Sample records for tc tracer technique

  1. [⁹⁹mTc]O₂-AMD3100 as a SPECT tracer for CXCR4 receptor imaging.

    PubMed

    Hartimath, Siddesh V; Domanska, Urszula M; Walenkamp, Annemiek M E; Rudi A J O, Dierckx; de Vries, Erik F J

    2013-05-01

    CXCR4 plays an important role in HIV infection, tumor progression, neurogenesis, and inflammation. In-vivo imaging of CXCR4 could provide more insight in the role of this receptor in health and disease. The aim of this study was to investigate [(99m)Tc]O₂-AMD3100 as a potential SPECT tracer for imaging of CXCR4. AMD3100 was labelled with [(99m)Tc]pertechnetate. A cysteine challenge assay was performed to test the tracer stability. Heterologous and homologous receptor binding assay and internalization assay were performed in CXCR4 expressing Jurkat-T cells. Ex vivo biodistribution was studied in healthy mice at 30, 60, and 120 min after tracer injection. Tumor uptake of the tracer was determined by microSPECT imaging in nude mice xenografted with human PC-3 prostate tumor. Specificity of tracer uptake was determined by blocking studies using an excess of unlabelled AMD3100. AMD3100 was labelled with technetium-99m with a radiochemical yield of >98%. The tracer was stable in PBS and mouse plasma for at least 6h at 37 °C. Heterologous and homologous binding assays with AMD3100 showed IC50 values of 240 ± 10 μM, and 92 ± 5 μM for [(125)I]SDF-1α and [(99m)Tc]O₂-AMD3100 respectively, with negligible receptor internalisation. The tracer showed high uptake in liver, lungs, spleen, thymus, intestine and bone. Blocking dose of AMD3100.8HCl (20mg/kg) decreased the uptake in these organs (p<0.05). [(99m)Tc]O2-AMD3100 showed specific tumor accumulation in mice bearing PC-3 xenografts model. Time activity curves (TAC) in AMD3100 pre-treated animals tracer showed 1.7 times less tumor uptake as compared to control animals (p<0.05). [(99m)Tc]O2-AMD3100 is readily labelled, is stable in plasma and displays a favourable binding affinity for the CXCR4 receptors. [(99m)Tc O₂-AMD3100 shows specific binding in organs with high CXCR4 expression and in CXCR4 positive tumors. These results justify further evaluation of this radiopharmaceutical as a potential biomarker for the

  2. Monoanionic 99mTc-tricarbonyl-aminopolycarboxylate complexes with uncharged pendant groups: Radiosynthesis and evaluation as potential renal tubular tracers.

    PubMed

    Lipowska, Malgorzata; Klenc, Jeffrey; Jarkas, Nashwa; Marzilli, Luigi G; Taylor, Andrew T

    2017-04-01

    99m Tc(CO) 3 -nitrilotriacetic acid, 99m Tc(CO) 3 (NTA), is a new renal tubular agent with pharmacokinetic properties comparable to those of 131 I-OIH but the clearance of 99m Tc(CO) 3 (NTA) and 131 I-OIH is still less than the clearance of PAH, the gold standard for the measurement of effective renal plasma flow. At physiological pH, dianionic 99m Tc(CO) 3 (NTA) has a mononegative inner metal-coordination sphere and a mononegative uncoordinated carboxyl group. To evaluate alternate synthetic approaches, we assessed the importance of an uncoordinated carboxyl group, long considered essential for tubular transport, by evaluating the pharmacokinetics of three analogs with the 99m Tc(CO) 3 (NTA) metal-coordination sphere but with uncharged pendant groups. 99m Tc(CO) 3 complexes with N-(2-acetamido)iminodiacetic acid (ADA), N-(2-hydroxyethyl)iminodiacetic acid (HDA) and N-(fluoroethyl)iminodiacetic acid (FEDA) were prepared using a tricarbonyl kit and isolated by HPLC. The pharmacokinetics were evaluated in Sprague-Dawley rats, with 131 I-OIH as an internal control; urine was analyzed for metabolites. Plasma protein binding and erythrocyte uptake were determined from the 10min blood samples. Re(CO) 3 (FEDA), the analog of 99m Tc(CO) 3 (FEDA), was prepared and characterized. 99m Tc(CO) 3 (ADA), 99m Tc(CO) 3 (HDA) and 99m Tc(CO) 3 (FEDA) were efficiently prepared as a single species with high radiochemical purities (>99%). These new monoanionic 99m Tc(CO) 3 tracers with uncharged dangling groups all showed rapid blood clearance and high specificity for renal excretion. Activity in the urine, as a percent of 131 I-OIH at 10 and 60min, was 96% and 99% for ADA, 96% and 100% for HDA, and 100% and 99% for FEDA, respectively. Each new tracer was excreted unchanged in the urine. The Re(CO) 3 (FEDA) structure adds compelling evidence that such 99m Tc(CO) 3 (NTA) analogs have metal-coordination spheres identical to that of 99m Tc(CO) 3 (NTA). New tracers lacking the negatively

  3. Initial Evaluation of (99m)Tc(CO)3(ASMA) as a Renal Tracer in Healthy Human Volunteers.

    PubMed

    Lipowska, Malgorzata; Klenc, Jeffrey; Folks, Russell D; Taylor, Andrew T

    2014-09-01

    Preclinical studies in rats showed that two of (99m)Tc(CO)3(ASMA) isomers (rac- and L-ASMA) had pharmacokinetic properties equivalent to that of (131)I-OIH, the radiopharmaceutical standard for the measurement of effective renal plasma flow. The aim of this study was to evaluate the pharmacokinetics of (99m)Tc(CO)3(ASMA) isomers in healthy human subjects. Three ASMA ligands (rac-, L- and D-ASMA) were labeled with (99m)Tc(CO)3 using an IsoLink kit (Covidien), and each formed (99m)Tc(CO)3(ASMA) tracer was co-injected with (131)I-OIH into healthy human subjects followed by sequential imaging, plasma clearance measurements and timed urine collection. Plasma protein binding, red cell uptake and percent injected dose in the urine were determined. Urine from each group of volunteers was analyzed for metabolites by HPLC. Image quality was excellent with all three agents. Each (99m)Tc(CO)3(ASMA) preparation was excreted unchanged in the urine. The plasma clearance ratio ((99m)Tc(CO)3(ASMA)/(131)I-OIH) was 81 ± 3 % for D-ASMA compared to only 20 ± 4 % for L-ASMA and 37 ± 7 % for rac-ASMA; the 81 % clearance ratio for D-ASMA isomer is still ∼ 30 % higher than the (99m)Tc-MAG3/(131)I-OIH clearance ratio (∼50-60 %). Red cell uptake was similar for all three tracers (6-9 %), and all tracers had a relatively rapid renal excretion; at 3 h, the (99m)Tc(CO)3(ASMA)/(131)I-OIH urine ratio was 100 ± 3 % for D-ASMA, 80 ± 2 % for L-ASMA and 88 ± 1 % for rac-ASMA. The renal excretion characteristics of (99m)Tc(CO)3(D-ASMA) in humans are superior to those of the other two (99m)Tc(CO)3(ASMA) isomers studied, but are still inferior to (131)I-OIH, even though there was no difference in the clearance of two of (99m)Tc(CO)3(ASMA) isomers and (131)I-OIH in rats. The work described here demonstrates the sensitivity in in vivo biological behavior of (99m)Tc(CO)3(ASMA) isomers to their subtle structural differences.

  4. Radionuclide imaging in herpes simplex encephalitis. [/sup 99m/Tc tracer techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karlin, C.A.; Robinson, R.G.; Hinthorn, D.R.

    1978-01-01

    Eight patients with herpes simplex encephalitis among the 10 cases diagnosed at the University of Kansas Medical Center from 1966 to 1976 were studied with /sup 99m/Tc early in their diagnostic work-up. The images were unilaterally positive in the temporal lobe area in all 8 patients. Radionuclide studies can suggest herpes simplex as the specific etiology in cases of encephalitis and can also indicate the best site for brain biopsy to confirm the diagnosis by fluorescent antibody techniques. Appropriate antiviral therapy should be instituted as soon as possible to alter the course of this destructive form of viral encephalitis.

  5. An evaluation of tracer dilution techniques for gauging of rivers in flood

    NASA Astrophysics Data System (ADS)

    Airey, P. L.; Calf, G. E.; Davison, A.; Easey, J. F.; Morley, A. W.

    1984-10-01

    The use of the tracer dilution technique to gauge flow over broad shallow floodplains is examined. Because of the long mixing lengths, it sometimes takes several days for the passage of the laterally dispersed pulse. Tracer methods can be used if the flow rates vary linearly during the passage of the pulse. The measured flow rate is related to the time at which the first moment of the concentration profile (∫ tc( z, t)d t) is zero. An experimental verification is presented. By analysing the tracer pulse shapes before the establishment of complete mixing, it was demonstrated that the effective dispersion coefficients were independent of the scale of turbulence over the range 10 m to ˜1 km. This is consistent with the establishment of isotropic turbulence on the floodplain in contrast to oceanic surfaces. The velocity of the tracer is a factor of 2 less than that of an advancing wave front, which is in acceptable agreement with prediction. It is concluded that the transport of a non-interacting contaminant across the floodplain can be predicted from the wave front velocity and the dispersion coefficients measured close to the release point.

  6. Monitoring Tc dynamics in a bioreduced sediment: an investigation with gamma camera imaging of (99m)Tc-pertechnetate and (99m)Tc-DTPA.

    PubMed

    Vandehey, Nicholas T; O'Neil, James P; Slowey, Aaron J; Boutchko, Rostyslav; Druhan, Jennifer L; Moses, William W; Nico, Peter S

    2012-11-20

    We demonstrate the utility of nuclear medical imaging technologies and a readily available radiotracer, [(99m)Tc]TcO(4)(-), for the noninvasive monitoring of Fe(II) production in acetate-stimulated sediments from Old Rifle, CO, USA. Microcosms consisting of sediment in artificial groundwater media amended with acetate were probed by repeated injection of radiotracer over three weeks. Gamma camera imaging was used to noninvasively quantify the rate and extent of [(99m)Tc]TcO(4)(-) partitioning from solution to sediment. Aqueous Fe(II) and sediment-associated Fe(II) were also measured and correlated with the observed tracer behavior. For each injection of tracer, curves of (99m)Tc concentration in solution vs time were fitted to an analytic function that accounts for both the observed rate of sedimentation as well as the rate of (99m)Tc association with the sediment. The rate and extent of (99m)Tc association with the biostimulated sediment correlated well with the production of Fe(II), and a mechanism of [(99m)Tc]TcO(4)(-) reduction via reaction with surface-bound Fe(II) to form an immobile Tc(IV) species was inferred. After three weeks of bioreduction, a subset of microcosms was aerated in order to reoxidize the Fe(II) to Fe(III), which also destroyed the affinity of the [(99m)Tc]TcO(4)(-) for the sediments. However, within 3 days postoxidation, the rate of Tc(VII) reduction was faster than immediately before oxidation implying a rapid return to more extensive bioreduction. Furthermore, aeration soon after a tracer injection showed that sediment-bound Tc(IV) is rapidly resolubilized to Tc(VII). In contrast to the [(99m)Tc]TcO(4)(-), a second commercially available tracer, (99m)Tc-DTPA (diethylenetriaminepentaacetic acid), had minimal association with sediment in both controls and biostimulated sediments. These experiments show the promise of [(99m)Tc]TcO(4)(-) and (99m)Tc-DTPA as noninvasive imaging probes for a redox-sensitive radiotracer and a conservative flow

  7. (99m)Tc(CO)3(NTA): a (99m)Tc renal tracer with pharmacokinetic properties comparable to those of (131)I-OIH in healthy volunteers.

    PubMed

    Taylor, Andrew T; Lipowska, Malgorzata; Marzilli, Luigi G

    2010-03-01

    Studies in rats showed that the pharmacokinetics of the tricarbonyl core radiopharmaceutical (99m)Tc(CO)(3)-nitrilotriacetic acid, (99m)Tc(CO)(3)(NTA), were essentially identical to those of (131)I ortho-iodohippuran ((131)I-OIH), the clinical gold standard for the measurement of effective renal plasma flow. Our objective was to compare the pharmacokinetics of these 2 tracers in healthy volunteers. (99m)Tc(CO)(3)(NTA) was prepared with commercially available NTA and a commercially available kit and isolated by reversed-phase high-performance liquid chromatography. Approximately 74 MBq (2 mCi) of (99m)Tc(CO)(3)(NTA) were coinjected with 9.25 MBq (250 microCi) of (131)I-OIH in 9 volunteers, and simultaneous imaging of each tracer was performed for 24 min. Plasma clearances were determined from 8 blood samples obtained 3-90 min after injection using the single-injection, 2-compartment model. Plasma protein binding, red cell uptake, and percentage injected dose in the urine at 30 and 180 min were determined. There was no difference in the plasma clearances of (99m)Tc(CO)(3)(NTA) and (131)I-OIH, 475 +/- 105 mL/min versus 472 +/- 108 mL/min, respectively. The plasma protein binding and red cell uptake of (99m)Tc(CO)(3)(NTA) were 43% +/- 5% and 9% +/- 6%, respectively; both values were significantly lower (P < 0.001) than the plasma protein binding (75% +/- 3%) and red cell uptake (17% +/- 5%) of (131)I-OIH. There was no significant difference in the percentage injected dose recovered in the urine at 30 min and at 3 h; for comparison, the percentage dose in the urine at 3 h was 91% +/- 4% for (99m)Tc(CO)(3)(NTA) and 91% +/- 6% for (131)I-OIH (P = 0.96). Image quality with (99m)Tc(CO)(3)(NTA) was excellent, and the renogram parameters were similar to those of (131)I-OIH. Preliminary results in healthy volunteers suggest that the pharmacokinetic behavior of (99m)Tc(CO)(3)(NTA) is comparable to that of (131)I-OIH.

  8. Application of separable parameter space techniques to multi-tracer PET compartment modeling.

    PubMed

    Zhang, Jeff L; Michael Morey, A; Kadrmas, Dan J

    2016-02-07

    Multi-tracer positron emission tomography (PET) can image two or more tracers in a single scan, characterizing multiple aspects of biological functions to provide new insights into many diseases. The technique uses dynamic imaging, resulting in time-activity curves that contain contributions from each tracer present. The process of separating and recovering separate images and/or imaging measures for each tracer requires the application of kinetic constraints, which are most commonly applied by fitting parallel compartment models for all tracers. Such multi-tracer compartment modeling presents challenging nonlinear fits in multiple dimensions. This work extends separable parameter space kinetic modeling techniques, previously developed for fitting single-tracer compartment models, to fitting multi-tracer compartment models. The multi-tracer compartment model solution equations were reformulated to maximally separate the linear and nonlinear aspects of the fitting problem, and separable least-squares techniques were applied to effectively reduce the dimensionality of the nonlinear fit. The benefits of the approach are then explored through a number of illustrative examples, including characterization of separable parameter space multi-tracer objective functions and demonstration of exhaustive search fits which guarantee the true global minimum to within arbitrary search precision. Iterative gradient-descent algorithms using Levenberg-Marquardt were also tested, demonstrating improved fitting speed and robustness as compared to corresponding fits using conventional model formulations. The proposed technique overcomes many of the challenges in fitting simultaneous multi-tracer PET compartment models.

  9. Application of separable parameter space techniques to multi-tracer PET compartment modeling

    PubMed Central

    Zhang, Jeff L; Morey, A Michael; Kadrmas, Dan J

    2016-01-01

    Multi-tracer positron emission tomography (PET) can image two or more tracers in a single scan, characterizing multiple aspects of biological functions to provide new insights into many diseases. The technique uses dynamic imaging, resulting in time-activity curves that contain contributions from each tracer present. The process of separating and recovering separate images and/or imaging measures for each tracer requires the application of kinetic constraints, which are most commonly applied by fitting parallel compartment models for all tracers. Such multi-tracer compartment modeling presents challenging nonlinear fits in multiple dimensions. This work extends separable parameter space kinetic modeling techniques, previously developed for fitting single-tracer compartment models, to fitting multi-tracer compartment models. The multi-tracer compartment model solution equations were reformulated to maximally separate the linear and nonlinear aspects of the fitting problem, and separable least-squares techniques were applied to effectively reduce the dimensionality of the nonlinear fit. The benefits of the approach are then explored through a number of illustrative examples, including characterization of separable parameter space multi-tracer objective functions and demonstration of exhaustive search fits which guarantee the true global minimum to within arbitrary search precision. Iterative gradient-descent algorithms using Levenberg–Marquardt were also tested, demonstrating improved fitting speed and robustness as compared to corresponding fits using conventional model formulations. The proposed technique overcomes many of the challenges in fitting simultaneous multi-tracer PET compartment models. PMID:26788888

  10. Application of separable parameter space techniques to multi-tracer PET compartment modeling

    NASA Astrophysics Data System (ADS)

    Zhang, Jeff L.; Morey, A. Michael; Kadrmas, Dan J.

    2016-02-01

    Multi-tracer positron emission tomography (PET) can image two or more tracers in a single scan, characterizing multiple aspects of biological functions to provide new insights into many diseases. The technique uses dynamic imaging, resulting in time-activity curves that contain contributions from each tracer present. The process of separating and recovering separate images and/or imaging measures for each tracer requires the application of kinetic constraints, which are most commonly applied by fitting parallel compartment models for all tracers. Such multi-tracer compartment modeling presents challenging nonlinear fits in multiple dimensions. This work extends separable parameter space kinetic modeling techniques, previously developed for fitting single-tracer compartment models, to fitting multi-tracer compartment models. The multi-tracer compartment model solution equations were reformulated to maximally separate the linear and nonlinear aspects of the fitting problem, and separable least-squares techniques were applied to effectively reduce the dimensionality of the nonlinear fit. The benefits of the approach are then explored through a number of illustrative examples, including characterization of separable parameter space multi-tracer objective functions and demonstration of exhaustive search fits which guarantee the true global minimum to within arbitrary search precision. Iterative gradient-descent algorithms using Levenberg-Marquardt were also tested, demonstrating improved fitting speed and robustness as compared to corresponding fits using conventional model formulations. The proposed technique overcomes many of the challenges in fitting simultaneous multi-tracer PET compartment models.

  11. Measurement of LNAPL flow using single-well tracer dilution techniques.

    PubMed

    Sale, Tom; Taylor, Geoffrey Ryan; Iltis, Gabriel; Lyverse, Mark

    2007-01-01

    This paper describes the use of single-well tracer dilution techniques to resolve the rate of light nonaqueous phase liquid (LNAPL) flow through wells and the adjacent geologic formation. Laboratory studies are presented in which a fluorescing tracer is added to LNAPL in wells. An in-well mixer keeps the tracer well mixed in the LNAPL. Tracer concentrations in LNAPL are measured through time using a fiber optic cable and a spectrometer. Results indicate that the rate of tracer depletion is proportional to the rate of LNAPL flow through the well and the adjacent formation. Tracer dilution methods are demonstrated for vertically averaged LNAPL Darcy velocities of 0.00048 to 0.11 m/d and LNAPL thicknesses of 9 to 24 cm. Over the range of conditions studied, results agree closely with steady-state LNAPL flow rates imposed by pumping. A key parameter for estimating LNAPL flow rates in the formation is the flow convergence factor alpha. Measured convergence factors for 0.030-inch wire wrap, 0.030-inch-slotted polyvinyl chloride (PVC), and 0.010-inch-slotted PVC are 1.7, 0.91, and 0.79, respectively. In addition, methods for using tracer dilution data to determine formation transmissivity to LNAPL are presented. Results suggest that single-well tracer dilution techniques are a viable approach for measuring in situ LNAPL flow and formation transmissivity to LNAPL.

  12. Advances in PET myocardial perfusion imaging: F-18 labeled tracers.

    PubMed

    Rischpler, Christoph; Park, Min-Jae; Fung, George S K; Javadi, Mehrbod; Tsui, Benjamin M W; Higuchi, Takahiro

    2012-01-01

    Coronary artery disease and its related cardiac disorders represent the most common cause of death in the USA and Western world. Despite advancements in treatment and accompanying improvements in outcome with current diagnostic and therapeutic modalities, it is the correct assignment of these diagnostic techniques and treatment options which are crucial. From a diagnostic standpoint, SPECT myocardial perfusion imaging (MPI) using traditional radiotracers like thallium-201 chloride, Tc-99m sestamibi or Tc-99m tetrofosmin is the most utilized imaging technique. However, PET MPI using N-13 ammonia, rubidium-82 chloride or O-15 water is increasing in availability and usage as a result of the growing number of medical centers with new-generation PET/CT systems taking advantage of the superior imaging properties of PET over SPECT. The routine clinical use of PET MPI is still limited, in part because of the short half-life of conventional PET MPI tracers. The disadvantages of these conventional PET tracers include expensive onsite production and inconvenient on-scanner tracer administration making them unsuitable for physical exercise stress imaging. Recently, two F-18 labeled radiotracers with longer radioactive half-lives than conventional PET imaging agents have been introduced. These are flurpiridaz F 18 (formerly known as F-18 BMS747158-02) and F-18 fluorobenzyltriphenylphosphonium. These longer half-life F-18 labeled perfusion tracers can overcome the production and protocol limitations of currently used radiotracers for PET MPI.

  13. Tc-99m TRODAT uptake in an osteoid tumor of clivus.

    PubMed

    Taywade, Sameer; Tripathi, Madhavi; Tandon, Vivek; Das, Chandan Jyoti; Damle, Nishikant Avinash; Shamim, Shamim Ahmed; Thukral, Parul; Bal, Chandrasekhar

    2016-01-01

    Tc-99m TRODAT is cocaine analog and binds to the dopamine transporter in vivo . Tc-99m TRODAT single-photon emission computed tomography/computed tomography. (SPECT/CT) is useful for demonstrating presynaptic dopaminergic dysfunction in patients with Parkinsonism. However, few reports have shown extrastriatal uptake of Tc-99m TRODAT. We present the case of a 67-year-old male who underwent Tc-99m TRODAT SPECT/CT for evaluation of Parkinsonism. In addition to tracer binding in the striatum, tracer uptake was noted in an osteoid tumor of the clivus. Integrated SPECT/CT enabled precise localization and characterization of the extrastriatal site of tracer binding and emphasizes the importance of such coincidental findings.

  14. Analysis techniques for tracer studies of oxidation. M. S. Thesis Final Report

    NASA Technical Reports Server (NTRS)

    Basu, S. N.

    1984-01-01

    Analysis techniques to obtain quantitative diffusion data from tracer concentration profiles were developed. Mass balance ideas were applied to determine the mechanism of oxide growth and to separate the fraction of inward and outward growth of oxide scales. The process of inward oxygen diffusion with exchange was theoretically modelled and the effect of lattice diffusivity, grain boundary diffusivity and grain size on the tracer concentration profile was studied. The development of the tracer concentration profile in a growing oxide scale was simulated. The double oxidation technique was applied to a FeCrAl-Zr alloy using 0-18 as a tracer. SIMS was used to obtain the tracer concentration profile. The formation of lacey oxide on the alloy was discussed. Careful consideration was given to the quality of data required to obtain quantitative information.

  15. LOW LEVEL COUNTING TECHNIQUES WITH SPECIAL REFERENCE TO BIOMEDICAL TRACER PROBLEMS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hosain, F.; Nag, B.D.

    1959-12-01

    Low-level counting techniques in tracer experiments are discussed with emphasis on the measurement of beta and gamma radiations with Geiger and scintillation counting methods. The basic principles of low-level counting are outlined. Screen-wall counters, internal gas counters, low-level beta counters, scintillation spectrometers, liquid scintillators, and big scintillation installations are described. Biomedical tracer investigations are discussed. Applications of low-level techniques in archaeological dating, biology, and other problems are listed. (M.C.G.)

  16. Standardization of Tc-99 by two methods and participation at the CCRI(II)-K2. Tc-99 comparison.

    PubMed

    Sahagia, M; Antohe, A; Ioan, R; Luca, A; Ivan, C

    2014-05-01

    The work accomplished within the participation at the 2012 key comparison of Tc-99 is presented. The solution was standardized for the first time in IFIN-HH by two methods: LSC-TDCR and 4π(PC)β-γ efficiency tracer. The methods are described and the results are compared. For the LSC-TDCR method, the program TDCR07c, written and provided by P. Cassette, was used for processing the measurement data. The results are 2.1% higher than when applying the TDCR06b program; the higher value, calculated with the software TDCR07c, was used for reporting the final result in the comparison. The tracer used for the 4π(PC)β-γ efficiency tracer method was a standard (60)Co solution. The sources were prepared from the mixture (60)Co+(99)Tc solution and a general extrapolation curve, type: N(βTc-99)/(M)(Tc-99)=f [1-ε(Co-60)], was drawn. This value was not used for the final result of the comparison. The difference between the values of activity concentration obtained by the two methods was within the limit of the combined standard uncertainty of the difference of these two results. © 2013 Published by Elsevier Ltd.

  17. Bone scanning in lymphoma. [/sup 99m/Tc tracer technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schechter, J.P.; Jones, S.E.; Woolfenden, J.M.

    1976-09-01

    The results of bone scanning with the newer technetium-99m complexes were correlated with clinical, laboratory, and radiographic findings in 26 patients with malignant lymphoma (10 with Hodgkin's disease and 16 with non-Hodgkin's lymphomas). Abnormalities on bone scan compatible with lymphomatous involvement of the skeleton appeared to occur more commonly in patients with diffuse lymphomas than in patients with nodular lymphomas and were generally observed in the setting of advanced disease (15 of 23 patients). Twenty-seven (73 percent) of the 37 scans obtained were abnormal. Although abnormal scans were observed with the greatest frequency in patients with bone pain (11 ofmore » 11), bone marrow involvement (11 of 12), abnormal skeletal radiographs (11 of 11), and elevated serum alkaline phosphatase levels (5 of 6), bone scanning also detected lymphomatous involvement in patients free of pain or with normal laboratory tests. Moreover, conventional radiography was entirely normal in six (35 percent) of 17 patients with abnormal scans and revealed only nonspecific osteopenia in another two patients (12 percent). Serial bone scans in nine patients reflected their response to chemotherapy. Of the 37 scans, only one was judged falsely positive and one falsely negative. Bone scanning with /sup 99m/Tc complexes is a safe, simple, and sensitive screening procedure for detecting both extensive and focal lymphomatous involvement of the skeletal system and is a useful means of following such involvement in response to treatment.« less

  18. Tracer techniques for urine volume determination and urine collection and sampling back-up system

    NASA Technical Reports Server (NTRS)

    Ramirez, R. V.

    1971-01-01

    The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.

  19. Preclinical Evaluation of RYM1, a Matrix Metalloproteinase-Targeted Tracer for Imaging Aneurysm.

    PubMed

    Toczek, Jakub; Ye, Yunpeng; Gona, Kiran; Kim, Hye-Yeong; Han, Jinah; Razavian, Mahmoud; Golestani, Reza; Zhang, Jiasheng; Wu, Terence L; Jung, Jae-Joon; Sadeghi, Mehran M

    2017-08-01

    Matrix metalloproteinases (MMPs) play a key role in abdominal aortic aneurysm (AAA) development. Accordingly, MMP-targeted imaging provides important information regarding vessel wall biology in the course of aneurysm development. Given the small size of the vessel wall and its proximity with blood, molecular imaging of aneurysm optimally requires highly sensitive tracers with rapid blood clearance. To this end, we developed a novel hydrosoluble zwitterionic MMP inhibitor, RYM, on the basis of which a pan-MMP tracer, RYM1, was designed. Here, we describe the development and preclinical evaluation of RYM1 in comparison with RP805, a commonly used pan-MMP tracer in murine models of aneurysm. Methods: The macrocyclic hydroxamate-based pan-MMP inhibitor coupled with 6-hydrazinonicotinamide, RYM1, was synthesized and labeled with 99m Tc. Radiochemical stability of 99m Tc-RYM1 was evaluated by radio-high-performance liquid chromatography analysis. Tracer blood kinetics and biodistribution were compared with 99m Tc-RP805 in C57BL/6J mice ( n = 10). 99m Tc-RYM1 binding to aneurysm and specificity were evaluated by quantitative autoradiography in apolipoprotein E-deficient (apoE -/- ) mice with CaCl 2 -induced carotid aneurysm ( n = 11). Angiotensin II-infused apoE -/- ( n = 16) mice were used for small-animal SPECT/CT imaging. Aortic tissue MMP activity and macrophage marker CD68 expression were assessed by zymography and reverse-transcription polymerase chain reaction. Results: RYM1 showed nanomolar range inhibition constants for several MMPs. 99m Tc-RYM1 was radiochemically stable in mouse blood for 5 h and demonstrated rapid renal clearance and lower blood levels in vivo compared with 99m Tc-RP805. 99m Tc-RYM1 binding to aneurysm and its specificity were shown by autoradiography in carotid aneurysm. Angiotensin II infusion in apoE -/- mice for 4 wk resulted in AAA formation in 36% (4/11) of surviving animals. In vivo 99m Tc-RYM1 small-animal SPECT/CT images showed

  20. Recent and ancient recharge deciphered by multi-dating tracer technique

    NASA Astrophysics Data System (ADS)

    Dogramaci, Shawan; Cook, Peter; Mccallum, Jimes; Purtchert, Roland

    2017-04-01

    Determining groundwater residence time from environmental tracer concentrations obtained from open bores or long screened intervals is fraught with difficulty because the sampled water represents variety of ages. Information on the distribution of groundwater age is commonly obtained by measuring more than one tracer. We examined the use of the multi-tracer technique representing different time frames (39Ar, 85Kr, 14C, 3H, CFC 11- CFC-12 CFC-113, SF6 and Cl,) to decipher the groundwater ages sampled from long screened bores in a regional aquifer in the Pilbara region of northwest Australia. We then applied a technique that assumes limited details of the form of the age distribution. Tracer concentrations suggest that groundwater samples are a mixture of young and old water - the former is inferred to represent localised recharge from an adjacent creek, and the latter to be diffuse recharge. Using our method, we were able to identify distinct age components in the groundwater. The results suggest the presence of four distinct age groups; zero and 20 years, 50 to 100 years, 100 to 600 years and approximately 1000 years old. These relatively high recharge events were consistent with local recharge sources (50-100 years) and confirmed by palaeo-climate record obtained from lake sediments. We found that although the ages of these components were well constrained, the relative proportions of each component was highly sensitive to errors of environmental tracer data. Our results show that the method we implemented can identify distinct age groups in groundwater samples without prior knowledge of the age distribution. The presence of distinct recharge times gives insight into groundwater flow conditions over long periods of time.

  1. The importance of Tc-MAA SPECT/CT for therapy planning of radioembolization in a patient treated with bevacizumab.

    PubMed

    Ahmadzadehfar, Hojjat; Sabet, Amir; Meyer, Carsten; Habibi, Elham; Biersack, Hans-Jürgen; Ezziddin, Samer

    2012-11-01

    A 76-year-old man with colorectal cancer and hepatic metastases was referred to us for radioembolization of the liver. Angiography with 99mTc-MAA SPECT/CT was performed 8 weeks after the discontinuation of bevacizumab. 99mTc-MAA SPECT/CT showed a diffused intrahepatic tracer distribution with no focally accentuated accumulation in the tumorous region. The test was repeated 6 weeks later and Tc-MAA SPECT/CT showed this time a tumor accentuated tracer accumulation in the liver. Subsequently, the patient was treated with resin microspheres. Tc-MAA SPECT/CT allows a better evaluation of intrahepatic tracer accumulation of Tc-MAA and facilitates the determination of the most appropriate treatment time.

  2. Somatostatin receptor scintigraphy using 99mTc-EDDA/HYNIC-TOC in patients with medullary thyroid carcinoma.

    PubMed

    Czepczyński, Rafał; Parisella, Maria Gemma; Kosowicz, Jerzy; Mikołajczak, Renata; Ziemnicka, Katarzyna; Gryczyńska, Maria; Sowiński, Jerzy; Signore, Alberto

    2007-10-01

    Several new somatostatin analogues have been developed for the diagnosis and therapy of different tumours. Since somatostatin receptors are often over-expressed in medullary thyroid carcinoma (MTC), the aim of our study was to evaluate the utility of scintigraphy with the somatostatin analogue (99m)Tc-EDDA/HYNIC-TOC in MTC in comparison with other diagnostic techniques. Forty-five patients with MTC, aged 14-83 years, were investigated. Scintigraphy using (99m)Tc-EDDA/HYNIC-TOC (Tektrotyd) was performed 2 and 4 h post injection of 740 MBq (20 mCi) of the tracer. Other imaging techniques were also applied and analysed in individual cases (ultrasonography, computed tomography, (99m)Tc(V)-DMSA, (131)I-MIBG, (99m)Tc-MDP, (111)In-DTPA-octreotide and (18)F-FDG-PET) and compared with (99m)Tc-EDDA/HYNIC-TOC. In group 1 (eight patients before thyroidectomy), uptake of the tracer was found in the primary tumours. In group 2 (six patients with remission), a false positive result was found in one patient; in the remaining five patients, no pathological foci were visualised. In group 3 (31 patients with post-surgical hypercalcitoninaemia), scintigraphy was true positive in 23 patients (74.2%): uptake in the thyroid bed was found in five patients, in the lymph nodes in 18 and in bone metastases in four. Using (99m)Tc-EDDA/HYNIC-TOC scintigraphy, the overall sensitivity was 79.5%, specificity 83.3%, accuracy 80.0%, positive predictive value 96.9% and negative predictive value 38.5%. (99m)Tc-EDDA/HYNIC-TOC is clinically useful for scintigraphy in the follow-up of patients with MTC. It can be used in clinical practice for preoperative evaluation, for localisation of local recurrence or distant metastases and particularly for therapy decision making.

  3. Bone marrow uptake of 99mTc-MIBI in patients with multiple myeloma.

    PubMed

    Fonti, R; Del Vecchio, S; Zannetti, A; De Renzo, A; Di Gennaro, F; Catalano, L; Califano, C; Pace, L; Rotoli, B; Salvatore, M

    2001-02-01

    In a previous study, we showed the ability of technetium-99m methoxyisobutylisonitrile (99mTc-MIBI) scan to identify active disease in patients with multiple myeloma (Eur J Nucl Med 1998; 25: 714-720). In particular, a semiquantitative score of the extension and intensity of bone marrow uptake was derived and correlated with both the clinical status of the disease and plasma cell bone marrow infiltration. In order to estimate quantitatively 99mTc-MIBI bone marrow uptake and to verify the intracellular localization of the tracer, bone marrow samples obtained from 24 multiple myeloma patients, three patients with monoclonal gammopathy of undetermined significance (MGUS) and two healthy donors were studied for in vitro uptake. After centrifugation over Ficoll-Hypaque gradient, cell suspensions were incubated with 99mTc-MIBI and the uptake was expressed as the percentage of radioactivity specifically retained within the cells. The cellular localization of the tracer was assessed by micro-autoradiography. Twenty-two out of 27 patients underwent 99mTc-MIBI scan within a week of bone marrow sampling. Whole-body images were obtained 10 min after intravenous injection of 555 MBq of the tracer; the extension and intensity of 99mTc-MIBI uptake were graded using the semiquantitative score. A statistically significant correlation was found between in vitro uptake of 99mTc-MIBI and both plasma cell infiltration (Pearson's coefficient of correlation r=0.69, P<0.0001) and in vivo score (Spearman rank correlation coefficient r=0.60, P<0.01). No specific tracer uptake was found in bone marrow samples obtained from the two healthy donors. Micro-autoradiography showed localization of 99mTc-MIBI inside the plasma cells infiltrating the bone marrow. Therefore, our findings show that the degree of tracer uptake both in vitro and in vivo is related to the percentage of infiltrating plasma cells which accumulate the tracer in their inner compartments.

  4. In vivo imaging of tumour angiogenesis in mice with the alpha(v)beta (3) integrin-targeted tracer 99mTc-RAFT-RGD.

    PubMed

    Sancey, Lucie; Ardisson, Valérie; Riou, Laurent M; Ahmadi, Mitra; Marti-Batlle, Danièle; Boturyn, Didier; Dumy, Pascal; Fagret, Daniel; Ghezzi, Catherine; Vuillez, Jean-Philippe

    2007-12-01

    The molecular imaging of tumour neoangiogenesis currently represents a major field of research for the diagnostic and treatment strategy of solid tumours. Endothelial cells from tumour neovessels overexpress the alpha(v)beta(3) integrin, which selectively binds to Arg-Gly-Asp (RGD)-containing peptides. We evaluated the potential of the novel radiotracer (99m)Tc-RAFT-RGD for the non-invasive molecular imaging of alpha(v)beta(3) integrin expression in mice models of tumour development. (99m)Tc-RAFT-RGD, (99m)Tc-cRGD (specific control) and (99m)Tc-RAFT-RAD (non-specific control) were injected intravenously to mice bearing B16F0 or TS/A-pc tumours. In vivo whole-body tomographic imaging and post-mortem biodistribution studies were performed 60 min following tracer injection. Adjacent tumour slices were used to compare the localisation of neovessels from immunostaining and the pattern of (99m)Tc-RAFT-RGD uptake from autoradiographic ex vivo imaging. Biodistribution studies indicated that (99m)Tc-RAFT-RGD tumour uptake was significantly higher than that of (99m)Tc-RAFT-RAD in B16F0 (2.4+/-0.5 vs 1.0+/-0.1%ID/g, respectively) and in TS/A-pc tumours (2.7+/-0.8 vs 0.7+/-0.1%ID/g, respectively). Immunohistochemical and autoradiographic studies indicated that (99m)Tc-RAFT-RGD intratumoural uptake preferentially occurred in angiogenic areas. Tomographic imaging allowed tumour visualisation following injection of (99m)Tc-RAFT-RGD and (99m)Tc-cRGD with similar tumour-to-contralateral muscle (T/CM) ratios in B16F0 and in TS/A-pc tumours whereas (99m)Tc-RAFT-RAD T/CM ratios did not allow tumour imaging. In accordance with the higher level of alpha(v)beta(3) integrin expression on TS/A-pc tumours than on B16F0 tumours as determined from western blot and immunoprecipitation analyses, the (99m)Tc-RAFT-RGD T/CM ratio was significantly higher in TS/A-pc than in B16F0 tumours. (99m)Tc-RAFT-RGD allowed the in vivo imaging of alpha(v)beta(3) integrin tumour expression.

  5. Reactive Tracer Techniques to Quantitatively Monitor Carbon Dioxide Storage in Geologic Formations

    NASA Astrophysics Data System (ADS)

    Matter, J. M.; Carson, C.; Stute, M.; Broecker, W. S.

    2012-12-01

    Injection of CO2 into geologic storage reservoirs induces fluid-rock reactions that may lead to the mineralization of the injected CO2. The long-term safety of geologic CO2 storage is, therefore, determined by in situ CO2-fluid-rock reactions. Currently existing monitoring and verification techniques for CO2 storage are insufficient to characterize the solubility and reactivity of the injected CO2, and to establish a mass balance of the stored CO2. Dissolved and chemically transformed CO2 thus avoid detection. We developed and are testing a new reactive tracer technique for quantitative monitoring and detection of dissolved and chemically transformed CO2 in geologic storage reservoirs. The technique involves tagging the injected carbon with radiocarbon (14C). Carbon-14 is a naturally occurring radioisotope produced by cosmic radiation and made artificially by 14N neutron capture. The ambient concentration is very low with a 14C/12C ratio of 10-12. The concentration of 14C in deep geologic formations and fossil fuels is at least two orders of magnitude lower. This makes 14C an ideal quantitative tracer for tagging underground injections of anthropogenic CO2. We are testing the feasibility of this tracer technique at the CarbFix pilot injection site in Iceland, where approximately 2,000 tons of CO2 dissolved in water are currently injected into a deep basalt aquifer. The injected CO2 is tagged with 14C by dynamically adding calibrated amounts of H14CO3 solution to the injection stream. The target concentration is 12 Bq/kg of injected water, which results in a 14C activity that is 5 times enriched compared to the 1850 background. In addition to 14C as a reactive tracer, trifluormethylsulphur pentafluoride (SF5CF3) and sulfurhexafluoride (SF6) are used as conservative tracers to monitor the transport of the injected CO2 in the subsurface. Fluid samples are collected for tracer analysis from the injection and monitoring wells on a regular basis. Results show a fast

  6. Initial direct comparison of 99mTc-TOC and 99mTc-TATE in identifying sites of disease in patients with proven GEP NETs.

    PubMed

    Cwikla, Jaroslaw B; Mikolajczak, Renata; Pawlak, Dariusz; Buscombe, John R; Nasierowska-Guttmejer, Anna; Bator, Andrzej; Maecke, Helmut R; Walecki, Jerzy

    2008-07-01

    The imaging of neuroendocrine tumors has become one of the most significant areas in nuclear oncology. In an attempt to provide high-quality imaging and possible sensitivity at a reduced cost, time, and radiation dose, several (99m)Tc agents have been proposed. The aim of this initial study was to compare the tumor uptake and biodistribution of 2 new 6-hydrazinopyridine-3-carboxylic acid (HYNIC)-derivatized Tyr(3)-octreotide analogs, (99m)Tc-[HYNIC,Tyr(3)]octreotide ((99m)Tc-TOC) and (99m)Tc-[HYNIC,Tyr(3),Thr(8)]octreotide ((99m)Tc-TATE), in patients with somatostatin receptor-expressing tumors. Each of 12 patients with proven gastrointestinal pancreatic neuroendocrine tumors received a mean activity of 520 MBq of (99m)Tc-TOC and (99m)Tc-TATE. Scintigraphy with both tracers was performed 3-4 h after their injection using standard whole-body and SPECT imaging. The images were reviewed subjectively by 2 readers, who reported tumor uptake lesion by lesion. Both radiotracers demonstrated concordance between the results in 7 patients (58%). In total, 110 sites of disease were identified with (99m)Tc-TOC, compared with 115 with (99m)Tc-TATE. There was 1 case in which (99m)Tc-TOC identified sites of disease not seen on (99m)Tc-TATE imaging but 4 cases in which some sites of disease were seen with (99m)Tc-TATE and not (99m)Tc-TOC. In this initial study, both tracers seem to show similar sites of tumor, with (99m)Tc-TATE having a slight edge in the total number of lesions seen, especially in lymph node metastases.

  7. True Airspeed Measurement by Ionization-Tracer Technique

    NASA Technical Reports Server (NTRS)

    Boyd, B.; Dorsch, R. G.; Brodie, G. H.

    1952-01-01

    Ion bundles produced in a pulse-excited corona discharge are used as tracers with a radar-like pulse transit-time measuring instrument in order to provide a measurement of airspeed that is independent of all variables except time and distance. The resulting instrumentation need not project into the air stream and, therefore, will not cause any interference in supersonic flow. The instrument was tested at Mach numbers ranging from 0.3 to 3.8. Use of the proper instrumentation and technique results in accuracy of the order of 1 percent.

  8. Prediction of down-gradient impacts of DNAPL source depletion using tracer techniques: Laboratory and modeling validation

    NASA Astrophysics Data System (ADS)

    Jawitz, J. W.; Basu, N.; Chen, X.

    2007-05-01

    Interwell application of coupled nonreactive and reactive tracers through aquifer contaminant source zones enables quantitative characterization of aquifer heterogeneity and contaminant architecture. Parameters obtained from tracer tests are presented here in a Lagrangian framework that can be used to predict the dissolution of nonaqueous phase liquid (NAPL) contaminants. Nonreactive tracers are commonly used to provide information about travel time distributions in hydrologic systems. Reactive tracers have more recently been introduced as a tool to quantify the amount of NAPL contaminant present within the tracer swept volume. Our group has extended reactive tracer techniques to also characterize NAPL spatial distribution heterogeneity. By conceptualizing the flow field through an aquifer as a collection of streamtubes, the aquifer hydrodynamic heterogeneities may be characterized by a nonreactive tracer travel time distribution, and NAPL spatial distribution heterogeneity may be similarly described using reactive travel time distributions. The combined statistics of these distributions are used to derive a simple analytical solution for contaminant dissolution. This analytical solution, and the tracer techniques used for its parameterization, were validated both numerically and experimentally. Illustrative applications are presented from numerical simulations using the multiphase flow and transport simulator UTCHEM, and laboratory experiments of surfactant-enhanced NAPL remediation in two-dimensional flow chambers.

  9. Normal regional distribution of cerebral blood flow in dogs: comparison between (99m) Tc-ethylcysteinate dimer and (99m) Tc- hexamethylpropylene amine oxime single photon emission computed tomography.

    PubMed

    Adriaens, Antita; Polis, Ingeborgh; Waelbers, Tim; Vandermeulen, Eva; Dobbeleir, André; De Spiegeleer, Bart; Peremans, Kathelijne

    2013-01-01

    Functional imaging provides important insights into canine brain pathologies such as behavioral problems. Two (99m) Tc-labeled single photon emission computed tomography (SPECT) cerebral blood flow tracers-ethylcysteinate dimer (ECD) and hexamethylpropylene amine oxime (HMPAO)-are commonly used in human medicine and have been used previously in dogs but intrasubject comparison of both tracers in dogs is lacking. Therefore, this study investigated whether regional distribution differences between both tracers occur in dogs as is reported in humans. Eight beagles underwent two SPECT examinations first with (99m) Tc-ECD and followed by (99m) Tc-HMPAO. SPECT scanning was performed with a triple head gamma camera equipped with ultrahigh resolution parallel hole collimators. Images were reconstructed using filtered backprojection with a Butterworth filter. Emission data were fitted to a template permitting semiquantification using predefined regions or volumes of interest (VOIs). For each VOI, perfusion indices were calculated by normalizing the regional counts per voxel to total brain counts per voxel. The obtained perfusion indices for each region for both tracers were compared with a paired Student's T-test. Significant (P < 0.05) regional differences were seen in the subcortical region and the cerebellum. Both tracers can be used to visualize regional cerebral blood flow in dogs, however, due to the observed regional differences, they are not entirely interchangeable. © 2013 Veterinary Radiology & Ultrasound.

  10. Assessment of cardiac function using myocardial perfusion imaging technique on SPECT with 99mTc sestamibi

    NASA Astrophysics Data System (ADS)

    Gani, M. R. A.; Nazir, F.; Pawiro, S. A.; Soejoko, D. S.

    2016-03-01

    Suspicion on coronary heart disease can be confirmed by observing the function of left ventricle cardiac muscle with Myocardial Perfusion Imaging techniques. The function perfusion itself is indicated by the uptake of radiopharmaceutical tracer. The 31 patients were studied undergoing the MPI examination on Gatot Soebroto Hospital using 99mTc-sestamibi radiopharmaceutical with stress and rest conditions. Stress was stimulated by physical exercise or pharmacological agent. After two hours, the patient did rest condition on the same day. The difference of uptake percentage between stress and rest conditions will be used to determine the malfunction of perfusion due to ischemic or infarct. Degradation of cardiac function was determined based on the image-based assessment of five segments of left ventricle cardiac. As a result, 8 (25.8%) patients had normal myocardial perfusion and 11 (35.5%) patients suspected for having partial ischemia. Total ischemia occurred to 8 (25.8%) patients with reversible and irreversible ischemia and the remaining 4 (12.9%) patients for partial infarct with characteristic the percentage of perfusion ≤50%. It is concluded that MPI technique of image-based assessment on uptake percentage difference between stress and rest conditions can be employed to predict abnormal perfusion as complementary information to diagnose the cardiac function.

  11. Prediction of Down-Gradient Impacts of DNAPL Source Depletion Using Tracer Techniques

    NASA Astrophysics Data System (ADS)

    Basu, N. B.; Fure, A. D.; Jawitz, J. W.

    2006-12-01

    Four simplified DNAPL source depletion models that have been discussed in the literature recently are evaluated for the prediction of long-term effects of source depletion under natural gradient flow. These models are simple in form (a power function equation is an example) but are shown here to serve as mathematical analogs to complex multiphase flow and transport simulators. One of the source depletion models, the equilibrium streamtube model, is shown to be relatively easily parameterized using non-reactive and reactive tracers. Non-reactive tracers are used to characterize the aquifer heterogeneity while reactive tracers are used to describe the mean DNAPL mass and its distribution. This information is then used in a Lagrangian framework to predict source remediation performance. In a Lagrangian approach the source zone is conceptualized as a collection of non-interacting streamtubes with hydrodynamic and DNAPL heterogeneity represented by the variation of the travel time and DNAPL saturation among the streamtubes. The travel time statistics are estimated from the non-reactive tracer data while the DNAPL distribution statistics are estimated from the reactive tracer data. The combined statistics are used to define an analytical solution for contaminant dissolution under natural gradient flow. The tracer prediction technique compared favorably with results from a multiphase flow and transport simulator UTCHEM in domains with different hydrodynamic heterogeneity (variance of the log conductivity field = 0.2, 1 and 3).

  12. Relationship between intraprostatic tracer deposits and sentinel lymph node mapping in prostate cancer patients.

    PubMed

    Buckle, Tessa; Brouwer, Oscar R; Valdés Olmos, Renato A; van der Poel, Henk G; van Leeuwen, Fijs W B

    2012-07-01

    Intraprostatic injection of the hybrid tracer indocyanine green (ICG)-(99m)Tc-nanocolloid enables both preoperative sentinel node (SN) identification and intraoperative visualization of the SN. Relating the fluorescence deposits in embedded prostate tissue specimens to the preoperatively detected SNs also provides the opportunity to study the influence of their placement on lymphatic drainage pattern. Nineteen patients with prostate carcinoma scheduled for robot-assisted laparoscopic prostatectomy and lymph node (LN) dissection were included. ICG-(99m)Tc-nanocolloid was injected intraprostatically, guided by ultrasound. SN biopsy was performed using a combination of radioguidance and fluorescence guidance. Tracer distribution was visualized in paraffin-embedded prostate samples using ex vivo fluorescence imaging. This distribution was correlated to the number and location of the SNs identified on preoperative lymphoscintigraphy and SPECT/CT. ICG-(99m)Tc-nanocolloid helped guide surgical excision of the SNs. Ex vivo fluorescence imaging revealed a large variation in the locations of intraprostatic tracer deposits among patients. Tracer deposits in the peripheral zone correlated with a higher number of visualized LNs than deposits in the central zone (on average, 4.7 vs. 2.4 LNs per patient). Furthermore, tracer deposits in the mid gland correlated with a higher number of visualized LNs than deposits near the base or apex of the prostate (on average, 6 vs. 3.5 LNs per patient). The hybrid nature of the tracer not only enables surgical guidance but also provides an opportunity to study the correlation between the location of tracer deposits within the prostate and the number and location of preoperatively visualized SNs. These data suggest that the location at which a tracer deposit is placed influences the lymphatic drainage pattern.

  13. Determination of 99Tc in fresh water using TRU resin by ICP-MS.

    PubMed

    Guérin, Nicolas; Riopel, Remi; Kramer-Tremblay, Sheila; de Silva, Nimal; Cornett, Jack; Dai, Xiongxin

    2017-10-02

    Technetium-99 ( 99 Tc) determination at trace level by inductively coupled plasma mass spectrometry (ICP-MS) is challenging because there is no readily available appropriate Tc isotopic tracer. A new method using Re as a recovery tracer to determine 99 Tc in fresh water samples, which does not require any evaporation step, was developed. Tc(VII) and Re(VII) were pre-concentrated on a small anion exchange resin (AER) cartridge from one litre of water sample. They were then efficiently eluted from the AER using a potassium permanganate (KMnO 4 ) solution. After the reduction of KMnO 4 in 2 M sulfuric acid solution, the sample was passed through a small TRU resin cartridge. Tc(VII) and Re(VII) retained on the TRU resin were eluted using near boiling water, which can be directly used for the ICP-MS measurement. The results for method optimisation, validation and application were reported. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  14. Hybrid radioguided occult lesion localization (hybrid ROLL) of (18)F-FDG-avid lesions using the hybrid tracer indocyanine green-(99m)Tc-nanocolloid.

    PubMed

    KleinJan, G H; Brouwer, O R; Mathéron, H M; Rietbergen, D D D; Valdés Olmos, R A; Wouters, M W; van den Berg, N S; van Leeuwen, F W B

    2016-01-01

    To assess if combined fluorescence- and radio-guided occult lesion localization (hybrid ROLL) is feasible in patients scheduled for surgical resection of non-palpable (18)F-FDG-avid lesions on PET/CT. Four patients with (18)F-FDG-avid lesions on follow-up PET/CT that were not palpable during physical examination but were suspected to harbor metastasis were enrolled. Guided by ultrasound, the hybrid tracer indocyanine green (ICG)-(99m)Tc-nanocolloid was injected centrally in the target lesion. SPECT/CT imaging was used to confirm tracer deposition. Intraoperatively, lesions were localized using a hand-held gamma ray detection probe, a portable gamma camera, and a fluorescence camera. After excision, the gamma camera was used to check the wound bed for residual activity. A total of six (18)F-FDG-avid lymph nodes were identified and scheduled for hybrid ROLL. Comparison of the PET/CT images with the acquired SPECT/CT after hybrid tracer injection confirmed accurate tracer deposition. No side effects were observed. Combined radio- and fluorescence-guidance enabled localization and excision of the target lesion in all patients. Five of the six excised lesions proved tumor-positive at histopathology. The hybrid ROLL approach appears to be feasible and can facilitate the intraoperative localization and excision of non-palpable lesions suspected to harbor tumor metastases. In addition to the initial radioguided detection, the fluorescence component of the hybrid tracer enables high-resolution intraoperative visualization of the target lesion. The procedure needs further evaluation in a larger cohort and wider range of malignancies to substantiate these preliminary findings. Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  15. Insights into the failure of the potential, neutral myocardial imaging agent TcN-NOET: physicochemical identification of by-products and degradation species.

    PubMed

    Tisato, Francesco; Bolzati, Cristina; Refosco, Fiorenzo; Porchia, Marina; Seraglia, Roberta; Carta, Davide; Pasqualini, Roberto

    2012-04-01

    The neutral complex [(99m)Tc(N)(NOEt)(2)], often referred to as TcN-NOET [NOEt=N-ethoxy,N-ethyldithiocarbamate(1-)], was proposed several years ago as a myocardial imaging agent. Despite some favorable clinical properties evidenced during phase I and phase II studies, the overall results of the European and American phase III clinical studies have been judged insufficient for a successful approval process by the regulatory agencies. Non-carrier-added and carrier-added experiments using short-lived (99m)Tc and long-lived (99g)Tc have been utilized to prepare a series of bis-substituted [Tc(N)(DTC)(2)] complexes [DTC=dithiocarbamate(1-)]. They have been purified by means of chromatographic techniques (high-performance liquid chromatography and thin-layer chromatography) and identified via double detection (UV-vis and radiometry) by comparison with authenticated samples of (99g)Tc compounds prepared by conventional coordination chemistry procedures. The molecular structure of the lipophilic, neutral complex cis-[Tc(N)(NOEt)(2)] has been assigned by comparison with similar nitrido-Tc(V) complexes already reported in the literature. Novel bis-substituted nitrido-Tc complexes containing hydrolyzed portions of coordinated NOEt, namely, N-ethyldithiocarbamate [NHEt(1-)] and N-hydroxy, N-ethyldithiocarbamate [NOHEt(1-)], have been prepared and characterized by means of multinuclear nuclear magnetic resonance spectroscopy and mass spectrometry. Despite the identification of these "hydrolyzed" species, it is still unclear whether the failure to reach the clinical goal of the perfusion tracer [(99m)Tc(N)(NOEt)(2)] is related to the degradation processes evidenced in this study or is the result of the mediocre imaging properties of the tracer. Copyright © 2012 Elsevier Inc. All rights reserved.

  16. Use of Tc-99m-galactosyl-neoglycoalbumin (Tc-NGA) to determine hepatic blood flow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stadalnik, R.C.; Vera, D.R.; Woodle, E.S.

    1984-01-01

    Tc-NGA is a new liver radiopharmaceutical which binds to a hepatocyte-specific membrane receptor. Three characteristics of Tc-NGA can be exploited in the measurement of hepatic blood flow (HBF): 1) ability to alter the affinity of Tc-NGA for its receptor by changing the galactose: albumin ratio; 2) ability to achieve a high specific activity with Tc-99m labeling; and 3) ability to administer a high molar dose of Tc-NGA without physiologic side effects. In addition, kinetic modeling of Tc-NGA dynamic data can provide estimates of hepatic receptor concentration. In experimental studies in young pigs, HBF was determined using two techniques: 1) kineticmore » modeling of dynamic data using moderate affinity, low specific activity Tc-NGA (Group A, n=12); and 2) clearance (CL) technique using high affinity, high specific activity Tc-NGA (Group B, n=4). In both groups, HBF was determined simultaneously by continuous infusion of indocyanine green (CI-ICG) with hepatic vein sampling. Regression analysis of HBF measurements obtained with the Tc-NGA kinetic modeling technique and the CI-ICG technique (Group A) revealed good correlation between the two techniques (r=0.802, p=0.02). Similarly, HBF determination by the clearance technique (Group B) provided highly accurate measurements when compared to the CI-ICG technique. Hepatic blood flow measurements by the clearance technique (CL-NGA) fell within one standard deviation of the error associated with each CI-ICG HBF measurement (all CI-ICG standard deviations were less than 10%).« less

  17. The separation of 99Tc from low and medium-level radioactive wastes and its determination by inductively coupled plasma mass spectrometry.

    PubMed

    Hepiegne, P; Dall'ava, D; Clement, R; Degros, J P

    1995-06-01

    A chemical separation method has been developed for the determination of (99)Tc in various types of radioactive wastes. Such a method includes (i) fusion with NaOH, (ii) extraction in a column containing methyltrioctylammonium chloride, (iii) extraction by solvent with N-benzoyl-N-phenylhydroxylamine and, (iv) measurement by inductively-coupled plasma mass spectrometry (ICP-MS). From the performance standpoint, the recovery of (99)Tc, using (99m)Tc as a yield tracer, is higher than 70%. This analytical method, as developed, ensures effective decontamination with respect to the radionuclides, insofar the decontamination factors are greater than 10(+5), whenever the residual activity may be measured. Taking into account a 3sigma counting error, the detection limit obtained with the ICP-MS technique is 1.9 mBq/ml; the method enabling hence to detect activities as low as 0.3 Bq/g, with analysed samples of 0.2 g and a radiochemical yield of 70%. Studies have been dedicated to the (99)Tc measurement, using the electrothermal vaporization ICP-MS technique, which lowers the detection limit by a factor 10, with the standard solution (0.3 pg/ml), compared with the previous ICP-MS technique.

  18. Radiosynthesis and Biodistribution of 99mTc-Metronidazole as an Escherichia coli Infection Imaging Radiopharmaceutical.

    PubMed

    Iqbal, Anam; Naqvi, Syed Ali Raza; Rasheed, Rashid; Mansha, Asim; Ahmad, Matloob; Zahoor, Ameer Fawad

    2018-05-01

    Bacterial infection poses life-threatening challenge to humanity and stimulates to the researchers for developing better diagnostic and therapeutic agents complying with existing theranostic techniques. Nuclear medicine technique helps to visualize hard-to-diagnose deep-seated bacterial infections using radionuclide-labeled tracer agents. Metronidazole is an antiprotozoal antibiotic that serves as a preeminent anaerobic chemotherapeutic agent. The aim of this study was to develop technetium-99m-labeled metronidazole radiotracer for the detection of deep-seated bacterial infections. Radiosynthesis of 99m Tc-metronidazole was carried by reacting reduced technetium-99m and metronidazole at neutral pH for 30 min. The stannous chloride dihydrate was used as the reducing agent. At optimum radiolabeling conditions, ~ 94% radiochemical was obtained. Quality control analysis was carried out with a chromatographic paper and instant thin-layer chromatographic analysis. The biodistribution study of radiochemical was performed using Escherichia coli bacterial infection-induced rat model. The scintigraphic study was performed using E. coli bacterial infection-induced rabbit model. The results showed promising accumulation at the site of infection and its rapid clearance from the body. The tracer showed target-to-non-target ratio 5.57 ± 0.04 at 1 h post-injection. The results showed that 99m Tc-MNZ has promising potential to accumulate at E. coli bacterial infection that can be used for E. coli infection imaging.

  19. Application of fluorescently labeled tracer technique for detection of natural active macromolecules in Chinese medicine.

    PubMed

    Zeng, Qiao-Hui; Zhang, Xue-Wu; Xu, Kai-Peng; Jiang, Jian-Guo

    2014-02-01

    Active substances in traditional Chinese Medicine (TCM) contain not only a variety of small molecules, but also many other macromolecules (TCMMs), such as proteins, peptides and polysaccharides. Active TCMM can achieve good therapeutic effects by regulating the body's overall function with lower side effects. This review summarized the literatures published in recent years on the application of fluorescently labeled tracer technique for detection of natural active macromolecules in TCM. Classified by fluorescent markers, applications of fluorescein, rhodamine, and quantum dots (QDs) in TCMM active tracer are reviewed, and the methods and principles of TCMM fluorescent marker are illustrated. Studies on active TCMMs and their action mechanism are quite difficult due to a multitarget, multicomponent, and multipath system of TCM. However, the development of fluorescently labeled active tracer technique (FLATT) provides this research with new tools. Traditional fluorescent markers have many deficiencies, such as easily quenched, short luminous cycle, and intrinsic toxicity. Relatively, FLATT has many obvious advantages, and its application in TCMM is still at the early stage. In order to improve the overall level of fluorescence labeling in TCMM active tracer, the improvement on FLATT's detection sensitivity and biological affinity is urgent and critical to allow study of these interesting molecules.

  20. A tracer dose of technetium-99m-labeled liposomes can estimate the effect of hyperthermia on intratumoral doxil extravasation.

    PubMed

    Kleiter, Miriam M; Yu, Daohai; Mohammadian, Lenore A; Niehaus, Nelsen; Spasojevic, Ivan; Sanders, Linda; Viglianti, Benjamin L; Yarmolenko, Pavel S; Hauck, Marlene; Petry, Neil A; Wong, Terence Z; Dewhirst, Mark W; Thrall, Donald E

    2006-11-15

    A noninvasive method to monitor intratumoral Doxil delivery in individual patients during targeted tumor therapy is important to predict treatment response. The purpose of this study was to determine if a small tracer dose of technetium-99m (99mTc)-labeled liposomes could be used to quantify the effect of local hyperthermia on intratumoral Doxil extravasation. Experiments were carried out in a rat fibrosarcoma model with transplanted thigh tumors. Liposomes of approximately same size and composition as Doxil were radiolabeled using [technetium-99m (99mTc)]exametazime. Eight treatment groups received either Doxil, a tracer dose or a large dose of 99mTc-labeled liposomes, or a combination of tracer and Doxil, with or without hyperthermia. This design was chosen to assure that coadministration of both liposomal formulations did not influence their intratumoral distribution. Hyperthermia was done for 45 minutes. Scintigraphic images were obtained at 5 and 18 hours. At 18 hours, tumors were removed and gamma counts as well as doxorubicin concentrations were measured. Intratumoral extravasation of the 99mTc-labeled tracer could be imaged scintigraphically under normothermic and hyperthermic conditions. The thermal enhancement ratio was slightly higher for radiolabeled liposomes than for doxorubicin concentration. However, there was a significant positive correlation of intratumoral doxorubicin concentration and intratumoral uptake of the radiolabeled tracer (expressed as percentage of the injected dose per gram of tissue). Coadministration of radiolabeled liposomes did not negatively influence the amount of drug delivered with Doxil. The use of a radiolabeled tracer has potential value to monitor drug delivery and estimate the effect of an intervention aimed to increase liposomal accumulation, such as local hyperthermia.

  1. Sorption of99mTc radiopharmaceutical compounds by soils

    USGS Publications Warehouse

    Jurisson, S.; Gawenis, J.; Landa, E.R.

    2004-01-01

    Study of the sorption of 99mTc radiopharmaceutical compounds by soils has assessed the fate of these compounds in the event of a surface spill and examined the potential of these compounds as hydrologic tracers. Sorption from deionized water, filtered Missouri River water, and artificial seawater by five surface soils was investigated. For all water types, the Tc radiopharmaceutical compounds showed greater sorption than the uncomplexed pertechnetate. The most lipophilic complexes showed the highest sorption on soils.

  2. Tracer-Test Planning Using the Efficient Hydrologic Tracer ...

    EPA Pesticide Factsheets

    Hydrological tracer testing is the most reliable diagnostic technique available for establishing flow trajectories and hydrologic connections and for determining basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test design can be difficult because of a lack of prior knowledge of the basic hydraulic and geometric parameters desired and the appropriate tracer mass to release. A new efficient hydrologic tracer-test design (EHTD) methodology has been developed that combines basic measured field parameters (e.g., discharge, distance, cross-sectional area) in functional relationships that describe solute-transport processes related to flow velocity and time of travel. The new method applies these initial estimates for time of travel and velocity to a hypothetical continuously stirred tank reactor as an analog for the hydrologic flow system to develop initial estimates for tracer concentration and axial dispersion, based on a preset average tracer concentration. Root determination of the one-dimensional advection-dispersion equation (ADE) using the preset average tracer concentration then provides a theoretical basis for an estimate of necessary tracer mass.Application of the predicted tracer mass with the hydraulic and geometric parameters in the ADE allows for an approximation of initial sample-collection time and subsequent sample-collection frequency where a maximum of 65 samples were determined to be

  3. Waste Oil Burn-Off in Coast Guard Power Plants - Diesel Piston Ring Wear Study by Radioactive Tracer Techniques

    DOT National Transportation Integrated Search

    1976-07-01

    This report covers the results of a study utilizing a radioactive tracer technique to determine wear effects on the upper compression rings of a two-stroke cycle diesel engine burning mixtures of waste lube oil in fuel oil. The radioactive tracer tec...

  4. Journal: Efficient Hydrologic Tracer-Test Design for Tracer ...

    EPA Pesticide Factsheets

    Hydrological tracer testing is the most reliable diagnostic technique available for the determination of basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test design can be difficult because of a lack of prior knowledge of the basic hydraulic and geometric parameters desired and the appropriate tracer mass to release. A new efficient hydrologic tracer-test design (EHTD) methodology has been developed to facilitate the design of tracer tests by root determination of the one-dimensional advection-dispersion equation (ADE) using a preset average tracer concentration which provides a theoretical basis for an estimate of necessary tracer mass. The method uses basic measured field parameters (e.g., discharge, distance, cross-sectional area) that are combined in functional relatipnships that descrive solute-transport processes related to flow velocity and time of travel. These initial estimates for time of travel and velocity are then applied to a hypothetical continuous stirred tank reactor (CSTR) as an analog for the hydrological-flow system to develop initial estimates for tracer concentration, tracer mass, and axial dispersion. Application of the predicted tracer mass with the hydraulic and geometric parameters in the ADE allows for an approximation of initial sample-collection time and subsequent sample-collection frequency where a maximum of 65 samples were determined to be necessary for descri

  5. Skeletal scintigraphy and quantitative tracer studies in metabolic bone disease

    NASA Astrophysics Data System (ADS)

    Fogelman, Ignac

    Bone scan imaging with the current bone seeking radiopharmaceuticals, the technetium-99m labelled diphosphonates, has dramatically improved our ability to evaluate skeletal pathology. In this thesis, chapter 1 presents a review of the history of bone scanning, summarises present concepts as to the mechanism of uptake of bone seeking agents and briefly illustrates the role of bone scanning in clinical practice. In chapter 2 the applications of bone scan imaging and quantitative tracer techniques derived from the bone scan in the detection of metabolic bone disease are discussed. Since skeletal uptake of Tc-99m diphosphonate depends upon skeletal metabolism one might expect that the bone scan would be of considerable value in the assessment of metabolic bone disease. However in these disorders the whole skeleton is often diffusely involved by the metabolic process and simple visual inspection of the scan image may not reveal the uniformly increased uptake of tracer. Certain patterns of bone scan abnormality have, however, been reported in patients with primary hyperparathyroidism and renal osteo-dystrophy; the present studies extend these observations and introduce the concept of "metabolic features" which are often recognisable in conditions with generalised increased bone turnover. As an aid to systematic recognition of these features on a given bone scan image a semi-quantitative scoring system, the metabolic index, was introduced. The metabolic index allowed differentiation between various groups of patients with metabolic disorders and a control population. In addition, in a bone scan study of patients with acromegaly, it was found that the metabolic index correlated well with disease activity as measured by serum growth hormone levels. The metabolic index was, however, found to be a relatively insensitive means of identifying disease in individual patients. Patients with increased bone turnover will have an absolute increase in skeletal uptake of tracer. As a

  6. Development and Pharmacological Evaluation of New Bone-Targeted (99m)Tc-Radiolabeled Bisphosphonates.

    PubMed

    Makris, George; Tseligka, Eirini D; Pirmettis, Ioannis; Papadopoulos, Minas S; Vizirianakis, Ioannis S; Papagiannopoulou, Dionysia

    2016-07-05

    A novel bisphosphonate, 1-(3-aminopropylamino)ethane-1,1-diyldiphosphonic acid (3), was coupled to the tridentate chelators di-2-picolylamine, 2-picolylamine-N-acetic acid, iminodiacetic acid, 3-((2-aminoethyl)thio)-3-(1H-imidazol-4-yl)propanoic acid, and 2-((2-carboxyethyl)thio)-3-(1H-imidazol-4-yl)propanoic acid to form ligands 6, 9, 11, 15, and 19, respectively. Organometallic complexes of the general formula [Re/(99m)Tc(CO)3(κ(3)-L)] were synthesized, where L denotes ligand 6, 9, 11, 15, or 19. The rhenium complexes were prepared at the macroscopic level and characterized by spectroscopic methods. The technetium-99m organometallic complexes were synthesized in high yield and were identified by comparative reversed-phase HPLC with their Re analogues. The (99m)Tc tracers were stable in vitro and exhibited binding to hydroxyapatite. In biodistribution studies, all of the (99m)Tc complexes exhibited high bone uptake superior to that of 25, which is the directly (99m)Tc-labeled bisphosphonate 3, and comparable to that of (99m)Tc-methylene diphosphonate ((99m)Tc-MDP). The tracers [(99m)Tc(CO)3(6)] (26), [(99m)Tc(CO)3(9)] (27), [(99m)Tc(CO)3(11)] (28), and [(99m)Tc(CO)3(15)] (29) exhibited higher bone/blood ratios than (99m)Tc-MDP. 26 had the highest bone uptake at 1 h p.i. The new bisphosphonates showed no substantial growth inhibitory capacity in PC-3, Saos-2, and MCF-7 established cancer cell lines at low concentrations. Incubation of 26 with the same cancer cell lines indicated a rapid and saturated uptake. The promising properties of 26-29 indicate their potential for use as bone-imaging agents.

  7. Linear regression techniques for use in the EC tracer method of secondary organic aerosol estimation

    NASA Astrophysics Data System (ADS)

    Saylor, Rick D.; Edgerton, Eric S.; Hartsell, Benjamin E.

    A variety of linear regression techniques and simple slope estimators are evaluated for use in the elemental carbon (EC) tracer method of secondary organic carbon (OC) estimation. Linear regression techniques based on ordinary least squares are not suitable for situations where measurement uncertainties exist in both regressed variables. In the past, regression based on the method of Deming [1943. Statistical Adjustment of Data. Wiley, London] has been the preferred choice for EC tracer method parameter estimation. In agreement with Chu [2005. Stable estimate of primary OC/EC ratios in the EC tracer method. Atmospheric Environment 39, 1383-1392], we find that in the limited case where primary non-combustion OC (OC non-comb) is assumed to be zero, the ratio of averages (ROA) approach provides a stable and reliable estimate of the primary OC-EC ratio, (OC/EC) pri. In contrast with Chu [2005. Stable estimate of primary OC/EC ratios in the EC tracer method. Atmospheric Environment 39, 1383-1392], however, we find that the optimal use of Deming regression (and the more general York et al. [2004. Unified equations for the slope, intercept, and standard errors of the best straight line. American Journal of Physics 72, 367-375] regression) provides excellent results as well. For the more typical case where OC non-comb is allowed to obtain a non-zero value, we find that regression based on the method of York is the preferred choice for EC tracer method parameter estimation. In the York regression technique, detailed information on uncertainties in the measurement of OC and EC is used to improve the linear best fit to the given data. If only limited information is available on the relative uncertainties of OC and EC, then Deming regression should be used. On the other hand, use of ROA in the estimation of secondary OC, and thus the assumption of a zero OC non-comb value, generally leads to an overestimation of the contribution of secondary OC to total measured OC.

  8. Need and prospects for using tracer techniques in fruit breeding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zagaja, S.W.

    1975-01-01

    Compared with staple food crops and fodder crops, the commercial value of fruits depends more on their quality than on their productivity. Modified screening techniques are therefore required for fruit crop improvement. The following are areas of fruit crop improvement in which tracer techniques could be used to speed up the progress: assessment of rootstocks and particularly their effect on vigour of growth and productivity of the trees; assessment of mutants productivity; assessment of adaptability to various habitats of fruit tree cultivars and rootstocks; and juvenility studies on fruit trees, aimed at shortening the juvenile stage. On each of thesemore » subjects background information is provided and suggestions are made concerning the scope of research. (auth)« less

  9. Tracer-Test Planning Using the Efficient Hydrologic Tracer-Test Design (Ehtd) Program (2005)

    EPA Science Inventory

    Hydrological tracer testing is the most reliable diagnostic technique available for establishing flow trajectories and hydrologic connections and for determining basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test ...

  10. Tracer-Test Planning Using the Efficient Hydrologic Tracer-Test Design (Ehtd) Program (2003)

    EPA Science Inventory

    Hydrological tracer testing is the most reliable diagnostic technique available for establishing flow trajectories and hydrologic connections and for determining basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test ...

  11. Dual tracer imaging of SPECT and PET probes in living mice using a sequential protocol

    PubMed Central

    Chapman, Sarah E; Diener, Justin M; Sasser, Todd A; Correcher, Carlos; González, Antonio J; Avermaete, Tony Van; Leevy, W Matthew

    2012-01-01

    Over the past 20 years, multimodal imaging strategies have motivated the fusion of Positron Emission Tomography (PET) or Single Photon Emission Computed Tomography (SPECT) scans with an X-ray computed tomography (CT) image to provide anatomical information, as well as a framework with which molecular and functional images may be co-registered. Recently, pre-clinical nuclear imaging technology has evolved to capture multiple SPECT or multiple PET tracers to further enhance the information content gathered within an imaging experiment. However, the use of SPECT and PET probes together, in the same animal, has remained a challenge. Here we describe a straightforward method using an integrated trimodal imaging system and a sequential dosing/acquisition protocol to achieve dual tracer imaging with 99mTc and 18F isotopes, along with anatomical CT, on an individual specimen. Dosing and imaging is completed so that minimal animal manipulations are required, full trimodal fusion is conserved, and tracer crosstalk including down-scatter of the PET tracer in SPECT mode is avoided. This technique will enhance the ability of preclinical researchers to detect multiple disease targets and perform functional, molecular, and anatomical imaging on individual specimens to increase the information content gathered within longitudinal in vivo studies. PMID:23145357

  12. Simultaneous acquisition of (99m)Tc- and (123)I-labeled radiotracers using a preclinical SPECT scanner with CZT detectors.

    PubMed

    Kobayashi, Masato; Matsunari, Ichiro; Nishi, Kodai; Mizutani, Asuka; Miyazaki, Yoshiharu; Ogai, Kazuhiro; Sugama, Jyunko; Shiba, Kazuhiro; Kawai, Keiichi; Kinuya, Seigo

    2016-05-01

    Simultaneous acquisition of (99m)Tc and (123)I was evaluated using a preclinical SPECT scanner with cadmium zinc telluride (CZT)-based detectors. 10-ml cylindrical syringes contained about 37 MBq (99m)Tc-tetrofosmin ((99m)Tc-TF) or 37 MBq (123)I-15-(p-iodophenyl)-3R,S-methyl pentadecanoic acid ((123)I-BMIPP) were used to assess the relationship between these SPECT radioactive counts and radioactivity. Two 10-ml syringes contained 100 or 300 MBq (99m)Tc-TF and 100 MBq (123)I-BMIPP to assess the influence of (99m)Tc upscatter and (123)I downscatter, respectively. A rat-sized cylindrical phantom also contained both 100 or 300 MBq (99m)Tc-TF and 100 MBq (123)I-BMIPP. The two 10-ml syringes and phantom were scanned using a pinhole collimator for rats. Myocardial infarction model rats were examined using 300 MBq (99m)Tc-TF and 100 MBq (123)I-BMIPP. Two 1-ml syringes contained 105 MBq (99m)Tc-labeled hexamethylpropyleneamine oxime ((99m)Tc-HMPAO) and 35 MBq (123)I-labeled N-ω-fluoropropyl-2β-carbomethoxy-3β-(4-iodophenyl) nortropane ((123)I-FP-CIT). The two 1-ml syringes were scanned using a pinhole collimator for mice. Normal mice were examined using 105 MBq (99m)Tc-HMPAO and 35 MBq (123)I-FP-CIT. The relationship between SPECT radioactive counts and radioactivity was excellent. Downscatter contamination of (123)I-BMIPP exhibited fewer radioactive counts for 300 MBq (99m)Tc-TF without scatter correction (SC) in 125-150 keV. There was no upscatter contamination of (99m)Tc-TF in 150-175 keV. In the rat-sized phantom, the radioactive count ratio decreased to 4.0 % for 300 MBq (99m)Tc-TF without SC in 125-150 keV. In the rats, myocardial images and radioactive counts of (99m)Tc-TF with the dual tracer were identical to those of the (99m)Tc-TF single injection. Downscatter contamination of (123)I-FP-CIT was 4.2 % without SC in 125-150 keV. In the first injection of (99m)Tc-HMPAO and second injection of (123)I-FP-CIT, brain images and radioactive counts

  13. Estimating the gas and dye quantities for modified tracer technique measurements of stream reaeration coefficients

    USGS Publications Warehouse

    Rathbun, R.E.

    1979-01-01

    Measuring the reaeration coefficient of a stream with a modified tracer technique has been accomplished by injecting either ethylene or ethylene and propane together and a rhodamine-WT dye solution into the stream. The movement of the tracers through the stream reach after injection is described by a one-dimensional diffusion equation. The peak concentrations of the tracers at the downstream end of the reach depend on the concentrations of the tracers in the stream at the injection site, the longitudinal dispersion coefficient, the mean water velocity, the length of the reach, and the duration of the injection period. The downstream gas concentrations also depend on the gas desorption coefficients of the reach. The concentrations of the tracer gases in the stream at the injection site depend on the flow rates of the gases through the injection diffusers, the efficiency of the gas absorption process, and the stream discharge. The concentration of dye in the stream at the injection site depends on the flow rate of the dye solution, the concentration of the dye solution, and the stream discharge. Equations for estimating the gas flow rates, the quantities of the gases, the dye concentration, and the quantity of dye together with procedures for determining the variables in these equations are presented. (Woodard-USGS)

  14. A Dye-Tracer Technique for Experimentally Obtaining Impingement Characteristics of Arbitrary Bodies and a Method for Determining Droplet Size Distribution

    NASA Technical Reports Server (NTRS)

    VonGlahn, Uwe H.; Gelder, Thomas F.; Smyers, William H., Jr.

    1955-01-01

    A dye-tracer technique has been developed whereby the quantity of dyed water collected on a blotter-wrapped body exposed to an air stream containing a dyed-water spray cloud can be colorimetrically determined in order to obtain local collection efficiencies, total collection efficiency, and rearward extent of impingement on the body. In addition, a method has been developed whereby the impingement characteristics obtained experimentally for a body can be related to theoretical impingement data for the same body in order to determine the droplet size distribution of the impinging cloud. Several cylinders, a ribbon, and an aspirating device to measure cloud liquid-water content were used in the studies presented herein for the purpose of evaluating the dye-tracer technique. Although the experimental techniques used in the dye-tracer technique require careful control, the methods presented herein should be applicable for any wind tunnel provided the humidity of the air stream can be maintained near saturation.

  15. SPECT/CT tracer uptake is influenced by tunnel orientation and position of the femoral and tibial ACL graft insertion site.

    PubMed

    Hirschmann, Michael T; Mathis, Dominic; Rasch, Helmut; Amsler, Felix; Friederich, Niklaus F; Arnold, Markus P

    2013-02-01

    SPECT/CT is a hybrid imaging modality, which combines a 3D scintigraphy (SPECT) and a conventional computerised tomography (CT). SPECT/CT allows accurate anatomical localisation of metabolic tracer activity. It allows the correlation of surgical factors such as tunnel position and orientation with mechanical alignment, clinical outcome and biological factors. The purpose of this study was to investigate whether the SPECT/CT tracer uptake (intensity and distribution) correlates with the stability and laxity of the knee joint and the position and orientation of the tibial and femoral tunnels in patients after anterior cruciate ligament (ACL) reconstruction. A consecutive series of knees (n=66), with symptoms of pain and/or instability after ACL reconstruction were prospectively evaluated using clinical examination and 99mTc-HDP-SPECT/CT. Clinical laxity testing was performed using the Rolimeter (Ormed, Freiburg, Germany) including Lachman testing (0-2 mm, 3-5 mm, 6-10 mm, >10 mm), anterior drawer test (0-2 mm, 3-5 mm, 6-10 mm, >10 mm), pivot shift test (positive versus negative) and patient-based subjective instability (yes versus no). For analysis of SPECT/CT tracer uptake a previously validated SPECT/CT localisation scheme consisting of 17 tibial, nine femoral and four patellar regions on standardised axial, coronal, and sagittal slices was used. The tracer activity on SPECT/CT was localised and recorded using a 3D volumetric and quantitative analysis software. Mean, standard deviation, minimum and maximum of grading for each area of the localisation scheme were recorded. The position and orientation of the tibial and femoral tunnel was assessed using a previously published method on 3D-CT. Correlation of instability, pivot shift as well as clinical laxity testing with 99mTc-HDP-SPECT/CT tracer uptake intensity and distribution showed no significant correlation. 99mTc-HDP-SPECT/CT tracer uptake correlated significantly with the position and orientation of the ACL

  16. Fluorescence guided surgery and tracer-dose, fact or fiction?

    PubMed

    KleinJan, Gijs H; Bunschoten, Anton; van den Berg, Nynke S; Olmos, Renato A Valdès; Klop, W Martin C; Horenblas, Simon; van der Poel, Henk G; Wester, Hans-Jürgen; van Leeuwen, Fijs W B

    2016-09-01

    Fluorescence guidance is an upcoming methodology to improve surgical accuracy. Challenging herein is the identification of the minimum dose at which the tracer can be detected with a clinical-grade fluorescence camera. Using a hybrid tracer such as indocyanine green (ICG)-(99m)Tc-nanocolloid, it has become possible to determine the accumulation of tracer and correlate this to intraoperative fluorescence-based identification rates. In the current study, we determined the lower detection limit of tracer at which intraoperative fluorescence guidance was still feasible. Size exclusion chromatography (SEC) provided a laboratory set-up to analyze the chemical content and to simulate the migratory behavior of ICG-nanocolloid in tissue. Tracer accumulation and intraoperative fluorescence detection findings were derived from a retrospective analysis of 20 head-and-neck melanoma patients, 40 penile and 20 prostate cancer patients scheduled for sentinel node (SN) biopsy using ICG-(99m)Tc-nanocolloid. In these patients, following tracer injection, single photon emission computed tomography fused with computed tomography (SPECT/CT) was used to identify the SN(s). The percentage injected dose (% ID), the amount of ICG (in nmol), and the concentration of ICG in the SNs (in μM) was assessed for SNs detected on SPECT/CT and correlated with the intraoperative fluorescence imaging findings. SEC determined that in the hybrid tracer formulation, 41 % (standard deviation: 12 %) of ICG was present in nanocolloid-bound form. In the SNs detected using fluorescence guidance a median of 0.88 % ID was present, compared to a median of 0.25 % ID in the non-fluorescent SNs (p-value < 0.001). The % ID values could be correlated to the amount ICG in a SN (range: 0.003-10.8 nmol) and the concentration of ICG in a SN (range: 0.006-64.6 μM). The ability to provide intraoperative fluorescence guidance is dependent on the amount and concentration of the fluorescent dye accumulated in the

  17. Determination of reaeration-rate coefficients of the Wabash River, Indiana, by the modified tracer technique

    USGS Publications Warehouse

    Crawford, Charles G.

    1985-01-01

    The modified tracer technique was used to determine reaeration-rate coefficients in the Wabash River in reaches near Lafayette and Terre Haute, Indiana, at streamflows ranging from 2,310 to 7,400 cu ft/sec. Chemically pure (CP grade) ethylene was used as the tracer gas, and rhodamine-WT dye was used as the dispersion-dilution tracer. Reaeration coefficients determined for a 13.5-mi reach near Terre Haute, Indiana, at streamflows of 3,360 and 7,400 cu ft/sec (71% and 43% flow duration) were 1.4/day and 1.1/day at 20 C, respectively. Reaeration-rate coefficients determined for a 18.4-mile reach near Lafayette, Indiana, at streamflows of 2,310 and 3,420 cu ft/sec (70% and 53 % flow duration), were 1.2/day and 0.8/day at 20 C, respectively. None of the commonly used equations found in the literature predicted reaeration-rate coefficients similar to those measured for reaches of the Wabash River near Lafayette and Terre Haute. The average absolute prediction error for 10 commonly used reaeration equations ranged from 22% to 154%. Prediction error was much smaller in the reach near Terre Haute than in the reach near Lafayette. The overall average of the absolute prediction error for all 10 equations was 22% for the reach near Terre Haute and 128% for the reach near Lafayette. Confidence limits of results obtained from the modified tracer technique were smaller than those obtained from the equations in the literature. 

  18. Quantitative studies of bone using (18)F-fluoride and (99m)Tc-methylene diphosphonate: evaluation of renal and whole-blood kinetics.

    PubMed

    Park-Holohan, S J; Blake, G M; Fogelman, I

    2001-09-01

    We report a study of the renal and whole-blood kinetics of (18)F-fluoride and (99m)Tc-methylene diphosphonate ((99m)Tc-MDP) and their effect on the evaluation of the skeletal kinetics of the two bone tracers. Data were obtained during an investigation of postmenopausal women taking hormone replacement therapy who were compared with untreated, age-matched controls. After intravenous injection of 18F-fluoride (1 MBq), (99m)Tc-MDP (1 MBq), (51)Cr-ethylenediaminetetraacetic acid (51Cr-EDTA) (3 MBq) and (125)I-human serum albumin ((125)I-HSA) (0.25 MBq), multiple blood samples and urine collections were taken between 0 and 4 h after injection. (51)Cr-EDTA data were used to evaluate the glomerular filtration rate (GFR) and the completeness of each timed urine collection. (125)I-HSA data were used to evaluate the plasma volume and the red cell uptake of the other three tracers. At 4 h, the cumulative urine excretions (and standard deviations, SDs) were: (99m)Tc-MDP, 58.2% (4.8%); (18)F-fluoride, 36.1% (5.7%); (51)Cr-EDTA, 81.5% (4.5%). Plots of the renal clearance of (18)F-fluoride against urine volume showed that urine flow rates greater than 5 ml.min-1 were necessary to ensure a constant renal clearance of (18)F and hence stable conditions for the evaluation of bone tracer kinetics. In contrast, a low urine flow rate had no effect on the renal kinetics of (99m)Tc-MDP. For MDP, the evaluation of skeletal kinetics requires data on protein binding so that calculations can be performed for free MDP. In the present study, protein binding of MDP was evaluated from the ratio of total (99m)Tc-MDP renal clearance to GFR based on the principle that free (99m)Tc-MDP is a GFR tracer. Between 0 and 4 h after injection, the fractional protein binding of MDP increased linearly with time, changing from 21+/-5% immediately after injection to 58+/-5% at 4 h. Although red cell uptake of (99m)Tc-MDP was negligible, for (18)F-fluoride around 30% of circulating tracer was transported in red

  19. Clinical Trial with Sodium 99mTc-Pertechnetate Produced by a Medium-Energy Cyclotron: Biodistribution and Safety Assessment in Patients with Abnormal Thyroid Function.

    PubMed

    Selivanova, Svetlana V; Lavallée, Éric; Senta, Helena; Caouette, Lyne; McEwan, Alexander J B; Guérin, Brigitte; Lecomte, Roger; Turcotte, Éric

    2017-05-01

    A single-site prospective open-label clinical study with cyclotron-produced sodium 99m Tc-pertechnetate ( 99m Tc-NaTcO 4 ) was performed in patients with indications for a thyroid scan to demonstrate the clinical safety and diagnostic efficacy of the drug and to confirm its equivalence with conventional 99m Tc-NaTcO 4 eluted from a generator. Methods: 99m Tc-NaTcO 4 was produced from enriched 100 Mo (99.815%) with a cyclotron (24 MeV; 2 h of irradiation) or supplied by a commercial manufacturer (bulk vial eluted from a generator). Eleven patients received 325 ± 29 (mean ± SD) MBq of the cyclotron-produced 99m Tc-NaTcO 4 , whereas the age- and sex-matched controls received a comparable amount of the generator-derived tracer. Whole-body and thyroid planar images were obtained for each participant. In addition to the standard-energy window (140.5 keV ± 7.5%), data were acquired in lower-energy (117 keV ± 10%) and higher-energy (170 keV ± 10%) windows. Vital signs and hematologic and biochemical parameters were monitored before and after tracer administration. Results: Cyclotron-produced 99m Tc-NaTcO 4 showed organ and whole-body distributions identical to those of conventional 99m Tc-NaTcO 4 and was well tolerated. All images led to a clear final diagnosis. The fact that the number of counts in the higher-energy window was significantly higher for cyclotron-produced 99m Tc-NaTcO 4 did not influence image quality in the standard-energy window. Image definition in the standard-energy window with cyclotron-produced 99m Tc was equivalent to that with generator-eluted 99m Tc and had no particular features allowing discrimination between the 99m Tc production methods. Conclusion: The systemic distribution, clinical safety, and imaging efficacy of cyclotron-produced 99m Tc-NaTcO 4 in humans provide supporting evidence for the use of this tracer as an equivalent for generator-eluted 99m Tc-NaTcO 4 in routine clinical practice. © 2017 by the Society of Nuclear Medicine

  20. Limitations and pitfalls of 99mTc-EDDA/HYNIC-TOC (Tektrotyd) scintigraphy.

    PubMed

    Garai, Ildikó; Barna, Sandor; Nagy, Gabor; Forgacs, Attila

    2016-01-01

    Tektrotyd kit was developed by Polatom company for 99mTc labeling to make an alternative tracer of somatostatin receptor scintigraphy available. Since 2005, 99mTc-EDDA/HYNIC-Tyr3-Octreotide has been used in clinical imaging and achieved high impact in management of patients with neuroendocrine tumors. Knowing the limitations and pitfalls is essential to provide ac-curate diagnosis. Therefore, the potential pitfalls associated with the use of 99mTc-EDDA/HYNIC-TOC are reviewed on the basis of own experience. Data were analyzed of 310 patients who underwent somatostatin receptor scintigraphy with 99mTc-Tektrotyd. Pitfalls during radiolabeling process or acquisition can worsen the sensitivity of SRS (somatostatin receptor scintigraphy). Recognizing physi-ological and clinical pitfalls, the diagnostic accuracy will improve.

  1. Tc-NGA imaging in liver transplantation: preliminary clinical experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woodle, E.S.; Ward, R.E.; Stadalnik, R.C.

    1989-03-01

    Technetium-99m galactosyl-neoglycoalbumin (Tc-NGA) is a new liver imaging agent that binds to hepatic-binding protein, a hepatocyte-specific membrane receptor. The purpose of this study was to determine the potential of Tc-NGA imaging in clinical liver transplantation. A total of 25 studies were performed in nine patients. Imaging studies performed in the early posttransplant period in patients with good hepatic allograft function revealed diffuse patchiness in tracer distribution, a manifestation of preservation damage. Left lobar infarction was demonstrated within a few hours of ischemic injury. Right posterior segmental infarction was seen in another patient. Comparison of kinetic, clinical, and biochemical data revealedmore » good correlation between hepatic allograft function and Tc-NGA kinetics. Major kinetic alterations were noted during periods of preservation injury, hepatic infarction, and acute rejection. These studies indicate: (1) major alterations in Tc-NGA kinetics occur during preservation injury, hepatic infarction, and acute rejection, and (2) Tc-NGA kinetic data appear to provide an accurate reflection of hepatic allograft function. Tc-NGA imaging has the advantages of being noninvasive and of utilizing standard nuclear medicine instrumentation, including portable imaging devices. In conclusion, Tc-NGA imaging provides a promising noninvasive approach for evaluation of liver function in patients undergoing hepatic transplantation.« less

  2. Design and performance of an automated radionuclide separator: its application on the determination of ⁹⁹Tc in groundwater.

    PubMed

    Chung, Kun Ho; Choi, Sang Do; Choi, Geun Sik; Kang, Mun Ja

    2013-11-01

    A modular automated radionuclide separator for (99)Tc (MARS Tc-99) has been developed for the rapid and reproducible separation of technetium in groundwater samples. The control software of MARS Tc-99 was developed in the LabView programming language. An automated radiochemical method for separating (99)Tc was developed and validated by the purification of (99m)Tc tracer solution eluted from a commercial (99)Mo/(99m)Tc generator. The chemical recovery and analytical time for this radiochemical method were found to be 96 ± 2% and 81 min, respectively. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Intraoperative Localisation of Impalpable Breast Lesions Utilising the ROLLIS Technique Following Peritumoral 99mTc-colloid Sentinel Node Lymphoscintigraphy.

    PubMed

    Hung, Te-Jui; Burrage, John; Bourke, Anita; Taylor, Donna

    2017-08-24

    Ultrasound or stereotactic guided hook-wire localisation has been the standard-of-care for the pre-surgical localisation of impalpable breast lesions, which account for approximately a third of all breast cancer. Radioguided occult lesion localisation using I-125 seeds (ROLLIS) is a relatively new technique for guiding surgical excision of impalpable breast lesions, and is a promising alternative to the traditional hook-wire method. When combined with Tc-99m labelled colloid for sentinel node mapping in clinically indicated cases, there has been uncertainty regarding whether the downscatter of Tc-99m into the I-125 energy spectrum could adversely affect the intra-operative detection of the I-125 seed, especially pertaining to a peritumoral injection. To evaluate the percentage contribution of downscattered activity from Tc-99m into the I-125 energy spectrum in simulated intra-operative resections of an I-125 seed following different sentinel node injection techniques. Two scenarios were simulated using breast phantoms with lean chicken breast. The first scenario, with a 2cm distance between the Tc-99m injection site and the I-125 seed, simulated a periareolar ipsiquadrant injection with the subdermal or intradermal technique. The second scenario simulated a peritumoral injection technique with the Tc-99m bolus and an I-125 seed at the same site. Count rates were acquired with a hand-held gamma probe, and the percentage contribution of downscattered Tc-99m gamma photons to the I-125 energy window was calculated. In scenarios one and two, downscattered Tc-99m activity contributed 0.5% and 33% respectively to the detected count rate in the I-125 energy window. In both scenarios, the I-125 seed was successfully localised and removed using the gamma probe. There is no significant contribution of downscattered activity associated with a peritumoral injection of Tc-99m to adversely affect the accurate intra-operative localisation of an I- 125 seed. Copyright© Bentham

  4. Preclinical evaluation of 99mTc(CO)3-aspartic-N-monoacetic acid, 99mTc(CO)3(ASMA), a new renal radiotracer with pharmacokinetic properties comparable to 131I-OIH

    PubMed Central

    Lipowska, Malgorzata; Klenc, Jeffrey; Marzilli, Luigi G.; Taylor, Andrew T.

    2014-01-01

    In an ongoing effort to develop a renal tracer with pharmacokinetic properties comparable to PAH and superior to those of both 99mTc-MAG3 and 131I-OIH, we evaluated a new renal tricarbonyl radiotracer based on the aspartic-N-monoacetic acid ligand, 99mTc(CO)3(ASMA). The ASMA ligand features two carboxyl groups and an amine function for the coordination of the {99mTc(CO)3}+ core as well as a dangling carboxylate to facilitate rapid renal clearance. Methods rac-ASMA and L-ASMA were labeled with a 99mTc-tricarbonyl precursor and radiochemical purity of the labeled products was determined by HPLC. Using 131I-OIH as an internal control, we evaluated biodistribution in normal rats with 99mTc(CO)3(ASMA) isomers and in rats with renal pedicle ligation with 99mTc(CO)3(rac-ASMA). Clearance studies were conducted in 4 additional rats. In vitro radiotracer stability was determined in PBS buffer pH 7.4 and in challenge studies with cysteine and histidine. 99mTc(CO)3(ASMA) metabolites in urine were analyzed by HPLC. Results Both 99mTc(CO)3(ASMA) preparations had > 99% radiochemical purity and were stable in PBS buffer pH 7.4 for 24 h. Challenge studies on both revealed no significant displacement of the ligand. In normal rats, % injected dose in urine at 10 and 60 min for both preparations averaged 103% and 106% that of 131I-OIH, respectively. The renal clearances of 99mTc(CO)3(rac-ASMA) and 131I-OIH were comparable (P = 0.48). The tracer was excreted unchanged in the urine, proving its in vivo stability. In pedicle-ligated rats, 99mTc(CO)3(rac-ASMA) had less excretion into the bowel (P < 0.05) and was better retained in the blood (P < 0.05) than 131I-OIH. Conclusion Both 99mTc(CO)3(ASMA) complexes have pharmacokinetic properties in rats comparable to or superior to those of 131I-OIH, and human studies are warranted for their further evaluation. PMID:22717977

  5. Sentinel node mapping in endometrial cancer following Hysteroscopic injection of tracers: A single center evaluation over 200 cases.

    PubMed

    Martinelli, Fabio; Ditto, Antonino; Signorelli, Mauro; Bogani, Giorgio; Chiappa, Valentina; Lorusso, Domenica; Scaffa, Cono; Recalcati, Dario; Perotto, Stefania; Haeusler, Edward; Raspagliesi, Francesco

    2017-09-01

    To analyze detection-rate(DR) and diagnostic-accuracy (A) of sentinel-nodes(SLNs) mapping following hysteroscopic-injection of tracer. To compare DR and A between tracers: ICG and Tc99m. Evaluation of endometrial-cancer patients who underwent SLNs mapping after hysteroscopic-peritumoral-injection of tracer±lymphadenectomy. Analysis of DR (overall-bilateral-aortic) and A in the entire cohort and comparison between tracers. 202 procedures were performed from January/2005 to February/2017. Mean age:60years (28-82); mean BMI: 26.8 kg/m 2 (15-47). In 133 cases (65.8%) hysterectomy and mapping procedure were performed laparoscopically. The overall-DR of the technique was 93.2% (179/192) (10 cases were excluded: 9 for technical-equipment failure; 1 for vagal reaction). Bilateral pelvic mapping was found in 59.7% of cases (107/179) and was more frequent in the ICG group (72.8% vs 53.3%; p: 0.012). In 50.8% of cases (91/179) SLNs were mapped both in pelvic and aortic nodes, and in 5 cases (2.8%) only in the aortic area. The mean number of detected SLNs was 3.7 (1-8). 22 patients (12.3%) had nodal involvement: 10-(45.5%)-macrometastases; 5-(22.7%)-micrometastases; 7-(31.8%)-ITCs. In 6 cases (27.3%) only aortic nodes were positive; in 5 cases (22.7%) both pelvic and aortic nodes and in 11 cases (50%) only pelvic nodes were involved. Three false-negative results were found, all in the Tc99m group. All had isolated aortic metastases with negative pelvic nodes. Overall-sensitivity was 86.4% (95%CI: 68.4-100) and overall-negative-predictive-value (NPV) was 96.4% (95%CI 86.7-100). No differences in terms of overall-DR, overall-sensitivity and overall-NPV were found between the two tracers. Hysteroscopic-injection of tracer for SLNs mapping in endometrial cancer is as accurate as cervical injection with a higher DR in the aortic area. ICG improves bilateral-DR. Further investigation is warranted on this topic. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Pharmacokinetics of 99mTc-MAA- and 99mTc-HSA-Microspheres Used in Preradioembolization Dosimetry: Influence on the Liver-Lung Shunt.

    PubMed

    Grosser, Oliver S; Ruf, Juri; Kupitz, Dennis; Pethe, Annette; Ulrich, Gerhard; Genseke, Philipp; Mohnike, Konrad; Pech, Maciej; Richter, Wolf S; Ricke, Jens; Amthauer, Holger

    2016-06-01

    Perfusion scintigraphy using (99m)Tc-labeled albumin aggregates is mandatory before hepatic radioembolization with (90)Y-microspheres. As part of a prospective trial, the intrahepatic and intrapulmonary stability of 2 albumin compounds, (99m)Tc-MAA (macroaggregated serum albumin [MAA]) and (99m)Tc-HSA (human serum albumin [HSA]), was assessed. In 24 patients with metastatic colorectal cancer, biodistribution (liver, lung) and liver-lung shunt (LLS) of both tracers (12 patients each) were assessed by sequential planar scintigraphy (1, 5, and 24 h after injection). Liver uptake of both albumin compounds decreased differently. Although initial LLSs at 1 h after injection were similar in both groups, MAA-LLS increased significantly from 1 (3.9%) to 5 h (7.7%) and 24 h (9.9%) after injection, respectively. HSA-LLS did not change significantly (1 to 5 h), indicating a steady state of pulmonary and intrahepatic degradation. Compared with (99m)Tc-MAA-microspheres, (99m)Tc-HSA-microspheres are likely more resistant to degradation over time, allowing a reliable LLS determination even at later time points. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  7. Initial evaluation of 99m Tc-tricarbonyl-cyclopentadienyl fatty acids derivatives as SPECT tracers for myocardium.

    PubMed

    Liu, Jianping; Wang, Huan; Wang, Shuxia; Xue, Qianqian; Wang, Dawei; Wang, Hang; Zhang, Huabei

    2017-05-15

    Fatty acids are myocardial metabolic agent for detecting myocardial ischemia and infraction. However, no 99m Tc-labeled fatty acids had potential use in clinical practice. In this study, 99m Tc-CpTT-10-oxo-para-PPA (1d), 99m Tc-CpTT-11-oxo-para-PPA (2d), 99m Tc-CpTT-12-oxo-para-PPA (3d), 99m Tc-CpTT-11-oxo-ortho-PPA (4d), and 99m Tc-CpTT-11-oxo-meta-PPA (5d) were synthesized by a double ligand transfer reaction, and their biological behaviors were investigated. Compound 2d achieved good heart to blood ratio (3.39 at 5 min after intravenous), and 2d showed high-heart uptake of 6.20% ID/g at 5 minutes after injection. Compound 3d displayed a prolonged retention in the myocardium (1.43% ID/g at 60 min after injection). Radioactivity accumulation in the lungs, spleen, and blood was eliminated rapidly. In vivo, metabolite analysis presented that compound 6d may be metabolite of 2d through β-oxidation in tissue. Unfortunately, the biodistribution studies of 1d, 2d, 3d, 4d, and 5d showed fast heart clearance and poor heart to liver ratios, which suggested that the 5 99m Tc-labeled fatty acid analogues cannot be used for diagnosis. Copyright © 2017 John Wiley & Sons, Ltd.

  8. Single-sample 99mTc-diethylenetriamine penta-acetate plasma clearance in advanced renal failure by the mean sojourn time approach.

    PubMed

    Gref, Margareta C; Karp, Kjell H

    2009-03-01

    The single-sample Tc-diethylenetriamine penta-acetate (DTPA) clearance method by Christensen and Groth is recommended by the Radionuclides in Nephrourology Committee on Renal Clearance for use in adults with an estimated glomerular filtration rate (GFR) > or = 30 ml/min. The purpose of this study was to test a new Tc-DTPA single-sample low clearance formula for GFR lesser than 30 ml/min. Twenty-one adult patients (29 investigations) were included. Reference clearance was calculated with both Cr-EDTA and Tc-DTPA according to Brøchner-Mortensen with samples drawn between 3 and 24 h. Single-sample clearance was calculated from a 24 h sample using the low clearance formula(Equation is included in full-text article.) C(t) is the activity of the tracer in the plasma sample t minutes after the injection and Q0 is the injected amount. ECV is the extracellular volume in ml defined as the distribution volume of the tracer. ECV is estimated from the body surface area as ECV=8116.6xbody surface area-28.2. The mean difference between reference and Tc-DTPA single-sample clearance was -0.5 ml/min (SD 1.0 ml/min) for Tc-DTPA and -0.8 ml/min (SD 1.2 ml/min) for Cr-EDTA as reference clearance. In adult patients it is possible, even with GFR lesser than 30 ml/min, to get an accurate determination of Tc-DTPA plasma clearance from a single sample using the mean sojourn time approach. The blood sample should be obtained about 24 h after injection of the GFR tracer.

  9. ECT imaging with Tc(V)-99m dimercaptosuccinic acid useful to detect lung metastases of osteosarcoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ohta, H.; Ishii, M.; Yoshizumi, M.

    1985-01-01

    ECT imaging, using Tc(V)-99m dimercaptosuccinic acid (Tc(V)-DMS) was performed in two patients with lung metastasis of osteosarcoma, and the results were compared with those of CT scan. Clear accumulation of Tc(V)-DMS was recognized in all cases in the same area that CT scans demonstrated. Tc(V)-DMS was labeled under optimal pH 8, had very low SnCl/sub 2/ concentrations, an equilibrium between a stable form and a dissociated form of anion TcO/sub 4/(3-) structurally similar to PO/sub 4/(3-), and was postulated for tumor uptake. Considering this proposed mechanism for Tc(V)-DMS uptake by tumor cells, ECT imaging using this tracer could be ofmore » use in the early detection of lung metastasis of osteosarcoma.« less

  10. Characterizing Gas Transport in Wetland Soil-Root Systems with Dissolved Gas Tracer Techniques

    NASA Astrophysics Data System (ADS)

    Reid, M. C.; Jaffe, P. R.

    2016-12-01

    Soil fluxes of methane (CH4), nitrous oxide (N2O), and other biogenic gases depend on coupling between microbial and physiochemical processes within soil media. The importance of plant-mediated transport in wetland CH4 emissions is well known, but a generalized understanding of gas transfer between pore water and root aerenchyma, and how this process competes with biogeochemical production/consumption of gases beyond CH4, is incomplete [1]. A lack of experimental approaches to characterize transport processes in complex soil-water-plant systems at field scale has limited efforts to close this knowledge gap. In this presentation we describe dissolved gas tracer techniques to tease apart effects of transport from simultaneous biochemical reaction on trace gas dynamics in soils. We discuss a push-pull test with helium and sulfur hexafluoride gas tracers to quantify in situ root-mediated gas transfer kinetics in a wetland soil [2]. A Damköhler number analysis is introduced to interpret the results and evaluate the balance between biochemical reaction and root-driven gas transfer in controlling the fate of CH4 and N2O in vegetated wetland soils. We conclude with a brief discussion of other problems in soil gas dynamics that can be addressed with gas tracer approaches. [1] Blagodatsky and Smith 2012. Soil physics meets soil biology: Towards better mechanistic prediction of greenhouse gas emissions from soil. Soil Biology and Biochemistry 47, 78-92. [2] Reid et al. 2015. Dissolved gas dynamics in wetland soils: Root-mediated gas transfer kinetics determind via push-pull tracer tests. Water Resour. Res. 51, doi:10.1002/2014WR016803.

  11. Rapid Multi-Tracer PET Tumor Imaging With F-FDG and Secondary Shorter-Lived Tracers.

    PubMed

    Black, Noel F; McJames, Scott; Kadrmas, Dan J

    2009-10-01

    Rapid multi-tracer PET, where two to three PET tracers are rapidly scanned with staggered injections, can recover certain imaging measures for each tracer based on differences in tracer kinetics and decay. We previously showed that single-tracer imaging measures can be recovered to a certain extent from rapid dual-tracer (62)Cu - PTSM (blood flow) + (62)Cu - ATSM (hypoxia) tumor imaging. In this work, the feasibility of rapidly imaging (18)F-FDG plus one or two of these shorter-lived secondary tracers was evaluated in the same tumor model. Dynamic PET imaging was performed in four dogs with pre-existing tumors, and the raw scan data was combined to emulate 60 minute long dual- and triple-tracer scans, using the single-tracer scans as gold standards. The multi-tracer data were processed for static (SUV) and kinetic (K(1), K(net)) endpoints for each tracer, followed by linear regression analysis of multi-tracer versus single-tracer results. Static and quantitative dynamic imaging measures of FDG were both accurately recovered from the multi-tracer scans, closely matching the single-tracer FDG standards (R > 0.99). Quantitative blood flow information, as measured by PTSM K(1) and SUV, was also accurately recovered from the multi-tracer scans (R = 0.97). Recovery of ATSM kinetic parameters proved more difficult, though the ATSM SUV was reasonably well recovered (R = 0.92). We conclude that certain additional information from one to two shorter-lived PET tracers may be measured in a rapid multi-tracer scan alongside FDG without compromising the assessment of glucose metabolism. Such additional and complementary information has the potential to improve tumor characterization in vivo, warranting further investigation of rapid multi-tracer techniques.

  12. Coordination modes of multidentate ligands in fac-[Re(CO)(3)(polyaminocarboxylate)] analogues of (99m)Tc radiopharmaceuticals. dependence on aqueous solution reaction conditions.

    PubMed

    Lipowska, Malgorzata; He, Haiyang; Xu, Xiaolong; Taylor, Andrew T; Marzilli, Patricia A; Marzilli, Luigi G

    2010-04-05

    We study Re analogues of (99m)Tc renal agents to interpret previous results at the (99m)Tc tracer level. The relative propensities of amine donors versus carboxylate oxygen donors of four L = polyaminocarboxylate ligands to coordinate in fac-[Re(I)(CO)(3)L](n) complexes were assessed by examining the reaction of fac-[Re(I)(CO)(3)(H(2)O)(3)](+) under conditions differing in acidity and temperature. All four L [N,N-bis-(2-aminoethyl)glycine (DTGH), N,N-ethylenediaminediacetic acid, diethylenetriamine-N-malonic acid, and diethylenetriamine-N-acetic acid] can coordinate as tridentate ligands while creating a dangling chain terminated in a carboxyl group. Dangling carboxyl groups facilitate renal clearance in fac-[(99m)Tc(I)(CO)(3)L](n) agents. Under neutral conditions, the four ligands each gave two fac-[Re(I)(CO)(3)L](n) products with HPLC traces correlating well with known traces of the fac-[(99m)Tc(I)(CO)(3)L](n) mixtures. Such mixtures are common in renal agents because the needed dangling carboxyl group can compete for a coordination site. However, the HPLC separations needed to assess the biodistribution of a single tracer are impractical in a clinical setting. One goal in investigating this Re chemistry is to identify conditions for avoiding this problem of mixtures in preparations of fac-[(99m)Tc(I)(CO)(3)L](n) renal tracers. After separation and isolation of the fac-[Re(I)(CO)(3)L](n) products, NMR analysis of all products and single crystal X-ray crystallographic analysis of both DTGH products, as well as one product each from the other L, allowed us to establish coordination mode unambiguously. The product favored in acidic conditions has a dangling amine chain and more bound oxygen. The product favored in basic conditions has a dangling carboxyl chain and more bound nitrogen. At the elevated temperatures used for simulating tracer preparation, equilibration was facile (ca. 1 h or less), allowing selective formation of one product by utilizing acidic or

  13. Improved Quantification of the Beta Cell Mass after Pancreas Visualization with 99mTc-demobesin-4 and Beta Cell Imaging with 111In-exendin-3 in Rodents.

    PubMed

    van der Kroon, Inge; Joosten, Lieke; Nock, Berthold A; Maina, Theodosia; Boerman, Otto C; Brom, Maarten; Gotthardt, Martin

    2016-10-03

    Accurate assessment of the 111 In-exendin-3 uptake within the pancreas requires exact delineation of the pancreas, which is highly challenging by MRI and CT in rodents. In this study, the pancreatic tracer 99m Tc-demobesin-4 was evaluated for accurate delineation of the pancreas to be able to accurately quantify 111 In-exendin-3 uptake within the pancreas. Healthy and alloxan-induced diabetic Brown Norway rats were injected with the pancreatic tracer 99m Tc-demobesin-4 ([ 99m Tc-N 4 -Pro 1 ,Tyr 4 ,Nle 14 ]bombesin) and the beta cell tracer 111 In-exendin-3 ([ 111 In-DTPA-Lys 40 ]exendin-3). After dual isotope acquisition of SPECT images, 99m Tc-demobesin-4 was used to define a volume of interest for the pancreas in SPECT images subsequently the 111 In-exendin-3 uptake within this region was quantified. Furthermore, biodistribution and autoradiography were performed in order to gain insight in the distribution of both tracers in the animals. 99m Tc-demobesin-4 showed high accumulation in the pancreas. The uptake was highly homogeneous throughout the pancreas, independent of diabetic status, as demonstrated by autoradiography, whereas 111 In-exendin-3 only accumulates in the islets of Langerhans. Quantification of both ex vivo and in vivo SPECT images resulted in an excellent linear correlation between the pancreatic uptake, determined with ex vivo counting and 111 In-exendin-3 uptake, determined from the quantitative analysis of the SPECT images (Pearson r = 0.97, Pearson r = 0.92). 99m Tc-demobesin-4 shows high accumulation in the pancreas of rats. It is a suitable tracer for accurate delineation of the pancreas and can be conveniently used for simultaneous acquisition with 111 In labeled exendin-3. This method provides a straightforward, reliable, and objective method for preclinical beta cell mass (BCM) quantification with 111 In-exendin-3.

  14. E-tracers: A New Technique for Wireless Sensing Under Ice Sheets

    NASA Astrophysics Data System (ADS)

    Burrow, S.; Wadham, J. L.; Salter, M.; Barnes, R.

    2009-12-01

    A significant hurdle to the understanding of ice sheet basal hydrology and its coupling with ice motion is the difficulty in making in-situ measurements along a flow path. While dye tracing techniques may be used in small glaciers to determine transit times of surface melt water through the sub-glacial system, they provide no information on in situ conditions (e.g. pressure) and are ineffective at ice-sheet scale where dilution is high. The use of tethered sensor packages is complicated by the long lengths (~100’s m) and torturous path of the moulins and conduits within ice sheets. Recent attempts to pass solid objects (rubber ducks) and other sensor packages through glacial moulins have confirmed the difficultly in deploying sensors into the sub glacial environment. Here, we report the first successful deployment and recovery of compact, electronic units to moulins up to 7 km from the margin of a large land-terminating Greenland outlet. The technique uses RF (Radio Frequency) location to create an electronic tracer (an ‘e-tracer’) enabling a data-logging sensor package to be located in the pro-glacial flood plain once it has passed through the ice sheet. A number of individual packages are used in each deployment mitigating for the risk that some may become stuck within the moulin or lodge in an inaccessible part of the floodplain. In preliminary tests on the Leverett glacier in West Greenland during August 2009 we have demonstrated that this technique can be used to locate and retrieve dummy sensor packages: 50% and 20% of the dummy sensor packages introduced to moulins at 1 and 7 km from the ice sheet terminus respectively, emerged in the sub-glacial stream. It was possible to effectively detect the e-tracer units (which broadcast on 151MHz with 10mW of power) over a horizontal range of up to 5km across the pro-glacial floodplain and locate them to a high accuracy, allowing visual recognition and manual recovery. These performance statistics give this

  15. Feasibility and diagnostic performance of dual-tracer-guided sentinel lymph node biopsy in cT1-2N0M0 gastric cancer: a systematic review and meta-analysis of diagnostic studies.

    PubMed

    Huang, Ling; Wei, Tao; Chen, Junjun; Zhou, Donghui

    2017-05-16

    Dual-tracer-guided sentinel lymph node (SLN) biopsy may provide a promising diagnostic tool to assess accurately the status of lymph node metastasis in the surgical operation and assure the oncologic safety of the function or stomach preserving surgery. The diagnostic performance of this technology in recent studies varied. Thus, we conducted this meta-analysis. This systematic review and meta-analysis was registered at the PROSPERO. Eligible studies were searched in the PubMed, EMBASE, Web of Knowledge, and Cochrane Library databases. A random-effect model was used to pool the data. Summary receiver operator characteristic curves, analysis for publication bias, meta-regression, and subgroup analysis were also performed. The pooled SLN identification rate and sensitivity were 0.97 and 0.89. 99m Tc-human serum albumin with indocyanine green (ICG), 99m Tc-antimony sulfur colloid with ICG, performing SLN biopsy ≥15 min after dye injection, an SLN ≥5, the basin dissection, laparoscopic surgery, in studies conducted in Japan and studies published after 2012, were associated with higher sensitivity. CT1 stage, performing SLN biopsy ≥15 min after dye injection, in studies conducted in Japan and studies published after 2012, were related with a higher identification rate. Dual tracer is promising in SLN biopsy in gastric cancer, and the clinical application of SLN biopsy should be limited to the patients of cT1N0M0 gastric cancer. The combination of 99m Tc-human serum albumin and ICG as well as the combination of 99m Tc-antimony sulfur colloid and ICG may be the optimal tracer combination. However, it seems not justified to put this technique into routine clinical application recently. Some factors that might enhance diagnostic value are identified.

  16. Rapid Multi-Tracer PET Tumor Imaging With 18F-FDG and Secondary Shorter-Lived Tracers

    PubMed Central

    Black, Noel F.; McJames, Scott; Kadrmas, Dan J.

    2009-01-01

    Rapid multi-tracer PET, where two to three PET tracers are rapidly scanned with staggered injections, can recover certain imaging measures for each tracer based on differences in tracer kinetics and decay. We previously showed that single-tracer imaging measures can be recovered to a certain extent from rapid dual-tracer 62Cu – PTSM (blood flow) + 62Cu — ATSM (hypoxia) tumor imaging. In this work, the feasibility of rapidly imaging 18F-FDG plus one or two of these shorter-lived secondary tracers was evaluated in the same tumor model. Dynamic PET imaging was performed in four dogs with pre-existing tumors, and the raw scan data was combined to emulate 60 minute long dual- and triple-tracer scans, using the single-tracer scans as gold standards. The multi-tracer data were processed for static (SUV) and kinetic (K1, Knet) endpoints for each tracer, followed by linear regression analysis of multi-tracer versus single-tracer results. Static and quantitative dynamic imaging measures of FDG were both accurately recovered from the multi-tracer scans, closely matching the single-tracer FDG standards (R > 0.99). Quantitative blood flow information, as measured by PTSM K1 and SUV, was also accurately recovered from the multi-tracer scans (R = 0.97). Recovery of ATSM kinetic parameters proved more difficult, though the ATSM SUV was reasonably well recovered (R = 0.92). We conclude that certain additional information from one to two shorter-lived PET tracers may be measured in a rapid multi-tracer scan alongside FDG without compromising the assessment of glucose metabolism. Such additional and complementary information has the potential to improve tumor characterization in vivo, warranting further investigation of rapid multi-tracer techniques. PMID:20046800

  17. Effects of CT-based attenuation correction of rat microSPECT images on relative myocardial perfusion and quantitative tracer uptake

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strydhorst, Jared H., E-mail: jared.strydhorst@gmail.com; Ruddy, Terrence D.; Wells, R. Glenn

    2015-04-15

    Purpose: Our goal in this work was to investigate the impact of CT-based attenuation correction on measurements of rat myocardial perfusion with {sup 99m}Tc and {sup 201}Tl single photon emission computed tomography (SPECT). Methods: Eight male Sprague-Dawley rats were injected with {sup 99m}Tc-tetrofosmin and scanned in a small animal pinhole SPECT/CT scanner. Scans were repeated weekly over a period of 5 weeks. Eight additional rats were injected with {sup 201}Tl and also scanned following a similar protocol. The images were reconstructed with and without attenuation correction, and the relative perfusion was analyzed with the commercial cardiac analysis software. The absolutemore » uptake of {sup 99m}Tc in the heart was also quantified with and without attenuation correction. Results: For {sup 99m}Tc imaging, relative segmental perfusion changed by up to +2.1%/−1.8% as a result of attenuation correction. Relative changes of +3.6%/−1.0% were observed for the {sup 201}Tl images. Interscan and inter-rat reproducibilities of relative segmental perfusion were 2.7% and 3.9%, respectively, for the uncorrected {sup 99m}Tc scans, and 3.6% and 4.3%, respectively, for the {sup 201}Tl scans, and were not significantly affected by attenuation correction for either tracer. Attenuation correction also significantly increased the measured absolute uptake of tetrofosmin and significantly altered the relationship between the rat weight and tracer uptake. Conclusions: Our results show that attenuation correction has a small but statistically significant impact on the relative perfusion measurements in some segments of the heart and does not adversely affect reproducibility. Attenuation correction had a small but statistically significant impact on measured absolute tracer uptake.« less

  18. Journal: Efficient Hydrologic Tracer-Test Design for Tracer-Mass Estimation and Sample Collection Frequency, 1 Method Development

    EPA Science Inventory

    Hydrological tracer testing is the most reliable diagnostic technique available for the determination of basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test design can be difficult because of a lack of prior knowl...

  19. 99mTc Glucarate as a Potential Radiopharmaceutical Agent for Assessment of Tumor Viability: From Bench to the Bed Side

    PubMed Central

    Choudhury, Partha S.; Savio, E.; Solanki, K. K.; Alonso, O.; Gupta, A.; Gambini, J. P.; Doval, Dinesh; Sharma, P.; Dondi, M.

    2012-01-01

    Several radiotracers have been used for assessing cell death, whether by necrosis or apoptosis. 99mTc glucarate, which has initially been reported to be concentrating/accumulating in myocardial infarction or zones of cerebral injury, has also shown some tumor-seeking properties in a few preliminary studies. Under International Atomic Energy Agency (IAEA)'s coordinated research program, we report here the standardization, quality control, and clinical evaluation (detection, evaluation of response, and comparison with 18F Fluorodeoxyglucose) of this tracer in well-characterized lung cancer and head neck malignancies in a single-arm prospective observational study. Forty-seven patients (29 inoperable lung carcinoma and 18 head and neck malignancies) were prospectively enrolled and underwent 99mTc glucarate imaging [whole body planar and single-photon emission computed tomography of the region of interest] 4-5 hours after injection of 20 mCi of the radiopharmaceutical. Excellent 99mTc glucarate concentration was noted in the target lesion in lung cancer and head and neck malignancies. The sensitivity was found to be better in lung cancer. Avid concentration of tracer was seen in the metastatic sites. During response evaluation, the glucarate concentration correlated well with the clinical and other radiological findings. 99mTc glucarate showed avid concentration of tracer in the tumor, suggesting it to be a potential tumor imaging agent which can be used for detection and assessment of therapeutic response in malignancy. PMID:23372437

  20. Comparison of LDPI to SPECT perfusion imaging using (99m)Tc-sestamibi and (99m)Tc-pyrophosphate in a murine ischemic hind limb model of neovascularization.

    PubMed

    Hendrikx, Geert; Vries, Mark H; Bauwens, Matthias; De Saint-Hubert, Marijke; Wagenaar, Allard; Guillaume, Joël; Boonen, Levinia; Post, Mark J; Mottaghy, Felix M

    2016-12-01

    We aimed to determine the accuracy of laser Doppler perfusion imaging (LDPI) in an animal model for hind limb ischemia. We used a murine (C57Bl/6 mice) ischemic hind limb model in which we compared LDPI with the clinically used (99m)Tc-sestamibi SPECT perfusion imaging (n = 7). In addition, we used the SPECT tracer (99m)Tc-pyrophosphate ((99m)Tc-PyP) to image muscular damage (n = 6). LDPI indicated a quick and prominent decrease in perfusion immediately after ligation, subsequently recovering to 21.9 and 25.2 % 14 days later in the (99m)Tc-sestamibi and (99m)Tc-PyP group, respectively. (99m)Tc-sestamibi SPECT scans also showed a quick decrease in perfusion. However, nearly full recovery was reached 7 days post ligation. Muscular damage, indicated by the uptake of (99m)Tc-PyP, was highest at day 3 and recovered to baseline levels at day 14 post ligation. Postmortem histology supported these findings, as a significantly increased collateral diameter was found 7 and 14 days after ligation and peak macrophage infiltration and TUNEL positivity was found on day 3 after ligation. Here, we indicate that LDPI strongly underestimates perfusion recovery in a hind limb model for profound ischemia.

  1. Statistical atmospheric inversion of local gas emissions by coupling the tracer release technique and local-scale transport modelling: a test case with controlled methane emissions

    NASA Astrophysics Data System (ADS)

    Ars, Sébastien; Broquet, Grégoire; Yver Kwok, Camille; Roustan, Yelva; Wu, Lin; Arzoumanian, Emmanuel; Bousquet, Philippe

    2017-12-01

    This study presents a new concept for estimating the pollutant emission rates of a site and its main facilities using a series of atmospheric measurements across the pollutant plumes. This concept combines the tracer release method, local-scale atmospheric transport modelling and a statistical atmospheric inversion approach. The conversion between the controlled emission and the measured atmospheric concentrations of the released tracer across the plume places valuable constraints on the atmospheric transport. This is used to optimise the configuration of the transport model parameters and the model uncertainty statistics in the inversion system. The emission rates of all sources are then inverted to optimise the match between the concentrations simulated with the transport model and the pollutants' measured atmospheric concentrations, accounting for the transport model uncertainty. In principle, by using atmospheric transport modelling, this concept does not strongly rely on the good colocation between the tracer and pollutant sources and can be used to monitor multiple sources within a single site, unlike the classical tracer release technique. The statistical inversion framework and the use of the tracer data for the configuration of the transport and inversion modelling systems should ensure that the transport modelling errors are correctly handled in the source estimation. The potential of this new concept is evaluated with a relatively simple practical implementation based on a Gaussian plume model and a series of inversions of controlled methane point sources using acetylene as a tracer gas. The experimental conditions are chosen so that they are suitable for the use of a Gaussian plume model to simulate the atmospheric transport. In these experiments, different configurations of methane and acetylene point source locations are tested to assess the efficiency of the method in comparison to the classic tracer release technique in coping with the distances

  2. Synthesis and evaluation of (99m)Tc chelate-conjugated bevacizumab.

    PubMed

    Camacho, Ximena; García, María Fernanda; Calzada, Victoria; Fernández, Marcelo; Porcal, Williams; Alonso, Omar; Gambini, Juan Pablo; Cabral, Pablo

    2013-03-01

    Vascular endothelial growth factor (VEGF) is one of the classic factors involved in tumor-induced angiognesis in several solid tumors. Bevacizumab, a monoclonal antibody against VEGF, can be used as an imaging tool in preclinical studies. The aim of this study was to radiolabel Bevacizumab with (99m)Tc and to evaluate in vivo its imaging properties in an adenocarcinoma animal model. For this purpose, Bevacizumab was derivatized with Suc-HYNIC as a bifunctional coupling agent. A mixture of Tricine/SnCl(2).2H(2)O was added to Bevacizumab-HYNIC and radiolabeled with (99m)TcO(4)(-). The radiochemical stability of the radiolabeled antibody was assessed. Biodistribution and scintigraphy imaging were performed in normal CD1 female mice and in spontaneous adenocarcinoma tumor bearing CD1 mice (n = 5). We demonstrated that 99mTc-HYNIC-Bevacizumab was stable. In vivo biodistribution studies revealed that tumor uptake of (99m)Tc-HYNIC-Bevacizumab was 1.37 ± 0.51% and 5.33 ± 2.13% at 4 and 24 h postinjection, respectively. Scintigraphy image studies showed tumor selective uptake of (99m)Tc-HYNIC-Bevacizumab in the tumor-bearing mice. We conclude that (99m)Tc-HYNIC-Bevacizumb has the potential to be used as a tracer for tumor imaging in preclinical studies.

  3. Hydrometeor Trajectories and Distributions in a Simulation of TC Rapid Intensification (RI)

    NASA Astrophysics Data System (ADS)

    Zhu, Z.; Zhu, P.

    2010-12-01

    It has long been recognized that the microphysics scheme used in a numerical simulation of tropical cyclones (TC) can greatly affect the precipitation distribution, intensity and thermodynamic structure of the simulated TC. This suggests that the mixing ratios, concentrations and size distributions of hydrometeor(snow, graupel,rain,cloud ice) are important factors in the evolution of TC . The transport of hydrometeor may have a strong influence on these factors through its interactions with the growth and the latent heat forcing of hydrometeor and the wind filed, hence is a key to understanding TC microphysics. Schematic hydrometeor trajectories were first constructed using 3-D wind field and particle fallspeeds derived from airborne radar observations in a steady-state mature hurricane,Alicia(1983). Since then, little effort has been put in understanding hydrometeor transport in TC, especially the potential link between its evolution and the intensity and structure changes in a non-steady-state TC. This study is focused on investigating such a link by means of numerical simulations of TC Rapid Intensification(RI) using WRF model. We use the tracer utility in WRF to construct hydrometeor trajectories. Most of the popular microphysics schemes are tested, and the most reasonable test( which is determined by comparing the simulated TC intensity and structure with airborne radar observations) and the ensemble mean of all the tests are picked for detailed examinations.

  4. A Comparison of Several Techniques to Assign Heights to Cloud Tracers.

    NASA Astrophysics Data System (ADS)

    Nieman, Steven J.; Schmetz, Johannes; Menzel, W. Paul

    1993-09-01

    Satellite-derived cloud-motion vector (CMV) production has been troubled by inaccurate height assignment of cloud tracers, especially in thin semitransparent clouds. This paper presents the results of an intercomparison of current operational height assignment techniques. Currently, heights are assigned by one of three techniques when the appropriate spectral radiance measurements are available. The infrared window (IRW) technique compares measured brightness temperatures to forecast temperature profiles and thus infers opaque cloud levels. In semitransparent or small subpixel clouds, the carbon dioxide (CO2) technique uses the ratio of radiances from different layers of the atmosphere to infer the correct cloud height. In the water vapor (H2O) technique, radiances influenced by upper-tropospheric moisture and IRW radiances are measured for several pixels viewing different cloud amounts, and their linear relationship is used to extrapolate the correct cloud height. The results presented in this paper suggest that the H2O technique is a viable alternative to the CO2 technique for inferring the heights of semitransparent cloud elements. This is important since future National Environmental Satellite, Data, and Information Service (NESDIS) operations will have to rely on H20-derived cloud-height assignments in the wind field determinations with the next operational geostationary satellite. On a given day, the heights from the two approaches compare to within 60 110 hPa rms; drier atmospheric conditions tend to reduce the effectiveness of the H2O technique. By inference one can conclude that the present height algorithms used operationally at NESDIS (with the C02 technique) and at the European Satellite Operations Center (ESOC) (with their version of the H20 technique) are providing similar results. Sample wind fields produced with the ESOC and NESDIS algorithms using Meteosat-4 data show good agreement.

  5. Methodology for quantitative rapid multi-tracer PET tumor characterizations.

    PubMed

    Kadrmas, Dan J; Hoffman, John M

    2013-10-04

    Positron emission tomography (PET) can image a wide variety of functional and physiological parameters in vivo using different radiotracers. As more is learned about the molecular basis for disease and treatment, the potential value of molecular imaging for characterizing and monitoring disease status has increased. Characterizing multiple aspects of tumor physiology by imaging multiple PET tracers in a single patient provides additional complementary information, and there is a significant body of literature supporting the potential value of multi-tracer PET imaging in oncology. However, imaging multiple PET tracers in a single patient presents a number of challenges. A number of techniques are under development for rapidly imaging multiple PET tracers in a single scan, where signal-recovery processing algorithms are employed to recover various imaging endpoints for each tracer. Dynamic imaging is generally used with tracer injections staggered in time, and kinetic constraints are utilized to estimate each tracers' contribution to the multi-tracer imaging signal. This article summarizes past and ongoing work in multi-tracer PET tumor imaging, and then organizes and describes the main algorithmic approaches for achieving multi-tracer PET signal-recovery. While significant advances have been made, the complexity of the approach necessitates protocol design, optimization, and testing for each particular tracer combination and application. Rapid multi-tracer PET techniques have great potential for both research and clinical cancer imaging applications, and continued research in this area is warranted.

  6. Methodology for Quantitative Rapid Multi-Tracer PET Tumor Characterizations

    PubMed Central

    Kadrmas, Dan J.; Hoffman, John M.

    2013-01-01

    Positron emission tomography (PET) can image a wide variety of functional and physiological parameters in vivo using different radiotracers. As more is learned about the molecular basis for disease and treatment, the potential value of molecular imaging for characterizing and monitoring disease status has increased. Characterizing multiple aspects of tumor physiology by imaging multiple PET tracers in a single patient provides additional complementary information, and there is a significant body of literature supporting the potential value of multi-tracer PET imaging in oncology. However, imaging multiple PET tracers in a single patient presents a number of challenges. A number of techniques are under development for rapidly imaging multiple PET tracers in a single scan, where signal-recovery processing algorithms are employed to recover various imaging endpoints for each tracer. Dynamic imaging is generally used with tracer injections staggered in time, and kinetic constraints are utilized to estimate each tracers' contribution to the multi-tracer imaging signal. This article summarizes past and ongoing work in multi-tracer PET tumor imaging, and then organizes and describes the main algorithmic approaches for achieving multi-tracer PET signal-recovery. While significant advances have been made, the complexity of the approach necessitates protocol design, optimization, and testing for each particular tracer combination and application. Rapid multi-tracer PET techniques have great potential for both research and clinical cancer imaging applications, and continued research in this area is warranted. PMID:24312149

  7. 99mTc Labeled Glucagon-Like Peptide-1-Analogue (99mTc-GLP1) Scintigraphy in the Management of Patients with Occult Insulinoma

    PubMed Central

    Sowa-Staszczak, Anna; Trofimiuk-Müldner, Małgorzata; Stefańska, Agnieszka; Tomaszuk, Monika; Buziak-Bereza, Monika; Gilis-Januszewska, Aleksandra; Jabrocka-Hybel, Agata; Głowa, Bogusław; Małecki, Maciej; Bednarczuk, Tomasz; Kamiński, Grzegorz; Kowalska, Aldona; Mikołajczak, Renata; Janota, Barbara; Hubalewska-Dydejczyk, Alicja

    2016-01-01

    Introduction The aim of this study was to assess the utility of [Lys40(Ahx-HYNIC-99mTc/EDDA)NH2]-exendin-4 scintigraphy in the management of patients with hypoglycemia, particularly in the detection of occult insulinoma. Materials and Methods Forty patients with hypoglycemia and increased/confusing results of serum insulin and C-peptide concentration and negative/inconclusive results of other imaging examinations were enrolled in the study. In all patients GLP-1 receptor imaging was performed to localise potential pancreatic lesions. Results Positive results of GLP-1 scintigraphy were observed in 28 patients. In 18 patients postsurgical histopathological examination confirmed diagnosis of insulinoma. Two patients had contraindications to the surgery, one patient did not want to be operated. One patient, who presented with postprandial hypoglycemia, with positive result of GLP-1 imaging was not qualified for surgery and is in the observational group. Eight patients were lost for follow up, among them 6 patients with positive GLP-1 scintigraphy result. One patient with negative scintigraphy was diagnosed with malignant insulinoma. In two patients with negative scintigraphy Munchausen syndrome was diagnosed (patients were taking insulin). Other seven patients with negative results of 99mTcGLP-1 scintigraphy and postprandial hypoglycemia with C-peptide and insulin levels within the limits of normal ranges are in the observational group. We would like to mention that 99mTc-GLP1-SPECT/CT was also performed in 3 pts with nesidioblastosis (revealing diffuse tracer uptake in two and a focal lesion in one case) and in two patients with malignant insulinoma (with the a focal uptake in the localization of a removed pancreatic headin one case and negative GLP-1 1 scintigraphy in the other patient). Conclusions 99mTc-GLP1-SPECT/CT could be helpful examination in the management of patients with hypoglycemia enabling proper localization of the pancreatic lesion and effective

  8. Determination of stream reaeration coefficients by use of tracers

    USGS Publications Warehouse

    Kilpatrick, F.A.; Rathbun, R.E.; Yotsukura, N.; Parker, G.W.; DeLong, L.L.

    1987-01-01

    Stream reaeration is the physical absorption of oxygen from the atmosphere by a flowing stream. This is the primary process by which a stream replenishes the oxygen consumed in the biodegradation of organic wastes.Prior to 1965, reaeration rate coefficients could be estimated only by indirect methods. In 1965, a direct method of measuring stream reaeration coefficients was developed in which a radioactive tracer gas was injected into a stream--the tracer gas being desorbed from the stream inversely to how oxygen would be absorbed. The technique has since been modified by substituting hydrocarbon gases for the radioactive tracer gas.This manual describes the slug-injection and constant-rate injection methods of performing gas-tracer desorption measurements. Emphasis is on the use of rhodamine WT dye as a relatively conservative tracer and propane as the nonconservative gas tracer, on planning field tests, methods of injection, sampling and analysis, and computational techniques to compute desorption and reaeration coefficients.

  9. Determination of stream reaeration coefficients by use of tracers

    USGS Publications Warehouse

    Kilpatrick, F.A.; Rathbun, R.E.; Yotsukura, Nobuhiro; Parker, G.W.; DeLong, L.L.

    1989-01-01

    Stream reaeration is the physical absorption of oxygen from the atmosphere by a flowing stream. This is the primary process by which a stream replenishes the oxygen consumed in the biodegradation of organic wastes. Prior to 1965, reaeration rate coefficients could be estimated only by indirect methods. In 1965, a direct method of measuring stream reaeration coefficients was developed whereby a radioactive tracer gas was injected into a stream-the principle being that the tracer gas would be desorbed from the stream inversely to how oxygen would be absorbed. The technique has since been modified by substituting hydrocarbon gases for the radioactive tracer gas. This manual describes the slug-injection and constant-rate-injection methods of measuring gas-tracer desorption. Emphasis is on the use of rhodamine WT dye as a relatively conservative tracer and propane as the nonconservative gas tracer, on planning field tests, on methods of injection, sampling, and analysis, and on techniques for computing desorption and reaeration coefficients.

  10. Improving Marine Ecosystem Models with Biochemical Tracers

    NASA Astrophysics Data System (ADS)

    Pethybridge, Heidi R.; Choy, C. Anela; Polovina, Jeffrey J.; Fulton, Elizabeth A.

    2018-01-01

    Empirical data on food web dynamics and predator-prey interactions underpin ecosystem models, which are increasingly used to support strategic management of marine resources. These data have traditionally derived from stomach content analysis, but new and complementary forms of ecological data are increasingly available from biochemical tracer techniques. Extensive opportunities exist to improve the empirical robustness of ecosystem models through the incorporation of biochemical tracer data and derived indices, an area that is rapidly expanding because of advances in analytical developments and sophisticated statistical techniques. Here, we explore the trophic information required by ecosystem model frameworks (species, individual, and size based) and match them to the most commonly used biochemical tracers (bulk tissue and compound-specific stable isotopes, fatty acids, and trace elements). Key quantitative parameters derived from biochemical tracers include estimates of diet composition, niche width, and trophic position. Biochemical tracers also provide powerful insight into the spatial and temporal variability of food web structure and the characterization of dominant basal and microbial food web groups. A major challenge in incorporating biochemical tracer data into ecosystem models is scale and data type mismatches, which can be overcome with greater knowledge exchange and numerical approaches that transform, integrate, and visualize data.

  11. An intrapatient comparison of 99mTc-EDDA/HYNIC-TOC with 111In-DTPA-octreotide for diagnosis of somatostatin receptor-expressing tumors.

    PubMed

    Gabriel, Michael; Decristoforo, Clemens; Donnemiller, Eveline; Ulmer, Hanno; Watfah Rychlinski, Christine; Mather, Stephen J; Moncayo, Roy

    2003-05-01

    The aim of this study was to compare the imaging abilities of the recently developed somatostatin analog, (99m)Tc-hydrazinonicotinyl-Tyr(3)-octreotide ((99m)Tc-HYNIC-TOC [(99m)Tc-TOC]), with (111)In-diethylenediaminepentaacetic acid-D-Phe(1)-octreotide ((111)In-OCT [Octreoscan]) in patients undergoing routine somatostatin receptor (SSTR) scintigraphy. Forty-one patients (20 men, 21 women; age range, 29-75 y; mean age, 56.7 y) with either histologically proven or biologically and clinically suspected endocrine tumors were enrolled in the study. Four groups were distinguished: (a) patients being evaluated for the detection and localization of neuroendocrine tumors (n = 6), (b) tumor staging (n = 19), (c) patients being investigated to determine the SSTR status of tumor lesions (n = 11), and (d) patient follow-up studies (n = 5). Each patient received a mean activity of 150 MBq (111)In-OCT and 350-400 MBq (99m)Tc-TOC. Scintigraphy with (99m)Tc-TOC was performed 4 h after injection and scintigraphy with (111)In-OCT was performed 4 and 24 h after injection. SPECT studies of areas of interest were performed 4 h after injection for both tracers as well as at 24 h after injection for (111)In-OCT. The time interval between the studies using each tracer ranged from 2 to 22 d (mean interval, 9.3 d). (111)In-OCT and (99m)Tc-TOC showed an equivalent scan result in 32 patients (78%), 9 cases showed discrepancies (22%), false-negative results with (111)In-OCT were seen in 6 cases (14.6%), whereas (99m)Tc-TOC was false-positive in 2 cases (4.9%). (111)In-OCT was true-negative in both cases. The false-positive findings of the (99m)Tc-TOC studies were caused by nonspecific uptake in the bowel. In 1 case, (99m)Tc-TOC correctly identified a metastasis in the lumbar spine but both scan results were false-positive because of an inflammatory process. In 21 patients with SSTR-expressing tumors, the semiquantitative region-of-interest analysis showed that (99m)Tc-TOC achieved higher tumor

  12. EFFICIENT HYDROLOGICAL TRACER-TEST DESIGN (EHTD ...

    EPA Pesticide Factsheets

    Hydrological tracer testing is the most reliable diagnostic technique available for establishing flow trajectories and hydrologic connections and for determining basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test design can be difficult because of a lack of prior knowledge of the basic hydraulic and geometric parameters desired and the appropriate tracer mass to release. A new efficient hydrologic tracer-test design (EHTD) methodology has been developed that combines basic measured field parameters (e.g., discharge, distance, cross-sectional area) in functional relationships that describe solute-transport processes related to flow velocity and time of travel. The new method applies these initial estimates for time of travel and velocity to a hypothetical continuously stirred tank reactor as an analog for the hydrologic flow system to develop initial estimates for tracer concentration and axial dispersion, based on a preset average tracer concentration. Root determination of the one-dimensional advection-dispersion equation (ADE) using the preset average tracer concentration then provides a theoretical basis for an estimate of necessary tracer mass.Application of the predicted tracer mass with the hydraulic and geometric parameters in the ADE allows for an approximation of initial sample-collection time and subsequent sample-collection frequency where a maximum of 65 samples were determined to

  13. Performance of TcI/TcVI/TcII Chagas-Flow ATE-IgG2a for universal and genotype-specific serodiagnosis of Trypanosoma cruzi infection

    PubMed Central

    Alessio, Glaucia Diniz; de Araújo, Fernanda Fortes; Côrtes, Denise Fonseca; Sales Júnior, Policarpo Ademar; Lima, Daniela Cristina; Gomes, Matheus de Souza; do Amaral, Laurence Rodrigues; Xavier, Marcelo Antônio Pascoal; Teixeira-Carvalho, Andréa; Martins-Filho, Olindo Assis; de Lana, Marta

    2017-01-01

    Distinct Trypanosoma cruzi genotypes have been considered relevant for patient management and therapeutic response of Chagas disease. However, typing strategies for genotype-specific serodiagnosis of Chagas disease are still unavailable and requires standardization for practical application. In this study, an innovative TcI/TcVI/TcII Chagas Flow ATE-IgG2a technique was developed with applicability for universal and genotype-specific diagnosis of T. cruzi infection. For this purpose, the reactivity of serum samples (percentage of positive fluorescent parasites-PPFP) obtained from mice chronically infected with TcI/Colombiana, TcVI/CL or TcII/Y strain as well as non-infected controls were determined using amastigote-AMA, trypomastigote-TRYPO and epimastigote-EPI in parallel batches of TcI, TcVI and TcII target antigens. Data demonstrated that “α-TcII-TRYPO/1:500, cut-off/PPFP = 20%” presented an excellent performance for universal diagnosis of T. cruzi infection (AUC = 1.0, Se and Sp = 100%). The combined set of attributes “α-TcI-TRYPO/1:4,000, cut-off/PPFP = 50%”, “α-TcII-AMA/1:1,000, cut-off/PPFP = 40%” and “α-TcVI-EPI/1:1,000, cut-off/PPFP = 45%” showed good performance to segregate infections with TcI/Colombiana, TcVI/CL or TcII/Y strain. Overall, hosts infected with TcI/Colombiana and TcII/Y strains displayed opposite patterns of reactivity with “α-TcI TRYPO” and “α-TcII AMA”. Hosts infected with TcVI/CL strain showed a typical interweaved distribution pattern. The method presented a good performance for genotype-specific diagnosis, with global accuracy of 69% when the population/prototype scenario include TcI, TcVI and TcII infections and 94% when comprise only TcI and TcII infections. This study also proposes a receiver operating reactivity panel, providing a feasible tool to classify serum samples from hosts infected with distinct T. cruzi genotypes, supporting the potential of this method for universal and genotype

  14. Single-scan dual-tracer FLT+FDG PET tumor characterization.

    PubMed

    Kadrmas, Dan J; Rust, Thomas C; Hoffman, John M

    2013-02-07

    Rapid multi-tracer PET aims to image two or more tracers in a single scan, simultaneously characterizing multiple aspects of physiology and function without the need for repeat imaging visits. Using dynamic imaging with staggered injections, constraints on the kinetic behavior of each tracer are applied to recover individual-tracer measures from the multi-tracer PET signal. The ability to rapidly and reliably image both (18)F-fluorodeoxyglucose (FDG) and (18)F-fluorothymidine (FLT) would provide complementary measures of tumor metabolism and proliferative activity, with important applications in guiding oncologic treatment decisions and assessing response. However, this tracer combination presents one of the most challenging dual-tracer signal-separation problems--both tracers have the same radioactive half-life, and the injection delay is short relative to the half-life and tracer kinetics. This work investigates techniques for single-scan dual-tracer FLT+FDG PET tumor imaging, characterizing the performance of recovering static and dynamic imaging measures for each tracer from dual-tracer datasets. Simulation studies were performed to characterize dual-tracer signal-separation performance for imaging protocols with both injection orders and injection delays of 10-60 min. Better performance was observed when FLT was administered first, and longer delays before administration of FDG provided more robust signal-separation and recovery of the single-tracer imaging measures. An injection delay of 30 min led to good recovery (R > 0.96) of static image values (e.g. SUV), K(net), and K(1) as compared to values from separate, single-tracer time-activity curves. Recovery of higher order rate parameters (k(2), k(3)) was less robust, indicating that information regarding these parameters was harder to recover in the presence of statistical noise and dual-tracer effects. Performance of the dual-tracer FLT(0 min)+FDG(32 min) technique was further evaluated using PET/CT imaging

  15. Single-scan dual-tracer FLT+FDG PET tumor characterization

    NASA Astrophysics Data System (ADS)

    Kadrmas, Dan J.; Rust, Thomas C.; Hoffman, John M.

    2013-02-01

    Rapid multi-tracer PET aims to image two or more tracers in a single scan, simultaneously characterizing multiple aspects of physiology and function without the need for repeat imaging visits. Using dynamic imaging with staggered injections, constraints on the kinetic behavior of each tracer are applied to recover individual-tracer measures from the multi-tracer PET signal. The ability to rapidly and reliably image both 18F-fluorodeoxyglucose (FDG) and 18F-fluorothymidine (FLT) would provide complementary measures of tumor metabolism and proliferative activity, with important applications in guiding oncologic treatment decisions and assessing response. However, this tracer combination presents one of the most challenging dual-tracer signal-separation problems—both tracers have the same radioactive half-life, and the injection delay is short relative to the half-life and tracer kinetics. This work investigates techniques for single-scan dual-tracer FLT+FDG PET tumor imaging, characterizing the performance of recovering static and dynamic imaging measures for each tracer from dual-tracer datasets. Simulation studies were performed to characterize dual-tracer signal-separation performance for imaging protocols with both injection orders and injection delays of 10-60 min. Better performance was observed when FLT was administered first, and longer delays before administration of FDG provided more robust signal-separation and recovery of the single-tracer imaging measures. An injection delay of 30 min led to good recovery (R > 0.96) of static image values (e.g. SUV), Knet, and K1 as compared to values from separate, single-tracer time-activity curves. Recovery of higher order rate parameters (k2, k3) was less robust, indicating that information regarding these parameters was harder to recover in the presence of statistical noise and dual-tracer effects. Performance of the dual-tracer FLT(0 min)+FDG(32 min) technique was further evaluated using PET/CT imaging studies in

  16. Single-scan dual-tracer FLT+FDG PET tumor characterization

    PubMed Central

    Kadrmas, Dan J; Rust, Thomas C; Hoffman, John M

    2013-01-01

    Rapid multi-tracer PET aims to image two or more tracers in a single scan, simultaneously characterizing multiple aspects of physiology and function without the need for repeat imaging visits. Using dynamic imaging with staggered injections, constraints on the kinetic behavior of each tracer are applied to recover individual-tracer measures from the multi-tracer PET signal. The ability to rapidly and reliably image both 18F-fluorodeoxyglucose (FDG) and 18F-fluorothymidine (FLT) would provide complementary measures of tumor metabolism and proliferative activity, with important applications in guiding oncologic treatment decisions and assessing response. However, this tracer combination presents one of the most challenging dual-tracer signal-separation problems—both tracers have the same radioactive half-life, and the injection delay is short relative to the half-life and tracer kinetics. This work investigates techniques for single-scan dual-tracer FLT+FDG PET tumor imaging, characterizing the performance of recovering static and dynamic imaging measures for each tracer from dual-tracer datasets. Simulation studies were performed to characterize dual-tracer signal-separation performance for imaging protocols with both injection orders and injection delays of 10–60 min. Better performance was observed when FLT was administered first, and longer delays before administration of FDG provided more robust signal-separation and recovery of the single-tracer imaging measures. An injection delay of 30 min led to good recovery (R > 0.96) of static image values (e.g. SUV), Knet, and K1 as compared to values from separate, single-tracer time-activity curves. Recovery of higher order rate parameters (k2, k3) was less robust, indicating that information regarding these parameters was harder to recover in the presence of statistical noise and dual-tracer effects. Performance of the dual-tracer FLT(0 min)+FDG(32 min) technique was further evaluated using PET/CT imaging studies

  17. Synthesis, Characterization, and Preclinical Evaluation of (99m)Tc-Labeled Macrobicyclic and Tricyclic Chelators as Single Photon Emission Computed Tomography Tracer.

    PubMed

    Yadav, Neelam; Chuttani, Krishna; Mishra, Anil K; Singh, Bachcha

    2016-05-01

    The novel tetraaza macrobicyclic chelator 3,6,9,15-tetraazabicyclo[9.3.1]pentadeca-1(15),11,13-triene-2,10-dione (TBPD) and pentaaza macrotricyclic chelator 9-oxa-3,6,12,15,21-pentaazatricyclo[15,3,2,1]trieicos-1(21),17,19-triene-2,7,11,16-tetradione (OPTT) were synthesized, characterized, and radiolabeled with (99m)Tc to produce (99m)Tc-TBPD and (99m)Tc-OPTT. These radiolabeled complexes were prepared with high radiolabeling yield, radiochemical purity, and good in vitro stability up to 24 h. The labeling efficiency of (99m)Tc-TBPD and (99m)Tc-OPTT was found 98% and 97%. In vitro serum stability of (99m)Tc-TBPD was found to be 95.2%, while that of (99m)Tc-OPTT 94.2% up to 24 h. Blood kinetics experiments of (99m)Tc-labeled complexes showed biphasic pattern of blood clearance. About 99.57 ± 0.89% activity of (99m)Tc-TBPD and 99.42 ± 0.88% activity of (9m)Tc-OPTT were cleared off blood stream at 24 h postadministration. The biological half-life of (99m) Tc-TBPD was observed: t1/2(F) 1 h 5 min and t1/2(S) 12 h and biological half-life of (99m)Tc-OPTT was observed: t1/2(F) 1 h 10 min and t1/2(S) 9 h 50 min, respectively. The biodistribution studies revealed that maximum uptake of (99m)Tc-TBPD was found in liver, concluded that excretory pathway is hepatobiliary, while that of (99m)Tc-OPTT was renal as well as hepatobiliary. The negligible activity observed in stomach confirming the stability of radiolabeled complex in biological milieu. In vitro cytotoxicity study of TBPD and OPTT did not show any considerable antiproliferative activity against cancer cells of human cervical SW756, HeLa, and glioblastoma U-87, U373 cell lines. © 2015 John Wiley & Sons A/S.

  18. 99mTc-3P4-RGD2 Scintimammography in the Assessment of Breast Lesions: Comparative Study with 99mTc-MIBI

    PubMed Central

    Gao, Shi; Ji, Tiefeng; Wen, Qiang; Song, Yan; Zhu, Lei; Xu, Zheli; Liu, Lin

    2014-01-01

    Purpose To compare the potential application of 99mTc-3P-Arg-Gly-Asp (99mTc-3P4-RGD2) scintimammography (SMM) and 99mTc-methoxyisobutylisonitrile (99mTc-MIBI) SMM for the differentiation of malignant from benign breast lesions. Method Thirty-six patients with breast masses on physical examination and/or suspicious mammography results that required fine needle aspiration cytology biopsy (FNAB) were included in the study. 99mTc-3P4-RGD2 and 99mTc-MIBI SMM were performed with single photon emission computed tomography (SPECT) at 60 min and 20 min respectively after intravenous injection of 738±86 MBq radiotracers on a separate day. Images were evaluated by the tumor to non-tumor localization ratios (T/NT). Receiver operating characteristic (ROC) curve analysis was performed on each radiotracer to calculate the cut-off values of quantitative indices and to compare the diagnostic performance for the ability to differentiate malignant from benign diseases. Results The mean T/NT ratio of 99mTc-3P4-RGD2 in malignant lesions was significantly higher than that in benign lesions (3.54±1.51 vs. 1.83±0.98, p<0.001). The sensitivity, specificity, and accuracy of 99mTc-3P4-RGD2 SMM were 89.3%, 90.9% and 89.7%, respectively, with a T/NT cut-off value of 2.40. The mean T/NT ratio of 99mTc-MIBI in malignant lesions was also significantly higher than that in benign lesions (2.86±0.99 vs. 1.51±0.61, p<0.001). The sensitivity, specificity and accuracy of 99mTc-MIBI SMM were 87.5%, 72.7% and 82.1%, respectively, with a T/NT cut-off value of 1.45. According to the ROC analysis, the area under the curve for 99mTc-3P4-RGD2 SMM (area = 0.851) was higher than that for 99mTc-MIBI SMM (area = 0.781), but the statistical difference was not significant. Conclusion 99mTc-3P4-RGD2 SMM does not provide any significant advantage over the established 99mTc-MIBI SMM for the detection of primary breast cancer. The T/NT ratio of 99mTc-3P4-RGD2 SMM was significantly higher than that of 99mTc

  19. Contour advection with surgery: A technique for investigating finescale structure in tracer transport

    NASA Technical Reports Server (NTRS)

    Waugh, Darryn W.; Plumb, R. Alan

    1994-01-01

    We present a trajectory technique, contour advection with surgery (CAS), for tracing the evolution of material contours in a specified (including observed) evolving flow. CAS uses the algorithms developed by Dritschel for contour dynamics/surgery to trace the evolution of specified contours. The contours are represented by a series of particles, which are advected by a specified, gridded, wind distribution. The resolution of the contours is preserved by continually adjusting the number of particles, and finescale features are produced that are not present in the input data (and cannot easily be generated using standard trajectory techniques). The reliability, and dependence on the spatial and temporal resolution of the wind field, of the CAS procedure is examined by comparisons with high-resolution numerical data (from contour dynamics calculations and from a general circulation model), and with routine stratospheric analyses. These comparisons show that the large-scale motions dominate the deformation field and that CAS can accurately reproduce small scales from low-resolution wind fields. The CAS technique therefore enables examination of atmospheric tracer transport at previously unattainable resolution.

  20. Comparative analysis of 99mTc-depreotide and 99mTc-EDDA/HYNIC-TOC thorax scintigrams acquired for the purpose of differential diagnosis of solitary pulmonary nodules.

    PubMed

    Płachcińska, Anna; Mikołajczak, Renata; Kozak, Józef; Rzeszutek, Katarzyna; Kuśmierek, Jacek

    2006-01-01

    Aiming at comparison of diagnostic efficacy of 2 radiopharmaceuticals: 99mTc-depreotide (Neospect, Amersham) and 99mTc-EDDA/HYNIC-Tyr3-octreotide (Tektrotyd, Polatom), in differentiation between malignant and benign etiology of solitary pulmonary nodules (SPNs), radionuclide studies with 2 radiotracers were performed in 18 patients. For both radiopharmaceuticals the same acquisition and processing protocols were applied. Studies were acquired with SPECT technique, after administration of 740 MBq of activity. Scintigrams were assessed visually, as: positive (+), equivocal (+/-) and negative (-). Additionally, uptake intensity of both radiotracers in nodules was assessed semiquantitatively, using a tumour-to-background ratio. Verification of scintigraphic results was based in 14 cases upon a pathological examination of tumour samples (histopathology) and in the remaining 4 - on clinical observation and bacteriological studies. Normal scintigrams obtained with both radiopharmaceuticals differed significantly. 99mTc-depreotide was markedly accumulated in spine, sternum, ribs and lungs (mean lung/heart ratio = 2.2). This accumulation was not observed on 99mTc- -EDDA/HYNIC-TOC scintigrams (mean lung/heart ratio = 0.7). In 6 patients a malignant etiology--lung cancer--was revealed (5--adenocarcinoma, 1--squamous cell) and the other 12 cases turned out to be benign (4 hamartomas, 3 tuberculomas, a tuberculous infiltrate, an alien body with inflammatory reaction, a hyperplasia of lymphatic tissue and 2 cases of unknown etiology, from which one had a stable size and the other resolved during a 6 month observation period). In all 6 cases of lung cancer positive results were obtained with both tracers. Moreover, in 2 patients metastases in mediastinum could be observed on scintigrams obtained with both radiopharmaceuticals. From among 12 cases of benign etiology 6 99mTc-depreotide scintigrams were true negative, 1--equivocal and 5--false positive, whereas 6 99mTc

  1. 99mTc-N4-[Tyr3]Octreotate Versus 99mTc-EDDA/HYNIC-[Tyr3]Octreotide: an intrapatient comparison of two novel Technetium-99m labeled tracers for somatostatin receptor scintigraphy.

    PubMed

    Gabriel, Michael; Decristoforo, Clemens; Maina, Theodosia; Nock, Berthold; vonGuggenberg, Elisabeth; Cordopatis, Paul; Moncayo, Roy

    2004-02-01

    Tetraamine-[Tyr3]octreotate (Demotate) is a somatostatin (SST) analogue that can be easily labeled with 99mTc at high specific activities and showed promising preclinical properties for SST receptor scintigraphy. This study reports on the first intra-patient comparison of 99mTc-Demotate and another 99mTc-labeled SST analogue, 99mTc-EDDA/HYNIC-TOC (HYNIC-TOC). Five patients with carcinoid tumors (n = 2) and endocrine pancreatic tumors (n = 3) were investigated with both radiopharmaceuticals. 99mTc-Demotate rapidly visualized somatostatin receptor positive tumors as early as 15 minutes post-injection (p.i.) with maximum tumor uptake and tumor/organ ratios already 1 hour p.i. Organs of predominant physiological uptake were the spleen and the kidneys with no intestinal excretion detectable up to 24 hours. 99mTc-Demotate exhibited faster pharmacokinetic properties compared to HYNIC-TOC. Tumor/organ ratios at equivalent time points were higher or comparable for 99mTc-Demotate in three patients with a matching scan result. Equivocal findings were observed in two patients, i.e. comparable uptake behavior in larger lesions with differences in smaller ones. 99mTc-Demotate is a promising agent for somatostatin receptor scintigraphy providing images of excellent quality as early as 1 hour after injection.

  2. Imaging experimental intraabdominal abscesses with 99mTc-PEG liposomes and 99mTc-HYNIC IgG.

    PubMed Central

    Dams, E T; Reijnen, M M; Oyen, W J; Boerman, O C; Laverman, P; Storm, G; van der Meer, J W; Corstens, F H; van Goor, H

    1999-01-01

    OBJECTIVE: To evaluate the accuracy of technetium-99m-labeled polyethylene glycol-coated liposomes (99mTc-PEG liposomes) and technetium-99m-labeled nonspecific human immunoglobulin G (99mTc-HYNIC IgG) for the scintigraphic detection of experimental intraabdominal abscesses in comparison with that of a standard agent, gallium-67 citrate. BACKGROUND: Scintigraphic imaging techniques can be very useful for the rapid and accurate localization of intraabdominal abscesses. Two newly developed radiolabeled agents, 99mTc-PEG liposomes and 99mTc-HYNIC IgG, have shown to be excellent agents for imaging experimental focal infection, but have not yet been studied in the detection of abdominal abscesses. METHODS: Intraabdominal abscesses were induced in 42 rats using the cecal ligation and puncture technique. Seven days later, randomized groups of rats received 99mTc-PEG liposomes, 99mTc-HYNIC IgG, or 67Ga citrate intravenously. The rats were imaged up to 24 hours after the injection. The biodistribution of the radiolabel was determined by counting dissected tissues ex vivo. Macroscopic intraabdominal abnormalities and focal uptake on the images were independently scored on a semiquantitative scale. RESULTS: 99mTc-PEG liposomes provided the earliest scintigraphic visualization of the abscess (as soon as 2 hours after the injection vs. 4 hours for the other two agents). Liposomes, IgG, and gallium all showed similarly high absolute uptake in the abscess. Focal uptake of liposomes and gallium correlated best with the extent of the macroscopic abnormalities. CONCLUSIONS: 99mTc-PEG liposomes and 99mTc-HYNIC IgG performed at least as well as the standard agent, 67Ga citrate, in the detection of experimental intraabdominal abscesses, with obvious advantages such as lower radiation exposure and more favorable physical properties. Of the two technetium agents, the liposomes seemed to be superior, providing the earliest diagnostic image and the best correlation with the inflammatory

  3. Ibogaine labeling with 99mTc-tricarbonyl: synthesis and transport at the mouse blood-brain barrier.

    PubMed

    Tournier, Nicolas; André, Pascal; Blondeel, Sandy; Rizzo-Padoin, Nathalie; du Moulinet d'Hardemarre, Amaury; Declèves, Xavier; Scherrmann, Jean-Michel; Cisternino, Salvatore

    2009-12-01

    The (99m)Tc-tricarbonyl core may be used as an ideal tool for gamma-labeling ligands in noninvasive SPECT imaging. However, most (99m)Tc-tricarbonyl-labeled agents have difficulty crossing the blood-brain barrier (BBB). We radiolabeled the neuroactive indole ibogaine with (99m)Tc-tricarbonyl and measured its transport into the mouse brain by in situ brain perfusion. We measured the interactions of [(99m)Tc(CO)(3)-ibogaine](+) and (99m)Tc-tricarbonyl with the main BBB efflux transporters P-gp and BCRP in vitro and in vivo. Ibogaine was radiolabeled (yield: over 95%). [(99m)Tc(CO)(3)-ibogaine](+) entered the brain (K(in)) poorly (0.18 microL/g/s), at about the same rate as (99m)Tc-tricarbonyl (0.16 microL/g/s) and [(99m)Tc-sestamibi](+) (0.10 microL/g/s). The CNS tracer [(99m)Tc-HMPAO](0) entered the brain approximately 70-times higher than [(99m)Tc(CO)(3)-ibogaine](+). In vitro studies revealed that neither [(99m)Tc(CO)(3)-ibogaine](+) nor (99m)Tc-tricarbonyl ion were substrates for P-gp or BCRP. But lowering the membrane dipole potential barrier with phloretin enhanced the brain transport of [(99m)Tc(OH(2))(3)(CO)(3)](+) approximately 3-fold. Thus, ibogaine directly labeled with (99m)Tc-tricarbonyl is not suitable for CNS imaging because of its poor uptake. Brain transport is not restricted by efflux transporters but is reduced by its lipophilicity and interaction with the membrane-positive dipole potential. 2009 Wiley-Liss, Inc. and the American Pharmacists Association

  4. The fluorescent tracer experiment on Holiday Beach near Mugu Canyon, Southern California

    USGS Publications Warehouse

    Kinsman, Nicole; Xu, J. P.

    2012-01-01

    After revisiting sand tracer techniques originally developed in the 1960s, a range of fluorescent coating formulations were tested in the laboratory. Explicit steps are presented for the preparation of the formulation evaluated to have superior attributes, a thermoplastic pigment/dye in a colloidal mixture with a vinyl chloride/vinyl acetate copolymer. In September 2010, 0.59 cubic meters of fluorescent tracer material was injected into the littoral zone about 4 kilometers upcoast of Mugu submarine canyon in California. The movement of tracer was monitored in three dimensions over the course of 4 days using manual and automated techniques. Detailed observations of the tracer's behavior in the coastal zone indicate that this tracer successfully mimicked the native beach sand and similar methods could be used to validate models of tracer movement in this type of environment. Recommendations including how to time successful tracer studies and how to scale the field of view of automated camera systems are presented along with the advantages and disadvantages of the described tracer methodology.

  5. Radionuclide imaging of myocardial infarction using Tc-99m TBI

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holman, B.L.; Campbell, S.; Kirshenbaum, J.M.

    The cationic complex Tc-99m t-butylisonitrile (TBI) concentrates in the myocardial tissue of several animal species. Its myocardial distribution is proportional to blood flow both in zones of ischemia and in normal myocardium at rest. Planar, tomographic, and gated myocardial images have been obtained using Tc-99m TBI in the human. The authors investigated the potential application of Tc-99m TBI imaging to detect and localize myocardial infarction. Four subjects without clinical evidence of cardiovascular disease and five patients with ECG evidence of previous myocardial infarction were studied. Tc-99m TBI (10mCi) was injected intravenously with the patient in a resting state with planarmore » imaging in the anterior, 30 and 70 degree LAO projections beginning one hr after injection. The distribution of the tracer was homogeneous throughout the left ventricular wall in the normal subjects. Regional perfusion defects were present in 4/5 of the patients with myocardial infarction. Location of the defects corresponded to the location of the infarct using ECG criteria (2 inferoposterior and 2 anterior). The patient in whom the Tc-99m TBI image appeared normal had sustained a subendocardial myocardial infarct which could not be localized by ECG; the other 4 pts had transmural infarcts. Anterior and 30 degree LAO images were of excellent quality in all cases; there was overlap of the liver on the inferior wall of the left ventricle on the 70 degree LAO views. The authors conclude that accurate perfusion imaging may be possible using Tc-99m TBI in patients with transmural myocardial infarction.« less

  6. Is prophylactic embolization of the hepatic falciform artery needed before radioembolization in patients with 99mTc-MAA accumulation in the anterior abdominal wall?

    PubMed

    Ahmadzadehfar, Hojjat; Möhlenbruch, Markus; Sabet, Amir; Meyer, Carsten; Muckle, Marianne; Haslerud, Torjan; Wilhelm, Kai; Schild, Hans Heinz; Biersack, Hans Jürgen; Ezziddin, Samer

    2011-08-01

    While influx of chemoembolic agents into the hepatic falciform artery (HFA) from the hepatic artery can cause supraumbilical skin rash, epigastric pain and even skin necrosis, the significance of a patent HFA in patients undergoing radioembolization is not completely clear. Furthermore, the presence of tracer in the anterior abdominal wall seen in (99m)Tc-macroaggregated albumin ((99m)Tc-MAA) images, which is generally performed prior to radioembolization, has been described as a sign of a patent HFA. The aim of this retrospective study was to evaluate the incidence and consequences of (99m)Tc-MAA accumulation in the anterior abdominal wall, indicating a patent HFA, in patients undergoing radioembolization of liver tumours. A total of 224 diagnostic hepatic angiograms combined with (99m)Tc-MAA SPECT/CT were acquired in 192 patients with different types of cancer, of whom 142 were treated with a total of 214 radioembolization procedures. All patients received a whole-body scan, and planar and SPECT/CT scans of the abdomen. Only patients with extrahepatic (99m)Tc-MAA accumulation in the anterior abdominal wall were included in this study. Posttreatment bremsstrahlung SPECT/CT and follow-up results for at least 3 months served as reference standards. Tracer accumulation in the anterior abdominal wall was present in pretreatment (99m)Tc-MAA SPECT/CT images of 18 patients (9.3%). The HFA was found and embolized by radiologists before treatment in one patient. In the remaining patients radioembolization was performed without any modification in the treatment plan despite the previously mentioned extrahepatic accumulation. Only one patient experienced abdominal muscle pain above the navel, which started 24 h after treatment and lasted for 48 h without any skin changes. The remaining patients did not experience any relevant side effects during the follow-up period. Side effects after radioembolization in patients with tracer accumulation in the anterior abdominal

  7. Radio-tracer techniques for the study of flow in saturated porous materials

    USGS Publications Warehouse

    Skibitzke, H.E.; Chapman, H.T.; Robinson, G.M.; McCullough, Richard A.

    1961-01-01

    An experiment was conducted by the U.S. Geological Survey to determine the feasibility of using a radioactive substance as a tracer in the study of microscopic flow in a saturated porous solid. A radioactive tracer was chosen in preference to dye or other chemical in order to eliminate effects of the tracer itself on the flow system such as those relating to density, viscosity and surface tension. The porous solid was artificial "sandstone" composed of uniform fine grains of sand bonded together with an epoxy adhesive. The sides of the block thus made were sealed with an epoxy coating compound to insure water-tightness. Because of the chemical inertness of the block it was possible to use radioactive phosphorus (P32). Ion-exchange equilibrium was created between the block and nonradioactive phosphoric acid. Then a tracer tagged with P32 was injected into the block in the desired geometric configuration, in this case, a line source. After equilibrium in isotopic exchange was reached between the block and the line source, the block was rinsed, drained and sawn into slices. It was found that a quantitative analysis of the flow system may be made by assaying the dissected block. ?? 1961.

  8. Long-term study of 99Tc in the marine environment on the Swedish west coast.

    PubMed

    Lindahl, P; Ellmark, C; Gäfvert, T; Mattsson, S; Roos, P; Holm, E; Erlandsson, B

    2003-01-01

    The activity concentration of (99)Tc in brown seaweed (Fucus vesiculosus and Fucus serratus) and seawater were analysed in samples collected in 1991, 1995 and 2001 at several stations along the Swedish west coast. In addition to these locations, a well-defined site (Särdal, 56.76 degrees N, 12.63 degrees E) was included with (99)Tc activity concentration data in seaweed from 1967 to 2000. Over the years, the major source of (99)Tc in the coastal waters of western Sweden has been the radioactive liquid discharge from the nuclear fuel reprocessing plant in Sellafield (UK) transported via ocean currents in the North Sea. The (99)Tc activity concentration in seaweed at the Särdal site increased from approximately 30 Bq kg(-1) up to 230 Bq kg(-1) (dry weight) between 1997 and 2000 due to the Sellafield EARP (Enhanced Actinide Removal Plant) discharges in 1995-1996, yielding an approximate transport time of 4-5 years between the Irish Sea and the Kattegat. Due to the very sharp gradient in (99)Tc concentration between the Baltic Sea and the North Sea, (99)Tc is presently one of the best transit tracers for the recent ventilation events in the Baltic Sea.

  9. A validation of the application of D2O stable isotope tracer techniques for monitoring day-to-day changes in muscle protein subfraction synthesis in humans

    PubMed Central

    Wilkinson, Daniel J.; Franchi, Martino V.; Brook, Matthew S.; Narici, Marco V.; Williams, John P.; Mitchell, William K.; Szewczyk, Nathaniel J.; Greenhaff, Paul L.; Atherton, Philip J.

    2013-01-01

    Quantification of muscle protein synthesis (MPS) remains a cornerstone for understanding the control of muscle mass. Traditional [13C]amino acid tracer methodologies necessitate sustained bed rest and intravenous cannulation(s), restricting studies to ∼12 h, and thus cannot holistically inform on diurnal MPS. This limits insight into the regulation of habitual muscle metabolism in health, aging, and disease while querying the utility of tracer techniques to predict the long-term efficacy of anabolic/anticatabolic interventions. We tested the efficacy of the D2O tracer for quantifying MPS over a period not feasible with 13C tracers and too short to quantify changes in mass. Eight men (22 ± 3.5 yr) undertook one-legged resistance exercise over an 8-day period (4 × 8–10 repetitions, 80% 1RM every 2nd day, to yield “nonexercised” vs. “exercise” leg comparisons), with vastus lateralis biopsies taken bilaterally at 0, 2, 4, and 8 days. After day 0 biopsies, participants consumed a D2O bolus (150 ml, 70 atom%); saliva was collected daily. Fractional synthetic rates (FSRs) of myofibrillar (MyoPS), sarcoplasmic (SPS), and collagen (CPS) protein fractions were measured by GC-pyrolysis-IRMS and TC/EA-IRMS. Body water initially enriched at 0.16–0.24 APE decayed at ∼0.009%/day. In the nonexercised leg, MyoPS was 1.45 ± 0.10, 1.47 ± 0.06, and 1.35 ± 0.07%/day at 0–2, 0–4, and 0–8 days, respectively (∼0.05–0.06%/h). MyoPS was greater in the exercised leg (0–2 days: 1.97 ± 0.13%/day; 0–4 days: 1.96 ± 0.15%/day, P < 0.01; 0–8 days: 1.79 ± 0.12%/day, P < 0.05). CPS was slower than MyoPS but followed a similar pattern, with the exercised leg tending to yield greater FSRs (0–2 days: 1.14 ± 0.13 vs. 1.45 ± 0.15%/day; 0–4 days: 1.13 ± 0.07%/day vs. 1.47 ± 0.18%/day; 0–8 days: 1.03 ± 0.09%/day vs. 1.40 ± 0.11%/day). SPS remained unchanged. Therefore, D2O has unrivaled utility to quantify day-to-day MPS in humans and inform on short

  10. Convective Distribution of Tropospheric Ozone and Tracers in the Central American ITCZ Region: Evidence from Observations During TC4

    NASA Technical Reports Server (NTRS)

    Avery, Melody; Twohy, Cynthia; MCabe, David; Joiner, Joanna; Severance, Kurt; Atlas, Eliot; Blake, Donald; Bui, T. P.; Crounse, John; Dibb, Jack; hide

    2010-01-01

    During the Tropical Composition, Clouds and Climate Coupling (TC4) experiment that occurred in July and August of 2007, extensive sampling of active convection in the ITCZ region near Central America was performed from multiple aircraft and satellite sensors. As part of a sampling strategy designed to study cloud processes, the NASA ER-2, WB-57 and DC-8 flew in stacked "racetrack patterns" in convective cells. On July 24, 2007, the ER-2 and DC-8 probed an actively developing storm and the DC-8 was hit by lightning. Case studies of this flight, and of convective outflow on August 5, 2007 reveal a significant anti-correlation between ozone and condensed cloud water content. With little variability in the boundary layer and a vertical gradient, low ozone in the upper troposphere indicates convective transport. Because of the large spatial and temporal variability in surface CO and other pollutants in this region, low ozone is a better convective indicator. Lower tropospheric tracers methyl hydrogen peroxide, total organic bromine and calcium substantiate the ozone results. OMI measurements of mean upper tropospheric ozone near convection show lower ozone in convective outflow. A mass balance estimation of the amount of convective turnover below the tropical tropopause transition layer (TTL) is 50%, with an altitude of maximum convective outflow located between 10 and 11 km, 4 km below the cirrus anvil tops. It appears that convective lofting in this region of the ITCZ is either a two-stage or a rapid mixing process, because undiluted boundary layer air is never sampled in the convective outflow.

  11. TC-325 versus the conventional combined technique for endoscopic treatment of peptic ulcers with high-risk bleeding stigmata: A randomized pilot study.

    PubMed

    Kwek, Boon Eu Andrew; Ang, Tiing Leong; Ong, Peng Lan Jeannie; Tan, Yi Lyn Jessica; Ang, Shih Wen Daphne; Law, Ngai Moh; Thurairajah, Prem Harichander; Fock, Kwong Ming

    2017-06-01

    Preliminary studies on a new topical hemostatic agent, TC-325, have shown its safety and effectiveness in treating active upper gastrointestinal (GI) bleeding. However, to date there have been no randomized trials comparing TC-325 with the conventional combined technique (CCT). Our pilot study aimed to compare the efficacy and safety of TC-325 with those of CCT in treating peptic ulcers with active bleeding or high-risk stigmata. This was a comparative randomized study of patients with upper GI bleeding who had Forrest class I, IIA or IIB ulcers. Altogether 20 patients with a mean age of 70 years (range 23-87 years) were recruited, including 16 men, with a mean hemoglobin of 97 g/L. Initial hemostasis was successful in 19 (95.0%) patients, including 90.0% (9/10) in the TC-325 group and 100% (10/10) in the CCT group. TC-325 monotherapy failed to stop bleeding in a patient with Forrest IB posterior duodenal wall ulcer. Rebleeding was seen in 33.3% (3/9) of the patients in the TC-325 group and 10.0% (1/10) in the CCT group. One patient required angio-embolization therapy while three had successful conventional endotherapy. Two patients from the TC-325 group had serious adverse events that were not procedure- or therapy-related. In patients with Forrest IIA or IIB ulcers, five received TC-325 monotherapy; none had rebleeding. Our pilot study showed that TC-325 has a tendency towards a higher rebleeding rate than CCT, when treating actively bleeding ulcers. Larger trials are necessary for definitive results. © 2017 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and John Wiley & Sons Australia, Ltd.

  12. Tracer-monitored flow titrations.

    PubMed

    Sasaki, Milton K; Rocha, Diogo L; Rocha, Fábio R P; Zagatto, Elias A G

    2016-01-01

    The feasibility of implementing tracer-monitored titrations in a flow system is demonstrated. A dye tracer is used to estimate the instant sample and titrant volumetric fractions without the need for volume, mass or peak width measurements. The approach was applied to spectrophotometric flow titrations involving variations of sample and titrant flow-rates (i.e. triangle programmed technique) or concentration gradients established along the sample zone (i.e. flow injection system). Both strategies required simultaneous monitoring of two absorbing species, namely the titration indicator and the dye tracer. Mixing conditions were improved by placing a chamber with mechanical stirring in the analytical path aiming at to minimize diffusional effects. Unlike most of flow-based titrations, the innovation is considered as a true titration, as it does not require a calibration curve thus complying with IUPAC definition. As an application, acidity evaluation in vinegars involving titration with sodium hydroxide was selected. Phenolphthalein and brilliant blue FCF were used as indicator and dye tracer, respectively. Effects of sample volume, titrand/titrant concentrations and flow rates were investigated aiming at improved accuracy and precision. Results were reliable and in agreement with those obtained by a reference titration procedure. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Radio-guided surgery with the use of [99mTc-EDDA/HYNIC]octreotate in intra-operative detection of neuroendocrine tumours of the gastrointestinal tract.

    PubMed

    Hubalewska-Dydejczyk, A; Kulig, J; Szybinski, P; Mikolajczak, R; Pach, D; Sowa-Staszczak, A; Fröss-Baron, K; Huszno, B

    2007-10-01

    Radio-guided surgery (RGS) is an intra-operative localising technique which enables identification of tissue "marked" by a specific radiotracer injected before surgery. It is mainly used for sentinel node mapping and for detection of parathyroid adenomas and other tumours, including neuroendocrine tumours of the gastrointestinal tract (GEP-NET). The aim of this study was to determine whether intra-operative radio-detection with the use of [(99m)Tc-EDDA/HYNIC]octreotate, a new somatostatin analogue, is able to reveal an unknown primary and secondary sites, thereby improving surgical treatment and the final outcome of GEP-NET. The study group included nine patients with suspected GEP-NET (four carcinoids, five pancreatic NET) localised with somatostatin receptor scintigraphy (with [(99m)Tc-EDDA/HYNIC]octreotate), who had negative results on other pre-operative imaging tests. At surgery, suspected tumours were measured in situ and ex vivo and precise exploration of the abdominal cavity was performed with the intra-operative scintillation detector (Navigator). Intra-operative gamma counting localised three carcinoids. In one patient SRS was false positive (owing to inflammatory infiltration). Compared with SRS, RGS revealed additional lymph node metastases in one case. RGS resulted in successful localisation of all pancreatic NET (the smallest lesion was 8 mm in diameter). [(99m)Tc-EDDA/HYNIC]octreotate SRS followed by RGS is a promising technique to improve the rate of detection and efficacy of treatment of GEP-NET, especially in the presence of occult endocrine tumours. The imaging properties of [(99m)Tc-EDDA/HYNIC]octreotate and the 1-day imaging protocol offer opportunities for more widespread application of this tracer followed by RGS in oncology.

  14. Diagnostic accuracy of [99mTc]Tc-Sestamibi in the assessment of thyroid nodules.

    PubMed

    Yordanova, Anna; Mahjoob, Soha; Lingohr, Philipp; Kalff, Jörg; Türler, Andreas; Palmedo, Holger; Biersack, Hans-Jürgen; Kristiansen, Glen; Farahati, Jamshid; Essler, Markus; Ahmadzadehfar, Hojjat

    2017-11-07

    [ 99m Tc]Tc-Sestamibi (MIBI) is an increasingly used tool for evaluation of thyroid nodules. However, there is a lack of evidence about the accuracy of this method in the European population. The aim of this study was to assess the utility of MIBI for the differentiation of thyroid nodules in a large cohort. 161 patients underwent MIBI, followed by a thyroidectomy. We used a dual phase MIBI protocol. Interpretation of the images included a scoring system from 0 (absent) to 3 (increased); this was to provide a scale for the uptake of the thyroid nodule in comparison to the paranodular tissue. Additionally, we evaluated the tracer uptake trend in late images compared to early images. We used the final histopathology as the reference standard. Scores 0-1 in early images, scores 0-2 in late images, and an absence of increasing uptake in the thyroid nodule in late images, showed the best predictive values to exclude malignancy, respectively (negative predictive value (NPV) 89%). Highest sensitivity (91%) for malignant nodules was evident in early images with a score 1-3. Highest specificity (91%) was obtained when the negative was defined as an absence of uptake-increase, in the late images. This study confirms that the most valuable feature of MIBI is the high NPV. Thus, with the appropriate interpretation method, high sensitivity and specificity, and moderate PPV can be obtained.

  15. Radionuclide imaging of bone marrow disorders

    PubMed Central

    Agool, Ali; Glaudemans, Andor W. J. M.; Boersma, Hendrikus H.; Dierckx, Rudi A. J. O.; Vellenga, Edo

    2010-01-01

    Noninvasive imaging techniques have been used in the past for visualization the functional activity of the bone marrow compartment. Imaging with radiolabelled compounds may allow different bone marrow disorders to be distinguished. These imaging techniques, almost all of which use radionuclide-labelled tracers, such as 99mTc-nanocolloid, 99mTc-sulphur colloid, 111In-chloride, and radiolabelled white blood cells, have been used in nuclear medicine for several decades. With these techniques three separate compartments can be recognized including the reticuloendothelial system, the erythroid compartment and the myeloid compartment. Recent developments in research and the clinical use of PET tracers have made possible the analysis of additional properties such as cellular metabolism and proliferative activity, using 18F-FDG and 18F-FLT. These tracers may lead to better quantification and targeting of different cell systems in the bone marrow. In this review the imaging of different bone marrow targets with radionuclides including PET tracers in various bone marrow diseases are discussed. PMID:20625724

  16. Diffuse Thyroid Metastasis From Lung Cancer Mimicking Thyroiditis on 99mTc-Pertechnetate Scintigraphy.

    PubMed

    Gao, Rui; Gao, Shan; Feng, Jinteng; Wang, Yuanbo; Zhang, Guangjian

    2017-09-01

    Possible thyroiditis was suspected in a 56-year-old man who initially presented sore throat because laboratory examinations revealed decreased serum thyroid hormone and the Tc-pertechnetate scintigraphy showed no tracer uptake by the thyroid gland. However, subsequent examination demonstrated that the absence of pertechnetate activity in the thyroid was due to complete replacement of thyroid gland by the metastasis from lung adenocarcinoma, which was unknown at the initial presentation.

  17. Techniques for Connecting Superconducting Thin Films

    NASA Technical Reports Server (NTRS)

    Mester, John; Gwo, Dz-Hung

    2006-01-01

    Several improved techniques for connecting superconducting thin films on substrates have been developed. The techniques afford some versatility for tailoring the electronic and mechanical characteristics of junctions between superconductors in experimental electronic devices. The techniques are particularly useful for making superconducting or alternatively normally conductive junctions (e.g., Josephson junctions) between patterned superconducting thin films in order to exploit electron quantum-tunneling effects. The techniques are applicable to both low-Tc and high-Tc superconductors (where Tc represents the superconducting- transition temperature of a given material), offering different advantages for each. Most low-Tc superconductors are metallic, and heretofore, connections among them have been made by spot welding. Most high-Tc superconductors are nonmetallic and cannot be spot welded. These techniques offer alternatives to spot welding of most low-Tc superconductors and additional solutions to problems of connecting most high-Tc superconductors.

  18. Experiments to Evaluate and Implement Passive Tracer Gas Methods to Measure Ventilation Rates in Homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lunden, Melissa; Faulkner, David; Heredia, Elizabeth

    2012-10-01

    This report documents experiments performed in three homes to assess the methodology used to determine air exchange rates using passive tracer techniques. The experiments used four different tracer gases emitted simultaneously but implemented with different spatial coverage in the home. Two different tracer gas sampling methods were used. The results characterize the factors of the execution and analysis of the passive tracer technique that affect the uncertainty in the calculated air exchange rates. These factors include uncertainties in tracer gas emission rates, differences in measured concentrations for different tracer gases, temporal and spatial variability of the concentrations, the comparison betweenmore » different gas sampling methods, and the effect of different ventilation conditions.« less

  19. Technetium-99m galactosyl-neoglycoalbumin (Tc-NGA) liver imaging: Application in liver transplantation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woodle, E.S.; Ward, R.E.; Vera, D.R.

    1985-05-01

    Tc-NGA is a new liver imaging agent which binds to hepatic binding protein (HBP), a hepatocyte-specific membrane receptor. The purpose of the present study was to evaluate the potential role of Tc-NGA imaging in liver transplantation. The molar Tc-NGA dose was standardized according to patient weight (0.7 nmole/kg). After a 30 minute dynamic imaging study (5 mCi, IV), kinetic analysis of time activity data (heart, liver), provided values for receptor concentration, (HBP), and hepatic blood flow, Q. Eleven Tc-NGA imaging studies were performed in transplant candidates and 22 studies were performed in seven transplant recipients. Preservation damage was manifested bymore » diffuse patchiness in tracer distribution which resolved during the following two weeks. Histologically proven, localized hepatic infarcts were demonstrated in three recipients. Lobar infarction was demonstrated in one recipient. Hepatic regeneration was later demonstrated in this patient after hepatic lobectomy. Hepatic blood flow was markedly decreased in the early postoperative period, but improved with time. Increased (HBP) was demonstrated with regeneration. Markedly decreased (HBP) and Q were obtained in several candidates who died awaiting transplantation. These studies indicate that TC-NGA liver imaging provides a valuable new means for: (1) evaluation of preservation damage, (2) early demonstration of hepatic infarction, (3) evaluation of hepatic rejection, and (4) selection of patients for hepatic transplantation.« less

  20. 99mTc-MDM Brain SPECT for the Detection of Recurrent/Remnant Glioma-Comparison With ceMRI and 18F-FLT PET Imaging: Initial Results.

    PubMed

    Singh, Baljinder; Kumar, Narendra; Sharma, Sarika; Watts, Ankit; Hazari, Puja P; Rani, Nisha; Vyas, Sameer; Anish, Bhattacharya; Mishra, Anil K

    2015-10-01

    To evaluate the diagnostic use of an indigenously developed single vial ready to label (with Tc) kit preparation of bis-methionine-DTPA (Tc-MDM) for the detection of recurrent/residual glioma. We prospectively studied 32 patients (21 male and 11 female subjects aged 43.0±16.0 years) with clinical suspicion of postoperative recurrent/residual glioma. After radical radiotherapy (54.0-60.0 Gy) with or without concurrent temozolomide as indicated, Tc-MDM SPECT and ceMRI of the brain was performed in all the patients and F-FLT-PET imaging in 16 of 32 patients. MDM SPECT and ceMRI findings were concordant in 28 patients (15 positive and 13 negative). The findings were discordant in the remaining 5 patients, with positive ceMRI and negative MDM-SPECT in 2 patients and negative ceMRI and positive MDM-SPECT in 3 patients. Tc-MDM-SPECT, F-FLT PET, and ceMRI scan findings were positive in 9 of 16 and negative in 5 of 16 patients. In the remaining 2 of 16 patients, both F-FLT-PET and Tc-MDM-SPECT were positive, but ceMRI was negative. Sensitivity, specificity, PPV, NPV, and DA of Tc-MDM-SPECT for diagnosing recurrent/residual glioma were 88.24%, 81.25%, 83.3%, 86.7%, and 84.8%, respectively. The diagnostic accuracy of Tc-bis-methionine (MDM)-SPECT imaging was comparable with that of ceMRI and F-FLT-PET and may be useful in the management of glioma patients in the postsurgical follow-up period. This imaging technique may be of special interest in peripheral hospitals/developing countries lacking access to expensive PET/cyclotron technology. However, comparison with the existing "gold standard" PET tracers, especially with C-11-methionine-PET imaging and histopathological correlation, is warranted in a large cohort of glioma patients through multicentric studies.

  1. 99mTc-HYNIC-TOC imaging in the evaluation of pancreatic masses which are potential neuroendocrine tumors.

    PubMed

    Qiao, Zhen; Zhang, Jingjing; Jin, Xiaona; Huo, Li; Zhu, Zhaohui; Xing, Haiqun; Li, Fang

    2015-05-01

    The aim of this investigation was to determine the accuracy of the findings and the diagnoses of Tc-hydrazinonicotinyl-Tyr3-octreotide scan (Tc-HYNIC-TOC imaging) in patients with pancreatic masses which were potential neuroendocrine tumors. Records of total 20 patients with pancreatic masses were retrospectively reviewed. All of the patients had been revealed by abdominal contrast CT and possibility of neuroendocrine tumors could not be excluded by CT imaging before Tc-HYNIC-TOC imaging. Tc-HYNIC-TOC imaging was performed at 1 and 4 hours post-tracer injection, and SPECT/CT images of the abdomen were also acquired. The image findings were compared to final diagnoses which were made from pathological examination. Among all 20 pancreatic masses evaluated, there were 16 malignant lesions which included 1 ductal adenocarcinoma and 15 neuroendocrine tumors. Tc-HYNIC-TOC imaging identified 14 of 15 pancreatic neuroendocrine tumors and excluded 4 of 5 lesions which were not neuroendocrine tumors. The overall sensitivity, specificity, and accuracy was therefore 93.3% (14 of 15), 80% (4 of 5), and 90.0% (18 of 20), respectively, in our patient population. Tc-HYNIC-TOC imaging provides reasonable accuracy in the evaluation pancreatic mass suspected to be neuroendocrine tumors.

  2. Innovative techniques for the description of reservoir heterogeneity using tracers. Second technical annual progress report, October 1991--September 1992

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pope, G.A.; Sepehrnoori, K.

    1992-12-31

    This second annual report on innovative uses of tracers for reservoir characterization contains four sections each describing a novel use of oilfield tracers. The first section describes and illustrates the use of a new single-well tracer test to estimate wettability. This test consists of the injection of brine containing tracers followed by oil containing tracers, a shut-in period to allow some of the tracers to react, and then production of the tracers. The inclusion of the oil injection slug with tracers is unique to this test, and this is what makes the test work. We adapted our chemical simulator, UTCHEM,more » to enable us to study this tracer method and made an extensive simulation study to evaluate the effects of wettability based upon characteristic curves for relative permeability and capillary pressure for differing wetting states typical of oil reservoirs. The second section of this report describes a new method for analyzing interwell tracer data based upon a type-curve approach. Theoretical frequency response functions were used to build type curves of ``transfer function`` and ``phase spectrum`` that have dimensionless heterogeneity index as a parameter to characterize a stochastic permeability field. We illustrate this method by analyzing field tracer data. The third section of this report describes a new theory for interpreting interwell tracer data in terms of channeling and dispersive behavior for reservoirs. Once again, a stochastic approach to reservoir description is taken. The fourth section of this report describes our simulation of perfluorocarbon gas tracers. This new tracer technology developed at Brookhaven National Laboratory is being tested at the Elk Hills Naval Petroleum Reserve No. 1 in California. We report preliminary simulations made of these tracers in one of the oil reservoirs under evaluation with these tracers in this field. Our compostional simulator (UTCOMP) was used for this simulation study.« less

  3. Conceptual Model Evaluation using Advanced Parameter Estimation Techniques with Heat as a Tracer

    NASA Astrophysics Data System (ADS)

    Naranjo, R. C.; Morway, E. D.; Healy, R. W.

    2016-12-01

    Temperature measurements made at multiple depths beneath the sediment-water interface has proven useful for estimating seepage rates from surface-water channels and corresponding subsurface flow direction. Commonly, parsimonious zonal representations of the subsurface structure are defined a priori by interpretation of temperature envelopes, slug tests or analysis of soil cores. However, combining multiple observations into a single zone may limit the inverse model solution and does not take full advantage of the information content within the measured data. Further, simulating the correct thermal gradient, flow paths, and transient behavior of solutes may be biased by inadequacies in the spatial description of subsurface hydraulic properties. The use of pilot points in PEST offers a more sophisticated approach to estimate the structure of subsurface heterogeneity. This presentation evaluates seepage estimation in a cross-sectional model of a trapezoidal canal with intermittent flow representing four typical sedimentary environments. The recent improvements in heat as a tracer measurement techniques (i.e. multi-depth temperature probe) along with use of modern calibration techniques (i.e., pilot points) provides opportunities for improved calibration of flow models, and, subsequently, improved model predictions.

  4. Diagnostic accuracy of [99mTc]Tc-Sestamibi in the assessment of thyroid nodules

    PubMed Central

    Yordanova, Anna; Mahjoob, Soha; Lingohr, Philipp; Kalff, Jörg; Türler, Andreas; Palmedo, Holger; Biersack, Hans-Jürgen; Kristiansen, Glen; Farahati, Jamshid; Essler, Markus; Ahmadzadehfar, Hojjat

    2017-01-01

    [99mTc]Tc-Sestamibi (MIBI) is an increasingly used tool for evaluation of thyroid nodules. However, there is a lack of evidence about the accuracy of this method in the European population. The aim of this study was to assess the utility of MIBI for the differentiation of thyroid nodules in a large cohort. 161 patients underwent MIBI, followed by a thyroidectomy. We used a dual phase MIBI protocol. Interpretation of the images included a scoring system from 0 (absent) to 3 (increased); this was to provide a scale for the uptake of the thyroid nodule in comparison to the paranodular tissue. Additionally, we evaluated the tracer uptake trend in late images compared to early images. We used the final histopathology as the reference standard. Scores 0-1 in early images, scores 0-2 in late images, and an absence of increasing uptake in the thyroid nodule in late images, showed the best predictive values to exclude malignancy, respectively (negative predictive value (NPV) 89%). Highest sensitivity (91%) for malignant nodules was evident in early images with a score 1-3. Highest specificity (91%) was obtained when the negative was defined as an absence of uptake-increase, in the late images. This study confirms that the most valuable feature of MIBI is the high NPV. Thus, with the appropriate interpretation method, high sensitivity and specificity, and moderate PPV can be obtained. PMID:29212258

  5. Feasibility of Real-Time Near-Infrared Fluorescence Tracer Imaging in Sentinel Node Biopsy for Oral Cavity Cancer Patients.

    PubMed

    Christensen, Anders; Juhl, Karina; Charabi, Birgitte; Mortensen, Jann; Kiss, Katalin; Kjær, Andreas; von Buchwald, Christian

    2016-02-01

    Sentinel node biopsy (SNB) is an established method in oral squamous cell carcinoma (OSCC) for staging the cN0 neck and to select patients who will benefit from a neck dissection. Near-infrared fluorescence (NIRF) imaging has the potential to improve the SNB procedure by facilitating intraoperative visual identification of the sentinel lymph node (SN). The purpose of this study was to evaluate the feasibility of fluorescence tracer imaging for SN detection in conjunction with conventional radio-guided technique. Prospective study of patients with primary OSCC planned for tumor resection and SNB. Thirty patients were injected peritumorally with a bimodal tracer (ICG-99mTc-Nanocoll) followed by lymphoscintigraphy and SPECT/CT to define the SNs and their anatomic allocation preoperatively. SNs were detected intraoperatively with a hand-held gamma-probe and a hand-held NIRF camera. In 29 of 30 subjects (97%), all preoperatively defined SNs could be identified intraoperatively using a combination of radioactive and fluorescence guidance. A total of 94 SNs (mean 3, range 1-5) that were both radioactive and fluorescent ex vivo were harvested. Eleven of 94 SNs (12%) could only be identified in vivo using NIRF imaging, and the majority of those were located in level 1 close to the primary tumor. A combined fluorescent and radioactive tracer for SNB is feasible, and the additional use of NIRF imaging may improve the accuracy of SN identification in oral cancer patients. Intraoperative fluorescence guidance seems of particular value when SNs are located in close proximity to the injection site.

  6. Functional renal imaging: new trends in radiology and nuclear medicine.

    PubMed

    Durand, Emmanuel; Chaumet-Riffaud, Philippe; Grenier, Nicolas

    2011-01-01

    The objective of this work is to compare the characteristics of various techniques for functional renal imaging, with a focus on nuclear medicine and magnetic resonance imaging. Even with low spatial resolution and rather poor signal-to-noise ratio, classical nuclear medicine has the advantage of linearity and good sensitivity. It remains the gold standard technique for renal relative functional assessment. Technetium-99m ((99m)Tc)-labeled diethylenetriamine penta-acetate remains the reference glomerular tracer. Tubular tracers have been improved: (123)I- or (131)I-hippuran, (99m)Tc-MAG3 and, recently, (99m)Tc-nitrilotriacetic acid. However, advancement in molecular imaging has not produced a groundbreaking tracer. Renal magnetic resonance imaging with classical gadolinated tracers probably has potential in this domain but has a lack of linearity and, therefore, its value still needs evaluation. Moreover, the advent of nephrogenic systemic fibrosis has delayed its expansion. Other developments, such as diffusion or blood oxygen level-dependent imaging, may have a role in the future. The other modalities have a limited role in clinical practice for functional renal imaging. Copyright © 2011 Elsevier Inc. All rights reserved.

  7. Thermal Expansion Behavior in TcO2. Toward Breaking the Tc-Tc Bond.

    PubMed

    Reynolds, Emily; Zhang, Zhaoming; Avdeev, Maxim; Thorogood, Gordon J; Poineau, Frederic; Czerwinski, Kenneth R; Kimpton, Justin A; Kennedy, Brendan J

    2017-08-07

    The structure of TcO 2 between 25 and 1000 °C has been determined in situ using X-ray powder diffraction methods and is found to remain monoclinic in space group P2 1 /c. Thermal expansion in TcO 2 is highly anisotropic, with negative thermal expansion of the b axis observed above 700 °C. This is the result of an anomalous expansion along the a axis that is a consequence of weakening of the Tc-Tc bonds.

  8. PET Tracer 18F-Fluciclovine Can Detect Histologically Proven Bone Metastatic Lesions: A Preclinical Study in Rat Osteolytic and Osteoblastic Bone Metastasis Models.

    PubMed

    Oka, Shuntaro; Kanagawa, Masaru; Doi, Yoshihiro; Schuster, David M; Goodman, Mark M; Yoshimura, Hirokatsu

    2017-01-01

    18 F-Fluciclovine ( trans -1-amino-3- 18 F-fluorocyclobutanecarboxylic acid; anti - 18 F-FACBC) is a positron emission tomography (PET) tracer for diagnosing cancers (e.g., prostate and breast cancer). The most frequent metastatic organ of these cancers is bone. Fluciclovine-PET can visualize bony lesions in clinical practice; however, such lesions have not been described histologically. Methods: We investigated the potential of 14 C-fluciclovine in aiding the visualization of osteolytic and osteoblastic bone metastases (with histological analyses), compared with 3 H-2-deoxy-2-fluoro-D-glucose ( 3 H-FDG), 3 H-choline chloride ( 3 H-choline), and 99m Tc-hydroxymethylene diphosphonate ( 99m Tc-HMDP) by using triple-tracer autoradiography in rat breast cancer osteolytic (on day 12 ± 1 postinjection of MRMT-1) and prostate cancer osteoblastic (on day 20 ± 3 postinjection of AT6.1) metastatic models. Results: The distribution patterns of 14 C-fluciclovine, 3 H-FDG, and 3 H-choline, but not 99m Tc-HMDP, were similar in both models, and the lesions where these tracers accumulated were, histologically, typical osteolytic and osteoblastic lesions. 99m Tc-HMDP accumulated mostly in osteoblastic lesions. 14 C-fluciclovine could visualize the osteolytic lesions as early as day 6 postinjection of MRMT-1. However, differential distributions in 14 C-fluciclovine and 3 H-FDG existed, based on histological differences: low 14 C-fluciclovine and high 3 H-FDG accumulation in osteolytic lesions with inflammation. In the osteoblastic metastatic model, visualization of osteoblastic lesions with 14 C-fluciclovine was not clear, yet clearer than with 3 H-FDG. Although half of the osteoblastic lesions with 14 C-fluciclovine accumulation showed negligible 3 H-choline accumulation in comparison, they were histologically similar to lesions with marked 14 C-fluciclovine and 3 H-choline accumulation. Conclusion: These results suggest that fluciclovine-PET can visualize true osteolytic and

  9. PET Tracer 18F-Fluciclovine Can Detect Histologically Proven Bone Metastatic Lesions: A Preclinical Study in Rat Osteolytic and Osteoblastic Bone Metastasis Models

    PubMed Central

    Oka, Shuntaro; Kanagawa, Masaru; Doi, Yoshihiro; Schuster, David M.; Goodman, Mark M.; Yoshimura, Hirokatsu

    2017-01-01

    18F-Fluciclovine (trans-1-amino-3-18F-fluorocyclobutanecarboxylic acid; anti-18F-FACBC) is a positron emission tomography (PET) tracer for diagnosing cancers (e.g., prostate and breast cancer). The most frequent metastatic organ of these cancers is bone. Fluciclovine-PET can visualize bony lesions in clinical practice; however, such lesions have not been described histologically. Methods: We investigated the potential of 14C-fluciclovine in aiding the visualization of osteolytic and osteoblastic bone metastases (with histological analyses), compared with 3H-2-deoxy-2-fluoro-D-glucose (3H-FDG), 3H-choline chloride (3H-choline), and 99mTc-hydroxymethylene diphosphonate (99mTc-HMDP) by using triple-tracer autoradiography in rat breast cancer osteolytic (on day 12 ± 1 postinjection of MRMT-1) and prostate cancer osteoblastic (on day 20 ± 3 postinjection of AT6.1) metastatic models. Results: The distribution patterns of 14C-fluciclovine, 3H-FDG, and 3H-choline, but not 99mTc-HMDP, were similar in both models, and the lesions where these tracers accumulated were, histologically, typical osteolytic and osteoblastic lesions. 99mTc-HMDP accumulated mostly in osteoblastic lesions. 14C-fluciclovine could visualize the osteolytic lesions as early as day 6 postinjection of MRMT-1. However, differential distributions in 14C-fluciclovine and 3H-FDG existed, based on histological differences: low 14C-fluciclovine and high 3H-FDG accumulation in osteolytic lesions with inflammation. In the osteoblastic metastatic model, visualization of osteoblastic lesions with 14C-fluciclovine was not clear, yet clearer than with 3H-FDG. Although half of the osteoblastic lesions with 14C-fluciclovine accumulation showed negligible 3H-choline accumulation in comparison, they were histologically similar to lesions with marked 14C-fluciclovine and 3H-choline accumulation. Conclusion: These results suggest that fluciclovine-PET can visualize true osteolytic and osteoblastic bone metastatic lesions

  10. Secondary Ion Mass Spectrometry for Mg Tracer Diffusion: Issues and Solutions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tuggle, Jay; Giordani, Andrew; Kulkarni, Nagraj S

    2014-01-01

    A Secondary Ion Mass Spectrometry (SIMS) method has been developed to measure stable Mg isotope tracer diffusion. This SIMS method was then used to calculate Mg self- diffusivities and the data was verified against historical data measured using radio tracers. The SIMS method has been validated as a reliable alternative to the radio-tracer technique for the measurement of Mg self-diffusion coefficients and can be used as a routine method for determining diffusion coefficients.

  11. The utility of 99mTc-EDDA/HYNIC-TOC scintigraphy for assessment of lung lesions in patients with neuroendocrine tumors.

    PubMed

    Pavlovic, S; Artiko, V; Sobic-Saranovic, D; Damjanovic, S; Popovic, B; Jakovic, R; Petrasinovic, Z; Jaksic, E; Todorovic-Tirnanic, M; Saranovic, D; Micev, M; Novosel, S; Nikolic, N; Obradovic, V

    2010-01-01

    Our aim was to assess clinical utility of 99mTc-EDDA/HYNIC-TOC scintigraphy for evaluation of lung lesions in patients with neuroendocrine tumors (NETs). Single photon emission computed tomography (SPECT) of the thorax and whole body scintigraphy were performed in 34 patients using 99mTc-EDDA/HYNIC-TOC. Visual assessment was complemented by semiquantitative evaluation based on tumor to non-tumor (T/NT) ratio. Clinical, laboratory, and histological findings served as the standard for comparison. Enhanced tracer uptake was observed on both SPECT and whole body scintigraphy in 29 of 34 patients (88% sensitivity). T/NT ratios were significantly higher on SPECT than whole body images (2.96+/-1.07 vs.1.70+/-0.43, p 99mTc-EDDA/Hynic-TOC, lung involvement of NETs, T/NT ratio.

  12. Wear measurement using radioactive tracer technique based on proton, deuteron and α-particle induced nuclear reactions on molybdenum

    NASA Astrophysics Data System (ADS)

    Ditrói, F.; Tárkányi, F.; Takács, S.

    2012-11-01

    Excitation functions of light ion induced nuclear reactions on natural molybdenum have been studied in the frame of a systematic investigation of charged particle induced nuclear reactions on metals for various applications. Excitation functions of 93,94g,94m,95g,95m,96,99mTc, 90,93m,99Mo, 90,91m,92m,95m,95g,96Nb and 88,89Zr were measured up to 50 MeV deuteron energy Tárkányi et al., 2012 [1], 93m,93g,94m,94g,95m,95g,96g,99mTc, 90,93m,99Mo, 90,92m,95m,95g,96Nb and 88,89Zr were measured up to 40 MeV proton energy Tárkányi et al., 2012 [2] and 93m,93g,94m,94g,95m,95g,96g,99mTc, 93m,99Mo, 90Nb, 94,95,97,103Ru and 88Zr were measured up to 40 MeV alpha energy Ditrói et al., 2012 [3] by using the stacked foil technique and activation method. The results for 3He induced reactions on natural Mo were taken from the literature Comparetto and Qaim, 1980 [4]. According to their half-lives, from the above listed radionuclides the 95m,96Tc, 91m,92m,95m,95gNb, 99Mo, 103,97Ru and 88Zr are suitable candidates for wear measurement by using thin layer activation (TLA) method. The goal of this work was to determine the necessary nuclear data for TLA of the above radionuclides and to prove their applicability for wear measurements.

  13. Quantitative studies of bone in postmenopausal women using (18)F-fluoride and (99m)Tc-methylene diphosphonate.

    PubMed

    Blake, Glen M; Park-Holohan, So-Jin; Fogelman, Ignac

    2002-03-01

    Quantitative radionuclide studies of bone using the short-lived tracers (18)F-fluoride and (99m)Tc-methylene diphosphonate (MDP) are an alternative method to biochemical markers of bone turnover for investigating the dynamic state of the skeleton. In this study we evaluated their use to quantify bone turnover in women receiving antiresorptive therapy compared with that of untreated control subjects. The patients were 69 healthy postmenopausal women. Twenty-six women were receiving hormone replacement therapy (HRT) and 43 were untreated age-matched control subjects. After bolus injection of (18)F-fluoride (1 MBq), (99m)Tc-MDP (1 MBq), (51)Cr-ethylenediaminetetraacetic acid (3 MBq), and (125)I-labeled human serum albumin (0.25 MBq), multiple blood samples and urine collections were taken between 0 and 4 h. The clearance to bone mineral K(bone) was first evaluated using the area under the plasma concentration curve (AUC) on the assumption that the rate constant k(4) for the outflow of tracer from bone was negligibly small. AUC values of K(bone) were then compared with those found using a compartmental model method that allowed k(4) to be fitted as a free parameter. Using the AUC method the mean plus minus SD for K(bone) for the 2 tracers were: (18)F-fluoride, 61.8 plus minus 12.0 mL center dot min(-1) (HRT group) versus 67.2 plus minus 12.6 mL center dot min(-1) (control group) (P = 0.045); and (99m)Tc-MDP, 40.3 plus minus 8.2 mL center dot min(-1) (HRT group) versus 44.2 plus minus 7.6 mL center dot min(-1) (control group) (P = 0.024). Values for the 2 tracers in individual patients were moderately well correlated (r = 0.76; P < 0.001). Using the compartmental model method, k(4) for (18)F-fluoride was shown to lie in the range 0--0.0025 min(-1) with a best-fit value of 0.0018 min(-1). Values of K(bone) determined using k(4) = 0.0018 min(-1) were highly correlated with the AUC values (r = 0.989; SEE = 2.05 mL center dot min(-1)) with numeric values that were larger by

  14. Effective visualization of suppressed thyroid tissue by means of baseline 99mTc-methoxy isobutyl isonitrile in comparison with 99mTc-pertechnetate scintigraphy after TSH stimulation.

    PubMed

    Vattimo, A; Bertelli, P; Burroni, L

    1992-01-01

    Baseline 99mTc-MIBI thyroid scintigraphy was compared with 99mTc-pertechnetate scintigraphy after TSH stimulation in seven patients with suppressed thyroid tissue due to an autonomously functioning thyroid nodule (AFTN). In all patients the suppressed thyroid tissue was visualized by means of both baseline 99mTc-MIBI and post-TSH 99mTc-pertechnetate scintigraphy, and in some cases the former technique provided better visualization. In one patient presenting a "warm" nodule T3-suppression did not affect the nodular/extranodular uptake ratio of 99mTc-MIBI, whereas the 99mTc-pertechnetate uptake ratio increased significantly. This leads us to hypothesize that the thyroid uptake of 99mTc-MIBI is not related to TSH control, but rather to other mechanisms such as the blood flow. Since exogenous TSH is no longer available, 99mTc-MIBI scintigraphy can be successfully used in the place of repeated 99mTc-pertechnetate scintigraphy after TSH stimulation in the assessment of AFTN.

  15. IMAGE Project: Results of Laboratory Tests on Tracers for Supercritical Conditions.

    NASA Astrophysics Data System (ADS)

    Brandvoll, Øyvind; Opsahl Viig, Sissel; Nardini, Isabella; Muller, Jiri

    2016-04-01

    The use of tracers is a well-established technique for monitoring dynamic behaviour of water and gas through a reservoir. In geothermal reservoirs special challenges are encountered due to high temperatures and pressures. In this work, tracer candidates for monitoring water at supercritical conditions (temperature > 374°C, pressure ca 218 bar), are tested in laboratory experiments. Testing of tracers at supercritical water conditions requires experimental set-ups which tolerate harsh conditions with respect to high temperature and pressure. In addition stringent HES (health, environment and safety) factors have to be taken into consideration when designing and performing the experiments. The setup constructed in this project consists of a pressure vessel, high pressure pump, instrumentation for pressure and temperature control and instrumentation required for accurate sampling of tracers. In order to achieve accurate results, a special focus has been paid to the development of the tracer sampling technique. Perfluorinated cyclic hydrocarbons (PFCs) have been selected as tracer candidates. This group of compounds is today commonly used as gas tracers in oil reservoirs. According to the literature they are stable at temperatures up to 400°C. To start with, five PFCs have been tested for thermal stability in static experiments at 375°C and 108 bar in the experimental setup described above. The tracer candidates will be further tested for several months at the relevant conditions. Preliminary results indicate that some of the PFC compounds show stability after three months. However, in order to arrive at conclusive results, the experiments have to be repeated over a longer period and paying special attention to more accurate sampling procedures.

  16. Biological tracer method

    DOEpatents

    Strong-Gunderson, Janet M.; Palumbo, Anthony V.

    1998-01-01

    The present invention is a biological tracer method for characterizing the movement of a material through a medium, comprising the steps of: introducing a biological tracer comprising a microorganism having ice nucleating activity into a medium; collecting at least one sample of the medium from a point removed from the introduction point; and analyzing the sample for the presence of the biological tracer. The present invention is also a method for using a biological tracer as a label for material identification by introducing a biological tracer having ice nucleating activity into a material, collecting a sample of a portion of the labelled material and analyzing the sample for the presence of the biological tracer.

  17. Biological tracer method

    DOEpatents

    Strong-Gunderson, J.M.; Palumbo, A.V.

    1998-09-15

    The present invention is a biological tracer method for characterizing the movement of a material through a medium, comprising the steps of: introducing a biological tracer comprising a microorganism having ice nucleating activity into a medium; collecting at least one sample of the medium from a point removed from the introduction point; and analyzing the sample for the presence of the biological tracer. The present invention is also a method for using a biological tracer as a label for material identification by introducing a biological tracer having ice nucleating activity into a material, collecting a sample of a portion of the labelled material and analyzing the sample for the presence of the biological tracer. 2 figs.

  18. 2-Phenylbenzothiazole conjugated with cyclopentadienyl tricarbonyl [CpM(CO)3] (M = Re, (99m)Tc) complexes as potential imaging probes for β-amyloid plaques.

    PubMed

    Jia, Jianhua; Cui, Mengchao; Dai, Jiapei; Liu, Boli

    2015-04-14

    Technetium-99m-labeled cyclopentadienyl tricarbonyl complexes conjugated with the 2-phenylbenzothiazole binding motif were synthesized. The rhenium surrogates , , and were demonstrated to have moderate to high affinities for Aβ1-42 aggregates with Ki values of 142, 76, 64 and 24 nM, respectively. During the fluorescence staining of brain sections of transgenic mice and patients with Alzheimer's disease, these rhenium complexes demonstrated perfect and intense labeling of Aβ plaques. Moreover, in in vitro autoradiography, (99m)Tc-labeled complexes clearly detected β-amyloid plaques on sections of brain tissue from transgenic mice, which confirmed the sufficient affinity of these tracers for Aβ plaques. However, these compounds did not show desirable properties in vivo, especially showing poor brain uptake (below 0.5% ID g(-1)), which will hinder the further development of these tracers as brain imaging agents. Nonetheless, it is encouraging that these (99m)Tc-labeled complexes designed by a conjugate approach displayed sufficient affinities for Aβ plaques.

  19. Significance of /sup 99m/Tc-sulfur colloid splenic image in malignant melanoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berjian, R.A.; Parthasarathy, K.L.; Didolkar, M.S.

    To evaluate the clinical significance of /sup 99m/Tc-sulfur-colloid (TcSC) spleen scan findings in patients with malignant melanoma, a retrospective study was undertaken. Eighty-one patients with histologically proven malignant melanoma who received treatment in Roswell Park during a five-year period were included in this study. The scans were analyzed for spleen size, differential uptake of the tracer in liver and spleen, and for the presence of metastases in these two organs. These data were compared with stage of disease, survival, and autopsy findings. Significant correlation was found between the splenic size as measured on the scintiscan and at autopsy examination. Themore » spleen size was found to be normal in 92% of the patients in early melanoma. The median survival of patients who had a normal-sized spleen by scan criteria was found to be longer than those who had splenomegaly. No significant difference in survival was noted between the patients with and without augmented splenic uptake of TcSC. Only a small number (17.7%) of patients with augmented splenic uptake had splenic metastases; hence, the possible role of immunological factors was considered.« less

  20. Impact of solvent granularity and layering on tracer hydrodynamics in confinement.

    PubMed

    Bollinger, Jonathan A; Carmer, James; Jain, Avni; Truskett, Thomas M

    2016-11-28

    Classic hydrodynamic arguments establish that when a spherical tracer particle is suspended between parallel walls, tracer-wall coupling mediated by the solvent will cause the tracer to exhibit position-dependent diffusivity. We investigate how the diffusivity profiles of confined tracers are impacted by the diameter size-ratio of the tracer to solvent: starting from the classic limit of infinite size-ratio (i.e., continuum solvent), we consider size-ratios of four or less to examine how hydrodynamic predictions are disrupted for systems where the tracer and solvent are of similar scale. We use computer simulations and techniques based on the Fokker-Planck formalism to calculate the diffusivity profiles of hard-sphere tracer particles in hard-sphere solvents, focusing on the dynamics perpendicular to the walls. Given wall separations of several tracer diameters, we first consider confinement between hard walls, where anisotropic structuring at the solvent lengthscale generates inhomogeneity in the tracer free-energy landscape and undermines hydrodynamic predictions locally. We then introduce confining planes that we term transparent walls, which restrict tracer and solvent center-accessibilities while completely eliminating static anisotropy, and reveal position-dependent signatures in tracer diffusivity solely attributable to confinement. With or without suppressing static heterogeneity, we find that tracer diffusivity increasingly deviates on a local basis from hydrodynamic predictions at smaller size-ratios. However, hydrodynamic theory still approximately captures spatially-averaged dynamics across the pores even for very small tracer-solvent size-ratios over a wide range of solvent densities and wall separations.

  1. Comparison of thermal, salt and dye tracing to estimate shallow flow velocities: Novel triple-tracer approach

    NASA Astrophysics Data System (ADS)

    Abrantes, João R. C. B.; Moruzzi, Rodrigo B.; Silveira, Alexandre; de Lima, João L. M. P.

    2018-02-01

    The accurate measurement of shallow flow velocities is crucial to understand and model the dynamics of sediment and pollutant transport by overland flow. In this study, a novel triple-tracer approach was used to re-evaluate and compare the traditional and well established dye and salt tracer techniques with the more recent thermal tracer technique in estimating shallow flow velocities. For this purpose a triple tracer (i.e. dyed-salted-heated water) was used. Optical and infrared video cameras and an electrical conductivity sensor were used to detect the tracers in the flow. Leading edge and centroid velocities of the tracers were measured and the correction factors used to determine the actual mean flow velocities from tracer measured velocities were compared and investigated. Experiments were carried out for different flow discharges (32-1813 ml s-1) on smooth acrylic, sand, stones and synthetic grass bed surfaces with 0.8, 4.4 and 13.2% slopes. The results showed that thermal tracers can be used to estimate shallow flow velocities, since the three techniques yielded very similar results without significant differences between them. The main advantages of the thermal tracer were that the movement of the tracer along the measuring section was more easily visible than it was in the real image videos and that it was possible to measure space-averaged flow velocities instead of only one velocity value, with the salt tracer. The correction factors used to determine the actual mean velocity of overland flow varied directly with Reynolds and Froude numbers, flow velocity and slope and inversely with flow depth and bed roughness. In shallow flows, velocity estimation using tracers entails considerable uncertainty and caution must be taken with these measurements, especially in field studies where these variables vary appreciably in space and time.

  2. Rapid diagnosis of occult abscesses using sup 99m Tc-labeled monoclonal antibodies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coons, T.A.; Rhodes, B.A.; Thakur, M.L.

    1991-01-01

    Acute infections, such as appendicitis and occult infections in AIDS patients, can be diagnosed within two hours by gamma scintigraphy after i.v. administration of {sup 99m}Tc labeled antibodies reactive with human granulocytes. The antibody, murine IgM anti-SSEA-1, is partially reduced using Sn(II) to expose and protect reactive sulfide groups. The antibody is then purified, stannous tartrate and stabilizers are added, and the mixture is lyophilized. To label, sodium pertechnetate is added. After a 15 minute incubation the tracer drug is injected. The rate of accumulation and degree of concentration at the site of infection is presumptively determinative of the severitymore » of the infection. Acceptance criteria and tests for the {sup 99m}Tc labeled antibody product have been established and validated. Greater than 93% of the {sup 99m}Tc is firmly bound to the protein as determined by quantitative HPLC. Radiochemical impurities, colloidal {sup 99m}Tc and free pertechnetate are together less than 4% as determined by thin layer chromatography. The immunoreactive fraction, measured by binding to solid phase antigen, and affinity measured be ELISA, are unchanged by the {sup 99m}Tc-direct labeling process. Two hour blood clearance in rats is within 90% of the value of the {sup 125}I labeled analog. The immunoreactive fraction decreases less than 10% when incubated in human plasma for 24 hours. This method has been compared to other direct labeling methods, and found to give higher radiochemical yields. 5 figs.« less

  3. Which is the best strategy for diagnosing bronchial carcinoid tumours? The role of dual tracer PET/CT scan.

    PubMed

    Lococo, Filippo; Treglia, Giorgio

    2014-01-01

    Bronchial carcinoids (BC) are rare well-differentiated neuroendocrine tumours (NET) sub-classified into typical (TC) and atypical carcinoids (AC). A correct pathological identification in the pre-operative setting is a key element for planning the best strategy of care, considering the different biological behavior of TC and AC. Controversial results have been reported on the diagnostic accuracy of fluorine-18-fluorodeoxyglucose positron emission tomography/computed tomography ((18)F-FDG PET/CT) in BC. On the other hand, there is increasing evidence supporting the use of PET with somatostatin analogues (dotanoc, dotatoc or dotatate) labeled with gallium-68 ((68)Ga) in pulmonary NET. Based on information obtained by using different radiopharmaceuticals and different (68)Ga labeled somatostatin analogues in PET and PET/CT studies, we are able to diagnose BC. In conclusion, by using somatostatin receptor imaging and (18)F-FDG PET/CT scan, we can differentiate BC from benign pulmonary lesions and TC from AC by specific diagnostic patterns. Clinical trials on larger groups of patient would allow for a better and "tailored" therapeutic strategy in NET patients using dual-tracer PET/CT to identify BC and distinguish between TC and AC.

  4. Measuring functioning hepatocytes using Tc-99m galactosylneoglycoalbumin (Tc-NGA)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stadalnik, R.C.; Vera, D.R.; Quadro, R.E.

    1984-01-01

    Tc-NGA is a synthetic ligand which binds only to hepatic binding protein (HBP), a receptor found only in the liver. It exhibits the properties of high tissue specificity, affinity-dependent uptake, and dose-dependent uptake. Tc-NGA provides an opportunity to study the functioning hepatocyte. The authors evaluated the usefulness of this technique in patients with hepatitis and hepatoma. After intravenous administration of 5 mCi Tc-NGA, dynamic images were acquired for 30 minutes followed by static views. Estimates of HBP concentrations were obtained by kinetic analysis of blood and liver time-activity curves. Kinetic estimates (reduced chi-squares < 3.0) of HBP correlated well withmore » the clinical course and histology. For example, a patient with hepatoma whose calculated receptor population (functioning hepatocytes) was 3.0 +- 0.9 x 10/sup -7/ mole, which is the normal range, is doing well undergoing chemotherapy. Liver biopsy demonstrated normal liver tissue except for the hepatoma. Another patient with hepatoma who had a severely depressed receptor population, 1.2 +- 0.2 x 10/sup -8/ mole, expired one week after the study. Liver biopsy demonstrated practically no normal tissue. Thus, by means of a complementary, receptor radiopharmaceutical and mathematical model, one should be able to quantitatively follow hepatocyte function and predict response to a therapeutic regimen.« less

  5. Travel-time-based thermal tracer tomography

    NASA Astrophysics Data System (ADS)

    Somogyvári, Márk; Bayer, Peter; Brauchler, Ralf

    2016-05-01

    Active thermal tracer testing is a technique to get information about the flow and transport properties of an aquifer. In this paper we propose an innovative methodology using active thermal tracers in a tomographic setup to reconstruct cross-well hydraulic conductivity profiles. This is facilitated by assuming that the propagation of the injected thermal tracer is mainly controlled by advection. To reduce the effects of density and viscosity changes and thermal diffusion, early-time diagnostics are used and specific travel times of the tracer breakthrough curves are extracted. These travel times are inverted with an eikonal solver using the staggered grid method to reduce constraints from the pre-defined grid geometry and to improve the resolution. Finally, non-reliable pixels are removed from the derived hydraulic conductivity tomograms. The method is applied to successfully reconstruct cross-well profiles as well as a 3-D block of a high-resolution fluvio-aeolian aquifer analog data set. Sensitivity analysis reveals a negligible role of the injection temperature, but more attention has to be drawn to other technical parameters such as the injection rate. This is investigated in more detail through model-based testing using diverse hydraulic and thermal conditions in order to delineate the feasible range of applications for the new tomographic approach.

  6. Glowing clay: Real time tracing using a suite of novel clay based fluorescent tracers

    NASA Astrophysics Data System (ADS)

    Hardy, Robert; Quinton, John; Pates, Jackie; Coogan, Mike

    2015-04-01

    Clay is one of the most mobile fractions of soil due to its small particle size. It is also known to sorb many chemicals, such as nutrients (notably phosphorus), agrochemicals and heavy metals. The movement of clay is therefore linked with the transport and fate of these substances. A novel fluorescent clay tracing suite has been produced, together with an imaging technique. This suite consists of qualitative clay tracers, using rhodamine based fluorophores, and quantitative clay tracers, using metal based fluorophores. Efforts have also been made to allow integration of commercially available tracers, which are silt and sand sized. The clay tracers exploit the high affinity that montmorillonite has for Rhodamine B and Ru(bpy)3. This allows for an extremely thin layer of the fluorophore to be sorbed onto the clay's surface, in much that same way as materials in the natural environment will bind to clay. The tracer that is produced retains key chemical and physical properties of clay, such as size, shape and density. The retention of these micro-properties results in the retention of macro-properties, such as tendency to aggregate and cracking on drying. Imaging techniques have been developed to analyse these tracers. The imaging system uses diffused laser light to excite the tracer and a modified DSLR camera to image the soil surface. The images have been compiled into a time lapse video showing the movement of clay over the course of a rainfall event. This is the first time that the quantitative movement of clay has been recorded over a soil surface in real time. 4D data can be extracted from the images allowing the spatial location and intensity of tracer to be monitored over time, with mm precision and on the timescale of seconds. As the system can also work with a commercial tracer it is possible to investigate the movement of particles of almost any size and over a range of scales from soil box to hillside. This allows users to access this technique without

  7. A deliberate tracer experiment in Santa Monica Basin. [for ocean density strata diffusion

    NASA Technical Reports Server (NTRS)

    Ledwell, J. R.; Broecker, W. S.; Watson, A. J.

    1986-01-01

    A tracer technique was developed for measurements of diffusion across oceanic density strata using SF6 and perfluorodecalin (PFD) tracers in the Santa Monica Basin. Fifty days after injection, the tracers were found to have mixed along the isopycnal surface to nearly every part of the basin. The diapycnal spreading of the tracer distributions yielded an apparent eddy diffusivity of 0.33 + or - 0.08 sq cm/s at the ambient density gradient of 4.0 + or - 0.5 x 10 to the -9th g/cm to the 4th.

  8. Enhanced 99 Tc retention in glass waste form using Tc(IV)-incorporated Fe minerals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Um, Wooyong; Luksic, Steven A.; Wang, Guohui

    Technetium (99Tc) immobilization by doping into iron oxide mineral phases may alleviate the problems with Tc volatility during vitrification of nuclear waste. Reduced Tc, Tc(IV), substitutes for Fe(III) in the crystal structure by a process of Tc reduction from Tc(VII) to Tc(IV) followed by co-precipitation of Fe oxide minerals. Two Tc-incorporated Fe minerals (Tc-goethite and Tc-magnetite/maghemite) were prepared and tested for Tc retention in glass melt samples at temperatures between 600 – 1,000 oC. After being cooled, the solid glass specimens prepared at different temperatures were analyzed for Tc oxidation state using Tc K-edge XANES. In most samples, Tc wasmore » partially oxidized from Tc(IV) to Tc(VII) as the melt temperature increased. However, Tc retention in glass melt samples prepared using Tc-incorporated Fe minerals were moderately higher than in glass prepared using KTcO4 because of limited and delayed Tc volatilization.« less

  9. Comparison of Tc-99m maraciclatide and Tc-99m sestamibi molecular breast imaging in patients with suspected breast cancer.

    PubMed

    O'Connor, Michael K; Morrow, Melissa M B; Hunt, Katie N; Boughey, Judy C; Wahner-Roedler, Dietlind L; Conners, Amy Lynn; Rhodes, Deborah J; Hruska, Carrie B

    2017-12-01

    Molecular breast imaging (MBI) performed with 99m Tc sestamibi has been shown to be a valuable technique for the detection of breast cancer. Alternative radiotracers such as 99m Tc maraciclatide may offer improved uptake in breast lesions. The purpose of this study was to compare relative performance of 99m Tc sestamibi and 99m Tc maraciclatide in patients with suspected breast cancer, using a high-resolution dedicated gamma camera for MBI. Women with breast lesions suspicious for malignancy were recruited to undergo two MBI examinations-one with 99m Tc sestamibi and one with 99m Tc maraciclatide. A radiologist interpreted MBI studies in a randomized, blinded fashion to assign an assessment score (1-5) and measured lesion size. Lesion-to-background (L/B) ratio was measured with region-of-interest analysis. Among 39 analyzable patients, 21 malignant tumors were identified in 21 patients. Eighteen of 21 tumors (86%) were seen on 99m Tc sestamibi MBI and 19 of 21 (90%) were seen on 99m Tc maraciclatide MBI (p = 1). Tumor extent measured with both radiopharmaceuticals correlated strongly with pathologic size ( 99m Tc sestamibi, r = 0.84; 99m Tc maraciclatide, r = 0.81). The L/B ratio in detected breast cancers was similar for the two radiopharmaceuticals: 1.55 ± 0.36 (mean ± S.D.) for 99m Tc sestamibi and 1.62 ± 0.37 (mean ± S.D.) for 99m Tc maraciclatide (p = 0.53). No correlation was found between the L/B ratio and molecular subtype for 99m Tc sestamibi (r s  = 0.12, p = 0.63) or 99m Tc maraciclatide (r s  = -0.12, p = 0.64). Of 20 benign lesions, 10 (50%) were seen on 99m Tc sestamibi and 9 of 20 (45%) were seen on 99m Tc maraciclatide images (p = 0.1). The average L/B ratio for benign lesions was 1.34 ±0.40 (mean ±S.D.) for 99m Tc sestamibi and 1.41 ±0.52 (mean ±S.D.) for 99m Tc maraciclatide (p = 0.75). Overall diagnostic performance was similar for both radiopharmaceuticals. AUC from ROC

  10. A standardized method for the construction of tracer specific PET and SPECT rat brain templates: validation and implementation of a toolbox.

    PubMed

    Vállez Garcia, David; Casteels, Cindy; Schwarz, Adam J; Dierckx, Rudi A J O; Koole, Michel; Doorduin, Janine

    2015-01-01

    High-resolution anatomical image data in preclinical brain PET and SPECT studies is often not available, and inter-modality spatial normalization to an MRI brain template is frequently performed. However, this procedure can be challenging for tracers where substantial anatomical structures present limited tracer uptake. Therefore, we constructed and validated strain- and tracer-specific rat brain templates in Paxinos space to allow intra-modal registration. PET [18F]FDG, [11C]flumazenil, [11C]MeDAS, [11C]PK11195 and [11C]raclopride, and SPECT [99mTc]HMPAO brain scans were acquired from healthy male rats. Tracer-specific templates were constructed by averaging the scans, and by spatial normalization to a widely used MRI-based template. The added value of tracer-specific templates was evaluated by quantification of the residual error between original and realigned voxels after random misalignments of the data set. Additionally, the impact of strain differences, disease uptake patterns (focal and diffuse lesion), and the effect of image and template size on the registration errors were explored. Mean registration errors were 0.70 ± 0.32 mm for [18F]FDG (n = 25), 0.23 ± 0.10mm for [11C]flumazenil (n = 13), 0.88 ± 0.20 mm for [11C]MeDAS (n = 15), 0.64 ± 0.28 mm for [11C]PK11195 (n = 19), 0.34 ± 0.15 mm for [11C]raclopride (n = 6), and 0.40 ± 0.13 mm for [99mTc]HMPAO (n = 15). These values were smallest with tracer-specific templates, when compared to the use of [18F]FDG as reference template (p<0.001). Additionally, registration errors were smallest with strain-specific templates (p<0.05), and when images and templates had the same size (p ≤ 0.001). Moreover, highest registration errors were found for the focal lesion group (p<0.005) and the diffuse lesion group (p = n.s.). In the voxel-based analysis, the reported coordinates of the focal lesion model are consistent with the stereotaxic injection procedure. The use of PET/SPECT strain- and tracer

  11. A Standardized Method for the Construction of Tracer Specific PET and SPECT Rat Brain Templates: Validation and Implementation of a Toolbox

    PubMed Central

    Vállez Garcia, David; Casteels, Cindy; Schwarz, Adam J.; Dierckx, Rudi A. J. O.; Koole, Michel; Doorduin, Janine

    2015-01-01

    High-resolution anatomical image data in preclinical brain PET and SPECT studies is often not available, and inter-modality spatial normalization to an MRI brain template is frequently performed. However, this procedure can be challenging for tracers where substantial anatomical structures present limited tracer uptake. Therefore, we constructed and validated strain- and tracer-specific rat brain templates in Paxinos space to allow intra-modal registration. PET [18F]FDG, [11C]flumazenil, [11C]MeDAS, [11C]PK11195 and [11C]raclopride, and SPECT [99mTc]HMPAO brain scans were acquired from healthy male rats. Tracer-specific templates were constructed by averaging the scans, and by spatial normalization to a widely used MRI-based template. The added value of tracer-specific templates was evaluated by quantification of the residual error between original and realigned voxels after random misalignments of the data set. Additionally, the impact of strain differences, disease uptake patterns (focal and diffuse lesion), and the effect of image and template size on the registration errors were explored. Mean registration errors were 0.70±0.32mm for [18F]FDG (n = 25), 0.23±0.10mm for [11C]flumazenil (n = 13), 0.88±0.20 mm for [11C]MeDAS (n = 15), 0.64±0.28mm for [11C]PK11195 (n = 19), 0.34±0.15mm for [11C]raclopride (n = 6), and 0.40±0.13mm for [99mTc]HMPAO (n = 15). These values were smallest with tracer-specific templates, when compared to the use of [18F]FDG as reference template (p&0.001). Additionally, registration errors were smallest with strain-specific templates (p&0.05), and when images and templates had the same size (p≤0.001). Moreover, highest registration errors were found for the focal lesion group (p&0.005) and the diffuse lesion group (p = n.s.). In the voxel-based analysis, the reported coordinates of the focal lesion model are consistent with the stereotaxic injection procedure. The use of PET/SPECT strain- and tracer-specific templates allows

  12. Enhanced 99Tc retention in glass waste form using Tc(IV)-incorporated Fe minerals

    DOE PAGES

    Um, Wooyong; Luksic, Steven A.; Wang, Guohui; ...

    2017-09-07

    We present that technetium ( 99Tc) immobilization by doping into iron oxide mineral phases may alleviate the problems with Tc volatility during vitrification of nuclear waste. Because reduced Tc, Tc(IV), substitutes for Fe(III) in the crystal structure by a process of Tc reduction from Tc(VII) to Tc(IV) followed by co-precipitation of Fe oxide minerals, two Tc-incorporated Fe minerals (Tc-goethite and Tc-magnetite/maghemite) were prepared and tested for Tc retention in glass melt samples at temperatures between 600 and 1000 °C. After being cooled, the solid glass specimens prepared at different temperatures at 600, 800, and 1000 °C were analyzed for Tcmore » oxidation state using Tc K-edge XANES. In most samples, Tc was partially (<60%) oxidized from Tc(IV) to Tc(VII) as the melt temperature increased up to 600 °C. However, most of Tc(IV) was completely (>95%) oxidized to Tc(VII) at temperature above 800 °C. Tc retention in glass melt samples prepared using Tc-incorporated Fe minerals were slightly higher (~10%) than in glass prepared using KTcO4 because of limited and delayed Tc volatilization.« less

  13. Enhanced 99Tc retention in glass waste form using Tc(IV)-incorporated Fe minerals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Um, Wooyong; Luksic, Steven A.; Wang, Guohui

    We present that technetium ( 99Tc) immobilization by doping into iron oxide mineral phases may alleviate the problems with Tc volatility during vitrification of nuclear waste. Because reduced Tc, Tc(IV), substitutes for Fe(III) in the crystal structure by a process of Tc reduction from Tc(VII) to Tc(IV) followed by co-precipitation of Fe oxide minerals, two Tc-incorporated Fe minerals (Tc-goethite and Tc-magnetite/maghemite) were prepared and tested for Tc retention in glass melt samples at temperatures between 600 and 1000 °C. After being cooled, the solid glass specimens prepared at different temperatures at 600, 800, and 1000 °C were analyzed for Tcmore » oxidation state using Tc K-edge XANES. In most samples, Tc was partially (<60%) oxidized from Tc(IV) to Tc(VII) as the melt temperature increased up to 600 °C. However, most of Tc(IV) was completely (>95%) oxidized to Tc(VII) at temperature above 800 °C. Tc retention in glass melt samples prepared using Tc-incorporated Fe minerals were slightly higher (~10%) than in glass prepared using KTcO4 because of limited and delayed Tc volatilization.« less

  14. 99m Tc-tazobactam, a novel infection imaging agent: Radiosynthesis, quality control, biodistribution, and infection imaging studies.

    PubMed

    Rasheed, Rashid; Naqvi, Syed Ali Raza; Gillani, Syed Jawad Hussain; Zahoor, Ameer Fawad; Jielani, Asif; Saeed, Nidda

    2017-05-15

    The radiolabeled drug 99m Tc-tazobactam ( 99m Tc-TZB) was developed and assessed as an infection imaging agent in Pseudomonas aeruginosa and Salmonella enterica infection-induced animal models by comparing with inflammation induced animal models. Radiosynthesis of 99m Tc-TZB was assessed while changing ligand concentration, reducing agent concentration, pH, and reaction time while keeping radioactivity constant (~370 MBq). Percent labeling of the resulting complex was measured using paper chromatography and instant thin layer chromatography. The analysis of the 99m Tc-TZB complex indicated >95% labeling yield and electrophoresis revealed complex is neutral in nature. The biodistribution study also showed predominantly renal excretion; however liver, stomach, and intestine also showed slight tracer agent uptake. The agent significantly accumulated in Pseudomonas aeruginosa and Salmonella enterica infection induced tissues 3.58 ± 0.26% and 2.43 ± 0.42% respectively at 1 hour postinjection. The inflamed tissue failed to uptake noticeable activity at 1 hour time point. The scintigraphic study results were found in accordance with biodistribution pattern. On the basis of our preliminary results, the newly developed 99m Tc-TZB can be used to diagnose bacterial infection and to discriminate between infected and inflamed tissues. Copyright © 2017 John Wiley & Sons, Ltd.

  15. Influence of time delay on the estimated lung shunt fraction on 99mTc-labeled MAA scintigraphy for 90Y microsphere treatment planning.

    PubMed

    De Gersem, Ruth; Maleux, Geert; Vanbilloen, Hubert; Baete, Kristof; Verslype, Chris; Haustermans, Karin; Verbruggen, Alfons; Van Cutsem, Eric; Deroose, Christophe Michel

    2013-12-01

    90Y-microspheres therapy is used to treat selected patients with primary or metastatic liver tumors in a safe and effective way. As a preparation for 90Y-microspheres treatment, a 99mTc-macroaggregated albumin (99mTc-MAA) simulation procedure is essential to evaluate particle shunting to the lung or gastrointestinal tract. We investigated the effect of interval between injection of 99mTc-MAA and time of scanning on the lung shunt fraction (LSF). In 4 patients with secondary hepatic malignancies who underwent repeated whole-body scintigraphy up to 5 hours after injection of 99mTc-MAA, a marked change in LSF was observed. It appears that tracer degradation leads to an important overestimation of LSF at later time points. An overestimation of LSF can lead to dose reduction or canceling of the planned 90Y-microspheres treatment. It is concluded that the interval between injection and scanning should be kept as short as possible.

  16. Direct production of 99mTc using a small medical cyclotron

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lapi, Suzanne

    This project describes an investigation towards the production of 99mTc with a small medical cyclotron. This endeavor addresses the current urgent problem of availability of 99mTc due to the ongoing production reactor failures and the upcoming Canadian reactor shut down. Currently, 99mTc is produced via nuclear fission using highly enriched uranium which is a concern due to nuclear proliferation risks. In addition to this, the United States is dependent solely on currently unreliable foreign sources of this important medical isotope. Clearly, a need exists to probe alternative production routes of 99mTc. In the first year, this project measured cross-sections andmore » production yields of potential pathways to 99mTc and associated radionuclidic impurities produced via these pathways using a small 15 MeV medical cyclotron. During the second and third years target systems for the production of 99mTc via the most promising reaction routes were developed and separation techniques for the isolation of 99mTc from the irradiated target material will be investigated. Systems for the recycling of the enriched target isotopes as well as automated target processing systems were examined in years four and five. This project has the potential to alleviate some of the current crisis in the medical community by developing a technique to produce 99mTc on location at a university hospital. This technology will be applicable at many other sites in the United States as many other similar, low energy (<20 MeV) cyclotrons (currently used for a few hours per day for the production of [ 18F]fluorodeoxyglucose) are available for production of 99mTc though this method, thus leading to job creation and preservation.« less

  17. Randomized, single-blind, factorial design study of the interaction of food and time on intestinal activity in 99mTc-tetrofosmin stress myocardial perfusion scintigraphy.

    PubMed

    Lyngholm, Ann Marie; Pedersen, Begitte H; Petersen, Lars J

    2008-09-01

    Intestinal activity at the inferior myocardial wall represents an issue for assessment of myocardial perfusion imaging (MPI) with 99mTc-labelled tracers. The aim of this study was to investigate the effect of time and food on upper abdominal activity in 99mTc-tetrofosmin MPI. The study population consisted of 152 consecutive patients referred for routine MPI. All patients underwent 2-day stress-rest 99mTc-tetrofosmin single-photon emission computed tomography MPI. Before stress testing, patients were randomized in a factorial design to four different regimens. Group A: early scan (image acquisition initiated within 15 min after injection of the tracer) and no food; group B: early scan and food (two pieces of white bread with butter and a minimum of 450 ml of water); group C: late scan (image acquisition 30-60 min after injection of the tracer) and no food; and group D: late and scan with food. Patients underwent standard bicycle exercise or pharmacological stress test. The degree of upper abdominal activity was evaluated by trained observers blinded to the randomization code. The primary endpoint was the proportion of accepted scans in the intention-to-treat population in stress MPI. The results showed statistical significant impact on both time and food on upper abdominal activity. The primary endpoint showed that the acceptance rate improved from 55% in group A to 100% success rate in group D. An early scan reduced the acceptance rate by 30% versus a late scan [hazard ratio 0.70, 95% confidence interval 0.58-0.84; P<0.0001], whereas the addition of food improved the success rate versus no food by 27% (hazard ratio 1.27, 95% confidence interval 1.07-1.51; P=0.006). No significant interaction between food and time was observed. An analysis of accepted scans according to the actual scan time and food consumption confirmed the findings of the intention-to-treat analysis. In addition, similar findings were seen in 116 of 152 patients with a rest MPI (success rate of

  18. Pixelized Measurement of (99m)Tc-HDP Micro Particles Formed in Gamma Correction Phantom Pinhole Scan: a Reference Study.

    PubMed

    Jung, Joo-Young; Cheon, Gi Jeong; Lee, Yun-Sang; Ha, Seunggyun; Chae, Mi-Hye; Chung, Yong-An; Yoon, Do Kyun; Bahk, Yong-Whee

    2016-09-01

    Currently, traumatic bone diseases are diagnosed by assessing the micro (99m)Tc-hydroxymethylene diphosphonate (HDP) uptake in injured trabeculae with ongoing osteoneogenesis demonstrated by gamma correction pinhole scan (GCPS). However, the mathematic size quantification of micro-uptake is not yet available. We designed and performed this phantom-based study to set up an in-vitro model of the mathematical calculation of micro-uptake by the pixelized measurement. The micro (99m)Tc-HDP deposits used in this study were spontaneously formed both in a large standard flood and small house-made dish phantoms. The processing was as follows: first, phantoms were flooded with distilled water and (99m)Tc-HDP was therein injected to induce micro (99m)Tc-HDP deposition; second, the deposits were scanned using parallel-hole and pinhole collimator to generally survey (99m)Tc-HDP deposition pattern; and third, the scans underwent gamma correction (GC) to discern individual deposits for size measurement. In original naïve scans, tracer distribution was simply nebulous in appearance and, hence, could not be measured. Impressively, however, GCPS could discern individual micro deposits so that they were calculated by pixelized measurement. Phantoms naturally formed micro (99m)Tc-HDP deposits that are analogous to (99m)Tc-HDP uptake on in-vivo bone scan. The smallest one we measured was 0.414 mm. Flooded phantoms and therein injected (99m)Tc-HDP form nebulous micro (99m)Tc-HDP deposits that are rendered discernible by GCPB and precisely calculable using pixelized measurement. This method can be used for precise quantitative and qualitative diagnosis of bone and joint diseases at the trabecular level.

  19. Efficiency gains in tracer identification for nuclear imaging: can in vivo LC-MS/MS evaluation of small molecules screen for successful PET tracers?

    PubMed

    Joshi, Elizabeth M; Need, Anne; Schaus, John; Chen, Zhaogen; Benesh, Dana; Mitch, Charles; Morton, Stuart; Raub, Thomas J; Phebus, Lee; Barth, Vanessa

    2014-12-17

    Positron emission tomography (PET) imaging has become a useful noninvasive technique to explore molecular biology within living systems; however, the utility of this method is limited by the availability of suitable radiotracers to probe specific targets and disease biology. Methods to identify potential areas of improvement in the ability to predict small molecule performance as tracers prior to radiolabeling would speed the discovery of novel tracers. In this retrospective analysis, we characterized the brain penetration or peak SUV (standardized uptake value), binding potential (BP), and brain exposure kinetics across a series of known, nonradiolabeled PET ligands using in vivo LC-MS/MS (liquid chromatography coupled to mass spectrometry) and correlated these parameters with the reported PET ligand performance in nonhuman primates and humans available in the literature. The PET tracers studied included those reported to label G protein-coupled receptors (GPCRs), intracellular enzymes, and transporters. Additionally, data for each tracer was obtained from a mouse brain uptake assay (MBUA), previously published, where blood-brain barrier (BBB) penetration and clearance parameters were assessed and compared against similar data collected on a broad compound set of central nervous system (CNS) therapeutic compounds. The BP and SUV identified via nonradiolabeled LC-MS/MS, while different from the published values observed in the literature PET tracer data, allowed for an identification of initial criteria values we sought to facilitate increased potential for success from our early discovery screening paradigm. Our analysis showed that successful, as well as novel, clinical PET tracers exhibited BP of greater than 1.5 and peak SUVs greater than approximately 150% at 5 min post dose in rodents. The brain kinetics appeared similar between both techniques despite differences in tracer dose, suggesting linearity across these dose ranges. The assessment of tracers in a

  20. Applying tracer techniques to determine recharge rate, groundwater age and travel times in Permo-Triassic sandstones.

    NASA Astrophysics Data System (ADS)

    Butcher, Andrew; Gallagher, Alexander; Darling, W. George; Gooddy, Daren; Burke, Sean

    2010-05-01

    The Eden Valley in East Cumbria is underlain by Permo-Triassic sandstone, the major aquifer in Northwest England. Rising nitrate trends in some boreholes has prompted collaborative research into flow systems and timescales in the area. The use of slurry and artificial fertilisers following agricultural intensification during the 1980s is believed to be responsible for the rise in nitrate concentrations. The broad aim of this research is to enable prediction of future nitrate concentrations at abstraction boreholes and in groundwater discharge to surface water. The approach taken has been to study groundwater processes along a 4km transect (approximating a groundwater flowline) in order to estimate groundwater travel timescales through the sandstone and thin superficial Till . A combination of porewater sampling during borehole coring, discrete interval sampling using a borehole packer system, geophysical logging and imaging were employed to develop physical and hydrochemical profiles. Separate tracer techniques were used to estimate recharge rates at different parts of the transect. Tracers used were: deuterium and bromide through Till, nitrate, chloride and tritium through the unsaturated zone and CFCs and SF6 within the saturated zone. Tracer profiles in Till demonstrated a correspondence between Till thickness, type of cultivation and recharge rate. In the thick unsaturated zone of the sandstone they suggested relatively rapid groundwater recharge rates. Key fractures or fracture zones in the saturated sandstone were identified and sampled. The hydrochemistry (particularly nitrate) of samples from discrete intervals in the profiles exhibited a remarkably good relationship with the proportion of modern water (and year of recharge) for example, the age of groundwater increasing to c. 1950 towards the bottom of a 90m borehole. This work demonstrates that the combination of discrete sampling and dating of groundwater is a powerful tool in characterising groundwater

  1. Two peptide receptor ligands (99m)Tc-EDDA/HYNIC-Tyr(3)-octreotide and (99m)Tc-EDDA/HYNIC-(D)Glu-octagastrin for scintigraphy of medullary thyroid carcinoma.

    PubMed

    Kosowicz, Jerzy; Mikołajczak, Renata; Czepczyński, Rafał; Ziemnicka, Katarzyna; Gryczyńska, Maria; Sowiński, Jerzy

    2007-10-01

    Somatostatin and gastrin receptors are overexpressed in medullary thyroid carcinoma (MTC) cells; hence, both of them are potential targets for peptide receptor scintigraphy and radiotherapy. Therefore, the aim of our study was to assess the clinical value of two technetium-99m-labeled peptides, a new gastrin analog, the EDDA/HYNIC-(D)Glu-octagastrin and a somatostatin analog, EDDA/HYNIC-Tyr(3)-octreotide (EDDA/HYNIC-TOC) for scintigraphy in patients with MTC to detect recurrences and metastases and select patients for peptide receptor radiotherapy. Thirty (30) patients, 20 females and 10 males, 22-83 years of age (mean, 52.7) with the diagnosis of MTC in different stages of the disease (preoperative, postsurgery, remission, recurrence, or metastatic disease) were included in this study. Before surgery, in all patients serum calcitonin concentrations were elevated. The diagnosis of MTC was confirmed in all cases by histopathology of the removed tumor and immunohistochemical staining giving positive reactions for calcitonin and chromogranin A. Imaging studies using (99m)Tc-EDDA/HYNIC-TOC and a new minigastrin analog, (99m)Tc-EDDA/HYNIC-(D)Glu-octagastrin, were performed in each patient and the results compared with each other and with other imaging methods. Scans of the whole body, head, neck, and chest were performed 2 and 4 hours after injections of the tracer, 500-600 MBq in each case, using a double-head Varicam (Elscint, Israel) gamma camera. (99m)Tc-EDDA/HYNIC-TOC detected somatostatin receptor-positive lesions in 20 patients with MTC, whereas (99m)Tc-EDDA/HYNIC-(D)Glu-octagastrin displayed gastrin receptors in 11 patients. In 9 cases, the scans were positive in both methods, although in 2 cases different pathologic foci were visualized. In 12 cases, only (99m)Tc-EDDA/HYNIC-TOC scintigraphy was positive, whereas in 3 other cases only (99m)Tc-EDDA/HYNIC-(D)Glu-octagastrin revealed pathologic lesions. Scintigraphy using (99m)Tc-HYNIC-TOC permits the visualization

  2. Partitioning and interfacial tracers for differentiating NAPL entrapment configuration: column-scale investigation.

    PubMed

    Dai, D; Barranco, F T; Illangasekare, T H

    2001-12-15

    Research on the use of partitioning and interfacial tracers has led to the development of techniques for estimating subsurface NAPL amount and NAPL-water interfacial area. Although these techniques have been utilized with some success at field sites, current application is limited largely to NAPL at residual saturation, such as for the case of post-remediation settings where mobile NAPL has been removed through product recovery. The goal of this study was to fundamentally evaluate partitioning and interfacial tracer behavior in controlled column-scale test cells for a range of entrapment configurations varying in NAPL saturation, with the results serving as a determinant of technique efficacy (and design protocol) for use with complexly distributed NAPLs, possibly at high saturation, in heterogeneous aquifers. Representative end members of the range of entrapment configurations observed under conditions of natural heterogeneity (an occurrence with residual NAPL saturation [discontinuous blobs] and an occurrence with high NAPL saturation [continuous free-phase LNAPL lens]) were evaluated. Study results indicated accurate prediction (using measured tracer retardation and equilibrium-based computational techniques) of NAPL amount and NAPL-water interfacial area for the case of residual NAPL saturation. For the high-saturation LNAPL lens, results indicated that NAPL-water interfacial area, but not NAPL amount (underpredicted by 35%), can be reasonably determined using conventional computation techniques. Underprediction of NAPL amount lead to an erroneous prediction of NAPL distribution, as indicated by the NAPL morphology index. In light of these results, careful consideration should be given to technique design and critical assumptions before applying equilibrium-based partitioning tracer methodology to settings where NAPLs are complexly entrapped, such as in naturally heterogeneous subsurface formations.

  3. Tracer tomography: design concepts and field experiments using heat as a tracer.

    PubMed

    Doro, Kennedy O; Cirpka, Olaf A; Leven, Carsten

    2015-04-01

    Numerical and laboratory studies have provided evidence that combining hydraulic tomography with tomographic tracer tests could improve the estimation of hydraulic conductivity compared with using hydraulic data alone. Field demonstrations, however, have been lacking so far, which we attribute to experimental difficulties. In this study, we present a conceptual design and experimental applications of tracer tomography at the field scale using heat as a tracer. In our experimental design, we improve active heat tracer testing by minimizing possible effects of heat losses, buoyancy, viscosity, and changing boundary conditions. We also utilize a cost-effective approach of measuring temperature changes in situ at high resolution. We apply the presented method to the 8 m thick heterogeneous, sandy gravel, alluvial aquifer at the Lauswiesen Hydrogeological Research Site in Tübingen, Germany. Results of our tomographic heat-tracer experiments are in line with earlier work on characterizing the aquifer at the test site. We demonstrate from the experimental perspective that tracer tomography is applicable and suitable at the field scale using heat as a tracer. The experimental results also demonstrate the potential of heat-tracer tomography as a cost-effective means for characterizing aquifer heterogeneity. © 2014, National Ground Water Association.

  4. Development of a Hybrid Tracer for SPECT and Optical Imaging of Bacterial Infections.

    PubMed

    Welling, Mick M; Bunschoten, Anton; Kuil, Joeri; Nelissen, Rob G H H; Beekman, Freek J; Buckle, Tessa; van Leeuwen, Fijs W B

    2015-05-20

    In trauma and orthopedic surgery, infection of implants has a major impact on the outcome for patients. Infections may develop either during the initial implantation or during the lifetime of an implant. Both infections, as well as aseptic loosening of the implant, are reasons for revision of the implants. Therefore, discrimination between aseptic-mechanical-loosening and septic-bacterial-loosening of implants is critical during selection of a patient-tailored treatment policy. Specific detection and visualization of infections is a challenge because it is difficult to discriminate infections from inflammation. An imaging tracer that facilitates bacterial identification in a pre- and intraoperative setting may aid the workup for patients suspicious of bacterial infections. In this study we evaluated an antimicrobial peptide conjugated to a hybrid label, which contains both a radioisotope and a fluorescent dye. After synthesis of DTPA-Cy5-UBI29-41 and-when necessary-radiolabeling with (111)In (yield 96.3 ± 2.7%), in vitro binding to various bacterial strains was evaluated using radioactivity counting and confocal fluorescence microscopy. Intramuscular bacterial infections (S. aureus or K. pneumoniae) were also visualized in vivo using a combined nuclear and fluorescence imaging system. The indium-111 was chosen as label as it has a well-defined coordination chemistry, and in pilot studies labeling DTPA-Cy5-UBI29-41 with technetium-99m, we encountered damage to the Cy5 dye after the reduction with SnCl2. As a reference, we used the validated tracer (99m)Tc-UBI29-41. Fast renal excretion of (111)In-DTPA-Cy5-UBI29-41 was observed. Target to nontarget (T/NT) ratios were highest at 2 h post injection: radioactivity counting yielded T/NT ratios of 2.82 ± 0.32 for S. aureus and 2.37 ± 0.05 for K. pneumoniae. Comparable T/NT ratios with fluorescence imaging of 2.38 ± 0.09 for S. aureus and 3.55 ± 0.31 for K. pneumoniae were calculated. Ex vivo confocal microscopy of

  5. Synthesis and evaluation of a (99m)Tc-MAMA-propyl-thymidine complex as a potential probe for in vivo visualization of tumor cell proliferation with SPECT.

    PubMed

    Celen, Sofie; de Groot, Tjibbe; Balzarini, Jan; Vunckx, Kathleen; Terwinghe, Christelle; Vermaelen, Peter; Van Berckelaer, Lizette; Vanbilloen, Hubert; Nuyts, Johan; Mortelmans, Luc; Verbruggen, Alfons; Bormans, Guy

    2007-04-01

    Cytosolic thymidine kinase (TK1) catalyzes phosphorylation of thymidine to its monophosphate. TK1 activity is closely related with DNA synthesis, and thymidine analogs derivatized with bulky carboranylalkyl groups at the N-3 position were reported to be good substrates for TK1. Accordingly, we have synthesized (99m)Tc-MAMA-propyl-thymidine and evaluated it as a potential tumor tracer. The bis(S-trityl)-protected MAMA-propyl-thymidine precursor (3-N-[S-trityl-2-mercaptoethyl]-N-[N'-(S-trityl-2-mercaptoethyl)amidoacetyl]-aminopropyl-thymidine) was prepared in three steps, and its structure was confirmed with (1)H NMR and mass spectrometry. Deprotection of the thiols and labeling with (99m)Tc were done in a two-step, one-pot procedure, yielding (99m)Tc-MAMA-propyl-thymidine, which was analyzed with high-performance liquid chromatography, radio-LC-MS analysis (ESI+) and electrophoresis, and its log P was determined. The biodistribution in normal mice was evaluated, and its biodistribution in a radiation-induced fibrosarcoma (RIF) tumor mouse was compared with that of 3'-deoxy-3'-[(18)F] fluorothymidine [(18)F]FLT. (99m)Tc-MAMA-propyl-thymidine was obtained with a radiochemical yield of 70%. Electrophoresis indicated that the complex is uncharged, and its log P was 1.0. The molecular ion mass of the Tc complex was 589 Da, which is compatible with the hypothesized N(2)S(2)-oxotechnetium structure. Tissue distribution showed fast clearance from plasma primarily by the hepatobiliary pathway. Whole-body planar imaging after injection of (99m)Tc-MAMA-propyl-thymidine in an RIF tumor-bearing mouse showed high uptake in the liver and the intestines. No uptake was observed in the tumor, in contrast to the clear uptake observed for [(18)F] FLT visualized with muPET. Although it has been reported that TK1 accepts large substituents at the N-3 position of the thymine ring, the results of this study show that (99m)Tc-MAMA-propyl-thymidine cannot be used as a single photon emission

  6. Rugged Low-Resistance Contacts To High-Tc Superconductors

    NASA Technical Reports Server (NTRS)

    Caton, Randall; Selim, Raouf; Byvik, Charles E.; Buoncristiani, A. Martin

    1992-01-01

    Newly developed technique involving use of gold makes possible to fabricate low-resistance contacts with rugged connections to high-Tc superconductors. Gold diffused into specimen of superconducting material by melting gold beads onto surface of specimen, making strong mechanical contacts. Shear strength of gold bead contacts greater than epoxy or silver paste. Practical use in high-current-carrying applications of new high-Tc materials, including superconducting magnets, long-wavelength sensors, electrical ground planes at low temperatures, and efficient transmission of power.

  7. Quantitative Visualization of Dynamic Tracer Transportation in the Extracellular Space of Deep Brain Regions Using Tracer-Based Magnetic Resonance Imaging.

    PubMed

    Hou, Jin; Wang, Wei; Quan, Xianyue; Liang, Wen; Li, Zhiming; Chen, Deji; Han, Hongbin

    2017-09-03

    BACKGROUND This study assessed an innovative tracer-based magnetic resonance imaging (MRI) system to visualize the dynamic transportation of tracers in regions of deep brain extracellular space (ECS) and to measure transportation ability and ECS structure. MATERIAL AND METHODS Gadolinium-diethylene triamine pentaacetic acid (Gd-DTPA) was the chosen tracer and was injected into the caudate nucleus and thalamus. Real-time dynamic transportation of Gd-DTPA in ECS was observed and the results were verified by laser scanning confocal microscopy. Using Transwell assay across the blood-brain barrier, a modified diffusion equation was further simplified. Effective diffusion coefficient D* and tortuosity λ were calculated. Immunohistochemical staining and Western blot analysis were used to investigate the extracellular matrix contributing to ECS structure. RESULTS Tracers injected into the caudate nucleus were transported to the ipsilateral frontal and temporal cortices away from the injection points, while both of them injected into the thalamus were only distributed on site. Although the caudate nucleus was closely adjacent to the thalamus, tracer transportation between partitions was not observed. In addition, D* and the λ showed statistically significant differences between partitions. ECS was shown to be a physiologically partitioned system, and its division is characterized by the unique distribution territory and transportation ability of substances located in it. Versican and Tenascin R are possible contributors to the tortuosity of ECS. CONCLUSIONS Tracer-based MRI will improve our understanding of the brain microenvironment, improve the techniques for local delivery of drugs, and highlight brain tissue engineering fields in the future.

  8. Small Column Testing of Superlig 639 for Removal of 99Tc from Hanford Tank Waste Envelope C (Tank 241-AN-107)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DL Blanchard; DE Kurath; BM Rapko

    The current BNFL Inc. flow sheet for pretreating Hanford High-Level tank wastes includes the use of Superlig(reg.sign)639 (SL-639) in a dual column system for removing technetium-99 ({sup 99}Tc) from the aqueous fraction of the waste. This sorbent material has been developed and supplied by IBC Advanced Technologies, Inc., American Fork, UT. This report documents the results of testing the SL-639 sorbent with diluted waste [Na{sup +}] {approx} 5 M from Tank 241-AN-107 (an Envelope C waste, abbreviated AN-107) at Battelle Northwest Laboratories (BNW). The equilibrium behavior was assessed with batch contacts between the sorbent and the waste. Two AN-107 samplesmore » were used: (1) an archived sample from previous testing and (2) a more recent sample collected specifically for BNFL. A portion of the archive sample and all of the BNFL sample were treated to remove Sr-90 and transuranic elements (TRU). All samples had also been Cs decontaminated by ion exchange (IX), and were spiked with a technetium-95m ({sup 95m}Tc) pertechnetate tracer, {sup 95m}TcO{sub 4}{sup -}.The TcO{sub 4}{sup -} and total Tc K{sub d} values, assumed equal to the {sup 95m}Tc and {sup 99}Tc K{sub d}'s, respectively, are shown in Table S1. Values are averages of duplicates, which showed significant scatter. The total Tc K{sub d} for the BNFL sample is much lower than the TcO{sub 4}{sup -}, indicating that a large fraction of the {sup 99}Tc is not pertechnetate.« less

  9. Relative distance between tracers as a measure of diffusivity within moving aggregates

    NASA Astrophysics Data System (ADS)

    Pönisch, Wolfram; Zaburdaev, Vasily

    2018-02-01

    Tracking of particles, be it a passive tracer or an actively moving bacterium in the growing bacterial colony, is a powerful technique to probe the physical properties of the environment of the particles. One of the most common measures of particle motion driven by fluctuations and random forces is its diffusivity, which is routinely obtained by measuring the mean squared displacement of the particles. However, often the tracer particles may be moving in a domain or an aggregate which itself experiences some regular or random motion and thus masks the diffusivity of tracers. Here we provide a method for assessing the diffusivity of tracer particles within mobile aggregates by measuring the so-called mean squared relative distance (MSRD) between two tracers. We provide analytical expressions for both the ensemble and time averaged MSRD allowing for direct identification of diffusivities from experimental data.

  10. Measurement of discharge using tracers

    USGS Publications Warehouse

    Kilpatrick, Frederick A.; Cobb, Ernest D.

    1984-01-01

    The development of fluorescent dyes and fluorometers that can measure these dyes at very low concentrations has made dye-dilution methods practical for measuring discharge. These methods are particularly useful for determining discharge under certain flow conditions that are unfavorable for current meter measurements. These include small streams, canals, and pipes where:Turbulence is excessive for current meter measurement but conducive to good mixing.Moving rocks and debris are damaging to any instruments placed in the flow.Cross-sectional areas or velocities are indeterminant or changing.There are some unsteady flows such as exist with storm-runoff events on small streams.The flow is physically inaccessible or unsafe.From a practical standpoint, such measurements are limited primarily to small streams due to excessively long channel mixing lengths required of larger streams. Very good accuracy can be obtained provided:Adequate mixing length and time are allowed.Careful field and laboratory techniques are employed.Dye losses are not significant.This manual describes the slug-injection and constant-rate injection methods of performing tracer-dilution measurements. Emphasis is on the use of fluorescent dyes as tracers and the equipment, field methods, and Laboratory procedures for performing such measurements. The tracer-velocity method is also briefly discussed.

  11. Global Visualization in Water using AnodizedAluminum PressureSensitive Paint and Dissolved Oxygen as Tracer

    NASA Astrophysics Data System (ADS)

    Ozaki, Tatsuya; Ishikawa, Hitoshi; Sakaue, Hirotaka

    2009-11-01

    We have developed anodized-aluminum pressuresensitive paint (AA-PSP) for flow visualization in water using dissolved oxygen as a tracer. Developed AA-PSP is characterized using water calibration setup by controlling a dissolved oxygen concentration. It is shown that the developed AA-PSP gives 4.0 percent change in luminescence per 1 mg/l of oxygen concentration. This AA-PSP is applied to visualize flows in a water tunnel. Oxygen concentrations of the water tunnel and the dissolved oxygen are 9.5 mg/l and 20 mg/l, respectively. We can capture horseshoe vortices over the base of 10 mm cylinder by using this technique at Reynolds number of 1000 and a water speed of 100 mm/s, respectively. Unlike conventional tracers such as ink, milk, and fluorescent dyes, this visualization technique gives flow information on the AA-PSP coated surface without integrating flows between the AA-PSP and an optical detector. Because of using dissolved oxygen as a tracer, it holds the material properties of testing water except for the amount of oxygen. The tracer does not interfere with optical measurements and it does not contaminate the testing water. A conventional visualization technique using milk as a tracer is also employed for comparison.

  12. PARTITIONING INTERWELL TRACER TEST FOR NAPL SOURCE CHARACTERIZATION: A GENERAL OVERVIEW

    EPA Science Inventory

    Innovative and nondestructive characterization techniques have been developed to locate and quantify nonaqueous phase liquids (NAPLs) in the vadose and saturated zones in the subsurface environment. One such technique is the partitioning interwell tracer test (PITT). The PITT i...

  13. Synthesis, characterization and biological evaluation of a novel "3 + 1" mixed ligand 99mTc complex having an aliphatic thiol as coligand.

    PubMed

    Rey, A; Papadopoulos, M; Leon, E; Mallo, L; Pirmettis, Y; Manta, E; Raptopoulou, C; Chiotellis, E; Leon, A

    2001-03-01

    A novel "3 + 1" mixed ligand 99mTc complex with N,N-bis(2-mercaptoethyl)-N'N'-diethyl-ethilenediamine as ligand and 1-octanethiol as coligand was prepared and evaluated as potential brain radiopharmaceutical. Preparation at tracer level was accomplished by substitution, using 99mTc-glucoheptonate as precursor and a coligand/ligand ratio of 5. Under these conditions the labeling yield was over 80% and a major product with radiochemical purity >80% was isolated by HPLC methods and used for biological evaluation. Chemical characterization at carrier level was developed using the corresponding rhenium and 99gTc complexes. Results were consistent with the expected "3 + 1" structure and X-ray diffraction study demonstrated that the complex adopted a distorted trigonal bipyramidal geometry. All sulphur atoms underwent ionization leading to the formation of a neutral compound. Biodistribution in mice demonstrated early brain uptake, fast blood clearance and excretion through hepatobiliary system. Although brain/blood ratio increased significantly with time, this novel 99mTc complex did not exhibit ideal properties as brain perfusion radiopharmaceutical since brain uptake was too low.

  14. A historical perspective on radioisotopic tracers in metabolism and biochemistry.

    PubMed

    Lappin, Graham

    2015-01-01

    Radioisotopes are used routinely in the modern laboratory to trace and quantify a myriad of biochemical processes. The technique has a captivating history peppered with groundbreaking science and with more than its share of Nobel Prizes. The discovery of radioactivity at the end of the 19th century paved the way to understanding atomic structure and quickly led to the use of radioisotopes to trace the fate of molecules as they flowed through complex organic life. The 1940s saw the first radiotracer studies using homemade instrumentation and analytical techniques such as paper chromatography. This article follows the history of radioisotopic tracers from meager beginnings, through to the most recent applications. The author hopes that those researchers involved in radioisotopic tracer studies today will pause to remember the origins of the technique and those who pioneered this fascinating science.

  15. Wear Measurement of Highly Cross-linked UHMWPE using a 7Be Tracer Implantation Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wimmer, Markus A.; Laurent, Michael P.; Dwivedi, Yasha

    2013-01-01

    The very low wear rates achieved with the current highly cross-linked ultrahigh molecular weight polyethylenes (UHMWPE) used in joint prostheses have proven to be difficult to measure accurately by gravimetry. Tracer methods are there- fore being explored. The purpose of this study was to perform a proof-of-concept experiment on the use of the radioactive tracer beryllium-7 (7Be) for the determination of in vitro wear in a highly cross-linked orthopedic UHMWPE. Three cross-linked and four conventional UHMWPE pins made from compression- molded GUR 1050, were activated with 109 to 1010 7Be nuclei using a new implantation setup that produced a homogenousmore » distribution of implanted nuclei up to 8.5 lm below the surface. The pins were tested for wear in a six-station pin-on-flat appara- tus for up to 7.1 million cycles (178 km). A Germanium gamma detector was employed to determine activity loss of the UHMWPE pins at preset intervals during the wear test. The wear of the cross-linked UHMWPE pins was readily detected and esti- mated to be 17 6 3 lg per million cycles. The conventional-to- cross-linked ratio of the wear rates was 13.1 6 0.8, in the expected range for these materials. Oxidative degradation dam- age from implantation was negligible; however, a weak depend- ence of wear on implantation dose was observed limiting the number of radioactive tracer atoms that can be introduced. Future applications of this tracer technology may include the analysis of location-specific wear, such as loss of material in the post or backside of a tibial insert.« less

  16. A volatile tracer-assisted headspace analytical technique for determining the swelling capacity of superabsorbent polymers.

    PubMed

    Zhang, Shu-Xin; Jiang, Ran; Chai, Xin-Sheng

    2017-09-01

    This paper reports on a new method for the determination of swelling capacity of superabsorbent polymers by a volatile tracer-assisted headspace gas chromatography (HS-GC). Toluene was used as a tracer and added to the solution for polymers swelling test. Based on the differences of the tracer partitioned between the vapor and hydrogel phase before and after the polymer's swelling capacity, a transition point (corresponding to the material swelling capacity) can be observed when plotting the GC signal of toluene vs. the ratio of solution added to polymers. The present method has good precision (RSD<2.1%) and good accuracy, in which the relative deference between the data measured by the HS-GC method and the reference method were within 8.0%. The present method is very suitable to be used for testing the swelling capacity of polymers at the elevated temperatures. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Simulation of soluble waste transport and buildup in surface waters using tracers

    USGS Publications Warehouse

    Kilpatrick, F.A.

    1993-01-01

    Soluble tracers can be used to simulate the transport and dispersion of soluble wastes that might have been introduced or are planned for introduction into surface waters. Measured tracer-response curves produced from the injection of a known quantity of soluble tracer can be used in conjunction with the superposition principle to simulate potential waste buildup in streams, lakes, and estuaries. Such information is particularly valuable to environmental and water-resource planners in determining the effects of proposed waste discharges. The theory, techniques, analysis, and presentation of results of tracer-waste simulation tests in rivers, lakes, and estuaries are described. This manual builds on other manuals dealing with dye tracing by emphasizing the expanded use of data from time-of-travel studies.

  18. Simulation of soluble waste transport and buildup in surface waters using tracers

    USGS Publications Warehouse

    Kilpatrick, Frederick A.

    1992-01-01

    Soluble tracers can be used to simulate the transport and dispersion of soluble wastes that might have been introduced or are planned for introduction into surface waters. Measured tracer-response curves produced from the injection of a known quantity of soluble tracer can be used in conjunction with the superposition principle to simulate potential waste buildup in streams, lakes, and estuaries. Such information is particularly valuable to environmental and water-resource planners in determining the effects of proposed waste discharges.The theory, techniques, analysis, and presentation of results of tracer-waste simulation tests in rivers, lakes, and estuaries are described. This manual builds on other manuals on dye tracing with emphasis on the expanded use of time-of-travel type data.

  19. Altered [99mTc]Tc-MDP biodistribution from neutron activation sourced 99Mo.

    PubMed

    Demeter, Sandor; Szweda, Roman; Patterson, Judy; Grigoryan, Marine

    2018-01-01

    Given potential worldwide shortages of fission sourced 99 Mo/ 99m Tc medical isotopes there is increasing interest in alternate production strategies. A neutron activated 99 Mo source was utilized in a single center phase III open label study comparing 99m Tc, as 99m Tc Methylene Diphosphonate ([ 99m Tc]Tc-MDP), obtained from solvent generator separation of neutron activation produced 99 Mo, versus nuclear reactor produced 99 Mo (e.g., fission sourced) in oncology patients for which an [ 99m Tc]Tc-MDP bone scan would normally have been indicated. Despite the investigational [ 99m Tc]Tc-MDP passing all standard, and above standard of care, quality assurance tests, which would normally be sufficient to allow human administration, there was altered biodistribution which could lead to erroneous clinical interpretation. The cause of the altered biodistribution remains unknown and requires further research.

  20. Overview of SIMS-Based Experimental Studies of Tracer Diffusion in Solids and Application to Mg Self-Diffusion

    DOE PAGES

    Kulkarni, Nagraj S.; Bruce Warmack, Robert J.; Radhakrishnan, Bala; ...

    2014-09-23

    Tracer diffusivities provide the most fundamental information on diffusion in materials and are the foundation of robust diffusion databases. Compared to traditional radiotracer techniques that utilize radioactive isotopes, the secondary ion mass spectrometry (SIMS) based thin-film technique for tracer diffusion is based on the use of enriched stable isotopes that can be accurately profiled using SIMS. Experimental procedures & techniques that are utilized for the measurement of tracer diffusion coefficients are presented for pure magnesium, which presents some unique challenges due to the ease of oxidation. The development of a modified Shewmon-Rhines diffusion capsule for annealing Mg and an ultra-highmore » vacuum (UHV) system for sputter deposition of Mg isotopes are discussed. Optimized conditions for accurate SIMS depth profiling in polycrystalline Mg are provided. An automated procedure for the correction of heat-up and cool-down times during tracer diffusion annealing is discussed. The non-linear fitting of a SIMS depth profile data using the thin film Gaussian solution to obtain the tracer diffusivity along with the background tracer concentration and tracer film thickness is discussed. An Arrhenius fit of the Mg self-diffusion data obtained using the low-temperature SIMS measurements from this study and the high-temperature radiotracer measurements of Shewmon and Rhines (1954) was found to be a good representation of both types of diffusion data that cover a broad range of temperatures between 250 - 627° C (523 900 K).« less

  1. Dynamic dual-tracer MRI-guided fluorescence tomography to quantify receptor density in vivo

    PubMed Central

    Davis, Scott C.; Samkoe, Kimberley S.; Tichauer, Kenneth M.; Sexton, Kristian J.; Gunn, Jason R.; Deharvengt, Sophie J.; Hasan, Tayyaba; Pogue, Brian W.

    2013-01-01

    The up-regulation of cell surface receptors has become a central focus in personalized cancer treatment; however, because of the complex nature of contrast agent pharmacokinetics in tumor tissue, methods to quantify receptor binding in vivo remain elusive. Here, we present a dual-tracer optical technique for noninvasive estimation of specific receptor binding in cancer. A multispectral MRI-coupled fluorescence molecular tomography system was used to image the uptake kinetics of two fluorescent tracers injected simultaneously, one tracer targeted to the receptor of interest and the other tracer a nontargeted reference. These dynamic tracer data were then fit to a dual-tracer compartmental model to estimate the density of receptors available for binding in the tissue. Applying this approach to mice with deep-seated gliomas that overexpress the EGF receptor produced an estimate of available receptor density of 2.3 ± 0.5 nM (n = 5), consistent with values estimated in comparative invasive imaging and ex vivo studies. PMID:23671066

  2. Partitioning Tracer Test for Detection, Estimation, and Remediation Performance Assessment of Subsurface Nonaqueous Phase Liquids

    NASA Astrophysics Data System (ADS)

    Jin, Minquan; Delshad, Mojdeh; Dwarakanath, Varadarajan; McKinney, Daene C.; Pope, Gary A.; Sepehrnoori, Kamy; Tilburg, Charles E.; Jackson, Richard E.

    1995-05-01

    In this paper we present a partitioning interwell tracer test (PITT) technique for the detection, estimation, and remediation performance assessment of the subsurface contaminated by nonaqueous phase liquids (NAPLs). We demonstrate the effectiveness of this technique by examples of experimental and simulation results. The experimental results are from partitioning tracer experiments in columns packed with Ottawa sand. Both the method of moments and inverse modeling techniques for estimating NAPL saturation in the sand packs are demonstrated. In the simulation examples we use UTCHEM, a comprehensive three-dimensional, chemical flood compositional simulator developed at the University of Texas, to simulate a hypothetical two-dimensional aquifer with properties similar to the Borden site contaminated by tetrachloroethylene (PCE), and we show how partitioning interwell tracer tests can be used to estimate the amount of PCE contaminant before remedial action and as the remediation process proceeds. Tracer tests results from different stages of remediation are compared to determine the quantity of PCE removed and the amount remaining. Both the experimental (small-scale) and simulation (large-scale) results demonstrate that PITT can be used as an innovative and effective technique to detect and estimate the amount of residual NAPL and for remediation performance assessment in subsurface formations.

  3. Partitioning tracer test for detection, estimation, and remediation performance assessment of subsurface nonaqueous phase liquids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jin, M.; Delshad, M.; Dwarakanath, V.

    1995-05-01

    In this paper we present a partitioning interwell tracer test (PITT) technique for the detection, estimation, and remediation performance assessment of the subsurface contaminated by nonaqueous phase liquids (NAPLs). We demonstrate the effectiveness of this technique by examples of experimental and simulation results. The experimental results are from partitioning tracer experiments in columns packed with Ottawa sand. Both the method of moments and inverse modeling techniques for estimating NAPL saturation in the sand packs are demonstrated. In the simulation examples we use UTCHEM, a comprehensive three-dimensional, chemical flood compositional simulator developed at the University of Texas, to simulate a hypotheticalmore » two-dimensional aquifer with properties similar to the Borden site contaminated by tetrachloroethylene (PCE), and we show how partitioning interwell tracer tests can be used to estimate the amount of PCE contaminant before remedial action and as the remediation process proceeds. Tracer test results from different stages of remediation are compared to determine the quantity of PCE removed and the amount remaining. Both the experimental (small-scale) and simulation (large-scale) results demonstrate that PITT can be used as an innovative and effective technique to detect and estimate the amount of residual NAPL and for remediation performance assessment in subsurface formations. 43 refs., 10 figs., 1 tab.« less

  4. Chemical Tracer Methods: Chapter 7

    USGS Publications Warehouse

    Healy, Richard W.

    2017-01-01

    Tracers have a wide variety of uses in hydrologic studies: providing quantitative or qualitative estimates of recharge, identifying sources of recharge, providing information on velocities and travel times of water movement, assessing the importance of preferential flow paths, providing information on hydrodynamic dispersion, and providing data for calibration of water flow and solute-transport models (Walker, 1998; Cook and Herczeg, 2000; Scanlon et al., 2002b). Tracers generally are ions, isotopes, or gases that move with water and that can be detected in the atmosphere, in surface waters, and in the subsurface. Heat also is transported by water; therefore, temperatures can be used to trace water movement. This chapter focuses on the use of chemical and isotopic tracers in the subsurface to estimate recharge. Tracer use in surface-water studies to determine groundwater discharge to streams is addressed in Chapter 4; the use of temperature as a tracer is described in Chapter 8.Following the nomenclature of Scanlon et al. (2002b), tracers are grouped into three categories: natural environmental tracers, historical tracers, and applied tracers. Natural environmental tracers are those that are transported to or created within the atmosphere under natural processes; these tracers are carried to the Earth’s surface as wet or dry atmospheric deposition. The most commonly used natural environmental tracer is chloride (Cl) (Allison and Hughes, 1978). Ocean water, through the process of evaporation, is the primary source of atmospheric Cl. Other tracers in this category include chlorine-36 (36Cl) and tritium (3H); these two isotopes are produced naturally in the Earth’s atmosphere; however, there are additional anthropogenic sources of them.

  5. Preservation of commonly applied fluorescent tracers in complex water samples

    NASA Astrophysics Data System (ADS)

    Cao, Viet; Schaffer, Mario; Jin, Yulan; Licha, Tobias

    2017-06-01

    Water sample preservation and pre-treatment are important steps for achieving accurate and reproductive results from tracer tests. However, this is particularly challenging for complex water mixtures prior to fluorescence analysis. In this study, the interference of iron and calcium precipitation with nine commonly applied conservative tracers, uranine, eosin, 1-naphthalene sulfonate, 1,5-naphthalene disulfonate, 2,6-naphthalene disulfonate, 4-amino-1-naphthalene sulfonate, 6-hydroxy-2-naphthalene sulfonate, 1,3,6-naphthalene trisulfonate, and 1,3,6,8-pyrene tetrasulfonate, was investigated in batch experiments. In general, the observed results are influenced by precipitates. A technique consisting of pH adjustment and centrifugation is described for preserving samples and avoiding the impact of these precipitates on the tracer test results.

  6. (99m)Tc-labeled SWL specific peptide for targeting EphA2 receptor.

    PubMed

    Liu, Yu; Lan, Xiaoli; Wu, Tao; Lang, Juntao; Jin, Xueyan; Sun, Xun; Wen, Qiong; An, Rui

    2014-07-01

    EphA2, one member of the Eph receptor family, is widely expressed in multiple aggressive cancers. SWL, a small peptide identified by phage display, has high binding affinity to EphA2, suggesting that it could be exploited for targeted molecular imaging. Therefore, a novel peptide-based probe, (99m)Tc-HYNIC-SWL, was developed and its potential to specifically target EphA2-positive tumors was investigated. The SWL peptide was labeled with hydrazinonicotinic acid (HYNIC), followed by (99m)Tc labeling. Immunofluorescence staining was carried out to detect the expression of EphA2 in A549 lung cancer cells and OCM-1 melanoma cells. Saturation binding experiments were performed by incubating A549 cells with increasing concentrations of radiolabeled peptide in vitro. To test the probe in vivo, nude mice bearing either A549 or OCM-1 derived tumors were established, injected with (99m)Tc-HYNIC-SWL, and subjected to SPECT imaging. Mice injected with excess unlabeled SWL were used as a specific control. Ex vivo γ-counting of dissected tissues from the mice was also performed to evaluate biodistribution. Immunofluorescence staining showed that A549 cells intensively expressed EphA2, while OCM-1 cells had little expression. (99m)Tc-HYNIC-SWL displayed high binding affinity with A549 cells (KD=2.6±0.7nM). From the SPECT images and the results of the biodistribution study, significantly higher uptake of the tracer was seen in A549 tumors (1.44±0.12 %ID/g) than in OCM-1 tumors (0.43±0.20 %ID/g) at 1h after injection. Pre-injection with excess unlabeled peptide in A549-bearing nude mice, significantly reduced tumor uptake of the radiolabeled probe (0.58±0.20 %ID/g) was seen. These data suggest that (99m)Tc-HYNIC-SWL specifically targets EphA2 in tumors. The expression of EphA2 can be noninvasively investigated using (99m)Tc-HYNIC-SWL by SPECT imaging. The in vitro and in vivo characteristics of (99m)Tc-HYNIC-SWL make it a promising probe for EphA2-positive tumor imaging

  7. Exploring Hydrofluorocarbons as Groundwater Age Tracers (Invited)

    NASA Astrophysics Data System (ADS)

    Haase, K. B.; Busenberg, E.; Plummer, L. N.; Casile, G.; Sanford, W. E.

    2013-12-01

    refrigerant introduced in the 1940's, with atmospheric mixing ratios increasing through the 1990s to the present value of ≈230 pptv. HFC-134a is typically is used as a chlorine-free replacement for CFC-12, finding use in air-condition systems and as an inert aerosol blowing agent, with a mixing ratio that has increased from <1 in 1994 to ≈75 pptv at present (2013). Their unique atmospheric histories and chemistry compared to CFCs makes these compounds interesting age tracer candidates, particularly in situations where multiple tracers enhance interpretive value. For instance, inclusion in lumped parameter mixing models and in situations where SF6 or the CFCs are present in elevated concentrations from non-atmospheric sources such that they cannot be used for dating purposes. Analysis of standards, air equilibrated water, and blanks suggests the GC-AED system is capable of detecting concentrations ≈200 fM (HCFC-22) and ≈100 fM (HFC-134a), corresponding to piston flow ages of 54 and 18 yr, respectively, with a typical uncertainty of ≈1 yr. Preliminary comparisons with CFC and SF6 analyses show general agreement between the techniques (within a few years), and ongoing intercomparison studies will be discussed.

  8. Slew-rate dependence of tracer magnetization response in magnetic particle imaging.

    PubMed

    Shah, Saqlain A; Ferguson, R M; Krishnan, K M

    2014-10-28

    Magnetic Particle Imaging (MPI) is a new biomedical imaging technique that produces real-time, high-resolution tomographic images of superparamagnetic iron oxide nanoparticle tracers. Currently, 25 kHz and 20 mT/μ 0 excitation fields are common in MPI, but lower field amplitudes may be necessary for patient safety in future designs. Here, we address fundamental questions about MPI tracer magnetization dynamics and predict tracer performance in future scanners that employ new combinations of excitation field amplitude ( H o ) and frequency ( ω ). Using an optimized, monodisperse MPI tracer, we studied how several combinations of drive field frequencies and amplitudes affect the tracer's response, using Magnetic Particle Spectrometry and AC hysteresis, for drive field conditions at 15.5, 26, and 40.2 kHz, with field amplitudes ranging from 7 to 52 mT/μ 0 . For both fluid and immobilized nanoparticle samples, we determined that magnetic response was dominated by Néel reversal. Furthermore, we observed that the peak slew-rate ( ωH o ) determined the tracer magnetic response. Smaller amplitudes provided correspondingly smaller field of view, sometimes resulting in excitation of minor hysteresis loops. Changing the drive field conditions but keeping the peak slew-rate constant kept the tracer response almost the same. Higher peak slew-rates led to reduced maximum signal intensity and greater coercivity in the tracer response. Our experimental results were in reasonable agreement with Stoner-Wohlfarth model based theories.

  9. 99mTc-EDDA/HYNIC-TOC: a new 99mTc-labelled radiopharmaceutical for imaging somatostatin receptor-positive tumours; first clinical results and intra-patient comparison with 111In-labelled octreotide derivatives.

    PubMed

    Decristoforo, C; Mather, S J; Cholewinski, W; Donnemiller, E; Riccabona, G; Moncayo, R

    2000-09-01

    [111In-diethylene triamine penta-acetic acid-D-Phe1]-octreotide (DTPA-octreotide) scintigraphy has gained widespread acceptance as a diagnostic clinical procedure in oncology for imaging somatostatin receptor-positive tumours. However, indium-111 as a radiolabel has several drawbacks, including limited availability, suboptimal gamma energy and high radiation burden to the patient. We have recently reported on the preclinical development of 99mTc-EDDA/HYNIC-TOC, a new octreotide derivative which showed promising results both in vitro and in vivo. We now report our initial clinical experiences with this new radiopharmaceutical in ten oncological patients. The clinical diagnoses were: carcinoid syndrome (n=5), thyroid cancer (n=3), pancreatic cancer (n=1) and pituitary tumour (n=1). The biodistribution and kinetics of 99mTc-EDDA/HYNIC-TOC were compared with those of 111In-DTPA-octreotide in six cases, and with those of 111In-DOTA-TOC in five cases. With the new tracer tumours were imaged within 15 min after injection and showed the highest target/non-target ratios 4 h after injection. Tumour uptake persisted up to 20 h p.i. The rate of blood clearance was similar to that of 111In-DTPA-octreotide but faster than that of 111In-DOTA-TOC, while urinary excretion was lower compared with the 111In derivatives. Semi-quantitative region of interest analysis showed that 99mTc-EDDA/HYNIC-TOC produced higher tumour/organ (target/non-target) ratios than the 111In derivatives, especially in relation to heart and muscle. Significantly more lesions could be detected in 99mTc images. We conclude that 99mTcEDDA/HYNIC-TOC shows better imaging properties for the identification of somatostatin receptor-positive tumour sites than currently available 111In-labelled octreotide derivatives.

  10. Tracers for monitoring the activity of sodium/glucose cotransporters in health and disease

    DOEpatents

    Wright, Ernest M; Barrio, Jorge R; Hirayama, Bruce A; Kepe, Vladimir

    2014-09-30

    Radiolabeled tracers for sodium/glucose cotransporters (SGLTs), their synthesis, and their use are provided. The tracers are methyl or ethyl pyranosides having an equatorial hydroxyl group at carbon-2 and a C 1 preferred conformation, radiolabeled with .sup.18F, .sup.123I, or .sup.124I, or free hexoses radiolabeled with .sup.18F, .sup.123I, or .sup.124. Also provided are in vivo and in vitro techniques for using these and other tracers as analytical and diagnostic tools to study glucose transport, in health and disease, and to evaluate therapeutic interventions.

  11. Measurement of discharge using tracers

    USGS Publications Warehouse

    Kilpatrick, F.A.; Cobb, Ernest D.

    1985-01-01

    The development of fluorescent dyes and fluorometers that can measure these dyes at very low concentrations has made dye-dilution methods practical for measuring discharge. These methods are particularly useful for determining discharge under certain flow conditions that are unfavorable for current meter measurements. These include small streams, canals, and pipes where 1. Turbulence is excessive for current-meter measurement but conducive to good mixing. 2. Moving rocks and debris may damage instruments placed in the flow. 3. Cross-sectional areas or velocities are indeterminate or changing. 4. The flow is unsteady, such as the flow that exists with storm-runoff events on small streams and urban storm-sewer systems. 5. The flow is physically inaccessible or unsafe. From a practical standpoint, such methods are limited primarily to small streams, because of the excessively long channel-mixing lengths required for larger streams. Very good accuracy can be obtained provided that 1. Adequate mixing length and time are allowed. 2. Careful field and laboratory techniques are used. 3. Dye losses are not significant. This manual describes the slug-injection and constant-rate injection methods of performing tracer-dilution measurements. Emphasis is on the use of fluorescent dyes as tracers and the equipment, field methods, and laboratory procedures for performing such measurements. The tracer-velocity method is also briefly discussed.

  12. (99m)Tc-EDDA/HYNIC-octreotate - a new radiotracer for detection and staging of NET: a case of metastatic duodenal carcinoid.

    PubMed

    Hubalewska-Dydejczyk, Alicja; Szybiński, Piotr; Fröss-Baron, Katarzyna; Mikolajczak, Renata; Huszno, Bohdan; Sowa-Staszczak, Anna

    2005-01-01

    Somatostatin receptor scintigraphy (SRS) has become a routine imaging method for the diagnostics of neuroendocrine tumours (NET). (99m)Tc-EDDA/HYNIC-octreotate (Polatom, Poland) is a new radiotracer with high affinity for SSTR2 and similar physiological biodistribution to (111)In-Octreoscan. We present a case of a 47-year-old man with disseminated duodenal carcinoid. The patient had been operated due to the tumour mass detected in pancreatic head area. Histopathology revealed carcinoid of the duodenal wall with local lymph node and liver metastases. The patient was qualified for chemotherapy stopped due to severe leucopenia. (99m)Tc EDDA/HYNIC-octreotate scintigraphy was performed for staging and to determine SSTR status of the tumour before planned 90Y-DOTATATE therapy. The multiple metastatic lesions were detected all over the body. The high quality images with high target/non target ratio were obtained. (99m)Tc-MDP scintigraphy confirmed multiple bone metastases. On the basis of SRS result the patient was qualified for 90Y-DOTA-TATE therapy. In conclusion, (99m)Tc EDDA/HYNIC-octreotate can be regarded as a promising tracer for staging and to determine SSTR status of NET.

  13. Flow visualization in superfluid helium-4 using He2 molecular tracers

    NASA Astrophysics Data System (ADS)

    Guo, Wei

    Flow visualization in superfluid helium is challenging, yet crucial for attaining a detailed understanding of quantum turbulence. Two problems have impeded progress: finding and introducing suitable tracers that are small yet visible; and unambiguous interpretation of the tracer motion. We show that metastable He2 triplet molecules are outstanding tracers compared with other particles used in helium. These molecular tracers have small size and relatively simple behavior in superfluid helium: they follow the normal fluid motion at above 1 K and will bind to quantized vortex lines below about 0.6 K. A laser-induced fluorescence technique has been developed for imaging the He2 tracers. We will present our recent experimental work on studying the normal-fluid motion by tracking thin lines of He2 tracers created via femtosecond laser-field ionization in helium. We will also discuss a newly launched experiment on visualizing vortex lines in a magnetically levitated superfluid helium drop by imaging the He2 tracers trapped on the vortex cores. This experiment will enable unprecedented insight into the behavior of a rotating superfluid drop and will untangle several key issues in quantum turbulence research. We acknowledge the support from the National Science Foundation under Grant No. DMR-1507386 and the US Department of Energy under Grant No. DE-FG02 96ER40952.

  14. Joint Use of ERT, Tracer, and Numerical Techniques to Image Preferential Flow Paths in a Fractured Granite Aquifer

    NASA Astrophysics Data System (ADS)

    Sanaga, S.; Vijay, S.; Kbvn, P.; Peddinti, S. R.; P S L, S.

    2017-12-01

    Fractured geologic media poses formidable challenges to hydrogeologists due of the strenuous mapping of fracture-matrix system and quantification of flow and transport processes. In this research, we demonstrated the efficacy of tracer-ERT studies coupled with numerical simulations to delineate preferential flow paths in a fractured granite aquifer of Deccan traps in India. A series of natural gradient saline tracer experiments were conducted from a depth window of 18 to 22 m in an injection well located inside the IIT Hyderabad campus. Tracer migration was monitored in a time-lapse mode using two cross-sectional surface ERT profiles placed in the direction of flow gradient. Dynamic changes in sub-surface electrical properties inferred via resistivity anomalies were used to highlight preferential flow paths of the study area. ERT-derived tracer breakthrough curves were in agreement with geochemical sample measurements (R2=0.74). Fracture geometry and hydraulic properties derived from ERT and pumping tests were then used to evaluate two mathematical conceptualizations that are relevant to fractured aquifers. Results of numerical analysis conclude that a dual continuum model that combines matrix and fracture systems through a flow exchange term has outperformed equivalent continuum model in reproducing tracer concentrations at the monitoring wells (evident by decrease in RMSE from 199 mg/l to 65 mg/l). A sensitivity analysis of the model parameters reveals that spatial variability in hydraulic conductivity, local-scale dispersion, and flow exchange at fracture-matrix interface have a profound effect on model simulations. Keywords: saline tracer, ERT, fractured granite, groundwater, preferential flow, numerical simulation

  15. The field campaigns of the European Tracer Experiment (ETEX). overview and results

    NASA Astrophysics Data System (ADS)

    Nodop, K.; Connolly, R.; Girardi, F.

    As part of the European Tracer Experiment (ETEX) two successful atmospheric experiments were carried out in October and November, 1994. Perfluorocarbon (PFC) tracers were released into the atmosphere in Monterfil, Brittany, and air samples were taken at 168 stations in 17 European countries for 72 h after the release. Upper air tracer measurements were made from three aircraft. During the first experiment a westerly air flow transported the tracer plume north-eastwards across Europe. During the second release the flow was eastwards. The results from the ground sampling network allowed the determination of the cloud evolution as far as Sweden, Poland and Bulgaria. This demonstrated that the PFT technique can be successfully applied in long-range tracer experiments up to 2000 km. Typical background concentrations of the tracer used are around 5-7 fl ℓ -1 in ambient air. Concentrations in the plume ranged from 10 to above 200 fl/ℓ -1. The tracer release characteristics, the tracer concentrations at the ground and in upper air, the routine and additional meteorological observations at the ground level and in upper air, trajectories derived from constant-level balloons and the meteorological input fields for long-range transport models are assembled in the ETEX database. The ETEX database is accessible via the Internet. Here, an overview is given of the design of the experiment, the methods used and the data obtained.

  16. Imaging, biodistribution and in vitro study of smart 99mTc-PAMAM G4 dendrimer as novel nano-complex.

    PubMed

    Narmani, Asghar; Yavari, Kamal; Mohammadnejad, Javad

    2017-11-01

    Overexpression of folic acid receptor in various human tumors cells makes it as good candidate for targeting delivery of chemotherapeutic and radiopharmaceutical agents. In this research, FA used for functionalization of PEG modified PAMAM G4 dendrimer as a smart delivery of 5-FU and 99m Tc for the breast carcinoma in order to chemotherapeutic and imaging goals. One aim of this research was assess the FA-mediated cell viability assay of PEG-PAMAM G4-FA-5FU- 99m Tc and in vitro uptake of PEG-PAMAM G4-FA- 99m Tc as the novel nano-complex determined on C2Cl2 (normal cell) and MCF-7 (breast cancer cell) cell lines. Other main goals were studied. Morover, an investigation in to in vivo imaging and biodistribution was carried out via a novel radio tracer by which tumor accumulation and site were obviously detected. The targeted tumor images taken by tail intravenous injection demonstrated that nano-complex can be smartly used in imaging study of the clinical practices. Also, the biodistribution of this nano-complex was investigated and the organ predestination of 99m Tc labeled nano-complex (%ID/g) was ascertained. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Trypanosoma cruzi DTU TcII presents higher blood parasitism than DTU TcI in an experimental model of mixed infection.

    PubMed

    Sales-Campos, Helioswilton; Kappel, Henrique Borges; Andrade, Cristiane Pontes; Lima, Tiago Pereira; de Castilho, Alessandra; Giraldo, Luis Eduardo Ramirez; Lages-Silva, Eliane

    2015-09-01

    Trypanosoma cruzi (Tc), the causative agent of Chagas disease, affects millions of people worldwide. One of the major characteristics of T. cruzi is related to its heterogeneity due to the variability of its biological properties, parasite growth rates, infectivity, tissue tropism, morbidity and virulence among different isolates observed during experimental or human infection. Moreover, presence of mixed infections in the same host in endemic areas is a matter of study due to its impact on clinical manifestations and disease progression. In this study, we evaluated the biological behavior of two Tc I strains AQ1-7 (AQ) and MUTUM (MT) and one Tc II strain (JG) during the acute phase of infection, in unique and mixed infections. A patent blood parasitism was detected only in mice inoculated with JG strain . In addition blood parasitism parameters (peak and average blood parasitism) were positively associated when JG and AQ strains were combined. In contrast, a negative association was observed in the JG+MUTUM group. The predominance of TcII strain over TcI strains was highlighted using the LSSP-PCR technique, which was performed in samples from hemoculture. Thus, this study showed important biological differences between different T. cruzi strains and discrete typing units (DTUs) in acute phase. Finally, we observed that blood parasitism during early period of infection seems to be more related to DTU than to a specific strain.

  18. Characterization of two-phase flow regimes in horizontal tubes using 81mKr tracer experiments.

    PubMed

    Oriol, Jean; Leclerc, Jean Pierre; Berne, Philippe; Gousseau, Georges; Jallut, Christian; Tochon, Patrice; Clement, Patrice

    2008-10-01

    The diagnosis of heat exchangers on duty with respect to flow mal-distributions needs the development of non-intrusive inlet-outlet experimental techniques in order to perform an online fault diagnosis. Tracer experiments are an example of such techniques. They can be applied to mono-phase heat exchangers but also to multi-phase ones. In this case, the tracer experiments are more difficult to perform. In order to check for the capabilities of tracer experiments to be used for the flow mal-distribution diagnosis in the case of multi-phase heat exchangers, we present here a preliminary study on the simplest possible system: two-phase flows in a horizontal tube. (81m)Kr is used as gas tracer and properly collimated NaI (TI) crystal scintillators as detectors. The specific shape of the tracer response allows two-phase flow regimes to be characterized. Signal analysis allows the estimation of the gas phase real average velocity and consequently of the liquid phase real average velocity as well as of the volumetric void fraction. These results are compared successfully to those obtained with liquid phase tracer experiments previously presented by Oriol et al. 2007. Characterization of the two-phase flow regimes and liquid dispersion in horizontal and vertical tubes using coloured tracer and no intrusive optical detector. Chem. Eng. Sci. 63(1), 24-34, as well as to those given by correlations from literature.

  19. Using a tracer technique to identify the extent of non-ideal flows in the continuous mixing of non-Newtonian fluids

    NASA Astrophysics Data System (ADS)

    Patel, D.; Ein-Mozaffari, F.; Mehrvar, M.

    2013-05-01

    The identification of non-ideal flows in a continuous-flow mixing of non-Newtonian fluids is a challenging task for various chemical industries: plastic manufacturing, water and wastewater treatment, and pulp and paper manufacturing. Non-ideal flows such as channelling, recirculation, and dead zones significantly affect the performance of continuous-flow mixing systems. Therefore, the main objective of this paper was to develop an identification protocol to measure non-ideal flows in the continuous-flow mixing system. The extent of non-ideal flows was quantified using a dynamic model that incorporated channelling, recirculation, and dead volume in the mixing vessel. To estimate the dynamic model parameters, the system was excited using a frequency-modulated random binary input by injecting the saline solution (as a tracer) into the fresh feed stream prior to being pumped into the mixing vessel. The injection of the tracer was controlled by a computer-controlled on-off solenoid valve. Using the trace technique, the extent of channelling and the effective mixed volume were successfully determined and used as mixing quality criteria. Such identification procedures can be applied at various areas of chemical engineering in order to improve the mixing quality.

  20. [Renal excretion of methylene-diphosphate-technium-99m. Preliminary observations].

    PubMed

    Vattimo, A; Martini, G

    1983-11-30

    The purpose of this study is to elucidate the mechanism of the renal excretion of 99mTc-MDP in man. We compared the renal clearance of 99mTc-MDP and 51Cr-EDTA (glomerular filtration rate agent). Since the 99mTc-MDP is bound to the plasma protein, the free fraction was calculated by dialysis. The clearances were obtained by single-injection technique. The plasma disappearance of the tracers was resolved into three exponential functions and area was calculated. The clearance was calculated by dividing the amount of the tracers excreted during the first four hours and the plasma area. In this study no difference was found in the clearance of the two agents. These findings suggest that the renal excretion of diphosphonate is related to the glomerular filtration rate.

  1. High Tc superconducting films from metallo-organic precursors

    NASA Astrophysics Data System (ADS)

    Davison, W. W.; Shyu, S. G.; Buchanan, R. C.

    High Tc superconducting films of heavy metal soaps (derived from carboxylic acid precursors) have been prepared on Si and other substrates. The precursors were synthesized and mixed in appropriate molar ratios to form the high Tc compound YBa2Cu3O(7-x), using a high boiling point common solvent base. The precursor solution was deposited by a spin casting technique on the substrates. Film thicknesses of 0.1-1.0 micron were achieved after heat treatment at 550-850 C at not longer than 4 hours. Films were analyzed as to orientation, appropriate phase, interfacial reaction, and superconducting properties.

  2. Comparison of the radioactive and modified techniques for measurement of stream reaeration coefficients

    USGS Publications Warehouse

    Rathbun, R.E.; Grant, R. Stephen

    1978-01-01

    There are advantages and disadvantages to both the radioactive and modified tracer techniques. The main advantage of the radioactive technique is that the tracer gas is chemically inert; the main disadvantage is that a radioactive isotope of the gas must be used to obtain the necessary analytical sensitivity. The main advantage of the modified technique is that radioactive tracers are not necessary; the main disadvantage is that the hydrocarbon tracer gases may be subject to biological degradation and sorption losses. Results of this comparison study suggest that the modified technique is a promising alternative to the use of radioactive tracers.

  3. Slew-rate dependence of tracer magnetization response in magnetic particle imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shah, Saqlain A.; Krishnan, K. M., E-mail: kannanmk@uw.edu; Ferguson, R. M.

    2014-10-28

    Magnetic Particle Imaging (MPI) is a new biomedical imaging technique that produces real-time, high-resolution tomographic images of superparamagnetic iron oxide nanoparticle tracers. Currently, 25 kHz and 20 mT/μ{sub 0} excitation fields are common in MPI, but lower field amplitudes may be necessary for patient safety in future designs. Here, we address fundamental questions about MPI tracer magnetization dynamics and predict tracer performance in future scanners that employ new combinations of excitation field amplitude (H{sub o}) and frequency (ω). Using an optimized, monodisperse MPI tracer, we studied how several combinations of drive field frequencies and amplitudes affect the tracer's response, using Magnetic Particlemore » Spectrometry and AC hysteresis, for drive field conditions at 15.5, 26, and 40.2 kHz, with field amplitudes ranging from 7 to 52 mT/μ{sub 0}. For both fluid and immobilized nanoparticle samples, we determined that magnetic response was dominated by Néel reversal. Furthermore, we observed that the peak slew-rate (ωH{sub o}) determined the tracer magnetic response. Smaller amplitudes provided correspondingly smaller field of view, sometimes resulting in excitation of minor hysteresis loops. Changing the drive field conditions but keeping the peak slew-rate constant kept the tracer response almost the same. Higher peak slew-rates led to reduced maximum signal intensity and greater coercivity in the tracer response. Our experimental results were in reasonable agreement with Stoner-Wohlfarth model based theories.« less

  4. Application of zinc isotope tracer technology in tracing soil heavy metal pollution

    NASA Astrophysics Data System (ADS)

    Norbu, Namkha; Wang, Shuguang; Xu, Yan; Yang, Jianqiang; Liu, Qiang

    2017-08-01

    Recent years the soil heavy metal pollution has become increasingly serious, especially the zinc pollution. Due to the complexity of this problem, in order to prevent and treat the soil pollution, it's crucial to accurately and quickly find out the pollution sources and control them. With the development of stable isotope tracer technology, it's able to determine the composition of zinc isotope. Based on the theory of zinc isotope tracer technique, and by means of doing some latest domestic and overseas literature research about the zinc isotope multi-receiving cups of inductively coupled plasma mass spectrometer (MC-ICP-MS) testing technology, this paper summarized the latest research results about the pollution tracer of zinc isotope, and according to the deficiencies and existing problems of previous research, made outlooks of zinc isotope fractionation mechanism, repository establishment and tracer multiple solutions.

  5. Ultra-sensitive in-situ detection of near-infrared persistent luminescent tracer nanoagents in crude oil-water mixtures.

    PubMed

    Chuang, Yen-Jun; Liu, Feng; Wang, Wei; Kanj, Mazen Y; Poitzsch, Martin E; Pan, Zhengwei

    2016-06-15

    Current fluorescent nanoparticles-based tracer sensing techniques for oilfield applications suffer from insufficient sensitivity, with the tracer detection limit typically at the several hundred ppm level in untreated oil/water mixtures, which is mainly caused by the interference of the background fluorescence from the organic residues in crude oil under constant external excitation. Here we report the use of a persistent luminescence phenomenon, which enables an external excitation-free and thus background fluorescence-free measurement condition, for ultrahigh-sensitivity crude oil sensing. By using LiGa5O8:Cr(3+) near-infrared persistent luminescent nanoparticles as a tracer nanoagent, we achieved a tracer detection limit at the single-digit ppb level (down to 1 ppb concentration of nanoparticles) in high oil fraction (up to 65 wt.%) oil/water mixtures via a convenient, CCD camera-based imaging technique without any pretreatment or phase separation of the fluid samples. This detection limit is about four to five orders of magnitude lower than that obtained using conventional spectral methods. This study introduces a new type of tracer nanoagents and a new detection method for water tracer sensing in oil reservoir characterization and management.

  6. The impact trajectory of asteroid 2008 TC3

    NASA Astrophysics Data System (ADS)

    Farnocchia, Davide; Jenniskens, Peter; Robertson, Darrel K.; Chesley, Steven R.; Dimare, Linda; Chodas, Paul W.

    2017-09-01

    The impact of asteroid 2008 TC3 was an unprecedented event-the first ever predicted impact of a near-Earth object. When it was first detected about 20 h before impact, 2008 TC3 was still farther away than the Moon. Once it was recognized as an impactor and announced as such, 2008 TC3 began to receive considerable attention from astronomical observers. Using the unprecedented dataset of nearly 900 astrometric observations and the latest observation debiasing and weighting techniques, we estimate the precise trajectory of 2008 TC3 and its impact ground track. At the entry point into the atmosphere, the 3-σ formal uncertainty in predicted position is an ellipse only 1.4 km × 0.15 km in size. The locations of the many meteorites recovered from the desert floor mark the asteroid's actual ground track and provide a unique opportunity to validate trajectory models. We find that the second-order zonal harmonics of the Earth gravity field moves the ground track by more than 1 km and the location along the ground track by more than 2 km, while non-zonal and higher order harmonics change the impact prediction by less than 20 m. The contribution of atmospheric drag to the trajectory of 2008 TC3 is similar to the numerical integration error level, a few meters, down to an altitude of 50 km. Integrating forward to lower altitudes and ignoring the break-up of 2008 TC3, atmospheric drag causes an along-track deviation that can be as large as a few kilometers at sea level.

  7. Development of Tc(IV)-Incorporated Fe Minerals to Enhance 99Tc Retention in Glass Waste Form

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Um, Wooyong; Luksic, Steven A.; Wang, Guohui

    Iron minerals have been considered to be good hosts for Tc immobilization because the Tc(IV) ion substitutes for Fe(III) in the crystal structure of the Fe oxide due to similarities in (1) cation size [Tc(IV) = 78.5 pm ; Fe(III) = 69 or 78.5 pm], (2) metal-oxygen interatomic distance (Tc—O = 0.199 nm, Fe—O = 0.203 nm), (3) number of coordinating oxygen atoms (both 6-fold coordinated), and (4) the redox potential (Eh=ca. +20 mV at pH = 7) for a redox couple between Tc(VII)/Tc(IV) and Fe(III)/Fe(II). Magnetite, maghemite, and trevorite are iron oxide minerals and all belong to spinel mineralmore » group. Laboratory testing shows that Tc can be removed from aqueous waste solutions by a process of Tc reduction from Tc(VII) to Tc(IV) followed by co-precipitation with iron oxide minerals during recrystallization of Fe(OH)2(s) used as an initial solid precursor. X-ray absorption near edge structure (XANES) spectroscopy confirmed that Tc was in the +4 oxidation state in final Tc-Fe minerals. The Tc-incorporated Fe minerals were also tested for Tc retention in glass melts at different temperatures between 600 – 1,000 oC in a furnace. After being cooled in air, the solid glass specimens collected at different temperatures were analyzed for Tc oxidation state using XANES and Tc retention using liquid scintillation counting (LSC). Even though Tc(IV) started to reoxidize at 600 oC, Tc retention in the final glass specimen prepared with Tc-incorporated Fe mineral even at high temperatures was at least two times higher than glass prepared with KTcO4 salt. Higher Tc retention in glass is considered to result from limited and delayed Tc volatilization process due to Fe mineral encapsulation for Tc. Therefore, the results showing the presence of Tc(IV) in the Fe mineral structure indicate strong possibility to enhance Tc retention in borosilicate glass as well as to reduce the remediation costs at the Hanford Site.« less

  8. Combining tracer flux ratio methodology with low-flying aircraft measurements to estimate dairy farm CH4 emissions

    NASA Astrophysics Data System (ADS)

    Daube, C.; Conley, S.; Faloona, I. C.; Yacovitch, T. I.; Roscioli, J. R.; Morris, M.; Curry, J.; Arndt, C.; Herndon, S. C.

    2017-12-01

    Livestock activity, enteric fermentation of feed and anaerobic digestion of waste, contributes significantly to the methane budget of the United States (EPA, 2016). Studies question the reported magnitude of these methane sources (Miller et. al., 2013), calling for more detailed research of agricultural animals (Hristov, 2014). Tracer flux ratio is an attractive experimental method to bring to this problem because it does not rely on estimates of atmospheric dispersion. Collection of data occurred during one week at two dairy farms in central California (June, 2016). Each farm varied in size, layout, head count, and general operation. The tracer flux ratio method involves releasing ethane on-site with a known flow rate to serve as a tracer gas. Downwind mixed enhancements in ethane (from the tracer) and methane (from the dairy) were measured, and their ratio used to infer the unknown methane emission rate from the farm. An instrumented van drove transects downwind of each farm on public roads while tracer gases were released on-site, employing the tracer flux ratio methodology to assess simultaneous methane and tracer gas plumes. Flying circles around each farm, a small instrumented aircraft made measurements to perform a mass balance evaluation of methane gas. In the course of these two different methane quantification techniques, we were able to validate yet a third method: tracer flux ratio measured via aircraft. Ground-based tracer release rates were applied to the aircraft-observed methane-to-ethane ratios, yielding whole-site methane emission rates. Never before has the tracer flux ratio method been executed with aircraft measurements. Estimates from this new application closely resemble results from the standard ground-based technique to within their respective uncertainties. Incorporating this new dimension to the tracer flux ratio methodology provides additional context for local plume dynamics and validation of both ground and flight-based data.

  9. Dynamic dual-tracer PET reconstruction.

    PubMed

    Gao, Fei; Liu, Huafeng; Jian, Yiqiang; Shi, Pengcheng

    2009-01-01

    Although of important medical implications, simultaneous dual-tracer positron emission tomography reconstruction remains a challenging problem, primarily because the photon measurements from dual tracers are overlapped. In this paper, we propose a simultaneous dynamic dual-tracer reconstruction of tissue activity maps based on guidance from tracer kinetics. The dual-tracer reconstruction problem is formulated in a state-space representation, where parallel compartment models serve as continuous-time system equation describing the tracer kinetic processes of dual tracers, and the imaging data is expressed as discrete sampling of the system states in measurement equation. The image reconstruction problem has therefore become a state estimation problem in a continuous-discrete hybrid paradigm, and H infinity filtering is adopted as the estimation strategy. As H infinity filtering makes no assumptions on the system and measurement statistics, robust reconstruction results can be obtained for the dual-tracer PET imaging system where the statistical properties of measurement data and system uncertainty are not available a priori, even when there are disturbances in the kinetic parameters. Experimental results on digital phantoms, Monte Carlo simulations and physical phantoms have demonstrated the superior performance.

  10. In situ monitoring of tracer tests: how to distinguish tracer recovery from natural background

    NASA Astrophysics Data System (ADS)

    Bailly-Comte, V.; Durepaire, X.; Batiot-Guilhe, C.; Schnegg, P.-A.

    2018-03-01

    Hydrogeological tracer tests are primarily conducted with fluorescent tracers. Field fluorometers make it possible to monitor tracers at very low concentrations (<1 ppb) and at high frequency. However, changes in natural fluorescence at a site resulting from variations of dissolved and suspended inorganic and organic material may compromise the measurement of useful signals, thereby limiting the chances of identifying or quantifying the real tracer recovery. An elevated natural signal can mask small concentrations of the tracer while its variability can give the impression of a false recovery. This article shows how the use of a combination of several continuous measurements at different wavelengths allows a better extraction of the natural signal. Field multispectral fluorometers were installed at two Mediterranean karst outlets; both drain carbonate systems but have different environmental conditions. The fluorometers functioned over several hydrologic cycles, in periods affected or not by artificial tracers, making it possible to observe natural signal variations at these sites. The optical properties of this type of field fluorometer were used to calculate the spectral response of the different optics of the measuring probe. These responses, superimposed on three-dimensional excitation/emission matrices produced from laboratory fluorescence measurements, allowed an understanding of what the fluorometer sees under natural flow conditions. The result is an innovative method for correcting artificial tracer results. This type of correction makes it possible to fine-tune the effect of natural background variation on tracer recovery curves for a clear identification of the tracer presence and a more precise quantification of its recovery.

  11. Getters for Tc and I Removal from Liquid Waste

    NASA Astrophysics Data System (ADS)

    Qafoku, N. P.; Asmussen, M.; Lawter, A.; Neeway, J.; Smith, G.

    2015-12-01

    A cementitious waste form, Cast Stone, is being evaluated as a possible supplemental waste form for the low activity waste (LAW) at the Hanford Site, which contains significant amounts of radioactive 99Tc and 129I, as part of the tank waste cleanup mission. To improve the retention of Tc and/or I in Cast Stone, materials with a high affinity for Tc and/or I, termed "getters," can be added to decrease the rate of contaminant release and diffusivity, and improve Cast Stone performance. A series of kinetic batch sorption experiments was performed to determine the effectiveness of the getter materials. Several Tc getters [blast furnace slag, Sn (II) apatite, SnCl2, nanoporous Sn phosphate, KMS-2 (a potassium-metal-sulfide), and Sn(II) hydroxyapatite] and I getters [layered Bi hydroxide, natural argentite mineral, synthetic argentite, Ag-impregnated carbon, and Ag-exchanged zeolite] were tested in different solution media, 18.2 MΩ DI H2O and a caustic LAW waste simulant containing 6.5 M Na or 7.8 M Na. The experiments were conducted at room temperature in the presence or absence of air. Results indicated that most Tc getters (with the exception of KMS-2) performed better in the DI H2O solution than in the 6.5 and 7.8 M Na LAW simulant. In addition, Tc sequestration may be affected by the presence of other redox sensitive elements that were present in the LAW simulant, such as Cr. The Tc getter materials have been examined through various solid-state characterization techniques such as XRD, SEM/EDS, XANES and EXAFS which provided evidence for plausible mechanisms of aqueous Tc removal. The results indicated that the Tc precipitates differ depending on the getter material and that Tc(VII) is reduced to Tc(IV) in most of the getters but to a differing extents. For the I getters, Ag-exchanged zeolite and synthetic argentite were the most effective ones. The other I getters showed limited effectiveness for sorbing I under the high ionic strength and caustic

  12. Altimetric lagrangian advection to reconstruct Pacific Ocean fine scale surface tracer fields

    NASA Astrophysics Data System (ADS)

    Rogé, Marine; Morrow, Rosemary; Dencausse, Guillaume

    2015-04-01

    In past studies, lagrangian stirring of surface tracer fields by altimetric surface geostrophic currents has been performed in different mid to high-latitude regions, showing good results in reconstructing finer-scale tracer patterns. Here we apply the technique to three different regions in the eastern and western tropical Pacific, and in the subtropical southwest Pacific. Initial conditions are derived from weekly gridded temperature and salinity fields, based on hydrographic data and Argo. Validation of the improved fine-scale surface tracer fields is performed using satellite AMSRE SST data, and high-resolution ship thermosalinograph data. We test two kinds of lagrangian advection. The standard one-way advection is shown to introduce an increased tracer bias as the advection time increases. Indeed, since we only use passive stirring, a bias is introduced from the missing physics, such as air-sea fluxes or mixing. A second "backward-forward" advection technique is shown to reduce the seasonal bias, but more data is lost around coasts and islands, a strong handicap in the tropical Pacific with many small islands. In the subtropical Pacific Ocean, the mesoscale temperature and salinity fronts are well represented by the one-way advection over a 10-day advection time, including westward propagating features not apparent in the initial fields. In the tropics, the results are less clear. The validation is hampered by the complex vertical stratification, and the technique is limited by the lack of accurate surface currents for the stirring - the gridded altimetric fields poorly represent the meridional currents, and are not detecting the fast tropical instability waves, nor the wind-driven circulation. We suggest that the passive lateral stirring technique is efficient in regions with moderate the high mesoscale energy and correlated mesoscale surface temperature and surface height. In other regions, more complex dynamical processes may need to be included.

  13. Simultaneous measurement of ventilation using tracer gas techniques and VOC concentrations in homes, garages and vehicles.

    PubMed

    Batterman, Stuart; Jia, Chunrong; Hatzivasilis, Gina; Godwin, Chris

    2006-02-01

    Air exchange rates and interzonal flows are critical ventilation parameters that affect thermal comfort, air migration, and contaminant exposure in buildings and other environments. This paper presents the development of an updated approach to measure these parameters using perfluorocarbon tracer (PFT) gases, the constant injection rate method, and adsorbent-based sampling of PFT concentrations. The design of miniature PFT sources using hexafluorotoluene and octafluorobenzene tracers, and the development and validation of an analytical GC/MS method for these tracers are described. We show that simultaneous deployment of sources and passive samplers, which is logistically advantageous, will not cause significant errors over multiday measurement periods in building, or over shorter periods in rapidly ventilated spaces like vehicle cabins. Measurement of the tracers over periods of hours to a week may be accomplished using active or passive samplers, and low method detection limits (<0.025 microg m(-3)) and high precisions (<10%) are easily achieved. The method obtains the effective air exchange rate (AER), which is relevant to characterizing long-term exposures, especially when ventilation rates are time-varying. In addition to measuring the PFT tracers, concentrations of other volatile organic compounds (VOCs) are simultaneously determined. Pilot tests in three environments (residence, garage, and vehicle cabin) demonstrate the utility of the method. The 4 day effective AER in the house was 0.20 h(-1), the 4 day AER in the attached garage was 0.80 h(-1), and 16% of the ventilation in the house migrated from the garage. The 5 h AER in a vehicle traveling at 100 km h(-1) under a low-to-medium vent condition was 92 h(-1), and this represents the highest speed test found in the literature. The method is attractive in that it simultaneously determines AERs, interzonal flows, and VOC concentrations over long and representative test periods. These measurements are

  14. Direct Parametric Image Reconstruction in Reduced Parameter Space for Rapid Multi-Tracer PET Imaging.

    PubMed

    Cheng, Xiaoyin; Li, Zhoulei; Liu, Zhen; Navab, Nassir; Huang, Sung-Cheng; Keller, Ulrich; Ziegler, Sibylle; Shi, Kuangyu

    2015-02-12

    The separation of multiple PET tracers within an overlapping scan based on intrinsic differences of tracer pharmacokinetics is challenging, due to limited signal-to-noise ratio (SNR) of PET measurements and high complexity of fitting models. In this study, we developed a direct parametric image reconstruction (DPIR) method for estimating kinetic parameters and recovering single tracer information from rapid multi-tracer PET measurements. This is achieved by integrating a multi-tracer model in a reduced parameter space (RPS) into dynamic image reconstruction. This new RPS model is reformulated from an existing multi-tracer model and contains fewer parameters for kinetic fitting. Ordered-subsets expectation-maximization (OSEM) was employed to approximate log-likelihood function with respect to kinetic parameters. To incorporate the multi-tracer model, an iterative weighted nonlinear least square (WNLS) method was employed. The proposed multi-tracer DPIR (MTDPIR) algorithm was evaluated on dual-tracer PET simulations ([18F]FDG and [11C]MET) as well as on preclinical PET measurements ([18F]FLT and [18F]FDG). The performance of the proposed algorithm was compared to the indirect parameter estimation method with the original dual-tracer model. The respective contributions of the RPS technique and the DPIR method to the performance of the new algorithm were analyzed in detail. For the preclinical evaluation, the tracer separation results were compared with single [18F]FDG scans of the same subjects measured 2 days before the dual-tracer scan. The results of the simulation and preclinical studies demonstrate that the proposed MT-DPIR method can improve the separation of multiple tracers for PET image quantification and kinetic parameter estimations.

  15. Stable isotope tracers and exercise physiology: past, present and future.

    PubMed

    Wilkinson, Daniel J; Brook, Matthew S; Smith, Kenneth; Atherton, Philip J

    2017-05-01

    Stable isotope tracers have been invaluable assets in physiological research for over 80 years. The application of substrate-specific stable isotope tracers has permitted exquisite insight into amino acid, fatty-acid and carbohydrate metabolic regulation (i.e. incorporation, flux, and oxidation, in a tissue-specific and whole-body fashion) in health, disease and response to acute and chronic exercise. Yet, despite many breakthroughs, there are limitations to 'substrate-specific' stable isotope tracers, which limit physiological insight, e.g. the need for intravenous infusions and restriction to short-term studies (hours) in controlled laboratory settings. In recent years significant interest has developed in alternative stable isotope tracer techniques that overcome these limitations, in particular deuterium oxide (D 2 O or heavy water). The unique properties of this tracer mean that through oral administration, the turnover and flux through a number of different substrates (muscle proteins, lipids, glucose, DNA (satellite cells)) can be monitored simultaneously and flexibly (hours/weeks/months) without the need for restrictive experimental control. This makes it uniquely suited for the study of 'real world' human exercise physiology (amongst many other applications). Moreover, using D 2 O permits evaluation of turnover of plasma and muscle proteins (e.g. dynamic proteomics) in addition to metabolomics (e.g. fluxomics) to seek molecular underpinnings, e.g. of exercise adaptation. Here, we provide insight into the role of stable isotope tracers, from substrate-specific to novel D 2 O approaches, in facilitating our understanding of metabolism. Further novel potential applications of stable isotope tracers are also discussed in the context of integration with the snowballing field of 'omic' technologies. © 2016 The Authors. The Journal of Physiology © 2016 The Physiological Society.

  16. Glucagon-like peptide-1 receptor imaging with [Lys40(Ahx-HYNIC- 99mTc/EDDA)NH2]-exendin-4 for the detection of insulinoma.

    PubMed

    Sowa-Staszczak, Anna; Pach, Dorota; Mikołajczak, Renata; Mäcke, Helmut; Jabrocka-Hybel, Agata; Stefańska, Agnieszka; Tomaszuk, Monika; Janota, Barbara; Gilis-Januszewska, Aleksandra; Małecki, Maciej; Kamiński, Grzegorz; Kowalska, Aldona; Kulig, Jan; Matyja, Andrzej; Osuch, Czesław; Hubalewska-Dydejczyk, Alicja

    2013-04-01

    The objective of this article is to present a new method for the diagnosis of insulinoma with the use of [Lys(40)(Ahx-HYNIC-(99m)Tc/EDDA)NH2]-exendin-4. Studies were performed in 11 patients with negative results of all available non-isotopic diagnostic methods (8 with symptoms of insulinoma, 2 with malignant insulinoma and 1 with nesidioblastosis). In all patients glucagon-like peptide-1 (GLP-1) receptor imaging (whole-body and single photon emission computed tomography/CT examinations) after the injection of 740 MBq of the tracer was performed. Both sensitivity and specificity of GLP-1 receptor imaging were assessed to be 100 % in patients with benign insulinoma. In all eight cases with suspicion of insulinoma a focal uptake in the pancreas was found. In six patients surgical excision of the tumour was performed (type G1 tumours were confirmed histopathologically). In one patient surgical treatment is planned. One patient was disqualified from surgery. In one case with malignant insulinoma pathological accumulation of the tracer was found only in the region of local recurrence. The GLP-1 study was negative in the other malignant insulinoma patient. In one case with suspicion of nesidioblastosis, a focal accumulation of the tracer was observed and histopathology revealed coexistence of insulinoma and nesidioblastosis. [Lys(40)(Ahx-HYNIC-(99m)Tc/EDDA)NH2]-exendin-4 seems to be a promising diagnostic tool in the localization of small insulinoma tumours, but requires verification in a larger series of patients.

  17. PARTITIONING TRACERS FOR MEASURING RESIDUAL NAPL: FIELD-SCALE TEST RESULTS

    EPA Science Inventory

    The difficult task of locating and quantifying nonaqueous phase liquids (NAPLs) present in the vadose and saturated zones has prompted the development of innovative, nondestructive characterization techniques. The use of the interwell partitioning tracer's (IWPT) test, in which ...

  18. A line source tracer test - a better method for assessing high groundwater velocity

    NASA Astrophysics Data System (ADS)

    Magal, E.; Weisbrod, N.; Yakirevich, A.; Kurtzman, D.; Yechieli, Y.

    2009-12-01

    A line source injection is suggested as an effective method for assessing groundwater velocities and flow directions in subsurface characterized by high water fluxes. Modifying the common techniques of injecting a tracer into a well was necessary after frequently-used methods of natural and forced gradient tracer tests ended with no reliable information on the local groundwater flow. In a field experiment, tracers were injected into 8-m long line injection system constructed below the water table almost perpendicular to the assumed flow direction. The injection system was divided to four separate segments (each 2 m long) enabling the injection of four different tracers along the line source. An array of five boreholes located in an area of 10x10 m downstream was used for monitoring the tracers' transport. Two dye tracers (Uranine and Na Naphthionate) were injected in a long pulse of several hours into two of the injection pipe segments and two tracers (Rhenium oxide and Gd-DTPA) were instantaneously injected to the other two segments. The tracers were detected 0.7 to 2.3 hours after injection in four of the five observation wells, located 2.3 to 10 m from the injection system, respectively. Groundwater velocities were calculated directly from the tracers' arrival times and by fitting the observed breakthrough curves to simulations with one and two dimensions analytical solutions for conservative tracer transport. The groundwater velocity was determined to be ~100 m/d. The longitudinal dispersivity value, generated from fitting the tracer breakthrough curves, was in a range of 0.2-3m. The groundwater flow direction was derived based on the arrival of the tracers and was found to be consistent with the apparent direction of the hydraulic gradient. The hydraulic conductivity derived from the groundwater velocity was ~1200 m/d, which is in the upper range of gravel sediment.

  19. Use of a portable, automated, open-circuit gas quantification system and the sulfur hexafluoride tracer technique for measuring enteric methane emissions in Holstein cows fed ad libitum or restricted

    USDA-ARS?s Scientific Manuscript database

    The sulfur hexafluoride tracer technique (SF**6) is a commonly used method for measuring CH**4 enteric emissions in ruminants. Studies using SF**6 have shown large variation in CH**4 emissions data, inconsistencies in CH**4 emissions across studies, and potential methodological errors. Therefore, th...

  20. Journal: A Review of Some Tracer-Test Design Equations for Tracer-Mass Estimation and Sample Collection Frequency

    EPA Science Inventory

    Determination of necessary tracer mass, initial sample-collection time, and subsequent sample-collection frequency are the three most difficult aspects to estimate for a proposed tracer test prior to conducting the tracer test. To facilitate tracer-mass estimation, 33 mass-estima...

  1. Can Positron 2D-ACAR Resolve the Electronic Structure of HIGH-Tc Superconductors?

    NASA Astrophysics Data System (ADS)

    Chan, L. P.; Lynn, K. G.; Harshman, D. R.

    We examine the ability of the positron Two-Dimensional Angular Correlation Annihilation Radiation (2D-ACAR) technique to resolve the electronic structures of high-Tc cuprate superconductors. Following a short description of the technique, discussions of the theoretical assumptions, data analysis and experimental considerations, in relation to the high-Tc superconductors, are given. We briefly review recent 2D-ACAR experiments on YBa2Cu3O7-x, Bi2Sr2CaCuO8+δ and La2-xSrxCuO4. The 2D-ACAR technique is useful in resolving the band crossings associated with the layers of the superconductors that are preferentially sampled by the positrons. Together with other Fermi surface measurements (namely angle-resolved photoemission), 2D-ACAR can resolve some of the electronic structures of high-Tc cuprate superconductors. In addition, 2D-ACAR measurements of YBa2Cu3O7-x and Bi2Sr2CaCuO8+δ also reveal an interesting temperature dependence in the fine structures, and a change in the positron lifetime in the former.

  2. Differences between the macroscopic and tracer level chemistry of rhenium and technetium: contrasting cage isomerisation behaviour of Re(I) and Tc(I) carborane complexes.

    PubMed

    Armstrong, Andrea F; Valliant, John F

    2010-09-21

    Carboranes form stable complexes with the [M(CO)(3)](+) (M = (99m)Tc, Re) core and are viable ligands for the development of targeted radiopharmaceuticals. (99m)Tc-carborane complexes were found to exhibit substantially different 1,2-->1,7 cage isomerisation behaviour than their Re counterparts, challenging the validity of the routine use of rhenium as a surrogate for the development of technetium-99m based molecular imaging agents.

  3. Measurement of methane emissions from ruminant livestock using a SF[sub 6] tracer technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, K.; Huyler, M.; Westberg, H.

    1994-02-01

    The purpose of this paper is to describe a method for determining methane emission factors for cattle. The technique involves the direct measurement of methane emissions from livestock in their natural environment. A small permeation tube containing SF[sub 6] is placed in the cow's rumen, and SF[sub 6] and CH[sub 4] concentrations are measured near the mouth and nostrils of the cow. The SF[sub 6] release provides a way to account for the dilution of gases near the animal's mouth. The CH[sub 4] emission rate can be calculated from the known SF[sub 6] emission rate and the measured SF[sub 6]more » and CH[sub 4] concentrations. The tracer method described provides an easy means for acquiring a large methane emissions data base from domestic livestock. The low cost and simplicity should make it possible to monitor a large number of animals in countries throughout the world. An expanded data base of this type helps to reduce uncertainty in the ruminant contribution to the global methane budget. 18 refs., 3 figs., 3 tabs.« less

  4. 99mTc-EDDA/HYNIC-TOC in management of patients with head and neck somatostatin receptor positive tumors.

    PubMed

    Trogrlic, Mate; Tezak, Stanko

    2016-01-01

    Aim of this study was to determine the value of technetium-99m-hydrazinonicotinyl-Tyr3-octreotide (99mTc-ED-DA/HYNIC-TOC) in patients with somatostatin receptor (SSR) positive tumors of head and neck region. A total number of 16 patients were enrolled in this study. Planar whole body (WB) and single photon emission computed tomography (SPECT) images were acquired at 2 and 4 hours after the injection of approximately 670 MBq of 99mTc-EDDA/HYNIC-TOC. Additional single photon emission computed tomography/computed tomography (SPECT/CT) images of the head and neck region were acquired at 4h post tracer injection. Clinical and imaging follow up were taken as the reference standard. There were 10 female and 6 male patients of age 57.7 ± 12.9 years (58.5; 32-78) years. 99mTc-EDDA/HYNIC-TOC somatostatin receptor scintigraphy (SRS) was TP in 13 patients, TN in two and FP in one. Follow up period for SRS was 31.1 ± 19.4 (29; 2-63) months. 99mTc-EDDA/HYNIC-TOC scintigraphy provided additional information in 50% of patients, with impact on patient management in the same percentage of patients. Distant metastases were found in nine out of 16 patients (56%). 99mTc-EDDA/HYNIC-TOC SRS had sensitivity of 100% (75.3-100%), specificity of 66.7% (9.4-99.2%), accuracy of 93.7%, positive predictive value of 92.9% (66.1-99.8%), and negative predictive value of 100% (15.8-100%). Somatostatin receptor scintigraphy using 99mTc-EDDA/HYNIC-TOC is very useful imaging method in the evalu-ation of patients with SSR positive tumors of head and neck region.

  5. Flow optimization study of a batch microfluidics PET tracer synthesizing device

    PubMed Central

    Elizarov, Arkadij M.; Meinhart, Carl; van Dam, R. Michael; Huang, Jiang; Daridon, Antoine; Heath, James R.; Kolb, Hartmuth C.

    2010-01-01

    We present numerical modeling and experimental studies of flow optimization inside a batch microfluidic micro-reactor used for synthesis of human-scale doses of Positron Emission Tomography (PET) tracers. Novel techniques are used for mixing within, and eluting liquid out of, the coin-shaped reaction chamber. Numerical solutions of the general incompressible Navier Stokes equations along with time-dependent elution scalar field equation for the three dimensional coin-shaped geometry were obtained and validated using fluorescence imaging analysis techniques. Utilizing the approach presented in this work, we were able to identify optimized geometrical and operational conditions for the micro-reactor in the absence of radioactive material commonly used in PET related tracer production platforms as well as evaluate the designed and fabricated micro-reactor using numerical and experimental validations. PMID:21072595

  6. SpecTracer: A Python-Based Interactive Solution for Echelle Spectra Reduction

    NASA Astrophysics Data System (ADS)

    Romero Matamala, Oscar Fernando; Petit, Véronique; Caballero-Nieves, Saida Maria

    2018-01-01

    SpecTracer is a newly developed interactive solution to reduce cross dispersed echelle spectra. The use of widgets saves the user the steep learning curves of currently available reduction software. SpecTracer uses well established image processing techniques based on IRAF to succesfully extract the stellar spectra. Comparisons with other reduction software, like IRAF, show comparable results, with the added advantages of ease of use, platform independence and portability. This tool can obtain meaningful scientific data and serve also as a training tool, especially for undergraduates doing research, in the procedure for spectroscopic analysis.

  7. Three-dimensional accuracy of different impression techniques for dental implants

    PubMed Central

    Nakhaei, Mohammadreza; Madani, Azam S; Moraditalab, Azizollah; Haghi, Hamidreza Rajati

    2015-01-01

    Background: Accurate impression making is an essential prerequisite for achieving a passive fit between the implant and the superstructure. The aim of this in vitro study was to compare the three-dimensional accuracy of open-tray and three closed-tray impression techniques. Materials and Methods: Three acrylic resin mandibular master models with four parallel implants were used: Biohorizons (BIO), Straumann tissue-level (STL), and Straumann bone-level (SBL). Forty-two putty/wash polyvinyl siloxane impressions of the models were made using open-tray and closed-tray techniques. Closed-tray impressions were made using snap-on (STL model), transfer coping (TC) (BIO model) and TC plus plastic cap (TC-Cap) (SBL model). The impressions were poured with type IV stone, and the positional accuracy of the implant analog heads in each dimension (x, y and z axes), and the linear displacement (ΔR) were evaluated using a coordinate measuring machine. Data were analyzed using ANOVA and post-hoc Tukey tests (α = 0.05). Results: The ΔR values of the snap-on technique were significantly lower than those of TC and TC-Cap techniques (P < 0.001). No significant differences were found between closed and open impression techniques for STL in Δx, Δy, Δz and ΔR values (P = 0.444, P = 0.181, P = 0.835 and P = 0.911, respectively). Conclusion: Considering the limitations of this study, the snap-on implant-level impression technique resulted in more three-dimensional accuracy than TC and TC-Cap, but it was similar to the open-tray technique. PMID:26604956

  8. Wear Measurement of Highly Cross-Linked UHMWPE Using a 7Be Tracer Implantation Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wimmer, Markus; Laurent, Michael P.; Dwivedi, Yash

    2013-01-29

    The very low wear rates achieved with the current highly cross-linked ultra-high molecular weight polyethylenes (UHMWPE) used in joint prostheses have proven to be difficult to measure accurately by gravimetry. Tracer methods are therefore being explored. The purpose of this study was to effect a proof-of-concept on the use of the radioactive tracer beryllium-7 (7Be) for the determination of wear in a highly cross-linked orthopedic UHMWPE. Three crosslinked and four conventional UHMWPE pins made from compression-molded GUR 1050, were activated with 109 to 1010 7Be nuclei using a new implantation setup that produced a homogenous distribution of implanted nuclei upmore » to 8.5 μm below the surface. The pins were tested for wear in a six-station pin-on-flat apparatus for up to 7.1 million cycles (178 km). A Germanium gamma detector was employed to determine activity loss of the UHMWPE pins at preset intervals during the wear test. The wear of the cross-linked UHMWPE pins was readily detected and estimated to be 17 ± 3 μg/Mc. The conventional-to-cross-linked ratio of the wear rates was 13.1 ± 0.8, in the expected range for these materials. It was estimated that implantation reduced the average wear rate by approximately 20%, and the oxidative degradation damage from implantation was negligible. Future applications of this tracer technology may include the analysis of location-specific wear, such as loss of material in the post or backside of a tibial insert.« less

  9. Hydrological tracers using nanobiotechnology: proof of concept.

    PubMed

    Sharma, Asha N; Luo, Dan; Walter, M Todd

    2012-08-21

    In order to answer questions that involve differentiating among multiple and potentially interacting hydrological flowpaths, it would be ideal to use multiple tracers with identical transport properties that can nonetheless be distinguished from each other. This paper describes the development and proof of concept of a new kind of engineered tracer system that allows a large number of individual tracers to be simultaneously distinguished from one another. This new tracer is composed of polylactic acid (PLA) microspheres into which short strands of synthetic DNA and paramagnetic iron oxide nanoparticles are incorporated. The synthetic DNA serves as the "label" or "tag" in our tracers that allow us to distinguish one tracer from another, and paramagnetic iron oxide nanoparticles are included in the tracer to facilitate magnetic concentration of the tracers in potentially dilute water samples. Some potential advantages of this tracer concept include: virtually limitless uniquely labeled tracers, highly sensitive detection, and relatively moderate expense. Three proof-of-concept experiments at scales ranging from orders of 10 cm to 100 m demonstrated the use of the tracer system.

  10. Impact of meteorological inflow uncertainty on tracer transport and source estimation in urban atmospheres

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lucas, Donald D.; Gowardhan, Akshay; Cameron-Smith, Philip

    2015-08-08

    Here, a computational Bayesian inverse technique is used to quantify the effects of meteorological inflow uncertainty on tracer transport and source estimation in a complex urban environment. We estimate a probability distribution of meteorological inflow by comparing wind observations to Monte Carlo simulations from the Aeolus model. Aeolus is a computational fluid dynamics model that simulates atmospheric and tracer flow around buildings and structures at meter-scale resolution. Uncertainty in the inflow is propagated through forward and backward Lagrangian dispersion calculations to determine the impact on tracer transport and the ability to estimate the release location of an unknown source. Ourmore » uncertainty methods are compared against measurements from an intensive observation period during the Joint Urban 2003 tracer release experiment conducted in Oklahoma City.« less

  11. Structure and Properties of fac-[Re(I)(CO)3(NTA)](2-) (NTA(3-) = Trianion of Nitrilotriacetic Acid) and fac-[Re(I)(CO)3(L)](n-) Analogues Useful for Assessing the Excellent Renal Clearance of the fac-[(99m)Tc(I)(CO)3(NTA)](2-) Diagnostic Renal Agent.

    PubMed

    Klenc, Jeffrey; Lipowska, Malgorzata; Abhayawardhana, Pramuditha L; Taylor, Andrew T; Marzilli, Luigi G

    2015-07-06

    We previously identified two new agents based on the [(99m)Tc(V)O](3+) core with renal clearances in human volunteers 30% higher than that of the widely used clinical tracer (99m)Tc-MAG3 (MAG3(5-) = penta-anion of mercaptoacetyltriglycine). However, renal agents with even higher clearances are needed. More recently, we changed our focus from the [(99m)Tc(V)O](3+) core to the discovery of superior tracers based on the fac-[(99m)Tc(I)(CO)3](+) core. Compared to (99m)Tc-MAG3, fac-[(99m)Tc(I)(CO)3(NTA)](2-) (NTA(3-) = trianion of nitrilotriacetic acid) holds great promise by virtue of its efficient renal clearance via tubular secretion and the absence of hepatobiliary elimination, even in patients with severely reduced renal function. We report here NMR, molecular (X-ray) structure, and solution data on fac-[Re(I)(CO)3(NTA)](2-) with a -CH2CO2(-) dangling monoanionic chain and on two fac-[Re(I)(CO)3(L)](-) analogues with either a -CH2CONH2 or a -CH2CH2OH dangling neutral chain. In these three fac-[Re(I)(CO)3(L)](n-) complexes, the fac-[Re(I)(CO)3(N(CH2CO2)2)](-) moiety is structurally similar and has similar electronic properties (as assessed by NMR data). In reported and ongoing studies, the two fac-[(99m)Tc(I)(CO)3(L)](-) analogues with these neutral dangling chains were found to have pharmacokinetic properties very similar to those of fac-[(99m)Tc(I)(CO)3(NTA)](2-). Therefore, we reach the unexpected conclusion that in fac-[(99m)Tc(I)(CO)3(L)](n-) agents, renal clearance is affected much more than anticipated by features of the core plus the chelate rings (the [(99m)Tc(I)(CO)3(N(CH2CO2)2)](-) moiety) than by the presence of a negatively charged dangling carboxylate chain.

  12. PREFACE: 2014 Joint IMEKO TC1-TC7-TC13 Symposium: Measurement Science Behind Safety and Security

    NASA Astrophysics Data System (ADS)

    Sousa, João A.; Ribeiro, Álvaro S.; Filipe, Eduarda

    2015-02-01

    The 2014 Joint IMEKO (International Measurement Confederation) TC1-TC7-TC13 Symposium was organized by RELACRE - Portuguese Association of Accredited Laboratories and the Portuguese Society for Metrology, on 3-5 September 2014. The work of this symposium is reported in this volume. The scope of the symposium includes the main topics covered by the above Technical Committees: - TC1 Education and Training in measurement and Instrumentation - TC7 Measurement Science - TC13 Measurements in Biology and Medicine The effort towards excellence of previous events, in this well established series, is maintained. There has been a special focus on measurement science behind safety and security, with the aim of highlighting the interdisciplinary character of measurement science and the importance of metrology in our daily lives. The discussion was introduced by keynote lectures on measurement challenges in biometrics, health monitoring and social sciences, to promote useful interactions with scientists from different disciplines. The Symposium was attended by experts working in these areas from 18 countries, including USA, Japan and China, and provided a useful forum for them to share and exchange their work and ideas. In total over fifty papers are included in the volume, organized according to the presentation sessions. Each paper was independently peer-reviewed by two reviewers from a distinguished international panel. The Symposium was held in Funchal, capital of Madeira Islands, known as the Atlantic Pearl. This wonderful Atlantic archipelago, formed by Madeira and Porto Santo islands, discovered in the 14th century, was chosen to host the 2014 IMEKO TC1-TC7-TC13 Joint Symposium ''Measurement Science behind Safety and Security''. It was the first territory discovered by the Portuguese sailors, when set out to discover a new world, in an epic journey where instrumentation and quality of measurement played a central role in the success of the enterprise, and gave an

  13. Spectroscopic Characterization of Aqua [ fac-Tc(CO)3]+ Complexes at High Ionic Strength.

    PubMed

    Chatterjee, Sayandev; Hall, Gabriel B; Engelhard, Mark H; Du, Yingge; Washton, Nancy M; Lukens, Wayne W; Lee, Sungsik; Pearce, Carolyn I; Levitskaia, Tatiana G

    2018-06-18

    Understanding fundamental Tc chemistry is important to both the remediation of nuclear waste and the reprocessing of nuclear fuel; however, current knowledge of the electronic structure and spectral signatures of low-valent Tc compounds significantly lags behind the remainder of the d-block elements. In particular, identification and treatment of Tc speciation in legacy nuclear waste is challenging due to the lack of reference data especially for Tc compounds in the less common oxidation states (I-VI). In an effort to establish a spectroscopic library corresponding to the relevant conditions of extremely high ionic strength typical for the legacy nuclear waste, compounds with the general formula of [ fac-Tc(CO) 3 (OH 2 ) 3- n (OH) n ] 1- n (where n = 0-3) were examined by a range of spectroscopic techniques including 99 Tc/ 13 C NMR, IR, XPS, and XAS. In the series of monomeric aqua species, stepwise hydrolysis results in the increase of the Tc metal center electron density and corresponding progressive decrease of the Tc-C bond distances, Tc electron binding energies, and carbonyl stretching frequencies in the order [ fac-Tc(CO) 3 (OH 2 ) 3 ] + > [ fac-Tc(CO) 3 (OH 2 ) 2 (OH)] > [ fac-Tc(CO) 3 (OH 2 )(OH) 2 ] - . These results correlate with established trends of the 99 Tc upfield chemical shift and carbonyl 13 C downfield chemical shift. The lone exception is [ fac-Tc(CO) 3 (OH)] 4 which exhibits a comparatively low electron density at the metal center attributed to the μ 3 -bridging nature of the - OH ligands causing less σ-donation and no π-donation. This work also reports the first observations of these compounds by XPS and [ fac-Tc(CO) 3 Cl 3 ] 2- by XAS. The unique and distinguishable spectral features of the aqua [ fac-Tc(CO) 3 ] + complexes lay the foundation for their identification in the complex aqueous matrixes.

  14. Comparison of denitrification activity measurements in groundwater using cores and natural-gradient tracer tests

    USGS Publications Warehouse

    Smith, R.L.; Garabedian, S.P.; Brooks, M.H.

    1996-01-01

    The transport of many solutes in groundwater is dependent upon the relative rates of physical flow and microbial metabolism. Quantifying rates of microbial processes under subsurface conditions is difficult and is most commonly approximated using laboratory studies with aquifer materials. In this study, we measured in situ rates of denitrification in a nitrate- contaminated aquifer using small-scale, natural-gradient tracer tests and compared the results with rates obtained from laboratory incubations with aquifer core material. Activity was measured using the acetylene block technique. For the tracer tests, co-injection of acetylene and bromide into the aquifer produced a 30 ??M increase in nitrous oxide after 10 m of transport (23-30 days). An advection-dispersion transport model was modified to include an acetylene-dependent nitrous oxide production term and used to simulate the tracer breakthrough curves. The model required a 4-day lag period and a relatively low sensitivity to acetylene to match the narrow nitrous oxide breakthrough curves. Estimates of in situ denitrification rates were 0.60 and 1.51 nmol of N2O produced cm-3 aquifer day-1 for two successive tests. Aquifer core material collected from the tracer test site and incubated as mixed slurries in flasks and as intact cores yielded rates that were 1.2-26 times higher than the tracer test rate estimates. Results with the coring-dependent techniques were variable and subject to the small- scale heterogeneity within the aquifer, while the tracer tests integrated the heterogeneity along a flow path, giving a rate estimate that is more applicable to transport at the scale of the aquifer.

  15. A Review of Multidimensional, Multifluid Intermediate-scale Experiments: Flow Behavior, Saturation Imaging, and Tracer Detection and Quantification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oostrom, Mart; Dane, J. H.; Wietsma, Thomas W.

    2007-08-01

    A review is presented of original multidimensional, intermediate-scale experiments involving non-aqueous phase liquid (NAPL) flow behavior, imaging, and detection/quantification with solute tracers. In a companion paper (Oostrom, M., J.H. Dane, and T.W. Wietsma. 2006. A review of multidimensional, multifluid intermediate-scale experiments: Nonaqueous phase dissolution and enhanced remediation. Vadose Zone Journal 5:570-598) experiments related to aqueous dissolution and enhanced remediation were discussed. The experiments investigating flow behavior include infiltration and redistribution experiments with both light and dense NAPLs in homogeneous and heterogeneous porous medium systems. The techniques used for NAPL saturation mapping for intermediate-scale experiments include photon-attenuation methods such as gammamore » and X-ray techniques, and photographic methods such as the light reflection, light transmission, and multispectral image analysis techniques. Solute tracer methods used for detection and quantification of NAPL in the subsurface are primarily limited to variations of techniques comparing the behavior of conservative and partitioning tracers. Besides a discussion of the experimental efforts, recommendations for future research at this laboratory scale are provided.« less

  16. Recovery and Determination of Adsorbed Technetium on Savannah River Site Charcoal Stack Samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lahoda, Kristy G.; Engelmann, Mark D.; Farmer, Orville T.

    2008-03-01

    Experimental results are provided for the sample analyses for technetium (Tc) in charcoal samples placed in-line with a Savannah River Site (SRS) processing stack effluent stream as a part of an environmental surveillance program. The method for Tc removal from charcoal was based on that originally developed with high purity charcoal. Presented is the process that allowed for the quantitative analysis of 99Tc in SRS charcoal stack samples with and without 97Tc as a tracer. The results obtained with the method using the 97Tc tracer quantitatively confirm the results obtained with no tracer added. All samples contain 99Tc at themore » pg g-1 level.« less

  17. Predictive value of tracer studies for /sup 131/I treatment in hyperthyroid cats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Broome, M.R.; Turrel, J.M.; Hays, M.T.

    In 76 cats with hyperthyroidism, peak thyroidal radioiodine (/sup 131/I) uptakes and effective half-lives were determined after administration of tracer and therapeutic activities of /sup 131/I. In 6 additional hyperthyroid cats, only peak thyroidal uptakes after administration of tracer and therapeutic activities of /sup 131/I were determined. Good correlation was found between peak thyroidal uptakes of tracer and therapeutic /sup 131/I; however, only fair correlation was observed between effective half-lives. In 79% of the cats, the effective half-life for therapeutic /sup 131/I was longer than that for tracer /sup 131/I. After administration of therapeutic activity of /sup 131/I, monoexponential andmore » biphasic decay curves were observed in 51 and 16 cats, respectively. Using therapeutic kinetic data, radiation doses to the thyroid gland were calculated retrospectively on the basis of 2 methods for determining the activity of /sup 131/I administered: (1) actual administration of tracer-compensated activity and (2) hypothetic administration of uniform activity (3 mCi). Because of the good predictive ability of tracer kinetic data for the therapeutic kinetic data, the tracer-compensated radiation doses came significantly (P = 0.008) closer to the therapeutic goal than did the uniform-activity doses. In addition, the use of tracer kinetic information reduced the extent of the tendency for consistently high uniform-activity doses. A manual method for acquiring tracer kinetic data was developed and was an acceptable alternative to computerized techniques. Adoption of this method gives individuals and institutions with limited finances the opportunity to characterize the iodine kinetics in cats before proceeding with administration of therapeutic activities of /sup 131/I.« less

  18. [Situation of supply and boom of PET imaging: what is the future for technetium-99m in nuclear medicine?].

    PubMed

    Maia, S; Ayachi Hatit, N; Paycha, F

    2011-05-01

    Molecular imaging has shown its interest in the diagnosis, staging and therapy monitoring of many diseases, especially in the field of cancer. This imaging modality can detect non-invasively early molecular changes specific to these diseases. Its expansion includes two aspects linked firstly with the advanced techniques of imaging modalities and secondly with the development of tracers as radio pharmaceuticals for imaging new molecular targets. Technetium-99m ((99m)Tc), because of its physical characteristics, its widespread availability and low cost, is the most used radionuclide in molecular imaging with the technique of single photon emission computed tomography (SPECT). Nevertheless, the current difficulty concerning the supply and the great interest of Positron Emission Tomography (PET), the "competitor" imaging modality-using molecules labelled with fluorine-18 ((18)F), legitimates the question about the future of (99m)Tc, its supremacy and the emergence of new tracer labelled with (99m)Tc. Focusing on the actual and future supply situation, the place of SPECT imaging in nuclear medicine, as well as the development of new molecules labelled with (99m)Tc is necessary to show that this radionuclide will remain essential for the speciality in the next years. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  19. A novel fluorescent retrograde neural tracer: cholera toxin B conjugated carbon dots

    NASA Astrophysics Data System (ADS)

    Zhou, Nan; Hao, Zeyu; Zhao, Xiaohuan; Maharjan, Suraj; Zhu, Shoujun; Song, Yubin; Yang, Bai; Lu, Laijin

    2015-09-01

    The retrograde neuroanatomical tracing method is a key technique to study the complex interconnections of the nervous system. Traditional tracers have several drawbacks, including time-consuming immunohistochemical or immunofluorescent staining procedures, rapid fluorescence quenching and low fluorescence intensity. Carbon dots (CDs) have been widely used as a fluorescent bio-probe due to their ultrasmall size, excellent optical properties, chemical stability, biocompatibility and low toxicity. Herein, we develop a novel fluorescent neural tracer: cholera toxin B-carbon dot conjugates (CTB-CDs). It can be taken up and retrogradely transported by neurons in the peripheral nervous system of rats. Our results show that CTB-CDs possess high photoluminescence intensity, good optical stability, a long shelf-life and non-toxicity. Tracing with CTB-CDs is a direct and more economical way of performing retrograde labelling experiments. Therefore, CTB-CDs are reliable fluorescent retrograde tracers.The retrograde neuroanatomical tracing method is a key technique to study the complex interconnections of the nervous system. Traditional tracers have several drawbacks, including time-consuming immunohistochemical or immunofluorescent staining procedures, rapid fluorescence quenching and low fluorescence intensity. Carbon dots (CDs) have been widely used as a fluorescent bio-probe due to their ultrasmall size, excellent optical properties, chemical stability, biocompatibility and low toxicity. Herein, we develop a novel fluorescent neural tracer: cholera toxin B-carbon dot conjugates (CTB-CDs). It can be taken up and retrogradely transported by neurons in the peripheral nervous system of rats. Our results show that CTB-CDs possess high photoluminescence intensity, good optical stability, a long shelf-life and non-toxicity. Tracing with CTB-CDs is a direct and more economical way of performing retrograde labelling experiments. Therefore, CTB-CDs are reliable fluorescent retrograde

  20. Modeling of CBM production, CO2 injection, and tracer movement at a field CO2 sequestration site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Siriwardane, Hema J.; Bowes, Benjamin D.; Bromhal, Grant S.

    2012-07-01

    Sequestration of carbon dioxide in unmineable coal seams is a potential technology mainly because of the potential for simultaneous enhanced coalbed methane production (ECBM). Several pilot tests have been performed around the globe leading to mixed results. Numerous modeling efforts have been carried out successfully to model methane production and carbon dioxide (CO{sub 2}) injection. Sensitivity analyses and history matching along with several optimization tools were used to estimate reservoir properties and to investigate reservoir performance. Geological and geophysical techniques have also been used to characterize field sequestration sites and to inspect reservoir heterogeneity. The fate and movement of injectedmore » CO{sub 2} can be determined by using several monitoring techniques. Monitoring of perfluorocarbon (PFC) tracers is one of these monitoring technologies. As a part of this monitoring technique, a small fraction of a traceable fluid is added to the injection wellhead along with the CO{sub 2} stream at different times to monitor the timing and location of the breakthrough in nearby monitoring wells or offset production wells. A reservoir modeling study was performed to simulate a pilot sequestration site located in the San Juan coal basin of northern New Mexico. Several unknown reservoir properties at the field site were estimated by modeling the coal seam as a dual porosity formation and by history matching the methane production and CO{sub 2} injection. In addition to reservoir modeling of methane production and CO{sub 2} injection, tracer injection was modeled. Tracers serve as a surrogate for determining potential leakage of CO{sub 2}. The tracer was modeled as a non-reactive gas and was injected into the reservoir as a mixture along with CO{sub 2}. Geologic and geometric details of the field site, numerical modeling details of methane production, CO{sub 2} injection, and tracer injection are presented in this paper. Moreover, the numerical

  1. EVALUATION OF LEAKAGE FROM FUME HOODS USING TRACER GAS, TRACER NANOPARTICLES AND NANOPOWDER HANDLING TEST METHODOLOGIES

    PubMed Central

    Dunn, Kevin H.; Tsai, Candace Su-Jung; Woskie, Susan R.; Bennett, James S.; Garcia, Alberto; Ellenbecker, Michael J.

    2015-01-01

    The most commonly reported control used to minimize workplace exposures to nanomaterials is the chemical fume hood. Studies have shown, however, that significant releases of nanoparticles can occur when materials are handled inside fume hoods. This study evaluated the performance of a new commercially available nano fume hood using three different test protocols. Tracer gas, tracer nanoparticle, and nanopowder handling protocols were used to evaluate the hood. A static test procedure using tracer gas (sulfur hexafluoride) and nanoparticles as well as an active test using an operator handling nanoalumina were conducted. A commercially available particle generator was used to produce sodium chloride tracer nanoparticles. Containment effectiveness was evaluated by sampling both in the breathing zone (BZ) of a mannequin and operator as well as across the hood opening. These containment tests were conducted across a range of hood face velocities (60, 80, and 100 feet/minute) and with the room ventilation system turned off and on. For the tracer gas and tracer nanoparticle tests, leakage was much more prominent on the left side of the hood (closest to the room supply air diffuser) although some leakage was noted on the right side and in the BZ sample locations. During the tracer gas and tracer nanoparticle tests, leakage was primarily noted when the room air conditioner was on for both the low and medium hood exhaust air flows. When the room air conditioner was turned off, the static tracer gas tests showed good containment across most test conditions. The tracer gas and nanoparticle test results were well correlated showing hood leakage under the same conditions and at the same sample locations. The impact of a room air conditioner was demonstrated with containment being adversely impacted during the use of room air ventilation. The tracer nanoparticle approach is a simple method requiring minimal setup and instrumentation. However, the method requires the reduction in

  2. Evaluation of leakage from fume hoods using tracer gas, tracer nanoparticles and nanopowder handling test methodologies.

    PubMed

    Dunn, Kevin H; Tsai, Candace Su-Jung; Woskie, Susan R; Bennett, James S; Garcia, Alberto; Ellenbecker, Michael J

    2014-01-01

    The most commonly reported control used to minimize workplace exposures to nanomaterials is the chemical fume hood. Studies have shown, however, that significant releases of nanoparticles can occur when materials are handled inside fume hoods. This study evaluated the performance of a new commercially available nano fume hood using three different test protocols. Tracer gas, tracer nanoparticle, and nanopowder handling protocols were used to evaluate the hood. A static test procedure using tracer gas (sulfur hexafluoride) and nanoparticles as well as an active test using an operator handling nanoalumina were conducted. A commercially available particle generator was used to produce sodium chloride tracer nanoparticles. Containment effectiveness was evaluated by sampling both in the breathing zone (BZ) of a mannequin and operator as well as across the hood opening. These containment tests were conducted across a range of hood face velocities (60, 80, and 100 ft/min) and with the room ventilation system turned off and on. For the tracer gas and tracer nanoparticle tests, leakage was much more prominent on the left side of the hood (closest to the room supply air diffuser) although some leakage was noted on the right side and in the BZ sample locations. During the tracer gas and tracer nanoparticle tests, leakage was primarily noted when the room air conditioner was on for both the low and medium hood exhaust airflows. When the room air conditioner was turned off, the static tracer gas tests showed good containment across most test conditions. The tracer gas and nanoparticle test results were well correlated showing hood leakage under the same conditions and at the same sample locations. The impact of a room air conditioner was demonstrated with containment being adversely impacted during the use of room air ventilation. The tracer nanoparticle approach is a simple method requiring minimal setup and instrumentation. However, the method requires the reduction in

  3. Technical Note: Coupling of chemical processes with the Modular Earth Submodel System (MESSy) submodel TRACER

    NASA Astrophysics Data System (ADS)

    Jöckel, P.; Kerkweg, A.; Buchholz, J.; Tost, H.; Sander, R.; Pozzer, A.

    2007-11-01

    The implementation of processes related to chemistry into Earth System Models and their coupling within such systems requires the consistent description of the chemical species involved. We provide a tool (written in Fortran95) to structure and manage information about constituents, herein after referred to as tracers, namely the Modular Earth Submodel System (MESSy) generic (i.e., infrastructure) submodel TRACER. With TRACER it is possible to define a multitude of tracer sets, depending on the spatio-temporal representation (i.e., the grid structure) of the model. The required information about a specific chemical species is split into the static meta-information about the characteristics of the species, and its (generally in time and space variable) abundance in the corresponding representation. TRACER moreover includes two submodels. One is TRACER_FAMILY, an implementation of the tracer family concept. It distinguishes between two types: type-1 families are usually applied to handle strongly related tracers (e.g., fast equilibrating species) for a specific process (e.g., advection). In contrast to this, type-2 families are applied for tagging techniques, in which specific species are artificially decomposed and associated with additional information, in order to conserve the linear relationship between the family and its members. The second submodel is TRACER_PDEF, which corrects and budgets numerical negative overshoots that arise in many process implementations due to the numerical limitations (limited precision, rounding errors). The submodel therefore guarantees the positive definiteness of the tracers and stabilises the integration scheme. As a by-product, it further provides a global tracer mass diagnostic. Last but not least, we present the submodel PTRAC for the definition of prognostic tracers via a Fortran95 namelist. TRACER with its submodels and PTRAC can readily be applied to a variety of models without further requirements. The code and a

  4. Diuretic renography in hydronephrosis: delayed tissue tracer transit accompanies both functional decline and tissue reorganization.

    PubMed

    Schlotmann, Andreas; Clorius, John H; Rohrschneider, Wiltrud K; Clorius, Sandra N; Amelung, Folker; Becker, Kristianna

    2008-07-01

    The significance of delayed tissue tracer transit (TTT) of (99m)Tc-mercaptoacetyltriglycine ((99m)Tc-MAG3) has not been systematically evaluated in hydronephrosis. We sought to demonstrate that delayed TTT accompanies both functional decline and histomorphologic restructuring. Twenty 2- to 3-mo-old piglets with surgically induced partial unilateral ureteral stenosis were examined with magnetic resonance urography (MRU) to evaluate morphology and with (99m)Tc-MAG3 diuretic renography (DR) to determine single-kidney function (SKF), evaluate the response to furosemide stimulation (RFS), and assess TTT. All animals had DR and MRU before and after surgery and a third DR after surgery. Piglets were sacrificed after the final DR for renal histology. A total histologic score (THS) was generated. Preoperative DR demonstrated nonobstructive RFS, timely TTT, and balanced SKF in all 20 kidneys. After ureteral ligature, MRU demonstrated pelvic dilatation in all piglets. The postoperative DRs revealed 12 kidneys with delayed TTT in one or both follow-ups. In these 12 kidneys, the SKF declined from 51% +/- 4% to 18% +/- 14%, and the THS was 9.0 +/- 4.0. Three kidneys always had timely TTT, balanced SKF, and a THS of 1.8 +/- 0.3. The contralateral, nonoperated kidneys had timely TTT and a THS of 1.2 +/- 0.9. Postoperative scintigrams showed that 3 of 8 kidneys (38%) with an obstructive RFS had timely TTT, which demonstrates that TTT and RFS are not equivalent. In hydronephrosis, a delayed TTT of (99m)Tc-MAG3 accompanies both functional decline and histomorphologic restructuring in obstruction. According to the literature, a delayed TTT is determined by the filtration fraction of the kidneys and appears to identify an obstruction-mediated upregulated renin-angiotensin system.

  5. Evaluation of drug effects on cerebral blood flow and glucose uptake in un-anesthetized and un-stimulated rats: application of free-moving apparatus enabling to keep rats free during PET/SPECT tracer injection and uptake.

    PubMed

    Sugita, Taku; Kondo, Yusuke; Ishino, Seigo; Mori, Ikuo; Horiguchi, Takashi; Ogawa, Mikako; Magata, Yasuhiro

    2018-05-15

    The purpose of this study is the development of novel fluorine-18-fluorodeoxyglucose (F-FDG)-PET and Tc-hexamethylpropylene amine oxime (HMPAO) SPECT methods with free-moving apparatus on conscious rats to investigate brain activity without the effects of anesthesia and tactual stimulation. We also assessed the sensitivity of the experimental system by an intervention study using fluoxetine as a reference drug. A catheter was inserted into the femoral vein and connected to a free-moving cannula system. After fluoxetine administration, the rats were given an injection of F-FDG or Tc-HMPAO via the intravenous cannula and released into a free-moving cage. After the tracer was trapped in the brain, the rats were anesthetized and scanned with PET or SPECT scanners. Then a volume of interest analysis and statistical parametric mapping were performed. We could inject the tracer without touching the rats, while keeping them conscious until the tracers were distributed and trapped in the brain using the developed system. The effects of fluoxetine on glucose uptake and cerebral blood flow were perceptively detected by volume of interest and statistical parametric mapping analysis. We successfully developed free-moving F-FDG-PET and Tc-HMPAO-SPECT imaging systems and detected detailed glucose uptake and cerebral blood flow changes in the conscious rat brain with fluoxetine administration. This system is expected to be useful to assess brain activity without the effects of anesthesia and tactual stimulation to evaluate drug effect or animal brain function.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0/.

  6. Use of hydrochemistry as a standalone and complementary groundwater age tracer

    NASA Astrophysics Data System (ADS)

    Beyer, Monique; Jackson, Bethanna; Daughney, Chris; Morgenstern, Uwe; Norton, Kevin

    2016-12-01

    Groundwater age or residence time is the time water has resided in the subsurface since recharge. This can provide information on groundwater mixing and flow, and volumes of groundwater and recharge, etc. Groundwater age can be inferred from environmental tracers, such as SF6 and tritium that have a known input to groundwater and/or undergo known alteration processes in groundwater. Multiple tracers are often applied complementarily in order to increase the robustness of age interpretations. To this end, it is desirable to develop cost-effective and easily applicable age tracers/techniques to supplement the existing ones. A number of hydrochemical parameters are spatially and temporally widely available due to national and regional groundwater monitoring programmes. Their determination is cost-effective and relatively simple compared to existing age tracers. Hydrochemistry has been used as an age proxy but its use as an independent age tracer has only been demonstrated for water recharged weeks to months ago (relying on seasonal changes). This study focuses on the Lower Hutt Groundwater Zone, New Zealand, and assesses whether hydrochemistry can be used as an independent indicator of groundwater age, or if not, whether hydrochemistry can be used to complement groundwater age measurements based on other tracers. This study also examines the use of hydrochemistry as an indicator for recharge sources and weathering processes. This study shows that, when used independently, hydrochemistry could only be used as an age proxy, but in combination with tritium measurements, hydrochemistry provided useful additional constraint on age of groundwater recharged days to ∼100 years ago.

  7. Ibuprofen induces reduction of the proliferation-seeking radiotracer 99mTc-(V)DMSA uptake in severe epithelial breast hyperplasia without atypia.

    PubMed

    Papantoniou, Vassilios; Tsaroucha, Angeliki; Valsamaki, Pipitsa; Tsiouris, Spyridon; Sotiropoulou, Evangelia; Karianos, Theodore; Marinopoulos, Spyridon; Fothiadaki, Athina; Sotiropoulou, Maria; Archontaki, Aikaterini; Syrgiannis, Konstantinos; Dimitrakakis, Konstantinos; Antsaklis, Aris

    2010-10-01

    The purpose of this study was to investigate if ibuprofen intake can influence mammary uptake of the proliferation-seeking radiotracer technetium 99m-pentavalent dimercaptosuccinic acid (99mTc-(V)DMSA) in women with severe epithelial and atypical epithelial breast hyperplasia. Eight patients with histologically confirmed severe epithelial breast hyperplasia with (n  =  4) and without atypia (n  =  4) were submitted prospectively to 99mTc-(V)DMSA scintimammography before and after a 4-week course of 400 mg ibuprofen daily oral intake. Lesion to background ratios 60 minutes postinjection were calculated and compared (t-test) before and after ibuprofen administration. Prior to ibuprofen, the patients with severe epithelial hyperplasia displayed a significantly higher 99mTc-(V)DMSA uptake ratio compared to those with atypical epithelial hyperplasia (2.40 ± 0.32 vs 1.67 ± 0.09, respectively; p  =  .003). They also exhibited a more substantial percent decline in tracer uptake postibuprofen compared to women with atypical epithelial hyperplasia (62.0 ± 7.1 vs 15.0 ± 0.2, respectively; p  =  .001). Ibuprofen induces significant uptake reduction of the proliferation-seeking radiotracer 99mTc-(V)DMSA in severe epithelial breast hyperplasia without atypia. This agent could therefore constitute a potential imaging tool for monitoring chemoprophylaxis effectiveness in women at the early stages of malignant transformation.

  8. Emission quantification using the tracer gas dispersion method: The influence of instrument, tracer gas species and source simulation.

    PubMed

    Delre, Antonio; Mønster, Jacob; Samuelsson, Jerker; Fredenslund, Anders M; Scheutz, Charlotte

    2018-09-01

    The tracer gas dispersion method (TDM) is a remote sensing method used for quantifying fugitive emissions by relying on the controlled release of a tracer gas at the source, combined with concentration measurements of the tracer and target gas plumes. The TDM was tested at a wastewater treatment plant for plant-integrated methane emission quantification, using four analytical instruments simultaneously and four different tracer gases. Measurements performed using a combination of an analytical instrument and a tracer gas, with a high ratio between the tracer gas release rate and instrument precision (a high release-precision ratio), resulted in well-defined plumes with a high signal-to-noise ratio and a high methane-to-tracer gas correlation factor. Measured methane emission rates differed by up to 18% from the mean value when measurements were performed using seven different instrument and tracer gas combinations. Analytical instruments with a high detection frequency and good precision were established as the most suitable for successful TDM application. The application of an instrument with a poor precision could only to some extent be overcome by applying a higher tracer gas release rate. A sideward misplacement of the tracer gas release point of about 250m resulted in an emission rate comparable to those obtained using a tracer gas correctly simulating the methane emission. Conversely, an upwind misplacement of about 150m resulted in an emission rate overestimation of almost 50%, showing the importance of proper emission source simulation when applying the TDM. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Identification of novel mammalian hosts and Brazilian biome geographic distribution of Trypanosoma cruzi TcIII and TcIV.

    PubMed

    Barros, Juliana Helena S; Xavier, Samanta Cristina C; Bilac, Daniele; Lima, Valdirene Santos; Dario, Maria Augusta; Jansen, Ana Maria

    2017-08-01

    Trypanosoma cruzi is a parasitic protozoan responsible for Chagas disease. Seven different Discrete Typing Units (DTUs) of T. cruzi are currently identified in nature: TcI-TcVI, and TcBat whose distribution patterns in nature, hosts/reservoirs and eco-epidemiological importance are still little known. Here, we present novel data on the geographic distribution and diversity of mammalian hosts and vectors of T. cruzi DTUs TcIII and TcIV. In this study, we analyzed 61 T. cruzi isolates obtained from 18 species of mammals (five orders) and two Hemiptera genera. Samples were collected from five Brazilian biomes (Pantanal, Caatinga, Cerrado, Atlantic Rainforest, and Amazon) previously characterized as Z3 or mixed infection (TcI-Z3) by mini-exon gene PCR. To identify TcIII and TcIV genotypes, we applied restriction fragment length polymorphism analysis to the PCR-amplified histone 3 gene. DTUs TcIII and TcIV were identified in single and mixed infections from wide dispersion throughout five Brazilian biomes studied, with TcIV being the most common. Pantanal was the biome that displayed the largest number of samples characterized as TcIII and TcIV in single and mixed infections, followed by Atlantic Rainforest and Amazon. Species from the Didelphimorphia order displayed the highest frequency of infection and were found in all five biomes. We report, for the first time, the infection of a species of the Artiodactyla order by DTU TcIII. In addition, we describe new host species: five mammals (marsupials and rodents) and two genera of Hemiptera. Our data indicate that DTUs TcIII and TcIV are more widespread and infect a larger number of mammalian species than previously thought. In addition, they are transmitted in restricted foci and cycles, but in different microhabitats and areas with distinct ecological profiles. Finally, we show that DTUs TcIII and TcIV do not present any specific association with biomes or host species. Copyright © 2017. Published by Elsevier B.V.

  10. Combined use of fluorescence with a magnetic tracer and dilution effect upon sentinel node localization in a murine model.

    PubMed

    Kuwahata, Akihiro; Ahmed, Muneer; Saeki, Kohei; Chikaki, Shinichi; Kaneko, Miki; Qiu, Wenqi; Xin, Zonghao; Yamaguchi, Shinji; Kaneko, Akiko; Douek, Michael; Kusakabe, Moriaki; Sekino, Masaki

    2018-01-01

    Sentinel node biopsy using radioisotope and blue dye remains a gold standard for axillary staging in breast cancer patients with low axillary burden. However, limitations in the use of radioisotopes have resulted in emergence of novel techniques. This is the first in vivo study to assess the feasibility of combining the two most common novel techniques of using a magnetic tracer and indocyanine green (ICG) fluorescence. A total of 48 mice were divided into eight groups. Groups 1 and 2, the co-localization groups, received an injection of magnetic tracers (Resovist ® and Sienna+ ® , respectively) and ICG fluorescence; distilled water was used as the solvent of ICG. Groups 3 and 4, the diluted injection groups, received an injection of magnetic tracers (Resovist and Sienna+, respectively) and saline for dilution. Groups 5, 6, and 7, the control groups, received magnetic tracer (Resovist, Sienna+) and ICG alone, respectively. Fluorescent intensity assessment and iron quantification of excised popliteal lymph nodes were performed. Group 1', a co-localization group, received an injection of magnetic tracers (Resovist) and ICG' fluorescence: saline was used as the solvent for ICG. Lymphatic uptake of all tracers was confined to the popliteal nodes only, with co-localization confirmed in all cases and no significant difference in fluorescent intensity or iron content of ex vivo nodes between the groups (except for Group 1'). There was no impact of dilution on the iron content in the diluted Sienna+ group, but it significantly enhanced Resovist uptake ( P =0.005). In addition, there was a significant difference in iron content ( P =0.003) in Group 1'. The combination of a magnetic tracer (Resovist or Sienna+) and ICG fluorescence is feasible for sentinel node biopsy and will potentially allow for precise transcutaneous node identification, in addition to accurate intraoperative assessment. This radioisotope-free "combined technique" warrants further assessment within a

  11. Measurement of absolute myocardial blood flow in humans using dynamic cardiac SPECT and 99mTc-tetrofosmin: Method and validation

    DOE PAGES

    Shrestha, Uttam; Sciammarella, Maria; Alhassen, Fares; ...

    2015-12-29

    The objective of this study was to measure myocardial blood flow (MBF) in humans using 99mTc-tetrofosmin and dynamic single-photon emission computed tomography (SPECT). Dynamic SPECT using 99mTc-tetrofosmin and dynamic positron emission tomography (PET) was performed on a group of 16 patients. The SPECT data were reconstructed using a 4D-spatiotemporal iterative reconstruction method. The data corresponding to 9 patients were used to determine the flow-extraction curve for 99mTc-tefrofosmin while data from the remaining 7 patients were used for method validation. The nonlinear tracer correction parameters A and B for 99mTc-tefrofosmin were estimated for the 9 patients by fitting the flow-extraction curvemore » K 1 = F(1–Aexp(–B/F)) for K 1 values estimated with 99mTc-tefrofosmin using SPECT and MBF values estimated with 13N-NH 3 using PET. These parameters were then used to calculate MBF and coronary flow reserve (CFR) in three coronary territories (LAD, RCA, and LCX) using SPECT for an independent cohort of 7 patients. The results were then compared with that estimated with 13N-NH 3 PET. The flow-dependent permeability surface-area product (PS) for 99mTc-tefrofosmin was also estimated. The estimated flow-extraction parameters for 99mTc-tefrofosmin were found to be A = 0.91 ± 0.11, B = 0.34 ± 0.20 (R 2 = 0.49). The range of MBF in LAD, RCA, and LCX was 0.44-3.81 mL/min/g. The MBF between PET and SPECT in the group of independent cohort of 7 patients showed statistically significant correlation, r = 0.71 (P < .001). However, the corresponding CFR correlation was moderate r = 0.39 yet statistically significant (P = .037). The PS for 99mTc-tefrofosmin was (0.019 ± 0.10)*MBF + (0.32 ± 0.16). Dynamic cardiac SPECT using 99mTc-tetrofosmin and a clinical two-headed SPECT/CT scanner can be a useful tool for estimation of MBF.« less

  12. Measurement of absolute myocardial blood flow in humans using dynamic cardiac SPECT and 99mTc-tetrofosmin: Method and validation.

    PubMed

    Shrestha, Uttam; Sciammarella, Maria; Alhassen, Fares; Yeghiazarians, Yerem; Ellin, Justin; Verdin, Emily; Boyle, Andrew; Seo, Youngho; Botvinick, Elias H; Gullberg, Grant T

    2017-02-01

    The objective of this study was to measure myocardial blood flow (MBF) in humans using 99m Tc-tetrofosmin and dynamic single-photon emission computed tomography (SPECT). Dynamic SPECT using 99m Tc-tetrofosmin and dynamic positron emission tomography (PET) was performed on a group of 16 patients. The SPECT data were reconstructed using a 4D-spatiotemporal iterative reconstruction method. The data corresponding to 9 patients were used to determine the flow-extraction curve for 99m Tc-tefrofosmin while data from the remaining 7 patients were used for method validation. The nonlinear tracer correction parameters A and B for 99m Tc-tefrofosmin were estimated for the 9 patients by fitting the flow-extraction curve [Formula: see text] for K 1 values estimated with 99m Tc-tefrofosmin using SPECT and MBF values estimated with 13 N-NH 3 using PET. These parameters were then used to calculate MBF and coronary flow reserve (CFR) in three coronary territories (LAD, RCA, and LCX) using SPECT for an independent cohort of 7 patients. The results were then compared with that estimated with 13 N-NH 3 PET. The flow-dependent permeability surface-area product (PS) for 99m Tc-tefrofosmin was also estimated. The estimated flow-extraction parameters for 99m Tc-tefrofosmin were found to be A = 0.91 ± 0.11, B = 0.34 ± 0.20 (R 2  = 0.49). The range of MBF in LAD, RCA, and LCX was 0.44-3.81 mL/min/g. The MBF between PET and SPECT in the group of independent cohort of 7 patients showed statistically significant correlation, r = 0.71 (P < .001). However, the corresponding CFR correlation was moderate r = 0.39 yet statistically significant (P = .037). The PS for 99m Tc-tefrofosmin was (0.019 ± 0.10)*MBF + (0.32 ± 0.16). Dynamic cardiac SPECT using 99m Tc-tetrofosmin and a clinical two-headed SPECT/CT scanner can be a useful tool for estimation of MBF.

  13. Measurement of Absolute Myocardial Blood Flow in Humans Using Dynamic Cardiac SPECT and 99mTc-tetrofosmin: Method and Validation

    PubMed Central

    Shrestha, Uttam; Sciammarella, Maria; Alhassen, Fares; Yeghiazarians, Yerem; Ellin, Justin; Verdin, Emily; Boyle, Andrew; Seo, Youngho; Botvinick, Elias H.; Gullberg, Grant T.

    2015-01-01

    Background The objective of this study was to measure myocardial blood flow (MBF) in humans using 99mTc-tetrofosmin and dynamic single photon emission computed tomography (SPECT). Methods Dynamic SPECT using 99mTc-tetrofosmin and dynamic positron emission tomography (PET) was performed on a group of 16 patients. The SPECT data were reconstructed using a 4D-spatiotemporal iterative reconstruction method. The data corresponding to 9 patients were used to determine the flow-extraction curve for 99mTc-tefrofosmin while data from the remaining 7 patients were used for method validation. The nonlinear tracer correction parameters A and B for 99mTc-tefrofosmin were estimated for the 9 patients by fitting the flow-extraction curve K1=F(1−Aexp(−BF)) for K1 values estimated with 99mTc-tefrofosmin using SPECT and MBF values estimated with 13N-NH3 using PET. These parameters were then used to calculate MBF and coronary flow reserve (CFR) in three coronary territories (LAD, RCA, and LCX) using SPECT for an independent cohort of 7 patients. The results were then compared with that estimated with 13N-NH3 PET. The flow dependent permeability surface-area product (PS) for 99mTc-tefrofosmin was also estimated. Results The estimated flow extraction parameters for 99mTc-tefrofosmin was found to be A=0.91±0.11, B=0.34±0.20 (R2 = 0.49). The range of MBF in LAD, RCA, and LCX was 0.44 ml/min/g to 3.81 ml/min/g. The MBF between PET and SPECT in the group of independent cohort of 7 patients showed statistically significant correlation, r = 0.71 (p < 0.001). However, the corresponding CFR correlation was moderate r = 0.39 yet statistically significant (p = 0.037). The PS for 99mTc-tefrofosmin was (0.091 ± 0.10) * MBF = (0.32 ± 0.16). Conclusions Dynamic cardiac SPECT using 99mTc-tetrofosmin and a clinical two-headed SPECT/CT scanner can be a useful tool for estimation of MBF. PMID:26715603

  14. Measurement of absolute myocardial blood flow in humans using dynamic cardiac SPECT and 99mTc-tetrofosmin: Method and validation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shrestha, Uttam; Sciammarella, Maria; Alhassen, Fares

    The objective of this study was to measure myocardial blood flow (MBF) in humans using 99mTc-tetrofosmin and dynamic single-photon emission computed tomography (SPECT). Dynamic SPECT using 99mTc-tetrofosmin and dynamic positron emission tomography (PET) was performed on a group of 16 patients. The SPECT data were reconstructed using a 4D-spatiotemporal iterative reconstruction method. The data corresponding to 9 patients were used to determine the flow-extraction curve for 99mTc-tefrofosmin while data from the remaining 7 patients were used for method validation. The nonlinear tracer correction parameters A and B for 99mTc-tefrofosmin were estimated for the 9 patients by fitting the flow-extraction curvemore » K 1 = F(1–Aexp(–B/F)) for K 1 values estimated with 99mTc-tefrofosmin using SPECT and MBF values estimated with 13N-NH 3 using PET. These parameters were then used to calculate MBF and coronary flow reserve (CFR) in three coronary territories (LAD, RCA, and LCX) using SPECT for an independent cohort of 7 patients. The results were then compared with that estimated with 13N-NH 3 PET. The flow-dependent permeability surface-area product (PS) for 99mTc-tefrofosmin was also estimated. The estimated flow-extraction parameters for 99mTc-tefrofosmin were found to be A = 0.91 ± 0.11, B = 0.34 ± 0.20 (R 2 = 0.49). The range of MBF in LAD, RCA, and LCX was 0.44-3.81 mL/min/g. The MBF between PET and SPECT in the group of independent cohort of 7 patients showed statistically significant correlation, r = 0.71 (P < .001). However, the corresponding CFR correlation was moderate r = 0.39 yet statistically significant (P = .037). The PS for 99mTc-tefrofosmin was (0.019 ± 0.10)*MBF + (0.32 ± 0.16). Dynamic cardiac SPECT using 99mTc-tetrofosmin and a clinical two-headed SPECT/CT scanner can be a useful tool for estimation of MBF.« less

  15. Diagnostic value of 99mTc-bombesin scintigraphy for differentiation of malignant from benign breast lesions.

    PubMed

    Shariati, Farzaneh; Aryana, Kamran; Fattahi, Asiehsadat; Forghani, Mohammad N; Azarian, Azita; Zakavi, Seyed R; Sadeghi, Ramin; Ayati, Narjes; Sadri, Keyvan

    2014-06-01

    In this study, we evaluated the diagnostic accuracy of (99m)Tc-bombesin scintigraphy for differentiation of benign from malignant palpable breast lesions. (99m)Tc-Bombesin is a tracer with high affinity for gastrin-releasing peptide receptor, which is overexpressed on a variety of human tumors including breast carcinoma. We examined 33 consecutive women who were referred to our center with suspicious palpable breast lesions but had no definitive diagnosis in other imaging procedures. A volume of 370-444 MBq of (99m)Tc-bombesin was injected and dynamic 1-min images were taken for 20 min immediately after injection in anterior view. Thereafter, two static images in anterior and prone-lateral views were taken for 5 min. Finally, single-photon emission computed tomography images were taken for each patient. Definitive diagnosis was based on biopsy and histopathological evaluation. The scan findings were positive in 19 patients and negative in 11 on visual assessment of the planar and single-photon emission computed tomography images. Pathologic examination confirmed breast carcinoma in 12 patients with positive scans and benign pathology for 18 patients. The overall sensitivity, specificity, negative and positive predictive values, and accuracy of this radiotracer for diagnosis of breast cancer were 100, 66.1, 100, 63, and 76%, respectively. Semiquantitative analysis improved the specificity of the visual assessment from 66 to 84%. Our study showed that (99m)Tc-bombesin scintigraphy has a high sensitivity and negative predictive value for detecting malignant breast lesions, but the specificity and positive predictive value of this radiotracer for differentiation of malignant breast abnormalities from benign ones are relatively low.

  16. [The clinical value of sentinel lymph node detection in laryngeal and hypopharyngeal carcinoma patients with clinically negative neck by methylene blue method and radiolabeled tracer method].

    PubMed

    Zhao, Xin; Xiao, Dajiang; Ni, Jianming; Zhu, Guochen; Yuan, Yuan; Xu, Ting; Zhang, Yongsheng

    2014-11-01

    To investigate the clinical value of sentinel lymph node (SLN) detection in laryngeal and hypopharyngeal carcinoma patients with clinically negative neck (cN0) by methylene blue method, radiolabeled tracer method and combination of these two methods. Thirty-three patients with cN0 laryngeal carcinoma and six patients with cN0 hypopharyngeal carcinoma underwent SLN detection using both of methylene blue and radiolabeled tracer method. All these patients were accepted received the injection of radioactive isotope 99 Tc(m)-sulfur colloid (SC) and methylene blue into the carcinoma before surgery, then all these patients underwent intraopertive lymphatic mapping with a handheld gamma-detecting probe and blue-dyed SLN. After the mapping of SLN, selected neck dissections and tumor resections were peformed. The results of SLN detection by radiolabeled tracer, dye and combination of both methods were compared. The detection rate of SLN by radiolabeled tracer, methylene blue and combined method were 89.7%, 79.5%, 92.3% respectively. The number of detected SLN was significantly different between radiolabeled tracer method and combined method, and also between methylene blue method and combined method. The detection rate of methylene blue and radiolabeled tracer method were significantly different from combined method (P < 0.05). Nine patients were found to have lymph node metastasis by final pathological examination. The accuracy and negative rate of SLN detection of the combined method were 97.2% and 11.1%. The combined method using radiolabeled tracer and methylene blue can improve the detection rate and accuracy of sentinel lymph node detection. Furthermore, sentinel lymph node detection can accurately represent the cervical lymph node status in cN0 laryngeal and hypopharyngeal carcinoma.

  17. In-house cyclotron production of high-purity Tc-99m and Tc-99m radiopharmaceuticals.

    PubMed

    Martini, Petra; Boschi, Alessandra; Cicoria, Gianfranco; Zagni, Federico; Corazza, Andrea; Uccelli, Licia; Pasquali, Micòl; Pupillo, Gaia; Marengo, Mario; Loriggiola, Massimo; Skliarova, Hanna; Mou, Liliana; Cisternino, Sara; Carturan, Sara; Melendez-Alafort, Laura; Uzunov, Nikolay M; Bello, Michele; Alvarez, Carlos Rossi; Esposito, Juan; Duatti, Adriano

    2018-05-30

    In the last years, the technology for producing the important medical radionuclide technetium-99m by cyclotrons has become sufficiently mature to justify its introduction as an alternative source of the starting precursor [ 99m Tc][TcO 4 ] - ubiquitously employed for the production of 99m Tc-radiopharmaceuticals in hospitals. These technologies make use almost exclusively of the nuclear reaction 100 Mo(p,2n) 99m Tc that allows direct production of Tc-99m. In this study, it is conjectured that this alternative production route will not replace the current supply chain based on the distribution of 99 Mo/ 99m Tc generators, but could become a convenient emergency source of Tc-99m only for in-house hospitals equipped with a conventional, low-energy, medical cyclotron. On this ground, an outline of the essential steps that should be implemented for setting up a hospital radiopharmacy aimed at the occasional production of Tc-99m by a small cyclotron is discussed. These include (1) target production, (2) irradiation conditions, (3) separation/purification procedures, (4) terminal sterilization, (5) quality control, and (6) Mo-100 recovery. To address these issues, a comprehensive technology for cyclotron-production of Tc-99m, developed at the Legnaro National Laboratories of the Italian National Institute of Nuclear Physics (LNL-INFN), will be used as a reference example. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Toward organometallic (99m)Tc imaging agents: synthesis of water-stable (99)Tc-NHC complexes.

    PubMed

    Benz, Michael; Spingler, Bernhard; Alberto, Roger; Braband, Henrik

    2013-11-20

    (99)Tc(V)O2-NHC complexes containing monodentate and bidentate N-heterocyclic carbenes (NHCs) have been prepared by the reactions of [TcO(glyc)2](-) (glyc = ethyleneglycolato) with 1,3-dimethylimidazoline-2-ylidene (L1), 1,1'-methylene-3,3'-dimethyl-4,4'-diimidazoline-2,2'-diylidene (L2), and 1,1'-methylene-3,3'-diethyl-4,4'-diimidazoline-2,2'-diylidene (L3) in THF. The resulting complexes were fully characterized and their stabilities investigated. While complexes with monodentate NHCs only are hydrolytically unstable, complexes containing bidentate NHCs are water-stable over a broad pH range. The high water stability allows interconversion of the {(99)Tc(V)O2}(+) core into {(99)Tc(V)OCl}(2+) with HCl as the H(+) and Cl(-) source. An alternative procedure to obtain (99)Tc(V)O2-NHC complexes is the in situ deprotonation of imidazolium salts, enabling the preparation of (99)Tc(V)O2-NHC compounds without free NHCs, thus increasing the scope of NHC ligands drastically. The remarkable stability and pH-controllable reactivity of the new complexes underlines the potential of NHCs as stabilizing ligands for (99)Tc complexes and paves the way for the first (99m)Tc-NHC complexes in the future.

  19. Preclinical characterization of 18F-MAA, a novel PET surrogate of 99mTc-MAA.

    PubMed

    Wu, Shih-Yen; Kuo, Jia-Wei; Chang, Tien-Kuei; Liu, Ren-Shen; Lee, Rheun-Chuan; Wang, Shyh-Jen; Lin, Wuu-Jyh; Wang, Hsin-Ell

    2012-10-01

    (99m)Tc-labeled macroaggregated albumin ((99m)Tc-MAA) scintigraphy scan is routinely performed for lung perfusion imaging and for the assessment of in vivo distribution of (90)Y-labeled SIR-Spheres prior to selective internal radiation treatment for hepatocellular carcinoma. Positron emission tomography (PET) imaging is superior to gamma scintigraphy in terms of sensitivity, spatial resolution and accuracy of quantification. This study reported that (18)F-labeled macroaggregated albumin ((18)F-MAA) is an ideal PET imaging surrogate for (99m)Tc-MAA. (18)F-MAA was prepared from the commercial MAA kit via a one-step conjugation with N-succinimidyl 4-(18)F-fluorobenzoate ((18)F-SFB). The biodistribution study and microPET/microSPECT imaging were conducted in normal SD rats after intravenous injection of (18)F-MAA/(99m)Tc-MAA. A comparison study of these two radiotracers was performed after co-injection via the intrahepatic arterial in a N1S1 hepatoma-bearing SD rat model. The optimal condition for (18)F-MAA preparation is coupling MAA (0.5mg) with (18)F-SFB at 45°C for 5 min in a phosphate buffer of pH 8.5. (18)F-MAA was prepared in 60 min with high radiochemical yield (30%-35%) and high radiochemical purity (>95%). The in vivo distribution of (18)F-MAA after intravenous injection meets the specifications of MAA depicted in European Pharmacopeia. Our study demonstrated excellent correlation between (18)F-MAA and (99m)Tc-MAA in the regional distribution of tumor, liver and lungs (R(2)=0.965, 0.886 and 0.991, respectively), and also in the tumor-to-liver and tumor-to-lungs ratio (R(2)=0.965 and 0.987, respectively) in a N1S1 hepatoma-bearing SD rat model. The organ uptakes derived from animal PET/CT and SPECT/CT imaging after administration of these two tracers were in accordance with those obtained in the distribution studies. Starting from commercial MAA kit, an efficient preparation of (18)F-MAA was successfully established. Highly correlated, almost parallel

  20. Evaluation of a 99mTc-labeled AnnexinA5 variant for non-invasive SPECT imaging of cell death in liver, spleen and prostate.

    PubMed

    Greupink, Rick; Sio, Charles F; Ederveen, Antwan; Orsel, Joke

    2009-12-01

    We investigate radio-labeling and pharmacokinetics of a new AnnexinA5 variant (HYNIC-cys-AnxA5) and then assess its utility for the non-invasive detection of cell death in liver, spleen and prostate. AnnexinA5 binds to phosphatidylserine expressed on the surface of apoptotic and necrotic cells. Contrary to other AnnexinA5 variants, the new cys-AnxA5 allows for site-specific conjugation of a hydrazinonicotinamide-maleimide moiety and subsequent radio-labeling with (99m)Tc at a position not involved in the AnxA5-phosphatidylserine interaction. Distribution of (99m)Tc-HYNIC-cys-AnxA5 was studied in rats, both invasively and via SPECT/CT. Cycloheximide was used to induce cell death in liver and spleen, whereas apoptosis in the prostate was induced by castration. HYNIC-cys-AnxA5 was efficiently and reproducibly labeled with (99m)Tc. Blood clearance of radioactivity after iv-injection was adequately described by a two-compartment model, the renal cortex representing the main site of accumulation. Cycloheximide treatment resulted in increased accumulation of intravenous-injected (99m)Tc-HYNIC-cys-AnxA5 in liver and spleen over controls, which correlated well with TUNEL staining for cell death in corresponding tissue sections. However, the increase in TUNEL-positive prostate epithelial cells observed following castration was not paralleled by greater (99m)Tc-HYNIC-cys-AnxA5 accumulation. (99m)Tc-HYNIC-cys-AnxA5 appears a suitable tracer for assessment of cell death in liver and spleen, but not prostate.

  1. Photoacoustic infrared spectroscopy for conducting gas tracer tests and measuring water saturations in landfills

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jung, Yoojin; Han, Byunghyun; Mostafid, M. Erfan

    2012-02-15

    Highlights: Black-Right-Pointing-Pointer Photoacoustic infrared spectroscopy tested for measuring tracer gas in landfills. Black-Right-Pointing-Pointer Measurement errors for tracer gases were 1-3% in landfill gas. Black-Right-Pointing-Pointer Background signals from landfill gas result in elevated limits of detection. Black-Right-Pointing-Pointer Technique is much less expensive and easier to use than GC. - Abstract: Gas tracer tests can be used to determine gas flow patterns within landfills, quantify volatile contaminant residence time, and measure water within refuse. While gas chromatography (GC) has been traditionally used to analyze gas tracers in refuse, photoacoustic spectroscopy (PAS) might allow real-time measurements with reduced personnel costs and greater mobilitymore » and ease of use. Laboratory and field experiments were conducted to evaluate the efficacy of PAS for conducting gas tracer tests in landfills. Two tracer gases, difluoromethane (DFM) and sulfur hexafluoride (SF{sub 6}), were measured with a commercial PAS instrument. Relative measurement errors were invariant with tracer concentration but influenced by background gas: errors were 1-3% in landfill gas but 4-5% in air. Two partitioning gas tracer tests were conducted in an aerobic landfill, and limits of detection (LODs) were 3-4 times larger for DFM with PAS versus GC due to temporal changes in background signals. While higher LODs can be compensated by injecting larger tracer mass, changes in background signals increased the uncertainty in measured water saturations by up to 25% over comparable GC methods. PAS has distinct advantages over GC with respect to personnel costs and ease of use, although for field applications GC analyses of select samples are recommended to quantify instrument interferences.« less

  2. Extending the Collection Duration of Breath Samples for Enteric Methane Emission Estimation Using the SF6 Tracer Technique

    PubMed Central

    Pinares-Patiño, César; Gere, José; Williams, Karen; Gratton, Roberto; Juliarena, Paula; Molano, German; MacLean, Sarah; Sandoval, Edgar; Taylor, Grant; Koolaard, John

    2012-01-01

    Simple Summary Extended sample collection for the SF6 tracer technique is desirable for extensive grazing systems. Breath samples from eight cows were collected while lucerne silage was fed to achieve fixed intakes among the cows. Samples were collected over a 10-day period, using either apparatuses used in New Zealand (NZL) or Argentina (ARG), and either daily, over two consecutive 5-day periods or over a 10-day period (in duplicate). The NZL system had a greater sampling success and more consistent CH4 emission estimates than the ARG system, with no differences in mean emissions among sample collection periods. This study showed that extended sample collection is feasible, but definitive evaluation under grazing situation is required before a decision on recommendation can be made. Abstract The daily sample collection protocol of the sulphur hexafluoride (SF6) tracer technique for the estimation of methane (CH4) emissions from ruminants may not be practical under extensive grazing systems. Here, under controlled conditions, we evaluated extended periods of sampling as an alternative to daily sample collections. Eight rumen-fistulated cows were housed and fed lucerne silage to achieve common daily feed intakes of 6.4 kg dry matter per cow. Following SF6 permeation tube dosing, eight sampling lines were fitted to the breath collection harness, so that a common gas mix was available to each line. Half of the lines collected samples into PVC yokes using a modified capillary system as commonly used in New Zealand (NZL), and half collected samples into stainless steel cylinders using a ball-bearing flow restrictor as used in Argentina (ARG), all within a 10-day time frame, either daily, across two consecutive 5-day periods or across one 10-day period (in duplicate). The NZL system had greater sampling success (97.3 vs. 79.5%) and yielded more consistent CH4 emission estimates than the ARG system. Emission estimates from NZL daily, NZL 5-day and NZL 10-day samplings

  3. Tc-99m-galactosyl-neoglycoalbumin (Tc-NGA) liver imaging: Potential application in liver transplantation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woodle, E.S.; Vera, D.R.; Ward, R.E.

    1984-01-01

    Tc-NGA is a hepatocyte receptor-specific imaging agent whose uptake by the liver has been shown to be dependent upon blood flow and receptor concentration. The combination of anatomic and physiologic information obtained with Tc-NGA may provide a new tool for studying hepatic function in liver transplant recipients. To evaluate the potential role of Tc-NGA in liver transplant recipients, studies were performed in four groups of pigs: controls (n=18); common bile duct (CBD) ligation (n=8); orthotopic liver transplant (n=9); and acute hepatic artery ligation (n=1). Serial studies performed in two animals with CBD ligation demonstrated normal imaging anatomy with minor changesmore » in the hepatic time-activity curves when compared to control studies. Studies in liver-transplanted animals showed significant changes in the hepatic time-activity curves during acute rejection and in preservation-related ischemic injury. Tc-NGA also demonstrated focal areas of hepatic infarction in a hepatic allograft within 24 hours of transplantation. The hepatic artery ligation study showed massive changes in the hepatic time-activity curve within two hours after ligation, with a diffuse decrease in hepatic activity. These results indicate that: (1) extrahepatic biliary tract obstruction causes only minor changes in Tc-NGA uptake; (2) Tc-NGA uptake by the liver is very sensitive to acute hepatic ischemia; (3) Tc-NGA may indicate the presence of preservation damage in the early postoperative period; and (4) Tc-NGA hepatic time-activity curves demonstrate significant changes during acute rejection.« less

  4. Tracer attenuation in groundwater

    NASA Astrophysics Data System (ADS)

    Cvetkovic, Vladimir

    2011-12-01

    The self-purifying capacity of aquifers strongly depends on the attenuation of waterborne contaminants, i.e., irreversible loss of contaminant mass on a given scale as a result of coupled transport and transformation processes. A general formulation of tracer attenuation in groundwater is presented. Basic sensitivities of attenuation to macrodispersion and retention are illustrated for a few typical retention mechanisms. Tracer recovery is suggested as an experimental proxy for attenuation. Unique experimental data of tracer recovery in crystalline rock compare favorably with the theoretical model that is based on diffusion-controlled retention. Non-Fickian hydrodynamic transport has potentially a large impact on field-scale attenuation of dissolved contaminants.

  5. Efficacy of (99m)Tc-EDDA/HYNIC-TOC SPECT/CT scintigraphy in Graves' ophthalmopathy.

    PubMed

    Zhao, Rong; Wang, Jiang; Deng, Jinglan; Yang, Weidong; Wang, Jing

    2012-01-01

    The aim of this study was to investigate the predictive role of the orbital somatostatin receptor scintigraphy with (99m)Tc-EDDA/HYNIC-TOC ((99m)Tc-TOC) to detect clinical stage of Graves' ophthalmopathy and the response to corticosteroid therapy. The subjects of the experiment were 46 patients with Graves' ophthalmopathy (GO) and four volunteers without eye disease or GO as the normal group (NG). Single photon emission computed tomography (SPECT), computed tomography (CT) and the left and right lateral position planar imaging of the heads of the all subjects were obtained 4 h after the intravenous injection of 555 MBq of (99m)Tc-TOC. The (99m)Tc-TOC SPECT/CT was repeated 3 months later. 35 (35/46) patients were received corticosteroid therapy (prednisolone, 10 mg po tid ) for 3 months, however, the other 11 patients as control groups did not receive any treatment. The treatment effect was evaluated both by the orbital (99m)Tc-TOC uptake and NOSPECS. A significant decrease in the O/OC ratio was observed in 22 GO patients between pre- and post-treatment (1.64 ± 0.13 vs. 1.21 ± 0.09, P < 0.05). There were neither significant difference of the O/OC ratio in 13 GO patients between pre- and post-treatment periods, nor significant difference in the 9 (9/11) patients before and after three months. Orbital (99m)Tc-TOC scintigraphy is a feasible technique to estimate the Graves' ophthalmopathy activity and predict the response to subsequent corticosteroid therapy in GO patients. The technique could be a useful tool for physicians not familiar with CAS determination.

  6. Efficacy of 99mTc-EDDA/HYNIC-TOC SPECT/CT scintigraphy in Graves’ ophthalmopathy

    PubMed Central

    Zhao, Rong; Wang, Jiang; Deng, Jinglan; Yang, Weidong; Wang, Jing

    2012-01-01

    The aim of this study was to investigate the predictive role of the orbital somatostatin receptor scintigraphy with 99mTc-EDDA/HYNIC-TOC (99mTc-TOC) to detect clinical stage of Graves’ ophthalmopathy and the response to corticosteroid therapy. The subjects of the experiment were 46 patients with Graves’ ophthalmopathy (GO) and four volunteers without eye disease or GO as the normal group (NG). Single photon emission computed tomography (SPECT), computed tomography (CT) and the left and right lateral position planar imaging of the heads of the all subjects were obtained 4 h after the intravenous injection of 555 MBq of 99mTc-TOC. The 99mTc-TOC SPECT/CT was repeated 3 months later. 35 (35/46) patients were received corticosteroid therapy (prednisolone, 10 mg po tid ) for 3 months, however, the other 11 patients as control groups did not receive any treatment. The treatment effect was evaluated both by the orbital 99mTc-TOC uptake and NOSPECS. A significant decrease in the O/OC ratio was observed in 22 GO patients between pre- and post-treatment (1.64 ± 0.13 vs. 1.21 ± 0.09, P < 0.05). There were neither significant difference of the O/OC ratio in 13 GO patients between pre- and post-treatment periods, nor significant difference in the 9 (9/11) patients before and after three months. Orbital 99mTc-TOC scintigraphy is a feasible technique to estimate the Graves’ ophthalmopathy activity and predict the response to subsequent corticosteroid therapy in GO patients. The technique could be a useful tool for physicians not familiar with CAS determination. PMID:23133815

  7. Interpreting tracer breakthrough tailing from different forced-gradient tracer experiment configurations in fractured bedrock

    USGS Publications Warehouse

    Becker, M.W.; Shapiro, A.M.

    2003-01-01

    Conceptual and mathematical models are presented that explain tracer breakthrough tailing in the absence of significant matrix diffusion. Model predictions are compared to field results from radially convergent, weak-dipole, and push-pull tracer experiments conducted in a saturated crystalline bedrock. The models are based upon the assumption that flow is highly channelized, that the mass of tracer in a channel is proportional to the cube of the mean channel aperture, and the mean transport time in the channel is related to the square of the mean channel aperture. These models predict the consistent -2 straight line power law slope observed in breakthrough from radially convergent and weak-dipole tracer experiments and the variable straight line power law slope observed in push-pull tracer experiments with varying injection volumes. The power law breakthrough slope is predicted in the absence of matrix diffusion. A comparison of tracer experiments in which the flow field was reversed to those in which it was not indicates that the apparent dispersion in the breakthrough curve is partially reversible. We hypothesize that the observed breakthrough tailing is due to a combination of local hydrodynamic dispersion, which always increases in the direction of fluid velocity, and heterogeneous advection, which is partially reversed when the flow field is reversed. In spite of our attempt to account for heterogeneous advection using a multipath approach, a much smaller estimate of hydrodynamic dispersivity was obtained from push-pull experiments than from radially convergent or weak dipole experiments. These results suggest that although we can explain breakthrough tailing as an advective phenomenon, we cannot ignore the relationship between hydrodynamic dispersion and flow field geometry at this site. The design of the tracer experiment can severely impact the estimation of hydrodynamic dispersion and matrix diffusion in highly heterogeneous geologic media.

  8. Improvement of High-Resolution Tropical Cyclone Structure and Intensity Forecasts using COAMPS-TC

    DTIC Science & Technology

    2012-09-30

    techniques, as well as observational results from the scientific community including the recent T- PARC /TCS08 and ITOP field campaigns to build upon the...real-time COAMPS-TC forecast for the recent Hurricane Irene is shown in Figure 2. The composite National Weather Service radar reflectivity is shown in...the top panel near the time of landfall in North Carolina at 1148 UTC 27 August 2011 and the COAMPS-TC predicted radar reflectivity at 36 h valid

  9. Technical Note: Coupling of chemical processes with the Modular Earth Submodel System (MESSy) submodel TRACER

    NASA Astrophysics Data System (ADS)

    Jöckel, P.; Kerkweg, A.; Buchholz-Dietsch, J.; Tost, H.; Sander, R.; Pozzer, A.

    2008-03-01

    The implementation of processes related to chemistry into Earth System Models and their coupling within such systems requires the consistent description of the chemical species involved. We provide a tool (written in Fortran95) to structure and manage information about constituents, hereinafter referred to as tracers, namely the Modular Earth Submodel System (MESSy) generic (i.e., infrastructure) submodel TRACER. With TRACER it is possible to define a multitude of tracer sets, depending on the spatio-temporal representation (i.e., the grid structure) of the model. The required information about a specific chemical species is split into the static meta-information about the characteristics of the species, and its (generally in time and space variable) abundance in the corresponding representation. TRACER moreover includes two submodels. One is TRACER_FAMILY, an implementation of the tracer family concept. It distinguishes between two types: type-1 families are usually applied to handle strongly related tracers (e.g., fast equilibrating species) for a specific process (e.g., advection). In contrast to this, type-2 families are applied for tagging techniques. Tagging means the artificial decomposition of one or more species into parts, which are additionally labelled (e.g., by the region of their primary emission) and then processed as the species itself. The type-2 family concept is designed to conserve the linear relationship between the family and its members. The second submodel is TRACER_PDEF, which corrects and budgets numerical negative overshoots that arise in many process implementations due to the numerical limitations (e.g., rounding errors). The submodel therefore guarantees the positive definiteness of the tracers and stabilises the integration scheme. As a by-product, it further provides a global tracer mass diagnostic. Last but not least, we present the submodel PTRAC, which allows the definition of tracers via a Fortran95 namelist, as a complement to

  10. Wanted: Scalable Tracers for Diffusion Measurements

    PubMed Central

    2015-01-01

    Scalable tracers are potentially a useful tool to examine diffusion mechanisms and to predict diffusion coefficients, particularly for hindered diffusion in complex, heterogeneous, or crowded systems. Scalable tracers are defined as a series of tracers varying in size but with the same shape, structure, surface chemistry, deformability, and diffusion mechanism. Both chemical homology and constant dynamics are required. In particular, branching must not vary with size, and there must be no transition between ordinary diffusion and reptation. Measurements using scalable tracers yield the mean diffusion coefficient as a function of size alone; measurements using nonscalable tracers yield the variation due to differences in the other properties. Candidate scalable tracers are discussed for two-dimensional (2D) diffusion in membranes and three-dimensional diffusion in aqueous solutions. Correlations to predict the mean diffusion coefficient of globular biomolecules from molecular mass are reviewed briefly. Specific suggestions for the 3D case include the use of synthetic dendrimers or random hyperbranched polymers instead of dextran and the use of core–shell quantum dots. Another useful tool would be a series of scalable tracers varying in deformability alone, prepared by varying the density of crosslinking in a polymer to make say “reinforced Ficoll” or “reinforced hyperbranched polyglycerol.” PMID:25319586

  11. Redesigning TRACER trial after TRITON.

    PubMed

    Serebruany, Victor L

    2015-10-15

    Designing of smart clinical trials is critical for regulatory approval and future drug utilization. Importantly, trial design should be reconsidered if the interim analyses suggest unexpected harm, or conflicting results were yielded from the other trials within the same therapeutic area. With regard to antiplatelet agents, the perfect example is redesigning of the ongoing PRoFESS trial by eliminating aspirin from clopidogrel arm after the earlier MATCH trial results became available. The goal was to aseess the unchanged TRACER trial design in light of the evidence yielded from the earlier completed TRITON trial. TRACER was designed as a triple versus dual antiplatelet trial in NSTEMI patients with no previous long-term outcome data supporting such aggressive strategy. TRITON data represented dual versus dual antiplatelet therapy, and became available before TRACER enrollment starts revealing prasugrel front-loaded early vascular benefit predominantly in STEMI patients with the growing over time bleeding and cancer risks. Moreover, large prasugrel NSTEMI TRITON cohort exhibited trend towards excess mortality in experimental arm warning against aggressive TRACER design. The long-term TRITON results in general, and especially in the NSTEMI patients challenge unchanged TRACER trial design. Applying dual, rather than triple antiplatelet therapy protocol modification should be considered in TRACER to minimize bleeding, cancer, and non-cardiovascular death risks. Copyright © 2015. Published by Elsevier Ireland Ltd.

  12. Long residence times - bad tracer tests?

    NASA Astrophysics Data System (ADS)

    Ghergut, Julia; Behrens, Horst; Sauter, Martin

    2015-04-01

    Tracer tests conducted at geothermal well doublets or triplets in the Upper Rhine Rift Valley [1] all face, with very few exceptions so far, one common issue: lack of conclusive tracer test results, or tracer signals still undetectable for longer than one or two years after tracer injection. While the reasons for this surely differ from site to site (Riehen, Landau, Insheim, Bruchsal, ...), its effects on how the usefulness of tracer tests is perceived by the non-tracer community are pretty much the same. The 'poor-signal' frustration keeps nourishing two major 'alternative' endeavours : (I) design and execute tracer tests in single-well injection-withdrawal (push-pull), 'instead of' inter-well flow-path tracing configurations; (II) use 'novel' tracer substances instead of the 'old' ones which have 'obviously failed'. Frustration experienced with most inter-well tracer tests in the Upper Rhine Rift Valley has also made them be regarded as 'maybe useful for EGS' ('enhanced', or 'engineered' geothermal systems, whose fluid RTD typically include a major share of values below one year), but 'no longer worthwhile a follow-up sampling' in natural, large-scale hydrothermal reservoirs. We illustrate some of these arguments with the ongoing Bruchsal case [2]. The inter-well tracer test conducted at Bruchsal was (and still is!) aimed at assessing inter-well connectivity, fluid residence times, and characterizing the reservoir structure [3]. Fluid samples taken at the geothermal production well after reaching a fluid turnover of about 700,000 m3 showed tracer concentrations in the range of 10-8 Minj per m3, in the liquid phase of each sample (Minj being the total quantity of tracer injected as a short pulse at the geothermal re-injection well). Tracer signals might actually be higher, owing to tracer amounts co-precipitated and/or adsorbed onto the solid phase whose accumulation in the samples was unavoidable (due to pressure relief and degassing during the very sampling

  13. Properties of an ideal PET perfusion tracer: new PET tracer cases and data.

    PubMed

    Maddahi, Jamshid

    2012-02-01

    An ideal positron emission tomography (PET) tracer should be highly extractable by the myocardium and able to provide high-resolution images, should enable quantification of absolute myocardial blood flow (MBF), should be compatible with both pharmacologically induced and exercise-induced stress imaging, and should not require an on-site cyclotron. The PET radionuclides nitrogen-13 ammonia and oxygen-15 water require an on-site cyclotron. Rubidium-82 may be available locally due to the generator source, but greater utilization is limited because of its relatively low myocardial extraction fraction, long positron range, and generator cost. Flurpiridaz F 18, a novel PET tracer in development, has a high-extraction fraction, short positron range, and relatively long half-life (as compared to currently available tracers), and may be produced at regional cyclotrons. Results of early clinical trials suggest that both pharmacologically and exercise-induced stress PET imaging protocols can be completed more rapidly and with lower patient radiation exposure than with single-photon emission computerized tomography (SPECT) tracers. As compared to SPECT images in the same patients, flurpiridaz F 18 PET images showed better defect contrast. Flurpiridaz F 18 is a potentially promising tracer for assessment of myocardial perfusion, measurement of absolute MBF, calculation of coronary flow reserves, and assessment of cardiac function at the peak of the stress response.

  14. Olanzapine induced Q-Tc shortening.

    PubMed

    Shoja Shafti, Saeed; Fallah Jahromi, Parisa

    2014-12-01

    Prolongation of Q-Tc interval is commonly accepted as a surrogate marker for the ability of a drug to cause torsade de pointes. In the present study, safety of olanzapine versus risperidone was compared among a group of patients with schizophrenia to see the frequency of the electrocardiographic alterations induced by those atypical antipsychotics. Two hundred and sixty-eight female inpatients with schizophrenia entered in one of the two parallel groups to participate in an open study for random assignment to olanzapine (n = 148) or risperidone (n = 120). Standard 12-lead surface electrocardiogram (ECG) was taken from each patient at baseline, before initiation of treatment, and then at the end of management, just before discharge. The parameters that were assessed included heart rate (HR), P-R interval, QRS interval, Q-T interval (corrected = Q-Tc), ventricular activation time (VAT), ST segment, T wave, axis of QRS, and finally, interventricular conduction process. A total of 37.83% of cases in the olanzapine group and 30% in the risperidone group showed some Q-Tc changes; 13.51% and 24.32% of the patients in the olanzapine group showed prolongation and shortening of the Q-Tc, respectively, while changes in the risperidone group were restricted to only prolongation of Q-Tc. Comparison of means showed a significant increment in Q-Tc by risperidone (p = 0.02). Also, comparison of proportions in the olanzapine group showed significantly more cases with shortening of Q-Tc versus its prolongation (p = 0.01). No significant alterations with respect to other variables were evident. Olanzapine and risperidone had comparable potentiality for induction of Q-Tc changes, while production of further miscellaneous alterations in ECG was more observable in the olanzapine group compared with the risperidone group. Also shortening of Q-Tc was specific to olanzapine.

  15. Preclinical evaluation of (99m)Tc labeled chondroitin sulfate for monitoring of cartilage degeneration in osteoarthritis.

    PubMed

    Sobal, Grazyna; Velusamy, Kavitha; Kosik, Siegfried; Menzel, Johannes; Hacker, Marcus; Pagitz, Maximilian

    2016-06-01

    In previous in-vitro and ex-vivo studies we proved the specific uptake of (99m)Tc radiolabeled chondroitin sulfate (CS) in human articular cartilage. As a logical next step for the clinical use for imaging osteoarthritis we investigated in-vivo uptake of (99m)TcCS in dogs. The radiolabeling of CS Condrosulf (IBSA, Lugano, Switzerland) was performed using 25mg of CS and 20-40MBq/kg body weight of (99m)Tc by means of the tin method. In-vivo uptake of (99m)TcCS was evaluated in dogs (n=12, castrated males, 4-9years, with 15-51kg body weight). 6 healthy dogs served as controls and 6 with clinical and radiological signs of osteoarthritis in the carpal, elbow, and tarsal joint were examined. The tracer was i.v. injected into the external cephalic vein. The uptake was monitored after 2, 4, 6 and 24h in healthy and osteoarthritic dogs using a planar gamma camera by regional planar or whole body ventral and dorsal acquisition. For whole body scintigraphy animals were under general anesthesia, for planar under sedation only. In healthy control dogs we did not detect any specific uptake of (99m)TcCS in the cartilage. In contrast, in the diseased dogs suffering from osteoarthritis a significant, specific, persistent uptake between 4 and 6h in tarsal, carpal and cubital joints was documented. Median target (joint) to background (mid antebrachium) ratio (T/B) in the OA joints after 4, 6, and 24h was significantly higher than in healthy controls. Target to background ratio using soft tissue as a background (T/S) a similar significantly higher than in healthy controls. In all osteoarthritic joints we found a significant positive correlation (r=0.8, n=20) between grade of disease (I-III) and T/B. When matching radiographic (X ray) changes in osteoarthritic joints (grade II and III) we found also a maximal uptake of (99m)TcCS at the specific anatomical site of highest cartilage degeneration. None of the dogs experienced any side effects. These results suggest that (99m)TcCS might

  16. Transport and dispersion of fluorescent tracer particles for the dune-bed condition, Atrisco Feeder Canal near Bernalillo, New Mexico

    USGS Publications Warehouse

    Rathbun, R.E.; Kennedy, Vance C.

    1978-01-01

    A fluorescent tracer technique was used to study the rates of transport and dispersion of sediment particles of various diameters and specific gravities for a dune-bed condition in an alluvial channel, Atrisco Feeder Canal near Bernalillo, N. Mex. The total transport rates of bed material measured by the steady-dilution and spatial-integration procedures were within the range of transport rates computed by the modified Einstein procedure. Lateral dispersion of the tracer particles increased with increase in the size of the tracer particles, whereas longitudinal dispersion decreased. The velocities of the tracer particles decreased with increase in the size of the tracer particles; dependence on particle diameter was large for the small particles, small for the large particles. Tracers were found at larger depths in the bed than would be expected on the basis of the sizes of the dunes in the channel. (Woodard-USGS)

  17. Statistically Based Morphodynamic Modeling of Tracer Slowdown

    NASA Astrophysics Data System (ADS)

    Borhani, S.; Ghasemi, A.; Hill, K. M.; Viparelli, E.

    2017-12-01

    Tracer particles are used to study bedload transport in gravel-bed rivers. One of the advantages associated with using of tracer particles is that they allow for direct measures of the entrainment rates and their size distributions. The main issue in large scale studies with tracer particles is the difference between tracer stone short term and long term behavior. This difference is due to the fact that particles undergo vertical mixing or move to less active locations such as bars or even floodplains. For these reasons the average virtual velocity of tracer particle decreases in time, i.e. the tracer slowdown. In summary, tracer slowdown can have a significant impact on the estimation of bedload transport rate or long term dispersal of contaminated sediment. The vast majority of the morphodynamic models that account for the non-uniformity of the bed material (tracer and not tracer, in this case) are based on a discrete description of the alluvial deposit. The deposit is divided in two different regions; the active layer and the substrate. The active layer is a thin layer in the topmost part of the deposit whose particles can interact with the bed material transport. The substrate is the part of the deposit below the active layer. Due to the discrete representation of the alluvial deposit, active layer models are not able to reproduce tracer slowdown. In this study we try to model the slowdown of tracer particles with the continuous Parker-Paola-Leclair morphodynamic framework. This continuous, i.e. not layer-based, framework is based on a stochastic description of the temporal variation of bed surface elevation, and of the elevation specific particle entrainment and deposition. Particle entrainment rates are computed as a function of the flow and sediment characteristics, while particle deposition is estimated with a step length formulation. Here we present one of the first implementation of the continuum framework at laboratory scale, its validation against

  18. Asian Tracer Experiment and Atmospheric Modeling (TEAM) Project: Draft Field Work Plan for the Asian Long-Range Tracer Experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Allwine, K Jerry; Flaherty, Julia E.

    2007-08-01

    This report provides an experimental plan for a proposed Asian long-range tracer study as part of the international Tracer Experiment and Atmospheric Modeling (TEAM) Project. The TEAM partners are China, Japan, South Korea and the United States. Optimal times of year to conduct the study, meteorological measurements needed, proposed tracer release locations, proposed tracer sampling locations and the proposed durations of tracer releases and subsequent sampling are given. Also given are the activities necessary to prepare for the study and the schedule for completing the preparation activities leading to conducting the actual field operations. This report is intended to providemore » the TEAM members with the information necessary for planning and conducting the Asian long-range tracer study. The experimental plan is proposed, at this time, to describe the efforts necessary to conduct the Asian long-range tracer study, and the plan will undoubtedly be revised and refined as the planning goes forward over the next year.« less

  19. Measurement of pulmonary epithelial permeability with /sup 99m/Tc-DTPA aerosol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coates, G.; O'Brodovich, H.

    1986-10-01

    The rate at which inhaled aerosol of /sup 99m/Tc-diethylenetriamine pentaacetate (DTPA) leaves the lung by diffusion into the vascular space can be measured with a gamma camera or simple probe. In normal humans, /sup 99m/Tc-DTPA clears from the lung with a half time of about 80 minutes. Many acute and chronic conditions that alter the integrity of the pulmonary epithelium cause an increased clearance rate. Thus cigarette smoking, alveolitis from a variety of causes, adult respiratory distress syndrome (ARDS), and hyaline membrane disease (HMD) in the infant have all been shown to be associated with rapid pulmonary clearance of /supmore » 99m/Tc-DTPA. Rapid clearance is also promoted by increased lung volume and decreased surfactant activity. Although the mechanism of increased clearance in pathological states is not known, the /sup 99m/Tc-DTPA lung-clearance technique has great potential clinically, particularly in patients at risk from ARDS and HMD and in the diagnosis and follow-up of alveolitis. 58 references.« less

  20. Inverse correlation between quasiparticle mass and Tc in a cuprate high-Tc superconductor

    PubMed Central

    Putzke, Carsten; Malone, Liam; Badoux, Sven; Vignolle, Baptiste; Vignolles, David; Tabis, Wojciech; Walmsley, Philip; Bird, Matthew; Hussey, Nigel E.; Proust, Cyril; Carrington, Antony

    2016-01-01

    Close to a zero-temperature transition between ordered and disordered electronic phases, quantum fluctuations can lead to a strong enhancement of electron mass and to the emergence of competing phases such as superconductivity. A correlation between the existence of such a quantum phase transition and superconductivity is quite well established in some heavy fermion and iron-based superconductors, and there have been suggestions that high-temperature superconductivity in copper-oxide materials (cuprates) may also be driven by the same mechanism. Close to optimal doping, where the superconducting transition temperature Tc is maximal in cuprates, two different phases are known to compete with superconductivity: a poorly understood pseudogap phase and a charge-ordered phase. Recent experiments have shown a strong increase in quasiparticle mass m* in the cuprate YBa2Cu3O7-δ as optimal doping is approached, suggesting that quantum fluctuations of the charge-ordered phase may be responsible for the high-Tc superconductivity. We have tested the robustness of this correlation between m* and Tc by performing quantum oscillation studies on the stoichiometric compound YBa2Cu4O8 under hydrostatic pressure. In contrast to the results for YBa2Cu3O7-δ, we find that in YBa2Cu4O8, the mass decreases as Tc increases under pressure. This inverse correlation between m* and Tc suggests that quantum fluctuations of the charge order enhance m* but do not enhance Tc. PMID:27034989

  1. Molecular and biochemical characterisation of two aspartic proteinases TcAP1 and TcAP2 from Theobroma cacao seeds.

    PubMed

    Laloi, Maryse; McCarthy, James; Morandi, Olivia; Gysler, Christof; Bucheli, Peter

    2002-09-01

    Aspartic proteinase (EC 3.4.23) activity plays a pivotal role in the degradation of Theobroma cacao L. seed proteins during the fermentation step of cacao bean processing. Therefore, this enzyme is believed to be critical for the formation of the peptide and amino acid cocoa flavor precursors that occurs during fermentation. Using cDNA cloning and northern blot analysis, we show here that there are at least two distinct aspartic proteinase genes ( TcAP1 and TcAP2) expressed during cacao seed development. Both genes are expressed early during seed development and their mRNA levels decrease towards the end of seed maturation. TcAP2 is expressed at a much higher level than TcAP1, although the expression of TcAP1 increases slightly during germination. The proteins encoded by TcAP1 and TcAP2 are relatively different from each other (73% identity). This, and the fact that the two corresponding genes have different expression patterns, suggests that the TcAP1 and TcAP2 proteins may have different functions in the maturing seeds and during germination. Because the TcAP2 gene is expressed at a much higher level during seed development than TcAP1, it is likely that the TcAP2 protein is primarily responsible for the majority of the industrially important protein hydrolysis that occurs during cacao bean fermentation. Finally, TcAP2 has been functionally expressed in the yeast Yarrowia lipolytica. The secreted recombinant protein is able to hydrolyse bovine haemoglobin at acidic pH and is sensitive to pepstatin A, confirming that TcAP2 encodes an aspartic proteinase, and strongly suggests that this gene encodes the well-characterized aspartic proteinase of mature cacao seeds.

  2. Effects of FlAsH/Tetracysteine (TC) tag on PrP proteolysis and PrPres formation by TC-scanning

    PubMed Central

    Taguchi, Yuzuru; Hohsfield, Lindsay A.; Hollister, Jason R.

    2014-01-01

    The FlAsH/tetracysteine (FlAsH/TC) tag is a powerful tool for fluorescent labeling of proteins. However, even small tags such as FlAsH/TC could alter the behavior of the tagged proteins, especially if the insertion occurs at internal sites. Defining the influence of FlAsH/TC on nearby protein-protein interactions might aid in selecting appropriate positions for internal TC insertions and allow the exploitation of serial FlAsH/TC insertions (TC-scanning) as a probe to characterize sites of protein-protein interaction. To explore this application in the context of substrate-protease interactions, we analyzed the effect of FlAsH/TC insertions on proteolysis of cellular prion protein (PrPsen) in in vitro reactions and generation of the C1 metabolic fragment of PrPsen in live neuroblastoma cells. The influence of FlAsH/TC insertion was evaluated by TC-scanning across the cleavage sites of each protease. The results showed that FlAsH/TC inhibited protease cleavage only within limited ranges of the cleavage sites that varied from about 1 to 6 residues-wide depending on the protease, providing an estimate of the PrP residues interacting with each protease. TC-scanning was also used to probe a different type of protein-protein interaction, the conformational conversion of FlAsH-PrPsen to the prion disease-associated isoform, PrPres. PrP constructs with FlAsH/TC insertions at residues 90–96 but not 97–101 were converted to FlAsH-PrPres, identifying a boundary separating loosely versus compactly folded regions of PrPres. Our observations demonstrate that TC-scanning with the FlAsH/TC tag can be a versatile method for probing protein-protein interactions and folding processes. PMID:23943295

  3. Measuring self-pollution in school buses using a tracer gas technique

    NASA Astrophysics Data System (ADS)

    Behrentz, Eduardo; Fitz, Dennis R.; Pankratz, David V.; Sabin, Lisa D.; Colome, Steven D.; Fruin, Scott A.; Winer, Arthur M.

    A potentially important, but inadequately studied, source of children's exposure to pollutants during school bus commutes is the introduction of a bus's own exhaust into the passenger compartment. We developed and applied a method to determine the amount of a bus's own exhaust penetrating into the cabin in a study of six in-use school buses over a range of routes, roadway types, fuels, and emission control technologies. A tracer gas, SF 6, was metered into the bus's exhaust system using a mass flow controller whose flow rate was logged by a data acquisition system and processed with the concurrent real-time pollutant measurement data. At the same time, the SF 6 concentration inside the bus was measured using an AeroVironment CTA-1000 continuous analyzer connected to a series of solenoids that switched the sample inlet between the front and rear of the bus cabin. To account for a baseline drift of the CTA-1000, SF 6-free air was also drawn through a line located outside at the front of the bus. Although this third sample line generally provided a reference zero value, it also showed that under certain wind conditions (i.e., wind from the rear) when the bus was stopped and was idling, significant amounts of the bus's own exhaust reached this location at the front of the bus. Self-pollution, the percentage of a bus's own exhaust that can be found inside its cabin, was a function of bus type and age, and a strong function of window position (i.e., open or closed). We estimated up to 0.3% of the air inside the cabin was from the bus's own exhaust in older buses, approximately 10 times the percentage observed for newer buses, and 25% of the black carbon concentration variance was explained by the buses' self-pollution. Analysis of the tracer gas concentrations provided a powerful tool for identifying potentially high-exposure conditions.

  4. Development of a multispectral autoradiography using a coded aperture

    NASA Astrophysics Data System (ADS)

    Noto, Daisuke; Takeda, Tohoru; Wu, Jin; Lwin, Thet T.; Yu, Quanwen; Zeniya, Tsutomu; Yuasa, Tetsuya; Hiranaka, Yukio; Itai, Yuji; Akatsuka, Takao

    2000-11-01

    Autoradiography is a useful imaging technique to understand biological functions using tracers including radio isotopes (RI's). However, it is not easy to describe the distribution of different kinds of tracers simultaneously by conventional autoradiography using X-ray film or Imaging plate. Each tracer describes each corresponding biological function. Therefore, if we can simultaneously estimate distribution of different kinds of tracer materials, the multispectral autoradiography must be a quite powerful tool to better understand physiological mechanisms of organs. So we are developing a system using a solid state detector (SSD) with high energy- resolution. Here, we introduce an imaging technique with a coded aperture to get spatial and spectral information more efficiently. In this paper, the imaging principle is described, and its validity and fundamental property are discussed by both simulation and phantom experiments with RI's such as 201Tl, 99mTc, 67Ga, and 123I.

  5. A DNA Tracer System for Hydrological Environment Investigations.

    PubMed

    Liao, Renkuan; Yang, Peiling; Wu, Wenyong; Luo, Dan; Yang, Dayong

    2018-02-20

    To monitor and manage hydrological pollution effectively, tracing sources of pollutants is of great importance and also is in urgent need. A variety of tracers have been developed such as isotopes, silica, bromide, and dyes; however, practical limitations of these traditional tracers still exist such as lack of multiplexed, multipoint tracing and interference of background noise. To overcome these limitations, a new tracing system based on DNA nanomaterials, namely DNA tracer, has already been developed. DNA tracers possess remarkable advantages including sufficient species, specificity, environmental friendly, stable migration, and high sensitivity as well as allowing for multipoints tracing. In this review article, we introduce the molecular design, synthesis, protection and signal readout strategies of DNA tracers, compare the advantages and disadvantages of DNA tracer with traditional tracers, and summarize the-state-of-art applications in hydrological environment investigations. In the end, we provide our perspective on the future development of DNA tracers.

  6. Telecom 2-B and 2-C (TC2B and TC2C)

    NASA Technical Reports Server (NTRS)

    Dulac, J.; Alvarez, H.

    1991-01-01

    The DSN (Deep Space Network) mission support requirements for Telecom 2-B and 2-C (TC2B and TC2C) are summarized. These Telecom missions will provide high-speed data link applications, telephone, and television service between France and overseas territories as a follow-on to TC2A. Mission objectives are outlined and the DSN support requirements are defined through the presentation of tables and narratives describing the spacecraft flight profile; DSN support coverage; frequency assignments; support parameters for telemetry, command and support systems; and tracking support responsibility.

  7. Trypanosoma cruzi diversity in the Gran Chaco: mixed infections and differential host distribution of TcV and TcVI.

    PubMed

    Monje-Rumi, María M; Brandán, Cecilia Pérez; Ragone, Paula G; Tomasini, Nicolás; Lauthier, Juan J; Alberti D'Amato, Anahí M; Cimino, Rubén O; Orellana, Viviana; Basombrío, Miguel A; Diosque, Patricio

    2015-01-01

    The transmission cycles of Trypanosoma cruzi in the Gran Chaco are complex networks involving domestic and wild components, whose interrelationships are not well understood. Knowing the circuit of transmission of the different Discrete Typing Units (DTUs) of T. cruzi in the complex environment of the Chaco region is relevant to understanding how the different components (reservoirs, vectors, ecotopes) interact. In the present study we identified the DTUs infecting humans and dogs in two rural areas of the Gran Chaco in Argentina, using molecular methods which avoid parasite culture. Blood samples of humans and dogs were typified by PCR-DNA blotting and hybridization assays with five specific DNA probes (TcI, TcII, TcIII, TcV and TcVI). PCR analyses were performed on seropositive human and dog samples and showed the presence of T. cruzi DNA in 41.7% (98/235) and 53% (35/66) samples, respectively. The identification of infective DTUs was determined in 83.6% (82/98) and 91.4% (32/35) in human and dog samples, respectively. Single infections (36.7% - 36/98) and a previously not detected high proportion of mixed infections (47.9% - 47/98) were found. In a 15.3% (15/98) of samples the infecting DTU was not identified. Among the single infections TcV was the most prevalent DTU (30.6% - 30/98) in human samples; while TcVI (42.8% - 15/35) showed the highest prevalence in dog samples. TcV/TcVI was the most prevalent mixed infection in humans (32.6% - 32/98); and TcI/TcVI (14.3% - 5/35) in dogs. Significant associations between TcV with humans and TcVI with dogs were detected. For the first time, the presence of TcIII was detected in humans from this region. The occurrence of one human infected whit TcIII (a principally wild DTU) could be suggested the emergence of this, in domestic cycles in the Gran Chaco. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Sentinel lymph node detection in early cervical cancer with combination 99mTc phytate and patent blue.

    PubMed

    Niikura, Hitoshi; Okamura, Chikako; Akahira, Junichi; Takano, Tadao; Ito, Kiyoshi; Okamura, Kunihiro; Yaegashi, Nobuo

    2004-08-01

    The purpose of this study was to examine sentinel lymph node (SLN) detection in patients with early stage cervical cancer using (99m)Tc phytate and patent blue dye and to compare our method with published findings utilizing other radioisotopic tracers. A total of 20 consecutive patients with cervical cancer scheduled for radical hysterectomy and total pelvic lymphadenectomy at our hospital underwent SLN detection study. The day before surgery, lymphoscintigraphy was performed with injection of 99m-technetium ((99m)Tc)-labeled phytate into the uterine cervix. At surgery, patients underwent lymphatic mapping with a gamma-detecting probe and patent blue injected into the same points as the phytate solution. At least one positive node was detected in 18 patients (90%). A total of 46 sentinel nodes were detected (mean, 2.3; range, 1-5). Most sentinel nodes were in one of the following sites: external iliac (21 nodes), obturator (15 nodes), and parametrial (7 nodes). Eleven (24%) sentinel nodes were detected only through radioactivity and two (4%) were detected only with blue dye. The sensitivity, specificity, and negative predictive value for SLN detection were all 100%. Nine published studies involving 295 patients had a summarized detection rate of 85%. Summarized sensitivity, specificity, and negative predictive value were 93%, 100%, and 99%, respectively. Combination of (99m)Tc phytate and patent blue is effective in SLN detection in early stage cervical cancer.

  9. A New Kind of Single-Well Tracer Test for Assessing Subsurface Heterogeneity

    NASA Astrophysics Data System (ADS)

    Hansen, S. K.; Vesselinov, V. V.; Lu, Z.; Reimus, P. W.; Katzman, D.

    2017-12-01

    Single-well injection-withdrawal (SWIW) tracer tests have historically been interpreted using the idealized assumption of tracer path reversibility (i.e., negligible background flow), with background flow due to natural hydraulic gradient being an un-modeled confounding factor. However, we have recently discovered that it is possible to use background flow to our advantage to extract additional information about the subsurface. To wit: we have developed a new kind of single-well tracer test that exploits flow due to natural gradient to estimate the variance of the log hydraulic conductivity field of a heterogeneous aquifer. The test methodology involves injection under forced gradient and withdrawal under natural gradient, and makes use of a relationship, discovered using a large-scale Monte Carlo study and machine learning techniques, between power law breakthrough curve tail exponent and log-hydraulic conductivity variance. We will discuss how we performed the computational study and derived this relationship and then show an application example in which our new single-well tracer test interpretation scheme was applied to estimation of heterogeneity of a formation at the chromium contamination site at Los Alamos National Laboratory. Detailed core hole records exist at the same site, from which it was possible to estimate the log hydraulic conductivity variance using a Kozeny-Carman relation. The variances estimated using our new tracer test methodology and estimated by direct inspection of core were nearly identical, corroborating the new methodology. Assessment of aquifer heterogeneity is of critical importance to deployment of amendments associated with in-situ remediation strategies, since permeability contrasts potentially reduce the interaction between amendment and contaminant. Our new tracer test provides an easy way to obtain this information.

  10. STRATEGIES FOR QUANTIFYING PET IMAGING DATA FROM TRACER STUDIES OF BRAIN RECEPTORS AND ENZYMES.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Logan, J.

    2001-04-02

    A description of some of the methods used in neuroreceptor imaging to distinguish changes in receptor availability has been presented in this chapter. It is necessary to look beyond regional uptake of the tracer since uptake generally is affected by factors other than the number of receptors for which the tracer has affinity. An exception is the infusion method producing an equilibrium state. The techniques vary in complexity some requiring arterial blood measurements of unmetabolized tracer and multiple time uptake data. Others require only a few plasma and uptake measurements and those based on a reference region require no plasmamore » measurements. We have outlined some of the limitations of the different methods. Laruelle (1999) has pointed out that test/retest studies to which various methods can be applied are crucial in determining the optimal method for a particular study. The choice of method will also depend upon the application. In a clinical setting, methods not involving arterial blood sampling are generally preferred. In the future techniques for externally measuring arterial plasma radioactivity with only a few blood samples for metabolite correction will extend the modeling options of clinical PET. Also since parametric images can provide information beyond that of ROI analysis, improved techniques for generating such images will be important, particularly for ligands requiring more than a one-compartment model. Techniques such as the wavelet transform proposed by Turkheimer et al. (2000) may prove to be important in reducing noise and improving quantitation.« less

  11. Selective Imaging of Vascular Endothelial Growth Factor Receptor-1 and Receptor-2 in Atherosclerotic Lesions in Diabetic and Non-diabetic ApoE-/- Mice.

    PubMed

    Tekabe, Yared; Johnson, Lynne L; Rodriquez, Krissy; Li, Qing; Backer, Marina; Backer, Joseph M

    2018-02-01

    Plaque vulnerability is associated with inflammation and angiogenesis, processes that rely on vascular endothelial growth factor (VEGF) signaling via two receptors, VEGFR-1 and VEGFR-2. We have recently reported that enhanced uptake of scVEGF-PEG-DOTA/Tc-99m (scV/Tc) single photon emission computed tomography (SPECT) tracer that targets both VEGFR-1 and VEGFR-2, identifies accelerated atherosclerosis in diabetic relative to non-diabetic ApoE -/- mice. Since VEGFR-1 and VEGFR-2 may play different roles in atherosclerotic plaques, we reasoned that selective imaging of each receptor can provide more detailed information on plaque biology. Recently described VEGFR-1 and VEGFR-2 selective mutants of scVEGF, named scVR1 and scVR2, were site-specifically derivatized with Tc-99m chelator DOTA via 3.4 kDa PEG linker, and their selectivity to the cognate receptors was confirmed in vitro. scVR1 and scVR2 conjugates were radiolabeled with Tc-99m to specific activity of 110 ± 11 MBq/nmol, yielding tracers named scVR1/Tc and scVR2/Tc. 34-40 week old diabetic and age-matched non-diabetic ApoE -/- mice were injected with tracers, 2-3 h later injected with x-ray computed tomography (CT) contrast agent and underwent hybrid SPECT/CT imaging. Tracer uptake, localized to proximal aorta and brachiocephalic vessels, was quantified as %ID from. Tracer uptake was also quantified as %ID/g from gamma counting of harvested plaques. Harvested atherosclerotic arterial tissue was used for immunofluorescent analyses of VEGFR-1 and VEGFR-2 and various lineage-specific markers. Focal, receptor-mediated uptake in proximal aorta and brachiocephalic vessels was detected for both scVR1/Tc and scVR2/Tc tracers. Uptake of scVR1/Tc and scVR2/Tc was efficiently inhibited only by "cold" proteins of the same receptor selectivity. Tracer uptake in this area, expressed as %ID, was higher in diabetic vs. non- diabetic mice for scVR1/Tc (p = 0.01) but not for scVR2/Tc. Immunofluorescent analysis

  12. Comparison of internal dose estimates obtained using organ-level, voxel S value, and Monte Carlo techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grimes, Joshua, E-mail: grimes.joshua@mayo.edu; Celler, Anna

    2014-09-15

    Purpose: The authors’ objective was to compare internal dose estimates obtained using the Organ Level Dose Assessment with Exponential Modeling (OLINDA/EXM) software, the voxel S value technique, and Monte Carlo simulation. Monte Carlo dose estimates were used as the reference standard to assess the impact of patient-specific anatomy on the final dose estimate. Methods: Six patients injected with{sup 99m}Tc-hydrazinonicotinamide-Tyr{sup 3}-octreotide were included in this study. A hybrid planar/SPECT imaging protocol was used to estimate {sup 99m}Tc time-integrated activity coefficients (TIACs) for kidneys, liver, spleen, and tumors. Additionally, TIACs were predicted for {sup 131}I, {sup 177}Lu, and {sup 90}Y assuming themore » same biological half-lives as the {sup 99m}Tc labeled tracer. The TIACs were used as input for OLINDA/EXM for organ-level dose calculation and voxel level dosimetry was performed using the voxel S value method and Monte Carlo simulation. Dose estimates for {sup 99m}Tc, {sup 131}I, {sup 177}Lu, and {sup 90}Y distributions were evaluated by comparing (i) organ-level S values corresponding to each method, (ii) total tumor and organ doses, (iii) differences in right and left kidney doses, and (iv) voxelized dose distributions calculated by Monte Carlo and the voxel S value technique. Results: The S values for all investigated radionuclides used by OLINDA/EXM and the corresponding patient-specific S values calculated by Monte Carlo agreed within 2.3% on average for self-irradiation, and differed by as much as 105% for cross-organ irradiation. Total organ doses calculated by OLINDA/EXM and the voxel S value technique agreed with Monte Carlo results within approximately ±7%. Differences between right and left kidney doses determined by Monte Carlo were as high as 73%. Comparison of the Monte Carlo and voxel S value dose distributions showed that each method produced similar dose volume histograms with a minimum dose covering 90% of the volume

  13. Tc-99m Radiolabeled Peptide p5 + 14 is an Effective Probe for SPECT Imaging of Systemic Amyloidosis.

    PubMed

    Kennel, Stephen J; Stuckey, Alan; McWilliams-Koeppen, Helen P; Richey, Tina; Wall, Jonathan S

    2016-08-01

    Systemic peripheral amyloidosis is a rare disease in which misfolded proteins deposit in various organs. We have previously developed I-124 labeled peptide p5 + 14 as a tracer for positron emission tomography imaging of amyloid in patients. In this report, we now document the labeling efficiency, bioactivity, and stability of Tc-99m labeled p5 + 14 for single-photon emission computed tomography (SPECT) imaging of amyloidosis, validated in a mouse model of systemic amyloidosis. Radiochemical yield, purity, and biological activity of [(99m)Tc]p5 + 14 were documented by instant thin-layer chromatography (ITLC), SDS-PAGE and a quantitative amyloid fibril pulldown assay. The efficacy and stability were documented in serum amyloid protein A (AA) amyloid-bearing or wild-type (WT) control mice imaged with SPECT/X-ray computed tomography (CT) at two time points. The uptake and retention of [(99m)Tc]p5 + 14 in hepatosplenic amyloid was evaluated using region of interest (ROI) and tissue counting measurements. Tc-99m p5 + 14 was produced with a radiochemical yield of 75 % with greater than 90 % purity and biological activity comparable to that of radioiodinated peptide. AA amyloid was visualized by SPECT/CT imaging with specific uptake seen in amyloid-laden organs at levels ∼5 folds higher than in healthy mice. ROI analyses of decay-corrected SPECT/CT images showed <20 % loss of radiolabel from the 1 to 4 h imaging time points. Biodistribution data confirmed the specificity of the probe accumulation by amyloid-laden organs as compared to non-diseased tissues. [(99m)Tc]p5 + 14 is a specific and stable radiotracer for systemic amyloid in mice and may provide a convenient and inexpensive alternative to imaging of peripheral amyloidosis in patients.

  14. (99m)Tc-pyrophosphate scintigraphy for differentiating light-chain cardiac amyloidosis from the transthyretin-related familial and senile cardiac amyloidoses.

    PubMed

    Bokhari, Sabahat; Castaño, Adam; Pozniakoff, Ted; Deslisle, Susan; Latif, Farhana; Maurer, Mathew S

    2013-03-01

    Differentiating immunoglobulin light-chain (AL) from transthyretin-related cardiac amyloidoses (ATTR) is imperative given implications for prognosis, therapy, and genetic counseling. We validated the discriminatory ability of (99m)Tc-pyrophosphate ((99m)Tc-PYP) scintigraphy in AL versus ATTR. Forty-five subjects (12 AL, 16 ATTR wild type, and 17 ATTR mutants) underwent (99m)Tc-PYP planar and single-photon positive emission computed tomography cardiac imaging. Scans were performed by experienced nuclear cardiologists blinded to the subjects' cohort assignment. Cardiac retention was assessed with both a semiquantitative visual score (range, 0; no uptake to 3, diffuse uptake) and by quantitative analysis by drawing a region of interest over the heart corrected for contralateral counts and calculating a heart-to-contralateral ratio. Subjects with ATTR cardiac amyloid had a significantly higher semiquantitative cardiac visual score than the AL cohort (2.9±0.06 versus 0.8±0.27; P<0.0001) as well as a higher quantitative score (1.80±0.04 versus 1.21±0.04; P<0.0001). Using a heart-to-contralateral ratio >1.5 consistent with intensely diffuse myocardial tracer retention had a 97% sensitivity and 100% specificity with area under the curve 0.992, P<0.0001 for identifying ATTR cardiac amyloidosis. (99m)Tc-PYP cardiac imaging distinguishes AL from ATTR cardiac amyloidosis and may be a simple, widely available method for identifying subjects with ATTR cardiac amyloidosis, which should be studied in a larger prospective manner.

  15. Imaging of irradiated liver with Tc-99m-sulfur colloid and Tc-99m-IDA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gelfand, M.J.; Saha, S.; Aron, B.S.

    1981-09-01

    In three cases, irradiated regions of liver failed to concentrate Tc-99m-sulfur colloid. In two of these three, imaging with Tc-99m-acetanilide iminodiacetic acid (IDA) agents within five days showed near normal hepatic uptake of this hepatobiliary imaging agent. The hepatic parenchymal cells may be imaged with Tc-99m-IDA in some irradiated regions of liver, despite loss of reticuloendothelial cell function.

  16. Amyloidosis of heart and liver: comparison of Tc-99m pyrophosphate and Tc-99m methylene diphosphonate for detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, V.W.; Caldarone, A.G.; Falk, R.H.

    1983-07-01

    A prospective, comparative study was made of the efficacy of technetium-99m pyrophosphate (Tc PYP) and technetium-99m methylene diphosphonate (Tc MDP) in detecting soft-tissue amyloidois. Tc PYP and Tc MDP scans were obtained within ten-day intervals in seven patients with histologically proven amyloidosis. Tc PYP was a better scanning agent for soft-tissue amyloidosis in all patients. Cardiac and hepatic involvement were proved by autopsy in one patient. Involvement of the heart was confirmed by echocardiography in five patients. The potential use of tc PYP scannning as a screening test for soft-tissue amyloidosis is discussed.

  17. Tracer SWIW tests in propped and un-propped fractures: parameter sensitivity issues, revisited

    NASA Astrophysics Data System (ADS)

    Ghergut, Julia; Behrens, Horst; Sauter, Martin

    2017-04-01

    -scale diffusion; (iii) attempt to determine both advective and non-advective transport parameters from one and the same conservative-tracer signal (relying on 'third-party' knowledge), or from twin signals of a so-called 'dual' tracer pair, e. g.: using tracers with contrasting reactivity and partitioning behavior to determine residual saturation in depleted oilfields (Tomich et al. 1973), or to determine advective parameters (Ghergut et al. 2014); using early-time signals of conservative and sorptive tracers for propped-fracture characterization (Karmakar et al. 2015); using mid-time signals of conservative tracers for a reservoir-borne inflow profiling in multi-frac systems (Ghergut et al. 2016), etc. The poster describes new uses of type-(iii) techniques for the specific purposes of shale-gas reservoir characterization, productivity monitoring, diagnostics and engineering of 're-frac' treatments, based on parameter sensitivity findings from German BMWi research project "TRENDS" (Federal Ministry for Economic Affairs and Energy, FKZ 0325515) and from the EU-H2020 project "FracRisk" (grant no. 640979).

  18. Applicability of plasmid calibrant pTC1507 in quantification of TC1507 maize: an interlaboratory study.

    PubMed

    Meng, Yanan; Liu, Xin; Wang, Shu; Zhang, Dabing; Yang, Litao

    2012-01-11

    To enforce the labeling regulations of genetically modified organisms (GMOs), the application of DNA plasmids as calibrants is becoming essential for the practical quantification of GMOs. This study reports the construction of plasmid pTC1507 for a quantification assay of genetically modified (GM) maize TC1507 and the collaborative ring trial in international validation of its applicability as a plasmid calibrant. pTC1507 includes one event-specific sequence of TC1507 maize and one unique sequence of maize endogenous gene zSSIIb. A total of eight GMO detection laboratories worldwide were invited to join the validation process, and test results were returned from all eight participants. Statistical analysis of the returned results showed that real-time PCR assays using pTC1507 as calibrant in both GM event-specific and endogenous gene quantifications had high PCR efficiency (ranging from 0.80 to 1.15) and good linearity (ranging from 0.9921 to 0.9998). In a quantification assay of five blind samples, the bias between the test values and true values ranged from 2.6 to 24.9%. All results indicated that the developed pTC1507 plasmid is applicable for the quantitative analysis of TC1507 maize and can be used as a suitable substitute for dried powder certified reference materials (CRMs).

  19. Three-Dimensional Bayesian Geostatistical Aquifer Characterization at the Hanford 300 Area using Tracer Test Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Xingyuan; Murakami, Haruko; Hahn, Melanie S.

    2012-06-01

    Tracer testing under natural or forced gradient flow holds the potential to provide useful information for characterizing subsurface properties, through monitoring, modeling and interpretation of the tracer plume migration in an aquifer. Non-reactive tracer experiments were conducted at the Hanford 300 Area, along with constant-rate injection tests and electromagnetic borehole flowmeter (EBF) profiling. A Bayesian data assimilation technique, the method of anchored distributions (MAD) [Rubin et al., 2010], was applied to assimilate the experimental tracer test data with the other types of data and to infer the three-dimensional heterogeneous structure of the hydraulic conductivity in the saturated zone of themore » Hanford formation. In this study, the Bayesian prior information on the underlying random hydraulic conductivity field was obtained from previous field characterization efforts using the constant-rate injection tests and the EBF data. The posterior distribution of the conductivity field was obtained by further conditioning the field on the temporal moments of tracer breakthrough curves at various observation wells. MAD was implemented with the massively-parallel three-dimensional flow and transport code PFLOTRAN to cope with the highly transient flow boundary conditions at the site and to meet the computational demands of MAD. A synthetic study proved that the proposed method could effectively invert tracer test data to capture the essential spatial heterogeneity of the three-dimensional hydraulic conductivity field. Application of MAD to actual field data shows that the hydrogeological model, when conditioned on the tracer test data, can reproduce the tracer transport behavior better than the field characterized without the tracer test data. This study successfully demonstrates that MAD can sequentially assimilate multi-scale multi-type field data through a consistent Bayesian framework.« less

  20. Three-Dimensional Bayesian Geostatistical Aquifer Characterization at the Hanford 300 Area using Tracer Test Data

    NASA Astrophysics Data System (ADS)

    Chen, X.; Murakami, H.; Hahn, M. S.; Hammond, G. E.; Rockhold, M. L.; Rubin, Y.

    2010-12-01

    Tracer testing under natural or forced gradient flow provides useful information for characterizing subsurface properties, by monitoring and modeling the tracer plume migration in a heterogeneous aquifer. At the Hanford 300 Area, non-reactive tracer experiments, in addition to constant-rate injection tests and electromagnetic borehole flowmeter (EBF) profiling, were conducted to characterize the heterogeneous hydraulic conductivity field. A Bayesian data assimilation technique, method of anchored distributions (MAD), is applied to assimilate the experimental tracer test data and to infer the three-dimensional heterogeneous structure of the hydraulic conductivity in the saturated zone of the Hanford formation. In this study, the prior information of the underlying random hydraulic conductivity field was obtained from previous field characterization efforts using the constant-rate injection tests and the EBF data. The posterior distribution of the random field is obtained by further conditioning the field on the temporal moments of tracer breakthrough curves at various observation wells. The parallel three-dimensional flow and transport code PFLOTRAN is implemented to cope with the highly transient flow boundary conditions at the site and to meet the computational demand of the proposed method. The validation results show that the field conditioned on the tracer test data better reproduces the tracer transport behavior compared to the field characterized previously without the tracer test data. A synthetic study proves that the proposed method can effectively assimilate tracer test data to capture the essential spatial heterogeneity of the three-dimensional hydraulic conductivity field. These characterization results will improve conceptual models developed for the site, including reactive transport models. The study successfully demonstrates the capability of MAD to assimilate multi-scale multi-type field data within a consistent Bayesian framework. The MAD

  1. Study of axial mixing, holdup and slip velocity of dispersed phase in a pulsed sieve plate extraction column using radiotracer technique.

    PubMed

    Ghiyas Ud Din; Imran Rafiq Chughtai; Hameed Inayat, Mansoor; Hussain Khan, Iqbal

    2009-01-01

    Axial mixing, holdup and slip velocity of dispersed phase which are parameters of fundamental importance in the design and operation of liquid-liquid extraction pulsed sieve plate columns have been investigated. Experiments for residence time distribution (RTD) analysis have been carried out for a range of pulsation frequency and amplitude in a liquid-liquid extraction pulsed sieve plate column with water as dispersed and kerosene as continuous phase using radiotracer technique. The column was operated in emulsion region and (99m)Tc in the form of sodium pertechnetate eluted from a (99)Mo/(99m)Tc generator was used to trace the dispersed phase. Axial dispersed plug flow model with open-open boundary condition and two points measurement method was used to simulate the hydrodynamics of dispersed phase. It has been observed that the axial mixing and holdup of dispersed phase increases with increase in pulsation frequency and amplitude until a maximum value is achieved while slip velocity decreases with increase in pulsation frequency and amplitude until it approaches a minimum value. Short lived and low energy radiotracer (99m)Tc in the form of sodium pertechnetate was found to be a good water tracer to study the hydrodynamics of a liquid-liquid extraction pulsed sieve plate column operating with two immiscible liquids, water and kerosene. Axial dispersed plug flow model with open-open boundary condition was found to be a suitable model to describe the hydrodynamics of dispersed phase in the pulsed sieve plate extraction column.

  2. Investigations of (99m)Tc-labeled glucarate as a SPECT radiotracer for non-small cell lung cancer (NSCLC) and potential tumor uptake mechanism.

    PubMed

    Meng, Lanfang; Xiu, Yan; Li, Yanli; Xu, Xiaobo; Li, Shanqun; Li, Xiao; Pak, Koon Y; Shi, Hongcheng; Cheng, Dengfeng

    2015-07-01

    This study attempted to evaluate the feasibility of (99m)Tc-labeled glucarate ((99m)Tc-GLA) imaging in non-small cell lung cancer (NSCLC) and the potential tumor uptake mechanism. Cell lysates from two NSCLC cell lines, H292 and H1975, were immunoblotted with anti-glucose transporter 5 (GLUT5) antibody for Western blotting. Thereafter, the two cell lines were used to examine cellular uptake of (99m)Tc-GLA with or without fructose. SPECT/CT imaging studies were performed on small animals bearing H292 and H1975 tumors. Biodistribution studies were also conducted to achieve accurate tissue uptake of this tracer in two tumor models. Hematoxylin & eosin (H&E) staining and GLUT5, Ki67 and cytokeratin-7 (CK-7) immunohistochemistry (IHC) analysis were further investigated on tumor tissues. In Western blotting, H292 cells showed higher levels of GLUT5 compared to the H1975 cells. Meanwhile, the in vitro cell assays indicated GLUT5-dependent uptake of (99m)Tc-GLA in H292 and H1975 cells. The fructose competition assays showed a significant decrease in (99m)Tc-GLA uptake by H292 and H1975 cells when fructose was added. The (99m)Tc-GLA accumulation was as much as two-fold higher in H292 implanted tumors than in H1975 implanted tumors. (99m)Tc-GLA exhibited rapid clearance pharmacokinetics and reasonable uptake in human NSCLC H292 (1.69±0.37 ID%/g) and H1975 (0.89±0.06 ID%/g) implanted tumors at 30min post injection. Finally, the expression of GLUT5, Ki67 and CK-7 on tumor tissues also exhibited positive correlation with the in vitro cell test results and in vivo SPECT/CT imaging results in xenograft tumors. Both in vitro and ex vivo studies demonstrated that the uptake of (99m)Tc-GLA in NSCLC is highly related to GLUT5 expression. Imaging and further IHC results support that (99m)Tc-GLA could be a promising SPECT imaging agent for NSCLC diagnosis and prognosis evaluation. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Theoretical Modeling of (99)Tc NMR Chemical Shifts.

    PubMed

    Hall, Gabriel B; Andersen, Amity; Washton, Nancy M; Chatterjee, Sayandev; Levitskaia, Tatiana G

    2016-09-06

    Technetium-99 (Tc) displays a rich chemistry due to its wide range of accessible oxidation states (from -I to +VII) and ability to form coordination compounds. Determination of Tc speciation in complex mixtures is a major challenge, and (99)Tc nuclear magnetic resonance (NMR) spectroscopy is widely used to probe chemical environments of Tc in odd oxidation states. However, interpretation of (99)Tc NMR data is hindered by the lack of reference compounds. Density functional theory (DFT) calculations can help to fill this gap, but to date few computational studies have focused on (99)Tc NMR of compounds and complexes. This work evaluates the effectiveness of both pure generalized gradient approximation and their corresponding hybrid functionals, both with and without the inclusion of scalar relativistic effects, to model the (99)Tc NMR spectra of Tc(I) carbonyl compounds. With the exception of BLYP, which performed exceptionally well overall, hybrid functionals with inclusion of scalar relativistic effects are found to be necessary to accurately calculate (99)Tc NMR spectra. The computational method developed was used to tentatively assign an experimentally observed (99)Tc NMR peak at -1204 ppm to fac-Tc(CO)3(OH)3(2-). This study examines the effectiveness of DFT computations for interpretation of the (99)Tc NMR spectra of Tc(I) coordination compounds in high salt alkaline solutions.

  4. TracerLPM (Version 1): An Excel® workbook for interpreting groundwater age distributions from environmental tracer data

    USGS Publications Warehouse

    Jurgens, Bryant C.; Böhlke, J.K.; Eberts, Sandra M.

    2012-01-01

    TracerLPM is an interactive Excel® (2007 or later) workbook program for evaluating groundwater age distributions from environmental tracer data by using lumped parameter models (LPMs). Lumped parameter models are mathematical models of transport based on simplified aquifer geometry and flow configurations that account for effects of hydrodynamic dispersion or mixing within the aquifer, well bore, or discharge area. Five primary LPMs are included in the workbook: piston-flow model (PFM), exponential mixing model (EMM), exponential piston-flow model (EPM), partial exponential model (PEM), and dispersion model (DM). Binary mixing models (BMM) can be created by combining primary LPMs in various combinations. Travel time through the unsaturated zone can be included as an additional parameter. TracerLPM also allows users to enter age distributions determined from other methods, such as particle tracking results from numerical groundwater-flow models or from other LPMs not included in this program. Tracers of both young groundwater (anthropogenic atmospheric gases and isotopic substances indicating post-1940s recharge) and much older groundwater (carbon-14 and helium-4) can be interpreted simultaneously so that estimates of the groundwater age distribution for samples with a wide range of ages can be constrained. TracerLPM is organized to permit a comprehensive interpretive approach consisting of hydrogeologic conceptualization, visual examination of data and models, and best-fit parameter estimation. Groundwater age distributions can be evaluated by comparing measured and modeled tracer concentrations in two ways: (1) multiple tracers analyzed simultaneously can be evaluated against each other for concordance with modeled concentrations (tracer-tracer application) or (2) tracer time-series data can be evaluated for concordance with modeled trends (tracer-time application). Groundwater-age estimates can also be obtained for samples with a single tracer measurement at one

  5. 10 CFR 39.45 - Subsurface tracer studies.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Subsurface tracer studies. 39.45 Section 39.45 Energy....45 Subsurface tracer studies. (a) The licensee shall require all personnel handling radioactive tracer material to use protective gloves and, if required by the license, other protective clothing and...

  6. 10 CFR 39.45 - Subsurface tracer studies.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Subsurface tracer studies. 39.45 Section 39.45 Energy....45 Subsurface tracer studies. (a) The licensee shall require all personnel handling radioactive tracer material to use protective gloves and, if required by the license, other protective clothing and...

  7. 10 CFR 39.45 - Subsurface tracer studies.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Subsurface tracer studies. 39.45 Section 39.45 Energy....45 Subsurface tracer studies. (a) The licensee shall require all personnel handling radioactive tracer material to use protective gloves and, if required by the license, other protective clothing and...

  8. On the linearity of tracer bias around voids

    NASA Astrophysics Data System (ADS)

    Pollina, Giorgia; Hamaus, Nico; Dolag, Klaus; Weller, Jochen; Baldi, Marco; Moscardini, Lauro

    2017-07-01

    The large-scale structure of the Universe can be observed only via luminous tracers of the dark matter. However, the clustering statistics of tracers are biased and depend on various properties, such as their host-halo mass and assembly history. On very large scales, this tracer bias results in a constant offset in the clustering amplitude, known as linear bias. Towards smaller non-linear scales, this is no longer the case and tracer bias becomes a complicated function of scale and time. We focus on tracer bias centred on cosmic voids, I.e. depressions of the density field that spatially dominate the Universe. We consider three types of tracers: galaxies, galaxy clusters and active galactic nuclei, extracted from the hydrodynamical simulation Magneticum Pathfinder. In contrast to common clustering statistics that focus on auto-correlations of tracers, we find that void-tracer cross-correlations are successfully described by a linear bias relation. The tracer-density profile of voids can thus be related to their matter-density profile by a single number. We show that it coincides with the linear tracer bias extracted from the large-scale auto-correlation function and expectations from theory, if sufficiently large voids are considered. For smaller voids we observe a shift towards higher values. This has important consequences on cosmological parameter inference, as the problem of unknown tracer bias is alleviated up to a constant number. The smallest scales in existing data sets become accessible to simpler models, providing numerous modes of the density field that have been disregarded so far, but may help to further reduce statistical errors in constraining cosmology.

  9. The Phosphatidylinositol 3-kinase Class III Complex Containing TcVps15 and TcVps34 Participates in Autophagy in Trypanosoma cruzi.

    PubMed

    Schoijet, Alejandra C; Sternlieb, Tamara; Alonso, Guillermo D

    2017-05-01

    Autophagy is a degradative process by which eukaryotic cells digest their own components to provide aminoacids that may function as energy source under nutritional stress conditions. There is experimental evidence for autophagy in parasitic protists belonging to the family Trypanosomatidae. However, few proteins implicated in this process have been characterized so far in these parasites. Moreover, it has been shown that autophagy is involved in Trypanosoma cruzi differentiation and thus might have a role in pathogenicity. Here, we report the cloning and biochemical characterization of TcVps15. In addition, we demonstrate that TcVps15 interact with the PI3K TcVps34 and that both proteins associate with cellular membranes. Under nutritional stress conditions, TcVps15 and TcVps34 modify their subcellular distribution showing a partial co-localization in autophagosomes with TcAtg8.1 and using an active site TcVps15-mutated version (TcVps15-K219D-HA) we demonstrated that this relocalization depends on the TcVps15 catalytic activity. Overexpression of TcVps15-HA and TcVps15-K219D-HA also leads to increased accumulation of monodansylcadaverine (MDC) in autophagic vacuoles under nutritional stress conditions compared to wild-type cells. In addition, the MDC-specific activity shows to be significantly higher in TcVps15-HA overexpressing cells when compared with TcVps15-K219D-HA. Our results reveal for the first time a role of TcVps15 as a key regulator of TcVps34 enzymatic activity and implicate the TcVps15-Vps34 complex in autophagy in T. cruzi, exposing a new key pathway to explore novel chemotherapeutic targets. © 2016 The Author(s) Journal of Eukaryotic Microbiology © 2016 International Society of Protistologists.

  10. Non-input analysis for incomplete trapping irreversible tracer with PET.

    PubMed

    Ohya, Tomoyuki; Kikuchi, Tatsuya; Fukumura, Toshimitsu; Zhang, Ming-Rong; Irie, Toshiaki

    2013-07-01

    When using metabolic trapping type tracers, the tracers are not always trapped in the target tissue; i.e., some are completely trapped in the target, but others can be eliminated from the target tissue at a measurable rate. The tracers that can be eliminated are termed 'incomplete trapping irreversible tracers'. These incomplete trapping irreversible tracers may be clinically useful when the tracer β-value, the ratio of the tracer (metabolite) elimination rate to the tracer efflux rate, is under approximately 0.1. In this study, we propose a non-input analysis for incomplete trapping irreversible tracers based on the shape analysis (Shape), a non-input analysis used for irreversible tracers. A Monte Carlo simulation study based on experimental monkey data with two actual PET tracers (a complete trapping irreversible tracer [(11)C]MP4A and an incomplete trapping irreversible tracer [(18)F]FEP-4MA) was performed to examine the effects of the environmental error and the tracer elimination rate on the estimation of the k3-parameter (corresponds to metabolic rate) using Shape (original) and modified Shape (M-Shape) analysis. The simulation results were also compared with the experimental results obtained with the two PET tracers. When the tracer β-value was over 0.03, the M-Shape method was superior to the Shape method for the estimation of the k3-parameter. The simulation results were also in reasonable agreement with the experimental ones. M-Shape can be used as the non-input analysis of incomplete trapping irreversible tracers for PET study. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. Simultaneous 3D tracking of passive tracers and microtubule bundles in an active gel

    NASA Astrophysics Data System (ADS)

    Fan, Yi; Breuer, Kenneth S.; Fluids Team

    Kinesin-driven microtubule bundles generate a spontaneous flow in unconfined geometries. They exhibit properties of active matter, including the emergence of collective motion, reduction of apparent viscosity and consumption of local energy. Here we present results from 3D tracking of passive tracers (using Airy rings and 3D scanning) synchronized with 3D measurement of the microtubule bundles motion. This technique is applied to measure viscosity variation and collective flow in a confined geometry with particular attention paid to the self-pumping system recently reported by Wu et al. (2016). Results show that the viscosity in an equilibrium microtubule network is around half that of the isotropic unbundled microtubule solution. Cross-correlations of the active microtubule network and passive tracers define a neighborhood around microtubule bundles in which passive tracers are effectively transported. MRSEC NSF.

  12. Quantifying Surface Water, Porewater, and Groundwater Interactions Using Tracers: Tracer Fluxes, Water Fluxes, and End-member Concentrations

    NASA Astrophysics Data System (ADS)

    Cook, Peter G.; Rodellas, Valentí; Stieglitz, Thomas C.

    2018-03-01

    Tracer approaches to estimate both porewater exchange (the cycling of water between surface water and sediments, with zero net water flux) and groundwater inflow (the net flow of terrestrially derived groundwater into surface water) are commonly based on solute mass balances. However, this requires appropriate characterization of tracer end-member concentrations in exchanging or discharging water. Where either porewater exchange or groundwater inflow to surface water occur in isolation, then the water flux is easily estimated from the net tracer flux if the end-member is appropriately chosen. However, in most natural systems porewater exchange and groundwater inflow will occur concurrently. Our analysis shows that if groundwater inflow (Qg) and porewater exchange (Qp) mix completely before discharging to surface water, then the combined water flux (Qg + Qp) can be approximated by dividing the combined tracer flux by the difference between the porewater and surface water concentrations, (cp - c). If Qg and Qp do not mix prior to discharge, then (Qg + Qp) can only be constrained by minimum and maximum values. The minimum value is obtained by dividing the net tracer flux by the groundwater concentration, and the maximum is obtained by dividing by (cp - c). Dividing by the groundwater concentration gives a maximum value for Qg. If porewater exchange and groundwater outflow occur concurrently, then dividing the net tracer flux by (cp - c) will provide a minimum value for Qp. Use of multiple tracers, and spatial and temporal replication should provide a more complete picture of exchange processes and the extent of subsurface mixing.

  13. Tracer airflow measurement system (TRAMS)

    DOEpatents

    Wang, Duo [Albany, CA

    2007-04-24

    A method and apparatus for measuring fluid flow in a duct is disclosed. The invention uses a novel high velocity tracer injector system, an optional insertable folding mixing fan for homogenizing the tracer within the duct bulk fluid flow, and a perforated hose sampling system. A preferred embodiment uses CO.sub.2 as a tracer gas for measuring air flow in commercial and/or residential ducts. In extant commercial buildings, ducts not readily accessible by hanging ceilings may be drilled with readily plugged small diameter holes to allow for injection, optional mixing where desired using a novel insertable foldable mixing fan, and sampling hose.

  14. Transient tracer applications in the Southern Ocean

    NASA Astrophysics Data System (ADS)

    Stöven, T.; Tanhua, T.; Hoppema, M.

    2014-10-01

    Transient tracers can be used to constrain the Inverse-Gaussian transit time distribution (IG-TTD) and thus provide information about ocean ventilation. Individual transient tracers have different time and application ranges which are defined by their atmospheric history (chronological transient tracers) or their decay rate (radioactive transient tracers). The classification ranges from tracers for highly ventilated water masses, e.g. sulfur hexafluoride (SF6), the decay of Tritium (δ3H) and to some extent also dichlorodifluoromethane (CFC-12) to tracers for less ventilated deep ocean basins, e.g. CFC-12, Argon-39 (39Ar) and radiocarbon (14C). The IG-TTD can be empirically constrained by using transient tracer couples with sufficiently different input functions. Each tracer couple has specific characteristics which influence the application limit of the IG-TTD. Here we provide an overview of commonly used transient tracer couples and their validity areas within the IG-TTD by using the concept of tracer age differences (TAD). New measured CFC-12 and SF6 data from a section along 10° E in the Southern Ocean in 2012 are presented. These are combined with a similar data set of 1998 along 6° E in the Southern Ocean as well as with 39Ar data from the early 1980s in the western Atlantic Ocean and the Weddell Sea for investigating the application limit of the IG-TTD and to analyze changes in ventilation in the Southern Ocean. We found that the IG-TTD can be constrained south to 46° S which corresponds to the Subantarctic Front (SAF) denoting the application limit. The constrained IG-TTD north of the SAF shows a slight increase in mean ages between 1998 and 2012 in the upper 1200 m between 42-46° S. The absence of SF6 inhibits ventilation analyses below this depth. The time lag analysis between the 1998 and 2012 data shows an increase in ventilation down to 1000 m and a steady ventilation between 2000 m-bottom south of the SAF between 51-55° S.

  15. 99mTc-EDDA/HYNIC-octreotate in detection of atypical bronchial carcinoid.

    PubMed

    Hubalewska-Dydejczyk, A; Fröss-Baron, K; Gołkowski, F; Sowa-Staszczak, A; Mikołajczak, R; Huszno, B

    2007-01-01

    Pulmonary carcinoids cause serious difficulties in imaging diagnostics in all stages of the disease. SRS holds great promise for detecting occult primary tu and metastatic lesions. (99m)Tc-EDDA/HYNIC-octreotate, a new scintigraphic agent, should significantly improve sensitivity of the diagnostics of carcinoids due to better affinity to SSR2 than (111)In-Octreoscan and the higher count rate obtained from (99m)Tc over (111)In. We present a case of a 40-year-old women operated on because of lung carcinoid tumour in 2002. The symptoms did not resolve after the operation and 5-OHIAA was still elevated. The thorax spiral CT revealed the focal lesion beneath carina. (111)In-Octreoscan and (99m)Tc-EDDA/HYNIC-octreotate SRS revealed two focal lesions in the mediastinum. (99m)Tc-EDDA/HYNIC-octreotate detected two additional lesions in the lower part of the right lung. Target/non-target count ratios of the lesions were as follows: (99m)Tc-EDDA/HYNIC-octreotate scans - 2,9, (111)In-Octreoscan- 2,1. PET-FDG examination revealed no pathology. Owing to severe bone pains and carcinoid symptoms the patient was referred for the 90Y-DOTA-octreotate treatment. SRS with a new 99mTc marked somatostatin analogue - octreotate allows for a more sensitive detection of metastatic leasions in carcinoid tumours. The usefulness of 18F-FDG PET, widely used as a powerful imaging technique in clinical oncology, is limited in detection of carcinoid tumours due to the low proliferative activity.

  16. Pattern of myocardial 99mTc-HMDP uptake and impact on myocardial function in patients with transthyretin cardiac amyloidosis.

    PubMed

    Pradel, Sarah; Brun, Stéphanie; Victor, Gérard; Pascal, Pierre; Fournier, Pauline; Ribes, David; Lavie-Badie, Yoan; Galinier, Michel; Carrié, Didier; Berry, Isabelle; Lairez, Olivier

    2018-06-07

    The purpose of the study was to describe the pattern of 99m Tc-labeled phosphate agents myocardial uptake by scintigraphy and explore its impact on left ventricular (LV) functions in transthyretin cardiac amyloidosis (TTR-CA). Fifty patients with TTR-CA underwent 99m Tc- hydroxymethylene-diphosphonate ( 99m Tc-HMDP) scintigraphy and echocardiography with measure of LV thickness, longitudinal strain (LS), systolic and diastolic functions. Cardiac retention by scintigraphy was assessed by visual scoring and the heart/whole body (H/WB) ratio was calculated by dividing counts in the heart by counts in late whole-body images. The mean population age was 79 ± 10 years. Mean H/WB ratio was 12 ± 7. Myocardial 99m Tc-HMDP uptake on segments 5, 6, 7, 8, 11, 12, 13, 14, 16, and 17 was correlated with H/WB ratio. Mean LVEF and global LS were 51 ± 10% and - 10 ± 3%, respectively. H/WB ratio was correlated with global LS (R = 0.408, P = .003), Ea (R = - 0.566, P < .001) and mean left ventricular wall thickness (R = 0.476, P < .001) but not with LVEF (R = - 0.109, P = .453). Segmental myocardial uptake was slightly correlated with segmental LS (R = 0.152, P < .001). H/WB ratio was not correlated with NT-proBNP levels (R = 0.219, P = .148) neither E/Ea ratio (R = 0.204, P = .184). These findings show the relationship between bone tracer myocardial uptake and LV functions in patients with TTR cardiac amyloidosis.

  17. Using high resolution measurements of gas tracers to determine metabolic rates in streams

    NASA Astrophysics Data System (ADS)

    Knapp, J. L.; Osenbrück, K.; Brennwald, M. S.; Cirpka, O. A.

    2017-12-01

    Hyporheic exchange and other hyporheic processes are strongly linked to stream respiration, as the majority of a streams' microorganisms are located within the streambed. Directly estimating these respiration rates on the reach scale is usually not possible, but they can indirectly be inferred from measurements of dissolved oxygen. This, however, requires determining stream reaeration rates with high precision. Conducting gas-tracer tests has been found to be the most reliable method to estimate stream reaeration, but the majority of field-based sampling techniques for tracer gases are either costly in time and materials, or imprecise. By contrast, on-site gas analysis using gas-equilibrium membrane-inlet mass spectrometers (miniRUEDI, Gasometrix GmbH [1]) avoid the errors caused by sampling, storage, and analysis in the standard sampling techniques. Furthermore, the high analytical frequency of the on-site mass-spectrometer provides concentration data exhibiting a low uncertainty. We present results from gas-tracer tests with a continuous injection of propane and noble gases as tracers in a number of small streams. The concentrations of the tracer gases are recorded continuously over time at the first measurement station to account for fluctuations of the input signal, whereas shorter sample sets are collected at all further measurement stations. Reaeration rate constants are calculated from gas measurements for individual stream sections. These rates are then used to estimate metabolic rates of respiration and primary production based on time series of oxygen measurements. To demonstrate the advancement of the method provided by the on-site analysis, results from measurements performed by on-site mass spectroscopy are compared to those from traditional headspace sampling with gas chromatography analysis. Additionally, differences in magnitude and uncertainty of the obtained reaeration rates of oxygen and calculated metabolic rates from both methods highlight the

  18. High Tc bolometer developments for planetary missions

    NASA Technical Reports Server (NTRS)

    Brasunas, J.; Lakew, B.

    1991-01-01

    A simple polishing technique was developed for thinning the LaAlO3 substrates for high-quality Tc bolometer films, and thus reducing their heat capacity. A 150-ms bolometer was made on a LaAlO3 substrate with a 5-Hz D* value of 1.5 x 10 exp 8. It is shown that passive temperature stabilization is adequate for operation at the transition. There remained excess noise at the transition, but this noise appears to be of nonbolometric origin.

  19. Hybrid dynamic radioactive particle tracking (RPT) calibration technique for multiphase flow systems

    NASA Astrophysics Data System (ADS)

    Khane, Vaibhav; Al-Dahhan, Muthanna H.

    2017-04-01

    The radioactive particle tracking (RPT) technique has been utilized to measure three-dimensional hydrodynamic parameters for multiphase flow systems. An analytical solution to the inverse problem of the RPT technique, i.e. finding the instantaneous tracer positions based upon instantaneous counts received in the detectors, is not possible. Therefore, a calibration to obtain a counts-distance map is needed. There are major shortcomings in the conventional RPT calibration method due to which it has limited applicability in practical applications. In this work, the design and development of a novel dynamic RPT calibration technique are carried out to overcome the shortcomings of the conventional RPT calibration method. The dynamic RPT calibration technique has been implemented around a test reactor with 1foot in diameter and 1 foot in height using Cobalt-60 as an isotopes tracer particle. Two sets of experiments have been carried out to test the capability of novel dynamic RPT calibration. In the first set of experiments, a manual calibration apparatus has been used to hold a tracer particle at known static locations. In the second set of experiments, the tracer particle was moved vertically downwards along a straight line path in a controlled manner. The obtained reconstruction results about the tracer particle position were compared with the actual known position and the reconstruction errors were estimated. The obtained results revealed that the dynamic RPT calibration technique is capable of identifying tracer particle positions with a reconstruction error between 1 to 5.9 mm for the conditions studied which could be improved depending on various factors outlined here.

  20. 99mTc-EDDA/HYNIC-Tyr(3)-octreotide for staging and follow-up of patients with neuroendocrine gastro-entero-pancreatic tumors.

    PubMed

    Gabriel, M; Muehllechner, P; Decristoforo, C; von Guggenberg, E; Kendler, D; Prommegger, R; Profanter, C; Moncayo, R; Virgolini, I

    2005-09-01

    To evaluate the use of 99mTc-EDDA-hydrazinonicotinyl-Tyr3-octreotide (Tc-TOC) for staging and follow-up of neuroendocrine gastro-entero-pancreatic (GEP) tumors with special focus on the acquisition protocol including single photon emission computed tomography (SPECT). Eighty-eight patients (37 female, 51 male; age range: 16 to 81 years; mean age: 56.3 years) were studied: 42 patients for staging after initial histological confirmation and 46 patients during post-therapy follow-up. An average activity of 400 MBq of the radiopharmaceutical was injected. All tumors originated from neuroendocrine tissue of the gastroenteropancreatic tract. Whole body scintigrams at 4 h postinjection and SPECT of the abdomen were obtained in all patients. Additional planar images of the abdomen were acquired at 2 h after injection in 68 patients. The Tc-TOC scan result was true-positive in 56 patients, true-negative in 17, false-negative in 14, and false-positive in 1 patient. The false-positive finding was caused by a colonic adenoma. Overall, a scan sensitivity of 80% (56/70 patients), specificity of 94.4% (17/18 patients) and accuracy of 82.9% (73/88 patients) were calculated on patient basis. In total, Tc-TOC detected 357 foci in 69 patients. In 7 patients equivocal findings were observed in the bowel at 4 h postinjection without corresponding tracer uptake in the scan 2 h earlier, meaning that these abnormal findings were correctly classified as non-malignant. In addition to planar views, SPECT revealed further 62 lesions. Tc-TOC with one-day, dual-time acquisition protocol is an accurate staging procedure in patients with neuroendocrine GEP tumors. SPECT shows high sensitivity for detection of abdominal lesions, while earlier images improve the reliability of abnormal abdominal findings.

  1. In Vitro-Generated Tc17 Cells Present a Memory Phenotype and Serve As a Reservoir of Tc1 Cells In Vivo

    PubMed Central

    Flores-Santibáñez, Felipe; Cuadra, Bárbara; Fernández, Dominique; Rosemblatt, Mariana V.; Núñez, Sarah; Cruz, Pablo; Gálvez-Cancino, Felipe; Cárdenas, J. César; Lladser, Alvaro; Rosemblatt, Mario; Bono, María Rosa; Sauma, Daniela

    2018-01-01

    Memory CD8+ T cells are ideal candidates for cancer immunotherapy because they can mediate long-term protection against tumors. However, the therapeutic potential of different in vitro-generated CD8+ T cell effector subsets to persist and become memory cells has not been fully characterized. Type 1 CD8+ T (Tc1) cells produce interferon-γ and are endowed with high cytotoxic capacity, whereas IL-17-producing CD8+ T (Tc17) cells are less cytotoxic but display enhanced self-renewal capacity. We sought to evaluate the functional properties of in vitro-generated Tc17 cells and elucidate their potential to become long lasting memory cells. Our results show that in vitro-generated Tc17 cells display a greater in vivo persistence and expansion in response to secondary antigen stimulation compared to Tc1 cells. When transferred into recipient mice, Tc17 cells persist in secondary lymphoid organs, present a recirculation behavior consistent with central memory T cells, and can shift to a Tc1 phenotype. Accordingly, Tc17 cells are endowed with a higher mitochondrial spare respiratory capacity than Tc1 cells and express higher levels of memory-related molecules than Tc1 cells. Together, these results demonstrate that in vitro-generated Tc17 cells acquire a central memory program and provide a lasting reservoir of Tc1 cells in vivo, thus supporting the use of Tc17 lymphocytes in the design of novel and more effective therapies. PMID:29472932

  2. Three-dimensional Bayesian geostatistical aquifer characterization at the Hanford 300 Area using tracer test data

    NASA Astrophysics Data System (ADS)

    Chen, Xingyuan; Murakami, Haruko; Hahn, Melanie S.; Hammond, Glenn E.; Rockhold, Mark L.; Zachara, John M.; Rubin, Yoram

    2012-06-01

    Tracer tests performed under natural or forced gradient flow conditions can provide useful information for characterizing subsurface properties, through monitoring, modeling, and interpretation of the tracer plume migration in an aquifer. Nonreactive tracer experiments were conducted at the Hanford 300 Area, along with constant-rate injection tests and electromagnetic borehole flowmeter tests. A Bayesian data assimilation technique, the method of anchored distributions (MAD) (Rubin et al., 2010), was applied to assimilate the experimental tracer test data with the other types of data and to infer the three-dimensional heterogeneous structure of the hydraulic conductivity in the saturated zone of the Hanford formation.In this study, the Bayesian prior information on the underlying random hydraulic conductivity field was obtained from previous field characterization efforts using constant-rate injection and borehole flowmeter test data. The posterior distribution of the conductivity field was obtained by further conditioning the field on the temporal moments of tracer breakthrough curves at various observation wells. MAD was implemented with the massively parallel three-dimensional flow and transport code PFLOTRAN to cope with the highly transient flow boundary conditions at the site and to meet the computational demands of MAD. A synthetic study proved that the proposed method could effectively invert tracer test data to capture the essential spatial heterogeneity of the three-dimensional hydraulic conductivity field. Application of MAD to actual field tracer data at the Hanford 300 Area demonstrates that inverting for spatial heterogeneity of hydraulic conductivity under transient flow conditions is challenging and more work is needed.

  3. High Resolution Pre-Clinical CT and SPECT Imaging Techniques for Investigating Flow and Transport Mechanisms in Porous Media

    NASA Astrophysics Data System (ADS)

    Dogan, M.; Moysey, S. M.; Mamun, A. A.; DeVol, T. A.; Powell, B. A.; Murdoch, L. C.

    2017-12-01

    Single Photon Emission Computed Tomography (SPECT) and x-ray Computed Tomography (CT) are both high-resolution imaging methods for investigating laboratory scale samples. We have recently conducted several experiments to determine the capabilities of two preclinical imaging systems; the imaging resolution of the two systems studied were found to be 0.2 mm for CT and 2-4 mm for SPECT depending on the tracer and scan times. While the resolution of these instruments is not sufficient for imaging the pore structure of most soils, it is sufficient to resolve macropore structures such as cracks and root channels and to observe their impact on transport. For example, we have used CT scans to monitor the formation of desiccation cracks within soils obtained from the Savannah River Site. We were then able to observe the interaction between the crack network and pore matrix during an infiltration experiment by spiking the infiltrating water with an iodide contrast agent as a tracer. We found a complex interaction between the flow systems, where flow shifted from matrix dominated at low flow rates to macropore dominated at high flow rates. SPECT imaging is capable of monitoring the distribution of gamma-ray emitting radionuclides in 3D. It is therefore also a useful tool for monitoring transport processes, but is particularly powerful when a redox sensitive isotope like 99mTc is used as the tracer. We show an example of a transport experiment where a 99mTc solution is passed through a column containing zones with different redox properties, i.e., a zone amended with titanomagnetite, another with anatase, and a third with silica flour. The 99mTc is captured by the strongly reducing materials, but not the zone with silica flour. The example illustrates how these imaging modalities can be used to discriminate between chemical and physical processes controlling fate and transport of the radionuclide. In particular, CT and SPECT can be used to image contaminant transport in lab

  4. Vertical distributions of (99)Tc and the (99)Tc/(137)Cs activity ratio in the coastal water off Aomori, Japan.

    PubMed

    Nakanishi, Takahiro; Zheng, Jian; Aono, Tatsuo; Yamada, Masatoshi; Kusakabe, Masashi

    2011-08-01

    Using a sector-field ICP-MS the vertical distributions of the (99)Tc concentration and (99)Tc/(137)Cs activity ratio were measured in the coastal waters off Aomori Prefecture, Japan, where a spent-nuclear-fuel reprocessing plant has begun test operation. The (99)Tc concentrations in surface water ranged from 1.8 to 2.4 mBq/m(3), no greater than the estimated background level. Relatively high (99)Tc/(137)Cs activity ratios (10-12 × 10(-4)) would be caused by the inflow of the high-(99)Tc/(137)Cs water mass from the Japan Sea. There is no observable contamination from the reprocessing plant in the investigated area. The (99)Tc concentration and the (99)Tc/(137)Cs activity ratio in water column showed gradual decreases with depth. Our results implied that (99)Tc behaves in a more conservative manner than (137)Cs in marine environments. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Diuretic renography in hydronephrosis: renal tissue tracer transit predicts functional course and thereby need for surgery.

    PubMed

    Schlotmann, Andreas; Clorius, John H; Clorius, Sandra N

    2009-10-01

    The recognition of those hydronephrotic kidneys which require therapy to preserve renal function remains difficult. We retrospectively compared the 'tissue tracer transit' (TTT) of (99m)Tc-mercaptoacetyltriglycine ((99m)Tc-MAG(3)) with 'response to furosemide stimulation' (RFS) and with 'single kidney function < 40%' (SKF < 40%) to predict functional course and thereby need for surgery. Fifty patients with suspected unilateral obstruction and normal contralateral kidney had 115 paired (baseline/follow-up) (99m)Tc-MAG(3) scintirenographies. Three predictions of the functional development were derived from each baseline examination: the first based on TTT (visually assessed), the second on RFS and the third on SKF < 40%. Each prediction also considered whether the patient had surgery. Possible predictions were 'better', 'worse' or 'stable' function. A comparison of SKF at baseline and follow-up verified the predictions. The frequency of correct predictions for functional improvement following surgery was 8 of 10 kidneys with delayed TTT, 9 of 22 kidneys with obstructive RFS and 9 of 21 kidneys with SKF < 40%; for functional deterioration without surgery it was 2 of 3 kidneys with delayed TTT, 3 of 20 kidneys with obstructive RFS and 3 of 23 kidneys with SKF < 40%. Without surgery 67 of 70 kidneys with timely TTT maintained function. Without surgery 0 of 9 kidneys with timely TTT but obstructive RFS and only 1 of 16 kidneys with timely TTT but SKF < 40% lost function. Delayed TTT appears to identify the need for therapy to preserve function of hydronephrotic kidneys, while timely TTT may exclude risk even in the presence of an obstructive RFS or SKF < 40%.

  6. Differential Activation of CD8+ Tumor-Specific Tc1 and Tc2 Cells by an IL-10-Producing Murine Plasmacytoma

    PubMed Central

    Pauels, Hans-Gerd; Becker, Christian; Kölsch, Eckehart

    1998-01-01

    The involvement of counteractive CD8+ T-cell subsets during tumor-specific immune responses was analyzed in a syngeneic murine plasmacytoma model. CD8+ Tc cells against the immunogenic IL-10-producing BALB/c plasmacytoma ADJ-PC-5 can be easily induced by immunization of BALB/c mice with X-irradiated ADJ-PC-5 tumor cells in vivo and in vitro. However, the failure of recipient mice to mount a protective Tc response against the tumor during early stages of a real or simulated tumor growth is not due to immunological ignorance, but depends on the induction of tumor-specific tolerance, involving a population of tumorinduced CD8+ T cells that are able to inhibit the generation of tumor-specific Tc cells in a primary ADJ-PC-5-specific MLTC, using IFN-γ as a suppressive factor. Whereas most longterm cultivated CD8+ ADJ-PC-5-specific Tc lines produce type-1 cytokines on stimulation, at least two of them, which were derived from a primary MLTC, display a type-2 cytokine spectrum. Furthermore, the primary in vitro Tc response against ADJ-PC-5 cells shows characteristics of a Tc2 response. The Tc response is strictly depending on tumor-derived IL-10. CD8+ Tc cells that are induced in a primary MLTC do not produce IFN-γ, and the tumor-specific Tc response is enhanced by IL-4 but suppressed by IFN-γ or IL-12. In contrast, ADJ-PC- 5-specific CD8+ Tc cells from immunized mice are IFN-γ producing Tc1 cells. Since the primary in vitro Tc response against the tumor is suppressed even by the smallest numbers of irradiated ADJ-PC-5-specific Tc1 cells via IFN-γ these Tc1 cells behave similar to the suppressive CD8+ T cells that are induced during early stages of ADJ-PC-5 tumorigenesis. PMID:9814607

  7. Determination of technetium-99 in environmental samples: a review.

    PubMed

    Shi, Keliang; Hou, Xiaolin; Roos, Per; Wu, Wangsuo

    2012-01-04

    Due to the lack of a stable technetium isotope, and the high mobility and long half-life, (99)Tc is considered to be one of the most important radionuclides in safety assessment of environmental radioactivity as well as nuclear waste management. (99)Tc is also an important tracer for oceanographic research due to the high technetium solubility in seawater as TcO(4)(-). A number of analytical methods, using chemical separation combined with radiometric and mass spectrometric measurement techniques, have been developed over the past decades for determination of (99)Tc in different environmental samples. This article summarizes and compares recently reported chemical separation procedures and measurement methods for determination of (99)Tc. Due to the extremely low concentration of (99)Tc in environmental samples, the sample preparation, pre-concentration, chemical separation and purification for removal of the interferences for detection of (99)Tc are the most important issues governing the accurate determination of (99)Tc. These aspects are discussed in detail in this article. Meanwhile, the different measurement techniques for (99)Tc are also compared with respect to advantages and drawbacks. Novel automated analytical methods for rapid determination of (99)Tc using solid extraction or ion exchange chromatography for separation of (99)Tc, employing flow injection or sequential injection approaches are also discussed. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. LARGE-SCALE NATURAL GRADIENT TRACER TEST IN SAND AND GRAVEL, CAPE COD, MASSACHUSETTS - 1. EXPERIMENTAL DESIGN AND OBSERVED TRACER MOVEMENT

    EPA Science Inventory

    A large-scale natural gradient tracer experiment was conducted on Cape Cod, Massachusetts, to examine the transport and dispersion of solutes in a sand and gravel aquifer. The nonreactive tracer, bromide, and the reactive tracers, lithium and molybdate, were injected as a pulse i...

  9. Application of Tracer-Injection Techniques to Demonstrate Surface-Water and Ground-Water Interactions Between an Alpine Stream and the North Star Mine, Upper Animas River Watershed, Southwestern Colorado

    USGS Publications Warehouse

    Wright, Winfield G.; Moore, Bryan

    2003-01-01

    Tracer-injection studies were done in Belcher Gulch in the upper Animas River watershed, southwestern Colorado, to determine whether the alpine stream infiltrates into underground mine workings of the North Star Mine and other nearby mines in the area. The tracer-injection studies were designed to determine if and where along Belcher Gulch the stream infiltrates into the mine. Four separate tracer-injec-tion tests were done using lithium bromide (LiBr), optical brightener dye, and sodium chloride (NaCl) as tracer solu-tions. Two of the tracers (LiBr and dye) were injected con-tinuously for 24 hours, one of the NaCl tracers was injected continuously for 12 hours, and one of the NaCl tracers was injected over a period of 1 hour. Concentration increases of tracer constituents were detected in water discharging from the North Star Mine, substantiating a surface-water and ground-water connection between Belcher Gulch and the North Star Mine. Different timing and magnitude of tracer breakthroughs indicated multiple flow paths with different residence times from the stream to the mine. The Pittsburgh and Sultan Mines were thought to physically connect to the North Star Mine, but tracer breakthroughs were inconclusive in water from these mines. From the tracer-injection tests and synoptic measure-ments of streamflow discharge, a conceptual model was devel-oped for surface-water and ground-water interactions between Belcher Gulch and the North Star Mine. This information, combined with previous surface geophysical surveys indicat-ing the presence of subsurface voids, may assist with decision-making process for preventing infiltration and for the remedia-tion of mine drainage from these mines.

  10. Quantitative in vivo receptor binding. III. Tracer kinetic modeling of muscarinic cholinergic receptor binding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frey, K.A.; Hichwa, R.D.; Ehrenkaufer, R.L.

    1985-10-01

    A tracer kinetic method is developed for the in vivo estimation of high-affinity radioligand binding to central nervous system receptors. Ligand is considered to exist in three brain pools corresponding to free, nonspecifically bound, and specifically bound tracer. These environments, in addition to that of intravascular tracer, are interrelated by a compartmental model of in vivo ligand distribution. A mathematical description of the model is derived, which allows determination of regional blood-brain barrier permeability, nonspecific binding, the rate of receptor-ligand association, and the rate of dissociation of bound ligand, from the time courses of arterial blood and tissue tracer concentrations.more » The term ''free receptor density'' is introduced to describe the receptor population measured by this method. The technique is applied to the in vivo determination of regional muscarinic acetylcholine receptors in the rat, with the use of (TH)scopolamine. Kinetic estimates of free muscarinic receptor density are in general agreement with binding capacities obtained from previous in vivo and in vitro equilibrium binding studies. In the striatum, however, kinetic estimates of free receptor density are less than those in the neocortex--a reversal of the rank ordering of these regions derived from equilibrium determinations. A simplified model is presented that is applicable to tracers that do not readily dissociate from specific binding sites during the experimental period.« less

  11. Across North America tracer experiment (ANATEX): Sampling and analysis

    NASA Astrophysics Data System (ADS)

    Draxler, R. R.; Dietz, R.; Lagomarsino, R. J.; Start, G.

    Between 5 January 1987 and 29 March 1987, there were 33 releases of different tracers from each of two sites: Glasgow, MT and St. Cloud, MN. The perfluorocarbon tracers were routinely released in a 3-h period every 2.5 days, alternating between daytime and night-time tracer releases. Ground-level air samples of 24-h duration were taken at 77 sites mostly located near rawinsonde stations east of 105°W and between 26°N and 55°N. Weekly air samples were taken at 12 remote sites between San Diego, CA and Pt. Barrow, AK and between Norway and the Canary Islands. Short-term 6-h samples were collected at ground level and 200 m AGL along an arc of five towers between Tulsa, OK and Green Bay, WI. Aircraft sampling within several hundred kilometers of both tracer release sites was used to establish the initial tracer path. Experimental design required improved sampler performance, new tracers with lower atmospheric backgrounds, and improvements in analytic precision. The advances to the perfluorocarbon tracer system are discussed in detail. Results from the tracer sampling showed that the average and peak concentrations measured over the daily ground-level sampling network were consistent with what would be calculated using mass conservative approaches. however, ground-level samples from individual tracer patterns showed considerable complexity due to vertical stability or the interaction of the tracer plumes with low pressure and frontal systems. These systems could pass right through the tracer plume without appreciable effect. Aircraft tracer measurements are used to confirm the initial tracer trajectory when the narrow plume may miss the coarser spaced ground-level sampling network. Tower tracer measurements showed a more complex temporal structure than evident from the longer duration ground-level sampling sites. Few above background plume measurements were evident in the more distant remote sampling network due to larger than expected uncertainties in the ambient

  12. Multifractal detrended fluctuation analysis of intensity time series of photons scattered by tracer particles within a polymeric gel

    NASA Astrophysics Data System (ADS)

    Telesca, Luciano; Haro-Pérez, Catalina; Moreno-Torres, L. Rebeca; Ramirez-Rojas, Alejandro

    2018-01-01

    Some properties of spatial confinement of tracer colloidal particles within polyacrylamide dispersions are studied by means of the well-known dynamic light scattering (DLS) technique. DLS allows obtaining sequences of elapsed times of scattered photons. In this work, the aqueous polyacrylamide dispersion has no crosslinking and the volume fraction occupied by the tracer particles is 0.02 %. Our experimental setup provides two sequences of photons scattered by the same scattering volume that corresponds to two simultaneous experiments (Channel A and Channel B). By integration of these sequences, the intensity time series are obtained. We find that both channels are antipersistent with Hurst exponent, H ∼0.43 and 0.36, respectively. The antipersistence of the intensity time series indicates a subdiffusive dynamics of the tracers in the polymeric network, which is in agreement with the time dependence of the tracer's mean square displacement.

  13. Radon as a Tracer for Lunar Volatiles

    NASA Technical Reports Server (NTRS)

    Friesen, Larry Jay

    1992-01-01

    Radon and its decay product polonium can be used as tracers to search for lunar volatiles. One effective technique to look for them would be by using alpha-particle spectrometers from lunar orbit. Alpha spectrometers were flown in the Apollo Service Modules during the Apollo 15 and 16 missions, and did observe Rn-222 and its decay product Po-210 on the lunar surface from orbit. This demonstrates that radon and polonium can be observed from orbit; what must next be shown is that such observations can reveal something about the locations of volatiles on the Moon.

  14. Nuclear Cardiology: Are We Using the Right Protocols and Tracers the Right Way?

    PubMed

    Dondi, Maurizio; Pascual, Thomas; Paez, Diana; Einstein, Andrew J

    2017-12-01

    The field of nuclear cardiology has changed considerably over recent years, with greater attention paid to safety and radiation protection issues. The wider usage of technetium-99m (Tc-99m)-labeled radiopharmaceuticals for single-photon emission computed tomography (SPECT) imaging using gamma cameras has contributed to better quality studies and lower radiation exposure to patients. Increased availability of tracers and scanners for positron emission tomography (PET) will help further improve the quality of studies and quantify myocardial blood flow and myocardial flow reserve, thus enhancing the contribution of non-invasive imaging to the management of coronary artery disease. The introduction of new instrumentation such as solid state cameras and new software will help reduce further radiation exposure to patients undergoing nuclear cardiology studies. Results from recent studies, focused on assessing the relationship between best practices and radiation risk, provide useful insights on simple measures to improve the safety of nuclear cardiology studies without compromising the quality of results.

  15. Bone scan findings in hypervitaminosis D: case report. [/sup 99m/Tc tracer technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fogelman, I.; McKillop, J.H.; Cowden, E.A.

    1977-12-01

    Bone scans in three patients showed generalized symmetrical increased uptake of radiopharmaceutical by the skeleton and absent or faint kidney images. It is thought that these appearances may be attributable to excess vitamin D, and other possible contributing factors, including the presence of renal osteodystrophy, are discussed.

  16. Does the Clearance of Inhaled (99m)Tc-Sestamibi Correlate with Multidrug Resistance Protein 1 Expression in the Human Lung?

    PubMed

    Mohan, Hosahalli K; Routledge, Thomas; Cane, Paul; Livieratos, Lefteris; Ballinger, James R; Peters, Adrien M

    2016-09-01

    Purpose To examine the relation between the lung elimination rate of inhaled technetium 99m ((99m)Tc)-sestamibi and immunohistochemical expression of bronchopulmonary multidrug resistance protein 1 (MRP1) and permeability glycoprotein (P-gp) and assess the repeatability of the inhaled (99m)Tc-sestamibi clearance technique. Materials and Methods (99m)Tc-sestamibi is a known substrate for P-gp and MRP1, which are established cellular drug efflux transporters. The elimination rate of (99m)Tc-sestamibi from the lungs after inhalation as an aerosol has been hypothesized to be regulated by expression of these transporters. Institutional ethics committee approval was received for this prospective study. Written informed consent was obtained from all participants. The clearance of inhaled (99m)Tc-sestamibi from the lungs of 13 patients due to undergo surgery for primary lung cancer (five of 13) or spontaneous pneumothorax (eight of 13) was estimated after dynamic imaging of the lungs during a period of 40 minutes. The time taken to clear 50% of inhaled sestamibi (T1/2) was compared with a semiquantitative immunohistochemical assessment (grade 0-3) of MRP1 and P-gp expression in the lung by using parametric and nonparametric tests. The study was repeated in five participants to assess the repeatability of the technique by using a Bland Altman analysis method. Results MRP1 expression was seen in 12 of 13 patients, while P-gp expression was seen in only two. The mean (99m)Tc-sestamibi elimination rate was faster in patients (n = 6) with low levels of MRP1 expression (grade 0-1) and mean T1/2 of 105 minutes ± 20 (standard deviation), compared with those with higher levels of MRP1 expression (grade 2-3, n = 7) and mean T1/2 of 149 minutes ± 28 (P = .008). Bland-Altman analysis revealed excellent agreement between test and retest values. Conclusion Inhaled (99m)Tc-sestamibi clearance study is a repeatable technique demonstrating significant correlation with MRP1 expression in

  17. Synthesis and characterization of fac-[M(CO)3(P)(OO)] and cis-trans-[M(CO)2(P)2(OO)] complexes (M = Re, (99m)Tc) with acetylacetone and curcumin as OO donor bidentate ligands.

    PubMed

    Triantis, Charalampos; Tsotakos, Theodoros; Tsoukalas, Charalampos; Sagnou, Marina; Raptopoulou, Catherine; Terzis, Aris; Psycharis, Vassilis; Pelecanou, Maria; Pirmettis, Ioannis; Papadopoulos, Minas

    2013-11-18

    The synthesis and characterization of neutral mixed ligand complexes fac-[M(CO)3(P)(OO)] and cis-trans-[M(CO)2(P)2(OO)] (M = Re, (99m)Tc), with deprotonated acetylacetone or curcumin as the OO donor bidentate ligands and a phosphine (triphenylphosphine or methyldiphenylphosphine) as the monodentate P ligand, is described. The complexes were synthesized through the corresponding fac-[M(CO)3(H2O)(OO)] (M = Re, (99m)Tc) intermediate aqua complex. In the presence of phosphine, replacement of the H2O molecule of the intermediate complex at room temperature generates the neutral tricarbonyl monophosphine fac-[Re(CO)3(P)(OO)] complex, while under reflux conditions further replacement of the trans to the phosphine carbonyl generates the new stable dicarbonyl bisphosphine complex cis-trans-[Re(CO)2(P)2(OO)]. The Re complexes were fully characterized by elemental analysis, spectroscopic methods, and X-ray crystallography showing a distorted octahedral geometry around Re. Both the monophosphine and the bisphosphine complexes of curcumin show selective binding to β-amyloid plaques of Alzheimer's disease. At the (99m)Tc tracer level, the same type of complexes, fac-[(99m)Tc(CO)3(P)(OO)] and cis-trans-[(99m)Tc(CO)2(P)2(OO)], are formed introducing new donor combinations for (99m)Tc(I). Overall, β-diketonate and phosphine constitute a versatile ligand combination for Re(I) and (99m)Tc(I), and the successful employment of the multipotent curcumin as β-diketone provides a solid example of the pharmacological potential of this system.

  18. Tc-99m tilmanocept versus Tc-99m sulfur colloid in breast cancer sentinel lymph node identification: Results from a randomized, blinded clinical trial.

    PubMed

    Unkart, Jonathan T; Hosseini, Ava; Wallace, Anne M

    2017-12-01

    No prior trials have compared sentinel lymph node (SLN) identification outcomes between Tc-99m tilmanocept (TcTM) and Tc-99m sulfur colloid (TcSC) in breast cancer (BC). We report on the secondary outcomes from a randomized, double-blinded, single surgeon clinical trial comparing post-injection site pain between TcTM and TcSC. Patients were randomized to receive a preoperative single, peritumoral intradermal injection of TcTM or TcSC. The number of total, "hot", and blue nodes detected and removed were compared between groups. Fifty-two (27-TcSC and 25-TcTM) patients were enrolled and underwent definitive surgical treatment. At least one "hot" SLN was detected in all patients. Three (5.8%) patients had a disease positive-SLN. The total number of SLNs removed was 61 (mean 2.26 (standard deviation (SD) 0.90)) in the TcSC group and 54 (mean 2.16 (SD 0.90)) in the TcTM group, P = 0.69. The total number of "hot" nodes in the TcSC group was 1.96 (SD 0.76) compared to 2.04 (SD 0.73) in the TcTM group, P = 0.71. The number of identified SLNs did not differ significantly between TcTM and TcSC. Given that no significant technical advantages exist between the two agents, surgeons should choose a radiopharmaceutical based on cost and side effect profile. © 2017 Wiley Periodicals, Inc.

  19. Synthesis and characterization of fac-Re(CO)3-aspartic-N-monoacetic acid, a structural analogue of a potential new renal tracer, fac-99mTc(CO)3(ASMA).

    PubMed

    Klenc, Jeffrey; Lipowska, Malgorzata; Taylor, Andrew T; Marzilli, Luigi G

    2012-09-01

    The reaction of an aminopolycarboxylate ligand, as partic- N - m onoacetic a cid (ASMA), with [Re(CO) 3 (H 2 O) 3 ] + was examined. The tridentate coordination of ASMA to this Re I tricarbonyl precursor yielded fac -Re(CO) 3 (ASMA) as a mixture of diastereomers. The chemistry is analogous to that of the Tc I tricarbonyl complex, which yields fac - 99m Tc(CO) 3 (ASMA) under similar conditions. The formation, structure, and isomerization of fac -Re(CO) 3 (ASMA) products were characterized by HPLC, 1 H NMR spectroscopy, and X-ray crystallography. The two major fac -Re(CO) 3 (ASMA) diastereomeric products each have a linear ONO coordination mode with two adjacent five-membered chelate rings, but they differ in the endo or exo orientation of the uncoordinated acetate group, in agreement with expectations based on previous studies. Conditions have been identified for the expedient isomerization of fac -Re(CO) 3 (ASMA) to a mixture consisting primarily of one major product. Because different isomeric species typically have different pharmacokinetic characteristics, these conditions may provide for the practical isolation of a single 99m Tc(CO) 3 (ASMA) species, thus allowing the isolation of the isomer that has optimal imaging and pharmacokinetic characteristics. This information will aid in the design of future 99m Tc radiopharmaceuticals.

  20. Synthesis and characterization of fac-Re(CO)3-aspartic-N-monoacetic acid, a structural analogue of a potential new renal tracer, fac-99mTc(CO)3(ASMA)

    PubMed Central

    Klenc, Jeffrey; Lipowska, Malgorzata; Taylor, Andrew T.; Marzilli, Luigi G.

    2013-01-01

    The reaction of an aminopolycarboxylate ligand, aspartic-N-monoacetic acid (ASMA), with [Re(CO)3(H2O)3]+ was examined. The tridentate coordination of ASMA to this ReI tricarbonyl precursor yielded fac-Re(CO)3(ASMA) as a mixture of diastereomers. The chemistry is analogous to that of the TcI tricarbonyl complex, which yields fac-99mTc(CO)3(ASMA) under similar conditions. The formation, structure, and isomerization of fac-Re(CO)3(ASMA) products were characterized by HPLC, 1H NMR spectroscopy, and X-ray crystallography. The two major fac-Re(CO)3(ASMA) diastereomeric products each have a linear ONO coordination mode with two adjacent five-membered chelate rings, but they differ in the endo or exo orientation of the uncoordinated acetate group, in agreement with expectations based on previous studies. Conditions have been identified for the expedient isomerization of fac-Re(CO)3(ASMA) to a mixture consisting primarily of one major product. Because different isomeric species typically have different pharmacokinetic characteristics, these conditions may provide for the practical isolation of a single 99mTc(CO)3(ASMA) species, thus allowing the isolation of the isomer that has optimal imaging and pharmacokinetic characteristics. This information will aid in the design of future 99mTc radiopharmaceuticals. PMID:24273448

  1. USING TRACERS TO DESCRIBE NAPL HETEROGENEITY

    EPA Science Inventory

    Tracers are frequently used to estimate both the average travel time for water flow through the tracer swept volume and NAPL saturation. The same data can be used to develop a statistical distribution describing the hydraulic conductivity in the sept volume and a possible distri...

  2. Evaluation of the ERP dispersion model using Darlington tracer-study data. Report No. 90-200-K

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wright, S.C.

    1990-01-01

    In this study, site-boundary atmospheric dilution factors calculated by the atmospheric dispersion model used in the ERP (Emergency Response Planning) computer code were compared to data collected during the Darlington tracer study. The purpose of this comparison was to obtain estimates of model uncertainty under a variety of conditions. This report provides background on ERP, the ERP dispersion model and the Darlington tracer study. Model evaluation techniques are discussed briefly, and the results of the comparison of model calculations with the field data are presented and reviewed.

  3. Accounting for pharmacokinetic differences in dual-tracer receptor density imaging

    PubMed Central

    Tichauer, K M; Diop, M; Elliott, J T; Samkoe, K S; Hasan, T; St. Lawrence, K; Pogue, B W

    2014-01-01

    Dual-tracer molecular imaging is a powerful approach to quantify receptor expression in a wide range of tissues by using an untargeted tracer to account for any nonspecific uptake of a molecular-targeted tracer. This approach has previously required the pharmacokinetics of the receptor-targeted and untargeted tracers to be identical, requiring careful selection of an ideal untargeted tracer for any given targeted tracer. In this study, methodology capable of correcting for tracer differences in arterial input functions, as well as binding-independent delivery and retention, is derived and evaluated in a mouse U251 glioma xenograft model using an Affibody tracer targeted to epidermal growth factor receptor (EGFR), a cell membrane receptor overexpressed in many cancers. Simulations demonstrated that blood, and to a lesser extent vascular-permeability, pharmacokinetic differences between targeted and untargeted tracers could be quantified by deconvolving the uptakes of the two tracers in a region of interest devoid of targeted tracer binding, and therefore corrected for, by convolving the uptake of the untargeted tracer in all regions of interest by the product of the deconvolution. Using fluorescently labelled, EGFR-targeted and untargeted Affibodies (known to have different blood clearance rates), the average tumor concentration of EGFR in 4 mice was estimated using dual-tracer kinetic modelling to be 3.9 ± 2.4 nM compared to an expected concentration of 2.0 ± 0.4 nM. However, with deconvolution correction a more equivalent EGFR concentration of 2.0 ± 0.4 nM was measured. PMID:24743262

  4. Accounting for pharmacokinetic differences in dual-tracer receptor density imaging.

    PubMed

    Tichauer, K M; Diop, M; Elliott, J T; Samkoe, K S; Hasan, T; St Lawrence, K; Pogue, B W

    2014-05-21

    Dual-tracer molecular imaging is a powerful approach to quantify receptor expression in a wide range of tissues by using an untargeted tracer to account for any nonspecific uptake of a molecular-targeted tracer. This approach has previously required the pharmacokinetics of the receptor-targeted and untargeted tracers to be identical, requiring careful selection of an ideal untargeted tracer for any given targeted tracer. In this study, methodology capable of correcting for tracer differences in arterial input functions, as well as binding-independent delivery and retention, is derived and evaluated in a mouse U251 glioma xenograft model using an Affibody tracer targeted to epidermal growth factor receptor (EGFR), a cell membrane receptor overexpressed in many cancers. Simulations demonstrated that blood, and to a lesser extent vascular-permeability, pharmacokinetic differences between targeted and untargeted tracers could be quantified by deconvolving the uptakes of the two tracers in a region of interest devoid of targeted tracer binding, and therefore corrected for, by convolving the uptake of the untargeted tracer in all regions of interest by the product of the deconvolution. Using fluorescently labeled, EGFR-targeted and untargeted Affibodies (known to have different blood clearance rates), the average tumor concentration of EGFR in four mice was estimated using dual-tracer kinetic modeling to be 3.9 ± 2.4 nM compared to an expected concentration of 2.0 ± 0.4 nM. However, with deconvolution correction a more equivalent EGFR concentration of 2.0 ± 0.4 nM was measured.

  5. Differential Lung Uptake of 99mTc-HMPAO and 99mTc-Duramycin in the Chronic Hyperoxia Rat Model

    PubMed Central

    Clough, Anne V.; Audi, Said H.; Haworth, Steven T.; Roerig, David L.

    2015-01-01

    Noninvasive radionuclide imaging has the potential to identify and assess mechanisms involved in particular stages of lung injury which occur with acute respiratory distress syndrome, for example. Lung uptake of 99mTc-hexamethylpropyleneamine oxime (HMPAO) is reported to be partially dependent on the redox status of the lung tissue while 99mTc-duramycin, a new marker of cell injury, senses cell death via apoptosis and/or necrosis. Thus, we investigated changes in lung uptake of these agents in rat exposed to hyperoxia for prolonged periods, a common model of acute lung injury. Methods Male Sprague-Dawley rats were pre-exposed to either normoxia (21% O2) or hyperoxia (85% O2) for up to 21 days. For imaging, the rats were anesthetized, injected i.v. with either 99mTc-HMPAO or 99mTc-duramycin (37-74 MBq) and planar images were acquired using a high sensitivity modular gamma camera. Subsequently, 99mTc-macroagreggated albumin (37 MBq, diam=10-40 μm) was injected i.v., imaged, and used to define a lung region-of-interest. The lung to background ratio was used as a measure of lung uptake. Results Hyperoxia exposure resulted in a 74% increase in 99mTc-HMPAO lung uptake, which peaked at 7 days and persisted for the 21 days of exposure. 99mTc-duramycin lung uptake was also maximal at 7 days of exposure but decreased to near control levels by 21 days. The sustained elevation of 99mTc-HMPAO uptake suggests ongoing changes in lung redox status whereas cell death appears to have subsided by 21 days. Conclusion These results suggest the potential use of 99mTc-HMPAO and 99mTc-duramycin as redox and cell-death imaging biomarkers, respectively, for in vivo identification and assessment of different stages of lung injury. PMID:23086010

  6. Positron emission tomography with additional γ-ray detectors for multiple-tracer imaging.

    PubMed

    Fukuchi, Tomonori; Okauchi, Takashi; Shigeta, Mika; Yamamoto, Seiichi; Watanabe, Yasuyoshi; Enomoto, Shuichi

    2017-06-01

    Positron emission tomography (PET) is a useful imaging modality that quantifies the physiological distributions of radiolabeled tracers in vivo in humans and animals. However, this technique is unsuitable for multiple-tracer imaging because the annihilation photons used for PET imaging have a fixed energy regardless of the selection of the radionuclide tracer. This study developed a multi-isotope PET (MI-PET) system and evaluated its imaging performance. Our MI-PET system is composed of a PET system and additional γ-ray detectors. The PET system consists of pixelized gadolinium orthosilicate (GSO) scintillation detectors and has a ring geometry that is 95 mm in diameter with an axial field of view of 37.5 mm. The additional detectors are eight bismuth germanium oxide (BGO) scintillation detectors, each of which is 50 × 50 × 30 mm 3 , arranged into two rings mounted on each side of the PET ring with a 92-mm-inner diameter. This system can distinguish between different tracers using the additional γ-ray detectors to observe prompt γ-rays, which are emitted after positron emission and have an energy intrinsic to each radionuclide. Our system can simultaneously acquire double- (two annihilation photons) and triple- (two annihilation photons and a prompt γ-ray) coincidence events. The system's efficiency for detecting prompt de-excitation γ-rays was measured using a positron-γ emitter, 22 Na. Dual-radionuclide ( 18 F and 22 Na) imaging of a rod phantom and a mouse was performed to demonstrate the performance of the developed system. Our system's basic performance was evaluated by reconstructing two images, one containing both tracers and the other containing just the second tracer, from list-mode data sets that were categorized by the presence or absence of the prompt γ-ray. The maximum detection efficiency for 1275 keV γ-rays emitted from 22 Na was approximately 7% at the scanner's center, and the minimum detection efficiency was 5.1% at the edge of

  7. Heat tracer methods

    USGS Publications Warehouse

    Healy, Richard W.; Scanlon, Bridget R.

    2010-01-01

    The flow of heat in the subsurface is closely linked to the movement of water (Ingebritsen et al., 2006). As such, heat has been used as a tracer in groundwater studies for more than 100 years (Anderson, 2005). As with chemical and isotopic tracers (Chapter 7), spatial or temporal trends in surface and subsurface temperatures can be used to infer rates of water movement. Temperature can be measured accurately, economically, at high frequencies, and without the need to obtain water samples, facts that make heat an attractive tracer. Temperature measurements made over space and time can be used to infer rates of recharge from a stream or other surface water body (Lapham, 1989; Stonestrom and Constantz, 2003); measurements can also be used to estimate rates of steady drainage through depth intervals within thick unsaturated zones (Constantz et al., 2003; Shan and Bodvarsson, 2004). Several thorough reviews of heat as a tracer in hydrologic studies have recently been published (Constantz et al., 2003; Stonestrom and Constantz, 2003; Anderson, 2005; Blasch et al., 2007; Constantz et al., 2008). This chapter summarizes heat-tracer approaches that have been used to estimate recharge.Some clarification in terminology is presented here to avoid confusion in descriptions of the various approaches that follow. Diffuse recharge is that which occurs more or less uniformly across large areas in response to precipitation, infiltration, and drainage through the unsaturated zone. Estimates of diffuse recharge determined using measured temperatures in the unsaturated zone are referred to as potential recharge because it is possible that not all of the water moving through the unsaturated zone will recharge the aquifer; some may be lost to the atmosphere by evaporation or plant transpiration. Estimated fluxes across confining units in the saturated zone are referred to as interaquifer flow (Chapter 1). Focused recharge is that which occurs directly from a point or line source, such

  8. Molybdenum target specifications for cyclotron production of 99mTc based on patient dose estimates.

    PubMed

    Hou, X; Tanguay, J; Buckley, K; Schaffer, P; Bénard, F; Ruth, T J; Celler, A

    2016-01-21

    In response to the recognized fragility of reactor-produced (99)Mo supply, direct production of (99m)Tc via (100)Mo(p,2n)(99m)Tc reaction using medical cyclotrons has been investigated. However, due to the existence of other Molybdenum (Mo) isotopes in the target, in parallel with (99m)Tc, other technetium (Tc) radioactive isotopes (impurities) will be produced. They will be incorporated into the labeled radiopharmaceuticals and result in increased patient dose. The isotopic composition of the target and beam energy are main factors that determine production of impurities, thus also dose increases. Therefore, they both must be considered when selecting targets for clinical (99m)Tc production. Although for any given Mo target, the patient dose can be predicted based on complicated calculations of production yields for each Tc radioisotope, it would be very difficult to reverse these calculations to specify target composition based on dosimetry considerations. In this article, a relationship between patient dosimetry and Mo target composition is studied. A simple and easy algorithm for dose estimation, based solely on the knowledge of target composition and beam energy, is described. Using this algorithm, the patient dose increase due to every Mo isotope that could be present in the target is estimated. Most importantly, a technique to determine Mo target composition thresholds that would meet any given dosimetry requirement is proposed.

  9. Molybdenum target specifications for cyclotron production of 99mTc based on patient dose estimates

    NASA Astrophysics Data System (ADS)

    Hou, X.; Tanguay, J.; Buckley, K.; Schaffer, P.; Bénard, F.; Ruth, T. J.; Celler, A.

    2016-01-01

    In response to the recognized fragility of reactor-produced 99Mo supply, direct production of 99mTc via 100Mo(p,2n)99mTc reaction using medical cyclotrons has been investigated. However, due to the existence of other Molybdenum (Mo) isotopes in the target, in parallel with 99mTc, other technetium (Tc) radioactive isotopes (impurities) will be produced. They will be incorporated into the labeled radiopharmaceuticals and result in increased patient dose. The isotopic composition of the target and beam energy are main factors that determine production of impurities, thus also dose increases. Therefore, they both must be considered when selecting targets for clinical 99mTc production. Although for any given Mo target, the patient dose can be predicted based on complicated calculations of production yields for each Tc radioisotope, it would be very difficult to reverse these calculations to specify target composition based on dosimetry considerations. In this article, a relationship between patient dosimetry and Mo target composition is studied. A simple and easy algorithm for dose estimation, based solely on the knowledge of target composition and beam energy, is described. Using this algorithm, the patient dose increase due to every Mo isotope that could be present in the target is estimated. Most importantly, a technique to determine Mo target composition thresholds that would meet any given dosimetry requirement is proposed.

  10. Time-lapse Mise-á-la-Masse measurements and modeling for tracer test monitoring in a shallow aquifer

    NASA Astrophysics Data System (ADS)

    Perri, Maria Teresa; De Vita, Pantaleone; Masciale, Rita; Portoghese, Ivan; Chirico, Giovanni Battista; Cassiani, Giorgio

    2018-06-01

    The main goal of this study is to evaluate the reliability of the Mise-á-la-Masse (MALM) technique associated with saline tracer tests for the characterization of groundwater flow direction and velocity. The experimental site is located in the upper part of the Alento River alluvial plain (Campania Region, Southern Italy). In this paper we present the hydrogeological setting, the experimental setup and the relevant field results. Subsequently, we compare those data against the simulated results obtained with a 3D resistivity model of the test area, coupled with a model describing the Advection - Dispersion equation for continuous tracer injection. In particular, we calculate a series of 3D forward solutions starting from a reference model, all derived from electrical tomography results, but taking into consideration different values of mean flow velocity and directions. Each electrical resistivity 3D model is used to produce synthetic voltage maps for MALM surveys. Finally, the synthetic MALM voltage maps are compared with the ones measured in the field in order to assess the information content of the MALM dataset with respect to the groundwater field characteristics. The results demonstrate that the information content of the MALM data is sufficient to define important characteristics of the aquifer geometry and properties. This work shows how a combination of three-dimensional time-lapse modeling of flow, tracer transport and electrical current can substantially contribute towards a quantitative interpretation of MALM measurements during a saline tracer test. This approach can thus revive the use of MALM as a practical, low cost field technique for tracer test monitoring and aquifer hydrodynamic characterization.

  11. Seasonal variations of stable carbon isotopic composition of bulk aerosol carbon from Gosan site, Jeju Island in the East China Sea

    NASA Astrophysics Data System (ADS)

    Kundu, Shuvashish; Kawamura, Kimitaka

    2014-09-01

    This study explores the usefulness of stable isotopic composition (δ13C) along with other chemical tracers and air mass trajectory to identify the primary and secondary sources of carbonaceous aerosols. Aerosol samples (n = 84) were collected continuously from April 2003 to April 2004 at Gosan site in Jeju Island, South Korea. The concentrations of total carbon (TC), HCl fumed carbonate-free total carbon (fumed-TC) and their δ13C were measured online using elemental analyzer interfaced to isotope ratio mass spectrometer (EA-IRMS). Similar concentrations of TC and fumed-TC and their similar δ13C values suggest the insignificant contribution of inorganic carbon to Gosan aerosols. The monthly averaged δ13CTC showed the lowest in April/May (-24.2 to -24.4‰), which is related with the highest concentrations of oxalic acid (a secondary tracer). The result indicates an enhanced contribution of TC from secondary sources. The monthly averaged δ13CTC in July/August (-23.0 to -22.5‰) were similar to those in January/February (-23.1‰ to -22.7‰). However, chemical tracers and air mass transport pattern suggest that the pollution source regions in January/February are completely different from those in July/August. Higher δ13C values in July/August are aligned with higher concentration ratios of marine tracers (azelaic acid/TC and methanesulfonate/TC), suggesting an enhanced contribution of marine organic matter to the aerosol loading. Higher δ13C values in January/February are associated with higher concentrations of phthalic acid and K+/TC, indicating more contributions of carbonaceous aerosols from fossil fuel and C4-plant biomass combustion. This study demonstrates that δ13CTC, along with other chemical tracers and air mass trajectory, can be used as a tracer to understand the importance of primary versus secondary pollution sources of carbonaceous aerosols in the atmosphere.

  12. Theoretical Modeling of 99 Tc NMR Chemical Shifts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hall, Gabriel B.; Andersen, Amity; Washton, Nancy M.

    Technetium (Tc) displays a rich chemistry due to the wide range of oxidation states (from -I to +VII) and ability to form coordination compounds. Determination of Tc speciation in complex mixtures is a major challenge, and 99Tc NMR spec-troscopy is widely used to probe chemical environments of Tc in odd oxidation states. However interpretation of the 99Tc NMR data is hindered by the lack of reference compounds. DFT computations can help fill this gap, but to date few com-putational studies have focused on 99Tc NMR of compounds and complexes. This work systematically evaluates the inclu-sion small percentages of Hartree-Fock exchangemore » correlation and relativistic effects in DFT computations to support in-terpretation of the 99Tc NMR spectra. Hybrid functionals are found to perform better than their pure GGA counterparts, and non-relativistic calculations have been found to generally show a lower mean absolute deviation from experiment. Overall non-relativistic PBE0 and B3PW91 calculations are found to most accurately predict 99Tc NMR chemical shifts.« less

  13. Design and utilisation of protocols to characterise dynamic PET uptake of two tracers using basis pursuit.

    PubMed

    Bell, Christopher; Puttick, Simon; Rose, Stephen; Smith, Jye; Thomas, Paul; Dowson, Nicholas

    2017-06-21

    Imaging using more than one biological process using PET could be of great utility, but despite previously proposed approaches to dual-tracer imaging, it is seldom performed. The alternative of performing multiple scans is often infeasible for clinical practice or even in research studies. Dual-tracer PET scanning allows for multiple PET radiotracers to be imaged within the same imaging session. In this paper we describe our approach to utilise the basis pursuit method to aid in the design of dual-tracer PET imaging experiments, and later in separation of the signals. The advantage of this approach is that it does not require a compartment model architecture to be specified or even that both signals are distinguishable in all cases. This means the method for separating dual-tracer signals can be used for many feasible and useful combinations of biology or radiotracer, once an appropriate scanning protocol has been decided upon. Following a demonstration in separating the signals from two consecutively injected radionuclides in a controlled experiment, phantom and list-mode mouse experiments demonstrated the ability to test the feasibility of dual-tracer imaging protocols for multiple injection delays. Increases in variances predicted for kinetic macro-parameters V D and K I in brain and tumoral tissue were obtained when separating the synthetically combined data. These experiments confirmed previous work using other approaches that injections delays of 10-20 min ensured increases in variance were kept minimal for the test tracers used. On this basis, an actual dual-tracer experiment using a 20 min delay was performed using these radio tracers, with the kinetic parameters (V D and K I ) extracted for each tracer in agreement with the literature. This study supports previous work that dual-tracer PET imaging can be accomplished provided certain constraints are adhered to. The utilisation of basis pursuit techniques, with its removed need to specify a model

  14. Design and utilisation of protocols to characterise dynamic PET uptake of two tracers using basis pursuit

    NASA Astrophysics Data System (ADS)

    Bell, Christopher; Puttick, Simon; Rose, Stephen; Smith, Jye; Thomas, Paul; Dowson, Nicholas

    2017-06-01

    Imaging using more than one biological process using PET could be of great utility, but despite previously proposed approaches to dual-tracer imaging, it is seldom performed. The alternative of performing multiple scans is often infeasible for clinical practice or even in research studies. Dual-tracer PET scanning allows for multiple PET radiotracers to be imaged within the same imaging session. In this paper we describe our approach to utilise the basis pursuit method to aid in the design of dual-tracer PET imaging experiments, and later in separation of the signals. The advantage of this approach is that it does not require a compartment model architecture to be specified or even that both signals are distinguishable in all cases. This means the method for separating dual-tracer signals can be used for many feasible and useful combinations of biology or radiotracer, once an appropriate scanning protocol has been decided upon. Following a demonstration in separating the signals from two consecutively injected radionuclides in a controlled experiment, phantom and list-mode mouse experiments demonstrated the ability to test the feasibility of dual-tracer imaging protocols for multiple injection delays. Increases in variances predicted for kinetic macro-parameters V D and K I in brain and tumoral tissue were obtained when separating the synthetically combined data. These experiments confirmed previous work using other approaches that injections delays of 10-20 min ensured increases in variance were kept minimal for the test tracers used. On this basis, an actual dual-tracer experiment using a 20 min delay was performed using these radio tracers, with the kinetic parameters (V D and K I) extracted for each tracer in agreement with the literature. This study supports previous work that dual-tracer PET imaging can be accomplished provided certain constraints are adhered to. The utilisation of basis pursuit techniques, with its removed need to specify a model

  15. Which metabolic imaging, besides bone scan with 99mTc-phosphonates, for detecting and evaluating bone metastases in prostatic cancer patients? An open discussion.

    PubMed

    Bombardieri, E; Setti, L; Kirienko, M; Antunovic, L; Guglielmo, P; Ciocia, G

    2015-12-01

    Prostate cancer bone metastases occur frequently in advanced cancer and this is matter of particular attention, due to the great impact on patient's management and considering that a lot of new emerging therapeutic options have been recently introduced. Imaging bone metastases is essential to localize lesions, to establish their size and number, to study characteristics and changes during therapy. Besides radiological imaging, nuclear medicine modalities can image their features and offer additional information about their metabolic behaviour. They can be classified according to physical characteristics, type of detection, mechanism of uptake, availability for daily use. The physiopathology of metastases formation and the mechanisms of tracer uptake are essential to understand the interpretation of nuclear medicine images. Therefore, radiopharmaceuticals for bone metastases can be classified in agents targeting bone (99mTc-phosphonates, 18F-fluoride) and those targeting prostatic cancer cells (18F-fluoromethylcholine, 11C-choline, 18F-fluorodeoxyglucose). The modalities using the first group of tracers are planar bone scan, SPECT or SPECT/CT with 99mTc-diphosphonates, and 18F-fluoride PET/CT, while the modalities using the second group include 18F/11C-choline derivatives PET/CT, 18F-FDG PET/CT and PET/CT scans with several other radiopharmaceuticals described in the literature, such as 18F/11C-acetate derivatives, 18F-fluoro-5α-dihydrotestosterone (FDHT), 18F-anti-1-amino-3-fluorocyclobutane-1-carboxylic acid (FACBC), 18F-2'-fluoro-5-methyl-1-β-D-arabinofuranosyluracil (FMAU) and 68Ga-labeled-prostate specific membrane antigen (PMSA) PET/TC. However, since data on clinical validation for these last novel modalities are not conclusive and/or are not still sufficient in number, at present they can be still considered as promising tools under evaluation. The present paper considers the nuclear modalities today available for the clinical routine. This overview wants

  16. Mental Health and the TC. Chapter 5.

    ERIC Educational Resources Information Center

    Acampora, Alfonso P., Ed.; Nebelkopf, Ethan, Ed.

    This document contains 19 papers from the ninth World Conference of Therapeutic Communities (TCs) that deal with the interface between the mental health establishments and the TC. Papers include: (1) "Psychiatry and the TC" (Jerome Jaffe); (2) "The Chemical Brain" (Sidney Cohen); (3) "Where Does the TC Fail?" (Ab…

  17. Quantitative scintigraphy in diagnosis and management of plantar fasciitis (Calcaneal periostitis): concise communication

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sewell, J.R.; Black, C.M.; Chapman, A.H.

    1980-07-01

    We have found that Tc-99m methylene diphosphonate imaging of the heel is of diagnostic value in the painful heel syndrome, permitting positive identification of the site of inflammation in cases where radiography is unhelpful. With this technique, tracer uptake in the heel is susceptible to quantification, allowing a serial and objective assessment of response to therapy.

  18. Stable isotope tracer dilution for quantifying very low-density lipoprotein-triacylglycerol kinetics in man.

    PubMed

    Sidossis, Labros S; Magkos, Faidon; Mittendorfer, Bettina; Wolfe, Robert R

    2004-08-01

    A number of approaches have been employed in the past to measure very low-density lipoprotein (VLDL) triacylglycerol (TG) kinetics in humans in vivo, varying in the selection of tracer and mode of administration. All, however, make use of labeled TG precursors and more or less complicated mathematical models to derive the kinetic parameters of interest. The aim of the present study was to develop a conceptually straightforward method, based on the traditional tracer infusion technique, for quantifying VLDL-TG production rates in man using stable isotopes. Our approach involves ingestion of [U-13C3]glycerol to endogenously label the glycerol in VLDL-TG, plasmapheresis, isolation of the newly 13C-labeled VLDL from plasma, and administration within the next 2-3 days via a primed constant autologous reinfusion. This procedure produces enough tracer for a priming dose plus 2-3 h of infusion. In the physiological conditions examined (basal and hyperglycemic states, fat- and carbohydrate-rich diets), with almost 3-fold ranging VLDL-TG pool sizes, a steady state in plasma VLDL-TG glycerol tracer-to-tracee ratio was readily achieved within 2 h. Consequently, calculations are made according to the isotope dilution principle, thus avoiding assumptions implicit in more complicated models. The stable isotope VLDL-TG tracer dilution method offers an alternative and reliable tool for the determination of endogenous VLDL-TG kinetics in man under a variety of metabolic states. Copyright 2003 Elsevier Ltd.

  19. Tracking tracer breakthrough in the hyporheic zone using time‐lapse DC resistivity, Crabby Creek, Pennsylvania

    USGS Publications Warehouse

    Nyquist, Jonathan E.; Toran, Laura; Fang, Allison C.; Ryan, Robert J.; Rosenberry, Donald O.

    2010-01-01

    Characterization of the hyporheic zone is of critical importance for understanding stream ecology, contaminant transport, and groundwater‐surface water interaction. A salt water tracer test was used to probe the hyporheic zone of a recently re‐engineered portion of Crabby Creek, a stream located near Philadelphia, PA. The tracer solution was tracked through a 13.5 meter segment of the stream using both a network of 25 wells sampled every 5–15 minutes and time‐lapse electrical resistivity tomographs collected every 11 minutes for six hours, with additional tomographs collected every 100 minutes for an additional 16 hours. The comparison of tracer monitoring methods is of keen interest because tracer tests are one of the few techniques available for characterizing this dynamic zone, and logistically it is far easier to collect resistivity tomographs than to install and monitor a dense network of wells. Our results show that resistivity monitoring captured the essential shape of the breakthrough curve and may indicate portions of the stream where the tracer lingered in the hyporheic zone. Time‐lapse resistivity measurements, however, represent time averages over the period required to collect a tomographic data set, and spatial averages over a volume larger than captured by a well sample. Smoothing by the resistivity data inversion algorithm further blurs the resulting tomograph; consequently resistivity monitoring underestimates the degree of fine‐scale heterogeneity in the hyporheic zone.

  20. Conducting a Surgical Site Infection Prevention Tracer.

    PubMed

    Padgette, Polly; Wood, Brittain

    2018-05-01

    Surgical site infections (SSIs) are the most common health care-associated infections in patients. Approximately half of SSIs are preventable when using evidence-based strategies; however, deviations from evidence-based practice can occur over time. Infection preventionists and perioperative staff members can help prevent these deviations by observing staff member practices using tracer methodology. Tracer methodology uses clinical information to follow patient care, treatment, or services provided throughout the care delivery system. The goal of tracer methodology for SSI prevention is to validate that organizational processes are promoting safer patient care. Using tracers, perioperative and infection prevention staff members can develop strategies to eliminate deviations from evidence-based practice, thereby helping to prevent SSIs and improve patient outcomes. © AORN, Inc, 2018.

  1. Many Paths to Skilled Employment: A Reverse Tracer Study of Seven Occupations in Colombia.

    ERIC Educational Resources Information Center

    Ziderman, Adrian; Horn, Robin

    1995-01-01

    Employs reverse tracer techniques to identify alternative training paths for selected skilled and semiskilled occupations in Colombia. Shows that workers pursue various alternative training paths to acquire essential occupational skills. Strong public intervention in training markets should be discouraged, as choices would be narrowed and the…

  2. Measurement of variation in soil solute tracer concentration across a range of effective pore sizes

    USGS Publications Warehouse

    Harvey, Judson W.

    1993-01-01

    Solute transport concepts in soil are based on speculation that solutes are distributed nonuniformly within large and small pores. Solute concentrations have not previously been measured across a range of pore sizes and examined in relation to soil hydrological properties. For this study, modified pressure cells were used to measure variation in concentration of a solute tracer across a range of pore sizes. Intact cores were removed from the site of a field tracer experiment, and soil water was eluted from 10 or more discrete classes of pore size. Simultaneous changes in water content and unsaturated hydraulic conductivity were determined on cores using standard pressure cell techniques. Bromide tracer concentration varied by as much as 100% across the range of pore sizes sampled. Immediately following application of the bromide tracer on field plots, bromide was most concentrated in the largest pores; concentrations were lower in pores of progressively smaller sizes. After 27 days, bromide was most dilute in the largest pores and concentrations were higher in the smaller pores. A sharp, threefold decrease in specific water capacity during elution indicated separation of two major pore size classes at a pressure of 47 cm H2O and a corresponding effective pore diameter of 70 μm. Variation in tracer concentration, on the other hand, was spread across the entire range of pore sizes investigated in this study. A two-porosity characterization of the transport domain, based on water retention criteria, only broadly characterized the pattern of variation in tracer concentration across pore size classes during transport through a macroporous soil.

  3. High Tc screen-printed YBa2Cu3O(7-x) films - Effect of the substrate material

    NASA Astrophysics Data System (ADS)

    Bansal, Narottam P.; Simons, Rainee N.; Farrell, D. E.

    1988-08-01

    Thick films of YBa2Cu3O(7-x) have been deposited on highly polished alumina, magnesia spinel, nickel aluminum titanate (Ni-Al-Ti), and barium tetratitanate (Ba-Ti) substrates by the screen printing technique. Properties of the films were found to be highly sensitive to the choice of the substrate material. The film on Ba-Ti turned green after firing, due to a reaction with the substrate and were insulating. A film on Ni-Al-Ti had a Tc (onset) of about 95 K and lost 90 percent of its resistance by about 75 K. However, even at 4 K it was not fully superconducting, possibly due to a reaction between the film and the substrate and interdiffusion of the reaction products. The film on alumina had Tc (onset) of about 96 K, Tc (zero) of about 66 K, and Delta Tc of about 10 K. The best film was obtained on spinel and had Tc (onset) of about 94 K, zero resistance at 81 K, and a transition width of about 7 K.

  4. High Tc screen-printed YBa2Cu3O(7-x) films - Effect of the substrate material

    NASA Technical Reports Server (NTRS)

    Bansal, Narottam P.; Simons, Rainee N.; Farrell, D. E.

    1988-01-01

    Thick films of YBa2Cu3O(7-x) have been deposited on highly polished alumina, magnesia spinel, nickel aluminum titanate (Ni-Al-Ti), and barium tetratitanate (Ba-Ti) substrates by the screen printing technique. Properties of the films were found to be highly sensitive to the choice of the substrate material. The film on Ba-Ti turned green after firing, due to a reaction with the substrate and were insulating. A film on Ni-Al-Ti had a Tc (onset) of about 95 K and lost 90 percent of its resistance by about 75 K. However, even at 4 K it was not fully superconducting, possibly due to a reaction between the film and the substrate and interdiffusion of the reaction products. The film on alumina had Tc (onset) of about 96 K, Tc (zero) of about 66 K, and Delta Tc of about 10 K. The best film was obtained on spinel and had Tc (onset) of about 94 K, zero resistance at 81 K, and a transition width of about 7 K.

  5. Quantitative measurement of binary liquid distributions using multiple-tracer x-ray fluorescence and radiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Halls, Benjamin R.; Meyer, Terrence R.; Kastengren, Alan L.

    2015-01-01

    The complex geometry and large index-of-refraction gradients that occur near the point of impingement of binary liquid jets present a challenging environment for optical interrogation. A simultaneous quadruple-tracer x-ray fluorescence and line-of-sight radiography technique is proposed as a means of distinguishing and quantifying individual liquid component distributions prior to, during, and after jet impact. Two different pairs of fluorescence tracers are seeded into each liquid stream to maximize their attenuation ratio for reabsorption correction and differentiation of the two fluids during mixing. This approach for instantaneous correction of x-ray fluorescence reabsorption is compared with a more time-intensive approach of usingmore » stereographic reconstruction of x-ray attenuation along multiple lines of sight. The proposed methodology addresses the need for a quantitative measurement technique capable of interrogating optically complex, near-field liquid distributions in many mixing systems of practical interest involving two or more liquid streams.« less

  6. Quantitative measurement of binary liquid distributions using multiple-tracer x-ray fluorescence and radiography

    DOE PAGES

    Halls, Benjamin R.; Meyer, Terrence R.; Kastengren, Alan L.

    2015-01-23

    The complex geometry and large index-of-refraction gradients that occur near the point of impingement of binary liquid jets present a challenging environment for optical interrogation. A simultaneous quadruple-tracer x-ray fluorescence and line-of-sight radiography technique is proposed as a means of distinguishing and quantifying individual liquid component distributions prior to, during, and after jet impact. Two different pairs of fluorescence tracers are seeded into each liquid stream to maximize their attenuation ratio for reabsorption correction and differentiation of the two fluids during mixing. This approach for instantaneous correction of x-ray fluorescence reabsorption is compared with a more time-intensive approach of usingmore » stereographic reconstruction of x-ray attenuation along multiple lines of sight. The proposed methodology addresses the need for a quantitative measurement technique capable of interrogating optically complex, near-field liquid distributions in many mixing systems of practical interest involving two or more liquid streams.« less

  7. Stereo electroencephalography-guided radiofrequency thermocoagulation (SEEG-guided RF-TC) in drug-resistant focal epilepsy: Results from a 10-year experience.

    PubMed

    Bourdillon, Pierre; Isnard, Jean; Catenoix, Hélène; Montavont, Alexandra; Rheims, Sylvain; Ryvlin, Philippe; Ostrowsky-Coste, Karine; Mauguiere, François; Guénot, Marc

    2017-01-01

    Stereo electroencephalography (SEEG)-guided radiofrequency thermocoagulation (SEEG-guided RF-TC) has been proposed since 2004 as a possible treatment of some focal drug-resistant epilepsy. The aim of this study is to provide extensive data about efficacy and safety of SEEG-guided RF-TC. Over a 10-year period, 162 patients with drug-resistant focal epilepsy were eligible for SEEG-guided RF-TG during phase II invasive investigation by SEEG. All follow-up and safety data were collected prospectively. The primary outcome was seizure freedom at 2 months and at 1 year after SEEG-guided RF-TC. Secondary outcomes were the responders' rate (patient with at least 50% decrease in seizure frequency) and their long-term follow-up. Twenty-five percent of patients were seizure-free at 2 months and 7% at 1 year. We reported 67% of responders at 2 months and 48% at 1 year; 58% of responders maintained their status during the long-term follow-up. The seizure outcome was significantly better when the SEEG-guided RF-TC involved the occipital region (p = 0.007). When surgery followed an SEEG-guided RF-TC, the positive predictive value of being a responder 2 months after an SEEG-guided RF-TC and to be Engel's class I or II after surgery was 93%. We reported 1.1% of permanent deficit and 2.4% of transient side effects. Our results, gathered in a large population over a 10-year period, confirm that SEEG-guided RF-TC is a safe technique, being efficient in many cases. More than two thirds of patients showed a short-term improvement, and almost half of them were responders at 1-year follow-up. The technique appears to be especially interesting for limited epileptic zone inaccessible to surgery and when epilepsy is related to a large unilateral network (network disruption by multiple RF-TC). Furthermore, SEEG-guided RF-TC effect is a predictor of outcome after conventional cortectomy in patients eligible for surgery. Wiley Periodicals, Inc. © 2016 International League Against Epilepsy.

  8. A review of radioactive isotopes and other residence time tracers in understanding groundwater recharge: Possibilities, challenges, and limitations

    NASA Astrophysics Data System (ADS)

    Cartwright, Ian; Cendón, Dioni; Currell, Matthew; Meredith, Karina

    2017-12-01

    Documenting the location and magnitude of groundwater recharge is critical for understanding groundwater flow systems. Radioactive tracers, notably 14C, 3H, 36Cl, and the noble gases, together with other tracers whose concentrations vary over time, such as the chlorofluorocarbons or sulfur hexafluoride, are commonly used to estimate recharge rates. This review discusses some of the advantages and problems of using these tracers to estimate recharge rates. The suite of tracers allows recharge to be estimated over timescales ranging from a few years to several hundred thousand years, which allows both the long-term and modern behaviour of groundwater systems to be documented. All tracers record mean residence times and mean recharge rates rather than a specific age and date of recharge. The timescale over which recharge rates are averaged increases with the mean residence time. This is an advantage in providing representative recharge rates but presents a problem in comparing recharge rates derived from these tracers with those from other techniques, such as water table fluctuations or lysimeters. In addition to issues relating to the sampling and interpretation of specific tracers, macroscopic dispersion and mixing in groundwater flow systems limit how precisely groundwater residence times and recharge rates may be estimated. Additionally, many recharge studies have utilised existing infrastructure that may not be ideal for this purpose (e.g., wells with long screens that sample groundwater several kilometres from the recharge area). Ideal recharge studies would collect sufficient information to optimise the use of specific tracers and minimise the problems of mixing and dispersion.

  9. Observations of axisymmetric tracer particle orientation during flow through a dilute fixed bed of fibers

    NASA Astrophysics Data System (ADS)

    Frattini, Paul L.; Shaqfeh, Eric S. G.; Levy, Jeffrey L.; Koch, Donald L.

    1991-11-01

    Direct microstructural evidence for net tracer particle orientation induced solely by hydrodynamic interactions in a dilute, disordered, fibrous media is reported. A dilute fixed bed of randomly placed fibers was constructed and glycerol/water suspensions of either synthetic akaganeite (βFeOOH, average aspect ratio 6.3) or hematite (αFe2O3, average aspect ratio 1.6) tracer particles were made to flow axially through the bed at prescribed flow rates. Conservative linear dichroism, a noninvasive light scattering technique, was employed to provide a direct measure of the orientational order parameter for the tracer particle population at the end of the bed. The effect of Brownian motion on the hydrodynamically induced order in the suspensions was studied over three orders of magnitude in scaled rotary Peclet number, 5tracer populations were investigated and compared qualitatively to theoretically derived bounds.

  10. Pressure and high-Tc superconductivity in sulfur hydrides.

    PubMed

    Gor'kov, Lev P; Kresin, Vladimir Z

    2016-05-11

    The paper discusses fundamentals of record-TC superconductivity discovered under high pressure in sulfur hydride. The rapid increase of TC with pressure in the vicinity of Pcr ≈ 123GPa is interpreted as the fingerprint of a first-order structural transition. Based on the cubic symmetry of the high-TC phase, it is argued that the lower-TC phase has a different periodicity, possibly related to an instability with a commensurate structural vector. In addition to the acoustic branches, the phonon spectrum of H3S contains hydrogen modes with much higher frequencies. Because of the complex spectrum, usual methods of calculating TC are here inapplicable. A modified approach is formulated and shown to provide realistic values for TC and to determine the relative contributions of optical and acoustic branches. The isotope effect (change of TC upon Deuterium for Hydrogen substitution) originates from high frequency phonons and differs in the two phases. The decrease of TC following its maximum in the high-TC phase is a sign of intermixing with pairing at hole-like pockets which arise in the energy spectrum of the cubic phase at the structural transition. On-pockets pairing leads to the appearance of a second gap and is remarkable for its non-adiabatic regime: hydrogen mode frequencies are comparable to the Fermi energy.

  11. Tuning structure and mobility of solvation shells surrounding tracer additives.

    PubMed

    Carmer, James; Jain, Avni; Bollinger, Jonathan A; van Swol, Frank; Truskett, Thomas M

    2015-03-28

    Molecular dynamics simulations and a stochastic Fokker-Planck equation based approach are used to illuminate how position-dependent solvent mobility near one or more tracer particle(s) is affected when tracer-solvent interactions are rationally modified to affect corresponding solvation structure. For tracers in a dense hard-sphere fluid, we compare two types of tracer-solvent interactions: (1) a hard-sphere-like interaction, and (2) a soft repulsion extending beyond the hard core designed via statistical mechanical theory to enhance tracer mobility at infinite dilution by suppressing coordination-shell structure [Carmer et al., Soft Matter 8, 4083-4089 (2012)]. For the latter case, we show that the mobility of surrounding solvent particles is also increased by addition of the soft repulsive interaction, which helps to rationalize the mechanism underlying the tracer's enhanced diffusivity. However, if multiple tracer surfaces are in closer proximity (as at higher tracer concentrations), similar interactions that disrupt local solvation structure instead suppress the position-dependent solvent dynamics.

  12. MO-F-CAMPUS-I-05: Radiation Dosimetry of 99mTc-IDA-D-[c(RGDfK)]2, a SPECT Agent for Angiogenesis Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, J

    2015-06-15

    Purpose: Tc-99m labeled IDA-D-[c(RGDfK){sub 2} ( {sup 99m}Tc-RGD) is a recently developed radiotracer for gamma camera or single photon emission computed tomography (SPECT) imaging and promising agent for the visualization of angiogenesis. In this study, we investigated the internal radiation dosimetry of {sup 99m}Tc-RGD in humans. Methods: Six normal controls (F:M=4:2; 68.3±3.2 years; 56.5±10.7 kg) were participated in this study. Simultaneous anterior and posterior scans of whole-body were performed using dual head gamma camera system. Before the emission scan, transmission scan was performed just before injection of {sup 99m}Tc-RGD using Co-57 flood source. After an intravenous injection of 388.7±29.3 MBqmore » of {sup 99m}Tc-RGD, six serial emission scans were performed at 0, 1, 2, 4, 8 and 24 hours post-injection. The anterior and posterior images were geometrically averaged and attenuation correction was applied using transmission scan image. Regions of interest (ROIs) were drawn on liver, gallbladder, kidneys, urinary bladder, spleen, brain, and large intestine. Time activity curves were obtained from serial emission scan and ROIs. The number of disintegrations per unit activity administered (residence time) were calculated from the area under the curve of time activity curves and injected dose of each patient. Finally, the radiation dose for each organ and effective doses were obtained using OLINDA/EXM 1.1 software and residence time. Results: High radiation doses were reported on renal and biliary excretion tracks such as urinary bladder wall, upper large intestine, kidneys, liver and gallbladder wall and their doses were 19.15±6.84, 19.28±4.78, 15.67±0.90, 9.13±1.71 and 9.09±2.03 µGy/MBq, respectively. The effective dose and effective dose equivalent were 5.08±0.53 and 7.11±0.58 µSv/MBq, respectively. Conclusion: We evaluated the radiation dose of 99mTc-RGD, which has an acceptable effective radiation dose compare to the other Tc-99m labeled

  13. 99mTc-EDDA/HYNIC-octreotate scintigraphy, an efficient method for the detection and staging of carcinoid tumours: results of 3 years' experience.

    PubMed

    Hubalewska-Dydejczyk, A; Fröss-Baron, K; Mikołajczak, R; Maecke, H R; Huszno, B; Pach, D; Sowa-Staszczak, A; Janota, B; Szybiński, P; Kulig, J

    2006-10-01

    At all stages of the disease, serious difficulties are encountered in the imaging diagnosis of carcinoids. Somatostatin receptor scintigraphy (SRS) holds great promise for detecting primary tumours and metastases. 99mTc-EDDA/HYNIC-octreotate should significantly improve the diagnosis of carcinoids in comparison with 111In-Octreoscan owing to the better affinity for SSR2 and the higher count rate. The aim of this study was to assess the diagnostic efficiency of 99mTc-EDDA/HYNIC-octreotate scintigraphy in the detection and staging of carcinoid tumours. The study population comprised 75 patients (age 48.5+/-15.5 years): 46 with histological confirmation of carcinoid and 29 with suspected disease. 99mTc-EDDA/HYNIC-octreotate (740 MBq) SRS and CT were performed in all patients. Fifteen patients were examined with 111In-Octreoscan. High-quality 99mTc-EDDA/HYNIC-octreotate images were obtained in all cases, with maximum tumour tracer accumulation 4 h p.i. The mean target/non-target ratios for whole body (WB) and SPECT scans were, respectively, as follows: primary lesions: 4.5 and 10.2; metastases: liver, 3.1 and 12.3; abdominal focal lesions, 2.7 and 5.8; lung, 2.7 and 8.3; mediastinum, 3.4 and 7.6; bones, 6.8 and 19.0. 99mTc-EDDA/HYNIC-octreotate WB scans revealed more metastases than 111In-Octreoscan, with better individual separation. 99mTc-EDDA/HYNIC-octreotate SRS revealed new metastatic lesions in seven patients with confirmed carcinoid, and in four with dissemination the primary focus was found. Five patients qualified for radioguided surgery and 11 were referred to 90Y-DOTA-TATE therapy. The sensitivity of SRS in comparison with CT was higher for primary lesions and liver and abdominal lymph node metastases. In the subgroup of patients with suspected neuroendocrine tumours, two duodenal carcinoids, one thymic carcinoid and one ileal carcinoid were found. 99mTc-EDDA/HYNIC-octreotate, with high imaging quality, is an excellent alternative to 111In-Octreoscan for

  14. Pre-clinical and Clinical Evaluation of High Resolution, Mobile Gamma Camera and Positron Imaging Devices

    DTIC Science & Technology

    2009-10-01

    Field-of-View, Mobile PET/SPECT System for Bedside Environments: A Dynamic Cardiac Phantom Study using 99mTc and 18F- FDG . Presented at the American...using Tc-99m tracers and viability imaging using F- 18 tracers [3]-[7]. For cardiac F-18 imaging in a bedside environment, the 511 keV SPECT approach...SPECT system may have difficulty imaging subtle myocardial defects with F-18 tracers , but it may effectively image moderate to severe defects. The

  15. Dual-tracer background subtraction approach for fluorescent molecular tomography

    PubMed Central

    Holt, Robert W.; El-Ghussein, Fadi; Davis, Scott C.; Samkoe, Kimberley S.; Gunn, Jason R.; Leblond, Frederic

    2013-01-01

    Abstract. Diffuse fluorescence tomography requires high contrast-to-background ratios to accurately reconstruct inclusions of interest. This is a problem when imaging the uptake of fluorescently labeled molecularly targeted tracers in tissue, which can result in high levels of heterogeneously distributed background uptake. We present a dual-tracer background subtraction approach, wherein signal from the uptake of an untargeted tracer is subtracted from targeted tracer signal prior to image reconstruction, resulting in maps of targeted tracer binding. The approach is demonstrated in simulations, a phantom study, and in a mouse glioma imaging study, demonstrating substantial improvement over conventional and homogenous background subtraction image reconstruction approaches. PMID:23292612

  16. Microstructural characterization and tribological behavior of surface plasma Zr-Er alloying on TC11 alloy

    NASA Astrophysics Data System (ADS)

    Wei, Dongbo; Zhang, Pingze; Liu, Yingchao; Chen, Xiaohu; Ding, Feng; Li, Fengkun

    2018-02-01

    The Zr coating and Zr-Er coating are grown on TC11 substrate by double-glow plasma surface metallurgy technique, followed by the wear tests at ambient temperature and 500 °C. The data of nanohardness and elastic modulus of the samples are collected by the nano-indentation test. The adhesion strength of coatings is investigated by means of the scratch test. The study of wear resistance is performed using a ball-on-disc wear test system by running against the Si3N4 ball and measured by scanning electron microscope (SEM) and X-ray diffraction (XRD). Experimental results indicate that the nanohardness of the Zr coating and Zr-Er coating are 5.94 GPa and 7.98 GPa, respectively, which are 1.79 times and 2.41 times greater than that of TC11 substrate. Zr coating and Zr-Er coating realize the metallurgical bonding with TC11 substrate with continuous and compact structure. Compared with the Zr coating and TC11, the Zr-Er coating presents the lowest specific wear rates, which are 1.689 × 10-6 mm3 Nm-1 and 1.851 × 10-6 mm3 Nm-1 at ambient temperature and 500 °C respectively, indicating the excellent and improved wear resistance of TC11.

  17. Impeding 99Tc(IV) mobility in novel waste forms

    DOE PAGES

    Lee, Mal-Soon; Um, Wooyong; Wang, Guohui; ...

    2016-06-30

    Technetium ( 99Tc) is a long-lived radioactive fission product whose mobility in the subsurface is largely governed by its oxidation state1. Immobilization of Tc in mineral substrates is crucial for radioactive waste management and environmental remediation. Tc(IV) incorporation in spinels2, 3 has been proposed as a novel method to increase Tc retention in glass waste forms. However, experiments with Tc-magnetite under high temperature and oxic conditions showed re-oxidation of Tc(IV) to volatile pertechnetate Tc(VII)O4-.4, 5 Here we address this problem with large-scale ab initio molecular dynamics simulations and propose that elevated temperatures, 1st row transition metal dopants can significantly enhancemore » Tc retention in the order Co > Zn > Ni. Experiments with doped spinels at T=700 ºC provided quantitative confirmation of increased Tc retention in the same order predicted by theory. This work highlights the power of modern state-of-the-art simulations to provide essential insights and generate bottom-up design criteria of complex oxide materials at elevated temperatures.« less

  18. Hyperpolarized functional magnetic resonance of murine skeletal muscle enabled by multiple tracer-paradigm synchronizations.

    PubMed

    Leftin, Avigdor; Roussel, Tangi; Frydman, Lucio

    2014-01-01

    Measuring metabolism's time- and space-dependent responses upon stimulation lies at the core of functional magnetic resonance imaging. While focusing on water's sole resonance, further insight could arise from monitoring the temporal responses arising from the metabolites themselves, in what is known as functional magnetic resonance spectroscopy. Performing these measurements in real time, however, is severely challenged by the short functional timescales and low concentrations of natural metabolites. Dissolution dynamic nuclear polarization is an emerging technique that can potentially alleviate this, as it provides a massive sensitivity enhancement allowing one to probe low-concentration tracers and products in a single-scan. Still, conventional implementations of this hyperpolarization approach are not immediately amenable to the repeated acquisitions needed in real-time functional settings. This work proposes a strategy for functional magnetic resonance of hyperpolarized metabolites that bypasses this limitation, and enables the observation of real-time metabolic changes through the synchronization of stimuli-triggered, multiple-bolus injections of the metabolic tracer 13C1-pyruvate. This new approach is demonstrated with paradigms tailored to reveal in vivo thresholds of murine hind-limb skeletal muscle activation, involving the conversion of 13C1-pyruvate to 13C1-lactate and 13C1-alanine. These functional hind-limb studies revealed that graded skeletal muscle stimulation causes commensurate increases in glycolytic metabolism in a frequency- and amplitude-dependent fashion, that can be monitored on the seconds/minutes timescale using dissolution dynamic nuclear polarization. Spectroscopic imaging further allowed the in vivo visualization of uptake, transformation and distribution of the tracer and products, in fast-twitch glycolytic and in slow-twitch oxidative muscle fiber groups. While these studies open vistas in time and sensitivity for metabolic

  19. Combined use of heat and saline tracer to estimate aquifer properties in a forced gradient test

    NASA Astrophysics Data System (ADS)

    Colombani, N.; Giambastiani, B. M. S.; Mastrocicco, M.

    2015-06-01

    Usually electrolytic tracers are employed for subsurface characterization, but the interpretation of tracer test data collected by low cost techniques, such as electrical conductivity logging, can be biased by cation exchange reactions. To characterize the aquifer transport properties a saline and heat forced gradient test was employed. The field site, located near Ferrara (Northern Italy), is a well characterized site, which covers an area of 200 m2 and is equipped with a grid of 13 monitoring wells. A two-well (injection and pumping) system was employed to perform the forced gradient test and a straddle packer was installed in the injection well to avoid in-well artificial mixing. The contemporary continuous monitor of hydraulic head, electrical conductivity and temperature within the wells permitted to obtain a robust dataset, which was then used to accurately simulate injection conditions, to calibrate a 3D transient flow and transport model and to obtain aquifer properties at small scale. The transient groundwater flow and solute-heat transport model was built using SEAWAT. The result significance was further investigated by comparing the results with already published column experiments and a natural gradient tracer test performed in the same field. The test procedure shown here can provide a fast and low cost technique to characterize coarse grain aquifer properties, although some limitations can be highlighted, such as the small value of the dispersion coefficient compared to values obtained by natural gradient tracer test, or the fast depletion of heat signal due to high thermal diffusivity.

  20. Journal: A Review of Some Tracer-Test Design Equations for ...

    EPA Pesticide Factsheets

    Determination of necessary tracer mass, initial sample-collection time, and subsequent sample-collection frequency are the three most difficult aspects to estimate for a proposed tracer test prior to conducting the tracer test. To facilitate tracer-mass estimation, 33 mass-estimation equations are reviewed here, 32 of which were evaluated using previously published tracer-test design examination parameters. Comparison of the results produced a wide range of estimated tracer mass, but no means is available by which one equation may be reasonably selected over the others. Each equation produces a simple approximation for tracer mass. Most of the equations are based primarily on estimates or measurements of discharge, transport distance, and suspected transport times. Although the basic field parameters commonly employed are appropriate for estimating tracer mass, the 33 equations are problematic in that they were all probably based on the original developers' experience in a particular field area and not necessarily on measured hydraulic parameters or solute-transport theory. Suggested sampling frequencies are typically based primarily on probable transport distance, but with little regard to expected travel times. This too is problematic in that tends to result in false negatives or data aliasing. Simulations from the recently developed efficient hydrologic tracer-test design methodology (EHTD) were compared with those obtained from 32 of the 33 published tracer-

  1. Development of a Novel SPECT Tracer to Image c-Met Expression in Non-Small Cell Lung Cancer in a Human Tumor Xenograft.

    PubMed

    Han, Zhaoguo; Xiao, Yadi; Wang, Kai; Yan, Ji; Xiao, Zunyu; Fang, Fang; Jin, Zhongnan; Liu, Yang; Sun, Xilin; Shen, Baozhong

    2018-05-18

    Rationale: Elevated expression of the c-Met receptor plays a crucial role in cancers. In non-small cell lung cancer (NSCLC), aberrant activation of c-Met signaling pathway contributes to tumorigenesis and cancer progression, and may mediate acquired resistance to epidermal growth factor receptor-targeted therapy. c-Met is therefore emerging as a promising therapeutic target for treating NSCLC, and the methods for noninvasive in vivo assessment of c-Met expression will improve NSCLC treatment and diagnosis. Methods: A new peptide-based (cMBP) radiotracer targeting c-Met, 99m Tc-hydrazine nicotinamide (HYNIC)-cMBP, was developed for single photon emission computed tomography (SPECT) imaging. Cell uptake assays were performed on two NSCLC cell lines with different c-Met expression: H1993 (high expression) and H1299 (no expression). In vivo tumor specificity was assessed by SPECT imaging in tumor-bearing mice at 0.5, 1, 2 and 4 h after injection of the probe. Blocking assays, biodistribution and autoradiography were also conducted to determine probe specificity. Results: 99m Tc-HYNIC-cMBP was prepared with high efficiency and showed higher uptake in H1993 cells than H1299 cells. Biodistribution and autoradiography also showed significantly higher accumulation of 99m Tc-HYNIC-cMBP in H1993 tumors than H1299 (H1993: 4.74±1.43 %ID/g and H1299: 1.00±0.37 %ID/g at 0.5h, p<0.05). H1993 tumors were clearly visualized at 0.5h in SPECT images, whereas H1299 tumors were not observed at any time. Specificity of 99m Tc-HYNIC-cMBP to c-Met was demonstrated by competitive block with excess un-radiolabeled peptide. Conclusion: We developed a novel SPECT tracer, 99m Tc-HYNIC-cMBP, for c-Met-targeted imaging in NSCLC that specifically bound to c-Met with favorable pharmacokinetics in vitro and in vivo. Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  2. TRACER - TRACING AND CONTROL OF ENGINEERING REQUIREMENTS

    NASA Technical Reports Server (NTRS)

    Turner, P. R.

    1994-01-01

    TRACER (Tracing and Control of Engineering Requirements) is a database/word processing system created to document and maintain the order of both requirements and descriptive material associated with an engineering project. A set of hierarchical documents are normally generated for a project whereby the requirements of the higher level documents levy requirements on the same level or lower level documents. Traditionally, the requirements are handled almost entirely by manual paper methods. The problem with a typical paper system, however, is that requirements written and changed continuously in different areas lead to misunderstandings and noncompliance. The purpose of TRACER is to automate the capture, tracing, reviewing, and managing of requirements for an engineering project. The engineering project still requires communications, negotiations, interactions, and iterations among people and organizations, but TRACER promotes succinct and precise identification and treatment of real requirements separate from the descriptive prose in a document. TRACER permits the documentation of an engineering project's requirements and progress in a logical, controllable, traceable manner. TRACER's attributes include the presentation of current requirements and status from any linked computer terminal and the ability to differentiate headers and descriptive material from the requirements. Related requirements can be linked and traced. The program also enables portions of documents to be printed, individual approval and release of requirements, and the tracing of requirements down into the equipment specification. Requirement "links" can be made "pending" and invisible to others until the pending link is made "binding". Individuals affected by linked requirements can be notified of significant changes with acknowledgement of the changes required. An unlimited number of documents can be created for a project and an ASCII import feature permits existing documents to be incorporated

  3. Vertical Diffusivities of Active and Passive Tracers

    NASA Technical Reports Server (NTRS)

    Canuto, V. M.; Cheng, Y.; Howard, A. M.

    2010-01-01

    The climate models that include a carbon-cycle need the vertical diffusivity of a passive tracer. Since an expression for the latter is not available, it has been common practice to identify it with that of salt. The identification is questionable since T, S are active, not passive tracers. We present the first derivation of the diffusivity of a passive tracer in terms of Ri (Richardson number) and Rq (density ratio, ratio of salinity over temperature z-gradients). The following results have emerged: (a) The passive tracer diffusivity is an algebraic function of Ri, Rq. (b) In doubly stable regimes (DS, partial derivative of T with respect to z > 0, partial derivative of S with respect to z < 0), the passive scalar diffusivity is nearly the same as that of salt/heat for any values of Rq < 0 and Ri > 0. (c) In DC regimes (diffusive convection, partial derivative of T with respect to z < 0, partial derivative of S with respect to z < 0, Rq > 1), the passive scalar diffusivity is larger than that of salt. At Ri = O(1), it can be more than twice as large. (d) In SF regimes (salt fingers, partial derivative of T with respect to z > 0, partial derivative of S with respect to z > 0, Rq < 1), the passive scalar diffusivity is smaller than that of salt. At Ri = O(1), it can be less than half of it. (e) The passive tracer diffusivity predicted at the location of NATRE (North Atlantic Tracer Release Experiment) is discussed. (f) Perhaps the most relevant conclusion is that the common identification of the tracer diffusivity with that of salt is valid only in DS regimes. In the Southern Ocean, where there is the largest CO2 absorption, the dominant regime is diffusive convection discussed in (c) above.

  4. Evaluation of 99mTc-3PRGD2 integrin receptor imaging in hepatocellular carcinoma tumour-bearing mice: comparison with 18F-FDG metabolic imaging.

    PubMed

    Zheng, Jieling; Miao, Weibing; Huang, Chao; Lin, Haoxue

    2017-07-01

    more sensitive than 18 F-FDG metabolic imaging for the detection of early stage HCC, meanwhile the tumour uptake of 99m Tc-3PRGD 2 was consistently higher than that of 18 F-FDG. However, as tumour necrosis further increased in HCC tissues, the uptake of 18 F-FDG was higher than that of 99m Tc-3PRGD 2 . Our study demonstrated that 99m Tc-3PRGD 2 is a valuable tumour molecular probe for the detection of early stage HCC compared with 18 F-FDG, meriting further investigation of 99m Tc-3PRGD 2 as a novel SPECT tracer for tumour imaging.

  5. Fractured-rock hydrogeophysics with electrically conductive and neutrally buoyant tracers

    NASA Astrophysics Data System (ADS)

    Shakas, A.; Linde, N.; Baron, L.; Le Borgne, T.; Bour, O.; Lavenant, N.; Gerard, M. F.

    2016-12-01

    Artificial tracer tests help to characterize and understand the dynamics of groundwater systems. This remains a challenging task, especially when dealing with highly heterogeneous formations in which flow can be very localized and the interpretation of tracer breakthrough curves may be ambiguous. As a complement to tracer tests, ground-penetrating radar (GPR) and electrical resistivity tomography can map the space-time migration of electrically conductive tracers. In hydrogeophysics, the most common tracer is dissolved table salt in water. However, conventional salt tracers lead to density effects that are often ignored. Even less than 1% density variations can have a dramatic effect on transport behavior and affect tracer tests in complex ways. Such effects have been demonstrated in our previous experiments that used single-hole GPR to monitor saline push-pull tests in fractured granite. It is possible to model density effects, but this leads to computational complexity and field dynamics that are not necessarily representative of the natural responses of the system. To minimize density effects, we performed a new set of push-pull tests using a neutrally buoyant and electrically conductive tracer at the same test site located close to Ploemeur, France. This novel tracer consists of a mixture of salt (NaCl), water and pure ethanol. Ethanol has a density of 789 g/L at 20° C and is used to counter-act the salt-induced density increase. Our GPR time-lapse images and tracer breakthrough data indicate a largely reversible transport process that confirms the neutral buoyancy of the tracer. Ethanol is biodegradable and does not pose significant environmental issues. Furthermore, calibration of the neutral-buoyant mixture is straightforward to perform in the field using Archimedes principle. Based on these results, we argue that neutrally buoyant ethanol-salt-water mixtures are ideal for a wide variety of hydrogeophysical tracer tests in porous or fractured media.

  6. Analysis of accumulation of 99mTc-octreotide and 99mTc-EDDA/HYNIC-Tyr3-octreotide in the rat kidneys.

    PubMed

    Kopecky, Martin; Semecky, Vladimir; Trejtnar, Frantisek; Laznicek, Milan; Laznickova, Alice; Nachtigal, Petr; Decristoforo, Clemens; Mather, Stephen J; Mäcke, Helmut R

    2004-02-01

    The aim of this study was to compare renal handling and distribution of (99m)Tc-octreotide and (99m)Tc-EDDA/HYNIC-Tyr(3)-octreotide (HYNIC-TOC) in rats. In kidney perfusion experiments, the renal clearance value of (99m)Tc-octreotide was three times lower than that of (99m)Tc-EDDA/HYNIC-TOC. The predominant renal excretion of (99m)Tc-EDDA/HYNIC-TOC was associated with a high and long-term renal accumulation up to 48 hrs. Microautoradiographic results indicated that (99m)Tc-EDDA/HYNIC-TOC was retained mainly in the renal medulla within the cells of the collecting ducts and in the surrounding tissue. Lower positivity was found in the proximal and distal tubular cells. We conclude that the mechanism of renal accumulation of somatostatin analogues renal accumulation is complex and that proximal tubular reabsorption is probably not the main mechanism for uptake of (99m)Tc-EDDA/HYNIC-TOC in the kidneys. The presence of the somatostatin receptors, differences in the tonicity level within kidneys and other possible mechanisms could participate in their renal accumulation.

  7. One year of tracer dispersion measurements over Washington, D.C.

    NASA Astrophysics Data System (ADS)

    Draxler, Roland R.

    Two perfluorocarbon tracers were released for 6 h from several locations about 20 km outside of Washington, D.C. at 36-h intervals for over 1 year. Continuous air samples were collected at 8-h intervals at one urban and two suburban sites, and at monthly intervals at 93 sites all over the region. Over 50 % of the 8-h samples showed no tracer concentration. However, about 20% of the samples had significant amounts of tracer, so that about 600 values under a variety of meteorological conditions are available for analysis. Although the Potomac River is only 100 m below the surrounding terrain, the tracer releases from within the river valley indicated that the tracer flow was channeled along the river valley. For tracer released away from the river valley, the tracer tended to pass aloft and not mix down into the river valley. Sequential concentration measurements frequently showed high values for extended periods after the tracer release terminated, decreasing exponentially with a half life of about 3 h. This suggests that the finite tracer plume may have a rather long upwind trailing edge toward the release point. The average rate of change in the vertical dispersion during summer and winter was found to be proportional to the 0.6 power of distance.

  8. Novel 99mTc(III)-azide complexes [99mTc(N3)(CDO)(CDOH)2B-R] (CDOH2=cyclohexanedione dioxime) as potential radiotracers for heart imaging.

    PubMed

    Liu, Min; Zheng, Yumin; Avcibasi, Ugur; Liu, Shuang

    2016-11-01

    In this study, novel 99m Tc(III)-azide complexes [ 99m Tc(N 3 )(CDO)(CDOH) 2 B-R] ( 99m Tc-ISboroxime-N 3 : R=IS; 99m Tc-MPboroxime-N 3 : R=MP; 99m Tc-PAboroxime-N 3 : R=PA; 99m Tc-PYboroxime-N 3 : R=PY; and 99m Tc-Uboroxime-N 3 : R=5U) were evaluated as heart imaging agents. Complexes [ 99m Tc(N 3 )(CDO)(CDOH) 2 B-R] (R=IS, MP, PA, PY and 5U) were prepared by ligand exchange between NaN 3 and [ 99m TcCl(CDO)(CDOH) 2 B-R]. Biodistribution and imaging studies were carried out in Sprague-Dawley rats. Image quantification was performed to compare their initial heart uptake and myocardial retention. 99m Tc-ISboroxime-N 3 , 99m Tc-PYboroxime-N 3 and 99m Tc-Uboroxime-N 3 were prepared with high RCP (93-98%) while the RCP of 99m Tc-MPboroxime-N 3 and 99m Tc-PAboroxime-N 3 was 80-85%. The myocardial retention curves of 99m Tc-ISboroxime-N 3 , 99m Tc-PYboroxime-N 3 and 99m Tc-Uboroxime-N 3 were best fitted to the bi-exponential decay function. The half-time of the fast component was 1.6±0.4min for 99m Tc-ISboroxime-N 3 , 0.7±0.1min for 99m Tc-PYboroxime-N 3 and 0.9±0.4min for 99m Tc-Uboroxime-N 3 . The 2-min heart uptake from biodistribution studies followed the ranking order of 99m Tc-ISboroxime-N 3 (3.60±0.68%ID/g)> 99m Tc-PYboroxime-N 3 (2.35±0.37%ID/g)≫ 99m Tc-Uboroxime-N 3 (1.29±0.06%ID/g). 99m Tc-ISboroxime-N 3 had the highest 2-min heart uptake among 99m Tc radiotracers revaluated in SD rats. High quality SPECT images were obtained with the right and left ventricular walls being clearly delineated. The best image acquisition window was 0-5min for 99m Tc-ISboroxime-N 3 . Both azide coligand and boronate caps had significant impact on the heart uptake and myocardial retention of complexes [ 99m Tc(N 3 )(CDO)(CDOH) 2 B-R]. Among the radiotracers evaluated in SD rats, 99m Tc-ISboroxime-N 3 has the highest initial heart uptake with the heart retention comparable to that of 99m Tc-Teboroxime. 99m Tc-ISboroxime-N 3 is a promising alternative to 99m Tc-Teboroxime for

  9. Combined Optical Coherence and Fluorescence Microscopy to assess dynamics and specificity of pancreatic beta-cell tracers

    PubMed Central

    Berclaz, Corinne; Pache, Christophe; Bouwens, Arno; Szlag, Daniel; Lopez, Antonio; Joosten, Lieke; Ekim, Selen; Brom, Maarten; Gotthardt, Martin; Grapin-Botton, Anne; Lasser, Theo

    2015-01-01

    The identification of a beta-cell tracer is a major quest in diabetes research. However, since MRI, PET and SPECT cannot resolve individual islets, optical techniques are required to assess the specificity of these tracers. We propose to combine Optical Coherence Microscopy (OCM) with fluorescence detection in a single optical platform to facilitate these initial screening steps from cell culture up to living rodents. OCM can image islets and vascularization without any labeling. Thereby, it alleviates the need of both genetically modified mice to detect islets and injection of external dye to reveal vascularization. We characterized Cy5.5-exendin-3, an agonist of glucagon-like peptide 1 receptor (GLP1R), for which other imaging modalities have been used and can serve as a reference. Cultured cells transfected with GLP1R and incubated with Cy5.5-exendin-3 show full tracer internalization. We determined that a dose of 1 μg of Cy5.5-exendin-3 is sufficient to optically detect in vivo the tracer in islets with a high specificity. In a next step, time-lapse OCM imaging was used to monitor the rapid and specific tracer accumulation in murine islets and its persistence over hours. This optical platform represents a versatile toolbox for selecting beta-cell specific markers for diabetes research and future clinical diagnosis. PMID:25988507

  10. Combining Empirical Relationships with Data Based Mechanistic Modeling to Inform Solute Tracer Investigations across Stream Orders

    NASA Astrophysics Data System (ADS)

    Herrington, C.; Gonzalez-Pinzon, R.; Covino, T. P.; Mortensen, J.

    2015-12-01

    Solute transport studies in streams and rivers often begin with the introduction of conservative and reactive tracers into the water column. Information on the transport of these substances is then captured within tracer breakthrough curves (BTCs) and used to estimate, for instance, travel times and dissolved nutrient and carbon dynamics. Traditionally, these investigations have been limited to systems with small discharges (< 200 L/s) and with small reach lengths (< 500 m), partly due to the need for a priori information of the reach's hydraulic characteristics (e.g., channel geometry, resistance and dispersion coefficients) to predict arrival times, times to peak concentrations of the solute and mean travel times. Current techniques to acquire these channel characteristics through preliminary tracer injections become cost prohibitive at higher stream orders and the use of semi-continuous water quality sensors for collecting real-time information may be affected from erroneous readings that are masked by high turbidity (e.g., nitrate signals with SUNA instruments or fluorescence measures) and/or high total dissolved solids (e.g., making prohibitively expensive the use of salt tracers such as NaCl) in larger systems. Additionally, a successful time-of-travel study is valuable for only a single discharge and river stage. We have developed a method to predict tracer BTCs to inform sampling frequencies at small and large stream orders using empirical relationships developed from multiple tracer injections spanning several orders of magnitude in discharge and reach length. This method was successfully tested in 1st to 8th order systems along the Middle Rio Grande River Basin in New Mexico, USA.

  11. 3-D numerical evaluation of density effects on tracer tests.

    PubMed

    Beinhorn, M; Dietrich, P; Kolditz, O

    2005-12-01

    In this paper we present numerical simulations carried out to assess the importance of density-dependent flow on tracer plume development. The scenario considered in the study is characterized by a short-term tracer injection phase into a fully penetrating well and a natural hydraulic gradient. The scenario is thought to be typical for tracer tests conducted in the field. Using a reference case as a starting point, different model parameters were changed in order to determine their importance to density effects. The study is based on a three-dimensional model domain. Results were interpreted using concentration contours and a first moment analysis. Tracer injections of 0.036 kg per meter of saturated aquifer thickness do not cause significant density effects assuming hydraulic gradients of at least 0.1%. Higher tracer input masses, as used for geoelectrical investigations, may lead to buoyancy-induced flow in the early phase of a tracer test which in turn impacts further plume development. This also holds true for shallow aquifers. Results of simulations with different tracer injection rates and durations imply that the tracer input scenario has a negligible effect on density flow. Employing model cases with different realizations of a log conductivity random field, it could be shown that small variations of hydraulic conductivity in the vicinity of the tracer injection well have a major control on the local tracer distribution but do not mask effects of buoyancy-induced flow.

  12. Clinical usefulness of 99mTc-EDDA/HYNIC-TOC scintigraphy in oncological diagnostics: a pilot study.

    PubMed

    Plachcinska, Anna; Mikolajczak, Renata; Maecke, Helmut; Mlodkowska, Ewa; Kunert-Radek, Jolanta; Michalski, Andrzej; Rzeszutek, Katarzyna; Kozak, Jozek; Kusmierek, Jacek

    2004-04-01

    The clinical usefulness of a new 99mTc-labeled somatostatin analogue has been studied from the standpoint of oncological diagnostics. The group of patients studied included 40 individuals with diagnosed malignant neoplasms (32 primary and 8 metastatic). Among the primary tumors were 7 pituitary adenomas (5 hormonally active and 2 inactive), 1 liposarcoma, 2 carcinoids, 1 breast carcinoma, and 21 cases of lung cancer (2 small cell and 19 non-small cell) were represented. The metastatic tumors consisted of: 3 malignant melanomas, 1 pheochromocytoma, 1 prostatic cancer, 1 leiomyosarcoma, 1 pancreatic carcinoma ectopically secreting ACTH, and 1 carcinoid of the thymus. The radiopharmaceutical, 99mTc-EDDA/HYNIC-octreotide, was i.v. administered at the activity of 740-925 MBq. The imaging was comprized of a whole-body scan and single photon emission computed tomography. Positive scintigrams were obtained in 4 of 5 hormonally active pituitary adenomas, in 1 of 2 cases of carcinoid, in liposarcoma, breast cancer, and all cases of small cell (SCLC) and non-small cell lung cancer (NSCLC). The neoplastic metastases were visualized in 2 of 3 cases of melanoma and in patients with pheochromocytoma, pancreatic carcinoma secreting ACTH, and thymic carcinoid. Scintigrams were negative in both hormonally inactive pituitary adenomas, in one case of metastatic malignant melanoma, leiomyosarcoma, and in cases of metastasis from the prostatic carcinomas. The results of this pilot study indicated that 99mTc-EDDA/HYNIC-TOC is a potentially useful radiopharmaceutical for the imaging of a wide range of primary and metastatic tumors. More detailed indications for the clinical usefulness of the new tracer for the imaging of selected tumor types require studies on much larger groups of patients. Special attention should be paid to the successful imaging of all cases of NSCLC.

  13. Tracking groundwater discharge to a large river using tracers and geophysics.

    PubMed

    Harrington, Glenn A; Gardner, W Payton; Munday, Tim J

    2014-01-01

    Few studies have investigated large reaches of rivers in which multiple sources of groundwater are responsible for maintaining baseflow. This paper builds upon previous work undertaken along the Fitzroy River, one of the largest perennial river systems in north-western Australia. Synoptic regional-scale sampling of both river water and groundwater for a suite of environmental tracers ((4) He, (87) Sr/(86) Sr, (222) Rn and major ions), and subsequent modeling of tracer behavior in the river, has enabled definition and quantification of groundwater input from at least three different sources. We show unambiguous evidence of both shallow "local" groundwater, possibly recharged to alluvial aquifers beneath the adjacent floodplain during recent high-flow events, and old "regional" groundwater introduced via artesian flow from deep confined aquifers. We also invoke hyporheic exchange and either bank return flow or parafluvial flow to account for background (222) Rn activities and anomalous chloride trends along river reaches where there is no evidence of the local or regional groundwater inputs. Vertical conductivity sections acquired through an airborne electromagnetic (AEM) survey provide insights to the architecture of the aquifers associated with these sources and general groundwater quality characteristics. These data indicate fresh groundwater from about 300 m below ground preferentially discharging to the river, at locations consistent with those inferred from tracer data. The results demonstrate how sampling rivers for multiple environmental tracers of different types-including stable and radioactive isotopes, dissolved gases and major ions-can significantly improve conceptualization of groundwater-surface water interaction processes, particularly when coupled with geophysical techniques in complex hydrogeological settings. © 2013, National Ground Water Association.

  14. 99mTc-stannous colloid white cell scintigraphy in childhood inflammatory bowel disease.

    PubMed

    Peacock, Kenneth; Porn, Ute; Howman-Giles, Robert; O'Loughlin, Edward; Uren, Roger; Gaskin, Kevin; Dorney, Stuart; Kamath, Ramanand

    2004-02-01

    99mTc-Labeled white cell scintigraphy (WCS) has been used for the investigation of inflammatory bowel disease (IBD) in adults, but data on children are limited. The most common agent used is (99m) Tc-hexamethylpropyleneamine oxime (HMPAO); however, this agent has limitations. In a retrospective study, we assessed the use of (99m)Tc-stannous colloid WCS for the initial evaluation of children with suspected IBD. Diagnostic, endoscopic, and contrast radiography results were retrospectively collected from the medical records. Two experienced nuclear physicians unaware of the patient data interpreted the WCS results, with agreement reached by consensus. Statistical analysis was performed on the ability of WCS to detect active disease and localize it topographically and on a comparison of diagnostic methods, using a combination of clinical features and endoscopy as the reference standard. Between 1996 and 1999, 64 patients (35 male and 29 female; mean age, 12.5 y; age range, 2-19 y) had WCS performed, with IBD subsequently diagnosed in 34 patients. (99m)Tc-Stannous colloid WCS had an 88% sensitivity, 90% specificity, and 8.8 likelihood ratio for initial investigation of IBD. Agreement was poor for topographic localization of disease. Small-bowel series had a 75% sensitivity, 50% specificity, and 1.5 likelihood ratio for detecting endoscopic disease of the terminal ileum and proximal colon. Our results confirm that WCS is a useful imaging technique for the initial evaluation of patients with suspected IBD. (99m)Tc-Stannous colloid had results at least comparable to those of other WCS agents, and in children, (99m)Tc-stannous colloid WCS should be preferred in view of lower cost, shorter preparation time, and the smaller blood volumes required.

  15. Comparison of different tracers for PIV measurements in EHD airflow

    NASA Astrophysics Data System (ADS)

    Hamdi, M.; Havet, M.; Rouaud, O.; Tarlet, D.

    2014-04-01

    In this study, a proposed method for selecting a tracer for particle imaging velocimetry (PIV) measurement in electrohydrodynamics flows was developed. To begin with, several published studies were identified that exploit different tracers, such as oil smoke, cigarette smoke and titanium dioxide (TiO2). An assortment of tracers was then selected based on comparisons with conventional dimensionless numbers; Stokes number ( St), Archimedes number ( Ar) and electrical mobility ratio ( M). Subsequently, an experimental study for testing tracers was developed, which enabled the velocity profile of an ionic wind generated by a needle/ring configuration to be measured. Air velocity measurements carried out with a Pitot tube, considered as the reference measurements, were compared to PIV measurements for each tracer. In addition, the current-voltage curves and the evolution of the current during seeding were measured. All the experimental results show that TiO2, SiO2 microballoons and incense smoke are the ideal tracers in the series of tracers investigated.

  16. The Tribolium chitin synthase genes TcCHS1 and TcCHS2 are specialized for synthesis of epidermal cuticle and midgut peritrophic matrix.

    PubMed

    Arakane, Y; Muthukrishnan, S; Kramer, K J; Specht, C A; Tomoyasu, Y; Lorenzen, M D; Kanost, M; Beeman, R W

    2005-10-01

    Functional analysis of the two chitin synthase genes, TcCHS1 and TcCHS2, in the red flour beetle, Tribolium castaneum, revealed unique and complementary roles for each gene. TcCHS1-specific RNA interference (RNAi) disrupted all three types of moult (larval-larval, larval-pupal and pupal-adult) and greatly reduced whole-body chitin content. Exon-specific RNAi showed that splice variant 8a of TcCHS1 was required for both the larval-pupal and pupal-adult moults, whereas splice variant 8b was required only for the latter. TcCHS2-specific RNAi had no effect on metamorphosis or on total body chitin content. However, RNAi-mediated down-regulation of TcCHS2, but not TcCHS1, led to cessation of feeding, a dramatic shrinkage in larval size and reduced chitin content in the midgut.

  17. Determination of water saturation using gas phase partitioning tracers and time-lapse electrical conductivity measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Timothy C.; Oostrom, Martinus; Truex, Michael J.

    2013-05-21

    Water saturation is an important indicator of contaminant distribution and plays a governing role in contaminant transport within the vadose zone. Understanding the water saturation distribution is critical for both remediation and contaminant flux monitoring in unsaturated environments. In this work we propose and demonstrate a method of remotely determining water saturation levels using gas phase partitioning tracers and time-lapse bulk electrical conductivity measurements. The theoretical development includes the partitioning chemistry for the tracers we demonstrate (ammonia and carbon dioxide), as well as a review of the petrophysical relationship governing how these tracers influence bulk conductivity. We also investigate methodsmore » of utilizing secondary information provided by electrical conductivity breakthrough magnitudes induced by the tracers. We test the method on clean, well characterized, intermediate-scale sand columns under controlled conditions. Results demonstrate the capability to predict partitioning coefficients and accurately monitor gas breakthrough curves along the length of the column according to the corresponding electrical conductivity response, leading to accurate water saturation estimates. This work is motivated by the need to develop effective characterization and monitoring techniques for contaminated deep vadose zone environments, and provides a proof-of-concept toward uniquely characterizing and monitoring water saturation levels at the field scale and in three-dimensions using electrical resistivity tomography.« less

  18. Assessment of the direct cyclotron production of (99m)Tc: An approach to crisis management of (99m)Tc shortage.

    PubMed

    Rovais, Mohammad Reza Aboudzadeh; Aardaneh, Khosro; Aslani, Gholamreza; Rahiminejad, Ali; Yousefi, Kamran; Boulouri, Fatemeh

    2016-06-01

    Nowadays, the cyclotron production of technetium-99m ((99m)Tc) has been increased, due to the worldwide (99m)Tc generator shortage. In the present work, an improved strategy for the production of (99m)Tc, using the proton irradiation of the enriched (100)Mo was developed. The performance of this method in terms of the production yield, chemical purity, radiochemical purity, as well as radionuclide purity was evaluated. The average production yield was measured to be 356MBqμA(-1)h(-1). A good agreement was found between the calculated production yield and the experimental one. The radiochemical separation and total recovery yields of (99m)Tc were 92% and 69%, respectively. The radiochemical and the radionuclide purities of the (99m)Tc were 99% and >99.99% at the end of purification, respectively. The results of quality control tests (QC) support the concept that cyclotron-produced (99m)Tc is suitable for preparation of USP-compliant. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. A field comparison of multiple techniques to quantify groundwater - surface-water interactions

    USGS Publications Warehouse

    González-Pinzón, Ricardo; Ward, Adam S; Hatch, Christine E; Wlostowski, Adam N; Singha, Kamini; Gooseff, Michael N.; Haggerty, Roy; Harvey, Judson; Cirpka, Olaf A; Brock, James T

    2015-01-01

    Groundwater–surface-water (GW-SW) interactions in streams are difficult to quantify because of heterogeneity in hydraulic and reactive processes across a range of spatial and temporal scales. The challenge of quantifying these interactions has led to the development of several techniques, from centimeter-scale probes to whole-system tracers, including chemical, thermal, and electrical methods. We co-applied conservative and smart reactive solute-tracer tests, measurement of hydraulic heads, distributed temperature sensing, vertical profiles of solute tracer and temperature in the stream bed, and electrical resistivity imaging in a 450-m reach of a 3rd-order stream. GW-SW interactions were not spatially expansive, but were high in flux through a shallow hyporheic zone surrounding the reach. NaCl and resazurin tracers suggested different surface–subsurface exchange patterns in the upper ⅔ and lower ⅓ of the reach. Subsurface sampling of tracers and vertical thermal profiles quantified relatively high fluxes through a 10- to 20-cm deep hyporheic zone with chemical reactivity of the resazurin tracer indicated at 3-, 6-, and 9-cm sampling depths. Monitoring of hydraulic gradients along transects with MINIPOINT streambed samplers starting ∼40 m from the stream indicated that groundwater discharge prevented development of a larger hyporheic zone, which progressively decreased from the stream thalweg toward the banks. Distributed temperature sensing did not detect extensive inflow of ground water to the stream, and electrical resistivity imaging showed limited large-scale hyporheic exchange. We recommend choosing technique(s) based on: 1) clear definition of the questions to be addressed (physical, biological, or chemical processes), 2) explicit identification of the spatial and temporal scales to be covered and those required to provide an appropriate context for interpretation, and 3) maximizing generation of mechanistic understanding and reducing costs of

  20. Convective and Wave Signatures in Ozone Profiles Over the Equatorial Americas: Views from TC4 (2007) and SHADOZ

    NASA Technical Reports Server (NTRS)

    Thompson, Anne M.; MacFarlane, Alaina M.; Morris, Gary A.; Yorks, John E.; Miller, Sonya K.; Taubman, Brett F.; Verver, Ge; Voemel, Holger; Avery, Melody A.; Hair, Johnathan W.; hide

    2009-01-01

    During the months of July-August 2007 NASA conducted a research campaign called the Tropical Composition, Clouds and Climate Coupling (TC4) experiment. Vertical profiles of ozone were measured daily using an instrument known as an ozonesonde, which is attached to a weather balloon and launch to altitudes in excess of 30 km. These ozone profiles were measured over coastal Las Tablas, Panama (7.8N, 80W) and several times per week at Alajuela, Costa Rica (ION, 84W). Meteorological systems in the form of waves, detected most prominently in 100- 300 in thick ozone layer in the tropical tropopause layer, occurred in 50% (Las Tablas) and 40% (Alajuela) of the soundings. These layers, associated with vertical displacements and classified as gravity waves ("GW," possibly Kelvin waves), occur with similar stricture and frequency over the Paramaribo (5.8N, 55W) and San Cristobal (0.925, 90W) sites of the Southern Hemisphere Additional Ozonesondes (SHADOZ) network. The gravity wave labeled layers in individual soundings correspond to cloud outflow as indicated by the tracers measured from the NASA DC-8 and other aircraft data, confirming convective initiation of equatorial waves. Layers representing quasi-horizontal displacements, referred to as Rossby waves, are robust features in soundings from 23 July to 5 August. The features associated with Rossby waves correspond to extra-tropical influence, possibly stratospheric, and sometimes to pollution transport. Comparison of Las Tablas and Alajuela ozone budgets with 1999-2007 Paramaribo and San Cristobal soundings shows that TC4 is typical of climatology for the equatorial Americas. Overall during TC4, convection and associated meteorological waves appear to dominate ozone transport in the tropical tropopause layer.

  1. Stratospheric temperatures and tracer transport in a nudged 4-year middle atmosphere GCM simulation

    NASA Astrophysics Data System (ADS)

    van Aalst, M. K.; Lelieveld, J.; Steil, B.; Brühl, C.; Jöckel, P.; Giorgetta, M. A.; Roelofs, G.-J.

    2005-02-01

    We have performed a 4-year simulation with the Middle Atmosphere General Circulation Model MAECHAM5/MESSy, while slightly nudging the model's meteorology in the free troposphere (below 113 hPa) towards ECMWF analyses. We show that the nudging 5 technique, which leaves the middle atmosphere almost entirely free, enables comparisons with synoptic observations. The model successfully reproduces many specific features of the interannual variability, including details of the Antarctic vortex structure. In the Arctic, the model captures general features of the interannual variability, but falls short in reproducing the timing of sudden stratospheric warmings. A 10 detailed comparison of the nudged model simulations with ECMWF data shows that the model simulates realistic stratospheric temperature distributions and variabilities, including the temperature minima in the Antarctic vortex. Some small (a few K) model biases were also identified, including a summer cold bias at both poles, and a general cold bias in the lower stratosphere, most pronounced in midlatitudes. A comparison 15 of tracer distributions with HALOE observations shows that the model successfully reproduces specific aspects of the instantaneous circulation. The main tracer transport deficiencies occur in the polar lowermost stratosphere. These are related to the tropopause altitude as well as the tracer advection scheme and model resolution. The additional nudging of equatorial zonal winds, forcing the quasi-biennial oscillation, sig20 nificantly improves stratospheric temperatures and tracer distributions.

  2. Characterization of an alluvial aquifer with thermal tracer tomography

    NASA Astrophysics Data System (ADS)

    Somogyvári, Márk; Bayer, Peter

    2017-04-01

    In the summer of 2015, a series of thermal tracer tests was performed at the Widen field site in northeast Switzerland. At this site numerous hydraulic, tracer, geophysical and hydrogeophysical field tests have been conducted in the past to investigate a shallow alluvial aquifer. The goals of the campaign in 2015 were to design a cost-effective thermal tracer tomography setup and to validate the concept of travel time-based thermal tracer tomography under field conditions. Thermal tracer tomography uses repeated thermal tracer injections with different injection depths and distributed temperature measurements to map the hydraulic conductivity distribution of a heterogeneous aquifer. The tracer application was designed with minimal experimental time and cost. Water was heated in inflatable swimming pools using direct sunlight of the warm summer days, and it was injected as low temperature pulses in a well. Because of the small amount of injected heat, no long recovery times were required between the repeated heat tracer injections and every test started from natural thermal conditions. At Widen, four thermal tracer tests were performed during a period of three days. Temperatures were measured in one downgradient well using a distributed temperature measurement system installed at seven depth points. Totally 12 temperature breakthrough curves were collected. Travel time based tomographic inversion assumes that thermal transport is dominated by advection and the travel time of the thermal tracer can be related to the hydraulic conductivities of the aquifer. This assumption is valid in many shallow porous aquifers where the groundwater flow is fast. In our application, the travel time problem was treated by a tomographic solver, analogous to seismic tomography, to derive the hydraulic conductivity distribution. At the test site, a two-dimensional cross-well hydraulic conductivity profile was reconstructed with the travel time based inversion. The reconstructed profile

  3. Determination of the Isotopic Enrichment of 13C- and 2H-Labeled Tracers of Glucose Using High-Resolution Mass Spectrometry: Application to Dual- and Triple-Tracer Studies.

    PubMed

    Trötzmüller, Martin; Triebl, Alexander; Ajsic, Amra; Hartler, Jürgen; Köfeler, Harald; Regittnig, Werner

    2017-11-21

    Multiple-tracer approaches for investigating glucose metabolism in humans usually involve the administration of stable and radioactive glucose tracers and the subsequent determination of tracer enrichments in sampled blood. When using conventional, low-resolution mass spectrometry (LRMS), the number of spectral interferences rises rapidly with the number of stable tracers employed. Thus, in LRMS, both computational effort and statistical uncertainties associated with the correction for spectral interferences limit the number of stable tracers that can be simultaneously employed (usually two). Here we show that these limitations can be overcome by applying high-resolution mass spectrometry (HRMS). The HRMS method presented is based on the use of an Orbitrap mass spectrometer operated at a mass resolution of 100 000 to allow electrospray-generated ions of the deprotonated glucose molecules to be monitored at their exact masses. The tracer enrichment determination in blood plasma is demonstrated for several triple combinations of 13 C- and 2 H-labeled glucose tracers (e.g., [1- 2 H 1 ]-, [6,6- 2 H 2 ]-, [1,6- 13 C 2 ]glucose). For each combination it is shown that ions arising from 2 H-labeled tracers are completely differentiated from those arising from 13 C-labeled tracers, thereby allowing the enrichment of a tracer to be simply calculated from the observed ion intensities using a standard curve with curve parameters unaffected by the presence of other tracers. For each tracer, the HRMS method exhibits low limits of detection and good repeatability in the tested 0.1-15.0% enrichment range. Additionally, due to short sample preparation and analysis times, the method is well-suited for high-throughput determination of multiple glucose tracer enrichments in plasma samples.

  4. Discordant hepatic uptake between Tc-99m sulfur colloid and Tc-99m DISIDA in hypervitaminosis A

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vincent, L.M.; McCartney, W.H.; Mauro, M.A.

    1984-02-01

    Scintigraphic findings in a patient with biopsy-proven hypervitaminosis A included markedly impaired hepatic uptake of Tc-99m sulfur colloid but essentially normal uptake of Tc-99m DISIDA. This case presents a potential cause for image discordance with these two agents.

  5. 10 CFR 39.45 - Subsurface tracer studies.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Subsurface tracer studies. 39.45 Section 39.45 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR WELL LOGGING Equipment § 39.45 Subsurface tracer studies. (a) The licensee shall require all personnel handling radioactive...

  6. 10 CFR 39.45 - Subsurface tracer studies.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Subsurface tracer studies. 39.45 Section 39.45 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR WELL LOGGING Equipment § 39.45 Subsurface tracer studies. (a) The licensee shall require all personnel handling radioactive...

  7. Using Neural Networks to Describe Tracer Correlations

    NASA Technical Reports Server (NTRS)

    Lary, D. J.; Mueller, M. D.; Mussa, H. Y.

    2003-01-01

    Neural networks are ideally suited to describe the spatial and temporal dependence of tracer-tracer correlations. The neural network performs well even in regions where the correlations are less compact and normally a family of correlation curves would be required. For example, the CH4-N2O correlation can be well described using a neural network trained with the latitude, pressure, time of year, and CH4 volume mixing ratio (v.m.r.). In this study a neural network using Quickprop learning and one hidden layer with eight nodes was able to reproduce the CH4-N2O correlation with a correlation co- efficient of 0.9995. Such an accurate representation of tracer-tracer correlations allows more use to be made of long-term datasets to constrain chemical models. Such as the dataset from the Halogen Occultation Experiment (HALOE) which has continuously observed CH4, (but not N2O) from 1991 till the present. The neural network Fortran code used is available for download.

  8. Impeding 99Tc(IV) mobility in novel waste forms

    PubMed Central

    Lee, Mal-Soon; Um, Wooyong; Wang, Guohui; Kruger, Albert A.; Lukens, Wayne W.; Rousseau, Roger; Glezakou, Vassiliki-Alexandra

    2016-01-01

    Technetium (99Tc) is an abundant, long-lived radioactive fission product whose mobility in the subsurface is largely governed by its oxidation state. Tc immobilization is crucial for radioactive waste management and environmental remediation. Tc(IV) incorporation in spinels has been proposed as a novel method to increase Tc retention in glass waste forms during vitrification. However, experiments under high-temperature and oxic conditions show reoxidation of Tc(IV) to volatile pertechnetate, Tc(VII). Here we examine this problem with ab initio molecular dynamics simulations and propose that, at elevated temperatures, doping with first row transition metal can significantly enhance Tc retention in magnetite in the order Co>Zn>Ni. Experiments with doped spinels at 700 °C provide quantitative confirmation of the theoretical predictions in the same order. This work highlights the power of modern, state-of-the-art simulations to provide essential insights and generate theory-inspired design criteria of complex materials at elevated temperatures. PMID:27357121

  9. Tc depression and superconductor-insulator transition in molybdenum nitride thin films

    NASA Astrophysics Data System (ADS)

    Ichikawa, F.; Makise, K.; Tsuneoka, T.; Maeda, S.; Shinozaki, B.

    2018-03-01

    We have studied that the Tc depression and the superconductor-insulator transition (SIT) in molybdenum nitride (MoN) thin films. Thin films were fabricated by reactive DC magnetron sputtering method onto (100) MgO substrates in the mixture of Ar and N2 gases. Several dozen MoN thin films were prepared in the range of 3 nm < thickness d < 60 nm. The resistance was measured by a DC four-probe technique. It is found that Tc decreases from 6.6 K for thick films with increase of the normal state sheet resistance {R}{{sq}}{{N}} and experimental data were fitted to the Finkel’stein formula using the bulk superconducting transition temperature Tc 0 = 6.45 K and the elastic scattering time of electron τ = 1.6 × 10‑16 s. From this analysis the critical sheet resistance Rc is found about 2 kΩ, which is smaller than the quantum sheet resistance R Q. This value of Rc is almost the same as those for 2D NbN films. The value of τ for MoN films is also the similar value for NbN films 1.0 × 10‑16 s, while Tc 0 is different from that for NbN films 14.85 K. It is indicated that the mechanism of SIT for MoN films is similar to that of NbN films, while the mean free path ℓ for MoN films is larger than that for NbN films.

  10. A novel standardized algorithm using SPECT/CT evaluating unhappy patients after unicondylar knee arthroplasty--a combined analysis of tracer uptake distribution and component position.

    PubMed

    Suter, Basil; Testa, Enrique; Stämpfli, Patrick; Konala, Praveen; Rasch, Helmut; Friederich, Niklaus F; Hirschmann, Michael T

    2015-03-20

    The introduction of a standardized SPECT/CT algorithm including a localization scheme, which allows accurate identification of specific patterns and thresholds of SPECT/CT tracer uptake, could lead to a better understanding of the bone remodeling and specific failure modes of unicondylar knee arthroplasty (UKA). The purpose of the present study was to introduce a novel standardized SPECT/CT algorithm for patients after UKA and evaluate its clinical applicability, usefulness and inter- and intra-observer reliability. Tc-HDP-SPECT/CT images of consecutive patients (median age 65, range 48-84 years) with 21 knees after UKA were prospectively evaluated. The tracer activity on SPECT/CT was localized using a specific standardized UKA localization scheme. For tracer uptake analysis (intensity and anatomical distribution pattern) a 3D volumetric quantification method was used. The maximum intensity values were recorded for each anatomical area. In addition, ratios between the respective value in the measured area and the background tracer activity were calculated. The femoral and tibial component position (varus-valgus, flexion-extension, internal and external rotation) was determined in 3D-CT. The inter- and intraobserver reliability of the localization scheme, grading of the tracer activity and component measurements were determined by calculating the intraclass correlation coefficients (ICC). The localization scheme, grading of the tracer activity and component measurements showed high inter- and intra-observer reliabilities for all regions (tibia, femur and patella). For measurement of component position there was strong agreement between the readings of the two observers; the ICC for the orientation of the femoral component was 0.73-1.00 (intra-observer reliability) and 0.91-1.00 (inter-observer reliability). The ICC for the orientation of the tibial component was 0.75-1.00 (intra-observer reliability) and 0.77-1.00 (inter-observer reliability). The SPECT/CT algorithm

  11. Characterizing coarse bedload transport during floods with RFID and accelerometer tracers, in-stream RFID antennas and HEC-RAS modeling

    NASA Astrophysics Data System (ADS)

    Olinde, L.; Johnson, J. P.

    2013-12-01

    snowmelt hydrograph are modeled over the 11 kilometers of surveyed stream by utilizing 1m airborne LiDAR and HEC-GeoRAS. Cross-sectional HEC-RAS results are used to estimate the spatial distribution of longitudinal shear velocities over the observed discharges. At final accelerometer tracer positions, we analyze the HEC-RAS generated flow conditions for each disentrainment discharge magnitude. The techniques developed here have the potential to link individual grain characteristics during floods to a range of time and length scales.

  12. Development of a Luminex Bead Based Assay for Diagnosis of Toxocariasis Using Recombinant Antigens Tc-CTL-1 and Tc-TES-26.

    PubMed

    Anderson, John P; Rascoe, Lisa N; Levert, Keith; Chastain, Holly M; Reed, Matthew S; Rivera, Hilda N; McAuliffe, Isabel; Zhan, Bin; Wiegand, Ryan E; Hotez, Peter J; Wilkins, Patricia P; Pohl, Jan; Handali, Sukwan

    2015-01-01

    The clinical spectrum of human disease caused by the roundworms Toxocara canis and Toxocara cati ranges from visceral and ocular larva migrans to covert toxocariasis. The parasite is not typically recovered in affected tissues, so detection of parasite-specific antibodies is usually necessary for establishing a diagnosis. The most reliable immunodiagnostic methods use the Toxocara excretory-secretory antigens (TES-Ag) in ELISA formats to detect Toxocara-specific antibodies. To eliminate the need for native parasite materials, we identified and purified immunodiagnostic antigens using 2D gel electrophoresis followed by electrospray ionization mass spectrometry. Three predominant immunoreactive proteins were found in the TES; all three had been previously described in the literature: Tc-CTL-1, Tc-TES-26, and Tc-MUC-3. We generated Escherichia coli expressed recombinant proteins for evaluation in Luminex based immunoassays. We were unable to produce a functional assay with the Tc-MUC-3 recombinant protein. Tc-CTL-1 and Tc-TES-26 were successfully coupled and tested using defined serum batteries. The use of both proteins together generated better results than if the proteins were used individually. The sensitivity and specificity of the assay for detecting visceral larval migrans using Tc-CTL-1 plus Tc-TES-26 was 99% and 94%, respectively; the sensitivity for detecting ocular larval migrans was 64%. The combined performance of the new assay was superior to the currently available EIA and could potentially be employed to replace current assays that rely on native TES-Ag.

  13. Development of a Luminex Bead Based Assay for Diagnosis of Toxocariasis Using Recombinant Antigens Tc-CTL-1 and Tc-TES-26

    PubMed Central

    Anderson, John P.; Rascoe, Lisa N.; Levert, Keith; Chastain, Holly M.; Reed, Matthew S.; Rivera, Hilda N.; McAuliffe, Isabel; Zhan, Bin; Wiegand, Ryan E.; Hotez, Peter J.; Wilkins, Patricia P.; Pohl, Jan; Handali, Sukwan

    2015-01-01

    The clinical spectrum of human disease caused by the roundworms Toxocara canis and Toxocara cati ranges from visceral and ocular larva migrans to covert toxocariasis. The parasite is not typically recovered in affected tissues, so detection of parasite-specific antibodies is usually necessary for establishing a diagnosis. The most reliable immunodiagnostic methods use the Toxocara excretory-secretory antigens (TES-Ag) in ELISA formats to detect Toxocara-specific antibodies. To eliminate the need for native parasite materials, we identified and purified immunodiagnostic antigens using 2D gel electrophoresis followed by electrospray ionization mass spectrometry. Three predominant immunoreactive proteins were found in the TES; all three had been previously described in the literature: Tc-CTL-1, Tc-TES-26, and Tc-MUC-3. We generated Escherichia coli expressed recombinant proteins for evaluation in Luminex based immunoassays. We were unable to produce a functional assay with the Tc-MUC-3 recombinant protein. Tc-CTL-1 and Tc-TES-26 were successfully coupled and tested using defined serum batteries. The use of both proteins together generated better results than if the proteins were used individually. The sensitivity and specificity of the assay for detecting visceral larval migrans using Tc-CTL-1 plus Tc-TES-26 was 99% and 94%, respectively; the sensitivity for detecting ocular larval migrans was 64%. The combined performance of the new assay was superior to the currently available EIA and could potentially be employed to replace current assays that rely on native TES-Ag. PMID:26485145

  14. Clinical significance of TC21 overexpression in oral cancer.

    PubMed

    Macha, Muzafar A; Matta, Ajay; Sriram, Uma; Thakkar, Alok; Shukla, N K; Datta Gupta, Siddhartha; Ralhan, Ranju

    2010-07-01

    In search of novel molecular markers for oral cancer, we reported increased levels of TC21/R-Ras2 transcripts in oral squamous cell carcinoma by differential display. The aim of this study was to determine the clinical significance of TC21 in oral cancer. Immunohistochemical analysis of TC21 protein expression was carried out in 120 leukoplakias, 83 OSCCs and 30 non-malignant tissues, confirmed by immunoblotting, and correlated with clinicopathological parameters as well as disease prognosis. Co-immunoprecipitation assays were carried out to identify the interaction partners of TC21 protein in oral cancer cells and tissues. TC21 nuclear expression increased from normal oral tissues to leukoplakia and frank malignancy (P < 0.001). TC21 overexpression was observed in 74.2% leukoplakia with no dysplasia, 75.9% dysplasias and 79.5% OSCCs in comparison with normal oral tissues. Receiver operating characteristic analysis showed that the area-under-the curve values were 0.895, 0.885, and 0.919, while the positive predictive values were 95.8%, 95.6%, and 97.1%, for nuclear immunostaining for normal versus leukoplakia with no dysplasia, leukoplakic lesions with dysplasia, and OSCCs, respectively. Immunoblotting confirmed overexpression of TC21 in oral lesions. Using co-immunoprecipitation assays, we showed interactions of TC21 with Erk2, PI3-K, 14-3-3zeta and 14-3-3sigma proteins in oral cancer cells. Our findings suggested that alteration in TC21 expression is an early event in oral cancer and correlates with poor prognosis of OSCCs. TC21 interactions with Erk2, PI3-K, 14-3-3zeta and 14-3-3sigma proteins in oral cancer cells and tissues suggests the involvement of TC21 in signaling pathways in oral cancer.

  15. Tuning structure and mobility of solvation shells surrounding tracer additives

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carmer, James; Jain, Avni; Bollinger, Jonathan A.

    2015-03-28

    Molecular dynamics simulations and a stochastic Fokker-Planck equation based approach are used to illuminate how position-dependent solvent mobility near one or more tracer particle(s) is affected when tracer-solvent interactions are rationally modified to affect corresponding solvation structure. For tracers in a dense hard-sphere fluid, we compare two types of tracer-solvent interactions: (1) a hard-sphere-like interaction, and (2) a soft repulsion extending beyond the hard core designed via statistical mechanical theory to enhance tracer mobility at infinite dilution by suppressing coordination-shell structure [Carmer et al., Soft Matter 8, 4083–4089 (2012)]. For the latter case, we show that the mobility of surroundingmore » solvent particles is also increased by addition of the soft repulsive interaction, which helps to rationalize the mechanism underlying the tracer’s enhanced diffusivity. However, if multiple tracer surfaces are in closer proximity (as at higher tracer concentrations), similar interactions that disrupt local solvation structure instead suppress the position-dependent solvent dynamics.« less

  16. Fractal continuum model for tracer transport in a porous medium.

    PubMed

    Herrera-Hernández, E C; Coronado, M; Hernández-Coronado, H

    2013-12-01

    A model based on the fractal continuum approach is proposed to describe tracer transport in fractal porous media. The original approach has been extended to treat tracer transport and to include systems with radial and uniform flow, which are cases of interest in geoscience. The models involve advection due to the fluid motion in the fractal continuum and dispersion whose mathematical expression is taken from percolation theory. The resulting advective-dispersive equations are numerically solved for continuous and for pulse tracer injection. The tracer profile and the tracer breakthrough curve are evaluated and analyzed in terms of the fractal parameters. It has been found in this work that anomalous transport frequently appears, and a condition on the fractal parameter values to predict when sub- or superdiffusion might be expected has been obtained. The fingerprints of fractality on the tracer breakthrough curve in the explored parameter window consist of an early tracer breakthrough and long tail curves for the spherical and uniform flow cases, and symmetric short tailed curves for the radial flow case.

  17. Tracer Lamination in the Stratosphere: A Global Climatology

    NASA Technical Reports Server (NTRS)

    Appenzeller, Christof; Holton, James R.

    1997-01-01

    Vertical soundings of stratospheric ozone often exhibit laminated tracer structures characterized by strong vertical tracer gradients. The change in time of these gradients is used to define a tracer lamination rate. It is shown that this quantity can be calculated by the cross product of the horizontal temperature and horizontal tracer gradients. A climatology based on UARS satellite-borne ozone data and on ozone-like pseudotracer data is presented. Three stratospheric regions with high lamination rates were found: the part of the stratospheric overworld which is influenced by the polar vortex, the part of the lowermost stratosphere which is influenced by the tropopause and a third region in the subtropical lower stratosphere mainly characterized with strong vertical shear. High lamination rates in the stratospheric overworld were absent during summer, whereas in the lowermost stratosphere high lamination rates were found year-round. This is consistent with the occurrence and seasonal variation of the horizontal tracer gradient and vertical shear necessary for tilting the tracer surfaces. During winter, high lamination rates associated with the stratospheric polar vortex are present down to approximately 100 hPa. Several features of the derived climatology are roughly consistent with earlier balloon-borne studies. The patterns in the southern and northern hemisphere are comparable, but details differ as anticipated from a less disturbed and more symmetric southern polar vortex.

  18. A dual tracer ratio method for comparative emission measurements in an experimental dairy housing

    NASA Astrophysics Data System (ADS)

    Mohn, Joachim; Zeyer, Kerstin; Keck, Margret; Keller, Markus; Zähner, Michael; Poteko, Jernej; Emmenegger, Lukas; Schrade, Sabine

    2018-04-01

    Agriculture, and in particular dairy farming, is an important source of ammonia (NH3) and non-carbon dioxide greenhouse gas (GHG) emissions. This calls for the development and quantification of effective mitigation strategies. Our study presents the implementation of a dual tracer ratio method in a novel experimental dairy housing with two identical, but spatially separated housing areas. Modular design and flexible floor elements allow the assessment of structural, process engineering and organisational abatement measures at practical scale. Thereby, the emission reduction potential of specific abatement measures can be quantified in relation to a reference system. Emissions in the naturally ventilated housing are determined by continuous dosing of two artificial tracers (sulphur hexafluoride SF6, trifluoromethylsulphur pentafluoride SF5CF3) and their real-time detection in the ppt range with an optimized GC-ECD method. The two tracers are dosed into different experimental sections, which enables the independent assessment of both housing areas. Mass flow emissions of NH3 and GHGs are quantified by areal dosing of tracer gases and multipoint sampling as well as real-time analysis of both tracer and target gases. Validation experiments demonstrate that the technique is suitable for both areal and point emission sources and achieves an uncertainty of less than 10% for the mass emissions of NH3, methane (CH4) and carbon dioxide (CO2), which is superior to other currently available methods. Comparative emission measurements in this experimental dairy housing will provide reliable, currently unavailable information on emissions for Swiss dairy farming and demonstrate the reduction potential of mitigation measures for NH3, GHGs and potentially other pollutants.

  19. Nested Tracer Studies In Catchment Hydrology: Towards A Multiscale Understanding of Runoff Generation and Catchment Funtioning

    NASA Astrophysics Data System (ADS)

    Soulsby, C.; Rodgers, P.; Malcolm, I. A.; Dunn, S.

    Geochemical and isotopic tracers have been shown to have widespread utility in catch- ment hydrology in terms of identifying hydrological source areas and characterising residence time distributions. In many cases application of tracer techniques has pro- vided insights into catchment functioning that could not be obtained from hydromet- ric and/or modelling studies alone. This paper will show how the use of tracers has contributed to an evolving perceptual model of hydrological pathways and runoff gen- eration processes in catchments in the Scottish highlands. In particular the paper will focus on the different insights that are gained at three different scales of analysis; (a) nested sub-catchments within a mesoscale (ca. 200 square kilometers) experimen- tal catchment; (b) hillslope-riparian interactions and (c) stream bed fluxes. Nested hydrometric and hydrochemical monitoring within the mesoscale Feugh catchment identified three main hydrological response units: (i) plateau peatlands which gener- ated saturation overland flow in the catchment headwaters, (ii) steep valley hillslopes which drain from the plateaux into (iii) alluvial and drift aquifers in the valley bottoms. End Member Mixing Analysis (EMMA) in 8 nested sub-catchments indicated that that stream water tracer concentrations can be modelled in terms of 2 dominant runoff pro- cesses; overland flow from the peat and groundwater from the drift aquifers. Ground- water contributions generally increased with catchment size, though this was moder- ated by the characteristics of individual sub-basins, with drift cover being particularly important. Hillslope riparian interactions were also examined using tracers, hydromet- ric data and a semi-distributed hydrological model. This revealed that in the glaciated, drift covered terrain of the Scottish highlands, extensive valley bottom aquifers effec- tively de-couple hillslope waters from the river channel. Thus, riparian groundwater appears to significantly

  20. Non-universal tracer diffusion in crowded media of non-inert obstacles.

    PubMed

    Ghosh, Surya K; Cherstvy, Andrey G; Metzler, Ralf

    2015-01-21

    We study the diffusion of a tracer particle, which moves in continuum space between a lattice of excluded volume, immobile non-inert obstacles. In particular, we analyse how the strength of the tracer-obstacle interactions and the volume occupancy of the crowders alter the diffusive motion of the tracer. From the details of partitioning of the tracer diffusion modes between trapping states when bound to obstacles and bulk diffusion, we examine the degree of localisation of the tracer in the lattice of crowders. We study the properties of the tracer diffusion in terms of the ensemble and time averaged mean squared displacements, the trapping time distributions, the amplitude variation of the time averaged mean squared displacements, and the non-Gaussianity parameter of the diffusing tracer. We conclude that tracer-obstacle adsorption and binding triggers a transient anomalous diffusion. From a very narrow spread of recorded individual time averaged trajectories we exclude continuous type random walk processes as the underlying physical model of the tracer diffusion in our system. For moderate tracer-crowder attraction the motion is found to be fully ergodic, while at stronger attraction strength a transient disparity between ensemble and time averaged mean squared displacements occurs. We also put our results into perspective with findings from experimental single-particle tracking and simulations of the diffusion of tagged tracers in dense crowded suspensions. Our results have implications for the diffusion, transport, and spreading of chemical components in highly crowded environments inside living cells and other structured liquids.

  1. Lattice-Boltzmann simulations of microswimmer-tracer interactions

    NASA Astrophysics Data System (ADS)

    de Graaf, Joost; Stenhammar, Joakim

    2017-02-01

    Hydrodynamic interactions in systems composed of self-propelled particles, such as swimming microorganisms and passive tracers, have a significant impact on the tracer dynamics compared to the equivalent "dry" sample. However, such interactions are often difficult to take into account in simulations due to their computational cost. Here, we perform a systematic investigation of swimmer-tracer interaction using an efficient force-counterforce-based lattice-Boltzmann (LB) algorithm [De Graaf et al., J. Chem. Phys. 144, 134106 (2016), 10.1063/1.4944962] in order to validate its ability to capture the relevant low-Reynolds-number physics. We show that the LB algorithm reproduces far-field theoretical results well, both in a system with periodic boundary conditions and in a spherical cavity with no-slip walls, for which we derive expressions here. The force-lattice coupling of the LB algorithm leads to a "smearing out" of the flow field, which strongly perturbs the tracer trajectories at close swimmer-tracer separations, and we analyze how this effect can be accurately captured using a simple renormalized hydrodynamic theory. Finally, we show that care must be taken when using LB algorithms to simulate systems of self-propelled particles, since its finite momentum transport time can lead to significant deviations from theoretical predictions based on Stokes flow. These insights should prove relevant to the future study of large-scale microswimmer suspensions using these methods.

  2. Evaluation of Brain Nuclear Medicine Imaging Tracers in a Murine Model of Sepsis-Associated Encephalopathy.

    PubMed

    Szöllősi, Dávid; Hegedűs, Nikolett; Veres, Dániel S; Futó, Ildikó; Horváth, Ildikó; Kovács, Noémi; Martinecz, Bernadett; Dénes, Ádám; Seifert, Daniel; Bergmann, Ralf; Lebeda, Ondřej; Varga, Zoltán; Kaleta, Zoltán; Szigeti, Krisztián; Máthé, Domokos

    2018-05-07

    The purpose of this study was to evaluate a set of widely used nuclear medicine imaging agents as possible methods to study the early effects of systemic inflammation on the living brain in a mouse model of sepsis-associated encephalopathy (SAE). The lipopolysaccharide (LPS)-induced murine systemic inflammation model was selected as a model of SAE. C57BL/6 mice were used. A multimodal imaging protocol was carried out on each animal 4 h following the intravenous administration of LPS using the following tracers: [ 99m Tc][2,2-dimethyl-3-[(3E)-3-oxidoiminobutan-2-yl]azanidylpropyl]-[(3E)-3-hydroxyiminobutan-2-yl]azanide ([ 99m Tc]HMPAO) and ethyl-7-[ 125 I]iodo-5-methyl-6-oxo-4H-imidazo[1,5-a][1,4]benzodiazepine-3-carboxylate ([ 125 I]iomazenil) to measure brain perfusion and neuronal damage, respectively; 2-deoxy-2-[ 18 F]fluoro-D-glucose ([ 18 F]FDG) to measure cerebral glucose uptake. We assessed microglia activity on another group of mice using 2-[6-chloro-2-(4-[ 125 I]iodophenyl)-imidazo[1,2-a]pyridin-3-yl]-N-ethyl-N-methyl-acetamide ([ 125 I]CLINME). Radiotracer uptakes were measured in different brain regions and correlated. Microglia activity was also assessed using immunohistochemistry. Brain glutathione levels were measured to investigate oxidative stress. Significantly reduced perfusion values and significantly enhanced [ 18 F]FDG and [ 125 I]CLINME uptake was measured in the LPS-treated group. Following perfusion compensation, enhanced [ 125 I]iomazenil uptake was measured in the LPS-treated group's hippocampus and cerebellum. In this group, both [ 18 F]FDG and [ 125 I]iomazenil uptake showed highly negative correlation to perfusion measured with ([ 99m Tc]HMPAO uptake in all brain regions. No significant differences were detected in brain glutathione levels between the groups. The CD45 and P2Y12 double-labeling immunohistochemistry showed widespread microglia activation in the LPS-treated group. Our results suggest that [ 125 I]CLINME and [ 99m Tc

  3. Uncertainties in assessing tillage erosion - how appropriate are our measuring techniques?

    NASA Astrophysics Data System (ADS)

    Fiener, Peter; Deumlich, Detlef; Gómez, José A.; Guzmán, Gema; Hardy, Robert; Jague, Emilien A.; Quinton, John; Sommer, Michael; van Oost, Kristof; Wexler, Robert; Wilken, Florian

    2017-04-01

    In undulating arable landscapes tillage erosion is one of the dominant processes initiating lateral transfer of soil and soil constituents. Especially, in relatively dry regions, where tillage erosion can be much larger than water erosion, the associated changes in soil hydraulic properties might have substantial effects upon the sustainable use of soil resources. There have been some studies using different techniques to determine tillage erosion which build the basis for tillage erosion modelling approaches. However, tillage erosion is rather understudied compared to water erosion. The goal of this study was to bring together experts using different techniques to determine tillage erosion in an experimental set-up and to analyse the different results and assess the uncertainties associated with typical model inputs. Tillage erosion on a 50 x 10 m plot was determined after two phases of seven tillage passes performed within a week (simulating 10-14 yrs of tillage). As tracers, two different micro-tracers (magnetite mixed with soil and fluorescent sand) and one macro-tracer (passive Radio-Frequency Identification (RFID) transponders; dia. 3 mm, length 20 mm) were used. Moreover, tillage induced changes in topography were spatially determined for the entire plot with two different terrestrial laser scanners and an UAV-based structure by motion topography analysis. Topography changes were also evaluated at 12 points using buried concrete flagstones as reference. A preliminary analysis of tracer movement indicates substantial differences in tillage induced translocation depending on type of tracer. While the mean translocation of the RFIDs was 0.47 m per pass the mean movement of the micro-tracers was 0.70 m. Substantial differences were also found for the different techniques to determine changes in topography. Overall the experiment underlines the importance of tillage erosion for the lateral transfer of soil and soil constituents, but also shows the large

  4. COMPARISON OF THREE TRACER TESTS AT THE RAFT RIVER GEOTHERMAL SITE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Earl D Mattson; Mitchell Plummer; Carl Palmer

    2011-02-01

    Three conservative tracer tests have been conducted through the Bridge Fault fracture zone at the Raft River Geothermal (RRG) site. All three tests were conducted between injection well RRG-5 and production wells RRG-1 (790 m distance) and RRG-4 (740 m distance). The injection well is used during the summer months to provide pressure support to the production wells. The first test was conducted in 2008 using 136 kg of fluorescein tracer. Two additional tracers were injected in 2010. The first 2010 tracer injected was 100 kg fluorescein disodium hydrate salt on June, 21. The second tracer (100 kg 2,6-naphthalene disulfonicmore » acid sodium salt) was injected one month later on July 21. Sampling of the two productions wells is still being performed to obtain the tail end of the second 2010 tracer test. Tracer concentrations were measured using HPLC with a fluorescence detector. Results for the 2008 test, suggest 80% tracer recover at the two production wells. Of the tracer recovered, 85% of tracer mass was recovered in well RRG-4 indicating a greater flow pathway connection between injection well and RRG-4 than RRG-1. Fluorescein tracer results appear to be similar between the 2008 and 2010 tests for well RRG-4 with peak concentrations arriving approximately 20 days after injection despite the differences between the injection rates for the two tests (~950 gpm to 475 gpm) between the 2008 and 2010. The two 2010 tracer tests will be compared to determine if the results support the hypothesis that rock contraction along the flow pathway due to the 55 oC cooler water injection alters the flow through the ~140 oC reservoir.« less

  5. 99mTc-CXCL8 SPECT to Monitor Disease Activity in Inflammatory Bowel Disease.

    PubMed

    Aarntzen, Erik H J G; Hermsen, Rick; Drenth, Joost P H; Boerman, Otto C; Oyen, Wim J G

    2016-03-01

    Inflammatory bowel diseases (IBDs) are defined as chronic relapsing immune-mediated disorders of the gastrointestinal tract. IBD exacerbations are characterized by recruitment of mainly CXCL8 receptor-expressing activated neutrophils into the intestinal wall, leading to severe damage. Considering its chronic relapsing character, accurate and timely diagnosis of an exacerbation is pivotal for early adaptation of the treatment and reduction of the disease burden. However, endoscopic evaluation is invasive and associated with an increased risk of perforation. We previously developed a (99m)Tc-labeled CXCL8 preparation in preclinical models including colitis and clinical studies. In this study, we investigate the accuracy of (99m)Tc-CXCL8 SPECT to detect and localize disease activity in a prospective series of patients with IBD. Thirty patients (15 Crohns disease, 15 ulcerative colitis) participated, and 92 segmental pairs of histology and (99m)Tc-CXCL8 scans were studied. Imaging was performed after injection of 400 MBq of (99m)Tc-CXCL8. Planar and SPECT images of the abdomen were acquired at 30 min and 4 h after the injection. The overall sensitivity and specificity on a per-patient basis for the detection of active disease were 95% and 44% for (99m)Tc-CXCL8 scan and 71% and 70% for endoscopy. The degree of (99m)Tc-CXCL8 accumulation correlated to the degree of neutrophilic influx in affected mucosa. Sensitivity and specificity on a per-segment basis, calculated from the 92 segmental pairs, were 82% and 72%, negative predictive value was 81%, and overall positive predictive value was 74%. Specificity could be increased at the expense of sensitivity using different cutoffs. In 74 segmental pairs, overall sensitivity and specificity for endoscopy were 74% and 85%, positive predictive value was 81%, and negative predictive value was 79%. (99m)Tc-CXCL8 SPECT provides a novel imaging technique to target neutrophil recruitment to the intestinal wall, especially in moderate

  6. Wirelessly powered micro-tracer enabled by miniaturized antenna and microfluidic channel

    NASA Astrophysics Data System (ADS)

    Duan, G.; Zhao, X.; Seren, H. R.; Chen, C.; Zhang, X.

    2015-12-01

    A miniaturized antenna, 380μm by 380μm in size, was fabricated and integrated with a commercialized passive RFID chip to form a micro-tracer, whose size was 2mm by 1mm in total. The micro-tracer was wirelessly powered and interrogated by a single layer spiral reader antenna through near field coupling. To maximize the working distance, the resonant frequency of micro-tracer and reader antenna were matched at 840MHz. Due to the ultra small size of the tracer antenna, power transfer efficiency decreased dramatically as the distance between tracer antenna and reader antenna increased, thus the working distance of the microtracer was limited within 1mm. To achieve massive operation of the micro-tracer, a microfluidic platform was fabricated with in channel focusing and separation. Acrylic sheets were laser cut to define the channel and cover structure, then bonded together layer by layer with a glass substrate, on which reader antenna was integrated. Pump oil was used as the fluidic media carrying the micro-tracer flowing inside the microfluidic channel. The wireless power transfer and real-time communication was demonstrated with the micro-tracer flowing above the reader antenna, as the ID of the micro-tracer was retrieved and displayed on a computer screen.

  7. In vitro and in vivo comparison of a tailored magnetic particle imaging blood pool tracer with Resovist.

    PubMed

    Kaul, Michael Gerhard; Mummert, Tobias; Jung, Caroline; Salamon, Johannes; Khandhar, Amit P; Ferguson, R Matthew; Kemp, Scott J; Ittrich, Harald; Krishnan, Kannan M; Adam, Gerhard; Knopp, Tobias

    2017-05-07

    Optimizing tracers for individual imaging techniques is an active field of research. The purpose of this study was to perform in vitro and in vivo magnetic particle imaging (MPI) measurements using a new monodisperse and size-optimized tracer, LS-008, and to compare it with the performance of Resovist, the standard MPI tracer. Magnetic particle spectroscopy (MPS) and in vitro MPI measurements were performed in concerns of concentration and amount of tracer in a phantom. In vivo studies were carried out in healthy FVB mice. The first group (n  =  3) received 60 µl LS-008 (87 mM) and the second (n  =  3) diluted Resovist of the same concentration and volume. Tracer injections were performed with a syringe pump during a dynamic MPI scan. For anatomic referencing MRI was applied beforehand of the MPI measurements. Summing up MPS examinations and in vitro MPI experiments, LS-008 showed better sensitivity and spatial resolution than Resovist. In vivo both tracers can visualize the propagation of the bolus through the inferior vena cava. MPI with LS-008 did show less temporal fluctuation artifacts and the pulsation of blood due to respiratory and cardiac cycle was detectable. With LS-008 the aorta was distinguishable from the caval vein while with Resovist this failed. A liver vessel and a vessel structure leading cranially could only be observed with LS-008 and not with Resovist. Beside these structural advantages both tracers showed very different blood half-life. For LS-008 we found 88 min. Resovist did show a fast liver accumulation and a half-life of 13 min. Only with LS-008 the perfusion fraction in liver and kidney was measureable. MPI for angiography can be significantly improved by applying more effective tracers. LS-008 shows a clear improvement concerning the delineation while resolving a larger number of vessels in comparison to Resovist. Therefore, in aspects of quality and quantity LS-008 is clearly favorable for angiographic and

  8. In vitro and in vivo comparison of a tailored magnetic particle imaging blood pool tracer with Resovist

    NASA Astrophysics Data System (ADS)

    Kaul, Michael Gerhard; Mummert, Tobias; Jung, Caroline; Salamon, Johannes; Khandhar, Amit P.; Ferguson, R. Matthew; Kemp, Scott J.; Ittrich, Harald; Krishnan, Kannan M.; Adam, Gerhard; Knopp, Tobias

    2017-05-01

    Optimizing tracers for individual imaging techniques is an active field of research. The purpose of this study was to perform in vitro and in vivo magnetic particle imaging (MPI) measurements using a new monodisperse and size-optimized tracer, LS-008, and to compare it with the performance of Resovist, the standard MPI tracer. Magnetic particle spectroscopy (MPS) and in vitro MPI measurements were performed in concerns of concentration and amount of tracer in a phantom. In vivo studies were carried out in healthy FVB mice. The first group (n  =  3) received 60 µl LS-008 (87 mM) and the second (n  =  3) diluted Resovist of the same concentration and volume. Tracer injections were performed with a syringe pump during a dynamic MPI scan. For anatomic referencing MRI was applied beforehand of the MPI measurements. Summing up MPS examinations and in vitro MPI experiments, LS-008 showed better sensitivity and spatial resolution than Resovist. In vivo both tracers can visualize the propagation of the bolus through the inferior vena cava. MPI with LS-008 did show less temporal fluctuation artifacts and the pulsation of blood due to respiratory and cardiac cycle was detectable. With LS-008 the aorta was distinguishable from the caval vein while with Resovist this failed. A liver vessel and a vessel structure leading cranially could only be observed with LS-008 and not with Resovist. Beside these structural advantages both tracers showed very different blood half-life. For LS-008 we found 88 min. Resovist did show a fast liver accumulation and a half-life of 13 min. Only with LS-008 the perfusion fraction in liver and kidney was measureable. MPI for angiography can be significantly improved by applying more effective tracers. LS-008 shows a clear improvement concerning the delineation while resolving a larger number of vessels in comparison to Resovist. Therefore, in aspects of quality and quantity LS-008 is clearly favorable for angiographic and

  9. Optical detection of tracer species in strongly scattering media.

    PubMed

    Brauser, Eric M; Rose, Peter E; McLennan, John D; Bartl, Michael H

    2015-03-01

    A combination of optical absorption and scattering is used to detect tracer species in a strongly scattering medium. An optical setup was developed, consisting of a dual-beam scattering detection scheme in which sample scattering beam overlaps with the characteristic absorption feature of quantum dot tracer species, while the reference scattering beam is outside any absorption features of the tracer. This scheme was successfully tested in engineered breakthrough tests typical of wastewater and subsurface fluid analysis, as well as in batch analysis of oil and gas reservoir fluids and biological samples. Tracers were detected even under highly scattering conditions, conditions in which conventional absorption or fluorescence methods failed.

  10. A novel double-tracer technique to characterize absorption, distribution, metabolism and excretion (ADME) of [14C]tofogliflozin after oral administration and concomitant intravenous microdose administration of [13C]tofogliflozin in humans.

    PubMed

    Schwab, Dietmar; Portron, Agnes; Backholer, Zoe; Lausecker, Berthold; Kawashima, Kosuke

    2013-06-01

    Human mass balance studies and the assessment of absolute oral bioavailability (F) are usually assessed in separate studies. Intravenous microdose administration of an isotope tracer concomitant to an unlabeled oral dose is an emerging technique to assess F. We report a novel double-tracer approach implemented for tofogliflozin combining oral administration of a radiolabel tracer with concomitant intravenous administration of a stable isotope tracer. Tofogliflozin is a potent and selective sodium/glucose cotransporter 2 inhibitor for the treatment of type 2 diabetes mellitus currently in clinical development. The objectives of the present study were to assess the systemic exposure of major circulating metabolites, excretion balance, F and contribution of renal clearance (CLR) to total clearance (CL) of tofogliflozin in healthy subjects within one study applying a novel double-tracer technique. Six healthy male subjects received 20 mg [(12)C/(14)C]tofogliflozin (3.73 MBq) orally and a concomitant microdose of 0.1 mg [(13)C]tofogliflozin intravenously. Pharmacokinetics of tofogliflozin were determined for the oral and intravenous route; the pharmacokinetics of the metabolites M1 and M5 were determined for the oral route. Quantification of [(12)C]tofogliflozin in plasma and urine and [(13)C]tofogliflozin in plasma was performed by selective LC-MS/MS methods. For the pre-selected metabolites of tofogliflozin, M1 and M5, a validated liquid chromatography-tandem mass spectrometry (LC-MS/MS) was applied to plasma and urine samples. Total radioactivity was assessed in plasma, urine and feces. Pharmacokinetic analysis was conducted by non-compartmental methods. The pharmacokinetics of tofogliflozin in healthy subjects were characterized by an F of 97.5 ± 12.3 %, CL of 10.0 ± 1.3 l/h and volume of distribution at steady-state (V(ss)) of 50.6 ± 6.7 l. The main route of elimination of total drug-related material was by excretion into urine (77.0 ± 4.1 % of the dose). The

  11. Infection with Trypanosoma cruzi TcII and TcI in free-ranging population of lion tamarins (Leontopithecus spp): an 11-year follow-up.

    PubMed

    Lisboa, Cristiane Varella; Monteiro, Rafael Veríssimo; Martins, Andreia Fonseca; Xavier, Samantha Cristina das Chagas; Lima, Valdirene Dos Santos; Jansen, Ana Maria

    2015-05-01

    Here, we present a review of the dataset resulting from the 11-years follow-up of Trypanosoma cruzi infection in free-ranging populations of Leontopithecus rosalia (golden lion tamarin) and Leontopithecus chrysomelas (golden-headed lion tamarin) from distinct forest fragments in Atlantic Coastal Rainforest. Additionally, we present new data regarding T. cruzi infection of small mammals (rodents and marsupials) that live in the same areas as golden lion tamarins and characterisation at discrete typing unit (DTU) level of 77 of these isolates. DTU TcII was found to exclusively infect primates, while TcI infected Didelphis aurita and lion tamarins. The majority of T. cruzi isolates derived from L. rosalia were shown to be TcII (33 out 42) Nine T. cruzi isolates displayed a TcI profile. Golden-headed lion tamarins demonstrated to be excellent reservoirs of TcII, as 24 of 26 T. cruzi isolates exhibited the TcII profile. We concluded the following: (i) the transmission cycle of T. cruzi in a same host species and forest fragment is modified over time, (ii) the infectivity competence of the golden lion tamarin population fluctuates in waves that peak every other year and (iii) both golden and golden-headed lion tamarins are able to maintain long-lasting infections by TcII and TcI.

  12. Heat and solute tracers: how do they compare in heterogeneous aquifers?

    PubMed

    Irvine, Dylan J; Simmons, Craig T; Werner, Adrian D; Graf, Thomas

    2015-04-01

    A comparison of groundwater velocity in heterogeneous aquifers estimated from hydraulic methods, heat and solute tracers was made using numerical simulations. Aquifer heterogeneity was described by geostatistical properties of the Borden, Cape Cod, North Bay, and MADE aquifers. Both heat and solute tracers displayed little systematic under- or over-estimation in velocity relative to a hydraulic control. The worst cases were under-estimates of 6.63% for solute and 2.13% for the heat tracer. Both under- and over-estimation of velocity from the heat tracer relative to the solute tracer occurred. Differences between the estimates from the tracer methods increased as the mean velocity decreased, owing to differences in rates of molecular diffusion and thermal conduction. The variance in estimated velocity using all methods increased as the variance in log-hydraulic conductivity (K) and correlation length scales increased. The variance in velocity for each scenario was remarkably small when compared to σ2 ln(K) for all methods tested. The largest variability identified was for the solute tracer where 95% of velocity estimates ranged by a factor of 19 in simulations where 95% of the K values varied by almost four orders of magnitude. For the same K-fields, this range was a factor of 11 for the heat tracer. The variance in estimated velocity was always lowest when using heat as a tracer. The study results suggest that a solute tracer will provide more understanding about the variance in velocity caused by aquifer heterogeneity and a heat tracer provides a better approximation of the mean velocity. © 2013, National Ground Water Association.

  13. Neutrally buoyant tracers in hydrogeophysics: Field demonstration in fractured rock

    NASA Astrophysics Data System (ADS)

    Shakas, Alexis; Linde, Niklas; Baron, Ludovic; Selker, John; Gerard, Marie-Françoise; Lavenant, Nicolas; Bour, Olivier; Le Borgne, Tanguy

    2017-04-01

    Electrical and electromagnetic methods are extensively used to map electrically conductive tracers within hydrogeologic systems. Often, the tracers used consist of dissolved salt in water, leading to a denser mixture than the ambient formation water. Density effects are often ignored and rarely modeled but can dramatically affect transport behavior and introduce dynamics that are unrepresentative of the response obtained with classical tracers (e.g., uranine). We introduce a neutrally buoyant tracer consisting of a mixture of salt, water, and ethanol and monitor its movement during push-pull experiments in a fractured rock aquifer using ground-penetrating radar. Our results indicate a largely reversible transport process and agree with uranine-based push-pull experiments at the site, which is in contrast to results obtained using dense saline tracers. We argue that a shift toward neutrally buoyant tracers in both porous and fractured media would advance hydrogeophysical research and enhance its utility in hydrogeology.

  14. Toxicological and ecotoxicological assessment of water tracers

    NASA Astrophysics Data System (ADS)

    Behrens, H.; Beims, U.; Dieter, H.; Dietze, G.; Eikmann, T.; Grummt, T.; Hanisch, H.; Henseling, H.; Käß, W.; Kerndorff, H.; Leibundgut, C.; Müller-Wegener, U.; Rönnefahrt, I.; Scharenberg, B.; Schleyer, R.; Schloz, W.; Tilkes, F.

    2001-06-01

    Uncertainties regarding possible negative effects on the environment or on human health of authorizing tracing experiments in groundwater and surface waters led to the establishment of a Working Group at the German Federal Environmental Agency (Umweltbundesamt - UBA) for conducting a toxicological and ecotoxicological assessment. A total of 17 water tracers was assessed by the Working Group on the basis of the results of toxicological tests, the available literature, and the group's expert knowledge. In the future, tracers that pose a risk to the environment or to human health should no longer be used. Nevertheless, there are a number of tracers that could be used in hydrogeological and hydrological investigations for water-pollution-control purposes with no adverse environmental impact.

  15. A finite element code for modelling tracer transport in a non-isothermal two-phase flow system for CO2 geological storage characterization

    NASA Astrophysics Data System (ADS)

    Tong, F.; Niemi, A. P.; Yang, Z.; Fagerlund, F.; Licha, T.; Sauter, M.

    2011-12-01

    This paper presents a new finite element method (FEM) code for modeling tracer transport in a non-isothermal two-phase flow system. The main intended application is simulation of the movement of so-called novel tracers for the purpose of characterization of geologically stored CO2 and its phase partitioning and migration in deep saline formations. The governing equations are based on the conservation of mass and energy. Among the phenomena accounted for are liquid-phase flow, gas flow, heat transport and the movement of the novel tracers. The movement of tracers includes diffusion and the advection associated with the gas and liquid flow. The temperature, gas pressure, suction, concentration of tracer in liquid phase and concentration of tracer in gas phase are chosen as the five primary variables. Parameters such as the density, viscosity, thermal expansion coefficient are expressed in terms of the primary variables. The governing equations are discretized in space using the Galerkin finite element formulation, and are discretized in time by one-dimensional finite difference scheme. This leads to an ill-conditioned FEM equation that has many small entries along the diagonal of the non-symmetric coefficient matrix. In order to deal with the problem of non-symmetric ill-conditioned matrix equation, special techniques are introduced . Firstly, only nonzero elements of the matrix need to be stored. Secondly, it is avoided to directly solve the whole large matrix. Thirdly, a strategy has been used to keep the diversity of solution methods in the calculation process. Additionally, an efficient adaptive mesh technique is included in the code in order to track the wetting front. The code has been validated against several classical analytical solutions, and will be applied for simulating the CO2 injection experiment to be carried out at the Heletz site, Israel, as part of the EU FP7 project MUSTANG.

  16. New horizons in cardiac innervation imaging: introduction of novel 18F-labeled PET tracers.

    PubMed

    Kobayashi, Ryohei; Chen, Xinyu; Werner, Rudolf A; Lapa, Constantin; Javadi, Mehrbod S; Higuchi, Takahiro

    2017-12-01

    Cardiac sympathetic nervous activity can be uniquely visualized by non-invasive radionuclide imaging techniques due to the fast growing and widespread application of nuclear cardiology in the last few years. The norepinephrine analogue 123 I-meta-iodobenzylguanidine ( 123 I-MIBG) is a single photon emission computed tomography (SPECT) tracer for the clinical implementation of sympathetic nervous imaging for both diagnosis and prognosis of heart failure. Meanwhile, positron emission tomography (PET) imaging has become increasingly attractive because of its higher spatial and temporal resolution compared to SPECT, which allows regional functional and dynamic kinetic analysis. Nevertheless, wider use of cardiac sympathetic nervous PET imaging is still limited mainly due to the demand of costly on-site cyclotrons, which are required for the production of conventional 11 C-labeled (radiological half-life, 20 min) PET tracers. Most recently, more promising 18 F-labeled (half-life, 110 min) PET radiopharmaceuticals targeting sympathetic nervous system have been introduced. These tracers optimize PET imaging and, by using delivery networks, cost less to produce. In this article, the latest advances of sympathetic nervous imaging using 18 F-labeled radiotracers along with their possible applications are reviewed.

  17. [99mTc(V)-DMSA accumulation in gynecomastia].

    PubMed

    Ohta, H

    1998-11-01

    The accumulation of 99mTc(V)-DMSA in bilateral breasts was recognized in a 60-year-old male with drug-induced gynecomastia. There are some reports describing 99mTc(V)-DMSA accumulation in normal female breast, fibrous dysplasia of the breast and metastatic lesions of breast carcinoma, but to my knowledge, there have been no reports describing 99mTc(V)-DMSA accumulation in gynecomastia.

  18. Tc17 cells in patients with uterine cervical cancer.

    PubMed

    Zhang, Yan; Hou, Fei; Liu, Xin; Ma, Daoxin; Zhang, Youzhong; Kong, Beihua; Cui, Baoxia

    2014-01-01

    The existence of Tc17 cells was recently shown in several types of infectious and autoimmune diseases, but their distribution and functions in uterine cervical cancer (UCC) have not been fully elucidated. The frequency of Tc17 cells in peripheral blood samples obtained from UCC patients, cervical intraepithelial neoplasia (CIN) patients and healthy controls was determined by flow cytometry. Besides, the prevalence of Tc17 cells and their relationships to Th17 cells and Foxp3-expressing T cells as well as microvessels in tissue samples of the patients were assessed by immunohistochemistry staining. Compared to controls, patients with UCC or CIN had a higher proportion of Tc17 cells in both peripheral blood and cervical tissues, but the level of Tc17 cells in UCC tissues was significantly higher than that in CIN tissues. Besides, the increased level of Tc17 in UCC patients was associated with the status of pelvic lymph node metastases and increased microvessel density. Finally, significant correlations of infiltration between Tc17 cells and Th17 cells or Foxp3-expressing T cells were observed in UCC and CIN tissues. This study indicates that Tc17 cell infiltration in cervical cancers is associated with cancer progression accompanied by increased infiltrations of Th17 cells and regulatory T cells as well as promoted tumor vasculogenesis.

  19. Tc17 Cells in Patients with Uterine Cervical Cancer

    PubMed Central

    Zhang, Yan; Hou, Fei; Liu, Xin; Ma, Daoxin; Zhang, Youzhong; Kong, Beihua; Cui, Baoxia

    2014-01-01

    Background The existence of Tc17 cells was recently shown in several types of infectious and autoimmune diseases, but their distribution and functions in uterine cervical cancer (UCC) have not been fully elucidated. Methods The frequency of Tc17 cells in peripheral blood samples obtained from UCC patients, cervical intraepithelial neoplasia (CIN) patients and healthy controls was determined by flow cytometry. Besides, the prevalence of Tc17 cells and their relationships to Th17 cells and Foxp3-expressing T cells as well as microvessels in tissue samples of the patients were assessed by immunohistochemistry staining. Results Compared to controls, patients with UCC or CIN had a higher proportion of Tc17 cells in both peripheral blood and cervical tissues, but the level of Tc17 cells in UCC tissues was significantly higher than that in CIN tissues. Besides, the increased level of Tc17 in UCC patients was associated with the status of pelvic lymph node metastases and increased microvessel density. Finally, significant correlations of infiltration between Tc17 cells and Th17 cells or Foxp3-expressing T cells were observed in UCC and CIN tissues. Conclusions This study indicates that Tc17 cell infiltration in cervical cancers is associated with cancer progression accompanied by increased infiltrations of Th17 cells and regulatory T cells as well as promoted tumor vasculogenesis. PMID:24523865

  20. A Diffusion MRI Tractography Connectome of the Mouse Brain and Comparison with Neuronal Tracer Data

    PubMed Central

    Calabrese, Evan; Badea, Alexandra; Cofer, Gary; Qi, Yi; Johnson, G. Allan

    2015-01-01

    Interest in structural brain connectivity has grown with the understanding that abnormal neural connections may play a role in neurologic and psychiatric diseases. Small animal connectivity mapping techniques are particularly important for identifying aberrant connectivity in disease models. Diffusion magnetic resonance imaging tractography can provide nondestructive, 3D, brain-wide connectivity maps, but has historically been limited by low spatial resolution, low signal-to-noise ratio, and the difficulty in estimating multiple fiber orientations within a single image voxel. Small animal diffusion tractography can be substantially improved through the combination of ex vivo MRI with exogenous contrast agents, advanced diffusion acquisition and reconstruction techniques, and probabilistic fiber tracking. Here, we present a comprehensive, probabilistic tractography connectome of the mouse brain at microscopic resolution, and a comparison of these data with a neuronal tracer-based connectivity data from the Allen Brain Atlas. This work serves as a reference database for future tractography studies in the mouse brain, and demonstrates the fundamental differences between tractography and neuronal tracer data. PMID:26048951

  1. Synthesis, Characterization, and Initial Biological Evaluation of [99m Tc]Tc-Tricarbonyl-labeled DPA-α-MSH Peptide Derivatives for Potential Melanoma Imaging.

    PubMed

    Gao, Feng; Sihver, Wiebke; Bergmann, Ralf; Belter, Birgit; Bolzati, Cristina; Salvarese, Nicola; Steinbach, Jörg; Pietzsch, Jens; Pietzsch, Hans-Jürgen

    2018-06-06

    α-Melanocyte stimulating hormone (α-MSH) derivatives target the melanocortin-1 receptor (MC1R) specifically and selectively. In this study, the α-MSH-derived peptide NAP-NS1 (Nle-Asp-His-d-Phe-Arg-Trp-Gly-NH 2 ) with and without linkers was conjugated with 5-(bis(pyridin-2-ylmethyl)amino)pentanoic acid (DPA-COOH) and labeled with [ 99m Tc]Tc-tricarbonyl by two methods. With the one-pot method the labeling was faster than with the two-pot method, while obtaining similarly high yields. Negligible trans-chelation and high stability in physiological solutions was determined for the [ 99m Tc]Tc-tricarbonyl-peptide conjugates. Coupling an ethylene glycol (EG)-based linker increased the hydrophilicity. The peptide derivatives displayed high binding affinity in murine B16F10 melanoma cells as well as in human MeWo and TXM13 melanoma cell homogenates. Preliminary in vivo studies with one of the [ 99m Tc]Tc-tricarbonyl-peptide conjugates showed good stability in blood and both renal and hepatobiliary excretion. Biodistribution was performed on healthy rats to gain initial insight into the potential relevance of the 99m Tc-labeled peptides for in vivo imaging. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Urban Pollutant Transport and Infiltration into Buildings Using Perfluorocarbon Tracers.

    PubMed

    Matthews, James C; Bacak, Asan; Khan, M Anwar H; Wright, Matthew D; Priestley, Michael; Martin, Damien; Percival, Carl J; Shallcross, Dudley E

    2017-02-21

    People spend the majority of their time indoors and therefore the quality of indoor air is worthy of investigation; indoor air quality is affected by indoor sources of pollutants and from pollutants entering buildings from outdoors. In this study, unique perfluorocarbon tracers were released in five experiments at a 100 m and ~2 km distance from a large university building in Manchester, UK and tracer was also released inside the building to measure the amount of outdoor material penetrating into buildings and the flow of material within the building itself. Air samples of the tracer were taken in several rooms within the building, and a CO₂ tracer was used within the building to estimate air-exchange rates. Air-exchange rates were found to vary between 0.57 and 10.90 per hour. Indoor perfluorocarbon tracer concentrations were paired to outdoor tracer concentrations, and in-out ratios were found to vary between 0.01 and 3.6. The largest room with the lowest air-exchange rate exhibited elevated tracer concentrations for over 60 min after the release had finished, but generally had the lowest concentrations, the room with the highest ventilation rates had the highest concentration over 30 min, but the peak decayed more rapidly. Tracer concentrations indoors compared to outdoors imply that pollutants remain within buildings after they have cleared outside, which must be considered when evaluating human exposure to outdoor pollutants.

  3. Urban Pollutant Transport and Infiltration into Buildings Using Perfluorocarbon Tracers

    PubMed Central

    Matthews, James C.; Bacak, Asan; Khan, M. Anwar H.; Wright, Matthew D.; Priestley, Michael; Martin, Damien; Percival, Carl J.; Shallcross, Dudley E.

    2017-01-01

    People spend the majority of their time indoors and therefore the quality of indoor air is worthy of investigation; indoor air quality is affected by indoor sources of pollutants and from pollutants entering buildings from outdoors. In this study, unique perfluorocarbon tracers were released in five experiments at a 100 m and ~2 km distance from a large university building in Manchester, UK and tracer was also released inside the building to measure the amount of outdoor material penetrating into buildings and the flow of material within the building itself. Air samples of the tracer were taken in several rooms within the building, and a CO2 tracer was used within the building to estimate air-exchange rates. Air-exchange rates were found to vary between 0.57 and 10.90 per hour. Indoor perfluorocarbon tracer concentrations were paired to outdoor tracer concentrations, and in-out ratios were found to vary between 0.01 and 3.6. The largest room with the lowest air-exchange rate exhibited elevated tracer concentrations for over 60 min after the release had finished, but generally had the lowest concentrations, the room with the highest ventilation rates had the highest concentration over 30 min, but the peak decayed more rapidly. Tracer concentrations indoors compared to outdoors imply that pollutants remain within buildings after they have cleared outside, which must be considered when evaluating human exposure to outdoor pollutants. PMID:28230812

  4. Re-Search for Extinct 99Tc and 98Tc in the Early Solar System

    NASA Astrophysics Data System (ADS)

    Yin, Q.; Jagoutz, E.; Wanke, H.

    1992-07-01

    The recent advances in negative thermal ionization mass spectrometry (N-TIMS) of Re and Os (Creaser et al., 1991) offer a new chance to search for isotopic anomalies of ruthenium (Ru) (and possibly Mo) in meteorites. The Ru isotopes are particularly important since they contain two daughter decay products of technicium, ^98Tc (tau(sub)1/2=4.2x10^6 yr) and ^99Tc (tau(sub)1/2=2.1x10^5 yr). Natural Tc is now extinct on Earth due to their short half-life, but may have been present in the early solar system; Ru isotopes might also bear witness of the various processes of nucleosynthesis and of the imperfect mixing of their products in the pre-solar nebula; Ru isotopic composition in fission is drastically different from natural; ^99Tc is crucial because of its very short half-life and is observed directly for several half-lives in s-process-enriched stars during the thermally pulsing, AGB (asymptotic giant branch) phase of evolution. The probability of detecting ^99Tc in this type of stars is typically 70% (Smith and Lambert, 1988). The chemical similarities between Ru and Os yield correspondingly high ionization efficiency for Ru with N-TIMS. Ru is obtained as a byproduct of Os chemistry, as Ru co-distills with Os. This unique combination conveniently enables a survey for extinct Tc by determining isotopic composition of Ru on a wide range of samples together with extensive studies of Re-Os system in geochemical community in the years to come. These arguments prompted us to carry out a systematic re-search for Ru isotopic anomalies initiated by Herr and coworkers more than 30 years ago (Herr et al., 1958). We have measured Ru isotopic composition in one bulk sample and a magnetic fraction of Maralinga carbonaceous chondrite and one bulk sample of the iron meteorite Gibeon. The bulk sample of Maralinga is found to be isotopically indistinguishable from the terrestrial values within analytical uncertainties. In the magnetic fraction, however, a positive deviation (0

  5. Effect of different thickness of material filter on Tc-99m spectra and performance parameters of gamma camera

    NASA Astrophysics Data System (ADS)

    Nazifah, A.; Norhanna, S.; Shah, S. I.; Zakaria, A.

    2014-11-01

    This study aimed to investigate the effects of material filter technique on Tc-99m spectra and performance parameters of Philip ADAC forte dual head gamma camera. Thickness of material filter was selected on the basis of percentage attenuation of various gamma ray energies by different thicknesses of zinc material. A cylindrical source tank of NEMA single photon emission computed tomography (SPECT) Triple Line Source Phantom filled with water and Tc-99m radionuclide injected was used for spectra, uniformity and sensitivity measurements. Vinyl plastic tube was used as a line source for spatial resolution. Images for uniformity were reconstructed by filtered back projection method. Butterworth filter of order 5 and cut off frequency 0.35 cycles/cm was selected. Chang's attenuation correction method was applied by selecting 0.13/cm linear attenuation coefficient. Count rate was decreased with material filter from the compton region of Tc-99m energy spectrum, also from the photopeak region. Spatial resolution was improved. However, uniformity of tomographic image was equivocal, and system volume sensitivity was reduced by material filter. Material filter improved system's spatial resolution. Therefore, the technique may be used for phantom studies to improve the image quality.

  6. Tracer and hydrometric techniques to determine the contribution of glacier melt to a proglacial stream in the Ötztal Alps (Tyrol, Austria)

    NASA Astrophysics Data System (ADS)

    Schmieder, Jan; Marke, Thomas; Strasser, Ulrich

    2016-04-01

    Glaciers are important seasonal water contributors in many mountainous landscapes. For water resources management it is important to know about the timing and amount of released glacier melt water, especially in downstream regions where the water is needed (hydropower, drinking water) or where it represents a potential risk (drought, flood). Seasonal availability of melt water is strongly dependent on boundary layer atmospheric processes and becomes even more relevant in a changing climate. Environmental tracers are a useful tool in the assessment of snow and ice water resources, because they provide information about the sources, flow paths and traveling times of water contributing to streamflow at the catchment scale. Previously, high-elevation tracer studies throughout the Alps have been scarce as they require intense field work in remote areas. However, hydrometric and meteorological measurements combined with tracer analyses help to unravel streamflow composition and improve the understanding of hydroclimatological processes. On top of that, empirical studies are necessary to parameterize and validate hydrological models in more process-oriented ways, rather than comparing total measured and simulated runoff only. In the present study three approaches are applied to derive glacier melt contributions to a proglacial stream at the seasonal scale and to identify their individual advances and limitations. Tracers used for each approach are (1) electrical conductivity, (2) stable isotopes of water and (3) heavy metals. The field work was conducted during the summer of 2015 in the glaciated (35%) high-elevation catchment of the Hochjochbach, a small sub-basin (17 km²) of the Ötztaler Ache river in the Austrian Alps, ranging from 2400 to 3500 m.a.s.l. in elevation. Hydroclimatological data was provided by an automatic weather station and a gauging station equipped with a pressure transducer. Water samples from shallow groundwater, streamflow, glacier and snow melt

  7. Singularity in the positive Hall coeffcient near pre-onset temperatures in high-Tc superconductors

    NASA Astrophysics Data System (ADS)

    Vezzoli, G. C.; Chen, M. F.; Craver, F.; Moon, B. M.; Safari, A.; Burke, T.; Stanley, W.

    1990-10-01

    Hall measurements using continuous extremely slow cooling and reheating rates as well as employing eqiulibrium point-by-point conventional techniques reveals a clear anomally in RH at pre-onset temperatures near Tc in polycrystalline samples Y1Ba2Cu3O7 and Bi2Sr2Ca2Cu3O10. The anomaly has the appearance of a singularity of Dirac-delta function which parallels earlier work on La1-xSrxCuO4. Recent single crystal work on the Bi-containing high-Tc superconductor is in accord with a clearcut anomaly. The singularity is tentatively interpreted to be associated (upon cooling) with initially the removal of positive holes from the hopping conduction system of the normal state such as from the increased concentration of bound virtual excitons due to increased exciton and hole lifetimes at low temperature. Subsequently the formation of Cooper pairs by mediation from these centers (bound-holes) and/or bound excitons) may cause an ionization of these bound virtual excitons thereby re-introducing holes and electrons into the conduction system at Tc.

  8. Tc-99m Ethylenedicysteine and Tc-99m Dimercaptosuccinic Acid Scintigraphy-Comparison of the Two for Detection of Scarring and Differential Cortical Function.

    PubMed

    Dharmalingam, Anitha; Pawar, Shwetal U; Parelkar, Sandesh V; Shetye, Suruchi S; Ghorpade, Mangala K; Tilve, Gundu H

    2017-01-01

    The differential cortical function obtained by Tc-99m EC is comparable to that of Tc-99m DMSA. However, identification of scars on Tc-99m EC images needs to be studied. The aim of the study is to evaluate role of Tc-99m EC for detection of scarring and differential cortical function by comparing with Tc-99m DMSA. Prospective observational study of recurrent UTI; minimum 6 weeks after acute episode; when urine examination is negative for pus cells. Forty-seven children with normal positioned kidneys underwent Tc-99m EC and DMSA scintigraphy. The DRF and cortical phase images of both studies in the same image matrix size were evaluated by two independent observers for scarring; Tc-99m DMSA was considered as the gold standard. MS Excel 2007 and GraphPad Instat V3.1 and ROC analysis. There was no significant difference in the detection of scarring using two studies with Cohen's kappa coefficient (κ) 0.932. The sensitivity and specificity of Tc-99m EC for detection of scarring was 98.75% and 99.15%, respectively. There was good agreement between the differential cortical function calculated using two studies. The summed Tc-99m EC images with an acceptable high image contrast allow detection of cortical scarring in patients with normal kidney positions. It is an excellent single-modality comprehensive investigational agent for renal parenchymal defects, function, and excretion evaluation with the added advantages of lower cost, convenience, and low radiation exposure to the child.

  9. Inhibitory effect of trans-caryophyllene (TC) on leukocyte-endothelial attachment.

    PubMed

    Zhang, Zhen; Yang, Chunfeng; Dai, Xinlun; Ao, Yu; Li, Yumei

    2017-08-15

    trans-Caryophyllene (TC) is a major component found in the essential oils of many spices and foods/medicinal plants. It is a natural sesquiterpene and has been the subject of numerous studies. However, the effects of TC on vascular inflammation remain unknown. In this study, we reported that TC treatment in human umbilical vein endothelial cells (HUVECs) prevented attachment of monocytic leukemia cell line THP-1 cells to endothelial cells. In addition, in vivo results indicate that TC inhibited macrophage infiltration to the aortic surface and reduced total serum levels of cholesterol and triglycerides. Importantly, administration of TC could inhibit the induction of vascular cell adhesion molecule-1 (VCAM-1) both in vitro and in vivo. Notably, our data indicate that the inhibitory effects of TC on the expression of VCAM-1 are mediated by the JAK2/STAT1/IRF-1 pathway. TC is a specific agonist of the type 2 cannabinoid receptor (CB2R). Importantly, we further verified that the inhibitory effects of TC on the expression of IRF-1 and VCAM-1 are dependent on activation of CB2R. Inhibition of CB2R by either specific inhibitors or RNA interference abolished the inhibitory effects of TC on the expression of IRF-1 and VCAM-1. Our results suggest that TC might have a capacity to suppress the development of atherosclerosis. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Development of Standardized Mobile Tracer Correlation Approach for Large Area Emission Measurements (DRAFT UNDER EPA REVIEW)

    NASA Astrophysics Data System (ADS)

    Foster-wittig, T. A.; Thoma, E.; Green, R.; Hater, G.; Swan, N.; Chanton, J.

    2013-12-01

    conditions). The trials tested a novel tracer gas (acetylene), chosen for its performance and cost characteristics. This presentation will summarize method development activities for the field test trials (107 test days, with repeat measurements at 14 separate landfill sites). In addition to a brief description of the measurement technology, the method performance will be described, and primary data quality indicators and use conditions will be explored. Because measurements were taken under daylight and a variety of atmospheric conditions, the range of distance and wind conditions allows us to make conclusions about the strengths and limitations of the method. This enables us to show when and where it is possible to make a quality measurement using this technique and therefore develop a standardized method for large area emission measurements. Green, R. et al (2010). 'Methane Emission Measured at Two California Landfills by OTM-10 and an Acetylene Tracer Method.' Global Waste Management Symposium. San Antonio, Texas. Scheutz, C. et al. (2011). 'Quantification of multiple methane emission sources at landfills using a double tracer technique." Waste Management 31(5): 1009-1017. Thoma, E., et al (2009). 'Development of EPA OTM 10 for landfill applications." Journal of Environmental Engineering 136(8): 769-776.

  11. Infection with Trypanosoma cruzi TcII and TcI in free-ranging population of lion tamarins (Leontopithecus spp): an 11-year follow-up

    PubMed Central

    Lisboa, Cristiane Varella; Monteiro, Rafael Veríssimo; Martins, Andreia Fonseca; Xavier, Samantha Cristina das Chagas; Lima, Valdirene dos Santos; Jansen, Ana Maria

    2015-01-01

    Here, we present a review of the dataset resulting from the 11-years follow-up of Trypanosoma cruzi infection in free-ranging populations of Leontopithecus rosalia (golden lion tamarin) and Leontopithecus chrysomelas (golden-headed lion tamarin) from distinct forest fragments in Atlantic Coastal Rainforest. Additionally, we present new data regarding T. cruzi infection of small mammals (rodents and marsupials) that live in the same areas as golden lion tamarins and characterisation at discrete typing unit (DTU) level of 77 of these isolates. DTU TcII was found to exclusively infect primates, while TcI infected Didelphis aurita and lion tamarins. The majority of T. cruzi isolates derived from L. rosalia were shown to be TcII (33 out 42) Nine T. cruzi isolates displayed a TcI profile. Golden-headed lion tamarins demonstrated to be excellent reservoirs of TcII, as 24 of 26 T. cruzi isolates exhibited the TcII profile. We concluded the following: (i) the transmission cycle of T. cruzi in a same host species and forest fragment is modified over time, (ii) the infectivity competence of the golden lion tamarin population fluctuates in waves that peak every other year and (iii) both golden and golden-headed lion tamarins are able to maintain long-lasting infections by TcII and TcI. PMID:25946156

  12. [Screening with angiographic images prior to (99m)Tc-HMPAO labelled leukocyte scintigraphy in the diagnosis of periprosthetic infection].

    PubMed

    Granados, U; Fuster, D; Soriano, A; García, S; Bori, G; Martínez, J C; Mayoral, M; Perlaza, P; Tomás, X; Pons, F

    2015-01-01

    To evaluate the impact of the angioscintigrapy of the three phase bone scan as screening method to rule out infection of the hip and knee prosthesis prior to performing the (99m)Tc-HMPAO leukocyte scintigraphy. A total of 120 (70 women, 50 men; mean age 71±11years) with clinical suspicion of hip (n=63) or knee (n=57) infection of the prosthesis and clinical suspicion of infection were evaluated prospectively. All patients underwent three-phase bone scan (angioscintigraphy, vascular and bone phase) and (99m)Tc-HMPAO-labelled white blood cell scintigraphy. Final diagnosis of infection was made by microbiological documentation or clinical follow-up for at least 12months. Eighteen out of 120 patients were diagnosed of infection of hip prosthesis (n=10) or knee prosthesis (n=8). The angioscintigraphy was positive in 15/18 infected cases and in 21/102 of the non-infected cases with a sensitivity of 83%, specificity of 79% and negative predictive value of 97%. Sensitivity and specificity of (99m)Tc-HMPAO leukocyte scintigraphy were 72% and 95%, respectively. If the leukocyte labeled scintigraphies had been used exclusively for patients with positive angioscintigraphy, this would have saved up to 70% of the (99m)Tc-HMPAO leukocyte scintigraphies performed. There were no cases of infection with positive labeled leukocyte scintigraphy and negative angioscintigraphy. Angioscintigraphy (blood flow phase of bone scan) is a useful technique for screening for hip and knee joint prosthesis infection, significantly reducing the need for (99m)Tc-HMPAO leukocyte scintigraphy without affecting the sensitivity of the technique. Copyright © 2014 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  13. Multispectral Fluorescence Imaging During Robot-assisted Laparoscopic Sentinel Node Biopsy: A First Step Towards a Fluorescence-based Anatomic Roadmap.

    PubMed

    van den Berg, Nynke S; Buckle, Tessa; KleinJan, Gijs H; van der Poel, Henk G; van Leeuwen, Fijs W B

    2017-07-01

    During (robot-assisted) sentinel node (SN) biopsy procedures, intraoperative fluorescence imaging can be used to enhance radioguided SN excision. For this combined pre- and intraoperative SN identification was realized using the hybrid SN tracer, indocyanine green- 99m Tc-nanocolloid. Combining this dedicated SN tracer with a lymphangiographic tracer such as fluorescein may further enhance the accuracy of SN biopsy. Clinical evaluation of a multispectral fluorescence guided surgery approach using the dedicated SN tracer ICG- 99m Tc-nanocolloid, the lymphangiographic tracer fluorescein, and a commercially available fluorescence laparoscope. Pilot study in ten patients with prostate cancer. Following ICG- 99m Tc-nanocolloid administration and preoperative lymphoscintigraphy and single-photon emission computed tomograpy imaging, the number and location of SNs were determined. Fluorescein was injected intraprostatically immediately after the patient was anesthetized. A multispectral fluorescence laparoscope was used intraoperatively to identify both fluorescent signatures. Multispectral fluorescence imaging during robot-assisted radical prostatectomy with extended pelvic lymph node dissection and SN biopsy. (1) Number and location of preoperatively identified SNs. (2) Number and location of SNs intraoperatively identified via ICG- 99m Tc-nanocolloid imaging. (3) Rate of intraoperative lymphatic duct identification via fluorescein imaging. (4) Tumor status of excised (sentinel) lymph node(s). (5) Postoperative complications and follow-up. Near-infrared fluorescence imaging of ICG- 99m Tc-nanocolloid visualized 85.3% of the SNs. In 8/10 patients, fluorescein imaging allowed bright and accurate identification of lymphatic ducts, although higher background staining and tracer washout were observed. The main limitation is the small patient population. Our findings indicate that a lymphangiographic tracer can provide additional information during SN biopsy based on ICG- 99m

  14. Diagnostic value of 99mTc-ethambutol scintigraphy in tuberculosis: compared to microbiological and histopathological tests.

    PubMed

    Kartamihardja, A H S; Kurniawati, Y; Gunawan, R

    2018-01-01

    Tuberculosis (TB) still remains the world's endemic infection. TB affects the lungs and any part of the body other than the lung. The diagnosis of TB has not changed much over the decades. Ethambutol is one of the first line treatments for TB. It can be labeled using 99m Tc. 99m Tc-ethambutol will be accumulated in the site of TB lesion and can be imaged using gamma camera. The aim of this study was to evaluate the diagnostic value of 99m Tc-ethambutol scintigraphy in detecting and localizing of TB. Retrospective cross-sectional study was done. Subjects were patients suspected of having TB infection. Whole body and SPECT-CT imaging at the suspected area was done 1 and 4 h after injection of 370-555 MBq 99m Tc-ethambutol. 99m Tc-ethambutol scintigraphy was analyzed visually. The results were compared with that of histopathological or microbiological tests. Statistical analysis was done to determine the sensitivity, specificity, PPV, NPV and accuracy. One hundred and sixty-eight subjects were involved in this study. There were 110 men and 58 women with mean age of 34.52 ± 11.94 years. There were concordance results in 156 (92.86%) and discordant in 12 (7.14%) subjects between 99m Tc-ethambutol scintigraphy and histopathological or microbiological result. The sensitivity, specificity, PPV, NPV and accuracy of 99m Tc-ethambutol scintigraphy in the diagnosis of pulmonary TB were 93.9, 85.7, 93.9, 85.7 and 91.4%, respectively, for extra-pulmonary TB 95.5, 77.8, 97.9, 63.6, and 85.1%, respectively, and for total tuberculosis 94.9, 83.3, 96.3, 78.1 and 92.8%, respectively. There was no side effect observed in this study. 99m Tc-ethambutol scintigraphy is a useful diagnostic imaging technique to detect and localize intra- and extra-pulmonary TB. It is safe to be performed even in pediatric patient. Consuming ethambutol less than 2 weeks did not influence the result.

  15. Development of a Nondestructive Evaluation Technique for Degraded Thermal Barrier Coatings Using Microwave

    NASA Astrophysics Data System (ADS)

    Sayar, M.; Ogawa, K.; Shoji, T.

    2008-02-01

    Thermal barrier coatings have been widely used in gas turbine engines in order to protect substrate metal alloy against high temperature and to enhance turbine efficiency. Currently, there are no reliable nondestructive techniques available to monitor TBC integrity over lifetime of the coating. Hence, to detect top coating (TC) and TGO thicknesses, a microwave nondestructive technique that utilizes a rectangular waveguide was developed. The phase of the reflection coefficient at the interface of TC and waveguide varies for different TGO and TC thicknesses. Therefore, measuring the phase of the reflection coefficient enables us to accurately calculate these thicknesses. Finally, a theoretical analysis was used to evaluate the reliability of the experimental results.

  16. Halon-1301, a new Groundwater Age Tracer

    NASA Astrophysics Data System (ADS)

    Beyer, Monique; van der Raaij, Rob; Morgenstern, Uwe; Jackson, Bethanna

    2015-04-01

    Groundwater dating is an important tool to assess groundwater resources in regards to direction and time scale of groundwater flow and recharge and to assess contamination risks and manage remediation. To infer groundwater age information, a combination of different environmental tracers, such as tritium and SF6, are commonly used. However ambiguous age interpretations are often faced, due to a limited set of available tracers and limitations of each tracer method when applied alone. There is a need for additional, complementary groundwater age tracers. We recently discovered that Halon-1301, a water soluble and entirely anthropogenic gaseous substance, may be a promising candidate [Beyer et al, 2014]. Halon-1301 can be determined along with SF6, SF5CF3 and CFC-12 in groundwater using a gas chromatography setup with attached electron capture detector developed by Busenberg and Plummer [2008]. Halon-1301 has not been assessed in groundwater. This study assesses the behaviour of Halon-1301 in water and its suitability as a groundwater age tracer. We determined Halon-1301 in 17 groundwater and various modern (river) waters sites located in 3 different groundwater systems in the Wellington Region, New Zealand. These waters have been previously dated with tritium, CFC-12, CFC-11 and SF6 with mean residence times ranging from 0.5 to over 100 years. The waters range from oxic to anoxic and some show evidence of CFC contamination or degradation. This allows us to assess the different properties affecting the suitability of Halon-1301 as groundwater age tracer, such as its conservativeness in water and local contamination potential. The samples are analysed for Halon-1301 and SF6simultaneously, which allows identification of issues commonly faced when using gaseous tracers such as contamination with modern air during sampling. Overall we found in the assessed groundwater samples Halon-1301 is a feasible new groundwater tracer. No sample indicated significantly elevated

  17. Macrocyclic triamine derived glucose analogues for 99m Tc(CO)3 labeling: synthesis and biological evaluation as potential tumor-imaging agents.

    PubMed

    Liu, Teli; Gan, Qianqian; Zhang, Junbo

    2017-02-01

    [ 99m Tc(CO) 3 (H 2 O) 3 ] + has attracted great attention among 99m Tc-labeling techniques, due to its ease of preparation, readily substituted water molecules of the precursor fac-[ 99m Tc(CO) 3 (H 2 O) 3 ] + by a variety of functional groups, small size and inertness. Bifunctional chelator based on a macrocyclic polyamine framework shows easy complexation with [ 99m Tc(CO) 3 (H 2 O) 3 ] + to produce stable complex. In this study, two novel 1, 5, 9-triazacyclododecane derivatives containing a glucose group (6 and 7) were successfully synthesized by reacting different glucose-azides with alkyne-[12]aneN 3 via the so-called click chemistry and radiolabeled with [ 99m Tc(CO) 3 (H 2 O) 3 ] + to form 99m Tc(CO) 3 -6 (C-1-substituted complex) and 99m Tc(CO) 3 -7 (C-2-substituted complex) in high yields. The complexes were stable in vitro over 6 h when incubated in saline at room temperature and in mouse serum at 37 °C. The partition coefficient results showed that they were hydrophilic. The biodistribution studies in Kunming mice bearing S 180 tumor showed both complexes showed accumulation in the tumor. Between them, 99m Tc(CO) 3 -7 had the advantages of much higher tumor uptake and tumor/muscle ratio. Compared with other reported 99m Tc-radiolabeled glucose derivatives, 99m Tc(CO) 3 -7 also showed a higher tumor uptake and tumor/muscle ratio, suggesting it would be a potential candidate for further development as a tumor-imaging agent. © 2017 John Wiley & Sons A/S.

  18. Using High-Resolution Forward Model Simulations of Ideal Atmospheric Tracers to Assess the Spatial Information Content of Inverse CO2 Flux Estimates

    NASA Technical Reports Server (NTRS)

    Pawson, Steven; Nielsen, J. Eric

    2011-01-01

    Attribution of observed atmospheric carbon concentrations to emissions on the country, state or city level is often inferred using "inversion" techniques. Such computations are often performed using advanced mathematical techniques, such as synthesis inversion or four-dimensional variational analysis, that invoke tracing observed atmospheric concentrations backwards through a transport model to a source region. It is, to date, not well understood how well such techniques can represent fine spatial (and temporal) structure in the inverted flux fields. This question is addressed using forward-model computations with idealized tracers emitted at the surface in a large number of grid boxes over selected regions and examining how distinctly these emitted tracers can be detected downstream. Initial results show that tracers emitted in half-degree grid boxes over a large region of the Eastern USA cannot be distinguished from each other, even at short distances over the Atlantic Ocean, when they are emitted in grid boxes separated by less than five degrees of latitude - especially when only total-column observations are available. A large number of forward model simulations, with varying meteorological conditions, are used to assess how distinctly three types observations (total column, upper tropospheric column, and surface mixing ratio) can separate emissions from different sources. Inferences inverse modeling and source attribution will be drawn.

  19. A Rapid, Low-Cost Method to Determine Travel Times at Managed Aquifer Recharge Operations Using Noble Gas Tracers

    NASA Astrophysics Data System (ADS)

    Moran, J. E.; Visser, A.; Singleton, M. J.; Esser, B. K.; Halliwell, M.; Hillegonds, D. J.

    2012-12-01

    Managed aquifer recharge is a key component for the sustainable use of surface water and groundwater in the arid western U.S. When recycled water is a recharge water source, subsurface residence time, required for bacteria and virus deactivation, is best verified by application of an extrinsic tracer. Desirable tracer properties include: no real or perceived health risk, inexpensive even for a large volume of tagged water, large dynamic range, efficient introduction, convenient sampling methods, and rapid, low-cost analysis. We have developed and tested a dissolved noble gas tracer technique ideally suited for tracing large water volumes at managed aquifer recharge facilities. In an application of the method at a water district's facilities in the San Francisco Bay area, Xenon was introduced into a 106 m3 pond over a period of 7 days using a 300 m length of gas-permeable silicone tubing. Samples from the pond, near-field shallow monitoring wells, and production wells about 400 m from the recharge pond were analyzed for dissolved Xe by noble gas membrane inlet mass spectrometry (NGMIMS). The NGMIMS uses a syringe pump, gas-permeable membrane inlet, and quadrupole residual gas analyzer for measurement of noble gas concentrations. Samples are collected in VOA vials, and analysis can be carried out in real-time, with a measurement uncertainty of about 5% for Xe. Tracer first appeared in a production well 136 days after starting the tracer introduction at 0.7% (C/C0) of the peak pond xenon concentration. The cost of the tracer is about US650/106 m3 water, and the NGMIMS was assembled with parts totaling approximately US50,000, making application of the tracer method feasible for most managed aquifer recharge projects. This project is part of the California State Water Resources Control Board Groundwater Ambient Monitoring and Assessment (GAMA) Program.

  20. NEUTRON SCATTERING STUDY OF THE HIGH-Tc SUPERCONDUCTING SYSTEM YBa2Cu3O6+x

    NASA Astrophysics Data System (ADS)

    Rossat-Mignod, J.; Regnault, L. P.; Bourges, P.; Burlet, P.; Vettier, C.; Henry, J. Y.

    The following sections are included: * Introduction * The neutron scattering technique * Phase diagrams of high-Tc superconductors * The undoped AF-doped * The doped AF-state * The weakly-doped metallic state * The heavily-doped metallic state * The overdoped metallic state * Discussion and concluding remarks * Acknowledgements * References

  1. Bed load tracer mobility in a mixed bedrock/alluvial channel

    NASA Astrophysics Data System (ADS)

    Ferguson, R. I.; Sharma, B. P.; Hodge, R. A.; Hardy, R. J.; Warburton, J.

    2017-04-01

    The presence of bare or partially covered rock in an otherwise alluvial river implies a downstream change in transport capacity relative to supply. Field investigations of this change and what causes it are lacking. We used two sets of magnet-tagged tracer clasts to investigate bed load transport during the same sequence of floods in fully alluvial, bare rock, and partial-cover reaches of an upland stream. High-flow shear stresses in different reaches were calculated by using stage loggers. Tracers seeded in the upstream alluvial channel moved more slowly than elsewhere until the frontrunners reached bare rock and sped up. Tracers seeded on bare rock moved rapidly off it and accumulated just upstream from, and later in, a partial-cover zone with many boulders. The backwater effect of the boulder-rich zone is significant in reducing tracer mobility. Tracer movement over full or partial sediment cover was size selective but dispersion over bare rock was not. Along-channel changes in tracer mobility are interpreted in terms of measured differences in shear stress and estimated differences in threshold stress.

  2. Cosmological constraints from multiple tracers in spectroscopic surveys

    NASA Astrophysics Data System (ADS)

    Alarcon, Alex; Eriksen, Martin; Gaztanaga, Enrique

    2018-01-01

    We use the Fisher matrix formalism to study the expansion and growth history of the Universe using galaxy clustering with 2D angular cross-correlation tomography in spectroscopic or high-resolution photometric redshift surveys. The radial information is contained in the cross-correlations between narrow redshift bins. We show how multiple tracers with redshift space distortions cancel sample variance and arbitrarily improve the constraints on the dark energy equation of state ω(z) and the growth parameter γ in the noiseless limit. The improvement for multiple tracers quickly increases with the bias difference between the tracers, up to a factor ∼4 in FoMγω. We model a magnitude limited survey with realistic density and bias using a conditional luminosity function, finding a factor 1.3-9.0 improvement in FoMγω - depending on global density - with a split in a halo mass proxy. Partly overlapping redshift bins improve the constraints in multiple tracer surveys a factor ∼1.3 in FoMγω. This finding also applies to photometric surveys, where the effect of using multiple tracers is magnified. We also show large improvement on the FoM with increasing density, which could be used as a trade-off to compensate some possible loss with radial resolution.

  3. Performance Testing of Tracer Gas and Tracer Aerosol Detectors for use in Radionuclide NESHAP Compliance Testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fuehne, David Patrick; Lattin, Rebecca Renee

    The Rad-NESHAP program, part of the Air Quality Compliance team of LANL’s Compliance Programs group (EPC-CP), and the Radiation Instrumentation & Calibration team, part of the Radiation Protection Services group (RP-SVS), frequently partner on issues relating to characterizing air flow streams. This memo documents the most recent example of this partnership, involving performance testing of sulfur hexafluoride detectors for use in stack gas mixing tests. Additionally, members of the Rad-NESHAP program performed a functional trending test on a pair of optical particle counters, comparing results from a non-calibrated instrument to a calibrated instrument. Prior to commissioning a new stack samplingmore » system, the ANSI Standard for stack sampling requires that the stack sample location must meet several criteria, including uniformity of tracer gas and aerosol mixing in the air stream. For these mix tests, tracer media (sulfur hexafluoride gas or liquid oil aerosol particles) are injected into the stack air stream and the resulting air concentrations are measured across the plane of the stack at the proposed sampling location. The coefficient of variation of these media concentrations must be under 20% when evaluated over the central 2/3 area of the stack or duct. The instruments which measure these air concentrations must be tested prior to the stack tests in order to ensure their linear response to varying air concentrations of either tracer gas or tracer aerosol. The instruments used in tracer gas and aerosol mix testing cannot be calibrated by the LANL Standards and Calibration Laboratory, so they would normally be sent off-site for factory calibration by the vendor. Operational requirements can prevent formal factory calibration of some instruments after they have been used in hazardous settings, e.g., within a radiological facility with potential airborne contamination. The performance tests described in this document are intended to demonstrate the

  4. Identification and characterization of conservative organic tracers for use as hydrologic tracers for the Yucca Mountain site characterization study. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stetzenbach, K.; Farnham, I.

    1996-06-01

    Extensive tracer testing is expected to take place at the C-well complex in the Nevada Test Site as part of the Yucca Mountain Site Characterization Project. The C-well complex consists of one pumping well, C3, and two injection wells, C1 and C2 into which tracer will be introduced. The goal of this research was to provide USGS with numerous tracers to completed these tests. Several classes of fluorinated organic acids have been evaluated. These include numerous isomers of fluorinated benzoic acids, cinnamic acids, and salicylic acids. Also several derivatives of 2-hydroxy nicotinic acid (pyridone) have been tested. The stability ofmore » these compounds was determined using batch and column tests. Ames testing (mutagenicity/carcinogenicity) was conducted on the fluorinated benzoic acids and a literature review of toxicity of the fluorobenzoates and three perfluoro aliphatic acids was prepared. Solubilities were measured and method development work was performed to optimize the detection of these compounds. A Quality Assurance (QA) Program was developed under existing DOE and USGS guidelines. The program includes QA procedures and technical standard operating procedures. A tracer test, using sodium iodide, was performed at the C-well complex. HRC chemists performed analyses on site, to provide real time data for the USGS hydrologists and in the laboratories at UNLV. Over 2,500 analyses were performed. This report provides the results of the laboratory experiments and literature reviews used to evaluate the potential tracers and reports on the results of the iodide C-well tracer test.« less

  5. Spatiotemporal distribution modeling of PET tracer uptake in solid tumors.

    PubMed

    Soltani, Madjid; Sefidgar, Mostafa; Bazmara, Hossein; Casey, Michael E; Subramaniam, Rathan M; Wahl, Richard L; Rahmim, Arman

    2017-02-01

    Distribution of PET tracer uptake is elaborately modeled via a general equation used for solute transport modeling. This model can be used to incorporate various transport parameters of a solid tumor such as hydraulic conductivity of the microvessel wall, transvascular permeability as well as interstitial space parameters. This is especially significant because tracer delivery and drug delivery to solid tumors are determined by similar underlying tumor transport phenomena, and quantifying the former can enable enhanced prediction of the latter. We focused on the commonly utilized FDG PET tracer. First, based on a mathematical model of angiogenesis, the capillary network of a solid tumor and normal tissues around it were generated. The coupling mathematical method, which simultaneously solves for blood flow in the capillary network as well as fluid flow in the interstitium, is used to calculate pressure and velocity distributions. Subsequently, a comprehensive spatiotemporal distribution model (SDM) is applied to accurately model distribution of PET tracer uptake, specifically FDG in this work, within solid tumors. The different transport mechanisms, namely convention and diffusion from vessel to tissue and in tissue, are elaborately calculated across the domain of interest and effect of each parameter on tracer distribution is investigated. The results show the convection terms to have negligible effect on tracer transport and the SDM can be solved after eliminating these terms. The proposed framework of spatiotemporal modeling for PET tracers can be utilized to comprehensively assess the impact of various parameters on the spatiotemporal distribution of PET tracers.

  6. APOA5 -1131T>C and APOC3 -455T>C polymorphisms are associated with an increased risk of coronary heart disease.

    PubMed

    Sun, Y; Zhou, R B; Chen, D M

    2015-12-28

    The aim of this study was to investigate correlations between apolipoprotein A-V (APOA5) -1131T>C and apolipoprotein C-III (APOC3) -455T>C polymorphisms and coronary heart disease (CHD). PubMed, Ovid, Cochrane Library, Embase, China National Knowledge Infrastructure, and Wanfang databases were searched using combinations of keywords relating to these polymorphisms and CHD. Studies retrieved from database searches were screened using our stringent inclusion and exclusion criteria, and Comprehensive Meta-Analysis Version 2.0 software was used for statistical analyses. In total, 115 studies were initially retrieved and after further selection, 11 were included in the meta-analysis. These 11 articles comprised 4840 patients with CHD in the case group and 4913 healthy participants in the control group. Meta-analysis revealed that APOA5 -1131T>C and APOC3 -455T>C polymorphisms increased CHD risk. In addition, subgroup analysis by ethnicity showed that while the -1131T>C polymorphism elevated the risk of CHD in the Caucasian population under both allelic and dominant models, this increased risk was observed only under a dominant model in the Asian population. The results of our meta-analysis point to a strong link between both APOA5 -1131T>C and APOC3 -455T>C polymorphisms and an increased risk of CHD. Thus, these polymorphisms constitute important predictive indicators of CHD susceptibility.

  7. TRACERS FORECAST THE PERFORMANCE OF NAPL REMEDIATION PROJECTS

    EPA Science Inventory

    Organic tracers which partition to residual NAPL contamination have been used to estimate the mass of contamination in the swept zone of the tracer. This paper expands on this approach using the same data to estimate the heterogeneity of the flow domain and the heterogeneity of ...

  8. 77 FR 54908 - TC Offshore, LLC; Notice Establishing Deadline for Comments

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-06

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. RP12-908-000] TC Offshore, LLC; Notice Establishing Deadline for Comments On August 29, 2012, TC Offshore, LLC (TC Offshore... is hereby given that participants in the captioned proceedings may file comments to TC Offshsore's...

  9. Radiochemical studies of 99mTc complexes of modified cysteine ligands and bifunctional chelating agents.

    PubMed

    Pillai, M R; Kothari, K; Banerjee, S; Samuel, G; Suresh, M; Sarma, H D; Jurisson, S

    1999-07-01

    The synthesis of four novel ligands using the amino-acid cysteine and its ethyl carboxylate derivative is described. The synthetic method involves a two-step procedure, wherein the intermediate Schiff base formed by the condensation of the amino group of the cysteine substrate and salicylaldehyde is reduced to give the target ligands. The intermediates and the final products were characterized by high resolution nuclear magnetic resonance spectroscopy. Complexation studies of the ligands with 99mTc were optimized using stannous tartrate as the reducing agent under varying reaction conditions. The complexes were characterized using standard quality control techniques such as thin layer chromatography, paper electrophoresis, and paper chromatography. Lipophilicities of the complexes were estimated by solvent extraction into chloroform. Substantial changes in net charge and lipophilicity of the 99mTc complexes were observed on substituting the carboxylic acid functionality in ligands I and II with the ethyl carboxylate groups (ligands II and IV). All the ligands formed 99mTc complexes in high yield. Whereas the complexes with ligands I and II were observed to be hydrophilic in nature and not extractable into CHCl3, ligands III and IV resulted in neutral and lipophilic 99mTc complexes. The 99mTc complex with ligand II was not stable and on storage formed a hydrophilic and nonextractable species. The biodistribution of the complexes of ligands I and II showed that they cleared predominantly through the kidneys, whereas the complexes with ligands III and IV were excreted primarily through the hepatobiliary system. No significant brain uptake was observed with the 99mTc complexes with ligands III and IV despite their favorable properties of neutrality, lipophilicity, and conversion into a hydrophilic species. These ligands offer potential for use as bifunctional chelating agents.

  10. A Lagrangian particle method with remeshing for tracer transport on the sphere

    DOE PAGES

    Bosler, Peter Andrew; Kent, James; Krasny, Robert; ...

    2017-03-30

    A Lagrangian particle method (called LPM) based on the flow map is presented for tracer transport on the sphere. The particles carry tracer values and are located at the centers and vertices of triangular Lagrangian panels. Remeshing is applied to control particle disorder and two schemes are compared, one using direct tracer interpolation and another using inverse flow map interpolation with sampling of the initial tracer density. Test cases include a moving-vortices flow and reversing-deformational flow with both zero and nonzero divergence, as well as smooth and discontinuous tracers. We examine the accuracy of the computed tracer density and tracermore » integral, and preservation of nonlinear correlation in a pair of tracers. Here, we compare results obtained using LPM and the Lin–Rood finite-volume scheme. An adaptive particle/panel refinement scheme is demonstrated.« less

  11. A Lagrangian particle method with remeshing for tracer transport on the sphere

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bosler, Peter Andrew; Kent, James; Krasny, Robert

    A Lagrangian particle method (called LPM) based on the flow map is presented for tracer transport on the sphere. The particles carry tracer values and are located at the centers and vertices of triangular Lagrangian panels. Remeshing is applied to control particle disorder and two schemes are compared, one using direct tracer interpolation and another using inverse flow map interpolation with sampling of the initial tracer density. Test cases include a moving-vortices flow and reversing-deformational flow with both zero and nonzero divergence, as well as smooth and discontinuous tracers. We examine the accuracy of the computed tracer density and tracermore » integral, and preservation of nonlinear correlation in a pair of tracers. Here, we compare results obtained using LPM and the Lin–Rood finite-volume scheme. An adaptive particle/panel refinement scheme is demonstrated.« less

  12. A Simple and Inexpensive Technique for Assessing Microbial Contamination during Drilling Operations

    NASA Astrophysics Data System (ADS)

    Friese, A.; Kallmeyer, J.; Wagner, D.; Kitte, J. A.

    2016-12-01

    Exploration of the Deep Biosphere relies on drilling, which inevitably causes infiltration of drilling fluids, containing non-indigenous microbes from the surface, into the core. Therefore it is absolutely necessary to trace contamination of the sediment core in order to identify uncontaminated samples for microbiological investigations in drill core samples. To do this, usually a tracer is mixed into the drilling fluid. In past drilling operations a variety of tracers have been used including dyes, salts, dissolved gasses, and microspheres. The latter are microbe-sized fluorescent particles that can be detected with very high sensitivity. Each tracer has its specific strengths and weaknesses, for microspheres the main problem was the high price, which limited the use to spot checks or drilling operations that require only small amounts of drilling fluid. Here, we present a modified microsphere tracer approach, using an aqueous fluorescent pigment dispersion that has a similar concentration of fluorescent particles as previously used microsphere tracers. However, compared to previous microsphere tracers, the cost of the new tracer is four orders of magnitude lower, allowing for a much more liberal use even in large-scale operations. Its suitability for large drilling campaigns was successfully tested at the ICDP Deep Drilling at Lake Towuti, Sulawesi, Indonesia and at the ICDP Deep Drilling at Lake Chalco, Mexico. Contamination can be detected by fluorescence microscopy or by flow cytometry at a sensitivity that is in the range of established techniques. Quantification of the tracer thus only requires a minimum of equipment and by using a small portable cytometer, high-resolution data can be obtained directly on-site within minutes and with minimal effort. Therefore this approach offers an inexpensive but powerful alternative technique for contamination assessment for future drilling campaigns.

  13. 75 FR 5855 - Proposed Collection; Comment Request for Form 8038-TC

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-04

    ... 8038-TC AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Notice and request for comments... comments concerning Form 8038-TC, Information Return for Tax Credit Bonds. DATES: Written comments should...: Form 8038-TC. Abstract: Form 8038-TC will be used by issuers of qualified tax- exempt credit bonds...

  14. Tc-99m Labeled carrier for imaging

    DOEpatents

    Henze, Eberhard

    1984-01-01

    Novel radionuclide imaging agents, having particular application for lymphangiography are provided by non-covalently binding Tc-99m to a pharmaceutically acceptable cross-linked polysaccharide. Upon injection of the Tc-99m labeled polysaccharide into the blood stream, optimum contrast can be obtained within one hour.

  15. Comparison of 99mTc-TRODAT-1 SPECT and 18 F-AV-133 PET imaging in healthy controls and Parkinson's disease patients.

    PubMed

    Hsiao, Ing-Tsung; Weng, Yi-Hsin; Lin, Wey-Yil; Hsieh, Chia-Ju; Wey, Shiaw-Pyng; Yen, Tzu-Chen; Kung, Mei-Ping; Lu, Chin-Song; Lin, Kun-Ju

    2014-04-01

    characteristics than that of (99m)Tc-TRODAT-1 SPECT. (18)F-AV-133 PET also showed additional information in substantia nigra integrity in PD subjects by voxelwise analysis. Collectively, (18)F-AV-133 could be a promising and better tracer for clinical use to detect monoaminergic terminal reduction in PD patients. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Assessing the Accuracy of the Tracer Dilution Method with Atmospheric Dispersion Modeling

    NASA Astrophysics Data System (ADS)

    Taylor, D.; Delkash, M.; Chow, F. K.; Imhoff, P. T.

    2015-12-01

    Landfill methane emissions are difficult to estimate due to limited observations and data uncertainty. The mobile tracer dilution method is a widely used and cost-effective approach for predicting landfill methane emissions. The method uses a tracer gas released on the surface of the landfill and measures the concentrations of both methane and the tracer gas downwind. Mobile measurements are conducted with a gas analyzer mounted on a vehicle to capture transects of both gas plumes. The idea behind the method is that if the measurements are performed far enough downwind, the methane plume from the large area source of the landfill and the tracer plume from a small number of point sources will be sufficiently well-mixed to behave similarly, and the ratio between the concentrations will be a good estimate of the ratio between the two emissions rates. The mobile tracer dilution method is sensitive to different factors of the setup such as placement of the tracer release locations and distance from the landfill to the downwind measurements, which have not been thoroughly examined. In this study, numerical modeling is used as an alternative to field measurements to study the sensitivity of the tracer dilution method and provide estimates of measurement accuracy. Using topography and wind conditions for an actual landfill, a landfill emissions rate is prescribed in the model and compared against the emissions rate predicted by application of the tracer dilution method. Two different methane emissions scenarios are simulated: homogeneous emissions over the entire surface of the landfill, and heterogeneous emissions with a hot spot containing 80% of the total emissions where the daily cover area is located. Numerical modeling of the tracer dilution method is a useful tool for evaluating the method without having the expense and labor commitment of multiple field campaigns. Factors tested include number of tracers, distance between tracers, distance from landfill to transect

  17. 78 FR 40824 - Proposed Collection; Comment Request for Form 8038-TC

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-08

    ... 8038-TC AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Notice and request for comments... Form 8038-TC, Information Return for Tax Credit Bonds. DATES: Written comments should be received on or...-TC. Abstract: Form 8038-TC will be used by issuers of qualified tax- exempt credit bonds, including...

  18. Labeling and Biological Evaluation of (99m)Tc-HYNIC-Trastuzumab as a Potential Radiopharmaceutical for In Vivo Evaluation of HER2 Expression in Breast Cancer.

    PubMed

    Calzada, Victoria; Garcia, Fernanda; Fernández, Marcelo; Porcal, Williams; Quinn, Thomas; Alonso, Omar; Gambini, Juan Pablo; Cabral, Pablo

    2013-01-01

    The amplification of HER2 gene has been described in several tumor types, mainly breast cancer with a subsequent increase in HER2 protein expression. Trastuzumab is a humanized monoclonal antibody that recognizes selectively the HER2 extracellular domain. The objective of the present work was to standardize the conjugation of Trastuzumab with Succinimidyl-hydrazinonicotinamide (HYNIC) and labeling with (99m)Tc to obtain (99m)Tc-HYNIC-Trastuzumab for use as in vivo tracer of the HER2 expression in breast cancer. The labeling procedure involved derivatization of 0.067 μmol of Trastuzumab with 0.33 μmols of HYNIC in dimethyl sulfoxide (DMSO). The mixture was incubated for 30 min. A mixture of Tricine and SnCl2.2H2O was prepared by add a solution of 44.6 μmols Tricine in 0.05 mL HCl 2.0 M and a similar volume of another solution containing 44.3 μmols SnCl2.2H2O in 0.5 mL HCl 2.0 M. Then, 0.05 mL of this mixed was added to the conjugated with 296 MBq of 99mTcO-4. The final mixture was incubated at room temperature (18-25°C) for 30 min. Radiochemical purity of the labeled solution was studied by chromatography, to evaluate (99m)Tc-Tricine, (99m)TcO2.H2O, and free (99m)TcO4 (-). Radiochemical purity was also evaluated by HPLC. Stability studies were tested in solution at 4°C and lyophilized at 4°C. Biodistribution studies were performed in healthy CD-1 female mice at 2, 5, and 24 h (n = 3) and CD-1 female mice spontaneous breast adenocarcinoma (n = 3). Scintigraphic images of spontaneous breast adenocarcinoma in female CD-1 mice were acquired in a gamma camera at 2, 5, and 24 h post-injection. Labeling was easily performed with high yields (>90%) and radiopharmaceutical stability for 24 h post-labeling. Stability studies revealed that antibody derivative must be lyophilized for undamaged storage. Biodistribution studies and imaging revealed excellent uptake in the tumor. Based on the results it was concluded that (99m)Tc-HYNIC-Trastuzumab could be a promising

  19. Analysis of speckle and material properties in laider tracer

    NASA Astrophysics Data System (ADS)

    Ross, Jacob W.; Rigling, Brian D.; Watson, Edward A.

    2017-04-01

    The SAL simulation tool Laider Tracer models speckle: the random variation in intensity of an incident light beam across a rough surface. Within Laider Tracer, the speckle field is modeled as a 2-D array of jointly Gaussian random variables projected via ray tracing onto the scene of interest. Originally, all materials in Laider Tracer were treated as ideal diffuse scatterers, for which the far-field return computed uses the Lambertian Bidirectional Reflectance Distribution Function (BRDF). As presented here, we implement material properties into Laider Tracer via the Non-conventional Exploitation Factors Data System: a database of properties for thousands of different materials sampled at various wavelengths and incident angles. We verify the intensity behavior as a function of incident angle after material properties are added to the simulation.

  20. Quantifying solute transport processes: are chemically "conservative" tracers electrically conservative?

    USGS Publications Warehouse

    Singha, Kamini; Li, Li; Day-Lewis, Frederick D.; Regberg, Aaron B.

    2012-01-01

    The concept of a nonreactive or conservative tracer, commonly invoked in investigations of solute transport, requires additional study in the context of electrical geophysical monitoring. Tracers that are commonly considered conservative may undergo reactive processes, such as ion exchange, thus changing the aqueous composition of the system. As a result, the measured electrical conductivity may reflect not only solute transport but also reactive processes. We have evaluated the impacts of ion exchange reactions, rate-limited mass transfer, and surface conduction on quantifying tracer mass, mean arrival time, and temporal variance in laboratory-scale column experiments. Numerical examples showed that (1) ion exchange can lead to resistivity-estimated tracer mass, velocity, and dispersivity that may be inaccurate; (2) mass transfer leads to an overestimate in the mobile tracer mass and an underestimate in velocity when using electrical methods; and (3) surface conductance does not notably affect estimated moments when high-concentration tracers are used, although this phenomenon may be important at low concentrations or in sediments with high and/or spatially variable cation-exchange capacity. In all cases, colocated groundwater concentration measurements are of high importance for interpreting geophysical data with respect to the controlling transport processes of interest.

  1. Simultaneous Tc-99m skeletal and In-111 hip arthrographic scintimaging complementing contrast radiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wellman, H.N.; Uri, B.G.; Stiner, P.

    1984-01-01

    Prosthetic hip replacement has become a frequent procedure with femoral component (FC) loosening occurring frequently at a rate of 24% at 7 yrs post arthroplasty. Pain may occur from a variety of causes and identification of loosening as the cause is critical. Experience with radiographic contrast arthrography (XA) alone has often resulted in equivocal studies because of confusion caused by the radio-opaque glue-bone interface and adjacent radiolucency of the FC. Radionuclide arthrography (RA) with Tc-99m Sulfur Colloid (SC) has been previously shown to improve the efficiency of FC loosening determination. However, with extravasation or other confusing patterns of tracer distributionmore » more precise localization relative to skeletal structure is required with RA. Simultaneous use of RA using In-111 (IN) chloride (0.2 mCi) injected with contrast at XA superimposed on prior injected TC-99m MDP (20 mCi) skeletal imaging (SI) has considerably improved interpretation and complemented XA, correlated with surgery. Fifty RA and XA patients have been studied: 18 with SC alone, 7 with SC and IN in the joint space simultaneously and 25 with IN RA and SI. Simultaneous joint injection RA with IN and SC demonstrated exactly the same pattern with no translocation of IN. Thirty patients had surgery with 20 loose FC verified; all loose by RA but only 16 by XA plus 2 false positives. Also simultaneous SI has shown unreliable criteria for FC loosening. Thus, addition of simultaneous RA and SI for FC evaluation is a valuable adjunct in 20% of patients in the performance of arthrography.« less

  2. Modified expression for bulb-tracer depletion—Effect on argon dating standards

    USGS Publications Warehouse

    Fleck, Robert J.; Calvert, Andrew T.

    2014-01-01

    40Ar/39Ar geochronology depends critically on well-calibrated standards, often traceable to first-principles K-Ar age calibrations using bulb-tracer systems. Tracer systems also provide precise standards for noble-gas studies and interlaboratory calibration. The exponential expression long used for calculating isotope tracer concentrations in K-Ar age dating and calibration of 40Ar/39Ar age standards may provide a close approximation of those values, but is not correct. Appropriate equations are derived that accurately describe the depletion of tracer reservoirs and concentrations of sequential tracers. In the modified expression the depletion constant is not in the exponent, which only varies as integers by tracer-number. Evaluation of the expressions demonstrates that systematic error introduced through use of the original expression may be substantial where reservoir volumes are small and resulting depletion constants are large. Traditional use of large reservoir to tracer volumes and the resulting small depletion constants have kept errors well less than experimental uncertainties in most previous K-Ar and calibration studies. Use of the proper expression, however, permits use of volumes appropriate to the problems addressed.

  3. Tc-99m Glu-Cys-Gly-His-Gly-Lys (ECG-HGK), a novel Tc-99m labeled hexapeptide for molecular tumor imaging.

    PubMed

    Kim, Dae-Weung; Kim, Myoung Hyoun; Kim, Chang Guhn

    2016-03-01

    Domain 5 of kinin-free high molecular weight kininogen inhibits the adhesion of many tumor cell lines, and it has been reported that the histidine-glycine-lysine (HGK)-rich region might be responsible for inhibition of cell adhesion. The authors developed HGK-containing hexapeptide, glutamic acid-cysteine-glycine (ECG)-HGK, and evaluated the utility of Tc-99m ECG-HGK for tumor imaging. Hexapeptide, ECG-HGK was synthesized using Fmoc solid-phase peptide synthesis. Radiolabeling efficiency was evaluated. The uptake of Tc-99m ECG-HGK within HT-1080 cells was evaluated in vitro. In HT-1080 tumor-bearing mice, gamma imaging and biodistribution studies were performed. The complexes Tc-99m ECG-HGK was prepared in high yield. The uptake of Tc-99m ECG-HGK within the HT-1080 tumor cells had been demonstrated by in vitro studies. The gamma camera imaging in the murine model showed that Tc-99m ECG-HGK was accumulated substantially in the HT-1080 tumor (tumor-to-muscle ratio = 5.7 ± 1.4 at 4 h), and the tumoral uptake was blocked by the co-injection of excess HGK (tumor-to-muscle ratio = 2.8 ± 0.6 at 4 h). In the present study, Tc-99m ECG-HGK was developed as a new tumor imaging agents. Our in vitro and in vivo studies revealed specific function of Tc-99m ECG-HGK for tumor imaging. Copyright © 2016 John Wiley & Sons, Ltd.

  4. PREFACE: 2013 Joint IMEKO (International Measurement Confederation) TC1-TC7-TC13 Symposium: Measurement Across Physical and Behavioural Sciences

    NASA Astrophysics Data System (ADS)

    Battista Rossi, Giovanni; Crenna, Francesco; Belotti, Vittorio

    2013-09-01

    The 2013 Joint IMEKO (International Measurement Confederation) TC1-C7-TC13 was organised by the University of Genova - DIME/MEC, Measurement Laboratory, Italy, on 4-6 September 2013. The work of this symposium is reported in this volume. The scope of the symposium includes the main topics covered by the above Technical Committees: TC1 Education and Training in Measurement and Instrumentation TC7 Measurement Science TC13 Measurements in Biology and Medicine This is in keeping with the tradition set by the previous events of this well established series. There has been a special focus on measurement across physical and behavioural sciences, with the aim of highlighting the interdisciplinary character of measurement science and of promoting constructive interactions with scientists in other disciplines. The discussion was introduced by keynote lectures on measurement challenges in psychophysics, psychometrics and quantum physics. The symposium was attended by experts working in these areas from 18 countries, including USA, Australia and Japan, and provided a useful forum for them to share and exchange their work and ideas. In total over sixty papers are included in the volume, organised according to the presentation sessions. Each paper was independently peer-reviewed by two reviewers from a distinguished international panel. The Symposium was held in Genova, which was the European Capital of Culture in 2004, and took place in Palazzo Ducale, an important historical building whose construction started in the 13th century, and that has been the house of the Duke of Genova from the 14th century. Genova, whose name comes from the Latin word 'Janua' (meaning 'door', as January is the door month of the year), has been regarded over the centuries as a door connecting Europe with the different countries and cultures of the Mediterranean basin and thus was an appropriate site for an international symposium involving different and new scientific visions and approaches to

  5. SCDFT Study of High Tc Nitride Superconductors

    NASA Astrophysics Data System (ADS)

    Arita, R.

    Based on the density functional theory for superconductors (SCDFT), we study the pairing mechanism of the layered nitride superconductors, β-LixMNCl (M=Zr, Hf). Recently, it has been shown that SCDFT reproduces experimental superconducting transition temperatures (Tc) of conventional superconductors very accurately. Here we use SCDFT as a "litmus paper" to determine whether the system is a conventional or unconventional superconductor. We show that Tc estimated by SCDFT is less than half of the experimental Tc and its doping dependence is opposite to that observed in the experiments. The present result suggests that β- LixMNCl is not a Migdal-Eliashberg type superconductor.

  6. TcCYPR04, a Cacao Papain-Like Cysteine-Protease Detected in Senescent and Necrotic Tissues Interacts with a Cystatin TcCYS4

    PubMed Central

    Cardoso, Thyago Hermylly Santana; Freitas, Ana Camila Oliveira; Andrade, Bruno Silva; de Sousa, Aurizangela Oliveira; Santiago, André da Silva; Koop, Daniela Martins; Gramacho, Karina Peres; Alvim, Fátima Cerqueira; Micheli, Fabienne; Pirovani, Carlos Priminho

    2015-01-01

    The interaction amongst papain-like cysteine-proteases (PLCP) and their substrates and inhibitors, such as cystatins, can be perceived as part of the molecular battlefield in plant-pathogen interaction. In cacao, four cystatins were identified and characterized by our group. We identified 448 proteases in cacao genome, whereof 134 were cysteine-proteases. We expressed in Escherichia coli a PLCP from cacao, named TcCYSPR04. Immunoblottings with anti-TcCYSPR04 exhibited protein increases during leaf development. Additional isoforms of TcCYSPR04 appeared in senescent leaves and cacao tissues infected by Moniliophthora perniciosa during the transition from the biotrophic to the saprophytic phase. TcCYSPR04 was induced in the apoplastic fluid of Catongo and TSH1188 cacao genotypes, susceptible and resistant to M. perniciosa, respectively, but greater intensity and additional isoforms were observed in TSH1188. The fungal protein MpNEP induced PLCP isoform expression in tobacco leaves, according to the cross reaction with anti-TcCYSPR04. Several protein isoforms were detected at 72 hours after treatment with MpNEP. We captured an active PLCP from cacao tissues, using a recombinant cacao cystatin immobilized in CNBr-Sepharose. Mass spectrometry showed that this protein corresponds to TcCYSPR04. A homology modeling was obtained for both proteins. In order to become active, TcCYSPR04 needs to lose its inhibitory domain. Molecular docking showed the physical-chemical complementarities of the interaction between the cacao enzyme and its inhibitor. We propose that TcCYSPR04 and its interactions with cacao cystatins are involved in the senescence and necrosis events related to witches’ broom symptoms. This molecular interaction may be the target for future interventions to control witches' broom disease. PMID:26641247

  7. TcCYPR04, a Cacao Papain-Like Cysteine-Protease Detected in Senescent and Necrotic Tissues Interacts with a Cystatin TcCYS4.

    PubMed

    Cardoso, Thyago Hermylly Santana; Freitas, Ana Camila Oliveira; Andrade, Bruno Silva; Sousa, Aurizangela Oliveira de; Santiago, André da Silva; Koop, Daniela Martins; Gramacho, Karina Peres; Alvim, Fátima Cerqueira; Micheli, Fabienne; Pirovani, Carlos Priminho

    2015-01-01

    The interaction amongst papain-like cysteine-proteases (PLCP) and their substrates and inhibitors, such as cystatins, can be perceived as part of the molecular battlefield in plant-pathogen interaction. In cacao, four cystatins were identified and characterized by our group. We identified 448 proteases in cacao genome, whereof 134 were cysteine-proteases. We expressed in Escherichia coli a PLCP from cacao, named TcCYSPR04. Immunoblottings with anti-TcCYSPR04 exhibited protein increases during leaf development. Additional isoforms of TcCYSPR04 appeared in senescent leaves and cacao tissues infected by Moniliophthora perniciosa during the transition from the biotrophic to the saprophytic phase. TcCYSPR04 was induced in the apoplastic fluid of Catongo and TSH1188 cacao genotypes, susceptible and resistant to M. perniciosa, respectively, but greater intensity and additional isoforms were observed in TSH1188. The fungal protein MpNEP induced PLCP isoform expression in tobacco leaves, according to the cross reaction with anti-TcCYSPR04. Several protein isoforms were detected at 72 hours after treatment with MpNEP. We captured an active PLCP from cacao tissues, using a recombinant cacao cystatin immobilized in CNBr-Sepharose. Mass spectrometry showed that this protein corresponds to TcCYSPR04. A homology modeling was obtained for both proteins. In order to become active, TcCYSPR04 needs to lose its inhibitory domain. Molecular docking showed the physical-chemical complementarities of the interaction between the cacao enzyme and its inhibitor. We propose that TcCYSPR04 and its interactions with cacao cystatins are involved in the senescence and necrosis events related to witches' broom symptoms. This molecular interaction may be the target for future interventions to control witches' broom disease.

  8. Transport of Passive Tracers in Baroclinic Wave Life Cycles

    NASA Technical Reports Server (NTRS)

    Stone, Elizabeth M.; Randel, William J.; Stanford, John L.

    1999-01-01

    The transport of passive tracers in idealized baroclinic wave life cycles is studied using output from the National Center for Atmospheric Research Community Climate Model (CCM2). Two life cycles, LCn and LCs, are simulated, starting with baroclinically unstable initial conditions similar to those used by Thorncroft et al. in their study of two life cycle paradigms. The two life cycles LCn and LCs have different initial horizontal wind shear structures that result in distinctive nonlinear development. In terms of potential vorticity-potential temperature (PV-theta) diagnostics, the LCn case is characterized by thinning troughs that are advected anti-cyclonically and equatorward, while the LCs case has broadening troughs that wrap up cyclonically and poleward. Four idealized passive tracers are included in the model to be advected by the semi-Lagrangian transport scheme of the CCM2, and their evolutions are investigated throughout the life cycles. Tracer budgets are analyzed in terms of the transformed Eulerian mean constituent transport formalism in pressure coordinates and also in isentropic coordinates. Results for both LCn and LCs show transport that is downgradient with respect to the background structure of the tracer field, but with a characteristic spatial structure that maximizes in the middle to high latitudes. For the idealized tropospheric tracers in this study, this represents a net upward and poleward transport that enhances concentrations at high latitudes. These results vary little with the initial distribution of the constituent field. The time tendency of the tracer is influenced most strongly by the eddy flux term. with the largest transport occurring during the nonlinear growth stage of the life cycle. The authors also study the transport of a lower-stratospheric tracer, to examine stratosphere-troposphere exchange for baroclinic waves.

  9. Validation of an ergonomic method to withdraw [99mTc] radiopharmaceuticals.

    PubMed

    Blondeel-Gomes, Sandy; Marie, Solène; Fouque, Julien; Loyeau, Sabrina; Madar, Olivier; Lokiec, François

    2017-11-10

    The main objective of the present work was to ensure quality of radiopharmaceuticals syringes withdrawn with a "Spinal needle/obturator In-Stopper" system. Methods: Visual examinations and physicochemical tests are performed at T0 and T+4h for [ 99m Tc]albumin nanocolloid and T+7h for [ 99m Tc]eluate, [ 99m Tc] HydroxyMethylene DiPhosphonate and [ 99m Tc]Human Serum Albumin. Microbiological validation was performed according to European pharmacopoeia. Fingertip radiation exposure was evaluated to confirm the safety of the system. Results: Results show stable visual and physicochemical properties. The integrity of the connector was not affected after 30 punctures (no cores). No microbiological contamination was found on tested syringes. Conclusion: The system could be used 30 times. The stability of syringes drawing with this method is guaranteed up to 4 hours for [ 99m Tc]albumin nanocolloid and 7 hours for [ 99m Tc]eluate, [ 99m Tc]HydroxyMethylene DisPhosphonate and [ 99m Tc]Human serum albumin. Copyright © 2017 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  10. Novel S-35 Intrinsic Tracer Method for Determining Groundwater Travel Time near Managed Aquifer Recharge Facilities

    NASA Astrophysics Data System (ADS)

    Urióstegui, S. H.; Bibby, R. K.; Esser, B. K.; Clark, J. F.

    2013-12-01

    Identifying groundwater travel times near managed aquifer recharge (MAR) facilities is a high priority for protecting public and environmental health. For MAR facilities in California that incorporate tertiary wastewater into their surface-spreading recharge practices, the target subsurface residence time is >9 months to allow for the natural inactivation and degradation of potential contaminants (less time is needed for full advanced treated water). Established intrinsic groundwater tracer techniques such as tritium/helium-3 dating are unable to resolve timescales of <1 year. These limitations provide the motivation for evaluating a novel groundwater tracer method using a naturally occurring radioisotope of sulfur, sulfur-35 (S-35). After its production in the atmosphere by cosmic ray interaction with argon, S-35 enters the hydrologic cycle as dissolved sulfate through precipitation The short half-life of S-35 (3 months) is ideal for investigating recharge and transport of MAR groundwater on the <1 year timescale of interest to MAR managers. The method, however, has not been applied to MAR operations because of the difficulty in measuring S-35 with sufficient sensitivity in high-sulfate waters. We have developed a new method and have applied it at two southern California MAR facilities where groundwater travel times have previously been characterized using deliberate tracers: 1) Rio Hondo Spreading Grounds in Los Angeles County, and 2) Orange County Groundwater Recharge Facilities in Orange County. Reasonable S-35 travel times of <1 year were identified at both study sites. This method also identified seasonal patterns in subsurface travel times, which may not be revealed by a deliberate tracer study that is dependent on the hydrologic conditions during the tracer injection period.

  11. Fusion of multi-tracer PET images for dose painting.

    PubMed

    Lelandais, Benoît; Ruan, Su; Denœux, Thierry; Vera, Pierre; Gardin, Isabelle

    2014-10-01

    PET imaging with FluoroDesoxyGlucose (FDG) tracer is clinically used for the definition of Biological Target Volumes (BTVs) for radiotherapy. Recently, new tracers, such as FLuoroThymidine (FLT) or FluoroMisonidazol (FMiso), have been proposed. They provide complementary information for the definition of BTVs. Our work is to fuse multi-tracer PET images to obtain a good BTV definition and to help the radiation oncologist in dose painting. Due to the noise and the partial volume effect leading, respectively, to the presence of uncertainty and imprecision in PET images, the segmentation and the fusion of PET images is difficult. In this paper, a framework based on Belief Function Theory (BFT) is proposed for the segmentation of BTV from multi-tracer PET images. The first step is based on an extension of the Evidential C-Means (ECM) algorithm, taking advantage of neighboring voxels for dealing with uncertainty and imprecision in each mono-tracer PET image. Then, imprecision and uncertainty are, respectively, reduced using prior knowledge related to defects in the acquisition system and neighborhood information. Finally, a multi-tracer PET image fusion is performed. The results are represented by a set of parametric maps that provide important information for dose painting. The performances are evaluated on PET phantoms and patient data with lung cancer. Quantitative results show good performance of our method compared with other methods. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Comparison of 99mTc-UBI 29-41, 99mTc-Ciprofloxacin, 99mTc-Ciprofloxacin dithiocarbamate and 111In-biotin for targeting experimental Staphylococcus aureus and Escherichia coli foreign-body infections: an ex-vivo study.

    PubMed

    Auletta, Sveva; Baldoni, Daniela; Varani, Michela; Galli, Filippo; Hajar, Iman A; Duatti, Adriano; Ferro-Flores, Guillermina; Trampuz, Andrej; Signore, Alberto

    2017-08-28

    Diagnosis of implant-associated infection is challenging. Several radiopharmaceuticals have been described but direct comparisons are limited. Here we compared in vitro and in an animal model 99mTc-UBI, 99mTc-Ciprofloxacin, 99mTcN-CiproCS2 and 111In-DTPA-biotin for targeting E. coli (ATCC 25922) and S. aureus (ATCC 43335). Stability controls were performed with the labelled radiopharmaceuticals during 6 h in saline and serum. The in vitro binding to viable or killed bacteria was evaluated at 37 °C and 4 °C. For in vivo studies, Teflon cages were subcutaneously implanted in mice, followed by percutaneous infection. Biodistribution of i.v. injected radiolabelled radiopharmaceuticals were evaluated during 24 h in cages and dissected tissues. Labelling efficiency of all radiopharmaceuticals ranged between 94% and 98%, with high stability both in saline and in human serum. In vitro binding assays displayed a rapid but poor bacterial binding for all tested agents. Similar binding kinetic occurred also with heat-killed and ethanol-killed bacteria. In the tissue cage model, infection was detected at different time points: 99mTc-UBI and 99mTcN-CiproCS2 showed higher infected cage/sterile cage ratio at 24 h for both E. coli and S. aureus; 99mTc-Ciprofloxacin at 24 h for both E. coli and at 4 h for S. aureus; 111In-DTPA-biotin accumulates faster in both E. coli and S. aureus infected cages. 99mTc-UBI, 99mTcN-CiproCS2 showed poor in vitro binding but good in vivo binding to E. coli only. 111In-DTPA-biotin showed poor in vitro binding but good in vivo binding to S. aureus and poor to E. coli. 99mTc-Ciprofloxacin showed poor in vitro binding but good in vivo binding to all tested bacteria. The mechanism of accumulation in infected sites remains to be elucidated.

  13. Natural and Artificial (fluorescent) Tracers to Characterise Hydrogeological Functioning and to Protect Karst Aquifers

    NASA Astrophysics Data System (ADS)

    Andreo, B.; Mudarra, M.; Marin, A. I.; Barberá, J. A.

    2012-12-01

    The hydrogeological functioning and response of karst aquifers can be determined by the joint use of natural hydrogeochemical tracers, especially total organic carbon (TOC) and intrinsic fluorescence of water, together with artificial (fluorescent) tracers, under the same hydrodynamic conditions. Sharp and rapid variations in discharge, temperature, electrical conductivity and water chemistry, particularly of natural tracers of infiltration (TOC, intrinsic fluorescence and NO3-) recorded in karst spring water, confirm the existence of well developed karst conduits in the sector of the aquifer being drained, with rapid flows and very short water transit times from the surface to the springs (Mudarra et al., 2011). This is in agreement with the evidence obtained from breakthrough curves of fluorescent dye tracers (uranine, eosine, etc.). However, time lags between maximum concentrations of natural (especially TOC and intrinsic fluorescence) and artificial tracers show that the global system response is faster than that produced from a recharge concentrated at a point on the surface, even in karst sinkholes. Response and transit times of water through the karst can be calculated using both natural and artificial tracers, but flow velocities can really only be quantified using artificial tracers. Analysis of the responses obtained by natural tracers of infiltration (global system response) and artificial tracers (single response) in karst waters has revealed the usefulness and complementarity of both techniques for characterising the hydrogeological functioning of karst aquifers and, even more important, for validating contamination vulnerability mapping in these medium (Zwahlen, 2004; Andreo et al., 2006). In recent decades, several methods have been developed for such vulnerability mapping, but little progress has been made in validating their results. This validation is essential for the adequate protection of water resources in karst media, as has been shown in

  14. Biomagnetic techniques for evaluating gastric emptying, peristaltic contraction and transit time

    PubMed Central

    la Roca-Chiapas, Jose María De; Cordova-Fraga, Teodoro

    2011-01-01

    Biomagnetic techniques were used to measure motility in various parts of the gastrointestinal (GI) tract, particularly a new technique for detecting magnetic markers and tracers. A coil was used to enhance the signal from a magnetic tracer in the GI tract and the signal was detected using a fluxgate magnetometer or a magnetoresistor in an unshielded room. Estimates of esophageal transit time were affected by the position of the subject. The reproducibility of estimates derived using the new biomagnetic technique was greater than 85% and it yielded estimates similar to those obtained using scintigraphy. This technique is suitable for studying the effect of emotional state on GI physiology and for measuring GI transit time. The biomagnetic technique can be used to evaluate digesta transit time in the esophagus, stomach and colon, peristaltic frequency and gastric emptying and is easy to use in the hospital setting. PMID:22025978

  15. Biomagnetic techniques for evaluating gastric emptying, peristaltic contraction and transit time.

    PubMed

    la Roca-Chiapas, Jose María De; Cordova-Fraga, Teodoro

    2011-10-15

    Biomagnetic techniques were used to measure motility in various parts of the gastrointestinal (GI) tract, particularly a new technique for detecting magnetic markers and tracers. A coil was used to enhance the signal from a magnetic tracer in the GI tract and the signal was detected using a fluxgate magnetometer or a magnetoresistor in an unshielded room. Estimates of esophageal transit time were affected by the position of the subject. The reproducibility of estimates derived using the new biomagnetic technique was greater than 85% and it yielded estimates similar to those obtained using scintigraphy. This technique is suitable for studying the effect of emotional state on GI physiology and for measuring GI transit time. The biomagnetic technique can be used to evaluate digesta transit time in the esophagus, stomach and colon, peristaltic frequency and gastric emptying and is easy to use in the hospital setting.

  16. Study of irradiated bone. III. Scintigraphic and radiographic detection of radiation-induced osteosarcomas. [/sup 99m/Tc-pyrophosphate; rabbits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    King, M.A.; Casarett, G.W.; Weber, D.A.

    1980-05-01

    Within 1 yr after localized irradiation of a hind limb with single (1756 rads) or fractionated (4650 rads in 3 wk) x-ray doses, radiation-induced osteosarcomas were observed in four of nine single-dose rabbits and two of 11 fractionated-dose rabbits. Tumors were observed in the proximal tibia in five cases and the distal femur in one case. In terms of production of osteoid or osseous tissue, three tumors were well differentiated, one slightly differentiated, and two (spindle-cell tumors) undifferentiated. This report summarizes the Tc-99m pyrophosphate (TcPPi) imaging and autoradiographic, radiographic, and histologic studies of these osteosarcomas. The four differentiated osteosarcomas weremore » detected 1 to 2.5 mo earlier by TcPPi imaging than by radiography, whereas the two undifferentiated tumors were suspected 2 wk or 3.5 mo earlier radiographically. Autoradiograms showed TcPPi localization in bone produced by differentiated osteosarcomas, and in regions of reactive bone resorption and formation peripheral to tumors. The results support a recommendation for combined radiographic and scintigraphic techniques for the early detection of osteosarcomas.« less

  17. The measurement of skin lymph flow by isotope clearance--reliability, reproducibility, injection dynamics, and the effect of massage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mortimer, P.S.; Simmonds, R.; Rezvani, M.

    1990-12-01

    The measurement of skin lymph flow was investigated using an isotope clearance technique (ICT). Multiple lymph flow determinations were undertaken in the skin of anaesthetized large white pigs to test for reproducibility, ascertain the most suitable tracer, study the influence of injection dynamics, and observe the effect of massage as a stimulus to lymph flow. Blood clearance of tracer was also investigated. Results demonstrated that lymphatic clearance is a monoexponential function with good reproducibility under controlled laboratory conditions. 99mTc-colloid (TCK17 Cis) compared favorably with 131I-human serum albumin as a tracer and both performed better than colloid gold (198Au). Lymph flowmore » was significantly faster in one pig than in the other. No difference existed between left and right sides or between caudal and rostral sites on each flank, but clearance was significantly slower in thigh than flank skin. Sub-epidermal injections cleared faster and more consistently than either deep or subcutaneous injections. Neither injection volume nor needle tract backflow of tracer influenced results, but local massage significantly enhanced clearance. Escape of 99mTc-colloid by the blood was negligible. These results indicate that skin lymph flow can be reliably measured when conditions are controlled. Extrinsic factors such as massage strongly influence lymph flow. Greater sensitivity in detecting degrees of lymphatic insufficiency may be achieved if a standardized stimulus to lymph flow is administered during isotope clearance measurement.« less

  18. AIR INFILTRATION MEASUREMENTS USING TRACER GASES: A LITERATURE REVIEW

    EPA Science Inventory

    The report gives results of a literature review of air filtration measurements using tracer gases, including sulfur hexafluoride, hydrogen, carbon monoxide, carbon dioxide, nitrous oxide, and radioactive argon and krypton. Sulfur hexafluoride is the commonest tracer gas of choice...

  19. Synthesis of isotopically modified ZnO nanoparticles and their potential as nanotoxicity tracers

    USGS Publications Warehouse

    Dybowska, A.D.; Croteau, M.-N.; Misra, S.K.; Berhanu, D.; Luoma, S.N.; Christian, P.; O'Brien, P.; Valsami-Jones, E.

    2011-01-01

    Understanding the behavior of engineered nanoparticles in the environment and within organisms is perhaps the biggest obstacle to the safe development of nanotechnologies. Reliable tracing is a particular issue for nanoparticles such as ZnO, because Zn is an essential element and a common pollutant thus present at elevated background concentrations. We synthesized isotopically enriched (89.6%) with a rare isotope of Zn (67Zn) ZnO nanoparticles and measured the uptake of 67Zn by L. stagnalis exposed to diatoms amended with the particles. Stable isotope technique is sufficiently sensitive to determine the uptake of Zn at an exposure equivalent to lower concentration range (<15 ??g g-1). Without a tracer, detection of newly accumulated Zn is significant at Zn exposure concentration only above 5000 ??g g-1 which represents some of the most contaminated Zn conditions. Only by using a tracer we can study Zn uptake at a range of environmentally realistic exposure conditions. ?? 2010 Elsevier Ltd. All rights reserved.

  20. Sentinel lymph node detection following the hysteroscopic peritumoural injection of 99mTc-labelled albumin nanocolloid in endometrial cancer.

    PubMed

    Maccauro, Marco; Lucignani, Giovanni; Aliberti, Gianluca; Villano, Carlo; Castellani, Maria Rita; Solima, Eugenio; Bombardieri, Emilio

    2005-05-01

    The purpose of this study was to assess the feasibility of sentinel lymph node (SLN) detection in endometrial cancer patients with a dual-tracer procedure after hysteroscopic peritumoural injection. Twenty-six women with previously untreated endometrial adenocarcinoma underwent the hysteroscopic injection of 111 MBq 99mTc-Nanocoll and blue dye administered subendometrially around the lesion. On the same day, all 26 patients underwent lymphoscintigraphy, followed 3-4 h later by hysterotomy with bilateral salpingo-oophorectomy and pelvic lymphadenectomy. Para-aortic lymphadenectomy was also performed in cases of either serous or papillary carcinoma (n=7/26). All SLNs were removed and examined with haematoxylin and eosin staining and immunohistochemical techniques. The procedure was well tolerated by patients, only two experiencing transient vagal symptoms. The sensitivity of this technique for correct identification of SLNs was 100%. Lymph node metastases were found in 4 out of the 26 patients (15%), bilaterally in the external iliac region (n=1), unilaterally in the external iliac region (n=1), unilaterally in the common iliac region (n=1) and unilaterally in the para-aortic region (n=1). In all four cases, nodal metastases were located within SLNs detected by lymphoscintigraphy. Only 10 of the 26 patients (38%) had significant blue dye staining. All blue-stained SLNs were radioactive. In patients with endometrial cancer, it is feasible to use lymphatic mapping and SLN biopsy to define the topographic distribution of the lymphatic network and also to accurately detect lumbo-aortic and pelvic metastases within SLNs. In the majority of patients with early stage endometrial cancer, this procedure may avoid unnecessary radical pelvic lymphadenectomy. It may also guide para-aortic lymph node dissection on the basis of the SLN status.