbed in the course of cryoabsorption of the residual gas by the cryoabsorption mechanism. 2 figs.

  1. Inter-comparison of air pollutant concentrations in different indoor environments in Hong Kong

    NASA Astrophysics Data System (ADS)

    Lee, Shun-Cheng; Guo, Hai; Li, Wai-Ming; Chan, Lo-Yin

    Indoor air quality in selected indoor environments in Hong Kong such as homes, offices, schools, shopping malls and restaurants were investigated. Average CO 2 levels and total bacteria counts in air-conditioned classrooms, shopping malls and restaurants were comparatively higher than those measured in occupied offices and homes. Elevated CO 2 levels exceeding 1000 ppm and total bacteria counts resulted from high occupancy combined with inadequate ventilation. Average PM 10 levels were usually higher indoors than outdoors in homes, shopping malls and restaurants. The highest indoor PM 10 levels were observed at investigated restaurants due to the presence of cigarette smoking and extensive use of gas stoves for cooking. The restaurants and shopping malls investigated had higher formaldehyde levels than other indoor environments when building material, smoking and internal renovation work were present. Volatile organic compounds (VOCs) in both indoor and outdoor environments mainly resulted from vehicle exhaust emissions. It was observed that interior decoration work and the use of industrial solvents in an indoor environment could significantly increase the indoor levels of VOCs.

  2. IMPACT OF AN INDOOR COOK STOVE INTERVENTION ON MEASURES OF SYSTEMIC INFLAMMATION

    EPA Science Inventory

    Background and Aims: Approximately three billion people use inefficient and poorly-vented indoor cook stoves, which can result in high indoor air pollution concentrations. Few studies have evaluated the cardiovascular effects of indoor biomass burning. Methods: In this pilot s...

  3. Development of a short path thermal desorption-gas chromatography/mass spectrometry method for the determination of polycyclic aromatic hydrocarbons in indoor air.

    PubMed

    Li, Yingjie; Xian, Qiming; Li, Li

    2017-05-12

    Polycyclic aromatic hydrocarbons (PAHs) are present in petroleum based products and are combustion by-products of organic matters. Determination of levels of PAHs in the indoor environment is important for assessing human exposure to these chemicals. A new short path thermal desorption (SPTD) gas chromatography/mass spectrometry (GC/MS) method for determining levels of PAHs in indoor air was developed. Thermal desorption (TD) tubes packed with glass beads, Carbopack C, and Carbopack B in sequence, were used for sample collection. Indoor air was sampled using a small portable pump over 7 days at 100ml/min. Target PAHs were thermally released and introduced into the GC/MS for analysis through the SPTD unit. During tube desorption, PAHs were cold trapped (-20°C) at the front end of the GC column. Thermal desorption efficiencies were 100% for PAHs with 2 and 3 rings, and 99-97% for PAHs with 4-6 rings. Relative standard deviation (RSD) values among replicate samples spiked at three different levels were around 10-20%. The detection limit of this method was at or below 0.1μg/m 3 except for naphthalene (0.61μg/m 3 ), fluorene (0.28μg/m 3 ) and phenanthrene (0.35μg/m 3 ). This method was applied to measure PAHs in indoor air in nine residential homes. The levels of PAHs in indoor air found in these nine homes are similar to indoor air values reported by others. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. What drives community adherence to indoor residual spraying (IRS) against malaria in Manhiça district, rural Mozambique: a qualitative study.

    PubMed

    Munguambe, Khátia; Pool, Robert; Montgomery, Catherine; Bavo, Carlos; Nhacolo, Ariel; Fiosse, Lina; Sacoor, Charfudin; Nhalungo, Delino; Mabunda, Samuel; Macete, Eusébio; Alonso, Pedro

    2011-11-23

    Malaria control remains a challenge in sub-Saharan Africa. In 2006, the World Health Organization (WHO) reinforced the recommendation of indoor residual spraying (IRS) with dichlorodiphenyltrichloroethane (DDT) to reduce malaria transmission. The National Malaria Control Programme has been reporting high coverage rates of IRS in Mozambique. It is important to establish to what extent these rates are a reflection of community acceptability, and to explore the factors associated with adherence, in order to recommend suitable approaches for interventions of this nature. To understand the implementation process, reception and acceptability of the IRS program in Manhiça district, Southern Mozambique. Qualitative data was collected through in-depth interviews, participant observation of IRS activities, informal interviews, and focus group discussions. Study participants comprised householders, community leaders, health care providers, sprayers, and community members. Qualitative data analysis was based on grounded theory. Secondary data from the Manhiça Demographic Surveillance System was used to complement the qualitative data. IRS was well received in most neighbourhoods. The overall coverage rates varied between 29% and 41% throughout the study period. The factors related to adherence to IRS were: immediate impact on insects in general, trust and obedience in the health authority, community leaders' influence, and acquaintance with the sprayers. Fighting malaria was not an important motivation for IRS adherence. There was a perception of limited efficacy of IRS against mosquitoes, but this did not affect adherence. Non-adherence to the intervention was mainly due to the unavailability of key householders, disagreement with the procedures, and the perception that spraying increased the burden of insects. Most respondents strongly favoured bed nets over IRS. The study suggests that the contribution of IRS to malaria and mosquito control is not entirely perceived by

  5. Anisotropic-Scale Junction Detection and Matching for Indoor Images.

    PubMed

    Xue, Nan; Xia, Gui-Song; Bai, Xiang; Zhang, Liangpei; Shen, Weiming

    Junctions play an important role in characterizing local geometrical structures of images, and the detection of which is a longstanding but challenging task. Existing junction detectors usually focus on identifying the location and orientations of junction branches while ignoring their scales, which, however, contain rich geometries of images. This paper presents a novel approach for junction detection and characterization, which especially exploits the locally anisotropic geometries of a junction and estimates its scales by relying on an a-contrario model. The output junctions are with anisotropic scales, saying that a scale parameter is associated with each branch of a junction and are thus named as anisotropic-scale junctions (ASJs). We then apply the new detected ASJs for matching indoor images, where there are dramatic changes of viewpoints and the detected local visual features, e.g., key-points, are usually insufficient and lack distinctive ability. We propose to use the anisotropic geometries of our junctions to improve the matching precision of indoor images. The matching results on sets of indoor images demonstrate that our approach achieves the state-of-the-art performance on indoor image matching.Junctions play an important role in characterizing local geometrical structures of images, and the detection of which is a longstanding but challenging task. Existing junction detectors usually focus on identifying the location and orientations of junction branches while ignoring their scales, which, however, contain rich geometries of images. This paper presents a novel approach for junction detection and characterization, which especially exploits the locally anisotropic geometries of a junction and estimates its scales by relying on an a-contrario model. The output junctions are with anisotropic scales, saying that a scale parameter is associated with each branch of a junction and are thus named as anisotropic-scale junctions (ASJs). We then apply the new

  6. Indoor Air Quality: Tools for Schools Action Kit.

    ERIC Educational Resources Information Center

    Environmental Protection Agency, Washington, DC. Indoor Air Div.

    Good indoor air quality contributes to a favorable learning environment for students, productivity for teachers and staff, and a sense of comfort, health, and well-being for all school occupants. The goal of this kit is to provide clear and easily applied guidance that will help prevent Indoor Air Quality (IAQ) problems and resolve such problems…

  7. Targeted versus standard bait station placement affects subterranean termite (Isoptera: Rhinotermitidae) infestation rates.

    PubMed

    Jones, Susan C

    2003-10-01

    A major challenge to termite baiting in soil habitats is the prolonged time that it may take for subterranean termites (Isoptera: Rhinotermitidae) to infest stations. The objective of this research study was to determine whether the location of food sources (Sentricon in-ground monitoring stations and wooden monitors) influences the likelihood of infestation by termites. In field trials conducted at 15 structures in central Ohio, standard placement of stations at 3-4.5 m intervals was compared with targeted placements based on evidence of termite activity indoors and outdoors as well as conducive moisture conditions. Termites infested significantly more targeted placements (70/374) than standard placements (35/372) around structures. At the targeted placement sites, termites infested more wooden monitors than Sentricon stations, but this was not statistically significant. This implies that placement, rather than cellulose composition, was the more important factor. Termites first infested stations/monitors an average of 38 d sooner at targeted sites than standard placement sites. This research indicates that evidence of termite activity indoors and outdoors should be a prime consideration when placing in-ground stations.

  8. INDOOR AIR QUALITY AND INHALATION EXPOSURE - SIMULATION TOOL KIT

    EPA Science Inventory

    A Microsoft Windows-based indoor air quality (IAQ) simulation software package is presented. Named Simulation Tool Kit for Indoor Air Quality and Inhalation Exposure, or IAQX for short, this package complements and supplements existing IAQ simulation programs and is desi...

  9. Mitigation of building-related polychlorinated biphenyls in indoor air of a school

    PubMed Central

    2012-01-01

    Background Sealants and other building materials sold in the U.S. from 1958 - 1971 were commonly manufactured with polychlorinated biphenyls (PCBs) at percent quantities by weight. Volatilization of PCBs from construction materials has been reported to produce PCB levels in indoor air that exceed health protective guideline values. The discovery of PCBs in indoor air of schools can produce numerous complications including disruption of normal operations and potential risks to health. Understanding the dynamics of building-related PCBs in indoor air is needed to identify effective strategies for managing potential exposures and risks. This paper reports on the efficacy of selected engineering controls implemented to mitigate concentrations of PCBs in indoor air. Methods Three interventions (ventilation, contact encapsulation, and physical barriers) were evaluated in an elementary school with PCB-containing caulk and elevated PCB concentrations in indoor air. Fluorescent light ballasts did not contain PCBs. Following implementation of the final intervention, measurements obtained over 14 months were used to assess the efficacy of the mitigation methods over time as well as temporal variability of PCBs in indoor air. Results Controlling for air exchange rates and temperature, the interventions produced statistically significant (p < 0.05) reductions in concentrations of PCBs in indoor air of the school. The mitigation measures remained effective over the course of the entire follow-up period. After all interventions were implemented, PCB levels in indoor air were associated with indoor temperature. In a "broken-stick" regression model with a node at 20°C, temperature explained 79% of the variability of indoor PCB concentrations over time (p < 0.001). Conclusions Increasing outdoor air ventilation, encapsulating caulk, and constructing a physical barrier over the encapsulated material were shown to be effective at reducing exposure concentrations of PCBs in indoor air

  10. Escherichia coli Common Pilus (ECP) Targets Arabinosyl Residues in Plant Cell Walls to Mediate Adhesion to Fresh Produce Plants*

    PubMed Central

    Rossez, Yannick; Holmes, Ashleigh; Lodberg-Pedersen, Henriette; Birse, Louise; Marshall, Jacqueline; Willats, William G. T.; Toth, Ian K.; Holden, Nicola J.

    2014-01-01

    Outbreaks of verotoxigenic Escherichia coli are often associated with fresh produce. However, the molecular basis to adherence is unknown beyond ionic lipid-flagellum interactions in plant cell membranes. We demonstrate that arabinans present in different constituents of plant cell walls are targeted for adherence by E. coli common pilus (ECP; or meningitis-associated and temperature-regulated (Mat) fimbriae) for E. coli serotypes O157:H7 and O18:K1:H7. l-Arabinose is a common constituent of plant cell wall that is rarely found in other organisms, whereas ECP is widespread in E. coli and other environmental enteric species. ECP bound to oligosaccharides of at least arabinotriose or longer in a glycan array, plant cell wall pectic polysaccharides, and plant glycoproteins. Recognition overlapped with the antibody LM13, which binds arabinanase-sensitive pectic epitopes, and showed a preferential affinity for (1→5)-α-linked l-arabinosyl residues and longer chains of arabinan as demonstrated with the use of arabinan-degrading enzymes. Functional adherence in planta was mediated by the adhesin EcpD in combination with the structural subunit, EcpA, and expression was demonstrated with an ecpR–GFP fusion and ECP antibodies. Spinach was found to be enriched for ECP/LM13 targets compared with lettuce. Specific recognition of arabinosyl residues may help explain the persistence of E. coli in the wider environment and association of verotoxigenic E. coli with some fresh produce plants by exploitation of a glycan found only in plant, not animal, cells. PMID:25320086

  11. Escherichia coli common pilus (ECP) targets arabinosyl residues in plant cell walls to mediate adhesion to fresh produce plants.

    PubMed

    Rossez, Yannick; Holmes, Ashleigh; Lodberg-Pedersen, Henriette; Birse, Louise; Marshall, Jacqueline; Willats, William G T; Toth, Ian K; Holden, Nicola J

    2014-12-05

    Outbreaks of verotoxigenic Escherichia coli are often associated with fresh produce. However, the molecular basis to adherence is unknown beyond ionic lipid-flagellum interactions in plant cell membranes. We demonstrate that arabinans present in different constituents of plant cell walls are targeted for adherence by E. coli common pilus (ECP; or meningitis-associated and temperature-regulated (Mat) fimbriae) for E. coli serotypes O157:H7 and O18:K1:H7. l-Arabinose is a common constituent of plant cell wall that is rarely found in other organisms, whereas ECP is widespread in E. coli and other environmental enteric species. ECP bound to oligosaccharides of at least arabinotriose or longer in a glycan array, plant cell wall pectic polysaccharides, and plant glycoproteins. Recognition overlapped with the antibody LM13, which binds arabinanase-sensitive pectic epitopes, and showed a preferential affinity for (1→5)-α-linked l-arabinosyl residues and longer chains of arabinan as demonstrated with the use of arabinan-degrading enzymes. Functional adherence in planta was mediated by the adhesin EcpD in combination with the structural subunit, EcpA, and expression was demonstrated with an ecpR-GFP fusion and ECP antibodies. Spinach was found to be enriched for ECP/LM13 targets compared with lettuce. Specific recognition of arabinosyl residues may help explain the persistence of E. coli in the wider environment and association of verotoxigenic E. coli with some fresh produce plants by exploitation of a glycan found only in plant, not animal, cells. © 2014 by The American Society for Biochemistry and Molecular Biology, Inc.

  12. The Residual Risk Reduction Initiative: a call to action to reduce residual vascular risk in patients with dyslipidemia.

    PubMed

    Fruchart, Jean-Charles; Sacks, Frank; Hermans, Michel P; Assmann, Gerd; Brown, W Virgil; Ceska, Richard; Chapman, M John; Dodson, Paul M; Fioretto, Paola; Ginsberg, Henry N; Kadowaki, Takashi; Lablanche, Jean-Marc; Marx, Nikolaus; Plutzky, Jorge; Reiner, Zeljko; Rosenson, Robert S; Staels, Bart; Stock, Jane K; Sy, Rody; Wanner, Christoph; Zambon, Alberto; Zimmet, Paul

    2008-11-17

    Despite achieving targets for low-density lipoprotein (LDL) cholesterol, blood pressure, and glycemia in accordance with current standards of care, patients with dyslipidemia remain at high residual risk of vascular events. Atherogenic dyslipidemia, characterized by elevated triglycerides and low levels of high-density lipoprotein (HDL) cholesterol, often with elevated apolipoprotein B and non-HDL cholesterol, is common in patients with established cardiovascular disease (CVD), type 2 diabetes mellitus, or metabolic syndrome and contributes to both macrovascular and microvascular residual risk. However, atherogenic dyslipidemia is largely underdiagnosed and undertreated in clinical practice. The Residual Risk Reduction Initiative (R3i) was established to address this highly relevant clinical issue. The aims of this position paper are (1) to highlight evidence that atherogenic dyslipidemia is associated with residual macrovascular and microvascular risk in patients at high risk for CVD, despite current standards of care for dyslipidemia and diabetes; and (2) to recommend therapeutic intervention for reducing this residual vascular risk supported by evidence and expert consensus. Lifestyle modification with nutrition and exercise is an important, effective, and underutilized first step in reducing residual vascular risk. Therapeutic intervention aimed at achievement of all lipid targets is also often required. Combination lipid-modifying therapy, with the addition of niacin, a fibrate, or omega-3 fatty acids to statin therapy, increases the probability of achieving all lipid goals. Outcomes studies are in progress to evaluate whether these combination treatment strategies translate to a clinical benefit greater than that achieved with statins alone. The R3i highlights the need to address with lifestyle and/or pharmacotherapy the high level of residual risk of CVD events and microvascular complications among patients with dyslipidemia receiving therapy for high levels

  13. Indoor radon problem in energy efficient multi-storey buildings.

    PubMed

    Yarmoshenko, I V; Vasilyev, A V; Onishchenko, A D; Kiselev, S M; Zhukovsky, M V

    2014-07-01

    Modern energy-efficient architectural solutions and building construction technologies such as monolithic concrete structures in combination with effective insulation reduce air permeability of building envelope. As a result, air exchange rate is significantly reduced and conditions for increased radon accumulation in indoor air are created. Based on radon survey in Ekaterinburg, Russia, remarkable increase in indoor radon concentration level in energy-efficient multi-storey buildings was found in comparison with similar buildings constructed before the-energy-saving era. To investigate the problem of indoor radon in energy-efficient multi-storey buildings, the measurements of radon concentration have been performed in seven modern buildings using radon monitoring method. Values of air exchange rate and other parameters of indoor climate in energy-efficient buildings have been estimated. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. Pesticides residues in okra (non-target crop) grown close to a watermelon farm in Ghana.

    PubMed

    Essumang, D K; Asare, E A; Dodoo, D K

    2013-09-01

    The study looked at the levels of pesticides in okra grown close to a watermelon farm herein referred to as a non-target crop. The watermelon received some pesticide application in the course of its cultivation, and the okra which was not meant to be sprayed was also affected by the pesticide. About 500 okra samples were collected for a period of 6 weeks and pesticides extracted with 1:1 n-hexane and dichloromethane which was analysed with Agilent 2222 GC/MS coupled with 389 auto-sampler. The results confirmed accumulation of significant levels of pesticides in the non-target crop (okra grown close to watermelon farm). Levels of organochlorine pesticides ranged from 3.10 to 7.60 μg/kg whilst the organophosphorus pesticides had levels ranging from 2.80 to 2016.80 μg/kg. The synthetic pyrethroid pesticide mean levels also ranged from 0.10 to 4.10 μg/kg and were below World Health Organization/Food and Agriculture Organization-recommended residue levels, and though not appearing to constitute a grave threat to life, their occurrence is a concern, and pre-emptive techniques must be developed to thwart the contaminations. Though the non- target crop was not treated directly with the pesticides, some level of contamination with organochlorine and organophosphorus pesticides persisted in the crops. It can be inferred that application of pesticides affected the adjoining crops, meaning that inter-cropping and mix-cropping might not be acceptable when one of the crops requires pesticide application. It is important for the farmers to be trained to ensure proper application of pesticide to minimise its impact on the health of consumers.

  15. Revised methods for estimating potential reentry exposure associated with indoor crack and crevice and perimeter application.

    PubMed

    Driver, Jeffrey H; Ross, John H; Pandian, Muhilan; Selim, Sami; Sharp, Janice K

    2013-01-01

    Surface deposition of insecticides applied as indoor residential foggers, baseboard or perimeter sprays, spot sprays, and crack-and-crevice (C&C) sprays represent pathways of unintentional, postapplication exposure for children and adults. Estimation of the magnitude of this exposure following an application event is associated with uncertainty due to many factors, including (1) surface residue deposition and distribution, (2) access to and the nature of contact with treated surfaces based on time-activity patterns of residents, and (3) the role of residue removal mechanisms such as cleaning treated surfaces, pesticide degradation or redistribution, and hand washing and bathing following contact. A comparative spatial deposition study was conducted involving broadcast, perimeter, and C&C application methods. Residues measured using a spatial grid of deposition dosimeters on floor surfaces demonstrated significantly lower residue concentrations in readily accessible areas following C&C and perimeter applications, versus broadcast treatment. Analyses of other monitoring studies support this finding. The implications of these findings are discussed for both screening-level and higher tier probabilistic postapplication, residential exposure assessment. The U.S. Environmental Protection Agency (EPA) current guidance on interpretation of deposition following C&C application is supported by data in this study and others that indicate a ratio of 10:1 for deposition for broadcast versus C&C application. However, the perimeter deposition data are quite similar to C&C deposition and do not support a 70/30 default relative to broadcast recommended by the U.S. EPA (2012).

  16. Contextual Factors, Indoor Tanning, and Tanning Dependence in Young Women

    PubMed Central

    Heckman, Carolyn J.; Darlow, Susan D.; Kloss, Jacqueline D.; Munshi, Teja; Manne, Sharon L.

    2015-01-01

    Objectives The study's purpose was to investigate the association of contextual factors such as cost, tanning accessibility, regulations, or marketing and indoor tanning or tanning dependence. Methods One hundred thirty-nine college-aged female indoor tanners completed a questionnaire between 2009 and 2011. Results Higher scores on tanning dependence and assessment in the spring/summer (versus the fall/winter) were associated with more frequent indoor tanning in the last 30 days (ps < .05). More frequent indoor tanning, greater session length, and more trouble paying for tanning were associated with higher scores on tanning dependence (ps < .05). Conclusions Public health research and practice could benefit from attention to such contextual factors as tanning cost and regulations regarding session length. PMID:25741682

  17. Development of an indoor air quality checklist for risk assessment of indoor air pollutants by semiquantitative score in nonindustrial workplaces

    PubMed Central

    Syazwan, AI; Rafee, B Mohd; Hafizan, Juahir; Azman, AZF; Nizar, AM; Izwyn, Z; Muhaimin, AA; Yunos, MA Syafiq; Anita, AR; Hanafiah, J Muhamad; Shaharuddin, MS; Ibthisham, A Mohd; Ismail, Mohd Hasmadi; Azhar, MN Mohamad; Azizan, HS; Zulfadhli, I; Othman, J

    2012-01-01

    Background To meet the current diversified health needs in workplaces, especially in nonindustrial workplaces in developing countries, an indoor air quality (IAQ) component of a participatory occupational safety and health survey should be included. Objectives The purpose of this study was to evaluate and suggest a multidisciplinary, integrated IAQ checklist for evaluating the health risk of building occupants. This IAQ checklist proposed to support employers, workers, and assessors in understanding a wide range of important elements in the indoor air environment to promote awareness in nonindustrial workplaces. Methods The general structure of and specific items in the IAQ checklist were discussed in a focus group meeting with IAQ assessors based upon the result of a literature review, previous industrial code of practice, and previous interviews with company employers and workers. Results For practicality and validity, several sessions were held to elicit the opinions of company members, and, as a result, modifications were made. The newly developed IAQ checklist was finally formulated, consisting of seven core areas, nine technical areas, and 71 essential items. Each item was linked to a suitable section in the Industry Code of Practice on Indoor Air Quality published by the Department of Occupational Safety and Health. Conclusion Combined usage of an IAQ checklist with the information from the Industry Code of Practice on Indoor Air Quality would provide easily comprehensible information and practical support. Intervention and evaluation studies using this newly developed IAQ checklist will clarify the effectiveness of a new approach in evaluating the risk of indoor air pollutants in the workplace. PMID:22570579

  18. Development of an indoor air quality checklist for risk assessment of indoor air pollutants by semiquantitative score in nonindustrial workplaces.

    PubMed

    Syazwan, Ai; Rafee, B Mohd; Hafizan, Juahir; Azman, Azf; Nizar, Am; Izwyn, Z; Muhaimin, Aa; Yunos, Ma Syafiq; Anita, Ar; Hanafiah, J Muhamad; Shaharuddin, Ms; Ibthisham, A Mohd; Ismail, Mohd Hasmadi; Azhar, Mn Mohamad; Azizan, Hs; Zulfadhli, I; Othman, J

    2012-01-01

    To meet the current diversified health needs in workplaces, especially in nonindustrial workplaces in developing countries, an indoor air quality (IAQ) component of a participatory occupational safety and health survey should be included. The purpose of this study was to evaluate and suggest a multidisciplinary, integrated IAQ checklist for evaluating the health risk of building occupants. This IAQ checklist proposed to support employers, workers, and assessors in understanding a wide range of important elements in the indoor air environment to promote awareness in nonindustrial workplaces. The general structure of and specific items in the IAQ checklist were discussed in a focus group meeting with IAQ assessors based upon the result of a literature review, previous industrial code of practice, and previous interviews with company employers and workers. For practicality and validity, several sessions were held to elicit the opinions of company members, and, as a result, modifications were made. The newly developed IAQ checklist was finally formulated, consisting of seven core areas, nine technical areas, and 71 essential items. Each item was linked to a suitable section in the Industry Code of Practice on Indoor Air Quality published by the Department of Occupational Safety and Health. Combined usage of an IAQ checklist with the information from the Industry Code of Practice on Indoor Air Quality would provide easily comprehensible information and practical support. Intervention and evaluation studies using this newly developed IAQ checklist will clarify the effectiveness of a new approach in evaluating the risk of indoor air pollutants in the workplace.

  19. High-Throughput Analytical Techniques for Determination of Residues of 653 Multiclass Pesticides and Chemical Pollutants in Tea, Part VI: Study of the Degradation of 271 Pesticide Residues in Aged Oolong Tea by Gas Chromatography-Tandem Mass Spectrometry and Its Application in Predicting the Residue Concentrations of Target Pesticides.

    PubMed

    Chang, Qiao-Ying; Pang, Guo-Fang; Fan, Chun-Lin; Chen, Hui; Wang, Zhi-Bin

    2016-07-01

    The degradation rate of 271 pesticide residues in aged Oolong tea at two spray concentrations, named a and b (a < b), were monitored for 120 days using GC-tandem MS (GC-MS/MS). To research the degradation trends and establish regression equations, determination days were plotted as horizontal ordinates and the residue concentrations of pesticide were plotted as vertical ordinates. Here, we consider the degradation equations of 271 pesticides over 40 and 120 days, summarize the degradation rates in six aspects (A-F), and discuss the degradation trends of the 271 pesticides in aged Oolong tea in detail. The results indicate that >70% of the determined pesticides coincide with the degradation regularity of trends A, B, and E, i.e., the concentration of pesticide will decrease within 4 months. Next, 20 representative pesticides were selected for further study at higher spray concentrations, named c and d (d > c > b > a), in aged Oolong tea over another 90 days. The determination days were plotted on the x-axis, and the differences between each determined result and first-time-determined value of target pesticides were plotted on the y-axis. The logarithmic function was obtained by fitting the 90-day determination results, allowing the degradation value of a target pesticide on a specific day to be calculated. These logarithmic functions at d concentration were applied to predict the residue concentrations of pesticides at c concentration. Results revealed that 70% of the 20 pesticides had the lower deviation ratios of predicted and measured results.

  20. 77 FR 37838 - Disregarded Entities and the Indoor Tanning Services Excise Tax

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-25

    ... 1545-BK38 Disregarded Entities and the Indoor Tanning Services Excise Tax AGENCY: Internal Revenue... the indoor tanning services excise tax. These regulations affect disregarded entities responsible for collecting the indoor tanning services excise tax and owners of those disregarded entities. The text of the...

  1. Impact of surface ozone interactions on indoor air chemistry: A modeling study.

    PubMed

    Kruza, M; Lewis, A C; Morrison, G C; Carslaw, N

    2017-09-01

    An INdoor air Detailed Chemical Model was developed to investigate the impact of ozone reactions with indoor surfaces (including occupants), on indoor air chemistry in simulated apartments subject to ambient air pollution. The results are consistent with experimental studies showing that approximately 80% of ozone indoors is lost through deposition to surfaces. The human body removes ozone most effectively from indoor air per square meter of surface, but the most significant surfaces for C 6 -C 10 aldehyde formation are soft furniture and painted walls owing to their large internal surfaces. Mixing ratios of between 8 and 11 ppb of C 6 -C 10 aldehydes are predicted to form in apartments in various locations in summer, the highest values are when ozone concentrations are enhanced outdoors. The most important aldehyde formed indoors is predicted to be nonanal (5-7 ppb), driven by oxidation-derived emissions from painted walls. In addition, ozone-derived emissions from human skin were estimated for a small bedroom at nighttime with concentrations of nonanal, decanal, and 4-oxopentanal predicted to be 0.5, 0.7, and 0.7 ppb, respectively. A detailed chemical analysis shows that ozone-derived surface aldehyde emissions from materials and people change chemical processing indoors, through enhanced formation of nitrated organic compounds and decreased levels of oxidants. © 2017 The Authors. Indoor Air Published by John Wiley & Sons Ltd.

  2. Risky business: Behaviors associated with indoor tanning in US high school students.

    PubMed

    Chapman, Stephanie; Ashack, Kurt; Bell, Eric; Sendelweck, Myra Ann; Dellavalle, Robert

    2017-09-15

    Understanding of associations between indoor tanning and risky health related behaviors such as sexual activity and substance abuse among high school students across the United States is incomplete. To identify risky health related behaviors among high school students utilizing indoor tanning and analyze differences between state specific data. Results from the Youth Risk Behavior Surveillance System (YRBSS) 2013 in 14 different states were analyzed. Participants were 90,414 high school students. Responses to questions assessing indoor tanning habits, sexual activity, and use of substances were analyzed. Sexual activity was associated with indoor tanning in 10 of 14 states, with Nebraska having the strongest association (adjusted odds ratio, 3.8; 95% CI, 2.4-6.2; p<0.001). Indoor tanning was also associated with use of alcohol, marijuana, ecstasy, cocaine, prescription medications, and cigarettes. Only 15 states asked students about their personal history of indoor tanning use, and Minnesota was excluded from our analysis as they administered a non-YRBS questionnaire. Additionally, our study only analyzed results from the 2013 YRBS. Lastly, our data was analyzed in 14 individual data sets, giving a high likelihood of Type 1 error. High school students utilizing indoor tanning are more likely to engage in sexual activity and substance abuse as compared to students who do not utilize indoor tanning.

  3. Indoor PM2.5 exposure in London's domestic stock: Modelling current and future exposures following energy efficient refurbishment

    NASA Astrophysics Data System (ADS)

    Shrubsole, C.; Ridley, I.; Biddulph, P.; Milner, J.; Vardoulakis, S.; Ucci, M.; Wilkinson, P.; Chalabi, Z.; Davies, M.

    2012-12-01

    Simulations using CONTAM (a validated multi-zone indoor air quality (IAQ) model) are employed to predict indoor exposure to PM2.5 in London dwellings in both the present day housing stock and the same stock following energy efficient refurbishments to meet greenhouse gas emissions reduction targets for 2050. We modelled interventions that would contribute to the achievement of these targets by reducing the permeability of the dwellings to 3 m3 m-2 h-1 at 50 Pa, combined with the introduction of mechanical ventilation and heat recovery (MVHR) systems. It is assumed that the current mean outdoor PM2.5 concentration of 13 μg m-3 decreased to 9 μg m-3 by 2050 due to emission control policies. Our primary finding was that installation of (assumed perfectly functioning) MVHR systems with permeability reduction are associated with appreciable reductions in PM2.5 exposure in both smoking and non-smoking dwellings. Modelling of the future scenario for non-smoking dwellings show a reduction in annual average indoor exposure to PM2.5 of 18.8 μg m-3 (from 28.4 to 9.6 μg m-3) for a typical household member. Also of interest is that a larger reduction of 42.6 μg m-3 (from 60.5 to 17.9 μg m-3) was shown for members exposed primarily to cooking-related particle emissions in the kitchen (cooks). Reductions in envelope permeability without mechanical ventilation produced increases in indoor PM2.5 concentrations; 5.4 μg m-3 for typical household members and 9.8 μg m-3 for cooks. These estimates of changes in PM2.5 exposure are sensitive to assumptions about occupant behaviour, ventilation system usage and the distributions of input variables (±72% for non-smoking and ±107% in smoking residences). However, if realised, they would result in significant health benefits.

  4. AIRBORNE PARTICLE SIZES AND SOURCES FOUND IN INDOOR AIR

    EPA Science Inventory

    As concern about indoor air quality (IAQ) has grown in recent years, understanding indoor aerosols has become increasingly important so that control techniques may be implemented to reduce damaging health effects and soiling problems. This paper begins with a brief look at the me...

  5. Exoskeletons and economics: indoor arthropod diversity increases in affluent neighbourhoods.

    PubMed

    Leong, Misha; Bertone, Matthew A; Bayless, Keith M; Dunn, Robert R; Trautwein, Michelle D

    2016-08-01

    In urban ecosystems, socioeconomics contribute to patterns of biodiversity. The 'luxury effect', in which wealthier neighbourhoods are more biologically diverse, has been observed for plants, birds, bats and lizards. Here, we used data from a survey of indoor arthropod diversity (defined throughout as family-level richness) from 50 urban houses and found that house size, surrounding vegetation, as well as mean neighbourhood income best predict the number of kinds of arthropods found indoors. Our finding, that homes in wealthier neighbourhoods host higher indoor arthropod diversity (consisting of primarily non-pest species), shows that the luxury effect can extend to the indoor environment. The effect of mean neighbourhood income on indoor arthropod diversity was particularly strong for individual houses that lacked high surrounding vegetation ground cover, suggesting that neighbourhood dynamics can compensate for local choices of homeowners. Our work suggests that the management of neighbourhoods and cities can have effects on biodiversity that can extend from trees and birds all the way to the arthropod life in bedrooms and basements. © 2016 The Authors.

  6. Exoskeletons and economics: indoor arthropod diversity increases in affluent neighbourhoods

    PubMed Central

    Bertone, Matthew A.; Bayless, Keith M.; Dunn, Robert R.; Trautwein, Michelle D.

    2016-01-01

    In urban ecosystems, socioeconomics contribute to patterns of biodiversity. The ‘luxury effect’, in which wealthier neighbourhoods are more biologically diverse, has been observed for plants, birds, bats and lizards. Here, we used data from a survey of indoor arthropod diversity (defined throughout as family-level richness) from 50 urban houses and found that house size, surrounding vegetation, as well as mean neighbourhood income best predict the number of kinds of arthropods found indoors. Our finding, that homes in wealthier neighbourhoods host higher indoor arthropod diversity (consisting of primarily non-pest species), shows that the luxury effect can extend to the indoor environment. The effect of mean neighbourhood income on indoor arthropod diversity was particularly strong for individual houses that lacked high surrounding vegetation ground cover, suggesting that neighbourhood dynamics can compensate for local choices of homeowners. Our work suggests that the management of neighbourhoods and cities can have effects on biodiversity that can extend from trees and birds all the way to the arthropod life in bedrooms and basements. PMID:27484644

  7. Indoor air pollution and respiratory health in the elderly.

    PubMed

    Bentayeb, Malek; Simoni, Marzia; Norback, Dan; Baldacci, Sandra; Maio, Sara; Viegi, Giovanni; Annesi-Maesano, Isabella

    2013-01-01

    Data on respiratory effects of indoor air pollution in elderly are scanty. The purpose of this review is to summarize current knowledge on adverse respiratory effects of indoor air pollution in individuals aged over 65 years, by presenting existing epidemiological evidence. Using MEDLINE database through PubMed, we identified relevant publications published between 1991 and 2011 in English on respiratory health effects of indoor air pollution in elderly (>65 years). A total of 61 studies were found and after application of the inclusion criteria: (i) epidemiologic studies published in English in peer-reviewed journals between January 1991 and December 2011, (ii) study population with age over or equal 65 years, and (iii) outcome of respiratory symptoms and disease with the exclusion of lung cancer, 33 relevant publications were selected. Most of them showed significant relationships between exposure to major indoor air pollutants and various short-term and long-term respiratory health outcomes such as wheezing, breathlessness, cough, phlegm, asthma, COPD, lung cancer and more rarely lung function decline. The most consistent relationship is found between chronic obstructive pulmonary disease (COPD) and environmental tobacco smoke (ETS). Further studies in the elderly population are needed in order to define causal relationships between exposures to indoor air pollution and underlying mechanisms in this sub-population.

  8. Wavelength-Resolved Photon Fluxes of Indoor Light Sources: Implications for HOx Production

    NASA Astrophysics Data System (ADS)

    Kowal, S.; Kahan, T.

    2017-12-01

    Only a handful of studies have considered photolytic reactions indoors because photon fluxes at short wavelengths are generally considered to be negligible. We have measured wavelength resolved photon fluxes from indoor light sources including incandescent, halogen, compact fluorescent (CFL), and light emitting diodes (LED). In addition, fluorescent tubes, used in many offices and industrial buildings, and sunlight through windows were measured. The measured photon fluxes were used to calculate photolysis rate constants for potential indoor hydroxyl and peroxy radical (OH and HO2, "HOx") precursors: acetaldehyde (CH3CHO), formaldehyde (HCHO), hydrogen peroxide (H2O2), nitrous acid (HONO) and ozone (O3). Rate constants in conjunction with typical indoor concentrations were used to predict HOx production rates under various lighting conditions. Our results illustrate that all light sources except LEDs emit light at high enough energy to photolyze HOx precursors. Under typical lighting conditions only fluorescent tubes and sunlight will initiate significant photochemical HOx formation, and HONO and HCHO will be the only molecules that will have a strong influence on HOx levels indoors. Data from our experiments can be used in indoor air models to better predict HOx levels indoors.

  9. Indoor radon mapping and its relation to geology in Hungary

    NASA Astrophysics Data System (ADS)

    Minda, Mihály; Tóth, György; Horváth, István; Barnet, Ivan; Hámori, Krisztián; Tóth, Eszter

    2009-04-01

    Indoor radon mapping may show stronger dependence on geological formations if the measured homes are one-storied houses with no basement. In Hungary, 17,244 homes were investigated on the yearly average of indoor radon concentrations; among these homes, there were 6,154, one-storied, no-basement houses. In Hungary, 21 geological units were created relevant for indoor radon index characterized by lithology, the position of the ground water table, and the gas permeability. Maps were drawn of different topography (counties, grid, geological units) and different values (maximum, mean, indoor radon indexes). A kind of standardization of houses was that only the one-storied, no-basement ones were chosen, but from geological point of view some more information was gained when the wall materials (bricks or adobe) were also taken into account. (“Adobe” is made of clay and straw in Hungary, and not burned as brick, just dried on sunshine). Enhanced indoor radon values can be observed on the bedrock of Cenozoic volcanic rocks and their eroded materials deposited on the local alluvial valleys. Another group with relatively increased indoor radon values can be connected to granite bodies. The grid method is useful for covering large state or even continental areas. For practical public use and detailed radon risk mapping geological or administrative unit-systems could yield more reasonable and useful results.

  10. Study on the Influence of Building Materials on Indoor Pollutants and Pollution Sources

    NASA Astrophysics Data System (ADS)

    Wang, Yao

    2018-01-01

    The paper summarizes the achievements and problems of indoor air quality research at home and abroad. The pollutants and pollution sources in the room are analyzed systematically. The types of building materials and pollutants are also discussed. The physical and chemical properties and health effects of main pollutants were analyzed and studied. According to the principle of mass balance, the basic mathematical model of indoor air quality is established. Considering the release rate of pollutants and indoor ventilation, a mathematical model for predicting the concentration of indoor air pollutants is derived. The model can be used to analyze and describe the variation of pollutant concentration in indoor air, and to predict and calculate the concentration of pollutants in indoor air at a certain time. The results show that the mathematical model established in this study can be used to analyze and predict the variation law of pollutant concentration in indoor air. The evaluation model can be used to evaluate the impact of indoor air quality and evaluation of current situation. Especially in the process of building and interior decoration, through pre-evaluation, it can provide reliable design parameters for selecting building materials and determining ventilation volume.

  11. Phosmet residues in an orchard and adjacent recreational area.

    PubMed

    MacNeil, J D; Hikichi, M

    1986-10-01

    Two cover sprays of phosmet were applied to an orchard adjoining a camping area and a bird sanctuary with a resident goose population. Insecticide residues were monitored on orchard leaves, orchard ground cover, ground cover in the camp-site and along the adjacent lakeshore. Despite attempts to minimize drift, significant spray residues were found outside the target area. Residues on ground cover and leaves were reduced by sprinkler irrigation subsequent to spray application.

  12. International prevalence of indoor tanning: a systematic review and meta-analysis.

    PubMed

    Wehner, Mackenzie R; Chren, Mary-Margaret; Nameth, Danielle; Choudhry, Aditi; Gaskins, Matthew; Nead, Kevin T; Boscardin, W John; Linos, Eleni

    2014-04-01

    Indoor tanning is a known carcinogen, but the scope of exposure to this hazard is not known. To summarize the international prevalence of exposure to indoor tanning. Studies were identified through systematic searches of PubMed (1966 to present), Scopus (1823 to present), and Web of Science (1898 to present) databases, last performed on March 16, 2013. We also hand searched reference lists to identify records missed by database searches and publicly available data not yet published in the scientific literature. Records reporting a prevalence of indoor tanning were eligible for inclusion. We excluded case-control studies, reports with insufficient study information, and reports of groups recruited using factors related to indoor tanning. Two independent investigators performed searches and study selection. Our search yielded 1976 unique records. After exclusions, 161 records were assessed for eligibility in full text, and 88 were included. Two independent investigators extracted data on characteristics of study participants, inclusion/exclusion criteria, data collection format, outcomes, and statistical methods. Random-effects meta-analyses were used to summarize the prevalence of indoor tanning in different age categories. We calculated the population proportional attributable risk of indoor tanning in the United States, Europe, and Australia for nonmelanoma skin cancer (NMSC) and melanoma. Ever and past-year exposure to indoor tanning. The summary prevalence of ever exposure was 35.7% (95% CI, 27.5%-44.0%) for adults, 55.0% (33.0%-77.1%) for university students, and 19.3% (14.7%-24.0%) for adolescents. The summary prevalence of past-year exposure was 14.0% (95% CI, 11.5%-16.5%) for adults, 43.1% (21.7%-64.5%) for university students, and 18.3% (12.6%-24.0%) for adolescents. These results included data from 406 696 participants. The population proportional attributable risk were 3.0% to 21.8% for NMSC and 2.6% to 9.4% for melanoma, corresponding to more than 450

  13. The status of indoor air pollution.

    PubMed Central

    Esmen, N A

    1985-01-01

    Indoor air pollution, specifically restricted in its meaning to chemicals in home indoor air environment, presents a new and probably an important challenge to the researchers of the air pollution field. The general overview of this topic suggests that the voluminous data generated in the past ten or so years have only defined the rudiments of the problem, and significant areas of research still exist. Among the important areas where information is lacking, the exposures to contaminants generated by the use of consumer products and through hobbies and crafts represent perhaps the most urgent need for substantial research. PMID:4085429

  14. Indoor chemistry: research opportunities and challenges.

    PubMed

    Nazaroff, W W; Goldstein, A H

    2015-08-01

    In this editorial, we have highlighted key research opportunities and challenges in four topical themes for indoor chemistry: human occupants as agents influencing indoor chemistry; oxidative chemistry; surface phenomena; and semivolatile organic compounds. In each case, enough prior work has been done to demonstrate the importance of the theme and to create a foundation for future studies. Extensive achievements and ongoing progress in (outdoor) atmospheric chemistry—both in the analytical methods developed and in the scientific knowledge created—also contribute to a strong foundation from which to achieve rapid research progress in this exciting new domain.

  15. Relationships among indoor, outdoor, and personal airborne Japanese cedar pollen counts.

    PubMed

    Yamamoto, Naomichi; Matsuki, Yuuki; Yokoyama, Hiromichi; Matsuki, Hideaki

    2015-01-01

    Japanese cedar pollinosis (JCP) is an important illness caused by the inhalation of airborne allergenic cedar pollens, which are dispersed in the early spring throughout the Japanese islands. However, associations between pollen exposures and the prevalence or severity of allergic symptoms are largely unknown, due to a lack of understanding regarding personal pollen exposures in relation to indoor and outdoor concentrations. This study aims to examine the relationships among indoor, outdoor, and personal airborne Japanese cedar pollen counts. We conducted a 4-year monitoring campaign to quantify indoor, outdoor, and personal airborne cedar pollen counts, where the personal passive settling sampler that has been previously validated against a volumetric sampler was used to count airborne pollen grains. A total of 256 sets of indoor, outdoor, and personal samples (768 samples) were collected from 9 subjects. Medians of the seasonally-integrated indoor-to-outdoor, personal-to-outdoor, and personal-to-indoor ratios of airborne pollen counts measured for 9 subjects were 0.08, 0.10, and 1.19, respectively. A greater correlation was observed between the personal and indoor counts (r = 0.89) than between the personal and outdoor counts (r = 0.71), suggesting a potential inaccuracy in the use of outdoor counts as a basis for estimating personal exposures. The personal pollen counts differed substantially among the human subjects (49% geometric coefficient of variation), in part due to the variability in the indoor counts that have been found as major determinants of the personal pollen counts. The findings of this study highlight the need for pollen monitoring in proximity to human subjects to better understand the relationships between pollen exposures and the prevalence or severity of pollen allergy.

  16. Indoor air pollution and cognitive function among older Mexican adults.

    PubMed

    Saenz, Joseph L; Wong, Rebeca; Ailshire, Jennifer A

    2018-01-01

    A growing body of research suggests exposure to high levels of outdoor air pollution may negatively affect cognitive functioning in older adults, but less is known about the link between indoor sources of air pollution and cognitive functioning. We examine the association between exposure to indoor air pollution and cognitive function among older adults in Mexico, a developing country where combustion of biomass for domestic energy remains common. Data come from the 2012 Wave of the Mexican Health and Aging Study. The analytic sample consists of 13 023 Mexican adults over age 50. Indoor air pollution is assessed by the reported use of wood or coal as the household's primary cooking fuel. Cognitive function is measured with assessments of verbal learning, verbal recall, attention, orientation and verbal fluency. Ordinary least squares regression is used to examine cross-sectional differences in cognitive function according to indoor air pollution exposure while accounting for demographic, household, health and economic characteristics. Approximately 16% of the sample reported using wood or coal as their primary cooking fuel, but this was far more common among those residing in the most rural areas (53%). Exposure to indoor air pollution was associated with poorer cognitive performance across all assessments, with the exception of verbal recall, even in fully adjusted models. Indoor air pollution may be an important factor for the cognitive health of older Mexican adults. Public health efforts should continue to develop interventions to reduce exposure to indoor air pollution in rural Mexico. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. A review of polychlorinated biphenyls (PCBs) pollution in indoor air environment.

    PubMed

    Dai, Qizhou; Min, Xia; Weng, Mili

    2016-10-01

    Polychlorinated biphenyls (PCBs) were widely used in industrial production due to the unique physical and chemical properties. As a kind of persistent organic pollutants, the PCBs would lead to environment pollution and cause serious problems for human health. Thus, they have been banned since the 1980s due to the environment pollution in the past years. Indoor air is the most direct and important environment medium to human beings; thus, the PCBs pollution research in indoor air is important for the protection of human health. This paper introduces the industrial application and potential harm of PCBs, summarizes the sampling, extracting, and analytical methods of environment monitoring, and compares the indoor air levels of urban areas with those of industrial areas in different countries according to various reports. This paper can provide a basic summary for PCBs pollution control in the indoor air environment. The review of PCBs pollution in indoor air in China is still limited. In this paper, we introduce the industrial application and potential harm of PCBs, summarize the sampling, extracting, and analytical methods of environment monitoring, and compare the indoor air levels of urban areas with industrial areas in different countries according to various reports.

  18. Problems In Indoor Mapping and Modelling

    NASA Astrophysics Data System (ADS)

    Zlatanova, S.; Sithole, G.; Nakagawa, M.; Zhu, Q.

    2013-11-01

    Research in support of indoor mapping and modelling (IMM) has been active for over thirty years. This research has come in the form of As-Built surveys, Data structuring, Visualisation techniques, Navigation models and so forth. Much of this research is founded on advancements in photogrammetry, computer vision and image analysis, computer graphics, robotics, laser scanning and many others. While IMM used to be the privy of engineers, planners, consultants, contractors, and designers, this is no longer the case as commercial enterprises and individuals are also beginning to apply indoor models in their business process and applications. There are three main reasons for this. Firstly, the last two decades have seen greater use of spatial information by enterprises and the public. Secondly, IMM has been complimented by advancements in mobile computing and internet communications, making it easier than ever to access and interact with spatial information. Thirdly, indoor modelling has been advanced geometrically and semantically, opening doors for developing user-oriented, context-aware applications. This reshaping of the public's attitude and expectations with regards to spatial information has realised new applications and spurred demand for indoor models and the tools to use them. This paper examines the present state of IMM and considers the research areas that deserve attention in the future. In particular the paper considers problems in IMM that are relevant to commercial enterprises and the general public, groups this paper expects will emerge as the greatest users IMM. The subject of indoor modelling and mapping is discussed here in terms of Acquisitions and Sensors, Data Structures and Modelling, Visualisation, Applications, Legal Issues and Standards. Problems are discussed in terms of those that exist and those that are emerging. Existing problems are those that are currently being researched. Emerging problems are those problems or demands that are

  19. Improved spring model-based collaborative indoor visible light positioning

    NASA Astrophysics Data System (ADS)

    Luo, Zhijie; Zhang, WeiNan; Zhou, GuoFu

    2016-06-01

    Gaining accuracy with indoor positioning of individuals is important as many location-based services rely on the user's current position to provide them with useful services. Many researchers have studied indoor positioning techniques based on WiFi and Bluetooth. However, they have disadvantages such as low accuracy or high cost. In this paper, we propose an indoor positioning system in which visible light radiated from light-emitting diodes is used to locate the position of receivers. Compared with existing methods using light-emitting diode light, we present a high-precision and simple implementation collaborative indoor visible light positioning system based on an improved spring model. We first estimate coordinate position information using the visible light positioning system, and then use the spring model to correct positioning errors. The system can be employed easily because it does not require additional sensors and the occlusion problem of visible light would be alleviated. We also describe simulation experiments, which confirm the feasibility of our proposed method.

  20. A New Indoor Positioning System Architecture Using GPS Signals.

    PubMed

    Xu, Rui; Chen, Wu; Xu, Ying; Ji, Shengyue

    2015-04-29

    The pseudolite system is a good alternative for indoor positioning systems due to its large coverage area and accurate positioning solution. However, for common Global Positioning System (GPS) receivers, the pseudolite system requires some modifications of the user terminals. To solve the problem, this paper proposes a new pseudolite-based indoor positioning system architecture. The main idea is to receive real-world GPS signals, repeat each satellite signal and transmit those using indoor transmitting antennas. The transmitted GPS-like signal can be processed (signal acquisition and tracking, navigation data decoding) by the general receiver and thus no hardware-level modification on the receiver is required. In addition, all Tx can be synchronized with each other since one single clock is used in Rx/Tx. The proposed system is simulated using a software GPS receiver. The simulation results show the indoor positioning system is able to provide high accurate horizontal positioning in both static and dynamic situations.

  1. The Health Risks of Belgian Illicit Indoor Cannabis Plantations.

    PubMed

    Vanhove, Wouter; Cuypers, Eva; Bonneure, Arne-Jan; Gotink, Joachim; Stassen, Mirna; Tytgat, Jan; Van Damme, Patrick

    2018-04-10

    We assessed the prevalence of potential health hazards to intervention staff and cannabis growers in Belgian indoor cannabis plantations. Surface mold swab samples were taken at 16 Belgian indoor plantations contained mostly Penicillium sp. and Aspergillus sp. However, their precise health impact on intervention staff and illicit growers is unclear as no molds spore concentrations were measured. Atmospheric gas monitoring in the studied cannabis plantations did not reveal dangerous toxic substances. Health symptoms were reported by 60% of 221 surveyed police, but could not be linked to specific plantation characteristics. We conclude that Belgian indoor cannabis plantations pose a potential health threat to growers and intervention staff. AS there are currently no clear safety guidelines for seizure and dismantling of Belgian indoor cannabis plantations, we recommend first responders to follow strict safety rules when entering the growth rooms, which include wearing appropriate personal protective equipment. © 2018 American Academy of Forensic Sciences.

  2. The effects of an energy efficiency retrofit on indoor air quality.

    PubMed

    Frey, S E; Destaillats, H; Cohn, S; Ahrentzen, S; Fraser, M P

    2015-04-01

    To investigate the impacts of an energy efficiency retrofit, indoor air quality and resident health were evaluated at a low-income senior housing apartment complex in Phoenix, Arizona, before and after a green energy building renovation. Indoor and outdoor air quality sampling was carried out simultaneously with a questionnaire to characterize personal habits and general health of residents. Measured indoor formaldehyde levels before the building retrofit routinely exceeded reference exposure limits, but in the long-term follow-up sampling, indoor formaldehyde decreased for the entire study population by a statistically significant margin. Indoor PM levels were dominated by fine particles and showed a statistically significant decrease in the long-term follow-up sampling within certain resident subpopulations (i.e. residents who report smoking and residents who had lived longer at the apartment complex). © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Indoor Air Quality in Apartments

    EPA Pesticide Factsheets

    Apartments can have the same indoor air problems as single-family homes because many of the pollution sources, such as the interior building materials, furnishings, and household products, are similar.

  4. Design of indoor furniture with acoustic insulation and noise reduction function

    NASA Astrophysics Data System (ADS)

    Chen, Ziqiang; Lyu, Jianhua; Chen, Ming

    2018-05-01

    In this article, the current status of noise pollution research is analyzed and indoor noise pollution hazard on human body is discussed taking noise pollution as entry point to better understand people's needs in this concern, and it comes to the conclusion that indoor furniture with noise insulation function is required; In addition, the design status and necessity of indoor furniture with noise insulation function are expounded and the material property, structure design essentials and form design are analyzed according to sound transmission principles. In the end, design case study is presented to provide an effective way for design of indoor furniture with acoustic insulation function that meets people's needs.

  5. A Robust Crowdsourcing-Based Indoor Localization System.

    PubMed

    Zhou, Baoding; Li, Qingquan; Mao, Qingzhou; Tu, Wei

    2017-04-14

    WiFi fingerprinting-based indoor localization has been widely used due to its simplicity and can be implemented on the smartphones. The major drawback of WiFi fingerprinting is that the radio map construction is very labor-intensive and time-consuming. Another drawback of WiFi fingerprinting is the Received Signal Strength (RSS) variance problem, caused by environmental changes and device diversity. RSS variance severely degrades the localization accuracy. In this paper, we propose a robust crowdsourcing-based indoor localization system (RCILS). RCILS can automatically construct the radio map using crowdsourcing data collected by smartphones. RCILS abstracts the indoor map as the semantics graph in which the edges are the possible user paths and the vertexes are the location where users may take special activities. RCILS extracts the activity sequence contained in the trajectories by activity detection and pedestrian dead-reckoning. Based on the semantics graph and activity sequence, crowdsourcing trajectories can be located and a radio map is constructed based on the localization results. For the RSS variance problem, RCILS uses the trajectory fingerprint model for indoor localization. During online localization, RCILS obtains an RSS sequence and realizes localization by matching the RSS sequence with the radio map. To evaluate RCILS, we apply RCILS in an office building. Experiment results demonstrate the efficiency and robustness of RCILS.

  6. A Robust Crowdsourcing-Based Indoor Localization System

    PubMed Central

    Zhou, Baoding; Li, Qingquan; Mao, Qingzhou; Tu, Wei

    2017-01-01

    WiFi fingerprinting-based indoor localization has been widely used due to its simplicity and can be implemented on the smartphones. The major drawback of WiFi fingerprinting is that the radio map construction is very labor-intensive and time-consuming. Another drawback of WiFi fingerprinting is the Received Signal Strength (RSS) variance problem, caused by environmental changes and device diversity. RSS variance severely degrades the localization accuracy. In this paper, we propose a robust crowdsourcing-based indoor localization system (RCILS). RCILS can automatically construct the radio map using crowdsourcing data collected by smartphones. RCILS abstracts the indoor map as the semantics graph in which the edges are the possible user paths and the vertexes are the location where users may take special activities. RCILS extracts the activity sequence contained in the trajectories by activity detection and pedestrian dead-reckoning. Based on the semantics graph and activity sequence, crowdsourcing trajectories can be located and a radio map is constructed based on the localization results. For the RSS variance problem, RCILS uses the trajectory fingerprint model for indoor localization. During online localization, RCILS obtains an RSS sequence and realizes localization by matching the RSS sequence with the radio map. To evaluate RCILS, we apply RCILS in an office building. Experiment results demonstrate the efficiency and robustness of RCILS. PMID:28420108

  7. Assessment of indoor PM2.5 in different residential environments

    NASA Astrophysics Data System (ADS)

    Yassin, Mohamed F.; AlThaqeb, Bothaina E. Y.; Al-Mutiri, Eman A. E.

    2012-09-01

    The indoor air quality (IAQ) as assessed by PM2.5 (particulate matter with an aerodynamic diameter of less than 2.5 μm) was measured at indoor settings in various residential houses which were located in different local environments across Kuwait. The indoor house settings included kitchen, living room, and bedrooms. Samples were collected from houses over 24 h. PM2.5 was estimated using a Dust-Trak personal sampler. Results were analyzed and compared with the US Environmental Protection Agencies (EPA) and World Health Organization (WHO) standards and guidelines. The results demonstrated that kitchens have the highest PM2.5 concentration probably due to cooking activities; the bedroom has the lowest PM2.5 concentration. The study shows that Kuwait indoor residential pollution is among the worst in comparison with other countries.

  8. Challenges in Flying Quadrotor Unmanned Aerial Vehicle for 3d Indoor Reconstruction

    NASA Astrophysics Data System (ADS)

    Yan, J.; Grasso, N.; Zlatanova, S.; Braggaar, R. C.; Marx, D. B.

    2017-09-01

    Three-dimensional modelling plays a vital role in indoor 3D tracking, navigation, guidance and emergency evacuation. Reconstruction of indoor 3D models is still problematic, in part, because indoor spaces provide challenges less-documented than their outdoor counterparts. Challenges include obstacles curtailing image and point cloud capture, restricted accessibility and a wide array of indoor objects, each with unique semantics. Reconstruction of indoor environments can be achieved through a photogrammetric approach, e.g. by using image frames, aligned using recurring corresponding image points (CIP) to build coloured point clouds. Our experiments were conducted by flying a QUAV in three indoor environments and later reconstructing 3D models which were analysed under different conditions. Point clouds and meshes were created using Agisoft PhotoScan Professional. We concentrated on flight paths from two vantage points: 1) safety and security while flying indoors and 2) data collection needed for reconstruction of 3D models. We surmised that the main challenges in providing safe flight paths are related to the physical configuration of indoor environments, privacy issues, the presence of people and light conditions. We observed that the quality of recorded video used for 3D reconstruction has a high dependency on surface materials, wall textures and object types being reconstructed. Our results show that 3D indoor reconstruction predicated on video capture using a QUAV is indeed feasible, but close attention should be paid to flight paths and conditions ultimately influencing the quality of 3D models. Moreover, it should be decided in advance which objects need to be reconstructed, e.g. bare rooms or detailed furniture.

  9. Organophosphate and phthalate esters in indoor air: a comparison between multi-storey buildings with high and low prevalence of sick building symptoms.

    PubMed

    Bergh, Caroline; Magnus Åberg, K; Svartengren, Magnus; Emenius, Gunnel; Östman, Conny

    2011-07-01

    An extensive study has been conducted on the prevalence of organophosphorous flame retardants/plasticizers and phthalate ester plasticizers in indoor air. The targeted substances were measured in 45 multi-storey apartment buildings in Stockholm, Sweden. The apartment buildings were classified as high or low risk with regard to the reporting of sick building symptoms (SBS) within the project Healthy Sustainable Houses in Stockholm (3H). Air samples were taken from two to four apartments per building (in total 169 apartments) to facilitate comparison within and between buildings. Association with building characteristics has been examined as well as association with specific sources by combining chemical analysis and exploratory uni- and multivariate data analysis. The study contributes to the overall perspective of levels of organophosphate and phthalate ester in indoor air enabling comparison with other studies. The results indicated little or no difference in the concentrations of the target substances between the two risk classifications of the buildings. The differences between the apartments sampled within (intra) buildings were greater than the differences between (inter) buildings. The concentrations measured in air ranged up to 1200 ng m(-3) for organophosphate esters and up to 11 000 ng m(-3) for phthalate esters. Results in terms of sources were discerned e.g. PVC flooring is a major source of benzylbutyl phthalate in indoor air.

  10. Outdoor-sleeping and other night-time activities in northern Ghana: implications for residual transmission and malaria prevention.

    PubMed

    Monroe, April; Asamoah, Obed; Lam, Yukyan; Koenker, Hannah; Psychas, Paul; Lynch, Matthew; Ricotta, Emily; Hornston, Sureyya; Berman, Amanda; Harvey, Steven A

    2015-01-28

    Despite targeted indoor residual spraying (IRS) over a six-year period and free mass distribution of long-lasting insecticide-treated nets (ITNs), malaria rates in northern Ghana remain high. Outdoor sleeping and other night-time social, cultural and economic activities that increase exposure to infective mosquito bites are possible contributors. This study was designed to document these phenomena through direct observation, and to explore the context in which they occur. During the late dry season months of February and March 2014, study team members carried out continuous household observations from dusk to dawn in one village in Ghana's Northern Region and one in Upper West Region. In-depth interviews with health workers and community residents helped supplement observational findings. Study team members completed observations of 182 individuals across 24 households, 12 households per site. Between the two sites, they interviewed 14 health workers, six community health volunteers and 28 community residents. In early evening, nearly all study participants were observed to be outdoors and active. From 18.00-23.00 hours, socializing, night school, household chores, and small-scale economic activities were common. All-night funerals, held outdoors and attended by large numbers of community members, were commonly reported and observed. Outdoor sleeping was frequently documented at both study sites, with 42% of the study population sleeping outdoors at some time during the night. While interviewees mentioned bed net use as important to malaria prevention, observed use was low for both indoor and outdoor sleeping. Net access within households was 65%, but only 17% of those with access used a net at any time during the night. Participants cited heat as the primary barrier and reported higher net use during the rainy season. Outdoor sleeping and other night-time activities were extensive, and could significantly increase malaria risk. These findings suggest that indoor

  11. Vector-control personnel’s knowledge, perceptions and practices towards insecticides used for indoor residual spraying in Limpopo Province, South Africa

    PubMed Central

    2013-01-01

    Background Contradictory arguments regarding the benefits and harm of insecticides, especially DDT, have caused concerns in different societal circles, threatening to undermine the achievements of the indoor residual spraying (IRS) programme in South Africa. These concerns were exacerbated by the screening of a documentary on South African Broadcasting Corporation (SABC) Television with anti-DDT sentiments. Consequently, Limpopo Malaria Control Programme (LMCP) Management advocated for an investigation to determine the potential effect of such campaigns on vector-control personnel’s knowledge and perceived effects of insecticides on human health, with a view to improving the educational materials designed for use in training vector-control personnel. Methods The study was a cross-sectional descriptive survey using a structured field-piloted questionnaire, administered to 233 randomly selected vector-control personnel. Ethical clearance was granted by the University of KwaZulu-Natal. Approval for the study was granted by the Department of Health, Limpopo. Participation in the study was voluntary and all respondents signed informed consent. Descriptive statistics were used to analyse the collected data. Results Most respondents (96.6%) had a positive perception of IRS as a method to control malaria. Despite their positive perception, 93.6% viewed IRS insecticides to be potentially harmful to the users. DDT was perceived to cause long-term reproductive and respiratory effects, whereas alpha-cypermethrin and deltamethrin were largely associated with skin irritation/itchiness and skin burn. Study participants were more worried about DDT’s potential effects on their reproductive system, including poor sexual performance, decline in libido, miscarriage and bearing children with genetic defects. However, none reported personal experience of bearing a child with genetic defects or miscarriage. Most anti-insecticide messages, especially relating to DDT, emanated from

  12. A Robust High-Accuracy Ultrasound Indoor Positioning System Based on a Wireless Sensor Network

    PubMed Central

    Qi, Jun; Liu, Guo-Ping

    2017-01-01

    This paper describes the development and implementation of a robust high-accuracy ultrasonic indoor positioning system (UIPS). The UIPS consists of several wireless ultrasonic beacons in the indoor environment. Each of them has a fixed and known position coordinate and can collect all the transmissions from the target node or emit ultrasonic signals. Every wireless sensor network (WSN) node has two communication modules: one is WiFi, that transmits the data to the server, and the other is the radio frequency (RF) module, which is only used for time synchronization between different nodes, with accuracy up to 1 μs. The distance between the beacon and the target node is calculated by measuring the time-of-flight (TOF) for the ultrasonic signal, and then the position of the target is computed by some distances and the coordinate of the beacons. TOF estimation is the most important technique in the UIPS. A new time domain method to extract the envelope of the ultrasonic signals is presented in order to estimate the TOF. This method, with the envelope detection filter, estimates the value with the sampled values on both sides based on the least squares method (LSM). The simulation results show that the method can achieve envelope detection with a good filtering effect by means of the LSM. The highest precision and variance can reach 0.61 mm and 0.23 mm, respectively, in pseudo-range measurements with UIPS. A maximum location error of 10.2 mm is achieved in the positioning experiments for a moving robot, when UIPS works on the line-of-sight (LOS) signal. PMID:29113126

  13. A Robust High-Accuracy Ultrasound Indoor Positioning System Based on a Wireless Sensor Network.

    PubMed

    Qi, Jun; Liu, Guo-Ping

    2017-11-06

    This paper describes the development and implementation of a robust high-accuracy ultrasonic indoor positioning system (UIPS). The UIPS consists of several wireless ultrasonic beacons in the indoor environment. Each of them has a fixed and known position coordinate and can collect all the transmissions from the target node or emit ultrasonic signals. Every wireless sensor network (WSN) node has two communication modules: one is WiFi, that transmits the data to the server, and the other is the radio frequency (RF) module, which is only used for time synchronization between different nodes, with accuracy up to 1 μ s. The distance between the beacon and the target node is calculated by measuring the time-of-flight (TOF) for the ultrasonic signal, and then the position of the target is computed by some distances and the coordinate of the beacons. TOF estimation is the most important technique in the UIPS. A new time domain method to extract the envelope of the ultrasonic signals is presented in order to estimate the TOF. This method, with the envelope detection filter, estimates the value with the sampled values on both sides based on the least squares method (LSM). The simulation results show that the method can achieve envelope detection with a good filtering effect by means of the LSM. The highest precision and variance can reach 0.61 mm and 0.23 mm, respectively, in pseudo-range measurements with UIPS. A maximum location error of 10.2 mm is achieved in the positioning experiments for a moving robot, when UIPS works on the line-of-sight (LOS) signal.

  14. Indirect health effects of relative humidity in indoor environments.

    PubMed Central

    Arundel, A V; Sterling, E M; Biggin, J H; Sterling, T D

    1986-01-01

    A review of the health effects of relative humidity in indoor environments suggests that relative humidity can affect the incidence of respiratory infections and allergies. Experimental studies on airborne-transmitted infectious bacteria and viruses have shown that the survival or infectivity of these organisms is minimized by exposure to relative humidities between 40 and 70%. Nine epidemiological studies examined the relationship between the number of respiratory infections or absenteeism and the relative humidity of the office, residence, or school. The incidence of absenteeism or respiratory infections was found to be lower among people working or living in environments with mid-range versus low or high relative humidities. The indoor size of allergenic mite and fungal populations is directly dependent upon the relative humidity. Mite populations are minimized when the relative humidity is below 50% and reach a maximum size at 80% relative humidity. Most species of fungi cannot grow unless the relative humidity exceeds 60%. Relative humidity also affects the rate of offgassing of formaldehyde from indoor building materials, the rate of formation of acids and salts from sulfur and nitrogen dioxide, and the rate of formation of ozone. The influence of relative humidity on the abundance of allergens, pathogens, and noxious chemicals suggests that indoor relative humidity levels should be considered as a factor of indoor air quality. The majority of adverse health effects caused by relative humidity would be minimized by maintaining indoor levels between 40 and 60%. This would require humidification during winter in areas with cold winter climates. Humidification should preferably use evaporative or steam humidifiers, as cool mist humidifiers can disseminate aerosols contaminated with allergens. PMID:3709462

  15. House-plant placement for indoor air purification and health benefits on asthmatics.

    PubMed

    Kim, Ho-Hyun; Yang, Ji-Yeon; Lee, Jae-Young; Park, Jung-Won; Kim, Kwang-Jin; Lim, Byung-Seo; Lee, Geon-Woo; Lee, Si-Eun; Shin, Dong-Chun; Lim, Young-Wook

    2014-01-01

    Some plants were placed in indoor locations frequented by asthmatics in order to evaluate the quality of indoor air and examine the health benefits to asthmatics. The present study classified the participants into two groups: households of continuation and households of withdrawal by a quasi-experimental design. The households of continuation spent the two observation terms with indoor plants, whereas the households of withdrawal passed the former observation terms with indoor plants and went through the latter observation term without any indoor plants. The household of continuation showed a continual decrease in the indoor concentrations of volatile organic compounds (VOCs) during the entire observation period, but the household of withdrawal performed an increase in the indoor concentrations of VOCs, except formaldehyde and toluene during the latter observation term after the decrease during the former observation term. Peak expiratory flow rate (PEFR) increased in the households of continuation with the value of 13.9 L/min in the morning and 20.6 L/ min in the evening, but decreased in the households of withdrawal with the value of -24.7 L/min in the morning and -30.2 L/min in the evening in the first experimental season. All of the households exhibited a decrease in the value of PEFR in the second experimental season. Limitations to the generalizability of findings regarding the presence of plants indoors can be seen as a more general expression of such a benefit of human-environment relations.

  16. Sources of indoor and outdoor PM2.5 concentrations in primary schools.

    PubMed

    Amato, F; Rivas, I; Viana, M; Moreno, T; Bouso, L; Reche, C; Àlvarez-Pedrerol, M; Alastuey, A; Sunyer, J; Querol, X

    2014-08-15

    Children spend a third of their day in the classroom, where air pollution levels may differ substantially from those outdoors due to specific indoor sources. Air pollution exposure assessments based on atmospheric particle mass measured outdoors may therefore have little to do with the daily PM dose received by school children. This study aims to investigate outdoor and indoor sources of PM2.5 measured at 39 primary schools in Barcelona during 2012. On average 47% of indoor PM2.5 measured concentrations was found to be generated indoors due to continuous resuspension of soil particles (13%) and a mixed source (34%) comprising organic (skin flakes, clothes fibers, possible condensation of VOCs) and Ca-rich particles (from chalk and building deterioration). Emissions from seven outdoor sources penetrated easily indoors being responsible for the remaining 53% of measured PM2.5 indoors. Unpaved playgrounds were found to increase mineral contributions in classrooms by 5-6 μg/m(3) on average with respect to schools with paved playgrounds. Weekday traffic contributions varied considerably across Barcelona within ranges of 1-14 μg/m(3) outdoor and 1-10 μg/m(3) indoor. Indoors, traffic contributions were significantly higher (more than twofold) for classrooms with windows oriented directly to the street, rather than to the interior of the block or to playgrounds. This highlights the importance of urban planning in order to reduce children's exposure to traffic emissions. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Mobile indoor localization using Kalman filter and trilateration technique

    NASA Astrophysics Data System (ADS)

    Wahid, Abdul; Kim, Su Mi; Choi, Jaeho

    2015-12-01

    In this paper, an indoor localization method based on Kalman filtered RSSI is presented. The indoor communications environment however is rather harsh to the mobiles since there is a substantial number of objects distorting the RSSI signals; fading and interference are main sources of the distortion. In this paper, a Kalman filter is adopted to filter the RSSI signals and the trilateration method is applied to obtain the robust and accurate coordinates of the mobile station. From the indoor experiments using the WiFi stations, we have found that the proposed algorithm can provide a higher accuracy with relatively lower power consumption in comparison to a conventional method.

  18. Extracting Topological Relations Between Indoor Spaces from Point Clouds

    NASA Astrophysics Data System (ADS)

    Tran, H.; Khoshelham, K.; Kealy, A.; Díaz-Vilariño, L.

    2017-09-01

    3D models of indoor environments are essential for many application domains such as navigation guidance, emergency management and a range of indoor location-based services. The principal components defined in different BIM standards contain not only building elements, such as floors, walls and doors, but also navigable spaces and their topological relations, which are essential for path planning and navigation. We present an approach to automatically reconstruct topological relations between navigable spaces from point clouds. Three types of topological relations, namely containment, adjacency and connectivity of the spaces are modelled. The results of initial experiments demonstrate the potential of the method in supporting indoor navigation.

  19. Very volatile organic compounds: an understudied class of indoor air pollutants.

    PubMed

    Salthammer, T

    2016-02-01

    Very volatile organic compounds (VVOCs), as categorized by the WHO, are an important subgroup of indoor pollutants and cover a wide spectrum of chemical substances. Some VVOCs are components of products commonly used indoors, some result from chemical reactions and some are reactive precursors of secondary products. Nevertheless, there is still no clear and internationally accepted definition of VVOCs. Current approaches are based on the boiling point, and the saturation vapor pressure or refer to analytical procedures. A significant problem is that many airborne VVOCs cannot be routinely analyzed by the usually applied technique of sampling on Tenax TA® followed by thermal desorption GC/MS or by DNPH-sampling/HPLC/UV. Some VVOCs are therefore often neglected in indoor-related studies. However, VVOCs are of high significance for indoor air quality assessment and there is need for their broader consideration in measurement campaigns and material emission testing. © 2014 The Authors. Indoor Air published by John Wiley & Sons Ltd.

  20. Indoor air quality investigation and health risk assessment at correctional institutions.

    PubMed

    Ofungwu, Joseph

    2005-04-01

    A comprehensive indoor air-quality (IAQ) investigation was conducted at a state correctional facility in New Jersey, USA with a lengthy history of IAQ problems. The IAQ investigation comprised preliminary indoor air screening using direct readout instrumentation, indoor air/surface wipe sampling and laboratory analysis, as well as a heating, ventilation, and air-conditioning system evaluation, and a building envelope survey. In addition to air sampling, a human health risk assessment was performed to evaluate the potential for exposure to site-related air contaminants with respect to the inmate and worker populations. The risk assessment results for the prison facility indicated the potential for significant health risks for the inmate population, possibly reflecting the effects of their confinement and extended exposure to indoor air contaminants, as compared to the prison guard and worker population. Based on the results of the risk assessment, several mitigation measures are recommended to minimize prison population health risks and improve indoor air quality at prison facilities.