Sample records for targeted intraoperative radiotherapy

  1. The role of intraoperative radiotherapy in solid tumors.

    PubMed

    Skandarajah, A R; Lynch, A C; Mackay, J R; Ngan, S; Heriot, A G

    2009-03-01

    Combined multimodality therapy is becoming standard treatment for many solid tumors, but the role of intraoperative radiotherapy in the management of solid tumors remains uncertain. The aim is to review the indication, application, and outcomes of intraoperative radiotherapy in the management of nongynecological solid tumors. A literature search was performed using Medline, Embase, Ovid, and Cochrane database for studies between 1965 and 2008 assessing intraoperative radiotherapy, using the keywords "intraoperative radiotherapy," "colorectal cancer," "breast cancer," "gastric cancer," "pancreatic cancer," "soft tissue tumor," and "surgery." Only publications in English with available abstracts and regarding adult humans were included, and the evidence was critically evaluated. Our search retrieved 864 publications. After exclusion of nonclinical papers, duplicated papers and exclusion of brachytherapy papers, 77 papers were suitable to assess the current role of intraoperative radiotherapy. The clinical application and evidence base of intraoperative radiotherapy for each cancer is presented. Current studies in all common cancers show an additional benefit in local recurrence rates when intraoperative radiotherapy is included in the multimodal treatment. However, intraoperative radiotherapy may not improve overall survival and has significant morbidity depending on the site of the tumor. Intraoperative radiotherapy does have a role in the multidisciplinary management of solid tumors, but further studies are required to more precisely determine the extent of benefit.

  2. Intraoperative radiotherapy. Literature updating with an overview of results presented at the 6th International Symposium of Intraoperative Radiation Therapy.

    PubMed

    Calvo, F A; Santos, M; Azinovic, I

    1998-01-01

    Intraoperative radiotherapy is a technique that can be integrated into multidisciplinary treatment strategies in oncology. A radiation boost delivered with high energy electron beams can intensify locoregional antitumor therapy in patients undergoing cancer surgery. Intraoperative radiotherapy can increase the therapeutic index of the conventional combination of surgery and radiotherapy by improving the precision of radiation dose location, while decreasing the normal tissue damage in mobile structures and enhancing the biological effect of radiation when combined with surgical debulking. Intraoperative radiotherapy has been extensively investigated in clinical oncology in the last 15 years. Commercially available linear accelerators require minimal changes to be suitable for intraoperative radiotherapy. Its successful implementation in clinical protocols depends on the support given by the single institutions and on a clinical research-oriented mentality. Tumors where intraoperative radiotherapy as a treatment component has shown promising rates of local control include locally advanced rectal, gastric and gynecologic cancer, bone and soft tissue sarcoma. Intraoperative radiotherapy can be applied to brain tumors, head and neck cancer, NSCLC and pancreatic carcinoma.

  3. In Vivo Dosimetry for Single-Fraction Targeted Intraoperative Radiotherapy (TARGIT) for Breast Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eaton, David J., E-mail: davideaton@nhs.net; Best, Bronagh; Brew-Graves, Chris

    Purpose: In vivo dosimetry provides an independent check of delivered dose and gives confidence in the introduction or consistency of radiotherapy techniques. Single-fraction intraoperative radiotherapy of the breast can be performed with the Intrabeam compact, mobile 50 kV x-ray source (Carl Zeiss Surgical, Oberkochen, Germany). Thermoluminescent dosimeters (TLDs) can be used to estimate skin doses during these treatments. Methods and Materials: Measurements of skin doses were taken using TLDs for 72 patients over 3 years of clinical treatments. Phantom studies were also undertaken to assess the uncertainties resulting from changes in beam quality and backscatter conditions in vivo. Results: Themore » mean measured skin dose was 2.9 {+-} 1.6 Gy, with 11% of readings higher than the prescription dose of 6 Gy, but none of these patients showed increased complications. Uncertainties due to beam hardening and backscatter reduction were small compared with overall accuracy. Conclusions: TLDs are a useful and effective method to measure in vivo skin doses in intraoperative radiotherapy and are recommended for the initial validation or any modification to the delivery of this technique. They are also an effective tool to show consistent and safe delivery on a more frequent basis or to determine doses to other critical structures as required.« less

  4. Sphere of equivalence--a novel target volume concept for intraoperative radiotherapy using low-energy X rays.

    PubMed

    Herskind, Carsten; Griebel, Jürgen; Kraus-Tiefenbacher, Uta; Wenz, Frederik

    2008-12-01

    Accelerated partial breast radiotherapy with low-energy photons from a miniature X-ray machine is undergoing a randomized clinical trial (Targeted Intra-operative Radiation Therapy [TARGIT]) in a selected subgroup of patients treated with breast-conserving surgery. The steep radial dose gradient implies reduced tumor cell control with increasing depth in the tumor bed. The purpose was to compare the expected risk of local recurrence in this nonuniform radiation field with that after conventional external beam radiotherapy. The relative biologic effectiveness of low-energy photons was modeled using the linear-quadratic formalism including repair of sublethal lesions during protracted irradiation. Doses of 50-kV X-rays (Intrabeam) were converted to equivalent fractionated doses, EQD2, as function of depth in the tumor bed. The probability of local control was estimated using a logistic dose-response relationship fitted to clinical data from fractionated radiotherapy. The model calculations show that, for a cohort of patients, the increase in local control in the high-dose region near the applicator partly compensates the reduction of local control at greater distances. Thus a "sphere of equivalence" exists within which the risk of recurrence is equal to that after external fractionated radiotherapy. The spatial distribution of recurrences inside this sphere will be different from that after conventional radiotherapy. A novel target volume concept is presented here. The incidence of recurrences arising in the tumor bed around the excised tumor will test the validity of this concept and the efficacy of the treatment. Recurrences elsewhere will have implications for the rationale of TARGIT.

  5. Threshold dose for peripheral neuropathy following intraoperative radiotherapy (IORT) in a large animal model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kinsella, T.J.; DeLuca, A.M.; Barnes, M.

    1991-04-01

    Radiation injury to peripheral nerve is a dose-limiting toxicity in the clinical application of intraoperative radiotherapy, particularly for pelvic and retroperitoneal tumors. Intraoperative radiotherapy-related peripheral neuropathy in humans receiving doses of 20-25 Gy is manifested as a mixed motor-sensory deficit beginning 6-9 months following treatment. In a previous experimental study of intraoperative radiotherapy-related neuropathy of the lumbro-sacral plexus, an approximate inverse linear relationship was reported between the intraoperative dose (20-75 Gy range) and the time to onset of hind limb paresis (1-12 mos following intraoperative radiotherapy). The principal histological lesion in irradiated nerve was loss of large nerve fibers andmore » perineural fibrosis without significant vascular injury. Similar histological changes in irradiated nerves were found in humans. To assess peripheral nerve injury to lower doses of intraoperative radiotherapy in this same large animal model, groups of four adult American Foxhounds received doses of 10, 15, or 20 Gy to the right lumbro-sacral plexus and sciatic nerve using 9 MeV electrons. The left lumbro-sacral plexus and sciatic nerve were excluded from the intraoperative field to allow each animal to serve as its own control. Following treatment, a complete neurological exam, electromyogram, and nerve conduction studies were performed monthly for 1 year. Monthly neurological exams were performed in years 2 and 3 whereas electromyogram and nerve conduction studies were performed every 3 months during this follow-up period. With follow-up of greater than or equal to 42 months, no dog receiving 10 or 15 Gy IORT shows any clinical or laboratory evidence of peripheral nerve injury. However, all four dogs receiving 20 Gy developed right hind limb paresis at 8, 9, 9, and 12 mos following intraoperative radiotherapy.« less

  6. Health economics of targeted intraoperative radiotherapy (TARGIT-IORT) for early breast cancer: a cost-effectiveness analysis in the United Kingdom.

    PubMed

    Vaidya, Anil; Vaidya, Param; Both, Brigitte; Brew-Graves, Chris; Bulsara, Max; Vaidya, Jayant S

    2017-08-17

    The clinical effectiveness of targeted intraoperative radiotherapy (TARGIT-IORT) has been confirmed in the randomised TARGIT-A (targeted intraoperative radiotherapy-alone) trial to be similar to a several weeks' course of whole-breast external-beam radiation therapy (EBRT) in patients with early breast cancer. This study aims to determine the cost-effectiveness of TARGIT-IORT to inform policy decisions about its wider implementation. TARGIT-A randomised clinical trial (ISRCTN34086741) which compared TARGIT with traditional EBRT and found similar breast cancer control, particularly when TARGIT was given simultaneously with lumpectomy. Cost-utility analysis using decision analytic modelling by a Markov model. A cost-effectiveness Markov model was developed using TreeAge Pro V.2015. The decision analytic model compared two strategies of radiotherapy for breast cancer in a hypothetical cohort of patients with early breast cancer based on the published health state transition probability data from the TARGIT-A trial. Analysis was performed for UK setting and National Health Service (NHS) healthcare payer's perspective using NHS cost data and treatment outcomes were simulated for both strategies for a time horizon of 10 years. Model health state utilities were drawn from the published literature. Future costs and effects were discounted at the rate of 3.5%. To address uncertainty, one-way and probabilistic sensitivity analyses were performed. Quality-adjusted life-years (QALYs). In the base case analysis, TARGIT-IORT was a highly cost-effective strategy yielding health gain at a lower cost than its comparator EBRT. Discounted TARGIT-IORT and EBRT costs for the time horizon of 10 years were £12 455 and £13 280, respectively. TARGIT-IORT gained 0.18 incremental QALY as the discounted QALYs gained by TARGIT-IORT were 8.15 and by EBRT were 7.97 showing TARGIT-IORT as a dominant strategy over EBRT. Model outputs were robust to one-way and probabilistic sensitivity analyses

  7. Radiation-related quality of life parameters after targeted intraoperative radiotherapy versus whole breast radiotherapy in patients with breast cancer: results from the randomized phase III trial TARGIT-A.

    PubMed

    Welzel, Grit; Boch, Angela; Sperk, Elena; Hofmann, Frank; Kraus-Tiefenbacher, Uta; Gerhardt, Axel; Suetterlin, Marc; Wenz, Frederik

    2013-01-07

    Intraoperative radiotherapy (IORT) is a new treatment approach for early stage breast cancer. This study reports on the effects of IORT on radiation-related quality of life (QoL) parameters. Two hundred and thirty women with stage I-III breast cancer (age, 31 to 84 years) were entered into the study. A single-center subgroup of 87 women from the two arms of the randomized phase III trial TARGIT-A (TARGeted Intra-operative radioTherapy versus whole breast radiotherapy for breast cancer) was analyzed. Furthermore, results were compared to non-randomized control groups: n = 90 receiving IORT as a tumor bed boost followed by external beam whole breast radiotherapy (EBRT) outside of TARGIT-A (IORT-boost), and n = 53 treated with EBRT followed by an external-beam boost (EBRT-boost). QoL was collected using the European Organization for Research and Treatment of Cancer Quality of Life Questionnaires C30 (QLQ-C30) and BR23 (QLQ-BR23). The mean follow-up period in the TARGIT-A groups was 32 versus 39 months in the non-randomized control groups. Patients receiving IORT alone reported less general pain (21.3 points), breast (7.0 points) and arm (15.1 points) symptoms, and better role functioning (78.7 points) as patients receiving EBRT (40.9; 19.0; 32.8; and 60.5 points, respectively, P < 0.01). Patients receiving IORT alone also had fewer breast symptoms than TARGIT-A patients receiving IORT followed by EBRT for high risk features on final pathology (IORT-EBRT; 7.0 versus 29.7 points, P < 0.01). There were no significant differences between TARGIT-A patients receiving IORT-EBRT compared to non-randomized IORT-boost or EBRT-boost patients and patients receiving EBRT without a boost. In the randomized setting, important radiation-related QoL parameters after IORT were superior to EBRT. Non-randomized comparisons showed equivalent parameters in the IORT-EBRT group and the control groups.

  8. Intraoperative radiotherapy in combined treatment of sinonasal malignant tumors

    NASA Astrophysics Data System (ADS)

    Novikov, V. A.; Gribova, O. V.; Vasiljev, R. V.; Choynzonov, E. L.; Shtin, V. I.; Shiianova, A. A.; Surkova, P. V.; Starceva, Zh. A.; Shilova, O. G.

    2017-09-01

    Obvious advantage of IORT (intraoperative radiotherapy) is that the radiation source is delivered directly to the bed of the tumor during surgery, thus avoiding the negative impact on the skin, subcutaneous tissue and reducing the risk of fibrosis. Sinonasal tumors—a convenient object for intraoperative radiotherapy application (surface location, relatively small size tumors, good operational access). The surface location and comparatively small size of neoplasms, good operational access provide an efficient and accurate transfer of the electron beam to the postoperative cavity to increase the irradiation dose in the areas of the most probable recurrence, which makes the tumors of this localization a convenient object for the use of the intraoperative radiation therapy. The treatment was conducted using a mobile compact betatron (MIB-6E), 10-12 Gy single dose. IORT session extends surgery period by 30 min. There were no pathological clinical and laboratory reactions on IORT in the early postoperative period. Carrying out the procedure is possible in various standard operating rooms. It does not require special security measures for the patients and the staff. IORT with the help of electron beam allows avoiding post-radiation reactions and achieving a 5-year—disease-free survival of 66% of the patients. IORT session is possible through a minimal incision during organ preservation surgeries. Evident economic feasibility provides the prospects of applying IORT in the clinical practice.

  9. Targeted Intraoperative Radiotherapy for Breast Cancer in Patients in Whom External Beam Radiation Is Not Possible

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keshtgar, Mohammed R.S., E-mail: m.keshtgar@ucl.ac.u; Vaidya, Jayant S.; Tobias, Jeffrey S.

    2011-05-01

    Purpose: External beam radiation therapy (EBRT) following wide local excision of the primary tumor is the standard treatment in early breast cancer. In some circumstances this procedure is not possible or is contraindicated or difficult. The purpose of this study was to determine the safety and efficacy of targeted intraoperative radiotherapy (TARGIT) when EBRT is not feasible. Methods and Materials: We report our experience with TARGIT in three centers (Australia, Germany, and the United Kingdom) between 1999 and 2008. Patients at these centers received a single radiation dose of 20 Gy to the breast tissue in contact with the applicatormore » (or 6 Gy at 1-cm distance), as they could not be given EBRT and were keen to avoid mastectomy. Results: Eighty patients were treated with TARGIT. Reasons for using TARGIT were 21 patients had previously received EBRT, and 31 patients had clinical reasons such as systemic lupus erythematosus, motor neuron disease, Parkinson's disease, ankylosing spondylitis, morbid obesity, and cardiovascular or severe respiratory disease. Three of these patients received percutaneous radiotherapy without surgery; 28 patients were included for compelling personal reasons, usually on compassionate grounds. After a median follow-up of 38 months, only two local recurrences were observed, an annual local recurrence rate of 0.75% (95% confidence interval, 0.09%-2.70%). Conclusions: While we await the results of the randomized trial (over 2,000 patients have already been recruited), TARGIT is an acceptable option but only in highly selected cases that cannot be recruited in the trial and in whom EBRT is not feasible/possible.« less

  10. Intraoperative radiotherapy and colorectal cancer.

    PubMed

    Yeung, J M C; Ngan, S; Lynch, C; Heriot, A G

    2010-04-01

    Intraoperative radiotherapy (IORT) is a highly specialized component of multidisciplinary management of advanced and recurrent colorectal cancer. The aim of this review was to assess its role and effectiveness in the management of colorectal cancer. A literature search was performed using Medline, Embase, Ovid and Cochrane to identify English language studies which have used IORT in the multidisciplinary management of primary and recurrent colon and rectal cancers. Improved survival and local control in patients with involved surgical margins treated with IORT have been shown in many studies, but these results have been mainly from retrospective studies. There is associated morbidity from IORT. IORT does have a role in the management of colorectal cancer. Further research needs to be performed to optimize the application of this therapy.

  11. Single-Fraction Intraoperative Radiotherapy for Breast Cancer: Early Cosmetic Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beal, Kathryn; McCormick, Beryl; Zelefsky, Michael J.

    2007-09-01

    Purpose: To evaluate the cosmetic outcome of patients treated with wide local excision and intraoperative radiotherapy for early-stage breast cancer. Methods and Materials: A total of 50 women were treated on a pilot study to evaluate the feasibility of intraoperative radiotherapy at wide local excision. The eligibility criteria included age >60, tumor size {<=}2.0 cm, clinically negative lymph nodes, and biopsy-established diagnosis. After wide local excision, a custom breast applicator was placed in the excision cavity, and a dose of 20 Gy was prescribed to a depth of 1 cm. After 18 patients were treated, the dose was constrained laterallymore » to 18 Gy. The cosmetic outcome was evaluated by photographs at baseline and at 6 and 12 months postoperatively. Four examiners graded the photographs for symmetry, edema, discoloration, contour, and scarring. The grades were evaluated in relationship to the volume of irradiated tissue, tumor location, and dose at the lateral aspects of the cavity. Results: The median volume of tissue receiving 100% of the prescription dose was 47 cm{sup 3} (range, 20-97 cm{sup 3}). Patients with {<=}47 cm{sup 3} of treated tissue had better cosmetic outcomes than did the women who had >47 cm{sup 3} of treated tissue. Women who had received 18 Gy at the lateral aspects of their cavities had better cosmetic outcomes than did women who had received 20 Gy at the lateral aspects. When comparing the 6- and 12-month results, the scores remained stable for 63%, improved for 17%, and worsened for 20%. Conclusion: Intraoperative radiotherapy appears feasible for selected patients. A favorable cosmetic outcome appears to be related to a smaller treatment volume. The cosmetic outcome is acceptable, although additional follow-up is necessary.« less

  12. Intraoperative radiotherapy in elderly patients with breast cancer: Is there a clinical applicability? Review of the current evidence.

    PubMed

    Esposito, Emanuela; Compagna, Rita; Rinaldo, Massimo; Falivene, Sara; Ravo, Vincenzo; Amato, Bruno; Muto, Paolo; D'Aiuto, Massimiliano

    2016-09-01

    Screening and adjuvant postoperative therapies have increased survival amongst women with breast cancer, but these tools are seldom applied in elderly patients. Higher rates of local recurrence occur in those elderly patients who avoid radiotherapy. TARGIT-A and ELIOT trials has been reported to not to be inferior to external beam RT in suitable subgroups of patients. The TARGIT-Elderly trial has been launched in order to confirm the efficacy of intraoperative radiotherapy (IORT) in a well selected group of elderly patients who are more likely to decline radiation treatment. Current evidence of the medical literature on the clinical reliability and applicability of intraoperative radiotherapy amongst older women diagnosed with early breast cancer is after summarized. Literature databases were searched up to June 2015. Terms used to retrieve articles were 'breast cancer', 'elderly', 'intraoperative radiotherapy', 'IORT' and 'IOERT'. Elderly patients with pT1N0 tumours are regarded to be suitable for IORT according to ASTRO and GEC-ESTRO recommendations, respectively. In the light of the medical literature we can assume that patients benefit from postoperative radiation therapy, but we still do not know who can be spared from it. These issues emphasize the urgent need to develop and support clinical trials for this older population of breast cancer patients. Whether radiotherapy is beneficial in elderly still remains a matter of debate. IORT along with BCS in a selected subgroup of patients (>70years, pT1N0 tumours) could represent a valid option for a better local control. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  13. Implementation of an intraoperative electron radiotherapy in vivo dosimetry program.

    PubMed

    López-Tarjuelo, Juan; Morillo-Macías, Virginia; Bouché-Babiloni, Ana; Boldó-Roda, Enrique; Lozoya-Albacar, Rafael; Ferrer-Albiach, Carlos

    2016-03-15

    Intraoperative electron radiotherapy (IOERT) is a highly selective radiotherapy technique which aims to treat restricted anatomic volumes during oncological surgery and is now the subject of intense re-evaluation. In vivo dosimetry has been recommended for IOERT and has been identified as a risk-reduction intervention in the context of an IOERT risk analysis. Despite reports of fruitful experiences, information about in vivo dosimetry in intraoperative radiotherapy is somewhat scarce. Therefore, the aim of this paper is to report our experience in developing a program of in vivo dosimetry for IOERT, from both multidisciplinary and practical approaches, in a consistent patient series. We also report several current weaknesses. Reinforced TN-502RDM-H mobile metal oxide semiconductor field effect transistors (MOSFETs) and Gafchromic MD-55-2 films were used as a redundant in vivo treatment verification system with an Elekta Precise fixed linear accelerator for calibrations and treatments. In vivo dosimetry was performed in 45 patients in cases involving primary tumors or relapses. The most frequent primary tumors were breast (37 %) and colorectal (29 %), and local recurrences among relapses was 83 %. We made 50 attempts to measure with MOSFETs and 48 attempts to measure with films in the treatment zones. The surgical team placed both detectors with supervision from the radiation oncologist and following their instructions. The program was considered an overall success by the different professionals involved. The absorbed doses measured with MOSFETs and films were 93.8 ± 6.7 % and 97.9 ± 9.0 % (mean ± SD) respectively using a scale in which 90 % is the prescribed dose and 100 % is the maximum absorbed dose delivered by the beam. However, in 10 % of cases we experienced dosimetric problems due to detector misalignment, a situation which might be avoided with additional checks. The useful MOSFET lifetime length and the film sterilization procedure should also be

  14. Intraoperative Radiotherapy for Parotid Cancer: A Single-Institution Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zeidan, Youssef H., E-mail: youssefzaidan@gmail.com; Shiue, Kevin; Weed, Daniel

    2012-04-01

    Purpose: Our practice policy has been to provide intraoperative radiotherapy (IORT) at resection to patients with head-and-neck malignancies considered to be at high risk of recurrence. The purpose of the present study was to review our experience with the use of IORT for primary or recurrent cancer of the parotid gland. Methods and Materials: Between 1982 and 2007, 96 patients were treated with gross total resection and IORT for primary or recurrent cancer of the parotid gland. The median age was 62.9 years (range, 14.3-88.1). Of the 96 patients, 33 had previously undergone external beam radiotherapy as a component ofmore » definitive therapy. Also, 34 patients had positive margins after surgery, and 40 had perineural invasion. IORT was administered as a single fraction of 15 or 20 Gy with 4-6-MeV electrons. The median follow-up period was 5.6 years. Results: Only 1 patient experienced local recurrence, 19 developed regional recurrence, and 12 distant recurrence. The recurrence-free survival rate at 1, 3, and 5 years was 82.0%, 68.5%, and 65.2%, respectively. The 1-, 3-, and 5-year overall survival rate after surgery and IORT was 88.4%, 66.1%, and 56.2%, respectively. No perioperative fatalities occurred. Complications developed in 26 patients and included vascular complications in 7, trismus in 6, fistulas in 4, radiation osteonecrosis in 4, flap necrosis in 2, wound dehiscence in 2, and neuropathy in 1. Of these 26 patients, 12 had recurrent disease, and 8 had undergone external beam radiotherapy before IORT. Conclusions: IORT results in effective local disease control at acceptable levels of toxicity and should be considered for patients with primary or recurrent cancer of the parotid gland.« less

  15. Design, construction and performance evaluation of the target tissue thickness measurement system in intraoperative radiotherapy for breast cancer

    NASA Astrophysics Data System (ADS)

    Yazdani, Mohammad Reza; Setayeshi, Saeed; Arabalibeik, Hossein; Akbari, Mohammad Esmaeil

    2017-05-01

    Intraoperative electron radiation therapy (IOERT), which uses electron beams for irradiating the target directly during the surgery, has the advantage of delivering a homogeneous dose to a controlled layer of tissue. Since the dose falls off quickly below the target thickness, the underlying normal tissues are spared. In selecting the appropriate electron energy, the accuracy of the target tissue thickness measurement is critical. In contrast to other procedures applied in IOERT, the routine measurement method is considered to be completely traditional and approximate. In this work, a novel mechanism is proposed for measuring the target tissue thickness with an acceptable level of accuracy. An electronic system has been designed and manufactured with the capability of measuring the tissue thickness based on the recorded electron density under the target. The results indicated the possibility of thickness measurement with a maximum error of 2 mm for 91.35% of data. Aside from system limitation in estimating the thickness of 5 mm phantom, for 88.94% of data, maximum error is 1 mm.

  16. Role of intraoperative radiotherapy in the treatment of sacral chordoma.

    PubMed

    Jullien-Petrelli, Ariel Christian; García-Sabrido, J L; Orue-Echebarria, M I; Lozano, P; Álvarez, A; Serrano, J; Calvo, F M; Calvo-Haro, J A; Lasso, J M; Asencio, J M

    2018-04-01

    Sacral chordoma is a rare entity with high local recurrence rates when complete resection is not achieved. To date, there are no series available in literature combining surgery and intraoperative radiotherapy (IORT). The objective of this study was to report the experience of our center in the management of sacral chordoma combining radical resection with both external radiotherapy and IORT. This is a retrospective case series. The patient sample included 15 patients with sacral chordoma resected in our center from 1998 to 2015. The outcome measures were overall survival (OS), disease-free survival (DFS), and rates of local and distant recurrences. We retrospectively reviewed the records of all the patients with sacral chordoma resected in our center from 1998 to December 2015. Overall survival, DFS, and rates of local and distant recurrences were calculated. Results between patients treated with or without IORT were compared. A total of 15 patients were identified: 8 men and 7 women. The median age was 59 years (range 28-77). Intraoperative radiotherapy was applied in nine patients and six were treated with surgical resection without IORT. In 13 patients, we performed the treatment of the primary tumor, and in two patients, we performed the treatment of recurrence disease. A posterior approach was used in four patients. Wide surgical margins (zero residue) were achieved in six patients, marginal margins (microscopic residue) were achieved in seven patients, and there were no patients with intralesional (R2) margins. At a median follow-up of 38 months (range 11-209 months), the 5-year OS in the IORT group was 100% versus 53% in the group of non-IORT (p=.05). The median DFS in the IORT group was 85 months, and that in the non-IORT group was 41 months. In the group without IORT, two patients died and nobody died during the follow-up in the group treated with IORT. High-sacrectomy treated patients had a median survival of 41 months, and low-sacrectomy treated

  17. Immunotherapy Combined with Large Fractions of Radiotherapy: Stereotactic Radiosurgery for Brain Metastases—Implications for Intraoperative Radiotherapy after Resection

    PubMed Central

    Herskind, Carsten; Wenz, Frederik; Giordano, Frank A.

    2017-01-01

    Brain metastases (BM) affect approximately a third of all cancer patients with systemic disease. Treatment options include surgery, whole-brain radiotherapy, or stereotactic radiosurgery (SRS) while chemotherapy has only limited activity. In cases where patients undergo resection before irradiation, intraoperative radiotherapy (IORT) to the tumor bed may be an alternative modality, which would eliminate the repopulation of residual tumor cells between surgery and postoperative radiotherapy. Accumulating evidence has shown that high single doses of ionizing radiation can be highly efficient in eliciting a broad spectrum of local, regional, and systemic tumor-directed immune reactions. Furthermore, immune checkpoint blockade (ICB) has proven effective in treating antigenic BM and, thus, combining IORT with ICB might be a promising approach. However, it is not known if a low number of residual tumor cells in the tumor bed after resection is sufficient to act as an immunizing event opening the gate for ICB therapies in the brain. Because immunological data on tumor bed irradiation after resection are lacking, a rationale for combining IORT with ICB must be based on mechanistic insight from experimental models and clinical studies on unresected tumors. The purpose of the present review is to examine the mechanisms by which large radiation doses as applied in SRS and IORT enhance antitumor immune activity. Clinical studies on IORT for brain tumors, and on combined treatment of SRS and ICB for unresected BM, are used to assess the safety, efficacy, and immunogenicity of IORT plus ICB and to suggest an optimal treatment sequence. PMID:28791250

  18. Immunotherapy Combined with Large Fractions of Radiotherapy: Stereotactic Radiosurgery for Brain Metastases-Implications for Intraoperative Radiotherapy after Resection.

    PubMed

    Herskind, Carsten; Wenz, Frederik; Giordano, Frank A

    2017-01-01

    Brain metastases (BM) affect approximately a third of all cancer patients with systemic disease. Treatment options include surgery, whole-brain radiotherapy, or stereotactic radiosurgery (SRS) while chemotherapy has only limited activity. In cases where patients undergo resection before irradiation, intraoperative radiotherapy (IORT) to the tumor bed may be an alternative modality, which would eliminate the repopulation of residual tumor cells between surgery and postoperative radiotherapy. Accumulating evidence has shown that high single doses of ionizing radiation can be highly efficient in eliciting a broad spectrum of local, regional, and systemic tumor-directed immune reactions. Furthermore, immune checkpoint blockade (ICB) has proven effective in treating antigenic BM and, thus, combining IORT with ICB might be a promising approach. However, it is not known if a low number of residual tumor cells in the tumor bed after resection is sufficient to act as an immunizing event opening the gate for ICB therapies in the brain. Because immunological data on tumor bed irradiation after resection are lacking, a rationale for combining IORT with ICB must be based on mechanistic insight from experimental models and clinical studies on unresected tumors. The purpose of the present review is to examine the mechanisms by which large radiation doses as applied in SRS and IORT enhance antitumor immune activity. Clinical studies on IORT for brain tumors, and on combined treatment of SRS and ICB for unresected BM, are used to assess the safety, efficacy, and immunogenicity of IORT plus ICB and to suggest an optimal treatment sequence.

  19. In vivo dosimetry with radiochromic films in low-voltage intraoperative radiotherapy of the breast.

    PubMed

    Avanzo, M; Rink, A; Dassie, A; Massarut, S; Roncadin, M; Borsatti, E; Capra, E

    2012-05-01

    EBT2 radiochromic films were studied and used for in vivo dosimetry in targeted intraoperative radiotherapy (TARGIT), a technique in which the Intrabeam system (Carl Zeiss, Oberkochen, Germany) is used to perform intraoperative partial breast irradiation with x-rays of 50 kV(p). The energy of the radiation emitted by the Intrabeam with the different spherical applicators, under 1 and 2 cm of solid water, and under the tungsten impregnated rubber used for shielding of the heart in TARGIT of the breast, was characterized with measurements of half-value layer (HVL). The stability of response of EBT2 was verified inside this range of energies. EBT2 films were calibrated using the red and green channels of the absorption spectrum in the 0-20 Gy dose range delivered by the Intrabeam x-rays. The dependence of film response on temperature during irradiation was measured. For in vivo dosimetry, pieces of radiochromic films wrapped in sterile envelopes were inserted after breast conserving surgery and before TARGIT into the excision cavity, on the skin and on the shielded pectoralis fascia for treatments of the left breast. HVLs of the Intrabeam in TARGIT of the breast correspond to effective energies of 20.7-36.3 keV. The response of EBT2 was constant inside this range of energies. We measured the dose to the target tissue and to organs at risk in 23 patients and obtained an average dose of 13.52 ± 1.21 Gy to the target tissue. Dose to the skin in close proximity to the applicator was 2.22 ± 0.97 Gy, 0.29 ± 0.17 Gy at 5-10 cm from the applicator, and 0.08 ± 0.07 Gy at more than 10 cm from the applicator. Dose to the pectoral muscle for left breast treatment was 0.57 ± 0.23 Gy. Our results show that EBT2 films are accurate at the beam energies, dose range, and irradiation temperature found in TARGIT and that in vivo dosimetry in TARGIT with EBT2 films wrapped in sterile envelopes is a feasible procedure. Measured dose to the organs at risk indicates

  20. In vivo dosimetry with radiochromic films in low-voltage intraoperative radiotherapy of the breast

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Avanzo, M.; Rink, A.; Dassie, A.

    Purpose: EBT2 radiochromic films were studied and used for in vivo dosimetry in targeted intraoperative radiotherapy (TARGIT), a technique in which the Intrabeam system (Carl Zeiss, Oberkochen, Germany) is used to perform intraoperative partial breast irradiation with x-rays of 50 kV{sub p}. Methods: The energy of the radiation emitted by the Intrabeam with the different spherical applicators, under 1 and 2 cm of solid water, and under the tungsten impregnated rubber used for shielding of the heart in TARGIT of the breast, was characterized with measurements of half-value layer (HVL). The stability of response of EBT2 was verified inside thismore » range of energies. EBT2 films were calibrated using the red and green channels of the absorption spectrum in the 0-20 Gy dose range delivered by the Intrabeam x-rays. The dependence of film response on temperature during irradiation was measured. For in vivo dosimetry, pieces of radiochromic films wrapped in sterile envelopes were inserted after breast conserving surgery and before TARGIT into the excision cavity, on the skin and on the shielded pectoralis fascia for treatments of the left breast. Results: HVLs of the Intrabeam in TARGIT of the breast correspond to effective energies of 20.7-36.3 keV. The response of EBT2 was constant inside this range of energies. We measured the dose to the target tissue and to organs at risk in 23 patients and obtained an average dose of 13.52 {+-} 1.21 Gy to the target tissue. Dose to the skin in close proximity to the applicator was 2.22 {+-} 0.97 Gy, 0.29 {+-} 0.17 Gy at 5-10 cm from the applicator, and 0.08 {+-} 0.07 Gy at more than 10 cm from the applicator. Dose to the pectoral muscle for left breast treatment was 0.57 {+-} 0.23 Gy. Conclusions: Our results show that EBT2 films are accurate at the beam energies, dose range, and irradiation temperature found in TARGIT and that in vivo dosimetry in TARGIT with EBT2 films wrapped in sterile envelopes is a feasible procedure

  1. SU-F-T-80: A Mobile Application for Intra-Operative Electron Radiotherapy Treatment Planning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, C; Harvard Medical School, Boston, MA; Crowley, E

    Purpose: Intraoperative electron radiotherapy (IORT) poses a unique set of challenges for treatment planning. Planning must be performed in a busy operating room environment over a short timeframe often with little advance knowledge of the treatment depth or applicator size. Furthermore, IORT accelerators can have a large number of possible applicators, requiring extensive databooks that must be searched for the appropriate dosimetric parameters. The goal of this work is to develop a software tool to assist in the planning process that is suited to the challenges faced in the IORT environment. Methods: We developed a mobile application using HTML5 andmore » Javascript that can be deployed to tablet devices suitable for use in the operating room. The user selects the desired treatment parameters cone diameter, bevel angle, and energy (a total of 141 datasets) and desired bolus. The application generates an interactive display that allows the user to dynamically select points on the depth-dose curve and to visualize the shape of the corresponding isodose contours. The user can indicate a prescription isodose line or depth. The software performs a monitor unit calculation and generates a PDF report. Results: We present our application, which is now used routinely in our IORT practice. It has been employed successfully in over 23 cases. The interactivity of the isodose distributions was found to be of particular use to physicians who are less-frequent IORT users, as well as for the education of residents and trainees. Conclusion: This software has served as a useful tool in IORT planning, and demonstrates the need for treatment planning tools that are designed for the specialized challenges encountered in IORT. This software is the subject of a license agreement with the IntraOp Medical Corporation. This software is the subject of a license agreement between Massachusetts General Hospital / Partners Healthcare and the IntraOp Medical Corporation. CLW is consulting on

  2. Favorable outcome of intraoperative radiotherapy to the primary site in patients with metastatic prostate cancer.

    PubMed

    Kanda, Toshihiro; Fukuda, Syohei; Fukui, Naotaka; Ohkubo, Yu; Kazumoto, Tomoko; Saito, Yoshihiro; Ishikawa, Ayataka; Kurosumi, Masafumi; Kageyama, Yukio; Fujii, Yasuhisa; Kihara, Kazunori

    2016-08-01

    The aim of this study was to determine whether local radiotherapy to the prostate by intraoperative radiotherapy (IORT) increases the overall and cancer-specific survival rates of patients with metastatic prostate cancer. Between 1993 and 2000, 102 patients with prostate cancer were treated with a combination of (a) IORT of the prostate (25 or 30 Gy per fraction); (b) external beam radiotherapy of the prostate (30 Gy in 10 fractions), starting approximately 1 week post-operatively; and (c) endocrine treatment. Of these, 16 patients had stage D1 disease (D1 IORT group), 32 had stage D2 disease without visceral metastasis (D2 IORT group), and 38 had stage D2 disease without visceral metastasis and did not receive local therapy (D2 control group). Overall and cancer-specific survival rates were compared. The 5- and 10-year cancer-specific survival rates were 75.9 and 52.7 %, respectively, in the (D1 + D2) IORT group and 45.8 and 33.5 %, respectively, in the D2 control group, with cancer-specific survival being significantly longer in the D2 IORT than in the D2 control group (P = 0.030). Univariate and multivariate reduced-rank regression analyses showed that extent of skeletal disease Grade 4 and non-regional lymph node metastasis were significantly prognostic of poorer cancer-specific survival (P < 0.001 each). Local radiotherapy to the prostate by IORT in patients with metastatic prostate cancer may contribute to better survival, especially in patients without extent of skeletal disease Grade 4 or non-regional lymph node metastasis.

  3. Gold coated lanthanide phosphate nanoparticles for targeted alpha generator radiotherapy.

    PubMed

    McLaughlin, Mark F; Woodward, Jonathan; Boll, Rose A; Wall, Jonathan S; Rondinone, Adam J; Kennel, Stephen J; Mirzadeh, Saed; Robertson, J David

    2013-01-01

    Targeted radiotherapies maximize cytotoxicty to cancer cells. In vivo α-generator targeted radiotherapies can deliver multiple α particles to a receptor site dramatically amplifying the radiation dose delivered to the target. The major challenge with α-generator radiotherapies is that traditional chelating moieties are unable to sequester the radioactive daughters in the bioconjugate which is critical to minimize toxicity to healthy, non-target tissue. The recoil energy of the (225)Ac daughters following α decay will sever any metal-ligand bond used to form the bioconjugate. This work demonstrates that an engineered multilayered nanoparticle-antibody conjugate can deliver multiple α radiations and contain the decay daughters of (225)Ac while targeting biologically relevant receptors in a female BALB/c mouse model. These multi-shell nanoparticles combine the radiation resistance of lanthanide phosphate to contain (225)Ac and its radioactive decay daughters, the magnetic properties of gadolinium phosphate for easy separation, and established gold chemistry for attachment of targeting moieties.

  4. Frequency of whole breast radiation therapy after intraoperative radiation therapy due to criteria identified by lumpectomy.

    PubMed

    Mellon, Eric A; Orman, Amber; Joya, Luis E; Montejo, Michael E; Laronga, Christine; Hoover, Susan J; Lee, M Catherine; Khakpour, Nazanin; Kubal, Pamela F; Diaz, Roberto

    For selected early breast cancers, intraoperative radiation therapy (IORT) at the time of lumpectomy can be an efficient alternative to fractionated whole breast radiation therapy (WBRT). However, some patients are later recommended WBRT after IORT due to surgical pathologic findings. To understand risk factor identification rates triggering WBRT recommendation, we analyzed adverse prognostic features based on multiple international criteria for suitability for accelerated partial breast irradiation. We performed a single-institution retrospective review of all 200 nonrecurrent invasive breast carcinomas that received IORT in 20 Gy to the tumor cavity using a 50 kV photon applicator between January 2011 and December 2015. IORT eligibility was based on the 2009 accelerated partial breast irradiation Consensus Statement from the American Society for Radiation Oncology (ASTRO). IORT was offered as the sole radiation modality to patients meeting 0-1 "cautionary" and no "unsuitable" criteria before lumpectomy. WBRT was recommended after IORT when 2+ cautionary and/or 1+ unsuitable criteria were met after accounting for resection pathology. We recalculated WBRT recommendation rates using initial and reresection margins for ASTRO consensus, Groupe Européen de Curiethérapie-European Society for Therapeutic Radiology and Oncology recommendations, and TARGeted Intraoperative radioTherapy vs. Postoperative Radiotherapy trial "prepathology" stratum protocol. Depending on the selection criteria chosen, rates of WBRT recommendation can vary from 4.5% to 33%. WBRT recommendation rates of 30-33% after lumpectomy and IORT are observed when the WBRT indication is a single ASTRO cautionary/unsuitable, Groupe Européen de Curiethérapie-European Society for Therapeutic Radiology and Oncology intermediate/high-risk criterion, or TARGeted Intraoperative radioTherapy vs. postoperative radiotherapy trial protocol recommendation. Alternatively, allowing for re-excision to clear margins

  5. Comparison of Local Recurrence Among Early Breast Cancer Patients Treated With Electron Intraoperative Radiotherapy vs Hypofractionated Photon Radiotherapy an Observational Study.

    PubMed

    Guenzi, Marina; Bonzano, Elisabetta; Corvò, Renzo; Merolla, Francesca; Pastorino, Alice; Cavagnetto, Francesca; Garelli, Stefania; Cutolo, Carlo Alberto; Friedman, Daniele; Belgioia, Liliana

    2018-01-01

    To evaluate local recurrence (LR) in women with early breast cancer (BC) who underwent intraoperative radiation therapy with electrons particles (IORT-E) or adjuvant hypofractionated external radiotherapy (HYPOFX). We retrospectively analyzed 470 patients with early BC treated at our center from September 2009 to December 2012. 235 women were treated with breast-conserving surgery and immediate IORT-E (21 Gy/1 fraction) while 235 patients underwent wide excision followed by hypofractionated whole-breast irradiation. Radiotherapy modality was chosen according to an individualized decision based on tumor features, stage, technical feasibility, age, and acceptance to be enrolled in the IORT-E group. After a median follow-up of 6 years, we observed 8 (3.4%) and 1 (0.42%) LR in the IORT-E and in the HYPOFX group ( p  = 0.02), respectively. The two groups differed in the prevalence of clinical characteristics ( p  < 0.05): age, tumor size, surgical margins, receptors, ki67, and histology. 4 and 1 woman in the IORT-E and HYPOFX group died of BC, respectively ( p  = 0.167). OS and DFS hazard ratio [HR] were 2.14 (95% IC, 1.10-4.15) and 2.09 (95% IC, 1.17-3.73), respectively. Our comparison showed that IORT-E and HYPOFX are two effective radiotherapy modalities after conservative surgery in early BC. However, at 6 years a significant higher rate of LR occurred in patients submitted to IORT-E with respect to HYPOFX. This finding may be correlated to some subsets of patients who, depending on the biological characteristics of the BC, may be less suitable to IORT-E.

  6. Intraoperative irradiation: precision medicine for quality cancer control promotion.

    PubMed

    Calvo, Felipe A

    2017-02-02

    Intraoperative irradiation was implemented 4 decades ago, pioneering the efforts to improve precision in local cancer therapy by combining real-time surgical exploration/resection with high single dose radiotherapy (Gunderson et al., Intraoperative irradiation: techniques and results, 2011). Clinical and technical developments have led to very precise radiation dose deposit. The ability to deliver a very precise dose of radiation is an essential element of contemporary multidisciplinary individualized oncology.This issue of Radiation Oncology contains a collection of expert review articles and updates with relevant data regarding intraoperative radiotherapy. Technology, physics, biology of single dose and clinical results in a variety of cancer sites and histologies are described and analyzed. The state of the art for advanced cancer care through medical innovation opens a significant opportunity for individualize cancer management across a broad spectrum of clinical practice. The advantage for tailoring diagnostic and treatment decisions in an individualized fashion will translate into precise medical treatment.

  7. Basic immunology of antibody targeted radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wong, Jeffrey Y.C.

    2006-10-01

    Antibody targeted radiotherapy brings an important new treatment modality to Radiation oncology clinic. Radiation dose to tumor and normal tissues are determined by a complex interplay of antibody, antigen, tumor, radionuclide, and host-related factors. A basic understanding of these immunologic and physiologic factors is important to optimally utilize this therapy in the clinic. Preclinical and clinical studies need to be continued to broaden our understanding and to develop new strategies to further improve the efficacy of this promising form of targeted therapy.

  8. First description of MR mammographic findings in the tumor bed after intraoperative radiotherapy (IORT) of breast cancer.

    PubMed

    Wasser, Klaus; Schnitzer, Andreas; Engel, Dorothee; Krammer, Julia; Wenz, Frederik; Kraus-Tiefenbacher, Uta; Suetterlin, Marc; Schoenberg, Stefan O; Weisser, Gerald

    2012-01-01

    The aim was to investigate changes in the tumor bed on magnetic resonance mammography (MRM) after intraoperative radiotherapy (IORT) and whether they would limit the diagnostic value of posttherapeutic MRM. We retrospectively investigated 36 patients undergoing MRM after IORT (median interval 2.8 years, range 0.4-7.1). Wound cavities with fat necrosis were common after IORT (81%). They were associated with persisting contrast enhancement, i.e., enhancement was mostly seen irrespective of the posttherapeutic interval. It normally presented as rim enhancement and did not cause any diagnostic uncertainty if viewed together with other tissue characteristics. We do not expect a limited diagnostic value of MRM after IORT. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Evaluation of targeting errors in ultrasound-assisted radiotherapy

    PubMed Central

    Wang, Michael; Rohling, Robert; Duzenli, Cheryl; Clark, Brenda; Archip, Neculai

    2014-01-01

    A method for validating the start-to-end accuracy of a 3D ultrasound-based patient positioning system for radiotherapy is described. A radiosensitive polymer gel is used to record the actual dose delivered to a rigid phantom after being positioned using 3D ultrasound guidance. Comparison of the delivered dose with the treatment plan allows accuracy of the entire radiotherapy treatment process, from simulation to 3D ultrasound guidance, and finally delivery of radiation, to be evaluated. The 3D ultrasound patient positioning system has a number of features for achieving high accuracy and reducing operator dependence. These include using tracked 3D ultrasound scans of the target anatomy acquired using a dedicated 3D ultrasound probe during both the simulation and treatment sessions, automatic 3D ultrasound-to-ultrasound registration, and use of infra-red LED (IRED) markers of the optical position sensing system for registering simulation CT to ultrasound data. The mean target localization accuracy of this system was 2.5mm for four target locations inside the phantom, compared to 1.6mm obtained using the conventional patient positioning method of laser alignment. Since the phantom is rigid, this represents the best possible set-up accuracy of the system. Thus, these results suggest that 3D ultrasound-based target localization is practically feasible and potentially capable of increasing the accuracy of patient positioning for radiotherapy in sites where day-to-day organ shifts are greater than 1mm in magnitude. PMID:18723271

  10. Intraoperative magnetic resonance imaging during surgery for pituitary adenomas: pros and cons.

    PubMed

    Buchfelder, Michael; Schlaffer, Sven-Martin

    2012-12-01

    Surgery for pituitary adenomas still remains a mainstay in their treatment, despite all advances in sophisticated medical treatments and radiotherapy. Total tumor excision is often attempted, but there are limitations in the intraoperative assessment of the radicalism of tumor resection by the neurosurgeon. Standard postoperative imaging is usually performed with a few months delay from the surgical intervention. The purpose of this report is to review briefly the facilities and kinds of intraoperative magnetic resonance imaging for all physician and surgeons involved in the management of pituitary adenomas on the basis of current literature. To date, there are several low- and high-field magnetic resonance imaging systems available for intraoperative use and depiction of the extent of tumor removal during surgery. Recovery of vision and the morphological result of surgery can be largely predicted from the intraoperative images. A variety of studies document that depiction of residual tumor allows targeted attack of the remnant and extent the resection. Intraoperative magnetic resonance imaging offers an immediate feedback to the surgeon and is a perfect quality control for pituitary surgery. It is also used as a basis of datasets for intraoperative navigation which is particularly useful in any kind of anatomical variations and repeat operations in which primary surgery has distorted the normal anatomy. However, setting up the technology is expensive and some systems even require extensive remodeling of the operation theatre. Intraoperative imaging prolongs the operation, but may also depict evolving problems, such as hematomas in the tumor cavity. There are several artifacts in intraoperative MR images possible that must be considered. The procedures are not associated with an increased complication rate.

  11. The role of PET in target localization for radiotherapy treatment planning.

    PubMed

    Rembielak, Agata; Price, Pat

    2008-02-01

    Positron emission tomography (PET) is currently accepted as an important tool in oncology, mostly for diagnosis, staging and restaging purposes. It provides a new type of information in radiotherapy, functional rather than anatomical. PET imaging can also be used for target volume definition in radiotherapy treatment planning. The need for very precise target volume delineation has arisen with the increasing use of sophisticated three-dimensional conformal radiotherapy techniques and intensity modulated radiation therapy. It is expected that better delineation of the target volume may lead to a significant reduction in the irradiated volume, thus lowering the risk of treatment complications (smaller safety margins). Better tumour visualisation also allows a higher dose of radiation to be applied to the tumour, which may lead to better tumour control. The aim of this article is to review the possible use of PET imaging in the radiotherapy of various cancers. We focus mainly on non-small cell lung cancer, lymphoma and oesophageal cancer, but also include current opinion on the use of PET-based planning in other tumours including brain, uterine cervix, rectum and prostate.

  12. Postoperative complications following intraoperative radiotherapy in abdominopelvic malignancy: A single institution analysis of 113 consecutive patients.

    PubMed

    Abdelfatah, Eihab; Page, Andrew; Sacks, Justin; Pierorazio, Phillip; Bivalacqua, Trinity; Efron, Jonathan; Terezakis, Stephanie; Gearhart, Susan; Fang, Sandy; Safar, Bashar; Pawlik, Timothy M; Armour, Elwood; Hacker-Prietz, Amy; Herman, Joseph; Ahuja, Nita

    2017-06-01

    Intraoperative radiotherapy (IORT) has advantages over external beam radiation therapy (EBRT). Few studies have described side effects associated with its addition. We evaluated our institution's experience with abdominopelvic IORT to assess safety by postoperative complication rates. Prospectively collected IRB-approved database of all patients receiving abdominopelvic IORT (via high dose rate brachytherapy) at Johns Hopkins Hospital between November 2006 and May 2014 was reviewed. Patients were discussed in multidisciplinary conferences. Those selected for IORT were patients for whom curative intent resection was planned for which IORT could improve margin-negative resection and optimize locoregional control. Perioperative complications were classified via Clavien-Dindo scale for postoperative surgical complications. A total of 113 patients were evaluated. Most common diagnosis was sarcoma (50/113, 44%) followed by colorectal cancer (45/113, 40%), most of which were recurrent (84%). There were no perioperative deaths. A total of 57% of patients experienced a complication Grade II or higher: 24% (27/113) Grade II; 27% (30/113) Grade III; 7% (8/113) Grade IV. Wound complications were most common (38%), then gastrointestinal (25%). No radiotherapy variables were significantly associated with complications on uni/multi-variate analysis. Our institution's experience with IORT demonstrated historically expected postoperative complication rates. IORT is safe, with acceptable perioperative morbidity. © 2017 Wiley Periodicals, Inc.

  13. Targeted delivery of cancer-specific multimodal contrast agents for intraoperative detection of tumor boundaries and therapeutic margins

    NASA Astrophysics Data System (ADS)

    Xu, Ronald X.; Xu, Jeff S.; Huang, Jiwei; Tweedle, Michael F.; Schmidt, Carl; Povoski, Stephen P.; Martin, Edward W.

    2010-02-01

    Background: Accurate assessment of tumor boundaries and intraoperative detection of therapeutic margins are important oncologic principles for minimal recurrence rates and improved long-term outcomes. However, many existing cancer imaging tools are based on preoperative image acquisition and do not provide real-time intraoperative information that supports critical decision-making in the operating room. Method: Poly lactic-co-glycolic acid (PLGA) microbubbles (MBs) and nanobubbles (NBs) were synthesized by a modified double emulsion method. The MB and NB surfaces were conjugated with CC49 antibody to target TAG-72 antigen, a human glycoprotein complex expressed in many epithelial-derived cancers. Multiple imaging agents were encapsulated in MBs and NBs for multimodal imaging. Both one-step and multi-step cancer targeting strategies were explored. Active MBs/NBs were also fabricated for therapeutic margin assessment in cancer ablation therapies. Results: The multimodal contrast agents and the cancer-targeting strategies were tested on tissue simulating phantoms, LS174 colon cancer cell cultures, and cancer xenograft nude mice. Concurrent multimodal imaging was demonstrated using fluorescence and ultrasound imaging modalities. Technical feasibility of using active MBs and portable imaging tools such as ultrasound for intraoperative therapeutic margin assessment was demonstrated in a biological tissue model. Conclusion: The cancer-specific multimodal contrast agents described in this paper have the potential for intraoperative detection of tumor boundaries and therapeutic margins.

  14. An experimental attenuation plate to improve the dose distribution in intraoperative electron beam radiotherapy for breast cancer.

    PubMed

    Oshima, T; Aoyama, Y; Shimozato, T; Sawaki, M; Imai, T; Ito, Y; Obata, Y; Tabushi, K

    2009-06-07

    Intraoperative electron beam radiotherapy (IOERT) is a technique in which a single-fraction high dose is intraoperatively delivered to subclinical tumour cells using an electron beam after breast-conserving surgery. In IOERT, an attenuation plate consisting of a pair of metal disks is commonly used to protect the normal tissues posterior to the breast. However, the dose in front of the plate is affected by backscatter, resulting in an unpredictable delivered dose to the tumour cells. In this study, an experimental attenuation plate, termed a shielding plate, was designed using Monte Carlo simulation, which significantly diminished the electron beam without introducing any backscatter radiation. The plate's performance was verified by measurements. It was made of two layers, a first layer (source side) of polymethyl methacrylate (PMMA) and a second layer of copper, which was selected from among other metals (aluminium, copper and lead) after testing for shielding capability and the range and magnitude of backscatter. The optimal thicknesses of the PMMA (0.71 cm) and copper (0.3 cm) layers were determined by changing their thicknesses during simulations. On the basis of these results, a shielding plate was prototyped and depth doses with and without the plate were measured by radiophotoluminescence glass dosimeters using a conventional stationary linear accelerator and a mobile linear accelerator dedicated for IOERT. The trial shielding plate functioned as intended, indicating its applicability in clinical practice.

  15. Intraoperative radiotherapy given as a boost for early breast cancer: Long-term clinical and cosmetic results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lemanski, Claire; Azria, David; Thezenas, Simon

    2006-04-01

    Purpose: The standard radiotherapy (RT) of breast cancer consists of 50 Gy external beam RT (EBRT) to the whole breast followed by an electron boost of 10-16 Gy to the tumor bed, but this has several cosmetic disadvantages. Intraoperative radiotherapy (IORT) could be an alternative to overcome these. Methods and Materials: We evaluated 50 women with early breast cancer operated on in a dedicated IORT facility. Median dose of 10 Gy was delivered using 9-MeV electron beams. All patients received postoperative EBRT (50 Gy in 2 Gy fractions). Late toxicity and cosmetic results were assessed independently by two physicians accordingmore » to the Common Terminology Criteria for Adverse Event v3.0 grading system and the European Organization for Research and Treatment of Cancer questionnaires. Results: After a median follow-up of 9.1 years (range, 5-15 years), two local recurrences were observed within the primary tumor bed. At the time of analysis, 45 patients are alive with (n = 1) or without disease. Among the 42 disease-free remaining patients, 6 experienced Grade 2 late subcutaneous fibrosis within the boost area. Overall, the scores indicated a very good quality of life and cosmesis was good to excellent in the evaluated patients. Conclusion: Our results confirm that IORT given as a boost after breast-conserving surgery is a reliable alternative to conventional postoperative fractionated boost radiation.« less

  16. Potential of activatable FAP-targeting immunoliposomes in intraoperative imaging of spontaneous metastases.

    PubMed

    Tansi, Felista L; Rüger, Ronny; Böhm, Claudia; Kontermann, Roland E; Teichgraeber, Ulf K; Fahr, Alfred; Hilger, Ingrid

    2016-05-01

    Despite intensive research and medical advances met, metastatic disease remains the most common cause of death in cancer patients. This results from late diagnosis, poor therapeutic response and undetected micrometastases and tumor margins during surgery. One approach to overcome these challenges involves fluorescence imaging, which exploits the properties of fluorescent probes for diagnostic detection of molecular structures at the onset of transformation and for intraoperative detection of metastases and tumor margins in real time. Considering these benefits, many contrast agents suitable for fluorescence imaging have been reported. However, most reports only demonstrate the detection of primary tumors and not the detection of metastases or their application in models of image-guided surgery. In this work, we demonstrate the influence of fibroblast activation protein (FAP) on the metastatic potential of fibrosarcoma cells and elucidate the efficacy of activatable FAP-targeting immunoliposomes (FAP-IL) for image-guided detection of the spontaneous metastases in mice models. Furthermore, we characterized the biodistribution and cellular localization of the liposomal fluorescent components in mice organs and traced their excretion over time in urine and feces. Taken together, activatable FAP-IL enhances intraoperative imaging of metastases. Their high accumulation in metastases, subsequent localization in the bile canaliculi and liver kupffer cells and suitable excretion in feces substantiates their potency as contrast agents for intraoperative imaging. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. New Methods for Targeted Alpha Radiotherapy

    NASA Astrophysics Data System (ADS)

    Robertson, J. David

    2014-03-01

    Targeted radiotherapies based on alpha emitters are a promising alternative to beta emitting radionuclides. Because of their much shorter range, targeted α-radiotherapy (TAT) agents have great potential for application to small, disseminated tumors and micro metastases and treatment of hematological malignancies consisting of individual, circulating neoplastic cells. A promising approach to TAT is the use of the in vivo α-generator radionuclides 223 = 11.4 d) and 225Ac 1/2 = 10.0 d). In addition to their longer half-lives, these two isotopes have the potential of dramatically increasing the therapeutic efficacy of TAT as they each emit four α particles in their decay chain. This principle has recently been exploited in the development of Xofigo®, the first TAT agent approved for clinical use by the U.S. FDA. Xofigo, formulated as 223RaCl2, is used for treatment of metastatic bone cancer in men with castration-resistant prostate cancer. TAT with 223Ra works, however, only in the case of bone cancer because radium, as a chemical analogue of calcium, efficiently targets bone. In order to bring the benefits of TAT with 223Ra or 225Ac to other tumor types, a new delivery method must be devised. Retaining the in vivo α generator radionuclides at the target site through the decay process is one of the major challenges associated with the development of TAT. Because the recoil energy of the daughter radionuclides from the α-emission is ~ 100 keV - a value which is four orders of magnitude greater than the energy of a covalent bond - the daughters will not remain bound to the bioconjugate at the targeting site. Various approaches have been attempted to achieve retention of the α-generator daughter radionuclides at the target site, including incorporation of the in vivo generator into liposomes and fullerenes. Unfortunately, to date single wall liposomes and fullerenes are able to retain less than 10% of the daughter radionuclides. We have recently demonstrated that a

  18. Long-Term Survivors Using Intraoperative Radiotherapy for Recurrent Gynecologic Malignancies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tran, Phuoc T.; Su Zheng; Hara, Wendy

    2007-10-01

    Purpose: To analyze the outcomes of therapy and identify prognostic factors for patients treated with surgery followed by intraoperative radiotherapy (IORT) for gynecologic malignancies at a single institution. Methods and Materials: We performed a retrospective review of 36 consecutive patients treated with IORT to 44 sites with mean follow-up of 50 months. The primary site was the cervix in 47%, endometrium in 31%, vulva in 14%, vagina in 6%, and fallopian tubes in 3%. Previous RT had failed in 72% of patients, and 89% had recurrent disease. Of 38 IORT sessions, 84% included maximal cytoreductive surgery, including 18% exenterations. Themore » mean age was 52 years (range, 30-74), mean tumor size was 5 cm (range, 0.5-12), previous disease-free interval was 32 months (range, 0-177), and mean IORT dose was 1,152 cGy (range, 600-1,750). RT and systemic therapy after IORT were given to 53% and 24% of the cohort, respectively. The outcomes measured were locoregional control (LRC), distant metastasis-free survival (DMFS), disease-specific survival (DSS), and treatment-related complications. Results: The Kaplan-Meier 5-year LRC, DMFS, and DSS probability for the whole group was 44%, 51%, and 47%, respectively. For cervical cancer patients, the Kaplan-Meier 5-year LRC, DMFS, and DSS estimate was 45%, 60%, and 46%, respectively. The prognostic factors found on multivariate analysis (p {<=} 0.05) were the disease-free interval for LRC, tumor size for DMFS, and cervical primary, previous surgery, and locoregional relapse for DSS. Our cohort had 10 Grade 3-4 complications associated with treatment (surgery and IORT) and a Kaplan-Meier 5-year Grade 3-4 complication-free survival rate of 72%. Conclusions: Survival for pelvic recurrence of gynecologic cancer is poor (range, 0-25%). IORT after surgery seems to confer long-term local control in carefully selected patients.« less

  19. Targeted Radiotherapy of Estrogen Receptor Positive Tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Raghavan Rajagopalan

    The overall objectives of the proposal were to develop estrogen receptor (ER) binding small molecule radiopharmaceuticals for targeted radiotherapy of ER positive (ER+) tumors. In particular, this proposal focused on embedding a {sup 186,188}Re or a {sup 32}P radionuclide into an estrogen steroidal framework by isosteric substitution such that the resulting structure is topologically similar to the estrogen (estrogen mimic). The estrogen mimic molecules expected to bind to the ER and exhibit biodistribution akin to that of native estrogen due to structural mimicry. It is anticipated that the {sup 186,188}Re- or a {sup 32}P-containing estrogen mimics will be useful formore » targeted molecular radiotherapy of ER+ tumors. It is well established that the in vivo target tissue uptake of estrogen like steroidal molecules is related to the binding of the steroids to sex hormone binding globulin (SHBG). SHBG is important in the uptake of estrogens and testosterone in target tissues by SHBG receptors on the cell surface. However, hitherto the design of estrogen like small molecule radiopharmaceuticals was focused on optimizing ER binding characteristics without emphasis on SHBG binding properties. Consequently, even the molecules with good ER affinity in vitro, performed poorly in biodistribution studies. Based on molecular modeling studies the proposal focused on developing estrogen mimics 1-3 which were topologically similar to native estrogens, and form hydrogen bonds in ER and SHBG in the same manner as those of native estrogens. To this end the technical objectives of the proposal focused on synthesizing the rhenium-estrone and estradiol mimics 1 and 2 respectively, and phosphorous estradiol mimic 3 and to assess their stability and in vitro binding characteristics to ER and SHBG.« less

  20. Cosmetic Outcomes for Accelerated Partial Breast Irradiation Before Surgical Excision of Early-Stage Breast Cancer Using Single-Dose Intraoperative Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kimple, Randall J.; Klauber-DeMore, Nancy; Lineberger Comprehensive Cancer Center, University of North Carolina at Chapel Hill, Chapel Hill, NC

    2011-02-01

    Purpose: Determine cosmetic outcome and toxicity profile of intraoperative radiation delivered before tumor excision for patients with early-stage breast cancer. Methods and Materials: Patients age 48 or older with ultrasound-visible invasive ductal cancers <3 cm and clinically negative lymph nodes were eligible for treatment on this institutional review board-approved Phase II clinical trial. Treatment planning ultrasound was used to select an electron energy and cone size sufficient to cover the tumor plus a 1.5- to 2.0-cm circumferential margin laterally and a 1-cm-deep margin with the 90% isodose line. The dose was prescribed to a nominal 15 Gy and delivered usingmore » a Mobetron electron irradiator before tumor excision by segmental mastectomy. Physician- and patient-assessed cosmetic outcome and patient satisfaction were determined by questionnaire. Results: From March 2003 to July 2007, 71 patients were treated with intraoperative radiation therapy. Of those, 56 patients were evaluable, with a median follow-up of 3.1 years (minimum 1 year). Physician and patient assessment of cosmesis was 'good or excellent' (Radiation Therapy Oncology Group cosmesis scale) in 45/56 (80%) and 32/42 (76%) of all patients, respectively. Eleven patients who received additional whole breast radiation had similar rates of good or excellent cosmesis: 40/48 (83%) and 29/36 (81%), respectively). Grade 1 or 2 acute toxicities were seen in 4/71 (6%) patients. No Grade 3 or 4 toxicities or serious adverse events have been seen. Conclusion: Intraoperative radiotherapy delivered to an in situ tumor is feasible with acceptable acute tolerance. Patient and physician assessment of the cosmetic outcome is good to excellent.« less

  1. Locoregional control after intensity-modulated radiotherapy for nasopharyngeal carcinoma with an anatomy-based target definition.

    PubMed

    Kawashima, Mitsuhiko; Ariji, Takaki; Kameoka, Satoru; Ueda, Takashi; Kohno, Ryosuke; Nishio, Teiji; Arahira, Satoko; Motegi, Atsushi; Zenda, Sadamoto; Akimoto, Tetsuo; Tahara, Makoto; Hayashi, Ryuichi

    2013-12-01

    The objective of the study was to evaluate locoregional control after intensity-modulated radiotherapy for nasopharyngeal cancer using a target definition along with anatomical boundaries. Forty patients with biopsy-proven squamous cell or non-keratinizing carcinoma of the nasopharynx who underwent intensity-modulated radiotherapy between April 2006 and November 2009 were reviewed. There were 10 females and 30 males with a median age of 48 years (range, 17-74 years). More than half of the patients had T3/4 (n = 21) and/or N2/3 (n = 24) disease. Intensity-modulated radiotherapy was administered as 70 Gy/33 fractions with or without concomitant chemotherapy. The clinical target volume was contoured along with muscular fascia or periosteum, and the prescribed radiotherapy dose was determined for each anatomical compartment and lymph node level in the head and neck. One local recurrence was observed at Meckel's cave on the periphery of the high-risk clinical target volume receiving a total dose of <63 Gy. Otherwise, six locoregional failures were observed within irradiated volume receiving 70 Gy. Local and nodal control rates at 3 years were 91 and 89%, respectively. Adverse events were acceptable, and 25 (81%) of 31 patients who were alive without recurrence at 2 years had xerostomia of ≤Grade 1. The overall survival rate at 3 years was 87%. Target definition along with anatomically defined boundaries was feasible without compromise of the therapeutic ratio. It is worth testing this method further to minimize the unnecessary irradiated volume and to standardize the target definition in intensity-modulated radiotherapy for nasopharyngeal cancer.

  2. Applications of 211At and 223Ra in Targeted Alpha-Particle Radiotherapy

    PubMed Central

    Vaidyanathan, Ganesan; Zalutsky, Michael R.

    2012-01-01

    Targeted radiotherapy using agents tagged with α-emitting radionuclides is gaining traction with several clinical trials already undertaken or ongoing, and others in the advanced planning stage. The most commonly used α-emitting radionuclides are 213Bi, 211At, 223Ra and 225Ac. While each one of these has pros and cons, it can be argued that 211At probably is the most versatile based on its half life, decay scheme and chemistry. On the other hand, for targeting bone metastases, 223Ra is the ideal radionuclide because simple cationic radium can be used for this purpose. In this review, we will discuss the recent developments taken place in the application of 211At-labeled radiopharmaceuticals and give an overview of the current status of 223Ra for targeted α-particle radiotherapy. PMID:22202151

  3. Intraoperative radiotherapy for patients with carcinoma of the pancreas. The Howard University Hospital experience, 1978-1986.

    PubMed

    Tuckson, W B; Goldson, A L; Ashayeri, E; Halyard-Richardson, M; DeWitty, R L; Leffall, L D

    1988-06-01

    During the period from 1978 to 1986, 106 patients were diagnosed with carcinoma of the pancreas; 30 of these patients were excluded from this study. Of the remaining 76 patients, 40 did not receive intraoperative radiotherapy (IORT) and were used as the nonrandomized control group for the 36 patients who did receive IORT after histologic confirmation of carcinoma of the pancreas. The records of 35 patients were available for review. The group receiving IORT ranged in ages from 43 to 89 years (20 males and 15 females). Seventeen patients had distant metastatic disease. The primary was located in the head of the pancreas in 32 and the body in three. No patient in this group had a curative resection. All patients were treated by a combination of biliary and gastric bypass prior to or concurrent with IORT. IORT was begun only after obtaining a histologic diagnosis and prior to the completion of any anastomosis. Necrotizing pancreatitis occurred in the treated group. There was no statistically significant difference in the survival of the nonrandomized control and treated groups.

  4. High- and low-dose-rate intraoperative radiotherapy for thoracic malignancies resected with close or positive margins.

    PubMed

    Fleming, Christopher; Rimner, Andreas; Cohen, Gil'ad N; Woo, Kaitlin M; Zhang, Zhigang; Rosenzweig, Kenneth E; Alektiar, Kaled M; Zelefsky, Michael J; Bains, Manjit S; Wu, Abraham J

    2016-01-01

    Local recurrence is a significant problem after surgical resection of thoracic tumors. As intraoperative radiotherapy (IORT) can deliver radiation directly to the threatened margin, we have used this therapy in an attempt to reduce local recurrence, using high-dose-rate (HDR) as well as low-dose-rate (LDR) techniques. We performed a retrospective review of patients undergoing LDR ((125)I) mesh placement or HDR ((192)Ir) afterloading therapy during lung tumor resection between 2001 and 2013 at our institution. Competing risks methods were used to estimate the cumulative incidence of local failure. We also assessed possible predictive factors of local failure. Fifty-nine procedures (41 LDR and 18 HDR) were performed on 58 patients. Median follow-up was 55.1 months. Cumulative incidence of local failure at 1, 2, and 3 years was 28.5%, 34.2%, and 34.2%, respectively. Median overall survival was 39.9 months. There was no significant difference in local failure according to margin status, HDR vs. LDR, use of adjuvant external beam radiotherapy, or metastatic vs. primary tumor. Two patients (3.4%) experienced Grade 3+ toxicities likely related to brachytherapy. Additionally, 7 patients experienced Grade 3+ postsurgical complications unlikely related to brachytherapy. IORT is associated with good local control after resection of thoracic tumors otherwise at very high risk for local recurrence. There is a low incidence of severe toxicity attributable to brachytherapy. HDR-IORT appears to have equivalent outcomes to LDR-IORT. HDR or LDR-IORT can, therefore, be considered in situations where the oncologic completeness of thoracic tumor resection is in doubt. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  5. Combination of external-beam radiotherapy with intraoperative electron-beam therapy is effective in incompletely resected pediatric malignancies.

    PubMed

    Oertel, Susanne; Niethammer, Andreas G; Krempien, Robert; Roeder, Falk; Eble, Michael J; Baer, Claudia; Huber, Peter E; Kulozik, Andreas; Waag, Karl-Ludwig; Treiber, Martina; Debus, Juergen

    2006-01-01

    Intraoperative electron-beam radiotherapy (IOERT) has been applied for local dose escalation in over 1,400 patients in Heidelberg since 1991. Among these were 30 children, in 18 of whom IOERT was employed in radiation treatment with external-beam radiotherapy (EBRT) on account of incomplete resection. We address the question whether IOERT is able to compensate for microscopic or macroscopic tumor residue if employed in the overall radiation regimen. The data of the aforementioned 18 children were analyzed with regard to local recurrence, overall survival, and complication rates. All children suffered from either sarcomas or neuroblastomas. In all children, IOERT was employed for local dose escalation after or before EBRT. After a median follow-up of 60.5 months, 15 of the treated children are alive. One local failure has been observed. Six children show clinically significant late morbidity, including the loss of a treated limb (Radiation Therapy Oncology Group Grade 4 [RTOG 4]), a severe nerve lesion (RTOG 3), an orthopedic complication (RTOG 2), a ureteral stenosis (not clinically significant), and a kidney hypotrophy (not clinically significant). In 1 child a fracture due to radionecrosis (RTOG 4) was diagnosed; however, in the follow-up, local tumor relapse was diagnosed as another possible reason for the fracture. Regarding the low incidence of local failure, IOERT seems to be able to compensate incomplete tumor resection in childhood sarcoma and neuroblastoma patients. The incidence of late morbidity is low enough to justify the employment of IOERT as part of the radiation treatment regimen for pediatric patients.

  6. The impact of the use of intraoperative radiotherapy on costs, travel time and distance for women with breast cancer in the Mexico City Metropolitan Area.

    PubMed

    Bargallo-Rocha, Juan Enrique; Soto-Perez-de-Celis, Enrique; Picó-Guzmán, Francisco Javier; Quintero-Rodríguez, Carlos Eduardo; Almog, David; Santiago-Concha, Gabriel; Flores-Balcazar, Christian Haydee; Corona, Jaime; Vazquez-Romo, Rafael; Villarreal-Garza, Cynthia; Mohar, Alejandro

    2017-11-01

    The low availability and poor access to external beam radiotherapy (EBRT) in developing countries makes it hard for women with breast cancer to receive breast conservation. We studied the effect of providing intraoperative radiotherapy (IORT) on the travel time, distance, and costs of in the Mexico City Metropolitan Area (MCMA). Sixty-nine patients treated between January 2013 and September 2014 were analyzed. Travel distance and transit time was calculated using Google Maps. The time and distance patients living in the MCMA treated with IORT would have spent if they had received EBRT was calculated. Cost analysis for each modality was performed. 71% (n = 49) lived in the MCMA. Sixteen (33%) received additional EBRT and 33 (66%) received IORT only. Mean driving distance and transit time of those 33 women was 132.6 km (SD 25.7) and 66 min (SD 32.9). Patients from the MCMA receiving IORT alone avoided 990 visits, 43 700 km and 65 400 min in transit. IORT led to a 12% reduction in costs per patient. By reducing costs and time needed for patients to receive radiotherapy, IORT could potentially enhance access to breast conservation in resource-limited developing countries. © 2017 Wiley Periodicals, Inc.

  7. SU-E-T-756: Tissue Inhomogeneity Corrections in Intra-Operative Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sethi, A; Chinsky, B; Gros, S

    Purpose: Investigate the impact of tissue inhomogeneities on dose distributions produced by low-energy X-rays in intra-operative radiotherapy (IORT). Methods: A 50-kV INTRABEAM X-ray device with superficial (Flat and Surface) applicators was commissioned at our institution. For each applicator, percent depth-dose (PDD), dose-profiles (DP) and output factors (OF) were obtained. Calibrated GaFchromic (EBT3) films were used to measure dose distributions in solid water phantom at various depths (2, 5, 10, and 15 mm). All recommended precautions for film-handling, film-exposure and scanning were observed. The effects of tissue inhomogeneities on dose distributions were examined by placing air-cavities and bone and tissue equivalentmore » materials of different density (ρ), atomic number (Z), and thickness (t = 0–4mm) between applicator and film detector. All inhomogeneities were modeled as a cylindrical cavity (diameter 25 mm). Treatment times were calculated to deliver 1Gy dose at 5mm depth. Film results were verified by repeat measurements with a thin-window parallel plate ion-chamber (PTW 34013A) in a water tank. Results: For a Flat-4cm applicator, the measured dose rate at 5mm depth in solid water was 0.35 Gy/min. Introduction of a cylindrical air-cavity resulted in an increased dose past the inhomogeneity. Compared to tissue equivalent medium, dose enhancement due to 1mm, 2mm, 3mm and 4mm air cavities was 10%, 16%, 24%, and 35% respectively. X-ray attenuation by 2mm thick cortical bone resulted in a significantly large (58%) dose decrease. Conclusion: IORT dose calculations assume homogeneous tissue equivalent medium. However, soft X-rays are easily affected by non-tissue equivalent materials. The results of this study may be used to estimate and correct IORT dose delivered in the presence of tissue inhomogeneities.« less

  8. Defining Action Levels for In Vivo Dosimetry in Intraoperative Electron Radiotherapy.

    PubMed

    López-Tarjuelo, Juan; Morillo-Macías, Virginia; Bouché-Babiloni, Ana; Ferrer-Albiach, Carlos; Santos-Serra, Agustín

    2016-06-01

    In vivo dosimetry is recommended in intraoperative electron radiotherapy (IOERT). To perform real-time treatment monitoring, action levels (ALs) have to be calculated. Empirical approaches based on observation of samples have been reported previously, however, our aim is to present a predictive model for calculating ALs and to verify their validity with our experimental data. We considered the range of absorbed doses delivered to our detector by means of the percentage depth dose for the electron beams used. Then, we calculated the absorbed dose histograms and convoluted them with detector responses to obtain probability density functions in order to find ALs as certain probability levels. Our in vivo dosimeters were reinforced TN-502RDM-H mobile metal-oxide-semiconductor field-effect transistors (MOSFETs). Our experimental data came from 30 measurements carried out in patients undergoing IOERT for rectal, breast, sarcoma, and pancreas cancers, among others. The prescribed dose to the tumor bed was 90%, and the maximum absorbed dose was 100%. The theoretical mean absorbed dose was 90.3% and the measured mean was 93.9%. Associated confidence intervals at P = .05 were 89.2% and 91.4% and 91.6% and 96.4%, respectively. With regard to individual comparisons between the model and the experiment, 37% of MOSFET measurements lay outside particular ranges defined by the derived ALs. Calculated confidence intervals at P = .05 ranged from 8.6% to 14.7%. The model can describe global results successfully but cannot match all the experimental data reported. In terms of accuracy, this suggests an eventual underestimation of tumor bed bleeding or detector alignment. In terms of precision, it will be necessary to reduce positioning uncertainties for a wide set of location and treatment postures, and more precise detectors will be required. Planning and imaging tools currently under development will play a fundamental role. © The Author(s) 2015.

  9. Real-time intraoperative evaluation of implant quality and dose correction during prostate brachytherapy consistently improves target coverage using a novel image fusion and optimization program.

    PubMed

    Zelefsky, Michael J; Cohen, Gilad N; Taggar, Amandeep S; Kollmeier, Marisa; McBride, Sean; Mageras, Gig; Zaider, Marco

    Our purpose was to describe the process and outcome of performing postimplantation dosimetric assessment and intraoperative dose correction during prostate brachytherapy using a novel image fusion-based treatment-planning program. Twenty-six consecutive patients underwent intraoperative real-time corrections of their dose distributions at the end of their permanent seed interstitial procedures. After intraoperatively planned seeds were implanted and while the patient remained in the lithotomy position, a cone beam computed tomography scan was obtained to assess adequacy of the prescription dose coverage. The implanted seed positions were automatically segmented from the cone-beam images, fused onto a new set of acquired ultrasound images, reimported into the planning system, and recontoured. Dose distributions were recalculated based upon actual implanted seed coordinates and recontoured ultrasound images and were reviewed. If any dose deficiencies within the prostate target were identified, additional needles and seeds were added. Once an implant was deemed acceptable, the procedure was completed, and anesthesia was reversed. When the intraoperative ultrasound-based quality assurance assessment was performed after seed placement, the median volume receiving 100% of the dose (V100) was 93% (range, 74% to 98%). Before seed correction, 23% (6/26) of cases were noted to have V100 <90%. Based on this intraoperative assessment and replanning, additional seeds were placed into dose-deficient regions within the target to improve target dose distributions. Postcorrection, the median V100 was 97% (range, 93% to 99%). Following intraoperative dose corrections, all implants achieved V100 >90%. In these patients, postimplantation evaluation during the actual prostate seed implant procedure was successfully applied to determine the need for additional seeds to correct dose deficiencies before anesthesia reversal. When applied, this approach should significantly reduce

  10. Multispectral open-air intraoperative fluorescence imaging.

    PubMed

    Behrooz, Ali; Waterman, Peter; Vasquez, Kristine O; Meganck, Jeff; Peterson, Jeffrey D; Faqir, Ilias; Kempner, Joshua

    2017-08-01

    Intraoperative fluorescence imaging informs decisions regarding surgical margins by detecting and localizing signals from fluorescent reporters, labeling targets such as malignant tissues. This guidance reduces the likelihood of undetected malignant tissue remaining after resection, eliminating the need for additional treatment or surgery. The primary challenges in performing open-air intraoperative fluorescence imaging come from the weak intensity of the fluorescence signal in the presence of strong surgical and ambient illumination, and the auto-fluorescence of non-target components, such as tissue, especially in the visible spectral window (400-650 nm). In this work, a multispectral open-air fluorescence imaging system is presented for translational image-guided intraoperative applications, which overcomes these challenges. The system is capable of imaging weak fluorescence signals with nanomolar sensitivity in the presence of surgical illumination. This is done using synchronized fluorescence excitation and image acquisition with real-time background subtraction. Additionally, the system uses a liquid crystal tunable filter for acquisition of multispectral images that are used to spectrally unmix target fluorescence from non-target auto-fluorescence. Results are validated by preclinical studies on murine models and translational canine oncology models.

  11. Intraoperative radiotherapy for patients with carcinoma of the pancreas. The Howard University Hospital experience, 1978-1986.

    PubMed Central

    Tuckson, W B; Goldson, A L; Ashayeri, E; Halyard-Richardson, M; DeWitty, R L; Leffall, L D

    1988-01-01

    During the period from 1978 to 1986, 106 patients were diagnosed with carcinoma of the pancreas; 30 of these patients were excluded from this study. Of the remaining 76 patients, 40 did not receive intraoperative radiotherapy (IORT) and were used as the nonrandomized control group for the 36 patients who did receive IORT after histologic confirmation of carcinoma of the pancreas. The records of 35 patients were available for review. The group receiving IORT ranged in ages from 43 to 89 years (20 males and 15 females). Seventeen patients had distant metastatic disease. The primary was located in the head of the pancreas in 32 and the body in three. No patient in this group had a curative resection. All patients were treated by a combination of biliary and gastric bypass prior to or concurrent with IORT. IORT was begun only after obtaining a histologic diagnosis and prior to the completion of any anastomosis. Necrotizing pancreatitis occurred in the treated group. There was no statistically significant difference in the survival of the nonrandomized control and treated groups. Images Fig. 1. Fig. 2. PMID:3389933

  12. Distal end side-to-side anastomoses of sequential vein graft to small target coronary arteries improve intraoperative graft flow

    PubMed Central

    2014-01-01

    Background End-to-side anastomoses to connect the distal end of the great saphenous vein (GSV) to small target coronary arteries are commonly performed in sequential coronary artery bypass grafting (CABG). However, the oversize diameter ratio between the GSV and small target vessels at end-to-side anastomoses might induce adverse hemodynamic condition. The purpose of this study was to describe a distal end side-to-side anastomosis technique and retrospectively compare the effect of distal end side-to-side versus end-to-side anastomosis on graft flow characteristics. Methods We performed side-to-side anastomoses to connect the distal end of the GSV to small target vessels on 30 patients undergoing off-pump sequential CABG in our hospital between October 2012 and July 2013. Among the 30 patients, end-to-side anastomoses at the distal end of the GSV were initially performed on 14 patients; however, due to poor graft flow, those anastomoses were revised into side-to-side anastomoses. We retrospectively compared the intraoperative graft flow characteristics of the end-to-side versus side-to-side anastomoses in the 14 patients. The patient outcomes were also evaluated. Results We found that the side-to-side anastomosis reconstruction improved intraoperative flow and reduced pulsatility index in all the 14 patients significantly. The 16 patients who had the distal end side-to-side anastomoses performed directly also exhibited satisfactory intraoperative graft flow. Three-month postoperative outcomes for all the patients were satisfactory. Conclusions Side-to-side anastomosis at the distal end of sequential vein grafts might be a promising strategy to connect small target coronary arteries to the GSV. PMID:24884776

  13. Frequency of whole breast irradiation (WBRT) after intraoperative radiotherapy (IORT) is strongly influenced by institutional protocol qualification criteria.

    PubMed

    Falco, Michał; Masojć, Bartłomiej; Milchert-Leszczyńska, Marta; Kram, Andrzej

    2018-01-01

    Accelerated partial breast irradiation (APBI) is a promising method of adjuvant radiotherapy for select patients. Intraoperative radiotherapy (IORT) is a form of APBI, and appropriate patient selection is important. The aim of our study was to analyse the influence of our protocol on the frequency of WBRT after IORT and our protocol's correlation with the reported use of WBRT according to TARGIT guidelines. We also aimed to verify how changes in our protocol influenced the frequency of WBRT. Between April 20, 2010 and May 10, 2017, we identified 207 patients irradiated with IORT for APBI. Ninety-one patients (44%) met the criteria for APBI only, while 116 (56%) should have been offered additional WBRT. Retrospective analysis showed that WBRT was applied statistically significantly less frequently compared with strict protocol indications: 99 patients (47.8%) received APBI only and 108 (51.2%) underwent adjuvant WBRT ( p  < 0.0001). Applying the TARGIT trial guidelines, 69 patients (33.4%) should have been offered WBRT ( p  < 0.0001), which is twice the number of patients treated with WBRT in our study. Changing the protocol to less restrictive criteria would have statistically significantly decreased the number of patients (95, 46%) offered WBRT ( p  < 0.0001). Following international guidelines, 46% of patients should receive WBRT after IORT, which is 1.5-2 times more than for the TARGIT criteria. In our analysis, a high percentage of patients (19%) did not receive WBRT after IORT despite the protocol recommendations. The chosen protocol strongly influences the frequency of adjuvant WBRT.

  14. Are mammographic changes in the tumor bed more pronounced after intraoperative radiotherapy for breast cancer? Subgroup analysis from a randomized trial (TARGIT-A).

    PubMed

    Engel, Dorothee; Schnitzer, Andreas; Brade, Joachim; Blank, Elena; Wenz, Frederik; Suetterlin, Marc; Schoenberg, Stefan; Wasser, Klaus

    2013-01-01

    Intraoperative radiotherapy (IORT) with low-energy x-rays is increasingly used in breast-conserving therapy (BCT). Previous non-randomized studies have observed mammographic changes in the tumor bed to be more pronounced after IORT. The purpose of this study was to reassess the postoperative changes in a randomized single-center subgroup of patients from a multicenter trial (TARGIT-A). In this subgroup (n = 48) 27 patients received BCT with IORT, 21 patients had BCT with standard whole-breast radiotherapy serving as controls. Overall 258 postoperative mammograms (median follow-up 4.3 years, range 3-8) were retrospectively evaluated by two radiologists in consensus focusing on changes in the tumor bed. Fat necroses showed to be significantly more frequent (56% versus 24%) and larger (8.7 versus 1.6 sq cm, median) after IORT than those in controls. Scar calcifications were also significantly more frequent after IORT (63% versus 19%). The high incidence of large fat necroses in our study confirms previous study findings. However, the overall higher incidence of calcifications in the tumor bed after IORT represents a new finding, requiring further attention. © 2012 Wiley Periodicals, Inc.

  15. 4D imaging for target definition in stereotactic radiotherapy for lung cancer.

    PubMed

    Slotman, Ben J; Lagerwaard, Frank J; Senan, Suresh

    2006-01-01

    Stereotactic radiotherapy of Stage I lung tumors has been reported to result in high local control rates that are far superior to those obtained with conventional radiotherapy techniques, and which approach those achieved with primary surgery. Breathing-induced motion of tumor and target tissues is an important issue in this technique and careful attention should be paid to the contouring and the generation of individualized margins. We describe our experience with the use of 4DCT scanning for this group of patients, the use of post-processing tools and the potential benefits of respiratory gating.

  16. Intraoperative Ultrasound for Peripheral Nerve Applications.

    PubMed

    Willsey, Matthew; Wilson, Thomas J; Henning, Phillip Troy; Yang, Lynda J-S

    2017-10-01

    Offering real-time, high-resolution images via intraoperative ultrasound is advantageous for a variety of peripheral nerve applications. To highlight the advantages of ultrasound, its extraoperative uses are reviewed. The current intraoperative uses, including nerve localization, real-time evaluation of peripheral nerve tumors, and implantation of leads for peripheral nerve stimulation, are reviewed. Although intraoperative peripheral nerve localization has been performed previously using guide wires and surgical dyes, the authors' approach using ultrasound-guided instrument clamps helps guide surgical dissection to the target nerve, which could lead to more timely operations and shorter incisions. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Radionuclide 131I-labeled multifunctional dendrimers for targeted SPECT imaging and radiotherapy of tumors

    NASA Astrophysics Data System (ADS)

    Zhu, Jingyi; Zhao, Lingzhou; Cheng, Yongjun; Xiong, Zhijuan; Tang, Yueqin; Shen, Mingwu; Zhao, Jinhua; Shi, Xiangyang

    2015-10-01

    We report the synthesis, characterization, and utilization of radioactive 131I-labeled multifunctional dendrimers for targeted single-photon emission computed tomography (SPECT) imaging and radiotherapy of tumors. In this study, amine-terminated poly(amidoamine) dendrimers of generation 5 (G5.NH2) were sequentially modified with 3-(4'-hydroxyphenyl)propionic acid-OSu (HPAO) and folic acid (FA) linked with polyethylene glycol (PEG), followed by acetylation modification of the dendrimer remaining surface amines and labeling of radioactive iodine-131 (131I). The generated multifunctional 131I-G5.NHAc-HPAO-PEG-FA dendrimers were characterized via different methods. We show that prior to 131I labeling, the G5.NHAc-HPAO-PEG-FA dendrimers conjugated with approximately 9.4 HPAO moieties per dendrimer are noncytotoxic at a concentration up to 20 μM and are able to target cancer cells overexpressing FA receptors (FAR), thanks to the modified FA ligands. In the presence of a phenol group, radioactive 131I is able to be efficiently labeled onto the dendrimer platform with good stability and high radiochemical purity, and render the platform with an ability for targeted SPECT imaging and radiotherapy of an FAR-overexpressing xenografted tumor model in vivo. The designed strategy to use the facile dendrimer nanotechnology may be extended to develop various radioactive theranostic nanoplatforms for targeted SPECT imaging and radiotherapy of different types of cancer.We report the synthesis, characterization, and utilization of radioactive 131I-labeled multifunctional dendrimers for targeted single-photon emission computed tomography (SPECT) imaging and radiotherapy of tumors. In this study, amine-terminated poly(amidoamine) dendrimers of generation 5 (G5.NH2) were sequentially modified with 3-(4'-hydroxyphenyl)propionic acid-OSu (HPAO) and folic acid (FA) linked with polyethylene glycol (PEG), followed by acetylation modification of the dendrimer remaining surface amines and

  18. Astatine-211 imaging by a Compton camera for targeted radiotherapy.

    PubMed

    Nagao, Yuto; Yamaguchi, Mitsutaka; Watanabe, Shigeki; Ishioka, Noriko S; Kawachi, Naoki; Watabe, Hiroshi

    2018-05-24

    Astatine-211 is a promising radionuclide for targeted radiotherapy. It is required to image the distribution of targeted radiotherapeutic agents in a patient's body for optimization of treatment strategies. We proposed to image 211 At with high-energy photons to overcome some problems in conventional planar or single-photon emission computed tomography imaging. We performed an imaging experiment of a point-like 211 At source using a Compton camera, and demonstrated the capability of imaging 211 At with the high-energy photons for the first time. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Can Intraoperative Sensors Determine the "Target" Ligament Balance? Early Outcomes in Total Knee Arthroplasty.

    PubMed

    Meneghini, Robert M; Ziemba-Davis, Mary M; Lovro, Luke R; Ireland, Phillip H; Damer, Brent M

    2016-10-01

    The optimal "target" ligament balance for each patient undergoing total knee arthroplasty (TKA) remains unknown. The study purpose was to determine if patient outcomes are affected by intraoperative ligament balance measured with force-sensing implant trials and if an optimal "target" balance exists. A multicenter, retrospective study reviewed consecutive TKAs performed by 3 surgeons. TKA's were performed with standard surgical techniques and ligament releases. After final implants were made, sensor-embedded smart tibial trials were inserted, and compartment forces recorded throughout the range of motion. Clinical outcome measures were obtained preoperatively and at 4 months. Statistical analysis correlated ligament balance with clinical outcomes. One hundred eighty-nine consecutive TKAs were analyzed. Patients were grouped by average medial and lateral compartment force differences. Twenty-nine TKAs (15%) were balanced within 15 lbs and 53 (28%) were "balanced" greater than 75 lbs. Greater improvement in University of California Los Angeles activity level was associated with a mediolateral force difference <60 lbs. (P = .006). Knee Society objective, function, and satisfaction scores, and self-reported health state were unrelated to mediolateral balance in the knee. Intraoperative force-sensing has potential in providing real-time objective data to optimize TKA outcomes. These data support some early outcomes may improve by balancing TKAs within 60 lbs difference. Close follow-up is warranted to determine if gait pattern adaptations affect longer term outcomes with greater or less ligament "imbalance." Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Target margins in radiotherapy of prostate cancer

    PubMed Central

    Bauman, Glenn

    2016-01-01

    We reviewed the literature on the use of margins in radiotherapy of patients with prostate cancer, focusing on different options for image guidance (IG) and technical issues. The search in PubMed database was limited to include studies that involved external beam radiotherapy of the intact prostate. Post-prostatectomy studies, brachytherapy and particle therapy were excluded. Each article was characterized according to the IG strategy used: positioning on external marks using room lasers, bone anatomy and soft tissue match, usage of fiducial markers, electromagnetic tracking and adapted delivery. A lack of uniformity in margin selection among institutions was evident from the review. In general, introduction of pre- and in-treatment IG was associated with smaller planning target volume (PTV) margins, but there was a lack of definitive experimental/clinical studies providing robust information on selection of exact PTV values. In addition, there is a lack of comparative research regarding the cost–benefit ratio of the different strategies: insertion of fiducial markers or electromagnetic transponders facilitates prostate gland localization but at a price of invasive procedure; frequent pre-treatment imaging increases patient in-room time, dose and labour; online plan adaptation should improve radiation delivery accuracy but requires fast and precise computation. Finally, optimal protocols for quality assurance procedures need to be established. PMID:27377353

  1. SU-F-T-53: Treatment Planning with Inhomogeneity Correction for Intraoperative Radiotherapy Using KV X-Ray Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Y; Ghaly, M; Souri, S

    Purpose: The current standard in dose calculation for intraoperative radiotherapy (IORT) using the ZEISS Intrabeam 50 kV x-ray system is based on depth dose measurements in water and no heterogeneous tissue effect has been taken into account. We propose an algorithm for pre-treatment planning including inhomogeneity correction based on data of depth dose measurements in various tissue phantoms for kV x-rays. Methods: Direct depth dose measurements were made in air, water, inner bone and cortical bone phantoms for the Intrabeam 50 kV x-rays with a needle applicator. The data were modelled by a function of power law combining exponential withmore » different parameters. Those phantom slabs used in the measurements were scanned to obtain CT numbers. The x-ray beam initiated from the source isocenter is ray-traced through tissues. The corresponding doses will be deposited/assigned at different depths. On the boundary of tissue/organ changes, the x-ray beam will be re-traced in new tissue/organ starting at an equivalent depth with the same dose. In principle, a volumetric dose distribution can be generated if enough directional beams are traced. In practice, a several typical rays traced may be adequate in providing estimates of maximum dose to the organ at risk and minimum dose in the target volume. Results: Depth dose measurements and modeling are shown in Figure 1. The dose versus CT number is shown in Figure 2. A computer program has been written for Kypho-IORT planning using those data. A direct measurement through 2 mm solid water, 2 mm inner bone, and 1 mm solid water yields a dose rate of 7.7 Gy/min. Our calculation shows 8.1±0.4 Gy/min, consistent with the measurement within 5%. Conclusion: The proposed method can be used to more accurately calculate the dose by taking into account the heterogeneous effect. The further validation includes comparison with Monte Carlo simulation.« less

  2. Effect of Patient Set-up and Respiration motion on Defining Biological Targets for Image-Guided Targeted Radiotherapy

    NASA Astrophysics Data System (ADS)

    McCall, Keisha C.

    Identification and monitoring of sub-tumor targets will be a critical step for optimal design and evaluation of cancer therapies in general and biologically targeted radiotherapy (dose-painting) in particular. Quantitative PET imaging may be an important tool for these applications. Currently radiotherapy planning accounts for tumor motion by applying geometric margins. These margins create a motion envelope to encompass the most probable positions of the tumor, while also maintaining the appropriate tumor control and normal tissue complication probabilities. This motion envelope is effective for uniform dose prescriptions where the therapeutic dose is conformed to the external margins of the tumor. However, much research is needed to establish the equivalent margins for non-uniform fields, where multiple biological targets are present and each target is prescribed its own dose level. Additionally, the size of the biological targets and close proximity make it impractical to apply planning margins on the sub-tumor level. Also, the extent of high dose regions must be limited to avoid excessive dose to the surrounding tissue. As such, this research project is an investigation of the uncertainty within quantitative PET images of moving and displaced dose-painting targets, and an investigation of the residual errors that remain after motion management. This included characterization of the changes in PET voxel-values as objects are moved relative to the discrete sampling interval of PET imaging systems (SPECIFIC AIM 1). Additionally, the repeatability of PET distributions and the delineating dose-painting targets were measured (SPECIFIC AIM 2). The effect of imaging uncertainty on the dose distributions designed using these images (SPECIFIC AIM 3) has also been investigated. This project also included analysis of methods to minimize motion during PET imaging and reduce the dosimetric impact of motion/position-induced imaging uncertainty (SPECIFIC AIM 4).

  3. Innovations in Radiotherapy Technology.

    PubMed

    Feain, I J; Court, L; Palta, J R; Beddar, S; Keall, P

    2017-02-01

    Many low- and middle-income countries, together with remote and low socioeconomic populations within high-income countries, lack the resources and services to deal with cancer. The challenges in upgrading or introducing the necessary services are enormous, from screening and diagnosis to radiotherapy planning/treatment and quality assurance. There are severe shortages not only in equipment, but also in the capacity to train, recruit and retain staff as well as in their ongoing professional development via effective international peer-review and collaboration. Here we describe some examples of emerging technology innovations based on real-time software and cloud-based capabilities that have the potential to redress some of these areas. These include: (i) automatic treatment planning to reduce physics staffing shortages, (ii) real-time image-guided adaptive radiotherapy technologies, (iii) fixed-beam radiotherapy treatment units that use patient (rather than gantry) rotation to reduce infrastructure costs and staff-to-patient ratios, (iv) cloud-based infrastructure programmes to facilitate international collaboration and quality assurance and (v) high dose rate mobile cobalt brachytherapy techniques for intraoperative radiotherapy. Copyright © 2016 The Royal College of Radiologists. All rights reserved.

  4. Mathematical modelling of radiotherapy strategies for early breast cancer.

    PubMed

    Enderling, Heiko; Anderson, Alexander R A; Chaplain, Mark A J; Munro, Alastair J; Vaidya, Jayant S

    2006-07-07

    Targeted intraoperative radiotherapy (Targit) is a new concept of partial breast irradiation where single fraction radiotherapy is delivered directly to the tumour bed. Apart from logistic advantages, this strategy minimizes the risk of missing the tumour bed and avoids delay between surgery and radiotherapy. It is presently being compared with the standard fractionated external beam radiotherapy (EBRT) in randomized trials. In this paper we present a mathematical model for the growth and invasion of a solid tumour into a domain of tissue (in this case breast tissue), and then a model for surgery and radiation treatment of this tumour. We use the established linear-quadratic (LQ) model to compute the survival probabilities for both tumour cells and irradiated breast tissue and then simulate the effects of conventional EBRT and Targit. True local recurrence of the tumour could arise either from stray tumour cells, or the tumour bed that harbours morphologically normal cells having a predisposition to genetic changes, such as a loss of heterozygosity (LOH) in genes that are crucial for tumourigenesis, e.g. tumour suppressor genes (TSGs). Our mathematical model predicts that the single high dose of radiotherapy delivered by Targit would result in eliminating all these sources of recurrence, whereas the fractionated EBRT would eliminate stray tumour cells, but allow (by virtue of its very schedule) the cells with LOH in TSGs or cell-cycle checkpoint genes to pass on low-dose radiation-induced DNA damage and consequently mutations that may favour the development of a new tumour. The mathematical model presented here is an initial attempt to model a biologically complex phenomenon that has until now received little attention in the literature and provides a 'proof of principle' that it is possible to produce clinically testable hypotheses on the effects of different approaches of radiotherapy for breast cancer.

  5. Long-Term Outcomes With Intraoperative Radiotherapy as a Component of Treatment for Locally Advanced or Recurrent Uterine Sarcoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barney, Brandon M., E-mail: barney.brandon@mayo.edu; Petersen, Ivy A.; Dowdy, Sean C.

    2012-05-01

    Purpose: To report our institutional experience with intraoperative radiotherapy (IORT) as a component of treatment for women with locally advanced or recurrent uterine sarcoma. Methods and Materials: From 1990 to 2010, 16 women with primary (n = 3) or locoregionally recurrent (n = 13) uterine sarcoma received IORT as a component of combined modality treatment. Tumor histology studies found leiomyosarcoma (n = 9), endometrial stromal sarcoma (n = 4), and carcinosarcoma (n = 3). Surgery consisted of gross total resection in 2 patients, subtotal resection in 6 patients, and resection with close surgical margins in 8 patients. The median IORTmore » dose was 12.5 Gy (range, 10-20 Gy). All patients received perioperative external beam radiotherapy (EBRT; median dose, 50.4 Gy; range, 20-62.5 Gy), and 6 patients also received perioperative systemic therapy. Results: Seven of the 16 patients are alive at a median follow-up of 44 months (range, 11-203 months). The 3-year Kaplan-Meier estimate of local relapse (within the EBRT field) was 7%, and central control (within the IORT field) was 100%. No local failures occurred in any of the 6 patients who underwent subtotal resection. The 3-year freedom from distant relapse was 48%, with failures occurring most frequently in the lungs or mediastinum. Median survival was 18 months, and 3-year Kaplan-Meier estimates of cause-specific and overall survival were 58% and 53%, respectively. Three patients (19%) experienced late Grade 3 toxicity. Conclusions: A combined modality approach with perioperative EBRT, surgery, and IORT for locally advanced or recurrent uterine sarcoma resulted in excellent local disease control with acceptable toxicity, even in patients with positive resection margins. With this approach, some patients were able to experience long-term freedom from recurrence.« less

  6. Registration of MRI to Intraoperative Radiographs for Target Localization in Spinal Interventions

    PubMed Central

    De Silva, T; Uneri, A; Ketcha, M D; Reaungamornrat, S; Goerres, J; Jacobson, M W; Vogt, S; Kleinszig, G; Khanna, A J; Wolinsky, J-P; Siewerdsen, J H

    2017-01-01

    Purpose Decision support to assist in target vertebra localization could provide a useful aid to safe and effective spine surgery. Previous solutions have shown 3D-2D registration of preoperative CT to intraoperative radiographs to reliably annotate vertebral labels for assistance during level localization. We present an algorithm (referred to as MR-LevelCheck) to perform 3D-2D registration based on a preoperative MRI to accommodate the increasingly common clinical scenario in which MRI is used instead of CT for preoperative planning. Methods Straightforward adaptation of gradient/intensity-based methods appropriate to CT-to-radiograph registration is confounded by large mismatch and noncorrespondence in image intensity between MRI and radiographs. The proposed method overcomes such challenges with a simple vertebrae segmentation step using vertebra centroids as seed points (automatically defined within existing workflow). Forwards projections are computed using segmented MRI and registered to radiographs via gradient orientation (GO) similarity and the CMA-ES (Covariance-Matrix-Adaptation Evolutionary-Strategy) optimizer. The method was tested in an IRB-approved study involving 10 patients undergoing cervical, thoracic, or lumbar spine surgery following preoperative MRI. Results The method successfully registered each preoperative MRI to intraoperative radiographs and maintained desirable properties of robustness against image content mismatch and large capture range. Robust registration performance was achieved with projection distance error (PDE) (median ± iqr) = 4.3 ± 2.6 mm (median ± iqr) and 0% failure rate. Segmentation accuracy for the continuous max-flow method yielded Dice coefficient = 88.1 ± 5.2, Accuracy = 90.6 ± 5.7, RMSE = 1.8 ± 0.6 mm, and contour affinity ratio (CAR) = 0.82 ± 0.08. Registration performance was found to be robust for segmentation methods exhibiting RMSE < 3 mm and CAR > 0.50. Conclusion The MR-LevelCheck method provides a

  7. [Clinical target volume delineation for radiotherapy of the esophagus].

    PubMed

    Lazarescu, I; Thureau, S; Nkhali, L; Pradier, O; Dubray, B

    2013-10-01

    The dense lymphatic network of the esophagus facilitates tumour spreading along the cephalo-caudal axis and to locoregional lymph nodes. A better understanding of microscopic invasion by tumour cells, based on histological analysis of surgical specimens and analysis of recurrence sites, has justified a reduction in radiotherapy target volumes. The delineation of the clinical target volume (CTV) depends on tumour characteristics (site, histology) and on its spread as assessed on endoscopic ultrasonography and ((18)F)-fluorodeoxyglucose positron-emission tomography (FDG-PET). We propose that positive and negative predictive values for FDG-PET should be used to adapt the CTV according to the risk of nodal involvement. Copyright © 2013 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  8. Strategies for systemic radiotherapy of micrometastases using antibody-targeted 131I.

    PubMed

    Wheldon, T E; O'Donoghue, J A; Hilditch, T E; Barrett, A

    1988-02-01

    A simple analysis is developed to evaluate the likely effectiveness of treatment of micrometastases by antibody-targeted 131I. Account is taken of the low levels of tumour uptake of antibody-conjugated 131I presently achievable and of the "energy wastage" in targeting microscopic tumours with a radionuclide whose disintegration energy is widely dissipated. The analysis shows that only modest doses can be delivered to micrometastases when total body dose is restricted to levels which allow recovery of bone marrow. Much higher doses could be delivered to micrometastases when bone marrow rescue is used. A rationale is presented for targeted systemic radiotherapy used in combination with external beam total body irradiation (TBI) and bone marrow rescue. This has some practical advantages. The effect of the targeted component is to impose a biological non-uniformity on the total body dose distribution with regions of high tumour cell density receiving higher doses. Where targeting results in high doses to particular normal organs (e.g. liver, kidney) the total dose to these organs could be kept within tolerable limits by appropriate shielding of the external beam radiation component of the treatment. Greater levels of tumour cell kill should be achievable by the combination regime without any increase in normal tissue damage over that inflicted by conventional TBI. The predicted superiority of the combination regime is especially marked for tumours just below the threshold for detectability (e.g. approximately 1 mm-1 cm diameter). This approach has the advantage that targeted radiotherapy provides only a proportion of the total body dose, most of which is given by a familiar technique. The proportion of dose given by the targeted component could be increased as experience is gained. The predicted superiority of the combination strategy should be experimentally testable using laboratory animals. Clinical applications should be cautiously approached, with due regard to

  9. Dosimetric feasibility of using tungsten-based functional paper for flexible chest wall protectors in intraoperative electron radiotherapy for breast cancer

    NASA Astrophysics Data System (ADS)

    Kamomae, Takeshi; Monzen, Hajime; Kawamura, Mariko; Okudaira, Kuniyasu; Nakaya, Takayoshi; Mukoyama, Takashi; Miyake, Yoshikazu; Ishihara, Yoshitomo; Itoh, Yoshiyuki; Naganawa, Shinji

    2018-01-01

    Intraoperative electron radiotherapy (IOERT), which is an accelerated partial breast irradiation method, has been used for early-stage breast cancer treatment. In IOERT, a protective disk is inserted behind the target volume to minimize the dose received by normal tissues. However, to use such a disk, the surgical incision must be larger than the field size because the disk is manufactured from stiff and unyielding materials. In this study, the applicability of newly developed tungsten-based functional paper (TFP) was assessed as an alternative to the existing protective disk. The radiation-shielding performance of the TFP was verified through experimental measurements and Monte Carlo simulations. Percentage depth dose curves and lateral dose profiles with and without TFPs were measured and simulated on a dedicated IOERT accelerator. The number of piled-up TFPs was changed from 1 to 40. In the experimental measurements, the relative doses at the exit plane of the TFPs for 9 MeV were 42.7%, 9.2%, 0.2%, and 0.1% with 10, 20, 30, and 40 TFPs, respectively, whereas those for 12 MeV were 63.6%, 27.1%, 8.6%, and 0.2% with 10, 20, 30, and 40 TFPs, respectively. Slight dose enhancements caused by backscatter radiation from the TFPs were observed at the entrance plane of the TFPs at both beam energies. The results of the Monte Carlo simulation indicated the same tendency as the experimental measurements. Based on the experimental and simulated results, the radiation-shielding performances of 30 TFPs for 9 MeV and 40 TFPs for 12 MeV were confirmed to be acceptable and close to those of the existing protective disk. The findings of this study suggest the feasibility of using TFPs as flexible chest wall protectors in IOERT for breast cancer treatment.

  10. Practical issues regarding angular and energy response in in vivo intraoperative electron radiotherapy dosimetry.

    PubMed

    López-Tarjuelo, Juan; Bouché-Babiloni, Ana; Morillo-Macías, Virginia; Santos-Serra, Agustín; Ferrer-Albiach, Carlos

    2017-01-01

    To estimate angular response deviation of MOSFETs in the realm of intraoperative electron radiotherapy (IOERT), review their energy dependence, and propose unambiguous names for detector rotations. MOSFETs have been used in IOERT. Movement of the detector, namely rotations, can spoil results. We propose yaw, pitch, and roll to name the three possible rotations in space, as these unequivocally name aircraft rotations. Reinforced mobile MOSFETs (model TN-502RDM-H) and an Elekta Precise linear accelerator were used. Two detectors were placed in air for the angular response study and the whole set of five detectors was calibrated as usual to evaluate energy dependence. The maximum readout was obtained with a roll of 90° and 4 MeV. With regard to pitch movement, a substantial drop in readout was achieved at 90°. Significant overresponse was measured at 315° with 4 MeV and at 45° with 15 MeV. Energy response is not different for the following groups of energies: 4, 6, and 9 MeV; and 12 MeV, 15 MeV, and 18 MeV. Our proposal to name MOSFET rotations solves the problem of defining sensor orientations. Angular response could explain lower than expected results when the tip of the detector is lifted due to inadvertent movements. MOSFETs energy response is independent of several energies and differs by a maximum of 3.4% when dependent. This can limit dosimetry errors and makes it possible to calibrate the detectors only once for each group of energies, which saves time and optimizes lifespan of MOSFETs.

  11. Nonrandom Intrafraction Target Motions and General Strategy for Correction of Spine Stereotactic Body Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ma Lijun, E-mail: lijunma@radonc.ucsf.ed; Sahgal, Arjun; Hossain, Sabbir

    2009-11-15

    Purpose: To characterize nonrandom intrafraction target motions for spine stereotactic body radiotherapy and to develop a method of correction via image guidance. The dependence of target motions, as well as the effectiveness of the correction strategy for lesions of different locations within the spine, was analyzed. Methods and Materials: Intrafraction target motions for 64 targets in 64 patients treated with a total of 233 fractions were analyzed. Based on the target location, the cases were divided into three groups, i.e., cervical (n = 20 patients), thoracic (n = 20 patients), or lumbar-sacrum (n = 24 patients) lesions. For each case,more » time-lag autocorrelation analysis was performed for each degree of freedom of motion that included both translations (x, y, and z shifts) and rotations (roll, yaw, and pitch). A general correction strategy based on periodic interventions was derived to determine the time interval required between two adjacent interventions, to overcome the patient-specific target motions. Results: Nonrandom target motions were detected for 100% of cases regardless of target locations. Cervical spine targets were found to possess the highest incidence of nonrandom target motion compared with thoracic and lumbar-sacral lesions (p < 0.001). The average time needed to maintain the target motion to within 1 mm of translation or 1 deg. of rotational deviation was 5.5 min, 5.9 min, and 7.1 min for cervical, thoracic, and lumbar-sacrum locations, respectively (at 95% confidence level). Conclusions: A high incidence of nonrandom intrafraction target motions was found for spine stereotactic body radiotherapy treatments. Periodic interventions at approximately every 5 minutes or less were needed to overcome such motions.« less

  12. In vivo dosimetry and acute toxicity in breast cancer patients undergoing intraoperative radiotherapy as boost

    PubMed Central

    Lee, Jason Joon Bock; Choi, Jinhyun; Ahn, Sung Gwe; Jeong, Joon; Lee, Ik Jae; Park, Kwangwoo; Kim, Kangpyo; Kim, Jun Won

    2017-01-01

    Purpose To report the results of a correlation analysis of skin dose assessed by in vivo dosimetry and the incidence of acute toxicity. This is a phase 2 trial evaluating the feasibility of intraoperative radiotherapy (IORT) as a boost for breast cancer patients. Materials and Methods Eligible patients were treated with IORT of 20 Gy followed by whole breast irradiation (WBI) of 46 Gy. A total of 55 patients with a minimum follow-up of 1 month after WBI were evaluated. Optically stimulated luminescence dosimeter (OSLD) detected radiation dose delivered to the skin during IORT. Acute toxicity was recorded according to the Common Terminology Criteria for Adverse Events v4.0. Clinical parameters were correlated with seroma formation and maximum skin dose. Results Median follow-up after IORT was 25.9 weeks (range, 12.7 to 50.3 weeks). Prior to WBI, only one patient developed acute toxicity. Following WBI, 30 patients experienced grade 1 skin toxicity and three patients had grade 2 skin toxicity. Skin dose during IORT exceeded 5 Gy in two patients: with grade 2 complications around the surgical scar in one patient who received 8.42 Gy. Breast volume on preoperative images (p = 0.001), ratio of applicator diameter and breast volume (p = 0.002), and distance between skin and tumor (p = 0.003) showed significant correlations with maximum skin dose. conclusions IORT as a boost was well-tolerated among Korean women without severe acute complication. In vivo dosimetry with OSLD can help ensure safe delivery of IORT as a boost. PMID:28712278

  13. In vivo dosimetry and acute toxicity in breast cancer patients undergoing intraoperative radiotherapy as boost.

    PubMed

    Lee, Jason Joon Bock; Choi, Jinhyun; Ahn, Sung Gwe; Jeong, Joon; Lee, Ik Jae; Park, Kwangwoo; Kim, Kangpyo; Kim, Jun Won

    2017-06-01

    To report the results of a correlation analysis of skin dose assessed by in vivo dosimetry and the incidence of acute toxicity. This is a phase 2 trial evaluating the feasibility of intraoperative radiotherapy (IORT) as a boost for breast cancer patients. Eligible patients were treated with IORT of 20 Gy followed by whole breast irradiation (WBI) of 46 Gy. A total of 55 patients with a minimum follow-up of 1 month after WBI were evaluated. Optically stimulated luminescence dosimeter (OSLD) detected radiation dose delivered to the skin during IORT. Acute toxicity was recorded according to the Common Terminology Criteria for Adverse Events v4.0. Clinical parameters were correlated with seroma formation and maximum skin dose. Median follow-up after IORT was 25.9 weeks (range, 12.7 to 50.3 weeks). Prior to WBI, only one patient developed acute toxicity. Following WBI, 30 patients experienced grade 1 skin toxicity and three patients had grade 2 skin toxicity. Skin dose during IORT exceeded 5 Gy in two patients: with grade 2 complications around the surgical scar in one patient who received 8.42 Gy. Breast volume on preoperative images (p = 0.001), ratio of applicator diameter and breast volume (p = 0.002), and distance between skin and tumor (p = 0.003) showed significant correlations with maximum skin dose. IORT as a boost was well-tolerated among Korean women without severe acute complication. In vivo dosimetry with OSLD can help ensure safe delivery of IORT as a boost.

  14. Target volume motion during anal cancer image guided radiotherapy using cone-beam computed tomography.

    PubMed

    Brooks, Corrinne J; Bernier, Laurence; Hansen, Vibeke N; Tait, Diana M

    2018-05-01

    Literature regarding image-guidance and interfractional motion of the anal canal (AC) during anal cancer radiotherapy is sparse. This study investigates interfractional AC motion during anal cancer radiotherapy. Bone matched cone beam CT (CBCT) images were acquired for 20 patients receiving anal cancer radiotherapy allowing population systematic and random error calculations. 12 were selected to investigate interfractional AC motion. Primary anal gross tumour volume and clinical target volume (CTVa) were contoured on each CBCT. CBCT CTVa volumes were compared to planning CTVa. CBCT CTVa volumes were combined into a CBCT-CTVa envelope for each patient. Maximum distortion between each orthogonal border of the planning CTVa and CBCT-CTVa envelope was measured. Frequency, volume and location of CBCT-CTVa envelope beyond the planning target volume (PTVa) was analysed. Population systematic and random errors were 1 and 3 mm respectively. 112 CBCTs were analysed in the interfractional motion study. CTVa varied between each imaging session particularly T location patients of anorectal origin. CTVa border expansions ≥ 1 cm were seen inferiorly, anteriorly, posteriorly and left direction. The CBCT-CTVa envelope fell beyond the PTVa ≥ 50% imaging sessions (n = 5). Of these CBCT CTVa distortions beyond PTVa, 44% and 32% were in the upper and lower thirds of PTVa respectively. The AC is susceptible to volume changes and shape deformations. Care must be taken when calculating or considering reducing the PTV margin to the anus. Advances in knowledge: Within a limited field of research, this study provides further knowledge of how the AC deforms during anal cancer radiotherapy.

  15. Tumor spheroid model for the biologically targeted radiotherapy of neuroblastoma micrometastases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walker, K.A.; Mairs, R.; Murray, T.

    Neuroblastoma is a pediatric malignancy with a poor prognosis at least partly attributable to an early pattern of dissemination. New approaches to treatment of micrometastases include targeted radiotherapy using radiolabeled antibodies or molecules which are taken up preferentially by tumor cells. Multicellular tumor spheroids (MTS) resemble micrometastases during the avascular phase of their development. A human neuroblastoma cell line (NBl-G) was grown as MTS and incubated briefly with a radiolabeled monoclonal antibody ({sup 131}I-UJ13A) directed against neuroectodermal antigens. Spheroid response was evaluated in terms of regrowth delay or proportion sterilized. A dose-response relationship was demonstrated in terms of {sup 131}Imore » activity or duration of incubation. Control experiments using unlabeled UJ13A, radiolabeled nonspecific antibody (T2.10), radiolabeled human serum albumin, and radiolabeled sodium iodide showed these to be relatively ineffective compared to {sup 131}I-UJ13A. The cell line NBl-G grown as MTS has also been found to preferentially accumulate the radiolabeled catecholamine precursor molecule m-({sup 131}I)iodobenzylguanidine compared to cell lines derived from other tumor types. NBl-G cells grown as MTS provide a promising laboratory model for targeted radiotherapy of neuroblastoma micrometastases using radiolabeled antibodies or m-iodobenzylguanidine.« less

  16. Registration of MRI to intraoperative radiographs for target localization in spinal interventions

    NASA Astrophysics Data System (ADS)

    De Silva, T.; Uneri, A.; Ketcha, M. D.; Reaungamornrat, S.; Goerres, J.; Jacobson, M. W.; Vogt, S.; Kleinszig, G.; Khanna, A. J.; Wolinsky, J.-P.; Siewerdsen, J. H.

    2017-01-01

    Decision support to assist in target vertebra localization could provide a useful aid to safe and effective spine surgery. Previous solutions have shown 3D-2D registration of preoperative CT to intraoperative radiographs to reliably annotate vertebral labels for assistance during level localization. We present an algorithm (referred to as MR-LevelCheck) to perform 3D-2D registration based on a preoperative MRI to accommodate the increasingly common clinical scenario in which MRI is used instead of CT for preoperative planning. Straightforward adaptation of gradient/intensity-based methods appropriate to CT-to-radiograph registration is confounded by large mismatch and noncorrespondence in image intensity between MRI and radiographs. The proposed method overcomes such challenges with a simple vertebrae segmentation step using vertebra centroids as seed points (automatically defined within existing workflow). Forwards projections are computed using segmented MRI and registered to radiographs via gradient orientation (GO) similarity and the CMA-ES (covariance-matrix-adaptation evolutionary-strategy) optimizer. The method was tested in an IRB-approved study involving 10 patients undergoing cervical, thoracic, or lumbar spine surgery following preoperative MRI. The method successfully registered each preoperative MRI to intraoperative radiographs and maintained desirable properties of robustness against image content mismatch and large capture range. Robust registration performance was achieved with projection distance error (PDE) (median  ±  IQR)  =  4.3  ±  2.6 mm (median  ±  IQR) and 0% failure rate. Segmentation accuracy for the continuous max-flow method yielded dice coefficient  =  88.1  ±  5.2, accuracy  =  90.6  ±  5.7, RMSE  =  1.8  ±  0.6 mm, and contour affinity ratio (CAR)  =  0.82  ±  0.08. Registration performance was found to be robust for

  17. Prospective single-arm study of intraoperative radiotherapy for locally advanced or recurrent rectal cancer.

    PubMed

    Tan, Jennifer; Heriot, Alexander G; Mackay, Jack; Van Dyk, Sylvia; Bressel, Mathias Ab; Fox, Chris D; Hui, Andrew C; Lynch, A Craig; Leong, Trevor; Ngan, Samuel Y

    2013-10-01

    This study aims to evaluate the feasibility and outcomes of intraoperative radiotherapy (IORT) using high-dose-rate (HDR) brachytherapy for locally advanced or recurrent rectal cancers. Despite preoperative chemoradiation, patients with locally advanced or recurrent rectal cancers undergoing surgery remain at high risk of local recurrence. Intensification of radiation with IORT may improve local control. This is a prospective non-randomised study. Eligible patients were those with T4 rectal cancer or pelvic recurrence, deemed suitable for radical surgery but at high risk of positive resection margins, without evidence of metastasis. Chemoradiation was followed by radical surgery. Ten gray (Gy) was delivered to tumour bed via an IORT applicator at time of surgery. There were 15% primary and 85% recurrent cancers. The 71% received preoperative chemoradiation. R0, R1 and R2 resections were 70%, 22% and 7%, respectively. IORT was successfully delivered in 27 of 30 registered patients (90% (95% confidence interval (CI) = 73-98) ) at a median reported time of 12 weeks (interquartile range (IQR) = 10-16) after chemoradiation. Mean IORT procedure and delivery times were 63 minutes (range 22-105 minutes). Ten patients (37% (95% CI = 19-58) ) experienced grade 3 or 4 toxicities (three wound, four abscesses, three soft tissue, three bowel obstructions, three ureteric obstructions and two sensory neuropathies). Local recurrence-free, failure-free and overall survival rates at 2.5 years were 68% (95% CI = 52-89), 37% (95% CI = 23-61) and 82% (95% CI = 68-98), respectively. The addition of IORT to radical surgery for T4 or recurrent rectal cancer is feasible. It can be delivered safely with low morbidity and good tumour outcomes. © 2013 The Authors. Journal of Medical Imaging and Radiation Oncology © 2013 The Royal Australian and New Zealand College of Radiologists.

  18. Using injectable hydrogel markers to assess resimulation for boost target volume definition in a patient undergoing whole-breast radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patel, Henal; Goyal, Sharad; Kim, Leonard, E-mail: kimlh@rutgers.edu

    Several publications have recommended that patients undergoing whole-breast radiotherapy be resimulated for boost planning. The rationale for this is that the seroma may be smaller when compared with the initial simulation. However, the decision remains whether to use the earlier or later images to define an appropriate boost target volume. A patient undergoing whole-breast radiotherapy had new, injectable, temporary hydrogel fiducial markers placed 1 to 3 cm from the seroma at the time of initial simulation. The patient was resimulated 4.5 weeks later for conformal photon boost planning. Computed tomography (CT) scans acquired at the beginning and the end ofmore » whole-breast radiotherapy showed that shrinkage of the lumpectomy cavity was not matched by a corresponding reduction in the surrounding tissue volume, as demarcated by hydrogel markers. This observation called into question the usual interpretation of cavity shrinkage for boost target definition. For this patient, it was decided to define the boost target volume on the initial planning CT instead of the new CT.« less

  19. Intraoperative complications in pediatric neurosurgery: review of 1807 cases.

    PubMed

    van Lindert, Erik J; Arts, Sebastian; Blok, Laura M; Hendriks, Mark P; Tielens, Luc; van Bilsen, Martine; Delye, Hans

    2016-09-01

    OBJECTIVE Minimal literature exists on the intraoperative complication rate of pediatric neurosurgical procedures with respect to both surgical and anesthesiological complications. The aim of this study, therefore, was to establish intraoperative complication rates to provide patients and parents with information on which to base their informed consent and to establish a baseline for further targeted improvement of pediatric neurosurgical care. METHODS A clinical complication registration database comprising a consecutive cohort of all pediatric neurosurgical procedures carried out in a general neurosurgical department from January 1, 2004, until July 1, 2012, was analyzed. During the study period, 1807 procedures were performed on patients below the age of 17 years. RESULTS Sixty-four intraoperative complications occurred in 62 patients (3.5% of procedures). Intraoperative mortality was 0.17% (n = 3). Seventy-eight percent of the complications (n = 50) were related to the neurosurgical procedures, whereas 22% (n = 14) were due to anesthesiology. The highest intraoperative complication rates were for cerebrovascular surgery (7.7%) and tumor surgery (7.4%). The most frequently occurring complications were cerebrovascular complications (33%). CONCLUSIONS Intraoperative complications are not exceptional during pediatric neurosurgical procedures. Awareness of these complications is the first step in preventing them.

  20. Toward Intraoperative Image-Guided Transoral Robotic Surgery

    PubMed Central

    Liu, Wen P.; Reaugamornrat, Sureerat; Deguet, Anton; Sorger, Jonathan M.; Siewerdsen, Jeffrey H.; Richmon, Jeremy; Taylor, Russell H.

    2014-01-01

    This paper presents the development and evaluation of video augmentation on the stereoscopic da Vinci S system with intraoperative image guidance for base of tongue tumor resection in transoral robotic surgery (TORS). Proposed workflow for image-guided TORS begins by identifying and segmenting critical oropharyngeal structures (e.g., the tumor and adjacent arteries and nerves) from preoperative computed tomography (CT) and/or magnetic resonance (MR) imaging. These preoperative planned data can be deformably registered to the intraoperative endoscopic view using mobile C-arm cone-beam computed tomography (CBCT) [1, 2]. Augmentation of TORS endoscopic video defining surgical targets and critical structures has the potential to improve navigation, spatial orientation, and confidence in tumor resection. Experiments in animal specimens achieved statistically significant improvement in target localization error when comparing the proposed image guidance system to simulated current practice. PMID:25525474

  1. A multimodality segmentation framework for automatic target delineation in head and neck radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Jinzhong; Aristophanous, Michalis, E-mail: MAristophanous@mdanderson.org; Beadle, Beth M.

    2015-09-15

    Purpose: To develop an automatic segmentation algorithm integrating imaging information from computed tomography (CT), positron emission tomography (PET), and magnetic resonance imaging (MRI) to delineate target volume in head and neck cancer radiotherapy. Methods: Eleven patients with unresectable disease at the tonsil or base of tongue who underwent MRI, CT, and PET/CT within two months before the start of radiotherapy or chemoradiotherapy were recruited for the study. For each patient, PET/CT and T1-weighted contrast MRI scans were first registered to the planning CT using deformable and rigid registration, respectively, to resample the PET and magnetic resonance (MR) images to themore » planning CT space. A binary mask was manually defined to identify the tumor area. The resampled PET and MR images, the planning CT image, and the binary mask were fed into the automatic segmentation algorithm for target delineation. The algorithm was based on a multichannel Gaussian mixture model and solved using an expectation–maximization algorithm with Markov random fields. To evaluate the algorithm, we compared the multichannel autosegmentation with an autosegmentation method using only PET images. The physician-defined gross tumor volume (GTV) was used as the “ground truth” for quantitative evaluation. Results: The median multichannel segmented GTV of the primary tumor was 15.7 cm{sup 3} (range, 6.6–44.3 cm{sup 3}), while the PET segmented GTV was 10.2 cm{sup 3} (range, 2.8–45.1 cm{sup 3}). The median physician-defined GTV was 22.1 cm{sup 3} (range, 4.2–38.4 cm{sup 3}). The median difference between the multichannel segmented and physician-defined GTVs was −10.7%, not showing a statistically significant difference (p-value = 0.43). However, the median difference between the PET segmented and physician-defined GTVs was −19.2%, showing a statistically significant difference (p-value =0.0037). The median Dice similarity coefficient between the multichannel

  2. A multimodality segmentation framework for automatic target delineation in head and neck radiotherapy.

    PubMed

    Yang, Jinzhong; Beadle, Beth M; Garden, Adam S; Schwartz, David L; Aristophanous, Michalis

    2015-09-01

    To develop an automatic segmentation algorithm integrating imaging information from computed tomography (CT), positron emission tomography (PET), and magnetic resonance imaging (MRI) to delineate target volume in head and neck cancer radiotherapy. Eleven patients with unresectable disease at the tonsil or base of tongue who underwent MRI, CT, and PET/CT within two months before the start of radiotherapy or chemoradiotherapy were recruited for the study. For each patient, PET/CT and T1-weighted contrast MRI scans were first registered to the planning CT using deformable and rigid registration, respectively, to resample the PET and magnetic resonance (MR) images to the planning CT space. A binary mask was manually defined to identify the tumor area. The resampled PET and MR images, the planning CT image, and the binary mask were fed into the automatic segmentation algorithm for target delineation. The algorithm was based on a multichannel Gaussian mixture model and solved using an expectation-maximization algorithm with Markov random fields. To evaluate the algorithm, we compared the multichannel autosegmentation with an autosegmentation method using only PET images. The physician-defined gross tumor volume (GTV) was used as the "ground truth" for quantitative evaluation. The median multichannel segmented GTV of the primary tumor was 15.7 cm(3) (range, 6.6-44.3 cm(3)), while the PET segmented GTV was 10.2 cm(3) (range, 2.8-45.1 cm(3)). The median physician-defined GTV was 22.1 cm(3) (range, 4.2-38.4 cm(3)). The median difference between the multichannel segmented and physician-defined GTVs was -10.7%, not showing a statistically significant difference (p-value = 0.43). However, the median difference between the PET segmented and physician-defined GTVs was -19.2%, showing a statistically significant difference (p-value =0.0037). The median Dice similarity coefficient between the multichannel segmented and physician-defined GTVs was 0.75 (range, 0.55-0.84), and the

  3. Phase I-II Study of Intraoperative Radiation Therapy (IORT) After Radical Prostatectomy for Prostate Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saracino, Biancamaria; Gallucci, Michele; De Carli, Piero

    2008-07-15

    Purpose: Recent studies have suggested an {alpha}/{beta} ratio in prostate cancer of 1.5-3 Gy, which is lower than that assumed for late-responsive normal tissues. Therefore the administration of a single, intraoperative dose of irradiation should represent a convenient irradiation modality in prostate cancer. Materials and Methods: Between February 2002 and June 2004, 34 patients with localized prostate cancer with only one risk factor (Gleason score {>=}7, Clinical Stage [cT] {>=}2c, or prostate-specific antigen [PSA] of 11-20 ng/mL) and without clinical evidence of lymph node metastases were treated with radical prostatectomy (RP) and intraoperative radiotherapy on the tumor bed. A dose-findingmore » procedure based on the Fibonacci method was employed. Dose levels of 16, 18, and 20 Gy were selected, which are biologically equivalent to total doses of about 60-80 Gy administered with conventional fractionation, using an {alpha}/{beta} ratio value of 3. Results: At a median follow-up of 41 months, 24 (71%) patients were alive with an undetectable PSA value. No patients died from disease, whereas 2 patients died from other malignancies. Locoregional failures were detected in 3 (9%) patients, 2 in the prostate bed and 1 in the common iliac node chain outside the radiation field. A PSA rise without local or distant disease was observed in 7 (21%) cases. The overall 3-year biochemical progression-free survival rate was 77.3%. Conclusions: Our dose-finding study demonstrated the feasibility of intraoperative radiotherapy in prostate cancer also at the highest administered dose.« less

  4. Computer-aided placement of deep brain stimulators: from planning to intraoperative guidance

    NASA Astrophysics Data System (ADS)

    D'Haese, Pierre-Francois; Pallavaram, Srivatsan; Kao, Chris; Konrad, Peter E.; Dawant, Benoit M.

    2005-04-01

    The long term objective of our research is to develop a system that will automate as much as possible DBS implantation procedures. It is estimated that about 180,000 patients/year would benefit from DBS implantation. Yet, only 3000 procedures are performed annually. This is so because the combined expertise required to perform the procedure successfully is only available at a limited number of sites. Our goal is to transform this procedure into a procedure that can be performed by a general neurosurgeon at a community hospital. In this work we report on our current progress toward developing a system for the computer-assisted pre-operative selection of target points and for the intra-operative adjustment of these points. The system consists of a deformable atlas of optimal target points that can be used to select automatically the pre-operative target, of an electrophysiological atlas, and of an intra-operative interface. The atlas is deformed using a rigid then a non-rigid registration algorithm developed at our institution. Results we have obtained show that automatic prediction of target points is an achievable goal. Our results also indicate that electrophysiological information can be used to resolve structures not visible in anatomic images, thus improving both pre-operative and intra-operative guidance. Our intra-operative system has reached the stage of a working prototype that is clinically used at our institution.

  5. An efficient and robust MRI-guided radiotherapy planning approach for targeting abdominal organs and tumours in the mouse

    PubMed Central

    Bird, Luke; Tullis, Iain D. C.; Newman, Robert G.; Corroyer-Dulmont, Aurelien; Falzone, Nadia; Azad, Abul; Vallis, Katherine A.; Sansom, Owen J.; Muschel, Ruth J.; Vojnovic, Borivoj; Hill, Mark A.; Fokas, Emmanouil; Smart, Sean C.

    2017-01-01

    Introduction Preclinical CT-guided radiotherapy platforms are increasingly used but the CT images are characterized by poor soft tissue contrast. The aim of this study was to develop a robust and accurate method of MRI-guided radiotherapy (MR-IGRT) delivery to abdominal targets in the mouse. Methods A multimodality cradle was developed for providing subject immobilisation and its performance was evaluated. Whilst CT was still used for dose calculations, target identification was based on MRI. Each step of the radiotherapy planning procedure was validated initially in vitro using BANG gel dosimeters. Subsequently, MR-IGRT of normal adrenal glands with a size-matched collimated beam was performed. Additionally, the SK-N-SH neuroblastoma xenograft model and the transgenic KPC model of pancreatic ductal adenocarcinoma were used to demonstrate the applicability of our methods for the accurate delivery of radiation to CT-invisible abdominal tumours. Results The BANG gel phantoms demonstrated a targeting efficiency error of 0.56 ± 0.18 mm. The in vivo stability tests of body motion during MR-IGRT and the associated cradle transfer showed that the residual body movements are within this MR-IGRT targeting error. Accurate MR-IGRT of the normal adrenal glands with a size-matched collimated beam was confirmed by γH2AX staining. Regression in tumour volume was observed almost immediately post MR-IGRT in the neuroblastoma model, further demonstrating accuracy of x-ray delivery. Finally, MR-IGRT in the KPC model facilitated precise contouring and comparison of different treatment plans and radiotherapy dose distributions not only to the intra-abdominal tumour but also to the organs at risk. Conclusion This is, to our knowledge, the first study to demonstrate preclinical MR-IGRT in intra-abdominal organs. The proposed MR-IGRT method presents a state-of-the-art solution to enabling robust, accurate and efficient targeting of extracranial organs in the mouse and can operate with a

  6. Intraoperative radiotherapy using a mobile electron LINAC: a retroperitoneal sarcoma case.

    PubMed

    Beddar, A Sam; Krishnan, Sunil

    2005-01-01

    The advent of mobile LINACs for use in intraoperative radiation therapy (IORT) promises to make IORT more accessible than before and easier to deliver to patients undergoing surgery. Although mobile IORT systems have been available since 1999, few treatment centers currently use them. Here, we present the case of a typical patient undergoing IORT for retroperitoneal sarcoma to show how easy these mobile systems are to use and how adaptable they are within the operating room (OR) environment. We also discuss the roles and coordination of multidisciplinary team members during IORT and the feasibility of using mobile LINACs for IORT.

  7. Can the risk of secondary cancer induction after breast conserving therapy be reduced using intraoperative radiotherapy (IORT) with low-energy x-rays?

    PubMed

    Aziz, Muhammad Hammad; Schneider, Frank; Clausen, Sven; Blank, Elena; Herskind, Carsten; Afzal, Muhammad; Wenz, Frederik

    2011-12-16

    Radiation induced secondary cancers are a rare but severe late effect after breast conserving therapy. Intraoperative radiotherapy (IORT) is increasingly used during breast conserving surgery. The purpose of this analysis was to estimate secondary cancer risks after IORT compared to other modalities of breast radiotherapy (APBI - accelerated partial breast irradiation, EBRT - external beam radiotherapy). Computer-tomography scans of an anthropomorphic phantom were acquired with an INTRABEAM IORT applicator (diameter 4 cm) in the outer quadrant of the breast and transferred via DICOM to the treatment planning system. Ipsilateral breast, contralateral breast, ipsilateral lung, contralateral lung, spine and heart were contoured. An INTRABEAM source (50 kV) was defined with the tip of the drift tube at the center of the spherical applicator. A dose of 20 Gy at 0 mm depth from the applicator surface was prescribed for IORT and 34 Gy (5 days × 2 × 3.4 Gy) at 10 mm depth for APBI. For EBRT a total dose of 50 Gy in 2 Gy fractions was planned using two tangential fields with wedges. The mean and maximal doses, DVHs and volumes receiving more than 0.1 Gy and 4 Gy of organs at risk (OAR) were calculated and compared. The life time risk for secondary cancers was estimated according to NCRP report 116. IORT delivered the lowest maximal doses to contralateral breast (< 0.3 Gy), ipsilateral (1.8 Gy) and contralateral lung (< 0.3 Gy), heart (1 Gy) and spine (< 0.3 Gy). In comparison, maximal doses for APBI were 2-5 times higher. EBRT delivered a maximal dose of 10.4 Gy to the contralateral breast and 53 Gy to the ipsilateral lung. OAR volumes receiving more than 4 Gy were 0% for IORT, < 2% for APBI and up to 10% for EBRT (ipsilateral lung). The estimated risk for secondary cancer in the respective OAR is considerably lower after IORT and/or APBI as compared to EBRT. The calculations for maximal doses and volumes of OAR suggest that the risk of secondary cancer induction after

  8. Monte Carlo skin dose simulation in intraoperative radiotherapy of breast cancer using spherical applicators.

    PubMed

    Moradi, F; Ung, N M; Khandaker, M U; Mahdiraji, G A; Saad, M; Abdul Malik, R; Bustam, A Z; Zaili, Z; Bradley, D A

    2017-07-28

    The relatively new treatment modality electronic intraoperative radiotherapy (IORT) is gaining popularity, irradiation being obtained within a surgically produced cavity being delivered via a low-energy x-ray source and spherical applicators, primarily for early stage breast cancer. Due to the spatially dramatic dose-rate fall off with radial distance from the source and effects related to changes in the beam quality of the low keV photon spectra, dosimetric account of the Intrabeam system is rather complex. Skin dose monitoring in IORT is important due to the high dose prescription per treatment fraction. In this study, modeling of the x-ray source and related applicators were performed using the Monte Carlo N-Particle transport code. The dosimetric characteristics of the model were validated against measured data obtained using an ionization chamber and EBT3 film as dosimeters. By using a simulated breast phantom, absorbed doses to the skin for different combinations of applicator size (1.5-5 cm) and treatment depth (0.5-3 cm) were calculated. Simulation results showed overdosing of the skin (>30% of prescribed dose) at a treatment depth of 0.5 cm using applicator sizes larger than 1.5 cm. Skin doses were significantly increased with applicator size, insofar as delivering 12 Gy (60% of the prescribed dose) to skin for the largest sized applicator (5 cm diameter) and treatment depth of 0.5 cm. It is concluded that the recommended 0.5-1 cm distance between the skin and applicator surface does not guarantee skin safety and skin dose is generally more significant in cases with the larger applicators. • Intrabeam x-ray source and spherical applicators were simulated and skin dose was calculated. • Skin dose for constant skin to applicator distance strongly depends on applicator size. • Use of larger applicators generally results in higher skin dose. • The recommended 0.5-1 cm skin to applicator distance does not guarantee skin safety.

  9. Monte Carlo skin dose simulation in intraoperative radiotherapy of breast cancer using spherical applicators

    NASA Astrophysics Data System (ADS)

    Moradi, F.; Ung, N. M.; Khandaker, M. U.; Mahdiraji, G. A.; Saad, M.; Malik, R. Abdul; Bustam, A. Z.; Zaili, Z.; Bradley, D. A.

    2017-08-01

    The relatively new treatment modality electronic intraoperative radiotherapy (IORT) is gaining popularity, irradiation being obtained within a surgically produced cavity being delivered via a low-energy x-ray source and spherical applicators, primarily for early stage breast cancer. Due to the spatially dramatic dose-rate fall off with radial distance from the source and effects related to changes in the beam quality of the low keV photon spectra, dosimetric account of the Intrabeam system is rather complex. Skin dose monitoring in IORT is important due to the high dose prescription per treatment fraction. In this study, modeling of the x-ray source and related applicators were performed using the Monte Carlo N-Particle transport code. The dosimetric characteristics of the model were validated against measured data obtained using an ionization chamber and EBT3 film as dosimeters. By using a simulated breast phantom, absorbed doses to the skin for different combinations of applicator size (1.5-5 cm) and treatment depth (0.5-3 cm) were calculated. Simulation results showed overdosing of the skin (>30% of prescribed dose) at a treatment depth of 0.5 cm using applicator sizes larger than 1.5 cm. Skin doses were significantly increased with applicator size, insofar as delivering 12 Gy (60% of the prescribed dose) to skin for the largest sized applicator (5 cm diameter) and treatment depth of 0.5 cm. It is concluded that the recommended 0.5-1 cm distance between the skin and applicator surface does not guarantee skin safety and skin dose is generally more significant in cases with the larger applicators. Highlights: • Intrabeam x-ray source and spherical applicators were simulated and skin dose was calculated. • Skin dose for constant skin to applicator distance strongly depends on applicator size. • Use of larger applicators generally results in higher skin dose. • The recommended 0.5-1 cm skin to applicator distance does not guarantee skin

  10. [Task sharing with radiotherapy technicians in image-guided radiotherapy].

    PubMed

    Diaz, O; Lorchel, F; Revault, C; Mornex, F

    2013-10-01

    The development of accelerators with on-board imaging systems now allows better target volumes reset at the time of irradiation (image-guided radiotherapy [IGRT]). However, these technological advances in the control of repositioning led to a multiplication of tasks for each actor in radiotherapy and increase the time available for the treatment, whether for radiotherapy technicians or radiation oncologists. As there is currently no explicit regulatory framework governing the use of IGRT, some institutional experiments show that a transfer is possible between radiation oncologists and radiotherapy technicians for on-line verification of image positioning. Initial training for every technical and drafting procedures within institutions will improve audit quality by reducing interindividual variability. Copyright © 2013. Published by Elsevier SAS.

  11. Monte Carlo treatment planning for molecular targeted radiotherapy within the MINERVA system

    NASA Astrophysics Data System (ADS)

    Lehmann, Joerg; Hartmann Siantar, Christine; Wessol, Daniel E.; Wemple, Charles A.; Nigg, David; Cogliati, Josh; Daly, Tom; Descalle, Marie-Anne; Flickinger, Terry; Pletcher, David; DeNardo, Gerald

    2005-03-01

    The aim of this project is to extend accurate and patient-specific treatment planning to new treatment modalities, such as molecular targeted radiation therapy, incorporating previously crafted and proven Monte Carlo and deterministic computation methods. A flexible software environment is being created that allows planning radiation treatment for these new modalities and combining different forms of radiation treatment with consideration of biological effects. The system uses common input interfaces, medical image sets for definition of patient geometry and dose reporting protocols. Previously, the Idaho National Engineering and Environmental Laboratory (INEEL), Montana State University (MSU) and Lawrence Livermore National Laboratory (LLNL) had accrued experience in the development and application of Monte Carlo based, three-dimensional, computational dosimetry and treatment planning tools for radiotherapy in several specialized areas. In particular, INEEL and MSU have developed computational dosimetry systems for neutron radiotherapy and neutron capture therapy, while LLNL has developed the PEREGRINE computational system for external beam photon-electron therapy. Building on that experience, the INEEL and MSU are developing the MINERVA (modality inclusive environment for radiotherapeutic variable analysis) software system as a general framework for computational dosimetry and treatment planning for a variety of emerging forms of radiotherapy. In collaboration with this development, LLNL has extended its PEREGRINE code to accommodate internal sources for molecular targeted radiotherapy (MTR), and has interfaced it with the plugin architecture of MINERVA. Results from the extended PEREGRINE code have been compared to published data from other codes, and found to be in general agreement (EGS4—2%, MCNP—10%) (Descalle et al 2003 Cancer Biother. Radiopharm. 18 71-9). The code is currently being benchmarked against experimental data. The interpatient variability of

  12. An open label trial of folate receptor-targeted intraoperative molecular imaging to localize pulmonary squamous cell carcinomas

    PubMed Central

    Predina, Jarrod D.; Newton, Andrew D.; Xia, Leilei; Corbett, Christopher; Connolly, Courtney; Shin, Michael; Sulyok, Lydia Frezel; Litzky, Leslie; Deshpande, Charuhas; Nie, Shuming; Kularatne, Sumith A.; Low, Philip S.; Singhal, Sunil

    2018-01-01

    Background Clinical applicability of folate receptor-targeted intraoperative molecular imaging (FR-IMI) has been established for surgically resectable pulmonary adenocarcinoma. A role for FR-IMI in other lung cancer histologies has not been studied. In this study, we evaluate feasibility of FR-IMI in patients undergoing pulmonary resection for squamous cell carcinomas (SCCs). Methods In a human clinical trial (NCT02602119), twelve subjects with pulmonary SCCs underwent FR-IMI with a near-infrared contrast agent that targets the folate receptor-α (FRα), OTL38. Near-infrared signal from tumors and benign lung was quantified to calculate tumor-to-background ratios (TBR). Folate receptor-alpha expression was characterized, and histopathologic correlative analyses were performed to evaluate patterns of OTL38 accumulation. An exploratory analysis was performed to determine patient and histopathologic variables that predict tumor fluorescence. Results 9 of 13 SCCs (in 9 of 12 of subjects) displayed intraoperative fluorescence upon NIR evaluation (median TBR, 3.9). OTL38 accumulated within SCCs in a FRα-dependent manner. FR-IMI was reliable in localizing nodules as small as 1.1 cm, and prevented conversion to thoracotomy for nodule localization in three subjects. Upon evaluation of patient and histopathologic variables, in situ fluorescence was associated with distance from the pleural surface, and was independent of alternative variables including tumor size and metabolic activity. Conclusions This work demonstrates that FR-IMI is potentially feasible in 70% of SCC patients, and that molecular imaging can improve localization during minimally invasive pulmonary resection. These findings complement previous data demonstrating that ∼98% of pulmonary adenocarcinomas are localized during FR-IMI and suggest broad applicability for NSCLC patients undergoing resection. PMID:29568374

  13. Intraoperative computed tomography.

    PubMed

    Tonn, J C; Schichor, C; Schnell, O; Zausinger, S; Uhl, E; Morhard, D; Reiser, M

    2011-01-01

    Intraoperative computed tomography (iCT) has gained increasing impact among modern neurosurgical techniques. Multislice CT with a sliding gantry in the OR provides excellent diagnostic image quality in the visualization of vascular lesions as well as bony structures including skull base and spine. Due to short acquisition times and a high spatial and temporal resolution, various modalities such as iCT-angiography, iCT-cerebral perfusion and the integration of intraoperative navigation with automatic re-registration after scanning can be performed. This allows a variety of applications, e.g. intraoperative angiography, intraoperative cerebral perfusion studies, update of cerebral and spinal navigation, stereotactic procedures as well as resection control in tumour surgery. Its versatility promotes its use in a multidisciplinary setting. Radiation exposure is comparable to standard CT systems outside the OR. For neurosurgical purposes, however, new hardware components (e.g. a radiolucent headholder system) had to be developed. Having a different range of applications compared to intraoperative MRI, it is an attractive modality for intraoperative imaging being comparatively easy to install and cost efficient.

  14. WE-AB-BRA-09: Registration of Preoperative MRI to Intraoperative Radiographs for Automatic Vertebral Target Localization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    De Silva, T; Uneri, A; Ketcha, M

    Purpose: Accurate localization of target vertebrae is essential to safe, effective spine surgery, but wrong-level surgery occurs with surprisingly high frequency. Recent research yielded the “LevelCheck” method for 3D-2D registration of preoperative CT to intraoperative radiographs, providing decision support for level localization. We report a new method (MR-LevelCheck) to perform 3D-2D registration based on preoperative MRI, presenting a solution for the increasingly common scenario in which MRI (not CT) is used for preoperative planning. Methods: Direct extension of LevelCheck is confounded by large mismatch in image intensity between MRI and radiographs. The proposed method overcomes such challenges with a simplemore » vertebrae segmentation. Using seed points at centroids, vertebrae are segmented using continuous max-flow method and dilated by 1.8 mm to include surrounding cortical bone (inconspicuous in T2w-MRI). MRI projections are computed (analogous to DRR) using segmentation and registered to intraoperative radiographs. The method was tested in a retrospective IRB-approved study involving 11 patients undergoing cervical, thoracic, or lumbar spine surgery following preoperative MRI. Registration accuracy was evaluated in terms of projection-distance-error (PDE) between the true and estimated location of vertebrae in each radiograph. Results: The method successfully registered each preoperative MRI to intraoperative radiographs and maintained desirable properties of robustness against image content mismatch, and large capture range. Segmentation achieved Dice coefficient = 89.2 ± 2.3 and mean-absolute-distance (MAD) = 1.5 ± 0.3 mm. Registration demonstrated robust performance under realistic patient variations, with PDE = 4.0 ± 1.9 mm (median ± iqr) and converged with run-time = 23.3 ± 1.7 s. Conclusion: The MR-LevelCheck algorithm provides an important extension to a previously validated decision support tool in spine surgery by extending its

  15. Is current clinical practice modified about intraoperative breast irradiation?

    PubMed

    Massa, Michela; Franchelli, Simonetta; Panizza, Renzo; Massa, Tiberio

    2016-04-01

    After the results obtained in the two randomized clinical trial, the ELIOT trial and the TARGIT-A trial, a heated debate is going on concerning the question of applying intraoperative radiotherapy (IORT) instead of postoperative whole breast irradiation (WBI) after breast conservative treatment. Currently, many centers are applying the IORT following the strict selection criteria dictated by the working groups American Society for Radiation Oncology (ASTRO) and Groupe Européen de Curiethérapie-European Society for Therapeutic Radiology and Oncology (GEC-ESTRO) and monitoring the oncological outcome together with radiation toxicity on breast tissue. The clinical experience of the Geneva University Hospital regarding the use of the Intrabeam system is evaluated and compared with current evidences.

  16. Mild intraoperative hypothermia during surgery for intracranial aneurysm.

    PubMed

    Todd, Michael M; Hindman, Bradley J; Clarke, William R; Torner, James C

    2005-01-13

    Surgery for intracranial aneurysm often results in postoperative neurologic deficits. We conducted a randomized trial at 30 centers to determine whether intraoperative cooling during open craniotomy would improve the outcome among patients with acute aneurysmal subarachnoid hemorrhage. A total of 1001 patients with a preoperative World Federation of Neurological Surgeons score of I, II, or III ("good-grade patients"), who had had a subarachnoid hemorrhage no more than 14 days before planned surgical aneurysm clipping, were randomly assigned to intraoperative hypothermia (target temperature, 33 degrees C, with the use of surface cooling techniques) or normothermia (target temperature, 36.5 degrees C). Patients were followed closely postoperatively and examined approximately 90 days after surgery, at which time a Glasgow Outcome Score was assigned. There were no significant differences between the group assigned to intraoperative hypothermia and the group assigned to normothermia in the duration of stay in the intensive care unit, the total length of hospitalization, the rates of death at follow-up (6 percent in both groups), or the destination at discharge (home or another hospital, among surviving patients). At the final follow-up, 329 of 499 patients in the hypothermia group had a Glasgow Outcome Score of 1 (good outcome), as compared with 314 of 501 patients in the normothermia group (66 percent vs. 63 percent; odds ratio, 1.14; 95 percent confidence interval, 0.88 to 1.48; P=0.32). Postoperative bacteremia was more common in the hypothermia group than in the normothermia group (5 percent vs. 3 percent, P=0.05). Intraoperative hypothermia did not improve the neurologic outcome after craniotomy among good-grade patients with aneurysmal subarachnoid hemorrhage. Copyright 2005 Massachusetts Medical Society.

  17. Electrons for intraoperative radiotherapy in selected breast-cancer patients: late results of the Montpellier phase II trial

    PubMed Central

    2013-01-01

    Background The Montpellier cancer institute phase II trial started in 2004 and evaluated the feasibility of intraoperative radiotherapy (IORT) technique given as a sole radiation treatment for patients with an excellent prognostic and very low recurrence risk. Methods Forty-two patients were included between 2004 and 2007. Inclusion criteria were patients ≥ 65 years old, T0-T1, N0, ductal invasive unifocal carcinoma, free-margin > 2 mm. IORT was delivered using dedicated linear accelerator. One fraction of 21 Gy was prescribed and specified at the 90% isodose using electrons. In vivo dosimetry was performed for all patients. Primary end-point was the quality index. Secondary endpoints were quality of life, local recurrences, cosmetic results, specific and overall survival. Results At inclusion, median age was 72 years (range, 66–80). Median tumor diameter was 10 mm. All patients received the total prescribed dose. No acute grade 3 toxicities were observed. Late cosmetic results were good at 5 years despite the poor agreement of accuracy assessment between patients and physicians. Four patients (9.5%) experienced a local failure and underwent salvage mastectomy. The 5 year-disease free survival is 92.7% (range 79.1−97.6). All patients are still alive with a median follow-up of 72 months (range 66–74). Conclusion Our results confirm with a long-term follow-up that exclusive partial breast IORT is feasible for early-breast cancer in selected patients. IORT provides good late cosmetics results and should be considered as a safe and very comfortable “one-step” treatment procedure. Nevertheless, patient assessments are essential for long-term quality results. PMID:23902825

  18. Targeted Alpha Therapy: The US DOE Tri-Lab (ORNL, BNL, LANL) Research Effort to Provide Accelerator-Produced 225Ac for Radiotherapy

    NASA Astrophysics Data System (ADS)

    John, Kevin

    2017-01-01

    Targeted radiotherapy is an emerging discipline of cancer therapy that exploits the biochemical differences between normal cells and cancer cells to selectively deliver a lethal dose of radiation to cancer cells, while leaving healthy cells relatively unperturbed. A broad overview of targeted alpha therapy including isotope production methods, and associated isotope production facility needs, will be provided. A more general overview of the US Department of Energy Isotope Program's Tri-Lab (ORNL, BNL, LANL) Research Effort to Provide Accelerator-Produced 225Ac for Radiotherapy will also be presented focusing on the accelerator-production of 225Ac and final product isolation methodologies for medical applications.

  19. Combined-modality treatment of solid tumors using radiotherapy and molecular targeted agents.

    PubMed

    Ma, Brigette B Y; Bristow, Robert G; Kim, John; Siu, Lillian L

    2003-07-15

    Molecular targeted agents have been combined with radiotherapy (RT) in recent clinical trials in an effort to optimize the therapeutic index of RT. The appeal of this strategy lies in their potential target specificity and clinically acceptable toxicity. This article integrates the salient, published research findings into the underlying molecular mechanisms, preclinical efficacy, and clinical applicability of combining RT with molecular targeted agents. These agents include inhibitors of intracellular signal transduction molecules, modulators of apoptosis, inhibitors of cell cycle checkpoints control, antiangiogenic agents, and cyclo-oxygenase-2 inhibitors. Molecular targeted agents can have direct effects on the cytoprotective and cytotoxic pathways implicated in the cellular response to ionizing radiation (IR). These pathways involve cellular proliferation, DNA repair, cell cycle progression, nuclear transcription, tumor angiogenesis, and prostanoid-associated inflammation. These pathways can also converge to alter RT-induced apoptosis, terminal growth arrest, and reproductive cell death. Pharmacologic modulation of these pathways may potentially enhance tumor response to RT though inhibition of tumor repopulation, improvement of tumor oxygenation, redistribution during the cell cycle, and alteration of intrinsic tumor radiosensitivity. Combining RT and molecular targeted agents is a rational approach in the treatment of solid tumors. Translation of this approach from promising preclinical data to clinical trials is actively underway.

  20. Intensity-Modulated Radiotherapy for Craniospinal Irradiation: Target Volume Considerations, Dose Constraints, and Competing Risks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parker, William; Filion, Edith; Roberge, David

    2007-09-01

    Purpose: To report the results of an analysis of dose received to tissues and organs outside the target volume, in the setting of spinal axis irradiation for the treatment of medulloblastoma, using three treatment techniques. Methods and Materials: Treatment plans (total dose, 23.4 Gy) for a standard two-dimensional (2D) technique, a three-dimensional (3D) technique using a 3D imaging-based target volume, and an intensity-modulated radiotherapy (IMRT) technique, were compared for 3 patients in terms of dose-volume statistics for target coverage, as well as organ at risk (OAR) and overall tissue sparing. Results: Planning target volume coverage and dose homogeneity was superiormore » for the IMRT plans for V{sub 95%} (IMRT, 100%; 3D, 96%; 2D, 98%) and V{sub 107%} (IMRT, 3%; 3D, 38%; 2D, 37%). In terms of OAR sparing, the IMRT plan was better for all organs and whole-body contour when comparing V{sub 10Gy}, V{sub 15Gy}, and V{sub 20Gy}. The 3D plan was superior for V{sub 5Gy} and below. For the heart and liver in particular, the IMRT plans provided considerable sparing in terms of V{sub 10Gy} and above. In terms of the integral dose, the IMRT plans were superior for liver (IMRT, 21.9 J; 3D, 28.6 J; 2D, 38.6 J) and heart (IMRT, 9 J; 3D, 14.1J; 2D, 19.4 J), the 3D plan for the body contour (IMRT, 349 J; 3D, 337 J; 2D, 555 J). Conclusions: Intensity-modulated radiotherapy is a valid treatment option for spinal axis irradiation. We have shown that IMRT results in sparing of organs at risk without a significant increase in integral dose.« less

  1. Planning magnetic resonance imaging for prostate cancer intensity-modulated radiation therapy: Impact on target volumes, radiotherapy dose and androgen deprivation administration.

    PubMed

    Horsley, Patrick J; Aherne, Noel J; Edwards, Grace V; Benjamin, Linus C; Wilcox, Shea W; McLachlan, Craig S; Assareh, Hassan; Welshman, Richard; McKay, Michael J; Shakespeare, Thomas P

    2015-03-01

    Magnetic resonance imaging (MRI) scans are increasingly utilized for radiotherapy planning to contour the primary tumors of patients undergoing intensity-modulated radiation therapy (IMRT). These scans may also demonstrate cancer extent and may affect the treatment plan. We assessed the impact of planning MRI detection of extracapsular extension, seminal vesicle invasion, or adjacent organ invasion on the staging, target volume delineation, doses, and hormonal therapy of patients with prostate cancer undergoing IMRT. The records of 509 consecutive patients with planning MRI scans being treated with IMRT for prostate cancer between January 2010 and July 2012 were retrospectively reviewed. Tumor staging and treatment plans before and after MRI were compared. Of the 509 patients, 103 (20%) were upstaged and 44 (9%) were migrated to a higher risk category as a result of findings at MRI. In 94 of 509 patients (18%), the MRI findings altered management. Ninety-four of 509 patients (18%) had a change to their clinical target volume (CTV) or treatment technique, and in 41 of 509 patients (8%) the duration of hormone therapy was changed because of MRI findings. The use of radiotherapy planning MRI altered CTV design, dose and/or duration of androgen deprivation in 18% of patients in this large, single institution series of men planned for dose-escalated prostate IMRT. This has substantial implications for radiotherapy target volumes and doses, as well as duration of androgen deprivation. Further research is required to investigate whether newer MRI techniques can simultaneously fulfill staging and radiotherapy contouring roles. © 2014 Wiley Publishing Asia Pty Ltd.

  2. Evaluating 99mTc Auger electrons for targeted tumor radiotherapy by computational methods.

    PubMed

    Tavares, Adriana Alexandre S; Tavares, João Manuel R S

    2010-07-01

    Technetium-99m (99mTc) has been widely used as an imaging agent but only recently has been considered for therapeutic applications. This study aims to analyze the potential use of 99mTc Auger electrons for targeted tumor radiotherapy by evaluating the DNA damage and its probability of correct repair and by studying the cellular kinetics, following 99mTc Auger electron irradiation in comparison to iodine-131 (131I) beta minus particles and astatine-211 (211At) alpha particle irradiation. Computational models were used to estimate the yield of DNA damage (fast Monte Carlo damage algorithm), the probability of correct repair (Monte Carlo excision repair algorithm), and cell kinetic effects (virtual cell radiobiology algorithm) after irradiation with the selected particles. The results obtained with the algorithms used suggested that 99mTc CKMMX (all M-shell Coster-Kroning--CK--and super-CK transitions) electrons and Auger MXY (all M-shell Auger transitions) have a therapeutic potential comparable to high linear energy transfer 211At alpha particles and higher than 131I beta minus particles. All the other 99mTc electrons had a therapeutic potential similar to 131I beta minus particles. 99mTc CKMMX electrons and Auger MXY presented a higher probability to induce apoptosis than 131I beta minus particles and a probability similar to 211At alpha particles. Based on the results here, 99mTc CKMMX electrons and Auger MXY are useful electrons for targeted tumor radiotherapy.

  3. In vivo evaluation of a cancer therapy strategy combining HSV1716-mediated oncolysis with gene transfer and targeted radiotherapy.

    PubMed

    Sorensen, Annette; Mairs, Robert J; Braidwood, Lynne; Joyce, Craig; Conner, Joe; Pimlott, Sally; Brown, Moira; Boyd, Marie

    2012-04-01

    Oncolytic herpes viruses show promise for cancer treatment. However, it is unlikely that they will fulfill their therapeutic potential when used as monotherapies. An alternative strategy is to use these viruses not only as oncolytic agents but also as a delivery mechanism of therapeutic transgenes to enhance tumor cell killing. The herpes simplex virus 1 deletion mutant HSV1716 is a conditionally replicating oncolytic virus that selectively replicates in and lyses dividing tumor cells. It has a proven safety profile in clinical trials and has demonstrated efficacy as a gene-delivery vehicle. To enhance its therapeutic potential, we have engineered HSV1716 to convey the noradrenaline transporter (NAT) gene (HSV1716/NAT), whose expression endows infected cells with the capacity to accumulate the noradrenaline analog metaiodobenzylguanidine (MIBG). Thus, the NAT gene-infected cells are susceptible to targeted radiotherapy using radiolabeled (131)I-MIBG, a strategy that has already shown promise for combined targeted radiotherapy-gene therapy in cancer cells after plasmid-mediated transfection. We used HSV1716/NAT as a dual cell lysis-gene delivery vehicle for targeting the NAT transgene to human tumor xenografts in vivo. In tumor xenografts that did not express NAT, intratumoral or intravenous injection of HSV1716/NAT induced the capacity for active uptake of (131)I-MIBG. Administration of HSV1716/NAT and (131)I-MIBG resulted in decreased tumor growth and enhanced survival relative to injection of either agent alone. Efficacy was dependent on the scheduling of delivery of the 2 agents. These findings support a role for combination radiotherapy-gene therapy for cancer using HSV1716 expressing the NAT transgene and targeted radionuclide therapy.

  4. Intraoperative high-field magnetic resonance imaging, multimodal neuronavigation, and intraoperative electrophysiological monitoring-guided surgery for treating supratentorial cavernomas.

    PubMed

    Li, Fang-Ye; Chen, Xiao-Lei; Xu, Bai-Nan

    2016-09-01

    To determine the beneficial effects of intraoperative high-field magnetic resonance imaging (MRI), multimodal neuronavigation, and intraoperative electrophysiological monitoring-guided surgery for treating supratentorial cavernomas. Twelve patients with 13 supratentorial cavernomas were prospectively enrolled and operated while using a 1.5 T intraoperative MRI, multimodal neuronavigation, and intraoperative electrophysiological monitoring. All cavernomas were deeply located in subcortical areas or involved critical areas. Intraoperative high-field MRIs were obtained for the intraoperative "visualization" of surrounding eloquent structures, "brain shift" corrections, and navigational plan updates. All cavernomas were successfully resected with guidance from intraoperative MRI, multimodal neuronavigation, and intraoperative electrophysiological monitoring. In 5 cases with supratentorial cavernomas, intraoperative "brain shift" severely deterred locating of the lesions; however, intraoperative MRI facilitated precise locating of these lesions. During long-term (>3 months) follow-up, some or all presenting signs and symptoms improved or resolved in 4 cases, but were unchanged in 7 patients. Intraoperative high-field MRI, multimodal neuronavigation, and intraoperative electrophysiological monitoring are helpful in surgeries for the treatment of small deeply seated subcortical cavernomas.

  5. In vivo dosimetry in intraoperative electron radiotherapy: microMOSFETs, radiochromic films and a general-purpose linac.

    PubMed

    López-Tarjuelo, Juan; Bouché-Babiloni, Ana; Morillo-Macías, Virginia; de Marco-Blancas, Noelia; Santos-Serra, Agustín; Quirós-Higueras, Juan David; Ferrer-Albiach, Carlos

    2014-10-01

    In vivo dosimetry is desirable for the verification, recording, and eventual correction of treatment in intraoperative electron radiotherapy (IOERT). Our aim is to share our experience of metal oxide semiconductor field-effect transistors (MOSFETs) and radiochromic films with patients undergoing IOERT using a general-purpose linac. We used MOSFETs inserted into sterile bronchus catheters and radiochromic films that were cut, digitized, and sterilized by means of gas plasma. In all, 59 measurements were taken from 27 patients involving 15 primary tumors (seven breast and eight non-breast tumors) and 12 relapses. Data were subjected to an outliers' analysis and classified according to their compatibility with the relevant doses. Associations were sought regarding the type of detector, breast and non-breast irradiation, and the radiation oncologist's assessment of the difficulty of detector placement. At the same time, 19 measurements were carried out at the tumor bed with both detectors. MOSFET measurements ([Formula: see text]  = 93.5 %, sD  =  6.5 %) were not significantly shifted from film measurements ([Formula: see text]  =  96.0 %, sD  =  5.5 %; p  =  0.109), and no associations were found (p = 0.526, p = 0.295,  and p = 0.501, respectively). As regards measurements performed at the tumor bed with both detectors, MOSFET measurements ([Formula: see text]  =  95.0 %, sD  =  5.4 % were not significantly shifted from film measurements ([Formula: see text]  =  96.4 %, sD  =  5.0 %; p  =  0.363). In vivo dosimetry can produce satisfactory results at every studied location with a general-purpose linac. Detector choice should depend on user factors, not on the detector performance itself. Surgical team collaboration is crucial to success.

  6. A tri-modality image fusion method for target delineation of brain tumors in radiotherapy.

    PubMed

    Guo, Lu; Shen, Shuming; Harris, Eleanor; Wang, Zheng; Jiang, Wei; Guo, Yu; Feng, Yuanming

    2014-01-01

    To develop a tri-modality image fusion method for better target delineation in image-guided radiotherapy for patients with brain tumors. A new method of tri-modality image fusion was developed, which can fuse and display all image sets in one panel and one operation. And a feasibility study in gross tumor volume (GTV) delineation using data from three patients with brain tumors was conducted, which included images of simulation CT, MRI, and 18F-fluorodeoxyglucose positron emission tomography (18F-FDG PET) examinations before radiotherapy. Tri-modality image fusion was implemented after image registrations of CT+PET and CT+MRI, and the transparency weight of each modality could be adjusted and set by users. Three radiation oncologists delineated GTVs for all patients using dual-modality (MRI/CT) and tri-modality (MRI/CT/PET) image fusion respectively. Inter-observer variation was assessed by the coefficient of variation (COV), the average distance between surface and centroid (ADSC), and the local standard deviation (SDlocal). Analysis of COV was also performed to evaluate intra-observer volume variation. The inter-observer variation analysis showed that, the mean COV was 0.14(± 0.09) and 0.07(± 0.01) for dual-modality and tri-modality respectively; the standard deviation of ADSC was significantly reduced (p<0.05) with tri-modality; SDlocal averaged over median GTV surface was reduced in patient 2 (from 0.57 cm to 0.39 cm) and patient 3 (from 0.42 cm to 0.36 cm) with the new method. The intra-observer volume variation was also significantly reduced (p = 0.00) with the tri-modality method as compared with using the dual-modality method. With the new tri-modality image fusion method smaller inter- and intra-observer variation in GTV definition for the brain tumors can be achieved, which improves the consistency and accuracy for target delineation in individualized radiotherapy.

  7. Clinical target volume delineation in glioblastomas: pre-operative versus post-operative/pre-radiotherapy MRI

    PubMed Central

    Farace, P; Giri, M G; Meliadò, G; Amelio, D; Widesott, L; Ricciardi, G K; Dall'Oglio, S; Rizzotti, A; Sbarbati, A; Beltramello, A; Maluta, S; Amichetti, M

    2011-01-01

    Objectives Delineation of clinical target volume (CTV) is still controversial in glioblastomas. In order to assess the differences in volume and shape of the radiotherapy target, the use of pre-operative vs post-operative/pre-radiotherapy T1 and T2 weighted MRI was compared. Methods 4 CTVs were delineated in 24 patients pre-operatively and post-operatively using T1 contrast-enhanced (T1PRECTV and T1POSTCTV) and T2 weighted images (T2PRECTV and T2POSTCTV). Pre-operative MRI examinations were performed the day before surgery, whereas post-operative examinations were acquired 1 month after surgery and before chemoradiation. A concordance index (CI) was defined as the ratio between the overlapping and composite volumes. Results The volumes of T1PRECTV and T1POSTCTV were not statistically different (248 ± 88 vs 254 ± 101), although volume differences >100 cm3 were observed in 6 out of 24 patients. A marked increase due to tumour progression was shown in three patients. Three patients showed a decrease because of a reduced mass effect. A significant reduction occurred between pre-operative and post-operative T2 volumes (139 ± 68 vs 78 ± 59). Lack of concordance was observed between T1PRECTV and T1POSTCTV (CI = 0.67 ± 0.09), T2PRECTV and T2POSTCTV (CI = 0.39 ± 0.20) and comparing the portion of the T1PRECTV and T1POSTCTV not covered by that defined on T2PRECTV images (CI = 0.45 ± 0.16 and 0.44 ± 0.17, respectively). Conclusion Using T2 MRI, huge variations can be observed in peritumoural oedema, which are probably due to steroid treatment. Using T1 MRI, brain shifts after surgery and possible progressive enhancing lesions produce substantial differences in CTVs. Our data support the use of post-operative/pre-radiotherapy T1 weighted MRI for planning purposes. PMID:21045069

  8. Radiotherapy and "new" drugs-new side effects?

    PubMed Central

    2011-01-01

    Background and purpose Targeted drugs have augmented the cancer treatment armamentarium. Based on the molecular specificity, it was initially believed that these drugs had significantly less side effects. However, currently it is accepted that all of these agents have their specific side effects. Based on the given multimodal approach, special emphasis has to be placed on putative interactions of conventional cytostatic drugs, targeted agents and other modalities. The interaction of targeted drugs with radiation harbours special risks, since the awareness for interactions and even synergistic toxicities is lacking. At present, only limited is data available regarding combinations of targeted drugs and radiotherapy. This review gives an overview on the current knowledge on such combined treatments. Materials and methods Using the following MESH headings and combinations of these terms pubmed database was searched: Radiotherapy AND cetuximab/trastuzumab/panitumumab/nimotuzumab, bevacizumab, sunitinib/sorafenib/lapatinib/gefitinib/erlotinib/sirolimus, thalidomide/lenalidomide as well as erythropoietin. For citation crosscheck the ISI web of science database was used employing the same search terms. Results Several classes of targeted substances may be distinguished: Small molecules including kinase inhibitors and specific inhibitors, antibodies, and anti-angiogenic agents. Combination of these agents with radiotherapy may lead to specific toxicities or negatively influence the efficacy of RT. Though there is only little information on the interaction of molecular targeted radiation and radiotherapy in clinical settings, several critical incidents are reported. Conclusions The addition of molecular targeted drugs to conventional radiotherapy outside of approved regimens or clinical trials warrants a careful consideration especially when used in conjunction in hypo-fractionated regimens. Clinical trials are urgently needed in order to address the open question in regard

  9. Derlin-1 is a target to improve radiotherapy effect of esophageal squamous cell carcinoma

    PubMed Central

    Zhao, Yue; Liu, Yang; Li, Qingchang; Qiu, Xueshan; Wang, Enhua

    2017-01-01

    Radiotherapy is widely used for treatment of esophageal squamous cell carcinoma (ESCC). This study aimed to explore the role of Derlin-1 on the sensitivity of ESCC to radiotherapy and its underlying mechanism. We examined the clinical significance of Derlin-1 in 125 ESCC tissues. We found that Derlin-1 protein was higher in ESCC tissues than that in normal esophageal epithelial tissues. Derlin-1 overexpression was correlated with chemoradiotherapy resistance in ESCC patients and served an independent predictor for short overall survival. siRNA knockdown and plasmid transfection were carried out in ESCC cell lines. Derlin-1 depletion inhibited cell growth while its overexpression facilitated cell growth. Derlin-1 overexpression in Eca-109 cells dramatically enhanced its resistance to radiotherapy with decreased apoptosis rate. On the contrary, Derlin-1 depletion in TE-1 cell line showed the opposite effects. In addition, radioresistance conferred by Derlin-1 was attributed to its role of activating AKT/Bcl-2 signaling pathway and reducing caspase3 cleavage. Blockage of AKT signaling attenuated the role of Derlin-1 on radioresistance. Furthermore, Derlin-1 could interact with PI3K p110α in ESCC cell lines. Taken together, Our data demonstrate that Derlin-1 overexpression predicts poor prognosis and protects ESCC from irradiation induced apoptosis through PI3K/AKT/Bcl-2 signaling pathway. Derlin-1 may serve as a novel predictor for radiosentivity and a molecular target for ESCC. PMID:28903408

  10. A clip-based protocol for breast boost radiotherapy provides clear target visualisation and demonstrates significant volume reduction over time

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lewis, Lorraine; Cox, Jennifer; Faculty of Health Sciences, University of Sydney, Sydney, New South Wales

    2015-09-15

    The clinical target volume (CTV) for early stage breast cancer is difficult to clearly identify on planning computed tomography (CT) scans. Surgical clips inserted around the tumour bed should help to identify the CTV, particularly if the seroma has been reabsorbed, and enable tracking of CTV changes over time. A surgical clip-based CTV delineation protocol was introduced. CTV visibility and its post-operative shrinkage pattern were assessed. The subjects were 27 early stage breast cancer patients receiving post-operative radiotherapy alone and 15 receiving post-operative chemotherapy followed by radiotherapy. The radiotherapy alone (RT/alone) group received a CT scan at median 25 daysmore » post-operatively (CT1rt) and another at 40 Gy, median 68 days (CT2rt). The chemotherapy/RT group (chemo/RT) received a CT scan at median 18 days post-operatively (CT1ch), a planning CT scan at median 126 days (CT2ch), and another at 40 Gy (CT3ch). There was no significant difference (P = 0.08) between the initial mean CTV for each cohort. The RT/alone cohort showed significant CTV volume reduction of 38.4% (P = 0.01) at 40 Gy. The Chemo/RT cohort had significantly reduced volumes between CT1ch: median 54 cm{sup 3} (4–118) and CT2ch: median 16 cm{sup 3}, (2–99), (P = 0.01), but no significant volume reduction thereafter. Surgical clips enable localisation of the post-surgical seroma for radiotherapy targeting. Most seroma shrinkage occurs early, enabling CT treatment planning to take place at 7 weeks, which is within the 9 weeks recommended to limit disease recurrence.« less

  11. Minimally invasive surgery using intraoperative electron-beam radiotherapy for the treatment of soft tissue sarcoma of the extremities with tendon involvement.

    PubMed

    Matsumine, Akihiko; Tsujii, Masaya; Nakamura, Tomoki; Asanuma, Kunihiro; Matsubara, Takao; Kakimoto, Takuya; Yada, Yuki; Takada, Akinori; Ii, Noriko; Nomoto, Yoshihito; Sudo, Akihiro

    2016-08-12

    When a soft tissue sarcoma (STS) is located at the distal part of an extremity and involves the tendon, a wide excision usually causes severe functional disability. We therefore developed a minimally invasive surgical technique using intraoperative electron-beam radiotherapy (IOERT) to reduce the incidence of post-operative functional disability in patients with peri-/intra-tendinous STS. We assessed the clinical outcomes of the novel minimally invasive surgery. The study population included five patients who received treatment for distal extremity STSs. After elevating the tumor mass, including the tendon and nerve from the tumor bed with a wide margin, a lead board was inserted beneath the tumor mass to shield the normal tissue. IOERT (25-50 Gy) was then applied, and the tumor excised with care taken to maintain the continuity of the tendon. In a desmoid patient, local recurrence was observed outside the irradiated field. No cases of neuropathy or bone necrosis were observed. The mean limb function score was excellent in all patients. None of the high-grade sarcoma patients had local recurrence or distant metastasis. Although the current study is only a pilot study with a small number of patients, it shows that this minimally invasive procedure has the potential to become a standard treatment option for selected patients. H17-250 (registered 2 November 2005) and H25-250 (modified from H17-250, registered 5 December 2013).

  12. Implications of improved diagnostic imaging of small nodal metastases in head and neck cancer: Radiotherapy target volume transformation and dose de-escalation.

    PubMed

    van den Bosch, Sven; Vogel, Wouter V; Raaijmakers, Cornelis P; Dijkema, Tim; Terhaard, Chris H J; Al-Mamgani, Abrahim; Kaanders, Johannes H A M

    2018-05-03

    Diagnostic imaging continues to evolve, and now has unprecedented accuracy for detecting small nodal metastasis. This influences the tumor load in elective target volumes and subsequently has consequences for the radiotherapy dose required to control disease in these volumes. Small metastases that used to remain subclinical and were included in elective volumes, will nowadays be detected and included in high-dose volumes. Consequentially, high-dose volumes will more often contain low-volume disease. These target volume transformations lead to changes in the tumor burden in elective and "gross" tumor volumes with implications for the radiotherapy dose prescribed to these volumes. For head and neck tumors, nodal staging has evolved from mere palpation to combinations of high-resolution imaging modalities. A traditional nodal gross tumor volume in the neck typically had a minimum diameter of 10-15 mm, while nowadays much smaller tumor deposits are detected in lymph nodes. However, the current dose levels for elective nodal irradiation were empirically determined in the 1950s, and have not changed since. In this report the radiobiological consequences of target volume transformation caused by modern imaging of the neck are evaluated, and theoretically derived reductions of dose in radiotherapy for head and neck cancer are proposed. The concept of target volume transformation and subsequent strategies for dose adaptation applies to many other tumor types as well. Awareness of this concept may result in new strategies for target definition and selection of dose levels with the aim to provide optimal tumor control with less toxicity. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  13. Target dose conformity in 3-dimensional conformal radiotherapy and intensity modulated radiotherapy.

    PubMed

    Wu, Vincent W C; Kwong, Dora L W; Sham, Jonathan S T

    2004-05-01

    Dose conformity to the planning target volume is an important criterion in radiotherapy treatment planning, for which the conformity index is a useful assessment tool. The purpose of this study is to compare the differences in CI for the treatment planning of four cancers including the nasopharynx, oesophagus, lung and prostate. Seventy patients with cancers of nasopharynx (30), oesophagus (15), lung (15) and prostate (10) were recruited. Each of these patients was planned with three sets of treatment plans using the FOCUS treatment planning system: the forward and inverse 3DCRT plans and the IMRT plan. The CI was generated for each treatment plan. The mean CI from each cancer patient group was calculated and compared with the other three cancer groups. The mean value of CI was also compared among the three planning methods. The oesophageal and lung cancers demonstrated relatively higher overall mean CI values (0.64 and 0.62, respectively), whereas that of the nasopharynx and prostate were lower (0.54 and 0.50, respectively). With regards to the planning method groups, the IMRT plans produced the highest overall mean CI (0.62), while those for the forward and inverse 3DCRT were similar (0.57 and 0.55, respectively). For the four selected cancers, oesophageal and lung cancers were easier to conform than the nasopharyngeal and prostate cancers. The IMRT plans were more effective in achieving better dose conformity than that of the 3DCRT.

  14. MRI target delineation may reduce long-term toxicity after prostate radiotherapy.

    PubMed

    Sander, Lotte; Langkilde, Niels Christian; Holmberg, Mats; Carl, Jesper

    2014-06-01

    Aiming for minimal toxicity after radical prostate cancer (PC) radiotherapy (RT), magnetic resonance imaging (MRI) target delineation could be a possible benefit knowing that clinical target volumes (CTV) are up to 30% smaller, when CTV delineation on MRI is compared to standard computed tomography (CT). This study compares long-term toxicity using CT or MRI delineation before PC RT. Urinary and rectal toxicity assessments 36 months after image-guided RT (78 Gy) using CTC-AE scores in two groups of PC patients. Peak symptom score values were registered. One group of patients (n=72) had standard CT target delineation and gold markers as fiducials. Another group of patients (n=73) had MRI target delineation and a nickel-titanium stent as fiducial. At 36 months no difference in overall survival (92% in both groups, p=0.29) or in PSA-relapse free survival was found between the groups (MRI=89% and CT=94%, p=0.67). A significantly smaller CTV was found in the MRI group (p=0.02). Urinary retention and frequency were significantly reduced in the MRI group (p=0.03 in the matter of both). The overall urinary and rectal toxicity did not differ between the two groups. MRI delineation leads to a significantly reduced CTV. Significantly lower urinary frequency and urinary retention toxicity scores were observed following MRI delineation. The study did not find significant differences in overall urinary or rectal toxicity between the two groups. PSA-relapse survival did not differ between the two groups at 36 months.

  15. Prospective feasibility trial of radiotherapy target definition for head and neck cancer using 3-dimensional PET and CT imaging.

    PubMed

    Scarfone, Christopher; Lavely, William C; Cmelak, Anthony J; Delbeke, Dominique; Martin, William H; Billheimer, Dean; Hallahan, Dennis E

    2004-04-01

    The aim of this investigation was to evaluate the influence and accuracy of (18)F-FDG PET in target volume definition as a complementary modality to CT for patients with head and neck cancer (HNC) using dedicated PET and CT scanners. Six HNC patients were custom fitted with head and neck and upper body immobilization devices, and conventional radiotherapy CT simulation was performed together with (18)F-FDG PET imaging. Gross target volume (GTV) and pathologic nodal volumes were first defined in the conventional manner based on CT. A segmentation and surface-rendering registration technique was then used to coregister the (18)F-FDG PET and CT planning image datasets. (18)F-FDG PET GTVs were determined and displayed simultaneously with the CT contours. CT GTVs were then modified based on the PET data to form final PET/CT treatment volumes. Five-field intensity-modulated radiation therapy (IMRT) was then used to demonstrate dose targeting to the CT GTV or the PET/CT GTV. One patient was PET-negative after induction chemotherapy. The CT GTV was modified in all remaining patients based on (18)F-FDG PET data. The resulting PET/CT GTV was larger than the original CT volume by an average of 15%. In 5 cases, (18)F-FDG PET identified active lymph nodes that corresponded to lymph nodes contoured on CT. The pathologically enlarged CT lymph nodes were modified to create final lymph node volumes in 3 of 5 cases. In 1 of 6 patients, (18)F-FDG-avid lymph nodes were not identified as pathologic on CT. In 2 of 6 patients, registration of the independently acquired PET and CT data using segmentation and surface rendering resulted in a suboptimal alignment and, therefore, had to be repeated. Radiotherapy planning using IMRT demonstrated the capability of this technique to target anatomic or anatomic/physiologic target volumes. In this manner, metabolically active sites can be intensified to greater daily doses. Inclusion of (18)F-FDG PET data resulted in modified target volumes in

  16. Target coverage in image-guided stereotactic body radiotherapy of liver tumors.

    PubMed

    Wunderink, Wouter; Méndez Romero, Alejandra; Vásquez Osorio, Eliana M; de Boer, Hans C J; Brandwijk, René P; Levendag, Peter C; Heijmen, Ben J M

    2007-05-01

    To determine the effect of image-guided procedures (with computed tomography [CT] and electronic portal images before each treatment fraction) on target coverage in stereotactic body radiotherapy for liver patients using a stereotactic body frame (SBF) and abdominal compression. CT guidance was used to correct for day-to-day variations in the tumor's mean position in the SBF. By retrospectively evaluating 57 treatment sessions, tumor coverage, as obtained with the clinically applied CT-guided protocol, was compared with that of alternative procedures. The internal target volume-plus (ITV(+)) was introduced to explicitly include uncertainties in tumor delineations resulting from CT-imaging artifacts caused by residual respiratory motion. Tumor coverage was defined as the volume overlap of the ITV(+), derived from a tumor delineated in a treatment CT scan, and the planning target volume. Patient stability in the SBF, after acquisition of the treatment CT scan, was evaluated by measuring the displacement of the bony anatomy in the electronic portal images relative to CT. Application of our clinical protocol (with setup corrections following from manual measurements of the distances between the contours of the planning target volume and the daily clinical target volume in three orthogonal planes, multiple two-dimensional) increased the frequency of nearly full (> or = 99%) ITV(+) coverage to 77% compared with 63% without setup correction. An automated three-dimensional method further improved the frequency to 96%. Patient displacements in the SBF were generally small (< or = 2 mm, 1 standard deviation), but large craniocaudal displacements (maximal 7.2 mm) were occasionally observed. Daily, CT-assisted patient setup may substantially improve tumor coverage, especially with the automated three-dimensional procedure. In the present treatment design, patient stability in the SBF should be verified with portal imaging.

  17. Intraoperative loss of core biopsy clips: clinical implications.

    PubMed

    Calhoun, Kristine; Giuliano, Armando; Brenner, R James

    2008-03-01

    The purpose of this study was to report the occurrence of intraoperative loss of metallic marking clips placed during image-guided biopsy and to hypothesize the likely mechanism of this clinical problem. From January 2003 through December 2004, patients presenting for preoperative mammographic localization and operative excision of biopsy site marking clips were identified. Age, method of image-guided biopsy, number of excised specimens, and tissue diagnosis were determined. Specimen radiographs were used to identify cases of suspected intraoperative clip loss. Clips absent on specimen radiographs and postoperative mammograms were defined as lost intraoperatively. Biopsy site marking clips, surgical clips, and suction device apertures were measured. In 78 surgical procedures performed during the study period, three (3.8%) of the patients experienced clip loss. Specimen radiographs confirmed the absence of clips in all submitted tissues. A median of four (range, three to five) separate biopsy specimens were excised among these three cases. A healing biopsy site from the stereotactic biopsy preceding the clip placement procedure was confirmed in all cases. Absence of the metallic clip was confirmed on postoperative mammograms. The apertures of two types of suction device were four and two times those of the biopsy clips. Intraoperative loss of metallic clips placed at the conclusion of image-guided breast biopsy is unusual but can occur during subsequent surgical excision. Repeated inability to locate the clip on specimen radiographs after accurate preoperative localization should raise the suspicion that the target clip has been lost, not missed, during surgery, likely because of inadvertent removal of the clip with the suction device.

  18. Helical tomotherapy for radiotherapy in esophageal cancer: a preferred plan with better conformal target coverage and more homogeneous dose distribution.

    PubMed

    Chen, Yi-Jen; Liu, An; Han, Chunhui; Tsai, Peter T; Schultheiss, Timothy E; Pezner, Richard D; Vora, Nilesh; Lim, Dean; Shibata, Stephen; Kernstine, Kemp H; Wong, Jeffrey Y C

    2007-01-01

    We compare different radiotherapy techniques-helical tomotherapy (tomotherapy), step-and-shoot IMRT (IMRT), and 3-dimensional conformal radiotherapy (3DCRT)-for patients with mid-distal esophageal carcinoma on the basis of dosimetric analysis. Six patients with locally advanced mid-distal esophageal carcinoma were treated with neoadjuvant chemoradiation followed by surgery. Radiotherapy included 50 Gy to gross planning target volume (PTV) and 45 Gy to elective PTV in 25 fractions. Tomotherapy, IMRT, and 3DCRT plans were generated. Dose-volume histograms (DVHs), homogeneity index (HI), volumes of lung receiving more than 10, 15, or 20 Gy (V(10), V(15), V(20)), and volumes of heart receiving more than 30 or 45 Gy (V(30), V(45)) were determined. Statistical analysis was performed by paired t-tests. By isodose distributions and DVHs, tomotherapy plans showed sharper dose gradients, more conformal coverage, and better HI for both gross and elective PTVs compared with IMRT or 3DCRT plans. Mean V(20) of lung was significantly reduced in tomotherapy plans. However, tomotherapy and IMRT plans resulted in larger V(10) of lung compared to 3DCRT plans. The heart was significantly spared in tomotherapy and IMRT plans compared to 3DCRT plans in terms of V(30) and V(45). We conclude that tomotherapy plans are superior in terms of target conformity, dose homogeneity, and V(20) of lung.

  19. Improved visualization of intracranial vessels with intraoperative coregistration of rotational digital subtraction angiography and intraoperative 3D ultrasound.

    PubMed

    Podlesek, Dino; Meyer, Tobias; Morgenstern, Ute; Schackert, Gabriele; Kirsch, Matthias

    2015-01-01

    Ultrasound can visualize and update the vessel status in real time during cerebral vascular surgery. We studied the depiction of parent vessels and aneurysms with a high-resolution 3D intraoperative ultrasound imaging system during aneurysm clipping using rotational digital subtraction angiography as a reference. We analyzed 3D intraoperative ultrasound in 39 patients with cerebral aneurysms to visualize the aneurysm intraoperatively and the nearby vascular tree before and after clipping. Simultaneous coregistration of preoperative subtraction angiography data with 3D intraoperative ultrasound was performed to verify the anatomical assignment. Intraoperative ultrasound detected 35 of 43 aneurysms (81%) in 39 patients. Thirty-nine intraoperative ultrasound measurements were matched with rotational digital subtraction angiography and were successfully reconstructed during the procedure. In 7 patients, the aneurysm was partially visualized by 3D-ioUS or was not in field of view. Post-clipping intraoperative ultrasound was obtained in 26 and successfully reconstructed in 18 patients (69%) despite clip related artefacts. The overlap between 3D-ioUS aneurysm volume and preoperative rDSA aneurysm volume resulted in a mean accuracy of 0.71 (Dice coefficient). Intraoperative coregistration of 3D intraoperative ultrasound data with preoperative rotational digital subtraction angiography is possible with high accuracy. It allows the immediate visualization of vessels beyond the microscopic field, as well as parallel assessment of blood velocity, aneurysm and vascular tree configuration. Although spatial resolution is lower than for standard angiography, the method provides an excellent vascular overview, advantageous interpretation of 3D-ioUS and immediate intraoperative feedback of the vascular status. A prerequisite for understanding vascular intraoperative ultrasound is image quality and a successful match with preoperative rotational digital subtraction angiography.

  20. Development of a software for quantitative evaluation radiotherapy target and organ-at-risk segmentation comparison.

    PubMed

    Kalpathy-Cramer, Jayashree; Awan, Musaddiq; Bedrick, Steven; Rasch, Coen R N; Rosenthal, David I; Fuller, Clifton D

    2014-02-01

    Modern radiotherapy requires accurate region of interest (ROI) inputs for plan optimization and delivery. Target delineation, however, remains operator-dependent and potentially serves as a major source of treatment delivery error. In order to optimize this critical, yet observer-driven process, a flexible web-based platform for individual and cooperative target delineation analysis and instruction was developed in order to meet the following unmet needs: (1) an open-source/open-access platform for automated/semiautomated quantitative interobserver and intraobserver ROI analysis and comparison, (2) a real-time interface for radiation oncology trainee online self-education in ROI definition, and (3) a source for pilot data to develop and validate quality metrics for institutional and cooperative group quality assurance efforts. The resultant software, Target Contour Testing/Instructional Computer Software (TaCTICS), developed using Ruby on Rails, has since been implemented and proven flexible, feasible, and useful in several distinct analytical and research applications.

  1. Target position uncertainty during visually guided deep-inspiration breath-hold radiotherapy in locally advanced lung cancer.

    PubMed

    Scherman Rydhög, Jonas; Riisgaard de Blanck, Steen; Josipovic, Mirjana; Irming Jølck, Rasmus; Larsen, Klaus Richter; Clementsen, Paul; Lars Andersen, Thomas; Poulsen, Per Rugaard; Fredberg Persson, Gitte; Munck Af Rosenschold, Per

    2017-04-01

    The purpose of this study was to estimate the uncertainty in voluntary deep-inspiration breath-hold (DIBH) radiotherapy for locally advanced non-small cell lung cancer (NSCLC) patients. Perpendicular fluoroscopic movies were acquired in free breathing (FB) and DIBH during a course of visually guided DIBH radiotherapy of nine patients with NSCLC. Patients had liquid markers injected in mediastinal lymph nodes and primary tumours. Excursion, systematic- and random errors, and inter-breath-hold position uncertainty were investigated using an image based tracking algorithm. A mean reduction of 2-6mm in marker excursion in DIBH versus FB was seen in the anterior-posterior (AP), left-right (LR) and cranio-caudal (CC) directions. Lymph node motion during DIBH originated from cardiac motion. The systematic- (standard deviation (SD) of all the mean marker positions) and random errors (root-mean-square of the intra-BH SD) during DIBH were 0.5 and 0.3mm (AP), 0.5 and 0.3mm (LR), 0.8 and 0.4mm (CC), respectively. The mean inter-breath-hold shifts were -0.3mm (AP), -0.2mm (LR), and -0.2mm (CC). Intra- and inter-breath-hold uncertainty of tumours and lymph nodes were small in visually guided breath-hold radiotherapy of NSCLC. Target motion could be substantially reduced, but not eliminated, using visually guided DIBH. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Intraoperative diagnostics and elimination of residual microtumours with plasmonic nanobubbles

    NASA Astrophysics Data System (ADS)

    Lukianova-Hleb, Ekaterina Y.; Kim, Yoo-Shin; Belatsarkouski, Ihor; Gillenwater, Ann M.; O'Neill, Brian E.; Lapotko, Dmitri O.

    2016-06-01

    Failure of cancer surgery to intraoperatively detect and eliminate microscopic residual disease (MRD) causes lethal recurrence and metastases, and the removal of important normal tissues causes excessive morbidity. Here, we show that a plasmonic nanobubble (PNB), a non-stationary laser pulse-activated nanoevent, intraoperatively detects and eliminates MRD in the surgical bed. PNBs were generated in vivo in head and neck cancer cells by systemically targeting tumours with gold colloids and locally applying near-infrared, low-energy short laser pulses, and were simultaneously detected with an acoustic probe. In mouse models, between 3 and 30 residual cancer cells and MRD (undetectable with current methods) were non-invasively detected up to 4 mm deep in the surgical bed within 1 ms. In resectable MRD, PNB-guided surgery prevented local recurrence and delivered 100% tumour-free survival. In unresectable MRD, PNB nanosurgery improved survival twofold compared with standard surgery. Our results show that PNB-guided surgery and nanosurgery can rapidly and precisely detect and remove MRD in simple intraoperative procedures.

  3. Improved Visualization of Intracranial Vessels with Intraoperative Coregistration of Rotational Digital Subtraction Angiography and Intraoperative 3D Ultrasound

    PubMed Central

    Podlesek, Dino; Meyer, Tobias; Morgenstern, Ute; Schackert, Gabriele; Kirsch, Matthias

    2015-01-01

    Introduction Ultrasound can visualize and update the vessel status in real time during cerebral vascular surgery. We studied the depiction of parent vessels and aneurysms with a high-resolution 3D intraoperative ultrasound imaging system during aneurysm clipping using rotational digital subtraction angiography as a reference. Methods We analyzed 3D intraoperative ultrasound in 39 patients with cerebral aneurysms to visualize the aneurysm intraoperatively and the nearby vascular tree before and after clipping. Simultaneous coregistration of preoperative subtraction angiography data with 3D intraoperative ultrasound was performed to verify the anatomical assignment. Results Intraoperative ultrasound detected 35 of 43 aneurysms (81%) in 39 patients. Thirty-nine intraoperative ultrasound measurements were matched with rotational digital subtraction angiography and were successfully reconstructed during the procedure. In 7 patients, the aneurysm was partially visualized by 3D-ioUS or was not in field of view. Post-clipping intraoperative ultrasound was obtained in 26 and successfully reconstructed in 18 patients (69%) despite clip related artefacts. The overlap between 3D-ioUS aneurysm volume and preoperative rDSA aneurysm volume resulted in a mean accuracy of 0.71 (Dice coefficient). Conclusions Intraoperative coregistration of 3D intraoperative ultrasound data with preoperative rotational digital subtraction angiography is possible with high accuracy. It allows the immediate visualization of vessels beyond the microscopic field, as well as parallel assessment of blood velocity, aneurysm and vascular tree configuration. Although spatial resolution is lower than for standard angiography, the method provides an excellent vascular overview, advantageous interpretation of 3D-ioUS and immediate intraoperative feedback of the vascular status. A prerequisite for understanding vascular intraoperative ultrasound is image quality and a successful match with preoperative

  4. Intra-operative electron beam radiotherapy and abdomino-pelvic surgery for cancer: influence on immunological parameters.

    PubMed

    Bussières, E; Richaud, P; Gualde, N

    1992-10-01

    Evolution of some immunological parameters was observed during the first month in 20 patients with different abdomino-pelvic cancers who underwent surgery with intra-operative radiation therapy (IORT) (mean dose of 19.44 Gy, range 15, 25). Observed parameters before (DO-) and after procedure (DO+), on seventh (D7) and fourteenth (D14) days and fifth week (D30) were: lymphocyte count, lymphocyte subsets (CD19, CD3, CD4, CD8, CD56), natural killer (NK) activity, immunoglobulins, C3 and C4b fractions of complement, soluble receptor for interleukin 2 (sIL2-R). Results showed a decrease of circulating lymphocytes (DO-: 1189 +/- 168 cells/mm3; D7: 889 +/- 91; P = 0.011), of absolute number of CD3 lymphocytes (DO-: 785 +/- 114 cells/mm3; D7: 563 +/- 86; P = 0.025), of CD4 lymphocytes (DO-: 441 +/- 70 cells/mm3; DO+: 299 +/- 43; P = 0.013) and of CD8 lymphocytes (DO-:361 +/- 50 cells/mm3, D7:250 +/- 44; P = 0.006). All values returned towards preoperative levels by D30. Absolute number of NK cells was unchanged but NK activity was significantly diminished (effector target ratio 5:1 DO-:33 +/- 5%; DO+:44 +/- 7%; D7:18 +/- 3%; D14:21 +/- 4%; D30:25 +/- 4%). sIL2-R was significantly enhanced from D7 to D30. All these impairments are moderate and these observations provide some evidence of satisfactory tolerance to IORT for abdomino-pelvic cancers during the immediate postoperative period.

  5. Usefulness of intraoperative radiographs in reducing errors of cup placement and leg length during total hip arthroplasty.

    PubMed

    Wind, Michael A; Morrison, J Craig; Christie, Michael J

    2013-11-01

    Traditional methods of component placement during total hip arthroplasty (THA) can lead to errors in cup abduction angle and leg length. Intraoperative radiographs were used to assess and correct errors during surgery in a consecutive series of 278 THAs performed by a single surgeon. After exclusions, 262 cases were available for cup abduction angle assessment and 224 for leg length discrepancy (LLD) assessment. Components were initially placed in a position determined as appropriate by the surgeon. Intraoperative radiographs were taken and appropriate corrections made. Postoperative radiographs were assessed at 6 weeks. Mean abduction angle on intraoperative radiographs was 39.6°±5.9° versus 38.6°±4.1° on postoperative radiographs. Thirty-eight cups were outside the target abduction range on intraoperative radiographs versus 4 on postoperative radiographs. Mean LLD was 3.7 mm ± 3.6 mm on intraoperative radiographs and 2.5 mm ± 2.7 mm on postoperative radiographs. Use of intraoperative radiographs is a valid, useful technique for minimizing errors in THA.

  6. Radiotherapy for gastric lymphoma: a planning study of 3D conformal radiotherapy, the half-beam method, and intensity-modulated radiotherapy.

    PubMed

    Inaba, Koji; Okamoto, Hiroyuki; Wakita, Akihisa; Nakamura, Satoshi; Kobayashi, Kazuma; Harada, Ken; Kitaguchi, Mayuka; Sekii, Shuhei; Takahashi, Kana; Yoshio, Kotaro; Murakami, Naoya; Morota, Madoka; Ito, Yoshinori; Sumi, Minako; Uno, Takashi; Itami, Jun

    2014-11-01

    During radiotherapy for gastric lymphoma, it is difficult to protect the liver and kidneys in cases where there is considerable overlap between these organs and the target volume. This study was conducted to compare the three radiotherapy planning techniques of four-fields 3D conformal radiotherapy (3DCRT), half-field radiotherapy (the half-beam method) and intensity-modulated radiotherapy (IMRT) used to treat primary gastric lymphoma in which the planning target volume (PTV) had a large overlap with the left kidney. A total of 17 patients with gastric diffuse large B-cell lymphoma (DLBCL) were included. In DLBCL, immunochemotherapy (Rituximab + CHOP) was followed by radiotherapy of 40 Gy to the whole stomach and peri-gastric lymph nodes. 3DCRT, the half-field method, and IMRT were compared with respect to the dose-volume histogram (DVH) parameters and generalized equivalent uniform dose (gEUD) to the kidneys, liver and PTV. The mean dose and gEUD for 3DCRT was higher than for IMRT and the half-beam method in the left kidney and both kidneys. The mean dose and gEUD of the left kidney was 2117 cGy and 2224 cGy for 3DCRT, 1520 cGy and 1637 cGy for IMRT, and 1100 cGy and 1357 cGy for the half-beam method, respectively. The mean dose and gEUD of both kidneys was 1335 cGy and 1559 cGy for 3DCRT, 1184 cGy and 1311 cGy for IMRT, and 700 cGy and 937 cGy for the half-beam method, respectively. Dose-volume histograms (DVHs) of the liver revealed a larger volume was irradiated in the dose range <25 Gy with 3DCRT, while the half-beam method irradiated a larger volume of liver with the higher dose range (>25 Gy). IMRT and the half-beam method had the advantages of dose reduction for the kidneys and liver. © The Author 2014. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  7. PET imaging in adaptive radiotherapy of gastrointestinal tumours.

    PubMed

    Bulens, Philippe; Thomas, Melissa; Deroose, Christophe M; Haustermans, Karin

    2018-06-04

    Radiotherapy is the standard of care in the multimodality treatment of a variety of gastrointestinal (GI) tumours, such as oesophageal cancer, gastric cancer, rectal cancer and anal cancer. Additionally, radiotherapy has served as an alternative for surgery in patients with liver cancer, cancer of the biliary tract and pancreatic cancer. Positron-emission tomography (PET), generally in combination with computed tomography (CT), has an established role in the diagnosis, response assessment and (re-)staging of several GI tumours. However, the additional value of PET in adaptive radiotherapy, i.e. during the radiation treatment course and in the delineation process, is still unclear. When performed during radiotherapy, PET aims at assessing treatment-induced variations in functional tumour volumes to reduce the radiation target volume. Moreover, in the radiation treatment planning, tumour delineation could be more accurate by incorporating PET to identify the metabolic tumour volume. This review focuses on the additional value of PET for adaptive radiotherapy protocols as well as for the target volume adaptation for individualised treatment strategies in oesophageal, gastric, pancreatic, liver, biliary tract, rectal and anal neoplasms.

  8. Ultrashort courses of adjuvant breast radiotherapy: wave of the future or a fool's errand?

    PubMed

    Khan, Atif J; Dale, Roger G; Arthur, Douglas W; Haffty, Bruce G; Todor, Dorin A; Vicini, Frank A

    2012-04-15

    In accelerated partial breast irradiation (APBI), the most commonly used fractionation schemes include 340 or 385 centigrays delivered in a twice daily administration. A further progression of the APBI literature has been the recent interest in extremely short courses of adjuvant radiotherapy, usually delivered by intraoperative radiotherapy techniques. This newer area of single-fraction radiotherapy approaches remains highly contentious. In particular, the recently reported TARGIT trial has been the subject of both praise and scorn, and a critical examination of the trial data and the underlying hypotheses is warranted. Short-term outcomes of the related Italian ELIOT approach have also been reported. Although the assumptions of linear quadratic formalism are likely to hold true in the range of 2 to 8 grays, equating different schedules beyond this range is problematic. A major problem of current single-fraction approaches is that the treatment doses are chosen empirically, or are based on tolerability, or on the physical dose delivery characteristics of the chosen technology rather than radiobiological rationale. This review article summarizes the current data on ultrashort courses of adjuvant breast radiotherapy and highlights both the promise and the potential pitfalls of the abbreviated treatment. Copyright © 2011 American Cancer Society.

  9. Combining Targeted Agents With Modern Radiotherapy in Soft Tissue Sarcomas

    PubMed Central

    Wong, Philip; Houghton, Peter; Kirsch, David G.; Finkelstein, Steven E.; Monjazeb, Arta M.; Xu-Welliver, Meng; Dicker, Adam P.; Ahmed, Mansoor; Vikram, Bhadrasain; Teicher, Beverly A.; Coleman, C. Norman; Machtay, Mitchell; Curran, Walter J.

    2014-01-01

    Improved understanding of soft-tissue sarcoma (STS) biology has led to better distinction and subtyping of these diseases with the hope of exploiting the molecular characteristics of each subtype to develop appropriately targeted treatment regimens. In the care of patients with extremity STS, adjunctive radiation therapy (RT) is used to facilitate limb and function, preserving surgeries while maintaining five-year local control above 85%. In contrast, for STS originating from nonextremity anatomical sites, the rate of local recurrence is much higher (five-year local control is approximately 50%) and a major cause of death and morbidity in these patients. Incorporating novel technological advancements to administer accurate RT in combination with novel radiosensitizing agents could potentially improve local control and overall survival. RT efficacy in STS can be increased by modulating biological pathways such as angiogenesis, cell cycle regulation, cell survival signaling, and cancer-host immune interactions. Previous experiences, advancements, ongoing research, and current clinical trials combining RT with agents modulating one or more of the above pathways are reviewed. The standard clinical management of patients with STS with pretreatment biopsy, neoadjuvant treatment, and primary surgery provides an opportune disease model for interrogating translational hypotheses. The purpose of this review is to outline a strategic vision for clinical translation of preclinical findings and to identify appropriate targeted agents to combine with radiotherapy in the treatment of STS from different sites and/or different histology subtypes. PMID:25326640

  10. Theranostics of prostate cancer: from molecular imaging to precision molecular radiotherapy targeting the prostate specific membrane antigen.

    PubMed

    Kulkarni, Harshad R; Singh, Aviral; Langbein, Thomas; Schuchardt, Christiane; Mueller, Dirk; Zhang, Jingjing; Lehmann, Coline; Baum, Richard P

    2018-06-01

    Alterations at the molecular level are a hallmark of cancer. Prostate cancer is associated with the overexpression of prostate-specific membrane antigen (PSMA) in a majority of cases, predominantly in advanced tumors, increasing with the grade or Gleason's score. PSMA can be selectively targeted using radiolabeled PSMA ligands. These small molecules binding the PSMA can be radiolabeled with γ-emitters like 99m Tc and 111 In or positron emitters like 68 Ga and 18 F for diagnosis as well as with their theranostic pairs such as 177 Lu (β-emitter) or 225 Ac (α-emitter) for therapy. This review summarizes the theranostic role of PSMA ligands for molecular imaging and targeted molecular radiotherapy, moving towards precision oncology.

  11. Internal dosimetry through GATE simulations of preclinical radiotherapy using a melanin-targeting ligand

    NASA Astrophysics Data System (ADS)

    Perrot, Y.; Degoul, F.; Auzeloux, P.; Bonnet, M.; Cachin, F.; Chezal, J. M.; Donnarieix, D.; Labarre, P.; Moins, N.; Papon, J.; Rbah-Vidal, L.; Vidal, A.; Miot-Noirault, E.; Maigne, L.

    2014-05-01

    The GATE Monte Carlo simulation platform based on the Geant4 toolkit is under constant improvement for dosimetric calculations. In this study, we explore its use for the dosimetry of the preclinical targeted radiotherapy of melanoma using a new specific melanin-targeting radiotracer labeled with iodine 131. Calculated absorbed fractions and S values for spheres and murine models (digital and CT-scan-based mouse phantoms) are compared between GATE and EGSnrc Monte Carlo codes considering monoenergetic electrons and the detailed energy spectrum of iodine 131. The behavior of Geant4 standard and low energy models is also tested. Following the different authors’ guidelines concerning the parameterization of electron physics models, this study demonstrates an agreement of 1.2% and 1.5% with EGSnrc, respectively, for the calculation of S values for small spheres and mouse phantoms. S values calculated with GATE are then used to compute the dose distribution in organs of interest using the activity distribution in mouse phantoms. This study gives the dosimetric data required for the translation of the new treatment to the clinic.

  12. Intraoperative floppy iris and prevalence of intraoperative complications: results from ophthalmic surgery outcomes database.

    PubMed

    Vollman, David E; Gonzalez-Gonzalez, Luis A; Chomsky, Amy; Daly, Mary K; Baze, Elizabeth; Lawrence, Mary

    2014-06-01

    To estimate the prevalence of untoward events during cataract surgery with the use of pupillary expansion devices and intraoperative floppy iris (IFIS). Retrospective analysis of 4923 cataract surgery cases from the Veterans Affairs Ophthalmic Surgical Outcomes Data Project. Outcomes from 5 Veterans Affairs medical centers were analyzed, including use of alpha-blockers (both selective and nonselective), IFIS, intraoperative iris trauma, intraoperative iris prolapse, posterior capsular tear, anterior capsule tear, intraoperative vitreous prolapse, and use of pupillary expansion devices. P values were calculated using the χ(2) test. A total of 1254 patients (25.5%) took alpha-blockers preoperatively (selective, 587; nonselective, 627; both, 40). Of these 1254 patients, 428 patients (34.1%) had documented IFIS. However, 75.2% of patients with IFIS (428/569) had taken alpha-blockers preoperatively (P < .00001). A total of 430 patients (8.7%) had a pupillary expansion device used during their cataract surgery, of which 186 patients (43.4%) had IFIS (P < .0001). Eighty-six patients with IFIS had at least 1 intraoperative complication and 39 patients with IFIS had more than 1 intraoperative complication (P < .001). The use of either selective or nonselective alpha-antagonists preoperatively demonstrated a significant risk of IFIS. Nonselective alpha-antagonists caused IFIS at a higher prevalence than previously reported. This study did demonstrate statistically significant increased odds of surgical complications in patients with IFIS vs those without IFIS in all groups (those taking selective and nonselective alpha-antagonists and also those not taking medications). Published by Elsevier Inc.

  13. The impact of PET/CT scanning on the size of target volumes, radiation exposure of organs at risk, TCP and NTCP, in the radiotherapy planning of non-small cell lung cancer.

    PubMed

    Vojtíšek, Radovan; Mužík, Jan; Slampa, Pavel; Budíková, Marie; Hejsek, Jaroslav; Smolák, Petr; Ferda, Jiří; Fínek, Jindřich

    2014-05-01

    To compare radiotherapy plans made according to CT and PET/CT and to investigate the impact of changes in target volumes on tumour control probability (TCP), normal tissue complication probability (NTCP) and the impact of PET/CT on the staging and treatment strategy. Contemporary studies have proven that PET/CT attains higher sensitivity and specificity in the diagnosis of lung cancer and also leads to higher accuracy than CT alone in the process of target volume delineation in NSCLC. Between October 2009 and March 2012, 31 patients with locally advanced NSCLC, who had been referred to radical radiotherapy were involved in our study. They all underwent planning PET/CT examination. Then we carried out two separate delineations of target volumes and two radiotherapy plans and we compared the following parameters of those plans: staging, treatment purpose, the size of GTV and PTV and the exposure of organs at risk (OAR). TCP and NTCP were also compared. PET/CT information led to a significant decrease in the sizes of target volumes, which had the impact on the radiation exposure of OARs. The reduction of target volume sizes was not reflected in the significant increase of the TCP value. We found that there is a very strong direct linear relationship between all evaluated dosimetric parameters and NTCP values of all evaluated OARs. Our study found that the use of planning PET/CT in the radiotherapy planning of NSCLC has a crucial impact on the precise determination of target volumes, more precise staging of the disease and thus also on possible changes of treatment strategy.

  14. Deep Brain Stimulation of Heschl Gyrus: Implantation Technique, Intraoperative Localization, and Effects of Stimulation.

    PubMed

    Donovan, Chris; Sweet, Jennifer; Eccher, Matthew; Megerian, Cliff; Semaan, Maroun; Murray, Gail; Miller, Jonathan

    2015-12-01

    Tinnitus is a source of considerable morbidity, and neuromodulation has been shown to be a potential treatment option. However, the location of the primary auditory cortex within Heschl gyrus in the temporal operculum presents challenges for targeting and electrode implantation. To determine whether anatomic targeting with intraoperative verification using evoked potentials can be used to implant electrodes directly into the Heschl gyrus (HG). Nine patients undergoing stereo-electroencephalogram evaluation for epilepsy were enrolled. HG was directly targeted on volumetric magnetic resonance imaging, and framed stereotaxy was used to implant an electrode parallel to the axis of the gyrus by using an oblique anterolateral-posteromedial trajectory. Intraoperative evoked potentials from auditory stimuli were recorded from multiple electrode contacts. Postoperatively, stimulation of each electrode was performed and participants were asked to describe the percept. Audiometric analysis was performed for 2 participants during subthreshold stimulation. Sounds presented to the contralateral and ipsilateral ears produced evoked potentials in HG electrodes in all participants intraoperatively. Stimulation produced a reproducible sensation of sound in all participants with perceived volume proportional to amplitude. Four participants reported distinct sounds when different electrodes were stimulated, with more medial contacts producing tones perceived as higher in pitch. Stimulation was not associated with adverse audiometric effects. There were no complications of electrode implantation. Direct anatomic targeting with physiological verification can be used to implant electrodes directly into primary auditory cortex. If deep brain stimulation proves effective for intractable tinnitus, this technique may be useful to assist with electrode implantation. DBS, deep brain stimulatorEEG, electroencephalographyHG, Heschl gyrus.

  15. Delineation of clinical target volume for postoperative radiotherapy in stage IIIA-pN2 non-small-cell lung cancer

    PubMed Central

    Jing, Xuquan; Meng, Xue; Sun, Xindong; Yu, Jinming

    2016-01-01

    With the high locoregional relapse rate and the improvement of radiation technology, postoperative radiotherapy (PORT) has been widely used in the treatment of completely resected stage IIIA-pN2 non-small-cell lung cancer (NSCLC). However, there is still no definitive consensus on clinical target volume for the pN2 subgroup. This review will discuss how to delineate the clinical target volume (CTV) for pN2 subgroups of IIIA-N2 NSCLC based on the published literature and to investigate the optimal PORT CTV in this cohort of patients. Besides overall survival (OS), locoregional recurrence (LR), and radiotherapy-related toxicity of this subset of the population in the modern PORT era, selection of proper patients will also be considered in this review. In summary, it is appropriate to include involved lymph node stations and uninvolved stations at high risk in PORT CTV for patients with pN2 disease when PORT is administered. PORT can reduce LR and has the potential to improve OS. In the current era of modern radiation technology, PORT can be administered safely with well-tolerated toxicity. Clinicopathological characteristics may be helpful in selecting proper candidates for PORT. PMID:26929651

  16. Delineation of clinical target volume for postoperative radiotherapy in stage IIIA-pN2 non-small-cell lung cancer.

    PubMed

    Jing, Xuquan; Meng, Xue; Sun, Xindong; Yu, Jinming

    2016-01-01

    With the high locoregional relapse rate and the improvement of radiation technology, postoperative radiotherapy (PORT) has been widely used in the treatment of completely resected stage IIIA-pN2 non-small-cell lung cancer (NSCLC). However, there is still no definitive consensus on clinical target volume for the pN2 subgroup. This review will discuss how to delineate the clinical target volume (CTV) for pN2 subgroups of IIIA-N2 NSCLC based on the published literature and to investigate the optimal PORT CTV in this cohort of patients. Besides overall survival (OS), locoregional recurrence (LR), and radiotherapy-related toxicity of this subset of the population in the modern PORT era, selection of proper patients will also be considered in this review. In summary, it is appropriate to include involved lymph node stations and uninvolved stations at high risk in PORT CTV for patients with pN2 disease when PORT is administered. PORT can reduce LR and has the potential to improve OS. In the current era of modern radiation technology, PORT can be administered safely with well-tolerated toxicity. Clinicopathological characteristics may be helpful in selecting proper candidates for PORT.

  17. Intraoperative laparoscopic complications for urological cancer procedures.

    PubMed

    Montes, Sergio Fernández-Pello; Rodríguez, Ivan Gonzalez; Ugarteburu, Rodrigo Gil; Villamil, Luis Rodríguez; Mendez, Begoña Diaz; Gil, Patricio Suarez; Madera, Javier Mosquera

    2015-05-16

    To structure the rate of intraoperative complications that requires an intraoperative or perioperative resolution. We perform a literature review of Medline database. The research was focused on intraoperative laparoscopic procedures inside the field of urological oncology. General rate of perioperative complications in laparoscopic urologic surgery is described to be around 12.4%. Most of the manuscripts published do not make differences between pure intraoperative, intraoperative with postoperative consequences and postoperative complications. We expose a narrative statement of complications, possible solutions and possible preventions for most frequent retroperitoneal and pelvic laparoscopic surgery. We expose the results with the following order: retroperitoneal laparoscopic surgery (radical nephrectomy, partial nephrectomy, nephroureterectomy and adrenalectomy) and pelvic laparoscopic surgery (radical prostatectomy and radical cystectomy). Intraoperative complications vary from different series. More scheduled reports should be done in order to better understand the real rates of complications.

  18. Water-filled balloon in the postoperative resection cavity improves dose distribution to target volumes in radiotherapy of maxillary sinus carcinoma.

    PubMed

    Zhang, Qun; Lin, Shi-Rong; He, Fang; Kang, De-Hua; Chen, Guo-Zhang; Luo, Wei

    2011-11-01

    Postoperative radiotherapy is a major treatment for patients with maxillary sinus carcinoma. However, the irregular resection cavity poses a technical difficulty for this treatment, causing uneven dose distribution to target volumes. In this study, we evaluated the dose distribution to target volumes and normal tissues in postoperative intensity-modulated radiotherapy (IMRT) after placing a water-filled balloon into the resection cavity. Three postoperative patients with advanced maxillary sinus carcinoma were selected in this trial. Water-filled balloons and supporting dental stents were fabricated according to the size of the maxillary resection cavity. Simulation CT scans were performed with or without water-filled balloons, IMRT treatment plans were established, and dose distribution to target volumes and organs at risk were evaluated. Compared to those in the treatment plan without balloons, the dose (D98) delivered to 98% of the gross tumor volume (GTV) increased by 2.1 Gy (P = 0.009), homogeneity index (HI) improved by 2.3% (P = 0.001), and target volume conformity index (TCI) of 68 Gy increased by 18.5% (P = 0.011) in the plan with balloons. Dosimetry endpoints of normal tissues around target regions in both plans were not significantly different (P > 0.05) except for the optic chiasm. In the plan without balloons, 68 Gy high-dose regions did not entirely cover target volumes in the ethmoid sinus, posteromedial wall of the maxillary sinus, or surgical margin of the hard palate. In contrast, 68 Gy high-dose regions entirely covered the GTV in the plan with balloons. These results suggest that placing a water-filled balloon in the resection cavity for postoperative IMRT of maxillary sinus carcinoma can reduce low-dose regions and markedly and simultaneously increase dose homogeneity and conformity of target volumes.

  19. Tolerance of canine anastomoses to intraoperative radiation therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tepper, J.E.; Sindelar, W.; Travis, E.L.

    1983-07-01

    Radiation has been given intraoperatively to various abdominal structures in dogs, using a fixed horizontal 11 MeV electron beam at the Armed Forces Radiobiologic Research Institute. Animals were irradiated with single doses of 2000, 3000 and 4500 rad to a field which extended from the bifurcation of the aorta to the rib cage. All animals were irradiated during laparotomy under general anesthesia. Because the clinical use of intraoperative radiotherapy in cancer treatment will occasionally require irradiation of anastomosed large vessels and blind loops of bowel, the tolerance of aortic anastomoses and the suture lines of blind loops of jejunum tomore » irradiation were studied. Responses in these experiments were scored at times up to one year after irradiation. In separate experiments both aortic and intestinal anastomoses were performed on each animal for evaluation of short term response. The dogs with aortic anastomoses showed adequate healing at all doses with no evidence of suture line weakening. On long-term follow-up one animal (2000 rad) had stenosis at the anastomosis and one animal (4500 rad) developed an arteriovenous fistula. Three of the animals that had an intestinal blind loop irradiated subsequently developed intussusception, with the irradiated loop acting as the lead point. One week after irradiation, bursting pressure of an intestinal blind loop was normal at 3000 rad, but markedly decreased at 4500 rad. No late complications were noted after the irradiation of the intestinal anastomosis. No late complicatons were observed after irradiation of intestinal anastomoses, but one needs to be cautious with regards to possible late stenosis at the site of an irradiated vascular anastomosis.« less

  20. Validation of a personalized dosimetric evaluation tool (Oedipe) for targeted radiotherapy based on the Monte Carlo MCNPX code

    NASA Astrophysics Data System (ADS)

    Chiavassa, S.; Aubineau-Lanièce, I.; Bitar, A.; Lisbona, A.; Barbet, J.; Franck, D.; Jourdain, J. R.; Bardiès, M.

    2006-02-01

    Dosimetric studies are necessary for all patients treated with targeted radiotherapy. In order to attain the precision required, we have developed Oedipe, a dosimetric tool based on the MCNPX Monte Carlo code. The anatomy of each patient is considered in the form of a voxel-based geometry created using computed tomography (CT) images or magnetic resonance imaging (MRI). Oedipe enables dosimetry studies to be carried out at the voxel scale. Validation of the results obtained by comparison with existing methods is complex because there are multiple sources of variation: calculation methods (different Monte Carlo codes, point kernel), patient representations (model or specific) and geometry definitions (mathematical or voxel-based). In this paper, we validate Oedipe by taking each of these parameters into account independently. Monte Carlo methodology requires long calculation times, particularly in the case of voxel-based geometries, and this is one of the limits of personalized dosimetric methods. However, our results show that the use of voxel-based geometry as opposed to a mathematically defined geometry decreases the calculation time two-fold, due to an optimization of the MCNPX2.5e code. It is therefore possible to envisage the use of Oedipe for personalized dosimetry in the clinical context of targeted radiotherapy.

  1. Intraoperative laparoscopic complications for urological cancer procedures

    PubMed Central

    Montes, Sergio Fernández-Pello; Rodríguez, Ivan Gonzalez; Ugarteburu, Rodrigo Gil; Villamil, Luis Rodríguez; Mendez, Begoña Diaz; Gil, Patricio Suarez; Madera, Javier Mosquera

    2015-01-01

    AIM: To structure the rate of intraoperative complications that requires an intraoperative or perioperative resolution. METHODS: We perform a literature review of Medline database. The research was focused on intraoperative laparoscopic procedures inside the field of urological oncology. General rate of perioperative complications in laparoscopic urologic surgery is described to be around 12.4%. Most of the manuscripts published do not make differences between pure intraoperative, intraoperative with postoperative consequences and postoperative complications. RESULTS: We expose a narrative statement of complications, possible solutions and possible preventions for most frequent retroperitoneal and pelvic laparoscopic surgery. We expose the results with the following order: retroperitoneal laparoscopic surgery (radical nephrectomy, partial nephrectomy, nephroureterectomy and adrenalectomy) and pelvic laparoscopic surgery (radical prostatectomy and radical cystectomy). CONCLUSION: Intraoperative complications vary from different series. More scheduled reports should be done in order to better understand the real rates of complications. PMID:25984519

  2. Carbon-ion radiotherapy for marginal lymph node recurrences of cervical cancer after definitive radiotherapy: a case report.

    PubMed

    Tamaki, Tomoaki; Ohno, Tatsuya; Kiyohara, Hiroki; Noda, Shin-ei; Ohkubo, Yu; Ando, Ken; Wakatsuki, Masaru; Kato, Shingo; Kamada, Tadashi; Nakano, Takashi

    2013-04-05

    Recurrences of cervical cancer after definitive radiotherapy often occur at common iliac or para-aortic lymph nodes as marginal lymph node recurrences. Patients with these recurrences have a chance of long-term survival by optimal re-treatment with radiotherapy. However, the re-irradiation often overlaps the initial and the secondary radiotherapy fields and can result in increased normal tissue toxicities in the bowels or the stomach. Carbon-ion radiotherapy, a form of particle beam radiotherapy using accelerated carbon ions, offers more conformal and sharp dose distribution than X-ray radiotherapy. Therefore, this approach enables the delivery of high radiation doses to the target while sparing its surrounding normal tissues. Marginal lymph node recurrences in common iliac lymph nodes after radiotherapy were treated successfully by carbon-ion radiotherapy in two patients. These two patients were initially treated with a combination of external beam radiotherapy and intracavitary and interstitial brachytherapy. However, the diseases recurred in the lymph nodes near the border of the initial radiotherapy fields after 22 months and 23 months. Because re-irradiation with X-ray radiotherapy may deliver high doses to a section of the bowels, carbon-ion radiotherapy was selected to treat the lymph node recurrences. A total dose of 48 Gy (RBE) in 12 fractions over 3 weeks was given to the lymph node recurrences, and the tumors disappeared completely with no severe acute toxicities. The two patients showed no evidence of disease for 75 months and 63 months after the initial radiotherapy and for 50 months and 37 months after the carbon-ion radiotherapy, respectively. No severe late adverse effects are observed in these patients. The two presented cases suggest that the highly conformal dose distribution of carbon-ion radiotherapy may be beneficial in the treatment of marginal lymph node recurrences after radiotherapy. In addition, the higher biological effect of carbon

  3. The learning curve in short-stem THA: influence of the surgeon's experience on intraoperative adjustments due to intraoperative radiography.

    PubMed

    Loweg, Lennard; Kutzner, Karl Philipp; Trost, Matthias; Hechtner, Marlene; Drees, Philipp; Pfeil, Joachim; Schneider, Michael

    2018-02-01

    Short-stem THA has become increasingly popular over the last decade. However, implantation technique differs from conventional THA and thus possibly involves a distinct learning curve. The purpose of this study was to evaluate the value of intraoperative radiography and the influence of the surgeon's experience on intraoperative adjustments in short-stem THA. A total of 287 consecutive short-stem THAs, operated by a total of 24 senior consultants, consultants and residents in training, were prospectively included. Intraoperative radiography was performed after trial reduction. Preoperative planning and intraoperative outcome with regard to positioning, sizing of components as well as resulting offset and leg length were compared. Frequency, reason and type of intraoperative adjustments were documented in relation to the surgeon's experience. Operation time was assessed. One hundred and fifty-six (54.4%) procedures were carried out by one of three senior consultants, and a total of nine consultants and 12 residents in training performed 105 (36.6%) and 26 (9.0%) operations, respectively. In 121 cases (42.2%), intraoperative adjustments were made following intraoperative radiography. Intraoperative adjustments of one or more components were made by senior consultants in 51 cases (32.7%), by consultants in 53 cases (50.5%) and by residents in 17 cases (65.4%), respectively. The most common cause was undersizing of the stem. Operation time varied markedly between groups of surgeons. Short-stem THA involves a learning curve. Intraoperative radiography is decisive for prevention of malpositioning and undersizing of components, as well as loss of offset and leg length discrepancies. Hence, it should be considered mandatory, especially for less experienced surgeons.

  4. Perspectives in Intraoperative Diagnostics of Human Gliomas

    PubMed Central

    Tyurikova, O.; Dembitskaya, Y.; Yashin, K.; Mishchenko, M.; Vedunova, M.; Medyanik, I.; Kazantsev, V.

    2015-01-01

    Amongst large a variety of oncological diseases, malignant gliomas represent one of the most severe types of tumors. They are also the most common type of the brain tumors and account for over half of the astrocytic tumors. According to different sources, the average life expectancy of patients with various glioblastomas varies between 10 and 12 months and that of patients with anaplastic astrocytic tumors between 20 and 24 months. Therefore, studies of the physiology of transformed glial cells are critical for the development of treatment methods. Modern medical approaches offer complex procedures, including the microsurgical tumor removal, radiotherapy, and chemotherapy, supplemented with photodynamic therapy and immunotherapy. The most radical of them is surgical resection, which allows removing the largest part of the tumor, reduces the intracranial hypertension, and minimizes the degree of neurological deficit. However, complete removal of the tumor remains impossible. The main limitations are insufficient visualization of glioma boundaries, due to its infiltrative growth, and the necessity to preserve healthy tissue. This review is devoted to the description of advantages and disadvantages of modern intraoperative diagnostics of human gliomas and highlights potential perspectives for development of their treatment. PMID:26543495

  5. SU-E-T-412: Evaluation of Tungsten-Based Functional Paper for Attenuation Device in Intraoperative Radiotherapy for Breast Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kamomae, T; Monzen, H; Okudaira, K

    Purpose: Intraoperative radiotherapy (IORT) with an electron beam is one of the accelerated partial breast irradiation methods that have recently been used in early-stage breast cancer. A protective acrylic resin-copper disk is inserted between the breast tissue and the pectoralis muscle to minimize the dose received by the posterior structures. However, a problem with this protective disk is that the surgical incision must be larger than the field size because the disk is manufactured from stiff and unyielding materials. The purpose of this study was to assess the applicability of a new tungsten-based functional paper (TFP) as an alternative tomore » the existing protective disk in IORT. Methods: The newly introduced TFP (Toppan Printing Co., Ltd., Tokyo, JP) is anticipated to become a useful device that is lead-free, light, flexible, and easily processed. The radiation shielding performance of TFP was verified by experimental measurements and Monte Carlo (MC) simulations using PHITS code. The doses transmitted through the protective disk or TFP were measured on a Mobetron mobile accelerator. The same geometries were then reproduced, and the dose distributions were simulated by the MC method. Results: The percentages of transmitted dose relative to the absence of the existing protective disk were lower than 2% in both the measurements and MC simulations. In the experimental measurements, the percentages of transmitted dose for a 9 MeV electron beam were 48.1, 2.3, and 0.6% with TFP thicknesses of 1.9, 3.7, and 7.4 mm, respectively. The percentages for a 12 MeV were 76.0, 49.3, 20.0, and 5.5% with TFP thicknesses of 1.9, 3.7, 7.4, and 14.8 mm, respectively. The results of the MC simulation showed a slight dose increase at the incident surface of the TFP caused by backscattered radiation. Conclusion: The results indicate that a small-incision procedure may be possible by the use of TFP.« less

  6. Patterns of Radiotherapy Practice for Pancreatic Cancer in Japan: Results of the Japanese Radiation Oncology Study Group (JROSG) Survey

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ogawa, Kazuhiko, E-mail: kogawa@med.u-ryukyu.ac.j; Ito, Yoshinori; Karasawa, Katsuyuki

    2010-07-01

    Purpose: To determine the patterns of radiotherapy practice for pancreatic cancer in Japan. Methods and Materials: A questionnaire-based national survey of radiotherapy for pancreatic cancer treated between 2000 and 2006 was conducted by the Japanese Radiation Oncology Study Group (JROSG). Detailed information on 870 patients from 34 radiation oncology institutions was accumulated. Results: The median age of all patients was 64 years (range, 36-88), and 80.2% of the patients had good performance status. More than 85% of patients had clinical Stage T3-T4 disease, and 68.9% of patients had unresectable disease at diagnosis. Concerning radiotherapy (RT), 49.8% of patients were treatedmore » with radical external beam RT (EBRT) (median dose, 50.4 Gy), 44.4% of patients were treated with intraoperative RT (median dose, 25 Gy) with or without EBRT (median dose, 45 Gy), and 5.9% of patients were treated with postoperative radiotherapy (median dose, 50 Gy). The treatment field consisted of the primary tumor (bed) only in 55.6% of the patients. Computed tomography-based treatment planning and conformal RT was used in 93.1% and 83.1% of the patients treated with EBRT, respectively. Chemotherapy was used for 691 patients (79.4%; before RT for 66 patients; during RT for 531; and after RT for 364). Gemcitabine was the most frequently used drug, followed by 5-fluorouracil. Conclusion: This study describes the general patterns of RT practice for pancreatic cancer in Japan. Most patients had advanced unresectable disease, and radical EBRT, as well as intraoperative RT with or without EBRT, was frequently used. Chemotherapy with gemcitabine was commonly used in conjunction with RT during the survey period.« less

  7. Intraoperative tight glucose control using hyperinsulinemic normoglycemia increases delirium after cardiac surgery.

    PubMed

    Saager, Leif; Duncan, Andra E; Yared, Jean-Pierre; Hesler, Brian D; You, Jing; Deogaonkar, Anupa; Sessler, Daniel I; Kurz, Andrea

    2015-06-01

    Postoperative delirium is common in patients recovering from cardiac surgery. Tight glucose control has been shown to reduce mortality and morbidity. Therefore, the authors sought to determine the effect of tight intraoperative glucose control using a hyperinsulinemic-normoglycemic clamp approach on postoperative delirium in patients undergoing cardiac surgery. The authors enrolled 198 adult patients having cardiac surgery in this randomized, double-blind, single-center trial. Patients were randomly assigned to either tight intraoperative glucose control with a hyperinsulinemic-normoglycemic clamp (target blood glucose, 80 to 110 mg/dl) or standard therapy (conventional insulin administration with blood glucose target, <150 mg/dl). Delirium was assessed using a comprehensive delirium battery. The authors considered patients to have experienced postoperative delirium when Confusion Assessment Method testing was positive at any assessment. A positive Confusion Assessment Method was defined by the presence of features 1 (acute onset and fluctuating course) and 2 (inattention) and either 3 (disorganized thinking) or 4 (altered consciousness). Patients randomized to tight glucose control were more likely to be diagnosed as being delirious than those assigned to routine glucose control (26 of 93 vs. 15 of 105; relative risk, 1.89; 95% CI, 1.06 to 3.37; P = 0.03), after adjusting for preoperative usage of calcium channel blocker and American Society of Anesthesiologist physical status. Delirium severity, among patients with delirium, was comparable with each glucose management strategy. Intraoperative hyperinsulinemic-normoglycemia augments the risk of delirium after cardiac surgery, but not its severity.

  8. Measurement of radiation dose with BeO dosimeters using optically stimulated luminescence technique in radiotherapy applications.

    PubMed

    Şahin, Serdar; Güneş Tanır, A; Meriç, Niyazi; Aydınkarahaliloğlu, Ercan

    2015-09-01

    The radiation dose delivered to the target by using different radiotherapy applications has been measured with the help of beryllium oxide (BeO) dosimeters to be placed inside the rando phantom. Three-Dimensional Conformal Radiotherapy (3DCRT), Intensity-Modulated Radiotherapy (IMRT) and Intensity-Modulated Arc Therapy (IMAT) have been used as radiotherapy application. Individual treatment plans have been made for the three radiotherapy applications of rando phantom. The section 4 on the phantom was selected as target and 200 cGy doses were delivered. After the dosimeters placed on section 4 (target) and the sections 2 and 6 (non-target) were irradiated, the result was read through the OSL technique on the Risø TL/OSL system. This procedure was repeated three times for each radiotherapy application. The doses delivered to the target and the non-target sections as a result of the 3DCRT, IMRT and IMAT plans were analyzed. The doses received by the target were measured as 204.71 cGy, 204.76 cGy and 205.65 cGy, respectively. The dose values obtained from treatment planning system (TPS) were compared to the dose values obtained using the OSL technique. It has been concluded that, the radiation dose can be measured with the OSL technique by using BeO dosimeters in medical practices. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Safety, efficacy, and cost of intraoperative indocyanine green angiography compared to intraoperative catheter angiography in cerebral aneurysm surgery.

    PubMed

    Hardesty, Douglas A; Thind, Harjot; Zabramski, Joseph M; Spetzler, Robert F; Nakaji, Peter

    2014-08-01

    Intraoperative angiography in cerebrovascular neurosurgery can drive the repositioning or addition of aneurysm clips. Our institution has switched from a strategy of intraoperative digital subtraction angiography (DSA) universally, to a strategy of indocyanine green (ICG) videoangiography with DSA on an as-needed basis. We retrospectively evaluated whether the rates of perioperative stroke, unexpected postoperative aneurysm residual, or parent vessel stenosis differed in 100 patients from each era (2002, "DSA era"; 2007, "ICG era"). The clip repositioning rate for neck residual or parent vessel stenosis did not differ significantly between the two eras. There were no differences in the rate of perioperative stroke or rate of false-negative studies. The per-patient cost of intraoperative imaging within the DSA era was significantly higher than in the ICG era. The replacement of routine intraoperative DSA with ICG videoangiography and selective intraoperative DSA in cerebrovascular aneurysm surgery is safe and effective. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  10. [Target volume margins for lung cancer: internal target volume/clinical target volume].

    PubMed

    Jouin, A; Pourel, N

    2013-10-01

    The aim of this study was to carry out a review of margins that should be used for the delineation of target volumes in lung cancer, with a focus on margins from gross tumour volume (GTV) to clinical target volume (CTV) and internal target volume (ITV) delineation. Our review was based on a PubMed literature search with, as a cornerstone, the 2010 European Organisation for Research and Treatment of Cancer (EORTC) recommandations by De Ruysscher et al. The keywords used for the search were: radiotherapy, lung cancer, clinical target volume, internal target volume. The relevant information was categorized under the following headings: gross tumour volume definition (GTV), CTV-GTV margin (first tumoural CTV then nodal CTV definition), in field versus elective nodal irradiation, metabolic imaging role through the input of the PET scanner for tumour target volume and limitations of PET-CT imaging for nodal target volume definition, postoperative radiotherapy target volume definition, delineation of target volumes after induction chemotherapy; then the internal target volume is specified as well as tumoural mobility for lung cancer and respiratory gating techniques. Finally, a chapter is dedicated to planning target volume definition and another to small cell lung cancer. For each heading, the most relevant and recent clinical trials and publications are mentioned. Copyright © 2013. Published by Elsevier SAS.

  11. Intraoperative ultrasound in colorectal surgery.

    PubMed

    Greif, Franklin; Aranovich, David; Hananel, Nissim; Knizhnik, Mikhail; Belenky, Alexander

    2009-09-01

    To assess the accuracy of intraoperative ultrasound (IOUS) as a localizing technique for colorectal resections, and its impact on surgical management. Twenty-five patients (15 men and 10 women; mean age, 74.4 years) with early cancers (p T1), or polyps, not amenable to endoscopic removal were selected. IOUS was used as a sole method of intraoperative localization. Its performance was evaluated through review of preoperative colonoscopy reports, intraoperative findings, histopathology reports, and clinical follow-up. The lesions were situated in the cecum (n = 5), ascending colon (n = 3), transverse colon (n = 4), descending colon (n = 7), and rectum (n = 6). IOUS technique allowed correct localization in 24 of 25 patients, visualization of the bowel wall, and its penetration by malignant tumors. In rectal lesions, IOUS showed clearly the tumor and its margin, which facilitated performance sphincter-sparing procedure. In patients with small polyps and early cancers of colon and rectum, IOUS may be effectively used as a sole method of intraoperative localization and provide additional information that may alter decision making with regard to surgical technique. (c) 2009 Wiley Periodicals, Inc.

  12. Predictors of intraoperative hypotension and bradycardia.

    PubMed

    Cheung, Christopher C; Martyn, Alan; Campbell, Norman; Frost, Shaun; Gilbert, Kenneth; Michota, Franklin; Seal, Douglas; Ghali, William; Khan, Nadia A

    2015-05-01

    Perioperative hypotension and bradycardia in the surgical patient are associated with adverse outcomes, including stroke. We developed and evaluated a new preoperative risk model in predicting intraoperative hypotension or bradycardia in patients undergoing elective noncardiac surgery. Prospective data were collected in 193 patients undergoing elective, noncardiac surgery. Intraoperative hypotension was defined as systolic blood pressure <90 mm Hg for >5 minutes or a 35% decrease in the mean arterial blood pressure. Intraoperative bradycardia was defined as a heart rate of <60 beats/min for >5 minutes. A logistic regression model was developed for predicting intraoperative hypotension or bradycardia with bootstrap validation. Model performance was assessed using area under the receiver operating curves and Hosmer-Lemeshow tests. A total of 127 patients developed hypotension or bradycardia. The average age of participants was 67.6 ± 11.3 years, and 59.1% underwent major surgery. A final 5-item score was developed, including preoperative Heart rate (<60 beats/min), preoperative hypotension (<110/60 mm Hg), Elderly age (>65 years), preoperative renin-Angiotensin blockade (angiotensin-converting enzyme inhibitors, angiotensin receptor blockers, or beta-blockers), Revised cardiac risk index (≥3 points), and Type of surgery (major surgery), entitled the "HEART" score. The HEART score was moderately predictive of intraoperative bradycardia or hypotension (odds ratio, 2.51; 95% confidence interval, 1.79-3.53; C-statistic, 0.75). Maximum points on the HEART score were associated with an increased likelihood ratio for intraoperative bradycardia or hypotension (likelihood ratio, +3.64). The 5-point HEART score was predictive of intraoperative hypotension or bradycardia. These findings suggest a role for using the HEART score to better risk-stratify patients preoperatively and may help guide decisions on perioperative management of blood pressure and heart rate

  13. Clinical experience with image-guided radiotherapy in an accelerated partial breast intensity-modulated radiotherapy protocol.

    PubMed

    Leonard, Charles E; Tallhamer, Michael; Johnson, Tim; Hunter, Kari; Howell, Kathryn; Kercher, Jane; Widener, Jodi; Kaske, Terese; Paul, Devchand; Sedlacek, Scot; Carter, Dennis L

    2010-02-01

    To explore the feasibility of fiducial markers for the use of image-guided radiotherapy (IGRT) in an accelerated partial breast intensity modulated radiotherapy protocol. Nineteen patients consented to an institutional review board approved protocol of accelerated partial breast intensity-modulated radiotherapy with fiducial marker placement and treatment with IGRT. Patients (1 patient with bilateral breast cancer; 20 total breasts) underwent ultrasound guided implantation of three 1.2- x 3-mm gold markers placed around the surgical cavity. For each patient, table shifts (inferior/superior, right/left lateral, and anterior/posterior) and minimum, maximum, mean error with standard deviation were recorded for each of the 10 BID treatments. The dose contribution of daily orthogonal films was also examined. All IGRT patients underwent successful marker placement. In all, 200 IGRT treatment sessions were performed. The average vector displacement was 4 mm (range, 2-7 mm). The average superior/inferior shift was 2 mm (range, 0-5 mm), the average lateral shift was 2 mm (range, 1-4 mm), and the average anterior/posterior shift was 3 mm (range, 1 5 mm). This study shows that the use of IGRT can be successfully used in an accelerated partial breast intensity-modulated radiotherapy protocol. The authors believe that this technique has increased daily treatment accuracy and permitted reduction in the margin added to the clinical target volume to form the planning target volume. Copyright 2010 Elsevier Inc. All rights reserved.

  14. Intraoperative MR-guided DBS implantation for treating PD and ET

    NASA Astrophysics Data System (ADS)

    Liu, Haiying; Maxwell, Robert E.; Truwit, Charles L.

    2001-05-01

    Deep brain stimulator (DBS) implantation is a promising treatment alternative for suppressing the motor tremor symptoms in Parkinson disease (PD) patient. The main objective is to develop a minimally invasive approach using high spatial resolution and soft-tissue contrast MR imaging techniques to guide the surgical placement of DBS. In the MR-guided procedure, the high spatial resolution MR images were obtained intra-operatively and used to target stereotactically a specific deep brain location. The neurosurgery for craniotomy was performed in the front of the magnet outside of the 10 Gauss line. Aided with positional registration assembly for the stereotactic head frame, the target location (VIM or GPi or STN) in deep brain areas was identified and measured from the MR images in reference to the markers in the calibration assembly of the head frame before the burrhole prep. In 20 patients, MR- guided DBS implantations have been performed according to the new methodology. MR-guided DBS implantation at high magnetic field strength has been shown to be feasible and desirable. In addition to the improved outcome, this offers a new surgical approach in which intra-operative visualization is possible during intervention, and any complications such as bleeding can be assessed in situ immediately prior to dural closure.

  15. Intraoperative optical coherence tomography: past, present, and future

    PubMed Central

    Ehlers, J P

    2016-01-01

    To provide an overview of the current state of intraoperative optical coherence tomography (OCT). Literature review of studies pertaining to intraoperative OCT examining both the technology aspects of the imaging platform and the current evidence for patient care. Over the last several years, there have been significant advances in integrative technology for intraoperative OCT. This has resulted in the development of multiple microscope-integrated systems and a rapidly expanding field of image-guided surgical care. Multiple studies have demonstrated the potential role for intraoperative OCT in facilitating surgeon understanding of the surgical environment, tissue configuration, and overall changes to anatomy. In fact, the PIONEER and DISCOVER studies, both demonstrated a potential significant percentage of cases that intraoperative OCT alters surgical decision-making in both anterior and posterior segment surgery. Current areas of exploration and development include OCT-compatible instrumentation, automated tracking, intraoperative OCT software platforms, and surgeon feedback/visualization platforms. Intraoperative OCT is an emerging technology that holds promise for enhancing the surgical care of both anterior segment and posterior segment conditions. Hurdles remain for adoption and widespread utilization, including cost, optimized feedback platforms, and more definitive value for individualized surgical care with image guidance. PMID:26681147

  16. Use of Maximum Intensity Projections (MIPs) for target outlining in 4DCT radiotherapy planning.

    PubMed

    Muirhead, Rebecca; McNee, Stuart G; Featherstone, Carrie; Moore, Karen; Muscat, Sarah

    2008-12-01

    Four-dimensional computed tomography (4DCT) is currently being introduced to radiotherapy centers worldwide, for use in radical radiotherapy planning for non-small cell lung cancer (NSCLC). A significant drawback is the time required to delineate 10 individual CT scans for each patient. Every department will hence ask the question if the single Maximum Intensity Projection (MIP) scan can be used as an alternative. Although the problems regarding the use of the MIP in node-positive disease have been discussed in the literature, a comprehensive study assessing its use has not been published. We compared an internal target volume (ITV) created using the MIP to an ITV created from the composite volume of 10 clinical target volumes (CTVs) delineated on the 10 phases of the 4DCT. 4DCT data was collected from 14 patients with NSCLC. In each patient, the ITV was delineated on the MIP image (ITV_MIP) and a composite ITV created from the 10 CTVs delineated on each of the 10 scans in the dataset. The structures were compared by assessment of volumes of overlap and exclusion. There was a median of 19.0% (range, 5.5-35.4%) of the volume of ITV_10phase not enclosed by the ITV_MIP, demonstrating that the use of the MIP could result in under-treatment of disease. In contrast only a very small amount of the ITV_MIP was not enclosed by the ITV_10phase (median of 2.3%, range, 0.4-9.8%), indicating the ITV_10phase covers almost all of the tumor tissue as identified by MIP. Although there were only two Stage I patients, both demonstrated very similar ITV_10phase and ITV_MIP volumes. These findings suggest that Stage I NSCLC tumors could be outlined on the MIP alone. In Stage II and III tumors the ITV_10phase would be more reliable. To prevent under-treatment of disease, the MIP image can only be used for delineation in Stage I tumors.

  17. Placement of empty catheters for an HDR-emulating LDR prostate brachytherapy technique: comparison to standard intraoperative planning.

    PubMed

    Niedermayr, Thomas R; Nguyen, Paul L; Murciano-Goroff, Yonina R; Kovtun, Konstantin A; Neubauer Sugar, Emily; Cail, Daniel W; O'Farrell, Desmond A; Hansen, Jorgen L; Cormack, Robert A; Buzurovic, Ivan; Wolfsberger, Luciant T; O'Leary, Michael P; Steele, Graeme S; Devlin, Philip M; Orio, Peter F

    2014-01-01

    We sought to determine whether placing empty catheters within the prostate and then inverse planning iodine-125 seed locations within those catheters (High Dose Rate-Emulating Low Dose Rate Prostate Brachytherapy [HELP] technique) would improve concordance between planned and achieved dosimetry compared with a standard intraoperative technique. We examined 30 consecutive low dose rate prostate cases performed by standard intraoperative technique of planning followed by needle placement/seed deposition and compared them to 30 consecutive low dose rate prostate cases performed by the HELP technique. The primary endpoint was concordance between planned percentage of the clinical target volume that receives at least 100% of the prescribed dose/dose that covers 90% of the volume of the clinical target volume (V100/D90) and the actual V100/D90 achieved at Postoperative Day 1. The HELP technique had superior concordance between the planned target dosimetry and what was actually achieved at Day 1 and Day 30. Specifically, target D90 at Day 1 was on average 33.7 Gy less than planned for the standard intraoperative technique but was only 10.5 Gy less than planned for the HELP technique (p < 0.001). Day 30 values were 16.6 Gy less vs. 2.2 Gy more than planned, respectively (p = 0.028). Day 1 target V100 was 6.3% less than planned with standard vs. 2.8% less for HELP (p < 0.001). There was no significant difference between the urethral and rectal concordance (all p > 0.05). Placing empty needles first and optimizing the plan to the known positions of the needles resulted in improved concordance between the planned and the achieved dosimetry to the target, possibly because of elimination of errors in needle placement. Copyright © 2014 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  18. Intraoperative detection and elimination of microscopic tumors in head and neck (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Lukianova-Hleb, Ekaterina Y.; Kim, Yoo-Shin; Belatsarkouski, Ihar; Hanna, Ehab Y.; Gillenwater, Ann M.; O'Neill, Brian; Lapotko, Dmitri

    2016-02-01

    Failure of cancer surgery to intraoperatively detect and eliminate microscopic residual disease (MRD) causes lethal recurrence and metastases, whereas removal of important normal tissues causes excessive morbidity. We report plasmonic nanobubble (PNB) surgical technology to intraoperatively detect and eliminate MRD in surgical bed. PNBs were generated in vivo in head and neck cancer cells by systemically targeting tumor with gold colloids and locally-applied near-infrared low energy short laser pulse, and were simultaneously detected with acoustic probe. In mouse models of head and neck squamous cell carcinoma, single cancer cells and MRD (undetectable with standard histological methods) were instantaneously non-invasively detected in solid tissue in surgical bed. In resectable MRD, PNB-guided surgery prevented local recurrence and delivered 100% tumor-free survival. In unresectable MRD, PNB nano-surgery improved survival by two-fold compared to standard surgery. PNB metrics correlated with the tumor recurrence rate. PNB surgical technology precisely detects and immediately eliminates MRD at macro- and micro-scale in a simple and safe intraoperative procedure.

  19. Contribution of FDOPA PET to radiotherapy planning for advanced glioma

    NASA Astrophysics Data System (ADS)

    Dowson, Nicholas; Fay, Michael; Thomas, Paul; Jeffree, Rosalind; McDowall, Robert; Winter, Craig; Coulthard, Alan; Smith, Jye; Gal, Yaniv; Bourgeat, Pierrick; Salvado, Olivier; Crozier, Stuart; Rose, Stephen

    2014-03-01

    Despite radical treatment with surgery, radiotherapy and chemotherapy, advanced gliomas recur within months. Geographic misses in radiotherapy planning may play a role in this seemingly ineluctable recurrence. Planning is typically performed on post-contrast MRIs, which are known to underreport tumour volume relative to FDOPA PET scans. FDOPA PET fused with contrast enhanced MRI has demonstrated greater sensitivity and specificity than MRI alone. One sign of potential misses would be differences between gross target volumes (GTVs) defined using MRI alone and when fused with PET. This work examined whether such a discrepancy may occur. Materials and Methods: For six patients, a 75 minute PET scan using 3,4-dihydroxy-6-18F-fluoro-L-phynel-alanine (18F-FDOPA) was taken within 2 days of gadolinium enhanced MRI scans. In addition to standard radiotherapy planning by an experienced radiotherapy oncologist, a second gross target volume (GTV) was defined by an experienced nuclear medicine specialist for fused PET and MRI, while blinded to the radiotherapy plans. The volumes from standard radiotherapy planning were compared to the PET defined GTV. Results: The comparison indicated radiotherapy planning would change in several cases if FDOPA PET data was available. PET-defined contours were external to 95% prescribed dose for several patients. However, due to the radiotherapy margins, the discrepancies were relatively small in size and all received a dose of 50 Gray or more. Conclusions: Given the limited size of the discrepancies it is uncertain that geographic misses played a major role in patient outcome. Even so, the existence of discrepancies indicates that FDOPA PET could assist in better defining margins when planning radiotherapy for advanced glioma, which could be important for highly conformal radiotherapy plans.

  20. Intraoperative cranial nerve monitoring.

    PubMed

    Harper, C Michel

    2004-03-01

    The purpose of intraoperative monitoring is to preserve function and prevent injury to the nervous system at a time when clinical examination is not possible. Cranial nerves are delicate structures and are susceptible to damage by mechanical trauma or ischemia during intracranial and extracranial surgery. A number of reliable electrodiagnostic techniques, including nerve conduction studies, electromyography, and the recording of evoked potentials have been adapted to the study of cranial nerve function during surgery. A growing body of evidence supports the utility of intraoperative monitoring of cranial nerve nerves during selected surgical procedures.

  1. SU-E-T-495: Influence of Reduced Target-To-Nozzle Distance On Secondary Neutron Dose Equivalent in Proton and Carbon Ion Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheng, Y; Shahnazi, K; Wang, W

    Purpose: Ion beams have an unavoidable lateral spread due to nuclear interactions interacting with the air and monitoring systems. To minimize this spread, the distance between the nozzle and the patient should be kept as small as possible.The purpose of this work was to determine the impact of the target-to-nozzle distance reduction on the secondary neutron dose equivalent in proton and carbon ion radiotherapy. Methods: In this study, abdominal and head phantoms were scanned with our CT scanner. Cubical targets with side lengths of 3 cm to 10 cm and 1 cm to 5 cm were drawn in the abdominalmore » and head phantoms respectively. Two intensity-modulated plans were made for each phantom and ion. The first of these plans placed the target at the isocenter while the other shifted the phantom 30 cm towards the nozzle. The plans at both phantom locations were optimized to provide identical dose coverage to the PTVs.Secondary neutron dose equivalent at 50 cm lateral to the center of target. Results: The neutron dose equivalent was higher for the larger field size from 0.25µSv per Gy (RBE) to 72µSv per Gy (RBE). The neutron dose equivalent was smaller when the phantom was placed at the upstream target location versus at the isocenter location by 8.9% to 10.4% and 11.0% to 22.1% for proton plans of the abdominal and head phantoms respectively. Differences for carbon plans with different target-to-nozzle locations were less than 3% for both phantoms. Conclusion: A reduction of target-to-nozzle distance can lead to benefits for proton radiotherapy. In this study, a reduction of secondary neutron dose equivalent was found for proton plans with a smaller target-to-nozzle distance. A greater impact was found for a head phantom with a smaller field size; however, a reduction of the target-to-nozzle distance had little effect for carbon therapy.« less

  2. Intra-operative characterisation of subthalamic oscillations in Parkinson’s disease

    PubMed Central

    Geng, Xinyi; Xu, Xin; Horn, Andreas; Li, Ningfei; Ling, Zhipei; Brown, Peter; Wang, Shouyan

    2018-01-01

    Objective This study aims to use the activities recorded directly from the deep brain stimulation (DBS) electrode to address the focality and distinct nature of the local field potential (LFP) activities of different frequency. Methods Pre-operative and intra-operative magnetic resonance imaging (MRI) were acquired from patients with Parkinson’s disease (PD) who underwent DBS in the subthalamic nucleus and intra-operative LFP recording at rest and during cued movements. Images were reconstructed and 3-D visualized using Lead-DBS® toolbox to determine the coordinates of contact. The resting spectral power and movement-related power modulation of LFP oscillations were estimated. Results Both subthalamic LFP activity recorded at rest and its modulation by movement had focal maxima in the alpha, beta and gamma bands. The spatial distribution of alpha band activity and its modulation was significantly different to that in the beta band. Moreover, there were significant differences in the scale and timing of movement related modulation across the frequency bands. Conclusion Subthalamic LFP activities within specific frequency bands can be distinguished by spatial topography and pattern of movement related modulation. Significance Assessment of the frequency, focality and pattern of movement related modulation of subthalamic LFPs reveals a heterogeneity of neural population activity in this region. This could potentially be leveraged to finesse intra-operative targeting and post-operative contact selection. PMID:29567582

  3. 135La as an Auger-electron emitter for targeted internal radiotherapy

    NASA Astrophysics Data System (ADS)

    Fonslet, J.; Lee, B. Q.; Tran, T. A.; Siragusa, M.; Jensen, M.; Kibédi, T.; E Stuchbery, A.; Severin, G. W.

    2018-01-01

    135La has favorable nuclear and chemical properties for Auger-based targeted internal radiotherapy. Here we present detailed investigations of the production, emissions, and dosimetry related to 135La therapy. 135La was produced by 16.5 MeV proton irradiation of metallic natBa on a medical cyclotron, and was isolated and purified by trap-and-release on weak cation-exchange resin. The average production rate was 407  ±  19 MBq µA-1 (saturation activity), and the radionuclidic purity was 98% at 20 h post irradiation. Chemical separation recovered  >  98 % of the 135La with an effective molar activity of 70  ±  20 GBq µmol-1. To better assess cellular and organ dosimetry of this nuclide, we have calculated the x-ray and Auger emission spectra using a Monte Carlo model accounting for effects of multiple vacancies during the Auger cascade. The generated Auger spectrum was used to calculate cellular S-factors. 135La was produced with high specific activity, reactivity, radionuclidic purity, and yield. The emission spectrum and the dosimetry are favorable for internal radionuclide therapy.

  4. The Effect of Intraoperative Hypothermia on Shoulder Arthroplasty.

    PubMed

    Jildeh, Toufic R; Okoroha, Kelechi R; Marshall, Nathan E; Amato, Chad; Trafton, Hunter; Muh, Stephanie J; Kolowich, Patricia

    2018-05-16

    Limited evidence is available regarding the correlation between intraoperative hypothermia and perioperative complications in shoulder arthroplasty. The purpose of this study was to determine the incidence of intraoperative hypothermia in patients treated with shoulder arthroplasty and its effect on perioperative complications. A retrospective chart review was performed on 657 consecutive patients who underwent shoulder arthroplasty at a single institution between August 2013 and June 2016. Demographic data, surgery-specific data, postoperative complications, length of stay, and 30-day read-mission were recorded. Patients were classified as hypothermic if their mean intraoperative temperature was less than 36°C. Statistical analyses with univariate and multivariate logistic regression were performed to evaluate the association of intraoperative hypothermia with perioperative complications. The incidence of intraoperative hypothermia in shoulder arthroplasty was 52.7%. Increasing age (P=.002), lower body mass index (P=.006), interscalene anesthetic (P=.004), and lower white blood cell count (P<.001) demonstrated increased association with hypothermia. Longer operating room times and increased estimated blood loss were not found to be associated with intraoperative hypothermia. Hypothermia demonstrated no significant association with surgical site infections nor any other perioperative complications. Patients undergoing shoulder arthroplasty showed a high incidence of intraoperative hypothermia. Lower body mass index, increasing age, interscalene anesthetic, and lower white blood cell count were associated with an increased incidence of hypothermia. Contrary to previous studies, intraoperative hypothermia was not found to contribute to perioperative complications in shoulder arthroplasty. [Orthopedics. 201x; xx(x):xx-xx.]. Copyright 2018, SLACK Incorporated.

  5. Poster - 36: Effect of Planning Target Volume Coverage on the Dose Delivered in Lung Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dekker, Chris; Wierzbicki, Marcin

    2016-08-15

    Purpose: In lung radiotherapy, breathing motion may be encompassed by contouring the internal target volume (ITV). Remaining uncertainties are included in a geometrical expansion to the planning target volume (PTV). In IMRT, the treatment is then optimized until a desired PTV fraction is covered by the appropriate dose. The resulting beams often carry high fluence in the PTV margin to overcome low lung density and to generate steep dose gradients. During treatment, the high density tumour can enter the PTV margin, potentially increasing target dose. Thus, planning lung IMRT with a reduced PTV dose may still achieve the desired ITVmore » dose during treatment. Methods: A retrospective analysis was carried out with 25 IMRT plans prescribed to 63 Gy in 30 fractions. The plans were re-normalized to cover various fractions of the PTV by different isodose lines. For each case, the isocentre was moved using 125 shifts derived from all 3D combinations of 0 mm, (PTV margin - 1 mm), and PTV margin. After each shift, the dose was recomputed to approximate the delivered dose. Results and Conclusion: Our plans typically cover 95% of the PTV by 95% of the dose. Reducing the PTV covered to 94% did not significantly reduce the delivered ITV doses for (PTV margin - 1 mm) shifts. Target doses were reduced significantly for all other shifts and planning goals studied. Thus, a reduced planning goal will likely deliver the desired target dose as long as the ITV rarely enters the last mm of the PTV margin.« less

  6. New Language and Old Problems in Breast Cancer Radiotherapy.

    PubMed

    Chiricuţă, Ion Christian

    2017-01-01

    New developments in breast cancer radiotherapy make possible new standards in treatment recommandations based on international guidelines. Developments in radiotherapy irradiation techniques from 2D to 3D-Conformal RT and to IMRT (Intensity Modulated Arc Therapy) make possible to reduce the usual side effects on the organs at risk as: skin, lung, miocard, bone, esophagus and brahial plexus. Dispite of all these progresses acute and late side effects are present. Side effects are as old as the radiotherapy was used. New solutions are available now by improving irradiation techniques. New techniques as sentinel node procedure (SNP) or partial breast irradiation (PBRT) and immediate breast reconstruction with silicon implants (IBRIS) make necessary new considerations regarding the target volume delineations. A new language for definition of gross tumor volume (GTV), clinical target volume (CTV) based on the new diagnostic methods as PET/CT,nonaparticle MRI will have real impact on target delineation and irradiation techniques. "The new common language in breast cancer therapy" would be the first step to improve the endresults and finally the quality of life of the patients. Celsius.

  7. Recent Advances in Image-Guided Radiotherapy for Head and Neck Carcinoma

    PubMed Central

    Nath, Sameer K.; Simpson, Daniel R.; Rose, Brent S.; Sandhu, Ajay P.

    2009-01-01

    Radiotherapy has a well-established role in the management of head and neck cancers. Over the past decade, a variety of new imaging modalities have been incorporated into the radiotherapy planning and delivery process. These technologies are collectively referred to as image-guided radiotherapy and may lead to significant gains in tumor control and radiation side effect profiles. In the following review, these techniques as they are applied to head and neck cancer patients are described, and clinical studies analyzing their use in target delineation, patient positioning, and adaptive radiotherapy are highlighted. Finally, we conclude with a brief discussion of potential areas of further radiotherapy advancement. PMID:19644564

  8. Radiobiological concepts for treatment planning of schemes that combines external beam radiotherapy and systemic targeted radiotherapy

    NASA Astrophysics Data System (ADS)

    Fabián Calderón Marín, Carlos; González González, Joaquín Jorge; Laguardia, Rodolfo Alfonso

    2017-09-01

    The combination of radiotherapy modalities with external bundles and systemic radiotherapy (CIERT) could be a reliable alternative for patients with multiple lesions or those where treatment planning maybe difficult because organ(s)-at-risk (OARs) constraints. Radiobiological models should have the capacity for predicting the biological irradiation response considering the differences in the temporal pattern of dose delivering in both modalities. Two CIERT scenarios were studied: sequential combination in which one modality is executed following the other one and concurrent combination when both modalities are running simultaneously. Expressions are provided for calculation of the dose-response magnitudes Tumor Control Probability (TCP) and Normal Tissue Complication Probability (NTCP). General results on radiobiological modeling using the linear-quadratic (LQ) model are also discussed. Inter-subject variation of radiosensitivity and volume irradiation effect in CIERT are studied. OARs should be under control during the planning in concurrent CIERT treatment as the administered activity is increased. The formulation presented here may be used for biological evaluation of prescriptions and biological treatment planning of CIERT schemes in clinical situation.

  9. Radiomics based targeted radiotherapy planning (Rad-TRaP): a computational framework for prostate cancer treatment planning with MRI.

    PubMed

    Shiradkar, Rakesh; Podder, Tarun K; Algohary, Ahmad; Viswanath, Satish; Ellis, Rodney J; Madabhushi, Anant

    2016-11-10

    Radiomics or computer - extracted texture features have been shown to achieve superior performance than multiparametric MRI (mpMRI) signal intensities alone in targeting prostate cancer (PCa) lesions. Radiomics along with deformable co-registration tools can be used to develop a framework to generate targeted focal radiotherapy treatment plans. The Rad-TRaP framework comprises three distinct modules. Firstly, a module for radiomics based detection of PCa lesions on mpMRI via a feature enabled machine learning classifier. The second module comprises a multi-modal deformable co-registration scheme to map tissue, organ, and delineated target volumes from MRI onto CT. Finally, the third module involves generation of a radiomics based dose plan on MRI for brachytherapy and on CT for EBRT using the target delineations transferred from the MRI to the CT. Rad-TRaP framework was evaluated using a retrospective cohort of 23 patient studies from two different institutions. 11 patients from the first institution were used to train a radiomics classifier, which was used to detect tumor regions in 12 patients from the second institution. The ground truth cancer delineations for training the machine learning classifier were made by an experienced radiation oncologist using mpMRI, knowledge of biopsy location and radiology reports. The detected tumor regions were used to generate treatment plans for brachytherapy using mpMRI, and tumor regions mapped from MRI to CT to generate corresponding treatment plans for EBRT. For each of EBRT and brachytherapy, 3 dose plans were generated - whole gland homogeneous ([Formula: see text]) which is the current clinical standard, radiomics based focal ([Formula: see text]), and whole gland with a radiomics based focal boost ([Formula: see text]). Comparison of [Formula: see text] against conventional [Formula: see text] revealed that targeted focal brachytherapy would result in a marked reduction in dosage to the OARs while ensuring that the

  10. Intraoperative endovascular ultrasonography

    NASA Astrophysics Data System (ADS)

    Eton, Darwin; Ahn, Samuel S.; Baker, J. D.; Pensabene, Joseph; Yeatman, Lawrence S.; Moore, Wesley S.

    1991-05-01

    The early experience using intra-operative endovascular ultrasonography (EU) is reported in eight patients undergoing lower extremity revasularization. In four patients, intra-operative EU successfully characterized inflow stenoses that were inadequately imaged with pre- operative arteriography. Two patients were found to have hemodynamically significant inflow stenoses, and were treated with intra-operative balloon angioplasty followed by repeat EU. The other two patients were found to have non-hemodynamically significant inflow stenoses requiring no treatment. Additional outflow procedures were required in all four patients. In the remaining four patients, EU was used to evaluate the completeness of TEC rotary atherectomy, of Hall oscillatory endarterectomy, of thrombectomy of the superficial femoral and popliteal arteries, and of valve lysis during in situ saphenous vein grafting, respectively. In the latter case, the valve leaflets were not clearly seen. In the other cases, EU assisted the surgeon. Angioscopy and angiography were available for comparison. In one case, angioscopy failed because of inability to clear the field while inspecting retrograde the limb of an aorto-bi-femoral graft. EU however was possible. No complications of EU occurred. EU is a safe procedure indicated when characterization of a lesion is needed prior to an intervention or when evaluation of the intervention's success is desired. We did not find it useful in valve lysis for in-site grafting.

  11. Target volume definition for post prostatectomy radiotherapy: Do the consensus guidelines correctly define the inferior border of the CTV?

    PubMed

    Manji, Mo; Crook, Juanita; Schmid, Matt; Rajapakshe, Rasika

    2016-01-01

    We compare urethrogram delineation of the caudal aspect of the anastomosis to the recommended guidelines of post prostatectomy radiotherapy. Level one evidence has established the indications for, and importance of, adjuvant radiotherapy following radical prostatectomy. Several guidelines have recently addressed delineation of the prostate bed target volume including identification of the vesico-urethral anastomosis, taken as the first CT slice caudal to visible urine in the bladder neck. The inferior border of clinical target volume is then variably defined 5-12 mm below this anastomosis or 15 mm cranial to the penile bulb. Thirty-three patients who received adjuvant radiotherapy following radical prostatectomy were reviewed. All underwent planning CT with urethrogram. The authors (MM, JC) independently identified the CT slice caudal to the last slice showing urine in the bladder neck (called the CT Reference Slice), and measured the distance between this and the tip of the urethrogram cone. Five patients also had a diagnostic MRI at the time of CT planning to better visualize the anatomy. Sixty-six readings were obtained. The mean distance between the Bladder CT Reference Slice and the most cranial urethrogram contrast slice was 16.1 mm (MM 16.4 mm, JC 15.8 mm), range: 6.8-34.2 mm. The mean distance between the urethrogram tip and the ischial tuberosities was 19.9 mm (range 12.5-29.8 mm). The mean distance between the CT Reference Slice and the ischial tuberosities was 36.9 mm (range 28.3-52.4 mm). Guidelines for prostate bed radiation post prostatectomy have been developed after publication of the trials proving benefit of such treatment, and are thus untested. The anastomosis is a frequent site of local relapse but is variably defined by the existing guidelines, none of which take into account anatomic patient variation and all of which are at variance with urethrogram data. We recommend the use of planning urethrogram to better delineate the vesico

  12. Rapid Intraoperative Molecular Characterization of Glioma

    PubMed Central

    Shankar, Ganesh M.; Francis, Joshua M.; Rinne, Mikael L.; Ramkissoon, Shakti H.; Huang, Franklin W.; Venteicher, Andrew S.; Akama-Garren, Elliot H.; Kang, Yun Jee; Lelic, Nina; Kim, James C.; Brown, Loreal E.; Charbonneau, Sarah K.; Golby, Alexandra J.; Pedamallu, Chandra Sekhar; Hoang, Mai P.; Sullivan, Ryan J.; Cherniack, Andrew D.; Garraway, Levi A.; Stemmer-Rachamimov, Anat; Reardon, David A.; Wen, Patrick Y.; Brastianos, Priscilla K.; Curry, William T.; Barker, Fred G.; Hahn, William C.; Nahed, Brian V.; Ligon, Keith L.; Louis, David N.; Cahill, Daniel P.; Meyerson, Matthew

    2016-01-01

    IMPORTANCE Conclusive intraoperative pathologic confirmation of diffuse infiltrative glioma guides the decision to pursue definitive neurosurgical resection. Establishing the intraoperative diagnosis by histologic analysis can be difficult in low-cellularity infiltrative gliomas. Therefore, we developed a rapid and sensitive genotyping assay to detect somatic single-nucleotide variants in the telomerase reverse transcriptase (TERT) promoter and isocitrate dehydrogenase 1 (IDH1). OBSERVATIONS This assay was applied to tissue samples from 190 patients with diffuse gliomas, including archived fixed and frozen specimens and tissue obtained intraoperatively. Results demonstrated 96% sensitivity (95% CI, 90%–99%) and 100% specificity (95% CI, 95%–100%) for World Health Organization grades II and III gliomas. In a series of live cases, glioma-defining mutations could be identified within 60 minutes, which could facilitate the diagnosis in an intraoperative timeframe. CONCLUSIONS AND RELEVANCE The genotyping method described herein can establish the diagnosis of low-cellularity tumors like glioma and could be adapted to the point-of-care diagnosis of other lesions that are similarly defined by highly recurrent somatic mutations. PMID:26181761

  13. Computation of mean and variance of the radiotherapy dose for PCA-modeled random shape and position variations of the target.

    PubMed

    Budiarto, E; Keijzer, M; Storchi, P R M; Heemink, A W; Breedveld, S; Heijmen, B J M

    2014-01-20

    Radiotherapy dose delivery in the tumor and surrounding healthy tissues is affected by movements and deformations of the corresponding organs between fractions. The random variations may be characterized by non-rigid, anisotropic principal component analysis (PCA) modes. In this article new dynamic dose deposition matrices, based on established PCA modes, are introduced as a tool to evaluate the mean and the variance of the dose at each target point resulting from any given set of fluence profiles. The method is tested for a simple cubic geometry and for a prostate case. The movements spread out the distributions of the mean dose and cause the variance of the dose to be highest near the edges of the beams. The non-rigidity and anisotropy of the movements are reflected in both quantities. The dynamic dose deposition matrices facilitate the inclusion of the mean and the variance of the dose in the existing fluence-profile optimizer for radiotherapy planning, to ensure robust plans with respect to the movements.

  14. Multi-center study on patient selection for and the oncologic safety of intraoperative radiotherapy (IORT) with the Xoft Axxent® eBx® System for the management of early stage breast cancer in Taiwan.

    PubMed

    Lai, Hung-Wen; Liu, Liang-Chih; Ouyang, Fu; Yao, Chung-Chin; Jan, Hsiang-Chun; Chang, Ya-Herng; Tu, Chi-Wen; Chen, Dar-Ren; Cheng, Tsui-Fen; Tzeng, Yen-Dun; Hsu, Huan-Ming; Yeh, Ming-Hsin; Wu, Yao-Chung; Yang, Po-Sheng; Lam, Hung-Bun; Hou, Ming-Feng; Chen, Fang-Ming

    2017-01-01

    In this multi-center study, we report the patient selection criteria for and preliminary oncologic outcomes associated with intraoperative radiotherapy (IORT) delivered by the Xoft Axxent® eBx® system for early-stage breast cancer in Taiwan. Patients with early breast cancer in Taiwan received breast conserving surgery and received IORT with Xoft Axxent® eBx® System during 2013-2015 was search from database of Taiwan IORT study cooperative group (T-IORTSCG). Patients' clinicopathologic characteristics and early post-operative results were collected and reported. During the study period, 26 hospitals in Taiwan performed a total of 261 Xoft IORT procedures for breast cancer. The mean age of them was 52.9 ± 9.8 years (37-72), and tumor size was 1.5 ± 0.8 cm (0.1-4.2 cm) for invasive cancer and 1.2 ± 0.8 cm (range, 0.2-3.0 cm) for ductal carcinoma in situ (DCIS) lesions. Lymph node metastasis was found in 6 (2.3%) patients. The patients received IORT in Taiwan differed markedly from those used in the ELIOT and TARGIT-A studies. Specifically, patients selected for IORT in Taiwan tended to be younger, their tumors tended to be larger and the prevalence of lymph node metastasis tended to be lower. Among these 261 patients, 8 (3.1%) patients required whole breast radiotherapy. During a mean follow up of 15.6 months, locoregional recurrence was observed in 2 (0.8%) patients. In real world experience, patients received IORT differed quite significantly with criteria formulated by trials. The preliminary results of IORT in Taiwan showed it is well acceptable by patients and clinicians.

  15. Intra-fraction motion of larynx radiotherapy

    NASA Astrophysics Data System (ADS)

    Durmus, Ismail Faruk; Tas, Bora

    2018-02-01

    In early stage laryngeal radiotherapy, movement is an important factor. Thyroid cartilage can move from swallowing, breathing, sound and reflexes. The effects of this motion on the target volume (PTV) during treatment were examined. In our study, the target volume movement during the treatment for this purpose was examined. Thus, setup margins are re-evaluated and patient-based PTV margins are determined. Intrafraction CBCT was scanned in 246 fractions for 14 patients. During the treatment, the amount of deviation which could be lateral, vertical and longitudinal axis was determined. ≤ ± 0.1cm deviation; 237 fractions in the lateral direction, 202 fractions in the longitudinal direction, 185 fractions in the vertical direction. The maximum deviation values were found in the longitudinal direction. Intrafraction guide in laryngeal radiotherapy; we are sure of the correctness of the treatment, the target volume is to adjust the margin and dose more precisely, we control the maximum deviation of the target volume for each fraction. Although the image quality of intrafraction-CBCT scans was lower than the image quality of planning CT, they showed sufficient contrast for this work.

  16. Evaluation of dose coverage to target volume and normal tissue sparing in the adjuvant radiotherapy of gastric cancers: 3D-CRT compared with dynamic IMRT.

    PubMed

    Murthy, Kk; Shukeili, Ka; Kumar, Ss; Davis, Ca; Chandran, Rr; Namrata, S

    2010-01-01

    To assess the potential advantage of intensity-modulated radiotherapy (IMRT) over 3D-conformal radiotherapy (3D-CRT) planning in postoperative adjuvant radiotherapy for patients with gastric carcinoma. In a retrospective study, for plan comparison, dose distribution was recalculated in 15 patients treated with 3D-CRT on the contoured structures of same CT images using an IMRT technique. 3D-conformal plans with three fields and four-fields were compared with seven-field dynamic IMRT plans. The different plans were compared by analyzing the dose coverage of planning target volume using TV(95), D(mean), uniformity index, conformity index and homogeneity index parameters. To assess critical organ sparing, D(mean), D(max), dose to one-third and two-third volumes of the OARs and percentage of volumes receiving more than their tolerance doses were compared. The average dose coverage values of PTV with 3F-CRT and 4F-CRT plans were comparable, where as IMRT plans achieved better target coverage(p<0.001) with higher conformity index value of 0.81±0.07 compared to both the 3D-CRT plans. The doses to the liver and bowel reduced significantly (p<0.001) with IMRT plans compared to other 3D-CRT plans. For all OARs the percentage of volumes receiving more than their tolerance doses were reduced with the IMRT plans. This study showed that a better target coverage and significant dose reduction to OARs could be achieved with the IMRT plans. The IMRT can be preferred with caution for organ motion. The authors are currently studying organ motion in the upper abdomen to use IMRT for patient treatment.

  17. Diagnosis and Management of Intraoperative Colorectal Anastomotic Leaks: A Global Retrospective Patient Chart Review Study.

    PubMed

    Schiff, A; Roy, S; Pignot, M; Ghosh, S K; Fegelman, E J

    2017-01-01

    This targeted chart review study reports the first ever detailed global account of clinical approaches adopted to detect and manage anastomotic leaks identified during surgery in routine clinical practice. 156 surgeons from eight countries retrospectively extracted data from surgical records of 458 patients who underwent colorectal surgery with an identified intraoperative leak at the circular anastomosis. Demographic details, procedures, and outcomes were analyzed descriptively, by country. Most surgeries were performed laparoscopically (57.6%), followed by open surgeries (35.8%). The burden of intraoperative leaks on the healthcare system is driven in large part by the additional interventions such as using a sealant, recreating the anastomosis, and diverting the anastomosis to a colostomy bag, undertaken to manage the leak. The mean duration of hospitalization was 19.9 days. Postoperative anastomotic leaks occurred in 62 patients (13.5%), most frequently 4 to 7 days after surgery. Overall, country-specific differences were observed in patient characteristics, surgical procedures, method of diagnosis of intraoperative leak, interventions, and length of hospital stay. The potential cost of time and material needed to repair intraoperative leaks during surgery is substantial and often hidden to the healthcare system, potentially leading to an underestimation of the impact of this complication.

  18. Target volume definition for 18F-FDG PET-positive lymph nodes in radiotherapy of patients with non-small cell lung cancer.

    PubMed

    Nestle, Ursula; Schaefer-Schuler, Andrea; Kremp, Stephanie; Groeschel, Andreas; Hellwig, Dirk; Rübe, Christian; Kirsch, Carl-Martin

    2007-04-01

    FDG PET is increasingly used in radiotherapy planning. Recently, we demonstrated substantial differences in target volumes when applying different methods of FDG-based contouring in primary lung tumours (Nestle et al., J Nucl Med 2005;46:1342-8). This paper focusses on FDG-positive mediastinal lymph nodes (LN(PET)). In our institution, 51 NSCLC patients who were candidates for radiotherapy prospectively underwent staging FDG PET followed by a thoracic PET scan in the treatment position and a planning CT. Eleven of them had 32 distinguishable non-confluent mediastinal or hilar nodal FDG accumulations (LN(PET)). For these, sets of gross tumour volumes (GTVs) were generated at both acquisition times by four different PET-based contouring methods (visual: GTV(vis); 40% SUVmax: GTV40; SUV=2.5: GTV2.5; target/background (T/B) algorithm: GTV(bg)). All differences concerning GTV sizes were within the range of the resolution of the PET system. The detectability and technical delineability of the GTVs were significantly better in the late scans (e.g. p = 0.02 for diagnostic application of SUVmax = 2.5; p = 0.0001 for technical delineability by GTV2.5; p = 0.003 by GTV40), favouring the GTV(bg) method owing to satisfactory overall applicability and independence of GTVs from acquisition time. Compared with CT, the majority of PET-based GTVs were larger, probably owing to resolution effects, with a possible influence of lesion movements. For nodal GTVs, different methods of contouring did not lead to clinically relevant differences in volumes. However, there were significant differences in technical delineability, especially after early acquisition. Overall, our data favour a late acquisition of FDG PET scans for radiotherapy planning, and the use of a T/B algorithm for GTV contouring.

  19. Acute Intraoperative Pulmonary Aspiration

    PubMed Central

    Nason, Katie S.

    2015-01-01

    Synopsis Acute intraoperative aspiration is a potentially fatal complication with significant associated morbidity. Patients undergoing thoracic surgery are at increased risk for anesthesia-related aspiration, largely due to the predisposing conditions associated with this complication. Awareness of the risk factors, predisposing conditions, maneuvers to decrease risk and immediate management options by both the thoracic surgeon and the anesthesia team is imperative to reducing risk and optimizing patient outcomes associated with acute intraoperative pulmonary aspiration. Based on the root-cause analyses that many of the aspiration events can be traced back to provider factors, having an experienced anesthesiologist present for high-risk cases is also critical. PMID:26210926

  20. 3D ultrasound-based patient positioning for radiotherapy

    NASA Astrophysics Data System (ADS)

    Wang, Michael H.; Rohling, Robert N.; Archip, Neculai; Clark, Brenda G.

    2006-03-01

    A new 3D ultrasound-based patient positioning system for target localisation during radiotherapy is described. Our system incorporates the use of tracked 3D ultrasound scans of the target anatomy acquired using a dedicated 3D ultrasound probe during both the simulation and treatment sessions, fully automatic 3D ultrasound-toultrasound registration, and OPTOTRAK IRLEDs for registering simulation CT to ultrasound data. The accuracy of the entire radiotherapy treatment process resulting from the use of our system, from simulation to the delivery of radiation, has been validated on a phantom. The overall positioning error is less than 5mm, which includes errors from estimation of the irradiated region location in the phantom.

  1. Neurovascular bundle–sparing radiotherapy for prostate cancer using MRI-CT registration: A dosimetric feasibility study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cassidy, R.J., E-mail: richardjcassidy@emory.edu; Yang, X.; Liu, T.

    Purpose: Sexual dysfunction after radiotherapy for prostate cancer remains an important late adverse toxicity. The neurovascular bundles (NVB) that lie posterolaterally to the prostate are typically spared during prostatectomy, but in traditional radiotherapy planning they are not contoured as an organ-at-risk with dose constraints. Our goal was to determine the dosimetric feasibility of “NVB-sparing” prostate radiotherapy while still delivering adequate dose to the prostate. Methods: Twenty-five consecutive patients with prostate cancer (with no extraprostatic disease on pelvic magnetic resonance imaging [MRI]) who that were treated with external beam radiotherapy, with the same primary planning target volume margins, to a dosemore » of 79.2 Gy were evaluated. Pelvic MRI and simulation computed tomography scans were registered using dedicated software to allow for bilateral NVB target delineation on T2-weighted MRI. A volumetric modulated arc therapy plan was generated using the NVB bilaterally with 2 mm margin as an organ to spare and compared to the patient’s previously delivered plan. Dose-volume histogram endpoints for NVB, rectum, bladder, and planning target volume 79.2 were compared between the 2 plans using a 2-tailed paired t-test. Results: The V70 for the NVB was significantly lower on the NVB-sparing plan (p <0.01), while rectum and bladder endpoints were similar. Target V100% was similar but V{sub 105%} was higher for the NVB-sparing plans (p <0.01). Conclusions: “NVB-sparing” radiotherapy is dosimetrically feasible using CT-MRI registration, and for volumetric modulated arc therapy technology — target coverage is acceptable without increased dose to other normal structures, but with higher target dose inhomogeneity. The clinical impact of “NVB-sparing” radiotherapy is currently under study at our institution.« less

  2. Successful deep brain stimulation surgery with intraoperative magnetic resonance imaging on a difficult neuroacanthocytosis case: case report.

    PubMed

    Lim, Thien Thien; Fernandez, Hubert H; Cooper, Scott; Wilson, Kathryn Mary K; Machado, Andre G

    2013-07-01

    Chorea acanthocytosis is a progressive hereditary neurodegenerative disorder characterized by hyperkinetic movements, seizures, and acanthocytosis in the absence of any lipid abnormality. Medical treatment is typically limited and disappointing. We report on a 32-year-old patient with chorea acanthocytosis with a failed attempt at awake deep brain stimulation (DBS) surgery due to intraoperative seizures and postoperative intracranial hematoma. He then underwent a second DBS operation, but under general anesthesia and with intraoperative magnetic resonance imaging guidance. Marked improvement in his dystonia, chorea, and overall quality of life was noted 2 and 8 months postoperatively. DBS surgery of the bilateral globus pallidus pars interna may be useful in controlling the hyperkinetic movements in neuroacanthocytosis. Because of the high propensity for seizures in this disorder, DBS performed under general anesthesia, with intraoperative magnetic resonance imaging guidance, may allow successful implantation while maintaining accurate target localization.

  3. Beyond the margins: real-time detection of cancer using targeted fluorophores

    PubMed Central

    Zhang, Ray R.; Schroeder, Alexandra B.; Grudzinski, Joseph J.; Rosenthal, Eben L.; Warram, Jason M.; Pinchuk, Anatoly N.; Eliceiri, Kevin W.; Kuo, John S.; Weichert, Jamey P.

    2017-01-01

    Over the past two decades, synergistic innovations in imaging technology have resulted in a revolution in which a range of biomedical applications are now benefiting from fluorescence imaging. Specifically, advances in fluorophore chemistry and imaging hardware, and the identification of targetable biomarkers have now positioned intraoperative fluorescence as a highly specific real-time detection modality for surgeons in oncology. In particular, the deeper tissue penetration and limited autofluorescence of near-infrared (NIR) fluorescence imaging improves the translational potential of this modality over visible-light fluorescence imaging. Rapid developments in fluorophores with improved characteristics, detection instrumentation, and targeting strategies led to the clinical testing in the early 2010s of the first targeted NIR fluorophores for intraoperative cancer detection. The foundations for the advances that underline this technology continue to be nurtured by the multidisciplinary collaboration of chemists, biologists, engineers, and clinicians. In this Review, we highlight the latest developments in NIR fluorophores, cancer-targeting strategies, and detection instrumentation for intraoperative cancer detection, and consider the unique challenges associated with their effective application in clinical settings. PMID:28094261

  4. Co-targeting androgen receptor and DNA for imaging and molecular radiotherapy of prostate cancer: in vitro studies.

    PubMed

    Han, Guang; Kortylewicz, Zbigniew P; Enke, Thomas; Baranowska-Kortylewicz, Janina

    2014-12-01

    The androgen receptor (AR) axis, the key growth and survival pathway in prostate cancer, remains a prime target for drug development. 5-Radioiodo-3'-O-(17β-succinyl-5α-androstan-3-one)-2'-deoxyuridin-5'-yl phosphate (RISAD-P) is the AR-seeking reagent developed for noninvasive assessment of AR and proliferative status, and for molecular radiotherapy of prostate cancer with Auger electron-emitting radionuclides. RISAD-P radiolabeled with 123I, 124I, and 125I were synthesized using a common stannylated precursor. The cellular uptake, subcellular distribution, and radiotoxicity of 123I-, 124I-, and (125) IRISAD-P were measured in LNCaP, DU145, and PC-3 cell lines expressing various levels of AR. The uptake of RISAD-P by prostate cancer cells is proportional to AR levels and independent of the radionuclide. The intracellular accumulation of radioactivity is directly proportional to the extracellular concentration of RISAD-P and the duration of exposure. Initially, RISAD-P is trapped in the cytoplasm. Within 24 hr, radioactivity is associated exclusively with DNA. The RISAD-P radiotoxicity is determined by the radionuclide; however, the cellular responses are directly proportional to the AR expression levels. LNCaP cells expressing high levels of AR are killed at the rate of up to 60% per day after a brief 1 hr RISAD-P treatment. For the first time, the AR expression in PC-3 and DU 145 cells, generally reported as AR-negative, was quantitated by the ultra sensitive RISAD-P-based method. RISAD-P is a theranostic drug, which targets AR. Its subcellular metabolite participates in DNA synthesis. RISAD-P is a promising candidate for imaging of the AR expression and tumor proliferation as well as molecular radiotherapy of prostate cancer. © 2014 Wiley Periodicals, Inc.

  5. Intraoperative transfusion practices in Europe

    PubMed Central

    Meier, J.; Filipescu, D.; Kozek-Langenecker, S.; Llau Pitarch, J.; Mallett, S.; Martus, P.; Matot, I.

    2016-01-01

    Background. Transfusion of allogeneic blood influences outcome after surgery. Despite widespread availability of transfusion guidelines, transfusion practices might vary among physicians, departments, hospitals and countries. Our aim was to determine the amount of packed red blood cells (pRBC) and blood products transfused intraoperatively, and to describe factors determining transfusion throughout Europe. Methods. We did a prospective observational cohort study enrolling 5803 patients in 126 European centres that received at least one pRBC unit intraoperatively, during a continuous three month period in 2013. Results. The overall intraoperative transfusion rate was 1.8%; 59% of transfusions were at least partially initiated as a result of a physiological transfusion trigger- mostly because of hypotension (55.4%) and/or tachycardia (30.7%). Haemoglobin (Hb)- based transfusion trigger alone initiated only 8.5% of transfusions. The Hb concentration [mean (sd)] just before transfusion was 8.1 (1.7) g dl−1 and increased to 9.8 (1.8) g dl−1 after transfusion. The mean number of intraoperatively transfused pRBC units was 2.5 (2.7) units (median 2). Conclusion. Although European Society of Anaesthesiology transfusion guidelines are moderately implemented in Europe with respect to Hb threshold for transfusion (7–9 g dl−1), there is still an urgent need for further educational efforts that focus on the number of pRBC units to be transfused at this threshold. Clinical trial registration. NCT 01604083. PMID:26787795

  6. Intraoperative transfusion practices in Europe.

    PubMed

    Meier, J; Filipescu, D; Kozek-Langenecker, S; Llau Pitarch, J; Mallett, S; Martus, P; Matot, I

    2016-02-01

    Transfusion of allogeneic blood influences outcome after surgery. Despite widespread availability of transfusion guidelines, transfusion practices might vary among physicians, departments, hospitals and countries. Our aim was to determine the amount of packed red blood cells (pRBC) and blood products transfused intraoperatively, and to describe factors determining transfusion throughout Europe. We did a prospective observational cohort study enrolling 5803 patients in 126 European centres that received at least one pRBC unit intraoperatively, during a continuous three month period in 2013. The overall intraoperative transfusion rate was 1.8%; 59% of transfusions were at least partially initiated as a result of a physiological transfusion trigger- mostly because of hypotension (55.4%) and/or tachycardia (30.7%). Haemoglobin (Hb)- based transfusion trigger alone initiated only 8.5% of transfusions. The Hb concentration [mean (sd)] just before transfusion was 8.1 (1.7) g dl(-1) and increased to 9.8 (1.8) g dl(-1) after transfusion. The mean number of intraoperatively transfused pRBC units was 2.5 (2.7) units (median 2). Although European Society of Anaesthesiology transfusion guidelines are moderately implemented in Europe with respect to Hb threshold for transfusion (7-9 g dl(-1)), there is still an urgent need for further educational efforts that focus on the number of pRBC units to be transfused at this threshold. NCT 01604083. © The Author 2016. Published by Oxford University Press on behalf of the British Journal of Anaesthesia.

  7. The potential advantages of (18)FDG PET/CT-based target volume delineation in radiotherapy planning of head and neck cancer.

    PubMed

    Moule, Russell N; Kayani, Irfan; Moinuddin, Syed A; Meer, Khalda; Lemon, Catherine; Goodchild, Kathleen; Saunders, Michele I

    2010-11-01

    This study investigated two fixed threshold methods to delineate the target volume using (18)FDG PET/CT before and during a course of radical radiotherapy in locally advanced squamous cell carcinoma of the head and neck. Patients were enrolled into the study between March 2006 and May 2008. (18)FDG PET/CT scans were carried out 72h prior to the start of radiotherapy and then at 10, 44 and 66Gy. Functional volumes were delineated according to the SUV Cut Off (SUVCO) (2.5, 3.0, 3.5, and 4.0bwg/ml) and percentage of the SUVmax (30%, 35%, 40%, 45%, and 50%) thresholds. The background (18)FDG uptake and the SUVmax within the volumes were also assessed. Primary and lymph node volumes for the eight patients significantly reduced with each increase in the delineation threshold (for example 2.5-3.0bwg/ml SUVCO) compared to the baseline threshold at each imaging point. There was a significant reduction in the volume (p⩽0.0001-0.01) after 36Gy compared to the 0Gy by the SUVCO method. There was a negative correlation between the SUVmax within the primary and lymph node volumes and delivered radiation dose (p⩽0.0001-0.011) but no difference in the SUV within the background reference region. The volumes delineated by the PTSUVmax method increased with the increase in the delivered radiation dose after 36Gy because the SUVmax within the region of interest used to define the edge of the volume was equal or less than the background (18)FDG uptake and the software was unable to effectively differentiate between tumour and background uptake. The changes in the target volumes delineated by the SUVCO method were less susceptible to background (18)FDG uptake compared to those delineated by the PTSUVmax and may be more helpful in radiotherapy planning. The best method and threshold have still to be determined within institutions, both nationally and internationally. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  8. Small animal radiotherapy research platforms

    NASA Astrophysics Data System (ADS)

    Verhaegen, Frank; Granton, Patrick; Tryggestad, Erik

    2011-06-01

    Advances in conformal radiation therapy and advancements in pre-clinical radiotherapy research have recently stimulated the development of precise micro-irradiators for small animals such as mice and rats. These devices are often kilovolt x-ray radiation sources combined with high-resolution CT imaging equipment for image guidance, as the latter allows precise and accurate beam positioning. This is similar to modern human radiotherapy practice. These devices are considered a major step forward compared to the current standard of animal experimentation in cancer radiobiology research. The availability of this novel equipment enables a wide variety of pre-clinical experiments on the synergy of radiation with other therapies, complex radiation schemes, sub-target boost studies, hypofractionated radiotherapy, contrast-enhanced radiotherapy and studies of relative biological effectiveness, to name just a few examples. In this review we discuss the required irradiation and imaging capabilities of small animal radiation research platforms. We describe the need for improved small animal radiotherapy research and highlight pioneering efforts, some of which led recently to commercially available prototypes. From this, it will be clear that much further development is still needed, on both the irradiation side and imaging side. We discuss at length the need for improved treatment planning tools for small animal platforms, and the current lack of a standard therein. Finally, we mention some recent experimental work using the early animal radiation research platforms, and the potential they offer for advancing radiobiology research.

  9. Postoperative Intensity-Modulated Radiotherapy in Low-Risk Endometrial Cancers: Final Results of a Phase I Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Macchia, Gabriella, E-mail: gmacchia@rm.unicatt.i; Cilla, Savino M.P.; Ferrandina, Gabriella

    2010-04-15

    Purpose: To determine the maximum tolerated dose of short-course radiotherapy (intensity-modulated radiotherapy technique) to the upper two thirds of the vagina in endometrial cancers with low risk of local recurrence. Patients and Methods: A Phase I clinical trial was performed. Eligible patients had low-risk resected primary endometrial adenocarcinomas. Radiotherapy was delivered in 5 fractions over 1 week. The planning target volume was the clinical target volume plus 5 mm. The clinical target volume was defined as the upper two thirds of the vagina as evidenced at CT simulation by a vaginal radio-opaque device. The planning target volume was irradiated bymore » a seven-field intensity-modulated radiotherapy technique, planned by the Plato Sunrise inverse planning system. A first cohort of 6 patients received 25 Gy (5-Gy fractions), and a subsequent cohort received 30 Gy (6-Gy fractions). The Common Toxicity Criteria scale, version 3.0, was used to score toxicity. Results: Twelve patients with endometrial cancer were enrolled. Median age was 58 years (range, 49-74 years). Pathologic stage was IB (83.3%) and IC (16.7%). Median tumor size was 30 mm (range, 15-50 mm). All patients completed the prescribed radiotherapy. No patient experienced a dose-limiting toxicity at the first level, and the radiotherapy dose was escalated from 25 to 30 Gy. No patients at the second dose level experienced dose-limiting toxicity. The most common Grade 2 toxicity was gastrointestinal, which was tolerable and manageable. Conclusions: The maximum tolerated dose of short-course radiotherapy was 30 Gy at 6 Gy per fraction. On the basis of this result, we are conducting a Phase II study with radiotherapy delivered at 30 Gy.« less

  10. [Preoperative fluid management contributes to the prevention of intraoperative hypothermia].

    PubMed

    Yatabe, Tomoaki; Yokoyama, Masataka

    2011-07-01

    Intraoperative hypothermia causes several unfavorable events such as surgical site infection and cardiovascular events. Therefore, during anesthesia, temperature is routinely regulated, mainly by using external heating devices. Recently, oral amino acid intake and intravenous amino acid or fructose infusion have been reported to prevent intraoperative hypothermia during general and regional anesthesia. Diet (nutrient)-induced thermogenesis is considered to help prevent intraoperative hypothermia. Since the Enhanced Recovery After Surgery (ERAS) protocol has been introduced, it has been used in perioperative management in many hospitals. Prevention of intraoperative hypothermia is included in this protocol. According to the protocol, anesthesiologists play an important role in both intraoperative and perioperative management. Management of optimal body temperature by preoperative fluid management alone may be difficult. To this end, preoperative fluid management and nutrient management strategies such as preoperative oral fluid intake and carbohydrate loading have the potential to contribute to the prevention of intraoperative hypothermia.

  11. Edema and Seed Displacements Affect Intraoperative Permanent Prostate Brachytherapy Dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Westendorp, Hendrik, E-mail: r.westendorp@radiotherapiegroep.nl; Nuver, Tonnis T.; Department of Radiation Oncology, Radiotherapiegroep Behandellocatie Deventer, Deventer

    Purpose: We sought to identify the intraoperative displacement patterns of seeds and to evaluate the correlation of intraoperative dosimetry with day 30 for permanent prostate brachytherapy. Methods and Materials: We analyzed the data from 699 patients. Intraoperative dosimetry was acquired using transrectal ultrasonography (TRUS) and C-arm cone beam computed tomography (CBCT). Intraoperative dosimetry (minimal dose to 40%-95% of the volume [D{sub 40}-D{sub 95}]) was compared with the day 30 dosimetry for both modalities. An additional edema-compensating comparison was performed for D{sub 90}. Stranded seeds were linked between TRUS and CBCT using an automatic and fast linking procedure. Displacement patterns weremore » analyzed for each seed implantation location. Results: On average, an intraoperative (TRUS to CBCT) D{sub 90} decline of 10.6% ± 7.4% was observed. Intraoperative CBCT D{sub 90} showed a greater correlation (R{sup 2} = 0.33) with respect to Day 30 than did TRUS (R{sup 2} = 0.17). Compensating for edema, the correlation increased to 0.41 for CBCT and 0.38 for TRUS. The mean absolute intraoperative seed displacement was 3.9 ± 2.0 mm. The largest seed displacements were observed near the rectal wall. The central and posterior seeds showed less caudal displacement than lateral and anterior seeds. Seeds that were implanted closer to the base showed more divergence than seeds close to the apex. Conclusions: Intraoperative CBCT D{sub 90} showed a greater correlation with the day 30 dosimetry than intraoperative TRUS. Edema seemed to cause most of the systematic difference between the intraoperative and day 30 dosimetry. Seeds near the rectal wall showed the most displacement, comparing TRUS and CBCT, probably because of TRUS probe–induced prostate deformation.« less

  12. The value of intraoperative ultrasonography during the resection of relapsed irradiated malignant gliomas in the brain.

    PubMed

    Mursch, Kay; Scholz, Martin; Brück, Wolfgang; Behnke-Mursch, Julianne

    2017-01-01

    The aim of this study was to investigate whether intraoperative ultrasonography (IOUS) helped the surgeon navigate towards the tumor as seen in preoperative magnetic resonance imaging and whether IOUS was able to distinguish between tumor margins and the surrounding tissue. Twenty-five patients suffering from high-grade gliomas who were previously treated by surgery and radiotherapy were included. Intraoperatively, two histopathologic samples were obtained a sample of unequivocal tumor tissue (according to anatomical landmarks and the surgeon's visual and tactile impressions) and a small tissue sample obtained using a navigated needle when the surgeon decided to stop the resection. This specimen was considered to be a boundary specimen, where no tumor tissue was apparent. The decision to take the second sample was not influenced by IOUS. The effect of IOUS was analyzed semi-quantitatively. All 25 samples of unequivocal tumor tissue were histopathologically classified as tumor tissue and were hyperechoic on IOUS. Of the boundary specimens, eight were hypoechoic. Only one harbored tumor tissue (P=0.150). Seventeen boundaries were moderately hyperechoic, and these samples contained all possible histological results (i.e., tumor, infiltration, or no tumor). During surgery performed on relapsed, irradiated, high-grade gliomas, IOUS provided a reliable method of navigating towards the core of the tumor. At borders, it did not reliably distinguish between remnants or tumor-free tissue, but hypoechoic areas seldom contained tumor tissue.

  13. Selective serotonin reuptake inhibitors and intraoperative blood pressure.

    PubMed

    van Haelst, Ingrid M M; van Klei, Wilton A; Doodeman, Hieronymus J; Kalkman, Cor J; Egberts, Toine C G

    2012-02-01

    The influence of selective serotonin reuptake inhibitors (SSRIs) on blood pressure is poorly understood. We hypothesized that if SSRIs have an influence on blood pressure, this might become manifest in changes in intraoperative blood pressure. We aimed to study the association between perioperative use of SSRIs and changes in intraoperative blood pressure by measuring the occurrence of intraoperative hyper- and hypotension. We conducted a retrospective observational follow-up study among patients who underwent elective primary total hip arthroplasty. The index group included users of SSRIs. The reference group included a random sample (ratio 1:3) of nonusers of an antidepressant agent. The outcome was the occurrence of intraoperative hypo- and hypertensive episodes (number, mean and total duration, and area under the curve (AUC)). The outcome was adjusted for confounding factors using regression techniques. The index group included 20 users of an SSRI. The reference group included 60 nonusers. Users of SSRIs showed fewer intraoperative hypotensive episodes, a shorter mean and total duration, and a smaller AUC when compared to the reference group. After adjustment for confounders, SSRI use was associated with a significantly shorter total duration of hypotension: mean difference of -29.4 min (95% confidence interval (CI) -50.4 to -8.3). Two users of an SSRI and two patients in the reference group had a hypertensive episode. Continuation of treatment with SSRIs before surgery was associated with a briefer duration of intraoperative hypotension.

  14. [Intraoperative ultrasonography during laparoscopic surgery].

    PubMed

    Alecu, L; Lungu, C; Pascu, A; Costan, I; Corodeanu, G; Deacu, A; Marin, A

    2000-01-01

    Of this study is the introduction and the results evaluation of laparoscopic ultrasonography performed. We realize a prospective study about laparoscopic ultrasonography performed in 37 cases with laparoscopic surgical treatment. The Aloka SSD 2000 mobile scanner is used. This system make possible the use of an linear-array transducer, with mechanical flexibility and availability of Doppler analysis. Most frequently we used intraoperative ultrasonography in laparoscopic cholecystectomy as an alternative for cholangiography to exclude CBD pathology. Because of various surgical pathology with laparoscopic approach, the laparoscopic ultrasonography utilization range was vastly. In all the cases we could performed the laparoscopic ultrasonography. In 6 of 27 cases with laparoscopic cholecystectomy we found pathological disorders of bile ducts. CBD with diameter found between 5-12 mm. We properly saw the distal segment of CBD in 23 cases (89.2%), and common hepatic duct in 26 cases (97.3%). The quality of visualization was very good in 21 cases (83.8%) and moderate in 6 cases (16.2%). We easy identify CBD stones and we successfully used Doppler color mode in differentiating vascular from non-vascular from non-vascular structures. Laparoscopic ultrasonography performed in a case with left colon cancer excluded liver metastasis and lymph nodes metastasis. 1. Laparoscopic ultrasonography combines the advantages of diagnostic laparoscopy and intraoperative contact ultrasonography; 2. Laparoscopic ultrasonography is a simple and very efficient intraoperative examination procedure; 3. Laparoscopic ultrasonography is the technique to choose in CBD intraoperative exploration; 4. Laparoscopic ultrasonography improve abdominal malignancy exploration, thus modifying therapeutic decisions; 5. Color Doppler mode guides the surgeon's steps in difficult directions.

  15. Projected Improvements in Accelerated Partial Breast Irradiation Using a Novel Breast Stereotactic Radiotherapy Device: A Dosimetric Analysis.

    PubMed

    Snider, James W; Mutaf, Yildirim; Nichols, Elizabeth; Hall, Andrea; Vadnais, Patrick; Regine, William F; Feigenberg, Steven J

    2017-01-01

    Accelerated partial breast irradiation has caused higher than expected rates of poor cosmesis. At our institution, a novel breast stereotactic radiotherapy device has demonstrated dosimetric distributions similar to those in brachytherapy. This study analyzed comparative dose distributions achieved with the device and intensity-modulated radiation therapy accelerated partial breast irradiation. Nine patients underwent computed tomography simulation in the prone position using device-specific immobilization on an institutional review board-approved protocol. Accelerated partial breast irradiation target volumes (planning target volume_10mm) were created per the National Surgical Adjuvant Breast and Bowel Project B-39 protocol. Additional breast stereotactic radiotherapy volumes using smaller margins (planning target volume_3mm) were created based on improved immobilization. Intensity-modulated radiation therapy and breast stereotactic radiotherapy accelerated partial breast irradiation plans were separately generated for appropriate volumes. Plans were evaluated based on established dosimetric surrogates of poor cosmetic outcomes. Wilcoxon rank sum tests were utilized to contrast volumes of critical structures receiving a percentage of total dose ( Vx). The breast stereotactic radiotherapy device consistently reduced dose to all normal structures with equivalent target coverage. The ipsilateral breast V20-100 was significantly reduced ( P < .05) using planning target volume_10mm, with substantial further reductions when targeting planning target volume_3mm. Doses to the chest wall, ipsilateral lung, and breast skin were also significantly lessened. The breast stereotactic radiotherapy device's uniform dosimetric improvements over intensity-modulated accelerated partial breast irradiation in this series indicate a potential to improve outcomes. Clinical trials investigating this benefit have begun accrual.

  16. Validation of model-based brain shift correction in neurosurgery via intraoperative magnetic resonance imaging: preliminary results

    NASA Astrophysics Data System (ADS)

    Luo, Ma; Frisken, Sarah F.; Weis, Jared A.; Clements, Logan W.; Unadkat, Prashin; Thompson, Reid C.; Golby, Alexandra J.; Miga, Michael I.

    2017-03-01

    The quality of brain tumor resection surgery is dependent on the spatial agreement between preoperative image and intraoperative anatomy. However, brain shift compromises the aforementioned alignment. Currently, the clinical standard to monitor brain shift is intraoperative magnetic resonance (iMR). While iMR provides better understanding of brain shift, its cost and encumbrance is a consideration for medical centers. Hence, we are developing a model-based method that can be a complementary technology to address brain shift in standard resections, with resource-intensive cases as referrals for iMR facilities. Our strategy constructs a deformation `atlas' containing potential deformation solutions derived from a biomechanical model that account for variables such as cerebrospinal fluid drainage and mannitol effects. Volumetric deformation is estimated with an inverse approach that determines the optimal combinatory `atlas' solution fit to best match measured surface deformation. Accordingly, preoperative image is updated based on the computed deformation field. This study is the latest development to validate our methodology with iMR. Briefly, preoperative and intraoperative MR images of 2 patients were acquired. Homologous surface points were selected on preoperative and intraoperative scans as measurement of surface deformation and used to drive the inverse problem. To assess the model accuracy, subsurface shift of targets between preoperative and intraoperative states was measured and compared to model prediction. Considering subsurface shift above 3 mm, the proposed strategy provides an average shift correction of 59% across 2 cases. While further improvements in both the model and ability to validate with iMR are desired, the results reported are encouraging.

  17. A Bayesian nonrigid registration method to enhance intraoperative target definition in image-guided prostate procedures through uncertainty characterization

    PubMed Central

    Pursley, Jennifer; Risholm, Petter; Fedorov, Andriy; Tuncali, Kemal; Fennessy, Fiona M.; Wells, William M.; Tempany, Clare M.; Cormack, Robert A.

    2012-01-01

    Purpose: This study introduces a probabilistic nonrigid registration method for use in image-guided prostate brachytherapy. Intraoperative imaging for prostate procedures, usually transrectal ultrasound (TRUS), is typically inferior to diagnostic-quality imaging of the pelvis such as endorectal magnetic resonance imaging (MRI). MR images contain superior detail of the prostate boundaries and provide substructure features not otherwise visible. Previous efforts to register diagnostic prostate images with the intraoperative coordinate system have been deterministic and did not offer a measure of the registration uncertainty. The authors developed a Bayesian registration method to estimate the posterior distribution on deformations and provide a case-specific measure of the associated registration uncertainty. Methods: The authors adapted a biomechanical-based probabilistic nonrigid method to register diagnostic to intraoperative images by aligning a physician's segmentations of the prostate in the two images. The posterior distribution was characterized with a Markov Chain Monte Carlo method; the maximum a posteriori deformation and the associated uncertainty were estimated from the collection of deformation samples drawn from the posterior distribution. The authors validated the registration method using a dataset created from ten patients with MRI-guided prostate biopsies who had both diagnostic and intraprocedural 3 Tesla MRI scans. The accuracy and precision of the estimated posterior distribution on deformations were evaluated from two predictive distance distributions: between the deformed central zone-peripheral zone (CZ-PZ) interface and the physician-labeled interface, and based on physician-defined landmarks. Geometric margins on the registration of the prostate's peripheral zone were determined from the posterior predictive distance to the CZ-PZ interface separately for the base, mid-gland, and apical regions of the prostate. Results: The authors observed

  18. Development of effective prophylaxis against intraoperative carcinoid crisis.

    PubMed

    Woltering, Eugene A; Wright, Anne E; Stevens, Melissa A; Wang, Yi-Zarn; Boudreaux, John P; Mamikunian, Gregg; Riopelle, James M; Kaye, Alan D

    2016-08-01

    The prophylactic use of a preoperative, intraoperative, and postoperative high-dose continuous octreotide acetate infusion was evaluated for its ability to minimize the incidence of carcinoid crises during neuroendocrine tumor (NET) cytoreductive surgeries. A retrospective study was approved by the institutional review boards at Ochsner Medical Center-Kenner and Louisiana State University Health Sciences Center. Ochsner Medical Center-Kenner operating room and multispecialty NET clinic. One hundred fifty consecutive patients who underwent a total of 179 cytoreductive surgeries for stage IV, small bowel NETs. All patients received a 500-μg/h infusion of octreotide acetate preoperatively, intraoperatively, and postoperatively. Anesthesia and surgical records were reviewed. Carcinoid crisis was defined as a systolic blood pressure of less than 80mm Hg for greater than 10minutes. Patients who experienced intraoperative hypertension or hypotension, profound tachycardia, or a "crisis" according to the operative note were also reviewed. One hundred sixty-nine (169/179; 94%) patients had normal anesthesia courses. The medical records of 10 patients were further investigated for a potential intraoperative crisis using the aforementioned criteria. Upon review, 6 patients were determined to have had a crisis. The final incidence of intraoperative crisis was 3.4% (6/179). A continuous high-dose infusion of octreotide acetate intraoperatively minimizes the incidence of carcinoid crisis. We believe that the low cost and excellent safety profile of octreotide warrant the use of this therapy during extensive surgical procedures for midgut and foregut NETs. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Improving external beam radiotherapy by combination with internal irradiation.

    PubMed

    Dietrich, A; Koi, L; Zöphel, K; Sihver, W; Kotzerke, J; Baumann, M; Krause, M

    2015-07-01

    The efficacy of external beam radiotherapy (EBRT) is dose dependent, but the dose that can be applied to solid tumour lesions is limited by the sensitivity of the surrounding tissue. The combination of EBRT with systemically applied radioimmunotherapy (RIT) is a promising approach to increase efficacy of radiotherapy. Toxicities of both treatment modalities of this combination of internal and external radiotherapy (CIERT) are not additive, as different organs at risk are in target. However, advantages of both single treatments are combined, for example, precise high dose delivery to the bulk tumour via standard EBRT, which can be increased by addition of RIT, and potential targeting of micrometastases by RIT. Eventually, theragnostic radionuclide pairs can be used to predict uptake of the radiotherapeutic drug prior to and during therapy and find individual patients who may benefit from this treatment. This review aims to highlight the outcome of pre-clinical studies on CIERT and resultant questions for translation into the clinic. Few clinical data are available until now and reasons as well as challenges for clinical implementation are discussed.

  20. SU-F-J-34: Automatic Target-Based Patient Positioning Framework for Image-Guided Radiotherapy in Prostate Cancer Treatment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sasahara, M; Arimura, H; Hirose, T

    Purpose: Current image-guided radiotherapy (IGRT) procedure is bonebased patient positioning, followed by subjective manual correction using cone beam computed tomography (CBCT). This procedure might cause the misalignment of the patient positioning. Automatic target-based patient positioning systems achieve the better reproducibility of patient setup. Our aim of this study was to develop an automatic target-based patient positioning framework for IGRT with CBCT images in prostate cancer treatment. Methods: Seventy-three CBCT images of 10 patients and 24 planning CT images with digital imaging and communications in medicine for radiotherapy (DICOM-RT) structures were used for this study. Our proposed framework started from themore » generation of probabilistic atlases of bone and prostate from 24 planning CT images and prostate contours, which were made in the treatment planning. Next, the gray-scale histograms of CBCT values within CTV regions in the planning CT images were obtained as the occurrence probability of the CBCT values. Then, CBCT images were registered to the atlases using a rigid registration with mutual information. Finally, prostate regions were estimated by applying the Bayesian inference to CBCT images with the probabilistic atlases and CBCT value occurrence probability. The proposed framework was evaluated by calculating the Euclidean distance of errors between two centroids of prostate regions determined by our method and ground truths of manual delineations by a radiation oncologist and a medical physicist on CBCT images for 10 patients. Results: The average Euclidean distance between the centroids of extracted prostate regions determined by our proposed method and ground truths was 4.4 mm. The average errors for each direction were 1.8 mm in anteroposterior direction, 0.6 mm in lateral direction and 2.1 mm in craniocaudal direction. Conclusion: Our proposed framework based on probabilistic atlases and Bayesian inference might be feasible to

  1. Intraoperative monitoring of motor symptoms using surface electromyography during stereotactic surgery for movement disorders.

    PubMed

    Liu, Xuguang; Aziz, Tipu Z; Bain, Peter G

    2005-06-01

    The authors present practical evidence for the usefulness of intraoperative monitoring with surface electromyograms (sEMGs) from the affected muscles to assist electrode implantation and lesioning in patients with movement disorders. In 22 consecutive patients with various movement disorders, sEMGs were monitored in selected muscles during stereotactic surgery that involved either lesioning or electrode implantation. The electromyograms related to major motor symptoms such as tremor, rigidity, myoclonus, dystonia, and chorea were monitored and characterized on-line by both amplitude and frequency. Major motor symptoms were revealed by sEMGs recorded from the affected muscles. Tremor manifested as highly rhythmic bursts with a narrow frequency band; dyskinesias and chorea appeared as irregularly repeated bursts within a broad frequency range of 1 to 5 Hz; and rigidity and dystonia appeared as sustained high-frequency activity and co-contraction between antagonist muscles. The results suggest that intraoperative monitoring of sEMGs could help to functionally refine and confirm target localization. Surface EMGs could be used (1) as reference signals of the motor symptoms so that other signals, such as the oscillatory local field potentials simultaneously recorded via the implanted electrodes, could be correlated with the sEMGs and used to fine-tune or confirm the target localization; (2) to quantify the effects of acute electrical stimulation on the motor symptoms; and (3) to sensitively detect unwanted capsular responses induced by direct stimulation of the internal capsule. The authors conclude that intraoperative monitoring of sEMGs of the affected muscles of patients with movement disorders during stereotactic surgery provides sensitive and quantitative information that can contribute to improved electrode or lesion placement.

  2. Actual Time Required for Dynamic Fluoroscopic Intraoperative Cholangiography

    PubMed Central

    Whitwam, Paul; Turner, David; Kennedy, Kathy; Hashmi, Syed

    2005-01-01

    Objectives: This study was undertaken to determine the actual amount of time a dynamic fluoroscopic intraoperative cholangiogram adds to a laparoscopic cholecystectomy. A secondary objective was to define the information gained from this procedure. Methods: A consecutive case study of 52 patients undergoing laparoscopic cholecystectomy was used. Time was recorded from placement of a laparoscopic hemoclip across the cystic duct at its junction with the gallbladder until successful completion of the intraoperative cholangiogram. The mean, median, and range of times for these cases, as well as the results and false-negative rates, were determined. Results: Cholangiography was successfully completed in 96% of patients. The mean time added to laparoscopic cholecystectomy by the addition of dynamic fluoroscopic intraoperative cholangiography was 4.3 minutes. The median time was 3.0 minutes. The times ranged from 2.0 minutes to 16.0 minutes. Choledocholithiasis was present in 15.4% of these patients. The false-positive rate was zero in this study. Conclusions: Dynamic fluoroscopic intraoperative cholangiogram was fast and efficient. The information gained was significant in that 15% of patients proceeded on to laparoscopic common bile duct exploration. We conclude that intraoperative cholangiography should be a routine addition to laparoscopic cholecystectomy. PMID:15984705

  3. Intraoperative monitoring for intracranial aneurysms: the Michigan experience.

    PubMed

    Sahaya, Kinshuk; Pandey, Aditya S; Thompson, Byron G; Bush, Brian R; Minecan, Daniela N

    2014-12-01

    Intraoperative neurophysiological monitoring is routinely used during the repair (endovascular or microsurgical) of intracranial aneurysms at major centers. There is a continued need of data sets from institutions with dedicated intraoperative neurophysiological monitoring services to further define the predictive factors of postoperative neurological deficits. We retrospectively reviewed and analyzed our database of all patients who underwent repair of intracranial aneurysms (endovascular or microsurgical). A total of 406 patients underwent 470 procedures. The changes were noted during monitoring in 3.83% of the cases. Most of the changes were first detected in somatosensory evoked potential (88.89%) followed by brainstem auditory evoked potential (16.67%). Changes were completely reversible in 44.44%, only partly reversible in 22.22%, and irreversible in 33.33% of cases. Intraoperative neurophysiological monitoring changes demonstrated high sensitivity, specificity, and negative predictive value for postoperative neurological deficits. The association between intraoperative neurophysiological monitoring changes and Glasgow outcome scale was significant for reversible changes compared against irreversible and partly reversible changes. Presence of any intraoperative neurophysiological monitoring modality change during repair of intracranial aneurysm may suggest a higher risk for postoperative neurological deficits. Reversibility of the changes is a favorable marker, whereas irreversible changes are predictive of postoperative neurological deficits with deterioration of Glasgow outcome scale on a longer follow-up.

  4. Dosimetric comparison between conventional and conformal radiotherapy for carcinoma cervix: Are we treating the right volumes?

    PubMed Central

    Goswami, Jyotirup; Patra, Niladri B.; Sarkar, Biplab; Basu, Ayan; Pal, Santanu

    2013-01-01

    Background and Purpose: Conventional portals, based on bony anatomy, for external beam radiotherapy for cervical cancer have been repeatedly demonstrated as inadequate. Conversely, with image-based conformal radiotherapy, better target coverage may be offset by the greater toxicities and poorer compliance associated with treating larger volumes. This study was meant to dosimetrically compare conformal and conventional radiotherapy. Materials and Methods: Five patients of carcinoma cervix underwent planning CT scan with IV contrast and targets, and organs at risk (OAR) were contoured. Two sets of plans-conventional and conformal were generated for each patient. Field sizes were recorded, and dose volume histograms of both sets of plans were generated and compared on the basis of target coverage and OAR sparing. Results: Target coverage was significantly improved with conformal plans though field sizes required were significantly larger. On the other hand, dose homogeneity was not significantly improved. Doses to the OARs (rectum, urinary bladder, and small bowel) were not significantly different across the 2 arms. Conclusion: Three-dimensional conformal radiotherapy gives significantly better target coverage, which may translate into better local control and survival. On the other hand, it also requires significantly larger field sizes though doses to the OARs are not significantly increased. PMID:24455584

  5. Consensus Guidelines for Delineation of Clinical Target Volume for Intensity-Modulated Pelvic Radiotherapy in Postoperative Treatment of Endometrial and Cervical Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Small, William; Mell, Loren K.; Anderson, Penny

    2008-06-01

    Purpose: To develop an atlas of the clinical target volume (CTV) definitions for postoperative radiotherapy of endometrial and cervical cancer to be used for planning pelvic intensity-modulated radiotherapy. Methods and Materials: The Radiation Therapy Oncology Group led an international collaberation of cooperative groups in the development of the atlas. The groups included the Radiation Therapy Oncology Group, Gynecologic Oncology Group, National Cancer Institute of Canada, European Society of Therapeutic Radiology and Oncology, and American College of Radiology Imaging Network. The members of the group were asked by questionnaire to define the areas that were to be included in the CTVmore » and to outline theses areas on individual computed tomography images. The initial formulation of the group began in late 2004 and culminated with a formal consensus conference in June 2005. Results: The committee achieved a consensus CTV definition for postoperative therapy for endometrial and cervical cancer. The CTV should include the common, external, and internal iliac lymph node regions. The upper 3.0 cm of the vagina and paravaginal soft tissue lateral to the vagina should also be included. For patients with cervical cancer, or endometrial cancer with cervical stromal invasion, it is also recommended that the CTV include the presacral lymph node region. Conclusion: This report serves as an international template for the definition of the CTV for postoperative intensity-modulated radiotherapy for endometrial and cervical cancer.« less

  6. Intraoperative Frontal Alpha-Band Power Correlates with Preoperative Neurocognitive Function in Older Adults

    PubMed Central

    Giattino, Charles M.; Gardner, Jacob E.; Sbahi, Faris M.; Roberts, Kenneth C.; Cooter, Mary; Moretti, Eugene; Browndyke, Jeffrey N.; Mathew, Joseph P.; Woldorff, Marty G.; Berger, Miles; Berger, Miles

    2017-01-01

    Each year over 16 million older Americans undergo general anesthesia for surgery, and up to 40% develop postoperative delirium and/or cognitive dysfunction (POCD). Delirium and POCD are each associated with decreased quality of life, early retirement, increased 1-year mortality, and long-term cognitive decline. Multiple investigators have thus suggested that anesthesia and surgery place severe stress on the aging brain, and that patients with less ability to withstand this stress will be at increased risk for developing postoperative delirium and POCD. Delirium and POCD risk are increased in patients with lower preoperative cognitive function, yet preoperative cognitive function is not routinely assessed, and no intraoperative physiological predictors have been found that correlate with lower preoperative cognitive function. Since general anesthesia causes alpha-band (8–12 Hz) electroencephalogram (EEG) power to decrease occipitally and increase frontally (known as “anteriorization”), and anesthetic-induced frontal alpha power is reduced in older adults, we hypothesized that lower intraoperative frontal alpha power might correlate with lower preoperative cognitive function. Here, we provide evidence that such a correlation exists, suggesting that lower intraoperative frontal alpha power could be used as a physiological marker to identify older adults with lower preoperative cognitive function. Lower intraoperative frontal alpha power could thus be used to target these at-risk patients for possible therapeutic interventions to help prevent postoperative delirium and POCD, or for increased postoperative monitoring and follow-up. More generally, these results suggest that understanding interindividual differences in how the brain responds to anesthetic drugs can be used as a probe of neurocognitive function (and dysfunction), and might be a useful measure of neurocognitive function in older adults. PMID:28533746

  7. Intraoperative ultrasound of the pancreas.

    PubMed

    Shin, Lewis K; Brant-Zawadzki, Graham; Kamaya, Aya; Jeffrey, R Brooke

    2009-03-01

    Intraoperative ultrasound provides spatial resolution of the pancreas superior to computed tomography, magnetic resonance imaging, and transabdominal sonography. This pictorial essay will review common benign and malignant pancreatic processes including the following: pancreatic ductal adenocarcinoma, pancreatitis, endocrine tumors, mucinous cystic neoplasm, intraductal papillary mucinous neoplasm, serous cystadenoma, and solid pseudopapillary tumor. The use of intraoperative ultrasound in specific surgical situations will be discussed, which include the following: (1) identification of insulinoma(s) which are not detectable preoperatively, (2) identification of the pancreatic duct to determine dissection planes for chronic pancreatitis surgery (eg, Puestow procedure) and for tumor resection, and (3) staging purposes for malignant disease.

  8. MRI-Related Geometric Distortions in Stereotactic Radiotherapy Treatment Planning: Evaluation and Dosimetric Impact.

    PubMed

    Pappas, Eleftherios P; Alshanqity, Mukhtar; Moutsatsos, Argyris; Lababidi, Hani; Alsafi, Khalid; Georgiou, Konstantinos; Karaiskos, Pantelis; Georgiou, Evangelos

    2017-12-01

    In view of their superior soft tissue contrast compared to computed tomography, magnetic resonance images are commonly involved in stereotactic radiosurgery/radiotherapy applications for target delineation purposes. It is known, however, that magnetic resonance images are geometrically distorted, thus deteriorating dose delivery accuracy. The present work focuses on the assessment of geometric distortion inherent in magnetic resonance images used in stereotactic radiosurgery/radiotherapy treatment planning and attempts to quantitively evaluate the consequent impact on dose delivery. The geometric distortions for 3 clinical magnetic resonance protocols (at both 1.5 and 3.0 T) used for stereotactic radiosurgery/radiotherapy treatment planning were evaluated using a recently proposed phantom and methodology. Areas of increased distortion were identified at the edges of the imaged volume which was comparable to a brain scan. Although mean absolute distortion did not exceed 0.5 mm on any spatial axis, maximum detected control point disposition reached 2 mm. In an effort to establish what could be considered as acceptable geometric uncertainty, highly conformal plans were utilized to irradiate targets of different diameters (5-50 mm). The targets were mispositioned by 0.5 up to 3 mm, and dose-volume histograms and plan quality indices clinically used for plan evaluation and acceptance were derived and used to investigate the effect of geometrical uncertainty (distortion) on dose delivery accuracy and plan quality. The latter was found to be strongly dependent on target size. For targets less than 20 mm in diameter, a spatial disposition of the order of 1 mm could significantly affect (>5%) plan acceptance/quality indices. For targets with diameter greater than 2 cm, the corresponding disposition was found greater than 1.5 mm. Overall results of this work suggest that efficacy of stereotactic radiosurgery/radiotherapy applications could be compromised in case of very

  9. Voluntary Deep Inspiration Breath-hold Reduces the Heart Dose Without Compromising the Target Volume Coverage During Radiotherapy for Left-sided Breast Cancer.

    PubMed

    Al-Hammadi, Noora; Caparrotti, Palmira; Naim, Carole; Hayes, Jillian; Rebecca Benson, Katherine; Vasic, Ana; Al-Abdulla, Hissa; Hammoud, Rabih; Divakar, Saju; Petric, Primoz

    2018-03-01

    During radiotherapy of left-sided breast cancer, parts of the heart are irradiated, which may lead to late toxicity. We report on the experience of single institution with cardiac-sparing radiotherapy using voluntary deep inspiration breath hold (V-DIBH) and compare its dosimetric outcome with free breathing (FB) technique. Left-sided breast cancer patients, treated at our department with postoperative radiotherapy of breast/chest wall +/- regional lymph nodes between May 2015 and January 2017, were considered for inclusion. FB-computed tomography (CT) was obtained and dose-planning performed. Cases with cardiac V25Gy ≥ 5% or risk factors for heart disease were coached for V-DIBH. Compliant patients were included. They underwent additional CT in V-DIBH for planning, followed by V-DIBH radiotherapy. Dose volume histogram parameters for heart, lung and optimized planning target volume (OPTV) were compared between FB and BH. Treatment setup shifts and systematic and random errors for V-DIBH technique were compared with FB historic control. Sixty-three patients were considered for V-DIBH. Nine (14.3%) were non-compliant at coaching, leaving 54 cases for analysis. When compared with FB, V-DIBH resulted in a significant reduction of mean cardiac dose from 6.1 +/- 2.5 to 3.2 +/- 1.4 Gy (p < 0.001), maximum cardiac dose from 51.1 +/- 1.4 to 48.5 +/- 6.8 Gy (p = 0.005) and cardiac V25Gy from 8.5 +/- 4.2 to 3.2 +/- 2.5% (p < 0.001). Heart volumes receiving low (10-20 Gy) and high (30-50 Gy) doses were also significantly reduced. Mean dose to the left anterior coronary artery was 23.0 (+/- 6.7) Gy and 14.8 (+/- 7.6) Gy on FB and V-DIBH, respectively (p < 0.001). Differences between FB- and V-DIBH-derived mean lung dose (11.3 +/- 3.2 vs. 10.6 +/- 2.6 Gy), lung V20Gy (20.5 +/- 7 vs. 19.5 +/- 5.1 Gy) and V95% for the OPTV (95.6 +/- 4.1 vs. 95.2 +/- 6.3%) were non-significant. V-DIBH-derived mean shifts for initial patient setup were ≤ 2.7 mm. Random and systematic errors

  10. How to use PET/CT in the evaluation of response to radiotherapy.

    PubMed

    Decazes, Pierre; Thureau, Sébastien; Dubray, Bernard; Vera, Pierre

    2018-06-01

    Radiotherapy is a major treatment modality for many cancers. Tumor response after radiotherapy determines the subsequent steps of the patient's management (surveillance, adjuvant or salvage treatment and palliative care). Tumor response assessed during radiotherapy offers a promising opportunity to adapt the treatment plan to reduced or increased target volume, to specifically target sub-volumes with relevant biological characteristics (metabolism, hypoxia, proliferation, etc.) and to further spare the organs at risk. In addition to its role in the diagnosis and the initial staging, Positron Emission Tomography combined with a Computed Tomography (PET/CT) provides functional information and is therefore attractive to evaluate tumor response. The aim of this paper is to review the published data addressing PET/CT as an evaluation tool in irradiated tumors. Reports on PET/CT acquired at various times (during radiotherapy, after initial (chemo-) radiotherapy, after definitive radiotherapy and during posttreatment follow-up) in solid tumors (lung, head-and-neck, cervix, esophagus, prostate and rectum) were collected and reviewed. Various tracers and technical aspects are also discussed. 18F-FDG PET/CT has a well-established role in clinical routine after definitive chemo-radiotherapy for locally advanced head-and-neck cancers. 18F-choline PET/CT is indicated in prostate cancer patients with biochemical failure. 18F-FDG PET/CT is optional in many other circumstances and the clinical benefits of assessing tumor response with PET/CT remain a field of very active research. The combination of PET with Magnetic Resonance Imaging (PET/MRI) may prove to be valuable in irradiated rectal and cervix cancers. Tumor response can be evaluated by PET/CT with clinical consequences in multiple situations, notably in head and neck and prostate cancers, after radiotherapy. Further clinical evaluation for most cancers is still needed, possibly in association to MRI.

  11. SU-E-J-159: Analysis of Total Imaging Uncertainty in Respiratory-Gated Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Suzuki, J; Okuda, T; Sakaino, S

    Purpose: In respiratory-gated radiotherapy, the gating phase during treatment delivery needs to coincide with the corresponding phase determined during the treatment plan. However, because radiotherapy is performed based on the image obtained for the treatment plan, the time delay, motion artifact, volume effect, and resolution in the images are uncertain. Thus, imaging uncertainty is the most basic factor that affects the localization accuracy. Therefore, these uncertainties should be analyzed. This study aims to analyze the total imaging uncertainty in respiratory-gated radiotherapy. Methods: Two factors of imaging uncertainties related to respiratory-gated radiotherapy were analyzed. First, CT image was used to determinemore » the target volume and 4D treatment planning for the Varian Realtime Position Management (RPM) system. Second, an X-ray image was acquired for image-guided radiotherapy (IGRT) for the BrainLAB ExacTrac system. These factors were measured using a respiratory gating phantom. The conditions applied during phantom operation were as follows: respiratory wave form, sine curve; respiratory cycle, 4 s; phantom target motion amplitude, 10, 20, and 29 mm (which is maximum phantom longitudinal motion). The target and cylindrical marker implanted in the phantom coverage of the CT images was measured and compared with the theoretically calculated coverage from the phantom motion. The theoretical position of the cylindrical marker implanted in the phantom was compared with that acquired from the X-ray image. The total imaging uncertainty was analyzed from these two factors. Results: In the CT image, the uncertainty between the target and cylindrical marker’s actual coverage and the coverage of CT images was 1.19 mm and 2.50mm, respectively. In the Xray image, the uncertainty was 0.39 mm. The total imaging uncertainty from the two factors was 1.62mm. Conclusion: The total imaging uncertainty in respiratory-gated radiotherapy was clinically acceptable

  12. Dosimetric comparison of carbon ion and X-ray radiotherapy for Stage IIIA non-small cell lung cancer.

    PubMed

    Kubo, Nobuteru; Saitoh, Jun-Ichi; Shimada, Hirofumi; Shirai, Katsuyuki; Kawamura, Hidemasa; Ohno, Tatsuya; Nakano, Takashi

    2016-09-01

    The present study compared the dose-volume histograms of patients with Stage IIIA non-small cell lung cancer (NSCLC) treated with carbon ion radiotherapy with those of patients treated with X-ray radiotherapy. Patients with Stage IIIA NSCLC (n = 10 patients for each approach) were enrolled. Both radiotherapy plans were calculated with the same targets and organs at risk on the same CT. The treatment plan for the prophylactic lymph node and primary tumor (PTV1) delivered 40 Gy for X-ray radiotherapy and 40 Gy (relative biological effectiveness; RBE) for carbon ion radiotherapy. The total doses for the primary tumor and clinically positive lymph nodes (PTV2) were 60 Gy for X-ray radiotherapy and 60 Gy (RBE) for carbon ion radiotherapy. The homogeneity indexes for PTV1 and PTV2 were superior for carbon ion radiotherapy in comparison with X-ray radiotherapy (PTV1, 0.57 vs 0.65, P = 0.009; PTV2, 0.07 vs 0.16, P = 0.005). The normal lung mean dose, V5, V10 and V20 for carbon ion radiotherapy were 7.7 Gy (RBE), 21.4%, 19.7% and 17.0%, respectively, whereas the corresponding doses for X-ray radiotherapy were 11.9 Gy, 34.9%, 26.6% and 20.8%, respectively. Maximum spinal cord dose, esophageal maximum dose and V50, and bone V10, V30 and V50 were lower with carbon ion radiotherapy than with X-ray radiotherapy. The present study indicates that carbon ion radiotherapy provides a more homogeneous target dose and a lower dose to organs at risk than X-ray radiotherapy for Stage IIIA non-small cell lung cancer. © The Author 2016. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  13. Intraoperative magnetic resonance imaging to update interactive navigation in neurosurgery: method and preliminary experience.

    PubMed

    Wirtz, C R; Bonsanto, M M; Knauth, M; Tronnier, V M; Albert, F K; Staubert, A; Kunze, S

    1997-01-01

    We report on the first successful intraoperative update of interactive image guidance based on an intraoperatively acquired magnetic resonance imaging (MRI) date set. To date, intraoperative imaging methods such as ultrasound, computerized tomography (CT), or MRI have not been successfully used to update interactive navigation. We developed a method of imaging patients intraoperatively with the surgical field exposed in an MRI scanner (Magnetom Open; Siemens Corp., Erlangen, Germany). In 12 patients, intraoperatively acquired 3D data sets were used for successful recalibration of neuronavigation, accounting for any anatomical changes caused by surgical manipulations. The MKM Microscope (Zeiss Corp., Oberkochen, Germany) was used as navigational system. With implantable fiducial markers, an accuracy of 0.84 +/- 0.4 mm for intraoperative reregistration was achieved. Residual tumor detected on MRI was consequently resected using navigation with the intraoperative data. No adverse effects were observed from intraoperative imaging or the use of navigation with intraoperative images, demonstrating the feasibility of recalibrating navigation with intraoperative MRI.

  14. SU-F-T-243: Major Risks in Radiotherapy. A Review Based On Risk Analysis Literature

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    López-Tarjuelo, J; Guasp-Tortajada, M; Iglesias-Montenegro, N

    Purpose: We present a literature review of risk analyses in radiotherapy to highlight the most reported risks and facilitate the spread of this valuable information so that professionals can be aware of these major threats before performing their own studies. Methods: We considered studies with at least an estimation of the probability of occurrence of an adverse event (O) and its associated severity (S). They cover external beam radiotherapy, brachytherapy, intraoperative radiotherapy, and stereotactic techniques. We selected only the works containing a detailed ranked series of elements or failure modes and focused on the first fully reported quartile as much.more » Afterward, we sorted the risk elements according to a regular radiotherapy procedure so that the resulting groups were cited in several works and be ranked in this way. Results: 29 references published between 2007 and February 2016 were studied. Publication trend has been generally rising. The most employed analysis has been the Failure mode and effect analysis (FMEA). Among references, we selected 20 works listing 258 ranked risk elements. They were sorted into 31 groups appearing at least in two different works. 11 groups appeared in at least 5 references and 5 groups did it in 7 or more papers. These last sets of risks where choosing another set of images or plan for planning or treating, errors related with contours, errors in patient positioning for treatment, human mistakes when programming treatments, and planning errors. Conclusion: There is a sufficient amount and variety of references for identifying which failure modes or elements should be addressed in a radiotherapy department before attempting a specific analysis. FMEA prevailed, but other studies such as “risk matrix” or “occurrence × severity” analyses can also lead professionals’ efforts. Risk associated with human actions ranks very high; therefore, they should be automated or at least peer-reviewed.« less

  15. Fluorescent imaging of cancerous tissues for targeted surgery

    PubMed Central

    Bu, Lihong; Shen, Baozhong; Cheng, Zhen

    2014-01-01

    To maximize tumor excision and minimize collateral damage is the primary goal of cancer surgery. Emerging molecular imaging techniques have to “image-guided surgery” developing into “molecular imaging-guided surgery”, which is termed “targeted surgery” in this review. Consequently, the precision of surgery can be advanced from tissue-scale to molecule-scale, enabling “targeted surgery” to be a component of “targeted therapy”. Evidence from numerous experimental and clinical studies has demonstrated significant benefits of fluorescent imaging in targeted surgery with preoperative molecular diagnostic screening. Fluorescent imaging can help to improve intraoperative staging and enable more radical cytoreduction, detect obscure tumor lesions in special organs, highlight tumor margins, better map lymph node metastases, and identify important normal structures intraoperatively. Though limited tissue penetration of fluorescent imaging and tumor heterogeneity are two major hurdles for current targeted surgery, multimodality imaging and multiplex imaging may provide potential solutions to overcome these issues, respectively. Moreover, though many fluorescent imaging techniques and probes have been investigated, targeted surgery remains at a proof-of-principle stage. The impact of fluorescent imaging on cancer surgery will likely be realized through persistent interdisciplinary amalgamation of research in diverse fields. PMID:25064553

  16. Review of intraoperative optical coherence tomography: technology and applications [Invited

    PubMed Central

    Carrasco-Zevallos, Oscar M.; Viehland, Christian; Keller, Brenton; Draelos, Mark; Kuo, Anthony N.; Toth, Cynthia A.; Izatt, Joseph A.

    2017-01-01

    During microsurgery, en face imaging of the surgical field through the operating microscope limits the surgeon’s depth perception and visualization of instruments and sub-surface anatomy. Surgical procedures outside microsurgery, such as breast tumor resections, may also benefit from visualization of the sub-surface tissue structures. The widespread clinical adoption of optical coherence tomography (OCT) in ophthalmology and its growing prominence in other fields, such as cancer imaging, has motivated the development of intraoperative OCT for real-time tomographic visualization of surgical interventions. This article reviews key technological developments in intraoperative OCT and their applications in human surgery. We focus on handheld OCT probes, microscope-integrated OCT systems, and OCT-guided laser treatment platforms designed for intraoperative use. Moreover, we discuss intraoperative OCT adjuncts and processing techniques currently under development to optimize the surgical feedback derivable from OCT data. Lastly, we survey salient clinical studies of intraoperative OCT for human surgery. PMID:28663853

  17. Intraoperative cerebral blood flow imaging of rodents

    NASA Astrophysics Data System (ADS)

    Li, Hangdao; Li, Yao; Yuan, Lu; Wu, Caihong; Lu, Hongyang; Tong, Shanbao

    2014-09-01

    Intraoperative monitoring of cerebral blood flow (CBF) is of interest to neuroscience researchers, which offers the assessment of hemodynamic responses throughout the process of neurosurgery and provides an early biomarker for surgical guidance. However, intraoperative CBF imaging has been challenging due to animal's motion and position change during the surgery. In this paper, we presented a design of an operation bench integrated with laser speckle contrast imager which enables monitoring of the CBF intraoperatively. With a specially designed stereotaxic frame and imager, we were able to monitor the CBF changes in both hemispheres during the rodent surgery. The rotatable design of the operation plate and implementation of online image registration allow the technician to move the animal without disturbing the CBF imaging during surgery. The performance of the system was tested by middle cerebral artery occlusion model of rats.

  18. Mild intraoperative hypothermia reduces free tissue transfer thrombosis.

    PubMed

    Liu, Yuen-Jong; Hirsch, Brandon P; Shah, Asad A; Reid, Marjorie A; Thomson, J Grant

    2011-02-01

    Patients undergoing free tissue transfer are particularly susceptible to hypothermia. The goal was to investigate the impact of intraoperative core body temperature on free flap thrombosis. Two hundred twelve cases of free flap reconstruction at Yale-New Haven Hospital between 1992 and 2008 were reviewed. Free flap thrombosis was defined by complete flap necrosis or direct visualization of arterial or venous thrombosis. Temperature measurements were calibrated to bladder temperatures as measured by Foley catheter sensor. Through logistic regression analysis, maximum and minimum intraoperative temperatures were determined to be statistically significant predictors of free flap thrombosis. The optimal temperature was calculated to be 36.2 °C, and maximum intraoperative temperatures between 36.0 °C and 36.4 °C showed lower thrombosis rates than super-warmed patients ( P < 0.03). Therefore, free flap patients should be mildly hypothermic at 36.0 °C to 36.4 °C, compared with normothermia at 37.5 °C, as measured in the bladder. A prospective randomized trial investigating thrombosis rates and intraoperative temperature should be undertaken. © Thieme Medical Publishers.

  19. A Bayesian nonrigid registration method to enhance intraoperative target definition in image-guided prostate procedures through uncertainty characterization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pursley, Jennifer; Risholm, Petter; Fedorov, Andriy

    2012-11-15

    Purpose: This study introduces a probabilistic nonrigid registration method for use in image-guided prostate brachytherapy. Intraoperative imaging for prostate procedures, usually transrectal ultrasound (TRUS), is typically inferior to diagnostic-quality imaging of the pelvis such as endorectal magnetic resonance imaging (MRI). MR images contain superior detail of the prostate boundaries and provide substructure features not otherwise visible. Previous efforts to register diagnostic prostate images with the intraoperative coordinate system have been deterministic and did not offer a measure of the registration uncertainty. The authors developed a Bayesian registration method to estimate the posterior distribution on deformations and provide a case-specific measuremore » of the associated registration uncertainty. Methods: The authors adapted a biomechanical-based probabilistic nonrigid method to register diagnostic to intraoperative images by aligning a physician's segmentations of the prostate in the two images. The posterior distribution was characterized with a Markov Chain Monte Carlo method; the maximum a posteriori deformation and the associated uncertainty were estimated from the collection of deformation samples drawn from the posterior distribution. The authors validated the registration method using a dataset created from ten patients with MRI-guided prostate biopsies who had both diagnostic and intraprocedural 3 Tesla MRI scans. The accuracy and precision of the estimated posterior distribution on deformations were evaluated from two predictive distance distributions: between the deformed central zone-peripheral zone (CZ-PZ) interface and the physician-labeled interface, and based on physician-defined landmarks. Geometric margins on the registration of the prostate's peripheral zone were determined from the posterior predictive distance to the CZ-PZ interface separately for the base, mid-gland, and apical regions of the prostate. Results: The authors

  20. Deep Brain Stimulation for Essential Tremor: Aligning Thalamic and Posterior Subthalamic Targets in 1 Surgical Trajectory.

    PubMed

    Bot, Maarten; van Rootselaar, Fleur; Contarino, Maria Fiorella; Odekerken, Vincent; Dijk, Joke; de Bie, Rob; Schuurman, Richard; van den Munckhof, Pepijn

    2017-12-21

    Ventral intermediate nucleus (VIM) deep brain stimulation (DBS) and posterior subthalamic area (PSA) DBS suppress tremor in essential tremor (ET) patients, but it is not clear which target is optimal. Aligning both targets in 1 surgical trajectory would facilitate exploring stimulation of either target in a single patient. To evaluate aligning VIM and PSA in 1 surgical trajectory for DBS in ET. Technical aspects of trajectories, intraoperative stimulation findings, final electrode placement, target used for chronic stimulation, and adverse and beneficial effects were evaluated. In 17 patients representing 33 trajectories, we successfully aligned VIM and PSA targets in 26 trajectories. Trajectory distance between targets averaged 7.2 (range 6-10) mm. In all but 4 aligned trajectories, optimal intraoperative tremor suppression was obtained in the PSA. During follow-up, active electrode contacts were located in PSA in the majority of cases. Overall, successful tremor control was achieved in 69% of patients. Stimulation-induced dysarthria or gait ataxia occurred in, respectively, 56% and 44% of patients. Neither difference in tremor suppression or side effects was noted between aligned and nonaligned leads nor between the different locations of chronic stimulation. Alignment of VIM and PSA for DBS in ET is feasible and enables intraoperative exploration of both targets in 1 trajectory. This facilitates positioning of electrode contacts in both areas, where multiple effective points of stimulation can be found. In the majority of aligned leads, optimal intraoperative and chronic stimulation were located in the PSA. Copyright © 2017 by the Congress of Neurological Surgeons

  1. Accelerated partial breast irradiation using robotic radiotherapy: a dosimetric comparison with tomotherapy and three-dimensional conformal radiotherapy.

    PubMed

    Rault, Erwann; Lacornerie, Thomas; Dang, Hong-Phuong; Crop, Frederik; Lartigau, Eric; Reynaert, Nick; Pasquier, David

    2016-02-27

    Accelerated partial breast irradiation (APBI) is a new breast treatment modality aiming to reduce treatment time using hypo fractionation. Compared to conventional whole breast irradiation that takes 5 to 6 weeks, APBI is reported to induce worse cosmetic outcomes both when using three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT). These late normal tissue effects may be attributed to the dose volume effect because a large portion of the non-target breast tissue volume (NTBTV) receives a high dose. In the context of APBI, non-coplanar beams could spare the NTBTV more efficiently. This study evaluates the dosimetric benefit of using the Cyberknife (CK) for APBI in comparison to IMRT (Tomotherapy) and three dimensional conformal radiotherapy (3D-CRT). The possibility of using surgical clips, implanted during surgery, to track target movements is investigated first. A phantom of a female thorax was designed in-house using the measurements of 20 patients. Surgical clips of different sizes were inserted inside the breast. A treatment plan was delivered to the mobile and immobile phantom. The motion compensation accuracy was evaluated using three radiochromic films inserted inside the breast. Three dimensional conformal radiotherapy (3D-CRT), Tomotherapy (TOMO) and CK treatment plans were calculated for 10 consecutive patients who received APBI in Lille. To ensure a fair comparison of the three techniques, margins applied to the CTV were set to 10 mm. However, a second CK plan was prepared using 3 mm margins to evaluate the benefits of motion compensation. Only the larger clips (VITALITEC Medium-Large) could be tracked inside the larger breast (all gamma indices below 1 for 1 % of the maximum dose and 1 mm). All techniques meet the guidelines defined in the NSABP/RTOG and SHARE protocols. As the applied dose volume constraints are very strong, insignificant dosimetric differences exist between techniques regarding the PTV

  2. Postoperative effects of intraoperative hyperglycemia in liver transplant patients.

    PubMed

    Kömürcü, Özgür; Camkıran Fırat, Aynur; Kaplan, Şerife; Torgay, Adnan; Pirat, Arash; Haberal, Mehmet; Arslan, Gülnaz

    2015-04-01

    The aim of this study was to determine the effects of intraoperative hyperglycemia on postoperative outcomes in orthotopic liver transplant recipients. After ethics committee approval was obtained, we retrospectively analyzed the records of patients who underwent orthotopic liver transplant from January 2000 to December 2013. A total 389 orthotopic liver transplants were performed in our center, but patients aged < 15 years (179 patients) were not included in the analyses. Patients were divided into 2 groups based on their maximum intraoperative blood glucose level: group 1 (patients with intraoperative blood glucose level < 200 mg/dL) and group 2 (patients with intraoperative blood glucose level > 200 mg/dL). Postoperative complications between the 2 groups were compared. There were 58 patients (37.6%; group 1, blood glucose < 200 mg/dL) who had controlled blood glucose and 96 patients (62.3%; group 2, blood glucose > 200 mg/dL) who had uncontrolled blood glucose. The mean age and weight for groups 1 and 2 were similar. There were no differences between the 2 groups regarding the duration of anhepatic phase (P = .20), operation time (P = .41), frequency of immediate intraoperative extubation (P = .14), and postoperative duration of mechanical ventilation (P = .06). There were no significant differences in frequency of patients who had postoperative infectious complications, acute kidney injury, or need for hemodialysis. Mortality rates after liver transplant were similar between the 2 groups (P = .81). Intraoperative hyperglycemia during orthotopic liver transplant was not associated with an increased risk of postoperative infection, acute renal failure, or mortality.

  3. Hippocampal-Sparing Whole-Brain Radiotherapy: A 'How-To' Technique Using Helical Tomotherapy and Linear Accelerator-Based Intensity-Modulated Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gondi, Vinai; Tolakanahalli, Ranjini; Mehta, Minesh P.

    2010-11-15

    Purpose: Sparing the hippocampus during cranial irradiation poses important technical challenges with respect to contouring and treatment planning. Herein we report our preliminary experience with whole-brain radiotherapy using hippocampal sparing for patients with brain metastases. Methods and Materials: Five anonymous patients previously treated with whole-brain radiotherapy with hippocampal sparing were reviewed. The hippocampus was contoured, and hippocampal avoidance regions were created using a 5-mm volumetric expansion around the hippocampus. Helical tomotherapy and linear accelerator (LINAC)-based intensity-modulated radiotherapy (IMRT) treatment plans were generated for a prescription dose of 30 Gy in 10 fractions. Results: On average, the hippocampal avoidance volume wasmore » 3.3 cm{sup 3}, occupying 2.1% of the whole-brain planned target volume. Helical tomotherapy spared the hippocampus, with a median dose of 5.5 Gy and maximum dose of 12.8 Gy. LINAC-based IMRT spared the hippocampus, with a median dose of 7.8 Gy and maximum dose of 15.3 Gy. On a per-fraction basis, mean dose to the hippocampus (normalized to 2-Gy fractions) was reduced by 87% to 0.49 Gy{sub 2} using helical tomotherapy and by 81% to 0.73 Gy{sub 2} using LINAC-based IMRT. Target coverage and homogeneity was acceptable with both IMRT modalities, with differences largely attributed to more rapid dose fall-off with helical tomotherapy. Conclusion: Modern IMRT techniques allow for sparing of the hippocampus with acceptable target coverage and homogeneity. Based on compelling preclinical evidence, a Phase II cooperative group trial has been developed to test the postulated neurocognitive benefit.« less

  4. Intraoperative Ultrasound to Assess for Pancreatic Duct Injuries

    DTIC Science & Technology

    2015-04-01

    cholecystocholangiopancreatography is often nondiagnostic, gastroenterologists may not be available for endoscopic retrograde cholangiopancreatography (ERCP...10MHz.We use the SonoSite MicroMaxx SLT 10-5 MHz 52mm broadband linear array intraoperative US probe ( FUJIFILM SonoSite, Inc., Bothell, WA). The duct...Intraoperative US Availability Is gastroenterology available? Is the fluoroscopic and endoscopic equipment available? Is MRCP available? Is a

  5. Stereoscopic Integrated Imaging Goggles for Multimodal Intraoperative Image Guidance

    PubMed Central

    Mela, Christopher A.; Patterson, Carrie; Thompson, William K.; Papay, Francis; Liu, Yang

    2015-01-01

    We have developed novel stereoscopic wearable multimodal intraoperative imaging and display systems entitled Integrated Imaging Goggles for guiding surgeries. The prototype systems offer real time stereoscopic fluorescence imaging and color reflectance imaging capacity, along with in vivo handheld microscopy and ultrasound imaging. With the Integrated Imaging Goggle, both wide-field fluorescence imaging and in vivo microscopy are provided. The real time ultrasound images can also be presented in the goggle display. Furthermore, real time goggle-to-goggle stereoscopic video sharing is demonstrated, which can greatly facilitate telemedicine. In this paper, the prototype systems are described, characterized and tested in surgeries in biological tissues ex vivo. We have found that the system can detect fluorescent targets with as low as 60 nM indocyanine green and can resolve structures down to 0.25 mm with large FOV stereoscopic imaging. The system has successfully guided simulated cancer surgeries in chicken. The Integrated Imaging Goggle is novel in 4 aspects: it is (a) the first wearable stereoscopic wide-field intraoperative fluorescence imaging and display system, (b) the first wearable system offering both large FOV and microscopic imaging simultaneously, (c) the first wearable system that offers both ultrasound imaging and fluorescence imaging capacities, and (d) the first demonstration of goggle-to-goggle communication to share stereoscopic views for medical guidance. PMID:26529249

  6. Usefulness of intraoperative ultrasonography in liver resections due to colon cancer metastasis.

    PubMed

    Lucchese, Angélica Maria; Kalil, Antônio Nocchi; Schwengber, Alex; Suwa, Eiji; Rolim de Moura, Gabriel Garcia

    2015-08-01

    Intraoperative ultrasonography (IOUS) of the liver has been used both as an aid for intraoperative anatomical definition and for the detection of new lesions. The present study aimed to evaluate the impact of IOUS and to identify factors that can predict the detection of new lesions intraoperatively. In this observational and prospective study, with a cross-sectional design, patients with colorectal cancer metastases who underwent hepatectomy were selected. Abdominal computed tomography, magnetic resonance imaging, and positron emission tomography were the preoperative evaluation tests. All patients underwent IOUS performed by the same surgeon. The intraoperative findings were compared with the preoperative tests results. In total, 56 hepatectomies were evaluated. Half of the patients were men, with a mean age of 57 (30-85) years. New lesions were found intraoperatively in 12 patients (21.4% of cases) and were detected on both palpation and ultrasonography in 11 of these patients. Ultrasonography helped to revise the surgical plans by providing additional information in 35.7% of cases. On multivariate analysis, the presence of more than 4 preoperative nodules was predictive of the intraoperative occurrence of new lesions. IOUS remains the only way to evaluate the relationships between tumors, liver vascular structures, and bile ducts intraoperatively. Alone, IOUS was not useful for identifying new lesions intraoperatively, as all new lesions were also detected on palpation. The number of lesions diagnosed on preoperative tests influenced the probability of identifying new lesions intraoperatively. There may be additional influential factors. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  7. Integration of 3D intraoperative ultrasound for enhanced neuronavigation

    NASA Astrophysics Data System (ADS)

    Paulsen, Keith D.; Ji, Songbai; Hartov, Alex; Fan, Xiaoyao; Roberts, David W.

    2012-03-01

    True three-dimensional (3D) volumetric ultrasound (US) acquisitions stand to benefit intraoperative neuronavigation on multiple fronts. While traditional two-dimensional (2D) US and its tracked, hand-swept version have been recognized for many years to advantage significantly image-guided neurosurgery, especially when coregistered with preoperative MR scans, its unregulated and incomplete sampling of the surgical volume of interest have limited certain intraoperative uses of the information that are overcome through direct volume acquisition (i.e., through 2D scan-head transducer arrays). In this paper, we illustrate several of these advantages, including image-based intraoperative registration (and reregistration) and automated, volumetric displacement mapping for intraoperative image updating. These applications of 3D US are enabled by algorithmic advances in US image calibration, and volume rasterization and interpolation for multi-acquisition synthesis that will also be highlighted. We expect to demonstrate that coregistered 3D US is well worth incorporating into the standard neurosurgical navigational environment relative to traditional tracked, hand-swept 2D US.

  8. Intraoperative Secondary Insults During Orthopedic Surgery in Traumatic Brain Injury.

    PubMed

    Algarra, Nelson N; Lele, Abhijit V; Prathep, Sumidtra; Souter, Michael J; Vavilala, Monica S; Qiu, Qian; Sharma, Deepak

    2017-07-01

    Secondary insults worsen outcomes after traumatic brain injury (TBI). However, data on intraoperative secondary insults are sparse. The primary aim of this study was to examine the prevalence of intraoperative secondary insults during orthopedic surgery after moderate-severe TBI. We also examined the impact of intraoperative secondary insults on postoperative head computed tomographic scan, intracranial pressure (ICP), and escalation of care within 24 hours of surgery. We reviewed medical records of TBI patients 18 years and above with Glasgow Coma Scale score <13 who underwent single orthopedic surgery within 2 weeks of TBI. Secondary insults examined were: systemic hypotension (systolic blood pressure<90 mm Hg), intracranial hypertension (ICP>20 mm Hg), cerebral hypotension (cerebral perfusion pressure<50 mm Hg), hypercarbia (end-tidal CO2>40 mm Hg), hypocarbia (end-tidal CO2<30 mm Hg in absence of intracranial hypertension), hyperglycemia (glucose>200 mg/dL), hypoglycemia (glucose<60 mg/dL), and hyperthermia (temperature >38°C). A total of 78 patients (41 [18 to 81] y, 68% male) met the inclusion criteria. The most common intraoperative secondary insults were systemic hypotension (60%), intracranial hypertension and cerebral hypotension (50% and 45%, respectively, in patients with ICP monitoring), hypercarbia (32%), and hypocarbia (29%). Intraoperative secondary insults were associated with worsening of head computed tomography, postoperative decrease of Glasgow Coma Scale score by ≥2, and escalation of care. After Bonferroni correction, association between cerebral hypotension and postoperative escalation of care remained significant (P<0.001). Intraoperative secondary insults were common during orthopedic surgery in patients with TBI and were associated with postoperative escalation of care. Strategies to minimize intraoperative secondary insults are needed.

  9. A multicentre 'end to end' dosimetry audit of motion management (4DCT-defined motion envelope) in radiotherapy.

    PubMed

    Palmer, Antony L; Nash, David; Kearton, John R; Jafari, Shakardokht M; Muscat, Sarah

    2017-12-01

    External dosimetry audit is valuable for the assurance of radiotherapy quality. However, motion management has not been rigorously audited, despite its complexity and importance for accuracy. We describe the first end-to-end dosimetry audit for non-SABR (stereotactic ablative body radiotherapy) lung treatments, measuring dose accumulation in a moving target, and assessing adequacy of target dose coverage. A respiratory motion lung-phantom with custom-designed insert was used. Dose was measured with radiochromic film, employing triple-channel dosimetry and uncertainty reduction. The host's 4DCT scan, outlining and planning techniques were used. Measurements with the phantom static and then moving at treatment delivery separated inherent treatment uncertainties from motion effects. Calculated and measured dose distributions were compared by isodose overlay, gamma analysis, and we introduce the concept of 'dose plane histograms' for clinically relevant interpretation of film dosimetry. 12 radiotherapy centres and 19 plans were audited: conformal, IMRT (intensity modulated radiotherapy) and VMAT (volumetric modulated radiotherapy). Excellent agreement between planned and static-phantom results were seen (mean gamma pass 98.7% at 3% 2 mm). Dose blurring was evident in the moving-phantom measurements (mean gamma pass 88.2% at 3% 2 mm). Planning techniques for motion management were adequate to deliver the intended moving-target dose coverage. A novel, clinically-relevant, end-to-end dosimetry audit of motion management strategies in radiotherapy is reported. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Dose constraints for moderate hypofractionated radiotherapy for prostate cancer: The French genito-urinary group (GETUG) recommendations.

    PubMed

    Langrand-Escure, J; de Crevoisier, R; Llagostera, C; Créhange, G; Delaroche, G; Lafond, C; Bonin, C; Bideault, F; Sargos, P; Belhomme, S; Pasquier, D; Latorzeff, I; Supiot, S; Hennequin, C

    2018-04-01

    Considering recent phase III trials results, moderate hypofractionated radiotherapy can be considered as a standard treatment for low and intermediate risk prostate cancer management. This assessment call for a framework allowing homogeneous and reproducible practices in the different centers using this radiotherapy schedule. The French Genito-Urinary Group (GETUG) provides here recommendations for daily practice of moderate hypofractionated radiotherapy for prostate cancer, with indications, dose, fractionation, pre-treatment planning, volume of interest delineation (target volume and organs at risk) and margins, dose constraints and radiotherapy techniques. Copyright © 2018. Published by Elsevier SAS.

  11. Comparison of heart and coronary artery doses associated with intensity-modulated radiotherapy versus three-dimensional conformal radiotherapy for distal esophageal cancer.

    PubMed

    Kole, Thomas P; Aghayere, Osarhieme; Kwah, Jason; Yorke, Ellen D; Goodman, Karyn A

    2012-08-01

    To compare heart and coronary artery radiation exposure using intensity-modulated radiotherapy (IMRT) vs. four-field three-dimensional conformal radiotherapy (3D-CRT) treatment plans for patients with distal esophageal cancer undergoing chemoradiation. Nineteen patients with distal esophageal cancers treated with IMRT from March 2007 to May 2008 were identified. All patients were treated to 50.4 Gy with five-field IMRT plans. Theoretical 3D-CRT plans with four-field beam arrangements were generated. Dose-volume histograms of the planning target volume, heart, right coronary artery, left coronary artery, and other critical normal tissues were compared between the IMRT and 3D-CRT plans, and selected parameters were statistically evaluated using the Wilcoxon rank-sum test. Intensity-modulated radiotherapy treatment planning showed significant reduction (p < 0.05) in heart dose over 3D-CRT as assessed by average mean dose (22.9 vs. 28.2 Gy) and V30 (24.8% vs. 61.0%). There was also significant sparing of the right coronary artery (average mean dose, 23.8 Gy vs. 35.5 Gy), whereas the left coronary artery showed no significant improvement (mean dose, 11.2 Gy vs. 9.2 Gy), p = 0.11. There was no significant difference in percentage of total lung volume receiving at least 10, 15, or 20 Gy or in the mean lung dose between the planning methods. There were also no significant differences observed for the kidneys, liver, stomach, or spinal cord. Intensity-modulated radiotherapy achieved a significant improvement in target conformity as measured by the conformality index (ratio of total volume receiving 95% of prescription dose to planning target volume receiving 95% of prescription dose), with the mean conformality index reduced from 1.56 to 1.30 using IMRT. Treatment of patients with distal esophageal cancer using IMRT significantly decreases the exposure of the heart and right coronary artery when compared with 3D-CRT. Long-term studies are necessary to determine how this

  12. A method for deriving a 4D-interpolated balanced planning target for mobile tumor radiotherapy.

    PubMed

    Roland, Teboh; Hales, Russell; McNutt, Todd; Wong, John; Simari, Patricio; Tryggestad, Erik

    2012-01-01

    Tumor control and normal tissue toxicity are strongly correlated to the tumor and normal tissue volumes receiving high prescribed dose levels in the course of radiotherapy. Planning target definition is, therefore, crucial to ensure favorable clinical outcomes. This is especially important for stereotactic body radiation therapy of lung cancers, characterized by high fractional doses and steep dose gradients. The shift in recent years from population-based to patient-specific treatment margins, as facilitated by the emergence of 4D medical imaging capabilities, is a major improvement. The commonly used motion-encompassing, or internal-target volume (ITV), target definition approach provides a high likelihood of coverage for the mobile tumor but inevitably exposes healthy tissue to high prescribed dose levels. The goal of this work was to generate an interpolated balanced planning target that takes into account both tumor coverage and normal tissue sparing from high prescribed dose levels, thereby improving on the ITV approach. For each 4DCT dataset, 4D deformable image registration was used to derive two bounding targets, namely, a 4D-intersection and a 4D-composite target which minimized normal tissue exposure to high prescribed dose levels and maximized tumor coverage, respectively. Through definition of an "effective overlap volume histogram" the authors derived an "interpolated balanced planning target" intended to balance normal tissue sparing from prescribed doses with tumor coverage. To demonstrate the dosimetric efficacy of the interpolated balanced planning target, the authors performed 4D treatment planning based on deformable image registration of 4D-CT data for five previously treated lung cancer patients. Two 4D plans were generated per patient, one based on the interpolated balanced planning target and the other based on the conventional ITV target. Plans were compared for tumor coverage and the degree of normal tissue sparing resulting from the new

  13. Involved-node radiotherapy in early-stage Hodgkin's lymphoma. Definition and guidelines of the German Hodgkin Study Group (GHSG).

    PubMed

    Eich, Hans Theodor; Müller, Rolf-Peter; Engenhart-Cabillic, Rita; Lukas, Peter; Schmidberger, Heinz; Staar, Susanne; Willich, Normann

    2008-08-01

    Radiotherapy of Hodgkin's Lymphoma has evolved from extended-field to involved-field (IF) radiotherapy reducing toxicity whilst maintaining high cure rates. Recent publications recommend further reduction in the radiation field to involved-node (IN) radiotherapy; however, this concept has never been tested in a randomized trial. The German Hodgkin Study Group aims to compare it with standard IF radiotherapy in their future HD17 trial. ALL patients must be examined by the radiation oncologist before the start of chemotherapy. At that time, patients must have complete staging CT scans. For patients with IN radiotherapy, a radiation planning CT before and after chemotherapy with patients in the treatment position is recommended. Fusion techniques, allowing the overlapping of the pre- and postchemotherapy CT scans, should be used. Usage of PET-CT scans with patients in the treatment position is recommended, whenever possible. The clinical target volume encompasses the initial volume of the Lymph node(s) before chemotherapy and incorporates the initial Location and extent of the disease taking the displacement of the normal tissues into account. The margin of the planning target volume should be 2 cm in axial and 3 cm in craniocaudal direction. If necessary, it can be reduced to 1-1.5 cm. To minimize Lung and cardiac toxicity, the target definition in the mediastinum is different. The concept of IN radiotherapy has been proposed as a means to further improve the therapeutic ratio by reducing the risk of radiation-induced toxicity, including second malignancies. Field sizes wiLL further decrease compared to IF radiotherapy.

  14. Intraoperative intracavitary hyperthermic chemotherapy for malignant pleural mesothelioma

    PubMed Central

    2017-01-01

    Malignant pleural mesothelioma (MPM) is a dreadful disease with a poor prognosis. Multimodality therapy including surgical macroscopic complete resection is performed to treat operable MPM. Intraoperative intracavitary hyperthermic chemotherapy for MPM was reviewed. Appropriate papers published between 2006 and present were extracted by the PubMed advanced search by MPM (Title/Abstract), chemotherapy (Title/Abstract), and hyperthermia (All fields). Among the selected papers, those written in English, and treated more than ten MPM patients were reviewed. The intraoperative intracavitary hyperthermic chemotherapy has been performed following extrapleural pneumonectomy (EPP) or pleurectomy/decortication (P/D) for MPM. Cisplatin was mainly used for perfusion, and the morbidity and mortality was acceptable. In conclusion, the intraoperative intracavitary hyperthermic chemotherapy following EPP or P/D for MPM might enhance local control in the chest cavity. PMID:28706901

  15. Quality of radiotherapy reporting in randomized controlled trials of prostate cancer.

    PubMed

    Soon, Yu Yang; Chen, Desiree; Tan, Teng Hwee; Tey, Jeremy

    2018-06-07

    Good radiotherapy reporting in clinical trials of prostate radiotherapy is important because it will allow accurate reproducibility of radiotherapy treatment and minimize treatment variations that can affect patient outcomes. The aim of our study is to assess the quality of prostate radiotherapy (RT) treatment reporting in randomized controlled trials in prostate cancer. We searched MEDLINE for randomized trials of prostate cancer, published from 1996 to 2016 and included prostate RT as one of the intervention arms. We assessed if the investigators reported the ten criteria adequately in the trial reports: RT dose prescription method; RT dose-planning procedures; organs at risk (OAR) dose constraints; target volume definition, simulation procedures; treatment verification procedures; total RT dose; fractionation schedule; conduct of quality assurance (QA) as well as presence or absence of deviations in RT treatment planning and delivery. We performed multivariate logistic regression to determine the factors that may influence the quality of reporting. We found 59 eligible trials. There was significant variability in the quality of reporting. Target volume definition, total RT dose and fractionation schedule were reported adequately in 97% of included trials. OAR constraints, simulation procedures and presence or absence of deviations in RT treatment planning and delivery were reported adequately in 30% of included trials. Twenty-four trials (40%) reported seven criteria or more adequately. Multivariable logistic analysis showed that trials that published their quality assurance results and cooperative group trials were more likely to have adequate quality in reporting in at least seven criteria. There is significant variability in the quality of reporting on prostate radiotherapy treatment in randomized trials of prostate cancer. We need to have consensus guidelines to standardize the reporting of radiotherapy treatment in randomized trials.

  16. Intraoperatively Testing the Anastomotic Integrity of Esophagojejunostomy Using Methylene Blue.

    PubMed

    Celik, S; Almalı, N; Aras, A; Yılmaz, Ö; Kızıltan, R

    2017-03-01

    Intraoperative testing of gastrointestinal anastomosis effectively ensures anastomotic integrity. This study investigated whether the routine use of methylene blue intraoperatively identified leaks to reduce the postoperative proportion of clinical leaks. This study retrospectively analyzed consecutive total gastrectomies performed from January 2007 to December 2014 in a university hospital setting by a general surgical group that exclusively used the methylene blue test. All surgeries were performed for gastric or junctional cancers (n = 198). All reconstructions (Roux-en Y esophagojejunostomy) were performed using a stapler. The methylene blue test was used in 108 cases (group 1) via a nasojejunal tube. No test was performed for the other 90 cases (group 2). Intraoperative leakage rate, postoperative clinical leakage rate, length of hospitalization, and mortality rate were the outcome measures. The intraoperative leakage rate was 7.4% in group 1. The postoperative clinical leakage rate was 8.6%. The postoperative clinical leakage rate was 3.7% in group 1 and 14.4% in group 2 (p = 0.007). There were no postoperative clinical leaks when an intraoperative leak led to concomitant intraoperative repair. The median length of hospital stay was 6 days in group 1 and 8 days in group 2 (p < 0.001). One death occurred in each group. No test-related complications were observed. The methylene blue test for esophagojejunostomy is a safe and reliable method for the assessment of anastomosis integrity, especially in cases with difficult esophagojejunostomic construction.

  17. Radiosurgery and radiotherapy for sacral tumors.

    PubMed

    Gibbs, Iris C; Chang, Steven D

    2003-08-15

    Sacral tumors represent a small subset of spinal lesions and typically include chordomas, metastases, other primary bone tumors, and benign schwannomas. Resection is the standard treatment for many sacral tumors, but many types of sacral lesions have the potential for recurrence after excision. In these cases, adjuvant radiotherapy is often beneficial. Although conventional radiotherapy plays an important role in the management of spinal lesions, the radiation doses required for adequate local control of many sacral lesions generally exceed the tolerance doses of normal tissues, thus limiting its definitive role in the management of sacral tumors. Recent advances in the field of stereotactic radiosurgery have allowed precise targeting of the sacrum. In this report the authors review the use of these two forms of radiation treatment and their role in managing sacral tumors.

  18. Intraoperative neurophysiological responses in epileptic patients submitted to hippocampal and thalamic deep brain stimulation.

    PubMed

    Cukiert, Arthur; Cukiert, Cristine Mella; Argentoni-Baldochi, Meire; Baise, Carla; Forster, Cássio Roberto; Mello, Valeria Antakli; Burattini, José Augusto; Lima, Alessandra Moura

    2011-12-01

    appearance of RR was 3V. In 5 of the 6 patients submitted to Hip-DBS, an increase in inter-ictal spiking was noted unilaterally immediately after electrode insertion. Intraoperative LF stimulation did not modify temporal lobe spiking; on the other hand, HF was effective in abolishing inter-ictal spiking in 4 of the 6 patients studied. There was no immediate morbidity or mortality in this series. Macrostimulation might be used to confirm that the hardware was working properly. There was no typical RR derived from each studied thalamic nuclei after LF stimulation. On the other hand, absence of such RRs was highly suggestive of hardware malfunction or inadequate targeting. Thalamic-DBS (Th-DBS) RR was always bilateral after unilateral stimulation, although they somehow prevailed over the stimulated hemisphere. Contrary to Th-DBS, Hip-DBS gave rise to localized RR over the ipsolateral temporal neocortex, and absence of this response might very likely be related to inadequate targeting or hardware failure. Increased spiking was seen over temporal neocortex during hippocampal electrode insertion; this might point to the more epileptogenic hippocampal region in each individual patient. We did not notice any intraoperative response difference among patients with temporal lobe epilepsy with or without MTS. The relationship between these intraoperative findings and seizure outcome is not yet clear and should be further evaluated. 2011 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  19. Multiple reservoirs contribute to intraoperative bacterial transmission.

    PubMed

    Loftus, Randy W; Brown, Jeremiah R; Koff, Matthew D; Reddy, Sundara; Heard, Stephen O; Patel, Hetal M; Fernandez, Patrick G; Beach, Michael L; Corwin, Howard L; Jensen, Jens T; Kispert, David; Huysman, Bridget; Dodds, Thomas M; Ruoff, Kathryn L; Yeager, Mark P

    2012-06-01

    % environment, 23% patient, and 30% provider) stopcock transmission. The environment was a more likely source of stopcock contamination than provider hands (relative risk [RR] 1.91, confidence interval [CI] 1.09 to 3.35, P = 0.029) or patients (RR 2.56, CI 1.34 to 4.89, P = 0.002). Hospital site (odds ratio [OR] 5.09, CI 2.02 to 12.86, P = 0.001) and case 2 (OR 6.82, CI 4.03 to 11.5, P < 0.001) were significant predictors of stopcock contamination. Stopcock contamination was associated with increased mortality (OR 58.5, CI 2.32 to 1477, P = 0.014). Intraoperative bacterial contamination of patients and provider hands was linked to 30-day postoperative infections. Bacterial contamination of patients, provider hands, and the environment contributes to stopcock transmission events, but the surrounding patient environment is the most likely source. Stopcock contamination is associated with increased patient mortality. Patient and provider bacterial reservoirs contribute to 30-day postoperative infections. Multimodal programs designed to target each of these reservoirs in parallel should be studied intensely as a comprehensive approach to reducing intraoperative bacterial transmission.

  20. Intraoperative leak testing has no correlation with leak after laparoscopic sleeve gastrectomy.

    PubMed

    Sethi, Monica; Zagzag, Jonathan; Patel, Karan; Magrath, Melissa; Somoza, Eduardo; Parikh, Manish S; Saunders, John K; Ude-Welcome, Aku; Schwack, Bradley F; Kurian, Marina S; Fielding, George A; Ren-Fielding, Christine J

    2016-03-01

    Staple line leak is a serious complication of sleeve gastrectomy. Intraoperative methylene blue and air leak tests are routinely used to evaluate for leak; however, the utility of these tests is controversial. We hypothesize that the practice of routine intraoperative leak testing is unnecessary during sleeve gastrectomy. A retrospective cohort study was designed using a prospectively collected database of seven bariatric surgeons from two institutions. All patients who underwent sleeve gastrectomy from March 2012 to November 2014 were included. The performance of intraoperative leak testing and the type of test (air or methylene blue) were based on surgeon preference. Data obtained included BMI, demographics, comorbidity, presence of intraoperative leak test, result of test, and type of test. The primary outcome was leak rate between the leak test (LT) and no leak test (NLT) groups. SAS version 9.4 was used for univariate and multivariate analyses. A total of 1550 sleeve gastrectomies were included; most were laparoscopic (99.8%), except for one converted and two open cases. Routine intraoperative leak tests were performed in 1329 (85.7%) cases, while 221 (14.3%) did not have LTs. Of the 1329 cases with LTs, there were no positive intraoperative results. Fifteen (1%) patients developed leaks, with no difference in leak rate between the LT and NLT groups (1 vs. 1%, p = 0.999). After adjusting for baseline differences between the groups with a propensity analysis, the observed lack of association between leak and intraoperative leak test remained. In this cohort, leaks presented at a mean of 17.3 days postoperatively (range 1-67 days). Two patients with staple line leaks underwent repeat intraoperative leak testing at leak presentation, and the tests remained negative. Intraoperative leak testing has no correlation with leak due to laparoscopic sleeve gastrectomy and is not predictive of the later development of staple line leak.

  1. Effectiveness of timely intraoperative iodine irrigation during cataract surgery.

    PubMed

    Matsuura, Kazuki; Miyazaki, Dai; Sasaki, Shin-Ichi; Yakura, Keiko; Inoue, Yoshitsugu; Sakamoto, Masako

    2016-11-01

    To determine the antiseptic efficacy of timely intraoperative iodine irrigation during cataract surgery. A total of 198 eyes of 99 cataract surgery patients were studied. The eyes were randomly assigned to treatment with or without timely intraoperative iodine irrigation of the surgical field with an iodine compound equivalent to 0.33 % povidone-iodine. In eyes in the timely intraoperative iodine irrigation group, the ocular surface was irrigated twice intraoperatively-before the initial incision and before insertion of the intraocular lens (IOL). The efficacy of the antiseptic treatment was evaluated by culture tests using scrapings of the surface of the sclerocornea and conjunctiva to the left of the incision and by broad-range real-time PCR for bacterial 16S ribosomal DNA using scrapings from the right side of the incision. Following intraoperative application of the iodine, bacteria were not detected in cultures of the samples. For the control eyes without timely iodine irrigation, cultures of samples from five and two eyes were positive before the initial incision and before IOL insertion, respectively. The bacterial DNA copy number before the initial incision was 1.7 ± 0.5 × 10 3 , which was significantly lower than that of the control eyes (1.7 ± 0.6 × 10 4 ). For both groups of eyes, the bacterial DNA copy number was significantly lower before the IOL insertion depending on the time course. When the antiseptic effect of the iodine irrigation and time course on bacterial DNA copy number was analyzed using generalized mixed linear regression, both were found to be significantly effective. No significant intraoperative epithelial defect was observed. The postoperative corneal endothelial cell count did not differ significantly between the two groups of eyes. Timely iodine irrigation can serve as a simple and useful adjunctive disinfection step in cataract surgery.

  2. PSMA, EpCAM, VEGF and GRPR as imaging targets in locally recurrent prostate cancer after radiotherapy.

    PubMed

    Rybalov, Maxim; Ananias, Hildo J K; Hoving, Hilde D; van der Poel, Henk G; Rosati, Stefano; de Jong, Igle J

    2014-04-10

    In this retrospective pilot study, the expression of the prostate-specific membrane antigen (PSMA), the epithelial cell adhesion molecule (EpCAM), the vascular endothelial growth factor (VEGF) and the gastrin-releasing peptide receptor (GRPR) in locally recurrent prostate cancer after brachytherapy or external beam radiotherapy (EBRT) was investigated, and their adequacy for targeted imaging was analyzed. Prostate cancer specimens were collected of 17 patients who underwent salvage prostatectomy because of locally recurrent prostate cancer after brachytherapy or EBRT. Immunohistochemistry was performed. A pathologist scored the immunoreactivity in prostate cancer and stroma. Staining for PSMA was seen in 100% (17/17), EpCAM in 82.3% (14/17), VEGF in 82.3% (14/17) and GRPR in 100% (17/17) of prostate cancer specimens. Staining for PSMA, EpCAM and VEGF was seen in 0% (0/17) and for GRPR in 100% (17/17) of the specimens' stromal compartments. In 11.8% (2/17) of cases, the GRPR staining intensity of prostate cancer was higher than stroma, while in 88.2% (15/17), the staining was equal. Based on the absence of stromal staining, PSMA, EpCAM and VEGF show high tumor distinctiveness. Therefore, PSMA, EpCAM and VEGF can be used as targets for the bioimaging of recurrent prostate cancer after EBRT to exclude metastatic disease and/or to plan local salvage therapy.

  3. A new methodological approach for PET implementation in radiotherapy treatment planning.

    PubMed

    Bellan, Elena; Ferretti, Alice; Capirci, Carlo; Grassetto, Gaia; Gava, Marcello; Chondrogiannis, Sotirios; Virdis, Graziella; Marzola, Maria Cristina; Massaro, Arianna; Rubello, Domenico; Nibale, Otello

    2012-05-01

    In this paper, a new methodological approach to using PET information in radiotherapy treatment planning has been discussed. Computed tomography (CT) represents the primary modality to plan personalized radiation treatment, because it provides the basic electron density map for correct dose calculation. If PET scanning is also performed it is typically coregistered with the CT study. This operation can be executed automatically by a hybrid PET/CT scanner or, if the PET and CT imaging sets have been acquired through different equipment, by a dedicated module of the radiotherapy treatment planning system. Both approaches have some disadvantages: in the first case, the bore of a PET/CT system generally used in clinical practice often does not allow the use of certain bulky devices for patient immobilization in radiotherapy, whereas in the second case the result could be affected by limitations in window/level visualization of two different image modalities, and the displayed PET volumes can appear not to be related to the actual uptake into the patient. To overcome these problems, at our centre a specific procedure has been studied and tested in 30 patients, allowing good results of precision in the target contouring to be obtained. The process consists of segmentation of the biological target volume by a dedicated PET/CT console and its export to a dedicated radiotherapy system, where an image registration between the CT images acquired by the PET/CT scanner and a large-bore CT is performed. The planning target volume is contoured only on the large-bore CT and is used for virtual simulation, to individuate permanent skin markers on the patient.

  4. Dosimetric Evaluation of Intensity Modulated Radiotherapy and 4-Field 3-D Conformal Radiotherapy in Prostate Cancer Treatment

    PubMed Central

    Uysal, Bora; Beyzadeoğlu, Murat; Sager, Ömer; Dinçoğlan, Ferrat; Demiral, Selçuk; Gamsız, Hakan; Sürenkök, Serdar; Oysul, Kaan

    2013-01-01

    Objective: The purpose of this dosimetric study is the targeted dose homogeneity and critical organ dose comparison of 7-field Intensity Modulated Radiotherapy (IMRT) and 3-D 4-field conformal radiotherapy. Study Design: Cross sectional study. Material and Methods: Twenty patients with low and moderate risk prostate cancer treated at Gülhane Military Medical School Radiation Oncology Department between January 2009 and December 2009 are included in this study. Two seperate dosimetric plans both for 7-field IMRT and 3D-CRT have been generated for each patient to comparatively evaluate the dosimetric status of both techniques and all the patients received 7-field IMRT. Results: Dose-comparative evaluation of two techniques revealed the superiority of IMRT technique with statistically significantly lower femoral head doses along with reduced critical organ dose-volume parameters of bladder V60 (the volume receiving 60 Gy) and rectal V40 (the volume receiving 40 Gy) and V60. Conclusion: It can be concluded that IMRT is an effective definitive management tool for prostate cancer with improved critical organ sparing and excellent dose homogenization in target organs of prostate and seminal vesicles. PMID:25207069

  5. Intraoperative /sup 99m/Tc bone imaging in the treatment of benign osteoblastic tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sty, J.; Simons, G.

    1982-05-01

    Benign bone tumors can be successfully treated by local resection with the use of intraoperative bone imaging. Intraoperative bone imaging provided accurate localization of an osteoid osteoma in a patella of a 16-year-old girl when standard radiographs failed to demonstrate the lesion. In a case of osteoblastoma of the sacrum in a 12-year old girl, intraoperative scanning was used repeatedly to guide completeness of resection. In these cases in which routine intraoperative radiographs would have failed, intraoperative scanning proved to be essential for success.

  6. Single-arc volumetric-modulated arc therapy (sVMAT) as adjuvant treatment for gastric cancer: Dosimetric comparisons with three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Xin; Li, Guangjun; Zhang, Yingjie

    2013-01-01

    To compare the dosimetric differences between the single-arc volumetric-modulated arc therapy (sVMAT), 3-dimensional conformal radiotherapy (3D-CRT), and intensity-modulated radiotherapy (IMRT) techniques in treatment planning for gastric cancer as adjuvant radiotherapy. Twelve patients were retrospectively analyzed. In each patient's case, the parameters were compared based on the dose-volume histogram (DVH) of the sVMAT, 3D-CRT, and IMRT plans, respectively. Three techniques showed similar target dose coverage. The maximum and mean doses of the target were significantly higher in the sVMAT plans than that in 3D-CRT plans and in the 3D-CRT/IMRT plans, respectively, but these differences were clinically acceptable. The IMRT and sVMATmore » plans successfully achieved better target dose conformity, reduced the V{sub 20/30}, and mean dose of the left kidney, as well as the V{sub 20/30} of the liver, compared with the 3D-CRT plans. And the sVMAT technique reduced the V{sub 20} of the liver much significantly. Although the maximum dose of the spinal cord were much higher in the IMRT and sVMAT plans, respectively (mean 36.4 vs 39.5 and 40.6 Gy), these data were still under the constraints. Not much difference was found in the analysis of the parameters of the right kidney, intestine, and heart. The IMRT and sVMAT plans achieved similar dose distribution to the target, but superior to the 3D-CRT plans, in adjuvant radiotherapy for gastric cancer. The sVMAT technique improved the dose sparings of the left kidney and liver, compared with the 3D-CRT technique, but showed few dosimetric advantages over the IMRT technique. Studies are warranted to evaluate the clinical benefits of the VMAT treatment for patients with gastric cancer after surgery in the future.« less

  7. Utilization of PET-CT in target volume delineation for three-dimensional conformal radiotherapy in patients with non-small cell lung cancer and atelectasis.

    PubMed

    Yin, Li-Jie; Yu, Xiao-Bin; Ren, Yan-Gang; Gu, Guang-Hai; Ding, Tian-Gui; Lu, Zhi

    2013-03-18

    To investigate the utilization of PET-CT in target volume delineation for three-dimensional conformal radiotherapy in patients with non-small cell lung cancer (NSCLC) and atelectasis. Thirty NSCLC patients who underwent radical radiotherapy from August 2010 to March 2012 were included in this study. All patients were pathologically confirmed to have atelectasis by imaging examination. PET-CT scanning was performed in these patients. According to the PET-CT scan results, the gross tumor volume (GTV) and organs at risk (OARs, including the lungs, heart, esophagus and spinal cord) were delineated separately both on CT and PET-CT images. The clinical target volume (CTV) was defined as the GTV plus a margin of 6-8 mm, and the planning target volume (PTV) as the GTV plus a margin of 10-15mm. An experienced physician was responsible for designing treatment plans PlanCT and PlanPET-CT on CT image sets. 95% of the PTV was encompassed by the 90% isodose curve, and the two treatment plans kept the same beam direction, beam number, gantry angle, and position of the multi-leaf collimator as much as possible. The GTV was compared using a target delineation system, and doses distributions to OARs were compared on the basis of dose-volume histogram (DVH) parameters. The GTVCT and GTVPET-CT had varying degrees of change in all 30 patients, and the changes in the GTVCT and GTVPET-CT exceeded 25% in 12 (40%) patients. The GTVPET-CT decreased in varying degrees compared to the GTVCT in 22 patients. Their median GTVPET-CT and median GTVPET-CT were 111.4 cm3 (range, 37.8 cm3-188.7 cm3) and 155.1 cm3 (range, 76.2 cm3-301.0 cm3), respectively, and the former was 43.7 cm3 (28.2%) less than the latter. The GTVPET-CT increased in varying degrees compared to the GTVCT in 8 patients. Their median GTVPET-CT and median GTVPET-CT were 144.7 cm3 (range, 125.4 cm3-178.7 cm3) and 125.8 cm3 (range, 105.6 cm3-153.5 cm3), respectively, and the former was 18.9 cm3 (15.0%) greater than the latter

  8. Conformal Radiotherapy in the Treatment of Advanced Juvenile Nasopharyngeal Angiofibroma With Intracranial Extension: An Institutional Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chakraborty, Santam, E-mail: drsantam@gmail.com; Ghoshal, Sushmita; Patil, Vijay Maruti

    2011-08-01

    Purpose: To describe the results of conformal radiotherapy in advanced juvenile nasopharyngeal angiofibroma in a tertiary care institution. Methods and Materials: Retrospective chart review was conducted for 8 patients treated with conformal radiotherapy between 2006 and 2009. The median follow-up was 17 months. All patients had Stage IIIB disease with intracranial extension. Radiotherapy was considered as treatment because patients were deemed inoperable owing to extensive intracranial/intraorbital extension or proximity to optic nerve. All but 1 patient were treated with intensity-modulated radiotherapy using seven coplanar fields. Median (range) dose prescribed was 39.6 (30-46) Gy. Actuarial analysis of local control and descriptivemore » analysis of toxicity profile was conducted. Results: Despite the large and complex target volume (median planning target volume, 292 cm{sup 3}), intensity-modulated radiotherapy achieved conformal dose distributions (median van't Reit index, 0.66). Significant sparing of the surrounding organs at risk was obtained. No significant Grade 3/4 toxicities were experienced during or after treatment. Actual local control at 2 years was 87.5%. One patient died 1 month after radiotherapy secondary to massive epistaxis. The remaining 7 patients had progressive resolution of disease and were symptom-free at last follow-up. Persistent rhinitis was the only significant toxicity, seen in 1 patient. Conclusions: Conformal radiotherapy results in good local control with minimal acute and late side effects in juvenile nasopharyngeal angiofibromas, even in the presence of advanced disease.« less

  9. Reducing intraoperative red blood cell unit wastage in a large academic medical center.

    PubMed

    Whitney, Gina M; Woods, Marcella C; France, Daniel J; Austin, Thomas M; Deegan, Robert J; Paroskie, Allison; Booth, Garrett S; Young, Pampee P; Dmochowski, Roger R; Sandberg, Warren S; Pilla, Michael A

    2015-11-01

    The wastage of red blood cell (RBC) units within the operative setting results in significant direct costs to health care organizations. Previous education-based efforts to reduce wastage were unsuccessful at our institution. We hypothesized that a quality and process improvement approach would result in sustained reductions in intraoperative RBC wastage in a large academic medical center. Utilizing a failure mode and effects analysis supplemented with time and temperature data, key drivers of perioperative RBC wastage were identified and targeted for process improvement. Multiple contributing factors, including improper storage and transport and lack of accurate, locally relevant RBC wastage event data were identified as significant contributors to ongoing intraoperative RBC unit wastage. Testing and implementation of improvements to the process of transport and storage of RBC units occurred in liver transplant and adult cardiac surgical areas due to their history of disproportionately high RBC wastage rates. Process interventions targeting local drivers of RBC wastage resulted in a significant reduction in RBC wastage (p < 0.0001; adjusted odds ratio, 0.24; 95% confidence interval, 0.15-0.39), despite an increase in operative case volume over the period of the study. Studied process interventions were then introduced incrementally in the remainder of the perioperative areas. These results show that a multidisciplinary team focused on the process of blood product ordering, transport, and storage was able to significantly reduce operative RBC wastage and its associated costs using quality and process improvement methods. © 2015 AABB.

  10. Intraoperative virtual brain counseling

    NASA Astrophysics Data System (ADS)

    Jiang, Zhaowei; Grosky, William I.; Zamorano, Lucia J.; Muzik, Otto; Diaz, Fernando

    1997-06-01

    Our objective is to offer online real-tim e intelligent guidance to the neurosurgeon. Different from traditional image-guidance technologies that offer intra-operative visualization of medical images or atlas images, virtual brain counseling goes one step further. It can distinguish related brain structures and provide information about them intra-operatively. Virtual brain counseling is the foundation for surgical planing optimization and on-line surgical reference. It can provide a warning system that alerts the neurosurgeon if the chosen trajectory will pass through eloquent brain areas. In order to fulfill this objective, tracking techniques are involved for intra- operativity. Most importantly, a 3D virtual brian environment, different from traditional 3D digitized atlases, is an object-oriented model of the brain that stores information about different brain structures together with their elated information. An object-oriented hierarchical hyper-voxel space (HHVS) is introduced to integrate anatomical and functional structures. Spatial queries based on position of interest, line segment of interest, and volume of interest are introduced in this paper. The virtual brain environment is integrated with existing surgical pre-planning and intra-operative tracking systems to provide information for planning optimization and on-line surgical guidance. The neurosurgeon is alerted automatically if the planned treatment affects any critical structures. Architectures such as HHVS and algorithms, such as spatial querying, normalizing, and warping are presented in the paper. A prototype has shown that the virtual brain is intuitive in its hierarchical 3D appearance. It also showed that HHVS, as the key structure for virtual brain counseling, efficiently integrates multi-scale brain structures based on their spatial relationships.This is a promising development for optimization of treatment plans and online surgical intelligent guidance.

  11. Radiotherapy planning for glioblastoma based on a tumor growth model: improving target volume delineation.

    PubMed

    Unkelbach, Jan; Menze, Bjoern H; Konukoglu, Ender; Dittmann, Florian; Le, Matthieu; Ayache, Nicholas; Shih, Helen A

    2014-02-07

    Glioblastoma differ from many other tumors in the sense that they grow infiltratively into the brain tissue instead of forming a solid tumor mass with a defined boundary. Only the part of the tumor with high tumor cell density can be localized through imaging directly. In contrast, brain tissue infiltrated by tumor cells at low density appears normal on current imaging modalities. In current clinical practice, a uniform margin, typically two centimeters, is applied to account for microscopic spread of disease that is not directly assessable through imaging. The current treatment planning procedure can potentially be improved by accounting for the anisotropy of tumor growth, which arises from different factors: anatomical barriers such as the falx cerebri represent boundaries for migrating tumor cells. In addition, tumor cells primarily spread in white matter and infiltrate gray matter at lower rate. We investigate the use of a phenomenological tumor growth model for treatment planning. The model is based on the Fisher-Kolmogorov equation, which formalizes these growth characteristics and estimates the spatial distribution of tumor cells in normal appearing regions of the brain. The target volume for radiotherapy planning can be defined as an isoline of the simulated tumor cell density. This paper analyzes the model with respect to implications for target volume definition and identifies its most critical components. A retrospective study involving ten glioblastoma patients treated at our institution has been performed. To illustrate the main findings of the study, a detailed case study is presented for a glioblastoma located close to the falx. In this situation, the falx represents a boundary for migrating tumor cells, whereas the corpus callosum provides a route for the tumor to spread to the contralateral hemisphere. We further discuss the sensitivity of the model with respect to the input parameters. Correct segmentation of the brain appears to be the most

  12. Radiotherapy planning for glioblastoma based on a tumor growth model: improving target volume delineation

    NASA Astrophysics Data System (ADS)

    Unkelbach, Jan; Menze, Bjoern H.; Konukoglu, Ender; Dittmann, Florian; Le, Matthieu; Ayache, Nicholas; Shih, Helen A.

    2014-02-01

    Glioblastoma differ from many other tumors in the sense that they grow infiltratively into the brain tissue instead of forming a solid tumor mass with a defined boundary. Only the part of the tumor with high tumor cell density can be localized through imaging directly. In contrast, brain tissue infiltrated by tumor cells at low density appears normal on current imaging modalities. In current clinical practice, a uniform margin, typically two centimeters, is applied to account for microscopic spread of disease that is not directly assessable through imaging. The current treatment planning procedure can potentially be improved by accounting for the anisotropy of tumor growth, which arises from different factors: anatomical barriers such as the falx cerebri represent boundaries for migrating tumor cells. In addition, tumor cells primarily spread in white matter and infiltrate gray matter at lower rate. We investigate the use of a phenomenological tumor growth model for treatment planning. The model is based on the Fisher-Kolmogorov equation, which formalizes these growth characteristics and estimates the spatial distribution of tumor cells in normal appearing regions of the brain. The target volume for radiotherapy planning can be defined as an isoline of the simulated tumor cell density. This paper analyzes the model with respect to implications for target volume definition and identifies its most critical components. A retrospective study involving ten glioblastoma patients treated at our institution has been performed. To illustrate the main findings of the study, a detailed case study is presented for a glioblastoma located close to the falx. In this situation, the falx represents a boundary for migrating tumor cells, whereas the corpus callosum provides a route for the tumor to spread to the contralateral hemisphere. We further discuss the sensitivity of the model with respect to the input parameters. Correct segmentation of the brain appears to be the most

  13. Intraoperative 3 tesla magnetic resonance imaging: our experience in tumors.

    PubMed

    García-Baizán, A; Tomás-Biosca, A; Bartolomé Leal, P; Domínguez, P D; García de Eulate Ruiz, R; Tejada, S; Zubieta, J L

    To report our experience in the use of 3 tesla intraoperative magnetic resonance imaging (MRI) in neurosurgical procedures for tumors, and to evaluate the criteria for increasing the extension of resection. This retrospective study included all consecutive intraoperative MRI studies done for neuro-oncologic disease in the first 13 months after the implementation of the technique. We registered possible immediate complications, the presence of tumor remnants, and whether the results of the intraoperative MRI study changed the surgical management. We recorded the duration of surgery in all cases. The most common tumor was recurrent glioblastoma, followed by primary glioblastoma and metastases. Complete resection was achieved in 28%, and tumor remnants remained in 72%. Intraoperative MRI enabled neurosurgeons to improve the extent of the resection in 85% of cases. The mean duration of surgery was 390±122minutes. Intraoperative MRI using a strong magnetic field (3 teslas) is a valid new technique that enables precise study of the tumor resection to determine whether the resection can be extended without damaging eloquent zones. Although the use of MRI increases the duration of surgery, the time required decreases as the team becomes more familiar with the technique. Copyright © 2018 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Intraoperative indocyanine green videoangiography for spinal vascular lesions: case report.

    PubMed

    Murakami, Tomohiro; Koyanagi, Izumi; Kaneko, Takahisa; Iihoshi, Satoshi; Houkin, Kiyohiro

    2011-03-01

    In surgery of spinal vascular lesions such as spinal arteriovenous fistula or vascular tumors, assessment of feeding arteries and draining veins is important. Intraoperative digital subtraction angiography is useful but is invasive and sometimes technically demanding. Near-infrared indocyanine green (ICG) videoangiography is less invasive and has been reported as an intraoperative diagnosis of arterial patency during clipping surgery of cerebral aneurysms or bypass surgeries. We present our experience with intraoperative ICG videoangiography in 3 cases of spinal vascular lesions. Two patients had spinal arteriovenous fistula (perimedullary, n = 1; dural, n = 1), and 1 patient had spinal cord hemangioblastoma at the thoracic or thoracolumbar level. The surgical microscope was an OPMI Pentero (Carl Zeiss, Oberkochen, Germany). After laminectomy and opening of the dura, ICG (5 mg) was injected intravenously. The ICG angiography clearly demonstrated feeding and draining vessels. The ICG findings greatly helped successful interruption of arteriovenous fistula and total removal of the tumor. Intraoperative ICG videoangiography for spinal vascular lesions was useful by providing information on vascular dynamics directly. However, the diagnostic area is limited to the field of the surgical microscope. Although intraoperative digital subtraction angiography is still needed in cases of complex spinal vascular lesions, ICG videoangiography will be an important diagnostic modality in the field of spinal vascular surgeries.

  15. Recent advances in intensity modulated radiotherapy and proton therapy for esophageal cancer.

    PubMed

    Xi, Mian; Lin, Steven H

    2017-07-01

    Radiotherapy is an important component of the standard of care for esophageal cancer. In the past decades, significant improvements in the planning and delivery of radiation techniques have led to better dose conformity to the target volume and improved normal tissue sparing. Areas covered: This review focuses on the advances in radiotherapy techniques and summarizes the availably dosimetric and clinical outcomes of intensity-modulated radiation therapy (IMRT), volumetric modulated arc therapy, proton therapy, and four-dimensional radiotherapy for esophageal cancer, and discusses the challenges and future development of proton therapy. Expert commentary: Although three-dimensional conformal radiotherapy is the standard radiotherapy technique in esophageal cancer, the retrospectively comparative studies strongly suggest that the dosimetric advantage of IMRT over three-dimensional conformal radiotherapy can translate into improved clinical outcomes, despite the lack of prospective randomized evidence. As a novel form of conventional IMRT technique, volumetric modulated arc therapy can produce equivalent or superior dosimetric quality with significantly higher treatment efficiency in esophageal cancer. Compared with photon therapy, proton therapy has the potential to achieve further clinical improvement due to their physical properties; however, prospective clinical data, long-term results, and cost-effectiveness are needed.

  16. Planning Target Margin Calculations for Prostate Radiotherapy Based on Intrafraction and Interfraction Motion Using Four Localization Methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beltran, Chris; Herman, Michael G.; Davis, Brian J.

    2008-01-01

    Purpose: To determine planning target volume (PTV) margins for prostate radiotherapy based on the internal margin (IM) (intrafractional motion) and the setup margin (SM) (interfractional motion) for four daily localization methods: skin marks (tattoo), pelvic bony anatomy (bone), intraprostatic gold seeds using a 5-mm action threshold, and using no threshold. Methods and Materials: Forty prostate cancer patients were treated with external radiotherapy according to an online localization protocol using four intraprostatic gold seeds and electronic portal images (EPIs). Daily localization and treatment EPIs were obtained. These data allowed inter- and intrafractional analysis of prostate motion. The SM for the fourmore » daily localization methods and the IM were determined. Results: A total of 1532 fractions were analyzed. Tattoo localization requires a SM of 6.8 mm left-right (LR), 7.2 mm inferior-superior (IS), and 9.8 mm anterior-posterior (AP). Bone localization requires 3.1, 8.9, and 10.7 mm, respectively. The 5-mm threshold localization requires 4.0, 3.9, and 3.7 mm. No threshold localization requires 3.4, 3.2, and 3.2 mm. The intrafractional prostate motion requires an IM of 2.4 mm LR, 3.4 mm IS and AP. The PTV margin using the 5-mm threshold, including interobserver uncertainty, IM, and SM, is 4.8 mm LR, 5.4 mm IS, and 5.2 mm AP. Conclusions: Localization based on EPI with implanted gold seeds allows a large PTV margin reduction when compared with tattoo localization. Except for the LR direction, bony anatomy localization does not decrease the margins compared with tattoo localization. Intrafractional prostate motion is a limiting factor on margin reduction.« less

  17. Recommendations for the use of radiotherapy in nodal lymphoma.

    PubMed

    Hoskin, P J; Díez, P; Williams, M; Lucraft, H; Bayne, M

    2013-01-01

    These guidelines have been developed to define the use of radiotherapy for lymphoma in the current era of combined modality treatment taking into account increasing concern over the late side-effects associated with previous radiotherapy. The role of reduced volume and reduced doses is addressed, integrating modern imaging with three-dimensional planning and advanced techniques of treatment delivery. Both wide-field and involved-field techniques have now been supplanted by the use of defined volumes based on node involvement shown on computed tomography (CT) and positron emission tomography (PET) imaging and applying the International Commission on Radiation Units and Measurements concepts of gross tumour volume (GTV), clinical target volume (CTV) and planning target volume (PTV). The planning of lymphoma patients for radical radiotherapy should now be based upon contrast enhanced 3 mm contiguous CT with three-dimensional definition of volumes using the convention of GTV, CTV and PTV. The involved-site radiotherapy concept defines the CTV based on the PET-defined pre-chemotherapy sites of involvement with an expansion in the cranio-caudal direction of lymphatic spread by 1.5 cm, constrained to tissue planes such as bone, muscle and air cavities. The margin allows for uncertainties in PET resolution, image registration and changes in patient positioning and shape. There is increasing evidence in both Hodgkin and non-Hodgkin lymphoma that traditional doses are higher than necessary for disease control and related to the incidence of late effects. No more than 30 Gy for Hodgkin and aggressive non-Hodgkin lymphoma and 24 Gy for indolent lymphomas is recommended; lower doses of 20 Gy in combination therapy for early-stage low-risk Hodgkin lymphoma may be sufficient. As yet there are no large datasets validating the use of involved-site radiotherapy; these will emerge from the current generation of clinical trials. Radiotherapy remains the most effective single

  18. Intraoperative CT in the assessment of posterior wall acetabular fracture stability.

    PubMed

    Cunningham, Brian; Jackson, Kelly; Ortega, Gil

    2014-04-01

    Posterior wall acetabular fractures that involve 10% to 40% of the posterior wall may or may not require an open reduction and internal fixation. Dynamic stress examination of the acetabular fracture under fluoroscopy has been used as an intraoperative method to assess joint stability. The aim of this study was to demonstrate the value of intraoperative ISO computed tomography (CT) examination using the Siemens ISO-C imaging system (Siemens Corp, Malvern, Pennsylvania) in the assessment of posterior wall acetabular fracture stability during stress examination under anesthesia. In 5 posterior wall acetabular fractures, standard fluoroscopic images (including anteroposterior pelvis and Judet radiographs) with dynamic stress examinations were compared with the ISO-C CT imaging system to assess posterior wall fracture stability during stress examination. After review of standard intraoperative fluoroscopic images under dynamic stress examination, all 5 cases appeared to demonstrate posterior wall stability; however, when the intraoperative images from the ISO-C CT imaging system demonstrated that 1 case showed fracture instability of the posterior wall segment during stress examination, open reduction and internal fixation was performed. The use of intraoperative ISO CT imaging has shown an initial improvement in the surgeon's ability to assess the intraoperative stability of posterior wall acetabular fractures during stress examination when compared with standard fluoroscopic images. Copyright 2014, SLACK Incorporated.

  19. Intraoperative definition of bottom-of-sulcus dysplasia using intraoperative ultrasound and single depth electrode recording - A technical note.

    PubMed

    Miller, Dorothea; Carney, Patrick; Archer, John S; Fitt, Gregory J; Jackson, Graeme D; Bulluss, Kristian J

    2018-02-01

    Bottom of sulcus dysplasias (BOSDs) are localized focal cortical dysplasias (FCDs) centred on the bottom of a sulcus that can be highly epileptogenic, but difficult to delineate intraoperatively. We report on a patient with refractory epilepsy due to a BOSD, successfully resected with the aid of a multimodal surgical approach using neuronavigation based on MRI and PET, intraoperative ultrasound (iUS) and electrocorticography (ECoG) using depth electrodes. The lesion could be visualized on iUS showing an increase in echogenicity at the grey-white matter junction. IUS demonstrated the position of the depth electrode in relation to the lesion. Depth electrode recording showed almost continuous spiking. Thus, intraoperative imaging and electrophysiology helped confirm the exact location of the lesion. Post-resection ultrasound demonstrated the extent of the resection and depth electrode recording did not show any epileptiform activity. Thus, both techniques helped assess completeness of resection. The patient has been seizure free since surgery. Using a multimodal approach including iUS and ECoG is a helpful adjunct in surgery for BOSD and may improve seizure outcome. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Utility of Intraoperative Neuromonitoring during Minimally Invasive Fusion of the Sacroiliac Joint.

    PubMed

    Woods, Michael; Birkholz, Denise; MacBarb, Regina; Capobianco, Robyn; Woods, Adam

    2014-01-01

    Study Design. Retrospective case series. Objective. To document the clinical utility of intraoperative neuromonitoring during minimally invasive surgical sacroiliac joint fusion for patients diagnosed with sacroiliac joint dysfunction (as a direct result of sacroiliac joint disruptions or degenerative sacroiliitis) and determine stimulated electromyography thresholds reflective of favorable implant position. Summary of Background Data. Intraoperative neuromonitoring is a well-accepted adjunct to minimally invasive pedicle screw placement. The utility of intraoperative neuromonitoring during minimally invasive surgical sacroiliac joint fusion using a series of triangular, titanium porous plasma coated implants has not been evaluated. Methods. A medical chart review of consecutive patients treated with minimally invasive surgical sacroiliac joint fusion was undertaken at a single center. Baseline patient demographics and medical history, intraoperative electromyography thresholds, and perioperative adverse events were collected after obtaining IRB approval. Results. 111 implants were placed in 37 patients. Sensitivity of EMG was 80% and specificity was 97%. Intraoperative neuromonitoring potentially avoided neurologic sequelae as a result of improper positioning in 7% of implants. Conclusions. The results of this study suggest that intraoperative neuromonitoring may be a useful adjunct to minimally invasive surgical sacroiliac joint fusion in avoiding nerve injury during implant placement.

  1. Intraoperative Clinical Decision Support for Anesthesia: A Narrative Review of Available Systems.

    PubMed

    Nair, Bala G; Gabel, Eilon; Hofer, Ira; Schwid, Howard A; Cannesson, Maxime

    2017-02-01

    With increasing adoption of anesthesia information management systems (AIMS), there is growing interest in utilizing AIMS data for intraoperative clinical decision support (CDS). CDS for anesthesia has the potential for improving quality of care, patient safety, billing, and compliance. Intraoperative CDS can range from passive and post hoc systems to active real-time systems that can detect ongoing clinical issues and deviations from best practice care. Real-time CDS holds the most promise because real-time alerts and guidance can drive provider behavior toward evidence-based standardized care during the ongoing case. In this review, we describe the different types of intraoperative CDS systems with specific emphasis on real-time systems. The technical considerations in developing and implementing real-time CDS are systematically covered. This includes the functional modules of a CDS system, development and execution of decision rules, and modalities to alert anesthesia providers concerning clinical issues. We also describe the regulatory aspects that affect development, implementation, and use of intraoperative CDS. Methods and measures to assess the effectiveness of intraoperative CDS are discussed. Last, we outline areas of future development of intraoperative CDS, particularly the possibility of providing predictive and prescriptive decision support.

  2. Disparities between resident and attending surgeon perceptions of intraoperative teaching.

    PubMed

    Butvidas, Lynn D; Anderson, Cheryl I; Balogh, Daniel; Basson, Marc D

    2011-03-01

    This study aimed to assess attending surgeon and resident recall of good and poor intraoperative teaching experiences and how often these experiences occur at present. By web-based survey, we asked US surgeons and residents to describe their best and worst intraoperative teaching experiences during training and how often 26 common intraoperative teaching behaviors occur in their current environment. A total of 346 residents and 196 surgeons responded (51 programs; 26 states). Surgeons and residents consistently identified trainee autonomy, teacher confidence, and communication as positive, while recalling negatively contemptuous, arrogant, accusatory, or uncommunicative teachers. Residents described intraoperative teaching behaviors by faculty as substantially less frequent than faculty self-reports. Neither sex nor seniority explained these results, although women reported communicative behaviors more frequently than men. Although veteran surgeons and current trainees agree on what constitutes effective and ineffective teaching in the operating room, they disagree on how often these behaviors occur, leaving substantial room for improvement. Published by Elsevier Inc.

  3. Perspectives on the combination of radiotherapy and targeted therapy with DNA repair inhibitors in the treatment of pancreatic cancer

    PubMed Central

    Yang, Shih-Hung; Kuo, Ting-Chun; Wu, Hsu; Guo, Jhe-Cyuan; Hsu, Chiun; Hsu, Chih-Hung; Tien, Yu-Wen; Yeh, Kun-Huei; Cheng, Ann-Lii; Kuo, Sung-Hsin

    2016-01-01

    Pancreatic cancer is highly lethal. Current research that combines radiation with targeted therapy may dramatically improve prognosis. Cancerous cells are characterized by unstable genomes and activation of DNA repair pathways, which are indicated by increased phosphorylation of numerous factors, including H2AX, ATM, ATR, Chk1, Chk2, DNA-PKcs, Rad51, and Ku70/Ku80 heterodimers. Radiotherapy causes DNA damage. Cancer cells can be made more sensitive to the effects of radiation (radiosensitization) through inhibition of DNA repair pathways. The synergistic effects, of two or more combined non-lethal treatments, led to co-administration of chemotherapy and radiosensitization in BRCA-defective cells and patients, with promising results. ATM/Chk2 and ATR/Chk1 pathways are principal regulators of cell cycle arrest, following DNA double-strand or single-strand breaks. DNA double-stranded breaks activate DNA-dependent protein kinase, catalytic subunit (DNA-PKcs). It forms a holoenzyme with Ku70/Ku80 heterodimers, called DNA-PK, which catalyzes the joining of nonhomologous ends. This is the primary repair pathway utilized in human cells after exposure to ionizing radiation. Radiosensitization, induced by inhibitors of ATM, ATR, Chk1, Chk2, Wee1, PP2A, or DNA-PK, has been demonstrated in preclinical pancreatic cancer studies. Clinical trials are underway. Development of agents that inhibit DNA repair pathways to be clinically used in combination with radiotherapy is warranted for the treatment of pancreatic cancer. PMID:27621574

  4. Analysis of FET-PET imaging for target volume definition in patients with gliomas treated with conformal radiotherapy.

    PubMed

    Rieken, Stefan; Habermehl, Daniel; Giesel, Frederik L; Hoffmann, Christoph; Burger, Ute; Rief, Harald; Welzel, Thomas; Haberkorn, Uwe; Debus, Jürgen; Combs, Stephanie E

    2013-12-01

    Modern radiotherapy (RT) techniques such as stereotactic RT, intensity-modulated RT, or particle irradiation allow local dose escalation with simultaneous sparing of critical organs. Several trials are currently investigating their benefit in glioma reirradiation and boost irradiation. Target volume definition is of critical importance especially when steep dose gradient techniques are employed. In this manuscript we investigate the impact of O-(2-(F-18)fluoroethyl)-l-tyrosine-positron emission tomography/computer tomography (FET-PET/CT) on target volume definition in low and high grade glioma patients undergoing either first or re-irradiation with particles. We investigated volumetric size and uniformity of magnetic resonance imaging (MRI)- vs. FET-PET/CT-derived gross tumor volumes (GTVs) and planning target volumes (PTVs) of 41 glioma patients. Clinical cases are presented to demonstrate potential benefits of integrating FET-PET/CT-planning into daily routine. Integrating FET-uptake into the delineation of GTVs yields larger volumes. Combined modality-derived PTVs are significantly enlarged in high grade glioma patients and in case of primary RT. The congruence of MRI and FET signals for the identification of glioma GTVs is poor with mean uniformity indices of 0.39. MRI-based PTVs miss 17% of FET-PET/CT-based GTVs. Non significant alterations were detected in low grade glioma patients and in those undergoing reirradiation. Target volume definition for malignant gliomas during initial RT may yield significantly differing results depending upon the imaging modality, which the contouring process is based upon. The integration of both MRI and FET-PET/CT may help to improve GTV coverage by avoiding larger incongruences between physical and biological imaging techniques. In low grade gliomas and in cases of reirradiation, more studies are needed in order to investigate a potential benefit of FET-PET/CT for planning of RT. Copyright © 2013 Elsevier Ireland Ltd. All

  5. Postoperative Infection in the Setting of Massive Intraoperative Blood Loss.

    PubMed

    Leylek, Melike; Poliquin, Vanessa; Al-Wazzan, Ahmad; Dean, Erin; Altman, Alon D

    2016-12-01

    To determine the local rates of massive intraoperative blood loss and subsequent infectious morbidity for patients undergoing gynaecologic laparotomy. We performed a retrospective chart review of all patients undergoing gynaecologic laparotomy between January 1, 2013 and December 31, 2013 to identify cases of massive intraoperative blood loss (defined as ≥1 L estimated intraoperative blood loss, a postoperative reduction in hemoglobin concentration of ≥40 g/L, or a perioperative blood transfusion). For cases meeting these criteria, we abstracted further data to assess the rate of postoperative infectious morbidity (defined as a positive wound swab culture, positive urine culture, or satisfying the 1991 criteria for systemic inflammatory response syndrome). The rate of massive intraoperative blood loss was 13.5% (n = 69). The average age in this cohort was 50.4 years (range 18-84 years) and the average BMI was 27.9 kg/m 2 . Perioperative transfusion was required in 31.9% (n = 22). Notably, 26.1% of patients (n = 18) met one of our primary endpoints for postoperative infectious morbidity. A further 10.1% (n = 7) had morbidities including hyponatremia, wound dehiscence, intra-abdominal abscess, positive blood cultures, acute respiratory distress syndrome, myocardial infarction, intensive care unit admission, or death. Our rate of massive intraoperative blood loss during gynaecologic laparotomy was found to be 13.5%, and our rate of postoperative infectious morbidity subsequent to massive intraoperative blood loss was 26.1%. Copyright © 2016 The Society of Obstetricians and Gynaecologists of Canada/La Société des obstétriciens et gynécologues du Canada. Published by Elsevier Inc. All rights reserved.

  6. Measurement of intraoperative parathyroid hormone predicts long-term operative success.

    PubMed

    Westerdahl, Johan; Lindblom, Pia; Bergenfelz, Anders

    2002-02-01

    A decrease in the intraoperative parathyroid hormone (PTH) level predicts long-term operative success. A case series of consecutive patients undergoing parathyroidectomy with intraoperative PTH measurement. A university hospital. One hundred two patients with sporadic primary hyperparathyroidism underwent parathyroidectomy according to the principles of unilateral exploration with intraoperative PTH measurement. Longitudinal effects on levels of serum calcium and PTH. In 94 of 98 patients who underwent primary exploration because of a solitary adenoma, intraoperative PTH decreased at least 60% 15 minutes after gland excision. The 4 cases in which PTH fell to less than 60% were classified as false negatives. Patients examined for multiglandular disease (n = 4) were correctly predicted not to have an adenoma. Twenty-two patients (22%) were unavailable for 5-year follow-up. These patients were followed up for 2 months to 48 months (median, 24 months), and none developed recurrent primary hyperparathyroidism. Of the remaining 80 patients (78%), all but 1 patient had normal or slightly decreased serum calcium levels (mean +/- SD, 9.24 +/- 0.4 mg/dL [2.31 +/- 0.10 mmol/L]) at 5-year follow-up. One patient with hypercalcemia (10.6 mg/dL [2.65 mmol/L]) was interpreted to have developed renal failure with secondary hyperparathyroidism. Thirty-four patients had elevated serum PTH levels at least once during the postoperative study period, with normal or slightly decreased calcium concentrations. The prediction of late postoperative normocalcemia by means of intraoperative PTH measurement had an overall accuracy of 95%. The measurement of intraoperative PTH during surgery for primary hyperparathyroidism accurately differentiates between single- and multiple-gland disease and ensures good long-term results.

  7. Target motion tracking in MRI-guided transrectal robotic prostate biopsy.

    PubMed

    Tadayyon, Hadi; Lasso, Andras; Kaushal, Aradhana; Guion, Peter; Fichtinger, Gabor

    2011-11-01

    MRI-guided prostate needle biopsy requires compensation for organ motion between target planning and needle placement. Two questions are studied and answered in this paper: 1) is rigid registration sufficient in tracking the targets with an error smaller than the clinically significant size of prostate cancer and 2) what is the effect of the number of intraoperative slices on registration accuracy and speed? we propose multislice-to-volume registration algorithms for tracking the biopsy targets within the prostate. Three orthogonal plus additional transverse intraoperative slices are acquired in the approximate center of the prostate and registered with a high-resolution target planning volume. Both rigid and deformable scenarios were implemented. Both simulated and clinical MRI-guided robotic prostate biopsy data were used to assess tracking accuracy. average registration errors in clinical patient data were 2.6 mm for the rigid algorithm and 2.1 mm for the deformable algorithm. rigid tracking appears to be promising. Three tracking slices yield significantly high registration speed with an affordable error.

  8. [Radiotherapy in cancers of the oesophagus, the gastric cardia and the stomach].

    PubMed

    Créhange, G; Huguet, F; Quero, L; N'Guyen, T V; Mirabel, X; Lacornerie, T

    2016-09-01

    Localized oesophageal and gastric cancers have a poor prognosis. In oesophageal cancer, external radiotherapy combined with concomitant chemotherapy is accepted as part of the therapeutic armamentarium in a curative intent in the preoperative setting for resectable tumours; or without surgery in inoperable patients or non-resectable tumours due to wide local and/or regional extension. Data from the literature show conflicting results with no clinical evidence in favour of either a unique dose protocol or consensual target volume definition in the setting of exclusive chemoradiation. In the preoperative setting, chemoradiotherapy has become the standard in oesophageal cancer, even though there is no evidence that surgery may be beneficial in locally advanced tumours that respond to radiotherapy and chemotherapy. The main cause of failure after exclusive chemoradiotherapy in oesophageal cancer is locoregional relapse suggesting that doses and volumes usually considered may be inadequate. In gastric cancer, radiotherapy may be indicated postoperatively in patients with resected tumours that include less than D2 lymph node dissection or in the absence of perioperative chemotherapy. Preoperative chemoradiotherapy in gastric cancers is still under investigation. The evolving techniques of external radiotherapy, such as image-guided radiotherapy (IMRT) and volumetric modulated arctherapy (VMAT) have reduced the volume of lung and heart exposed to radiation, which seems to have diminished radiotherapy-related morbi-mortality rates. Given this, quality assurance for radiotherapy and protocols for radiotherapy delivery must be better standardized. This article on the indications for radiotherapy and the techniques used in oesophageal and gastric cancers is included in a special issue dedicated to national recommendations from the French society of radiation oncology (SFRO) on radiotherapy indications, planning, dose prescription, and techniques of radiotherapy delivery

  9. [Clinical evaluation of heavy-particle radiotherapy using dose volume histogram (DVH)].

    PubMed

    Terahara, A; Nakano, T; Tsujii, H

    1998-01-01

    Radiotherapy with heavy particles such as proton and heavy-charged particles is a promising modality for treatment of localized malignant tumors because of the good dose distribution. A dose calculation and radiotherapy planning system which is essential for this kind of treatment has been developed in recent years. It has the capability to compute the dose volume histogram (DVH) which contains dose-volume information for the target volume and other interesting volumes. Recently, DVH is commonly used to evaluate and compare dose distributions in radiotherapy with both photon and heavy particles, and it shows that a superior dose distribution is obtained in heavy particle radiotherapy. DVH is also utilized for the evaluation of dose distribution related to clinical outcomes. Besides models such as normal tissue complication probability (NTCP) and tumor control probability (TCP), which can be calculated from DVH are proposed by several authors, they are applied to evaluate dose distributions themselves and to evaluate them in relation to clinical results. DVH is now a useful and important tool, but further studies are needed to use DVH and these models practically for clinical evaluation of heavy-particle radiotherapy.

  10. Radioguided surgery and the GOSTT concept: From pre-operative image and intraoperative navigation to image-assisted excision.

    PubMed

    Bowles, H; Sánchez, N; Tapias, A; Paredes, P; Campos, F; Bluemel, C; Valdés Olmos, R A; Vidal-Sicart, S

    Radio-guided surgery has been developed for application in those disease scheduled for surgical management, particularly in areas of complex anatomy. This is based on the use of pre-operative scintigraphic planar, tomographic and fused SPECT/CT images, and the possibility of 3D reconstruction for the subsequent intraoperative locating of active lesions using handheld devices (detection probes, gamma cameras, etc.). New tracers and technologies have also been incorporated into these surgical procedures. The combination of visual and acoustic signals during the intraoperative procedure has become possible with new portable imaging modalities. In daily practice, the images offered by these techniques and devices combine perioperative nuclear medicine imaging with the superior resolution of additional optical guidance in the operating room. In many ways they provide real-time images, allowing accurate guidance during surgery, a reduction in the time required for tissue location and an anatomical environment for surgical recognition. All these approaches have been included in the concept known as (radio) Guided intraOperative Scintigraphic Tumour Targeting (GOSTT). This article offers a general view of different nuclear medicine and allied technologies used for several GOSTT procedures, and illustrates the crossing of technological frontiers in radio-guided surgery. Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  11. Usefulness of intraoperative ultra low-field magnetic resonance imaging in glioma surgery.

    PubMed

    Senft, Christian; Seifert, Volker; Hermann, Elvis; Franz, Kea; Gasser, Thomas

    2008-10-01

    The aim of this study was to demonstrate the usefulness of a mobile, intraoperative 0.15-T magnetic resonance imaging (MRI) scanner in glioma surgery. We analyzed our prospectively collected database of patients with glial tumors who underwent tumor resection with the use of an intraoperative ultra low-field MRI scanner (PoleStar N-20; Odin Medical Technologies, Yokneam, Israel/Medtronic, Louisville, CO). Sixty-three patients with World Health Organization Grade II to IV tumors were included in the study. All patients were subjected to postoperative 1.5-T imaging to confirm the extent of resection. Intraoperative image quality was sufficient for navigation and resection control in both high- and low-grade tumors. Primarily enhancing tumors were best detected on T1-weighted imaging, whereas fluid-attenuated inversion recovery sequences proved best for nonenhancing tumors. Intraoperative resection control led to further tumor resection in 12 (28.6%) of 42 patients with contrast-enhancing tumors and in 10 (47.6%) of 21 patients with noncontrast-enhancing tumors. In contrast-enhancing tumors, further resection led to an increased rate of complete tumor resection (71.2 versus 52.4%), and the surgical goal of gross total removal or subtotal resection was achieved in all cases (100.0%). In patients with noncontrast-enhancing tumors, the surgical goal was achieved in 19 (90.5%) of 21 cases, as intraoperative MRI findings were inconsistent with postoperative high-field imaging in 2 cases. The use of the PoleStar N-20 intraoperative ultra low-field MRI scanner helps to evaluate the extent of resection in glioma surgery. Further tumor resection after intraoperative scanning leads to an increased rate of complete tumor resection, especially in patients with contrast-enhancing tumors. However, in noncontrast- enhancing tumors, the intraoperative visualization of a complete resection seems less specific, when compared with postoperative 1.5-T MRI.

  12. Operative record using intraoperative digital data in neurosurgery.

    PubMed

    Houkin, K; Kuroda, S; Abe, H

    2000-01-01

    The purpose of this study was to develop a new method for more efficient and accurate operative records using intra-operative digital data in neurosurgery, including macroscopic procedures and microscopic procedures under an operating microscope. Macroscopic procedures were recorded using a digital camera and microscopic procedures were also recorded using a microdigital camera attached to an operating microscope. Operative records were then recorded digitally and filed in a computer using image retouch software and database base software. The time necessary for editing of the digital data and completing the record was less than 30 minutes. Once these operative records are digitally filed, they are easily transferred and used as database. Using digital operative records along with digital photography, neurosurgeons can document their procedures more accurately and efficiently than by the conventional method (handwriting). A complete digital operative record is not only accurate but also time saving. Construction of a database, data transfer and desktop publishing can be achieved using the intra-operative data, including intra-operative photographs.

  13. An electromechanical, patient positioning system for head and neck radiotherapy

    NASA Astrophysics Data System (ADS)

    Ostyn, Mark; Dwyer, Thomas; Miller, Matthew; King, Paden; Sacks, Rachel; Cruikshank, Ross; Rosario, Melvin; Martinez, Daniel; Kim, Siyong; Yeo, Woon-Hong

    2017-09-01

    In cancer treatment with radiation, accurate patient setup is critical for proper dose delivery. Improper arrangement can lead to disease recurrence, permanent organ damage, or lack of disease control. While current immobilization equipment often helps for patient positioning, manual adjustment is required, involving iterative, time-consuming steps. Here, we present an electromechanical robotic system for improving patient setup in radiotherapy, specifically targeting head and neck cancer. This positioning system offers six degrees of freedom for a variety of applications in radiation oncology. An analytical calculation of inverse kinematics serves as fundamental criteria to design the system. Computational mechanical modeling and experimental study of radiotherapy compatibility and x-ray-based imaging demonstrates the device feasibility and reliability to be used in radiotherapy. An absolute positioning accuracy test in a clinical treatment room supports the clinical feasibility of the system.

  14. Cost analysis of prophylactic intraoperative cystoscopic ureteral stents in gynecologic surgery.

    PubMed

    Fanning, James; Fenton, Bradford; Jean, Geraldine Marie; Chae, Clara

    2011-12-01

    Prophylactic intraoperative ureteral stent placement is performed to decrease operative ureteric injury, though few data are available on the effectiveness of this procedure, and no data are available on its cost. To analyze the cost of prophylactic intraoperative cystoscopic ureteral stents in gynecologic surgery. All cases of prophylactic ureteral stent placement performed in gynecologic surgery during a 1-year period were identified and retrospectively reviewed through the electronic medical records database of Summa Health System. Costs were obtained through the Healthcare Cost Accounting System. The principles of cost-effective analysis were used (ie, explicit and detailed descriptions of costs and cost-effectiveness statistics). Importantly, we evaluated cost and not charges or financial model estimates. In addition, we obtained the contribution margins (ie, the hospital's net profit or loss) for prophylactic ureteral stent placement. Other gynecologic procedures were also analyzed. Among 792 major inpatient gynecologic procedures, 18 cases of prophylactic intraoperative ureteral stents were identified. Median costs were as follows: additional cost of prophylactic intraoperative ureteral stenting, $1580; additional cost of surgical resources, $770; cost of ureteral catheters, $427; cost of surgeons, $383. The contribution margins per case for various gynecologic surgical procedures were as follows: oophorectomy, $2804 profit; abdominal hysterectomy, $2649 profit; laparoscopically assisted vaginal hysterectomy (LAVH), $1760 profit. When intraoperative ureteral stenting was added, the contribution margins changed to the following: oophorectomy, $782 profit; abdominal hysterectomy, $627 profit; LAVH, $262 loss. Overall, the contribution margin profit was decreased by about 85%, from $2400 to $380. Prophylactic intraoperative ureteral stenting in gynecologic surgery decreases a hospital's contribution margin. Because of the expense of this procedure, as well as

  15. Real-time image guidance in laparoscopic liver surgery: first clinical experience with a guidance system based on intraoperative CT imaging.

    PubMed

    Kenngott, Hannes G; Wagner, Martin; Gondan, Matthias; Nickel, Felix; Nolden, Marco; Fetzer, Andreas; Weitz, Jürgen; Fischer, Lars; Speidel, Stefanie; Meinzer, Hans-Peter; Böckler, Dittmar; Büchler, Markus W; Müller-Stich, Beat P

    2014-03-01

    Laparoscopic liver surgery is particularly challenging owing to restricted access, risk of bleeding, and lack of haptic feedback. Navigation systems have the potential to improve information on the exact position of intrahepatic tumors, and thus facilitate oncological resection. This study aims to evaluate the feasibility of a commercially available augmented reality (AR) guidance system employing intraoperative robotic C-arm cone-beam computed tomography (CBCT) for laparoscopic liver surgery. A human liver-like phantom with 16 target fiducials was used to evaluate the Syngo iPilot(®) AR system. Subsequently, the system was used for the laparoscopic resection of a hepatocellular carcinoma in segment 7 of a 50-year-old male patient. In the phantom experiment, the AR system showed a mean target registration error of 0.96 ± 0.52 mm, with a maximum error of 2.49 mm. The patient successfully underwent the operation and showed no postoperative complications. The use of intraoperative CBCT and AR for laparoscopic liver resection is feasible and could be considered an option for future liver surgery in complex cases.

  16. Stereotactic fractionated radiotherapy for the treatment of benign meningiomas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Candish, Charles; McKenzie, Michael; Clark, Brenda G.

    Purpose: To assess the use of stereotactic fractionated radiotherapy (SRT) for the treatment of meningiomas. Methods and Materials: Between April 1999 and October 2004, 38 patients underwent SRT. Of 34 patients (36 tumors) assessed, the median age was 53 years. The indication was primary treatment in 26 cases (no histology) and postoperative in 10 cases. The most common sites were cavernous sinus (17), optic nerve (6), and cerebellopontine angle (5). The median gross target volume and planning target volume were 8.9 cm{sup 3} and 18.9 cm{sup 3}, respectively. Stereotactic treatment was delivered with 6-MV photons with static conformal fields (custom-mademore » blocks, 9 patients, and micromultileaf collimator, 25 patients). Median number of fields was six. The median dose prescribed was 50 Gy (range, 45-50.4 Gy) in 28 fractions. The median homogeneity and conformality indices were 1.1 and 1.79, respectively. Results: Treatment was well tolerated. Median follow-up was 26 months with 100% progression-free survival. One patient developed an area of possible radionecrosis related to previous radiotherapy, and 2 men developed mild hypogonadism necessitating testosterone replacement. The vision of 5 of 6 patients with optic pathway meningiomas improved or remained static. Conclusions: Stereotactic fractionated radiotherapy for the treatment of meningiomas is practical, and with early follow-up, seems to be effective.« less

  17. Reirradiation for recurrent head and neck cancers using charged particle or photon radiotherapy.

    PubMed

    Yamazaki, Hideya; Demizu, Yusuke; Okimoto, Tomoaki; Ogita, Mikio; Himei, Kengo; Nakamura, Satoaki; Suzuki, Gen; Yoshida, Ken; Kotsuma, Tadayuki; Yoshioka, Yasuo; Oh, Ryoongjin

    2017-07-01

    To examine the outcomes of reirradiation for recurrent head and neck cancers using different modalities. This retrospective study included 26 patients who received charged particle radiotherapy (CP) and 150 who received photon radiotherapy (117 CyberKnife radiotherapy [CK] and 36 intensity-modulated radiotherapy [IMRT]). Inverse probability of treatment weighting (IPTW) involving propensity scores was used to reduce background selection bias. Higher prescribed doses were used in CP than photon radiotherapy. The 1‑year overall survival (OS) rates were 67.9% for CP and 54.1% for photon radiotherapy (p = 0.15; 55% for CK and 51% for IMRT). In multivariate Cox regression, the significant prognostic factors for better survival were nasopharyngeal cancer, higher prescribed dose, and lower tumor volume. IPTW showed a statistically significant difference between CP and photon radiotherapy (p = 0.04). The local control rates for patients treated with CP and photon radiotherapy at 1 year were 66.9% (range 46.3-87.5%) and 67.1% (range 58.3-75.9%), respectively. A total of 48 patients (27%) experienced toxicity grade ≥3 (24% in the photon radiotherapy group and 46% in the CP group), including 17 patients with grade 5 toxicity. Multivariate analysis revealed that younger age and a larger planning target volume (PTV) were significant risk factors for grade 3 or worse toxicity. CP provided superior survival outcome compared to photon radiotherapy. Tumor volume, primary site (nasopharyngeal), and prescribed dose were identified as survival factors. Younger patients with a larger PTV experienced toxicity grade ≥3.

  18. Left-sided breast cancer irradiation using rotational and fixed-field radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qi, X. Sharon, E-mail: xqi@mednet.ucla.edu; Liu, Tian X.; Liu, Arthur K.

    2014-10-01

    The 3-dimensional conformal radiotherapy (3DCRT) technique is the standard for breast cancer radiotherapy. During treatment planning, not only the coverage of the planning target volume (PTV) but also the minimization of the dose to critical structures, such as the lung, heart, and contralateral breast tissue, need to be considered. Because of the complexity and variations of patient anatomy, more advanced radiotherapy techniques are sometimes desired to better meet the planning goals. In this study, we evaluated external-beam radiation treatment techniques for left breast cancer using various delivery platforms: fixed-field including TomoDirect (TD), static intensity-modulated radiotherapy (sIMRT), and rotational radiotherapy includingmore » Elekta volumetric-modulated arc therapy (VMAT) and tomotherapy helical (TH). A total of 10 patients with left-sided breast cancer who did or did not have positive lymph nodes and were previously treated with 3DCRT/sIMRT to the entire breast were selected, their treatment was planned with Monaco VMAT, TD, and TH. Dosimetric parameters including PTV coverage, organ-at-risk (OAR) sparing, dose-volume histograms, and target minimum/maximum/mean doses were evaluated. It is found that for plans providing comparable PTV coverage, the Elekta VMAT plans were generally more inhomogeneous than the TH and TD plans. For the cases with regional node involvement, the average mean doses administered to the heart were 9.2 (± 5.2) and 8.8 (± 3.0) Gy in the VMAT and TH plans compared with 11.9 (± 6.4) and 11.8 (± 9.2) Gy for the 3DCRT and TD plans, respectively, with slightly higher doses given to the contralateral lung or breast or both. On average, the total monitor units for VMAT plans are 11.6% of those TH plans. Our studies have shown that VMAT and TH plans offer certain dosimetric advantages over fixed-field IMRT plans for advanced breast cancer requiring regional nodal treatment. However, for early-stage breast cancer fixed

  19. Intraoperative Raman Spectroscopy of Soft Tissue Sarcomas

    PubMed Central

    Nguyen, John Q.; Gowani, Zain S.; O’Connor, Maggie; Pence, Isaac J.; Nguyen, The-Quyen; Holt, Ginger E.; Schwartz, Herbert S.; Halpern, Jennifer L.; Mahadevan-Jansen, Anita

    2017-01-01

    Background and Objective Soft tissue sarcomas (STS) are a rare and heterogeneous group of malignant tumors that are often treated through surgical resection. Current intraoperative margin assessment methods are limited and highlight the need for an improved approach with respect to time and specificity. Here we investigate the potential of near-infrared Raman spectroscopy for the intraoperative differentiation of STS from surrounding normal tissue. Materials and Methods In vivo Raman measurements at 785 nm excitation were intraoperatively acquired from subjects undergoing STS resection using a probe based spectroscopy system. A multivariate classification algorithm was developed in order to automatically identify spectral features that can be used to differentiate STS from the surrounding normal muscle and fat. The classification algorithm was subsequently tested using leave-one-subject-out cross-validation. Results With the exclusion of well-differentiated liposarcomas, the algorithm was able to classify STS from the surrounding normal muscle and fat with a sensitivity and specificity of 89.5% and 96.4%, respectively. Conclusion These results suggest that single point near-infrared Raman spectroscopy could be utilized as a rapid and non-destructive surgical guidance tool for identifying abnormal tissue margins in need of further excision. PMID:27454580

  20. Enraged about radiotherapy.

    PubMed Central

    Sikora, K.

    1994-01-01

    The use of radiotherapy in treating breast cancer has meant that many women are able to avoid mastectomy, which is both physically and psychologically damaging. The side effects of radiotherapy, however, are given little attention. Many women have developed brachial plexus injury after radiotherapy for breast cancer, often resulting in severe pain and loss of use of the arm. There is no effective treatment for this injury and little help can be offered. In addition, many of the women did not require radiotherapy of nodal areas. A pressure group has been formed to support these women, to establish the right to compensation, and to ensure that radiotherapy regimens given to future patients will not damage the brachial plexus. Images p188-a PMID:8312773

  1. Intraoperative cyclorotation and pupil centroid shift during LASIK and PRK.

    PubMed

    Narváez, Julio; Brucks, Matthew; Zimmerman, Grenith; Bekendam, Peter; Bacon, Gregory; Schmid, Kristin

    2012-05-01

    To determine the degree of cyclorotation and centroid shift in the x and y axis that occurs intraoperatively during LASIK and photorefractive keratectomy (PRK). Intraoperative cyclorotation and centroid shift were measured in 63 eyes from 34 patients with a mean age of 34 years (range: 20 to 56 years) undergoing either LASIK or PRK. Preoperatively, an iris image of each eye was obtained with the VISX WaveScan Wavefront System (Abbott Medical Optics Inc) with iris registration. A VISX Star S4 (Abbott Medical Optics Inc) laser was later used to measure cyclotorsion and pupil centroid shift at the beginning of the refractive procedure and after flap creation or epithelial removal. The mean change in intraoperative cyclorotation was 1.48±1.11° in LASIK eyes and 2.02±2.63° in PRK eyes. Cyclorotation direction changed by >2° in 21% of eyes after flap creation in LASIK and in 32% of eyes after epithelial removal in PRK. The respective mean intraoperative shift in the x axis and y axis was 0.13±0.15 mm and 0.17±0.14 mm, respectively, in LASIK eyes, and 0.09±0.07 mm and 0.10±0.13 mm, respectively, in PRK eyes. Intraoperative centroid shifts >100 μm in either the x axis or y axis occurred in 71% of LASIK eyes and 55% of PRK eyes. Significant changes in cyclotorsion and centroid shifts were noted prior to surgery as well as intraoperatively with both LASIK and PRK. It may be advantageous to engage iris registration immediately prior to ablation to provide a reference point representative of eye position at the initiation of laser delivery. Copyright 2012, SLACK Incorporated.

  2. Intraoperative language localization in multilingual patients with gliomas.

    PubMed

    Bello, Lorenzo; Acerbi, Francesco; Giussani, Carlo; Baratta, Pietro; Taccone, Paolo; Songa, Valeria; Fava, Marica; Stocchetti, Nino; Papagno, Costanza; Gaini, Sergio M

    2006-07-01

    Intraoperative localization of speech is problematic in patients who are fluent in different languages. Previous studies have generated various results depending on the series of patients studied, the type of language, and the sensitivity of the tasks applied. It is not clear whether languages are mediated by multiple and separate cortical areas or shared by common areas. Globally considered, previous studies recommended performing a multiple intraoperative mapping for all the languages in which the patient is fluent. The aim of this work was to study the feasibility of performing an intraoperative multiple language mapping in a group of multilingual patients with a glioma undergoing awake craniotomy for tumor removal and to describe the intraoperative cortical and subcortical findings in the area of craniotomy, with the final goal to maximally preserve patients' functional language. Seven late, highly proficient multilingual patients with a left frontal glioma were submitted preoperatively to a battery of tests to evaluate oral language production, comprehension, and repetition. Each language was tested serially starting from the first acquired language. Items that were correctly named during these tests were used to build personalized blocks to be used intraoperatively. Language mapping was undertaken during awake craniotomies by the use of an Ojemann cortical stimulator during counting and oral naming tasks. Subcortical stimulation by using the same current threshold was applied during tumor resection, in a back and forth fashion, and the same tests. Cortical sites essential for oral naming were found in 87.5% of patients, those for the first acquired language in one to four sites, those for the other languages in one to three sites. Sites for each language were distinct and separate. Number and location of sites were not predictable, being randomly and widely distributed in the cortex around or less frequently over the tumor area. Subcortical stimulations found

  3. Reducing intraoperative red blood cell unit wastage in a large academic medical center

    PubMed Central

    Whitney, Gina M.; Woods, Marcella C.; France, Daniel J.; Austin, Thomas M.; Deegan, Robert J.; Paroskie, Allison; Booth, Garrett S.; Young, Pampee P.; Dmochowski, Roger R.; Sandberg, Warren S.; Pilla, Michael A.

    2015-01-01

    BACKGROUND The wastage of red blood cell (RBC) units within the operative setting results in significant direct costs to health care organizations. Previous education-based efforts to reduce wastage were unsuccessful at our institution. We hypothesized that a quality and process improvement approach would result in sustained reductions in intraoperative RBC wastage in a large academic medical center. STUDY DESIGN AND METHODS Utilizing a failure mode and effects analysis supplemented with time and temperature data, key drivers of perioperative RBC wastage were identified and targeted for process improvement. RESULTS Multiple contributing factors, including improper storage and transport and lack of accurate, locally relevant RBC wastage event data were identified as significant contributors to ongoing intraoperative RBC unit wastage. Testing and implementation of improvements to the process of transport and storage of RBC units occurred in liver transplant and adult cardiac surgical areas due to their history of disproportionately high RBC wastage rates. Process interventions targeting local drivers of RBC wastage resulted in a significant reduction in RBC wastage (p <0.0001; adjusted odds ratio, 0.24; 95% confidence interval, 0.15–0.39), despite an increase in operative case volume over the period of the study. Studied process interventions were then introduced incrementally in the remainder of the perioperative areas. CONCLUSIONS These results show that a multidisciplinary team focused on the process of blood product ordering, transport, and storage was able to significantly reduce operative RBC wastage and its associated costs using quality and process improvement methods. PMID:26202213

  4. Image Fusion for Radiosurgery, Neurosurgery and Hypofractionated Radiotherapy.

    PubMed

    Inoue, Hiroshi K; Nakajima, Atsushi; Sato, Hiro; Noda, Shin-Ei; Saitoh, Jun-Ichi; Suzuki, Yoshiyuki

    2015-03-01

    Precise target detection is essential for radiosurgery, neurosurgery and hypofractionated radiotherapy because treatment results and complication rates are related to accuracy of the target definition. In skull base tumors and tumors around the optic pathways, exact anatomical evaluation of cranial nerves are important to avoid adverse effects on these structures close to lesions. Three-dimensional analyses of structures obtained with MR heavy T2-images and image fusion with CT thin-sliced sections are desirable to evaluate fine structures during radiosurgery and microsurgery. In vascular lesions, angiography is most important for evaluations of whole structures from feeder to drainer, shunt, blood flow and risk factors of bleeding. However, exact sites and surrounding structures in the brain are not shown on angiography. True image fusions of angiography, MR images and CT on axial planes are ideal for precise target definition. In malignant tumors, especially recurrent head and neck tumors, biologically active areas of recurrent tumors are main targets of radiosurgery. PET scan is useful for quantitative evaluation of recurrences. However, the examination is not always available at the time of radiosurgery. Image fusion of MR diffusion images with CT is always available during radiosurgery and useful for the detection of recurrent lesions. All images are fused and registered on thin sliced CT sections and exactly demarcated targets are planned for treatment. Follow-up images are also able to register on this CT. Exact target changes, including volume, are possible in this fusion system. The purpose of this review is to describe the usefulness of image fusion for 1) skull base, 2) vascular, 3) recurrent target detection, and 4) follow-up analyses in radiosurgery, neurosurgery and hypofractionated radiotherapy.

  5. Image Fusion for Radiosurgery, Neurosurgery and Hypofractionated Radiotherapy

    PubMed Central

    Nakajima, Atsushi; Sato, Hiro; Noda, Shin-ei; Saitoh, Jun-ichi; Suzuki, Yoshiyuki

    2015-01-01

    Precise target detection is essential for radiosurgery, neurosurgery and hypofractionated radiotherapy because treatment results and complication rates are related to accuracy of the target definition. In skull base tumors and tumors around the optic pathways, exact anatomical evaluation of cranial nerves are important to avoid adverse effects on these structures close to lesions. Three-dimensional analyses of structures obtained with MR heavy T2-images and image fusion with CT thin-sliced sections are desirable to evaluate fine structures during radiosurgery and microsurgery. In vascular lesions, angiography is most important for evaluations of whole structures from feeder to drainer, shunt, blood flow and risk factors of bleeding. However, exact sites and surrounding structures in the brain are not shown on angiography. True image fusions of angiography, MR images and CT on axial planes are ideal for precise target definition. In malignant tumors, especially recurrent head and neck tumors, biologically active areas of recurrent tumors are main targets of radiosurgery. PET scan is useful for quantitative evaluation of recurrences. However, the examination is not always available at the time of radiosurgery. Image fusion of MR diffusion images with CT is always available during radiosurgery and useful for the detection of recurrent lesions. All images are fused and registered on thin sliced CT sections and exactly demarcated targets are planned for treatment. Follow-up images are also able to register on this CT. Exact target changes, including volume, are possible in this fusion system. The purpose of this review is to describe the usefulness of image fusion for 1) skull base, 2) vascular, 3) recurrent target detection, and 4) follow-up analyses in radiosurgery, neurosurgery and hypofractionated radiotherapy. PMID:26180676

  6. SU-E-J-76: Incorporation of Ultrasound Elastography in Target Volume Delineation for Partial Breast Radiotherapy Planning: A Comparative Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Juneja, P; Harris, E; Bamber, J

    2014-06-01

    Purpose: There is substantial observer variability in the delineation of target volumes for post-surgical partial breast radiotherapy because the tumour bed has poor x-ray contrast. This variability may result in substantial variations in planned dose distribution. Ultrasound elastography (USE) has an ability to detect mechanical discontinuities and therefore, the potential to image the scar and distortion in breast tissue architecture. The goal of this study was to compare USE techniques: strain elastography (SE), shear wave elastography (SWE) and acoustic radiation force impulse (ARFI) imaging using phantoms that simulate features of the tumour bed, for the purpose of incorporating USE inmore » breast radiotherapy planning. Methods: Three gelatine-based phantoms (10% w/v) containing: a stiff inclusion (gelatine 16% w/v) with adhered boundaries, a stiff inclusion (gelatine 16% w/v) with mobile boundaries and fluid cavity inclusion (to mimic seroma), were constructed and used to investigate the USE techniques. The accuracy of the elastography techniques was quantified by comparing the imaged inclusion with the modelled ground-truth using the Dice similarity coefficient (DSC). For two regions of interest (ROI), the DSC measures their spatial overlap. Ground-truth ROIs were modelled using geometrical measurements from B-mode images. Results: The phantoms simulating stiff scar tissue with adhered and mobile boundaries and seroma were successfully developed and imaged using SE and SWE. The edges of the stiff inclusions were more clearly visible in SE than in SWE. Subsequently, for all these phantoms the measured DSCs were found to be higher for SE (DSCs: 0.91–0.97) than SWE (DSCs: 0.68–0.79) with an average relative difference of 23%. In the case of seroma phantom, DSC values for SE and SWE were similar. Conclusion: This study presents a first attempt to identify the most suitable elastography technique for use in breast radiotherapy planning. Further analysis

  7. Comparison of Intraoperatively Built Custom Linked Seeds Versus Loose Seed Gun Applicator Technique Using Real-Time Intraoperative Planning for Permanent Prostate Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zauls, A. Jason; Ashenafi, Michael S.; Onicescu, Georgiana

    2011-11-15

    Purpose: To report our dosimetric results using a novel push-button seed delivery system that constructs custom links of seeds intraoperatively. Methods and Materials: From 2005 to 2007, 43 patients underwent implantation using a gun applicator (GA), and from 2007 to 2008, 48 patientsunderwent implantation with a novel technique allowing creation of intraoperatively built custom links of seeds (IBCL). Specific endpoint analyses were prostate D90% (pD90%), rV100% > 1.3 cc, and overall time under anesthesia. Results: Final analyses included 91 patients, 43 GA and 48 IBCL. Absolute change in pD90% ({Delta}pD90%) between intraoperative and postoperative plans was evaluated. Using GA method,more » the {Delta}pD90% was -8.1Gy and -12.8Gy for I-125 and Pd-103 implants, respectively. Similarly, the IBCL technique resulted in a {Delta}pD90% of -8.7Gy and -9.8Gy for I-125 and Pd-103 implants, respectively. No statistically significant difference in {Delta}pD90% was found comparing methods. The GA method had two intraoperative and 10 postoperative rV100% >1.3 cc. For IBCL, five intraoperative and eight postoperative plans had rV100% >1.3 cc. For GA, the mean time under anesthesia was 75 min and 87 min for Pd-103 and I-125 implants, respectively. For IBCL, the mean time was 86 and 98 min for Pd-103 and I-125. There was a statistical difference between the methods when comparing mean time under anesthesia. Conclusions: Dosimetrically relevant endpoints were equivalent between the two methods. Currently, time under anesthesia is longer using the IBCL technique but has decreased over time. IBCL is a straightforward brachytherapy technique that can be implemented into clinical practice as an alternative to gun applicators.« less

  8. Lumbar Lordosis of Spinal Stenosis Patients during Intraoperative Prone Positioning

    PubMed Central

    Lee, Su-Keon; Song, Kyung-Sub; Park, Byung-Moon; Lim, Sang-Youn; Jang, Geun; Lee, Beom-Seok; Moon, Seong-Hwan; Lee, Hwan-Mo

    2016-01-01

    Background To evaluate the effect of spondylolisthesis on lumbar lordosis on the OSI (Jackson; Orthopaedic Systems Inc.) frame. Restoration of lumbar lordosis is important for maintaining sagittal balance. Physiologic lumbar lordosis has to be gained by intraoperative prone positioning with a hip extension and posterior instrumentation technique. There are some debates about changing lumbar lordosis on the OSI frame after an intraoperative prone position. We evaluated the effect of spondylolisthesis on lumbar lordosis after an intraoperative prone position. Methods Sixty-seven patients, who underwent spinal fusion at the Department of Orthopaedic Surgery of Gwangmyeong Sungae Hospital between May 2007 and February 2012, were included in this study. The study compared lumbar lordosis on preoperative upright, intraoperative prone and postoperative upright lateral X-rays between the simple stenosis (SS) group and spondylolisthesis group. The average age of patients was 67.86 years old. The average preoperative lordosis was 43.5° (± 14.9°), average intraoperative lordosis was 48.8° (± 13.2°), average postoperative lordosis was 46.5° (± 16.1°) and the average change on the frame was 5.3° (± 10.6°). Results Among all patients, 24 patients were diagnosed with simple spinal stenosis, 43 patients with spondylolisthesis (29 degenerative spondylolisthesis and 14 isthmic spondylolisthesis). Between the SS group and spondylolisthesis group, preoperative lordosis, intraoperative lordosis and postoperative lordosis were significantly larger in the spondylolisthesis group. The ratio of patients with increased lordosis on the OSI frame compared to preoperative lordosis was significantly higher in the spondylolisthesis group. The risk of increased lordosis on frame was significantly higher in the spondylolisthesis group (odds ratio, 3.325; 95% confidence interval, 1.101 to 10.039; p = 0.033). Conclusions Intraoperative lumbar lordosis on the OSI frame with a prone

  9. Simple Carotid-Sparing Intensity-Modulated Radiotherapy Technique and Preliminary Experience for T1-2 Glottic Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosenthal, David I., E-mail: dirosenthal@mdanderson.or; Fuller, Clifton D.; Barker, Jerry L.

    2010-06-01

    Purpose: To investigate the dosimetry and feasibility of carotid-sparing intensity-modulated radiotherapy (IMRT) for early glottic cancer and to report preliminary clinical experience. Methods and Materials: Digital Imaging and Communications in Medicine radiotherapy (DICOM-RT) datasets from 6 T1-2 conventionally treated glottic cancer patients were used to create both conventional IMRT plans. We developed a simplified IMRT planning algorithm with three fields and limited segments. Conventional and IMRT plans were compared using generalized equivalent uniform dose and dose-volume parameters for in-field carotid arteries, target volumes, and organs at risk. We have treated 11 patients with this simplified IMRT technique. Results: Intensity-modulated radiotherapymore » consistently reduced radiation dose to the carotid arteries (p < 0.05) while maintaining the clinical target volume coverage. With conventional planning, median carotid V35, V50, and V63 were 100%, 100%, and 69.0%, respectively. With IMRT planning these decreased to 2%, 0%, and 0%, respectively (p < 0.01). Radiation planning and treatment times were similar for conventional radiotherapy and IMRT. Treatment results have been excellent thus far. Conclusions: Intensity-modulated radiotherapy significantly reduced unnecessary radiation dose to the carotid arteries compared with conventional lateral fields while maintaining clinical target volume coverage. Further experience and longer follow-up will be required to demonstrate outcomes for cancer control and carotid artery effects.« less

  10. Markerless gating for lung cancer radiotherapy based on machine learning techniques

    NASA Astrophysics Data System (ADS)

    Lin, Tong; Li, Ruijiang; Tang, Xiaoli; Dy, Jennifer G.; Jiang, Steve B.

    2009-03-01

    In lung cancer radiotherapy, radiation to a mobile target can be delivered by respiratory gating, for which we need to know whether the target is inside or outside a predefined gating window at any time point during the treatment. This can be achieved by tracking one or more fiducial markers implanted inside or near the target, either fluoroscopically or electromagnetically. However, the clinical implementation of marker tracking is limited for lung cancer radiotherapy mainly due to the risk of pneumothorax. Therefore, gating without implanted fiducial markers is a promising clinical direction. We have developed several template-matching methods for fluoroscopic marker-less gating. Recently, we have modeled the gating problem as a binary pattern classification problem, in which principal component analysis (PCA) and support vector machine (SVM) are combined to perform the classification task. Following the same framework, we investigated different combinations of dimensionality reduction techniques (PCA and four nonlinear manifold learning methods) and two machine learning classification methods (artificial neural networks—ANN and SVM). Performance was evaluated on ten fluoroscopic image sequences of nine lung cancer patients. We found that among all combinations of dimensionality reduction techniques and classification methods, PCA combined with either ANN or SVM achieved a better performance than the other nonlinear manifold learning methods. ANN when combined with PCA achieves a better performance than SVM in terms of classification accuracy and recall rate, although the target coverage is similar for the two classification methods. Furthermore, the running time for both ANN and SVM with PCA is within tolerance for real-time applications. Overall, ANN combined with PCA is a better candidate than other combinations we investigated in this work for real-time gated radiotherapy.

  11. Intraoperative and early postoperative complications of manual sutureless cataract extraction.

    PubMed

    Iqbal, Yasir; Zia, Sohail; Baig Mirza, Aneeq Ullah

    2014-04-01

    To determine the intraoperative and early postoperative complications of manual sutureless cataract extraction. Case series. Redo Eye Hospital, Rawalpindi, Pakistan, from January 2009 to December 2010. Three hundred patients of cataract through purposive non-probability sampling were selected. The patients underwent manual sutureless cataract surgery (MSCS) by single experienced surgeon and intraoperative complications were documented. The surgical technique was modified to deal with any intraoperative complications accordingly. Patients were examined on the first postoperative day and on the first postoperative week for any postoperative complications. The data was entered in Statistical Package for Social Sciences (SPSS) version 13.0 and the results were calculated in frequencies. Among the 300 cases, 81.3% surgeries went uneventful whereas 18.6% had some complication. The common intraoperative complications were superior button-hole formation in 5%; posterior capsular rent in 5% and premature entry with iris prolapse in 3% cases. Postoperatively, the commonly encountered complications were striate keratopathy in 9.6% and hyphema 9%. At first week follow-up, 4% had striate keratopathy and 0.6% had hyphema. Striate keratopathy resolved with topical medication on subsequent follow-up. A total of 9 cases (3%) underwent second surgery: 2 cases for lens matter wash, 2 cases for hyphema and 5 cases needed suturing of wound for shallow anterior chamber due to wound leak. Superior button-hole formation, posterior capsular rent and premature entry were the common intraoperative complications of MSCS whereas the common early postoperative complications were striate keratopathy and hyphema.

  12. Categorization of intraoperative ureteroscopy complications using modified Satava classification system.

    PubMed

    Tepeler, Abdulkadir; Resorlu, Berkan; Sahin, Tolga; Sarikaya, Selcuk; Bayindir, Mirze; Oguz, Ural; Armagan, Abdullah; Unsal, Ali

    2014-02-01

    To review our experience with ureteroscopy (URS) in the treatment of ureteral calculi and stratify intraoperative complications of URS according to the modified Satava classification system. We performed a retrospective analysis of 1,208 patients (672 males and 536 females), with a mean age of 43.1 years (range 1-78), who underwent ureteroscopic procedures for removal of ureteral stones. Intraoperative complications were recorded according to modified Satava classification system. Grade 1 complications included incidents without consequences for the patient; grade 2 complications, which are treated intraoperatively with endoscopic surgery (grade 2a) or required endoscopic re-treatment (grade 2b); and grade 3 complications included incidents requiring open or laparoscopic surgery. The stones were completely removed in 1,067 (88.3%) patients after primary procedure by either simple extraction or after fragmentation. The overall incidence of intraoperative complications was 12.6%. The most common complications were proximal stone migration (3.9%), mucosal injury (2.8%), bleeding (1.9%), inability to reach stone (1.8%), malfunctioning or breakage of instruments (0.8%), ureteral perforation (0.8%) and ureteral avulsion (0.16%). According to modified Satava classification system, there were 4.5% grade 1; 4.4% grade 2a; 3.2% grade 2b; and 0.57% grade 3 complications. We think that modified Satava classification is a quick and simple system for describing the severity of intraoperative URS complications and this grading system will facilitate a better comparison for the surgical outcomes obtained from different centers.

  13. Intraoperative Identification of the Parathyroid Gland with a Fluorescence Detection System.

    PubMed

    Shinden, Yoshiaki; Nakajo, Akihiro; Arima, Hideo; Tanoue, Kiyonori; Hirata, Munetsugu; Kijima, Yuko; Maemura, Kosei; Natsugoe, Shoji

    2017-06-01

    Intraoperative identification of the difficult-to-spot parathyroid gland is critical during surgery for thyroid and parathyroid disease. Recently, intrinsic fluorescence of the parathyroid gland was identified, and a new method was developed for intraoperative detection of the parathyroid with an original fluorescent detection apparatus. Here, we describe a method for intraoperative detection of the parathyroid using a ready-made photodynamic eye (PDE) system without any fluorescent dye or contrast agents. Seventeen patients who underwent surgical treatment for thyroid or parathyroid disease at Kagoshima University Hospital were enrolled in this study. Intrinsic fluorescence of various tissues was detected with the PDE system. Intraoperative in vivo and ex vivo intrinsic fluorescence of the parathyroid, thyroid, lymph nodes and fat tissues was measured and analyzed. The parathyroid gland had a significantly higher fluorescence intensity than the other tissues, including the thyroid glands, lymph nodes and fat tissues, and we could identify them during surgery using the fluorescence-guided method. Our method could be applicable for two intraoperative clinical procedures: ex vivo tissue identification of parathyroid tissue and in vivo identification of the location of the parathyroid gland, including ectopic glands. The PDE system may be an easy and highly feasible method to identify the parathyroid gland during surgery.

  14. Radiotherapy in Italy after conservative treatment of early breast cancer. A survey by the Italian Society of Radiation Oncology (AIRO).

    PubMed

    Aristei, Cynthia; Amichetti, Maurizio; Ciocca, Mario; Nardone, Luigia; Bertoni, Filippo; Vidali, Cristiana

    2008-01-01

    The aim of surveys on clinical practice is to stimulate discussion and optimize practice. In this paper the current Italian radiotherapy practice after breast-conserving surgery for early breast cancer is described and adherence to national and international guidelines is assessed. Furthermore, results are compared with an earlier survey in northern Italy and international reports. A multiple-choice questionnaire sent to all 138 Italian radiation oncology centers. 48% of centers responded. Most performed breast-conserving surgery when tumor size was < or =3 cm. All centers routinely performed axillary dissection; 45 carried out sentinel node biopsy followed by axillary dissection when the sentinel node was positive. Most centers re-excised when resection margins were positive. The median interval between surgery and radiotherapy, when chemotherapy was not administered, was 60 days. Adjuvant chemotherapy was preferably administered before radiotherapy. Regional lymph nodes were never irradiated in 10 centers; in all others irradiation depended on the number of positive lymph nodes and/or involvement of axillary fat and/or tumor location in medial quadrants. All centers used standard fractionation; hypofractionated schemes were available in 6. Most centers used 4-6 MV photons. In 59 centers the boost dose of 10 Gy could be increased if margins were not negative. All centers ensured patient setup reproducibility. Treatment planning was computerized in 59 centers. The irradiation dose was prescribed at the ICRU point in 56 centers and portal films were made in 54 centers. Intraoperative radiotherapy was used in 4 centers: for partial breast irradiation in 1 and for boost administration in 3 centers. Although the quality of radiotherapy delivery has improved in Italy in recent years, approaches that do not conform to international standards persist.

  15. Dosimetric and geometric evaluation of a hybrid strategy of offline adaptive planning and online image guidance for prostate cancer radiotherapy.

    PubMed

    Liu, Han; Wu, Qiuwen

    2011-08-07

    For prostate cancer patients, online image-guided (IG) radiotherapy has been widely used in clinic to correct the translational inter-fractional motion at each treatment fraction. For uncertainties that cannot be corrected online, such as rotation and deformation of the target volume, margins are still required to be added to the clinical target volume (CTV) for the treatment planning. Offline adaptive radiotherapy has been implemented to optimize the treatment for each individual patient based on the measurements at early stages of treatment process. It has been shown that offline adaptive radiotherapy can effectively reduce the required margin. Recently a hybrid strategy of offline adaptive replanning and online IG was proposed and the geometric evaluation was performed. It was found that the planning margins can further be reduced by 1-2 mm compared to online IG only strategy. The purpose of this study was to investigate the dosimetric benefits of such a hybrid strategy on the target and organs at risk. A total of 420 repeated helical computed tomography scans from 28 patients were included in the study. Both low-risk patients (LRP, CTV = prostate) and intermediate-risk patients (IRP, CTV = prostate + seminal vesicles, SV) were included in the simulation. Two registration methods, based on center-of-mass shift of prostate only and prostate plus SV, were performed for IRP. The intensity-modulated radiotherapy was used in the simulation. Criteria on both cumulative and fractional doses were evaluated. Furthermore, the geometric evaluation was extended to investigate the optimal number of fractions necessary to construct the internal target volume (ITV) for the hybrid strategy. The dosimetric margin improvement was smaller than its geometric counterpart and was in the range of 0-1 mm. The optimal number of fractions necessary for the ITV construction is 2 for LRPs and 3-4 for IRPs in a hypofractionation protocol. A new cumulative index of target volume was proposed

  16. Tumor location and IDH1 mutation may predict intraoperative seizures during awake craniotomy.

    PubMed

    Gonen, Tal; Grossman, Rachel; Sitt, Razi; Nossek, Erez; Yanaki, Raneen; Cagnano, Emanuela; Korn, Akiva; Hayat, Daniel; Ram, Zvi

    2014-11-01

    Intraoperative seizures during awake craniotomy may interfere with patients' ability to cooperate throughout the procedure, and it may affect their outcome. The authors have assessed the occurrence of intraoperative seizures during awake craniotomy in regard to tumor location and the isocitrate dehydrogenase 1 (IDH1) status of the tumor. Data were collected in 137 consecutive patients who underwent awake craniotomy for removal of a brain tumor. The authors performed a retrospective analysis of the incidence of seizures based on the tumor location and its IDH1 mutation status, and then compared the groups for clinical variables and surgical outcome parameters. Tumor location was strongly associated with the occurrence of intraoperative seizures. Eleven patients (73%) with tumor located in the supplementary motor area (SMA) experienced intraoperative seizures, compared with 17 (13.9%) with tumors in the other three non-SMA brain regions (p < 0.0001). Interestingly, there was no significant association between history of seizures and tumor location (p = 0.44). Most of the patients (63.6%) with tumor in the SMA region harbored an IDH1 mutation compared with those who had tumors in non-SMA regions. Thirty-one of 52 patients (60%) with a preoperative history of seizures had an IDH1 mutation (p = 0.02), and 15 of 22 patients (68.2%) who experienced intraoperative seizures had an IDH1 mutation (p = 0.03). In a multivariate analysis, tumor location was found as a significant predictor of intraoperative seizures (p = 0.002), and a trend toward IDH1 mutation as such a predictor was found as well (p = 0.06). Intraoperative seizures were not associated with worse outcome. Patients with tumors located in the SMA are more prone to develop intraoperative seizures during awake craniotomy compared with patients who have a tumor in non-SMA frontal areas and other brain regions. The IDH1 mutation was more common in SMA region tumors compared with other brain regions, and may be an

  17. Quo vadis radiotherapy? Technological advances and the rising problems in cancer management.

    PubMed

    Allen, Barry J; Bezak, Eva; Marcu, Loredana G

    2013-01-01

    Despite the latest technological advances in radiotherapy, cancer control is still challenging for several tumour sites. The survival rates for the most deadly cancers, such as ovarian and pancreatic, have not changed over the last decades. The solution to the problem lies in the change of focus: from local treatment to systemic therapy. The aim of this paper is to present the current status as well as the gaps in radiotherapy and, at the same time, to look into potential solutions to improve cancer control and survival. The currently available advanced radiotherapy treatment techniques have been analysed and their cost-effectiveness discussed. The problem of systemic disease management was specifically targeted. Clinical studies show limited benefit in cancer control from hadron therapy. However, targeted therapies together with molecular imaging could improve treatment outcome for several tumour sites while controlling the systemic disease. The advances in photon therapy continue to be competitive with the much more expensive hadron therapy. To justify the cost effectiveness of proton/heavy ion therapy, there is a need for phase III randomised clinical trials. Furthermore, the success of systemic disease management lies in the fusion between radiation oncology technology and microbiology.

  18. Economic analysis of an intraoperative cell salvage service.

    PubMed

    Szpisjak, Dale F; Potter, Paul S; Capehart, Bruce P

    2004-01-01

    In the United States, the cost of erythrocyte transfusion exceeds 1.3 billion dollars annually. The fear of viral disease transmission popularized intraoperative salvage to reduce the use of banked blood. Although the economics of this technique have been questioned, the financial variables in providing an intraoperative autotransfusion service have not been analyzed. We designed mathematical models to determine the most cost-effective strategy based on hospital caseload. Four models were analyzed with a spreadsheet to project costs of an intraoperative autotransfusion service when fully or partially outsourced, performed by a full-time technician employee, or performed by a cross-trained employee. The Partially Outsourced model was more economical than the Fully Outsourced model when the annual caseload exceeded 185 cases. The New Employee model became more economical than the Fully Outsourced model when the annual caseload exceeded 110 cases. The Cross-Trained model was the most economical when annual caseload exceeded 55 cases. Cross-training an employee as a cell salvage technician is more economical than outsourcing when caseload exceeds 55 per year.

  19. Overall survival and the response to radiotherapy among molecular subtypes of breast cancer brain metastases treated with targeted therapies.

    PubMed

    Miller, Jacob A; Kotecha, Rupesh; Ahluwalia, Manmeet S; Mohammadi, Alireza M; Chao, Samuel T; Barnett, Gene H; Murphy, Erin S; Vogelbaum, Michael A; Angelov, Lilyana; Peereboom, David M; Suh, John H

    2017-06-15

    The current study was conducted to investigate survival and the response to radiotherapy among patients with molecular subtypes of breast cancer brain metastases treated with or without targeted therapies. Patients diagnosed with breast cancer brain metastases at a single tertiary care institution were included. The primary outcome was overall survival, whereas secondary outcomes included the cumulative incidences of distant intracranial failure, local failure, and radiation necrosis. Competing risks regression was used to model secondary outcomes. Within the study period, 547 patients presented with 3224 brain metastases and met inclusion criteria. Among patients with human epidermal growth factor receptor 2 (HER2)-amplified disease, 80% received HER2 antibodies and 38% received HER2/epidermal growth factor receptor tyrosine kinase inhibitors (TKIs). The median survival was significantly shorter in the basal cohort (8.4 months), and progressively increased in the luminal A (12.3 months), HER2-positive (15.4 months), and luminal B (18.8 months) cohorts (P<.001). Among patients with HER2-amplified disease, the median survival was extended with the use of both HER2 antibodies (17.9 months vs 15.1 months; P = .04) and TKIs (21.1 months vs 15.4 months; P = .03). The 12-month cumulative incidences of local failure among molecular subtypes were 6.0% in the luminal A cohort, 10.3% in the luminal B cohort, 15.4% in the HER2-positive cohort, and 9.9% in the basal cohort (P = .01). Concurrent HER2/epidermal growth factor receptor TKIs with stereotactic radiosurgery significantly decreased the 12-month cumulative incidence of local failure from 15.1% to 5.7% (P<.001). Molecular subtypes appear to be prognostic for survival and predictive of the response to radiotherapy. TKIs were found to improve survival and local control, and may decrease the rate of distant failure. To preserve neurocognition, these results support a paradigm of upfront radiosurgery and HER2

  20. Intraoperative monitoring technician: a new member of the surgical team.

    PubMed

    Brown, Molly S; Brown, Debra S

    2011-02-01

    As surgery needs have increased, the traditional surgical team has expanded to include personnel from radiology and perfusion services. A new surgical team member, the intraoperative monitoring technician, is needed to perform intraoperative monitoring during procedures that carry a higher risk of central and peripheral nerve injury. Including the intraoperative monitoring technician on the surgical team can create challenges, including surgical delays and anesthesia care considerations. When the surgical team members, including the surgeon, anesthesia care provider, and circulating nurse, understand and facilitate this new staff member's responsibilities, the technician is able to perform monitoring functions that promote the smooth flow of the surgical procedure and positive patient outcomes. Copyright © 2011 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  1. Dosimetry for electron Intra-Operative RadioTherapy: Comparison of output factors obtained through alanine/EPR pellets, ionization chamber and Monte Carlo-GEANT4 simulations for IORT mobile dedicate accelerator

    NASA Astrophysics Data System (ADS)

    Marrale, Maurizio; Longo, Anna; Russo, Giorgio; Casarino, Carlo; Candiano, Giuliana; Gallo, Salvatore; Carlino, Antonio; Brai, Maria

    2015-09-01

    In this work a comparison between the response of alanine and Markus ionization chamber was carried out for measurements of the output factors (OF) of electron beams produced by a linear accelerator used for Intra-Operative Radiation Therapy (IORT). Output factors (OF) for conventional high-energy electron beams are normally measured using ionization chamber according to international dosimetry protocols. However, the electron beams used in IORT have characteristics of dose per pulse, energy spectrum and angular distribution quite different from beams usually used in external radiotherapy, so the direct application of international dosimetry protocols may introduce additional uncertainties in dosimetric determinations. The high dose per pulse could lead to an inaccuracy in dose measurements with ionization chamber, due to overestimation of ks recombination factor. Furthermore, the electron fields obtained with IORT-dedicated applicators have a wider energy spectrum and a wider angular distribution than the conventional fields, due to the presence of electrons scattered by the applicator's wall. For this reason, a dosimetry system should be characterized by a minimum dependence from the beam energy and from angle of incidence of electrons. This become particularly critical for small and bevelled applicators. All of these reasons lead to investigate the use of detectors different from the ionization chamber for measuring the OFs. Furthermore, the complete characterization of the radiation field could be accomplished also by the use of Monte Carlo simulations which allows to obtain detailed information on dose distributions. In this work we compare the output factors obtained by means of alanine dosimeters and Markus ionization chamber. The comparison is completed by the Monte Carlo calculations of OFs determined through the use of the Geant4 application "iort _ therapy" . The results are characterized by a good agreement of response of alanine pellets and Markus

  2. Intraoperative Assessment of Tricuspid Valve Function After Conservative Repair

    PubMed Central

    Revuelta, J.M.; Gomez-Duran, C.; Garcia-Rinaldi, R.; Gallagher, M.W.

    1982-01-01

    It is desirable to repair coexistent tricuspid valve pathology at the time of mitral valve corrections. Conservative tricuspid repair may consist of commissurotomy, annuloplasty, or both. It is important that the repair be appropriate or tricuspid valve replacement may be necessary. A simple reproducible method of intraoperative testing for tricuspid valve insufficiency has been developed and used in 25 patients. Fifteen patients have been recatheterized, and the correlation between the intraoperative and postoperative findings has been consistent. PMID:15226931

  3. The effect of ephedrine on intraoperative hypothermia

    PubMed Central

    Jo, Youn Yi; Kim, Ji Young; Kim, Joon-Sik; Kwon, Youngjun

    2011-01-01

    Background Prevention of intraoperative hypothermia has become a standard of operative care. Since ephedrine has a thermogenic effect and it is frequently used to treat hypotension during anesthesia, this study was designed to determine the effect of ephedrine on intraoperative hypothermia of patients who are undergoing spine surgery. Methods Twenty-four patients were randomly divided to receive an ephedrine (the ephedrine group, n = 12) or normal saline (the control group, n = 12) infusion for 2 h. The esophageal temperature (the core temperature), the index finger temperature (the peripheral temperature) and the hemodynamic variables such as the mean blood pressure and heart rate were measured every 15 minutes after the intubation. Results At the end of the study period, the esophageal temperature and hemodynamic variables were significantly decreased in the control group, whereas those in the ephedrine group were stably maintained. The index finger temperature was significantly lower in the ephedrine group compared to that in the control group, suggesting the prevention of core-to-peripheral redistribution of the heat as the cause of temperature maintenance. Conclusions An intraoperative infusion of ephedrine minimized the decrease of the core temperature and it stably maintained the hemodynamic variables during spine surgery with the patient under general anesthesia. PMID:21602974

  4. Intraoperative Raman spectroscopy of soft tissue sarcomas.

    PubMed

    Nguyen, John Q; Gowani, Zain S; O'Connor, Maggie; Pence, Isaac J; Nguyen, The-Quyen; Holt, Ginger E; Schwartz, Herbert S; Halpern, Jennifer L; Mahadevan-Jansen, Anita

    2016-10-01

    Soft tissue sarcomas (STS) are a rare and heterogeneous group of malignant tumors that are often treated through surgical resection. Current intraoperative margin assessment methods are limited and highlight the need for an improved approach with respect to time and specificity. Here we investigate the potential of near-infrared Raman spectroscopy for the intraoperative differentiation of STS from surrounding normal tissue. In vivo Raman measurements at 785 nm excitation were intraoperatively acquired from subjects undergoing STS resection using a probe based spectroscopy system. A multivariate classification algorithm was developed in order to automatically identify spectral features that can be used to differentiate STS from the surrounding normal muscle and fat. The classification algorithm was subsequently tested using leave-one-subject-out cross-validation. With the exclusion of well-differentiated liposarcomas, the algorithm was able to classify STS from the surrounding normal muscle and fat with a sensitivity and specificity of 89.5% and 96.4%, respectively. These results suggest that single point near-infrared Raman spectroscopy could be utilized as a rapid and non-destructive surgical guidance tool for identifying abnormal tissue margins in need of further excision. Lasers Surg. Med. 48:774-781, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  5. Postoperative neurological deficits may occur despite unchanged intraoperative somatosensory evoked potentials.

    PubMed

    Lesser, R P; Raudzens, P; Lüders, H; Nuwer, M R; Goldie, W D; Morris, H H; Dinner, D S; Klem, G; Hahn, J F; Shetter, A G

    1986-01-01

    We describe 6 patients who demonstrated postoperative neurological deficits despite unchanged somatosensory evoked potentials during intraoperative monitoring. Although there is both experimental and clinical evidence that somatosensory evoked potentials are sensitive to some types of intraoperative mishap, the technique should be employed with an awareness of its possible limitations.

  6. Risk of intraoperative hypotension with loop diuretics: a randomized controlled trial.

    PubMed

    Khan, Nadia A; Campbell, Norman R; Frost, Shaun D; Gilbert, Ken; Michota, Frank A; Usmani, Ali; Seal, Doug; Ghali, William A

    2010-11-01

    There is growing concern regarding the safety of blood pressure-lowering medications administered during the perioperative period. Whether loop diuretics also induce intraoperative hypotension is uncertain. Our objective was to compare the effects of continuing or withholding furosemide on the day of noncardiac elective surgery on intraoperative hypotension among chronic users of furosemide. A double blind, randomized, placebo controlled trial was conducted at 3 North American university centers between September 2000 and December 2006. Participants were randomly assigned in a 1:1 ratio to receive either furosemide or placebo on the day of surgery. The primary outcome was risk of developing intraoperative hypotension. A priori secondary outcomes included risk of heart failure; composite cardiovascular event (myocardial infarction, arrhythmia, stroke or transient ischemic attack, or death); and change in renal function and electrolytes. Of the 212 patients enrolled, 193 patients underwent surgery. There was no significant difference in risk of developing intraoperative hypotension between the furosemide (49%) and placebo (51.9%) groups (relative risk [RR], 0.95; 95% confidence interval [CI], 0.72-1.24; P = .78). The intraoperative administration of vasopressors and fluids were similar between both groups. The risk of developing postoperative cardiovascular events was not significantly different between those randomized to furosemide (4.8%) or placebo (2.8%) (RR, 1.73; 95% CI, 0.42-7.06; P = .49). There was no significant difference in renal function or electrolytes between the 2 groups. Among elective, noncardiac surgeries in patients chronically treated with furosemide, the administration of furosemide on the day of surgery did not significantly increase the risk for intraoperative hypotension. Copyright © 2010 Elsevier Inc. All rights reserved.

  7. Intraoperative Use of Low-Dose Recombinant Activated Factor VII During Thoracic Aortic Operations

    PubMed Central

    Andersen, Nicholas D.; Bhattacharya, Syamal D.; Williams, Judson B.; Fosbol, Emil L.; Lockhart, Evelyn L.; Patel, Mayur B.; Gaca, Jeffrey G.; Welsby, Ian J.; Hughes, G. Chad

    2013-01-01

    Background Numerous studies have supported the effectiveness of recombinant activated factor VII (rFVIIa) for the control of bleeding after cardiac procedures; however safety concerns persist. Here we report the novel use of intraoperative low-dose rFVIIa in thoracic aortic operations, a strategy intended to improve safety by minimizing rFVIIa exposure. Methods Between July 2005 and December 2010, 425 consecutive patients at a single referral center underwent thoracic aortic operations with cardiopulmonary bypass (CPB); 77 of these patients received intraoperative low-dose rFVIIa (≤60 μg/kg) for severe coagulopathy after CPB. Propensity matching produced a cohort of 88 patients (44 received intraoperative low-dose rFVIIa and 44 controls) for comparison. Results Matched patients receiving intraoperative low-dose rFVIIa got an initial median dose of 32 μg/kg (interquartile range [IQR], 16–43 μg/kg) rFVIIa given 51 minutes (42–67 minutes) after separation from CPB. Patients receiving intraoperative low-dose rFVIIa demonstrated improved postoperative coagulation measurements (partial thromboplastin time 28.6 versus 31.5 seconds; p = 0.05; international normalized ratio, 0.8 versus 1.2; p < 0.0001) and received 50% fewer postoperative blood product transfusions (2.5 versus 5.0 units; p = 0.05) compared with control patients. No patient receiving intraoperative low-dose rFVIIa required postoperative rFVIIa administration or reexploration for bleeding. Rates of stroke, thromboembolism, myocardial infarction, and other adverse events were equivalent between groups. Conclusions Intraoperative low-dose rFVIIa led to improved postoperative hemostasis with no apparent increase in adverse events. Intraoperative rFVIIa administration in appropriately selected patients may correct coagulopathy early in the course of refractory blood loss and lead to improved safety through the use of smaller rFVIIa doses. Appropriately powered randomized studies are necessary to confirm

  8. Intraoperative seizures and seizures outcome in patients underwent awake craniotomy.

    PubMed

    Yuan, Yang; Peizhi, Zhou; Xiang, Wang; Yanhui, Liu; Ruofei, Liang; Shu, Jiang; Qing, Mao

    2016-11-25

    Awake craniotomies (AC) could reduce neurological deficits compared with patients under general anesthesia, however, intraoperative seizure is a major reason causing awake surgery failure. The purpose of the study was to give a comprehensive overview the published articles focused on seizure incidence in awake craniotomy. Bibliographic searches of the EMBASE, MEDLINE,were performed to identify articles and conference abstracts that investigated the intraoperative seizure frequency of patients underwent AC. Twenty-five studies were included in this meta-analysis. Among the 25 included studies, one was randomized controlled trials and 5 of them were comparable studies. The pooled data suggested the general intraoperative seizure(IOS) rate for patients with AC was 8%(fixed effect model), sub-group analysis identified IOS rate for glioma patients was 8% and low grade patients was 10%. The pooled data showed early seizure rates of AC patients was 11% and late seizure rates was 35%. This systematic review and meta-analysis shows that awake craniotomy is a safe technique with relatively low intraoperative seizure occurrence. However, few RCTs were available, and the acquisition of further evidence through high-quality RCTs is highly recommended.

  9. Medical Error Avoidance in Intraoperative Neurophysiological Monitoring: The Communication Imperative.

    PubMed

    Skinner, Stan; Holdefer, Robert; McAuliffe, John J; Sala, Francesco

    2017-11-01

    Error avoidance in medicine follows similar rules that apply within the design and operation of other complex systems. The error-reduction concepts that best fit the conduct of testing during intraoperative neuromonitoring are forgiving design (reversibility of signal loss to avoid/prevent injury) and system redundancy (reduction of false reports by the multiplication of the error rate of tests independently assessing the same structure). However, error reduction in intraoperative neuromonitoring is complicated by the dichotomous roles (and biases) of the neurophysiologist (test recording and interpretation) and surgeon (intervention). This "interventional cascade" can be given as follows: test → interpretation → communication → intervention → outcome. Observational and controlled trials within operating rooms demonstrate that optimized communication, collaboration, and situational awareness result in fewer errors. Well-functioning operating room collaboration depends on familiarity and trust among colleagues. Checklists represent one method to initially enhance communication and avoid obvious errors. All intraoperative neuromonitoring supervisors should strive to use sufficient means to secure situational awareness and trusted communication/collaboration. Face-to-face audiovisual teleconnections may help repair deficiencies when a particular practice model disallows personal operating room availability. All supervising intraoperative neurophysiologists need to reject an insular or deferential or distant mindset.

  10. Intraoperative Imaging Guidance for Sentinel Node Biopsy in Melanoma Using a Mobile Gamma Camera

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dengel, Lynn T; Judy, Patricia G; Petroni, Gina R

    2011-04-01

    The objective is to evaluate the sensitivity and clinical utility of intraoperative mobile gamma camera (MGC) imaging in sentinel lymph node biopsy (SLNB) in melanoma. The false-negative rate for SLNB for melanoma is approximately 17%, for which failure to identify the sentinel lymph node (SLN) is a major cause. Intraoperative imaging may aid in detection of SLN near the primary site, in ambiguous locations, and after excision of each SLN. The present pilot study reports outcomes with a prototype MGC designed for rapid intraoperative image acquisition. We hypothesized that intraoperative use of the MGC would be feasible and that sensitivitymore » would be at least 90%. From April to September 2008, 20 patients underwent Tc99 sulfur colloid lymphoscintigraphy, and SLNB was performed with use of a conventional fixed gamma camera (FGC), and gamma probe followed by intraoperative MGC imaging. Sensitivity was calculated for each detection method. Intraoperative logistical challenges were scored. Cases in which MGC provided clinical benefit were recorded. Sensitivity for detecting SLN basins was 97% for the FGC and 90% for the MGC. A total of 46 SLN were identified: 32 (70%) were identified as distinct hot spots by preoperative FGC imaging, 31 (67%) by preoperative MGC imaging, and 43 (93%) by MGC imaging pre- or intraoperatively. The gamma probe identified 44 (96%) independent of MGC imaging. The MGC provided defined clinical benefit as an addition to standard practice in 5 (25%) of 20 patients. Mean score for MGC logistic feasibility was 2 on a scale of 1-9 (1 = best). Intraoperative MGC imaging provides additional information when standard techniques fail or are ambiguous. Sensitivity is 90% and can be increased. This pilot study has identified ways to improve the usefulness of an MGC for intraoperative imaging, which holds promise for reducing false negatives of SLNB for melanoma.« less

  11. A novel 3-dimensional electromagnetic guidance system increases intraoperative microwave antenna placement accuracy.

    PubMed

    Sastry, Amit V; Swet, Jacob H; Murphy, Keith J; Baker, Erin H; Vrochides, Dionisios; Martinie, John B; McKillop, Iain H; Iannitti, David A

    2017-12-01

    Failure to locate lesions and accurately place microwave antennas can lead to incomplete tumor ablation. The Emprint™ SX Ablation Platform employs real-time 3D-electromagnetic spatial antenna tracking to generate intraoperative laparoscopic antenna guidance. We sought to determine whether Emprint™ SX affected time/accuracy of antenna-placement in a laparoscopic training model. Targets (7-10 mm) were set in agar within a laparoscopic training device. Novices (no surgical experience), intermediates (surgical residents), and experts (HPB-surgeons) were asked to locate and hit targets using a MWA antenna (10-ultrasound only, 10-Emprint™ SX). Time to locate target, number of attempts to hit the target, first-time hit rate, and time from initiating antenna advance to hitting the target were measured. Participants located 100% of targets using ultrasound, with experts taking significantly less time than novices and intermediates. Using ultrasound only, successful hit-rates were 70% for novices and 90% for intermediates and experts. Using Emprint™ SX, successful hit rates for all 3-groups were 100%, with significantly increased first-time hit-rates and reduced time required to hit targets compared to ultrasound only. Emprint™ SX significantly improved accuracy and speed of antenna-placement independent of experience, and was particularly beneficial for novice users. Copyright © 2017 International Hepato-Pancreato-Biliary Association Inc. Published by Elsevier Ltd. All rights reserved.

  12. Analysis of Electronic Densities and Integrated Doses in Multiform Glioblastomas Stereotactic Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baron-Aznar, C.; Moreno-Jimenez, S.; Celis, M. A.

    2008-08-11

    Integrated dose is the total energy delivered in a radiotherapy target. This physical parameter could be a predictor for complications such as brain edema and radionecrosis after stereotactic radiotherapy treatments for brain tumors. Integrated Dose depends on the tissue density and volume. Using CT patients images from the National Institute of Neurology and Neurosurgery and BrainScan(c) software, this work presents the mean density of 21 multiform glioblastomas, comparative results for normal tissue and estimated integrated dose for each case. The relationship between integrated dose and the probability of complications is discussed.

  13. Analysis of Electronic Densities and Integrated Doses in Multiform Glioblastomas Stereotactic Radiotherapy

    NASA Astrophysics Data System (ADS)

    Barón-Aznar, C.; Moreno-Jiménez, S.; Celis, M. A.; Lárraga-Gutiérrez, J. M.; Ballesteros-Zebadúa, P.

    2008-08-01

    Integrated dose is the total energy delivered in a radiotherapy target. This physical parameter could be a predictor for complications such as brain edema and radionecrosis after stereotactic radiotherapy treatments for brain tumors. Integrated Dose depends on the tissue density and volume. Using CT patients images from the National Institute of Neurology and Neurosurgery and BrainScansoftware, this work presents the mean density of 21 multiform glioblastomas, comparative results for normal tissue and estimated integrated dose for each case. The relationship between integrated dose and the probability of complications is discussed.

  14. Three-dimensional intraoperative ultrasound of vascular malformations and supratentorial tumors.

    PubMed

    Woydt, Michael; Horowski, Anja; Krauss, Juergen; Krone, Andreas; Soerensen, Niels; Roosen, Klaus

    2002-01-01

    The benefits and limits of a magnetic sensor-based 3-dimensional (3D) intraoperative ultrasound technique during surgery of vascular malformations and supratentorial tumors were evaluated. Twenty patients with 11 vascular malformations and 9 supratentorial tumors undergoing microsurgical resection or clipping were investigated with an interactive magnetic sensor data acquisition system allowing freehand scanning. An ultrasound probe with a mounted sensor was used after craniotomies to localize lesions, outline tumors or malformation margins, and identify supplying vessels. A 3D data set was obtained allowing reformation of multiple slices in all 3 planes and comparison to 2-dimensional (2D) intraoperative ultrasound images. Off-line gray-scale segmentation analysis allowed differentiation between tissue with different echogenicities. Color-coded information about blood flow was extracted from the images with a reconstruction algorithm. This allowed photorealistic surface displays of perfused tissue, tumor, and surrounding vessels. Three-dimensional intraoperative ultrasound data acquisition was obtained within 5 minutes. Off-line analysis and reconstruction time depends on the type of imaging display and can take up to 30 minutes. The spatial relation between aneurysm sac and surrounding vessels or the skull base could be enhanced in 3 out of 6 aneurysms with 3D intraoperative ultrasound. Perforating arteries were visible in 3 cases only by using 3D imaging. 3D ultrasound provides a promising imaging technique, offering the neurosurgeon an intraoperative spatial orientation of the lesion and its vascular relationships. Thereby, it may improve safety of surgery and understanding of 2D ultrasound images.

  15. The Association Between Mild Intraoperative Hypotension and Stroke in General Surgery Patients.

    PubMed

    Hsieh, Jason K; Dalton, Jarrod E; Yang, Dongsheng; Farag, Ehab S; Sessler, Daniel I; Kurz, Andrea M

    2016-10-01

    Intraoperative hypotension may contribute to perioperative strokes. We therefore tested the hypothesis that intraoperative hypotension is associated with perioperative stroke. After institutional review board approval for this case-control study, we identified patients who had nonneurological, noncardiac, and noncarotid surgery under general anesthesia at the Cleveland Clinic between 2005 and 2011 and experienced a postoperative stroke. Control patients not experiencing postoperative stroke were matched in a 4-to-1 ratio using propensity scores and restriction to the same procedure type as stroke patients. The association between intraoperative hypotension, measured as time-integrated area under a mean arterial pressure (MAP) of 70 mm Hg, and postoperative stroke was assessed using zero-inflated negative binomial regression. Among 106 337 patients meeting inclusion criteria, we identified 120 who had confirmed postoperative stroke events based on manual chart review. Four-to-one propensity matching yielded a final matched sample of 104 stroke cases and 398 controls. There was no association between stroke and intraoperative hypotension. Stroke patients were not more likely than controls to have been hypotensive (odds ratio, 0.49 [0.18-1.38]), and among patients with intraoperative hypotension, stroke patients did not experience a greater degree of hypotension than controls (ratio of geometric means, 1.07 [0.76-1.53]). In our propensity score-matched case-control study, we did not find an association between intraoperative hypotension, defined as MAP < 70 mm Hg, and postoperative stroke.

  16. Preparing Platelet-Rich Plasma with Whole Blood Harvested Intraoperatively During Spinal Fusion.

    PubMed

    Shen, Bin; Zhang, Zheng; Zhou, Ning-Feng; Huang, Yu-Feng; Bao, Yu-Jie; Wu, De-Sheng; Zhang, Ya-Dong

    2017-07-22

    BACKGROUND Platelet-rich plasma (PRP) has gained growing popularity in use in spinal fusion procedures in the last decade. Substantial intraoperative blood loss is frequently accompanied with spinal fusion, and it is unknown whether blood harvested intraoperatively qualifies for PRP preparation. MATERIAL AND METHODS Whole blood was harvested intraoperatively and venous blood was collected by venipuncture. Then, we investigated the platelet concentrations in whole blood and PRP, the concentration of growth factors in PRP, and the effects of PRP on the proliferation and viability of human bone marrow-derived mesenchymal stem cells (HBMSCs). RESULTS Our results revealed that intraoperatively harvested whole blood and whole blood collected by venipuncture were similar in platelet concentration. In addition, PRP formulations prepared from both kinds of whole blood were similar in concentration of platelet and growth factors. Additional analysis showed that the similar concentrations of growth factors resulted from the similar platelet concentrations of whole blood and PRP between the two groups. Moreover, these two kinds of PRP formulations had similar effects on promoting cell proliferation and enhancing cell viability. CONCLUSIONS Therefore, intraoperatively harvested whole blood may be a potential option for preparing PRP spinal fusion.

  17. Intraoperative analysis of sentinel lymph nodes by imprint cytology for cancer of the breast.

    PubMed

    Shiver, Stephen A; Creager, Andrew J; Geisinger, Kim; Perrier, Nancy D; Shen, Perry; Levine, Edward A

    2002-11-01

    The utilization of lymphatic mapping techniques for breast carcinoma has made intraoperative evaluation of sentinel lymph nodes (SLN) attractive, because axillary lymph node dissection can be performed during the initial surgery if the SLN is positive. The optimal technique for rapid SLN assessment has not been determined. Both frozen sectioning and imprint cytology are used for rapid intraoperative SLN evaluation. A retrospective review of the intraoperative imprint cytology results of 133 SLN mapping procedures from 132 breast carcinoma patients was performed. SLN were evaluated intraoperatively by bisecting the lymph node and making imprints of each cut surface. Imprints were stained with hematoxylin and eosin (H&E) and Diff-Quik. Permanent sections were evaluated with up to four H&E stained levels and cytokeratin immunohistochemistry. Imprint cytology results were compared with final histologic results. Sensitivity and specificity of imprint cytology were 56% and 100%, respectively, producing a 100% positive predictive value and 88% negative predictive value. Imprint cytology was significantly more sensitive for macrometastasis than micrometastasis 87% versus 22% (P = 0.00007). Of 13 total false negatives, 11 were found to be due to sampling error and 2 due to errors in intraoperative interpretation. Both intraoperative interpretation errors involved a diagnosis of lobular breast carcinoma. The sensitivity and specificity of imprint cytology are similar to that of frozen section evaluation. Imprint cytology is therefore a viable alternative to frozen sectioning when intraoperative evaluation is required. If SLN micrometastasis is used to determine the need for further lymphadenectomy, more sensitive intraoperative methods will be needed to avoid a second operation.

  18. Targeted nanoparticles for tumour radiotherapy enhancement—the long dawn of a golden era?

    PubMed Central

    Gargioni, Elisabetta; Schulz, Florian; Raabe, Annette; Burdak-Rothkamm, Susanne; Rieckmann, Thorsten

    2016-01-01

    Despite considerable progress in (I) our understanding of the aetiopathology of head and neck cancer and (II) the precise delivery of radiotherapy, long-term survival rates for many patients with head and neck cancer remain disappointingly low. Over the past years, gold nanoparticles (NP) have emerged as promising radiation dose enhancers. In a recent study published in Nanoscale, Popovtzer et al. have used gold NP coated with an antibody against the epidermal growth factor receptor (EGFR) in an attempt to enhance radiation-induced tumour cell killing in a head and neck cancer xenograft model. They report a significant impact of the combined treatment with radiation and gold NP on tumour growth and suggest an involvement of apoptosis, inhibition of angiogenesis and diminished tissue repair. In this perspective, we illustrate the underlying radiobiophysical concepts and discuss some of the challenges associated with this and related nanoparticle-radiotherapy studies from a physics, chemistry, biology and therapy angle. We conclude that strong interdisciplinary collaborations spanning all these areas are crucially important to proceed towards effective cancer treatment with gold NP “from bench to bedside”. PMID:28151534

  19. Bladder radiotherapy treatment: A retrospective comparison of 3-dimensional conformal radiotherapy, intensity-modulated radiation therapy, and volumetric-modulated arc therapy plans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pasciuti, Katia, E-mail: k.pasciuti@virgilio.it; Kuthpady, Shrinivas; Anderson, Anne

    To examine tumor's and organ's response when different radiotherapy plan techniques are used. Ten patients with confirmed bladder tumors were first treated using 3-dimensional conformal radiotherapy (3DCRT) and subsequently the original plans were re-optimized using the intensity-modulated radiation treatment (IMRT) and volumetric-modulated arc therapy (VMAT)-techniques. Targets coverage in terms of conformity and homogeneity index, TCP, and organs' dose limits, including integral dose analysis were evaluated. In addition, MUs and treatment delivery times were compared. Better minimum target coverage (1.3%) was observed in VMAT plans when compared to 3DCRT and IMRT ones confirmed by a statistically significant conformity index (CI) results.more » Large differences were observed among techniques in integral dose results of the femoral heads. Even if no statistically significant differences were reported in rectum and tissue, a large amount of energy deposition was observed in 3DCRT plans. In any case, VMAT plans provided better organs and tissue sparing confirmed also by the normal tissue complication probability (NTCP) analysis as well as a better tumor control probability (TCP) result. Our analysis showed better overall results in planning using VMAT techniques. Furthermore, a total time reduction in treatment observed among techniques including gantry and collimator rotation could encourage using the more recent one, reducing target movements and patient discomfort.« less

  20. Temporary Intraoperative Porto-Caval Shunts in Piggy-Back Liver Transplantation Reduce Intraoperative Blood Loss and Improve Postoperative Transaminases and Renal Function: A Meta-Analysis.

    PubMed

    Pratschke, Sebastian; Rauch, Alexandra; Albertsmeier, Markus; Rentsch, Markus; Kirschneck, Michaela; Andrassy, Joachim; Thomas, Michael; Hartwig, Werner; Figueras, Joan; Del Rio Martin, Juan; De Ruvo, Nicola; Werner, Jens; Guba, Markus; Weniger, Maximilian; Angele, Martin K

    2016-12-01

    The value of temporary intraoperative porto-caval shunts (TPCS) in cava-sparing liver transplantation is discussed controversially. Aim of this meta-analysis was to analyze the impact of temporary intraoperative porto-caval shunts on liver injury, primary non-function, time of surgery, transfusion of blood products and length of hospital stay in cava-sparing liver transplantation. A systematic search of MEDLINE/PubMed, EMBASE and PsycINFO retrieved a total of 909 articles, of which six articles were included. The combined effect size and 95 % confidence interval were calculated for each outcome by applying the inverse variance weighting method. Tests for heterogeneity (I 2 ) were also utilized. Usage of a TPCS was associated with significantly decreased AST values, significantly fewer transfusions of packed red blood cells and improved postoperative renal function. There were no statistically significant differences in primary graft non-function, length of hospital stay or duration of surgery. This meta-analysis found that temporary intraoperative porto-caval shunts in cava-sparing liver transplantation reduce blood loss as well as hepatic injury and enhance postoperative renal function without prolonging operative time. Randomized controlled trials investigating the use of temporary intraoperative porto-caval shunts are needed to confirm these findings.

  1. Radiotherapy Improvements by Using Au Nanoparticles.

    PubMed

    Torrisi, Lorenzo

    2015-01-01

    Au nanoparticles can be prepared inside biological solutions and incorporated in special molecules for their transport through blood, drugs and proteins up to the tumour sites or directly injected in their volume when it is possible. The Au nanoparticles are biocompatible and can be accepted locally in the organism also at relatively high concentrations. The use of Au nanoparticles injected in the tumour site enhances significantly the effective atomic number of the medium, depending on the used concentration, and consequently the proton and electron energy loss and the X-ray absorption coefficient determining an increment of the local absorbed dose during radiotherapy. Traditional radiotherapy using electrons, X-rays and gamma rays, and innovative protontherapy can benefit the increment of the effective atomic number of the tissue in the presence of Au-nanoparticles embedded in the tumour volume with an adaptive up-take procedure. This method decreases the dose released to the healthy tissues permitting a better cantering of the irradiated targets and shielding the healthy tissue placed behind the tumour. The presented theoretical study approach permits to evaluate an enhancement of the radiotherapy dose of the order of 1 % using 60 MeV protons, of the order of 10% using 6 MeV electrons and of the order of 100 % using 100 keV X-ray photons. Here, we also disccused for patents relaed to the topic.

  2. Intraoperative assisting diagnosis of esophageal submucosal cancer using multiphoton microscopy

    NASA Astrophysics Data System (ADS)

    Zeng, Yaping; Xu, Jian; Zhou, Qun; Kang, Deyong; Zhuo, Shuangmu; Zhu, Xiaoqin; Lin, Jiangbo; Chen, Jianxin

    2018-07-01

    Multiphoton microscopy (MPM) based on two-photon excited fluorescence and second harmonic generation can achieve high-resolution images of biological tissues at the cellular and subcellular levels. In this work, we used MPM imaging of intraoperative hematoxylin and eosin (H&E)-stained frozen sections (FSs) of esophagus to explore whether MPM can provide complementary information to the auxiliary diagnosis of esophageal submucosal cancer during the intraoperative period. It was found that MPM has the ability not only to clearly reveal biological tissue microstructure and its morphological changes, but can reveal information not distinguishable in H&E-stained images. The complementary information of nonlinear spectral analysis, orientation and morphology changes in the collagen showed that MPM has important accessory diagnostic value for the differential diagnosis of submucosal carcinoma of the esophagus during the intraoperative period.

  3. Fluorescence Imaging Topography Scanning System for intraoperative multimodal imaging

    PubMed Central

    Quang, Tri T.; Kim, Hye-Yeong; Bao, Forrest Sheng; Papay, Francis A.; Edwards, W. Barry; Liu, Yang

    2017-01-01

    Fluorescence imaging is a powerful technique with diverse applications in intraoperative settings. Visualization of three dimensional (3D) structures and depth assessment of lesions, however, are oftentimes limited in planar fluorescence imaging systems. In this study, a novel Fluorescence Imaging Topography Scanning (FITS) system has been developed, which offers color reflectance imaging, fluorescence imaging and surface topography scanning capabilities. The system is compact and portable, and thus suitable for deployment in the operating room without disturbing the surgical flow. For system performance, parameters including near infrared fluorescence detection limit, contrast transfer functions and topography depth resolution were characterized. The developed system was tested in chicken tissues ex vivo with simulated tumors for intraoperative imaging. We subsequently conducted in vivo multimodal imaging of sentinel lymph nodes in mice using FITS and PET/CT. The PET/CT/optical multimodal images were co-registered and conveniently presented to users to guide surgeries. Our results show that the developed system can facilitate multimodal intraoperative imaging. PMID:28437441

  4. Intensity modulated radiotherapy and 3D conformal radiotherapy for whole breast irradiation: a comparative dosimetric study and introduction of a novel qualitative index for plan evaluation, the normal tissue index

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yim, Jackie; Suttie, Clare; Bromley, Regina

    We report on a retrospective dosimetric study, comparing 3D conformal radiotherapy (3DCRT) and hybrid intensity modulated radiotherapy (hIMRT). We evaluated plans based on their planning target volume coverage, dose homogeneity, dose to organs at risk (OARs) and exposure of normal tissue to radiation. The Homogeneity Index (HI) was used to assess the dose homogeneity in the target region, and we describe a new index, the normal tissue index (NTI), to assess the dose in the normal tissue inside the tangent treatment portal. Plans were generated for 25 early-stage breast cancer patients, using a hIMRT technique. These were compared with themore » 3DCRT plans of the treatment previously received by the patients. Plan quality was evaluated using the HI, NTI and dose to OARs. The hIMRT technique was significantly more homogenous than the 3DCRT technique, while maintaining target coverage. The hIMRT technique was also superior at minimising the amount of tissue receiving D{sub 105%} and above (P < 0.0001). The ipsilateral lung and contralateral breast maximum were significantly lower in the hIMRT plans (P < 0.05 and P < 0.005), but the 3DCRT technique achieved a lower mean heart dose in left-sided breast cancer patients (P < 0.05). Hybrid intensity modulated radiotherapy plans achieved improved dose homogeneity compared to the 3DCRT plans and superior outcome with regard to dose to normal tissues. We propose that the addition of both HI and NTI in evaluating the quality of intensity modulated radiotherapy (IMRT) breast plans provides clinically relevant comparators which more accurately reflect the new paradigm of treatment goals and outcomes in the era of breast IMRT.« less

  5. Intraoperative aberrometry-based aphakia refraction in patients with cataract: status and options.

    PubMed

    Huelle, Jan O; Druchkiv, Vasyl; Habib, Nabil E; Richard, Gisbert; Katz, Toam; Linke, Stephan J

    2017-02-01

    To explore the application of intraoperative wavefront aberrometry (IWA) for aphakia-based biometry using three existing formulae derived from autorefractive retinoscopy and introducing new improved formulae. In 74 patients undergoing cataract surgery, three repeated measurements of aphakic spherical equivalent (SE) were taken. All measurements were objectively graded for their quality and evaluated with the 'limits of agreement' approach. ORs were calculated and analysis of variance was applied. The intraocular lens (IOL) power that would have given the target refraction was back-calculated from manifest refraction at 3 months postoperatively. Regression analysis was performed to generate two aphakic SE-based formulae for predicting this IOL. The accuracy of the formulae was determined by comparing them to conventional biometry and published aphakia formulae. In 32 eyes, three consecutive aphakic measurements were successful. Objective parameters of IWA map quality significantly impacted measurement variability (p<0.05). The limits of agreement of repeated aphakic SE readings were +0.66 dioptre (D) and -0.69 D. Intraoperative biometry by our formula resulted in 25% and 53% of all cases ±0.50D and ±1.00 D within SE target, respectively. A second formula that took axial length (AL) into account resulted in improved ratios of 41% and 70%, respectively. A reliable application of IWA to calculate IOL power during routine cataract surgery may not be feasible given the high rate of measurement failures and the large variations of the readings. To enable reliable IOL calculation from IWA, measurement precision must be improved and aphakic IOL formulae need to be fine-tuned. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  6. Three-dimensional intrafractional internal target motions in accelerated partial breast irradiation using three-dimensional conformal external beam radiotherapy.

    PubMed

    Hirata, Kimiko; Yoshimura, Michio; Mukumoto, Nobutaka; Nakamura, Mitsuhiro; Inoue, Minoru; Sasaki, Makoto; Fujimoto, Takahiro; Yano, Shinsuke; Nakata, Manabu; Mizowaki, Takashi; Hiraoka, Masahiro

    2017-07-01

    We evaluated three-dimensional intrafractional target motion, divided into respiratory-induced motion and baseline drift, in accelerated partial breast irradiation (APBI). Paired fluoroscopic images were acquired simultaneously using orthogonal kV X-ray imaging systems at pre- and post-treatment for 23 patients who underwent APBI with external beam radiotherapy. The internal target motion was calculated from the surgical clips placed around the tumour cavity. The peak-to-peak respiratory-induced motions ranged from 0.6 to 1.5mm in all directions. A systematic baseline drift of 1.5mm towards the posterior direction and a random baseline drift of 0.3mm in the lateral-medial and cranial-caudal directions were observed. The baseline for an outer tumour cavity drifted towards the lateral and posterior directions, and that for an upper tumour cavity drifted towards the cranial direction. Moderate correlations were observed between the posterior baseline drift and the patients' physical characteristics. The posterior margin for intrafractional uncertainties was larger than 5mm in patients with greater fat thickness due to the baseline drift. The magnitude of the intrafractional motion was not uniform according to the direction, patients' physical characteristics, or tumour cavity location due to the baseline drift. Therefore, the intrafractional systematic movement should be properly managed. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Left-sided breast cancer irradiation using rotational and fixed-field radiotherapy.

    PubMed

    Qi, X Sharon; Liu, Tian X; Liu, Arthur K; Newman, Francis; Rabinovitch, Rachel; Kavanagh, Brian; Hu, Y Angie

    2014-01-01

    The 3-dimensional conformal radiotherapy (3DCRT) technique is the standard for breast cancer radiotherapy. During treatment planning, not only the coverage of the planning target volume (PTV) but also the minimization of the dose to critical structures, such as the lung, heart, and contralateral breast tissue, need to be considered. Because of the complexity and variations of patient anatomy, more advanced radiotherapy techniques are sometimes desired to better meet the planning goals. In this study, we evaluated external-beam radiation treatment techniques for left breast cancer using various delivery platforms: fixed-field including TomoDirect (TD), static intensity-modulated radiotherapy (sIMRT), and rotational radiotherapy including Elekta volumetric-modulated arc therapy (VMAT) and tomotherapy helical (TH). A total of 10 patients with left-sided breast cancer who did or did not have positive lymph nodes and were previously treated with 3DCRT/sIMRT to the entire breast were selected, their treatment was planned with Monaco VMAT, TD, and TH. Dosimetric parameters including PTV coverage, organ-at-risk (OAR) sparing, dose-volume histograms, and target minimum/maximum/mean doses were evaluated. It is found that for plans providing comparable PTV coverage, the Elekta VMAT plans were generally more inhomogeneous than the TH and TD plans. For the cases with regional node involvement, the average mean doses administered to the heart were 9.2 (± 5.2) and 8.8 (± 3.0)Gy in the VMAT and TH plans compared with 11.9 (± 6.4) and 11.8 (± 9.2)Gy for the 3DCRT and TD plans, respectively, with slightly higher doses given to the contralateral lung or breast or both. On average, the total monitor units for VMAT plans are 11.6% of those TH plans. Our studies have shown that VMAT and TH plans offer certain dosimetric advantages over fixed-field IMRT plans for advanced breast cancer requiring regional nodal treatment. However, for early-stage breast cancer fixed-field radiotherapy

  8. Intraoperative Seizures: Anesthetic and Antiepileptic Drugs.

    PubMed

    Uribe, Alberto; Zuleta-Alarcon, Alix; Kassem, Mahmoud; Sandhu, Gurneet S; Bergese, Sergio D

    2017-01-01

    Epilepsy is a common condition with up to 1% prevalence in the general population. In the perioperative course of neurologic surgery patients, the use of prophylactic and therapeutic antiepileptic drugs is a common practice. Nonetheless, there is limited evidence supporting the use of prophylactic antiepileptics to prevent perioperative seizures and there are no guidelines for which anesthetic technique is preferred. To discuss the seizurogenic potential of anesthetic drugs and to discuss intraoperative seizures in neurosurgical patients. We performed a search of the literature available in PubMed and Ovid MEDLINE. We also included articles identified in the review of the references of these articles. The incidence of seizures is heterogenic among neurosurgical patients. Seizure prophylaxis is widely administered despite limited available evidence of its effectiveness. In epileptic patients, the recommendation is to continue antiepileptic drugs in the perioperative setting. In these patients, anesthesiologists may also limit the use of medications that alter the seizure threshold and avoid medications that pose significant pharmacological interaction with antiepileptic drugs. In conclusion, a knowledgeable multidisciplinary perioperative team is essential to avoid, identify and treat intraoperative seizures competently. In patients with a history of epilepsy it is recommended to continue antiepileptic therapy. Therefore, clinical judgment should guide the decision of administering seizure prophylaxis in neurosurgery patients according to an individual assessment of potential risk for seizures. Furthermore, there is a need for randomized controlled trials that support new protocols and/or guidelines for anesthetic and perioperative regimens to prevent and treat intraoperative seizures. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  9. Intraoperative Oxygen Consumption During Liver Transplantation.

    PubMed

    Shibata, M; Matsusaki, T; Kaku, R; Umeda, Y; Yagi, T; Morimatsu, H

    2015-12-01

    The aim of this study was to investigate the changes in oxygen consumption during liver transplantation and to examine the relationship between intraoperatively elevated systemic oxygen consumption and postoperative liver function. This study was performed in 33 adult patients undergoing liver transplantation between September 2011 and March 2014. We measured intraoperative oxygen consumption through the use of indirect calorimetry, preoperative and intraoperative data, liver function tests, and postoperative complications and outcomes. The mean age of patients was 52 ± 9.7 years; 14 (42%) of them were women. Average Model for End-Stage Liver Disease scores were 20 ± 8.9. Oxygen consumption significantly increased after reperfusion from 172 ± 30 mL/min during the anhepatic phase to 209 ± 30 mL/min (P < .0001). We divided patients into 2 groups according to the increase in oxygen consumption after reperfusion (oxygen consumption after reperfusion minus anhepatic phase oxygen consumption: 40 mL/min increase as cutoff). The higher consumption group had a longer cold ischemia time and higher postoperative aspartate aminotransferase and alanine aminotransferase levels as compared with the lower oxygen consumption group. There were no statistically significant differences in major postoperative complications, but the higher oxygen consumption group tended to have shorter hospital stays than the lower consumption group (58 versus 95 days). We have demonstrated that oxygen consumption significantly increased after reperfusion. Furthermore, this increased oxygen consumption was associated with a longer cold ischemia time and shorter hospital stays. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. A Dosimetric Comparison of Breast Radiotherapy Techniques to Treat Locoregional Lymph Nodes Including the Internal Mammary Chain.

    PubMed

    Ranger, A; Dunlop, A; Hutchinson, K; Convery, H; Maclennan, M K; Chantler, H; Twyman, N; Rose, C; McQuaid, D; Amos, R A; Griffin, C; deSouza, N M; Donovan, E; Harris, E; Coles, C E; Kirby, A

    2018-06-01

    Radiotherapy target volumes in early breast cancer treatment increasingly include the internal mammary chain (IMC). In order to maximise survival benefits of IMC radiotherapy, doses to the heart and lung should be minimised. This dosimetry study compared the ability of three-dimensional conformal radiotherapy, arc therapy and proton beam therapy (PBT) techniques with and without breath-hold to achieve target volume constraints while minimising dose to organs at risk (OARs). In 14 patients' datasets, seven IMC radiotherapy techniques were compared: wide tangent (WT) three-dimensional conformal radiotherapy, volumetric-modulated arc therapy (VMAT) and PBT, each in voluntary deep inspiratory breath-hold (vDIBH) and free breathing (FB), and tomotherapy in FB only. Target volume coverage and OAR doses were measured for each technique. These were compared using a one-way ANOVA with all pairwise comparisons tested using Bonferroni's multiple comparisons test, with adjusted P-values ≤ 0.05 indicating statistical significance. One hundred per cent of WT(vDIBH), 43% of WT(FB), 100% of VMAT(vDIBH), 86% of VMAT(FB), 100% of tomotherapy FB and 100% of PBT plans in vDIBH and FB passed all mandatory constraints. However, coverage of the IMC with 90% of the prescribed dose was significantly better than all other techniques using VMAT(vDIBH), PBT(vDIBH) and PBT(FB) (mean IMC coverage ± 1 standard deviation = 96.0% ± 4.3, 99.8% ± 0.3 and 99.0% ± 0.2, respectively). The mean heart dose was significantly reduced in vDIBH compared with FB for both the WT (P < 0.0001) and VMAT (P < 0.0001) techniques. There was no advantage in target volume coverage or OAR doses for PBT(vDIBH) compared with PBT(FB). Simple WT radiotherapy delivered in vDIBH achieves satisfactory coverage of the IMC while meeting heart and lung dose constraints. However, where higher isodose coverage is required, VMAT(vDIBH) is the optimal photon technique. The lowest OAR doses are achieved by PBT

  11. Intraoperative Recurrent Laryngeal Nerve Monitoring in a Patient with Contralateral Vocal Fold Palsy.

    PubMed

    Na, Bub-Se; Choi, Jin-Ho; Park, In Kyu; Kim, Young Tae; Kang, Chang Hyun

    2017-10-01

    Recurrent laryngeal nerve injury can develop following cervical or thoracic surgery; however, few reports have described intraoperative recurrent laryngeal nerve monitoring. Consensus regarding the use of this technique during thoracic surgery is lacking. We used intraoperative recurrent laryngeal nerve monitoring in a patient with contralateral vocal cord paralysis who was scheduled for completion pneumonectomy. This case serves as an example of intraoperative recurrent laryngeal nerve monitoring during thoracic surgery and supports this indication for its use.

  12. Intraoperative acceleration measurements to quantify improvement in tremor during deep brain stimulation surgery.

    PubMed

    Shah, Ashesh; Coste, Jérôme; Lemaire, Jean-Jacques; Taub, Ethan; Schüpbach, W M Michael; Pollo, Claudio; Schkommodau, Erik; Guzman, Raphael; Hemm-Ode, Simone

    2017-05-01

    Deep brain stimulation (DBS) surgery is extensively used in the treatment of movement disorders. Nevertheless, methods to evaluate the clinical response during intraoperative stimulation tests to identify the optimal position for the implantation of the chronic DBS lead remain subjective. In this paper, we describe a new, versatile method for quantitative intraoperative evaluation of improvement in tremor with an acceleration sensor that is mounted on the patient's wrist during surgery. At each anatomical test position, the improvement in tremor compared to the initial tremor is estimated on the basis of extracted outcome measures. This method was tested on 15 tremor patients undergoing DBS surgery in two centers. Data from 359 stimulation tests were acquired. Our results suggest that accelerometric evaluation detects tremor changes more sensitively than subjective visual ratings. The effective stimulation current amplitudes identified from the quantitative data (1.1 ± 0.8 mA) are lower than those identified by visual evaluation (1.7 ± 0.8 mA) for similar improvement in tremor. Additionally, if these data had been used to choose the chronic implant position of the DBS lead, 15 of the 26 choices would have been different. These results show that our method of accelerometric evaluation can potentially improve DBS targeting.

  13. Doses to organs and tissues from concomitant imaging in radiotherapy: a suggested framework for clinical justification.

    PubMed

    Harrison, R M

    2008-12-01

    The increasing use of imaging for localization and verification in radiotherapy has raised issues concerning the justifiable doses to critical organs and tissues from concomitant exposures, particularly when extensive image-guided radiotherapy is indicated. Doses at positions remote from the target volume include components from high-energy leakage and scatter, as well as from concomitant imaging. In this paper, simulated prostate, breast and larynx treatments are used to compare doses from both high-energy and concomitant exposures as a function of distance from the target volume. It is suggested that the fraction, R, of the total dose at any point within the patient that is attributable to concomitant exposures may be a useful aid in their justification. R is small within the target volume and at large distances from it. However, there is a critical region immediately adjacent to the planning target volume where the dose from concomitant imaging combines with leakage and scatter to give values of R that approach 0.5 in the examples given here. This is noteworthy because the regions just outside the target volume will receive total doses in the order of 1 Gy, where commensurately high risk factors may not be substantially reduced because of cell kill. Other studies have identified these regions as sites of second cancers. The justification of an imaging regimen might therefore usefully take into account the maximum value of R encountered from the combination of imaging and radiotherapy for particular treatment sites.

  14. Intraoperative seizures during craniotomy under general anesthesia.

    PubMed

    Howe, John; Lu, Xiaoying; Thompson, Zoe; Peterson, Gordon W; Losey, Travis E

    2016-05-01

    An acute symptomatic seizure is a clinical seizure occurring at the time of or in close temporal association with a brain insult. We report an acute symptomatic seizure occurring during a surgical procedure in a patient who did not have a prior history of epilepsy and who did not have a lesion associated with an increased risk of epilepsy. To characterize the incidence and clinical features of intraoperative seizures during craniotomy under general anesthesia, we reviewed cases where continuous EEG was acquired during craniotomy. Records of 400 consecutive cases with propofol as general anesthesia during craniotomy were reviewed. Demographic data, indication for surgery, clinical history, history of prior seizures, duration of surgery and duration of burst suppression were recorded. Cases where seizures were observed were analyzed in detail. Two out of 400 patients experienced intraoperative seizures, including one patient who appeared to have an acute symptomatic seizure related to the surgical procedure itself and a second patient who experienced two seizures likely related to an underlying diagnosis of epilepsy. This is the first report of an acute symptomatic seizure secondary to a neurosurgical procedure. Overall, 0.5% of patients monitored experienced seizures, indicating that intraoperative seizures are rare, and EEG monitoring during craniotomies is of low yield in detecting seizures. Copyright © 2016. Published by Elsevier Ltd.

  15. Cisplatin-tethered gold nanospheres for multimodal chemo-radiotherapy of glioblastoma

    NASA Astrophysics Data System (ADS)

    Setua, Sonali; Ouberai, Myriam; Piccirillo, Sara G.; Watts, Colin; Welland, Mark

    2014-08-01

    Glioblastoma multiforme (GBM) remains the most aggressive and challenging brain tumour to treat. We report the first successful chemo-radiotherapy on patient derived treatment resistant GBM cells using a cisplatin-tethered gold nanosphere. After intracellular uptake, the nanosphere effects DNA damage which initiates caspase-mediated apoptosis in those cells. In the presence of radiation, both gold and platinum of cisplatin, serve as high atomic number radiosensitizers leading to the emission of ionizing photoelectrons and Auger electrons. This resulted in enhanced synergy between cisplatin and radiotherapy mediated cytotoxicity, and photo/Auger electron mediated radiosensitisation leading to complete ablation of the tumour cells in an in vitro model system. This study demonstrates the potential of designed nanoparticles to target aggressive cancers in the patient derived cell lines providing a platform to move towards treatment strategies.Glioblastoma multiforme (GBM) remains the most aggressive and challenging brain tumour to treat. We report the first successful chemo-radiotherapy on patient derived treatment resistant GBM cells using a cisplatin-tethered gold nanosphere. After intracellular uptake, the nanosphere effects DNA damage which initiates caspase-mediated apoptosis in those cells. In the presence of radiation, both gold and platinum of cisplatin, serve as high atomic number radiosensitizers leading to the emission of ionizing photoelectrons and Auger electrons. This resulted in enhanced synergy between cisplatin and radiotherapy mediated cytotoxicity, and photo/Auger electron mediated radiosensitisation leading to complete ablation of the tumour cells in an in vitro model system. This study demonstrates the potential of designed nanoparticles to target aggressive cancers in the patient derived cell lines providing a platform to move towards treatment strategies. Electronic supplementary information (ESI) available: Additional figures. See DOI: 10.1039/c

  16. Outcome of renal transplantation with and without intra-operative diuretics.

    PubMed

    Hanif, F; Macrae, A N; Littlejohn, M G; Clancy, M J; Murio, E

    2011-01-01

    This paper presents an e-survey of current clinical practice of use of intra-operative diuretics during renal transplantation in the United Kingdom and a study to compare outcome of renal transplants carried out with or without intra-operative diuretics in our centre. An e-mail questionnaire to renal transplant surgeons exploring their practice of renal transplantation with or without intra-operative diuretics, the type of a diuretic/s if used and the relevant doses. An observational study comparing the outcome of renal transplant recipients, group no-diuretics (GND, n = 80) carried out from 2004 to 2008 versus group diuretics (GD n = 69) renal transplant recipients who received intra-operative diuretics over a one year period is presented. Outcome measures were incidence of delayed graft function and a comparison of graft survival in both groups. Forty surgeons answered from 18 transplant centres with a response rate of 67%. 13 surgeons do not use diuretics. Mannitol is used by 10/40, Furosemide 6/40 and 11 surgeons use a combination of both. In comparative study there was no significant overall difference in one year graft survival of GD versus GND (N = 65/69, 94% and 75/80, 94% respectively, p = 0.08) and the incidence of delayed graft function was also comparable (16/69, 23% and 21/80, 26% respectively, p = 0.07). The donor characteristics in both groups were comparable. The study showed variation in clinical practice on the use of intra-operative diuretics in renal transplantation and it did not demonstrate that the use of diuretics can improve renal graft survival. Copyright © 2011 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  17. Intra-operative measurement of applied forces during anterior scoliosis correction.

    PubMed

    Fairhurst, H; Little, J P; Adam, C J

    2016-12-01

    Spinal instrumentation and fusion for the treatment of scoliosis is primarily a mechanical intervention to correct the deformity and halt further progression. While implant-related complications remain a concern, little is known about the magnitudes of the forces applied to the spine during surgery, which may affect post-surgical outcomes. In this study, the compressive forces applied to each spinal segment during anterior instrumentation were measured in a series of patients with Adolescent Idiopathic Scoliosis. A force transducer was designed and retrofit to a routinely used surgical tool, and compressive forces applied to each segment during surgery were measured for 15 scoliosis patients. Cobb angle correction achieved by each force was measured on intra-operative fluoroscope images. Relative changes in orientation of the screw within the vertebra were also measured to detect intra-operative screw plough. Intra-operative forces were measured for a total of 95 spinal segments. The mean applied compressive force was 540N (SD 230N, range 88N-1019N). There was a clear trend for higher forces to be applied at segments toward the apex of the scoliosis. Fluoroscopic evidence of screw plough was detected at 10 segments (10.5%). The magnitude of forces applied during anterior scoliosis correction vary over a broad range. These forces do reach magnitudes capable of causing intra-operative vertebral body screw plough. Surgeons should be aware there is a risk for tissue overload during correction, however the clinical implications of intra-operative screw plough remain unclear. The dataset presented here is valuable for providing realistic input parameters for in silico surgical simulations. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Intraoperative magnetic resonance imaging assessment of non-functioning pituitary adenomas during transsphenoidal surgery.

    PubMed

    Patel, Kunal S; Yao, Yong; Wang, Renzhi; Carter, Bob S; Chen, Clark C

    2016-04-01

    To review the utility of intraoperative imaging in facilitating maximal resection of non-functioning pituitary adenomas (NFAs). We performed an exhaustive MEDLINE search, which yielded 5598 articles. Upon careful review of these studies, 31 were pertinent to the issue of interest. Nine studies examined whether intraoperative MRI (iMRI) findings correlated with the presence of residual tumor on MRI taken 3 months after surgical resection. All studies using iMRI of >0.15T showed a ≥90% concordance between iMRI and 3-month post-operative MRI findings. 24 studies (22 iMRI and 2 intraoperative CT) examined whether intraoperative imaging improved the surgeon's ability to achieve a more complete resection. The resections were carried out under microscopic magnification in 17 studies and under endoscopic visualization in 7 studies. All studies support the value of intraoperative imaging in this regard, with improved resection in 15-83% of patients. Two studies examined whether iMRI (≥0.3T) improved visualization of residual NFA when compared to endoscopic visualization. Both studies demonstrated the value of iMRI in this regard, particularly when the tumor is located lateral of the sella, in the cavernous sinus, and in the suprasellar space. The currently available literature supports the utility of intraoperative imaging in facilitating increased NFA resection, without compromising safety.

  19. Capturing intraoperative deformations: research experience at Brigham and Women's Hospital.

    PubMed

    Warfield, Simon K; Haker, Steven J; Talos, Ion-Florin; Kemper, Corey A; Weisenfeld, Neil; Mewes, Andrea U J; Goldberg-Zimring, Daniel; Zou, Kelly H; Westin, Carl-Fredrik; Wells, William M; Tempany, Clare M C; Golby, Alexandra; Black, Peter M; Jolesz, Ferenc A; Kikinis, Ron

    2005-04-01

    During neurosurgical procedures the objective of the neurosurgeon is to achieve the resection of as much diseased tissue as possible while achieving the preservation of healthy brain tissue. The restricted capacity of the conventional operating room to enable the surgeon to visualize critical healthy brain structures and tumor margin has lead, over the past decade, to the development of sophisticated intraoperative imaging techniques to enhance visualization. However, both rigid motion due to patient placement and nonrigid deformations occurring as a consequence of the surgical intervention disrupt the correspondence between preoperative data used to plan surgery and the intraoperative configuration of the patient's brain. Similar challenges are faced in other interventional therapies, such as in cryoablation of the liver, or biopsy of the prostate. We have developed algorithms to model the motion of key anatomical structures and system implementations that enable us to estimate the deformation of the critical anatomy from sequences of volumetric images and to prepare updated fused visualizations of preoperative and intraoperative images at a rate compatible with surgical decision making. This paper reviews the experience at Brigham and Women's Hospital through the process of developing and applying novel algorithms for capturing intraoperative deformations in support of image guided therapy.

  20. Trend in and Correlates of Undergoing Radiotherapy in Taiwanese Cancer Patients' Last Month of Life.

    PubMed

    Hung, Yen-Ni; Cheng, Skye Hung-Chun; Liu, Tsang-Wu; Chang, Wen-Cheng; Chen, Jen-Shi; Tang, Siew Tzuh

    2016-09-01

    A significant proportion of cancer patients at end of life (EOL) undergo radiotherapy, but this evidence is not from nationwide population-based studies. The aims of this population-based study were to investigate the trend in undergoing radiotherapy among Taiwanese cancer patients' last month of life (EOL radiotherapy) in 2001-2010 and to identify factors associated with EOL radiotherapy. This was a population-based retrospective cohort study analyzing data from Taiwan's national death registry, cancer registry, and National Health Insurance claims for EOL radiotherapy using multilevel generalized linear mixed modeling. Participants were Taiwanese cancer patients (N = 339,546) who died in 2001-2010. Overall, 8.59% (7.97%-9.85%) of patients underwent EOL radiotherapy with a decreasing trend over time. Correlates of EOL radiotherapy included male gender, younger age, residing in less urbanized areas, diagnosis of lung cancer, metastatic disease, death within two years of diagnosis, and without comorbidities. Cancer patients were more likely to undergo EOL radiotherapy if they received primary care from medical oncologists and pediatricians, in a nonprofit, teaching hospital with a larger case volume of terminally ill cancer patients, and greater EOL care intensity. Approximately one-tenth of Taiwanese cancer patients underwent EOL radiotherapy with a decreasing trend over time. Undergoing EOL radiotherapy was associated with demographics, disease characteristics, physician specialty, and primary hospital's characteristics and EOL care practice patterns. Clinical and financial interventions should target hospitals/physicians that tend to aggressively treat at-risk cancer patients at EOL to carefully evaluate the appropriateness and effectiveness of using EOL radiotherapy. Copyright © 2016 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.

  1. Prevention of intraoperative cerebrospinal fluid leaks by lumbar cerebrospinal fluid drainage during surgery for pituitary macroadenomas.

    PubMed

    Mehta, Gautam U; Oldfield, Edward H

    2012-06-01

    Cerebrospinal fluid leakage is a major complication of transsphenoidal surgery. An intraoperative CSF leak, which occurs in up to 50% of pituitary tumor cases, is the only modifiable risk factor for postoperative leaks. Although several techniques have been described for surgical repair when an intraoperative leak is noted, none has been proposed to prevent an intraoperative CSF leak. The authors postulated that intraoperative CSF drainage would diminish tension on the arachnoid, decrease the rate of intraoperative CSF leakage during surgery for larger tumors, and reduce the need for surgical repair of CSF leaks. The results of 114 transsphenoidal operations for pituitary macroadenoma performed without intraoperative CSF drainage were compared with the findings from 44 cases in which a lumbar subarachnoid catheter was placed before surgery to drain CSF at the time of dural exposure and tumor removal. Cerebrospinal fluid drainage reduced the rate of intraoperative CSF leakage from 41% to 5% (p < 0.001). This reduction occurred in macroadenomas with (from 57% to 5%, p < 0.001) and those without suprasellar extension (from 29% to 0%, p = 0.31). The rate of postoperative CSF leakage was similar (5% vs 5%), despite the fact that intraoperative CSF drainage reduced the need for operative repair (from 32% to 5%, p < 0.001). There were no significant catheter-related complications. Cerebrospinal fluid drainage during transsphenoidal surgery for macroadenomas reduces the rate of intraoperative CSF leaks. This preventative measure obviated the need for surgical repair of intraoperative CSF leaks using autologous fat graft placement, other operative techniques, postoperative lumbar drainage, and/or reoperation in most patients and is associated with minimal risks.

  2. Behavioral Modification of Intraoperative Hyperglycemia Management with a Novel Real-time Audiovisual Monitor.

    PubMed

    Sathishkumar, Subramanian; Lai, Manda; Picton, Paul; Kheterpal, Sachin; Morris, Michelle; Shanks, Amy; Ramachandran, Satya Krishna

    2015-07-01

    Hyperglycemia, defined as blood glucose (BG) levels above 200 mg/dl (11.1 mM), is associated with increased postoperative morbidity. Yet, the treatment standard for intraoperative glycemic control is poorly defined for noncardiac surgery. Little is known of the interindividual treatment variability or methods to modify intraoperative glycemic management behaviors. AlertWatch (AlertWatch, USA) is a novel audiovisual alert system that serves as a secondary patient monitor for use in operating rooms. The authors evaluated the influence of use of AlertWatch on intraoperative glycemic management behavior. AlertWatch displays historical patient data (risk factors and laboratory results) from multiple networked information systems, combined with the patient's live physiologic data. The authors extracted intraoperative data for 19 months to evaluate the relationship between AlertWatch usage and initiation of insulin treatment for hyperglycemia. Outcome associations were adjusted for physical status, case duration, procedural complexity, emergent procedure, fasting BG value, home insulin therapy, patient age, and primary anesthetist. Overall, 2,341 patients had documented intraoperative hyperglycemia. Use of AlertWatch (791 of 2,341; 33.5%) was associated with 55% increase in insulin treatment (496 of 791 [62.7%] with and 817 of 1,550 [52.7%] without AlertWatch; adjusted odds ratio [95% CI], 1.55 [1.23 to 1.95]; P < 0.001) and 44% increase in BG recheck after insulin administration (407 of 791 [51.5%] with AlertWatch and 655 of 1,550 [42.3%] in controls; adjusted odds ratio [95% CI], 1.44 [1.14 to 1.81]; P = 0.002). AlertWatch is associated with a significant increase in desirable intraoperative glycemic management behavior and may help achieve tighter intraoperative glycemic control.

  3. [Intraoperative monitoring of oxygen tissue pressure: Applications in vascular neurosurgery].

    PubMed

    Arikan, Fuat; Vilalta, Jordi; Torne, Ramon; Chocron, Ivette; Rodriguez-Tesouro, Ana; Sahuquillo, Juan

    2014-01-01

    Ischemic lesions related to surgical procedures are a major cause of postoperative morbidity in patients with cerebral vascular disease. There are different systems of neuromonitoring to detect intraoperative ischemic events, including intraoperative monitoring of oxygen tissue pressure (PtiO2). The aim of this article was to describe, through the discussion of 4 cases, the usefulness of intraoperative PtiO2 monitoring during vascular neurosurgery. In presenting these cases, we demonstrate that monitoring PtiO2 is a reliable way to detect early ischemic events during surgical procedures. Continuous monitoring of PtiO2 in an area at risk allows the surgeon to resolve the cause of the ischemic event before it evolves to an established cerebral infarction. Copyright © 2014 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  4. Intra-Operative Frozen Sections for Ovarian Tumors – A Tertiary Center Experience

    PubMed Central

    Arshad, Nur Zaiti Md; Ng, Beng Kwang; Paiman, Noor Asmaliza Md; Mahdy, Zaleha Abdullah; Noor, Rushdan Mohd

    2018-01-01

    Background: Accuracy of diagnosis with intra-operative frozen sections is extremely important in the evaluation of ovarian tumors so that appropriate surgical procedures can be selected. Study design: All patients who with intra-operative frozen sections for ovarian masses in a tertiary center over nine years from June 2008 until April 2017 were reviewed. Frozen section diagnosis and final histopathological reports were compared. Main outcome measures: Sensitivity, specificity, positive and negative predictive values of intra-operative frozen section as compared to final histopathological results for ovarian tumors. Results: A total of 92 cases were recruited for final evaluation. The frozen section diagnoses were comparable with the final histopathological reports in 83.7% of cases. The sensitivity, specificity, positive predictive value and negative predictive value for benign and malignant ovarian tumors were 95.6%, 85.1%, 86.0% and 95.2% and 69.2%, 100%, 100% and 89.2% respectively. For borderline ovarian tumors, the sensitivity and specificity were 76.2% and 88.7%, respectively; the positive predictive value was 66.7% and the negative predictive value was 92.7%. Conclusion: The accuracy of intra-operative frozen section diagnoses for ovarian tumors is high and this approach remains a reliable option in assessing ovarian masses intra-operatively. PMID:29373916

  5. Intraoperative use of low-dose recombinant activated factor VII during thoracic aortic operations.

    PubMed

    Andersen, Nicholas D; Bhattacharya, Syamal D; Williams, Judson B; Fosbol, Emil L; Lockhart, Evelyn L; Patel, Mayur B; Gaca, Jeffrey G; Welsby, Ian J; Hughes, G Chad

    2012-06-01

    Numerous studies have supported the effectiveness of recombinant activated factor VII (rFVIIa) for the control of bleeding after cardiac procedures; however safety concerns persist. Here we report the novel use of intraoperative low-dose rFVIIa in thoracic aortic operations, a strategy intended to improve safety by minimizing rFVIIa exposure. Between July 2005 and December 2010, 425 consecutive patients at a single referral center underwent thoracic aortic operations with cardiopulmonary bypass (CPB); 77 of these patients received intraoperative low-dose rFVIIa (≤60 μg/kg) for severe coagulopathy after CPB. Propensity matching produced a cohort of 88 patients (44 received intraoperative low-dose rFVIIa and 44 controls) for comparison. Matched patients receiving intraoperative low-dose rFVIIa got an initial median dose of 32 μg/kg (interquartile range [IQR], 16-43 μg/kg) rFVIIa given 51 minutes (42-67 minutes) after separation from CPB. Patients receiving intraoperative low-dose rFVIIa demonstrated improved postoperative coagulation measurements (partial thromboplastin time 28.6 versus 31.5 seconds; p=0.05; international normalized ratio, 0.8 versus 1.2; p<0.0001) and received 50% fewer postoperative blood product transfusions (2.5 versus 5.0 units; p=0.05) compared with control patients. No patient receiving intraoperative low-dose rFVIIa required postoperative rFVIIa administration or reexploration for bleeding. Rates of stroke, thromboembolism, myocardial infarction, and other adverse events were equivalent between groups. Intraoperative low-dose rFVIIa led to improved postoperative hemostasis with no apparent increase in adverse events. Intraoperative rFVIIa administration in appropriately selected patients may correct coagulopathy early in the course of refractory blood loss and lead to improved safety through the use of smaller rFVIIa doses. Appropriately powered randomized studies are necessary to confirm the safety and efficacy of this approach

  6. Quantitative, spectrally-resolved intraoperative fluorescence imaging

    PubMed Central

    Valdés, Pablo A.; Leblond, Frederic; Jacobs, Valerie L.; Wilson, Brian C.; Paulsen, Keith D.; Roberts, David W.

    2012-01-01

    Intraoperative visual fluorescence imaging (vFI) has emerged as a promising aid to surgical guidance, but does not fully exploit the potential of the fluorescent agents that are currently available. Here, we introduce a quantitative fluorescence imaging (qFI) approach that converts spectrally-resolved data into images of absolute fluorophore concentration pixel-by-pixel across the surgical field of view (FOV). The resulting estimates are linear, accurate, and precise relative to true values, and spectral decomposition of multiple fluorophores is also achieved. Experiments with protoporphyrin IX in a glioma rodent model demonstrate in vivo quantitative and spectrally-resolved fluorescence imaging of infiltrating tumor margins for the first time. Moreover, we present images from human surgery which detect residual tumor not evident with state-of-the-art vFI. The wide-field qFI technique has broad implications for intraoperative surgical guidance because it provides near real-time quantitative assessment of multiple fluorescent biomarkers across the operative field. PMID:23152935

  7. Quantification of bone strength by intraoperative torque measurement: a technical note.

    PubMed

    Suhm, Norbert; Haenni, Markus; Schwyn, Ronald; Hirschmann, Michael; Müller, Andreas Marc

    2008-06-01

    Bone strength describes the resistance of bone against mechanical failure. Bone strength depends on both the amount of bone and the bone's quality, and the bone strength may be looked upon as a relevant parameter to judge an osteosynthesis' stability. Information about bone strength was barely available intraoperatively in the past. The previous work of our group reported on development and laboratory evaluation of mechanical torque measurement as a method for the intraoperative quantification of bone strength. With the clinical series presented here we intend to verify that the im gesamten Text DensiProbe instrumentation for intraoperative torque measurement and the related measurement method are eligible for intraoperative use based on the following criteria: application of the method may not create complications, the measurement can be performed by the surgeon himself and may only cause a limited increase in the procedure time. From December 2006 until May 2007 ten patients with a pertrochanteric femoral fracture or a lateral femoral neck fracture eligible for stabilization with DHS were included in the study after having received informed consent. Any medication and comorbidity that might have influenced bone quality or bone mineral density (BMD) in these patients was documented. Bone strength was intraoperatively measured with DensiProbe. Complications that were obviously related with torque measurement were documented as well as any deviation from the suggested procedure; 6 and 12 weeks postoperative follow-up included clinical and radiological examination. The time required for torque measurement, the overall operating time and the number of persons present in the operating room were protocolled. BMD values of the contralateral femoral neck were postoperatively assessed by dual energy X-ray absorptiometry (DEXA) and compared to intraoperative peak torque values measured by DensiProbe. No major complication was observed during intraoperative application of

  8. Patterns of radiotherapy infrastructure in Japan and in other countries with well-developed radiotherapy infrastructures.

    PubMed

    Nakamura, Katsumasa; Konishi, Kenta; Komatsu, Tetsuya; Sasaki, Tomonari; Shikama, Naoto

    2018-05-01

    In high-income countries, the number of radiotherapy machine per population reaches a sufficient level. However, the patterns of infrastructure of radiotherapy in high-income countries are not well known. Among 29 high-income countries with gross national income of $25,000 or more per capita, we selected 23 countries whose total number of newly diagnosed cancer patients in 2012 was reported in the Organisation for Economic Co-operation and Development Health Statistics 2017. The numbers of radiotherapy centers and teletherapy machines in each of these 23 countries were collected using the Dictionary of Radiotherapy Centers database. The number of cancer patients per teletherapy machine was 452.35-1398.22 (median 711.66) with a three-fold variation, whereas the number of cancer patients per radiotherapy center varied even more widely, from 826.16 to 5159.86 (median 2259.83) with a six-fold variation. The average number of teletherapy machines per radiotherapy center also ranged widely, from 1.24 to 8.29 (median 3.11) with a seven-fold variation. The number of teletherapy machines in each country was almost proportional to that of cancer patients, and the number of teletherapy machines per radiotherapy center was inversely related to the number of radiotherapy centers per cancer patients. The number of teletherapy machines per radiotherapy center in Japan was 1.24, the most fragmented among the high-income countries. The percentage of large radiotherapy centers having three or more teletherapy machines in Japan was the smallest among 23 high-income countries. Optimization of the radiotherapy infrastructure in Japan should be carefully considered.

  9. Use of Intraoperative Computed Tomography for Revisional Procedures in Patients with Complex Maxillofacial Trauma

    PubMed Central

    Singh, Mansher; Ricci, Joseph A.

    2015-01-01

    Background: In patients with panfacial fractures and distorted anatomic landmarks of zygomatic and orbital complex, there is a risk of zygomaticomaxillary complex (ZMC) malpositioning even with the best efforts for surgical repair. This results in increased number of additional procedures to achieve accurate positioning. Methods: We describe the usage of intraoperative C-arm cone-beam computed tomographic (CT) scan for ZMC malpositioning in a representative patient with panfacial fractures. Results: We have successfully used intraoperative CT scan for ZMC malpositioning in 3 patients. The representative patient had ZMC malposition after the initial attempt of surgical repair without any intraoperative imaging. On using intraoperative CT scan during the next attempt, we were able to reposition the ZMC accurately. Conclusions: Intraoperative CT scan might improve the accuracy of ZMC positioning and decrease the chances of potential additional surgeries. In patients with distorted anatomical landmarks and panfacial fractures, it can be especially helpful toward correcting ZMC malposition. PMID:26301152

  10. Relation between Birth Weight and Intraoperative Hemorrhage during Cesarean Section in Pregnancy with Placenta Previa.

    PubMed

    Soyama, Hiroaki; Miyamoto, Morikazu; Ishibashi, Hiroki; Takano, Masashi; Sasa, Hidenori; Furuya, Kenichi

    2016-01-01

    Placenta previa, one of the most severe obstetric complications, carries an increased risk of intraoperative massive hemorrhage. Several risk factors for intraoperative hemorrhage have been identified to date. However, the correlation between birth weight and intraoperative hemorrhage has not been investigated. Here we estimate the correlation between birth weight and the occurrence of intraoperative massive hemorrhage in placenta previa. We included all 256 singleton pregnancies delivered via cesarean section at our hospital because of placenta previa between 2003 and 2015. We calculated not only measured birth weights but also standard deviation values according to the Japanese standard growth curve to adjust for differences in gestational age. We assessed the correlation between birth weight and the occurrence of intraoperative massive hemorrhage (>1500 mL blood loss). Receiver operating characteristic curves were constructed to determine the cutoff value of intraoperative massive hemorrhage. Of 256 pregnant women with placenta previa, 96 (38%) developed intraoperative massive hemorrhage. Receiver-operating characteristic curves revealed that the area under the curve of the combination variables between the standard deviation of birth weight and intraoperative massive hemorrhage was 0.71. The cutoff value with a sensitivity of 81.3% and specificity of 55.6% was -0.33 standard deviation. The multivariate analysis revealed that a standard deviation of >-0.33 (odds ratio, 5.88; 95% confidence interval, 3.04-12.00), need for hemostatic procedures (odds ratio, 3.31; 95% confidence interval, 1.79-6.25), and placental adhesion (odds ratio, 12.68; 95% confidence interval, 2.85-92.13) were independent risk of intraoperative massive hemorrhage. In patients with placenta previa, a birth weight >-0.33 standard deviation was a significant risk indicator of massive hemorrhage during cesarean section. Based on this result, further studies are required to investigate whether

  11. Dosimetric and geometric evaluation of a hybrid strategy of offline adaptive planning and online image guidance for prostate cancer radiotherapy

    PubMed Central

    Liu, Han; Wu, Qiuwen

    2011-01-01

    For prostate cancer patients, online image-guided (IG) radiotherapy has been widely used in clinic to correct the translational inter-fractional motion at each treatment fraction. For uncertainties that cannot be corrected online, such as rotation and deformation of the target volume, margins are still required to be added to the clinical target volume (CTV) for the treatment planning. Offline adaptive radiotherapy has been implemented to optimize the treatment for each individual patient based on the measurements at early stages of treatment process. It has been shown that offline adaptive radiotherapy can effectively reduce the required margin. Recently a hybrid strategy of offline adaptive replanning and online IG was proposed and the geometric evaluation was performed. It was found that the planning margins can be further reduced by 1–2 mm compared to online IG only strategy. The purpose of this study was to investigate the dosimetric benefits of such hybrid strategy on the target and organs at risk (OARs). A total of 420 repeated helical computed tomography (HCT) scans from 28 patients were included in the study. Both low-risk patients (LRP, CTV = prostate) and intermediate-risk patients (IRP, CTV = prostate + seminal vesicles, SV) were included in the simulation. Two registration methods, based on center-of-mass (COM) shift of prostate only and prostate plus SV, were performed for IRP. The intensity modulated radiotherapy (IMRT) was used in the simulation. Criteria on both cumulative dose and fractional doses were evaluated. Furthermore, the geometric evaluation was extended to investigate the optimal number of fractions necessary to construct the internal target volume (ITV) for the hybrid strategy. The dosimetric margin improvement was smaller than its geometric counterpart and was in the range of 0 mm to 1 mm. The optimal number of fractions necessary for the ITV construction is 2 for LRP and 3–4 for IRP in a hypofractionation protocol. A new

  12. Intraoperative Mapping of Expressive Language Cortex Using Passive Real-Time Electrocorticography

    DTIC Science & Technology

    2016-08-26

    lsev ie r .com/ locate /ebcrCase ReportIntraoperative mapping of expressive language cortex using passive real-time electrocorticographyAmiLyn M...case report, we investigated the utility and practicality of passive intraoperative functional mapping of expressive language cortex using high...expressive lan- guage regions. In preparation of tumor resection, the patient underwent multiple functional language mapping procedures. We examined

  13. A new approach to delineating lymph node target volumes for post-operative radiotherapy in gastric cancer: A phase II trial.

    PubMed

    Haijun, Yu; Qiuji, Wu; Zhenming, Fu; Yong, Huang; Zhengkai, Liao; Conghua, Xie; Yunfeng, Zhou; Yahua, Zhong

    2015-08-01

    In the context of gastric cancer, lymph node target volume delineation for post-operative radiotherapy is currently built on the traditional system of dividing the stomach and 2-D treatment methods. Here, we have proposed a new delineation approach with irradiation indications for lymph node stations. Its safety and efficacy were evaluated in a phase II clinical trial. Fifty-four gastric cancer patients with D2 lymph node dissection received 2 cycles of FOLFOX4. They subsequently received concurrent chemoradiotherapy (45 Gy at 1.8 Gy per fraction, 5 fractions per week for 5 weeks) with a 5-fluorouracil/leucovorin regimen, followed by 4 additional FOLFOX4 cycles. The target volume included the remnant stomach, anastomosis site, tumor bed, and regional lymph nodes selected through our new approach by taking gastric arteries as references. The most common grade 3-4 adverse event was neutropenia (14.8%). Neutropenia, anemia, and nausea were common grade 1-2 toxicities. No treatment-related deaths occurred during treatment. The 3-year overall, disease-free, and locoregional recurrence-free survival rates were 81.6%, 70.2%, and 91.1%, respectively. Eight patients developed peritoneal or distant metastases. Using our new approach and irradiation indications, delineation of the target volume of post-operative lymph node stations was feasible and well tolerated after D2 resection in patients with gastric cancer. Copyright © 2015 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  14. Ion-induced nuclear radiotherapy

    DOEpatents

    Horn, K.M.; Doyle, B.L.

    1996-08-20

    Ion-induced Nuclear Radiotherapy (INRT) is a technique for conducting radiosurgery and radiotherapy with a very high degree of control over the spatial extent of the irradiated volume and the delivered dose. Based upon the concept that low energy, ion induced atomic and nuclear reactions can be used to produce highly energetic reaction products at the site of a tumor, the INRT technique is implemented through the use of a conduit-needle or tube which conducts a low energy ion beam to a position above or within the intended treatment area. At the end of the conduit-needle or tube is a specially fabricated target which, only when struck by the ion beam, acts as a source of energetic radiation products. The inherent limitations in the energy, and therefore range, of the resulting reaction products limits the spatial extent of irradiation to a pre-defined volume about the point of reaction. Furthermore, since no damage is done to tissue outside this irradiated volume, the delivered dose may be made arbitrarily large. INRT may be used both as a point-source of radiation at the site of a small tumor, or as a topical bath of radiation to broad areas of diseased tissue. 25 figs.

  15. Ion-induced nuclear radiotherapy

    DOEpatents

    Horn, Kevin M.; Doyle, Barney L.

    1996-01-01

    Ion-induced Nuclear Radiotherapy (INRT) is a technique for conducting radiosurgery and radiotherapy with a very high degree of control over the spatial extent of the irradiated volume and the delivered dose. Based upon the concept that low energy, ion induced atomic and nuclear reactions can be used to produce highly energetic reaction products at the site of a tumor, the INRT technique is implemented through the use of a conduit-needle or tube which conducts a low energy ion beam to a position above or within the intended treatment area. At the end of the conduit-needle or tube is a specially fabricated target which, only when struck by the ion beam, acts as a source of energetic radiation products. The inherent limitations in the energy, and therefore range, of the resulting reaction products limits the spatial extent of irradiation to a pre-defined volume about the point of reaction. Furthermore, since no damage is done to tissue outside this irradiated volume, the delivered dose may be made arbitrarily large. INRT may be used both as a point-source of radiation at the site of a small tumor, or as a topical bath of radiation to broad areas of diseased tissue.

  16. Diffusion tensor magnetic resonance imaging driven growth modeling for radiotherapy target definition in glioblastoma.

    PubMed

    Jensen, Morten B; Guldberg, Trine L; Harbøll, Anja; Lukacova, Slávka; Kallehauge, Jesper F

    2017-11-01

    The clinical target volume (CTV) in radiotherapy is routinely based on gadolinium contrast enhanced T1 weighted (T1w + Gd) and T2 weighted fluid attenuated inversion recovery (T2w FLAIR) magnetic resonance imaging (MRI) sequences which have been shown to over- or underestimate the microscopic tumor cell spread. Gliomas favor spread along the white matter fiber tracts. Tumor growth models incorporating the MRI diffusion tensors (DTI) allow to account more consistently for the glioma growth. The aim of the study was to investigate the potential of a DTI driven growth model to improve target definition in glioblastoma (GBM). Eleven GBM patients were scanned using T1w, T2w FLAIR, T1w + Gd and DTI. The brain was segmented into white matter, gray matter and cerebrospinal fluid. The Fisher-Kolmogorov growth model was used assuming uniform proliferation and a difference in white and gray matter diffusion of a ratio of 10. The tensor directionality was tested using an anisotropy weighting parameter set to zero (γ0) and twenty (γ20). The volumetric comparison was performed using Hausdorff distance, Dice similarity coefficient (DSC) and surface area. The median of the standard CTV (CTVstandard) was 180 cm 3 . The median surface area of CTVstandard was 211 cm 2 . The median surface area of respective CTV γ0 and CTV γ20 significantly increased to 338 and 376 cm 2 , respectively. The Hausdorff distance was greater than zero and significantly increased for both CTV γ0 and CTV γ20 with respective median of 18.7 and 25.2 mm. The DSC for both CTV γ0 and CTV γ20 were significantly below one with respective median of 0.74 and 0.72, which means that 74 and 72% of CTVstandard were included in CTV γ0 and CTV γ20, respectively. DTI driven growth models result in CTVs with a significantly increased surface area, a significantly increased Hausdorff distance and decreased overlap between the standard and model derived volume.

  17. Should Low Molecular Weight PSMA Targeted Ligands Get Bigger and Use Albumin Ligands for PSMA Targeting?

    PubMed

    Huang, Steve S; Heston, Warren D W

    2017-01-01

    Prostate Specific Membrane Antigen (PSMA) is strongly expressed in prostate cancer. Recently a number of low-molecular-weight inhibitors have demonstrated excellent PSMA targeting activity for both imaging as well as Lutecium-177 radiotherapy in human trials. The paper by Choy et al raises the question of whether we can further increase the effectiveness of PSMA targeted therapy by adding an albumin-binding entity to low-molecular-weight agents.

  18. Living donor right liver lobes: preoperative CT volumetric measurement for calculation of intraoperative weight and volume.

    PubMed

    Lemke, Arne-Jörn; Brinkmann, Martin Julius; Schott, Thomas; Niehues, Stefan Markus; Settmacher, Utz; Neuhaus, Peter; Felix, Roland

    2006-09-01

    To prospectively develop equations for the calculation of expected intraoperative weight and volume of a living donor's right liver lobe by using preoperative computed tomography (CT) for volumetric measurement. After medical ethics committee and state medical board approval, informed consent was obtained from eight female and eight male living donors (age range, 18-63 years) for participation in preoperative CT volumetric measurement of the right liver lobes by using the summation-of-area method. Intraoperatively, the graft was weighed, and the volume of the graft was determined by means of water displacement. Distributions of pre- and intraoperative data were depicted as Tukey box-and-whisker diagrams. Then, linear regressions were calculated, and the results were depicted as scatterplots. On the basis of intraoperative data, physical density of the parenchyma was calculated by dividing weight by volume of the graft. Preoperative measurement of grafts resulted in a mean volume of 929 mL +/- 176 (standard deviation); intraoperative mean weight and volume of the grafts were 774 g +/- 138 and 697 mL +/- 139, respectively. All corresponding pre- and intraoperative data correlated significantly (P < .001) with each other. Intraoperatively expected volume (V(intraop)) in millilliters and weight (W(intraop)) in grams can be calculated with the equations V(intra)(op) = (0.656 . V(preop)) + 87.629 mL and W(intra)(op) = (0.678 g/mL . V(preop)) + 143.704 g, respectively, where preoperative volume is V(preop) in milliliters. Physical density of transplanted liver lobes was 1.1172 g/mL +/- 0.1015. By using two equations developed from the data obtained in this study, expected intraoperative weight and volume can properly be determined from CT volumetric measurements. (c) RSNA, 2006.

  19. Clinical evaluation of a mobile digital specimen radiography system for intraoperative specimen verification.

    PubMed

    Wang, Yingbing; Ebuoma, Lilian; Saksena, Mansi; Liu, Bob; Specht, Michelle; Rafferty, Elizabeth

    2014-08-01

    Use of mobile digital specimen radiography systems expedites intraoperative verification of excised breast specimens. The purpose of this study was to evaluate the performance of a such a system for verifying targets. A retrospective review included 100 consecutive pairs of breast specimen radiographs. Specimens were imaged in the operating room with a mobile digital specimen radiography system and then with a conventional digital mammography system in the radiology department. Two expert reviewers independently scored each image for image quality on a 3-point scale and confidence in target visualization on a 5-point scale. A target was considered confidently verified only if both reviewers declared the target to be confidently detected. The 100 specimens contained a total of 174 targets, including 85 clips (49%), 53 calcifications (30%), 35 masses (20%), and one architectural distortion (1%). Although a significantly higher percentage of mobile digital specimen radiographs were considered poor quality by at least one reviewer (25%) compared with conventional digital mammograms (1%), 169 targets (97%), were confidently verified with mobile specimen radiography; 172 targets (98%) were verified with conventional digital mammography. Three faint masses were not confidently verified with mobile specimen radiography, and conventional digital mammography was needed for confirmation. One faint mass and one architectural distortion were not confidently verified with either method. Mobile digital specimen radiography allows high diagnostic confidence for verification of target excision in breast specimens across target types, despite lower image quality. Substituting this modality for conventional digital mammography can eliminate delays associated with specimen transport, potentially decreasing surgical duration and increasing operating room throughput.

  20. Intraoperative Tumoral Bleeding of Hypervascular Medulloblastoma after Ventricular Drainage: A Case Report.

    PubMed

    Ryu, Han-Seung; Jung, Tae-Young; Han, Moon-Soo; Kim, Seul-Ki; Lee, Kyung-Hwa

    2017-01-01

    We report a rare case of intraoperative tumoral bleeding of a hypervascular medulloblastoma. A 12-year-old girl presented with dizziness and nausea. Brain magnetic resonance (MR) images revealed an approximately 4.2-cm enhanced mass on the cerebellar vermis associated with mild perilesional edema and increased cerebral blood volume. Angiography showed tumoral staining and developed occipital and circular dural sinuses in the venous phase. A suboccipital craniotomy was performed. To relieve the intracranial pressure, cerebrospinal fluid (CSF) was drained via a lateral ventricular catheter in the occipital horn. During the opening of the dura, the brain swelling had progressed, and brain computed tomography revealed an intratumoral hemorrhage with brainstem compression. The patient was in a stuporous mental state. A reoperation was performed, and the mass was totally removed. The pathologic findings revealed a medulloblastoma with abnormal enlarged arterial vascular structures. Postoperatively, the patient recovered to an alert mental state. She underwent chemotherapy and radiotherapy. There was no recurrence after 1 year. Pre-resectional CSF drainage should not be routinely performed in posterior fossa tumors, especially with increased cerebral blood volume on MR perfusion images. Complete removal should be performed quickly while CSF drainage should be performed slowly. An intratumoral hemorrhage should be considered in posterior fossa tumors when severe brain swelling suddenly develops after CSF drainage. © 2016 S. Karger AG, Basel.

  1. Does the Surgical Apgar Score Measure Intraoperative Performance?

    PubMed Central

    Regenbogen, Scott E.; Lancaster, R. Todd; Lipsitz, Stuart R.; Greenberg, Caprice C.; Hutter, Matthew M.; Gawande, Atul A.

    2008-01-01

    Objective To evaluate whether Surgical Apgar Scores measure the relationship between intraoperative care and surgical outcomes. Summary Background Data With preoperative risk-adjustment now well-developed, the role of intraoperative performance in surgical outcomes may be considered. We previously derived and validated a ten-point Surgical Apgar Score—based on intraoperative blood loss, heart rate, and blood pressure—that effectively predicts major postoperative complications within 30 days of general and vascular surgery. This study evaluates whether the predictive value of this score comes solely from patients’ preoperative risk, or also measures care in the operating room. Methods Among a systematic sample of 4,119 general and vascular surgery patients at a major academic hospital, we constructed a detailed risk-prediction model including 27 patient-comorbidity and procedure-complexity variables, and computed patients’ propensity to suffer a major postoperative complication. We evaluated the prognostic value of patients’ Surgical Apgar Scores before and after adjustment for this preoperative risk. Results After risk-adjustment, the Surgical Apgar Score remained strongly correlated with postoperative outcomes (p<0.0001). Odds of major complications among average-scoring patients (scores 7–8) were equivalent to preoperative predictions (likelihood ratio (LR) 1.05, 95%CI 0.78–1.41), significantly decreased for those who achieved the best scores of 9–10 (LR 0.52, 95%CI 0.35–0.78), and were significantly poorer for those with low scores—LRs 1.60 (1.12–2.28) for scores 5–6, and 2.80 (1.50–5.21) for scores 0–4. Conclusions Even after accounting for fixed preoperative risk—due to patients’ acute condition, comorbidities and/or operative complexity—the Surgical Apgar Score appears to detect differences in intraoperative management that reduce odds of major complications by half, or increase them by nearly three-fold. PMID:18650644

  2. Intraoperative serum parathyroid hormone level is an indicator of hypocalcaemia in total thyroidectomy patients.

    PubMed

    Islam, M S; Sultana, T; Paul, D; Huq, A H M Z; Chowdhury, A A; Ferdous, C; Ahmed, A N N

    2012-12-01

    Postoperative hypocalcaemia is the most frequent and common complication after total thyroidectomy. It is necessary to diagnose or to predict hypocalcaemia immediately after total thyroidectomy for minimizing complications. A prospective observational study was carried out in the Department of Clinical Pathology in collaboration with Department of Microbiology & Immunology, Department of Surgery, Department of Otolaryngology, Bangabandhu Sheikh Mujib Medical University (BSMMU) and Department of Otolaryngology, Dhaka Medical College & Hospital (DMC&H), Dhaka, during the period of September 2010 to August 2011 to evaluate intraoperative (20 minutes after total thyroidectomy) parathyroid hormone (PTH) measurement as a predictor of post thyroidectomy hypocalcaemia. Total 65 patients were enrolled in this study those came for total thyroidectomy. Postoperative hypocalcaemia developed in 25 cases. Intraoperative PTH was assessed and significant correlation was found between intraoperative PTH level and development of hypocalcaemia. The sensitivity, specificity, accuracy, positive predictive value, negative predictive value of intraoperative serum PTH for prediction of post total thyroidectomy hypocalcaemia were 84.0%, 85.0%, 84.6%, 77.8%, and 89.5% respectively. Because of the high sensitivity, specificity and accuracy of intraoperative serum PTH of this study, the early prediction of hypocalcaemia could be made by single assay of intraoperative serum PTH level at 20 minutes after total thyroidectomy.

  3. The validation index: a new metric for validation of segmentation algorithms using two or more expert outlines with application to radiotherapy planning.

    PubMed

    Juneja, Prabhjot; Evans, Philp M; Harris, Emma J

    2013-08-01

    Validation is required to ensure automated segmentation algorithms are suitable for radiotherapy target definition. In the absence of true segmentation, algorithmic segmentation is validated against expert outlining of the region of interest. Multiple experts are used to overcome inter-expert variability. Several approaches have been studied in the literature, but the most appropriate approach to combine the information from multiple expert outlines, to give a single metric for validation, is unclear. None consider a metric that can be tailored to case-specific requirements in radiotherapy planning. Validation index (VI), a new validation metric which uses experts' level of agreement was developed. A control parameter was introduced for the validation of segmentations required for different radiotherapy scenarios: for targets close to organs-at-risk and for difficult to discern targets, where large variation between experts is expected. VI was evaluated using two simulated idealized cases and data from two clinical studies. VI was compared with the commonly used Dice similarity coefficient (DSCpair - wise) and found to be more sensitive than the DSCpair - wise to the changes in agreement between experts. VI was shown to be adaptable to specific radiotherapy planning scenarios.

  4. Standard and Nonstandard Craniospinal Radiotherapy Using Helical TomoTherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parker, William, E-mail: william@medphys.mcgill.c; Brodeur, Marylene; Roberge, David

    2010-07-01

    Purpose: To show the advantages of planning and delivering craniospinal radiotherapy with helical TomoTherapy (TomoTherapy Inc., Madison, WI) by presenting 4 cases treated at our institution. Methods and Materials: We first present a standard case of craniospinal irradiation in a patient with recurrent myxopapillary ependymoma (MPE) and follow this with 2 cases requiring differential dosing to multiple target volumes. One of these, a patient with recurrent medulloblastoma, required a lower dose to be delivered to the posterior fossa because the patient had been previously irradiated to the full dose, and the other required concurrent boosts to leptomeningeal metastases as partmore » of his treatment for newly diagnosed MPE. The final case presented is a patient with pronounced scoliosis who required spinal irradiation for recurrent MPE. Results: The four cases presented were planned and treated successfully with Helical Tomotherapy. Conclusions: Helical TomoTherapy delivers continuous arc-based intensity-modulated radiotherapy that gives high conformality and excellent dose homogeneity for the target volumes. Increased healthy tissue sparing is achieved at higher doses albeit at the expense of larger volumes of tissue receiving lower doses. Helical TomoTherapy allows for differential dosing of multiple targets, resulting in very elegant dose distributions. Daily megavoltage computed tomography imaging allows for precision of patient positioning, permitting a reduction in planning margins and increased healthy tissue sparing in comparison with standard techniques.« less

  5. Results of intraoperative electron beam radiotherapy containing multimodality treatment for locally unresectable T4 rectal cancer: a pooled analysis of the Mayo Clinic Rochester and Catharina Hospital Eindhoven

    PubMed Central

    Holman, Fabian A.; Haddock, Michael G.; Gunderson, Leonard L.; Kusters, Miranda; Nieuwenhuijzen, Grard A. P.; van den Berg, Hetty A.; Nelson, Heidi

    2016-01-01

    Background The aim of this study is to analyse the pooled results of intraoperative electron beam radiotherapy (IOERT) containing multimodality treatment of locally advanced T4 rectal cancer, initially unresectable for cure, from the Mayo Clinic, Rochester, USA (MCR) and Catharina Hospital, Eindhoven, The Netherlands (CHE), both major referral centers for locally advanced rectal cancer. A rectal tumor is called locally unresectable for cure if after full clinical work-up infiltration into the surrounding structures or organs has been demonstrated, which would result in positive surgical margins if resection was the initial component of treatment. This was the reason to refer these patients to the IOERT program of one of the centers. Methods In the period from 1981 to 2010, 417 patients with locally unresectable T4 rectal carcinomas at initial presentation were treated with multimodality treatment including IOERT at either one of the two centres. The preferred treatment approach was preoperative (chemo) radiation and intended radical surgery combined with IOERT. Risk factors for local recurrence (LR), cancer specific survival, disease free survival and distant metastases (DM) were assessed. Results A total of 306 patients (73%) underwent a R0 resection. LRs and metastases occurred more frequently after an R1-2 resection (P<0.001 and P<0.001 respectively). Preoperative chemoradiation (preop CRT) was associated with a higher probability of having a R0 resection. Waiting time after preoperative treatment was inversely related with the chance of developing a LR, especially after R+ resection. In 16% of all cases a LR developed. Five-year disease free survival and overall survival (OS) were 55% and 56% respectively. Conclusions An acceptable survival can be achieved in treatment of patients with initially unresectable T4 rectal cancer with combined modality therapy that includes preop CRT and IOERT. Completeness of the resection is the most important predictive and

  6. Multimodality image integration for radiotherapy treatment: an easy approach

    NASA Astrophysics Data System (ADS)

    Santos, Andres; Pascau, Javier; Desco, Manuel; Santos, Juan A.; Calvo, Felipe A.; Benito, Carlos; Garcia-Barreno, Rafael

    2001-05-01

    The interest of using combined MR and CT information for radiotherapy planning is well documented. However, many planning workstations do not allow to use MR images, nor import predefined contours. This paper presents a new simple approach for transferring segmentation results from MRI to a CT image that will be used for radiotherapy planning, using the same original CT format. CT and MRI images of the same anatomical area are registered using mutual information (MI) algorithm. Targets and organs at risk are segmented by the physician on the MR image, where their contours are easy to track. A locally developed software running on PC is used for this step, with several facilities for the segmentation process. The result is transferred onto the CT by slightly modifying up and down the original Hounsfield values of some points of the contour. This is enough to visualize the contour on the CT, but does not affect dose calculations. The CT is then stored using the original file format of the radiotherapy planning workstation, where the technician uses the segmented contour to design the correct beam positioning. The described method has been tested in five patients. Simulations and patient results show that the dose distribution is not affected by the small modification of pixels of the CT image, while the segmented structures can be tracked in the radiotherapy planning workstation-using adequate window/level settings. The presence of the physician is not requires at the planning workstation, and he/she can perform the segmentation process using his/her own PC. This new approach makes it possible to take advantage from the anatomical information present on the MRI and to transfer the segmentation to the CT used for planning, even when the planning workstation does not allow to import external contours. The physician can draw the limits of the target and areas at risk off-line, thus separating in time the segmentation and planning tasks and increasing the efficiency.

  7. The influence of bone density on the radiotherapy of cervix cancer

    NASA Astrophysics Data System (ADS)

    Soares, M. R.; Souza, D. N.

    2011-10-01

    Until the 1970s the irradiated region of a patient undergoing external beam radiotherapy was considered a homogeneous volume and a regular surface, with physical characteristics similar to water. With the improvement of medical imaging equipment, it has become possible to conduct planning in radiotherapy treatment that considers the heterogeneities and irregularities of a patient's anatomy. Consequently, such technological resources have brought greater accuracy to radiotherapy. In this study, we determined the variation in the average amount of absorbed dose on the target volume and at the point of prescription treatment by comparing the doses which were calculated in a planning system considering the patient both as a homogeneous, and as a heterogeneous medium. The results showed that when we take into account the volume of the upper vagina and cervix, and consider the pelvis as a heterogeneous medium, the calculated dose was under-estimated at some points in the studied volume with respect to the dose when this region was considered homogeneous.

  8. [Image-guided radiotherapy and partial delegation to radiotherapy technicians: Clermont-Ferrand experience].

    PubMed

    Loos, G; Moreau, J; Miroir, J; Benhaïm, C; Biau, J; Caillé, C; Bellière, A; Lapeyre, M

    2013-10-01

    The various image-guided radiotherapy techniques raise the question of how to achieve the control of patient positioning before irradiation session and sharing of tasks between radiation oncologists and radiotherapy technicians. We have put in place procedures and operating methods to make a partial delegation of tasks to radiotherapy technicians and secure the process in three situations: control by orthogonal kV imaging (kV-kV) of bony landmarks, control by kV-kV imaging of intraprostatic fiducial goldmarkers and control by cone beam CT (CBCT) imaging for prostate cancer. Significant medical overtime is required to control these three IGRT techniques. Because of their competence in imaging, these daily controls can be delegated to radiotherapy technicians. However, to secure the process, initial training and regular evaluation are essential. The analysis of the comparison of the use of kV/kV on bone structures allowed us to achieve a partial delegation of control to radiotherapy technicians. Controlling the positioning of the prostate through the use and automatic registration of fiducial goldmarkers allows better tracking of the prostate and can be easily delegated to radiotherapy technicians. The analysis of the use of daily cone beam CT for patients treated with intensity modulated irradiation is underway, and a comparison of practices between radiotherapy technicians and radiation oncologists is ongoing to know if a partial delegation of this control is possible. Copyright © 2013. Published by Elsevier SAS.

  9. Demand for radiotherapy in Spain.

    PubMed

    Rodríguez, A; Borrás, J M; López-Torrecilla, J; Algara, M; Palacios-Eito, A; Gómez-Caamaño, A; Olay, L; Lara, P C

    2017-02-01

    Assessing the demand for radiotherapy in Spain based on existing evidence to estimate the human resources and equipment needed so that every person in Spain has access to high-quality radiotherapy when they need it. We used data from the European Cancer Observatory on the estimated incidence of cancer in Spain in 2012, along with the evidence-based indications for radiotherapy developed by the Australian CCORE project, to obtain an optimal radiotherapy utilisation proportion (OUP) for each tumour. About 50.5 % of new cancers in Spain require radiotherapy at least once over the course of the disease. Additional demand for these services comes from reradiation therapy and non-melanoma skin cancer. Approximately, 25-30 % of cancer patients with an indication for radiotherapy do not receive it due to factors that include access, patient preference, familiarity with the treatment among physicians, and especially resource shortages, all of which contribute to its underutilisation. Radiotherapy is underused in Spain. The increasing incidence of cancer expected over the next decade and the greater frequency of reradiations necessitate the incorporation of radiotherapy demand into need-based calculations for cancer services planning.

  10. Characterization of spatial distortion in a 0.35 T MRI-guided radiotherapy system

    NASA Astrophysics Data System (ADS)

    Ginn, John S.; Agazaryan, Nzhde; Cao, Minsong; Baharom, Umar; Low, Daniel A.; Yang, Yingli; Gao, Yu; Hu, Peng; Lee, Percy; Lamb, James M.

    2017-06-01

    Spatial distortion results in image deformation that can degrade accurate targeting and dose calculations in MRI-guided adaptive radiotherapy. The authors present a comprehensive assessment of a 0.35 T MRI-guided radiotherapy system’s spatial distortion using two commercially-available phantoms with regularly spaced markers. Images of the spatial integrity phantoms were acquired using five clinical protocols on the MRI-guided radiotherapy machine with the radiotherapy gantry positioned at various angles. Software was developed to identify and localize all phantom markers using a template matching approach. Rotational and translational corrections were implemented to account for imperfect phantom alignment. Measurements were made to assess uncertainties arising from susceptibility artifacts, image noise, and phantom construction accuracy. For a clinical 3D imaging protocol with a 1.5 mm reconstructed slice thickness, 100% of spheres within a 50 mm radius of isocenter had a 3D deviation of 1 mm or less. Of the spheres within 100 mm of isocenter, 99.9% had a 3D deviation less than 1 mm. 94.8% and 100% of the spheres within 175 mm were found to be within 1 mm and 2 mm of the expected positions in 3D respectively. Maximum 3D distortions within 50 mm, 100 mm and 175 mm of isocenter were 0.76 mm, 1.15 mm and 1.88 mm respectively. Distortions present in images acquired using the real-time imaging sequence were less than 1 mm for 98.1% and 95.0% of the cylinders within 50 mm and 100 mm of isocenter. The corresponding maximum distortion in these regions was 1.10 mm and 1.67 mm. These results may be used to inform appropriate planning target volume (PTV) margins for 0.35 T MRI-guided radiotherapy. Observed levels of spatial distortion should be explicitly considered when using PTV margins of 3 mm or less or in the case of targets displaced from isocenter by more than 50 mm.

  11. Big Data Analytics for Prostate Radiotherapy.

    PubMed

    Coates, James; Souhami, Luis; El Naqa, Issam

    2016-01-01

    Radiation therapy is a first-line treatment option for localized prostate cancer and radiation-induced normal tissue damage are often the main limiting factor for modern radiotherapy regimens. Conversely, under-dosing of target volumes in an attempt to spare adjacent healthy tissues limits the likelihood of achieving local, long-term control. Thus, the ability to generate personalized data-driven risk profiles for radiotherapy outcomes would provide valuable prognostic information to help guide both clinicians and patients alike. Big data applied to radiation oncology promises to deliver better understanding of outcomes by harvesting and integrating heterogeneous data types, including patient-specific clinical parameters, treatment-related dose-volume metrics, and biological risk factors. When taken together, such variables make up the basis for a multi-dimensional space (the "RadoncSpace") in which the presented modeling techniques search in order to identify significant predictors. Herein, we review outcome modeling and big data-mining techniques for both tumor control and radiotherapy-induced normal tissue effects. We apply many of the presented modeling approaches onto a cohort of hypofractionated prostate cancer patients taking into account different data types and a large heterogeneous mix of physical and biological parameters. Cross-validation techniques are also reviewed for the refinement of the proposed framework architecture and checking individual model performance. We conclude by considering advanced modeling techniques that borrow concepts from big data analytics, such as machine learning and artificial intelligence, before discussing the potential future impact of systems radiobiology approaches.

  12. Big Data Analytics for Prostate Radiotherapy

    PubMed Central

    Coates, James; Souhami, Luis; El Naqa, Issam

    2016-01-01

    Radiation therapy is a first-line treatment option for localized prostate cancer and radiation-induced normal tissue damage are often the main limiting factor for modern radiotherapy regimens. Conversely, under-dosing of target volumes in an attempt to spare adjacent healthy tissues limits the likelihood of achieving local, long-term control. Thus, the ability to generate personalized data-driven risk profiles for radiotherapy outcomes would provide valuable prognostic information to help guide both clinicians and patients alike. Big data applied to radiation oncology promises to deliver better understanding of outcomes by harvesting and integrating heterogeneous data types, including patient-specific clinical parameters, treatment-related dose–volume metrics, and biological risk factors. When taken together, such variables make up the basis for a multi-dimensional space (the “RadoncSpace”) in which the presented modeling techniques search in order to identify significant predictors. Herein, we review outcome modeling and big data-mining techniques for both tumor control and radiotherapy-induced normal tissue effects. We apply many of the presented modeling approaches onto a cohort of hypofractionated prostate cancer patients taking into account different data types and a large heterogeneous mix of physical and biological parameters. Cross-validation techniques are also reviewed for the refinement of the proposed framework architecture and checking individual model performance. We conclude by considering advanced modeling techniques that borrow concepts from big data analytics, such as machine learning and artificial intelligence, before discussing the potential future impact of systems radiobiology approaches. PMID:27379211

  13. Influence of intraoperative hypotension on leaks after sleeve gastrectomy.

    PubMed

    Nienhuijs, Simon W; Kaymak, Uzay; Korsten, Erik; Buise, Marc P

    2016-01-01

    Leak after a sleeve gastrectomy (SG) is a severe complication. Risk factors, such as regional ischemia, increased intraluminal pressure, technical failure of the stapling device, and surgeon error, have been reported. It was hypothesized that intraoperative hypotension is another risk factor for leak, similar to that reported for colorectal surgery. Tertiary teaching hospital in The Netherlands. Results of a 7-year cohort of primary SGs were reviewed in relation to multiple intraoperative blood pressure measurements. The thresholds for the mean pressure were 40 to 70 mm Hg and for the systolic pressure 70 to 100 mm Hg. Only continuous episodes of 15 and 20 minutes were included. Twenty-four leaks were identified in a cohort of 1041 primary SGs. Episodes of systolic blood pressure<100 mm Hg for 15 min (P = .027) and 20 minutes (P = .008) were significantly related to a staple line leak. An episode of mean blood pressure<70 mm Hg for 20 min was significantly related to leak (P = .014). Episodes with lower thresholds of pressure occurred less frequently and revealed no significant differences. Other identified risk factors were smoking (P = .019), fast-track recovery program (P = .006), use of a tri-stapler (P = .004), and duration of surgery (P = .000). In a multivariate analysis, only intraoperative systolic pressure<100 mm Hg for 20 minutes remained significant (odds ratio, 2.45; P = .012). Intraoperative hypotension may contribute independently to a leak after SG. Copyright © 2016 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  14. [¹²³I]ICF01012 melanoma imaging and [¹³¹I]ICF01012 dosimetry allow adapted internal targeted radiotherapy in preclinical melanoma models.

    PubMed

    Viallard, Claire; Perrot, Yann; Boudhraa, Zied; Jouberton, Elodie; Miot-Noirault, Elisabeth; Bonnet, Mathilde; Besse, Sophie; Mishellany, Florence; Cayre, Anne; Maigne, Lydia; Rbah-Vidal, Latifa; D'Incan, Michel; Cachin, Florent; Chezal, Jean-Michel; Degoul, Françoise

    2015-01-01

    Melanin-targeting radiotracers are interesting tools for imaging and treatment of pigmented melanoma metastases. However, variation of the pigment concentration may alter the efficiency of such targeting. A clear assessment of both tumor melanin status and dosimetry are therefore prerequisites for internal radiotherapy of disseminated melanoma. The melanin tracer ICF01012 was labelled with iodine-123 for melanoma imaging in pigmented murine B16F0 and human SK-Mel 3 melanomas. In vivo imaging showed that the uptake of [(123)I]ICF01012 to melanomas correlated significantly with melanin content. Schedule treatment of 3 × 25 MBq [(131)I]ICF01012 significantly reduced SK-Mel 3 tumor growth and significantly increased the median survival in treated mice. For this protocol, the calculated delivered dose was 53.2 Gy. Radio-iodinated ICF01012 is a good candidate for both imaging and therapeutic purposes for patients with metastatic pigmented melanomas.

  15. An audit of intraoperative frozen section in Johor.

    PubMed

    Khoo, J J

    2004-03-01

    A 4-year-review was carried out on intraoperative frozen section consultations in Sultanah Aminah Hospital, Johor Bahru. Two hundred and fifteen specimens were received from 79 patients in the period between January 1999 and December 2002. An average of 2.72 specimens per patient was received. The overall diagnostic accuracy was high, 97.56%. The diagnoses were deferred in 4.65% of the specimens. False positive diagnoses were made in 3 specimens (1.46%) and false negative diagnoses in 2 specimens (0.98%). This gave an error rate of 2.44%. The main cause of error was incorrect interpretation of the pathologic findings. In the present study, frozen sections showed good sensitivity (97.98%) and specificity (97.16%). Despite its limitations, frozen section is still generally considered to be an accurate mode of intraoperative consultation to assist the surgeon in deciding the best therapeutic approach for his patient at the operating table. The use of frozen section with proper indications was cost-effective as it helped lower the number of reoperations. An audit of intraoperative frozen section from time to time serves as part of an ongoing quality assurance program and should be recommended where the service is available.

  16. Effect of beam arrangement on oral cavity dose in external beam radiotherapy of nasopharyngeal carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Vincent W.C.; Yang Zhining; Zhang Wuzhe

    This study compared the oral cavity dose between the routine 7-beam intensity-modulated radiotherapy (IMRT) beam arrangement and 2 other 7-beam IMRT with the conventional radiotherapy beam arrangements in the treatment of nasopharyngeal carcinoma (NPC). Ten NPC patients treated by the 7-beam routine IMRT technique (IMRT-7R) between April 2009 and June 2009 were recruited. Using the same computed tomography data, target information, and dose constraints for all the contoured structures, 2 IMRT plans with alternative beam arrangements (IMRT-7M and IMRT-7P) by avoiding the anterior facial beam and 1 conventional radiotherapy plan (CONRT) were computed using the Pinnacle treatment planning system. Dose-volumemore » histograms were generated for the planning target volumes (PTVs) and oral cavity from which the dose parameters and the conformity index of the PTV were recorded for dosimetric comparisons among the plans with different beam arrangements. The dose distributions to the PTVs were similar among the 3 IMRT beam arrangements, whereas the differences were significant between IMRT-7R and CONRT plans. For the oral cavity dose, the 3 IMRT beam arrangements did not show significant difference. Compared with IMRT-7R, CONRT plan showed a significantly lower mean dose, V30 and V-40, whereas the V-60 was significantly higher. The 2 suggested alternative beam arrangements did not significantly reduce the oral cavity dose. The impact of varying the beam angles in IMRT of NPC did not give noticeable effect on the target and oral cavity. Compared with IMRT, the 2-D conventional radiotherapy irradiated a greater high-dose volume in the oral cavity.« less

  17. Minimally Invasive Spinal Surgery with Intraoperative Image-Guided Navigation

    PubMed Central

    Kim, Terrence T.; Johnson, J. Patrick; Pashman, Robert; Drazin, Doniel

    2016-01-01

    We present our perioperative minimally invasive spine surgery technique using intraoperative computed tomography image-guided navigation for the treatment of various lumbar spine pathologies. We present an illustrative case of a patient undergoing minimally invasive percutaneous posterior spinal fusion assisted by the O-arm system with navigation. We discuss the literature and the advantages of the technique over fluoroscopic imaging methods: lower occupational radiation exposure for operative room personnel, reduced need for postoperative imaging, and decreased revision rates. Most importantly, we demonstrate that use of intraoperative cone beam CT image-guided navigation has been reported to increase accuracy. PMID:27213152

  18. Venetoclax Synergizes with Radiotherapy for Treatment of B-cell Lymphomas.

    PubMed

    O'Steen, Shyril; Green, Damian J; Gopal, Ajay K; Orozco, Johnnie J; Kenoyer, Aimee L; Lin, Yukang; Wilbur, D Scott; Hamlin, Donald K; Fisher, Darrell R; Hylarides, Mark D; Gooley, Theodore A; Waltman, Amelia; Till, Brian G; Press, Oliver W

    2017-07-15

    Constitutive B-cell receptor signaling leads to overexpression of the antiapoptotic BCL-2 protein and is implicated in the pathogenesis of many types of B-cell non-Hodgkin lymphoma (B-NHL). The BCL-2 small-molecule inhibitor venetoclax shows promising clinical response rates in several lymphomas, but is not curative as monotherapy. Radiotherapy is a rational candidate for combining with BCL-2 inhibition, as DNA damage caused by radiotherapy increases the activity of pro-apoptotic BCL-2 pathway proteins, and lymphomas are exquisitely sensitive to radiation. We tested B-NHL responses to venetoclax combined with either external beam radiotherapy or radioimmunotherapy (RIT), which joins the selectivity of antibody targeting with the effectiveness of irradiation. We first tested cytotoxicity of cesium-137 irradiation plus venetoclax in 14 B-NHL cell lines representing five lymphoma subtypes. Combination treatment synergistically increased cell death in 10 of 14 lines. Lack of synergy was predicted by resistance to single-agent venetoclax and high BCL-XL expression. We then assessed the efficacy of external beam radiotherapy plus venetoclax in murine xenograft models of mantle cell (MCL), germinal-center diffuse large B-cell (GCB-DLBCL), and activated B-cell (ABC-DLBCL) lymphomas. In each model, external beam radiotherapy plus venetoclax synergistically increased mouse survival time, curing up to 10%. We finally combined venetoclax treatment of MCL and ABC-DLBCL xenografts with a pretargeted RIT (PRIT) system directed against the CD20 antigen. Optimal dosing of PRIT plus venetoclax cured 100% of mice with no detectable toxicity. Venetoclax combined with radiotherapy may be a promising treatment for a wide range of lymphomas Cancer Res; 77(14); 3885-93. ©2017 AACR . ©2017 American Association for Cancer Research.

  19. Intraoperative confocal microscopy in the visualization of 5-aminolevulinic acid fluorescence in low-grade gliomas.

    PubMed

    Sanai, Nader; Snyder, Laura A; Honea, Norissa J; Coons, Stephen W; Eschbacher, Jennifer M; Smith, Kris A; Spetzler, Robert F

    2011-10-01

    Greater extent of resection (EOR) for patients with low-grade glioma (LGG) corresponds with improved clinical outcome, yet remains a central challenge to the neurosurgical oncologist. Although 5-aminolevulinic acid (5-ALA)-induced tumor fluorescence is a strategy that can improve EOR in gliomas, only glioblastomas routinely fluoresce following 5-ALA administration. Intraoperative confocal microscopy adapts conventional confocal technology to a handheld probe that provides real-time fluorescent imaging at up to 1000× magnification. The authors report a combined approach in which intraoperative confocal microscopy is used to visualize 5-ALA tumor fluorescence in LGGs during the course of microsurgical resection. Following 5-ALA administration, patients with newly diagnosed LGG underwent microsurgical resection. Intraoperative confocal microscopy was conducted at the following points: 1) initial encounter with the tumor; 2) the midpoint of tumor resection; and 3) the presumed brain-tumor interface. Histopathological analysis of these sites correlated tumor infiltration with intraoperative cellular tumor fluorescence. Ten consecutive patients with WHO Grades I and II gliomas underwent microsurgical resection with 5-ALA and intraoperative confocal microscopy. Macroscopic tumor fluorescence was not evident in any patient. However, in each case, intraoperative confocal microscopy identified tumor fluorescence at a cellular level, a finding that corresponded to tumor infiltration on matched histological analyses. Intraoperative confocal microscopy can visualize cellular 5-ALA-induced tumor fluorescence within LGGs and at the brain-tumor interface. To assess the clinical value of 5-ALA for high-grade gliomas in conjunction with neuronavigation, and for LGGs in combination with intraoperative confocal microscopy and neuronavigation, a Phase IIIa randomized placebo-controlled trial (BALANCE) is underway at the authors' institution.

  20. Conversion coefficients for determination of dispersed photon dose during radiotherapy: NRUrad input code for MCNP.

    PubMed

    Shahmohammadi Beni, Mehrdad; Ng, C Y P; Krstic, D; Nikezic, D; Yu, K N

    2017-01-01

    Radiotherapy is a common cancer treatment module, where a certain amount of dose will be delivered to the targeted organ. This is achieved usually by photons generated by linear accelerator units. However, radiation scattering within the patient's body and the surrounding environment will lead to dose dispersion to healthy tissues which are not targets of the primary radiation. Determination of the dispersed dose would be important for assessing the risk and biological consequences in different organs or tissues. In the present work, the concept of conversion coefficient (F) of the dispersed dose was developed, in which F = (Dd/Dt), where Dd was the dispersed dose in a non-targeted tissue and Dt is the absorbed dose in the targeted tissue. To quantify Dd and Dt, a comprehensive model was developed using the Monte Carlo N-Particle (MCNP) package to simulate the linear accelerator head, the human phantom, the treatment couch and the radiotherapy treatment room. The present work also demonstrated the feasibility and power of parallel computing through the use of the Message Passing Interface (MPI) version of MCNP5.

  1. Conversion coefficients for determination of dispersed photon dose during radiotherapy: NRUrad input code for MCNP

    PubMed Central

    Krstic, D.; Nikezic, D.

    2017-01-01

    Radiotherapy is a common cancer treatment module, where a certain amount of dose will be delivered to the targeted organ. This is achieved usually by photons generated by linear accelerator units. However, radiation scattering within the patient’s body and the surrounding environment will lead to dose dispersion to healthy tissues which are not targets of the primary radiation. Determination of the dispersed dose would be important for assessing the risk and biological consequences in different organs or tissues. In the present work, the concept of conversion coefficient (F) of the dispersed dose was developed, in which F = (Dd/Dt), where Dd was the dispersed dose in a non-targeted tissue and Dt is the absorbed dose in the targeted tissue. To quantify Dd and Dt, a comprehensive model was developed using the Monte Carlo N-Particle (MCNP) package to simulate the linear accelerator head, the human phantom, the treatment couch and the radiotherapy treatment room. The present work also demonstrated the feasibility and power of parallel computing through the use of the Message Passing Interface (MPI) version of MCNP5. PMID:28362837

  2. Intraoperative Ultrasound Technology in Neuro-Oncology Practice-Current Role and Future Applications.

    PubMed

    Moiyadi, Aliasgar V

    2016-09-01

    Surgery for cranial and spinal tumors has evolved tremendously over the years. Not only have neuro-oncologists been able to better understand tumor biology and thereby improve multimodality therapy, but advances in surgical techniques have also directly equipped neurosurgeons with the armamentarium necessary to achieve more radical resections safely. Intraoperative imaging tools are one such adjunct. Though intraoperative magnetic resonance (MR) has emerged as the "gold standard" among these, logistical challenges make it difficult to implement across all centers. On the other hand, the use of ultrasound (US) intraoperatively predates the use of MR. Over the past 4 decades, technologic improvements have refined and expanded the scope and application of intraoperative US technology. Strategies to maximize its efficacy and overcome the various limitations have evolved. A large volume of clinical experience has accumulated with respect to its role as an adjunct specifically in tumor surgery. We performed a literature review to evaluate the role of IOUS in tumor surgery. This review traces the evolution of intraoperative US over the years and reviews the current scope and applications with respect to neuro-oncologic surgery, as well as potential future applications. IOUS has evolved over the years since its introduction. Advances in technology have provided real-time navigated and 3-D techniques, which overcome many of the limitations of older IOUS techniques. This has shown to be very useful in not only localization of lesions, but also in improving resection rates as well as survival. IOUS is a powerful and versatile multipurpose intraoperative adjunct in tumor surgery, especially for resection control. The learning curve is relatively easy to climb and future improvements in technology are likely to widen the scope of its use. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Intraoperative Evaluation of Reverse Bypass Using a Naturally Formed "Bonnet" Superficial Temporal Artery: Technical Note.

    PubMed

    Nagm, Alhusain; Horiuchi, Tetsuyoshi; Hasegawa, Takatoshi; Hongo, Kazuhiro

    2016-04-01

    In reverse bypass that used a naturally formed "bonnet" superficial temporal artery, intraoperative volume flow measurement quantifies flow augmentation after revascularization, confirms flow preservation, and identifies inadvertent vessel compromise. A 75-year-old man presented with transient ischemic attacks attributed to right internal carotid artery stenosis. He underwent successful reverse bypass via a naturally formed "bonnet" superficial temporal artery middle cerebral artery bypass. As the result of proper intraoperative volume flow evaluation, a successful reverse bypass was achieved. Modification of the intraoperative stroke risk and prediction of the long-term patency after reverse bypass can be achieved by meticulous intraoperative blood flow evaluation. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. High-performance intraoperative cone-beam CT on a mobile C-arm: an integrated system for guidance of head and neck surgery

    NASA Astrophysics Data System (ADS)

    Siewerdsen, J. H.; Daly, M. J.; Chan, H.; Nithiananthan, S.; Hamming, N.; Brock, K. K.; Irish, J. C.

    2009-02-01

    A system for intraoperative cone-beam CT (CBCT) surgical guidance is under development and translation to trials in head and neck surgery. The system provides 3D image updates on demand with sub-millimeter spatial resolution and soft-tissue visibility at low radiation dose, thus overcoming conventional limitations associated with preoperative imaging alone. A prototype mobile C-arm provides the imaging platform, which has been integrated with several novel subsystems for streamlined implementation in the OR, including: real-time tracking of surgical instruments and endoscopy (with automatic registration of image and world reference frames); fast 3D deformable image registration (a newly developed multi-scale Demons algorithm); 3D planning and definition of target and normal structures; and registration / visualization of intraoperative CBCT with the surgical plan, preoperative images, and endoscopic video. Quantitative evaluation of surgical performance demonstrates a significant advantage in achieving complete tumor excision in challenging sinus and skull base ablation tasks. The ability to visualize the surgical plan in the context of intraoperative image data delineating residual tumor and neighboring critical structures presents a significant advantage to surgical performance and evaluation of the surgical product. The system has been translated to a prospective trial involving 12 patients undergoing head and neck surgery - the first implementation of the research prototype in the clinical setting. The trial demonstrates the value of high-performance intraoperative 3D imaging and provides a valuable basis for human factors analysis and workflow studies that will greatly augment streamlined implementation of such systems in complex OR environments.

  5. Intra-operative cardiac monitoring by trans-oesophageal Doppler is not risk free in surgical patients.

    PubMed

    Siddiqui, Muhammad Rafay Sameen; Sajid, Muhammad Shafiq; Baig, Mirza Khurram

    2009-04-01

    The advancement of medical technology and future improvements in public health will lead to surgeons operating on high risk patients. One of these advances is to use intra-operative trans-oesophageal Doppler (TOD) to optimise fluid management. TOD is known to be the most effective technique for intraoperative cardiac monitoring. We report a case of a potentially life threatening complication from intraoperative TOD monitoring.

  6. The utility of intraoperative ultrasound in modified radical neck dissection: a pilot study.

    PubMed

    Agcaoglu, Orhan; Aliyev, Shamil; Taskin, Halit Eren; Aksoy, Erol; Siperstein, Allan; Berber, Eren

    2014-04-01

    Although the value of surgeon-performed neck ultrasound (SPUS) for thyroid nodules has been validated, the utility of intraoperative ultrasound (US) in modified radical neck dissection (MRND) has not been reported in the literature. The aim of this study was to analyze the utility of intraoperative SPUS in assessing the completeness of MRND for thyroid cancer. Between 2007 and 2011, a total of 25 patients underwent MRND by 1 surgeon for thyroid cancer. All patients underwent intraoperative SPUS, which was repeated at the end of the neck dissection (completion US) to look for missed lymph nodes (LNs). There were 10 male and 15 female patients. Pathology included 23 papillary and 2 medullary carcinomas. The number of LNs removed per case was 23 ± 2, and the number of positive was LNs 5 ± 1. In 4 (16%) cases, intraoperative US detected 7 residual LNs, which would have been missed, if completion US were not done. These missed LNs were located in low-level IV (3 nodes), high-level II (2 nodes), and posterior level V (2 nodes) and measured 1.4 ± 0.2 cm. At follow-up, recurrence was seen in 2 (8%) patients, including a superior mediastinal recurrence in a patient with tall cell cancer and a jugular LN recurrence at level II in another patient with papillary thyroid cancer. This pilot study shows that intraoperative SPUS can help assess the completeness of MRND. According to our results, intraoperative completion US identifies LNs missed by palpation 16% of the time.

  7. Intraoperative positioning of the hindfoot with the hindfoot alignment guide: a pilot study.

    PubMed

    Frigg, Arno; Jud, Lukas; Valderrabano, Victor

    2014-01-01

    In a previous study, intraoperative positioning of the hindfoot by visual means resulted in the wrong varus/valgus position by 8 degrees and a relatively large standard deviation of 8 degrees. Thus, new intraoperative means are needed to improve the precision of hindfoot surgery. We therefore sought a hindfoot alignment guide that would be as simple as the alignment guides used in total knee arthroplasty. A novel hindfoot alignment guide (HA guide) has been developed that projects the mechanical axis from the tibia down to the heel. The HA guide enables the positioning of the hindfoot in the desired varus/valgus position and in plantigrade position in the lateral plane. The HA guide was used intraoperatively from May through November 2011 in 11 complex patients with simultaneous correction of the supramalleolar, tibiotalar, and inframalleolar alignment. Pre- and postoperative Saltzman views were taken and the position was measured. The HA guide significantly improved the intraoperative positioning compared with visual means: The accuracy with the HA guide was 4.5 ± 5.1 degrees (mean ± standard deviation) and without the HA guide 9.4 ± 5.5 degrees (P < .05). In 7 of 11 patients, the preoperative plan was changed because of the HA guide (2 avoided osteotomies, 5 additional osteotomies). The HA guide helped to position the hindfoot intraoperatively with greater precision than visual means. The HA guide was especially useful for multilevel corrections in which the need for and the amount of a simultaneous osteotomy had to be evaluated intraoperatively. Level IV, case series.

  8. Intraoperative Ultrasound in Patients Undergoing Transsphenoidal Surgery for Pituitary Adenoma: Systematic Review [corrected].

    PubMed

    Marcus, Hani J; Vercauteren, Tom; Ourselin, Sebastien; Dorward, Neil L

    2017-10-01

    Transsphenoidal surgery is the gold standard for pituitary adenoma resection. However, despite advances in microsurgical and endoscopic techniques, some pituitary adenomas can be challenging to cure. We sought to determine whether, in patients undergoing transsphenoidal surgery for pituitary adenoma, intraoperative ultrasound is a safe and effective technologic adjunct. The PubMed database was searched between January 1996 and January 2016 to identify relevant publications that 1) featured patients undergoing transsphenoidal surgery for pituitary adenoma, 2) used intraoperative ultrasound, and 3) reported on safety or effectiveness. Reference lists were also checked, and expert opinions were sought to identify further publications. Ultimately, 10 studies were included, comprising 1 cohort study, 7 case series, and 2 case reports. One study reported their prototype probe malfunctioned, leading to false-positive results in 2 cases, and another study' prototype probe was too large to safely enter the sphenoid sinus in 2 cases. Otherwise, no safety issues directly related to use of intraoperative ultrasound were reported. In the only comparative study, remission occurred in 89.7% (61/68) of patients with Cushing disease in whom intraoperative ultrasound was used, compared with 83.8% (57/68) in whom it was not. All studies reported that surgeons anecdotally found intraoperative ultrasound helpful. Although there is limited and low-quality evidence available, the use of intraoperative ultrasound appears to be a safe and effective technologic adjunct to transsphenoidal surgery for pituitary adenoma. Advances in ultrasound technology may allow for more widespread use of such devices. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Intraoperative 3-Dimensional Computed Tomography and Navigation in Foot and Ankle Surgery.

    PubMed

    Chowdhary, Ashwin; Drittenbass, Lisca; Dubois-Ferrière, Victor; Stern, Richard; Assal, Mathieu

    2016-09-01

    Computer-assisted orthopedic surgery has developed dramatically during the past 2 decades. This article describes the use of intraoperative 3-dimensional computed tomography and navigation in foot and ankle surgery. Traditional imaging based on serial radiography or C-arm-based fluoroscopy does not provide simultaneous real-time 3-dimensional imaging, and thus leads to suboptimal visualization and guidance. Three-dimensional computed tomography allows for accurate intraoperative visualization of the position of bones and/or navigation implants. Such imaging and navigation helps to further reduce intraoperative complications, leads to improved surgical outcomes, and may become the gold standard in foot and ankle surgery. [Orthopedics.2016; 39(5):e1005-e1010.]. Copyright 2016, SLACK Incorporated.

  10. Relation between Birth Weight and Intraoperative Hemorrhage during Cesarean Section in Pregnancy with Placenta Previa

    PubMed Central

    Ishibashi, Hiroki; Takano, Masashi; Sasa, Hidenori; Furuya, Kenichi

    2016-01-01

    Background Placenta previa, one of the most severe obstetric complications, carries an increased risk of intraoperative massive hemorrhage. Several risk factors for intraoperative hemorrhage have been identified to date. However, the correlation between birth weight and intraoperative hemorrhage has not been investigated. Here we estimate the correlation between birth weight and the occurrence of intraoperative massive hemorrhage in placenta previa. Materials and Methods We included all 256 singleton pregnancies delivered via cesarean section at our hospital because of placenta previa between 2003 and 2015. We calculated not only measured birth weights but also standard deviation values according to the Japanese standard growth curve to adjust for differences in gestational age. We assessed the correlation between birth weight and the occurrence of intraoperative massive hemorrhage (>1500 mL blood loss). Receiver operating characteristic curves were constructed to determine the cutoff value of intraoperative massive hemorrhage. Results Of 256 pregnant women with placenta previa, 96 (38%) developed intraoperative massive hemorrhage. Receiver-operating characteristic curves revealed that the area under the curve of the combination variables between the standard deviation of birth weight and intraoperative massive hemorrhage was 0.71. The cutoff value with a sensitivity of 81.3% and specificity of 55.6% was −0.33 standard deviation. The multivariate analysis revealed that a standard deviation of >−0.33 (odds ratio, 5.88; 95% confidence interval, 3.04–12.00), need for hemostatic procedures (odds ratio, 3.31; 95% confidence interval, 1.79–6.25), and placental adhesion (odds ratio, 12.68; 95% confidence interval, 2.85–92.13) were independent risk of intraoperative massive hemorrhage. Conclusion In patients with placenta previa, a birth weight >−0.33 standard deviation was a significant risk indicator of massive hemorrhage during cesarean section. Based on

  11. Feasibility of Adaptive MR-guided Stereotactic Body Radiotherapy (SBRT) of Lung Tumors

    PubMed Central

    Simpson, Garrett N; Llorente, Ricardo; Samuels, Michael A; Dogan, Nesrin

    2018-01-01

    Online adaptive radiotherapy (ART) with frequent imaging has the potential to improve dosimetric accuracy by accounting for anatomical and functional changes during the course of radiotherapy. Presented are three interesting cases that provide an assessment of online adaptive magnetic resonance-guided radiotherapy (MRgRT) for lung stereotactic body radiotherapy (SBRT). The study includes three lung SBRT cases, treated on an MRgRT system where MR images were acquired for planning and prior to each treatment fraction. Prescription dose ranged from 48 to 50 Gy in four to five fractions, normalized to where 95% of the planning target volume (PTV) was covered by 100% of the prescription dose. The process begins with the gross tumor volume (GTV), PTV, spinal cord, lungs, heart, and esophagus being delineated on the planning MRI. The treatment plan was then generated using a step-and-shoot intensity modulated radiotherapy (IMRT) technique, which utilized a Monte Carlo dose calculation. Next, the target and organs at risk (OAR) contours from the planning MRI were deformably propagated to the daily setup MRIs. These deformed contours were reviewed and modified by the physician. To determine the efficacy of ART, two different strategies were explored: 1) Calculating the plan created for the planning MR on each fraction setup MR dataset (Non-Adapt) and 2) creating a new optimized IMRT plan on the fraction setup MR dataset (FxAdapt). The treatment plans from both strategies were compared using the clinical dose-volume constraints. PTV coverage constraints were not met for 33% Non-Adapt fractions; all FxAdapt fractions met this constraint. Eighty-eight percent of all OAR constraints studied were better on FxAdapt plans, while 12% of OAR constraints were superior on Non-Adapt fractions. The OAR that garnered the largest benefit would be the uninvolved lung, with superior sparing in 92% of the FxAdapt studied. Similar, but less pronounced, benefits from adaptive planning were

  12. Validation of model-based deformation correction in image-guided liver surgery via tracked intraoperative ultrasound: preliminary method and results

    NASA Astrophysics Data System (ADS)

    Clements, Logan W.; Collins, Jarrod A.; Wu, Yifei; Simpson, Amber L.; Jarnagin, William R.; Miga, Michael I.

    2015-03-01

    Soft tissue deformation represents a significant error source in current surgical navigation systems used for open hepatic procedures. While numerous algorithms have been proposed to rectify the tissue deformation that is encountered during open liver surgery, clinical validation of the proposed methods has been limited to surface based metrics and sub-surface validation has largely been performed via phantom experiments. Tracked intraoperative ultrasound (iUS) provides a means to digitize sub-surface anatomical landmarks during clinical procedures. The proposed method involves the validation of a deformation correction algorithm for open hepatic image-guided surgery systems via sub-surface targets digitized with tracked iUS. Intraoperative surface digitizations were acquired via a laser range scanner and an optically tracked stylus for the purposes of computing the physical-to-image space registration within the guidance system and for use in retrospective deformation correction. Upon completion of surface digitization, the organ was interrogated with a tracked iUS transducer where the iUS images and corresponding tracked locations were recorded. After the procedure, the clinician reviewed the iUS images to delineate contours of anatomical target features for use in the validation procedure. Mean closest point distances between the feature contours delineated in the iUS images and corresponding 3-D anatomical model generated from the preoperative tomograms were computed to quantify the extent to which the deformation correction algorithm improved registration accuracy. The preliminary results for two patients indicate that the deformation correction method resulted in a reduction in target error of approximately 50%.

  13. Multivariate analysis for the estimation of target localization errors in fiducial marker-based radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takamiya, Masanori; Nakamura, Mitsuhiro, E-mail: m-nkmr@kuhp.kyoto-u.ac.jp; Akimoto, Mami

    Purpose: To assess the target localization error (TLE) in terms of the distance between the target and the localization point estimated from the surrogates (|TMD|), the average of respiratory motion for the surrogates and the target (|aRM|), and the number of fiducial markers used for estimating the target (n). Methods: This study enrolled 17 lung cancer patients who subsequently underwent four fractions of real-time tumor tracking irradiation. Four or five fiducial markers were implanted around the lung tumor. The three-dimensional (3D) distance between the tumor and markers was at maximum 58.7 mm. One of the markers was used as themore » target (P{sub t}), and those markers with a 3D |TMD{sub n}| ≤ 58.7 mm at end-exhalation were then selected. The estimated target position (P{sub e}) was calculated from a localization point consisting of one to three markers except P{sub t}. Respiratory motion for P{sub t} and P{sub e} was defined as the root mean square of each displacement, and |aRM| was calculated from the mean value. TLE was defined as the root mean square of each difference between P{sub t} and P{sub e} during the monitoring of each fraction. These procedures were performed repeatedly using the remaining markers. To provide the best guidance on the answer with n and |TMD|, fiducial markers with a 3D |aRM ≥ 10 mm were selected. Finally, a total of 205, 282, and 76 TLEs that fulfilled the 3D |TMD| and 3D |aRM| criteria were obtained for n = 1, 2, and 3, respectively. Multiple regression analysis (MRA) was used to evaluate TLE as a function of |TMD| and |aRM| in each n. Results: |TMD| for n = 1 was larger than that for n = 3. Moreover, |aRM| was almost constant for all n, indicating a similar scale for the marker’s motion near the lung tumor. MRA showed that |aRM| in the left–right direction was the major cause of TLE; however, the contribution made little difference to the 3D TLE because of the small amount of motion in the left–right direction

  14. Intraocular lens power selection and positioning with and without intraoperative aberrometry.

    PubMed

    Hatch, Kathryn M; Woodcock, Emily C; Talamo, Jonathan H

    2015-04-01

    To determine the value of intraoperative aberrometry in cases of toric intraocular lens (IOL) implantation and positioning. In this non-randomized retrospective comparative trial, two groups of eyes underwent cataract extraction with toric IOL implantation: the aberrometry group (n = 37 eyes), where toric IOL power and alignment were determined before surgery with automated keratometry, standard optical biometry, and an online calculator and then refined using intraoperative aberrometry, and the toric calculator group (n = 27 eyes), where IOL selection was performed in a similar manner but without intraoperative aberrometry. The primary outcome measure was mean postoperative residual refractive astigmatism (RRA). Mean RRA measured at follow-up after surgery was 0.46 ± 0.42 and 0.68 ± 0.34 diopters (D) in the aberrometry and toric calculator groups, respectively (P = .0153). A 75% and 57% reduction in cylinder was noted between preoperative keratometric astigmatism and postoperative RRA in the aberrometry and toric calculator groups, respectively (P = .0027). RRA of 0.25 D or less, 0.50 D or less, 0.75 D or less, and 1.00 D or less was seen 38%, 78%, 86%, and 95% of the time, respectively, in the aberrometry group and 22%, 33%, 74%, and 89% of the time, respectively, in the toric calculator group. These data show that the chance of a patient being in a lower postoperative RRA range increased when intraoperative aberrometry was used (P = .0130). Patients undergoing cataract extraction with toric IOL placement aided by intraoperative aberrometry were 2.4 times more likely to have less than 0.50 D of RRA compared to standard methods. Copyright 2015, SLACK Incorporated.

  15. A Review of Update Clinical Results of Carbon Ion Radiotherapy

    PubMed Central

    Tsujii, Hirohiko; Kamada, Tadashi

    2012-01-01

    Among various types of ion species, carbon ions are considered to have the most balanced, optimal properties in terms of possessing physically and biologically effective dose localization in the body. This is due to the fact that when compared with photon beams, carbon ion beams offer improved dose distribution, leading to the concentration of the sufficient dose within a target volume while minimizing the dose in the surrounding normal tissues. In addition, carbon ions, being heavier than protons, provide a higher biological effectiveness, which increases with depth, reaching the maximum at the end of the beam's range. This is practically an ideal property from the standpoint of cancer radiotherapy. Clinical studies have been carried out in the world to confirm the efficacy of carbon ions against a variety of tumors as well as to develop effective techniques for delivering an efficient dose to the tumor. Through clinical experiences of carbon ion radiotherapy at the National Institute of Radiological Sciences and Gesellschaft für Schwerionenforschung, a significant reduction in the overall treatment time with acceptable toxicities has been obtained in almost all types of tumors. This means that carbon ion radiotherapy has meanwhile achieved for itself a solid place in general practice. This review describes clinical results of carbon ion radiotherapy together with physical, biological and technological aspects of carbon ions. PMID:22798685

  16. Intraoperative laryngeal electromyography in children with vocal fold immobility: a simplified technique.

    PubMed

    Scott, Andrew R; Chong, Peter Siao Tick; Randolph, Gregory W; Hartnick, Christopher J

    2008-01-01

    The primary objective of this study was to determine whether a simplified technique for intraoperative laryngeal electromyography was feasible using standard nerve integrity monitoring electrodes and audiovisual digital recording equipment. Our secondary objective was to determine if laryngeal electromyography data provided any additional information that significantly influenced patient management. Between February 2006 and February 2007, 10 children referred to our institution with vocal fold immobility underwent intraoperative laryngeal electromyography of the thyroarytenoid muscles. A retrospective chart review of these 10 patients was performed after institutional review board approval. Standard nerve integrity monitoring electrodes can be used to perform intraoperative laryngeal electromyography of the thyroarytenoid muscles in children. In 5 of 10 cases reviewed, data from laryngeal electromyography recordings meaningfully influenced the care of children with vocal fold immobility and affected clinical decision-making, sometimes altering management strategies. In the remaining 5 children, data supported clinical impressions but did not alter treatment plans. Two children with idiopathic bilateral vocal fold paralysis initially presented with a lack of electrical activity on one or both sides but went on to develop motor unit action potentials that preceded recovery of motion in both vocal folds. Our findings suggest that standard nerve monitoring equipment can be used to perform intraoperative laryngeal electromyography and that electromyographic data can assist clinicians in the management of complex patients. Additionally, there may be a role for the use of serial intraoperative measurements in predicting recovery from vocal fold paralysis in the pediatric age group.

  17. A Case Report of Salvage Radiotherapy for a Patient with Recurrent Gastric Cancer and Multiple Comorbidities Using Real-time MRI-guided Adaptive Treatment System

    PubMed Central

    Jeon, Seung Hyuck; Chie, Eui Kyu

    2018-01-01

    The stomach is one of the most deforming organs caused by respiratory motions and daily variation by food intake. Applying radiotherapy has been quite a challenge due to the high risk of missing the target as well as radiation exposure to large volumes of normal tissue. However, real-time magnetic resonance (MR)-guided radiotherapy with adaptive planning could focus the high dose radiation to the target area while minimizing neighboring normal tissue exposure and compensate for not only daily but real-time variation. Here is a case report of a patient with recurrent gastric cancer and multiple co-morbidities, unsuitable for both resection and chemotherapy, who underwent MR guided adaptive radiotherapy. PMID:29900091

  18. Aortic curvature as a predictor of intraoperative type Ia endoleak.

    PubMed

    Schuurmann, Richte C L; Ouriel, Kenneth; Muhs, Bart E; Jordan, William D; Ouriel, Richard L; Boersen, Johannes T; de Vries, Jean-Paul P M

    2016-03-01

    Hostile infrarenal neck characteristics are associated with complications such as type Ia endoleak after endovascular aneurysm repair. Aortic neck angulation has been identified as one such characteristic, but its association with complications has not been uniform between studies. Neck angulation assumes triangular oversimplification of the aortic trajectory, which may explain conflicting findings. By contrast, aortic curvature is a measurement that includes the bending rate and tortuosity and may provide better predictive value for neck complications. Data were retrieved from the Heli-FX (Aptus Endosystems, Inc, Sunnyvale, Calif) Aortic Securement System Global Registry (ANCHOR). One cohort included patients who presented with intraoperative endoleak type Ia at the completion angiogram as the indication for EndoAnchors (Aptus Endosystems), and a second cohort comprised those without intraoperative or late type Ia endoleak (controls). The aortic trajectory was divided into six segments with potentially different influence on the stent graft performance: suprarenal, juxtarenal, and infrarenal aortic neck (-30 to -10 mm, -10 to 10 mm, and 10-30 mm from the lowest renal artery, respectively), the entire aortic neck, aneurysm sac, and terminal aorta (20 mm above the bifurcation to the bifurcation). Maximum and average curvature were automatically calculated over the six segments by proprietary custom software. Aortic curvature was compared with other standard neck characteristics, including neck length, neck diameter, maximum aneurysm sac diameter, neck thrombus and calcium thickness and circumference, suprarenal angulation, infrarenal angulation, and the neck tortuosity index. Independent risk factors for intraoperative type Ia endoleak were identified using backwards stepwise logistic regression. For the variables in the final regression model, suitable cutoff values in relation to the prediction of acute type Ia endoleak were defined with the area under the

  19. Registration of liver images to minimally invasive intraoperative surface and subsurface data

    NASA Astrophysics Data System (ADS)

    Wu, Yifei; Rucker, D. C.; Conley, Rebekah H.; Pheiffer, Thomas S.; Simpson, Amber L.; Geevarghese, Sunil K.; Miga, Michael I.

    2014-03-01

    Laparoscopic liver resection is increasingly being performed with results comparable to open cases while incurring less trauma and reducing recovery time. The tradeoff is increased difficulty due to limited visibility and restricted freedom of movement. Image-guided surgical navigation systems have the potential to help localize anatomical features to improve procedural safety and achieve better surgical resection outcome. Previous research has demonstrated that intraoperative surface data can be used to drive a finite element tissue mechanics organ model such that high resolution preoperative scans are registered and visualized in the context of the current surgical pose. In this paper we present an investigation of using sparse data as imposed by laparoscopic limitations to drive a registration model. Non-contact laparoscopicallyacquired surface swabbing and mock-ultrasound subsurface data were used within the context of a nonrigid registration methodology to align mock deformed intraoperative surface data to the corresponding preoperative liver model as derived from pre-operative image segmentations. The mock testing setup to validate the potential of this approach used a tissue-mimicking liver phantom with a realistic abdomen-port patient configuration. Experimental results demonstrates a range of target registration errors (TRE) on the order of 5mm were achieving using only surface swab data, while use of only subsurface data yielded errors on the order of 6mm. Registrations using a combination of both datasets achieved TRE on the order of 2.5mm and represent a sizeable improvement over either dataset alone.

  20. Intraoperative echocardiographic detection of regurgitant jets after valve replacement

    NASA Technical Reports Server (NTRS)

    Morehead, A. J.; Firstenberg, M. S.; Shiota, T.; Qin, J.; Armstrong, G.; Cosgrove, D. M. 3rd; Thomas, J. D.

    2000-01-01

    BACKGROUND: Paravalvular jets, documented by intraoperative transesophageal echocardiography, have prompted immediate valve explantation by others, yet the significance of these jets is unknown. METHODS: Twenty-seven patients had intraoperative transesophageal two-dimensional color Doppler echocardiography, performed to assess the number and area of regurgitant jets after valve replacement, before and after protamine. Patients were grouped by first time versus redo operation, valve position and type. RESULTS: Before protamine, 55 jets were identified (2.04+/-1.4 per patient) versus 29 jets after (1.07+/-1.2 per patient, p = 0.0002). Total jet area improved from 2.0+/-2.2 cm2 to 0.86+/-1.7 cm2 with protamine (p<0.0001). In all patients jet area decreased (average decrease, 70.7%+/-27.0%). First time and redo operations had similar improvements in jet number and area (both p>0.6). Furthermore, mitral and mechanical valves each had more jets and overall greater jet area when compared to aortic and tissue valves, respectively. CONCLUSIONS: Following valve replacement, multiple jets are detected by intraoperative transesophageal echocardiography. They are more common and larger in the mitral position and with mechanical valves. Improvement occurs with reversal of anticoagulation.

  1. Utility of Indocyanine Green Fluorescence Imaging for Intraoperative Localization in Reoperative Parathyroid Surgery.

    PubMed

    Sound, Sara; Okoh, Alexis; Yigitbas, Hakan; Yazici, Pinar; Berber, Eren

    2015-10-27

    Due to the variations in anatomic location, the identification of parathyroid glands may be challenging. Although there have been advances in preoperative imaging modalities, there is still a need for an accurate intraoperative guidance. Indocyanine green (ICG) is a new agent that has been used for intraoperative fluorescence imaging in a number of general surgical procedures. Its utility for parathyroid localization in humans has not been reported in the literature. We report 3 patients who underwent reoperative neck surgery for primary hyperparathyroidism. Using a video-assisted technique with intraoperative ICG fluorescence imaging, the parathyroid glands were recognized and removed successfully in all cases. Surrounding soft tissue structures remained nonfluorescent, and could be distinguished from the parathyroid glands. This report suggests a potential utility of ICG imaging in intraoperative localization of parathyroid glands in reoperative neck surgery. Future work is necessary to assess its benefit for first-time parathyroid surgery. © The Author(s) 2015.

  2. The Dutch Linguistic Intraoperative Protocol: a valid linguistic approach to awake brain surgery.

    PubMed

    De Witte, E; Satoer, D; Robert, E; Colle, H; Verheyen, S; Visch-Brink, E; Mariën, P

    2015-01-01

    Intraoperative direct electrical stimulation (DES) is increasingly used in patients operated on for tumours in eloquent areas. Although a positive impact of DES on postoperative linguistic outcome is generally advocated, information about the neurolinguistic methods applied in awake surgery is scarce. We developed for the first time a standardised Dutch linguistic test battery (measuring phonology, semantics, syntax) to reliably identify the critical language zones in detail. A normative study was carried out in a control group of 250 native Dutch-speaking healthy adults. In addition, the clinical application of the Dutch Linguistic Intraoperative Protocol (DuLIP) was demonstrated by means of anatomo-functional models and five case studies. A set of DuLIP tests was selected for each patient depending on the tumour location and degree of linguistic impairment. DuLIP is a valid test battery for pre-, intraoperative and postoperative language testing and facilitates intraoperative mapping of eloquent language regions that are variably located. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. What Do We Know About Intraoperative Teaching?: A Systematic Review.

    PubMed

    Timberlake, Matthew D; Mayo, Helen G; Scott, Lauren; Weis, Joshua; Gardner, Aimee K

    2017-08-01

    There is increasing attention on enhancing surgical trainee performance and competency. The purpose of this review is to identify characteristics and themes related to intraoperative teaching that will better inform interventions and assessment endeavors. A systematic search was carried out of the Ovid MEDLINE, Ovid MEDLINE InProcess, Ovid Embase, and the Cochrane Library databases to identify all studies that discussed teaching in the operating room for trainees at the resident and fellow level. Evidence for main outcome categories was evaluated with the Medical Education Research Study Quality Instrument (MERSQI). A total of 2101 records were identified. After screening by title, abstract, and full text, 34 studies were included. We categorized these articles into 3 groups on the basis of study methodology: perceptions, best practices, and interventions to enhance operative teaching. Overall strength of evidence for each type of study was as follows: perceptions (MERSQI: 7.5-10); best practices (6.5-11.5), and interventions (8-15). Although very few studies (n = 5) examined interventions for intraoperative teaching, these studies demonstrate the efficacy of techniques designed to enhance faculty teaching behaviors. Interventions have a positive impact on trainee ratings of their faculty intraoperative teaching performance. There is discordance between trainee perceptions of quantity and quality of teaching, compared with faculty perceptions of their own teaching behaviors. Frameworks and paradigms designed to provide best practices for intraoperative teaching agree that effective teaching spans 3 phases that take place before, during, and after cases.

  4. Quantitative correlational study of microbubble-enhanced ultrasound imaging and magnetic resonance imaging of glioma and early response to radiotherapy in a rat model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Chen; Lee, Dong-Hoon; Zhang, Kai

    Purpose: Radiotherapy remains a major treatment method for malignant tumors. Magnetic resonance imaging (MRI) is the standard modality for assessing glioma treatment response in the clinic. Compared to MRI, ultrasound imaging is low-cost and portable and can be used during intraoperative procedures. The purpose of this study was to quantitatively compare contrast-enhanced ultrasound (CEUS) imaging and MRI of irradiated gliomas in rats and to determine which quantitative ultrasound imaging parameters can be used for the assessment of early response to radiation in glioma. Methods: Thirteen nude rats with U87 glioma were used. A small thinned skull window preparation was performedmore » to facilitate ultrasound imaging and mimic intraoperative procedures. Both CEUS and MRI with structural, functional, and molecular imaging parameters were performed at preradiation and at 1 day and 4 days postradiation. Statistical analysis was performed to determine the correlations between MRI and CEUS parameters and the changes between pre- and postradiation imaging. Results: Area under the curve (AUC) in CEUS showed significant difference between preradiation and 4 days postradiation, along with four MRI parameters, T{sub 2}, apparent diffusion coefficient, cerebral blood flow, and amide proton transfer-weighted (APTw) (all p < 0.05). The APTw signal was correlated with three CEUS parameters, rise time (r = − 0.527, p < 0.05), time to peak (r = − 0.501, p < 0.05), and perfusion index (r = 458, p < 0.05). Cerebral blood flow was correlated with rise time (r = − 0.589, p < 0.01) and time to peak (r = − 0.543, p < 0.05). Conclusions: MRI can be used for the assessment of radiotherapy treatment response and CEUS with AUC as a new technique and can also be one of the assessment methods for early response to radiation in glioma.« less

  5. Quantitative correlational study of microbubble-enhanced ultrasound imaging and magnetic resonance imaging of glioma and early response to radiotherapy in a rat model.

    PubMed

    Yang, Chen; Lee, Dong-Hoon; Mangraviti, Antonella; Su, Lin; Zhang, Kai; Zhang, Yin; Zhang, Bin; Li, Wenxiao; Tyler, Betty; Wong, John; Wang, Ken Kang-Hsin; Velarde, Esteban; Zhou, Jinyuan; Ding, Kai

    2015-08-01

    Radiotherapy remains a major treatment method for malignant tumors. Magnetic resonance imaging (MRI) is the standard modality for assessing glioma treatment response in the clinic. Compared to MRI, ultrasound imaging is low-cost and portable and can be used during intraoperative procedures. The purpose of this study was to quantitatively compare contrast-enhanced ultrasound (CEUS) imaging and MRI of irradiated gliomas in rats and to determine which quantitative ultrasound imaging parameters can be used for the assessment of early response to radiation in glioma. Thirteen nude rats with U87 glioma were used. A small thinned skull window preparation was performed to facilitate ultrasound imaging and mimic intraoperative procedures. Both CEUS and MRI with structural, functional, and molecular imaging parameters were performed at preradiation and at 1 day and 4 days postradiation. Statistical analysis was performed to determine the correlations between MRI and CEUS parameters and the changes between pre- and postradiation imaging. Area under the curve (AUC) in CEUS showed significant difference between preradiation and 4 days postradiation, along with four MRI parameters, T2, apparent diffusion coefficient, cerebral blood flow, and amide proton transfer-weighted (APTw) (all p < 0.05). The APTw signal was correlated with three CEUS parameters, rise time (r = - 0.527, p < 0.05), time to peak (r = - 0.501, p < 0.05), and perfusion index (r = 458, p < 0.05). Cerebral blood flow was correlated with rise time (r = - 0.589, p < 0.01) and time to peak (r = - 0.543, p < 0.05). MRI can be used for the assessment of radiotherapy treatment response and CEUS with AUC as a new technique and can also be one of the assessment methods for early response to radiation in glioma.

  6. Intraoperative mechanical ventilation: state of the art.

    PubMed

    Ball, Lorenzo; Costantino, Federico; Orefice, Giulia; Chandrapatham, Karthikka; Pelosi, Paolo

    2017-10-01

    Mechanical ventilation is a cornerstone of the intraoperative management of the surgical patient and is still mandatory in several surgical procedures. In the last decades, research focused on preventing postoperative pulmonary complications (PPCs), both improving risk stratification through the use of predictive scores and protecting the lung adopting so-called protective ventilation strategies. The aim of this review was to give an up-to-date overview of the currently suggested intraoperative ventilation strategies, along with their pathophysiologic rationale, with a focus on challenging conditions, such as obesity, one-lung ventilation and cardiopulmonary bypass. While anesthesia and mechanical ventilation are becoming increasingly safe practices, the contribution to surgical mortality attributable to postoperative lung injury is not negligible: for these reasons, the prevention of PPCs, including the use of protective mechanical ventilation is mandatory. Mechanical ventilation should be optimized providing an adequate respiratory support while minimizing unwanted negative effects. Due to the high number of surgical procedures performed daily, the impact on patients' health and healthcare costs can be relevant, even when new strategies result in an apparently small improvement of outcome. A protective intraoperative ventilation should include a low tidal volume of 6-8 mL/kg of predicted body weight, plateau pressures ideally below 16 cmH2O, the lowest possible driving pressure, moderate-low PEEP levels except in obese patients, laparoscopy and long surgical procedures that might benefit of a slightly higher PEEP. The work of the anesthesiologist should start with a careful preoperative visit to assess the risk, and a close postoperative monitoring.

  7. Diffusion and perfusion weighted magnetic resonance imaging for tumor volume definition in radiotherapy of brain tumors.

    PubMed

    Guo, Lu; Wang, Gang; Feng, Yuanming; Yu, Tonggang; Guo, Yu; Bai, Xu; Ye, Zhaoxiang

    2016-09-21

    Accurate target volume delineation is crucial for the radiotherapy of tumors. Diffusion and perfusion magnetic resonance imaging (MRI) can provide functional information about brain tumors, and they are able to detect tumor volume and physiological changes beyond the lesions shown on conventional MRI. This review examines recent studies that utilized diffusion and perfusion MRI for tumor volume definition in radiotherapy of brain tumors, and it presents the opportunities and challenges in the integration of multimodal functional MRI into clinical practice. The results indicate that specialized and robust post-processing algorithms and tools are needed for the precise alignment of targets on the images, and comprehensive validations with more clinical data are important for the improvement of the correlation between histopathologic results and MRI parameter images.

  8. Is Adaptive Treatment Planning Required for Stereotactic Radiotherapy of Stage I Non-Small-Cell Lung Cancer?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haasbeek, Cornelis J.A.; Lagerwaard, Frank J.; Cuijpers, Johan P.

    2007-04-01

    Purpose: Changes in position or size of target volumes have been observed during radiotherapy for lung cancer. The need for adaptive treatment planning during stereotactic radiotherapy of Stage I tumors was retrospectively analyzed using repeat four-dimensional computed tomography (4DCT) scans. Methods and Materials: A planning study was performed for 60 tumors in 59 patients using 4DCT scans repeated after two or more treatment fractions. Planning target volumes (PTV) encompassed all tumor mobility, and dose distributions from the initial plan were projected onto PTVs derived from the repeat 4DCT. A dosimetric and volumetric analysis was performed. Results: The repeat 4DCT scansmore » were performed at a mean of 6.6 days (range, 2-12 days) after the first fraction of stereotactic radiotherapy. In 25% of cases the repeat PTV was larger, but the difference exceeded 1 mL in 5 patients only. The mean 3D displacement between the center of mass of both PTVs was 2.0 mm. The initial 80% prescription isodose ensured a mean coverage of 98% of repeat PTVs, and this isodose fully encompassed the repeat internal target volumes in all but 1 tumor. 'Inadequate' coverage in the latter was caused by a new area of atelectasis adjacent to the tumor on the repeat 4DCT. Conclusions: Limited 'time trends' were observed in PTVs generated by repeated uncoached 4DCT scans, and the dosimetric consequences proved to be minimal. Treatment based only on the initial PTV would not have resulted in major tumor underdosage, indicating that adaptive treatment planning is of limited value for fractionated stereotactic radiotherapy.« less

  9. Intraoperative Cochlear Implant Device Testing Utilizing an Automated Remote System: A Prospective Pilot Study.

    PubMed

    Lohmann, Amanda R; Carlson, Matthew L; Sladen, Douglas P

    2018-03-01

    Intraoperative cochlear implant device testing provides valuable information regarding device integrity, electrode position, and may assist with determining initial stimulation settings. Manual intraoperative device testing during cochlear implantation requires the time and expertise of a trained audiologist. The purpose of the current study is to investigate the feasibility of using automated remote intraoperative cochlear implant reverse telemetry testing as an alternative to standard testing. Prospective pilot study evaluating intraoperative remote automated impedance and Automatic Neural Response Telemetry (AutoNRT) testing in 34 consecutive cochlear implant surgeries using the Intraoperative Remote Assistant (Cochlear Nucleus CR120). In all cases, remote intraoperative device testing was performed by trained operating room staff. A comparison was made to the "gold standard" of manual testing by an experienced cochlear implant audiologist. Electrode position and absence of tip fold-over was confirmed using plain film x-ray. Automated remote reverse telemetry testing was successfully completed in all patients. Intraoperative x-ray demonstrated normal electrode position without tip fold-over. Average impedance values were significantly higher using standard testing versus CR120 remote testing (standard mean 10.7 kΩ, SD 1.2 vs. CR120 mean 7.5 kΩ, SD 0.7, p < 0.001). There was strong agreement between standard manual testing and remote automated testing with regard to the presence of open or short circuits along the array. There were, however, two cases in which standard testing identified an open circuit, when CR120 testing showed the circuit to be closed. Neural responses were successfully obtained in all patients using both systems. There was no difference in basal electrode responses (standard mean 195.0 μV, SD 14.10 vs. CR120 194.5 μV, SD 14.23; p = 0.7814); however, more favorable (lower μV amplitude) results were obtained with the remote

  10. Difference in target definition using three different methods to include respiratory motion in radiotherapy of lung cancer.

    PubMed

    Sloth Møller, Ditte; Knap, Marianne Marquard; Nyeng, Tine Bisballe; Khalil, Azza Ahmed; Holt, Marianne Ingerslev; Kandi, Maria; Hoffmann, Lone

    2017-11-01

    Minimizing the planning target volume (PTV) while ensuring sufficient target coverage during the entire respiratory cycle is essential for free-breathing radiotherapy of lung cancer. Different methods are used to incorporate the respiratory motion into the PTV. Fifteen patients were analyzed. Respiration can be included in the target delineation process creating a respiratory GTV, denoted iGTV. Alternatively, the respiratory amplitude (A) can be measured based on the 4D-CT and A can be incorporated in the margin expansion. The GTV expanded by A yielded GTV + resp, which was compared to iGTV in terms of overlap. Three methods for PTV generation were compared. PTV del (delineated iGTV expanded to CTV plus PTV margin), PTV σ (GTV expanded to CTV and A was included as a random uncertainty in the CTV to PTV margin) and PTV ∑ (GTV expanded to CTV, succeeded by CTV linear expansion by A to CTV + resp, which was finally expanded to PTV ∑ ). Deformation of tumor and lymph nodes during respiration resulted in volume changes between the respiratory phases. The overlap between iGTV and GTV + resp showed that on average 7% of iGTV was outside the GTV + resp implying that GTV + resp did not capture the tumor during the full deformable respiration cycle. A comparison of the PTV volumes showed that PTV σ was smallest and PTV Σ largest for all patients. PTV σ was in mean 14% (31 cm 3 ) smaller than PTV del , while PTV del was 7% (20 cm 3 ) smaller than PTV Σ . PTV σ yields the smallest volumes but does not ensure coverage of tumor during the full respiratory motion due to tumor deformation. Incorporating the respiratory motion in the delineation (PTV del ) takes into account the entire respiratory cycle including deformation, but at the cost, however, of larger treatment volumes. PTV Σ should not be used, since it incorporates the disadvantages of both PTV del and PTV σ .

  11. Microscope Integrated Intraoperative Spectral Domain Optical Coherence Tomography for Cataract Surgery: Uses and Applications.

    PubMed

    Das, Sudeep; Kummelil, Mathew Kurian; Kharbanda, Varun; Arora, Vishal; Nagappa, Somshekar; Shetty, Rohit; Shetty, Bhujang K

    2016-05-01

    To demonstrate the uses and applications of a microscope integrated intraoperative Optical Coherence Tomography in Micro Incision Cataract Surgery (MICS) and Femtosecond Laser Assisted Cataract Surgery (FLACS). Intraoperative real time imaging using the RESCAN™ 700 (Carl Zeiss Meditec, Oberkochen, Germany) was done for patients undergoing MICS as well as FLACS. The OCT videos were reviewed at each step of the procedure and the findings were noted and analyzed. Microscope Integrated Intraoperative Optical Coherence Tomography was found to be beneficial during all the critical steps of cataract surgery. We were able to qualitatively assess wound morphology in clear corneal incisions, in terms of subclinical Descemet's detachments, tears in the inner or outer wound lips, wound gaping at the end of surgery and in identifying the adequacy of stromal hydration, for both FLACS as well as MICS. It also enabled us to segregate true posterior polar cataracts from suspected cases intraoperatively. Deciding the adequate depth of trenching was made simpler with direct visualization. The final position of the intraocular lens in the capsular bag and the lack of bioadhesivity of hydrophobic acrylic lenses were also observed. Even though Microscope Integrated Intraoperative Optical Coherence Tomography is in its early stages for its application in cataract surgery, this initial assessment does show a very promising role for this technology in the future for cataract surgery both in intraoperative decision making as well as for training purposes.

  12. Improved surgical procedure using intraoperative navigation for the implantation of the SPG microstimulator in patients with chronic cluster headache.

    PubMed

    Kohlmeier, Carsten; Behrens, Peter; Böger, Andreas; Ramachandran, Brinda; Caparso, Anthony; Schulze, Dirk; Stude, Philipp; Heiland, Max; Assaf, Alexandre T

    2017-12-01

    The ATI SPG microstimulator is designed to be fixed on the posterior maxilla, with the integrated lead extending into the pterygopalatine fossa to electrically stimulate the sphenopalatine ganglion (SPG) as a treatment for cluster headache. Preoperative surgical planning to ensure the placement of the microstimulator in close proximity (within 5 mm) to the SPG is critical for treatment efficacy. The aim of this study was to improve the surgical procedure by navigating the initial dissection prior to implantation using a passive optical navigation system and to match the post-operative CBCT images with the preoperative treatment plan to verify the accuracy of the intraoperative placement of the microstimulator. Custom methods and software were used that result in a 3D rotatable digitally reconstructed fluoroscopic image illustrating the patient-specific placement with the ATI SPG microstimulator. Those software tools were preoperatively integrated with the planning software of the navigation system to be used intraoperatively for navigated placement. Intraoperatively, the SPG microstimulator was implanted by completing the initial dissection with CT navigation, while the final position of the stimulator was verified by 3D CBCT. Those reconstructed images were then immediately matched with the preoperative CT scans with the digitally inserted SPG microstimulator. This method allowed for visual comparison of both CT scans and verified correct positioning of the SPG microstimulator. Twenty-four surgeries were performed using this new method of CT navigated assistance during SPG microstimulator implantation. Those results were compared to results of 21 patients previously implanted without the assistance of CT navigation. Using CT navigation during the initial dissection, an average distance reduction of 1.2 mm between the target point and electrode tip of the SPG microstimulator was achieved. Using the navigation software for navigated implantation and matching the

  13. Intraoperative computed tomography guided neuronavigation: concepts, efficiency, and work flow.

    PubMed

    Matula, C; Rössler, K; Reddy, M; Schindler, E; Koos, W T

    1998-01-01

    Image-guided surgery is currently considered to be of undisputed value in microsurgical and endoscopical neurosurgery, but one of its major drawbacks is the degradation of accuracy during frameless stereotactic neuronavigation due to brain and/or lesion shift. A computed tomography (CT) scanner system (Philips Tomoscan M) developed for the operating room was connected to a pointer device navigation system for image-guided surgery (Philips EasyGuide system) in order to provide an integrated solution to this problem, and the advantages of this combination were evaluated in 20 cases (15 microsurgical and 5 endoscopic). The integration of the scanner into the operating room setup was successful in all procedures. The patients were positioned on a specially developed scanner table, which permitted movement to a scanning position then back to the operating position at any time during surgery. Contrast-enhanced preoperative CCTs performed following positioning and draping were of high quality in all cases, because a radiolucent head fixation technique was used. The accuracy achieved with this combination was significantly better (1.6:1.22.2). The overall concept is one of working in a closed system where everything is done in the same room, and the efficiency of this is clearly proven in different ways. The most important fact is the time saved in the overall treatment process (about 55 h for one operating room over a 6-month period). The combination of an intraoperative CCT scanner with the pointer device neuronavigation system permits not only the intraoperative control of resection of brain tumors, but also (in about 20% of cases) the identification of otherwise invisible residual tumor tissue by intraoperative update of the neuronavigation data set. Additionally, an image update solves the problem of intraoperative brain and/or tumor shifts during image-guided resection. Having the option of making an intraoperative quality check at any time leads to significantly

  14. A new brain positron emission tomography scanner with semiconductor detectors for target volume delineation and radiotherapy treatment planning in patients with nasopharyngeal carcinoma.

    PubMed

    Katoh, Norio; Yasuda, Koichi; Shiga, Tohru; Hasegawa, Masakazu; Onimaru, Rikiya; Shimizu, Shinichi; Bengua, Gerard; Ishikawa, Masayori; Tamaki, Nagara; Shirato, Hiroki

    2012-03-15

    We compared two treatment planning methods for stereotactic boost for treating nasopharyngeal carcinoma (NPC): the use of conventional whole-body bismuth germanate (BGO) scintillator positron emission tomography (PET(CONV)WB) versus the new brain (BR) PET system using semiconductor detectors (PET(NEW)BR). Twelve patients with NPC were enrolled in this study. [(18)F]Fluorodeoxyglucose-PET images were acquired using both the PET(NEW)BR and the PET(CONV)WB system on the same day. Computed tomography (CT) and two PET data sets were transferred to a treatment planning system, and the PET(CONV)WB and PET(NEW)BR images were coregistered with the same set of CT images. Window width and level values for all PET images were fixed at 3000 and 300, respectively. The gross tumor volume (GTV) was visually delineated on PET images by using either PET(CONV)WB (GTV(CONV)) images or PET(NEW)BR (GTV(NEW)) images. Assuming a stereotactic radiotherapy boost of 7 ports, the prescribed dose delivered to 95% of the planning target volume (PTV) was set to 2000 cGy in 4 fractions. The average absolute volume (±standard deviation [SD]) of GTV(NEW) was 15.7 ml (±9.9) ml, and that of GTV(CONV) was 34.0 (±20.5) ml. The average GTV(NEW) was significantly smaller than that of GTV(CONV) (p = 0.0006). There was no statistically significant difference between the maximum dose (p = 0.0585) and the mean dose (p = 0.2748) of PTV. The radiotherapy treatment plan based on the new gross tumor volume (PLAN(NEW)) significantly reduced maximum doses to the cerebrum and cerebellum (p = 0.0418) and to brain stem (p = 0.0041). Results of the present study suggest that the new brain PET system using semiconductor detectors can provide more accurate tumor delineation than the conventional whole-body BGO PET system and may be an important tool for functional and molecular radiotherapy treatment planning. Copyright © 2012 Elsevier Inc. All rights reserved.

  15. Fluorescein-guided intraoperative endoscopy in patients with hereditary hemorrhagic telangiectasia: first impressions.

    PubMed

    Pagella, Fabio; Pusateri, Alessandro; Zaccari, Dario; Bongetta, Daniele; Zoia, Cesare; Spinozzi, Giuseppe; Olivieri, Carla; Matti, Elina

    2017-03-01

    Hereditary hemorrhagic telangiectasia (HHT) is a rare genetic disease that results in mucocutaneous telangiectasias and arteriovenous visceral malformations. Nasal telangiectasias lead to recurrent epistaxis, which affects up to 96% of patients. Different morphologic classifications and methods of visualization of nasal lesions have been described in the literature. We developed a new method of intraoperative endoscopy based on the intravenous administration of fluorescein. Preliminary data of this technique are reported. After the intravenous administration of sodium fluorescein, an intraoperative fluorescein-guided endoscopy was carried out using photographic customized yellow filters on top of a 0-degree, 4-mm endoscope. In 2015, 65 HHT patients underwent surgery for their epistaxis in our institution, and in 7 patients (3 males, 4 females; mean age, 54 years) an intraoperative fluorescein-guided intraoperative nasal endoscopy was performed. No adverse events or complications were observed. First impressions regarding the usage of this technique in HHT patients seem to be promising and positive in terms of efficacy and safety. However, further studies with larger cohorts of patients should be performed in order to better investigate the use of this method for diagnostic and surgical purposes in HHT. © 2016 ARS-AAOA, LLC.

  16. The Dosimetric Consequences of Intensity Modulated Radiotherapy for Cervix Cancer: The Impact of Organ Motion, Deformation and Tumour Regression

    NASA Astrophysics Data System (ADS)

    Lim, Karen Siah Huey

    Hypothesis: In intensity modulated radiotherapy (IMRT) for cervix cancer, the dose received by the tumour target and surrounding normal tissues is significantly different to that indicated by a single static plan. Rationale: The optimal use of IMRT in cervix cancer requires a greater attention to clinical target volume (CTV) definition and tumour & normal organ motion to assure maximum tumour control with the fewest side effects. Research Aims: 1) Generate consensus CTV contouring guidelines for cervix cancer; 2) Evaluate intra-pelvic tumour and organ dynamics during radiotherapy; 3) Analyze the dose consequences of intra-pelvic organ dynamics on different radiotherapy strategies. Results: Consensus CTV definitions were generated using experts-in-the-field. Substantial changes in tumour volume and organ motion, resulted in significant reductions in accumulated dose to tumour targets and variability in accumulated dose to surrounding normal tissues. Significance: Formalized CTV definitions for cervix cancer is important in ensuring consistent standards of practice. Complex and unpredictable tumour and organ dynamics mandates daily soft-tissue image guidance if IMRT is used. To maximize the benefits of IMRT for cervix cancer, a strategy of adaptation is necessary.

  17. Effect of intraoperative dobutamine on splanchnic tissue perfusion and outcome after Whipple surgery.

    PubMed

    Reyad, Amal Rashad; Elkharboutly, Walaa; Wahba, Ashraf; Elmorshedi, Mohamed; Hasaneen, Nadia A

    2013-08-01

    Splanchnic hypoperfusion during abdominal surgery contributes to postoperative gut sepsis and mortality. Dobutamine is an inotrope with vasodilator properties that improve hepatosplanchnic perfusion. The aim of this study was to examine the effect of intraoperative dobutamine infusion during Whipple surgery on splanchnic perfusion, hemodynamic, and overall postoperative outcome. Sixty patients were randomly allocated to receive intraoperatively (3 μg/kg per minute or 5 μg/kg per minute) doses of dobutamine or saline. Baseline measurements included hemodynamic parameters, gastric tonometric parameters, and arterial and mixed venous gases. These patients had a follow-up for development for in-hospital morbidity and mortality. Intraoperative use of dobutamine increased oxygen-derived parameters as evidenced by increased mixed venous oxygen saturation. Tonometered gastric mucosal pH, a surrogate for splanchnic perfusion, increased in patients who received intraoperative dobutamine. Patients in the dobutamine groups demonstrated significant higher heart rates, premature ventricular contraction arrhythmias, and electrocardiographic signs of ischemia. Mean arterial blood pressure demonstrated no significant difference among groups. The overall incidence of postoperative complications was higher in control group 70 % vs 20% to 40% in dobutamine groups. Intraoperative use of dobutamine improved global oxygen delivery, splanchnic perfusion, and postoperative outcome after Whipple surgery. These findings may be of clinical importance when the therapeutic goal is to improve gut perfusion. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Intraoperative magnetic resonance imaging with the magnetom open scanner: concepts, neurosurgical indications, and procedures: a preliminary report.

    PubMed

    Steinmeier, R; Fahlbusch, R; Ganslandt, O; Nimsky, C; Buchfelder, M; Kaus, M; Heigl, T; Lenz, G; Kuth, R; Huk, W

    1998-10-01

    Intraoperative magnetic resonance imaging (MRI) is now available with the General Electric MRI system for dedicated intraoperative use. Alternatively, non-dedicated MRI systems require fewer specific adaptations of instrumentation and surgical techniques. In this report, clinical experiences with such a system are presented. All patients were surgically treated in a "twin operating theater," consisting of a conventional operating theater with complete neuronavigation equipment (StealthStation and MKM), which allowed surgery with magnetically incompatible instruments, conventional instrumentation and operating microscope, and a radiofrequency-shielded operating room designed for use with an intraoperative MRI scanner (Magnetom Open; Siemens AG, Erlangen, Germany). The Magnetom Open is a 0.2-T MRI scanner with a resistive magnet and specific adaptations that are necessary to integrate the scanner into the surgical environment. The operating theaters lie close together, and patients can be intraoperatively transported from one room to the other. This retrospective analysis includes 55 patients with cerebral lesions, all of whom were surgically treated between March 1996 and September 1997. Thirty-one patients with supratentorial tumors were surgically treated (with navigational guidance) in the conventional operating room, with intraoperative MRI for resection control. For 5 of these 31 patients, intraoperative resection control revealed significant tumor remnants, which led to further tumor resection guided by the information provided by intraoperative MRI. Intraoperative MRI resection control was performed in 18 transsphenoidal operations. In cases with suspected tumor remnants, the surgeon reexplored the sellar region; additional tumor tissue was removed in three of five cases. Follow-up scans were obtained for all patients 1 week and 2 to 3 months after surgery. For 14 of the 18 patients, the images obtained intraoperatively were comparable to those obtained after

  19. Intraoperative culture positive allograft bone and subsequent postoperative infections: a retrospective review.

    PubMed

    Sims, Laura; Kulyk, Paul; Woo, Allan

    2017-04-01

    Obtaining intraoperative cultures of allograft bone just before use in orthopedic procedures is standard practice in many centres; however, the association between positive cultures and subsequent surgical infections is unknown. Our study had 3 goals: to determine the prevalence of positive intraoperative allograft culture and subsequent infection; to determine if, in cases of subsequent infection, organisms isolated at reoperation were the same as those cultured from the allograft at the time of the index procedure; and to assess the costs associated with performing intraoperative allograft cultures. In this retrospective case series, we obtained data on patients receiving allograft bone between 2009 and 2012. Patients receiving allograft with positive cultures were reviewed to identify cases of significant infection. Organisms isolated at reoperation were compared with the allograft culture taken at the time of implantation, and we performed a cost assessment. Of the 996 allograft bone grafts used, 43 (4.3%) had positive intraoperative cultures and significant postoperative infections developed in 2, requiring reoperation. Antibiotics based on culture results were prescribed in 24% of cases. Organisms cultured at the time of reoperation differed from those isolated initially. The cost of performing 996 allograft cultures was $169 320. This series suggests that rates of positive intraoperative bone allograft culture are low, and subsequent infection is rare. In cases of postoperative infection, primary allograft culture and secondary tissue cultures isolated different organisms. Costs associated with performing cultures are high. Eliminating initial culture testing could save $42 500 per year in our health region.

  20. Intraoperative culture positive allograft bone and subsequent postoperative infections: a retrospective review

    PubMed Central

    Sims, Laura; Kulyk, Paul; Woo, Allan

    2017-01-01

    Background Obtaining intraoperative cultures of allograft bone just before use in orthopedic procedures is standard practice in many centres; however, the association between positive cultures and subsequent surgical infections is unknown. Our study had 3 goals: to determine the prevalence of positive intraoperative allograft culture and subsequent infection; to determine if, in cases of subsequent infection, organisms isolated at reoperation were the same as those cultured from the allograft at the time of the index procedure; and to assess the costs associated with performing intraoperative allograft cultures. Methods In this retrospective case series, we obtained data on patients receiving allograft bone between 2009 and 2012. Patients receiving allograft with positive cultures were reviewed to identify cases of significant infection. Organisms isolated at reoperation were compared with the allograft culture taken at the time of implantation, and we performed a cost assessment. Results Of the 996 allograft bone grafts used, 43 (4.3%) had positive intraoperative cultures and significant postoperative infections developed in 2, requiring reoperation. Antibiotics based on culture results were prescribed in 24% of cases. Organisms cultured at the time of reoperation differed from those isolated initially. The cost of performing 996 allograft cultures was $169 320. Conclusion This series suggests that rates of positive intraoperative bone allograft culture are low, and subsequent infection is rare. In cases of postoperative infection, primary allograft culture and secondary tissue cultures isolated different organisms. Costs associated with performing cultures are high. Eliminating initial culture testing could save $42 500 per year in our health region. PMID:28234217

  1. [Technique of complex mammary irradiation: Mono-isocentric 3D conformational radiotherapy and helical tomotherapy].

    PubMed

    Vandendorpe, B; Guilbert, P; Champagne, C; Antoni, T; Nguyen, T D; Gaillot-Petit, N; Servagi Vernat, S

    2017-12-01

    To evaluate the dosimetric contribution of helical tomotherapy for breast cancers compared with conformal radiotherapy in mono-isocentric technique. For 23 patients, the dosimetric results in mono-isocentric 3D conformational radiotherapy did not satisfy the constraints either of target volumes nor organs at risk. A prospective dosimetric comparison between mono-isocentric 3D conformational radiotherapy and helical tomotherapy was therefore carried out. The use of helical tomotherapy showed a benefit in these 23 patients, with either an improvement in the conformity index or homogeneity, but with an increase in low doses. Of the 23 patients, two had pectus excavatum, five had past thoracic irradiation and two required bilateral irradiation. The other 14 patients had a combination of morphology and/or indication of lymph node irradiation. For these patients, helical tomotherapy was therefore preferred to mono-isocentric 3D conformational radiotherapy. Tomotherapy appears to provide better homogeneity and tumour coverage. This technique of irradiation may be justified in the case of morphological situations such as pectus exavatum and in complex clinical situations. In other cases, conformal radiotherapy in mono-isocentric technique remains to be favoured. Copyright © 2017 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  2. Radiotherapy Dose-Volume Effects on Salivary Gland Function

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deasy, Joseph O., E-mail: jdeasy@radonc.wustl.ed; Moiseenko, Vitali; Marks, Lawrence

    2010-03-01

    Publications relating parotid dose-volume characteristics to radiotherapy-induced salivary toxicity were reviewed. Late salivary dysfunction has been correlated to the mean parotid gland dose, with recovery occurring with time. Severe xerostomia (defined as long-term salivary function of <25% of baseline) is usually avoided if at least one parotid gland is spared to a mean dose of less than {approx}20 Gy or if both glands are spared to less than {approx}25 Gy (mean dose). For complex, partial-volume RT patterns (e.g., intensity-modulated radiotherapy), each parotid mean dose should be kept as low as possible, consistent with the desired clinical target volume coverage. Amore » lower parotid mean dose usually results in better function. Submandibular gland sparing also significantly decreases the risk of xerostomia. The currently available predictive models are imprecise, and additional study is required to identify more accurate models of xerostomia risk.« less

  3. Intraoperative Neurophysiological Monitoring in Spine Surgery: A Significant Tool for Neuronal Protection and Functional Restoration.

    PubMed

    Scibilia, Antonino; Raffa, Giovanni; Rizzo, Vincenzo; Quartarone, Angelo; Visocchi, Massimiliano; Germanò, Antonino; Tomasello, Francesco

    2017-01-01

    Although there is recent evidence for the role of intraoperative neurophysiological monitoring (IONM) in spine surgery, there are no uniform opinions on the optimal combination of the different tools. At our institution, multimodal IONM (mIONM) approach in spine surgery involves the evaluation of somatosensory evoked potentials (SEPs) and motor evoked potentials (MEPs) with electrical transcranial stimulation, including the use of a multipulse technique with multiple myomeric registration of responses from limbs, and a single-pulse technique with D-wave registration through epi- and intradural recording, and free running and evoked electromyography (frEMG and eEMG) with bilateral recording from segmental target muscles. We analyzed the impact of the mIONM on the preservation of neuronal structures and on functional restoration in a prospective series of patients who underwent spine surgery. We observed an improvement of neurological status in 50 % of the patients. The D-wave registration was the most useful intraoperative tool, especially when MEP and SEP responses were absent or poorly recordable. Our preliminary data confirm that mIONM plays a fundamental role in the identification and functional preservation of the spinal cord and nerve roots. It is highly sensitive and specific for detecting and avoiding neurological injury during spine surgery and represents a helpful tool for achieving optimal postoperative functional outcome.

  4. Toxicity and dosimetric analysis of non-small cell lung cancer patients undergoing radiotherapy with 4DCT and image-guided intensity modulated radiotherapy: a regional centre's experience.

    PubMed

    Livingston, Gareth C; Last, Andrew J; Shakespeare, Thomas P; Dwyer, Patrick M; Westhuyzen, Justin; McKay, Michael J; Connors, Lisa; Leader, Stephanie; Greenham, Stuart

    2016-09-01

    For patients receiving radiotherapy for locally advance non-small cell lung cancer (NSCLC), the probability of experiencing severe radiation pneumonitis (RP) appears to rise with an increase in radiation received by the lungs. Intensity modulated radiotherapy (IMRT) provides the ability to reduce planned doses to healthy organs at risk (OAR) and can potentially reduce treatment-related side effects. This study reports toxicity outcomes and provides a dosimetric comparison with three-dimensional conformal radiotherapy (3DCRT). Thirty curative NSCLC patients received radiotherapy using four-dimensional computed tomography and five-field IMRT. All were assessed for early and late toxicity using common terminology criteria for adverse events. All plans were subsequently re-planned using 3DCRT to the same standard as the clinical plans. Dosimetric parameters for lungs, oesophagus, heart and conformity were recorded for comparison between the two techniques. IMRT plans achieved improved high-dose conformity and reduced OAR doses including lung volumes irradiated to 5-20 Gy. One case each of oesophagitis and erythema (3%) were the only Grade 3 toxicities. Rates of Grade 2 oesophagitis were 40%. No cases of Grade 3 RP were recorded and Grade 2 RP rates were as low as 3%. IMRT provides a dosimetric benefit when compared to 3DCRT. While the clinical benefit appears to increase with increasing target size and increasing complexity, IMRT appears preferential to 3DCRT in the treatment of NSCLC.

  5. Intra-operative visualization of brain tumors with 5-aminolevulinic acid-induced fluorescence.

    PubMed

    Widhalm, Georg

    2014-01-01

    Precise histopathological diagnosis of brain tumors is essential for the correct patient management. Furthermore, complete resection of brain tumors is associated with an improved patient prognosis. However, histopathological undergrading and incomplete tumor removal are not uncommon, especially due to insufficient intra-operative visualization of brain tumor tissue. The fluorescent dye 5-aminolevulinic acid (5-ALA) is currently applied for fluorescence-guided resections of high-grade gliomas. The value of 5-ALA-induced protoporphyrin (PpIX) fluorescence for intra-operative visualization of other tumors than high-grade gliomas remains unclear. Within the frame of this thesis, we found a significantly higher rate of complete resections of our high-grade gliomas as compared to control cases by using the newly established 5-ALA fluorescence technology at our department. Additionally, we showed that MRI spectroscopy-based chemical shift imaging (CSI) is capable to identify intratumoral high-grade glioma areas (= anaplastic foci) during navigation guided resections to avoid histopathological undergrading. However, the accuracy of navigation systems with integrated pre-operative imaging data such as CSI declines during resections due to intra-operative brainshift. In two further studies, we found that 5-ALA induced PpIX fluorescence is capable as a novel intra-operative marker to detect anaplastic foci within initially suspected low-grade gliomas independent of brainshift. Finally, we showed that the application of 5-ALA is also of relevance in needle biopsies for intra-operative identification of representative brain tumor tissue. These data indicate that 5-ALA is not only of major importance for resection of high-grade gliomas, but also for intra-operative visualization of anaplastic foci as well as representative brain tumor tissue in needle biopsies unaffected by brainshift. Consequently, this new technique might become a novel standard in brain tumor surgery that

  6. Intraoperative monitoring of blood perfusion in port wine stains by laser Doppler imaging during vascular targeted photodynamic therapy: A preliminary study.

    PubMed

    Chen, Defu; Ren, Jie; Wang, Ying; Li, Buhong; Gu, Ying

    2016-06-01

    The objective of this study was to monitor blood perfusion dynamics of port wine stains (PWS) during vascular targeted photodynamic therapy (V-PDT) with laser Doppler imaging (LDI). The PWS lesions of 30 facial PWS patients received V-PDT, while the normal skins on the forearm of 5 healthy subjects were treated as light-only controls for comparison. Furthermore, two different PWS lesions in the same individual from each of 3 PWS patients successively received laser irradiation only and V-PDT, respectively. LDI was used to monitor intraoperative blood perfusion dynamics. During V-PDT, the blood perfusion (278±96 PU) in PWS lesions for 31 of 33 PWS patients significantly increased after the initiation of V-PDT treatment, then reached a peak (638±105 PU) within 10min, followed by a slow decrease to a relatively lower level (515±100 PU). Furthermore, the time for reaching peak and the subsequent magnitude of decrease in blood perfusion varied with different patients. For light-only controls, an initial perfusion peak at 3min followed by a nadir and a secondary increase were found not only in normal skin, but also in PWS lesions. The preliminary results showed that the LDI permits non-invasive monitoring blood perfusion changes of PWS lesions during V-PDT. There was a clear trend in blood perfusion responses during V-PDT and laser irradiation. The blood perfusion changes during treatment were due to V-PDT effects as well as local temperature increase induced by laser irradiation. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Radiotherapy.

    PubMed

    Krause, Sonja; Debus, Jürgen; Neuhof, Dirk

    2011-01-01

    Solitary plasmocytoma occurring in bone (solitary plasmocytoma of the bone, SBP) or in soft tissue (extramedullary plasmocytoma, EP) can be treated effectively and with little toxicity by local radiotherapy. Ten-year local control rates of up to 90% can be achieved. Patients with multiple myeloma often suffer from symptoms such as pain or neurological impairments that are amenable to palliative radiotherapy. In a palliative setting, short treatment schedules and lower radiation doses are used to reduce toxicity and duration of hospitalization. In future, low-dose total body irradiation (TBI) may play a role in a potentially curative regimen with nonmyeloablative conditioning followed by allogenic peripheral blood stem cell transplantation.

  8. Registration-free laparoscope augmentation for intra-operative liver resection planning

    NASA Astrophysics Data System (ADS)

    Feuerstein, Marco; Mussack, Thomas; Heining, Sandro M.; Navab, Nassir

    2007-03-01

    In recent years, an increasing number of liver tumor indications were treated by minimally invasive laparoscopic resection. Besides the restricted view, a major issue in laparoscopic liver resection is the enhanced visualization of (hidden) vessels, which supply the tumorous liver segment and thus need to be divided prior to the resection. To navigate the surgeon to these vessels, pre-operative abdominal imaging data can hardly be used due to intraoperative organ deformations mainly caused by appliance of carbon dioxide pneumoperitoneum and respiratory motion. While regular respiratory motion can be gated and synchronized intra-operatively, motion caused by pneumoperitoneum is individual for every patient and difficult to estimate. Therefore, we propose to use an optically tracked mobile C-arm providing cone-beam CT imaging capability intraoperatively. The C-arm is able to visualize soft tissue by means of its new flat panel detector and is calibrated offline to relate its current position and orientation to the coordinate system of a reconstructed volume. Also the laparoscope is optically tracked and calibrated offline, so both laparoscope and C-arm are registered in the same tracking coordinate system. Intra-operatively, after patient positioning, port placement, and carbon dioxide insufflation, the liver vessels are contrasted and scanned during patient exhalation. Immediately, a three-dimensional volume is reconstructed. Without any further need for patient registration, the volume can be directly augmented on the live laparoscope video, visualizing the contrasted vessels. This augmentation provides the surgeon with advanced visual aid for the localization of veins, arteries, and bile ducts to be divided or sealed.

  9. Fusion of intraoperative force sensoring, surface reconstruction and biomechanical modeling

    NASA Astrophysics Data System (ADS)

    Röhl, S.; Bodenstedt, S.; Küderle, C.; Suwelack, S.; Kenngott, H.; Müller-Stich, B. P.; Dillmann, R.; Speidel, S.

    2012-02-01

    Minimally invasive surgery is medically complex and can heavily benefit from computer assistance. One way to help the surgeon is to integrate preoperative planning data into the surgical workflow. This information can be represented as a customized preoperative model of the surgical site. To use it intraoperatively, it has to be updated during the intervention due to the constantly changing environment. Hence, intraoperative sensor data has to be acquired and registered with the preoperative model. Haptic information which could complement the visual sensor data is still not established. In addition, biomechanical modeling of the surgical site can help in reflecting the changes which cannot be captured by intraoperative sensors. We present a setting where a force sensor is integrated into a laparoscopic instrument. In a test scenario using a silicone liver phantom, we register the measured forces with a reconstructed surface model from stereo endoscopic images and a finite element model. The endoscope, the instrument and the liver phantom are tracked with a Polaris optical tracking system. By fusing this information, we can transfer the deformation onto the finite element model. The purpose of this setting is to demonstrate the principles needed and the methods developed for intraoperative sensor data fusion. One emphasis lies on the calibration of the force sensor with the instrument and first experiments with soft tissue. We also present our solution and first results concerning the integration of the force sensor as well as accuracy to the fusion of force measurements, surface reconstruction and biomechanical modeling.

  10. The Association of Targeted Cell Salvage Blood Transfusion During Cesarean Delivery With Allogeneic Packed Red Blood Cell Transfusions in a Maternity Hospital in China.

    PubMed

    Yan, Haiya; Hu, Ling-Qun; Wu, Yun; Fan, Qihui; Wong, Cynthia A; McCarthy, Robert J

    2018-03-01

    Autologous transfusion of intraoperative cell salvage blood may be a potential method to decrease the need for allogeneic packed red blood cell transfusions after cesarean delivery, although there are limited data on the benefits of this method. This study evaluated the implementation of targeted intraoperative cell salvage during cesarean delivery in women at increased risk for hemorrhage at the Women's and Children's Hospital in Ningbo, China. All women who underwent cesarean delivery >28 weeks of gestation were included in the study. The period before intraoperative cell collection (October 1, 2010, to August 31, 2012, n = 11,322) was compared with the postimplementation period (September 1, 2012, to June 30, 2015, n = 17,456) using an interrupted time series analysis. In the postimplementation period, women suspected to be at increased risk of the need for a blood transfusion (1604, 9.2%) underwent intraoperative cell salvage collection. The primary outcomes were the monthly rate of allogeneic packed red blood cell use and the incidence of clinical manifestation of acute blood transfusion reactions. The mean (standard deviation) estimated monthly allogeneic packed blood cell transfusion rate at the end of the 57-month study was 2.2% ± 0.7% with the implementation compared with 2.7% ± 0.9% without, difference -0.5%, 95% CI, -1.4% to 0.3%; P = .22. The mean number of allogeneic units transfused per patient was 4.1 ± 0.4 units with implementation and 3.9 ± 0.9 units without, difference 0.2, 95% CI, -1.7 to 1.1 units; P = .69. Intraoperative cell salvage blood was reinfused in 757 (47%) and wasted in 847 (53%) cases. The monthly intraoperative allogeneic packed red blood cells use rate was lower after implementation (difference -0.7%, 95% CI, -0.1% to -1.4%; P = .03); however, the monthly postpartum allogeneic packed red blood cell use rate was unchanged (difference -0.2%, 95% CI, -0.4% to 0.7%; P = .56). The clinical manifestation of acute blood transfusion

  11. What is the optimal management of an intra-operative air leak in a colorectal anastomosis?

    PubMed

    Mitchem, J B; Stafford, C; Francone, T D; Roberts, P L; Schoetz, D J; Marcello, P W; Ricciardi, R

    2018-02-01

    An airtight anastomosis on intra-operative leak testing has been previously demonstrated to be associated with a lower risk of clinically significant postoperative anastomotic leak following left-sided colorectal anastomosis. However, to date, there is no consistently agreed upon method for management of an intra-operative anastomotic leak. Therefore, we powered a noninferiority study to determine whether suture repair alone was an appropriate strategy for the management of an intra-operative air leak. This is a retrospective cohort analysis of prospectively collected data from a tertiary care referral centre. We included all consecutive patients with left-sided colorectal or ileorectal anastomoses and evidence of air leak during intra-operative leak testing. Patients were excluded if proximal diversion was planned preoperatively, a pre-existing proximal diversion was present at the time of surgery or an anastomosis was ultimately unable to be completed. The primary outcome measure was clinically significant anastomotic leak, as defined by the Surgical Infection Study Group at 30 days. From a sample of 2360 patients, 119 had an intra-operative air leak during leak testing. Sixty-eight patients underwent suture repair alone and 51 underwent proximal diversion or anastomotic reconstruction. The clinically significant leak rate was 9% (6/68; 95% CI: 2-15%) in the suture repair alone arm and 0% (0/51) in the diversion or reconstruction arm. Suture repair alone does not meet the criteria for noninferiority for the management of intra-operative air leak during left-sided colorectal anastomosis. Further repair of intra-operative air leak by suture repair alone should be reconsidered given these findings. Colorectal Disease © 2017 The Association of Coloproctology of Great Britain and Ireland.

  12. Targeted therapy in esophageal cancer.

    PubMed

    Zhang, Lei; Ma, Jiaojiao; Han, Yu; Liu, Jinqiang; Zhou, Wei; Hong, Liu; Fan, Daiming

    2016-01-01

    An increasing number of patients are diagnosed with esophageal cancer at an advanced stages, and only a small group of them can benefit from the traditional chemotherapy and radiotherapy. So far, multiple monoclonal antibodies and tyrosine kinase inhibitors have been developed, alone or in combination with traditional therapy, to improve the prognosis of patients with advanced esophageal cancer. This review summarizes the recent advances of targeted therapies against EGFR, HER2, VEGFR and c-MET in esophageal cancer. More clinical trials should be performed to evaluate the efficacy and safety of various targeted therapy regimens. Future basic research should focus on investigating the molecular mechanisms of therapeutic targets in esophageal cancer.

  13. Intraoperative brain tumor resection cavity characterization with conoscopic holography

    NASA Astrophysics Data System (ADS)

    Simpson, Amber L.; Burgner, Jessica; Chen, Ishita; Pheiffer, Thomas S.; Sun, Kay; Thompson, Reid C.; Webster, Robert J., III; Miga, Michael I.

    2012-02-01

    Brain shift compromises the accuracy of neurosurgical image-guided interventions if not corrected by either intraoperative imaging or computational modeling. The latter requires intraoperative sparse measurements for constraining and driving model-based compensation strategies. Conoscopic holography, an interferometric technique that measures the distance of a laser light illuminated surface point from a fixed laser source, was recently proposed for non-contact surface data acquisition in image-guided surgery and is used here for validation of our modeling strategies. In this contribution, we use this inexpensive, hand-held conoscopic holography device for intraoperative validation of our computational modeling approach to correcting for brain shift. Laser range scan, instrument swabbing, and conoscopic holography data sets were collected from two patients undergoing brain tumor resection therapy at Vanderbilt University Medical Center. The results of our study indicate that conoscopic holography is a promising method for surface acquisition since it requires no contact with delicate tissues and can characterize the extents of structures within confined spaces. We demonstrate that for two clinical cases, the acquired conoprobe points align with our model-updated images better than the uncorrected images lending further evidence that computational modeling approaches improve the accuracy of image-guided surgical interventions in the presence of soft tissue deformations.

  14. Risk factors for acute cholecystitis and for intraoperative complications.

    PubMed

    Andercou, Octavian; Olteanu, Gabriel; Mihaileanu, Florin; Stancu, Bogdan; Dorin, Marian

    2017-01-01

    Acute cholecystitis is still frequent in emergency surgical departments. As surgical technique, nowadays laparoscopy is widely used and with low complications and with low postoperative morbidity. We perform an analytical study about the safety of laparoscopic surgery in patients with acute cholecystitis in a single Surgical Department with an experience of over 20 years in laparoscopic surgery. We included 193 patient admitted in our department during 2014 and 2015. Of the 193 patients, 43% were diagnosed with acute lithiasic cholecystitis (ALC) whereas 56% had chronic lithiasic cholecystitis (CLC). We assessed the comorbidities of the patient via Pearson's Chi-Square test and we found out that there is a significant relationship between acute cholecystitis and high blood tension, obesity and diabetes. Surgical techniques performed were in 95% of cases laparoscopic cholecystectomy and only in 5% we performed open surgery. Experienced surgeons have a lower conversion rate as compared to less experienced surgeons. For this reason, postoperative assessment criteria have been proposed, with a view to identify the risk of conversion CONCLUSION: In our study laparoscopic surgery for acute cholecystitis is a safe procedure with low intraoperative complication rate and with a reduced hospital stay. Acute cholecystitis, Intraoperative adhesion, Intraoperative bleeding, Laparoscopic cholecystectomy.

  15. Inorganic chemistry in nuclear imaging and radiotherapy: current and future directions

    PubMed Central

    Carroll, Valerie; Demoin, Dustin W.; Hoffman, Timothy J; Jurisson, Silvia S

    2013-01-01

    Summary Radiometals play an important role in diagnostic and therapeutic radiopharmaceuticals. This field of radiochemistry is multidisciplinary, involving radiometal production, separation of the radiometal from its target, chelate design for complexing the radiometal in a biologically stable environment, specific targeting of the radiometal to its in vivo site, and nuclear imaging and/or radiotherapy applications of the resultant radiopharmaceutical. The critical importance of inorganic chemistry in the design and application of radiometal-containing imaging and therapy agents is described from a historical perspective to future directions. PMID:25382874

  16. [Clinical experience of carbon ion radiotherapy for malignant tumors].

    PubMed

    Ishikawa, Hitoshi; Tsuji, Hiroshi; Tsujii, Hirohiko

    2006-04-01

    The carbon ion (C-ion) beams provide unique advantageous biological and physical properties in radiotherapy (RT) for malignant tumors. C-ion beams have a high relative biological effectiveness (RBE) resulting from the high linear energy transfer (LET). In terms of their physical characteristics, C-ion beams exhibit a spread-out Bragg peak (SOBP) and make for a better dose distribution of the target volume by specified beam modulations. Between June 1994 and August 2005, a total of 2,371 patients with malignant tumors were registered in phase I/II dose-escalation studies and clinical phase II trials using C-ion beams generated at Heavy Ion Medical Accelerator in Chiba (HIMAC). In the initial dose-escalation studies, grade 3 or more late rectal complications had developed in some patients. However, the adverse effects were resolved because of the use of appropriate dose levels and modification of the radiation technique. C-ion beams can carry out hypofractionated radiotherapy with a large fraction dose and reduce the overall treatment times compared with conventional radiotherapy. They can also achieve better local tumor control even for radio-resistant tumors such as malignant melanoma, hepatocellular carcinoma and bone and soft tissue sarcomas with minimal morbidity to the normal surrounding tissues.

  17. Prostate tissue ablation with MRI guided transurethral therapeutic ultrasound and intraoperative assessment of the integrity of the neurovascular bundle

    NASA Astrophysics Data System (ADS)

    Sammet, Steffen; Partanen, Ari; Yousuf, Ambereen; Wardrip, Craig; Niekrasz, Marek; Antic, Tatjana; Razmaria, Aria; Sokka, Sham; Karczmar, Gregory; Oto, Aytekin

    2017-03-01

    OBJECTIVES: Evaluation of the precision of prostate tissue ablation with MRI guided therapeuticultrasound by intraoperative objective assessment of the neurovascular bundle in canines in-vivo. METHODS: In this ongoing IACUC approved study, eight male canines were scanned in a clinical 3T Achieva MRI scanner (Philips) before, during, and after ultrasound therapy with a prototype MR-guided ultrasound therapy system (Philips). The system includes a therapy console to plan treatment, to calculate real-time temperature maps, and to control ultrasound exposures with temperature feedback. Atransurethral ultrasound applicator with eight transducer elements was used to ablate canine prostate tissue in-vivo. Ablated prostate tissue volumes were compared to the prescribed target volumes to evaluate technical effectiveness. The ablated volumes determined by MRI (T1, T2, diffusion, dynamic contrast enhanced and 240 CEM43 thermal dose maps) were compared to H&E stained histological slides afterprostatectomy. Potential nerve damage of the neurovascular bundle was objectively assessed intraoperativelyduring prostatectomy with a CaverMap Surgical Aid nerve stimulator (Blue Torch Medical Technologies). RESULTS: Transurethral MRI -guided ultrasound therapy can effectively ablate canine prostate tissue invivo. Coronal MR-imaging confirmed the correct placement of the HIFU transducer. MRI temperature maps were acquired during HIFU treatment, and subsequently used for calculating thermal dose. Prescribed target volumes corresponded to the 240 CEM43 thermal dose maps during HIFU treatment in all canines. Ablated volumes on high resolution anatomical, diffusion weighted, and contrast enhanced MR images matched corresponding histological slides after prostatectomy. MRI guidance with realtime temperature monitoring showed no damage to surrounding tissues, especially to the neurovascular bundle (assessed intra-operatively with a nerve stimulator) or to the rectum wall. CONCLUSIONS: Our study

  18. Can we trust intraoperative culture results in nonunions?

    PubMed

    Palmer, Michael P; Altman, Daniel T; Altman, Gregory T; Sewecke, Jeffrey J; Ehrlich, Garth D; Hu, Fen Z; Nistico, Laura; Melton-Kreft, Rachel; Gause, Trent M; Costerton, John W

    2014-07-01

    To identify the presence of bacterial biofilms in nonunions comparing molecular techniques (multiplex polymerase chain reaction and mass spectrometry, fluorescent in situ hybridization) with routine intraoperative cultures. Thirty-four patients with nonunions were scheduled for surgery and enrolled in this ongoing prospective study. Intraoperative specimens were collected from removed implants, surrounding tissue membrane, and local soft tissue followed by standard culture analysis, Ibis's second generation molecular diagnostics (Ibis Biosystems), and bacterial 16S rRNA-based fluorescence in situ hybridization (FISH). Confocal microscopy was used to visualize the tissue specimens reacted with the FISH probes, which were chosen based on the Ibis analysis. Thirty-four patient encounters were analyzed. Eight were diagnosed as infected nonunions by positive intraoperative culture results. Ibis confirmed the presence of bacteria in all 8 samples. Ibis identified bacteria in a total of 30 of 34 encounters, and these data were confirmed by FISH. Twenty-two of 30 Ibis-positive samples were culture-negative. Four samples were negative by all methods of analysis. No samples were positive by culture, but negative by molecular techniques. Our preliminary data indicate that molecular diagnostics are more sensitive for identifying bacteria than cultures in cases of bony nonunion. This is likely because of the inability of cultures to detect biofilms and bacteria previously exposed to antibiotic therapy. Diagnostic Level I. See Instructions for Authors for a complete description of levels of evidence.

  19. FTO regulates the chemo-radiotherapy resistance of cervical squamous cell carcinoma (CSCC) by targeting β-catenin through mRNA demethylation.

    PubMed

    Zhou, Shun; Bai, Zhou-Lan; Xia, Di; Zhao, Zhi-Jun; Zhao, Ren; Wang, Yan-Yang; Zhe, Hong

    2018-05-01

    The role of N 6 -methyladenosine (m 6 A) demethylase fat mass and obesity-associated protein (FTO) in the regulation of chemo-radiotherapy resistance remains largely unknown. Here, we show that the mRNA level of FTO is elevated in cervical squamous cell carcinoma (CSCC) tissues when compared with respective adjacent normal tissues. FTO enhances the chemo-radiotherapy resistance both in vitro and in vivo through regulating expression of β-catenin by reducing m 6 A levels in its mRNA transcripts and in turn increases excision repair cross-complementation group 1 (ERCC1) activity. Clinically, the prognostic value of FTO for overall survival is found to be dependent on β-catenin expression in human CSCC samples. Taken together, these findings uncover a critical function for FTO and its substrate m 6 A in the regulation of chemo-radiotherapy resistance, which may bear potential clinical implications for CSCC treatment. © 2018 Wiley Periodicals, Inc.

  20. Retrospective evaluation of dosimetric quality for prostate carcinomas treated with 3D conformal, intensity modulated and volumetric modulated arc radiotherapy

    PubMed Central

    Crowe, Scott B; Kairn, Tanya; Middlebrook, Nigel; Hill, Brendan; Christie, David R H; Knight, Richard T; Kenny, John; Langton, Christian M; Trapp, Jamie V

    2013-01-01

    Introduction This study examines and compares the dosimetric quality of radiotherapy treatment plans for prostate carcinoma across a cohort of 163 patients treated across five centres: 83 treated with three-dimensional conformal radiotherapy (3DCRT), 33 treated with intensity modulated radiotherapy (IMRT) and 47 treated with volumetric modulated arc therapy (VMAT). Methods Treatment plan quality was evaluated in terms of target dose homogeneity and organs at risk (OAR), through the use of a set of dose metrics. These included the mean, maximum and minimum doses; the homogeneity and conformity indices for the target volumes; and a selection of dose coverage values that were relevant to each OAR. Statistical significance was evaluated using two-tailed Welch's T-tests. The Monte Carlo DICOM ToolKit software was adapted to permit the evaluation of dose metrics from DICOM data exported from a commercial radiotherapy treatment planning system. Results The 3DCRT treatment plans offered greater planning target volume dose homogeneity than the other two treatment modalities. The IMRT and VMAT plans offered greater dose reduction in the OAR: with increased compliance with recommended OAR dose constraints, compared to conventional 3DCRT treatments. When compared to each other, IMRT and VMAT did not provide significantly different treatment plan quality for like-sized tumour volumes. Conclusions This study indicates that IMRT and VMAT have provided similar dosimetric quality, which is superior to the dosimetric quality achieved with 3DCRT. PMID:26229621

  1. The Ahmed Versus Baerveldt study: design, baseline patient characteristics, and intraoperative complications.

    PubMed

    Christakis, Panos G; Tsai, James C; Zurakowski, David; Kalenak, Jeffrey W; Cantor, Louis B; Ahmed, Iqbal I K

    2011-11-01

    To report the design, baseline patient characteristics, and intraoperative complications of the Ahmed Versus Baerveldt (AVB) Study. Multicenter, randomized, clinical trial. Patients were recruited from 7 international clinical sites and treated by 10 surgeons between 2005 and 2009. Inclusion criteria required that patients be at least 18 years of age and have uncontrolled glaucoma refractory to medicinal, laser, and surgical therapy. Eligible patients were randomized to undergo implantation of an Ahmed-FP7 valve (New World Medical, Inc., Rancho Cucamonga, CA) or a Baerveldt-350 implant (Abbott Medical Optics, Inc., Santa Ana, CA) using standardized surgical technique, to be followed for 5 years. The primary outcome measure was failure, defined as intraocular pressure (IOP) out of target range (5-18 mmHg with ≥ 20% reduction from baseline) for 2 consecutive visits after 3 months, vision-threatening complications, additional glaucoma procedures, or loss of light perception. Secondary outcome measures included IOP, medication use, visual acuity, complications, and interventions. A total of 238 patients were enrolled in the study; 124 received the Ahmed-FP7 valve implant and 114 received the Baerveldt-350 implant. The 2 treatment groups did not differ in any baseline characteristics with the exception of sex. The mean age of the study group was 66 ± 16 years, and 55% were women, with a greater proportion in the Baerveldt group (P=0.01). The mean baseline IOP of the study group was 31.4 ± 10.8 on a mean of 3.1 ± 1.0 glaucoma medications. The median Snellen visual acuity was 20/100, mean number of previous laser therapies was 0.9 ± 1.1, and mean number of previous surgeries was 1.7 ± 1.2. Five (4%) patients in the Ahmed group and 4 (4%) patients in the Baerveldt group experienced significant intraoperative complications. Aqueous drainage devices are being increasingly used for glaucoma refractory to conventional treatment, and the AVB Study compares the 2 most

  2. Method comparison of ultrasound and kilovoltage x-ray fiducial marker imaging for prostate radiotherapy targeting

    NASA Astrophysics Data System (ADS)

    Fuller, Clifton David; Thomas, Charles R., Jr.; Schwartz, Scott; Golden, Nanalei; Ting, Joe; Wong, Adrian; Erdogmus, Deniz; Scarbrough, Todd J.

    2006-10-01

    Several measurement techniques have been developed to address the capability for target volume reduction via target localization in image-guided radiotherapy; among these have been ultrasound (US) and fiducial marker (FM) software-assisted localization. In order to assess interchangeability between methods, US and FM localization were compared using established techniques for determination of agreement between measurement methods when a 'gold-standard' comparator does not exist, after performing both techniques daily on a sequential series of patients. At least 3 days prior to CT simulation, four gold seeds were placed within the prostate. FM software-assisted localization utilized the ExacTrac X-Ray 6D (BrainLab AG, Germany) kVp x-ray image acquisition system to determine prostate position; US prostate targeting was performed on each patient using the SonArray (Varian, Palo Alto, CA). Patients were aligned daily using laser alignment of skin marks. Directional shifts were then calculated by each respective system in the X, Y and Z dimensions before each daily treatment fraction, previous to any treatment or couch adjustment, as well as a composite vector of displacement. Directional shift agreement in each axis was compared using Altman-Bland limits of agreement, Lin's concordance coefficient with Partik's grading schema, and Deming orthogonal bias-weighted correlation methodology. 1019 software-assisted shifts were suggested by US and FM in 39 patients. The 95% limits of agreement in X, Y and Z axes were ±9.4 mm, ±11.3 mm and ±13.4, respectively. Three-dimensionally, measurements agreed within 13.4 mm in 95% of all paired measures. In all axes, concordance was graded as 'poor' or 'unacceptable'. Deming regression detected proportional bias in both directional axes and three-dimensional vectors. Our data suggest substantial differences between US and FM image-guided measures and subsequent suggested directional shifts. Analysis reveals that the vast majority of

  3. Intraoperative endoscopic ultrasound guidance for laparoscopic excision of invisible symptomatic deep intramural myomas.

    PubMed

    Urman, Bulent; Boza, Aysen; Ata, Baris; Aksu, Sertan; Arslan, Tonguc; Taskiran, Cagatay

    2018-01-01

    The aim of this study was to evaluate the feasibility of intraoperative endoscopic ultrasound guidance for excision of symptomatic deep intramural myomas that are not otherwise visible at laparoscopy. Seventeen patients with symptomatic deep intramural myomas who underwent laparoscopic myomectomy with intraoperative endoscopic ultrasound guidance were followed up and reported. All myomas were removed successfully. The endometrium was breached in one patient. All patients were relieved of their symptoms and three patients presenting with infertility conceived. There were no short- or long-term complications associated with the procedure. One patient who had multiple myomas necessitated intravenous iron treatment prior to discharge. Laparoscopic removal of small symptomatic deep intramural myomas is facilitated by the use of intraoperative endoscopic ultrasound that enables exact localisation and correct placement of the serosal incision. Impact statement What is already known on this subject: When the myoma is symptomatic, compressing the endometrium, does not show serosal protrusion and is not amenable to hysteroscopic resection, laparoscopic surgery may become challenging. What do the results of this study add: The use of intraoperative endoscopic ultrasound under these circumstances may facilitate the procedure by accurate identification of the myoma and correct placement of the serosal incision. What are the implications of these findings for clinical practice and/or further research: Intraoperative ultrasound should be more oftenly used to accurately locate deep intramural myomas to the end of making laparoscopy feasible and possibly decreasing recurrence by facilitating removal of otherwise unidentifiable disease.

  4. Early Experience with Combining Awake Craniotomy and Intraoperative Navigable Ultrasound for Resection of Eloquent Region Gliomas.

    PubMed

    Moiyadi, Aliasgar; Shetty, Prakash

    2017-03-01

    Introduction  Optimal resection of tumors in eloquent locations requires a combination of intraoperative imaging and functional monitoring during surgery. Combining awake surgery with intraoperative magnetic resonanceis logistically challenging. Navigable ultrasound (US) is a useful alternative in such cases. Methods  A total of 22 subjects with eloquent tumors were operated on (1 intended biopsy and 21 intended radical resections) using combined modality three-dimensional (3D) US and awake craniotomy with intraoperative clinical monitoring. We describe the technical details for these cases specifically addressing the feasibility of combining the two modalities. Results  US was used for resection control in 18 cases. There were technical limitations in three cases. Transient intraoperative worsening was encountered in eight, necessitating premature termination of the procedure. All patients tolerated the awake procedure well. Mean duration of the surgery was 3.2 hours. Radical resections were obtained in 14 of 18 where this was intended and in 12 of the 13 where there was no adverse intraoperative monitoring event prompting premature termination of the resection. Conclusions  Combining awake surgery with 3DUS is feasible and beneficial. It does not entail any additional surgical workflow modification or patient discomfort. This combined modality intraoperative monitoring can be beneficial for eloquent region tumors. Georg Thieme Verlag KG Stuttgart · New York.

  5. Intraoperative low tidal volume ventilation strategy has no benefits during laparoscopic cholecystectomy

    PubMed Central

    Arora, Vandna; Tyagi, Asha; Kumar, Surendra; Kakkar, Aanchal; Das, Shukla

    2017-01-01

    Background and Aims: Benefits of intraoperative low tidal volume ventilation during laparoscopic surgery are not conclusively proven, even though its advantages were seen in other situations with intraoperative respiratory compromise such as one-lung ventilation. The present study compared the efficacy of intraoperative low tidal volume ventilatory strategy (6 ml/kg along with positive end-expiratory pressure [PEEP] of 10 cmH2O) versus one with higher tidal volume (10 ml/kg with no PEEP) on various clinical parameters and plasma levels of interleukin (IL)-6 in patients undergoing laparoscopic cholecystectomy. Material and Methods: A total of 58 adult patients with American Society of Anesthesiologists physical status I or II, undergoing laparoscopic cholecystectomy were randomized to receive the low or higher tidal volume strategy as above (n = 29 each). The primary outcome measure was postoperative PaO2. Systemic levels of IL-6 along with clinical indices of intraoperative gas exchange, pulmonary mechanics, and hemodynamic consequences were measured as secondary outcome measures. Results: There was no statistically significant difference in oxygenation; intraoperative dynamic compliance, peak airway pressures, or hemodynamic parameters, or the IL-6 levels between the two groups (P > 0.05). Low tidal volume strategy was associated with significantly higher mean airway pressure, lower airway resistance, greater respiratory rates, and albeit clinically similar, higher PaCO2and lower pH (P < 0.05). Conclusion: Strategy using 6 ml/kg tidal volume along with 10 cmH2O of PEEP was not associated with any significant improvement in gas exchange, hemodynamic parameters, or systemic inflammatory response over ventilation with 10 ml/kg volume without PEEP during laparoscopic cholecystectomy. PMID:28413273

  6. Postoperative acute kidney injury following intraoperative blood product transfusions during cardiac surgery.

    PubMed

    Kindzelski, Bogdan A; Corcoran, Philip; Siegenthaler, Michael P; Horvath, Keith A

    2018-01-01

    This study explored the nature of the association between intraoperative usage of red blood cell, fresh frozen plasma, cryoprecipitate or platelet transfusions and acute kidney injury. A total of 1175 patients who underwent cardiac surgery between 2008 and 2013 were retrospectively analyzed. We assessed the association between: (1) preoperative patient characteristics and acute kidney injury, (2) intraoperative blood product usage and acute kidney injury, (3) acute kidney injury and 30-day mortality or re-hospitalization. In our cohort of 1175 patients, 288 patients (24.5%) developed acute kidney injury. This included 162 (13.8%), 69 (5.9%) and 57 (4.9%) developing stage 1, stage 2 or stage 3 acute kidney injury, respectively. Increased red blood cell, fresh frozen plasma or platelet transfusions increased the odds of developing acute kidney injury. Specifically, every unit of red blood cells, fresh frozen plasma or platelets transfused was associated with an increase in the covariate-adjusted odds ratio of developing ⩾ stage 2 kidney injury of 1.18, 1.19 and 1.04, respectively. Intraoperative blood product transfusions were independently associated with an increased odds of developing acute kidney injury following cardiac surgery. Further randomized studies are needed to better define intraoperative transfusion criteria.

  7. Initial experience of using high field strength intraoperative MRI for neurosurgical procedures.

    PubMed

    Raheja, Amol; Tandon, Vivek; Suri, Ashish; Sarat Chandra, P; Kale, Shashank S; Garg, Ajay; Pandey, Ravindra M; Kalaivani, Mani; Mahapatra, Ashok K; Sharma, Bhawani S

    2015-08-01

    We report our initial experience to optimize neurosurgical procedures using high field strength intraoperative magnetic resonance imaging (IOMRI) in 300 consecutive patients as high field strength IOMRI rapidly becomes the standard of care for neurosurgical procedures. Three sequential groups (groups A, B, C; n=100 each) were compared with respect to time management, complications and technical difficulties to assess improvement in these parameters with experience. We observed a reduction in the number of technical difficulties (p<0.001), time to induction (p<0.001) and total anesthesia time (p=0.007) in sequential groups. IOMRI was performed for neuronavigation guidance (n=252) and intraoperative validation of extent of resection (EOR; n=67). Performing IOMRI increased the EOR over and beyond the primary surgical attempt in 20.5% (29/141) and 18% (11/61) of patients undergoing glioma and pituitary surgery, respectively. Overall, EOR improved in 59.7% of patients undergoing IOMRI (40/67). Intraoperative tractography and real time navigation using re-uploaded IOMRI images (accounting for brain shift) helps in intraoperative planning to reduce complications. IOMRI is an asset to neurosurgeons, helping to augment the EOR, especially in glioma and pituitary surgery, with no significant increase in morbidity to the patient. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. The role of intraoperative parathyroid hormone testing in patients with tertiary hyperparathyroidism after renal transplantation.

    PubMed

    Haustein, Silke V; Mack, Eberhard; Starling, James R; Chen, Herbert

    2005-12-01

    Intraoperative parathyroid hormone (PTH) testing has been shown to accurately define adequacy of parathyroid resection in patients with primary hyperparathyroidism (HPT) and alters the operative management in 10% to 15% of cases. However, the benefit of this technique in patients with tertiary HPT after renal transplantation undergoing parathyroidectomy is unclear. Intraoperative PTH was measured in 32 consecutive patients undergoing parathyroidectomy for tertiary HPT after renal transplantation between March 2001 and November 2004 by using the Elecsys assay at baseline and, subsequently, 5, 10, and 15 minutes after curative resection. The outcomes of these patients were evaluated. All patients were cured after surgery. Of the 32 patients, 29 were found to have parathyroid hyperplasia, while 1 had a single adenoma and 2 had double adenomas. The average drop in intraoperative PTH levels after curative resection was 69 +/- 3.5% at 5 min., 77 +/- 2.3% at 10 minutes, and 83 +/- 3.4% at 15 minutes. PTH testing changed the intraoperative management in 5 (16%) patients. One patient with a single adenoma and 2 patients with double adenomas had a >50% drop at 10 minutes. after excision; therefore, the operation was terminated without further resection. Two patients did not have a >50% drop at 10 minutes after 3.5 gland resection. These patients were explored further, and additional supernumerary parathyroid glands were identified and resected. After resection of these additional glands, the PTH fell by >50%, indicating cure. In patients undergoing parathyroidectomy for tertiary HPT after renal transplantation, a decrease in intraoperative PTH levels >50% at 10 minutes after completion of the operation indicated adequate resection. Furthermore, intraoperative PTH testing altered the operative management in 16% of patients. Therefore, similar to its role in patients with primary HPT, intraoperative PTH testing appears to play an equally important role in the management of

  9. Warmed, humidified CO2 insufflation benefits intraoperative core temperature during laparoscopic surgery: A meta‐analysis

    PubMed Central

    Dean, Meara; Ramsay, Robert; Heriot, Alexander; Mackay, John; Hiscock, Richard

    2016-01-01

    Abstract Background Intraoperative hypothermia is linked to postoperative adverse events. The use of warmed, humidified CO2 to establish pneumoperitoneum during laparoscopy has been associated with reduced incidence of intraoperative hypothermia. However, the small number and variable quality of published studies have caused uncertainty about the potential benefit of this therapy. This meta‐analysis was conducted to specifically evaluate the effects of warmed, humidified CO2 during laparoscopy. Methods An electronic database search identified randomized controlled trials performed on adults who underwent laparoscopic abdominal surgery under general anesthesia with either warmed, humidified CO2 or cold, dry CO2. The main outcome measure of interest was change in intraoperative core body temperature. Results The database search identified 320 studies as potentially relevant, and of these, 13 met the inclusion criteria and were included in the analysis. During laparoscopic surgery, use of warmed, humidified CO2 is associated with a significant increase in intraoperative core temperature (mean temperature change, 0.3°C), when compared with cold, dry CO2 insufflation. Conclusion Warmed, humidified CO2 insufflation during laparoscopic abdominal surgery has been demonstrated to improve intraoperative maintenance of normothermia when compared with cold, dry CO2. PMID:27976517

  10. Laparoscopy vs robotics in surgical management of endometrial cancer: comparison of intraoperative and postoperative complications.

    PubMed

    Seror, Julien; Bats, Anne-Sophie; Huchon, Cyrille; Bensaïd, Chérazade; Douay-Hauser, Nathalie; Lécuru, Fabrice

    2014-01-01

    To compare the rates of intraoperative and postoperative complications of robotic surgery and laparoscopy in the surgical treatment of endometrial cancer. Unicentric retrospective study (Canadian Task Force classification II-2). Tertiary teaching hospital. The study was performed from January 2002 to December 2011 and included patients with endometrial cancer who underwent laparoscopic or robotically assisted laparoscopic surgical treatment. Data collected included preoperative data, tumor characteristics, intraoperative data (route of surgery, surgical procedures, and complications), and postoperative data (early and late complications according to the Clavien-Dindo classification, and length of hospital stay). Morbidity was compared between the 2 groups. The study included 146 patients, of whom 106 underwent laparoscopy and 40 underwent robotically assisted surgery. The 2 groups were comparable in terms of demographic and preoperative data. Intraoperative complications occurred in 9.4% of patients who underwent laparoscopy and in none who underwent robotically assisted surgery (p = .06). There was no difference between the 2 groups in terms of postoperative events. Robotically assisted surgery is not associated with a significant difference in intraoperative and postoperative complications, even when there were no intraoperative complications of robotically assisted surgery. Copyright © 2014 AAGL. Published by Elsevier Inc. All rights reserved.

  11. Carotid-Sparing Intensity-Modulated Radiotherapy for Early-Stage Squamous Cell Carcinoma of the True Vocal Cord

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chera, Bhishamjit S.; Amdur, Robert J., E-mail: amdurr@shands.ufl.ed; Morris, Christopher G.

    2010-08-01

    Purpose: To compare radiation doses to carotid arteries among various radiotherapy techniques for treatment of early-stage squamous cell carcinoma (SCC) of the true vocal cords. Methods and Materials: Five patients were simulated using computed tomography (CT). Clinical and planning target volumes (PTV) were created for bilateral and unilateral stage T1 vocal cord cancers. Planning risk volumes for the carotid arteries and spinal cord were delineated. For each patient, three treatment plans were designed for bilateral and unilateral target volumes: opposed laterals (LATS), three-dimensional conformal radiotherapy (3DCRT), and intensity-modulated radiotherapy (IMRT), for a total of 30 plans. More than 95% ofmore » the PTV received the prescription dose (63Gy at 2.25 Gy per treatment). Results: Carotid dose was lowest with IMRT. With a bilateral vocal cord target, the median carotid dose was 10Gy with IMRT vs. 25 Gy with 3DCRT and 38 Gy with LATS (p < 0.05); with a unilateral target, the median carotid dose was 4 Gy with IMRT vs. 19 Gy with 3DCRT and 39 Gy with LATS (p < 0.05). The dosimetric tradeoff with IMRT is a small area of high dose in the PTV. The worst heterogeneity results were at a maximum point dose of 80 Gy (127%) in a unilateral target that was close to the carotid. Conclusions: There is no question that IMRT can reduce the dose to the carotid arteries in patients with early-stage vocal cord cancer. The question is whether the potential advantage of reducing the carotid dose outweighs the risk of tumor recurrence due to contouring errors and organ motion and the risk of complications from dose heterogeneity.« less

  12. Measuring the inequalities in radiotherapy health resources in Japan: comparison of the Hokkaido-Tohoku and Tokyo districts.

    PubMed

    Ohba, Hisateru; Narumi, Masakazu; Hosokawa, Yoichiro; Aoki, Masahiko

    2010-01-01

    The aim of this study was to measure and compare the geographical inequalities in radiotherapy health resources between the Hokkaido-Tohoku and Tokyo districts of Japan. The numbers of radiotherapy facilities, radiologists, and radiological technologists were used to represent radiotherapy health resources. The target areas were 11 prefectures in the Hokkaido-Tohoku and Tokyo districts. The Gini coefficient (GC) was used to measure inequalities in health resources in relation to the population and area of each secondary medical care zone. Correlation analysis was performed to clarify the relation between the GC and the all-cancer mortality rate per 100,000 people. The mean population and area GCs of Yamagata Prefecture were the smallest, whereas the mean population GC of Tokyo and the mean area GC of Hokkaido were the largest. The mean GCs of radiotherapy facilities and radiological technologists were higher in the Tokyo district than in the Hokkaido-Tohoku district. No significant correlation was found between GC and cancer mortality. Geographical inequalities in radiotherapy health resources tended to be larger in the Tokyo district than in the Hokkaido-Tohoku district. It is expected that the radiotherapy system will be substantially improved by the Basic Plan to Promote Cancer Control Programs.

  13. Role of intraoperative ultrasound in achieving complete resection of intra-axial solid brain tumours.

    PubMed

    Mari, Abdul Razaque; Shah, Irfanullah; Imran, Muhammed; Ashraf, Junaid

    2014-12-01

    To determine the frequency of completeness of resection for intra-axial solid brain tumours with the help of intra-operative ultrasound to detect residual brain tumour. The cross-sectional study was conducted at the Department of Neurosurgery, Dow University of Health Sciences and Civil Hospital Karachi, from September 2009 to June 2010 and comprised patients with intra-axial solid brain lesion. During operation following standard craniotomy, multi-plane sonographic examination was performed using intra-operative ultrasound for tumour localisation and calculation of dimension, followed by tumour resection in the standard fashion. At the end of tumour resection ultrasound was again used for the detection of any residual tumour. Results of intra-operative ultrasound were compared with post-operative contrast magnetic resonance imaging. Of the 39 cases in which intra-operative ultrasound was performed, 32(82.1%) were males and 7(17.9%) were females, with an overall mean age of 42.6±19.7 years. Intra-operative ultrasonography was able to localise and delineate the tumour in all 39 (100%) cases. It showed no residual tumour in 36 (92.3%) cases, but in 3(7.7%) cases residual tumour was detected. Post-operative contrast enhancing magnetic resonance imaging showed no residual tumour in 35(89.7%) cases and in 4(10.3%) cases residual tumour was detected. The frequency of completely resected intra-axial solid brain tumour was 35(89.7%), while in 4(10.3%) cases incomplete resection was observed. The study concluded that intra-operative ultrasonography has an important role in achieving increased frequency of completely resected intra-axial solid brain tumours.

  14. Is there still a role for intraoperative enteroscopy in patients with obscure gastrointestinal bleeding?

    PubMed

    Monsanto, Pedro; Almeida, Nuno; Lérias, Clotilde; Figueiredo, Pedro; Gouveia, Hermano; Sofia, Carlos

    2012-04-01

    in 21st century, endoscopic study of the small intestine has undergone a revolution with capsule endoscopy and balloon-assisted enteroscopy. The difficulties and morbidity associated with intraoperative enteroscopy, the gold-standard in the 20th century, made this technique to be relegated to a second level. evaluate the actual role and assess the diagnostic and therapeutic value of intraoperative enteroscopy in patients with obscure gastrointestinal bleeding. we conducted a retrospective study of 19 patients (11 males; mean age: 66.5 ± 15.3 years) submitted to 21 IOE procedures for obscure GI bleeding. Capsule endoscopy and double balloon enteroscopy had been performed in 10 and 5 patients, respectively. with intraoperative enteroscopy a small bowel bleeding lesion was identified in 79% of patients and a gastrointestinal bleeding lesion in 94%. Small bowel findings included: angiodysplasia (n = 6), ulcers (n = 4), small bowel Dieulafoy´s lesion (n = 2), bleeding from anastomotic vessels (n = 1), multiple cavernous hemangiomas (n = 1) and bleeding ectopic jejunal varices (n = 1). Agreement between capsule endoscopy and intraoperative enteroscopy was 70%. Endoscopic and/or surgical treatment was used in 77.8% of the patients with a positive finding on intraoperative enteroscopy, with a rebleeding rate of 21.4% in a mean 21-month follow-up period. Procedure-related mortality and postoperative complications have been 5 and 21%, respectively. intraoperative enteroscopy remains a valuable tool in selected patients with obscure GI bleeding, achieving a high diagnostic yield and allowing an endoscopic and/or surgical treatment in most of them. However, as an invasive procedure with relevant mortality and morbidity, a precise indication for its use is indispensable.

  15. Routine intra-operative trans-oesophageal echocardiography yields better outcomes in surgical repair of CHD.

    PubMed

    Madriago, Erin J; Punn, Rajesh; Geeter, Natalie; Silverman, Norman H

    2016-02-01

    Trans-oesophageal echocardiographic imaging is valuable in the pre- and post-operative evaluation of children and adults with CHD; however, the frequency by which trans-oesophageal echocardiography guides the intra-operative course of patients is unknown. We retrospectively reviewed 1748 intra-operative trans-oesophageal echocardiograms performed between 1 October, 2005 and 31 December, 2010, and found 99 cases (5.7%) that required return to bypass, based in part upon the intra-operative echocardiographic findings. The diagnoses most commonly requiring further repair and subsequent imaging were mitral valve disease (20.9%), tricuspid valve disease (16.0%), atrioventricular canal defects (12.0%), and pulmonary valve disease (14.1%). The vast majority of those requiring immediate return to bypass benefited by avoiding subsequent operations and longer lengths of hospital stay. A total of 14 patients (0.8%) who received routine imaging required further surgical repair within 1 week, usually due to disease that developed over ensuing days. Patients who had second post-operative trans-oesophageal echocardiograms in the operating room rarely required re-operations, confirming the benefit of routine intra-operative imaging. This study represents a large single institutional review of intra-operative trans-oesophageal echocardiography, and confirms its applicability in the surgical repair of patients with CHD. Routine imaging accurately identifies patients requiring further intervention, does not confer additional risk of mortality or prolonged length of hospital stay, and prevents subsequent operations and associated sequelae in a substantial subset of patients. This study demonstrates the utility of echocardiography in intra-operative monitoring of surgical repair and highlights patients who are most likely to require return to bypass, as well as the co-morbidities of such manipulations.

  16. Precision IORT - Image guided intraoperative radiation therapy (igIORT) using online treatment planning including tissue heterogeneity correction.

    PubMed

    Schneider, Frank; Bludau, Frederic; Clausen, Sven; Fleckenstein, Jens; Obertacke, Udo; Wenz, Frederik

    2017-05-01

    To the present date, IORT has been eye and hand guided without treatment planning and tissue heterogeneity correction. This limits the precision of the application and the precise documentation of the location and the deposited dose in the tissue. Here we present a set-up where we use image guidance by intraoperative cone beam computed tomography (CBCT) for precise online Monte Carlo treatment planning including tissue heterogeneity correction. An IORT was performed during balloon kyphoplasty using a dedicated Needle Applicator. An intraoperative CBCT was registered with a pre-op CT. Treatment planning was performed in Radiance using a hybrid Monte Carlo algorithm simulating dose in homogeneous (MCwater) and heterogeneous medium (MChet). Dose distributions on CBCT and pre-op CT were compared with each other. Spinal cord and the metastasis doses were evaluated. The MCwater calculations showed a spherical dose distribution as expected. The minimum target dose for the MChet simulations on pre-op CT was increased by 40% while the maximum spinal cord dose was decreased by 35%. Due to the artefacts on the CBCT the comparison between MChet simulations on CBCT and pre-op CT showed differences up to 50% in dose. igIORT and online treatment planning improves the accuracy of IORT. However, the current set-up is limited by CT artefacts. Fusing an intraoperative CBCT with a pre-op CT allows the combination of an accurate dose calculation with the knowledge of the correct source/applicator position. This method can be also used for pre-operative treatment planning followed by image guided surgery. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  17. Frame-of-reference training for simulation-based intraoperative communication assessment.

    PubMed

    Gardner, Aimee K; Russo, Michael A; Jabbour, Ibrahim I; Kosemund, Matthew; Scott, Daniel J

    2016-09-01

    The purpose of this study was to examine the impact of frame-of-reference (FOR) training on assessments of intraoperative communication skills and identify areas of need to inform curricular efforts. Simulation instructors (M.D., Ph.D., Research Fellow, Simulation Technician) underwent a 2-hour FOR training session with the operating room communication instrument. They then independently rated communication skills of 19 PGY1s who participated in a team-based simulation. Residents completed self-assessments via video review of the scenario. Intraclass correlation coefficients were used to examine inter-rater reliability. Relationships between trained raters and resident scores were assessed with Pearson correlation coefficients and paired sample t tests. Inter-reliability after FOR training was .91. The correlation between trained rater scores and resident evaluations was nonsignificant. Residents significantly underestimated their intraoperative communication skills (P < .05). Use of names, closed loop communication, and sharing information with team members demonstrated consistently low ratings among all residents. These findings reveal that a number of individuals can be trained to reliably rate resident intraoperative communication performance and that residents tend to under-rate their communication skills. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Intraoperative imaging-guided cancer surgery: from current fluorescence molecular imaging methods to future multi-modality imaging technology.

    PubMed

    Chi, Chongwei; Du, Yang; Ye, Jinzuo; Kou, Deqiang; Qiu, Jingdan; Wang, Jiandong; Tian, Jie; Chen, Xiaoyuan

    2014-01-01

    Cancer is a major threat to human health. Diagnosis and treatment using precision medicine is expected to be an effective method for preventing the initiation and progression of cancer. Although anatomical and functional imaging techniques such as radiography, computed tomography (CT), magnetic resonance imaging (MRI) and positron emission tomography (PET) have played an important role for accurate preoperative diagnostics, for the most part these techniques cannot be applied intraoperatively. Optical molecular imaging is a promising technique that provides a high degree of sensitivity and specificity in tumor margin detection. Furthermore, existing clinical applications have proven that optical molecular imaging is a powerful intraoperative tool for guiding surgeons performing precision procedures, thus enabling radical resection and improved survival rates. However, detection depth limitation exists in optical molecular imaging methods and further breakthroughs from optical to multi-modality intraoperative imaging methods are needed to develop more extensive and comprehensive intraoperative applications. Here, we review the current intraoperative optical molecular imaging technologies, focusing on contrast agents and surgical navigation systems, and then discuss the future prospects of multi-modality imaging technology for intraoperative imaging-guided cancer surgery.

  19. Intraoperative Imaging-Guided Cancer Surgery: From Current Fluorescence Molecular Imaging Methods to Future Multi-Modality Imaging Technology

    PubMed Central

    Chi, Chongwei; Du, Yang; Ye, Jinzuo; Kou, Deqiang; Qiu, Jingdan; Wang, Jiandong; Tian, Jie; Chen, Xiaoyuan

    2014-01-01

    Cancer is a major threat to human health. Diagnosis and treatment using precision medicine is expected to be an effective method for preventing the initiation and progression of cancer. Although anatomical and functional imaging techniques such as radiography, computed tomography (CT), magnetic resonance imaging (MRI) and positron emission tomography (PET) have played an important role for accurate preoperative diagnostics, for the most part these techniques cannot be applied intraoperatively. Optical molecular imaging is a promising technique that provides a high degree of sensitivity and specificity in tumor margin detection. Furthermore, existing clinical applications have proven that optical molecular imaging is a powerful intraoperative tool for guiding surgeons performing precision procedures, thus enabling radical resection and improved survival rates. However, detection depth limitation exists in optical molecular imaging methods and further breakthroughs from optical to multi-modality intraoperative imaging methods are needed to develop more extensive and comprehensive intraoperative applications. Here, we review the current intraoperative optical molecular imaging technologies, focusing on contrast agents and surgical navigation systems, and then discuss the future prospects of multi-modality imaging technology for intraoperative imaging-guided cancer surgery. PMID:25250092

  20. Improvements in the radiotherapy of medulloblastoma, 1946 to 1975

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Landberg, T.G.; Lindgren, M.L.; Cavallin-Staehl, E.K.

    1980-02-01

    The prognosis in medulloblastoma has often been reported to be gloomy, and five-year survival rates of approximately 25% are often reported. In recent years, however, some centers have published results that indicate a possible cure rate of 60% or even more. During the years 1946 to 1975, 50 children received radiotherapy for medulloblastoma at the University Hospital, Lund, Sweden. During this period the target volume had been defined in three different ways, whereas the target-absorbed doses had not differed. When only the demonstrated tumor was treated, the ten-year survival rate was 5%. If the spinal subdural space also was included,more » it rose to 25%, and when the whole subdural space was treated in addition to the demonstrated tumor, the projected ten-year survival rate was 53%. It is apparent that the target volume in the radiotherapy of medulloblastoma should include not only the demonstrated tumor but also the whole subdural space from the tip of the frontal lobes down to and including the second sacral segment. The size of the target-absorbed dose to be aimed at is not settled, but should consider not only the cure rate but also the performance status of the survivors. It seems from the present series that an absorbed dose of 45 Gy in not more than 30 fractions over six weeks to the demonstrated tumor and 30 Gy in 20 fractions over four weeks to the subdural space resulted in a fair frequency of tumor healing and minimal side effects. The delivery of this complicated treatment demands a high degree of precision in the technique. In this material the performance status of the children was not affected by the radiation treatment.« less

  1. Lung reexpansion of obstructive atelectasis caused by radiotherapy after continuous gefitinib treatment in nonsmall cell lung cancer.

    PubMed

    Yang, Xueqin; Xu, Mingfang; Xiong, Yanli; Peng, Bo

    2015-01-01

    A 75-year-old male was diagnosed with central squamous cell carcinoma of the left lung, who has been given 3-dimensional conformal radiotherapy of total dose with 60 Gy in 30 fractions. Three years later, the tumor relapsed in situ and he received another stereotactic radiotherapy with a total dose of 40 Gy at a margin of planning target volume (PTV) in 10 (5 fractions/week) at 4 Gy/fraction. Gefitinib (250 mg/day) was initiated immediately after radiotherapy. Obstructive atelectasis in the left lung and increased pleural effusion occurred at the fourth month after radiotherapy. As this patient has been detected with deletion in exon 19 of the EGFR gene, gefitinib was continuous administered without interruption. After another 4 months, the atelectasis in the left lung reexpanded significantly. To the best of our knowledge, this is the first report in the literature that EGFR tyrosine kinase inhibitors (EGFR-TKI) reversed the radiation atelectasis of pulmonary in the nonsmall cell lung cancer (NSCLC) patient.

  2. Micronuclei and other nuclear anomalies in normal human buccal mucosa cells of oral cancer patients undergoing radiotherapy: a field effect.

    PubMed

    Tak, A; Metgud, R; Astekar, M; Tak, M

    2014-08-01

    We evaluated micronuclei and other nuclear anomalies in exfoliated epithelial cells of the oral cavity on the side opposite the lesion targeted by radiotherapy and correlated them with radiation doses. Buccal smears were obtained from oral cancer patients undergoing radiotherapy with a cumulative dose of at least 1000 rad for 3 weeks and from controls matched for age, gender and habits. The exfoliated cells from the mucosa were collected using a cytobrush; smears were prepared, fixed in 80% methanol and stained using the Feulgen plus fast green method. The mean number of micronuclei and other nuclear anomalies/1000 cells was significantly greater in patients undergoing radiotherapy treatment, but the differences were not significant compared to radiation doses. It appears that radiotherapy has a potent clastogenic effect on buccal mucosal cells of oral cancer patients.

  3. Optical spectroscopy of radiotherapy and photodynamic therapy responses in normal rat skin shows vascular breakdown products

    NASA Astrophysics Data System (ADS)

    Teles de Andrade, Cintia; Nogueira, Marcelo S.; Kanick, Stephen C.; Marra, Kayla; Gunn, Jason; Andreozzi, Jacqueline; Samkoe, Kimberley S.; Kurachi, Cristina; Pogue, Brian W.

    2016-03-01

    Photodynamic therapy (PDT) and radiotherapy are non-systemic cancer treatment options with different mechanisms of damage. So combining these techniques has been shown to have some synergy, and can mitigate their limitations such as low PDT light penetration or radiotherapy side effects. The present study monitored the induced tissue changes after PDT, radiotherapy, and a combination protocol in normal rat skin, using an optical spectroscopy system to track the observed biophysical changes. The Wistar rats were treated with one of the protocols: PDT followed by radiotherapy, PDT, radiotherapy and radiotherapy followed by PDT. Reflectance spectra were collected in order to observe the effects of these combined therapies, especially targeting vascular response. From the reflectance, information about oxygen saturation, met-hemoglobin and bilirubin concentration, blood volume fraction (BVF) and vessel radius were extracted from model fitting of the spectra. The rats were monitored for 24 hours after treatment. Results showed that there was no significant variation in the vessel size or BVF after the treatments. However, the PDT caused a significant increase in the met-hemoglobin and bilirubin concentrations, indicating an important blood breakdown. These results may provide an important clue on how the damage establishment takes place, helping to understand the effect of the combination of those techniques in order to verify the existence of a known synergistic effect.

  4. Evaluation of radiotherapy techniques for radical treatment of lateralised oropharyngeal cancers : Dosimetry and NTCP.

    PubMed

    McQuaid, D; Dunlop, A; Nill, S; Franzese, C; Nutting, C M; Harrington, K J; Newbold, K L; Bhide, S A

    2016-08-01

    The aim of this study was to investigate potential advantages and disadvantages of three-dimensional conformal radiotherapy (3DCRT), multiple fixed-field intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) in terms of dose to the planning target volume (PTV), organs at risk (OARs) and normal tissue complication probability (NTCP) for delivering ipsilateral radiotherapy. 3DCRT, IMRT and VMAT were compared in patients with well-lateralised primary tonsillar cancers who underwent primary radical ipsilateral radiotherapy. The following parameters were compared: conformity index (CI); homogeneity index (HI); dose-volume histograms (DVHs) of PTVs and OARs; NTCP, risk of radiation-induced cancer and dose accumulation during treatment. IMRT and VMAT were superior to 3DCRT in terms of CI, HI and dose to the target volumes, as well as mandible and dose accumulation robustness. The techniques were equivalent in terms of dose and NTCP for the contralateral oral cavity, contralateral submandibular gland and mandible, when specific dose constraint objectives were used on the oral cavity volume. Although the volume of normal tissue exposed to low-dose radiation was significantly higher with IMRT and VMAT, the risk of radiation-induced secondary malignancy was dependant on the mathematical model used. This study demonstrates the superiority of IMRT/VMAT techniques over 3DCRT in terms of dose homogeneity, conformity and consistent dose delivery to the PTV throughout the course of treatment in patients with lateralised oropharyngeal cancers. Dosimetry and NTCP calculations show that these techniques are equivalent to 3DCRT with regard to the risk of acute mucositis when specific dose constraint objectives were used on the contralateral oral cavity OAR.

  5. Intraoperative anaphylaxis secondary to intraosseous gelatin administration.

    PubMed

    Luhmann, Scott J; Sucato, Daniel J; Bacharier, Leonard; Ellis, Alysa; Woerz, Cyndi

    2013-01-01

    FloSeal and SurgiFlo Hemostatic Matrices are commonly used in surgical procedures to promote coagulation and minimize blood loss. They are composed of bovine and porcine gelatin matrix, respectively, that can be injected into pedicles to stop osseous bleeding during pedicle screw insertion. This report details 2 pediatric spinal deformity reconstructive surgery patients who experienced intraoperative cardiovascular events after the intraosseous administration of animal-derived gelatin. Case #1 is an 11-year-old female with adolescent idiopathic scoliosis who was undergoing routine posterior spinal instrumentation and fusion. During placement of the fourth pedicle screw, the patient developed profound hypotension, tachycardia, and elevated airway pressures requiring intravenous epinephrine and phenylephrine for hemodynamic support. Surgery was aborted. Postoperative work-up demonstrated a positive ImmunoCAP study for bovine gelatin. Surgery was repeated 1 week later, without the use of FloSeal, and no episodes of hemodynamic instability. Case #2 was a 9-year-old female with juvenile idiopathic scoliosis who was undergoing a growing spine construct. As in Case #1, SurgiFlo was placed into 2 pedicle tracts after which there was profound hypotension, tachycardia, and elevated airway pressures. Resuscitative efforts included intravenous atropine and epinephrine with resolution. Surgery was aborted. Surgery was repeated 2 weeks later, without the use of SurgiFlo, with no episodes of hemodynamic instability. Given that the patient's symptoms were classic for anaphylaxis, and that the timing of the anaphylaxis immediately followed the administration of FloSeal and SurgiFlo we believe that FloSeal and SurgiFlo were the causes of the reactions. These are the first known reported cases of intraoperative anaphylaxis associated with FloSeal and SurgiFlo. On the basis of our experience, in order to avoid intraoperative cardiovascular events, we obtain preoperative Immuno

  6. Thermoregulatory response to intraoperative head-down tilt.

    PubMed

    Nakajima, Yasufumi; Mizobe, Toshiki; Matsukawa, Takashi; Sessler, Daniel I; Kitamura, Yoshihiro; Tanaka, Yoshifumi

    2002-01-01

    Thermoregulation interacts with cardiovascular regulation within the central nervous system. We therefore evaluated the effects of head-down tilt on intraoperative thermal and cardiovascular regulation. Thirty-two patients undergoing lower-abdominal surgery were randomly assigned to the 1) supine, 2) 15 degrees -20 degrees head-down tilt, 3) leg-up, or 4) combination of leg-up and head-down tilt position. Core temperature and forearm minus fingertip skin-temperature gradients (an index of peripheral vasoconstriction) were monitored for 3 h after the induction of combined general and lumbar epidural anesthesia. We also determined cardiac output and central-venous and esophageal pressures. Neither right atrial transmural pressure nor cardiac index was altered in the Head-Down Tilt group, but both increased significantly in the Leg-Up groups. The vasoconstriction threshold was reduced in both leg-up positions but was not significantly decreased by head-down tilt. Final core temperatures were 35.2 degrees C +/- 0.2 degrees C (mean +/- SEM) in the Supine group, 35.0 degrees C +/- 0.2 degrees C in the Head-Down Tilt group, 34.2 degrees C +/- 0.2 degrees C in the Leg-Up group (P < 0.05 compared with supine), and 34.3 degrees C +/- 0.2 degrees C when leg-up and head-down tilt were combined (P < 0.05 compared with supine). These results confirm that elevating the legs increases right atrial transmural pressure, reduces the vasoconstriction threshold, and aggravates intraoperative hypothermia. Surprisingly, maintaining a head-down tilt did not increase right atrial pressure. Intraoperative hypothermia is exaggerated when patients are maintained in the leg-up position because the vasoconstriction threshold is reduced. However, head-down tilt (Trendelenburg position) does not reduce the vasoconstriction threshold or aggravate hypothermia. The head-down tilt position thus does not require special perioperative thermal precautions or management unless the leg-up position is used

  7. Development of a new compact intraoperative magnetic resonance imaging system: concept and initial experience.

    PubMed

    Morita, Akio; Sameshima, Tetsuro; Sora, Shigeo; Kimura, Toshikazu; Nishimura, Kengo; Itoh, Hirotaka; Shibahashi, Keita; Shono, Naoyuki; Machida, Toru; Hara, Naoko; Mikami, Nozomi; Harihara, Yasushi; Kawate, Ryoichi; Ochiai, Chikayuki; Wang, Weimin; Oguro, Toshiki

    2014-06-01

    Magnetic resonance imaging (MRI) during surgery has been shown to improve surgical outcomes, but the current intraoperative MRI systems are too large to install in standard operating suites. Although 1 compact system is available, its imaging quality is not ideal. We developed a new compact intraoperative MRI system and evaluated its use for safety and efficacy. This new system has a magnetic gantry: a permanent magnet of 0.23 T and an interpolar distance of 32 cm. The gantry system weighs 2.8 tons and the 5-G line is within the circle of 2.6 m. We created a new field-of-view head coil and a canopy-style radiofrequency shield for this system. A clinical trial was initiated, and the system has been used in 44 patients. This system is significantly smaller than previous intraoperative MRI systems. High-quality T2 images could discriminate tumor from normal brain tissue and identify anatomic landmarks for accurate surgery. The average imaging time was 45.5 minutes, and no clinical complications or MRI system failures occurred. Floating organisms or particles were minimal (1/200 L maximum). This intraoperative, compact, low-magnetic-field MRI system can be installed in standard operating suites to provide relatively high-quality images without sacrificing safety. We believe that such a system facilitates the introduction of the intraoperative MRI.

  8. Simulation-based education with deliberate practice may improve intraoperative handoff skills: a pilot study.

    PubMed

    Pukenas, Erin W; Dodson, Gregory; Deal, Edward R; Gratz, Irwin; Allen, Elaine; Burden, Amanda R

    2014-11-01

    To examine the results of simulation-based education with deliberate practice on the acquisition of handoff skills by studying resident intraoperative handoff communication performances. Preinvention and postintervention pilot study. Simulated operating room of a university-affiliated hospital. Resident handoff performances during 27 encounters simulating elective surgery were studied. Ten residents (CA-1, CA-2, and CA-3) participated in a one-day simulation-based handoff course. Each resident repeated simulated handoffs to deliberately practice with an intraoperative handoff checklist. One year later, 7 of the 10 residents participated in simulated intraoperative handoffs. All handoffs were videotaped and later scored for accuracy by trained raters. A handoff assessment tool was used to characterize the type and frequency of communication failures. The percentage of handoff errors and omissions were compared before simulation and postsimulation-based education with deliberate practice and at one year following the course. Initially, the overall communication failure rate, defined as the percentage of handoff omissions plus errors, was 29.7%. After deliberate practice with the intraoperative handoff checklist, the communication failure rate decreased to 16.8%, and decreased further to 13.2% one year after the course. Simulation-based education using deliberate practice may result in improved intraoperative handoff communication and retention of skills at one year. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Intraoperative implant rod three-dimensional geometry measured by dual camera system during scoliosis surgery.

    PubMed

    Salmingo, Remel Alingalan; Tadano, Shigeru; Abe, Yuichiro; Ito, Manabu

    2016-05-12

    Treatment for severe scoliosis is usually attained when the scoliotic spine is deformed and fixed by implant rods. Investigation of the intraoperative changes of implant rod shape in three-dimensions is necessary to understand the biomechanics of scoliosis correction, establish consensus of the treatment, and achieve the optimal outcome. The objective of this study was to measure the intraoperative three-dimensional geometry and deformation of implant rod during scoliosis corrective surgery.A pair of images was obtained intraoperatively by the dual camera system before rotation and after rotation of rods during scoliosis surgery. The three-dimensional implant rod geometry before implantation was measured directly by the surgeon and after surgery using a CT scanner. The images of rods were reconstructed in three-dimensions using quintic polynomial functions. The implant rod deformation was evaluated using the angle between the two three-dimensional tangent vectors measured at the ends of the implant rod.The implant rods at the concave side were significantly deformed during surgery. The highest rod deformation was found after the rotation of rods. The implant curvature regained after the surgical treatment.Careful intraoperative rod maneuver is important to achieve a safe clinical outcome because the intraoperative forces could be higher than the postoperative forces. Continuous scoliosis correction was observed as indicated by the regain of the implant rod curvature after surgery.

  10. Accuracy of Intraoperative Computed Tomography during Deep Brain Stimulation Procedures: Comparison with Postoperative Magnetic Resonance Imaging

    PubMed Central

    Bot, Maarten; van den Munckhof, Pepijn; Bakay, Roy; Stebbins, Glenn; Verhagen Metman, Leo

    2017-01-01

    Objective To determine the accuracy of intraoperative computed tomography (iCT) in localizing deep brain stimulation (DBS) electrodes by comparing this modality with postoperative magnetic resonance imaging (MRI). Background Optimal lead placement is a critical factor for the outcome of DBS procedures and preferably confirmed during surgery. iCT offers 3-dimensional verification of both microelectrode and lead location during DBS surgery. However, accurate electrode representation on iCT has not been extensively studied. Methods DBS surgery was performed using the Leksell stereotactic G frame. Stereotactic coordinates of 52 DBS leads were determined on both iCT and postoperative MRI and compared with intended final target coordinates. The resulting absolute differences in X (medial-lateral), Y (anterior-posterior), and Z (dorsal-ventral) coordinates (ΔX, ΔY, and ΔZ) for both modalities were then used to calculate the euclidean distance. Results Euclidean distances were 2.7 ± 1.1 and 2.5 ± 1.2 mm for MRI and iCT, respectively (p = 0.2). Conclusion Postoperative MRI and iCT show equivalent DBS lead representation. Intraoperative localization of both microelectrode and DBS lead in stereotactic space enables direct adjustments. Verification of lead placement with postoperative MRI, considered to be the gold standard, is unnecessary. PMID:28601874

  11. Accuracy of Intraoperative Computed Tomography during Deep Brain Stimulation Procedures: Comparison with Postoperative Magnetic Resonance Imaging.

    PubMed

    Bot, Maarten; van den Munckhof, Pepijn; Bakay, Roy; Stebbins, Glenn; Verhagen Metman, Leo

    2017-01-01

    To determine the accuracy of intraoperative computed tomography (iCT) in localizing deep brain stimulation (DBS) electrodes by comparing this modality with postoperative magnetic resonance imaging (MRI). Optimal lead placement is a critical factor for the outcome of DBS procedures and preferably confirmed during surgery. iCT offers 3-dimensional verification of both microelectrode and lead location during DBS surgery. However, accurate electrode representation on iCT has not been extensively studied. DBS surgery was performed using the Leksell stereotactic G frame. Stereotactic coordinates of 52 DBS leads were determined on both iCT and postoperative MRI and compared with intended final target coordinates. The resulting absolute differences in X (medial-lateral), Y (anterior-posterior), and Z (dorsal-ventral) coordinates (ΔX, ΔY, and ΔZ) for both modalities were then used to calculate the euclidean distance. Euclidean distances were 2.7 ± 1.1 and 2.5 ± 1.2 mm for MRI and iCT, respectively (p = 0.2). Postoperative MRI and iCT show equivalent DBS lead representation. Intraoperative localization of both microelectrode and DBS lead in stereotactic space enables direct adjustments. Verification of lead placement with postoperative MRI, considered to be the gold standard, is unnecessary. © 2017 The Author(s) Published by S. Karger AG, Basel.

  12. Genomic analysis reveals secondary glioblastoma after radiotherapy in a subset of recurrent medulloblastomas.

    PubMed

    Phi, Ji Hoon; Park, Ae Kyung; Lee, Semin; Choi, Seung Ah; Baek, In-Pyo; Kim, Pora; Kim, Eun-Hye; Park, Hee Chul; Kim, Byung Chul; Bhak, Jong; Park, Sung-Hye; Lee, Ji Yeoun; Wang, Kyu-Chang; Kim, Dong-Seok; Shim, Kyu Won; Kim, Se Hoon; Kim, Chae-Yong; Kim, Seung-Ki

    2018-06-01

    Despite great advances in understanding of molecular pathogenesis and achievement of a high cure rate in medulloblastoma, recurrent medulloblastomas are still dismal. Additionally, misidentification of secondary malignancies due to histological ambiguity leads to misdiagnosis and eventually to inappropriate treatment. Nevertheless, the genomic characteristics of recurrent medulloblastomas are poorly understood, largely due to a lack of matched primary and recurrent tumor tissues. We performed a genomic analysis of recurrent tumors from 17 pediatric medulloblastoma patients. Whole transcriptome sequencing revealed that a subset of recurrent tumors initially diagnosed as locally recurrent medulloblastomas are secondary glioblastomas after radiotherapy, showing high similarity to the non-G-CIMP proneural subtype of glioblastoma. Further analysis, including whole exome sequencing, revealed missense mutations or complex gene fusion events in PDGFRA with augmented expression in the secondary glioblastomas after radiotherapy, implicating PDGFRA as a putative driver in the development of secondary glioblastomas after treatment exposure. This result provides insight into the possible application of PDGFRA-targeted therapy in these second malignancies. Furthermore, genomic alterations of TP53 including 17p loss or germline/somatic mutations were also found in most of the secondary glioblastomas after radiotherapy, indicating a crucial role of TP53 alteration in the process. On the other hand, analysis of recurrent medulloblastomas revealed that the most prevalent alterations are the loss of 17p region including TP53 and gain of 7q region containing EZH2 which already exist in primary tumors. The 7q gain events are frequently accompanied by high expression levels of EZH2 in both primary and recurrent medulloblastomas, which provides a clue to a new therapeutic target to prevent recurrence. Considering the fact that it is often challenging to differentiate between recurrent

  13. Potential of mobile intraoperative radiotherapy technology.

    PubMed

    Goer, Donald A; Musslewhite, Chapple W; Jablons, David M

    2003-10-01

    Mobile IORT units have the potential to change the way patients who have cancer are treated. The integration of IORT into cancer treatment programs, made possible by the new technologies of mobile linear accelerators that can be used in unshielded operating rooms, makes IORT significantly less time-consuming, less costly, and less risky to administer. It is now practical for IORT to be used in early-stage disease, in addition to advanced disease, and in sites for which patient transportation in the middle of surgery is considered too risky. Preliminary results of trials for early-stage breast and rectal cancer indicate benefits of IORT. Pediatric patients and patients who have lung cancer, previously underserved by IORT therapies, can be offered potential gains when patient transport issues do not limit IORT. Furthermore, because many of these mobile systems require no shielding, it is now practical for mobile units to be shared between hospitals, making this new mobile technology much more widely available.

  14. Patient specific quality control for Stereotactic Ablative Body Radiotherapy (SABR): it takes more than one phantom

    NASA Astrophysics Data System (ADS)

    Kron, T.; Ungureanu, E.; Antony, R.; Hardcastle, N.; Clements, N.; Ukath, J.; Fox, C.; Lonski, P.; Wanigaratne, D.; Haworth, A.

    2017-01-01

    Stereotactic Ablative Body Radiotherapy (SABR) is an extension of the concepts of Stereotactic Radiosurgery from intracranial procedures to extracranial targets. This brings with it new technological challenges for set-up of a SABR program and continuing quality assurance. Compared with intracranial procedures SABR requires consideration of motion and inhomogeneities and has to deal with a much larger variety of targets ranging from lung to liver, kidney and bone. To meet many of the challenges virtually all advances in modern radiotherapy, such as Intensity Modulated and Image Guided Radiation Therapy (IMRT and IGRT) are used. Considering the few fractions and high doses per fraction delivered to complex targets it is not surprising that patient specific quality control is considered essential for safe delivery. Given the variety of targets and clinical scenarios we employ different strategies for different patients to ensure that the most important aspects of the treatment are appropriately tested, be it steep dose gradients, inhomogeneities or the delivery of dose in the presence of motion. The current paper reviews the different approaches and phantoms utilised at Peter MacCallum Cancer Centre for SABR QA.

  15. Five-year follow-up using a prostate stent as fiducial in image-guided radiotherapy of prostate cancer.

    PubMed

    Carl, Jesper; Sander, Lotte

    2015-06-01

    To report results from the five-year follow-up on a previously reported study using image-guided radiotherapy (IGRT) of localized or locally advanced prostate cancer (PC) and a removable prostate stent as fiducial. Patients with local or locally advanced PC were treated using five-field 3D conformal radiotherapy (3DRT). The clinical target volumes (CTV) were treated to 78 Gy in 39 fractions using daily on-line image guidance (IG). Late genito-urinary (GU) and gastro-intestinal (GI) toxicities were scored using the radiotherapy oncology group (RTOG) score and the common toxicity score of adverse events (CTC) score. Urinary symptoms were also scored using the international prostate symptom score (IPSS). Median observation time was 5.4 year. Sixty-two of the 90 patients from the original study cohort were eligible for toxicity assessment. Overall survival, cancer-specific survival and biochemical freedom from failure were 85%, 96% and 80%, respectively at five years after radiotherapy. Late toxicity GU and GI RTOG scores≥2 were 5% and 0%. Comparing pre- and post-radiotherapy IPSS scores indicate that development in urinary symptoms after radiotherapy may be complex. Prostate image-guided radiotherapy using a prostate stent demonstrated survival data comparable with recently published data. GU and GI toxicities at five-year follow-up were low and comparable to the lowest toxicity rates reported. These findings support that the precision of the prostate stent technique is at least as good as other techniques. IPSS revealed a complex development in urinary symptoms after radiotherapy.

  16. Intraoperative echocardiography of a dislodged Björk-Shiley mitral valve disc.

    PubMed

    Tanaka, M; Abe, T; Takeuchi, E; Watanabe, T; Tamaki, S

    1991-02-01

    The successful management of a patient who suffered an outlet strut fracture of a Björk-Shiley 60-degree convexo-concave mitral valve prosthesis is reported. Emergency operation was life-saving. Preoperative echocardiography assisted in making a prompt diagnosis, and intraoperative echocardiography allowed the detection and removal of the dislodged disc from the left ventricle at the time of the operation. The role of intraoperative echocardiography in the diagnosis of prosthetic strut fracture is emphasized.

  17. Hybrid adaptive radiotherapy with on-line MRI in cervix cancer IMRT.

    PubMed

    Oh, Seungjong; Stewart, James; Moseley, Joanne; Kelly, Valerie; Lim, Karen; Xie, Jason; Fyles, Anthony; Brock, Kristy K; Lundin, Anna; Rehbinder, Henrik; Milosevic, Michael; Jaffray, David; Cho, Young-Bin

    2014-02-01

    Substantial organ motion and tumor shrinkage occur during radiotherapy for cervix cancer. IMRT planning studies have shown that the quality of radiation delivery is influenced by these anatomical changes, therefore the adaptation of treatment plans may be warranted. Image guidance with off-line replanning, i.e. hybrid-adaptation, is recognized as one of the most practical adaptation strategies. In this study, we investigated the effects of soft tissue image guidance using on-line MR while varying the frequency of off-line replanning on the adaptation of cervix IMRT. 33 cervical cancer patients underwent planning and weekly pelvic MRI scans during radiotherapy. 5 patients of 33 were identified in a previous retrospective adaptive planning study, in which the coverage of gross tumor volume/clinical target volume (GTV/CTV) was not acceptable given single off-line IMRT replan using a 3mm PTV margin with bone matching. These 5 patients and a randomly selected 10 patients from the remaining 28 patients, a total of 15 patients of 33, were considered in this study. Two matching methods for image guidance (bone to bone and soft tissue to dose matrix) and three frequencies of off-line replanning (none, single, and weekly) were simulated and compared with respect to target coverage (cervix, GTV, lower uterus, parametrium, upper vagina, tumor related CTV and elective lymph node CTV) and OAR sparing (bladder, bowel, rectum, and sigmoid). Cost (total process time) and benefit (target coverage) were analyzed for comparison. Hybrid adaptation (image guidance with off-line replanning) significantly enhanced target coverage for both 5 difficult and 10 standard cases. Concerning image guidance, bone matching was short of delivering enough doses for 5 difficult cases even with a weekly off-line replan. Soft tissue image guidance proved successful for all cases except one when single or more frequent replans were utilized in the difficult cases. Cost and benefit analysis preferred

  18. Intraoperative panoramic image using alignment grid, is it accurate?

    PubMed

    Apivatthakakul, T; Duanghakrung, M; Luevitoonvechkit, S; Patumasutra, S

    2013-07-01

    Minimally invasive orthopedic trauma surgery relies heavily on intraoperative fluoroscopic images to evaluate the quality of fracture reduction and fixation. However, fluoroscopic images have a narrow field of view and often cannot visualize the entire long bone axis. To compare the coronal femoral alignment between conventional X-rays to that achieved with a new method of acquiring a panoramic intraoperative image. Twenty-four cadaveric femurs with simple diaphyseal fractures were fixed with an angulated broad DCP to create coronal plane malalignment. An intraoperative alignment grid was used to help stitch different fluoroscopic images together to produce a panoramic image. A conventional X-ray of the entire femur was then performed. The coronal plane angulation in the panoramic images was then compared to the conventional X-rays using a Wilcoxon signed rank test. The mean angle measured from the panoramic view was 173.9° (range 169.3°-178.0°) with median of 173.2°. The mean angle measured from the conventional X-ray was 173.4° (range 167.7°-178.7°) with a median angle of 173.5°. There was no significant difference between both methods of measurement (P = 0.48). Panoramic images produced by stitching fluoroscopic images together with help of an alignment grid demonstrated the same accuracy at evaluating the coronal plane alignment of femur fractures as conventional X-rays.

  19. An Analysis of the Utility of Handheld PET Probes for the Intraoperative Localization of Malignant Tissue

    PubMed Central

    González, Segundo Jaime; González, Lorena; Wong, Joyce; Brader, Peter; Zakowski, Maureen; Gönen, Mithat; Daghighian, Farhad; Fong, Yuman

    2012-01-01

    Introduction The intraoperative localization of suspicious lesions detected by positron emission tomography (PET) scan remains a challenge. To solve this, two novel probes have been created to accurately detect the 18F-FDG radiotracer intraoperatively. Methods Nude rats were inoculated with mesothelioma. When PET scans detected 10-mm tumors, animals were dissected and the PET probes analyzed the intraoperative radiotracer uptake of these lesions as tumor to background ratio (TBR). Results The 17 suspicious lesions seen on PET scan were localized intraoperatively (by their high TBR) using the PET probes and found malignant on pathology. Interestingly, smaller tumors not visualized on PET scan were detected intraoperatively by their high TBR and found malignant on pathology. Furthermore, using a TBR threshold as low as 2.0, both gamma (sensitivity, 100%; specificity, 80%; positive predictive value (PPV), 96%; and negative predictive value (NPV), 100%) and beta (sensitivity, 100%; specificity, 60%; PPV, 93%; and NPV, 100%) probes reliably detected suspicious lesions on PET scan imaging. They also showed an excellent area under the curve of 0.9 and 0.97 (95% CI of 0.81–0.99 and 0.93–1.0) for gamma and beta probes, respectively, in the receiver operating characteristic analysis for detecting malignancy. Conclusion This novel tool could be used synergistically with a PET scan imaging to maximize tissue selection intraoperatively. PMID:21108016

  20. Preoperative planning and intraoperative technique for accurate realignment of the Dwyer calcaneal osteotomy.

    PubMed

    Lamm, Bradley M; Gesheff, Martin G; Salton, Heather L; Dupuis, Travis W; Zeni, Ferras

    2012-01-01

    The Dwyer calcaneal osteotomy is an effective procedure for the correction of calcaneal varus deformity. However, no intraoperative method has been described to determine the amount of bone resection. We describe a simple intraoperative method for assuring accurate bone resection and measure the realignment effects of the Dwyer calcaneal osteotomy. We also review radiographic outcomes associated with 20 Dwyer calcaneal osteotomies (in 17 patients) using the intraoperative realignment technique described in this report. Preoperative and postoperative radiographs at a mean of 2.5 (range 1.5 to 5) years taken after Dwyer osteotomy were measured and compared, which revealed a mean reduction in calcaneal varus of 18° (range 2° to 36°) (p < .001), a mean decrease in the calcaneal inclination angle of 5° (range -40° to 7°) (p < .05), a mean decrease in medial calcaneal translation of 10 (range 0 to 18) mm (p < .001) relative to the tibia, and a mean dorsal translation of 2 (range 0 to 7) mm (p = .002). In an effort to attempt to structurally realign the calcaneus to a more rectus alignment, by means of Dwyer osteotomy, we recommend the use of the intraoperative bone wedge resection technique described in this report. Our experience with the patients described in this report demonstrates the usefulness of the intraoperative method that we describe in order to accurately restore the axial tibial and calcaneal relationship. Copyright © 2012 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  1. The effect of preoperative Lugol's iodine on intraoperative bleeding in patients with hyperthyroidism.

    PubMed

    Yilmaz, Yeliz; Kamer, Kemal Erdinc; Ureyen, Orhan; Sari, Erdem; Acar, Turan; Karahalli, Onder

    2016-08-01

    To investigate the effect of preoperative Lugol's iodine on intraoperative bleeding in patients with hyperthyroidism. This controlled, randomized, prospective cohort was carried out on 40 patients who admitted for surgery due to hyperthyroidism. Cases were randomly assigned to receive either preoperative treatment with Lugol solution (Group 1) or no preoperative treatment with Lugol solution (Group 2). Group 3 (n = 10) consisted of healthy adults with no known history and signs of hyperthyroidism. Blood flow through the thyroid arteries of patients was measured by color flow Doppler ultrasonography. Free T3, free T4, TSH, thyroid volume and the resistance index of the four main thyroid arteries were measured in all patients. There was not a significant difference between gender, preoperative serum thyroid hormone levels, or thyroid gland volumes between groups 1 and 2. The mean blood flow of the patients in Group 1 was significantly lower than values in Group 2. When age, gender, thyroid hormone, TSH, thyroid volume, blood flow, and Lugol solution treatment were included as independent variables, Lugol solution treatment (OR, 7.40; 95% CI, 1.02-58.46; p = 0.001) was found to be the only significant independent determinant of intraoperative blood loss. Lugol solution treatment resulted in a 7.40-fold decrease in the rate of intraoperative blood loss. Preoperative Lugol solution treatment was found to be a significant independent determinant of intraoperative blood loss. Moreover, preoperative Lugol solution treatment decreased the rate of blood flow, and intraoperative blood loss during thyroidectomy.

  2. Intraoperative colon mucosal oxygen saturation during aortic surgery.

    PubMed

    Lee, Eugene S; Bass, Arie; Arko, Frank R; Heikkinen, Maarit; Harris, E John; Zarins, Christopher K; van der Starre, Pieter; Olcott, Cornelius

    2006-11-01

    Colonic ischemia after aortic reconstruction is a devastating complication with high mortality rates. This study evaluates whether Colon Mucosal Oxygen Saturation (CMOS) correlates with colon ischemia during aortic surgery. Aortic reconstruction was performed in 25 patients, using a spectrophotometer probe that was inserted in each patient's rectum before the surgical procedure. Continuous CMOS, buccal mucosal oxygen saturation, systemic mean arterial pressure, heart rate, pulse oximetry, and pivotal intra-operative events were collected. Endovascular aneurysm repair (EVAR) was performed in 20 and open repair in 5 patients with a mean age of 75 +/- 10 (+/-SE) years. CMOS reliably decreased in EVAR from a baseline of 56% +/- 8% to 26 +/- 17% (P < 0.0001) during infrarenal aortic balloon occlusion and femoral arterial sheath placement. CMOS similarly decreased during open repair from 56% +/- 9% to 15 +/- 19% (P < 0.0001) when the infrarenal aorta and iliac arteries were clamped. When aortic circulation was restored in both EVAR and open surgery, CMOS returned to baseline values 56.5 +/- 10% (P = 0.81). Mean recovery time in CMOS after an aortic intervention was 6.4 +/- 3.3 min. Simultaneous buccal mucosal oxygen saturation was stable (82% +/- 6%) during aortic manipulation but would fall significantly during active bleeding. There were no device related CMOS measurement complications. Intra-operative CMOS is a sensitive measure of colon ischemia where intraoperative events correlated well with changes in mucosal oxygen saturation. Transient changes demonstrate no problem. However, persistently low CMOS suggests colon ischemia, thus providing an opportunity to revascularize the inferior mesenteric artery or hypogastric arteries to prevent colon infarction.

  3. Support surfaces for intraoperative prevention of pressure ulcers in patients undergoing surgery: a cost-effectiveness analysis.

    PubMed

    Pham, Ba'; Teague, Laura; Mahoney, James; Goodman, Laurie; Paulden, Mike; Poss, Jeff; Li, Jianli; Sikich, Nancy Joan; Lourenco, Rosemarie; Ieraci, Luciano; Carcone, Steven; Krahn, Murray

    2011-07-01

    Patients who undergo prolonged surgical procedures are at risk of developing pressure ulcers. Recent systematic reviews suggest that pressure redistribution overlays on operating tables significantly decrease the associated risk. Little is known about the cost effectiveness of using these overlays in a prevention program for surgical patients. Using a Markov cohort model, we evaluated the cost effectiveness of an intraoperative prevention strategy with operating table overlays made of dry, viscoelastic polymer from the perspective of a health care payer over a 1-year period. We simulated patients undergoing scheduled surgical procedures lasting ≥90 min in the supine or lithotomy position. Compared with the current practice of using standard mattresses on operating tables, the intraoperative prevention strategy decreased the estimated intraoperative incidence of pressure ulcers by 0.51%, corresponding to a number-needed-to-treat of 196 patients. The average cost of using the operating table overlay was $1.66 per patient. Compared with current practice, this intraoperative prevention strategy would increase slightly the quality-adjusted life days of patients and by decreasing the incidence of pressure ulcers, this strategy would decrease both hospital and home care costs for treating fewer pressure ulcers originated intraoperatively. The cost savings was $46 per patient, which ranged from $13 to $116 by different surgical populations. Intraoperative prevention was 99% likely to be more cost effective than the current practice. In patients who undergo scheduled surgical procedures lasting ≥90 min, this intraoperative prevention strategy could improve patients' health and save hospital costs. The clinical and economic evidence support the implementation of this prevention strategy in settings where it has yet to become current practice. Copyright © 2011 Mosby, Inc. All rights reserved.

  4. Melatonin prevents possible radiotherapy-induced thyroid injury.

    PubMed

    Arıcıgil, Mitat; Dündar, Mehmet Akif; Yücel, Abitter; Eryılmaz, Mehmet Akif; Aktan, Meryem; Alan, Mehmet Akif; Fındık, Sıdıka; Kılınç, İbrahim

    2017-12-01

    We aimed to investigate the protective effect of melatonin in radiotherapy-induced thyroid gland injury in an experimental rat model. Thirty-two rats were divided into four groups: the control group, melatonin treatment group, radiotherapy group and melatonin plus radiotherapy group. The neck region of each rat was defined by simulation and radiated with 2 Gray (Gy) per min with 6-MV photon beams, for a total dose of 18 Gy. Melatonin was administered at a dose of 50 mg/kg through intraperitoneal injection, 15 min prior to radiation exposure. Thirty days after the beginning of the study, rats were decapitated and analyses of blood and thyroid tissue were performed. Tumor necrosis factor-α (TNF-α), interleukin-1 beta (IL-1β), thiobarbituric acid reactive substances (TBARS) and nitric oxide (NO) levels in the radiotherapy group were significantly higher than those in the melatonin plus radiotherapy group (p < .05), whereas interleukin-10 (IL-10) and glutathione (GSH) values were higher in the melatonin plus radiotherapy group (p < .05). The infiltration of inflammatory cells and percentage of apoptosis in the radiotherapy group were significantly higher than those in the melatonin plus radiotherapy group (p < .05). Melatonin helped protect thyroid gland structure against the undesired cytotoxic effects of radiotherapy in rats.

  5. Reliability of intraoperative neurophysiological monitoring using motor evoked potentials during resection of metastases in motor-eloquent brain regions: clinical article.

    PubMed

    Krieg, Sandro M; Schäffner, Michael; Shiban, Ehab; Droese, Doris; Obermüller, Thomas; Gempt, Jens; Meyer, Bernhard; Ringel, Florian

    2013-06-01

    Resection of gliomas in or adjacent to the motor system is widely performed using intraoperative neuromonitoring (IOM). For resection of cerebral metastases in motor-eloquent regions, however, data are sparse and IOM in such cases is not yet widely described. Since recent studies have shown that cerebral metastases infiltrate surrounding brain tissue, this study was undertaken to assess the value and influence of IOM during resection of supratentorial metastases in motor-eloquent regions. Between 2006 and 2011, the authors resected 206 consecutive supratentorial metastases, including 56 in eloquent motor areas with monitoring of monopolar direct cortically stimulated motor evoked potentials (MEPs). The authors evaluated the relationship between the monitoring data and the course of surgery, clinical data, and postoperative imaging. Motor evoked potential monitoring was successful in 53 cases (93%). Reduction of MEP amplitude correlated better with postoperative outcomes when the threshold for significant amplitude reduction was set at 80% (only > 80% reduction was considered significant decline) than when it was set at 50% (> 50% amplitude reduction was considered significant decline). Evidence of residual tumor was seen on MR images in 28% of the cases with significant MEP reduction. No residual tumor was seen in any case of stable MEP monitoring. Moreover, preoperative motor deficit, recursive partitioning analysis Class 3, and preoperative radiotherapy were independent risk factors for a new surgery-related motor weakness (occurring in 64% of patients with and 11% of patients without radiotherapy, p > 0.01). Continuous MEP monitoring provides reliable monitoring of the motor system and also influences the course of operation in resection of cerebral metastases. However, in establishing warning criteria, only an amplitude decline > 80% of the baseline should be considered significant.

  6. Examining Determinants of Radiotherapy Access: Do Cost and Radiotherapy Inconvenience Affect Uptake of Breast-conserving Treatment for Early Breast Cancer?

    PubMed

    Lam, J; Cook, T; Foster, S; Poon, R; Milross, C; Sundaresan, P

    2015-08-01

    Radiotherapy utilisation is likely affected by multiple factors pertaining to radiotherapy access. Radiotherapy is an integral component of breast-conserving treatment (BCT) for early breast cancer. We aimed to determine if stepwise improvements in radiotherapy access in regional Australia affected the uptake of BCT and thus radiotherapy. Breast cancer operations in the Central Coast of New South Wales between January 2010 and March 2014 for T1-2N0-1M0 invasive or in situ (≤5 cm) disease in female patients eligible for BCT were examined. BCT uptake was calculated for three 1 year periods: period 1 (local radiotherapy available at cost to user or out of area radiotherapy with travel cost and inconvenience); period 2 (as per period 1 + publicly funded transport and radiotherapy at out of area facilities at no cost to user); period 3 (as per period 1 + publicly funded local radiotherapy at no cost to user). In total, 574 cases met eligibility criteria. BCT declined with increasing distance to publicly funded radiotherapy (P = 0.035). BCT rates for periods 1, 2 and 3 were 63% (113/180), 61% (105/173) and 71% (156/221). There were no statistically significant differences in BCT between periods 1 and 2 in the whole cohort or within age, histology or tumour size subgroups. Overall, there was a 9% increase in BCT in the whole cohort in period 3 compared with periods 1 and 2 (P = 0.031). This increase was statistically significant for women over 70 years (19% increase, P = 0.034), for women with ductal carcinoma in situ (25% increase, P = 0.013) and for women with primary tumours that were ≤10 mm (21% increase, P = 0.016). Improving the affordability of radiotherapy through publicly funded transport and radiotherapy at out of area facilities did not improve BCT uptake in a region where radiotherapy was locally available, albeit at cost to the user. Improving both affordability and convenience through the provision of local publicly funded radiotherapy increased BCT

  7. Intraoperative probe detecting β- decays in brain tumour radio-guided surgery

    NASA Astrophysics Data System (ADS)

    Solfaroli Camillocci, E.; Bocci, V.; Chiodi, G.; Collamati, F.; Donnarumma, R.; Faccini, R.; Mancini Terracciano, C.; Marafini, M.; Mattei, I.; Muraro, S.; Recchia, L.; Rucinski, A.; Russomando, A.; Toppi, M.; Traini, G.; Morganti, S.

    2017-02-01

    Radio-guided surgery (RGS) is a technique to intraoperatively detect tumour remnants, favouring a radical resection. Exploiting β- emitting tracers provides a higher signal to background ratio compared to the established technique with γ radiation, allowing the extension of the RGS applicability range. We developed and tested a detector based on para-terphenyl scintillator with high sensitivity to low energy electrons and almost transparent to γs to be used as intraoperative probe for RGS with β- emitting tracer. Portable read out electronics was customised to match the surgeon needs. This probe was used for preclinical test on specific phantoms and a test on "ex vivo" specimens from patients affected by meningioma showing very promising results for the application of this new technique on brain tumours. In this paper, the prototype of the intraoperative probe and the tests are discussed; then, the results on meningioma are used to make predictions on the performance of the probe detecting residuals of a more challenging and more interesting brain tumour: the glioma.

  8. Aortic balloon occlusion for controlling intraoperative hemorrhage in patients with placenta previa increta/percreta.

    PubMed

    Wang, Ying-Lan; Su, Fang-Ming; Zhang, Hai-Ying; Wang, Fang; Zhe, Rui-Lian; Shen, Xin-Ying

    2017-11-01

    To investigate whether abdominal aortic balloon occlusion (ABO) effectively reduces intraoperative hemorrhage in patents with placenta previa increta/increta. Forty-three women were diagnosed as placenta previa increta/percreta by ultrasound and MRI. These patients' assessments were taken by their chief physician, and they were under necessity of previous cesarean section as confirmed by the committee of experts during consultation. There was no significant difference in disease risk rating between them in whole process. Although our department provided a more appropriate method, 10 of 43 patients chose intraoperative aortic balloon occlusion (IABO). Other 33 patients who refused that suggestion were considered as control group. Fully informed consents were obtained from all patients in this study group. The intraoperative blood loss, blood transfusion, rate of hysterectomy and complications of mothers and fetus of IABO group and control group were analyzed. The median intraoperative blood loss was 1000 ml in the IABO group compared with 2000 ml in the control group (p < 0.05). The median volume of transfused red blood cells was 1100 ml in the IABO group compared with 2000 ml in the control group (p < 0.05). 33.3% (11/33) patients in the control group had hemorrhagic shock, and one of them suffered from cardiac arrest intraoperatively because of severe bleeding. However, none of these serious events occurred in the IABO group (p < 0.05). The hysterectomy rate was 70% (7/10) in the IABO group and 63.3% (21/33) in the control group (p > 0.05). No IABO-related complications were observed in the mother and fetus. IABO is an effective and safe method to control intraoperative blood loss and blood transfusion in patients with placenta previa increta/percreta.

  9. Decreasing Temporal Lobe Dose With Five-Field Intensity-Modulated Radiotherapy for Treatment of Pituitary Macroadenomas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parhar, Preeti K.; Duckworth, Tamara; Shah, Parinda

    2010-10-01

    Purpose: To compare temporal lobe dose delivered by three pituitary macroadenoma irradiation techniques: three-field three-dimensional conformal radiotherapy (3D-CRT), three-field intensity-modulated radiotherapy (3F IMRT), and a proposed novel alternative of five-field IMRT (5F IMRT). Methods and Materials: Computed tomography-based external beam radiotherapy planning was performed for 15 pituitary macroadenoma patients treated at New York University between 2002 and 2007 using: 3D-CRT (two lateral, one midline superior anterior oblique [SAO] beams), 3F IMRT (same beam angles), and 5F IMRT (same beam angles with additional right SAO and left SAO beams). Prescription dose was 45 Gy. Target volumes were: gross tumor volume (GTV)more » = macroadenoma, clinical target volume (CTV) = GTV, and planning target volume = CTV + 0.5 cm. Structure contouring was performed by two radiation oncologists guided by an expert neuroradiologist. Results: Five-field IMRT yielded significantly decreased temporal lobe dose delivery compared with 3D-CRT and 3F IMRT. Temporal lobe sparing with 5F IMRT was most pronounced at intermediate doses: mean V25Gy (% of total temporal lobe volume receiving {>=}25 Gy) of 13% vs. 28% vs. 29% for right temporal lobe and 14% vs. 29% vs. 30% for left temporal lobe for 5F IMRT, 3D-CRT, and 3F IMRT, respectively (p < 10{sup -7} for 5F IMRT vs. 3D-CRT and 5F IMRT vs. 3F IMRT). Five-field IMRT plans did not compromise target coverage, exceed normal tissue dose constraints, or increase estimated brain integral dose. Conclusions: Five-field IMRT irradiation technique results in a statistically significant decrease in the dose to the temporal lobes and may thus help prevent neurocognitive sequelae in irradiated pituitary macroadenoma patients.« less

  10. Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System

    PubMed Central

    Court, Laurence E.; Kisling, Kelly; McCarroll, Rachel; Zhang, Lifei; Yang, Jinzhong; Simonds, Hannah; du Toit, Monique; Trauernicht, Chris; Burger, Hester; Parkes, Jeannette; Mejia, Mike; Bojador, Maureen; Balter, Peter; Branco, Daniela; Steinmann, Angela; Baltz, Garrett; Gay, Skylar; Anderson, Brian; Cardenas, Carlos; Jhingran, Anuja; Shaitelman, Simona; Bogler, Oliver; Schmeller, Kathleen; Followill, David; Howell, Rebecca; Nelson, Christopher; Peterson, Christine; Beadle, Beth

    2018-01-01

    The Radiation Planning Assistant (RPA) is a system developed for the fully automated creation of radiotherapy treatment plans, including volume-modulated arc therapy (VMAT) plans for patients with head/neck cancer and 4-field box plans for patients with cervical cancer. It is a combination of specially developed in-house software that uses an application programming interface to communicate with a commercial radiotherapy treatment planning system. It also interfaces with a commercial secondary dose verification software. The necessary inputs to the system are a Treatment Plan Order, approved by the radiation oncologist, and a simulation computed tomography (CT) image, approved by the radiographer. The RPA then generates a complete radiotherapy treatment plan. For the cervical cancer treatment plans, no additional user intervention is necessary until the plan is complete. For head/neck treatment plans, after the normal tissue and some of the target structures are automatically delineated on the CT image, the radiation oncologist must review the contours, making edits if necessary. They also delineate the gross tumor volume. The RPA then completes the treatment planning process, creating a VMAT plan. Finally, the completed plan must be reviewed by qualified clinical staff. PMID:29708544

  11. Comparative Analysis of Neural Network Training Methods in Real-time Radiotherapy.

    PubMed

    Nouri, S; Hosseini Pooya, S M; Soltani Nabipour, J

    2017-03-01

    The motions of body and tumor in some regions such as chest during radiotherapy treatments are one of the major concerns protecting normal tissues against high doses. By using real-time radiotherapy technique, it is possible to increase the accuracy of delivered dose to the tumor region by means of tracing markers on the body of patients. This study evaluates the accuracy of some artificial intelligence methods including neural network and those of combination with genetic algorithm as well as particle swarm optimization (PSO) estimating tumor positions in real-time radiotherapy. One hundred recorded signals of three external markers were used as input data. The signals from 3 markers thorough 10 breathing cycles of a patient treated via a cyber-knife for a lung tumor were used as data input. Then, neural network method and its combination with genetic or PSO algorithms were applied determining the tumor locations using MATLAB© software program. The accuracies were obtained 0.8%, 12% and 14% in neural network, genetic and particle swarm optimization algorithms, respectively. The internal target volume (ITV) should be determined based on the applied neural network algorithm on training steps.

  12. Intraoperative anaphylaxis: a case report of allergy to ranitidine.

    PubMed

    Antonicelli, L; Stagnozzi, G; Massaccesi, C; Manfredi, M; Valentini, M; Campi, P

    2012-12-01

    We report the case of a 18-year old male who developed intraoperative anaphylaxis. The presence of specific IgE to ranitidine was documented This case confirms the possibility of anaphylaxis at first exposure.

  13. Quantitative assessment of biliary stent artifacts on MR images: Potential implications for target delineation in radiotherapy.

    PubMed

    Gurney-Champion, Oliver J; Bruins Slot, Thijs; Lens, Eelco; van der Horst, Astrid; Klaassen, Remy; van Laarhoven, Hanneke W M; van Tienhoven, Geertjan; van Hooft, Jeanin E; Nederveen, Aart J; Bel, Arjan

    2016-10-01

    Biliary stents may cause susceptibility artifacts, gradient-induced artifacts, and radio frequency (RF) induced artifacts on magnetic resonance images, which can hinder accurate target volume delineation in radiotherapy. In this study, the authors investigated and quantified the magnitude of these artifacts for stents of different materials. Eight biliary stents made of nitinol, platinum-cored nitinol, stainless steel, or polyethylene from seven vendors, with different lengths (57-98 mm) and diameters (3.0-11.7 mm), were placed in a phantom. To quantify the susceptibility artifacts sequence-independently, ΔB0-maps and T2 ∗ -maps were acquired at 1.5 and 3 T. To study the effect of the gradient-induced artifacts at 3 T, signal decay in images obtained with maximum readout gradient-induced artifacts was compared to signal decay in reference scans. To quantify the RF induced artifacts at 3 T, B1-maps were acquired. Finally, ΔB0-maps and T2 ∗ -maps were acquired at 3 T of two pancreatic cancer patients who had received platinum-cored nitinol biliary stents. Outside the stent, susceptibility artifacts dominated the other artifacts. The stainless steel stent produced the largest susceptibility artifacts. The other stents caused decreased T2 ∗ up to 5.1 mm (1.5 T) and 8.5 mm (3 T) from the edge of the stent. For sequences with a higher bandwidth per voxel (1.5 T: BW vox > 275 Hz/voxel; 3 T: BW vox > 500 Hz/voxel), the B0-related susceptibility artifacts were negligible (<0.2 voxels). The polyethylene stent showed no artifacts. In vivo, the changes in B0 and T2 ∗ induced by the stent were larger than typical variations in B0 and T2 ∗ induced by anatomy when the stent was at an angle of 30° with the main magnetic field. Susceptibility artifacts were dominating over the other artifacts. The magnitudes of the susceptibility artifacts were determined sequence-independently. This method allows to include additional safety margins that ensure target irradiation.

  14. Comparison of pencil beam–based homogeneous vs inhomogeneous target dose planning for stereotactic body radiotherapy of peripheral lung tumors through Monte Carlo–based recalculation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ohtakara, Kazuhiro, E-mail: ohtakara@murakami.asahi-u.ac.jp; Hoshi, Hiroaki

    2015-10-01

    This study was conducted to ascertain whether homogeneous target dose planning is suitable for stereotactic body radiotherapy (SBRT) of peripheral lung cancer under appropriate breath-holding. For 20 peripheral lung tumors, paired dynamic conformal arc plans were generated by only adjusting the leaf margin to the planning target volume (PTV) edge for fulfilling the conditions such that the prescription isodose surface (IDS) encompassing exactly 95% of the PTV (PTV D{sub 95}) corresponds to 95% and 80% IDS, normalized to 100% at the PTV isocenter under a pencil beam (PB) algorithm with radiologic path length correction. These plans were recalculated using themore » x-ray voxel Monte Carlo (XVMC) algorithm under otherwise identical conditions, and then compared. Lesions abutting the parietal pleura or not were defined as edge or island tumors, respectively, and the influences of the target volume and its location relative to the chest wall on the target dose were examined. The median (range) leaf margin required for the 95% and 80% plans was 3.9 mm (1.3 to 5.0) and −1.2 mm (−1.8 to 0.1), respectively. Notably, the latter was significantly correlated negatively with PTV. In the 80% plans, the PTV D{sub 95} was slightly higher under XVMC, whereas the PTV D{sub 98} was significantly lower, irrespective of the dose calculation algorithm used. Other PTV and all gross tumor volume doses were significantly higher, while the lung doses outside the PTV were slightly lower. The target doses increased as a function of PTV and were significantly lower for island tumors than for edge tumors. In conclusion, inhomogeneous target dose planning using smaller leaf margin for a larger tumor volume was deemed suitable in ensuring more sufficient target dose while slightly reducing lung dose. In addition, more inhomogeneous target dose planning using <80% IDS (e.g., 70%) for PTV covering would be preferable for island tumors.« less

  15. TOPICAL REVIEW: Anatomical imaging for radiotherapy

    NASA Astrophysics Data System (ADS)

    Evans, Philip M.

    2008-06-01

    The goal of radiation therapy is to achieve maximal therapeutic benefit expressed in terms of a high probability of local control of disease with minimal side effects. Physically this often equates to the delivery of a high dose of radiation to the tumour or target region whilst maintaining an acceptably low dose to other tissues, particularly those adjacent to the target. Techniques such as intensity modulated radiotherapy (IMRT), stereotactic radiosurgery and computer planned brachytherapy provide the means to calculate the radiation dose delivery to achieve the desired dose distribution. Imaging is an essential tool in all state of the art planning and delivery techniques: (i) to enable planning of the desired treatment, (ii) to verify the treatment is delivered as planned and (iii) to follow-up treatment outcome to monitor that the treatment has had the desired effect. Clinical imaging techniques can be loosely classified into anatomic methods which measure the basic physical characteristics of tissue such as their density and biological imaging techniques which measure functional characteristics such as metabolism. In this review we consider anatomical imaging techniques. Biological imaging is considered in another article. Anatomical imaging is generally used for goals (i) and (ii) above. Computed tomography (CT) has been the mainstay of anatomical treatment planning for many years, enabling some delineation of soft tissue as well as radiation attenuation estimation for dose prediction. Magnetic resonance imaging is fast becoming widespread alongside CT, enabling superior soft-tissue visualization. Traditionally scanning for treatment planning has relied on the use of a single snapshot scan. Recent years have seen the development of techniques such as 4D CT and adaptive radiotherapy (ART). In 4D CT raw data are encoded with phase information and reconstructed to yield a set of scans detailing motion through the breathing, or cardiac, cycle. In ART a set of

  16. Intraoperative linguistic performance during awake brain surgery predicts postoperative linguistic deficits.

    PubMed

    Chang, Wei-Han; Pei, Yu-Cheng; Wei, Kuo-Chen; Chao, Yi-Ping; Chen, Mei-Hui; Yeh, Heng-An; Jaw, Fu-Shan; Chen, Pin-Yuan

    2018-04-10

    Awake craniotomy pursues a balance between extensive tumor resection and preservation of postoperative language function. A dilemma exists in patients whose tumor resection is restricted due to signs of language impairment observed during awake craniotomy. In order to determine the degree to which recovery of language function caused by tumor resection can be achieved by spontaneous neuroplasticity, the change in postoperative language function was compared to quantified intraoperative linguistic performance. The modified, short-form Boston Diagnostic Aphasia Examination (sfBDAE) was used to assess pre- and postoperative language functions; visual object naming (DO 80) and semantic-association (Pyramid and Palm Tree Test, PPTT) tests assessed intraoperative linguistic performance. DO 80 and PPTT were performed alternatively during subcortical functional monitoring while performing tumor resection and sfBDAE was assessed 1-week postoperatively. Most patients with observed language impairment during awake surgery showed improved language function postoperatively. Both intraoperative DO 80 and PPTT showed significant correlation to postoperative sfBDAE domain scores (p < 0.05), with a higher correlation observed with PPTT. A linear regression model showed that only PPTT predicted the postoperative sfBDAE domain scores with the adjusted R 2 ranging from 0.51 to 0.89 (all p < 0.01). Receiver operating characteristic analysis showed a cutoff value of PPTT that yielded a sensitivity of 80% and specificity of 100%. PPTT may be a feasible tool for intraoperative linguistic evaluation that can predict postoperative language outcomes. Further studies are needed to determine the extent of tumor resection that optimizes the postoperative language following neuroplasticity.

  17. Comparison of onboard low-field magnetic resonance imaging versus onboard computed tomography for anatomy visualization in radiotherapy.

    PubMed

    Noel, Camille E; Parikh, Parag J; Spencer, Christopher R; Green, Olga L; Hu, Yanle; Mutic, Sasa; Olsen, Jeffrey R

    2015-01-01

    Onboard magnetic resonance imaging (OB-MRI) for daily localization and adaptive radiotherapy has been under development by several groups. However, no clinical studies have evaluated whether OB-MRI improves visualization of the target and organs at risk (OARs) compared to standard onboard computed tomography (OB-CT). This study compared visualization of patient anatomy on images acquired on the MRI-(60)Co ViewRay system to those acquired with OB-CT. Fourteen patients enrolled on a protocol approved by the Institutional Review Board (IRB) and undergoing image-guided radiotherapy for cancer in the thorax (n = 2), pelvis (n = 6), abdomen (n = 3) or head and neck (n = 3) were imaged with OB-MRI and OB-CT. For each of the 14 patients, the OB-MRI and OB-CT datasets were displayed side-by-side and independently reviewed by three radiation oncologists. Each physician was asked to evaluate which dataset offered better visualization of the target and OARs. A quantitative contouring study was performed on two abdominal patients to assess if OB-MRI could offer improved inter-observer segmentation agreement for adaptive planning. In total 221 OARs and 10 targets were compared for visualization on OB-MRI and OB-CT by each of the three physicians. The majority of physicians (two or more) evaluated visualization on MRI as better for 71% of structures, worse for 10% of structures, and equivalent for 14% of structures. 5% of structures were not visible on either. Physicians agreed unanimously for 74% and in majority for > 99% of structures. Targets were better visualized on MRI in 4/10 cases, and never on OB-CT. Low-field MR provides better anatomic visualization of many radiotherapy targets and most OARs as compared to OB-CT. Further studies with OB-MRI should be pursued.

  18. Intra-Operative Dosimetry in Prostate Brachytherapy

    DTIC Science & Technology

    2006-11-01

    available in most hospitals do not have encoded rotational joints , so one never knows where the fluoro shots are coming from relative to one another...seed matching. CT and MRI based techniques49,50 were also proposed, but cannot be used intraoperatively, and have poor resolution in the axial ...have encoded rotational joints , so one never knows where the fluoro shots are coming from relative to one another. We have addressed this issue by

  19. A Simulation Study of a Radiofrequency Localization System for Tracking Patient Motion in Radiotherapy.

    PubMed

    Ostyn, Mark; Kim, Siyong; Yeo, Woon-Hong

    2016-04-13

    One of the most widely used tools in cancer treatment is external beam radiotherapy. However, the major risk involved in radiotherapy is excess radiation dose to healthy tissue, exacerbated by patient motion. Here, we present a simulation study of a potential radiofrequency (RF) localization system designed to track intrafraction motion (target motion during the radiation treatment). This system includes skin-wearable RF beacons and an external tracking system. We develop an analytical model for direction of arrival measurement with radio frequencies (GHz range) for use in a localization estimate. We use a Monte Carlo simulation to investigate the relationship between a localization estimate and angular resolution of sensors (signal receivers) in a simulated room. The results indicate that the external sensor needs an angular resolution of about 0.03 degrees to achieve millimeter-level localization accuracy in a treatment room. This fundamental study of a novel RF localization system offers the groundwork to design a radiotherapy-compatible patient positioning system for active motion compensation.

  20. Experiences with an application of industrial robotics for accurate patient positioning in proton radiotherapy.

    PubMed

    Allgower, C E; Schreuder, A N; Farr, J B; Mascia, A E

    2007-03-01

    Protons beams deliver targeted radiation doses with greater precision than is possible with electrons or megavoltage X-ray photons, but to retain this advantage, patient positioning systems at proton clinics must meet tighter accuracy requirements. For this and other reasons, robots were incorporated into the treatment room systems at MPRI. The Midwest Proton Radiotherapy Institute (MPRI) is the first radiotherapy facility in the United States to use commercial robots with six degrees of freedom for patient positioning, rather than a traditional bed with four degrees of freedom. This paper outlines the ways in which robots are used at MPRI and attempts to distil insights from the experience of treating over 200 radiotherapy patients with a robotic system from February 2004 to late 2006. The system has performed well, and with great reliability, but there is room for future improvement, especially in ease of use and in reducing the time to get patients into position. Copyright 2006 John Wiley & Sons, Ltd.