Sample records for taxus drug-eluting stent

  1. Evaluation of balloon withdrawal forces with bare-metal stents, compared with Taxus and Cypher drug-eluting coronary stents: balloon, stent and polymer interactions.

    PubMed

    Turk, Marvee; Gupta, Vishal; Fischell, Tim A

    2010-03-01

    There have been reports of serious complications related to difficulty removing the deflated Taxus stent delivery balloon after stent deployment. The purpose of this study was to determine whether the Taxus SIBS polymer was "sticky" and associated with an increase in the force required to remove the stent delivery balloon after stent deployment, using a quantitative, ex-vivo model. Balloon-polymer-stent interactions during balloon withdrawal were measured with the Taxus Liberté, Liberté bare-metal stent (BMS; no polymer = control), the Cordis Cypher drug-eluting stent (DES; PEVA/PBMA polymer) and the BX Velocity (no polymer). We quantitatively measured the force required to remove the deflated stent delivery balloon from each of these stents in simulated vessels at 37 degrees C in a water bath. Balloon withdrawal forces were measured in straight (0 degree curve), mildly curved (20 degree curve) and moderately curved (40 degree curve) simulated vessel segments. The average peak force required to remove the deflated balloon catheter from the Taxus Liberté DES, the Liberté BMS, the Cypher DES, and the Bx Velocity BMS were similar in straight segments, but were much greater for the Taxus Liberté in the moderately curved segments (1.4 lbs vs. 0.11 lbs, 0.11 lbs and 0.12 lbs, respectively; p < 0.0001). The SIBS polymer of the Taxus Liberté DES appears to be "sticky" and is associated with high forces required to withdraw the deflated balloon from the deployed stent in curved segments. This withdrawal issue may help to explain the clinical complications that have been reported with this device.

  2. Stent Coating Integrity of Durable and Biodegradable Coated Drug Eluting Stents.

    PubMed

    Yazdani, Saami K; Sheehy, Alexander; Pacetti, Stephen; Rittlemeyer, Brandon; Kolodgie, Frank D; Virmani, Renu

    2016-10-01

    Coatings consisting of a polymer and drug are widely used in drug-eluting stents (DES) and are essential in providing programmable drug release kinetics. Among other factors, stent coating technologies can influence blood compatibility, affect acute and sub-acute healing, and potentially trigger a chronic inflammatory response. The aim of this study was to investigate the short-term (7 and 28 days) and long-term (90 and 180 days) coating integrity of the Xience Prime Everolimus-Eluting Stent (EES), Resolute Zotarolimus-Eluting Stent (ZES), Taxus Paclitaxel-Eluting Stent (PES), and Nobori Biolimus A9-Eluting Stent (BES) in a rabbit ilio-femoral stent model. Stented arteries (n = 48) were harvested and the tissue surrounding the implanted stents digested away with an enzymatic solution. Results demonstrated that the majority of struts of EES were without any coating defects with a few struts showing minor defects. Similarly, for the ZES, most of the struts were without coating defects at all time points except at 180 days. The majority of PES demonstrated mostly webbing and uneven coating. In the BES group, the majority of strut coating showed polymer cracking. Overall, the EES and ZES had fewer coating defects than the PES and BES. Coating defects, however increase over time for the ZES, whereas the percent of coating irregularities remained constant for the EES. These results provide, for the first time, a comparison of the long-term durability of these drug-eluting stent coatings in vivo. © 2016, Wiley Periodicals, Inc.

  3. Outcomes with the paclitaxel-eluting stent in patients with acute coronary syndromes: analysis from the TAXUS-IV trial.

    PubMed

    Moses, Jeffrey W; Mehran, Roxana; Nikolsky, Eugenia; Lasala, John M; Corey, Woodrow; Albin, Glenn; Hirsch, Cary; Leon, Martin B; Russell, Mary E; Ellis, Stephen G; Stone, Gregg W

    2005-04-19

    We sought to investigate the outcomes of paclitaxel-eluting stent implantation in patients with unstable angina or non-ST-segment elevation myocardial infarction undergoing percutaneous coronary intervention (PCI). Whether the paclitaxel-eluting stent is safe and effective in patients with acute coronary syndromes (ACS) is unknown. In the TAXUS-IV trial, 1,314 patients with stable or unstable ischemic syndromes undergoing PCI were randomized to treatment with either the slow-release, polymer-based, paclitaxel-eluting TAXUS stent or a bare-metal EXPRESS stent (Boston Scientific Corp., Natick, Massachusetts). The results were stratified by the acuity of the presenting clinical syndrome. Acute coronary syndromes were present in 450 patients (34.2%), 237 of whom were assigned to paclitaxel-eluting stents and 213 to bare-metal stents. The baseline and procedural characteristics were well matched between the groups. Clinical outcomes at 30 days were similar with both stents. At one-year follow-up, patients with ACS assigned to the paclitaxel-eluting stent compared to the control stent had strikingly lower rates of target lesion revascularization (TLR) (3.9% vs. 16.0%, p < 0.0001) and major adverse cardiac events (11.1 vs. 21.7%, p = 0.002). By multivariate analysis, ACS was an independent predictor of in-stent restenosis in the cohort treated with bare-metal stents (hazard ratio [HR] = 2.03 [95% confidence interval (CI) 1.05 to 3.92], p = 0.035), while among patients randomized to the paclitaxel-eluting stents, ACS was an independent predictor of freedom from restenosis (HR = 0.27 [95% CI 0.08 to 0.97], p = 0.04). The use of the paclitaxel-eluting TAXUS stent was safe in patients with unstable ischemic syndromes, and was associated with marked reduction of ischemia-driven TLR and adverse cardiac events at one year.

  4. Prasugrel plus aspirin beyond 12 months is associated with improved outcomes after TAXUS Liberté paclitaxel-eluting coronary stent placement.

    PubMed

    Garratt, Kirk N; Weaver, W Douglas; Jenkins, Ronald G; Pow, Thomas K; Mauri, Laura; Kereiakes, Dean J; Winters, Kenneth J; Christen, Thomas; Allocco, Dominic J; Lee, David P

    2015-01-06

    The TAXUS Liberté Post Approval Study (TL-PAS) contributed patients treated with TAXUS Liberté paclitaxel-eluting stent and prasugrel to the Dual Antiplatelet Therapy Study (DAPT) that compared 12 and 30 months thienopyridine plus aspirin therapy after drug-eluting stents. Outcomes for 2191 TL-PAS patients enrolled into DAPT were assessed. The DAPT coprimary composite end point (death, myocardial infarction [MI], or stroke) was lower with 30 compared with 12 months prasugrel treatment (3.7% versus 8.8%; hazard ratio [HR], 0.407; P<0.001). Rates of death and stroke were similar between groups, but MI was significantly reduced with prolonged prasugrel treatment (1.9% versus 7.1%; HR, 0.255; P<0.001). The DAPT coprimary end point, stent thrombosis, was also lower with longer therapy (0.2% versus 2.9%; HR, 0.063; P<0.001). MI related to stent thrombosis (0% versus 2.6%; P<0.001) and occurring spontaneously (1.9% versus 4.5%; HR, 0.407; P=0.007) were both reduced with prolonged prasugrel. MI rates increased within 90 days of prasugrel cessation after both 12 and 30 months treatment. Composite Global Utilization of Streptokinase and Tissue Plasminogen Activator for Occluded Coronary Arteries (GUSTO) moderate or severe bleeds were modestly increased (2.4% versus 1.7%; HR, 1.438; P=0.234) but severe bleeds were not more frequent (0.3% versus 0.5%; HR, 0.549; P=0.471) in the prolonged treatment group. Prasugrel and aspirin continued for 30 months reduced ischemic events for the TAXUS Liberté paclitaxel-eluting stent patient subset from DAPT through reductions in MI and stent thrombosis. Withdrawal of prasugrel was followed by an increase in MI after both 12 and 30 months therapy. The optimal duration of dual antiplatelet therapy with prasugrel after TAXUS Liberté paclitaxel-eluting stent remains unknown, but appears to be >30 months. http://www.clinicaltrials.gov. Unique identifier: NCT00997503. © 2014 American Heart Association, Inc.

  5. Evaluation of XIENCE V everolimus-eluting and Taxus Express2 paclitaxel-eluting coronary stents in patients with jailed side branches from the SPIRIT IV trial at 2 years.

    PubMed

    Forrest, John K; Lansky, Alexandra J; Meller, Stephanie M; Hou, Liming; Sood, Poornima; Applegate, Robert J; Wang, John C; Skelding, Kimberly A; Shah, Aakar; Kereiakes, Dean J; Sudhir, Krishnankutty; Cristea, Ecaterina; Yaqub, Manejeh; Stone, Gregg W

    2013-06-01

    The aim of this study was to determine whether patients from the Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Patients With de Novo Native Coronary Artery Lesions (SPIRIT) IV trial who underwent percutaneous coronary intervention, who had target lesions with jailed side branches, had improved clinical outcomes when treated with the XIENCE V versus Taxus Express(2) drug-eluting stent. In the SPIRIT III randomized trial, patients with target lesions with jailed side branches after XIENCE V compared with Taxus Express(2) implantation had lower 2-year rates of major adverse cardiac events. The SPIRIT IV trial represents a larger more diverse patient population compared with SPIRIT III. In the large-scale, prospective, multicenter, randomized SPIRIT IV trial, 3,687 patients who underwent coronary stenting with up to 3 de novo native coronary artery lesions were randomized 2:1 to receive XIENCE V versus Taxus Express(2) stents. Two-year clinical outcomes of patients with or without jailed side branches after stenting were compared. A jailed side branch was defined as any side branch >1.0 mm in diameter within the target segment being stented, excluding bifurcations deemed to require treatment. Of the 3,687 patients in SPIRIT IV, a total of 1,426 had side branches that were jailed during angioplasty of the target lesion. Patients with jailed side branches after XIENCE V compared with Taxus Express(2) implantation had significantly lower 2-year rates of target lesion failure (6.5% vs 11.9%, p = 0.001), major adverse cardiac events (6.6% vs 12.2%, p = 0.0008), ischemia-driven target vessel revascularization (4.1% vs 7.9%, p = 0.004), and stent thrombosis (0.6% vs 2.8%, p = 0.001). In conclusion, patients with jailed side branches after stenting with XIENCE V compared to Taxus Express(2) devices had superior clinical outcomes at 2 years in the large-scale randomized SPIRIT IV trial. Copyright © 2013 Elsevier Inc. All

  6. Bare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis

    PubMed Central

    Toklu, Bora; Amoroso, Nicholas; Fusaro, Mario; Kumar, Sunil; Hannan, Edward L; Faxon, David P; Feit, Frederick

    2013-01-01

    Objective To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. Design Mixed treatment comparison meta-analysis of 258 544 patient years of follow-up from randomized trials. Data sources and study selection PubMed, Embase, and Central were searched for randomized trials comparing any of the Food and Drug Administration approved durable polymer drug eluting stents (sirolimus eluting, paclitaxel eluting, cobalt chromium everolimus eluting, platinum chromium everolimus eluting, zotarolimus eluting-Endeavor, and zotarolimus eluting-Resolute) or biodegradable polymer drug eluting stents, with each other or against bare metal stents. Outcomes Long term efficacy (target vessel revascularization, target lesion revascularization) and safety (death, myocardial infarction, stent thrombosis). Landmark analysis at more than one year was evaluated to assess the potential late benefit of biodegradable polymer drug eluting stents. Results From 126 randomized trials and 258 544 patient years of follow-up, for long term efficacy (target vessel revascularization), biodegradable polymer drug eluting stents were superior to paclitaxel eluting stents (rate ratio 0.66, 95% credibility interval 0.57 to 0.78) and zotarolimus eluting stent-Endeavor (0.69, 0.56 to 0.84) but not to newer generation durable polymer drug eluting stents (for example: 1.03, 0.89 to 1.21 versus cobalt chromium everolimus eluting stents). Similarly, biodegradable polymer drug eluting stents were superior to paclitaxel eluting stents (rate ratio 0.61, 0.37 to 0.89) but inferior to cobalt chromium everolimus eluting stents (2.04, 1.27 to 3.35) for long term safety (definite stent thrombosis). In the landmark analysis after one year, biodegradable polymer drug eluting stents were superior to sirolimus eluting stents for definite stent thrombosis (rate ratio 0.29, 0.10 to 0.82) but were associated with increased

  7. Direct comparison of the short-term clinical performance of Z Guidant and Taxus stents.

    PubMed

    Guildford, Anna; Colombo, Paola; Bruschi, Giuseppe; Bonacina, Edgardo; Klugmann, Silvio; Santin, Matteo

    2010-12-03

    The recent introduction of drug-eluting stents in angioplasty of atherosclerotic blood vessels has significantly reduced the risks of in-stent restenosis (ISR) [1]. Indeed, it is known that in conventional stents ISR takes place in over 20% of the cases and up to 60% when implanted in diabetic patients. Conversely, clinical trials have shown that drug-eluting stents have significantly reduced ISR. Among the drug-eluting stents available on the market, Taxus stents (Tax, Boston Scientific, USA) are among the most used devices [2]. Tax are stainless-steel stents coated with Translute, a poly(styrene-b-isobutylene-b-styrene) polymer (PSIBS) eluting Placlitaxel, an anti-mitotic drug. Clinical trials on this type of drug-eluting stents have shown an incidence of restenosis of approximately 4%. The majority of these trials were randomized studies where conventional stents and drug-eluting devices have been implanted in separate patients' cohorts. Such a randomized design, although fundamental to collect statistically-relevant data, does not allow a direct histological comparison of different stent types when implanted in the same patient and do not show the individual susceptibility to the host response especially at short-term implantation times. Here, an interesting case study is presented where two chrome-cobalt stents (Z Guidant, ZG, Guidant Corp.) and a Tax have been simultaneously implanted in the same patient in three separate coronary arteries, retrieved after only 8 weeks and histologically analysed. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  8. Usage patterns and 1-year outcomes with the TAXUS Liberté stent: results of the TAXUS OLYMPIA registry.

    PubMed

    Ahmed, Waqar H; Mendiz, Oscar A; Thomas, Martyn R

    2011-06-01

    The TAXUS OLYMPIA registry is a prospective, global, post-approval program designed to collect clinical outcome data through 1 year from patients receiving the TAXUS Liberté paclitaxel-eluting stent in routine interventional cardiology practice. The thin-strut TAXUS Liberté stent has been studied in ongoing clinical trials with specific inclusion/exclusion criteria. Between September 2005 and April 2007, a total of 21,954 patients from 365 sites in 57 countries eligible to receive a TAXUS Liberté stent were enrolled in the TAXUS OLYMPIA registry. Baseline characteristics and procedure patterns were collected and clinical follow-up is available for 1 year. The primary endpoint was the composite cardiac event (cardiac death, MI, and reintervention of the target vessel) rate related to the TAXUS Liberté stent at 1 year. All cardiac events were monitored and all endpoints were independently adjudicated. Complex patients and lesions were prevalent, including: 27% medically-treated diabetes, 58% ACC/AHA type B2/C lesions, 32% multiple stenting, 13% long lesions (>28 mm), and 10% small vessels (<2.5 mm). At 1 year, the composite cardiac event rate was 4.4%, including 1.4% cardiac death, 1.0% MI, and 3.2% TVR. Stent thrombosis (ST, angiographically confirmed) occurred in 0.8% of patients, with 0.4% ST occurring >30 days postprocedure. The composite cardiac event rate related to the TAXUS Liberté stent was 3.8% at 1 year. Low 1-year cardiac event rates were reported with TAXUS Liberté in a broad spectrum of patients, thereby confirming the technical and clinical performance of this stent in a "real-world" setting. Copyright © 2010 Wiley-Liss, Inc.

  9. Recent Advances in Drug Eluting Stents

    PubMed Central

    Puranik, Amey S.; Dawson, Eileen R.; Peppas, Nicholas A.

    2013-01-01

    One of the most common medical interventions to reopen an occluded vessel is the implantation of a coronary stent. While this method of treatment is effective initially, restenosis, or the re-narrowing of the artery frequently occurs largely due to neointimal hyperplasia of smooth muscle cells. Drug eluting stents were developed in order to provide local, site-specific, controlled release of drugs that can inhibit neointima formation. By implementing a controlled release delivery system it may be possible to control the time release of the pharmacological factors and thus be able to bypass some of the critical events associated with stent hyperplasia and prevent the need for subsequent intervention. However, since the advent of first-generation drug eluting stents, long-term adverse effects have raised concerns regarding their safety. These limitations in safety and efficacy have triggered considerable research in developing biodegradable stents and more potent drug delivery systems. In this review, we shed light on the current state-of-the-art in drug eluting stents, problems related to them and highlight some of the ongoing research in this area. PMID:23117022

  10. An everolimus-eluting stent versus a paclitaxel-eluting stent in small vessel coronary artery disease: a pooled analysis from the SPIRIT II and SPIRIT III trials.

    PubMed

    Bartorelli, Antonio L; Serruys, Patrick W; Miquel-Hébert, Karine; Yu, Shui; Pierson, Wes; Stone, Gregg W

    2010-07-01

    To evaluate the safety and efficacy of the XIENCE V everolimus-eluting stent compared to the TAXUS paclitaxel-eluting stent in small vessels. The XIENCE V everolimus-eluting stent (EES) has been shown to improve angiographic and clinical outcomes after percutaneous myocardial revascularization, but its performance in small coronary arteries has not been investigated. In this pooled analysis, we studied a cohort of 541 patients with small coronary vessels (reference diameter <2.765 mm) by using patient and lesion level data from the SPIRIT II and SPIRIT III studies. TAXUS Express (73% of lesions) and TAXUS Liberté (27% of lesions) paclitaxel-eluting stents (PES) were used as controls in SPIRIT II. In SPIRIT III, Taxus Express(2) PES was the control. Mean angiographic in-stent and in-segment late loss was significantly less in the EES group compared with the PES group, (0.15 +/- 0.37 mm vs. 0.30 +/- 0.44 mm; P = 0.011 for in-stent; 0.10 +/- 0.38 mm vs. 0.21 +/- 0.34 mm; P = 0.034 for in-segment). EES also resulted in a significant reduction in composite major adverse cardiac events at 1 year (19/366 [5.2%] vs. 17/159 [10.7%]; P = 0.037), due to fewer non-Q-wave myocardial infarctions and target lesion revascularizations. At 1 year, the rate of non-Q-wave myocardial infarction was significantly lower in the EES group compared with that of the PES group (6/366 [1.6%] vs. 8/159 [5.0%]; P = 0.037). In patients with small vessel coronary arteries, the XIENCE V EES was superior to the TAXUS PES. (c) 2010 Wiley-Liss, Inc.

  11. One-year outcomes with the Taxus Liberté stent in the real world: the Taxus Olympia registry (phase I).

    PubMed

    Ahmed, Waqar Habib; Zambahari, Robaayah; Al-Rashdan, Ibrahim; Al Naeemi, Abdullah; Saeed, Fuad A; Mascioli, Stephen

    2008-12-01

    The Taxus Olympia registry is a prospective, postapproval registry collecting clinical outcomes data on patients receiving the Taxus Liberté paclitaxel-eluting stent during routine interventional cardiology practice. Between February and July 2005, 529 patients receiving the Taxus Liberté stent at 16 centers in the Middle East, South/Central America, and Asia/Pacific regions were enrolled in Phase I of Olympia. The primary end-point was Taxus Liberté stent-related cardiac events (cardiac death, MI, and revascularization) at 30 days postimplant. Additional clinical assessment was conducted at 6 and 12 months. Olympia phases II and III are in clinical follow-up and will be reported separately. One-year clinical follow-up is available for 98% of patients. Complex patients and lesions were prevalent, including: 50% diabetes mellitus, 49% multivessel disease, 30% multiple stenting, 48% AHA/ACC type B2/C lesions, 19% long lesions (>26 mm), and 40% small vessels (TAXUS Liberté stent-related cardiac event rate was 3.7% at 1 year. Stent thrombosis (ST) occurred in 1.7% of patients, with three cases occurring >30 days postprocedure. One-year cardiac event rates among complex subpopulations (diabetics 5.0%, multiple stents 3.8%, long lesions 3.1%, and small vessels 2.9%) were comparable to the overall study population. In conclusion, this first report of real-world experience with the Taxus Liberté stent demonstrates the safety and clinical utility of this stent in the broader spectrum of coronary disease treated in everyday practice.

  12. Drug-eluting versus bare-metal coronary stents: where are we now?

    PubMed

    Amoroso, Nicholas S; Bangalore, Sripal

    2012-11-01

    Drug-eluting stents have dramatically reduced the risk of restenosis, but concerns of an increased risk of stent thrombosis have provided uncertainty about their use. Recent studies have continued to show improved procedural and clinical outcomes with drug-eluting stents both in the setting of acute coronary syndromes and stable coronary artery disease. Newer generation drug-eluting stents (especially everolimus-eluting stents) have been shown to be not only efficacious but also safe with reduced risk of stent thrombosis when compared with bare-metal stents, potentially changing the benchmark for stent safety from bare-metal stents to everolimus-eluting stents. While much progress is being made in the development of bioabsorbable polymer stents, nonpolymer stents and bioabsorbable stent technology, it remains to be seen whether these stents will have superior safety and efficacy outcomes compared with the already much improved rates of revascularization and stent thrombosis seen with newer generation stents (everolimus-eluting stents and resolute zotarolimus-eluting stents).

  13. Distribution of angiographic measures of restenosis after drug-eluting stent implantation.

    PubMed

    Byrne, R A; Eberle, S; Kastrati, A; Dibra, A; Ndrepepa, G; Iijima, R; Mehilli, J; Schömig, A

    2009-10-01

    A bimodal distribution of measures of restenosis has been demonstrated at 6-8 months after bare metal stent implantation. Drug-eluting stent (DES) treatment has attenuated the impact of certain factors (eg, diabetes) on restenosis but its effect on the distribution of indices of restenosis is not known. To perform a detailed analysis of the metrics of restenosis indices after DES implantation. Design, settings, Prospective observational study of patients undergoing DES implantation (Cypher, sirolimus-eluting stent; or Taxus, paclitaxel-eluting stent) at two German centres, with repeat angiography scheduled at 6-8 months after coronary stenting. In-stent late luminal loss (LLL) and in-segment percentage diameter stenosis (%DS) as determined by quantitative coronary angiography at recatheterisation. Paired cineangiograms were available for 2057 patients. Overall mean (SD) LLL was 0.31 (0.50) mm; mean (SD) %DS was 30.3 (15.7)%. Distribution of both LLL and %DS differed significantly from normal (Kolmogorov-Smirnov test; p<0.001 for each). For both parameters a mixed distribution model better described the data (likelihood ratio test with 3df; p<0.001 for each). This consisted of two normally distributed subpopulations with means (SD) of 0.10 (0.25) mm and 0.69 (0.60) mm for LLL, and means (SD) of 22.2 (8.6)% and 40.1 (16.6)% for %DS. The results were consistent across subgroups of DES type, "on-label" versus "off-label" indication, and presence or absence of diabetes. LLL and %DS at follow-up angiography after DES implantation have a complex mixed distribution that may be accurately represented by a bimodal distribution model. The introduction of DES treatment has not resulted in elimination of a variable propensity to restenosis among subpopulations of patients with stented lesions.

  14. Effectiveness and safety of drug-eluting stents in Ontario.

    PubMed

    Tu, Jack V; Bowen, James; Chiu, Maria; Ko, Dennis T; Austin, Peter C; He, Yaohua; Hopkins, Robert; Tarride, Jean-Eric; Blackhouse, Gord; Lazzam, Charles; Cohen, Eric A; Goeree, Ron

    2007-10-04

    The placement of drug-eluting stents decreases the frequency of repeat revascularization procedures in patients undergoing percutaneous coronary intervention (PCI) in randomized clinical trials. However, there is uncertainty about the effectiveness of drug-eluting stents, and increasing concern about their safety, in routine clinical practice. From the Cardiac Care Network of Ontario's population-based clinical registry of all patients undergoing PCI in Ontario, Canada, we identified a well-balanced cohort of 3751 pairs of patients, matched on the basis of propensity score, who received either bare-metal stents alone or drug-eluting stents alone during an index PCI procedure between December 1, 2003, and March 31, 2005. The primary outcomes of the study were the rates of target-vessel revascularization, myocardial infarction, and death. The 2-year rate of target-vessel revascularization was significantly lower among patients who received drug-eluting stents than among those who received bare-metal stents (7.4% vs. 10.7%, P<0.001). Drug-eluting stents were associated with significant reductions in the rate of target-vessel revascularization among patients with two or three risk factors for restenosis (i.e., presence of diabetes, small vessels [<3 mm in diameter], and long lesions [> or =20 mm]) but not among lower-risk patients. The 3-year mortality rate was significantly higher in the bare-metal-stent group than in the drug-eluting-stent group (7.8% vs. 5.5%, P<0.001), whereas the 2-year rate of myocardial infarction was similar in the two groups (5.2% and 5.7%, respectively; P=0.95). Drug-eluting stents are effective in reducing the need for target-vessel revascularization in patients at highest risk for restenosis, without a significantly increased rate of death or myocardial infarction. Copyright 2007 Massachusetts Medical Society.

  15. Biodegradable-polymer drug-eluting stents vs. bare metal stents vs. durable-polymer drug-eluting stents: a systematic review and Bayesian approach network meta-analysis.

    PubMed

    Kang, Si-Hyuck; Park, Kyung Woo; Kang, Do-Yoon; Lim, Woo-Hyun; Park, Kyung Taek; Han, Jung-Kyu; Kang, Hyun-Jae; Koo, Bon-Kwon; Oh, Byung-Hee; Park, Young-Bae; Kandzari, David E; Cohen, David J; Hwang, Seung-Sik; Kim, Hyo-Soo

    2014-05-01

    The aim of this study was to compare the safety and efficacy of biodegradable-polymer (BP) drug-eluting stents (DES), bare metal stents (BMS), and durable-polymer DES in patients undergoing coronary revascularization, we performed a systematic review and network meta-analysis using a Bayesian framework. Study stents included BMS, paclitaxel-eluting (PES), sirolimus-eluting (SES), endeavor zotarolimus-eluting (ZES-E), cobalt-chromium everolimus-eluting (CoCr-EES), platinium-chromium everolimus-eluting (PtCr-EES), resolute zotarolimus-eluting (ZES-R), and BP biolimus-eluting stents (BP-BES). After a systematic electronic search, 113 trials with 90 584 patients were selected. The principal endpoint was definite or probable stent thrombosis (ST) defined according to the Academic Research Consortium within 1 year. Biodegradable polymer-biolimus-eluting stents [OR, 0.56; 95% credible interval (CrI), 0.33-0.90], SES (OR, 0.53; 95% CrI, 0.38-0.73), CoCr-EES (OR, 0.34; 95% CrI, 0.23-0.52), and PtCr-EES (OR, 0.31; 95% CrI, 0.10-0.90) were all superior to BMS in terms of definite or probable ST within 1 year. Cobalt-chromium everolimus-eluting stents demonstrated the lowest risk of ST of all stents at all times after stent implantation. Biodegradable polymer-biolimus-eluting stents was associated with a higher risk of definite or probable ST than CoCr-EES (OR, 1.72; 95% CrI, 1.04-2.98). All DES reduced the need for repeat revascularization, and all but PES reduced the risk of myocardial infarction compared with BMS. All DESs but PES and ZES-E were superior to BMS in terms of ST within 1 year. Cobalt-chromium everolimus-eluting stents was safer than any DES even including BP-BES. Our results suggest that not only the biodegradability of polymer, but the optimal combination of stent alloy, design, strut thickness, polymer, and drug all combined determine the safety of DES.

  16. Differentiated analysis of an everolimus-eluting stent and a paclitaxel-eluting stent among higher risk subgroups for restenosis: results from the SPIRIT II trial.

    PubMed

    Khattab, Ahmed A; Richardt, Gert; Verin, Vitali; Kelbaek, Henning; Macaya, Carlos; Berland, Jacques; Miquel-Hebert, Karine; Dorange, Cécile; Serruys, Patrick W

    2008-03-01

    Restenosis is higher among certain subpopulations when subjected to percutaneous coronary interventions even when using drug-eluting stents. The randomised SPIRIT II trial demonstrated the superiority of the XIENCE V Everolimus Eluting Coronary Stent System over the TAXUS Paclitaxel-Eluting Stent System in terms of in-stent late loss at six months among 300 patients treated for de novo native coronary artery lesions. In this post-hoc analysis of SPIRIT II we focused on six-month angiographic outcomes of diabetic patients (n=69), left anterior descending arteries (n=149), long lesions >20 mm (n=43), small vessels <3.0 mm (n=209) and type B2 and C lesions (n=233). In-stent late loss was consistently less among all subgroups when treated by everolimus-eluting stents compared to paclitaxel-eluting stents: diabetics 0.15+/-0.26 mm versus 0.39+/-0.34 mm, p=0.006; LAD 0.12+/-0.23 mm versus 0.44+/-0.37 mm, p<0.001; long lesions 0.13+/-0.26 mm versus 0.43+/-0.46 mm, p=0.070; small vessels 0.17+/-0.28 mm versus 0.37+/-0.39 mm, p<0.001; B2/C lesions 0.12+/-0.31 mm versus 0.36+/-0.36 mm, p<0.001. The everolimus-eluting stent remained superior in terms of in-stent late loss in a variety of higher risk populations for restenosis compared to the paclitaxel-eluting stent. These analyses were consistent with the in-stent late loss results of the overall SPIRIT II trial population.

  17. Percutaneous coronary intervention with second-generation paclitaxel-eluting stents versus everolimus-eluting stents in United States contemporary practice (REWARDS TLX Trial).

    PubMed

    Waksman, Ron; Ghali, Magdi; Goodroe, Randy; Ryan, Thomas; Turco, Mark; Ring, Michael; McGarry, Thomas; Dobies, David; Shammas, Nicolas; Steinberg, Daniel H; Swymelar, Stacy; Kaneshige, Kimberly; Torguson, Rebecca

    2012-10-15

    Registry Experience at the Washington Hospital Center, DES - Taxus Liberte Versus Xience V (REWARDS TLX) is a physician-initiated, retrospective, real-world, multicenter, observational study for all patients >18 years of age subjected to percutaneous coronary intervention with everolimus-eluting stents (EESs) or paclitaxel-eluting stents (PESs). Outcomes of patients receiving a TAXUS Liberté or XIENCE V drug-eluting stent were compared. Baseline clinical, procedural, and follow-up data at 12 months were collected from 10 clinical centers by an electronic data capture system. The study's primary end point was major adverse cardiac events: a composite of all-cause death, Q-wave myocardial infarction, target vessel revascularization, and stent thrombosis. The trial is registered with http://www.clinicaltrials.gov (NCT01134159). Data were entered for 1,195 patients (PES, n = 595; EES, n = 600). Baseline clinical characteristics were similar except for higher dyslipidemia, systemic hypertension, and family history of coronary artery disease in the EES group. In-hospital outcome was similar between groups, with an overall in-hospital stent thrombosis rate of 0.2%. The primary end point at 12 months was similar (EES 7.8% vs 10.8%, p = 0.082). Overall stent thrombosis rate was lower in the EES group (0.3% vs 1.2%, respectively, p = 0.107); however, target lesion revascularization was similar (PES, hazard ratio 1.46, 95% confidence interval 0.98 to 2.19, p = 0.064). There was no difference in overall mortality between groups. In conclusion, second-generation EESs and PESs demonstrated similar efficacy and safety profiles for broadened patient and lesion subsets compared to a selected population from the pivotal trials. However, for composite efficacy and safety end points, EESs outperformed second-generation PESs. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Comparison of in-hospital and long-term outcomes between a Cypher stent and a Taxus stent in Chinese diabetic patients with coronary artery disease.

    PubMed

    Yang, Yue-jin; Xu, Bo; Kang, Sheng; Pei, Wei-dong; Chen, Ji-lin; Qiao, Shu-bin; Qin, Xue-wen; Yao, Min; Chen, Jue; Wu, Yong-jian; Liu, Hai-Bo; You, Shi-Jie; Li, Jian-Jun; Dai, Jun; Gao, Run-Lin

    2007-11-05

    The sirolimus and paclitaxel distribution patterns and tissue residence time may be modified in atherosclerotic lesions for patients with diabetes, and the biological mechanisms of action for these agents differ significantly. Previous clinical trials have yielded discrepant results of major adverse cardiac events and restenosis between a sirolimus-eluting stent and a paclitaxel-eluting stent in coronary artery disease. Therefore, this study was conducted to compare in-hospital and long-term clinical outcomes between patients receiving sirolimus-eluting stent (Cypher or Cypher Select stent) and paclitaxel-eluting stent (Taxus Express stent) after percutaneous intervention (PCI) in Chinese patients with diabetes. One hundred and sixty-four consecutive diabetic patients underwent PCI in Fuwai Hospital from April 2004 to December 2004. Of them, 101 patients received Cypher or Cypher Select stents (Cypher group, 145 stents) and 63 patients received Taxus Express stents (Taxus group, 129 stents). Repeat coronary angiography was performed at 6-month and clinical outcomes were evaluated at 1- and 3-year follow-up. Stent thrombosis was classified according to Academic Research Consortium (ARC). The two groups did not differ significantly with respect to cardiac death, recurrent myocardial infarction (re-MI), target vessel revascularization (TVR) and occurrence of major adverse cardiac events (MACE). And the MACE-free cumulative survival at 1- and 3-year follow-up and early, late and very late thrombosis rates were also similar in the two groups (all P > 0.05). There was a trend favoring PES over SES with regard to reducing cardiac death (0 vs 2.0%, P = 0.524), re-MI (0 vs 2.0%, P = 0.524), the composite of the cardiac death and re-MI (0 vs 4.0%, P = 0.299) and very late thrombosis (0 vs 3.0%, P = 0.295) between 1-year and 3-year follow-up. The study indicates that PCI with either Cypher or Taxus stents is associated with similar efficacy and safety in the small population

  19. Economic modeling of new stent platforms to evaluate cost effectiveness: analysis of the TAXUS Liberté versus TAXUS express stents.

    PubMed

    Turco, Mark A; Kansal, Anuraag R; Stern, Sean; Amorosi, Stacey L; Underwood, Paul L; Lissovoy, Greg D E; Dawkins, Keith D

    2012-08-01

    With the changing health care environment, cost effectiveness is an important adjunct to clinical investigation when assessing new medical devices. This study presents an economic model to evaluate cost effectiveness of coronary stents. Markov modeling was developed comparing total costs (Medicare payer perspective) between TAXUS Liberté and TAXUS Express based on 3-year clinical outcomes from the TAXUS ATLAS Small Vessel and Long Lesion trials. The TAXUS Liberté 2.25-mm stent provided cost savings relative to TAXUS Express from a payer perspective ($17,605 vs. $20,281), driven by reduced target vessel revascularization (0.16 events/patient vs. 0.33 events/patient). In probabilistic sensitivity analyses, TAXUS Liberté was less costly with fewer major adverse cardiac events in over 99% of parameter sets. The TAXUS Liberté Long (38 mm) stent was cost neutral relative to TAXUS Express from a payer perspective ($18,545 vs. $18,551) with fewer myocardial infarctions and cardiac deaths. Accounting for angiography-driven revascularizations, TAXUS Liberté 2.25 mm still provided cost savings relative to TAXUS Express ($16,822 vs. $19,139), although TAXUS Liberté Long was more expensive than TAXUS Express ($17,886 vs. $17,652). From a hospital perspective, TAXUS Liberté Long provided cost savings up to a price premium of $671/stent, driven by fewer stents employed per patient. This analysis confirms the utility of economic modeling in assessing new stent platforms. TAXUS Liberté 2.25 mm is economically dominant relative to TAXUS Express when treating small vessels. TAXUS Liberté Long is cost neutral to modestly more costly than TAXUS Express 2.25 mm from a payer perspective. ©2012, Wiley Periodicals, Inc.

  20. Drug eluting biliary stents to decrease stent failure rates: A review of the literature

    PubMed Central

    Shatzel, Joseph; Kim, Jisoo; Sampath, Kartik; Syed, Sharjeel; Saad, Jennifer; Hussain, Zilla H; Mody, Kabir; Pipas, J Marc; Gordon, Stuart; Gardner, Timothy; Rothstein, Richard I

    2016-01-01

    Biliary stenting is clinically effective in relieving both malignant and non-malignant obstructions. However, there are high failure rates associated with tumor ingrowth and epithelial overgrowth as well as internally from biofilm development and subsequent clogging. Within the last decade, the use of prophylactic drug eluting stents as a means to reduce stent failure has been investigated. In this review we provide an overview of the current research on drug eluting biliary stents. While there is limited human trial data regarding the clinical benefit of drug eluting biliary stents in preventing stent obstruction, recent research suggests promise regarding their safety and potential efficacy. PMID:26839648

  1. Modelling Simple Experimental Platform for In Vitro Study of Drug Elution from Drug Eluting Stents (DES)

    NASA Astrophysics Data System (ADS)

    Kalachev, L. V.

    2016-06-01

    We present a simple model of experimental setup for in vitro study of drug release from drug eluting stents and drug propagation in artificial tissue samples representing blood vessels. The model is further reduced using the assumption on vastly different characteristic diffusion times in the stent coating and in the artificial tissue. The model is used to derive a relationship between the times at which the measurements have to be taken for two experimental platforms, with corresponding artificial tissue samples made of different materials with different drug diffusion coefficients, to properly compare the drug release characteristics of drug eluting stents.

  2. Update on the everolimus-eluting coronary stent system: results and implications from the SPIRIT clinical trial program

    PubMed Central

    Kirchner, R Michael; Abbott, J Dawn

    2009-01-01

    Drug-eluting stents (DES) have had a major impact in interventional cardiology. Compared to bare metal stents, they significantly reduce restenosis and the need for target vessel revascularization. Four DES are available in the US, the first-generation sirolimus-eluting (Cypher®) and paclitaxel-eluting (Taxus®) stents and later approved second-generation everolimus-eluting (Xience V®) and zotarolimus-eluting (Endeavor®) stents. The Xience V stent was approved on the basis of clinical efficacy and safety data from 3 studies in the SPIRIT clinical trial program. Within this trial series, the Xience V was superior to its bare metal stent counterpart, the Vision® stent, and noninferior to the paclitaxel-eluting stent for target vessel failure at 9 months. This review provides a comprehensive assessment of the data derived from both the pre- and post-approval randomized controlled trials and registry studies of Xience V that comprise the SPIRIT clinical trial program including recently published mid-term outcomes. The implications of the results in terms of interventional practice will be discussed. PMID:20057901

  3. Paclitaxel Drug-Eluting Stents in Peripheral Arterial Disease: A Health Technology Assessment

    PubMed Central

    2015-01-01

    Background Peripheral arterial disease is a condition in which atherosclerotic plaques partially or completely block blood flow to the legs. Although percutaneous transluminal angioplasty and metallic stenting have high immediate success rates in treating peripheral arterial disease, long-term patency and restenosis rates in long and complex lesions remain unsatisfactory. Objective The objective of this analysis was to evaluate the clinical effectiveness, safety, cost-effectiveness and budget impact of Zilver paclitaxel self-expanding drug-eluting stents for the treatment of de novo or restenotic lesions in above-the-knee peripheral arterial disease. Data Sources Literature searches were performed using Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid Embase, EBSCO Cumulative Index to Nursing & Allied Health Literature (CINAHL), and EBM Reviews. For the economic review, a search filter was applied to limit search results to economics-related literature. Data sources for the budget impact analysis included expert opinion, published literature, and Ontario administrative data. Review Methods Systematic reviews, meta-analyses, randomized controlled trials, and observational studies were included in the clinical effectiveness review, and full economic evaluations were included in the economic literature review. Studies were included if they examined the effect of Zilver paclitaxel drug-eluting stents in de novo or restenotic lesions in above-the-knee arteries. For the budget impact analysis, 3 scenarios were constructed based on different assumptions. Results One randomized controlled trial reported a significantly higher patency rate with Zilver paclitaxel drug-eluting stents for lesions ≤ 14 cm than with angioplasty or bare metal stents. One observational study showed no difference in patency rates between Zilver paclitaxel drug-eluting stents and paclitaxel drug-coated balloons. Zilver paclitaxel drug-eluting stents were associated with

  4. Drug-eluting stents to prevent stent thrombosis and restenosis.

    PubMed

    Im, Eui; Hong, Myeong-Ki

    2016-01-01

    Although first-generation drug-eluting stents (DES) have significantly reduced the risk of in-stent restenosis, they have also increased the long-term risk of stent thrombosis. This safety concern directly triggered the development of new generation DES, with innovations in stent platforms, polymers, and anti-proliferative drugs. Stent platform materials have evolved from stainless steel to cobalt or platinum-chromium alloys with an improved strut design. Drug-carrying polymers have become biocompatible or biodegradable and even polymer-free DES were introduced. New limus-family drugs (such as everolimus, zotarolimus or biolimus) were adopted to enhance stent performances. As a result, these new DES demonstrated superior vascular healing responses on intracoronary imaging studies and lower stent thrombotic events in actual patients. Recently, fully-bioresorbable stents (scaffolds) have been introduced, and expanding their applications. In this article, the important concepts and clinical results of new generation DES and bioresorbable scaffolds are described.

  5. Controversies in the use & implementation of drug-eluting stent technology

    PubMed Central

    Itagaki, Brandon K.; Brar, Somjot S.

    2012-01-01

    The introduction of drug eluting stents has resulted in dramatic reductions in the rates of restenosis and the need for repeat revascularization. In the last several years, concern has been raised regarding the long-term safety of this technology, particularly in the area of late restenosis and stent thrombosis. The development of newer anti-restenotic drug coatings, biodegradable polymers and even completely bioabsorbable stents offer the potential to address these limitations. Additional questions that have recently come to the forefront include the optimal duration of dual antiplatelet therapy, the use of platelet reactivity assays and genetic testing and drug eluting stent use in the treatment of acute myocardial infarction. This article will attempt to address these and other areas of controversy in the use and implementation of drug eluting stents. PMID:23391788

  6. Drug eluting stents and modern stent technologies for in-stent restenosis.

    PubMed

    Werner, Martin

    2017-08-01

    The implantation of metallic stents has become a standard procedure to improve the outcome after angioplasty of peripheral vessels. However, the occurrence of in-stent restenosis is hampering the long-term efficacy of these procedures and is associated with re-occurrence of symptoms. The optimal treatment modality for in-stent-restenosis in the peripheral vasculature is not well examined. This review discusses the existing evidence for the treatment of in-stent restenosis with drug eluting stents and modern stent technologies.

  7. Clinical outcomes and stent thrombosis following off-label use of drug-eluting stents.

    PubMed

    Win, Htut K; Caldera, Angel E; Maresh, Kelly; Lopez, John; Rihal, Charanjit S; Parikh, Manish A; Granada, Juan F; Marulkar, Sachin; Nassif, Deborah; Cohen, David J; Kleiman, Neal S

    2007-05-09

    Clinical trials that have excluded patients at high risk for cardiac events have led to commercial labeling approval of drug-eluting stents; nevertheless, such high-risk patients commonly undergo stent placement in clinical practice. The degree to which they experience cardiac events at a higher rate than non-high-risk patients is unclear. To assess the rates of major adverse cardiac events during the index admission and 1 year after the implantation of drug-eluting stents in patients with high-risk angiographic and clinical features. From July 2004 to September 2005, consecutive patients who underwent attempted stent placement at 42 different hospitals throughout the United States were enrolled in a prospective multicenter registry. We analyzed outcomes of 3323 patients who received at least 1 drug-eluting stent for a reason other than acute ST-segment elevation myocardial infarction. The study population was divided into 2 groups based on presence of at least 1 of 9 off-label characteristics based on the current US Food and Drug Administration-approved indications for sirolimus- and paclitaxel-eluting stents. The composite clinical outcomes of death, myocardial infarction, or target vessel revascularization during the index admission and death, myocardial infarction, or target lesion revascularization at 1 year were evaluated. Of the 3323 patients, 1817 (54.7%) had at least 1 off-label characteristic. During the index hospitalization, the composite clinical outcome occurred in 198 (10.9%) of patients in the off-label group and 76 (5.0%) of patients in the on-label group (adjusted odds ratio, 2.32; 95% confidence interval [CI], 1.75-3.07; P<.001). At 1 year, the composite clinical outcome occurred more often in the off-label group compared with the on-label group; 309 (17.5%) vs 131 (8.9%) (adjusted hazard ratio [HR], 2.16; 95% CI, 1.74-2.67; P<.001). Stent thrombosis also occurred more frequently among patients in the off-label group during the initial

  8. Stent thrombosis with drug-eluting and bare-metal stents: evidence from a comprehensive network meta-analysis.

    PubMed

    Palmerini, Tullio; Biondi-Zoccai, Giuseppe; Della Riva, Diego; Stettler, Christoph; Sangiorgi, Diego; D'Ascenzo, Fabrizio; Kimura, Takeshi; Briguori, Carlo; Sabatè, Manel; Kim, Hyo-Soo; De Waha, Antoinette; Kedhi, Elvin; Smits, Pieter C; Kaiser, Christoph; Sardella, Gennaro; Marullo, Antonino; Kirtane, Ajay J; Leon, Martin B; Stone, Gregg W

    2012-04-14

    The relative safety of drug-eluting stents and bare-metal stents, especially with respect to stent thrombosis, continues to be debated. In view of the overall low frequency of stent thrombosis, large sample sizes are needed to accurately estimate treatment differences between stents. We compared the risk of thrombosis between bare-metal and drug-eluting stents. For this network meta-analysis, randomised controlled trials comparing different drug-eluting stents or drug-eluting with bare-metal stents currently approved in the USA were identified through Medline, Embase, Cochrane databases, and proceedings of international meetings. Information about study design, inclusion and exclusion criteria, sample characteristics, and clinical outcomes was extracted. 49 trials including 50,844 patients randomly assigned to treatment groups were analysed. 1-year definite stent thrombosis was significantly lower with cobalt-chromium everolimus eluting stents (CoCr-EES) than with bare-metal stents (odds ratio [OR] 0·23, 95% CI 0·13-0·41). The significant difference in stent thrombosis between CoCr-EES and bare-metal stents was evident as early as 30 days (OR 0·21, 95% CI 0·11-0·42) and was also significant between 31 days and 1 year (OR 0·27, 95% CI 0·08-0·74). CoCr-EES were also associated with significantly lower rates of 1-year definite stent thrombosis compared with paclitaxel-eluting stents (OR 0·28, 95% CI 0·16-0·48), permanent polymer-based sirolimus-eluting stents (OR 0·41, 95% CI 0·24-0·70), phosphorylcholine-based zotarolimus-eluting stents (OR 0·21, 95% CI 0·10-0·44), and Resolute zotarolimus-eluting stents (OR 0·14, 95% CI 0·03-0·47). At 2-year follow-up, CoCr-EES were still associated with significantly lower rates of definite stent thrombosis than were bare-metal (OR 0·35, 95% CI 0·17-0·69) and paclitaxel-eluting stents (OR 0·34, 95% CI 0·19-0·62). No other drug-eluting stent had lower definite thrombosis rates compared with bare

  9. Restenosis of the CYPHER-Select, TAXUS-Express, and Polyzene-F Nanocoated Cobalt-Chromium Stents in the Minipig Coronary Artery Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Radeleff, Boris, E-mail: Boris.radeleff@med.uni-heidelberg.de; Thierjung, Heidi; Stampfl, Ulrike

    2008-09-15

    PurposeTo date no direct experimental comparison between the CYPHER-Select and TAXUS-Express stents is available. Therefore, we investigated late in-stent stenosis, thrombogenicity, and inflammation, comparing the CYPHER-Select, TAXUS-Express, and custom-made cobalt chromium Polyzene-F nanocoated stents (CCPS) in the minipig coronary artery model.MethodsThe three stent types were implanted in the right coronary artery of 30 minipigs. The primary endpoint was in-stent stenosis assessed by quantitative angiography and microscopy. Secondary endpoints were inflammation and thrombogenicity evaluated by scores for inflammation and immunoreactivity (C-reactive protein and transforming growth factor beta). Follow-up was at 4 and 12 weeks.ResultsStent placement was successful in all animals; nomore » thrombus deposition occurred. Quantitative angiography did not depict statistically significant differences between the three stent types after 4 and 12 weeks. Quantitative microscopy at 4 weeks showed a statistically significant thicker neointima (p = 0.0431) for the CYPHER (105.034 {+-} 62.52 {mu}m) versus the TAXUS (74.864 {+-} 66.03 {mu}m) and versus the CCPS (63.542 {+-} 39.57 {mu}m). At 12 weeks there were no statistically significant differences. Inflammation scores at 4 weeks were significantly lower for the CCPS and CYPHER compared with the TAXUS stent (p = 0.0431). After 12 weeks statistical significance was only found for the CYPHER versus the TAXUS stent (p = 0.0431). The semiquantitative immunoreactivity scores for C-reactive protein and transforming growth factor beta showed no statistically significant differences between the three stent types after 4 and 12 weeks.ConclusionsThe CCPS provided effective control of late in-stent stenosis and thrombogenicity in this porcine model compared with the two drug-eluting stents. Its low inflammation score underscores its noninflammatory potential and might explain its equivalence to the two DES.« less

  10. Drug-eluting coronary stents – focus on improved patient outcomes

    PubMed Central

    Jaffery, Zehra; Prasad, Amit; Lee, John H; White, Christopher J

    2011-01-01

    The development of stent has been a major advance in the treatment of obstructive coronary artery disease since the introduction of balloon angioplasty. Subsequently, neointimal hyperplasia within the stent leading to in-stent restenosis emerged as a major obstacle in long-term success of percutaneous coronary intervention. Recent introduction of drug-eluting stents is a major breakthrough to tackle this problem. This review article summarizes stent technology, reviews progress of drug-eluting stents and discusses quality of life, patient satisfaction, and acceptability of percutaneous coronary intervention. PMID:22915977

  11. Drug-eluting stents and acute myocardial infarction: A lethal combination or friends?

    PubMed Central

    Otsuki, Shuji; Sabaté, Manel

    2014-01-01

    Primary percutaneous coronary intervention is the preferred reperfusion strategy for patients presenting with ST-segment elevation myocardial infarction (STEMI). First generation drug-eluting stents (DES), (sirolimus drug-eluting stents and paclitaxel drug-eluting stents), reduce the risk of restenosis and target vessel revascularization compared to bare metal stents. However, stent thrombosis emerged as a major safety concern with first generation DES. In response to these safety issues, second generation DES were developed with different drugs, improved stent platforms and more biocompatible durable or bioabsorbable polymeric coating. This article presents an overview of safety and efficacy of the first and second generation DES in STEMI. PMID:25276295

  12. 3-Year Clinical Follow-Up of the RIBS IV Clinical Trial: A Prospective Randomized Study of Drug-Eluting Balloons Versus Everolimus-Eluting Stents in Patients With In-Stent Restenosis in Coronary Arteries Previously Treated With Drug-Eluting Stents.

    PubMed

    Alfonso, Fernando; Pérez-Vizcayno, María José; Cuesta, Javier; García Del Blanco, Bruno; García-Touchard, Arturo; López-Mínguez, José Ramón; Masotti, Mónica; Zueco, Javier; Cequier, Angel; Velázquez, Maite; Moreno, Raúl; Mainar, Vicente; Domínguez, Antonio; Moris, Cesar; Molina, Eduardo; Rivero, Fernando; Jiménez-Quevedo, Pilar; Gonzalo, Nieves; Fernández-Pérez, Cristina

    2018-05-28

    This study sought to compare the long-term safety and efficacy of drug-eluting balloons (DEB) and everolimus-eluting stents (EES) in patients with in-stent restenosis (ISR) of drug-eluting stents (DES). Treatment of patients with DES-ISR remains a challenge. The RIBS IV (Restenosis Intra-Stent of Drug-Eluting Stents: Drug-Eluting Balloons vs Everolimus-Eluting Stents) trial is a prospective multicenter randomized clinical trial comparing DEB and EES in patients with DES-ISR. The pre-specified comparison of the 3-year clinical outcomes obtained with these interventions is the main objective of the present study. A total of 309 patients with DES-ISR were randomized to DEB (n = 154) or EES (n = 155). At angiographic follow-up, the in-segment minimal lumen diameter was larger in the EES arm (2.03 ± 0.7 mm vs. 1.80 ± 0.6 mm; p < 0.01). Three-year clinical follow-up was obtained in all enrolled patients (100%). The combined clinical outcome measure of cardiac death, myocardial infarction and target lesion revascularization was significantly reduced in the EES arm (19 [12.3%] vs. 31 [20.1%]; p = 0.04; hazard ratio: 0.57 [95% confidence interval: 0.34 to 0.96]), driven by a lower need for target lesion revascularization (11 [7.1%] vs. 24 [15.6%]; p = 0.015; hazard ratio: 0.43 [95% confidence interval: 0.21 to 0.87]). The need for "late" (>1 year) target lesion revascularization (2.6% vs. 4%) and target vessel revascularization (4% vs. 6.6%) was similar in the 2 arms. Rates of cardiac death (3.9% vs. 3.2%), myocardial infarction (2.6% vs. 4.5%), and stent thrombosis (1.3% vs. 2.6%) at 3 years were also similar in both arms. The 3-year clinical follow-up of this randomized clinical trial demonstrates that in patients with DES-ISR, EES reduce the need for repeat interventions compared with DEB. (Restenosis Intra-Stent of Drug-Eluting Stents: Drug-Eluting Balloons vs Everolimus-Eluting Stents [RIBS IV]; NCT01239940). Published by Elsevier Inc.

  13. Biocompatibility of new drug-eluting biodegradable urethral stent materials.

    PubMed

    Kotsar, Andres; Nieminen, Riina; Isotalo, Taina; Mikkonen, Joonas; Uurto, Ilkka; Kellomäki, Minna; Talja, Martti; Moilanen, Eeva; Tammela, Teuvo L J

    2010-01-01

    To investigate the effects of biodegradable stent material (poly-96L/4D-lactic acid [PLA]) on the production of cytokines and other inflammatory mediators in vitro and the biocompatibility of new drug-eluting biodegradable urethral stent materials in vivo. Indomethacin, dexamethasone, and simvastatin were used in the materials. The effects of the biodegradable stent material on cytokines and other inflammatory mediators were measured using the Human Cytokine Antibody Array and enzyme-linked immunosorbent assay in THP-1 cells, with bacterial lipopolysaccharide as a positive control. To assess the biocompatibility of the stent materials, we used muscle implantation. Biodegradable stent materials without drug-eluting properties and silicone and latex were used as controls. The measurements were done at 3 weeks and 3 months. The PLA stent material induced production of inflammatory mediators, especially interleukin-8, tumor necrosis factor-alpha, and transforming growth factor-beta, in vitro. The increase in the production of these mediators with the PLA stent material was smaller than in the cells treated with lipopolysaccharide. In vivo, the effects of the biodegradable materials did not differ at 3 weeks, although, at 3 months, dexamethasone had induced more tissue reactions than had the other materials. At 3 months, fibrosis and chronic inflammatory changes were decreased in the biodegradable material groups compared with the positive control. PLA stent material increased the production of cytokines and other inflammatory mediators less than did positive controls in vitro. The in vivo biocompatibility of the drug-eluting biodegradable materials was better than that of the positive controls. Drug-eluting biodegradable urethral stents could potentially offer a new treatment modality in the future. 2010 Elsevier Inc. All rights reserved.

  14. Everolimus-eluting stents in interventional cardiology

    PubMed Central

    Townsend, Jacob C; Rideout, Phillip; Steinberg, Daniel H

    2012-01-01

    Bare metal stents have a proven safety record, but limited long-term efficacy due to in-stent restenosis. First-generation drug-eluting stents successfully countered the restenosis rate, but were hampered by concerns about their long-term safety. Second generation drug-eluting stents have combined the low restenosis rate of the first generation with improved long-term safety. We review the evolution of drug-eluting stents with a focus on the safety, efficacy, and unique characteristics of everolimus-eluting stents. PMID:22910420

  15. Endovascular Gene Delivery from a Stent Platform: Gene- Eluting Stents

    PubMed Central

    Fishbein, Ilia; Chorny, Michael; Adamo, Richard F; Forbes, Scott P; Corrales, Ricardo A; Alferiev, Ivan S; Levy, Robert J

    2015-01-01

    A synergistic impact of research in the fields of post-angioplasty restenosis, drug-eluting stents and vascular gene therapy over the past 15 years has shaped the concept of gene-eluting stents. Gene-eluting stents hold promise of overcoming some biological and technical problems inherent to drug-eluting stent technology. As the field of gene-eluting stents matures it becomes evident that all three main design modules of a gene-eluting stent: a therapeutic transgene, a vector and a delivery system are equally important for accomplishing sustained inhibition of neointimal formation in arteries treated with gene delivery stents. This review summarizes prior work on stent-based gene delivery and discusses the main optimization strategies required to move the field of gene-eluting stents to clinical translation. PMID:26225356

  16. A new polymer-free drug-eluting stent with nanocarriers eluting sirolimus from stent-plus-balloon compared with bare-metal stent and with biolimus A9 eluting stent in porcine coronary arteries.

    PubMed

    Takimura, Celso K; Galon, Micheli Z; Gutierrez, Paulo S; Sojitra, Prakash; Vyas, Ashwin; Doshi, Manish; Lemos, Pedro A

    2015-04-01

    Permanent polymers in first generation drug-eluting stent (DES) have been imputed to be a possible cause of persistent inflammation, remodeling, malapposition and late stent thrombosis. We aim to describe the in vivo experimental result of a new polymer-free DES eluting sirolimus from stent-plus-balloon (Focus np stent, Envision Scientific) compared with a bare-metal stent (BMS) (Amazonia CroCo, Minvasys) and with a biolimus A9 eluting stent (Biomatrix, Biosensors). In 10 juvenile pigs, 23 coronary stents were implanted in the coronary arteries (8 Amazonia CroCo, 8 Focus np, and 7 Biomatrix). At 28-day follow-up, optical coherence tomography (OCT) and histology were used to evaluate neointimal hyperplasia and healing response. According to OCT analysis, Focus np stents had a greater lumen area and less neointimal hyperplasia response than BMS and Biomatrix had. Histomorphometry results showed less neointimal hyperplasia in Focus np than in BMS. Histology showed a higher fibrin deposition in Biomatrix stent compared to Focus np and BMS. The new polymer-free DES with sirolimus eluted from stent-plus-balloon demonstrated safety and reduced neointimal proliferation compared with the BMS and Biomatrix stents at 28-day follow-up in this porcine coronary model. This new polymer-free DES is promising and warrants further clinical studies.

  17. Current State of Bioabsorbable Polymer-Coated Drug-Eluting Stents

    PubMed Central

    Akinapelli, Abhilash; Chen, Jack P.; Roy, Kristine; Donnelly, Joseph; Dawkins, Keith; Huibregtse, Barbara; Hou, Dongming

    2017-01-01

    Drug-eluting stents (DES) have been shown to significantly reduce clinical and angiograph-ic restenosis compared to bare metal stents (BMS). The polymer coatings on DES elute antiproliferative drugs to inhibit intimal proliferation and prevent restenosis after stent implantation. Permanent poly-mers which do not degrade in vivo may increase the likelihood of stent-related delayed arterial healing or polymer hypersensitivity. In turn, these limitations may contribute to an increased risk of late clinical events. Intuitively, a polymer which degrades after completion of drug release, leaving an inert metal scaffold in place, may improve arterial healing by removing a chronic source of inflammation, neoath-erosclerosis, and/or late thrombosis. In this way, a biodegradable polymer may reduce late ischemic events. Additionally, improved healing after stent implantation could reduce the requirement for long-term dual antiplatelet therapy and the associated risk of bleeding and cost. This review will focus on bioabsorbable polymer-coated DES currently being evaluated in clinical trials.

  18. Drug- and Gene-eluting Stents for Preventing Coronary Restenosis

    PubMed Central

    Lekshmi, Kamali Manickavasagam; Che, Hui-Lian; Cho, Chong-Su

    2017-01-01

    Coronary artery disease (CAD) has been reported to be a major cause of death worldwide. Current treatment methods include atherectomy, coronary angioplasty (as a percutaneous coronary intervention), and coronary artery bypass. Among them, the insertion of stents into the coronary artery is one of the commonly used methods for CAD, although the formation of in-stent restenosis (ISR) is a major drawback, demanding improvement in stent technology. Stents can be improved using the delivery of DNA, siRNA, and miRNA rather than anti-inflammatory/anti-thrombotic drugs. In particular, genes that could interfere with the development of plaque around infected regions are conjugated on the stent surface to inhibit neointimal formation. Despite their potential benefits, it is necessary to explore the various properties of gene-eluting stents. Furthermore, multifunctional electronic stents that can be used as a biosensor and deliver drug- or gene-based on physiological condition will be a very promising way to the successful treatment of ISR. In this review, we have discussed the molecular mechanism of restenosis, the use of drug- and gene-eluting stents, and the possible roles that these stents have in the prevention and treatment of coronary restenosis. Further, we have explained how multifunctional electronic stents could be used as a biosensor and deliver drugs based on physiological conditions. PMID:28184335

  19. A new polymer-free drug-eluting stent with nanocarriers eluting sirolimus from stent-plus-balloon compared with bare-metal stent and with biolimus A9 eluting stent in porcine coronary arteries

    PubMed Central

    Galon, Micheli Z.; Gutierrez, Paulo S.; Sojitra, Prakash; Vyas, Ashwin; Doshi, Manish; Lemos, Pedro A.

    2015-01-01

    Background Permanent polymers in first generation drug-eluting stent (DES) have been imputed to be a possible cause of persistent inflammation, remodeling, malapposition and late stent thrombosis. We aim to describe the in vivo experimental result of a new polymer-free DES eluting sirolimus from stent-plus-balloon (Focus np stent, Envision Scientific) compared with a bare-metal stent (BMS) (Amazonia CroCo, Minvasys) and with a biolimus A9 eluting stent (Biomatrix, Biosensors). Methods In 10 juvenile pigs, 23 coronary stents were implanted in the coronary arteries (8 Amazonia CroCo, 8 Focus np, and 7 Biomatrix). At 28-day follow-up, optical coherence tomography (OCT) and histology were used to evaluate neointimal hyperplasia and healing response. Results According to OCT analysis, Focus np stents had a greater lumen area and less neointimal hyperplasia response than BMS and Biomatrix had. Histomorphometry results showed less neointimal hyperplasia in Focus np than in BMS. Histology showed a higher fibrin deposition in Biomatrix stent compared to Focus np and BMS. Conclusions The new polymer-free DES with sirolimus eluted from stent-plus-balloon demonstrated safety and reduced neointimal proliferation compared with the BMS and Biomatrix stents at 28-day follow-up in this porcine coronary model. This new polymer-free DES is promising and warrants further clinical studies. PMID:25984451

  20. Genous™ endothelial progenitor cell capturing stent vs. the Taxus Liberté stent in patients with de novo coronary lesions with a high-risk of coronary restenosis: a randomized, single-centre, pilot study

    PubMed Central

    Beijk, Marcel A.M.; Klomp, Margo; Verouden, Niels J.W.; van Geloven, Nan; Koch, Karel T.; Henriques, José P.S.; Baan, Jan; Vis, Marije M.; Scheunhage, Esther; Piek, Jan J.; Tijssen, Jan G.P.; de Winter, Robbert J.

    2010-01-01

    Aims The purpose of this study was to evaluate the GenousTM endothelial progenitor cell capturing stent vs. the Taxus Liberté paclitaxel-eluting stent in patients with de novo coronary lesions with a high-risk of coronary restenosis. Methods and results We randomly assigned 193 patients with lesions carrying a high risk of restenosis to have the Genous stent or the Taxus stent implanted. Lesions were considered high risk of restenosis if one of the following applied: chronic total occlusion, lesion length >23 mm, vessel diameter <2.8 mm, or any lesion in a diabetic patient. At 1-year, the rate of the primary end point, target vessel failure (TVF), was 17.3% in the Genous stent group when compared with 10.5% in the Taxus stent group [risk difference (RD) 6.8%, 95% CI −3.1 to 16.7%], a difference predominantly due to a higher incidence of repeat revascularization in patients treated with the Genous stent. In contrast, no stent thrombosis was observed in the Genous stent group compared to 4 stent thromboses in the Taxus stent group (RD −4.2%; 95% CI −10.3 to 0.3%). Repeat angiography between 6 and 12 months in a subgroup of patients showed a significantly higher late loss in the Genous stent compared with the Taxus stent (1.14 ± 0.64 and 0.55 ± 0.61 mm). Conclusion In patients with lesions carrying a high risk of restenosis, the Genous stent resulted in a non-significant higher rate of TVF compared with the Taxus stent mainly due to more repeat revascularizations in the Genous stent group. There were four stent thromboses with Taxus stent, none with the Genous stent. PMID:19933225

  1. Cost-Effectiveness Analysis of Infrapopliteal Drug-Eluting Stents

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr; Karnabatidis, Dimitris; Diamantopoulos, Athanasios

    2013-02-15

    IntroductionThere are no cost-utility data about below-the-knee placement of drug-eluting stents. The authors determined the cost-effectiveness of infrapopliteal drug-eluting stents for critical limb ischemia (CLI) treatment. The event-free individual survival outcomes defined by the absence of any major events, including death, major amputation, and target limb repeat procedures, were reconstructed on the basis of two published infrapopliteal series. The first included spot Bail-out use of Sirolimus-eluting stents versus bare metal stents after suboptimal balloon angioplasty (Bail-out SES).The second was full-lesion Primary Everolimus-eluting stenting versus plain balloon angioplasty and bail-out bare metal stenting as necessary (primary EES). The number-needed-to-treat (NNT) tomore » avoid one major event and incremental cost-effectiveness ratios (ICERs) were calculated for a 3-year postprocedural period for both strategies. Overall event-free survival was significantly improved in both strategies (hazard ratio (HR) [confidence interval (CI)]: 0.68 [0.41-1.12] in Bail-out SES and HR [CI]: 0.53 [0.29-0.99] in Primary EES). Event-free survival gain per patient was 0.89 (range, 0.11-3.0) years in Bail-out SES with an NNT of 4.6 (CI: 2.5-25.6) and a corresponding ICER of 6,518 Euro-Sign (range 1,685-10,112 Euro-Sign ). Survival gain was 0.91 (range 0.25-3.0) years in Primary EES with an NNT of 2.7 (CI: 1.7-5.8) and an ICER of 11,581 Euro-Sign (range, 4,945-21,428 Euro-Sign ) per event-free life-year gained. Two-way sensitivity analysis showed that stented lesion length >10 cm and/or DES list price >1000 Euro-Sign were associated with the least economically favorable scenario in both strategies. Both strategies of bail-out SES and primary EES placement in the infrapopliteal arteries for CLI treatment exhibit single-digit NNT and relatively low corresponding ICERs.« less

  2. Paclitaxel Drug-eluting Tracheal Stent Could Reduce Granulation Tissue Formation in a Canine Model

    PubMed Central

    Wang, Ting; Zhang, Jie; Wang, Juan; Pei, Ying-Hua; Qiu, Xiao-Jian; Wang, Yu-Ling

    2016-01-01

    Background: Currently available silicone and metallic stents for tracheal stenosis are associated with many problems. Granulation proliferation is one of the main complications. The present study aimed to evaluate the efficacy of paclitaxel drug-eluting tracheal stent in reducing granulation tissue formation in a canine model, as well as the pharmacokinetic features and safety profiles of the coated drug. Methods: Eight beagles were randomly divided into a control group (bare-metal stent group, n = 4) and an experimental group (paclitaxel-eluting stent group, n = 4). The observation period was 5 months. One beagle in both groups was sacrificed at the end of the 1st and 3rd months, respectively. The last two beagles in both groups were sacrificed at the end of 5th month. The proliferation of granulation tissue and changes in tracheal mucosa were compared between the two groups. Blood routine and liver and kidney function were monitored to evaluate the safety of the paclitaxel-eluting stent. The elution method and high-performance liquid chromatography were used to characterize the rate of in vivo release of paclitaxel from the stent. Results: Compared with the control group, the proliferation of granulation tissue in the experimental group was significantly reduced. The drug release of paclitaxel-eluting stent was the fastest in the 1st month after implantation (up to 70.9%). Then, the release slowed down gradually. By the 5th month, the release reached up to 98.5%. During the observation period, a high concentration of the drug in the trachea (in the stented and adjacent unstented areas) and lung tissue was not noted, and the blood test showed no side effect. Conclusions: The paclitaxel-eluting stent could safely reduce the granulation tissue formation after stent implantation in vivo, suggesting that the paclitaxel-eluting tracheal stent might be considered for potential use in humans in the future. PMID:27824004

  3. Stent Thrombosis With Drug-Eluting Stents and Bioresorbable Scaffolds: Evidence From a Network Meta-Analysis of 147 Trials.

    PubMed

    Kang, Si-Hyuck; Chae, In-Ho; Park, Jin-Joo; Lee, Hak Seung; Kang, Do-Yoon; Hwang, Seung-Sik; Youn, Tae-Jin; Kim, Hyo-Soo

    2016-06-27

    This study sought to perform a systematic review and network meta-analysis to compare the relative safety and efficacy of contemporary DES and BVS. To improve outcomes of patients undergoing percutaneous coronary revascularization, there have been advances in the design of drug-eluting stents (DES), including the development of drug-eluting bioresorbable vascular scaffolds (BVS). Prospective, randomized, controlled trials comparing bare-metal stents (BMS), paclitaxel-eluting stents (PES), sirolimus-eluting stents (SES), Endeavor zotarolimus-eluting stents (E-ZES), cobalt-chromium (CoCr) everolimus-eluting stents (EES), platinum-chromium (PtCr)-EES, biodegradable polymer (BP)-EES, Resolute zotarolimus-eluting stents (R-ZES), BP biolimus-eluting stents (BP-BES), hybrid sirolimus-eluting stents (H [Orsiro]-SES), polymer-free sirolimus- and probucol-eluting stents, or BVS were searched in online databases. The primary endpoint was definite or probable stent thrombosis at 1 year. A total of 147 trials including 126,526 patients were analyzed in this study. All contemporary DES were superior to BMS and PES in terms of definite or probable stent thrombosis at 1 year. CoCr-EES, PtCr-EES, and H-SES were associated with significantly lower risk than BVS. CoCr-EES and H-SES were superior to SES and BP-BES. The risk of myocardial infarction was significantly lower with H-SES than with BVS. There were no significant differences regarding all-cause or cardiac mortality. Contemporary devices including BVS showed comparably low risks of repeat revascularization. Contemporary DES, including biocompatible DP-DES, BP-DES, and polymer-free DES, showed a low risk of definite or probable stent thrombosis at 1 year. BVS had an increased risk of device thrombosis compared with CoCr-EES, PtCr-EES, and H-SES. Data from extended follow-up are warranted to confirm the long-term safety of contemporary coronary devices. Copyright © 2016 American College of Cardiology Foundation. Published by

  4. Advantages and disadvantages of biodegradable platforms in drug eluting stents.

    PubMed

    Rodriguez-Granillo, Agustina; Rubilar, Bibiana; Rodriguez-Granillo, Gaston; Rodriguez, Alfredo E

    2011-03-26

    Coronary angioplasty with drug-eluting stent (DES) implantation is currently the most common stent procedure worldwide. Since the introduction of DES, coronary restenosis as well as the incidence of target vessel and target lesion revascularization have been significantly reduced. However, the incidence of very late stent thrombosis beyond the first year after stent deployment has more commonly been linked to DES than to bare-metal stent (BMS) implantation. Several factors have been associated with very late stent thrombosis after DES implantation, such as delayed healing, inflammation, stent mal-apposition and endothelial dysfunction. Some of these adverse events were associated with the presence of durable polymers, which were essential to allow the elution of the immunosuppressive drug in the first DES designs. The introduction of erodable polymers in DES technology has provided the potential to complete the degradation of the polymer simultaneously or immediately after the release of the immunosuppressive drug, after which a BMS remains in place. Several DES designs with biodegradable (BIO) polymers have been introduced in preclinical and clinical studies, including randomized trials. In this review, we analyze the clinical results from 6 observational and randomized studies with BIO polymers and discuss advantages and disadvantages of this new technology.

  5. Risk of stent thrombosis among bare-metal stents, first-generation drug-eluting stents, and second-generation drug-eluting stents: results from a registry of 18,334 patients.

    PubMed

    Tada, Tomohisa; Byrne, Robert A; Simunovic, Iva; King, Lamin A; Cassese, Salvatore; Joner, Michael; Fusaro, Massimiliano; Schneider, Simon; Schulz, Stefanie; Ibrahim, Tareq; Ott, Ilka; Massberg, Steffen; Laugwitz, Karl-Ludwig; Kastrati, Adnan

    2013-12-01

    This study sought to compare the risk of stent thrombosis among patients treated with bare-metal stents (BMS), first-generation drug-eluting stents (G1-DES), and second-generation drug-eluting stents (G2-DES) for a period of 3 years. In patients undergoing coronary stenting, there is a scarcity of long-term follow-up data on cohorts large enough to compare rates of stent thrombosis across the stent generations. A total of 18,334 patients undergoing successful coronary stent implantation from 1998 to 2011 at 2 centers in Munich, Germany, were included in this study. Patients were stratified into 3 groups according to treatment with BMS, G1-DES, and G2-DES. The cumulative incidence of definite stent thrombosis at 3 years was 1.5% with BMS, 2.2% with G1-DES, and 1.0% with G2-DES. On multivariate analysis, G1-DES compared with BMS showed a significantly higher risk of stent thrombosis (odds ratio [OR]: 2.05; 95% confidence interval [CI]: 1.47 to 2.86; p < 0.001). G2-DES were associated with a similar risk of stent thrombosis compared with BMS (OR: 0.82; 95% CI: 0.56 to 1.19; p = 0.30). Beyond 1 year, the risk of stent thrombosis was significantly increased with G1-DES compared with BMS (OR: 4.72; 95% CI: 2.01 to 11.1; p < 0.001), but not with G2-DES compared with BMS (OR: 1.01; 95% CI: 0.32 to 3.25; p = 0.98). In a large cohort of unselected patients undergoing coronary stenting, compared with BMS, there was a significant excess risk of stent thrombosis at 3 years with G1-DES, driven by an increased risk of stent thrombosis events beyond 1 year. G2-DES were associated with a similar risk of stent thrombosis compared with BMS. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  6. The effect of stent coating on stent deliverability: direct randomised comparison of drug eluting and bare metal stents using the same stent platform.

    PubMed

    Siminiak, Tomasz; Link, Rafał; Wołoszyn, Maciej; Kałmucki, Piotr; Baszko, Artur

    2012-01-01

    There is certain experimental and clinical evidence indicating that the covering of bare metal stents (BMS) with drug eluting polymers to produce drug eluting stents (DES) results in increased stent stiffness and modifies the mechanical properties of the stent platform. In addition, it has been speculated that the mechanical performance of DES, compared to BMS, may be related to the type of polymer used to cover stents. We aimed at evaluating the deliverability of DES with a lactate based biodegradable polymer and BMS in patients with stable coronary artery disease in a prospective randomised study. One hundred eleven consecutive patients (age: 36-77, mean 58.8 years) scheduled for routine angioplasty due to stable coronary disease were randomised to receive BMS (Chopin II(TM), Balton, Poland) or paclitaxel eluting stent (Chopin Luc(TM), Balton, Poland) using the same metal platform. Only patients scheduled for angioplasty using the direct implantation technique of a single stent were randomised. The exclusion criteria included patients 〉 80 years, multivessel disease and reference diameter of the target vessel 〉 3.5 mm. In the BMS group (n = 55; 35 males and 20 females), the mean diameter of implanted stents was 3.09 ± 0.40 and the mean length was 11.37 ± 2.80, whereas in the DES group (n = 56; 34 males and 22 females) the mean stent sizes were 3.02 ± 0.34 and 17.90 ± 7.38 mm, respectively (p 〉 0.05 for length). The groups did not significantly differ regarding the frequency of stent implantation to particular coronary vessels. The direct stenting technique was attempted and failed, leading to the stents' implantation after predilatation in five patients in the BMS group and six patients in the DES group. Failure of stent implantation and subsequent implantation of another stent type was observed in no BMS patients and in one DES patient (NS). Although stent covering with lactate based drug eluting polymer may increase its stiffness, it does not affect

  7. Functional Nanoarchitectures For Enhanced Drug Eluting Stents

    NASA Astrophysics Data System (ADS)

    Saleh, Yomna E.; Gepreel, Mohamed A.; Allam, Nageh K.

    2017-01-01

    Different strategies have been investigated to allow for optimum duration and conditions for endothelium healing through the enhancement of coronary stents. In this study, a nanoarchitectured system is proposed as a surface modification for drug eluting stents. Highly oriented nanotubes were vertically grown on the surface of a new Ni-free biocompatible Ti-based alloy, as a potential material for self-expandable stents. The fabricated nanotubes were self-grown from the potential stent substrate, which are also proposed to enhance endothelial proliferation while acting as drug reservoir to hinder Vascular Smooth Muscle Cells (VSMC) proliferation. Two morphologies were synthesized to investigate the effect of structure homogeneity on the intended application. The material was characterized by field-emission scanning electron microscope (FESEM), X-ray diffraction (XRD), Raman spectroscopy, energy dispersive X-ray spectroscopy (EDX), and X-ray photoelectron spectroscopy (XPS). Nanoindentation technique was used to study the mechanical properties of the fabricated material. Cytotoxicity and proliferation studies were performed and compared for the two fabricated nanoarchitectures, versus smooth untextured samples, using in-vitro cultured endothelial cells. Finally, the drug loading capacity was experimentally studied and further supported by computational modeling of the release profile.

  8. Drug eluting stents: To evolve or dissolve?

    PubMed

    Bharadwaj, Prashant; Chadha, D S

    2016-10-01

    Currently, percutaneous coronary intervention (PCI) with drug-eluting stents (DES) is the most commonly employed modality in the treatment of patients with coronary artery disease. PCI has come of age over the last four decades with enormous forays in the technology and drugs which have greatly enhanced its capability. Angioplasty and bare metal stents were plagued by high failure rates on account of restenosis leading to repeat revascularization procedures. Insights into pathophysiology of instent restenosis (ISR) and neointimal hyperplasia triggered the development of DES. The dreamlike remarkable reduction in ISR with DES was enthusiastically welcomed. Soon thereafter emerged the spectre of very late stent thrombosis (VLST) with DES. VLST was a new entity seen predominantly with DES and pathological insights as to the cause was instrumental in the development and efficacy of new generation DES. This review will highlight the evolution and present day DES for coronary interventions.

  9. Advances in drug eluting stents – focus on the Endeavor® zotarolimus stent

    PubMed Central

    Bridges, Jonathan; Cutlip, Donald

    2009-01-01

    Coronary artery disease remains one of the leading causes of death in the United States. Over the last 30 years, the development of coronary artery angioplasty and stenting has drastically reduced mortality during acute coronary syndromes while also reducing symptoms of chronic coronary artery disease. Unfortunately, the placement of stents in a coronary artery can be complicated by in-stent thrombosis or restenosis. In 2003–2004, a new generation of stents was introduced to the market with the goal of reducing the rate of restenosis. These stents, called drug eluting stents (DES), are coated with a pharmacological agent designed to reduce the neointimal hyperplasia associated with restenosis. Within a year, approximately 80% of all percutaneous coronary interventions performed within the US involved placement of a DES. In 2006, a controversy arose about the possibility of a statistically significant increased risk of acute stent thrombosis associated with DES especially when used for an “off label” indication. This risk was attributed to delayed endothelization. This controversy has led to a reduction in the use of DES along with longer use of dual platelet inhibition with aspirin and clopidogrel. Recently Medtronic introduced a new DES to the market called the Endeavor® stent – a zotarolimus eluting stent. PMID:22915908

  10. Comparison of the Efficacy of Everolimus-Eluting Stents Versus Drug-Eluting Balloons in Patients With In-Stent Restenosis (from the RIBS IV and V Randomized Clinical Trials).

    PubMed

    Alfonso, Fernando; Pérez-Vizcayno, María José; García Del Blanco, Bruno; García-Touchard, Arturo; Masotti, Mónica; López-Minguez, José R; Iñiguez, Andrés; Zueco, Javier; Velazquez, Maite; Cequier, Angel; Lázaro-García, Rosa; Martí, Vicens; Moris, César; Urbano-Carrillo, Cristobal; Bastante, Teresa; Rivero, Fernando; Cárdenas, Alberto; Gonzalo, Nieves; Jiménez-Quevedo, Pilar; Fernández, Cristina

    2016-02-15

    Treatment of patients with in-stent restenosis (ISR) remains a challenge. This study sought to compare the efficacy of everolimus-eluting stents (EESs) and drug-eluting balloons (DEBs) with paclitaxel in patients with ISR. A pooled analysis of the Restenosis Intra-Stent of Drug-Eluting Stents: Drug-Eluting Balloon vs Everolimus-Eluting Stent (RIBS IV) and Restenosis Intra-Stent of Bare-Metal Stents: Drug-Eluting Balloon vs Everolimus-Eluting Stent (RIBS V) randomized trials was performed using patient-level data. In both trials, EESs were compared with DEBs in patients with ISR (RIBS V included 189 patients with bare-metal ISR; RIBS IV included 309 patients with drug-eluting ISR). Inclusion and exclusion criteria were identical in both trials. A total of 249 patients were allocated to EES and 249 to DEB. Clinical follow-up at 1 year was obtained in all (100%) patients and late angiography (median 249 days) in 91% of eligible patients. Compared with patients treated with DEBs, patients treated with EESs obtained better short-term results (postprocedural minimal lumen diameter 2.28 ± 0.5 vs 2.12 ± 0.4 mm, p <0.0001). At follow-up, patients treated with EESs had larger in-segment minimal lumen diameter (primary end point 2.16 ± 0.7 vs 1.88 ± 0.6 mm, p <0.0001; absolute mean difference 0.28 mm; 95% confidence interval [CI] 0.16 to 0.40) and net lumen gain (1.33 ± 0.6 vs 1.00 ± 0.7 mm, p <0.0001) and had lower %diameter stenosis (19 ± 21% vs 28 ± 22%, p <0.0001) and binary restenosis rate (8.7% vs 15.7%, p = 0.02). Consistent results were observed in the in-lesion analysis. No interactions were found between the underlying stent type and treatment effects. At 1-year clinical follow-up, the composite of cardiac death, myocardial infarction, and target vessel revascularization was significantly reduced in the EES arm (8.8% vs 14.5%, p = 0.03; hazard ratio 0.59, 95% CI 0.31 to 0.94) mainly driven by a lower need for target vessel revascularization (6% vs 12.4%, p

  11. Hybrid coronary revascularization in the era of drug-eluting stents.

    PubMed

    Murphy, Gavin J; Bryan, Alan J; Angelini, Gianni D

    2004-11-01

    Left internal mammary artery to left anterior descending coronary artery bypass grafting integrated with percutaneous coronary angioplasty (hybrid procedure) offers multivessel revascularization with minimal morbidity in high-risk patients. This is caused in part by the avoidance of cardiopulmonary bypass-related morbidity and manipulation of the aorta coupled with minimally invasive techniques. Hybrid revascularization is currently reserved for particularly high-risk patients or those with favorable anatomic variants however, largely because of the emergence of off-pump coronary artery bypass grafting, which permits more complete multivessel revascularization, with low morbidity in high-risk groups. The wider introduction of hybrid revascularization is limited chiefly by the high number of repeat interventions compared with off-pump coronary artery bypass grafting, which occurs because of the target vessel failure rate of percutaneous coronary intervention. Other demerits are the costs and logistic problems associated with performing two procedures with differing periprocedural management protocols. Recently, drug-eluting stents have reduced the need for repeat intervention after percutaneous coronary intervention, and this has raised the possibility that the results of hybrid revascularization may now equal or even better those of off-pump coronary artery bypass grafting. Although undoubtedly effective at reducing in-stent restenosis, drug-eluting stents will not address the issues of incomplete revascularization or the logistic problems associated with hybrid. Uncertainty regarding the long-term effectiveness of drug-eluting stents in many patients, as well as their high cost when compared with those of off-pump coronary artery bypass grafting surgery, also militates against the wider introduction of hybrid revascularization.

  12. Everolimus-Eluting Stents in Patients With Bare-Metal and Drug-Eluting In-Stent Restenosis: Results From a Patient-Level Pooled Analysis of the RIBS IV and V Trials.

    PubMed

    Alfonso, Fernando; Pérez-Vizcayno, María José; García Del Blanco, Bruno; García-Touchard, Arturo; López-Mínguez, José-Ramón; Masotti, Mónica; Zueco, Javier; Melgares, Rafael; Mainar, Vicente; Moreno, Raul; Domínguez, Antonio; Sanchís, Juan; Bethencourt, Armando; Moreu, José; Cequier, Angel; Martí, Vicens; Otaegui, Imanol; Bastante, Teresa; Gonzalo, Nieves; Jiménez-Quevedo, Pilar; Cárdenas, Alberto; Fernández, Cristina

    2016-07-01

    Treatment of patients with drug-eluting stent (DES) in-stent restenosis (ISR) is more challenging than that of patients with bare-metal stent ISR. However, the results of everolimus-eluting stents (EES) in these distinct scenarios remain unsettled. A pooled analysis of the RIBS IV (Restenosis Intra-Stent of Drug-Eluting Stents: Paclitaxel-Eluting Balloon vs Everolimus-Eluting Stent) and RIBS V (Restenosis Intra-Stent of Bare Metal Stents: Paclitaxel-Eluting Balloon vs Everolimus-Eluting Stent) randomized trials was performed using patient-level data to compare the efficacy of EES in bare-metal stent ISR and DES-ISR. Inclusion and exclusion criteria were identical in both trials. Results of 94 patients treated with EES for bare-metal stent ISR were compared with those of 155 patients treated with EES for DES-ISR. Baseline characteristics were more adverse in patients with DES-ISR, although they presented later and more frequently with a focal pattern. After intervention, minimal lumen diameter (2.22±0.5 versus 2.38±0.5 mm, P=0.01) was smaller in the DES-ISR group. Late angiographic findings (89.3% of eligible patients), including minimal lumen diameter (2.03±0.7 versus 2.36±0.6 mm, P<0.001) and diameter stenosis (23±22 versus 13±17%, P<0.001) were poorer in patients with DES-ISR. Results were consistent in the in-segment and in-lesion analyses. On multiple linear regression analysis, minimal lumen diameter at follow-up remained significantly smaller in patients with DES-ISR. Finally, at 1-year clinical follow-up (100% of patients), mortality (2.6 versus 0%, P<0.01) and need for target vessel revascularization (8 versus 2%, P=0.03) were higher in the DES-ISR group. This patient-level pooled analysis of the RIBS IV and RIBS V randomized clinical trials suggests that EES provide favorable outcomes in patients with ISR. However, the results of EES are less satisfactory in patients with DES-ISR than in those with bare-metal stent ISR. URL: http

  13. Mechanisms and Patterns of Intravascular Ultrasound In-Stent Restenosis Among Bare Metal Stents and First- and Second-Generation Drug-Eluting Stents.

    PubMed

    Goto, Kosaku; Zhao, Zhijing; Matsumura, Mitsuaki; Dohi, Tomotaka; Kobayashi, Nobuaki; Kirtane, Ajay J; Rabbani, LeRoy E; Collins, Michael B; Parikh, Manish A; Kodali, Susheel K; Leon, Martin B; Moses, Jeffrey W; Mintz, Gary S; Maehara, Akiko

    2015-11-01

    The most common causes of in-stent restenosis (ISR) are intimal hyperplasia and stent under expansion. The purpose of this study was to use intravascular ultrasound (IVUS) to compare the ISR mechanisms of bare metal stents (BMS), first-generation drug-eluting stents (DES), and second-generation DES. There were 298 ISR lesions including 52 BMS, 73 sirolimus-eluting stents, 52 paclitaxel-eluting stents, 16 zotarolimus-eluting stents, and 105 everolimus-eluting stent. Mean patient age was 66.6 ± 1.1 years, 74.2% were men, and 48.3% had diabetes mellitus. BMS restenosis presented later (70.0 ± 66.7 months) with more intimal hyperplasia compared with DES (BMS 58.6 ± 15.5%, first-generation DES 52.6 ± 20.9%, second-generation DES 48.2 ± 22.2%, p = 0.02). Although reference lumen areas were similar in BMS and first- and second-generation DES, restenotic DES were longer (BMS 21.8 ± 13.5 mm, first-generation DES 29.4 ± 16.1 mm, second-generation DES 32.1 ± 18.7 mm, p = 0.003), and stent areas were smaller (BMS 7.2 ± 2.4 mm(2), first-generation DES 6.1 ± 2.1 mm(2), second-generation DES 5.7 ± 2.0 mm(2), p <0.001). Stent fracture was seen only in DES (first-generation DES 7 [5.0%], second-generation DES 8 [7.4%], p = 0.13). In conclusion, restenotic first- and second-generation DES were characterized by less neointimal hyperplasia, smaller stent areas, longer stent lengths, and more stent fractures than restenotic BMS. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Solving the Issue of Restenosis After Stenting of Intracranial Stenoses: Experience with Two Thin-Strut Drug-Eluting Stents (DES)—Taxus Element™ and Resolute Integrity™

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurre, Wiebke, E-mail: wiebke.kurre@gmx.de; Aguilar-Pérez, Marta; Fischer, Sebastian

    PurposeThin-strut, flexible DES are suitable for intracranial stenting and may improve long-term vessel patency. The purpose of this study was to report our experience with two new-generation DES for the treatment of intracranial atherosclerotic disease.Patients and MethodsWe retrospectively reviewed all patients treated with Taxus Element™ or Resolute Integrity™ stent for an intracranial atherosclerotic stenosis between March 2011 and August 2013. Technical success was defined as the ability to deploy the device at the desired location and reduce the degree of stenosis below 50 %. All procedure-related strokes were recorded. Control angiography was scheduled after 6 weeks, 3, 6, and 12 months and yearlymore » thereafter. A luminal narrowing ≥50 % was regarded as a restenosis. Stroke recurrence in the territory of the treated artery was reported.ResultsIn the defined period we treated 101 patients harboring 117 intracranial stenoses. The procedure was successful in 100 (85.5 %) lesions. Procedure-related strokes occurred in 10 (9.9 %) patients with a permanent morbidity in 3 (3.0 %). Follow-up angiography was available for 83 of 100 (83.0 %) successfully treated lesions with an average of 355 days (IQR 153–482 days). Three (3.6 %) asymptomatic restenoses were detected. All occurred after treatment with Resolute Integrity™, none after Taxus Element™ (p = 0.059). New strokes in the territory of the treated artery were encountered in 2 (2.6 %) occasions.ConclusionThin-strut DES improve long-term patency and reduce the risk of subsequent stroke. Differences between devices may exist. Feasibility is comparable to bare-metal balloon-mounted stents and procedure-related strokes occurred within the expected range.« less

  15. Endothelial cell repopulation after stenting determines in-stent neointima formation: effects of bare-metal vs. drug-eluting stents and genetic endothelial cell modification.

    PubMed

    Douglas, Gillian; Van Kampen, Erik; Hale, Ashley B; McNeill, Eileen; Patel, Jyoti; Crabtree, Mark J; Ali, Ziad; Hoerr, Robert A; Alp, Nicholas J; Channon, Keith M

    2013-11-01

    Understanding endothelial cell repopulation post-stenting and how this modulates in-stent restenosis is critical to improving arterial healing post-stenting. We used a novel murine stent model to investigate endothelial cell repopulation post-stenting, comparing the response of drug-eluting stents with a primary genetic modification to improve endothelial cell function. Endothelial cell repopulation was assessed en face in stented arteries in ApoE(-/-) mice with endothelial-specific LacZ expression. Stent deployment resulted in near-complete denudation of endothelium, but was followed by endothelial cell repopulation, by cells originating from both bone marrow-derived endothelial progenitor cells and from the adjacent vasculature. Paclitaxel-eluting stents reduced neointima formation (0.423 ± 0.065 vs. 0.240 ± 0.040 mm(2), P = 0.038), but decreased endothelial cell repopulation (238 ± 17 vs. 154 ± 22 nuclei/mm(2), P = 0.018), despite complete strut coverage. To test the effects of selectively improving endothelial cell function, we used transgenic mice with endothelial-specific overexpression of GTP-cyclohydrolase 1 (GCH-Tg) as a model of enhanced endothelial cell function and increased NO production. GCH-Tg ApoE(-/-) mice had less neointima formation compared with ApoE(-/-) littermates (0.52 ± 0.08 vs. 0.26 ± 0.09 mm(2), P = 0.039). In contrast to paclitaxel-eluting stents, reduced neointima formation in GCH-Tg mice was accompanied by increased endothelial cell coverage (156 ± 17 vs. 209 ± 23 nuclei/mm(2), P = 0.043). Drug-eluting stents reduce not only neointima formation but also endothelial cell repopulation, independent of strut coverage. In contrast, selective targeting of endothelial cell function is sufficient to improve endothelial cell repopulation and reduce neointima formation. Targeting endothelial cell function is a rational therapeutic strategy to improve vascular healing and decrease neointima formation after stenting.

  16. Cost-effectiveness of drug-eluting stents in patients at high or low risk of major cardiac events in the Basel Stent KostenEffektivitäts Trial (BASKET): an 18-month analysis.

    PubMed

    Brunner-La Rocca, Hans Peter; Kaiser, Christoph; Bernheim, Alain; Zellweger, Michael J; Jeger, Raban; Buser, Peter T; Osswald, Stefan; Pfisterer, Matthias

    2007-11-03

    Our aim was to determine whether drug-eluting stents are good value for money in long-term, everyday practice. We did an 18-month cost-effectiveness analysis of the Basel Stent KostenEffektivitäts Trial (BASKET), which randomised 826 patients 2:1 to drug-eluting stents (n=545) or to bare-metal stents (281). We used non-parametric bootstrap techniques to determine incremental cost-effectiveness ratios (ICERs) of drug-eluting versus bare-metal stents, to compare low-risk (> or =3.0 mm stents in native vessels; n=558, 68%) and high-risk patients (<3.0 mm stents/bypass graft stenting; n=268, 32%), and to do sensitivity analyses by altering costs and event rates in the whole study sample and in predefined subgroups. Quality-adjusted life-years (QALYs) were assessed by EQ-5D questionnaire (available in 703/826 patients). Overall costs were higher for patients with drug-eluting stents than in those with bare-metal stents (11,808 euros [SD 400] per patient with drug-eluting stents and 10,450 euros [592] per patient with bare-metal stents, mean difference 1358 euros [717], p<0.0001), due to higher stent costs. We calculated an ICER of 64,732 euros to prevent one major adverse cardiac event, and of 40,467 euros per QALY gained. Stent costs, number of events, and QALYs affected ICERs most, but unrealistic alterations would have been required to achieve acceptable cost-effectiveness. In low-risk patients, the probability of drug-eluting stents achieving an arbitrary ICER of 10,000 euros or less to prevent one major adverse cardiac event was 0.016; by contrast, it was 0.874 in high-risk patients. If used in all patients, drug-eluting stents are not good value for money, even if prices were substantially reduced. Drug-eluting stents are cost effective in patients needing small vessel or bypass graft stenting, but not in those who require large native vessel stenting.

  17. Impact of coronary artery calcification in percutaneous coronary intervention with paclitaxel-eluting stents: Two-year clinical outcomes of paclitaxel-eluting stents in patients from the ARRIVE program.

    PubMed

    Lee, Michael S; Yang, Tae; Lasala, John; Cox, David

    2016-11-15

    The purpose of this study was to evaluate clinical outcomes after percutaneous coronary intervention (PCI) in patients with coronary artery calcification (CAC). Smaller studies have reported worse clinical outcomes in patients with CAC who undergo PCI. The impact of CAC in the drug-eluting stent era is unclear. Data from 7,492 patients treated by PCI with ≥1 TAXUS Express stent in the ARRIVE registry with no inclusion/exclusion criteria were stratified by the severity of CAC, as determined by the operator. Endpoints were independently adjudicated. All major adverse cardiac events were assessed at 2 years. Moderate/severe CAC was present in 19.6%. The nil/mild CAC group had higher rate of current smokers. The moderate/severe CAC group was older and had a higher prevalence of hypertension, kidney disease, prior coronary artery bypass grafting, congestive heart failure, and left main disease. After adjustment for imbalanced baseline variables, patients with moderate/severe CAC had higher 2 year rates of major adverse cardiac events (18.3% vs 13.5%, p = 0.01) and death (10.3% vs 5.6%, p = 0.02). Moderate/severe CAC was associated with increased clinical events in patients who underwent PCI with TAXUS stents. This may be explained in part due to differences important baseline characteristics including more patients with more comorbidities and more complex lesions. After adjustment for imbalanced baseline variables, the moderate/severe CAC group had a higher risk of major adverse cardiac events and death. Improvements in treatment strategies are needed for this high-risk group of patients who undergo PCI. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  18. Ultrathin, bioresorbable polymer sirolimus-eluting stents versus thin, durable polymer everolimus-eluting stents in patients undergoing coronary revascularisation (BIOFLOW V): a randomised trial.

    PubMed

    Kandzari, David E; Mauri, Laura; Koolen, Jacques J; Massaro, Joseph M; Doros, Gheorghe; Garcia-Garcia, Hector M; Bennett, Johan; Roguin, Ariel; Gharib, Elie G; Cutlip, Donald E; Waksman, Ron

    2017-10-21

    The development of coronary drug-eluting stents has included use of new metal alloys, changes in stent architecture, and use of bioresorbable polymers. Whether these advancements improve clinical safety and efficacy has not been shown in previous randomised trials. We aimed to examine the clinical outcomes of a bioresorbable polymer sirolimus-eluting stent compared with a durable polymer everolimus-eluting stent in a broad patient population undergoing percutaneous coronary intervention. BIOFLOW V was an international, randomised trial done in patients undergoing elective and urgent percutaneous coronary intervention in 90 hospitals in 13 countries (Australia, Belgium, Canada, Denmark, Germany, Hungary, Israel, the Netherlands, New Zealand, South Korea, Spain, Switzerland, and the USA). Eligible patients were those aged 18 years or older with ischaemic heart disease undergoing planned stent implantation in de-novo, native coronary lesions. Patients were randomly assigned (2:1) to either an ultrathin strut (60 μm) bioresorbable polymer sirolimus-eluting stent or to a durable polymer everolimus-eluting stent. Randomisation was via a central web-based data capture system (mixed blocks of 3 and 6), and stratified by study site. The primary endpoint was 12-month target lesion failure. The primary non-inferiority comparison combined these data from two additional randomised trials of bioresorbable polymer sirolimus-eluting stent and durable polymer everolimus-eluting stent with Bayesian methods. Analysis was by intention to treat. The trial is registered with ClinicalTrials.gov, number NCT02389946. Between May 8, 2015, and March 31, 2016, 4772 patients were recruited into the study. 1334 patients met inclusion criteria and were randomly assigned to treatment with bioresorbable polymer sirolimus-eluting stents (n=884) or durable polymer everolimus-eluting stents (n=450). 52 (6%) of 883 patients in the bioresorbable polymer sirolimus-eluting stent group and 41 (10%) of

  19. The application of ink-jet technology for the coating and loading of drug-eluting stents.

    PubMed

    Tarcha, Peter J; Verlee, Donald; Hui, Ho Wah; Setesak, Jeff; Antohe, Bogdan; Radulescu, Delia; Wallace, David

    2007-10-01

    The combination of drugs with devices, where locally delivered drugs elute from the device, has demonstrated distinct advantages over therapies involving systemic or local drugs and devices administered separately. Drug-eluting stents are most notable. Ink jet technology offers unique advantages for the coating of very small medical devices with drugs and drug-coating combinations, especially in cases where the active pharmaceutical agent is very expensive to produce and wastage is to be minimized. For medical devices such as drug-containing stents, the advantages of ink-jet technology result from the controllable and reproducible nature of the droplets in the jet stream and the ability to direct the stream to exact locations on the device surfaces. Programmed target deliveries of 100 microg drug, a typical dose for a small stent, into cuvettes gave a standard deviation (SD) of dose of 0.6 microg. Jetting on coated, uncut stent tubes exhibited 100% capture efficiency with a 1.8 microg SD for a 137 microg dose. In preliminary studies, continuous jetting on stents can yield efficiencies up to 91% and coefficients of variation as low as 2%. These results indicate that ink-jet technology may provide significant improvement in drug loading efficiency over conventional coating methods.

  20. Fabrication of balloon-expandable self-lock drug-eluting polycaprolactone stents using micro-injection molding and spray coating techniques.

    PubMed

    Liu, Shih-Jung; Chiang, Fu-Jun; Hsiao, Chao-Ying; Kau, Yi-Chuan; Liu, Kuo-Sheng

    2010-10-01

    The purpose of this report was to develop novel balloon-expandable self-lock drug-eluting poly(ε-caprolactone) stents. To fabricate the biodegradable stents, polycaprolactone (PCL) components were first fabricated by a lab-scale micro-injection molded machine. They were then assembled and hot-spot welded into mesh-like stents of 3 and 5 mm in diameters. A special geometry of the components was designed to self-lock the assembled stents and to resist the external pressure of the blood vessels after being expanded by balloons. Characterization of the biodegradable PCL stents was carried out. PCL stents exhibited comparable mechanical property to that of metallic stents. No significant collapse pressure reduction and weight loss of the stents were observed after being submerged in PBS for 12 weeks. In addition, the developed stent was coated with paclitaxel by a spray coating technique and the release characteristic of the drug was determined by an in vitro elution method. The high-performance liquid chromatography analysis showed that the biodegradable stents could release a high concentration of paclitaxel for more than 60 days. By adopting the novel techniques, we will be able to fabricate biodegradable drug-eluting PCL stents of different sizes for various cardiovascular applications.

  1. Outcomes with various drug eluting or bare metal stents in patients with diabetes mellitus: mixed treatment comparison analysis of 22 844 patient years of follow-up from randomised trials

    PubMed Central

    Kumar, Sunil; Fusaro, Mario; Amoroso, Nicholas; Kirtane, Ajay J; Byrne, Robert A; Williams, David O; Slater, James; Cutlip, Donald E; Feit, Frederick

    2012-01-01

    Objectives To evaluate the efficacy and safety of currently used drug eluting stents compared with each other and compared with bare metal stents in patients with diabetes. Design Mixed treatment comparison meta-analysis. Data sources and study selection PubMed, Embase, and CENTRAL were searched for randomised clinical trials, until April 2012, of four durable polymer drug eluting stents (sirolimus eluting stents, paclitaxel eluting stents, everolimus eluting stents, and zotarolimus eluting stents) compared with each other or with bare metal stents for the treatment of de novo coronary lesions and enrolling at least 50 patients with diabetes. Primary outcomes Efficacy (target vessel revascularisation) and safety (death, myocardial infarction, stent thrombosis). Results From 42 trials with 22 844 patient years of follow-up, when compared with bare metal stents (reference rate ratio 1) all of the currently used drug eluting stents were associated with a significant reduction in target vessel revascularisation (37% to 69%), though the efficacy varied with the type of stent (everolimus eluting stents∼sirolimus eluting stents>paclitaxel eluting stents∼zotarolimus eluting stent>bare metal stents). There was about an 87% probability that everolimus eluting stents were the most efficacious compared with all others, though there were limited usable data for the zotarolimus eluting Resolute stent in patients with diabetes. Moreover, there was no increased risk of any safety outcome (including very late stent thrombosis) with any drug eluting stents compared with bare metal stents. There was about a 62% probability that the everolimus eluting stent was the safest stent for the outcome of “any” stent thrombosis. Conclusions Among patients with diabetes treated with coronary stents all currently available drug eluting stents were efficacious without compromising safety compared with bare metal stents. There were relative differences among the drug eluting stents, such

  2. Long-Term Results of Everolimus-Eluting Stents Versus Drug-Eluting Balloons in Patients With Bare-Metal In-Stent Restenosis: 3-Year Follow-Up of the RIBS V Clinical Trial.

    PubMed

    Alfonso, Fernando; Pérez-Vizcayno, María José; García Del Blanco, Bruno; Otaegui, Imanol; Masotti, Mónica; Zueco, Javier; Veláquez, Maite; Sanchís, Juan; García-Touchard, Arturo; Lázaro-García, Rosa; Moreu, José; Bethencourt, Armando; Cuesta, Javier; Rivero, Fernando; Cárdenas, Alberto; Gonzalo, Nieves; Jiménez-Quevedo, Pilar; Fernández, Cristina

    2016-06-27

    The aim of this study was to compare the long-term efficacy of everolimus-eluting stents (EES) and drug-eluting balloons (DEB) in patients with bare-metal stent in-stent restenosis (ISR). The relative long-term clinical efficacy of current therapeutic modalities in patients with ISR remains unknown. The 3-year clinical follow-up (pre-specified endpoint) of patients included in the RIBS V (Restenosis Intra-Stent of Bare-Metal Stents: Drug-Eluting Balloon vs Everolimus-Eluting Stent Implantation) randomized clinical trial was analyzed. All patients were followed yearly using a pre-defined structured questionnaire. A total of 189 patients with bare-metal stent ISR were allocated to either EES (n = 94) or DEB (n = 95). Clinical follow-up at 1, 2, and 3 years was obtained in all patients (100%). Compared with patients treated with DEB, those treated with EES obtained better angiographic results, including larger minimal luminal diameter at follow-up (primary study endpoint; 2.36 ± 0.6 mm vs. 2.01 ± 0.6 mm; p < 0.001). At 3 years, the rates of cardiac death (2% vs. 1%), myocardial infarction (4% vs. 5%) and target vessel revascularization (9% vs. 5%) were similar in the DEB and EES arms. Importantly, however, at 3 years, the rate of target lesion revascularization was significantly lower in the EES arm (2% vs. 8%; p = 0.04; hazard ratio: 0.23; 95% confidence interval: 0.06 to 0.93). The need for "late" (>1 year) target vessel (3 [3.2%] vs. 3 [3.2%]; p = 0.95) and target lesion (1 [1%] vs. 2 [2.1%]; p = 0.54) revascularization was low and similar in the 2 arms. Rates of definite or probable stent thrombosis (1% vs. 0%) were also similar in the 2 arms. The 3-year clinical follow-up of the RIBS V clinical trial confirms the sustained safety and efficacy of EES and DEB in patients treated for bare-metal stent ISR. In this setting, EES reduce the need for target lesion revascularization at very long-term follow-up. (RIBS V [Restenosis Intra-Stent of Bare Metal Stents

  3. Application of rotational atherectomy in the drug-eluting stent era

    PubMed Central

    Chen, Chun-Chi; Hsieh, I-Chang

    2013-01-01

    Rotational atherectomy (RA) was introduced in the interventional arena in 1988 as a dedicated device for calcified lesions. Due to the complexity of the technique, the development of alternative methods such as the cutting balloon procedure, and the high restenosis rate of subsequent bare metal stenting in long lesions, its use had later declined. However, with the increasing use of drug-eluting stents (DES) and the aggressive treatment of longer lesions, the number of procedure performed with RA has increased significantly again in recent years. In this article, we reviewed the application of RA in DES era. PMID:24133506

  4. Predictors and Long-Term Clinical Impact of Acute Stent Malapposition: An Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents (ADAPT-DES) Intravascular Ultrasound Substudy.

    PubMed

    Wang, Bin; Mintz, Gary S; Witzenbichler, Bernhard; Souza, Cristiano F; Metzger, D Christopher; Rinaldi, Michael J; Duffy, Peter L; Weisz, Giora; Stuckey, Thomas D; Brodie, Bruce R; Matsumura, Mitsuaki; Yamamoto, Myong-Hwa; Parvataneni, Rupa; Kirtane, Ajay J; Stone, Gregg W; Maehara, Akiko

    2016-12-22

    The impact of acute stent malapposition (ASM) on long-term clinical outcomes in patients undergoing percutaneous coronary intervention is still controversial. We sought to evaluate predictors and long-term clinical outcomes of ASM. ADAPT-DES (Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents) was a prospective multicenter study of 8663 patients undergoing percutaneous coronary intervention using drug-eluting stents. In a prespecified intravascular ultrasound-guided substudy, 2072 patients with 2446 culprit lesions had post-percutaneous coronary intervention intravascular ultrasound and were classified according to the presence or absence of ASM. After intravascular ultrasound-guided percutaneous coronary intervention, the overall prevalence of ASM after successful drug-eluting stents implantation was 14.4% per patient and 12.6% per lesion. Compared to lesions without ASM, lesions with ASM had larger in-stent lumen areas, larger stent areas, and larger in-stent vessel areas. A larger mean plaque area along with more attenuated plaque was observed in lesions with ASM versus lesions without ASM. Lesions with ASM had greater proximal and distal reference lumen areas and more distal, but not proximal, reference calcium compared to lesions without ASM. At 2-year follow-up, there was no significant difference in the incidence of cardiac death; myocardial infarction; early, late, or very late stent thrombosis; or clinically driven target lesion revascularization in patients with ASM versus those without ASM. Furthermore, ASM was not an independent predictor of 2-year major adverse cardiac events or target lesion revascularization even when forced into the multivariate model. In patients treated with intravascular ultrasound-guided drug-eluting stents implantation, ASM was not associated with adverse clinical events during long-term follow-up including, but not limited to, stent thrombosis. URL: https://www.clinicaltrials.gov. Unique identifier: NCT00638794

  5. gender-specific outcome after paclitaxel-eluting stent implantation in japanese patients with coronary artery disease--sub-analysis of the Japan TAXUS Express2 post-marketing survey.

    PubMed

    Okura, Hiroyuki; Nakamura, Masato; Kotani, Jun-Ichi; Kozuma, Ken

    2013-01-01

     Although previous randomized and non-randomized studies have demonstrated the safety and efficacy of paclitaxel-eluting stents (PES), a higher revascularization rate has been reported in women than in men. A sub-analysis of the TAXUS Japan Post-market Surveillance Study (TAXUS-PMS) was done to assess the influence of gender on clinical outcome.  A total of 2,132 PES-treated Japanese patients (women, n=551) from this registry were analyzed. Subjects were stratified by gender to compare 1-year clinical outcome. PES-treated women were older and more likely to have insulin-treated diabetes and hypertension. In contrast, PES-treated men were more likely to be smokers, have a previous history of myocardial infarction, and lower ejection fraction. While cardiac death, myocardial infarction and stent thrombosis were similar between men and women, major cardiac events tended to be lower in women than in men (6.4% vs. 8.8%, P=0.08). Although women had significantly smaller reference vessel size (2.46±0.53 mm vs. 2.59±0.60 mm, P<0.0001), the restenosis rate tended to be lower in women than in men (11.5% vs. 14.8%, P=0.11). Subsequently, the target lesion revascularization rate was significantly lower in women than in men (4.2% vs. 6.5%, P<0.05).  Despite a higher risk profile, Japanese women treated with PES did not have a higher rate of repeat revascularization or major adverse clinical outcome than PES-treated men at 1 year. 

  6. Sirolimus- versus paclitaxel-eluting stents in patients with stenosis in a native coronary artery.

    PubMed

    Doggrell, Sheila A

    2004-06-01

    With stenting, restenosis occurs in approximately 25% of patients and the incidence is even higher in patients with diabetes, small coronary vessels and long lesions. The sirolimus-eluting balloon-expandable stent in the treatment of patients with de novo native coronary-artery lesions (SIRIUS) trial, enrolled patients with more challenging conditions, including a higher frequency of diabetes, more complex lesion morphology and longer lesions and showed benefits in all groups. After 240 days, the frequency of stenosis of at least 50% of the luminal diameter was 3.2 and 35.4% in the sirolimus and standard stents groups, respectively. The TAXUS-IV trial was the first large-scale trial on the safety and efficacy of paclitaxel-eluting stents in a broad population of patients and lesions, and established the safety and effectiveness of this agent. After 9 months, there was a mean stenosis of 17% in the paclitaxel group compared to 37% of patients treated with a bare stent. Thus, the local delivery of potent cell cycle inhibitors (sirolimus, paclitaxel) from stents being used for revascularisation dramatically decreases the incidence of restenosis in the populations of patients studied so far and represents a major advancement in the treatment of coronary artery disease.

  7. Pore networks and polymer rearrangement on a drug-eluting stent as revealed by correlated confocal Raman and atomic force microscopy.

    PubMed

    Biggs, Kevin B; Balss, Karin M; Maryanoff, Cynthia A

    2012-05-29

    Drug release from and coating morphology on a CYPHER sirolimus-eluting coronary stent (SES) during in vitro elution were studied by correlated confocal Raman and atomic force microscopy (CRM and AFM, respectively). Chemical surface and subsurface maps of the SES were generated in the same region of interest by CRM and were correlated with surface topography measured by AFM at different elution times. For the first time, a direct correlation between drug-rich regions and the coating morphology was made on a drug-eluting medical device, linking drug release with pore formation, pore throats, and pore networks. Drug release was studied on a drug-eluting stent (DES) system with a multicomponent carrier matrix (poly(n-butyl methacrylate) [PBMA] and poly(ethylene-co-vinyl acetate) [PEVA]). The polymer was found to rearrange postelution because confluence of the carrier polymer matrix reconstituted the voids created by drug release.

  8. Nanoparticle Drug- and Gene-eluting Stents for the Prevention and Treatment of Coronary Restenosis

    PubMed Central

    Yin, Rui-Xing; Yang, De-Zhai; Wu, Jin-Zhen

    2014-01-01

    Percutaneous coronary intervention (PCI) has become the most common revascularization procedure for coronary artery disease. The use of stents has reduced the rate of restenosis by preventing elastic recoil and negative remodeling. However, in-stent restenosis remains one of the major drawbacks of this procedure. Drug-eluting stents (DESs) have proven to be effective in reducing the risk of late restenosis, but the use of currently marketed DESs presents safety concerns, including the non-specificity of therapeutics, incomplete endothelialization leading to late thrombosis, the need for long-term anti-platelet agents, and local hypersensitivity to polymer delivery matrices. In addition, the current DESs lack the capacity for adjustment of the drug dose and release kinetics appropriate to the disease status of the treated vessel. The development of efficacious therapeutic strategies to prevent and inhibit restenosis after PCI is critical for the treatment of coronary artery disease. The administration of drugs using biodegradable polymer nanoparticles as carriers has generated immense interest due to their excellent biocompatibility and ability to facilitate prolonged drug release. Despite the potential benefits of nanoparticles as smart drug delivery and diagnostic systems, much research is still required to evaluate potential toxicity issues related to the chemical properties of nanoparticle materials, as well as to their size and shape. This review describes the molecular mechanism of coronary restenosis, the use of DESs, and progress in nanoparticle drug- or gene-eluting stents for the prevention and treatment of coronary restenosis. PMID:24465275

  9. Modifying effect of dual antiplatelet therapy on incidence of stent thrombosis according to implanted drug-eluting stent type.

    PubMed

    Camenzind, Edoardo; Boersma, Eric; Wijns, William; Mauri, Laura; Rademaker-Havinga, Tessa; Ordoubadi, Farzin Fath; Suttorp, Maarten J; Al Kurdi, Mohammad; Steg, Ph Gabriel

    2014-08-01

    To investigate the putative modifying effect of dual antiplatelet therapy (DAPT) use on the incidence of stent thrombosis at 3 years in patients randomized to Endeavor zotarolimus-eluting stent (E-ZES) or Cypher sirolimus-eluting stent (C-SES). Of 8709 patients in PROTECT, 4357 were randomized to E-ZES and 4352 to C-SES. Aspirin was to be given indefinitely, and clopidogrel/ticlopidine for ≥ 3 months or up to 12 months after implantation. Main outcome measures were definite or probable stent thrombosis at 3 years. Multivariable Cox regression analysis was applied, with stent type, DAPT, and their interaction as the main outcome determinants. Dual antiplatelet therapy adherence remained the same in the E-ZES and C-SES groups (79.6% at 1 year, 32.8% at 2 years, and 21.6% at 3 years). We observed a statistically significant (P = 0.0052) heterogeneity in treatment effect of stent type in relation to DAPT. In the absence of DAPT, stent thrombosis was lower with E-ZES vs. C-SES (adjusted hazard ratio 0.38, 95% confidence interval 0.19, 0.75; P = 0.0056). In the presence of DAPT, no difference was found (1.18; 0.79, 1.77; P = 0.43). A strong interaction was observed between drug-eluting stent type and DAPT use, most likely prompted by the vascular healing response induced by the implanted DES system. These results suggest that the incidence of stent thrombosis in DES trials should not be evaluated independently of DAPT use, and the optimal duration of DAPT will likely depend upon stent type (Clinicaltrials.gov number NCT00476957). Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  10. Preparation of paclitaxel/chitosan co-assembled core-shell nanofibers for drug-eluting stent

    NASA Astrophysics Data System (ADS)

    Tang, Jing; Liu, Yongjia; Zhu, Bangshang; Su, Yue; Zhu, Xinyuan

    2017-01-01

    The paclitaxel/chitosan (PTX/CS) core-shell nanofibers (NFs) are easily prepared by co-assembly of PTX and CS and used in drug-eluting stent. The mixture solution of PTX (dissolved in ethanol) and CS (dissolved in 1% acetic acid water solution) under sonication will make the formation of NFs, in which small molecule PTX co-assembles with biomacromolecular CS through non-covalent interactions. The obtained NFs are tens to hundreds nanometers in diameter and millimeter level in length. Furthermore, the structure of PTX/CS NFs was characterized by confocal laser scanning microscopy (CLSM), zeta potential, X-ray photoelectron spectroscopy (XPS) and nanoscale infra-red (nanoIR), which provided evidences demonstrated that PTX/CS NFs are core-shell structures. The 'shell' of CS wrapped outside of the NFs, while PTX is located in the core. Thus it resulted in high drug loading content (>40 wt.%). The well-controlled drug release, low cytotoxicity and good haemocompatibility were also found in drug carrier system of PTX/CS NFs. In addition, the hydrophilic and flexible properties of NFs make them easily coating and filming on stent to prepare drug-eluting stent (DES). Therefore, this study provides a convenient method to prepare high PTX loaded NFs, which is a promising nano-drug carrier used for DES and other biomedical applications. The possible molecular mechanism of PTX and CS co-assembly and core-shell nanofiber formation is also explored.

  11. Randomized comparison of Zotarolimus-Eluting Endeavor Sprint versus bare-metal stent implantation in uncertain drug-eluting stent candidates: rationale, design, and characterization of the patient population for the Zotarolimus-eluting Endeavor Sprint stent in uncertain DES candidates study.

    PubMed

    Valgimigli, Marco; Patialiakas, Athanasios; Thury, Attila; Colangelo, Salvatore; Campo, Gianluca; Tebaldi, Matteo; Ungi, Imre; Tondi, Stefano; Roffi, Marco; Menozzi, Alberto; de Cesare, Nicoletta; Garbo, Roberto; Meliga, Emanuele; Testa, Luca; Gabriel, Henrique M; Airoldi, Flavio; Ferlini, Marco; Liistro, Francesco; Dellavalle, Antonio; Vranckx, Pascal; Briguori, Carlo

    2013-11-01

    The use of drug-eluting stent (DES) instead of bare-metal stent (BMS) in patients at high stent thrombosis or bleeding risk as well as in those at low restenosis risk (ie, uncertain DES candidates) remains a matter of debate. Zotarolimus-Eluting Endeavor Sprint stent (E-ZES) (Santa Rosa, CA) is a hydrophilic polymer-based second-generation device with unique drug fast-release profile, which may allow for a shorter dual antiplatelet therapy (DAPT) duration without safety concerns. The primary objective is to assess whether E-ZES implantation followed by a shorter than currently recommended course of DAPT will decrease the incidence of 12-month major adverse cardiovascular events as compared with BMS in undefined DES recipients. Actual duration of DAPT regimen will be dictated by patients' characteristics and not by stent type and, as such, can be as short as 30 days after intervention in both stent groups. The ZEUS study is an open-label randomized clinical trial conducted at 20 clinical sites in Italy, Switzerland, Portugal, and Hungary. With 1,600 individuals, this study will have 85% power to detect a 33% difference in the primary end point consisting of the composite of death, nonfatal myocardial infarction, or target vessel revascularization. The ZEUS trial aims to assess whether the use of E-ZES, followed by a DAPT duration regimen based on patients' characteristics and not by stent type, is superior to conventional BMS implantation in undefined DES recipients who qualify for the presence of high thrombosis, bleeding, or low restenosis risk criteria. © 2013.

  12. Factors that affect mass transport from drug eluting stents into the artery wall

    PubMed Central

    2010-01-01

    Coronary artery disease can be treated by implanting a stent into the blocked region of an artery, thus enabling blood perfusion to distal vessels. Minimally invasive procedures of this nature often result in damage to the arterial tissue culminating in the re-blocking of the vessel. In an effort to alleviate this phenomenon, known as restenosis, drug eluting stents were developed. They are similar in composition to a bare metal stent but encompass a coating with therapeutic agents designed to reduce the overly aggressive healing response that contributes to restenosis. There are many variables that can influence the effectiveness of these therapeutic drugs being transported from the stent coating to and within the artery wall, many of which have been analysed and documented by researchers. However, the physical deformation of the artery substructure due to stent expansion, and its influence on a drugs ability to diffuse evenly within the artery wall have been lacking in published work to date. The paper highlights previous approaches adopted by researchers and proposes the addition of porous artery wall deformation to increase model accuracy. PMID:20214774

  13. Drug-eluting stents. Insights from invasive imaging technologies.

    PubMed

    Honda, Yasuhiro

    2009-08-01

    Drug-eluting stents (DES) represent a revolutionary technology in their unique ability to provide both mechanical and biological solutions simultaneously to the target lesion. As a result of biological effects from the pharmacological agents and interaction of DES components with the arterial wall, considerable differences exist between DES and conventional bare metal stents (BMS), yet some of the old lessons learned in the BMS era remain clinically significant. In this context, contrast angiography provides very little information about in vivo device properties and their biomechanical effects on the arterial wall. In contrast, current catheter-based imaging tools, such as intravascular ultrasound, optical coherence tomography, and intracoronary angioscopy can offer unique insights into DES through direct assessment of the device and treated vessel in the clinical setting. This article reviews these insights from current DES with particular focus on performance and safety characteristics as well as discussing an optimal deployment technique, based upon findings obtained through the use of the invasive imaging technologies.

  14. A Bumpy and Winding but Right Path to Domestic Drug-Eluting Coronary Stents

    PubMed Central

    Cho, Jae Yeong; Ahn, Youngkeun

    2013-01-01

    Restenosis and stent thrombosis remain major concerns after percutaneous coronary intervention for the treatment of coronary artery disease. The present review was undertaken in order to highlight the various coronary stents that have been investigated in our Heart Research Center, and how far we have come from the first heparin-coated stent first used in the late 1990s. Thereafter, from the abciximab-coated stent to the current gene-delivery stent and other newer agents, our group has applied a range of techniques in this field. However, in groups similar to ours, the restenosis rates of such stents are still high for second-generation drug-eluting stents (DESs). Moreover, our nation imports almost all of these types of stents from other countries. Thus, we need to develop domestic coronary stents. Research into newer DESs are warranted in Korea so as to achieve improved safety and efficacy outcomes. PMID:24255648

  15. Five-year follow-up of the endothelial progenitor cell capturing stent versus the paxlitaxel-eluting stent in de novo coronary lesions with a high risk of coronary restenosis.

    PubMed

    Woudstra, Pier; Kalkman, Deborah N; Beijk, Marcel A; Klomp, Margo; Damman, Peter; Koch, Karel T; Henriques, Jose P S; Baan, Jan; Vis, Marije M; Piek, Jan J; Tijssen, Jan G P; de Winter, Robbert J

    2018-06-01

    To assess the long-term safety and clinical efficacy of the Genous endothelial progenitor cell capturing stent (ECS) compared with the TAXUS Liberté paclitaxel-eluting stent (PES) in lesions with a high risk of restenosis. Instead of the use of cytotoxic or cytostatic drugs in drug-eluting stents, a "pro-healing" approach in ECS may overcome impeded healing response due to delayed functional endothelialization of the stent struts. In the prospective, randomized TRIAS pilot study 193 patients with coronary artery lesions carrying a high risk of restenosis were included (ECS: n = 98, PES: n = 95). The primary focus of this analysis was target vessel failure (TVF) at 5 years. Dual antiplatelet therapy was prescribed for ≥1 month after ECS and for ≥6 months after PES. At 5 years follow-up, no significant differences were found in TVF (ECS 24% vs. PES 29%, risk difference 95% confidence interval (RDCI) -17.3% to 7.4%). Between 2 and 5 years after the index procedure, low numbers of TVF were observed in ECS compared with PES (ECS 4% vs. PES 16%, RDCI -20.8% to -2.3%). There was no definite stent thrombosis in ECS compared with four patients in the PES group. This is the first randomized study providing very long-term clinical efficacy and safety of the ECS in lesions carrying a high risk of restenosis. At 5 years follow-up, TVF rates in ECS group are numerically lower compared with PES due to an increase of events between 2 and 5 years after the index procedure. © 2017 Wiley Periodicals, Inc.

  16. Stent implantation into the tracheo-bronchial system in rabbits: histopathologic sequelae in bare metal vs. drug-eluting stents.

    PubMed

    Sigler, Matthias; Klötzer, Julia; Quentin, Thomas; Paul, Thomas; Möller, Oliver

    2015-12-01

    Stent implantation into the tracheo-bronchial system may be life-saving in selected pediatric patients with otherwise intractable stenosis of the upper airways. Following implantation, significant tissue proliferation may occur, requiring re-interventions. We sought to evaluate the effect of immunosuppressive coating of the stents on the extent of tissue proliferation in an animal model. Bare metal and sirolimus-coated stents (Bx Sonic and Cypher Select, Johnson & Johnson, Cordis) were implanted into non-stenotic lower airways of New Zealand white rabbits (weight 3.1 to 4.8 kg). Three stents with sirolimus coating and six bare metal stents could be analyzed by means of histology and immunohistochemistry 12 months after implantation. On a macroscopic evaluation, all stents were partially covered with a considerable amount of whitish tissue. Histologically, these proliferations contained fiber-rich connective tissue and some fibromuscular cells without significant differences between both stent types. The superficial tissue layer was formed by typical respiratory epithelium and polygonal cells. Abundant lymphocyte infiltrations and moderate granulocyte infiltrations were found in both groups correspondingly, whereas foreign-body reaction was more pronounced around sirolimus-eluting stents. After stent implantation in the tracheo-bronchial system of rabbits, we found tissue reactions comparable to those seen after stent implantation into the vascular system. There was no difference between coated and uncoated stents with regard to quality and quantity of tissue proliferation. We found, however, a significantly different inflammatory reaction with a more pronounced foreign-body reaction in sirolimus-coated stents. In our small series, drug-eluting stents did not exhibit any benefit over bare metal stents in an experimental setting.

  17. Cost effectiveness of drug-eluting stents as compared with bare metal stents in patients with coronary artery disease.

    PubMed

    Wisløff, Torbjørn; Atar, Dan; Sønbø Kristiansen, Ivar

    2013-01-01

    The aim of this study was to estimate the incremental cost effectiveness of replacing bare metal stents (BMS) by drug-eluting stents (DES) when using trial data and registry data. We developed a Markov model (model of cost effectiveness of coronary artery disease) in which 60-year-old patients started by undergoing percutaneous coronary intervention for acute or subacute coronary artery disease. The patients are followed until death or 100 years of age. Data on the occurrence of events (revascularization, acute myocardial infarction, and death) were based on Scandinavian registry data. Separate analyses were conducted with data on effectiveness based on randomized controlled trials and patient registries. On using trial data, it was found that sirolimus-eluting stents (SES) yield 0.003 greater life expectancy and $3300 lower costs than do BMS (dominant strategy). Paclitaxel-eluting stents (PES) yield 0.148 more life years than do SES at additional lifetime costs of $2800 ($21,400 per life year gained). On using registry data, the cost per life year gained was found to be $4900 when replacing BMS with DES. Probabilistic sensitivity analyses, on the other hand, indicate that PES only has a 50%-75% probability of being cost effective, regardless of the type of effectiveness data. DESs are cost effective with current willingness to pay for life year gains. Whether PES or SES is the most effective DES remains uncertain.

  18. Prevalence, Features, and Prognostic Importance of Edge Dissection After Drug-Eluting Stent Implantation: An ADAPT-DES Intravascular Ultrasound Substudy.

    PubMed

    Kobayashi, Nobuaki; Mintz, Gary S; Witzenbichler, Bernhard; Metzger, D Christopher; Rinaldi, Michael J; Duffy, Peter L; Weisz, Giora; Stuckey, Thomas D; Brodie, Bruce R; Parvataneni, Rupa; Kirtane, Ajay J; Stone, Gregg W; Maehara, Akiko

    2016-07-01

    Intravascular ultrasound detects stent edge dissections after percutaneous coronary intervention that are not seen angiographically. This study investigated the association between stent edge dissections and clinical outcomes. ADAPT-DES (Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents) was a large-scale, prospective, multicenter study of patients undergoing drug-eluting stent implantation. In this prospective substudy, 2062 patients (2433 lesions) were evaluated with intravascular ultrasound to characterize the morphological features and clinical outcomes of stent edge dissection after percutaneous coronary intervention. The prevalence of post-percutaneous coronary intervention stent edge dissection was 6.6% per lesion (161 of 2433). Calcified plaque at the proximal stent edge (relative risk [RR]=1.72; P=0.04) and proximal stent edge expansion (RR=1.18; P=0.004) were predictors for proximal dissection; attenuated plaque at the distal stent edge (RR=3.52; P=0.004), distal reference plaque burden (RR=1.56; P<0.0001), and distal edge stent expansion (RR=1.11; P=0.02) were predictors for distal dissection. At 1-year follow-up, target lesion revascularization was more common in lesions with versus without dissection (5.2% versus 2.7%; P=0.04). Multivariable analysis indicated that residual dissection was associated with target lesion revascularization at 1-year follow-up (RR=2.67; P=0.02). Among lesions with dissection, smaller effective lumen area increased the risk of target lesion revascularization at 1-year follow-up (cutoff value of 5.1 mm(2); P=0.05). Greater stent expansion and the presence of large, calcified, and/or attenuated plaques were independent predictors of stent edge dissection. Residual stent edge dissection, especially with a smaller effective lumen area, was associated with target lesion revascularization during 1-year follow-up after drug-eluting stent implantation. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00638794

  19. Bioresorbable polymer coated drug eluting stent: a model study.

    PubMed

    Rossi, Filippo; Casalini, Tommaso; Raffa, Edoardo; Masi, Maurizio; Perale, Giuseppe

    2012-07-02

    In drug eluting stent technologies, an increased demand for better control, higher reliability, and enhanced performances of drug delivery systems emerged in the last years and thus offered the opportunity to introduce model-based approaches aimed to overcome the remarkable limits of trial-and-error methods. In this context a mathematical model was studied, based on detailed conservation equations and taking into account the main physical-chemical mechanisms involved in polymeric coating degradation, drug release, and restenosis inhibition. It allowed highlighting the interdependence between factors affecting each of these phenomena and, in particular, the influence of stent design parameters on drug antirestenotic efficacy. Therefore, the here-proposed model is aimed to simulate the diffusional release, for both in vitro and the in vivo conditions: results were verified against various literature data, confirming the reliability of the parameter estimation procedure. The hierarchical structure of this model also allows easily modifying the set of equations describing restenosis evolution to enhance model reliability and taking advantage of the deep understanding of physiological mechanisms governing the different stages of smooth muscle cell growth and proliferation. In addition, thanks to its simplicity and to the very low system requirements and central processing unit (CPU) time, our model allows obtaining immediate views of system behavior.

  20. Stent thrombosis with bioabsorbable polymer drug-eluting stents: insights from the Food and Drug Administration database.

    PubMed

    Khan, Abdur R; Tripathi, Avnish; Farid, Talha A; Abaid, Bilal; Bhatt, Deepak L; Resar, Jon R; Flaherty, Michael P

    2017-11-01

    SYNERGY, a bioabsorbable polymer-based, everolimus-eluting stent (BP-DES), recently received regulatory approval in the USA for use in percutaneous coronary interventions. Yet, information on the safety of BP-DES in routine clinical practice is limited. Our aim was to compare the safety of the recently approved BP-DES with current durable polymer drug-eluting stents (DP-DES) by analyzing adverse events, namely, stent thrombosis (ST), reported to the Manufacturer and User Facility Device Experience (MAUDE) database. The MAUDE database requires nationwide mandatory notification for adverse events on devices approved for clinical use. This database was searched for adverse events reported between 1 October 2015 and 25 December 2016, encountered after the placement of either BP-DES or DP-DES. Only those adverse events were included where the exposure period to the stents was comparable after the index procedure. Of all the adverse events reported, the event of interest was ST. A total of 951 adverse events were reported. ST occurred in 48/951 of all events, 31/309 and 17/642 when BP-DES or DP-DES were used, respectively (P=0.00001). Of the 31 ST events with BP-DES, 68% (21/31) occurred within less than or equal to 24 h of the index procedure and 52% (16/31) occurred within less than or equal to 2 h. Our results raise the possibility of an increased risk of ST, particularly early ST (within 24 h), with the recently approved BP-DES. However, because of the inherent limitations of reporting within the MAUDE database, these data merely highlight a potential need for additional surveillance and randomized trials to assess further the safety of the bioabsorbable platform.

  1. Drug-eluting stent in malignant biliary obstruction

    NASA Astrophysics Data System (ADS)

    Lee, Dong-Ki; Jang, Sung Ill

    2012-10-01

    Endoscopic stent insertion is the treatment of choice for patients with malignant biliary obstruction. However, conventional stents enable only mechanical palliation of the obstruction, without any anti-tumor effects. Drugeluting stent (DES), which was first introduced in coronary artery disease, are currently under investigation for sustaining stent patency and prolonging patient survival by inhibiting tumor ingrowth in malignant biliary obstruction. Many factors affecting efficient drug delivery have been studied to determine how drugs with antitumor effects suppress tumor ingrowth, including the specific drugs incorporated, means of incorporating the drugs, mode of drug release, and stent structure. Advances have resulted in the construction of more effective non-vascular DES and ongoing clinical research. Non-vascular DES is expected to play a vital role in prolonging the survival of patients with malignant biliary obstruction.

  2. Biodegradable Polymer Biolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents in Patients With Coronary Artery Disease: Final 5-Year Report From the COMPARE II Trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent).

    PubMed

    Vlachojannis, Georgios J; Smits, Pieter C; Hofma, Sjoerd H; Togni, Mario; Vázquez, Nicolás; Valdés, Mariano; Voudris, Vassilis; Slagboom, Ton; Goy, Jean-Jaques; den Heijer, Peter; van der Ent, Martin

    2017-06-26

    This analysis investigates the 5-year outcomes of the biodegradable polymer biolimus-eluting stent (BP-BES) and durable polymer everolimus-eluting stent (DP-EES) in an all-comers population undergoing percutaneous coronary intervention. Recent 1- and 3-year results from randomized trials have indicated similar safety and efficacy outcomes of BP-BES and DP-EES. Whether benefits of the biodegradable polymer device arise over longer follow-up is unknown. Moreover, in-depth, prospective, long-term follow-up data on metallic drug-eluting stents with durable or biodegradable polymers are scarce. The COMPARE II trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent) was a prospective, randomized, multicenter, all-comers trial in which 2,707 patients were randomly allocated (2:1) to BP-BES or DP-EES. The pre-specified endpoint at 5 years was major adverse cardiac events, a composite of cardiac death, nonfatal myocardial infarction, or target vessel revascularization. Five-year follow-up was available in 2,657 patients (98%). At 5 years, major adverse cardiac events occurred in 310 patients (17.3%) in the BP-BES group and 142 patients (15.6%) in the DP-EES group (p = 0.26). The rate of the combined safety endpoint all-cause death or myocardial infarction was 15.0% in the BP-BES group versus 14.8% in the DP-EES group (p = 0.90), whereas the efficacy measure target vessel revascularization was 10.6% versus 9.0% (p = 0.18), respectively. Interestingly, definite stent thrombosis rates did not differ between groups (1.5% for BP-BES vs. 0.9% for DP-EES; p = 0.17). The 5-year analysis comparing biodegradable polymer-coated BES and the durable polymer-coated EES confirms the initial early- and mid-term results regarding similar safety and efficacy outcomes in this all-comers percutaneous coronary intervention population. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights

  3. New stent design for use in small coronary arteries during percutaneous coronary intervention

    PubMed Central

    Granada, Juan F; Huibregtse, Barbara A; Dawkins, Keith D

    2010-01-01

    Patients with diabetes mellitus, of female gender, increased age, and/or with peripheral vascular disease often develop coronary stenoses in small caliber vessels. This review describes treatment of these lesions with the paclitaxel-eluting 2.25 mm TAXUS® Liberté® Atom™ stent. Given the same stent composition, polymer, antirestenotic drug (paclitaxel), and release kinetics as the first-generation 2.25 mm TAXUS® Express® Atom™ stent, the second-generation TAXUS Liberté Atom stent incorporates improved stent design characteristics, including thinner struts (0.0038 versus 0.0052 inches), intended to increase conformability and deliverability. In a porcine noninjured coronary artery model, TAXUS Liberté Atom stent implantation in small vessels demonstrated complete strut tissue coverage compared with the bare metal stent control, suggesting a similar degree of tissue healing between the groups at 30, 90, and 180 days. The prospective, single-armed TAXUS ATLAS Small Vessel trial demonstrated improved instent late loss (0.28 ± 0.45 versus 0.84 ± 0.57 mm, P < 0.001), instent binary restenosis (13.0% versus 38.1%, P < 0.001), and target lesion revascularization (5.8% versus 17.6%, P < 0.001) at nine months with the TAXUS Liberté Atom stent as compared with the bare metal Express stent control, with similar safety measures between the two groups. The TAXUS Liberté Atom also significantly reduced nine-month angiographic rates of both instent late loss (0.28 ± 0.45 versus 0.44 ± 0.61 mm, P = 0.03) and instent binary restenosis (13.0% versus 25.9%, P = 0.02) when compared with the 2.25 mm TAXUS Express Atom control. The observed reduction in target lesion revascularization with the TAXUS Liberté Atom compared with the TAXUS Express Atom at nine months (5.8% versus 13.7%, P = 0.02) was sustained through three years (10.0% versus 22.1%, P = 0.008) with similar, stable safety outcomes between the groups. In conclusion, these data confirm the safety and favorable

  4. Cost effectiveness of drug eluting coronary artery stenting in a UK setting: cost-utility study.

    PubMed

    Bagust, A; Grayson, A D; Palmer, N D; Perry, R A; Walley, T

    2006-01-01

    To assess the cost effectiveness of drug eluting stents (DES) compared with conventional stents for treatment of symptomatic coronary artery disease in the UK. Cost-utility analysis of audit based patient subgroups by means of a simple economic model. Tertiary care. 12 month audit data for 2884 patients receiving percutaneous coronary intervention with stenting at the Cardiothoracic Centre Liverpool between January 2000 and December 2002. Risk of repeat revascularisation within 12 months of index procedure and reduction in risk from use of DES. Economic modelling was used to estimate the cost-utility ratio and threshold price premium. Four factors were identified for patients undergoing elective surgery (n = 1951) and two for non-elective surgery (n = 933) to predict risk of repeat revascularisation within 12 months. Most patients fell within the subgroup with lowest risk (57% of the elective surgery group with 5.6% risk and 91% of the non-elective surgery group with 9.9% risk). Modelled cost-utility ratios were acceptable for only one group of high risk patients undergoing non-elective surgery (only one patient in audit data). Restricting the number of DES for each patient improved results marginally: 4% of stents could then be drug eluting on economic grounds. The threshold price premium justifying 90% substitution of conventional stents was estimated to be 112 pound sterling (212 USD, 162 pound sterling) (sirolimus stents) or 89 pound sterling (167 USD, 130 pound sterling) (paclitaxel stents). At current UK prices, DES are not cost effective compared with conventional stents except for a small minority of patients. Although the technology is clearly effective, general substitution is not justified unless the price premium falls substantially.

  5. Endothelialization of sirolimus-eluting stents with slow and extended drug release in the porcine overstretch model.

    PubMed

    Frey, Daniela; Billinger, Michael; Meier, Pascal; Beslac, Olgica; Grossenbacher, Raphael; Hänni, Beat; Hess, Otto M

    2008-12-01

    Vascular healing of intracoronary stents has been shown to be delayed in drug-eluting stents (DES) due to the cytotoxic compounds on the stent surface that prevent stent ingrowth and endothelialization. The lack of endothelialization explains the occurrence of late and very late stent thrombosis in DES. In 11 house swines (body weight 38-45 kg), 3 stents were implanted randomly into the 3 large epicardial coronary arteries, namely a bare-metal stent (BMS), a sirolimus-eluting stent with slow-release (SES) and a SES with extended-release (SESXR). Stent length was 18 mm, and stent diameter 3 mm. All stents were of identical design. Animals were followed for 3 (n = 3), 7 (n = 4) and 14 (n = 4) days, respectively. One animal died before implantation due to hyperthermia. On the day of explantation, the animals were euthanized and endothelialization was tested by scanning electron microscopy after drying and sputtering the samples. Endothelial coverage was determined semiquantitatively by 2 observers. Endothelialization was more rapid with BMS and SESXR than SES at 3 and 14 days. At 7 days there were no significant differences between the 2 SES. Endothelialization of intracoronary stents is faster with BMS and SESXR at 3 days than with SES. These differences persist at 14 days, suggesting delayed vascular healing with the slow-release SES.

  6. Quantitative spatial distribution of sirolimus and polymers in drug-eluting stents using confocal Raman microscopy.

    PubMed

    Balss, K M; Llanos, G; Papandreou, G; Maryanoff, C A

    2008-04-01

    Raman spectroscopy was used to differentiate each component found in the CYPHER Sirolimus-eluting Coronary Stent. The unique spectral features identified for each component were then used to develop three separate calibration curves to describe the solid phase distribution found on drug-polymer coated stents. The calibration curves were obtained by analyzing confocal Raman spectral depth profiles from a set of 16 unique formulations of drug-polymer coatings sprayed onto stents and planar substrates. The sirolimus model was linear from 0 to 100 wt % of drug. The individual polymer calibration curves for poly(ethylene-co-vinyl acetate) [PEVA] and poly(n-butyl methacrylate) [PBMA] were also linear from 0 to 100 wt %. The calibration curves were tested on three independent drug-polymer coated stents. The sirolimus calibration predicted the drug content within 1 wt % of the laboratory assay value. The polymer calibrations predicted the content within 7 wt % of the formulation solution content. Attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectra from five formulations confirmed a linear response to changes in sirolimus and polymer content. Copyright 2007 Wiley Periodicals, Inc.

  7. 2-year results of the AUTAX (Austrian Multivessel TAXUS-Stent) registry beyond the SYNTAX (synergy between percutaneous coronary intervention with TAXUS and cardiac surgery) study.

    PubMed

    Gyöngyösi, Mariann; Christ, Günter; Lang, Irene; Kreiner, Gerhard; Sochor, Heinz; Probst, Peter; Neunteufl, Thomas; Badr-Eslam, Rosa; Winkler, Susanne; Nyolczas, Noemi; Posa, Aniko; Leisch, Franz; Karnik, Ronald; Siostrzonek, Peter; Harb, Stefan; Heigert, Matthias; Zenker, Gerald; Benzer, Werner; Bonner, Gerhard; Kaider, Alexandra; Glogar, Dietmar

    2009-08-01

    The multicenter AUTAX (Austrian Multivessel TAXUS-Stent) registry investigated the 2-year clinical/angiographic outcomes of patients with multivessel coronary artery disease after implantation of TAXUS Express stents (Boston Scientific, Natick, Massachusetts), in a "real-world" setting. The AUTAX registry included patients with 2- or 3-vessel disease, with/without previous percutaneous coronary intervention (PCI) and concomitant surgery. Patients (n = 441, 64 +/- 12 years, 78% men) (n = 1,080 lesions) with possible complete revascularization by PCI were prospectively included. Median clinical follow-up was 753 (quartiles 728 to 775) days after PCI in 95.7%, with control angiography of 78% at 6 months. The primary end point was the composite of major adverse cardiac (nonfatal acute myocardial infarction [AMI], all-cause mortality, target lesion revascularization [TLR]) and cerebrovascular events (MACCE). Potential risk factor effects on 2-year MACCE were evaluated using Cox regression. Complete revascularization was successful in 90.5%, with left main PCI of 6.8%. Rates of acute, subacute, and late stent thrombosis were 0.7%, 0.5%, and 0.5%. Two-year follow-up identified AMI (1.4%), death (3.6%), stroke (0.2%), and TLR (13.1%), for a composite MACCE of 18.3%. The binary restenosis rate was 10.8%. The median of cumulative SYNTAX score was 23.0 (range 12.0 to 56.5). The SYNTAX score did not predict TLR or MACCE, due to lack of scoring of restenotic or bypass stenoses (29.8%). Age (hazard ratio [HR]: 1.03, p = 0.019) and acute coronary syndrome (HR: 2.1, p = 0.001) were significant predictors of 2-year MACCE. Incomplete revascularization predicted death or AMI (HR: 3.84, p = 0.002). With the aim of complete revascularization, TAXUS stent implantations can be safe for patients with multivessel disease. The AUTAX registry including patients with post-PCI lesions provides additional information to the SYNTAX (Synergy Between Percutaneous Coronary Intervention With TAXUS

  8. Metallic Limus-Eluting Stents Abluminally Coated with Biodegradable Polymers: Angiographic and Clinical Comparison of a Novel Ultra-Thin Sirolimus Stent Versus Biolimus Stent in the DESTINY Randomized Trial.

    PubMed

    Lemos, Pedro A; Abizaid, Alexandre A C; Meireles, George C; Sarmento-Leite, Rogério; Prudente, Mauricio; Cantarelli, Marcelo; Dourado, Adriano D; Mariani, Jose; Perin, Marco A; Costantini, Costantino; Costa, Ricardo A; Costa, José Ribamar; Chamie, Daniel; Campos, Carlos A; Ribeiro, Expedito

    2015-12-01

    To evaluate the outcomes of patients treated with a new drug-eluting stent formulation with low doses of sirolimus, built in an ultra-thin-strut platform coated with biodegradable abluminal coating. This study is a randomized trial that tested the main hypothesis that the angiographic late lumen loss of the novel sirolimus-eluting stent is noninferior compared with commercially available biolimus-eluting stent. A final study population comprising 170 patients with one or two de novo lesions was randomized in the ratio 2:1 for sirolimus-eluting stent or biolimus-eluting stent, respectively. The primary endpoint was 9-month angiographic in-stent late lumen loss. Adverse clinical events were prospectively collected for 1 year. After 9 months, the novel sirolimus-eluting stent was shown noninferior compared with the biolimus stent for the primary endpoint (angiographic in-stent late lumen loss: 0.20 ± 0.29 mm vs. 0.15 ± 0.20 mm, respectively; P value for noninferiority <0.001). The 1-year incidence of death, myocardial infarction, repeat revascularization, and stent thrombosis remained low and not significantly different between the groups. The present randomized trial demonstrates that the tested novel sirolimus-eluting stent was angiographically noninferior in comparison with a last-generation biolimus-eluting stent. © 2015 John Wiley & Sons Ltd.

  9. Evaluation of a bifurcation drug-eluting stent system versus provisional T-stenting in a perfused synthetic coronary artery model.

    PubMed

    Rizik, David G; Klag, Joseph M; Tenaglia, Alan; Hatten, Thomas R; Barnhart, Marianne; Warnack, Boris

    2009-12-01

    Provisional T-stenting is a widely used strategy for the treatment of coronary artery bifurcation lesions. However, the use of conventional stents in this setting is limited by multiple factors; this includes technical considerations such as wire wrap when accessing the involved vessel, and stent overlap at or near the carina of the lesion. In addition, current slotted tube stent technology tends to be associated with gaps in the coverage of the side branch ostium, which may result in restenosis in that segment of the lesion. The Pathfinder device, now more commonly referred to as the Xience Side Branch Access System (Xience SBA) is a drug-eluting stent (DES) designed specifically to assist in the treatment of bifurcation lesions by allowing wire access into the side branch, irrespective of the treatment strategy to be employed. The Xience SBA drug-eluting stent was compared with the standard Vision coronary stent system using a provisional T-stenting strategy in a perfused synthetic model of the coronary vasculature with side branch angulations of 30 degrees , 50 degrees , 70 degrees , and 90 degrees . Stent delivery was performed under fluoroscopic guidance. Following the procedure, high-resolution 2D Faxitron imaging was used to evaluate deployment accuracy of the side branch stent relative to the main branch stent. Deployment of the Xience SBA was accomplished in the same total time as the standard stents in a provisional T-stenting approach (14.9 vs. 14.6 minutes). However, the time required to achieve stent deployment in the main branch was less with the Xience SBA (4.0 vs. 6.6 minutes), and as a result, total contrast usage (49.4 vs. 69.4 cm(3)) and fluoroscopy time (5.1 vs. 6.2 minutes) was lower. Additionally, the Xience SBA had a lower incidence of wire wrap (22% vs. 89%) and less distal protrusion of the side branch stent into the main branch (0.54 vs. 1.21 mm). Significant gaps in ostial side branch coverage were not seen in either group. The Xience

  10. Application of underdamped Langevin dynamics simulations for the study of diffusion from a drug-eluting stent

    NASA Astrophysics Data System (ADS)

    Regev, Shaked; Farago, Oded

    2018-10-01

    We use a one-dimensional two layer model with a semi-permeable membrane to study the diffusion of a therapeutic drug delivered from a drug-eluting stent (DES). The rate of drug transfer from the stent coating to the arterial wall is calculated by using underdamped Langevin dynamics simulations. Our results reveal that the membrane has virtually no delay effect on the rate of delivery from the DES. The work demonstrates the great potential of underdamped Langevin dynamics simulations as an easy to implement, efficient, method for solving complicated diffusion problems in systems with a spatially-dependent diffusion coefficient.

  11. In-stent neoatherosclerosis and tissue characteristics of restenotic lesions following implantation of second generation drug-eluting stents in unrestricted coronary lesions: Optical frequency domain imaging study.

    PubMed

    Sabbah, Mahmoud; Kadota, Kazushige; El-Eraky, Azza; Kamal, Hanan M; Abdellah, Ahmed-Tageldien; El Hawary, Ahmed

    2017-06-01

    Differences in stent platform, polymer coatings, and antirestenotic drugs among the current in use second-generation drug-eluting stents (G2-DESs) may induce significant variations in neointimal response and vascular healing, which may impact the prevalence of neoatherosclerosis (NA) and morphological appearance of the restenotic tissue. Utilizing Optical frequency domain imaging, two independent reviewers, retrospectively compared the prevalence of neoatherosclerosis (NA), and the morphological differences, and tissue characteristics of 50 G2-DESs in-stent restenosis (ISR) lesions (35 everolimus-eluting stent [22 cobalt-chromium (CoCr), 13 platinum-chromium (PtCr)], and 15 biolimus-eluting stent [BES]) implanted liberally in unrestricted coronary lesions. More than half of the stents were implanted in type C lesions, while 40% of the stents were implanted primarily in lesions with recanalized chronic total occlusion. NA, defined as a neointima formation with the presence of lipids or calcification, was observed in fewer than half (24/50) of all ISR lesions with no significant in-between group differences (41%, 69%, and 40% in CoCr, PtCr, and BES respectively, P = 0.22), nor were there any significant differences in the morphological appearance or tissue characteristics between all G2-DESs subtypes. Acknowledging some limitations, our results may suggest that the prevalence of NA and the morphological appearance of restenotic lesions might not differ when G2-DESs are implanted in unrestricted, rather complex, coronary lesions. © 2017, Wiley Periodicals, Inc.

  12. In vitro hemocompatibility and cytocompatibility of dexamethasone-eluting PLGA stent coatings

    NASA Astrophysics Data System (ADS)

    Zhang, Jiang; Liu, Yang; Luo, Rifang; Chen, Si; Li, Xin; Yuan, Shuheng; Wang, Jin; Huang, Nan

    2015-02-01

    Drug-eluting stents (DESs) have been an important breakthrough for interventional cardiology applications since 2002. Though successful in reducing restenosis, some adverse clinical problems still emerged, which were mostly caused by the bare-metal stents and non-biodegradable polymer coatings, associated with the delayed endothelialization process. In this study, dexamethasone-loaded poly (lactic-co-glycolic acid) (PLGA) coatings were developed to explore the potential application of dexamethasone-eluting stents. Dexamethasone-eluting PLGA stents were prepared using ultrasonic atomization spray method. For other tests like stability and cytocompatibility and hemocompatibility tests, dexamethasone loaded coatings were deposited on 316L SS wafers. Fourier transform-infrared spectroscopy (FT-IR) results demonstrated that there was no chemical reaction between PLGA and dexamethasone. The balloon expansion experiment and surface morphology observation suggested that the stent coatings were smooth and uniform, and could also withstand the compressive and tensile strains imparted without cracking after stent expansion. The drug release behavior in vitro indicated that dexamethasone existed burst release within 1 day, but it presented linear release characteristics after 6 days. In vitro platelets adhesion, activation test and APTT test were also done, which showed that after blending dexamethasone into PLGA, the hemocompatibility was improved. Besides, dexamethasone and dexamethasone-loaded PLGA coatings could significantly inhibit the attachment and proliferation of smooth muscle cells.

  13. Enhanced performance of magnesium alloy for drug-eluting vascular scaffold application

    NASA Astrophysics Data System (ADS)

    Dong, Hongzhou; Li, Daikun; Mao, Daoyong; Bai, Ningning; Chen, Yashi; Li, Qing

    2018-03-01

    Bio-absorbable magnesium alloys drug-eluting vascular scaffold was developed to resolve the defect of permanent metal and drug-eluting stents, most notably a chronic vessel wall inflammation and the risk of stent thrombosis. Nevertheless, violent chemical reaction and rapid degradation under physiological conditions limits their application. Furthermore, multifunctional drug-eluting stents which could reduce the formation of thrombus and repair the damaged vessels need more attention to fundamentally cure the coronary artery disease. Herein, a drug delivery system (Mg/MgO/PLA-FA) which can realize sustainable release of ferulaic acid was designed via anodic oxidation process and dip coating process. Electrochemical tests and immersion experiments showed that the superior anticorrosion behavior, it is due to the dense MgO-PLA composite layer. The released ferulaic acid can effectively decrease platelets adhesion and aggregation during the early stage of implantation. Besides, hemolysis tests showed that the composite coatings endowed the Mg alloy with a low hemolysis ratio. The Mg/MgO/PLA-FA composite materials may be appropriate for applications on biodegradable Mg alloys drug-eluting stents.

  14. Paclitaxel-eluting versus sirolimus-eluting stents in diabetes mellitus: a report from the National Heart, Lung, and Blood Institute Dynamic Registry.

    PubMed

    Wolf, William M; Vlachos, Helen A; Marroquin, Oscar C; Lee, Joon S; Smith, Conrad; Anderson, William D; Schindler, John T; Holper, Elizabeth M; Abbott, J Dawn; Williams, David O; Laskey, Warren K; Kip, Kevin E; Kelsey, Sheryl F; Mulukutla, Suresh R

    2010-02-01

    Diabetes is a powerful predictor of adverse events in patients undergoing percutaneous coronary intervention. Drug-eluting stents reduce restenosis rates compared with bare metal stents; however, controversy remains regarding which drug-eluting stents provides greater benefit in patients with diabetes. Accordingly, we compared the safety and efficacy of sirolimus-eluting stents (SES) with paclitaxel-eluting stents (PES) among diabetic patients in a contemporary registry. Using the National Heart, Lung, and Blood Institute Dynamic Registry, we evaluated 2-year outcomes of diabetic patients undergoing percutaneous coronary interventions with SES (n=677) and PES (n=328). Clinical and demographic characteristics, including age, body mass index, insulin use, left ventricular function, and aspirin/clopidogrel use postprocedure, did not differ significantly between the groups except that PES-treated patients had a greater frequency of hypertension and hyperlipidemia. At the 2-year follow-up, no significant differences were observed between PES and SES with regard to safety or efficacy end points. PES- and SES-treated patients had similar rates of death (10.7% versus 8.2%, P=0.20), death and myocardial infarction (14.9% versus 13.6%, P=0.55), repeat revascularization (14.8% versus 17.8%, P=0.36), and stent thrombosis (1.3% versus 1.3%, P=0.95). After adjustment, no significant differences between the 2 stent types in any outcome were observed. PES and SES are equally efficacious and have similar safety profiles in diabetic patients undergoing percutaneous coronary interventions in clinical practice.

  15. Use of drug-eluting stents in Victorian public hospitals.

    PubMed

    Yan, Bryan P; Ajani, Andrew E; Duffy, Stephen J; New, Gishel; Horrigan, Mark; Szto, Gregory; Walton, Antony; Eccleston, David; Lefkovits, Jeffery; Black, Alexander; Sebastian, Martin; Brennan, Angela L; Reid, Christopher M; Clark, David J

    2006-10-02

    We aimed to assess the pattern of use of drug-eluting stents (DESs) in patients undergoing percutaneous coronary interventions (PCIs) in Victorian public hospitals. Prospective study comparing the use of one or more DESs versus bare-metal stents (BMSs) only, in consecutive patients undergoing 2428 PCIs with stent implantation from 1 April 2004 to 31 December 2005 at seven Victorian public hospitals. Adherence to current Victorian Department of Human Services guidelines which recommend DES use in patients with high-risk features for restenosis (diabetes, small vessels, long lesions, in-stent restenotic lesions, chronic total occlusions and bifurcation lesions). Of the 2428 PCIs performed, at least one DES was implanted in 1101 (45.3%) and BMSs only were implanted in 1327 (54.7%). In 87.7% (966/1101) of PCI with DESs, there was at least one criterion for high risk of restenosis. DESs were more likely to be used in patients with diabetes (risk ratio [RR], 2.45; 95% CI, 2.02-2.97), small vessels (RR, 3.35; 95%CI, 2.35-4.76), long lesions (RR, 3.87; 95% CI, 3.23-4.65), in-stent restenotic lesions (RR, 3.98; 95%CI, 2.67-6.06), chronic total occlusions (RR, 1.30; 95% CI, 0.51-2.88) and bifurcation lesions (RR, 2.23; 95%CI, 1.57-3.17). However, 66.2% (1608/2428) of all PCIs were in patients eligible for DESs according to Victorian guidelines, and in 39.9% (642/1608) of these PCIs, a BMS was used. In Victorian public hospitals, DESs have been largely reserved for patients at high risk of restenosis in accordance with Department of Human Services guidelines. However, many patients with high-risk criteria for restenosis did not receive DESs. Greater use of DESs in these patients may improve outcomes by reducing the need for repeat revascularisation.

  16. Impact of stent length on clinical outcomes of first-generation and new-generation drug-eluting stents.

    PubMed

    Konishi, Hirokazu; Miyauchi, Katsumi; Dohi, Tomotaka; Tsuboi, Shuta; Ogita, Manabu; Naito, Ryo; Kasai, Takatoshi; Tamura, Hiroshi; Okazaki, Shinya; Isoda, Kikuo; Daida, Hiroyuki

    2016-04-01

    The aim of this study is to compare first- and new-generation drug-eluting stents (DESs) which are implanted in long lesion. Stent length is known to be a predictor of adverse events after percutaneous coronary intervention (PCI), even with the first-generation DESs. The introduction of new-generation DESs has reduced the rates of adverse clinical events. However, the impact of stent length on long-term clinical outcomes is not well known. A total of 1181 consecutive patients who underwent PCI using either a first-generation DES (n = 885) or a new-generation DES (n = 296) between 2004 and 2011 were investigated. In each of the stent groups, the patients were divided into two groups by stent length (>32 and ≤32 mm) and compared. During the follow-up period, the incidence of major adverse cardiac events (MACEs) was significantly higher for patients with long stents implanted than with short stents (P < 0.01; log-rank test) in the first-generation DES group. However, there was no difference in the incidence of MACEs between the long- and short-stent groups in the new-generation DES group (P = 0.24; log-rank test). On multivariate Cox regression analysis, stent length was not associated with adverse events in the new-generation DES groups [hazard ratio (HR) 0.87; 95 % confidence interval (95 % CI) 0.71-1.04; P = 0.14]. Implanted stent length was significantly associated with a higher risk of MACEs in patients who received first-generation DESs, but not in patients who received the new-generation DESs.

  17. Comparison of early-phase arterial repair following cobalt-chrome everolimus-eluting stent and slow-release zotarolimus-eluting stent: an angioscopic study.

    PubMed

    Ishihara, Takayuki; Iida, Osamu; Fujita, Masashi; Masuda, Masaharu; Okamoto, Shin; Nanto, Kiyonori; Kanda, Takashi; Tsujimura, Takuya; Sunaga, Akihiro; Awata, Masaki; Nanto, Shinsuke; Uematsu, Masaaki

    2018-04-01

    Whether arterial repair following implantation of drug-eluting stents (DES) of the second generation differs among stent types remains unknown. We examined 41 DES placed in 28 patients (age 72 ± 7 years, male 89%) presenting with stable angina pectoris due to de novo lesions in native coronary arteries. Coronary angioscopy was performed 4 ± 1 months after stent implantation. Patients were divided into two groups based on the DES types: 22 cobalt-chrome everolimus-eluting stents (CoCr-EES) in 13 patients and 19 slow-release zotarolimus-eluting stents (R-ZES) in 15 patients. Neointimal coverage (NIC) was graded as: grade 0, stent struts exposed; grade 1, struts bulging into the lumen, although covered; grade 2, struts embedded in the neointima, but translucent; grade 3, struts fully embedded and invisible. NIC was defined as heterogeneous when the NIC grade variation was ≥1. Presence of thrombus was also investigated. Distribution of dominant NIC grade (CoCr-EES: grade 0, 9%; grade 1, 77%; grade 2, 9%; grade 3, 5%; R-ZES: grade 0, 16%; grade 1: 47%; grade 2, 37%; grade 3, 0%, P = 0.38) and heterogeneity of NIC (P = 0.43) were similar between CoCr-EES and R-ZES groups. Existence of thrombus was not significantly different in CoCr-EES and R-ZES (18 versus 42%, P = 0.17). Arterial repair occurred without significant differences between CoCr-EES and R-ZES 4 months after implantation.

  18. Stent-induced coronary artery stenosis characterized by multimodal nonlinear optical microscopy

    NASA Astrophysics Data System (ADS)

    Wang, Han-Wei; Simianu, Vlad; Locker, Mattew J.; Cheng, Ji-Xin; Sturek, Michael

    2011-02-01

    We demonstrate for the first time the applicability of multimodal nonlinear optical (NLO) microscopy to the interrogation of stented coronary arteries under different diet and stent deployment conditions. Bare metal stents and Taxus drug-eluting stents (DES) were placed in coronary arteries of Ossabaw pigs of control and atherogenic diet groups. Multimodal NLO imaging was performed to inspect changes in arterial structures and compositions after stenting. Sum frequency generation, one of the multimodalities, was used for the quantitative analysis of collagen content in the peristent and in-stent artery segments of both pig groups. Atherogenic diet increased lipid and collagen in peristent segments. In-stent segments showed decreased collagen expression in neointima compared to media. Deployment of DES in atheromatous arteries inhibited collagen expression in the arterial media.

  19. Numerical simulation on the effects of drug eluting stents at different Reynolds numbers on hemodynamic and drug concentration distribution.

    PubMed

    Chen, Yu; Xiong, Yan; Jiang, Wentao; Yan, Fei; Guo, Meng; Wang, Qingyuan; Fan, Yubo

    2015-01-01

    The changes of hemodynamics and drug concentration distribution caused by the implantation of drug eluting stents (DESs) in curved vessels have significant effects on In-Stent Restenosis. A 3D virtual stent with 90° curvature was modelled and the distribution of wall shear stress (WSS) and drug concentration in this model were numerically studied at Reynolds numbers of 200, 400, 600, 800. The results showed that (1) the intensity of secondary flow at the 45° cross-section was stronger than that at the 90° cross-section; (2) As the Reynolds number increases, the WSS decreases. When the Reynolds number reaches 600, the low-WSS region only accounts for 3% of the total area. (3) The effects of Reynolds number on drug concentration in the vascular wall decreases in proportionally and then the blood velocity increased 4 times, the drug concentration in the vascular wall decreased by about 30%. (4) The size of the high drug concentration region is inversely proportional to the Reynolds number. As the blood velocity increases, the drug concentration in the DES decreases, especially at the outer bend. It is beneficial for the patient to decrease vigorous activities and keep calm at the beginning of the stent implantation, because a substantial amount of the drug is released in the first two months of stent implantation, thus a calm status is conducive to drug release and absorption; Subsequently, appropriate exercise which increases the blood velocity is helpful in decreasing regions of low-WSS.

  20. Clinical Outcomes of Drug-Coated Balloons in Coronary Artery Disease Unsuitable for Drug-Eluting Stent Implantation.

    PubMed

    Iijima, Raisuke; Kougame, Norihiro; Hara, Hidehiko; Moroi, Masao; Nakamura, Masato

    2018-06-12

    The aim of this study was to investigate whether drug-coated balloon (DCB) treatment is effective for de novo coronary lesions that are unsuitable for drug-eluting stent (DES) implantation.Methods and Results:This retrospective study included 118 de novo lesions that were not suitable for DES implantation. Of the lesions, 40% was treated because of very small vessel disease. Patients with planned non-cardiac surgery and at high bleeding risk were 3% and 19%, respectively, and lesions that easily develop stent fracture comprised 26%. Clinically driven target lesion revascularization (TLR) was the primary endpoint. The rate of suboptimal lesion preparation before DCB treatment was set as the secondary endpoint. Optimal lesion preparation was defined as acquisition of Thrombolysis in Myocardial Infarction flow grade 3, minor coronary dissection, and residual stenosis ≤30%. The rate of suboptimal lesion preparation was 2.5% and 3 patients needed bail-out stenting. Accordingly, 115 patients were treated with a DCB. Clinically driven TLR had occurred in 8 patients (7.0%) at the 8-month follow-up. The presence of chronic total occlusion was identified as an independent predictor for TLR (odds 11.57; 95% confidence interval, 1.38-135.54; P=0.02). For lesions that are unsuitable for stent implantation, stent-less intervention using a DCB should be considered initially. The present study also highlighted that lesion preparation is key to a successful DCB strategy.

  1. Very late stent thrombosis and late target lesion revascularization after sirolimus-eluting stent implantation: five-year outcome of the j-Cypher Registry.

    PubMed

    Kimura, Takeshi; Morimoto, Takeshi; Nakagawa, Yoshihisa; Kawai, Kazuya; Miyazaki, Shunichi; Muramatsu, Toshiya; Shiode, Nobuo; Namura, Masanobu; Sone, Takahito; Oshima, Shigeru; Nishikawa, Hideo; Hiasa, Yoshikazu; Hayashi, Yasuhiko; Nobuyoshi, Masakiyo; Mitudo, Kazuaki

    2012-01-31

    There is a scarcity of long-term data from large-scale drug-eluting stent registries with a large enough sample to evaluate low-frequency events such as stent thrombosis (ST). Five-year outcomes were evaluated in 12 812 consecutive patients undergoing sirolimus-eluting stent (SES) implantation in the j-Cypher registry. Cumulative incidence of definite ST was low (30 day, 0.3%; 1 year, 0.6%; and 5 years, 1.6%). However, late and very late ST continued to occur without attenuation up to 5 years after sirolimus-eluting stent implantation (0.26%/y). Cumulative incidence of target lesion revascularization within the first year was low (7.3%). However, late target lesion revascularization beyond 1 year also continued to occur without attenuation up to 5 years (2.2%/y). Independent risk factors of ST were completely different according to the timing of ST onset, suggesting the presence of different pathophysiological mechanisms of ST according to the timing of ST onset: acute coronary syndrome and target of proximal left anterior descending coronary artery for early ST; side-branch stenting, diabetes mellitus, and end-stage renal disease with or without hemodialysis for late ST; and current smoking and total stent length >28 mm for very late ST. Independent risk factors of late target lesion revascularization beyond 1 year were generally similar to those risk factors identified for early target lesion revascularization. Late adverse events such as very late ST and late target lesion revascularization are continuous hazards, lasting at least up to 5 years after implantation of the first-generation drug-eluting stents (sirolimus-eluting stents), which should be the targets for developing improved coronary stents.

  2. Multivariate analysis applied to the study of spatial distributions found in drug-eluting stent coatings by confocal Raman microscopy.

    PubMed

    Balss, Karin M; Long, Frederick H; Veselov, Vladimir; Orana, Argjenta; Akerman-Revis, Eugena; Papandreou, George; Maryanoff, Cynthia A

    2008-07-01

    Multivariate data analysis was applied to confocal Raman measurements on stents coated with the polymers and drug used in the CYPHER Sirolimus-eluting Coronary Stents. Partial least-squares (PLS) regression was used to establish three independent calibration curves for the coating constituents: sirolimus, poly(n-butyl methacrylate) [PBMA], and poly(ethylene-co-vinyl acetate) [PEVA]. The PLS calibrations were based on average spectra generated from each spatial location profiled. The PLS models were tested on six unknown stent samples to assess accuracy and precision. The wt % difference between PLS predictions and laboratory assay values for sirolimus was less than 1 wt % for the composite of the six unknowns, while the polymer models were estimated to be less than 0.5 wt % difference for the combined samples. The linearity and specificity of the three PLS models were also demonstrated with the three PLS models. In contrast to earlier univariate models, the PLS models achieved mass balance with better accuracy. This analysis was extended to evaluate the spatial distribution of the three constituents. Quantitative bitmap images of drug-eluting stent coatings are presented for the first time to assess the local distribution of components.

  3. Characterization of drug-eluting stent (DES) materials with cluster secondary ion mass spectrometry (SIMS)

    NASA Astrophysics Data System (ADS)

    Mahoney, Christine M.; Patwardhan, Dinesh V.; Ken McDermott, M.

    2006-07-01

    Secondary ion mass spectrometry (SIMS) employing an SF 5+ polyatomic primary ion source was utilized to analyze several materials commonly used in drug-eluting stents (DES). Poly(ethylene- co-vinyl acetate) (PEVA), poly(lactic- co-glycolic acid) (PLGA) and various poly(urethanes) were successfully depth profiled using SF 5+ bombardment. The resultant molecular depth profiles obtained from these polymeric films showed very little degradation in molecular signal as a function of increasing SF 5+ primary ion dose when experiments were performed at low temperatures (signal was maintained for doses up to ˜5 × 10 15 ions/cm 2). Temperature was determined to be an important parameter in both the success of the depth profiles and the mass spectral analysis of the polymers. In addition to the pristine polymer films, paclitaxel (drug released in Taxus™ stent) containing PLGA films were also characterized, where it was confirmed that both drug and polymer signals could be monitored as a function of depth at lower paclitaxel concentrations (10 wt%).

  4. The efficacy and safety of drug-eluting balloons for the treatment of in-stent restenosis as compared with drug-eluting stents and with conventional balloon angioplasty

    PubMed Central

    Oh, Pyung Chun; Suh, Soon Yong; Kang, Woong Chol; Lee, Kyounghoon; Han, Seung Hwan; Ahn, Taehoon; Shin, Eak Kyun

    2016-01-01

    Background/Aims: Treatment of coronary in-stent restenosis (ISR) is still associated with a high incidence of recurrence. We aimed to compare the efficacy and safety of drug-eluting balloons (DEB) for the treatment of ISR as compared with conventional balloon angioplasty (BA) and drug-eluting stents (DES). Methods: Between January 2006 and May 2012 a total of 177 patients (188 lesions, 64.1 ± 11.7 years old) who underwent percutaneous coronary intervention for ISR were retrospectively enrolled. Clinical outcomes were compared between patients treated with DEB (n = 58, 32.8%), conventional BA (n = 65, 36.7%), or DES (n = 54, 30.5%). The primary end point was a major adverse cardiac event (MACE), defined as a composite of cardiac death, myocardial infarction, and target lesion revascularization(TLR). Results: Baseline characteristics were not different except for a history of previous MI, which was more frequent in patients treated by conventional BA or DES than in patients treated by DEB (40.0% vs. 48.1% vs. 17.2%, respectively, p = 0.002). The total incidences of MACEs were 10.7%, 7.4%, and 15.4% in patients treated by DEB, DES, or conventional BA, respectively (p > 0.05). TLR was more frequent in patients treated by conventional BA than in patients treated by DEB or DES, but this was not statistically significant (10.8% vs. 6.9% vs. 3.7%, p > 0.05 between all group pairs, respectively). Conclusions: This study showed that percutaneous coronary intervention using DEB might be a feasible alternative to conventional BA or DES implantation for treatment of coronary ISR. Further large-scaled, randomized study assessing long-term clinical and angiographic outcomes will be needed. PMID:26951915

  5. A no-reflow prediction model in patients with ST-elevation acute myocardial infarction and primary drug-eluting stenting.

    PubMed

    Wang, Chang-Hua; Chen, Yun-Dai; Yang, Xin-Chun; Wang, Le-Feng; Wang, Hong-Shi; Sun, Zhi-Jun; Liu, Hong-Bin

    2011-04-01

    This study was undertaken to assess independent no-reflow predictors in patients with ST-elevation acute myocardial infarction (STEMI) and primary drug-eluting stenting in the current interventional strategies. One thousand four hundred and thirteen patients with STEMI were successfully treated with primary drug-eluting stenting within 12 h after AMI. All clinical, angiographic and procedural data were collected. Univariate and multivariate logistic regression was used to identify independent no-reflow predictors. The no-reflow was found in 297 (21%) of 1413 patients. Univariate and multivariate logistic regression identified that age (>65 years, OR 1.47, 95% CI 1.46-1.49; p = 0.007), long time-to-reperfusion (>6 h, OR 1.27, 95% CI 1.16-1.40; p = 0.001), admission plasma glucose (>13.0 mmol/L, OR 1.27, 95% CI 1.16-1.40; p = 0.027), collateral circulation (0-1, OR 1.69, 95% CI 1.25-2.29; p = 0.001), pre-PCI thrombus score (≥4, OR 1.36, 95% CI 1.16-1.79; p = 0.011), and IABP use before PCI (OR 2.89, 95% CI 1.65-5.05; p < 0.0001) were independent no-reflow predictors. The no-reflow rate significantly increased as the number of independent predictors increased (0%, 6%, 15%, 25%, 40%, 50% and 100% in patients with 0, 1, 2, 3, 4, 5, and 6 independent predictors, respectively; p < 0.0001). The prediction model consisted of six no-reflow predictors in patients with STEMI and primary drug-eluting stenting and should be confirmed in large-scale prospective studies.

  6. Direct implantation of rapamycin-eluting stents with bioresorbable drug carrier technology utilising the Svelte coronary stent-on-a-wire: the DIRECT II study.

    PubMed

    Verheye, Stefan; Khattab, Ahmed A; Carrie, Didier; Stella, Pieter; Slagboom, Ton; Bartunek, Jozef; Onuma, Yoshinobu; Serruys, Patrick W

    2016-08-05

    Our aim was to demonstrate the safety and efficacy of the Svelte sirolimus-eluting coronary stent-on-a-wire Integrated Delivery System (IDS) with bioresorbable drug coating compared to the Resolute Integrity zotarolimus-eluting stent with durable polymer in patients with de novo coronary artery lesions. Direct stenting, particularly in conjunction with transradial intervention (TRI), has been associated with reduced bleeding complications, procedure time, radiation exposure and contrast administration compared to conventional stenting with wiring and predilatation. The low-profile Svelte IDS is designed to facilitate TRI and direct stenting, reducing the number of procedural steps, time and cost associated with coronary stenting. DIRECT II was a prospective, multicentre trial which enrolled 159 patients to establish non-inferiority of the Svelte IDS versus Resolute Integrity using a 2:1 randomisation. The primary endpoint was angiographic in-stent late lumen loss (LLL) at six months. Target vessel failure (TVF), as well as secondary clinical endpoints, will be assessed annually up to five years. At six months, in-stent LLL was 0.09±0.31 mm in the Svelte IDS group compared to 0.13±0.27 mm in the Resolute Integrity group (p<0.001 for non-inferiority). TVF at one year was similar across the Svelte IDS and Resolute Integrity groups (6.5% vs. 9.8%, respectively). DIRECT II demonstrated the non-inferiority of the Svelte IDS to Resolute Integrity with respect to in-stent LLL at six months. Clinical outcomes at one year were comparable between the two groups.

  7. Outcomes after unrestricted use of everolimus-eluting and sirolimus-eluting stents in routine clinical practice: a multicenter, prospective cohort study.

    PubMed

    Park, Duk-Woo; Kim, Young-Hak; Song, Hae-Geun; Ahn, Jung-Min; Kim, Won-Jang; Lee, Jong-Young; Kang, Soo-Jin; Lee, Seung-Whan; Lee, Cheol Whan; Park, Seong-Wook; Yun, Sung-Cheol; Her, Sung Ho; Hur, Seung Ho; Park, Jin Sik; Kim, Myeong-Kon; Choi, Yun Seok; Kim, Hyun Sook; Cho, Jang-Hyun; Lee, Sang Gon; Park, Yong Whi; Jeong, Myung-Ho; Lee, Bong Ki; Lee, Nae-Hee; Lim, Do-Sun; Yoon, Junghan; Seung, Ki Bae; Shin, Won-Yong; Rha, Seung-Woon; Kim, Kee-Sik; Tahk, Seung-Jea; Park, Byoung Eun; Ahn, Taehoon; Yang, Joo-Young; Jeong, Yong Seok; Rhew, Jay-Hyun; Park, Seung-Jung

    2012-06-01

    It remains unclear whether there are differences in the safety and efficacy outcomes between everolimus-eluting stents (EES) and sirolimus-eluting stents (SES) in contemporary practice. We prospectively enrolled 6166 consecutive patients who received EES (3081 patients) and SES (3085 patients) between April 2008 and June 2010, using data from the Interventional Cardiology Research In-Cooperation Society-Drug-Eluting Stents Registry. The primary end point was a composite of death, nonfatal myocardial infarction (MI), or target-vessel revascularization (TVR). At 2 years of follow-up, the 2 study groups did not differ significantly in crude risk of the primary end point (12.1% for EES versus 12.4% for SES; HR, 0.97; 95% CI, 0.84-1.12, P=0.66). After adjustment for differences in baseline risk factors, the adjusted risk for the primary end point remained similar for the 2 stent types (HR, 0.96; 95% CI, 0.82-1.12, P=0.60). There were also no differences between the stent groups in the adjusted risks of the individual component of death (HR, 0.93; 95% CI, 0.67-1.30, P=0.68), MI (HR, 0.97; 95% CI, 0.79-1.18, P=0.74), and TVR (HR, 1.10; 95% CI, 0.82-1.49, P=0.51). The adjusted risk of stent thrombosis also was similar (HR, 1.16; 95% CI, 0.47-2.84, P=0.75). In contemporary practice of percutaneous coronary intervention procedures, the unrestricted use of EES and SES showed similar rates of safety and efficacy outcomes with regard to death, MI, sent thrombosis, and TVR. Future longer-term follow-up is needed to better define the relative benefits of these drug-eluting stents. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01070420.

  8. Impact of the Distance from the Stent Edge to the Residual Plaque on Edge Restenosis following Everolimus-Eluting Stent Implantation

    PubMed Central

    Myojo, Masahiro; Sawaki, Daigo; Iwata, Hiroshi; Kiyosue, Arihiro; Higashikuni, Yasutomi; Tanaka, Tomofumi; Fujita, Daishi; Ando, Jiro; Fujita, Hideo; Hirata, Yasunobu; Komuro, Issei

    2015-01-01

    Objectives This study aimed to assess the relation between stent edge restenosis (SER) and the distance from the stent edge to the residual plaque using quantitative intravascular ultrasound. Background Although percutaneous coronary intervention with drug-eluting stents has improved SER rates, determining an appropriate stent edge landing zone can be challenging in cases of diffuse plaque lesions. It is known that edge vascular response can occur within 2 mm from the edge of a bare metal stent, but the distance to the adjacent plaque has not been evaluated for drug-eluting stents. Methods A total of 97 proximal residual plaque lesions (plaque burden [PB] >40%) treated with everolimus-eluting stents were retrospectively evaluated to determine the distance from the stent edge to the residual plaque. Results The SER group had significantly higher PB (59.1 ± 6.1% vs. 51.9 ± 9.1% for non-SER; P = 0.04). Higher PB was associated with SER, with the cutoff value of 54.74% determined using receiver operating characteristic (ROC) curve analysis. At this cutoff value of PB, the distance from the stent edge to the lesion was significantly associated with SER (odds ratio = 2.05, P = 0.035). The corresponding area under the ROC curve was 0.725, and the cutoff distance value for predicting SER was 1.0 mm. Conclusion An interval less than 1 mm from the proximal stent edge to the nearest point with the determined PB cutoff value of 54.74% was significantly associated with SER in patients with residual plaque lesions. PMID:25775115

  9. Impact of the distance from the stent edge to the residual plaque on edge restenosis following everolimus-eluting stent implantation.

    PubMed

    Takahashi, Masao; Miyazaki, Susumu; Myojo, Masahiro; Sawaki, Daigo; Iwata, Hiroshi; Kiyosue, Arihiro; Higashikuni, Yasutomi; Tanaka, Tomofumi; Fujita, Daishi; Ando, Jiro; Fujita, Hideo; Hirata, Yasunobu; Komuro, Issei

    2015-01-01

    This study aimed to assess the relation between stent edge restenosis (SER) and the distance from the stent edge to the residual plaque using quantitative intravascular ultrasound. Although percutaneous coronary intervention with drug-eluting stents has improved SER rates, determining an appropriate stent edge landing zone can be challenging in cases of diffuse plaque lesions. It is known that edge vascular response can occur within 2 mm from the edge of a bare metal stent, but the distance to the adjacent plaque has not been evaluated for drug-eluting stents. A total of 97 proximal residual plaque lesions (plaque burden [PB] >40%) treated with everolimus-eluting stents were retrospectively evaluated to determine the distance from the stent edge to the residual plaque. The SER group had significantly higher PB (59.1 ± 6.1% vs. 51.9 ± 9.1% for non-SER; P = 0.04). Higher PB was associated with SER, with the cutoff value of 54.74% determined using receiver operating characteristic (ROC) curve analysis. At this cutoff value of PB, the distance from the stent edge to the lesion was significantly associated with SER (odds ratio = 2.05, P = 0.035). The corresponding area under the ROC curve was 0.725, and the cutoff distance value for predicting SER was 1.0 mm. An interval less than 1 mm from the proximal stent edge to the nearest point with the determined PB cutoff value of 54.74% was significantly associated with SER in patients with residual plaque lesions.

  10. Drug-eluting stents versus bare-metal stents for off-label indications: a propensity score-matched outcome study.

    PubMed

    Austin, David; Oldroyd, Keith G; McConnachie, Alex; Slack, Rachel; Eteiba, Hany; Flapan, Andrew D; Jennings, Kevin P; Northcote, Robin J; Pell, Alastair C H; Starkey, Ian R; Pell, Jill P

    2008-08-01

    The US Food and Drug Administration recently concluded that data on off-label drug-eluting stent (DES) safety are limited. However, in actual clinical practice, DES are often used for off-label indications, and observational studies demonstrate that complications are higher when compared with on-label use. We aimed to determine whether clinical outcomes differ after DES and bare-metal stent implantation in a patient cohort defined by DES off-label indications. We used the national revascularization registry in Scotland to identify patients who underwent coronary stenting for an off-label indication between January 2003 and September 2005. Individual-level linkage to comprehensive national admission and death databases was used to ascertain the end points of death, myocardial infarction, and target-vessel revascularization. We calculated propensity scores on the basis of clinical, demographic, and angiographic variables and matched DES to bare-metal stents on a 1:1 basis. The final study population consisted of 1642 patients, well matched for important covariables at baseline. Event-free survival was calculated over 24 months with the Kaplan-Meier method. All-cause death was more common after bare-metal stent implantation during follow-up (7.7% versus 6.6%; hazard ratio 0.63; 95% confidence interval, 0.40 to 0.99; P=0.04). No difference in the rates of myocardial infarction were noted (7.3% versus 7.5%; hazard ratio 1.02; 95% confidence interval, 0.69 to 1.54; P=0.92). Target-vessel revascularization was reduced in patients treated with DES (13.9% versus 10.7%; hazard ratio 0.67; 95% confidence interval, 0.49 to 0.93; P=0.02). At 24 months, patients treated with DES for off-label indications had lower rates of death and target-vessel revascularization and similar rates of myocardial infarction, as compared with patients treated with bare-metal stents.

  11. Drug-eluting biodegradable ureteral stent: New approach for urothelial tumors of upper urinary tract cancer.

    PubMed

    Barros, Alexandre A; Browne, Shane; Oliveira, Carlos; Lima, Estevão; Duarte, Ana Rita C; Healy, Kevin E; Reis, Rui L

    2016-11-20

    Upper urinary tract urothelial carcinoma (UTUC) accounts for 5-10% of urothelial carcinomas and is a disease that has not been widely studied as carcinoma of the bladder. To avoid the problems of conventional therapies, such as the need for frequent drug instillation due to poor drug retention, we developed a biodegradable ureteral stent (BUS) impregnated by supercritical fluid CO 2 (scCO 2 ) with the most commonly used anti-cancer drugs, namely paclitaxel, epirubicin, doxorubicin, and gemcitabine. The release kinetics of anti-cancer therapeutics from drug-eluting stents was measured in artificial urine solution (AUS). The in vitro release showed a faster release in the first 72h for the four anti-cancer drugs, after this time a plateau was achieved and finally the stent degraded after 9days. Regarding the amount of impregnated drugs by scCO 2 , gemcitabine showed the highest amount of loading (19.57μg drug /mg polymer: 2% loaded), while the lowest amount was obtained for paclitaxel (0.067μg drug /mg polymer : 0.01% loaded). A cancer cell line (T24) was exposed to graded concentrations (0.01-2000ng/ml) of each drugs for 4 and 72h to determine the sensitivities of the cells to each drug (IC 50 ). The direct and indirect contact study of the anti-cancer biodegradable ureteral stents with the T24 and HUVEC cell lines confirmed the anti-tumoral effect of the BUS impregnated with the four anti-cancer drugs tested, reducing around 75% of the viability of the T24 cell line after 72h and demonstrating minimal cytotoxic effect on HUVECs. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Impact of bioresorbable versus permanent polymer on longterm vessel wall inflammation and healing: a comparative drug-eluting stent experimental study.

    PubMed

    Wilson, Gregory J; McGregor, Jennifer; Conditt, Gerard; Shibuya, Masahiko; Sushkova, Natalia; Eppihimer, Michael J; Hawley, Steven P; Rouselle, Serge D; Huibregtse, Barbara A; Dawkins, Keith D; Granada, Juan F

    2018-02-20

    Drug-eluting stents (DES) have evolved to using bioresorbable polymers as a method of drug delivery. The impact of bioresorbable polymer on long-term neointimal formation, inflammation, and healing has not been fully characterised. This study aimed to evaluate the biological effect of polymer resorption on vascular healing and inflammation. A comparative DES study was performed in the familial hypercholesterolaemic swine model of coronary stenosis. Permanent polymer DES (zotarolimus-eluting [ZES] or everolimus-eluting [EES]) were compared to bioresorbable polymer everolimus-eluting stents (BP-EES) and BMS. Post implantation in 29 swine, stents were explanted and analysed up to 180 days. Area stenosis was reduced in all DES compared to BMS at 30 days. At 180 days, BP-EES had significantly lower area stenosis than EES or ZES. Severe inflammatory activity persisted in permanent polymer DES at 180 days compared to BP-EES or BMS. Qualitative para-strut inflammation areas (graded as none to severe) were elevated but similar in all groups at 30 days, peaked at 90 days in DES compared to BMS (p<0.05) and, at 180 days, were similar between BMS and BP-EES but were significantly greater in DES. BP-EES resulted in a lower net long-term reduction in neointimal formation and inflammation compared to permanent polymer DES in an animal model. Further study of the long-term neointima formation deserves study in human clinical trials.

  13. Dual Antiplatelet Therapy for 6 Months vs 12 Months After New-generation Drug-eluting Stent Implantation: Matched Analysis of ESTROFA-DAPT and ESTROFA-2.

    PubMed

    de la Torre Hernández, José M; Oteo Domínguez, Juan F; Hernández, Felipe; García Camarero, Tamara; Abdul-Jawad Altisent, Omar; Rivero Crespo, Fernando; Cascón, José D; Zavala, Germán; Gimeno, Federico; Arrebola Moreno, Antonio L; Andraka, Leire; Gómez Menchero, Antonio; Bosa, Francisco; Carrillo, Xavier; Sánchez Recalde, Ángel; Alfonso, Fernando; Pérez de Prado, Armando; López Palop, Ramón; Sanchis, Juan; Diarte de Miguel, José A; Jiménez Navarro, Manuel; Muñoz, Luz; Ramírez Moreno, Antonio; Tizón Marcos, Helena

    2015-10-01

    The recommendation for dual antiplatelet therapy following drug-eluting stent implantation ranges from 6 months to 12 months or beyond. Recent trials have suggested the safety of a 6-month dual antiplatelet therapy regimen, yet certain caveats to these studies limit the applicability of this shorter duration dual antiplatelet therapy strategy in real world settings. A registry was constructed with consecutive recruitment of patients undergoing new-generation drug-eluting stent implantation and prescribed 6 months of dual antiplatelet therapy. Propensity score matching was undertaken with a historical cohort of patients treated with second-generation drug-eluting stents who received 12 months of dual antiplatelet therapy from the ESTROFA-2 registry. The sample size was calculated using a noninferiority basis and the primary endpoint was the combination of cardiac death, myocardial infarction, revascularization, or major bleeding at 12 months. The analysis included 1286 patients in each group, with no significant differences in baseline characteristics. The primary endpoint occurred in 5.0% and 6.6% in the 6-month and 12-month groups, respectively (P = .001 for noninferiority). The incidence of definite or probable stent thrombosis was 0.5% and 0.7% in the 6-month and 12-month groups, respectively (P = .4). Major bleeding events were lower in the 6-month group than in the 12-month group (0.8% vs 1.4%; P = .2) CONCLUSIONS: In selected patients in this large multicenter study, the safety and efficacy of a 6-month dual antiplatelet therapy regimen after implantation of new-generation drug-eluting stents appeared to be noninferior to those of a 12-month dual antiplatelet therapy regimen. Copyright © 2015 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  14. Variability in utilization of drug eluting stents in United States: Insights from nationwide inpatient sample.

    PubMed

    Panaich, Sidakpal S; Badheka, Apurva O; Arora, Shilpkumar; Patel, Nileshkumar J; Thakkar, Badal; Patel, Nilay; Singh, Vikas; Chothani, Ankit; Deshmukh, Abhishek; Agnihotri, Kanishk; Jhamnani, Sunny; Lahewala, Sopan; Manvar, Sohilkumar; Panchal, Vinaykumar; Patel, Achint; Patel, Neil; Bhatt, Parth; Savani, Chirag; Patel, Jay; Savani, Ghanshyambhai T; Solanki, Shantanu; Patel, Samir; Kaki, Amir; Mohamad, Tamam; Elder, Mahir; Kondur, Ashok; Cleman, Michael; Forrest, John K; Schreiber, Theodore; Grines, Cindy

    2016-01-01

    We studied the trends and predictors of drug eluting stent (DES) utilization from 2006 to 2011 to further expound the inter-hospital variability in their utilization. We queried the Healthcare Cost and Utilization Project's Nationwide Inpatient Sample (NIS) between 2006 and 2011 using ICD-9-CM procedure code, 36.06 (bare metal stent) or 36.07 (drug eluting stents) for Percutaneous Coronary Intervention (PCI). Annual hospital volume was calculated using unique identification numbers and divided into quartiles for analysis. We built a hierarchical two level model adjusted for multiple confounding factors, with hospital ID incorporated as random effects in the model. About 665,804 procedures (weighted n = 3,277,884) were analyzed. Safety concerns arising in 2006 reduced utilization DES from 90% of all PCIs performed in 2006 to a nadir of 69% in 2008 followed by increase (76% of all stents in 2009) and plateau (75% in 2011). Significant between-hospital variation was noted in DES utilization irrespective of patient or hospital characteristics. Independent patient level predictors of DES were (OR, 95% CI, P-value) age (0.99, 0.98-0.99, <0.001), female(1.12, 1.09-1.15, <0.001), acute myocardial infarction(0.75, 0.71-0.79, <0.001), shock (0.53, 0.49-0.58, <0.001), Charlson Co-morbidity index (0.81,0.77-0.86, <0.001), private insurance/HMO (1.27, 1.20-1.34, <0.001), and elective admission (1.16, 1.05-1.29, <0.001). Highest quartile hospital (1.64, 1.25-2.16, <0.001) volume was associated with higher DES placement. There is significant between-hospital variation in DES utilization and a higher annual hospital volume is associated with higher utilization rate of DES. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  15. A Randomized Comparison of Reservoir-Based Polymer-Free Amphilimus-Eluting Stents Versus Everolimus-Eluting Stents With Durable Polymer in Patients With Diabetes Mellitus: The RESERVOIR Clinical Trial.

    PubMed

    Romaguera, Rafael; Gómez-Hospital, Joan A; Gomez-Lara, Josep; Brugaletta, Salvatore; Pinar, Eduardo; Jiménez-Quevedo, Pilar; Gracida, Montserrat; Roura, Gerard; Ferreiro, Jose L; Teruel, Luis; Montanya, Eduard; Fernandez-Ortiz, Antonio; Alfonso, Fernando; Valgimigli, Marco; Sabate, Manel; Cequier, Angel

    2016-01-11

    The aim of this study was to compare the efficacy of amphilimus-eluting stents (AES) with that of everolimus-eluting stents (EES) in patients with diabetes mellitus (DM). The AES is a polymer-free drug-eluting stent that elutes sirolimus formulated with an amphiphilic carrier from laser-dug wells. This technology could be associated with a high efficacy in patients with DM. This was a multicenter, randomized, noninferiority trial. Patients with DM medically treated with oral glucose-lowering agents or insulin and de novo coronary lesions were randomized in a 1:1 fashion to AES or EES. The primary endpoint was the neointimal (NI) volume obstruction assessed by optical coherence tomography at 9-month follow-up. A total of 116 lesions in 112 patients were randomized. Overall, 40% were insulin-treated patients, with a median HbA1c of 7.3% (interquartile range: 6.7% to 8.0%). The primary endpoint, NI volume obstruction, was 11.97 ± 5.94% for AES versus 16.11 ± 18.18% for EES, meeting the noninferiority criteria (p = 0.0003). Pre-specified subgroup analyses showed a significant interaction between stent type and glycemic control (p = 0.02), with a significant reduction in NI hyperplasia in the AES group in patients with the higher HbA1c (p = 0.03). By quantitative coronary angiography, in-stent late loss was 0.14 ± 0.24 for AES versus 0.24 ± 0.57 mm for EES (p = 0.27), with a larger minimal lumen diameter at follow-up for AES (p = 0.02), mainly driven by 2 cases of occlusive restenosis in the EES group. AES are noninferior to EES for the coronary revascularization of patients with DM. These results suggest a high efficacy of the AES and may support the potential benefit of this stent in patients with DM. (A Randomized Comparison of Reservoir-Based Polymer-Free Amphilimus-Eluting Stents Versus Everolimus-Eluting Stents With Durable Polymer in Patients With Diabetes Mellitus [RESERVOIR]; NCT01710748). Copyright © 2016 American College of Cardiology Foundation

  16. Comparison of everolimus- and paclitaxel-eluting stents in patients with acute and stable coronary syndromes: pooled results from the SPIRIT (A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) and COMPARE (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice) Trials.

    PubMed

    Planer, David; Smits, Pieter C; Kereiakes, Dean J; Kedhi, Elvin; Fahy, Martin; Xu, Ke; Serruys, Patrick W; Stone, Gregg W

    2011-10-01

    This study sought to compare the clinical outcomes of everolimus-eluting stents (EES) versus paclitaxel-eluting stents (PES) in patients with acute coronary syndromes (ACS) and stable coronary artery disease (CAD). Although randomized trials have shown superiority of EES to PES, the safety and efficacy of EES in ACS is unknown. We performed a patient-level pooled analysis from the prospective, randomized SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) II, III, IV, and COMPARE (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice) trials in which 2,381 patients with ACS and 4,404 patients with stable CAD were randomized to EES or to PES. Kaplan-Meier estimates of death, myocardial infarction (MI), ischemia-driven target lesion revascularization, and stent thrombosis were assessed at 2 years and stratified by clinical presentation (ACS vs. stable CAD). At 2 years, patients with ACS compared with stable CAD had higher rates of death (3.2% vs. 2.4%, hazard ratio [HR]: 1.37 [95% confidence interval (CI): 1.02 to 1.85], p = 0.04) and MI (4.9% vs. 3.4%, HR: 1.45 [95% CI: 1.14 to 1.85], p = 0.02). In patients with ACS, EES versus PES reduced the rate of death or MI (6.6% vs. 9.3%, HR: 0.70 [95% CI: 0.52 to 0.94], p = 0.02), stent thrombosis (0.7% vs. 2.9%, HR: 0.25 [95% CI: 0.12 to 0.52], p = 0.0002), and ischemia-driven target lesion revascularization (4.7% vs. 6.2%, HR: 0.69 [95% CI: 0.48 to 0.99], p = 0.04). In patients with stable CAD, EES reduced the rate of death or MI (4.5% vs. 7.1%, HR: 0.62 [95% CI: 0.48 to 0.80], p = 0.0002), stent thrombosis (0.7% vs. 1.8%, HR: 0.34 [95% CI: 0.19 to 0.62], p = 0.0002), and ischemia-driven target lesion revascularization (3.9% vs. 6.9%, HR: 0.55 [95% CI: 0.42 to 0.73], p < 0.0001). Treatment with EES versus PES provides enhanced safety and efficacy regardless of the acuity of the clinical syndrome being treated and appears to

  17. Patient-Centered Tablet Application for Improving Medication Adherence after a Drug-Eluting Stent.

    PubMed

    Shah, Vicki; Dileep, Anandu; Dickens, Carolyn; Groo, Vicki; Welland, Betty; Field, Jerry; Baumann, Matthew; Flores, Jose D; Shroff, Adhir; Zhao, Zhongsheng; Yao, Yingwei; Wilkie, Diana J; Boyd, Andrew D

    2016-01-01

    This study's objective was to evaluate a patient-centered educational electronic tablet application, "My Interventional Drug-Eluting Stent Educational App" (MyIDEA) to see if there was an increase in patient knowledge about dual antiplatelet therapy (DAPT) and medication possession ratio (MPR) compared to treatment as usual. In a pilot project, 24 elderly (≥50 years old) research participants were recruited after a drug-eluting stent. Eleven were randomized to the control arm and 13 to the interventional arm. All the participants completed psychological and knowledge questionnaires. Adherence was assessed through MPR, which was calculated at 3 months for all participants who were scheduled for second and third follow-up visits. Relative to control, the interventional group had a 10% average increase in MPR. As compared to the interventional group, more patients in the control group had poor adherence (<80% MPR). The psychological data revealed a single imbalance in anxiety between the control and interventional groups. On average, interventional participants spent 21 min using MyIDEA. Consumer health informatics has enabled us to engage patients with their health data using novel methods. Consumer health technology needs to focus more on patient knowledge and engagement to improve long-term health. MyIDEA takes a unique approach in targeting DAPT from the onset. MyIDEA leverages patient-centered information with clinical care and the electronic health record highlighting the patients' role as a team member in their own health care. The patients think critically about adverse events and how to solve issues before leaving the hospital.

  18. Impact of an endothelial progenitor cell capturing stent on coronary microvascular function: comparison with drug-eluting stents.

    PubMed

    Choi, Woong Gil; Kim, Soo Hyun; Yoon, Hyung Seok; Lee, Eun Joo; Kim, Dong Woon

    2015-01-01

    Although drug-eluting stents (DESs) effectively reduce restenosis following percutaneous coronary intervention (PCI), they also delay re-endothelialization and impair microvascular function, resulting in adverse clinical outcomes. Endothelial progenitor cell (EPC) capturing stents, by providing a functional endothelial layer on the stent, have beneficial effects on microvascular function. However, data on coronary microvascular function in patients with EPC stents versus DESs are lacking. Seventy-four patients who previously underwent PCI were enrolled in this study. Microvascular function was evaluated 6 months after PCI based on the index of microvascular resistance (IMR) and the coronary flow reserve (CFR). IMR was calculated as the ratio of the mean distal coronary pressure at maximal hyperemia to the inverse of the hyperemic mean transit time (hTmn). The CFR was calculated by dividing the hTmn by the baseline mean transit time. Twenty-one patients (age, 67.2 ± 9.6 years; male:female, 15:6) with an EPC stent and 53 patients (age, 61.5 ± 14.7 years; male:female, 40:13) with second-generation DESs were included in the study. There were no significant differences in the baseline clinical and angiographic characteristics of the two groups. Angiography performed 6 months postoperatively did not show significant differences in their CFR values. However, patients with the EPC stent had a significantly lower IMR than patients with second-generation DESs (median, 25.5 [interquartile range, 12.85 to 28.18] vs. 29.0 [interquartile range, 15.42 to 39.23]; p = 0.043). Microvascular dysfunction was significantly improved after 6 months in patients with EPC stents compared to those with DESs. The complete re-endothelialization achieved with the EPC stent may provide clinical benefits over DESs, especially in patients with microvascular dysfunction.

  19. Three-year patient-related and stent-related outcomes of second-generation everolimus-eluting Xience V stents versus zotarolimus-eluting resolute stents in real-world practice (from the Multicenter Prospective EXCELLENT and RESOLUTE-Korea Registries).

    PubMed

    Lee, Joo Myung; Park, Kyung Woo; Han, Jung-Kyu; Yang, Han-Mo; Kang, Hyun-Jae; Koo, Bon-Kwon; Bae, Jang-Whan; Woo, Sung-Il; Park, Jin Sik; Jin, Dong-Kyu; Jeon, Dong Woon; Oh, Seok Kyu; Park, Jong-Seon; Kim, Doo-Il; Hyon, Min Su; Jeon, Hui-Kyung; Lim, Do-Sun; Kim, Myeong-Gon; Rha, Seung-Woon; Her, Sung-Ho; Hwang, Jin-Yong; Kim, Sanghyun; Choi, Young Jin; Kang, Jin Ho; Moon, Keon-Woong; Jang, Yangsoo; Kim, Hyo-Soo

    2014-11-01

    Long-term outcomes are imperative to confirm safety of drug-eluting stents. There have been 2 randomized controlled trials comparing everolimus-eluting stents (EESs) and Resolute zotarolimus-eluting stents (ZES-Rs). To date, long-term clinical outcomes of these stents were limited to only 1 report, which has recently reported 4-year comparisons of these stents. Therefore, more evidence is needed regarding long-term clinical outcomes of the second-generation stents. This study compared the long-term clinical outcomes of EES with ZES-R in "all-comer" cohorts up to 3-year follow-up. The EXCELLENT and RESOLUTE-Korea registries prospectively enrolled 3,056 patients treated with EES and 1,998 with ZES-R, respectively, without exclusions. Stent-related composite outcomes (target lesion failure) and patient-related composite events up to 3-year follow-up were compared in crude and propensity score-matched analyses. Of 5,054 patients, 3,830 patients (75.8%) had off-label indication (2,217 treated with EES and 1,613 treated with ZES-R). The stent-related outcome (189 [6.2%] vs 127 [6.4%], p = 0.812) and the patient-related outcome (420 [13.7%] vs 250 [12.5%], p = 0.581) did not differ between EES and ZES-R, respectively, at 3 years, which was corroborated by similar results from the propensity score-matched cohort (hazard ratio [HR] 0.92, 95% confidence interval [CI] 0.70 to 1.20, p = 0.523 and 0.85, 95% CI 0.70 to 1.02, p = 0.081, for stent- and patient-related outcomes, respectively). The rate of definite or probable stent thrombosis up to 3 years (22 [0.7%] vs 10 [0.5%], p = 0.370) was also similar. The rate of very late definite or probable stent thrombosis was very low and comparable between the 2 stents (3 [0.1%] vs 1 [0.1%], p = 0.657). In multivariate analysis, chronic renal failure (adjusted HR 3.615, 95% CI 2.440 to 5.354, p <0.001) and off-label indication (adjusted HR 1.782, 95% CI 1.169 to 2.718, p = 0.007) were the strongest predictors of target

  20. Disappearing and reappearing differences in drug-eluting stent use by race.

    PubMed

    Federspiel, Jerome J; Stearns, Sally C; Reiter, Kristin L; Geissler, Kimberley H; Triplette, Matthew A; D'Arcy, Laura P; Sheridan, Brett C; Rossi, Joseph S

    2013-04-01

    Drug-eluting coronary stents (DES) rapidly dominated the marketplace in the United States after approval in 2003, but utilization rates were initially lower among African American patients. We assess whether racial differences persisted as DES diffused into practice. Medicare claims data were used to identify coronary stenting procedures among elderly patients with acute coronary syndromes (ACS). Regression models of the choice of DES versus bare mental stent controlled for demographics, ACS type, co-morbidities and hospital characteristics. Diffusion was assessed in the short run (2003-2004) and long run (2007), with the effect of race calculated to allow for time-varying effects. The sample included 381,887 Medicare beneficiaries treated with stent insertion; approximately 5% were African American. Initially (May 2003-February 2004), African American race was associated with lower DES use compared to other races (44.3% versus 46.5%, P < 0.01). Once DES usage was high in all patients (March-December 2004), differences were not significant (79.8% versus 80.3%, P = 0.45). Subsequent concerns regarding DES safety caused reductions in DES use, with African Americans having lower use than other racial groups in 2007 (63.1% versus 65.2%, P < 0.01). Racial disparities in DES use initially disappeared during a period of rapid diffusion and high usage rates; the reappearance of disparities in use by 2007 may reflect DES use tailored to unmeasured aspects of case mix and socio-economic status. Further work is needed to understand whether underlying differences in race reflect decisions regarding treatment appropriateness. © 2011 Blackwell Publishing Ltd.

  1. Highly porous drug-eluting structures

    PubMed Central

    Elsner, Jonathan J.; Kraitzer, Amir; Grinberg, Orly; Zilberman, Meital

    2012-01-01

    For many biomedical applications, there is need for porous implant materials. The current article focuses on a method for preparation of drug-eluting porous structures for various biomedical applications, based on freeze drying of inverted emulsions. This fabrication process enables the incorporation of any drug, to obtain an “active implant” that releases drugs to the surrounding tissue in a controlled desired manner. Examples for porous implants based on this technique are antibiotic-eluting mesh/matrix structures used for wound healing applications, antiproliferative drug-eluting composite fibers for stent applications and local cancer treatment, and protein-eluting films for tissue regeneration applications. In the current review we focus on these systems. We show that the release profiles of both types of drugs, water-soluble and water-insoluble, are affected by the emulsion's formulation parameters. The former's release profile is affected mainly through the emulsion stability and the resulting porous microstructure, whereas the latter's release mechanism occurs via water uptake and degradation of the host polymer. Hence, appropriate selection of the formulation parameters enables to obtain desired controllable release profile of any bioactive agent, water-soluble or water-insoluble, and also fit its physical properties to the application. PMID:23507890

  2. Combining clinical and angiographic variables for estimating risk of target lesion revascularization after drug eluting stent placement.

    PubMed

    Stolker, Joshua M; Cohen, David J; Kennedy, Kevin F; Pencina, Michael J; Arnold, Suzanne V; Kleiman, Neal S; Spertus, John A

    Drug-eluting stents (DES) reduce restenosis but require prolonged antiplatelet therapy, when compared with bare metal stents. Ideally, the patient should be involved in this risk:benefit assessment prior to selecting DES, to maximize the benefits and cost-effectiveness of care, and to improve medication adherence. However, accurate estimation of restenosis risk may require angiographic factors identified at cardiac catheterization. In a large PCI registry, we used logistic regression to identify clinical and angiographic predictors of clinically-driven target lesion revascularization (TLR) over the first year after stent placement. Discrimination c-statistic and integrated discrimination improvement (IDI) were used to calculate the incremental utility of angiographic variables when added to clinical predictors. Of 8501 PCI patients, TLR occurred in 4.5%. After adjusting for DES use, clinical TLR predictors were younger age, female sex, diabetes, prior PCI, and prior bypass surgery (model c-statistic 0.630). Angiographic predictors were vein graft PCI, in-stent restenosis lesion, longer stent length, and smaller stent diameter (c-statistic 0.650). After adding angiographic factors to the clinical model, c-statistic improved to 0.680 and the average separation in TLR risk among patients with and without TLR improved by 1% (IDI=0.010, 95% CI 0.009-0.014), primarily driven by those experiencing TLR (from 5.9% to 6.9% absolute risk). Among unselected PCI patients, the incidence of clinically-indicated TLR is <5% at 1-year, and standard clinical variables only moderately discriminate who will and will not experience TLR. Angiographic variables significantly improve TLR risk assessment, suggesting that stent selection may be best performed after coronary anatomy has been delineated. Although several recent studies have challenged traditional expectations regarding the duration of dual antiplatelet therapy, current guidelines recommend at least 6 to 12months of treatment

  3. The sirolimus-eluting Cypher Select coronary stent for the treatment of bare-metal and drug-eluting stent restenosis: insights from the e-SELECT (Multicenter Post-Market Surveillance) registry.

    PubMed

    Abizaid, Alexandre; Costa, J Ribamar; Banning, Adrian; Bartorelli, Antonio L; Dzavik, Vladimir; Ellis, Stephen; Gao, Runlin; Holmes, David R; Jeong, Muyng Ho; Legrand, Victor; Neumann, Franz-Josef; Nyakern, Maria; Orlick, Amy; Spaulding, Christian; Worthley, Stephen; Urban, Philip M

    2012-01-01

    This study sought to compare the 1-year safety and efficacy of Cypher Select or Cypher Select Plus (Cordis Corporation, Bridgewater, New Jersey) sirolimus-eluting stents (SES) with the treatment of bare-metal stents (BMS) and drug-eluting stent (DES) in-stent restenosis (ISR) in nonselected, real-world patients. There is paucity of consistent data on DES for the treatment of ISR, especially, DES ISR. The e-SELECT (Multicenter Post-Market Surveillance) registry is a Web-based, multicenter and international registry encompassing virtually all subsets of patients and lesions treated with at least 1 SES during the period from 2006 to 2008. We enrolled in this pre-specified subanalysis all patients with at least 1 clinically relevant BMS or DES ISR treated with SES. Primary endpoint was major adverse cardiac events and stent thrombosis rate at 1 year. Of 15,147 patients enrolled, 1,590 (10.5%) presented at least 1 ISR (BMS group, n = 1,235, DES group, n = 355). Patients with DES ISR had higher incidence of diabetes (39.4% vs. 26.9%, p < 0.001), renal insufficiency (5.8% vs. 2.3%, p = 0.003), and prior coronary artery bypass graft (20.5% vs. 11.8%, p < 0.001). At 1 year, death (1.4% for BMS vs. 2.1% for DES, p = 0.3) and myocardial infarction (2.4% for BMS and 3.3% for DES, p = 0.3) rates were similar, whereas ischemia-driven target lesion revascularization and definite/probable late stent thrombosis were higher in patients with DES ISR (6.9% vs. 3.1%, p = 0.003, and 1.8% vs. 0.5%, p = 0.04, respectively). Use of SES for either BMS or DES ISR treatment is safe and associated with low target lesion revascularization recurrence and no apparent safety concern. Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  4. Angiographic patterns of restenosis with 2nd generation drug-eluting stent: comparative analysis from a 10-year single-center experience .

    PubMed

    Lee, Sahmin; Yoon, Chang-Hwan; Oh, Il-Young; Suh, Jung-Won; Cho, Young-Seok; Cho, Goo-Yeong; Chae, In-Ho; Choi, Dong-Ju; Youn, Tae-Jin

    2015-01-01

    The angiographic features of restenosis contain prognostic information. However, restenosis patterns of the new generation drug-eluting stents (DES), everolimus-(EES) and resolute zotarolimus-eluting stent (ZES) have not been described.A total of 210 consecutive patients with DES restenosis were enrolled from 2003 to 2012. We analyzed 217 restenotic lesions after DES implantation, and compared the morphologic characteristics of the 2nd generation DES restenosis to those of restenosis with 2 first generation DES, sirolimus-(SES) and paclitaxel-eluting stent (PES).Baseline characteristics were comparable between the different stent groups. The incidence of focal restenosis was significantly lower for PES than the other stents (49.5% versus 87.0%, 76.2%, and 82.1% for PES versus SES, EES, and ZES, respectively, P < 0.001). When considering the pattern of restenosis solely within the stent margins, a further clear distinction between PES and other stents was observed (40.0% versus 92.9%, 88.9%, and 81.2% in PES versus SES, EES, and ZES, respectively, P < 0.001). There were no significant differences in restenosis patterns among SES, EES, and ZES. In multivariate analysis, PES implantation, hypertension, and age were associated with non-focal type of restenosis after DES implantation. After the introduction of EES and ZES into routine clinical practice in 2008, focal restenosis significantly increased from 63.9% to 76.7% and diffuse restenosis significantly decreased from 26.4% to 11.0% (P = 0.045).Focal restenosis was the most common pattern of restenosis in the new generation DES and the incidence of diffuse restenosis significantly decreased with the introduction of the 2nd generation DES.

  5. Stent Thrombosis in Drug-Eluting or Bare-Metal Stents in Patients Receiving Dual Antiplatelet Therapy.

    PubMed

    Kereiakes, Dean J; Yeh, Robert W; Massaro, Joseph M; Driscoll-Shempp, Priscilla; Cutlip, Donald E; Steg, P Gabriel; Gershlick, Anthony H; Darius, Harald; Meredith, Ian T; Ormiston, John; Tanguay, Jean-François; Windecker, Stephan; Garratt, Kirk N; Kandzari, David E; Lee, David P; Simon, Daniel I; Iancu, Adrian Corneliu; Trebacz, Jaroslaw; Mauri, Laura

    2015-10-01

    This study sought to compare rates of stent thrombosis and major adverse cardiac and cerebrovascular events (MACCE) (composite of death, myocardial infarction, or stroke) after coronary stenting with drug-eluting stents (DES) versus bare-metal stents (BMS) in patients who participated in the DAPT (Dual Antiplatelet Therapy) study, an international multicenter randomized trial comparing 30 versus 12 months of dual antiplatelet therapy in subjects undergoing coronary stenting with either DES or BMS. Despite antirestenotic efficacy of coronary DES compared with BMS, the relative risk of stent thrombosis and adverse cardiovascular events is unclear. Many clinicians perceive BMS to be associated with fewer adverse ischemic events and to require shorter-duration dual antiplatelet therapy than DES. Prospective propensity-matched analysis of subjects enrolled into a randomized trial of dual antiplatelet therapy duration was performed. DES- and BMS-treated subjects were propensity-score matched in a many-to-one fashion. The study design was observational for all subjects 0 to 12 months following stenting. A subset of eligible subjects without major ischemic or bleeding events were randomized at 12 months to continued thienopyridine versus placebo; all subjects were followed through 33 months. Among 10,026 propensity-matched subjects, DES-treated subjects (n = 8,308) had a lower rate of stent thrombosis through 33 months compared with BMS-treated subjects (n = 1,718, 1.7% vs. 2.6%; weighted risk difference -1.1%, p = 0.01) and a noninferior rate of MACCE (11.4% vs. 13.2%, respectively, weighted risk difference -1.8%, p = 0.053, noninferiority p < 0.001). DES-treated subjects have long-term rates of stent thrombosis that are lower than BMS-treated subjects. (The Dual Antiplatelet Therapy Study [DAPT study]; NCT00977938). Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  6. Coronary Artery Bypass Surgery Versus Drug-Eluting Stent Implantation for Left Main or Multivessel Coronary Artery Disease: A Meta-Analysis of Individual Patient Data.

    PubMed

    Lee, Cheol Whan; Ahn, Jung-Min; Cavalcante, Rafael; Sotomi, Yohei; Onuma, Yoshinobu; Suwannasom, Pannipa; Tenekecioglu, Erhan; Yun, Sung-Cheol; Park, Duk-Woo; Kang, Soo-Jin; Lee, Seung-Whan; Kim, Young-Hak; Park, Seong-Wook; Serruys, Patrick W; Park, Seung-Jung

    2016-12-26

    The authors undertook a patient-level meta-analysis to compare long-term outcomes after coronary artery bypass grafting (CABG) versus percutaneous coronary intervention (PCI) with drug-eluting stents (DES) in 3,280 patients with left main or multivessel coronary artery disease (CAD). The relative efficacy and safety of CABG versus PCI with DES for left main or multivessel CAD remain controversial. Data were pooled from the BEST (Randomized Comparison of Coronary Artery Bypass Surgery and Everolimus Eluting Stent Implantation in the Treatment of Patients With Multivessel Coronary Artery Disease), PRECOMBAT (Premier of Randomized Comparison of Bypass Surgery vs. Angioplasty Using Sirolimus-Eluting Stent in Patients With Left Main Coronary Artery Disease), and SYNTAX (Synergy Between PCI With Taxus and Cardiac Surgery) trials. The primary outcome was a composite of all-cause death, myocardial infarction, or stroke. The median follow-up was 60 months, and follow-up was completed for 96.2% of patients. The rate of primary outcome was significantly lower with CABG than with PCI (13.0% vs. 16.0%; hazard ratio [HR]: 0.83; 95% confidence interval [CI]: 0.69 to 1.00; p = 0.046). The difference was mainly driven by reduction in myocardial infarction (HR: 0.46; 95% CI: 0.33 to 0.64; p < 0.001). There was significant interaction between treatment effect and types of CAD, showing CABG to be superior compared with PCI with DES in patients with multivessel CAD (p = 0.001), but no between-group difference in those with left main CAD (p = 0.427). The rates for all-cause death and stroke were similar between the 2 groups. By contrast, the need for repeat revascularization was significantly lower in the CABG group compared with the PCI group. CABG, as compared with PCI with DES, reduced long-term rates of the composite of all-cause death, myocardial infarction, or stroke in patients with left main or multivessel CAD. The advantage of CABG over PCI with DES was particularly

  7. Impact of Paclitaxel-Eluting Balloons Compared to Second-Generation Drug-Eluting Stents for of In-Stent Restenosis in a Primarily Acute Coronary Syndrome Population

    PubMed Central

    Marquis-Gravel, Guillaume; Matteau, Alexis; Potter, Brian J; Gobeil, François; Noiseux, Nicolas; Stevens, Louis-Mathieu; Mansour, Samer

    2017-01-01

    Background The place of drug-eluting balloons (DEB) in the treatment of in-stent restenosis (ISR) is not well-defined, particularly in a population of all-comers with acute coronary syndromes (ACS). Objective Compare the clinical outcomes of DEB with second-generation drug-eluting stents (DES) for the treatment of ISR in a real-world population with a high proportion of ACS. Methods A retrospective analysis of consecutive patients with ISR treated with a DEB compared to patients treated with a second-generation DES was performed. The primary endpoint was a composite of major adverse cardiovascular events (MACE: all-cause death, non-fatal myocardial infarction, and target lesion revascularization). Comparisons were performed using Cox proportional hazards multivariate adjustment and Kaplan-Meier analysis with log-rank. Results The cohort included 91 patients treated with a DEB and 89 patients treated with a DES (74% ACS). Median follow-up was 26 months. MACE occurred in 33 patients (36%) in the DEB group, compared to 17 patients (19%) in the DES group (p log-rank = 0.02). After multivariate adjustment, there was no significant difference between the groups (HR for DEB = 1.45 [95%CI: 0.75-2.83]; p = 0.27). Mortality rates at 1 year were 11% with DEB, and 3% with DES (p = 0.04; adjusted HR = 2.85 [95%CI: 0.98-8.32]; p = 0.06). Conclusion In a population with a high proportion of ACS, a non-significant numerical signal towards increased rates of MACE with DEB compared to second-generation DES for the treatment of ISR was observed, mainly driven by a higher mortality rate. An adequately-powered randomized controlled trial is necessary to confirm these findings. PMID:28977052

  8. Cost-effectiveness analysis of biodegradable polymer versus durable polymer drug-eluting stents incorporating real-world evidence.

    PubMed

    Teng, Monica; Zhao, Ying Jiao; Khoo, Ai Leng; Ananthakrishna, Rajiv; Yeo, Tiong Cheng; Lim, Boon Peng; Chan, Mark Y; Loh, Joshua P

    2018-06-05

    Compared with second-generation durable polymer drug-eluting stents (DP-DES), the cost-effectiveness of biodegradable polymer drug-eluting stents (BP-DES) remains unclear in the real-world setting. We assessed the cost-effectiveness of BP-DES in patients with coronary artery disease undergoing percutaneous coronary intervention (PCI). We developed a decision-analytic model to compare the cost-effectiveness of BP-DES to DP-DES over one year and five years from healthcare payer perspective. Relative treatment effects during the first year post-PCI were obtained from a real-world population analysis while clinical event risks in the subsequent four years were derived from a meta-analysis of published studies. At one year, based on the clinical data analysis of 497 propensity-score matched pairs of patients, BP-DES were associated with an incremental cost-effectiveness ratio (ICER) of USD20,503 per quality-adjusted life-year (QALY) gained. At five years, BP-DES yielded an ICER of USD4,062 per QALY gained. At the willingness-to-pay threshold of USD50,400 (one gross domestic product per capita in Singapore in 2015), BP-DES were cost-effective. Sensitivity analysis showed that the cost of stents had a significant impact on the cost-effectiveness of BP-DES. Threshold analysis demonstrated that if the cost difference between BP-DES and DP-DES exceeded USD493, BP-DES would not be cost-effective in patients with one-year of follow-up. BP-DES were cost-effective compared with DP-DES in patients with coronary artery disease at one year and five years after PCI. It is worth noting that the cost of stents had a significant impact on the findings. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  9. Economic evaluation of drug-eluting stents in coronary angioplasty.

    PubMed

    Santos, Ricardo; Pereira, Hélder

    2005-11-01

    Coronary angioplasty has revolutionized the treatment of coronary artery disease, from the first balloon angioplasty to the current era of drug-eluting stents (DES), which were developed to eliminate the bare metal stent's (BMS) Achilles' heel, restenosis. DES have an extremely low restenosis rate but are significantly more expensive and need more prolonged dual antiplatelet therapy. Restenosis has a generally benign prognosis and is not associated with higher mortality or major adverse cardiovascular events, which has limited the penetration of DES, whose only advantage is the reduction of restenosis. Economic evaluation of DES is therefore of paramount importance for assessing their appropriate use. In randomized trials in which they are compared with BMS, economic evaluation is advantageous for DES, with good cost-effectiveness ratios for both cost per quality-adjusted life year (QALY) and cost per revascularization avoided. However, these trials have two major limitations--the angiographic follow-up protocol and selection of patients with lower risk--and so their results do not accurately reflect reality. Other studies with unselected populations and cost-effectiveness models show that there is an economic advantage in the use of DES in groups with higher risk of restenosis, but not for the whole population undergoing angioplasty. Use of DES will be more appropriate if we can identify populations with a higher likelihood of restenosis, because these are the patients that will benefit most from their use and in whom they will be economically advantageous.

  10. Lesion length impacts long term outcomes of drug-eluting stents and bare metal stents differently.

    PubMed

    Chang, Shang-Hung; Chen, Chun-Chi; Hsieh, Ming-Jer; Wang, Chao-Yung; Lee, Cheng-Hung; Hsieh, I-Chang

    2013-01-01

    Long lesions have been associated with adverse outcomes in percutaneous coronary interventions with bare metal stents (BMS). However, the exact impact of lesion length on the short- and long-term outcomes of drug-eluting stent (DES) implantations is not as clear. This study compared the impact of lesion length on angiographic and clinical outcomes of BMS and DES in a single-center prospective registry. Lesion length was divided into tertiles. The primary endpoints were angiographically defined binary in-stent restenosis (ISR) rate and major adverse cardiac event (MACE). Of the 4,312 de novo lesions in 3,447 consecutive patients in the CAPTAIN registry, 2,791 lesions (of 2,246 patients) received BMS, and the remaining 1,521 lesions (of 1,201 patients) received DES. The mean follow-up duration was 4.5 years. The longer the lesion, the higher the ISR rate (14%, 18%, and 29%, p<0.001) and the lower the MACE-free survivals (p = 0.007) in the BMS group. However, lesion length showed no such correlation with ISR rates (4.7%, 3.3%, and 7.8%, p = 0.67) or MACE-free survivals (p = 0.19) in the DES group. In our single-center prospective registry, lesion length defined in tertiles has no impact on the short-term (ISR) or long-term (MACE) outcomes of patients implanted with DES. In contrast, longer lesion correlates with higher ISR and MACE rates in BMS group.

  11. Everolimus-eluting bioresorbable vascular scaffolds versus everolimus-eluting metallic stents: a meta-analysis of randomised controlled trials.

    PubMed

    Cassese, Salvatore; Byrne, Robert A; Ndrepepa, Gjin; Kufner, Sebastian; Wiebe, Jens; Repp, Janika; Schunkert, Heribert; Fusaro, Massimiliano; Kimura, Takeshi; Kastrati, Adnan

    2016-02-06

    Bioresorbable coronary stents might improve outcomes of patients treated with percutaneous coronary interventions. The everolimus-eluting bioresorbable vascular scaffold is the most studied of these stent platforms; however, its performance versus everolimus-eluting metallic stents remains poorly defined. We aimed to assess the efficacy and safety of everolimus-eluting bioresorbable vascular scaffolds versus everolimus-eluting metallic stents in patients with ischaemic heart disease treated with percutaneous revascularisation. We searched Medline, Embase, the Cochrane Central Register of Controlled Trials (CENTRAL), scientific sessions abstracts, and relevant websites for randomised trials investigating everolimus-eluting bioresorbable vascular scaffolds versus everolimus-eluting metallic stents published or posted between Nov 30, 2006, and Oct 12, 2015. The primary efficacy outcome was target lesion revascularisation and the primary safety outcome was definite or probable stent (scaffold) thrombosis. Secondary outcomes were target lesion failure (the composite of cardiac death, target-vessel myocardial infarction, or ischaemia-driven target lesion revascularisation), myocardial infarction, death, and in-device late lumen loss. We derived odds ratios (ORs) and weighted mean differences with 95% CIs, and calculated the risk estimates for the main outcomes according to a random-effects model. This study is registered with PROSPERO, number CRD42015026374. We included six trials, comprising data for 3738 patients randomised to receive percutaneous coronary intervention with either an everolimus-eluting bioresorbable vascular scaffold (n=2337) or an everolimus-eluting metallic stent (n=1401). Median follow-up was 12 months (IQR 9-12). Patients treated with bioresorbable vascular scaffolds had a similar risk of target lesion revascularisation (OR 0.97 [95% CI 0.66-1.43]; p=0.87), target lesion failure (1.20 [0.90-1.60]; p=0.21), myocardial infarction (1.36 [0.98-1.89]; p

  12. Improved safety and reduction in stent thrombosis associated with biodegradable polymer-based biolimus-eluting stents versus durable polymer-based sirolimus-eluting stents in patients with coronary artery disease: final 5-year report of the LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) randomized, noninferiority trial.

    PubMed

    Serruys, Patrick W; Farooq, Vasim; Kalesan, Bindu; de Vries, Ton; Buszman, Pawel; Linke, Axel; Ischinger, Thomas; Klauss, Volker; Eberli, Franz; Wijns, William; Morice, Marie Claude; Di Mario, Carlo; Corti, Roberto; Antoni, Diethmar; Sohn, Hae Y; Eerdmans, Pedro; Rademaker-Havinga, Tessa; van Es, Gerrit-Anne; Meier, Bernhard; Jüni, Peter; Windecker, Stephan

    2013-08-01

    This study sought to report the final 5 years follow-up of the landmark LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) trial. The LEADERS trial is the first randomized study to evaluate biodegradable polymer-based drug-eluting stents (DES) against durable polymer DES. The LEADERS trial was a 10-center, assessor-blind, noninferiority, "all-comers" trial (N = 1,707). All patients were centrally randomized to treatment with either biodegradable polymer biolimus-eluting stents (BES) (n = 857) or durable polymer sirolimus-eluting stents (SES) (n = 850). The primary endpoint was a composite of cardiac death, myocardial infarction (MI), or clinically indicated target vessel revascularization within 9 months. Secondary endpoints included extending the primary endpoint to 5 years and stent thrombosis (ST) (Academic Research Consortium definition). Analysis was by intention to treat. At 5 years, the BES was noninferior to SES for the primary endpoint (186 [22.3%] vs. 216 [26.1%], rate ratio [RR]: 0.83 [95% confidence interval (CI): 0.68 to 1.02], p for noninferiority <0.0001, p for superiority = 0.069). The BES was associated with a significant reduction in the more comprehensive patient-orientated composite endpoint of all-cause death, any MI, and all-cause revascularization (297 [35.1%] vs. 339 [40.4%], RR: 0.84 [95% CI: 0.71 to 0.98], p for superiority = 0.023). A significant reduction in very late definite ST from 1 to 5 years was evident with the BES (n = 5 [0.7%] vs. n = 19 [2.5%], RR: 0.26 [95% CI: 0.10 to 0.68], p = 0.003), corresponding to a significant reduction in ST-associated clinical events (primary endpoint) over the same time period (n = 3 of 749 vs. n = 14 of 738, RR: 0.20 [95% CI: 0.06 to 0.71], p = 0.005). The safety benefit of the biodegradable polymer BES, compared with the durable polymer SES, was related to a significant reduction in very late ST (>1 year) and associated composite clinical outcomes. (Limus Eluted From

  13. Rationale and design of the Patient Related OuTcomes with Endeavor versus Cypher stenting Trial (PROTECT): randomized controlled trial comparing the incidence of stent thrombosis and clinical events after sirolimus or zotarolimus drug-eluting stent implantation.

    PubMed

    Camenzind, Edoardo; Wijns, William; Mauri, Laura; Boersma, Eric; Parikh, Keyur; Kurowski, Volkhard; Gao, Runlin; Bode, Christoph; Greenwood, John P; Gershlick, Anthony; O'Neill, William; Serruys, Patrick W; Jorissen, Brenda; Steg, P Gabriel

    2009-12-01

    Drug-eluting stents (DES) reduce restenosis rates compared to bare-metal stents. Most trials using DES enrolled selected patient and lesion subtypes, and primary endpoint focused on angiographic metrics or relatively short-term outcomes. When DES are used in broader types of lesions and patients, important differences may emerge in long-term outcomes between stent types, particularly the incidence of late stent thrombosis. PROTECT is a randomized, open-label trial comparing the long-term safety of the zotarolimus-eluting stent and the sirolimus-eluting stent. The trial has enrolled 8,800 patients representative of those seen in routine clinical practice, undergoing elective, unplanned, or emergency procedures in native coronary arteries in 196 centers in 36 countries. Indications for the procedure and selection of target vessel and lesion characteristics were at the operator's discretion. Procedures could be staged, but no more than 4 target lesions could be treated per patient. Duration of dual antiplatelet therapy was prespecified to achieve similar lengths of treatment in both study arms. The shortest predefined duration was 3 months, as per the manufacturer's instructions. The primary outcome measure is the composite rate of definite and probable stent thrombosis at 3 years, centrally adjudicated using Academic Research Consortium definitions. The main secondary end points are 3-year all-cause mortality, cardiac death, large nonfatal myocardial infarction, and all myocardial infarctions. This large, international, randomized, controlled trial will provide important information on comparative rates of stent thrombosis between 2 different DES systems and safety as assessed by patient-relevant long-term clinical outcomes.

  14. Randomised comparison of drug-eluting versus bare-metal stenting in patients with non-ST elevation myocardial infarction.

    PubMed

    Remkes, Wouter S; Badings, Erik A; Hermanides, Renicus S; Rasoul, Saman; Dambrink, Jan-Henk E; Koopmans, Petra C; The, Salem Hk; Ottervanger, Jan Paul; Gosselink, A T Marcel; Hoorntje, Jan Ca; Suryapranata, Harry; van 't Hof, Arnoud Wj

    2016-01-01

    The superiority of drug-eluting stents (DES) over bare-metal stents (BMS) in patients with ST elevation myocardial infarction (STEMI) is well studied; however, randomised data in patients with non-ST elevation myocardial infarction (NSTEMI) are lacking. The objective of this study was to investigate whether stenting with everolimus-eluting stents (EES) safely reduces restenosis in patients with NSTEMI as compared to BMS. ELISA-3 patients were asked to participate in the angiographic substudy and were randomised to DE (Xience V) or BM (Vision) stenting (ELISA-3 group). The primary end point was minimal luminal diameter (MLD) at 9-month follow-up angiography. In addition, 296 patients with NSTEMI who were excluded or did not want to participate in the ELISA-3 trial (RELI group) were randomised to DE or BM stenting and underwent clinical follow-up only (major adverse cardiac events (MACE), stent thrombosis (ST)). A pooled analysis was performed to assess an effect on clinical outcome. 178 of 540 ELISA-3 patients participated in the angiographic substudy. MLD at 9 months angiography was 2.37±0.63 mm (DES) versus 1.84±0.62 mm (BMS), p<0.001. Binary restenosis occurred in 1.9% in the DES group versus 16.7% in the BMS group (RR 0.11, 95% CI 0.02 to 0.84, p=0.007). In the pooled analysis, the incidence of MACE, target vessel revascularisation and ST at 2 years follow-up in the DES versus BMS group was 12.5% versus 16.0% (p=0.28), 4.0% versus 10.4% (p=0.009) and 1.3% versus 3.0% (p=0.34), respectively. In patients with NSTEMI, use of EES is safe and decreases both angiographic and clinical restenosis as compared to BMS http://www.isrctn.com/search?q=39230163. 39230163; Post-results.

  15. Temporal course of vascular healing and neoatherosclerosis after implantation of durable- or biodegradable-polymer drug-eluting stents.

    PubMed

    Guagliumi, Giulio; Shimamura, Kunihiro; Sirbu, Vasile; Garbo, Roberto; Boccuzzi, Giacomo; Vassileva, Angelina; Valsecchi, Orazio; Fiocca, Luigi; Canova, Paolo; Colombo, Francesco; Tensol Rodriguez Pereira, Gabriel; Nakamura, Daisuke; Attizzani, Guilherme F; Cereda, Alberto; Satogami, Keisuke; De Luca, Leonardo; Saia, Francesco; Capodanno, Davide

    2018-05-19

    Delayed healing and endothelial dysfunction may occur with drug-eluting stents (DES), promoting accelerated infiltration of lipids in the neointima and development of neoatherosclerosis (NA). Pathology data suggest durable polymer (DP) of DES to play a major role in this process. Whether biodegradable polymer (BP) may address these issues is uncertain. We compared in vivo vessel healing and NA of current generation BP- or DP-DES using serial optical coherence tomography (OCT) assessments. Ninety patients with multivessel coronary artery disease were randomized 1:1 to BP everolimus-eluting stents (EES, Synergy) or DP zotarolimus-eluting stents (ZES, Resolute Integrity). Co-primary endpoints were the maximum length of uncovered struts at 3 months (powered for non-inferiority) and the percentage of patients presenting with frames of NA at 18 months (powered for superiority) as measured by OCT. The maximum length of uncovered struts at 3 months was 10 ± 8 mm in the BP-EES group and 11 ± 7 mm in the DP-ZES group (mean difference -1 mm; upper 97.5% confidence interval +2 mm; P = 0.05 for non-inferiority; P = 0.45 for superiority). The percentage of patients presenting with frames of NA at 18 months was low and similar between BP-EES and DP-ZES groups (11.6% vs. 15.9%; P = 0.56). There was no stent thrombosis in both groups at 24 months. BP-EES and DP-ZES showed a similar healing response at 3 months and a low incidence of NA at 18 months. Biocompatible polymers, regardless of whether they are durable or biodegradable, may favourably impact the long-term vascular response to current-generation DES.

  16. Tamibarotene-loaded citric acid-crosslinked alkali-treated collagen matrix as a coating material for a drug-eluting stent

    NASA Astrophysics Data System (ADS)

    Inoue, Motoki; Takayanagi, Mariko; Fujiu, Katsuhito; Manabe, Ichiro; Nagai, Ryozo; Taguchi, Tetsushi

    2012-12-01

    Tamibarotene-loaded biodegradable matrices with antithrombogenic and drug-releasing properties were prepared in a crosslinking reaction between amino groups of alkali-treated collagen (AlCol) and active ester groups of trisuccinimidyl citrate. The resulting matrices were characterized by their residual amino group concentrations, swelling ratios and thermal, antithrombogenic and drug-releasing properties. It was clarified that the addition of tamibarotene does not inhibit matrix formation. After immersion in water, the swelling ratio of a matrix became lower than that prior to immersion. Thermal analysis indicated that AlCol interacted with tamibarotene. The addition of tamibarotene to the matrix did not influence the antithrombogenic property of the resulting matrix. A matrix with a high crosslinking density had a prolonged tamibarotene elution time. These results demonstrate that tamibarotene-loaded matrices have great potential as a coating material for drug-eluting stents.

  17. Rational use of drug-eluting stents: a comparison of different policies.

    PubMed

    Remmel, Marko; Hartmann, Franz; Harland, Lars C; Schunkert, Heribert; Radke, Peter W

    2007-06-01

    Long-term results of recent landmark trials document both benefits and risks of drug-eluting stents (DES) for coronary revascularization. Interestingly, the conclusions drawn from these data vary widely since significant differences in DES penetration rates become obvious when the utilization of this technology is compared between hospitals or even countries. Based on the recommendations of the European Society of Cardiology, the FDA as well as data derived from the BASKET-LATE study, we propose that a maximum penetration rate of 50% for DES seems appropriate at present. Analysis of the length/diameter distribution combined with the use of validated restenosis reference charts allows identification of high-risk patients regarding restenosis risk and modeling the use of DES depending on financial resources and clinical indication. Such algorithm provides the rational for preprocedural risk stratification and efficient use of resources.

  18. Early Strut Coverage in Patients Receiving Drug-Eluting Stents and its Implications for Dual Antiplatelet Therapy: A Randomized Trial.

    PubMed

    Lee, Seung-Yul; Kim, Jung-Sun; Yoon, Hyuck-Jun; Hur, Seung-Ho; Lee, Sang-Gon; Kim, Jin Won; Hong, Young Joon; Kim, Ki-Seok; Choi, So-Yeon; Shin, Dong-Ho; Nam, Chung-Mo; Kim, Byeong-Keuk; Ko, Young-Guk; Choi, Donghoon; Jang, Yangsoo; Hong, Myeong-Ki

    2018-02-09

    This study sought to measure early strut coverage in patients receiving drug-eluting stents (DESs) and to explore the feasibility of short-term dual antiplatelet therapy (DAPT) based on the degree of early strut coverage. Data for early strut coverage in patients receiving new-generation DESs, and its implications for DAPT continuation were limited. A randomized, multicenter trial was conducted in 894 patients treated with DESs. Patients were randomly assigned to everolimus-eluting stent (EES) (n = 444) or biolimus-eluting stent (BES) (n = 450) groups and optical coherence tomography (OCT)-guided (n = 445) or angiography-guided (n = 449) implantation groups using a 2-by-2 factorial design. Early strut coverage was measured as the percentage of uncovered struts on 3-month follow-up OCT examination. The primary outcome was the difference in early strut coverage between EES and BES groups and between OCT- and angiography-guided implantation groups. The secondary outcome was a composite of cardiac death, myocardial infarction, stent thrombosis, and major bleeding during the first 12 months post-procedure in patients receiving 3-month DAPT based on the presence of early strut coverage (≤6% uncovered) on 3-month follow-up OCT. Three-month follow-up OCT data were acquired for 779 patients (87.1%). The median percentage of uncovered struts at 3 months was 8.9% and 8.2% in the EES and BES groups, respectively (p = 0.69) and was lower in the OCT-guided group (7.5%) than in the angiography-guided group (9.9%; p = 0.009). Favorable early strut coverage (≤6% uncovered strut) was observed in 320 of 779 patients (41.1%). At 12 months, the composite event rarely occurred in the 3-month (0.3%) or 12-month (0.2%) DAPT groups (p = 0.80). OCT-guided DES implantation improved early strut coverage compared with angiography-guided DES implantation, with no difference in strut coverage between EES and BES groups. Short-term DAPT may be feasible in selected patients with

  19. Use of drug-eluting stents versus bare-metal stents in Korea: a cost-minimization analysis using population data.

    PubMed

    Suh, Hae Sun; Song, Hyun Jin; Jang, Eun Jin; Kim, Jung-Sun; Choi, Donghoon; Lee, Sang Moo

    2013-07-01

    The goal of this study was to perform an economic analysis of a primary stenting with drug-eluting stents (DES) compared with bare-metal stents (BMS) in patients with acute myocardial infarction (AMI) admitted through an emergency room (ER) visit in Korea using population-based data. We employed a cost-minimization method using a decision analytic model with a two-year time period. Model probabilities and costs were obtained from a published systematic review and population-based data from which a retrospective database analysis of the national reimbursement database of Health Insurance Review and Assessment covering 2006 through 2010 was performed. Uncertainty was evaluated using one-way sensitivity analyses and probabilistic sensitivity analyses. Among 513 979 cases with AMI during 2007 and 2008, 24 742 cases underwent stenting procedures and 20 320 patients admitted through an ER visit with primary stenting were identified in the base model. The transition probabilities of DES-to-DES, DES-to-BMS, DES-to-coronary artery bypass graft, and DES-to-balloon were 59.7%, 0.6%, 4.3%, and 35.3%, respectively, among these patients. The average two-year costs of DES and BMS in 2011 Korean won were 11 065 528 won/person and 9 647 647 won/person, respectively. DES resulted in higher costs than BMS by 1 417 882 won/person. The model was highly sensitive to the probability and costs of having no revascularization. Primary stenting with BMS for AMI with an ER visit was shown to be a cost-saving procedure compared with DES in Korea. Caution is needed when applying this finding to patients with a higher level of severity in health status.

  20. Are Everolimus-Eluting Stents Associated With Better Clinical Outcomes Compared to Other Drug-Eluting Stents in Patients With Type 2 Diabetes Mellitus?

    PubMed Central

    Bundhun, Pravesh Kumar; Pursun, Manish; Teeluck, Abhishek Rishikesh; Long, Man-Yun

    2016-01-01

    Abstract Controversies still exist with the use of Everolimus-Eluting Stents (EES) compared to other Drug-Eluting Stents (DES) in patients with Type 2 Diabetes Mellitus (T2DM). Therefore, in order to solve this issue, we aim to compare the 1-year adverse clinical outcomes between EES and non-EE DES with a larger number of patients with T2DM. Medline, EMBASE, PubMed databases, as well as the Cochrane library were searched for randomized controlled trials (RCTs) and observational studies (OS) comparing EES and non-EE DES in patients with T2DM. One-year adverse outcomes were considered as the clinical endpoints in this study. Odd ratios (OR) with 95% confidence interval (CI) were used to express the pooled effect on discontinuous variables and the pooled analyses were performed with RevMan 5.3. Ten studies consisting of a total of 11,981 patients with T2DM (6800 patients in the EES group and 5181 in the non-EE DES group) were included in this meta-analysis. EES were associated with a significantly lower major adverse cardiac events (MACEs) with OR: 0.83, 95% CI: 0.70–0.98, P = 0.03. Revascularization including target vessel revascularization (TVR) and target lesion revascularization (TLR) were also significantly lower in the EES group with OR: 0.62, 95% CI: 0.40–0.94, P = 0.03 and OR: 0.74, 95% CI: 0.57–0.95, P = 0.02, respectively. Also, a significantly lower rate of stent thrombosis with OR: 0.63, 95% CI: 0.46–0.86, P = 0.003 was observed in the EES group. However, a similar mortality rate was reported between the EES and non-EE DES groups. During this 1-year follow-up period, EES were associated with significantly better clinical outcomes compared to non-EE DES in patients suffering from T2DM. However, further research comparing EES with non-EE DES in insulin-treated and noninsulin-treated patients with T2DM are recommended. PMID:27057888

  1. Drug-eluting stent thrombosis: results from the multicenter Spanish registry ESTROFA (Estudio ESpañol sobre TROmbosis de stents FArmacoactivos).

    PubMed

    de la Torre-Hernández, José M; Alfonso, Fernando; Hernández, Felipe; Elizaga, Jaime; Sanmartin, Marcelo; Pinar, Eduardo; Lozano, Iñigo; Vazquez, Jose M; Botas, Javier; Perez de Prado, Armando; Hernández, Jose M; Sanchis, Juan; Nodar, Juan M Ruiz; Gomez-Jaume, Alfredo; Larman, Mariano; Diarte, Jose A; Rodríguez-Collado, Javier; Rumoroso, Jose R; Lopez-Minguez, Jose R; Mauri, Josepa

    2008-03-11

    This study sought to assess the incidence, predictors, and outcome of drug-eluting stent(DES) thrombosis in real-world clinical practice. The DES thromboses in randomized trials could not be comparable to those observed in clinical practice, frequently including off-label indications. We designed a large-scale, nonindustry-linked multicentered registry, with 20 centers in Spain. The participant centers provided follow-up data for their patients treated with DES, reporting a detailed standardized form in the event of any angiography-documented DES-associated thrombosis occurring. Of 23,500 patients treated with DES, definite stent thrombosis(ST) developed in 301: 24 acute, 125 subacute, and 152 late. Of the late, 62 occurred >1 year(very late ST). The cumulative incidence was 2% at 3 years. Antiplatelet treatment had been discontinued in 95 cases(31.6%). No differences in incidences were found among stent types. Independent predictors for subacute ST analyzed in a subgroup of 14,120 cases were diabetes, renal failure, acute coronary syndrome, ST-segment elevation myocardial infarction, stent length, and left anterior descending artery stenting, and for late ST were ST-segment elevation myocardial infarction, stenting in left anterior descending artery, and stent length. Mortality at 1-year follow-up was 16% and ST recurrence 4.6%. Older age, left ventricular ejection fraction <45%, nonrestoration of Thrombolysis In Myocardial Infarction flow grade 3, and additional stenting were independent predictors for mortality. The cumulative incidence of ST after DES implantation was 2% at 3 years. No differences were found among stent types. Patient profiles differed between early and late ST. Short-term prognosis is poor, especially when restoration of normal flow fails.

  2. My Interventional Drug-Eluting Stent Educational App (MyIDEA): Patient-Centered Design Methodology

    PubMed Central

    Shroff, Adhir; Groo, Vicki; Dickens, Carolyn; Field, Jerry; Baumann, Matthew; Welland, Betty; Gutowski, Gerry; Flores Jr, Jose D; Zhao, Zhongsheng; Bahroos, Neil; Hynes, Denise M; Wilkie, Diana J

    2015-01-01

    Background Patient adherence to medication regimens is critical in most chronic disease treatment plans. This study uses a patient-centered tablet app, “My Interventional Drug-Eluting Stent Educational App (MyIDEA).” This is an educational program designed to improve patient medication adherence. Objective Our goal is to describe the design, methodology, limitations, and results of the MyIDEA tablet app. We created a mobile technology-based patient education app to improve dual antiplatelet therapy adherence in patients who underwent a percutaneous coronary intervention and received a drug-eluting stent. Methods Patient advisers were involved in the development process of MyIDEA from the initial wireframe to the final launch of the product. The program was restructured and redesigned based on the patient advisers’ suggestions as well as those from multidisciplinary team members. To accommodate those with low health literacy, we modified the language and employed attractive color schemes to improve ease of use. We assumed that the target patient population may have little to no experience with electronic tablets, and therefore, we designed the interface to be as intuitive as possible. Results The MyIDEA app has been successfully deployed to a low-health-literate elderly patient population in the hospital setting. A total of 6 patients have interacted with MyIDEA for an average of 17.6 minutes/session. Conclusions Including patient advisers in the early phases of a mobile patient education development process is critical. A number of changes in text order, language, and color schemes occurred to improve ease of use. The MyIDEA program has been successfully deployed to a low-health-literate elderly patient population. Leveraging patient advisers throughout the development process helps to ensure implementation success. PMID:26139587

  3. Stents Eluting 6-Mercaptopurine Reduce Neointima Formation and Inflammation while Enhancing Strut Coverage in Rabbits

    PubMed Central

    Ruiter, Matthijs S.; van Tiel, Claudia M.; Doornbos, Albert; Marinković, Goran; Strang, Aart C.; Attevelt, Nico J. M.; de Waard, Vivian; de Winter, Robbert J.; Steendam, Rob; de Vries, Carlie J. M.

    2015-01-01

    Background The introduction of drug-eluting stents (DES) has dramatically reduced restenosis rates compared with bare metal stents, but in-stent thrombosis remains a safety concern, necessitating prolonged dual anti-platelet therapy. The drug 6-Mercaptopurine (6-MP) has been shown to have beneficial effects in a cell-specific fashion on smooth muscle cells (SMC), endothelial cells and macrophages. We generated and analyzed a novel bioresorbable polymer coated DES, releasing 6-MP into the vessel wall, to reduce restenosis by inhibiting SMC proliferation and decreasing inflammation, without negatively affecting endothelialization of the stent surface. Methods Stents spray-coated with a bioresorbable polymer containing 0, 30 or 300 μg 6-MP were implanted in the iliac arteries of 17 male New Zealand White rabbits. Animals were euthanized for stent harvest 1 week after implantation for evaluation of cellular stent coverage and after 4 weeks for morphometric analyses of the lesions. Results Four weeks after implantation, the high dose of 6-MP attenuated restenosis with 16% compared to controls. Reduced neointima formation could at least partly be explained by an almost 2-fold induction of the cell cycle inhibiting kinase p27Kip1. Additionally, inflammation score, the quantification of RAM11-positive cells in the vessel wall, was significantly reduced in the high dose group with 23% compared to the control group. Evaluation with scanning electron microscopy showed 6-MP did not inhibit strut coverage 1 week after implantation. Conclusion We demonstrate that novel stents coated with a bioresorbable polymer coating eluting 6-MP inhibit restenosis and attenuate inflammation, while stimulating endothelial coverage. The 6-MP-eluting stents demonstrate that inhibition of restenosis without leaving uncovered metal is feasible, bringing stents without risk of late thrombosis one step closer to the patient. PMID:26389595

  4. Cost-effectiveness of drug-eluting stents versus bare-metal stents in patients undergoing percutaneous coronary intervention.

    PubMed

    Baschet, Louise; Bourguignon, Sandrine; Marque, Sébastien; Durand-Zaleski, Isabelle; Teiger, Emmanuel; Wilquin, Fanny; Levesque, Karine

    2016-01-01

    To determine the cost-effectiveness of drug-eluting stents (DES) compared with bare-metal stents (BMS) in patients requiring a percutaneous coronary intervention in France, using a recent meta-analysis including second-generation DES. A cost-effectiveness analysis was performed in the French National Health Insurance setting. Effectiveness settings were taken from a meta-analysis of 117 762 patient-years with 76 randomised trials. The main effectiveness criterion was major cardiac event-free survival. Effectiveness and costs were modelled over a 5-year horizon using a three-state Markov model. Incremental cost-effectiveness ratios and a cost-effectiveness acceptability curve were calculated for a range of thresholds for willingness to pay per year without major cardiac event gain. Deterministic and probabilistic sensitivity analyses were performed. Base case results demonstrated that DES are dominant over BMS, with an increase in event-free survival and a cost-reduction of €184, primarily due to a diminution of second revascularisations, and an absence of myocardial infarction and stent thrombosis. These results are robust for uncertainty on one-way deterministic and probabilistic sensitivity analyses. Using a cost-effectiveness threshold of €7000 per major cardiac event-free year gained, DES has a >95% probability of being cost-effective versus BMS. Following DES price decrease, new-generation DES development and taking into account recent meta-analyses results, the DES can now be considered cost-effective regardless of selective indication in France, according to European recommendations.

  5. Impact of Drug Metabolism/Pharmacokinetics and Their Relevance upon Taxus-based Drug Development.

    PubMed

    Hao, Da-Cheng; Ge, Guang-Bo; Wang, Ping; Yang, Ling

    2018-05-22

    Drug metabolism and pharmacokinetic (DMPK) studies of Taxus natural products, their semi-synthetic derivatives and analogs are indispensable in the optimization of lead compounds and clinical therapy. These studies can lead to development of new drug entities with improved absorption, distribution, metabolism, excretion and toxicity (ADME/T) profiles. To date, there have been no comprehensive reviews of the DMPK features of Taxus derived medicinal compounds.Natural and semi-synthetic taxanes may cause and could be affected by drug-drug interaction (DDI). Hence ADME/T studies of various taxane-containing formulations are important; to date these studies indicate that the role of cytochrome p450s and drug transporters is more prominent than phase II drug metabolizing enzymes. Mechanisms of taxane DMPK mediated by nuclear receptors, microRNAs, and single nucleotide polymorphisms are being revealed. Herein we review the latest knowledge on these topics, as well as the gaps in knowledge of the DMPK issues of Taxus compounds. DDIs significantly impact the PK/pharmacodynamics performance of taxanes and co-administered chemicals, which may inspire researchers to develop novel formula. While the ADME/T profiles of some taxanes are well defined, DMPK studies should be extended to more Taxus compounds, species, and Taxus -involved formulations, which would be streamlined by versatile omics platforms and computational analyses. Further biopharmaceutical investigations will be beneficial tothe translation of bench findings to the clinical applications. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  6. Stent coverage and neointimal proliferation in bare metal stents postdilated with a Paclitaxel-eluting balloon versus everolimus-eluting stents: prospective randomized study using optical coherence tomography at 6-month follow-up.

    PubMed

    Poerner, Tudor C; Otto, Sylvia; Gassdorf, Johannes; Nitsche, Kristina; Janiak, Florian; Scheller, Bruno; Goebel, Björn; Jung, Christian; Figulla, Hans R

    2014-12-01

    In this randomized trial, strut coverage and neointimal proliferation of a therapy of bare metal stents (BMSs) postdilated with the paclitaxel drug-eluting balloon (DEB) was compared with everolimus drug-eluting stents (DESs) at 6-month follow-up using optical coherence tomography. We hypothesized sufficient stent coverage at follow-up. A total of 105 lesions in 90 patients were treated with either XIENCE V DES (n=51) or BMS postdilated with the SeQuent Please DEB (n=54). At follow-up, comparable results on the primary optical coherence tomography end point (percentage uncovered struts 5.64±9.65% in BMS+DEB versus 4.93±9.29% in DES; P=0.366) were found. Thus, BMS+DEB achieved the prespecified noninferiority margin of 5% uncovered struts versus DES (difference between treatment means, 0.71%; one-sided upper 95% confidence interval, 4.14%; noninferiority P=0.04). Optical coherence tomography analysis showed significantly more global neointimal proliferation in the BMS+DEB group (15.7±7.8 versus 11.0±5.2 mm(3) proliferation volume/cm stent length; P=0.002). No significant focal in-stent stenosis analyzed with angiography (percentage diameter stenosis at follow-up, 22.8±11.9 versus 16.9±10.4; P=0.014) and optical coherence tomography (peak local area stenosis, 39.5±13.8% versus 36.8±15.6%; P=0.409) was found. Good stent strut coverage of >94% was found in both therapy groups. Despite greater suppression of global neointimal growth in DES, both DES and BMS+DEB effectively prevented clinically relevant focal restenosis at 6-month follow-up. http://www.clinicaltrials.gov. Unique identifier: NCT01056744. © 2014 American Heart Association, Inc.

  7. Everolimus-Eluting Stents or Bypass Surgery for Left Main Coronary Artery Disease.

    PubMed

    Stone, Gregg W; Sabik, Joseph F; Serruys, Patrick W; Simonton, Charles A; Généreux, Philippe; Puskas, John; Kandzari, David E; Morice, Marie-Claude; Lembo, Nicholas; Brown, W Morris; Taggart, David P; Banning, Adrian; Merkely, Béla; Horkay, Ferenc; Boonstra, Piet W; van Boven, Ad J; Ungi, Imre; Bogáts, Gabor; Mansour, Samer; Noiseux, Nicolas; Sabaté, Manel; Pomar, José; Hickey, Mark; Gershlick, Anthony; Buszman, Pawel; Bochenek, Andrzej; Schampaert, Erick; Pagé, Pierre; Dressler, Ovidiu; Kosmidou, Ioanna; Mehran, Roxana; Pocock, Stuart J; Kappetein, A Pieter

    2016-12-08

    Patients with obstructive left main coronary artery disease are usually treated with coronary-artery bypass grafting (CABG). Randomized trials have suggested that drug-eluting stents may be an acceptable alternative to CABG in selected patients with left main coronary disease. We randomly assigned 1905 eligible patients with left main coronary artery disease of low or intermediate anatomical complexity to undergo either percutaneous coronary intervention (PCI) with fluoropolymer-based cobalt-chromium everolimus-eluting stents (PCI group, 948 patients) or CABG (CABG group, 957 patients). Anatomic complexity was assessed at the sites and defined by a Synergy between Percutaneous Coronary Intervention with Taxus and Cardiac Surgery (SYNTAX) score of 32 or lower (the SYNTAX score reflects a comprehensive angiographic assessment of the coronary vasculature, with 0 as the lowest score and higher scores [no upper limit] indicating more complex coronary anatomy). The primary end point was the rate of a composite of death from any cause, stroke, or myocardial infarction at 3 years, and the trial was powered for noninferiority testing of the primary end point (noninferiority margin, 4.2 percentage points). Major secondary end points included the rate of a composite of death from any cause, stroke, or myocardial infarction at 30 days and the rate of a composite of death, stroke, myocardial infarction, or ischemia-driven revascularization at 3 years. Event rates were based on Kaplan-Meier estimates in time-to-first-event analyses. At 3 years, a primary end-point event had occurred in 15.4% of the patients in the PCI group and in 14.7% of the patients in the CABG group (difference, 0.7 percentage points; upper 97.5% confidence limit, 4.0 percentage points; P=0.02 for noninferiority; hazard ratio, 1.00; 95% confidence interval, 0.79 to 1.26; P=0.98 for superiority). The secondary end-point event of death, stroke, or myocardial infarction at 30 days occurred in 4.9% of the

  8. DMSO inhibits human platelet activation through cyclooxygenase-1 inhibition. A novel agent for drug eluting stents?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Asmis, Lars; Tanner, Felix C.; Center for Integrative Human Physiology, University of Zuerich, Zuerich

    2010-01-22

    Background: DMSO is routinely infused together with hematopoietic cells in patients undergoing myeloablative therapy and was recently found to inhibit smooth muscle cells proliferation and arterial thrombus formation in the mouse by preventing tissue factor (TF), a key activator of the coagulation cascade. This study was designed to investigate whether DMSO prevents platelet activation and thus, whether it may represent an interesting agent to be used on drug eluting stents. Methods and results: Human venous blood from healthy volunteers was collected in citrated tubes and platelet activation was studied by cone and platelet analyzer (CPA) and rapid-platelet-function-assay (RPFA). CPA analysismore » showed that DMSO-treated platelets exhibit a lower adherence in response to shear stress (-15.54 {+-} 0.9427%, n = 5, P < 0.0001 versus control). Additionally, aggregometry studies revealed that DMSO-treated, arachidonate-stimulated platelets had an increased lag phase (18.0% {+-} 4.031, n = 9, P = 0.0004 versus control) as well as a decreased maximal aggregation (-6.388 {+-} 2.212%, n = 6, P = 0.0162 versus control). Inhibitory action of DMSO could be rescued by exogenous thromboxane A2 and was mediated, at least in part, by COX-1 inhibition. Conclusions: Clinically relevant concentrations of DMSO impair platelet activation by a thromboxane A2-dependent, COX-1-mediated effect. This finding may be crucial for the previously reported anti-thrombotic property displayed by DMSO. Our findings support a role for DMSO as a novel drug to prevent not only proliferation, but also thrombotic complications of drug eluting stents.« less

  9. Impact of polymer formulations on neointimal proliferation after zotarolimus-eluting stent with different polymers: insights from the RESOLUTE trial.

    PubMed

    Waseda, Katsuhisa; Ako, Junya; Yamasaki, Masao; Koizumi, Tomomi; Sakurai, Ryota; Hongo, Yoichiro; Koo, Bon-Kwon; Ormiston, John; Worthley, Stephen G; Whitbourn, Robert J; Walters, Darren L; Meredith, Ian T; Fitzgerald, Peter J; Honda, Yasuhiro

    2011-06-01

    Polymer formulation may affect the efficacy of drug-eluting stents. Resolute, Endeavor, and ZoMaxx are zotarolimus-eluting stents with different stent platforms and different polymer coatings and have been tested in clinical trials. The aim of this analysis was to compare the efficacy of zotarolimus-eluting stents with different polymers. Data were obtained from the first-in man trial or first randomized trials of each stent, The Clinical RESpOnse EvaLUation of the MedTronic Endeavor CR ABT-578 Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions (RESOLUTE), Randomized Controlled Trial to Evaluate the Safety and Efficacy of the Medtronic AVE ABT-578 Eluting Driver Coronary Stent in De Novo Native Coronary Artery Lesions (ENDEAVOR II), and ZoMaxx I trials. Follow-up intravascular ultrasound analyses (8 to 9 months of follow-up) were possible in 353 patients (Resolute: 88, Endeavor: 98, ZoMaxx: 82, Driver: 85). Volume index (volume/stent length) was obtained for vessel, stent, lumen, peristent plaque, and neointima. Cross-sectional narrowing was defined as neointimal area divided by stent area (%). Neointima-free frame ratio was calculated as the number of frames without intravascular ultrasound-detectable neointima divided by the total number of frames within the stent. At baseline, vessel, lumen, and peristent plaque volume index were not significantly different among the 4 stent groups. At follow-up, percent neointimal obstruction was significantly lower in Resolute compared with Endeavor, ZoMaxx, and Driver (Resolute: 3.7±4.0, Endeavor: 17.5±10.1, ZoMaxx: 14.6±8.1, Driver: 29.4±17.2%; P<0.001). Greater maximum cross-sectional narrowing and higher neointima-free frame ratio, suggesting less neointimal coverage, were observed in Resolute compared with other stent groups. Multiple regression analysis confirmed that the biodurable polymer used in Resolute independently correlated with neointimal suppression among 3 zotarolimus-eluting stents

  10. Pulmonary vein stenosis with collateralization via esophageal varices: Long-term follow-up after successful treatment with drug-eluting stent.

    PubMed

    Goldberg, Jason F; Jensen, Craig L; Krishnamurthy, Rajesh; Varghese, Nidhy P; Justino, Henri

    2018-01-01

    We describe the long-term follow-up of a child with recurrent hemoptysis due to severe pulmonary vein stenosis decompressing via collaterals to esophageal varices. Case report SETTING: Tertiary children's hospital PATIENT: Single child through ages 2- to 11-year old INTERVENTIONS: The child underwent cutting balloon angioplasty, bare metal stenting, and implantation of a PTFE-covered stent, all of which failed rapidly. Only after placement of a paclitaxel drug eluting stent did he have prolonged relief from hemoptysis and long-term patency of the treated vein. The stents were serially dilated to keep up with somatic growth of the child, eventually culminating in the need to induce intentional stent fracture. We highlight novel transcatheter techniques to treat this vexing condition, discuss mechanisms of disease treatment and progression, and present the only patient with this rare combination of lesions to have achieved both longstanding pulmonary vein patency and resolution of esophageal varices. © 2017 Wiley Periodicals, Inc.

  11. Inverse Relationship between Serum VEGF Levels and Late In-Stent Restenosis of Drug-Eluting Stents

    PubMed Central

    Shen, Li; Ji, Meng; Cai, Sishi; Chen, Jiahui; Yao, Zhifeng

    2017-01-01

    Late in-stent restenosis (ISR) has raised concerns regarding the long-term efficacy of drug-eluting stents (DES). The role of vascular endothelial growth factor (VEGF) in the pathological process of ISR is controversial. This retrospective study aimed to investigate the relationship between serum VEGF levels and late ISR in patients with DES implantation. A total of 158 patients who underwent angiography follow-up beyond 1 year after intervention were included. The study population was classified into ISR and non-ISR groups. The ISR group was further divided according to follow-up duration and Mehran classification. VEGF levels were significantly lower in the ISR group than in the non-ISR group [96.34 (48.18, 174.14) versus 179.14 (93.59, 307.74) pg/mL, p < 0.0001]. Multivariate regression revealed that VEGF level, procedure age, and low-density lipoprotein cholesterol were independent risk factors for late ISR formation. Subgroup analysis demonstrated that VEGF levels were even lower in the very late (≥5 years) and diffuse ISR group (Mehran patterns II, III, and IV) than in the late ISR group (1–4 years) and the focal ISR group (Mehran pattern I), respectively. Furthermore, significant difference was found between diffuse and focal ISR groups. Serum VEGF levels were inversely associated with late ISR after DES implantation. PMID:28373989

  12. Long-term results of a sirolimus-eluting stent with biodegradable polymer (RAPSTROM™) in de novo coronary stenoses.

    PubMed

    Figini, Filippo; Manjunath, Chaman Nadish; Srinivas, Balaji Chandra; Sadananda, Kanvar Sarat; Sreedharan, Madhu; Fischer, Louie; Pillai, Ramakrishna; Varghese, Kiron; Gopal, Ajay K; Nagesh, Chamarajnagar Mahadevappa; Sheiban, Imad

    2017-10-07

    To report long-term results of a novel sirolimus-eluting stent with biodegradable polymer BACKGROUND: Newer generation drug-eluting stents are characterized by thin struts, improved platform design and highly biocompatible polymer carrying the antiproliferative drug. The RapstromTM stent, sharing these features, showed promising outcomes in preclinical models and in a first-in-man trial. The present study is a multicenter, non-randomized post-market registry, including patients with de novo coronary artery disease treated with implantation of one or more Rapstrom stents. Primary endpoint of the study was the rate of major adverse cardiac events (MACE) at three-year follow-up. 1073 patients were enrolled, with a high prevalence of diabetes (35%) and acute coronary syndrome at presentation (82%); at three-year follow up, MACE rate was 14.8%, with a low incidence of definite or probable stent thrombosis (0.75%). These data confirm the good clinical performance of the Rapstrom stent, supporting the concept that the combination of thin struts and biodegradable polymer is associated with positive clinical outcomes. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Randomised comparison of drug-eluting versus bare-metal stenting in patients with non-ST elevation myocardial infarction

    PubMed Central

    Remkes, Wouter S; Badings, Erik A; Hermanides, Renicus S; Rasoul, Saman; Dambrink, Jan-Henk E; Koopmans, Petra C; The, Salem HK; Ottervanger, Jan Paul; Gosselink, A T Marcel; Hoorntje, Jan CA; Suryapranata, Harry; van 't Hof, Arnoud WJ

    2016-01-01

    Objective The superiority of drug-eluting stents (DES) over bare-metal stents (BMS) in patients with ST elevation myocardial infarction (STEMI) is well studied; however, randomised data in patients with non-ST elevation myocardial infarction (NSTEMI) are lacking. The objective of this study was to investigate whether stenting with everolimus-eluting stents (EES) safely reduces restenosis in patients with NSTEMI as compared to BMS. Methods ELISA-3 patients were asked to participate in the angiographic substudy and were randomised to DE (Xience V) or BM (Vision) stenting (ELISA-3 group). The primary end point was minimal luminal diameter (MLD) at 9-month follow-up angiography. In addition, 296 patients with NSTEMI who were excluded or did not want to participate in the ELISA-3 trial (RELI group) were randomised to DE or BM stenting and underwent clinical follow-up only (major adverse cardiac events (MACE), stent thrombosis (ST)). A pooled analysis was performed to assess an effect on clinical outcome. Results 178 of 540 ELISA-3 patients participated in the angiographic substudy. MLD at 9 months angiography was 2.37±0.63 mm (DES) versus 1.84±0.62 mm (BMS), p<0.001. Binary restenosis occurred in 1.9% in the DES group versus 16.7% in the BMS group (RR 0.11, 95% CI 0.02 to 0.84, p=0.007). In the pooled analysis, the incidence of MACE, target vessel revascularisation and ST at 2 years follow-up in the DES versus BMS group was 12.5% versus 16.0% (p=0.28), 4.0% versus 10.4% (p=0.009) and 1.3% versus 3.0% (p=0.34), respectively. Conclusions In patients with NSTEMI, use of EES is safe and decreases both angiographic and clinical restenosis as compared to BMS http://www.isrctn.com/search?q=39230163. Trial registration number 39230163; Post-results. PMID:27933192

  14. Very late outcomes of drug-eluting stents coated with biodegradable polymers: insights from the 5-year follow-up of the randomized PAINT trial

    PubMed Central

    Marchini, Julio F.; Gomes, Wilton F.; Moulin, Bruno; Perin, Marco A.; Oliveira, Ludmilla A.R.R.; Arruda, J. Airton; Lima, Valter C.; Lima, Antonio A.G.; Caramori, Paulo R.A.; Medeiros, Cesar R.; Barbosa, Mauricio R.; Brito, Fabio S.; Ribeiro, Expedito E.

    2014-01-01

    Background Few studies have examined the very long-term outcomes after implantation of drug-eluting stents (DES) coated with biodegradable polymers (BP). This report presents the 5-year clinical follow-up of patients treated with BP-DES in the randomized PAINT trial. Methods The PAINT study is a prospective, multicenter randomized controlled trial that allocated 274 patients for treatment with two BP-DES formulations [paclitaxel-eluting stents (PES) or sirolimus-eluting stents (SES)] or bare metal stents (BMS) in a 1:2:2 ratio, respectively. The primary end-point of this sub-study was defined as the composite of the major cardiac adverse events (MACE) cardiac death, myocardial infarction (MI) or ischemia-driven target vessel revascularization (TVR) at 5 years. Results The 5-year MACE rates were different among the groups: 35.3%, 22.5% and 16.9% for BMS, PES and SES, respectively (P<0.05 for both DES vs. bare stent comparisons). The primary end-point was mainly driven by TVR: 31.8%, 14.1% and 12.2% for bare stents, PES and SES, respectively (P<0.05 for both DES vs. bare stent comparisons). The incidence of stent thrombosis (ST) was null for BMS during the entire follow-up. There was no definite or probable ST in the SES group after the second year, while one patient (1.0%) presented with a definite ST episode in the PES group between 4 and 5 years. Conclusions The tested biodegradable-polymer coated stents releasing either paclitaxel or sirolimus, compared with same bare metal platform, sustained their effectiveness in reducing combined major adverse cardiac events and re-intervention without an increase in ST during 5 years of follow-up. PMID:25610805

  15. Ultra-hydrophilic stent platforms promote early vascular healing and minimise late tissue response: a potential alternative to second-generation drug-eluting stents.

    PubMed

    Kolandaivelu, Kumaran; Bailey, Lynn; Buzzi, Stefano; Zucker, Arik; Milleret, Vincent; Ziogas, Algirdas; Ehrbar, Martin; Khattab, Ahmed A; Stanley, James R L; Wong, Gee K; Zani, Brett; Markham, Peter M; Tzafriri, Abraham R; Bhatt, Deepak L; Edelman, Elazer R

    2017-04-20

    Simple surface modifications can enhance coronary stent performance. Ultra-hydrophilic surface (UHS) treatment of contemporary bare metal stents (BMS) was assessed in vivo to verify whether such stents can provide long-term efficacy comparable to second-generation drug-eluting stents (DES) while promoting healing comparably to BMS. UHS-treated BMS, untreated BMS and corresponding DES were tested for three commercial platforms. A thirty-day and a 90-day porcine coronary model were used to characterise late tissue response. Three-day porcine coronary and seven-day rabbit iliac models were used for early healing assessment. In porcine coronary arteries, hydrophilic treatment reduced intimal hyperplasia relative to the BMS and corresponding DES platforms (1.5-fold to threefold reduction in 30-day angiographic and histological stenosis; p<0.04). Endothelialisation was similar on UHS-treated BMS and untreated BMS, both in swine and rabbit models, and lower on DES. Elevation in thrombotic indices was infrequent (never observed with UHS, rare with BMS, most often with DES), but, when present, correlated with reduced endothelialisation (p<0.01). Ultra-hydrophilic surface treatment of contemporary stents conferred good healing while moderating neointimal and thrombotic responses. Such surfaces may offer safe alternatives to DES, particularly when rapid healing and short dual antiplatelet therapy (DAPT) are crucial.

  16. Safety of six-month dual antiplatelet therapy after second-generation drug-eluting stent implantation: OPTIMA-C Randomised Clinical Trial and OCT Substudy.

    PubMed

    Lee, Byoung-Kwon; Kim, Jung-Sun; Lee, Oh-Huyn; Min, Pil-Ki; Yoon, Young-Won; Hong, Bum-Kee; Shin, Dong-Ho; Kang, Tae-Soo; Kim, Byung Ok; Cho, Duk-Kyu; Jeon, Dong Woon; Woo, Sung-Ill; Choi, Seonghoon; Kim, Yong Hoon; Kang, Woong-Chol; Kim, Seunghwan; Kim, Byeong-Keuk; Hong, Myeong-Ki; Jang, Yangsoo; Kwon, Hyuck Moon

    2018-03-20

    There are few randomised studies concerning the optimal duration of dual antiplatelet therapy (DAPT) for patients who receive a second-generation drug-eluting stent (DES). This trial aimed to investigate the safety of six-month compared with 12-month DAPT maintenance after second-generation DES implantation. A prospective, randomised, multicentre trial was performed at 10 medical centres. The 1,368 patients included in the study received a biolimus-eluting stent (BES) or a zotarolimus-eluting stent (ZES). The primary outcome measured was the composite of major adverse cardiac events (MACE), including cardiac death, myocardial infarction (MI), or ischaemia-driven target lesion revascularisation at the 12-month follow-up. The secondary outcome was the percentage of uncovered struts at six months in 60 patients (30 ZES, 30 BES) using optical coherence tomography (OCT) assessment. Each patient was randomly assigned to six-month (n=684) or 12-month DAPT (n=684). Major adverse cardiac events at 12 months occurred in eight patients (1.2%) in the six-month DAPT group and in four patients (0.6%) in the 12-month DAPT group (risk difference 0.6%; 95% confidence interval [CI]: -0.4-1.6%; p=0.24). The upper 95% CI limit was lower than the pre-specified limit of 4% non-inferiority (p for non-inferiority <0.05). The percentage of uncovered struts was 3.16±4.30% at six months in 60 stents of 60 patients. After second-generation DES implantation, six-month DAPT was not inferior to 12-month DAPT in terms of MACE occurrence over the 12-month follow-up period. OCT examination revealed favourable stent strut coverage at six months after stent implantation.

  17. Comparison between Exclusive and Selective Drug-Eluting Stent Strategies in Treating Patients with Multivessel Coronary Artery Disease.

    PubMed

    Tung, Ying-Chang; Hsiao, Ping-Gune; Hsu, Lung-An; Kuo, Chi-Tai; Chang, Chi-Jen

    2014-05-01

    The expanded usage of drug-eluting stents (DES) in treating patients with multivessel coronary artery disease (CAD) may sometimes be limited in real-world practice due to cost concerns. We compared the clinical outcomes of exclusive and selective DES use in treating patients with multivessel CAD. From November 2004 to December 2011, 110 patients with multivessel CAD who received four or more stents were enrolled into this study, and divided into two groups according to the DES strategy employed: exclusive DES (n = 52), or selective DES (n = 58). In the selective DES group, DES was reserved for complex lesions only, such that the incidence and predictors of clinical events were assessed. At a mean follow-up of 41.4 ± 26.5 months, there were no significant differences between the two strategies in terms of baseline characteristics, all-cause mortality (exclusive vs. selective: 1.9% vs. 6.9%, p = 0.21), cardiac death (1.9% vs. 1.7%, p = 0.94) and nonfatal myocardial infarction (3.8% vs. 5.2%, p = 0.74). Despite the presence of more ostial lesions in the exclusive DES group, there was a trend such that major adverse cardiac events (MACE) and target lesion revascularization (TLR) rates were higher in the selective DES group (MACE: 17.3% vs. 31%, p = 0.16; TLR: 11.5% vs. 24.1%, p = 0.08). The higher MACE rate in the selective DES group was mainly driven by a higher target vessel revascularization (TVR) rate (15.4% vs. 29.3%, p = 0.08). In the exclusive DES group, SYNTAX score was an independent predictor of MACE [Haxard ratio (HR): 1.09, 95% confidence internal (CI): 1.02-1.16, p = 0.01] and TVR (HR 1.08, 95% CI 1.01-1.15, p = 0.04). Compared to the exclusive DES strategy, the selective DES strategy with reservation of DES for complex lesions is associated with numerically higher, but not statistically significant, rates of MACE and all-cause mortality in this small group of patients with multivessel CAD receiving four or more stents. Bare metal stent; Drug-eluting

  18. IVUS Findings in Late and Very Late Stent Thrombosis. A Comparison Between Bare-metal and Drug-eluting Stents.

    PubMed

    Fuentes, Lara; Gómez-Lara, Josep; Salvatella, Neus; Gonzalo, Nieves; Hernández-Hernández, Felipe; Fernández-Nofrerias, Eduard; Sánchez-Recalde, Ángel; Alfonso, Fernando; Romaguera, Rafael; Ferreiro, José Luis; Roura, Gerard; Teruel, Luis; Gracida, Montserrat; Marcano, Ana Lucrecia; Gómez-Hospital, Joan-Antoni; Cequier, Ángel

    2018-05-01

    Stent thrombosis (ST) is a life-threatening complication after stent implantation. Intravascular ultrasound is able to discern most causes of ST. The aim of this study was to compare intravascular ultrasound findings between bare-metal stents (BMS) and drug-eluting stents (DES) in patients with late (31 days to 1 year) or very late ST (> 1 year). Of 250 consecutive patients with late or very late ST in 7 Spanish institutions, 114 patients (45.5% BMS and 54.5% DES) were imaged with intravascular ultrasound. Off-line intravascular ultrasound analysis was performed to assess malapposition, underexpansion, and neoatherosclerosis. The median time from stent implantation to ST was 4.0 years with BMS and 3.4 years with DES (P = .04). Isolated malapposition was similarly observed in both groups (36.5% vs 46.8%; P = .18) but was numerically lower with BMS (26.6% vs 48.0%; P = .07) in patients with very late ST. Isolated underexpansion was similarly observed in both groups (13.5% vs 11.3%; P = .47). Isolated neoatherosclerosis occurred only in patients with very late ST and was more prevalent with BMS (22.9%) than with DES (6.0%); P = .02. At 2.9 years' follow-up, there were 0% and 6.9% cardiac deaths, respectively (P = .06) and recurrent ST occurred in 4.0% and 5.2% of patients, respectively (P = .60). Malapposition was the most common finding in patients with late and very late ST and is more prevalent with DES in very late ST. In contrast, neoatherosclerosis was exclusively observed in patients with very late ST and mainly with BMS. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  19. Analytical modeling of drug dynamics induced by eluting stents in the coronary multi-layered curved domain.

    PubMed

    d'Errico, Michele; Sammarco, Paolo; Vairo, Giuseppe

    2015-09-01

    Pharmacokinetics induced by drug eluting stents (DES) in coronary walls is modeled by means of a one-dimensional multi-layered model, accounting for vessel curvature and non-homogeneous properties of the arterial tissues. The model includes diffusion mechanisms, advection effects related to plasma filtration through the walls, and bio-chemical drug reactions. A non-classical Sturm-Liouville problem with discontinuous coefficients is derived, whose closed-form analytical solution is obtained via an eigenfunction expansion. Soundness and consistency of the proposed approach are shown by numerical computations based on possible clinical treatments involving both hydrophilic and hydrophobic drugs. The influence of the main model parameters on drug delivery mechanisms is analyzed, highlighting the effects induced by vessel curvature and yielding comparative indications and useful insights into the concurring mechanisms governing the pharmacokinetics. Copyright © 2015. Published by Elsevier Inc.

  20. Direct comparison of coronary bare metal vs. drug-eluting stents: same platform, different mechanics?

    PubMed

    Schmidt, Wolfram; Lanzer, Peter; Behrens, Peter; Brandt-Wunderlich, Christoph; Öner, Alper; Ince, Hüseyin; Schmitz, Klaus-Peter; Grabow, Niels

    2018-01-08

    Drug-eluting stents (DES) compared to bare metal stents (BMS) have shown superior clinical performance, but are considered less suitable in complex cases. Most studies do not distinguish between DES and BMS with respect to their mechanical performance. The objective was to obtain mechanical parameters for direct comparison of BMS and DES. In vitro bench tests evaluated crimped stent profiles, crossability in stenosis models, elastic recoil, bending stiffness (crimped and expanded), and scaffolding properties. The study included five pairs of BMS and DES each with the same stent platforms (all n = 5; PRO-Kinetic Energy, Orsiro: BIOTRONIK AG, Bülach, Switzerland; MULTI-LINK 8, XIENCE Xpedition: Abbott Vascular, Temecula, CA; REBEL Monorail, Promus PREMIER, Boston Scientific, Marlborough, MA; Integrity, Resolute Integrity, Medtronic, Minneapolis, MN; Kaname, Ultimaster: Terumo Corporation, Tokyo, Japan). Statistical analysis used pooled variance t tests for pairwise comparison of BMS with DES. Crimped profiles in BMS groups ranged from 0.97 ± 0.01 mm (PRO-Kinetic Energy) to 1.13 ± 0.01 mm (Kaname) and in DES groups from 1.02 ± 0.01 mm (Orsiro) to 1.13 ± 0.01 mm (Ultimaster). Crossability was best for low profile stent systems. Elastic recoil ranged from 4.07 ± 0.22% (Orsiro) to 5.87 ± 0.54% (REBEL Monorail) including both BMS and DES. The bending stiffness of crimped and expanded stents showed no systematic differences between BMS and DES neither did the scaffolding. Based on in vitro measurements BMS appear superior to DES in some aspects of mechanical performance, yet the differences are small and not class uniform. The data provide assistance in selecting the optimal system for treatment and assessment of new generations of bioresorbable scaffolds. not applicable.

  1. Culotte stenting for coronary bifurcation lesions with 2nd and 3rd generation everolimus-eluting stents: the CELTIC Bifurcation Study.

    PubMed

    Walsh, Simon J; Hanratty, Colm G; Watkins, Stuart; Oldroyd, Keith G; Mulvihill, Niall T; Hensey, Mark; Chase, Alex; Smith, Dave; Cruden, Nick; Spratt, James C; Mylotte, Darren; Johnson, Tom; Hill, Jonathan; Hussein, Hafiz M; Bogaerts, Kris; Morice, Marie-Claude; Foley, David P

    2018-05-24

    The aim of this study was to provide contemporary outcome data for patients with de novo coronary disease and Medina 1,1,1 lesions who were treated with a culotte two-stent technique, and to compare the performance of two modern-generation drug-eluting stent (DES) platforms, the 3-connector XIENCE and the 2-connector SYNERGY. Patients with Medina 1,1,1 bifurcation lesions who had disease that was amenable to culotte stenting were randomised 1:1 to treatment with XIENCE or SYNERGY DES. A total of 170 patients were included. Technical success and final kissing balloon inflation occurred in >96% of cases. Major adverse cardiovascular or cerebrovascular events (MACCE: a composite of death, myocardial infarction [MI], cerebrovascular accident [CVA] and target vessel revascularisation [TVR]) occurred in 5.9% of patients by nine months. The primary endpoint was a composite of death, MI, CVA, target vessel failure (TVF), stent thrombosis and binary angiographic restenosis. At nine months, the primary endpoint occurred in 19% of XIENCE patients and 16% of SYNERGY patients (p=0.003 for non-inferiority for platform performance). MACCE rates for culotte stenting using contemporary everolimus-eluting DES are low at nine months. The XIENCE and SYNERGY stents demonstrated comparable performance for the primary endpoint.

  2. Comparison of newer-generation drug-eluting with bare-metal stents in patients with acute ST-segment elevation myocardial infarction: a pooled analysis of the EXAMINATION (clinical Evaluation of the Xience-V stent in Acute Myocardial INfArcTION) and COMFORTABLE-AMI (Comparison of Biolimus Eluted From an Erodible Stent Coating With Bare Metal Stents in Acute ST-Elevation Myocardial Infarction) trials.

    PubMed

    Sabaté, Manel; Räber, Lorenz; Heg, Dik; Brugaletta, Salvatore; Kelbaek, Henning; Cequier, Angel; Ostojic, Miodrag; Iñiguez, Andrés; Tüller, David; Serra, Antonio; Baumbach, Andreas; von Birgelen, Clemens; Hernandez-Antolin, Rosana; Roffi, Marco; Mainar, Vicente; Valgimigli, Marco; Serruys, Patrick W; Jüni, Peter; Windecker, Stephan

    2014-01-01

    This study sought to study the efficacy and safety of newer-generation drug-eluting stents (DES) compared with bare-metal stents (BMS) in an appropriately powered population of patients with ST-segment elevation myocardial infarction (STEMI). Among patients with STEMI, early generation DES improved efficacy but not safety compared with BMS. Newer-generation DES, everolimus-eluting stents, and biolimus A9-eluting stents, have been shown to improve clinical outcomes compared with early generation DES. Individual patient data for 2,665 STEMI patients enrolled in 2 large-scale randomized clinical trials comparing newer-generation DES with BMS were pooled: 1,326 patients received a newer-generation DES (everolimus-eluting stent or biolimus A9-eluting stent), whereas the remaining 1,329 patients received a BMS. Random-effects models were used to assess differences between the 2 groups for the device-oriented composite endpoint of cardiac death, target-vessel reinfarction, and target-lesion revascularization and the patient-oriented composite endpoint of all-cause death, any infarction, and any revascularization at 1 year. Newer-generation DES substantially reduce the risk of the device-oriented composite endpoint compared with BMS at 1 year (relative risk [RR]: 0.58; 95% confidence interval [CI]: 0.43 to 0.79; p = 0.0004). Similarly, the risk of the patient-oriented composite endpoint was lower with newer-generation DES than BMS (RR: 0.78; 95% CI: 0.63 to 0.96; p = 0.02). Differences in favor of newer-generation DES were driven by both a lower risk of repeat revascularization of the target lesion (RR: 0.33; 95% CI: 0.20 to 0.52; p < 0.0001) and a lower risk of target-vessel infarction (RR: 0.36; 95% CI: 0.14 to 0.92; p = 0.03). Newer-generation DES also reduced the risk of definite stent thrombosis (RR: 0.35; 95% CI: 0.16 to 0.75; p = 0.006) compared with BMS. Among patients with STEMI, newer-generation DES improve safety and efficacy compared with BMS throughout 1 year

  3. In vivo evaluation of axial integrity of coronary stents using intravascular ultrasound: Insights on longitudinal stent deformation.

    PubMed

    Dvir, Danny; Kitabata, Hironori; Barbash, Israel M; Minha, Sa'ar; Badr, Salem; Loh, Joshua P; Chen, Fang; Torguson, Rebecca; Waksman, Ron

    2014-09-01

    To evaluate the axial integrity of different coronary stents using intravascular ultrasound (IVUS). Longitudinal stent deformation was recently reported. Consecutive patients who underwent IVUS analysis after drug-eluting stent (DES) implantation for de novo coronary lesions were evaluated. Stent length was compared with label length for calculation of absolute change and relative difference (absolute change divided by label length). A total of 233 DES utilizing five different platforms were included. The median absolute change in stent length was 0.90 mm (interquartile range [IQR] 0.48-1.39) and the relative difference was 5.24% (IQR 2.55-8.29). There was no significant difference among the groups in median absolute or relative change: Cypher 0.89 mm/3.89%, Taxus 0.88 mm/5.39%, Endeavor 1.16 mm/6.77%, Xience V 0.86 mm/5.80%, and PROMUS Element 0.79 mm/5.34% (P = 0.085, P = 0.072, respectively). Multivariate logistic regression revealed that the Cypher stent was independently correlated with a lower change in length, whereas stent label length and deployment pressure were correlated with higher absolute change. The axial integrity of DES platforms examined in vivo was high, with only mild changes in stent length after implantation. While there are differences between first- and second-generation DES, axial integrity among second-generation DES was similar. © 2013 Wiley Periodicals, Inc.

  4. Drug eluting balloons for de novo coronary lesions – a systematic review and meta-analysis

    PubMed Central

    2013-01-01

    Background The role of drug-eluting balloons (DEB) is unclear. Increasing evidence has shown a benefit for the treatment of in-stent restenosis. Its effect on de novo coronary lesions is more controversial. Several smaller randomized trials found conflicting results. Methods This is a systematic review and meta-analysis of randomized controlled trials (RCT) evaluating the effect of local Paclitaxel delivery/drug eluting balloons (DEB) (+/− bare metal stent) compared to current standard therapy (stenting) to treat de novo coronary lesions. Data sources for RCT were identified through a literature search from 2005 through 28 December 2012. The main endpoints of interest were target lesion revascularization (TLR), major adverse cardiac events (MACE), binary in-segment restenosis, stent thrombosis (ST), myocardial infarction (MI), late lumen loss (LLL) and mortality. A random effects model was used to calculate the pooled relative risks (RR) with 95% confidence intervals. Results Eight studies (11 subgroups) and a total of 1,706 patients were included in this analysis. Follow-up duration ranged from 6 to 12 months. Overall, DEB showed similar results to the comparator treatment. The relative risk (RR) for MACE was 0.95 (0.64 to 1.39); P = 0.776, for mortality it was 0.79 (0.30 to 2.11), P = 0.644, for stent thrombosis it was 1.45 (0.42 to 5.01), P = 0.560, for MI it was 1.26 (0.49 to 3.21), P = 0.629, for TLR it was 1.09 (0.71 to 1.68); P = 0.700 and for binary in-stent restenosis it was 0.96 (0.48 to 1.93), P = 0.918. Compared to bare metal stents (BMS), DEB showed a lower LLL (− 0.26 mm (−0.51 to 0.01)) and a trend towards a lower MACE risk (RR 0.66 (0.43 to 1.02)). Conclusion Overall, drug-eluting balloons (+/− bare metal stent) are not superior to current standard therapies (BMS or drug eluting stent (DES)) in treating de novo coronary lesions. However, the performance of DEB seems to lie in between DES and BMS with a trend towards superiority over BMS

  5. Stent-mediated gene and drug delivery for cardiovascular disease and cancer: A brief insight.

    PubMed

    Krishnagopal, Akshaya; Reddy, Aakash; Sen, Dwaipayan

    2017-05-01

    This review concisely recapitulates the different existing modes of stent-mediated gene/drug delivery, their considerable advancement in clinical trials and a rationale for other merging new technologies such as nanotechnology and microRNA-based therapeutics, in addition to addressing the limitations in each of these perpetual stent platforms. Over the past decade, stent-mediated gene/drug delivery has materialized as a hopeful alternative for cardiovascular disease and cancer in contrast to routine conventional treatment modalities. Regardless of the phenomenal recent developments achieved by coronary interventions and cancer therapies that employ gene and drug-eluting stents, practical hurdles still remain a challenge. The present review highlights the limitations that each of the existing stent-based gene/drug delivery system encompasses and therefore provides a vision for the future with respect to discovering an ideal stent therapeutic platform that would circumvent all the practical hurdles witnessed with the existing technology. Further study of the improvisation of next-generation drug-eluting stents has helped to overcome the issue of restenosis to some extent. However, current stent formulations fall short of the anticipated clinically meaningful outcomes and there is an explicit need for more randomized trials aiming to further evaluate stent platforms in favour of enhanced safety and clinical value. Gene-eluting stents may hold promise in contributing new ideas for stent-based prevention of in-stent restenosis through genetic interventions by capitalizing on a wide variety of molecular targets. Therefore, the central consideration directs us toward finding an ideal stent therapeutic platform that would tackle all of the gaps in the existing technology. Copyright © 2017 John Wiley & Sons, Ltd.

  6. Cost-effectiveness of drug-eluting coronary stents in Quebec, Canada.

    PubMed

    Brophy, James M; Erickson, Lonny J

    2005-01-01

    The aim of this investigation was to assess the incremental cost-effectiveness of replacing bare metal coronary stents (BMS) with drug-eluting stents (DES) in the Province of Quebec, Canada. The strategy used was a cost-effectiveness analysis from the perspective of the health-care provider, in the province of Quebec, Canada (population 7.5 million). The main outcome measure was the cost per avoided revascularization intervention. Based on the annual Quebec rate of 14,000 angioplasties with an average of 1.7 stents per procedure and a purchase cost of $2,600 Canadian dollar (CDN) for DES, 100 percent substitution of BMS with DES would require an additional $45.1 million CDN of funding. After the benefits of reduced repeat revascularization interventions are included, the incremental cost would be $35.2 million CDN. The cost per avoided revascularization intervention (18 percent coronary artery bypass graft, 82 percent percutaneous coronary intervention [PCI]) would be $23,067 CDN. If DES were offered selectively to higher risk populations, for example, a 20 percent subgroup with a relative restenosis risk of 2.5 times the current bare metal rate, the incremental cost of the program would be $4.9 million CDN at a cost of $7,800 per avoided revascularization procedure. Break-even costs for the program would occur at DES purchase cost of $1,161 for 100 percent DES use and $1,627 for selective 20 percent DES use for high-risk patients for restenosis (RR = 2.5). Univariate and Monte Carlo sensitivity analyses indicate that the parameters most affecting the analysis are the capacity to select patients at high risk of restenosis, the average number of stents used per PCI, baseline restenosis rates for BMS, the effectiveness ratio of restenosis prevention for DES versus BMS, the cost of DES, and the revascularization rate after initial PCI. Sensitivity analyses suggest little additional health benefits but escalating cost-effectiveness ratios once a DES penetration of 40

  7. Drug-eluting stents versus bare-metal stents in saphenous vein grafts: a double-blind, randomised trial.

    PubMed

    Brilakis, Emmanouil S; Edson, Robert; Bhatt, Deepak L; Goldman, Steven; Holmes, David R; Rao, Sunil V; Shunk, Kendrick; Rangan, Bavana V; Mavromatis, Kreton; Ramanathan, Kodangudi; Bavry, Anthony A; Garcia, Santiago; Latif, Faisal; Armstrong, Ehrin; Jneid, Hani; Conner, Todd A; Wagner, Todd; Karacsonyi, Judit; Uyeda, Lauren; Ventura, Beverly; Alsleben, Aaron; Lu, Ying; Shih, Mei-Chiung; Banerjee, Subhash

    2018-05-19

    Few studies have examined the efficacy of drug-eluting stents (DES) for reducing aortocoronary saphenous vein bypass graft (SVG) failure compared with bare-metal stents (BMS) in patients undergoing stenting of de-novo SVG lesions. We assessed the risks and benefits of the use of DES versus BMS in de-novo SVG lesions. Patients were recruited to our double-blind, randomised controlled trial from 25 US Department of Veterans Affairs centres. Eligible participants were aged at least 18 years and had at least one significant de-novo SVG lesion (50-99% stenosis of a 2·25-4·5 mm diameter SVG) requiring percutaneous coronary intervention with intent to use embolic protection devices. Enrolled patients were randomly assigned, in a 1:1 ratio, by phone randomisation system to receive a DES or BMS. Randomisation was stratified by presence or absence of diabetes and number of target SVG lesions requiring percutaneous coronary intervention (one or two or more) within each participating site by use of an adaptive scheme intended to balance the two stent type groups on marginal totals for the stratification factors. Patients, referring physicians, study coordinators, and outcome assessors were masked to group allocation. The primary endpoint was the 12-month incidence of target vessel failure, defined as the composite of cardiac death, target vessel myocardial infarction, or target vessel revascularisation. The DIVA trial is registered with ClinicalTrials.gov, number NCT01121224. Between Jan 1, 2012, and Dec 31, 2015, 599 patients were randomly assigned to the stent groups, and the data for 597 patients were used. The patients' mean age was 68·6 (SD 7·6) years, and 595 (>99%) patients were men. The two stent groups were similar for most baseline characteristics. At 12 months, the incidence of target vessel failure was 17% (51 of 292) in the DES group versus 19% (58 of 305) in the BMS group (adjusted hazard ratio 0·92, 95% CI 0·63-1·34, p=0·70). Between-group differences in

  8. A randomized study to compare bioactive titanium stents and everolimus-eluting stents in diabetic patients (TITANIC XV): 1-year results.

    PubMed

    López-Mínguez, José R; Nogales-Asensio, Juan M; Doncel-Vecino, Luis J; Merchán-Herrera, Antonio; Pomar-Domingo, Francisco; Martínez-Romero, Pedro; Fernández-Díaz, José A; Valdesuso-Aguilar, Raúl; Moreu-Burgos, José; Díaz-Fernández, José

    2014-07-01

    Up to 25% of patients who undergo a percutaneous coronary intervention show some limitation in the use of drug-eluting stents. The aim of this study was to evaluate if titanium-nitride-oxide-coated stents could be a good alternative to everolimus-eluting stents in diabetic patients. A total of 173 diabetic patients with lesions at moderate risk of restenosis (exclusion criteria: diameter < 2.5 mm or length > 28 mm in vessels < 3mm, chronic occlusion) were randomized to a titanium group (83 patients) or an everolimus group (90 patients). Baseline characteristics were well balanced; 28.3% of patients were insulin dependent. At 1 year, the incidence of major adverse cardiac events (death, nonfatal myocardial infarction, stroke, or repeat target vessel revascularization) was significantly higher in the titanium group than in the everolimus group (total, 14.5% vs 4.4%; P = .02; noninsulin-dependent subgroup, 9.7% vs 3.2%; P = .14; insulin-dependent subgroup, 28.6% vs 7.1%; P = .04). The incidence of death, nonfatal myocardial infarction, stroke, or any revascularization was 16.9% in the titanium group and 7.8% in the everolimus group (P = .06). Target lesion and vessel revascularizations occurred in 8.4% compared with 3.3% (P = .15) and in 13.3% compared with 3.3% (P = .01) in the titanium and everolimus groups, respectively. Angiographic follow-up at 9 months showed significantly less late lumen loss in the everolimus group (in-segment, 0.52 [standard deviation, 0.58) mm vs -0.05 [0.32] mm; in-stent, 0.76 [0.54] mm vs 0.13 [0.31] mm; P < .0001). The everolimus-eluting stent is superior to the titanium stent for clinical and angiographic end points in diabetic patients with lesions at moderate risk of restenosis. Copyright © 2013 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  9. Long-term outcome after drug-eluting versus bare-metal stent implantation in patients with ST-segment elevation myocardial infarction: 5 years follow-up from the randomized DEDICATION trial (Drug Elution and Distal Protection in Acute Myocardial Infarction).

    PubMed

    Holmvang, Lene; Kelbæk, Henning; Kaltoft, Anne; Thuesen, Leif; Lassen, Jens Flensted; Clemmensen, Peter; Kløvgaard, Lene; Engstrøm, Thomas; Bøtker, Hans E; Saunamäki, Kari; Krusell, Lars R; Jørgensen, Erik; Tilsted, Hans-Henrik; Christiansen, Evald H; Ravkilde, Jan; Køber, Lars; Kofoed, Klaus Fuglsang; Terkelsen, Christian J; Helqvist, Steffen

    2013-06-01

    This study sought to compare the long-term effects of drug-eluting stent (DES) compared with bare-metal stent (BMS) implantation in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention. The randomized DEDICATION (Drug Elution and Distal Protection in Acute Myocardial Infarction) trial evaluated the outcome after DES compared with BMS implantation in patients with STEMI undergoing primary percutaneous coronary intervention. Patients with a high-grade stenosis/occlusion of a native coronary artery presenting with symptoms <12 h and ST-segment elevation were enrolled after giving informed consent. Patients were randomly assigned to receive a DES or a BMS in the infarct-related lesion. Patients were followed for at least 5 years, and clinical endpoints were evaluated from population registries and hospital charts. The main endpoint was the occurrence of the first major adverse cardiac event (MACE), defined as cardiac death, nonfatal recurrent myocardial infarction, and target lesion revascularization. Complete clinical status was available in 623 patients (99.5%) at 5 years follow-up. The combined MACE rate was insignificantly lower in the DES group (16.9% vs. 23%), mainly driven by a lower need of repeat revascularization (p = 0.07). Whereas the number of deaths from all causes tended to be higher in the DES group (16.3% vs. 12.1%, p = 0.17), cardiac mortality was significantly higher (7.7% vs. 3.2%, p = 0.02). The 5-year stent thrombosis rates were generally low and similar between the DES and the BMS groups. No cardiac deaths occurring within 1 month could be clearly ascribed to stent thrombosis, whereas stent thrombosis was involved in 78% of later-occurring deaths. The 5-year MACE rate was insignificantly different, but the cardiac mortality was higher after DES versus BMS implantation in patients with STEMI. Stent thrombosis was the main cause of late cardiac deaths. Copyright © 2013 American

  10. The Effect of Cilostazol on the Angiographic Outcome of Drug-Eluting Coronary Stents Angiographic Analysis of the CILON-T (Influence of CILostazol-Based Triple Antiplatelet Therapy ON Ischemi Complication after Drug-Eluting StenT Implantation) Trial.

    PubMed

    Suh, Jung-Won; Lee, Seung-Pyo; Park, KyungWoo; Kang, Hyun-Jae; Koo, Bon-Kwon; Cho, Young-Seok; Youn, Tae-Jin; Chae, In-Ho; Choi, Dong-Ju; Rha, Seung-Woon; Bae, Jang-Ho; Kwon, Taek-Geun; Bae, Jang-Whan; Cho, Myeong-Chan; Kim, Hyo-Soo

    2017-12-12

    It is not clear if anti-restonotic effect of cilostazol is consistent for different types of drug-eluting stents (DES).The purpose of this study was to compare the anti-proliferative effect of cilostazol between DAT and TAT with consideration of confounding influences of DES type.Nine hundred and fifteen patients were randomized to either dual antiplatelet therapy (DAT; aspirin and clopidogrel) or triple antiplatelet therapy (TAT; aspirin, clopidogrel, and cilostazol) in the previous CILON-T trial. After excluding 70 patients who received both or neither stents, we analyzed 845 patients who received exclusively PES or ZES, and compared in-stent late loss at 6 months between both antiplatelet regimens (DAT versus TAT).Baseline angiographic and clinical characteristics were similar between the DAT (656 lesions in 425 patients) and the TAT group (600 lesions in 420 patients). The 6-month follow-up angiography was completed in 745 patients (88.2%). Quantitative coronary angiography showed that TAT significantly reduced in-stent late loss (DAT 0.62 ± 0.62 mm versus TAT 0.54 ± 0.49 mm, P = 0.015). Stent type, diabetes or lesion length did not interact with difference of late loss. However, reduction of late loss by cilostazol did not lead to a significant reduction in the rate of target lesion revascularization (TLR) (DAT 7.8% versus TAT 6.9%, P = 0.69) due to a nonlinear relationship found between late loss and TLR.The TAT group showed less in-stent late loss as compared to the DAT group. This was consistently observed regardless of DES type, lesion length, or diabetic status. However, reduction of late loss by cilostazol did not lead to a significant reduction in TLR.

  11. Nine-Months Clinical Outcome of Biodegradable Polymer Coated Sirolimus-eluting Stent System: A Multi-Centre "Real-World" Experience.

    PubMed

    Sarma, Raghava; Prajapati, Jayesh; Raheem, Asif; Thakkar, Kamlesh; Kothari, Shivani; Thakkar, Ashok

    2015-08-01

    The main culprit in first-generation drug eluting stents is 'durable' polymer, whose continuous presence may impair arterial healing and ultimately have a negative impact on late outcomes. The main enigma behind the biodegradable polymer usage is its degradation after elution of drug. This reduces adverse events in unselected patients with complex coronary artery lesions treated with biodegradable polymer coated sirolimus-eluting stents. The aim of the INDOLIMUS-G Registry was to evaluate safety and efficacy of the Indolimus (Sahajanand Medical Technologies Pvt. Ltd., Surat, India) sirolimus-eluting stents in large cohorts of unselected patients with complex coronary artery lesions. It is a multi-centre, non-randomized retrospective registry with a clear aim of evaluating safety and efficacy of the Indolimus sirolimus-eluting stents in consecutive patients enrolled between April 2012 and May 2014. The primary end-point of the study was major adverse cardiac events (MACE), which is a composite of cardiac death, myocardial infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR) and stent thrombosis (ST) at the end of follow-up. Clinical follow-up were scheduled at the end of 30-days, 6-months, and 9-months period. The mean age of enrolled patients was 52.6 ± 11.0 years. A total of 1137 lesions were intervened successfully with 1242 stents (1.09 ± 0.30 stent per lesion). The average stent length and diameter was 27.42 ± 9.01 mm and 3.12 ± 0.36 mm respectively. There were 740 (73.40%) male patients, indicating their high prevalence. Diabetes, hypertension and totally occluded lesions were found in 372 (36.90%), 408 (40.47%) and 170 (16.86%) patients, respectively. This showed that study also included high risk complex lesions and not ideal recruited lesions. The incidence of MACE at 30-days, 6-months and 9-months were 3 (0.30%), 18 (1.80%) and 22 (2.20%) respectively. At 9-months, TLR was found in 6 (0.50%) patients. There were

  12. Randomized Comparison of Ridaforolimus- and Zotarolimus-Eluting Coronary Stents in Patients With Coronary Artery Disease: Primary Results From the BIONICS Trial (BioNIR Ridaforolimus-Eluting Coronary Stent System in Coronary Stenosis).

    PubMed

    Kandzari, David E; Smits, Pieter C; Love, Michael P; Ben-Yehuda, Ori; Banai, Shmuel; Robinson, Simon D; Jonas, Michael; Kornowski, Ran; Bagur, Rodrigo; Iniguez, Andres; Danenberg, Haim; Feldman, Robert; Jauhar, Rajiv; Chandna, Harish; Parikh, Manish; Perlman, Gidon Y; Balcells, Mercedes; Markham, Peter; Ozan, Melek Ozgu; Genereux, Philippe; Edelman, Elazer R; Leon, Martin B; Stone, Gregg W

    2017-10-03

    The safety and efficacy of a novel cobalt alloy-based coronary stent with a durable elastomeric polymer eluting the antiproliferative agent ridaforolimus for treatment of patients with coronary artery disease is undetermined. A prospective, international 1:1 randomized trial was conducted to evaluate in a noninferiority design the relative safety and efficacy of ridaforolimus-eluting stents (RESs) and slow-release zotarolimus-eluting stents among 1919 patients undergoing percutaneous coronary intervention at 76 centers. Inclusion criteria allowed enrollment of patients with recent myocardial infarction, total occlusions, bifurcations lesions, and other complex conditions. Baseline clinical and angiographic characteristics were similar between the groups. Overall, mean age was 63.4 years, 32.5% had diabetes mellitus, and 39.7% presented with acute coronary syndromes. At 12 months, the primary end point of target lesion failure (composite of cardiac death, target vessel-related myocardial infarction, and target lesion revascularization) was 5.4% for both devices (upper bound of 1-sided 95% confidence interval 1.8%, P noninferiority =0.001). Definite/probable stent thrombosis rates were low in both groups (0.4% RES versus 0.6% zotarolimus-eluting stent, P =0.75); 13-month angiographic in-stent late lumen loss was 0.22±0.41 mm and 0.23±0.39 mm ( P noninferiority =0.004) for the RES and zotarolimus-eluting stent groups, respectively, and intravascular ultrasound percent neointimal hyperplasia was 8.10±5.81 and 8.85±7.77, respectively ( P noninferiority =0.01). In the present trial, which allowed broad inclusion criteria, the novel RESs met the prespecified criteria for noninferiority compared with zotarolimus-eluting stents for the primary end point of target lesion failure at 12 months and had similar measures of late lumen loss. These findings support the safety and efficacy of RESs in patients who are representative of clinical practice. URL: http

  13. Long-term clinical outcomes of biodegradable polymer biolimus-eluting stents versus durable polymer everolimus-eluting stents in patients with coronary artery disease: three-year follow-up of the COMPARE II (Abluminal biodegradable polymer biolimus-eluting stent versus durable polymer everolimus-eluting stent) trial.

    PubMed

    Vlachojannis, Georgios J; Smits, Pieter C; Hofma, Sjoerd H; Togni, Mario; Vázquez, Nicolás; Valdés, Mariano; Voudris, Vassilis; Puricel, Serban; Slagboom, Ton; Goy, Jean-Jacques; den Heijer, Peter; van der Ent, Martin

    2015-07-01

    The aim of this analysis was to compare the long-term safety and efficacy of the biodegradable polymer biolimus-eluting stent (BES) with that of the durable polymer everolimus-eluting stent (EES). The COMPARE II study was a prospective, randomised, multicentre, all-comers trial in which 2,707 patients were randomly allocated (2:1) to BES or EES. The pre-specified endpoint at three years was major adverse cardiac events (MACE), a composite of cardiac death, non-fatal myocardial infarction (MI), or target vessel revascularisation (TVR). Moreover, the combined endpoint all-cause death or MI was analysed as a safety, and TVR as an efficacy measure. Three-year follow-up was available in 2,683 patients (99.1%). At three years, MACE occurred in 213 patients (11.9%) in the BES group and in 101 patients (11.1 %) in the EES group (p=0.57). The rate of the combined safety endpoint all-cause death or MI was 9.3% in the BES group vs. 8.4% (p=0.52), while the efficacy measure TVR was 7.6% in BES vs. 6.5% (p=0.27). Interestingly, definite stent thrombosis rates did not differ between groups (1.2% for BES vs. 0.8%, p=0.33). At three-year follow-up, MACE as well as safety and efficacy measures including stent thrombosis were not statistically different between the biodegradable polymer-coated BES and the durable polymer-coated EES. ClinicalTrials.gov Identifier: NCT01233453.

  14. Comparison of cost-effectiveness of oral rapamycin plus bare-metal stents versus first generation of drug-eluting stents (from the Randomized Oral Rapamycin in Argentina [ORAR] 3 trial).

    PubMed

    Rodriguez, Alfredo E; Palacios, Igor; Rodriguez-Granillo, Alfredo M; Mieres, Juan R; Tarragona, Sonia; Fernandez-Pereira, Carlos; Solorzano, Leonardo; Pauletto, Ricardo; Serruys, Patrick W; Antoniucci, David

    2014-03-01

    The aim of this study was to compare 5-year cost-effectiveness and clinical outcomes of patients with oral rapamycin (OR) plus bare-metal stent versus the drug-eluting stent (DES) strategy. During 2006 to 2007, a total of 200 patients were randomized to OR (n = 100) and DES (n = 100). Primary end point was to compare costs of initial procedure and cost-effectiveness of both revascularization strategies. Safety was evaluated by the composite of death, myocardial infarction, and cerebrovascular accident. Efficacy was assessed by target vessel and target lesion revascularizations. The 2 groups had similar baseline demographic, clinical, and angiographic characteristics. In the DES group, paclitaxel-, zotarolimus-, and sirolimus-eluting stents were used. Five-year clinical follow-up was accomplished in 99% patients. The DES group had significantly higher procedural (p <0.001), discharge to first-year (p = 0.02), and 1- to 5-year costs (p <0.001) compared with the OR group. At 5 years, the composite end point of death, myocardial infarction, and cerebrovascular accident (12% in the OR group vs 25% in the DES group, p = 0.01) was significantly less in the OR group. Target vessel revascularization (14.5% in the OR group vs 21% in the DES group, p = 0.16) and target lesion revascularization (10% in the OR group vs 17.6% in the DES group, p = 0.05) were not significantly different. In conclusion, a strategy of OR plus bare-metal stent was cost saving than a first-generation DES. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. First Report of the Resolute Onyx 2.0-mm Zotarolimus-Eluting Stent for the Treatment of Coronary Lesions With Very Small Reference Vessel Diameter.

    PubMed

    Price, Matthew J; Saito, Shigeru; Shlofmitz, Richard A; Spriggs, Douglas J; Attubato, Michael; McLaurin, Brent; Popma Almonacid, Alexandra; Brar, Sandeep; Liu, Minglei; Moe, Elizabeth; Mehran, Roxana

    2017-07-24

    The aim of this study was to explore the safety and efficacy of a dedicated drug-eluting stent for the treatment of coronary lesions with very small reference vessel diameter (RVD). Smaller RVD is associated with increased risk for restenosis and target lesion failure (TLF) after stent implantation. This was a prospective, single-arm, multicenter trial of the Resolute Onyx 2.0-mm zotarolimus-eluting stent. The primary endpoint was 12-month TLF, which was compared with a pre-specified performance goal. Subjects with stable or unstable angina or ischemia, target lesions ≤27 mm in length, and RVD ≥2.0 and <2.25 mm were eligible for enrollment. A subset of subjects underwent follow-up angiography at 13 months post-procedure. A total of 101 subjects with 104 lesions were enrolled. The mean age was 67.3 ± 9.6 years, 47% of subjects had diabetes, the mean lesion length was 12.6 ± 6.3 mm, and the mean RVD was 1.91 ± 0.26 mm. The rate of TLF at 12 months was 5.0%, fulfilling the pre-specified performance goal of 19% (p < 0.001). The rates of target lesion revascularization and target vessel myocardial infarction were 2.0% and 3.0%, respectively. There were no episodes of stent thrombosis. In-stent late lumen loss was 0.26 ± 0.48 mm, and the rate of binary restenosis was 12.0%. In this first report of a drug-eluting stent with a dedicated size to treat lesions with RVD <2.25 mm, the Resolute Onyx 2.0-mm zotarolimus-eluting stent was associated with a low rate of TLF and late lumen loss, without a signal for stent thrombosis. This novel-sized drug-eluting stent appears to be a feasible option for the treatment of coronary lesions in extremely small vessels. (Medtronic Resolute Onyx 2.0 mm Clinical Study; NCT02412501). Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  16. Red blood cell distribution width and long-term outcome in patients undergoing percutaneous coronary intervention in the drug-eluting stenting era: a two-year cohort study.

    PubMed

    Yao, Hai-Mu; Sun, Tong-Wen; Zhang, Xiao-Juan; Shen, De-Liang; Du, You-You; Wan, You-Dong; Zhang, Jin-Ying; Li, Ling; Zhao, Luo-Sha

    2014-01-01

    Previous studies suggest the higher the red blood cell distribution width (RDW) the greater the risk of mortality in patients with coronary artery disease (CAD). However, the relationship between RDW and long-term outcome in CAD patients undergoing percutaneous coronary intervention (PCI) with a drug-eluting stent (DES) remains unclear. This study was designed to evaluate the long-term effect of RDW in patients treated with drug-eluting stent for CAD. In total of 2169 non-anemic patients (1468 men, mean age 60.2 ± 10.9 years) with CAD who had undergone successful PCI and had at least one drug-eluting stent were included in this study. Patients were grouped according to their baseline RDW: Quartile 1 (RDW<12.27%), Quartile 2 (12.27% ≤ RDW <13%), Quartile 3 (13% ≤ RDW<13.5%), and Quartile 4 (RDW ≥ 13.5). The incidence of in-hospital mortality and death or myocardial infarction was significantly higher in Quartiles 3 and 4 compared with Quartile 1 (P<0.05). After a follow-up of 29 months, the incidence of all-cause death and stent thrombosis in Quartile 4 was higher than in Quartiles 1, 2, and 3 (P<0.05). The incidence of death/myocardial infarction/stroke and cardiac death in Quartile 4 was higher than in Quartiles 1 and 2 (P<0.05). Multivariate Cox regression analysis showed that RDW was an independent predictor of all-cause death (hazard ratio (HR) = 1.37, 95% confidence interval (CI) = 1.15-1.62, P<0.001) and outcomes of death/myocardial infarction/stroke (HR = 1.21, 95% CI = 1.04-1.39, P = 0.013). The cumulative survival rate of Quartile 4 was lower than that of Quartiles 1, 2, and 3 (P<0.05). High RDW is an independent predictor of long-term adverse clinical outcomes in non-anemic patients with CAD treated with DES.

  17. Very late stent thrombosis with second generation drug eluting stents compared to bare metal stents: Network meta-analysis of randomized primary percutaneous coronary intervention trials.

    PubMed

    Philip, Femi; Stewart, Susan; Southard, Jeffrey A

    2016-07-01

    The relative safety of drug-eluting stents (DES) and bare-metal stents (BMS) in primary percutaneous coronary intervention (PPCI) in ST elevation myocardial infarction (STEMI) continues to be debated. The long-term clinical outcomes between second generation DES and BMS for primary percutaneous coronary intervention (PCI) using network meta-analysis were compared. Randomized controlled trials comparing stent types (first generation DES, second generation DES, or BMS) were considered for inclusion. A search strategy used Medline, Embase, Cochrane databases, and proceedings of international meetings. Information about study design, inclusion criteria, and sample characteristics were extracted. Network meta-analysis was used to pool direct (comparison of second generation DES to BMS) and indirect evidence (first generation DES with BMS and second generation DES) from the randomized trials. Twelve trials comparing all stents types including 9,673 patients randomly assigned to treatment groups were analyzed. Second generation DES was associated with significantly lower incidence of definite or probable ST (OR 0.59, 95% CI 0.39-0.89), MI (OR 0.59, 95% CI 0.39-0.89), and TVR at 3 years (OR 0.50: 95% CI 0.31-0.81) compared with BMS. In addition, there was a significantly lower incidence of MACE with second generation DES versus BMS (OR 0.54, 95% CI 0.34-0.74) at 3 years. These were driven by a higher rate of TVR, MI and stent thrombosis in the BMS group at 3 years. There was a non-significant reduction in the overall and cardiac mortality [OR 0.83, 95% CI (0.60-1.14), OR 0.88, 95% CI (0.6-1.28)] with the use of second generation DES versus BMS at 3 years. Network meta-analysis of randomized trials of primary PCI demonstrated lower incidence of MACE, MI, TVR, and stent thrombosis with second generation DES compared with BMS. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  18. Ultrasonic atomization and subsequent desolvation for monoclonal antibody (mAb) to the glycoprotein (GP) IIIa receptor into drug eluting stent.

    PubMed

    Wang, G X; Luo, L L; Yin, T Y; Li, Y; Jiang, T; Ruan, C G; Guidoin, R; Chen, Y P; Guzman, R

    2010-01-01

    An eluting-stent system with mAb dispersed in the PLLA (poly (L-lactic acid)) was validated in vitro. Specifically designed spray equipment based on the principle of ultrasonic atomization was used to produce a thin continuous PLLA (poly (L-lactic acid)) polymer coating incorporating monoclonal antibody (mAb). This PLLA coating was observed in light microscopy (LM) and scanning electron microscopy (SEM). The concentration of the monoclonal antibody (mAb) to the platelet glycoprotein (GP) IIIa receptor and the eluting rate were then measured by a radioisotope technique with (125)I-labelled GP IIIa mAb. An in vitro perfusion circuit was designed to evaluate the release rates at different velocities (10 or 20 ml min(-1)). The PLLA coating was thin and transparent, uniformly distributed on the surface of the stent. Three factors influenced its thickness: PLLA concentration, duration and gas pressure. The concentration of mAb was influenced by the duration of absorption and the concentration of the mAb solution; the maximum was 1662.23 + or - 38.83 ng. The eluting rate was fast for the first 2 h, then decreased slowly and attained 80% after 2 weeks. This ultrasonic atomization spray equipment and technological process to prepare protein eluting-stents were proved to be effective and reliable.

  19. Clinical Outcomes of Patients Undergoing Rotational Atherectomy Followed by Drug-eluting Stent Implantation: A Single-center Real-world Experience

    PubMed Central

    Cuenza, Lucky R.; Jayme, Ada Cherryl; Khe Sui, James Ho

    2017-01-01

    Background: Rotational atherectomy (RA) is used to improve procedural success of percutaneous catheter interventions (PCIs) of complex and heavily calcified coronary lesions. We report the clinical experience and outcomes in our institution with the use of RA, followed by drug-eluting stent implantation. Materials and Methods: Data of 81 patients treated with PCI and adjunctive RA were analyzed. Clinical follow-up for the occurrence of major adverse events (MAEs) was obtained in all patients and correlated with significant variables using multivariate Cox proportional hazards analysis. Results: Mean age was 67.9 ± 9.2 years, 61.7% had diabetes, 20.9% had chronic kidney disease, and 48.1% had previous acute coronary syndrome (ACS). Mean SYNTAX score was 29.8 ± 12.2, with a 92.5% angiographic success rate achieved. In-hospital MAEs rate was 7.4% while mortality rate was 8.6%. On median follow-up of 12.2 months, incidence of MAEs of 13.5% with a 75% free incidence from MAEs at 34 months. Multivariate analysis revealed that a history of previous ACS, ejection fraction, neutrophil to lymphocyte ratio, platelet to lymphocyte ratio, SYNTAX score, burr to artery ratio, and attainment of angiographic success were significant predictors of MAEs. Conclusion: RA followed by drug-eluting stent implantation is a safe and effective method in improving procedural success as well as short- and long-term outcomes of PCI in our center. A combination of clinical and procedural factors is predictive for the occurrence of MAEs and should be taken into account in the application of this technique. PMID:29326773

  20. Randomized Comparison of Ridaforolimusand Zotarolimus-Eluting Coronary Stents in Patients With Coronary Artery Disease

    PubMed Central

    Kandzari, David E.; Smits, Pieter C.; Love, Michael P.; Ben-Yehuda, Ori; Banai, Shmuel; Rob-inson, Simon D.; Jonas, Michael; Kornowski, Ran; Bagur, Rodrigo; Iniguez, Andres; Danenberg, Haim; Feldman, Robert; Jauhar, Rajiv; Chandna, Harish; Parikh, Manish; Perlman, Gidon Y.; Balcells, Mer-cedes; Markham, Peter; Ozan, Melek Ozgu; Genereux, Philippe; Edelman, Elazer R.; Leon, Martin B.; Stone, Gregg W.

    2018-01-01

    BACKGROUND The safety and efficacy of a novel cobalt alloy-based coronary stent with a durable elastomeric polymer eluting the antiproliferative agent ridaforolimus for treatment of patients with coronary artery disease is undetermined. METHODS A prospective, international 1:1 randomized trial was conducted to evaluate in a noninferiority design the relative safety and efficacy of ridaforolimus-eluting stents (RESs) and slow-release zotarolimus-eluting stents among 1919 patients undergoing percutaneous coronary intervention at 76 centers. Inclusion criteria allowed enrollment of patients with recent myocardial infarction, total occlusions, bifurcations lesions, and other complex conditions. RESULTS Baseline clinical and angiographic characteristics were similar between the groups. Overall, mean age was 63.4 years, 32.5% had diabetes mellitus, and 39.7% presented with acute coronary syndromes. At 12 months, the primary end point of target lesion failure (composite of cardiac death, target vessel-related myocardial infarction, and target lesion revascularization) was 5.4% for both devices (upper bound of 1-sided 95% confidence interval 1.8%, Pnoninferiority=0.001). Definite/probable stent thrombosis rates were low in both groups (0.4% RES versus 0.6% zotarolimus-eluting stent, P=0.75); 13-month angiographic in-stent late lumen loss was 0.22±0.41 mm and 0.23±0.39 mm (Pnoninferiority=0.004) for the RES and zotarolimus-eluting stent groups, respectively, and intravascular ultrasound percent neointimal hyperplasia was 8.10±5.81 and 8.85±7.77, respectively (Pnoninferiority=0.01). CONCLUSIONS In the present trial, which allowed broad inclusion criteria, the novel RESs met the prespecified criteria for noninferiority compared with zotarolimus-eluting stents for the primary end point of target lesion failure at 12 months and had similar measures of late lumen loss. These findings support the safety and efficacy of RESs in patients who are representative of clinical

  1. Effectiveness of Drug-Eluting Stents versus Bare-Metal Stents in Large Coronary Arteries in Patients with Acute Myocardial Infarction

    PubMed Central

    Sim, Doo Sun; Ahn, Youngkeun; Kim, Young Jo; Chae, Shung Chull; Hong, Taek Jong; Seong, In Whan; Chae, Jei Keon; Kim, Chong Jin; Cho, Myeong Chan; Seung, Ki Bae; Park, Seung Jung

    2011-01-01

    This study compared clinical outcomes of drug-eluting stents (DES) versus bare-metal stents (BMS) in large coronary arteries in patients with acute myocardial infarction (MI). A total of 985 patients who underwent single-vessel percutaneous coronary intervention (PCI) in large coronary arteries (≥ 3.5 mm) in lesions < 25 mm were divided into DES group (n = 841) and BMS group (n = 144). Clinical outcomes during 12 months were compared. In-hospital outcome was similar between the groups. At six months, death/MI rate was not different. However, DES group had significantly lower rates of target-lesion revascularization (TLR) (1.7% vs 5.6%, P = 0.021), target-vessel revascularization (TVR) (2.2% vs 5.6%, P = 0.032), and total major adverse cardiac events (MACE) (3.4% vs 11.9%, P = 0.025). At 12 months, the rates of TLR and TVR remained lower in the DES group (2.5% vs 5.9%, P = 0.032 and 5.9% vs 3.1%, P = 0.041), but the rates of death/MI and total MACE were not statistically different. The use of DES in large vessels in the setting of acute MI is associated with lower need for repeat revascularization compared to BMS without compromising the overall safety over the course of one-year follow-up. PMID:21468259

  2. Enhancing Stent Effectiveness with Nanofeatures

    PubMed Central

    Bassous, Nicole; Cooke, John P.; Webster, Thomas J.

    2016-01-01

    Drug-eluting stents are an effective therapy for symptomatic arterial obstructions, substantially reducing the incidence of restenosis by suppressing the migration and proliferation of vascular smooth muscle cells into the intima. However, current drug-eluting stents also inhibit the growth of endothelial cells, which are required to cover the vascular stent to reduce an excessive inflammatory response. As a result, the endothelial lining of the lumen is not regenerated. Since the loss of this homeostatic monolayer increases the risk of thrombosis, patients with drug-eluting stents require long-term antithrombotic therapy. Thus, there is a need for improved devices with enhanced effectiveness and physiological compatibility towards endothelial cells. Current developments in nanomaterials may enhance the function of commercially available vascular devices. In particular, modified design schemes might incorporate nanopatterns or nanoparticle-eluting features that reduce restenosis and enhance re-endothelialization. The intent of this review is to discuss emerging nanotechnologies that will improve the performance of vascular stents. PMID:27826371

  3. Real-World Bioresorbable Vascular Scaffold Experience Compared With Second-Generation Metallic Drug-Eluting Stents in Complex Coronary Lesions.

    PubMed

    Okamoto, Naotaka; Ueda, Hiroshi; Yoshimura, Takahiro; Chamaria, Surbhi; Bhatheja, Samit; Vengrenyuk, Yuliya; Rabiei, Samaneh; Barrientos, Yonandy; Kapur, Vishal; Barman, Nitin; Sweeny, Joseph; Baber, Usman; Mehran, Roxana; Sharma, Samin K; Kini, Annapoorna S

    2018-04-15

    The aim of the study was to compare the acute outcomes of Absorb bioresorbable vascular scaffolds (BVS) and second-generation drug-eluting stent (DES) implantation in routine clinical practice. There is a paucity of data regarding BVS use in a real-world patient population. The study population comprised 40 consecutive patients who underwent percutaneous coronary intervention (PCI) with BVS implantation at a tertiary-care center in New York, New York between July and December of 2016. An optimal implantation technique including adequate lesion preparation, mandatory postdilation, and optical coherence tomography (OCT) imaging was used in all cases. De novo lesions treated with BVS were compared to lesions treated with DES matched by OCT calcium arc, scaffold/stent size, use of atherectomy device, and lesion postdilation. Acute lumen gain, minimal device area, malapposition, eccentricity, and symmetry index were assessed using OCT. We analyzed OCT images of 40 BVS cases and 40 matching DES cases from 35 and 40 patients, respectively. Compared to the DES group, the BVS group demonstrated similar acute lumen gain, minimal scaffold/stent area, eccentricity index, and symmetry index after PCI. There were fewer malapposed struts detected after BVS implantation; however, malapposition distance and length were not different between the groups. BVS implantation in a real-world patient population with optimal implantation technique resulted in similar stent expansion and better strut apposition compared to DES implantation.

  4. Comparison of 3 biodegradable polymer and durable polymer-based drug-eluting stents in all-comers (BIO-RESORT): rationale and study design of the randomized TWENTE III multicenter trial.

    PubMed

    Lam, Ming Kai; Sen, Hanim; Tandjung, Kenneth; van Houwelingen, K Gert; de Vries, Arie G; Danse, Peter W; Schotborgh, Carl E; Scholte, Martijn; Löwik, Marije M; Linssen, Gerard C M; Ijzerman, Maarten J; van der Palen, Job; Doggen, Carine J M; von Birgelen, Clemens

    2014-04-01

    To evaluate the safety and efficacy of 2 novel drug-eluting stents (DES) with biodegradable polymer-based coatings versus a durable coating DES. BIO-RESORT is an investigator-initiated, prospective, patient-blinded, randomized multicenter trial in 3540 Dutch all-comers with various clinical syndromes, requiring percutaneous coronary interventions (PCI) with DES implantation. Randomization (stratified for diabetes mellitus) is being performed in a 1:1:1 ratio between ORSIRO sirolimus-eluting stent with circumferential biodegradable coating, SYNERGY everolimus-eluting stent with abluminal biodegradable coating, and RESOLUTE INTEGRITY zotarolimus-eluting stent with durable coating. The primary endpoint is the incidence of the composite endpoint target vessel failure at 1 year, consisting of cardiac death, target vessel-related myocardial infarction, or clinically driven target vessel revascularization. Power calculation assumes a target vessel failure rate of 8.5% with a 3.5% non-inferiority margin, giving the study a power of 85% (α level .025 adjusted for multiple testing). The impact of diabetes mellitus on post-PCI outcome will be evaluated. The first patient was enrolled on December 21, 2012. BIO-RESORT is a large, prospective, randomized, multicenter trial with three arms, comparing two DES with biodegradable coatings versus a reference DES with a durable coating in 3540 all-comers. The trial will provide novel insights into the clinical outcome of modern DES and will address the impact of known and so far undetected diabetes mellitus on post-PCI outcome. Copyright © 2014 The Authors. Published by Mosby, Inc. All rights reserved.

  5. Thrombosis of second-generation drug-eluting stents in real practice results from the multicenter Spanish registry ESTROFA-2 (Estudio Español Sobre Trombosis de Stents Farmacoactivos de Segunda Generacion-2).

    PubMed

    de la Torre Hernández, José M; Alfonso, Fernando; Gimeno, Federico; Diarte, Jose A; Lopez-Palop, Ramón; Pérez de Prado, Armando; Rivero, Fernando; Sanchis, Juan; Larman, Mariano; Diaz, Jose F; Elizaga, Jaime; Moreiras, Javier Martín; Gomez Jaume, Alfredo; Hernández, José M; Mauri, Josepa; Recalde, Angel Sánchez; Bullones, Juan A; Rumoroso, Jose R; Del Blanco, Bruno García; Baz, Jose A; Bosa, Francisco; Botas, Javier; Hernández, Felipe

    2010-09-01

    This study sought to evaluate second-generation drug-eluting stent (DES) thrombosis in clinical practice. First-generation DES are associated with a significant incidence of late thrombosis. There is paucity of data regarding real practice late thrombosis incidence and predictors with second-generation DES, zotarolimus-eluting stent (ZES), and everolimus-eluting stents (EES). A prospective, large-scale, non-industry-linked multicenter registry was designed. Complete clinical-procedural data and systematic follow-up of all patients treated with these stents was reported in a dedicated registry supported by the Spanish Working Group on Interventional Cardiology. From 2005 to 2008, 4,768 patients were included in 34 centers: 2,549 treated with ZES, and 2,219 with EES. The cumulative incidence of definite/probable thrombosis for ZES was 1.3% at 1 year and 1.7% at 2 years and for EES 1.4% at 1 year and 1.7% at 2 years (p = 0.8). The increment of definite thrombosis between the first and second year was 0.2% and 0.25%, respectively. In a propensity score analysis, the incidence remained very similar. Ejection fraction (adjusted hazard ratio [HR]: 0.97; 95% confidence interval [CI]: 0.95 to -0.99; p = 0.008), stent diameter (adjusted HR: 0.37; 95% CI: 0.17to 0.81; p = 0.01) and bifurcations (adjusted HR: 2.1; 95% CI: 1.14 to 3.7; p = 0.02) emerged as independent predictors of thrombosis. In the subgroup of patients with bifurcations, the use of ZES was independently associated with a higher thrombosis rate (adjusted HR: 4; 95% CI: 1.1 to 13; p = 0.03). In a real practice setting, the incidence of thrombosis at 2 years with ZES and EES was low and quite similar. The incidence of very late thrombosis resulted lower than was reported in registries of first-generation DES. In the subset of bifurcations, the use of ZES significantly increased the risk of thrombosis. Copyright © 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  6. Comparing Stent Thrombosis associated with Zotarolimus Eluting Stents versus Everolimus Eluting Stents at 1 year follow up: a systematic review and meta-analysis of 6 randomized controlled trials.

    PubMed

    Bundhun, Pravesh Kumar; Yanamala, Chandra Mouli; Huang, Wei-Qiang

    2017-03-16

    Two thousand fifteen has been a winning year for Drug Eluting Stents (DES). Increase in the number of patients with cardiovascular diseases treated by Percutaneous Coronary Intervention (PCI) has resulted to a high demand for second generation DES. This current analysis aimed to compare the different types of Stent Thrombosis (ST) associated with Zotarolimus Eluting Stents (ZES) versus Everolimus Eluting Stents (EES) at 1 year follow up. Electronic databases were searched for studies comparing ZES with EES. Different types of ST reported at 1 year follow up were considered as the primary endpoints in this analysis. Odds Ratios (OR) with 95% Confidence Intervals (CIs) were used as the statistical parameters and the pooled analyses were carried out by the RevMan 5 · 3 software. A total number of 10,512 patients were included in this analysis. No significant difference in any definite ST, acute definite ST, subacute definite ST, and late definite ST were observed between ZES and EES, at 1 year follow up with OR: 1.70, 95% CI: 0.92 - 3.16; P = 0.09, OR: 3.44, 95% CI: 0.82 - 14.43; P = 0.09, OR: 1.13, 95% CI: 0.43 - 2.95; P = 0.80 and OR: 2.39, 95% CI: 0.83 - 6.85; P = 0.11 respectively. Moreover, any definite or probable ST and definite/probable/possible ST were also not significantly different with OR: 1.39, 95% CI: 0.89 - 2.17; P = 0.15 and OR: 1.19, 95% CI: 0.84 - 1.70; P = 0.33 respectively. In addition, any probable ST, acute probable ST, late probable ST and possible ST were also not significantly different at 1 year follow up with OR: 1.11, 95% CI: 0.60 - 2.05; P = 0.75, OR: 0.53, 95% CI: 0.12 - 2.40; P = 0.41, OR: 1.67, 95% CI: 0.35 - 7.86; P = 0.52 and OR: 1.08, 95% CI: 0.64 - 1.82; P = 0.78 respectively. At 1 year follow up, ZES were not associated with significantly lower or higher definite and probable ST compared to EES. In addition, no significant difference was observed in acute, subacute and late

  7. Temporal trends in the use of drug-eluting stents for approved and off-label indications: a longitudinal analysis of a large multicenter percutaneous coronary intervention registry.

    PubMed

    Gualano, Sarah K; Gurm, Hitinder S; Share, David; Smith, Dean; Aronow, Herbert D; LaLonde, Thomas; Bates, Eric R; Changezi, Hameem; McNamara, Richard; Moscucci, Mauro

    2010-02-01

    We sought to examine the temporal variations in the rate of both bare-metal stent (BMS) and drug-eluting stent (DES) use for off-label indications after the reports of an increased risk of very late stent thrombosis in patients with DES at the 2006 meeting of the European Society of Cardiology (ESC). To determine whether the decrease in use of DES has affected both on and off-label indications. The study cohort included patients undergoing coronary intervention in a large regional registry, the Blue Cross Blue Shield of Michigan Cardiovascular Consortium (BMC2). Patient demographic and clinical characteristics for patients with DES in the third quarter of 2006 (pre-ESC) were compared to those from the fourth quarter of 2008 (post-guideline changes). Use of DES for off-label indications, such as ST-segment elevation myocardial infarction (STEMI), in-stent restenosis (ISR), and saphenous vein graft (SVG) interventions, were evaluated. The overall deployment of DES fell sharply from 83% pre-ESC to a plateau of 58% in the first quarter of 2008. This corresponded to a rise in BMS use, while angioplasty procedures stayed the same. The STEMI subgroup showed the most dramatic change, from 78% to only 36%. Off-label use in SVGs showed a similar trend, from 74% to 43%. Drug-eluting stent deployment for ISR was less affected, though it also fell 25% (from 79%-56%). The use of DES has fallen dramatically from June 2006 to December 2008, particularly for nonapproved indications. Our study provides a real-world assessment of contemporary change in DES use in response to the presentation of negative observational studies. Copyright 2010 Wiley Periodicals, Inc.

  8. Patient-tailored Drug-eluting Stent Choice - A Solution for Patients with Diabetes: Proceedings of Two Satellite Symposia Held at EuroPCR in May 2015 in Paris.

    PubMed

    Mountfort, Katrina; Mehran, Roxana; Colombo, Antonio; Stella, Pieter; Romaguera, Rafael; Sardella, Gennaro

    2015-09-01

    Although second-generation drug-eluting stents (DES) have improved outcomes in percutaneous coronary interventions (PCIs), important unmet needs remain. Two symposia at EuroPCR 2015 focused on two challenging scenarios. First, patients with diabetes mellitus (DM) have generally inferior outcomes following PCI. The Cre8™ stent (manufactured by CID Spa, member of Alvimedica Group) has shown unique efficacy in subpopulations of patients with DM during clinical trials. A live case in a patient with diabetes illustrated the challenges of complex multivessel disease. Second, optimising stent selection towards devices that have demonstrated complete and early endothelialisation offers the potential to reduce the duration of dual antiplatelet therapy. The Cre8™ DES features a polymer-free platform and has been associated with low rates of in-stent thrombosis.

  9. Cost-effectiveness of percutaneous coronary intervention with drug-eluting stents versus bypass surgery for patients with 3-vessel or left main coronary artery disease: final results from the Synergy Between Percutaneous Coronary Intervention With TAXUS and Cardiac Surgery (SYNTAX) trial.

    PubMed

    Cohen, David J; Osnabrugge, Ruben L; Magnuson, Elizabeth A; Wang, Kaijun; Li, Haiyan; Chinnakondepalli, Khaja; Pinto, Duane; Abdallah, Mouin S; Vilain, Katherine A; Morice, Marie-Claude; Dawkins, Keith D; Kappetein, A Pieter; Mohr, Friedrich W; Serruys, Patrick W

    2014-09-30

    The Synergy Between Percutaneous Coronary Intervention With TAXUS and Cardiac Surgery (SYNTAX) trial demonstrated that in patients with 3-vessel or left main coronary artery disease, coronary artery bypass graft surgery (CABG) was associated with a lower rate of cardiovascular death, myocardial infarction, stroke, or repeat revascularization compared with percutaneous coronary revascularization with drug-eluting stents (DES-PCI)). The long-term cost-effectiveness of these strategies is unknown. Between 2005 and 2007, 1800 patients with left main or 3-vessel coronary artery disease were randomized to CABG (n=897) or DES-PCI (n=903). Costs were assessed from a US perspective, and health state utilities were evaluated with the EuroQOL questionnaire. A patient-level microsimulation model based on the 5-year in-trial data was used to extrapolate costs, life expectancy, and quality-adjusted life expectancy over a lifetime horizon. Although initial procedural costs were $3415 per patient lower with CABG, total hospitalization costs were $10 036 per patient higher. Over the next 5 years, follow-up costs were higher with DES-PCI as a result of more frequent hospitalizations, revascularization procedures, and higher medication costs. Over a lifetime horizon, CABG remained more costly than DES-PCI, but the incremental cost-effectiveness ratio was favorable ($16 537 per quality-adjusted life-year gained) and remained <$20 000 per quality-adjusted life-year in most bootstrap replicates. Results were consistent across a wide range of assumptions about the long-term effect of CABG versus DES-PCI on events and costs. In patients with left main disease or a SYNTAX score ≤22, however, DES-PCI was economically dominant compared with CABG, although these findings were less certain. For most patients with 3-vessel or left main coronary artery disease, CABG is a clinically and economically attractive revascularization strategy compared with DES-PCI. However, among patients with less

  10. Meta-analysis of long-term outcomes of drug-eluting stent implantations for chronic total coronary occlusions.

    PubMed

    Ma, Jian; Yang, Weiwei; Singh, Manpreet; Peng, Tianqing; Fang, Ningyuan; Wei, Meng

    2011-01-01

    In the treatment of chronic total occlusions (CTOs), some uncertainty exists regarding the effect of drug-eluting stents (DESs) compared with the effects of bare mental stents (BMSs). We reviewed outcomes of DES vs. BMS implantation for CTO lesions, to evaluate the risk-benefit ratio of DES implantation. Relevant studies of long-term clinical outcomes or angiographic outcomes of both BMS and DES implantation were examined. The primary endpoint comprised major adverse cardiovascular events (MACEs), including all-cause deaths, myocardial infarctions (MIs), and target lesion revascularizations (TLRs). A fixed-effect model and random-effect model were used to analyze the pooling results. Ten studies were included according to the selection criteria. Eight were nonrandomized controlled trials, and two consisted of a randomized controlled comparison between DES and BMS implantation. No significant difference was evident for in-hospital MACE rates between the two groups (odds ratio [OR], 1.07; 95% confidence interval [CI], .53 to 2.13), but the long-term MACE rates in the DES group were significantly lower than in the BMS group (OR, .22; 95% CI, .13 to .38; P < .00001). The rates of stent restenosis and reocclusions were also significantly lower in the DES group (OR, .14; 95% CI, .09 to .20; and OR, .23; 95% CI, .12 to .41, respectively). Implantation of the DES improves long-term angiographic and clinical outcomes compared with BMS in the treatment of CTO lesions. Copyright © 2011 Elsevier Inc. All rights reserved.

  11. Effects of cobalt-chromium everolimus eluting stents or bare metal stent on fatal and non-fatal cardiovascular events: patient level meta-analysis

    PubMed Central

    Sabaté, Manel; Kaiser, Christoph; Brugaletta, Salvatore; de la Torre Hernandez, Jose Maria; Galatius, Soeren; Cequier, Angel; Eberli, Franz; de Belder, Adam; Serruys, Patrick W; Ferrante, Giuseppe

    2014-01-01

    Objectives To examine the safety and effectiveness of cobalt-chromium everolimus eluting stents compared with bare metal stents. Design Individual patient data meta-analysis of randomised controlled trials. Cox proportional regression models stratified by trial, containing random effects, were used to assess the impact of stent type on outcomes. Hazard ratios with 95% confidence interval for outcomes were reported. Data sources and study selection Medline, Embase, the Cochrane Central Register of Controlled Trials. Randomised controlled trials that compared cobalt-chromium everolimus eluting stents with bare metal stents were selected. The principal investigators whose trials met the inclusion criteria provided data for individual patients. Primary outcomes The primary outcome was cardiac mortality. Secondary endpoints were myocardial infarction, definite stent thrombosis, definite or probable stent thrombosis, target vessel revascularisation, and all cause death. Results The search yielded five randomised controlled trials, comprising 4896 participants. Compared with patients receiving bare metal stents, participants receiving cobalt-chromium everolimus eluting stents had a significant reduction of cardiac mortality (hazard ratio 0.67, 95% confidence interval 0.49 to 0.91; P=0.01), myocardial infarction (0.71, 0.55 to 0.92; P=0.01), definite stent thrombosis (0.41, 0.22 to 0.76; P=0.005), definite or probable stent thrombosis (0.48, 0.31 to 0.73; P<0.001), and target vessel revascularisation (0.29, 0.20 to 0.41; P<0.001) at a median follow-up of 720 days. There was no significant difference in all cause death between groups (0.83, 0.65 to 1.06; P=0.14). Findings remained unchanged at multivariable regression after adjustment for the acuity of clinical syndrome (for instance, acute coronary syndrome v stable coronary artery disease), diabetes mellitus, female sex, use of glycoprotein IIb/IIIa inhibitors, and up to one year v longer duration treatment with dual

  12. Effects of cobalt-chromium everolimus eluting stents or bare metal stent on fatal and non-fatal cardiovascular events: patient level meta-analysis.

    PubMed

    Valgimigli, Marco; Sabaté, Manel; Kaiser, Christoph; Brugaletta, Salvatore; de la Torre Hernandez, Jose Maria; Galatius, Soeren; Cequier, Angel; Eberli, Franz; de Belder, Adam; Serruys, Patrick W; Ferrante, Giuseppe

    2014-11-04

    To examine the safety and effectiveness of cobalt-chromium everolimus eluting stents compared with bare metal stents. Individual patient data meta-analysis of randomised controlled trials. Cox proportional regression models stratified by trial, containing random effects, were used to assess the impact of stent type on outcomes. Hazard ratios with 95% confidence interval for outcomes were reported. Medline, Embase, the Cochrane Central Register of Controlled Trials. Randomised controlled trials that compared cobalt-chromium everolimus eluting stents with bare metal stents were selected. The principal investigators whose trials met the inclusion criteria provided data for individual patients. The primary outcome was cardiac mortality. Secondary endpoints were myocardial infarction, definite stent thrombosis, definite or probable stent thrombosis, target vessel revascularisation, and all cause death. The search yielded five randomised controlled trials, comprising 4896 participants. Compared with patients receiving bare metal stents, participants receiving cobalt-chromium everolimus eluting stents had a significant reduction of cardiac mortality (hazard ratio 0.67, 95% confidence interval 0.49 to 0.91; P=0.01), myocardial infarction (0.71, 0.55 to 0.92; P=0.01), definite stent thrombosis (0.41, 0.22 to 0.76; P=0.005), definite or probable stent thrombosis (0.48, 0.31 to 0.73; P<0.001), and target vessel revascularisation (0.29, 0.20 to 0.41; P<0.001) at a median follow-up of 720 days. There was no significant difference in all cause death between groups (0.83, 0.65 to 1.06; P=0.14). Findings remained unchanged at multivariable regression after adjustment for the acuity of clinical syndrome (for instance, acute coronary syndrome v stable coronary artery disease), diabetes mellitus, female sex, use of glycoprotein IIb/IIIa inhibitors, and up to one year v longer duration treatment with dual antiplatelets. This meta-analysis offers evidence that compared with bare metal

  13. [Experience with the use of the bio-active stent coated with titanium nitric oxide compared with zotarolimus-eluting stent: experience of a unit medical high specialty].

    PubMed

    Garcia-Gutierrez, Juan C; Palacios-Rodríguez, Juan M; Cordova-Correa, Horacio G; Becerra-Laguna, Carlos A; López-López, Hugo A; Salinas Aragón, Miguel A; García-Bonilla, Jorge

    2016-01-01

    The use of coronary stents in coronary angioplasty has evolved dramatically in its design, type materials, polymers, and a variety of drugs, the use of coronary stents covered nitric oxide have shown satisfactory results in practice, however compared to the results reported drug-eluting stents, there is little information. The aim of this study was to compare clinical outcomes of a stainless steel stent Bioactive nitric oxide coated titanium (BAS) and a drug-eluting stent zotarolimus (DES) in daily clinical practice. A retrospective, analytical, descriptive and comparative study aimed at evaluating the safety and efficacy of two devices with different characteristics in our population. The primary endpoints were: death, acute infarction (AMI), and re intervention injury Treated (RLT). A total of 759 patients were included in the study which was performed angioplasty to a single vessel. Were divided into two arms 382 with DES and 377 patients with BAS, the one year follow up was carried in 95%. After this follow-up period, primary points (cardiovascular death, myocardial infarction, TLR and stent thrombosis) for arm DES vs BAS; 9.5% vs 8.5% P=NS but with shorter periods of dual antiplatelet therapy for arm BAS 6.9±4.1 vs 11.1±2.5 months DES P=.0001. The results were independent of the clinical syndrome of presentation. After one year of follow no statistically significant difference in major clinical events, there was a trend in favour of BAS vs SM with respect to revascularization of the target lesion without reaching statistical significance. Copyright © 2015 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  14. Two-Year Clinical Outcomes of Newer-Generation Drug-Eluting Stent Implantation Following Rotational Atherectomy for Heavily Calcified Lesions.

    PubMed

    Jinnouchi, Hiroyuki; Kuramitsu, Shoichi; Shinozaki, Tomohiro; Kobayashi, Yohei; Hiromasa, Takashi; Morinaga, Takashi; Mazaki, Toru; Sakakura, Kenichi; Soga, Yoshimitsu; Hyodo, Makoto; Shirai, Shinichi; Ando, Kenji

    2015-01-01

    Clinical outcomes of implantation of the newer-generation drug-eluting stent (DES) following rotational atherectomy for heavily calcified lesions remain unclear in the real-world setting. We enrolled 252 consecutive patients (273 lesions) treated with newer-generation DES following rotational atherectomy. The primary endpoint was the cumulative 2-year incidence of major adverse cardiovascular events (MACE), defined as cardiac death, myocardial infarction, clinically-driven target lesion revascularization, and definite stent thrombosis. Complete clinical follow-up information at 2-year was obtained for all patients. The mean age was 73.2±9.0 years and 155 patients (61.5%) were male. Cumulative 2-year incidence of MACE (cardiac death, myocardial infarction, clinically-driven target lesion revascularization and definite stent thrombosis) was 20.3% (7.0%, 2.1%, 18.1% and 2.1%, respectively). Predictors of MACE were presenting with acute coronary syndrome (hazard ratio [HR]: 3.80, 95% confidence interval [CI]: 1.29-11.2, P=0.02), hemodialysis (HR: 1.93, 95% CI: 1.04-3.56, P=0.04) and previous coronary artery bypass graft (HR: 2.26, 95% CI: 1.02-5.00, P=0.045). PCI for calcified lesions requiring rotational atherectomy is still challenging even in the era of newer-generation DES.

  15. Temporary placement of a paclitaxel or rapamycin-eluting stent is effective to reduce stenting induced inflammatory reaction and scaring in benign cardia stricture models.

    PubMed

    Wang, Lin; Zhu, Yue-Qi; Cheng, Ying-Sheng; Cui, Wen-Guo; Chen, Ni-Wei

    2014-12-01

    To investigate whether temporary placement of a paclitaxel or rapamycin eluting stent is more effective to reduce stenting induced inflammatory reaction and scaring than a bared stent in benign cardia stricture models. Eighty dog models of stricture were randomly divided into a control group (CG, n=20, no stent insertion), a bare stent group (BSG, n=20), a paclitaxel eluting (Pacl-ESG, n=20) and a rapamycin eluting stent group (Rapa-ESG, n=20), with one-week stent retention. Lower-oesophageal-sphincter pressure (LOSP), 5-minute barium height (5-mBH) and cardia diameter were assessed before, immediately after the procedure, and regularly for 6 months. Five dogs in each group were euthanized for histological examination at each follow-up assessment. Stent insertion was well tolerated, with similar migration rates in three groups. At 6 months, LOSP and 5-mBH improved in Pacl-ESG and Rapa-ESG compared to BSG (p<0.05), with no difference between Pacl-ESG and Rapa-ESG (p>0.05). Cardia kept more patency in the Pacl-ESG and Rapa-ESG than in BSG (p<0.05). Reduced peak inflammatory reactions and scarring occurred in the Pacl-ESG and Rapa-ESG compared to BSG (p<0.05), with a similar outcome in the Pacl-ESG and Rapa-ESG (p>0.05). Paclitaxel or rapamycin-eluting stents insertion led to better outcomes than bare stents in benign cardia stricture models.

  16. Biological effect on drug distribution and vascular healing via paclitaxel-coated balloon technology in drug eluting stent restenosis swine model.

    PubMed

    Li, Yan; Tellez, Armando; Rousselle, Serge D; Dillon, Krista N; Garza, Javier A; Barry, Chris; Granada, Juan F

    2016-07-01

    To evaluate the biological effect of a paclitaxel-coated balloon (PCB) technology on vascular drug distribution and healing in drug eluting stent restenosis (DES-ISR) swine model. The mechanism of action and healing response via PCB technology in DES-ISR is not completely understood. A total of 27 bare metal stents were implanted in coronary arteries and 30 days later the in-stent restenosis was treated with PCB. Treated segments were harvested at 1 hr, 14 days and 30 days post treatment for the pharmacokinetic analysis. In addition, 24 DES were implanted in coronary arteries for 30 days, then all DES-ISRs were treated with either PCB (n = 12) or uncoated balloon (n = 12). At day 60, vessels were harvested for histology following angiography and optical coherence tomography (OCT). The paclitaxel level in neointimal tissue was about 18 times higher (P = 0.0004) at 1 hr Cmax , and retained about five times higher (P = 0.008) at day 60 than that in vessel wall. A homogenous distribution of paclitaxel in ISR was demonstrated by using fluorescently labeled paclitaxel. Notably, in DES-ISR, both termination OCT and quantitative coronary angioplasty showed a significant neointimal reduction and less late lumen loss (P = 0.05 and P = 0.03, respectively) post PCB versus post uncoated balloon. The PES-ISR + PCB group displayed higher levels of peri-strut inflammation and fibrin scores compared to the -limus DES-ISR + PCB group. In ISR, paclitaxel is primarily deposited in neointimal tissue and effectively retained over time following PCB use. Despite the presence of metallic struts, a uniform distribution was characterized. PCB demonstrated an equivalent biological effect in DES-ISR without significantly increasing inflammation. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  17. Biological effect on drug distribution and vascular healing via paclitaxel‐coated balloon technology in drug eluting stent restenosis swine model

    PubMed Central

    Li, Yan; Tellez, Armando; Rousselle, Serge D.; Dillon, Krista N.; Garza, Javier A.; Barry, Chris

    2015-01-01

    Objectives To evaluate the biological effect of a paclitaxel‐coated balloon (PCB) technology on vascular drug distribution and healing in drug eluting stent restenosis (DES‐ISR) swine model. Background The mechanism of action and healing response via PCB technology in DES‐ISR is not completely understood. Methods A total of 27 bare metal stents were implanted in coronary arteries and 30 days later the in‐stent restenosis was treated with PCB. Treated segments were harvested at 1 hr, 14 days and 30 days post treatment for the pharmacokinetic analysis. In addition, 24 DES were implanted in coronary arteries for 30 days, then all DES‐ISRs were treated with either PCB (n = 12) or uncoated balloon (n = 12). At day 60, vessels were harvested for histology following angiography and optical coherence tomography (OCT). Results The paclitaxel level in neointimal tissue was about 18 times higher (P = 0.0004) at 1 hr C max, and retained about five times higher (P = 0.008) at day 60 than that in vessel wall. A homogenous distribution of paclitaxel in ISR was demonstrated by using fluorescently labeled paclitaxel. Notably, in DES‐ISR, both termination OCT and quantitative coronary angioplasty showed a significant neointimal reduction and less late lumen loss (P = 0.05 and P = 0.03, respectively) post PCB versus post uncoated balloon. The PES‐ISR + PCB group displayed higher levels of peri‐strut inflammation and fibrin scores compared to the ‐limus DES‐ISR + PCB group. Conclusions In ISR, paclitaxel is primarily deposited in neointimal tissue and effectively retained over time following PCB use. Despite the presence of metallic struts, a uniform distribution was characterized. PCB demonstrated an equivalent biological effect in DES‐ISR without significantly increasing inflammation. © 2015 Wiley Periodicals, Inc. PMID:26613810

  18. Improved outcomes of elderly patients treated with drug-eluting versus bare metal stents in large coronary arteries: results from the BAsel Stent Kosten-Effektivitäts Trial PROspective Validation Examination randomized trial.

    PubMed

    Kurz, David J; Bernheim, Alain M; Tüller, David; Zbinden, Rainer; Jeger, Raban; Kaiser, Christoph; Galatius, Soeren; Hansen, Kim W; Alber, Hannes; Pfisterer, Matthias; Eberli, Franz R

    2015-10-01

    Drug-eluting stents (DES) improve outcomes in elderly patients with small coronary artery disease compared with bare-metal stents (BMS), but randomized data in elderly patients in need of large coronary stents are not available. Planned secondary analysis of patients ≥75 years recruited to the "BASKET-PROVE" trial, in which 2,314 patients undergoing percutaneous coronary intervention for large (≥3.0 mm) native vessel disease were randomized 2:1 to DES (everolimus- vs sirolimus-eluting stents 1:1) versus BMS. All patients received 12 months of dual antiplatelet therapy. The primary end point was a composite of cardiac death or nonfatal myocardial infarction at 2 years. Comparison of DES versus BMS among 405 patients ≥75 years showed significantly lower rates of the primary end point for DES (5.0% vs 11.6%; hazard ration (HR) 0.64 [0.44-0.91]; P = .014). Rates of nonfatal myocardial infarction (1.2% vs 5.5%, hazard ration (HR) 0.44 [0.21-0.83]; P = .009), all-cause death (7.4% vs 14.4%; HR 0.7 [0.51-0.95]; P = .02), and target vessel revascularization (TVR) (2.3% vs 6.2%; HR 0.59 [0.34-0.99]; P = .046) were also lower, whereas stent thrombosis and bleeding rates were similar. In contrast, among patients <75 years (n = 1,909), the only significant benefit of DES was a reduced rate of TVR (4.0% vs 8.7%, HR 0.66 [0.55-0.80]; P < .0001). In patients ≥75 years requiring large (≥3.0 mm) coronary stents, use of DES was beneficial compared with BMS and reduced the rate of ischemic events, mortality, and TVR. These data suggest that DES should be preferred over BMS in elderly patients. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. One-year clinical outcomes of ultra long apollo polymer-based Paclitaxel-eluting stents in patients with complex, long coronary artery lesions.

    PubMed

    Salarifar, Mojtaba; Kassaian, Seyed Ebrahim; Alidoosti, Mohammad; Haji-Zeinali, Ali Mohammad; Poorhoseini, Hamid Reza; Nematipour, Ebrahim; Amirzadegan, Alireza; Saroukhani, Sepideh

    2011-01-01

    For all the wealth of research comparing the efficacy of the different types of the drug-eluting stent (DES) such as sirolimus-, paclitaxel-, and zotarolimus-eluting stents, there is still a dearth of data on the different brands of each DES type. We aimed to investigate the one-year clinical outcomes, including major adverse cardiac events (MACE), of the use of the ultra long Apollo paclitaxel-eluting stent in patients with long atherosclerotic coronary artery lesions. According to a retrospective review of the Tehran Heart Center Registry of Interventional Cardiology, a single-center nonrandomized computerized data registry in which all adult patients who undergo single or multi-vessel percutaneous coronary intervention (PCI) are enrolled without any specific exclusion criteria, the mixed use of long Apollo paclitaxel-eluting stents and other types of the DES as well as myocardial infarction within forty-eight hours prior to the procedure was excluded. In total, 122 patients were enrolled in the study, and their baseline clinical, angiographic, and procedural characteristics were obtained. In addition, the patients' follow-up data and, most importantly, MACE during a one-year period after intervention were recorded. The mean follow-up duration was 14.1 ± 3.8 months. The one-year clinical follow-up data were obtained in 95.9 % of all the patients. The incidence of MACE was 5.7% during the entire study period. There was 1 death, which occurred during the initial days after PCI. The incidence of non-fatal myocardial infarction was 2.5% (3 cases), including one patient who underwent target vessel revascularization seven months later. Also, 3 patients with single-vessel disease and in-stent restenosis underwent coronary artery bypass grafting between five to ten months later. Our results showed that the Apollo paclitaxel-eluting stent might be regarded as a safe and effective treatment for long coronary lesions.

  20. Titanium-nitride-oxide-coated coronary stents: insights from the available evidence.

    PubMed

    Karjalainen, Pasi P; Nammas, Wail

    2017-06-01

    Coating of stent surface with a biocompatible material is suggested to improve stent safety profile. A proprietary process was developed to coat titanium-nitride-oxide on the stent surface, based on plasma technology that uses the nano-synthesis of gas and metal. Preclinical in vitro and in vivo investigation confirmed blood compatibility of titanium (nitride-) oxide films. Titanium-nitride-oxide-coated stents demonstrated a better angiographic outcome, compared with bare-metal stents at mid-term follow-up; however, they failed to achieve non-inferiority for angiographic outcome versus second-generation drug-eluting stents. Observational studies showed adequate clinical outcome at mid-term follow-up. Non-randomized studies showed an outcome of titanium-nitride-oxide-coated stents comparable to - or better than - first-generation drug-eluting stents at long-term follow-up. Two randomized controlled trials demonstrated comparable efficacy outcome, and a better safety outcome of titanium-nitride-oxide-coated stents versus drug-eluting stents at long-term follow-up. Evaluation by optical coherence tomography at mid-term follow-up revealed better neointimal strut coverage associated with titanium-nitride-oxide-coated stents versus drug-eluting stents; yet, neointimal hyperplasia thickness was greater. Key messages Stents coated with titanium-nitride-oxide demonstrated biocompatibility in preclinical studies: they inhibit platelet and fibrin deposition, and reduce neointimal growth. In observational and non-randomized studies, titanium-nitride-oxide-coated stents were associated with adequate safety and efficacy outcome. In randomized trials of patients with acute coronary syndrome, titanium-nitride-oxide-coated stents were associated with a better safety outcome, compared with drug-eluting stents; efficacy outcome was comparable.

  1. Third generation drug eluting stent (DES) with biodegradable polymer in diabetic patients: 5 years follow-up.

    PubMed

    Wiemer, Marcus; Stoikovic, Sinisa; Samol, Alexander; Dimitriadis, Zisis; Ruiz-Nodar, Juan M; Birkemeyer, Ralf; Monsegu, Jacques; Finet, Gérard; Hildick-Smith, David; Tresukosol, Damras; Novo, Enrique Garcia; Koolen, Jacques J; Barbato, Emanuele; Danzi, Gian Battista

    2017-02-10

    To report the long-term safety and efficacy data of a third generation drug eluting stent (DES) with biodegradable polymer in the complex patient population of diabetes mellitus after a follow-up period of 5 years. After percutaneous coronary intervention patients with diabetes mellitus are under higher risk of death, restenosis and stent thrombosis (ST) compared to non-diabetic patients. In 126 centers worldwide 3067 patients were enrolled in the NOBORI 2 registry, 888 patients suffered from diabetes mellitus (DM), 213 of them (14%) being insulin dependent (IDDM). Five years follow-up has been completed in this study. At 5 years, 89.3% of the patients were available for follow-up. The reported target lesion failure (TLF) rates at 5 years were 12.39% in DM group and 7.34% in non-DM group; (p < 0.0001). In the DM group, the TLF rate in patients with IDDM was significantly higher than in the non-IDDM subgroup (17.84 vs. 10.67%; p < 0.01). The rate of ST at 5 years was not different among diabetic versus non-diabetic patients or IDDM versus NIDDM. Only 10 (<0.4%) very late stent thrombotic events beyond 12 months occurred. The Nobori DES performed well in patients with DM. As expected patients with DM, particularly those with IDDM, had worse outcomes. However, the very low rate of very late stent thrombosis in IDDM patients might have significant clinical value in the treatment of these patients. Clinical trial registration ISRCTN81649913; http://www.controlled-trials.com/isrctn/search.html?srch=81649913&sort=3&dir=desc&max=10.

  2. In-Stent Restenosis of Drug-Eluting Stents Compared With a Matched Group of Patients With De Novo Coronary Artery Stenosis.

    PubMed

    Buchanan, Kyle D; Torguson, Rebecca; Rogers, Toby; Xu, Linzhi; Gai, Jiaxiang; Ben-Dor, Itsik; Suddath, William O; Satler, Lowell F; Waksman, Ron

    2018-03-13

    Drug-eluting stents (DES) significantly reduced the incidence of in-stent restenosis (ISR). However, ISR still exists in the contemporary DES era. Previously deemed to be a benign process, ISR leads to complex presentation and intervention. This study aimed to compare the presentation and outcome of DES-ISR versus de novo lesions. We performed a retrospective analysis of 11,666 patients receiving percutaneous coronary intervention from 2003 to 2017 and divided them into 2 groups by de novo stenosis and ISR. They were matched based on common cardiovascular risk factors at a 4:1 ratio, respectively. After matching, a total of 1,888 patients with 3,126 de novo lesions and 472 patients with 508 ISR lesions were analyzed. Patients with ISR presented more often with unstable angina (61% vs 45%, p <0.001) and less often with myocardial infarction (6% vs 14%, p <0.001). One-year composite major adverse cardiovascular event, defined as death, Q-wave myocardial infarction, and target vessel revascularization, was 10% in the de novo group and 17% in the ISR group (hazard ratio 1.98, 95% confidential interval 1.58 to 2.46, p <0.001). After adjusting for myocardial infarction presentation, hazard ratio of major adverse cardiovascular events was still higher for the ISR group at 1 year (2.03, 95% confidential interval 1.62 to 2.55, p <0.001). ISR of DES remains a therapeutic challenge and leads to complex presentation and worse outcomes compared with matched de novo patients. These data show that DES-ISR demands better appreciation and prevention with more precise stent technique and should motivate the continued development of fully bioresorbable scaffolds. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. Long-term efficacy and safety of biodegradable-polymer biolimus-eluting stents: main results of the Basel Stent Kosten-Effektivitäts Trial-PROspective Validation Examination II (BASKET-PROVE II), a randomized, controlled noninferiority 2-year outcome trial.

    PubMed

    Kaiser, Christoph; Galatius, Soeren; Jeger, Raban; Gilgen, Nicole; Skov Jensen, Jan; Naber, Christoph; Alber, Hannes; Wanitschek, Maria; Eberli, Franz; Kurz, David J; Pedrazzini, Giovanni; Moccetti, Tiziano; Rickli, Hans; Weilenmann, Daniel; Vuillomenet, André; Steiner, Martin; Von Felten, Stefanie; Vogt, Deborah R; Wadt Hansen, Kim; Rickenbacher, Peter; Conen, David; Müller, Christian; Buser, Peter; Hoffmann, Andreas; Pfisterer, Matthias

    2015-01-06

    Biodegradable-polymer drug-eluting stents (BP-DES) were developed to be as effective as second-generation durable-polymer drug-eluting stents (DP-DES) and as safe >1 year as bare-metal stents (BMS). Thus, very late stent thrombosis (VLST) attributable to durable polymers should no longer appear. To address these early and late aspects, 2291 patients presenting with acute or stable coronary disease needing stents ≥3.0 mm in diameter between April 2010 and May 2012 were randomly assigned to biolimus-A9-eluting BP-DES, second-generation everolimus-eluting DP-DES, or thin-strut silicon-carbide-coated BMS in 8 European centers. All patients were treated with aspirin and risk-adjusted doses of prasugrel. The primary end point was combined cardiac death, myocardial infarction, and clinically indicated target-vessel revascularization within 2 years. The combined secondary safety end point was a composite of VLST, myocardial infarction, and cardiac death. The cumulative incidence of the primary end point was 7.6% with BP-DES, 6.8% with DP-DES, and 12.7% with BMS. By intention-to-treat BP-DES were noninferior (predefined margin, 3.80%) compared with DP-DES (absolute risk difference, 0.78%; -1.93% to 3.50%; P for noninferiority 0.042; per protocol P=0.09) and superior to BMS (absolute risk difference, -5.16; -8.32 to -2.01; P=0.0011). The 3 stent groups did not differ in the combined safety end point, with no decrease in events >1 year, particularly VLST with BP-DES. In large vessel stenting, BP-DES appeared barely noninferior compared with DP-DES and more effective than thin-strut BMS, but without evidence for better safety nor lower VLST rates >1 year. Findings challenge the concept that durable polymers are key in VLST formation. http://www.clinicaltrials.gov. Unique identifier: NCT01166685. © 2014 American Heart Association, Inc.

  4. Determining clinical benefits of drug-eluting coronary stents according to the population risk profile: a meta-regression from 31 randomized trials.

    PubMed

    Moreno, Raul; Martin-Reyes, Roberto; Jimenez-Valero, Santiago; Sanchez-Recalde, Angel; Galeote, Guillermo; Calvo, Luis; Plaza, Ignacio; Lopez-Sendon, Jose-Luis

    2011-04-01

    The use of drug-eluting stents (DES) in unfavourable patients has been associated with higher rates of clinical complications and stent thrombosis, and because of that concerns about the use of DES in high-risk settings have been raised. This study sought to demonstrate that the clinical benefit of DES increases as the risk profile of the patients increases. A meta-regression analysis from 31 randomized trials that compared DES and bare-metal stents, including overall 12,035 patients, was performed. The relationship between the clinical benefit of using DES (number of patients to treat [NNT] to prevent one episode of target lesion revascularization [TLR]), and the risk profile of the population (rate of TLR in patients allocated to bare-metal stents) in each trial was evaluated. The clinical benefit of DES increased as the risk profile of each study population increased: NNT for TLR=31.1-1.2 (TLR for bare-metal stents); p<0.001. The use of DES was safe regardless of the risk profile of each study population, since the effect of DES in mortality, myocardial infarction, and stent thrombosis, was not adversely affected by the risk profile of each study population (95% confidence interval for β value 0.09 to 0.11, -0.12 to 0.19, and -0.03 to-0.15 for mortality, myocardial infarction, and stent thrombosis, respectively). The clinical benefit of DES increases as the risk profile of the patients increases, without affecting safety. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  5. A comparison of two brands of clopidogrel in patients with drug-eluting stent implantation.

    PubMed

    Park, Yae Min; Ahn, Taehoon; Lee, Kyounghoon; Shin, Kwen-Chul; Jung, Eul Sik; Shin, Dong Su; Kim, Myeong Gun; Kang, Woong Chol; Han, Seung Hwan; Choi, In Suck; Shin, Eak Kyun

    2012-07-01

    Although generic clopidogrel is widely used, clinical efficacy and safety between generic and original clopidogrel had not been well evaluated. The aim of this study was to evaluate the clinical outcomes of 2 oral formulations of clopidogrel 75 mg tablets in patients with coronary artery disease (CAD) undergoing drug-eluting stent (DES) implantation. Between July 2006 and February 2009, 428 patients that underwent implantation with DES for CAD and completed >1 year of clinical follow-up were enrolled in this study. Patients were divided into the following 2 groups based on treatment formulation, Platless® (test formulation, n=211) or Plavix® (reference formulation, n=217). The incidence of 1-year major adverse cardiovascular and cerebrovascular event (MACCE) and stent thrombosis (ST) were retrospectively reviewed. The baseline demographic and procedural characteristics were not significantly different between two treatment groups. The incidence of 1-year MACCEs was 8.5% {19/211, 2 deaths, 4 myocardial infarctions (MIs), 2 strokes, and 11 target vessel revascularizations (TVRs)} in Platless® group vs. 7.4% (16/217, 4 deaths, 1 MI, 2 strokes, and 9 TVRs) in Plavix® group (p=0.66). The incidence of 1-year ST was 0.5% (1 definite and subacute ST) in Platless® group vs. 0% in Plavix® group (p=0.49). In this study, the 2 tablet preparations of clopidogrel showed similar rates of MACCEs, but additional prospective randomized studies with pharmacodynamics and platelet reactivity are needed to conclude whether generic clopidgrel may replace original clopidogrel.

  6. Percutaneous Coronary Intervention of Left Main Disease: Pre- and Post-EXCEL (Evaluation of XIENCE Everolimus Eluting Stent Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization) and NOBLE (Nordic-Baltic-British Left Main Revascularization Study) Era.

    PubMed

    Park, Duk-Woo; Park, Seung-Jung

    2017-06-01

    For nearly half a century, coronary artery bypass grafting has been the standard treatment for patients with obstructive left main coronary artery (LMCA) disease. However, there has been considerable evolution in the field of percutaneous coronary intervention, and especially, percutaneous coronary intervention for LMCA disease has been rapidly expanded with adoption of drug-eluting stents. Some, but not all randomized trials, have shown that percutaneous coronary intervention with drug-eluting stents might be a suitable alternative for selected patients with LMCA disease instead of bypass surgery. However, none of previous trials involving early-generation drug-eluting stents was sufficiently powered and comparative trials using contemporary drug-eluting stents were limited. Recently, primary results of 2 new trials of EXCEL (Evaluation of XIENCE Everolimus Eluting Stent Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization) and NOBLE (Nordic-Baltic-British Left Main Revascularization Study) were reported. However, these trials showed conflicting results, which might pose uncertainty on the optimal revascularization strategy for LMCA disease. In this article, with the incorporation of a key review on evolution of LMCA treatment, we summarize the similarity or disparity of the EXCEL and NOBLE trials, focus on how they relate to previous trials in the field, and finally speculate on how the treatment strategy may be changed or recommended for LMCA treatment. © 2017 American Heart Association, Inc.

  7. Integrity(®) bare-metal coronary stent-induced platelet and endothelial cell activation results in a higher risk of restenosis compared to Xience(®) everolimus-eluting stents in stable angina patients.

    PubMed

    Szük, Tibor; Fejes, Zsolt; Debreceni, Ildikó Beke; Kerényi, Adrienne; Édes, István; Kappelmayer, János; Nagy, Béla

    2016-07-01

    Drug-eluting stenting (DES) has become a reliable tool for coronary stenting; however, its direct effects on platelet and endothelium function differ from those of bare-metal stenting (BMS). This study involved a periprocedural analysis of various biomarkers of cellular activation after elective DES (Xience(®), Abbott Vascular, Santa Clara, CA, USA) or BMS (Integrity(®), Medtronic, Minneapolis, MI, USA). Forty-nine stable angina patients were recruited: 28 underwent BMS, and 21 received everolimus-eluting stents. Samples were collected (i) prior to stenting, (ii) at 24 hours after procedure, and (iii) after 1 month of dual antiplatelet therapy. Platelet activation was analyzed by surface P-selectin positivity in parallel with plasma levels of soluble P-selectin, CD40L and platelet-derived growth factor (PDGF). Endothelial cell (EC) activation was detected by measuring markers of early (von Willebrand factor) and delayed response (VCAM-1, ICAM-1, E-selectin). Patients were followed for 6 months for the occurrence of restenosis or stent thrombosis. Increased platelet activation was sustained regardless of stent type or antiplatelet medication. Concentrations of most EC markers were more elevated after BMS than after DES. No stent thrombosis was seen, but six BMS subjects displayed restenosis with significantly higher sCD40L (779 [397-899] vs. 381 [229-498] pg/mL; p = 0.032) and sICAM-1 (222 [181-272] vs. 162 [153-223] ng/mL; p = 0.046) levels than in those without complication, while DES patients exhibited significantly decreased PDGF (572 [428-626] vs. 244 [228-311] pg/mL; p = 0.004) after 1 month. Nonresponsiveness to antiplatelet drugs did not influence these changes. In conclusion, the degree of platelet and EC activation suggests that Xience(®) DES may be regarded a safer coronary intervention than Integrity(®) BMS, with a lower risk of in-stent restenosis.

  8. Natural history of optical coherence tomography-detected non-flow-limiting edge dissections following drug-eluting stent implantation.

    PubMed

    Radu, Maria D; Räber, Lorenz; Heo, Jungho; Gogas, Bill D; Jørgensen, Erik; Kelbæk, Henning; Muramatsu, Takashi; Farooq, Vasim; Helqvist, Steffen; Garcia-Garcia, Hector M; Windecker, Stephan; Saunamäki, Kari; Serruys, Patrick W

    2014-01-22

    Angiographic evidence of edge dissections has been associated with a risk of early stent thrombosis. Optical coherence tomography (OCT) is a high-resolution technology detecting a greater number of edge dissections--particularly non-flow-limiting--compared to angiography. Their natural history and clinical implications remain unclear. The objectives of the present study were to assess the morphology, healing response, and clinical outcomes of OCT-detected edge dissections using serial OCT imaging at baseline and at one year following drug-eluting stent (DES) implantation. Edge dissections were defined as disruptions of the luminal surface in the 5 mm segments proximal and distal to the stent, and categorised as flaps, cavities, double-lumen dissections or fissures. Qualitative and quantitative OCT analyses were performed every 0.5 mm at baseline and one year, and clinical outcomes were assessed. Sixty-three lesions (57 patients) were studied with OCT at baseline and one-year follow-up. Twenty-two non-flow-limiting edge dissections in 21 lesions (20 patients) were identified by OCT; only two (9%) were angiographically visible. Flaps were found in 96% of cases. The median longitudinal dissection length was 2.9 mm (interquartile range [IQR] 1.6-4.2 mm), whereas the circumferential and axial extensions amounted to 1.2 mm (IQR: 0.9-1.7 mm) and 0.6 mm (IQR: 0.4-0.7 mm), respectively. Dissections extended into the media and adventitia in seven (33%) and four (20%) cases, respectively. Eighteen (82%) OCT-detected edge dissections were also evaluated with intravascular ultrasound which identified nine (50%) of these OCT-detected dissections. No stent thrombosis or target lesion revascularisation occurred up to one year. At follow-up, 20 (90%) edge dissections were completely healed on OCT. The two cases exhibiting persistent dissection had the longest flaps (2.81 mm and 2.42 mm) at baseline. OCT-detected edge dissections which are angiographically silent in the majority of

  9. Advantages of novel BioMimeTM Sirolimus Eluting Coronary Stent system. Moving towards biomimicry.

    PubMed

    Upendra, K; Sanjeev, B

    2012-02-01

    Since the first reported use of percutaneous transluminal coronary angioplasty (PTCA), advancements in interventional cardiology arena have been fast paced. Within the last ten years, these developments have been exponential. Developers & clinicians are fast adapting from the learning curve awarded by the time course of DES evolution. In that light BioMimeTM Sirolimus Eluting Coronary Stent comes as a fresh thought in taking stents towards a biomimicry concept. The stent is built on an ultra-low strut thickness (65 µm) cobalt chromium stent platform, using an intelligent hybrid of close and open cells allowing for morphology mediated expansion, employs a well known anti-proliferative - Sirolimus that elutes from a biodegradable co-polymer formulation in 30 days and ensures high coating integrity and low coating thickness of 2 µm. The resultant stent demonstrates almost 100% endothelialization at 30 days in preclinical model and zero percent MACE >18 months in the primary efficacy and safety clinical study.

  10. Evaluation of biodegradable paclitaxel-eluting nanofibre-covered metal stents for the treatment of benign cardia stricture in an experimental model.

    PubMed

    Zhu, Y-Q; Cui, W-G; Cheng, Y-S; Chang, J; Chen, N-W; Yan, L

    2013-05-01

    Benign strictures at the cardia are troublesome for patients and often require repeated endoscopic treatments. Paclitaxel can reduce fibrosis. This study evaluated a biodegradable paclitaxel-eluting nanofibre-covered metal stent for the treatment of benign cardia stricture in vitro and in vivo. Drug release was investigated in vitro at pH 7·4 and 4·0. Eighty dogs were divided randomly into four groups (each n = 20): controls (no stent), bare stent (retained for 1 week), and two drug-eluting stent (DES) groups with retention for either 1 week (DES-1w) or 4 weeks (DES-4w). Lower oesophageal sphincter pressure (LOSP) and 5-min barium height (5-mBH) were assessed before, immediately after stent deployment, at 1 week, and 1, 3 and 6 months later. Five dogs in each group were killed for histological examination at each follow-up point. Stent migration rates were similar (0 bare stent versus 2 DES; P = 0·548). The percentage and amount of paclitaxel released in vitro was higher at pH 4·0 than at pH 7·4. After 6 months, LOSP and 5-mBH were both improved in the DES-1w (P = 0·004 and P = 0·049) and DES-4w (both P < 0·001) groups compared with the bare-stent group, with better relief when the stent was retained for 4 weeks (P = 0·004 and P = 0·007). The DES was associated with a reduced peak inflammatory reaction and less scar formation compared with bare stents, especially when inserted for 4 weeks. The DES was more effective for the treatment of benign cardia stricture than bare stents in a canine model. Retention of the DES for 4 weeks led to a better clinical and pathological outcome than 1 week. © 2013 British Journal of Surgery Society Ltd. Published by John Wiley & Sons Ltd.

  11. Cost-effectiveness of percutaneous coronary intervention with cobalt-chromium everolimus eluting stents versus bare metal stents: Results from a patient level meta-analysis of randomized trials.

    PubMed

    Ferko, Nicole; Ferrante, Giuseppe; Hasegawa, James T; Schikorr, Tanya; Soleas, Ireena M; Hernandez, John B; Sabaté, Manel; Kaiser, Christoph; Brugaletta, Salvatore; de la Torre Hernandez, Jose Maria; Galatius, Soeren; Cequier, Angel; Eberli, Franz; de Belder, Adam; Serruys, Patrick W; Valgimigli, Marco

    2017-05-01

    Second-generation drug eluting stents (DES) may reduce costs and improve clinical outcomes compared to first-generation DES with improved cost-effectiveness when compared to bare metal stents (BMS). We aimed to conduct an economic evaluation of a cobalt-chromium everolimus eluting stent (Co-Cr EES) compared with BMS in percutaneous coronary intervention (PCI). To conduct a cost-effectiveness analysis (CEA) of a cobalt-chromium everolimus eluting stent (Co-Cr EES) versus BMS in PCI. A Markov state transition model with a 2-year time horizon was applied from a US Medicare setting with patients undergoing PCI with Co-Cr EES or BMS. Baseline characteristics, treatment effects, and safety measures were taken from a patient level meta-analysis of 5 RCTs (n = 4,896). The base-case analysis evaluated stent-related outcomes; a secondary analysis considered the broader set of outcomes reported in the meta-analysis. The base-case and secondary analyses reported an additional 0.018 and 0.013 quality-adjusted life years (QALYs) and cost savings of $236 and $288, respectively with Co-Cr EES versus BMS. Results were robust to sensitivity analyses and were most sensitive to the price of clopidogrel. In the probabilistic sensitivity analysis, Co-Cr EES was associated with a greater than 99% chance of being cost saving or cost effective (at a cost per QALY threshold of $50,000) versus BMS. Using data from a recent patient level meta-analysis and contemporary cost data, this analysis found that PCI with Co-Cr EES is more effective and less costly than PCI with BMS. © 2016 The Authors. Catheterization and Cardiovascular Interventions Published by Wiley Periodicals, Inc. © 2016 The Authors. Catheterization and Cardiovascular Interventions Published by Wiley Periodicals, Inc.

  12. Comparison of neointimal hyperplasia with drug-eluting stents versus bare metal stents in patients undergoing intracoronary bone-marrow mononuclear cell transplantation following acute myocardial infarction.

    PubMed

    Villa, Adolfo; Arnold, Roman; Sánchez, Pedro L; Gimeno, Federico; Ramos, Benigno; Cantero, Teresa; Fernández, Maria Eugenia; Sanz, Ricardo; Gutiérrez, Oliver; Mota, Pedro; García-Frade, Javier; San Román, José Alberto; Fernández-Avilés, Francisco

    2009-06-15

    The aims of this study were to assess the safety of drug-eluting stent (DES) use and to compare the incidence of in-stent restenosis (ISR) and neointimal hyperplasia formation according to the type of stent implanted (DES vs bare-metal stents [BMS]) in patients who underwent intracoronary bone marrow mononuclear cell transplantation after acute ST elevation myocardial infarction. Fifty-nine patients with successfully revascularized ST elevation myocardial infarction (37 using BMS and 22 using DES) underwent paired angiographic examinations at baseline and 6 to 9 months after the intracoronary injection of 91 million +/- 56 million autologous bone marrow mononuclear cells. A subgroup of 30 patients also underwent serial intravascular ultrasound examinations. Off-line angiographic assessment showed 4 cases of binary ISR, primarily in BMS (3 cases), and no major adverse cardiac events were associated with stent type (mean follow-up period 41 +/- 10 months). At follow-up, angiographic late luminal loss was significantly lower in patients with DES than in those patients with BMS (0.35 +/- 0.66 vs 0.71 +/- 0.38 mm, p = 0.011). Multivariate analysis identified the use of DES (beta = -0.32, 95% confidence interval [CI] -0.57 to -0.26, p = 0.03) and a smaller baseline reference vessel diameter (beta = 0.29, 95% CI 0.04 to 0.54, p = 0.02) as independent predictors of lower late loss. Moreover, intravascular ultrasound showed a significant reduction of in-stent neointimal hyperplasia formation related to DES use compared with BMS use (Delta neointimal hyperplasia volume 5.4 mm(3) [95% CI 2.7 to 28.1] vs 35.9 mm(3) [95% CI 22.0 to 43.6], p = 0.035). In conclusion, these findings suggest that the use of DES is safe and may prevent ISR and neointimal hyperplasia formation in patients who undergo intracoronary bone marrow mononuclear cell transplantation after a successfully revascularized ST elevation myocardial infarction.

  13. [The bioresorbable coronary stent: a revolution].

    PubMed

    Koegler, Flora; De Benedetti, Edoardo

    2013-04-10

    Coronary angioplasty has undergone several technological revolutions: starting with balloon angioplasty, then with bare metal stent and finally with drug eluting stent (DES), this technique is now mature. However, once we thought the problem of instent restenosis solved with DES, new concerns arise with late and very late stent thrombosis. Should we therefore proscribe DES? How long should be the duration of dual antiplatelet therapy? And how should we manage the patients who need a surgery and are at high risk of bleeding? Are bioresorbable stents the final solution with their initial mechanical properties, then with their drug eluting effect against intra-stent restenosis, and finally with their complete resorption which leaves the artery free of any foreign material?

  14. Type D personality predicts death or myocardial infarction after bare metal stent or sirolimus-eluting stent implantation: a Rapamycin-Eluting Stent Evaluated at Rotterdam Cardiology Hospital (RESEARCH) registry substudy.

    PubMed

    Pedersen, Susanne S; Lemos, Pedro A; van Vooren, Priya R; Liu, Tommy K K; Daemen, Joost; Erdman, Ruud A M; Smits, Pieter C; Serruys, Patrick W J C; van Domburg, Ron T

    2004-09-01

    We investigated the effect of Type D personality on the occurrence of adverse events at nine months in patients with ischemic heart disease (IHD) after percutaneous coronary intervention (PCI) with sirolimus-eluting stents (SESs) or bare stents. Type D patients experience increased negative emotions and tend not to express these emotions in social interactions. The SES is a new advent in interventional cardiology that reduces the restenosis rate and the risk of a major adverse cardiac event, but the SES has not been shown to confer any benefits on death or myocardial infarction (MI). Consecutive patients with IHD (n = 875) enrolled in the Rapamycin-Eluting Stent Evaluated At Rotterdam Cardiology Hospital (RESEARCH) registry completed the Type D Personality Scale (DS14) six months after PCI. The end point was a composite of death and MI. Events occurring before administration of the DS14 were excluded from analyses. At nine months' follow-up, there were 20 events. Type D patients were at a cumulative increased risk of adverse outcome compared with non-Type D patients: 5.6% versus 1.3% (p < 0.002). Type D personality (odds ratio [OR] 5.31; 95% confidence interval [CI] 2.06 to 13.66) remained an independent predictor of adverse outcome adjusting for all other variables, including SES versus bare-stent implantation. Type D personality was an independent predictor of adverse events in patients optimally treated with the latest advent in interventional cardiology. The DS14 could be used as a screening instrument in routine clinical practice to optimize risk stratification in IHD patients.

  15. Safety and efficacy of low-dose paclitaxel utilizing the cobra-P drug-eluting stent system with a novel biodegradable coating in de novo coronary lesions: the PLUS-ONE first-in-man study.

    PubMed

    Calderas, Carlos; Condado, Jose Francisco; Condado, Jose Antonio; Flores, Alejandra; Mueller, Amy; Thomas, Jack; Nakatani, Daisaku; Honda, Yasuhiro; Waseda, Katsuhisa; Fitzgerald, Peter

    2014-01-01

    The Cobra-P drug-eluting stent (DES) system consists of cobalt chromium alloy with bio-absorbable siloxane sol-gel matrix coating that elutes low dose paclitaxel within 6 months. The aim of this first-in-man trial was to evaluate the safety and performance of 2 doses of the Cobra-P DES. A total of 60 lesions (54 patients) were sequentially assigned to 2 different paclitaxel doses: group A (3.7 μg/18mm, n=30) or group B (8 μg/18mm, n=30). The primary endpoint was MACE at 4 months defined as cardiac death, myocardial infarction, and target lesion revascularization. Patient and lesion characteristics were matched between the 2 groups except for male sex. MACE at 4 months was 3.3% and 0% respectively (P=1.000) and at 1-year follow-up remained unchanged. In-stent late loss at 4 months was similar in both groups (0.36 ± 0.30mm and 0.34 ± 0.20mm P=.773). In this FIM study, implantation of the Cobra-P low dose paclitaxel-eluting stent with a bioabsorbable sol-gel coating was proven to be feasible and safe. Moderate neointimal proliferation was observed as well as an acceptable MACE rate up to 1 year. © 2014.

  16. Three-month evaluation of strut healing using a novel optical coherence tomography analytical method following bioresorbable polymer everolimus-eluting stent implantation in humans: the TIMELESS study.

    PubMed

    Vesga, Boris; Hernandez, Hector; Moncada, Miguel; Gasior, Pawel; Higuera, Sergio; Dager, Antonio; Arana, Camilo; Delgado, Juan A; Généreux, Philippe; Maehara, Akiko; Granada, Juan F

    2017-03-01

    Bioresorbable polymer drug-eluting stent technologies have been considered to have the potential to enhance vascular healing by reducing polymer exposure to the vessel wall, potentially allowing the earlier discontinuation of dual antiplatelet therapy. At present, the early vascular healing response to this type of technologies is still unclear. The TIMELESS study is a multicenter, prospective, single-arm study that enrolled real-world patients undergoing percutaneous coronary intervention. All patients underwent Synergy stent implantation, which consists of a platinum-chromium platform coated with an ultra-thin abluminal bioabsorbable poly-D,L-lactide-co-glycolide polymer-eluting everolimus. A total of 37 patients were included in the study. The majority of the patients underwent percutaneous coronary intervention because of acute coronary syndromes. At 3 months, angiographic follow-up showed a percentage diameter of stenosis of 8.1±7.5% and an angiographic late loss of 0.03±0.24 mm. In all analyzed struts, less than 1% of struts were definitely uncovered or covered with fibrin, 12.5% (5.0-18.5%) showed evidence of partial coverage, and the remaining (∼85%) were fully covered. No stent thrombosis was observed up to 12 months of clinical follow-up. In a real-world population, the implantation of a bioresorbable polymer drug-eluting stent resulted in almost complete strut coverage throughout the entire stent length at 3 months. The clinical implications for antiplatelet therapy and outcomes should be investigated further.

  17. One-year clinical outcomes of BioMatrix™-Biolimus A9™ eluting stent: the e-BioMatrix multicenter post marketing surveillance registry in India.

    PubMed

    Mehta, Ashwin B; Chandra, Praveen; Dalal, Jamshed; Shetty, Prabhakar; Desai, Devang; Chocklingam, K; Prajapati, Jayesh; Kumar, Pramod; Magarkar, Vilas; Vasawada, Apurva; Goyal, B K; Kumar, Viveka; Rao, V Suryaprakash; Babu, Ramesh; Parikh, Pritesh; Kaul, Upendra; Patil, Aruna; Mhetre, Tushar; Rangnekar, Hrishikesh

    2013-01-01

    The e-BioMatrix is a post marketing multicenter registry with an objective to evaluate the 2 year clinical safety and efficacy outcomes in patients treated with BioMatrix™ - Biolimus A9™ (BA9™) drug eluting stents (DES). Drug-eluting stents still have late-stage disadvantages that might be attributable to the permanent polymer. BioMatrix a new generation DES containing anti-proliferative drug Biolimus A9™ incorporating a biodegradable abluminal coating that leaves a polymer-free stent after drug release enhancing strut coverage while preventing neointimal hyperplasia. This interim analysis consists of a total of 1189 patients with 1418 lesions treated with BioMatrix stent who entered this multicenter registry in India. We analyzed the incidence of major adverse cardiac events (MACE) and stent thrombosis (ST) at 1, 6, and 12 months with an extended follow-up of 2 years. Recommended antiplatelet regimen included clopidogrel and aspirin for 12 months. The mean age was 57.6 ± 10.9 years, 81.8% were males, comorbidity index was 1.20 ± 1.33, 68% presented with acute coronary syndrome, 49% had hypertension and 40.8% had diabetes mellitus. One-year clinical follow-up was completed in 987 patients at the time of interim analysis. The incidence of MACE is 0.45 for 1544 person-year follow-up. There were only 03 cases of ST (01 late ST) reported during this time. This registry demonstrates excellent one-year clinical safety and efficacy of BioMatrix stents. The 1-year result shows that BioMatrix stent may be a suitable alternative as compared to contemporary DESs which are currently available in the market for simple as well complex disease. Copyright © 2013 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  18. Sustained risk of stent thrombosis and restenosis in first generation drug-eluting Stents after One Decade of Follow-up: A Report from the Swedish Coronary Angiography and Angioplasty Registry (SCAAR).

    PubMed

    Völz, Sebastian; Angerås, Oskar; Odenstedt, Jacob; Ioanes, Dan; Haraldsson, Inger; Dworeck, Christian; Redfors, Björn; Råmunddal, Truls; Albertsson, Per; Petursson, Petur; Omerovic, Elmir

    2018-05-10

    Long-term comparisons between Drug-eluting stent and bare metal stent are not well-studied. The aim of this study was to compare two stents that were previously frequently used in regard to long-term risk of restenosis and stent thrombosis (ST). We used data from the SCAAR registry. Consecutive procedures performed between 2004 and 2014 for stable angina, UA/NSTEMI and STEMI were included. We compared two different stents: Cordis Cypher Select (C-CS), and Boston Scientific Liberte (BS-L), modeling data with multilevel Cox proportional-hazards regression. The primary endpoint was time to first occurrence of either ST or restenosis. During the study period 2210 C-CS and 6941 B-SL were implanted in 5,314 patients. Mean follow-up time was 2,288 days for C-CS and 2,297 days for BS-L. Treatment with C-CS was associated with lower risk for restenosis or ST up to one year from index procedure (HR 0.41; 95% CI 0.32-0.52; P < .001). However, after one year of follow-up, risk was substantially higher in C-CS (HR 2.81; 95% CI 2.25-3.50; P < .001). Treatment with C-CS was not associated with better outcome than BS-L. Continuation of restenosis and ST long after the index procedure with C-CS present a major concern for patient safety. © 2018 Wiley Periodicals, Inc.

  19. Drug-Eluting Versus Bare-Metal Stents During PCI in Patients With End-Stage Renal Disease on Dialysis

    PubMed Central

    Chang, Tara I.; Montez-Rath, Maria E.; Tsai, Thomas T.; Hlatky, Mark A.; Winkelmayer, Wolfgang C.

    2016-01-01

    BACKGROUND In patients undergoing percutaneous coronary intervention (PCI), drug-eluting stents (DES) reduce repeat revascularizations compared with bare metal stents (BMS), but their effects on death and myocardial infarction (MI) are mixed. Few studies have focused on patients with end-stage renal disease (ESRD). OBJECTIVES We compared mortality and cardiovascular morbidity during PCI with DES and with BMS in dialysis patients. METHODS We identified 36,117 dialysis patients from the U.S. Renal Data System who had coronary stenting in the U.S. between 4/23/03 and 12/31/10, and examined the association of DES versus BMS with 1-year outcomes: death; death or MI; and death, MI or repeat revascularization. We conducted a temporal analysis by dividing the study period into 3 DES eras: Transitional (4/23/03 – 6/30/04); Liberal (7/1/04 – 12/31/06); and Selective (1/1/07 – 12/31/10). RESULTS One-year event rates were high, with 38 deaths, 55 death or MI events and 71 death, MI or repeat revascularization events per 100 person-years. DES was associated with a significant 18% lower risk of death, 16% lower risk of death or MI, and 13% lower risk of death, MI or repeat revascularization, compared with BMS. DES use varied, from 56% in the Transitional era to 85% in the Liberal era and 62% in the Selective era. DES outcomes in the Liberal era were significantly better than in the Transitional Era, but not significantly better than in the Selective Era. CONCLUSIONS DES for PCI appears safe in U.S. dialysis patients, and is associated with lower rates of death, MI and repeat revascularization. PMID:27012407

  20. Technological Advances in Stent Therapies: a Year in Review.

    PubMed

    Raffoul, Jad; Nasir, Ammar; Klein, Andrew J P

    2018-04-07

    Stent technology has rapidly evolved since the first stainless steel bare metal stents with substantial developments in scaffolding, polymer, drug choice, drug delivery, and elution mechanisms. Most recently, there has been the evolution of bioabsorbable vascular scaffolds, potentially eliminating the need for long-term foreign object retention. These rapid developments have led to an ever-expanding selection of new stents, making the choice of which to use in which patient challenging. Operators must balance potential short- and long-term clinical ramifications, namely stent thrombosis, in-stent restenosis, target lesion revascularization, and target lesion failure. In this review, we hope to provide insight for interventional cardiologists on the details of stent technology and how this impacts outcomes, stent selection, and duration of dual-antiplatelet therapy duration post drug-eluting stent implantation.

  1. Vorinostat-eluting poly(DL-lactide-co-glycolide) nanofiber-coated stent for inhibition of cholangiocarcinoma cells

    PubMed Central

    Song, Yeon Hui; Kim, Chan; Kim, Jungsoo; Seo, Sol-Ji; Jeong, Young-Il; Kang, Dae Hwan

    2017-01-01

    Purpose The aim of this study was to fabricate a vorinostat (Zolinza™)-eluting nanofiber membrane-coated gastrointestinal (GI) stent and to study its antitumor activity against cholangiocarcinoma (CCA) cells in vitro and in vivo. Methods Vorinostat and poly(DL-lactide-co-glycolide) dissolved in an organic solvent was sprayed onto a GI stent to make a nanofiber-coated stent using an electro-spinning machine. Intact vorinostat and vorinostat released from nanofibers was used to assess anticancer activity in vitro against various CCA cells. The antitumor activity of the vorinostat-eluting nanofiber membrane-coated stent was evaluated using HuCC-T1 bearing mice. Results A vorinostat-incorporated polymer nanofiber membrane was formed on the surface of the GI stent. Vorinostat was continuously released from the nanofiber membrane over 10 days, and its release rate was higher in cell culture media than in phosphate-buffered saline. Released vorinostat showed similar anticancer activity against various CCA cells in vitro compared to that of vorinostat. Like vorinostat, vorinostat released from nanofibers induced acetylation of histone H4 and inhibited histone deacetylases 1⋅3⋅4/5/7 expression in vitro and in vivo. Furthermore, vorinostat nanofibers showed a higher tumor growth inhibition rate in HuCC-T1 bearing mice than vorinostat injections. Conclusion Vorinostat-eluting nanofiber membranes showed significant antitumor activity against CCA cells in vitro and in vivo. We suggest the vorinostat nanofiber-coated stent may be a promising candidate for CCA treatment. PMID:29089762

  2. Expert consensus (SBC/SBHCI) on the use of drug-eluting stents: recommendations of the Brazilian society of interventional cardiology/ Brazilian society of cardiology for the Brazilian public single healthcare system.

    PubMed

    Lima, Valter C; Mattos, Luiz Alberto P; Caramori, Paulo R A; Perin, Marco A; Mangione, José A; Machado, Bruno M; Coelho, Wilson M C; Bueno, Ronaldo R L

    2006-10-01

    The authors review percutaneous coronary intervention (PCI) evolution and its growing application in myocardial revascularization for patients with coronary heart disease in Brazil and worldwide. PCI was introduced in 1977 using only the catheter balloon. Limitations of this method (acute occlusion and coronary restenosis) led to the adoption of coronary stents and more recently the advent of drug-eluting stents2, which were developed to drastically reduce restenosis rates. These developments allowed the exponential growth of percutaneous coronary intervention (PCI) procedures in Brazil which have replaced many bypass surgery procedures and have become the gold standard for the majority of symptomatic patients suffering from coronary artery disease. The preference for this procedure gained new dimensions in 2000 when the Brazilian Public Healthcare System (SUS) began reimbursing for stent procedures. This measure exemplified the importance of the Public Healthcare System's participation in incorporating medical advances and offering a high standard of cardiovascular treatment to a large portion of the Brazilian population. It is emphasized that prevention of in-stent restenosis is complex due to its unpredictable and ubiquitous occurrence. Control of this condition improves quality of life and reduces the recurrence of angina pectoris, the need to perform new revascularization procedures and hospital readmissions. The overall success of the drug-eluting stents has proven to be reliable and consistent in overcoming restenosis and has some beneficial impact for all clinical and angiographic conditions. This paper discusses the adoption and criteria for the use of drug-eluting stents in other countries as well as the recommendations established by the Brazilian Society of Interventional Cardiology for their reimbursement by SUS. The incorporation of new healthcare technology involves two distinct stages. During the first stage, the product is registered with the

  3. Comparison of the long-term safety and efficacy of drug-eluting and bare-metal stent implantation in saphenous vein grafts.

    PubMed

    Latib, Azeem; Ferri, Luca; Ielasi, Alfonso; Cosgrave, John; Godino, Cosmo; Bonizzoni, Erminio; Romagnoli, Enrico; Chieffo, Alaide; Valgimigli, Marco; Penzo, Carlo; Carlino, Mauro; Michev, Iassen; Sangiorgi, Giuseppe M; Montorfano, Matteo; Airoldi, Flavio; Colombo, Antonio

    2010-06-01

    Concerns about the long-term safety of drug-eluting stents (DES) in saphenous vein grafts has become an area of controversy and uncertainty. In this retrospective registry, we compared the outcomes in 127 patients (143 lesions) treated with DES from April 2002 to June 2006 (DES group) with 131 patients (160 lesions) treated with bare-metal stents in the preceding 36 months (bare-metal stent group). End points analyzed were cumulative death, myocardial infarction, and target vessel revascularization at 2 years after stent implantation. The DES group was significantly (P<0.05) more complex with a greater frequency of diabetes (33.1%versus 15.3%), older grafts (11.6+/-5.3 years versus 9.6+/-5.2 years), restenotic lesions (23.8% versus 4.4%), total occlusions (7.7% versus 1.2%), and smaller grafts (3.16+/-0.66 mm versus 3.44+/-0.76 mm) treated with longer stents (34.1+/-25.1 mm versus 22.7+/-11.6 mm). At 2 years, there was no statistical difference in death (8.7% versus 7.8%), myocardial infarction (6.3% versus 9.4%), or target vessel revascularization (19.7% versus 24.2%) between DES and bare-metal stents, respectively. A propensity analysis to adjust for baseline differences suggested that there was no observed association between DES and increased mortality (hazard ratio, 0.72; 95% CI, 0.21 to 2.44; P=0.60) but possibly an association with a reduction in target vessel revascularization (hazard ratio, 0.31; 95% CI, 0.14 to 0.66; P=0.002). Despite being implanted in patients and lesions more complex than the bare-metal stent group, there was no observed association between DES implantation in saphenous vein grafts and an increase in late mortality. DES may maintain their efficacy in reducing revascularization rates in diseased saphenous vein grafts over a 2-year follow-up period.

  4. [Assessment of the course of ischemic heart disease after placement of stents with drug covering and uncovered metal stents: data of 3 years follow-up].

    PubMed

    Buza, V V; Karpov, Iu A; Samko, A N; Deev, A D; Lopukhova, V V; Levitskiĭ, I V; Sozykin, A V

    2009-01-01

    The placement of sirolimus-eluting stents decreases the frequency of repeat revascularization procedures in patients undergoing percutaneous coronary intervention (PCI) in randomized clinical trials. However, there is uncertainty about the effectiveness of sirolimus-eluting stents, and increasing concern about their safety in routine clinical practice. From the prof. Samko PCI laboratory in Moscow, Russia, we identified 426 patients, who received either bare-metal stents alone or sirolimus-eluting stents alone during an index PCI procedure between March 1, 2002, and September 31, 2004.The primary outcomes of the study were the rates of target-lesion revascularization, myocardial infarction, death, late stent thrombosis. The 3-year rate of target-lesion revascularization was significantly lower among patients who received sirolimus-eluting stents than among those who received bare-metal stents (3.1% vs. 19 %, p=0.001). The 3-year mortality rate was not different between the bare-metal stent group and the sirolimus eluting stent group (5.9% vs. 7.2%, p=0.68), the 3-year rate of all ARC late stent thrombosis was similar in the two groups (5.9% and 7.2%, respectively; p=0.95). Sirolimus-eluting stents are effective in reducing the need for target-vessel revascularization without significantly increased rates of death, late stent thrombosis, myocardial infarction.

  5. Percutaneous coronary intervention with second-generation drug-eluting stent versus bare-metal stent: Systematic review and cost-benefit analysis.

    PubMed

    Poder, Thomas G; Erraji, Jihane; Coulibaly, Lucien P; Koffi, Kouamé

    2017-01-01

    Drug-eluting stents (DESs) were considered as ground-breaking technology promising to eradicate restenosis and the necessity to perform multiple revascularization procedures subsequent to percutaneous coronary intervention. Soon after DESs were released on the market, however, there were reports of a potential increase in mortality and of early or late thrombosis. In addition, DESs are far more expensive than bare-metal stents (BMSs), which has led to their limited use in many countries. The technology has improved over the last few years with the second generation of DESs (DES-2). Moreover, costs have come down and an improved safety profile with decreased thrombosis has been reported. Perform a cost-benefit analysis of DES-2s versus BMSs in the context of a publicly funded university hospital in Quebec, Canada. A systematic review of meta-analyses was conducted between 2012 and 2016 to extract data on clinical effectiveness. The clinical outcome of interest for the cost-benefit analysis was target-vessel revascularization (TVR). Cost units are those used in the Quebec health-care system. The cost-benefit analysis was based on a 2-year perspective. Deterministic and stochastic models (discrete-event simulation) were used, and various risk factors of reintervention were considered. DES-2s are much more effective than BMSs with respect to TVR rate ratio (i.e., 0.29 to 0.62 in more recent meta-analyses). DES-2s seem to cause fewer deaths and in-stent thrombosis than BMSs, but results are rarely significant, with the exception of the cobalt-chromium everolimus DES. The rate ratio of myocardial infraction is systematically in favor of DES-2s and very often significant. Despite the higher cost of DES-2s, fewer reinterventions can lead to huge savings (i.e., -$479 to -$769 per patient). Moreover, the higher a patient's risk of reintervention, the higher the savings associated with the use of DES-2s. Despite the higher purchase cost of DES-2s compared to BMSs

  6. Percutaneous coronary intervention with second-generation drug-eluting stent versus bare-metal stent: Systematic review and cost–benefit analysis

    PubMed Central

    Erraji, Jihane; Coulibaly, Lucien P.; Koffi, Kouamé

    2017-01-01

    Background Drug-eluting stents (DESs) were considered as ground-breaking technology promising to eradicate restenosis and the necessity to perform multiple revascularization procedures subsequent to percutaneous coronary intervention. Soon after DESs were released on the market, however, there were reports of a potential increase in mortality and of early or late thrombosis. In addition, DESs are far more expensive than bare-metal stents (BMSs), which has led to their limited use in many countries. The technology has improved over the last few years with the second generation of DESs (DES-2). Moreover, costs have come down and an improved safety profile with decreased thrombosis has been reported. Objective Perform a cost–benefit analysis of DES-2s versus BMSs in the context of a publicly funded university hospital in Quebec, Canada. Methods A systematic review of meta-analyses was conducted between 2012 and 2016 to extract data on clinical effectiveness. The clinical outcome of interest for the cost–benefit analysis was target-vessel revascularization (TVR). Cost units are those used in the Quebec health-care system. The cost–benefit analysis was based on a 2-year perspective. Deterministic and stochastic models (discrete-event simulation) were used, and various risk factors of reintervention were considered. Results DES-2s are much more effective than BMSs with respect to TVR rate ratio (i.e., 0.29 to 0.62 in more recent meta-analyses). DES-2s seem to cause fewer deaths and in-stent thrombosis than BMSs, but results are rarely significant, with the exception of the cobalt–chromium everolimus DES. The rate ratio of myocardial infraction is systematically in favor of DES-2s and very often significant. Despite the higher cost of DES-2s, fewer reinterventions can lead to huge savings (i.e., -$479 to -$769 per patient). Moreover, the higher a patient’s risk of reintervention, the higher the savings associated with the use of DES-2s. Conclusion Despite the

  7. Previous coronary stent implantation and cardiac events in patients undergoing noncardiac surgery.

    PubMed

    Cruden, Nicholas L M; Harding, Scott A; Flapan, Andrew D; Graham, Cat; Wild, Sarah H; Slack, Rachel; Pell, Jill P; Newby, David E

    2010-06-01

    Noncardiac surgery performed after coronary stent implantation is associated with an increased risk of stent thrombosis, myocardial infarction, and death. The influence of stent type and period of risk still have to be defined. We linked the Scottish Coronary Revascularisation Register with hospital admission data to undertake a Scotland-wide retrospective cohort study examining cardiac outcomes in all patients who received drug-eluting or bare-metal stents between April 2003 and March 2007 and subsequently underwent noncardiac surgery. Of 1953 patients, 570 (29%) were treated with at least 1 drug-eluting stent and 1383 (71%) with bare-metal stents only. There were no differences between drug-eluting and bare-metal stents in the primary end point of in-hospital mortality or ischemic cardiac events (14.6% versus 13.3%; P=0.3) or the secondary end points of in-hospital mortality (0.7% versus 0.6%; P=0.8) and acute myocardial infarction (1.2% versus 0.7%; P=0.3). Perioperative death and ischemic cardiac events occurred more frequently when surgery was performed within 42 days of stent implantation (42.4% versus 12.8% beyond 42 days; P<0.001), especially in patients revascularized after an acute coronary syndrome (65% versus 32%; P=0.037). There were no temporal differences in outcomes between the drug-eluting and bare-metal stent groups. Patients undergoing noncardiac surgery after recent coronary stent implantation are at increased risk of perioperative myocardial ischemia, myocardial infarction, and death, particularly after an acute coronary syndrome. For at least 2 years after percutaneous coronary intervention, cardiac outcomes after noncardiac surgery are similar for both drug-eluting and bare-metal stents.

  8. A Budget Impact Model for Paclitaxel-eluting Stent in Femoropopliteal Disease in France

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    De Cock, Erwin, E-mail: erwin.decock@unitedbiosource.com; Sapoval, Marc, E-mail: Marc.sapoval2@egp.aphp.fr; Julia, Pierre, E-mail: pierre.julia@egp.aphp.fr

    2013-04-15

    The Zilver PTX drug-eluting stent (Cook Ireland Ltd., Limerick, Ireland) represents an advance in endovascular treatments for atherosclerotic superficial femoral artery (SFA) disease. Clinical data demonstrate improved clinical outcomes compared to bare-metal stents (BMS). This analysis assessed the likely impact on the French public health care budget of introducing reimbursement for the Zilver PTX stent. A model was developed in Microsoft Excel to estimate the impact of a progressive transition from BMS to Zilver PTX over a 5-year horizon. The number of patients undergoing SFA stenting was estimated on the basis of hospital episode data. The analysis from the payermore » perspective used French reimbursement tariffs. Target lesion revascularization (TLR) after primary stent placement was the primary outcome. TLR rates were based on 2-year data from the Zilver PTX single-arm study (6 and 9 %) and BMS rates reported in the literature (average 16 and 22 %) and extrapolated to 5 years. Net budget impact was expressed as the difference in total costs (primary stenting and reinterventions) for a scenario where BMS is progressively replaced by Zilver PTX compared to a scenario of BMS only. The model estimated a net cumulative 5-year budget reduction of Euro-Sign 6,807,202 for a projected population of 82,316 patients (21,361 receiving Zilver PTX). Base case results were confirmed in sensitivity analyses. Adoption of Zilver PTX could lead to important savings for the French public health care payer. Despite higher initial reimbursement for the Zilver PTX stent, fewer expected SFA reinterventions after the primary stenting procedure result in net savings.« less

  9. Rapid Globalization of Medical Device Clinical Development Programs in Japan - The Case of Drug-Eluting Stents.

    PubMed

    Murakami, Madoka; Suzuki, Yuka; Tominaga, Toshiyoshi

    2018-02-23

    Delays in the introduction to the Japanese market of drug-eluting stents (DES) developed overseas (i.e., "device lag") decreased sharply between 2004 and 2012. The reduction accompanied a shift in clinical development from a succession pattern (initial product development and approval overseas followed by eventual entrance into the Japanese market) to parallel development (employing multiregional clinical trials (MRCTs)). Although resource-intensive in the short-term, MRCTs are proving to be an effective tool in simultaneous global product development. Creative study designs and the absence of significant ethnic differences in Japanese subjects regarding DES safety and efficacy and the pharmacokinetic behavior of their coating drugs propel this process. More general factors such as medical need and industry incentivization also encourage this shift. Physicians' preference for DES over other percutaneous coronary interventions, the expanding global DES market, and streamlined development and approval prospects each motivate industry to continue investing in DES product development. The efforts of various stakeholders were also integral to overcoming practical obstacles, and contributions by 'Harmonization by Doing' and a premarket collaboration initiative between the USA and Japan were particularly effective. Today, USA/Japan regulatory cooperation is routine, and Japan is now integrated into global medical device development. MRCTs including Japanese subjects, sites, and investigators are now commonplace.

  10. Comparison of the 9-month intra-stent conditions and 2-year clinical outcomes after Resolute zotarolimus-eluting stent implantation between 3-month and standard dual antiplatelet therapy.

    PubMed

    Fujimoto, Wataru; Sawada, Takahiro; Toba, Takayoshi; Takahashi, Yu; Miyata, Taishi; Oishi, Shogo; Osue, Tsuyoshi; Onishi, Tetsuari; Takaya, Tomofumi; Shimane, Akira; Taniguchi, Yasuyo; Kawai, Hiroya; Yasaka, Yoshinori

    2018-07-01

    The use of short-duration dual antiplatelet therapy (DAPT) remains controversial. To investigate efficacy and safety of short-duration DAPT, we performed a detailed comparison of intra-stent conditions by optical coherence tomography (OCT) after second-generation drug-eluting stent implantation with short-term and standard DAPT. Eighty-two consecutive patients with stable angina pectoris who received Resolute zotarolimus-eluting stents (R-ZESs; Medtronic Cardiovascular, Santa Rosa, CA, USA) were enrolled. Patients were assigned to 3-month (3M group: 41 patients) and standard (standard group: 41 patients) DAPT. In the 3M group, clopidogrel was discontinued 3 months after stent implantation. In the standard group, DAPT was maintained until follow-up OCT. At 9 months, neointimal proliferation was significantly larger in the 3M group, but there were no significant between-group differences in the proportion of uncovered and malapposed strut. The prevalence of abnormal intra-stent tissue (AIT) at 9 months was equivalent between groups. A multiple regression analysis revealed malapposition at 9 months as the strongest independent predictor of AIT at 9 months, and the prevalence of AIT was not associated with DAPT duration. Over 2 years, cardiac events were equal between groups; however, major bleeding was higher tendency in the standard group than in the 3M group. This OCT study indicated that reducing DAPT's duration may provide acceptable arterial healing in patients with implanted R-ZESs. Copyright © 2018 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  11. A stent for co-delivering paclitaxel and nitric oxide from abluminal and luminal surfaces: Preparation, surface characterization, and in vitro drug release studies

    NASA Astrophysics Data System (ADS)

    Gallo, Annemarie; Mani, Gopinath

    2013-08-01

    Most drug-eluting stents currently available are coated with anti-proliferative drugs on both abluminal (toward blood vessel wall) and luminal (toward lumen) surfaces to prevent neointimal hyperplasia. While the abluminal delivery of anti-proliferative drugs is useful for controlling neointimal hyperplasia, the luminal delivery of such drugs impairs or prevents endothelialization which causes late stent thrombosis. This research is focused on developing a bidirectional dual drug-eluting stent to co-deliver an anti-proliferative agent (paclitaxel - PAT) and an endothelial cell promoting agent (nitric oxide - NO) from abluminal and luminal surfaces of the stent, respectively. Phosphonoacetic acid, a polymer-free drug delivery platform, was initially coated on the stents. Then, the PAT and NO donor drugs were co-coated on the abluminal and luminal stent surfaces, respectively. The co-coating of drugs was collectively confirmed by the surface characterization techniques such as Fourier transform infrared spectroscopy, scanning electron microscopy (SEM), 3D optical surface profilometry, and contact angle goniometry. SEM showed that the integrity of the co-coating of drugs was maintained without delamination or cracks formation occurring during the stent expansion experiments. In vitro drug release studies showed that the PAT was released from the abluminal stent surfaces in a biphasic manner, which is an initial burst followed by a slow and sustained release. The NO was burst released from the luminal stent surfaces. Thus, this study demonstrated the co-delivery of PAT and NO from abluminal and luminal stent surfaces, respectively. The stent developed in this study has potential applications in inhibiting neointimal hyperplasia as well as encouraging luminal endothelialization to prevent late stent thrombosis.

  12. Incidence and Clinical Outcomes of Stent Fractures on the Basis of 6,555 Patients and 16,482 Drug-Eluting Stents From 4 Centers.

    PubMed

    Kan, Jing; Ge, Zhen; Zhang, Jun-Jie; Liu, Zhi-Zhong; Tian, Nai-Liang; Ye, Fei; Li, Sui-Ji; Qian, Xue-Song; Yang, Song; Chen, Meng-Xuan; Rab, Tanveer; Chen, Shao-Liang

    2016-06-13

    The present study aimed to analyze the incidence of SF and its correlation with clinical events after DES implantation and the outcome of re-intervention for symptomatic in-stent restenosis (ISR) induced by stent fracture (SF). SF is associated with a high rate of clinical events after the implantation of drug-eluting stents (DES). However, the chronological rate of SF and the effect of SF on clinical outcomes from a large patient population remain underreported. A total of 6,555 patients with 16482 DES in 10751 diseased vessels and surveillance angiography between November 2003 and January 2014 were prospectively studied. The primary endpoints included the incidence of SF, in-stent restenosis (ISR), target lesion revascularization (TLR), and definite stent thrombosis (ST) at the end of follow-up before and after propensity score matching. Clinical outcomes after TLR were also followed up. The SF rate was detected in 803 (12.3%) patients, 3,630 (22.0%) stents, and 1,852 (17.2%) diseased vessels. SF increased over time. SF was associated with higher unadjusted rates of ISR (42.1%), TLR (24.8%, n = 379), and definite ST (4.6%) compared with stents without fracture (10.7%, 6.6%, and 1.03%, all p < 0.001), and the differences remained significant after propensity score matching (all p < 0.05). There was no significant difference in any-cause or cardiac mortality between patients with and without SF. After 1,523 days of follow-up since the first surveillance angiography, repeat ISR was detected in 90 of 379 (23.8%) stents after reintervention, and 6 (7.5%) stents required repeat TLR. SF is more frequently observed after DES implantation. TLR was required in almost one-fourth of fractured stents. Increased events in the SF group did not translate into a difference in mortality compared with the non-SF group. Reintervention was associated with acceptable clinical results. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All

  13. Biodegradable polymer sirolimus-eluting stents versus durable polymer everolimus-eluting stents for primary percutaneous coronary revascularisation of acute myocardial infarction.

    PubMed

    Pilgrim, Thomas; Piccolo, Raffaele; Heg, Dik; Roffi, Marco; Tüller, David; Vuilliomenet, André; Muller, Olivier; Cook, Stéphane; Weilenmann, Daniel; Kaiser, Christoph; Jamshidi, Peiman; Khattab, Ahmed A; Taniwaki, Masanori; Rigamonti, Fabio; Nietlispach, Fabian; Blöchlinger, Stefan; Wenaweser, Peter; Jüni, Peter; Windecker, Stephan

    2016-12-10

    Our aim was to compare the safety and efficacy of a novel, ultrathin strut, biodegradable polymer sirolimus-eluting stent (BP-SES) with a thin strut, durable polymer everolimus-eluting stent (DP-EES) in a pre-specified subgroup of patients with acute ST-segment elevation myocardial infarction (STEMI) enrolled in the BIOSCIENCE trial. The BIOSCIENCE trial is an investigator-initiated, single-blind, multicentre, randomised non-inferiority trial (NCT01443104). Randomisation was stratified according to the presence or absence of STEMI. The primary endpoint, target lesion failure (TLF), is a composite of cardiac death, target vessel myocardial infarction, and clinically indicated target lesion revascularisation within 12 months. Between February 2012 and May 2013, 407 STEMI patients were randomly assigned to treatment with BP-SES or DP-EES. At one year, TLF occurred in seven (3.4%) patients treated with BP-SES and 17 (8.8%) patients treated with DP-EES (RR 0.38, 95% CI: 0.16-0.91, p=0.024). Rates of cardiac death were 1.5% in the BP-SES group and 4.7% in the DP-EES group (RR 0.31, 95% CI: 0.08-1.14, p=0.062); rates of target vessel myocardial infarction were 0.5% and 2.6% (RR 0.18, 95% CI: 0.02-1.57, p=0.082), respectively, and rates of clinically indicated target lesion revascularisation were 1.5% in the BP-SES group versus 2.1% in the DP-EES group (RR 0.69, 95% CI: 0.16-3.10, p=0.631). There was no difference in the risk of definite stent thrombosis. In this pre-specified subgroup analysis, BP-SES was associated with a lower rate of target lesion failure at one year compared to DP-EES in STEMI patients. These findings require confirmation in a dedicated STEMI trial.

  14. Acute ST-Elevation Myocardial Infarction after Coronary Stent Fracture.

    PubMed

    Rafighdust, Abbasali; Eshraghi, Ali

    2015-10-27

    The invention of the drug-eluting stent (DES) has brought about revolutionary changes in the field of interventional cardiology. In the DES era, in-stent restenosis has declined but new issues such as stent thrombosis have emerged. One of the emerging paradigms in the DES era is stent fracture. There are reports about stent fracture leading to in-stent restenosis or stent thrombosis. Most of these reports concern the Sirolimus-eluting stent. The present case is a representation of a Biolimus-eluting stent fracture. We introduce a 64-year-old male patient, for whom the BioMatrix stent was deployed in the right coronary artery. Five months after the implantation, he experienced acute myocardial infarction, with stent fracture leading to stent thrombosis being the causative mechanism. Another DES (Cypher) was used to manage this situation, and the final result was good.

  15. Influence of platform design of six different drug-eluting stents in provisional coronary bifurcation stenting by rePOT sequence: a comparative bench analysis.

    PubMed

    Derimay, François; Souteyrand, Geraud; Motreff, Pascal; Rioufol, Gilles; Finet, Gerard

    2017-10-13

    The rePOT (proximal optimisation technique) sequence proved significantly more effective than final kissing balloon (FKB) with two drug-eluting stents (DES) in a bench test. We sought to validate efficacy experimentally in a large range of latest-generation DES. On left main fractal coronary bifurcation bench models, five samples of each of the six main latest-generation DES (Coroflex ISAR, Orsiro, Promus PREMIER, Resolute Integrity, Ultimaster, XIENCE Xpedition) were implanted on rePOT (initial POT, side branch inflation, final POT). Proximal elliptical ratio, side branch obstruction (SBO), stent overstretch and strut malapposition were quantified on 2D and 3D OCT. Results were compared to FKB with Promus PREMIER. Whatever the design, rePOT maintained vessel circularity compared to FKB: elliptical ratio, 1.02±0.01 to 1.04±0.01 vs. 1.26±0.02 (p<0.05). Global strut malapposition was much lower: 2.6±1.4% to 0.1±0.2% vs. 40.4±8.4% for FKB (p<0.05). However, only Promus PREMIER and XIENCE Xpedition achieved significantly less SBO: respectively, 5.6±3.5% and 10.0±5.3% vs. 23.5±5.7% for FKB (p<0.05). Platform design differences had little influence on the excellent results of rePOT versus FKB. RePOT optimised strut apposition without proximal elliptical deformation in the six main latest-generation DES. Thickness and design characteristics seemed relevant for optimising SBO.

  16. Comparison of the endothelial coverage in everolimus and zotarolimus-eluting stents in normal, atherosclerotic, and bifurcation rabbit iliac arteries.

    PubMed

    Torii, Sho; Nakazawa, Gaku; Ijichi, Takeshi; Yoshikawa, Ayako; Ohno, Yohei; Ikari, Yuji

    2018-01-01

    The aim of this study is to evaluate differences in stent endothelial coverage among the second generation of drug-eluting stents. Incomplete stent coverage is one of the major causes of late stent thrombosis. Rabbits fed a normal diet received an everolimus (Xience Prime; EES) and a zotarolimus-eluting stent (Resolute Integrity; R-ZES) in each iliac artery, followed by sacrifice at 14 and 28 days after stent implantation. In addition, a group of atherosclerotic rabbits similarly received EES and R-ZES, and were sacrificed at 28 days. The extent of stent endothelial coverage was assessed by scanning electron microscopy. To evaluate endothelial coverage after bifurcation stenting, rabbits received EES and R-ZES placed with culotte stenting at the iliac bifurcation, followed by sacrifice at 14 and 28 days. In rabbits fed a normal diet, the percent uncovered strut area 14 days after stent implantation was significantly higher in R-ZES than in EES (10.1% (IQR 9.8-15.5) vs. 3.0% (IQR 1.5-9.7), p = 0.03), whereas it was not significantly different at 28-days (3.9% (IQR 0.8-10.3) vs. 1.0% (IQR 0.0-2.8), p = 0.2). In rabbits with induced atheroma, R-ZES also showed less endothelial coverage 28 days after stent implantation (5.3% (IQR 2.2-9.9) vs. 1.1% (IQR 0-6.2), p = 0.03). In the culotte stenting model, the percent uncovered strut area of the proximal overlapped segment was significantly higher in R-ZES at 14 days (15.8% (IQR 14.3-17.7) vs. 8.8% (IQR 8.3-9.8), p = 0.03) and 28 days (9.9% (IQR 4.1-13.9) vs. 2.5% (IQR 1.6-6.7), p = 0.04) after stent implantation. The carina area also showed a better coverage in EES compared with R-ZES. EES showed a better stent endothelial coverage compared with R-ZES after stent implantation in the early phase in normals, in arteries with lipid rich plaque, and in bifurcation stented sites.

  17. Drug-Eluting Stents versus Bare-Metal Stents in Taiwanese Patients with Acute Coronary Syndrome: An Outcome Report of a Multicenter Registry

    PubMed Central

    Lai, Chi-Cheng; Yip, Hon-Kan; Lin, Tsung-Hsien; Wu, Chiung-Jen; Lai, Wen-Ter; Liu, Chun-Peng; Chang, Shu-Chen; Mar, Guang-Yuan

    2014-01-01

    Background The study aims to compare cardiovascular outcomes of using bare-metal stents (BMS) and drug-eluting stents (DES) in patients with acute coronary syndrome (ACS) through analysis of the database from the Taiwan ACS registry. Large domestic studies comparing outcomes of interventional strategies using DES and BMS in a Taiwanese population with ACS are limited. Methods and Results Collected data regarding characteristics and cardiovascular outcomes from the registry database were compared between the BMS and DES groups. A Cox regression model was used in an unadjusted or adjusted manner for analysis. Baseline characteristics apparently varied between DES group (n = 650) and BMS group (n = 1672) such as ACS types, Killip’s classifications, or coronary blood flows. Compared with the BMS group, the DES group was associated with significantly lower cumulative incidence of all-cause mortality (3.4% vs. 5.8%, p = 0.008), target vessel revascularization (TVR) (5.2% vs. 7.4%, p = 0.035), or major adverse cardiac events (MACE) (10.2% vs. 15.6%, p < 0.001) at 1 year in a real-world setting. Cox regression analysis showed the BMS group referenced as the DES group had significantly higher risk-adjusted total mortality [hazard ratio (HR) = 1.85, p = 0.026], target vessel revascularization (TVR) (HR = 1.59, p = 0.035), and MACE (HR = 1.68, p = 0.001). Conclusions The data show use of DES over BMS provided advantages to patients with ACS in terms of lower 1-year mortality, TVR, and MACE. The study suggests implantation of DES compared with BMS in Taiwanese patients with ACS is safe and beneficial in the real-world setting. PMID:27122834

  18. Stent thrombosis and major clinical events at 3 years after zotarolimus-eluting or sirolimus-eluting coronary stent implantation: a randomised, multicentre, open-label, controlled trial.

    PubMed

    Camenzind, Edoardo; Wijns, William; Mauri, Laura; Kurowski, Volkhard; Parikh, Keyur; Gao, Runlin; Bode, Christoph; Greenwood, John P; Boersma, Eric; Vranckx, Pascal; McFadden, Eugene; Serruys, Patrick W; O'Neil, William W; Jorissen, Brenda; Van Leeuwen, Frank; Steg, Ph Gabriel

    2012-10-20

    We sought to compare the long-term safety of two devices with different antiproliferative properties: the Endeavor zotarolimus-eluting stent (E-ZES; Medtronic, Inc) and the Cypher sirolimus-eluting stent (C-SES; Cordis, Johnson & Johnson) in a broad group of patients and lesions. Between May 21, 2007 and Dec 22, 2008, we recruited 8791 patients from 36 recruiting countries to participate in this open-label, multicentre, randomised, superiority trial. Eligible patients were those aged 18 years or older undergoing elective, unplanned, or emergency procedures in native coronary arteries. Patients were randomly assigned to either receive E-ZES and C-SES (ratio 1:1). Randomisation was stratified per centre with varying block sizes of four, six, or eight patients, and concealed with a central telephone-based or web-based allocation service. The primary outcome was definite or probable stent thrombosis at 3 years and was analysed by intention to treat. Patients and investigators were aware of treatment assignment. This trial is registered with ClinicalTrials.gov, number NCT00476957. PROTECT randomised 8791 patients, of whom 8709 provided consent to participate and were eligible: 4357 were allocated to the E-ZES group and 4352 patients to the C-SES group. At 3 years, rates of definite or probable stent thrombosis did not differ between groups (1·4% for E-ZES [predicted: 1·5%] vs 1·8% [predicted: 2·5%] for C-SES; hazard ratio [HR] 0·81, 95% CI 0·58-1·14, p=0·22). Dual antiplatelet therapy was used in 8402 (96%) patients at discharge, 7456 (88%) at 1 year, 3041 (37%) at 2 years, and 2364 (30%) at 3 years. No evidence of superiority of E-ZES compared with C-SES in definite or probable stent thrombosis rates was noted at 3 years. Time analysis suggests a difference in definite or probable stent thrombosis between groups is emerging over time, and a longer follow-up is therefore needed given the clinical relevance of stent thrombosis. Medtronic, Inc. Copyright © 2012

  19. Dual Antiplatelet Therapy for 6 Versus 18 Months After Biodegradable Polymer Drug-Eluting Stent Implantation.

    PubMed

    Nakamura, Masato; Iijima, Raisuke; Ako, Junya; Shinke, Toshiro; Okada, Hisayuki; Ito, Yoshiaki; Ando, Kenji; Anzai, Hitoshi; Tanaka, Hiroyuki; Ueda, Yasunori; Takiuchi, Shin; Nishida, Yasunori; Ohira, Hiroshi; Kawaguchi, Katsuhiro; Kadotani, Makoto; Niinuma, Hiroyuki; Omiya, Kazuto; Morita, Takashi; Zen, Kan; Yasaka, Yoshinori; Inoue, Kenji; Ishiwata, Sugao; Ochiai, Masahiko; Hamasaki, Toshimitsu; Yokoi, Hiroyoshi

    2017-06-26

    The NIPPON (Nobori Dual Antiplatelet Therapy as Appropriate Duration) study was a multicenter randomized investigation of the noninferiority of short-term versus long-term dual antiplatelet therapy (DAPT) in patients with implantation of the Nobori drug-eluting stent (DES) (Terumo, Tokyo, Japan), which has a biodegradable abluminal coating. The optimum duration of DAPT for patients with a biodegradable polymer-coated DES is unclear. The subjects were 3,773 patients with stable or acute coronary syndromes undergoing Nobori stent implantation. They were randomized 1:1 to receive DAPT for 6 or 18 months. The primary endpoint was net adverse clinical and cerebrovascular events (NACCE) (all-cause mortality, myocardial infarction, stroke, and major bleeding) from 6 to 18 months after stenting. Intention-to-treat analysis was performed in 3,307 patients who were followed for at least 6 months. NACCE occurred in 34 patients (2.1%) receiving short-term DAPT and 24 patients (1.5%) receiving long-term DAPT (difference 0.6%, 95% confidence interval [CI]: 1.5 to 0.3). Because the lower limit of the 95% CI was inside the specified margin of -2%, noninferiority of short-term DAPT was confirmed. Mortality was 1.0% with short-term DAPT versus 0.4% with long-term DAPT, whereas myocardial infarction was 0.2% versus 0.1%, and major bleeding was 0.7% versus 0.7%, respectively. The estimated probability of NACCE was lower in the long-term DAPT group (hazard ratio: 1.44, 95% CI: 0.86 to 2.43). Six months of DAPT was not inferior to 18 months of DAPT following implantation of a DES with a biodegradable abluminal coating. However, this result needs to be interpreted with caution given the open-label design and wide noninferiority margin of the present study. (Nobori Dual Antiplatelet Therapy as Appropriate Duration [NIPPON]; NCT01514227). Copyright © 2017. Published by Elsevier Inc.

  20. Aspiration Thrombectomy and Drug-Eluting Stent Implantation Decrease the Occurrence of Angina Pectoris One Year After Acute Myocardial Infarction.

    PubMed

    Lee, Wei-Chieh; Fang, Chih-Yuan; Chen, Huang-Chung; Hsueh, Shu-Kai; Chen, Chien-Jen; Yang, Cheng-Hsu; Yip, Hon-Kan; Hang, Chi-Ling; Wu, Chiung-Jen; Fang, Hsiu-Yu

    2016-04-01

    Angina pectoris is a treatable symptom that is associated with mortality and decreased quality of life. Angina eradication is a primary care goal of care after an acute myocardial infarction (AMI). Our aim was to evaluate factors influencing angina pectoris 1 year after an AMI.From January 2005 to December 2013, 1547 patient received primary percutaneous intervention in our hospital for an acute ST-segment elevation myocardial infarction (MI). Of these patients, 1336 patients did not experience post-MI angina during a 1-year follow-up, and 211 patients did. Univariate and multivariate logistic regression analyses were performed to identify the factors influencing angina pectoris 1 year after an AMI. Propensity score matched analyses were performed for subgroups analyses.The average age of the patients was 61.08 ± 12.77 years, with a range of 25 to 97 years, and 82.9% of the patients were male. During 1-year follow-up, 13.6% of the patients experienced post-MI angina. There was a longer chest pain-to-reperfusion time in the post-MI angina group (P = 0.01), as well as a higher fasting sugar level, glycohemoglobin (HbA1C), serum creatinine, troponin-I and creatine kinase MB (CK-MB). The post-MI angina group also had a higher prevalence of multiple-vessel disease. Manual thrombectomy, and distal protective device and intracoronary glycoprotein IIb/IIIa inhibitor injection were used frequently in the no post-MI angina group. Antiplatelet agents and post-MI medication usage were similar between the 2 groups. Multivariate logistic regression analyses demonstrated that prior MI was a positive independent predictor of occurrence of post-MI angina. Manual thrombectomy use and drug-eluting stent implantation were negative independent predictors of post-MI angina. Higher troponin-I and longer chest pain-to-reperfusion time exhibited a trend toward predicting post-MI angina.Prior MIs were strong, independent predictors of post-MI angina. Manual thrombectomy and drug-eluting

  1. Aspiration Thrombectomy and Drug-Eluting Stent Implantation Decrease the Occurrence of Angina Pectoris One Year After Acute Myocardial Infarction

    PubMed Central

    Lee, Wei-Chieh; Fang, Chih-Yuan; Chen, Huang-Chung; Hsueh, Shu-Kai; Chen, Chien-Jen; Yang, Cheng-Hsu; Yip, Hon-Kan; Hang, Chi-Ling; Wu, Chiung-Jen; Fang, Hsiu-Yu

    2016-01-01

    Abstract Angina pectoris is a treatable symptom that is associated with mortality and decreased quality of life. Angina eradication is a primary care goal of care after an acute myocardial infarction (AMI). Our aim was to evaluate factors influencing angina pectoris 1 year after an AMI. From January 2005 to December 2013, 1547 patient received primary percutaneous intervention in our hospital for an acute ST-segment elevation myocardial infarction (MI). Of these patients, 1336 patients did not experience post-MI angina during a 1-year follow-up, and 211 patients did. Univariate and multivariate logistic regression analyses were performed to identify the factors influencing angina pectoris 1 year after an AMI. Propensity score matched analyses were performed for subgroups analyses. The average age of the patients was 61.08 ± 12.77 years, with a range of 25 to 97 years, and 82.9% of the patients were male. During 1-year follow-up, 13.6% of the patients experienced post-MI angina. There was a longer chest pain-to-reperfusion time in the post-MI angina group (P = 0.01), as well as a higher fasting sugar level, glycohemoglobin (HbA1C), serum creatinine, troponin-I and creatine kinase MB (CK-MB). The post-MI angina group also had a higher prevalence of multiple-vessel disease. Manual thrombectomy, and distal protective device and intracoronary glycoprotein IIb/IIIa inhibitor injection were used frequently in the no post-MI angina group. Antiplatelet agents and post-MI medication usage were similar between the 2 groups. Multivariate logistic regression analyses demonstrated that prior MI was a positive independent predictor of occurrence of post-MI angina. Manual thrombectomy use and drug-eluting stent implantation were negative independent predictors of post-MI angina. Higher troponin-I and longer chest pain-to-reperfusion time exhibited a trend toward predicting post-MI angina. Prior MIs were strong, independent predictors of post-MI angina. Manual thrombectomy

  2. Clinical Outcomes from Unselected "Real-World" Patients with Long Coronary Lesion Receiving 40 mm Biodegradable Polymer Coated Sirolimus-Eluting Stent.

    PubMed

    Polavarapu, Anurag; Polavarapu, Raghava Sarma; Prajapati, Jayesh; Thakkar, Kamlesh; Raheem, Asif; Mayall, Tamanpreet; Thakkar, Ashok

    2015-01-01

    Background. Long lesions being implanted with drug-eluting stents (DES) are associated with relatively high restenosis rates and higher incidences of adverse events. Objectives. We aimed to examine the safety and efficacy of the long (40 mm) biodegradable polymer coated Indolimus sirolimus-eluting stent (SES) in real-world patients with long coronary lesions. Methods. This study was observational, nonrandomized, retrospective, and carried out in real-world patients. A total of 258 patients were enrolled for the treatment of long coronary lesions, with 40 mm Indolimus. The primary endpoints in the study were incidence of major adverse cardiac events (MACE), a miscellany of cardiac death, myocardial infarction (MI), target lesion revascularization (TLR) or target vessel revascularization (TVR), and stent thrombosis (ST) up to 6-month follow-up. Results. The study population included higher proportion of males (74.4%) and average age was 53.2 ± 11.0 years. A total of 278 lesions were intervened successfully with 280 stents. The observed MACE at 6-month follow-up was 2.0%, which included 0.8% cardiac death and 1.2% MI. There were no TLR or TVR and ST observed during 6-month follow-up. Conclusions. The long (40 mm) Indolimus stent demonstrated low MACE rate and was proven to be safe and effective treatment for long lesions in "real-world" patients.

  3. Clinical outcomes with Biolimus (A9)™ eluting stent, 'BioMatrix' in diabetic patients--interim results from multicenter post market surveillance registry in India.

    PubMed

    Seth, Ashok; Hiremath, Shirish; Dani, Sameer; Kapoor, Sunil; Jain, R K; Abhaichand, Rajpal; Trivedi, Shailendra; Kaul, Upendra; Patil, Aruna; Khemnar, Bhushan; Rangnekar, Hrishikesh

    2013-01-01

    The objective of this registry is to establish safety and efficacy of BioMatrix, BioMatrix™-Biolimus A9™ eluting stent in diabetic population in India. Diabetes mellitus is a major predisposing factor for coronary artery disease. Prognosis for diabetic population patients presenting with coronary artery disease who undergo coronary revascularization is inferior to non diabetics and remains an independent risk factor of restenosis, need for revascularization, and overall mortality. Stent thrombosis is a potential complication of first generation, permanent polymer drug-eluting stents. Biodegradable polymer is a good relief in this era and its utility in diabetic patients will be a major advantage for them. 334 patients with diabetes mellitus and requiring angioplasty, implanted with BioMatrix stent were followed at 1, 6, 12 and 24 months who entered in a multicenter registry in India. We analyzed the incidence of major adverse cardiac events (MACE) and stent thrombosis (ST) at 1, 6, 12 and 24 months. The mean age was 58.71 ± 9.2 years, 81% were males, comorbidity index was 1.6 ± 1.02, and 59.1% presented with acute coronary syndrome. The incidence of adverse event rates was: MACE 1.27%. There were no incidences of myocardial infarction (MI) and target vessel revascularization (TVR). Definite stent thrombosis occurred only in 2 patients. In this registry of diabetic population treated with BioMatrixTM-Biolimus A9TM eluting stent (BioMatrix), the reported incidence of MACE and ST were much lower than previously published results. The 1- and 2-year follow-up result supports favorable clinical outcomes of using BioMatrix stents as a suitable alternative to contemporary DES available during PCI in diabetic patients. Copyright © 2013 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  4. Prevalence and impact of high platelet reactivity in chronic kidney disease: results from the Assessment of Dual Antiplatelet Therapy with Drug-Eluting Stents registry.

    PubMed

    Baber, Usman; Mehran, Roxana; Kirtane, Ajay J; Gurbel, Paul A; Christodoulidis, Georgios; Maehara, Akiko; Witzenbichler, Bernhard; Weisz, Giora; Rinaldi, Michael J; Metzger, D Christopher; Henry, Timothy D; Cox, David A; Duffy, Peter L; Mazzaferri, Ernest L; Xu, Ke; Parise, Helen; Brodie, Bruce R; Stuckey, Thomas D; Stone, Gregg W

    2015-06-01

    Chronic kidney disease (CKD) is associated with increased rates of adverse events after percutaneous coronary intervention. We sought to determine the impact of CKD on platelet reactivity in clopidogrel-treated patients and whether high platelet reactivity (HPR) confers a similar or differential risk for adverse events among patients with CKD and non-CKD. We performed a post hoc analysis of the Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents (ADAPT-DES) registry, which included 8582 patients undergoing percutaneous coronary intervention with drug-eluting stents and platelet function testing using the VerifyNow assay. We compared HPR and its impact on ischemic and bleeding events >2 years among patients with CKD and non-CKD. Patients with CKD (n=1367) were older, more often female, diabetic, and had lower ejection fraction compared with their non-CKD counterparts (n=7043). Although HPR prevalence increased with worsening renal function in unadjusted analyses, these associations were no longer present after adjustment. Major adverse cardiac event rates at 2 years among those without CKD or HPR, HPR alone, CKD alone, and both CKD and HPR were 9.0%, 11.2%, 13.3%, and 17.5%, respectively (P<0.001). Associations between HPR and adverse events were uniform across CKD strata without evidence of interaction. HPR is more common among those with versus without CKD, an association that is attributable to confounding risk factors that are more prevalent in CKD. The impact of HPR on ischemic and bleeding events is similar irrespective of CKD status. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00638794. © 2015 American Heart Association, Inc.

  5. Comparison between imported versus domestic drug-eluting stents in China: A large single-center data.

    PubMed

    Liu, Ru; Gao, Zhan; Chen, Jue; Gao, Lijian; Song, Lei; Qiao, Shubin; Yang, Yuejin; Gao, Runlin; Xu, Bo; Yuan, Jinqing

    2017-08-01

    In recent years, most drug-eluting stents (DESs) were domestically produced in China, but how domestic DESs perform compared to imported DESs was still unknown. A total of 9011 consecutive cases with DESs implantation in a single center throughout 2013 were prospectively collected. Two-year clinical outcomes were evaluated between patients implanted with imported and domestic DESs. During 2-year follow-up, the rates of all-cause death, cardiac death, myocardial infarction, stroke, and stent thrombosis were not significantly different between two groups. However, the rate of revascularization was significantly higher in domestic DES group, shown as higher rates of overall revascularization, target vessel revascularization (TVR), and target lesion revascularization (TLR) (9.7% vs 6.4%, P < 0.001; 5.6% vs 3.2%, P < 0.001; 4.5% vs 2.2%, P < 0.001, respectively). Accordingly, major adverse cardiac events (MACE) rate was significantly higher in domestic DES group (12.1% vs 8.5%, P < 0.001). Multivariable Cox regression analysis indicated that domestic DES was an independent risk factor of MACE (HR [95%CI]: 1.22 [1.05-1.41]), overall revascularization (HR [95%CI]: 1.29 [1.09-1.53]), TVR (HR [95%CI]: 1.54 [1.22-1.94]), and TLR (HR [95%CI]: 1.85 [1.41-2.42]). After propensity score matching, the rates of overall revascularization, TVR, and TLR were still significantly higher in domestic DES group, and domestic DES was still predictive of overall revascularization, TVR, and TLR in multivariate Cox regression analysis. Domestic DESs showed the same safety as imported DESs in this real-world cohort. But, patients implanted with domestic DESs had a higher risk of revascularization than imported DESs. © 2017, Wiley Periodicals, Inc.

  6. Impact of Anemia on Platelet Reactivity and Ischemic and Bleeding Risk: From the Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents Study.

    PubMed

    Giustino, Gennaro; Kirtane, Ajay J; Baber, Usman; Généreux, Philippe; Witzenbichler, Bernhard; Neumann, Franz-Josef; Weisz, Giora; Maehara, Akiko; Rinaldi, Michael J; Metzger, Christopher; Henry, Timothy D; Cox, David A; Duffy, Peter L; Mazzaferri, Ernest L; Brodie, Bruce R; Stuckey, Thomas D; Gurbel, Paul A; Dangas, George D; Francese, Dominic P; Ozan, Ozgu; Mehran, Roxana; Stone, Gregg W

    2016-06-15

    Anemic patients remain at increased risk of ischemic and bleeding events. Whether the effects of hemoglobin levels on thrombotic and bleeding risk are independent of platelet reactivity on clopidogrel, however, remains unknown. Patients from the Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents study were categorized by the presence of anemia at baseline, defined according the World Health Organization criteria. Platelet reactivity was measured with VerifyNow assay; high platelet reactivity (HPR) on clopidogrel was defined as platelet reactive units value >208. Of 8,413 patients included in the study cohort, 1,816 (21.6%) had anemia. HPR was more prevalent in patients with anemia (58.3% vs 38.4%; p <0.001), an association that persisted after multivariate adjustment (adjusted odds ratio: 2.04; 95% confidence interval [CI]: 1.82 to 2.29; p <0.0001). Patients with anemia had higher 2-year rates of major adverse cardiac events (9.5% vs 5.6%; p <0.0001), major bleeding (11.8% vs 7.7%; p <0.0001), and all-cause mortality (4.0% vs 1.4%; p <0.0001); however, after adjustment for baseline clinical confounders, including HPR, anemia was no longer significantly associated with major adverse cardiac events but was still independently associated with all-cause mortality (adjusted HR 1.61, 95% CI 1.23 to 2.12; p <0.0001) and major bleeding (adjusted HR 1.42, 95% CI 1.20 to 1.68; p <0.0001). The effect of HPR on clinical outcomes was uniform according to anemia status, without evidence of interaction. In conclusion, anemia independently correlated with HPR. After percutaneous coronary intervention with drug-eluting stents, anemia at baseline was significantly associated with higher 2-year hemorrhagic and mortality risk; conversely, its association with ischemic risk was attenuated after multivariate adjustment, including HPR. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Preclinical evaluation of a novel abluminal surface coated sirolimus eluting stent with biodegradable polymer matrix

    PubMed Central

    Doshi, Manish; Galloni, Marco; Vignolini, Christina; Vyas, Ashwin; Chevli, Bhavesh; Sheiban, Imad

    2015-01-01

    Background Second generation of drug eluting stents (DES) has attempted to improve safety using abluminal sirolimus drug delivery with biodegradable polymers matrix. The present preclinical study was designed to investigate the safety and efficacy profile of Abluminus™ stents (SES). This is a new coronary stent with sirolimus and biodegradable polymer matrix coated on abluminal stent and balloon surface. Methods SES were compared with two controls: bare metal stent (BMS) and BMS + polymer coated stents (PC). All devices (40 stents) were implanted in porcine coronary arteries with primary endpoint of endothelialization at 7 days and subsequent histological and morphometric evaluations at 7, 30 and 90 days. Results Early endothelialization at seven days was complete in all stents. Histology at 30 days revealed minimum inflammation in all groups and increased at 90 days in PC group while it was absent at 180 days. Thirty day morphometry showed significantly reduction of neointimal area in Abluminus™ (SES 0.96±0.48 mm2; BMS 1.83±0.34 mm2; PC 1.76±0.55 mm2; P<0.05); after 90 days neointimal area was 1.10±0.54 mm2 for SES; 1.92±0.36 mm2 for BMS; and 1.94±0.48 mm2 for PC; P<0.05). Neointimal thickness at 30 and 90 days respectively was 0.15±0.07 and 0.18±0.10 mm for SES, 0.57±0.08 and 0.61±0.09 mm for BMS and 0.52±0.09 and 0.59±0.08 mm, P<0.001 for PC group. Conclusions The most significant experimental evidence appears to be earlier endothelialization at 7 days for SES which led to safety of the device. Efficacy of the device was also observed by a reduced neointimal thickness and minimized inflammatory score at all follow-ups. Termination of antiplatelet at 30 days has not shown any further complications. Polymer thickness was almost in negligible amount at 180 days with no inflammation. PMID:26331109

  8. Association Between Helicobacter Pylori Infection and Long-term Outcome in Patients with Drug-eluting Stent Implantation

    NASA Astrophysics Data System (ADS)

    Wang, Rui; Chen, Lei-Lei; Wang, De-Zhao; Chen, Bu-Xing

    2017-07-01

    To investigate the relationship between Helicobacter pylori (Hp) infection and the long-term outcome in acute coronary syndrome (ACS) patients with drug-eluting stent (DES) implantation and so as to explore the significance of Hp eradication therapy in preventing major adverse cardiac events (MACE) and upper gastrointestinal bleeding (UGIB). 539 ACS patients with DES implantation from January 1, 2010 to December 31, 2012 were analyzed. All the patients were divided into two groups according to the result of 13C urea breath test. 253 patients with Hp infection were put into group A (Hp+), and 286 cases without Hp infection were put into group B (Hp-). Demographic data was collected and all patients went through biochemical indicators and other routine blood examinations. We explored the correlations of Hp infection with MACE and UGIB after 3 to 5 years of follow-up using survival analysis. Survival analysis showed that Hp infection was a predictor of MACE and UGI. Sub-group analysis showed that patients with Hp eradication therapy had no relationship with MACE but had a lower rate of UGIB than those without Hp eradication therapy.

  9. Meta-analysis of long-term clinical outcomes of everolimus-eluting stents.

    PubMed

    Toyota, Toshiaki; Shiomi, Hiroki; Morimoto, Takeshi; Kimura, Takeshi

    2015-07-15

    The superiority of everolimus-eluting stents (EES) over sirolimus-eluting stents (SES) for long-term clinical outcomes has not been yet firmly established. We conducted a systematic review and a meta-analysis of randomized controlled trials (RCTs) comparing EES directly with SES using the longest available follow-up data. We searched PubMed, the Cochrane database, and ClinicalTrials.gov for RCTs comparing outcomes between EES and SES and identified 13,434 randomly assigned patients from 14 RCTs. EES was associated with significantly lower risks than SES for definite stent thrombosis (ST), definite/probable ST, target-lesion revascularization (TLR), and major adverse cardiac events (MACE). The risks for all-cause death and myocardial infarction were similar between EES and SES. By the stratified analysis according to the timing after stent implantation, the favorable trend of EES relative to SES for ST, TLR, and MACE was consistently observed both within and beyond 1 year. The lower risk of EES relative to SES for MACE beyond 1 year was statistically significant (pooled odds ratio 0.77, 95% confidence interval 0.61 to 0.96, p = 0.02). In conclusion, the current meta-analysis of 14 RCTs directly comparing EES with SES suggested that EES provided improvement in both safety and efficacy; EES compared with SES was associated with significantly lower risk for definite ST, definite/probable ST, TLR, and MACE. The direction and magnitude of the effect beyond 1 year were comparable with those observed within 1 year. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Drug Eluting Stents for Malignant Airway Obstruction: A Critical Review of the Literature

    PubMed Central

    Hohenforst-Schmidt, Wolfgang; Zarogoulidis, Paul; Pitsiou, Georgia; Linsmeier, Bernd; Tsavlis, Drosos; Kioumis, Ioannis; Papadaki, Eleni; Freitag, Lutz; Tsiouda, Theodora; Turner, J Francis; Browning, Robert; Simoff, Michael; Sachpekidis, Nikolaos; Tsakiridis, Kosmas; Zaric, Bojan; Yarmus, Lonny; Baka, Sofia; Stratakos, Grigoris; Rittger, Harald

    2016-01-01

    Lung cancer being the most prevalent malignancy in men and the 3rd most frequent in women is still associated with dismal prognosis due to advanced disease at the time of diagnosis. Novel targeted therapies are already on the market and several others are under investigation. However non-specific cytotoxic agents still remain the cornerstone of treatment for many patients. Central airways stenosis or obstruction may often complicate and decrease quality of life and survival of these patients. Interventional pulmonology modalities (mainly debulking and stent placement) can alleviate symptoms related to airways stenosis and improve the quality of life of patients. Mitomycin C and sirolimus have been observed to assist a successful stent placement by reducing granuloma tissue formation. Additionally, these drugs enhance the normal tissue ability against cancer cell infiltration. In this mini review we will concentrate on mitomycin C and sirolimus and their use in stent placement. PMID:26918052

  11. New-generation stents compared with coronary bypass surgery for unprotected left main disease: A word of caution.

    PubMed

    Benedetto, Umberto; Taggart, David P; Sousa-Uva, Miguel; Biondi-Zoccai, Giuseppe; Di Franco, Antonino; Ohmes, Lucas B; Rahouma, Mohamed; Kamel, Mohamed; Caputo, Massimo; Girardi, Leonard N; Angelini, Gianni D; Gaudino, Mario

    2018-05-01

    With the advent of bare metal stents and drug-eluting stents, percutaneous coronary intervention has emerged as an alternative to coronary artery bypass grafting surgery for unprotected left main disease. However, whether the evolution of stents technology has translated into better results after percutaneous coronary intervention remains unclear. We aimed to compare coronary artery bypass grafting with stents of different generations for left main disease by performing a Bayesian network meta-analysis of available randomized controlled trials. All randomized controlled trials with at least 1 arm randomized to percutaneous coronary intervention with stents or coronary artery bypass grafting for left main disease were included. Bare metal stents and drug-eluting stents of first- and second-generation were compared with coronary artery bypass grafting. Poisson methods and Bayesian framework were used to compute the head-to-head incidence rate ratio and 95% credible intervals. Primary end points were the composite of death/myocardial infarction/stroke and repeat revascularization. Nine randomized controlled trials were included in the final analysis. Six trials compared percutaneous coronary intervention with coronary artery bypass grafting (n = 4654), and 3 trials compared different types of stents (n = 1360). Follow-up ranged from 6 months to 5 years. Second-generation drug-eluting stents (incidence rate ratio, 1.3; 95% credible interval, 1.1-1.6), but not bare metal stents (incidence rate ratio, 0.63; 95% credible interval, 0.27-1.4), and first-generation drug-eluting stents (incidence rate ratio, 0.85; 95% credible interval, 0.65-1.1) were associated with a significantly increased risk of death/myocardial infarction/stroke when compared with coronary artery bypass grafting. When compared with coronary artery bypass grafting, the highest risk of repeat revascularization was observed for bare metal stents (hazard ratio, 5.1; 95% confidence interval, 2

  12. Stents: Biomechanics, Biomaterials, and Insights from Computational Modeling.

    PubMed

    Karanasiou, Georgia S; Papafaklis, Michail I; Conway, Claire; Michalis, Lampros K; Tzafriri, Rami; Edelman, Elazer R; Fotiadis, Dimitrios I

    2017-04-01

    Coronary stents have revolutionized the treatment of coronary artery disease. Improvement in clinical outcomes requires detailed evaluation of the performance of stent biomechanics and the effectiveness as well as safety of biomaterials aiming at optimization of endovascular devices. Stents need to harmonize the hemodynamic environment and promote beneficial vessel healing processes with decreased thrombogenicity. Stent design variables and expansion properties are critical for vessel scaffolding. Drug-elution from stents, can help inhibit in-stent restenosis, but adds further complexity as drug release kinetics and coating formulations can dominate tissue responses. Biodegradable and bioabsorbable stents go one step further providing complete absorption over time governed by corrosion and erosion mechanisms. The advances in computing power and computational methods have enabled the application of numerical simulations and the in silico evaluation of the performance of stent devices made up of complex alloys and bioerodible materials in a range of dimensions and designs and with the capacity to retain and elute bioactive agents. This review presents the current knowledge on stent biomechanics, stent fatigue as well as drug release and mechanisms governing biodegradability focusing on the insights from computational modeling approaches.

  13. Drug-eluting coating of ginsenoside Rg1 and Re incorporated poly(lactic-co-glycolic acid) on stainless steel 316L: Physicochemical and drug release analyses.

    PubMed

    Miswan, Zulaika; Lukman, Siti Khadijah; Abd Majid, Fadzilah Adibah; Loke, Mun Fai; Saidin, Syafiqah; Hermawan, Hendra

    2016-12-30

    Active ingredients of ginsenoside, Rg1 and Re, are able to inhibit the proliferation of vascular smooth muscle cells and promote the growth of vascular endothelial cells. These capabilities are of interest for developing a novel drug-eluting stent to potentially solve the current problem of late-stent thrombosis and poor endotheliazation. Therefore, this study was aimed to incorporate ginsenoside into degradable coating of poly(lactic-co-glycolic acid) (PLGA). Drug mixture composed of ginseng extract and 10% to 50% of PLGA (xPLGA/g) was coated on electropolished stainless steel 316L substrate by using a dip coating technique. The coating was characterized principally by using attenuated total reflectance-Fourier transform infrared spectroscopy, scanning electron microscopy and contact angle analysis, while the drug release profile of ginsenosides Rg1 and Re was determined by using mass spectrometry at a one month immersion period. Full and homogenous coating coverage with acceptable wettability was found on the 30PLGA/g specimen. All specimens underwent initial burst release dependent on their composition. The 30PLGA/g and 50PLGA/g specimens demonstrated a controlled drug release profile having a combination of diffusion- and swelling-controlled mechanisms of PLGA. The study suggests that the 30PLGA/g coated specimen expresses an optimum composition which is seen as practicable for developing a controlled release drug-eluting stent. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Sex differences in the effect of diabetes mellitus on platelet reactivity and coronary thrombosis: From the Assessment of Dual Antiplatelet Therapy with Drug-Eluting Stents (ADAPT-DES) study.

    PubMed

    Giustino, Gennaro; Redfors, Björn; Mehran, Roxana; Kirtane, Ajay J; Baber, Usman; Généreux, Philippe; Witzenbichler, Bernhard; Neumann, Franz-Josef; Weisz, Giora; Maehara, Akiko; Rinaldi, Michael J; Metzger, D Christopher; Henry, Timothy D; Cox, David A; Duffy, Peter L; Mazzaferri, Ernest L; Brodie, Bruce R; Stuckey, Thomas D; Dangas, George D; Brener, Sorin J; Ozgu Ozan, M; Stone, Gregg W

    2017-11-01

    Whether the consequences of diabetes mellitus (DM) are worse for women than for men treated with drug-eluting stents (DES) and antiplatelet therapy remain unclear. Patients from the Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents study were stratified according to sex and DM status. We investigated the sex-specific effect of DM on high on-clopidogrel platelet reactivity (HPR), defined as a P2Y 12 reaction units ≥208, and the adjusted association of DM on the 2-year risk for coronary thrombotic events (CTE), defined as spontaneous myocardial infarction or definite or probable stent thrombosis. Out of 8582 patients included in the study, 829 were women with DM (9.6%) and 1954 were men with DM (16.2%). The prevalence of insulin-treated DM (ITDM) was greater in women (p<0.0001). By multivariable logistic regression, DM was associated with a greater likelihood of HPR that was uniform between sexes (p int =0.88). Following adjustment for baseline variables and HPR, in women a stepwise increase in risk for CTEs was observed in the transition from no DM to non-ITDM (NITDM) (adjusted hazard ratio [adjHR]: 1.31; 95% CI: 0.78-2.18) to ITDM (adjHR: 2.69; 95% CI: 1.23-3.45). This increase in risk associated with subtypes of DM was of smaller magnitude in men (for NITDM, adjHR: 1.04; 95% CI: 0.77-1.39; for ITDM, adjHR: 1.46; 95% CI: 1.05-2.03; p int =0.016). In a population treated with DES and antiplatelet therapy, the risk for CTE associated with DM seems to be greater in women and was independent of HPR. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Anti-Inflammatory Effect of Gallic Acid-Eluting Stent in a Porcine Coronary Restenosis Model

    PubMed Central

    Seob Lim, Kyung; Park, Jun-Kyu; Ho Jeong, Myung; Ho Bae, In; Sung Park, Dae; Won Shim, Jae; Ha Kim, Jung; Kuk Kim, Hyun; Soo Kim, Sung; Sun Sim, Doo; Joon Hong, Young; Han Kim, Ju; Ahn, Youngkeun

    2018-01-01

    Background Gallic acid (3,4,5-trihydroxybenzoic acid) is a natural polyphenol and strong natural antioxidant found abundantly in red wine and green tea. The aim of this study was to examine the anti-inflammatory effect of a novel gallic acid-eluting stent in a porcine coronary restenosis model. Methods Fifteen pigs were randomized into three groups; in which a total of 30 coronary arteries (10 in each group) were implanted with gallic acid-eluting stents (GESs, n = 10), gallic acid and sirolimus-eluting stents (GSESs, n = 10), or sirolimus-eluting stents (SESs, n = 10). Histopathologic analysis was performed 28 days after stenting. Results There were no significant differences in injury score and fibrin score among the groups, however there were significant differences in the internal elastic lamina (4.0 ± 0.83 mm2 in GES vs. 3.0 ± 0.53 mm2 in GSES vs. 4.6 ± 1.43 mm2 in SES, p < 0.0001), lumen area (2.3 ± 0.49 mm2 in GES vs. 1.9 ± 0.67 mm2 in GSES vs. 2.9 ± 0.56 mm2 in SES, p < 0.0001), neointimal area (1.7 ± 0.63 mm2 in GES vs. 1.1 ± 0.28 mm2 in GSES vs. 1.7 ± 1.17 mm2 in SES, p < 0.05), and percent area of stenosis (42.4% ± 9.22% in GES vs. 38.2% ± 12.77% in GSES vs. 33.9% ± 15.64% in SES, p < 0.05). The inflammation score was significantly lower in the GES and GSES groups compared to that in the SES group [1.0 (range: 1.0 to 2.0) in GES vs. 1.0 (range: 1.0 to 1.0) in GSES vs. 1.5 (range: 1.0 to 3.0) in SES, p < 0.05]. Conclusions The GES group had a greater percent area of stenosis than the SES group. Although gallic acid in the GES and GSES groups did not show a synergistic effect in suppressing neointimal hyperplasia, it resulted in greater inhibition of the inflammatory reaction in the porcine coronary restenosis model than in the SES group. PMID:29844643

  16. A break-even price calculation for the use of sirolimus-eluting stents in angioplasty.

    PubMed

    Galanaud, Jean-Philippe; Delavennat, Juliette; Durand-Zaleski, Isabelle

    2003-03-01

    One of the major complications of angioplasty is the early occurrence of restenosis requiring a repeat procedure. When bare-metal stents are used, clinical restenosis results in a repeat procedure in 10% to 15% of cases. Based on the results of an international, randomized clinical trial, the use of sirolimus-eluting stents reduces this risk. The aims of this study were to calculate the theoretical break-even price for sirolimus-eluting stents in France, the Netherlands, and the United States, and to determine the additional health care cost per patient. The break-even price was calculated by adding the savings resulting from a 15% decrease in the rate of clinical restenosis to the price of bare-metal stents. Costs were computed from the viewpoint of the health care system, exclusive of other societal costs. The break-even prices were 1291 Euro to 1489 Euro in France, 2028 Euro in the Netherlands, and 2708 Euroin the United States (1.00 Euro = 1.00 US dollar in purchasing power parity). These results indicate that the commercial price of sirolimuseluting stents will increase hospital spending for patients undergoing angioplasty by 17% to 55% per patient. This additional cost to the health care system should be discussed in view of possible productivity savings and improved quality of life for patients.

  17. The short- and long-term outcomes of percutaneous intervention with drug-eluting stent vs bare-metal stent in saphenous vein graft disease: An updated meta-analysis of all randomized clinical trials.

    PubMed

    Kheiri, Babikir; Osman, Mohammed; Abdalla, Ahmed; Ahmed, Sahar; Bachuwa, Ghassan; Hassan, Mustafa

    2018-05-11

    The use of drug-eluting stents (DES) vs bare-metal stents (BMS) in saphenous vein graft (SVG) lesions remains controversial. We conducted a meta-analysis of all randomized clinical trials comparing the outcomes of DES with BMS in SVG percutaneous coronary interventions. A search of PubMed, Embase, the Cochrane Register of Controlled Trials, and Clinicaltrials.gov was performed for all randomized clinical trials. We evaluated the short- and long-term clinical outcomes of the following: all-cause mortality, major adverse cardiovascular events (MACE), definite/probable stent thrombosis, target lesion revascularization (TLR), and target-vessel revascularization (TVR). From a total of 1582 patients in 6 randomized clinical trials, 797 had DES and 785 had BMS. Patients with DES had lower short-term MACE, TLR, and TVR in comparison with BMS (odds ratio [OR]: 0.56, 95% confidence interval [CI]: 0.35-0.91, P = 0.02; OR: 0.43, 95% CI: 0.19-0.99, P = 0.05; and OR: 0.45, 95% CI: 0.22-0.95, P = 0.04, respectively). However, there were no different outcomes for all-cause mortality (P = 0.63) or stent thrombosis (P = 0.21). With long-term follow-up, there were no significant reductions of MACE (P = 0.20), TLR (P = 0.57), TVR (P = 0.07), all-cause mortality (P = 0.29), and stent thrombosis (P = 0.76). The use of DES in SVG lesions was associated with lower short-term MACE, TLR, and TVR in comparison with BMS. However, there were no significant differences with long-term follow-up. © 2018 Wiley Periodicals, Inc.

  18. Comparative assessment of three drug eluting stents with different platforms but with the same biodegradable polymer and the drug based on quantitative coronary angiography and optical coherence tomography at 12-month follow-up.

    PubMed

    Gil, Robert J; Bil, Jacek; Legutko, Jacek; Pawłowski, Tomasz; Gil, Katarzyna E; Dudek, Dariusz; Costa, Ricardo A

    2018-03-01

    The aim of this study was to compare neointima proliferation in three drug-eluting stents (DES) produced by the same company (Balton, Poland) which are covered with a biodegradable polymer and elute sirolimus (concentration: 1.0 and 1.2 µg/mm 2 ), but have different stent platforms and strut thickness: stainless steel Prolim ® (115 µm) and BiOSS LIM ® (120 µm) and cobalt-chromium Alex ® (70 µm). We analyzed data of patients with quantitative coronary angiography (QCA) and optical coherence tomography (OCT) at 12 months from BiOSS LIM Registry, Prolim Registry and Alex OCT clinical trial. There were 56 patients enrolled, in whom 29 Prolim ® stents were deployed, in 11-BiOSS LIM ® and in 16-Alex stents. The late lumen loss was the smallest in Prolim ® subgroup (0.26 ± 0.17 mm) and did not differ from Alex ® subgroup (0.28 ± 0.47 mm). This parameter was significantly bigger in BiOSS ® subgroup (0.38 ± 0.19 mm; p < 0.05). In OCT analysis there was no statistically significant difference between Prolim ® and Alex ® subgroups in terms of mean neointima burden (24.6 ± 8.6 vs. 19.27 ± 8.11%) and neointima volume (28.16 ± 15.10 vs. 24.51 ± 17.64 mm 3 ). In BiOSS ® group mean neointima burden (30.9 ± 6.2%) and mean neointima volume (44.9 ± 4.9 mm 3 ) were significantly larger. The morphological analysis revealed that in most cases in all groups the neointima was homogenous with plaque presence only around stent struts. In the QCA and OCT analysis regular DES (Prolim ® and Alex ® ) obtained similar results, whereas more pronounced response from the vessel wall was found in the BiOSS ® subgroup.

  19. Porous TiO₂ surface formed on nickel-titanium alloy by plasma electrolytic oxidation: a prospective polymer-free reservoir for drug eluting stent applications.

    PubMed

    Huan, Zhiguang; Fratila-Apachitei, Lidy E; Apachitei, Iulian; Duszczyk, Jurek

    2013-07-01

    In this study, a porous oxide layer was formed on the surface of nickel-titanium alloy (NiTi) by plasma electrolytic oxidation (PEO) with the aim to produce a polymer-free drug carrier for drug eluting stent (DES) applications. The oxidation was performed galvanostatically in concentrated phosphoric acid electrolyte at low temperature. It was found that the response of NiTi substrate during the PEO process was different from that of bulk Ti, since the presence of large amount of Ni delayed the initial formation of a compact oxide layer that is essential for the PEO to take place. Under optimized PEO conditions, the resultant surface showed porosity, pore density and oxide layer thickness of 14.11%, 2.40 × 10⁵ pores/mm² and 0.8 μm, respectively. It was additionally noted that surface roughness after PEO did not significantly increase as compared with that of original NiTi substrate and the EDS analyses revealed a decrease in Ni/Ti ratio on the surface after PEO. The cross-section morphology showed no discontinuity between the PEO layer and the NiTi substrate. Furthermore, wettability and surface free energy of the NiTi substrate increased significantly after PEO treatment. The PEO process could be successfully translated to NiTi stent configuration proving for the first time its feasibility for such a medical device and offering potential for development of alternative, polymer-free drug carriers for NiTi DES. Copyright © 2013 Wiley Periodicals, Inc.

  20. Surface characterization of polymer-drug modified vascular stents and intraocular lenses

    NASA Astrophysics Data System (ADS)

    Elachchabi, Amin

    Two of the most important medical devices in clinical use today are endoluminal stents and intraocular lenses (IOLs). In both devices, surface and interfacial properties are of basic importance in the development and clinical performance of these devices. Drug eluting stents have revolutionized the world of interventional cardiology. Research reported here was devoted to the design and development of new drug eluting stents wherein the metallic backbone is completely embedded in a polymeric matrix used also as a drug reservoir. This design, using silicone-drug compositions can lead to higher drug payloads, less tissue damage during angioplasty balloon/stent expansion, and the novel capability of delivering multiple drugs. The adhesion of the polymeric coating to the metallic stent is essential and has not been adequately reported previously. The adhesion of polydimethylsiloxane (PDMS) coatings to a stainless steel stent substrate was shown to be enhanced by the application of mixtures of tetra-n-propyl silicate, tetrabutyltitanate, tetra-2-methoxyethoxysilane, and 3-(trimethoxysilyl)propyl methacrylate coupling agents. Additionally, the effect of drug loading on the stress/strain properties of the polymeric coating is of basic importance. The tensile strength and percent elongation of dexamethasone loaded PDMS films was shown to remain satisfactory for stent coatings at low concentrations (less than 1%) but decreased as the concentrations of dexamethasone in PDMS was increased to 5%. The release of multiple therapeutic agents from PDMS coatings to reduce in-stent restenosis has not been previously reported. The release profile of Paclitaxel, dexamethasone 21-acetate, and their combination from PDMS coatings was studied using high precision liquid chromatography (HPLC). Although dexamethasone release was reduced by paclitaxel, paclitaxel release was unaffected by combination with dexamethasone. Paclitaxel release from the polymeric matrices was shown to inhibit

  1. Angioplasty and stent - heart - discharge

    MedlinePlus

    Drug-eluting stents - discharge; PCI - discharge; Percutaneous coronary intervention - discharge; Balloon angioplasty - discharge; Coronary angioplasty - discharge; Coronary artery angioplasty - discharge; Cardiac ...

  2. Study protocol for a randomised controlled trial: harmonising optimal strategy for treatment of coronary artery stenosis - coronary intervention with next-generation drug-eluting stent platforms and abbreviated dual antiplatelet therapy (HOST-IDEA) trial.

    PubMed

    Kim, Chi-Hoon; Han, Jung-Kyu; Yang, Han-Mo; Park, Kyung Woo; Lee, Hae-Young; Kang, Hyun-Jae; Koo, Bon-Kwon; Lee, Namho; Cha, Tae-Joon; Yang, Tae-Hyun; Jeong, Myung-Ho; Yoon, Myeong-Ho; Lee, Seung Uk; Lee, Seung Jin; Kim, Jin Won; Cho, Jin-Man; Han, Kyoo-Rok; Pyun, Wook Bum; Kim, Hyo-Soo

    2017-10-11

    We have recently seen the introduction of newer generation drug-eluting stents with ultrathin struts that use advanced polymer technologies. However, the efficacy and safety of these newest stents have not yet been fully explored. In addition, there are still controversies over the optimal duration of dual antiplatelet therapy (DAPT) after stent implantation, particularly for ultrathin stents with the newest polymer technologies. The HOST-IDEA trial is a randomised, open-label, multicentre, non-inferiority trial and the first study to directly compare two of these ultrathin sirolimus-eluting stents: Orsiro stent with biodegradable polymer, and polymer-free Coroflex ISAR (CX-ISAR) stent. This study has a scheme of 2×2 factorial design according to the stent type and DAPT duration (3 vs 12 months). A total of 2152 patients will be randomised and stratified to demonstrate the non-inferiority of CX-ISAR to Orsiro, or of the abbreviated DAPT duration to the conventional 12 months (both in 1:1 ratio). For the comparison of stent type, the primary endpoint is target lesion failure (TLF), which is a composite of cardiac death, target vessel-related myocardial infarction and clinically driven target lesion revascularisation. For the comparison of DAPT duration, the net adverse clinical event is the coprimary endpoint, which is defined as a composite of TLF, definite/probable stent thrombosis and major bleeding. All the institutions involved in this study are required to have ethical approval prior to patient enrolment. This multicentre study will recruit patients through competitive registration, but institutions that have not yet obtained ethical approvals have made it impossible to enrol patients in a centralised web database. The final results will be presented at relevant international conferences and will be materialised in the form of papers. NCT02601157; Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article

  3. Long-term clinical and angiographic results of Sirolimus-Eluting Stent in Complex Coronary Chronic Total Occlusion Revascularization: the SECTOR registry.

    PubMed

    Galassi, Alfredo R; Tomasello, Salvatore D; Costanzo, Luca; Campisano, Maria B; Barrano, Giombattista; Tamburino, Corrado

    2011-10-01

    Drug-eluting stents showed a better angiographic and clinical outcome in comparison with bare metal stent in chronic total occlusions (CTOs) percutaneous revascularization, however, great concerns still remain regarding the rate of restenosis and reocclusion in comparison with nonocclusive lesions. To evaluate angiographic and clinical outcomes after sirolimus-eluting stent (SES) implantation in the setting of a "real world" series of complex CTOs. From January 2006 to December 2008, 172 consecutive patients with 179 CTO lesions were enrolled into registry. Among these, successful recanalization was obtained in 144 lesions (80.4%) with exclusive SES implantation in 104 lesions. The 9-12 months angiographic follow-up was executed in 85.5% of lesions with evidence of angiographic binary restenosis in 16.8% of lesions. Total stent length and number of stent implanted were recognized as independent predictors of restenosis (odds ratio [OR] 4.7, 95% confidence interval [CI] 1.28-107.09, P = 0.02) and (OR 5.8, 95% CI 1.39-23.55, P = 0.01), respectively.The 2-year clinical follow-up showed rates of target lesion revascularization, non-Q wave myocardial infarction, and total major adverse cardiovascular events (MACEs) of 11.1%, 2%, and 13.1%, respectively. Cox proportional-hazard analysis showed diabetes as independent predictor of MACEs (hazard ratio [HR] 4.832; 95% CI, 0.730-0.861; P = 0.028). Data from this registry demonstrate the long-term efficacy and safety of SES implantation after complex CTOs recanalization. ©2011, Wiley Periodicals, Inc.

  4. Clinical outcomes with Biolimus (A9)™ eluting stent, ‘BioMatrix’ in diabetic patients – interim results from multicenter post market surveillance registry in India

    PubMed Central

    Seth, Ashok; Hiremath, Shirish; Dani, Sameer; Kapoor, Sunil; Jain, R.K.; Abhaichand, Rajpal; Trivedi, Shailendra; Kaul, Upendra; Patil, Aruna; Khemnar, Bhushan; Rangnekar, Hrishikesh

    2013-01-01

    Objective The objective of this registry is to establish safety and efficacy of BioMatrix, BioMatrix™-Biolimus A9™ eluting stent in diabetic population in India. Background Diabetes mellitus is a major predisposing factor for coronary artery disease. Prognosis for diabetic population patients presenting with coronary artery disease who undergo coronary revascularization is inferior to non diabetics and remains an independent risk factor of restenosis, need for revascularization, and overall mortality. Stent thrombosis is a potential complication of first generation, permanent polymer drug-eluting stents. Biodegradable polymer is a good relief in this era and its utility in diabetic patients will be a major advantage for them. Methods 334 patients with diabetes mellitus and requiring angioplasty, implanted with BioMatrix stent were followed at 1, 6, 12 and 24 months who entered in a multicenter registry in India. We analyzed the incidence of major adverse cardiac events (MACE) and stent thrombosis (ST) at 1, 6, 12 and 24 months. Results The mean age was 58.71 ± 9.2 years, 81% were males, comorbidity index was 1.6 ± 1.02, and 59.1% presented with acute coronary syndrome. The incidence of adverse event rates was: MACE 1.27%. There were no incidences of myocardial infarction (MI) and target vessel revascularization (TVR). Definite stent thrombosis occurred only in 2 patients. Conclusion In this registry of diabetic population treated with BioMatrixTM-Biolimus A9TM eluting stent (BioMatrix), the reported incidence of MACE and ST were much lower than previously published results. The 1- and 2-year follow-up result supports favorable clinical outcomes of using BioMatrix stents as a suitable alternative to contemporary DES available during PCI in diabetic patients. PMID:24206882

  5. Sirolimus-eluting coronary stents in octogenarians: a 1-year analysis of the worldwide e-SELECT Registry.

    PubMed

    Hong, Young Joon; Jeong, Myung Ho; Abizaid, Alexander; Banning, Adrian; Bartorelli, Antonio; Dzavik, Vladimir; Ellis, Stephen G; Gao, Runlin; Holmes, David R; Legrand, Victor; Neumann, Franz-Josef; Spaulding, Christian; Worthley, Stephen; Urban, Philip

    2011-09-01

    The aim of this study was to identify the worldwide practice of Cypher Select (Cordis Corporation, Bridgewater, New Jersey) or Cypher Select Plus sirolimus-eluting stent (SES) in patients 80 years of age (octogenarian) and to identify clinical outcomes in this patient population. The use of drug-eluting stents in elderly patients may have different features compared with younger patients. Between 2006 and 2008, 15,147 patients from 320 hospitals in 56 countries were enrolled in a registry. Initial implantation and follow-up outcome information obtained at 1-year follow-up in 675 octogenarian patients were compared with those in 14,472 nonoctogenarian patients. Octogenarians had significantly more comorbidities and had higher Charlson comorbidity index scores (1.5 ± 1.6 vs. 1.0 ± 1.3, p < 0.001). Rates of cardiac death (3.3% vs. 0.9%, p < 0.001), myocardial infarction (2.3% vs. 1.9%, p = 0.021), and definite or probable stent thrombosis (2.3% vs. 0.9%, p = 0.0002), and major bleeding (2.0% vs. 0.9%, p = 0.015) were significantly higher in octogenarians at 1 year; however, there was no significant difference in the rate of target lesion revascularization between the 2 groups (3.2% vs. 2.2%, p = 0.12). In octogenarians, a high Charlson comorbidity index was an independent predictor of death and stent thrombosis up to 360 days from the index procedure (hazard ratio: 1.3, 95% confidence interval: 1.1 to 1.5, p < 0.001, and hazard ratio: 1.5, 95% confidence interval: 1.3 to 1.8, p < 0.001, respectively). Stenting with SES may be an effective therapeutic option in elderly patients, with acceptable rates of complications and a very low rate of repeat revascularization as demonstrated by this e-SELECT (A Multi-Center Post-Market Surveillance Registry) subgroup analysis. Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  6. Efficacy and safety of low-dose clopidogrel after 12-month dual antiplatelet therapy for patients having drug-eluting stent implantation.

    PubMed

    Zhuang, Xiao-Dong; Long, Ming; Li, Cui-Ling; Hu, Cheng-Heng; Du, Zhi-Ming; Liao, Xin-Xue

    2014-05-01

    To prevent stent thrombosis (ST) after implantation of drug-eluting stents (DESs) in patients with coronary heart disease, 12-month dual antiplatelet therapy (DAPT) is recommended. However, the optimal long-term antiplatelet regimen is not clear for the patients who have completed the 12-month DAPT. We reviewed the data of 755 consecutive patients who had undergone percutaneous coronary intervention (PCI) three years ago and completed 12-month DAPT. They were divided into three groups according to the antiplatelet medication they had used for two years after 12-month DAPT [low-dose clopidogrel (Talcom(®), 25mg/d), clopidogrel (Plavix(®), 75mg/d) and aspirin (100 mg/d)]. The efficacy (a composite incidence of cardiac death, myocardial infarction and target vessel revascularization) and safety (incidences of bleeding, gastrointestinal trouble and drug discontinuation) were compared among the three groups. The rates of multi-vessel lesions, prior MI, hemoglobin A1C (HbA1c) and low-density lipoprotein cholesterol were significantly higher in the clopidogrel (75 mg/day) group than in the other two groups (P>0.05 for both comparisons). There was no significant difference in the overall composite incidence of cardiac death, myocardial infarction and target vessel revascularization in the three groups at three years after PCI. The rates of bleeding (especially minor bleeding), gastrointestinal trouble, drug discontinuation and any blood transfusion were markedly lower in the low-dose clopidogrel (25 mg/d) group than in the other two treatment groups (P<0.05). The 25-mg maintenance dose of clopidogrel after 12-month DAPT may be more preferable to Chinese patients who have undergone DES implantation, because of its lower cost but no less efficacy and safety.

  7. Experimental evaluation of efficacy and healing response of everolimus-eluting stents in the familial hypercholesterolemic swine model: a comparative study of bioabsorbable versus durable polymer stent platforms.

    PubMed

    Tellez, Armando; Seifert, Paul S; Donskoy, Elina; Sushkova, Natalia; Pennington, Douglas E; Milewski, Krzysztof; Krueger, Christian G; Kaluza, Greg L; Eppihimer, Michael J; Huibregtse, Barbara A; Dawkins, Keith D; Granada, Juan F

    2014-05-01

    The utility of animal models for the prediction of drug-eluting stent (DES) efficacy in human clinical trials is still unclear. The familial hypercholesterolemic swine (FHS) model has been shown to induce a human-like neointimal response to bare metal stent (BMS) implantation. However, its utility to discriminate efficacy signals following DES implantation is unknown. In this study, we aimed to test the efficacy and healing response of several everolimus-eluting stent (EES) platforms in the coronary territory of the FHS. A total of 19 EES platforms (SYNERGY=6, SYNERGY½-dose=7, and PROMUS Element=6) and an identical BMS control (Element=6) were implanted into the coronary arteries of nine FHS. All implants were performed under intravascular ultrasound guidance using a 1.2 : 1 overstretch ratio. At 30 days, the vascular response to the implant was evaluated by quantitative coronary angiography, optical coherence tomography, and histology. At 28 days, all EES platforms showed a significant decrease in angiographic late lumen loss (between 27 and 37%) compared with the BMS control group. This finding was confirmed both by optical coherence tomography (mean neointimal thickness=28-42% reduction) and by histology (mean neointimal thickness=44-55% reduction). All EES platforms showed similar degrees of neointimal inhibition. The presence of moderate to severe para-strut inflammation was observed in 83% of the stent sections in the BMS group compared with 28.6% in the SYNERGY½-dose group and 0% in the SYNERGY and PROMUS groups (P=0.0002). There was a 68-95% reduction in MMP9 expression in the media in all EES platforms compared with the BMS controls. The presence of mild to moderate para-strut fibrin deposits ranged from 66.7 to 83.4% in all EES platforms compared with 16.7% in the EBMS group. The FHS coronary injury model showed the efficacy of several EES platforms compared with an identical BMS control. Everolimus eluted from different polymeric platforms showed lower

  8. [Implantation of the paclitaxel-eluting stent Apollo in patients with stable angina pectoris: long-term angiographic and clinical results].

    PubMed

    Batyraliev, T A; Fettser, D V; Samko, A N; Sidorenko, B A

    2010-01-01

    to assess the long-term angiographic and clinical results of percutaneous coronary interventions (PCI) with implantation of the drug-eluting stent (DES) Apollo in patients with stable angina pectoris. The study enrolled 48 patients with stable angina who had been implanted with 59 stents. A follow-up of the patients lasted 12 months. The intervention was successful in 100% patients. Following 12 months, 81.3% of the patients underwent angiography that demonstrated that the vascular diameter decreased by 0.32 +/- 0.45 mm and the rate of restenosis was reduced by only 5.3%. The frequency of evident cardiac complications over 12 months was as high as 11.6%. The DES Apollo provides a way of safely performing PCI, by achieving a high of angiographic success rate. The application of this stent yields long-term good angiographic and clinical results in patients with stable angina pectoris.

  9. Basic Concepts and Clinical Outcomes of Drug-Eluting Balloons for Treatment of Coronary Artery Disease: An Overview

    PubMed Central

    Ramakrishna, C. D.; Dave, Bhargav A.; Kothavade, Pankaj S.; Joshi, Kajal J.

    2017-01-01

    The technology of percutaneous coronary intervention for atherosclerotic coronary artery disease has evolved considerably since its inception. Though Drug-Eluting Stent (DES) reduces the rate of restenosis, long-term safety outcomes and persistent restenosis in complex lesion subset remain area of concern. Recently, Drug-Eluting Balloon (DEB) represents a novel treatment strategy for atherosclerotic coronary artery disease. DEB demonstrated its added value in preclinical studies. Inspired by these results, several clinical trials particularly in complex lesion subsets have been started to explore the value of this novel treatment strategy in a broader range of lesions. This review would summarise material compositions and different characteristics and clinical outcomes of currently available DEB. PMID:28764234

  10. RNA-Eluting Surfaces for the Modulation of Gene Expression as A Novel Stent Concept

    PubMed Central

    Koenig, Olivia; Zengerle, Diane; Perle, Nadja; Hossfeld, Susanne; Neumann, Bernd; Behring, Andreas; Avci-Adali, Meltem; Walker, Tobias; Schlensak, Christian; Wendel, Hans Peter; Nolte, Andrea

    2017-01-01

    Presently, a new era of drug-eluting stents is continuing to improve late adverse effects such as thrombosis after coronary stent implantation in atherosclerotic vessels. The application of gene expression–modulating stents releasing specific small interfering RNAs (siRNAs) or messenger RNAs (mRNAs) to the vascular wall might have the potential to improve the regeneration of the vessel wall and to inhibit adverse effects as a new promising therapeutic strategy. Different poly (lactic-co-glycolic acid) (PLGA) resomers for their ability as an siRNA delivery carrier against intercellular adhesion molecule (ICAM)-1 with a depot effect were tested. Biodegradability, hemocompatibility, and high cell viability were found in all PLGAs. We generated PLGA coatings with incorporated siRNA that were able to transfect EA.hy926 and human vascular endothelial cells. Transfected EA.hy926 showed significant siICAM-1 knockdown. Furthermore, co-transfection of siRNA and enhanced green fluorescent protein (eGFP) mRNA led to the expression of eGFP as well as to the siRNA transfection. Using our PLGA and siRNA multilayers, we reached high transfection efficiencies in EA.hy926 cells until day six and long-lasting transfection until day 20. Our results indicate that siRNA and mRNA nanoparticles incorporated in PLGA films have the potential for the modulation of gene expression after stent implantation to achieve accelerated regeneration of endothelial cells and to reduce the risk of restenosis. PMID:28208634

  11. Intra-stent tissue evaluation within bare metal and drug-eluting stents > 3 years since implantation in patients with mild to moderate neointimal proliferation using optical coherence tomography and virtual histology intravascular ultrasound.

    PubMed

    Kitabata, Hironori; Loh, Joshua P; Pendyala, Lakshmana K; Omar, Alfazir; Ota, Hideaki; Minha, Sa'ar; Magalhaes, Marco A; Torguson, Rebecca; Chen, Fang; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron

    2014-04-01

    We aimed to compare neointimal tissue characteristics between bare-metal stents (BMS) and drug-eluting stents (DES) at long-term follow-up using optical coherence tomography (OCT) and virtual histology intravascular ultrasound (VH-IVUS). Neoatherosclerosis in neointima has been reported in BMS and in DES. Thirty patients with 36 stented lesions [BMS (n=17) or DES (n=19)] >3years after implantation were prospectively enrolled. OCT and VH-IVUS were performed and analyzed independently. Stents with ≥70% diameter stenosis were excluded. The median duration from implantation was 126.0months in the BMS group and 60.0months in the DES group (p <0.001). Lipid-laden intima (58.8% vs. 42.1%, p=0.317), thrombus (17.6% vs. 5.3%, p=0.326), and calcification (35.3% vs. 26.3%, p=0.559) did not show significant differences between BMS and DES. When divided into 3 time periods, the cumulative incidence of lipid-laden neointima from >3years to <9years was similar between BMS and DES (42.9% vs. 42.1%, p=1.000). Furthermore, it continued to gradually increase over time in both groups. OCT-derived thin-cap fibroatheroma (TCFA) was observed in 17.6% of BMS- and 5.3% of DES-treated lesions (p=0.326). No stents had evidence of intimal disruption. The percentage volume of necrotic core (16.1% [9.7, 20.3] vs. 9.7% [7.0, 16.5], p=0.062) and dense calcium (9.5% [3.8, 13.6] vs. 2.7% [0.4, 4.9], p=0.080) in neointima tended to be greater in BMS-treated lesions. Intra-stent VH-TCFA (BMS vs. DES 45.5% vs. 18.2%, p=0.361) did not differ significantly. At long-term follow-up beyond 3 years after implantation, the intra-stent neointimal tissue characteristics appeared similar for both BMS and DES. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Testing prospectively the effectiveness and safety of paclitaxel-eluting stents in over 1000 very high-risk patients: design, baseline characteristics, procedural data and in-hospital outcomes of the multicenter Taxus in Real-life Usage Evaluation (TRUE) Study.

    PubMed

    Biondi-Zoccai, Giuseppe G L; Sangiorgi, Giuseppe M; Antoniucci, David; Grube, Eberhard; Di Mario, Carlo; Reimers, Bernard; Tamburino, Corrado; Agostoni, Pierfrancesco; Cosgrave, John; Colombo, Antonio

    2007-05-02

    Paclitaxel-eluting stents (PES) have been proved effective in randomized trials enrolling highly selected patients. Yet, given the uncertainty concerning results of PES implantation in very high-risk patients and lesions, we designed a prospective multicenter registry, the Taxus in Real-life Usage Evaluation (TRUE) Study. STUDY DESIGN, PATIENT CHARACTERISTICS AND IN-HOSPITAL OUTCOMES: Consecutive patients undergoing PES implantation were enrolled provided that the target lesion treated with PES was an unprotected left main (ULM), a true bifurcation, a chronic total occlusion (CTO), a long lesion (>28 mm), located in a small vessel (<2.75 mm), or the patient had diabetes mellitus. Clinical events will be adjudicated at 1, 7 and 12 months, with 4- to 8-month angiographic follow-up. The primary end-point will be the 7-month occurrence of major adverse cardiovascular events (MACE, i.e. the composite of cardiac death, non-fatal myocardial infarction [MI], coronary artery bypass grafting [CABG] and percutaneous target vessel revascularization [TVR]). To date, patient enrollment has been completed reaching the target of 1065 subjects. These included 322 (30.2%) diabetics, 115 (10.8%) subjects undergoing PES implantation for ULM, 229 (21.5%) in a bifurcation, 191 (17.9%) in a CTO, 430 (40.4%) in a small vessel, and 289 (27.1%) in a long lesion. An average of 1.5+/-0.6 vessels and 2.0+/-1.0 lesions were treated per patient, with 2.0+/-1.2 PES implanted per patient, and a 46+/-30 mm total PES length per patient. In-hospital MACE occurred in 39 (3.7%) patients, with 2 (0.2%) cardiac deaths, 32 (3.0%) MI, 5 (0.5%) TVR, no CABG, and 4 (0.4%) acute stent thromboses. Despite the availability of randomized trials, only carefully designed and prospective registries can provide timely and accurate assessment of the risk-benefit profile of PES in very high-risk patients. Indeed, the TRUE Study, including as much as 115 ULM and 229 bifurcation interventions, should give important

  13. Rationale and design of the East-West late lumen loss study: Comparison of late lumen loss between Eastern and Western drug-eluting stent study cohorts.

    PubMed

    Harrison, Robert W; Radhakrishnan, Vaishnavi; Lam, Peter S; Allocco, Dominic J; Brar, Sandeep; Fahy, Martin; Fisher, Rebecca; Ikeno, Fumiaki; Généreux, Philippe; Kimura, Takeshi; Liu, Minglei; Lye, Weng Kit; Mintz, Gary S; Nagai, Hirofumi; Suzuki, Yuka; White, Roseann; Allen, John C; Krucoff, Mitchell W

    2016-12-01

    The contemporary evaluation of novel drug-eluting stents (DES) includes mechanistic observations that characterize postdeployment stent behavior. Quantification of late lumen loss due to neointimal hyperplasia 8-13 months after stent implantation, via quantitative coronary angiography (QCA), constitutes such an observation and is required by most regulatory authorities. Late lumen loss, as determined by QCA, has been validated as a surrogate for clinical endpoints such as target vessel revascularization. The mechanistic response to DES has not been directly compared across predominantly Asian or Western populations, whereas understanding their comparability across geographic populations could enhance global DES evaluation. The East-West late lumen loss study is designed to demonstrate whether the residual differences in late lumen loss, as assessed by QCA, is different between Eastern and Western DES recipients from studies with protocol angiography at 8-13 months of follow-up. Data from independent core laboratories that have characterized angiographic late lumen loss in DES clinical trials with protocol follow-up angiography will be compiled and dichotomized into Eastern and Western populations. A prospectively developed propensity score model incorporating clinical and anatomic variables affecting late lumen loss will be used to adjust comparisons of QCA measurements. Documentation of whether there are clinically meaningful differences in mechanistic response to DES implantation across genetically unique geographies could facilitate both the quality and efficiency of global device evaluation requiring invasive follow-up for novel stent designs. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. The Impact of Post-Procedural Asymmetry, Expansion, and Eccentricity of Bioresorbable Everolimus-Eluting Scaffold and Metallic Everolimus-Eluting Stent on Clinical Outcomes in the ABSORB II Trial.

    PubMed

    Suwannasom, Pannipa; Sotomi, Yohei; Ishibashi, Yuki; Cavalcante, Rafael; Albuquerque, Felipe N; Macaya, Carlos; Ormiston, John A; Hill, Jonathan; Lang, Irene M; Egred, Mohaned; Fajadet, Jean; Lesiak, Maciej; Tijssen, Jan G; Wykrzykowska, Joanna J; de Winter, Robbert J; Chevalier, Bernard; Serruys, Patrick W; Onuma, Yoshinobu

    2016-06-27

    The study sought to investigate the relationship between post-procedural asymmetry, expansion, and eccentricity indices of metallic everolimus-eluting stent (EES) and bioresorbable vascular scaffold (BVS) and their respective impact on clinical events at 1-year follow-up. Mechanical properties of a fully BVS are inherently different from those of permanent metallic stent. The ABSORB II (A bioresorbable everolimus-eluting scaffold versus a metallic everolimus-eluting stent for ischaemic heart disease caused by de-novo native coronary artery lesions) trial compared the BVS and metallic EES in the treatment of a de novo coronary artery stenosis. Protocol-mandated intravascular ultrasound imaging was performed pre- and post-procedure in 470 patients (162 metallic EES and 308 BVS). Asymmetry index (AI) was calculated per lesion as: (1 - minimum scaffold/stent diameter/maximum scaffold/stent diameter). Expansion index and optimal scaffold/stent expansion followed the definition of the MUSIC (Multicenter Ultrasound Stenting in Coronaries) study. Eccentricity index (EI) was calculated as the ratio of minimum and maximum scaffold/stent diameter per cross section. The incidence of device-oriented composite endpoint (DoCE) was collected. Post-procedure, the metallic EES group was more symmetric and concentric than the BVS group. Only 8.0% of the BVS arm and 20.0% of the metallic EES arm achieved optimal scaffold/stent expansion (p < 0.001). At 1 year, there was no difference in the DoCE between both devices (BVS 5.2% vs. EES 3.1%; p = 0.29). Post-procedural devices asymmetry and eccentricity were related to higher event rates while there was no relevance to the expansion status. Subsequent multivariate analysis identified that post-procedural AI >0.30 is an independent predictor of DoCE (hazard ratio: 3.43; 95% confidence interval: 1.08 to 10.92; p = 0.037). BVS implantation is more frequently associated with post-procedural asymmetric and eccentric morphology compared

  15. Long term outcomes of new generation drug eluting stents versus coronary artery bypass grafting for multivessel and/or left main coronary artery disease. A Bayesian network meta-analysis of randomized controlled trials.

    PubMed

    Mina, George S; Watti, Hussam; Soliman, Demiana; Shewale, Anand; Atkins, Jessica; Reddy, Pratap; Dominic, Paari

    2018-01-05

    Most data guiding revascularization of multivessel disease (MVD) and/or left main disease (LMD) favor coronary artery bypass grafting (CABG) over percutaneous coronary intervention (PCI). However, those data are based on trials comparing CABG to bare metal stents (BMS) or old generation drug eluting stents (OG-DES). Hence, it is essential to outcomes of CABG to those of new generation drug eluting stents (NG-DES). We searched PUBMED and Cochrane database for trials evaluating revascularization of MVD and/or LMD with CABG and/or PCI. A Bayesian network meta-analysis was performed to calculate odds ratios (OR) and 95% credible intervals (CrI). Primary outcome was major adverse cardiovascular events (MACE) at 3-5 years. Secondary outcomes were mortality, cerebrovascular accidents (CVA), myocardial infarction (MI) and repeat revascularization. We included 10 trials with a total of 9287 patients. CABG was associated with lower MACE when compared to BMS or OG-DES. However, MACE was not significantly different between CABG and NG-DES (OR 0.79, CrI 0.45-1.40). Moreover, there were no significant differences between CABG and NG-DES in mortality (OR 0.78, CrI 0.45-1.37), CVA (OR 0.93 CrI 0.35-2.2) or MI (OR 0.6, CrI 0.17-2.0). On the other hand, CABG was associated with lower repeat revascularization (OR 0.55, CrI 0.36-0.84). Our study suggests that NG-DES is an acceptable alternative to CABG in patients with MVD and/or LMD. However, repeat revascularization remains to be lower with CABG than with PCI. Copyright © 2018. Published by Elsevier Inc.

  16. New predictors of in-stent restenosis in patients with diabetes mellitus undergoing percutaneous coronary intervention with drug-eluting stent.

    PubMed

    Wang, Jian-Long; Qin, Zheng; Wang, Zhi-Jian; Shi, Dong-Mei; Liu, Yu-Yang; Zhao, Ying-Xin; Yang, Li-Xia; Cheng, Wan-Jun; Zhou, Yu-Jie

    2018-02-01

    Percutaneous coronary intervention (PCI) had become the major therapeutic procedure for coronary artery disease (CAD), but the high rate of in-stent restenosis (ISR) still remained an unsolved clinical problem in clinical practice. Increasing evidences suggested that diabetes mellitus (DM) was a major risk factor for ISR, but the risk predictors of ISR in CAD patients with DM had not been well characterized. The aim of this study was to investigate the clinical and angiographic characteristic predictors significantly associated with the occurrence of ISR in diabetic patients following coronary stenting with drug-eluting stent (DES). A total of 920 patients with diabetes who diagnosed CAD and underwent coronary DES implantation at Beijing Anzhen Hospital in China were consecutively enrolled from January 2012 to December 2012. Of these, 440 patients underwent the second angiography within ≥ 6 months due to the progression of treated target lesions. Finally, 368 of these patients who met the inclusion and exclusion criteria were followed up by angiography after baseline PCI. According to whether ISR was detected at follow-up angiography, patients were divided into the ISR group ( n = 74) and the non-ISR group ( n = 294). The independent predictors of ISR in patients with DM were explored by multivariate Cox's proportional hazards regression models. A total of 368 patients (260 women and 108 men) with a mean ages of 58.71 ± 10.25 years were finally enrolled in this study. Of these, ISR occurred in 74/368 diabetic patients (20.11%) by follow-up angiography. Univariate analysis showed that most baseline characteristics of the ISR and non-ISR group were similar. Patients in the ISR group had significantly higher serum very low density lipoprotein cholesterol (VLDL-C), triglyceride (TG) and uric acid (UA) levels, more numbers of target vessel lesions, higher prevalence of multi-vessel disease, higher SYNTAX score, higher rate of previous but lower rate of drinking

  17. Comparison between Exclusive and Selective Drug-Eluting Stent Strategies in Treating Patients with Multivessel Coronary Artery Disease

    PubMed Central

    Tung, Ying-Chang; Hsiao, Ping-Gune; Hsu, Lung-An; Kuo, Chi-Tai; Chang, Chi-Jen

    2014-01-01

    Background The expanded usage of drug-eluting stents (DES) in treating patients with multivessel coronary artery disease (CAD) may sometimes be limited in real-world practice due to cost concerns. We compared the clinical outcomes of exclusive and selective DES use in treating patients with multivessel CAD. Methods From November 2004 to December 2011, 110 patients with multivessel CAD who received four or more stents were enrolled into this study, and divided into two groups according to the DES strategy employed: exclusive DES (n = 52), or selective DES (n = 58). In the selective DES group, DES was reserved for complex lesions only, such that the incidence and predictors of clinical events were assessed. Results At a mean follow-up of 41.4 ± 26.5 months, there were no significant differences between the two strategies in terms of baseline characteristics, all-cause mortality (exclusive vs. selective: 1.9% vs. 6.9%, p = 0.21), cardiac death (1.9% vs. 1.7%, p = 0.94) and nonfatal myocardial infarction (3.8% vs. 5.2%, p = 0.74). Despite the presence of more ostial lesions in the exclusive DES group, there was a trend such that major adverse cardiac events (MACE) and target lesion revascularization (TLR) rates were higher in the selective DES group (MACE: 17.3% vs. 31%, p = 0.16; TLR: 11.5% vs. 24.1%, p = 0.08). The higher MACE rate in the selective DES group was mainly driven by a higher target vessel revascularization (TVR) rate (15.4% vs. 29.3%, p = 0.08). In the exclusive DES group, SYNTAX score was an independent predictor of MACE [Haxard ratio (HR): 1.09, 95% confidence internal (CI): 1.02-1.16, p = 0.01] and TVR (HR 1.08, 95% CI 1.01-1.15, p = 0.04). Conclusions Compared to the exclusive DES strategy, the selective DES strategy with reservation of DES for complex lesions is associated with numerically higher, but not statistically significant, rates of MACE and all-cause mortality in this small group of patients with multivessel CAD receiving four or more

  18. Comparison of different antithrombotic regimens for patients with atrial fibrillation undergoing drug-eluting stent implantation.

    PubMed

    Gao, Fei; Zhou, Yu Jie; Wang, Zhi Jian; Shen, Hua; Liu, Xiao Li; Nie, Bin; Yan, Zhen Xian; Yang, Shi Wei; Jia, De An; Yu, Miao

    2010-04-01

    The optimal antithrombotic strategy for patients with atrial fibrillation (AF) undergoing drug-eluting stent (DES) implantation is unknown. The 622 consecutive AF patients undergoing DES implantation were prospectively enrolled. Among them, 142 patients (TT group) continued triple antithrombotic therapy comprising aspirin, clopidogrel and warfarin after discharge; 355 patients (DT group) had dual antiplatelet therapy; 125 patients (WS group) were discharged with warfarin and a single antiplatelet agent. Target INR was set as 1.8-2.5 and was regularly monitored after discharge. The TT group had a significant reduction in stroke and major adverse cardiac and cerebral events (MACCE) (8.8% vs 20.1% vs 14.9%, P=0.010) as compared with either the DT or WS group. In the Cox regression analysis, administration with warfarin (hazard ratio (HR) 0.49; 95% confidence interval (CI) 0.31-0.77; P=0.002) and baseline CHADS(2) score >or=2 (HR 2.09; 95%CI 1.27-3.45; P=0.004) were independent predictors of MACCE. Importantly, the incidence of major bleeding was comparable among 3 groups (2.9% vs 1.8% vs 2.5%, P=0.725), although the overall bleeding rate was increased in the TT group. Kaplan-Meier analysis indicated that the TT group was associated with the best net clinical outcome. The cardiovascular benefits of triple antithrombotic therapy were confirmed by reducing the MACCE rate, and its major bleeding risk might be acceptable if the INR is closely monitored.

  19. Attitudes towards drug-eluting stent use and the distribution of motivation type among interventional cardiologists.

    PubMed

    Qian, Feng; Phelps, Charles E; Ling, Frederick S; Hannan, Edward L; Veazie, Peter J

    2012-06-01

    The safety of drug-eluting stent (DES) use was called into question in 2006. However, the attitudes towards DES use after DES safety concerns were expressed and the distribution of chronic motivation type among interventional cardiologists are unknown. This study aims to examine the current attitudes towards DES use among interventional cardiologists and to investigate the distribution of chronic motivation type among these doctors. A questionnaire survey of interventional cardiologists was conducted in New York State from October 2008 to April 2009. The questionnaire included face valid items to measure the attitudes towards DES use, valid Regulatory Focus Questionnaire to measure the chronic motivation type, and items collecting demographic information. A total of 119 valid responses were received (response rate: 47%). There were no statistically significant differences regarding the demographic factors between the respondents and the non-respondents. The vast majority of interventional cardiologists (92%) agreed that 'DES is a revolutionary technology' and that 'DES use will increase in the future' (70%). The chronic motivation type of the respondents was predominantly sensitive to positive outcomes (89%). Interventional cardiologists had a very positive attitude regarding DES technology and predicted future growth of DES use. The vast majority of interventional cardiologists were found to be concerned about achieving positive outcomes and wanted to prevent errors of omission. To the best of our knowledge, this is the first study to report the distribution of chronic motivation type among doctors. © 2011 Blackwell Publishing Ltd.

  20. Rationale of a novel study design for the BIOFLOW V study, a prospective, randomized multicenter study to assess the safety and efficacy of the Orsiro sirolimus-eluting coronary stent system using a Bayesian approach.

    PubMed

    Doros, Gheorghe; Massaro, Joseph M; Kandzari, David E; Waksman, Ron; Koolen, Jacques J; Cutlip, Donald E; Mauri, Laura

    2017-11-01

    Traditional study design submitted to the Food and Drug Administration to test newer drug-eluting stents (DES) for marketing approval is the prospective randomized controlled trial. However, several DES have extensive clinical data from trials conducted outside the United States that have led to utilization of a novel design using the Bayesian approach. This design was proposed for testing DES with bioresorbable polymer compared with DES most commonly in use today that use durable polymers for drug elution. This prospective, multicenter, randomized, controlled trial is designed to assess the safety and efficacy of the Orsiro bioresorbable polymer sirolimus-eluting stent (BP SES). Up to 1,334 subjects with up to 3 de novo or restenotic coronary artery lesions who qualify for percutaneous coronary intervention with stenting will be randomized 2:1 to the BP SES versus the Xience durable polymer everolimus-eluting stent (DP EES). Data from this trial will be combined with data from 2 similarly designed trials that also randomize subjects to BP SES and DP EES (BIOFLOW II, N=452 and BIOFLOW IV, N=579) by using a Bayesian approach. The primary end point is target lesion failure at 12 months post index procedure, defined as cardiac death, target vessel myocardial infarction, or clinically driven target lesion revascularization, and the primary analysis is a test of noninferiority of the BP SES versus DP EES on the primary end point according to a noninferiority delta of 3.85%. Secondary end points include stent thrombosis and the individual components of target lesion failure. Subjects will be followed for 5 years after randomization. The BIOFLOW V trial offers an opportunity to assess clinical outcomes in patients treated with coronary revascularization using the Orsiro BP SES relative to a commonly used DP EES. The use of a Bayesian analysis combines a large randomized cohort of patients 2 two smaller contributing randomized trials to augment the efficiency of the

  1. Biodegradable, elastomeric coatings with controlled anti-proliferative agent release for magnesium-based cardiovascular stents.

    PubMed

    Gu, Xinzhu; Mao, Zhongwei; Ye, Sang-Ho; Koo, Youngmi; Yun, Yeoheung; Tiasha, Tarannum R; Shanov, Vesselin; Wagner, William R

    2016-08-01

    Vascular stent design continues to evolve to further improve the efficacy and minimize the risks associated with these devices. Drug-eluting coatings have been widely adopted and, more recently, biodegradable stents have been the focus of extensive evaluation. In this report, biodegradable elastomeric polyurethanes were synthesized and applied as drug-eluting coatings for a relatively new class of degradable vascular stents based on Mg. The dynamic degradation behavior, hemocompatibility and drug release were investigated for poly(carbonate urethane) urea (PCUU) and poly(ester urethane) urea (PEUU) coated magnesium alloy (AZ31) stents. Poly(lactic-co-glycolic acid) (PLGA) coated and bare stents were employed as control groups. The PCUU coating effectively slowed the Mg alloy corrosion in dynamic degradation testing compared to PEUU-coated, PLGA-coated and bare Mg alloy stents. This was confirmed by electron microscopy, energy-dispersive x-ray spectroscopy and magnesium ion release experiments. PCUU-coating of AZ31 was also associated with significantly reduced platelet adhesion in acute blood contact testing. Rat vascular smooth muscle cell (rSMC) proliferation was successfully inhibited when paclitaxel was released from pre-loaded PCUU coatings. The corrosion retardation, low thrombogenicity, drug loading capacity, and high elasticity make PCUU an attractive option for drug eluting coating on biodegradable metallic cardiovascular stents. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Longer- Versus Shorter-Duration Dual-Antiplatelet Therapy After Drug-Eluting Stent Placement: A Systematic Review and Meta-analysis.

    PubMed

    Spencer, Frederick A; Prasad, Manya; Vandvik, Per O; Chetan, Devin; Zhou, Qi; Guyatt, Gordon

    2015-07-21

    The appropriate duration of dual-antiplatelet therapy (DAPT) after drug-eluting stent (DES) placement remains controversial. To summarize data on clinical outcomes with longer- versus shorter-duration DAPT after DES placement in adults with coronary artery disease. Ovid MEDLINE and EMBASE, 1996 to 27 March 2015, and manual screening of references. Randomized, controlled trials comparing longer- versus shorter-duration DAPT after DES placement. Two reviewers screened potentially eligible articles; extracted data on populations, interventions, and outcomes; assessed risk of bias; and used the Grading of Recommendations Assessment, Development and Evaluation guidelines to rate overall confidence in effect estimates. Among 1010 articles identified, 9 trials including 29,531 patients were eligible; data were complete for 28,808 patients. Moderate-quality evidence showed that longer-duration DAPT decreased risk for myocardial infarction (risk ratio [RR], 0.73 [95% CI, 0.58 to 0.92]) and increased mortality (RR, 1.19 [CI, 1.04 to 1.36]). High-quality evidence showed that DAPT increased risk for major bleeding (RR, 1.63 [CI, 1.34 to 1.99]). Confidence in estimates were decreased owing to imprecision for most outcomes (particularly myocardial infarction), risk of bias from limited blinding in 7 of 9 studies, indirectness due to variability in use of first- and second-generation stents, and off-protocol use of DAPT in some studies. Extended DAPT is associated with approximately 8 fewer myocardial infarctions per 1000 treated patients per year but 6 more major bleeding events than shorter-duration DAPT. Because absolute effects are very small and closely balanced, decisions regarding the duration of DAPT therapy must take into account patients' values and preference. None.

  3. Stent Polymers: Do They Make a Difference?

    PubMed

    Rizas, Konstantinos D; Mehilli, Julinda

    2016-06-01

    The necessity of polymers on drug-eluting stent (DES) platforms is dictated by the need of an adequate amount and optimal release kinetic of the antiproliferative drugs for achieving ideal DES performance. However, the chronic vessel wall inflammation related to permanent polymer persistence after the drug has been eluted might trigger late restenosis and stent thrombosis. Biodegradable polymers have the potential to avoid these adverse events. A variety of biodegradable polymer DES platforms have been clinically tested, showing equal outcomes with the standard-bearer permanent polymer DES within the first year of implantation. At longer-term follow-up, promising lower rates of stent thrombosis have been observed with the early generation biodegradable polymer DES platforms compared to first-generation DES. Whether this safety benefit still persists with newer biodegradable polymer DES generations against second-generation permanent polymer DES needs to be explored. © 2016 American Heart Association, Inc.

  4. An Update to Hepatobiliary Stents

    PubMed Central

    Moy, Brian T.; Birk, John W.

    2015-01-01

    Endoscopic stent placement is a common primary management therapy for benign and malignant biliary strictures. However, continuous use of stents is limited by occlusion and migration. Stent technology has evolved significantly over the past two decades to reduce these problems. The purpose of this article is to review current guidelines in managing malignant and benign biliary obstructions, current endoscopic techniques for stent placement, and emerging stent technology. What began as a simple plastic stent technology has evolved significantly to include uncovered, partially covered, and fully covered self-expanding metal stents (SEMS) as well as magnetic, bioabsorbable, drug-eluting, and antireflux stents.1 PMID:26357636

  5. Drug eluting balloons for the treatment of coronary artery disease: What can we expect?

    PubMed Central

    Joost, Alexander; Kurowski, Volkhard; Radke, Peter W

    2010-01-01

    Drug-eluting balloons (DEBs) represent an enhancement of the therapeutic repertoire for the interventional cardiologist. The therapeutic concept of DEBs is promising, notably on the basis of initial studies in patients with diffuse in-stent restenosis (ISR). At present, however, a number of questions regarding long-term efficacy and safety remain, specifically in indications other than diffuse ISR. The results of the evaluation of different substances, balloon systems and clinical indications will determine the long-term success of DEBs. PMID:21160601

  6. Diabetic and nondiabetic patients with left main and/or 3-vessel coronary artery disease: comparison of outcomes with cardiac surgery and paclitaxel-eluting stents.

    PubMed

    Banning, Adrian P; Westaby, Stephen; Morice, Marie-Claude; Kappetein, A Pieter; Mohr, Friedrich W; Berti, Sergio; Glauber, Mattia; Kellett, Mirle A; Kramer, Robert S; Leadley, Katrin; Dawkins, Keith D; Serruys, Patrick W

    2010-03-16

    This study was designed to compare contemporary surgical revascularization (coronary artery bypass graft surgery [CABG]) versus TAXUS Express (Boston Scientific, Natick, Massachusetts) paclitaxel-eluting stents (PES) in diabetic and nondiabetic patients with left main and/or 3-vessel disease. Although the prevalence of diabetes mellitus is increasing, the optimal coronary revascularization strategy in diabetic patients with complex multivessel disease remains controversial. The SYNTAX (SYNergy between percutaneous coronary intervention with TAXus and cardiac surgery) study randomly assigned 1,800 patients (452 with medically treated diabetes) to receive PES or CABG. The overall 1-year major adverse cardiac and cerebrovascular event rate was higher among diabetic patients treated with PES compared with CABG, but the revascularization method did not impact the death/stroke/myocardial infarction rate for nondiabetic patients (6.8% CABG vs. 6.8% PES, p = 0.97) or for diabetic patients (10.3% CABG vs. 10.1% PES, p = 0.96). The presence of diabetes was associated with significantly increased mortality after either revascularization treatment. The incidence of stroke was higher among nondiabetic patients after CABG (2.2% vs. PES 0.5%, p = 0.006). Compared with CABG, mortality was higher after PES use for diabetic patients with highly complex lesions (4.1% vs. 13.5%, p = 0.04). Revascularization with PES resulted in higher repeat revascularization for nondiabetic patients (5.7% vs. 11.1%, p < 0.001) and diabetic patients (6.4% vs. 20.3%, p < 0.001). Subgroup analyses suggest that the 1-year major adverse cardiac and cerebrovascular event rate is higher among diabetic patients with left main and/or 3-vessel disease treated with PES compared with CABG, driven by an increase in repeat revascularization. However, the composite safety end point (death/stroke/myocardial infarction) is comparable between the 2 treatment options for diabetic and nondiabetic patients. Although

  7. Treatment strategies for coronary in-stent restenosis: systematic review and hierarchical Bayesian network meta-analysis of 24 randomised trials and 4880 patients

    PubMed Central

    Giacoppo, Daniele; Gargiulo, Giuseppe; Aruta, Patrizia; Capranzano, Piera; Tamburino, Corrado

    2015-01-01

    Study question What is the most safe and effective interventional treatment for coronary in-stent restenosis? Methods In a hierarchical Bayesian network meta-analysis, PubMed, Embase, Scopus, Cochrane Library, Web of Science, ScienceDirect, and major scientific websites were screened up to 10 August 2015. Randomised controlled trials of patients with any type of coronary in-stent restenosis (either of bare metal stents or drug eluting stents; and either first or recurrent instances) were included. Trials including multiple treatments at the same time in the same group or comparing variants of the same intervention were excluded. Primary endpoints were target lesion revascularisation and late lumen loss, both at six to 12 months. The main analysis was complemented by network subanalyses, standard pairwise comparisons, and subgroup and sensitivity analyses. Study answer and limitations Twenty four trials (4880 patients), including seven interventional treatments, were identified. Compared with plain balloons, bare metal stents, brachytherapy, rotational atherectomy, and cutting balloons, drug coated balloons and drug eluting stents were associated with a reduced risk of target lesion revascularisation and major adverse cardiac events, and with reduced late lumen loss. Treatment ranking indicated that drug eluting stents had the highest probability (61.4%) of being the most effective for target lesion vascularisation; drug coated balloons were similarly indicated as the most effective treatment for late lumen loss (probability 70.3%). The comparative efficacy of drug coated balloons and drug eluting stents was similar for target lesion revascularisation (summary odds ratio 1.10, 95% credible interval 0.59 to 2.01) and late lumen loss reduction (mean difference in minimum lumen diameter 0.04 mm, 95% credible interval −0.20 to 0.10). Risks of death, myocardial infarction, and stent thrombosis were comparable across all treatments, but these analyses were limited by a

  8. Recent developments in drug eluting devices with tailored interfacial properties.

    PubMed

    Sanchez-Rexach, Eva; Meaurio, Emilio; Sarasua, Jose-Ramon

    2017-11-01

    Drug eluting devices have greatly evolved during past years to become fundamental products of great marketing importance in the biomedical field. There is currently a large diversity of highly specialized devices for specific applications, making the development of these devices an exciting field of research. The replacement of the former bare metal devices by devices loaded with drugs allowed the sustained and controlled release of drugs, to achieve the desired local therapeutic concentration of drug. The newer devices have been "engineered" with surfaces containing micro- and nanoscale features in a well-controlled manner, that have shown to significantly affect cellular and subcellular function of various biological systems. For example, the topography can be structured to form an antifouling surface mimicking the defense mechanisms found in nature, like the skin of the shark. In the case of bone implants, well-controlled nanostructured interfaces can promote osteoblast differentiation and matrix production, and enhance short-term and long-term osteointegration. In any case, the goal of current research is to design implants that induce controlled, guided, and rapid healing. This article reviews recent trends in the development of drug eluting devices, as well as recent developments on the micro/nanotechnology scales, and their future challenges. For this purpose medical devices have been divided according to the different systems of the body they are focused to: orthopedic devices, breathing stents, gastrointestinal and urinary systems, devices for cardiovascular diseases, neuronal implants, and wound dressings. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Outcomes of ≤6-month versus 12-month dual antiplatelet therapy after drug-eluting stent implantation

    PubMed Central

    Villablanca, Pedro A.; Massera, Daniele; Mathew, Verghese; Bangalore, Sripal; Christia, Panagiota; Perez, Irving; Wan, Ningxin; Schulz-Schüpke, Stefanie; Briceno, David F.; Bortnick, Anna E.; Garcia, Mario J.; Lucariello, Richard; Menegus, Mark; Pyo, Robert; Wiley, Jose; Ramakrishna, Harish

    2016-01-01

    Abstract Background: The benefit of ≤6-month compared with 12-month dual antiplatelet therapy (DAPT) after percutaneous coronary intervention (PCI) with drug-eluting stent (DES) placement remains controversial. We performed a meta-analysis and meta-regression of ≤6-month versus 12-month DAPT in patients undergoing PCI with DES placement. Methods: We conducted electronic database searches of randomized controlled trials (RCTs) comparing DAPT durations after DES placement. For studies with longer follow-up, outcomes at 12 months were identified. Odds ratios and 95% confidence intervals were computed with the Mantel–Haenszel method. Fixed-effect models were used; if heterogeneity (I2) > 40 was identified, effects were obtained with random models. Results: Nine RCTs were included with total n = 19,224 patients. No significant differences were observed between ≤6-month compared with 12-month DAPT in all-cause mortality (OR 0.87; 95% confidence interval (CI): 0.69–1.11), cardiovascular (CV) mortality (OR 0.89; 95% CI: 0.66–1.21), non-CV mortality (OR 0.85; 95% 0.58–1.24), myocardial infarction (OR 1.10; 95% CI: 0.89–1.37), stroke (OR 0.97; 95% CI: 0.67–1.42), stent thrombosis (ST) (OR 1.37; 95% CI: 0.89–2.10), and target vessel revascularization (OR 0.95; 95% CI: 0.77–1.18). No significant difference in major bleeding (OR 0.72; 95% CI: 0.49–1.05) was observed, though the all-bleeding event rate was significantly lower in the ≤6-month DAPT group (OR 0.76; 95% CI: 0.59–0.96). In the meta-regression analysis, a significant association between bleeding events and non-CV mortality with 12-month DAPT was found, as well as between ST and mortality in addition to MI with ≤6-month DAPT. Conclusion: DAPT for ≤6 months is associated with similar mortality and ischemic outcomes but less bleeding events compared with 12-month DAPT after PCI with DES. PMID:28033306

  10. Comparison of Long-Term Clinical Outcomes of Lesions Exhibiting Focal and Segmental Peri-Stent Contrast Staining.

    PubMed

    Tokuda, Takahiro; Yamawaki, Masahiro; Takahara, Mitsuyohi; Mori, Shinsuke; Makino, Kenji; Honda, Yosuke; Takafuji, Hiroya; Takama, Takuro; Tsutsumi, Masakazu; Sakamoto, Yasunari; Takimura, Hideyuki; Kobayashi, Norihiro; Araki, Motoharu; Hirano, Keisuke; Ito, Yoshiaki

    2016-03-18

    Peri-stent contrast staining (PSS) after metallic drug-eluting stent deployment is associated with target lesion revascularization and very late stent thrombosis. However, the type of PSS that influences the clinical outcomes is unknown. Therefore, we aimed to reveal which PSS type was influencing clinical outcomes. This study included 5580 de novo lesions of 4405 patients who were implanted with a first- or second-generation drug-eluting stent and who were evaluated using follow-up angiography within 12 months after stent implantation. We compared the clinical outcomes of patients divided into focal PSS and segmental PSS groups for 6 years after stent implantation. Total PSS was observed in 97 lesions (2.2%), of which 42 and 55 lesions were focal and segmental PSS, respectively. Baseline characteristics were similar between groups, except for intraoperative chronic total occlusion (segmental PSS=47.3% versus focal PSS=11.9%, P=0.0001). The incidence of segmental PSS tended to be higher in patients with a first-generation drug-eluting stent (83.6% versus 16.4%, P=0.05). The cumulative incidence of stent thrombosis in the 6 years of segmental PSS group was significantly higher than that of the focal PSS group (13.9% versus 0%, P=0.04). The cumulative incidence of overall target lesion revascularization for restenosis, excluding target lesion revascularization procedures for stent thrombosis, was significantly higher in the segmental PSS group (38.0% versus 0%, P=0.01). The incidence of segmental PSS tended to be higher in patients with a first-generation drug-eluting stent and appeared to be significantly associated with target lesion revascularization and stent thrombosis. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  11. Análisis Costo Efectividad del Stent Farmacológico V/S Stent no Farmacológico en Cardiopatía Isquémica en Chile.

    PubMed

    De la Puente, Catherine; Vallejos, Carlos; Velásquez, Mónica; Soto, David; Orellana, Juan

    2012-12-01

    To evaluate and compare the costs and effectiveness of two alternative stent, drug eluting stent (SF) and bare metal stent (SNF). Cost-utility analysis based on a Markov model using data from a cohort study of Hospital Las Higueras of Talcahuano, Chile. The effectiveness measure was the rate of restenosis and the time of restenosis. The effectiveness outcomes are expressed in quality-adjusted life years (QALY) gained. Costs are expressed in national currency 2011. The evaluation perspective was from the public heath budget. We model a cohort from age 63 to 80 years, life expectancy in Chile. Apply discount rate of 0, 3% and 6% for results and costs. Sensitivity analysis is performed according to the ranges of variability in costs, the utility values of the variables and transition between states. No differences in restenosis rates between the two stents, although there were differences in the time of restenosis. The incremental cost effectiveness ratio (ICER) no discount rate was CH$ 235.749 per QALY gained when using drug-eluting stent, the value below the equivalent of 1 Gross Domestic Product (PIB) per capita for 2011 in Chile. The drug-eluting stent (SF) is cost effective compared to bare metal stent (SNF). The ICER is not affected by the sensitivity analysis (variability of cost, utility ranges used, probability of restenosis). Copyright © 2012 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  12. First-in-man study of simvastatin-eluting stent in de novo coronary lesions: the SIMVASTENT study.

    PubMed

    Zago, Alexandre C; Matte, Bruno S; Reginato, Luciana; Iturry-Yamamoto, Germán; Krepsky, Ana; Bergoli, Luiz Carlos C; Balvedi, Julise; Raudales, José C; Saadi, Eduardo K; Zago, Alcides J

    2012-01-01

    Statins have anti-inflammatory and antiproliferative properties irrespective of their cholesterol-lowering effects. The aim of the present study was to evaluate a simvastatin-eluting stent (SimvES) in the treatment of de novo coronary lesions. Forty-two patients with de novo coronary artery lesions were assigned to SimvES, bare-metal stent (BMS) or everolimus-eluting stent (EES) implantation followed by intravascular ultrasound (IVUS) for neointimal quantitative analysis. Six months later, quantitative coronary angiography (QCA) and IVUS were repeated. QCA showed no binary restenosis, a mean in-stent late loss of 1.05 ± 0.25 mm (BMS, 1.12 ± 0.48 mm; EES, 0.20 ± 0.16 mm) and a diameter stenosis of 33.5 ± 7.1% (BMS, 35.5 ± 15.30%; EES, 7.2 ± 3.12%). Control IVUS showed a mean in-stent obstruction of 18.3 ± 9.4% (BMS, 32.8 ± 19.1%; EES, 9.8 ± 2.4%) and a neointimal volume index of 1.58 ± 0.75 mm(3)/mm (BMS, 2.93 ± 1.76 mm(3)/mm; EES, 0.80 ± 0.16 mm(3)/mm). Thrombus, late incomplete apposition and major adverse cardiac events were not observed. In this sample of patients with de novo coronary lesions, the use of a SimvES was not related to major adverse cardiac events, but it was associated with a higher level of neointimal proliferation than expected.

  13. Newest-generation drug-eluting and bare-metal stents combined with prasugrel-based antiplatelet therapy in large coronary arteries: the BAsel Stent Kosten Effektivitäts Trial PROspective Validation Examination part II (BASKET-PROVE II) trial design.

    PubMed

    Jeger, Raban; Pfisterer, Matthias; Alber, Hannes; Eberli, Franz; Galatius, Søren; Naber, Christoph; Pedrazzini, Giovanni; Rickli, Hans; Jensen, Jan Skov; Vuilliomenet, André; Gilgen, Nicole; Kaiser, Christoph

    2012-02-01

    In the BAsel Stent Kosten Effektivitäts Trial PROspective Validation Examination (BASKET-PROVE), drug-eluting stents (DESs) had similar 2-year rates of death and myocardial infarction but lower rates of target vessel revascularization and major adverse cardiac events compared with bare-metal stents (BMSs). However, comparative clinical effects of newest-generation DES with biodegradable polymers vs second-generation DES or newest-generation BMS with biocompatible coatings, all combined with a prasugrel-based antiplatelet therapy, on 2-year outcomes are not known. In BASKET-PROVE II, 2,400 patients with de novo lesions in native vessels ≥3 mm in diameter are randomized 1:1:1 to receive a conventional DES, a DES with a biodegradable polymer, or a BMS with biocompatible coating. In addition to aspirin, stable patients with BMS will receive prasugrel for 1 month, whereas all others will receive prasugrel for 12 months. The primary end point will be combined cardiac death, nonfatal myocardial infarction, and target vessel revascularization up to 2 years. Secondary end points include stent thrombosis and major bleeding. The primary aim is to test (1) the noninferiority of a biodegradable-polymer DES to a conventional DES and (2) the superiority of both DESs to BMS. A secondary aim is to compare the outcomes with those of BASKET-PROVE regarding the effects of prasugrel-based vs clopidogrel-based antiplatelet therapy. By the end of 2010, 878 patients (37% of those planned) were enrolled. This study will test the comparative long-term safety and efficacy of newest-generation stents on the background of contemporary antiplatelet therapy in a large all-comer population undergoing large native coronary artery stenting. Copyright © 2012 Mosby, Inc. All rights reserved.

  14. 9-month results of polymer-free sirolimus eluting stents in young patients compared to a septuagenarian and octogenarian all-comer population.

    PubMed

    Kherad, Behrouz; Waliszewski, Matthias; Leschke, Matthias; Kader, Muhammad Ali; Bang, Liew Houng; Ruiz-Poveda, Fernando Lozano; Pieske, Burkert; Krackhardt, Florian

    2018-06-01

    To evaluate the 9-month safety and efficacy of polymer-free sirolimus eluting drug eluting stents in septuagenarians and octogenarians. An all-comer, worldwide single armed trial (ClinicalTrials.gov Identifier NCT02629575) was conducted to demonstrate the safety and efficacy of an ultra-thin strut, polymer-free sirolimus eluting stent (PF-SES). The primary endpoint was the 9-month target revascularization rate (TLR). Secondary endpoints included the rates of major adverse cardiac events (MACE), stent thrombosis (ST) and bleeding (BARC) in septuagenarians (≥70 years, <80 years), and in octogenarians (≥80 years) to be compared to the younger patient group (<70 years). A total of 1607 patients were treated with PF-SES in the sub-70-year-old age group, 694 in septuagenarians, and 371 in the octogenarian patient group. At 9 months, the MACE rates were 7.2% in octogenarians, 5.3% in septuagenarians, and 3.0% in the younger patient group (P = 0.001). These were mostly driven by all-cause mortality (4.4% vs 1.9% vs 0.6%, P < 0.001) while the TLR rates were only numerically lower in the younger age group (P = 0.080). BARC 1-5 bleeding events were more frequent in the older age group (1.9% vs 2.7% vs 4.6%, P = 0.012) whereas the rates for ST were not different (0.7% vs 0.6% vs 0.6%, P = 0.970). In octogenarians treated with PF-SES, the rates for MACE, overall mortality, and bleeding are higher as compared to the younger age groups. However, the rates for TLR and ST were not significantly different across the investigated age groups. PF-SES are safe and effective in octogenarians. © 2017, Wiley Periodicals, Inc.

  15. Intravascular Drug Release Kinetics Dictate Arterial Drug Deposition, Retention, and Distribution

    PubMed Central

    Balakrishnan, Brinda; Dooley, John F.; Kopia, Gregory; Edelman, Elazer R.

    2007-01-01

    Millions of patients worldwide have received drug-eluting stents to reduce their risk for in-stent restenosis. The efficacy and toxicity of these local therapeutics depend upon arterial drug deposition, distribution, and retention. To examine how administered dose and drug release kinetics control arterial drug uptake, a model was created using principles of computational fluid dynamics and transient drug diffusion-convection. The modeling predictions for drug elution were validated using empiric data from stented porcine coronary arteries. Inefficient, minimal arterial drug deposition was predicted when a bolus of drug was released and depleted within seconds. Month-long stent-based drug release efficiently delivered nearly continuous drug levels, but the slow rate of drug presentation limited arterial drug uptake. Uptake was only maximized when the rates of drug release and absorption matched, which occurred for hour-long drug release. Of the two possibly means for increasing the amount of drug on the stent, modulation of drug concentration potently impacts the magnitude of arterial drug deposition, while changes in coating drug mass affect duration of release. We demonstrate the importance of drug release kinetics and administered drug dose in governing arterial drug uptake and suggest novel drug delivery strategies for controlling spatio-temporal arterial drug distribution. PMID:17868948

  16. Current manufacturing processes of drug-eluting sutures.

    PubMed

    Champeau, Mathilde; Thomassin, Jean-Michel; Tassaing, Thierry; Jérôme, Christine

    2017-11-01

    Drug-eluting sutures represent the next generation of surgical sutures since they fulfill their mechanical functions but also deliver the drug in their vicinity after implantation. These implants are produced by a variety of manufacturing processes. Drug-eluting sutures represent the next generation of surgical sutures since they fulfill their mechanical functions but also deliver the drug in their vicinity after implantation. These implants are produced by a variety of manufacturing processes. Two general approaches can be followed: (i) the ones that add the API into the material during the manufacturing process of the suture and (ii) the ones that load the API to an already manufactured suture. Areas covered: This review provides an overview of the current manufacturing processes for drug-eluting suture production and discusses their benefits and drawbacks depending on the type of drugs. The mechanical properties and the drug delivery profile of drug-eluting sutures are highlighted since these implants must fulfill both criteria. Expert opinion: For limited drug contents, melt extrusion and electrospinning are the emerging processes since the drug is added during the suture manufacture process. Advantageously, the drug release profile can be tuned by controlling the processing parameters specific to each process and the composition of the drug-containing polymer. If high drug content is targeted, the coating or grafting of a drug layer on a pre-manufactured suture allows for preservation of the tensile strength requirements of the suture.

  17. Stent thrombosis and bleeding complications after implantation of sirolimus-eluting coronary stents in an unselected worldwide population: a report from the e-SELECT (Multi-Center Post-Market Surveillance) registry.

    PubMed

    Urban, Philip; Abizaid, Alexandre; Banning, Adrian; Bartorelli, Antonio L; Baux, Ana Cebrian; Džavík, Vladimír; Ellis, Stephen; Gao, Runlin; Holmes, David; Jeong, Myung Ho; Legrand, Victor; Neumann, Franz-Josef; Nyakern, Maria; Spaulding, Christian; Worthley, Stephen

    2011-03-29

    The aim of this study was to ascertain the 1-year incidence of stent thrombosis (ST) and major bleeding (MB) in a large, unselected population treated with sirolimus-eluting stents (SES). Stent thrombosis and MB are major potential complications of drug-eluting stent implantation. Their relative incidence and predisposing factors among large populations treated worldwide are unclear. The SES were implanted in 15,147 patients who were entered in a multinational registry. We analyzed the incidence of: 1) definite and probable ST as defined by the Academic Research Consortium; and 2) MB, with the STEEPLE (Safety and efficacy of Enoxaparin in PCI) definition, together with their relation to dual antiplatelet therapy (DAPT) and to 1-year clinical outcomes. The mean age of the sample was 62 ± 11 years, 30.4% were diabetic, 10% had a Charlson comorbidity index ≥3, and 44% presented with acute coronary syndrome or myocardial infarction. At 1 year, the reported compliance with DAPT as recommended by the European Society of Cardiology guidelines was 86.3%. Adverse event rates were: ST 1.0%, MB 1.0%, mortality 1.7%, myocardial infarction 1.9%, and target lesion revascularization 2.3%. Multivariate analysis identified 9 correlates of ST and 4 correlates of MB. Advanced age and a high Charlson index were associated with an increased risk of both ST and MB. After ST, the 7-day and 1-year all-cause mortality was 30% and 35%, respectively, versus 1.5% and 10% after MB. Only 2 of 13,749 patients (0.015%) experienced both MB and ST during the entire 1-year follow-up period. In this worldwide population treated with ≥1 SES, the reported compliance with DAPT was good, and the incidence of ST and MB was low. Stent thrombosis and MB very rarely occurred in the same patient. (The e-SELECT Registry: a Multicenter Post-Market Surveillance; NCT00438919). Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  18. Inhibition of plaque neovascularization and intimal hyperplasia by specific targeting vascular endothelial growth factor with bevacizumab-eluting stent: an experimental study.

    PubMed

    Stefanadis, Christodoulos; Toutouzas, Konstantinos; Stefanadi, Elli; Lazaris, Andreas; Patsouris, Efstratios; Kipshidze, Nicholas

    2007-12-01

    Neovascularization is associated with destabilization of atheromatic plaques. Increased expression of vascular endothelial growth factor (VEGF) is important in the process of neovascularization. We assessed the effect of bevacizumab, a monoclonal antibody specific for VEGF, on neovascularization. We used 12 New Zealand rabbits under atherogenic diet for 3 weeks. We immersed a phosphorycholine coated stent into a solution of 4 ml bevacizumab according to previous studies. Twelve eluting stents and 12 non-eluting stents were implanted in the middle segment of the rabbit's iliac arteries. Follow-up angiography was performed at 4 weeks and tissues were obtained for histological analysis. The procedure of stent loading with bevacizumab and stent implantation was successful. There was no difference in angiographic measurements before, after implantation and at follow-up between the two groups. mean neointimal thickness (0.09+/-0.02 versus 0.12+/-0.02 mm, p<0.01), and mean neointimal area (1.08+/-0.09 versus 1.20+/-0.12 mm(2), p<0.01) were less in the bevacizumab treated segments. bevacizumab-treated arterial segments demonstrated significantly decreased microvessel density compared with the control group (1.69+/-0.06 CI: 1.65-1.73 versus 15.68+/-0.56 CI: 15.32-16.04 vessels per mm(2), p<0.001) and vegf expression was decreased in the media and adventitia of bevacizumab group. Endothelialization, inflammation and injury scores were similar between the two groups. These results suggest that bevacizumab-eluting stent implantation in rabbit iliac arteries is safe, and inhibits neovascularization without affecting the endothelialization.

  19. [Effects of control-releasing arsenic trioxide-eluting stent on intimal smooth muscle cells and type III collagen in canine coronary artery post-stent model].

    PubMed

    Zhao, Jun-Li; Sun, Bao-Gui; Wen, Qin-Zhu

    2010-06-01

    To study the safety and efficacy of control-releasing arsenic trioxide (As2O3)-eluting stent on intimal smooth muscle cells (SMC) and type III collagen (CIII) in canine coronary artery post-stent model. Twenty-four experimental canines were equally divided into 4 groups, the three tested groups were deployed by stents with different dosage of As2O3 (1.6 microg/mm2, 2.4 microg/mm2 and 3.2 microg/mm2 in low, median and high dose groups, respectively) and coated with polybutyl methacrylate/nano silica and poly-lactide-coglycolide in mild oversizing (stent/vessel ratio of 1.3:1) in left anterior descending (LAD) or circumflex coronary arteries (LCX), while the control group only by simple coated stent without As2O3. The effect was assessed 4 weeks after stent implantation in terms of vascular histomorphology, and changes of SMC and C III expressions were detected using immunohistochemical analysis. Subintimal hemorrhage, medial/adventitial necrosis, thrombosis and inflammatory cell infiltration were not found and integral endothelium could be seen under screening electron microscopy in all groups. Positive expression of SMC and CIII in the tested groups, especial in the high dose As2O3 group, was more weaker than that in control group. Histo-morphological analysis showed that the neo-genetic intimal area and vascular stenosis were lower, but the mean luminal diameter was larger in the three tested groups than that in the control group (P < 0.01). Comparisons of various indices between tested groups treated by different doses of As2O3 showed that the difference between high/median dose vs. low dose was significant (P < 0.01), but that between high dose vs. median dose was insignificant (P > 0.05). Control-releasing As2O3-eluting stent shows a reliable and safe effect in preventing and treating post-stent restenosis by its dose-dependent inhibition on expressions of SMC and CIII to suppress the neo-genesis of intimal hyperplasia.

  20. Drug-eluting stents and glycoprotein IIb/IIIa inhibitors in vessels at low anatomic risk: a retrospective analysis of previously published data from the Basel Stent Kosten Effektivitäts Trial.

    PubMed

    Jeger, Raban V; Brunner-La Rocca, Hans Peter; Hunziker, Patrick R; Tsakiris, Dimitrios A; Kaiser, Christoph A; Pfisterer, Matthias E

    2009-12-01

    Drug-eluting stents (DESs) are associated with late stent thromboses, but the exact mechanism of action is unknown. The goal of this article was to assess the clinical interaction of glycoprotein IIb/IIIa inhibitors (GPIs) with different stent and vessel types in unselected patients undergoing percutaneous coronary intervention (PCI). This was a predefined retrospective analysis of the randomized controlled Basel Stent Kosten Effektivitats Trial (BASKET), which compared DES with bare-metal stents (BMSs) in patients undergoing PCI. Patients were compared for major adverse clinical events in relation to GPI use (abciximab and tirofiban) after 18 months. In a subgroup analysis prespecified in the study protocol, specific regard was given to angiographic groups at different risk levels for late events (high-risk vessels [ie, small vessels with a diameter <3.0 mm and saphenous vein grafts], and low-risk vessels [ie, large native vessels > or =3.0 mm]). Baseline differences between patients with or without GPI use were identified and incorporated into a multivariable Cox proportional hazards regression analysis if different at a <0.05 level. A total of 826 patients (650 males, 176 females) were enrolled in BASKET; 301 (36%) received GPI therapy. Of these 301 patients, 255 (85%) received abciximab and 46 (15%) received tirofiban. After 18 months, the rate of cardiac death and nonfatal myocardial infarction was higher in patients with GPI use than in those without GPI use (35/301 [12%] vs 32/525 [6%]; P = 0.005). In patients undergoing PCI in anatomically low-risk vessels and receiving GPI therapy, there was a higher rate of cardiac death and nonfatal myocardial infarction at 18 months with a DES versus a BMS (22/151 [15%] vs 3/66 [5%]; P = 0.033). In patients undergoing PCI in anatomically low-risk vessels and without GPI therapy, there was no significant difference for cardiac death and nonfatal myocardial infarction (DES vs BMS, 11/207 [5%] vs 6/134 [4%]). In the

  1. The Impact of Blood Rheology on Drug Transport in Stented Arteries: Steady Simulations

    PubMed Central

    Vijayaratnam, Pujith R. S.; O’Brien, Caroline C.; Reizes, John A.; Barber, Tracie J.; Edelman, Elazer R.

    2015-01-01

    Background and Methods It is important to ensure that blood flow is modelled accurately in numerical studies of arteries featuring drug-eluting stents due to the significant proportion of drug transport from the stent into the arterial wall which is flow-mediated. Modelling blood is complicated, however, by variations in blood rheological behaviour between individuals, blood’s complex near-wall behaviour, and the large number of rheological models which have been proposed. In this study, a series of steady-state computational fluid dynamics analyses were performed in which the traditional Newtonian model was compared against a range of non-Newtonian models. The impact of these rheological models was elucidated through comparisons of haemodynamic flow details and drug transport behaviour at various blood flow rates. Results Recirculation lengths were found to reduce by as much as 24% with the inclusion of a non-Newtonian rheological model. Another model possessing the viscosity and density of blood plasma was also implemented to account for near-wall red blood cell losses and yielded recirculation length increases of up to 59%. However, the deviation from the average drug concentration in the tissue obtained with the Newtonian model was observed to be less than 5% in all cases except one. Despite the small sensitivity to the effects of viscosity variations, the spatial distribution of drug matter in the tissue was found to be significantly affected by rheological model selection. Conclusions/Significance These results may be used to guide blood rheological model selection in future numerical studies. The clinical significance of these results is that they convey that the magnitude of drug uptake in stent-based drug delivery is relatively insensitive to individual variations in blood rheology. Furthermore, the finding that flow separation regions formed downstream of the stent struts diminish drug uptake may be of interest to device designers. PMID:26066041

  2. A comparison of clinical and angiographic outcomes after Excel bioabsorbable polymer versus Firebird durable polymer rapamycin-eluting stent for the treatment of coronary artery disease in a "real world" setting: six-month follow-up results.

    PubMed

    Liu, Hai-bo; Xu, Bo; Qiao, Shu-bin; Yang, Yue-jin; Ma, Wei-hua; Qin, Xue-wen; Yao, Min; Wu, Yong-jian; Yuan, Jin-qing; Chen, Jue; You, Shi-jie; Dai, Jun; Xia, Ran; Li, Jian-jun; Chen, Ji-lin; Gao, Run-lin

    2007-04-05

    Several clinical trials have shown that rapamycin-eluting stents significantly reduce the risk of restenosis after percutaneous coronary intervention (PCI). The Firebird stent and the Excel stent (coated with bioabsorbable polymer) are two different types of rapamycin-eluting stents made in China, both have been recently approved for clinical use in China by State Food and Drug Administration. However, it is unclear whether there are differences in safety and efficacy between the two types of stents in daily practice. In the month of June 2006, a total of 190 consecutive patients were treated exclusively with Firebird stents (n = 93, Firebird group) or Excel stents (n = 97, Excel group) in our center and were included in this study. The frequency of major adverse cardiac events (MACE, a composite of death, myocardial infarction or target lesion revascularization), binary restenosis, and late lumen loss and stent thrombosis during a six-month follow-up period were compared between the two groups. Patient and lesion characteristics were comparable between the groups. Major adverse cardiac event rates were low in hospital and at 6 months (2.1% in the Excel group and 0% in the Firebird group, P > 0.05). The 6-month angiographic in-stent restenosis rate was 0% in both groups, with an associated late loss of (0.15 +/- 0.21) mm versus (0.14 +/- 0.20) mm (P = 0.858) and the in-segment restenosis rate was also 0% for the Excel group and the Firebird group. There was no definite stent thrombosis identified in either group during the six-month follow-up period and only one patient in the Excel group had probable stent thrombosis in hospital. Results from this mid-term, single-center study showed that both of the Firebird and the Excel rapamycin eluting stent had similar effects on reducing the incidence of MACE and the risk of restenosis (both in-stent and in-segment binary restenosis) after PCI in daily practice.

  3. Feelings of being disabled as a prognostic factor for mortality in the drug-eluting stent era.

    PubMed

    Simsek, Cihan; Pedersen, Susanne S; van Gestel, Yvette R B M; Erdman, Ruud A M; Daemen, Joost; Serruys, Patrick W; van Domburg, Ron T

    2009-07-01

    It remains unclear whether feelings of being disabled are a relevant psychological factor that determines outcome after percutaneous coronary intervention (PCI). Therefore, we evaluated "feelings of being disabled" as an independent risk factor for mortality 4 years post-PCI. As part of the Taxus-Stent Evaluated At Rotterdam Cardiology Hospital (T-SEARCH) Registry, 658 consecutive patients (age 63 years, 75% male) completed the subscale "feelings of being disabled" of the Heart Patients Psychological Questionnaire (HPPQ), within the first month after PCI. At 4-year follow-up, 8% of the patients (n=55) had died, 2% (n=16) underwent a myocardial infarction (MI), 13% (n=90) had a target-vessel revascularization (TVR), and 21% (n=137) had one or more major adverse cardiac events (MACE). One-third of the patients (32%) had high scores on "feelings of being disabled" at baseline. After adjusting for baseline characteristics, including symptoms of anxiety and depression, patients with a high score on "feelings of being disabled" had an increased risk for all cause mortality (HR=2.9, 95% CI=1.5-5.6), the composite end point mortality/MI (HR=2.4, 95% CI=1.3-4.4), and the occurrence of MACE (HR=1.7, 95% CI=1.1-2.7). Feelings of being disabled were an independent predictor of all-cause mortality, mortality/MI, and MACE 4 years post-PCI. These patients should be identified in clinical practice, as they warrant additional treatment, e.g., of a psychosocial nature, in addition to the standard medical treatment.

  4. Significantly lower incidence of early definite stent thrombosis of drug-eluting stents after unrestricted use in Japan using ticlopidine compared to western countries using clopidogrel: a retrospective comparison with western mega-studies.

    PubMed

    Ishikawa, Tetsuya; Nakano, Yosuke; Endoh, Akira; Kubota, Takeyuki; Suzuki, Teruhiko; Nakata, Koutarou; Miyamoto, Takashi; Murakami, Michiaki; Sakamoto, Hiroshi; Imai, Kamon; Mochizuki, Seibu; Yoshimura, Michihiro; Mutoh, Makoto

    2009-10-01

    The incidence of definite stent thrombosis (ST) after use of drug-eluting stents (DES), as defined by the Academic Research Consortium, is known to be lower in Japan than in western countries. However, a statistical difference in the incidence of early definite ST (EDST) associated with the unrestricted use of DES has not yet been documented. Therefore, the incidence of EDST in our Japanese institute after unrestricted use of DES was retrospectively compared with those reported in western mega-studies. During the 40 months from August 2004 to November 2007 (before approval of clopidogrel in Japan), DES were implanted in 3605 lesions in 1885 patients in our institute; lesion- and patient-associated percentages of DES use were 95.2% and 94.7%, respectively. Mean stent length per lesion was 33.2 mm, emergent procedures and ST-elevation myocardial infarctions made up 33.7% and 16.4% of the procedures, respectively, intravascular ultrasonography was used 96.0% of the time, a distal protection device for acute coronary syndrome was used 68.7% of the time, and the mean maximum inflation pressure was 19.5 atm. EDST was observed in five lesions (0.139%) in four patients (0.212%). The incidence of patient-associated EDST at our center was significantly lower than in four western mega-studies (0.736%, 66 of 8970 patients; 0.634%, 149 of 23,500; 0.595%, 52 of 8402; 0.997%, 20 of 2006) (p<0.05, <0.01, <0.05, <0.01, respectively, using a chi(2)-test). Due to differences in procedural approaches in Japan, the incidence of EDST after unrestricted use of DES was significantly lower than in western countries.

  5. A practical method to rapidly dissolve metallic stents.

    PubMed

    Bradshaw, Scott H; Kennedy, Lloyd; Dexter, David F; Veinot, John P

    2009-01-01

    Metallic stents are commonly used in many clinical applications including peripheral vascular disease intervention, biliary obstruction, endovascular repair of aneurysms, and percutaneous coronary interventions. In the examination of vascular stent placement, it is important to determine if the stent is open or has become obstructed. This is increasingly important in the era of drug-eluting stent usage in coronary arteries. We describe a practical, rapid and cost-effective method to dissolve most metallic stents leaving the vascular and luminal tissues intact. This practical method may replace the laborious and expensive plastic embedding methods currently utilized.

  6. Stenting of the Upper Gastrointestinal Tract: Current Status

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Katsanos, Konstantinos; Sabharwal, Tarun, E-mail: tarun.sabharwal@gstt.nhs.uk; Adam, Andreas

    2010-08-15

    Minimally invasive image-guided insertion of self-expanding metal stents in the upper gastrointestinal tract is the current treatment of choice for palliation of malignant esophageal or gastroduodenal outlet obstructions. A concise review is presented of contemporary stenting practice of the upper gastrointestinal tract, and the procedures in terms of appropriate patient evaluation, indications, and contraindications for treatment are analyzed, along with available stent designs, procedural steps, clinical outcomes, inadvertent complications, and future technology. Latest developments include biodegradable polymeric stents for benign disease and radioactive or drug-eluting stents for malignant obstructions.

  7. Endovascular techniques in limb salvage: cutting, cryo, brachy, and drug-eluting balloons.

    PubMed

    Davies, Mark G; Anaya-Ayala, Javier E

    2013-04-01

    The complex pathophysiology response to injury of the lower-extremity arteries has prompted the development of several unique balloon technologies to overcome initial technical failures and short-term intimal hyperplasia. Cryoplasty alters the cellular and mechanical properties of the vessel wall during angioplasty. Cutting balloons incise the wall, preventing elastic recoil and allowing expansion of the lumen at a lower pressure, thus limiting barotrauma. Drug-eluting balloons actively transfer inhibitory compounds to the wall during the initial therapy, while brachytherapy balloons allow for localized delivery of radiation to inhibit the proliferative response seen after angioplasty. These platforms provide unique means to enhance immediate and short-term results and also reduce stent usage in the lower extremity.

  8. ABSORB II randomized controlled trial: a clinical evaluation to compare the safety, efficacy, and performance of the Absorb everolimus-eluting bioresorbable vascular scaffold system against the XIENCE everolimus-eluting coronary stent system in the treatment of subjects with ischemic heart disease caused by de novo native coronary artery lesions: rationale and study design.

    PubMed

    Diletti, Roberto; Serruys, Patrick W; Farooq, Vasim; Sudhir, Krishnankutty; Dorange, Cecile; Miquel-Hebert, Karine; Veldhof, Susan; Rapoza, Richard; Onuma, Yoshinobu; Garcia-Garcia, Hector M; Chevalier, Bernard

    2012-11-01

    Currently, no data are available on the direct comparison between the Absorb everolimus-eluting bioresorbable vascular scaffold (Absorb BVS) and conventional metallic drug-eluting stents. The ABSORB II study is a randomized, active-controlled, single-blinded, multicenter clinical trial aiming to compare the second-generation Absorb BVS with the XIENCE everolimus-eluting metallic stent. Approximately 501 subjects will be enrolled on a 2:1 randomization basis (Absorb BVS/XIENCE stent) in approximately 40 investigational sites across Europe and New Zealand. Treated lesions will be up to 2 de novo native coronary artery lesions, each located in different major epicardial vessels, all with an angiographic maximal luminal diameter between 2.25 and 3.8 mm as estimated by online quantitative coronary angiography (QCA) and a lesion length of ≤48 mm. Clinical follow-up is planned at 30 and 180 days and at 1, 2, and 3 years. All subjects will undergo coronary angiography, intravascular ultrasound (IVUS) and IVUS-virtual histology at baseline (pre-device and post-device implantation) and at 2-year angiographic follow-up. The primary end point is superiority of the Absorb BVS vs XIENCE stent in terms of vasomotor reactivity of the treated segment at 2 years, defined as the QCA quantified change in the mean lumen diameter prenitrate and postnitrate administration. The coprimary end point is the noninferiority (reflex to superiority) of the QCA-derived minimum lumen diameter at 2 years postnitrate minus minimum lumen diameter postprocedure postnitrate by QCA. In addition, all subjects allocated to the Absorb BVS group will undergo multislice computed tomography imaging at 3 years. The ABSORB II randomized controlled trial (ClinicalTrials.gov NCT01425281) is designed to compare the safety, efficacy, and performance of Absorb BVS against the XIENCE everolimus-eluting stent in the treatment of de novo native coronary artery lesions. Copyright © 2012 Mosby, Inc. All rights

  9. Advanced stent coating for drug delivery and in vivo biocompatibility

    NASA Astrophysics Data System (ADS)

    Liu, Yi; Wang, Wuchen; Acharya, Gayathri; Shim, Yoon-Bo; Choe, Eun Sang; Lee, Chi H.

    2013-10-01

    As an effort to alleviate stent-induced cardiovascular injury including restenosis and thrombosis, advanced drug-eluting stent (ADES) with a bilayer construct composed of a top-coat made of collagen and a base-coat incorporated with N-nitrosomelatonin (NOMela)-loaded PLGA nanoparticles has been developed. NOMela is a hydrophobic prodrug of nitric oxide (NO) that is an endogenous anti-platelet compound. ADES was coated with PLGA nanoparticles via either electrophoretic deposition (EPD) technique or dip-coating technique, and their coating characteristics and efficacies were compared. The drug-loading efficacy and in vitro drug-release profiles from ADES were expressed with various variables including the additives to the collagen layer, the number of layers of the collagen top-coat, the hydrophobicity/hydrophilicity of the loaded drug, the coating technique of nanoparticles, and the concentration of coating emulsions in the EPD method. The morphological status of cross-section and surface of ADES was evaluated by laser scanning confocal microscope and scanning electronic microscope. The real-time release profiles of NO were assessed using the NO-microbiosensor. The anti-platelet activity of ADES was evaluated on the rabbit whole blood using an aggregometer. The intima formation and protein expression in aorta were examined using an in vivo rat model. Both collagen and PLGA used in ADES are biodegradable polymers that fully degrade and consequently produce less inflammation responses. NO released from ADES significantly reduced platelet aggregation in the rabbit blood as compared with those exposed to the control stents. ADES coated with a double layer consisted of collagen and PLGA and containing NOMela was less antigenic at the implanted sites and alleviating intima formation and thrombosis. An external exposure of aorta to NO elicits distinct and specific effects on mitogen-activated protein kinase (MAPK) and Ca2+/calmodulin-dependent protein kinase II (Ca

  10. Incidence of adverse cardiac events 5 years after polymer-free sirolimus eluting stent implantation: Results from the prospective Bad Berka Yukon Choice™ registry.

    PubMed

    Ohlow, Marc-Alexander; von Korn, Hubertus; Gunkel, Oliver; Farah, Ahmed; Fuhrmann, Joerg T; Lauer, Bernward

    2014-12-01

    Drug-eluting stents (DES) constitute a major achievement in preventing re-stenosis, concerns remain regarding the increased inflammatory responses associated with the polymers used. This analysis focuses on outcomes in patients receiving the polymer-free sirolimus-eluting stent system YUKON-Choice (Yukon-DES, Translumina, Germany). From 01/2006-09/2008 all patients receiving Yukon-DES (≥2.5 mm diameter) were prospectively enrolled in our registry. The primary endpoint was long-term major adverse cardiac events (MACE). 701 patients were included in our registry. Mean age was 65.7 ± 10 years (73% male gender, 35.5% diabetes, and 32.2% acute coronary syndrome). 76% of the lesions were of Type B2/C. Lesion length was 24.6 ± 5.2 mm and mean stent diameter was 2.8 ± 0.4 mm. A total of 511 pts (72%) underwent 6-months angiographic follow-up, target vessel revascularization was noted in 23.5%. At 5 years clinical outcomes were: cardiac death 5.8%; myocardial infarction 3.4%; and TVR 24.6%. The incidence of MACE differed significantly between "on-label" and "off-label" indications (14.8% vs. 40.8% MACE; P < 0.001). Incidence of definitive/probable stent thrombosis (ST) was 1.14% (8/701); very late (>1 year) ST occurred in 0.29%. Our data suggests that the implantation of the sirolimus-coated polymer-free YUKON-DES is safe and feasible with a very low incidence of ST in this real world patient cohort with high percentage of diabetes and small vessels. © 2013 Wiley Periodicals, Inc.

  11. Prasugrel vs. clopidogrel in contemporary Western European patients with acute coronary syndromes receiving drug-eluting stents: Comparative cost-effectiveness analysis from the BASKET-PROVE cohorts.

    PubMed

    Wein, Bastian; Coslovsky, Michael; Jabbari, Reza; Galatius, Søren; Pfisterer, Matthias; Kaiser, Christoph

    2017-12-01

    Clinical and cost-effectiveness of prasugrel vs. clopidogrel in acute coronary syndrome (ACS) was only evaluated using TRITON-TIMI 38 event rates. A comparative analysis of both drugs in contemporary European ACS patients is lacking. To address this issue, cardiac and bleeding events of 2 "sister" multicenter stent trials, BASKET-PROVE (BP) I with clopidogrel and BPII with prasugrel (for 12months each) were used in a hybrid analysis. Medication costs were 2015 sales prices, event costs modelled for Denmark (DNK), Germany (GER) and Switzerland (SUI) and quality adjusted life years (QALY) by EQ-5D-3L questionnaire. In BPI and II, 1012 and 985 ACS-patients received drug eluting stents, respectively, followed-up for 2years. Compared to clopidogrel, prasugrel-treated patients had no more major cardiac events (5.2% vs. 6.4%, p=0.422) nor cardiac deaths (1.6% vs. 1.0%, p=0.255), but more major bleedings (4.0% vs. 1.7%, p<0.001) and altogether no difference in QALYs (-0.027 (95%CI: -0.064/0.011)). Prasugrel caused higher total expenditures per patient: 1116.3 (DNK), 1063.5 (GER) and 880.8 (SUI) EURO, respectively. Accordingly, incremental cost-effectiveness was negative for prasugrel vs. clopidogrel with ratios of -45,907 (DNK), -39,909 (GER) and -33,435 (SUI) EURO/QALY gained, making clopidogrel an economically dominant strategy, even after accounting for the non-randomized comparison. Findings of this contemporary European ACS-cohort showed markedly lower cardiac event rates than TRITON-TIMI 38 and no significant difference in 2-year QALYs between prasugrel and clopidogrel-treated patients. At current drug prices, clopidogrel use resulted in an economically dominant treatment strategy in Western European patients. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Gravisensing, apoptosis, and drug recovery in Taxus cell suspensions

    NASA Technical Reports Server (NTRS)

    Durzan, D. J.

    1999-01-01

    Haploid and diploid cell suspensions of Taxus spp. were examined for their adaptive plasticity in response to simulated microgravity, unit gravity, and hypergravity. Cell suspensions produced the taxane, paclitaxel, (TAXOL (R)), which is useful for the treatment of various cancers. Amyloplasts contributed to taxane ring biosynthesis and to drug release at the cell wall. Drug-producing cells reacted as gravisensing osmotic tensiometers. In stressed cells, amyloplasts docked and fused in clusters to sites on the plasmalemma before taxane discharge into the culture medium. In simulated microgravity and compared to all other treatments, taxane production was reduced nearly 100-fold. The percent paclitaxel of total taxanes remained 3-to 6-fold greater, and biomass doubled. When p53-independent programmed cell death was induced, taxanes were released into the culture medium as free molecules (soluble and insoluble) or bound to membranes, nuclear fragments, xylan residues, and other particulate materials. Unit gravity and especially hypergravity promoted xylogenesis and significant drug overproduction. A model relating families of >touch = (TCH), taxane early response (TER), nuclear cycling, and apoptosis-regulating genes to gravisensing, cell wall modifications, and to taxane recovery accounted for most but not all of the observations.

  13. The Integrity bare-metal stent made by continuous sinusoid technology.

    PubMed

    Turco, Mark A

    2011-05-01

    The Integrity Coronary Stent System (Medtronic Vascular, CA, USA) is a low-profile, open-cell, cobalt-chromium-alloy advanced bare-metal iteration of the well-known Driver/Micro-Driver Coronary Stent System (Medtronic Vascular). The Integrity stent is made with a process called continuous sinusoid technology. This process allows stent construction via wrapping a single thin strand of wire around a mandrel in a sinusoid configuration, with laser fusion of adjacent crowns. The wire-forming process and fusion pattern provide the stent with a continuous preferential bending plane, intended to allow easier access to, and smoother tracking within, distal and tortuous vessels while radial strength is maintained. Continuous sinusoid technology represents innovation in the design of stent platforms and will provide a future stent platform for newer technology, including drug-eluting stent platforms, drug-filled stents and core wire stents.

  14. Does stent strut design impact clinical outcomes: comparative safety and efficacy of Endeavor Resolute versus Resolute Integrity zotarolimus-eluting stents.

    PubMed

    Di Santo, Pietro; Simard, Trevor; Ramirez, F Daniel; Pourdjabbar, Ali; Harnett, David T; Singh, Kuljit; Moreland, Robert; Chong, Aun-Yeong; Dick, Alexander; Labinaz, Marino; Froeschl, Michael; Froeschl, Michael; Le May, Michael R; So, Derek Y; Hibbert, Benjamin

    2015-10-07

    Percutaneous coronary intervention is the most commonly performed method of revascularizing obstructive coronary artery disease. The impact of stent strut design on clinical outcomes remains unclear. The Endeavour Resolute (ER-ZES) and the Resolute Integrity (RI-ZES) zotarolimus-eluting stents utilize identical polymers and anti-proliferative agents, differing only in their respective strut design. This study assessed the comparative safety and efficacy of these two stents in unrestricted contemporary real-world practice. A total of 542 patients were identified, corresponding to 340 ER-ZES and 480 RI-ZES. The primary endpoint was major adverse cardiac events (MACE) defined by a composite of death, nonfatal myocardial infarction and stroke. Secondary endpoints included post-procedural length of stay, in-stent restenosis, target lesion revascularization, target vessel revascularization, coronary artery bypass grafting and stent thrombosis. MACE occurred in 3.2% of the ER-ZES cohort and 5.0% of the RI-ZES cohort (p= 0.43). Adjusted analysis utilizing propensity score-adjusted odds ratio for MACE, was 1.37 (95% CI 0.46-4.07, p=0.57). The mortality rate (0.9% ER-ZES vs. 1.9% RI-ZES, p=0.59), non-fatal MI (2.3% ER-ZES vs. 3.1% RI-ZES, p=0.75) and stroke (0.0% ER-ZES vs. 0.3% RI-ZES, p=0.85) were not different. Additionally, there was no difference in any of secondary outcomes. The clinical performance and safety of both ER-ZES and RI-ZES were not statistically different, despite differences in stent strut design.

  15. Drug-eluting versus bare-metal stents in unprotected left main coronary artery stenosis a meta-analysis.

    PubMed

    Pandya, Sanjay B; Kim, Young-Hak; Meyers, Sheridan N; Davidson, Charles J; Flaherty, James D; Park, Duk-Woo; Mediratta, Anuj; Pieper, Karen; Reyes, Eric; Bonow, Robert O; Park, Seung-Jung; Beohar, Nirat

    2010-06-01

    We undertook a meta-analysis to assess outcomes for drug-eluting stents (DES) and bare-metal stents (BMS) in percutaneous coronary intervention for unprotected left main coronary artery (ULMCA) stenosis. Uncertainty exists regarding the relative performance of DES versus BMS in percutaneous coronary intervention for unprotected left main coronary stenosis. Of a total of 838 studies, 44 met inclusion criteria (n = 10,342). The co-primary end points were mortality, myocardial infarction (MI), target vessel/lesion revascularization (TVR/TLR), and major adverse cardiac events (MACE: mortality, MI, TVR/TLR). Event rates for DES and BMS were calculated at 6 to 12 months, at 2 years, and at 3 years. Crude event rates at 3 years were mortality (8.8% and 12.7%), MI (4.0% and 3.4%), TVR/TLR (8.0% and 16.4%), and MACE (21.4% and 31.6%). Nine studies were included in a comparative analysis (n = 5,081). At 6 to 12 months the adjusted odds ratio (OR) for DES versus BMS were: mortality 0.94 (95% confidence interval [CI]: 0.06 to 15.48; p = 0.97), MI 0.64 (95% CI: 0.19 to 2.17; p = 0.47), TVR/TLR 0.10 (95% CI: 0.01 to 0.84; p = 0.01), and MACE 0.34 (95% CI: 0.15 to 0.78; p = 0.01). At 2 years, the OR for DES versus BMS were: mortality 0.42 (95% CI: 0.28 to 0.62; p < 0.01), MI 0.16 (95% CI: 0.01 to 3.53; p = 0.13), and MACE 0.31 (95% CI: 0.15 to 0.66; p < 0.01). At 3 years, the OR for DES versus BMS were: mortality 0.70 (95% CI: 0.53 to 0.92; p = 0.01), MI 0.49 (95% CI: 0.26 to 0.92; p = 0.03), TVR/TLR 0.46 (95% CI: 0.30 to 0.69; p < 0.01), and MACE 0.78 (95% CI: 0.57 to 1.07; p = 0.12). Our meta-analysis suggests that DES is associated with favorable outcomes for mortality, MI, TVR/TLR, and MACE as compared to BMS in percutaneous coronary intervention for unprotected left main coronary artery stenosis. Copyright 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  16. Hospital and operator variations in drug-eluting stent use: a multi-level analysis of 5967 consecutive patients in Scotland.

    PubMed

    Austin, David; Oldroyd, Keith G; McConnachie, Alex; Slack, Rachel; Eteiba, Hany; Flapan, Andrew D; Jennings, Kevin P; Northcote, Robin J; Pell, Alistair C H; Starkey, Ian R; Pell, Jill P

    2008-06-01

    To determine whether drug-eluting stent (DES) use varies among Scottish hospitals, and the extent to which any variations are explained by differences between operators, patients and lesions. Multi-level analysis of consecutive patients treated with percutaneous coronary intervention (PCI) between April 2005 and March 2006 in Scotland, using the Scottish Coronary Revascularization Registry. A total of 38 operators performed 5967 PCI procedures on 8489 lesions. Crude level of DES use was 47.6%, and the results varied among hospitals (range 30.6-61.8%, chi(2) = 341.6, P < 0.0001). There was significant between-operator variation in the null model. This was attenuated by the addition of hospital as a fixed effect. Nonetheless, the final model demonstrated significant between-operator variability [sigma(2) = 0.486 (0.249-0.971)] and between-hospital variation, after case-mix adjustment. Within Scotland, marked variation existed among hospitals in the use of DES. Operator was the most important factor at patient level, and hospital of treatment, rather than case-mix, was the most important modifier of between-operator variation. Patient selection for DES is complex and may contribute to much of the variations demonstrated. Consensus criteria would provide more detail than is included in current guidance, may aid decision-making for individual patients, reduce opportunity costs and ensure equity of access.

  17. Everolimus-Eluting Bioresorbable Scaffolds for Coronary Artery Disease.

    PubMed

    Ellis, Stephen G; Kereiakes, Dean J; Metzger, D Christopher; Caputo, Ronald P; Rizik, David G; Teirstein, Paul S; Litt, Marc R; Kini, Annapoorna; Kabour, Ameer; Marx, Steven O; Popma, Jeffrey J; McGreevy, Robert; Zhang, Zhen; Simonton, Charles; Stone, Gregg W

    2015-11-12

    In patients with coronary artery disease who receive metallic drug-eluting coronary stents, adverse events such as late target-lesion failure may be related in part to the persistent presence of the metallic stent frame in the coronary-vessel wall. Bioresorbable vascular scaffolds have been developed to attempt to improve long-term outcomes. In this large, multicenter, randomized trial, 2008 patients with stable or unstable angina were randomly assigned in a 2:1 ratio to receive an everolimus-eluting bioresorbable vascular (Absorb) scaffold (1322 patients) or an everolimus-eluting cobalt-chromium (Xience) stent (686 patients). The primary end point, which was tested for both noninferiority (margin, 4.5 percentage points for the risk difference) and superiority, was target-lesion failure (cardiac death, target-vessel myocardial infarction, or ischemia-driven target-lesion revascularization) at 1 year. Target-lesion failure at 1 year occurred in 7.8% of patients in the Absorb group and in 6.1% of patients in the Xience group (difference, 1.7 percentage points; 95% confidence interval, -0.5 to 3.9; P=0.007 for noninferiority and P=0.16 for superiority). There was no significant difference between the Absorb group and the Xience group in rates of cardiac death (0.6% and 0.1%, respectively; P=0.29), target-vessel myocardial infarction (6.0% and 4.6%, respectively; P=0.18), or ischemia-driven target-lesion revascularization (3.0% and 2.5%, respectively; P=0.50). Device thrombosis within 1 year occurred in 1.5% of patients in the Absorb group and in 0.7% of patients in the Xience group (P=0.13). In this large-scale, randomized trial, treatment of noncomplex obstructive coronary artery disease with an everolimus-eluting bioresorbable vascular scaffold, as compared with an everolimus-eluting cobalt-chromium stent, was within the prespecified margin for noninferiority with respect to target-lesion failure at 1 year. (Funded by Abbott Vascular; ABSORB III Clinical

  18. A Drug-Eluting Contact Lens

    PubMed Central

    Ciolino, Joseph B.; Hoare, Todd R.; Iwata, Naomi G.; Behlau, Irmgard; Dohlman, Claes H.; Langer, Robert; Kohane, Daniel S.

    2014-01-01

    Purpose To formulate and characterize a drug-eluting contact lens designed to provide extended, controlled release of a drug. Methods Prototype contact lenses were created by coating PLGA (poly[lactic-co-glycolic acid]) films containing test compounds with pHEMA (poly[hydroxyethyl methacrylate]) by ultraviolet light polymerization. The films, containing encapsulated fluorescein or ciprofloxacin, were characterized by scanning electron microscopy. Release studies were conducted in phosphate-buffered saline at 37°C with continuous shaking. Ciprofloxacin eluted from the contact lens was studied in an antimicrobial assay to verify antimicrobial effectiveness. Results After a brief and minimal initial burst, the prototype contact lenses demonstrated controlled release of the molecules studied, with zero-order release kinetics under infinite sink conditions for over 4 weeks. The rate of drug release was controlled by changing either the ratio of drug to PLGA or the molecular mass of the PLGA used. Both the PLGA and the pHEMA affected release kinetics. Ciprofloxacin released from the contact lenses inhibited ciprofloxacin-sensitive Staphylococcus aureus at all time-points tested. Conclusions A prototype contact lens for sustained drug release consisting of a thin drug-PLGA film coated with pHEMA could be used as a platform for ocular drug delivery with widespread therapeutic applications. PMID:19136709

  19. Adjunctive stent use during endovascular intervention to the femoropopliteal artery with drug coated balloons: Insights from the XLPAD registry.

    PubMed

    Kokkinidis, Damianos G; Jeon-Slaughter, Haekyung; Khalili, Houman; Brilakis, Emmanouil S; Shammas, Nicolas W; Banerjee, Subhash; Armstrong, Ehrin J

    2018-06-01

    With growing use of drug-coated balloons (DCB) for femoropopliteal (FP) artery interventions, there is limited information on rates of real-world adjunctive stent use and its association with short and long-term outcomes. We report on 225 DCB treated FP lesions in 224 patients from the Excellence in Peripheral Artery Disease (XLPAD) registry (NCT01904851) between 2014 and 2016. Cochran-Mantel-Haenszel and Wilcoxon rank sum statistics were used to compare stented (planned or 'bail-out') versus non-stented DCB treated lesions. Stents were implanted in 31% of FP DCB interventions. Among the 70 stents implanted, 46% were for 'bail-out' indications and 54% were planned. Lesions treated with stents were longer (mean 150 mm vs 100 mm; p < 0.001) and less likely to be in-stent restenosis lesions (10% vs 28%; p=0.003). Stenting was significantly more frequent in complex FP lesions, including chronic total occlusions (66% vs 34%; p < 0.001). For bail-out stenting, interwoven nitinol stents were the most common type (50%) followed by drug-eluting stents (34%) and bare-metal stents (22%). There were no differences in peri-procedural complication rates or 12-month target limb revascularization rates (18.6% vs 11.6%; p=0.162) or 12-month amputation rates (11.4% vs 11%; p=0.92) between lesions where adjunctive stenting was used versus lesions without adjunctive stenting, respectively. In conclusion, in a contemporary 'real-world' adjudicated multicenter US registry, adjunctive stenting was necessary in nearly a third of the lesions, primarily for the treatment of more complex FP lesions, with similar short and intermediate-term clinical outcomes compared with non-stented lesions.

  20. A prospective, multicenter, post marketing surveillance study to evaluate the safety and effectiveness of the Superia-Sirolimus Eluting Coronary Stent System (SSECSS) implanted during routine clinical practice in India.

    PubMed

    Chandra, Praveen; Kumar, Tarun

    2014-01-01

    A prospective, multicenter, post marketing surveillance study to evaluate the safety and effectiveness of the Superia-Sirolimus Eluting Coronary Stent System (SSECSS) implanted during routine clinical practice in India. 1. To study the MACE and in stent and In-segment Loss at Six Months (in a pre selected group of 50 patients). 1. Clinical and procedural success. This is a prospective, open label, single-arm, multicenter (16 sites), post marketing observational study enrolling patients implanted with Superia-Sirolimus Eluting Coronary Stent (SSECS) in routine clinical practice in India. A total of 200 Patients of coronary Artery Disease (CAD) implanted with Superia-Sirolimus Eluting Coronary Stent (SSECS) were enrolled. Clinical assessments were done at 30 days, 180 days and at 1, 2 years either telephonically or office visit. A cohort of 50 pre-selected patients were followed up for angiographic evaluation at 180 days. MACE at 12 month of follow up was 1.71%.Late lumen loss, in segment was 0.14 and in stent was 0.10 mm at 6 month of follow-up. TLR was required only in 2 patients. Superia stent is as safe as other biodegradable polymer stent in the market and time has come for biodegradable polymer stent with thin struts. Copyright © 2014 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  1. Learning from the Cardiologists and Developing Eluting Stents Targeting the Mtor Pathway for Pulmonary Application; A Future Concept for Tracheal Stenosis

    PubMed Central

    Zarogoulidis, Paul; Darwiche, Kaid; Tsakiridis, Kosmas; Teschler, Helmut; Yarmus, Lonny; Zarogoulidis, Konstantinos; Freitag, Lutz

    2014-01-01

    Tracheal stenosis due to either benign or malignant disease is a situation that the pulmonary physicians and thoracic surgeons have to cope in their everyday clinical practice. In the case where tracheal stenosis is caused due to malignancy mini-interventional interventions with laser, apc, cryoprobe, balloon dilation or with combination of more than one equipment and technique can be used. On the other hand, in the case of a benign disease such as; tracheomalacia the clinician can immediately upon diagnosis proceed to the stent placement. In both situations however; it has been observed that the stents induce formation of granuloma tissue in both or one end of the stent. Therefore a frequent evaluation of the patient is necessary, taking also into account the nature of the primary disease. Evaluation methodologies identifying different types and extent of the trachea stenosis have been previously published. However; we still do not have an effective adjuvant therapy to prevent granuloma tissue formation or prolong already treated granuloma lesions. There have been proposed many mechanisms which induce the abnormal growth of the local tissue, such as; local pressure, local stress, inflammation and vascular endothelial growth factor overexpression. Immunomodulatory agents inhibiting the mTOR pathway are capable of inhibiting the inflammatory cascade locally. In the current mini-review we will try to present the current knowledge of drug eluting stents inhibiting the mTOR pathway and propose a future application of these stents as a local anti-proliferative treatment. PMID:24454525

  2. Learning from the Cardiologists and Developing Eluting Stents Targeting the Mtor Pathway for Pulmonary Application; A Future Concept for Tracheal Stenosis.

    PubMed

    Zarogoulidis, Paul; Darwiche, Kaid; Tsakiridis, Kosmas; Teschler, Helmut; Yarmus, Lonny; Zarogoulidis, Konstantinos; Freitag, Lutz

    2013-08-26

    Tracheal stenosis due to either benign or malignant disease is a situation that the pulmonary physicians and thoracic surgeons have to cope in their everyday clinical practice. In the case where tracheal stenosis is caused due to malignancy mini-interventional interventions with laser, apc, cryoprobe, balloon dilation or with combination of more than one equipment and technique can be used. On the other hand, in the case of a benign disease such as; tracheomalacia the clinician can immediately upon diagnosis proceed to the stent placement. In both situations however; it has been observed that the stents induce formation of granuloma tissue in both or one end of the stent. Therefore a frequent evaluation of the patient is necessary, taking also into account the nature of the primary disease. Evaluation methodologies identifying different types and extent of the trachea stenosis have been previously published. However; we still do not have an effective adjuvant therapy to prevent granuloma tissue formation or prolong already treated granuloma lesions. There have been proposed many mechanisms which induce the abnormal growth of the local tissue, such as; local pressure, local stress, inflammation and vascular endothelial growth factor overexpression. Immunomodulatory agents inhibiting the mTOR pathway are capable of inhibiting the inflammatory cascade locally. In the current mini-review we will try to present the current knowledge of drug eluting stents inhibiting the mTOR pathway and propose a future application of these stents as a local anti-proliferative treatment.

  3. Randomized Comparison of Paclitaxel-Eluting Balloon and Stenting Versus Plain Balloon Plus Stenting Versus Directional Atherectomy for Femoral Artery Disease (ISAR-STATH).

    PubMed

    Ott, Ilka; Cassese, Salvatore; Groha, Philipp; Steppich, Birgit; Hadamitzky, Martin; Ibrahim, Tareq; Kufner, Sebastian; Dewitz, Karl; Hiendlmayer, Regina; Laugwitz, Karl-Ludwig; Schunkert, Heribert; Kastrati, Adnan; Fusaro, Massimiliano

    2017-06-06

    Atherosclerosis in the superficial femoral artery is common in patients suffering from peripheral artery disease. Paclitaxel-eluting balloon (PEB) angioplasty, stenting, and directional atherectomy (DA) have provided new options for the treatment of superficial femoral artery disease; however, the comparative efficacy of these interventional strategies remains uncertain. One hundred and fifty-five patients with symptomatic peripheral artery disease due to de novo superficial femoral artery stenotic or occlusive lesions were randomized to treatment with plain balloon angioplasty (BA) followed by PEB angioplasty and stenting (n=48), BA and stenting (n=52), or DA with distal protection and bailout stenting (n=55). The primary end point of the study was percentage diameter stenosis after 6 months measured by angiography. Other end points included target lesion revascularization, thrombosis, ipsilateral amputation, binary restenosis, and all-cause mortality at 6 and 24 months. Baseline and lesion characteristics were comparable in all groups with a mean lesion length of 65.9±46.8 mm and 56% total occlusions. At 6 months angiography, the percent diameter stenosis was significantly lower in patients treated by PEB angioplasty and stenting (34±31%) as compared with BA angioplasty and stenting (56±29%, P =0.009) or DA (55±29%, P =0.007). Similarly, binary restenosis was significantly lower after treatment with PEB and stenting as compared with BA and stenting or DA. Clinical follow-up at 24 months revealed a lower risk for target lesion revascularization after PEB angioplasty and stenting as compared with BA and stenting or DA. We found no difference in terms of target lesion thrombosis and mortality among groups, and no patient underwent amputation. Treatment of de novo superficial femoral artery lesions with PEB angioplasty and stenting is superior to BA angioplasty and stenting or DA in terms of angiographic diameter stenosis at 6 months and target lesion

  4. Controlled delivery of paclitaxel from stent coatings using poly(hydroxystyrene-b-isobutylene-b-hydroxystyrene) and its acetylated derivative.

    PubMed

    Sipos, Laszlo; Som, Abhijit; Faust, Rudolf; Richard, Robert; Schwarz, Marlene; Ranade, Shrirang; Boden, Mark; Chan, Ken

    2005-01-01

    A poly(styrene-b-isobutylene-b-styrene) (SIBS) triblock polymer is employed as the polymer drug carrier for the TAXUS Express2 Paclitaxel-Eluting Coronary Stent system (Boston Scientific Corp.). It has been shown that the release of paclitaxel (PTx) from SIBS can be modulated by modification of either drug-loading ratio or altering the triblock morphology by blending. In the present work, results toward achieving release modulation of PTx by chemical modification of the styrenic portion (using hydroxystyrene or its acetylated version) of the SIBS polymer system are reported. The synthesis of the precursor poly[(p-tert-butyldimethylsilyloxystyrene)]-b-isobutylene-b-[(p-tert-butyldimethylsilyloxystyrene] triblock copolymers was accomplished by living sequential block copolymerization of isobutylene (IB) and p-(tert-butyldimethylsiloxy)styrene (TBDMS) utilizing the capping-tuning technique in a one-pot procedure in methylcyclohexane/CH3Cl at -80 degrees C. This procedure involved the living cationic polymerization of IB with the 5-tert-butyl-1,3-bis(1-chloro-1-methylethyl)benzene/TiCl4 initiating system and capping of living difunctional polyisobutylene (PIB) chain ends with 1,1-ditolylethylene (DTE) followed by addition of titanium(IV) isopropoxide (Ti(OIp)4) to lower the Lewis acidity before the introduction of TBDMS. Deprotection of the product with tetrabutylammonium fluoride yielded poly(hydroxystyrene-b-isobutylene-b-hydroxystyrene), which was quantitatively acetylated to obtain the acetylated derivative. The hydroxystyrene and acetoxystyrene triblock copolymers have acceptable mechanical properties for use as drug delivery coatings for coronary stent applications. It was concluded that the hydrophilic nature of the endblocks and polarity effects on the drug/polymer miscibility lead to enhanced release of PTx from these polymers. The drug-polymer miscibility was confirmed by differential scanning calorimetry and atomic force microscopy evaluations.

  5. Edge-to-Edge Technique to Minimize Ovelapping of Multiple Bioresorbable Scaffolds Plus Drug Eluting Stents in Revascularization of Long Diffuse Left Anterior Descending Coronary Artery Disease.

    PubMed

    Rigatelli, Gianluca; Avvocata, Fabio Dell'; Ronco, Federico; Giordan, Massimo; Roncon, Loris; Caprioglio, Francesco; Grassi, Giuseppe; Faggian, Giuseppe; Cardaioli, Paolo

    2016-06-01

    Implantation of Drug Eluting Stents (DES) plus bioresorbable scaffolds (BVS) in very long diffuse left anterior descending coronary artery (LAD) disease may be problematic because of multiple devices overlapping. We sought to assess the short and mid-tern outcomes of combined implantation of DES and BVS using a novel "edge-to-edge" technique in patients with diffuse LAD disease. Patients with long diffuse LAD disease were enrolled in a prospective registry from 1st August 2014 to 1st August 2015 and treated with IVUS-aided percutaneous coronary intervention using a DES plus a single or multiple BVS using a novel "edge-to-edge" technique. Clinical follow up and invasive follow up driven by clinical justification was performed. Twenty-three patients (5 females, mean age 59.1± 9.1 years) were enrolled. Mean length of LAD disease was 73.1 ± 20.6 mm. Mean number of DES and BVS implanted was 1.2 ± 0.4 and 1.7 ± 1.3, respectively. At a mean follow-up of 11.3 ± 3.8 months, no stent thrombosis or MACE were observed. Angiographic and IVUS follow-up at a mean of 6.6 ± 0.7 months showed no significant angiographic restenosis and no appreciable stent gaps. In revascularization of long diffuse disease of the LAD, the edge-to-edge implantation technique appears to be feasible resulting in no restenosis or thrombosis on the short-term follow-up. (J Interven Cardiol 2016;29:275-284). © 2016, Wiley Periodicals, Inc.

  6. Prevention of stent thrombosis: challenges and solutions

    PubMed Central

    Reejhsinghani, Risheen; Lotfi, Amir S

    2015-01-01

    Stent thrombosis is an uncommon but serious complication which carries with it significant mortality and morbidity. This review analyzes the entity of stent thrombosis from a historical and clinical perspective, and chronicles the evolution of this condition through the various generations of stent development, from bare metal to first-generation, second-generation, and third-generation drug-eluting stents. It also delineates the specific risk factors associated with stent thrombosis and comprehensively examines the literature related to each of these risks. Finally, it highlights the preventative strategies that can be garnered from the existing data, and concludes that a multifactorial approach is necessary to combat the occurrence of stent thrombosis, with higher risk groups, such as patients with ST segment elevation myocardial infarction, meriting further research. PMID:25657588

  7. Optical Coherence Tomography Findings in Patients With Stent Thrombosis.

    PubMed

    Cuesta, Javier; Rivero, Fernando; Bastante, Teresa; García-Guimaraes, Marcos; Antuña, Paula; Alvarado, Teresa; Navarrete, Gonzalo; Benedicto, Amparo; Alfonso, Fernando

    2017-12-01

    Stent thrombosis (ST) is a rare but potentially serious complication. Optical coherence tomography (OCT) provides high-resolution images and additional information to angiography in the study of this event. Prospective study of patients with ST undergoing reintervention with OCT imaging. The study included a total of 40 consecutive patients with ST. Mean age was 69 ± 13 years and 83% were male. Early ST (≤ 30 days) was observed in 16 patients and late ST (> 30 days) in 24 patients. Stent thrombosis occurred in 17 bare-metal stents and 23 drug-eluting stents. In 34 patients (85%), adequate OCT images were obtained at the time of the ST. The predominant mechanism in early ST was stent malapposition (39%). In late ST, high frequencies of uncovered (46%) and malapposed struts (17%) were observed, especially in patients with drug-eluting stents. Furthermore, the presence of neoatherosclerosis was very high (67%) in patients with late ST. After intervention, improvements were observed in malapposition length and the amount of residual thrombus. OCT allows identification of the underlying mechanisms potentially involved in ST. This imaging modality is helpful in guiding reintervention in these patients, which improves the area and length of malapposition, as well as the maximal residual thrombus area. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  8. Effectiveness of two-year clopidogrel + aspirin in abolishing the risk of very late thrombosis after drug-eluting stent implantation (from the TYCOON [two-year ClOpidOgrel need] study).

    PubMed

    Tanzilli, Gaetano; Greco, Cesare; Pelliccia, Francesco; Pasceri, Vincenzo; Barillà, Francesco; Paravati, Vincenzo; Pannitteri, Gaetano; Gaudio, Carlo; Mangieri, Enrico

    2009-11-15

    It remains unclear whether dual antiplatelet therapy >12 months might carry a better prognosis after percutaneous coronary intervention (PCI) with drug-eluting stents (DESs). To address the hypothesis that in the real world the risk of very late thrombosis after PCI with DESs can be decreased by an extended use of clopidogrel, we set up the Two-Year ClOpidOgrel Need (TYCOON) registry and prospectively investigated the impact on very late thrombosis of 12- versus 24-month dual antiplatelet regimens in an unselected population. The registry enrolled 897 consecutive patients who underwent PCI with stenting from January 1, 2003, to December 31, 2004, and had dual antiplatelet therapy. All patients had a 4-year clinical follow-up. In the 447 patients with DES implantation, the dual antiplatelet regimen after PCI was given for 12 months in the 173 patients treated in 2003 (12-month group) and for 24 months in the 274 patients treated in 2004 (24-month group). Comparison between groups did not reveal any significant difference in baseline clinical characteristics, angiographic and procedural features, and major adverse cardiac events. During follow-up, there were 5 cases of stent thrombosis after PCI in the 12-month DES group and 1 case in the 24-month DES group (p = 0.02). Specifically, there were 2 cases of subacute thrombosis (1 in each group), no case of late thrombosis, and 4 cases of very late thrombosis occurring at 13, 15, 17, and 23 months after DES implantation in the 12-month group only. In conclusion, a 2-year dual antiplatelet regimen with aspirin and clopidogrel can prevent the occurrence of very late stent thrombosis after PCI with DESs.

  9. Taxus ingredients in the red arils of Taxus baccata L. determined by HPLC-MS/MS.

    PubMed

    Siegle, Lydia; Pietsch, Jörg

    2018-02-09

    Taxus baccata L. is an evergreen conifer whose plant parts are cardiotoxic. Only the red arils of the berries are described as non-toxic and taxane-free. Extraction and HPLC-MS/MS methods were developed for the investigation of the Taxus compounds 3,5-dimethoxyphenol, 10-deacetylbaccatin III, baccatin III, cephalomannine, taxol A and taxinine M in the red arils of the yew berries. MethodologyA liquid-liquid extraction method for the red arils of the fruits from three yews were developed. An accurate (ESI+) HPLC-MS/MS method was performed for the simultaneous detection and determination of the target compounds in multiple reaction monitoring (MRM) mode. All Taxus agents obtained were detected in the red arils. Highest concentrations were determined for baccatin III and 10-deacetylbaccatin III. The developed quantitative method is reliable and selective and was successfully applied for quantification of selected Taxus ingredients in red arils of Taxus baccata. It was disproved that the red arils of the berries do not contain the selected Taxus compounds. Copyright © 2018 John Wiley & Sons, Ltd.

  10. Triple antithrombotic therapy versus dual antiplatelet therapy in patients with atrial fibrillation undergoing drug-eluting stent implantation.

    PubMed

    Kang, Dong Oh; Yu, Cheol Woong; Kim, Hee Dong; Cho, Jae Young; Joo, Hyung Joon; Choi, Rak Kyong; Park, Jin Sik; Lee, Hyun Jong; Kim, Je Sang; Park, Jae Hyung; Hong, Soon Jun; Lim, Do-Sun

    2015-08-01

    The optimal antithrombotic regimen in patients with atrial fibrillation (AF) undergoing drug-eluting stent (DES) implantation for complex coronary artery disease is unclear. We compared the net clinical outcomes of triple antithrombotic therapy (TAT; aspirin, thienopyridine, and warfarin) and dual antiplatelet therapy (DAPT; aspirin and thienopyridine) in AF patients who had undergone DES implantation. A total of 367 patients were enrolled and analyzed retrospectively; 131 patients (35.7%) received TAT and 236 patients (64.3%) received DAPT. DAPT and warfarin were maintained for a minimum of 12 and 24 months, respectively. The primary endpoint was the 2-year net clinical outcomes, a composite of major bleeding and major adverse cardiac and cerebral events (MACCE). Propensity score-matching analysis was carried out in 99 patient pairs. The 2-year net clinical outcomes of the TAT group were worse than those of the DAPT group (34.3 vs. 21.1%, P=0.006), which was mainly due to the higher incidence of major bleeding (16.7 vs. 4.6%, P<0.001), without any significant increase in MACCE (22.1 vs. 17.7%, P=0.313). In the multivariate analysis, TAT was an independent predictor of worse net clinical outcomes (odds ratio 1.63, 95% confidence interval 1.06-2.50) and major bleeding (odds ratio 3.54, 95% confidence interval 1.65-7.58). After propensity score matching, the TAT group still had worse net clinical outcomes and a higher incidence of major bleeding compared with the DAPT group. In AF patients undergoing DES implantation, prolonged administration of TAT may be harmful due to the substantial increase in the risk for major bleeding without any reduction in MACCE.

  11. Direct stenting versus balloon predilation: Jury is still out.

    PubMed

    Belardi, Jorge A; Albertal, Mariano

    2017-08-01

    Compared to balloon predilation, direct stenting (DS) shortens procedural time and reduces radiation and contrast exposure. A meta-analysis that included 7 studies comparing these 2 strategies revealed lower adverse event rate with DS. Studies included in the present meta-analysis were mostly observational and utilized first generation drug-eluting stent. Patient and lesion selection may explain these positive results. © 2017 Wiley Periodicals, Inc.

  12. Drug-Eluting Nitinol Stent Treatment of the Superficial Femoral Artery and Above-the-Knee Popliteal Artery (The Zilver PTX Single-Arm Clinical Study): A Comparison Between Diabetic and Nondiabetic Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fanelli, Fabrizio, E-mail: fabrizio.fanelli@uniroma1.it; Primo, Massimiliano Di; Boatta, Emanuele

    2013-10-15

    Purpose: To describe the 1-year results of drug-eluting nitinol stent placement in the femoropopliteal artery of diabetic and nondiabetic patients. Materials and Methods: All patients enrolled in this prospective, multicenter study underwent paclitaxel-eluting stent placement for de novo or restenotic lesions of the superficial femoral and/or popliteal artery. Baseline and follow-up walking impairment questionnaire (WIQ) scores, Rutherford classifications, and ankle-brachial index (ABI) measurements were obtained. Follow-up was completed at 1, 6, and 12 months. Results: There were 285 diabetic patients and 502 nondiabetic patients treated. There were no significant differences in mean lesion length or lesion calcification between patient groups.more » Procedural success in both treatment groups was >97 %. There were no significant differences between diabetic and nondiabetic groups in Kaplan-Meier estimates of patency, event-free survival (EFS), or freedom from target lesion revascularization (TLR) at 6 and 12 months. Both groups experienced a significant increase in ABI and WIQ values after treatment, and these improvements were sustained to 12-month follow-up; however, nondiabetic patients had significantly greater 6- and 12-month WIQ scores compared with diabetic patients. Based on covariate analysis, the only factors shown to be significant and to negatively influence patency were longer lesion length (p = 0.009), higher Rutherford classification (p = 0.02), and lack of hypertension (p = 0.02); diabetic status was not found to be a significant factor. Conclusion: Diabetic and nondiabetic patients had similar estimates of primary patency, EFS, and freedom from TLR; however, diabetic patients showed less improvement in WIQ scores compared with nondiabetic patients.« less

  13. Safety and efficacy of the next generation Resolute Onyx zotarolimus-eluting stent: Primary outcome of the RESOLUTE ONYX core trial.

    PubMed

    Price, Matthew J; Shlofmitz, Richard A; Spriggs, Douglas J; Haldis, Thomas A; Myers, Paul; Popma Almonacid, Alexandra; Maehara, Akiko; Dauler, Michelle; Peng, Yun; Mehran, Roxana

    2017-09-23

    To assess the safety and efficacy of the novel Resolute (R-) Onyx drug-eluting stent (DES). The R-Onyx DES consists of a composite wire with an outer shell of cobalt chromium alloy and a platinum-iridium inner core to enhance radiopacity, with thinner, swaged struts and modified stent geometry compared with the predicate Resolute DES, resulting in a slightly lower total drug load in most sizes. This was a prospective, single-arm non-inferiority trial compared with a historical control. Patients with stable angina/ischemia and up to 2 de novo target lesions ≤35 mm long with reference vessel diameter (RVD) of 2.25-4.2 mm were enrolled. The primary endpoint was late lumen loss at 8-month follow-up. Propensity-score adjusted outcomes from the single-arm RESOLUTE-US trial served as the control. Seventy-five patients (85 lesions) were enrolled. Mean patient age was 66 ± 9 years, 73% were male, and 32% had diabetes. Mean lesion length was 14.28 ± 6.68 mm, mean RVD was 2.57 ± 0.48 mm, and 86% of lesions were class B2/C. In-stent late lumen loss at 8 months was 0.24 ± 0.39 mm with R-Onyx DES compared with 0.36 ± 0.52 mm with Resolute DES (P < 0.001 for noninferiority, P = 0.029 for superiority). At 8 months, clinically driven target lesion revascularization occurred in 3 patients (4.0%) and target lesion failure occurred in 5 patients (6.7%). In-stent late lumen loss is non-inferior, and appears to be superior, with the thin-strut novel composite wire R-Onyx DES compared with Resolute DES. Continued evolution of stent design can improve angiographic outcomes in complex lesions, even in the current era of next-generation DES. © 2017 Wiley Periodicals, Inc.

  14. The 'Harmonizing Optimal Strategy for Treatment of coronary artery stenosis - sAfety & effectiveneSS of drug-elUting stents & antiplatelet REgimen' (HOST-ASSURE) trial: study protocol for a randomized controlled trial

    PubMed Central

    2012-01-01

    Background Second-generation drug-eluting stents (DES) have raised the bar of clinical performance. These stents are mostly made from cobalt chromium alloy. A newer generation DES has been developed from platinum chromium alloy, but clinical data regarding the efficacy and safety of the platinum chromium-based everolimus-eluting stent (PtCr-EES) is limited, with no comparison data against the cobalt chromium-based zotarolimus-eluting stent (CoCr-ZES). In addition, an antiplatelet regimen is an integral component of medical therapy after percutaneous coronary intervention (PCI). A 1-week duration of doubling the dose of clopidogrel (double-dose antiplatelet therapy (DDAT)) was shown to improve outcome at 1 month compared with conventional dose in acute coronary syndrome (ACS) patients undergoing PCI. However in Asia, including Korea, the addition of cilostazol (triplet antiplatelet therapy (TAT)) is used more commonly than doubling the dose of clopidogrel in high-risk patients. Methods In the 'Harmonizing Optimal Strategy for Treatment of coronary artery stenosis - sAfety & effectiveneSS of drug-elUting stents & antiplatelet REgimen' (HOST-ASSURE) trial, approximately 3,750 patients are being prospectively and randomly assigned in a 2 × 2 factorial design according to the type of stent (PtCr-EES vs CoCr-ZES) and antiplatelet regimen (TAT vs DDAT). The first primary endpoint is target lesion failure at 1 year for the stent comparison, and the second primary endpoint is net clinical outcome at 1 month for comparison of antiplatelet therapy regimen. Discussion The HOST-ASSURE trial is the largest study yet performed to directly compare the efficacy and safety of the PtCr-EES versus CoCr-ZES in an 'all-comers' population. In addition, this study will also compare the clinical outcome of TAT versus DDAT for 1-month post PCI. Trial registration ClincalTrials.gov number NCT01267734. PMID:22463698

  15. Efficacy of a Dexamethasone-Eluting Nitinol Stent on the Inhibition of Pseudointimal Hyperplasia in a Transjugular Intrahepatic Portosystemic Shunt: An Experimental Study in a Swine Model

    PubMed Central

    Seo, Tae-Seok; Park, Young-Koo; Song, Ho-Young; Park, Sang Joon; Yuk, Sun-Hong

    2005-01-01

    Objective We wanted to evaluate the feasibility and efficacy of using a dexamethasone (DM)-eluting nitinol stent to inhibit the pseudointimal hyperplasia following stent placement in the transjugular intrahepatic portosystemic shunt tract (TIPS) of a swine. Materials and Methods Fifteen stents were constructed using 0.15 mm-thick nitinol wire; they were 60 mm in length and 10 mm in diameter. The metallic stents were then classified into three types; type 1 and 2 was coated with the mixture of 12% and 20%, respectively, of DM solution and polyurethane (PU), while type 3 was a bare stent that was used for control study. In fifteen swine, each type of stent was implanted in the TIPS tract of 5 swine, and each animal was sacrificed 2 weeks after TIPS creation. The proliferation of the pseudointima was evaluated both on follow-up portogram and pathologic examination. Results One TIPS case, using the type 1 stent, and two TIPS cases, using the type 2 stent, maintained their luminal patency while the others were all occluded. On the histopathologic analysis, the mean of the maximum pseudointimal hyperplasia was expressed as the percentage of the stent radius that was patent, and these values were 51.2%, 50% and 76% for the type 1, 2, and 3 stents, respectively. Conclusion The DM-eluting stent showed a tendency to reduce the development of pseudointimal hyperplasia in the TIPS tract of a swine model with induced-portal hypertension. PMID:16374082

  16. Current evidence for the safety and efficacy of the bio-engineered dual therapy COMBO stent.

    PubMed

    Kalkman, Deborah N; Chandrasekhar, Jaya; de Winter, Robbert J; Mehran, Roxana

    2018-06-01

    The novel dual-therapy COMBO stent aims to promote vessel healing after percutaneous coronary intervention (PCI) in patients with coronary artery disease. The pro-healing technique consists of an anti-CD34+ antibody layer that attracts circulating endothelial progenitor cells (EPCs), which bind to the stent surface and allow rapid endothelialization by differentiation of the EPCs into normal endothelial cells. The COMBO stent combines this pro-healing technique with an abluminal drug elution of sirolimus. The promise of this dual-therapy stent is that it may safely allow a shortened duration of dual-antiplatelet therapy (DAPT) after stent placement. Moreover, with a mature endothelial layer, lower rates of in-stent restenosis may be expected. Clinical outcomes after COMBO stent implantation have been recently evaluated in both randomized trials and large, prospective, multicenter registries, showing low clinical event rates of in-stent restenosis and stent thrombosis. Randomized clinical trials (HARMONEE and RECOVERY) have demonstrated the non-inferiority of COMBO versus "first in class" second generation and newer generation drug-eluting stents. Safety and efficacy of 3 months of DAPT after COMBO stent placement in patients presenting with acute coronary syndrome has been evaluated in the large REDUCE randomized controlled trial, showing non-inferiority to standard duration of 12-month DAPT. In this review we provide an overview of the current pre-clinical and clinical evidence for the performance of the COMBO stent.

  17. Systematic Review of Infrapopliteal Drug-Eluting Stents: A Meta-Analysis of Randomized Controlled Trials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr; Spiliopoulos, Stavros; Diamantopoulos, Athanasios

    2013-06-15

    IntroductionDrug-eluting stents (DES) have been proposed for the treatment of infrapopliteal arterial disease. We performed a systematic review to provide a qualitative analysis and quantitative data synthesis of randomized controlled trials (RCTs) assessing infrapopliteal DES.Materials and MethodsPubMed (Medline), EMBASE (Excerpta Medical Database), AMED (Allied and Complementary medicine Database), Scopus, CENTRAL (Cochrane Central Register of Controlled Trials), online content, and abstract meetings were searched in September 2012 for eligible RCTs according to the preferred reporting items for systematic reviews and meta-analyses selection process. Risk of bias was assessed using the Cochrane Collaboration's tool. Primary endpoint was primary patency defined as absencemore » of {>=}50 % vessel restenosis at 1 year. Secondary outcome measures included patient survival, limb amputations, change of Rutherford-Becker class, target lesion revascularization (TLR) events, complete wound healing, and event-free survival at 1 year. Risk ratio (RRs) were calculated using the Mantel-Haenszel fixed effects model, and number-needed-to-treat values are reported.ResultsThree RCTs involving 501 patients with focal infrapopliteal lesions were analyzed (YUKON-BTX, DESTINY, and ACHILLES trials). All three RCTs included relatively short and focal infrapopliteal lesions. At 1 year, there was clear superiority of infrapopliteal DES compared with control treatments in terms of significantly higher primary patency (80.0 vs. 58.5 %; pooled RR = 1.37, 95 % confidence interval [CI] = 1.18-1.58, p < 0.0001; number-needed-to-treat (NNT) value = 4.8), improvement of Rutherford-Becker class (79.0 vs. 69.6 %; pooled RR = 1.13, 95 % CI = 1.002-1.275, p = 0.045; NNT = 11.1), decreased TLR events (9.9 vs. 22.0 %; pooled RR = 0.45, 95 % CI = 0.28-0.73, p = 0.001; NNT = 8.3), improved wound healing (76.8 vs. 59.7 %; pooled RR = 1.29, 95 % CI = 1.02-1.62, p = 0.04; NNT = 5.9), and better overall

  18. Randomized comparison of cost-saving and effectiveness of oral rapamycin plus bare-metal stents with drug-eluting stents: three-year outcome from the randomized oral rapamycin in Argentina (ORAR) III trial.

    PubMed

    Rodriguez, Alfredo E; Rodriguez-Granillo, Alfredo M; Antoniucci, David; Mieres, Juan; Fernandez-Pereira, Carlos; Rodriguez-Granillo, Gaston A; Santaera, Omar; Rubilar, Bibiana; Palacios, Igor F; Serruys, Patrick W

    2012-09-01

    The Oral Rapamycin in ARgentina (ORAR) III trial is a randomized study comparing a strategy of oral rapamycin (OR) plus bare-metal stent (BMS) versus a strategy of drug-eluting stents (DES) in patients with de novo coronary lesions. The purpose of this study was to assess the 3 years cost-effectiveness outcome of each strategy. OR after BMS has been associated with reduction of target vessel revascularization (TVR) although its value in long-term efficacy in comparison with DES is unknown. In three hospitals in Buenos Aires, Argentina, 200 patients were randomized to OR plus BMS (n = 100) or DES (n = 100). Primary objectives were costs and effectiveness. Cost analysis included in-hospital and follow-up costs. Safety was defined as the composite of death, myocardial infarction (MI), and stroke. Efficacy was defined as TVR. Baseline characteristics between groups were similar. The 3-year follow-up rate was 99%. Cardiac mortality was 2% and 5% in OR group and DES group, respectively (P = 0.44). The composite of death, MI and stroke rate was 11% in OR group and 20% in DES group (P = 0.078). TVR rate was 14.5% in OR group and 17.6% in DES group (P = 0.50), respectively. Three year cumulative costs were significantly lower in the OR arm as compared to the DES arm (P = 0.0001) and DES strategy did not result cost-effective according to the non-inferiority test. At 3 years follow-up, there were no differences in effectiveness between the two strategies, and DES strategy was not more cost-effective as compared to OR plus BMS. Copyright © 2011 Wiley Periodicals, Inc.

  19. Outcomes of Patients Treated with the Everolimus- versus the Paclitaxel-Eluting Stents in a Consecutive Cohort of Patients at a Tertiary Medical Center.

    PubMed

    Shammas, Nicolas W; Shammas, Gail A; Nader, Elie; Jerin, Michael; Mrad, Luay; Ehrecke, Nicholas; Shammas, Waheeb J; Voelliger, Cara M; Hafez, Alexander; Kelly, Ryan; Reynolds, Emily

    2013-09-01

    In this study, we compare the outcomes of the paclitaxel-eluting stent (PES) versus the everolimus-eluting stent (EES) treated patients at a tertiary medical center and up to 2 years follow-up. Unselected consecutive patients were retrospectively recruited following stenting with PES (159 patients) or EES (189 patients). The primary endpoint of the study was target lesion failure (TLF), defined as the combined endpoint of cardiac death, nonfatal myocardial infarction (MI), or target lesion revascularization (TLR). Secondary endpoints included target vessel revascularization (TVR), TLR, target vessel failure (TVF), acute stent thrombosis (ST), total death, cardiac death, and nonfatal MI. Patients treated with the PES stent had less congestive heart failure and restenotic lesions, but a higher prevalence of longer lesions, nonleft main bifurcations, required more stents per patient (4.3 ± 2.8 vs. 2.9 ± 2.1). TLF occurred in 32.3% PES versus 21.5% EES (p = 0.027). The secondary unadjusted endpoints for PES versus EES, respectively, were TVF 38.6 versus 30.7% (p = 0.140), TVR 35.7 versus 26.5% (p = 0.079), definite and probable ST 1.2 versus 0.0%, nonfatal MI 4.5 versus 4.2%, and mortality 9.6 versus 4.0%. Logistic regression analysis showed that the numbers of stents per patient (p = 0.001), age (p = 0.01), and renal failure (p = 0.045) were independent predictors of TLF. Using univariate analysis, EES had lower TLF than PES in a cohort of unselected patients undergoing percutaneous coronary intervention at 2 years follow-up. Multivariate analysis showed that the numbers of stents per patient, age, and renal failure, but not stent type, were predictors of TLF.

  20. The NICE recommendation for drug-coated balloons and its global impact.

    PubMed

    Eccleshall, Simon; Waliszewski, M

    2015-06-01

    The clinical efficacy and safety of drug-coated balloon (DCB) angioplasty in patients with coronary in-stent restenosis (ISR) has been demonstrated. The objective of this article is to provide comparative cost efficacy data for DCB angioplasty in various countries based on the original methodology of the Medical Technologies Evaluation Programme (MTEP) at the National Institute for Health and Clinical Excellence (NICE) in 2010. Published and unpublished Health Technology Assessment (HTA) reports were evaluated for comparison in selected countries. Furthermore, a systematic review of economic evaluations of DCB angioplasty versus standard treatments (uncoated balloon angioplasty or drug-eluting stent implantations) was conducted. National cost efficacy data were evaluated using Markov state transition models which were adapted to fit each country's device and procedure related costs. The clinical input for adverse events was defined with two relevant trials for in-stent restenosis of bare metal stents (BMS-ISR) and of drug-eluting stents (DES-ISR). In the UK, Germany, Switzerland, South Africa, Japan and Brazil, DCB angioplasty is cost-effective when compared with drug-eluting stents to treat either BMS-ISR or DES-ISR. DCB angioplasty ought to be the preferred treatment option for patients with BMS-ISR and DES-ISR from the payers' point of view. © The Author(s), 2015.

  1. Favorable Outcomes after Implantation of Biodegradable Polymer Coated Sirolimus-Eluting Stents in Diabetic Population: Results from INDOLIMUS-G Diabetic Registry.

    PubMed

    Polavarapu, Anurag; Polavarapu, Raghava Sarma; Prajapati, Jayesh; Raheem, Asif; Thakkar, Kamlesh; Kothari, Shivani; Thakkar, Ashok

    2015-01-01

    Objective. The main aim is to evaluate safety, efficacy, and clinical performance of the Indolimus (Sahajanand Medical Technologies Pvt. Ltd., Surat, India) sirolimus-eluting stent in high-risk diabetic population with complex lesions. Methods. It was a multicentre, retrospective, non-randomized, single-arm study, which enrolled 372 diabetic patients treated with Indolimus. The primary endpoint of the study was major adverse cardiac events (MACE), which is a composite of cardiac death, target lesion revascularization (TLR), target vessel revascularization (TVR), myocardial infarction (MI), and stent thrombosis (ST). The clinical follow-ups were scheduled at 30 days, 6 months, and 9 months. Results. The mean age of the enrolled patients was 53.4 ± 10.2 years. A total of 437 lesions were intervened successfully with 483 stents (1.1 ± 0.3 per lesion). There were 256 (68.8%) male patients. Hypertension and totally occluded lesions were found in 202 (54.3%) and 45 (10.3%) patients, respectively. The incidence of MACE at 30 days, 6 months and 9 months was 0 (0%), 6 (1.6%), and 8 (2.2%), respectively. The event-free survival at 9-month follow-up by Kaplan Meier method was found to be 97.8%. Conclusion. The use of biodegradable polymer coated sirolimus-eluting stent is associated with favorable outcomes. The results demonstrated in our study depict its safety and efficacy in diabetic population.

  2. In-hospital management and outcome of patients on warfarin undergoing coronary stent implantation: results of the multicenter, prospective WARfarin and coronary STENTing (WAR-STENT) registry.

    PubMed

    Rubboli, Andrea; Sciahbasi, Alessandro; Briguori, Carlo; Saia, Francesco; Palmieri, Cataldo; Moroni, Luigi Andrea; Calabrò, Paolo; Leone, Antonio Maria; Franco, Nicoletta; Valgimigli, Marco; Varani, Elisabetta; Santi, Michela; Pasqualini, Paola; Capecchi, Alessandro; Piccalò, Giacomo; Margheri, Massimo; di Pasquale, Giuseppe; Galvani, Marcello; Bolognese, Leonardo; Gonzini, Lucio; Maggioni, Aldo Pietro

    2013-04-01

    The in-hospital management of patients on warfarin undergoing coronary stent implantation (PCI-S) is variable, and the in-hospital outcome incompletely defined. To determine the adherence to the current recommendations, and the incidence of adverse events, we carried out the prospective, multicenter, observational WARfarin and coronary STENTing (WAR-STENT) registry (ClinicalTrials.gov identifier NCT00722319). All consecutive patients on warfarin undergoing PCI-S at 37 Italian centers were enrolled and followed for 12 months. Outcome measures were: major adverse cardiovascular events (MACE), including cardiovascular death, non-fatal myocardial infarction, need for urgent revascularization, stroke, and venous thromboembolism, and major and minor bleeding. In this paper, we report the in-hospital findings. Out of the 411 patients enrolled, 92% were at non-low (ie, moderate or high) thromboembolic risk. The radial approach and bare-metal stents were used in 61% and 60% of cases, respectively. Drug-eluting stents were essentially reserved to patients with diabetes, which in turn, significantly predicted the implantation of drug-eluting stents (odds ratio [OR], 2.02; 95% confidence interval [CI], 1.29-3.17; P=.002). The in-hospital MACE and major bleeding rates were 2.7% and 2.1%, respectively. At discharge, triple therapy (TT) of warfarin, aspirin, and clopidogrel was prescribed to 76% of patients. Prescription of TT was significantly more frequent in the non-low thromboembolic risk group. Non-low thromboembolic risk, in turn, was a significant predictor of TT prescription (OR, 11.2; 95% CI, 4.83-26.3; P<.0001). In conclusion, real-world warfarin patients undergoing PCI-S are largely managed according to the current recommendations. As a consequence, the risk of in-hospital MACE and major bleedings appears limited and acceptable.

  3. Delivery of large biopharmaceuticals from cardiovascular stents: a review

    PubMed Central

    Takahashi, Hironobu; Letourneur, Didier; Grainger, David W.

    2008-01-01

    This review focuses on the new and emerging large-molecule bioactive agents delivered from stent surfaces in drug-eluting stents (DES) to inhibit vascular restenosis in the context of interventional cardiology. New therapeutic agents representing proteins, nucleic acids (small interfering RNAs and large DNA plasmids), viral delivery vectors and even engineered cell therapies require specific delivery designs distinct from traditional smaller molecule approaches on DES. While small molecules are currently the clinical standard for coronary stenting, extension of the DES to other lesion types, peripheral vasculature and non-vasculature therapies will seek to deliver an increasingly sophisticated armada of drug types. This review describes many of the larger molecule and biopharmaceutical approaches reported recently for stent-based delivery with the challenges associated with formulating and delivering these drug classes compared to the current small molecule drugs. It also includes perspectives on possible future applications that may improve safety and efficacy and facilitate diversification of the DES to other clinical applications. PMID:17929968

  4. The SPIRIT V study: a clinical evaluation of the XIENCE V everolimus-eluting coronary stent system in the treatment of patients with de novo coronary artery lesions.

    PubMed

    Grube, Eberhard; Chevalier, Bernard; Smits, Peter; Džavík, Vladimir; Patel, Tejas M; Mullasari, Ajit S; Wöhrle, Jochen; Stuteville, Marrianne; Dorange, Cécile; Kaul, Upendra

    2011-02-01

    The SPIRIT V (A Clinical Evaluation of the XIENCE V Everolimus-Eluting Coronary Stent System in the Treatment of Patients With De Novo Coronary Artery Lesions) study is a post-market surveillance experience of the XIENCE V (Abbott Vascular, Santa Clara, California) everolimus-eluting stent (EES) in patients with higher-risk coronary anatomy. Previous pre-approval studies have shown the safety and efficacy of EES in highly selected groups of patients. The SPIRIT V trial is a prospective, open label, single arm, multicenter study. Two thousand seven hundred patients with multiple de novo coronary artery lesions suitable for treatment with a planned maximum of 4 EES were enrolled at 93 centers in Europe, Asia Pacific, Canada, and South Africa. Lesions had a reference vessel diameter between 2.25 and 4.0 mm and a length of ≤ 28 mm by visual estimation. An independent clinical events committee adjudicated all end point-related events. The primary end point was the composite rate of all death, myocardial infarction (MI), and target vessel revascularization at 30 days. Secondary end points included stent thrombosis and acute success (clinical device and procedure success). At 30 days, the primary composite end point of all death, MI, and target vessel revascularization was 2.7%. At 1 year, rates of cardiac death, overall MI, and target lesion revascularization were 1.1%, 3.5%, and 1.8%, respectively. The cumulative rate of definite and probable stent thrombosis was low at 0.66% at 1 year. Use of EES in patients with multiple, complex de novo lesions yielded 1-year major adverse cardiac events, stent thrombosis, and target lesion revascularization rates that are comparable to those of the more controlled SPIRIT II and SPIRIT III trials-which included patients with restricted inclusion/exclusion criteria-and other all-comer population, physician-initiated studies like the X-SEARCH (Xience Stent Evaluated At Rotterdam Cardiology Hospital) and COMPARE (A Randomized

  5. Intensive oral antiplatelet therapy for reduction of ischaemic events including stent thrombosis in patients with acute coronary syndromes treated with percutaneous coronary intervention and stenting in the TRITON-TIMI 38 trial: a subanalysis of a randomised trial.

    PubMed

    Wiviott, Stephen D; Braunwald, Eugene; McCabe, Carolyn H; Horvath, Ivan; Keltai, Matyas; Herrman, Jean-Paul R; Van de Werf, Frans; Downey, William E; Scirica, Benjamin M; Murphy, Sabina A; Antman, Elliott M

    2008-04-19

    Intracoronary stenting can improve procedural success and reduce restenosis compared with balloon angioplasty in patients with acute coronary syndromes, but can also increase the rate of thrombotic complications including stent thrombosis. The TRITON-TIMI 38 trial has shown that prasugrel-a novel, potent thienopyridine-can reduce ischaemic events compared with standard clopidogrel therapy. We assessed the rate, outcomes, and prevention of ischaemic events in patients treated with prasugrel or clopidogrel with stents in the TRITON-TIMI 38 study. Patients with moderate-risk to high-risk acute coronary syndromes were included in our analysis if they had received at least one coronary stent at the time of the index procedure following randomisation in TRITON-TIMI 38, and were further subdivided by type of stent received. Patients were randomly assigned in a 1 to 1 fashion to receive a loading dose of study drug (prasugrel 60 mg or clopidogrel 300 mg) as soon as possible after randomisation, followed by daily maintenance therapy (prasugrel 10 mg or clopidogrel 75 mg). All patients were to receive aspirin therapy. Treatment was to be continued for a minimum of 6 months and a maximum of 15 months. Randomisation was not stratified by stents used or stent type. The primary endpoint was the composite of cardiovascular death, non-fatal myocardial infarction, or non-fatal stroke. Stent thrombosis was assessed using Academic Research Consortium definitions, and analysis was by intention to treat. TRITON-TIMI 38 is registered with ClinicalTrials.gov, number NCT00097591. 12,844 patients received at least one coronary stent; 5743 received only drug-eluting stents, and 6461 received only bare-metal stents. Prasugrel compared with clopidogrel reduced the primary endpoint (9.7 vs 11.9%, HR 0.81, p=0.0001) in the stented cohort, in patients with only drug-eluting stents (9.0 vs 11.1%, HR 0.82, p=0.019), and in patients with only bare-metal stents (10.0 vs 12.2%, HR 0.80, p=0

  6. Bacterial diversity of Taxus rhizosphere: culture-independent and culture-dependent approaches.

    PubMed

    Hao, Da Cheng; Ge, Guang Bo; Yang, Ling

    2008-07-01

    The regional variability of Taxus rhizosphere bacterial community composition and diversity was studied by comparative analysis of three large 16S rRNA gene clone libraries from the Taxus rhizosphere in different regions of China (subtropical and temperate regions). One hundred and forty-six clones were screened for three libraries. Phylogenetic analysis of 16S rRNA gene sequences demonstrated that the abundance of sequences affiliated with Gammaproteobacteria, Betaproteobacteria, and Actinobacteria was higher in the library from the T. xmedia rhizosphere of the temperate region compared with the subtropical Taxus mairei rhizosphere. On the other hand, Acidobacteria was more abundant in libraries from the subtropical Taxus mairei rhizosphere. Richness estimates and diversity indices of three libraries revealed major differences, indicating a higher richness in the Taxus rhizosphere bacterial communities of the subtropical region and considerable variability in the bacterial community composition within this region. By enrichment culture, a novel Actinobacteria strain DICP16 was isolated from the T. xmedia rhizosphere of the temperate region and was identified as Leifsonia shinshuensis sp. via 16S rRNA gene and gyrase B sequence analyses. DICP16 was able to remove the xylosyl group from 7-xylosyl-10-deacetylbaccatin III and 7-xylosyl-10-deacetylpaclitaxel, thereby making the xylosyltaxanes available as sources of 10-deacetylbaccatin III and the anticancer drug paclitaxel. Taken together, the present studies provide, for the first time, the knowledge of the biodiversity of microorganisms populating Taxus rhizospheres.

  7. Paclitaxel-Eluting Balloon Versus Standard Balloon Angioplasty in In-Stent Restenosis of the Superficial Femoral and Proximal Popliteal Artery: 1-Year Results of the PACUBA Trial.

    PubMed

    Kinstner, Christian M; Lammer, Johannes; Willfort-Ehringer, Andrea; Matzek, Wolfgang; Gschwandtner, Michael; Javor, Domagoj; Funovics, Martin; Schoder, Maria; Koppensteiner, Renate; Loewe, Christian; Ristl, Robin; Wolf, Florian

    2016-07-11

    The hypothesis that paclitaxel-eluting balloon angioplasty provides higher 1-year patency rates in femoropopliteal artery in-stent restenosis compared with standard percutaneous transluminal angioplasty (PTA) was tested. Several trials have demonstrated that paclitaxel-eluting balloon angioplasty reduces late luminal loss in comparison with PTA. In a prospective, randomized, single-blind, dual-center study, 74 patients with symptomatic peripheral artery disease due to in-stent restenosis were treated with either paclitaxel-based drug-eluting balloon (DEB) angioplasty (n = 35) or standard PTA (n = 39). Clinical outcomes and patency rates were assessed at 1, 6, and 12 months. The mean lesion length was 17.3 ± 11.3 cm in the DEB group and 18.4 ± 8.8 cm in the PTA group. A single major complication (bleeding) was observed once (1.4%). The mean ankle-brachial index before endovascular treatment was 0.65 ± 0.16 in both groups and 0.79 ± 0.2 versus 0.84 ± 0.3 (p = 0.70, Student t test) in the DEB versus PTA group at 12 months. The 12-month primary patency rates were 40.7% (95% confidence interval [CI]: 0.26 to 0.64) versus 13.4% (95% CI: 0.05 to 0.36) (log-rank p = 0.02) in the DEB versus PTA group. The odds ratio for PTA over DEB angioplasty for experiencing an event was estimated at 2.8 (95% CI: 1.2 to 6.6). Freedom from clinically driven target lesion revascularization was 49.0% (95% CI: 0.32 to 0.75) versus 22.1% (95% CI: 0.10 to 0.48) (log-rank p = 0.11) in the DEB versus PTA group. Clinical improvement by ≥1 Rutherford-Becker category was 68.8% versus 54.5% (p = 0.87) in the DEB versus PTA group at 12 months. When treating peripheral artery disease in patients with in-stent restenosis in the femoropopliteal artery, paclitaxel-eluting balloon angioplasty provides significantly higher patency rates than standard PTA. (Paclitaxel Balloon Versus Standard Balloon in In-Stent Restenoses of the Superficial Femoral Artery [PACUBA I Trial] [PACUBA 1]; NCT

  8. Baseline survey of root-associated microbes of Taxus chinensis (Pilger) Rehd.

    PubMed

    Zhang, Qian; Liu, Hongwei; Sun, Guiling; Wilson, Iain W; Wu, Jianqiang; Hoffman, Angela; Cheng, Junwen; Qiu, Deyou

    2015-01-01

    Taxol (paclitaxel) a diterpenoid is one of the most effective anticancer drugs identified. Biosynthesis of taxol was considered restricted to the Taxus genera until Stierle et al. discovered that an endophytic fungus isolated from Taxus brevifolia could independently synthesize taxol. Little is known about the mechanism of taxol biosynthesis in microbes, but it has been speculated that its biosynthesis may differ from plants. The microbiome from the roots of Taxus chinensis have been extensively investigated with culture-dependent methods to identify taxol synthesizing microbes, but not using culture independent methods.,Using bar-coded high-throughput sequencing in combination with a metagenomics approach, we surveyed the microbial diversity and gene composition of the root-associated microbiomefrom Taxus chinensis (Pilger) Rehd. High-throughput amplicon sequencing revealed 187 fungal OTUs which is higher than any previously reported fungal number identified with the culture-dependent method, suggesting that T. chinensis roots harbor novel and diverse fungi. Some operational taxonomic units (OTU) identified were identical to reported microbe strains possessing the ability to synthesis taxol and several genes previously associated with taxol biosynthesis were identified through metagenomics analysis.

  9. Sirolimus-eluting Biodegradable Poly-l-Lactic Acid Stent to Suppress Granulation Tissue Formation in the Rat Urethra.

    PubMed

    Kim, Kun Yung; Park, Jung-Hoon; Kim, Do Hoon; Tsauo, Jiaywei; Kim, Min Tae; Son, Woo-Chan; Kang, Sung-Gwon; Kim, Dong-Hyun; Song, Ho-Young

    2018-01-01

    Purpose To investigate the use of sirolimus-eluting biodegradable stents (SEBSs) to suppress granulation tissue formation after stent placement in a rat urethral model. Materials and Methods All experiments were approved by the animal research committee. A total of 36 male Sprague-Dawley rats were randomized into three equal groups after biodegradable stent placement. Group A received control biodegradable stents. Groups B and C received stents coated with 90 µg/cm 2 and 450 µg/cm 2 sirolimus, respectively. Six rats in each group were sacrificed after 4 weeks; the remaining rats were sacrificed after 12 weeks. The therapeutic effectiveness of SEBSs was assessed by comparing the results of retrograde urethrography and histologic examination. Analysis of variance with post hoc comparisons was used to evaluate statistical differences. Results SEBS placement was technically successful in all rats. Urethrographic and histologic examinations revealed significantly less granulation tissue formation at both time points in the rats receiving SEBSs (groups B and C) compared with those that received control stents (group A) (P < .05 for all). There were no significant differences in urethrographic and histologic findings between groups B and C (P > .05 for all). However, the mean number of epithelial layers in group B was higher than that in group C at 4 weeks after stent placement (P < .001). Apoptosis increased in group C compared with groups A and B (P < .05 for all). Conclusion The use of SEBSs suppressed granulation tissue formation secondary to stent placement in a rat urethral model; local therapy with SEBSs may be used to decrease stent-related granulation tissue formation. © RSNA, 2017.

  10. Sirolimus eluting stent (Cypher) in patients with diabetes mellitus: results from the German Cypher Stent Registry.

    PubMed

    Weber, Frank D; Schneider, Henrik; Wiemer, Marcus; Pfannebecker, Thomas; Tebbe, Ulrich; Hamm, Christian W; Senges, Jochen; Schneider, Steffen; Nienaber, Christoph A

    2008-02-01

    Patients with diabetes mellitus (DM) undergoing percutaneous coronary intervention (PCI) are at increased risk for adverse outcomes. The use of sirolimus eluting stents (SES) has been shown to improve outcomes in diabetic patients. Since results from randomized trials were derived from selected patients scientific scrutiny under real world conditions is necessary. 1,948 patients with DM and 4,707 patients without DM were included in the German Cypher Registry, a post-marketing survey of use of SES in Germany. In >99% of entry cases a structured clinical follow-up was completed. By angiographic criteria severity of coronary artery disease was higher in diabetic patients compared to non-diabetics. However, procedural success and in-hospital complication rates were comparable between DM- and non-DM-patients. 6 months MACE rate in the DM group was significantly higher than in the non-DM group (16.4% vs. 13.0%) but lower than expected from historical data with the use of bare metal stents (BMS). The results with SES in diabetics are encouraging but DM remains a risk factor for poor outcome of PCI. No statement is justified whether the treatment of diabetics with SES is at least as safe as bypass surgery. This intriguing question has to be answered in a direct randomized head-to-head comparison with state of the art surgery.

  11. Effect on Intimal Hyperplasia of Dexamethasone Released from Coated Metal Stents Compared with Non-Coated Stents in Canine Femoral Arteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strecker, Ernst-Peter; Gabelmann, Andreas; Boos, Irene

    1998-11-15

    Purpose: Polymer-coated, dexamethasone (DXM)-releasing stents were tested in order to assess the efficacy of DXM released locally for the prevention of stent restenosis due to intimal hyperplasia. Methods: Strecker stents coated with a biodegradable membrane containing DXM were implanted percutaneously into the femoral artery in 14 dogs. The contralateral artery received a conventional non-coated stent serving as control. The drugs are eluted by degradation of the carrier membrane. Follow-up intraarterial digital subtraction angiography (DSA) was obtained at 3, 6, 9, 12, and 24 weeks with subsequent autopsy. Specimens for gross and microscopic pathology were obtained and histomorphometry was performed. Results:more » Four of 14 DXM-coated stents showed thrombotic occlusion within the first 3 weeks; ten DXM-coated stents remained patent. At follow-up DSA, DXM-coated stents showed a significantly wider lumen than the non-coated stents. At morphometry there was less intimal hyperplasia over DXM-coated stents than over non-coated stents (p < 0.05). Conclusion: DXM-coated stents reduce neointimal hyperplasia in dogs when compared with non-coated stents.« less

  12. Bioresorbable Electronic Stent Integrated with Therapeutic Nanoparticles for Endovascular Diseases.

    PubMed

    Son, Donghee; Lee, Jongha; Lee, Dong Jun; Ghaffari, Roozbeh; Yun, Sumin; Kim, Seok Joo; Lee, Ji Eun; Cho, Hye Rim; Yoon, Soonho; Yang, Shixuan; Lee, Seunghyun; Qiao, Shutao; Ling, Daishun; Shin, Sanghun; Song, Jun-Kyul; Kim, Jaemin; Kim, Taeho; Lee, Hakyong; Kim, Jonghoon; Soh, Min; Lee, Nohyun; Hwang, Cheol Seong; Nam, Sangwook; Lu, Nanshu; Hyeon, Taeghwan; Choi, Seung Hong; Kim, Dae-Hyeong

    2015-06-23

    Implantable endovascular devices such as bare metal, drug eluting, and bioresorbable stents have transformed interventional care by providing continuous structural and mechanical support to many peripheral, neural, and coronary arteries affected by blockage. Although effective in achieving immediate restoration of blood flow, the long-term re-endothelialization and inflammation induced by mechanical stents are difficult to diagnose or treat. Here we present nanomaterial designs and integration strategies for the bioresorbable electronic stent with drug-infused functionalized nanoparticles to enable flow sensing, temperature monitoring, data storage, wireless power/data transmission, inflammation suppression, localized drug delivery, and hyperthermia therapy. In vivo and ex vivo animal experiments as well as in vitro cell studies demonstrate the previously unrecognized potential for bioresorbable electronic implants coupled with bioinert therapeutic nanoparticles in the endovascular system.

  13. Impact of stent strut design in metallic stents and biodegradable scaffolds.

    PubMed

    Foin, Nicolas; Lee, Renick D; Torii, Ryo; Guitierrez-Chico, Juan Luis; Mattesini, Alessio; Nijjer, Sukhjinder; Sen, Sayan; Petraco, Ricardo; Davies, Justin E; Di Mario, Carlo; Joner, Michael; Virmani, Renu; Wong, Philip

    2014-12-20

    Advances in the understanding of healing mechanisms after stent implantation have led to the recognition of stent strut thickness as an essential factor affecting re-endothelialization and overall long term vessel healing response after Percutaneous Coronary Interventions (PCI). Emergence of Drug-eluting stents (DESs) with anti-proliferative coating has contributed to reducing the incidence of restenosis and Target Lesion Revascularization (TVR), while progress and innovations in stent materials have in the meantime facilitated the design of newer platforms with more conformability and thinner struts, producing lesser injury and improving integration into the vessel wall. Recent advances in biodegradable metal and polymer materials now also allow for the design of fully biodegradable platforms, which are aimed at scaffolding the vessel only temporarily to prevent recoil and constrictive remodeling of the vessel during the initial period required, and are then progressively resorbed thereby avoiding the drawback of leaving an unnecessary implant permanently in the vessel. The aim of this article is to review recent evolution in stent material and stent strut design while understanding their impact on PCI outcomes. The article describes the different metallic alloys and biodegradable material properties and how these have impacted the evolution of stent strut thickness and ultimately outcomes in patients. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  14. First Approval of Improved Medical Device Conditional on Use-Result Survey in Japan - Regulatory Review of Polymer-Free Drug-Coated BioFreedom Coronary Stent.

    PubMed

    Konishi, Akihide; Ho, Mami; Shirai, Yuko; Shirato, Haruki

    2018-05-25

    A prospective randomized clinical trial showed that the BioFreedom stent (Biosensors International), which is a polymer-free and carrier-free drug-coated stent, was significantly superior to a bare-metal stent (BMS) in patients at high bleeding risk who were receiving a 1-month course of dual antiplatelet therapy (DAPT). However, the stent thrombosis rate (2.01% for BioFreedom vs. 2.20% for BMS) was 4-6-fold higher than that of approved drug-eluting stents based on real-world data in Japan. Furthermore, the frequency of stent thrombosis at more than 1 month with the BioFreedom stent was slightly higher than that at less than 1 month. This result suggested that it would not be acceptable to stop DAPT universally at 1 month. Thus, the target patients for the BioFreedom stent are unspecified patients at high bleeding risk needing to continue DAPT for as long as necessary in Japan. Therefore, based on the pre- and post-marketing balance of medical devices regulations, regulatory approval was given for unspecified patients conditionally upon real-world data collection of 2,000 patients with a Use-Results Survey, instead of conducting additional pre-marketing clinical trial(s). The Use-Results Survey System is part of a strategy to expedite patients' access to innovative medical devices and to accelerate the development of medical devices.

  15. Five-year clinical outcomes of everolimus-eluting stents from the post marketing study of CoCr-EES (XIENCE V/PROMUS) in Japan.

    PubMed

    Aoki, Jiro; Kozuma, Ken; Awata, Masaki; Nanasato, Mamoru; Shiode, Nobuo; Tanabe, Kengo; Yamaguchi, Junichi; Kusano, Hajime; Nie, Hong; Kimura, Takeshi

    2018-02-26

    The Cobalt Chromium Everolimus-Eluting Stent (CoCr-EES) Post Marketing Surveillance (PMS) Japan study is a prospective multicenter registry designed to evaluate the safety and efficacy of XIENCE V/PROMUS everolimus-eluting stents in routine clinical practice at 47 centers representative of the clinical environment in Japan. We enrolled 2010 consecutive patients (2649 lesions) who underwent percutaneous coronary intervention using CoCr-EES. Clinical outcomes were evaluated through 5 years. Mean age was 68.8 years, 41.9% had diabetes, 4.9% received hemodialysis. Five-year clinical follow up was available for 1704 (84.8%) patients. Major adverse cardiovascular events (MACE) occurred in 10.7% of patients, including cardiac death (3.8%), myocardial infarction (1.8%), and clinically driven target lesion revascularization (TLR) (6.0%). Beyond 1 year, annual incidence of clinically driven TLR was 0.5-0.8%. Definite or probable stent thrombosis occurred in 9 (0.5%) patients at 5 years. After 1 year, definite stent thrombosis occurred in only 1 patient. Significant predictors for MACE were dialysis (ODDs ratio 4.58, 95% CI 2.75-7.64), prior cardiac intervention (ODDs ratio 2.47, 95% CI 1.75-3.49), total stent length (ODDs ratio 1.01, 95% CI 1.01-1.02), and number of diseased vessels (ODDs ratio 1.66, 95% CI 1.08-2.55). Five-year clinical outcomes from the CoCr-EES PMS Japan study demonstrated a low incidence of clinical events in the daily practice up to 5 years. https://clinicaltrials.gov/ct2/show/NCT01086228 .

  16. Satisfactory arterial repair 1 year after ultrathin strut biodegradable polymer sirolimus-eluting stent implantation: an angioscopic observation.

    PubMed

    Ishihara, Takayuki; Awata, Masaki; Iida, Osamu; Fujita, Masashi; Masuda, Masaharu; Okamoto, Shin; Nanto, Kiyonori; Kanda, Takashi; Tsujimura, Takuya; Uematsu, Masaaki; Mano, Toshiaki

    2018-01-15

    The ultrathin strut biodegradable polymer sirolimus-eluting stent (Orsiro, O-SES) exhibits satisfactory clinical outcomes. However, no report to date has documented the intravascular status of artery repair after O-SES implantation. We examined 5 O-SES placed in 4 patients (age 65 ± 12 years, male 75%) presenting with stable angina pectoris due to de novo lesions in native coronary arteries. Coronary angioscopy was performed immediately after percutaneous coronary intervention and 1 year later. Angioscopic images were analyzed to determine the following: (1) dominant grade of neointimal coverage (NIC) over the stent; (2) maximum yellow plaque grade; and (3) existence of thrombus. Yellow plaque grade was evaluated both immediately after stent implantation and at the time of follow-up observation. The other parameters were evaluated at the time of follow-up examination. NIC was graded as: grade 0, stent struts exposed; grade 1, struts bulging into the lumen, although covered; grade 2, struts embedded in the neointima, but translucent; grade 3, struts fully embedded and invisible. Yellow plaque severity was graded as: grade 0, white; grade 1, light yellow; grade 2, yellow; and grade 3, intensive yellow. Angioscopic findings at 1 year demonstrated the following: dominant NIC grade 1, grade 2, and grade 3 in 1, 2, and 2 stents, respectively; all stents were covered to some extent; focal thrombus adhesion was observed in only 1 stent. Yellow plaque grade did not change from immediately after stent implantation to follow-up. O-SES demonstrated satisfactory arterial repair 1 year after implantation.

  17. Baseline Survey of Root-Associated Microbes of Taxus chinensis (Pilger) Rehd

    PubMed Central

    Sun, Guiling; Wilson, Iain W.; Wu, Jianqiang; Hoffman, Angela; Cheng, Junwen; Qiu, Deyou

    2015-01-01

    Taxol (paclitaxel) a diterpenoid is one of the most effective anticancer drugs identified. Biosynthesis of taxol was considered restricted to the Taxus genera until Stierle et al. discovered that an endophytic fungus isolated from Taxus brevifolia could independently synthesize taxol. Little is known about the mechanism of taxol biosynthesis in microbes, but it has been speculated that its biosynthesis may differ from plants. The microbiome from the roots of Taxus chinensis have been extensively investigated with culture-dependent methods to identify taxol synthesizing microbes, but not using culture independent methods.,Using bar-coded high-throughput sequencing in combination with a metagenomics approach, we surveyed the microbial diversity and gene composition of the root-associated microbiomefrom Taxus chinensis (Pilger) Rehd. High-throughput amplicon sequencing revealed 187 fungal OTUs which is higher than any previously reported fungal number identified with the culture-dependent method, suggesting that T. chinensis roots harbor novel and diverse fungi. Some operational taxonomic units (OTU) identified were identical to reported microbe strains possessing the ability to synthesis taxol and several genes previously associated with taxol biosynthesis were identified through metagenomics analysis. PMID:25821956

  18. [Value of the optical coherence tomography in the treatment guided of the stent failure. Case report].

    PubMed

    Macías, Enrico; Tellez, Alejandro; Ochoa, Jorge; Ortíz, José E

    2014-01-01

    Since the advent of bare metal and drug-eluting stents, the surgical revascularization have declined considerably, however the thrombosis and in-stent restenosis are important complications of these devices. There are several factors that predispose to thrombosis and in-stent restenosis. Conventional angiography has serious limitations to determine the causes of stent failure. Optical coherence tomography is a very sensitive technique to determine the cause of thrombosis and in-stent restenosis. Copyright © 2013 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  19. Gender difference on five-year outcomes of EXCEL biodegradable polymer-coated sirolimus-eluting stents implantation: results from the CREATE study.

    PubMed

    Zhang, Lei; Qiao, Bing; Han, Ya-Ling; Li, Yi; Xu, Kai; Zhang, Quan-Yu; Yang, Li-Xia; Liu, Hui-Liang; Xu, Bo; Gao, Run-Lin

    2013-03-01

    The gender difference on long-term outcome in unselected patients after percutaneous coronary intervention (PCI) has not yet been fully investigated. This study aimed to evaluate the gender difference on five-year outcomes following EXCEL biodegradable polymer-coated sirolimus-eluting stenting in patients with coronary disease. A total of 2077 "all comers", consisting of 1528 (73.6%) men and 549 (26.4%) women, who were exclusively treated with EXCEL coronary stents were enrolled in the prospective CREATE study at 59 centers from four countries. After propensity score matching, the baseline characteristics of the two groups were well matched. Recommended antiplatelet regimen was clopidogrel and aspirin for six months followed by chronic aspirin therapy. The primary outcome that was the rate of major adverse cardiac events (MACE), defined as a composite of cardiac mortality, non-fatal myocardial infarction (MI) and target lesion revascularization (TLR), and stent thrombosis (ST) at five years were compared between the two gender groups. In the two groups, women had higher proportions of clinical risk factors, such as being elderly, diabetes mellitus, hypertension and hyperlipidemia, compared to men. Besides, the mean target vessel number per patient was higher and the mean reference vessel diameter smaller for women. Men had higher risks of cardiac death (3.7% vs. 1.6%, P = 0.021) and MACE (8.4% vs. 4.7%, P = 0.004) at five years compared with women. However, the cumulative hazards of non-fatal MI and TLR were similar between men and women. The incidence of Academic Research Consortium (ARC) definite or probable stent thrombosis was similar between the two groups (1.3% vs. 1.0%, P = 0.639). Prolonged clopidogrel therapy (>6 months) did not reduce the cumulative hazards of ST from six months to five years in both men (χ(2) = 0.098, log rank P = 0.754) and women (χ(2) = 2.043, log rank P = 0.153) patients. Women had a lower MACE and cardiac death rate than men after

  20. Zilver PTX Post-Market Surveillance Study of Paclitaxel-Eluting Stents for Treating Femoropopliteal Artery Disease in Japan: 12-Month Results.

    PubMed

    Yokoi, Hiroyoshi; Ohki, Takao; Kichikawa, Kimihiko; Nakamura, Masato; Komori, Kimihiro; Nanto, Shinsuke; O'Leary, Erin E; Lottes, Aaron E; Snyder, Scott A; Dake, Michael D

    2016-02-08

    This multicenter, prospective, post-market surveillance study in Japan evaluates the paclitaxel-coated Zilver PTX stent in real-world patients with complex lesions. The Zilver PTX stent is the first drug-eluting stent (DES) approved for the superficial femoral artery. Previously, results from a large randomized study and a complementary, large single-arm study supported the safety and effectiveness of the DES. There were no exclusion criteria, and consecutive patients with symptomatic peripheral artery disease (PAD) treated with the DES were enrolled in the study. Clinically driven target lesion revascularization (TLR) was defined as reintervention performed for ≥50% diameter stenosis after recurrent clinical symptoms of PAD. Clinical benefit was defined as freedom from persistent or worsening symptoms of ischemia. Patency was evaluated by duplex ultrasound where physicians considered this standard of care. In this study, 907 patients were enrolled at 95 institutions in Japan. There were numerous comorbidities including high incidences of diabetes (58.8%), chronic kidney disease (43.8%), and critical limb ischemia (21.5%). Lesions were also complex, with an average length of 14.7 cm, 41.6% total occlusions, and 18.6% in-stent restenosis. In total, 1,861 DES were placed in 1,075 lesions. Twelve-month follow-up was obtained for >95% of eligible patients. Freedom from TLR was 91.0%, and clinical benefit was 87.7% through 12 months. The 12-month primary patency rate was 86.4%. Despite more challenging lesions, results from the current study are similar to outcomes from the previous Zilver PTX studies, confirming the benefit of the Zilver PTX DES in a real-world patient population. (Zilver PTX Post-Market Study in Japan; NCT02254837). Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  1. Expert Opinion: Optimising Stent Deployment in Contemporary Practice: The Role of Intracoronary Imaging and Non-compliant Balloons.

    PubMed

    Seth, Ashok; Gupta, Sajal; Pratap Singh, Vivudh; Kumar, Vijay

    2017-09-01

    Final stent dimensions remain an important predictor of restenosis, target vessel revascularisation (TVR) and subacute stent thrombosis (ST), even in the drug-eluting stent (DES) era. Stent balloons are usually semi-compliant and thus even high-pressure inflation may not achieve uniform or optimal stent expansion. Post-dilatation with non-compliant (NC) balloons after stent deployment has been shown to enhance stent expansion and could reduce TVR and ST. Based on supporting evidence and in the absence of large prospective randomised outcome-based trials, post-dilatation with an NC balloon to achieve optimal stent expansion and maximal luminal area is a logical technical recommendation, particularly in complex lesion subsets.

  2. Comparing mortality between coronary artery bypass grafting and percutaneous coronary intervention with drug-eluting stents in elderly with diabetes and multivessel coronary disease.

    PubMed

    Naito, Ryo; Miyauchi, Katsumi; Konishi, Hirokazu; Tsuboi, Shuta; Ogita, Manabu; Dohi, Tomotaka; Kajimoto, Kan; Kasai, Takatoshi; Tamura, Hiroshi; Okazaki, Shinya; Isoda, Kikuo; Yamamoto, Taira; Amano, Atsushi; Daida, Hiroyuki

    2016-09-01

    Coronary artery disease is a critical issue that requires physicians to consider appropriate treatment strategies, especially for elderly people who tend to have several comorbidities, including diabetes mellitus (DM) and multivessel disease (MVD). Several studies have been conducted comparing clinical outcomes between percutaneous coronary intervention (PCI) and coronary artery bypass graft (CABG) in patients with DM and MVD. However, elderly people were excluded in those clinical studies. Therefore, there are no comparisons of clinical outcomes between CABG and PCI in elderly patients with DM and MVD. We compared all-cause mortality between PCI with drug-eluting stents (DES) and CABG in elderly patients with DM and MVD. A total of 483 (PCI; n = 256, CABG; n = 227) patients were analyzed. The median follow-up period was 1356 days (interquartile range of 810-1884). The all-cause mortality rate was not significantly different between CABG and PCI with DES groups. The CABG group had more patients with complex coronary lesions such as three-vessel disease or a left main trunk lesion. Older age, hemodialysis, and reduced LVEF were associated with increased long-term all-cause mortality in a multivariable Cox regression analysis. The rate of all-cause mortality was not significantly different between the PCI and CABG groups in elderly patients with DM and MVD in a single-center study.

  3. A prospective, randomized evaluation of a novel everolimus-eluting coronary stent: the PLATINUM (a Prospective, Randomized, Multicenter Trial to Assess an Everolimus-Eluting Coronary Stent System [PROMUS Element] for the Treatment of Up to Two de Novo Coronary Artery Lesions) trial.

    PubMed

    Stone, Gregg W; Teirstein, Paul S; Meredith, Ian T; Farah, Bruno; Dubois, Christophe L; Feldman, Robert L; Dens, Joseph; Hagiwara, Nobuhisa; Allocco, Dominic J; Dawkins, Keith D

    2011-04-19

    We sought to evaluate the clinical outcomes with a novel platinum chromium everolimus-eluting stent (PtCr-EES) compared with a predicate cobalt chromium everolimus-eluting stent (CoCr-EES) in patients undergoing percutaneous coronary intervention (PCI). Randomized trials have demonstrated an excellent safety and efficacy profile for the CoCr-EES. The PtCr-EES uses the identical antiproliferative agent and polymer but with a novel platinum chromium scaffold designed for enhanced deliverability, vessel conformability, side-branch access, radiopacity, radial strength, and fracture resistance. A total of 1,530 patients undergoing PCI of 1 or 2 de novo native lesions were randomized at 132 worldwide sites to CoCr-EES (n = 762) or PtCr-EES (n = 768). The primary endpoint was the 12-month rate of target lesion failure (TLF), the composite of target vessel-related cardiac death, target vessel-related myocardial infarction (MI), or ischemia-driven target lesion revascularization (TLR) in the per-protocol population (patients who received ≥1 assigned study stent), powered for noninferiority. The 12-month rate of TLF in the per-protocol population occurred in 2.9% versus 3.4% of patients assigned to CoCr-EES versus PtCr-EES, respectively (difference: 0.5%, 95% confidence interval: -1.3% to 2.3%, p(noninferiority) = 0.001, p(superiority) = 0.60). By intention-to-treat, there were no significant differences between CoCr-EES and PtCr-EES in the 12-month rates of TLF (3.2% vs. 3.5%, p = 0.72), cardiac death or MI (2.5% vs. 2.0%, p = 0.56), TLR (1.9% vs. 1.9%, p = 0.96), or Academic Research Consortium definite or probable stent thrombosis (0.4% vs. 0.4%, p = 1.00). In this large-scale, prospective, single-blind randomized trial, a novel PtCr-EES was noninferior to the predicate CoCr-EES for TLF, with nonsignificant differences in measures of safety and efficacy through 12-month follow-up after PCI. Copyright © 2011 American College of Cardiology Foundation. Published by

  4. Differential impact of five coronary devices on plaque size: insights from the ABSORB and SPIRIT trials.

    PubMed

    García-García, Héctor M; Serruys, Patrick W; Campos, Carlos M; Onuma, Yoshinobu

    2014-08-20

    Coronary plaque size modification, by either local (device) or systemic treatments, has been the target for many years. From ABSORB Cohort A (Absorb BVS 1.0), ABSORB Cohort B (Absorb BVS 1.1), SPIRIT FIRST (Multi-Link Vision vs. Xience V) & SPIRIT II (Xience V vs. Taxus), we calculated the total plaque area (vessel minus lumen area - thus it comprises both compartments - the plaque behind struts and the neointima.) changes by IVUS. A total of 313 patients were included. Comparison-at-6-month follow-up: All devices induced an increase in the total plaque area. The largest increase occurred with Vision and Taxus stents as compared to other devices [Absorb BVS (1.0 and 1.1) and Xience V], (p=0.0002). Comparison-at-2-year follow-up: Absorb BVS 1.1 had a larger increase from post procedure in total plaque compared to Absorb BVS 1.0, Xience V and Taxus (p=0.0499). However, in Absorb BVS 1.1 total plaque showed a reduction of 2.2% from 1 to 3 years. Specifically, the total plaque in the sequential cohorts of Absorb BVS 1.1 increased 16.2% from baseline to 2 years (Cohort B1) while at 3 years this increase is only 5% compared to baseline (Cohort B2). Local devices affect coronary plaque size differently and it depends on the platform (metallic vs. polymeric) and on whether it is a bare - or drug eluting stent. Coronary scaffolds appear to be a promising alternative to metallic stents since they allow plaque regression at long-term follow-up. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  5. Dynamic simulation of stent deployment - effects of design, material and coating

    NASA Astrophysics Data System (ADS)

    Schiavone, A.; Zhao, L. G.; Abdel-Wahab, A. A.

    2013-07-01

    Dynamic finite-element simulations have been carried out to study the effects of cell design, material choice and drug eluting coating on the mechanical behaviour of stents during deployment. Four representative stent designs have been considered, i.e., Palmaz-Schatz, Cypher, Xience and Endeavor. The former two are made of stainless steel while the latter two made of Co-Cr alloy. Geometric model for each design was created using ProEngineer software, and then imported into Abaqus for simulation of the full process of stent deployment within a diseased artery. In all cases, the delivery system was based on the dynamic expansion of a polyurethane balloon under applied internal pressure. Results showed that the expansion is mainly governed by the design, in particular open-cell design (e.g. Endeavor) tends to have greater expansion than closed-cell design (e.g. Cypher). Dogboning effect was strong for slotted tube design (e.g. Palmaz-Schatz) but reduced significantly for sinusoidal design (e.g. Cypher). Under the same pressure, the maximum von Mises stress in the stent was higher for the open-cell designs and located mostly at the inner corners of each cell. For given deformation, stents made of Co-Cr alloys tend to experience higher stress level than those made of stainless steels, mainly due to the difference in material properties. For artery-plaque system, the maximum stress occurred on the stenosis and dogboning led to stress concentration at the ends of the plaque. The drug eluting coating affected the stent expansion by reducing the recoiling phenomenon considerably, but also raised the stress level on the stent due to property mismatch.

  6. Long-Term Outcomes of Stenting the Proximal Left Anterior Descending Artery in the PROTECT Trial.

    PubMed

    Roguin, Ariel; Camenzind, Edoardo; Kerner, Arthur; Beyar, Rafael; Boersma, Eric; Mauri, Laura; Steg, Ph Gabriel; Wijns, William

    2017-03-27

    This study sought to compare the outcomes of patients undergoing drug-eluting stent implantation according to lesion location within or outside the proximal left anterior descending (LAD) artery. Proximal LAD artery involvement is considered uniquely in revascularization guidelines. The impact of LAD lesion location on long-term outcomes after revascularization is poorly understood in context of current percutaneous coronary intervention and medical therapy. Among 8,709 patients enrolled in PROTECT (Patient Related Outcomes with Endeavor Versus Cypher Stenting Trial), a multicenter percutaneous coronary intervention trial, we compared the outcomes of 2,534 patients (29.1%) (3,871 lesions [31.5%]) with stents implanted in the proximal LAD to 6,172 patients (70.9%) (8,419 lesions [68.5%]) with stents implanted outside the proximal LAD. At the 4-year follow-up, death rates were the same (5.8% vs. 5.8%; p > 0.999), but more myocardial infarctions occurred in the proximal LAD group (6.2% vs. 4.9%; p = 0.015). The rate of clinically driven target vessel failure (TVF) (14.8% vs. 13.5%; p = 0.109), major adverse cardiac event(s) (MACE) (15.0% vs. 13.7%; hazard ratio: 1.1; 95% confidence interval: 0.97 to 1.31; p = 0.139), and stent thrombosis (2.1% vs. 2.0%; p = 0.800) were similar. Drug-eluting stent type had no interaction with MACE or TVF. In multivariate analysis, the proximal LAD was a predictor of myocardial infarction (p = 0.038) but not of TVF (p = 0.149) or MACE (p = 0.069). In this study of contemporary percutaneous coronary intervention, proximal LAD location was associated with higher rates of myocardial infarction during the long-term follow-up, but there were no differences in stent thrombosis, death, TVF, or overall MACE. This finding may suggest that, in the drug-eluting stent era, proximal LAD no longer confers a different prognosis than other lesion sites. (Randomized Study Comparing Endeavor With Cypher Stents [PROTECT]; NCT00476957

  7. In-situ investigation of stress conditions during expansion of bare metal stents and PLLA-coated stents using the XRD sin(2)ψ-technique.

    PubMed

    Kowalski, Wolfgang; Dammer, Markus; Bakczewitz, Frank; Schmitz, Klaus-Peter; Grabow, Niels; Kessler, Olaf

    2015-09-01

    Drug eluting stents (DES) consist of platform, coating and drug. The platform often is a balloon-expandable bare metal stent made of the CoCr alloy L-605 or stainless steel 316 L. The function of the coating, typically a permanent polymer, is to hold and release the drug, which should improve therapeutic outcome. Before implantation, DES are compressed (crimped) to allow implantation in the human body. During implantation, DES are expanded by balloon inflation. Crimping, as well as expansion, causes high stresses and high strains locally in the DES struts, as well as in the polymer coating. These stresses and strains are important design criteria of DES. Usually, they are calculated numerically by finite element analysis (FEA), but experimental results for validation are hardly available. In this work, the X-ray diffraction (XRD) sin(2)ψ-technique is applied to in-situ determination of stress conditions of bare metal L-605 stents, and Poly-(L-lactide) (PLLA) coated stents. This provides a realistic characterization of the near-surface stress state and a validation option of the numerical FEA. XRD-results from terminal stent struts of the bare metal stent show an increasing compressive load stress in tangential direction with increasing stent expansion. These findings correlate with numerical FEA results. The PLLA-coating also bears increasing compressive load stress during expansion. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Cost effectiveness of drug-eluting stents in acute myocardial infarction patients in Germany: results from administrative data using a propensity score-matching approach.

    PubMed

    Bäumler, Michael; Stargardt, Tom; Schreyögg, Jonas; Busse, Reinhard

    2012-07-01

    The high number of patients with acute myocardial infarction (AMI) has facilitated greater research, resulting in the development of innovative medical devices. So far, results from economic evaluations that compared drug-eluting stents (DES) and bare-metal stents (BMS) have not shown clear evidence that one intervention is more cost effective than the other. The aim of this study was to measure the cost effectiveness of DES compared with BMS in routine care. We used administrative data from a large German sickness fund to compare the costs and effectiveness of DES and BMS in patients with AMI. Patients with hospital admission after AMI in 2004 and 2005 were followed up for 1 year after hospital discharge. The cost of treatment and survival after 365 days were compared for patients treated with DES and BMS. We adjusted for covariates defined according to the Ontario Acute Myocardial Infarction Mortality Prediction Rules using propensity score matching. After matching, we calculated incremental cost-effectiveness ratios (ICERs) by (i) using sample means based on bootstrapping procedures and (ii) estimating generalized linear mixed models for costs and survival. After propensity score matching, the sample included 719 patients treated with DES and 719 patients treated with BMS. A comparison of sample means resulted in average costs of € 12 714 and € 11 714 for DES and BMS, respectively, in 2005 German euros. Difference in 365-day survival was not statistically significant (700 patients with DES and 701 with BMS). The ICER of DES versus BMS was -€ 718 709 per life saved. Bootstrapping resulted in DES being dominated by BMS in 54.5% of replications and DES being a dominant strategy in 2.7% of replications. Results from regression models and sensitivity analyses confirm these results. Treatment with DES after admission with AMI is less cost effective than treatment with BMS. Our results are in line with other cost-effectiveness analyses that used administrative

  9. Efficacy and safety of a biodegradable polymer sirolimus-eluting stent in primary percutaneous coronary intervention: a randomized controlled trial

    PubMed Central

    Li, Qiang; Tong, Zichuan; Wang, Lefeng; Zhang, Jianjun; Ge, Yonggui; Wang, Hongshi; Li, Weiming; Xu, Li; Ni, Zhuhua

    2013-01-01

    Introduction With long-term follow-up, whether biodegradable polymer drug-eluting stents (DES) is efficient and safe in primary percutaneous coronary intervention (PCI) remains a controversial issue. This study aims to assess the long-term efficacy and safety of DES in PCI for ST-segment elevation myocardial infarction (STEMI). Material and methods A prospective, randomized single-blind study with 3-year follow-up was performed to compare biodegradable polymer DES with durable polymer DES in 332 STEMI patients treated with primary PCI. The primary end point was major adverse cardiac events (MACE) at 3 years after the procedure, defined as the composite of cardiac death, recurrent infarction, and target vessel revascularization. The secondary end points included in-segment late luminal loss (LLL) and binary restenosis at 9 months and cumulative stent thrombosis (ST) event rates up to 3 years. Results The rate of the primary end points and the secondary end points including major adverse cardiac events, in-segment late luminal loss, binary restenosis, and cumulative thrombotic event rates were comparable between biodegradable polymer DES and durable polymer DES in these 332 STEMI patients treated with primary PCI at 3 years. Conclusions Biodegradable polymer DES has similar efficacy and safety profiles at 3 years compared with durable polymer DES in STEMI patients treated with primary PCI. PMID:24482648

  10. A clinical evaluation of the ProNOVA XR polymer-free sirolimus eluting coronary stent system in the treatment of patients with de novo coronary artery lesions (EURONOVA XR I study)☆

    PubMed Central

    Legutko, Jacek; Zasada, Wojciech; Kałuża, Grzegorz L.; Heba, Grzegorz; Rzeszutko, Lukasz; Jakala, Jacek; Dragan, Jacek; Klecha, Artur; Giszterowicz, Dawid; Dobrowolski, Wojciech; Partyka, Łukasz; Jayaraman, Swaminathan; Dudek, Dariusz

    2013-01-01

    Aims Evaluation of safety and efficacy of ProNOVA XR, a new generation of polymer-free sirolimus eluting stents (SES), utilizing a pharmaceutical excipient for timed release of sirolimus from the XR platform. Methods and results Safety and efficacy of ProNOVA XR coronary stent system was examined in EURONOVA prospective, single arm, multi-center registry of 50 patients with de novo native coronary lesions up to 28 mm in length in arteries between 2.25 and 4 mm. At 6-month, in-stent late lumen loss by QCA was 0.45 ± 0.41 mm and in-stent neointimal volume obstruction in the IVUS sub-study was 14 ± 11%. One-year clinical follow-up revealed a favorable safety profile, with 2% of in-hospital MACE and 6.4% of MACE from hospital discharge up to 12 months (including 1 cardiac death >30 days after stent implantation and 2 TLRs). According to the ARC definition, there was no definite or probable stent thrombosis and 1 possible stent thrombosis (2%) up to 12 months of clinical follow-up. Conclusions In this preliminary evaluation, ProNOVA XR polymer-free sirolimus eluting stent system appeared safe with an early promise of adequate effectiveness in the treatment of de novo coronary lesions in up to 12 months of clinical, angiographic and IVUS follow-up. PMID:23992999

  11. Sirolimus versus paclitaxel coronary stents in clinical practice.

    PubMed

    Millauer, Niklas; Jüni, Peter; Hofmann, Alexandra; Wandel, Simon; Bhambhani, Anupham; Billinger, Michael; Urwyler, Niklaus; Wenaweser, Peter; Hellige, Gerrit; Räber, Lorenz; Cook, Stéphane; Vogel, Rolf; Togni, Mario; Seiler, Christian; Meier, Bernhard; Windecker, Stephan

    2011-01-01

    We aimed at comparing the long term clinical outcome of SES and PES in routine clinical practice. Although sirolimus-eluting stents (SES) more effectively reduce neointimal hyperplasia than paclitaxel-eluting stents (PES), uncertainty prevails whether this difference translates into differences in clinical outcomes outside randomized controlled trials with selected patient populations and protocol-mandated angiographic follow-up. Nine hundred and four consecutive patients who underwent implantation of a drug-eluting stent between May 2004 and February 2005: 467 patients with 646 lesions received SES, 437 patients with 600 lesions received PES. Clinical follow-up was obtained at 2 years without intervening routine angiographic follow-up. The primary endpoint was a composite of death, myocardial infarction (MI), or target vessel revascularization (TVR). At 2 years, the primary endpoint was less frequent with SES (12.9%) than PES (17.6%, HR = 0.70, 95% CI 0.50-0.98, P = 0.04). The difference in favor of SES was largely driven by a lower rate of target lesion revascularisation (TLR; 4.1% vs. 6.9%, P = 0.05), whereas rates of death (6.4% vs. 7.6%, P = 0.49), MI (1.9% vs. 3.2%, P = 0.21), or definite stent thrombosis (0.6% vs. 1.4%, P = 0.27) were similar for both stent types. The benefit regarding reduced rates of TLR was significant in nondiabetic (3.6% vs. 7.1%, P = 0.04) but not in diabetic patients (5.6% vs. 6.1%, P = 0.80). SES more effectively reduced the need for repeat revascularization procedures than PES when used in routine clinical practice. The beneficial effect is maintained up to 2 years and may be less pronounced in diabetic patients. Copyright © 2010 Wiley-Liss, Inc.

  12. Novel biliary self-expanding metal stents: indications and applications.

    PubMed

    Blero, Daniel; Huberty, Vincent; Devière, Jacques

    2015-03-01

    Endoscopic insertion of a self-expanding metal stent (SEMS) through a malignant common bile duct stricture is the first line of palliation for malignant jaundice. Patency of these stents remains a major concern. SEMS dysfunction can result from tumor ingrowth, overgrowth and/or clogging. Initial SEMS modifications involved covering the central part of the stent in order to reduce ingrowth and ultimately increase patency. Fully covered stents became available shortly after reports of their use in human patients. The potential removability and radial strength of SEMS have led to evaluation of their use in new indications including benign biliary strictures, post sphincterotomy bleeding and perforation. Other aspects of development include the addition of features such as anti-reflux valves, drug elution and spontaneous biodegradability. These aspects and their clinical implications are reviewed and discussed.

  13. Drug-Eluting Fibers for HIV-1 Inhibition and Contraception

    PubMed Central

    Ball, Cameron; Krogstad, Emily; Chaowanachan, Thanyanan; Woodrow, Kim A.

    2012-01-01

    Multipurpose prevention technologies (MPTs) that simultaneously prevent sexually transmitted infections (STIs) and unintended pregnancy are a global health priority. Combining chemical and physical barriers offers the greatest potential to design effective MPTs, but integrating both functional modalities into a single device has been challenging. Here we show that drug-eluting fiber meshes designed for topical drug delivery can function as a combination chemical and physical barrier MPT. Using FDA-approved polymers, we fabricated nanofiber meshes with tunable fiber size and controlled degradation kinetics that facilitate simultaneous release of multiple agents against HIV-1, HSV-2, and sperm. We observed that drug-loaded meshes inhibited HIV-1 infection in vitro and physically obstructed sperm penetration. Furthermore, we report on a previously unknown activity of glycerol monolaurate (GML) to potently inhibit sperm motility and viability. The application of drug-eluting nanofibers for HIV-1 prevention and sperm inhibition may serve as an innovative platform technology for drug delivery to the lower female reproductive tract. PMID:23209601

  14. [Myocardial ischemia in general medicine and the revolution of coronary stents].

    PubMed

    El-Mourad, M; Merveille, P; Preumont, N

    2014-09-01

    Since Gruentizg's first percutaneous transluminal ballon angioplasty in 1977 in Zurich, percuta. neous coronary intervention evolved significantly in order to overcome the numerous associated complications of each technique. Bare-metal stents (BMS) made their initial appearance followed by three generations of drug-eluting stents (DES). The use of bioabsorbable vascular scaffold stents (BVS) has become more frequent creating a temporary scaffold allowing healing of the endothelium within 2 years. In this article, we discuss the nomenclature of the main intravascular complications linked to percuta. neous coronary intervention such as stent thrombosis (ST), Instent restenosis (ISR), neoatherosclerosis, and stents evolution to overcome these complications. We will finally mention the new technologies of intracoronary imaging such as OCT (Optical Coherence Tomography) having an increasing vital role in percutaneous coronary intervention,

  15. Cost-effectiveness analysis of 30-month vs 12-month dual antiplatelet therapy with clopidogrel and aspirin after drug-eluting stents in patients with acute coronary syndrome.

    PubMed

    Jiang, Minghuan; You, Joyce H S

    2017-10-01

    Continuation of dual antiplatelet therapy (DAPT) beyond 1 year reduces late stent thrombosis and ischemic events after drug-eluting stents (DES) but increases risk of bleeding. We hypothesized that extending DAPT from 12 months to 30 months in patients with acute coronary syndrome (ACS) after DES is cost-effective. A lifelong decision-analytic model was designed to simulate 2 antiplatelet strategies in event-free ACS patients who had completed 12-month DAPT after DES: aspirin monotherapy (75-162 mg daily) and continuation of DAPT (clopidogrel 75 mg daily plus aspirin 75-162 mg daily) for 18 months. Clinical event rates, direct medical costs, and quality-adjusted life-years (QALYs) gained were the primary outcomes from the US healthcare provider perspective. Base-case results showed DAPT continuation gained higher QALYs (8.1769 vs 8.1582 QALYs) at lower cost (USD42 982 vs USD44 063). One-way sensitivity analysis found that base-case QALYs were sensitive to odds ratio (OR) of cardiovascular death with DAPT continuation and base-case cost was sensitive to OR of nonfatal stroke with DAPT continuation. DAPT continuation remained cost-effective when the ORs of nonfatal stroke and cardiovascular death were below 1.241 and 1.188, respectively. In probabilistic sensitivity analysis, DAPT continuation was the preferred strategy in 74.75% of 10 000 Monte Carlo simulations at willingness-to-pay threshold of 50 000 USD/QALYs. Continuation of DAPT appears to be cost-effective in ACS patients who were event-free for 12-month DAPT after DES. The cost-effectiveness of DAPT for 30 months was highly subject to the OR of nonfatal stroke and OR of death with DAPT continuation. © 2017 Wiley Periodicals, Inc.

  16. Two-year safety and effectiveness of sirolimus-eluting stents (from a prospective registry).

    PubMed

    Claessen, Bimmer E; Mehran, Roxana; Leon, Martin B; Heller, Eric A; Weisz, Giora; Syros, George; Mintz, Gary S; Franklin-Bond, Theresa; Apostolidou, Irene; Henriques, Jose P S; Stone, Gregg W; Moses, Jeffrey W; Dangas, George D

    2011-02-15

    Uncertainty exists about the long-term safety and efficacy outcomes of sirolimus-eluting stents (SESs) in unselected patients. The present study was performed to evaluate the safety and efficacy of the SES in treatment of patients with coronary artery disease in an unselected population. Over a 2-year period, 1,504 consecutive patients undergoing percutaneous coronary intervention with ≥1 SES were enrolled. The primary end point was the occurrence of target vessel failure (TVF; a composite of cardiac death, myocardial infarction, or clinically driven target vessel revascularization). An independent clinical event committee adjudicated all adverse events up to 2-year follow-up. Dual antiplatelet therapy was recommended for ≥1 year throughout the study period. Mean age was 65 ± 11 years; 75% were men, and 34% were diabetics. SESs were implanted for off-label indications in 86% of cases. TVF rates were 3.3%, 6.9%, 11.5%, and 15.5% at 30-day, 6-month, 1-year, and 2-year follow-ups, respectively. The 2-year cumulative rate of definite/probable stent thrombosis was 0.9%; 0.2% was very late thrombosis, occurring from 1 year to 2 years. Patients off dual antiplatelet therapy at 6 months had a significantly increased rate of subsequent death from noncardiac causes. Patients off dual antiplatelet therapy at 1 year had a significantly decreased rate of subsequent clinically driven target lesion revascularization. In conclusion, use of SESs in unselected patients with coronary artery disease was associated with a low TVF rate at 2 years with an acceptable incidence of stent thrombosis. Copyright © 2011 Elsevier Inc. All rights reserved.

  17. Reduced duration of dual antiplatelet therapy using an improved drug-eluting stent for percutaneous coronary intervention of the left main artery in a real-world, all-comer population: Rationale and study design of the prospective randomized multicenter IDEAL-LM trial.

    PubMed

    Lemmert, Miguel E; Oldroyd, Keith; Barragan, Paul; Lesiak, Maciej; Byrne, Robert A; Merkulov, Evgeny; Daemen, Joost; Onuma, Yoshinobu; Witberg, Karen; van Geuns, Robert-Jan

    2017-05-01

    Continuous improvements in stent technology make percutaneous coronary intervention (PCI) a potential alternative to surgery in selected patients with unprotected left main coronary artery (uLMCA) disease. The optimal duration of dual antiplatelet therapy (DAPT) in these patients remains undetermined, and in addition, new stent designs using a bioabsorbable polymer might allow shorter duration of DAPT. IDEAL-LM is a prospective, randomized, multicenter study that will enroll 818 patients undergoing uLMCA PCI. Patients will be randomized in a 1:1 fashion to intravascular ultrasound-guided PCI with the novel everolimus-eluting platinum-chromium Synergy stent with a biodegradable polymer (Boston Scientific, Natick, MA) followed by 4 months of DAPT or the everolimus-eluting cobalt-chromium Xience stent (Abbott Vascular, Santa Clara, CA) followed by 12 months of DAPT. The total follow-up period will be 5 years. A subset of 100 patients will undergo optical coherence tomography at 3 months. The primary end point will be major adverse cardiovascular events (composite of all-cause mortality, myocardial infarction, and ischemia-driven target vessel revascularization) at 2 years. Secondary end points will consist of the individual components of the primary end point, procedural success, a device-oriented composite end point, stent thrombosis as per Academic Research Consortium criteria, and bleeding as per Bleeding Academic Research Consortium criteria. IDEAL-LM is designed to assess the safety and efficacy of the novel Synergy stent followed by 4 months of DAPT vs the Xience stent followed by 12 months of DAPT in patients undergoing uLMCA PCI. The study will provide novel insights regarding optimal treatment strategy for patients undergoing PCI of uLMCA disease (www.clinicaltrials.gov, NCT 02303717). Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  18. Impact of Fluoropolymer-Based Paclitaxel Delivery on Neointimal Proliferation and Vascular Healing: A Comparative Peripheral Drug-Eluting Stent Study in the Familial Hypercholesterolemic Swine Model of Femoral Restenosis.

    PubMed

    Gasior, Pawel; Cheng, Yanping; Valencia, Andres F; McGregor, Jenn; Conditt, Gerard B; Kaluza, Grzegorz L; Granada, Juan F

    2017-05-01

    A polymer-free peripheral paclitaxel-eluting stent (PES, Zilver PTX, Cook, IN) has shown to improve vessel patency after superficial femoral angioplasty. A new-generation fluoropolymer-based PES (FP-PES; Eluvia, Boston Scientific, MA) displaying more controlled and sustained paclitaxel delivery promise to improve the clinical outcomes of first-generation PES. We sought to compare the biological effect of paclitaxel delivered by 2 different stent-coating technologies (fluoropolymer-based versus polymer-free) on neointimal proliferation and healing response in the familial hypercholesterolemic swine model of femoral restenosis. The biological efficacy of clinically available FP-PES (n=12) and PES (n=12) was compared against a bare metal stent control (n=12; Innova, Boston Scientific, MA) after implantation in the femoral arteries of 18 familial hypercholesterolemic swine. Longitudinal quantitative vascular angiography and optical coherence tomography were performed at baseline and at 30 and 90 days. Histological evaluation was performed at 90 days. Ninety-day quantitative vascular angiography results showed a lower percent diameter stenosis for FP-PES (38.78% [31.27-47.66]) compared with PES (54.16% [42.60-61.97]) and bare metal stent (74.52% [47.23-100.00]; P <0.001). Ninety-day optical coherence tomography results demonstrated significantly lower neointimal area in FP-PES (8.01 mm 2 [7.65-9.21]) compared with PES (10.95 mm 2 [9.64-12.46]) and bare metal stent (13.83 mm 2 [11.53-17.03]; P <0.001). Histological evaluation showed larger lumen areas and evidence of higher biological activity (smooth muscle cell loss and fibrin deposition) in the FP-PES compared with PES and bare metal stent. In the familial hypercholesterolemic swine model of femoral restenosis, the implantation of an FP-PES resulted in lower levels of neointimal proliferation and sustained biological effect ≤90 days compared with a polymer-free stent-based approach. © 2017 American Heart

  19. Echocardiographic identification of ventricular septal rupture caused by acute stent thrombosis.

    PubMed

    Garg, Scot; Bourantas, Christos V; Thackray, Simon; Alamgir, Mohamed F

    2010-05-01

    Coronary stenting is an increasingly common procedure. Complications are rare. However, when they do occur, they often require urgent invasive treatment. Investigations that are critical for establishing a diagnosis as well as such guide treatment as a detailed assessment of myocardial morphology and function using transthoracic echocardiography may be overlooked in the haste to treat the patient. We present a case report of subacute drug-eluting stent thrombosis in which a meticulous echocardiographic examination allowed the identification of a ventricular septal rupture, which ultimately modified treatment.

  20. Suppression of scarring in peripheral nerve implants by drug elution.

    PubMed

    FitzGerald, James J

    2016-04-01

    Medical implants made of non-biological materials provoke a chronic inflammatory response, resulting in the deposition of a collagenous scar tissue (ST) layer on their surface, that gradually thickens over time. This is a critical problem for neural interfaces. Scar build-up on electrodes results in a progressive decline in signal level because the scar tissue gradually separates axons away from the recording contacts. In regenerative sieves and microchannel electrodes, progressive scar deposition will constrict and may eventually choke off the sieve hole or channel lumen. Interface designs need to address this issue if they are to be fit for long term use. This study examines a novel method of inhibiting the formation and thickening of the fibrous scar. Research to date has mainly focused on methods of preventing stimulation of the foreign body response by implant surface modification. In this paper a pharmacological approach using drug elution to suppress chronic inflammation is introduced. Microchannel implants made of silicone doped with the steroid drug dexamethasone were implanted in the rat sciatic nerve for periods of up to a year. Tissue from within the microchannels was compared to that from control devices that did not release any drug. In the drug eluting implants the scar layer was significantly thinner at all timepoints, and unlike the controls it did not continue to thicken after 6 months. Control implants supported axon regeneration well initially, but axon counts fell rapidly at later timepoints as scar thickened. Axon counts in drug eluting devices were initially much lower, but increased rather than declined and by one year were significantly higher than in controls. Drug elution offers a potential long term solution to the problem of performance degradation due to scarring around neural implants.

  1. Suppression of scarring in peripheral nerve implants by drug elution

    NASA Astrophysics Data System (ADS)

    FitzGerald, James J.

    2016-04-01

    Objective. Medical implants made of non-biological materials provoke a chronic inflammatory response, resulting in the deposition of a collagenous scar tissue (ST) layer on their surface, that gradually thickens over time. This is a critical problem for neural interfaces. Scar build-up on electrodes results in a progressive decline in signal level because the scar tissue gradually separates axons away from the recording contacts. In regenerative sieves and microchannel electrodes, progressive scar deposition will constrict and may eventually choke off the sieve hole or channel lumen. Interface designs need to address this issue if they are to be fit for long term use. This study examines a novel method of inhibiting the formation and thickening of the fibrous scar. Approach. Research to date has mainly focused on methods of preventing stimulation of the foreign body response by implant surface modification. In this paper a pharmacological approach using drug elution to suppress chronic inflammation is introduced. Microchannel implants made of silicone doped with the steroid drug dexamethasone were implanted in the rat sciatic nerve for periods of up to a year. Tissue from within the microchannels was compared to that from control devices that did not release any drug. Main results. In the drug eluting implants the scar layer was significantly thinner at all timepoints, and unlike the controls it did not continue to thicken after 6 months. Control implants supported axon regeneration well initially, but axon counts fell rapidly at later timepoints as scar thickened. Axon counts in drug eluting devices were initially much lower, but increased rather than declined and by one year were significantly higher than in controls. Significance. Drug elution offers a potential long term solution to the problem of performance degradation due to scarring around neural implants.

  2. Incidence and Predictors of reCurrent Restenosis After Drug-coated Balloon Angioplasty for Restenosis of a drUg-eluting Stent: The ICARUS Cooperation.

    PubMed

    Cassese, Salvatore; Xu, Bo; Habara, Seiji; Rittger, Harald; Byrne, Robert A; Waliszewski, Matthias; Pérez-Vizcayno, María José; Gao, Runlin; Kastrati, Adnan; Alfonso, Fernando

    2017-09-12

    The incidence and predictors of recurrent restenosis after drug-coated balloon (DCB) angioplasty for drug-eluting stent (DES) restenosis remain poorly studied. We sought to evaluate the incidence and predictors of recurrent restenosis among participants in randomized controlled trials receiving DCB angioplasty for DES restenosis. The clinical and lesion data of individuals enrolled in 6 randomized controlled trials of DCB angioplasty for DES restenosis were pooled. All patients included in this report were assigned to receive paclitaxel-coated balloon angioplasty with the SeQuent Please DCB (B Braun, Melsungen, Germany). The current analysis focused on participants with available follow-up angiography at 6 to 9 months. The incidence of recurrent restenosis, defined as diameter restenosis ≥ 50% in the in-segment area at follow-up angiography, and its clinical and angiographic predictors were evaluated. A total of 546 patients were combined in a single dataset. Angiographic follow-up at 6 to 9 months was available for 484 patients (88.6%) with 518 treated lesions. Recurrent restenosis was detected in 101 (20.8%) patients. On multivariable analysis, lesion length (OR, 1.58; 95%CI, 1.10-2.26; P=.012 for 5mm increase) and vessel size (OR, 1.42; 95%, 1.12-1.79; P=.003 for 0.5mm reduction) were independently associated with recurrent restenosis. In the largest cohort to date of individuals with angiographic surveillance after DCB angioplasty for DES restenosis, we demonstrated that recurrent restenosis occurs in approximately 1 out of 5 patients. Predictors of recurrent restenosis are increased lesion length and small vessel size. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  3. A new scoring system (DAIGA) for predicting bleeding complications in atrial fibrillation patients after drug-eluting stent implantation with triple antithrombotic therapy.

    PubMed

    Kobayashi, Norihiro; Yamawaki, Masahiro; Nakano, Masatsugu; Hirano, Keisuke; Araki, Motoharu; Takimura, Hideyuki; Sakamoto, Yasunari; Mori, Shinsuke; Tsutsumi, Masakazu; Ito, Yoshiaki

    2016-11-15

    No scoring system for evaluating the bleeding risk of atrial fibrillation (AF) patients after drug-eluting stent (DES) implantation with triple antithrombotic therapy (TAT) is available. We aimed to develop a new scoring system for predicting bleeding complications in AF patients after DES implantation with TAT. Between April 2007 and April 2014, 227 AF patients undergoing DES implantation with TAT were enrolled. Bleeding incidence defined as Bleeding Academic Research Consortium criteria≥2 was investigated and predictors of bleeding complications were evaluated using multivariate analysis. Bleeding complications occurred in 58 patients (25.6%) during follow-up. Multivariate analysis revealed dual antiplatelet therapy (DAPT) continuation (OR 3.33, P=0.01), age>75 (OR 2.14, P=0.037), international normalized ratio>2.2 (OR 5.82, P<0.001), gastrointestinal ulcer history (OR 3.06, P=0.037), and anemia (OR 2.15, P=0.042) as predictors of major bleeding complications. A score was created using the weighted points proportional to the beta regression coefficient of each variable. The DAIGA score showed better predictive ability for bleeding complications than the HAS-BLED score (AUC: 0.79 vs. 0.62, P=0.0003). Bleeding incidence was well stratified: 17.8% in low-risk (scores 0-1), 55.5% in moderate-risk (2-3), and 83.0% in high-risk (4-7) patients (P<0.001). This scoring system is useful for predicting bleeding complications and risk stratification of AF patients after DES implantation with TAT. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  4. Prevention of premature discontinuation of dual antiplatelet therapy in patients with coronary artery stents: a science advisory from the American Heart Association, American College of Cardiology, Society for Cardiovascular Angiography and Interventions, American College of Surgeons, and American Dental Association, with representation from the American College of Physicians.

    PubMed

    Grines, Cindy L; Bonow, Robert O; Casey, Donald E; Gardner, Timothy J; Lockhart, Peter B; Moliterno, David J; O'Gara, Patrick; Whitlow, Patrick

    2007-02-13

    Dual antiplatelet therapy with aspirin and a thienopyridine has been shown to reduce cardiac events after coronary stenting. However, many patients and healthcare providers prematurely discontinue dual antiplatelet therapy, which greatly increases the risk of stent thrombosis, myocardial infarction, and death. This advisory stresses the importance of 12 months of dual antiplatelet therapy after placement of a drug-eluting stent and educating the patient and healthcare providers about hazards of premature discontinuation. It also recommends postponing elective surgery for 1 year, and if surgery cannot be deferred, considering the continuation of aspirin during the perioperative period in high-risk patients with drug-eluting stents.

  5. Prevention of premature discontinuation of dual antiplatelet therapy in patients with coronary artery stents: a science advisory from the American Heart Association, American College of Cardiology, Society for Cardiovascular Angiography and Interventions, American College of Surgeons, and American Dental Association, with representation from the American College of Physicians.

    PubMed

    Grines, Cindy L; Bonow, Robert O; Casey, Donald E; Gardner, Timothy J; Lockhart, Peter B; Moliterno, David J; O'Gara, Patrick; Whitlow, Patrick

    2007-05-01

    and Overview. Dual antiplatelet therapy with aspirin and a thienopyridine has been shown to reduce cardiac events after coronary stenting. However, many patients and health care providers prematurely discontinue dual antiplatelet therapy, which greatly increases the risk of stent thrombosis, myocardial infarction and death. This advisory stresses the importance of 12 months of dual antiplatelet therapy after placement of a drug-eluting stent and educating patients and health care providers about hazards of premature discontinuation. It also recommends postponing elective surgery for one year, and if surgery cannot be deferred, considering the continuation of aspirin during the perioperative period in high-risk patients with drug-eluting stents.

  6. Economic Outcomes of Bioresorbable Vascular Scaffolds Versus Everolimus-Eluting Stents in Patients Undergoing Percutaneous Coronary Intervention: 1-Year Results From the ABSORB III Trial.

    PubMed

    Baron, Suzanne J; Lei, Yang; Chinnakondepalli, Khaja; Vilain, Katherine; Magnuson, Elizabeth A; Kereiakes, Dean J; Ellis, Stephen G; Stone, Gregg W; Cohen, David J

    2017-04-24

    The purpose of this study was to evaluate the economic impact of the Absorb bioresorbable vascular scaffold compared with the Xience everolimus-eluting stent in patients undergoing percutaneous coronary intervention. The ABSORB III trial (Everolimus-Eluting Bioresorbable Scaffolds for Coronary Artery Disease) demonstrated that the Absorb scaffold was noninferior to the Xience stent with respect to target lesion failure at 1 year. Whether health care costs differ between the Absorb scaffold and the Xience stent is unknown. We performed a prospective health economic study alongside the ABSORB III trial, in which patients undergoing percutaneous coronary intervention for stable or unstable angina were randomized to receive the Absorb scaffold (n = 1,322) or Xience stent (n = 686). Resource use data were collected through 1 year of follow-up. Costs were assessed using resource-based accounting (for procedures), MedPAR data (for other index hospitalization costs), and Medicare reimbursements (for follow-up costs and physician fees). Initial procedural costs were higher with the Absorb scaffold than the Xience stent ($6,316 ± 1,892 vs. $6,103 ± 1,895; p = 0.02), driven mainly by greater balloon catheter use and the higher cost of the scaffold in the Absorb group. Nonetheless, index hospitalization costs ($15,035 ± 2,992 for Absorb vs. $14,903 ± 3,449 for Xience; p = 0.37) and total 1-year costs ($17,848 ± 6,110 for Absorb vs. $17,498 ± 7,411 for Xience; p = 0.29) were similar between the 2 groups. Although initial procedural costs were higher with the Absorb scaffold, there were no differences in total 1-year health care costs between the 2 cohorts. Longer term follow-up is needed to determine whether meaningful cost savings emerge after scaffold resorption. (A Clinical Evaluation of Absorb™ BVS, the Everolimus-Eluting Bioresorbable Vascular Scaffold in the Treatment of Subjects With de Novo Native Coronary Artery Lesions; NCT01751906). Copyright © 2017

  7. Long-term (>3 Years) outcome and predictors of clinical events after insertion of sirolimus-eluting stent in one or more native coronary arteries (from the Israeli arm of the e-Cypher registry).

    PubMed

    Planer, David; Beyar, Rafael; Almagor, Yaron; Banai, Shmuel; Guetta, Victor; Miller, Hilton; Kornowski, Ran; Brandes, Simcha; Krakover, Ricardo; Solomon, Mivi; Lotan, Chaim

    2008-04-01

    The aim of this study was to evaluate long-term (3.4 years) outcomes and predictors of clinical events in patients treated with sirolimus-eluting stents in the Israeli arm of the e-Cypher registry. From July 2002 to October 2003, 488 patients from 8 medical centers in Israel were enrolled in the e-Cypher registry. Nineteen patients with interventions in venous grafts were excluded from the final analysis. Long-term follow-up was completed for 98% of the remaining patients. There were 29 cases (6.3%) of death (3.9% cardiac and 2.4% noncardiac deaths). According to the broad academic research consortium definition of stent thrombosis, there were 19 cases (4%) of stent thrombosis (incidence density 0.9 cases/100 patient-years). There were 46 cases (9.9%) of target lesion revascularization and 76 cases (16.3%) of major adverse cardiac events (combination of death, myocardial infarction, and target lesion revascularization). Independent predictors of stent thrombosis were renal failure (hazard ratio 9.6, 95% confidence interval 1.9 to 47), stent length (hazard ratio 1.1, 95% confidence interval 1 to 1.2), and the off-label use of sirolimus-eluting stents (hazard ratio 5.3, 95% confidence interval 1.2 to 24). In conclusion, during >3 years of follow-up, stent thrombosis, major adverse cardiac events, and target lesion revascularization continued at constant rates over time. Clinical parameters such as renal failure and procedural parameters such as off-label use and stent length were independent predictors of stent thrombosis.

  8. Bioabsorbable Stent Quo Vadis: A Case for Nano-Theranostics

    PubMed Central

    Gundogan, Buket; Tan, Aaron; Farhatnia, Yasmin; Alavijeh, Mohammad S.; Cui, Zhanfeng; Seifalian, Alexander M.

    2014-01-01

    Percutaneous coronary intervention (PCI) is one of the most commonly performed invasive medical procedures in medicine today. Since the first coronary balloon angioplasty in 1977, interventional cardiology has seen a wide array of developments in PCI. Bare metal stents (BMS) were soon superseded by the revolutionary drug-eluting stents (DES), which aimed to address the issue of restenosis found with BMS. However, evidence began to mount against DES, with late-stent thrombosis (ST) rates being higher than that of BMS. The bioabsorbable stent may be a promising alternative, providing vessel patency and support for the necessary time required and thereafter degrade into safe non-toxic compounds which are reabsorbed by the body. This temporary presence provides no triggers for ST, which is brought about by non-endothelialized stent struts and drug polymers remaining in vivo for extended periods of time. Likewise, nano-theranostics incorporated into a bioabsorbable stent of the future may provide an incredibly valuable single platform offering both therapeutic and diagnostic capabilities. Such a stent may allow delivery of therapeutic particles to specific sites thus keeping potential toxicity to a minimum, improved ease of tracking delivery in vivo by embedding imaging agents, controlled rate of therapy release and protection of the implanted therapy. Indeed, nanocarriers may allow an increased therapeutic index as well as offer novel post-stent implantation imaging and diagnostic methods for atherosclerosis, restenosis and thrombosis. It is envisioned that a nano-theranostic stent may well form the cornerstone of future stent designs in clinical practice. PMID:24672583

  9. Design and rationale for a randomised comparison of everolimus-eluting stents and coronary artery bypass graft surgery in selected patients with left main coronary artery disease: the EXCEL trial.

    PubMed

    Kappetein, Arie Pieter; Serruys, Patrick W; Sabik, Joseph F; Leon, Martin B; Taggart, David P; Morice, Marie-Claude; Gersh, Bernard J; Pocock, Stuart J; Cohen, David J; Wallentin, Lars; Ben-Yehuda, Ori; van Es, Gerrit-Anne; Simonton, Charles A; Stone, Gregg W

    2016-09-18

    Coronary artery bypass graft (CABG) surgery is the standard of care for revascularisation of patients with left main coronary artery disease (LMCAD). Recent studies have suggested that percutaneous coronary intervention (PCI) with drug-eluting stents (DES) may provide comparable outcomes in selected patients with LMCAD without extensive CAD. We therefore designed a trial to investigate whether PCI with XIENCE cobalt-chromium everolimus-eluting stents (CoCr-EES) would result in non-inferior or superior clinical outcomes to CABG in selected patients with LMCAD. The Evaluation of XIENCE versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization (EXCEL) trial is a prospective, open-label, multicentre, international study of 1,900 randomised subjects. Patients with significant LMCAD with a SYNTAX score ≤32 and local Heart Team consensus that the subject is appropriate for revascularisation by both PCI and CABG are consented and randomised 1:1 to undergo PCI using CoCr-EES or CABG. All patients undergo follow-up for five years. The primary endpoint is the three-year composite rate of death, stroke or myocardial infarction, assessed at a median follow-up of at least three years (with at least two-year follow-up in all patients), powered for sequential non-inferiority and superiority testing. The EXCEL study will define the contemporary roles of CABG and PCI using XIENCE CoCr-EES in patients with LMCAD disease with low and intermediate SYNTAX scores.

  10. Angina and Ischemia at 2 Years With Bioresorbable Vascular Scaffolds and Metallic Drug-eluting Stents. ESTROFA Ischemia BVS-mDES Study.

    PubMed

    de la Torre Hernández, José M; Rumoroso, José R; Ojeda, Soledad; Brugaletta, Salvatore; Cascón, José D; Ruisánchez, Cristina; Sánchez Gila, Joaquín; Roa, Jessica; Tizón, Helena; Gutiérrez, Hipólito; Larman, Mariano; García Camarero, Tamara; Pinar, Eduardo; Díaz, José F; Pan, Manuel; Morillas Bueno, Miren; Oyonarte, José M; Ruiz Guerrero, Luis; Ble, Mireia; Rubio Patón, Ramón; Arnold, Román; Echegaray, Kattalin; de la Morena, Gonzalo; Sabate, Manel

    2018-05-01

    Bioresorbable vascular scaffolds (BVS) have the potential to restore vasomotion but the clinical implications are unknown. We sought to evaluate angina and ischemia in the long-term in patients treated with BVS and metallic drug-eluting stents (mDES). Multicenter study including patients with 24 ± 6 months of uneventful follow-up, in which stress echocardiography was performed and functional status was assessed by the Seattle Angina Questionnaire (SAQ). The primary endpoint was a positive result in stress echocardiography. The study included 102 patients treated with BVS and 106 with mDES. There were no differences in the patients' baseline characteristics. Recurrent angina was found in 18 patients (17.6%) in the BVS group vs 25 (23.5%) in the mDES group (P = .37), but SAQ results were significantly better in the BVS group (angina frequency 96.0 ± 8.0 vs 89.2 ± 29.7; P = .02). Stress echocardiography was positive in 11/92 (11.9%) of BVS patients vs 9/96 (9.4%) of mDES patients in the (P = .71) and angina was induced in 2/102 (1.9%) vs 7/106 (6.6%) (P = .18), respectively, but exercise performance was better in the BVS group even in those with positive tests (exercise duration 9.0 ± 2.0minutes vs 7.7 ± 1.8minutes; P = .02). A propensity score matching analysis yielded similar results. The primary endpoint was similar in both groups. In addition, recurrent angina was similar in patients with BVS and mDES. The better functional status, assessed by means of SAQ and exercise performance, detected in patients receiving BVS should be confirmed in further studies. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  11. Impact of high lipoprotein(a) levels on in-stent restenosis and long-term clinical outcomes of angina pectoris patients undergoing percutaneous coronary intervention with drug-eluting stents in Asian population.

    PubMed

    Park, Sang-Ho; Rha, Seung-Woon; Choi, Byoung-Geol; Park, Ji-Young; Jeon, Ung; Seo, Hong-Seog; Kim, Eung-Ju; Na, Jin-Oh; Choi, Cheol-Ung; Kim, Jin-Won; Lim, Hong-Euy; Park, Chang-Gyu; Oh, Dong-Joo

    2015-06-01

    Lipoprotein(a) (Lp(a)) is known to be associated with cardiovascular complications and atherothrombotic properties in general populations. However, it has not been examined whether Lp(a) levels are able to predict adverse cardiovascular outcomes in patients undergoing percutaneous coronary intervention (PCI) with drug-eluting stents (DES). A total of 595 consecutive patients with angina pectoris who underwent elective PCI with DES were enrolled from 2004 to 2010. The patients were divided into two groups according to the levels of Lp(a): Lp(a) < 50 mg/dL (n = 485 patients), and Lp(a) ≥ 50 mg/dL (n = 111 patients). The 6-9-month angiographic outcomes and 3-year cumulative major clinical outcomes were compared between the two groups. Binary restenosis occurred in 26 of 133 lesions (19.8%) in the high Lp(a) group and 43 of 550 lesions (7.9%) in the low Lp(a) group (P = 0.001). In multivariate analysis, the reference vessel diameter, low density lipoprotein cholesterol, total lesion length, and Lp(a) ≥ 50 mg/dL were predictors of binary restenosis. In the Cox proportional hazards regression analysis, Lp(a) > 50 mg/dL was significantly associated with the 3-year adverse clinical outcomes including any myocardial infarction, revascularization (target lesion revascularization (TLR) and target vessel revascularization (TVR)), TLR-major adverse cardiac events (MACEs), TVR-MACE, and All-MACEs. In our study, high Lp(a) level ≥ 50 mg/dL in angina pectoris patients undergoing elective PCI with DES was significantly associated with binary restenosis and 3-year adverse clinical outcomes in an Asian population. © 2015 Wiley Publishing Asia Pty Ltd.

  12. Percutaneous coronary intervention with oral sirolimus and bare metal stents has comparable safety and efficacy to treatment with drug eluting stents, but with significant cost saving: long-term follow-up results from the randomised, controlled ORAR III (Oral Rapamycin in ARgentina) study.

    PubMed

    Rodriguez, Alfredo E; Maree, Andrew; Tarragona, Sonia; Fernandez-Pereira, Carlos; Santaera, Omar; Rodriguez Granillo, Alfredo M; Rodriguez-Granillo, Gaston A; Russo-Felssen, Miguel; Kukreja, Neville; Antoniucci, David; Palacios, Igor F; Serruys, Patrick W

    2009-06-01

    Previous randomised studies have shown a significant reduction in restenosis when oral rapamycin (OR) is administered to patients undergoing bare metal stent (BMS) implantation. How this regimen compares to drug eluting stents (DES) is unknown. Two-hundred patients with de novo coronary lesions were randomised to treatment with OR plus BMS (100 pts) or with DES (100 pts). OR was given as a bolus of 10 mg per day before PCI followed by daily doses of 3 mg during following 13 days. Primary endpoints were to compare hospital, follow-up and overall cost at one, two, three and five years of follow-up. The secondary endpoints included death, myocardial infarction (MI) and stroke and were analysed as major adverse cardiovascular events (MACCE). Target vessel (TVR) and target lesion revascularisation (TLR) were independently analysed. Costs included procedural resources, hospitalisation, medications, repeat revascularisation procedures and professional fees. Baseline demographic, clinical and angiographic characteristics were similar. At 18.3 +/- 7 months of follow-up, the initial strategy of OR plus BMS resulted in significant cost saving when compared to DES (p=0.0001). TLR rate was 8.2% with DES and 7.0% with OR plus BMS (p=0.84), similarly no differences in TVR rate in both groups was seen (10.6% and 10.5% in OR and DES group respectively, p=0.86). Non-inferiority testing, determined that DES therapy failed to be cost saving compared to OR in all possible cost scenarios. A strategy of OR plus BMS is cost saving compared to DES in patients undergoing PCI for de novo coronary lesions.

  13. Percutaneous treatment with drug-eluting stent vs bypass surgery in patients suffering from chronic stable angina with multivessel disease involving significant proximal stenosis in left anterior descending artery.

    PubMed

    Yan, Qiao; Changsheng, Ma; Shaoping, Nie; Xiaohui, Liu; Junping, Kang; Qiang, Lv; Xin, Du; Rong, Hu; Yin, Zhang; Changqi, Jia; Jiahui, Wu; Xinmin, Liu; Jianzeng, Dong; Fang, Chen; Yujie, Zhou; Shuzheng, Lv; Fangjiong, Huang; Chengxiong, Gu; Xuesi, Wu

    2009-10-01

    The aim of the present study was to compare the effects of drug-eluting stents (DES) and coronary artery bypass grafting (CABG) in patients suffering from chronic stable angina with multivessel disease, involving significant proximal stenosis in the left anterior descending artery (LAD). All consecutive patients suffering from chronic stable angina with multivessel disease involving significant proximal LAD stenosis underwent DES implantation (n=600) or CABG (n=709) at our institution. At 2 years, the unadjusted mortality was significantly lower in the DES group than in the CABG group (2.2% vs 5.2%, P=0.004), but the adjusted risk of death was similar (odds ratio (OR) 0.74, 95%CI 0.28-1.97, P=0.555). Furthermore, both the adjusted rate of nonfatal myocardial infarction and cerebrovascular events was also comparable. However, the unadjusted and adjusted risk of major adverse cardiac cerebrovascular events in the DES was significantly higher than in the CABG (13.3% vs 9.6%, OR 2.71, 95%CI 1.56-4.74, P<0.001), which is probably attributed to the higher subsequent revascularization rate after DES implantation. DES showed comparable long-term mortality for the treatment of multivessel disease involving significant proximal stenosis in LAD in comparison with CABG.

  14. Tracheal Self-Expandable Metallic Stents: A Comparative Study of Three Different Stents in a Rabbit Model.

    PubMed

    Serrano, Carolina; Lostalé, Fernando; Rodríguez-Panadero, Francisco; Blas, Ignacio de; Laborda, Alicia; de Gregorio, Miguel Angel

    2016-03-01

    The objective of this study was to assess tracheal reactivity after the deployment of different self-expandable metal stents (SEMS). Forty female New Zealand rabbits were divided into four groups. Three groups received three different SEMS: steel (ST), nitinol (NiTi), or nitinol drug-eluting stent (DES); the fourth group was the control group (no stent). Stents were deployed percutaneously under fluoroscopic guidance. Animals were assessed by multi-slice, computed tomography (CT) scans, and tracheas were collected for anatomical pathology (AP) study. Data from CT and AP were statistically analyzed and correlated. The DES group had the longest stenosis (20.51±14.08mm vs. 5.84±12.43 and 6.57±6.54mm in NiTi and ST, respectively, day 30; P<.05), and higher granuloma formation on CT (50% of cases). The NiTi group showed the lowest grade of stenosis (2.86±6.91% vs. 11.28±13.98 and 15.54±25.95% in DES and ST, respectively; P<.05). The AP study revealed that the ST group developed intense proliferative reactivity compared to the other groups. In the DES group, a destructive response was observed in 70% of the animals, while the NiTi was the least reactive stent. CT was more effective in detecting wall thickening (positive correlation of 68.9%; P<.001) than granuloma (not significant). The ST group developed granulomas and significant stenosis. NiTi was the least reactive stent, while DES caused significant lesions that may be related to drug dosage. This type of DES stent is therefore not recommended for the treatment of tracheobronchial stenosis. Copyright © 2015 SEPAR. Published by Elsevier Espana. All rights reserved.

  15. Coronary Stents: The Impact of Technological Advances on Clinical Outcomes.

    PubMed

    Mennuni, Marco G; Pagnotta, Paolo A; Stefanini, Giulio G

    2016-02-01

    Percutaneous coronary interventions (PCI) were proposed in the late 1970s as an alternative to surgical coronary artery bypass grafting for the treatment of coronary artery disease. Important technological progress has been made since. Balloon angioplasty was replaced by bare metal stents, which allowed to permanently scaffold the coronary vessel avoiding acute recoil and abrupt occlusion. Thereafter, the introduction of early generation drug-eluting stents (DES) has significantly improved clinical outcomes, primarily by markedly reducing the risk of restenosis. New generation DES with thinner stent struts, novel durable or biodegradable polymer coatings, and new limus antiproliferative agents, have further improved upon the safety and efficacy profile of early generation DES. The present article aims to review the impact of technological advances on clinical outcomes in the field of PCI with coronary stents, and to provide a brief overview on clinical margins of improvement and unmet needs of available DES.

  16. Targeted stent use in clinical practice based on evidence from the Basel Stent Cost Effectiveness Trial (BASKET).

    PubMed

    Brunner-La Rocca, Hans-Peter; Kaiser, Christoph; Pfisterer, Matthias

    2007-03-01

    It is unknown which patients benefit most from drug-eluting stents (DES) against bare-metal stents (BMS) in a long-term clinical outcome. To address this question, data from 826 consecutive patients with angioplasty, randomized 2:1 to DES vs. BMS, with an 18-month follow-up for cardiac death/myocardial infarction (MI) and non-MI-related target-vessel revascularization (TVR) were analysed for interactions between stent type and patient/vessel characteristics predicting events. Rates of 18-month TVRs were lower with DES vs. BMS use (7.5 vs. 11.6%, P = 0.05), but similar for both stents regarding cardiac death/MI (DES, 8.4%; BMS, 7.5%; P = 0.70). Significant interactions between stent type and two multivariable event predictors were identified: small stents (<3.0 mm) and bypass graft stenting. In these patient groups together (n = 268, 32%), DES reduced non-MI-related TVR (HR = 0.44; P = 0.02) and cardiac death/MI (HR = 0.44; P = 0.04), whereas in the other 558 patients (68%) TVR rate was similar (HR = 0.75; P = 0.38) and cardiac death/MI rate increased after DES (HR = 2.07; P = 0.05). Patients with angioplasty of small vessels or bypass grafts seem to benefit from DES use, in long-term outcome, in contrast to patients with large native vessel stenting where there might even be late harm. Still, this hypothesis needs to be tested prospectively.

  17. Role of Animal Models in Coronary Stenting.

    PubMed

    Iqbal, Javaid; Chamberlain, Janet; Francis, Sheila E; Gunn, Julian

    2016-02-01

    Coronary angioplasty initially employed balloon dilatation only. This technique revolutionized the treatment of coronary artery disease, although outcomes were compromised by acute vessel closure, late constrictive remodeling, and restenosis due to neointimal proliferation. These processes were studied in animal models, which contributed to understanding the biology of endovascular arterial injury. Coronary stents overcome acute recoil, with improvements in the design and metallurgy since then, leading to the development of drug-eluting stents and bioresorbable scaffolds. These devices now undergo computer modeling and benchtop and animal testing before evaluation in clinical trials. Animal models, including rabbit, sheep, dog and pig are available, all with individual benefits and limitations. In smaller mammals, such as mouse and rabbit, the target for stenting is generally the aorta; whereas in larger animals, such as the pig, it is generally the coronary artery. The pig coronary stenting model is a gold-standard for evaluating safety; but insights into biomechanical properties, the biology of stenting, and efficacy in controlling neointimal proliferation can also be gained. Intra-coronary imaging modalities such as intravascular ultrasound and optical coherence tomography allow precise serial evaluation in vivo, and recent developments in genetically modified animal models of atherosclerosis provide realistic test beds for future stents and scaffolds.

  18. Heparin monotherapy or bivalirudin during percutaneous coronary intervention in patients with non-ST-segment-elevation acute coronary syndromes or stable ischemic heart disease: results from the Evaluation of Drug-Eluting Stents and Ischemic Events registry.

    PubMed

    Bangalore, Sripal; Pencina, Michael J; Kleiman, Neal S; Cohen, David J

    2014-06-01

    The use of bivalirudin versus unfractionated heparin monotherapy in patients without ST-segment-elevation myocardial infarction is not well defined. The study population consisted of patients enrolled in the Evaluation of Drug-Eluting Stents and Ischemic Events (EVENT) registry with either non-ST-segment-elevation acute coronary syndromes or stable ischemic heart disease, who underwent percutaneous coronary intervention with either unfractionated heparin or bivalirudin monotherapy. Propensity score matching was used to adjust for baseline characteristics. The primary bleeding (in-hospital composite bleeding-access site bleeding, thrombolysis in myocardial infarction major/minor bleeding, or transfusion) and primary (in-hospital death/myocardial infarction) and secondary ischemic outcomes (death/myocardial infarction/unplanned repeat revascularization at 12 months) were evaluated. Propensity score matching yielded 1036 patients with non-ST-segment-elevation acute coronary syndromes and 2062 patients with stable ischemic heart disease. For the non-ST-segment-elevation acute coronary syndrome cohort, bivalirudin use was associated with lower bleeding (difference, -3.3% [-0.8% to -5.8%]; P=0.01; number need to treat=30) without increase in either primary (difference, 1.2% [4.1% to -1.8%]; P=0.45) or secondary ischemic outcomes, including stent thrombosis (difference, 0.0% [1.3% to -1.3%]; P=1.00). Similarly, in the stable ischemic heart disease cohort, bivalirudin use was associated with lower bleeding (difference, -1.8% [-0.4% to -3.3%]; P=0.01; number need to treat=53) without increase in either primary (difference, 0.4% [2.3% to -1.5%]; P=0.70) or secondary ischemic outcomes, including stent thrombosis (difference, 0.0% [0.7% to -0.7%]; P=1.00) when compared with unfractionated heparin monotherapy. Among patients with non-ST-segment-elevation acute coronary syndromes or stable ischemic heart disease undergoing percutaneous coronary intervention, bivalirudin use

  19. Stent-based delivery of adeno-associated viral vectors with sustained vascular transduction and iNOS-mediated inhibition of in-stent restenosis

    PubMed Central

    Fishbein, Ilia; Guerrero, David T.; Alferiev, Ivan S.; Foster, Jonathan B.; Minutolo, Nicholas G.; Chorny, Michael; Mas Monteys, Alejandro; Driesbaugh, Kathryn H.; Nagaswami, Chandrasekaran; Levy, Robert J.

    2017-01-01

    In-stent restenosis remains an important clinical problem in the era of drug eluting stents. Development of clinical gene therapy protocols for the prevention and treatment of in-stent restenosis is hampered by the lack of adequate local delivery systems. Herein we describe a novel stent-based gene delivery platform capable of providing local arterial gene transfer with adeno-associated viral (AAV) vectors. This system exploits the natural affinity of protein G (PrG) to bind to the Fc region of mammalian IgG, making PrG a universal adaptor for surface immobilization of vector-capturing antibodies (Ab). Our results: 1) demonstrate the feasibility of reversible immobilization of AAV2 vectors using vector tethering by AAV2-specific Ab appended to the stent surface through covalently attached PrG, 2) show sustained release kinetics of PrG/Ab-immobilized AAV2 vector particles into simulated physiological medium in vitro and site-specific transduction of cultured cells, 3) provide evidence of long-term (12 weeks) arterial expression of luciferase with PrG/Ab-tethered AAV2Luc, and 4) show anti-proliferative activity and anti-restenotic efficacy of stent-immobilized AAV2iNOS in the rat carotid artery model of stent angioplasty. PMID:28832561

  20. Study design of the influence of SErotonin inhibition on patients with RENAl impairment or diabetes undergoing drug-eluting stent implantation (SERENADE) study: A multicenter, open-label, prospective, randomized study.

    PubMed

    Lee, Seung-Ah; Suh, Jung-Won; Park, Jin Joo; Yoon, Chang-Hwan; Cho, Young-Suk; Youn, Tae-Jin; Chae, In-Ho; Kim, Hyo-Soo; Kim, Sang-Hyun; Choi, Dong-Ju

    2015-07-01

    The rates of stent failure after percutaneous coronary intervention have decreased since the introduction of the drug-eluting stent (DES). However, chronic kidney disease (CKD) and diabetes mellitus (DM) remain strong clinical predictors of poor prognosis despite DES implantation. Sarpogrelate, a selective serotonin (5-hydroxytryptamine (HT)2a [5-HT2A]) receptor antagonist, has antiproliferative effects, reducing neointimal hyperplasia and smooth muscle cell proliferation, as well as potent antiplatelet action, inhibiting 5-HT-induced platelet aggregation. However, efficacy and safety data for sarpogrelate in patients with CKD or DM are limited. We aim to determine whether sarpogrelate has beneficial effects in patients with CDK or DM treated with DES implantation. The SERENADE trial is a multicenter, open-label, prospective, randomized study that will test the superiority of triple anti-platelet therapy (TAT; aspirin, clopidogrel, and sarpogrelate) to conventional dual antiplatelet therapy (DAT; aspirin and clopidogrel) in preventing late lumen loss 9 months after the index procedure in patients with CKD or DM. A total of 220 patients diagnosed with coronary artery disease with DM or CKD will be randomized to the TAT or DAT groups (1:1 ratio) after DES implantation. The primary endpoint is late lumen loss at 9 months assessed by quantitative coronary angiography. Secondary efficacy endpoints are composites of major adverse cardiovascular events including cardiac death, nonfatal myocardial infarction, and target lesion revascularization. Secondary safety endpoints are major bleeding events and hepatic or renal impairment. The SERENADE trial will provide insight on the efficacy of adjunctive therapy with sarpogrelate after DES implantation for patients with high-risk profiles such as CKD or DM. National Institutes of Health Clinical Trials Registry (ClinicalTrials.gov NCT02294643). Copyright © 2015. Published by Elsevier Inc.

  1. Re-examining minimal luminal diameter relocation and quantitative coronary angiography--intravascular ultrasound correlations in stented saphenous vein grafts: methodological insights from the randomised RRISC trial.

    PubMed

    Semeraro, Oscar; Agostoni, Pierfrancesco; Verheye, Stefan; Van Langenhove, Glenn; Van den Heuvel, Paul; Convens, Carl; Van den Branden, Frank; Bruining, Nico; Vermeersch, Paul

    2009-03-01

    Angiographic parameters (such as late luminal loss) are common endpoints in drug-eluting stent trials, but their correlation with the neointimal process and their reliability in predicting restenosis are debated. Using quantitative coronary angiography (QCA) data (49 bare metal stent and 44 sirolimus-eluting stent lesions) and intravascular ultrasound (IVUS) data (39 bare metal stent and 34 sirolimus-eluting stent lesions) from the randomised Reduction of Restenosis In Saphenous vein grafts with Cypher stent (RRISC) trial, we analysed the "relocation phenomenon" of QCA-based in-stent minimal luminal diameter (MLD) between post-procedure and follow-up and we correlated QCA-based and IVUS-based restenotic parameters in stented saphenous vein grafts. We expected the presence of MLD relocation for low late loss values, as MLD can "migrate" along the stent if minimal re-narrowing occurs, while we anticipated follow-up MLD to be located close to post-procedural MLD position for higher late loss. QCA-based MLD relocation occurred frequently: the site of MLD shifted from post-procedure to follow-up an "absolute" distance of 5.8 mm [2.5-10.2] and a "relative" value of 29% [10-46]. MLD relocation failed to correlate with in-stent late loss (rho = 0.14 for "absolute" MLD relocation [p = 0.17], and rho=0.03 for "relative" relocation [p = 0.811). Follow-up QCA-based and IVUS-based MLD values well correlated in the overall population (rho = 0.76, p < 0.001), but QCA underestimated MLD on average 0.55 +/- 0.49 mm, and this was mainly evident for lower MLD values. Conversely, the location of QCA-based MLD failed to correlate with the location of IVUS-based MLD (rho = 0.01 for "absolute" values--in mm [p = 0.911, rho = 0.19 for "relative" values--in % [p = 0.111). Overall, the ability of late loss to "predict" IVUS parameters of restenosis (maximum neointimal hyperplasia diameter, neointimal hyperplasia index and maximum neointimal hyperplasia area) was moderate (rho between 0

  2. Accelerated Recovery of Endothelium Function after Stent Implantation with the Use of a Novel Systemic Nanoparticle Curcumin.

    PubMed

    Lu, Qi; Ye, Fang; Yang, Xiangjun; Gu, Qingqing; Wang, Peng; Zhu, Jianhua; Shen, Li; Gong, Feirong

    2015-01-01

    Curcumin was reported to exhibit a wide range of pharmacological effects including antioxidant, anti-inflammatory, and antiproliferative activities and significantly prevent smooth muscle cells migration. In the present study, a novel kind of curcumin loaded nanoparticles (Cur-NP) has been prepared and characterized with the aim of inhibiting inflammation formation and accelerating the healing process of the stented arteries. Cur-NP was administrated intravenously after stent implantation twice a week and detailed tissue responses were evaluated. The results demonstrated that intravenous administration of Cur-NP after stent implantation accelerated endothelial cells restoration and endothelium function recovery and may potentially be an effective therapeutic alternative to reduce adverse events for currently available drug eluting stents.

  3. Stent-based nitric oxide delivery reducing neointimal proliferation in a porcine carotid overstretch injury model.

    PubMed

    Hou, Dongming; Narciso, Hugh; Kamdar, Kirti; Zhang, Ping; Barclay, Bruce; March, Keith L

    2005-01-01

    The effects of nitric acid (NO) on vessel response to injury include the inhibition of platelet adhesion, platelet aggregation, leukocyte adhesion and smooth muscle cell proliferation. Releasing NO from a stent might reduce the clinical problem of restenosis. The present study was designed to examine whether an NO-eluting covered stent can prevent neointimal formation in a porcine carotid overstretch injury model. The interior of a self-expanding polytetrafluoroethylene (ePTFE)-covered aSpire stent was coated with silicone, which contained 23.6 microg or 54.5 microg sodium nitroprusside (SNP, NO-releasing compound). The stent was implanted into carotid artery. Six pigs were implanted with stents, one high-dose SNP and one uncoated control, following balloon overstretch injury of the carotid artery with a balloon-to-artery ratio of 1.3:1. No local or systemic toxicity was evidenced in the six pigs after carotid artery implantation with either low- or high-dose stents within a week. At day 28, the mean intimal thickness was 0.12 +/- 0.05 mm for NO-eluting stents and 0.43 +/- 0.09 mm for uncoated stents (p = 0.008). The mean neointimal area was reduced from 2.40 +/- 0.39 mm2 for control stents to 0.49 +/- 0.16 mm2 for NO-eluting stents (p < 0.0001), which resulted in a 24% reduction of angiographic vessel narrowing. The NO-eluting ePTFE-covered stent is feasible and effectively reduces in-stent neointimal hyperplasia at 28 days in a porcine carotid overstretch model.

  4. Sirolimus‐eluting stent treatment for unprotected versus protected left main coronary artery disease in widespread clinical routine: 6‐month and 3‐year clinical follow‐up results from the prospective multicentre German Cypher Registry

    PubMed Central

    Khattab, Ahmed A; Hamm, Christian W; Senges, Jochen; Toelg, Ralph; Geist, Volker; Bonzel, Tassilo; Kelm, Malte; Levenson, Benny; Neumann, Franz‐Josef; Nienaber, Christoph A; Pfannebecker, Thomas; Sabin, Georg; Schneider, Steffen; Tebbe, Ulrich; Richardt, Gert

    2007-01-01

    Background Percutaneous coronary intervention (PCI) of left main coronary artery (LMCA) disease in the bare stent era was limited by high restenosis rates which eventually resulted in sudden death in unprotected cases. Clinical and angiographic restenosis has been substantially reduced by drug‐eluting stents, reviving therefore this indication for PCI despite the absence of direct comparative studies with coronary artery bypass graft surgery. Objective To assess the acute, mid‐ and long‐term outcomes of patients treated with sirolimus‐eluting stents for unprotected LMCA stenoses and to compare them with those treated for protected LMCA disease in the same time period from the German Cypher Registry. Setting and patients The German Cypher Registry included 6755 patients. Eighty‐two patients treated for unprotected LMCA disease were compared with 118 patients treated for protected LMCA stenoses. All patients were treated by sirolimus‐eluting stents. The primary end point was death, myocardial infarction (MI) and target vessel revascularisation at 6 months' follow‐up. Survival free of MI at the long term was considered as the safety end point. Results One‐third of the patients in both groups were treated for the distal left main bifurcation. Angiographic success was 98.5% for both groups. The cumulative combined incidence of all‐cause death, non‐fatal MI and target vessel revascularisation at 6 months was 14.1% in the unprotected LMCA group and 13.1% in the protected group (hazard ratio = 0.81 (95% CI 0.37 to 1.74), p = 0.8). At long‐term, death/MI were reported among 20.2% (95% CI 13.5% to 29.6%) of the protected group versus 11.8% (95% CI 6.3% to 21.4%) of the unprotected group (p = 0.2). Conclusion Sirolimus‐eluting stent treatment of unprotected and protected LMCA stenoses is technically feasible in widespread routine clinical use. Acceptable long‐term clinical results can be achieved, with no particular safety concerns

  5. A new era of prospective real-world safety evaluation primary report of XIENCE V USA (XIENCE V Everolimus Eluting Coronary Stent System condition-of-approval post-market study).

    PubMed

    Krucoff, Mitchell W; Rutledge, David R; Gruberg, Luis; Jonnavithula, Lalitha; Katopodis, John N; Lombardi, William; Mao, Vivian W; Sharma, Samin K; Simonton, Charles A; Tamboli, Hoshedar P; Wang, Jin; Wilburn, Olivia; Zhao, Weiying; Sudhir, Krishnankutty; Hermiller, James B

    2011-12-01

    The XIENCE V USA (XIENCE V Everolimus Eluting Coronary Stent System Condition-of-Approval Post-Market study) sought to: 1) evaluate the safety of everolimus-eluting coronary stent systems (EECSS) in a contemporary cohort of real-world subjects; and 2) prospectively test the quality of event reporting with analysis of matched patients from the randomized SPIRIT IV (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Subjects With de Novo Native Coronary Artery Lesions) trial. Randomized trials have demonstrated the safety and efficacy of EECSS in selected "standard-risk" patients. The XIENCE V USA trial was a prospective, multicenter, single-arm study in unselected patients. The primary endpoint was Academic Research Consortium (ARC)-defined definite and probable stent thrombosis (ST); the co-primary endpoint was the composite of cardiac death and myocardial infarction at 1 year. Secondary analyses included: 1) stratification by standard-risk and extended-risk cohorts; and 2) late ST after dual antiplatelet therapy interruption. Of 5,054 participants (1,875 standard-risk; 3,179 extended-risk), 4,958 (98.1%) reached 1-year follow-up. The rate of ARC-defined definite and probable ST was 0.84% (95% confidence interval [CI]: 0.60% to 1.14%) in the overall population and 0.33% (95% CI: 0.12% to 10.72%) and 1.14% (95% CI: 0.80% to 11.58%) in the standard-risk and extended-risk cohorts, respectively. No late ST was observed after dual antiplatelet therapy interruption in either cohort after 6 months. The composite rate of cardiac death and ARC-defined myocardial infarction was 6.5% (95% CI: 5.79% to 17.17%) in the overall population, 3.8% (95% CI: 2.98% to 14.78%) in the standard-risk cohort, and 8.0% (95% CI: 7.09% to 19.02%) in the extended-risk cohort. This study comprehensively reports ST rates for EECSS in a contemporary real-world population. The absence of ST after dual antiplatelet therapy interruption beyond 6 months in

  6. Efficacy of stent angioplasty for symptomatic stenoses of the proximal vertebral artery.

    PubMed

    Weber, W; Mayer, T E; Henkes, H; Kis, B; Hamann, G F; Holtmannspoetter, M; Brueckmann, H; Kuehne, D

    2005-11-01

    To evaluate the safety and efficacy of stent angioplasty in the treatment of symptomatic arteriosclerotic stenoses of the proximal vertebral artery (VA). Thirty-eight symptomatic stenoses of the vertebral origin were treated with flexible balloon-expandable coronary stents. Angiographic and clinical follow-up examinations were obtained in 26 patients at a mean of 11 months. The immediate post-procedural angiographic results showed no residual stenosis in 33 vessels and mild residual stenoses in five vessels. Periprocedurally, there were two asymptomatic technical complications and one TIA. During follow-up re-stenosis could be detected in 10 cases (36%), and vessel occlusions in two patients. Two stents were broken. One of the restenosis caused a TIA within the follow-up period. Flexible balloon-expandable coronary stents proved to be save and effective in preventing vertebrobasilar stroke but were incapable to preserve the proximal vertebral artery lumen. For the VA origine an adequate stent, self-expanding, bioresorbable, or drug-eluting has to be found.

  7. [Immediate and Long-term Results of the First in Russia of IntrocoronaryMetal Stent in the Coronary Artery].

    PubMed

    Babunashvili, A M; Navtsishvili, Z G; Konstantinov, B A

    2016-02-01

    The authors present immediate and long term results of the first in Russia implantation in coronary artery of Palmaz-Shatz metal stent. Indications for stenting were urgent after complicated dissection as a result of balloon dilation of discrete bifurcational stenosis of anterior interventricular artery (IVA). Immediate angiographic and clinical result was good. At control angiography after 13 years their was no restenosis in stented IVA. However novel narrowing was found in left main coronary artery (LMCA) in which drug eluting stent was implanted. Coronary angiography carried out after 7.5 years after stenting of LMCA and in 20 years after stent implantation in IVA revealed good patency of both stented segments without signs of restenosis. This case report demonstrates possibility of long term preservation of angiographic and clinical effect of staged endovascular treatment of coronary atherosclerosis.

  8. Prevention of premature discontinuation of dual antiplatelet therapy in patients with coronary artery stents: a science advisory from the American Heart Association, American College of Cardiology, Society for Cardiovascular Angiography and Interventions, American College of Surgeons, and American Dental Association, with representation from the American College of Physicians.

    PubMed

    Grines, Cindy L; Bonow, Robert O; Casey, Donald E; Gardner, Timothy J; Lockhart, Peter B; Moliterno, David J; O'Gara, Patrick; Whitlow, Patrick

    2007-02-15

    Dual antiplatelet therapy with aspirin and a thienopyridine has been shown to reduce cardiac events after coronary stenting. However, many patients and healthcare providers prematurely discontinue dual antiplatelet therapy, which greatly increases the risk of stent thrombosis, myocardial infarction, and death. This advisory stresses the importance of 12 months of dual antiplatelet therapy after placement of a drug-eluting stent and educating the patient and healthcare providers about hazards of premature discontinuation. It also recommends postponing elective surgery for 1 year, and if surgery cannot be deferred, considering the continuation of aspirin during the perioperative period in high-risk patients with drug-eluting stents. (c) 2007 the American Heart Association, Inc., the American College of Cardiology Foundation, the Society for Cardiovascular Angiography and Interventions, the American College of Surgeons, and the American Dental Association

  9. First-in-man study evaluating the safety and efficacy of a second generation biodegradable polymer sirolimus-eluting stent in the treatment of patients with de novo coronary lesions: clinical, Angiographic, and OCT outcomes of CREDIT-1.

    PubMed

    Wang, Geng; Sun, Zhongwei; Jin, Quanmin; Xu, Kai; Li, Yi; Wang, Xiaozeng; Ma, Yingyan; Liu, Haiwei; Zhao, Xin; Wang, Bin; Deng, Jie; Guan, Shaoyi; Ge, Meiling; Wang, Xiaoyan; Xu, Bo; Han, Yaling

    2015-03-01

    To evaluate the preliminary safety and efficacy of the EXCEL II stent system. Although the first biodegradable polymer drug-eluting stent (BP-DES), EXCEL, was launched nearly a decade ago, in-stent restenosis and stent thrombosis remain pertinent clinical problems in practice. A new cobalt-chromium BP-DES EXCEL II has been developed with the aim of improving stent safety and efficacy. Forty-five patients with single de novo native coronary lesions were enrolled and randomized to two groups in a 2:1 ratio, the 4-month follow-up group (n = 30) and the 12-month follow-up group (n = 15). All patients underwent percutaneous coronary intervention (PCI) with the EXCEL II stent system. Quantitative coronary angiography (QCA) and optical coherence tomography (OCT) were used to assess coronary vasculature at the designated 4- or 12-month follow-up. The primary outcome was major adverse cardiac events (MACE) at 30 days post-PCI. No MACE, thrombotic events, or target lesion failure was found in the 45 patients during the 12-month follow-up. There was no significant difference (P > 0.05) between the two groups in terms of in-stent and in-segment late lumen loss (LLL). No in-stent and in-segment restenosis was found in either group. At follow-up, the ratio of >10% uncovered struts per lesion was 26.67% in the 4-month group and 0% in the 12-month group (P < 0.05). Neointimal coverage in the 12-month group was significantly better than in the 4-month group (98.58% vs. 93.51%, P < 0.01). This first-in-man study demonstrates promising feasibility, safety, and efficacy of EXCEL II stents. These stents were found to have rapid endothelialization and low LLL rates at 4 and 12 months after implantation. © 2015 Wiley Periodicals, Inc.

  10. 5-Year Safety and Efficacy of Resolute Zotarolimus-Eluting Stent: The RESOLUTE Global Clinical Trial Program.

    PubMed

    Yeh, Robert W; Silber, Sigmund; Chen, Lianglong; Chen, Shaoliang; Hiremath, Shirish; Neumann, Franz-Josef; Qiao, Shubin; Saito, Shigeru; Xu, Bo; Yang, Yuejin; Mauri, Laura

    2017-02-13

    The authors evaluated the 5-year cumulative incidence of cardiovascular events following Resolute zotarolimus-eluting stent (R-ZES) implantation. Individual trials are often underpowered to show differences for low-frequency adverse events. The R-ZES was studied in 10 prospective clinical trials, designed with identical adverse event definitions, ascertainment, and adjudication. The RESOLUTE Global Clinical Trial Program includes 7,618 patients treated with R-ZES: RESOLUTE first-in-human study (N = 139), RESOLUTE All Comers (N = 1,140), RESOLUTE International (N = 2,349), RESOLUTE US (N = 1,402), RESOLUTE US 38 mm (N = 114), RESOLUTE Japan (N = 100), RESOLUTE Japan Small Vessel Study (N = 65), RESOLUTE Asia (N = 311), RESOLUTE China Randomized Controlled Trial (N = 198), and RESOLUTE China Registry (N = 1,800). The 5-year cumulative incidence of events was calculated. The 5-year cumulative incidence of cardiac events was 13.4% for target lesion failure and included 5.0% cardiac death, 4.4% target vessel myocardial infarction, and 6.3% clinically driven target lesion revascularization. Dual-antiplatelet therapy at 1, 3, and 5 years was 91%, 37%, and 32%, respectively. The 5-year cumulative incidence of definite or probable stent thrombosis was 1.2%, which comprised 0.7% at 1 year and an annualized rate of 0.1% thereafter. Five-year use of dual-antiplatelet therapy varied geographically from 63% in Japan to 11% in Europe. In the largest group of R-ZES patients examined to date, the majority of stent-related events, including target vessel myocardial infarction and stent thrombosis, occurred within the first year of implantation with much lower risks of these events out to 5 years. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  11. Interactions between Co-Habitating fungi Elicit Synthesis of Taxol from an Endophytic Fungus in Host Taxus Plants

    PubMed Central

    Soliman, Sameh S. M.; Raizada, Manish N.

    2012-01-01

    Within a plant, there can exist an ecosystem of pathogens and endophytes, the latter described as bacterial and fungal inhabitants that thrive without causing disease to the host. Interactions between microbial inhabitants represent a novel area of study for natural products research. Here we analyzed the interactions between the fungal endophytes of Taxus (yew) trees. Fungal endophytes of Taxus have been proposed to produce the terpenoid secondary metabolite, Taxol, an anti-cancer drug. It is widely reported that plant extracts stimulate endophytic fungal Taxol production, but the underlying mechanism is not understood. Here, Taxus bark extracts stimulated fungal Taxol production 30-fold compared to a 10-fold induction with wood extracts. However, candidate plant-derived defense compounds (i.e., salicylic acid, benzoic acid) were found to act only as modest elicitors of fungal Taxol production from the endophytic fungus Paraconiothyrium SSM001, consistent with previous studies. We hypothesized the Taxus plant extracts may contain elicitors derived from other microbes inhabiting these tissues. We investigated the effects of co-culturing SSM001 with other fungi observed to inhabit Taxus bark, but not wood. Surprisingly, co-culture of SSM001 with a bark fungus (Alternaria) caused a ∼threefold increase in Taxol production. When SSM001 was pyramided with both the Alternaria endophyte along with another fungus (Phomopsis) observed to inhabit Taxus, there was an ∼eightfold increase in fungal Taxol production from SSM001. These results suggest that resident fungi within a host plant interact with one another to stimulate Taxol biosynthesis, either directly or through their metabolites. More generally, our results suggest that endophyte secondary metabolism should be studied in the context of its native ecosystem. PMID:23346084

  12. Role of metallic stents in benign esophageal stricture

    NASA Astrophysics Data System (ADS)

    Shim, Chan Sup

    2012-10-01

    Simple esophageal strictures, which are focal, straight, and large in diameter, usually require 1 - 3 dilation sessions to relieve symptoms. However, complex strictures, which are long, tortuous, or associated with a severely compromised luminal diameter, are usually more difficult to treat with conventional bougie or balloon dilation techniques, and often have high recurrence rates. Although the permanent placement of self-expandable metal stents (SEMS) has been used to manage refractory benign esophageal strictures, this procedure is associated with additional problems, such as stricture from tissue hyperplasia, stent migration, and fistula formation. Thus, several new types of stents have been developed, including temporary SEMS, self-expandable plastic stents (SEPS), and biodegradable stents. The use of these new products has produced varied results. Temporary SEMS that have been used to relieve benign esophageal conditions have caused granulation tissue at both ends of the stent because of contact between the mucosa and the exposed metal components of the stent, thus hindering stent removal. We examined the tissue response to two new types of SEMS, a flange-type and a straighttype, each coated with a silicone membrane on the outside of the metal mesh. These two SEMS were evaluated individually and compared with a conventional control stent in animal experiments. Although the newly designed stents resulted in reduced tissue hyperplasia, and were thus more easily separated from the esophageal tissue, some degree of tissue hyperplasia did occur. We suggest that newly designed DES (drug-eluting stents) may provide an alternative tool to manage refractory benign esophageal stricture.

  13. Carotid artery stenting: current and emerging options

    PubMed Central

    Morr, Simon; Lin, Ning; Siddiqui, Adnan H

    2014-01-01

    Carotid artery stenting technologies are rapidly evolving. Options for endovascular surgeons and interventionists who treat occlusive carotid disease continue to expand. We here present an update and overview of carotid stenting devices. Evidence supporting carotid stenting includes randomized controlled trials that compare endovascular stenting to open surgical endarterectomy. Carotid technologies addressed include the carotid stents themselves as well as adjunct neuroprotective devices. Aspects of stent technology include bare-metal versus covered stents, stent tapering, and free-cell area. Drug-eluting and cutting balloon indications are described. Embolization protection options and new direct carotid access strategies are reviewed. Adjunct technologies, such as intravascular ultrasound imaging and risk stratification algorithms, are discussed. Bare-metal and covered stents provide unique advantages and disadvantages. Stent tapering may allow for a more fitted contour to the caliber decrement between the common carotid and internal carotid arteries but also introduces new technical challenges. Studies regarding free-cell area are conflicting with respect to benefits and associated risk; clinical relevance of associated adverse effects associated with either type is unclear. Embolization protection strategies include distal filter protection and flow reversal. Though flow reversal was initially met with some skepticism, it has gained wider acceptance and may provide the advantage of not crossing the carotid lesion before protection is established. New direct carotid access techniques address difficult anatomy and incorporate sophisticated flow-reversal embolization protection techniques. Carotid stenting is a new and exciting field with rapidly advancing technologies. Embolization protection, low-risk deployment, and lesion assessment and stratification are active areas of research. Ample room remains for further innovations and developments. PMID:25349483

  14. Favorable effect of optimal lipid-lowering therapy on neointimal tissue characteristics after drug-eluting stent implantation: qualitative optical coherence tomographic analysis.

    PubMed

    Jang, Ji-Yong; Kim, Jung-Sun; Shin, Dong-Ho; Kim, Byeong-Keuk; Ko, Young-Guk; Choi, Donghoon; Jang, Yangsoo; Hong, Myeong-Ki

    2015-10-01

    Serial follow-up optical coherence tomography (OCT) was used to evaluate the effect of optimal lipid-lowering therapy on qualitative changes in neointimal tissue characteristics after drug-eluting stent (DES) implantation. DES-treated patients (n = 218) who received statin therapy were examined with serial follow-up OCT. First and second follow-up OCT evaluations were performed approximately 6 and 18 months after the index procedure, respectively. Patients were divided into two groups, based on the level of low-density lipoprotein-cholesterol (LDL-C), which was measured at the second follow-up. The optimal lipid-lowering group (n = 121) had an LDL-C reduction of ≥50% or an LDL-C level ≤70 mg/dL, and the conventional group (n = 97). Neointimal characteristics were qualitatively categorized as homogeneous or non-homogeneous patterns using OCT. The non-homogeneous group included heterogeneous, layered, or neoatherosclerosis patterns. Qualitative changes in neointimal tissue characteristics between the first and second follow-up OCT examinations were assessed. Between the first and second follow-up OCT procedures, the neointimal cross-sectional area increased more substantially in the conventional group (0.4 mm(2) vs. 0.2 mm(2) in the optimal lipid-lowering group, p = 0.01). The neointimal pattern changed from homogeneous to non-homogeneous less often in the optimal lipid-lowering group (1.3%, 1/77, p < 0.001) than in the conventional group (15.3%, 11/72, p = 0.44). Optimal LDL-C reduction was an independent predictor for the prevention of neointimal pattern change from homogeneous to non-homogeneous (odds ratio: 0.05, 95% confidence interval: 0.01∼0.46, p = 0.008). Our findings suggest that an intensive reduction in LDL-C levels can prevent non-homogeneous changes in the neointima and increases in neointimal cross-sectional area compared with conventional LDL-C controls. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  15. Local Delivery of Gene Vectors From Bare-Metal Stents by Use of a Biodegradable Synthetic Complex Inhibits In-Stent Restenosis in Rat Carotid Arteries

    PubMed Central

    Fishbein, Ilia; Alferiev, Ivan; Bakay, Marina; Stachelek, Stanley J.; Sobolewski, Peter; Lai, Meizan; Choi, Hoon; Chen, I.-W.; Levy, Robert J.

    2012-01-01

    Background Local drug delivery from polymer-coated stents has demonstrated efficacy for preventing in-stent restenosis; however, both the inflammatory effects of polymer coatings and concerns about late outcomes of drug-eluting stent use indicate the need to investigate innovative approaches, such as combining localized gene therapy with stent angioplasty. Thus, we investigated the hypothesis that adenoviral vectors (Ad) could be delivered from the bare-metal surfaces of stents with a synthetic complex for reversible vector binding. Methods and Results We synthesized the 3 components of a gene vector binding complex: (1) A polyallylamine bisphosphonate with latent thiol groups (PABT), (2) a polyethyleneimine (PEI) with pyridyldithio groups for amplification of attachment sites [PEI(PDT)], and (3) a bifunctional (amine- and thiol-reactive) cross-linker with a labile ester bond (HL). HL-modified Ad attached to PABT/PEI(PDT)-treated steel surfaces demonstrated both sustained release in vitro over 30 days and localized green fluorescent protein expression in rat arterial smooth muscle cell cultures, which were not sensitive to either inhibition by neutralizing anti-Ad antibodies or inactivation after storage at 37°C. In rat carotid studies, deployment of steel stents configured with PABT/PEI(PDT)/HL-tethered adenoviral vectors demonstrated both site-specific arterial AdGFP expression and adenovirus-luciferase transgene activity per optical imaging. Rat carotid stent delivery of adenovirus encoding inducible nitric oxide synthase resulted in significant inhibition of restenosis. Conclusions Reversible immobilization of adenovirus vectors on the bare-metal surfaces of endovascular stents via a synthetic complex represents an efficient, tunable method for sustained release of gene vectors to the vasculature. PMID:18413497

  16. A Finite Element Study on Variations in Mass Transport in Stented Porcine Coronary Arteries Based on Location in the Coronary Arterial Tree

    PubMed Central

    Keyes, Joseph T.; Simon, Bruce R.; Vande Geest, Jonathan P.

    2013-01-01

    Drug-eluting stents have a significant clinical advantage in late-stage restenosis due to the antiproliferative drug release. Understanding how drug transport occurs between coronary arterial locations can better help guide localized drug treatment options. Finite element models with properties from specific porcine coronary artery sections (left anterior descending (LAD), right (RCA); proximal, middle, distal regions) were created for stent deployment and drug delivery simulations. Stress, strain, pore fluid velocity, and drug concentrations were exported at different time points of simulation (0–180 days). Tests indicated that the highest stresses occurred in LAD sections. Higher-than-resting homeostatic levels of stress and strain existed at upwards of 3. mm away from the stented region, whereas concentration of species only reached 2.7 mm away from the stented region. Region-specific concentration showed 2.2 times higher concentrations in RCA artery sections at times corresponding to vascular remodeling (peak in the middle segment) compared to all other segments. These results suggest that wall transport can occur differently based on coronary artery location. Awareness of peak growth stimulators and where drug accumulation occurs in the vasculature can better help guide local drug delivery therapies. PMID:23699720

  17. Perioperative antiplatelet management in patients with coronary artery stenting.

    PubMed

    Tandar, Anwar; Velagapudi, Krishna N; Wilson, Brent D; Boden, William E

    2012-04-01

    Coronary artery disease is the primary cause of mortality in men and women in the United States. Transcatheter coronary intervention is the mainstay of treatment for patients with acute coronary artery disease presentations and patients with stable disease. Although percutaneous intervention initially only included balloon angioplasty, it now typically involves the placement of intracoronary stents. To overcome the limitations of bare-metal stents, namely in-stent restenosis, stents have been developed that remove pharmaceuticals that reduce neointimal hyperplasia and in-stent restenosis. However, these pharmaceutical agents also delay stent endothelialization, posing a prolonged risk of in situ thrombosis. Placement of an intracoronary stent (eg, bare-metal or drug-eluting stent) requires dual antiplatelet therapy to prevent the potentially life-threatening complication of stent thrombosis. The optimal duration of dual antiplatelet therapy following stent placement is unknown. This article discusses the factors to be considered when deciding when dual antiplatelet therapy can be safely discontinued. Unfortunately, in the hospital setting, this decision to interrupt dual antiplatelet therapy frequently must be made shortly after stent placement because of unanticipated surgical procedures or other unforeseen complications. The decision of when dual antiplatelet therapy can be safely interrupted needs to be individualized for each patient and involves factoring in the type of stent; the location and complexity of the lesion stented; post-stent lesion characteristics; the amount of time since stent placement; and the antiplatelet regimen currently in use, along with its implication for bleeding during the proposed procedure. Having a protocol in place, such as the protocol described in this article, can help guide this decision-making process and avoid confusion and potential error.

  18. Hemocompatibility Improvement of Chromium-Bearing Bare-Metal Stent Platform After Magnetoelectropolishing

    NASA Astrophysics Data System (ADS)

    Rokicki, Ryszard; Haider, Waseem; Maffi, Shivani Kaushal

    2015-01-01

    Research was undertaken to determine the influence of the increased content of chromium in the outermost passive layer of magneto-electrochemically refined Co-Cr alloy L-605 surface on its hemocompatibility. The chemistry, roughness, surface energy, and wettability of conventionally electropolished (EP) and magnetoelectropolished (MEP) samples were studied with x-ray photoelectron spectroscopy (XPS), open circuit potential, atomic force microscopy, and contact angle meter. In vitro hemocompatibility of tested material surfaces was assessed using two important indicators of vascular responses to biomaterial, namely endothelialization and platelets adhesion. The endothelialization was assessed by seeding and incubating samples with human umbilical vein endothelial cells (HUVEC) for 3 days before counting and observing them under a fluorescent microscope. The platelet (rich plasma blood) adhesion and activation test on EP and MEP L-605 alloy surfaces was assessed using a laser scanning confocal microscope. The XPS analysis of MEP samples showed significant enrichment of the passive layer with Cr and O when compared with the EP one. The amount of other elements in the passive layer did not show a significant difference between EP and MEP treatments. The adhesion of HUVEC cells shows remarkable affinity to surfaces enriched in Cr (MEP) with almost 100% confluency. In addition, the number of platelets that adhered to standard EP surfaces was higher compared to the MEP surface. The present study shows that the chromium-enriched surface of cobalt-chromium alloy L-605 by the magnetoelectropolishing process tremendously improves surface hemocompatibility with regard to stent functionality by enhanced endothelialization and lower platelet adhesion and should be taken under consideration as an alternative surface of biodegradable polymer drug-eluting stents, polymer-free drug-eluting stents as well as bare-metal stents.

  19. 1-year clinical outcomes of diabetic patients treated with everolimus-eluting bioresorbable vascular scaffolds: a pooled analysis of the ABSORB and the SPIRIT trials.

    PubMed

    Muramatsu, Takashi; Onuma, Yoshinobu; van Geuns, Robert-Jan; Chevalier, Bernard; Patel, Tejas M; Seth, Ashok; Diletti, Roberto; García-García, Hector M; Dorange, Cécile C; Veldhof, Susan; Cheong, Wai-Fung; Ozaki, Yukio; Whitbourn, Robert; Bartorelli, Antonio; Stone, Gregg W; Abizaid, Alexandre; Serruys, Patrick W

    2014-05-01

    The aim of this study was to evaluate 1-year clinical outcomes of diabetic patients treated with the Absorb bioresorbable vascular scaffold (BVS). Clinical outcomes of diabetic patients after BVS implantation have been unreported. This study included 101 patients in the ABSORB Cohort B trial and the first consecutive 450 patients with 1 year of follow-up in the ABSORB EXTEND trial. A total of 136 diabetic patients were compared with 415 nondiabetic patients. In addition, 882 diabetic patients treated with everolimus-eluting metal stents (EES) in pooled data from the SPIRIT trials (SPIRIT FIRST [Clinical Trial of the Abbott Vascular XIENCE V Everolimus Eluting Coronary Stent System], SPIRIT II [A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System], SPIRIT III [Clinical Trial of the XIENCE V Everolimus Eluting Coronary Stent System (EECSS)], SPIRIT IV Clinical Trial [Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System]) were used for the comparison by applying propensity score matching. The primary endpoint was a device-oriented composite endpoint (DoCE), including cardiac death, target vessel myocardial infarction, and target lesion revascularization at 1-year follow-up. The cumulative incidence of DoCE did not differ between diabetic and nondiabetic patients treated with the BVS (3.7% vs. 5.1%, p = 0.64). Diabetic patients treated with the BVS had a similar incidence of the DoCE compared with diabetic patients treated with EES in the matched study group (3.9% for the BVS vs. 6.4% for EES, p = 0.38). There were no differences in the incidence of definite or probable scaffold/stent thrombosis (0.7% for both diabetic and nondiabetic patients with the BVS; 1.0% for diabetic patients with the BVS vs. 1.7% for diabetic patients with EES in the matched study group). In the present analyses, diabetic patients treated with the BVS showed similar rates of DoCEs compared with nondiabetic patients treated with the BVS and

  20. Sex differences in the outcomes of stent implantation in mini-swine model.

    PubMed

    Kunio, Mie; Wong, Gee; Markham, Peter M; Edelman, Elazer R

    2018-01-01

    Sex-related differences have been noted in cardiovascular anatomy, pathophysiology, and treatment responses, yet we continued to drive evaluation of vascular device development in animal models without consideration of animal sex. We aimed to understand sex-related differences in the vascular responses to stent implantation by analyzing the pooled data of endovascular interventions in 164 Yucatan mini-swine (87 female, 77 male). Bare metal stents (BMS) or drug-eluting stents (DES) were implanted in 212 coronary arteries (63 single BMS implantation, 68 single DES implantation, 33 overlapped BMS implantation, and 48 overlapped DES implantation). Histomorphological parameters were evaluated from vascular specimens at 3-365 days after stent implantation and evaluated values were compared between female and male groups. While neointima formation at all times after implantation was invariant to sex, statistically significant differences between female and male groups were observed in injury, inflammation, adventitial fibrosis, and neointimal fibrin deposition. These differences were observed independently, i.e., for different procedure types and at different follow-up timings. Only subtle temporal sex-related differences were observed in extent and timing of resolution of inflammation and fibrin clearance. These subtle sex-related differences may be increasingly important as interventional devices meld novel materials that erode and innovations in drug delivery. Erodible materials may act differently if inflammation has a different temporal sequence with sex, and drug distribution after balloon or stent delivery might be different if the fibrin clearance speaks to different modes of pharmacokinetics in male and female swine.

  1. Rotational atherectomy before paclitaxel-eluting stent implantation in complex calcified coronary lesions: Two-year clinical outcome of the randomized ROTAXUS trial.

    PubMed

    de Waha, Suzanne; Allali, Abdelhakim; Büttner, Heinz-Joachim; Toelg, Ralph; Geist, Volker; Neumann, Franz-Josef; Khattab, Ahmed A; Richardt, Gert; Abdel-Wahab, Mohamed

    2016-03-01

    In the randomized ROTAXUS trial, routine lesion preparation of complex calcified coronary lesions using rotational atherectomy (RA) prior to paclitaxel-eluting stent implantation did not reduce the primary endpoint of angiographic late lumen loss at 9 months compared to stenting without RA. So far, no long-term data of prospective head-to-head comparisons between both treatment strategies have been reported. ROTAXUS randomly assigned patients with complex calcified coronary lesions to RA followed by stenting (n = 120) or stenting without RA (n = 120). The primary endpoint of the current analysis was the occurrence of major adverse cardiac events (MACE) at 2-year follow-up defined as the composite of death, myocardial infarction, and target vessel revascularization (TVR). At 2 years, MACE occurred in 32 patients in the RA group and 37 patients in the standard therapy group (29.4% vs. 34.3%, P = 0.47). The rates of death (8.3% vs. 7.4%, P = 1.00), myocardial infarction (8.3% vs. 6.5%, P = 0.80), target lesion revascularization (TLR, 13.8% vs. 16.7%, P = 0.58), and TVR (19.3% vs. 22.2%, P = 0.62) were similar in both groups. Despite high rates of initial angiographic success, nearly one third of patients enrolled in ROTAXUS experienced MACE within 2-year follow-up, with no differences between patients treated with or without RA. © 2015 Wiley Periodicals, Inc.

  2. Efficacy and safety of a biodegradable polymer Cobalt-Chromium sirolimus-eluting stent (EXCEL2) in treating de novo coronary artery disease: A pooled analysis of the CREDIT II and CREDIT III trials.

    PubMed

    Wang, Geng; Wang, Heyang; Xu, Bo; Yang, Yuejin; Yang, Zhiming; Li, Hui; Zhang, Zheng; Wang, Haichang; Yang, Lixia; Han, Yaling

    2017-03-01

    The safety and efficacy of the second-generation biodegradable polymer Cobalt-Chromium sirolimus-eluting stent (EXCEL2) in daily clinical practice remains unknown. Additionally, to meet the China Food and Drug Administration requirements, we conducted an objective performance criterion study from the CREDIT II and CREDIT III trials. CREDIT II was a randomized trial comparing the EXCEL2 versus EXCEL stent in patients with up to 2 de novo coronary lesions. CREDIT III was a prospective, single-arm study evaluating the efficacy and safety of EXCEL2 in broad types of de novo coronary artery lesions. This pooled analysis included patients in the CREDIT III and EXCEL2 arm of the CREDIT II trial. The primary outcome was 12-month target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction (TV-MI), and clinical indicated target lesion revascularization (CI-TLR). The patient-oriented composite endpoint (PoCE) of all-cause death, all MI, or any revascularization was also analyzed. A total of 833 patients were included, consisting of 625 in the CREDIT III trial and 208 in the EXCEL2 arm of the CREDIT II trial. Twelve-month TLF occurred in 6.1% patients, cardiac death in 0.4%, TV-MI in 5%, and CI-TLR in 1.1%. Additionally, 64 (7.7%) PoCE and 3 probable late stent thromboses (0.4%) were recorded. EXCEL2 stent met the objective performance criterion on efficacy and safety with a low level of 12-month TLF as well as stent thrombosis when treating patients with de novo coronary lesions. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  3. Efficacy of a Multiplex Paclitaxel Emission Stent Using a Pluronic® Mixture Membrane versus a Covered Metal Stent in Malignant Biliary Obstruction: A Prospective Randomized Comparative Study.

    PubMed

    Jang, Sung Ill; Lee, Se Joon; Jeong, Seok; Lee, Don Haeng; Kim, Myung-Hwan; Yoon, Hong Jin; Lee, Dong Ki

    2017-07-15

    A drug-eluting stent for unresectable malignant biliary obstruction was developed to increase stent patency by preventing tumor ingrowth. The safety and efficacy of a new generation of metallic stents covered with a paclitaxel-incorporated membrane using a Pluronic ® mixture (MSCPM-II) were compared prospectively with those of covered metal stents (CMSs) in patients with malignant biliary obstructions. This study was initially designed as a prospective randomized trial but was closed early because of a high incidence of early occlusion. Therefore, the data were analyzed using the intent-to-treat method. A total of 72 patients with unresectable distal malignant biliary obstructions were prospectively enrolled. The two groups did not differ significantly in basic characteristics and mean follow-up period (MSCPM-II 194 days vs CMS 277 days, p=0.063). Stent occlusion occurred in 14 patients (35%) who received MSCPM-II and in seven patients (21.9%) who received CMSs. Stent patency and survival time did not significantly differ between the two groups (p=0.355 and p=0.570). The complications were mild and resolved by conservative management in both groups. There were no significant differences in stent patency or patient survival in MSCPM-II and CMS patients with malignant biliary obstructions.

  4. Quantitative optical coherence tomography analysis for late in-stent restenotic lesions.

    PubMed

    Fu, Qiang; Suzuki, Nobuaki; Kozuma, Ken; Miyagawa, Mutsuki; Nomura, Takahiro; Kawashima, Hideyuki; Shiratori, Yoshitaka; Ishikawa, Shuichi; Kyono, Hiroyuki; Isshiki, Takaaki

    2015-01-01

    Coronary optical coherence tomography (OCT) has the potential to identify in-stent neoatherosclerosis, which is a possible risk factor for late acute coronary events after drug-eluting stent implantation. The purpose of this study was to investigate differences between mid-term and late in-stent restenosis after stent implantation by quantitative and semiautomated tissue property analysis using OCT. In total, 1063 OCT image frames of 16 lesions in 15 patients were analyzed. This included 346 frames of 6 lesions in late in-stent restenosis, which was defined as restenosis that was not detected at 6 to 12 months but ≥ 12 months after follow-up coronary angiography. Signal attenuation was circumferentially analyzed using a dedicated semiautomated software. Attenuation was assessed along 200 lines delineated radially for analysis of the in-stent restenotic lesions (between the lumen and stent contours). All lines were anchored by the image wire to avoid artifacts resulting from wire location. Stronger signal attenuation at the frame level (2.46 ± 0.78 versus 1.47 ± 0.32, P < 0.001) and higher maximum signal intensity at the lesion level (9.19 ± 0.19 versus 8.84 ± 0.32, P = 0.018) were observed in late in-stent restenotic lesions than in mid-term in-stent restenotic lesions. OCT demonstrated stronger signal attenuation and higher maximum signal intensity in late in-stent restenotic lesions than in mid-term in-stent restenotic lesions, indicating the possibility of neoatherosclerosis.

  5. Drug-Eluting Stents: Do They Increase Heart Attack Risk?

    MedlinePlus

    ... nitrates or calcium channel blockers, as well as aspirin and cholesterol-lowering drugs called statins. With medications, ... doctor will likely also prescribe medications, such as aspirin and statins, and lifestyle changes. Angioplasty and bare- ...

  6. Optical Coherence Tomography Substudy of A Prospective Multicenter Randomized Post-Market Trial to Assess the Safety and Effectiveness of the Firehawk™ Rapamycin Target Eluting Cobalt Chromium Coronary Stent System for the Treatment of Atherosclerotic Lesions: TARGET All Comers.

    PubMed

    Baumbach, Andreas; Lansky, Alexandra J; Onuma, Yoshi; Asano, Taku; Johnson, Thomas; Anderson, Richard; Kiemeneij, Ferdinand; Zheng, Ming; Van Royen, Niels; Slagboom, Ton; Vlachojannis, Georg; Xu, Bo; Serruys, Patrick; Wijns, William

    2018-06-12

    Durable polymer drug-eluting stents (DP DES) may contribute to persistent inflammation, delayed endothelial healing and subsequent late DES thrombosis. The aim of this Optical Coherence Tomography (OCT) sub-study was to compare healing and neointimal coverage of a novel bioabsorbable polymer sirolimus-eluting stent (FIREHAWK®) (BP DES) versus the DP DES (XIENCE) at 90 days in an all comers patient population. The TARGET All Comers study is a prospective multicenter randomised post-market trial of 1656 patients randomised 1:1 to FIREHAWK or XIENCE at 21 centers in 10 European countries. The TARGET OCT sub-study enrolled 36 consecutive patients with 52 lesions at 6 centers proficient in OCT. Follow-up OCT was performed at 3 months or prior to revascularisation when occurring before the 3-month window. The substudy was designed for non-inferiority of the primary endpoint of neointimal thickness. At follow-up, the mean neointimal thickness by OCT (52 lesions, Firehawk, n=24; Xience, n=28), was not significantly different between groups (Firehawk 75.5μm vs Xience V 82.3 μm) meeting the primary endpoint of non-inferiority (Pnoninferiority<0.001). The percentage of stent strut coverage was high in both groups (strut level: 99.9% ± 0.3 vs 100% ± 0.1, p=0.26), and the proportion of malapposed struts (1.0±1.6% vs. 1.2±2.0%, p=0.51) was low in both groups. Based on OCT, the FIREHAWK BP DES has a similar healing response 3 months after implantation compared to the DP DES, with near complete strut coverage, moderate neointima formation and minimal strut malapposition.

  7. Macro- and microscale variables regulate stent haemodynamics, fibrin deposition and thrombomodulin expression

    PubMed Central

    Jiménez, Juan M.; Prasad, Varesh; Yu, Michael D.; Kampmeyer, Christopher P.; Kaakour, Abdul-Hadi; Wang, Pei-Jiang; Maloney, Sean F.; Wright, Nathan; Johnston, Ian; Jiang, Yi-Zhou; Davies, Peter F.

    2014-01-01

    Drug eluting stents are associated with late stent thrombosis (LST), delayed healing and prolonged exposure of stent struts to blood flow. Using macroscale disturbed and undisturbed fluid flow waveforms, we numerically and experimentally determined the effects of microscale model strut geometries upon the generation of prothrombotic conditions that are mediated by flow perturbations. Rectangular cross-sectional stent strut geometries of varying heights and corresponding streamlined versions were studied in the presence of disturbed and undisturbed bulk fluid flow. Numerical simulations and particle flow visualization experiments demonstrated that the interaction of bulk fluid flow and stent struts regulated the generation, size and dynamics of the peristrut flow recirculation zones. In the absence of endothelial cells, deposition of thrombin-generated fibrin occurred primarily in the recirculation zones. When endothelium was present, peristrut expression of anticoagulant thrombomodulin (TM) was dependent on strut height and geometry. Thinner and streamlined strut geometries reduced peristrut flow recirculation zones decreasing prothrombotic fibrin deposition and increasing endothelial anticoagulant TM expression. The studies define physical and functional consequences of macro- and microscale variables that relate to thrombogenicity associated with the most current stent designs, and particularly to LST. PMID:24554575

  8. Impact of stent diameter and length on in-stent restenosis after DES vs BMS implantation in patients needing large coronary stents-A clinical and health-economic evaluation.

    PubMed

    Zbinden, Rainer; von Felten, Stefanie; Wein, Bastian; Tueller, David; Kurz, David J; Reho, Ivano; Galatius, Soren; Alber, Hannes; Conen, David; Pfisterer, Matthias; Kaiser, Christoph; Eberli, Franz R

    2017-02-01

    The British National Institute of Clinical Excellence (NICE) guidelines recommend to use drug-eluting stents (DES) instead of bare-metal stents (BMS) only in lesions >15 mm in length or in vessels <3 mm in diameter. We analyzed the impact of stent length and stent diameter on in-stent restenosis (ISR) in the BASKET-PROVE study population and evaluated the cost-effectiveness of DES compared to BMS. The BASKET-PROVE trial compared DES vs BMS in large coronary arteries (≥3 mm). We calculated incremental cost-effectiveness ratios (ICERs) and cost-effectiveness acceptability curves with regard to quality-adjusted life years (QALYs) gained and target lesion revascularizations (TLRs) avoided. A total of 2278 patients were included in the analysis. A total of 74 ISR in 63 patients were observed. In-stent restenosis was significantly more frequent in segments treated with a BMS compared to segments treated with a DES (5.4% vs 0.76%; P<.001). The benefit of a DES compared to a BMS regarding ISR was consistent among the subgroups of stent length >15 mm and ≤15 mm, respectively. With the use of DES in short lesions, there was only a minimal gain of 0.005 in QALYs. At a threshold of 10 000 CHF per TLR avoided, DES had a high probability of being cost-effective. In the BASKET-PROVE study population, the strongest predictor of ISR is the use of a BMS, even in patients in need of stents ≥3.0 mm and ≤15 mm lesion length and DES were cost-effective. This should prompt the NICE to reevaluate its recommendation to use DES instead of BMS only in vessels <3.0 mm and lesions >15 mm length. © 2016 John Wiley & Sons Ltd.

  9. The relationship between post-stent strut apposition and follow-up strut coverage assessed by a contour plot optical coherence tomography analysis.

    PubMed

    Kim, Jung-Sun; Ha, Jinyong; Kim, Byeong-Keuk; Shin, Dong-Ho; Ko, Young-Guk; Choi, Donghoon; Jang, Yangsoo; Hong, Myeong-Ki

    2014-06-01

    Dyslipidemia and Hypertension and the Types of Implanted Drug-Eluting Stents; NCT01502904). Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  10. Biodegradable tocopherol acetate as a drug carrier to prevent ureteral stent-associated infection.

    PubMed

    Elayarajah; Rajendran, R; Venkatrajah; Sreekumar, Sweda; Sudhakar, Asa; Janiga; Sreekumar, Soumya

    2011-03-01

    Biomaterial-centred bacterial infections present common and challenging complications with medical implants like ureteral stent which provide substratum for the biofilm formation. Hence the purpose of this study is to make antibacterial stent surface with biodegradable polymer (tocopherol acetate) and anti-infective agents (norfloxacin and metronidazole) using a modified dip-coating procedure. This is done by impregnating the stent pieces in the anti-infective solution (a mixture of norfloxacin-metronidazole and polymer) for uniform surface coating (drug-carrier-coated stents). After coating, agar diffusion test was performed as qualitative test to find out the sensitivity of coated stents against the clinical isolates, Staphylococcus epidermidis and Escherichia coli. Quantitative test was measured by calculating the numbers of adhered bacteria on coated and uncoated stents by incubating the stent pieces in artificial urine. Difference in the number of viable bacteria adhered on the surface of coated and uncoated stents were statistically calculated using chi square test with p < 0.05 considered significant. The stent colonising ability of Staphylococcus epidermidis and Escherichia coli in a controlled environment chamber was determined using two-challenge dose of the isolates by in vitro challenge test. In qualitative test, the zone of inhibition around the coated stents showed sensitivity against the clinical isolates. In quantitative test, the number of adhered bacteria on the surface of coated stents was reduced to a significant level (p < 0.05). The polymer, tocopherol acetate is highly biodegradable in nature. Due to its degrading ability in body tissues, it releases the anti-infective drugs at a constant and sustained rate.

  11. A prospective randomised trial comparing the novel ridaforolimus-eluting BioNIR stent to the zotarolimus-eluting Resolute stent: six-month angiographic and one-year clinical results of the NIREUS trial.

    PubMed

    Paradies, Valeria; Ben-Yehuda, Ori; Jonas, Michael; Banai, Shmuel; Iñiguez, Andres; Perlman, Gidon Y; Kandzari, David E; Stone, Gregg W; Smits, Pieter C

    2018-05-20

    The aim of this study was to evaluate the efficacy and safety of the BioNIR stent compared with the Resolute Integrity stent for the treatment of coronary artery disease. This first-in-human, multicentre, single-blind randomised non-inferiority trial was performed in Europe and Israel. Patients with stable coronary artery disease or acute coronary syndromes were randomly assigned to treatment with BioNIR or Resolute Integrity stents in a 2:1 fashion. The primary endpoint was angiographic in-stent late lumen loss (LLL) at six months. Three hundred and two patients were randomised, of whom 261 (86.0%) underwent six-month angiographic follow-up. The BioNIR stent was non-inferior to the Resolute Integrity stent for the primary endpoint of in-stent LLL at six months (0.04±0.30 mm vs. 0.03±0.31 mm, respectively, pnoninferiority<0.0001). At 12-month follow-up, target lesion failure occurred in 3.4% in the BioNIR group and 5.9% in the Resolute Integrity group (p=0.22). Rates of MACE were similar between the BioNIR and Resolute Integrity groups (4.3% vs. 5.9%, respectively, p=0.45). The BioNIR stent was non-inferior to the Resolute Integrity stent for the primary endpoint of angiographic in-stent LLL at six months. Clinical outcomes at one year were comparable between the two groups.

  12. Bioabsorbable coronary stents--are these the next big thing in coronary angioplasty?

    PubMed

    Balla, Sudarshan; Aggarwal, Kul; Nistala, Ravi

    2010-06-01

    The role of percutaneous coronary intervention (PCI) in the treatment of coronary artery disease has grown at an astronomical pace. Drug eluting stents (DES) offer advantages over bare metal stents (BMS) such as reduction in early in-stent restenosis rates. However, they have disadvantages like from increased late stent thrombosis when compared with BMS. Furthermore, recent data suggest endothelial dysfunction in the DES stented segments of the arteries. Currently, bioabsorbable stents are under development to avert the complications of DES such as stent thrombosis via degradation of the stent over time. The hypothetical advantage of leaving behind a natural vessel and restoring vasoreactivity may be the almost normal physiology which can be achieved after an intervention with a stent. The ABSORB and the PROGRESS AMS are two of the recent clinical trials that have looked at the outcomes of using bioabsorbable stents. So far, data from these and other studies has yielded mixed results in terms of angiographic and clinical outcomes. Newer stents such as REVA and WHISPER are presently being tested in preclinical and clinical trials. The landscape for bioabsorbable stents is constantly evolving through continued improvisation on existing technology and emergence of new technology. Large scale randomized trials are still needed with adequate long term follow-up for safety and benefits to have mainstream application in coronary artery disease, bioabsorbable stents are a promising innovation in the field of PCI. We review some of the patents and the data that is emerging on bioabsorbable stents in addition to currently ongoing clinical trials.

  13. Fluorocopolymer-coated nitinol self-expanding paclitaxel-eluting stent: pharmacokinetics and vascular biology responses in a porcine iliofemoral model.

    PubMed

    Hou, Dongming; Huibregtse, Barbara A; Eppihimer, Michael; Stoffregen, William; Kocur, Gordon; Hitzman, Cory; Stejskal, Elizabeth; Heil, John; Dawkins, Keith D

    2016-08-20

    Our aim was to evaluate arterial responses to paclitaxel and a novel fluorocopolymer-coated nitinol low-dose paclitaxel-eluting stent (FP-PES). Human smooth muscle cell (SMC) migration was assessed after exposure to paclitaxel in vitro. For pharmacokinetics and vascular response, FP-PES or bare metal stents (BMS) were implanted in porcine iliofemoral arteries. Paclitaxel significantly inhibited human coronary and femoral artery SMC migration at doses as low as 1 pM. Inhibition was significantly greater for femoral compared with coronary artery SMCs from 1 pM to 1 μM. Pharmacokinetics showed consistent paclitaxel release from FP-PES over the study duration. The peak arterial wall paclitaxel level was 3.7 ng/mg at 10 days, with levels decreasing to 50% of peak at 60 days and 10% at 180 days. Paclitaxel was not detected in blood or remote organs. Arteriogram and histomorphometry analyses showed FP-PES significantly inhibits neointimal proliferation versus BMS at 30 and 90 days. Re-endothelialisation scores were not different between groups. Paclitaxel affected femoral artery SMC migration at lower concentrations and to a greater degree than it did coronary artery SMCs. The novel FP-PES used in this preclinical study demonstrated a vascular healing response similar to BMS, while significantly inhibiting neointimal formation up to 90 days.

  14. Revascularisation versus medical treatment in patients with stable coronary artery disease: network meta-analysis

    PubMed Central

    Stortecky, Stefan; Stefanini, Giulio G; daCosta, Bruno R; Rutjes, Anne Wilhelmina; Di Nisio, Marcello; Siletta, Maria G; Maione, Ausilia; Alfonso, Fernando; Clemmensen, Peter M; Collet, Jean-Philippe; Cremer, Jochen; Falk, Volkmar; Filippatos, Gerasimos; Hamm, Christian; Head, Stuart; Kappetein, Arie Pieter; Kastrati, Adnan; Knuuti, Juhani; Landmesser, Ulf; Laufer, Günther; Neumann, Franz-Joseph; Richter, Dimitri; Schauerte, Patrick; Sousa Uva, Miguel; Taggart, David P; Torracca, Lucia; Valgimigli, Marco; Wijns, William; Witkowski, Adam; Kolh, Philippe; Juni, Peter

    2014-01-01

    Objective To investigate whether revascularisation improves prognosis compared with medical treatment among patients with stable coronary artery disease. Design Bayesian network meta-analyses to combine direct within trial comparisons between treatments with indirect evidence from other trials while maintaining randomisation. Eligibility criteria for selecting studies A strategy of initial medical treatment compared with revascularisation by coronary artery bypass grafting or Food and Drug Administration approved techniques for percutaneous revascularization: balloon angioplasty, bare metal stent, early generation paclitaxel eluting stent, sirolimus eluting stent, and zotarolimus eluting (Endeavor) stent, and new generation everolimus eluting stent, and zotarolimus eluting (Resolute) stent among patients with stable coronary artery disease. Data sources Medline and Embase from 1980 to 2013 for randomised trials comparing medical treatment with revascularisation. Main outcome measure All cause mortality. Results 100 trials in 93 553 patients with 262 090 patient years of follow-up were included. Coronary artery bypass grafting was associated with a survival benefit (rate ratio 0.80, 95% credibility interval 0.70 to 0.91) compared with medical treatment. New generation drug eluting stents (everolimus: 0.75, 0.59 to 0.96; zotarolimus (Resolute): 0.65, 0.42 to 1.00) but not balloon angioplasty (0.85, 0.68 to 1.04), bare metal stents (0.92, 0.79 to 1.05), or early generation drug eluting stents (paclitaxel: 0.92, 0.75 to 1.12; sirolimus: 0.91, 0.75 to 1.10; zotarolimus (Endeavor): 0.88, 0.69 to 1.10) were associated with improved survival compared with medical treatment. Coronary artery bypass grafting reduced the risk of myocardial infarction compared with medical treatment (0.79, 0.63 to 0.99), and everolimus eluting stents showed a trend towards a reduced risk of myocardial infarction (0.75, 0.55 to 1.01). The risk of subsequent revascularisation was noticeably

  15. Safety and efficacy of polymer-free biolimus-eluting stents in all-comer patients: the RUDI-FREE study.

    PubMed

    Sardella, Gennaro; Stefanini, Giulio G; Briguori, Carlo; Tamburino, Corrado; Fabbiocchi, Franco; Rotolo, Francesco; Tomai, Fabrizio; Paggi, Anita; Lombardi, Mario; Gioffrè, Gaetano; Sclafani, Rocco; Rolandi, Andrea; Sciahbasi, Alessandro; Scardaci, Francesco; Signore, Nicola; Calcagno, Simone; Mancone, Massimo; Chiarito, Mauro; Giordano, Arturo

    2018-05-21

    Polymer-free biolimus-eluting stents (PF-BES) have been shown superior to bare metal stents in high bleeding risk (HBR) patients treated with 1-month dual antiplatelet therapy (DAPT). However, limited evidence is available on PF-BES in non-HBR patients. We aim to evaluate the safety and efficacy of PF-BES in all-comer patients undergoing percutaneous coronary interventions (PCI). Patients with stable coronary artery disease or acute coronary syndromes (ACS) undergoing PCI with PF-BES in routine clinical practice were included in a multicenter, prospective registry. DAPT duration was left at the discretion of the operator. The primary endpoint was the composite of cardiovascular death, myocardial infarction (MI), and definite/probable stent thrombosis (ST) at 1 year. Overall, 1,104 consecutive patients treated with PF-BES were included at 16 Italian centers. Mean age was 68.7±11.2 years, 77.2% of patients were men, 30% had diabetes, 15.1% had chronic kidney disease, and 40.5% had ACS at baseline. Mean CRUSADE score was 24.1±13.1, and 83.7% of patients did not have high bleeding risk features. At 1-year, the primary endpoint occurred in 4.1% of patients, cardiovascular death in 2.4%, MI in 1.8%, and definite/probable ST in 1.1%. With respect to efficacy, target-lesion revascularization occurred in 1.2% of patients. This is the first study providing clinical evidence on the use of PF-BES in all-comer patients irrespective of HBR status. Our findings suggest that PF-BES has a favorable safety and efficacy profile in a real world clinical setting. Further investigation in randomised clinical trials against new-generation DES is warranted.

  16. Final five-year clinical outcomes in the EVOLVE trial: a randomised evaluation of a novel bioabsorbable polymer-coated, everolimus-eluting stent.

    PubMed

    Meredith, Ian T; Verheye, Stefan; Dubois, Christophe; Dens, Joseph; Farah, Bruno; Carrié, Didier; Walsh, Simon; Oldroyd, Keith; Varenne, Olivier; El-Jack, Seif; Moreno, Raul; Christen, Thomas; Allocco, Dominic J

    2018-04-20

    Long-term data on bioabsorbable polymer-coated everolimus-eluting stents (BP-EES) are limited. The EVOLVE trial compared the safety and efficacy of two dose formulations of the SYNERGY BP-EES with the permanent polymer-coated PROMUS Element EES (PE). The EVOLVE study was a prospective, multicentre, non-inferiority trial that randomised 291 patients with de novo coronary lesions (length: ≤28 mm; diameter: ≥2.25 to ≤3.5 mm) to receive PE (n=98), SYNERGY (n=94), or SYNERGY half-dose (n=99). At five years, there were no significant differences in the rates of TLF or individual components between groups. TLR rates trended lower in both SYNERGY arms than in the PE arm (TLR: 1.1% SYNERGY and 1.0% SYNERGY half-dose vs. 6.1% PE; p=0.07 and p=0.06, respectively). TVR was numerically lower in the SYNERGY arms compared to the PE arm (TVR: 3.3% SYNERGY and 4.2% SYNERGY half-dose vs. 10.2% PE; p=0.06 and p=0.11, respectively). No incidence of stent thrombosis was reported in any arm up to five years. The EVOLVE trial represents the longest-term follow-up of the SYNERGY stent available to date, demonstrating its continued safety and efficacy for the treatment of selected de novo atherosclerotic lesions up to five years.

  17. Real-world use of the second-generation cobalt-chromium sirolimus-eluting stents: 12-month results from the prospective multicentre FOCUS registry.

    PubMed

    Zhang, Feng; Ge, Junbo; Qian, Juying; Ge, Lei; Zhou, Jun

    2012-12-20

    The FOCUS registry is a prospective, multicentre, web-based programme designed to collect clinical outcome data from real-world patients receiving the second-generation cobalt-chromium sirolimus-eluting stent (CoCr-SES). From March 2009 to February 2010, a total of 5,084 patients from 83 centres who were eligible to receive CoCr-SES were enrolled in the FOCUS registry. The primary endpoint was 12-month major adverse cardiac events (MACE, defined as the composite of cardiac death, myocardial infarction [MI], and target vessel revascularisation [TVR]). One-year data were available for 5,013 (98.6%) of the 5,084 patients enrolled. The primary endpoint occurred in 174 (3.47%) of 5,013 patients, consisting of 43 (0.86%) cardiac deaths, 132 (2.63%) MI, and 46 (0.92%) TVR. According to the Academic Research Consortium definition, definite and probable stent thrombosis (ST) occurred in 0.52% (26/5,013) of patients, including 19 cases of early ST and 7 of late ST. The 12-month MACE rates were 3.73% and 2.60% for extended-use and standard-use patients, respectively (p=0.065). The second-generation CoCr-SES was associated with low rates of 12-month MACE and ST in a broad spectrum of patients, thereby confirming the clinical safety and efficacy of this stent in a real-world setting.

  18. Enhancement of endothelialisation of coronary stents by laser surface engineering.

    PubMed

    Li, Lin; Mirhosseini, Nazanin; Michael, Alun; Liu, Zhu; Wang, Tao

    2013-11-01

    Coronary stents have been widely used in the treatment of coronary heart disease. However, complications have hampered the long-term success of the device. Bare-metal stents (BMS) have a high rate of restenosis and poor endothelialisation. The drug-eluting stents (DES), although dramatically reduce restenosis, significantly prevent endothelialisation leading to late thrombosis and behave the same way as BMS after drug releasing. Rapid adhesion and growth of endothelial cells on the stent surface is a key process for early vascular healing after coronary stenting which contributes to the reduction of major complications. Surface properties manipulate cell growth and directly determine the success and life-span of the implants. However, the ideal surface properties of coronary stents are not yet fully understood. The objective of this research is to understand how surface micro/nano textures and associated material chemistry changes generated by a laser beam affect the behavior of endothelial cells on bare metal 316L stents. A high power laser beam was applied to modifying the surface properties of 316L coronary stent material and the commercial coronary stents, followed by examination of the adhesion and proliferation of human coronary endothelial cells that were growing on the surfaces. Surface properties were examined by scanning electron microscopy, contact angle measurement, and X-ray photoelectron spectroscopy. A novel surface with combined micro/nano features was created on stent material 316L and coronary stent with a specific surface chemistry. This surface gives rise to a threefold increase in the adhesion and eightfold increase in the proliferation of endothelial cells. Interestingly, such effects were only observed when the surface texture was produced in the nitrogen atmosphere suggesting the importance of the surface chemistry, including the dramatic increase of chromium nitride, for the interaction of endothelial cells with the material surface. This

  19. Nanomedicine for the reduction of the thrombogenicity of stent coatings

    PubMed Central

    Karagkiozaki, Varvara C; Logothetidis, Stergios D; Kassavetis, Spyridon N; Giannoglou, George D

    2010-01-01

    The treatment of patients with drug-eluting stents (DES) continues to evolve with the current emergence of DES technology that offers a combination of pharmacological and mechanical approaches to prevent arterial restenosis. However, despite the promising short-term and mid-term outcomes of DES, there are valid concerns about adverse clinical effects of late stent thrombosis. In this study, we present an example of how nanomedicine can offer solutions for improving stent coating manufacturing, by producing nanomaterials with tailored and controllable properties. The study is based on the exploitation of human platelets response towards carbon-based nanocoatings via atomic force microscope (AFM). AFM can facilitate the comprehensive analysis of platelets behavior onto stent nanocoatings and enable the study of thrombogenicity. Platelet-rich plasma from healthy donors was used for the real-time study of biointerfacial interactions. The carbon nanomaterials were developed by rf magnetron sputtering technique under controllable deposition conditions to provide favorable surface nanotopography. It was shown that by altering the surface topography of nanocoatings, the activation of platelets can be affected, while the carbon nanocoatings having higher surface roughness were found to be less thrombogenic in terms of platelets adhesion. This is an actual solution for improving the stent coating fabrication. PMID:20463940

  20. Structural Evaluation of Radially Expandable Cardiovascular Stents Encased in a Polyurethane Film

    NASA Technical Reports Server (NTRS)

    Trigwell, Steve; De, Samiran; Sharma, Rajesh; Mazumder, Malay K.; Mehta, Jawahar L.

    2004-01-01

    A method of encasing cardiovascular stents with an expandable polyurethane coating has been developed to provide a smooth homogeneous inner wall allowing for a confluent growth of endothelial cells. In this design, the metal wire stent structure is completely covered by the polyurethane film minimizing biocorrosion of the metal (stainless steel or nitinol), and providing a homogeneous surface for surface treatment and incorporation of various eluting drugs to prevent platelet aggregation while supporting endothelialization. The polyurethane surface was treated with a helium plasma for sterilization and promotes growth of cells. The paper details the performance of the coated film to expand with the metal stent up to 225 % during deployment. We present stress/strain behavior of polyurethane films, and subsequent plasma treatment of the surface and the adhesion of the coating to the stent structure upon expansion. A film of less than 25 tm was found to be sufficient for corrosion resistance and flexibility without producing any excess stress on the stent structure. Straining the film to 225 % and plasma modification did not affect the mechanical and surface properties while allowing for improved biocompatibility as determined by the critical surface tension, surface chemistry, and roughness.

  1. Prevalence, Management, and Long-Term (6-Year) Outcomes of Atrial Fibrillation Among Patients Receiving Drug-Eluting Coronary Stents.

    PubMed

    Choi, Hyo-In; Ahn, Jung-Min; Kang, Se Hun; Lee, Pil Hyung; Kang, Soo-Jin; Lee, Seung-Whan; Kim, Young-Hak; Lee, Cheol Whan; Park, Seong-Wook; Park, Duk-Woo; Park, Seung-Jung

    2017-06-12

    This study sought to investigate the incidence, management, and clinical relevance of atrial fibrillation (AF) during and after percutaneous coronary intervention (PCI) with drug-eluting stents (DES) and evaluate outcomes of different antithrombotic strategies. Uncertainty exists regarding the optimal antithrombotic strategy in patients with AF who are undergoing PCI with DES. Using a consecutive series of 10,027 patients who underwent DES implantation between 2003 and 2011, we evaluated the overall prevalence and clinical impact of AF. In addition, we compared the efficacy and safety of dual antiplatelet therapy (DAPT) (aspirin plus clopidogrel) and triple therapy (DAPT plus warfarin) among patients with AF. The primary outcome was a composite of cardiovascular death, myocardial infarction, or stroke. Overall, 711 (7.1%) patients had a diagnosis of AF at the index PCI. Patients with AF were older, had more comorbid conditions, and more often had a history of strokes; most patients with AF (88.4%) received DAPT rather than triple therapy (10.5%) at discharge. The rate of primary outcome after PCI during the 6-year follow-up period was significantly higher in patients with AF than in those without AF (22.1% vs. 8.0%; p < 0.001). This trend was consistent for major bleeding (4.5% vs. 1.5%; p < 0.001). After multivariable adjustment, the presence of AF was significantly associated with a higher risk of primary outcome (hazard ratio [HR]: 2.33; 95% confidence interval [CI]: 1.95 to 2.79; p < 0.001) and major bleeding (HR: 2.01; 95% CI: 1.32 to 3.06; p = 0.001). Among patients with AF, adjusted risk for the primary outcome was similar between the DAPT group and the triple therapy group (HR: 1.01; 95% CI: 0.60 to 1.69; p = 0.98), but triple therapy was associated with a significantly higher risk of hemorrhagic stroke (HR: 7.73; 95% CI: 2.14 to 27.91; p = 0.002) and major bleeding (HR: 4.48; 95% CI: 1.81 to 11.08; p = 0.001). Among patients receiving DES

  2. Fabrication and in vitro deployment of a laser-activated shape memory polymer vascular stent

    PubMed Central

    Baer, Géraldine M; Small, Ward; Wilson, Thomas S; Benett, William J; Matthews, Dennis L; Hartman, Jonathan; Maitland, Duncan J

    2007-01-01

    Background Vascular stents are small tubular scaffolds used in the treatment of arterial stenosis (narrowing of the vessel). Most vascular stents are metallic and are deployed either by balloon expansion or by self-expansion. A shape memory polymer (SMP) stent may enhance flexibility, compliance, and drug elution compared to its current metallic counterparts. The purpose of this study was to describe the fabrication of a laser-activated SMP stent and demonstrate photothermal expansion of the stent in an in vitro artery model. Methods A novel SMP stent was fabricated from thermoplastic polyurethane. A solid SMP tube formed by dip coating a stainless steel pin was laser-etched to create the mesh pattern of the finished stent. The stent was crimped over a fiber-optic cylindrical light diffuser coupled to an infrared diode laser. Photothermal actuation of the stent was performed in a water-filled mock artery. Results At a physiological flow rate, the stent did not fully expand at the maximum laser power (8.6 W) due to convective cooling. However, under zero flow, simulating the technique of endovascular flow occlusion, complete laser actuation was achieved in the mock artery at a laser power of ~8 W. Conclusion We have shown the design and fabrication of an SMP stent and a means of light delivery for photothermal actuation. Though further studies are required to optimize the device and assess thermal tissue damage, photothermal actuation of the SMP stent was demonstrated. PMID:18042294

  3. A new large-scale process for taxol and related taxanes from Taxus brevifolia.

    PubMed

    Rao, K V; Hanuman, J B; Alvarez, C; Stoy, M; Juchum, J; Davies, R M; Baxley, R

    1995-07-01

    In view of the demonstrated antitumor activity of taxol, ready availability of the drug is important. The current isolation methods starting from the bark of Taxus brevifolia involve multiple manipulations, leading to only taxol and in a yield of 0.01%. A new process consisting of a single reverse phase column is introduced here, and the present purpose is to determine its large scale applicability. The chloroform extractable fraction of the bark of T. brevifolia is applied directly on to a C-18 bonded silica column in 25% acetonitrile/water, with elution using a step gradient: 30-50% acetonitrile/water. On standing, eight different taxanes, including taxol, crystallize out directly from different fractions. The crystals are filtered and purified further by recrystallization. Taxol and four other taxanes are purified this way. The other three require a short silica column. Taxol is freed from cephalomannine by selective ozonolysis. The large scale process gave taxol (0.04%), 10-deacetylbaccatin III (0.02%), 10-deacetyl taxol-7-xyloside (0.1%), 10-deacetyl taxol-C-7-xyloside (0.04%), 10-deacetyl cephalomannine-7-xyloside (0.006%), taxol-7-xyloside (0.008%), 10-deacetyl taxol (0.008%) and cephalomannine (0.004%). Processing of the needles of T. brevifolia gave brevifoliol (0.17%), and that of the wood, 10-deacetyl taxol-C-7-xyloside (0.01%) and 10-deacetyl taxol-C. The reverse phase column process is simpler (one column, direct crystallization), more efficient (eight taxanes obtained simultaneously) and also gives higher yields.

  4. Triclosan loaded ureteral stents decrease proteus mirabilis 296 infection in a rabbit urinary tract infection model.

    PubMed

    Cadieux, Peter A; Chew, Ben H; Knudsen, Bodo E; Dejong, Kathy; Rowe, Elaine; Reid, Gregor; Denstedt, John D

    2006-06-01

    Infection and encrustation remain major limitations of ureteral stent use and to our knowledge no device has completely overcome these obstacles to date. Triclosan is a biocide currently used in a plethora of consumer and medical products that has recently been loaded into a ureteral stent. Using a rabbit model of UTI we examined the effects of triclosan impregnated stent segments on the growth and survival of Proteus mirabilis, a uropathogen commonly associated with device related UTI and encrustation. A total of 48 male New Zealand White rabbits were instilled transurethrally with 1 x 10(6) P. mirabilis 296. A stent curl from a triclosan eluting, Percuflex Plus or Optima ureteral stent was placed intravesically. Urine was cultured on days 1, 3 and 7. On day 7 the stents were assessed for encrustation and viable organisms, while the bladders were scored for the degree of inflammation. Throughout the study urine isolated from the triclosan group contained significantly fewer viable organisms than controls with 7 of 13 animals completely clearing the infection by day 7. Similarly 9 of 13 triclosan eluting stents showed no viable organisms upon recovery and the remaining 4 showed significantly fewer organisms than controls. Urine and stents in all controls were positive for P. mirabilis at all time points. Although there was no significant difference in encrustation among the groups, bladders harvested from the triclosan group demonstrated significantly less inflammation. Triclosan eluting stents greatly decreased P. mirabilis growth and survival in a rabbit UTI model compared to controls. These stents may prove useful for decreasing device related P. mirabilis UTIs.

  5. Potential mechanisms of in-stent occlusion in the femoropopliteal artery: an angioscopic assessment.

    PubMed

    Ishihara, Takayuki; Iida, Osamu; Okamoto, Shin; Fujita, Masashi; Masuda, Masaharu; Nanto, Kiyonori; Shiraki, Tatsuya; Kanda, Takashi; Tsujimura, Takuya; Okuno, Shota; Yanaka, Koji; Uematsu, Masaaki

    2017-10-01

    Although stent implantation has become widespread for the treatment of patients with peripheral artery disease with femoropopliteal (FP) lesions, in-stent restenosis, especially in-stent occlusion (ISO), remains as a major concern for refractory recurrence. Furthermore, the mechanisms of ISO in FP lesions have not been well elucidated. We performed angioscopy for 6 lesions (bare-metal stent: 3, drug-eluting stent: 3) from 5 patients (mean age 74 ± 10 years, male 40 %) with ISO in the FP artery immediately after wire-passing or thrombus aspiration. The presence of thrombus as well as the presence and location of organic stenosis were evaluated. Median duration from stent implantation to angioscopic evaluation was 1099.5 (514.5-2272.5) days, while the duration from recurrence of symptoms to angioscopic evaluation was 45 (5.75-60) days. Mixed thrombi were observed in all stents. Organic stenosis was detected at the proximal edge of the stents in 5 lesions. Organic stenosis was observed at the overlapping segment of the stent in one lesion. The distal edge of the stents could be evaluated in 3 lesions, and all of them showed organic stenosis at the site. Mixed thrombi and organic stenosis were observed in all stents. Partial development of organic stenosis in a stent followed by thrombus formation may be the potential mechanism of the development of ISO in the FP artery though the sample size of this study was small and it had no serial angioscopic data so that we should consider it as preliminary one at best.

  6. Assessment of genetic and epigenetic variation during long-term Taxus cell culture.

    PubMed

    Fu, Chunhua; Li, Liqin; Wu, Wenjuan; Li, Maoteng; Yu, Xiaoqing; Yu, Longjiang

    2012-07-01

    Gradual loss of secondary metabolite production is a common obstacle in the development of a large-scale plant cell production system. In this study, cell morphology, paclitaxel (Taxol®) biosynthetic ability, and genetic and epigenetic variations in the long-term culture of Taxus media cv Hicksii cells were assessed over a 5-year period to evaluate the mechanisms of the loss of secondary metabolites biosynthesis capacity in Taxus cell. The results revealed that morphological variations, gradual loss of paclitaxel yield and decreased transcriptional level of paclitaxel biosynthesis key genes occurred during long-term subculture. Genetic and epigenetic variations in these cultures were also studied at different times during culture using amplified fragment-length polymorphism (AFLP), methylation-sensitive amplified polymorphism (MSAP), and high-performance liquid chromatography (HPLC) analyses. A total of 32 primer combinations were used in AFLP amplification, and none of the AFLP loci were found to be polymorphic, thus no major genetic rearrangements were detected in any of the tested samples. However, results from both MSAP and HPLC indicated that there was a higher level of DNA methylation in the low-paclitaxel yielding cell line after long-term culture. Based on these results, we proposed that accumulation of paclitaxel in Taxus cell cultures might be regulated by DNA methylation. To our knowledge, this is the first report of increased methylation with the prolongation of culture time in Taxus cell culture. It provides substantial clues for exploring the gradual loss of the taxol biosynthesis capacity of Taxus cell lines during long-term subculture. DNA methylation maybe involved in the regulation of paclitaxel biosynthesis in Taxus cell culture.

  7. Clinical presentation and outcomes of coronary in-stent restenosis across 3-stent generations.

    PubMed

    Magalhaes, Marco A; Minha, Sa'ar; Chen, Fang; Torguson, Rebecca; Omar, Al Fazir; Loh, Joshua P; Escarcega, Ricardo O; Lipinski, Michael J; Baker, Nevin C; Kitabata, Hironori; Ota, Hideaki; Suddath, William O; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron

    2014-12-01

    Clinical presentation of bare metal stent in-stent restenosis (ISR) in patients undergoing target lesion revascularization is well characterized and negatively affects on outcomes, whereas the presentation and outcomes of first- and second-generation drug-eluting stents (DESs) remains under-reported. The study included 909 patients (1077 ISR lesions) distributed as follows: bare metal stent (n=388), first-generation DES (n=425), and second-generation DES (n=96), categorized into acute coronary syndrome (ACS) or non-ACS presentation mode at the time of first target lesion revascularization. ACS was further classified as myocardial infarction (MI) and unstable angina. For bare metal stent, first-generation DES and second-generation DES, ACS was the clinical presentation in 67.8%, 71.0%, and 66.7% of patients, respectively (P=0.470), whereas MI occurred in 10.6%, 10.1%, and 5.2% of patients, respectively (P=0.273). The correlates for MI as ISR presentation were current smokers (odds ratio, 3.02; 95% confidence interval [CI], 1.78-5.13; P<0.001), and chronic renal failure (odds ratio, 2.73; 95% CI, 1.60-4.70; P<0.001), with a protective trend for the second-generation DES ISR (odds ratio, 0.35; 95% CI, 0.12-1.03; P=0.060). ACS presentations had an independent effect on major adverse cardiac events (death, MI, and re-target lesion revascularization) at 6 months (MI versus non-ACS: adjusted hazard ratio, 4.06; 95% CI, 1.84-8.94; P<0.001; unstable angina versus non-ACS: adjusted hazard ratio, 1.98; 95% CI, 1.01-3.87; P=0.046). ISR clinical presentation is similar irrespective of stent type. MI as ISR presentation seems to be associated with patient and not device-related factors. ACS as ISR presentation has an independent effect on major adverse cardiac events, suggesting that ISR remains a hazard and should be minimized. © 2014 American Heart Association, Inc.

  8. Extra-anatomic bypass for recurrent abdominal aortic and renal in-stent stenoses following radiotherapy for neuroblastoma.

    PubMed

    Luehr, Maximilian; Siepe, Matthias; Beyersdorf, Friedhelm; Schlensak, Christian

    2009-04-01

    We describe the case of an 11-year-old girl with an abdominal neuroblastoma which was operated and intraoperatively irradiated nine years ago. After six years, she developed stenoses of the infrarenal abdominal aorta and both renal arteries. Initial treatment of the stenosed vessels comprised endovascular balloon dilatations and repeated stent-graft implantations, including drug eluting stents. However, severe in-stent stenoses occurred during follow-up and the girl developed acute renal failure. Open surgery was performed with two extra-anatomic bypasses, a thoracic-to-abdominal aortic bypass and a left iliac-to-renal bypass, on an urgent basis. The postoperative course was uneventful and the patient was discharged home two weeks after the operation with full recovery of renal function. We conclude that endovascular stent-graft placement in children can only be a palliative treatment due to outgrowing of the stent-graft and the potential risk of re-stenosis, especially after a history of irradiation. Vascular surgery with placement of extra-anatomic bypasses will provide a definite treatment.

  9. The (PrS/HGF-pDNA) multilayer films for gene-eluting stent coating: Gene-protecting, anticoagulation, antibacterial properties, and in vivo antirestenosis evaluation.

    PubMed

    Chang, Hao; Ren, Ke-feng; Zhang, He; Wang, Jin-lei; Wang, Bai-liang; Ji, Jian

    2015-02-01

    Vascular gene-eluting stents (GES) is a promising strategy for treatment of cardiovascular disease. Very recently, we have proved that the (protamine sulfate/plasmid DNA encoding hepatocyte growth factor) (PrS/HGF-pDNA) multilayer can serve as a powerful tool for enhancing competitiveness of endothelial cell over smooth muscle cell, which opens perspectives for the regulation of intercellular competitiveness in the field of interventional therapy. However, before the gene multilayer films could be used in vascular stents for real clinical application, the preservation of gene bioactivity during the industrial sterilization and the hemocompatibility of film should be taken into account. Actually, both are long been ignored issues in the field of gene coating for GES. In this study, we demonstrate that the (PrS/HGF-pDNA) multilayer film exhibits the good gene-protecting abilities, which is confirmed by using the industrial sterilizations (gamma irradiation and ethylene oxide) and a routine storage condition (dry state at 4°C for 30 days). Furthermore, hemocompatible measurements (such as platelet adhesion and whole blood coagulation) and antibacterial assays (bacteria adhesion and growth inhibition) indicate the good anticoagulation and antibacterial properties of the (PrS/HGF-pDNA) multilayer film. The in vivo preliminary data of angiography and histological analysis suggest that the (PrS/HGF-pDNA) multilayer coated stent can reduce the in-stent restenosis. This work reveals that the (PrS/HGF-pDNA) multilayer film could be a promising candidate as coating for GES, which is of great potential in future clinic application. © 2014 Wiley Periodicals, Inc.

  10. Late adverse events after implantation of sirolimus-eluting stent and bare-metal stent: long-term (5-7 years) follow-up of the Coronary Revascularization Demonstrating Outcome study-Kyoto registry Cohort-2.

    PubMed

    Natsuaki, Masahiro; Morimoto, Takeshi; Furukawa, Yutaka; Nakagawa, Yoshihisa; Kadota, Kazushige; Yamaji, Kyohei; Ando, Kenji; Shizuta, Satoshi; Shiomi, Hiroki; Tada, Tomohisa; Tazaki, Junichi; Kato, Yoshihiro; Hayano, Mamoru; Abe, Mitsuru; Tamura, Takashi; Shirotani, Manabu; Miki, Shinji; Matsuda, Mitsuo; Takahashi, Mamoru; Ishii, Katsuhisa; Tanaka, Masaru; Aoyama, Takeshi; Doi, Osamu; Hattori, Ryuichi; Kato, Masayuki; Suwa, Satoru; Takizawa, Akinori; Takatsu, Yoshiki; Shinoda, Eiji; Eizawa, Hiroshi; Takeda, Teruki; Lee, Jong-Dae; Inoko, Moriaki; Ogawa, Hisao; Hamasaki, Shuichi; Horie, Minoru; Nohara, Ryuji; Kambara, Hirofumi; Fujiwara, Hisayoshi; Mitsudo, Kazuaki; Nobuyoshi, Masakiyo; Kita, Toru; Kimura, Takeshi

    2014-04-01

    Late adverse events such as very late stent thrombosis (VLST) or late target-lesion revascularization (TLR) after first-generation sirolimus-eluting stents (SES) implantation have not been yet fully characterized at long term in comparison with those after bare-metal stent (BMS) implantation. Among 13 058 consecutive patients undergoing first percutaneous coronary intervention in the Coronary REvascularization Demonstrating Outcome study-Kyoto registry Cohort-2, 5078 patients were treated with SES only, and 5392 patients were treated with BMS only. During 7-year follow-up, VLST and late TLR beyond 1 year after SES implantation occurred constantly and without attenuation at 0.24% per year and at 2.0% per year, respectively. Cumulative 7-year incidence of VLST was significantly higher in the SES group than that in the BMS group (1.43% versus 0.68%, P<0.0001). However, there was no excess of all-cause death beyond 1 year in the SES group as compared with that in the BMS group (20.8% versus 19.6%, P=0.91). Cumulative incidences of late TLR (both overall and clinically driven) were also significantly higher in the SES group than in the BMS group (12.0% versus 4.1%, P<0.0001 and 8.5% versus 2.6%, P<0.0001, respectively), leading to late catch-up of the SES group to the BMS group regarding TLR through the entire 7-year follow-up (18.8% versus 25.2%, and 10.6% versus 10.2%, respectively). Clinical presentation as acute coronary syndrome was more common at the time of late SES TLR compared with early SES TLR (21.2% and 10.0%). Late catch-up phenomenon regarding stent thrombosis and TLR was significantly more pronounced with SES than that with BMS. This limitation should remain the target for improvements of DES technology.

  11. Ureteral Stents and Foley Catheters-Associated Urinary Tract Infections: The Role of Coatings and Materials in Infection Prevention

    PubMed Central

    Lo, Joey; Lange, Dirk; Chew, Ben H.

    2014-01-01

    Urinary tract infections affect many patients, especially those who are admitted to hospital and receive a bladder catheter for drainage. Catheter associated urinary tract infections are some of the most common hospital infections and cost the health care system billions of dollars. Early removal is one of the mainstays of prevention as 100% of catheters become colonized. Patients with ureteral stents are also affected by infection and antibiotic therapy alone may not be the answer. We will review the current evidence on how to prevent infections of urinary biomaterials by using different coatings, new materials, and drug eluting technologies to decrease infection rates of ureteral stents and catheters. PMID:27025736

  12. Ureteral Stents and Foley Catheters-Associated Urinary Tract Infections: The Role of Coatings and Materials in Infection Prevention.

    PubMed

    Lo, Joey; Lange, Dirk; Chew, Ben H

    2014-03-10

    Urinary tract infections affect many patients, especially those who are admitted to hospital and receive a bladder catheter for drainage. Catheter associated urinary tract infections are some of the most common hospital infections and cost the health care system billions of dollars. Early removal is one of the mainstays of prevention as 100% of catheters become colonized. Patients with ureteral stents are also affected by infection and antibiotic therapy alone may not be the answer. We will review the current evidence on how to prevent infections of urinary biomaterials by using different coatings, new materials, and drug eluting technologies to decrease infection rates of ureteral stents and catheters.

  13. Absolute change in fasting plasma glucose over 12 months is associated with 2-year and 5-year major adverse cardiovascular events in patients with drug-eluting stent implants.

    PubMed

    Kang, Dong Oh; Seo, Hong Seog; Choi, Byung Geol; Lee, Eunmi; Kim, Ji Park; Lee, Sun Ki; Im, Sung Il; Na, Jin Oh; Choi, Cheol Ung; Lim, Hong Euy; Kim, Jin Won; Kim, Eung Ju; Rha, Seung-Woon; Park, Chang Gyu; Oh, Dong Joo

    2015-01-20

    Major adverse cardiovascular events (MACEs) in patients with or without cardiovascular disease (CVD) are greatly affected by various factors associated with metabolism and inflammation. To determine which clinical parameters at treatment are associated with the development of 2-year and 5-year MACEs in high-risk patients with CVD who have undergone drug-eluting stent (DES) implantation. The present study involved a total of 432 patients who underwent percutaneous coronary intervention with DES. Variables representing the average and absolute amount of change in clinical parameters over the 12-month follow-up were assessed for association with 2-year and 5-year development of MACE. The study population was divided into quartiles for the variable showing the highest correlation to MACE development. Estimated incidence of 2-year and 5-year MACEs for each of the quartiles was determined by survival curve analysis, and subgroup analysis was performed for patients with diabetes and statin users. Absolute change in fasting plasma glucose (FPG) over 12 months showed the highest correlation with 2-year and 5-year MACE development. The estimated incidence of MACE increased with increasing quartiles for absolute change in FPG. The association between absolute change in FPG and MACE development exhibited a stronger relationship for the specific subgroups of patients with diabetes and statin users. Increases and decreases in FPG had a comparable contribution to MACE development. A greater absolute change in FPG over 12 months post-PCI is an independent risk factor for 2-year and 5-year MACE development in DES-implanted patients, especially in the diabetes and statin users. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  14. Sensor to detect endothelialization on an active coronary stent

    PubMed Central

    2010-01-01

    Background A serious complication with drug-eluting coronary stents is late thrombosis, caused by exposed stent struts not covered by endothelial cells in the healing process. Real-time detection of this healing process could guide physicians for more individualized anti-platelet therapy. Here we present work towards developing a sensor to detect this healing process. Sensors on several stent struts could give information about the heterogeneity of healing across the stent. Methods A piezoelectric microcantilever was insulated with parylene and demonstrated as an endothelialization detector for incorporation within an active coronary stent. After initial characterization, endothelial cells were plated onto the cantilever surface. After they attached to the surface, they caused an increase in mass, and thus a decrease in the resonant frequencies of the cantilever. This shift was then detected electrically with an LCR meter. The self-sensing, self-actuating cantilever does not require an external, optical detection system, thus allowing for implanted applications. Results A cell density of 1300 cells/mm2 on the cantilever surface is detected. Conclusions We have developed a self-actuating, self-sensing device for detecting the presence of endothelial cells on a surface. The device is biocompatible and functions reliably in ionic liquids, making it appropriate for implantable applications. This sensor can be placed along the struts of a coronary stent to detect when the struts have been covered with a layer of endothelial cells and are no longer available surfaces for clot formation. Anti-platelet therapy can be adjusted in real-time with respect to a patient's level of healing and hemorrhaging risks. PMID:21050471

  15. Cost-effectiveness of percutaneous coronary intervention with drug-eluting stents in patients with multivessel coronary artery disease compared to coronary artery bypass surgery five-years after intervention

    PubMed Central

    Krenn, Lisa; Kopp, Christoph; Glogar, Dietmar; Lang, Irene M; Delle-Karth, Georg; Neunteufl, Thomas; Kreiner, Gerhard; Kaider, Alexandra; Bergler-Klein, Jutta; Khorsand, Aliasghar; Nikfardjam, Mariam; Laufer, Günther; Maurer, Gerald; Gyöngyösi, Mariann

    2014-01-01

    Objectives Cost-effectiveness of percutaneous coronary intervention (PCI) using drug-eluting stents (DES), and coronary artery bypass surgery (CABG) was analyzed in patients with multivessel coronary artery disease over a 5-year follow-up. Background DES implantation reducing revascularization rate and associated costs might be attractive for health economics as compared to CABG. Methods Consecutive patients with multivessel DES-PCI (n = 114, 3.3 ± 1.2 DES/patient) or CABG (n = 85, 2.7 ± 0.9 grafts/patient) were included prospectively. Primary endpoint was cost-benefit of multivessel DES-PCI over CABG, and the incremental cost-effectiveness ratio (ICER) was calculated. Secondary endpoint was the incidence of major adverse cardiac and cerebrovascular events (MACCE), including acute myocardial infarction (AMI), all-cause death, revascularization, and stroke. Results Despite multiple uses for DES, in-hospital costs were significantly less for PCI than CABG, with 4551 €/patient difference between the groups. At 5-years, the overall costs remained higher for CABG patients (mean difference 5400 € between groups). Cost-effectiveness planes including all patients or subgroups of elderly patients, diabetic patients, or Syntax score >32 indicated that CABG is a more effective, more costly treatment mode for multivessel disease. At the 5-year follow-up, a higher incidence of MACCE (37.7% vs. 25.8%; log rank P = 0.048) and a trend towards more AMI/death/stroke (25.4% vs. 21.2%, log rank P = 0.359) was observed in PCI as compared to CABG. ICER indicated 45615 € or 126683 € to prevent one MACCE or AMI/death/stroke if CABG is performed. Conclusions Cost-effectiveness analysis of DES-PCI vs. CABG demonstrated that CABG is the most effective, but most costly, treatment for preventing MACCE in patients with multivessel disease. © 2014 Wiley Periodicals, Inc. PMID:24403120

  16. One-year clinical outcome of biodegradable polymer sirolimus-eluting stent in all-comers population. Insight from the ULISSE registry (ULtimaster Italian multicenter all comerS Stent rEgistry).

    PubMed

    Godino, Cosmo; Beneduce, Alessandro; Ferrante, Giuseppe; Ielasi, Alfonso; Pivato, Andrea Carlo; Chiarito, Mauro; Cappelletti, Alberto; Perfetti, Giulia; Magni, Valeria; Prati, Eugenio; Falcone, Stefania; Pierri, Adele; De Martini, Stefano; Montorfano, Matteo; Parisi, Rosario; Rutigliano, David; Locuratolo, Nicola; Anzuini, Angelo; Tespilli, Maurizio; Margonato, Alberto; Benassi, Alberto; Briguori, Carlo; Fabbiocchi, Franco; Reimers, Bernhard; Bartorelli, Antonio; Colombo, Antonio

    2018-06-01

    This study was designed to confirm in a large population of unselected patients the promising results of Ultimaster® biodegradable polymer sirolimus-eluting stent (BP-SES) already shown in previous trial. ULISSE is an observational, multicenter, national registry evaluating all patients undergoing PCI with the Ultimaster® BP-SES. Incidence of 1-year TLF (cardiac death or target vessel MI or clinically indicated TLR) was the primary endpoint. Pre-specified subgroup analysis was performed for diabetic patients and for those with lesion longer than 25 mm, bifurcation and CTO lesions. 1660 patients were enrolled in 9 Italian cardiology centers, 82% were males, mean age of 68 ± 10 years, and 29% were diabetics. Overall 2422 lesions were treated, 65% type B2/C lesions, 7% CTOs, 17% bifurcations and 38% long lesions. The incidence of 1-year TLF was 5%, with 3.2% of clinically indicated TLR. TLF occurred in 8% of the patients with diabetes mellitus, and 7% in bifurcation, 6.7% in CTO and 6.2% in long lesions. Definite overall ST was 0.9%, and 1.2% in patients treated for type B2/C lesions. Multivariate logistic regression analysis identified stenting on unprotected LMT (OR = 4.80), stenting on ISR lesion (OR = 3.19) and need for rotational atherectomy (OR = 6.24) as the strongest independent predictors of TLF. The results of this national all-comers registry show that the Ultimaster® BP-SES real-world performance was comparable with that observed in the clinical trial, with low rate of primary endpoint and TLR. Long term follow-up will be necessary to prove the theoretical advantage of the BP-SES over time. Copyright © 2017. Published by Elsevier B.V.

  17. Local sustained delivery of acetylsalicylic acid via hybrid stent with biodegradable nanofibers reduces adhesion of blood cells and promotes reendothelialization of the denuded artery

    PubMed Central

    Lee, Cheng-Hung; Lin, Yu-Huang; Chang, Shang-Hung; Tai, Chun-Der; Liu, Shih-Jung; Chu, Yen; Wang, Chao-Jan; Hsu, Ming-Yi; Chang, Hung; Chang, Gwo-Jyh; Hung, Kuo-Chun; Hsieh, Ming-Jer; Lin, Fen-Chiung; Hsieh, I-Chang; Wen, Ming-Shien; Huang, Yenlin

    2014-01-01

    Incomplete endothelialization, blood cell adhesion to vascular stents, and inflammation of arteries can result in acute stent thromboses. The systemic administration of acetylsalicylic acid decreases endothelial dysfunction, potentially reducing thrombus, enhancing vasodilatation, and inhibiting the progression of atherosclerosis; but, this is weakened by upper gastrointestinal bleeding. This study proposes a hybrid stent with biodegradable nanofibers, for the local, sustained delivery of acetylsalicylic acid to injured artery walls. Biodegradable nanofibers are prepared by first dissolving poly(D,L)-lactide-co-glycolide and acetylsalicylic acid in 1,1,1,3,3,3-hexafluoro-2-propanol. The solution is then electrospun into nanofibrous tubes, which are then mounted onto commercially available bare-metal stents. In vitro release rates of pharmaceuticals from nanofibers are characterized using an elution method, and a highperformance liquid chromatography assay. The experimental results suggest that biodegradable nanofibers release high concentrations of acetylsalicylic acid for three weeks. The in vivo efficacy of local delivery of acetylsalicylic acid in reducing platelet and monocyte adhesion, and the minimum tissue inflammatory reaction caused by the hybrid stents in treating denuded rabbit arteries, are documented. The proposed hybrid stent, with biodegradable acetylsalicylic acid-loaded nanofibers, substantially contributed to local, sustained delivery of drugs to promote re-endothelialization and reduce thrombogenicity in the injured artery. The stents may have potential applications in the local delivery of cardiovascular drugs. Furthermore, the use of hybrid stents with acetylsalicylic acid-loaded nanofibers that have high drug loadings may provide insight into the treatment of patients with high risk of acute stent thromboses. PMID:24421640

  18. Acute stent recoil and optimal balloon inflation strategy: an experimental study using real-time optical coherence tomography.

    PubMed

    Kitahara, Hideki; Waseda, Katsuhisa; Yamada, Ryotaro; Otagiri, Kyuhachi; Tanaka, Shigemitsu; Kobayashi, Yuhei; Okada, Kozo; Kume, Teruyoshi; Nakagawa, Kaori; Teramoto, Tomohiko; Ikeno, Fumiaki; Yock, Paul G; Fitzgerald, Peter J; Honda, Yasuhiro

    2016-06-12

    Our aim was to evaluate stent expansion and acute recoil at deployment and post-dilatation, and the impact of post-dilatation strategies on final stent dimensions. Optical coherence tomography (OCT) was performed on eight bare metal platforms of drug-eluting stents (3.0 mm diameter, n=6 for each) during and after balloon inflation in a silicone mock vessel. After nominal-pressure deployment, a single long (30 sec) vs. multiple short (10 sec x3) post-dilatations were performed using a non-compliant balloon (3.25 mm, 20 atm). Stent areas during deployment with original delivery systems were smaller in stainless steel stents than in cobalt-chromium and platinum-chromium stents (p<0.001), whereas subsequent acute recoil was comparable among the three materials. At post-dilatation, acute recoil was greater in cobalt-chromium and platinum-chromium stents than in stainless steel stents (p<0.001), resulting in smaller final stent areas in cobalt-chromium and platinum-chromium stents than in stainless steel stents (p<0.001). In comparison between conventional and latest-generation cobalt-chromium stents, stent areas were not significantly different after both deployment and post-dilatation. With multiple short post-dilatations, acute recoil was significantly improved from first to third short inflation (p<0.001), achieving larger final area than a single long inflation, despite stent materials/designs (p<0.001). Real-time OCT revealed significant acute recoil in all stent types. Both stent materials/designs and post-dilatation strategies showed a significant impact on final stent expansion.

  19. Diabetes mellitus: a prothrombotic state Implications for outcomes after coronary revascularization

    PubMed Central

    Cola, Clarissa; Brugaletta, Salvatore; Yuste, Victoria Martín; Campos, Bieito; Angiolillo, Dominick J; Sabaté, Manel

    2009-01-01

    Coronary stent thrombosis is a serious problem in the drug-eluting stent era. Despite aggressive antiplatelet therapy during and after percutaneous coronary intervention (PCI), the incidence of sub-acute stent thrombosis remains approximately 0.5%–2%, which may represent a catastrophic clinical situation. Both procedural factors and discontinuation of antiplatelet therapy are normally associated with this event. We report on simultaneous stent thromboses of two drug-eluting stents implanted in two different vessels, which resulted in a life-threatening clinical condition. Possible contributing factors that led to synergistic thrombotic effects are discussed. PMID:19436654

  20. Diversity of endophytic fungi and screening of fungal paclitaxel producer from Anglojap yew, Taxus x media

    PubMed Central

    2013-01-01

    Background Endophytic fungi represent underexplored resource of novel lead compounds and have a capacity to produce diverse class of plant secondary metabolites. Here we investigated endophytic fungi diversity and screening of paclitaxel-producing fungi from Taxus x media. Results Eighty-one endophytic fungi isolated from T. media were grouped into 8 genera based on the morphological and molecular identification. Guignardia and Colletotrichum were the dominant genera, whereas the remaining genera were infrequent groups. The genera Glomerella and Gibberella were first reported in Taxus. Three representative species of the distinct genera gave positive hits by molecular marker screening and were capable of producing taxol which were validated by HPLC-MS. Among these 3 taxol-producing fungi, the highest yield of taxol was 720 ng/l by Guignardia mangiferae HAA11 compared with those of Fusarium proliferatum HBA29 (240 ng/l) and Colletotrichum gloeosporioides TA67 (120 ng/l). This is the first report of taxol producer from Guignardia. Moreover, the lower similarities of ts and bapt between microbial and plant origin suggested that fungal taxol biosynthetic cluster might be repeatedly invented during evolution, nor horizontal gene transfer from Taxus species. Conclusions Taxol-producing endophytic fungi could be a fascinating reservoir to generate taxol-related drug lead and to elucidate the remained 5 unknown genes or the potential regulation mechanism in the taxol biosynthesis pathway. PMID:23537181

  1. Bioresorbable scaffolds for percutaneous coronary interventions

    PubMed Central

    Gogas, Bill D.

    2014-01-01

    Innovations in drug-eluting stents (DES) have substantially reduced rates of in-segment restenosis and early stent thrombosis, improving clinical outcomes following percutaneous coronary interventions (PCI). However a fixed metallic implant in a vessel wall with restored patency and residual disease remains a precipitating factor for sustained local inflammation, in-stent neo-atherosclerosis and impaired vasomotor function increasing the risk for late complications attributed to late or very late stent thrombosis and late target lesion revascularization (TLR) (late catch-up). The quest for optimal coronary stenting continues by further innovations in stent design and by using biocompatible materials other than cobalt chromium, platinum chromium or stainless steel for engineering coronary implants. Bioresorbable scaffolds made of biodegradable polymers or biocorrodible metals with properties of transient vessel scaffolding, local drug-elution and future restoration of vessel anatomy, physiology and local hemodynamics have been recently developed. These devices have been utilized in selected clinical applications so far providing preliminary evidence of safety showing comparable performance with current generation drug-eluting stents (DES). Herein we provide a comprehensive overview of the current status of these technologies, we elaborate on the potential benefits of transient coronary scaffolds over permanent stents in the context of vascular reparation therapy, and we further focus on the evolving challenges these devices have to overcome to compete with current generation DES. Condensed Abstract:: The quest for optimizing percutaneous coronary interventions continues by iterative innovations in device materials beyond cobalt chromium, platinum chromium or stainless steel for engineering coronary implants. Bioresorbable scaffolds made of biodegradable polymers or biocorrodible metals with properties of transient vessel scaffolding; local drug-elution and future

  2. Small-Interfering RNA–Eluting Surfaces as a Novel Concept for Intravascular Local Gene Silencing

    PubMed Central

    Nolte, Andrea; Walker, Tobias; Schneider, Martina; Kray, Oya; Avci-Adali, Meltem; Ziemer, Gerhard; Wendel, Hans Peter

    2011-01-01

    New drug-eluting stent (DES) methods have recently been demonstrated to improve outcomes of intravascular interventions. A novel technique is the design of gene-silencing stents that elute specific small-interfering RNAs (siRNAs) for better vascular wall regeneration. Although siRNAs used to alter gene expression have surpassed expectations in in vitro experiments, the functional and local delivery of siRNAs is still the major obstacle for the in vivo application of RNA interference. In this preliminary in vitro study we investigated a surface-immobilized siRNA delivery technique that would be readily adaptable for local intravascular applications in vivo. The transfection potency of gelatin coatings consisting of a specific siRNA complexed with polyethylenimine (PEI) was examined in primary human endothelial cells by flow cytometry and quantitative real-time polymerase chain reaction. Several media conditions, such as the presence or absence of serum during cultivation, were investigated. Furthermore, different siRNA and PEI amounts, as well as nitrogen/phosphate ratios, were tested for their transfection efficiency. Gelatin coatings consisting of PEI and siRNA against an exemplary endothelial adhesion molecule receptor achieved a significant knockdown of around 70%. The transfection efficiency of the coatings was not influenced by the presence of serum. The results of this preliminary study support the expectation that this novel coating may be favorable for local in vivo gene silencing (for example, when immobilized on stents or balloons for percutanous transluminal coronary angioplasty). However, further animal experiments are needed to confirm the translation into clinical practice. This intriguing technology leads the way to more sophisticated and individualized coatings for the post-DES era, toward silencing of genes involved in the pathway of intimal hyperplasia. PMID:21792480

  3. Five-year outcomes in patients with left main disease treated with either percutaneous coronary intervention or coronary artery bypass grafting in the synergy between percutaneous coronary intervention with taxus and cardiac surgery trial.

    PubMed

    Morice, Marie-Claude; Serruys, Patrick W; Kappetein, A Pieter; Feldman, Ted E; Ståhle, Elisabeth; Colombo, Antonio; Mack, Michael J; Holmes, David R; Choi, James W; Ruzyllo, Witold; Religa, Grzegorz; Huang, Jian; Roy, Kristine; Dawkins, Keith D; Mohr, Friedrich

    2014-06-10

    Current guidelines recommend coronary artery bypass graft surgery (CABG) when treating significant de novo left main coronary artery (LM) stenosis; however, percutaneous coronary intervention (PCI) has a class IIa indication for unprotected LM disease in selected patients. This analysis compares 5-year clinical outcomes in PCI- and CABG-treated LM patients in the Synergy Between PCI With Taxus and Cardiac Surgery (SYNTAX) trial, the largest trial in this group to date. The SYNTAX trial randomly assigned 1800 patients with LM or 3-vessel disease to receive either PCI (with TAXUS Express paclitaxel-eluting stents) or CABG. The unprotected LM cohort (N=705) was predefined and powered. Major adverse cardiac and cerebrovascular event rates at 5 years was 36.9% in PCI patients and 31.0% in CABG patients (hazard ratio, 1.23 [95% confidence interval, 0.95-1.59]; P=0.12). Mortality rate was 12.8% and 14.6% in PCI and CABG patients, respectively (hazard ratio, 0.88 [95% confidence interval, 0.58-1.32]; P=0.53). Stroke was significantly increased in the CABG group (PCI 1.5% versus CABG 4.3%; hazard ratio, 0.33 [95% confidence interval, 0.12-0.92]; P=0.03) and repeat revascularization in the PCI arm (26.7% versus 15.5%; hazard ratio, 1.82 [95% confidence interval, 1.28-2.57]; P<0.01). Major adverse cardiac and cerebrovascular events were similar between arms in patients with low/intermediate SYNTAX scores but significantly increased in PCI patients with high scores (≥33). At 5 years, no difference in overall major adverse cardiac and cerebrovascular events was found between treatment groups. PCI-treated patients had a lower stroke but a higher revascularization rate versus CABG. These results suggest that both treatments are valid options for LM patients. The extent of disease should accounted for when choosing between surgery and PCI, because patients with high SYNTAX scores seem to benefit more from surgery compared with those in the lower tertiles. http

  4. Development of a functionalized polymer for stent coating in the arterial delivery of small interfering RNA.

    PubMed

    San Juan, Aurélie; Bala, Madiha; Hlawaty, Hanna; Portes, Patrick; Vranckx, Roger; Feldman, Laurent J; Letourneur, Didier

    2009-11-09

    In patients receiving drug eluting stents, there is a growing concern about both the long-term toxicity/degradability of the polymers used for the coating, and the nature of the therapeutic agents. We hypothesized that the use of a functionalized biocompatible polymer for a stent coating could be appropriate for local arterial therapy. A cationized pullulan hydrogel was thus prepared to cover bare metal stents that could be further loaded with small interfering RNA (siRNA) targeted at MMP2 for gene silencing in vascular cells. The efficient coverage of the stent struts by a smooth polymeric layer, which can withstand the crimping of the stent on a balloon-catheter and its deployment, was demonstrated by fluorescence microscopy, scanning electron microscopy, and atomic force microscopy. The release of siRNA from the stents was modulated by the presence of the cationic groups, as compared to noncationized pullulan hydrogel. In vivo implantation of coated stents was successful and cationized pullulan-based hydrogels loaded with siRNA in rabbit balloon-injured carotid arteries induced an uptake of siRNA into the arterial wall and a decrease of pro-MMP2 activity. These results suggest that cationized pullulan-based hydrogel could be used as a new biocompatible and biodegradable stent coating for local gene therapy in the arterial wall.

  5. In vivo performance of a drug-eluting contact lens to treat glaucoma for a month

    PubMed Central

    Ciolino, Joseph B.; Stefanescu, Cristina F.; Ross, Amy E.; Salvador-Culla, Borja; Cortez, Priscila; Ford, Eden M.; Wymbs, Kate A.; Sprague, Sarah L.; Mascoop, Daniel R.; Rudina, Shireen S.; Trauger, Sunia A.; Cade, Fabiano; Kohane, Daniel S.

    2013-01-01

    For nearly half a century, contact lenses have been proposed as a means of ocular drug delivery, but achieving controlled drug release has been a significant challenge. We have developed a drug-eluting contact lens designed for prolonged delivery of latanoprost for the treatment of glaucoma, the leading cause of irreversible blindness worldwide. Latanoprost-eluting contact lenses were created by encapsulating latanoprost–poly(lactic-co-glycolic acid) films in methafilcon by ultraviolet light polymerization. In vitro and in vivo studies showed an early burst of drug release followed by sustained release for one month. Contact lenses containing thicker drug–polymer films demonstrated released a greater amount of drug after the initial burst. In vivo, single contact lenses were able to achieve, for at least one month, latanoprost concentrations in the aqueous humor that were comparable to those achieved with topical latanoprost solution, the current first-line treatment for glaucoma. The lenses appeared safe in cell culture and animal studies. This contact lens design can potentially be used as a treatment for glaucoma and as a platform for other ocular drug delivery applications. PMID:24094935

  6. Drug-coated balloons for de novo lesions in small coronary arteries: rationale and design of BASKET-SMALL 2.

    PubMed

    Gilgen, Nicole; Farah, Ahmed; Scheller, Bruno; Ohlow, Marc-Alexander; Mangner, Norman; Weilenmann, Daniel; Wöhrle, Jochen; Jamshidi, Peiman; Leibundgut, Gregor; Möbius-Winkler, Sven; Zweiker, Robert; Krackhardt, Florian; Butter, Christian; Bruch, Leonhard; Kaiser, Christoph; Hoffmann, Andreas; Rickenbacher, Peter; Mueller, Christian; Stephan, Frank-Peter; Coslovsky, Michael; Jeger, Raban

    2018-05-01

    The treatment of coronary small vessel disease (SVD) remains an unresolved issue. Drug-eluting stents (DES) have limited efficacy due to increased rates of instent-restenosis, mainly caused by late lumen loss. Drug-coated balloons (DCB) are a promising technique because native vessels remain structurally unchanged. Basel Stent Kosten-Effektivitäts Trial: Drug-Coated Balloons vs. Drug-Eluting Stents in Small Vessel Interventions (BASKET-SMALL 2) is a multicenter, randomized, controlled, noninferiority trial of DCB vs DES in native SVD for clinical endpoints. Seven hundred fifty-eight patients with de novo lesions in vessels <3 mm in diameter and an indication for percutaneous coronary intervention such as stable angina pectoris, silent ischemia, or acute coronary syndromes are randomized 1:1 to angioplasty with DCB vs implantation of a DES after successful initial balloon angioplasty. The primary endpoint is the combination of cardiac death, nonfatal myocardial infarction, and target-vessel revascularization up to 1 year. Secondary endpoints include stent thrombosis, Bleeding Academic Research Consortium (BARC) type 3 to 5 bleeding, and long-term outcome up to 3 years. Based on clinical endpoints after 1 year, we plan to assess the noninferiority of DCB compared to DES in patients undergoing primary percutaneous coronary intervention for SVD. Results will be available in the second half of 2018. This study will compare DCB and DES regarding long-term safety and efficacy for the treatment of SVD in a large all-comer population. © 2018 The Authors. Clinical Cardiology published by Wiley Periodicals, Inc.

  7. Comparison of coronary bypass surgery with drug-eluting stenting for the treatment of left main and/or three-vessel disease: 3-year follow-up of the SYNTAX trial.

    PubMed

    Kappetein, Arie Pieter; Feldman, Ted E; Mack, Michael J; Morice, Marie-Claude; Holmes, David R; Ståhle, Elisabeth; Dawkins, Keith D; Mohr, Friedrich W; Serruys, Patrick W; Colombo, Antonio

    2011-09-01

    Long-term randomized comparisons of percutaneous coronary intervention (PCI) to coronary artery bypass grafting (CABG) in left main coronary (LM) disease and/or three-vessel disease (3VD) patients have been limited. This analysis compares 3-year outcomes in LM and/or 3VD patients treated with CABG or PCI with TAXUS Express stents. SYNTAX is an 85-centre randomized clinical trial (n= 1800). Prospectively screened, consecutive LM and/or 3VD patients were randomized if amenable to equivalent revascularization using either technique; if not, they were entered into a registry. Patients in the randomized cohort will continue to be followed for 5 years. At 3 years, major adverse cardiac and cerebrovascular events [MACCE: death, stroke, myocardial infarction (MI), and repeat revascularization; CABG 20.2% vs. PCI 28.0%, P< 0.001], repeat revascularization (10.7 vs. 19.7%, P< 0.001), and MI (3.6 vs. 7.1%, P= 0.002) were elevated in the PCI arm. Rates of the composite safety endpoint (death/stroke/MI 12.0 vs. 14.1%, P= 0.21) and stroke alone (3.4 vs. 2.0%, P= 0.07) were not significantly different between treatment groups. Major adverse cardiac and cerebrovascular event rates were not significantly different between arms in the LM subgroup (22.3 vs. 26.8%, P= 0.20) but were higher with PCI in the 3VD subgroup (18.8 vs. 28.8%, P< 0.001). At 3 years, MACCE was significantly higher in PCI- compared with CABG-treated patients. In patients with less complex disease (low SYNTAX scores for 3VD or low/intermediate terciles for LM patients), PCI is an acceptable revascularization, although longer follow-up is needed to evaluate these two revascularization strategies.

  8. Mechanical behavior of polymer-based vs. metallic-based bioresorbable stents

    PubMed Central

    Ang, Hui Ying; Huang, Ying Ying; Lim, Soo Teik; Wong, Philip; Joner, Michael

    2017-01-01

    Bioresorbable scaffolds (BRS) were developed to overcome the drawbacks of current metallic drug-eluting stents (DES), such as late in-stent restenosis and caging of the vessel permanently. The concept of the BRS is to provide transient support to the vessel during healing before being degraded and resorbed by the body, freeing the vessel and restoring vasomotion. The mechanical properties of the BRS are influenced by the choice of the material and processing methods. Due to insufficient radial strength of the bioresorbable material, BRS often required large strut profile as compared to conventional metallic DES. Having thick struts will in turn affect the deliverability of the device and may cause flow disturbance, thereby increasing the incidence of acute thrombotic events. Currently, the bioresorbable poly-l-lactic acid (PLLA) polymer and magnesium (Mg) alloys are being investigated as materials in BRS technologies. The bioresorption process, mechanical properties, in vitro observations and clinical outcomes of PLLA-based and Mg-based BRS will be examined in this review. PMID:28894598

  9. Paclitaxel-loaded poly(lactide-co-glycolide)/poly(ethylene vinyl acetate) composite for stent coating by ultrasonic atomizing spray.

    PubMed

    Yuk, Soon Hong; Oh, Keun Sang; Park, Jinah; Kim, Soon-Joong; Kim, Jung Ho; Kwon, Il Keun

    2012-04-01

    The mixture of poly(lactide-co-glycolide) (PLGA) and poly(ethylene vinyl acetate) (PEVA) forms a homogeneous liquid in an organic solvent such as tetrahydrofuran, and a phase-separated PLGA/PEVA composite can be prepared from it by evaporating the organic solvent. Exploiting this phenomenon, we designed a novel method of preparing a drug-loaded PLGA/PEVA composite and used it for coating drug-eluting stents (DESs). Paclitaxel (PTX), an anticancer drug, was chosen as a model drug. PLGA acts as a microdepot for PTX, and PEVA provides mechanical strength to the coating material. The presence of PLGA in the PLGA/PEVA composite suppressed PTX crystallization in the coating material, and PTX showed a sustained release rate over more than 30 days. The mechanical strength of the PLGA/PEVA composite was better than that of PEVA used as a control. After coating the stent with a PLGA/PEVA composite using ultrasonic atomizing spray, the morphology of the coated material was observed by scanning electron microscopy, and the release pattern of PTX was measured by high-performance liquid chromatography.

  10. Paclitaxel-loaded poly(lactide-co-glycolide)/poly(ethylene vinyl acetate) composite for stent coating by ultrasonic atomizing spray

    PubMed Central

    Yuk, Soon Hong; Oh, Keun Sang; Park, Jinah; Kim, Soon-Joong; Kim, Jung Ho; Kwon, Il Keun

    2012-01-01

    The mixture of poly(lactide-co-glycolide) (PLGA) and poly(ethylene vinyl acetate) (PEVA) forms a homogeneous liquid in an organic solvent such as tetrahydrofuran, and a phase-separated PLGA/PEVA composite can be prepared from it by evaporating the organic solvent. Exploiting this phenomenon, we designed a novel method of preparing a drug-loaded PLGA/PEVA composite and used it for coating drug-eluting stents (DESs). Paclitaxel (PTX), an anticancer drug, was chosen as a model drug. PLGA acts as a microdepot for PTX, and PEVA provides mechanical strength to the coating material. The presence of PLGA in the PLGA/PEVA composite suppressed PTX crystallization in the coating material, and PTX showed a sustained release rate over more than 30 days. The mechanical strength of the PLGA/PEVA composite was better than that of PEVA used as a control. After coating the stent with a PLGA/PEVA composite using ultrasonic atomizing spray, the morphology of the coated material was observed by scanning electron microscopy, and the release pattern of PTX was measured by high-performance liquid chromatography. PMID:27877483

  11. Paclitaxel-loaded poly(lactide-co-glycolide)/poly(ethylene vinyl acetate) composite for stent coating by ultrasonic atomizing spray

    NASA Astrophysics Data System (ADS)

    Yuk, Soon Hong; Oh, Keun Sang; Park, Jinah; Kim, Soon-Joong; Kim, Jung Ho; Kwon, Il Keun

    2012-04-01

    The mixture of poly(lactide-co-glycolide) (PLGA) and poly(ethylene vinyl acetate) (PEVA) forms a homogeneous liquid in an organic solvent such as tetrahydrofuran, and a phase-separated PLGA/PEVA composite can be prepared from it by evaporating the organic solvent. Exploiting this phenomenon, we designed a novel method of preparing a drug-loaded PLGA/PEVA composite and used it for coating drug-eluting stents (DESs). Paclitaxel (PTX), an anticancer drug, was chosen as a model drug. PLGA acts as a microdepot for PTX, and PEVA provides mechanical strength to the coating material. The presence of PLGA in the PLGA/PEVA composite suppressed PTX crystallization in the coating material, and PTX showed a sustained release rate over more than 30 days. The mechanical strength of the PLGA/PEVA composite was better than that of PEVA used as a control. After coating the stent with a PLGA/PEVA composite using ultrasonic atomizing spray, the morphology of the coated material was observed by scanning electron microscopy, and the release pattern of PTX was measured by high-performance liquid chromatography.

  12. Percuflex Helical Ureteral Stents Significantly Reduce Patient Analgesic Requirements Compared to Control Stents.

    PubMed

    Chew, Ben H; Rebullar, Karla A; Harriman, David; McDougall, Elspeth; Paterson, Ryan F; Lange, Dirk

    2017-12-01

    Ureteral stent symptoms are experienced by the majority of patients with ureteral stents. No one stent or technology has shown a clear advantage. The Helical™ stent, a spirally cut stent made of proprietary Percuflex™ material, was designed to conform to the shape of the ureter and better accommodate patient movement. We prospectively sought to compare unscheduled visits, analgesic use, and pain scores in patients who received a Percuflex Helical ureteral stent following ureteroscopy compared to a historical control group. Fifteen (n = 15) patients undergoing ureteroscopy for the treatment of kidney stones were consented for study. A Percuflex Helical ureteral stent was inserted after treating the urinary stone. The historical control group consisted of 30 patients, from a previous (ketorolac eluting) ureteral stent study utilizing the same protocol and clinical monitoring forms, who received a regular Percuflex ureteral stent. The control patients were matched by age and sex. The primary study outcome was to compare unscheduled visits. Secondary outcomes included comparison of Visual Pain Analog Scale (VPAS) scores and analgesic use between the two groups. There were no differences in the gender, age, BMI, or stone characteristics between groups. Both groups underwent retrograde ureteroscopy using holmium:YAG laser lithotripsy and stone fragmentation. There was a significant reduction in the amount of analgesics required in the Helical stent group (4.4 ± 7.99 mg morphine equivalents) compared to controls (16.75 ± 18.31 mg, p = 0.0035) to achieve similar VPAS scores. There was no difference in unscheduled visits (20%) or VPAS scores (13.84 ± 13.68 helical vs 14.29 ± 11.58 control, p = 0.7910) between groups. Patients who received a Percuflex Helical ureteral stent required significantly fewer analgesics than those who received a Percuflex stent and both had equivalent pain scores.

  13. Impact of Chronic Renal Failure on Safety and Effectiveness of Paclitaxel-Eluting Stents for Femoropopliteal Artery Disease: Subgroup Analysis from Zilver PTX Post-Market Surveillance Study in Japan.

    PubMed

    Ogawa, Yukihisa; Yokoi, Hiroyoshi; Ohki, Takao; Kichikawa, Kimihiko; Nakamura, Masato; Komori, Kimihiro; Nanto, Shinsuke; O'Leary, Erin E; Lottes, Aaron E; Saunders, Alan T; Dake, Michael D

    2017-11-01

    Favorable long-term outcomes of the Zilver PTX drug-eluting stent (DES) in femoropopliteal lesions have been demonstrated. Chronic renal failure (CRF) has been shown to be a risk factor for restenosis and decreased limb salvage. The results of the DES in patients with CRF have not previously been reported. This study compares the results with the DES in patients with CRF and those without CRF. This retrospective analysis from the Zilver PTX Japan Post-Market Surveillance Study included 321 patients with CRF and 584 patients without CRF. Outcomes included freedom from target lesion revascularization (TLR) and patency. Of the patients included in this subgroup analysis, 2-year data were available for 209 patients in the CRF group and 453 patients in the non-CRF group. The two groups were similar in terms of lesion length and the frequency of in-stent restenosis. Critical limb ischemia, severe calcification, and diabetes were more common in patients with CRF, whereas total occlusion was more common in patients without CRF. Freedom from TLR rates were 81.4 versus 84.9% (p = 0.24), and patency rates were 70.7 versus 70.3% (p = 0.95) in patients with and without CRF at 2 years, respectively. This is the first comparative study of the DES in femoropopliteal artery lesions in patients with and without CRF. These results indicate that the DES placed in femoropopliteal artery lesions of CRF patients is safe and effective with similar patency and TLR rates to patients without CRF. Level 3, Post-Market Surveillance Study.

  14. Chemical components of heartwood and sapwood of common Yew (Taxus baccata L.).

    PubMed

    Mertoğlu-Elmas, Gülnur

    2003-10-01

    Cell-wall components and solubility characteristics of the heartwood and sapwood of Taxus baccata L. were determined by methods of wood analysis and the differences between heartwood and sapwood were established. When we observe the data obtained, it is seen that the amount of extractive material found in the heartwood is substantially higher than the sapwood. The extractive material in Taxus baccata L. is originated from the hidden epithelial cells surrounded by resin canals.

  15. Intravascular imaging comparison of two metallic limus-eluting stents abluminally coated with biodegradable polymers: IVUS and OCT results of the DESTINY trial.

    PubMed

    Costa, J Ribamar; Chamié, Daniel; Abizaid, Alexandre A C; Ribeiro, Expedito; Meireles, George C; Prudente, Maurício; Campos, Carlos A; Castro, Juliana P; Costa, Ricardo; Lemos, Pedro A

    2017-02-01

    We sought to compare, by means of IVUS and OCT imaging, the performance of a novel sirolimus-eluting drug-eluting stent (DES) with biodegradable polymer (Inspiron™) to the Biomatrix™ DES. From the DESTINY trial, a total of 70 randomized patients (2:1) were enrolled in the IVUS substudy (Inspiron™, n = 46; Biomatrix™: n = 20) while 25 patients were evaluated with OCT (Inspiron™, n = 19; Biomatrix™: n = 06) at 9-month follow-up. The main endpoints were % of neointimal tissue obstruction (IVUS) and neointimal stut coverage (OCT) at 9 months. Patients treated with both DES had very little NIH formation at 9 months either by IVUS (% of NIH obstruction of 4.9 ± 4.1 % with Inspiron™ vs. 2.7 ± 2.9 % with Biomatrix™, p = 0.03) or by OCT (neointimal thickness of 144.2 ± 72.5 µm Inspiron™ vs. 115.0 ± 53.9 µm with Biomatrix™, p = 0.45). Regarding OCT strut-level assessment, again both devices showed excellent 9-month performance, with high rates of strut coverage (99.49 ± 1.01 % with Inspiron™ vs. 97.62 ± 2.21 % with Biomatrix™, p < 0.001) and very rare malapposition (0.29 ± 1.06 % with Inspiron™ vs. 0.53 ± 0.82 % with Biomatrix™, p = 0.44). Patients with any uncovered struts were more frequently identified in the Biomatrix™ group (9.78 ± 7.13 vs. 2.29 ± 3.91 %, p < 0.001). In the present study, midterm IVUS and OCT evaluations showed that both new generation DES with biodegradable polymer were effective in terms of suppressing excessive neointimal response, with very high rates of apposed and covered struts, suggesting a consistent and benign healing pattern.

  16. Quantitative analysis of the side-branch orifice after bifurcation stenting using en-face processing of OCT images: a comparison between Xience V and Resolute Integrity stents.

    PubMed

    Minami, Yoshiyasu; Wang, Zhao; Aguirre, Aaron D; Lee, Stephen; Uemura, Shiro; Soeda, Tsunenari; Vergallo, Rocco; Raffel, Owen C; Barlis, Peter; Itoh, Tomonori; Lee, Hang; Fujimoto, James; Jang, Ik-Kyung

    2016-01-01

    Methods for intravascular assessment of the side-branch (SB) orifice after stenting are not readily available. The aim of this study was to assess the utility of an en-face projection processing for optical coherence tomography (OCT) images for SB evaluation. Measurements of the SB orifice obtained using en-face OCT images were validated using a phantom model. Linear regression modeling was applied to estimated area measurements made on the en-face images. The SB orifice was then analyzed in 88 patients with bifurcation lesions treated with either Xience V (everolimus-eluting stent) or Resolute Integrity [zotarolimus-eluting stent (ZES)]. The SB orifice area (A) and the area obstructed by struts (B) were calculated, and the %open area was evaluated as (A-B)/A*100. Linear regression modeling demonstrated that the observed departures of the intercept and slope were not significantly different from 0 (-0.12 ± 0.22, P=0.59) and 1 (1.01 ± 0.06, R(2)=0.88, P=0.87), respectively. In cases without SB dilatation, the %open area was significantly larger in the everolimus-eluting stent group (n=25) than in the ZES group [n=32; 89.2% (83.7-91.3) vs. 84.3% (78.9-87.8), P=0.04]. A significant difference in %open area between cases with and those without SB dilatation was demonstrated in the ZES group [91.4% (86.1-94.0) vs. 84.3% (78.9-87.8), P=0.04]. The accuracy of SB orifice measurement on an en-face OCT image was validated using a phantom model. This novel approach enables quantitative evaluation of the differences in SB orifice area free from struts among different stent types and different treatment strategies in vivo.

  17. 21 CFR 876.4620 - Ureteral stent.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ureteral stent. 876.4620 Section 876.4620 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4620 Ureteral stent. (a) Identification. A ureteral stent...

  18. Tracking delivery of a drug surrogate in the porcine heart using photoacoustic imaging and spectroscopy

    NASA Astrophysics Data System (ADS)

    Furdella, Kenneth J.; Witte, Russell S.; Vande Geest, Jonathan P.

    2017-04-01

    Although the drug-eluting stent (DES) has dramatically reduced the rate of coronary restenosis, it still occurs in up to 20% of patients with a DES. Monitoring drug delivery could be one way to decrease restenosis rates. We demonstrate real-time photoacoustic imaging and spectroscopy (PAIS) using a wavelength-tunable visible laser and clinical ultrasound scanner to track cardiac drug delivery. The photoacoustic signal was initially calibrated using porcine myocardial samples soaked with a known concentration of a drug surrogate (DiI). Next, an in situ coronary artery was perfused with DiI for 20 min and imaged to monitor dye transport in the tissue. Finally, a partially DiI-coated stent was inserted into the porcine brachiocephalic trunk for imaging. The photoacoustic signal was proportional to the DiI concentration between 2.4 and 120 μg/ml, and the dye was detected over 1.5 mm from the targeted coronary vessel. Photoacoustic imaging was also able to differentiate the DiI-coated portion of the stent from the uncoated region. These results suggest that PAIS can track drug delivery to cardiac tissue and detect drugs loaded onto a stent with sub-mm precision. Future work using PAIS may help improve DES design and reduce the probability of restenosis.

  19. Evaluation of clinical outcomes in patients undergoing dual vessel percutaneous coronary intervention using sirolimus-eluting coronary stent system in India.

    PubMed

    Chandwani, Prakash; Prajapati, Jayesh; Porwal, Sanjay; Khambhati, Bhavesh; Thakkar, Ashok

    2015-02-01

    Coronary artery disease is the most common catastrophic disease in India. The safety and effectiveness of dual vessel sirolimus-eluting stent (SES) implantation (used as an intervention in CAD) is currently unknown in Indian population. The purpose of this study was to investigate one year clinical outcomes of patients with dual vessel coronary artery disease after implantation of the Supralimus-Core SES, in a "real-world" setting. We evaluated 60 patients between April-2011 and August-2012, who underwent dual vessel percutaneous coronary intervention (PCI) with the Supralimus-Core SES implantation at the same index procedure. Dual vessels were defined as involvement of two major epicardial vessels (right, left anterior descending, circumflex, or left main coronary arteries) or one major epicardial vessel and a branch (≥2.5 mm in diameter) originating from another major epicardial vessel. The primary endpoint was target lesion failure (TLF) defined as the composite of cardiac death, myocardial infarction (MI), and clinically-driven target lesion revascularization (TLR) at one year. Secondary endpoint included combined (definite, probable and possible) stent thrombosis (ST). A total of 120 lesions were treated in 60 enrolled patients (mean age 56.0±9.2 y; 80.0% male) with average stent length of 23.1±8.5 mm. Among 60 patients, diabetes, hypertension and hypercholesterolemia were present in 15 (25.0%), 22 (36.7%) and 25 (41.7%) patients respectively. Indications for PCI were unstable angina in 30 (50.0%) patients and stable angina in 11 (18.3%) patients. Overall, 40 (33.3%) lesions were classified as complex (American College of Cardiology/American Heart Association type B2/C). The cumulative TLF rate was 5.0% (n=3) at one year. Cardiac death, MI and clinically-driven TLR occurred in 1 (1.7%), 0 (0%) and 2 (3.3%) patients, respectively at one year follow-up. The Kaplan-Meier curve of the freedom from overall events at one year was 95.0%. According to the Academic

  20. 21 CFR 884.3900 - Vaginal stent.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vaginal stent. 884.3900 Section 884.3900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES... stent. (a) Identification. A vaginal stent is a device used to enlarge the vagina by stretching, or to...

  1. Can the optimal type of stent be predicted based on clinical risk factors? A subgroup analysis of the randomized BASKET-PROVE trial.

    PubMed

    Vassalli, Giuseppe; Klersy, Catherine; De Servi, Stefano; Galatius, Soeren; Erne, Paul; Eberli, Franz; Rickli, Hans; Hornig, Burkhard; Bertel, Osmund; Bonetti, Piero; Moccetti, Tiziano; Kaiser, Christoph; Pfisterer, Matthias; Pedrazzini, Giovanni

    2016-03-01

    The randomized BASKET-PROVE study showed no significant differences between sirolimus-eluting stents (SES), everolimus-eluting stents (EES), and bare-metal stents (BMS) with respect to the primary end point, rates of death from cardiac causes, or myocardial infarction (MI) at 2 years of follow-up, in patients requiring stenting of a large coronary artery. Clinical risk factors may affect clinical outcomes after percutaneous coronary interventions. We present a retrospective analysis of the BASKET-PROVE data addressing the question as to whether the optimal type of stent can be predicted based on a cumulative clinical risk score. A total of 2,314 patients (mean age 66 years) who underwent coronary angioplasty and implantation of ≥1 stents that were ≥3.0 mm in diameter were randomly assigned to receive SES, EES, or BMS. A cumulative clinical risk score was derived using a Cox model that included age, gender, cardiovascular risk factors (hypercholesterolemia, hypertension, family history of cardiovascular disease, diabetes, smoking), presence of ≥2 comorbidities (stroke, peripheral artery disease, chronic kidney disease, chronic rheumatic disease), a history of MI or coronary revascularization, and clinical presentation (stable angina, unstable angina, ST-segment elevation MI). An aggregate drug-eluting stent (DES) group (n = 1,549) comprising 775 patients receiving SES and 774 patients receiving EES was compared to 765 patients receiving BMS. Rates of death from cardiac causes or nonfatal MI at 2 years of follow-up were significantly increased in patients who were in the high tertile of risk stratification for the clinical risk score compared to those who were in the aggregate low-mid tertiles. In patients with a high clinical risk score, rates of death from cardiac causes or nonfatal MI were lower in patients receiving DES (2.4 per 100 person-years, 95% CI 1.6-3.6) compared with BMS (5.5 per 100 person-years, 95% CI 3.7-8.2, hazard ratio 0.45, 95% CI 0

  2. Design of the exhale airway stents for emphysema (EASE) trial: an endoscopic procedure for reducing hyperinflation

    PubMed Central

    2011-01-01

    Background Airway Bypass is a catheter-based, bronchoscopic procedure in which new passageways are created that bypass the collapsed airways, enabling trapped air to exit the lungs. The Exhale Airway Stents for Emphysema (EASE) Trial was designed to investigate whether Exhale® Drug-Eluting Stents, placed in new passageways in the lungs, can improve pulmonary function and reduce breathlessness in severely hyperinflated, homogeneous emphysema patients (NCT00391612). Methods/Design The multi-center, randomized, double-blind, sham-controlled trial design was posted on http://www.clinicaltrials.gov in October 2006. Because Bayesian statistics are used for the analysis, the proposed enrollment ranged from 225 up to 450 subjects at up to 45 institutions. Inclusion criteria are: high resolution CT scan with evidence of homogeneous emphysema, post-bronchodilator pulmonary function tests showing: a ratio of FEV1/FVC < 70%, FEV1≤50% of predicted or FEV1 < 1 liter, RV/TLC≥0.65 at screening, marked dyspnea score ≥2 on the modified Medical Research Council scale of 0-4, a smoking history of at least 20 pack years and stopped smoking for at least 8 weeks prior to enrollment. Following 16 to 20 supervised pulmonary rehabilitation sessions, subjects were randomized 2:1 to receive either a treatment (Exhale® Drug-Eluting Stent) or a sham bronchoscopy. A responder analysis will evaluate the co-primary endpoints of an FVC improvement ≥12% of the patient baseline value and modified Medical Research Council dyspnea scale improvement (reduction) ≥1 point at the 6-month follow-up visit. Discussion If through the EASE Trial, Airway Bypass is shown to improve pulmonary function and reduce dyspnea while demonstrating an acceptable safety profile, then homogeneous patients will have a minimally invasive treatment option with meaningful clinical benefit. Trial Registration ClinicalTrials.gov: NCT00391612 PMID:21214899

  3. [Community types, phenology and propagation characteristics of Taxus mairei in north Guangdong].

    PubMed

    Liao, Wenbo; Zhang, Zhiqian; Chen, Zhiming; Tang, Changgen; Deng, Shifu

    2002-07-01

    Community types, phenology and propagation characteristics of Taxus mairei in north Guangdong were studied. The results showed that in north Guangdong province, Taxus mairei mainly distributed in the typical ever-green broad-leaf forest of lower and mid-subtropics dispersedly. Terminal bud of Taxus mairei was formed in late October and begun to grow foliages in mid-April, male flower bud was appeared in mid-May and the efflorescence was from late July to late November, female flower bud was formed in late August and the efflorescence was from late October to late January of second year, and the fruit mature period was in early October of second year. Under natural condition, the seed germination needed 2-3 years. Under experimental condition, the germination rate could be up to 82.2%. The effect of cuttage was better by taking mature annual twig and pretreatment by ABT1(100 mg.L-1) from October to November every year, and the rooting rate could be up to 95%.

  4. Long-Term Effectiveness of the Zilver PTX Drug-Eluting Stent for Femoropopliteal Peripheral Artery Disease in Patients with No Patent Tibial Runoff Vessels-Results from the Zilver PTX Japan Post-Market Surveillance Study.

    PubMed

    Cipollari, Stefano; Yokoi, Hiroyoshi; Ohki, Takao; Kichikawa, Kimihiko; Nakamura, Masato; Komori, Kimihiro; Nanto, Shinsuke; O'Leary, Erin E; Lottes, Aaron E; Saunders, Alan T; Dake, Michael D

    2018-01-01

    To evaluate 2-year results of the Zilver PTX (Cook Medical, Bloomington, Indiana) drug-eluting stent (DES) for femoropopliteal peripheral artery disease (PAD) in patients with no continuous patent infrapopliteal runoff arteries compared with patients with ≥ 1 continuous patent runoff vessels. A retrospective analysis of patients with femoropopliteal PAD enrolled in the Zilver PTX Post-Market Surveillance Study in Japan was performed. There were no exclusion criteria. Outcomes, including freedom from target lesion revascularization (TLR), patency, and clinical benefit, for the no-runoff group (n = 54) were compared with the runoff group (n = 846). The 2 groups were similar in terms of demographics, lesion characteristics, and comorbidities (P > .05). There was a higher incidence of critical limb ischemia in the no-runoff group compared with the runoff group (44.8% vs 19.7%; P < .01). There were 3 amputations (5.6%) in the no-runoff group versus 7 amputations (0.8%) in the runoff group (P = .02). At 2 years, freedom from TLR rates were 81.3% versus 83.8% (P = .87), patency rates were 68.4% versus 70.7% (P = .95), and clinical benefit rates were 73.7% versus 80.0% (P = .16) in the no-runoff versus runoff group, respectively. Results in patients with no continuous patent tibial runoff were favorable through 2 years and similar to results for patients with ≥ 1 continuous patent runoff vessels, indicating that the Zilver PTX DES may be a valid treatment option for patients with these difficult-to-treat lesions. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  5. Impact of anaemia on long-term outcomes in patients treated with first- and second-generation drug-eluting stents; Katowice-Zabrze Registry.

    PubMed

    Wańha, Wojciech; Kawecki, Damian; Roleder, Tomasz; Pluta, Aleksandra; Marcinkiewicz, Kamil; Dola, Janusz; Morawiec, Beata; Krzych, Łukasz; Pawłowski, Tomasz; Smolka, Grzegorz; Ochała, Andrzej; Nowalany-Kozielska, Ewa; Tendera, Michał; Wojakowski, Wojciech

    2016-01-01

    Coexisting anaemia is associated with an increased risk of major adverse cardiac and cerebrovascular events (MACCE) and bleeding complications after percutaneous coronary intervention (PCI), especially in patients with acute coronary syndrome. To assess the impact of anaemia in patients with coronary artery disease (CAD) treated with first- and second-generation drug-eluting stents (DES) on one-year MACCE. The registry included 1916 consecutive patients (UA: n = 1502, 78.3%; NSTEMI: n = 283, 14.7%; STEMI/LBBB: n = 131, 6.8%) treated either with first- (34%) or second-generation (66%) DES. The study population was divided into two groups: patients presenting with anaemia 217 (11%) and without anaemia 1699 (89%) prior to PCI. Anaemia was defined according to World Heart Organisation (haemoglobin [Hb] level < 13 g/dL for men and < 12 g/dL for women). Patients with anaemia were older (69, IQR: 61-75 vs. 62, IQR: 56-70, p < 0.001), had higher prevalence of co-morbidities: diabetes (44.7% vs. 36.4%, p = 0.020), chronic kidney disease (31.3% vs. 19.4%; p < 0.001), peripheral artery disease (10.1% vs. 5.4%, p = 0.005), and lower left ventricular ejection fraction values (50, IQR: 40-57% vs. 55, IQR: 45-60%; p < 0.001). No difference between gender in frequency of anaemia was found. Patients with anaemia more often had prior myocardial infarction (MI) (57.6% vs. 46.4%; p = 0.002) and coronary artery bypass grafting (31.3% vs. 19.4%; p < 0.001) in comparison to patients without anaemia. They also more often had multivessel disease in angiography (36.4% vs. 26.1%; p = 0.001) and more complexity CAD as measured by SYNTAX score (21, IQR: 12-27 points vs. 14, IQR: 8-22 points; p = 0.001). In-hospital risk of acute heart failure (2.7% vs. 0.7%; p = 0.006) and bleeding requiring transfusion (3.2% vs. 0.5%; p < 0.001) was significantly higher in patients with anaemia. One-year follow-up showed that there was higher rate of death in patients with anaemia. However, there were no

  6. Shrinking the Supply Chain for Implantable Coronary Stent Devices.

    PubMed

    Moore, Sean S; O'Sullivan, Kevin J; Verdecchia, Francesco

    2016-02-01

    Stenting treatments for the management of disease in the heart, arterial and venous systems, biliary ducts, urethras, ureters, oesophageal tract and prostate have made enormous technical advances since their introduction into clinical use. The progression from metallic to polymer based bio-absorbable stents, coupled with the advances in additive manufacturing techniques, present a unique opportunity to completely re-envision the design, manufacture, and supply chain of stents. This paper looks at current stenting trends and proposes a future where the stent supply chain is condensed from ~150 days to ~20 min. The Cardiologist therefore has the opportunity to become a designer, manufacturer and user with patients receiving custom stents specific to their unique pathology that will be generated, delivered and deployed in the Cath-lab. The paper will outline this potentially revolutionary development and consider the technical challenges that will need to be overcome in order to achieve these ambitious goals. A high level overview of the generating eluting stents in situ program-GENESIS-is outlined including some early experimental work.

  7. Climate warming and the decline of Taxus airborne pollen in urban pollen rain (Emilia Romagna, northern Italy).

    PubMed

    Mercuri, A M; Torri, P; Casini, E; Olmi, L

    2013-01-01

    Woody plant performance in a changing global environment has always been at the centre of palaeoenvironmental and long-term climate reconstructions carried out by means of pollen analysis. In Mediterranean regions, Taxus constitutes the highest percentage in past pollen diagrams from cold or cool periods, and therefore it is generally considered a good index to infer climate features from past records. However, a comparison of these inferences with the true current trends in pollen production has not been attemped until now. This study reports the decline of airborne pollen of Taxus observed in Emilia Romagna, a region of northern Italy, during the period 1990-2007. Phenological observations on four male specimens and microscopic examination of fresh pollen were made in order to check Taxus flowering time and pollen morphology. Airborne pollen was monitored through continuous sampling with a Hirst volumetric sampler. In the 18-year long period of investigation, Taxus pollen production has decreased, while total woody pollen abundance in air has increased. The trend of the Taxus pollen season shows a delay at the beginning, a shortening of the pollen period, and an advance of the end of the pollen season. This was interpreted as a response to climate warming. In particular, Taxus follows the behaviour of winter-flowering plants, and therefore earlier pollination is favoured at low autumn temperatures, while late pollination occurs more often, most likely after warm autumn temperatures. © 2012 German Botanical Society and The Royal Botanical Society of the Netherlands.

  8. Causes of Death Following PCI Versus CABG in Complex CAD: 5-Year Follow-Up of SYNTAX.

    PubMed

    Milojevic, Milan; Head, Stuart J; Parasca, Catalina A; Serruys, Patrick W; Mohr, Friedrich W; Morice, Marie-Claude; Mack, Michael J; Ståhle, Elisabeth; Feldman, Ted E; Dawkins, Keith D; Colombo, Antonio; Kappetein, A Pieter; Holmes, David R

    2016-01-05

    There are no data available on specific causes of death from randomized trials that have compared coronary artery bypass grafting (CABG) with percutaneous coronary intervention (PCI). The purpose of this study was to investigate specific causes of death, and its predictors, after revascularization for complex coronary disease in patients. An independent Clinical Events Committee consisting of expert physicians who were blinded to the study treatment subclassified causes of death as cardiovascular (cardiac and vascular), noncardiovascular, or undetermined according to the trial protocol. Cardiac deaths were classified as sudden cardiac, related to myocardial infarction (MI), and other cardiac deaths. In the randomized cohort, there were 97 deaths after CABG and 123 deaths after PCI during a 5-year follow-up. After CABG, 49.4% of deaths were cardiovascular, with the greatest cause being heart failure, arrhythmia, or other causes (24.6%), whereas after PCI, the majority of deaths were cardiovascular (67.5%) and as a result of MI (29.3%). The cumulative incidence rates of all-cause death were not significantly different between CABG and PCI (11.4% vs. 13.9%, respectively; p = 0.10), whereas there were significant differences in terms of cardiovascular (5.8% vs. 9.6%, respectively; p = 0.008) and cardiac death (5.3% vs. 9.0%, respectively; p = 0.003), which were caused primarily by a reduction in MI-related death with CABG compared with PCI (0.4% vs. 4.1%, respectively; p <0.0001). Treatment with PCI versus CABG was an independent predictor of cardiac death (hazard ratio: 1.55; 95% confidence interval: 1.09 to 2.33; p = 0.045). The difference in MI-related death was seen largely in patients with diabetes, 3-vessel disease, or high SYNTAX (TAXUS Drug-Eluting Stent Versus Coronary Artery Bypass Surgery for the Treatment of Narrowed Arteries) trial scores. During a 5-year follow-up, CABG in comparison with PCI was associated with a significantly reduced rate of MI

  9. Stent thrombosis and restenosis: what have we learned and where are we going? The Andreas Grüntzig Lecture ESC 2014

    PubMed Central

    Byrne, Robert A.; Joner, Michael; Kastrati, Adnan

    2015-01-01

    Modern-day stenting procedures leverage advances in pharmacotherapy and device innovation. Patients treated with contemporary antiplatelet agents, peri-procedural antithrombin therapy and new-generation drug-eluting stents (DES) have excellent outcomes over the short to medium term. Indeed, coupled with the reducing costs of these devices in most countries there remain very few indications where patients should be denied treatment with standard-of-care DES therapy. The two major causes of stent failure are stent thrombosis (ST) and in-stent restenosis (ISR). The incidence of both has reduced considerably in recent years. Current clinical registries and randomized trials with broad inclusion criteria show rates of ST at or <1% after 1 year and ∼0.2–0.4% per year thereafter; rates of clinical ISR are 5% respectively. Angiographic surveillance studies in large cohorts show rates of angiographic ISR of ∼10% with new-generation DES. The advent of high-resolution intracoronary imaging has shown that in many cases of late stent failure neoatherosclerotic change within the stented segment represents a final common pathway for both thrombotic and restenotic events. In future, a better understanding of the pathogenesis of this process may translate into improved late outcomes. Moreover, the predominance of non-stent-related disease as a cause of subsequent myocardial infarction during follow-up highlights the importance of lifestyle and pharmacological interventions targeted at modification of the underlying disease process. Finally, although recent developments focus on strategies which circumvent the need for chronically indwelling stents—such as drug-coated balloons or fully bioresorbable stents—more data are needed before the wider use of these therapies can be advocated. PMID:26417060

  10. Safety of 6-month duration of dual antiplatelet therapy after percutaneous coronary intervention in patients with acute coronary syndromes: Rationale and design of the Smart Angioplasty Research Team-safety of 6-month duration of Dual Antiplatelet Therapy after percutaneous coronary intervention in patients with acute coronary syndromes (SMART-DATE) prospective multicenter randomized trial.

    PubMed

    Lee, Joo Myung; Cho, Deok-Kyu; Hahn, Joo-Yong; Song, Young Bin; Park, Taek Kyu; Oh, Ju-Hyeon; Lee, Jin Bae; Doh, Joon-Hyung; Kim, Sang-Hyun; Yang, Jeong Hoon; Choi, Jin-Ho; Choi, Seung-Hyuck; Lee, Sang Hoon; Gwon, Hyeon-Cheol

    2016-12-01

    Dual antiplatelet therapy (DAPT) is a fundamental treatment that optimizes clinical outcomes after percutaneous coronary intervention, especially in patients with acute coronary syndrome (ACS). Although current international guidelines recommend DAPT for at least 12 months after implantation of a drug-eluting stent in patients with ACS, these recommendations are not based on randomized controlled trials dedicated to ACS population. The SMART-DATE trial is a prospective, multicenter, randomized, and open-label study to demonstrate the noninferiority of 6-month DAPT compared with 12 months or longer DAPT in patients with ACS undergoing percutaneous coronary intervention. A total of 2,700 patients will undergo prospective, random assignment to either of the DAPT duration groups. To minimize the bias from different stent devices, the type of stents will be randomly assigned (everolimus-eluting stents, zotarolimus-eluting stents, or biolimus A9-eluting stents). The primary end point is a composite of all-cause death, myocardial infarction, and cerebrovascular events at 18 months after the index procedure. The major secondary end points are definite/probable stent thrombosis defined by the Academic Research Consortium and bleeding defined by Bleeding Academic Research Consortium type 2-5. The SMART-DATE randomized trial is the first study exploring the safety of 6-month DAPT compared with conventional 12-month or longer DAPT dedicated to patients with ACS after second-generation drug-eluting stent implantation. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Assessment of In-Stent Restenosis Using 64-MDCT: Analysis of the CORE-64 Multicenter International Trial

    PubMed Central

    Wykrzykowska, Joanna J.; Arbab-Zadeh, Armin; Godoy, Gustavo; Miller, Julie M.; Lin, Shezhang; Vavere, Andrea; Paul, Narinder; Niinuma, Hiroyuki; Hoe, John; Brinker, Jeffrey; Khosa, Faisal; Sarwar, Sheryar; Lima, Joao; Clouse, Melvin E.

    2012-01-01

    OBJECTIVE Evaluations of stents by MDCT from studies performed at single centers have yielded variable results with a high proportion of unassessable stents. The purpose of this study was to evaluate the accuracy of 64-MDCT angiography (MDCTA) in identifying in-stent restenosis in a multicenter trial. MATERIALS AND METHODS The Coronary Evaluation Using Multidetector Spiral Computed Tomography Angiography Using 64 Detectors (CORE-64) Multicenter Trial and Registry evaluated the accuracy of 64-MDCTA in assessing 405 patients referred for coronary angiography. A total of 75 stents in 52 patients were assessed: 48 of 75 stents (64%) in 36 of 52 patients (69%) could be evaluated. The prevalence of in-stent restenosis by quantitative coronary angiography (QCA) in this subgroup was 23% (17/75). Eighty percent of the stents were ≤ 3.0 mm in diameter. RESULTS The overall sensitivity, specificity, positive predictive value, and negative predictive value to detect 50% in-stent stenosis visually using MDCT compared with QCA was 33.3%, 91.7%, 57.1%, and 80.5%, respectively, with an overall accuracy of 77.1% for the 48 assessable stents. The ability to evaluate stents on MDCTA varied by stent type: Thick-strut stents such as Bx Velocity were assessable in 50% of the cases; Cypher, 62.5% of the cases; and thinner-strut stents such as Taxus, 75% of the cases. We performed quantitative assessment of in-stent contrast attenuation in Hounsfield units and correlated that value with the quantitative percentage of stenosis by QCA. The correlation coefficient between the average attenuation decrease and ≥ 50% stenosis by QCA was 0.25 (p = 0.073). Quantitative assessment failed to improve the accuracy of MDCT over qualitative assessment. CONCLUSION The results of our study showed that 64-MDCT has poor ability to detect in-stent restenosis in small-diameter stents. Evaluability and negative predictive value were better in large-diameter stents. Thus, 64-MDCT may be appropriate for

  12. Long-term forecasting and comparison of mortality in the Evaluation of the Xience Everolimus Eluting Stent vs. Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization (EXCEL) trial: prospective validation of the SYNTAX Score II.

    PubMed

    Campos, Carlos M; van Klaveren, David; Farooq, Vasim; Simonton, Charles A; Kappetein, Arie-Pieter; Sabik, Joseph F; Steyerberg, Ewout W; Stone, Gregg W; Serruys, Patrick W

    2015-05-21

    To prospectively validate the SYNTAX Score II and forecast the outcomes of the randomized Evaluation of the Xience Everolimus-Eluting Stent Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization (EXCEL) Trial. Evaluation of the Xience Everolimus Eluting Stent vs. Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization is a prospective, randomized multicenter trial designed to establish the efficacy and safety of percutaneous coronary intervention (PCI) with the everolimus-eluting stent compared with coronary artery bypass graft (CABG) surgery in subjects with unprotected left-main coronary artery (ULMCA) disease and low-intermediate anatomical SYNTAX scores (<33). After completion of patient recruitment in EXCEL, the SYNTAX Score II was prospectively applied to predict 4-year mortality in the CABG and PCI arms. The 95% prediction intervals (PIs) for mortality were computed using simulation with bootstrap resampling (10 000 times). For the entire study cohort, the 4-year predicted mortalities were 8.5 and 10.5% in the PCI and CABG arms, respectively [odds ratios (OR) 0.79; 95% PI 0.43-1.50). In subjects with low (≤22) anatomical SYNTAX scores, the predicted OR was 0.69 (95% PI 0.34-1.45); in intermediate anatomical SYNTAX scores (23-32), the predicted OR was 0.93 (95% PI 0.53-1.62). Based on 4-year mortality predictions in EXCEL, clinical characteristics shifted long-term mortality predictions either in favour of PCI (older age, male gender and COPD) or CABG (younger age, lower creatinine clearance, female gender, reduced left ventricular ejection fraction). The SYNTAX Score II indicates at least an equipoise for long-term mortality between CABG and PCI in subjects with ULMCA disease up to an intermediate anatomical complexity. Both anatomical and clinical characteristics had a clear impact on long-term mortality predictions and decision making between CABG and PCI. Published on behalf of the European Society

  13. Development of SCoT-Based SCAR Marker for Rapid Authentication of Taxus Media.

    PubMed

    Hao, Juan; Jiao, Kaili; Yu, Chenliang; Guo, Hong; Zhu, Yujia; Yang, Xiao; Zhang, Siyang; Zhang, Lei; Feng, Shangguo; Song, Yaobin; Dong, Ming; Wang, Huizhong; Shen, Chenjia

    2018-06-01

    Taxus media is an important species in the family Taxaceae with high medicinal and commercial value. Overexploitation and illegal trade have led T. media to a severe threat of extinction. In addition, T. media and other Taxus species have similar morphological traits and are easily misidentified, particularly during the seedling stage. The purpose of this study is to develop a species-specific marker for T. media. Through a screening of 36 start codon targeted (SCoT) polymorphism primers, among 15 individuals of 4 Taxus species (T. media, T. chinensis, T. cuspidate and T. fuana), a clear species-specific DNA fragment (amplified by primer SCoT3) for T. media was identified. After isolation and sequencing, a DNA sequence with 530 bp was obtained. Based on this DNA fragment, a primer pair for the sequence-characterized amplified region marker was designed and named MHSF/MHSR. PCR analysis with primer pair MHSF/MHSR revealed a clear amplified band for all individuals of T. media but not for T. chinensis, T. cuspidate and T. fuana. Therefore, this marker can be used as a quick, efficient and reliable tool to identify T. media among other related Taxus species. The results of this study will lay an important foundation for the protection and management of T. media as a natural resource.

  14. Biodegradable drug-eluting nanofiber-enveloped implants for sustained release of high bactericidal concentrations of vancomycin and ceftazidime: in vitro and in vivo studies

    PubMed Central

    Hsu, Yung-Heng; Chen, Dave Wei-Chih; Tai, Chun-Der; Chou, Ying-Chao; Liu, Shih-Jung; Ueng, Steve Wen-Neng; Chan, Err-Cheng

    2014-01-01

    We developed biodegradable drug-eluting nanofiber-enveloped implants that provided sustained release of vancomycin and ceftazidime. To prepare the biodegradable nanofibrous membranes, poly(D,L)-lactide-co-glycolide and the antibiotics were first dissolved in 1,1,1,3,3,3-hexafluoro-2-propanol. They were electrospun into biodegradable drug-eluting membranes, which were then enveloped on the surface of stainless plates. An elution method and a high-performance liquid chromatography assay were employed to characterize the in vivo and in vitro release rates of the antibiotics from the nanofiber-enveloped plates. The results showed that the biodegradable nanofiber-enveloped plates released high concentrations of vancomycin and ceftazidime (well above the minimum inhibitory concentration) for more than 3 and 8 weeks in vitro and in vivo, respectively. A bacterial inhibition test was carried out to determine the relative activity of the released antibiotics. The bioactivity ranged from 25% to 100%. In addition, the serum creatinine level remained within the normal range, suggesting that the high vancomycin concentration did not affect renal function. By adopting the electrospinning technique, we will be able to manufacture biodegradable drug-eluting implants for the long-term drug delivery of different antibiotics. PMID:25246790

  15. Drug coated balloon in peripheral artery disease.

    PubMed

    Shanmugasundaram, Madhan; Murugapandian, Sangeetha; Truong, Huu Tam; Lotun, Kapildeo; Banerjee, Subhash

    2018-04-21

    Peripheral artery disease (PAD) is highly prevalent but is often underdiagnosed and undertreated. Lower extremity PAD can often be life style limiting. Revascularization in carefully selected lower extremity PAD patients improves symptoms and functional status. Surgical revascularization used to be the only available strategy, but in the recent years, endovascular strategies have gained popularity due to faster recovery times with low morbidity and mortality rates. Endovascular procedures have increased significantly in the United States in the past few years. That being said, higher restenosis rates and low long-term patency rates have been the limiting factors for this strategy. Drug eluting stents have been introduced to help with lowering restenosis, however lower extremity PAD involves long segment where the outcomes of stents are suboptimal. Also, the disease often crosses joint line that makes it less ideal for the stents. Drug coated balloons (DCB) have been introduced to improve patency rates following endovascular intervention for lower extremity PAD. They have gained popularity among endovascular specialists due to its ease of use and the concept of "leave nothing behind". This is a review of scientific evidence supporting DCB use in PAD. Published by Elsevier Inc.

  16. Frequency of Angina Pectoris After Percutaneous Coronary Intervention and the Effect of Metallic Stent Type.

    PubMed

    Gaglia, Michael A; Torguson, Rebecca; Lipinski, Michael J; Gai, Jiaxiang; Koifman, Edward; Kiramijyan, Sarkis; Negi, Smita; Rogers, Toby; Steinvil, Arie; Suddath, William O; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron

    2016-02-15

    Although metallic coronary stents significantly reduce angina pectoris compared with optimal medical therapy, angina after percutaneous coronary intervention (PCI) remains frequent. We, therefore, sought to compare the incidence of any angina during the 1 year after PCI among the spectrum of commercially available metallic stents. Metallic stent type was classified as bare metal stent, Cypher, Taxus Express, Xience V, Promus Element, and Resolute. The primary end point was patient-reported angina within 1 year of PCI. Multivariable logistic regression was performed to assess the independent association of stent type with any angina at 1 year. Overall, 8,804 patients were queried in regard to angina symptoms; 32.3% experienced angina at some point in the first year after PCI. Major adverse cardiovascular events, a composite of all-cause mortality, target vessel revascularization, and Q-wave myocardial infarction, increased with angina severity: 6.8% for patients without angina, 10.0% for patients with class 1 or 2 angina, and 19.7% for patients with class 3 or 4 angina (p <0.001 for trend). After multivariable adjustment, there was no significant association between stent type and angina at 1 year after PCI. Baseline Canadian Cardiovascular Society class 3 or 4 angina, history of coronary artery bypass grafting, and history of PCI were associated with a higher likelihood of angina at 1 year; increasing age, male gender, presentation with acute coronary syndrome, and higher stented length were associated with less angina. In conclusion, metallic stent type is not associated with the occurrence of angina at up to 1 year after PCI. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Provisional vs. two-stent technique for unprotected left main coronary artery disease after ten years follow up: A propensity matched analysis.

    PubMed

    D'Ascenzo, Fabrizio; Iannaccone, Mario; Giordana, Francesca; Chieffo, Alaide; Connor, Stephen O; Napp, L Christian; Chandran, SujaySubash; de la Torre Hernández, José María; Chen, Shao-Liang; Varbella, Ferdinando; Omedè, Pierluigi; Taha, Salma; Meliga, Emanuele; Kawamoto, Hiroyoshi; Montefusco, Antonio; Chong, Mervyn; Garot, Philippe; Sin, Lin; Gasparetto, Valeria; Abdirashid, Mohamed; Cerrato, Enrico; Biondi-Zoccai, Giuseppe; Gaita, Fiorenzo; Escaned, Javier; Hiddick Smith, David; Lefèvre, Thierry; Colombo, Antonio; Sheiban, Imad; Moretti, Claudio

    2016-05-15

    There is uncertainty on which stenting approach confers the best long-term outlook for unprotected left main (ULM) bifurcation disease. This is a non-randomized, retrospective study including all consecutive patients with 50% stenosis of the left main involving at least 1 of the arteries stemming from the left main treated with drug-eluting stents (DES) in 9 European centers between 2002 and 2004. Patients were divided into two groups: those treated with provisional stentings vs. those treated with two stent strategy. The outcomes of interest were 10-year rates of target lesion revascularization (TLR), major adverse cardiac events (MACE), and their components (cardiovascular death, myocardial infarction [MI], or repeat revascularization), along with stent thrombosis (ST). A total of 285 patients were included, 178 (62.5%) in the provisional stenting group and 87 (37.5%) in the two stent group. After 10 years, no differences in TLR were found at unadjusted analysis (19% vs 25%, p>0.05) nor after propensity score matching (25% vs 28%, p>0.05). Similar rates of MACE (60% vs 66%, p>0.05), death (34% vs 43%, p>0.05), MI (9% vs 14%, p>0.05) and ST were also disclosed at propensity-based analysis. Even after 10 year follow-up, patients treated with provisional stenting on left main showed comparable rates of target lesion revascularization compared to two stent strategy. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. Can you score with balloons to enhance outcomes after drug coated balloon angioplasty? Insights from the Paris DCB Registry for in-stent restenosis.

    PubMed

    Merat, Benoît; Waliszewski, Matthias; Dillinger, Guillaume; Henry, Patrick; Sideris, Georgios

    2018-06-01

    The objective of this study was to assess the 12-month clinical outcomes in patients with drug-eluting stent in-stent restenosis (DES-ISR) who were either pre-dilated with non-compliant balloons (NCBA) and with additional scoring balloons (NCBA + SBA) prior to drug coated balloon (DCB) angioplasty. This monocentric, retrospective study included patients with DES-ISR who were routinely treated over a 2-year time span. Patients with stable angina and documented ischemia or selected forms of unstable angina due to a culprit DES-ISR lesion were analyzed. The primary endpoint was the clinically driven target-lesion revascularization (TLR) rate at 12 months. Secondary endpoints included post-interventional lumen gain and late lumen loss (LLL) at 6 months. The 12-month TLR rates in 124 patients who underwent either NCBA + SBA or NCBA only group were not different (17.3%, 9/52 vs 11.6%, 8/69, P = 0.371) and low as compared to other comparable studies. The use of SBA led to equally high post minimal lumen diameters (MLD) in both treatment arms (NCBA 2.21 ± 0.33 vs NCBA + SBA 2.18 ± 0.41, P = 0.868). We did not find a significant difference in late lumen loss (LLL) between both groups (0.50 ± 0.62 mm vs 0.40 ± 0.46 mm, P = 0.468). Scoring Balloon Angioplasty can safely and effectively prepare DES-ISR lesions to render them suitable for DCB angioplasty with acceptable TLR and MACE rates. © 2018, Wiley Periodicals, Inc.

  19. The first Taxus rhizosphere microbiome revealed by shotgun metagenomic sequencing.

    PubMed

    Hao, Da-Cheng; Zhang, Cai-Rong; Xiao, Pei-Gen

    2018-06-01

    In the present study, the shotgun high throughput metagenomic sequencing was implemented to globally capture the features of Taxus rhizosphere microbiome. Total reads could be assigned to 6925 species belonging to 113 bacteria phyla and 301 species of nine fungi phyla. For archaea and virus, 263 and 134 species were for the first time identified, respectively. More than 720,000 Unigenes were identified by clean reads assembly. The top five assigned phyla were Actinobacteria (363,941 Unigenes), Proteobacteria (182,053), Acidobacteria (44,527), Ascomycota (fungi; 18,267), and Chloroflexi (15,539). KEGG analysis predicted numerous functional genes; 7101 Unigenes belong to "Xenobiotics biodegradation and metabolism." A total of 12,040 Unigenes involved in defense mechanisms (e.g., xenobiotic metabolism) were annotated by eggNOG. Talaromyces addition could influence not only the diversity and structure of microbial communities of Taxus rhizosphere, but also the relative abundance of functional genes, including metabolic genes, antibiotic resistant genes, and genes involved in pathogen-host interaction, bacterial virulence, and bacterial secretion system. The structure and function of rhizosphere microbiome could be sensitive to non-native microbe addition, which could impact on the pollutant degradation. This study, complementary to the amplicon sequencing, more objectively reflects the native microbiome of Taxus rhizosphere and its response to environmental pressure, and lays a foundation for potential combination of phytoremediation and bioaugmentation. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Posterior reversible leukoencephalopathy syndrome secondary to hepatic transarterial chemoembolization with doxorubicin drug eluting beads

    PubMed Central

    Kistler, C. Andrew; McCall, Joseph Caleb; Ghumman, Saad Sultan; Ali, Ijlal Akbar

    2014-01-01

    Posterior reversible encephalopathy syndrome (PRES) is a rare complication of transarterial chemoembolization (TACE) used to treat liver metastases and has never been reported in a patient with metastatic uveal melanoma (UM) to the liver. We report the first case of PRES secondary to TACE with drug eluting beads (DEBs) loaded with doxorubicin in a 56-year-old woman with metastatic UM to the liver. PMID:24772346