Sample records for tc-mag3 sintesis formulacion

  1. [Methodological aspects related to the determination of the relative renal function using 99mTC MAG3].

    PubMed

    Ladrón De Guevara Hernández, D; Ham, H; Franken, P; Piepsz, A; Lobo Sotomayor, G

    2002-01-01

    The aim of the study was to evaluate three different methods for calculating the split renal function in patients with only one functioning kidney, keeping in mind that the split function should be zero on the side of the non-functioning kidney. We retrospectively selected 28 99mTc MAG3 renograms performed in children, 12 with unilateral nephrectomy, 4 with unilateral agenesis and 12 with a non-functioning kidney. A renal and perirenal region of interest (ROI) were delineated around the functioning kidney. The ROIs around the empty kidney were drawn symmetrically to the contralateral side. The split renal function was calculated using three different methods, the integral method, the slope method and the Patlak-Rutland algorithm. For the whole group of 28 kidneys as well as for the three categories of patients, the three methods provided a split function on the side of the non-functioning kidney close to the zero value, regardless of whether the empty kidney was the left or the right one. We recommend the use of the integral method for the whole range of split renal function with 99mTc MAG3. No significant improvement was obtained by means of the more sophisticated Patlak-Rutland method.

  2. A new contrast media for functional MR urography: Gd-MAG3.

    PubMed

    Algin, Oktay

    2011-07-01

    Tc-99m-MAG3 (tubular agent) provides high imaging quality and extraction efficiency; and has become one of the most widely used agent for scintigraphic examinations of urinary system pathologies and renal transplants. Recently, it was reported that functional magnetic resonance urography (FMRU) can be sufficient in detection of urinary tract obstruction, renal artery stenosis, calculation of kidney functions and evaluation of renal transplants. However the pharmacokinetics of magnetic resonance (MR) contrast-media used in FMRU and Tc-99m-MAG3 differs from each other. This may cause discordant results between the FMRU and most of the scintigraphic studies. To our knowledge, there is no contrast-media which is specific for FMRU. A kidney specific contrast material can be developed for FMRU studies as well. MAG3 is a good candidate for this chelation. In conclusion, MR imaging (MRI) will be the most useful and important technique for morphologic-functional evaluation of urinary system. FMRU examinations performed with MAG3 chelated gadolinium can be sufficient for the complete evaluation of urinary tract even in patients with impaired renal functions ("all in one MRI"). MRI has some important advantages including no risk for radiation exposure, high temporal and spatial resolution, no need for nephrotoxic contrast agent; besides being a fast and feasible technique. Gadolinium-containing contrast agents may cause a life-threatening adverse reaction known as nephrogenic systemic fibrosis in patients with severe renal impairment, but Gd-MAG3 may reduce the risk of nephrogenic systemic fibrosis due to its higher extraction capacity and other features. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. Detection of early changes in renal function using 99mTc-MAG3 imaging in a murine model of ischemia-reperfusion injury

    PubMed Central

    Roberts, John; Chen, Bo; Curtis, Lisa M.; Agarwal, Anupam; Sanders, Paul W.; Zinn, Kurt R.

    2012-01-01

    Accurate determination of renal function in mice is a major impediment to the use of murine models in acute kidney injury. The purpose of this study was to determine whether early changes in renal function could be detected using dynamic gamma camera imaging in a mouse model of ischemia-reperfusion (I/R) injury. C57BL/6 mice (n = 5/group) underwent a right nephrectomy, followed by either 30 min of I/R injury or sham surgery of the remaining kidney. Dynamic renal studies (21 min, 10 s/frame) were conducted before surgery (baseline) and at 5, 24, and 48 h by injection of 99mTc-mercaptoacetyltriglycine (MAG3; ~1.0 mCi/mouse) via the tail vein. The percentage of injected dose (%ID) in the kidney was calculated for each 10-s interval after MAG3 injection, using standard region of interest analyses. A defect in renal function in I/R-treated mice was detected as early as 5 h after surgery compared with sham-treated mice, identified by the increased %ID (at peak) in the I/R-treated kidneys at 100 s (P < 0.01) that remained significantly higher than sham-treated mice for the duration of the scan until 600 s (P < 0.05). At 48 h, the renal scan demonstrated functional renal recovery of the I/R mice and was comparable to sham-treated mice. Our study shows that using dynamic imaging, renal dysfunction can be detected and quantified reliably as early as 5 h after I/R insult, allowing for evaluation of early treatment interventions. PMID:17634403

  4. Dynamic 99mTc-MAG3 renography: images for quality control obtained by combining pharmacokinetic modelling, an anthropomorphic computer phantom and Monte Carlo simulated scintillation camera imaging

    NASA Astrophysics Data System (ADS)

    Brolin, Gustav; Sjögreen Gleisner, Katarina; Ljungberg, Michael

    2013-05-01

    In dynamic renal scintigraphy, the main interest is the radiopharmaceutical redistribution as a function of time. Quality control (QC) of renal procedures often relies on phantom experiments to compare image-based results with the measurement setup. A phantom with a realistic anatomy and time-varying activity distribution is therefore desirable. This work describes a pharmacokinetic (PK) compartment model for 99mTc-MAG3, used for defining a dynamic whole-body activity distribution within a digital phantom (XCAT) for accurate Monte Carlo (MC)-based images for QC. Each phantom structure is assigned a time-activity curve provided by the PK model, employing parameter values consistent with MAG3 pharmacokinetics. This approach ensures that the total amount of tracer in the phantom is preserved between time points, and it allows for modifications of the pharmacokinetics in a controlled fashion. By adjusting parameter values in the PK model, different clinically realistic scenarios can be mimicked, regarding, e.g., the relative renal uptake and renal transit time. Using the MC code SIMIND, a complete set of renography images including effects of photon attenuation, scattering, limited spatial resolution and noise, are simulated. The obtained image data can be used to evaluate quantitative techniques and computer software in clinical renography.

  5. Can computed tomography volumetry of the renal cortex replace MAG3-scintigraphy in all patients for determining split renal function?

    PubMed

    Houbois, Christian; Haneder, Stefan; Merkt, Martin; Morelli, John N; Schmidt, Matthias; Hellmich, Martin; Mueller, Roman-Ulrich; Wahba, Roger; Maintz, David; Puesken, Michael

    2018-06-01

    The current gold standard for determination of split renal function (SRF) is Tc-99m-mercapto-acetyltriglycin (MAG3) scintigraphy. Initial studies comparing MAG3-scintigraphy and CT-based renal cortex volumetry (RCV) for calculation of SRF have shown similar results in highly selected patient collectives with normal renal function (i.e. living kidney donors). This study aims to compare MAG3-scintigraphy and CT-RCV within a large unselected patient collective including patients with impaired renal function. For this assessment, 279 datasets (131 men, 148 women; mean age: 54.2 ± 12.9 years, range: 24-84 years) of patients who underwent MAG3-scintigraphy and contrast-enhanced abdominal CT within two weeks were retrospectively analyzed. Two independent readers assessed the CT-RCV in all CT datasets using a semi-automated volumetry tool. The MAG3-scintigraphy and CT-RCV methods were compared, stratified for the eGFR. Statistical analysis included descriptive statistics as well as inter- observer agreement. The absolute mean difference between the percentage contribution of the left and the right kidneys in total MAG3-clearance was 8.6%. Independent of eGFR, an overall sufficient agreement between both methods was established in all patients. A relatively small, tolerable systemic error resulted in an underestimation (max. 2%) of the left renal contribution to overall RCV. The results demonstrate that CT-RCV is a potential clinical replacement for MAG3-scintigraphy for calculation of SRF: CT-RCV demonstrates clinically tolerable differences with MAG3-scintigraphy, independent of patient eGFR. The relative complexity of the RCV method utilized is a potential limitation and may have contributed to the acceptable but only fair to moderate level of intra-reader reliability. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Structure and Properties of fac-[Re(I)(CO)3(NTA)](2-) (NTA(3-) = Trianion of Nitrilotriacetic Acid) and fac-[Re(I)(CO)3(L)](n-) Analogues Useful for Assessing the Excellent Renal Clearance of the fac-[(99m)Tc(I)(CO)3(NTA)](2-) Diagnostic Renal Agent.

    PubMed

    Klenc, Jeffrey; Lipowska, Malgorzata; Abhayawardhana, Pramuditha L; Taylor, Andrew T; Marzilli, Luigi G

    2015-07-06

    We previously identified two new agents based on the [(99m)Tc(V)O](3+) core with renal clearances in human volunteers 30% higher than that of the widely used clinical tracer (99m)Tc-MAG3 (MAG3(5-) = penta-anion of mercaptoacetyltriglycine). However, renal agents with even higher clearances are needed. More recently, we changed our focus from the [(99m)Tc(V)O](3+) core to the discovery of superior tracers based on the fac-[(99m)Tc(I)(CO)3](+) core. Compared to (99m)Tc-MAG3, fac-[(99m)Tc(I)(CO)3(NTA)](2-) (NTA(3-) = trianion of nitrilotriacetic acid) holds great promise by virtue of its efficient renal clearance via tubular secretion and the absence of hepatobiliary elimination, even in patients with severely reduced renal function. We report here NMR, molecular (X-ray) structure, and solution data on fac-[Re(I)(CO)3(NTA)](2-) with a -CH2CO2(-) dangling monoanionic chain and on two fac-[Re(I)(CO)3(L)](-) analogues with either a -CH2CONH2 or a -CH2CH2OH dangling neutral chain. In these three fac-[Re(I)(CO)3(L)](n-) complexes, the fac-[Re(I)(CO)3(N(CH2CO2)2)](-) moiety is structurally similar and has similar electronic properties (as assessed by NMR data). In reported and ongoing studies, the two fac-[(99m)Tc(I)(CO)3(L)](-) analogues with these neutral dangling chains were found to have pharmacokinetic properties very similar to those of fac-[(99m)Tc(I)(CO)3(NTA)](2-). Therefore, we reach the unexpected conclusion that in fac-[(99m)Tc(I)(CO)3(L)](n-) agents, renal clearance is affected much more than anticipated by features of the core plus the chelate rings (the [(99m)Tc(I)(CO)3(N(CH2CO2)2)](-) moiety) than by the presence of a negatively charged dangling carboxylate chain.

  7. MAG3D and its application to internal flowfield analysis

    NASA Technical Reports Server (NTRS)

    Lee, K. D.; Henderson, T. L.; Choo, Y. K.

    1992-01-01

    MAG3D (multiblock adaptive grid, 3D) is a 3D solution-adaptive grid generation code which redistributes grid points to improve the accuracy of a flow solution without increasing the number of grid points. The code is applicable to structured grids with a multiblock topology. It is independent of the original grid generator and the flow solver. The code uses the coordinates of an initial grid and the flow solution interpolated onto the new grid. MAG3D uses a numerical mapping and potential theory to modify the grid distribution based on properties of the flow solution on the initial grid. The adaptation technique is discussed, and the capability of MAG3D is demonstrated with several internal flow examples. Advantages of using solution-adaptive grids are also shown by comparing flow solutions on adaptive grids with those on initial grids.

  8. Preclinical evaluation of 99mTc(CO)3-aspartic-N-monoacetic acid, 99mTc(CO)3(ASMA), a new renal radiotracer with pharmacokinetic properties comparable to 131I-OIH

    PubMed Central

    Lipowska, Malgorzata; Klenc, Jeffrey; Marzilli, Luigi G.; Taylor, Andrew T.

    2014-01-01

    In an ongoing effort to develop a renal tracer with pharmacokinetic properties comparable to PAH and superior to those of both 99mTc-MAG3 and 131I-OIH, we evaluated a new renal tricarbonyl radiotracer based on the aspartic-N-monoacetic acid ligand, 99mTc(CO)3(ASMA). The ASMA ligand features two carboxyl groups and an amine function for the coordination of the {99mTc(CO)3}+ core as well as a dangling carboxylate to facilitate rapid renal clearance. Methods rac-ASMA and L-ASMA were labeled with a 99mTc-tricarbonyl precursor and radiochemical purity of the labeled products was determined by HPLC. Using 131I-OIH as an internal control, we evaluated biodistribution in normal rats with 99mTc(CO)3(ASMA) isomers and in rats with renal pedicle ligation with 99mTc(CO)3(rac-ASMA). Clearance studies were conducted in 4 additional rats. In vitro radiotracer stability was determined in PBS buffer pH 7.4 and in challenge studies with cysteine and histidine. 99mTc(CO)3(ASMA) metabolites in urine were analyzed by HPLC. Results Both 99mTc(CO)3(ASMA) preparations had > 99% radiochemical purity and were stable in PBS buffer pH 7.4 for 24 h. Challenge studies on both revealed no significant displacement of the ligand. In normal rats, % injected dose in urine at 10 and 60 min for both preparations averaged 103% and 106% that of 131I-OIH, respectively. The renal clearances of 99mTc(CO)3(rac-ASMA) and 131I-OIH were comparable (P = 0.48). The tracer was excreted unchanged in the urine, proving its in vivo stability. In pedicle-ligated rats, 99mTc(CO)3(rac-ASMA) had less excretion into the bowel (P < 0.05) and was better retained in the blood (P < 0.05) than 131I-OIH. Conclusion Both 99mTc(CO)3(ASMA) complexes have pharmacokinetic properties in rats comparable to or superior to those of 131I-OIH, and human studies are warranted for their further evaluation. PMID:22717977

  9. iRENEX: a clinically informed decision support system for the interpretation of ⁹⁹mTc-MAG3 scans to detect renal obstruction.

    PubMed

    Garcia, Ernest V; Taylor, Andrew; Folks, Russell; Manatunga, Daya; Halkar, Raghuveer; Savir-Baruch, Bital; Dubovsky, Eva

    2012-09-01

    Decision support systems for imaging analysis and interpretation are rapidly being developed and will have an increasing impact on the practice of medicine. RENEX is a renal expert system to assist physicians evaluate suspected obstruction in patients undergoing mercaptoacetyltriglycine (MAG3) renography. RENEX uses quantitative parameters extracted from the dynamic renal scan data using QuantEM™II and heuristic rules in the form of a knowledge base gleaned from experts to determine if a kidney is obstructed; however, RENEX does not have access to and could not consider the clinical information available to diagnosticians interpreting these studies. We designed and implemented a methodology to incorporate clinical information into RENEX, implemented motion detection and evaluated this new comprehensive system (iRENEX) in a pilot group of 51 renal patients. To reach a conclusion as to whether a kidney is obstructed, 56 new clinical rules were added to the previously reported 60 rules used to interpret quantitative MAG3 parameters. All the clinical rules were implemented after iRENEX reached a conclusion on obstruction based on the quantitative MAG3 parameters, and the evidence of obstruction was then modified by the new clinical rules. iRENEX consisted of a library to translate parameter values to certainty factors, a knowledge base with 116 heuristic interpretation rules, a forward chaining inference engine to determine obstruction and a justification engine. A clinical database was developed containing patient histories and imaging report data obtained from the hospital information system associated with the pertinent MAG3 studies. The system was fine-tuned and tested using a pilot group of 51 patients (21 men, mean age 58.2 ± 17.1 years, 100 kidneys) deemed by an expert panel to have 61 unobstructed and 39 obstructed kidneys. iRENEX, using only quantitative MAG3 data agreed with the expert panel in 87 % (34/39) of obstructed and 90 % (55/61) of

  10. Design and evaluation of new Tc-99m-labeled lactam bridge-cyclized alpha-MSH peptides for melanoma imaging.

    PubMed

    Guo, Haixun; Gallazzi, Fabio; Miao, Yubin

    2013-04-01

    The purpose of this study was to examine the melanoma targeting and imaging properties of new (99m)Tc-labeled lactam bridge-cyclized alpha-melanocyte stimulating hormone (α-MSH) peptides using bifunctional chelating agents. MAG3-GGNle-CycMSH(hex), AcCG3-GGNle-CycMSH(hex), and HYNIC-GGNle-CycMSH(hex) peptides were synthesized, and their melanocortin-1 (MC1) receptor binding affinities were determined in B16/F1 melanoma cells. The biodistribution of (99m)Tc-MAG3-GGNle-CycMSH(hex), (99m)Tc-AcCG3-GGNle-CycMSH(hex), (99m)Tc(CO)3-HYNIC-GGNle-CycMSH(hex), and (99m)Tc(EDDA)-HYNIC-GGNle-CycMSH(hex) were determined in B16/F1 melanoma-bearing C57 mice at 2 h postinjection to select a lead peptide for further evaluation. The melanoma targeting and imaging properties of (99m)Tc(EDDA)-HYNIC-GGNle-CycMSH(hex) were further examined because of its high melanoma uptake and fast urinary clearance. The IC50 values of MAG3-GGNle-CycMSH(hex), AcCG3-GGNle-CycMSH(hex), and HYNIC-GGNle-CycMSH(hex) were 1.0 ± 0.05, 1.2 ± 0.19, and 0.6 ± 0.04 nM in B16/F1 melanoma cells, respectively. Among these four (99m)Tc-peptides, (99m)Tc(EDDA)-HYNIC-GGNle-CycMSH(hex) exhibited the highest melanoma uptake (14.14 ± 4.90% ID/g) and fastest urinary clearance (91.26 ± 1.96% ID) at 2 h postinjection. (99m)Tc(EDDA)-HYNIC-GGNle-CycMSH(hex) showed high tumor to normal organ uptake ratios except for the kidneys. The tumor/kidney uptake ratios of (99m)Tc(EDDA)-HYNIC-GGNle-CycMSH(hex) were 2.50 and 3.55 at 4 and 24 h postinjection. The melanoma lesions were clearly visualized by SPECT/CT using (99m)Tc(EDDA)-HYNIC-GGNle-CycMSH(hex) as an imaging probe at 2 h postinjection. Overall, high melanoma uptake coupled with fast urinary clearance of (99m)Tc(EDDA)-HYNIC-GGNle-CycMSH(hex) highlighted its potential for metastatic melanoma detection in the future.

  11. Design and Evaluation of New Tc-99m-Labeled Lactam Bridge-Cyclized Alpha-MSH Peptides for Melanoma Imaging

    PubMed Central

    Guo, Haixun; Gallazzi, Fabio; Miao, Yubin

    2013-01-01

    The purpose of this study was to examine the melanoma targeting and imaging properties of new 99mTc-labeled lactam bridge-cyclized alpha-melanocyte stimulating hormone (α-MSH) peptides using bifunctional chelating agents. MAG3-GGNle-CycMSHhex, AcCG3-GGNle-CycMSHhex and HYNIC-GGNle-CycMSHhex peptides were synthesized and their melanocortin-1 (MC1) receptor binding affinities were determined in B16/F1 melanoma cells. The biodistribution of 99mTc-MAG3-GGNle-CycMSHhex, 99mTc-AcCG3-GGNle-CycMSHhex, 99mTc(CO)3-HYNIC-GGNle-CycMSHhex and 99mTc(EDDA)-HYNIC-GGNle-CycMSHhex were determined in B16/F1 melanoma-bearing C57 mice at 2 h post-injection to select a lead peptide for further evaluation. The melanoma targeting and imaging properties of 99mTc(EDDA)-HYNIC-GGNle-CycMSHhex were further examined because of its high melanoma uptake and fast urinary clearance. The IC50 values of MAG3-GGNle-CycMSHhex, AcCG3-GGNle-CycMSHhex and HYNIC-GGNle-CycMSHhex were 1.0 ± 0.05, 1.2 ± 0.19 and 0.6 ± 0.04 nM in B16/F1 melanoma cells, respectively. Among these four 99mTc-peptides, 99mTc(EDDA)-HYNIC-GGNle-CycMSHhex exhibited the highest melanoma uptake (14.14 ± 4.90% ID/g) and fastest urinary clearance (91.26 ± 1.96% ID) at 2 h post-injection. 99mTc(EDDA)-HYNIC-GGNle-CycMSHhex showed high tumor to normal organ uptake ratios except for the kidneys. The tumor/kidney uptake ratios of 99mTc(EDDA)-HYNIC-GGNle-CycMSHhex were 2.50 and 3.55 at 4 and 24 h post-injection. The melanoma lesions were clearly visualized by SPECT/CT using 99mTc(EDDA)-HYNIC-GGNle-CycMSHhex as an imaging probe at 2 h post-injection. Overall, high melanoma uptake coupled with fast urinary clearance of 99mTc(EDDA)-HYNIC-GGNle-CycMSHhex highlighted its potential for metastatic melanoma detection in the future. PMID:23418722

  12. Initial Evaluation of (99m)Tc(CO)3(ASMA) as a Renal Tracer in Healthy Human Volunteers.

    PubMed

    Lipowska, Malgorzata; Klenc, Jeffrey; Folks, Russell D; Taylor, Andrew T

    2014-09-01

    Preclinical studies in rats showed that two of (99m)Tc(CO)3(ASMA) isomers (rac- and L-ASMA) had pharmacokinetic properties equivalent to that of (131)I-OIH, the radiopharmaceutical standard for the measurement of effective renal plasma flow. The aim of this study was to evaluate the pharmacokinetics of (99m)Tc(CO)3(ASMA) isomers in healthy human subjects. Three ASMA ligands (rac-, L- and D-ASMA) were labeled with (99m)Tc(CO)3 using an IsoLink kit (Covidien), and each formed (99m)Tc(CO)3(ASMA) tracer was co-injected with (131)I-OIH into healthy human subjects followed by sequential imaging, plasma clearance measurements and timed urine collection. Plasma protein binding, red cell uptake and percent injected dose in the urine were determined. Urine from each group of volunteers was analyzed for metabolites by HPLC. Image quality was excellent with all three agents. Each (99m)Tc(CO)3(ASMA) preparation was excreted unchanged in the urine. The plasma clearance ratio ((99m)Tc(CO)3(ASMA)/(131)I-OIH) was 81 ± 3 % for D-ASMA compared to only 20 ± 4 % for L-ASMA and 37 ± 7 % for rac-ASMA; the 81 % clearance ratio for D-ASMA isomer is still ∼ 30 % higher than the (99m)Tc-MAG3/(131)I-OIH clearance ratio (∼50-60 %). Red cell uptake was similar for all three tracers (6-9 %), and all tracers had a relatively rapid renal excretion; at 3 h, the (99m)Tc(CO)3(ASMA)/(131)I-OIH urine ratio was 100 ± 3 % for D-ASMA, 80 ± 2 % for L-ASMA and 88 ± 1 % for rac-ASMA. The renal excretion characteristics of (99m)Tc(CO)3(D-ASMA) in humans are superior to those of the other two (99m)Tc(CO)3(ASMA) isomers studied, but are still inferior to (131)I-OIH, even though there was no difference in the clearance of two of (99m)Tc(CO)3(ASMA) isomers and (131)I-OIH in rats. The work described here demonstrates the sensitivity in in vivo biological behavior of (99m)Tc(CO)3(ASMA) isomers to their subtle structural differences.

  13. (99m)Tc-MAG3 diuretic renography in diagnosis of obstructive nephropathy in adults: a comparison between F-15 and a new procedure F+10(sp) in seated position.

    PubMed

    Tartaglione, Girolamo; D'Addessi, Alessandro; De Waure, Chiara; Pagan, Marco; Raccioppi, Marco; Sacco, Emilio; Cadeddu, Chiara; Vittori, Matteo; Bassi, Pier Francesco; Ferretti, Alice; Al-Nahhas, Adil; Rubello, Domenico

    2013-06-01

    The objective of this study was to compare 2 diuretic renography procedures: F-15 versus F+10(sp) for diagnosis of obstructive uropathy in adults. Thirty-six patients with unilateral or bilateral hydronephrosis had 2 consecutive Tc-MAG3 diuretic renograms within 7 days, using the widely used procedure F-15 in supine position, and a new seated-position procedure whereby the patient drinks 400 to 500 mL of water at 5 minutes and receives an injection of 20 mg of furosemide at 10 minutes [F+10 (sp)]. F-15 showed nonobstructive results in 63.9% of kidneys, obstruction in 26.4%, and equivocal findings in 6.9% and was not applicable in 2.8%. F+10(sp) showed nonobstructive results in 70.9%, obstruction in 27.8%, and equivocal result in 1.4% of kidneys. Nephroptosis was observed by F+10(sp) in 22.2% of kidneys. Adverse effects reported for the F-15 were hypotension in 2 patients, renal colic in 3 patients, and interruption due to voiding in 5 patients. No adverse effects were reported for F+10(sp). This study shows that the F+10(sp) procedure reduces the equivocal findings of F-15 procedure in 36 patients. It can improve the accuracy and compliance, avoiding adverse effects and reducing bladder filling-related problems.

  14. [Improvement in nuclear medicine diagnosis of kidney function using 99m technetium mercaptoacetyltriglycine (MAG3)].

    PubMed

    Erpenbach, K; Ebert, A; Wieler, H

    1991-03-01

    Renal scintigraphy and clearance measurement are indispensable in nephro-urologic disorders. A continuous series of 103 sequential scintigraphies and clearance measurements were performed with the new technetium-labelled agent MAG3 (Gamma-kamera, Phillips Tomo Diagnost) and 131I-orthohippuric acid (OIH) using the Oberhausen method (Nucleopan, Siemens). The time-activity curves obtained with the two radionuclides agreed exactly. Reaching a tubular excretion rate of nearly 90%, the clearance of MAG3 differed by no more than 6% from the OIH clearance in 95% of the cases. The factor between clearances of the two radionuclides was determined by means of a commercially available software according to the Oberhausen method and amounted to 0.59 +/- 0.09. The favorable physical properties and high activity of MAG3 permit exact examination of tubular function and better assessment of renal morphology than hippuran-labelled radionuclides. The low radiation dose combined with a better spatial resolution, especially, the constant availability in a nuclear medicine department should give the preference to MAG3.

  15. A novel approach to infection imaging using a synthetic Tc-99m-labeled leukotactic peptide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Som, P.; Oster, Z.H.; Sharma, S.

    1996-05-01

    RMT1, a synthetic peptide binding to PMN and macrophage receptors was labeled with Tc-99m and investigated as a potential imaging agent for abscess and inflammation. Experimental abscesses were induced in rabbits and dogs by turpentine and E.coli injection. After injection of Tc-99m-RMT1 two and twelve day old abscesses were visualized within 20 min. In initial studies, a dose of 30 {mu}g of peptide/3 mCi was used. This amount was subsequently reduced to 1.5 {mu}g peptide with same amount of Tc-99m yielding similar imaging results. Technetium-99m-IgG and Tc-99m-MAG-3 were used as positive and negative controls, respectively. After injection of IgG abscessesmore » were visualized but activity in blood was always higher than in abscess. When using Tc-99m RMT1 rapid abscess visualization and faster blood clearance was observed. The accumulation of RMT1 was monophasic, i.e., following the initial visualization, activity continued to build up continuously for 1{1/2} hr. Tc-99m-MAG3 accumulated initially in abscess, but activity washed out. In dogs, RMT1 blood clearance showed three components: a fast component with t{1/2}=1.9 min, 73%, intermediate t{1/2}=22 min, 24.5% and slow component, t{1/2}=115, 9.5% with 3 hours cumulative urine excretion of 40-51%. RMT1 appears to be more advantageous than currently available methods because of rapidity of imaging, simpler preparation before injection and will probably be less expensive and time consuming compared to labeled WBC. These results indicate that clinical experiments are warranted.« less

  16. Crystal structures of 3-methyladenine DNA glycosylase MagIII and the recognition of alkylated bases

    PubMed Central

    Eichman, Brandt F.; O’Rourke, Eyleen J.; Radicella, J.Pablo; Ellenberger, Tom

    2003-01-01

    DNA glycosylases catalyze the excision of chemically modified bases from DNA. Although most glycosylases are specific to a particular base, the 3-methyladenine (m3A) DNA glycosylases include both highly specific enzymes acting on a single modified base, and enzymes with broader specificity for alkylation-damaged DNA. Our structural understanding of these different enzymatic specificities is currently limited to crystal and NMR structures of the unliganded enzymes and complexes with abasic DNA inhibitors. Presented here are high-resolution crystal structures of the m3A DNA glycosylase from Helicobacter pylori (MagIII) in the unliganded form and bound to alkylated bases 3,9-dimethyladenine and 1,N6-ethenoadenine. These are the first structures of a nucleobase bound in the active site of a m3A glycosylase belonging to the helix–hairpin–helix superfamily. MagIII achieves its specificity for positively-charged m3A not by direct interactions with purine or methyl substituent atoms, but rather by stacking the base between two aromatic side chains in a pocket that excludes 7-methylguanine. We report base excision and DNA binding activities of MagIII active site mutants, together with a structural comparison of the HhH glycosylases. PMID:14517230

  17. Demystifying Mag-Lev.

    ERIC Educational Resources Information Center

    Ruiz, Ernest; And Others

    1991-01-01

    Presented are classroom activities in which students explore the potential use of magnetic levitation for transportation purposes. The advantages of using a MagLev transportation system instead of conventional trains are discussed. Directions for designing and building a MagLev track and circuit are provided. (KR)

  18. BinMag: Widget for comparing stellar observed with theoretical spectra

    NASA Astrophysics Data System (ADS)

    Kochukhov, O.

    2018-05-01

    BinMag examines theoretical stellar spectra computed with Synth/SynthMag/Synmast/Synth3/SME spectrum synthesis codes and compare them to observations. An IDL widget program, BinMag applies radial velocity shift and broadening to the theoretical spectra to account for the effects of stellar rotation, radial-tangential macroturbulence, instrumental smearing. The code can also simulate spectra of spectroscopic binary stars by appropriate coaddition of two synthetic spectra. Additionally, BinMag can be used to measure equivalent width, fit line profile shapes with analytical functions, and to automatically determine radial velocity and broadening parameters. BinMag interfaces with the Synth3 (ascl:1212.010) and SME (ascl:1202.013) codes, allowing the user to determine chemical abundances and stellar atmospheric parameters from the observed spectra.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, H.B.; Blaufox, M.D.

    Rats with one kidney clamped (2K1C), both kidneys clamped (2K2C), unilaterally nephrectomized with remaining kidney clamped (1K1C), and normals, were studied using /sup 99m/Tc mercaptoacetyltriglycine ((/sup 99m/Tc)MAG-3) and /sup 131/I orthoiodohippurate ((/sup 131/I)OIH). Clearances of (/sup 99m/Tc)MAG-3 and (/sup 131/I)OIH were performed after constricted rats became hypertensive. Clearances were repeated after i.v. Captopril. Clearances of (/sup 99m/Tc)MAG-3 and (/sup 131/I)OIH in normals didn't change significantly after Captopril. Clearances of (/sup 99m/Tc)MAG-3 and (/sup 131/I)OIH decreased insignificantly after Captopril in the 2K2C model. in the 2K1C group, normal kidney clearance increased ((/sup 99m/Tc)MAG-3 p less than 0.01 and (/sup 131/I)OIH pmore » less than 0.025) and clamped kidney clearance decreased after inhibition ((/sup 99m/Tc)MAG-3, p less than 0.01, (/sup 131/I)OIH p less than 0.02). Clearances increased in the 1K1C group after Captopril ((/sup 99m/Tc)MAG-3 p less than 0.0025 and (/sup 131/I)OIH, p less than 0.001). The ratio of (/sup 99m/Tc)MAG-3 to (/sup 131/I)OIH before Captopril was 0.81 and 0.84 after Captopril. Changes in renal function after Captopril depend on the model of renovascular hypertension and possibly the dose administered. Technetium-99m MAG-3 clearance parallels (/sup 131/I)orthoiodohippurate in renovascular hypertension.« less

  20. Lipid rafts mediate the interaction between myelin-associated glycoprotein (MAG) on myelin and MAG-receptors on neurons.

    PubMed

    Vinson, Mary; Rausch, Oliver; Maycox, Peter R; Prinjha, Rab K; Chapman, Debra; Morrow, Rachel; Harper, Alex J; Dingwall, Colin; Walsh, Frank S; Burbidge, Stephen A; Riddell, David R

    2003-03-01

    The interaction between myelin-associated glycoprotein (MAG), expressed at the periaxonal membrane of myelin, and receptors on neurons initiates a bidirectional signalling system that results in inhibition of neurite outgrowth and maintenance of myelin integrity. We show that this involves a lipid-raft to lipid-raft interaction on opposing cell membranes. MAG is exclusively located in low buoyancy Lubrol WX-insoluble membrane fractions isolated from whole brain, primary oligodendrocytes, or MAG-expressing CHO cells. Localisation within these domains is dependent on cellular cholesterol and occurs following terminal glycosylation in the trans-Golgi network, characteristics of association with lipid rafts. Furthermore, a recombinant form of MAG interacts specifically with lipid-raft fractions from whole brain and cultured cerebellar granule cells, containing functional MAG receptors GT1b and Nogo-66 receptor and molecules required for transduction of signal from MAG into neurons. The localisation of both MAG and MAG receptors within lipid rafts on the surface of opposing cells may create discrete areas of high avidity multivalent interaction, known to be critical for signalling into both cell types. Localisation within lipid rafts may provide a molecular environment that facilitates the interaction between MAG and multiple receptors and also between MAG ligands and molecules involved in signal transduction.

  1. MAG-EPA reduces severity of DSS-induced colitis in rats.

    PubMed

    Morin, Caroline; Blier, Pierre U; Fortin, Samuel

    2016-05-15

    Ulcerative colitis (UC) is a chronic disease characterized by diffuse inflammation of the intestinal mucosa of the large bowel. Omega-33) fatty acid supplementation has been associated with a decreased production of inflammatory cytokines involved in UC pathogenesis. The aim of this study was to determine the preventive and therapeutic potential of eicosapentaenoic acid monoglyceride (MAG-EPA) in an in vivo rats model of UC induced by dextran sulfate sodium (DSS). DSS rats were untreated or treated per os with MAG-EPA. Morphological, histological, and biochemical analyses were performed following MAG-EPA administrations. Morphological and histological analyses revealed that MAG-EPA pretreatment (12 days pre-DSS) and treatment (6 days post-DSS) exhibited strong activity in reducing severity of disease in DSS rats. Following MAG-EPA administrations, tissue levels of the proinflammatory cytokines TNF-α, IL-1β, and IL-6 were markedly lower compared with rats treated only with DSS. MAG-EPA per os administration decrease neutrophil infiltration in colon tissues, as depicted by myelohyperoxidase activity. Results also revealed a reduced activation of NF-κB pathways correlated with a decreased expression of COX-2 in colon homogenates derived from MAG-EPA-pretreated and treated rats. Tension measurements performed on colon tissues revealed that contractile responses to methacholine and relaxing effect induced by sodium nitroprusside were largely increased following MAG-EPA treatment. The combined treatment of MAG-EPA and vitamin E displayed an antagonistic effect on anti-inflammatory properties of MAG-EPA in DSS rats. Copyright © 2016 the American Physiological Society.

  2. Ancestor of land plants acquired the DNA-3-methyladenine glycosylase (MAG) gene from bacteria through horizontal gene transfer.

    PubMed

    Fang, Huimin; Huangfu, Liexiang; Chen, Rujia; Li, Pengcheng; Xu, Shuhui; Zhang, Enying; Cao, Wei; Liu, Li; Yao, Youli; Liang, Guohua; Xu, Chenwu; Zhou, Yong; Yang, Zefeng

    2017-08-24

    The origin and evolution of land plants was an important event in the history of life and initiated the establishment of modern terrestrial ecosystems. From water to terrestrial environments, plants needed to overcome the enhanced ultraviolet (UV) radiation and many other DNA-damaging agents. Evolving new genes with the function of DNA repair is critical for the origin and radiation of land plants. In bacteria, the DNA-3-methyladenine glycosylase (MAG) recognizes of a variety of base lesions and initiates the process of the base excision repair for damaged DNA. The homologs of MAG gene are present in all major lineages of streptophytes, and both the phylogenic and sequence similarity analyses revealed that green plant MAG gene originated through an ancient horizontal gene transfer (HGT) event from bacteria. Experimental evidence demonstrated that the expression of the maize ZmMAG gene was induced by UV and zeocin, both of which are known as DNA-damaging agents. Further investigation revealed that Streptophyta MAG genes had undergone positive selection during the initial evolutionary period in the ancestor of land plants. Our findings demonstrated that the ancient HGT of MAG to the ancestor of land plants probably played an important role in preadaptation to DNA-damaging agents in terrestrial environments.

  3. MAG4 versus alternative techniques for forecasting active region flare productivity.

    PubMed

    Falconer, David A; Moore, Ronald L; Barghouty, Abdulnasser F; Khazanov, Igor

    2014-05-01

    MAG4 is a technique of forecasting an active region's rate of production of major flares in the coming few days from a free magnetic energy proxy. We present a statistical method of measuring the difference in performance between MAG4 and comparable alternative techniques that forecast an active region's major-flare productivity from alternative observed aspects of the active region. We demonstrate the method by measuring the difference in performance between the "Present MAG4" technique and each of three alternative techniques, called "McIntosh Active-Region Class," "Total Magnetic Flux," and "Next MAG4." We do this by using (1) the MAG4 database of magnetograms and major flare histories of sunspot active regions, (2) the NOAA table of the major-flare productivity of each of 60 McIntosh active-region classes of sunspot active regions, and (3) five technique performance metrics (Heidke Skill Score, True Skill Score, Percent Correct, Probability of Detection, and False Alarm Rate) evaluated from 2000 random two-by-two contingency tables obtained from the databases. We find that (1) Present MAG4 far outperforms both McIntosh Active-Region Class and Total Magnetic Flux, (2) Next MAG4 significantly outperforms Present MAG4, (3) the performance of Next MAG4 is insensitive to the forward and backward temporal windows used, in the range of one to a few days, and (4) forecasting from the free-energy proxy in combination with either any broad category of McIntosh active-region classes or any Mount Wilson active-region class gives no significant performance improvement over forecasting from the free-energy proxy alone (Present MAG4). Quantitative comparison of performance of pairs of forecasting techniques Next MAG4 forecasts major flares more accurately than Present MAG4 Present MAG4 forecast outperforms McIntosh AR Class and total magnetic flux.

  4. A Software Engine to Justify the Conclusions of an Expert System for Detecting Renal Obstruction on 99mTc-MAG3 Scans

    PubMed Central

    Garcia, Ernest V.; Taylor, Andrew; Manatunga, Daya; Folks, Russell

    2013-01-01

    The purposes of this study were to describe and evaluate a software engine to justify the conclusions reached by a renal expert system (RENEX) for assessing patients with suspected renal obstruction and to obtain from this evaluation new knowledge that can be incorporated into RENEX to attempt to improve diagnostic performance. Methods RENEX consists of 60 heuristic rules extracted from the rules used by a domain expert to generate the knowledge base and a forward-chaining inference engine to determine obstruction. The justification engine keeps track of the sequence of the rules that are instantiated to reach a conclusion. The interpreter can then request justification by clicking on the specific conclusion. The justification process then reports the English translation of all concatenated rules instantiated to reach that conclusion. The justification engine was evaluated with a prospective group of 60 patients (117 kidneys). After reviewing the standard renal mercaptoacetyltriglycine (MAG3) scans obtained before and after the administration of furosemide, a masked expert determined whether each kidney was obstructed, whether the results were equivocal, or whether the kidney was not obstructed and identified and ranked the main variables associated with each interpretation. Two parameters were then tabulated: the frequency with which the main variables associated with obstruction by the expert were also justified by RENEX and the frequency with which the justification rules provided by RENEX were deemed to be correct by the expert. Only when RENEX and the domain expert agreed on the diagnosis (87 kidneys) were the results used to test the justification. Results RENEX agreed with 91% (184/203) of the rules supplied by the expert for justifying the diagnosis. RENEX provided 103 additional rules justifying the diagnosis; the expert agreed that 102 (99%) were correct, although the rules were considered to be of secondary importance. Conclusion We have described and

  5. A software engine to justify the conclusions of an expert system for detecting renal obstruction on 99mTc-MAG3 scans.

    PubMed

    Garcia, Ernest V; Taylor, Andrew; Manatunga, Daya; Folks, Russell

    2007-03-01

    The purposes of this study were to describe and evaluate a software engine to justify the conclusions reached by a renal expert system (RENEX) for assessing patients with suspected renal obstruction and to obtain from this evaluation new knowledge that can be incorporated into RENEX to attempt to improve diagnostic performance. RENEX consists of 60 heuristic rules extracted from the rules used by a domain expert to generate the knowledge base and a forward-chaining inference engine to determine obstruction. The justification engine keeps track of the sequence of the rules that are instantiated to reach a conclusion. The interpreter can then request justification by clicking on the specific conclusion. The justification process then reports the English translation of all concatenated rules instantiated to reach that conclusion. The justification engine was evaluated with a prospective group of 60 patients (117 kidneys). After reviewing the standard renal mercaptoacetyltriglycine (MAG3) scans obtained before and after the administration of furosemide, a masked expert determined whether each kidney was obstructed, whether the results were equivocal, or whether the kidney was not obstructed and identified and ranked the main variables associated with each interpretation. Two parameters were then tabulated: the frequency with which the main variables associated with obstruction by the expert were also justified by RENEX and the frequency with which the justification rules provided by RENEX were deemed to be correct by the expert. Only when RENEX and the domain expert agreed on the diagnosis (87 kidneys) were the results used to test the justification. RENEX agreed with 91% (184/203) of the rules supplied by the expert for justifying the diagnosis. RENEX provided 103 additional rules justifying the diagnosis; the expert agreed that 102 (99%) were correct, although the rules were considered to be of secondary importance. We have described and evaluated a software engine

  6. MAG4 versus alternative techniques for forecasting active region flare productivity

    PubMed Central

    Falconer, David A; Moore, Ronald L; Barghouty, Abdulnasser F; Khazanov, Igor

    2014-01-01

    MAG4 is a technique of forecasting an active region's rate of production of major flares in the coming few days from a free magnetic energy proxy. We present a statistical method of measuring the difference in performance between MAG4 and comparable alternative techniques that forecast an active region's major-flare productivity from alternative observed aspects of the active region. We demonstrate the method by measuring the difference in performance between the “Present MAG4” technique and each of three alternative techniques, called “McIntosh Active-Region Class,” “Total Magnetic Flux,” and “Next MAG4.” We do this by using (1) the MAG4 database of magnetograms and major flare histories of sunspot active regions, (2) the NOAA table of the major-flare productivity of each of 60 McIntosh active-region classes of sunspot active regions, and (3) five technique performance metrics (Heidke Skill Score, True Skill Score, Percent Correct, Probability of Detection, and False Alarm Rate) evaluated from 2000 random two-by-two contingency tables obtained from the databases. We find that (1) Present MAG4 far outperforms both McIntosh Active-Region Class and Total Magnetic Flux, (2) Next MAG4 significantly outperforms Present MAG4, (3) the performance of Next MAG4 is insensitive to the forward and backward temporal windows used, in the range of one to a few days, and (4) forecasting from the free-energy proxy in combination with either any broad category of McIntosh active-region classes or any Mount Wilson active-region class gives no significant performance improvement over forecasting from the free-energy proxy alone (Present MAG4). Key Points Quantitative comparison of performance of pairs of forecasting techniques Next MAG4 forecasts major flares more accurately than Present MAG4 Present MAG4 forecast outperforms McIntosh AR Class and total magnetic flux PMID:26213517

  7. THOR Fluxgate Magnetometer (MAG)

    NASA Astrophysics Data System (ADS)

    Nakamura, Rumi; Eastwood, Jonathan; Magnes, Werner; Carr, Christopher, M.; O'Brien, Helen, L.; Narita, Yasuhito; K, Chen, Christopher H.; Berghofer, Gerhard; Valavanoglou, Aris; Delva, Magda; Plaschke, Ferdinand; Cupido, Emanuele; Soucek, Jan

    2017-04-01

    Turbulence Heating ObserveR (THOR) is the first mission ever flown in space dedicated to plasma turbulence. The fluxgate Magnetometer (MAG) measures the background to low frequency magnetic field. The high sensitivity measurements of MAG enable to characterize the nature of turbulent fluctuations as well as the large-scale context. MAG will provide the reference system for determining anisotropy of field fluctuations, pitch-angle and gyro-phase of particles. The design of the magnetometer consists of two tri-axial sensors and the related magnetometer electronics; the electronics are hosted on printed circuit boards in the common electronics box of the fields and wave processor (FWP). A fully redundant two- sensor system mounted on a common boom and the new miniaturized low noise design based on MMS and Solar Orbiter instruments enable accurate measurement throughout the region of interest for THOR science. The usage of the common electronics hosted by FWP guarantees to fulfill the required timing accuracy with other fields measurements. These improvements are important to obtain precise measurements of magnetic field, which is essential to estimate basic plasma parameters and correctly identify the spatial and temporal scales of the turbulence. Furthermore, THOR MAG provides high quality data with sufficient overlap with the Search Coil Magnetometer (SCM) in frequency space to obtain full coverage of the wave forms over all the frequencies necessary to obtain the full solar wind turbulence spectrum from MHD to kinetic range with sufficient accuracy. We discuss the role of MAG in THOR key science questions and present the new developments during Phase A such as the finalised instrument design, MAG relevant requirement, and new calibraion schemes.

  8. MAG4 Versus Alternative Techniques for Forecasting Active-Region Flare Productivity

    NASA Technical Reports Server (NTRS)

    Falconer, David A.; Moore, Ronald L.; Barghouty, Abdulnasser F.; Khazanov, Igor

    2014-01-01

    MAG4 is a technique of forecasting an active region's rate of production of major flares in the coming few days from a free-magnetic-energy proxy. We present a statistical method of measuring the difference in performance between MAG4 and comparable alternative techniques that forecast an active region's major-flare productivity from alternative observed aspects of the active region. We demonstrate the method by measuring the difference in performance between the "Present MAG4" technique and each of three alternative techniques, called "McIntosh Active-Region Class," "Total Magnetic Flux," and "Next MAG4." We do this by using (1) the MAG4 database of magnetograms and major-flare histories of sunspot active regions, (2) the NOAA table of the major-flare productivity of each of 60 McIntosh active-region classes of sunspot active regions, and (3) five technique-performance metrics (Heidke Skill Score, True Skill Score, Percent Correct, Probability of Detection, and False Alarm Rate) evaluated from 2000 random two-by-two contingency tables obtained from the databases. We find that (1) Present MAG4 far outperforms both McIntosh Active-Region Class and Total Magnetic Flux, (2) Next MAG4 significantly outperforms Present MAG4, (3) the performance of Next MAG4 is insensitive to the forward and backward temporal windows used, in the range of one to a few days, and (4) forecasting from the free-energy proxy in combination with either any broad category of McIntosh active-region classes or any Mount Wilson active-region class gives no significant performance improvement over forecasting from the free-energy proxy alone (Present MAG4).

  9. Preparation of 99Tcm-MAG3: no confirmation that sodium chloride injections from plastic containers affect radiochemical purity.

    PubMed

    Millar, A M; O'Brien, L M

    1998-05-01

    Reports have suggested that when sodium chloride injections from a plastic ampoule are used during the preparation of 99Tcm-mercaptoacetyltriglycine (99Tcm-MAG3), the radiochemical purity of the final product might be reduced. A study was therefore undertaken to examine the effect of sodium chloride injections from five manufacturers on the radiochemical purity and stability of 99Tcm-MAG3. One sodium chloride injection was supplied in a glass vial, three in plastic ampoules and one in a plastic infusion bag. Three batches of sodium chloride injections from each manufacturer were tested. The radiopharmaceutical was prepared at a radioactive concentration of 1.1 GBq in 10 ml according to the instructions of the manufacturer of TechneScan MAG3. Analysis of radiochemical purity was performed by high-performance liquid chromatography immediately after preparation and 6 h later. Using 95% as the minimum acceptable radiochemical purity, all the products were satisfactory over the 6 h test period. No manufacturer's sodium chloride injection was found to have a statistically significant effect on the radiochemical purity. Based on the 15 batches of sodium chloride injection tested, this study cannot confirm that sodium chloride injections from a plastic container affect the radiochemical purity of 99Tcm-MAG3. However, in view of the known sensitivity of some 99Tcm radiopharmaceuticals to external influences, it is probably good practice to test radiochemical purity when new batches of ancillary materials, such as sodium chloride injections, are introduced.

  10. The impact trajectory of asteroid 2008 TC3

    NASA Astrophysics Data System (ADS)

    Farnocchia, Davide; Jenniskens, Peter; Robertson, Darrel K.; Chesley, Steven R.; Dimare, Linda; Chodas, Paul W.

    2017-09-01

    The impact of asteroid 2008 TC3 was an unprecedented event-the first ever predicted impact of a near-Earth object. When it was first detected about 20 h before impact, 2008 TC3 was still farther away than the Moon. Once it was recognized as an impactor and announced as such, 2008 TC3 began to receive considerable attention from astronomical observers. Using the unprecedented dataset of nearly 900 astrometric observations and the latest observation debiasing and weighting techniques, we estimate the precise trajectory of 2008 TC3 and its impact ground track. At the entry point into the atmosphere, the 3-σ formal uncertainty in predicted position is an ellipse only 1.4 km × 0.15 km in size. The locations of the many meteorites recovered from the desert floor mark the asteroid's actual ground track and provide a unique opportunity to validate trajectory models. We find that the second-order zonal harmonics of the Earth gravity field moves the ground track by more than 1 km and the location along the ground track by more than 2 km, while non-zonal and higher order harmonics change the impact prediction by less than 20 m. The contribution of atmospheric drag to the trajectory of 2008 TC3 is similar to the numerical integration error level, a few meters, down to an altitude of 50 km. Integrating forward to lower altitudes and ignoring the break-up of 2008 TC3, atmospheric drag causes an along-track deviation that can be as large as a few kilometers at sea level.

  11. MagAO: status and science

    NASA Astrophysics Data System (ADS)

    Morzinski, Katie M.; Close, Laird M.; Males, Jared R.; Hinz, Phil M.; Esposito, Simone; Riccardi, Armando; Briguglio, Runa; Follette, Katherine B.; Pinna, Enrico; Puglisi, Alfio; Vezilj, Jennifer; Xompero, Marco; Wu, Ya-Lin

    2016-07-01

    "MagAO" is the adaptive optics instrument at the Magellan Clay telescope at Las Campanas Observatory, Chile. MagAO has a 585-actuator adaptive secondary mirror and 1000-Hz pyramid wavefront sensor, operating on natural guide stars from R-magnitudes of -1 to 15. MagAO has been in on-sky operation for 166 nights since installation in 2012. MagAO's unique capabilities are simultaneous imaging in the visible and infrared with VisAO and Clio, excellent performance at an excellent site, and a lean operations model. Science results from MagAO include the first ground-based CCD image of an exoplanet, demonstration of the first accreting protoplanets, discovery of a new wide-orbit exoplanet, and the first empirical bolometric luminosity of an exoplanet. We describe the status, report the AO performance, and summarize the science results. New developments reported here include color corrections on red guide stars for the wavefront sensor; a new field stop stage to facilitate VisAO imaging of extended sources; and eyepiece observing at the visible-light diffraction limit of a 6.5-m telescope. We also discuss a recent hose failure that led to a glycol coolant leak, and the recovery of the adaptive secondary mirror (ASM) after this recent (Feb. 2016) incident.

  12. MagLev Cobra: Test Facilities and Operational Experiments

    NASA Astrophysics Data System (ADS)

    Sotelo, G. G.; Dias, D. H. J. N.; de Oliveira, R. A. H.; Ferreira, A. C.; De Andrade, R., Jr.; Stephan, R. M.

    2014-05-01

    The superconducting MagLev technology for transportation systems is becoming mature due to the research and developing effort of recent years. The Brazilian project, named MagLev-Cobra, started in 1998. It has the goal of developing a superconducting levitation vehicle for urban areas. The adopted levitation technology is based on the diamagnetic and the flux pinning properties of YBa2Cu3O7-δ (YBCO) bulk blocks in the interaction with Nd-Fe-B permanent magnets. A laboratory test facility with permanent magnet guideway, linear induction motor and one vehicle module is been built to investigate its operation. The MagLev-Cobra project state of the art is presented in the present paper, describing some construction details of the new test line with 200 m.

  13. 3D Stagnation instabilities in MagLIF loads on the Z Generator

    NASA Astrophysics Data System (ADS)

    Jennings, Christopher

    2017-10-01

    Experiments with Magnetized Liner Inertial Fusion (MagLIF) loads have successfully demonstrated the premise of magnetized fusion. While these experiments are increasingly well diagnosed, many of the measurements (particularly during stagnation) are time integrated, limited in spatial resolution or require additional assumptions to interpret in the context of a structured, rapidly evolving system. As such, there is some ambiguity over what may be limiting performance. Poor laser coupling in preheating the fuel prior to implosion has been suggested as a mechanism. Mix of high Z contaminants that cool the fuel is also a significant concern. In addition, time integrated crystal imaging has shown significant structure in the final fuel assembly indicating potential disruption from instabilities. Understanding the balance between these degradation mechanisms is vital to progress with MagLif. We compare several sets of experimental data with synthetically generated data from systematically varied 3D resistive-MHD simulations to gain insight into the relative contributions of different degradation mechanisms. We demonstrate how some measurements strongly indicate disruption from liner material penetrating into the fuel at stagnation, and discuss the implications this has for how MagLif targets work and scale to larger drive currents. We then explore the extent to which different combinations of instability development, current delivery, high-Z mix into the fuel and initial laser deposition can be differentiated in our existing measurements. Better determining the dominant degradation mechanisms can directly influence the direction we take to improve performance, or our confidence in scaling these targets to higher currents. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology and Engineering Solutions of Sandia LLC, a wholly owned subsidiary of Honeywell International Inc. for the U.S. DoE's NNSA under contract DE-NA0003525.

  14. MAG-EPA resolves lung inflammation in an allergic model of asthma.

    PubMed

    Morin, C; Fortin, S; Cantin, A M; Rousseau, É

    2013-09-01

    Asthma is a chronic disease characterized by airways hyperresponsiveness, inflammation and airways remodelling involving reversible bronchial obstruction. Omega-3 fatty acids and their derivatives are known to reduce inflammation in several tissues including lung. The effects of eicosapentaenoic acid monoacylglyceride (MAG-EPA), a newly synthesized EPA derivative, were determined on the resolution of lung inflammation and airway hyperresponsiveness in an in vivo model of allergic asthma. Ovalbumin (OVA)-sensitized guinea-pigs were treated or not with MAG-EPA administered per os. Isometric tension measurements, histological analyses, homogenate preparation for Western blot experiments or total RNA extraction for RT-PCR were performed to assess the effect of MAG-EPA treatments. Mechanical tension measurements revealed that oral MAG-EPA treatments reduced methacholine (MCh)-induced bronchial hyperresponsiveness in OVA-sensitized guinea-pigs. Moreover, MAG-EPA treatments also decreased Ca(2+) hypersensitivity of bronchial smooth muscle. Histological analyses and leucocyte counts in bronchoalveolar lavages revealed that oral MAG-EPA treatments led to less inflammatory cell recruitment in the lung of OVA-sensitized guinea-pigs when compared with lungs from control animals. Results also revealed a reduction in mucin production and MUC5AC expression level in OVA-sensitized animals treated with MAG-EPA. Following MAG-EPA treatments, the transcript levels of pro-inflammatory markers such as IL-5, eotaxin, IL-13 and IL-4 were markedly reduced. Moreover, per os MAG-EPA administrations reduced COX2 over-expression in OVA-sensitized animals. We demonstrate that MAG-EPA reduces airway hyperresponsiveness and lung inflammation in OVA-sensitized animals, a finding consistent with a decrease in IL-4, IL-5, IL-13, COX-2 and MUC5AC expression levels in the lung. The present data suggest that MAG-EPA represents a new potential therapeutic strategy for resolving inflammation in allergic

  15. Implementation of cargo MagLev in the United States

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rose, Chris R; Peterson, Dean E; Leung, Eddie M

    2008-01-01

    Numerous studies have been completed in the United States, but no commercial MagLev systems have been deployed. Outside the U.S., MagLev continues to attract funding for research, development and implementation. A brief review of recent global developments in MagLev technology is given followed by the status of MagLev in the U.S. The paper compares the cost of existing MagLev systems with other modes of transport, notes that the near-term focus of MagLev development in the U.S. should be for cargo, and suggests that future MagLev systems should be for very high speed cargo. The Los Angeles to Port of Losmore » Angeles corridor is suggested as a first site for implementation. The benefits of MagLev are described along with suggestions on how to obtain funding.« less

  16. Anti-MAG antibodies in 202 patients: clinicopathological and therapeutic features.

    PubMed

    Svahn, Juliette; Petiot, Philippe; Antoine, Jean-Christophe; Vial, Christophe; Delmont, Emilien; Viala, Karine; Steck, Andreas J; Magot, Armelle; Cauquil, Cecile; Zarea, Aline; Echaniz-Laguna, Andoni; Iancu Ferfoglia, Ruxandra; Gueguen, Antoine; Magy, Laurent; Léger, Jean-Marc; Kuntzer, Thierry; Ferraud, Karine; Lacour, Arnaud; Camdessanché, Jean-Philippe

    2018-05-01

    To assess the clinicopathological and therapeutic features of patients with low (≥1000 to <10 000 Bühlmann Titre Units) (BTU), medium (10 000-70 000) or high (≥70 000) anti-myelin-associated glycoprotein (anti-MAG) antibody titres. We retrospectively and prospectively analysed standardised report forms and medical records of 202 patients from 14 neuromuscular centres. Mean age at onset and mean time between symptom onset to last follow-up were respectively 62.6 years (25-91.4) and 8.4 years (0.3-33.3). Anti-MAG antibody titres at diagnosis were low, medium or high in 11%, 51% and 38% of patients. Patients presented with monoclonal gammopathy of undetermined significance in 68% of cases. About 17% of patients presented with 'atypical' clinical phenotype independently of anti-MAG titres, including acute or chronic sensorimotor polyradiculoneuropathies (12.4%), and asymmetric or multifocal neuropathy (3%). At the most severe disease stage, 22.4% of patients were significantly disabled. Seventy-eight per cent of patients received immunotherapies. Transient clinical worsening was observed in 12% of patients treated with rituximab (11/92). Stabilisation after rituximab treatment during the 7-12-month follow-up period was observed in 29% of patients. Clinical response to rituximab during the 6-month and/or 7-12-month follow-up period was observed in 31.5% of patients and correlated with anti-MAG titre ≥10 000 BTU. Our study highlights the extended clinical spectrum of patients with anti-MAG neuropathy, which appears unrelated to antibody titre. Besides, it may also suggest beneficial use of rituximab in the early phase of anti-MAG neuropathy. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. The Magnetics Information Consortium (MagIC)

    NASA Astrophysics Data System (ADS)

    Johnson, C.; Constable, C.; Tauxe, L.; Koppers, A.; Banerjee, S.; Jackson, M.; Solheid, P.

    2003-12-01

    The Magnetics Information Consortium (MagIC) is a multi-user facility to establish and maintain a state-of-the-art relational database and digital archive for rock and paleomagnetic data. The goal of MagIC is to make such data generally available and to provide an information technology infrastructure for these and other research-oriented databases run by the international community. As its name implies, MagIC will not be restricted to paleomagnetic or rock magnetic data only, although MagIC will focus on these kinds of information during its setup phase. MagIC will be hosted under EarthRef.org at http://earthref.org/MAGIC/ where two "integrated" web portals will be developed, one for paleomagnetism (currently functional as a prototype that can be explored via the http://earthref.org/databases/PMAG/ link) and one for rock magnetism. The MagIC database will store all measurements and their derived properties for studies of paleomagnetic directions (inclination, declination) and their intensities, and for rock magnetic experiments (hysteresis, remanence, susceptibility, anisotropy). Ultimately, this database will allow researchers to study "on the internet" and to download important data sets that display paleo-secular variations in the intensity of the Earth's magnetic field over geological time, or that display magnetic data in typical Zijderveld, hysteresis/FORC and various magnetization/remanence diagrams. The MagIC database is completely integrated in the EarthRef.org relational database structure and thus benefits significantly from already-existing common database components, such as the EarthRef Reference Database (ERR) and Address Book (ERAB). The ERR allows researchers to find complete sets of literature resources as used in GERM (Geochemical Earth Reference Model), REM (Reference Earth Model) and MagIC. The ERAB contains addresses for all contributors to the EarthRef.org databases, and also for those who participated in data collection, archiving and

  18. Spectroscopic Characterization of Aqua [ fac-Tc(CO)3]+ Complexes at High Ionic Strength.

    PubMed

    Chatterjee, Sayandev; Hall, Gabriel B; Engelhard, Mark H; Du, Yingge; Washton, Nancy M; Lukens, Wayne W; Lee, Sungsik; Pearce, Carolyn I; Levitskaia, Tatiana G

    2018-06-18

    Understanding fundamental Tc chemistry is important to both the remediation of nuclear waste and the reprocessing of nuclear fuel; however, current knowledge of the electronic structure and spectral signatures of low-valent Tc compounds significantly lags behind the remainder of the d-block elements. In particular, identification and treatment of Tc speciation in legacy nuclear waste is challenging due to the lack of reference data especially for Tc compounds in the less common oxidation states (I-VI). In an effort to establish a spectroscopic library corresponding to the relevant conditions of extremely high ionic strength typical for the legacy nuclear waste, compounds with the general formula of [ fac-Tc(CO) 3 (OH 2 ) 3- n (OH) n ] 1- n (where n = 0-3) were examined by a range of spectroscopic techniques including 99 Tc/ 13 C NMR, IR, XPS, and XAS. In the series of monomeric aqua species, stepwise hydrolysis results in the increase of the Tc metal center electron density and corresponding progressive decrease of the Tc-C bond distances, Tc electron binding energies, and carbonyl stretching frequencies in the order [ fac-Tc(CO) 3 (OH 2 ) 3 ] + > [ fac-Tc(CO) 3 (OH 2 ) 2 (OH)] > [ fac-Tc(CO) 3 (OH 2 )(OH) 2 ] - . These results correlate with established trends of the 99 Tc upfield chemical shift and carbonyl 13 C downfield chemical shift. The lone exception is [ fac-Tc(CO) 3 (OH)] 4 which exhibits a comparatively low electron density at the metal center attributed to the μ 3 -bridging nature of the - OH ligands causing less σ-donation and no π-donation. This work also reports the first observations of these compounds by XPS and [ fac-Tc(CO) 3 Cl 3 ] 2- by XAS. The unique and distinguishable spectral features of the aqua [ fac-Tc(CO) 3 ] + complexes lay the foundation for their identification in the complex aqueous matrixes.

  19. A National MagLev Transportation System

    NASA Technical Reports Server (NTRS)

    Wright, Michael R.

    2003-01-01

    The case for a national high-speed magnetic-levitation (MagLev) transportation system is presented. Focus is on current issues facing the country, such as national security, the economy, transportation, technology, and the environment. NASA s research into MagLev technology for launch assist is also highlighted. Further, current socio-cultural norms regarding motor-vehicle-based transportation systems are questioned in light of the problems currently facing the U.S. The multidisciplinary benefits of a long-distance MagLev system support the idea that such a system would be an important element of a truly multimodal U.S. transportation infrastructure.

  20. Tangential gunshot wound with MagSafe ammunition.

    PubMed

    Rapkiewicz, Amy V; Tamburri, Robert; Basoa, Mark E; Catanese, Charles A

    2005-09-01

    MagSafe ammunition is a type of unconventional prefragmented ammunition. A fatal tangential gunshot wound involving MagSafe ammunition is presented. The ammunition and wound characteristics are discussed.

  1. Novel 99mTc(III)-azide complexes [99mTc(N3)(CDO)(CDOH)2B-R] (CDOH2=cyclohexanedione dioxime) as potential radiotracers for heart imaging.

    PubMed

    Liu, Min; Zheng, Yumin; Avcibasi, Ugur; Liu, Shuang

    2016-11-01

    In this study, novel 99m Tc(III)-azide complexes [ 99m Tc(N 3 )(CDO)(CDOH) 2 B-R] ( 99m Tc-ISboroxime-N 3 : R=IS; 99m Tc-MPboroxime-N 3 : R=MP; 99m Tc-PAboroxime-N 3 : R=PA; 99m Tc-PYboroxime-N 3 : R=PY; and 99m Tc-Uboroxime-N 3 : R=5U) were evaluated as heart imaging agents. Complexes [ 99m Tc(N 3 )(CDO)(CDOH) 2 B-R] (R=IS, MP, PA, PY and 5U) were prepared by ligand exchange between NaN 3 and [ 99m TcCl(CDO)(CDOH) 2 B-R]. Biodistribution and imaging studies were carried out in Sprague-Dawley rats. Image quantification was performed to compare their initial heart uptake and myocardial retention. 99m Tc-ISboroxime-N 3 , 99m Tc-PYboroxime-N 3 and 99m Tc-Uboroxime-N 3 were prepared with high RCP (93-98%) while the RCP of 99m Tc-MPboroxime-N 3 and 99m Tc-PAboroxime-N 3 was 80-85%. The myocardial retention curves of 99m Tc-ISboroxime-N 3 , 99m Tc-PYboroxime-N 3 and 99m Tc-Uboroxime-N 3 were best fitted to the bi-exponential decay function. The half-time of the fast component was 1.6±0.4min for 99m Tc-ISboroxime-N 3 , 0.7±0.1min for 99m Tc-PYboroxime-N 3 and 0.9±0.4min for 99m Tc-Uboroxime-N 3 . The 2-min heart uptake from biodistribution studies followed the ranking order of 99m Tc-ISboroxime-N 3 (3.60±0.68%ID/g)> 99m Tc-PYboroxime-N 3 (2.35±0.37%ID/g)≫ 99m Tc-Uboroxime-N 3 (1.29±0.06%ID/g). 99m Tc-ISboroxime-N 3 had the highest 2-min heart uptake among 99m Tc radiotracers revaluated in SD rats. High quality SPECT images were obtained with the right and left ventricular walls being clearly delineated. The best image acquisition window was 0-5min for 99m Tc-ISboroxime-N 3 . Both azide coligand and boronate caps had significant impact on the heart uptake and myocardial retention of complexes [ 99m Tc(N 3 )(CDO)(CDOH) 2 B-R]. Among the radiotracers evaluated in SD rats, 99m Tc-ISboroxime-N 3 has the highest initial heart uptake with the heart retention comparable to that of 99m Tc-Teboroxime. 99m Tc-ISboroxime-N 3 is a promising alternative to 99m Tc-Teboroxime for

  2. 99mTc-3P4-RGD2 Scintimammography in the Assessment of Breast Lesions: Comparative Study with 99mTc-MIBI

    PubMed Central

    Gao, Shi; Ji, Tiefeng; Wen, Qiang; Song, Yan; Zhu, Lei; Xu, Zheli; Liu, Lin

    2014-01-01

    Purpose To compare the potential application of 99mTc-3P-Arg-Gly-Asp (99mTc-3P4-RGD2) scintimammography (SMM) and 99mTc-methoxyisobutylisonitrile (99mTc-MIBI) SMM for the differentiation of malignant from benign breast lesions. Method Thirty-six patients with breast masses on physical examination and/or suspicious mammography results that required fine needle aspiration cytology biopsy (FNAB) were included in the study. 99mTc-3P4-RGD2 and 99mTc-MIBI SMM were performed with single photon emission computed tomography (SPECT) at 60 min and 20 min respectively after intravenous injection of 738±86 MBq radiotracers on a separate day. Images were evaluated by the tumor to non-tumor localization ratios (T/NT). Receiver operating characteristic (ROC) curve analysis was performed on each radiotracer to calculate the cut-off values of quantitative indices and to compare the diagnostic performance for the ability to differentiate malignant from benign diseases. Results The mean T/NT ratio of 99mTc-3P4-RGD2 in malignant lesions was significantly higher than that in benign lesions (3.54±1.51 vs. 1.83±0.98, p<0.001). The sensitivity, specificity, and accuracy of 99mTc-3P4-RGD2 SMM were 89.3%, 90.9% and 89.7%, respectively, with a T/NT cut-off value of 2.40. The mean T/NT ratio of 99mTc-MIBI in malignant lesions was also significantly higher than that in benign lesions (2.86±0.99 vs. 1.51±0.61, p<0.001). The sensitivity, specificity and accuracy of 99mTc-MIBI SMM were 87.5%, 72.7% and 82.1%, respectively, with a T/NT cut-off value of 1.45. According to the ROC analysis, the area under the curve for 99mTc-3P4-RGD2 SMM (area = 0.851) was higher than that for 99mTc-MIBI SMM (area = 0.781), but the statistical difference was not significant. Conclusion 99mTc-3P4-RGD2 SMM does not provide any significant advantage over the established 99mTc-MIBI SMM for the detection of primary breast cancer. The T/NT ratio of 99mTc-3P4-RGD2 SMM was significantly higher than that of 99mTc

  3. UVB-induced nuclear translocation of TC-PTP by AKT/14-3-3σ axis inhibits keratinocyte survival and proliferation.

    PubMed

    Kim, Mihwa; Morales, Liza D; Baek, Minwoo; Slaga, Thomas J; DiGiovanni, John; Kim, Dae Joon

    2017-10-31

    Understanding protein subcellular localization is important to determining the functional role of specific proteins. T-cell protein tyrosine phosphatase (TC-PTP) contains bipartite nuclear localization signals (NLSI and NLSII) in its C-terminus. We previously have demonstrated that the nuclear form of TC-PTP (TC45) is mainly localized to the cytoplasm in keratinocytes and it is translocated to the nucleus following UVB irradiation. Here, we report that TC45 is translocated by an AKT/14-3-3σ-mediated mechanism in response to UVB exposure, resulting in increased apoptosis and decreased keratinocyte proliferation. We demonstrate that UVB irradiation increased phosphorylation of AKT and induced nuclear translocation of 14-3-3σ and TC45. However, inhibition of AKT blocked nuclear translocation of TC45 and 14-3-3σ. Site-directed mutagenesis of 14-3-3σ binding sites within TC45 showed that a substitution at Threonine 179 (TC45/T179A) effectively blocked UVB-induced nuclear translocation of ectopic TC45 due to the disruption of the direct binding between TC45 and 14-3-3σ. Overexpression of TC45/T179A in keratinocytes resulted in a decrease of UVB-induced apoptosis which corresponded to an increase in nuclear phosphorylated STAT3, and cell proliferation was higher in TC45/T179A-overexpressing keratinocytes compared to control keratinocytes following UVB irradiation. Furthermore, deletion of TC45 NLSII blocked its UVB-induced nuclear translocation, indicating that both T179 and NLSII are required. Taken together, our findings suggest that AKT and 14-3-3σ cooperatively regulate TC45 nuclear translocation in a critical step of an early protective mechanism against UVB exposure that signals the deactivation of STAT3 in order to promote keratinocyte cell death and inhibit keratinocyte proliferation.

  4. Jule from the fish Xiphophorus is the first complete vertebrate Ty3/Gypsy retrotransposon from the Mag family.

    PubMed

    Volff, J N; Körting, C; Altschmied, J; Duschl, J; Sweeney, K; Wichert, K; Froschauer, A; Schartl, M

    2001-02-01

    Jule is the second complete long-terminal-repeat (LTR) Ty3/Gypsy retrotransposon identified to date in vertebrates. Jule, first isolated from the poeciliid fish Xiphophorus maculatus, is 4.8 kb in length, is flanked by two 202-bp LTRs, and encodes Gag (structural core protein) and Pol (protease, reverse transcriptase, RNase H, and integrase, in that order) but no envelope. There are three to four copies of Jule per haploid genome in X. maculatus. Two of them are located in a subtelomeric region of the sex chromosomes, where they are associated with the Xmrk receptor tyrosine kinase genes, of which oncogenic versions are responsible for the formation of hereditary melanoma in Xiphophorus. One almost intact copy of Jule was found in the first intron of the X-chromosomal allele of the Xmrk proto-oncogene, and a second, more corrupted copy is present only 56 nt downstream of the polyadenylation signal of the Xmrk oncogene. Jule-related elements were detected by Southern blot hybridization with less than 10 copies per haploid genome in numerous other poeciliids, as well as in more divergent fishes, including the medakafish Oryzias latipes and the tilapia Oreochromis niloticus. Database searches also identified Jule-related sequences in the zebrafish Danio rerio and in both genome project pufferfishes, Fugu rubripes and Tetraodon nigroviridis. Phylogenetic analysis revealed that Jule is the first member of the Mag family of Ty3/Gypsy retrotransposons described to date in vertebrates. This family includes the silkworm Mag and sea urchin SURL retrotransposons, as well as sequences from the nematode Caenorhabditis elegans. Additional related elements were identified in the genomes of the malaria mosquito Anopheles gambiae and the nematode Ascaris lumbricoides. Phylogeny of Mag-related elements suggested that the Mag family of retrotransposons is polyphyletic and is constituted of several ancient lineages that diverged before their host genomes more than 600 MYA.

  5. Heterogeneity of Polyneuropathy Associated with Anti-MAG Antibodies

    PubMed Central

    Magy, Laurent; Kaboré, Raphaël; Mathis, Stéphane; Lebeau, Prisca; Ghorab, Karima; Caudie, Christiane; Vallat, Jean-Michel

    2015-01-01

    Polyneuropathy associated with IgM monoclonal gammopathy and anti-myelin associated glycoprotein (MAG) antibodies is an immune-mediated demyelinating neuropathy. The pathophysiology of this condition is likely to involve anti-MAG antibody deposition on myelin sheaths of the peripheral nerves and it is supposed to be distinct from chronic inflammatory demyelinating neuropathy (CIDP), another immune-mediated demyelinating peripheral neuropathy. In this series, we have retrospectively reviewed clinical and laboratory findings from 60 patients with polyneuropathy, IgM gammopathy, and anti-MAG antibodies. We found that the clinical picture in these patients is highly variable suggesting a direct link between the monoclonal gammopathy and the neuropathy. Conversely, one-third of patients had a CIDP-like phenotype on electrodiagnostic testing and this was correlated with a low titer of anti-MAG antibodies and the absence of widening of myelin lamellae. Our data suggest that polyneuropathy associated with anti-MAG antibodies is less homogeneous than previously said and that the pathophysiology of the condition is likely to be heterogeneous as well with the self-antigen being MAG in most of the patients but possibly being another component of myelin in the others. PMID:26065001

  6. Probing circumplanetary disks with MagAO and ALMA

    NASA Astrophysics Data System (ADS)

    Wu, Ya-Lin

    2018-01-01

    The dedication of the Magellan Adaptive Optics (MagAO) on the 6.5 m Clay Telescope has opened a new era in high-contrast imaging. Its unique diffraction-limited wavelengths of 0.6 to 1 micron helps to probe circumplanetary disks by measuring the amount of dust reddening as well as by searching for the strongest gas accretion indicator H-alpha (0.65 micron). Using MagAO, I found that two wide-orbit planetary-mass companions CT Cha B and 1RXS 1609 B have a significant dust extinction of Av ~ 3 to 5 mag likely from their disks. For GQ Lup B, I found that it is actively accreting material from its disk and emitting strong H-alpha emission. My research with MagAO demonstrates that circumplanetary disks could be ubiquitous among young giant planets. I later carried out a survey using ALMA to image accretion disks around several wide planet-mass companions at 1.3 mm continuum and CO (2-1). This is the first systematic study aiming to measure the size, mass, and structure of planetary disks. However, except for FW Tau C (which was shown to actually be a low-mass star from the dynamical mass measurement) no disks around the companions were found in my ALMA survey. This surprising null result implies that circumplanetary disks are much more compact and denser than expected, so they are faint and optically thick in the radio wavelengths. Therefore, mid- to far-infrared may be more favorable to characterize disk properties. The MIRI camera on the JWST can test this compact optically-thick disk hypothesis by probing disk thermal emission between 10 and 25 micron.

  7. The fully synthetic MAG-Tn3 therapeutic vaccine containing the tetanus toxoid-derived TT830-844 universal epitope provides anti-tumor immunity.

    PubMed

    Laubreton, Daphné; Bay, Sylvie; Sedlik, Christine; Artaud, Cécile; Ganneau, Christelle; Dériaud, Edith; Viel, Sophie; Puaux, Anne-Laure; Amigorena, Sebastian; Gérard, Catherine; Lo-Man, Richard; Leclerc, Claude

    2016-03-01

    Malignant transformations are often associated with aberrant glycosylation processes that lead to the expression of new carbohydrate antigens at the surface of tumor cells. Of these carbohydrate antigens, the Tn antigen is particularly highly expressed in many carcinomas, especially in breast carcinoma. We designed MAG-Tn3, a fully synthetic vaccine based on three consecutive Tn moieties that are O-linked to a CD4+ T cell epitope, to induce anti-Tn antibody responses that could be helpful for therapeutic vaccination against cancer. To ensure broad coverage within the human population, the tetanus toxoid-derived peptide TT830-844 was selected as a T-helper epitope because it can bind to various HLA-DRB molecules. We showed that the MAG-Tn3 vaccine, which was formulated with the GSK proprietary immunostimulant AS15 and designed for human cancer therapy, is able to induce an anti-Tn antibody response in mice of various H-2 haplotypes, and this response correlates with the ability to induce a specific T cell response against the TT830-844 peptide. The universality of the TT830-844 peptide was extended to new H-2 and HLA-DRB molecules that were capable of binding this T cell epitope. Finally, the MAG-Tn3 vaccine was able to induce anti-Tn antibody responses in cynomolgus monkeys, which targeted Tn-expressing tumor cells and mediated tumor cell death both in vitro and in vivo. Thus, MAG-Tn3 is a highly promising anticancer vaccine that is currently under evaluation in a phase I clinical trial.

  8. RW Per - Nodal motion changes its amplitude by 1.4 mag

    NASA Technical Reports Server (NTRS)

    Schaefer, Bradley E.; Fried, Robert E.

    1991-01-01

    RW Per was found to have large secular changes in its eclipse amplitude. In blue light, for example, the amplitude was 3.2 mag in the early 1900s, 2.2 mag in the late 1960s, and 1.75 mag in 1990. Throughout this time, the brightness at maximum was constant in all colors. It is shown that the only possible explanation is nodal motion, where the inclination varies with a period of roughly 100,000 yr. The nodal motion is caused by a third star, for which the light curve, the colors, and the O - C curve already provide evidence. Thus, RW Per is only the fourth known star with large changes of eclipse amplitude and is only the second example of nodal motion.

  9. A preliminary study of the thermal measurement with nMAG gel dosimeter by MRI

    NASA Astrophysics Data System (ADS)

    Chuang, Chun-Chao; Shao, Chia-Ho; Shih, Cheng-Ting; Yeh, Yu-Chen; Lu, Cheng-Chang; Chuang, Keh-Shih; Wu, Jay

    2014-11-01

    The methacrylic acid (nMAG) gel dosimeter is an effective tool for 3-dimensional quality assurance of radiation therapy. In addition to radiation induced polymerization effects, the nMAG gel also responds to temperature variation. In this study, we proposed a new method to evaluate the thermal response in thermal therapy using nMAG gel and magnetic resonance image (MRI) scans. Several properties of nMAG have been investigated including the R2 relaxation rate, temperature sensitivity, and temperature linearity of the thermal dose response. nMAG was heated by the double-boiling method in the range of 37-45 °C. MRI scans were performed with the head coil receiver. The temperature to R2 response curve was analyzed and simple linear regression was performed with an R-square value of 0.9835. The measured data showed a well inverse linear relationship between R2 and temperature. We conclude that the nMAG polymer gel dosimeter shows great potential as a technique to evaluate the temperature rise during thermal surgery.

  10. Improved synthesis and biological evaluation of Tc-99m radiolabeled AMO for miRNA imaging in tumor xenografts.

    PubMed

    Kang, Lei; Fan, Zhongyi; Sun, Hongwei; Feng, Yingying; Ma, Chao; Yan, Ping; Zhang, Chunli; Ma, Huan; Hao, Pan; Chen, Xueqi; Zheng, Zhibing; Xu, Xiaojie; Wang, Rongfu

    2015-01-01

    MicroRNAs (miRNAs) have been considered as important biomarkers for malignant tumors. In this study, we introduced an improved (99m)Tc labeling method for noninvasive visualization of overexpressed miRNAs in tumor-bearing mice. Anti-miRNA-21 oligonucleotide (AMO) with partial 2'-O-methyl and phosphorothioate modification was designed and chemically synthesized. After conjugated with NHS-MAG3, AMO was labeled with (99m)Tc. Optimization was made to shorten reaction time and to improve labeling efficiency. Labeling efficiency was 97%, and specific activity was 2.78 MBq/ng. During 12 h, (99m)Tc-AMO showed no significant degradation by gel electrophoresis. Its radiochemical purity was stable, between 95.8% and 99.1%. Further, (99m)Tc-AMO decreased the level of miR-21 and increased the expression of PTEN protein at cellular level, shown by qRT-PCR and Western blot. Fluorescent protein labeled AMO displayed specific distribution and good stability in tumor cells. After the administration in tumor-bearing mice, (99m)Tc-AMO showed more radioactive uptake in the miR-21 over-expressed tumors than scramble control. Biodistribution results further proved the significant difference of tumor uptake between (99m)Tc-AMO and (99m)Tc-control. Therefore, this study presents an improved method with shorten time to prepare a (99m)Tc radiolabeled AMO. In addition, it supports the role of (99m)Tc-AMO for noninvasive visualization of miR-21 in malignant tumors. Copyright © 2015 John Wiley & Sons, Ltd.

  11. Mag-seeding of rat bone marrow stromal cells into porous hydroxyapatite scaffolds for bone tissue engineering.

    PubMed

    Shimizu, Kazunori; Ito, Akira; Honda, Hiroyuki

    2007-09-01

    Bone tissue engineering has been investigated as an alternative strategy for autograft transplantation. In the process of tissue engineering, cell seeding into three-dimensional (3-D) scaffolds is the first step for constructing 3-D tissues. We have proposed a methodology of cell seeding into 3-D porous scaffolds using magnetic force and magnetite nanoparticles, which we term Mag-seeding. In this study, we applied this Mag-seeding technique to bone tissue engineering using bone marrow stromal cells (BMSCs) and 3-D hydroxyapatite (HA) scaffolds. BMSCs were magnetically labeled with our original magnetite cationic liposomes (MCLs) having a positive surface charge to improve adsorption to cell surface. Magnetically labeled BMSCs were seeded onto a scaffold, and a 1-T magnet was placed under the scaffold. By using Mag-seeding, the cells were successfully seeded into the internal space of scaffolds with a high cell density. The cell seeding efficiency into HA scaffolds by Mag-seeding was approximately threefold larger than that by static-seeding (conventional method, without a magnet). After a 14-d cultivation period using the osteogenic induction medium by Mag-seeding, the level of two representative osteogenic markers (alkaline phosphatase and osteocalcin) were significantly higher than those by static-seeding. These results indicated that Mag-seeding of BMSCs into HA scaffolds is an effective approach to bone tissue engineering.

  12. TcNPR3 from Theobroma cacao functions as a repressor of the pathogen defense response

    PubMed Central

    2013-01-01

    Background Arabidopsis thaliana (Arabidopsis) NON-EXPRESSOR OF PR1 (NPR1) is a transcription coactivator that plays a central role in regulating the transcriptional response to plant pathogens. Developing flowers of homozygous npr3 mutants are dramatically more resistant to infection by the pathogenic bacterium Pseudomonas syringae, suggesting a role of NPR3 as a repressor of NPR1-mediated defense response with a novel role in flower development. Results We report here the characterization of a putative NPR3 gene from the tropical tree species Theobroma cacao (TcNPR3). Like in Arabidopsis, TcNPR3 was constitutively expressed across a wide range of tissue types and developmental stages but with some differences in relative levels compared to Arabidopsis. To test the function of TcNPR3, we performed transgenic complementation analysis by introducing a constitutively expressing putative TcNPR3 transgene into an Arabidopsis npr3 mutant. TcNPR3 expressing Arabidopsis plants were partially restored to the WT pathogen phenotype (immature flowers susceptible to bacterial infection). To test TcNPR3 function directly in cacao tissues, a synthetic microRNA targeting TcNPR3 mRNA was transiently expressed in cacao leaves using an Agrobacterium-infiltration method. TcNPR3 knock down leaf tissues were dramatically more resistance to infection with Phytophthora capsici in a leaf bioassay, showing smaller lesion sizes and reduced pathogen replication. Conclusions We conclude that TcNPR3 functions similar to the Arabidopsis NPR3 gene in the regulation of the cacao defense response. Since TcNPR3 did not show a perfect complementation of the Arabidopsis NPR3 mutation, the possibility remains that other functions of TcNPR3 remain to be found. This novel knowledge can contribute to the breeding of resistant cacao varieties against pathogens through molecular markers based approaches or biotechnological strategies. PMID:24314063

  13. TcNPR3 from Theobroma cacao functions as a repressor of the pathogen defense response.

    PubMed

    Shi, Zi; Zhang, Yufan; Maximova, Siela N; Guiltinan, Mark J

    2013-12-06

    Arabidopsis thaliana (Arabidopsis) NON-EXPRESSOR OF PR1 (NPR1) is a transcription coactivator that plays a central role in regulating the transcriptional response to plant pathogens. Developing flowers of homozygous npr3 mutants are dramatically more resistant to infection by the pathogenic bacterium Pseudomonas syringae, suggesting a role of NPR3 as a repressor of NPR1-mediated defense response with a novel role in flower development. We report here the characterization of a putative NPR3 gene from the tropical tree species Theobroma cacao (TcNPR3). Like in Arabidopsis, TcNPR3 was constitutively expressed across a wide range of tissue types and developmental stages but with some differences in relative levels compared to Arabidopsis. To test the function of TcNPR3, we performed transgenic complementation analysis by introducing a constitutively expressing putative TcNPR3 transgene into an Arabidopsis npr3 mutant. TcNPR3 expressing Arabidopsis plants were partially restored to the WT pathogen phenotype (immature flowers susceptible to bacterial infection). To test TcNPR3 function directly in cacao tissues, a synthetic microRNA targeting TcNPR3 mRNA was transiently expressed in cacao leaves using an Agrobacterium-infiltration method. TcNPR3 knock down leaf tissues were dramatically more resistance to infection with Phytophthora capsici in a leaf bioassay, showing smaller lesion sizes and reduced pathogen replication. We conclude that TcNPR3 functions similar to the Arabidopsis NPR3 gene in the regulation of the cacao defense response. Since TcNPR3 did not show a perfect complementation of the Arabidopsis NPR3 mutation, the possibility remains that other functions of TcNPR3 remain to be found. This novel knowledge can contribute to the breeding of resistant cacao varieties against pathogens through molecular markers based approaches or biotechnological strategies.

  14. Evaluation of interobserver variability of parenchymal phase of Tc-99m mercaptoacetyltriglycine and Tc-99m dimercaptosuccinic acid renal scintigraphy

    PubMed Central

    Erdoğan, Zeynep; Abdülrezzak, Ümmühan; Silov, Güler; Özdal, Ayşegül; Turhal, Özgül

    2014-01-01

    Objective: The aim of this study was to investigate the variability in the interpretation of parenchymal abnormalities and to assess the differences in interpretation of routine renal scintigraphic findings on posterior view of technetium-99m dimercaptosuccinic acid (pvDMSA) scans and parenchymal phase of technetium-99m mercaptoacetyltriglycine (ppMAG3) scans by using standard criterions to make standardization and semiquantitative evaluation and to have more accurately correlation. Materials and Methods: Two experienced nuclear medicine physicians independently interpreted pvDMSA scans of 204 and ppMAG3 scans of 102 pediatric patients, retrospectively. Comparisons were made by visual inspection of pvDMSA scans, and ppMAG3 scans by using a grading system modified from Itoh et al. According to this, anatomical damage of the renal parenchyma was classified into six types: Grade 0-V. In the calculation of the agreement rates, Kendall correlation (tau-b) analysis was used. Results: According to our findings, excellent agreement was found for DMSA grade readings (DMSA-GR) (tau-b = 0.827) and good agreement for MAG3 grade readings (MAG3-GR) (tau-b = 0.790) between two observers. Most of clear parenchymal lesions detected on pvDMSA scans and ppMAG3 scans identified by observers equally. Studies with negative or minimal lesions reduced correlation degrees for both DMSA-GR and MAG3-GR. Conclusion: Our grading system can be used for standardization of the reports. We conclude that standardization of criteria and terminology in the interpretations may result in higher interobserver consistency, also improve low interobserver reproducibility and objectivity of renal scintigraphy reports. PMID:24761059

  15. In situ Spectroscopic Analysis and Quantification of [Tc(CO)3]+ in Hanford Tank Waste.

    PubMed

    Branch, Shirmir D; French, Amanda D; Lines, Amanda M; Soderquist, Chuck Z; Rapko, Brian M; Heineman, William R; Bryan, Samuel A

    2018-06-12

    The quantitative conversion of non-pertechnetate [Tc(CO)3]+ species in nuclear waste storage tank 241-AN-102 at the Hanford Site is demonstrated. A waste sample containing the [Tc(CO)3]+ species is added to a developer solution that rapidly converts the non-emissive species into a luminescent complex, which is detected spectroscopically. This method was first demonstrated using a [Tc(CO)3]+ sample non-waste containing matrix to determine a detection limit (LOD), resulting in a [Tc(CO)3]+ LOD of 2.20 × 10-7 M, very near the LOD of the independently synthesized standard (2.10 × 10-7 M). The method was then used to detect [Tc(CO)3]+ in a simulated waste using the standard addition method, resulting in a [Tc(CO)3]+ concentration of 1.89 × 10-5 M (within 27.7% of the concentration determined by β- liquid scintillation counting). Three samples from 241-AN-102 were tested by the standard addition method: (1) a 5 M Na adjusted fraction, (2) a fraction depleted of 137Cs, (3) and an acid-stripped eluate. The concentrations of [Tc(CO)3]+ in these fractions were determined to be 9.90 × 10-6 M (1), 0 M (2), and 2.46 × 10-6 M (3), respectively. The concentration of [Tc(CO)3]+ in the as-received AN-102 tank waste supernatant was determined to be 1.84 × 10-5 M.

  16. The Phosphatidylinositol 3-kinase Class III Complex Containing TcVps15 and TcVps34 Participates in Autophagy in Trypanosoma cruzi.

    PubMed

    Schoijet, Alejandra C; Sternlieb, Tamara; Alonso, Guillermo D

    2017-05-01

    Autophagy is a degradative process by which eukaryotic cells digest their own components to provide aminoacids that may function as energy source under nutritional stress conditions. There is experimental evidence for autophagy in parasitic protists belonging to the family Trypanosomatidae. However, few proteins implicated in this process have been characterized so far in these parasites. Moreover, it has been shown that autophagy is involved in Trypanosoma cruzi differentiation and thus might have a role in pathogenicity. Here, we report the cloning and biochemical characterization of TcVps15. In addition, we demonstrate that TcVps15 interact with the PI3K TcVps34 and that both proteins associate with cellular membranes. Under nutritional stress conditions, TcVps15 and TcVps34 modify their subcellular distribution showing a partial co-localization in autophagosomes with TcAtg8.1 and using an active site TcVps15-mutated version (TcVps15-K219D-HA) we demonstrated that this relocalization depends on the TcVps15 catalytic activity. Overexpression of TcVps15-HA and TcVps15-K219D-HA also leads to increased accumulation of monodansylcadaverine (MDC) in autophagic vacuoles under nutritional stress conditions compared to wild-type cells. In addition, the MDC-specific activity shows to be significantly higher in TcVps15-HA overexpressing cells when compared with TcVps15-K219D-HA. Our results reveal for the first time a role of TcVps15 as a key regulator of TcVps34 enzymatic activity and implicate the TcVps15-Vps34 complex in autophagy in T. cruzi, exposing a new key pathway to explore novel chemotherapeutic targets. © 2016 The Author(s) Journal of Eukaryotic Microbiology © 2016 International Society of Protistologists.

  17. APOA5 -1131T>C and APOC3 -455T>C polymorphisms are associated with an increased risk of coronary heart disease.

    PubMed

    Sun, Y; Zhou, R B; Chen, D M

    2015-12-28

    The aim of this study was to investigate correlations between apolipoprotein A-V (APOA5) -1131T>C and apolipoprotein C-III (APOC3) -455T>C polymorphisms and coronary heart disease (CHD). PubMed, Ovid, Cochrane Library, Embase, China National Knowledge Infrastructure, and Wanfang databases were searched using combinations of keywords relating to these polymorphisms and CHD. Studies retrieved from database searches were screened using our stringent inclusion and exclusion criteria, and Comprehensive Meta-Analysis Version 2.0 software was used for statistical analyses. In total, 115 studies were initially retrieved and after further selection, 11 were included in the meta-analysis. These 11 articles comprised 4840 patients with CHD in the case group and 4913 healthy participants in the control group. Meta-analysis revealed that APOA5 -1131T>C and APOC3 -455T>C polymorphisms increased CHD risk. In addition, subgroup analysis by ethnicity showed that while the -1131T>C polymorphism elevated the risk of CHD in the Caucasian population under both allelic and dominant models, this increased risk was observed only under a dominant model in the Asian population. The results of our meta-analysis point to a strong link between both APOA5 -1131T>C and APOC3 -455T>C polymorphisms and an increased risk of CHD. Thus, these polymorphisms constitute important predictive indicators of CHD susceptibility.

  18. Evaluation of Weldability for MAG and LASER with Galvannealed Steel.

    PubMed

    Kim, Jong-Hee; Bang, Han-Sur; Bang, Hee-Seon

    2018-03-01

    Lower-arm, one of the components in automotive suspension module, has been fabricated by MAG welding in general which is lap jointed with 2 mm thick galvannealed steel sheet (SGAPH440). This welding process produces some problems such as significantly much spatters and weld defects of porosity in welded joint, which degrades productivity and weldability. Therefore, in order to solve these problems, this study has been tried to apply two types of solid wires with different chemical composition rate of Si and Mn, in MAG welding process. Moreover, the laser welding process has been adopted to fabricate the low-arm and compared with those of MAG welding, in terms of mechanical and metallurgical characteristics. It was observed that in MAG welded joints, much more spatters were occurred in using solid wire with higher Si and Mn contains. The maximum tensile-shear strength in laser welded joints was approximately 16.7 kN, which was almost equal to that of in MAG welded joints. The microstructure showed ferrite and martensite in weld metal in MAG and laser welded joints indicating no significantly grain size change.

  19. Development of a cryogenically cooled platform for the Magnetized Liner Inertial Fusion (MagLIF) Program [Development of a cryogenically-cooled platform for the Magnetized Liner Inertial Fusion (MagLIF) Concept

    DOE PAGES

    Awe, T. J.; Shelton, K. P.; Sefkow, A. B.; ...

    2017-09-25

    A cryogenically cooled hardware platform has been developed and commissioned on the Z Facility at Sandia National Laboratories in support of the Magnetized Liner Inertial Fusion (MagLIF) Program. MagLIF is a magneto-inertial fusion concept that employs a magnetically imploded metallic tube (liner) to compress and inertially confine premagnetized and preheated fusion fuel. The fuel is preheated using a ~2 kJ laser that must pass through a ~1.5-3.5-μm-thick polyimide “window” at the target’s laser entrance hole (LEH). As the terawatt-class laser interacts with the dense window, laser plasma instabilities (LPIs) can develop, which reduce the preheat energy delivered to the fuel,more » initiate fuel contamination, and degrade target performance. Cryogenically cooled targets increase the parameter space accessible to MagLIF target designs by allowing nearly 10 times thinner windows to be used for any accessible gas density. Thinner LEH windows reduce the deleterious effects of difficult to model LPIs. The Z Facility’s cryogenic infrastructure has been significantly altered to enable compatibility with the premagnetization and fuel preheat stages of MagLIF. The MagLIF cryostat brings the liquid helium coolant directly to the target via an electrically resistive conduit. This design maximizes cooling power while allowing rapid diffusion of the axial magnetic field supplied by external Helmholtz-like coils. A variety of techniques have been developed to mitigate the accumulation of ice from vacuum chamber contaminants on the cooled LEH window, as even a few hundred nanometers of ice would impact laser energy coupling to the fuel region. Here, the MagLIF cryostat has demonstrated compatibility with the premagnetization and preheat stages of MagLIF and the ability to cool targets to liquid deuterium temperatures in approximately 5 min.« less

  20. Development of a cryogenically cooled platform for the Magnetized Liner Inertial Fusion (MagLIF) Program [Development of a cryogenically-cooled platform for the Magnetized Liner Inertial Fusion (MagLIF) Concept

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Awe, T. J.; Shelton, K. P.; Sefkow, A. B.

    A cryogenically cooled hardware platform has been developed and commissioned on the Z Facility at Sandia National Laboratories in support of the Magnetized Liner Inertial Fusion (MagLIF) Program. MagLIF is a magneto-inertial fusion concept that employs a magnetically imploded metallic tube (liner) to compress and inertially confine premagnetized and preheated fusion fuel. The fuel is preheated using a ~2 kJ laser that must pass through a ~1.5-3.5-μm-thick polyimide “window” at the target’s laser entrance hole (LEH). As the terawatt-class laser interacts with the dense window, laser plasma instabilities (LPIs) can develop, which reduce the preheat energy delivered to the fuel,more » initiate fuel contamination, and degrade target performance. Cryogenically cooled targets increase the parameter space accessible to MagLIF target designs by allowing nearly 10 times thinner windows to be used for any accessible gas density. Thinner LEH windows reduce the deleterious effects of difficult to model LPIs. The Z Facility’s cryogenic infrastructure has been significantly altered to enable compatibility with the premagnetization and fuel preheat stages of MagLIF. The MagLIF cryostat brings the liquid helium coolant directly to the target via an electrically resistive conduit. This design maximizes cooling power while allowing rapid diffusion of the axial magnetic field supplied by external Helmholtz-like coils. A variety of techniques have been developed to mitigate the accumulation of ice from vacuum chamber contaminants on the cooled LEH window, as even a few hundred nanometers of ice would impact laser energy coupling to the fuel region. Here, the MagLIF cryostat has demonstrated compatibility with the premagnetization and preheat stages of MagLIF and the ability to cool targets to liquid deuterium temperatures in approximately 5 min.« less

  1. Analysis of accumulation of 99mTc-octreotide and 99mTc-EDDA/HYNIC-Tyr3-octreotide in the rat kidneys.

    PubMed

    Kopecky, Martin; Semecky, Vladimir; Trejtnar, Frantisek; Laznicek, Milan; Laznickova, Alice; Nachtigal, Petr; Decristoforo, Clemens; Mather, Stephen J; Mäcke, Helmut R

    2004-02-01

    The aim of this study was to compare renal handling and distribution of (99m)Tc-octreotide and (99m)Tc-EDDA/HYNIC-Tyr(3)-octreotide (HYNIC-TOC) in rats. In kidney perfusion experiments, the renal clearance value of (99m)Tc-octreotide was three times lower than that of (99m)Tc-EDDA/HYNIC-TOC. The predominant renal excretion of (99m)Tc-EDDA/HYNIC-TOC was associated with a high and long-term renal accumulation up to 48 hrs. Microautoradiographic results indicated that (99m)Tc-EDDA/HYNIC-TOC was retained mainly in the renal medulla within the cells of the collecting ducts and in the surrounding tissue. Lower positivity was found in the proximal and distal tubular cells. We conclude that the mechanism of renal accumulation of somatostatin analogues renal accumulation is complex and that proximal tubular reabsorption is probably not the main mechanism for uptake of (99m)Tc-EDDA/HYNIC-TOC in the kidneys. The presence of the somatostatin receptors, differences in the tonicity level within kidneys and other possible mechanisms could participate in their renal accumulation.

  2. (99m)Tc(CO)3(NTA): a (99m)Tc renal tracer with pharmacokinetic properties comparable to those of (131)I-OIH in healthy volunteers.

    PubMed

    Taylor, Andrew T; Lipowska, Malgorzata; Marzilli, Luigi G

    2010-03-01

    Studies in rats showed that the pharmacokinetics of the tricarbonyl core radiopharmaceutical (99m)Tc(CO)(3)-nitrilotriacetic acid, (99m)Tc(CO)(3)(NTA), were essentially identical to those of (131)I ortho-iodohippuran ((131)I-OIH), the clinical gold standard for the measurement of effective renal plasma flow. Our objective was to compare the pharmacokinetics of these 2 tracers in healthy volunteers. (99m)Tc(CO)(3)(NTA) was prepared with commercially available NTA and a commercially available kit and isolated by reversed-phase high-performance liquid chromatography. Approximately 74 MBq (2 mCi) of (99m)Tc(CO)(3)(NTA) were coinjected with 9.25 MBq (250 microCi) of (131)I-OIH in 9 volunteers, and simultaneous imaging of each tracer was performed for 24 min. Plasma clearances were determined from 8 blood samples obtained 3-90 min after injection using the single-injection, 2-compartment model. Plasma protein binding, red cell uptake, and percentage injected dose in the urine at 30 and 180 min were determined. There was no difference in the plasma clearances of (99m)Tc(CO)(3)(NTA) and (131)I-OIH, 475 +/- 105 mL/min versus 472 +/- 108 mL/min, respectively. The plasma protein binding and red cell uptake of (99m)Tc(CO)(3)(NTA) were 43% +/- 5% and 9% +/- 6%, respectively; both values were significantly lower (P < 0.001) than the plasma protein binding (75% +/- 3%) and red cell uptake (17% +/- 5%) of (131)I-OIH. There was no significant difference in the percentage injected dose recovered in the urine at 30 min and at 3 h; for comparison, the percentage dose in the urine at 3 h was 91% +/- 4% for (99m)Tc(CO)(3)(NTA) and 91% +/- 6% for (131)I-OIH (P = 0.96). Image quality with (99m)Tc(CO)(3)(NTA) was excellent, and the renogram parameters were similar to those of (131)I-OIH. Preliminary results in healthy volunteers suggest that the pharmacokinetic behavior of (99m)Tc(CO)(3)(NTA) is comparable to that of (131)I-OIH.

  3. Thermodynamic description of Tc(iv) solubility and carbonate complexation in alkaline NaHCO3-Na2CO3-NaCl systems.

    PubMed

    Baumann, A; Yalçıntaş, E; Gaona, X; Polly, R; Dardenne, K; Prüßmann, T; Rothe, J; Altmaier, M; Geckeis, H

    2018-03-28

    The solubility of 99 Tc(iv) was investigated in dilute to concentrated carbonate solutions (0.01 M ≤ C tot ≤ 1.0 M, with C tot = [HCO 3 - ] + [CO 3 2- ]) under systematic variation of ionic strength (I = 0.3-5.0 M NaHCO 3 -Na 2 CO 3 -NaCl-NaOH) and pH m (-log[H + ] = 8.5-14.5). Strongly reducing conditions (pe + pH m ≈ 2) were set with Sn(ii). Carbonate enhances the solubility of Tc(iv) in alkaline conditions by up to 3.5 log 10 -units compared to carbonate-free systems. Solvent extraction and XANES confirmed that Tc was kept as +IV during the timeframe of the experiments (≤ 650 days). Solid phase characterization performed by XAFS, XRD, SEM-EDS, chemical analysis and TG-DTA confirmed that TcO 2 ·0.6H 2 O(am) controls the solubility of Tc(iv) under the conditions investigated. Slope analysis of the solubility data in combination with solid/aqueous phase characterization and DFT calculations indicate the predominance of the species Tc(OH) 3 CO 3 - at pH m ≤ 11 and C tot ≥ 0.01 M, for which thermodynamic and activity models are derived. Solubility data obtained above pH m ≈ 11 indicates the formation of previously unreported Tc(iv)-carbonate species, possibly Tc(OH) 4 CO 3 2- , although the likely formation of additional complexes prevents deriving a thermodynamic model valid for this pH m -region. This work provides the most comprehensive thermodynamic dataset available for the system Tc 4+ -Na + -Cl - -OH - -HCO 3 - -CO 3 2- -H 2 O(l) valid under a range of conditions relevant for nuclear waste disposal.

  4. Neurophysiological and clinical responses to rituximab in patients with anti-MAG polyneuropathy.

    PubMed

    Zara, Gabriella; Zambello, Renato; Ermani, M

    2011-12-01

    Rituximab treatment has shown clinical improvement in anti-myelin associated glycoprotein (MAG) polyneuropathy. We analyzed scores of clinical scales and the most sensitive electrophysiological parameters before and after immunomodulating treatment with rituximab in a group of patients affected by anti-MAG demyelinating polyneuropathy. Clinical scores, the percentage of CD20 B-lymphocytes, anti-MAG antibody titers and electrophysiological data in 7 patients with anti-MAG polyneuropathy were analyzed. The patients were examined before a cycle with rituximab, 6, 12 and 24 months after the end of the treatment. Two patients were treated with rituximab additional cycles and re-evaluated 48 months after the first treatment. There were no evident correlation between anti-MAG serum antibody titers or clinical scales and electrodiagnostic data. Significant decrease in the proportion of CD20 B-lymphocytes was observed. Significant anti-MAG antibodies titers reduction was detected after re-treatment. At follow-up, pinprik sensation and two point discrimination presented a significant improvement compared with the score before treatment. In our patients, rituximab did not improve any electrophysiological data. No correlation with anti-MAG serum antibodies course was found. With rituximab only pin sensibility improved. Rituximab re-treatment significantly reduces anti-MAG serum antibodies titers but improves only small fibers sensibility. Copyright © 2011 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  5. 75 FR 76962 - Application To Export Electric Energy; MAG Energy Solutions, Inc.

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-10

    ... DEPARTMENT OF ENERGY [OE Docket No. EA-306-A] Application To Export Electric Energy; MAG Energy Solutions, Inc. AGENCY: Office of Electricity Delivery and Energy Reliability, DOE. ACTION: Notice of Application. SUMMARY: MAG Energy Solutions, Inc. (MAG E.S.) has applied to renew its authority to transmit...

  6. 99mTc-N4-[Tyr3]Octreotate Versus 99mTc-EDDA/HYNIC-[Tyr3]Octreotide: an intrapatient comparison of two novel Technetium-99m labeled tracers for somatostatin receptor scintigraphy.

    PubMed

    Gabriel, Michael; Decristoforo, Clemens; Maina, Theodosia; Nock, Berthold; vonGuggenberg, Elisabeth; Cordopatis, Paul; Moncayo, Roy

    2004-02-01

    Tetraamine-[Tyr3]octreotate (Demotate) is a somatostatin (SST) analogue that can be easily labeled with 99mTc at high specific activities and showed promising preclinical properties for SST receptor scintigraphy. This study reports on the first intra-patient comparison of 99mTc-Demotate and another 99mTc-labeled SST analogue, 99mTc-EDDA/HYNIC-TOC (HYNIC-TOC). Five patients with carcinoid tumors (n = 2) and endocrine pancreatic tumors (n = 3) were investigated with both radiopharmaceuticals. 99mTc-Demotate rapidly visualized somatostatin receptor positive tumors as early as 15 minutes post-injection (p.i.) with maximum tumor uptake and tumor/organ ratios already 1 hour p.i. Organs of predominant physiological uptake were the spleen and the kidneys with no intestinal excretion detectable up to 24 hours. 99mTc-Demotate exhibited faster pharmacokinetic properties compared to HYNIC-TOC. Tumor/organ ratios at equivalent time points were higher or comparable for 99mTc-Demotate in three patients with a matching scan result. Equivocal findings were observed in two patients, i.e. comparable uptake behavior in larger lesions with differences in smaller ones. 99mTc-Demotate is a promising agent for somatostatin receptor scintigraphy providing images of excellent quality as early as 1 hour after injection.

  7. Migration to Current Open Source Technologies by MagIC Enables a More Responsive Website, Quicker Development Times, and Increased Community Engagement

    NASA Astrophysics Data System (ADS)

    Jarboe, N.; Minnett, R.; Koppers, A.; Constable, C.; Tauxe, L.; Jonestrask, L.

    2017-12-01

    The Magnetics Information Consortium (MagIC) supports an online database for the paleo, geo, and rock magnetic communities ( https://earthref.org/MagIC ). Researchers can upload data into the archive and download data as selected with a sophisticated search system. MagIC has completed the transition from an Oracle backed, Perl based, server oriented website to an ElasticSearch backed, Meteor based thick client website technology stack. Using JavaScript on both the sever and the client enables increased code reuse and allows easy offloading many computational operations to the client for faster response. On-the-fly data validation, column header suggestion, and spreadsheet online editing are some new features available with the new system. The 3.0 data model, method codes, and vocabulary lists can be browsed via the MagIC website and more easily updated. Source code for MagIC is publicly available on GitHub ( https://github.com/earthref/MagIC ). The MagIC file format is natively compatible with the PmagPy ( https://github.com/PmagPy/PmagPy) paleomagnetic analysis software. MagIC files can now be downloaded from the database and viewed and interpreted in the PmagPy GUI based tool, pmag_gui. Changes or interpretations of the data can then be saved by pmag_gui in the MagIC 3.0 data format and easily uploaded to the MagIC database. The rate of new contributions to the database has been increasing with many labs contributing measurement level data for the first time in the last year. Over a dozen file format conversion scripts are available for translating non-MagIC measurement data files into the MagIC format for easy uploading. We will continue to work with more labs until the whole community has a manageable workflow for contributing their measurement level data. MagIC will continue to provide a global repository for archiving and retrieving paleomagnetic and rock magnetic data and, with the new system in place, be able to more quickly respond to the community

  8. SHMUTZ & PROTON-DIAMANT H + Irradiated/Written-Hyper/Super-conductivity(HC/SC) Precognizance/Early Experiments Connections: Wet-Graphite Room-Tc & Actualized MgB2 High-Tc: Connection to Mechanical Bulk-Moduli/Hardness: Diamond Hydrocarbon-Filaments, Disorder, Nano-Powders:C,Bi,TiB2,TiC

    NASA Astrophysics Data System (ADS)

    Wunderman, Irwin; Siegel, Edward Carl-Ludwig; Lewis, Thomas; Young, Frederic; Smith, Adolph; Dresschhoff-Zeller, Gieselle

    2013-03-01

    SHMUTZ: ``wet-graphite''Scheike-....[Adv.Mtls.(7/16/12)]hyper/super-SCHMUTZ-conductor(S!!!) = ``wet''(?)-``graphite''(?) = ``graphene''(?) = water(?) = hydrogen(?) =ultra-heavy proton-bands(???) = ...(???) claimed room/high-Tc/high-Jc superconductOR ``p''-``wave''/ BAND(!!!) superconductIVITY and actualized/ instantiated MgB2 high-Tc superconductors and their BCS- superconductivity: Tc Siegel[ICMAO(77);JMMM 7,190(78)] connection to SiegelJ.Nonxline-Sol.40,453(80)] disorder/amorphous-superconductivity in nano-powders mechanical bulk/shear(?)-moduli/hardness: proton-irradiated diamond, powders TiB2, TiC,{Siegel[Semis. & Insuls.5:39,47, 62 (79)])-...``VS''/concommitance with Siegel[Phys.Stat.Sol.(a)11,45(72)]-Dempsey [Phil.Mag. 8,86,285(63)]-Overhauser-(Little!!!)-Seitz-Smith-Zeller-Dreschoff-Antonoff-Young-...proton-``irradiated''/ implanted/ thermalized-in-(optimal: BOTH heat-capacity/heat-sink & insulator/maximal dielectric-constant) diamond: ``VS'' ``hambergite-borate-mineral transformable to Overhauser optimal-high-Tc-LiBD2 in Overhauser-(NW-periodic-table)-Land: CO2/CH4-ETERNAL-sequestration by-product: WATER!!!: physics lessons from

  9. MagPy: A Python toolbox for controlling Magstim transcranial magnetic stimulators.

    PubMed

    McNair, Nicolas A

    2017-01-30

    To date, transcranial magnetic stimulation (TMS) studies manipulating stimulation parameters have largely used blocked paradigms. However, altering these parameters on a trial-by-trial basis in Magstim stimulators is complicated by the need to send regular (1Hz) commands to the stimulator. Additionally, effecting such control interferes with the ability to send TMS pulses or simultaneously present stimuli with high-temporal precision. This manuscript presents the MagPy toolbox, a Python software package that provides full control over Magstim stimulators via the serial port. It is able to maintain this control with no impact on concurrent processing, such as stimulus delivery. In addition, a specially-designed "QuickFire" serial cable is specified that allows MagPy to trigger TMS pulses with very low-latency. In a series of experimental simulations, MagPy was able to maintain uninterrupted remote control over the connected Magstim stimulator across all testing sessions. In addition, having MagPy enabled had no effect on stimulus timing - all stimuli were presented for precisely the duration specified. Finally, using the QuickFire cable, MagPy was able to elicit TMS pulses with sub-millisecond latencies. The MagPy toolbox allows for experiments that require manipulating stimulation parameters from trial to trial. Furthermore, it can achieve this in contexts that require tight control over timing, such as those seeking to combine TMS with fMRI or EEG. Together, the MagPy toolbox and QuickFire serial cable provide an effective means for controlling Magstim stimulators during experiments while ensuring high-precision timing. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. MagLIF scaling on Z and future machines

    NASA Astrophysics Data System (ADS)

    Slutz, Stephen; Stygar, William; Gomez, Matthew; Campbell, Edward; Peterson, Kyle; Sefkow, Adam; Sinars, Daniel; Vesey, Roger

    2015-11-01

    The MagLIF (Magnetized Liner Inertial Fusion) concept [S.A. Slutz et al Phys. Plasmas 17, 056303, 2010] has demonstrated [M.R. Gomez et al., PRL 113, 155003, 2014] fusion-relevant plasma conditions on the Z machine. We present 2D numerical simulations of the scaling of MagLIF on Z indicating that deuterium/tritium (DT) fusion yields greater than 100 kJ could be possible on Z when operated at a peak current of 25 MA. Much higher yields are predicted for MagLIF driven with larger peak currents. Two high performance pulsed-power machines (Z300 and Z800) have been designed based on Linear Transformer Driver (LTD) technology. The Z300 design would provide approximately 48 MA to a MagLIF load, while Z800 would provide about 66 MA. We used a parameterized Thevenin equivalent circuit to drive a series of 1D and 2D numerical simulations with currents between and beyond these two designs. Our simulations indicate that 5-10 MJ yields may be possible with Z300, while yields of about 1 GJ may be possible with Z800. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  11. Illuminating the Depths of the MagIC (Magnetics Information Consortium) Database

    NASA Astrophysics Data System (ADS)

    Koppers, A. A. P.; Minnett, R.; Jarboe, N.; Jonestrask, L.; Tauxe, L.; Constable, C.

    2015-12-01

    The Magnetics Information Consortium (http://earthref.org/MagIC/) is a grass-roots cyberinfrastructure effort envisioned by the paleo-, geo-, and rock magnetic scientific community. Its mission is to archive their wealth of peer-reviewed raw data and interpretations from magnetics studies on natural and synthetic samples. Many of these valuable data are legacy datasets that were never published in their entirety, some resided in other databases that are no longer maintained, and others were never digitized from the field notebooks and lab work. Due to the volume of data collected, most studies, modern and legacy, only publish the interpreted results and, occasionally, a subset of the raw data. MagIC is making an extraordinary effort to archive these data in a single data model, including the raw instrument measurements if possible. This facilitates the reproducibility of the interpretations, the re-interpretation of the raw data as the community introduces new techniques, and the compilation of heterogeneous datasets that are otherwise distributed across multiple formats and physical locations. MagIC has developed tools to assist the scientific community in many stages of their workflow. Contributors easily share studies (in a private mode if so desired) in the MagIC Database with colleagues and reviewers prior to publication, publish the data online after the study is peer reviewed, and visualize their data in the context of the rest of the contributions to the MagIC Database. From organizing their data in the MagIC Data Model with an online editable spreadsheet, to validating the integrity of the dataset with automated plots and statistics, MagIC is continually lowering the barriers to transforming dark data into transparent and reproducible datasets. Additionally, this web application generalizes to other databases in MagIC's umbrella website (EarthRef.org) so that the Geochemical Earth Reference Model (http://earthref.org/GERM/) portal, Seamount Biogeosciences

  12. Disposable MagLev centrifugal blood pump utilizing a cone-shaped impeller.

    PubMed

    Hijikata, Wataru; Sobajima, Hideo; Shinshi, Tadahiko; Nagamine, Yasuyuki; Wada, Suguru; Takatani, Setsuo; Shimokohbe, Akira

    2010-08-01

    To enhance the durability and reduce the blood trauma of a conventional blood pump with a cone-shaped impeller, a magnetically levitated (MagLev) technology has been applied to the BioPump BPX-80 (Medtronic Biomedicus, Inc., Minneapolis, MN, USA), whose impeller is supported by a mechanical bearing. The MagLev BioPump (MagLev BP), which we have developed, has a cone-shaped impeller, the same as that used in the BPX-80. The suspension and driving system, which is comprised of two degrees of freedom, radial-controlled magnetic bearing, and a simply structured magnetic coupling, eliminates any physical contact between the impeller and the housing. To reduce both oscillation of the impeller and current in the coils, the magnetic bearing system utilizes repetitive and zero-power compensators. In this article, we present the design of the MagLev mechanism, measure the levitational accuracy of the impeller and pressure-flow curves (head-quantity [HQ] characteristics), and describe in vitro experiments designed to measure hemolysis. For the flow-induced hemolysis of the initial design to be reduced, the blood damage index was estimated by using computational fluid dynamics (CFD) analysis. Stable rotation of the impeller in a prototype MagLev BP from 0 to 2750 rpm was obtained, yielding a flow rate of 5 L/min against a head pressure in excess of 250 mm Hg. Because the impeller of the prototype MagLev BP is levitated without contact, the normalized index of hemolysis was 10% less than the equivalent value with the BPX-80. The results of the CFD analysis showed that the shape of the outlet and the width of the fluid clearances have a large effect on blood damage. The prototype MagLev BP satisfied the required HQ characteristics (5 L/min, 250 mm Hg) for extracorporeal circulation support with stable levitation of the impeller and showed an acceptable level of hemolysis. The simulation results of the CFD analysis indicated the possibility of further reducing the blood damage of

  13. MagR Alone Is Insufficient to Confer Cellular Calcium Responses to Magnetic Stimulation

    PubMed Central

    Pang, Keliang; You, He; Chen, Yanbo; Chu, Pengcheng; Hu, Meiqin; Shen, Jianying; Guo, Wei; Xie, Can; Lu, Bai

    2017-01-01

    Magnetic manipulation of cell activity offers advantages over optical manipulation but an ideal tool remains elusive. The MagR protein was found through its interaction with cryptochrome (Cry) and the protein in solution appeared to respond to magnetic stimulation (MS). After we initiated an investigation on the specific role of MagR in cellular response to MS, a subsequent study claimed that MagR expression alone could achieve cellular activation by MS. Here we report that despite systematically testing different ways of measuring intracellular calcium and different MS protocols, it was not possible to detect any cellular or neuronal responses to MS in MagR-expressing HEK cells or primary neurons from the dorsal root ganglion and the hippocampus. By contrast, in neurons co-expressing MagR and channelrhodopin, optical but not MS increased calcium influx in hippocampal neurons. Our results indicate that MagR alone is not sufficient to confer cellular magnetic responses. PMID:28360843

  14. Neurologic syndrome associated with homozygous mutation at MAG sialic acid binding site.

    PubMed

    Roda, Ricardo H; FitzGibbon, Edmond J; Boucekkine, Houda; Schindler, Alice B; Blackstone, Craig

    2016-08-01

    The MAG gene encodes myelin-associated glycoprotein (MAG), an abundant protein involved in axon-glial interactions and myelination during nerve regeneration. Several members of a consanguineous family with a clinical syndrome reminiscent of Pelizaeus-Merzbacher disease and demyelinating leukodystrophy on brain MRI were recently found to harbor a homozygous missense p.Ser133Arg MAG mutation. Here, we report two brothers from a nonconsanguineous family afflicted with progressive cognitive impairment, neuropathy, ataxia, nystagmus, and gait disorder. Exome sequencing revealed the homozygous missense mutation p.Arg118His in MAG. This Arg118 residue in immunoglobulin domain 1 is critical for sialic acid binding, providing a compelling mechanistic basis for disease pathogenesis.

  15. Early detection of rheumatoid arthritis in rats and humans with 99mTc-3PRGD2 scintigraphy: imaging synovial neoangiogenesis.

    PubMed

    Wu, Yu; Zhang, Guojian; Wang, Xiangcheng; Zhao, Zhenfang; Wang, Tao; Wang, Xuemei; Li, Xiao-Feng

    2017-01-24

    To validate 99mTc-labeled arginylglycylaspartic acid (99mTc-3PRGD2) scintigraphy as a means to image synovial neoangiogenesis in joints afflicted by rheumatoid arthritis and to investigate its potential in the early detection and management of rheumatoid arthritis. Rheumatoid arthritis and osteoarthritis were generated in Sprague Dawley rats by type II collagen immunization and papain injection, respectively. Rats were imaged with 99mTc-3PRGD2 and 99mTc- methyl diphosphonate (99mTc MDP). X-ray images were also obtained and assessed by a radiologist. Immunohistochemistry of αvβ3 and CD31confirmed the onset of synovial neoangiogenesis. The effect of bevacizumab on rheumatoid arthritis was followed with 99mTc-3PRGD2 scintigraphy. A patient with rheumatoid arthritis and a healthy volunteer were scanned with 99mTc-3PRGD2. Two weeks after immunization, a significant increase in 99mTc-3PRGD2 was observed in the joints of the rheumatoid arthritis model though uptake in osteoarthritis model and untreated controls was low. 99mTc-MDP whole body scans failed to distinguish early rheumatoid arthritis joints from healthy controls. The expression of αvβ3 and CD31was significantly higher in the joints of rheumatoid arthritis rats compared to normal controls. In serial 99mTc-3PRGD2 scintigraphy studies, 99mTc-3PRGD2 uptake increased in parallel with disease progression. Bevacizumab anti-angiogenetic therapy both improved the symptoms of the rheumatoid arthritis rats and significantly decreased 99mTc-3PRGD2 uptake. Significantly higher 99mTc-3PRGD2 accumulation was also observed in rheumatoid arthritis joints in the patient. Our findings indicate that 99mTc-3PRGD2 scintigraphy could detect early rheumatoid arthritis by imaging the associated synovial neoangiogenesis, and may be useful in disease management.

  16. MagCloud: magazine self-publishing for the long tail

    NASA Astrophysics Data System (ADS)

    Koh, Kok-Wei; Chatow, Ehud

    2010-02-01

    In June of 2008, Hewlett-Packard Labs launched MagCloud, a print-on-demand web service for magazine selfpublishing. MagCloud enables anyone to publish their own magazine by simply uploading a PDF file to the site. There are no setup fees, minimum print runs, storage requirements or waste due to unsold magazines. Magazines are only printed when an order is placed, and are shipped directly to the end customer. In the course of building this web service, a number of technological challenges were encountered. In this paper, we will discuss these challenges and the methods used to overcome them. Perhaps the most important decision in enabling the successful launch of MagCloud was the choice to offer a single product. This simplified the PDF validation phase and streamlined the print fulfillment process such that orders can be printed, folded and trimmed in batches, rather than one-by-one. In a sense, MagCloud adopted the Ford Model T approach to manufacturing, where having just a single model with little or no options allows for efficiencies in the production line, enabling a lower product price and opening the market to a much larger customer base. This platform has resulted in a number of new niche publications - the long tail of publishing.

  17. THOR Fluxgate Magnetometer (MAG)

    NASA Astrophysics Data System (ADS)

    Nakamura, Rumi; Eastwood, Jonathan; Magnes, Werner; Valavanoglou, Aris; Carr, Christopher M.; O'Brien, Helen L.; Narita, Yasuhito; Delva, Magda; Chen, Christopher H. K.; Plaschke, Ferdinand; Soucek, Jan

    2016-04-01

    Turbulence Heating ObserveR (THOR) is the first mission ever flown in space dedicated to plasma turbulence. The goal of the Fluxgate Magnetometer (MAG) is to measure the DC to low frequency ambient magnetic field. The design of the magnetometer consists of two tri-axial sensors and the related magnetometer electronics; the electronics are hosted on printed circuit boards in the common electronics box of the fields and wave processor (FWP). A fully redundant two sensor system mounted on a common boom and the new miniaturized low noise design based on MMS and Solar Orbiter instruments enable accurate measurement throughout the region of interest for THOR science. The usage of the common electronics hosted by FWP guarantees to fulfill the required timing accuracy with other fields measurements. These improvements are important to obtain precise measurements of magnetic field, which is essential to estimate basic plasma parameters and correctly identify the spatial and temporal scales of the turbulence. Furthermore, THOR MAG provides high quality data with sufficient overlap with the Search Coil Magnetometer (SCM) in frequency space to obtain full coverage of the wave forms over all the frequencies necessary to obtain the full solar wind turbulence spectrum from MHD to kinetic range with sufficient accuracy.

  18. Nanoparticulas basadas en complejos de Fe(II) con transicion de espin: sintesis, caracterizacion y aplicaciones en electronica molecular

    NASA Astrophysics Data System (ADS)

    Monrabal Capilla, Maria

    Esta tesis doctoral esta organizada en 5 capitulos y esta destinada al estudio de sistemas de Fe (II) que presentan el fenomeno de la transicion de espin a escala nanometrica. El capitulo 1 contiene una introduccion general sobre materiales moleculares multifuncionales, destacando aquellos ejemplos mas importantes. Por otro lado, se explicara el fenomeno de la transicion de espin, tratando aspectos conceptuales, los antecedentes mas importantes y la situacion actual. En el capitulo 2 se describen los diferentes procesos existentes para la obtencion de diferentes tipos de nanoparticulas. Ademas, se presenta la sintesis y caracterizacion de nanoparticulas del polimero de coordinacion unidimensional [Fe(Htrz)2(trz)]BF4, obtenidas mediante el metodo de micelas inversas. Estas nanoparticulas, con una estrecha distribucion de tamanos centrada alrededor de los 11 nm, presentan una transicion de espin muy abrupta, con un ancho ciclo de histeresis termica de unos 40K. En el capitulo 3 se describe el proceso de modificacion del tamano de las nanoparticulas descritas en el capitulo anterior, llevado a cabo variando la proporcion de surfactante/H2O en el medio. Ademas, con el objetivo de modificar las propiedades magneticas de las nanoparticulas obtenidas en el capitulo 2, se lleva a cabo la sintesis de nanoparticulas de polimeros de la misma familia del [Fe(Htrz)2(trz)]BF4. En concreto se sintetizaron 3 nuevos tipos de nanoparticulas basadas en el polimero [Fe(Htrz)1-x(NH2trz)x](ClO4)2, siendo x = 0.05, 0.15 y 0.3, en cada caso. Estas nanoparticulas siguen presentando una estrecha distribucion de tamanos y una transicion de espin muy abrupta y con un ancho ciclo de histeresis. Ademas, se observa que este ciclo se desplaza a temperaturas mas proximas a la temperatura ambiente a medida que se aumenta el porcentaje de 4-amino-1, 2, 4- triazol en la muestra. Pero al mismo tiempo se produce una disminucion de la anchura de este ciclo. Por ultimo, en este capitulo se presenta la

  19. IgM MGUS associated with anti-MAG neuropathy: a single institution experience.

    PubMed

    Talamo, Giampaolo; Mir, Muhammad A; Pandey, Manoj K; Sivik, Jeffrey K; Raheja, Divisha

    2015-06-01

    Anti-MAG neuropathy is a very rare form of acquired polyneuropathy associated with IgM monoclonal gammopathy of undetermined significance (MGUS). We conducted a retrospective review of 194 consecutive MGUS patients seen at the Penn State Hershey Cancer Institute. We identified six patients among 37 (16 %) with IgM MGUS with anti-MAG neuropathy. Interestingly, an additional patient had anti-MAG neuropathy without MGUS. Common clinical manifestations were numbness and paresthesias of the extremities and gait imbalance. All four patients treated with rituximab and none of the three untreated ones had a subjective improvement of their symptoms. We conclude that all patients with IgM MGUS and neuropathy should be screened for anti-MAG antibodies and, if positive, they should be offered treatment with rituximab.

  20. Fuel magnetization without external field coils (AutoMag)

    NASA Astrophysics Data System (ADS)

    Slutz, Stephen; Jennings, Christopher; Awe, Thomas; Shipley, Gabe; Lamppa, Derek; McBride, Ryan

    2016-10-01

    Magnetized Liner Inertial Fusion (MagLIF) has produced fusion-relevant plasma conditions on the Z accelerator where the fuel was magnetized using external field coils. We present a novel concept that does not need external field coils. This concept (AutoMag) magnetizes the fuel during the early part of the drive current by using a composite liner with helical conduction paths separated by insulating material. The drive is designed so the current rises slowly enough to avoid electrical breakdown of the insulators until a sufficiently strong magnetic field is established. Then the current rises more quickly, which causes the insulators to break down allowing the drive current to follow an axial path and implode the liner. Low inductance magnetically insulated power feeds can be used with AutoMag to increase the drive current without interfering with diagnostic access. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  1. Laparoendoscopic single site (LESS) in vivo suturing using a magnetic anchoring and guidance system (MAGS) camera in a porcine model: impact on ergonomics and workload.

    PubMed

    Yin, Gang; Han, Woong Kyu; Faddegon, Stephen; Tan, Yung Khan; Liu, Zhuo-Wei; Olweny, Ephrem O; Scott, Daniel J; Cadeddu, Jeffrey A

    2013-01-01

    To compare the ergonomics and workload of the surgeon during single-site suturing while using the magnetic anchoring and guidance system (MAGS) camera vs a conventional laparoscope. Seven urologic surgeons were enrolled and divided into an expert group (n=2) and a novice group (n=5) according to their laparoendoscopic single-site (LESS) experience. Each surgeon performed 2 conventional LESS and 2 MAGS camera-assisted LESS vesicostomy closures in a porcine model. A Likert scale (scoring 1-5) questionnaire assessing workload, ergonomics, technical difficulty, visualization, and needle handling, as well as a validated National Aeronautics and Space Administration Task Load Index (NASA-TLX) questionnaire were used to evaluate the tasks and workloads. MAGS LESS suturing was universally favored by expert and novice surgeons compared with conventional LESS in workload (3.4 vs 4.2), ergonomics (3.4 vs 4.4), technical challenge (3.3 vs 4.3), visualization (2.4 vs 3.3), and needle handling (3.1 vs 3.9 respectively; P<.05 for all categories). Surgeon NASA-TLX assessments found MAGS LESS suturing significantly decreased the workload in physical demand (P=.004), temporal demand (P=.017), and effort (P=.006). External instrument clashing was significantly reduced in MAGS LESS suturing (P<.001). The total operative time of MAGS LESS suturing was comparable to that of conventional LESS (P=.89). MAGS camera technology significantly decreased surgeon workload and improved ergonomics. Nevertheless, LESS suturing and knot tying remains a challenging task that requires training, regardless of which camera is used. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Early detection of rheumatoid arthritis in rats and humans with 99mTc-3PRGD2 scintigraphy: imaging synovial neoangiogenesis

    PubMed Central

    Wang, Xiangcheng; Zhao, Zhenfang; Wang, Tao; Wang, Xuemei; Li, Xiao-Feng

    2017-01-01

    Objectives: To validate 99mTc-labeled arginylglycylaspartic acid (99mTc-3PRGD2) scintigraphy as a means to image synovial neoangiogenesis in joints afflicted by rheumatoid arthritis and to investigate its potential in the early detection and management of rheumatoid arthritis. Methods: Rheumatoid arthritis and osteoarthritis were generated in Sprague Dawley rats by type II collagen immunization and papain injection, respectively. Rats were imaged with 99mTc-3PRGD2 and 99mTc- methyl diphosphonate (99mTc MDP). X-ray images were also obtained and assessed by a radiologist. Immunohistochemistry of αvβ3 and CD31confirmed the onset of synovial neoangiogenesis. The effect of bevacizumab on rheumatoid arthritis was followed with 99mTc-3PRGD2 scintigraphy. A patient with rheumatoid arthritis and a healthy volunteer were scanned with 99mTc-3PRGD2. Results: Two weeks after immunization, a significant increase in 99mTc-3PRGD2 was observed in the joints of the rheumatoid arthritis model though uptake in osteoarthritis model and untreated controls was low. 99mTc-MDP whole body scans failed to distinguish early rheumatoid arthritis joints from healthy controls. The expression of αvβ3 and CD31was significantly higher in the joints of rheumatoid arthritis rats compared to normal controls. In serial 99mTc-3PRGD2 scintigraphy studies, 99mTc-3PRGD2 uptake increased in parallel with disease progression. Bevacizumab anti-angiogenetic therapy both improved the symptoms of the rheumatoid arthritis rats and significantly decreased 99mTc-3PRGD2 uptake. Significantly higher 99mTc-3PRGD2 accumulation was also observed in rheumatoid arthritis joints in the patient. Conclusions: Our findings indicate that 99mTc-3PRGD2 scintigraphy could detect early rheumatoid arthritis by imaging the associated synovial neoangiogenesis, and may be useful in disease management. PMID:27992368

  3. Global and local magnetic mapping using CrowdMag data

    NASA Astrophysics Data System (ADS)

    Saltus, R.; Nair, M. C.

    2016-12-01

    NOAA's National Centers for Environmental Information (NCEI), in partnership with the University of Colorado's CIRES develop magnetic field models to aid navigation, resource exploration and scientific research. We use observatories, satellites and ship/airborne surveys to map and model the Earth's magnetic field. However, the available measurements leave gaps in coverage, particularly for short-wavelength anomalies associated with man-made infrastructure ("urban noise"). In 2014, we started a project to address these gaps through the collection of vector magnetic data from digital magnetometers in smartphones. In October 2014, we released the "CrowdMag" Android and iOS apps for harvesting data from phones. Currently, the CrowdMag project has more than 10,000 enthusiastic users contributing more than 12 million magnetic data measurements from around the world. We present the first analysis results from the crowdsourced magnetic data. A global magnetic model derived solely from CrowdMag data is consistent to degree and order 4 with satellite-derived models such as World Magnetic Model. A unique contribution of CrowdMag project is the collection of ground level magnetic data in densely populated regions with an unprecedented spatial resolution. To demonstrate, we generated a magnetic map (by binning the data collected in 200x200m cells) of central Boulder, Colorado using 170,000 data points collected by about 60 devices over the duration October 2014- January 2016. The median value is consistent with the expected magnitude of the Earth's background magnetic field. The standard deviation of the CrowdMag total field (F) values is much higher than the expected natural (i.e., diurnal and geologic) magnetic field variation. However, the phone's magnetometer is sensitive enough to capture the larger magnitude magnetic signature from the urban magnetic sources. We discuss the potential reliability of crowdsourced magnetic maps and their applications to navigation and other

  4. "Lights on at the end of the party": are lads' mags mainstreaming dangerous sexism?

    PubMed

    Horvath, Miranda A H; Hegarty, Peter; Tyler, Suzannah; Mansfield, Sophie

    2012-11-01

    Research has suggested that some magazines targeted at young men - lads' mags - are normalizing extreme sexist views by presenting those views in a mainstream context. Consistent with this view, young men in Study 1 (n = 90) identified more with derogatory quotes about women drawn from recent lads' mags, and from interviews with convicted rapists, when those quotes were attributed to lads' mags, than when they were attributed to convicted rapists. In Study 2, 40 young women and men could not reliably judge the source of those same quotes. While these participants sometimes voiced the belief that the content of lads' mags was 'normal' while rapists' talk was 'extreme', they categorized quotes from both sources as derogatory with equal frequency. Jointly, the two studies show an overlap in the content of convicted rapists' talk and the contents of contemporary lads' mags, and suggest that the framing of such content within lads' mags may normalize it for young men. ©2011 The British Psychological Society.

  5. Toward organometallic (99m)Tc imaging agents: synthesis of water-stable (99)Tc-NHC complexes.

    PubMed

    Benz, Michael; Spingler, Bernhard; Alberto, Roger; Braband, Henrik

    2013-11-20

    (99)Tc(V)O2-NHC complexes containing monodentate and bidentate N-heterocyclic carbenes (NHCs) have been prepared by the reactions of [TcO(glyc)2](-) (glyc = ethyleneglycolato) with 1,3-dimethylimidazoline-2-ylidene (L1), 1,1'-methylene-3,3'-dimethyl-4,4'-diimidazoline-2,2'-diylidene (L2), and 1,1'-methylene-3,3'-diethyl-4,4'-diimidazoline-2,2'-diylidene (L3) in THF. The resulting complexes were fully characterized and their stabilities investigated. While complexes with monodentate NHCs only are hydrolytically unstable, complexes containing bidentate NHCs are water-stable over a broad pH range. The high water stability allows interconversion of the {(99)Tc(V)O2}(+) core into {(99)Tc(V)OCl}(2+) with HCl as the H(+) and Cl(-) source. An alternative procedure to obtain (99)Tc(V)O2-NHC complexes is the in situ deprotonation of imidazolium salts, enabling the preparation of (99)Tc(V)O2-NHC compounds without free NHCs, thus increasing the scope of NHC ligands drastically. The remarkable stability and pH-controllable reactivity of the new complexes underlines the potential of NHCs as stabilizing ligands for (99)Tc complexes and paves the way for the first (99m)Tc-NHC complexes in the future.

  6. Mycoplasma agalactiae MAG_5040 is a Mg2+-Dependent, Sugar-Nonspecific SNase Recognised by the Host Humoral Response during Natural Infection

    PubMed Central

    Cacciotto, Carla; Addis, Maria Filippa; Coradduzza, Elisabetta; Carcangiu, Laura; Nuvoli, Anna Maria; Tore, Gessica; Dore, Gian Mario; Pagnozzi, Daniela; Uzzau, Sergio; Chessa, Bernardo; Pittau, Marco; Alberti, Alberto

    2013-01-01

    In this study the enzymatic activity of Mycoplasma agalactiae MAG_5040, a magnesium-dependent nuclease homologue to the staphylococcal SNase was characterized and its antigenicity during natural infections was established. A UGA corrected version of MAG_5040, lacking the region encoding the signal peptide, was expressed in Escherichia coli as a GST fusion protein. Recombinant GST-MAG_5040 exhibits nuclease activity similar to typical sugar-nonspecific endo- and exonucleases, with DNA as the preferred substrate and optimal activity in the presence of 20 mM MgCl2 at temperatures ranging from 37 to 45°C. According to in silico analyses, the position of the gene encoding MAG_5040 is consistently located upstream an ABC transporter, in most sequenced mycoplasmas belonging to the Mycoplasma hominis group. In M. agalactiae, MAG_5040 is transcribed in a polycistronic RNA together with the ABC transporter components and with MAG_5030, which is predicted to be a sugar solute binding protein by 3D modeling and homology search. In a natural model of sheep and goats infection, anti-MAG_5040 antibodies were detected up to 9 months post infection. Taking into account its enzymatic activity, MAG_5040 could play a key role in Mycoplasma agalactiae survival into the host, contributing to host pathogenicity. The identification of MAG_5040 opens new perspectives for the development of suitable tools for the control of contagious agalactia in small ruminants. PMID:23469065

  7. Is distal motor and/or sensory demyelination a distinctive feature of anti-MAG neuropathy?

    PubMed

    Lozeron, Pierre; Ribrag, Vincent; Adams, David; Brisset, Marion; Vignon, Marguerite; Baron, Marine; Malphettes, Marion; Theaudin, Marie; Arnulf, Bertrand; Kubis, Nathalie

    2016-09-01

    To report the frequency of the different patterns of sensory and motor electrophysiological demyelination distribution in patients with anti-MAG neuropathy in comparison with patients with IgM neuropathy without MAG reactivity (IgM-NP). Thirty-five anti-MAG patients at early disease stage (20.1 months) were compared to 23 patients with IgM-NP; 21 CIDP patients and 13 patients with CMT1a neuropathy were used as gold standard neuropathies with multifocal and homogeneous demyelination, respectively. In all groups, standard motor and sensory electrophysiological parameters, terminal latency index and modified F ratio were investigated. Motor electrophysiological demyelination was divided in four profiles: distal, homogeneous, proximal, and proximo-distal. Distal sensory and sensorimotor demyelination were evaluated. Anti-MAG neuropathy is a demyelinating neuropathy in 91 % of cases. In the upper limbs, reduced TLI is more frequent in anti-MAG neuropathy, compared to IgM-NP. But, predominant distal demyelination of the median nerve is encountered in only 43 % of anti-MAG neuropathy and is also common in IgM-NP (35 %). Homogeneous demyelination was the second most frequent pattern (31 %). Concordance of electrophysiological profiles across motor nerves trunks is low and median nerve is the main site of distal motor conduction slowing. Reduced sensory conduction velocities occurs in 14 % of patients without evidence of predominant distal slowing. Simultaneous sensory and motor distal slowing was more common in the median nerve of anti-MAG neuropathy than IgM-NP. Electrophysiological distal motor demyelination and sensory demyelination are not a distinctive feature of anti-MAG reactivity. In anti-MAG neuropathy it is mainly found in the median nerve suggesting a frequent nerve compression at wrist.

  8. Magnetically separable polymer (Mag-MIP) for selective analysis of biotin in food samples.

    PubMed

    Uzuriaga-Sánchez, Rosario Josefina; Khan, Sabir; Wong, Ademar; Picasso, Gino; Pividori, Maria Isabel; Sotomayor, Maria Del Pilar Taboada

    2016-01-01

    This work presents an efficient method for the preparation of magnetic nanoparticles modified with molecularly imprinted polymers (Mag-MIP) through core-shell method for the determination of biotin in milk food samples. The functional monomer acrylic acid was selected from molecular modeling, EGDMA was used as cross-linking monomer and AIBN as radical initiator. The Mag-MIP and Mag-NIP were characterized by FTIR, magnetic hysteresis, XRD, SEM and N2-sorption measurements. The capacity of Mag-MIP for biotin adsorption, its kinetics and selectivity were studied in detail. The adsorption data was well described by Freundlich isotherm model with adsorption equilibrium constant (KF) of 1.46 mL g(-1). The selectivity experiments revealed that prepared Mag-MIP had higher selectivity toward biotin compared to other molecules with different chemical structure. The material was successfully applied for the determination of biotin in diverse milk samples using HPLC for quantification of the analyte, obtaining the mean value of 87.4% recovery. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Solar Probe Plus MAG Sensor Thermal Design for Low Heater Power and Extreme Thermal Environment

    NASA Technical Reports Server (NTRS)

    Choi, Michael K.

    2015-01-01

    The heater power available for the Solar Probe Plus FIELDS MAG sensor is less than half of the heritage value for other missions. Nominally the MAG sensors are in the spacecraft's umbra. In the worst hot case, approximately 200 spacecraft communication downlinks, up to 10 hours each, are required at 0.7 AU. These downlinks require the spacecraft to slew 45 deg. about the Y-axis, exposing the MAG sensors and boom to sunlight. This paper presents the thermal design to meet the MAG sensor thermal requirements in the extreme thermal environment and with low heater power. A thermal balance test on the MAG sensor engineering model has verified the thermal design and correlated the thermal model for flight temperature predictions.

  10. NK cells and their receptors in naive and rituximab-treated patients with anti-MAG polyneuropathy.

    PubMed

    Benedetti, Luana; Facco, Monica; Franciotta, Diego; Dalla Torre, Chiara; Campagnolo, Marta; Lucchetta, Marta; Boscaro, Elisa; Ermani, Mario; Del Sette, Massimo; Berno, Tamara; Candiotto, Laura; Zambello, Renato; Briani, Chiara

    2013-08-15

    Natural killer (NK) cells can bridge innate and acquired immunity, and play a role in autoimmunity. A few studies evaluated the distribution of NK cells and the expression of their receptors in chronic immune-mediated demyelinating polyneuropathies. We investigated NK cell distribution and NK cell receptor expression in 20 naïve patients with anti-MAG polyneuropathy (MAG-PN). Using flow cytometry, we analysed NK cells and a series of NK cell receptors in the peripheral blood of patients with MAG-PN, and, as controls, in patients with chronic inflammatory demyelinating peripheral polyradiculoneuropathy (CIDP) and in healthy subjects. Six MAG-PN patients were also tested after rituximab treatment. At baseline the percentage of NK cells did not differ among the groups. KIR2DL2 receptor expression in MAG-PN patients was higher, andCD94/NKG2A receptor expression in both MAG-PN and CIDP patients was lower than in healthy controls. These abnormalities did not correlate with any clinical or demographic variable. No modification was found after rituximab therapy. The data suggest that MAG-PN shows abnormalities in NK cell receptors that characterise other autoimmune diseases, and cannot help in differential diagnosis with CIDP. The impairment of the relevant CD94/NKG2A inhibitory pathway, which might play a central role in the development and perpetuation of MAG-PN, warrants further functional investigations. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Exploring the Potential of (99m)Tc(CO)3-Labeled Triazolyl Peptides for Tumor Diagnosis.

    PubMed

    Gaonkar, Raghuvir H; Ganguly, Soumya; Baishya, Rinku; Dewanjee, Saikat; Sinha, Samarendu; Gupta, Amit; Ganguly, Shantanu; Debnath, Mita C

    2016-04-01

    In recent years the authors have reported on (99m)Tc(CO)3-labeled peptides that serve as carriers for biomolecules or radiopharmaceuticals to the tumors. In continuation of that work they report the synthesis of a pentapeptide (Met-Phe-Phe-Gly-His; pep-1), a hexapeptide (Met-Phe-Phe-Asp-Gly-His; pep-2), and a tetrapeptide (Asp-Gly-Arg-His; pep-3) and the attachment of 3-amino-1,2,4-triazole to the β carboxylic function of the aspartic acid unit of pep-2 and pep-3. The pharmacophores were radiolabeled in high yields with [(99m)Tc(CO)3(H2O)3](+) metal aqua ion, characterized for their stability in serum and saline, as well as in His solution, and found to be substantially stable. B16F10 cell line binding studies showed favorable uptake and internalization. In vivo behavior of the radiolabeled triazolyl peptides was assessed in mice bearing induced tumor. The (99m)Tc(CO)3-triazolyl pep-3 demonstrated rapid urinary clearance and comparatively better tumor uptake. Imaging studies showed visualization of the tumor using (99m)Tc(CO)3-triazolyl pep-3, but due to high abdominal background, low delineation occurred. Based on the results further experiments will be carried out for targeting tumor with triazolyl peptides.

  12. Beyond 31 mag arcsec-2: The Frontier of Low Surface Brightness Imaging with the Largest Optical Telescopes

    NASA Astrophysics Data System (ADS)

    Trujillo, Ignacio; Fliri, Jüergen

    2016-06-01

    The detection of structures in the sky with optical surface brightnesses fainter than 30 mag arcsec-2 (3σ in 10 × 10 arcsec boxes; r-band) has remained elusive in current photometric deep surveys. Here we show how present-day telescopes of 10 m class can provide broadband imaging 1.5-2 mag deeper than most previous results within a reasonable amount of time (I.e., <10 hr on-source integration). In particular, we illustrate the ability of the 10.4 m Gran Telescopio de Canarias telescope to produce imaging with a limiting surface brightness of 31.5 mag arcsec-2 (3σ in 10 × 10 arcsec boxes; r-band) using 8.1 hr on source. We apply this power to explore the stellar halo of the galaxy UGC 00180, a galaxy analogous to M31 located at ˜150 Mpc, by obtaining a radial profile of surface brightness down to μ r ˜ 33 mag arcsec-2. This depth is similar to that obtained using the star-counts techniques for Local Group galaxies, but is achieved at a distance where this technique is unfeasible. We find that the mass of the stellar halo of this galaxy is ˜4 × 109 M ⊙, I.e., (3 ± 1)% of the total stellar mass of the whole system. This amount of mass in the stellar halo is in agreement with current theoretical expectations for galaxies of this kind.

  13. Macrocyclic triamine derived glucose analogues for 99m Tc(CO)3 labeling: synthesis and biological evaluation as potential tumor-imaging agents.

    PubMed

    Liu, Teli; Gan, Qianqian; Zhang, Junbo

    2017-02-01

    [ 99m Tc(CO) 3 (H 2 O) 3 ] + has attracted great attention among 99m Tc-labeling techniques, due to its ease of preparation, readily substituted water molecules of the precursor fac-[ 99m Tc(CO) 3 (H 2 O) 3 ] + by a variety of functional groups, small size and inertness. Bifunctional chelator based on a macrocyclic polyamine framework shows easy complexation with [ 99m Tc(CO) 3 (H 2 O) 3 ] + to produce stable complex. In this study, two novel 1, 5, 9-triazacyclododecane derivatives containing a glucose group (6 and 7) were successfully synthesized by reacting different glucose-azides with alkyne-[12]aneN 3 via the so-called click chemistry and radiolabeled with [ 99m Tc(CO) 3 (H 2 O) 3 ] + to form 99m Tc(CO) 3 -6 (C-1-substituted complex) and 99m Tc(CO) 3 -7 (C-2-substituted complex) in high yields. The complexes were stable in vitro over 6 h when incubated in saline at room temperature and in mouse serum at 37 °C. The partition coefficient results showed that they were hydrophilic. The biodistribution studies in Kunming mice bearing S 180 tumor showed both complexes showed accumulation in the tumor. Between them, 99m Tc(CO) 3 -7 had the advantages of much higher tumor uptake and tumor/muscle ratio. Compared with other reported 99m Tc-radiolabeled glucose derivatives, 99m Tc(CO) 3 -7 also showed a higher tumor uptake and tumor/muscle ratio, suggesting it would be a potential candidate for further development as a tumor-imaging agent. © 2017 John Wiley & Sons A/S.

  14. OAT3-mediated extrusion of the 99mTc-ECD metabolite in the mouse brain

    PubMed Central

    Kikuchi, Tatsuya; Okamura, Toshimitsu; Wakizaka, Hidekatsu; Okada, Maki; Odaka, Kenichi; Yui, Joji; Tsuji, Atsushi B; Fukumura, Toshimitsu; Zhang, Ming-Rong

    2014-01-01

    After administration of the 99mTc complex with N,N'-1,2-ethylenediylbis-L-cysteine diethyl ester (99mTc-ECD), a brain perfusion imaging agent, the radioactive metabolite is trapped in primate brain, but not in mouse and rat. Here, we investigate the involvement of metabolite extrusion by organic anion transporter 3 (OAT3), which is highly expressed at the blood–brain barrier in mice, in this species difference. The efflux rate of radioactivity in the cerebrum of Oat3−/− mice at later phase was 20% of that of control mice. Thus, organic anion transporters in mouse brain would be involved in the low brain retention of radioactivity after 99mTc-ECD administration. PMID:24496177

  15. FastMag: Fast micromagnetic simulator for complex magnetic structures (invited)

    NASA Astrophysics Data System (ADS)

    Chang, R.; Li, S.; Lubarda, M. V.; Livshitz, B.; Lomakin, V.

    2011-04-01

    A fast micromagnetic simulator (FastMag) for general problems is presented. FastMag solves the Landau-Lifshitz-Gilbert equation and can handle multiscale problems with a high computational efficiency. The simulator derives its high performance from efficient methods for evaluating the effective field and from implementations on massively parallel graphics processing unit (GPU) architectures. FastMag discretizes the computational domain into tetrahedral elements and therefore is highly flexible for general problems. The magnetostatic field is computed via the superposition principle for both volume and surface parts of the computational domain. This is accomplished by implementing efficient quadrature rules and analytical integration for overlapping elements in which the integral kernel is singular. Thus, discretized superposition integrals are computed using a nonuniform grid interpolation method, which evaluates the field from N sources at N collocated observers in O(N) operations. This approach allows handling objects of arbitrary shape, allows easily calculating of the field outside the magnetized domains, does not require solving a linear system of equations, and requires little memory. FastMag is implemented on GPUs with ?> GPU-central processing unit speed-ups of 2 orders of magnitude. Simulations are shown of a large array of magnetic dots and a recording head fully discretized down to the exchange length, with over a hundred million tetrahedral elements on an inexpensive desktop computer.

  16. [(99m)Tc(CO)(3)]-radiolabeled bevacizumab: in vitro and in vivo evaluation in a melanoma model.

    PubMed

    Camacho, Ximena; García, María Fernanda; Calzada, Victoria; Fernández, Marcelo; Chabalgoity, Jose A; Moreno, Maria; Barbosa de Aguiar, Rodrigo; Alonso, Omar; Gambini, Juan Pablo; Chammas, Roger; Cabral, Pablo

    2013-01-01

    Vascular endothelial growth factor (VEGF) is one of the classic factors to tumor-induced angiogenesis in several tumor types, including melanoma. Bevacizumab, a monoclonal antibody against VEGF, could be used as an imaging tool in preclinical studies. To radiolabel bevacizumab with [(99m)Tc(CO)3(OH2)3](+) and evaluate it in vivo and in vitro for melanoma imaging properties. Bevacizumab was radiolabeled with [(99m)Tc(CO)3(OH2)3](+) ion in saline. The radiochemical stability of the labeled antibody was assessed. The biodistribution and scintigraphy imaging of the radiolabeled antibody were evaluated in normal C57BL/6J mice and in C57BL/6J mice bearing murine B16F1 melanoma tumors. Immunoreactivity of bevacizumab to murine tumors was determined from direct immunofluorescence and immunoblotting assays. We demonstrate that (99m)Tc(CO)3-bevacizumab was stable. In vivo biodistribution studies revealed that tumor uptake of (99m)Tc(CO)3-bevacizumab was 2.64 and 2.51 %ID/g at 4 and 24 h postinjection. Scintigraphy image studies showed tumor selective uptake of (99m)Tc(CO)3-bevacizumab in the tumor-bearing mice. This affinity was confirmed by immunoassays performed on B16F10 tumor samples. (99m)Tc(CO)3-bevacizumab could be used as an approach for tumor nuclear imaging in preclinical studies. This should be useful to provide insights into the angiogenic stimulus before and after chemotherapy, which might help improve current antitumor therapy. Copyright © 2013 S. Karger AG, Basel.

  17. A background correction algorithm for Van Allen Probes MagEIS electron flux measurements

    DOE PAGES

    Claudepierre, S. G.; O'Brien, T. P.; Blake, J. B.; ...

    2015-07-14

    We describe an automated computer algorithm designed to remove background contamination from the Van Allen Probes Magnetic Electron Ion Spectrometer (MagEIS) electron flux measurements. We provide a detailed description of the algorithm with illustrative examples from on-orbit data. We find two primary sources of background contamination in the MagEIS electron data: inner zone protons and bremsstrahlung X-rays generated by energetic electrons interacting with the spacecraft material. Bremsstrahlung X-rays primarily produce contamination in the lower energy MagEIS electron channels (~30–500 keV) and in regions of geospace where multi-M eV electrons are present. Inner zone protons produce contamination in all MagEIS energymore » channels at roughly L < 2.5. The background-corrected MagEIS electron data produce a more accurate measurement of the electron radiation belts, as most earlier measurements suffer from unquantifiable and uncorrectable contamination in this harsh region of the near-Earth space environment. These background-corrected data will also be useful for spacecraft engineering purposes, providing ground truth for the near-Earth electron environment and informing the next generation of spacecraft design models (e.g., AE9).« less

  18. Binding specificity of anti-HNK-1 IgM M-protein in anti-MAG neuropathy: possible clinical relevance.

    PubMed

    Hamada, Yukihiro; Hirano, Makito; Kuwahara, Motoi; Samukawa, Makoto; Takada, Kazuo; Morise, Jyoji; Yabuno, Keiko; Oka, Shogo; Kusunoki, Susumu

    2015-02-01

    Anti-myelin-associated-glycoprotein (MAG) neuropathy is an intractable autoimmune polyneuropathy. The antigenic region of MAG is the human natural killer-1 (HNK-1) carbohydrate. We and others previously suggested that the extension of antibody reactivities to HNK-1-bearing proteins other than MAG was associated with treatment resistance, without statistical analyses. In this study, we established an ELISA method with recombinant proteins to test binding specificities of currently available monoclonal antibodies to MAG and another HNK-1-bearing protein, phosphacan. Using this system, we found the distinct binding specificities of anti-MAG antibody in 19 patients with anti-MAG neuropathy. Their clinical relevance was then determined retrospectively with the adjusted 10-points INCAT disability score (0 = normal and 10 = highly disable). The results showed that strong reactivities of anti-MAG antibodies to phosphacan were significantly associated with treatment resistance or progressive clinical courses, indicating a possible clinical relevance of the binding specificities. Copyright © 2014 Elsevier Ireland Ltd and the Japan Neuroscience Society. All rights reserved.

  19. Pathogenesis and Treatment of Anti-MAG Neuropathy.

    PubMed

    Dalakas, Marinos C

    2010-03-01

    Polyneuropathies associated with IgM monoclonal gammopathies comprise a distinct entity. In spite of the apparent pathogenicity of the IgM antibodies and the specific immunoreactivity to myelin antigens, the disease has been difficult to treat. This review describes the clinical phenotype, addresses recent data on immunoreactivity of IgM to various nerve antigens, and discusses the latest progress on treatment.Most of these patients present with paresthesias and sensory ataxia followed by a varying degree of sensorimotor deficits. In more than 75% of the patients, the monoclonal IgM recognizes myelin-associated glycoprotein (MAG) and sulfoglucuronyl glycosphingolipid (SGPG), best detected by ELISA, or other peripheral nerve glycolipids. Recent experiments have demonstrated that animals immunized with SGPG develop sensory ataxia, suggesting a pathogenic role for this antigen. Although cladribine, cyclophosphamide with prednisone, and intravenous immunoglobulin have offered transient benefits to some patients, most have remained treatment-resistant. Open label studies and a recent randomized controlled trial indicate that rituximab is emerging as the best agent available, providing long-term benefits to almost half of these patients. Rituximab appears to work by suppressing the IgM as well as the anti-MAG antibodies and by inducing immunoregulatory T cells. Patients with more sensory deficits and higher anti-MAG antibodies are more likely to respond but may require re-treatment after several months.These encouraging results need confirmation with a larger trial. Data on long-term efficacy and immune markers associated with response to therapy or need for re-treatment are still needed.

  20. Detecting De-gelation through Tissue Using Magnetically Modulated Optical Nanoprobes (MagMOONs)

    PubMed Central

    Nguyen, KhanhVan T.; Anker, Jeffrey N.

    2014-01-01

    Alginate gels are widely used for drug delivery and implanted devices. The rate at which these gels break down is important for controlling drug release. Since the de-gelation may be different in vivo, monitoring this process in situ is essential. However, it is challenging to monitor the gel through tissue due to optical scattering and tissue autofluorescence. Herein we describe a method to detect through tissue the chemically-induced changes in viscosity and de-gelation process of alginate gels using magnetically modulated optical nanoprobes (MagMOONs). The MagMOONs are fluorescent magnetic microspheres coated with a thin layer of opaque metal on one hemisphere. The metal layer prevents excitation and emission light from passing through one side of the MagMOONs, which creates orientation-dependent fluorescence intensity. The magnetic particles also align in an external magnetic field and give blinking signals when they rotate to follow an external modulated magnetic field. The blinking signals from these MagMOONs are distinguished from background autofluorescence and can be tracked on a single particle level in the absence of tissue, or for an ensemble average of particles blinking through tissue. When these MagMOONs are dispersed in calcium alginate gel, they become sensors for detecting gel degradation upon addition of either ammonium ion or alginate lyase. Our results show MagMOONs start blinking approximately 10 minutes after 2 mg/mL alginate lyase addition and this blinking is clearly detected even through up to 4 mm chicken breast. This approach can potentially be employed to detect bacterial biofilm formation on medical implants by sensing specific proteases that either activate a related function or regulate biofilm formation. It can also be applied to other biosensors and drug delivery systems based on enzyme-catalyzed breakdown of gel components. PMID:26273129

  1. Detecting De-gelation through Tissue Using Magnetically Modulated Optical Nanoprobes (MagMOONs).

    PubMed

    Nguyen, KhanhVan T; Anker, Jeffrey N

    2014-12-15

    Alginate gels are widely used for drug delivery and implanted devices. The rate at which these gels break down is important for controlling drug release. Since the de-gelation may be different in vivo , monitoring this process in situ is essential. However, it is challenging to monitor the gel through tissue due to optical scattering and tissue autofluorescence. Herein we describe a method to detect through tissue the chemically-induced changes in viscosity and de-gelation process of alginate gels using magnetically modulated optical nanoprobes (MagMOONs). The MagMOONs are fluorescent magnetic microspheres coated with a thin layer of opaque metal on one hemisphere. The metal layer prevents excitation and emission light from passing through one side of the MagMOONs, which creates orientation-dependent fluorescence intensity. The magnetic particles also align in an external magnetic field and give blinking signals when they rotate to follow an external modulated magnetic field. The blinking signals from these MagMOONs are distinguished from background autofluorescence and can be tracked on a single particle level in the absence of tissue, or for an ensemble average of particles blinking through tissue. When these MagMOONs are dispersed in calcium alginate gel, they become sensors for detecting gel degradation upon addition of either ammonium ion or alginate lyase. Our results show MagMOONs start blinking approximately 10 minutes after 2 mg/mL alginate lyase addition and this blinking is clearly detected even through up to 4 mm chicken breast. This approach can potentially be employed to detect bacterial biofilm formation on medical implants by sensing specific proteases that either activate a related function or regulate biofilm formation. It can also be applied to other biosensors and drug delivery systems based on enzyme-catalyzed breakdown of gel components.

  2. Targeted disruption of TC-PTP in the proliferative compartment augments STAT3 and AKT signaling and skin tumor development.

    PubMed

    Lee, Hyunseung; Kim, Mihwa; Baek, Minwoo; Morales, Liza D; Jang, Ik-Soon; Slaga, Thomas J; DiGiovanni, John; Kim, Dae Joon

    2017-03-21

    Tyrosine phosphorylation is a vital mechanism that contributes to skin carcinogenesis. It is regulated by the counter-activities of protein tyrosine kinases (PTKs) and protein tyrosine phosphatases (PTPs). Here, we report the critical role of T-cell protein tyrosine phosphatase (TC-PTP), encoded by Ptpn2, in chemically-induced skin carcinogenesis via the negative regulation of STAT3 and AKT signaling. Using epidermal specific TC-PTP knockout (K14Cre.Ptpn2 fl/fl ) mice, we demonstrate loss of TC-PTP led to a desensitization to tumor initiator 7,12-dimethylbenz[a]anthracene (DMBA)-induced apoptosis both in vivo epidermis and in vitro keratinocytes. TC-PTP deficiency also resulted in a significant increase in epidermal thickness and hyperproliferation following exposure to the tumor promoter, 12-O-tetradecanoylphorbol-13-acetate (TPA). Western blot analysis showed that both phosphorylated STAT3 and phosphorylated AKT expressions were significantly increased in epidermis of TC-PTP-deficient mice compared to control mice following TPA treatment. Inhibition of STAT3 or AKT reversed the effects of TC-PTP deficiency on apoptosis and proliferation. Finally, TC-PTP knockout mice showed a shortened latency of tumorigenesis and significantly increased numbers of tumors during two-stage skin carcinogenesis. Our findings reveal that TC-PTP has potential as a novel target for the prevention of skin cancer through its role in the regulation of STAT3 and AKT signaling.

  3. Targeted disruption of TC-PTP in the proliferative compartment augments STAT3 and AKT signaling and skin tumor development

    PubMed Central

    Lee, Hyunseung; Kim, Mihwa; Baek, Minwoo; Morales, Liza D.; Jang, Ik-Soon; Slaga, Thomas J.; DiGiovanni, John; Kim, Dae Joon

    2017-01-01

    Tyrosine phosphorylation is a vital mechanism that contributes to skin carcinogenesis. It is regulated by the counter-activities of protein tyrosine kinases (PTKs) and protein tyrosine phosphatases (PTPs). Here, we report the critical role of T-cell protein tyrosine phosphatase (TC-PTP), encoded by Ptpn2, in chemically-induced skin carcinogenesis via the negative regulation of STAT3 and AKT signaling. Using epidermal specific TC-PTP knockout (K14Cre.Ptpn2fl/fl) mice, we demonstrate loss of TC-PTP led to a desensitization to tumor initiator 7,12-dimethylbenz[a]anthracene (DMBA)-induced apoptosis both in vivo epidermis and in vitro keratinocytes. TC-PTP deficiency also resulted in a significant increase in epidermal thickness and hyperproliferation following exposure to the tumor promoter, 12-O-tetradecanoylphorbol-13-acetate (TPA). Western blot analysis showed that both phosphorylated STAT3 and phosphorylated AKT expressions were significantly increased in epidermis of TC-PTP-deficient mice compared to control mice following TPA treatment. Inhibition of STAT3 or AKT reversed the effects of TC-PTP deficiency on apoptosis and proliferation. Finally, TC-PTP knockout mice showed a shortened latency of tumorigenesis and significantly increased numbers of tumors during two-stage skin carcinogenesis. Our findings reveal that TC-PTP has potential as a novel target for the prevention of skin cancer through its role in the regulation of STAT3 and AKT signaling. PMID:28322331

  4. What's in a Name?FRAMING:Martin-Bradshaw DYSfunctionality = Siegel ``Buzzwordism,Bandwagonism&Sloganeering For: Fun, Profit,Survival,Ego": From SOC to FLT Proof to High-Tc to Spintronics to Giant-Magnetoresistance: Ethics??? SHMETHICS!!! Rampant Sociolog

    NASA Astrophysics Data System (ADS)

    Siegel, Edward

    2008-03-01

    Buzzwordism,Bandwagonism,Sloganeering for:Fun,Profit,Survival, Ego=ethics DYSunctionality: Digits log-law: Siegel INVERSION: bosons=digits; Excluded d=0? P(0)=oo V P(1)Tc! Emery SC 3-band V Siegel multi-band Hubbard-mdls[J.Mag.Mag. Mtls.(1976-1980);APS March Mtgs.,1987-on];Intl.Conf.High-Tc:Stanford,1987;Berkeley,1987); WorldCong.SC, 1992]: 1970s<1993! Anderson SC RVB V Overhauser CORRECT SS/CDWs:1960s<1987. Fert-Grunberg GMR V decade-earlier Siegel[JMMM.7,31(1978);Mayo,Village Voice,p.40(8/21/78):1978<1988!!!A la Brian Martin-John Bradshaw addictions 12-step recovery programs[Healing SHAME That BINDS YOU]: One is only as SICK as one's SECRETS! Ethics? SHMETHICS! RAMPANT ethical DYSfunctionality!!!

  5. MagIC: Fluid dynamics in a spherical shell simulator

    NASA Astrophysics Data System (ADS)

    Wicht, J.; Gastine, T.; Barik, A.; Putigny, B.; Yadav, R.; Duarte, L.; Dintrans, B.

    2017-09-01

    MagIC simulates fluid dynamics in a spherical shell. It solves for the Navier-Stokes equation including Coriolis force, optionally coupled with an induction equation for Magneto-Hydro Dynamics (MHD), a temperature (or entropy) equation and an equation for chemical composition under both the anelastic and the Boussinesq approximations. MagIC uses either Chebyshev polynomials or finite differences in the radial direction and spherical harmonic decomposition in the azimuthal and latitudinal directions. The time-stepping scheme relies on a semi-implicit Crank-Nicolson for the linear terms of the MHD equations and a Adams-Bashforth scheme for the non-linear terms and the Coriolis force.

  6. Status analysis of keyhole bottom in laser-MAG hybrid welding process.

    PubMed

    Wang, Lin; Gao, Xiangdong; Chen, Ziqin

    2018-01-08

    The keyhole status is a determining factor of weld quality in laser-metal active gas arc (MAG) hybrid welding process. For a better evaluation of the hybrid welding process, three different penetration welding experiments: partial penetration, normal penetration (or full penetration), and excessive penetration were conducted in this work. The instantaneous visual phenomena including metallic vapor, spatters and keyhole of bottom surface were used to evaluate the keyhole status by a double high-speed camera system. The Fourier transform was applied on the bottom weld pool image for removing the image noise around the keyhole, and then the bottom weld pool image was reconstructed through the inverse Fourier transform. Lastly, the keyhole bottom was extracted from the de-noised bottom weld pool image. By analyzing the visual features of the laser-MAG hybrid welding process, mechanism of the closed and opened keyhole bottom were revealed. The results show that the stable opened or closed status of keyhole bottom is directly affected by the MAG droplet transition in the normal penetration welding process, and the unstable opened or closed status of keyhole bottom would appear in excessive penetration welding and partial penetration welding. The analysis method proposed in this paper could be used to monitor the keyhole stability in laser-MAG hybrid welding process.

  7. Monitoring Tc dynamics in a bioreduced sediment: an investigation with gamma camera imaging of (99m)Tc-pertechnetate and (99m)Tc-DTPA.

    PubMed

    Vandehey, Nicholas T; O'Neil, James P; Slowey, Aaron J; Boutchko, Rostyslav; Druhan, Jennifer L; Moses, William W; Nico, Peter S

    2012-11-20

    We demonstrate the utility of nuclear medical imaging technologies and a readily available radiotracer, [(99m)Tc]TcO(4)(-), for the noninvasive monitoring of Fe(II) production in acetate-stimulated sediments from Old Rifle, CO, USA. Microcosms consisting of sediment in artificial groundwater media amended with acetate were probed by repeated injection of radiotracer over three weeks. Gamma camera imaging was used to noninvasively quantify the rate and extent of [(99m)Tc]TcO(4)(-) partitioning from solution to sediment. Aqueous Fe(II) and sediment-associated Fe(II) were also measured and correlated with the observed tracer behavior. For each injection of tracer, curves of (99m)Tc concentration in solution vs time were fitted to an analytic function that accounts for both the observed rate of sedimentation as well as the rate of (99m)Tc association with the sediment. The rate and extent of (99m)Tc association with the biostimulated sediment correlated well with the production of Fe(II), and a mechanism of [(99m)Tc]TcO(4)(-) reduction via reaction with surface-bound Fe(II) to form an immobile Tc(IV) species was inferred. After three weeks of bioreduction, a subset of microcosms was aerated in order to reoxidize the Fe(II) to Fe(III), which also destroyed the affinity of the [(99m)Tc]TcO(4)(-) for the sediments. However, within 3 days postoxidation, the rate of Tc(VII) reduction was faster than immediately before oxidation implying a rapid return to more extensive bioreduction. Furthermore, aeration soon after a tracer injection showed that sediment-bound Tc(IV) is rapidly resolubilized to Tc(VII). In contrast to the [(99m)Tc]TcO(4)(-), a second commercially available tracer, (99m)Tc-DTPA (diethylenetriaminepentaacetic acid), had minimal association with sediment in both controls and biostimulated sediments. These experiments show the promise of [(99m)Tc]TcO(4)(-) and (99m)Tc-DTPA as noninvasive imaging probes for a redox-sensitive radiotracer and a conservative flow

  8. Development and Application of an Indirect Enzyme-Linked Immunosorbent Assay Using Recombinant Mag1 for Serodiagnosis of Toxoplasma gondii In Dogs.

    PubMed

    Zhuo, Xunhui; Sun, Hongchao; Zhang, Zhi; Luo, Jiaqing; Shan, Ying; Du, Aifang

    2017-06-01

    Serologic tests are widely accepted and applied as means to detect anti- Toxoplasma gondii immunoglobulin G antibodies. In this study, recombinant matrix antigen (rMAG1) was induced by isopropyl-β-d-thiogalactoside and purified by nickel-nitrilotriacetic acid purification system. We then developed and optimized an indirect enzyme-linked immunosorbent assay (ELISA) through checkerboard assays using serial dilutions of antigens and sera to assess the potential use of rMAG1 in serologic detection of T. gondii infection in dogs. Serum samples from 93 domestic dogs were analyzed by western blot and rMAG1-ELISA. The results were compared with those obtained from an ELISA with the soluble Toxoplasma lysate antigens (TLA). We found that although yielding an excellent agreement (96.7%) with western blot data (κ = 0.9659), rMAG1-ELISA produced higher sensitivity (93.9% vs. 87.8%) and specificity (98.3% vs. 96.7%) than TLA-ELISA. In addition, receiver operating characteristic analysis also revealed that rMAG1-ELISA is in more agreement with western blot (area under the curve [AUC] = 0.985) relative to TLA-ELISA (AUC = 0.955). These results indicated that the rMAG1-ELISA established in this study provides a promising and reliable tool for serologic detection of T. gondii infection in dogs.

  9. Identification of novel mammalian hosts and Brazilian biome geographic distribution of Trypanosoma cruzi TcIII and TcIV.

    PubMed

    Barros, Juliana Helena S; Xavier, Samanta Cristina C; Bilac, Daniele; Lima, Valdirene Santos; Dario, Maria Augusta; Jansen, Ana Maria

    2017-08-01

    Trypanosoma cruzi is a parasitic protozoan responsible for Chagas disease. Seven different Discrete Typing Units (DTUs) of T. cruzi are currently identified in nature: TcI-TcVI, and TcBat whose distribution patterns in nature, hosts/reservoirs and eco-epidemiological importance are still little known. Here, we present novel data on the geographic distribution and diversity of mammalian hosts and vectors of T. cruzi DTUs TcIII and TcIV. In this study, we analyzed 61 T. cruzi isolates obtained from 18 species of mammals (five orders) and two Hemiptera genera. Samples were collected from five Brazilian biomes (Pantanal, Caatinga, Cerrado, Atlantic Rainforest, and Amazon) previously characterized as Z3 or mixed infection (TcI-Z3) by mini-exon gene PCR. To identify TcIII and TcIV genotypes, we applied restriction fragment length polymorphism analysis to the PCR-amplified histone 3 gene. DTUs TcIII and TcIV were identified in single and mixed infections from wide dispersion throughout five Brazilian biomes studied, with TcIV being the most common. Pantanal was the biome that displayed the largest number of samples characterized as TcIII and TcIV in single and mixed infections, followed by Atlantic Rainforest and Amazon. Species from the Didelphimorphia order displayed the highest frequency of infection and were found in all five biomes. We report, for the first time, the infection of a species of the Artiodactyla order by DTU TcIII. In addition, we describe new host species: five mammals (marsupials and rodents) and two genera of Hemiptera. Our data indicate that DTUs TcIII and TcIV are more widespread and infect a larger number of mammalian species than previously thought. In addition, they are transmitted in restricted foci and cycles, but in different microhabitats and areas with distinct ecological profiles. Finally, we show that DTUs TcIII and TcIV do not present any specific association with biomes or host species. Copyright © 2017. Published by Elsevier B.V.

  10. Assessing activation of hepatic stellate cells by (99m)Tc-3PRGD2 scintigraphy targeting integrin αvβ3: a feasibility study.

    PubMed

    Zhang, Xin; Xin, Jun; Shi, Yu; Xu, Weina; Yu, Shupeng; Yang, Zhiguang; Liu, Changping; Cao, Li; Guo, Qiyong

    2015-03-01

    Hepatic stellate cell (HSC) activation, which is accompanied by increased expression of integrin αvβ3, is an important factor in liver fibrogenesis. Molecular imaging targeting the integrin αvβ3 could provide a non-invasive method for evaluating the expression and the function of the integrin αvβ3 on the activated HSCs (aHSCs) in the injured liver, and then provide important prognostic information. (99m)Tc-3PRGD2 is such a radiotracer specific for integrin αvβ3. In this study, we aimed to compare the differences in liver uptake and retention of the (99m)Tc-3PRGD2 between normal liver and injured liver to evaluate the feasibility of (99m)Tc-3PRGD2 scintigraphy for this purpose. We used planar scintigraphy to assess changes in integrin αvβ3 binding of intravenously-administered (99m)Tc-3PRGD2 in the livers of rats with thioacetamide (TAA)-induced liver fibrosis compared with the controls. We co-injected cold c(RGDyK) with (99m)Tc-3PRGD2 to assess the specific binding of the radiotracer. We performed Sirius red staining to assess liver fibrosis, immunofluorescent colocalization to identify the location of integrin αvβ3 expressed in the fibrotic liver, and we measured protein and messenger RNA expression of integrin αvβ3 and alpha smooth muscle actin (α-SMA) in the control and fibrotic livers. The fibrotic livers showed enhanced (99m)Tc-3PRGD2 uptake and retention. The radiotracer was demonstrated to bind specifically with the integrin αvβ3 mainly expressed on the aHSCs. The liver-to-heart ratio at 30 min post-injection was higher in the fibrotic livers than in the control livers (TAA, 1.98±0.08 vs. control, 1.50±0.12, p<0.01). The liver t1/2 was longer than in the controls (TAA, 27.07±10.69 min vs. control, 12.67±4.10 min, p<0.01). The difference of heart t1/2 between the two groups was not statistically significant (TAA, 3.13±0.63 min vs. control, 3.41±0.77 min, p=0.94). (99m)Tc-3PRGD2 molecular imaging can provide a non-invasive method for

  11. The discovery of robust magnetism in a technetium oxide: The structure of CaTcO3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Avdeev, Maxim; Thorogood, Gordon J.; Carter, Melody L.

    The technetium perovskite CaTcO{sub 3} has been synthesized. Combining synchrotron X-ray and neutron diffraction, we found that CaTcO{sub 3} is an antiferromagnetic with a surprisingly high Neel temperature of 800 K. The transition to the magnetic state does not involve a structural change, but there is obvious magnetostriction. Electronic structure calculations confirm the experimental results.

  12. In Vitro/In Vivo Evaluation of Radiolabeled [(99m)Tc(CO)3](+)-Hydroxyurea and Fluorescein Isothiocyanate-Hydroxyurea.

    PubMed

    Yilmaz, Baris; Teksoz, Serap; Kilcar, Ayfer Yurt; Ucar, Eser; Ichedef, Cigdem; Medine, Emin Ilker; Ari, Kadir

    2016-02-01

    The aim of current study is to examine hydroxyurea (HU), which is an antineoplastic drug used for the treatment of leukemia, sickle-cell disease, HIV, psoriasis, thrombocythemia, and various neoplastic diseases in two aspects. The active ingredient hydroxyurea was obtained by purification of the capsule form drug, commercially named as HYDREA. Then, [(99m)Tc(CO)3](+)core radiolabeling with HU was performed as first aspect. Quality control studies of (99m)Tc(CO)3-HU complex were performed by thin-layer radiochromatography and high-performance liquid radiochromatography methods. The results demonstrated that the radiolabeling yield was quite high (98.43% ± 2.29%). Also, (99m)Tc(CO)3-HU complex has good stability during the 24-hour period. Biological behavior of (99m)Tc(CO)3-HU complex is evaluated by biodistribution studies on Wistar Albino rats. Fluorescein isothiocyanate (FITC) labeling of HU was performed as second aspect. Fluorometric evaluation of binding efficacy and fluorescence imaging studies on MCF7 and Hela cell lines were carried out. It was thought that the knowledge achieved in this study would contribute to using (99m)Tc(CO)3-HU complex as an imaging agent, which inhibits the DNA synthesis selectively, by inhibiting ribonucleotide reductase enzyme. It was observed that FITC-HU has noteworthy incorporation on both cell lines.

  13. MagAO: Status and on-sky performance of the Magellan adaptive optics system

    NASA Astrophysics Data System (ADS)

    Morzinski, Katie M.; Close, Laird M.; Males, Jared R.; Kopon, Derek; Hinz, Phil M.; Esposito, Simone; Riccardi, Armando; Puglisi, Alfio; Pinna, Enrico; Briguglio, Runa; Xompero, Marco; Quirós-Pacheco, Fernando; Bailey, Vanessa; Follette, Katherine B.; Rodigas, T. J.; Wu, Ya-Lin; Arcidiacono, Carmelo; Argomedo, Javier; Busoni, Lorenzo; Hare, Tyson; Uomoto, Alan; Weinberger, Alycia

    2014-07-01

    MagAO is the new adaptive optics system with visible-light and infrared science cameras, located on the 6.5-m Magellan "Clay" telescope at Las Campanas Observatory, Chile. The instrument locks on natural guide stars (NGS) from 0th to 16th R-band magnitude, measures turbulence with a modulating pyramid wavefront sensor binnable from 28×28 to 7×7 subapertures, and uses a 585-actuator adaptive secondary mirror (ASM) to provide at wavefronts to the two science cameras. MagAO is a mutated clone of the similar AO systems at the Large Binocular Telescope (LBT) at Mt. Graham, Arizona. The high-level AO loop controls up to 378 modes and operates at frame rates up to 1000 Hz. The instrument has two science cameras: VisAO operating from 0.5-1μm and Clio2 operating from 1-5 μm. MagAO was installed in 2012 and successfully completed two commissioning runs in 2012-2013. In April 2014 we had our first science run that was open to the general Magellan community. Observers from Arizona, Carnegie, Australia, Harvard, MIT, Michigan, and Chile took observations in collaboration with the MagAO instrument team. Here we describe the MagAO instrument, describe our on-sky performance, and report our status as of summer 2014.

  14. Imaging prostate cancer (PCa) with [99m Tc(CO)3 ]finasteride dithiocarbamate.

    PubMed

    Shah, Syed Qaiser; Gul-E-Raana; Uddin, Ghias

    2018-06-15

    This investigation aimed to modify finasteride (1) to finasteride dithiocarbamate (2) for subsequent synthesis of the rhenium analogue (3) and [ 99m Tc]tricarbonyl complexes (4), to assess its prostate cancer (PCa) targeting potential in a rat model. To validate the identity of (4), reference (3) has been synthesized by using fac-[Net 4 ] 2 [ReBr 3 (CO) 3 ] precursor and characterized by 1 H-NMR, 13 C-NMR, ESI-MS, and elemental analysis. The analogue (4) was synthesized by using fac-[ 99m Tc(H 2 O) 3 (CO) 3 ] + precursor, and its structure was confirmed by comparative HPLC by using (3) as a reference. Further, the suitability of (4) as a PCa imaging agent was investigated in vitro and in vivo. At room temperature, (4) had ≥99% radiochemical purity and remained ≥84% stable in serum. In preclinical studies, biodistribution of (4) in histopathologically established rat model showed adequately high in vivo uptake in the prostate attracting the possibility of using it for noninvasive imaging of PCa. Copyright © 2018 John Wiley & Sons, Ltd.

  15. The CrowdMag App - turning your smartphone into a travelling magnetic observatory

    NASA Astrophysics Data System (ADS)

    Saltus, Richard; Nair, Manoj

    2017-04-01

    In 2014, we started the "CrowdMag" Project to collect vector magnetic data from digital magnetometers in smartphones. In October 2014, we released our first-generation Android and iOS apps. Currently, the CrowdMag Project has more than 15,000 enthusiastic users contributing more than 12 million magnetic data points from around the world. NOAA's National Centers for Environmental Information (NCEI), in partnership with the University of Colorado's Cooperative Institute for Research in the Environmental Sciences (CIRES) develops magnetic field models to aid navigation, resource exploration and scientific research. We use observatories, satellites and ship/airborne surveys to measure the magnetic data. However, the measurements leave gaps in coverage, particularly for short-wavelength urban noise. Our ultimate goal is to use data from the CrowdMag Project to improve global magnetic data coverage. Here we present some early results from the analysis of the crowdsourced magnetic data. A global magnetic model derived solely based on CrowdMag data is generally consistent with satellite-derived models such as World Magnetic Model. A unique contribution of the CrowdMag Project is the collection of ground level magnetic data in densely populated regions with an unprecedented spatial resolution. For example, we show a magnetic map (by binning the data collected into 100x100m cells) of central Boulder using 170,000 data points collected by about 60 devices over the duration October 2014- January 2016. The median magnetic field value is consistent with the expected magnitude of the Earth's background magnetic field. The standard deviation of the CrowdMag total field (F) values is much higher than the expected natural (i.e., diurnal and geologic) magnetic field variation. However, the phone's magnetometer is sensitive enough to capture the larger magnitude magnetic signature from the urban magnetic sources. We discuss the reliability of crowdsourced magnetic maps and their

  16. Characteristics of Tc and ρ(T) of polycrystalline (In2O3)-(ZnO) films with low carrier density

    NASA Astrophysics Data System (ADS)

    B, Shinozaki; S, Takada; N, Kokubo; K, Makise; T, Asano; K, Yamada; K, Yano; H, Nakamura

    2012-12-01

    For the polycrystalline (In2O3)-(ZnO) prepared by annealing in air, we investigated the relation among superconductivity, ρ(T) characteristics and preparation conditions. To clarify the distribution of elements, we studied the microstructure by scanning transmission electron microscopy (STEM) and electron energy-loss spectroscopy (EELS). It was found that 1) The films annealed at restricted regions of annealing temperature Ta and time ta show the superconductivity. Transition temperature TC and carrier density n are Tc<3.3K and n asymp1025/m3~1026/m3, respectively. 2) The data on EELS spectra mapping of indium plasmon indicate that droplets of the pure indium phase distribute discretely on grain boundaries and near the interface between the film and the glass substrate. 3) Although data in the Tc - Ta relation are scattered, the TC shows relatively good correlation with n, taking a convex form.

  17. A New Interface for the Magnetics Information Consortium (MagIC) Paleo and Rock Magnetic Database

    NASA Astrophysics Data System (ADS)

    Jarboe, N.; Minnett, R.; Koppers, A. A. P.; Tauxe, L.; Constable, C.; Shaar, R.; Jonestrask, L.

    2014-12-01

    The Magnetic Information Consortium (MagIC) database (http://earthref.org/MagIC/) continues to improve the ease of uploading data, the creation of complex searches, data visualization, and data downloads for the paleomagnetic, geomagnetic, and rock magnetic communities. Data uploading has been simplified and no longer requires the use of the Excel SmartBook interface. Instead, properly formatted MagIC text files can be dragged-and-dropped onto an HTML 5 web interface. Data can be uploaded one table at a time to facilitate ease of uploading and data error checking is done online on the whole dataset at once instead of incrementally in an Excel Console. Searching the database has improved with the addition of more sophisticated search parameters and with the ability to use them in complex combinations. Searches may also be saved as permanent URLs for easy reference or for use as a citation in a publication. Data visualization plots (ARAI, equal area, demagnetization, Zijderveld, etc.) are presented with the data when appropriate to aid the user in understanding the dataset. Data from the MagIC database may be downloaded from individual contributions or from online searches for offline use and analysis in the tab delimited MagIC text file format. With input from the paleomagnetic, geomagnetic, and rock magnetic communities, the MagIC database will continue to improve as a data warehouse and resource.

  18. Uploading, Searching and Visualizing of Paleomagnetic and Rock Magnetic Data in the Online MagIC Database

    NASA Astrophysics Data System (ADS)

    Minnett, R.; Koppers, A.; Tauxe, L.; Constable, C.; Donadini, F.

    2007-12-01

    The Magnetics Information Consortium (MagIC) is commissioned to implement and maintain an online portal to a relational database populated by both rock and paleomagnetic data. The goal of MagIC is to archive all available measurements and derived properties from paleomagnetic studies of directions and intensities, and for rock magnetic experiments (hysteresis, remanence, susceptibility, anisotropy). MagIC is hosted under EarthRef.org at http://earthref.org/MAGIC/ and will soon implement two search nodes, one for paleomagnetism and one for rock magnetism. Currently the PMAG node is operational. Both nodes provide query building based on location, reference, methods applied, material type and geological age, as well as a visual map interface to browse and select locations. Users can also browse the database by data type or by data compilation to view all contributions associated with well known earlier collections like PINT, GMPDB or PSVRL. The query result set is displayed in a digestible tabular format allowing the user to descend from locations to sites, samples, specimens and measurements. At each stage, the result set can be saved and, where appropriate, can be visualized by plotting global location maps, equal area, XY, age, and depth plots, or typical Zijderveld, hysteresis, magnetization and remanence diagrams. User contributions to the MagIC database are critical to achieving a useful research tool. We have developed a standard data and metadata template (version 2.3) that can be used to format and upload all data at the time of publication in Earth Science journals. Software tools are provided to facilitate population of these templates within Microsoft Excel. These tools allow for the import/export of text files and provide advanced functionality to manage and edit the data, and to perform various internal checks to maintain data integrity and prepare for uploading. The MagIC Contribution Wizard at http://earthref.org/MAGIC/upload.htm executes the upload

  19. MAG4 Versus Alternative Techniques for Forecasting Active-Region Flare Productivity

    NASA Technical Reports Server (NTRS)

    Falconer, David A.; Moore, Ronald L.; Barghouty, Abdulnasser F.; Khazanov, Igor

    2014-01-01

    MAG4 (Magnetogram Forecast), developed originally for NASA/SRAG (Space Radiation Analysis Group), is an automated program that analyzes magnetograms from the HMI (Helioseismic and Magnetic Imager) instrument on NASA SDO (Solar Dynamics Observatory), and automatically converts the rate (or probability) of major flares (M- and X-class), Coronal Mass Ejections (CMEs), and Solar Energetic Particle Events. MAG4 does not forecast that a flare will occur at a particular time in the next 24 or 48 hours; rather the probability of one occurring.

  20. Improvements to the Magnetics Information Consortium (MagIC) Paleo and Rock Magnetic Database

    NASA Astrophysics Data System (ADS)

    Jarboe, N.; Minnett, R.; Tauxe, L.; Koppers, A. A. P.; Constable, C.; Jonestrask, L.

    2015-12-01

    The Magnetic Information Consortium (MagIC) database (http://earthref.org/MagIC/) continues to improve the ease of data uploading and editing, the creation of complex searches, data visualization, and data downloads for the paleomagnetic, geomagnetic, and rock magnetic communities. Online data editing is now available and the need for proprietary spreadsheet software is therefore entirely negated. The data owner can change values in the database or delete entries through an HTML 5 web interface that resembles typical spreadsheets in behavior and uses. Additive uploading now allows for additions to data sets to be uploaded with a simple drag and drop interface. Searching the database has improved with the addition of more sophisticated search parameters and with the facility to use them in complex combinations. A comprehensive summary view of a search result has been added for increased quick data comprehension while a raw data view is available if one desires to see all data columns as stored in the database. Data visualization plots (ARAI, equal area, demagnetization, Zijderveld, etc.) are presented with the data when appropriate to aid the user in understanding the dataset. MagIC data associated with individual contributions or from online searches may be downloaded in the tab delimited MagIC text file format for susbsequent offline use and analysis. With input from the paleomagnetic, geomagnetic, and rock magnetic communities, the MagIC database will continue to improve as a data warehouse and resource.

  1. Acute neurological worsening after Rituximab treatment in patients with anti-MAG neuropathy.

    PubMed

    Sala, Emilie; Robert-Varvat, Florence; Paul, Stéphane; Camdessanché, Jean-Philippe; Antoine, Jean-Christophe

    2014-10-15

    Patients with peripheral neuropathy and anti-MAG monoclonal IgM may respond to Rituximab, a humanized monoclonal anti-CD20 antibody. We report on three patients with peripheral neuropathy and anti-MAG monoclonal IgM who deteriorated under Rituximab and reviewed seven previously published cases. Worsening was acute and severe, and occurred during the treatment period. All the patients improved after deterioration but at final evaluation only one was improved comparatively to baseline, five were worsened and four were stabilized. Deterioration was not clearly associated with an increase of the anti-MAG antibody titer. Two patients received Rituximab prior or after the course which induced worsening without adverse reaction. Although rare, acute worsening of the neuropathy can occur after Rituximab. The deterioration is however reversible within some weeks to several months. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. A mucin-like glycoprotein identified by MAG (mouse ascites Golgi) antibodies. Menstrual cycle-dependent localization in human endometrium.

    PubMed Central

    Kliman, H. J.; Feinberg, R. F.; Schwartz, L. B.; Feinman, M. A.; Lavi, E.; Meaddough, E. L.

    1995-01-01

    Human endometrial glands synthesize and secrete a high molecular weight mucin-like glycoprotein in a menstrual cycle-dependent fashion. A novel moiety within this Golgi-associated glycoprotein is strongly reactive with IgG antibodies in numerous murine ascites, and has been termed MAG (mouse ascites Golgi). Immunohistochemical staining of 201 endometrial biopsies revealed the following patterns: MAG first appeared in the Golgi on cycle day 5, peaked on day 15, was present on the surface of the luminal epithelium between days 17 and 19, and was no longer detectable after day 19. MAG was also present in cervical, prostate, seminal vesicle, and lacrimal glands, pancreatic acinar cells, gall bladder and bile duct epithelium, and certain cells of the salivary and sweat glands. Interestingly, only tissues from blood group A individuals exhibited this staining. As a common link among all these cell types is the expression of mucins, we speculated that the MAG epitope could be a mucin-associated blood group A-related epitope. This hypothesis was tested by absorption experiments with a variety of glycoconjugates and erythrocytes and by immunoblots of MAG-rich material. The absorption studies demonstrated that only type III porcine mucin (< 1% sialic acid) and blood type A or AB erythrocytes were able to absorb the anti-MAG antibody. Inasmuch as N-acetyl-galactosamine alone, the terminal blood group A carbohydrate, did not block MAG antibody binding, the MAG epitope appears to involve N-acetylgalactosamine plus other determinants. Immunoblots of endometrial extracts and saliva from blood type A individuals revealed MAG-reactive material with a molecular weight > 200 kd under reducing conditions. Because the MAG epitope appears on the endometrial surface during the purported implantation window, we speculate that mucin-like epitopes could play a role in the earliest apposition phases of conceptus-endometrial interaction. Images Figure 1 Figure 2 Figure 4 Figure 5 Figure 6

  3. Method for generating a crystalline {sup 99}MoO{sub 3} product and the isolation {sup 99m}Tc compositions therefrom

    DOEpatents

    Bennett, R.G.; Christian, J.D.; Kirkham, R.J.; Tranter, T.J.

    1998-09-01

    An improved method is described for producing {sup 99m}Tc compositions. {sup 100}Mo metal is irradiated with photons in a particle (electron) accelerator to produce {sup 99}Mo metal which is dissolved in a solvent. A solvated {sup 99}Mo product is then dried to generate a supply of {sup 99}MoO{sub 3} crystals. The crystals are thereafter heated at a temperature which will sublimate the crystals and form a gaseous mixture containing vaporized {sup 99m}TcO{sub 3} and vaporized {sup 99m}TcO{sub 2} but will not cause the production of vaporized {sup 99}MoO{sub 3}. The mixture is then combined with an oxidizing gas to generate a gaseous stream containing vaporized {sup 99m}Tc{sub 2}O{sub 7}. Next, the gaseous stream is cooled to a temperature sufficient to convert the vaporized {sup 99m}Tc{sub 2}O{sub 7} into a condensed {sup 99m}Tc-containing product. The product has high purity levels resulting from the use of reduced temperature conditions and ultrafine crystalline {sup 99}MoO{sub 3} starting materials with segregated {sup 99m}Tc compositions therein which avoid the production of vaporized {sup 99}MoO{sub 3} contaminants. 1 fig.

  4. Method for generating a crystalline .sup.99 MoO.sub.3 product and the isolation .sup.99m Tc compositions therefrom

    DOEpatents

    Bennett, Ralph G.; Christian, Jerry D.; Kirkham, Robert J.; Tranter, Troy J.

    1998-01-01

    An improved method for producing .sup.99m Tc compositions. .sup.100 Mo metal is irradiated with photons in a particle (electron) accelerator to produce .sup.99 Mo metal which is dissolved in a solvent. A solvated .sup.99 Mo product is then dried to generate a supply of .sup.99 MoO.sub.3 crystals. The crystals are thereafter heated at a temperature which will sublimate the crystals and form a gaseous mixture containing vaporized .sup.99m TcO.sub.3 and vaporized .sup.99m TcO.sub.2 but will not cause the production of vaporized .sup.99 MoO.sub.3. The mixture is then combined with an oxidizing gas to generate a gaseous stream containing vaporized .sup.99m Tc.sub.2 O.sub.7. Next, the gaseous stream is cooled to a temperature sufficient to convert the vaporized .sup.99m Tc.sub.2 O.sub.7 into a condensed .sup.99m Tc-containing product. The product has high purity levels resulting from the use of reduced temperature conditions and ultrafine crystalline .sup.99 MoO.sub.3 starting materials with segregated .sup.99m Tc compositions therein which avoid the production of vaporized .sup.99 MoO.sub.3 contaminants.

  5. Modernizing the MagIC Paleomagnetic and Rock Magnetic Database Technology Stack to Encourage Code Reuse and Reproducible Science

    NASA Astrophysics Data System (ADS)

    Minnett, R.; Koppers, A. A. P.; Jarboe, N.; Jonestrask, L.; Tauxe, L.; Constable, C.

    2016-12-01

    The Magnetics Information Consortium (https://earthref.org/MagIC/) develops and maintains a database and web application for supporting the paleo-, geo-, and rock magnetic scientific community. Historically, this objective has been met with an Oracle database and a Perl web application at the San Diego Supercomputer Center (SDSC). The Oracle Enterprise Cluster at SDSC, however, was decommissioned in July of 2016 and the cost for MagIC to continue using Oracle became prohibitive. This provided MagIC with a unique opportunity to reexamine the entire technology stack and data model. MagIC has developed an open-source web application using the Meteor (http://meteor.com) framework and a MongoDB database. The simplicity of the open-source full-stack framework that Meteor provides has improved MagIC's development pace and the increased flexibility of the data schema in MongoDB encouraged the reorganization of the MagIC Data Model. As a result of incorporating actively developed open-source projects into the technology stack, MagIC has benefited from their vibrant software development communities. This has translated into a more modern web application that has significantly improved the user experience for the paleo-, geo-, and rock magnetic scientific community.

  6. Wounds caused by contact with muzzle-lift relief ports (Mag-Na-Port).

    PubMed

    Rogers, D R; Shem, R J

    1992-12-01

    Fan-shaped stippled burns were produced on the skin when a revolver whose barrel had been modified by the Mag-Na-Port process was fired twice with the side of the muzzle in contact. A grazing wound was produced by one bullet, and an oblique entry was produced by the other. The characteristics of Mag-Na-Port wounds and test shots are described, and these are compared with test shots from two other higher power revolvers.

  7. Biotin avidin amplified magnetic immunoassay for hepatitis B surface antigen detection using GoldMag nanoparticles

    NASA Astrophysics Data System (ADS)

    Yu, An; Geng, Tingting; Fu, Qiang; Chen, Chao; Cui, Yali

    2007-04-01

    Using GoldMag (Fe3O4/Au) nanoparticles as a carrier, a biotin-avidin amplified ELISA was developed to detect hepatitis B surface antigen (HBsAg). A specific antibody was labeled with biotin and then used to detect the antigen with an antibody coated on GoldMag nanoparticles by a sandwich ELISA assay. The results showed that 5 mol of biotin were surface bound per mole of antibody. The biotin-avidin amplified ELISA assay has a higher sensitivity than that of the direct ELISA assay. There is 5-fold difference between HBsAg positive and negative serum even at dilution of 1:10000, and the relative standard deviation of the parallel positive serum at dilution of 1:4000 is 5.98% (n=11).

  8. BEYOND 31 mag arcsec{sup −2}: THE FRONTIER OF LOW SURFACE BRIGHTNESS IMAGING WITH THE LARGEST OPTICAL TELESCOPES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Trujillo, Ignacio; Fliri, Jüergen, E-mail: trujillo@iac.es; Departamento de Astrofísica, Universidad de La Laguna, E-38206, La Laguna, Tenerife

    2016-06-01

    The detection of structures in the sky with optical surface brightnesses fainter than 30 mag arcsec{sup −2} (3 σ in 10 × 10 arcsec boxes; r -band) has remained elusive in current photometric deep surveys. Here we show how present-day telescopes of 10 m class can provide broadband imaging 1.5–2 mag deeper than most previous results within a reasonable amount of time (i.e., <10 hr on-source integration). In particular, we illustrate the ability of the 10.4 m Gran Telescopio de Canarias telescope to produce imaging with a limiting surface brightness of 31.5 mag arcsec{sup −2} (3 σ in 10 ×more » 10 arcsec boxes; r -band) using 8.1 hr on source. We apply this power to explore the stellar halo of the galaxy UGC 00180, a galaxy analogous to M31 located at ∼150 Mpc, by obtaining a radial profile of surface brightness down to μ{sub r} ∼ 33 mag arcsec{sup −2}. This depth is similar to that obtained using the star-counts techniques for Local Group galaxies, but is achieved at a distance where this technique is unfeasible. We find that the mass of the stellar halo of this galaxy is ∼4 × 10{sup 9} M {sub ⊙}, i.e., (3 ± 1)% of the total stellar mass of the whole system. This amount of mass in the stellar halo is in agreement with current theoretical expectations for galaxies of this kind.« less

  9. Assessment of hydraulic performance and biocompatibility of a MagLev centrifugal pump system designed for pediatric cardiac or cardiopulmonary support.

    PubMed

    Dasse, Kurt A; Gellman, Barry; Kameneva, Marina V; Woolley, Joshua R; Johnson, Carl A; Gempp, Thomas; Marks, John D; Kent, Stella; Koert, Andrew; Richardson, J Scott; Franklin, Steve; Snyder, Trevor A; Wearden, Peter; Wagner, William R; Gilbert, Richard J; Borovetz, Harvey S

    2007-01-01

    The treatment of children with life-threatening cardiac and cardiopulmonary failure is a large and underappreciated public health concern. We have previously shown that the CentriMag is a magnetically levitated centrifugal pump system, having the utility for treating adults and large children (1,500 utilized worldwide). We present here the PediVAS, a pump system whose design was modified from the CentriMag to meet the physiological requirements of young pediatric and neonatal patients. The PediVAS is comprised of a single-use centrifugal blood pump, reusable motor, and console, and is suitable for right ventricular assist device (RVAD), left ventricular assist device (LVAD), biventricular assist device (BVAD), or extracorporeal membrane oxygenator (ECMO) applications. It is designed to operate without bearings, seals and valves, and without regions of blood stasis, friction, or wear. The PediVAS pump is compatible with the CentriMag hardware, although the priming volume was reduced from 31 to 14 ml, and the port size reduced from 3/8 to (1/4) in. For the expected range of pediatric flow (0.3-3.0 L/min), the PediVAS exhibited superior hydraulic efficiency compared with the CentriMag. The PediVAS was evaluated in 14 pediatric animals for up to 30 days, demonstrating acceptable hydraulic function and hemocompatibility. The current results substantiate the performance and biocompatibility of the PediVAS cardiac assist system and are likely to support initiation of a US clinical trial in the future.

  10. Assessment of Hydraulic Performance and Biocompatibility of a MagLev Centrifugal Pump System Designed for Pediatric Cardiac or Cardiopulmonary Support

    PubMed Central

    Dasse, Kurt A.; Gellman, Barry; Kameneva, Marina V.; Woolley, Joshua R.; Johnson, Carl A.; Gempp, Thomas; Marks, John D.; Kent, Stella; Koert, Andrew; Richardson, J. Scott; Franklin, Steve; Snyder, Trevor A.; Wearden, Peter; Wagner, William R.; Gilbert, Richard J.; Borovetz, Harvey S.

    2011-01-01

    The treatment of children with life-threatening cardiac and cardiopulmonary failure is a large and underappreciated public health concern. We have previously shown that the CentriMag is a magnetically levitated centrifugal pump system, having the utility for treating adults and large children (1,500 utilized worldwide). We present here the Pedi-VAS, a pump system whose design was modified from the CentriMag to meet the physiological requirements of young pediatric and neonatal patients. The PediVAS is comprised of a single-use centrifugal blood pump, reusable motor, and console, and is suitable for right ventricular assist device (RVAD), left ventricular assist device (LVAD), biventricular assist device (BVAD), or extracorporeal membrane oxygenator (ECMO) applications. It is designed to operate without bearings, seals and valves, and without regions of blood stasis, friction, or wear. The PediVAS pump is compatible with the CentriMag hardware, although the priming volume was reduced from 31 to 14 ml, and the port size reduced from 3/8 to ¼ in. For the expected range of pediatric flow (0.33.0 L/min), the PediVAS exhibited superior hydraulic efficiency compared with the CentriMag. The PediVAS was evaluated in 14 pediatric animals for up to 30 days, demonstrating acceptable hydraulic function and hemocompatibility. The current results substantiate the performance and biocompatibility of the PediVAS cardiac assist system and are likely to support initiation of a US clinical trial in the future. PMID:18043164

  11. Next Generation HeliMag UXO Mapping Technology

    DTIC Science & Technology

    2010-01-01

    Ancillary instrumentation records aircraft height above ground and attitude. A fluxgate magnetometer is used to allow for aeromagnetic compensation of... Magnetometer System WWII World War II WAA wide area assessment ACKNOWLEDGEMENTS This Next Generation HeliMag Unexploded Ordnance (UXO) Mapping...for deployment of seven total-field magnetometers on a Kevlar reinforced boom mounted on a Bell 206L helicopter. The objectives of this

  12. Thermal Expansion Behavior in TcO2. Toward Breaking the Tc-Tc Bond.

    PubMed

    Reynolds, Emily; Zhang, Zhaoming; Avdeev, Maxim; Thorogood, Gordon J; Poineau, Frederic; Czerwinski, Kenneth R; Kimpton, Justin A; Kennedy, Brendan J

    2017-08-07

    The structure of TcO 2 between 25 and 1000 °C has been determined in situ using X-ray powder diffraction methods and is found to remain monoclinic in space group P2 1 /c. Thermal expansion in TcO 2 is highly anisotropic, with negative thermal expansion of the b axis observed above 700 °C. This is the result of an anomalous expansion along the a axis that is a consequence of weakening of the Tc-Tc bonds.

  13. Clinical significance of TC21 overexpression in oral cancer.

    PubMed

    Macha, Muzafar A; Matta, Ajay; Sriram, Uma; Thakkar, Alok; Shukla, N K; Datta Gupta, Siddhartha; Ralhan, Ranju

    2010-07-01

    In search of novel molecular markers for oral cancer, we reported increased levels of TC21/R-Ras2 transcripts in oral squamous cell carcinoma by differential display. The aim of this study was to determine the clinical significance of TC21 in oral cancer. Immunohistochemical analysis of TC21 protein expression was carried out in 120 leukoplakias, 83 OSCCs and 30 non-malignant tissues, confirmed by immunoblotting, and correlated with clinicopathological parameters as well as disease prognosis. Co-immunoprecipitation assays were carried out to identify the interaction partners of TC21 protein in oral cancer cells and tissues. TC21 nuclear expression increased from normal oral tissues to leukoplakia and frank malignancy (P < 0.001). TC21 overexpression was observed in 74.2% leukoplakia with no dysplasia, 75.9% dysplasias and 79.5% OSCCs in comparison with normal oral tissues. Receiver operating characteristic analysis showed that the area-under-the curve values were 0.895, 0.885, and 0.919, while the positive predictive values were 95.8%, 95.6%, and 97.1%, for nuclear immunostaining for normal versus leukoplakia with no dysplasia, leukoplakic lesions with dysplasia, and OSCCs, respectively. Immunoblotting confirmed overexpression of TC21 in oral lesions. Using co-immunoprecipitation assays, we showed interactions of TC21 with Erk2, PI3-K, 14-3-3zeta and 14-3-3sigma proteins in oral cancer cells. Our findings suggested that alteration in TC21 expression is an early event in oral cancer and correlates with poor prognosis of OSCCs. TC21 interactions with Erk2, PI3-K, 14-3-3zeta and 14-3-3sigma proteins in oral cancer cells and tissues suggests the involvement of TC21 in signaling pathways in oral cancer.

  14. Discovery of radioactive silver ((110m)Ag) in spiders and other fauna in the terrestrial environment after the meltdown of Fukushima Dai-ichi nuclear power plant.

    PubMed

    Nakanishi, Hiromi; Mori, Atsushi; Takeda, Kouki; Tanaka, Houdo; Kobayashi, Natsuko; Tanoi, Keitaro; Yamakawa, Takashi; Mori, Satoshi

    2015-01-01

    Six months after the explosion of TEPCO's Fukushima Dai-ichi nuclear power plant, radioactive silver ((110m)Ag), was detected in concentrations of 3754 Bq/kg in Nephila clavata (the orb-web spider; Joro-gumo in Japanese) collected at Nimaibashi, Iitate village in Fukushima Prefecture, whereas (110m)Ag in the soil was 43.1 Bq/kg. A survey of 35 faunal species in the terrestrial environment during the 3.5 years after the accident showed that most of Anthropoda had two orders higher (110m)Ag in their tissues than soils, although silver is not an essential element for their life. However, tracing of the activity of (110m)Ag detected in spider Atypus karschi collected regularly at a fixed location showed that it declined much faster than the physical half-life. These results suggest that (110m)Ag was at once biologically concentrated by faunal species, especially Arthropoda, through food chain. The factors affecting the subsequent rapid decline of (110m)Ag concentration in faunal species are discussed.

  15. Discovery of radioactive silver (110mAg) in spiders and other fauna in the terrestrial environment after the meltdown of Fukushima Dai-ichi nuclear power plant

    PubMed Central

    NAKANISHI, Hiromi; MORI, Atsushi; TAKEDA, Kouki; TANAKA, Houdo; KOBAYASHI, Natsuko; TANOI, Keitaro; YAMAKAWA, Takashi; MORI, Satoshi

    2015-01-01

    Six months after the explosion of TEPCO’s Fukushima Dai-ichi nuclear power plant, radioactive silver (110mAg), was detected in concentrations of 3754 Bq/kg in Nephila clavata (the orb-web spider; Joro-gumo in Japanese) collected at Nimaibashi, Iitate village in Fukushima Prefecture, whereas 110mAg in the soil was 43.1 Bq/kg. A survey of 35 faunal species in the terrestrial environment during the 3.5 years after the accident showed that most of Anthropoda had two orders higher 110mAg in their tissues than soils, although silver is not an essential element for their life. However, tracing of the activity of 110mAg detected in spider Atypus karschi collected regularly at a fixed location showed that it declined much faster than the physical half-life. These results suggest that 110mAg was at once biologically concentrated by faunal species, especially Arthropoda, through food chain. The factors affecting the subsequent rapid decline of 110mAg concentration in faunal species are discussed. PMID:25864469

  16. Development of Tc(IV)-Incorporated Fe Minerals to Enhance 99Tc Retention in Glass Waste Form

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Um, Wooyong; Luksic, Steven A.; Wang, Guohui

    Iron minerals have been considered to be good hosts for Tc immobilization because the Tc(IV) ion substitutes for Fe(III) in the crystal structure of the Fe oxide due to similarities in (1) cation size [Tc(IV) = 78.5 pm ; Fe(III) = 69 or 78.5 pm], (2) metal-oxygen interatomic distance (Tc—O = 0.199 nm, Fe—O = 0.203 nm), (3) number of coordinating oxygen atoms (both 6-fold coordinated), and (4) the redox potential (Eh=ca. +20 mV at pH = 7) for a redox couple between Tc(VII)/Tc(IV) and Fe(III)/Fe(II). Magnetite, maghemite, and trevorite are iron oxide minerals and all belong to spinel mineralmore » group. Laboratory testing shows that Tc can be removed from aqueous waste solutions by a process of Tc reduction from Tc(VII) to Tc(IV) followed by co-precipitation with iron oxide minerals during recrystallization of Fe(OH)2(s) used as an initial solid precursor. X-ray absorption near edge structure (XANES) spectroscopy confirmed that Tc was in the +4 oxidation state in final Tc-Fe minerals. The Tc-incorporated Fe minerals were also tested for Tc retention in glass melts at different temperatures between 600 – 1,000 oC in a furnace. After being cooled in air, the solid glass specimens collected at different temperatures were analyzed for Tc oxidation state using XANES and Tc retention using liquid scintillation counting (LSC). Even though Tc(IV) started to reoxidize at 600 oC, Tc retention in the final glass specimen prepared with Tc-incorporated Fe mineral even at high temperatures was at least two times higher than glass prepared with KTcO4 salt. Higher Tc retention in glass is considered to result from limited and delayed Tc volatilization process due to Fe mineral encapsulation for Tc. Therefore, the results showing the presence of Tc(IV) in the Fe mineral structure indicate strong possibility to enhance Tc retention in borosilicate glass as well as to reduce the remediation costs at the Hanford Site.« less

  17. Interaction of both plasmas in CO2 laser-MAG hybrid welding of carbon steel

    NASA Astrophysics Data System (ADS)

    Kutsuna, Muneharu; Chen, Liang

    2003-03-01

    Researches and developments of laser and arc hybrid welding has been curried out since in 1978. Especially, CO2 laser and TIG hybrid welding has been studied for increasing the penetration depth and welding speed. Recently laser and MIG/MAG/Plasma hybrid welding processes have been developed and applied to industries. It was recognized as a new welding process that promote the flexibility of the process for increasing the penetration depth, welding speed and allowable joint gap and improving the quality of the welds. In the present work, CO2 Laser-MAG hybrid welding of carbon steel (SM490) was investigated to make clear the phenomenon and characteristics of hybrid welding process comparing with laser welding and MAG process. The effects of many process parameters such as welding current, arc voltage, welding speed, defocusing distance, laser-to-arc distance on penetration depth, bead shape, spatter, arc stability and plasma formation were investigated in the present work. Especially, the interaction of laser plasma and MAG arc plasma was considered by changing the laser to arc distance (=DLA).

  18. Inverse correlation between quasiparticle mass and Tc in a cuprate high-Tc superconductor

    PubMed Central

    Putzke, Carsten; Malone, Liam; Badoux, Sven; Vignolle, Baptiste; Vignolles, David; Tabis, Wojciech; Walmsley, Philip; Bird, Matthew; Hussey, Nigel E.; Proust, Cyril; Carrington, Antony

    2016-01-01

    Close to a zero-temperature transition between ordered and disordered electronic phases, quantum fluctuations can lead to a strong enhancement of electron mass and to the emergence of competing phases such as superconductivity. A correlation between the existence of such a quantum phase transition and superconductivity is quite well established in some heavy fermion and iron-based superconductors, and there have been suggestions that high-temperature superconductivity in copper-oxide materials (cuprates) may also be driven by the same mechanism. Close to optimal doping, where the superconducting transition temperature Tc is maximal in cuprates, two different phases are known to compete with superconductivity: a poorly understood pseudogap phase and a charge-ordered phase. Recent experiments have shown a strong increase in quasiparticle mass m* in the cuprate YBa2Cu3O7-δ as optimal doping is approached, suggesting that quantum fluctuations of the charge-ordered phase may be responsible for the high-Tc superconductivity. We have tested the robustness of this correlation between m* and Tc by performing quantum oscillation studies on the stoichiometric compound YBa2Cu4O8 under hydrostatic pressure. In contrast to the results for YBa2Cu3O7-δ, we find that in YBa2Cu4O8, the mass decreases as Tc increases under pressure. This inverse correlation between m* and Tc suggests that quantum fluctuations of the charge order enhance m* but do not enhance Tc. PMID:27034989

  19. TetraMag: A compact magnetizing device based on eight rotating permanent magnets

    NASA Astrophysics Data System (ADS)

    Gilbert, M.; Mertins, H.-Ch.; Tesch, M.; Berges, O.; Feilbach, Herbert; Schneider, C. M.

    2012-02-01

    In this paper we describe a novel magnetizing device based on eight rotatable permanent magnets arranged in a quadrupolar configuration, which is termed the TetraMag. TetraMag creates stable and homogeneous magnetic fields at the sample position with a resolution of 0.02 mT tunable between -570 mT and +570 mT. The field direction is continuously rotatable between 0° and 360° within the sample plane, while the field strength is maintained. A simplified mathematical description of TetraMag is developed leading to magnetic field calculations which are in good agreement with the experimental results. This versatile device avoids electrical energy dissipation, cooling mechanisms, and hysteresis effects known from classical electromagnets. It is ultrahigh vacuum compatible and it offers a completely free optical path over 180° for magneto-optical experiments. It is suitable for scattering experiments with synchrotron radiation and neutrons and may be employed in a large class of magnetization experiments.

  20. Metal-metal bonding and aromaticity in [M2(NHCHNH)3]2 (μ-E)2 (E = O, S; M = Nb, Mo, Tc, Ru, Rh).

    PubMed

    Yan, Xiuli; Meng, Lingpeng; Sun, Zheng; Li, Xiaoyan

    2016-02-01

    The nature of M-M bonding and aromaticity of [M2(NHCHNH)3]2(μ-E)2 (E = O, S; M = Nb, Mo, Tc, Ru, Rh) was investigated using atoms in molecules (AIM) theory, electron localization function (ELF), natural bond orbital (NBO) and molecular orbital analysis. These analyses led to the following main conclusions: in [M2(NHCHNH)3]2(μ-E)2 (E = O, S; M = Nb, Mo, Tc, Ru, Rh), the Nb-Nb, Ru-Ru, and Rh-Rh bonds belong to "metallic" bonds, whereas Mo-Mo and Tc-Tc drifted toward the "dative" side; all these bonds are partially covalent in character. The Nb-Nb, Mo-Mo, and Tc-Tc bonds are stronger than Ru-Ru and Rh-Rh bonds. The M-M bonds in [M2(NHCHNH)3]2(μ-S)2 are stronger than those in [M2(NHCHNH)3]2(μ-O)2 for M = Nb, Mo, Tc, and Ru. The NICS(1)ZZ values show that all of the studied molecules, except [Ru2(NHCHNH)3]2(μ-O)2, are aromaticity molecules. O-bridged compounds have more aromaticity than S-bridged compounds. Graphical Abstract Left Molecular graph, and right electron localization function (ELF) isosurface of [M2(NHCHNH)3]2(μ-E)2(E = O, S; M = Nb, Mo, Tc, Ru, Rh).

  1. Neurotensin receptor-2 and -3 are crucial for the anti-apoptotic effect of neurotensin on pancreatic beta-TC3 cells.

    PubMed

    Béraud-Dufour, Sophie; Coppola, Thierry; Massa, Fabienne; Mazella, Jean

    2009-12-01

    The neuropeptide neurotensin (NT) has been recently shown to protect pancreatic beta cells from toxic agents-induced apoptosis through interaction with the NT receptor-2 (NTSR2) and activation of the phosphatidylinositol-3 kinase pathway. However, expression of the NT receptor-3/sortilin (NTSR3) in the mouse pancreatic beta cell line -TC3 led us to investigate its possible functional role in these cells. By using siRNA, immunoprecipitation, co-localization and caspase-3 assays,we provide evidence for a functional endogenous interaction between NTSR2 and NTSR3. Expression of both receptors is necessary for the protective action of NT on staurosporine-induced caspase-3 activity in -TC3 cells. Moreover, NTSR2 and NTSR3 co-immunoprecipitate and are co-localized at the plasma membrane. Thus, the NT response in beta cells is controlled by the formation of a functional complex between NTSR2 and NTSR3.

  2. Investigating the laser heating of underdense plasmas at conditions relevant to MagLIF

    NASA Astrophysics Data System (ADS)

    Harvey-Thompson, Adam

    2015-11-01

    The magnetized Liner Inertial Fusion (MagLIF) scheme has achieved thermonuclear fusion yields on Sandia's Z Facility by imploding a cylindrical liner filled with D2 fuel that is preheated with a multi-kJ laser and pre-magnetized with an axial field Bz = 10 T. The challenge of fuel preheating in MagLIF is to deposit several kJ's of energy into an underdense (ne/ncrit<0.1) fusion fuel over ~ 10 mm target length efficiently and without introducing contaminants that could contribute to unacceptable radiative losses during the implosion. Very little experimental work has previously been done to investigate laser heating of gas at densities, scale lengths, modest intensities (Iλ2 ~ 1014 watts- μm2 /cm2) and magnetization parameters (ωceτe ~ 10) necessary for MagLIF. In particular, magnetization of the preheated plasma suppresses electron thermal conduction, which can modify laser energy coupling. Providing an experimental dataset in this regime is essential to not only understand the dynamics of a MagLIF implosion and stagnation, but also to validate magnetized transport models and better understand the physics of laser propagation in magnetized plasmas. In this talk, we present data and analysis of several experiments conducted at OMEGA-EP and at Z to investigate laser propagation and plasma heating in underdense D2 plasmas under a range of conditions, including densities (ne = 0.05-0.1 nc) and magnetization parmaters (ωceτe ~ 0-10). The results show differences in the electron temperature of the heated plasma and the velocity of the laser burn wave with and without an applied magnetic field. We will show comparisons of these experimental results to 2D and 3D HYDRA simulations, which show that the effect of the magnetic field on the electron thermal conduction needs to be taken into account when modeling laser preheat. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the National Nuclear Security Administration

  3. Theoretical Modeling of (99)Tc NMR Chemical Shifts.

    PubMed

    Hall, Gabriel B; Andersen, Amity; Washton, Nancy M; Chatterjee, Sayandev; Levitskaia, Tatiana G

    2016-09-06

    Technetium-99 (Tc) displays a rich chemistry due to its wide range of accessible oxidation states (from -I to +VII) and ability to form coordination compounds. Determination of Tc speciation in complex mixtures is a major challenge, and (99)Tc nuclear magnetic resonance (NMR) spectroscopy is widely used to probe chemical environments of Tc in odd oxidation states. However, interpretation of (99)Tc NMR data is hindered by the lack of reference compounds. Density functional theory (DFT) calculations can help to fill this gap, but to date few computational studies have focused on (99)Tc NMR of compounds and complexes. This work evaluates the effectiveness of both pure generalized gradient approximation and their corresponding hybrid functionals, both with and without the inclusion of scalar relativistic effects, to model the (99)Tc NMR spectra of Tc(I) carbonyl compounds. With the exception of BLYP, which performed exceptionally well overall, hybrid functionals with inclusion of scalar relativistic effects are found to be necessary to accurately calculate (99)Tc NMR spectra. The computational method developed was used to tentatively assign an experimentally observed (99)Tc NMR peak at -1204 ppm to fac-Tc(CO)3(OH)3(2-). This study examines the effectiveness of DFT computations for interpretation of the (99)Tc NMR spectra of Tc(I) coordination compounds in high salt alkaline solutions.

  4. Initial direct comparison of 99mTc-TOC and 99mTc-TATE in identifying sites of disease in patients with proven GEP NETs.

    PubMed

    Cwikla, Jaroslaw B; Mikolajczak, Renata; Pawlak, Dariusz; Buscombe, John R; Nasierowska-Guttmejer, Anna; Bator, Andrzej; Maecke, Helmut R; Walecki, Jerzy

    2008-07-01

    The imaging of neuroendocrine tumors has become one of the most significant areas in nuclear oncology. In an attempt to provide high-quality imaging and possible sensitivity at a reduced cost, time, and radiation dose, several (99m)Tc agents have been proposed. The aim of this initial study was to compare the tumor uptake and biodistribution of 2 new 6-hydrazinopyridine-3-carboxylic acid (HYNIC)-derivatized Tyr(3)-octreotide analogs, (99m)Tc-[HYNIC,Tyr(3)]octreotide ((99m)Tc-TOC) and (99m)Tc-[HYNIC,Tyr(3),Thr(8)]octreotide ((99m)Tc-TATE), in patients with somatostatin receptor-expressing tumors. Each of 12 patients with proven gastrointestinal pancreatic neuroendocrine tumors received a mean activity of 520 MBq of (99m)Tc-TOC and (99m)Tc-TATE. Scintigraphy with both tracers was performed 3-4 h after their injection using standard whole-body and SPECT imaging. The images were reviewed subjectively by 2 readers, who reported tumor uptake lesion by lesion. Both radiotracers demonstrated concordance between the results in 7 patients (58%). In total, 110 sites of disease were identified with (99m)Tc-TOC, compared with 115 with (99m)Tc-TATE. There was 1 case in which (99m)Tc-TOC identified sites of disease not seen on (99m)Tc-TATE imaging but 4 cases in which some sites of disease were seen with (99m)Tc-TATE and not (99m)Tc-TOC. In this initial study, both tracers seem to show similar sites of tumor, with (99m)Tc-TATE having a slight edge in the total number of lesions seen, especially in lymph node metastases.

  5. Two peptide receptor ligands (99m)Tc-EDDA/HYNIC-Tyr(3)-octreotide and (99m)Tc-EDDA/HYNIC-(D)Glu-octagastrin for scintigraphy of medullary thyroid carcinoma.

    PubMed

    Kosowicz, Jerzy; Mikołajczak, Renata; Czepczyński, Rafał; Ziemnicka, Katarzyna; Gryczyńska, Maria; Sowiński, Jerzy

    2007-10-01

    Somatostatin and gastrin receptors are overexpressed in medullary thyroid carcinoma (MTC) cells; hence, both of them are potential targets for peptide receptor scintigraphy and radiotherapy. Therefore, the aim of our study was to assess the clinical value of two technetium-99m-labeled peptides, a new gastrin analog, the EDDA/HYNIC-(D)Glu-octagastrin and a somatostatin analog, EDDA/HYNIC-Tyr(3)-octreotide (EDDA/HYNIC-TOC) for scintigraphy in patients with MTC to detect recurrences and metastases and select patients for peptide receptor radiotherapy. Thirty (30) patients, 20 females and 10 males, 22-83 years of age (mean, 52.7) with the diagnosis of MTC in different stages of the disease (preoperative, postsurgery, remission, recurrence, or metastatic disease) were included in this study. Before surgery, in all patients serum calcitonin concentrations were elevated. The diagnosis of MTC was confirmed in all cases by histopathology of the removed tumor and immunohistochemical staining giving positive reactions for calcitonin and chromogranin A. Imaging studies using (99m)Tc-EDDA/HYNIC-TOC and a new minigastrin analog, (99m)Tc-EDDA/HYNIC-(D)Glu-octagastrin, were performed in each patient and the results compared with each other and with other imaging methods. Scans of the whole body, head, neck, and chest were performed 2 and 4 hours after injections of the tracer, 500-600 MBq in each case, using a double-head Varicam (Elscint, Israel) gamma camera. (99m)Tc-EDDA/HYNIC-TOC detected somatostatin receptor-positive lesions in 20 patients with MTC, whereas (99m)Tc-EDDA/HYNIC-(D)Glu-octagastrin displayed gastrin receptors in 11 patients. In 9 cases, the scans were positive in both methods, although in 2 cases different pathologic foci were visualized. In 12 cases, only (99m)Tc-EDDA/HYNIC-TOC scintigraphy was positive, whereas in 3 other cases only (99m)Tc-EDDA/HYNIC-(D)Glu-octagastrin revealed pathologic lesions. Scintigraphy using (99m)Tc-HYNIC-TOC permits the visualization

  6. Evaluation of 99mTc-3PRGD2 integrin receptor imaging in hepatocellular carcinoma tumour-bearing mice: comparison with 18F-FDG metabolic imaging.

    PubMed

    Zheng, Jieling; Miao, Weibing; Huang, Chao; Lin, Haoxue

    2017-07-01

    Our study was designed to explore the utility of 99m Tc-HYNIC-PEG 4 -E[PEG 4 -c(RGDfK)] 2 ( 99m Tc-3PRGD 2 ) for the detection of hepatocellular carcinoma (HCC) and specifically to compare the diagnostic performance of 99m Tc-3PRGD 2 integrin receptor imaging and 2-18-fluoro-2-deoxy-D-glucose ( 18 F-FDG) metabolic imaging in a nude mouse model. 99m Tc-3PRGD 2 was synthesized using a HYNIC-3PRGD 2 lyophilized kit with 99m TcO 4 labelling. The nude mouse animal model was established by subcutaneously injecting 5 × 10 7 /ml HepG2 cells into the shoulder flank of each mouse. Biodistribution studies were performed at 0.5, 1, 2 and 4 h after intravenous administration of 0.37 MBq of 99m Tc-3PRGD 2 . Immunohistochemistry was performed to evaluate the expression level of integrin αvβ3 in the HCC tissues. Dynamic imaging was performed using list-mode after the administration of 55.5 MBq of 99m Tc-3PRGD 2 , to reconstruct the multiphase images and acquire the best initial scan time. At 8, 12, 16, 20 and 24 days after inoculation with HepG2 cells, 55.5 MBq of 99m Tc-3PRGD 2 and 37 MBq of 18 F-FDG were injected successively into the nude mouse model, subsequently, simultaneous SPECT/PET imaging was performed to calculate the tumour volume and tumour uptake of 99m Tc-3PRGD 2 and 18 F-FDG. The biodistribution study first validated that the tumour uptake of 99m Tc-3PRGD 2 at the different time points was higher than that of all the other organs tested in the experiment, except for the kidney. Integrin αvβ3 expressed highly in early stage HCC and declined for further necrosis of the tumour tissue. Subcutaneous tumours were visualized clearly with excellent contrast under 99m Tc-3PRGD 2 SPECT/CT imaging, and the multiphase imaging comparison showed the tumours were prominent at 0.5 h, suggesting that the best initial scan time is 0.5 h post-injection. The comparison of the imaging results of the two methods showed that 99m Tc-3PRGD 2 integrin receptor imaging was

  7. An effective 2-band eg model of sulfur hydride H3S for high-Tc superconductivity

    NASA Astrophysics Data System (ADS)

    Nishiguchi, Kazutaka; Teranishi, Shingo; Miyao, Satoaki; Matsushita, Goh; Kusakabe, Koichi

    To understand high transition temperature (Tc) superconductivity in sulfur hydride H3S, we propose an effective 2-band model having the eg symmetry as the minimal model for H3S. Two eg orbitals centered on a sulfur S atom are chosen for the smallest representation of relevant bands with the van-Hove singularity around the Fermi levels except for the Γ-centered small hole pockets by the sulfur 3 p orbitals. By using the maximally localized Wannier functions, we derive the minimal effective model preserving the body-centered cubic (bcc) crystal symmetry of the H3S phase having the highest Tc ( 203 K under pressures) among the other polymorphs of H3S.

  8. Indirect searches of Galactic diffuse dark matter in INO-MagICAL detector

    DOE PAGES

    Khatun, Amina; Laha, Ranjan; Agarwalla, Sanjib Kumar

    2017-06-12

    Here, the signatures for the existence of dark matter are revealed only through its gravitational interaction. Theoretical arguments support that the Weakly Interacting Massive Particle (WIMP) can be a class of dark matter and it can annihilate and/or decay to Standard Model particles, among which neutrino is a favorable candidate. We show that the proposed 50 kt Magnetized Iron CALorimeter (MagICAL) detector under the India-based Neutrino Observatory (INO) project can play an important role in the indirect searches of Galactic diffuse dark matter in the neutrino and antineutrino mode separately. We present the sensitivity of 500 kt·yr MagICAL detector to set limits on the velocity-averaged self-annihilation cross-section (more » $$\\langle$$σv$$\\rangle$$) and decay lifetime (τ) of dark matter having mass in the range of 2 GeV ≤ m χ ≤ 90 GeV and 4 GeV ≤ m χ ≤ 180 GeV respectively, assuming no excess over the conventional atmospheric neutrino and antineutrino fluxes at the INO site. Our limits for low mass dark matter constrain the parameter space which has not been explored before. We show that MagICAL will be able to set competitive constraints, $$\\langle$$σv$$\\rangle$$ ≤ 1.87 × 10 -24 cm 3 s -1 for χχ→$$ν\\overline{v}$$ χχ→$$ν\\overline{v}$$ and τ ≥ 4.8 × 10 24s for χ → $$ν\\overline{v}$$ χ → $$ν\\overline{v}$$ at 90% C.L. (1 d.o.f.) for m χ = 10 GeV assuming the NFW as dark matter density profile.« less

  9. Indirect searches of Galactic diffuse dark matter in INO-MagICAL detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khatun, Amina; Laha, Ranjan; Agarwalla, Sanjib Kumar

    Here, the signatures for the existence of dark matter are revealed only through its gravitational interaction. Theoretical arguments support that the Weakly Interacting Massive Particle (WIMP) can be a class of dark matter and it can annihilate and/or decay to Standard Model particles, among which neutrino is a favorable candidate. We show that the proposed 50 kt Magnetized Iron CALorimeter (MagICAL) detector under the India-based Neutrino Observatory (INO) project can play an important role in the indirect searches of Galactic diffuse dark matter in the neutrino and antineutrino mode separately. We present the sensitivity of 500 kt·yr MagICAL detector to set limits on the velocity-averaged self-annihilation cross-section (more » $$\\langle$$σv$$\\rangle$$) and decay lifetime (τ) of dark matter having mass in the range of 2 GeV ≤ m χ ≤ 90 GeV and 4 GeV ≤ m χ ≤ 180 GeV respectively, assuming no excess over the conventional atmospheric neutrino and antineutrino fluxes at the INO site. Our limits for low mass dark matter constrain the parameter space which has not been explored before. We show that MagICAL will be able to set competitive constraints, $$\\langle$$σv$$\\rangle$$ ≤ 1.87 × 10 -24 cm 3 s -1 for χχ→$$ν\\overline{v}$$ χχ→$$ν\\overline{v}$$ and τ ≥ 4.8 × 10 24s for χ → $$ν\\overline{v}$$ χ → $$ν\\overline{v}$$ at 90% C.L. (1 d.o.f.) for m χ = 10 GeV assuming the NFW as dark matter density profile.« less

  10. In vivo imaging of tumour angiogenesis in mice with the alpha(v)beta (3) integrin-targeted tracer 99mTc-RAFT-RGD.

    PubMed

    Sancey, Lucie; Ardisson, Valérie; Riou, Laurent M; Ahmadi, Mitra; Marti-Batlle, Danièle; Boturyn, Didier; Dumy, Pascal; Fagret, Daniel; Ghezzi, Catherine; Vuillez, Jean-Philippe

    2007-12-01

    The molecular imaging of tumour neoangiogenesis currently represents a major field of research for the diagnostic and treatment strategy of solid tumours. Endothelial cells from tumour neovessels overexpress the alpha(v)beta(3) integrin, which selectively binds to Arg-Gly-Asp (RGD)-containing peptides. We evaluated the potential of the novel radiotracer (99m)Tc-RAFT-RGD for the non-invasive molecular imaging of alpha(v)beta(3) integrin expression in mice models of tumour development. (99m)Tc-RAFT-RGD, (99m)Tc-cRGD (specific control) and (99m)Tc-RAFT-RAD (non-specific control) were injected intravenously to mice bearing B16F0 or TS/A-pc tumours. In vivo whole-body tomographic imaging and post-mortem biodistribution studies were performed 60 min following tracer injection. Adjacent tumour slices were used to compare the localisation of neovessels from immunostaining and the pattern of (99m)Tc-RAFT-RGD uptake from autoradiographic ex vivo imaging. Biodistribution studies indicated that (99m)Tc-RAFT-RGD tumour uptake was significantly higher than that of (99m)Tc-RAFT-RAD in B16F0 (2.4+/-0.5 vs 1.0+/-0.1%ID/g, respectively) and in TS/A-pc tumours (2.7+/-0.8 vs 0.7+/-0.1%ID/g, respectively). Immunohistochemical and autoradiographic studies indicated that (99m)Tc-RAFT-RGD intratumoural uptake preferentially occurred in angiogenic areas. Tomographic imaging allowed tumour visualisation following injection of (99m)Tc-RAFT-RGD and (99m)Tc-cRGD with similar tumour-to-contralateral muscle (T/CM) ratios in B16F0 and in TS/A-pc tumours whereas (99m)Tc-RAFT-RAD T/CM ratios did not allow tumour imaging. In accordance with the higher level of alpha(v)beta(3) integrin expression on TS/A-pc tumours than on B16F0 tumours as determined from western blot and immunoprecipitation analyses, the (99m)Tc-RAFT-RGD T/CM ratio was significantly higher in TS/A-pc than in B16F0 tumours. (99m)Tc-RAFT-RGD allowed the in vivo imaging of alpha(v)beta(3) integrin tumour expression.

  11. Use of Tc-99m-galactosyl-neoglycoalbumin (Tc-NGA) to determine hepatic blood flow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stadalnik, R.C.; Vera, D.R.; Woodle, E.S.

    1984-01-01

    Tc-NGA is a new liver radiopharmaceutical which binds to a hepatocyte-specific membrane receptor. Three characteristics of Tc-NGA can be exploited in the measurement of hepatic blood flow (HBF): 1) ability to alter the affinity of Tc-NGA for its receptor by changing the galactose: albumin ratio; 2) ability to achieve a high specific activity with Tc-99m labeling; and 3) ability to administer a high molar dose of Tc-NGA without physiologic side effects. In addition, kinetic modeling of Tc-NGA dynamic data can provide estimates of hepatic receptor concentration. In experimental studies in young pigs, HBF was determined using two techniques: 1) kineticmore » modeling of dynamic data using moderate affinity, low specific activity Tc-NGA (Group A, n=12); and 2) clearance (CL) technique using high affinity, high specific activity Tc-NGA (Group B, n=4). In both groups, HBF was determined simultaneously by continuous infusion of indocyanine green (CI-ICG) with hepatic vein sampling. Regression analysis of HBF measurements obtained with the Tc-NGA kinetic modeling technique and the CI-ICG technique (Group A) revealed good correlation between the two techniques (r=0.802, p=0.02). Similarly, HBF determination by the clearance technique (Group B) provided highly accurate measurements when compared to the CI-ICG technique. Hepatic blood flow measurements by the clearance technique (CL-NGA) fell within one standard deviation of the error associated with each CI-ICG HBF measurement (all CI-ICG standard deviations were less than 10%).« less

  12. Trypanosoma cruzi diversity in the Gran Chaco: mixed infections and differential host distribution of TcV and TcVI.

    PubMed

    Monje-Rumi, María M; Brandán, Cecilia Pérez; Ragone, Paula G; Tomasini, Nicolás; Lauthier, Juan J; Alberti D'Amato, Anahí M; Cimino, Rubén O; Orellana, Viviana; Basombrío, Miguel A; Diosque, Patricio

    2015-01-01

    The transmission cycles of Trypanosoma cruzi in the Gran Chaco are complex networks involving domestic and wild components, whose interrelationships are not well understood. Knowing the circuit of transmission of the different Discrete Typing Units (DTUs) of T. cruzi in the complex environment of the Chaco region is relevant to understanding how the different components (reservoirs, vectors, ecotopes) interact. In the present study we identified the DTUs infecting humans and dogs in two rural areas of the Gran Chaco in Argentina, using molecular methods which avoid parasite culture. Blood samples of humans and dogs were typified by PCR-DNA blotting and hybridization assays with five specific DNA probes (TcI, TcII, TcIII, TcV and TcVI). PCR analyses were performed on seropositive human and dog samples and showed the presence of T. cruzi DNA in 41.7% (98/235) and 53% (35/66) samples, respectively. The identification of infective DTUs was determined in 83.6% (82/98) and 91.4% (32/35) in human and dog samples, respectively. Single infections (36.7% - 36/98) and a previously not detected high proportion of mixed infections (47.9% - 47/98) were found. In a 15.3% (15/98) of samples the infecting DTU was not identified. Among the single infections TcV was the most prevalent DTU (30.6% - 30/98) in human samples; while TcVI (42.8% - 15/35) showed the highest prevalence in dog samples. TcV/TcVI was the most prevalent mixed infection in humans (32.6% - 32/98); and TcI/TcVI (14.3% - 5/35) in dogs. Significant associations between TcV with humans and TcVI with dogs were detected. For the first time, the presence of TcIII was detected in humans from this region. The occurrence of one human infected whit TcIII (a principally wild DTU) could be suggested the emergence of this, in domestic cycles in the Gran Chaco. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Oxygen content and Tc of Ba 0.6K 0.4BiO 3

    NASA Astrophysics Data System (ADS)

    Idemoto, Yasushi; Iwata, Yoshiki; Fueki, Kazuo

    1992-10-01

    The single phase of Ba 1- xK xBiO 3-δ with x=0.316∼0.514 was prepared by adding an excess amount of KO 2 to the starting materials and by washing the products with ethanol. In the case of Ba 0.6K 0.4BiO 3-δ, superconductivity appeared when the bismuth valence was higher than +4.2 and the highest Tc was attained at around a bismuth valence of +4.3. Tc decreased with the increase in bismuth valence above +4.3. A high temperature X-ray diffraction study revealed that the lattice constant increases by the thermal expansion below 400°C but the increase becomes remarkable above 400°C owing to evaporation of potassium and deoxygenation.

  14. Mental Health and the TC. Chapter 5.

    ERIC Educational Resources Information Center

    Acampora, Alfonso P., Ed.; Nebelkopf, Ethan, Ed.

    This document contains 19 papers from the ninth World Conference of Therapeutic Communities (TCs) that deal with the interface between the mental health establishments and the TC. Papers include: (1) "Psychiatry and the TC" (Jerome Jaffe); (2) "The Chemical Brain" (Sidney Cohen); (3) "Where Does the TC Fail?" (Ab…

  15. In-house cyclotron production of high-purity Tc-99m and Tc-99m radiopharmaceuticals.

    PubMed

    Martini, Petra; Boschi, Alessandra; Cicoria, Gianfranco; Zagni, Federico; Corazza, Andrea; Uccelli, Licia; Pasquali, Micòl; Pupillo, Gaia; Marengo, Mario; Loriggiola, Massimo; Skliarova, Hanna; Mou, Liliana; Cisternino, Sara; Carturan, Sara; Melendez-Alafort, Laura; Uzunov, Nikolay M; Bello, Michele; Alvarez, Carlos Rossi; Esposito, Juan; Duatti, Adriano

    2018-05-30

    In the last years, the technology for producing the important medical radionuclide technetium-99m by cyclotrons has become sufficiently mature to justify its introduction as an alternative source of the starting precursor [ 99m Tc][TcO 4 ] - ubiquitously employed for the production of 99m Tc-radiopharmaceuticals in hospitals. These technologies make use almost exclusively of the nuclear reaction 100 Mo(p,2n) 99m Tc that allows direct production of Tc-99m. In this study, it is conjectured that this alternative production route will not replace the current supply chain based on the distribution of 99 Mo/ 99m Tc generators, but could become a convenient emergency source of Tc-99m only for in-house hospitals equipped with a conventional, low-energy, medical cyclotron. On this ground, an outline of the essential steps that should be implemented for setting up a hospital radiopharmacy aimed at the occasional production of Tc-99m by a small cyclotron is discussed. These include (1) target production, (2) irradiation conditions, (3) separation/purification procedures, (4) terminal sterilization, (5) quality control, and (6) Mo-100 recovery. To address these issues, a comprehensive technology for cyclotron-production of Tc-99m, developed at the Legnaro National Laboratories of the Italian National Institute of Nuclear Physics (LNL-INFN), will be used as a reference example. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Tunicate cytostatic factor TC14-3 induces a polycomb group gene and histone modification through Ca2+ binding and protein dimerization

    PubMed Central

    2012-01-01

    Background As many invertebrate species have multipotent cells that undergo cell growth and differentiation during regeneration and budding, many unique and interesting homeostatic factors are expected to exist in those animals. However, our understanding of such factors and global mechanisms remains very poor. Single zooids of the tunicate, Polyandrocarpa misakiensis, can give off as many as 40 buds during the life span. Bud development proceeds by means of transdifferentiation of very limited number of cells and tissues. TC14-3 is one of several different but closely related polypeptides isolated from P. misakiensis. It acts as a cytostatic factor that regulates proliferation, adhesion, and differentiation of multipotent cells, although the molecular mechanism remains uncertain. The Polycomb group (PcG) genes are involved in epigenetic control of genomic activity in mammals. In invertebrates except Drosophila, PcG and histone methylation have not been studied so extensively, and genome-wide gene regulation is poorly understood. Results When Phe65 of TC14-3 was mutated to an acidic amino acid, the resultant mutant protein failed to dimerize. The replacement of Thr69 with Arg69 made dimers unstable. When Glu106 was changed to Gly106, the resultant mutant protein completely lost Ca2+ binding. All these mutant proteins lacked cytostatic activity, indicating the requirement of protein dimerization and calcium for the activity. Polyandrocarpa Eed, a component of PcG, is highly expressed during budding, like TC14-3. When wild-type and mutant TC14-3s were applied in vivo and in vitro to Polyandrocarpa cells, only wild-type TC14-3 could induce Eed without affecting histone methyltransferase gene expression. Eed-expressing cells underwent trimethylation of histone H3 lysine27. PmEed knockdown by RNA interference rescued cultured cells from the growth-inhibitory effects of TC14-3. Conclusion These results show that in P. misakiensis, the cytostatic activity of TC14-3 is

  17. High Tc screen-printed YBa2Cu3O(7-x) films - Effect of the substrate material

    NASA Astrophysics Data System (ADS)

    Bansal, Narottam P.; Simons, Rainee N.; Farrell, D. E.

    1988-08-01

    Thick films of YBa2Cu3O(7-x) have been deposited on highly polished alumina, magnesia spinel, nickel aluminum titanate (Ni-Al-Ti), and barium tetratitanate (Ba-Ti) substrates by the screen printing technique. Properties of the films were found to be highly sensitive to the choice of the substrate material. The film on Ba-Ti turned green after firing, due to a reaction with the substrate and were insulating. A film on Ni-Al-Ti had a Tc (onset) of about 95 K and lost 90 percent of its resistance by about 75 K. However, even at 4 K it was not fully superconducting, possibly due to a reaction between the film and the substrate and interdiffusion of the reaction products. The film on alumina had Tc (onset) of about 96 K, Tc (zero) of about 66 K, and Delta Tc of about 10 K. The best film was obtained on spinel and had Tc (onset) of about 94 K, zero resistance at 81 K, and a transition width of about 7 K.

  18. High Tc screen-printed YBa2Cu3O(7-x) films - Effect of the substrate material

    NASA Technical Reports Server (NTRS)

    Bansal, Narottam P.; Simons, Rainee N.; Farrell, D. E.

    1988-01-01

    Thick films of YBa2Cu3O(7-x) have been deposited on highly polished alumina, magnesia spinel, nickel aluminum titanate (Ni-Al-Ti), and barium tetratitanate (Ba-Ti) substrates by the screen printing technique. Properties of the films were found to be highly sensitive to the choice of the substrate material. The film on Ba-Ti turned green after firing, due to a reaction with the substrate and were insulating. A film on Ni-Al-Ti had a Tc (onset) of about 95 K and lost 90 percent of its resistance by about 75 K. However, even at 4 K it was not fully superconducting, possibly due to a reaction between the film and the substrate and interdiffusion of the reaction products. The film on alumina had Tc (onset) of about 96 K, Tc (zero) of about 66 K, and Delta Tc of about 10 K. The best film was obtained on spinel and had Tc (onset) of about 94 K, zero resistance at 81 K, and a transition width of about 7 K.

  19. The CentriMag: a new optimized centrifugal blood pump with levitating impeller.

    PubMed

    Mueller, Juerg Peter; Kuenzli, Andreas; Reuthebuch, Oliver; Dasse, Kurt; Kent, Stella; Zuend, Gregor; Turina, Marko Ivan; Lachat, Mario Louis

    2004-01-01

    Blood pumps are routinely used for circulatory and pulmonary support. However, blood trauma and pump failure remain severe drawbacks of currently available pump models. This study evaluated the first clinical application of a new, totally bearingless centrifugal blood pump (CentriMag). A centrifugal pump consisting of an electromagnetic suspended impeller was used as a blood pump during beating-heart coronary artery bypass grafting in 11 patients (mean weight, 77.4 kg). Heparin in a bolus of 150 IU/kg body weight was administered, and activated clotting time was maintained at approximately 180 to 250 seconds during extracorporeal circulation. Pump-induced blood trauma was evaluated by measurement of plasma free hemoglobin (PFH), lactate dehydrogenase (LDH), hematocrit, total bilirubin, and platelet levels. Mean pump flow was 3.3 +/- 0.62 L/min, and mean pressure gradient through the oxygenator was 69 +/- 4 mm Hg. No pump dysfunction occurred during a mean application time of 105 +/- 26 minutes. Inspection of the pump housings showed no internal thrombus formation despite low-dose heparinization. Only slight hemolysis was observed with a mean PFH level of 1.96 micromol/L; LDH, 460 U/L; hematocrit, 33%; total bilirubin, 25 micromol/L; and platelets, 191 x 10(3)/microL. The bearingless CentriMag blood pump is a safe and reliable new device that produces only minimal hemolysis. It seems to be suited for long-term evaluation as a blood pump for extracorporeal membrane oxygenation or as ventricular assist device.

  20. Interdisciplinary Collaboration amongst Colleagues and between Initiatives with the Magnetics Information Consortium (MagIC) Database

    NASA Astrophysics Data System (ADS)

    Minnett, R.; Koppers, A. A. P.; Jarboe, N.; Tauxe, L.; Constable, C.; Jonestrask, L.; Shaar, R.

    2014-12-01

    Earth science grand challenges often require interdisciplinary and geographically distributed scientific collaboration to make significant progress. However, this organic collaboration between researchers, educators, and students only flourishes with the reduction or elimination of technological barriers. The Magnetics Information Consortium (http://earthref.org/MagIC/) is a grass-roots cyberinfrastructure effort envisioned by the geo-, paleo-, and rock magnetic scientific community to archive their wealth of peer-reviewed raw data and interpretations from studies on natural and synthetic samples. MagIC is dedicated to facilitating scientific progress towards several highly multidisciplinary grand challenges and the MagIC Database team is currently beta testing a new MagIC Search Interface and API designed to be flexible enough for the incorporation of large heterogeneous datasets and for horizontal scalability to tens of millions of records and hundreds of requests per second. In an effort to reduce the barriers to effective collaboration, the search interface includes a simplified data model and upload procedure, support for online editing of datasets amongst team members, commenting by reviewers and colleagues, and automated contribution workflows and data retrieval through the API. This web application has been designed to generalize to other databases in MagIC's umbrella website (EarthRef.org) so the Geochemical Earth Reference Model (http://earthref.org/GERM/) portal, Seamount Biogeosciences Network (http://earthref.org/SBN/), EarthRef Digital Archive (http://earthref.org/ERDA/) and EarthRef Reference Database (http://earthref.org/ERR/) will benefit from its development.

  1. Enhanced 99 Tc retention in glass waste form using Tc(IV)-incorporated Fe minerals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Um, Wooyong; Luksic, Steven A.; Wang, Guohui

    Technetium (99Tc) immobilization by doping into iron oxide mineral phases may alleviate the problems with Tc volatility during vitrification of nuclear waste. Reduced Tc, Tc(IV), substitutes for Fe(III) in the crystal structure by a process of Tc reduction from Tc(VII) to Tc(IV) followed by co-precipitation of Fe oxide minerals. Two Tc-incorporated Fe minerals (Tc-goethite and Tc-magnetite/maghemite) were prepared and tested for Tc retention in glass melt samples at temperatures between 600 – 1,000 oC. After being cooled, the solid glass specimens prepared at different temperatures were analyzed for Tc oxidation state using Tc K-edge XANES. In most samples, Tc wasmore » partially oxidized from Tc(IV) to Tc(VII) as the melt temperature increased. However, Tc retention in glass melt samples prepared using Tc-incorporated Fe minerals were moderately higher than in glass prepared using KTcO4 because of limited and delayed Tc volatilization.« less

  2. PREFACE: 2014 Joint IMEKO TC1-TC7-TC13 Symposium: Measurement Science Behind Safety and Security

    NASA Astrophysics Data System (ADS)

    Sousa, João A.; Ribeiro, Álvaro S.; Filipe, Eduarda

    2015-02-01

    The 2014 Joint IMEKO (International Measurement Confederation) TC1-TC7-TC13 Symposium was organized by RELACRE - Portuguese Association of Accredited Laboratories and the Portuguese Society for Metrology, on 3-5 September 2014. The work of this symposium is reported in this volume. The scope of the symposium includes the main topics covered by the above Technical Committees: - TC1 Education and Training in measurement and Instrumentation - TC7 Measurement Science - TC13 Measurements in Biology and Medicine The effort towards excellence of previous events, in this well established series, is maintained. There has been a special focus on measurement science behind safety and security, with the aim of highlighting the interdisciplinary character of measurement science and the importance of metrology in our daily lives. The discussion was introduced by keynote lectures on measurement challenges in biometrics, health monitoring and social sciences, to promote useful interactions with scientists from different disciplines. The Symposium was attended by experts working in these areas from 18 countries, including USA, Japan and China, and provided a useful forum for them to share and exchange their work and ideas. In total over fifty papers are included in the volume, organized according to the presentation sessions. Each paper was independently peer-reviewed by two reviewers from a distinguished international panel. The Symposium was held in Funchal, capital of Madeira Islands, known as the Atlantic Pearl. This wonderful Atlantic archipelago, formed by Madeira and Porto Santo islands, discovered in the 14th century, was chosen to host the 2014 IMEKO TC1-TC7-TC13 Joint Symposium ''Measurement Science behind Safety and Security''. It was the first territory discovered by the Portuguese sailors, when set out to discover a new world, in an epic journey where instrumentation and quality of measurement played a central role in the success of the enterprise, and gave an

  3. Tc-99m-galactosyl-neoglycoalbumin (Tc-NGA) liver imaging: Potential application in liver transplantation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woodle, E.S.; Vera, D.R.; Ward, R.E.

    1984-01-01

    Tc-NGA is a hepatocyte receptor-specific imaging agent whose uptake by the liver has been shown to be dependent upon blood flow and receptor concentration. The combination of anatomic and physiologic information obtained with Tc-NGA may provide a new tool for studying hepatic function in liver transplant recipients. To evaluate the potential role of Tc-NGA in liver transplant recipients, studies were performed in four groups of pigs: controls (n=18); common bile duct (CBD) ligation (n=8); orthotopic liver transplant (n=9); and acute hepatic artery ligation (n=1). Serial studies performed in two animals with CBD ligation demonstrated normal imaging anatomy with minor changesmore » in the hepatic time-activity curves when compared to control studies. Studies in liver-transplanted animals showed significant changes in the hepatic time-activity curves during acute rejection and in preservation-related ischemic injury. Tc-NGA also demonstrated focal areas of hepatic infarction in a hepatic allograft within 24 hours of transplantation. The hepatic artery ligation study showed massive changes in the hepatic time-activity curve within two hours after ligation, with a diffuse decrease in hepatic activity. These results indicate that: (1) extrahepatic biliary tract obstruction causes only minor changes in Tc-NGA uptake; (2) Tc-NGA uptake by the liver is very sensitive to acute hepatic ischemia; (3) Tc-NGA may indicate the presence of preservation damage in the early postoperative period; and (4) Tc-NGA hepatic time-activity curves demonstrate significant changes during acute rejection.« less

  4. Enhanced 99Tc retention in glass waste form using Tc(IV)-incorporated Fe minerals

    DOE PAGES

    Um, Wooyong; Luksic, Steven A.; Wang, Guohui; ...

    2017-09-07

    We present that technetium ( 99Tc) immobilization by doping into iron oxide mineral phases may alleviate the problems with Tc volatility during vitrification of nuclear waste. Because reduced Tc, Tc(IV), substitutes for Fe(III) in the crystal structure by a process of Tc reduction from Tc(VII) to Tc(IV) followed by co-precipitation of Fe oxide minerals, two Tc-incorporated Fe minerals (Tc-goethite and Tc-magnetite/maghemite) were prepared and tested for Tc retention in glass melt samples at temperatures between 600 and 1000 °C. After being cooled, the solid glass specimens prepared at different temperatures at 600, 800, and 1000 °C were analyzed for Tcmore » oxidation state using Tc K-edge XANES. In most samples, Tc was partially (<60%) oxidized from Tc(IV) to Tc(VII) as the melt temperature increased up to 600 °C. However, most of Tc(IV) was completely (>95%) oxidized to Tc(VII) at temperature above 800 °C. Tc retention in glass melt samples prepared using Tc-incorporated Fe minerals were slightly higher (~10%) than in glass prepared using KTcO4 because of limited and delayed Tc volatilization.« less

  5. Enhanced 99Tc retention in glass waste form using Tc(IV)-incorporated Fe minerals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Um, Wooyong; Luksic, Steven A.; Wang, Guohui

    We present that technetium ( 99Tc) immobilization by doping into iron oxide mineral phases may alleviate the problems with Tc volatility during vitrification of nuclear waste. Because reduced Tc, Tc(IV), substitutes for Fe(III) in the crystal structure by a process of Tc reduction from Tc(VII) to Tc(IV) followed by co-precipitation of Fe oxide minerals, two Tc-incorporated Fe minerals (Tc-goethite and Tc-magnetite/maghemite) were prepared and tested for Tc retention in glass melt samples at temperatures between 600 and 1000 °C. After being cooled, the solid glass specimens prepared at different temperatures at 600, 800, and 1000 °C were analyzed for Tcmore » oxidation state using Tc K-edge XANES. In most samples, Tc was partially (<60%) oxidized from Tc(IV) to Tc(VII) as the melt temperature increased up to 600 °C. However, most of Tc(IV) was completely (>95%) oxidized to Tc(VII) at temperature above 800 °C. Tc retention in glass melt samples prepared using Tc-incorporated Fe minerals were slightly higher (~10%) than in glass prepared using KTcO4 because of limited and delayed Tc volatilization.« less

  6. Synthesis and comparative in vivo evaluation of 99m Tc(CO)3 -labeled PEGylated and non-PEGylated cRGDfK peptide monomers.

    PubMed

    Vats, Kusum; Satpati, Drishty; Sharma, Rohit; Sarma, Haladhar D; Banerjee, Sharmila

    2017-03-01

    This work aimed at studying the effect of insertion of medium PEG (PEG 7 ) on the pharmacokinetic behavior of cRGDfK peptide in comparison with the non-PEGylated analogue. The cRGDfK peptide has thus been derivatized at ε-amino group of lysine by conjugation with N 3 -PEG 7 -COOH/N 3 -CH 2 -COOH to prepare a PEGylated and a non-PEGylated analogue of cRGDfK. A tridentate chelator was then incorporated by click chemistry conjugation of the two peptide azides for radiolabeling with [ 99m Tc(CO) 3 (H 2 O) 3 ] + precursor. Comparative in vivo evaluation of the two 99m Tc(CO) 3 -labeled radiotracers, 99m Tc(CO) 3 -Pra-Tz-CH 2 -cRGDfK 5 and 99m Tc(CO) 3 -Pra-Tz-PEG 7 -cRGDfK 6, was carried out in C57BL/6 mice bearing α v β 3 -positive melanoma tumors to determine their potential toward targeting integrin α v β 3 receptors. The radiotracers exhibited excellent stability in saline as well as in serum. Maximum tumor uptake for the two radiotracers was observed at 30 min p.i. (5: 3.0 ± 0.7% ID/g; 6: 4.1 ± 0.5% ID/g). The two neutral 99m Tc(CO) 3 radiotracers prepared exhibited receptor-mediated uptake in melanoma tumor. The increase in the tumor uptake on introduction of PEG 7 unit was accompanied by slower clearance from other organs which resulted in decreased target-to-background ratios. The in vivo kinetics of 99m Tc(CO) 3 -labeled radiotracer, 99m Tc(CO) 3 -Pra-Tz-CH 2 -cRGDfK 5 with only methylene unit as the spacer, was found to be more favorable due to higher tumor/blood, tumor/liver, tumor/kidney, and tumor/lung ratios. © 2016 John Wiley & Sons A/S.

  7. Knockout of the CCCH zinc finger protein TcZC3H31 blocks Trypanosoma cruzi differentiation into the infective metacyclic form.

    PubMed

    Alcantara, Monica Visnieski; Kessler, Rafael Luis; Gonçalves, Rosana Elisa Gonçalves; Marliére, Newmar Pinto; Guarneri, Alessandra Aparecida; Picchi, Gisele Fernanda Assine; Fragoso, Stenio Perdigão

    2018-04-01

    In the protozoan parasite Trypanosoma cruzi - the causative agent of Chagas disease - gene expression control is mainly post-transcriptional, where RNA-binding proteins (RBPs) play a central role, by controlling mRNA stability, distribution and translation. A large variety of RBPs are encoded in the T. cruzi genome, including the CCCH-type zinc finger (CCCH ZnF) protein family, which is characterized by the presence of the C-X 7/8 -C-X 5 -C-X 3 -H (CCCH) motif. In the related parasite T. brucei, CCCH ZnF proteins have been shown to control key differentiation steps in the parasite's life cycle. However, little is known about the CCCH ZnF proteins in T. cruzi. We have worked on the generation of T. cruzi mutants for CCCH ZnF proteins in an effort to shed light on the functions of these proteins in this parasite. Here, we characterize the expression and function of the CCCH ZnF protein TcZC3H31 of T. cruzi. TcZC3H31 is almost exclusively expressed in epimastigotes and metacyclic trypomastigotes, the parasite forms found in the invertebrate host. Importantly, we show that the epimastigote form of the T. cruzi knockout for the TcZC3H31 gene (TcZC3H31 KO) is incapable, both in vitro and in vivo (in infected triatomine insects), to differentiate into the metacyclic trypomastigote form, which is responsible for infection transmission from vectors to humans. The epimastigote forms recovered from the excreta of insects infected with TcZC3H31 KO parasites do not have the typical epimastigote morphology, suggesting that parasites are arrested in a mid-differentiation step. Also, epimastigotes overexpressing TcZC3H31 differentiate into metacyclics more efficiently than wild-type epimastigotes, in vitro. These data suggest that TcZC3H31 is an essential positive regulator of T. cruzi differentiation into the human-infective metacyclic form. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Targeted imaging of gastrin-releasing peptide receptors with 99mTc-EDDA/HYNIC-[Lys3]-bombesin: biokinetics and dosimetry in women.

    PubMed

    Santos-Cuevas, Clara L; Ferro-Flores, Guillermina; Arteaga de Murphy, Consuelo; Pichardo-Romero, Pablo A

    2008-08-01

    The gastrin-releasing peptide receptor (GRP-R) is expressed in several normal human tissues and is overexpressed in various human tumors including breast, prostate, small-cell lung cancer and pancreatic cancer. Recently, 99mTc-EDDA/HYNIC-[Lys]-bombesin (99mTc-HYNIC-BN) was reported as a radiopharmaceutical with high stability in human serum, specific cell GRP-R binding and rapid cell internalization. The aim of this study was to determine the biokinetics and dosimetry of 99mTc-HYNIC-BN and the feasibility of using this radiopharmaceutical to image GRP-R in four early breast cancer patients and seven healthy women. Whole-body images were acquired at 20, 90, 180 min, and 24 h after 99mTc-HYNIC-BN administration. The same regions of interest were drawn around source organs on each time frame and regions of interest were converted to activity (conjugate view counting method). The image sequence was used to extrapolate 99mTc-HYNIC-BN time-activity curves in each organ to calculate the total number of disintegrations (N) that occurred in the source regions. N data were the input for the OLINDA/EXM code to calculate internal radiation dose estimates. 99mTc-HYNIC-BN had a rapid blood clearance with mainly renal excretion. No statistically significant differences (P>0.05) in the radiation-absorbed doses among cancer patients and healthy women were observed. The average equivalent doses (n=11) were 24.8+/-8.8 mSv (kidneys), 7.3+/-1.8 mSv (lungs), 6.5+/-4.0 mSv (breast), 2.0+/-0.3 mSv (pancreas), 1.6+/-0.3 mSv (liver), 1.2+/-0.2 mSv (ovaries), and 1.0+/-0.2 mSv (red marrow). The effective dose was 3.3+/-0.6 mSv. The images showed well-differentiated concentration of 99mTc-HYNIC-BN in cancer mammary tissue. All the absorbed doses were comparable with those known for most of the 99mTc studies. 99mTc-HYNIC-BN shows high tumor uptake in breasts with malignant tumors so it is a promising imaging radiopharmaceutical to target site-specific early breast cancer. The results obtained

  9. Characteristics of YBa2Cu3O7 high-Tc superconductor with KCl

    NASA Astrophysics Data System (ADS)

    Yoon, Ki Hyun; Chang, Sung Sik

    1990-03-01

    The lattice parameters, microstructural change, transition temperature, and electrical properties of the YBa2-xKxCu3O7 high-Tc superconductor in the range from x=0 to x=0.25 have been investigated. The high-Tc orthorhombic phase increases with increasing KCl up to x=0.20, above which it decreases. The lattice parameters decrease with increasing KCl up to x=0.10, and then become nearly uniform. The grain size increases with increasing KCl up to x=0.20 due to its role as sintering agent. The specimens with x=0.2 have transition temperatures of 96 K and high magnetic susceptibility due to the contraction of lattice parameters a and b and the increase of orthorhombic distortion.

  10. Spectroscopic Analysis of 10MAG/LDAO Reverse Micelles to Determine Characteristic Properties and Behavioral Extrema

    NASA Astrophysics Data System (ADS)

    Berg, Joshua; Mawson, Cara; Norris, Zach; Nucci, Nathaniel

    Reverse micelles are spontaneously organizing complexes of surfactant that encapsulate a nanoscale pool of water in a bulk non-polar solvent. Reverse micelle (RM) mixtures have a wide range of applications, including biophysical investigation of protein systems. A new RM mixture composed of decyl-1-monoglycerol (10MAG) and lauryldimethylammonium-N-oxide (LDAO) was recently described. This mixture has the potential to prove more widely applicable for use of RMs in applications that involve encapsulation of macromolecules, yet little is known about the phase behavior or size of reverse micelles created by this mixture. Data describing such behaviors for this mixture are presented here. We have used dynamic light scattering (DLS) and fluorescence spectroscopy to investigate the size and partitioning behavior of RMs in varying mixtures of 10MAG, LDAO, water, pentane, and hexanol. These data demonstrate that the 10MAG/LDAO RM mixture exhibits markedly different phase and RM size behavior than that of commonly used RM surfactant mixtures. The implications of these findings for use of the 10MAG/LDAO mix for RM applications will also be addressed. Funding provided by Rowan University.

  11. MAG traffic generator study : survey data from Arizona State University

    DOT National Transportation Integrated Search

    1994-12-01

    The Maricopa Association of Governments (MAG) is responsible for the travel demand models used to forecast multi-modal travel behavior in the Phoenix metropolitan area. The main campus of Arizona State University (ASU), located in Tempe, is one of th...

  12. 76 FR 46330 - NUREG-1934, Nuclear Power Plant Fire Modeling Application Guide (NPP FIRE MAG); Second Draft...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-02

    ... NUCLEAR REGULATORY COMMISSION [NRC-2009-0568] NUREG-1934, Nuclear Power Plant Fire Modeling Application Guide (NPP FIRE MAG); Second Draft Report for Comment AGENCY: Nuclear Regulatory Commission... 1023259), ``Nuclear Power Plant Fire Modeling Application Guide (NPP FIRE MAG), Second Draft Report for...

  13. Magnetically Responsive Optical Nanoprobes (MagRONs) and Systems

    DTIC Science & Technology

    2004-02-28

    5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) 8. PERFORMING ORGANIZATION REPORT NUMBER The regents of the University of...research. MagMOON Architechtures I Controlled deposition of magnetic materials onto any nanosensor Prism coated nanoparticles Electric field sensors...into a predefined pattern has been the focus of many investigations.[7-11] For example, strawberry-like composite materials using organic -inorganic

  14. Apolipoprotein C3 (-455T>C) polymorphism confers susceptibility to nonalcoholic fatty liver disease in the Southern Han Chinese population

    PubMed Central

    Li, Min-Rui; Zhang, Sheng-Hong; Chao, Kang; Liao, Xian-Hua; Yao, Jia-Yan; Chen, Min-Hu; Zhong, Bi-Hui

    2014-01-01

    AIM: To investigate the relationship between Apolipoprotein C3 (APOC3) (-455T>C) polymorphism and nonalcoholic fatty liver disease (NAFLD) in the Southern Chinese Han population. METHODS: In this prospective case-control study, we recruited 300 NAFLD patients and 300 healthy controls to a cohort representing Southern Chinese Han population at The First Affiliated Hospital, Sun Yat-sen University, from January to December 2012. Polymerase chain reaction-restriction fragment length polymorphism and DNA sequencing were used to genotype the APOC3 (-455T>C) variants. RESULTS: After adjusting for age, gender, and body-mass index, TC and CC genotypes were found to increase the susceptibility to NAFLD compared to the TT genotype, with adjusted odds ratios (ORs) of 1.77 (95%CI: 1.16-2.72) and 2.80 (95%CI: 1.64-4.79), respectively. Further stratification analysis indicated that carriers of the CC genotype was more susceptible to insulin resistance (IR) than those of the TT genotype, with an OR of 3.24 (95%CI: 1.52-6.92). The CC genotype also was associated with a significantly higher risk of hypertension, hypertriglyceridemia, and low levels of high-density lipoprotein cholesterol (HDL) (P < 0.05). No association was found between the APOC3 (-455T>C) polymorphism and obesity, impaired glucose tolerance, hyperuricemia, hypercholesterolemia, or high levels of low-density lipoprotein cholesterol (LDL) (P > 0.05). CONCLUSION: APOC3 (-455T>C) genetic variation is involved in the susceptibility to developing NAFLD, IR, hypertension, hypertriglyceridemia, and low HDL in the Southern Chinese Han population. PMID:25320541

  15. The Effect of External Magnetic Fields on the MRT Instability in MagLIF

    NASA Astrophysics Data System (ADS)

    Hess, Mark; Peterson, Kyle; Weis, Matthew; Lau, Yue Ying

    2014-10-01

    Recent experiments on MagLIF which incorporate an external B-field suggest that the MRT instability within the liner has a different behavior than without the B-field. Previous work by Chandrasekhar and Harris have illustrated how the MRT growth rate, assuming fixed liner density and fixed acceleration, can change due to the presence of an external B-field. In this work, we show how the growth rate of the MRT instability is dynamically affected by the rapidly varying acceleration, liner density, and surface magnetic field, which is composed of the external B-field and the drive B-field of the liner in the MagLIF experiments. In addition, we also examine the effects of finite liner resistivity on MRT growth, which gives rise to an additional time scale corresponding to magnetic diffusion. We discuss the implications of this result for future MagLIF designs. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy under Contract DE-AC04-94AL85000.

  16. Modulation of in vivo distribution through chelator: Synthesis and evaluation of a 2-nitroimidazole-dipicolylamine-(99m)Tc(CO)3 complex for detecting tumor hypoxia.

    PubMed

    Mallia, Madhava B; Mittal, Sweety; Sarma, Haladhar D; Banerjee, Sharmila

    2016-01-01

    Previous studies have clearly demonstrated strong correlation between in vivo distribution and blood clearance of radiopharmaceuticals for the detection of hypoxia. Present study describes an attempt to improve the in vivo distribution of a previously reported 2-nitroimidazole-(99m)Tc(CO)3 complex by tuning its blood clearance pattern through structural modification of the ligand. Herein, a 2-nitroimidazole-dipicolylamine ligand (2-nitroimidazole-DPA) was synthesized in a two-step procedure and radiolabeled with (99m)Tc(CO)3 core. Subsequently, the complex was evaluated in Swiss mice bearing fibrosarcoma tumor. As intended by its design, 2-nitroimidazole-DPA-(99m)Tc(CO)3 complex was more lipophilic than previously reported 2-nitroimidazole-DETA-(99m)Tc(CO)3 complex (DETA-diethylenetriamine) and showed slower blood clearance. Consequently it showed higher tumor uptake than 2-nitroimidazole-DETA-(99m)Tc(CO)3 complex. Significantly, despite structural modifications, other parameters such as the tumor to blood ratio and tumor to muscle ratio of the 2-nitroimidazole-DPA-(99m)Tc(CO)3 complex remained comparable to that of 2-nitroimidazole-DETA-(99m)Tc(CO)3 complex. Present study demonstrates the feasibility of structural modifications for improving in vivo tumor uptake of hypoxia detecting radiopharmaceuticals. This might encourage researchers to improve suboptimal properties of a potential radiopharmaceuticals rather than ignoring it altogether. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Vertical distributions of (99)Tc and the (99)Tc/(137)Cs activity ratio in the coastal water off Aomori, Japan.

    PubMed

    Nakanishi, Takahiro; Zheng, Jian; Aono, Tatsuo; Yamada, Masatoshi; Kusakabe, Masashi

    2011-08-01

    Using a sector-field ICP-MS the vertical distributions of the (99)Tc concentration and (99)Tc/(137)Cs activity ratio were measured in the coastal waters off Aomori Prefecture, Japan, where a spent-nuclear-fuel reprocessing plant has begun test operation. The (99)Tc concentrations in surface water ranged from 1.8 to 2.4 mBq/m(3), no greater than the estimated background level. Relatively high (99)Tc/(137)Cs activity ratios (10-12 × 10(-4)) would be caused by the inflow of the high-(99)Tc/(137)Cs water mass from the Japan Sea. There is no observable contamination from the reprocessing plant in the investigated area. The (99)Tc concentration and the (99)Tc/(137)Cs activity ratio in water column showed gradual decreases with depth. Our results implied that (99)Tc behaves in a more conservative manner than (137)Cs in marine environments. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. How MAG4 Improves Space Weather Forecasting

    NASA Technical Reports Server (NTRS)

    Falconer, David; Khazanov, Igor; Barghouty, Nasser

    2013-01-01

    Dangerous space weather is driven by solar flares and Coronal Mass Ejection (CMEs). Forecasting flares and CMEs is the first step to forecasting either dangerous space weather or All Clear. MAG4 (Magnetogram Forecast), developed originally for NASA/SRAG (Space Radiation Analysis Group), is an automated program that analyzes magnetograms from the HMI (Helioseismic and Magnetic Imager) instrument on NASA SDO (Solar Dynamics Observatory), and automatically converts the rate (or probability) of major flares (M- and X-class), Coronal Mass Ejections (CMEs), and Solar Energetic Particle Events.

  19. Hairy cell leukaemia complicated by anti-MAG paraproteinemic demyelinating neuropathy: resolution of neurological syndrome after cladribrine treatment.

    PubMed

    Rossi, Davide; Franceschetti, Silvia; Cerri, Michaela; Conconi, Annarita; Lunghi, Monia; Capello, Daniela; Cantello, Roberto; Gaidano, Gianluca

    2007-06-01

    Hairy cell leukaemia (HCL) occasionally displays a monoclonal gammopathy, yet the association of HCL with paraproteinemic demyelinating neuropathy (PDN) has not been reported. We describe a HCL case complicated by PDN and high titers of monoclonal IgM against myelin associated glycoprotein (MAG). Heavy and light chains of the patient's anti-MAG monoclonal protein were consistent with those expressed by HCL cells. After treatment with cladribrine, remission of HCL strictly paralleled disappearance of the IgM monoclonal protein and of the serum anti-MAG activity, and led to PDN clinical and electrophysiological improvement. Purine analogs may represent a choice in IgM PDN associated with lymphoproliferative disorders.

  20. Two novel elements (CFG1 and PYG1) of Mag lineage of Ty3/Gypsy retrotransposons from Zhikong scallop (Chlamys farreri) and Japanese scallop (Patinopecten yessoensis).

    PubMed

    Wang, Shi; Bao, Zhenmin; Hu, Xiaoli; Shao, Mingyu; Zhang, Lingling; Hu, Jingjie

    2008-05-01

    Two novel elements (CFG1 and PYG1) of Mag lineage of Ty3/Gypsy retrotransposons were cloned from Zhikong scallop (Chlamys farreri) and Japanese scallop (Patinopecten yessoensis). The total length of the CFG1 element is 4826 bp, including 5'-LTR (192 bp), the entire ORF (4047 bp) and 3'-LTR (189 bp). The entire ORFs of both CFG1 and PYG1 elements are composed of 1348 aa and do not have any frameshifts. Their closest relative is Jule element from the poeciliid fish (Xiphophorus maculatus). On average, the diploid genome of C. farreri contains approximately 84 copies of CFG1 elements. We summarize the major features of CFG1, PYG1 and other elements of Mag lineage of the Ty3/Gypsy group. mRNA expression of CFG1 element in larvae increases gradually before the gastrulae stage and decreases gradually afterward, whereas in adductor such expression in adductor muscle and digestive gland are lower than those in other tissues. Overall, mRNA expression of CFG1 element in the early larvae is significantly higher than that in adult tissues. In muscle tissue, while the promoter and partial GAG domain of CFG1 element are unmethylated, the partial RT domain is highly methylated. These results suggest that CFG1 expression may be controlled by a post-transcriptional gene silencing mechanism that is associated with coding-region (RT domain) methylation.

  1. Diuretic renography in hydronephrosis: delayed tissue tracer transit accompanies both functional decline and tissue reorganization.

    PubMed

    Schlotmann, Andreas; Clorius, John H; Rohrschneider, Wiltrud K; Clorius, Sandra N; Amelung, Folker; Becker, Kristianna

    2008-07-01

    The significance of delayed tissue tracer transit (TTT) of (99m)Tc-mercaptoacetyltriglycine ((99m)Tc-MAG3) has not been systematically evaluated in hydronephrosis. We sought to demonstrate that delayed TTT accompanies both functional decline and histomorphologic restructuring. Twenty 2- to 3-mo-old piglets with surgically induced partial unilateral ureteral stenosis were examined with magnetic resonance urography (MRU) to evaluate morphology and with (99m)Tc-MAG3 diuretic renography (DR) to determine single-kidney function (SKF), evaluate the response to furosemide stimulation (RFS), and assess TTT. All animals had DR and MRU before and after surgery and a third DR after surgery. Piglets were sacrificed after the final DR for renal histology. A total histologic score (THS) was generated. Preoperative DR demonstrated nonobstructive RFS, timely TTT, and balanced SKF in all 20 kidneys. After ureteral ligature, MRU demonstrated pelvic dilatation in all piglets. The postoperative DRs revealed 12 kidneys with delayed TTT in one or both follow-ups. In these 12 kidneys, the SKF declined from 51% +/- 4% to 18% +/- 14%, and the THS was 9.0 +/- 4.0. Three kidneys always had timely TTT, balanced SKF, and a THS of 1.8 +/- 0.3. The contralateral, nonoperated kidneys had timely TTT and a THS of 1.2 +/- 0.9. Postoperative scintigrams showed that 3 of 8 kidneys (38%) with an obstructive RFS had timely TTT, which demonstrates that TTT and RFS are not equivalent. In hydronephrosis, a delayed TTT of (99m)Tc-MAG3 accompanies both functional decline and histomorphologic restructuring in obstruction. According to the literature, a delayed TTT is determined by the filtration fraction of the kidneys and appears to identify an obstruction-mediated upregulated renin-angiotensin system.

  2. Molecular and biochemical characterisation of two aspartic proteinases TcAP1 and TcAP2 from Theobroma cacao seeds.

    PubMed

    Laloi, Maryse; McCarthy, James; Morandi, Olivia; Gysler, Christof; Bucheli, Peter

    2002-09-01

    Aspartic proteinase (EC 3.4.23) activity plays a pivotal role in the degradation of Theobroma cacao L. seed proteins during the fermentation step of cacao bean processing. Therefore, this enzyme is believed to be critical for the formation of the peptide and amino acid cocoa flavor precursors that occurs during fermentation. Using cDNA cloning and northern blot analysis, we show here that there are at least two distinct aspartic proteinase genes ( TcAP1 and TcAP2) expressed during cacao seed development. Both genes are expressed early during seed development and their mRNA levels decrease towards the end of seed maturation. TcAP2 is expressed at a much higher level than TcAP1, although the expression of TcAP1 increases slightly during germination. The proteins encoded by TcAP1 and TcAP2 are relatively different from each other (73% identity). This, and the fact that the two corresponding genes have different expression patterns, suggests that the TcAP1 and TcAP2 proteins may have different functions in the maturing seeds and during germination. Because the TcAP2 gene is expressed at a much higher level during seed development than TcAP1, it is likely that the TcAP2 protein is primarily responsible for the majority of the industrially important protein hydrolysis that occurs during cacao bean fermentation. Finally, TcAP2 has been functionally expressed in the yeast Yarrowia lipolytica. The secreted recombinant protein is able to hydrolyse bovine haemoglobin at acidic pH and is sensitive to pepstatin A, confirming that TcAP2 encodes an aspartic proteinase, and strongly suggests that this gene encodes the well-characterized aspartic proteinase of mature cacao seeds.

  3. The Theobroma cacao B3 domain transcription factor TcLEC2 plays a duel role in control of embryo development and maturation.

    PubMed

    Zhang, Yufan; Clemens, Adam; Maximova, Siela N; Guiltinan, Mark J

    2014-04-24

    The Arabidopsis thaliana LEC2 gene encodes a B3 domain transcription factor, which plays critical roles during both zygotic and somatic embryogenesis. LEC2 exerts significant impacts on determining embryogenic potential and various metabolic processes through a complicated genetic regulatory network. An ortholog of the Arabidopsis Leafy Cotyledon 2 gene (AtLEC2) was characterized in Theobroma cacao (TcLEC2). TcLEC2 encodes a B3 domain transcription factor preferentially expressed during early and late zygotic embryo development. The expression of TcLEC2 was higher in dedifferentiated cells competent for somatic embryogenesis (embryogenic calli), compared to non-embryogenic calli. Transient overexpression of TcLEC2 in immature zygotic embryos resulted in changes in gene expression profiles and fatty acid composition. Ectopic expression of TcLEC2 in cacao leaves changed the expression levels of several seed related genes. The overexpression of TcLEC2 in cacao explants greatly increased the frequency of regeneration of stably transformed somatic embryos. TcLEC2 overexpressing cotyledon explants exhibited a very high level of embryogenic competency and when cultured on hormone free medium, exhibited an iterative embryogenic chain-reaction. Our study revealed essential roles of TcLEC2 during both zygotic and somatic embryo development. Collectively, our evidence supports the conclusion that TcLEC2 is a functional ortholog of AtLEC2 and that it is involved in similar genetic regulatory networks during cacao somatic embryogenesis. To our knowledge, this is the first detailed report of the functional analysis of a LEC2 ortholog in a species other then Arabidopsis. TcLEC2 could potentially be used as a biomarker for the improvement of the SE process and screen for elite varieties in cacao germplasm.

  4. The Theobroma cacao B3 domain transcription factor TcLEC2 plays a duel role in control of embryo development and maturation

    PubMed Central

    2014-01-01

    Background The Arabidopsis thaliana LEC2 gene encodes a B3 domain transcription factor, which plays critical roles during both zygotic and somatic embryogenesis. LEC2 exerts significant impacts on determining embryogenic potential and various metabolic processes through a complicated genetic regulatory network. Results An ortholog of the Arabidopsis Leafy Cotyledon 2 gene (AtLEC2) was characterized in Theobroma cacao (TcLEC2). TcLEC2 encodes a B3 domain transcription factor preferentially expressed during early and late zygotic embryo development. The expression of TcLEC2 was higher in dedifferentiated cells competent for somatic embryogenesis (embryogenic calli), compared to non-embryogenic calli. Transient overexpression of TcLEC2 in immature zygotic embryos resulted in changes in gene expression profiles and fatty acid composition. Ectopic expression of TcLEC2 in cacao leaves changed the expression levels of several seed related genes. The overexpression of TcLEC2 in cacao explants greatly increased the frequency of regeneration of stably transformed somatic embryos. TcLEC2 overexpressing cotyledon explants exhibited a very high level of embryogenic competency and when cultured on hormone free medium, exhibited an iterative embryogenic chain-reaction. Conclusions Our study revealed essential roles of TcLEC2 during both zygotic and somatic embryo development. Collectively, our evidence supports the conclusion that TcLEC2 is a functional ortholog of AtLEC2 and that it is involved in similar genetic regulatory networks during cacao somatic embryogenesis. To our knowledge, this is the first detailed report of the functional analysis of a LEC2 ortholog in a species other then Arabidopsis. TcLEC2 could potentially be used as a biomarker for the improvement of the SE process and screen for elite varieties in cacao germplasm. PMID:24758406

  5. Toxicology and Carcinogenesis Studies of Mixtures of 3'-Azido-3'-Deoxythymidine (AZT), Lamivudine (3TC), and Nevirapine (NVP) (CAS Nos. 30516-87-1, 134678-17-4, 129618-40-2) in Genetically Modified C3B6.129F1-Trp53(tm1Brd) N12 Haploinsufficient Mice (in utero and postnatal gavage studies).

    PubMed

    2013-10-01

    3'-Azido-3'-deoxythymidine (AZT) is the most widely used and evaluated chemotherapeutic agent for the treatment of persons with acquired immune deficiency syndrome (AIDS). Antiviral therapy is essential for treatment and prevention of AIDS in adults and children infected with human immunodeficiency virus (HIV), and to prevent mother-to-child transmission of HIV during pregnancy and labor. The studies described in this report were designed to determine possible long-term sequelae from AZT treatment, often used in combination with other antiviral drugs, such as lamivudine (3TC) and nevirapine (NVP) in preventing mother-to-child transmission of HIV. Male and female heterozygous F1 p53+/- mice were exposed to AZT, 3TC, NVP, or combinations of the chemicals in utero on gestation days (GD) 12 through 18, then administered the same chemical or combination of chemicals by gavage from postnatal day (PND) 1 through PND 28 and then observed until 45 weeks of age. Vehicle control mice received only an aqueous solution containing 0.2% methylcellulose and 0.1% Tween 80. Mice were dosed twice daily until PND 28. Genetic toxicology studies were conducted in mouse peripheral blood erythrocytes. The study compared three combination doses of AZT, 3TC and NVP (AZT/3TC/NVP-L, AZT/3TC/NVP-M, and AZT/3TC/NVP-H) with the vehicle controls, and compared the individual components with each other at the highest dose (AZT-H, 3TC-H, NVP-H, AZT/3TC-H and AZT/3TC/NVP-H). Because exposure to AZT/3TC/NVP-M and AZT/3TC/NVP-H reduced pup survival, additional litters were required to provide sufficient pups to load the 45-week study. 45-WEEK STUDY: In general, survival was relatively high once the pup exposure phase had been completed, with at least 75% of the mice surviving to terminal sacrifice in all groups. For males, survival was significantly greater in the AZT/3TC/NVP-L and AZT/3TC/NVP-M groups relative to the vehicle control group. There were no significant differences in survival between high

  6. Altered [99mTc]Tc-MDP biodistribution from neutron activation sourced 99Mo.

    PubMed

    Demeter, Sandor; Szweda, Roman; Patterson, Judy; Grigoryan, Marine

    2018-01-01

    Given potential worldwide shortages of fission sourced 99 Mo/ 99m Tc medical isotopes there is increasing interest in alternate production strategies. A neutron activated 99 Mo source was utilized in a single center phase III open label study comparing 99m Tc, as 99m Tc Methylene Diphosphonate ([ 99m Tc]Tc-MDP), obtained from solvent generator separation of neutron activation produced 99 Mo, versus nuclear reactor produced 99 Mo (e.g., fission sourced) in oncology patients for which an [ 99m Tc]Tc-MDP bone scan would normally have been indicated. Despite the investigational [ 99m Tc]Tc-MDP passing all standard, and above standard of care, quality assurance tests, which would normally be sufficient to allow human administration, there was altered biodistribution which could lead to erroneous clinical interpretation. The cause of the altered biodistribution remains unknown and requires further research.

  7. Diagnostic accuracy of 3T magnetic resonance imaging in the preoperative localisation of parathyroid adenomas: comparison with ultrasound and 99mTc-sestamibi scans.

    PubMed

    Argirò, Renato; Diacinti, Daniele; Sacconi, Beatrice; Iannarelli, Angelo; Diacinti, Davide; Cipriani, Cristiana; Pisani, Daniela; Romagnoli, Elisabetta; Biffoni, Marco; Di Gioia, Cira; Pepe, Jessica; Bezzi, Mario; Letizia, Claudio; Minisola, Salvatore; Catalano, Carlo

    2018-05-07

    To evaluate the diagnostic performance of 3TMRI in comparison with ultrasound (US) and 99mTc-sestamibi scan for presurgical localisation of parathyroid adenomas (PTAs) in patients with primary hyperparathyroidism (PHPT). Fifty-seven patients affected by PHPT were prospectively enrolled and underwent US, 99mTc-sestamibi and 3TMRI. T2-weighted and post-contrast T1-weighted Iterative decomposition of water and fat with Echo Asymmetry and Least squares estimation (IDEAL) sequences were acquired. Diagnostic performance of US, 99mTc-sestamibi and MRI in localising PTAs to correct quadrant were compared according to surgical and pathological findings. According to surgical findings, US correctly localised 41/46 PTAs (sensitivity of 89.1%; specificity 97.5%; PPV 93.1% and NPV 95.6%); 99mTc-sestamibi correctly localised 38/46 PTAs (sensitivity 83.6%, specificity 98.3%, PPV 95% and NPV 93.7%). US and 99mTc-sestamibi combined had a sensitivity of 93.4% (43/46 PTAs), specificity of 98.3%, PPV 95% and NPV 98.3%. MRI correctly localised 45/46 PTAs (sensitivity 97.8%; specificity 97.5%; PPV 93.7% and NPV 99.2%). MRI was able to detect six adenomas missed by 99mTc-sestamibi and two adenomas missed by US. MRI and US were able to detect all enlarged parathyroid glands in patients with multiglandular disease. MRI identified six of seven ectopic adenomas. Our study demonstrated high diagnostic performance of 3T MRI in the preoperative PTAs quadrant localisation, as well as in patients with multiglandular disease and ectopic PTAs. MRI may be preferred to adequately select patient candidates for minimally invasive parathyroidectomy (MIP). • PTA(s) quadrant localisation by 3TMRI was more accurate than US+99mTc-sestamibi. • MRI identified all enlarged glands in multiglandular disease similarly to US. • MRI identified 6/7 ectopic PTAs similarly to 99mTc-sestamibi. • Presurgical PTA(s) localisation by 3TMRI select the optimal candidates for MIP.

  8. Managing Rock and Paleomagnetic Data Flow with the MagIC Database: from Measurement and Analysis to Comprehensive Archive and Visualization

    NASA Astrophysics Data System (ADS)

    Koppers, A. A.; Minnett, R. C.; Tauxe, L.; Constable, C.; Donadini, F.

    2008-12-01

    The Magnetics Information Consortium (MagIC) is commissioned to implement and maintain an online portal to a relational database populated by rock and paleomagnetic data. The goal of MagIC is to archive all measurements and derived properties for studies of paleomagnetic directions (inclination, declination) and intensities, and for rock magnetic experiments (hysteresis, remanence, susceptibility, anisotropy). Organizing data for presentation in peer-reviewed publications or for ingestion into databases is a time-consuming task, and to facilitate these activities, three tightly integrated tools have been developed: MagIC-PY, the MagIC Console Software, and the MagIC Online Database. A suite of Python scripts is available to help users port their data into the MagIC data format. They allow the user to add important metadata, perform basic interpretations, and average results at the specimen, sample and site levels. These scripts have been validated for use as Open Source software under the UNIX, Linux, PC and Macintosh© operating systems. We have also developed the MagIC Console Software program to assist in collating rock and paleomagnetic data for upload to the MagIC database. The program runs in Microsoft Excel© on both Macintosh© computers and PCs. It performs routine consistency checks on data entries, and assists users in preparing data for uploading into the online MagIC database. The MagIC website is hosted under EarthRef.org at http://earthref.org/MAGIC/ and has two search nodes, one for paleomagnetism and one for rock magnetism. Both nodes provide query building based on location, reference, methods applied, material type and geological age, as well as a visual FlashMap interface to browse and select locations. Users can also browse the database by data type (inclination, intensity, VGP, hysteresis, susceptibility) or by data compilation to view all contributions associated with previous databases, such as PINT, GMPDB or TAFI or other user

  9. MagAl: A new tool to analyse galaxies photometric data

    NASA Astrophysics Data System (ADS)

    Schoenell, W.; Benítez, N.; Cid Fernandes, R.

    2014-10-01

    On galaxy spectra, one can find mainly two features: emission lines, which tell us about the ionised gas content, and the continuum plus absorption lines, which tell us about the stellar content. They thus allow us to derive gas-phase abundances, the main radiation sources, chemical enrichment and star formation histories. Braad-band photometry, on the other hand, is much more limited and hinders our ability to recover a galaxy's physical properties to such a degree of detail. However, with the recent development of redshift surveys using the technology of ultra-narrow filters (≍ 100 Å), such as ALHAMBRA, J-PAS and DES, it will be invaluable to be able to retrieve information on physical properties of galaxies from photometric data. Motivated by this data avalanche (which goes up to the petabyte scale), we decided to build our own SED-fitting code: Magnitudes Analyser (MagAl), which has three modules. 1) A template library generation module: generates empirical and theoretical template libraries. 2) Bayesian fitting module: calculates probability distribution functions (PDFs) for given observed and library template data. This is similar to the method to measure photometric redshifts by Benitez (2000). 3) A result-analyser module: streamlines data analysis from the large output PDFs files. A fourth module to manage 3D data is being developed and a few preliminary tests are also shown. To investigate the reliability of results obtained by MagAl, we have created a mock galaxy sample for the ALHAMBRA survey filter system (http://alhambrasurvey.com) and tried to recover their physical properties. We show that for our sample of simulated galaxies we can measure stellar ages, metallicities and extinctions with a precision of less than 0.3 dex. Also, we apply the code to the ALHAMBRA survey catalog and show that we can measure stellar masses with an accuracy of 0.2 dex when comparing to previous results like COSMOS masses measured by Bundy et al. (2006).

  10. Measuring functioning hepatocytes using Tc-99m galactosylneoglycoalbumin (Tc-NGA)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stadalnik, R.C.; Vera, D.R.; Quadro, R.E.

    1984-01-01

    Tc-NGA is a synthetic ligand which binds only to hepatic binding protein (HBP), a receptor found only in the liver. It exhibits the properties of high tissue specificity, affinity-dependent uptake, and dose-dependent uptake. Tc-NGA provides an opportunity to study the functioning hepatocyte. The authors evaluated the usefulness of this technique in patients with hepatitis and hepatoma. After intravenous administration of 5 mCi Tc-NGA, dynamic images were acquired for 30 minutes followed by static views. Estimates of HBP concentrations were obtained by kinetic analysis of blood and liver time-activity curves. Kinetic estimates (reduced chi-squares < 3.0) of HBP correlated well withmore » the clinical course and histology. For example, a patient with hepatoma whose calculated receptor population (functioning hepatocytes) was 3.0 +- 0.9 x 10/sup -7/ mole, which is the normal range, is doing well undergoing chemotherapy. Liver biopsy demonstrated normal liver tissue except for the hepatoma. Another patient with hepatoma who had a severely depressed receptor population, 1.2 +- 0.2 x 10/sup -8/ mole, expired one week after the study. Liver biopsy demonstrated practically no normal tissue. Thus, by means of a complementary, receptor radiopharmaceutical and mathematical model, one should be able to quantitatively follow hepatocyte function and predict response to a therapeutic regimen.« less

  11. Performance of TcI/TcVI/TcII Chagas-Flow ATE-IgG2a for universal and genotype-specific serodiagnosis of Trypanosoma cruzi infection

    PubMed Central

    Alessio, Glaucia Diniz; de Araújo, Fernanda Fortes; Côrtes, Denise Fonseca; Sales Júnior, Policarpo Ademar; Lima, Daniela Cristina; Gomes, Matheus de Souza; do Amaral, Laurence Rodrigues; Xavier, Marcelo Antônio Pascoal; Teixeira-Carvalho, Andréa; Martins-Filho, Olindo Assis; de Lana, Marta

    2017-01-01

    Distinct Trypanosoma cruzi genotypes have been considered relevant for patient management and therapeutic response of Chagas disease. However, typing strategies for genotype-specific serodiagnosis of Chagas disease are still unavailable and requires standardization for practical application. In this study, an innovative TcI/TcVI/TcII Chagas Flow ATE-IgG2a technique was developed with applicability for universal and genotype-specific diagnosis of T. cruzi infection. For this purpose, the reactivity of serum samples (percentage of positive fluorescent parasites-PPFP) obtained from mice chronically infected with TcI/Colombiana, TcVI/CL or TcII/Y strain as well as non-infected controls were determined using amastigote-AMA, trypomastigote-TRYPO and epimastigote-EPI in parallel batches of TcI, TcVI and TcII target antigens. Data demonstrated that “α-TcII-TRYPO/1:500, cut-off/PPFP = 20%” presented an excellent performance for universal diagnosis of T. cruzi infection (AUC = 1.0, Se and Sp = 100%). The combined set of attributes “α-TcI-TRYPO/1:4,000, cut-off/PPFP = 50%”, “α-TcII-AMA/1:1,000, cut-off/PPFP = 40%” and “α-TcVI-EPI/1:1,000, cut-off/PPFP = 45%” showed good performance to segregate infections with TcI/Colombiana, TcVI/CL or TcII/Y strain. Overall, hosts infected with TcI/Colombiana and TcII/Y strains displayed opposite patterns of reactivity with “α-TcI TRYPO” and “α-TcII AMA”. Hosts infected with TcVI/CL strain showed a typical interweaved distribution pattern. The method presented a good performance for genotype-specific diagnosis, with global accuracy of 69% when the population/prototype scenario include TcI, TcVI and TcII infections and 94% when comprise only TcI and TcII infections. This study also proposes a receiver operating reactivity panel, providing a feasible tool to classify serum samples from hosts infected with distinct T. cruzi genotypes, supporting the potential of this method for universal and genotype

  12. Synthesis and characterization of fac-Re(CO)3-aspartic-N-monoacetic acid, a structural analogue of a potential new renal tracer, fac-99mTc(CO)3(ASMA).

    PubMed

    Klenc, Jeffrey; Lipowska, Malgorzata; Taylor, Andrew T; Marzilli, Luigi G

    2012-09-01

    The reaction of an aminopolycarboxylate ligand, as partic- N - m onoacetic a cid (ASMA), with [Re(CO) 3 (H 2 O) 3 ] + was examined. The tridentate coordination of ASMA to this Re I tricarbonyl precursor yielded fac -Re(CO) 3 (ASMA) as a mixture of diastereomers. The chemistry is analogous to that of the Tc I tricarbonyl complex, which yields fac - 99m Tc(CO) 3 (ASMA) under similar conditions. The formation, structure, and isomerization of fac -Re(CO) 3 (ASMA) products were characterized by HPLC, 1 H NMR spectroscopy, and X-ray crystallography. The two major fac -Re(CO) 3 (ASMA) diastereomeric products each have a linear ONO coordination mode with two adjacent five-membered chelate rings, but they differ in the endo or exo orientation of the uncoordinated acetate group, in agreement with expectations based on previous studies. Conditions have been identified for the expedient isomerization of fac -Re(CO) 3 (ASMA) to a mixture consisting primarily of one major product. Because different isomeric species typically have different pharmacokinetic characteristics, these conditions may provide for the practical isolation of a single 99m Tc(CO) 3 (ASMA) species, thus allowing the isolation of the isomer that has optimal imaging and pharmacokinetic characteristics. This information will aid in the design of future 99m Tc radiopharmaceuticals.

  13. Synthesis and characterization of fac-Re(CO)3-aspartic-N-monoacetic acid, a structural analogue of a potential new renal tracer, fac-99mTc(CO)3(ASMA)

    PubMed Central

    Klenc, Jeffrey; Lipowska, Malgorzata; Taylor, Andrew T.; Marzilli, Luigi G.

    2013-01-01

    The reaction of an aminopolycarboxylate ligand, aspartic-N-monoacetic acid (ASMA), with [Re(CO)3(H2O)3]+ was examined. The tridentate coordination of ASMA to this ReI tricarbonyl precursor yielded fac-Re(CO)3(ASMA) as a mixture of diastereomers. The chemistry is analogous to that of the TcI tricarbonyl complex, which yields fac-99mTc(CO)3(ASMA) under similar conditions. The formation, structure, and isomerization of fac-Re(CO)3(ASMA) products were characterized by HPLC, 1H NMR spectroscopy, and X-ray crystallography. The two major fac-Re(CO)3(ASMA) diastereomeric products each have a linear ONO coordination mode with two adjacent five-membered chelate rings, but they differ in the endo or exo orientation of the uncoordinated acetate group, in agreement with expectations based on previous studies. Conditions have been identified for the expedient isomerization of fac-Re(CO)3(ASMA) to a mixture consisting primarily of one major product. Because different isomeric species typically have different pharmacokinetic characteristics, these conditions may provide for the practical isolation of a single 99mTc(CO)3(ASMA) species, thus allowing the isolation of the isomer that has optimal imaging and pharmacokinetic characteristics. This information will aid in the design of future 99mTc radiopharmaceuticals. PMID:24273448

  14. Theoretical Modeling of 99 Tc NMR Chemical Shifts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hall, Gabriel B.; Andersen, Amity; Washton, Nancy M.

    Technetium (Tc) displays a rich chemistry due to the wide range of oxidation states (from -I to +VII) and ability to form coordination compounds. Determination of Tc speciation in complex mixtures is a major challenge, and 99Tc NMR spec-troscopy is widely used to probe chemical environments of Tc in odd oxidation states. However interpretation of the 99Tc NMR data is hindered by the lack of reference compounds. DFT computations can help fill this gap, but to date few com-putational studies have focused on 99Tc NMR of compounds and complexes. This work systematically evaluates the inclu-sion small percentages of Hartree-Fock exchangemore » correlation and relativistic effects in DFT computations to support in-terpretation of the 99Tc NMR spectra. Hybrid functionals are found to perform better than their pure GGA counterparts, and non-relativistic calculations have been found to generally show a lower mean absolute deviation from experiment. Overall non-relativistic PBE0 and B3PW91 calculations are found to most accurately predict 99Tc NMR chemical shifts.« less

  15. Development and Pharmacological Evaluation of New Bone-Targeted (99m)Tc-Radiolabeled Bisphosphonates.

    PubMed

    Makris, George; Tseligka, Eirini D; Pirmettis, Ioannis; Papadopoulos, Minas S; Vizirianakis, Ioannis S; Papagiannopoulou, Dionysia

    2016-07-05

    A novel bisphosphonate, 1-(3-aminopropylamino)ethane-1,1-diyldiphosphonic acid (3), was coupled to the tridentate chelators di-2-picolylamine, 2-picolylamine-N-acetic acid, iminodiacetic acid, 3-((2-aminoethyl)thio)-3-(1H-imidazol-4-yl)propanoic acid, and 2-((2-carboxyethyl)thio)-3-(1H-imidazol-4-yl)propanoic acid to form ligands 6, 9, 11, 15, and 19, respectively. Organometallic complexes of the general formula [Re/(99m)Tc(CO)3(κ(3)-L)] were synthesized, where L denotes ligand 6, 9, 11, 15, or 19. The rhenium complexes were prepared at the macroscopic level and characterized by spectroscopic methods. The technetium-99m organometallic complexes were synthesized in high yield and were identified by comparative reversed-phase HPLC with their Re analogues. The (99m)Tc tracers were stable in vitro and exhibited binding to hydroxyapatite. In biodistribution studies, all of the (99m)Tc complexes exhibited high bone uptake superior to that of 25, which is the directly (99m)Tc-labeled bisphosphonate 3, and comparable to that of (99m)Tc-methylene diphosphonate ((99m)Tc-MDP). The tracers [(99m)Tc(CO)3(6)] (26), [(99m)Tc(CO)3(9)] (27), [(99m)Tc(CO)3(11)] (28), and [(99m)Tc(CO)3(15)] (29) exhibited higher bone/blood ratios than (99m)Tc-MDP. 26 had the highest bone uptake at 1 h p.i. The new bisphosphonates showed no substantial growth inhibitory capacity in PC-3, Saos-2, and MCF-7 established cancer cell lines at low concentrations. Incubation of 26 with the same cancer cell lines indicated a rapid and saturated uptake. The promising properties of 26-29 indicate their potential for use as bone-imaging agents.

  16. MagLifter Site Investigation and Implementation Strategies

    NASA Technical Reports Server (NTRS)

    Burke, Pamela; Slaughter, Maynard; Beer, C. Neil

    1995-01-01

    MagLifter, as defined here, is an advanced, earth-bound catapult system to provide the initial lift for earth orbiting vehicles to reduce or eliminate the need for multistage propulsion, thus reducing the cost of orbital space flight. It is presumed that magnetic levitation will catapult the vehicle to a desired initial velocity sufficient for reaching orbit with the vehicles own engines. Of necessity, the system must be located on and around a mountain with sufficient relief to allow the catapult to accelerate the launch vehicle to a sufficient speed in the desired direction to allow it to reach orbit. Such a mountain site must meet criteria consistent with current and future space launch needs and conditions. It is the purpose of this report to set forth preliminary criteria for choosing a suitable maglifter site. The report is divided into four major sections: (1) Assumed Launch System and Flight Vehicle Characteristics; (2) Task 1.A - Initial Site Selection Criteria; (3) Conclusions; and (4) Appendix - Phases of the Site Selection Process.

  17. Superconductivity in semimetallic B i 3 O 2 S 3

    DOE PAGES

    Li, L.; Parker, D.; Babkevich, P.; ...

    2015-03-12

    We report in this paper a further investigation on the thermodynamic and transport properties, and an assessment of theoretical calculations, for the BiS 2-layered Bi 3O 2S 3 superconductor. The polycrystalline sample is synthesized with a superconducting transition temperature of T c onset=5.75K and T c zero=4.03K (≈Tc mag) that drops to 3.3 K by applying a hydrostatic pressure of 6 kbar. Density-of-states (DOS) calculations give substantial hybridization between Bi, O, and S, with Bi the largest component of DOS, which supports the idea that the BiS 2 layer is relevant for producing electron-phonon coupling. An analysis of previously publishedmore » specific heat data for Bi 3O 2S 3 is additionally suggestive of a strong electron-phonon interaction in the Bi-O-S system. The analysis of the Seebeck coefficient results strongly suggests that Bi 3O 2S 3 is a semimetal. In fact, we found the semimetallic or narrow band gap behavior may occur in certain other materials in the BiS 2-layered class of materials, such as Bi 4O 4S 3.« less

  18. Development of a Luminex Bead Based Assay for Diagnosis of Toxocariasis Using Recombinant Antigens Tc-CTL-1 and Tc-TES-26.

    PubMed

    Anderson, John P; Rascoe, Lisa N; Levert, Keith; Chastain, Holly M; Reed, Matthew S; Rivera, Hilda N; McAuliffe, Isabel; Zhan, Bin; Wiegand, Ryan E; Hotez, Peter J; Wilkins, Patricia P; Pohl, Jan; Handali, Sukwan

    2015-01-01

    The clinical spectrum of human disease caused by the roundworms Toxocara canis and Toxocara cati ranges from visceral and ocular larva migrans to covert toxocariasis. The parasite is not typically recovered in affected tissues, so detection of parasite-specific antibodies is usually necessary for establishing a diagnosis. The most reliable immunodiagnostic methods use the Toxocara excretory-secretory antigens (TES-Ag) in ELISA formats to detect Toxocara-specific antibodies. To eliminate the need for native parasite materials, we identified and purified immunodiagnostic antigens using 2D gel electrophoresis followed by electrospray ionization mass spectrometry. Three predominant immunoreactive proteins were found in the TES; all three had been previously described in the literature: Tc-CTL-1, Tc-TES-26, and Tc-MUC-3. We generated Escherichia coli expressed recombinant proteins for evaluation in Luminex based immunoassays. We were unable to produce a functional assay with the Tc-MUC-3 recombinant protein. Tc-CTL-1 and Tc-TES-26 were successfully coupled and tested using defined serum batteries. The use of both proteins together generated better results than if the proteins were used individually. The sensitivity and specificity of the assay for detecting visceral larval migrans using Tc-CTL-1 plus Tc-TES-26 was 99% and 94%, respectively; the sensitivity for detecting ocular larval migrans was 64%. The combined performance of the new assay was superior to the currently available EIA and could potentially be employed to replace current assays that rely on native TES-Ag.

  19. Development of a Luminex Bead Based Assay for Diagnosis of Toxocariasis Using Recombinant Antigens Tc-CTL-1 and Tc-TES-26

    PubMed Central

    Anderson, John P.; Rascoe, Lisa N.; Levert, Keith; Chastain, Holly M.; Reed, Matthew S.; Rivera, Hilda N.; McAuliffe, Isabel; Zhan, Bin; Wiegand, Ryan E.; Hotez, Peter J.; Wilkins, Patricia P.; Pohl, Jan; Handali, Sukwan

    2015-01-01

    The clinical spectrum of human disease caused by the roundworms Toxocara canis and Toxocara cati ranges from visceral and ocular larva migrans to covert toxocariasis. The parasite is not typically recovered in affected tissues, so detection of parasite-specific antibodies is usually necessary for establishing a diagnosis. The most reliable immunodiagnostic methods use the Toxocara excretory-secretory antigens (TES-Ag) in ELISA formats to detect Toxocara-specific antibodies. To eliminate the need for native parasite materials, we identified and purified immunodiagnostic antigens using 2D gel electrophoresis followed by electrospray ionization mass spectrometry. Three predominant immunoreactive proteins were found in the TES; all three had been previously described in the literature: Tc-CTL-1, Tc-TES-26, and Tc-MUC-3. We generated Escherichia coli expressed recombinant proteins for evaluation in Luminex based immunoassays. We were unable to produce a functional assay with the Tc-MUC-3 recombinant protein. Tc-CTL-1 and Tc-TES-26 were successfully coupled and tested using defined serum batteries. The use of both proteins together generated better results than if the proteins were used individually. The sensitivity and specificity of the assay for detecting visceral larval migrans using Tc-CTL-1 plus Tc-TES-26 was 99% and 94%, respectively; the sensitivity for detecting ocular larval migrans was 64%. The combined performance of the new assay was superior to the currently available EIA and could potentially be employed to replace current assays that rely on native TES-Ag. PMID:26485145

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thorstad, B.L.; Russell, C.D.; Dubovsky, E.V.

    A case of renovascular hypertension is presented in which the (/sup 131/I)hippuran renogram was initially normal, but became strikingly abnormal upon administration of the angiotensin converting enzyme (ACE) inhibitor captopril. The patient presented with fibromuscular dysplasia of the renal arteries, which was shown by hippuran renography to be functionally significant on the right side. She became normotensive after angioplasty of the right renal artery. Hypertension recurred a year later, at which time the renogram was normal without captopril, but showed functionally significant left renal artery stenosis with captopril challenge. Both the conventional agent, (/sup 131/I)hippuran, and an experimental new /supmore » 99m/Tc-labeled hippuran analog, (/sup 99m/Tc)MAG3, were used. Angiography confirmed progression of disease on the left side, which was successfully treated by angioplasty. Functionally significant unilateral renal artery stenosis was thus demonstrated first on the right side and then, 1 yr later, on the left side, using hippuran and (/sup 99m/Tc)MAG3. Anatomic progression of disease was documented by angiography.« less

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dormehl, I.C.; Van Wyk, A.; Pilloy, W.

    In light of the high price of commercially available mercaptoacetyltriglycene (MAG3) it was decided to attempt a local MAG3-formation and to test this against diethylenetriamine pentaacetic acid (DTPA), /sup 123/I-Hippuran, and commercial MAG3 for diagnostic radiorenographic capabilities also in conjunction with furosemide and captopril. A baboon model (n = 6) was used, and the parameters evaluated were obtained by the integral spleen method of radiorenogram analysis. Although the images and parameters pointed to /sup 123/I-Hippuran and commercial MAG3 as the ideal renal scanning agents and to DTPA as the least so, with the local product an acceptable alternative, the differencesmore » were not significant enough to warrant either the purchase of the commercial product or the extensive development of the local product. Inexpensive /sup 99m/Tc-DTPA in conjunction with modern computer techniques will probably supply most of the answers.« less

  2. Into the blue: AO science with MagAO in the visible

    NASA Astrophysics Data System (ADS)

    Close, Laird M.; Males, Jared R.; Follette, Katherine B.; Hinz, Phil; Morzinski, Katie; Wu, Ya-Lin; Kopon, Derek; Riccardi, Armando; Esposito, Simone; Puglisi, Alfio; Pinna, Enrico; Xompero, Marco; Briguglio, Runa; Quiros-Pacheco, Fernando

    2014-08-01

    We review astronomical results in the visible (λ<1μm) with adaptive optics. Other than a brief period in the early 1990s, there has been little astronomical science done in the visible with AO until recently. The most productive visible AO system to date is our 6.5m Magellan telescope AO system (MagAO). MagAO is an advanced Adaptive Secondary system at the Magellan 6.5m in Chile. This secondary has 585 actuators with < 1 msec response times (0.7 ms typically). We use a pyramid wavefront sensor. The relatively small actuator pitch (~23 cm/subap) allows moderate Strehls to be obtained in the visible (0.63-1.05 microns). We use a CCD AO science camera called "VisAO". On-sky long exposures (60s) achieve <30mas resolutions, 30% Strehls at 0.62 microns (r') with the VisAO camera in 0.5" seeing with bright R < 8 mag stars. These relatively high visible wavelength Strehls are made possible by our powerful combination of a next generation ASM and a Pyramid WFS with 378 controlled modes and 1000 Hz loop frequency. We'll review the key steps to having good performance in the visible and review the exciting new AO visible science opportunities and refereed publications in both broad-band (r,i,z,Y) and at Halpha for exoplanets, protoplanetary disks, young stars, and emission line jets. These examples highlight the power of visible AO to probe circumstellar regions/spatial resolutions that would otherwise require much larger diameter telescopes with classical infrared AO cameras.

  3. Impeding 99Tc(IV) mobility in novel waste forms

    DOE PAGES

    Lee, Mal-Soon; Um, Wooyong; Wang, Guohui; ...

    2016-06-30

    Technetium ( 99Tc) is a long-lived radioactive fission product whose mobility in the subsurface is largely governed by its oxidation state1. Immobilization of Tc in mineral substrates is crucial for radioactive waste management and environmental remediation. Tc(IV) incorporation in spinels2, 3 has been proposed as a novel method to increase Tc retention in glass waste forms. However, experiments with Tc-magnetite under high temperature and oxic conditions showed re-oxidation of Tc(IV) to volatile pertechnetate Tc(VII)O4-.4, 5 Here we address this problem with large-scale ab initio molecular dynamics simulations and propose that elevated temperatures, 1st row transition metal dopants can significantly enhancemore » Tc retention in the order Co > Zn > Ni. Experiments with doped spinels at T=700 ºC provided quantitative confirmation of increased Tc retention in the same order predicted by theory. This work highlights the power of modern state-of-the-art simulations to provide essential insights and generate bottom-up design criteria of complex oxide materials at elevated temperatures.« less

  4. Biokinetics and dosimetry in patients of 99mTc-EDDA/HYNIC-Tyr3-octreotide prepared from lyophilized kits.

    PubMed

    González-Vázquez, Armando; Ferro-Flores, Guillermina; Arteaga de Murphy, Consuelo; Gutiérrez-García, Zohar

    2006-07-01

    99mTc-EDDA/HYNIC-Tyr3-octreotide (99mTc-HYNIC-TOC) has shown high in vitro and in vivo stability, rapid background clearance and rapid detection of somatostatin receptor-positive tumors. The aim of this study was to establish a biokinetic model for 99mTc-HYNIC-TOC prepared from lyophilized kits, and to evaluate its dosimetry as a tumor imaging agent in patients with histologically confirmed neuroendocrine tumors. Whole-body images from eight patients were acquired at 5, 60, 90, 180 min and 24 h after 99mTc-HYNIC-TOC administration obtained from instant freeze-dried kit formulations with radiochemical purities >95%. Regions of interest (ROIs) were drawn around source organs on each time frame. The same set of ROIs was used for all eight scans and the count per minute (cpm) of each ROI was converted to activity using the conjugate view counting method. The image sequence was used to extrapolate 99mTc-HYNIC-TOC time-activity curves in each organ, to adjust a biokinetic model using the SAAM software, and to calculate the total number of disintegrations (N) that occurred in the source regions. N data were the input for the OLINDA/EXM code to calculate internal radiation dose estimates. Images showed an average tumor/blood (heart) ratio of 4.3+/-0.7 in receptor-positive tumors at 1 h. The mean radiation absorbed dose calculated for a study using 740 MBq was 24, 21.5, 5.5 and 1.0 mSv for spleen, kidneys, liver and bone marrow respectively and the effective dose was 4.4 mSv.

  5. Tc17 cells in patients with uterine cervical cancer.

    PubMed

    Zhang, Yan; Hou, Fei; Liu, Xin; Ma, Daoxin; Zhang, Youzhong; Kong, Beihua; Cui, Baoxia

    2014-01-01

    The existence of Tc17 cells was recently shown in several types of infectious and autoimmune diseases, but their distribution and functions in uterine cervical cancer (UCC) have not been fully elucidated. The frequency of Tc17 cells in peripheral blood samples obtained from UCC patients, cervical intraepithelial neoplasia (CIN) patients and healthy controls was determined by flow cytometry. Besides, the prevalence of Tc17 cells and their relationships to Th17 cells and Foxp3-expressing T cells as well as microvessels in tissue samples of the patients were assessed by immunohistochemistry staining. Compared to controls, patients with UCC or CIN had a higher proportion of Tc17 cells in both peripheral blood and cervical tissues, but the level of Tc17 cells in UCC tissues was significantly higher than that in CIN tissues. Besides, the increased level of Tc17 in UCC patients was associated with the status of pelvic lymph node metastases and increased microvessel density. Finally, significant correlations of infiltration between Tc17 cells and Th17 cells or Foxp3-expressing T cells were observed in UCC and CIN tissues. This study indicates that Tc17 cell infiltration in cervical cancers is associated with cancer progression accompanied by increased infiltrations of Th17 cells and regulatory T cells as well as promoted tumor vasculogenesis.

  6. Tc17 Cells in Patients with Uterine Cervical Cancer

    PubMed Central

    Zhang, Yan; Hou, Fei; Liu, Xin; Ma, Daoxin; Zhang, Youzhong; Kong, Beihua; Cui, Baoxia

    2014-01-01

    Background The existence of Tc17 cells was recently shown in several types of infectious and autoimmune diseases, but their distribution and functions in uterine cervical cancer (UCC) have not been fully elucidated. Methods The frequency of Tc17 cells in peripheral blood samples obtained from UCC patients, cervical intraepithelial neoplasia (CIN) patients and healthy controls was determined by flow cytometry. Besides, the prevalence of Tc17 cells and their relationships to Th17 cells and Foxp3-expressing T cells as well as microvessels in tissue samples of the patients were assessed by immunohistochemistry staining. Results Compared to controls, patients with UCC or CIN had a higher proportion of Tc17 cells in both peripheral blood and cervical tissues, but the level of Tc17 cells in UCC tissues was significantly higher than that in CIN tissues. Besides, the increased level of Tc17 in UCC patients was associated with the status of pelvic lymph node metastases and increased microvessel density. Finally, significant correlations of infiltration between Tc17 cells and Th17 cells or Foxp3-expressing T cells were observed in UCC and CIN tissues. Conclusions This study indicates that Tc17 cell infiltration in cervical cancers is associated with cancer progression accompanied by increased infiltrations of Th17 cells and regulatory T cells as well as promoted tumor vasculogenesis. PMID:24523865

  7. Mechanical performance comparison between RotaFlow and CentriMag centrifugal blood pumps in an adult ECLS model.

    PubMed

    Yulong Guan; Xiaowei Su; McCoach, Robert; Kunselman, Allen; El-Banayosy, Aly; Undar, Akif

    2010-03-01

    Centrifugal blood pumps have been widely adopted in conventional adult cardiopulmonary bypass and circulatory assist procedures. Different brands of centrifugal blood pumps incorporate distinct designs which affect pump performance. In this adult extracorporeal life support (ECLS) model, the performances of two brands of centrifugal blood pump (RotaFlow blood pump and CentriMag blood pump) were compared. The simulated adult ECLS circuit used in this study included a centrifugal blood pump, Quadrox D membrane oxygenator and Sorin adult ECLS tubing package. A Sorin Cardiovascular(R) VVR(R) 4000i venous reservoir (Sorin S.p.A., Milan, Italy) with a Hoffman clamp served as a pseudo-patient. The circuit was primed with 900ml heparinized human packed red blood cells and 300ml lactated Ringer's solution (total volume 1200 ml, corrected hematocrit 40%). Trials were conducted at normothermia (36 degrees C). Performance, including circuit pressure and flow rate, was measured for every setting analyzed. The shut-off pressure of the RotaFlow was higher than the CentriMag at all measurement points given the same rotation speed (p < 0.0001). The shut-off pressure differential between the two centrifugal blood pumps was significant and increased given higher rotation speeds (p < 0.0001). The RotaFlow blood pump has higher maximal flow rate (9.08 +/- 0.01L/min) compared with the CentriMag blood pump (8.37 +/- 0.02L/min) (p < 0.0001). The blood flow rate differential between the two pumps when measured at the same revolutions per minute (RPM) ranged from 1.64L/min to 1.73L/min. The results obtained in this experiment demonstrate that the RotaFlow has a higher shut-off pressure (less retrograde flow) and maximal blood flow rate than the CentriMag blood pump. Findings support the conclusion that the RotaFlow disposable pump head has a better mechanical performance than the CentriMag. In addition, the RotaFlow disposable pump is 20-30 times less expensive than the CentriMag.

  8. 99m Tc-HYNIC-(Ser)3 -J18 peptide: A radiotracer for non-small-cell lung cancer targeting.

    PubMed

    Shaghaghi, Zahra; Abedi, Seyed Mohammad; Hosseinimehr, Seyed Jalal

    2018-02-14

    Radiolabeled peptide could be a useful tool for the diagnosis of non-small-cell lung cancer (NSCLC). In this study, HYNIC-(Ser) 3 -J18 peptide was labeled with 99m Tc using EDDA/tricine as coligands. The in vitro and in vivo studies of this radiolabeled peptide were performed for cellular-specific binding and tumor targeting in A-549 cells and tumor-bearing mice, respectively. The high radiochemical purity was obtained and this radiolabeled peptide exhibited high stability in buffer and serum. The radiolabeled peptide showed high affinity for the A-549 cells with a dissociation constant value (K D ) of 4.4 ± 0.8 nm. The tumor-muscles ratios were 2.7 and 4.4 at 1 and 2 hr after injection of 99m Tc-(EDDA/tricine)-HYNIC-(Ser) 3 -J18 in tumor-bearing mice. The tumor uptake was decreased after preinjection with non-labeled peptide for this radiolabeled peptide in blocking experiment. The results of this study showed the 99m Tc-(EDDA/tricine)-(Ser) 3 -HYNIC-J18 peptide might be a promising radiolabeled peptide for NSCLC targeting. © 2018 John Wiley & Sons A/S.

  9. Comparison of MagNA Pure 96, Chemagic MSM1, and QIAamp MinElute for hepatitis B virus nucleic acid extraction.

    PubMed

    Kang, Seong-Ho; Lee, Eun Hee; Park, Geon; Jang, Sook Jin; Moon, Dae Soo

    2012-01-01

    This study was designed to compare two automated systems and one manual system for hepatitis B virus (HBV) nucleic acid extraction. The two automated systems were the MagNA Pure 96 system (Roche Applied Science, Manheim, Germany) and the Chemagic system (Chemagen, Baesweiler, Germany), and the manual system was the QIAamp system (Qiagen, Hilden, Germany). Sixty-eight samples that were within the detection range of the Cobas Ampliprep/Cobas TaqMan (CAP/CTM) platform (Roche Molecular Systems, Manheim, Germany) were selected. Extracted viral nucleic acids from the three systems were quantified using an AccuPower HBV Quantitative PCR kit (Bioneer, Daejon, Korea). The MagNA Pure 96 system and QIAamp system did not detect viral loads in one sample. The Chemagic system did not detect low viral loads in nine samples (range, 26-290 IU/mL by the CAP/CTM platform). Comparisons of the viral loads of the samples from the MagNA Pure 96 system, the Chemagic system, and the QIAamp system with those from the CAP/CTM platform yielded correlation coefficients of 0.977, 0.914, and 0.967, respectively. Comparisons of the MagNA Pure 96 system and the Chemagic system with the QIAamp system yielded correlation coefficients of 0.987 and 0.939, respectively. The MagNA Pure 96 system demonstrated better performance than the Chemagic system for HBV nucleic acid extraction. The MagNA Pure 96 system demonstrated comparable performance with the QIAamp system.

  10. Unified electronic phase diagram for hole-doped high- Tc cuprates

    NASA Astrophysics Data System (ADS)

    Honma, T.; Hor, P. H.

    2008-05-01

    We have analyzed various characteristic temperatures and energies of hole-doped high- Tc cuprates as a function of a dimensionless hole-doping concentration (pu) . Entirely based on the experimental grounds, we construct a unified electronic phase diagram (UEPD), where three characteristic temperatures ( T∗ ’s) and their corresponding energies ( E∗ ’s) converge as pu increases in the underdoped regime. T∗ ’s and E∗ ’s merge together with the Tc curve and 3.5kBTc curve at pu˜1.1 in the overdoped regime, respectively. They finally go to zero at pu˜1.3 . The UEPD follows an asymmetric half-dome-shaped Tc curve, in which Tc appears at pu˜0.4 , reaches a maximum at pu˜1 , and rapidly goes to zero at pu˜1.3 . The asymmetric half-dome-shaped Tc curve is at odds with the well-known symmetric superconducting dome for La2-xSrxCuO4 (SrD-La214), in which two characteristic temperatures and energies converge as pu increases and merge together at pu˜1.6 , where Tc goes to zero. The UEPD clearly shows that pseudogap phase precedes and coexists with high temperature superconductivity in the underdoped and overdoped regimes, respectively. It is also clearly seen that the upper limit of high- Tc cuprate physics ends at a hole concentration that equals to 1.3 times the optimal doping concentration for almost all high- Tc cuprate materials and 1.6 times the optimal doping concentration for the SrD-La214. Our analysis strongly suggests that pseudogap is a precursor of high- Tc superconductivity, the observed quantum critical point inside the superconducting dome may be related to the end point of UEPD, and the normal state of the underdoped and overdoped high temperature superconductors cannot be regarded as a conventional Fermi liquid phase.

  11. Hall effect in high- Tc Y 1Ba 2Cu 3O 7-δ superconductor

    NASA Astrophysics Data System (ADS)

    Vezzoli, G. C.; Burke, T.; Moon, B. M.; Lalevic, B.; Safari, A.; Sundar, H. G. K.; Bonometti, R.; Alexander, C.; Rau, C.; Waters, K.

    1989-04-01

    We have performed point-by-point and continuous Hall effect experiments as a function of temperature in polycrystalline Y 1Ba 2Cu 3O 7-δ. We have shown that the positive Hall constant shows an abrupt increase upon decreasing temperature at a value just above Tc. This temperature corresponds to where the resistance versus temperature data deviates from linearity. At very high fields of 6.8 and 15 T we observe a subsequent decrease in RH. We interpret these data as supportive of a contribution toward the superconductivity mechanism arising from internal excitions or change transfer excitations such that the bound exciton concentration increases near Tc at the expense of positive carries which are reflected in both bound and free holes.

  12. Use of Mini-Mag Orion and superconducting coils for near-term interstellar transportation

    NASA Astrophysics Data System (ADS)

    Lenard, Roger X.; Andrews, Dana G.

    2007-06-01

    Interstellar transportation to nearby star systems over periods shorter than the human lifetime requires speeds in the range of 0.1-0.15 c and relatively high accelerations. These speeds are not attainable using rockets, even with advanced fusion engines because at these velocities, the energy density of the spacecraft approaches the energy density of the fuel. Anti-matter engines are theoretically possible but current physical limitations would have to be suspended to get the mass densities required. Interstellar ramjets have not proven practicable, so this leaves beamed momentum propulsion or a continuously fueled Mag-Orion system as the remaining candidates. However, deceleration is also a major issue, but part of the Mini-Mag Orion approach assists in solving this problem. This paper reviews the state of the art from a Phases I and II SBIT between Sandia National Laboratories and Andrews Space, applying our results to near-term interstellar travel. A 1000 T crewed spacecraft and propulsion system dry mass at .1c contains ˜9×1021J. The author has generated technology requirements elsewhere for use of fission power reactors and conventional Brayton cycle machinery to propel a spacecraft using electric propulsion. Here we replace the electric power conversion, radiators, power generators and electric thrusters with a Mini-Mag Orion fission-fusion hybrid. Only a small fraction of fission fuel is actually carried with the spacecraft, the remainder of the propellant (macro-particles of fissionable material with a D-T core) is beamed to the spacecraft, and the total beam energy requirement for an interstellar probe mission is roughly 1020J, which would require the complete fissioning of 1000 ton of Uranium assuming 35% power plant efficiency. This is roughly equivalent to a recurring cost per flight of 3.0 billion dollars in reactor grade enriched uranium using today's prices. Therefore, interstellar flight is an expensive proposition, but not unaffordable, if the

  13. Chemical and biological characterization of technetium(I) and Rhenium(I) tricarbonyl complexes with dithioether ligands serving as linkers for coupling the Tc(CO)(3) and Re(CO)(3) moieties to biologically active molecules.

    PubMed

    Pietzsch, H J; Gupta, A; Reisgys, M; Drews, A; Seifert, S; Syhre, R; Spies, H; Alberto, R; Abram, U; Schubiger, P A; Johannsen, B

    2000-01-01

    The organometallic precursor (NEt(4))(2)[ReBr(3)(CO)(3)] was reacted with bidendate dithioethers (L) of the general formula H(3)C-S-CH(2)CH(2)-S-R (R = -CH(2)CH(2)COOH, CH(2)-C&tbd1;CH) and R'-S-CH(2)CH(2)-S-R' (R' = CH(3)CH(2)-, CH(3)CH(2)-OH, and CH(2)COOH) in methanol to form stable rhenium(I) tricarbonyl complexes of the general composition [ReBr(CO)(3)L]. Under these conditions, the functional groups do not participate in the coordination. As a prototypic representative of this type of Re compounds, the propargylic group bearing complex [ReBr(CO(3))(H(3)C-S-CH(2)CH(2)-S-CH(2)C&tbd1;CH)] Re2 was studied by X-ray diffraction analysis. Its molecular structure exhibits a slightly distorted octahedron with facial coordination of the carbonyl ligands. The potentially tetradentate ligand HO-CH(2)CH(2)-S-CH(2)CH(2)-S-CH(2)CH(2)-OH was reacted with the trinitrato precursor [Re(NO(3))(3)(CO)(3)](2-) to yield a cationic complex [Re(CO)(3)(HO-CH(2)CH(2)-S-CH(2)CH(2)-S-CH(2)CH(2)-OH)]NO(3) Re8 which shows the coordination of one hydroxy group. Re8 has been characterized by correct elemental analysis, infrared spectroscopy, capillary electrophoresis, and X-ray diffraction analysis. Ligand exchange reaction of the carboxylic group bearing ligands H(3)C-S-CH(2)CH(2)-S-CH(2)CH(2)-COOH and HOOC-CH(2)-S-CH(2)CH(2)-S-CH(2)-COOH with (NEt(4))(2)[ReBr(3)(CO)(3)] in water and with equimolar amounts of NaOH led to complexes in which the bromide is replaced by the carboxylic group. The X-ray structure analysis of the complex [Re(CO)(3)(OOC-CH(2)-S-CH(2)CH(2)-S-CH(2)-COOH)] Re6 shows the second carboxylic group noncoordinated offering an ideal site for functionalization or coupling a biomolecule. The no-carrier-added preparation of the analogous (99m)Tc(I) carbonyl thioether complexes could be performed using the precursor fac-[(99m)Tc(H(2)O)(3)(CO)(3)](+), with yields up to 90%. The behavior of the chlorine containing (99m)Tc complex [(99m)TcCl(CO)(3)(CH(3)CH(2)-S-CH(2)CH(2)-S-CH(2)CH

  14. Pressure and high-Tc superconductivity in sulfur hydrides.

    PubMed

    Gor'kov, Lev P; Kresin, Vladimir Z

    2016-05-11

    The paper discusses fundamentals of record-TC superconductivity discovered under high pressure in sulfur hydride. The rapid increase of TC with pressure in the vicinity of Pcr ≈ 123GPa is interpreted as the fingerprint of a first-order structural transition. Based on the cubic symmetry of the high-TC phase, it is argued that the lower-TC phase has a different periodicity, possibly related to an instability with a commensurate structural vector. In addition to the acoustic branches, the phonon spectrum of H3S contains hydrogen modes with much higher frequencies. Because of the complex spectrum, usual methods of calculating TC are here inapplicable. A modified approach is formulated and shown to provide realistic values for TC and to determine the relative contributions of optical and acoustic branches. The isotope effect (change of TC upon Deuterium for Hydrogen substitution) originates from high frequency phonons and differs in the two phases. The decrease of TC following its maximum in the high-TC phase is a sign of intermixing with pairing at hole-like pockets which arise in the energy spectrum of the cubic phase at the structural transition. On-pockets pairing leads to the appearance of a second gap and is remarkable for its non-adiabatic regime: hydrogen mode frequencies are comparable to the Fermi energy.

  15. Neuronal composition of the magnocellular division of the medial preoptic nucleus (MPN mag) is sex specific in the Syrian hamster (Mesocricetus auratus).

    PubMed

    Richendrfer, Holly A; Swann, Jennifer M

    2010-09-10

    The magnocellular division of the medial Preoptic nucleus (MPN mag) plays a critical role in the regulation of male sexual behavior in the hamster. Results from previous studies indicated that the number of neurons in the MPN mag is greater in males than females but failed to find significant differences in the volume of the nucleus suggesting that other elements in the nucleus may be greater in the female. The results of the present study, using NeuN to identify neurons, are in line with this hypothesis. The data show that (1) neurons in the MPN mag display two distinct phenotypes, those with a single nucleolus and those with multiple nucleoli; (2) the percentage of each phenotype is sex specific, differing over the course of development and (3) there is no sex difference in the number of glial cells at any age. Sex differences in the numbers of each type are correlated with developmental milestones and suggest that morphological changes are influenced by changes in circulating gonadal steroids during development. 2010 Elsevier B.V. All rights reserved.

  16. Synthesis of Tc-99m labeled 1,2,3-triazole-4-yl c-met binding peptide as a potential c-met receptor kinase positive tumor imaging agent.

    PubMed

    Kim, Eun-Mi; Joung, Min-Hee; Lee, Chang-Moon; Jeong, Hwan-Jeong; Lim, Seok Tae; Sohn, Myung-Hee; Kim, Dong Wook

    2010-07-15

    The mesenchymal-epithelial transition factor (c-Met), which is related to tumor cell growth, angiogenesis and metastases, is known to be overexpressed in several tumor types. In this study, we synthesized technetium-99m labeled 1,2,3-triazole-4-yl c-Met binding peptide (cMBP) derivatives, prepared by solid phase peptide synthesis and the 'click-to-chelate' protocol for the introduction of tricarbonyl technetium-99m, as a potential c-Met receptor kinase positive tumor imaging agent, and evaluated their in vitro c-Met binding affinity, cellular uptake, and stability. The (99m)Tc labeled cMBP derivatives ([(99m)Tc(CO)(3)]12, [(99m)Tc(CO)(3)]13, and [(99m)Tc(CO)(3)]14) were prepared in 85-90% radiochemical yields. The cold surrogate cMBP derivatives, [Re(CO)(3)]12, [Re(CO)(3)]13, and [Re(CO)(3)]14, were shown to have high binding affinities (0.13 microM, 0.06 microM, and 0.16 microM, respectively) to a purified cMet/Fc chimeric recombinant protein. In addition, the in vitro cellular uptake and inhibition studies demonstrated the high specific binding of these (99m)Tc labeled cMBP derivatives ([(99m)Tc(CO)(3)]12-14) to c-Met receptor positive U87MG cells. 2010 Elsevier Ltd. All rights reserved.

  17. Plasma exchanges for severe acute neurological deterioration in patients with IgM anti-myelin-associated glycoprotein (anti-MAG) neuropathy.

    PubMed

    Baron, M; Lozeron, P; Harel, S; Bengoufa, D; Vignon, M; Asli, B; Malphettes, M; Parquet, N; Brignier, A; Fermand, J P; Kubis, N; Arnulf, Bertrand

    2017-06-01

    Monoclonal IgM anti-myelin-associated glycoprotein (MAG) antibody-related peripheral neuropathy (anti-MAG neuropathy) is predominantly a demyelinating sensory neuropathy with ataxia and distal paresthesia. The clinical course of anti-MAG neuropathy is usually slowly progressive making difficult the identification of clear criteria to start a specific treatment. Although no consensus treatment is yet available, a rituximab-based regimen targeting the B-cell clone producing the monoclonal IgM may be proposed, alone or in combination with alkylating agents or purine analogs. However, in some rare cases, an acute and severe neurological deterioration can occur in few days leading to a rapid loss of autonomy. In these cases, a treatment rapidly removing the monoclonal IgM from the circulation might be useful before initiating a specific therapy. We report successful treatment with plasma exchanges (PE) in four patients presenting with acute neurological deterioration. PE allowed a dramatic and rapid neurological improvement in all patients. PE are safe and may be useful at the initial management of these cases of anti-MAG neuropathy.

  18. A New MIC1-MAG1 Recombinant Chimeric Antigen Can Be Used Instead of the Toxoplasma gondii Lysate Antigen in Serodiagnosis of Human Toxoplasmosis

    PubMed Central

    Holec-Gąsior, Lucyna; Ferra, Bartłomiej; Drapała, Dorota; Lautenbach, Dariusz

    2012-01-01

    This study presents an evaluation of the MIC1 (microneme protein 1)-MAG1 (matrix antigen 1) Toxoplasma gondii recombinant chimeric antigen for the serodiagnosis of human toxoplasmosis for the first time. The recombinant MIC1-MAG1 antigen was obtained as a fusion protein containing His tags at the N- and C-terminal ends using an Escherichia coli expression system. After purification by metal affinity chromatography, the chimeric protein was tested for usefulness in an enzyme-linked immunosorbent assay (ELISA) for the detection of anti-T. gondii immunoglobulin G (IgG). One hundred ten sera from patients at different stages of infection and 40 sera from seronegative patients were examined. The results obtained for the MIC1-MAG1 chimeric antigen were compared with those of IgG ELISAs using a Toxoplasma lysate antigen (TLA), a combination of recombinant antigens (rMIC1ex2-rMAG1) and single recombinant proteins (rMIC1ex2 and rMAG1). The sensitivity of the IgG ELISA calculated from all of the positive serum samples was similar for the MIC1-MAG1 chimeric antigen (90.8%) and the TLA (91.8%), whereas the sensitivities of the other antigenic samples used were definitely lower, at 69.1% for the mixture of antigens, 75.5% for the rMIC1ex2, and 60% for rMAG1. This study demonstrates that the MIC1-MAG1 recombinant chimeric antigen can be used instead of the TLA in the serodiagnosis of human toxoplasmosis. PMID:22116686

  19. An improved 99mTc-HYNIC-(Ser)3-LTVSPWY peptide with EDDA/tricine as co-ligands for targeting and imaging of HER2 overexpression tumor.

    PubMed

    Khodadust, Fatemeh; Ahmadpour, Sajjad; Aligholikhamseh, Nazan; Abedi, Seyed Mohammad; Hosseinimehr, Seyed Jalal

    2018-01-20

    Overexpression of human epidermal receptor 2 (HER2) has given the opportunity for targeting and delivering of imaging radiotracers. The aim of this study was to evaluate the 99m Tc-HYNIC-(EDDA/tricine)-(Ser) 3 -LTVSPWY peptide for tumor targeting and imaging of tumor with overexpression of HER2. The HYNIC-(Ser) 3 -LTVSPWY was labeled with 99m Tc in presence of EDDA/tricine mixture as co-ligands. The in vitro and in vivo studies of this radiolabeled peptide were performed for cellular specific binding and tumor targeting. The high radiochemical purity of 99m Tc-HYNIC (EDDA/tricine)-(Ser) 3 -LTVSPWY was obtained to be 99%. It exhibited high stability in normal saline and human serum. In HER2 binding affinity study, a significant reduction in uptake of radiolabeled peptide (7.7 fold) was observed by blocking SKOV-3 cells receptors with unlabeled peptide. The K D and B max values for this radiolabeled peptide were determined as 3.3 ± 1.0 nM and 2.9 ± 0.3 × 10 6 CPM/pMol, respectively. Biodistribution study revealed tumor to blood and tumor to muscle ratios about 6.9 and 4 respectively after 4 h. Tumor imaging by gamma camera demonstrated considerable high contrast tumor uptake. This developed 99m Tc-HYNIC-(Ser) 3 -LTVSPWY peptide selectively targeted on HER2 tumor and exhibited a high target uptake combined with acceptable low background activity for tumor imaging in mice. The results of this study and its comparison with another study showed that 99m Tc-HYNIC-(EDDA/tricine)-(Ser) 3 -LTVSPWY is much better than previously reported radiolabeled peptide as 99m Tc-CSSS-LTVSPWY for HER2 overexpression tumor targeting and imaging. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  20. Experimental study of {sup 99m}Tc-aluminum oxide use for sentinel lymph nodes detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chernov, V. I., E-mail: Chernov@oncology.tomsk.ru; Sinilkin, I. G.; Zelchan, R. V.

    The purpose of the study was a comparative research in the possibility of using the radiopharmaceuticals {sup 99m}Tc-Al{sub 2}O{sub 3} and {sup 99m}Tc-Nanocis for visualizing sentinel lymph nodes. The measurement of the sizes of {sup 99m}Tc-Al{sub 2}O{sub 3} and {sup 99m}Tc-Nanocis colloidal particles was performed in seven series of radiopharmaceuticals. The pharmacokinetics of {sup 99m}Tc-Al{sub 2}O{sub 3} and {sup 99m}Tc-Nanocis was researched on 50 white male rats. The possibility of the use of {sup 99m}Tc-Al{sub 2}O{sub 3} and {sup 99m}Tc-Nanocis for lymphoscintigraphy was studied in the experiments on 12 white male rats. The average dynamic diameter of the sol particlemore » was 52–77 nm for {sup 99m}Tc-Al{sub 2}O{sub 3} and 16.7–24.5 nm for {sup 99m}Tc-Nanocis. Radiopharmaceuticals accumulated in the inguinal lymph node in 1 hour after administration; the average uptake of {sup 99}mTc-Al{sub 2}O{sub 3} was 8.6% in it, and the accumulation of {sup 99m}Tc-Nanocis was significantly lower—1.8% (p < 0.05). In all study points the average uptake of {sup 99m}Tc-Al{sub 2}O{sub 3} in the lymph node was significantly higher than {sup 99m}Tc-Nanocis accumulation. The results of dynamic scintigraphic studies in rats showed that {sup 99m}Tc-Al{sub 2}O{sub 3} and {sup 99m}Tc-Nanocis actively accumulated into the lymphatic system. By using {sup 99m}Tc-Al{sub 2}O{sub 3} inguinal lymph node was determined in 5 minutes after injection and clearly visualized in all the animals in the 15th minute, when the accumulation became more than 1% of the administered dose. Further observation indicated that the {sup 99m}Tc-Al{sub 2}O{sub 3} accumulation reached a plateau in a lymph node (average 10.5%) during 2-hour study and then its accumulation remained practically at the same level, slightly increasing to 12% in 24 hours. In case of {sup 99m}Tc-Nanocis inguinal lymph node was visualized in all animals for 15 min when it was accumulated on the average 1.03% of the

  1. Impurities in Tc-99m radiopharmaceutical solution obtained from Mo-100 in cyclotron.

    PubMed

    Tymiński, Zbigniew; Saganowski, Paweł; Kołakowska, Ewa; Listkowska, Anna; Ziemek, Tomasz; Cacko, Daniel; Dziel, Tomasz

    2018-04-01

    The gamma emitting impurities in 99m Tc solution obtained from enriched molybdenum 100 Mo metallic target after its irradiation in a cyclotron were measured using a high-purity germanium (HPGe) detector. The radioactivity range of tested samples of 99m Tc was rather low, in the range from 0.34 to 2.39 MBq, thus creating a challenge to investigate the standard measurement HPGe system for impurity detection and quantification. In the process of 99m Tc separation from irradiated target the AnaLig® Tc-02 resin, Dionex H + and Alumina A columns were used. Fractions of eluates from various steps of separation process were taken and measured for radionuclidic purity. The overall measurement sensitivity of gamma emitters in terms of minimum detectable activity (MDA) was found at the level of 14-70Bq with emission lines in range of 36 - 1836keV resulting in impurity content range of 6.7 × 10 -4 to 3.4 × 10 -3 % for 93 Tc, 93m Tc, 94 Tc, 94m Tc, 95 Tc, 95m Tc, 96 Tc 96 Nb, 97 Nb, 99 Mo contaminants and 9.4 × 10 -3 % for 97m Tc. The usefulness of the chosen measurement conditions and the method applied to testing the potential contaminators was proved by reaching satisfactory results of MDAs less than the criteria of impurity concentration of all nuclides specified in the European Pharmacopoeia. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Asteroid 2008 TC3 Breakup and Meteorite Fractions

    NASA Technical Reports Server (NTRS)

    Goodrich, C.; Jenniskens, P.; Shaddad, M. H.; Zolensky, M. E.; Fioretti, A. M.

    2017-01-01

    The recovery of meteorites from the impact of asteroid 2008 TC3 in the Nubian Desert of Sudan on October 7, 2008, marked the first time meteorites were collected from an asteroid observed in space by astronomical techniques before impacting. Search teams from the University of Khartoum traced the location of the strewn field and collected about 660 meteorites in four expeditions to the fall region, all of which have known fall coordinates. Upon further study, the Almahata Sitta meteorites proved to be a mixed bag of mostly ureilites (course grained, fine grained, and sulfide-metal assemblages), enstatite chondrites (EL3-6, EH3, EH5, breccias) and ordinary chondrites (H5-6, L4-5). One bencubbinite-like carbonaceous chondrite was identified, as well as one unique Rumuruti-like chondrite and an Enstatite achondrite. New analysis: The analysed meteorites so far suggest a high 30-40 percent fraction of non-ureilites among the recovered samples, but that high fraction does not appear to be in agreement with the meteorites in the University of Khartoum (UoK) collection. Ureilites dominate the meteorites that were recovered by the Sudanese teams. To better understand the fraction of recovered materials that fell to Earth, a program has been initiated to type the meteorites in the UoK collection in defined search areas. At this meeting, we will present some preliminary results from that investigation.

  3. Introducing a New Interface for the Online MagIC Database by Integrating Data Uploading, Searching, and Visualization

    NASA Astrophysics Data System (ADS)

    Jarboe, N.; Minnett, R.; Constable, C.; Koppers, A. A.; Tauxe, L.

    2013-12-01

    The Magnetics Information Consortium (MagIC) is dedicated to supporting the paleomagnetic, geomagnetic, and rock magnetic communities through the development and maintenance of an online database (http://earthref.org/MAGIC/), data upload and quality control, searches, data downloads, and visualization tools. While MagIC has completed importing some of the IAGA paleomagnetic databases (TRANS, PINT, PSVRL, GPMDB) and continues to import others (ARCHEO, MAGST and SECVR), further individual data uploading from the community contributes a wealth of easily-accessible rich datasets. Previously uploading of data to the MagIC database required the use of an Excel spreadsheet using either a Mac or PC. The new method of uploading data utilizes an HTML 5 web interface where the only computer requirement is a modern browser. This web interface will highlight all errors discovered in the dataset at once instead of the iterative error checking process found in the previous Excel spreadsheet data checker. As a web service, the community will always have easy access to the most up-to-date and bug free version of the data upload software. The filtering search mechanism of the MagIC database has been changed to a more intuitive system where the data from each contribution is displayed in tables similar to how the data is uploaded (http://earthref.org/MAGIC/search/). Searches themselves can be saved as a permanent URL, if desired. The saved search URL could then be used as a citation in a publication. When appropriate, plots (equal area, Zijderveld, ARAI, demagnetization, etc.) are associated with the data to give the user a quicker understanding of the underlying dataset. The MagIC database will continue to evolve to meet the needs of the paleomagnetic, geomagnetic, and rock magnetic communities.

  4. Comparative evaluation of [(99m)tc]tilmanocept for sentinel lymph node mapping in breast cancer patients: results of two phase 3 trials.

    PubMed

    Wallace, Anne M; Han, Linda K; Povoski, Stephen P; Deck, Kenneth; Schneebaum, Schlomo; Hall, Nathan C; Hoh, Carl K; Limmer, Karl K; Krontiras, Helen; Frazier, Thomas G; Cox, Charles; Avisar, Eli; Faries, Mark; King, Dennis W; Christman, Lori; Vera, David R

    2013-08-01

    Sentinel lymph node (SLN) surgery is used worldwide for staging breast cancer patients and helps limit axillary lymph node dissection. [(99m)Tc]Tilmanocept is a novel receptor-targeted radiopharmaceutical evaluated in 2 open-label, nonrandomized, within-patient, phase 3 trials designed to assess the lymphatic mapping performance. A total of 13 centers contributed 148 patients with breast cancer. Each patient received [(99m)Tc]tilmanocept and vital blue dye (VBD). Lymph nodes identified intraoperatively as radioactive and/or blue stained were excised and histologically examined. The primary endpoint, concordance (lower boundary set point at 90 %), was the proportion of nodes detected by VBD and [(99m)Tc]tilmanocept. A total of 13 centers contributed 148 patients who were injected with both agents. Intraoperatively, 207 of 209 nodes detected by VBD were also detected by [(99m)Tc]tilmanocept for a concordance rate of 99.04 % (p < 0.0001). [(99m)Tc]tilmanocept detected a total of 320 nodes, of which 207 (64.7 %) were detected by VBD. [(99m)Tc]Tilmanocept detected at least 1 SLN in more patients (146) than did VBD (131, p < 0.0001). In 129 of 131 patients with ≥1 blue node, all blue nodes were radioactive. Of 33 pathology-positive nodes (18.2 % patient pathology rate), [(99m)Tc]tilmanocept detected 31 of 33, whereas VBD detected only 25 of 33 (p = 0.0312). No pathology-positive SLNs were detected exclusively by VBD. No serious adverse events were attributed to [(99m)Tc]tilmanocept. [(99m)Tc]Tilmanocept demonstrated success in detecting a SLN while meeting the primary endpoint. Interestingly, [(99m)Tc]tilmanocept was additionally noted to identify more SLNs in more patients. This localization represented a higher number of metastatic breast cancer lymph nodes than that of VBD.

  5. The impact and recovery of asteroid 2008 TC(3).

    PubMed

    Jenniskens, P; Shaddad, M H; Numan, D; Elsir, S; Kudoda, A M; Zolensky, M E; Le, L; Robinson, G A; Friedrich, J M; Rumble, D; Steele, A; Chesley, S R; Fitzsimmons, A; Duddy, S; Hsieh, H H; Ramsay, G; Brown, P G; Edwards, W N; Tagliaferri, E; Boslough, M B; Spalding, R E; Dantowitz, R; Kozubal, M; Pravec, P; Borovicka, J; Charvat, Z; Vaubaillon, J; Kuiper, J; Albers, J; Bishop, J L; Mancinelli, R L; Sandford, S A; Milam, S N; Nuevo, M; Worden, S P

    2009-03-26

    In the absence of a firm link between individual meteorites and their asteroidal parent bodies, asteroids are typically characterized only by their light reflection properties, and grouped accordingly into classes. On 6 October 2008, a small asteroid was discovered with a flat reflectance spectrum in the 554-995 nm wavelength range, and designated 2008 TC(3) (refs 4-6). It subsequently hit the Earth. Because it exploded at 37 km altitude, no macroscopic fragments were expected to survive. Here we report that a dedicated search along the approach trajectory recovered 47 meteorites, fragments of a single body named Almahata Sitta, with a total mass of 3.95 kg. Analysis of one of these meteorites shows it to be an achondrite, a polymict ureilite, anomalous in its class: ultra-fine-grained and porous, with large carbonaceous grains. The combined asteroid and meteorite reflectance spectra identify the asteroid as F class, now firmly linked to dark carbon-rich anomalous ureilites, a material so fragile it was not previously represented in meteorite collections.

  6. Preparation and evaluation of 99mTc-EDDA/HYNIC-[Lys 3]-bombesin for imaging gastrin-releasing peptide receptor-positive tumours.

    PubMed

    Ferro-Flores, Guillermina; Arteaga de Murphy, Consuelo; Rodriguez-Cortés, Jeanette; Pedraza-López, Martha; Ramírez-Iglesias, María Teresa

    2006-04-01

    Bombesin is a peptide that was initially isolated from frog skin and which belongs to a large group of neuropeptides with many biological functions. The human equivalent is gastrin-releasing peptide (GRP), whose receptors are over-expressed in a variety of malignant tumours. To prepare a HYNIC-[Lys 3]-bombesin analogue that could be easily labelled with 99mTc from lyophilized kit formulations and to evaluate its potential as an imaging agent for GRP receptor-positive tumours. HYNIC was conjugated to the epsilon-amino group of Lys 3 residue at the N-terminal region of bombesin via succinimidyl-N-Boc-HYNIC at pH 9.0. 99mTc labelling was performed by addition of sodium pertechnetate solution and 0.2 M phosphate buffer pH 7.0 to a lyophilized formulation. Stability studies were carried out by reversed phase HPLC and ITLC-SG analyses in serum and cysteine solutions. In-vitro internalization was tested using human prostate cancer PC-3 cells with blocked and non-blocked receptors. Biodistribution and tumour uptake were determined in PC-3 tumour-bearing nude mice. 99mTc-EDDA/HYNIC-[Lys 3]-bombesin was obtained with radiochemical purities >93% and high specific activity ( approximately 0.1 GBq.nmol). Results of in-vitro studies demonstrated a high stability in serum and cysteine solutions, specific cell receptor binding and rapid internalization. Biodistribution data showed a rapid blood clearance, with predominantly renal excretion and specific binding towards GRP receptor-positive tissues such as pancreas and PC-3 tumours. 99mTc-EDDA/HYNIC-[Lys 3]-bombesin obtained from lyophilized kit formulations has promising characteristics for the diagnosis of malignant tumours that over-express the GRP receptor.

  7. New Gastrin Releasing Peptide Receptor-Directed [99mTc]Demobesin 1 Mimics: Synthesis and Comparative Evaluation.

    PubMed

    Nock, Berthold A; Charalambidis, David; Sallegger, Werner; Waser, Beatrice; Mansi, Rosalba; Nicolas, Guillaume P; Ketani, Eleni; Nikolopoulou, Anastasia; Fani, Melpomeni; Reubi, Jean-Claude; Maina, Theodosia

    2018-04-12

    We have previously reported on the gastrin releasing peptide receptor (GRPR) antagonist [ 99m Tc]1, ([ 99m Tc]demobesin 1, 99m Tc-[N 4 '-diglycolate-dPhe 6 ,Leu-NHEt 13 ]BBN(6-13)). [ 99m Tc]1 has shown superior biological profile compared to analogous agonist-based 99m Tc-radioligands. We herein present a small library of [ 99m Tc]1 mimics generated after structural modifications in (a) the linker ([ 99m Tc]2, [ 99m Tc]3, [ 99m Tc]4), (b) the peptide chain ([ 99m Tc]5, [ 99m Tc]6), and (c) the C-terminus ([ 99m Tc]7 or [ 99m Tc]8). The effects of above modifications on the biological properties of analogs were studied in PC-3 cells and tumor-bearing SCID mice. All analogs showed subnanomolar affinity for the human GRPR, while most receptor-affine 4 and 8 behaved as potent GRPR antagonists in a functional internalization assay. In mice bearing PC-3 tumors, [ 99m Tc]1-[ 99m Tc]6 exhibited GRPR-specific tumor uptake, rapidly clearing from normal tissues. [ 99m Tc]4 displayed the highest tumor uptake (28.8 ± 4.1%ID/g at 1 h pi), which remained high even after 24 h pi (16.3 ± 1.8%ID/g), well surpassing that of [ 99m Tc]1 (5.4 ± 0.7%ID/g at 24 h pi).

  8. Spectroscopic Properties of Tc(I) Tricarbonyl Species Relevant to the Hanford Tank Waste

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Levitskaia, Tatiana G.; Andersen, Amity; Chatterjee, Sayandev

    2015-12-04

    Technetium-99 (Tc) exists predominately in soluble forms in the liquid supernatant and salt cake fractions of the nuclear tank waste stored at the U.S. DOE Hanford Site. In the strongly alkaline environments prevalent in the tank waste, its dominant chemical form is pertechnetate (TcO4-, oxidation state +7). However, attempts to remove Tc from the Hanford tank waste using ion-exchange processes specific to TcO 4 - only met with limited success, particularly processing tank waste samples containing elevated concentrations of organic complexants. This suggests that a significant fraction of the soluble Tc can be present as non-pertechnetate low-valent Tc (oxidation statemore » < +7) (non-pertechnetate). The chemical identities of these non-pertechnetate species are poorly understood. Previous analysis of the SY-101 and SY-103 tank waste samples provided strong evidence that non-pertechnetate can be comprised of [Tc(CO) 3] + complexes containing Tc in oxidation state +1 (Lukens et al. 2004). During the last two years, our team has expanded this work and demonstrated that high-ionic-strength solutions typifying tank waste supernatants promote oxidative stability of the [Tc(CO) 3] + species (Rapko et al. 2013; Levitskaia et al. 2014). It also was observed that high-ionic-strength alkaline matrices stabilize Tc(VI) and potentially Tc(IV) oxidation states, particularly in presence organic chelators, suggesting that the relevant Tc compounds can serve as important redox intermediates facilitating the reduction of Tc(VII) to Tc(I). Designing strategies for effective Tc processing, including separation and immobilization, necessitates understanding the molecular structure of these non-pertechnetate species and their identification in the actual tank waste samples. To-date, only limited information exists regarding the nature and characterization of the Tc(I), Tc(IV), and Tc(VI) species. One objective of this project is to identify the form of non-pertechnetate in the

  9. Correlation between superfluid density and T(C) of underdoped YBa2Cu3O6+x near the superconductor-insulator transition.

    PubMed

    Zuev, Yuri; Kim, Mun Seog; Lemberger, Thomas R

    2005-09-23

    We report measurements of the ab-plane superfluid density n(s) (magnetic penetration depth lambda) of heavily underdoped films of YBa2Cu3O6+x, with T(C)'s from 6 to 50 K. We find the characteristic length for vortex unbinding transition equal to the film thickness, suggesting strongly coupled CuO2 layers. At the lowest dopings, T(C) is as much as 5 times larger than the upper limit set by the 2D Kosterlitz-Thouless-Berezinskii transition temperature calculated for individual CuO2 bilayers. Our main finding is that T(C) is not proportional to n(s)(0); instead, we find T(C) proportional to ns(1/2.3+/-0.4). This conflicts with a popular point of view that quasi-2D thermal phase fluctuations determine the transition temperature.

  10. The assessment of renal cortex and parenchymal volume using automated CT volumetry for predicting renal function after donor nephrectomy.

    PubMed

    Mitsui, Yosuke; Sadahira, Takuya; Araki, Motoo; Wada, Koichiro; Tanimoto, Ryuta; Ariyoshi, Yuichi; Kobayashi, Yasuyuki; Watanabe, Masami; Watanabe, Toyohiko; Nasu, Yasutomo

    2018-04-01

    Contrast-enhanced CT is necessary before donor nephrectomy and is usually combined with a Tc-99m-mercapto-acetyltriglycine (MAG3) scan to check split renal function (SRF). However, all transplant programs do not use MAG3 because of its high cost and exposure to radiation. We examined whether CT volumetry of the kidney can be a new tool for evaluating SRF. Sixty-three patients underwent live donor nephrectomy. Patients without a 1.0 mm slice CT or follow-up for <12 months were excluded leaving 34 patients' data being analyzed. SRF was measured by MAG3. Split renal volume (SRV) was calculated automatically using volume analyzer software. The correlation between SRF and SRV was examined. The association between the donor's postoperative estimated glomerular filtration rate (eGFR) and predicted eGFR calculated by MAG3 or CT volumetry was analyzed at 1, 3, and 12 months post nephrectomy. Strong correlations were observed preoperatively in a Bland-Altman plot between SRF measured by MAG3 and either CT cortex or parenchymal volumetry. In addition, eGFR after donation correlated with SRF measured by MAG3 or CT volumetry. The correlation coefficients (R) for eGFR Mag3 split were 0.755, 0.615, and 0.763 at 1, 3 and 12 months, respectively. The corresponding R values for cortex volume split were 0.679, 0.638, and 0.747. Those for parenchymal volume split were 0.806, 0.592, and 0.764. Measuring kidney by CT volumetry is a cost-effective alternative to MAG3 for evaluating SRF and predicting postoperative donor renal function. Both cortex and parenchymal volumetry were similarly effective.

  11. Coordination modes of multidentate ligands in fac-[Re(CO)(3)(polyaminocarboxylate)] analogues of (99m)Tc radiopharmaceuticals. dependence on aqueous solution reaction conditions.

    PubMed

    Lipowska, Malgorzata; He, Haiyang; Xu, Xiaolong; Taylor, Andrew T; Marzilli, Patricia A; Marzilli, Luigi G

    2010-04-05

    We study Re analogues of (99m)Tc renal agents to interpret previous results at the (99m)Tc tracer level. The relative propensities of amine donors versus carboxylate oxygen donors of four L = polyaminocarboxylate ligands to coordinate in fac-[Re(I)(CO)(3)L](n) complexes were assessed by examining the reaction of fac-[Re(I)(CO)(3)(H(2)O)(3)](+) under conditions differing in acidity and temperature. All four L [N,N-bis-(2-aminoethyl)glycine (DTGH), N,N-ethylenediaminediacetic acid, diethylenetriamine-N-malonic acid, and diethylenetriamine-N-acetic acid] can coordinate as tridentate ligands while creating a dangling chain terminated in a carboxyl group. Dangling carboxyl groups facilitate renal clearance in fac-[(99m)Tc(I)(CO)(3)L](n) agents. Under neutral conditions, the four ligands each gave two fac-[Re(I)(CO)(3)L](n) products with HPLC traces correlating well with known traces of the fac-[(99m)Tc(I)(CO)(3)L](n) mixtures. Such mixtures are common in renal agents because the needed dangling carboxyl group can compete for a coordination site. However, the HPLC separations needed to assess the biodistribution of a single tracer are impractical in a clinical setting. One goal in investigating this Re chemistry is to identify conditions for avoiding this problem of mixtures in preparations of fac-[(99m)Tc(I)(CO)(3)L](n) renal tracers. After separation and isolation of the fac-[Re(I)(CO)(3)L](n) products, NMR analysis of all products and single crystal X-ray crystallographic analysis of both DTGH products, as well as one product each from the other L, allowed us to establish coordination mode unambiguously. The product favored in acidic conditions has a dangling amine chain and more bound oxygen. The product favored in basic conditions has a dangling carboxyl chain and more bound nitrogen. At the elevated temperatures used for simulating tracer preparation, equilibration was facile (ca. 1 h or less), allowing selective formation of one product by utilizing acidic or

  12. Ibogaine labeling with 99mTc-tricarbonyl: synthesis and transport at the mouse blood-brain barrier.

    PubMed

    Tournier, Nicolas; André, Pascal; Blondeel, Sandy; Rizzo-Padoin, Nathalie; du Moulinet d'Hardemarre, Amaury; Declèves, Xavier; Scherrmann, Jean-Michel; Cisternino, Salvatore

    2009-12-01

    The (99m)Tc-tricarbonyl core may be used as an ideal tool for gamma-labeling ligands in noninvasive SPECT imaging. However, most (99m)Tc-tricarbonyl-labeled agents have difficulty crossing the blood-brain barrier (BBB). We radiolabeled the neuroactive indole ibogaine with (99m)Tc-tricarbonyl and measured its transport into the mouse brain by in situ brain perfusion. We measured the interactions of [(99m)Tc(CO)(3)-ibogaine](+) and (99m)Tc-tricarbonyl with the main BBB efflux transporters P-gp and BCRP in vitro and in vivo. Ibogaine was radiolabeled (yield: over 95%). [(99m)Tc(CO)(3)-ibogaine](+) entered the brain (K(in)) poorly (0.18 microL/g/s), at about the same rate as (99m)Tc-tricarbonyl (0.16 microL/g/s) and [(99m)Tc-sestamibi](+) (0.10 microL/g/s). The CNS tracer [(99m)Tc-HMPAO](0) entered the brain approximately 70-times higher than [(99m)Tc(CO)(3)-ibogaine](+). In vitro studies revealed that neither [(99m)Tc(CO)(3)-ibogaine](+) nor (99m)Tc-tricarbonyl ion were substrates for P-gp or BCRP. But lowering the membrane dipole potential barrier with phloretin enhanced the brain transport of [(99m)Tc(OH(2))(3)(CO)(3)](+) approximately 3-fold. Thus, ibogaine directly labeled with (99m)Tc-tricarbonyl is not suitable for CNS imaging because of its poor uptake. Brain transport is not restricted by efflux transporters but is reduced by its lipophilicity and interaction with the membrane-positive dipole potential. 2009 Wiley-Liss, Inc. and the American Pharmacists Association

  13. Synthesis, characterization and biological evaluation of a novel "3 + 1" mixed ligand 99mTc complex having an aliphatic thiol as coligand.

    PubMed

    Rey, A; Papadopoulos, M; Leon, E; Mallo, L; Pirmettis, Y; Manta, E; Raptopoulou, C; Chiotellis, E; Leon, A

    2001-03-01

    A novel "3 + 1" mixed ligand 99mTc complex with N,N-bis(2-mercaptoethyl)-N'N'-diethyl-ethilenediamine as ligand and 1-octanethiol as coligand was prepared and evaluated as potential brain radiopharmaceutical. Preparation at tracer level was accomplished by substitution, using 99mTc-glucoheptonate as precursor and a coligand/ligand ratio of 5. Under these conditions the labeling yield was over 80% and a major product with radiochemical purity >80% was isolated by HPLC methods and used for biological evaluation. Chemical characterization at carrier level was developed using the corresponding rhenium and 99gTc complexes. Results were consistent with the expected "3 + 1" structure and X-ray diffraction study demonstrated that the complex adopted a distorted trigonal bipyramidal geometry. All sulphur atoms underwent ionization leading to the formation of a neutral compound. Biodistribution in mice demonstrated early brain uptake, fast blood clearance and excretion through hepatobiliary system. Although brain/blood ratio increased significantly with time, this novel 99mTc complex did not exhibit ideal properties as brain perfusion radiopharmaceutical since brain uptake was too low.

  14. Origin and history of ureilitic material in the solar system: The view from asteroid 2008 TC3 and the Almahata Sitta meteorite

    NASA Astrophysics Data System (ADS)

    Goodrich, Cyrena Anne; Hartmann, William K.; O'Brien, David P.; Weidenschilling, Stuart J.; Wilson, Lionel; Michel, Patrick; Jutzi, Martin

    2015-04-01

    Asteroid 2008 TC3 (approximately 4 m diameter) was tracked and studied in space for approximately 19 h before it impacted Earth's atmosphere, shattering at 44-36 km altitude. The recovered samples (>680 individual rocks) comprise the meteorite Almahata Sitta (AhS). Approximately 50-70% of these are ureilites (ultramafic achondrites). The rest are chondrites, mainly enstatite, ordinary, and Rumuruti types. The goal of this work is to understand how fragments of so many different types of parent bodies became mixed in the same asteroid. Almahata Sitta has been classified as a polymict ureilite with an anomalously high component of foreign clasts. However, we calculate that the mass of fallen material was ≤0.1% of the pre-atmospheric mass of the asteroid. Based on published data for the reflectance spectrum of the asteroid and laboratory spectra of the samples, we infer that the lost material was mostly ureilitic. Therefore, 2008 TC3 probably contained only a few percent nonureilitic materials, similar to other polymict ureilites except less well consolidated. From available data for the AhS meteorite fragments, we conclude that 2008 TC3 samples essentially the same range of types of ureilitic and nonureilitic materials as other polymict ureilites. We therefore suggest that the immediate parent of 2008 TC3 was the immediate parent of all ureilitic material sampled on Earth. We trace critical stages in the evolution of that material through solar system history. Based on various types of new modeling and re-evaluation of published data, we propose the following scenario. (1) The ureilite parent body (UPB) accreted 0.5-0.6 Ma after formation of calcium-aluminum-rich inclusions (CAI), beyond the ice line (outer asteroid belt). Differentiation began approximately 1 Ma after CAI. (2) The UPB was catastrophically disrupted by a major impact approximately 5 Ma after CAI, with selective subsets of the fragments reassembling into daughter bodies. (3) Either the UPB (before

  15. Technetium-99m mercaptoacetyltriglycine clearance: reference values for infants and children.

    PubMed

    Schofer, O; König, G; Bartels, U; Bockisch, A; Piepenburg, R; Beetz, R; Meyer, G; Hahn, K

    1995-11-01

    Six hundred and thirty-nine clearance studies performed in children aged 7 days to 19 years utilizing technetium-99m mercaptoacetyltriglycine (MAG 3) were retrospectively analysed. Standardized conditions for the investigation included: parenteral hydration (60 ml/hxm2 body surface) in addition to normal oral fluid intake, weight-related dose of 99mTc-MAG 3 (1 MBq/kg body weight, minimum 15 MBq) and calculation of clearance according to Bubeck et al. Of the 513 children, 169 included in this analysis could be classified as "normal" with regard to their renal function. Normal kidney function was judged by the following criteria: normal GFR for age, normal tubular function (absence of proteinuria and glucosuria), normal renal parenchyma (on ultrasonography, MAG 3 scan and intravenous pyelography), absence of significant obstruction and gross reflux (>grade I), no single kidney and no difference in split renal function >20%. Results showed increasing MAG 3 clearance values for infants during the first months of life, reaching the normal range for older children and adults between 7 and 12 months.

  16. Synchrotron X-ray Diffraction and High-Pressure Electrical Resistivity Studies for High-Tc Candidate Nd3.5Sm0.5Ni3O8

    NASA Astrophysics Data System (ADS)

    Uehara, Masatomo; Kobayashi, Kai; Yamamoto, Hiroki; Nakata, Akitoshi; Wakiya, Kazuhei; Umehara, Izuru; Gouchi, Jun; Uwatoko, Yoshiya

    2017-11-01

    Ln4Ni3O8 (Ln = La, Nd, Sm) has attracted much attention as a candidate for high-Tc superconductor due to its close structural and electrical similarities with high-Tc cuprates. However, Ln4Ni3O8 is not a superconductor and shows semiconducting behavior. Our recent work has revealed that Nd3.5Sm0.5Ni3O8 displays metallic behavior down to 20-40 K upon intercalation and subsequent deintercalation treatments with sulfur, followed by a weak semiconducting tendency at lower temperatures. A synchrotron X-ray diffraction experiment suggests that the structural change induced by sulfur treatment can be explained electrostatically by the removal of additional apical oxygen. High-pressure electrical resistivity measurements up to 8 GPa on a metallic sample show the enhancement of the semiconducting tendency at low temperatures, suggesting that the removal of additional apical oxygen is not totally completed under the present conditions of sulfur treatment.

  17. Effective visualization of suppressed thyroid tissue by means of baseline 99mTc-methoxy isobutyl isonitrile in comparison with 99mTc-pertechnetate scintigraphy after TSH stimulation.

    PubMed

    Vattimo, A; Bertelli, P; Burroni, L

    1992-01-01

    Baseline 99mTc-MIBI thyroid scintigraphy was compared with 99mTc-pertechnetate scintigraphy after TSH stimulation in seven patients with suppressed thyroid tissue due to an autonomously functioning thyroid nodule (AFTN). In all patients the suppressed thyroid tissue was visualized by means of both baseline 99mTc-MIBI and post-TSH 99mTc-pertechnetate scintigraphy, and in some cases the former technique provided better visualization. In one patient presenting a "warm" nodule T3-suppression did not affect the nodular/extranodular uptake ratio of 99mTc-MIBI, whereas the 99mTc-pertechnetate uptake ratio increased significantly. This leads us to hypothesize that the thyroid uptake of 99mTc-MIBI is not related to TSH control, but rather to other mechanisms such as the blood flow. Since exogenous TSH is no longer available, 99mTc-MIBI scintigraphy can be successfully used in the place of repeated 99mTc-pertechnetate scintigraphy after TSH stimulation in the assessment of AFTN.

  18. The Magnetics Information Consortium (MagIC) Online Database: Uploading, Searching and Visualizing Paleomagnetic and Rock Magnetic Data

    NASA Astrophysics Data System (ADS)

    Minnett, R.; Koppers, A.; Tauxe, L.; Constable, C.; Pisarevsky, S. A.; Jackson, M.; Solheid, P.; Banerjee, S.; Johnson, C.

    2006-12-01

    The Magnetics Information Consortium (MagIC) is commissioned to implement and maintain an online portal to a relational database populated by both rock and paleomagnetic data. The goal of MagIC is to archive all measurements and the derived properties for studies of paleomagnetic directions (inclination, declination) and intensities, and for rock magnetic experiments (hysteresis, remanence, susceptibility, anisotropy). MagIC is hosted under EarthRef.org at http://earthref.org/MAGIC/ and has two search nodes, one for paleomagnetism and one for rock magnetism. Both nodes provide query building based on location, reference, methods applied, material type and geological age, as well as a visual map interface to browse and select locations. The query result set is displayed in a digestible tabular format allowing the user to descend through hierarchical levels such as from locations to sites, samples, specimens, and measurements. At each stage, the result set can be saved and, if supported by the data, can be visualized by plotting global location maps, equal area plots, or typical Zijderveld, hysteresis, and various magnetization and remanence diagrams. User contributions to the MagIC database are critical to achieving a useful research tool. We have developed a standard data and metadata template (Version 2.1) that can be used to format and upload all data at the time of publication in Earth Science journals. Software tools are provided to facilitate population of these templates within Microsoft Excel. These tools allow for the import/export of text files and provide advanced functionality to manage and edit the data, and to perform various internal checks to maintain data integrity and prepare for uploading. The MagIC Contribution Wizard at http://earthref.org/MAGIC/upload.htm executes the upload and takes only a few minutes to process several thousand data records. The standardized MagIC template files are stored in the digital archives of EarthRef.org where they

  19. The Magnetics Information Consortium (MagIC) Online Database: Uploading, Searching and Visualizing Paleomagnetic and Rock Magnetic Data

    NASA Astrophysics Data System (ADS)

    Koppers, A.; Tauxe, L.; Constable, C.; Pisarevsky, S.; Jackson, M.; Solheid, P.; Banerjee, S.; Johnson, C.; Genevey, A.; Delaney, R.; Baker, P.; Sbarbori, E.

    2005-12-01

    The Magnetics Information Consortium (MagIC) operates an online relational database including both rock and paleomagnetic data. The goal of MagIC is to store all measurements and their derived properties for studies of paleomagnetic directions (inclination, declination) and their intensities, and for rock magnetic experiments (hysteresis, remanence, susceptibility, anisotropy). MagIC is hosted under EarthRef.org at http://earthref.org/MAGIC/ and has two search nodes, one for paleomagnetism and one for rock magnetism. These nodes provide basic search capabilities based on location, reference, methods applied, material type and geological age, while allowing the user to drill down from sites all the way to the measurements. At each stage, the data can be saved and, if the available data supports it, the data can be visualized by plotting equal area plots, VGP location maps or typical Zijderveld, hysteresis, FORC, and various magnetization and remanence diagrams. All plots are made in SVG (scalable vector graphics) and thus can be saved and easily read into the user's favorite graphics programs without loss of resolution. User contributions to the MagIC database are critical to achieve a useful research tool. We have developed a standard data and metadata template (version 1.6) that can be used to format and upload all data at the time of publication in Earth Science journals. Software tools are provided to facilitate easy population of these templates within Microsoft Excel. These tools allow for the import/export of text files and they provide advanced functionality to manage/edit the data, and to perform various internal checks to high grade the data and to make them ready for uploading. The uploading is all done online by using the MagIC Contribution Wizard at http://earthref.org/MAGIC/upload.htm that takes only a few minutes to process a contribution of approximately 5,000 data records. After uploading these standardized MagIC template files will be stored in the

  20. Metabolism of sn-1(3)-Monoacylglycerol and sn-2-Monoacylglycerol in Caecal Enterocytes and Hepatocytes of Brown Trout (Salmo trutta).

    PubMed

    Li, Keshuai; Olsen, Rolf Erik

    2017-01-01

    sn-2-Monoacylglycerol (2-MAG) and sn-1(3)-monoacylglycerol [1(3)-MAG] are important but yet little studied intermediates in lipid metabolism. The current study compared the metabolic fate of 2-MAG and 1(3)-MAG in isolated caecal enterocytes and hepatocytes of brown trout (Salmo trutta). 1(3)-Oleoyl [9,10-3H(N)]-glycerol and 2-Oleoyl [9,10-3H(N)]-glycerol were prepared by pancreatic lipase digestion of triolein [9,10-3H(N)]. The 1(3)-MAG and 2-MAG were efficiently absorbed by enterocytes and hepatocytes at similar rates. The 2-MAG was quickly resynthesized into TAG through the monoacylglycerol acyltransferase (EC: 2.3.1.22, MGAT) pathway in both tissues, whereas 1(3)-MAG was processed into TAG and phospholipids at a much slower rate, suggesting 2-MAG was the preferred substrates for MGAT. Further analysis showed that 1(3)-MAG was synthesized into 1,3-DAG, but there were no accumulation of 1,3-DAG in either enterocytes or hepatocytes, which contrasts that of mammalian studies. Some of the 1(3)-MAG may be acylated to 1,2(2,3)-DAG and then utilized for TAG synthesis. Alternatively, 1(3)-MAG can be hydrolyzed to free fatty acid and glycerol, and re-synthesized into TAG through the glycerol-3-phosphate (Gro-3-P) pathway. The overall data suggested that the limiting step of the intracellular 1(3)-MAG metabolism is the conversion of 1(3)-MAG itself.

  1. Diffraction-limited Visible Light Images of Orion Trapezium Cluster with the Magellan Adaptive Secondary Adaptive Optics System (MagAO)

    NASA Astrophysics Data System (ADS)

    Close, L. M.; Males, J. R.; Morzinski, K.; Kopon, D.; Follette, K.; Rodigas, T. J.; Hinz, P.; Wu, Y.-L.; Puglisi, A.; Esposito, S.; Riccardi, A.; Pinna, E.; Xompero, M.; Briguglio, R.; Uomoto, A.; Hare, T.

    2013-09-01

    We utilized the new high-order (250-378 mode) Magellan Adaptive Optics system (MagAO) to obtain very high spatial resolution observations in "visible light" with MagAO's VisAO CCD camera. In the good-median seeing conditions of Magellan (0.''5-0.''7), we find MagAO delivers individual short exposure images as good as 19 mas optical resolution. Due to telescope vibrations, long exposure (60 s) r' (0.63 μm) images are slightly coarser at FWHM = 23-29 mas (Strehl ~28%) with bright (R < 9 mag) guide stars. These are the highest resolution filled-aperture images published to date. Images of the young (~1 Myr) Orion Trapezium θ1 Ori A, B, and C cluster members were obtained with VisAO. In particular, the 32 mas binary θ1 Ori C 1 C 2 was easily resolved in non-interferometric images for the first time. The relative positions of the bright trapezium binary stars were measured with ~0.6-5 mas accuracy. We are now sensitive to relative proper motions of just ~0.2 mas yr-1 (~0.4 km s-1 at 414 pc)—this is a ~2-10 × improvement in orbital velocity accuracy compared to previous efforts. For the first time, we see clear motion of the barycenter of θ1 Ori B 2 B 3 about θ1 Ori B 1. All five members of the θ1 Ori B system appear likely to be a gravitationally bound "mini cluster," but we find that not all the orbits can be both circular and co-planar. The lowest mass member of the θ1 Ori B system (B 4; mass ~0.2 M ⊙) has a very clearly detected motion (at 4.1 ± 1.3 km s-1 correlation = 99.9%) w.r.t. B 1. Previous work has suggested that B 4 and B 3 are on long-term unstable orbits and will be ejected from this "mini cluster." However, our new "baseline" model of the θ1 Ori B system suggests a more hierarchical system than previously thought, and so the ejection of B 4 may not occur for many orbits, and B 3 may be stable against ejection in the long-term. This "ejection" process of the lowest mass member of a "mini cluster" could play a major role in the formation of

  2. DIFFRACTION-LIMITED VISIBLE LIGHT IMAGES OF ORION TRAPEZIUM CLUSTER WITH THE MAGELLAN ADAPTIVE SECONDARY ADAPTIVE OPTICS SYSTEM (MagAO)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Close, L. M.; Males, J. R.; Morzinski, K.

    2013-09-10

    We utilized the new high-order (250-378 mode) Magellan Adaptive Optics system (MagAO) to obtain very high spatial resolution observations in ''visible light'' with MagAO's VisAO CCD camera. In the good-median seeing conditions of Magellan (0.''5-0.''7), we find MagAO delivers individual short exposure images as good as 19 mas optical resolution. Due to telescope vibrations, long exposure (60 s) r' (0.63 {mu}m) images are slightly coarser at FWHM = 23-29 mas (Strehl {approx}28%) with bright (R < 9 mag) guide stars. These are the highest resolution filled-aperture images published to date. Images of the young ({approx}1 Myr) Orion Trapezium {theta}{sup 1}more » Ori A, B, and C cluster members were obtained with VisAO. In particular, the 32 mas binary {theta}{sup 1} Ori C{sub 1} C{sub 2} was easily resolved in non-interferometric images for the first time. The relative positions of the bright trapezium binary stars were measured with {approx}0.6-5 mas accuracy. We are now sensitive to relative proper motions of just {approx}0.2 mas yr{sup -1} ({approx}0.4 km s{sup -1} at 414 pc)-this is a {approx}2-10 Multiplication-Sign improvement in orbital velocity accuracy compared to previous efforts. For the first time, we see clear motion of the barycenter of {theta}{sup 1} Ori B{sub 2} B{sub 3} about {theta}{sup 1} Ori B{sub 1}. All five members of the {theta}{sup 1} Ori B system appear likely to be a gravitationally bound ''mini cluster'', but we find that not all the orbits can be both circular and co-planar. The lowest mass member of the {theta}{sup 1} Ori B system (B{sub 4}; mass {approx}0.2 M{sub Sun }) has a very clearly detected motion (at 4.1 {+-} 1.3 km s{sup -1}; correlation = 99.9%) w.r.t. B{sub 1}. Previous work has suggested that B{sub 4} and B{sub 3} are on long-term unstable orbits and will be ejected from this ''mini cluster''. However, our new ''baseline'' model of the {theta}{sup 1} Ori B system suggests a more hierarchical system than previously thought

  3. 99mTc-EDDA/HYNIC-octreotate scintigraphy, an efficient method for the detection and staging of carcinoid tumours: results of 3 years' experience.

    PubMed

    Hubalewska-Dydejczyk, A; Fröss-Baron, K; Mikołajczak, R; Maecke, H R; Huszno, B; Pach, D; Sowa-Staszczak, A; Janota, B; Szybiński, P; Kulig, J

    2006-10-01

    At all stages of the disease, serious difficulties are encountered in the imaging diagnosis of carcinoids. Somatostatin receptor scintigraphy (SRS) holds great promise for detecting primary tumours and metastases. 99mTc-EDDA/HYNIC-octreotate should significantly improve the diagnosis of carcinoids in comparison with 111In-Octreoscan owing to the better affinity for SSR2 and the higher count rate. The aim of this study was to assess the diagnostic efficiency of 99mTc-EDDA/HYNIC-octreotate scintigraphy in the detection and staging of carcinoid tumours. The study population comprised 75 patients (age 48.5+/-15.5 years): 46 with histological confirmation of carcinoid and 29 with suspected disease. 99mTc-EDDA/HYNIC-octreotate (740 MBq) SRS and CT were performed in all patients. Fifteen patients were examined with 111In-Octreoscan. High-quality 99mTc-EDDA/HYNIC-octreotate images were obtained in all cases, with maximum tumour tracer accumulation 4 h p.i. The mean target/non-target ratios for whole body (WB) and SPECT scans were, respectively, as follows: primary lesions: 4.5 and 10.2; metastases: liver, 3.1 and 12.3; abdominal focal lesions, 2.7 and 5.8; lung, 2.7 and 8.3; mediastinum, 3.4 and 7.6; bones, 6.8 and 19.0. 99mTc-EDDA/HYNIC-octreotate WB scans revealed more metastases than 111In-Octreoscan, with better individual separation. 99mTc-EDDA/HYNIC-octreotate SRS revealed new metastatic lesions in seven patients with confirmed carcinoid, and in four with dissemination the primary focus was found. Five patients qualified for radioguided surgery and 11 were referred to 90Y-DOTA-TATE therapy. The sensitivity of SRS in comparison with CT was higher for primary lesions and liver and abdominal lymph node metastases. In the subgroup of patients with suspected neuroendocrine tumours, two duodenal carcinoids, one thymic carcinoid and one ileal carcinoid were found. 99mTc-EDDA/HYNIC-octreotate, with high imaging quality, is an excellent alternative to 111In-Octreoscan for

  4. Laser heating challenges of high yield MagLIF targets

    NASA Astrophysics Data System (ADS)

    Slutz, Stephen; Sefkow, Adam; Vesey, Roger

    2014-10-01

    The MagLIF (Magnetized Liner Inertial Fusion) concept is predicted by numerical simulation to produce fusion yields of about 100 kJ, when driven by 25 MA from the existing Z accelerator [S. A. Slutz et al. Phys. Plasmas 17, 056303 (2010)] and much higher yields with future accelerators delivering higher currents [Slutz and Vesey PRL 108, 025003 (2012)]. The fuel must be heated before compression to obtain significant fusion yields due to the relatively slow implosion velocities (~ 100 km/s) of magnetically driven liners. Lasers provide a convenient means to accomplish this pre-compressional heating of the fusion fuel, but there are challenges. The laser must penetrate a foil covering the laser entrance hole and deposit 20-30 kJ within the ~1 cm length of the liner in fuel at 6-12 mg/cc. Such high densities could result in beam scattering due to refraction and laser plasma interactions. Numerical simulations of the laser heating process are presented, which indicate that energies as high as 30 kJ could be deposited in the fuel by using two laser pulses of different wavelengths. Simulations of this process will be presented as well of results for a MagLIF design for a potential new machine delivering 50 MA of current. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy's National Nuclear Security Administration under Contract DE-AC04-94AL85000.

  5. Creating a FIESTA (Framework for Integrated Earth Science and Technology Applications) with MagIC

    NASA Astrophysics Data System (ADS)

    Minnett, R.; Koppers, A. A. P.; Jarboe, N.; Tauxe, L.; Constable, C.

    2017-12-01

    The Magnetics Information Consortium (https://earthref.org/MagIC) has recently developed a containerized web application to considerably reduce the friction in contributing, exploring and combining valuable and complex datasets for the paleo-, geo- and rock magnetic scientific community. The data produced in this scientific domain are inherently hierarchical and the communities evolving approaches to this scientific workflow, from sampling to taking measurements to multiple levels of interpretations, require a large and flexible data model to adequately annotate the results and ensure reproducibility. Historically, contributing such detail in a consistent format has been prohibitively time consuming and often resulted in only publishing the highly derived interpretations. The new open-source (https://github.com/earthref/MagIC) application provides a flexible upload tool integrated with the data model to easily create a validated contribution and a powerful search interface for discovering datasets and combining them to enable transformative science. MagIC is hosted at EarthRef.org along with several interdisciplinary geoscience databases. A FIESTA (Framework for Integrated Earth Science and Technology Applications) is being created by generalizing MagIC's web application for reuse in other domains. The application relies on a single configuration document that describes the routing, data model, component settings and external services integrations. The container hosts an isomorphic Meteor JavaScript application, MongoDB database and ElasticSearch search engine. Multiple containers can be configured as microservices to serve portions of the application or rely on externally hosted MongoDB, ElasticSearch, or third-party services to efficiently scale computational demands. FIESTA is particularly well suited for many Earth Science disciplines with its flexible data model, mapping, account management, upload tool to private workspaces, reference metadata, image

  6. [Comparison of manual and automated (MagNA Pure) nucleic acid isolation methods in molecular diagnosis of HIV infections].

    PubMed

    Alp, Alpaslan; Us, Dürdal; Hasçelik, Gülşen

    2004-01-01

    Rapid quantitative molecular methods are very important for the diagnosis of human immunodeficiency virus (HIV) infections, assessment of prognosis and follow up. The purpose of this study was to compare and evaluate the performances of conventional manual extraction method and automated MagNA Pure system, for the nucleic acid isolation step which is the first and most important step in molecular diagnosis of HIV infections. Plasma samples of 35 patients in which anti-HIV antibodies were found as positive by microparticule enzyme immunoassay and confirmed by immunoblotting method, were included in the study. The nucleic acids obtained simultaneously by manual isolation kit (Cobas Amplicor, HIV-1 Monitor Test, version 1.5, Roche Diagnostics) and automated system (MagNA Pure LC Total Nucleic Acid Isolation Kit, Roche Diagnostics), were amplified and detected in Cobas Amplicor (Roche Diagnostics) instrument. Twenty three of 35 samples (65.7%) were found to be positive, and 9 (25.7%) were negative by both of the methods. The agreement between the methods were detected as 91.4%, for qualitative results. Viral RNA copies detected by manual and MagNA Pure isolation methods were found between 76.0-7.590.000 (mean: 487.143) and 113.0-20.300.0000 (mean: 2.174.097) copies/ml, respectively. When both of the overall and individual results were evaluated, the number of RNA copies obtained with automatized system, were found higher than the manual method (p<0.05). Three samples which had low numbers of nucleic acids (113, 773, 857, respectively) with MagNA Pure, yielded negative results with manual method. In conclusion, the automatized MagNA Pure system was found to be a reliable, rapid and practical method for the isolation of HIV-RNA.

  7. The Hubble Space Telescope Wide Field Camera 3 Early Release Science Data: Panchromatic Faint Object Counts From 0.2-2 Micron To Ab=26-27 Mag

    NASA Astrophysics Data System (ADS)

    Windhorst, Rogier A.; McCarthy, P.; Cohen, S.; Ryan, R.; Driver, S.; Hathi, N.; Koekemoer, A.; Mechtley, M.; O'Connell, R.; Rutkowski, M.; Yan, H.; SOC, WFC3

    2010-01-01

    We describe the Hubble Space Telescope (HST) Wide Field Camera 3 (WFC3) Early Release Science (ERS) observations in the GOODS-South field. The new WFC3 ERS data provide calibrated, drizzled mosaics with FHWM=0.07--0.15" in the near-UV (filters F225W, F275W, and F336W) and near-IR (F098W, F125W, and F160W) in typically 2 orbits per filter. Together with the existing HST/ACS GOODS-S mosaics in the BVi'z' filters, the 10-band ERS data cover 40-50 sq. arcmin to AB=26-27.0 mag (10-sigma for point sources). In this poster, we describe the: (1) scientific rationale, data taking and reduction procedures of the WFC3 ERS mosaics; (2) object cataloging and star-galaxy separation techniques used in these 10 different filters; (3) reliability and completeness of the 10-band object catalogs from the ERS mosaics; (4) object counts in 10 different filters from 0.2-1.7 microns to AB=26.0-27.0 mag; and (5) the full-color 10-band ERS images. We discuss the panchromatic structure for a variety of interesting ERS objects at intermediate redshifts (z=0.5-3), including examples of galaxies with nuclear star-forming rings, bars, or weak AGN activity, UV-dropout galaxies at redshifts z=2-3, and objects of other interesting appearance. The 10-band panchromatic ERS data base is very rich in morphological structure at all restframe wavelengths where young or older stars shine during the peak epoch in the cosmic star-formation rate (at z=1-2). This work is based on ERS observations made by the WFC3 Scientific Oversight Committee. We are grateful to the Space Telescope Science Institute Director for awarding Director's Discretionary time for this program. Support for HST program 11359 was provided by NASA through grants GO-11359.0*.A from STScI, which is operated by AURA under NASA contract NAS 5-26555. We dedicate this paper to the memory of the STS-107 Columbia Shuttle astronauts, and of Dr. Rodger Doxsey.

  8. Comparison of the Incorporation of DHA in Circulatory and Neural Tissue When Provided as Triacylglycerol (TAG), Monoacylglycerol (MAG) or Phospholipids (PL) Provides New Insight into Fatty Acid Bioavailability.

    PubMed

    Destaillats, Frédéric; Oliveira, Manuel; Bastic Schmid, Viktoria; Masserey-Elmelegy, Isabelle; Giuffrida, Francesca; Thakkar, Sagar K; Dupuis, Lénaïck; Gosoniu, Maria Laura; Cruz-Hernandez, Cristina

    2018-05-15

    Phospholipids (PL) or partial acylglycerols such as sn -1(3)-monoacylglycerol (MAG) are potent dietary carriers of long-chain polyunsaturated fatty acids (LC-PUFA) and have been reported to provide superior bioavailability when compared to conventional triacylglycerol (TAG). The main objective of the present study was to compare the incorporation of docosahexaenoic acid (DHA) in plasma, erythrocytes, retina and brain tissues in adult rats when provided as PL (PL-DHA) and MAG (MAG-DHA). Conventional dietary DHA oil containing TAG (TAG-DHA) as well as control chow diet were used to evaluate the potency of the two alternative DHA carriers over a 60-day feeding period. Fatty acid profiles were determined in erythrocytes and plasma lipids at time 0, 7, 14, 28, 35 and 49 days of the experimental period and in retina, cortex, hypothalamus, and hippocampus at 60 days. The assessment of the longitudinal evolution of DHA in erythrocyte and plasma lipids suggest that PL-DHA and MAG-DHA are efficient carriers of dietary DHA when compared to conventional DHA oil (TAG-DHA). Under these experimental conditions, both PL-DHA and MAG-DHA led to higher incorporations of DHA erythrocytes lipids compared to TAG-DHA group. After 60 days of supplementation, statistically significant increase in DHA level incorporated in neural tissues analyzed were observed in the DHA groups compared with the control. The mechanism explaining hypothetically the difference observed in circulatory lipids is discussed.

  9. Comparison of the Incorporation of DHA in Circulatory and Neural Tissue When Provided as Triacylglycerol (TAG), Monoacylglycerol (MAG) or Phospholipids (PL) Provides New Insight into Fatty Acid Bioavailability

    PubMed Central

    Destaillats, Frédéric; Oliveira, Manuel; Bastic Schmid, Viktoria; Masserey-Elmelegy, Isabelle; Giuffrida, Francesca; Thakkar, Sagar K.; Dupuis, Lénaïck; Gosoniu, Maria Laura; Cruz-Hernandez, Cristina

    2018-01-01

    Phospholipids (PL) or partial acylglycerols such as sn-1(3)-monoacylglycerol (MAG) are potent dietary carriers of long-chain polyunsaturated fatty acids (LC-PUFA) and have been reported to provide superior bioavailability when compared to conventional triacylglycerol (TAG). The main objective of the present study was to compare the incorporation of docosahexaenoic acid (DHA) in plasma, erythrocytes, retina and brain tissues in adult rats when provided as PL (PL-DHA) and MAG (MAG-DHA). Conventional dietary DHA oil containing TAG (TAG-DHA) as well as control chow diet were used to evaluate the potency of the two alternative DHA carriers over a 60-day feeding period. Fatty acid profiles were determined in erythrocytes and plasma lipids at time 0, 7, 14, 28, 35 and 49 days of the experimental period and in retina, cortex, hypothalamus, and hippocampus at 60 days. The assessment of the longitudinal evolution of DHA in erythrocyte and plasma lipids suggest that PL-DHA and MAG-DHA are efficient carriers of dietary DHA when compared to conventional DHA oil (TAG-DHA). Under these experimental conditions, both PL-DHA and MAG-DHA led to higher incorporations of DHA erythrocytes lipids compared to TAG-DHA group. After 60 days of supplementation, statistically significant increase in DHA level incorporated in neural tissues analyzed were observed in the DHA groups compared with the control. The mechanism explaining hypothetically the difference observed in circulatory lipids is discussed. PMID:29762503

  10. The use of {sup 99m}Tc-Al{sub 2}O{sub 3} for detection of sentinel lymph nodes in breast cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sinilkin, I., E-mail: sinilkinig@oncology.tomsk.ru; Chernov, V.; Medvedeva, A.

    2016-08-02

    Purpose: to study the feasibility of using the new radiopharmaceutical based on the technetium-99m-labeled gamma-alumina for identification of sentinel lymph nodes (SLNs) in breast cancer patients. The study included two groups of breast cancer patients who underwent single photon emission computed tomography (SPECT) and intraoperaive gamma probe identification of sentinel lymph nodes (SLNs). To identify SLNs, the day before surgery Group I patients (n = 34) were injected with radioactive {sup 99m}Tc-Al{sub 2}O{sub 3}, and Group II patients (n = 30) received {sup 99m}Tc-labeled phytate colloid. A total of 37 SLNs were detected in Group I patients. The number ofmore » identified SLNs per patient ranged from 1 to 2 (the average number of identified SLNs was 1.08). Axillary lymph nodes were the most common site of SLN localization. 18 hours after {sup 99m}Tc-Al{sub 2}O{sub 3} injection, the percentage of its accumulation in the SLN was 7–11% (of the counts in the injection site) by SPECT and 17–31% by gamma probe detection. In Group II SLNs were detected in 27 patients. 18 hours after injection of the phytate colloid the percentage of its accumulation in the SLN was 1.5–2% out of the counts in the injection site by SPECT and 4–7% by gamma probe. The new radiopharmaceutical based on the {sup 99m}Tc-Al{sub 2}O{sub 3} demonstrates high accumulation in SLNs without redistribution through the entire lymphatic basin. The sensitivity and specificity of {sup 99m}Tc-Al{sub 2}O{sub 3} were 100% for both SPECT and intraoperative gamma probe identification.« less

  11. Development of a Magnetic Microbead Affinity Selection Screen (MagMASS) Using Mass Spectrometry for Ligands to the Retinoid X Receptor-α

    NASA Astrophysics Data System (ADS)

    Rush, Michael D.; Walker, Elisabeth M.; Prehna, Gerd; Burton, Tristesse; van Breemen, Richard B.

    2017-03-01

    To overcome limiting factors in mass spectrometry-based screening methods such as automation while still facilitating the screening of complex mixtures such as botanical extracts, magnetic microbead affinity selection screening (MagMASS) was developed. The screening process involves immobilization of a target protein on a magnetic microbead using a variety of possible chemistries, incubation with mixtures of molecules containing possible ligands, a washing step that removes non-bound compounds while a magnetic field retains the beads in the microtiter well, and an organic solvent release step followed by LC-MS analysis. Using retinoid X receptor-α (RXRα) as an example, which is a nuclear receptor and target for anti-inflammation therapy as well as cancer treatment and prevention, a MagMASS assay was developed and compared with an existing screening assay, pulsed ultrafiltration (PUF)-MS. Optimization of MagMASS involved evaluation of multiple protein constructs and several magnetic bead immobilization chemistries. The full-length RXRα construct immobilized with amylose beads provided optimum results. Additional enhancements of MagMASS were the application of 96-well plates to enable automation, use of UHPLC instead of HPLC for faster MS analyses, and application of metabolomics software for faster, automated data analysis. Performance of MagMASS was demonstrated using mixtures of synthetic compounds and known ligands spiked into botanical extracts.

  12. The role of dynamic renal scintigraphy on clinical decision making in hydronephrotic children.

    PubMed

    Çamlar, Seçil Arslansoyu; Deveci, Nazlı; Soylu, Alper; Türkmen, Mehmet Atilla; Özmen, Derya; Çapakaya, Gamze; Kavukçu, Salih

    2017-01-01

    Hydronephrosis may be related to an obstructive cause, ureteropelvic/uretero-vesical junction obstruction or nonobstructive [vesicoureteral reflux (VUR)]. When an obstructive pathology is considered, dynamic renal scintigraphy may help to predict whether it is a true obstruction or not. In this study, we aimed to determine the contribution of dynamic renal scintigraphy with [99] mTc-MAG-3 to the clinical decision-making for surgery in hydronephrotic children. Files of the patients evaluated by MAG-3 scintigraphy for antenatal (AH)/postnatal (PH) hydronephrosis between 1992 and 2014 were reviewed. Gender, age, hydronephrosis (HN) grade by ultrasound (US), presence of VUR, MAG-3 result (obstructive vs. nonobstructive), ultimate diagnosis, and need for surgery were assessed. Cases with double collecting system and neurogenic bladder were excluded from the study. All of the patients had normal serum creatinine and eGFR. There were a total of 178 patients with 218 hydronephrotic renal units (mean age 34.7 ± 52.7 months; male/ female = 121/57, AH of 62%). MAG-3 was nonobstructive in 134 and obstructive in 84 hydronephrotic renal units. MAG-3 was obstructive in 47 of 121 (39%) males and 30 of 57 (53%) females (P = 0.058, odds ratio (OR) for obstruction was 1.9 for girls). MAG-3 was obstructive in 47 of 135 (35%) units with AH and 37 of 83 (45%) units with PH (P = 0.137). In 81 units with the society of fetal urology-4 HN by US, MAG-3 was obstructive in 55 (68%), and surgery was required in 52 of 55 (95%). Surgery was required for only two (7%) of the remaining 26 units with nonobstructive dilatation (P <0.001, sensitivity 96%, specificity 89%, OR 208). Antero-posterior diameter >16.5 mm was the best cutoff level for predicting obstruction by MAG-3 (sensitivity 75.2%; specificity 71%; OR 3.8). MAG-3 significantly affects clinical decision for surgery in HN. Hydronephrotic girls have more risk in terms of true obstruction. Combining MAG-3 with US improves the

  13. Making the MagIC (Magnetics Information Consortium) Web Application Accessible to New Users and Useful to Experts

    NASA Astrophysics Data System (ADS)

    Minnett, R.; Koppers, A.; Jarboe, N.; Tauxe, L.; Constable, C.; Jonestrask, L.

    2017-12-01

    Challenges are faced by both new and experienced users interested in contributing their data to community repositories, in data discovery, or engaged in potentially transformative science. The Magnetics Information Consortium (https://earthref.org/MagIC) has recently simplified its data model and developed a new containerized web application to reduce the friction in contributing, exploring, and combining valuable and complex datasets for the paleo-, geo-, and rock magnetic scientific community. The new data model more closely reflects the hierarchical workflow in paleomagnetic experiments to enable adequate annotation of scientific results and ensure reproducibility. The new open-source (https://github.com/earthref/MagIC) application includes an upload tool that is integrated with the data model to provide early data validation feedback and ease the friction of contributing and updating datasets. The search interface provides a powerful full text search of contributions indexed by ElasticSearch and a wide array of filters, including specific geographic and geological timescale filtering, to support both novice users exploring the database and experts interested in compiling new datasets with specific criteria across thousands of studies and millions of measurements. The datasets are not large, but they are complex, with many results from evolving experimental and analytical approaches. These data are also extremely valuable due to the cost in collecting or creating physical samples and the, often, destructive nature of the experiments. MagIC is heavily invested in encouraging young scientists as well as established labs to cultivate workflows that facilitate contributing their data in a consistent format. This eLightning presentation includes a live demonstration of the MagIC web application, developed as a configurable container hosting an isomorphic Meteor JavaScript application, MongoDB database, and ElasticSearch search engine. Visitors can explore the Mag

  14. The Foreign Clast Populations of Anomalous Polymict Urelite Almahata Sitta (Asteroid 2008 TC(sub3) and Typical Polymict Ureilites: Implications for Asteroid-Meteorite Connections

    NASA Technical Reports Server (NTRS)

    Goodrich, C. A.; Treiman, A. H.; Zolensky, M.; Kita, N. T.; Defouilloy, C.; Fioretti, A. M.; O'Brien, D. P.; Jenniskens, P.; Shaddad, M. H.

    2016-01-01

    Almahata Sitta (AhS) is the first meteorite to originate from an asteroid (2008 TC3) that had been studied in space before it hit Earth [1,2]. It is also unique because the fallen fragments comprise a variety of types: approximately 69% ureilites (achondrites) and 31% chondrites [3]. Two models have been proposed for the origin 2008 TC3: 1) an accretionary model [3,4]; or 2) a regolith model [5,6]. Typical polymict ureilites are interpreted to represent regolith, and contain a few % foreign clasts [7,8]. The most common are dark (CC matrix-like) clasts similar to those in many meteoritic breccias [9]. A variety of other chondrites, as well as achondrites (angrites), have also been reported [7,9,10]. We have been working to determine the full diversity of these clasts [10-13] for comparison with AhS. We discuss implications for mixing of materials in the early solar system and the origin of 2008 TC3.

  15. Microscopic model for the isotope effect in the high-Tc oxides

    NASA Astrophysics Data System (ADS)

    Kresin, V. Z.; Wolf, S. A.

    1994-02-01

    An unconventional microscopic mechanism relating Tc and the isotope substitution for the doped superconductors such as the high-Tc oxides is proposed. Strong nonadiabaticity, when it is impossible, strictly speaking, to separate fully the nuclear and electronic degrees of freedom, leads to a peculiar dependence of the carrier concentration n on the ionic mass M. This case corresponds, for example, to the isotopic substitution of the axial oxygen in YBa2Cu3O7-x. Because of the dependence of Tc on n, this leads to the dependence of Tc on M, that is to the isotope effect. The minimum value of the isotope coefficient corresponds to Tc=Tmaxc.

  16. Blood lipid-lowering and antioxidant effects of a structured lipid containing monoacylglyceride enriched with monounsaturated fatty acids in C57BL/6 mice.

    PubMed

    Cho, Kyung-Hyun; Lee, Jeung-Hee; Kim, Jin-Man; Park, Sang Hyun; Choi, Myung-Sook; Lee, Yun-Mi; Choi, Inho; Lee, Ki-Teak

    2009-04-01

    We recently reported that a synthetic edible oil-containing monoacylglyceride (MAG) and diacylglyceride (DAG) exerted anti-atherosclerotic effects. In order to further investigate the activities and individual effects of MAG and DAG on the atherosclerotic process, we prepared a structured oil with various MAG and DAG contents and tested them both in vitro and in vivo, using C57BL/6 mice. The structured oil to be tested was mixed (final concentration 5%, wt/wt) with a high-cholesterol high-fat diet (1.2% cholesterol/15% fat/0.5% sodium cholate) and provided to the mice for 7 weeks. After administration, the mice consuming MAG97%-oil and DAG50%/MAG10%-oil evidenced 17% and 24% decreases in plasma total cholesterol (TC) level, respectively, as compared to a group of mice fed on lard. The experimental mice also had reduced plasma triglyceride concentrations and elevated high-density lipoprotein-cholesterol to TC ratios, by up to 31% in the case of the DAG50%/MAG10%-oil fed mice. The mice fed on MAG97%-oil exhibited elevated plasma antioxidant activity and lecithin:cholesterol acyltransferase activity. Histological assessments of the livers of the mice showed that the consumption of MAG-containing oil attenuated the adhesion of inflammatory cells and also ameliorated fatty liver changes, as compared to what was observed in the case of DAG85%-oil consumption. In conclusion, the MAG-containing oil exhibited anti-inflammatory and antioxidant activities in vivo, as well as in vitro inhibitory activity against human cholesteryl ester transfer protein. These results provide us with new insights into MAG-containing oil in terms of hypocholesterolemic effects and antioxidant activities.

  17. Reduction and Simultaneous Removal of 99 Tc and Cr by Fe(OH) 2 (s) Mineral Transformation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saslow, Sarah A.; Um, Wooyong; Pearce, Carolyn I.

    Technetium (Tc) remains a priority remediation concern due to persistent challenges, including rapid re-oxidation of immobilized Tc, and competing contaminants, e.g. Cr(VI), that inhibit targeted Tc reduction and incorporation into stable mineral phases. Here Fe(OH) 2(s) is investigated as a comprehensive solution for overcoming these challenges, by serving as both the reductant, (Fe(II)), and immobilization agent to form Tc-incorporated magnetite (Fe 3O 4). Trace metal analysis suggests removal of Tc(VII) and Cr(VI) from solution occurs simultaneously; however, complete removal and reduction of Cr(VI) is achieved earlier than the removal/reduction of co-mingled Tc(VII). Bulk oxidation state analysis of the magnetite solidmore » phase by XANES confirms that the majority of Tc is Tc(IV), which is corroborated by XPS. Furthermore, EXAFS results show successful Tc(IV) incorporation into magnetite octahedral sites without additional substitution of Cr or Tc into neighboring Fe octahedral sites. XPS analysis of Cr confirms reduction to Cr(III) and the formation of a Cr-incorporated spinel, Cr2O 3, and Cr(OH)3 phases. Spinel (modeled as Fe 3O 4), goethite, and feroxyhyte are detected in all reacted solid phase samples analyzed by XRD, where Tc(IV) incorporation has little effect on the spinel lattice structure. In the presence of Cr(III) a spinel phase along the magnetite-chromite (Fe 3O 4-FeCr 2O 4) solid-solution line is formed.« less

  18. Comparison of LDPI to SPECT perfusion imaging using (99m)Tc-sestamibi and (99m)Tc-pyrophosphate in a murine ischemic hind limb model of neovascularization.

    PubMed

    Hendrikx, Geert; Vries, Mark H; Bauwens, Matthias; De Saint-Hubert, Marijke; Wagenaar, Allard; Guillaume, Joël; Boonen, Levinia; Post, Mark J; Mottaghy, Felix M

    2016-12-01

    We aimed to determine the accuracy of laser Doppler perfusion imaging (LDPI) in an animal model for hind limb ischemia. We used a murine (C57Bl/6 mice) ischemic hind limb model in which we compared LDPI with the clinically used (99m)Tc-sestamibi SPECT perfusion imaging (n = 7). In addition, we used the SPECT tracer (99m)Tc-pyrophosphate ((99m)Tc-PyP) to image muscular damage (n = 6). LDPI indicated a quick and prominent decrease in perfusion immediately after ligation, subsequently recovering to 21.9 and 25.2 % 14 days later in the (99m)Tc-sestamibi and (99m)Tc-PyP group, respectively. (99m)Tc-sestamibi SPECT scans also showed a quick decrease in perfusion. However, nearly full recovery was reached 7 days post ligation. Muscular damage, indicated by the uptake of (99m)Tc-PyP, was highest at day 3 and recovered to baseline levels at day 14 post ligation. Postmortem histology supported these findings, as a significantly increased collateral diameter was found 7 and 14 days after ligation and peak macrophage infiltration and TUNEL positivity was found on day 3 after ligation. Here, we indicate that LDPI strongly underestimates perfusion recovery in a hind limb model for profound ischemia.

  19. In vitro and in vivo comparison of binding of 99m-Tc-labeled anti-CEA MAb F33-104 with 99m-Tc-labeled anti-CEA MAb BW431/26.

    PubMed

    Watanabe, N; Oriuchi, N; Sugiyama, S; Kuroki, M; Matsuoka, Y; Tanada, S; Murata, H; Inoue, T; Sasaki, Y

    1999-01-01

    The purpose of this study was to assess the potential for radio-immunodetection (RAID) of murine anti-carcinoembryonic antigen (CEA) monoclonal antibody (MAb) F33-104 labeled with technetium-99m (99m-Tc) by a reduction-mediated labeling method. The binding capacity of 99m-Tc-labeled anti-CEA MAb F33-104 with CEA by means of in vitro procedures such as immunoradiometric assay and cell binding assay and the biodistribution of 99m-Tc-labeled anti-CEA MAb F33-104 in normal nude mice and nude mice bearing human colon adenocarcinoma LS180 tumor were investigated and compared with 99m-Tc-labeled anti-CEA MAb BW431/26. The in vitro binding rate of 99m-Tc-labeled anti-CEA MAb F33-104 with CEA in solution and attached to the cell membrane was significantly higher than 99m-Tc-labeled anti-CEA MAb BW431/261 (31.4 +/- 0.95% vs. 11.9 +/- 0.55% at 100 ng/mL of soluble CEA, 83.5 +/- 2.84% vs. 54.0 +/- 2.54% at 10(7) of LS 180 cells). In vivo, accumulation of 99m-Tc-labeled anti-CEA MAb F33-104 was higher at 18 h postinjection than 99m-Tc-labeled anti-CEA MAb BW431/26 (20.1 +/- 3.50% ID/g vs. 14.4 +/- 3.30% ID/g). 99m-Tc-activity in the kidneys of nude mice bearing tumor was higher at 18 h postinjection than at 3 h (12.8 +/- 2.10% ID/g vs. 8.01 +/- 2.40% ID/g of 99m-Tc-labeled anti-CEA MAb F33-104, 10.7 +/- 1.70% ID/g vs. 8.10 +/- 1.75% ID/g of 99m-Tc-labeled anti-CEA MAb BW431/26). 99m-Tc-labeled anti-CEA MAb F33-104 is a potential novel agent for RAID of recurrent colorectal cancer.

  20. Diversification of 99Mo/99mTc separation: non–fission reactor production of 99Mo as a strategy for enhancing 99mTc availability.

    PubMed

    Pillai, Maroor R A; Dash, Ashutosh; Knapp, Furn F Russ

    2015-01-01

    This paper discusses the benefits of obtaining (99m)Tc from non-fission reactor-produced low-specific-activity (99)Mo. This scenario is based on establishing a diversified chain of facilities for the distribution of (99m)Tc separated from reactor-produced (99)Mo by (n,γ) activation of natural or enriched Mo. Such facilities have expected lower investments than required for the proposed chain of cyclotrons for the production of (99m)Tc. Facilities can receive and process reactor-irradiated Mo targets then used for extraction of (99m)Tc over a period of 2 wk, with 3 extractions on the same day. Estimates suggest that a center receiving 1.85 TBq (50 Ci) of (99)Mo once every 4 d can provide 1.48-3.33 TBq (40-90 Ci) of (99m)Tc daily. This model can use research reactors operating in the United States to supply current (99)Mo needs by applying natural (nat)Mo targets. (99)Mo production capacity can be enhanced by using (98)Mo-enriched targets. The proposed model reduces the loss of (99)Mo by decay and avoids proliferation as well as waste management issues associated with fission-produced (99)Mo.

  1. Tc-99m Ethylenedicysteine and Tc-99m Dimercaptosuccinic Acid Scintigraphy-Comparison of the Two for Detection of Scarring and Differential Cortical Function.

    PubMed

    Dharmalingam, Anitha; Pawar, Shwetal U; Parelkar, Sandesh V; Shetye, Suruchi S; Ghorpade, Mangala K; Tilve, Gundu H

    2017-01-01

    The differential cortical function obtained by Tc-99m EC is comparable to that of Tc-99m DMSA. However, identification of scars on Tc-99m EC images needs to be studied. The aim of the study is to evaluate role of Tc-99m EC for detection of scarring and differential cortical function by comparing with Tc-99m DMSA. Prospective observational study of recurrent UTI; minimum 6 weeks after acute episode; when urine examination is negative for pus cells. Forty-seven children with normal positioned kidneys underwent Tc-99m EC and DMSA scintigraphy. The DRF and cortical phase images of both studies in the same image matrix size were evaluated by two independent observers for scarring; Tc-99m DMSA was considered as the gold standard. MS Excel 2007 and GraphPad Instat V3.1 and ROC analysis. There was no significant difference in the detection of scarring using two studies with Cohen's kappa coefficient (κ) 0.932. The sensitivity and specificity of Tc-99m EC for detection of scarring was 98.75% and 99.15%, respectively. There was good agreement between the differential cortical function calculated using two studies. The summed Tc-99m EC images with an acceptable high image contrast allow detection of cortical scarring in patients with normal kidney positions. It is an excellent single-modality comprehensive investigational agent for renal parenchymal defects, function, and excretion evaluation with the added advantages of lower cost, convenience, and low radiation exposure to the child.

  2. Interplanetary Dust Observations by the Juno MAG Investigation

    NASA Astrophysics Data System (ADS)

    Jørgensen, John; Benn, Mathias; Denver, Troelz; Connerney, Jack; Jørgensen, Peter; Bolton, Scott; Brauer, Peter; Levin, Steven; Oliversen, Ronald

    2017-04-01

    The spin-stabilized and solar powered Juno spacecraft recently concluded a 5-year voyage through the solar system en route to Jupiter, arriving on July 4th, 2016. During the cruise phase from Earth to the Jovian system, the Magnetometer investigation (MAG) operated two magnetic field sensors and four co-located imaging systems designed to provide accurate attitude knowledge for the MAG sensors. One of these four imaging sensors - camera "D" of the Advanced Stellar Compass (ASC) - was operated in a mode designed to detect all luminous objects in its field of view, recording and characterizing those not found in the on-board star catalog. The capability to detect and track such objects ("non-stellar objects", or NSOs) provides a unique opportunity to sense and characterize interplanetary dust particles. The camera's detection threshold was set to MV9 to minimize false detections and discourage tracking of known objects. On-board filtering algorithms selected only those objects tracked through more than 5 consecutive images and moving with an apparent angular rate between 15"/s and 10,000"/s. The coordinates (RA, DEC), intensity, and apparent velocity of such objects were stored for eventual downlink. Direct detection of proximate dust particles is precluded by their large (10-30 km/s) relative velocity and extreme angular rates, but their presence may be inferred using the collecting area of Juno's large ( 55m2) solar arrays. Dust particles impact the spacecraft at high velocity, creating an expanding plasma cloud and ejecta with modest (few m/s) velocities. These excavated particles are revealed in reflected sunlight and tracked moving away from the spacecraft from the point of impact. Application of this novel detection method during Juno's traversal of the solar system provides new information on the distribution of interplanetary (µm-sized) dust.

  3. Cost-Savings Analysis of Renal Scintigraphy, Stratified by Renal Function Thresholds: Mercaptoacetyltriglycine Versus Diethylene Triamine Penta-Acetic Acid.

    PubMed

    Parikh, Kushal R; Davenport, Matthew S; Viglianti, Benjamin L; Hubers, David; Brown, Richard K J

    2016-07-01

    To determine the financial implications of switching technetium (Tc)-99m mercaptoacetyltriglycine (MAG-3) to Tc-99m diethylene triamine penta-acetic acid (DTPA) at certain renal function thresholds before renal scintigraphy. Institutional review board approval was obtained, and informed consent was waived for this HIPAA-compliant, retrospective, cohort study. Consecutive adult subjects (27 inpatients; 124 outpatients) who underwent MAG-3 renal scintigraphy, in the period from July 1, 2012 to June 30, 2013, were stratified retrospectively by hypothetical serum creatinine and estimated glomerular filtration rate (eGFR) thresholds, based on pre-procedure renal function. Thresholds were used to estimate the financial effects of using MAG-3 when renal function was at or worse than a given cutoff value, and DTPA otherwise. Cost analysis was performed with consideration of raw material and preparation costs, with radiotracer costs estimated by both vendor list pricing and proprietary institutional pricing. The primary outcome was a comparison of each hypothetical threshold to the clinical reality in which all subjects received MAG-3, and the results were supported by univariate sensitivity analysis. Annual cost savings by serum creatinine threshold were as follows (threshold given in mg/dL): $17,319 if ≥1.0; $33,015 if ≥1.5; and $35,180 if ≥2.0. Annual cost savings by eGFR threshold were as follows (threshold given in mL/min/1.73 m(2)): $21,649 if ≤60; $28,414 if ≤45; and $32,744 if ≤30. Cost-savings inflection points were approximately 1.25 mg/dL (serum creatinine) and 60 mL/min/1.73m(2) (eGFR). Secondary analysis by proprietary institutional pricing revealed similar trends, and cost savings of similar magnitude. Sensitivity analysis confirmed cost savings at all tested thresholds. Reserving MAG-3 utilization for patients who have impaired renal function can impart substantial annual cost savings to a radiology department. Copyright © 2016 American College

  4. First closed-loop visible AO test results for the advanced adaptive secondary AO system for the Magellan Telescope: MagAO's performance and status

    NASA Astrophysics Data System (ADS)

    Close, Laird M.; Males, Jared R.; Kopon, Derek A.; Gasho, Victor; Follette, Katherine B.; Hinz, Phil; Morzinski, Katie; Uomoto, Alan; Hare, Tyson; Riccardi, Armando; Esposito, Simone; Puglisi, Alfio; Pinna, Enrico; Busoni, Lorenzo; Arcidiacono, Carmelo; Xompero, Marco; Briguglio, Runa; Quiros-Pacheco, Fernando; Argomedo, Javier

    2012-07-01

    The heart of the 6.5 Magellan AO system (MagAO) is a 585 actuator adaptive secondary mirror (ASM) with <1 msec response times (0.7 ms typically). This adaptive secondary will allow low emissivity and high-contrast AO science. We fabricated a high order (561 mode) pyramid wavefront sensor (similar to that now successfully used at the Large Binocular Telescope). The relatively high actuator count (and small projected ~23 cm pitch) allows moderate Strehls to be obtained by MagAO in the “visible” (0.63-1.05 μm). To take advantage of this we have fabricated an AO CCD science camera called "VisAO". Complete “end-to-end” closed-loop lab tests of MagAO achieve a solid, broad-band, 37% Strehl (122 nm rms) at 0.76 μm (i’) with the VisAO camera in 0.8” simulated seeing (13 cm ro at V) with fast 33 mph winds and a 40 m Lo locked on R=8 mag artificial star. These relatively high visible wavelength Strehls are enabled by our powerful combination of a next generation ASM and a Pyramid WFS with 400 controlled modes and 1000 Hz sample speeds (similar to that used successfully on-sky at the LBT). Currently only the VisAO science camera is used for lab testing of MagAO, but this high level of measured performance (122 nm rms) promises even higher Strehls with our IR science cameras. On bright (R=8 mag) stars we should achieve very high Strehls (>70% at H) in the IR with the existing MagAO Clio2 (λ=1-5.3 μm) science camera/coronagraph or even higher (~98% Strehl) the Mid-IR (8-26 microns) with the existing BLINC/MIRAC4 science camera in the future. To eliminate non-common path vibrations, dispersions, and optical errors the VisAO science camera is fed by a common path advanced triplet ADC and is piggy-backed on the Pyramid WFS optical board itself. Also a high-speed shutter can be used to block periods of poor correction. The entire system passed CDR in June 2009, and we finished the closed-loop system level testing phase in December 2011. Final system acceptance (

  5. CrowdMag - Crowdsourcing magnetic data

    NASA Astrophysics Data System (ADS)

    Nair, M. C.; Boneh, N.; Chulliat, A.

    2014-12-01

    In the CrowdMag project, we explore whether digital magnetometers built in modern mobile phones can be used as scientific instruments to measure Earth's magnetic field. Most modern mobile phones have digital magnetometers to orient themselves. A phone's magnetometer measures three components of the local magnetic field with a typical sensitivity of about 150 to 600 nanotesla (nT). By combining data from vector magnetometers and accelerometers, phone's orientation is determined. Using phone's Internet connection, magnetic data and location are sent to a central server. At the server, we check quality of the magnetic data from all users and make the data available to the public as aggregate maps. We have two long-term goals. 1) Develop near-real-time models of Earth's time changing magnetic field by reducing man-made noise from crowdsourced data and combining it with geomagnetic data from other sources. 2) Improving accuracy of magnetic navigation by mapping magnetic noise sources (for e.g. power transformer and iron pipes). Key challenges to this endeavor are the low sensitivity of the phone's magnetometer and the noisy environment within and surrounding the phone. URL : http://www.ngdc.noaa.gov/geomag/crowdmag.shtml

  6. Behavioral Abnormalities in a Mouse Model of Chronic Toxoplasmosis Are Associated with MAG1 Antibody Levels and Cyst Burden.

    PubMed

    Xiao, Jianchun; Li, Ye; Prandovszky, Emese; Kannan, Geetha; Viscidi, Raphael P; Pletnikov, Mikhail V; Yolken, Robert H

    2016-04-01

    There is marked variation in the human response to Toxoplasma gondii infection. Epidemiological studies indicate associations between strain virulence and severity of toxoplasmosis. Animal studies on the pathogenic effect of chronic infection focused on relatively avirulent strains (e.g. type II) because they can easily establish latent infections in mice, defined by the presence of bradyzoite-containing cysts. To provide insight into virulent strain-related severity of human toxoplasmosis, we established a chronic model of the virulent type I strain using outbred mice. We found that type I-exposed mice displayed variable outcomes ranging from aborted to severe infections. According to antibody profiles, we found that most of mice generated antibodies against T. gondii organism but varied greatly in the production of antibodies against matrix antigen MAG1. There was a strong correlation between MAG1 antibody level and brain cyst burden in chronically infected mice (r = 0.82, p = 0.0021). We found that mice with high MAG1 antibody level displayed lower weight, behavioral changes, altered levels of gene expression and immune activation. The most striking change in behavior we discovered was a blunted response to amphetamine-trigged locomotor activity. The extent of most changes was directly correlated with levels of MAG1 antibody. These changes were not found in mice with less cyst burden or mice that were acutely but not chronically infected. Our finding highlights the critical role of cyst burden in a range of disease severity during chronic infection, the predictive value of MAG1 antibody level to brain cyst burden and to changes in behavior or other pathology in chronically infected mice. Our finding may have important implications for understanding the heterogeneous effects of T. gondii infections in human.

  7. Behavioral Abnormalities in a Mouse Model of Chronic Toxoplasmosis Are Associated with MAG1 Antibody Levels and Cyst Burden

    PubMed Central

    Xiao, Jianchun; Li, Ye; Prandovszky, Emese; Kannan, Geetha; Viscidi, Raphael P.; Pletnikov, Mikhail V.; Yolken, Robert H.

    2016-01-01

    There is marked variation in the human response to Toxoplasma gondii infection. Epidemiological studies indicate associations between strain virulence and severity of toxoplasmosis. Animal studies on the pathogenic effect of chronic infection focused on relatively avirulent strains (e.g. type II) because they can easily establish latent infections in mice, defined by the presence of bradyzoite-containing cysts. To provide insight into virulent strain-related severity of human toxoplasmosis, we established a chronic model of the virulent type I strain using outbred mice. We found that type I-exposed mice displayed variable outcomes ranging from aborted to severe infections. According to antibody profiles, we found that most of mice generated antibodies against T. gondii organism but varied greatly in the production of antibodies against matrix antigen MAG1. There was a strong correlation between MAG1 antibody level and brain cyst burden in chronically infected mice (r = 0.82, p = 0.0021). We found that mice with high MAG1 antibody level displayed lower weight, behavioral changes, altered levels of gene expression and immune activation. The most striking change in behavior we discovered was a blunted response to amphetamine-trigged locomotor activity. The extent of most changes was directly correlated with levels of MAG1 antibody. These changes were not found in mice with less cyst burden or mice that were acutely but not chronically infected. Our finding highlights the critical role of cyst burden in a range of disease severity during chronic infection, the predictive value of MAG1 antibody level to brain cyst burden and to changes in behavior or other pathology in chronically infected mice. Our finding may have important implications for understanding the heterogeneous effects of T. gondii infections in human. PMID:27124472

  8. Clickable, Hydrophilic Ligand for fac-[MI(CO)3]+ (M = Re/99mTc) Applied in an S-Functionalized α-MSH Peptide

    PubMed Central

    2015-01-01

    The copper(I)-catalyzed azide–alkyne cycloaddition (CuAAC) click reaction was used to incorporate alkyne-functionalized dipicolylamine (DPA) ligands (1 and 3) for fac-[MI(CO)3]+ (M = Re/99mTc) complexation into an α-melanocyte stimulating hormone (α-MSH) peptide analogue. A novel DPA ligand with carboxylate substitutions on the pyridyl rings (3) was designed to increase the hydrophilicity and to decrease in vivo hepatobiliary retention of fac-[99mTcI(CO)3]+ complexes used in single photon emission computed tomography (SPECT) imaging studies with targeting biomolecules. The fac-[ReI(CO)3(3)] complex (4) was used for chemical characterization and X-ray crystal analysis prior to radiolabeling studies between 3 and fac-[99mTcI(OH2)3(CO)3]+. The corresponding 99mTc complex (4a) was obtained in high radiochemical yields, was stable in vitro for 24 h during amino acid challenge and serum stability assays, and showed increased hydrophilicity by log P analysis compared to an analogous complex with nonfunctionalized pyridine rings (2a). An α-MSH peptide functionalized with an azide was labeled with fac-[MI(CO)3]+ using both click, then chelate (CuAAC reaction with 1 or 3 followed by metal complexation) and chelate, then click (metal complexation of 1 and 3 followed by CuAAC with the peptide) strategies to assess the effects of CuAAC conditions on fac-[MI(CO)3]+ complexation within a peptide framework. The peptides from the click, then chelate strategy had different HPLC tR’s and in vitro stabilities compared to those from the chelate, then click strategy, suggesting nonspecific coordination of fac-[MI(CO)3]+ using this synthetic route. The fac-[MI(CO)3]+-complexed peptides from the chelate, then click strategy showed >90% stability during in vitro challenge conditions for 6 h, demonstrated high affinity and specificity for the melanocortin 1 receptor (MC1R) in IC50 analyses, and led to moderately high uptake in B16F10 melanoma cells. Log P analysis of the 99mTc

  9. Water-stable fac-{TcO₃}⁺ complexes - a new field of technetium chemistry.

    PubMed

    Braband, Henrik

    2011-01-01

    The development of technetium chemistry has been lagging behind that of its heavier congener rhenium, primarily because the inherent radioactivity of all Tc isotopes has limited the number of laboratories that can study the chemistry of this fascinating element. Although technetium is an artificial element, it is not rare. Significant amounts of the isotope (99)Tc are produced every day as a fission byproduct in nuclear power plants. Therefore, a fundamental understanding of the chemistry of (99)Tc is essential to avoid its release into the environment. In this article the chemistry of technetium at its highest oxidation state (+VII) is reviewed with a special focus on recent developments which make water-stable complexes of the general type [TcO(3)(tacn-R)](+) (tacn-R = 1,4,7-triazacyclononane or derivatives) accessible. Complexes containing the fac-{TcO(3)}(+) core display a unique reactivity. In analogy to [OsO(4)] and [RuO(4)], complexes containing the fac-{TcO(3)}(+) core undergo with alkenes metal-mediated, vicinal cis-dihydroxylation reactions (alkene-glycol interconversion) in water via a (3+2)-cycloaddition reaction. Therefore, water-stable fac-{(99m)TcO(3)}(+) complexes pave the way for a new labeling strategy for radiopharmaceutical applications, based on (3+2)-cycloaddition reactions. This new concept for the labeling of biomolecules with small [(99m)TcO(3)(tacn-R)](+)-type complexes by way of a (3+2)-cycloaddition with alkenes is discussed in detail. The herein reported developments in high-valent technetium chemistry create a new field of research with this artificial element. This demonstrates the potential of fundamental research to provide new impetus of innovation for the development of new methods for radiopharmaceutical applications.

  10. Olanzapine induced Q-Tc shortening.

    PubMed

    Shoja Shafti, Saeed; Fallah Jahromi, Parisa

    2014-12-01

    Prolongation of Q-Tc interval is commonly accepted as a surrogate marker for the ability of a drug to cause torsade de pointes. In the present study, safety of olanzapine versus risperidone was compared among a group of patients with schizophrenia to see the frequency of the electrocardiographic alterations induced by those atypical antipsychotics. Two hundred and sixty-eight female inpatients with schizophrenia entered in one of the two parallel groups to participate in an open study for random assignment to olanzapine (n = 148) or risperidone (n = 120). Standard 12-lead surface electrocardiogram (ECG) was taken from each patient at baseline, before initiation of treatment, and then at the end of management, just before discharge. The parameters that were assessed included heart rate (HR), P-R interval, QRS interval, Q-T interval (corrected = Q-Tc), ventricular activation time (VAT), ST segment, T wave, axis of QRS, and finally, interventricular conduction process. A total of 37.83% of cases in the olanzapine group and 30% in the risperidone group showed some Q-Tc changes; 13.51% and 24.32% of the patients in the olanzapine group showed prolongation and shortening of the Q-Tc, respectively, while changes in the risperidone group were restricted to only prolongation of Q-Tc. Comparison of means showed a significant increment in Q-Tc by risperidone (p = 0.02). Also, comparison of proportions in the olanzapine group showed significantly more cases with shortening of Q-Tc versus its prolongation (p = 0.01). No significant alterations with respect to other variables were evident. Olanzapine and risperidone had comparable potentiality for induction of Q-Tc changes, while production of further miscellaneous alterations in ECG was more observable in the olanzapine group compared with the risperidone group. Also shortening of Q-Tc was specific to olanzapine.

  11. Dose calibrator linearity test: 99mTc versus 18F radioisotopes*

    PubMed Central

    Willegaignon, José; Sapienza, Marcelo Tatit; Coura-Filho, George Barberio; Garcez, Alexandre Teles; Alves, Carlos Eduardo Gonzalez Ribeiro; Cardona, Marissa Anabel Rivera; Gutterres, Ricardo Fraga; Buchpiguel, Carlos Alberto

    2015-01-01

    Objective The present study was aimed at evaluating the viability of replacing 18F with 99mTc in dose calibrator linearity testing. Materials and Methods The test was performed with sources of 99mTc (62 GBq) and 18F (12 GBq) whose activities were measured up to values lower than 1 MBq. Ratios and deviations between experimental and theoretical 99mTc and 18F sources activities were calculated and subsequently compared. Results Mean deviations between experimental and theoretical 99mTc and 18F sources activities were 0.56 (± 1.79)% and 0.92 (± 1.19)%, respectively. The mean ratio between activities indicated by the device for the 99mTc source as measured with the equipment pre-calibrated to measure 99mTc and 18F was 3.42 (± 0.06), and for the 18F source this ratio was 3.39 (± 0.05), values considered constant over the measurement time. Conclusion The results of the linearity test using 99mTc were compatible with those obtained with the 18F source, indicating the viability of utilizing both radioisotopes in dose calibrator linearity testing. Such information in association with the high potential of radiation exposure and costs involved in 18F acquisition suggest 99mTc as the element of choice to perform dose calibrator linearity tests in centers that use 18F, without any detriment to the procedure as well as to the quality of the nuclear medicine service. PMID:25798005

  12. Monoanionic 99mTc-tricarbonyl-aminopolycarboxylate complexes with uncharged pendant groups: Radiosynthesis and evaluation as potential renal tubular tracers.

    PubMed

    Lipowska, Malgorzata; Klenc, Jeffrey; Jarkas, Nashwa; Marzilli, Luigi G; Taylor, Andrew T

    2017-04-01

    99m Tc(CO) 3 -nitrilotriacetic acid, 99m Tc(CO) 3 (NTA), is a new renal tubular agent with pharmacokinetic properties comparable to those of 131 I-OIH but the clearance of 99m Tc(CO) 3 (NTA) and 131 I-OIH is still less than the clearance of PAH, the gold standard for the measurement of effective renal plasma flow. At physiological pH, dianionic 99m Tc(CO) 3 (NTA) has a mononegative inner metal-coordination sphere and a mononegative uncoordinated carboxyl group. To evaluate alternate synthetic approaches, we assessed the importance of an uncoordinated carboxyl group, long considered essential for tubular transport, by evaluating the pharmacokinetics of three analogs with the 99m Tc(CO) 3 (NTA) metal-coordination sphere but with uncharged pendant groups. 99m Tc(CO) 3 complexes with N-(2-acetamido)iminodiacetic acid (ADA), N-(2-hydroxyethyl)iminodiacetic acid (HDA) and N-(fluoroethyl)iminodiacetic acid (FEDA) were prepared using a tricarbonyl kit and isolated by HPLC. The pharmacokinetics were evaluated in Sprague-Dawley rats, with 131 I-OIH as an internal control; urine was analyzed for metabolites. Plasma protein binding and erythrocyte uptake were determined from the 10min blood samples. Re(CO) 3 (FEDA), the analog of 99m Tc(CO) 3 (FEDA), was prepared and characterized. 99m Tc(CO) 3 (ADA), 99m Tc(CO) 3 (HDA) and 99m Tc(CO) 3 (FEDA) were efficiently prepared as a single species with high radiochemical purities (>99%). These new monoanionic 99m Tc(CO) 3 tracers with uncharged dangling groups all showed rapid blood clearance and high specificity for renal excretion. Activity in the urine, as a percent of 131 I-OIH at 10 and 60min, was 96% and 99% for ADA, 96% and 100% for HDA, and 100% and 99% for FEDA, respectively. Each new tracer was excreted unchanged in the urine. The Re(CO) 3 (FEDA) structure adds compelling evidence that such 99m Tc(CO) 3 (NTA) analogs have metal-coordination spheres identical to that of 99m Tc(CO) 3 (NTA). New tracers lacking the negatively

  13. Validation of a kinetic model for receptor-mediated uptake of Tc-99m-galactosyl-neoglycoalbumin (Tc-NGA)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vera, D.R.; Krohn, K.A.; Woodle, E.S.

    1984-01-01

    Tc-NGA is a receptor-binding radiopharmaceutical which localizes specifically to the liver. The rate of uptake depends upon: 1) Tc-NGA-receptor affinity, k/sub b/, 2) molar dose, L/sub e/(O), and 3) hepatic blood flow, Q. The authors have proposed a kinetic model which describes hepatic uptake in terms of measurable physiochemical quantities: Q, k/sub b/, R, V/sub e/, V/sub h/ (systemic and liver blood volumes), and V/sub r/ (liver plasma volume). Computer simulations were compared to kinetic data (ROIs: precordium and liver, 420 data pts) resulting from injection into pigs (n=12) of Tc-NGAs of differing k/sub b/(0.6,1.2,1.8 x 10/sup 5/ M/sup -1/sec/supmore » -1/). Each pig was studied twice using different molar doses (0.5 - 10. x 10/sup -8/mole). Measurements of V/sub e/ (Tc-RBCs) and Q (indocyanine green extraction) were obtained during each study. Weights of excised livers were used to calculate V/sub h/ and r. With exception of the low-dose, low-affinity studies, all data was fit to within a reduced chi-square of 3 by adjustment of 1/sub e/, 1/sub h/, c, ..cap alpha../sub m/ and the sigmas. The authors conclude that this model is a valid description of a receptor-binding process, however competition by endogenous ligand may prevent its use at low molar doses of low-k/sub b/ NGA.« less

  14. Association between the -455T>C promoter polymorphism of the APOC3 gene and the metabolic syndrome in a multi-ethnic sample.

    PubMed

    Pollex, Rebecca L; Ban, Matthew R; Young, T Kue; Bjerregaard, Peter; Anand, Sonia S; Yusuf, Salim; Zinman, Bernard; Harris, Stewart B; Hanley, Anthony J G; Connelly, Philip W; Huff, Murray W; Hegele, Robert A

    2007-12-20

    Common polymorphisms in the promoter of the APOC3 gene have been associated with hypertriglyceridemia and may impact on phenotypic expression of the metabolic syndrome (MetS). The rs7566605 marker, located near the INSIG2 gene, has been found to be associated with obesity, making it also a potential genetic determinant for MetS. The objective of this study is to examine the APOC3 -455T>C and the INSIG2 rs7566605 polymorphisms as potential genetic determinants for MetS in a multi-ethnic sample. Subjects were genotyped for both the APOC3 -455T>C and INSIG2 rs7566605 polymorphisms, and classified for the presence or absence of MetS (NCEP ATP III and IDF definitions). The total study population included 2675 subjects (> or =18 years of age) from six different geographical ancestries. For the overall study population, the prevalence of MetS was 22.6% (NCEP ATP III definition). Carriers of > or =1 copy of APOC3 -455C were more likely to have MetS (NCEP ATP III definition) than noncarriers (carrier odds ratio 1.73, 95% CI 1.40 to 2.14, adjusting for age and study group). The basis of the association was related not only to a higher proportion of -455C carriers meeting the triglyceride and high-density lipoprotein cholesterol criteria, but also the blood pressure criteria compared with wild-type homozygotes. Plasma apo C-III concentrations were not associated with APOC3 -455T>C genotype. The INSIG2 rs7566605 polymorphism was not associated with MetS or measures of obesity. Meta-analysis of the sample of multiple geographic ancestries indicated that the functional -455T>C promoter polymorphism in APOC3 was associated with an approximately 2-fold increased risk of MetS, whereas the INSIG2 rs7566605 polymorphism was not associated with MetS.

  15. Improved Quantification of the Beta Cell Mass after Pancreas Visualization with 99mTc-demobesin-4 and Beta Cell Imaging with 111In-exendin-3 in Rodents.

    PubMed

    van der Kroon, Inge; Joosten, Lieke; Nock, Berthold A; Maina, Theodosia; Boerman, Otto C; Brom, Maarten; Gotthardt, Martin

    2016-10-03

    Accurate assessment of the 111 In-exendin-3 uptake within the pancreas requires exact delineation of the pancreas, which is highly challenging by MRI and CT in rodents. In this study, the pancreatic tracer 99m Tc-demobesin-4 was evaluated for accurate delineation of the pancreas to be able to accurately quantify 111 In-exendin-3 uptake within the pancreas. Healthy and alloxan-induced diabetic Brown Norway rats were injected with the pancreatic tracer 99m Tc-demobesin-4 ([ 99m Tc-N 4 -Pro 1 ,Tyr 4 ,Nle 14 ]bombesin) and the beta cell tracer 111 In-exendin-3 ([ 111 In-DTPA-Lys 40 ]exendin-3). After dual isotope acquisition of SPECT images, 99m Tc-demobesin-4 was used to define a volume of interest for the pancreas in SPECT images subsequently the 111 In-exendin-3 uptake within this region was quantified. Furthermore, biodistribution and autoradiography were performed in order to gain insight in the distribution of both tracers in the animals. 99m Tc-demobesin-4 showed high accumulation in the pancreas. The uptake was highly homogeneous throughout the pancreas, independent of diabetic status, as demonstrated by autoradiography, whereas 111 In-exendin-3 only accumulates in the islets of Langerhans. Quantification of both ex vivo and in vivo SPECT images resulted in an excellent linear correlation between the pancreatic uptake, determined with ex vivo counting and 111 In-exendin-3 uptake, determined from the quantitative analysis of the SPECT images (Pearson r = 0.97, Pearson r = 0.92). 99m Tc-demobesin-4 shows high accumulation in the pancreas of rats. It is a suitable tracer for accurate delineation of the pancreas and can be conveniently used for simultaneous acquisition with 111 In labeled exendin-3. This method provides a straightforward, reliable, and objective method for preclinical beta cell mass (BCM) quantification with 111 In-exendin-3.

  16. Multiband full-bandwidth anisotropic Eliashberg theory of interfacial electron-phonon coupling and high - Tc superconductivity in FeSe /SrTiO3

    NASA Astrophysics Data System (ADS)

    Aperis, Alex; Oppeneer, Peter M.

    2018-02-01

    We examine the impact of interfacial phonons on the superconducting state of FeSe /SrTiO3 developing a material's specific multiband, full bandwidth, and anisotropic Eliashberg theory for this system. Our self-consistent calculations highlight the importance of the interfacial electron-phonon interaction, which is hidden behind the seemingly weak-coupling constant λm=0.4 , in mediating the high Tc, and explain other puzzling experimental observations, such as the s -wave symmetry and replica bands. We discover that the formation of replica bands has a Tc decreasing effect that is nevertheless compensated by deep Fermi-sea Cooper pairing which has a Tc enhancing effect. We predict a strong-coupling dip-hump signature in the tunneling spectra due to the interfacial coupling.

  17. 99mTc-EDDA/HYNIC-Tyr(3)-octreotide for staging and follow-up of patients with neuroendocrine gastro-entero-pancreatic tumors.

    PubMed

    Gabriel, M; Muehllechner, P; Decristoforo, C; von Guggenberg, E; Kendler, D; Prommegger, R; Profanter, C; Moncayo, R; Virgolini, I

    2005-09-01

    To evaluate the use of 99mTc-EDDA-hydrazinonicotinyl-Tyr3-octreotide (Tc-TOC) for staging and follow-up of neuroendocrine gastro-entero-pancreatic (GEP) tumors with special focus on the acquisition protocol including single photon emission computed tomography (SPECT). Eighty-eight patients (37 female, 51 male; age range: 16 to 81 years; mean age: 56.3 years) were studied: 42 patients for staging after initial histological confirmation and 46 patients during post-therapy follow-up. An average activity of 400 MBq of the radiopharmaceutical was injected. All tumors originated from neuroendocrine tissue of the gastroenteropancreatic tract. Whole body scintigrams at 4 h postinjection and SPECT of the abdomen were obtained in all patients. Additional planar images of the abdomen were acquired at 2 h after injection in 68 patients. The Tc-TOC scan result was true-positive in 56 patients, true-negative in 17, false-negative in 14, and false-positive in 1 patient. The false-positive finding was caused by a colonic adenoma. Overall, a scan sensitivity of 80% (56/70 patients), specificity of 94.4% (17/18 patients) and accuracy of 82.9% (73/88 patients) were calculated on patient basis. In total, Tc-TOC detected 357 foci in 69 patients. In 7 patients equivocal findings were observed in the bowel at 4 h postinjection without corresponding tracer uptake in the scan 2 h earlier, meaning that these abnormal findings were correctly classified as non-malignant. In addition to planar views, SPECT revealed further 62 lesions. Tc-TOC with one-day, dual-time acquisition protocol is an accurate staging procedure in patients with neuroendocrine GEP tumors. SPECT shows high sensitivity for detection of abdominal lesions, while earlier images improve the reliability of abnormal abdominal findings.

  18. A Diffraction-limited Survey for Direct Detection of Halpha Emitting/Accreting ExtraSolar Planets with the 6.5m Magellan Telescope and the MagAO Visible AO system

    NASA Astrophysics Data System (ADS)

    Close, Laird

    TECHNICAL BACKGROUND: An advanced adaptive secondary mirror (ASM) with 585 actuators was commissioned at the 6.5-m Magellan Telescope at one of the world’s best sites (Las Campanas Observatory; LCO) in Chile. By the end of the commissioning run (April 2013) the MagAO system was regularly producing the highest spatial resolution deep images to date (0.023” deep images at Halpha (0.656 microns); Close et al. 2013). This is due to its 378 corrective modes at 1kHz on a 6.5-m telescope. Strehl ratis>20% at Halpha were obtained in 75% of the seeing statistics at the site. We propose here to utilize MagAO’s absolutely unique ability to take Halpha, continuum (0.643 microns), and L’ (3.8 microns) thermal images (all simultaneously) to carry out a novel survey to: Discover a population of the lowest mass young accreting extrasolar planets imaged to date. to characterize the spatial distribution, and estimate accretion rates, of young extrasolar planets >5AU, to understand the influence of planets on transitional disk gaps. THEORY BACKGROUND: Extrasolar planets are very difficult to image directly since planets become very faint below ~8 Mjup (Jupiter masses) for ages >1 Myr and such massive planets are rare. There is a class of young stars that are still accreting yet have SED (and often imaging) evidence of a lack of dust and gas inside a r=5-140 AU “gap”. These “transitional disks” are believed to be transitioning into “disk free” stars. These gaps are believed to be maintained by planets that continuously clear (though scattering or accretion) the optically thin gaps. Indeed large >10 AU gaps (>few Hill spheres) must be maintained by multiple ~1 Mjup planets (Dodson-Robinson & Salyk 2011). Since gas must pass through each of these gaps to continuously supply the accreting star, simulations suggest that these “gap planets” are also crossing points for these gas streamers on their way to the star. These streamers “force-feed” these planets a

  19. Identification of Yju3p as functional orthologue of mammalian monoglyceride lipase in the yeast Saccharomycescerevisiae.

    PubMed

    Heier, Christoph; Taschler, Ulrike; Rengachari, Srinivasan; Oberer, Monika; Wolinski, Heimo; Natter, Klaus; Kohlwein, Sepp D; Leber, Regina; Zimmermann, Robert

    2010-09-01

    Monoacylglycerols (MAGs) are short-lived intermediates of glycerolipid metabolism. Specific molecular species, such as 2-arachidonoylglycerol, which is a potent activator of cannabinoid receptors, may also function as lipid signaling molecules. In mammals, enzymes hydrolyzing MAG to glycerol and fatty acids, resembling the final step in lipolysis, or esterifying MAG to diacylglycerol, are well known; however, despite the high level of conservation of lipolysis, the corresponding activities in yeast have not been characterized yet. Here we provide evidence that the protein Yju3p functions as a potent MAG hydrolase in yeast. Cellular MAG hydrolase activity was decreased by more than 90% in extracts of Yju3p-deficient cells, indicating that Yju3p accounts for the vast majority of this activity in yeast. Loss of this activity was restored by heterologous expression of murine monoglyceride lipase (MGL). Since yju3Delta mutants accumulated MAG in vivo only at very low concentrations, we considered the possibility that MAGs are re-esterified into DAG by acyltransferases. Indeed, cellular MAG levels were further increased in mutant cells lacking Yju3p and Dga1p or Lro1p acyltransferase activities. In conclusion, our studies suggest that catabolic and anabolic reactions affect cellular MAG levels. Yju3p is the functional orthologue of mammalian MGL and is required for efficient degradation of MAG in yeast. 2010 Elsevier B.V. All rights reserved.

  20. Identification of Yju3p as functional orthologue of mammalian monoglyceride lipase in the yeast Saccharomycescerevisiae

    PubMed Central

    Heier, Christoph; Taschler, Ulrike; Rengachari, Srinivasan; Oberer, Monika; Wolinski, Heimo; Natter, Klaus; Kohlwein, Sepp D.; Leber, Regina; Zimmermann, Robert

    2010-01-01

    Monoacylglycerols (MAGs) are short-lived intermediates of glycerolipid metabolism. Specific molecular species, such as 2-arachidonoylglycerol, which is a potent activator of cannabinoid receptors, may also function as lipid signaling molecules. In mammals, enzymes hydrolyzing MAG to glycerol and fatty acids, resembling the final step in lipolysis, or esterifying MAG to diacylglycerol, are well known; however, despite the high level of conservation of lipolysis, the corresponding activities in yeast have not been characterized yet. Here we provide evidence that the protein Yju3p functions as a potent MAG hydrolase in yeast. Cellular MAG hydrolase activity was decreased by more than 90% in extracts of Yju3p-deficient cells, indicating that Yju3p accounts for the vast majority of this activity in yeast. Loss of this activity was restored by heterologous expression of murine monoglyceride lipase (MGL). Since yju3Δ mutants accumulated MAG in vivo only at very low concentrations, we considered the possibility that MAGs are re-esterified into DAG by acyltransferases. Indeed, cellular MAG levels were further increased in mutant cells lacking Yju3p and Dga1p or Lro1p acyltransferase activities. In conclusion, our studies suggest that catabolic and anabolic reactions affect cellular MAG levels. Yju3p is the functional orthologue of mammalian MGL and is required for efficient degradation of MAG in yeast. PMID:20554061

  1. H-modulated microwave absorption and resistive transition in the high- Tc superconductor YBa 2Cu 3O 7

    NASA Astrophysics Data System (ADS)

    Buluggiu, E.; Vera, A.; Amoretti, G.

    1990-11-01

    The derivative microwave absorption near Tc in presence of a sufficiently high field ( H⩾1 kOe) is related to the temperature variation of resistivity. This idea, originally proposed by Kim et al. (1988), is extended to take into account the effects of the anomalous resistive tail by using the thermoactivated flux-creep model proposed by Tinkham (1988). This gives a simple explanation for some relevant features observed in the temperature behaviour of the ESR absorption, as the asymmetry of the peak at Tc, with the long tail extending toward low temperatures, and the field dependence of height and linewidth, for which the model provides H-1 and H2/3 behaviour, respectively, ESR data on YBa 2Cu 3O 7 powder are in satisfactory agreement with this picture, when the role of the intrinsic 2D-character of this compound is properly taken into account. This allows us to deduce consistent values for the parameters a‖ and a⊥ of the anisotropic resistivity.

  2. MagIC, a genetically encoded fluorescent indicator for monitoring cellular Mg2+ using a non-Förster resonance energy transfer ratiometric imaging approach

    NASA Astrophysics Data System (ADS)

    Koldenkova, Vadim Pérez; Matsuda, Tomoki; Nagai, Takeharu

    2015-10-01

    Intracellular Mg roles are commensurate with its abundance in the cell cytoplasm. However, little is known about Mg subcellular dynamics, primarily due to the lack of suitable Mg-selective tools to monitor this ion in intracellular compartments. To cope with this lack, we developed a Mg-sensitive indicator-MagIC (indicator for Magnesium Imaging in Cell) -composed of a functionalized yellow fluorescent protein (FP) variant fused to a red-emitting FP serving as a reference, thus allowing ratiometric imaging of Mg. MagIC expressed in mammalian cells is homogeneously distributed between the cytosol and nucleus but its fusion with appropriate targeting sequences redirects it to mitochondria or the endoplasmic reticulum. MagIC shows little interference by intracellular Ca [Kd(Mg2+)=5.1 mM Kd(Ca2+)=4.8 mM] and its kinetic properties (k=84 s-1) approach those of indicator dyes. With MagIC, as reported previously, we also observed a cytosolic Mg increase provoked by application of 50 mM MgCl2 in the medium. This effect is, however, mimicked by 75 mM KCl or 150 mM D-sorbitol addition, indicating that it is a response to the associated hyperosmotic shock and not to Mg itself. Our results confirm the functionality of MagIC as a useful tool for the long-awaited possibility of prolonged and organelle-specific monitoring of cellular Mg.

  3. Effects of FlAsH/Tetracysteine (TC) tag on PrP proteolysis and PrPres formation by TC-scanning

    PubMed Central

    Taguchi, Yuzuru; Hohsfield, Lindsay A.; Hollister, Jason R.

    2014-01-01

    The FlAsH/tetracysteine (FlAsH/TC) tag is a powerful tool for fluorescent labeling of proteins. However, even small tags such as FlAsH/TC could alter the behavior of the tagged proteins, especially if the insertion occurs at internal sites. Defining the influence of FlAsH/TC on nearby protein-protein interactions might aid in selecting appropriate positions for internal TC insertions and allow the exploitation of serial FlAsH/TC insertions (TC-scanning) as a probe to characterize sites of protein-protein interaction. To explore this application in the context of substrate-protease interactions, we analyzed the effect of FlAsH/TC insertions on proteolysis of cellular prion protein (PrPsen) in in vitro reactions and generation of the C1 metabolic fragment of PrPsen in live neuroblastoma cells. The influence of FlAsH/TC insertion was evaluated by TC-scanning across the cleavage sites of each protease. The results showed that FlAsH/TC inhibited protease cleavage only within limited ranges of the cleavage sites that varied from about 1 to 6 residues-wide depending on the protease, providing an estimate of the PrP residues interacting with each protease. TC-scanning was also used to probe a different type of protein-protein interaction, the conformational conversion of FlAsH-PrPsen to the prion disease-associated isoform, PrPres. PrP constructs with FlAsH/TC insertions at residues 90–96 but not 97–101 were converted to FlAsH-PrPres, identifying a boundary separating loosely versus compactly folded regions of PrPres. Our observations demonstrate that TC-scanning with the FlAsH/TC tag can be a versatile method for probing protein-protein interactions and folding processes. PMID:23943295

  4. Uniaxial strain orientation dependence of superconducting transition temperature (Tc) and critical superconducting pressure (Pc) in β-(BDA-TTP)2I3.

    PubMed

    Kikuchi, Koichi; Isono, Takayuki; Kojima, Masayuki; Yoshimoto, Haruo; Kodama, Takeshi; Fujita, Wataru; Yokogawa, Keiichi; Yoshino, Harukazu; Murata, Keizo; Kaihatsu, Takayuki; Akutsu, Hiroki; Yamada, Jun-ichi

    2011-12-14

    Dependence of the superconducting transition temperature (T(c)) and critial superconducting pressure (P(c)) of the pressure-induced superconductor β-(BDA-TTP)(2)I(3) [BDA-TTP = 2,5-bis(1,3-dithian-2-ylidene)-1,3,4,6-tetrathiapentalene] on the orientation of uniaxial strain has been investigated. On the basis of the overlap between the upper and lower bands in the energy dispersion curve, the pressure orientation is thought to change the half-filled band to the quarter-filled one. The observed variations in T(c) and P(c) are explained by considering the degree of application of the pressure and the degree of contribution of the effective electronic correlation at uniaxial strains with different orientations parallel to the conducting donor layer. © 2011 American Chemical Society

  5. Vibrational spectra and lattice instabilities in the high-Tc superconductors YBa2Cu3O7 and GdBa2Cu3O7

    NASA Astrophysics Data System (ADS)

    Bozović, I.; Mitzi, D.; Beasley, M.; Kapitulnik, A.; Geballe, T.; Perkowitz, S.; Carr, G. L.; Lou, B.; Sudharsanan, R.; Yom, S. S.

    1987-09-01

    The exceptionally high Tc of layered cuprates was proposed recently as originating from electronically driven structural instabilities. We have studied the infrared and Raman spectra of YBa2Cu3O7-δ and GdBa2Cu3O7-δ over a broad range of temperatures, from 10 to 300 K. We observed neither mode softening nor any other spectroscopic signature of lattice instabilities.

  6. Telecom 2-B and 2-C (TC2B and TC2C)

    NASA Technical Reports Server (NTRS)

    Dulac, J.; Alvarez, H.

    1991-01-01

    The DSN (Deep Space Network) mission support requirements for Telecom 2-B and 2-C (TC2B and TC2C) are summarized. These Telecom missions will provide high-speed data link applications, telephone, and television service between France and overseas territories as a follow-on to TC2A. Mission objectives are outlined and the DSN support requirements are defined through the presentation of tables and narratives describing the spacecraft flight profile; DSN support coverage; frequency assignments; support parameters for telemetry, command and support systems; and tracking support responsibility.

  7. Tricine co-ligand improved the efficacy of 99mTc-HYNIC-(Ser)3-J18 peptide for targeting and imaging of non-small-cell lung cancer.

    PubMed

    Shaghaghi, Zahra; Abedi, Seyed Mohammad; Hosseinimehr, Seyed Jalal

    2018-05-15

    The early diagnosis of non-small cell lung cancer (NSCLC) is important for increasing survival rate and improving quality life of patients. The aim of this study was to investigate 99m  Tc-(tricine)-HYNIC-(Ser) 3 -J18 for targeting and imaging of NSCLC in A-549 xenografted nude mice. The (Ser) 3 -J18 peptide was conjugated with HYNIC and labeled with 99m  Tc using tricine as a co-ligand. The radiolabeled peptide was evaluated for its radiochemical purity, stability, receptor binding and internalization in vitro. The future experiments were performed for tumor targeting and imaging in A-549 tumor-bearing mice. 99m  Tc-(tricine)-HYNIC-(Ser) 3 -J18 was obtained at high labeling efficiency at room temperature and favorable stability in saline and human plasma. At the cellular level, the radiolabeled peptide specifically bond to A-549 cells with a K D 4.1 ± 1.3 nM. Biodistribution study revealed tumor to blood and tumor to muscle ratios were about 3.12 and 5.63 respectively after 2 h injection of radiolabeled peptide. These ratios were significantly decreased by co-injection of excess non-labeled peptide in mice. This radiolabeled peptide selectively targeted to NSCLC tumor and exhibited a high target uptake combined with acceptable low background activity for tumor imaging in mice. The results of this study and its comparison with another study showed that 99m  Tc-(tricine)-HYNIC-(Ser) 3 -J18 is better than previously reported radiolabeled peptide as 99m  Tc-(EDDA/tricine)-HYNIC-(Ser) 3 -J18 for NSCLC targeting and imaging. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  8. (99) Tc-methylene diphosphonate improves rheumatoid arthritis disease activity by increasing the frequency of peripheral γδ T cells and CD4(+) CD25(+) Foxp3(+) Tregs.

    PubMed

    Su, Dinglei; Shen, Minning; Gu, Bingjie; Wang, Xiaoqin; Wang, Dandan; Li, Xia; Sun, Lingyun

    2016-06-01

    γδ T cells exhibit important functions in the pathogenesis of rheumatoid arthritis (RA). In recent years, numerous studies harnessed the γδ T cell-activating capacity of aminobiphosphonates for the treatment of malignant tumors. As (99) Tc-methylene diphosphonate ((99) Tc-MDP) has long been widely used for the treatment of RA in China with good efficacy, we are interested in whether this drug exerts its therapeutic effect on RA by modulating peripheral γδ T cells of RA patients. To investigate the effect of (99) Tc-MDP on the frequency of γδ T cells and CD4(+) CD25(+) Foxp3(+) Tregs in the peripheral blood of patients with active RA. Nineteen patients with active RA were treated with (99) Tc-MDP intravenously at a dose of 20 μg/day consecutively for 10-14 days. Before and after treatment, the main clinical and laboratory parameters for each patient were evaluated. The frequency of CD3(+) γδ(+) T cells and CD4(+) CD25(+) Foxp3(+) Tregs was detected by flow cytometry. Serum levels of interferon (IFN)-γ, tumor necrosis factor (TNF)-α, interleukin (IL)-6, IL-10 and transforming growth factor (TGF)-β were measured with enzyme-linked immunosorbent assay. After intravenous (99) Tc-MDP therapy, the frequency of peripheral CD3(+) γδ(+) T cells and CD4(+) CD25(+) Foxp3(+) Tregs were significantly elevated, paralleled with decreased serum levels of TNF-α and IL-6 and increased level of serum TGF-β. The elevation of peripheral CD3(+) γδ(+) T cells was positively correlated with increased serum TGF-β and decreased disease activity. (99) Tc-MDP may improve the activity of RA through upregulating the frequency of peripheral γδ T cells and CD4(+) CD25(+) Foxp3(+) Tregs as well as affecting the serum cytokine environment by increasing TGF-β and decreasing TNF-α and IL-6. © 2014 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.

  9. Computed Tomography Volumetry in Preoperative Living Kidney Donor Assessment for Prediction of Split Renal Function.

    PubMed

    Wahba, Roger; Franke, Mareike; Hellmich, Martin; Kleinert, Robert; Cingöz, Tülay; Schmidt, Matthias C; Stippel, Dirk L; Bangard, Christopher

    2016-06-01

    Transplant centers commonly evaluate split renal function (SRF) with Tc-99m-mercapto-acetyltriglycin (MAG3) scintigraphy in living kidney donation. Alternatively, the kidney volume can be measured based on predonation CT scans. The aim of this study was to identify the most accurate CT volumetry technique for SRF and the prediction of postdonation kidney function (PDKF). Three CT volumetry techniques (modified ellipsoid volume [MELV], smart region of interest [ROI] volume, renal cortex volume [RCV]) were performed in 101 living kidney donors. Preoperation CT volumetric SRF was determined and compared with MAG3-SRF, postoperation donor kidney function, and graft function. The correlation between donors predonation total kidney volume and predonation kidney function was the highest for RCV (0.58 with creatine clearance, 0.54 with estimated glomerular filtration rate-Cockcroft-Gault). The predonation volume of the preserved kidney was (ROI, MELV, RCV) 148.0 ± 29.1 cm, 151.2 ± 35.4 and 93.9 ± 25.2 (P < 0.005 MELV vs RCV and ROI vs RCV). Bland-Altman analysis showed agreement between CT volumetry SRF and MAG3-SRF (bias, 95% limits of agreement: ROI vs MAG3 0.4%, -7.7% to 8.6%; MELV vs MAG3 0.4%, -8.9% to 9.7%; RCV vs MAG3 0.8%, -9.1% to 10.7%). The correlation between predonation CT volumetric SRF of the preserved kidney and PDKF at day 3 was r = 0.85 to 0.88, between MAG3-SRF and PDKF (r = 0.84). The difference of predonation SRF between preserved and donated kidney was the lowest for ROI and RCV (median, 3% and 4%; 95th percentile, 9% and 13%). Overall renal cortex volumetry seems to be the most accurate technique for the evaluation of predonation SRF and allows a reliable prediction of donor's PDKF.

  10. Clickable, hydrophilic ligand for fac-[M(I)(CO)3](+) (M = Re/(99m)Tc) applied in an S-functionalized α-MSH peptide.

    PubMed

    Kasten, Benjamin B; Ma, Xiaowei; Liu, Hongguang; Hayes, Thomas R; Barnes, Charles L; Qi, Shibo; Cheng, Kai; Bottorff, Shalina C; Slocumb, Winston S; Wang, Jing; Cheng, Zhen; Benny, Paul D

    2014-03-19

    The copper(I)-catalyzed azide-alkyne cycloaddition (CuAAC) click reaction was used to incorporate alkyne-functionalized dipicolylamine (DPA) ligands (1 and 3) for fac-[M(I)(CO)3](+) (M = Re/(99m)Tc) complexation into an α-melanocyte stimulating hormone (α-MSH) peptide analogue. A novel DPA ligand with carboxylate substitutions on the pyridyl rings (3) was designed to increase the hydrophilicity and to decrease in vivo hepatobiliary retention of fac-[(99m)Tc(I)(CO)3](+) complexes used in single photon emission computed tomography (SPECT) imaging studies with targeting biomolecules. The fac-[Re(I)(CO)3(3)] complex (4) was used for chemical characterization and X-ray crystal analysis prior to radiolabeling studies between 3 and fac-[(99m)Tc(I)(OH2)3(CO)3](+). The corresponding (99m)Tc complex (4a) was obtained in high radiochemical yields, was stable in vitro for 24 h during amino acid challenge and serum stability assays, and showed increased hydrophilicity by log P analysis compared to an analogous complex with nonfunctionalized pyridine rings (2a). An α-MSH peptide functionalized with an azide was labeled with fac-[M(I)(CO)3](+) using both click, then chelate (CuAAC reaction with 1 or 3 followed by metal complexation) and chelate, then click (metal complexation of 1 and 3 followed by CuAAC with the peptide) strategies to assess the effects of CuAAC conditions on fac-[M(I)(CO)3](+) complexation within a peptide framework. The peptides from the click, then chelate strategy had different HPLC tR's and in vitro stabilities compared to those from the chelate, then click strategy, suggesting nonspecific coordination of fac-[M(I)(CO)3](+) using this synthetic route. The fac-[M(I)(CO)3](+)-complexed peptides from the chelate, then click strategy showed >90% stability during in vitro challenge conditions for 6 h, demonstrated high affinity and specificity for the melanocortin 1 receptor (MC1R) in IC50 analyses, and led to moderately high uptake in B16F10 melanoma cells

  11. Comparison of Tc-99m maraciclatide and Tc-99m sestamibi molecular breast imaging in patients with suspected breast cancer.

    PubMed

    O'Connor, Michael K; Morrow, Melissa M B; Hunt, Katie N; Boughey, Judy C; Wahner-Roedler, Dietlind L; Conners, Amy Lynn; Rhodes, Deborah J; Hruska, Carrie B

    2017-12-01

    Molecular breast imaging (MBI) performed with 99m Tc sestamibi has been shown to be a valuable technique for the detection of breast cancer. Alternative radiotracers such as 99m Tc maraciclatide may offer improved uptake in breast lesions. The purpose of this study was to compare relative performance of 99m Tc sestamibi and 99m Tc maraciclatide in patients with suspected breast cancer, using a high-resolution dedicated gamma camera for MBI. Women with breast lesions suspicious for malignancy were recruited to undergo two MBI examinations-one with 99m Tc sestamibi and one with 99m Tc maraciclatide. A radiologist interpreted MBI studies in a randomized, blinded fashion to assign an assessment score (1-5) and measured lesion size. Lesion-to-background (L/B) ratio was measured with region-of-interest analysis. Among 39 analyzable patients, 21 malignant tumors were identified in 21 patients. Eighteen of 21 tumors (86%) were seen on 99m Tc sestamibi MBI and 19 of 21 (90%) were seen on 99m Tc maraciclatide MBI (p = 1). Tumor extent measured with both radiopharmaceuticals correlated strongly with pathologic size ( 99m Tc sestamibi, r = 0.84; 99m Tc maraciclatide, r = 0.81). The L/B ratio in detected breast cancers was similar for the two radiopharmaceuticals: 1.55 ± 0.36 (mean ± S.D.) for 99m Tc sestamibi and 1.62 ± 0.37 (mean ± S.D.) for 99m Tc maraciclatide (p = 0.53). No correlation was found between the L/B ratio and molecular subtype for 99m Tc sestamibi (r s  = 0.12, p = 0.63) or 99m Tc maraciclatide (r s  = -0.12, p = 0.64). Of 20 benign lesions, 10 (50%) were seen on 99m Tc sestamibi and 9 of 20 (45%) were seen on 99m Tc maraciclatide images (p = 0.1). The average L/B ratio for benign lesions was 1.34 ±0.40 (mean ±S.D.) for 99m Tc sestamibi and 1.41 ±0.52 (mean ±S.D.) for 99m Tc maraciclatide (p = 0.75). Overall diagnostic performance was similar for both radiopharmaceuticals. AUC from ROC

  12. Pharmacokinetics of 99mTc-MAA- and 99mTc-HSA-Microspheres Used in Preradioembolization Dosimetry: Influence on the Liver-Lung Shunt.

    PubMed

    Grosser, Oliver S; Ruf, Juri; Kupitz, Dennis; Pethe, Annette; Ulrich, Gerhard; Genseke, Philipp; Mohnike, Konrad; Pech, Maciej; Richter, Wolf S; Ricke, Jens; Amthauer, Holger

    2016-06-01

    Perfusion scintigraphy using (99m)Tc-labeled albumin aggregates is mandatory before hepatic radioembolization with (90)Y-microspheres. As part of a prospective trial, the intrahepatic and intrapulmonary stability of 2 albumin compounds, (99m)Tc-MAA (macroaggregated serum albumin [MAA]) and (99m)Tc-HSA (human serum albumin [HSA]), was assessed. In 24 patients with metastatic colorectal cancer, biodistribution (liver, lung) and liver-lung shunt (LLS) of both tracers (12 patients each) were assessed by sequential planar scintigraphy (1, 5, and 24 h after injection). Liver uptake of both albumin compounds decreased differently. Although initial LLSs at 1 h after injection were similar in both groups, MAA-LLS increased significantly from 1 (3.9%) to 5 h (7.7%) and 24 h (9.9%) after injection, respectively. HSA-LLS did not change significantly (1 to 5 h), indicating a steady state of pulmonary and intrahepatic degradation. Compared with (99m)Tc-MAA-microspheres, (99m)Tc-HSA-microspheres are likely more resistant to degradation over time, allowing a reliable LLS determination even at later time points. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  13. Imaging of irradiated liver with Tc-99m-sulfur colloid and Tc-99m-IDA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gelfand, M.J.; Saha, S.; Aron, B.S.

    1981-09-01

    In three cases, irradiated regions of liver failed to concentrate Tc-99m-sulfur colloid. In two of these three, imaging with Tc-99m-acetanilide iminodiacetic acid (IDA) agents within five days showed near normal hepatic uptake of this hepatobiliary imaging agent. The hepatic parenchymal cells may be imaged with Tc-99m-IDA in some irradiated regions of liver, despite loss of reticuloendothelial cell function.

  14. Amyloidosis of heart and liver: comparison of Tc-99m pyrophosphate and Tc-99m methylene diphosphonate for detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, V.W.; Caldarone, A.G.; Falk, R.H.

    1983-07-01

    A prospective, comparative study was made of the efficacy of technetium-99m pyrophosphate (Tc PYP) and technetium-99m methylene diphosphonate (Tc MDP) in detecting soft-tissue amyloidois. Tc PYP and Tc MDP scans were obtained within ten-day intervals in seven patients with histologically proven amyloidosis. Tc PYP was a better scanning agent for soft-tissue amyloidosis in all patients. Cardiac and hepatic involvement were proved by autopsy in one patient. Involvement of the heart was confirmed by echocardiography in five patients. The potential use of tc PYP scannning as a screening test for soft-tissue amyloidosis is discussed.

  15. Applicability of plasmid calibrant pTC1507 in quantification of TC1507 maize: an interlaboratory study.

    PubMed

    Meng, Yanan; Liu, Xin; Wang, Shu; Zhang, Dabing; Yang, Litao

    2012-01-11

    To enforce the labeling regulations of genetically modified organisms (GMOs), the application of DNA plasmids as calibrants is becoming essential for the practical quantification of GMOs. This study reports the construction of plasmid pTC1507 for a quantification assay of genetically modified (GM) maize TC1507 and the collaborative ring trial in international validation of its applicability as a plasmid calibrant. pTC1507 includes one event-specific sequence of TC1507 maize and one unique sequence of maize endogenous gene zSSIIb. A total of eight GMO detection laboratories worldwide were invited to join the validation process, and test results were returned from all eight participants. Statistical analysis of the returned results showed that real-time PCR assays using pTC1507 as calibrant in both GM event-specific and endogenous gene quantifications had high PCR efficiency (ranging from 0.80 to 1.15) and good linearity (ranging from 0.9921 to 0.9998). In a quantification assay of five blind samples, the bias between the test values and true values ranged from 2.6 to 24.9%. All results indicated that the developed pTC1507 plasmid is applicable for the quantitative analysis of TC1507 maize and can be used as a suitable substitute for dried powder certified reference materials (CRMs).

  16. Oxidative Stability of Tc(I) Tricarbonyl Species Relevant to the Hanford Tank Waste

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chatterjee, Sayandev; Hall, Gabriel B.; Levitskaia, Tatiana G.

    Technetium (Tc), which exists predominately in the liquid supernatant and salt cake fractions of the nuclear tank waste stored at the U.S. DOE Hanford Site, is one of the most difficult contaminants to dispose of and/or remediate. In the strongly alkaline environments prevalent in the tank waste, its dominant chemical form is pertechnetate (TcO 4 -, oxidation state +7). However, based on experimentation to-date, a significant fraction of the soluble Tc cannot be effectively separated from the wastes and may be present as a non-pertechnetate species. The presence of a non pertechnetate species significantly complicates disposition of low-activity waste (LAW),more » and the development of methods to either convert them to pertechnetate or to separate the non-pertechnetate species directly is needed. The challenge is the uncertainty regarding the nature and stability of the alkaline-soluble, low-valence, non pertechnetate species in the liquid tank waste. One objective of the Tc management project is to address this knowledge gap. This fiscal year (FY) 2015 report summarizes experimental work exploring the oxidative stability of model low-valence Tc(I) tricarbonyl species, derived from the [Tc(CO) 3] + moiety. These compounds are of interest due to their implied presence in several Hanford tank waste supernatants. Work in part was initiated in FY 2014, and a series of samples containing non-pertechnetate Tc generated ex situ or in situ in pseudo-Hanford tank supernatant simulant solutions was prepared and monitored for oxidation to Tc(VII) (Levitskaia et al. 2014). This experimentation continued in FY 2015, and new series of samples containing Tc(I) as [Tc(CO) 3] +•Ligand was tested. The monitoring method used for these studies was a combination of 99Tc NMR and EPR spectroscopies.« less

  17. Comparison of Biological Properties of 99mTc-Labeled Cyclic RGD Peptide Trimer and Dimer Useful as SPECT Radiotracers for Tumor Imaging

    PubMed Central

    Zhao, Zuo-Quan; Yang, Yong; Fang, Wei; Liu, Shuang

    2016-01-01

    Introduction This study sought to evaluate a 99mTc-labeled trimeric cyclic RGD peptide (99mTc-4P-RGD3) as the new radiotracer for tumor imaging. The objective was to compare its biological properties with those of 99mTc-3P-RGD2 in the same animal model. Methods HYNIC-4P-RGD3 was prepared by reacting 4P-RGD3 with excess HYNIC-OSu in the presence of diisopropylethylamine. 99mTc-4P-RGD3 was prepared using a kit formulation, and evaluated for its tumor-targeting capability and biodistribution properties in the BALB/c nude mice with U87MG human glioma xenografts. Planar and SPECT imaging studies were performed in athymic nude mice with U87MG glioma xenografts. For comparison purpose, 99mTc-3P-RGD2 (a αvβ3-targeted radiotracer currently under clinical evaluation for tumor imaging in cancer patients) was also evaluated in the same animal models. Blocking experiments were used to demonstrate the αvβ3 specificity of 99mTc-4P-RGD3. Results 99mTc-4P-RGD3 was prepared with >95% RCP and high specific activity (~200 GBq/µmol). 99mTc-4P-RGD3 and 99mTc-3P-RGD2 shared almost identical tumor uptake and similar biodistribution properties. 99mTc-4P-RGD3 had higher uptake than 99mTc-3P-RGD2 in the intestines and kidneys; but it showed better metabolic stability. The U87MG tumors were clearly visualized by SPECT with excellent contrast with 99mTc-4P-RGD3 and 99mTc-3P-RGD2. Conclusion Increasing peptide multiplicity from 3P-RGD2 to 4P-RGD3 offers no advantages with respect to the tumor-targeting capability. 99mTc-4P-RGD3 is as good a SPECT radiotracer as 99mTc-3P-RGD2 for imaging αvβ3-positive tumors. PMID:27556955

  18. Stability of stabilized 99mTc-D,L-HMPAO stored in vials and syringes.

    PubMed

    Del Carmen Plancha-Mansanet, Maria; Caballero-Calabuig, Elisa; Félix-Fontestad, Jesús; Reyes-Ojeda, María Dolores; Sopena-Novales, Pablo; Abreu-Sánchez, Pedro; Del Carmen Cano-Terol, Maria; Sopena-Monforte, Ramón

    2008-12-01

    Our objective was to determine the stability of stabilized (99m)Tc-hexamethylpropylene amine oxime ((99m)Tc-d,l-HMPAO) dispensed by vial and syringe, with the storage time and labeling activity varied. (99m)Tc-d,l-HMPAO was labeled according to the manufacturer's instructions, but with modification of the (99m)TcO(4)Na activity. Two groups were prepared: 1,110 MBq (30 mCi) and 2,600-3,700 MBq (70.3-100 mCi). Five minutes after labeling, the radiochemical purity (RCP) of the vial content was determined. Afterward, the same activity was distributed into two 2-mL syringes and into the manufacturer's vial. In one of the syringes, the radiopharmaceutical stayed in contact with the needle for 4 h. At 2 and 4 h after labeling, the RCP of the vial and syringe content was checked and compared. The mean RCP of stabilized (99m)Tc-d,l-HMPAO labeled with 1,110 MBq (30 mCi) and stored in a vial decreased from 93.1% at 5 min to 92.1% at 2 h and to 91.1% at 4 h. With storage in a syringe, the RCP decreased from 89.8% at 2 h to 88.7% at 4 h. This diminution increased for labeling with higher activities (2,600-3,700 MBq [70.3-100 mCi]), ranging from 91.4% at 5 min, 89.0% at 2 h, and 85.3% at 4 h in a vial and from 85.9% at 2 h to 80.2% in a syringe. (99m)TcO(2) and secondary (99m)Tc-HMPAO were the main impurities at t = 0. (99m)TcO(4)(-) was an impurity that increased with time in both vials and syringes but significantly so in syringes. All these impurities were higher with labeling activities in the range of 2,600-3,700 MBq (70.3-100 mCi). Contact of the needle with (99m)Tc-d,l-HMPAO sharply decreased the RCP to 57.1% at 4 h. The RCP of stabilized (99m)Tc-d,l-HMPAO decreases significantly in both vials and syringes with high labeling activities. The product is less stable when stored in a syringe than in a vial. The fraction of dose in contact with the needle affects the RCP results.

  19. Formation of high-Tc YBa2Cu3O(7-delta) films on Y2BaCuO5 substrate

    NASA Astrophysics Data System (ADS)

    Wang, W. N.; Lu, H. B.; Lin, W. J.; Yao, P. C.; Hsu, H. E.

    1988-07-01

    High-Tc superconducting YBa2Cu3O(7-delta) films have been successfully prepared on green Y2BaCuO5 (2115) ceramic substrate. The films have been formed by RF sputtering and screen printing with post annealing at 925 C. Regarding superconducting features, the sharp resistivity drop with Tc onset around 95 K (midpoint 84 K) and 99 K (midpoint 89 K) has been observed for RF sputtered and printed films respectively. Both films show the excellent adhesion towards the 2115 substrate. Powder X-ray diffraction profiles indicate a majority of 1237 phase with preferred orientation for RF sputtered thin film.

  20. Comparison of different methods for radiochemical purity testing of [99mTc-EDDA-HYNIC-D-Phe1,Tyr3]-octreotide.

    PubMed

    von Guggenberg, Elisabeth; Penz, Barbara; Kemmler, Georg; Virgolini, Irene; Decristoforo, Clemens

    2006-02-01

    [99mTc-EDDA-HYNIC-D-Phe1,Tyr3]-octreotide (99mTc-EDDA-HYNIC-TOC) is an alternative radioligand for somatostatin receptor (SSTR) scintigraphy of neuroendocrine tumours. In order to allow a rapid and accurate determination of the quality in the clinical routine the aim of this study was to evaluate different methods of radiochemical purity (RCP) testing. Three different methods of RCP testing were compared: high-performance liquid chromatography (HPLC), thin layer chromatography (TLC) and minicolumn (Sep-Pak purification = SPE). HPLC was shown to be the most effective method for the quality control. The use of TLC and SPE is only recommended after sufficient practical labelling experience.

  1. 99mTc-EDDA/HYNIC-TOC in the management of medullary thyroid carcinoma.

    PubMed

    Parisella, Maria; D'Alessandria, Calogero; van de Bossche, Bieke; Chianelli, Marco; Ronga, Giuseppe; Papini, Enrico; Mikolajczak, Renata; Letizia, Claudio; De Toma, Giorgio; Veneziani, Augusto; Scopinaro, Francesco; Signore, Alberto

    2004-04-01

    An early diagnosis of distant metastases or local recurrences of medullary thyroid carcinoma (MTC) can be achieved by several conventional radiological modalities (e.g., ultrasonography, computed tomography [CT], and magnetic resonance imaging [MRI] as well as by radioisotopic procedures, such as positron emission tomography (PET), scintigraphy with different types of radiopharmaceuticals, and radiolabeled receptor-ligands in particular. The aim of this study was to evaluate the clinical utility of 99mTc-EDDA/HYNIC-TOC, a new octreotide derivative, to detect recurrences of disease or distant metastases in MTC. Images obtained of 5 patients with high levels of serum calcitonin were compared to findings obtained with other diagnostic procedures: 111In-octreotide, 99mTc-DMSA-V, 18F-flouro-D-deoxyglucose-PET, and CT/MRI. 99mTc-EDDA/HYNIC-TOC was positive in all patients and showed 15 areas of pathological uptake in the cervical and mediastinal regions. 111In-octreotide was positive in 3 of 3 patients and showed 4 areas, compared to 8 of 99mTc-EDDA/HYNIC-TOC. 99mTc-V-DMSA was positive in 3 of 4 patients but showed 6 pathological areas, compared to 13 of 99mTc-EDDA/HYNIC-TOC. 18F-FDG-PET was positive in 5 of 5 patients but showed only 11 areas, compared to 15 of 99mTc-EDDA/HYNIC-TOC. The CT scan was positive in only 2 patients. In conclusion, 99mTc-EDDA/HYNIC-TOC detected more sites of pathological uptake than other modalities, showed better imaging properties than 111In-octreotide, and might be the radiopharmaceutical of choice for providing a rationale for radioisotopic therapy.

  2. Effective detection of the tumors causing osteomalacia using [Tc-99m]-HYNIC-octreotide (99mTc-HYNIC-TOC) whole body scan.

    PubMed

    Jing, Hongli; Li, Fang; Zhuang, Hongming; Wang, Zhenghua; Tian, Jian; Xing, Xiaoping; Jin, Jin; Zhong, Dingrong; Zhang, Jingjing

    2013-11-01

    Tumor-induced osteomalacia (TIO) is an endocrine disorder caused by tumors producing excessive fibroblast growth factor-23 (FGF-23). The causative tumors are generally small, slow-growing benign mesenchymal tumors. The only cure of the disease depends on resection of the tumors, which are extremely difficult to localize due to their small sizes and rare locations. Since these tumors are known to express somatostatin receptors, this research was undertaken to evaluate efficacy of [Tc-99m]-HYNIC-octreotide (99mTc-HYNIC-TOC) whole body imaging in this clinical setting Images of 99mTc-HYNIC-TOC scans and clinical chart from 183 patients with hypophosphatemia and clinically suspected TIO were retrospectively reviewed. The scan findings were compared to the results of histopathological examinations and clinical follow-ups. Among 183 patients, 72 were confirmed to have TIO while 103 patients were found to have other causes of hypophosphatemia. The possibility of TIO could not be either diagnosed or excluded in the remaining 8 patients. For analytical purposes, these 8 patients who could neither be diagnosed nor excluded as having TIO were regarded as having the disease, bringing the total of TIO patients to 80. The 99mTc-HYNIC-TOC scan identified 69 tumors in 80 patients with TIO, which rendered a sensitivity of 86.3% (69/80). 99mTc-HYNIC-TOC scintigraphy excluded 102 patients without TIO with a specificity of 99.1% (102/103). The overall accuracy of 99mTc-HYNIC-TOC whole body scan in the localization of tumors responsible for osteomalacia is 93.4% (171/183). Whole body 99mTc-HYNIC-TOC imaging is effective in the localization of occult tumors causing TIO. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  3. Rhenium and technetium tricarbonyl, {M(CO)3} (+) (M = Tc, Re), binding to mammalian metallothioneins: new insights into chemical and radiopharmaceutical implications.

    PubMed

    Lecina, Joan; Palacios, Òscar; Atrian, Sílvia; Capdevila, Mercè; Suades, Joan

    2015-04-01

    This paper deals with the binding of the four mammalian metallothioneins (MTs) to the organometallic metal fragment {fac-M(CO)3}(+) (M = (99)Tc, Re), which is highly promising for the preparation of second-generation radiopharmaceuticals. The study of the transmetallation reaction between zinc and rhenium in Zn7-MT1 by means of UV-vis and CD spectroscopy demonstrated the incorporation of the {fac-Re(CO)3}(+) fragment to the MTs. This reaction should be performed at 70 °C to accelerate the reaction rate, a result that is consistent with the reported reactivity of the rhenium fragment. ESI-TOF MS demonstrated the formation of mixed-metal species as Zn6,{Re(CO)3}-MT, Zn6,{Re(CO)3}2-MT, and Zn5,{Re(CO)3}3-MT, as well as the different reactivity of the four MT isoforms. Hence, Zn-MT3 showed the highest reactivity, in agreement with its high Cu-thionein character, whereas Zn-MT2 exhibited the lowest reactivity, in line with its high Zn-thionein character. The reactivity of the Zn-loaded forms of MT1 and MT4 is intermediate between those of MT3 and MT2. The study of the binding of the {fac-(99)Tc(CO)3}(+) fragment to MTs showed a significant and very interesting different reactivity in relation to rhenium. The transmetallation reaction is much more effective with technetium than with rhenium and significant amounts of mixed Zn x ,{(99)Tc(CO)3} y -MT species were formed with the four MT isoforms whereas only MT3 rendered similar amounts of rhenium derivatives. The results obtained in this study support the possible use of technetium for labelling mammalian metallothioneins and also for possible radiopharmaceutical applications.

  4. Improving the Strength of the ZrC-SiC and TC4 Brazed Joint Through Fabricating Graded Double-Layered Composite Structure on TC4 Surface

    NASA Astrophysics Data System (ADS)

    Shi, J. M.; Zhang, L. X.; Chang, Q.; Sun, Z.; Feng, J. C.; Ma, N.

    2018-06-01

    In order to improve the ZrC-SiC ceramic and TC4 brazed joint property, graded double-layered SiC particles (SiCp)-reinforced TC4-based composite structure (named as GLS for convenience) was designed to relieve the residual stress in the joint. The GLS was successfully fabricated on TC4 substrate by double-layered laser deposition technology before the brazing process. The investigation of the GLS shows that the volume fraction of SiCp in the two composite layers was graded (20 and 39 vol pct, respectively). Ti5Si3 and TiC phases formed in the GLS due to the reaction of SiCp and TC4. The laser power-II (the laser power for the second deposition layer) affected the microstructure of the GLS significantly. Increasing the laser power-II would promote the reaction between the SiCp and TC4. But the high laser power-II made the layer I remelt completely and the two layers became homogeneous rather than graded structure. In the ZrC-SiC and TC4 brazed joint, the CTE (coefficient of thermal expansion) was graded from the TC4 to the ZrC-SiC due to the GLS, and the strength of the joint with the GLS (91 MPa) was higher than that without the GLS (43 MPa).

  5. Association between the -455T>C promoter polymorphism of the APOC3 gene and the metabolic syndrome in a multi-ethnic sample

    PubMed Central

    Pollex, Rebecca L; Ban, Matthew R; Young, T Kue; Bjerregaard, Peter; Anand, Sonia S; Yusuf, Salim; Zinman, Bernard; Harris, Stewart B; Hanley, Anthony JG; Connelly, Philip W; Huff, Murray W; Hegele, Robert A

    2007-01-01

    Background Common polymorphisms in the promoter of the APOC3 gene have been associated with hypertriglyceridemia and may impact on phenotypic expression of the metabolic syndrome (MetS). The rs7566605 marker, located near the INSIG2 gene, has been found to be associated with obesity, making it also a potential genetic determinant for MetS. The objective of this study is to examine the APOC3 -455T>C and the INSIG2 rs7566605 polymorphisms as potential genetic determinants for MetS in a multi-ethnic sample. Methods Subjects were genotyped for both the APOC3 -455T>C and INSIG2 rs7566605 polymorphisms, and classified for the presence or absence of MetS (NCEP ATP III and IDF definitions). The total study population included 2675 subjects (≥18 years of age) from six different geographical ancestries. Results For the overall study population, the prevalence of MetS was 22.6% (NCEP ATP III definition). Carriers of ≥1 copy of APOC3 -455C were more likely to have MetS (NCEP ATP III definition) than noncarriers (carrier odds ratio 1.73, 95% CI 1.40 to 2.14, adjusting for age and study group). The basis of the association was related not only to a higher proportion of -455C carriers meeting the triglyceride and high-density lipoprotein cholesterol criteria, but also the blood pressure criteria compared with wild-type homozygotes. Plasma apo C-III concentrations were not associated with APOC3 -455T>C genotype. The INSIG2 rs7566605 polymorphism was not associated with MetS or measures of obesity. Conclusion Meta-analysis of the sample of multiple geographic ancestries indicated that the functional -455T>C promoter polymorphism in APOC3 was associated with an approximately 2-fold increased risk of MetS, whereas the INSIG2 rs7566605 polymorphism was not associated with MetS. PMID:18096054

  6. Positron annihilation study of the high- Tc (Bi,Pb) 2Sr 2Ca 2Cu 3O x superconductor

    NASA Astrophysics Data System (ADS)

    Lim, H. J.; Byrne, J. G.

    1997-03-01

    Positron lifetime spectroscopy (PLS) and positron Doppler-broadening spectroscopy (PDBS) were applied to the high- Tc lead-doped Bi 2Sr 2Ca 2Cu 3O x (BPSCCO 2223) superconductor as a function of temperature. Neither positron lifetimes nor Doppler parameters ( S, W, and{S}/{W}) showed significant change through Tc. This may result from having the highest positron density in the open BiO 2 double layers and no significant positron density in the superconducting CuO 2 layers where positrons, if mainly present, are known to be sensitive to the transition in other high- Tc superconductors. Doppler parameters showed that the probability of positron annihilations with core electrons in the lattice slightly increased and that the probability of positron annihilations with conduction electrons slightly decreased as temperature decreased from ambient temperature to 20 K. The lifetime associated with positron annihilations in the perfect lattice of the sample ( τ1) was 209 ps and, due to the annihilations at internal surfaces or voids in the sample ( τ2) was about 540 ps, independent of temperature. Finally, the mean lifetime for BSCCO 2223 was about 307 ps.

  7. Cu-free 1,3-dipolar cycloaddition click reactions to form isoxazole linkers in chelating ligands for fac-[M(I)(CO)3]+ centers (M = Re, 99mTc).

    PubMed

    Bottorff, Shalina C; Kasten, Benjamin B; Stojakovic, Jelena; Moore, Adam L; MacGillivray, Leonard R; Benny, Paul D

    2014-02-17

    Isoxazole ring formation was examined as a potential Cu-free alternative click reaction to Cu(I)-catalyzed alkyne/azide cycloaddition. The isoxazole reaction was explored at macroscopic and radiotracer concentrations with the fac-[M(I)(CO)3](+) (M = Re, (99m)Tc) core for use as a noncoordinating linker strategy between covalently linked molecules. Two click assembly methods (click, then chelate and chelate, then click) were examined to determine the feasibility of isoxazole ring formation with either alkyne-functionalized tridentate chelates or their respective fac-[M(I)(CO)3](+) complexes with a model nitrile oxide generator. Macroscale experiments, alkyne-functionalized chelates, or Re complexes indicate facile formation of the isoxazole ring. (99m)Tc experiments demonstrate efficient radiolabeling with click, then chelate; however, the chelate, then click approach led to faster product formation, but lower yields compared to the Re analogues.

  8. In Vitro-Generated Tc17 Cells Present a Memory Phenotype and Serve As a Reservoir of Tc1 Cells In Vivo

    PubMed Central

    Flores-Santibáñez, Felipe; Cuadra, Bárbara; Fernández, Dominique; Rosemblatt, Mariana V.; Núñez, Sarah; Cruz, Pablo; Gálvez-Cancino, Felipe; Cárdenas, J. César; Lladser, Alvaro; Rosemblatt, Mario; Bono, María Rosa; Sauma, Daniela

    2018-01-01

    Memory CD8+ T cells are ideal candidates for cancer immunotherapy because they can mediate long-term protection against tumors. However, the therapeutic potential of different in vitro-generated CD8+ T cell effector subsets to persist and become memory cells has not been fully characterized. Type 1 CD8+ T (Tc1) cells produce interferon-γ and are endowed with high cytotoxic capacity, whereas IL-17-producing CD8+ T (Tc17) cells are less cytotoxic but display enhanced self-renewal capacity. We sought to evaluate the functional properties of in vitro-generated Tc17 cells and elucidate their potential to become long lasting memory cells. Our results show that in vitro-generated Tc17 cells display a greater in vivo persistence and expansion in response to secondary antigen stimulation compared to Tc1 cells. When transferred into recipient mice, Tc17 cells persist in secondary lymphoid organs, present a recirculation behavior consistent with central memory T cells, and can shift to a Tc1 phenotype. Accordingly, Tc17 cells are endowed with a higher mitochondrial spare respiratory capacity than Tc1 cells and express higher levels of memory-related molecules than Tc1 cells. Together, these results demonstrate that in vitro-generated Tc17 cells acquire a central memory program and provide a lasting reservoir of Tc1 cells in vivo, thus supporting the use of Tc17 lymphocytes in the design of novel and more effective therapies. PMID:29472932

  9. Photochemical behavior of the quadruply metal-metal bonded [Tc 2Cl 8] 2– anion in acetonitrile

    DOE PAGES

    Burton-Pye, Benjamin P.; Poineau, Frederic; Bertoia, Julie; ...

    2016-09-23

    Here, the photochemical behavior of [Tc 2Cl 8] 2– was investigated in acetonitrile. The speciation of Tc before and after irradiation at 254 nm was performed by UV-visible spectroscopy and electrospray ionization mass spectrometry (ESI-MS). Upon irradiation at 254 nm, [Tc 2Cl 8] 2– was unstable, the scission of the TcTc unit occurred and the complex [TcCl 4(CH 3CN) 2] was identified. The disappearance rate of [M 2Cl 8] 2– (M = Tc, Re) under irradiation has been measured and was ~7.5 time faster for Tc than for Re.

  10. Specificity and sensitivity of ⁹⁹mTc-EDDA/HYNIC-Tyr³-octreotide (⁹⁹mTc-TOC) for imaging neuroendocrine tumors.

    PubMed

    Sepúlveda-Méndez, Jesús; de Murphy, Consuelo Arteaga; Pedraza-López, Martha; Murphy-Stack, Eduardo; Rojas-Bautista, Juan Carlos; González-Treviño, Ofelia

    2012-01-01

    Gastroenteropancreatic neuroendocrine tumors (NETs) are cancers originating from neuroendocrine organs such as the pancreas, pituitary, thyroid, and adrenal glands and tumors arising from the diffuse neuroendocrine cells that are widely distributed throughout the body. NETs express somatostatin (SS) and contain a high density of SS receptors; therefore, they can be specifically targeted with SS-based radiopharmaceuticals. The aim of this research was to determine the validity in terms of specificity, sensitivity, and the agreement beyond chance with the biopsy (gold standard) of the ⁹⁹mTc-EDDA-HYNIC-Tyr³octreotide (⁹⁹mTc-TOC) to image and localize NETs and their metastases. Freeze-dried kits containing 0.0125 mg HYNIC-octreotide and co-ligands were easily labeled and quality controlled within the hospital radiopharmacy. Fifty-six consecutive Mexican patients with a previous presumptive diagnosis of NETs underwent several clinical and laboratory studies and were referred to the Nuclear Medicine Department for a routine scan with ⁹⁹mTc-TOC. The patients were injected with 500-600 MBq ⁹⁹mTc-TOC, and whole-body images were obtained 2 h later with a SPECT or a SPECT/CT camera. Two nuclear medicine physicians observed the images and classified them as 17 negative and 39 positive. After correlating the image of each patient with our 'gold standard' (biopsy, clinical history, morphological images, and tumor marker assays), the ⁹⁹mTc-TOC images were classified by the same two physicians as 12 true negatives, five false negatives, 38 true positives and one false positive. The validity of ⁹⁹mTc-TOC in terms of relative frequencies with corresponding 95% confidence intervals were as follows: 92.3% (64-100%) specificity; 88.4% (78-97%) sensitivity; and the agreement beyond chance was 73% (60-84%). The positive predictive value was 97.4% (87-100%); the negative predicted value was 70.6% (48-93%); the accuracy was 89.3% (89-97%); and the prevalence was 76

  11. ECT imaging with Tc(V)-99m dimercaptosuccinic acid useful to detect lung metastases of osteosarcoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ohta, H.; Ishii, M.; Yoshizumi, M.

    1985-01-01

    ECT imaging, using Tc(V)-99m dimercaptosuccinic acid (Tc(V)-DMS) was performed in two patients with lung metastasis of osteosarcoma, and the results were compared with those of CT scan. Clear accumulation of Tc(V)-DMS was recognized in all cases in the same area that CT scans demonstrated. Tc(V)-DMS was labeled under optimal pH 8, had very low SnCl/sub 2/ concentrations, an equilibrium between a stable form and a dissociated form of anion TcO/sub 4/(3-) structurally similar to PO/sub 4/(3-), and was postulated for tumor uptake. Considering this proposed mechanism for Tc(V)-DMS uptake by tumor cells, ECT imaging using this tracer could be ofmore » use in the early detection of lung metastasis of osteosarcoma.« less

  12. Differential Activation of CD8+ Tumor-Specific Tc1 and Tc2 Cells by an IL-10-Producing Murine Plasmacytoma

    PubMed Central

    Pauels, Hans-Gerd; Becker, Christian; Kölsch, Eckehart

    1998-01-01

    The involvement of counteractive CD8+ T-cell subsets during tumor-specific immune responses was analyzed in a syngeneic murine plasmacytoma model. CD8+ Tc cells against the immunogenic IL-10-producing BALB/c plasmacytoma ADJ-PC-5 can be easily induced by immunization of BALB/c mice with X-irradiated ADJ-PC-5 tumor cells in vivo and in vitro. However, the failure of recipient mice to mount a protective Tc response against the tumor during early stages of a real or simulated tumor growth is not due to immunological ignorance, but depends on the induction of tumor-specific tolerance, involving a population of tumorinduced CD8+ T cells that are able to inhibit the generation of tumor-specific Tc cells in a primary ADJ-PC-5-specific MLTC, using IFN-γ as a suppressive factor. Whereas most longterm cultivated CD8+ ADJ-PC-5-specific Tc lines produce type-1 cytokines on stimulation, at least two of them, which were derived from a primary MLTC, display a type-2 cytokine spectrum. Furthermore, the primary in vitro Tc response against ADJ-PC-5 cells shows characteristics of a Tc2 response. The Tc response is strictly depending on tumor-derived IL-10. CD8+ Tc cells that are induced in a primary MLTC do not produce IFN-γ, and the tumor-specific Tc response is enhanced by IL-4 but suppressed by IFN-γ or IL-12. In contrast, ADJ-PC- 5-specific CD8+ Tc cells from immunized mice are IFN-γ producing Tc1 cells. Since the primary in vitro Tc response against the tumor is suppressed even by the smallest numbers of irradiated ADJ-PC-5-specific Tc1 cells via IFN-γ these Tc1 cells behave similar to the suppressive CD8+ T cells that are induced during early stages of ADJ-PC-5 tumorigenesis. PMID:9814607

  13. [Evaluation of left ventricular diastolic function using gated SPECT with 99mTc-MIBI].

    PubMed

    Toba, M; Kumita, S I; Mizumura, S; Cho, K; Kijima, T; Takahama, K; Kumazaki, T

    1996-04-01

    Development of 3 head SPECT system and 99mTc-labeled radiopharmaceuticals enable us to evaluate left ventricular systolic function on the basis of once gated SPECT routine. This study was focused on assessment of left ventricular diastolic function using 99mTc-MIBI gated SPECT data. Twenty nine patients with ischemic heart diseases underwent 99mTc-MIBI gated SPECT and 99mTc-HSAD ventriculographic assessment of left ventricular diastolic function within 1 month. Region of interests (ROI), simultaneously calculating counts per pixel within ROI, were placed over whole myocardium of 16 serial phasic images reconstructed from gated SPECT data, following selection of the central slice within short axial images. Then, 29 patients were classified into 3 patterns of phase count curve (normal, mixed, and delayed relaxation = diastolic dysfunction). Moreover, 1/3 Count Decreasing Fraction (1/3 CDF) was calculated on the same concept as 1/3 FF. The curve pattern showed significant differences between normal and abnormal group divided on the basis of established indices such as 1/3 FF and PFR, and 1/3 CDF has correlations with 1/3 FF (r = 0.61) and PFR (r = 0.58). We concluded that the new parameters drawn from 99mTc-MIBI gated SPECT data might be feasible for evaluation of diastolic function.

  14. Operational field evaluation of the PAC-MAG man-portable magnetometer array

    NASA Astrophysics Data System (ADS)

    Keranen, Joe; Topolosky, Zeke; Schultz, Gregory; Miller, Jonathan

    2013-06-01

    Detection and discrimination of unexploded ordnance (UXO) in areas of prior conflict is of high importance to the international community and the United States government. For humanitarian applications, sensors and processing methods need to be robust, reliable, and easy to train and implement using indigenous UXO removal personnel. This paper describes system characterization, system testing, and a continental United States (CONUS) Operational Field Evaluations (OFE) of the PAC-MAG man-portable UXO detection system. System testing occurred at a government test facility in June, 2010 and December, 2011 and the OFE occurred at the same location in June, 2012. NVESD and White River Technologies personnel were present for all testing and evaluation. The PAC-MAG system is a manportable magnetometer array for the detection and characterization of ferrous UXO. System hardware includes four Cesium vapor magnetometers for detection, a Real-time Kinematic Global Position System (RTK-GPS) for sensor positioning, an electronics module for merging array data and WiFi communications and a tablet computer for transmitting and logging data. An odometer, or "hipchain" encoder, provides position information in GPS-denied areas. System software elements include data logging software and post-processing software for detection and characterization of ferrous anomalies. The output of the post-processing software is a dig list containing locations of potential UXO(s), formatted for import into the system GPS equipment for reacquisition of anomalies. Results from system characterization and the OFE will be described.

  15. Tc-labeling of Peptidomimetic Antagonist to Selectively Target alpha(v)beta(3) Receptor-Positive Tumor: Comparison of PDA and EDDA as co-Ligands.

    PubMed

    Shin, In Soo; Maeng, Jin Soo; Jang, Beom-Su; You, Eric; Cheng, Kenneth; Li, King C P; Wood, Bradford; Carrasquillo, Jorge A; Danthi, S Narasimhan; Paik, Chang H

    2010-01-01

    OBJECTIVES: The aim of this research was to synthesize radiolabeled peptidomimetic integrin alpha(v)beta(3) antagonist with (99m)Tc for rapid targeting of integrin alpha(v)beta(3) receptors in tumor to produce a high tumor to background ratio. METHODS: The amino terminus of 4-[2-(3,4,5,6-tetra-hydropyrimidin-2-ylamino)-ethyloxy]benzoyl-2-(S)-[N-(3-amino-neopenta-1-carbamyl)]-aminoethylsulfonyl-amino-beta-alanine hydrochloride (IAC) was conjugated with N-hydroxysuccinimide ester of HYNIC and labeled with (99m)Tc using tricine with either 1,5-pyridinedicarboxylic acid (PDA) or ethylenediamine-N,N'-diacetic acid (EDDA) as the co-ligand. The products, (99m)Tc EDDA(2)/HYNIC-IAC (P1) and (99m)Tc PDA (tricin)/HYNIC-IAC (P2) were subjected to in vitro serum stability, receptor-binding, biodistribution and imaging studies. RESULTS: P1 and P2 were synthesized with an overall yield of >80%. P1 was slightly more stable than P2 when incubated in serum at 37 degrees C for 18 hrs (84 vs 77% intact). The In vitro receptor-binding of P1 was higher than that of P2 (78.02 +/- 13.48 vs 51.05 +/- 14.05%) when incubated with alpha(v)beta(3) at a molar excess (0.8 muM). This receptor binding was completely blocked by a molar excess of an unlabeled peptidomimetic antagonist. Their differences shown in serum stability and the receptor-binding appeared to be related to their biological behaviors in tumor uptake and retention; the 1 h tumor uptakes of P1 and P2 were 3.17+/-0.52 and 2.13+/-0.17 % ID/g, respectively. P1 was retained in the tumor longer than P2. P1 was excreted primarily through the renal system whereas P2 complex was excreted equally via both renal and hepatobiliary systems. Thus, P1 was retained in the whole-body with 27.25 +/- 3.67% ID at 4 h whereas 54.04 +/- 3.57% ID of P2 remained in the whole-body at 4 h. This higher whole-body retention of P2 appeared to be resulted from a higher amount of radioactivity retained in liver and intestine. These findings were supported by

  16. Method for the production of .sup.99m Tc compositions from .sup.99 Mo-containing materials

    DOEpatents

    Bennett, Ralph G.; Christian, Jerry D.; Grover, S. Blaine; Petti, David A.; Terry, William K.; Yoon, Woo Y.

    1998-01-01

    An improved method for producing .sup.99m Tc compositions from .sup.99 Mo compounds. .sup.100 Mo metal or .sup.100 MoO.sub.3 is irradiated with photons in a particle (electron) accelerator to ultimately produce .sup.99 MoO.sub.3. This composition is then heated in a reaction chamber to form a pool of molten .sup.99 MoO.sub.3 with an optimum depth of 0.5-5 mm. A gaseous mixture thereafter evolves from the molten .sup.99 MoO.sub.3 which contains vaporized .sup.99 MoO.sub.3, vaporized .sup.99m TcO.sub.3, and vaporized .sup.99m TcO.sub.2. This mixture is then combined with an oxidizing gas (O.sub.2(g)) to generate a gaseous stream containing vaporized .sup.99m Tc.sub.2 O.sub.7 and vaporized .sup.99 MoO.sub.3. Next, the gaseous stream is cooled in a primary condensation stage in the reaction chamber to remove vaporized .sup.99 MoO.sub.3. Cooling is undertaken at a specially-controlled rate to achieve maximum separation efficiency. The gaseous stream is then cooled in a sequential secondary condensation stage to convert vaporized .sup.99m Tc.sub.2 O.sub.7 into a condensed .sup.99m Tc-containing reaction product which is collected.

  17. Method for the production of {sup 99m}Tc compositions from {sup 99}Mo-containing materials

    DOEpatents

    Bennett, R.G.; Christian, J.D.; Grover, S.B.; Petti, D.A.; Terry, W.K.; Yoon, W.Y.

    1998-09-01

    An improved method is described for producing {sup 99m}Tc compositions from {sup 99}Mo compounds. {sup 100}Mo metal or {sup 100}MoO{sub 3} is irradiated with photons in a particle (electron) accelerator to ultimately produce {sup 99}MoO{sub 3}. This composition is then heated in a reaction chamber to form a pool of molten {sup 99}MoO{sub 3} with an optimum depth of 0.5--5 mm. A gaseous mixture thereafter evolves from the molten {sup 99}MoO{sub 3} which contains vaporized {sup 99}MoO{sub 3}, vaporized {sup 99m}TcO{sub 3}, and vaporized {sup 99m}TcO{sub 2}. This mixture is then combined with an oxidizing gas (O{sub 2(g)}) to generate a gaseous stream containing vaporized {sup 99m}Tc{sub 2}O{sub 7} and vaporized {sup 99}MoO{sub 3}. Next, the gaseous stream is cooled in a primary condensation stage in the reaction chamber to remove vaporized {sup 99}MoO{sub 3}. Cooling is undertaken at a specially-controlled rate to achieve maximum separation efficiency. The gaseous stream is then cooled in a sequential secondary condensation stage to convert vaporized {sup 99m}Tc{sub 2}O{sub 7} into a condensed {sup 99m}Tc-containing reaction product which is collected. 1 fig.

  18. Growth And Patterning Of High-Tc Superconducting Films

    NASA Technical Reports Server (NTRS)

    Warner, J. D.; Bhasin, K. B.; Varaljay, N. C.; Bohman, D. Y.; Chorey, C. M.

    1992-01-01

    Superconducting films of YBa(2)Cu(3)O(7-delta), having high superconducting-transition temperatures (Tc's), deposited on LaAlO3 substrates and etched into patterns representative of passive microwave devices, with no deterioration of superconducting properties.

  19. A freeze-dried kit formulation for the preparation of Lys(27)(99mTc-EDDA/HYNIC)-Exendin(9-39)/99mTc-EDDA/HYNIC-Tyr3-Octreotide to detect benign and malignant insulinomas.

    PubMed

    Medina-García, Veronica; Ocampo-García, Blanca E; Ferro-Flores, Guillermina; Santos-Cuevas, Clara L; Aranda-Lara, Liliana; García-Becerra, Rocio; Ordaz-Rosado, David; Melendez-Alafort, Laura

    2015-12-01

    About 90% of insulinomas are benign and 5%-15% are malignant. Benign insulinomas express the glucagon-like peptide-1 receptor (GLP-1R) and low levels of somatostatin receptors (SSTR), while malignant insulinomas over-express SSTR or GLP-1R in low levels. A kit for the preparation of Lys(27)((99m)Tc-EDDA/HYNIC)-Exendin(9-39)/(99m)Tc-EDDA/HYNIC-Tyr(3)Octreotide was formulated to detect 100% of insulinomas. The formulation showed radiochemical purity of 97±1%, high stability in human serum, and GLP-1R and SSTR affinity. The biodistribution and imaging studies demonstrated properties suitable for its use as a target-specific agent for the simultaneous molecular imaging of GRP-1R- and/or SSTR-positive tumors. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Systematic XAS study on the reduction and uptake of Tc by magnetite and mackinawite.

    PubMed

    Yalçıntaş, Ezgi; Scheinost, Andreas C; Gaona, Xavier; Altmaier, Marcus

    2016-11-28

    The mechanisms for the reduction and uptake of Tc by magnetite (Fe 3 O 4 ) and mackinawite (FeS) are investigated using X-ray absorption spectroscopy (XANES and EXAFS), in combination with thermodynamic calculations of the Tc/Fe systems and accurate characterization of the solution properties (pH m , pe, [Tc]). Batch sorption experiments were performed under strictly anoxic conditions using freshly prepared magnetite and mackinawite in 0.1 M NaCl solutions with varying initial Tc(vii) concentrations (2 × 10 -5 and 2 × 10 -4 M) and Tc loadings (400-900 ppm). XANES confirms the complete reduction of Tc(vii) to Tc(iv) in all investigated systems, as predicted from experimental (pH m + pe) measurements and thermodynamic calculations. Two Tc endmember species are identified by EXAFS in the magnetite system, Tc substituting for Fe in the magnetite structure and Tc-Tc dimers sorbed to the magnetite {111} faces through a triple bond. The sorption endmember is favoured at higher [Tc], whereas incorporation prevails at low [Tc] and less alkaline pH conditions. The key role of pH in the uptake mechanism is interpreted in terms of magnetite solubility, with higher [Fe] and greater recrystallization rates occurring at lower pH values. A TcS x -like phase is predominant in all investigated mackinawite systems, although the contribution of up to 20% of TcO 2 ·xH 2 O(s) (likely as surface precipitate) is observed for the highest investigated loadings (900 ppm). These results provide key inputs for an accurate mechanistic interpretation of the Tc uptake by magnetite and mackinawite, so far controversially discussed in the literature, and represent a highly relevant contribution to the investigation of Tc retention processes in the context of nuclear waste disposal.

  1. Re-Search for Extinct 99Tc and 98Tc in the Early Solar System

    NASA Astrophysics Data System (ADS)

    Yin, Q.; Jagoutz, E.; Wanke, H.

    1992-07-01

    .89+- 0.24epsilon) of the ^99Ru/^101Ru ratio from the terrestrial mean is observed, a first indication that ^99Tc was alive in the early solar system. With the production ratio of ^99Tc/^99Ru=0.75 (Kappeler et al., 1989), a 2.9+-0.2 m.y. time interval (delta) between the nucleosynthetic process and formation of Maralinga is calculated, assuming there is no significant Tc/Ru fractionation since their production. This time interval is consistent with delta>=1.8 m.y. set by ^41Ca (tau(sub)1/2=1.03x10^5 yr) result (Hutcheon et al., 1984) and delta<=~3 m.y. inferred from ^26Al (tau(sub)1/2=7.16x10^5 yr) result (Lee et al., 1977), and gives the most stringent control on delta for the related nucleosynthetic process. The ^99Ru/^101Ru ratio in Gibeon is within error of the laboratory standard value. Since the nucleosynthetic origins of ^107Pd and ^99Tc are similar, the absence of ^99Ru anomaly (^99Ru*) and the presence of ^107Ag* in Gibeon (Chen and Wasserburg, 1990) indicate that core-mantle differentiation in the parent body of Gibeon happened between 2 and 10 m.y. after the nucleosynthetic sources produced these two parent nuclides. In this time span ^26Al was still alive and thus supports the model of ^26Al being a heat source for early planetary differentiation. Chen, J. H. and Wasserburg, G. J. , Geochim. Cosmochim. Acta. (1990) 54, 1729-1743. Creaser, R. A., Papanastassiou, D. A. and Wasserburg, G. J. (1991) Geochim. Cosmochim. Acta. 55, 397-401. Herr, W., Merz, E., Eberhardt, P., Geiss, J., Lang, C. and Signer, P. (1958) Geochim. Cosmochim. Acta. 14, 158. Hutcheon, I. D., Armstrong, J. T., and Wasserburg, G. J. (1984) LPSC XV, 387-388 (abstract). Kappeler, F., Beer, H., and Wisshak, K. (1989) Rep. Prog. Phys. 52. 945-1013. Lee, T., Papanastassiou, D. A. and Wasserburg, G. J. (1977) Astrophys. J. (Letters) 211, L107-L110. Smith, V. V. and Lambert, D. L. (1988)t. Astrophys. J., 333, 219- 226.

  2. Radiopharmaceutical considerations for using Tc-99m MAA in lung transplant patients.

    PubMed

    Ponto, James A

    2010-01-01

    To elucidate radiopharmaceutical considerations for using technetium Tc-99m albumin aggregated (Tc-99m MAA) in lung transplant patients and to establish an appropriate routine dose and preparation procedure. Tertiary care academic hospital during May 2007 to May 2009. Nuclear pharmacist working in nuclear medicine department. Radiopharmaceutical considerations deemed important for the use of Tc-99m MAA in lung transplant patients included radioactivity dose, particulate dose, rate of the radiolabeling reaction (preparation time), and final radiochemical purity. Evaluation of our initial 12-month experience, published literature, and professional practice guidelines provided the basis for establishing an appropriate dose and preparation procedure of Tc-99m MAA for use in lung transplant patients. Radiochemical purity at typical incubation times and image quality in subsequent lung transplant patients imaged during the next 12 months. Based on considerations of radioactivity dose, particulate dose, rate of the radiolabeling reaction (preparation time), and final radiochemical purity, a routine dose consisting of 3 mCi (111 MBq) and 100,000 particles of Tc-99m MAA for planar perfusion lung imaging of adult lung transplant patients was established as reasonable and appropriate. MAA kits were prepared with a more reasonable amount of Tc-99m and yielded high radiochemical purity values in typical incubation times. Images have continued to be of high diagnostic quality. Tc-99m MAA used for lung transplant imaging can be readily prepared with high radiochemical purity to provide a dose of 3 mCi (111 GBq)/100,000 particles, which provides images of high diagnostic quality.

  3. Synthesis of trevorite to capture Tc

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsui, Colin

    2011-09-02

    Spinel containing technetium can be used to prevent Tc volatilization during vitrification of radioactive waste. Spinel dissolves in glass at elevated temperatures. This study focuses on the synthesis of spinel and the retention of rhenium, a nonradioactive surrogate for Tc in the crystals. To produce trevorite, a nickel-iron spinel (NiFe2O4), Fe and Ni nitrates were mixed with alkali nitrates along with Al(OH)3 and heated to 500 to 800°C. The trevorite content in samples (up to 40 mass%) was measured with x-ray diffraction. Viable samples were rerun with KReO4. Scanning electron microscopy-energy dispersive spectroscopy detected that Re became partly immobilized inmore » spinel-forming crystals.« less

  4. Mass estimate and close approaches of near-Earth asteroid 2015 TC25

    NASA Astrophysics Data System (ADS)

    Farnocchia, Davide; Tholen, David J.; Micheli, Marco; Ryan, William; Rivera-Valentin, Edgard G.; Taylor, Patrick A.; Giorgini, Jon D.

    2017-10-01

    Near-Earth asteroid 2015 TC25 was discovered by the Catalina Sky Survey in October 2015, just two days before an Earth flyby at 0.3 lunar distances. By using ground-based optical, near-infrared, and radar assets during the flyby, Reddy et al. (2016) successfully characterized 2015 TC25. They suggested that the object has a high albedo and a diameter of 2 m, which makes 2015 TC25 one of the smallest asteroids ever detected. Moreover, the orbital information available at the end of the 2015 apparition indicated that 2015 TC25 had a probability of an Earth impact of more than 1 in 10000 from 2070 to 2115. To rule out possible impacts we recovered 2015 TC25 at the end of March 2017 and continued tracking the object through the end of April, when it became too faint to be observable. The recent 2017 astrometry clearly shows the action of solar radiation pressure on the orbit of 2015 TC25 with a 7.6-sigma detection. This solar radiation pressure estimate allows us to put constraints on the density and mass of 2015 TC25 and further suggests that the object is only a couple of meters in size. In particular, the area-to-mass ratio is between 0.6 m^2/t and 0.7 m^2/t and, for a diameter of 2 m, the density is about 1.1 g/cm^3. By accounting for the contribution of non-gravitational perturbations, we analyze the future trajectory of 2015 TC25. Based on the extended data arc, ephemeris predictions are now deterministic until the Earth close approach in 2089 and a Monte Carlo search rules out impacts for the next 100 years.

  5. Adolescent Services & the TC. Chapter 6.

    ERIC Educational Resources Information Center

    Acampora, Alfonso P., Ed.; Nebelkopf, Ethan, Ed.

    This document contains seven papers from the ninth World Conference of Therapeutic Communities (TCs) that deal with adolescent clients and TCs. Papers include: (1) Preliminary Consideration on "Adolescence and the TC" (David Deitch); (2) "Daytop's Full Service Adolescent Treatment Program" (Charles Devlin and Lois Morris); (3)…

  6. Targeted functional imaging of estrogen receptors with 99mTc-GAP-EDL.

    PubMed

    Takahashi, Nobukazu; Yang, David J; Kohanim, Saady; Oh, Chang-Sok; Yu, Dong-Fang; Azhdarinia, Ali; Kurihara, Hiroaki; Zhang, Xiaochun; Chang, Joe Y; Kim, E Edmund

    2007-03-01

    To evaluate the feasibility of using (99m)Tc-glutamate peptide-estradiol in functional imaging of estrogen receptor-positive [ER(+)] diseases. 3-Aminoethyl estradiol (EDL) was conjugated to glutamate peptide (GAP) to yield GAP-EDL. Cellular uptake studies of (99m)Tc-GAP-EDL were conducted in ER(+) cell lines (MCF-7, 13762 and T47D). To demonstrate whether GAP-EDL increases MAP kinase activation, Western blot analysis of GAP-EDL was performed in 13762 cells. Biodistribution was conducted in nine rats with 13762 breast tumors at 0.5-4 h. Each rat was administered (99m)Tc-GAP-EDL. Two animal models (rats and rabbits) were created to ascertain whether tumor uptake of (99m)Tc-GAP-EDL was via an ER-mediated process. In the tumor model, breast tumor-bearing rats were pretreated with diethylstilbestrol (DES) 1 h prior to receiving (99m)Tc-GAP-EDL. In the endometriosis model, part of the rabbit uterine tissue was dissected and grafted to the peritoneal wall. The rabbit was administered with (99m)Tc-GAP-EDL. There was a 10-40% reduction in uptake of (99m)Tc-GAP-EDL in cells treated with DES or tamoxifen compared with untreated cells. Western blot analysis showed an ERK1/2 phosphorylation process with GAP-EDL. Biodistribution studies showed that tumor uptake and tumor-to-muscle count density ratio in (99m)Tc-GAP-EDL groups were significantly higher than those in (99m)Tc-GAP groups at 4 h. Among (99m)Tc-GAP-EDL groups, region of interest analysis of images showed that tumor-to muscle ratios were decreased in blocking groups. In the endometriosis model, the grafted uterine tissue could be visualized by (99m)Tc-GAP-EDL. Cellular or tumor uptake of (99m)Tc-GAP-EDL occurs via an ER-mediated process. (99m)Tc-GAP-EDL is a useful agent for imaging functional ER(+) disease.

  7. The differentiation and plasticity of Tc17 cells are regulated by CTLA-4-mediated effects on STATs.

    PubMed

    Arra, Aditya; Lingel, Holger; Kuropka, Benno; Pick, Jonas; Schnoeder, Tina; Fischer, Thomas; Freund, Christian; Pierau, Mandy; Brunner-Weinzierl, Monika C

    2017-01-01

    As the blockade of inhibitory surface-molecules such as CTLA-4 on T cells has led to recent advances in antitumor immune therapy, there is great interest in identifying novel mechanisms of action of CD8 + T cells to evoke effective cytotoxic antitumor responses. Using in vitro and in vivo models, we investigated the molecular pathways underlying the CTLA-4-mediated differentiation of IL-17-producing CD8 + T cells (Tc17 cells) that strongly impairs cytotoxicity. Our studies demonstrate that Tc17 cells lacking CTLA-4 signaling have limited production of STAT3-target gene products such as IL-17, IL-21, IL-23R and RORγt. Upon re-stimulation with IL-12, these cells display fast downregulation of Tc17 hallmarks and acquire Tc1 characteristics such as IFNγ and TNF-α co-expression, which is known to correlate with tumor control. Indeed, upon adoptive transfer, these cells were highly efficient in the antigen-specific rejection of established OVA-expressing B16 melanoma in vivo . Mechanistically, in primary and re-stimulated Tc17 cells, STAT3 binding to the IL-17 promoter was strongly augmented by CTLA-4, associated with less binding of STAT5 and reduced relative activation of STAT1 which is known to block STAT3 activity. Inhibiting CTLA-4-induced STAT3 activity reverses enhancement of signature Tc17 gene products, rendering Tc17 cells susceptible to conversion to Tc1-like cells with enhanced cytotoxic potential. Thus, CTLA-4 critically shapes the characteristics of Tc17 cells by regulating relative STAT3 activation, which provides new perspectives to enhance cytotoxicity of antitumor responses.

  8. Herbal remedy magnolol suppresses IL-6-induced STAT3 activation and gene expression in endothelial cells

    PubMed Central

    Chen, Shih-Chung; Chang, Ying-Ling; Wang, Danny Ling; Cheng, Jing-Jy

    2006-01-01

    Magnolol (Mag), an active constituent isolated from the Chinese herb Hou p'u (Magnolia officinalis) has long been used to suppress inflammatory processes. Chronic inflammation is well known to be involved in vascular injuries such as atherosclerosis in which interleukin (IL)-6 may participate. Signal transducer and activator of transcription protein 3 (STAT3), a transcription factor involved in inflammation and the cell cycle, is activated by IL-6. In this study, we evaluated whether Mag can serve as an anti-inflammatory agent during endothelial injuries. The effects of Mag on IL-6-induced STAT3 activation and downstream target gene induction in endothelial cells (ECs) were examined. Pretreatment of ECs with Mag dose dependently inhibited IL-6-induced Tyr705 and Ser727 phosphorylation in STAT3 without affecting the phosphorylation of JAK1, JAK2, and ERK1/2. Mag pretreatment of these ECs dose dependently suppressed IL-6-induced promoter activity of intracellular cell adhesion molecule (ICAM)-1 that contains functional IL-6 response elements (IREs). An electrophoretic mobility shift assay (EMSA) revealed that Mag treatment significantly reduced STAT3 binding to the IRE region. Consistently, Mag treatment markedly inhibited ICAM-1 expression on the endothelial surface. As a result, reduced monocyte adhesion to IL-6-activated ECs was observed. Furthermore, Mag suppressed IL-6-induced promoter activity of cyclin D1 and monocyte chemotactic protein (MCP)-1 for which STAT3 activation plays a role. In conclusion, our results indicate that Mag inhibits IL-6-induced STAT3 activation and subsequently results in the suppression of downstream target gene expression in ECs. These results provide a therapeutic basis for the development of Mag as an anti-inflammatory agent for vascular disorders including atherosclerosis. PMID:16520748

  9. Comparative analysis of 99mTc-depreotide and 99mTc-EDDA/HYNIC-TOC thorax scintigrams acquired for the purpose of differential diagnosis of solitary pulmonary nodules.

    PubMed

    Płachcińska, Anna; Mikołajczak, Renata; Kozak, Józef; Rzeszutek, Katarzyna; Kuśmierek, Jacek

    2006-01-01

    Aiming at comparison of diagnostic efficacy of 2 radiopharmaceuticals: 99mTc-depreotide (Neospect, Amersham) and 99mTc-EDDA/HYNIC-Tyr3-octreotide (Tektrotyd, Polatom), in differentiation between malignant and benign etiology of solitary pulmonary nodules (SPNs), radionuclide studies with 2 radiotracers were performed in 18 patients. For both radiopharmaceuticals the same acquisition and processing protocols were applied. Studies were acquired with SPECT technique, after administration of 740 MBq of activity. Scintigrams were assessed visually, as: positive (+), equivocal (+/-) and negative (-). Additionally, uptake intensity of both radiotracers in nodules was assessed semiquantitatively, using a tumour-to-background ratio. Verification of scintigraphic results was based in 14 cases upon a pathological examination of tumour samples (histopathology) and in the remaining 4 - on clinical observation and bacteriological studies. Normal scintigrams obtained with both radiopharmaceuticals differed significantly. 99mTc-depreotide was markedly accumulated in spine, sternum, ribs and lungs (mean lung/heart ratio = 2.2). This accumulation was not observed on 99mTc- -EDDA/HYNIC-TOC scintigrams (mean lung/heart ratio = 0.7). In 6 patients a malignant etiology--lung cancer--was revealed (5--adenocarcinoma, 1--squamous cell) and the other 12 cases turned out to be benign (4 hamartomas, 3 tuberculomas, a tuberculous infiltrate, an alien body with inflammatory reaction, a hyperplasia of lymphatic tissue and 2 cases of unknown etiology, from which one had a stable size and the other resolved during a 6 month observation period). In all 6 cases of lung cancer positive results were obtained with both tracers. Moreover, in 2 patients metastases in mediastinum could be observed on scintigrams obtained with both radiopharmaceuticals. From among 12 cases of benign etiology 6 99mTc-depreotide scintigrams were true negative, 1--equivocal and 5--false positive, whereas 6 99mTc

  10. .sup.100Mo compounds as accelerator targets for production of .sup.99mTc

    DOEpatents

    Richards, Vernal; Lapi, Suzanne

    2016-09-20

    Methods of synthesizing .sup.100Mo.sub.2C and .sup.99mTcO.sub.4.sup.- are disclosed. Methods of .sup.100Mo.sub.2C generation involve thermally carburizing .sup.100MoO.sub.3. Methods of .sup.99mTcO.sub.4 generation involve proton bombardment of .sup.100Mo.sub.2C in a cyclotron. Yields of .sup.99mTcO.sub.4 can be increased by sintering .sup.100Mo.sub.2C prior to bombardment. The methods also include recycling of .sup.100Mo.sub.2C to form .sup.100MoO.sub.3. SPECT images obtained using .sup.99mTcO.sub.4 generated by the disclosed methods are also presented.

  11. Hydrometeor Trajectories and Distributions in a Simulation of TC Rapid Intensification (RI)

    NASA Astrophysics Data System (ADS)

    Zhu, Z.; Zhu, P.

    2010-12-01

    It has long been recognized that the microphysics scheme used in a numerical simulation of tropical cyclones (TC) can greatly affect the precipitation distribution, intensity and thermodynamic structure of the simulated TC. This suggests that the mixing ratios, concentrations and size distributions of hydrometeor(snow, graupel,rain,cloud ice) are important factors in the evolution of TC . The transport of hydrometeor may have a strong influence on these factors through its interactions with the growth and the latent heat forcing of hydrometeor and the wind filed, hence is a key to understanding TC microphysics. Schematic hydrometeor trajectories were first constructed using 3-D wind field and particle fallspeeds derived from airborne radar observations in a steady-state mature hurricane,Alicia(1983). Since then, little effort has been put in understanding hydrometeor transport in TC, especially the potential link between its evolution and the intensity and structure changes in a non-steady-state TC. This study is focused on investigating such a link by means of numerical simulations of TC Rapid Intensification(RI) using WRF model. We use the tracer utility in WRF to construct hydrometeor trajectories. Most of the popular microphysics schemes are tested, and the most reasonable test( which is determined by comparing the simulated TC intensity and structure with airborne radar observations) and the ensemble mean of all the tests are picked for detailed examinations.

  12. Tc-99m tilmanocept versus Tc-99m sulfur colloid in breast cancer sentinel lymph node identification: Results from a randomized, blinded clinical trial.

    PubMed

    Unkart, Jonathan T; Hosseini, Ava; Wallace, Anne M

    2017-12-01

    No prior trials have compared sentinel lymph node (SLN) identification outcomes between Tc-99m tilmanocept (TcTM) and Tc-99m sulfur colloid (TcSC) in breast cancer (BC). We report on the secondary outcomes from a randomized, double-blinded, single surgeon clinical trial comparing post-injection site pain between TcTM and TcSC. Patients were randomized to receive a preoperative single, peritumoral intradermal injection of TcTM or TcSC. The number of total, "hot", and blue nodes detected and removed were compared between groups. Fifty-two (27-TcSC and 25-TcTM) patients were enrolled and underwent definitive surgical treatment. At least one "hot" SLN was detected in all patients. Three (5.8%) patients had a disease positive-SLN. The total number of SLNs removed was 61 (mean 2.26 (standard deviation (SD) 0.90)) in the TcSC group and 54 (mean 2.16 (SD 0.90)) in the TcTM group, P = 0.69. The total number of "hot" nodes in the TcSC group was 1.96 (SD 0.76) compared to 2.04 (SD 0.73) in the TcTM group, P = 0.71. The number of identified SLNs did not differ significantly between TcTM and TcSC. Given that no significant technical advantages exist between the two agents, surgeons should choose a radiopharmaceutical based on cost and side effect profile. © 2017 Wiley Periodicals, Inc.

  13. The use of 99mTc-Al2O3 for detection of sentinel lymph nodes in cervical cancer patients

    NASA Astrophysics Data System (ADS)

    Sinilkin, I. G.; Chernov, V. I.; Lyapunov, A. Yu; Medvedeva, A. A.; Zelchan, R. V.; Chernyshova, A. L.; Kolomiets, L. A.

    2016-06-01

    The purpose of the study was to evaluate the feasibility of using 99mTc-Al2O3- based radiopharmaceutical, a novel molecular imaging agent for sentinel lymph node detection in patients with invasive cervical cancer. The study included 23 cervical cancer patients (TlaNxMx- T2bNxMx) treated at the Tomsk Cancer Research Institute. At 18 hours before surgery, 80 MBq of the 99mTc-Al2O3 were injected peritumorally, followed by single-photon emission computed tomography (SPECT) of the pelvis and intraoperative SLN identification. Twenty-seven SLNs were detected by SPECT, and 34 SLNs were identified by intraoperative gamma probe. The total number of identified SLNs per patient ranged from 1 to 3(the mean number of SLNs was 1.4 per patient). The most common site for SLN detection was the external iliac region (57.2%), followed by the internal iliac, obturator, presacral and retrosacral regions (they amounted to 14%, respectively),and the parametrial region (1%). Sensitivity in detecting SLNs was 100% for intraoperative SLN identification and 79% for SPECT image.

  14. Spatial Characterization of Polycyclic Aromatic Hydrocarbons in 2008 TC3 Samples

    NASA Astrophysics Data System (ADS)

    Sabbah, Hassan; Morrow, A.; Zare, R. N.; Jenniskens, P.

    2009-09-01

    Hassan Sabbah1, Amy L. Morrow1, Richard N. Zare1 and Petrus Jenniskens2 1Stanford University, Stanford, California 94305, 2 SETI Institute, Carl Sagan Center, 515 North Whisman Road, Mountain View, California 94043, USA. In October 2006 a small asteroid (2-3 meters) was observed in outer space. On October 7, 2008, it entered the Earth's atmosphere creating a fireball over Northern Sudan. Some 280 meteorites were collected by the University of Khartoum. In order to explore the existence of organic materials, specifically polycyclic aromatic hydrocarbons (PAHs), we applied two-step laser desorption laser ionization mass spectrometry (L2MS) to some selected fragments. This technique consists of desorbing with a pulsed infrared laser beam the solid materials into a gaseous phase with no fragmentation followed by resonance enhanced multiphoton ionization to analyze the PAH content. L2MS was already applied to an array of extraterrestrial objects including interplanetary dust particles IDPs, carbonaceous chondrites and comet coma particles. Moreover, spatial resolution of PAHs in 2008 TC3 samples was achieved to explore the heterogeneity within individual fragments. The results of these studies and their contribution to understanding the formation of this asteroid will be discussed.

  15. Imaging experimental intraabdominal abscesses with 99mTc-PEG liposomes and 99mTc-HYNIC IgG.

    PubMed Central

    Dams, E T; Reijnen, M M; Oyen, W J; Boerman, O C; Laverman, P; Storm, G; van der Meer, J W; Corstens, F H; van Goor, H

    1999-01-01

    OBJECTIVE: To evaluate the accuracy of technetium-99m-labeled polyethylene glycol-coated liposomes (99mTc-PEG liposomes) and technetium-99m-labeled nonspecific human immunoglobulin G (99mTc-HYNIC IgG) for the scintigraphic detection of experimental intraabdominal abscesses in comparison with that of a standard agent, gallium-67 citrate. BACKGROUND: Scintigraphic imaging techniques can be very useful for the rapid and accurate localization of intraabdominal abscesses. Two newly developed radiolabeled agents, 99mTc-PEG liposomes and 99mTc-HYNIC IgG, have shown to be excellent agents for imaging experimental focal infection, but have not yet been studied in the detection of abdominal abscesses. METHODS: Intraabdominal abscesses were induced in 42 rats using the cecal ligation and puncture technique. Seven days later, randomized groups of rats received 99mTc-PEG liposomes, 99mTc-HYNIC IgG, or 67Ga citrate intravenously. The rats were imaged up to 24 hours after the injection. The biodistribution of the radiolabel was determined by counting dissected tissues ex vivo. Macroscopic intraabdominal abnormalities and focal uptake on the images were independently scored on a semiquantitative scale. RESULTS: 99mTc-PEG liposomes provided the earliest scintigraphic visualization of the abscess (as soon as 2 hours after the injection vs. 4 hours for the other two agents). Liposomes, IgG, and gallium all showed similarly high absolute uptake in the abscess. Focal uptake of liposomes and gallium correlated best with the extent of the macroscopic abnormalities. CONCLUSIONS: 99mTc-PEG liposomes and 99mTc-HYNIC IgG performed at least as well as the standard agent, 67Ga citrate, in the detection of experimental intraabdominal abscesses, with obvious advantages such as lower radiation exposure and more favorable physical properties. Of the two technetium agents, the liposomes seemed to be superior, providing the earliest diagnostic image and the best correlation with the inflammatory

  16. /sup 99m/Tc-fibrinogen scanning in adult respiratory distress syndrome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Quinn, D.A.; Carvalho, A.C.; Geller, E.

    1987-01-01

    Fibrin is often seen occluding the lung vessels of patients dying from ARDS and is surrounded by regions of lung necrosis. To learn if we could observe increased or focal fibrin deposition and assess the kinetics of plasma fibrinogen turnover during severe acute respiratory failure, we injected technetium 99m-labeled human purified fibrinogen (Tc-HF) and used gamma camera scanning for as long as 12 h in 13 sequential patients as soon as possible after ICU admission. The fibrinogen uptake rates were determined by calculating the lung:heart radioactivity ratios at each time point. Slopes of the lung:heart ratio versus time were comparedmore » between ARDS and mild acute respiratory failure (ARF). The slope of the lung:heart Tc-HF ratio of the 9 patients with ARDS (2.9 +/- 0.4 units) was markedly higher (p less than 0.02) than the slope of the 4 patients with mild ARF (1.1 +/- 0.4) and the 3 patients studied 5 to 9 months after recovery from respiratory failure (0.7 +/- 0.07). In the 1 patient with ARDS and the 2 patients with mild ARF studied both during acute lung injury and after recovery, the lung:heart Tc-HF ratio had decreased at recovery. To compare the pulmonary uptake of Tc-HF to /sup 99m/Tc-labeled human serum albumin (Tc-HSA), 5 patients were injected with 10 mCi of Tc-HSA, and scanning of the thorax was performed with a similar sequential imaging protocol 24 h after conclusion of the Tc-HF study.« less

  17. Differential Lung Uptake of 99mTc-HMPAO and 99mTc-Duramycin in the Chronic Hyperoxia Rat Model

    PubMed Central

    Clough, Anne V.; Audi, Said H.; Haworth, Steven T.; Roerig, David L.

    2015-01-01

    Noninvasive radionuclide imaging has the potential to identify and assess mechanisms involved in particular stages of lung injury which occur with acute respiratory distress syndrome, for example. Lung uptake of 99mTc-hexamethylpropyleneamine oxime (HMPAO) is reported to be partially dependent on the redox status of the lung tissue while 99mTc-duramycin, a new marker of cell injury, senses cell death via apoptosis and/or necrosis. Thus, we investigated changes in lung uptake of these agents in rat exposed to hyperoxia for prolonged periods, a common model of acute lung injury. Methods Male Sprague-Dawley rats were pre-exposed to either normoxia (21% O2) or hyperoxia (85% O2) for up to 21 days. For imaging, the rats were anesthetized, injected i.v. with either 99mTc-HMPAO or 99mTc-duramycin (37-74 MBq) and planar images were acquired using a high sensitivity modular gamma camera. Subsequently, 99mTc-macroagreggated albumin (37 MBq, diam=10-40 μm) was injected i.v., imaged, and used to define a lung region-of-interest. The lung to background ratio was used as a measure of lung uptake. Results Hyperoxia exposure resulted in a 74% increase in 99mTc-HMPAO lung uptake, which peaked at 7 days and persisted for the 21 days of exposure. 99mTc-duramycin lung uptake was also maximal at 7 days of exposure but decreased to near control levels by 21 days. The sustained elevation of 99mTc-HMPAO uptake suggests ongoing changes in lung redox status whereas cell death appears to have subsided by 21 days. Conclusion These results suggest the potential use of 99mTc-HMPAO and 99mTc-duramycin as redox and cell-death imaging biomarkers, respectively, for in vivo identification and assessment of different stages of lung injury. PMID:23086010

  18. A pilot study to evaluate the safety and feasibility of the administration of AZT/3TC fixed dose combination to HIV infected pregnant women and their infants in Rio de Janeiro, Brazil

    PubMed Central

    Lambert, J; Nogueira, S; Abreu, T; Machado, E; Costa, T; Bondarovsky, M; Andrade, M; Halpern, M; Barbosa, R; Perez, M

    2003-01-01

    Objectives: To evaluate the safety and feasibility of zidovudine and lamivudine (AZT/3TC) given to HIV infected pregnant women and their infants in Rio de Janeiro, Brazil. Methods: This open label phase II study enrolled 40 HIV infected antiretroviral naive women ⩾20 weeks gestation, CD4 <500 cells x106/l, from two public hospitals. Treatment: fixed dose AZT 300 mg/3TC 150 mg by mouth every 12 hours until labour; AZT 300 mg by mouth every 3 hours until delivery; infants: AZT 4 mg/kg every 12 hours plus 3TC 2 mg/kg every 12 hours for 6 weeks. Blood haematology and chemistry were monitored; adherence evaluated by pills count; efficacy measured by changes in lymphocyte (CD4) and viral load, and by HIV RNA-PCR tests performed at birth, 6 and 12 weeks, to diagnose infant infection. No women breast fed. Results: Patient characteristics: mean age 24.48 (SD 3.5) years; gestational age 24.5 (4.5) weeks; AZT/3TC duration 14.4 (4.4) weeks; vaginal delivery: 11/39; caesarean section: 28/39. Entry and pre-labour CD4: 310/486 cells x106/l (p<0.001); entry and pre-labour viral load: 53 818/2616 copies/ml (p<0.001). Thirty nine women tolerated treatment with >80% adherence; one was lost to follow up. Five newborns were excluded from 3TC receipt. All 39 babies were uninfected. Haematological toxicity in newborns was common: anaemia in 27; neutropenia in five (two severe); platelets counts <100 000 in two. All values recovered on study completion. Conclusions: Fixed dose AZT/3TC is well accepted, gives improvements in CD4 and viral load; no infants were HIV infected. Haematological toxicity in infants needs careful monitoring. PMID:14663118

  19. Effect of processing parameters on the characteristics of high-Tc superconductor YBa2Cu3Oy

    NASA Technical Reports Server (NTRS)

    Bansal, Narottam P.

    1988-01-01

    SEM, thermogravimetric analysis, powder X-ray diffraction,and measurements of electrical resistivity and magnetic susceptibility, are presently used to characterize the influence of sintering temperature, sintering and annealing atmospheres, and quench-rate on the properties of the YBa2Cu3Oy superconducting oxide. It is established that annealing in oxygen, together with slow cooling rates, are required for preparation of high-Tc superconductors with sharp transitions; rapid quenching from high temperature does not yield good superconductors, due to low oxygen content.

  20. Evaluation of [99mTc/EDDA/HYNIC0]octreotide derivatives compared with [111In-DOTA0,Tyr3, Thr8]octreotide and [111In-DTPA0]octreotide: does tumor or pancreas uptake correlate with the rate of internalization?

    PubMed

    Storch, Daniel; Béhé, Martin; Walter, Martin A; Chen, Jianhua; Powell, Pia; Mikolajczak, Renata; Mäcke, Helmut R

    2005-09-01

    Radiolabeled somatostatin analogs are important tools for the in vivo localization and targeted radionuclide therapy of somatostatin receptor-positive tumors. The aim of this study was to compare 3 somatostatin analogs designed for the labeling with (99m)Tc (where HYNIC is 6-hydrazinopyridine-3-carboxylic acid): 6-hydrazinopyridine-3-carboxylic acid(0)-octreotide (HYNIC-OC/(99m)Tc-(1)), [HYNIC(0),Tyr(3)]octreotide (HYNIC-TOC/(99m)Tc-(2)), and [HYNIC(0),Tyr(3),Thr(8)]octreotide (HYNIC-TATE/(99m)Tc-(3)), using ethylenediamine-N,N'-diacetic acid (EDDA) as a coligand. In addition, we compared the (99m)Tc-labeled peptides [(111)In-diethylenetriaminepentaacetic acid(0)]octreotide ([(111)In-DTPA]-OC) and [(111)In-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid(0),Tyr(3),Thr(8)]octreotide ([(111)In-DOTA]-TATE) with regard to the rate of internalization and the biodistribution in AR4-2J (expressing the somatostatin receptor subtype 2) tumor-bearing rats. The main attention was directed toward a potential correlation between the rate of internalization and the tumor or pancreas uptake. Synthesis was performed on solid phase using a standard Fmoc strategy. Internalization was studied in cell culture (AR4-2J) and biodistribution was studied using a Lewis rat tumor model (AR4-2J). The 5 radiopeptides showed a specific internalization into AR4-2J cells in culture (as shown by blocking experiments). The rate of internalization of the 5 radiopeptides differed significantly according to the following order: (99m)Tc-(1) approximately = [(111)In-DTPA]-OC < (99m)Tc-(2) < (99m)Tc-(3) approximately = [(111)In-DOTA]-TATE. All radiopeptides displayed a rapid blood clearance and a fast clearance from all somatostatin receptor-negative tissues predominantly via the kidneys. A receptor-specific uptake of radioactivity was observed for all compounds in somatostatin receptor-positive organs such as the pancreas, the adrenals, and the stomach. After 4 h, the uptake in the AR4-2J tumor

  1. Radiolabeling of rituximab with (188)Re and (99m)Tc using the tricarbonyl technology.

    PubMed

    Dias, Carla Roberta; Jeger, Simone; Osso, João Alberto; Müller, Cristina; De Pasquale, Christine; Hohn, Alexander; Waibel, Robert; Schibli, Roger

    2011-01-01

    The most successful clinical studies of immunotherapy in patients with non-Hodgkin's lymphoma (NHL) use the antibody rituximab (RTX) targeting CD20(+) B-cell tumors. Rituximab radiolabeled with β(-) emitters could potentiate the therapeutic efficacy of the antibody by virtue of the particle radiation. Here, we report on a direct radiolabeling approach of rituximab with the (99m)Tc- and (188)Re-tricarbonyl core (IsoLink technology). The native format of the antibody (RTX(wt)) as well as a reduced form (RTX(red)) was labeled with (99m)Tc/(188)Re(CO)(3). The partial reduction of the disulfide bonds to produce free sulfhydryl groups (-SH) was achieved with 2-mercaptoethanol. Radiolabeling efficiency, in vitro human plasma stability as well as transchelation toward cysteine and histidine was investigated. The immunoreactivity and binding affinity were determined on Ramos and/or Raji cells expressing CD20. Biodistribution was performed in mice bearing subcutaneous Ramos lymphoma xenografts. The radiolabeling efficiency and kinetics of RTX(red) were superior to that of RTX(wt) ((99m)Tc: 98% after 3 h for RTX(red) vs. 70% after 24 h for RTX(wt)). (99m)Tc(CO)(3)-RTX(red) was used without purification for in vitro and in vivo studies whereas (188)Re(CO)(3)-RTX(red) was purified to eliminate free (188)Re-precursor. Both radioimmunoconjugates were stable in human plasma for 24 h at 37 °C. In contrast, displacement experiments with excess cysteine/histidine showed significant transchelation in the case of (99m)Tc(CO)(3)-RTX(red) but not with pre-purified (188)Re(CO)(3)-RTX(red). Both conjugates revealed high binding affinity to the CD20 antigen (K(d) = 5-6 nM). Tumor uptake of (188)Re(CO)(3)-RTX(red) was 2.5 %ID/g and 0.8 %ID/g for (99m)Tc(CO)(3)-RTX(red) 48 h after injection. The values for other organs and tissues were similar for both compounds, for example the tumor-to-blood and tumor-to-liver ratios were 0.4 and 0.3 for (99m)Tc(CO)(3)-RTX(red) and for (188)Re(CO)(3)-RTX

  2. Limitations and pitfalls of 99mTc-EDDA/HYNIC-TOC (Tektrotyd) scintigraphy.

    PubMed

    Garai, Ildikó; Barna, Sandor; Nagy, Gabor; Forgacs, Attila

    2016-01-01

    Tektrotyd kit was developed by Polatom company for 99mTc labeling to make an alternative tracer of somatostatin receptor scintigraphy available. Since 2005, 99mTc-EDDA/HYNIC-Tyr3-Octreotide has been used in clinical imaging and achieved high impact in management of patients with neuroendocrine tumors. Knowing the limitations and pitfalls is essential to provide ac-curate diagnosis. Therefore, the potential pitfalls associated with the use of 99mTc-EDDA/HYNIC-TOC are reviewed on the basis of own experience. Data were analyzed of 310 patients who underwent somatostatin receptor scintigraphy with 99mTc-Tektrotyd. Pitfalls during radiolabeling process or acquisition can worsen the sensitivity of SRS (somatostatin receptor scintigraphy). Recognizing physi-ological and clinical pitfalls, the diagnostic accuracy will improve.

  3. High Tc superconducting films from metallo-organic precursors

    NASA Astrophysics Data System (ADS)

    Davison, W. W.; Shyu, S. G.; Buchanan, R. C.

    High Tc superconducting films of heavy metal soaps (derived from carboxylic acid precursors) have been prepared on Si and other substrates. The precursors were synthesized and mixed in appropriate molar ratios to form the high Tc compound YBa2Cu3O(7-x), using a high boiling point common solvent base. The precursor solution was deposited by a spin casting technique on the substrates. Film thicknesses of 0.1-1.0 micron were achieved after heat treatment at 550-850 C at not longer than 4 hours. Films were analyzed as to orientation, appropriate phase, interfacial reaction, and superconducting properties.

  4. Initial evaluation of 99m Tc-tricarbonyl-cyclopentadienyl fatty acids derivatives as SPECT tracers for myocardium.

    PubMed

    Liu, Jianping; Wang, Huan; Wang, Shuxia; Xue, Qianqian; Wang, Dawei; Wang, Hang; Zhang, Huabei

    2017-05-15

    Fatty acids are myocardial metabolic agent for detecting myocardial ischemia and infraction. However, no 99m Tc-labeled fatty acids had potential use in clinical practice. In this study, 99m Tc-CpTT-10-oxo-para-PPA (1d), 99m Tc-CpTT-11-oxo-para-PPA (2d), 99m Tc-CpTT-12-oxo-para-PPA (3d), 99m Tc-CpTT-11-oxo-ortho-PPA (4d), and 99m Tc-CpTT-11-oxo-meta-PPA (5d) were synthesized by a double ligand transfer reaction, and their biological behaviors were investigated. Compound 2d achieved good heart to blood ratio (3.39 at 5 min after intravenous), and 2d showed high-heart uptake of 6.20% ID/g at 5 minutes after injection. Compound 3d displayed a prolonged retention in the myocardium (1.43% ID/g at 60 min after injection). Radioactivity accumulation in the lungs, spleen, and blood was eliminated rapidly. In vivo, metabolite analysis presented that compound 6d may be metabolite of 2d through β-oxidation in tissue. Unfortunately, the biodistribution studies of 1d, 2d, 3d, 4d, and 5d showed fast heart clearance and poor heart to liver ratios, which suggested that the 5 99m Tc-labeled fatty acid analogues cannot be used for diagnosis. Copyright © 2017 John Wiley & Sons, Ltd.

  5. AZ-2000-IECW and StaMet Black Kapton Options for Solar Probe Plus MAG Sensor MLI Kevlar/Polyimide Shells

    NASA Technical Reports Server (NTRS)

    Choi, Michael K.

    2017-01-01

    AZ-2000-IECW white paint and StaMet black Kapton have been evaluated for the Kevlar/polyimide shells that enclose the Solar Probe Plus Magnetometer (MAG) sensors and multilayer insulation. Flight qualification testing on AZ-2000-IECW painted Kevlar/polyimide laminate was completed at Goddard Space Flight Center. This paint potentially meets all the requirements. However, it has no flight heritage. StaMet is hotter in the sun, and is specular. The results of the MAG thermal balance test show StaMet meets the thermal requirement and heater power budget. The mission prefers to fly StaMet after evaluating the risks of AZ-2000-IECW flaking and glint from StaMet to the Star Trackers.

  6. Newly Calibrated Observations from the MagEIS Proton Telescopes Aboard the Van Allen Probes

    NASA Astrophysics Data System (ADS)

    Looper, M. D.; Claudepierre, S. G.; O'Brien, T. P.; Blake, J. B.; Fennell, J. F.; Guild, T. B.; Mazur, J. E.

    2017-12-01

    In addition to electron detectors, the MagEIS (Magnetic Electron Ion Spectrometer) sensors aboard the Van Allen Probes include telescopes designed to measure protons from about 60 keV to 20 MeV. While both MagEIS telescopes measure protons in the 60-1200 keV energy range, the telescope on Van Allen Probe B houses an additional detector that measures protons in the 1-20 MeV energy range. With the addition of the 1-20 MeV proton measurements, these telescopes bridge the energy ranges of the HOPE and REPT sensors that are also part of the Energetic Particle, Composition, and Thermal Plasma (ECT) sensor suite. We have used the Geant4 radiation-transport code to model the response of the proton telescopes, including backgrounds, and have used this new understanding to prepare a calibrated dataset of their measurements. The newly-calibrated 1-20 MeV proton measurements will be made available to the community for the first time as part of an upcoming ECT data release. We present results from this new dataset during geomagnetically active periods when changes are observed in the outer regions of the inner zone.

  7. Birotor dipole model for Saturn's inner magnetic field from CASSINI RPWS measurements and MAG data

    NASA Astrophysics Data System (ADS)

    Galopeau, Patrick H. M.

    2016-10-01

    The radio and plasma wave science (RPWS) experiment on board the Cassini spacecraft, orbiting around Saturn since July 2004, revealed the presence of two distinct and variable rotation periods in the Saturnian kilometric radiation (SKR). These two periods were attributed to the northern and southern hemispheres respectively. The existence of a double period makes the study of the planetary magnetic field much more complicated and the building of a field model, based on the direct measurements of the MAG experiment from the magnetometers embarked on board Cassini, turns out to be uncertain. The first reason is the difficulty for defining a longitude system linked to the variable period, because the internal magnetic field measurements from MAG are not continuous. The second reason is the existence itself of two distinct periods which could imply the existence of a double rotation magnetic structure generated by Saturn's dynamo. However, the radio observations from the RPWS experiment allow a continuous and accurate follow-up of the rotation phase of the variable two periods, since the SKR emission is permanently observable and produced very close to the planetary surface. A wavelet transform analysis of the intensity of the SKR signal received at 290 kHz was performed in order to calculate the rotation phase of each Saturnian hemisphere. A dipole model was proposed for Saturn's inner magnetic field: this dipole presents the particularity to rotate around Saturn's axis at two different angular velocities; it is tilted and not centered. Then it is possible to fit the MAG data for each Cassini's revolution around the planet the periapsis of which is less than 5 Saturnian radii. This study suggests that Saturn's inner magnetic field is neither stationary nor fully axisymmetric. Such a result can be used as a boundary condition for modelling and constraining the planetary dynamo.

  8. Evaluation of (99)  (m)TcN-MPO as a new myocardial perfusion imaging agent in normal dogs and in an acute myocardial infarction canine model: comparison with (99)  (m)Tc-sestamibi.

    PubMed

    Bu, Lihong; Li, Renfei; Jin, Zhongnan; Wen, Xiaofei; Liu, Shuang; Yang, Baofeng; Shen, Baozhong; Chen, Xiaoyuan

    2011-02-01

    (99)  (m)TcN-MPO ([(99)  (m)TcN(mpo)(PNP5)](+): mpo = 2-mercaptopyridine oxide and PNP5 = N-ethoxyethyl-N,N-bis[2-(bis(3-methoxypropyl)phosphino)ethyl]amine) is a cationic (99)  (m)Tc-nitrido complex, which has favorable biodistribution and myocardial uptake with rapid liver clearance in Sprague Dawley rats. The objective of this study was to compare the biodistribution and pharmacokinetics of (99)  (m)TcN-MPO and (99)  (m)Tc-Sestamibi in normal dogs, and to evaluate the potential of (99)  (m)TcN-MPO as a myocardial perfusion agent in canines with acute myocardial infarction. Five normal mongrel dogs were injected intravenously with (99)  (m)TcN-MPO. Venous blood samples were collected via a femoral vein catheter at 0.5, 1, 2, 3, 4, 5, 10, 20, 30, 40, 60, and 90 min post-injection (p.i.). Anterior-posterior planar images were acquired by γ-camera at 10, 20, 30, 60, 90, and 120 min p.i. Regions of interest (ROIs) were drawn around the heart, liver, and lungs. The heart/liver and heart/lung ratios were calculated by dividing the mean counts in heart ROI by the mean counts in the liver and lung ROI, respectively. For comparison, (99)  (m)Tc-sestamibi was also evaluated in the same five dogs. The interval period between the two examinations was 1 week to eliminate possible interference between these two radiotracers. In addition, single positron emission computed tomography (SPECT) images in the canine infarct model were collected 24 h after myocardial infarction at 30 and 60 min after the administration of (99)  (m)TcN-MPO (n = 4) or (99)  (m)Tc-Sestamibi (n = 4). It was found that (99)  (m)TcN-MPO and (99)  (m)Tc-Sestamibi displayed very similar blood clearance characteristics during the first 90 min p.i. Both (99)  (m)TcN-MPO and (99)  (m)Tc-Sestamibi had a rapid blood clearance with less than 50% of initial radioactivity remaining at 1 min and less than 5% at 30 min p.i. (99)  (m)TcN-MPO and (99)  (m)Tc-Sestamibi both showed good

  9. Synthesis and characterization of fac-[M(CO)3(P)(OO)] and cis-trans-[M(CO)2(P)2(OO)] complexes (M = Re, (99m)Tc) with acetylacetone and curcumin as OO donor bidentate ligands.

    PubMed

    Triantis, Charalampos; Tsotakos, Theodoros; Tsoukalas, Charalampos; Sagnou, Marina; Raptopoulou, Catherine; Terzis, Aris; Psycharis, Vassilis; Pelecanou, Maria; Pirmettis, Ioannis; Papadopoulos, Minas

    2013-11-18

    The synthesis and characterization of neutral mixed ligand complexes fac-[M(CO)3(P)(OO)] and cis-trans-[M(CO)2(P)2(OO)] (M = Re, (99m)Tc), with deprotonated acetylacetone or curcumin as the OO donor bidentate ligands and a phosphine (triphenylphosphine or methyldiphenylphosphine) as the monodentate P ligand, is described. The complexes were synthesized through the corresponding fac-[M(CO)3(H2O)(OO)] (M = Re, (99m)Tc) intermediate aqua complex. In the presence of phosphine, replacement of the H2O molecule of the intermediate complex at room temperature generates the neutral tricarbonyl monophosphine fac-[Re(CO)3(P)(OO)] complex, while under reflux conditions further replacement of the trans to the phosphine carbonyl generates the new stable dicarbonyl bisphosphine complex cis-trans-[Re(CO)2(P)2(OO)]. The Re complexes were fully characterized by elemental analysis, spectroscopic methods, and X-ray crystallography showing a distorted octahedral geometry around Re. Both the monophosphine and the bisphosphine complexes of curcumin show selective binding to β-amyloid plaques of Alzheimer's disease. At the (99m)Tc tracer level, the same type of complexes, fac-[(99m)Tc(CO)3(P)(OO)] and cis-trans-[(99m)Tc(CO)2(P)2(OO)], are formed introducing new donor combinations for (99m)Tc(I). Overall, β-diketonate and phosphine constitute a versatile ligand combination for Re(I) and (99m)Tc(I), and the successful employment of the multipotent curcumin as β-diketone provides a solid example of the pharmacological potential of this system.

  10. Laser propagation through full-scale, high-gain MagLIF gas pipes using the NIF

    NASA Astrophysics Data System (ADS)

    Pollock, Bradley; Sefkow, Adam; Goyon, Clement; Strozzi, David; Khan, Shahab; Rosen, Mordy; Campbell, Mike; Logan, Grant; Peterson, Kyle; Moody, John

    2016-10-01

    The first relevant measurements of laser propagation through surrogate high-gain MagLIF gas pipe targets at full scale have been performed at the NIF, using 30 kJ of laser drive from one quad in a 10 ns pulse at an intensity of 2e14 W/cm2. The unmagnetized pipe is filled with 1 atm of 99%/1% neopentane/Ar, and uses an entrance window of 0.75 um polyimide and an exit window of 0.3 um of Ta backed with 5 um of polyimide. Side-on x-ray emission from the plasma is imaged through the 100 um-thick epoxy wall onto a framing camera at four times during the drive, and is in excellent agreement with pre-shot HYDRA radiation-hydrodynamics modeling. X-ray emission from the Ta exit plane is imaged onto a streak camera to determine the timing and intensity of the laser burning through the pipe, and the Ar emission from the center of the pipe is spectrally- and temporally-resolved to determine the plasma electron temperature. Backscatter is measured throughout the laser drive, and is found to be of significance only when the laser reaches the Ta exit plane and produces SBS. These first results in unmagnetized surrogate gas fills are encouraging since they demonstrate sufficient laser energy absorption and low LPI losses within high-density long-scale-length plasmas for proposed high-gain MagLIF target designs. We will discuss plans to magnetize targets filled with high-density DT gas in future experiments. This work performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the National Nuclear Security Administration under Contract No. DE-AC04-94AL85000.

  11. Evaluation of 99mTc labeled diadenosine tetraphosphate as an atherosclerotic plaque imaging agent in experimental models.

    PubMed

    Cao, Wei; Zhang, Yongxue; An, Rui

    2006-01-01

    The potential of 99mTc labeled P1, P4-di (adenosine-5')-tetraphosphate (Ap4A) for imaging experimental atherosclerotic plaques was evaluated in New Zealand white (NZW) rabbits. To label the 99mTc to Ap4A, stannous tartrate solution was used. 99mTc-Ap4A was purified on a Sephadex G-25 column. The radiochemistry purities of 99mTc-Ap4A were 85% to 91%. Biodistribution study revealed 99mTc-Ap4A cleared from blood rapidly. Thirty min after 99mTc-Ap4A administrated on NZW atherosclerotic rabbits, lesion to blood (target/blood, T/B) ratio was 3.17 +/- 1.27, and lesions to normal (target/non-target, T/NT) ratio was 5.23 +/- 1.87. Shadows of atherosclerotic plaques were clearly visible on radioautographic film. Aortas with atherosclerotic plaques also could be seen on ex vivo gamma camera images. Atherosclerotic abdominal aortas were clearly visible on in vivo images 15 min to 3 h after 99mTc-Ap4A administration. 99mTc-labeled Ap4A can be used for rapid noninvasive detection of experimental atherosclerotic plaque.

  12. Preparation and biological evaluation of [(99m)Tc/EDDA/Tricine/HYNIC(0), BzThi(3)]-octreotide for somatostatin receptor-positive tumor imaging.

    PubMed

    Erfani, Mostafa; Shafiei, Mohammad; Mazidi, Mohammad; Goudarzi, Mostafa

    2013-04-01

    Somatostatin-derived analogues play an important role in the diagnosis and treatment of neuroendocrine tumors. The aim of this study was to evaluate a new somatostatin analogue designed for labeling with (99m)Tc: [6-hydrazinopyridine-3-carboxylic acid (HYNIC(0)), β-(3-benzothienyl)-Ala (BzThi(3))]-octreotide ([HYNIC]-BOC), using ethylenediamine-N,N'-diacetic acid (EDDA) and tricine as coligands. Synthesis was performed on a solid phase using a standard Fmoc strategy. The HYNIC-peptide conjugate was radiolabeled with (99m)Tc and characterized by ITLC and high-performance liquid chromatography (HPLC). In vitro studies were carried out in sstr2 expressing AR4-2J cell lines. In vivo distribution studies were performed in rats bearing the AR4-2J tumor. The radiolabeled complex could be prepared at high-specific activities and >95% radiochemical yield as determined by HPLC. The peptide conjugate showed high-affinity binding for sstr2. The radioligand showed high and specific internalization into AR4-2J cells (18.19%±0.21% at 4 hours). In vivo distribution studies in rats bearing tumor have shown a receptor-specific uptake of radioactivity in somatostatin receptor-positive organs. After 4 hours, uptake in the AR4-2J tumor was 1.71%±0.36% injected dose per gram tissue (%ID/g). These data show that [(99m)Tc/EDDA/Tricine/HYNIC(0), BzThi(3)]-octreotide is a specific radioligand for the somatostatin receptor-positive tumors and is a suitable candidate for clinical studies.

  13. (99m)Tc-HYNIC-TOC scintigraphy in evaluation of active Graves' ophthalmopathy (GO).

    PubMed

    Sun, Hua; Jiang, Xu-Feng; Wang, Shu; Chen, Hao-Yan; Sun, Jiao; Li, Pei-Yong; Ning, Guang; Zhao, Yong-Ju

    2007-06-01

    A promising radiopharmaceutical (99m)Tc-HYNIC-TOC ((99m)Tc-HYNIC-Octreotide) can be applied for somatostatin receptor scintigraphy with the potential to replace Indium-111 labeled somatostatin analogus. Here we evaluate whether orbital (99m)Tc-HYNIC-TOC scintigraphy can be used as a Graves' ophthalmopathy (GO) activity parameter to predict the retrobulbar irradiation response. Orbital (99m)Tc-HYNIC-TOC scintigraphy was performed on 14 consecutive patients demonstrating moderated to severe Graves' ophthalmopathy. The patients were treated with retrobulbar irradiation following the octreoscan and the response to this therapy was assessed at 3 months after the start of treatment. The orbital (99m)Tc-HYNIC-TOC uptake was calculated to assess the effects of treatment. Among the 14 GO patients, eight (57.1%) responded to retrobulbar radiotherapy; six (42.9%) showed no change. We compared the eight responders and six non-responders in terms of orbital (99m)Tc-HYNIC-TOC uptake, using the orbital/occipital ratio. On the 4-h (99m)Tc-HYNIC-TOC scintigraphy, responders had a higher orbital/occipital uptake ratio than the no-responders (P = 0.001). A significant correlation was found between the orbital/occipital ratio and the clinical activity score (CAS) (P = 0.034). The Receiving-Operator-Characteristic curve showed the best threshold for discriminating active and inactive disease was 1.40 (sensitivity, 100%; specificity, 83.3%). In the responders group, all these eight patients had positive scintigraphy. While there were five patients who had negative scintigraphy in the non-responders group. Orbital (99m)Tc-HYNIC-TOC scintigraphy can be a useful method for the estimation of disease activity and prediction the response to subsequent radiotherapy in GO patient. And the patients with positive octreoscan were more likely to respond to irradiation.

  14. Epitaxial effects in thin films of high-Tc cuprates with the K2NiF4 structure

    NASA Astrophysics Data System (ADS)

    Naito, Michio; Sato, Hisashi; Tsukada, Akio; Yamamoto, Hideki

    2018-03-01

    La2-xSrxCuO4 (LSCO) and La2-xBaxCuO4 (LBCO) have been recognized as the archetype materials of "hole-doped" high-Tc superconductors. Their crystal structures are relatively simple with a small number of constituent cation elements. In addition, the doping level can be varied by the chemical substitution over a wide range enough to obtain the full spectrum of doping-dependent electronic and magnetic properties. These attractive features have dedicated many researchers to thin-film growth of LSCO and LBCO. The critical temperature (Tc) of LSCO and LBCO is sensitive to strain as manifested by a positive pressure coefficient of Tc in bulk samples. In general, films are strained if they are grown on lattice-mismatched substrates (epitaxial strain). Early attempts (before 1997) at the growth of LSCO and LBCO films resulted in depressed Tc below 30 K as they were grown on a commonly used SrTiO3 substrate (in-plane lattice parameter asub = 3.905 Å): the in-plane lattice parameters of LSCO and LBCO are ≤3.80 Å, and hence tensile epitaxial strain is introduced. The situation was changed by the use of LaSrAlO4 substrates with a slightly shorter in-plane lattice constant (asub = 3.756 Å). On LaSrAlO4 substrates, the Tc reaches 45 K in La1.85Sr0.15CuO4, 47 K in La1.85Ba0.15CuO4, and 56 K in ozone-oxidized La2CuO4+δ films, substantially higher than the Tc's of the bulk compounds. The Tc increase in La1.85Sr0.15CuO4 films on LaSrAlO4 and decrease on SrTiO3 are semi-quantitatively in accord with the phenomenological estimations based on the anisotropic strain coefficients of Tc (dTc/dεi). In this review article, we describe the growth and properties of films of cuprates having the K2NiF4 structure, mainly focusing on the increase/decrease of Tc by epitaxial strain and quasi-stable phase formation by epitaxial stabilization. We further extract the structural and/or physical parameters controlling Tc toward microscopic understanding of the variation of Tc by epitaxial strain.

  15. Melanoma targeting with alpha-melanocyte stimulating hormone analogs labeled with fac-[99mTc(CO)3]+: effect of cyclization on tumor-seeking properties.

    PubMed

    Raposinho, Paula D; Xavier, Catarina; Correia, João D G; Falcão, Soraia; Gomes, Paula; Santos, Isabel

    2008-03-01

    Early detection of primary melanoma tumors is essential because there is no effective treatment for metastatic melanoma. Several linear and cyclic radiolabeled alpha-melanocyte stimulating hormone (alpha-MSH) analogs have been proposed to target the melanocortin type 1 receptor (MC1R) overexpressed in melanoma. The compact structure of a rhenium-cyclized alpha-MSH analog (Re-CCMSH) significantly enhanced its in vivo tumor uptake and retention. Melanotan II (MT-II), a cyclic lactam analog of alpha-MSH (Ac-Nle-cyclo[Asp-His-DPhe-Arg-Trp-Lys]-NH2]), is a very potent and stable agonist peptide largely used in the characterization of melanocortin receptors. Taking advantage of the superior biological features associated with the MT-II cyclic peptide, we assessed the effect of lactam-based cyclization on the tumor-seeking properties of alpha-MSH analogs by comparing the pharmacokinetics profile of the 99mTc-labeled cyclic peptide betaAla-Nle-cyclo[Asp-His-D-Phe-Arg-Trp-Lys]-NH2 with that of the linear analog betaAla-Nle-Asp-His-DPhe-Arg-Trp-Lys-NH2 in melanoma-bearing mice. We have synthesized and coupled the linear and cyclic peptides to a bifunctional chelator containing a pyrazolyl-diamine backbone (pz) through the amino group of betaAla, and the resulting pz-peptide conjugates were reacted with the fac-[99mTc(CO)3]+ moiety. The 99mTc(CO)3-labeled conjugates were obtained in high yield, high specific activity, and high radiochemical purity. The cyclic 99mTc(CO)3-labeled conjugate presents a remarkable internalization (87.1% of receptor-bound tracer and 50.5% of total applied activity, after 6 h at 37 degrees C) and cellular retention (only 24.7% released from the cells after 5 h) in murine melanoma B16F1 cells. A significant tumor uptake and retention was obtained in melanoma-bearing C57BL6 mice for the cyclic radioconjugate [9.26 +/- 0.83 and 11.31 +/- 1.83% ID/g at 1 and 4 h after injection, respectively]. The linear 99mTc(CO)3-pz-peptide presented lower values for

  16. Novel Approach to Prepare {sup 99m}Tc-Based Multivalent RGD Peptides

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shuang Liu

    2012-10-24

    This project presents a novel approach to prepare the {sup 99m}Tc-bridged multivalent RGD (arginine-glycine-aspartate) peptides. This project will focus on fundamentals of {sup 99m}Tc radiochemistry. The main objective of this project is to demonstrate the proof-of-principle for the proposed radiotracers. Once a kit formulation is developed for preparation of the {sup 99m}Tc-bridged multivalent RGD peptides, various tumor-bearing animal models will be used to evaluate their potential for SPECT (single photon-emission computed tomography) imaging of cancer. We have demonstrated that (1) multimerization of cyclic RGD peptides enhances the integrin {alpha}{sub v}{beta}{sub 3} bonding affinity and radiotracer tumor uptake; (2) addition ofmore » G{sub 3} or PEG{sub 4} linkers makes it possible for two RGD motifs in 3P-RGD{sub 2} and 3G-RGD{sub 2} to achieve simultaneous integrin {alpha}{sub v}{beta}{sub 3} binding; and (3) multimers are actually bivalent (not multivalent), the presence of extra RGD motifs can enhance the tumor retention time of the radiotracer.« less

  17. 99mTc-labeling of HYNIC-conjugated cyclic RGDfK dimer and tetramer using EDDA as coligand.

    PubMed

    Wang, Jianjun; Kim, Young-Seung; Liu, Shuang

    2008-03-01

    In this study, EDDA (ethylenediamine- N, N'-diacetic acid) was used as the coligand for 99mTc-labeling of cyclic RGDfK conjugates: HYNIC-dimer (HYNIC = 6-hydrazinonicotinamide; dimer = E[c(RGDfK)]2) and HYNIC-tetramer (tetramer = E{E[c(RGDfK)]2}2). First, HYNIC-dimer was allowed to react with 99mTcO4 (-) in the presence of excess tricine and stannous chloride to form the intermediate complex [99mTc(HYNIC-dimer)(tricine)2], which was then allowed to react with EDDA to afford [99mTc(HYNIC-dimer)(EDDA)] with high yield (>90%) and high specific activity ( approximately 8.0 Ci/micromol). Under the same radiolabeling conditions, the yield for [99mTc(HYNIC-tetramer)(EDDA)] was always <65%. The results from a mixed-ligand experiment show that there is only one EDDA bonding to the 99mTc-HYNIC core in [99mTc(HYNIC-dimer)(EDDA)]. The athymic nude mice bearing subcutaneous U87MG human glioma xenografts were used to evaluate the impact of EDDA coligand on the biodistribution characteristics and excretion kinetics of the 99mTc-labeled HYNIC-dimer and HYNIC-tetramer. Surprisingly, [99mTc(HYNIC-dimer)(EDDA)] and [99mTc(HYNIC-tetramer)(EDDA)] had almost identical tumor uptake over the 2 h period. The use of EDDA as coligand to replace tricine/TPPTS (TPPTS = trisodium triphenylphosphine-3,3',3''-trisulfonate) did not significantly change the uptake of the 99mTc-labeled HYNIC-dimer in noncancerous organs, such as the liver, kidneys, and lungs; but it did result in a significantly lower kidney uptake for the 99mTc-labeled HYNIC-tetramer due to faster renal excretion. It was also found that the radiotracer tumor uptake decreases in a linear fashion as the tumor size increases. The smaller the tumors are, the higher the tumor uptake is regardless of the identity of radiotracer.

  18. HiTC: exploration of high-throughput ‘C’ experiments

    PubMed Central

    Servant, Nicolas; Lajoie, Bryan R.; Nora, Elphège P.; Giorgetti, Luca; Chen, Chong-Jian; Heard, Edith; Dekker, Job; Barillot, Emmanuel

    2012-01-01

    Summary: The R/Bioconductor package HiTC facilitates the exploration of high-throughput 3C-based data. It allows users to import and export ‘C’ data, to transform, normalize, annotate and visualize interaction maps. The package operates within the Bioconductor framework and thus offers new opportunities for future development in this field. Availability and implementation: The R package HiTC is available from the Bioconductor website. A detailed vignette provides additional documentation and help for using the package. Contact: nicolas.servant@curie.fr Supplementary information: Supplementary data are available at Bioinformatics online. PMID:22923296

  19. Evaluation of polyethylene glycol coated liposomes labeled with Tc-99m as a blood pool agent

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Phillips, W.T.; Klipper, R.; Goins, B.

    1994-05-01

    This investigation evaluated Tc-99m liposomes coated with polyethylene glycol (PEG) as a blood pool agent in comparison with Tc-99m liposomes carrying no surface charge (Neutral) and with Tc-99m autologous red cells. Liposomes (135 nm diameter) encapsulating glutathione were labeled with Tc-99m using the lipophilic chelator, HMPAO as previously described. Autologous red cells were labeled using an Ultratag kit. Labeling efficiencies averaged 66%, 52%, and 97% for the PEG liposomes. Neutral liposomes, and red cells, respectively. Rabbits (3-3.5 Kg) were injected IV via ear vein with 2.0 mls of PEG liposomes (2 mCi, 17 mg phospholipid/Kg body weight, n=5). Neutral liposomesmore » (1.3 mCi, 17 mg phospholipid/Kg body weight, n=4), or red cells (2.6 mCi, n=2). Gamma camera images were acquired at 5,22, and 45 minutes, and 2,20,and 44 hours post-injection. Blood samples were obtained at each time point to determine clearance kinetics. Circulation half lives of both Tc-99m liposome formulations were longer than Tc-99m red cells (8 hrs), with the half life of PEG liposomes (35 hrs) 1.6 times longer than Neutral liposomes (22 hrs). In vivo stability of the Tc-99m label was excellent for the liposomes with only 3.5-4% bladder activity at 45 minutes compared to 12% bladder activity for the red cells. Excellent blood pool images were obtained for the PEG liposomes in the rabbit. Heart/liver ratios calculated from region of interest analysis of 45 minutes images were 1.9, 1.5, and 1.7 for PEG liposomes, Neutral liposomes and red cells. This study demonstrates the feasibility of using Tc-99m PEG liposomes to perform gated cardiac blood pool and rapid gastrointestinal bleeding studies.« less

  20. A Tc-99m-labeled long chain fatty acid derivative for myocardial imaging.

    PubMed

    Magata, Yasuhiro; Kawaguchi, Takayoshi; Ukon, Misa; Yamamura, Norio; Uehara, Tomoya; Ogawa, Kazuma; Arano, Yasushi; Temma, Takashi; Mukai, Takahiro; Tadamura, Eiji; Saji, Hideo

    2004-01-01

    C-11- and I-123-labeled long chain fatty acid derivatives have been reported as useful radiopharmaceuticals for the estimation of myocardial fatty acid metabolism. We have reported that Tc-99m-labeled N-[[[(2-mercaptoethyl)amino]carbonyl]methyl]-N-(2-mercaptoethyl)-6-aminohexanoic acid ([(99m)Tc]MAMA-HA), a medium chain fatty acid derivative, is metabolized by beta-oxidation in the liver and that the MAMA ligand is useful for attaching to the omega-position of fatty acid derivatives as a chelating group for Tc-99m. On the basis of these findings, we focused on developing a Tc-99m-labeled long chain fatty acid derivative that reflected fatty acid metabolism in the myocardium. In this study, we synthesized a dodecanoic acid derivative, MAMA-DA, and a hexadecanoic acid derivative, MAMA-HDA, and performed radiolabeling and biodistribution studies. [(99m)Tc]MAMA-DA and [(99m)Tc]MAMA-HDA were prepared using a ligand-exchange reaction. Biodistribution studies were carried out in normal mice and rats. Then, a high initial uptake of Tc-99m was observed, followed by a rapid clearance from the heart. The maximum heart/blood ratio was 3.6 at 2 min postinjection of [(99m)Tc]MAMA-HDA. These kinetics were similar to those with postinjection of p-[(125)I]iodophenylpentadecanoic acid. Metabolite analysis showed [(99m)Tc]MAMA-HDA was metabolized by beta-oxidation in the body. In conclusion, [(99m)Tc]MAMA-HDA is a promising compound as a long chain fatty acid analogue for estimating beta-oxidation of fatty acid in the heart.

  1. Comparison of 99mTc-HYNIC-TOC and HYNIC-TATE octreotide scintigraphy with FDG PET and 99mTc-MIBI in local recurrent or distant metastatic thyroid cancers.

    PubMed

    Sager, Sait; Kabasakal, Levent; Halac, Metin; Maecke, Helmut; Uslu, Lebriz; Önsel, Çetin; Kanmaz, Bedii

    2013-05-01

    There have been various studies for early diagnosis of local recurrent or distant metastatic thyroid cancers. The aim of this study is to evaluate the clinical utility of 99mTc-HYNIC-TOC and 99mTc-HYNIC-TATE, octreotide derivatives, to detect recurrences or distant metastases in 131I-negative thyroglobulin positive thyroid cancer patients and to compare the lesions with FDG PET and 99mTc-MIBI studies in the same patient group. Twenty differentiated thyroid cancer patients, 7 male and 13 female, mean age 54.6 ± 15.3 (range 13-78 years), were included in this study. Eighteen patients had papillary thyroid cancer and 2 had follicular thyroid cancer. Fifteen patients received HYNIC-TOC and 5 patients received HYNIC-TATE as a radiopharmaceutical. All patients underwent whole-body scan 1 and 4 hours after injection of octreotide derivatives and SPECT imagings were performed from the suspicious sites. The lesions that were seen in 99mTc-HYNIC-TOC and 99mTc-HYNIC-TATE studies were compared with 99mTc-MIBI and FDG-PET studies. Among 99mTc-HYNIC-TOC and 99mTc-HYNIC-TATE scintigraphies, 15 patient studies were evaluated as true positive (75%) and 5 were false negative (25%). The total number of lesions in octreotide scintigraphy was 48 in 20 patients. Of 20 patients, 19 had FDG-PET study, 15 of them were evaluated as true positive (78.9%), and 4 them were evaluated as false negative (21.1%). Total number of lesions in FDG PET was 74. 99mTc-MIBI study was positive in 11 patients (55%) and negative in 9 patients (45%). Total number of lesions in 99mTc-MIBI was 25. Technetium-labeled somatostatin receptor scintigraphy analogues HYNIC-TOC and HYNIC-TATE are useful imaging alternatives in somatostatin receptor expressing thyroid cancer patients. Radiolabeling is easy and they are readily available for routine use.

  2. 75 FR 3253 - Lamb Assembly and Test, LLC, Subsidiary of Mag Industrial Automation Systems, Machesney Park, IL...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-20

    ..., LLC, Subsidiary of Mag Industrial Automation Systems, Machesney Park, IL; Notice of Negative... automation equipment and machine tools did not contribute to worker separations at the subject facility and...' firm's declining customers. The survey revealed no imports of automation equipment and machine tools by...

  3. Isothiocyanate-Functionalized Bifunctional Chelates and fac-[M(I)(CO)3](+) (M = Re, (99m)Tc) Complexes for Targeting uPAR in Prostate Cancer.

    PubMed

    Kasten, Benjamin B; Ma, Xiaowei; Cheng, Kai; Bu, Lihong; Slocumb, Winston S; Hayes, Thomas R; Trabue, Steven; Cheng, Zhen; Benny, Paul D

    2016-01-20

    Developing new strategies to rapidly incorporate the fac-[M(I)(CO)3](+) (M = Re, (99m)Tc) core into biological targeting vectors in radiopharmaceuticals continues to expand as molecules become more complex and as efforts to minimize nonspecific binding increase. This work examines a novel isothiocyanate-functionalized bifunctional chelate based on 2,2'-dipicolylamine (DPA) specifically designed for complexing the fac-[M(I)(CO)3](+) core. Two strategies (postlabeling and prelabeling) were explored using the isothiocyanate-functionalized DPA to determine the effectiveness of assembly on the overall yield and purity of the complex with amine containing biomolecules. A model amino acid (lysine) examined (1) amine conjugation of isothiocyanate-functionalized DPA followed by complexation with fac-[M(I)(CO)3](+) (postlabeling) and (2) complexation of fac-[M(I)(CO)3](+) with isothiocyanate-functionalized DPA followed by amine conjugation (prelabeling). Conducted with stable Re and radioactive (99m)Tc analogs, both strategies formed the product in good to excellent yields under macroscopic and radiotracer concentrations. A synthetic peptide (AE105) which targets an emerging biomarker in CaP prognosis, urokinase-type plasminogen activator receptor (uPAR), was also explored using the isothiocyanate-functionalized DPA strategy. In vitro PC-3 (uPAR+) cell uptake assays with the (99m)Tc-labeled peptide (8a) showed 4.2 ± 0.5% uptake at 4 h. In a murine model bearing PC-3 tumor xenografts, in vivo biodistribution of 8a led to favorable tumor uptake (3.7 ± 0.7% ID/g) at 4 h p.i. with relatively low accumulation (<2% ID/g) in normal organs not associated with normal peptide excretion. These results illustrate the promise of the isothiocyanate-functionalized approach for labeling amine containing biological targeting vectors with fac-[M(I)(CO)3](+).

  4. Evaluation of hepatic function with (99m)Tc-galactosylated serum albumin scintigraphy in patients with malaria: comparison with (99m)Tc-colloid scintigraphy and liver ultrasonography.

    PubMed

    Lee, Sang-Woo; Lee, Jaetae; Lee, Deog-Young; Chun, Kyung-Ah; Ahn, Byeong-Cheol; Kang, Young-Mo; Lee, Kyubo

    2007-02-01

    Malarial parasites injected by the mosquito rapidly target hepatocytes, and hepatomegaly is commonly observed during the progress of the disease in malaria patients. To evaluate the degree of hepatic damage and functional status of hepatocytes in malaria patients, we performed liver scintigraphy using (99m)Tc-galactosylated serum albumin (GSA) prospectively and the findings were compared with those of (99m)Tc-colloid scintigraphy, ultrasonography and clinical results in the same subject. Eight malaria patients (all male, mean age 22 years) confirmed to be infected with Plasmodium vivax underwent (99m)Tc-GSA liver scintigraphy, followed by liver ultrasonography and (99m)Tc-colloid scintigraphy using phytate within 3 days. For hepatocyte scintigraphy, anterior images of cardiac blood-pool and liver were continuously acquired for 30 min after injection of 185 MBq (99m)Tc-GSA (3 mg). In addition to visual interpretation of the images, quantitative measurement of hepatic function was performed with several functional parameters, such as hepatic uptake index (LHL15), blood clearance index (HH15) and modified receptor index (LHL/HH) calculated from the radioactivity of the liver and heart. (99m)Tc-colloid images were assessed and graded visually. Severity of hepatic dysfunction or reticuloendothelial system activation was classified as normal, mild, moderate and severe on GSA or colloid images. Hepatomegaly was observed in five and splenomegaly in seven of the eight patients. Serum levels of transaminase and alkaline phosphatase were mildly elevated in two. Visual assessment of GSA scintigraphy revealed normal findings in all subjects, except for mild increases in size. The mean values of LHL15, HH15 and LHL/HH were 0.928+/-0.014, 0.537+/-0.031 and 1.732+/-0.106, respectively. They were graded as normal in five, and near-normal to mild dysfunction in three subjects. In contrast, (99m)Tc-colloid scintigraphy revealed abnormal findings in all of the subjects, and graded as

  5. The Local Dinucleotide Preference of APOBEC3G Can Be Altered from 5′-CC to 5′-TC by a Single Amino Acid Substitution

    PubMed Central

    Rathore, Anurag; Carpenter, Michael A; Demir, Özlem; Ikeda, Terumasa; Li, Ming; Shaban, Nadine; Law, Emily K.; Anokhin, Dmitry; Brown, William L.; Amaro, Rommie E.; Harris, Reuben S.

    2013-01-01

    APOBEC3A and APOBEC3G are DNA cytosine deaminases with biological functions in foreign DNA and retrovirus restriction, respectively. APOBEC3A has an intrinsic preference for cytosine preceded by thymine (5′-TC) in single-stranded DNA substrates, whereas APOBEC3G prefers the target cytosine to be preceded by another cytosine (5′-CC). To determine the amino acids responsible for these strong dinucleotide preferences, we analyzed a series of chimeras in which putative DNA binding loop regions of APOBEC3G were replaced with the corresponding regions from APOBEC3A. Loop 3 replacement enhanced APOBEC3G catalytic activity but did not alter its intrinsic 5′-CC dinucleotide substrate preference. Loop 7 replacement caused APOBEC3G to become APOBEC3A-like and strongly prefer 5′-TC substrates. Simultaneous loop 3/7 replacement resulted in a hyperactive APOBEC3G variant that also preferred 5′-TC dinucleotides. Single amino acid exchanges revealed D317 as a critical determinant of dinucleotide substrate specificity. Multi-copy explicitly solvated all-atom molecular dynamics simulations suggested a model in which D317 acts as a helix-capping residue by constraining the mobility of loop 7, forming a novel binding pocket that favorably accommodates cytosine. All catalytically active APOBEC3G variants, regardless of dinucleotide preference, retained HIV-1 restriction activity. These data support a model in which the loop 7 region governs the selection of local dinucleotide substrates for deamination but is unlikely to be part of the higher level targeting mechanisms that direct these enzymes to biological substrates such as HIV-1 cDNA. PMID:23938202

  6. Low-activity 124I-PET/low-dose CT versus 99mTc-pertechnetate planar scintigraphy or 99mTc-pertechnetate single-photon emission computed tomography of the thyroid: a pilot comparison.

    PubMed

    Darr, Andreas M; Opfermann, Thomas; Niksch, Tobias; Driesch, Dominik; Marlowe, Robert J; Freesmeyer, Martin

    2013-10-01

    The standard thyroid functional imaging method, 99mTc-pertechnetate (99mTc-PT) planar scintigraphy, has technical drawbacks decreasing its sensitivity in detecting nodules or anatomical pathology. 124I-PET, lacking these disadvantages and allowing simultaneous CT, may have greater sensitivity for these purposes. We performed a blinded pilot comparison of 124I-PET(/CT) versus 99mTc-PT planar scintigraphy or its cross-sectional enhancement, 99mTc-PT single-photon emission CT (SPECT), in characterizing the thyroid gland with benign disease. Twenty-one consecutive adults with goiter underwent low-activity (1 MBq/0.027 mCi) 124I-PET/low-dose (30 mAs) CT, 99mTc-PT planar scintigraphy, and 99mTc-PT-SPECT. Endpoints included the numbers of “hot spots” with/without central photopenia and “cold spots” detected, the proportion of these lesions with morphological correlates, the mean volume and diameter of visualized nodules, and the number of cases of lobus pyramidalis or retrosternal thyroid tissue identified. 124I-PET detected significantly more “hot spots” with/without central photopenia (P < 0.001), significantly more nodules (P < 0.001), and more “cold spots” than did 99mTc-PT planar scintigraphy or 99mTc-PT-SPECT, including all lesions seen on the 99mTc-PT modalities. Ultrasonographic correlates were found for all nodules visualized on all 3 modalities and 92.5% of nodules seen only on 124I-PET. Nodules discernible only on 124I-PET had significantly smaller mean volume or diameter (P < 0.001) than did those visualized on 99mTc-PT planar scintigraphy or 99mTc-PT-SPECT. 124I-PET(/CT) identified significantly more patients with a lobus pyramidalis (P < 0.001) or retrosternal thyroid tissue (P < 0.05). 124I-PET(/CT) may provide superior imaging of benign thyroid disease compared to planar or cross-sectional 99mTc-PT scintigraphy.

  7. The Tribolium chitin synthase genes TcCHS1 and TcCHS2 are specialized for synthesis of epidermal cuticle and midgut peritrophic matrix.

    PubMed

    Arakane, Y; Muthukrishnan, S; Kramer, K J; Specht, C A; Tomoyasu, Y; Lorenzen, M D; Kanost, M; Beeman, R W

    2005-10-01

    Functional analysis of the two chitin synthase genes, TcCHS1 and TcCHS2, in the red flour beetle, Tribolium castaneum, revealed unique and complementary roles for each gene. TcCHS1-specific RNA interference (RNAi) disrupted all three types of moult (larval-larval, larval-pupal and pupal-adult) and greatly reduced whole-body chitin content. Exon-specific RNAi showed that splice variant 8a of TcCHS1 was required for both the larval-pupal and pupal-adult moults, whereas splice variant 8b was required only for the latter. TcCHS2-specific RNAi had no effect on metamorphosis or on total body chitin content. However, RNAi-mediated down-regulation of TcCHS2, but not TcCHS1, led to cessation of feeding, a dramatic shrinkage in larval size and reduced chitin content in the midgut.

  8. Transient Expression of CRISPR/Cas9 Machinery Targeting TcNPR3 Enhances Defense Response in Theobroma cacao.

    PubMed

    Fister, Andrew S; Landherr, Lena; Maximova, Siela N; Guiltinan, Mark J

    2018-01-01

    Theobroma cacao , the source of cocoa, suffers significant losses to a variety of pathogens resulting in reduced incomes for millions of farmers in developing countries. Development of disease resistant cacao varieties is an essential strategy to combat this threat, but is limited by sources of genetic resistance and the slow generation time of this tropical tree crop. In this study, we present the first application of genome editing technology in cacao, using Agrobacterium-mediated transient transformation to introduce CRISPR/Cas9 components into cacao leaves and cotyledon cells. As a first proof of concept, we targeted the cacao Non-Expressor of Pathogenesis-Related 3 (TcNPR3) gene, a suppressor of the defense response. After demonstrating activity of designed single-guide RNAs (sgRNA) in vitro , we used Agrobacterium to introduce a CRISPR/Cas9 system into leaf tissue, and identified the presence of deletions in 27% of TcNPR3 copies in the treated tissues. The edited tissue exhibited an increased resistance to infection with the cacao pathogen Phytophthora tropicalis and elevated expression of downstream defense genes. Analysis of off-target mutagenesis in sequences similar to sgRNA target sites using high-throughput sequencing did not reveal mutations above background sequencing error rates. These results confirm the function of NPR3 as a repressor of the cacao immune system and demonstrate the application of CRISPR/Cas9 as a powerful functional genomics tool for cacao. Several stably transformed and genome edited somatic embryos were obtained via Agrobacterium -mediated transformation, and ongoing work will test the effectiveness of this approach at a whole plant level.

  9. Transient Expression of CRISPR/Cas9 Machinery Targeting TcNPR3 Enhances Defense Response in Theobroma cacao

    PubMed Central

    Fister, Andrew S.; Landherr, Lena; Maximova, Siela N.; Guiltinan, Mark J.

    2018-01-01

    Theobroma cacao, the source of cocoa, suffers significant losses to a variety of pathogens resulting in reduced incomes for millions of farmers in developing countries. Development of disease resistant cacao varieties is an essential strategy to combat this threat, but is limited by sources of genetic resistance and the slow generation time of this tropical tree crop. In this study, we present the first application of genome editing technology in cacao, using Agrobacterium-mediated transient transformation to introduce CRISPR/Cas9 components into cacao leaves and cotyledon cells. As a first proof of concept, we targeted the cacao Non-Expressor of Pathogenesis-Related 3 (TcNPR3) gene, a suppressor of the defense response. After demonstrating activity of designed single-guide RNAs (sgRNA) in vitro, we used Agrobacterium to introduce a CRISPR/Cas9 system into leaf tissue, and identified the presence of deletions in 27% of TcNPR3 copies in the treated tissues. The edited tissue exhibited an increased resistance to infection with the cacao pathogen Phytophthora tropicalis and elevated expression of downstream defense genes. Analysis of off-target mutagenesis in sequences similar to sgRNA target sites using high-throughput sequencing did not reveal mutations above background sequencing error rates. These results confirm the function of NPR3 as a repressor of the cacao immune system and demonstrate the application of CRISPR/Cas9 as a powerful functional genomics tool for cacao. Several stably transformed and genome edited somatic embryos were obtained via Agrobacterium-mediated transformation, and ongoing work will test the effectiveness of this approach at a whole plant level. PMID:29552023

  10. The inducible costimulator augments Tc17 cell responses to self and tumor tissue

    PubMed Central

    Nelson, Michelle H.; Kundimi, Sreenath; Bowers, Jacob S.; Rogers, Carolyn E.; Huff, Logan W.; Schwartz, Kristina M.; Thyagarajan, Krishnamurthy; Little, Elizabeth C.; Mehrotra, Shikhar; Cole, David J.; Rubinstein, Mark P.; Paulos, Chrystal M.

    2014-01-01

    The inducible costimulator (ICOS) plays a key role in CD4+ Th17 cell development, but its role in CD8+ Tc17 cell development and self/tumor immunity remains unknown. We found that ICOS co-stimulation was important for the functional maintenance but not differentiation of Tc17 cells in vitro. Blocking the ICOS pathway using an antagonist antibody or by using mice genetically deficient in the ICOS ligand (ICOSL) reduced the antitumor activity of adoptively transferred Tc17 cells. Conversely, activating Tc17 cells with an ICOS agonist in vitro enhanced their capacity to eradicate melanoma and induce autoimmune vitiligo when infused into mice. However, ICOS stimulation did not augment the antitumor activity of IL-2 expanded T cells. Additional investigation revealed that ICOS stimulation not only increased IL-2Rα, CXCR3 and IL-23R expression on Tc17 cells, but also dampened their expression of suppressive molecule CD39. Although Tc17 cells activated with an ICOS agonist co-secreted heightened IL-17A, IL-9 and IFN-γ, their therapeutic effectiveness was critically dependent on IFN-γ production. Depletion of IL-17A and IL-9 had little impact of antitumor Tc17 cells activated with an ICOS agonist. Collectively, our work reveals that the ICOS pathway potentiates the antitumor activity of adoptively transferred Tc17 cells. This work has major implications for the design of vaccine, antibody and cell-based therapies for autoimmunity, infectious disease and cancer. PMID:25576595

  11. Assessment of the direct cyclotron production of (99m)Tc: An approach to crisis management of (99m)Tc shortage.

    PubMed

    Rovais, Mohammad Reza Aboudzadeh; Aardaneh, Khosro; Aslani, Gholamreza; Rahiminejad, Ali; Yousefi, Kamran; Boulouri, Fatemeh

    2016-06-01

    Nowadays, the cyclotron production of technetium-99m ((99m)Tc) has been increased, due to the worldwide (99m)Tc generator shortage. In the present work, an improved strategy for the production of (99m)Tc, using the proton irradiation of the enriched (100)Mo was developed. The performance of this method in terms of the production yield, chemical purity, radiochemical purity, as well as radionuclide purity was evaluated. The average production yield was measured to be 356MBqμA(-1)h(-1). A good agreement was found between the calculated production yield and the experimental one. The radiochemical separation and total recovery yields of (99m)Tc were 92% and 69%, respectively. The radiochemical and the radionuclide purities of the (99m)Tc were 99% and >99.99% at the end of purification, respectively. The results of quality control tests (QC) support the concept that cyclotron-produced (99m)Tc is suitable for preparation of USP-compliant. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. [Comparative study of the biodistribution of (99m)Tc-HYNIC-Lys3-Bombesin obtained with the EDDA/tricine and NA/tricine as coligands].

    PubMed

    Hernández-Cairo, A; Perera-Pintado, A; Prats-Capote, A; Batista-Cuellar, J F; Casacó-Santana, C

    2012-01-01

    The aim of present investigation was to evaluate biodistribution in healthy animals and in tumor models of the radiopharmaceuticals (99m)Tc-EDDA/tricine-HYNIC-Lys3-Bombesin (HYNIC-Lys3-BN) and (99m)Tc-NA/tricine-HYNIC-Lys3-BN. Biodistribution and pharmacokinetics were carried out over 24 hours. To do so, 24 healthy Wistar rats were used and were administered 37.0 ± 0.8 MBq/rat of each radiopharmaceutical. For the tumor model study, 20 CD-1 nude mice were used and prostate tumors (PC3) were implanted in all the mice. Ten days later, tumor volumes were calculated and 40.00 ± 0.04 MBq/mice of each radiopharmaceutical were injected. Both showed high radiochemical purity: 98.08 ± 0.25% for EDDA/tricine product and 95.1 ± 0.3% for the conjugate with NA/tricine. Uptake of the radiopharmaceutical with NA/tricine was significantly higher in organs of the reticulo-endothelial system of healthy Wistar rats during 24h, specifically in the liver and spleen. Both labeled compounds showed no significant differences between their blood elimination half lives. Average of tumor growth was 0.93 ± 0.02 cm(3) and affinity for tumors showed a growing and specific binding of both radiopharmaceuticals, although it was significantly higher for the EDDA/tricine conjugate. This outcome made it possible to corroborate the direct relationship between the density of gastrin releasing peptide and its receptors (GRPr) and the variation of the accumulation of the radiopharmaceuticals in the tumor. Use of EDDA/tricine as coligand is more appropriate than NA/tricine for labeling of HYNIC-Lys3-BN with (99m)Tc. Copyright © 2011 Elsevier España, S.L. y SEMNIM. All rights reserved.

  13. An increase in Tc under hydrostatic pressure in the superconducting doped topological insulator Nb0.25Bi2Se3

    NASA Astrophysics Data System (ADS)

    Smylie, M. P.; Willa, K.; Ryan, K.; Claus, H.; Kwok, W.-K.; Qiu, Y.; Hor, Y. S.; Welp, U.

    2017-12-01

    We report a positive hydrostatic pressure derivative of the superconducting transition temperature in the doped topological insulator Nb0.25Bi2Se3 via dc SQUID magnetometry in pressures up to 0.6 GPa. This result is contrary to reports on the homologues CuxBi2Se3 and SrxBi2Se3 where smooth suppression of Tc is observed. This difference may be attributable to an electronic structure composed of multiple bands whereas the other materials in the superconducting doped Bi2Se3 family are believed to be single-band.

  14. Isothiocyanate-functionalized bifunctional chelates and fac-[MI(CO)3]+ (M = Re, 99mTc) complexes for targeting uPAR in prostate cancer

    USDA-ARS?s Scientific Manuscript database

    Developing strategies to rapidly incorporate the fac-[MI(CO)3]+ (M = Re, 99mTc) core into biological targeting vectors is a growing realm in radiopharmaceutical development. This work presents the preparation of a novel isothiocyanate-functionalized bifunctional chelate based on 2,2´-dipicolylamine ...

  15. Discordant hepatic uptake between Tc-99m sulfur colloid and Tc-99m DISIDA in hypervitaminosis A

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vincent, L.M.; McCartney, W.H.; Mauro, M.A.

    1984-02-01

    Scintigraphic findings in a patient with biopsy-proven hypervitaminosis A included markedly impaired hepatic uptake of Tc-99m sulfur colloid but essentially normal uptake of Tc-99m DISIDA. This case presents a potential cause for image discordance with these two agents.

  16. Synthesis, Characterization, and Preclinical Evaluation of (99m)Tc-Labeled Macrobicyclic and Tricyclic Chelators as Single Photon Emission Computed Tomography Tracer.

    PubMed

    Yadav, Neelam; Chuttani, Krishna; Mishra, Anil K; Singh, Bachcha

    2016-05-01

    The novel tetraaza macrobicyclic chelator 3,6,9,15-tetraazabicyclo[9.3.1]pentadeca-1(15),11,13-triene-2,10-dione (TBPD) and pentaaza macrotricyclic chelator 9-oxa-3,6,12,15,21-pentaazatricyclo[15,3,2,1]trieicos-1(21),17,19-triene-2,7,11,16-tetradione (OPTT) were synthesized, characterized, and radiolabeled with (99m)Tc to produce (99m)Tc-TBPD and (99m)Tc-OPTT. These radiolabeled complexes were prepared with high radiolabeling yield, radiochemical purity, and good in vitro stability up to 24 h. The labeling efficiency of (99m)Tc-TBPD and (99m)Tc-OPTT was found 98% and 97%. In vitro serum stability of (99m)Tc-TBPD was found to be 95.2%, while that of (99m)Tc-OPTT 94.2% up to 24 h. Blood kinetics experiments of (99m)Tc-labeled complexes showed biphasic pattern of blood clearance. About 99.57 ± 0.89% activity of (99m)Tc-TBPD and 99.42 ± 0.88% activity of (9m)Tc-OPTT were cleared off blood stream at 24 h postadministration. The biological half-life of (99m) Tc-TBPD was observed: t1/2(F) 1 h 5 min and t1/2(S) 12 h and biological half-life of (99m)Tc-OPTT was observed: t1/2(F) 1 h 10 min and t1/2(S) 9 h 50 min, respectively. The biodistribution studies revealed that maximum uptake of (99m)Tc-TBPD was found in liver, concluded that excretory pathway is hepatobiliary, while that of (99m)Tc-OPTT was renal as well as hepatobiliary. The negligible activity observed in stomach confirming the stability of radiolabeled complex in biological milieu. In vitro cytotoxicity study of TBPD and OPTT did not show any considerable antiproliferative activity against cancer cells of human cervical SW756, HeLa, and glioblastoma U-87, U373 cell lines. © 2015 John Wiley & Sons A/S.

  17. Diuretic renography in hydronephrosis: renal tissue tracer transit predicts functional course and thereby need for surgery.

    PubMed

    Schlotmann, Andreas; Clorius, John H; Clorius, Sandra N

    2009-10-01

    The recognition of those hydronephrotic kidneys which require therapy to preserve renal function remains difficult. We retrospectively compared the 'tissue tracer transit' (TTT) of (99m)Tc-mercaptoacetyltriglycine ((99m)Tc-MAG(3)) with 'response to furosemide stimulation' (RFS) and with 'single kidney function < 40%' (SKF < 40%) to predict functional course and thereby need for surgery. Fifty patients with suspected unilateral obstruction and normal contralateral kidney had 115 paired (baseline/follow-up) (99m)Tc-MAG(3) scintirenographies. Three predictions of the functional development were derived from each baseline examination: the first based on TTT (visually assessed), the second on RFS and the third on SKF < 40%. Each prediction also considered whether the patient had surgery. Possible predictions were 'better', 'worse' or 'stable' function. A comparison of SKF at baseline and follow-up verified the predictions. The frequency of correct predictions for functional improvement following surgery was 8 of 10 kidneys with delayed TTT, 9 of 22 kidneys with obstructive RFS and 9 of 21 kidneys with SKF < 40%; for functional deterioration without surgery it was 2 of 3 kidneys with delayed TTT, 3 of 20 kidneys with obstructive RFS and 3 of 23 kidneys with SKF < 40%. Without surgery 67 of 70 kidneys with timely TTT maintained function. Without surgery 0 of 9 kidneys with timely TTT but obstructive RFS and only 1 of 16 kidneys with timely TTT but SKF < 40% lost function. Delayed TTT appears to identify the need for therapy to preserve function of hydronephrotic kidneys, while timely TTT may exclude risk even in the presence of an obstructive RFS or SKF < 40%.

  18. Immune Protection against Trypanosoma cruzi Induced by TcVac4 in a Canine Model

    PubMed Central

    Aparicio-Burgos, José E.; Zepeda-Escobar, José A.; de Oca-Jimenez, Roberto Montes; Estrada-Franco, José G.; Barbabosa-Pliego, Alberto; Ochoa-García, Laucel; Alejandre-Aguilar, Ricardo; Rivas, Nancy; Peñuelas-Rivas, Giovanna; Val-Arreola, Margarita; Gupta, Shivali; Salazar-García, Felix; Garg, Nisha J.; Vázquez-Chagoyán, Juan C.

    2015-01-01

    Chagas disease, caused by Trypanosoma cruzi, is endemic in southern parts of the American continent. Herein, we have tested the protective efficacy of a DNA-prime/T. rangeli-boost (TcVac4) vaccine in a dog (Canis familiaris) model. Dogs were immunized with two-doses of DNA vaccine (pcDNA3.1 encoding TcG1, TcG2, and TcG4 antigens plus IL-12- and GM-CSF-encoding plasmids) followed by two doses of glutaraldehyde-inactivated T. rangeli epimastigotes (TrIE); and challenged with highly pathogenic T. cruzi (SylvioX10/4) isolate. Dogs given TrIE or empty pcDNA3.1 were used as controls. We monitored post-vaccination and post-challenge infection antibody response by an ELISA, parasitemia by blood analysis and xenodiagnosis, and heart function by electrocardiography. Post-mortem anatomic and pathologic evaluation of the heart was conducted. TcVac4 induced a strong IgG response (IgG2>IgG1) that was significantly expanded post-infection, and moved to a nearly balanced IgG2/IgG1 response in chronic phase. In comparison, dogs given TrIE or empty plasmid DNA only developed high IgG titers with IgG2 predominance in response to T. cruzi infection. Blood parasitemia, tissue parasite foci, parasite transmission to triatomines, electrocardiographic abnormalities were significantly lower in TcVac4-vaccinated dogs than was observed in dogs given TrIE or empty plasmid DNA only. Macroscopic and microscopic alterations, the hallmarks of chronic Chagas disease, were significantly decreased in the myocardium of TcVac4-vaccinated dogs. We conclude that TcVac4 induced immunity was beneficial in providing resistance to T. cruzi infection, evidenced by control of chronic pathology of the heart and preservation of cardiac function in dogs. Additionally, TcVac4 vaccination decreased the transmission of parasites from vaccinated/infected animals to triatomines. PMID:25853654

  19. Immune protection against Trypanosoma cruzi induced by TcVac4 in a canine model.

    PubMed

    Aparicio-Burgos, José E; Zepeda-Escobar, José A; de Oca-Jimenez, Roberto Montes; Estrada-Franco, José G; Barbabosa-Pliego, Alberto; Ochoa-García, Laucel; Alejandre-Aguilar, Ricardo; Rivas, Nancy; Peñuelas-Rivas, Giovanna; Val-Arreola, Margarita; Gupta, Shivali; Salazar-García, Felix; Garg, Nisha J; Vázquez-Chagoyán, Juan C

    2015-04-01

    Chagas disease, caused by Trypanosoma cruzi, is endemic in southern parts of the American continent. Herein, we have tested the protective efficacy of a DNA-prime/T. rangeli-boost (TcVac4) vaccine in a dog (Canis familiaris) model. Dogs were immunized with two-doses of DNA vaccine (pcDNA3.1 encoding TcG1, TcG2, and TcG4 antigens plus IL-12- and GM-CSF-encoding plasmids) followed by two doses of glutaraldehyde-inactivated T. rangeli epimastigotes (TrIE); and challenged with highly pathogenic T. cruzi (SylvioX10/4) isolate. Dogs given TrIE or empty pcDNA3.1 were used as controls. We monitored post-vaccination and post-challenge infection antibody response by an ELISA, parasitemia by blood analysis and xenodiagnosis, and heart function by electrocardiography. Post-mortem anatomic and pathologic evaluation of the heart was conducted. TcVac4 induced a strong IgG response (IgG2>IgG1) that was significantly expanded post-infection, and moved to a nearly balanced IgG2/IgG1 response in chronic phase. In comparison, dogs given TrIE or empty plasmid DNA only developed high IgG titers with IgG2 predominance in response to T. cruzi infection. Blood parasitemia, tissue parasite foci, parasite transmission to triatomines, electrocardiographic abnormalities were significantly lower in TcVac4-vaccinated dogs than was observed in dogs given TrIE or empty plasmid DNA only. Macroscopic and microscopic alterations, the hallmarks of chronic Chagas disease, were significantly decreased in the myocardium of TcVac4-vaccinated dogs. We conclude that TcVac4 induced immunity was beneficial in providing resistance to T. cruzi infection, evidenced by control of chronic pathology of the heart and preservation of cardiac function in dogs. Additionally, TcVac4 vaccination decreased the transmission of parasites from vaccinated/infected animals to triatomines.

  20. Impeding 99Tc(IV) mobility in novel waste forms

    PubMed Central

    Lee, Mal-Soon; Um, Wooyong; Wang, Guohui; Kruger, Albert A.; Lukens, Wayne W.; Rousseau, Roger; Glezakou, Vassiliki-Alexandra

    2016-01-01

    Technetium (99Tc) is an abundant, long-lived radioactive fission product whose mobility in the subsurface is largely governed by its oxidation state. Tc immobilization is crucial for radioactive waste management and environmental remediation. Tc(IV) incorporation in spinels has been proposed as a novel method to increase Tc retention in glass waste forms during vitrification. However, experiments under high-temperature and oxic conditions show reoxidation of Tc(IV) to volatile pertechnetate, Tc(VII). Here we examine this problem with ab initio molecular dynamics simulations and propose that, at elevated temperatures, doping with first row transition metal can significantly enhance Tc retention in magnetite in the order Co>Zn>Ni. Experiments with doped spinels at 700 °C provide quantitative confirmation of the theoretical predictions in the same order. This work highlights the power of modern, state-of-the-art simulations to provide essential insights and generate theory-inspired design criteria of complex materials at elevated temperatures. PMID:27357121

  1. Diagnostic accuracy of [99mTc]Tc-Sestamibi in the assessment of thyroid nodules.

    PubMed

    Yordanova, Anna; Mahjoob, Soha; Lingohr, Philipp; Kalff, Jörg; Türler, Andreas; Palmedo, Holger; Biersack, Hans-Jürgen; Kristiansen, Glen; Farahati, Jamshid; Essler, Markus; Ahmadzadehfar, Hojjat

    2017-11-07

    [ 99m Tc]Tc-Sestamibi (MIBI) is an increasingly used tool for evaluation of thyroid nodules. However, there is a lack of evidence about the accuracy of this method in the European population. The aim of this study was to assess the utility of MIBI for the differentiation of thyroid nodules in a large cohort. 161 patients underwent MIBI, followed by a thyroidectomy. We used a dual phase MIBI protocol. Interpretation of the images included a scoring system from 0 (absent) to 3 (increased); this was to provide a scale for the uptake of the thyroid nodule in comparison to the paranodular tissue. Additionally, we evaluated the tracer uptake trend in late images compared to early images. We used the final histopathology as the reference standard. Scores 0-1 in early images, scores 0-2 in late images, and an absence of increasing uptake in the thyroid nodule in late images, showed the best predictive values to exclude malignancy, respectively (negative predictive value (NPV) 89%). Highest sensitivity (91%) for malignant nodules was evident in early images with a score 1-3. Highest specificity (91%) was obtained when the negative was defined as an absence of uptake-increase, in the late images. This study confirms that the most valuable feature of MIBI is the high NPV. Thus, with the appropriate interpretation method, high sensitivity and specificity, and moderate PPV can be obtained.

  2. Preparation of epitaxial TlBa2Ca2Cu3O9 high Tc thin films on LaAlO3 (100) substrates

    NASA Astrophysics Data System (ADS)

    Piehler, A.; Reschauer, N.; Spreitzer, U.; Ströbel, J. P.; Schönberger, R.; Renk, K. F.; Saemann-Ischenko, G.

    1994-09-01

    Epitaxial TlBa2Ca2Cu3O9 high Tc thin films were prepared on LaAlO3 (100) substrates by a combination of laser ablation and thermal evaporation of thallium oxide. X-ray diffraction patterns of θ-2θ scans showed that the films consisted of highly c axis oriented TlBa2Ca2Cu3O9. φ scan measurements revealed an epitaxial growth of the TlBa2Ca2Cu3O9 thin films on the LaAlO3 (100) substrates. Ac inductive measurements indicated the onset of superconductivity at 110 K. At 6 K, the critical current density was 4×106 A/cm2 in zero magnetic field and 6×105 A/cm2 at a magnetic field of 3 T parallel to the c axis.

  3. Microstructural characterization and tribological behavior of surface plasma Zr-Er alloying on TC11 alloy

    NASA Astrophysics Data System (ADS)

    Wei, Dongbo; Zhang, Pingze; Liu, Yingchao; Chen, Xiaohu; Ding, Feng; Li, Fengkun

    2018-02-01

    The Zr coating and Zr-Er coating are grown on TC11 substrate by double-glow plasma surface metallurgy technique, followed by the wear tests at ambient temperature and 500 °C. The data of nanohardness and elastic modulus of the samples are collected by the nano-indentation test. The adhesion strength of coatings is investigated by means of the scratch test. The study of wear resistance is performed using a ball-on-disc wear test system by running against the Si3N4 ball and measured by scanning electron microscope (SEM) and X-ray diffraction (XRD). Experimental results indicate that the nanohardness of the Zr coating and Zr-Er coating are 5.94 GPa and 7.98 GPa, respectively, which are 1.79 times and 2.41 times greater than that of TC11 substrate. Zr coating and Zr-Er coating realize the metallurgical bonding with TC11 substrate with continuous and compact structure. Compared with the Zr coating and TC11, the Zr-Er coating presents the lowest specific wear rates, which are 1.689 × 10-6 mm3 Nm-1 and 1.851 × 10-6 mm3 Nm-1 at ambient temperature and 500 °C respectively, indicating the excellent and improved wear resistance of TC11.

  4. 99mTc-labeling of Peptidomimetic Antagonist to Selectively Target αvβ3 Receptor-Positive Tumor: Comparison of PDA and EDDA as co-Ligands

    PubMed Central

    Shin, In Soo; Maeng, Jin Soo; Jang, Beom-Su; You, Eric; Cheng, Kenneth; Li, King C.P; Wood, Bradford; Carrasquillo, Jorge A.; Danthi, S. Narasimhan; Paik, Chang H.

    2010-01-01

    Objectives The aim of this research was to synthesize radiolabeled peptidomimetic integrin αvβ3 antagonist with 99mTc for rapid targeting of integrin αvβ3 receptors in tumor to produce a high tumor to background ratio. Methods The amino terminus of 4-[2-(3,4,5,6-tetra-hydropyrimidin-2-ylamino)-ethyloxy]benzoyl-2-(S)-[N-(3-amino-neopenta-1-carbamyl)]-aminoethylsulfonyl-amino-β-alanine hydrochloride (IAC) was conjugated with N-hydroxysuccinimide ester of HYNIC and labeled with 99mTc using tricine with either 1,5-pyridinedicarboxylic acid (PDA) or ethylenediamine-N,N′-diacetic acid (EDDA) as the co-ligand. The products, 99mTc EDDA2/HYNIC-IAC (P1) and 99mTc PDA (tricin)/HYNIC-IAC (P2) were subjected to in vitro serum stability, receptor-binding, biodistribution and imaging studies. Results P1 and P2 were synthesized with an overall yield of >80%. P1 was slightly more stable than P2 when incubated in serum at 37 °C for 18 hrs (84 vs 77% intact). The In vitro receptor-binding of P1 was higher than that of P2 (78.02 ± 13.48 vs 51.05 ± 14.05%) when incubated with αvβ3 at a molar excess (0.8 μM). This receptor binding was completely blocked by a molar excess of an unlabeled peptidomimetic antagonist. Their differences shown in serum stability and the receptor-binding appeared to be related to their biological behaviors in tumor uptake and retention; the 1 h tumor uptakes of P1 and P2 were 3.17±0.52 and 2.13±0.17 % ID/g, respectively. P1 was retained in the tumor longer than P2. P1 was excreted primarily through the renal system whereas P2 complex was excreted equally via both renal and hepatobiliary systems. Thus, P1 was retained in the whole-body with 27.25 ± 3.67% ID at 4 h whereas 54.04 ± 3.57% ID of P2 remained in the whole-body at 4 h. This higher whole-body retention of P2 appeared to be resulted from a higher amount of radioactivity retained in liver and intestine. These findings were supported by imaging studies showing higher tumor

  5. Sentinel lymph node accumulation of Lymphoseek and Tc-99m-sulfur colloid using a “2-day” protocol☆

    PubMed Central

    Wallace, Anne M.; Hoh, Carl K.; Limmer, Karl K.; Darrah, Denise D.; Schulteis, Gery; Vera, David R.

    2014-01-01

    Lymphoseek is a receptor-binding radiopharmaceutical specifically designed for sentinel lymph node (SLN) mapping. We conducted a clinical trial which measured the injection site clearance and sentinel lymph node accumulation after a single intradermal injection of Lymphoseek or unfiltered [99mTc]sulfur colloid (TcSC) using a “2-day” protocol for SLN mapping of breast cancer. Eleven patients with breast cancer participated in this study. Five patients received an intradermal administration of 1.0 nmol of 99mTc-labeled Lymphoseek; SLN mapping was performed on four subjects within 19 to 27 h. Six subjects received an intradermal administration of TcSC; SLN mapping was performed on five subjects within 18 to 26 h. Lymphoseek exhibited a significantly (P<.001) faster injection site clearance than TcSC. The mean Lymphoseek clearance half-time was 2.18±1.09 h compared to 57.4±92.8 h for TcSC. The mean sentinel lymph node uptake of Lymphoseek (1.5±1.7%) and TcSC (3.5±3.1%) was statistically equivalent (P=.213). When an intradermal injection is employed, Lymphoseek demonstrated faster injection site clearance than unfiltered [99mTc]sulfur colloid and persistent SLN accumulation for at least 24 h. PMID:19647175

  6. Long-Duration Space Flight Provokes Pathologic Q-Tc Interval Prolongation

    NASA Technical Reports Server (NTRS)

    D'Aunno, DOminick S.; Dougherty, Anne H.; DeBlock, Heidi F.; Meck, Janice V.

    2002-01-01

    Space flight has a profound influence on the cardiovascular and autonomic nervous systems. Alterations in baroreflex function, plasma catecholamine concentrations, and arterial pressure regulation have been observed. Changes in autonomic regulation of cardiac function may lead to serious rhythm disturbances. In fact, ventricular tachycardia has been reported during long-duration space flight. The study aim was to determine the effects of space flight on cardiac conduction. Methods and Results: Electrocardiograms (ECGs) and serum electrolytes were obtained before and after short-duration (SD) (4-16 days) and long-duration (LD) (4-6 months) missions. Holter recordings were obtained from 3 different subjects before, during and after a 4-month mission. P-R, R-R, and Q-T intervals were measured manually in a random, blinded fashion and Bazzet's formula used to correct the Q-T interval (Q-Tc). Space flight had no clinically significant effect on electrolyte concentrations. P-R and RR intervals were decreased after SD flight (p<0.05) and recovered 3 days after landing. In the same subjects, P-R and Q-Tc intervals were prolonged after LD flight (p<0.01). Clinically significant Q-Tc prolongation (>0.44 sec) occurred during the first month of flight and persisted until 3 days after landing (p<0.01). Conclusions - Space flight alters cardiac conduction with more ominous changes seen with LD missions. Alterations in autonomic tone may explain ECG changes associated with space flight. Primary cardiac changes may also contribute to the conduction changes with LD flight. Q-Tc prolongation may predispose astronauts to ventricular arrhythmias during and after long-duration space flight.

  7. Window decompression in laser-heated MagLIF targets

    NASA Astrophysics Data System (ADS)

    Woodbury, Daniel; Peterson, Kyle; Sefkow, Adam

    2015-11-01

    The Magnetized Liner Inertial Fusion (MagLIF) concept requires pre-magnetized fuel to be pre-heated with a laser before undergoing compression by a thick solid liner. Recent experiments and simulations suggest that yield has been limited to date by poor laser preheat and laser-induced mix in the fuel region. In order to assess laser energy transmission through the pressure-holding window, as well as resultant mix, we modeled window disassembly under different conditions using 1D and 2D simulations in both Helios and HYDRA. We present results tracking energy absorption, time needed for decompression, risk of laser-plasma interaction (LPI) that may scatter laser light, and potential for mix from various window thicknesses, laser spot sizes and gas fill densities. These results indicate that using thinner windows (0.5-1 μm windows) and relatively large laser spot radii (600 μm and above) can avoid deleterious effects and improve coupling with the fuel. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the National Nuclear Security Administration under DE-AC04- 94AL85000.

  8. The MagAO Giant Accreting Protoplanet Survey (GAPlanetS): Recent Results

    NASA Astrophysics Data System (ADS)

    Follette, Katherine; Close, Laird; Males, Jared; Morzinski, Katie; Leonard, Clare; MagAO

    2018-01-01

    I will summarize recent results of the MagAO Giant Accreting Protoplant Survey (GAPlanetS), a search for accreting protoplanets at H-alpha inside of transitional disk gaps. These young, centrally-cleared circumstellar disks are often hosted by stars that are still actively accreting, making it likely that any planets that lie in their central cavities will also be actively accreting. Through differential imaging at Hydrogen-alpha using Magellan's visible light adaptive optics system, we have completed the first systematic search for H-alpha emission from accreting protoplanets in fifteen bright Southern hemisphere transitional disks. I will present results from this survey, including a second epoch on the LkCa 15 system that shows several accreting protoplanet candidates.

  9. Origin of the pressure-dependent Tc valley in superconducting simple cubic phosphorus

    NASA Astrophysics Data System (ADS)

    Wu, Xianxin; Jeschke, Harald O.; Di Sante, Domenico; von Rohr, Fabian O.; Cava, Robert J.; Thomale, Ronny

    2018-03-01

    Motivated by recent experiments, we investigate the pressure-dependent electronic structure and electron-phonon (e-ph) coupling for simple cubic phosphorus by performing first-principles calculations within the full potential linearized augmented plane-wave method. As a function of increasing pressure, our calculations show a valley feature in Tc, followed by an eventual decrease for higher pressures. We demonstrate that this Tc valley at low pressures is due to two nearby Lifshitz transitions, as we analyze the band-resolved contributions to the e-ph coupling. Below the first Lifshitz transition, the phonon hardening and shrinking of the γ Fermi surface with s -orbital character results in a decreased Tc with increasing pressure. After the second Lifshitz transition, the appearance of δ Fermi surfaces with 3 d -orbital character generate strong e-ph interband couplings in α δ and β δ channels, and hence lead to an increase of Tc. For higher pressures, the phonon hardening finally dominates, and Tc decreases again. Our study reveals that the intriguing Tc valley discovered in experiment can be attributed to Lifshitz transitions, while the plateau of Tc detected at intermediate pressures appears to be beyond the scope of our analysis. This strongly suggests that aside from e-ph coupling, electronic correlations along with plasmonic contributions may be relevant for simple cubic phosphorus. Our findings hint at the notion that increasing pressure can shift the low-energy orbital weight towards d character, and as such even trigger an enhanced importance of orbital-selective electronic correlations despite an increase of the overall bandwidth.

  10. Development of Tyrosine-Based Radiotracer 99mTc-N4-Tyrosine for Breast Cancer Imaging

    PubMed Central

    Kong, Fan-Lin; Ali, Mohammad S.; Rollo, Alex; Smith, Daniel L.; Zhang, Yinhan; Yu, Dong-Fang; Yang, David J.

    2012-01-01

    The purpose of this study was to develop an efficient way to synthesize 99mTc-O-[3-(1,4,8,11-tetraazabicyclohexadecane)-propyl]-tyrosine (99mTc-N4-Tyrosine), a novel amino acid-based radiotracer, and evaluate its potential in breast cancer gamma imaging. Precursor N4-Tyrosine was synthesized using a 5-step procedure, and its total synthesis yield was 38%. It was successfully labeled with 99mTc with high radiochemical purity (>95%). Cellular uptake of 99mTc-N4-Tyrosine was much higher than that of 99mTc-N4 and the clinical gold standard 18F-2-deoxy-2-fluoro-glucose (18F-FDG) in rat breast tumor cells in vitro. Tissue uptake and dosimetry estimation in normal rats revealed that 99mTc-N4-Tyrosine could be safely administered to humans. Evaluation in breast tumor-bearing rats showed that although 99mTc-N4-Tyrosine appeared to be inferior to 18F-FDG in distinguishing breast tumor tissue from chemical-induced inflammatory tissue, it had high tumor-to-muscle uptake ratios and could detect breast tumors clearly by planar scintigraphic imaging. 99mTc-N4-Tyrosine could thus be a useful radiotracer for use in breast tumor diagnostic imaging. PMID:22496612

  11. Surface tension and phase coexistence properties of the lattice fluid from a virtual site removal Monte Carlo strategy

    NASA Astrophysics Data System (ADS)

    Provata, Astero; Prassas, Vassilis D.; Theodorou, Doros N.

    1997-10-01

    A thin liquid film of lattice fluid in equilibrium with its vapor is studied in 2 and 3 dimensions with canonical Monte Carlo simulation (MC) and Self-Consistent Field Theory (SCF) in the temperature range 0.45Tc to Tc, where Tc the liquid-gas critical temperature. Extending the approach of Oates et al. [Philos. Mag. B 61, 337 (1990)] to anisotropic systems, we develop a method for the MC computation of the transverse and normal pressure profiles, hence of the surface tension, based on virtual removals of individual sites or blocks of sites from the system. Results from implementation of this new method, obtained at very modest computational cost, are in reasonable agreement with exact values and other MC estimates of the surface tension of the 2-d and 3-d model systems, respectively. SCF estimates of the interfacial density profiles, the surface tension, the vapor pressure curve and the binodal curve compare well with MC results away from Tc, but show the expected deviations at high temperatures.

  12. Easy, fast and environmental friendly method for the simultaneous extraction of the 16 EPA PAHs using magnetic molecular imprinted polymers (mag-MIPs).

    PubMed

    Villar-Navarro, Mercedes; Martín-Valero, María Jesús; Fernández-Torres, Rut Maria; Callejón-Mochón, Manuel; Bello-López, Miguel Ángel

    2017-02-15

    An easy and environmental friendly method, based on the use of magnetic molecular imprinted polymers (mag-MIPs) is proposed for the simultaneous extraction of the 16 U.S. EPA polycyclic aromatic hydrocarbons (PAHs) priority pollutants. The mag-MIPs based extraction protocol is simple, more sensitive and low organic solvent consuming compared to official methods and also adequate for those PAHs more retained in the particulate matter. The new proposed extraction method followed by HPLC determination has been validated and applied to different types of water samples: tap water, river water, lake water and mineral water. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Infection with Trypanosoma cruzi TcII and TcI in free-ranging population of lion tamarins (Leontopithecus spp): an 11-year follow-up.

    PubMed

    Lisboa, Cristiane Varella; Monteiro, Rafael Veríssimo; Martins, Andreia Fonseca; Xavier, Samantha Cristina das Chagas; Lima, Valdirene Dos Santos; Jansen, Ana Maria

    2015-05-01

    Here, we present a review of the dataset resulting from the 11-years follow-up of Trypanosoma cruzi infection in free-ranging populations of Leontopithecus rosalia (golden lion tamarin) and Leontopithecus chrysomelas (golden-headed lion tamarin) from distinct forest fragments in Atlantic Coastal Rainforest. Additionally, we present new data regarding T. cruzi infection of small mammals (rodents and marsupials) that live in the same areas as golden lion tamarins and characterisation at discrete typing unit (DTU) level of 77 of these isolates. DTU TcII was found to exclusively infect primates, while TcI infected Didelphis aurita and lion tamarins. The majority of T. cruzi isolates derived from L. rosalia were shown to be TcII (33 out 42) Nine T. cruzi isolates displayed a TcI profile. Golden-headed lion tamarins demonstrated to be excellent reservoirs of TcII, as 24 of 26 T. cruzi isolates exhibited the TcII profile. We concluded the following: (i) the transmission cycle of T. cruzi in a same host species and forest fragment is modified over time, (ii) the infectivity competence of the golden lion tamarin population fluctuates in waves that peak every other year and (iii) both golden and golden-headed lion tamarins are able to maintain long-lasting infections by TcII and TcI.

  14. The Almahata Sitta Polymict Ureilite from the University of Khartoum Collection: Classification, Distribution of Clast Types in the Strewn Field, New Meteorite Types, and Implications for the Structure of Asteroid 2008 TC3

    NASA Technical Reports Server (NTRS)

    Goodrich, C. A.; Fioretti, A. M.; Zolensky, M.; Ross, Daniel K.; Shaddad, M.; Ross, D. K.; Kohl, I.; Young, E.; Kita, N.; Hiroi, T.; hide

    2018-01-01

    The Almahata Sitta (AhS) polymict ureilite fell in 2008 when asteroid 2008 TC3 impacted over Sudan]. It is the first meteorite to originate from an asteroid that had been tracked and studied in space (with spectral classification) before impact, and provides a unique opportunity to correlate properties of meteorites with those of their parent asteroid. More than 700 monolithologic stones from the AhS fall were collected. Of those previously studied, approx. 70% were ureilites and approx. 30% were chondrites. It has been inferred that 2008 TC3 was loosely aggregated and porous and disintegrated in the atmosphere, with only its most coherent clasts falling as stones. However, understanding the structure of this asteroid is limited by incomplete study of the heterogeneous stones, and the loss of most of the mass of the asteroid. The University of Khartoum (UOK) AhS collection contains over >600 AhS stones with find coordinates. We are studying this collection to determine: 1) the proportion of ureilitic to various non-ureilitic stones; 2) the distribution of types of stones in the strewn field; and 3) the compositional and physical structure of 2008 TC3. We report on 61 new stones, including a unique sample that may represent the bulk of the material lost from 2008 TC3.

  15. Lung function declines in patients with pulmonary sarcoidosis and increased respiratory epithelial permeability to sup 99m Tc-DTPA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chinet, T.; Dusser, D.; Labrune, S.

    1990-02-01

    Respiratory epithelial clearance of {sup 99m}Tc-DTPA (RC-Tc-DTPA) and pulmonary function tests (PFT) were determined at intervals of 6 or 12 months in 37 untreated, nonsmoking patients with sarcoidosis over a period of 6 to 36 months. PFT included the measurements of total lung capacity (TLC), vital capacity (VC), FEV1, and diffusing capacity for carbon monoxide. No difference was found between the respiratory clearance of {sup 113m}In-DTPA (2.25 +/- 1.00%/min) and RC-Tc-DTPA (2.29 +/- 1.11%/min) in eight patients with pulmonary sarcoidosis. Pulmonary function decreased 15% or more in at least 2 function tests during 11 follow-up periods, but it remained stablemore » during 47 follow-up periods. In patients whose lung function deteriorated, RC-Tc-DTPA increased to 3.51 +/- 1.55%/min; in contrast, in patients whose lung function remained stable, regardless of the initial values, RC-Tc-DTPA was normal (1.00 +/- 0.50%/min; p less than 0.001). In eight patients who were treated with corticosteroids, RC-Tc-DTPA decreased from 3.48 +/- 1.31%/min to 1.56 +/- 0.64%/min (p less than 0.001), and PFT improved. We conclude that in nonsmokers with pulmonary sarcoidosis, increased RC-Tc-DTPA is not related to dissociation of 99mTc from DTPA, RC-Tc-DTPA is increased when pulmonary function decreases, and, when increased, RC-Tc-DTPA decreases with corticosteroid therapy.« less

  16. [99mTc(V)-DMSA accumulation in gynecomastia].

    PubMed

    Ohta, H

    1998-11-01

    The accumulation of 99mTc(V)-DMSA in bilateral breasts was recognized in a 60-year-old male with drug-induced gynecomastia. There are some reports describing 99mTc(V)-DMSA accumulation in normal female breast, fibrous dysplasia of the breast and metastatic lesions of breast carcinoma, but to my knowledge, there have been no reports describing 99mTc(V)-DMSA accumulation in gynecomastia.

  17. Synthesis, Characterization, and Initial Biological Evaluation of [99m Tc]Tc-Tricarbonyl-labeled DPA-α-MSH Peptide Derivatives for Potential Melanoma Imaging.

    PubMed

    Gao, Feng; Sihver, Wiebke; Bergmann, Ralf; Belter, Birgit; Bolzati, Cristina; Salvarese, Nicola; Steinbach, Jörg; Pietzsch, Jens; Pietzsch, Hans-Jürgen

    2018-06-06

    α-Melanocyte stimulating hormone (α-MSH) derivatives target the melanocortin-1 receptor (MC1R) specifically and selectively. In this study, the α-MSH-derived peptide NAP-NS1 (Nle-Asp-His-d-Phe-Arg-Trp-Gly-NH 2 ) with and without linkers was conjugated with 5-(bis(pyridin-2-ylmethyl)amino)pentanoic acid (DPA-COOH) and labeled with [ 99m Tc]Tc-tricarbonyl by two methods. With the one-pot method the labeling was faster than with the two-pot method, while obtaining similarly high yields. Negligible trans-chelation and high stability in physiological solutions was determined for the [ 99m Tc]Tc-tricarbonyl-peptide conjugates. Coupling an ethylene glycol (EG)-based linker increased the hydrophilicity. The peptide derivatives displayed high binding affinity in murine B16F10 melanoma cells as well as in human MeWo and TXM13 melanoma cell homogenates. Preliminary in vivo studies with one of the [ 99m Tc]Tc-tricarbonyl-peptide conjugates showed good stability in blood and both renal and hepatobiliary excretion. Biodistribution was performed on healthy rats to gain initial insight into the potential relevance of the 99m Tc-labeled peptides for in vivo imaging. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Liquid scintillation counting methodology for 99Tc analysis. A remedy for radiopharmaceutical waste

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khan, Mumtaz; Um, Wooyong

    2015-08-13

    This paper presents a new approach for liquid scintillation counting (LSC) analysis of single-radionuclide samples containing appreciable organic or inorganic quench. This work offers better analytical results than existing LSC methods for technetium-99 ( 99gTc) analysis with significant savings in analysis cost and time. The method was developed to quantify 99gTc in environmental liquid and urine samples using LSC. Method efficiency was measured in the presence of 1.9 to 11,900 ppm total dissolved solids. The quench curve was proved to be effective in the case of spiked 99gTc activity calculation for deionized water, tap water, groundwater, seawater, and urine samples.more » Counting efficiency was found to be 91.66% for Ultima Gold LLT (ULG-LLT) and Ultima Gold (ULG). Relative error in spiked 99gTc samples was ±3.98% in ULG and ULG-LLT cocktails. Minimum detectable activity was determined to be 25.3 mBq and 22.7 mBq for ULG-LLT and ULG cocktails, respectively. A pre-concentration factor of 1000 was achieved at 100°C for 100% chemical recovery.« less

  19. Evaluation of (99m)Tc-HYNIC-TMTP1 as a tumor-homing imaging agent targeting metastasis with SPECT.

    PubMed

    Li, Fei; Cheng, Teng; Dong, Qingjian; Wei, Rui; Zhang, Zhenzhong; Luo, Danfeng; Ma, Xiangyi; Wang, Shixuan; Gao, Qinglei; Ma, Ding; Zhu, Xiaohua; Xi, Ling

    2015-03-01

    TMTP1 (NVVRQ) is a novel tumor-homing peptide, which specifically targets tumor metastases, even at the early stage of occult metastasis foci. Fusing TMTP1 to therapeutic peptides or proteins can increase its anti-cancer efficacy both in vivo and in vitro. Here, we labeled TMTP1 with (99m)Tc to evaluate its targeting properties in an ovarian cancer xenograft tumor mouse model and a gastric cancer xenograft mouse model. The invasion ability of SKOV3 and highly metastatic SKOV3.ip cell lines were performed by the Transwell Invasion Assays, and then Rhodamine-TMTP1 was used to detect its affinity to these two cells. Using the co-ligand ethylenediamine-N, N'-diacetic acid (EDDA) and the bifunctional chelator 6-hydrazinonicotinic acid (HYNIC), the TMTP1 peptide was labeled with (99m)Tc. A cell-binding assay was performed by incubating cancer cells with (99m)Tc-HYNIC-TMTP1 with or without an excess dose of cold HYNIC-TMTP1. To evaluate the probe in vivo, nude mice bearing SKOV3, SKOV3.ip and MNK-45 tumor cells were established and subjected to SPECT imaging after injection with (99m)Tc-HYNIC-TMTP1. Ex vivo γ-counting of dissected tissues from the mice was used to evaluate its biodistribution. (99m)Tc-HYNIC-TMTP1 was successfully synthesized. The radiotracer also exhibited high hydrophilicity and excellent stability in vitro and in vivo. It has strong affinity to highly metastatic cancer cell lines but not to poorly metastatic cell lines. After mice were injected with (99m)Tc-HYNIC-TMTP1, non-invasive SPECT imaging detected SKOV3.ip and MNK-45 xenograft tumors but not SKOV3 xenograft tumors. This result can be inhibited by excess HYNIC-TMTP1. The uptake of (99m)Tc-HYNIC-TMTP1 in SKOV3.ip xenograft tumors was 0.182±0.017% ID/g at 2h p.i. with high renal uptake (74.32±15.05% ID/g at 2h p.i.). (99m)Tc-HYNIC-TMTP1 biodistribution and SPECT imaging demonstrated its ability to target highly metastatic tumors. Therefore, metastasis can be non-invasively investigated by SPECT

  20. Osteomalacia-inducing renal clear cell carcinoma uncovered by 99mTc-Hydrazinonicotinyl-Tyr3-octreotide (99mTc-HYNIC-TOC) scintigraphy.

    PubMed

    Jin, Xiaona; Jing, Hongli; Li, Fang; Zhuang, Hongming

    2013-11-01

    Most osteomalacia-causing tumors are small, benign mesenchymal neoplasms, which are commonly located in the extremities or craniofacial regions. An 18-year-old male patient with suspicion of tumor-induced osteomalacia underwent (99m)Tc-HYNIC-TOC scintigraphy to search potential culprit tumor. The images showed a large activity in the region of the left kidney. The lesion was resected and a clear cell renal cell carcinoma was found. One year after the left nephrectomy, the patient was tumor-free without symptoms of osteomalacia.

  1. Diagnostic accuracy of [99mTc]Tc-Sestamibi in the assessment of thyroid nodules

    PubMed Central

    Yordanova, Anna; Mahjoob, Soha; Lingohr, Philipp; Kalff, Jörg; Türler, Andreas; Palmedo, Holger; Biersack, Hans-Jürgen; Kristiansen, Glen; Farahati, Jamshid; Essler, Markus; Ahmadzadehfar, Hojjat

    2017-01-01

    [99mTc]Tc-Sestamibi (MIBI) is an increasingly used tool for evaluation of thyroid nodules. However, there is a lack of evidence about the accuracy of this method in the European population. The aim of this study was to assess the utility of MIBI for the differentiation of thyroid nodules in a large cohort. 161 patients underwent MIBI, followed by a thyroidectomy. We used a dual phase MIBI protocol. Interpretation of the images included a scoring system from 0 (absent) to 3 (increased); this was to provide a scale for the uptake of the thyroid nodule in comparison to the paranodular tissue. Additionally, we evaluated the tracer uptake trend in late images compared to early images. We used the final histopathology as the reference standard. Scores 0-1 in early images, scores 0-2 in late images, and an absence of increasing uptake in the thyroid nodule in late images, showed the best predictive values to exclude malignancy, respectively (negative predictive value (NPV) 89%). Highest sensitivity (91%) for malignant nodules was evident in early images with a score 1-3. Highest specificity (91%) was obtained when the negative was defined as an absence of uptake-increase, in the late images. This study confirms that the most valuable feature of MIBI is the high NPV. Thus, with the appropriate interpretation method, high sensitivity and specificity, and moderate PPV can be obtained. PMID:29212258

  2. Magnetic flux and heat losses by diffusive, advective, and Nernst effects in MagLIF-like plasma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Velikovich, A. L., E-mail: sasha.velikovich@nrl.navy.mil; Giuliani, J. L., E-mail: sasha.velikovich@nrl.navy.mil; Zalesak, S. T.

    2014-12-15

    The MagLIF approach to inertial confinement fusion involves subsonic/isobaric compression and heating of a DT plasma with frozen-in magnetic flux by a heavy cylindrical liner. The losses of heat and magnetic flux from the plasma to the liner are thereby determined by plasma advection and gradient-driven transport processes, such as thermal conductivity, magnetic field diffusion and thermomagnetic effects. Theoretical analysis based on obtaining exact self-similar solutions of the classical collisional Braginskii's plasma transport equations in one dimension demonstrates that the heat loss from the hot plasma to the cold liner is dominated by the transverse heat conduction and advection, andmore » the corresponding loss of magnetic flux is dominated by advection and the Nernst effect. For a large electron Hall parameter ω{sub e}τ{sub e} effective diffusion coefficients determining the losses of heat and magnetic flux are both shown to decrease with ω{sub e}τ{sub e} as does the Bohm diffusion coefficient, which is commonly associated with low collisionality and two-dimensional transport. This family of exact solutions can be used for verification of codes that model the MagLIF plasma dynamics.« less

  3. Inhibitory effect of trans-caryophyllene (TC) on leukocyte-endothelial attachment.

    PubMed

    Zhang, Zhen; Yang, Chunfeng; Dai, Xinlun; Ao, Yu; Li, Yumei

    2017-08-15

    trans-Caryophyllene (TC) is a major component found in the essential oils of many spices and foods/medicinal plants. It is a natural sesquiterpene and has been the subject of numerous studies. However, the effects of TC on vascular inflammation remain unknown. In this study, we reported that TC treatment in human umbilical vein endothelial cells (HUVECs) prevented attachment of monocytic leukemia cell line THP-1 cells to endothelial cells. In addition, in vivo results indicate that TC inhibited macrophage infiltration to the aortic surface and reduced total serum levels of cholesterol and triglycerides. Importantly, administration of TC could inhibit the induction of vascular cell adhesion molecule-1 (VCAM-1) both in vitro and in vivo. Notably, our data indicate that the inhibitory effects of TC on the expression of VCAM-1 are mediated by the JAK2/STAT1/IRF-1 pathway. TC is a specific agonist of the type 2 cannabinoid receptor (CB2R). Importantly, we further verified that the inhibitory effects of TC on the expression of IRF-1 and VCAM-1 are dependent on activation of CB2R. Inhibition of CB2R by either specific inhibitors or RNA interference abolished the inhibitory effects of TC on the expression of IRF-1 and VCAM-1. Our results suggest that TC might have a capacity to suppress the development of atherosclerosis. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. High cell density cultivation of a novel Aurantiochytrium sp. strain TC 20 in a fed-batch system using glycerol to produce feedstock for biodiesel and omega-3 oils.

    PubMed

    Lee Chang, Kim Jye; Dumsday, Geoff; Nichols, Peter D; Dunstan, Graeme A; Blackburn, Susan I; Koutoulis, Anthony

    2013-08-01

    A recently isolated Australian Aurantiochytrium sp. strain TC 20 was investigated using small-scale (2 L) bioreactors for the potential of co-producing biodiesel and high-value omega-3 long-chain polyunsaturated fatty acids. Higher initial glucose concentration (100 g/L compared to 40 g/L) did not result in markedly different biomass (48 g/L) or fatty acid (12-14 g/L) yields by 69 h. This comparison suggests factors other than carbon source were limiting biomass production. The effect of both glucose and glycerol as carbon sources for Aurantiochytrium sp. strain TC 20 was evaluated in a fed-batch process. Both glucose and glycerol resulted in similar biomass yields (57 and 56 g/L, respectively) by 69 h. The agro-industrial waste from biodiesel production-glycerol-is a suitable carbon source for Aurantiochytrium sp. strain TC 20. Approximately half the fatty acids from Aurantiochytrium sp. strain TC 20 are suitable for development of sustainable, low emission sources of transportation fuels and bioproducts. To further improve biomass and oil production, fortification of the feed with additional nutrients (nitrogen sources, trace metals and vitamins) improved the biomass yield from 56 g/L (34 % total fatty acids) to 71 g/L (52 % total fatty acids, cell dry weight) at 69 h; these yields are to our knowledge around 70 % of the biomass yields achieved, however, in less than half of the time by other researchers using glycerol and markedly greater than achieved using other industrial wastes. The fast growth and suitable fatty acid profile of this newly isolated Aurantiochytrium sp. strain TC 20 highlights the potential of co-producing the drop-in biodiesel and high value omega-3 oils.

  5. Infection with Trypanosoma cruzi TcII and TcI in free-ranging population of lion tamarins (Leontopithecus spp): an 11-year follow-up

    PubMed Central

    Lisboa, Cristiane Varella; Monteiro, Rafael Veríssimo; Martins, Andreia Fonseca; Xavier, Samantha Cristina das Chagas; Lima, Valdirene dos Santos; Jansen, Ana Maria

    2015-01-01

    Here, we present a review of the dataset resulting from the 11-years follow-up of Trypanosoma cruzi infection in free-ranging populations of Leontopithecus rosalia (golden lion tamarin) and Leontopithecus chrysomelas (golden-headed lion tamarin) from distinct forest fragments in Atlantic Coastal Rainforest. Additionally, we present new data regarding T. cruzi infection of small mammals (rodents and marsupials) that live in the same areas as golden lion tamarins and characterisation at discrete typing unit (DTU) level of 77 of these isolates. DTU TcII was found to exclusively infect primates, while TcI infected Didelphis aurita and lion tamarins. The majority of T. cruzi isolates derived from L. rosalia were shown to be TcII (33 out 42) Nine T. cruzi isolates displayed a TcI profile. Golden-headed lion tamarins demonstrated to be excellent reservoirs of TcII, as 24 of 26 T. cruzi isolates exhibited the TcII profile. We concluded the following: (i) the transmission cycle of T. cruzi in a same host species and forest fragment is modified over time, (ii) the infectivity competence of the golden lion tamarin population fluctuates in waves that peak every other year and (iii) both golden and golden-headed lion tamarins are able to maintain long-lasting infections by TcII and TcI. PMID:25946156

  6. Production and concentration of monoacylglycerols rich in omega-3 polyunsaturated fatty acids by enzymatic glycerolysis and molecular distillation.

    PubMed

    Solaesa, Ángela García; Sanz, María Teresa; Falkeborg, Mia; Beltrán, Sagrario; Guo, Zheng

    2016-01-01

    Production of monoacylglycerols (MAGs) rich in ω-3 polyunsaturated fatty acids (n-3 PUFAs) was conducted through short path distillation (SPD) of an acylglycerol mixture (containing 67% MAGs) produced by enzymatic glycerolysis of sardine oil with glycerol. A stepwise SPD process in a UIC KDL 5 system (vacuum 10(-3)mbar, feeding flow 1.0 mL/min) was proceeded: the first distillation performed at evaporator temperature (TE) of 110 °C to remove glycerol completely and most of FFAs; and the second distillation at optimized TE 155 °C; resulting in a stream distillate with 91% purity and 94% overall recovery of MAGs. This work also demonstrated that SPD is able to concentrate n-3 PUFAs in MAG form by distilling at proper TE e.g. 125 °C, where n-3 PUFAs are concentrated in the residues. Moreover, this work mapped out a complete processing diagram for scalable production of n-3 PUFAs enriched MAGs as potential food emulsifier and ingredient. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Multi-Objective data analysis using Bayesian Inference for MagLIF experiments

    NASA Astrophysics Data System (ADS)

    Knapp, Patrick; Glinksy, Michael; Evans, Matthew; Gom, Matth; Han, Stephanie; Harding, Eric; Slutz, Steve; Hahn, Kelly; Harvey-Thompson, Adam; Geissel, Matthias; Ampleford, David; Jennings, Christopher; Schmit, Paul; Smith, Ian; Schwarz, Jens; Peterson, Kyle; Jones, Brent; Rochau, Gregory; Sinars, Daniel

    2017-10-01

    The MagLIF concept has recently demonstrated Gbar pressures and confinement of charged fusion products at stagnation. We present a new analysis methodology that allows for integration of multiple diagnostics including nuclear, x-ray imaging, and x-ray power to determine the temperature, pressure, liner areal density, and mix fraction. A simplified hot-spot model is used with a Bayesian inference network to determine the most probable model parameters that describe the observations while simultaneously revealing the principal uncertainties in the analysis. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology and Engineering Solutions of Sandia, LLC., a wholly owned subsidiary of Honeywell International, Inc., for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA-0003525.

  8. Experimental partitioning of Tc, Mo, Ru, and Re between solid and liquid during crystallization in Fe-Ni-S 1

    NASA Astrophysics Data System (ADS)

    Lazar, C.; Walker, D.; Walker, R. J.

    2004-02-01

    Technetium isotopes 97Tc, 98Tc and 99Tc decay to 97Mo, 98Ru and 99Ru, with half-lives of 2.6 My, 4.1 My, and 0.21 My respectively. If there were early solar system processes that resulted in significant fractionation of Tc from the daughter elements, decay of extant Tc could have led to the creation of Mo and Ru isotopic heterogeneities. To assess the potential of metallic core crystallization to fractionate these elements, we examine the partitioning behavior of Tc relative to Re, Mo and Ru in the Fe-Ni-S system between solid metal and liquid metal alloy. The experimental evidence shows that Tc behaves more like the modestly compatible siderophile element Ru than the more highly compatible siderophile element Re, and that Tc is substantially more compatible than Mo. We also demonstrate a pressure effect in the partitioning of Mo during the crystallization of Fe-Ni-S melts. For a sulfur concentration in the liquid fraction of the core of 10 wt% (16.3 at%), the Jones and Malvin (1990) parameter is -ln(1-2 × 1.09 × 0.163) ≅ 0.44, which yields: D(Re) ≅ 4.1; D(Ru) ≅ 2.3; D(Tc) ≅ 1.7; D(Mo) Lo-P ≅ 1.0;.and D(Mo) Hi-P ≅ 0.5. Our results suggest that detectable Tc-induced isotopic anomalies (≥0.1 ɛ unit) in Ru and Mo could only be produced by unrealistically extreme degrees of crystallization of metal during asteroidal core fractionation, regardless of the time scales and initial Tc abundances involved.

  9. TC-tuned biocompatible suspension of La0.73Sr0.27MnO3 for magnetic hyperthermia.

    PubMed

    Prasad, N K; Rathinasamy, K; Panda, D; Bahadur, D

    2008-05-01

    La(1-x)Sr(x)MnO(3), a ferromagnet with high magnetization and Curie temperature T(C) below 70 degrees C, enables its use for magnetic hyperthermia treatment of cancer with a possibility of in vivo temperature control. We found that La(0.73)Sr(0.27)MnO(3) particles of size range 20-100 nm showed saturation magnetization around 38 emu/g at 20 kOe and a T(C) value of 45 degrees C. Aqueous suspension of these nanoparticles was prepared using a polymer, acrypol 934, and the biocompatibility of the suspension was examined using HeLa cells. A good heating ability of the magnetic suspension was obtained in the presence of AC magnetic field, and it was found to increase with the amplitude of field. The suspension having concentration of 0.66 mg/mL (e.g., 0.66 mg of nanoparticles with acropyl per milliliter of culture media) was observed to be biocompatible even after 96 h of treatment, as estimated by sulforhodamine B and trypan blue dye exclusion assays. Further, the treatment with the aforementioned concentration did not alter the microtubule cytoskeleton or the nucleus of the cells. However, the bare particles (concentration of 0.66 mg of nanoparticles per milliliter of culture media, but without acropyl) decreased the viability of cell significantly. Our in vitro studies suggest that the suspension (concentration of 0.66 mg/mL) may further be analyzed for in vivo studies. Copyright 2007 Wiley Periodicals, Inc.

  10. Study of laser preheating dependence on laser wavelength and intensity for MagLIF

    NASA Astrophysics Data System (ADS)

    Wei, M. S.; Harvey-Thompson, A. J.; Glinsky, M.; Nagayama, T.; Weis, M.; Geissel, M.; Peterson, K.; Fooks, J.; Krauland, C.; Giraldez, E.; Davies, J.; Campbell, E. M.; Bahr, R.; Edgell, D.; Stoeckl, C.; Glebov, V.; Emig, J.; Heeter, R.; Strozzi, D.

    2017-10-01

    The magnetized liner inertial fusion (MagLIF) scheme requires preheating underdense fuel to 100's eV temperature by a TW-scale long pulse laser via collisional absorption. To better understand how laser preheat scales with laser wavelength and intensity as well as to provide data for code validation, we have conducted a well-characterized experiment on OMEGA to directly compare laser propagation, energy deposition and laser plasma instabilities (LPI) using 2 ω (527 nm) and 3 ω (351 nm) lasers with intensity in the range of (1-5)x1014 Wcm-2. The laser beam (1 - 1.5 ns square pulse) enters the gas-filled plastic liner though a 2-µm thick polyimide window to heat an underdense Ar-doped deuterium gas with electron density of 5.5% of critical density. Laser propagation and plasma temperature are diagnosed by time-resolved 2D x-ray images and Ar emission spectroscopy, respectively. LPI is monitored by backscattering and hard x-ray diagnostics. The 2 ω beam propagation shows a noticeable larger lateral spread than the 3 ω beam, indicating laser spray due to filamentation. LPI is observed to increase with laser intensity and the 2 ω beam produces more hot electrons compared with the 3 ω beam under similar conditions. Results will be compared with radiation hydrodynamic simulations. Work supported by the U.S. DOE ARPA-E and NNSA.

  11. Getters for Tc and I Removal from Liquid Waste

    NASA Astrophysics Data System (ADS)

    Qafoku, N. P.; Asmussen, M.; Lawter, A.; Neeway, J.; Smith, G.

    2015-12-01

    A cementitious waste form, Cast Stone, is being evaluated as a possible supplemental waste form for the low activity waste (LAW) at the Hanford Site, which contains significant amounts of radioactive 99Tc and 129I, as part of the tank waste cleanup mission. To improve the retention of Tc and/or I in Cast Stone, materials with a high affinity for Tc and/or I, termed "getters," can be added to decrease the rate of contaminant release and diffusivity, and improve Cast Stone performance. A series of kinetic batch sorption experiments was performed to determine the effectiveness of the getter materials. Several Tc getters [blast furnace slag, Sn (II) apatite, SnCl2, nanoporous Sn phosphate, KMS-2 (a potassium-metal-sulfide), and Sn(II) hydroxyapatite] and I getters [layered Bi hydroxide, natural argentite mineral, synthetic argentite, Ag-impregnated carbon, and Ag-exchanged zeolite] were tested in different solution media, 18.2 MΩ DI H2O and a caustic LAW waste simulant containing 6.5 M Na or 7.8 M Na. The experiments were conducted at room temperature in the presence or absence of air. Results indicated that most Tc getters (with the exception of KMS-2) performed better in the DI H2O solution than in the 6.5 and 7.8 M Na LAW simulant. In addition, Tc sequestration may be affected by the presence of other redox sensitive elements that were present in the LAW simulant, such as Cr. The Tc getter materials have been examined through various solid-state characterization techniques such as XRD, SEM/EDS, XANES and EXAFS which provided evidence for plausible mechanisms of aqueous Tc removal. The results indicated that the Tc precipitates differ depending on the getter material and that Tc(VII) is reduced to Tc(IV) in most of the getters but to a differing extents. For the I getters, Ag-exchanged zeolite and synthetic argentite were the most effective ones. The other I getters showed limited effectiveness for sorbing I under the high ionic strength and caustic

  12. [99mTc-octreotide receptor scintigraphy in NCI-H446 small cell lung cancer nude mice model].

    PubMed

    Li, Chao; Zuo, Shuyao; Wang, Xufu; Liu, Xinfeng; Wang, Guoming; Wu, Fengyu

    2015-01-01

    For highly aggressive small cell lung cancer (SCLC), early diagnosis is important for its prognosis, but the current inspection methods are more limited, with poor specificity of the traditional imaging methods, and the high cost of PET/CT, difficult to popularization and application. SCLC is kind of neuroendocrine tumors, high expression of somatostatin receptors, which is the cornerstone of its early molecular imaging diagnosis. The aim of this study is to observe the biodistribution and metabolism of 99mTc-octreotide in normal and the human SCLC bearing nude mice. Dynamic and static scintigraphy at 0.5 h, 2 h, 3 h, 4 h were performed in both normal and tumor bearing nude mice after intravenous injection of 99mTc-octreotide. The technique of drawing region of interest (ROI) was used to obtain the averaged pixel counts and the activity-time (A-T) curve of brain, heart, lung, liver, kidney, tumor, respectively. ① The biodistribution study in normal nude mice showed highest uptake in kidney and liver, lower in lung and heart, lowest in brain. Most 99mTc-octreotide was excreted via kidney. ② All tumors were displayed clearly at 3 h postinjection of 99mTc-octreotide. The averaged T/N ratio at 0.5 h, 2 h, 3 h, 4 h postinjection of 99mTc-octreotide was 1.163 ± 0.03, 2.08 ± 0.12, 3.03 ± 0.23, 2.689 ± 0.31, respectively (F=51.69, P<0.000,1). The radioactivity of tumor was lower than liver, and similar with the lung. The curve of tumor showed a radioactivity peak at 2 min-3 min postinjection. 99mTc-octreotide receptor imaging on nude mice bearing SCLC shares high positive rate, especially at 3 h postinjection.

  13. Modifications of Atlantic salmon by-product oil for obtaining different ω-3 polyunsaturated fatty acids concentrates: An approach to comparative analysis.

    PubMed

    Haq, Monjurul; Park, Seul-Ki; Kim, Min-Jung; Cho, Yeon-Jin; Chun, Byung-Soo

    2018-04-01

    Omega-3 polyunsaturated fatty acids (ω-3 PUFAs) rich 2-monoacylglycerols (2-MAG), omega-3 polyunsaturated free fatty acids (ω-3 PUFFAs) concentrate, and PUFA enriched acylglycerols were prepared from salmon frame bone oil (SFBO) by enzymatic alcoholysis, urea complexation, and enzymatic esterification, respectively. The yields of 2-MAG, ω-3 PUFFAs concentrate, and PUFA enriched acylglycerols were 40.25, 16.52, and 15.65%, respectively. ω-3 PUFFAs concentrate and PUFA enriched acylglycerols showed darker red color than SFBO and 2-MAG due to aggregation of astaxanthin pigment in ω-3 PUFFAs concentrate during urea complexation. The viscosity and specific gravity of SFBO and PUFA enriched acylglycerols showed similar values whereas 2-MAG and ω-3 PUFFAs showed significantly (p < 0.05) lower values. Stability parameters like acid value, peroxide value, free fatty acid value, and p-anisidine value of SFBO and ω-3 PUFAs concentrates were within acceptable limits except extreme high acid value and free fatty acid value of ω-3 PUFFAs concentrate. Thermogravimetric analysis showed similar and higher thermal stability of SFBO and PUFA enriched acylglycerols than 2-MAG and ω-3 PUFFAs concentrate. The ω-3 PUFAs content in 2-MAG, ω-3 PUFFAs concentrate, and PUFA enriched acylglycerols was increased to 20.81, 52.96, and 51.74% respectively from 13.54% in SFBO. ω-3 PUFFAs concentrate and PUFA enriched acylglycerols showed higher DPPH and ABTS radical scavenging activity than SFBO and 2-MAG. The results obtained from this study suggest the production of PUFA enriched acylglycerols rich in ω-3 PUFAs supplements from fish oil for human and pet animals. Copyright © 2017. Published by Elsevier B.V.

  14. Tc-NGA imaging in liver transplantation: preliminary clinical experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woodle, E.S.; Ward, R.E.; Stadalnik, R.C.

    1989-03-01

    Technetium-99m galactosyl-neoglycoalbumin (Tc-NGA) is a new liver imaging agent that binds to hepatic-binding protein, a hepatocyte-specific membrane receptor. The purpose of this study was to determine the potential of Tc-NGA imaging in clinical liver transplantation. A total of 25 studies were performed in nine patients. Imaging studies performed in the early posttransplant period in patients with good hepatic allograft function revealed diffuse patchiness in tracer distribution, a manifestation of preservation damage. Left lobar infarction was demonstrated within a few hours of ischemic injury. Right posterior segmental infarction was seen in another patient. Comparison of kinetic, clinical, and biochemical data revealedmore » good correlation between hepatic allograft function and Tc-NGA kinetics. Major kinetic alterations were noted during periods of preservation injury, hepatic infarction, and acute rejection. These studies indicate: (1) major alterations in Tc-NGA kinetics occur during preservation injury, hepatic infarction, and acute rejection, and (2) Tc-NGA kinetic data appear to provide an accurate reflection of hepatic allograft function. Tc-NGA imaging has the advantages of being noninvasive and of utilizing standard nuclear medicine instrumentation, including portable imaging devices. In conclusion, Tc-NGA imaging provides a promising noninvasive approach for evaluation of liver function in patients undergoing hepatic transplantation.« less

  15. High Tc superconducting materials and devices

    NASA Technical Reports Server (NTRS)

    Haertling, Gene H.

    1990-01-01

    The high Tc Y1Ba2Cu3O(7-x) ceramic materials, initially developed in 1987, are now being extensively investigated for a variety of engineering applications. The superconductor applications which are presently identified as of most interest to NASA-LaRC are low-noise, low thermal conductivity grounding links; large-area linear Meissner-effect bearings; and sensitive, low-noise sensors and leads. Devices designed for these applications require the development of a number of processing and fabrication technologies. Included among the technologies most specific to the present needs are tapecasting, melt texturing, magnetic field grain alignment, superconductor/polymer composite fabrication, thin film MOD (metal-organic decomposition) processing, screen printing of thick films, and photolithography of thin films. The overall objective of the program was to establish a high Tc superconductivity laboratory capability at NASA-LaRC and demonstrate this capability by fabricating superconducting 123 material via bulk and thin film processes. Specific objectives include: order equipment and set up laboratory; prepare 1 kg batches of 123 material via oxide raw material; construct tapecaster and tapecaster 123 material; fabricate 123 grounding link; fabricate 123 composite for Meissner linear bearing; develop 123 thin film processes (nitrates, acetates); establish Tc and Jc measurement capability; and set up a commercial use of space program in superconductivity at LaRC. In general, most of the objectives of the program were met. Finally, efforts to implement a commercial use of space program in superconductivity at LaRC were completed and at least two industrial companies have indicated their interest in participating.

  16. 77 FR 54908 - TC Offshore, LLC; Notice Establishing Deadline for Comments

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-06

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. RP12-908-000] TC Offshore, LLC; Notice Establishing Deadline for Comments On August 29, 2012, TC Offshore, LLC (TC Offshore... is hereby given that participants in the captioned proceedings may file comments to TC Offshsore's...

  17. 75 FR 54873 - Notice of Availability of Final NPDES General Permits MAG910000 and NHG910000 for Discharges From...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-09

    ... MAG910000 and NHG910000 for Discharges From Remediation Activities in the Commonwealth of Massachusetts (Including Both Commonwealth and Indian Country Lands) and the State of New Hampshire: The Remediation... Elimination System (NPDES) general permits for discharges from remediation activities to certain waters of the...

  18. Structural stability and mechanical properties of technetium mononitride (TcN)

    NASA Astrophysics Data System (ADS)

    Soni, Shubhangi; Choudhary, K. K.; Kaurav, Netram

    2018-05-01

    Among the nitrides, 3d and 4d transition metal nitrides have been investigated both experimentally and theoretically due to their predominant performances and enormous applications. In the present paper, we have attempted to predict the structural stability and mechanical properties of technetium mononitride (TcN) using an effective interionic interaction potential, which includes the long range Coulomb, van der Waals (vdW) interaction and the short-range repulsive interaction upto second-neighbor ions within the Hafemeister and Flygare approach. Our theoretical approach reveals the structural phase transition of the TcN B3 to B1 structure, wherein, the Gibbs' free energies of both the structures were minimized. The variations of elastic constants with pressure follow a systematic trend identical to that observed in other compounds of ZnS type structure family.

  19. Utility of ⁹⁹mTc-human serum albumin diethylenetriamine pentaacetic acid SPECT for evaluating endoleak after endovascular abdominal aortic aneurysm repair.

    PubMed

    Nakai, Motoki; Sato, Hirotatsu; Sato, Morio; Ikoma, Akira; Sonomura, Tetsuo; Nishimura, Yoshiharu; Okamura, Yoshitaka

    2015-01-01

    The purpose of this study was to assess the utility of (99m)Tc-human serum albumin diethylenetriamine pentaacetic acid ((99m)Tc-HSAD) SPECT in the detection of endoleaks after endovascular abdominal aortic aneurysm repair. Fifteen patients (11 men, four women) with aneurysm sac expansion of 5 mm or greater after endovascular abdominal aortic aneurysm repair underwent three-phase CT, (99m)Tc-HSAD SPECT, and CT during aortography. Sensitivity calculations for three-phase CT and (99m)Tc-HSAD SPECT were performed with CT during aortography as the reference standard. The volume of each endoleak was measured with CT during aortography. Seven subjects underwent embolization with N-butyl cyanoacrylate (NBCA)-Lipiodol (ethiodized oil, Guerbet and metallic coils. Three-phase CT and (99m)Tc-HSAD SPECT were repeated after embolization to assess their efficacy. Endoleaks were interpreted as perigraft radioisotope accumulation in 12 patients (80.0%) on (99m)Tc-HSAD SPECT images, in 13 patients (86.7%) on three-phase CT images, and in 15 patients (100%) on CT during aortography. The mean endoleak volume visualized with (99m)Tc-HSAD SPECT was 8.37 cm(3) (range, 5.2-15.1 cm(3)), and the volume not visualized was 3.47 cm(3) (2.5-4.6 cm(3)), a statistically significant difference (p = 0.019). In two patients, (99m)Tc-HSAD SPECT depicted endoleaks evident at delayed phase CT during aortography but not at three-phase CT, suggesting they were slow-filling endoleaks. Accumulation of (99m)Tc-HSAD corresponding to endoleaks disappeared after embolization, but CT evaluation of embolization was impeded by artifacts of NBCA-Lipiodol and metallic coils. Technetium-99m-labeled HSAD SPECT proved less sensitive than three-phase CT but depicted endoleaks with volumes 5.2 cm(3) or greater as perigraft radioisotope accumulation. Slow-filling endoleaks can be visualized with (99m)Tc-HSAD SPECT, which can be used to evaluate the efficacy of embolization.

  20. 75 FR 5855 - Proposed Collection; Comment Request for Form 8038-TC

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-04

    ... 8038-TC AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Notice and request for comments... comments concerning Form 8038-TC, Information Return for Tax Credit Bonds. DATES: Written comments should...: Form 8038-TC. Abstract: Form 8038-TC will be used by issuers of qualified tax- exempt credit bonds...

  1. Tc-99m Labeled carrier for imaging

    DOEpatents

    Henze, Eberhard

    1984-01-01

    Novel radionuclide imaging agents, having particular application for lymphangiography are provided by non-covalently binding Tc-99m to a pharmaceutically acceptable cross-linked polysaccharide. Upon injection of the Tc-99m labeled polysaccharide into the blood stream, optimum contrast can be obtained within one hour.

  2. Imaging discordance between hepatic angiography versus Tc-99m-MAA SPECT/CT: a case series, technical discussion and clinical implications.

    PubMed

    Kao, Yung Hsiang; Tan, Eik Hock; Teo, Terence Kiat Beng; Ng, Chee Eng; Goh, Soon Whatt

    2011-11-01

    During pre-therapy evaluation for yttrium-90 (Y-90) radioembolization, it is uncommon to find severe imaging discordance between hepatic angiography versus technetium-99m-macroaggregated albumin (Tc-99m-MAA) single photon emission computed tomography with integrated low-dose CT (SPECT/CT). The reasons for severe imaging discordance are unclear, and literature is scarce. We describe 3 patients with severe imaging discordance, whereby tumor angiographic contrast hypervascularity was markedly mismatched to the corresponding Tc-99m-MAA SPECT/CT, and its clinical impact. The incidence of severe imaging discordance at our institution was 4% (3 of 74 cases). We postulate that imaging discordance could be due to a combination of 3 factors: (1) different injection rates between soluble contrast molecules versus Tc-99m-MAA; (2) different arterial flow hemodynamics between soluble contrast molecules versus Tc-99m-MAA; (3) eccentric release position of Tc-99m-MAA due to microcatheter tip location, inadvertently selecting non-target microparticle trajectories. Tc-99m-MAA SPECT/CT more accurately represents hepatic microparticle biodistribution than soluble contrast hepatic angiography and should be a key criterion in patient selection for Y-90 radioembolization. Tc-99m-MAA SPECT/CT provides more information than planar scintigraphy to guide radiation planning and clinical decision making. Severe imaging discordance at pre-therapy evaluation is ominous and should be followed up by changes to the final vascular approach during Y-90 radioembolization.

  3. 99mTc-HYNIC-TOC imaging in the evaluation of pancreatic masses which are potential neuroendocrine tumors.

    PubMed

    Qiao, Zhen; Zhang, Jingjing; Jin, Xiaona; Huo, Li; Zhu, Zhaohui; Xing, Haiqun; Li, Fang

    2015-05-01

    The aim of this investigation was to determine the accuracy of the findings and the diagnoses of Tc-hydrazinonicotinyl-Tyr3-octreotide scan (Tc-HYNIC-TOC imaging) in patients with pancreatic masses which were potential neuroendocrine tumors. Records of total 20 patients with pancreatic masses were retrospectively reviewed. All of the patients had been revealed by abdominal contrast CT and possibility of neuroendocrine tumors could not be excluded by CT imaging before Tc-HYNIC-TOC imaging. Tc-HYNIC-TOC imaging was performed at 1 and 4 hours post-tracer injection, and SPECT/CT images of the abdomen were also acquired. The image findings were compared to final diagnoses which were made from pathological examination. Among all 20 pancreatic masses evaluated, there were 16 malignant lesions which included 1 ductal adenocarcinoma and 15 neuroendocrine tumors. Tc-HYNIC-TOC imaging identified 14 of 15 pancreatic neuroendocrine tumors and excluded 4 of 5 lesions which were not neuroendocrine tumors. The overall sensitivity, specificity, and accuracy was therefore 93.3% (14 of 15), 80% (4 of 5), and 90.0% (18 of 20), respectively, in our patient population. Tc-HYNIC-TOC imaging provides reasonable accuracy in the evaluation pancreatic mass suspected to be neuroendocrine tumors.

  4. Biokinetics and dosimetric studies about 99mTc(V)-DMSA distribution.

    PubMed

    Correia, M B L; Magnata, S S L P; Silva, I M S; Catanho, M T J A; Lima, F F

    2010-05-10

    Research for radiodiagnostic agents should considerate biological critical parameters which will give own contribution on the absorbed dose. The dimercaptosuccinic acid (DMSA) labeled with (99m)Tc(V) is a radiopharmaceutical which has well established role in medullar thyroid carcinoma and has been proposed in evaluation of bone metastasis. This work studied the biokinetics and dosimetry of (99m)Tc(V)-DMSA by animal model. The (99m)Tc(V)-DMSA was prepared from a (III)DMSA kit alkalized. Mice (n=5) received (99m)Tc(V)DMSA i.v., they were sacrificed (30 min, 1h, 5h and 12h), the organs excised and the activities measured by a gamma counter. The results were evaluated based on %activity/g and the absorbed dose was estimated (MIRDOSE 3.0 program) by extrapolation of data from animal to human scale. The results showed the majority of organs reached the top uptake at 30 min, the greatest kidney uptake was (4.81 +/- 1.38)% activity/g, while the bone presented its highest uptake at 1h (5.49+/- 0.47)% activity/g, after 1h all the organs had activity exponential decrease. The biokinetic profile of (99m)Tc(V)-DMSA was well established, allowing quantifying of residence time, and the radiation dose estimates were made for this agent. About the absorbed dose, the preliminary results showed higher value to bone, being the soft tissue dose relatively low.

  5. Adsorption of (99m)Tc-radiopharmaceuticals onto injection vials and syringes.

    PubMed

    Mushtaq, Ahmad; Ur Rehman, Taj; Safdar Mansur, Muhammad; Jehangir, Mustanser

    2008-06-01

    Many groups have reported the adsorption or retention of (99m)Tc-radiopharmaceuticals on injection vials and disposable plastic syringes. Such an enormously high loss of radioactivity would result in poor images, radiation exposure, waste, and economic burdens. We therefore decided to investigate the extent of adsorption or retention of several (99m)Tc-radiopharmaceuticals on injection vials, rubber stoppers, and plastic syringes. These radiopharmaceuticals are produced as lyophilized kits in our department and supplied to various hospitals practicing nuclear medicine in Pakistan. A vial containing lyophilized material was reconstituted with 3 mL of freshly eluted Na(99m)TcO(4). A 1-mL aliquot of the resulting solution was withdrawn into a syringe at 0.25, 0.5, 1, 3, and 5 h after preparation. All preparations were stored at room temperature ( approximately 22 degrees C). After each withdrawal, the vial was reweighed and the activity remaining in the vial was measured using a radioisotope calibrator. The sample was reinjected into the vial. From the original weight and activity of solution in the vial, the initial activity per gram was calculated. From the weight and activity remaining in the vial after withdrawal of the sample, the activity per gram of the sample was calculated. From the difference between the initial activity per gram and the activity per gram of the sample, the percentage of (99m)Tc adsorbed on the vial was calculated. All preparations were kept in the syringe for 15 min, and the activity was measured before and after the syringe was emptied. The needle and plunger of the syringe were separated, and activity in the needle and plunger was also measured. The labeling efficiency of all radiopharmaceuticals used during these studies was more than 95%. In most cases, the activity of (99m)Tc found on the rubber stopper was less than 1%. Adsorption of (99m)Tc onto vials increased gradually with storage time. Adsorption was minimal at the initial stages

  6. Understanding the in vivo uptake kinetics of a phosphatidylethanolamine-binding agent (99m)Tc-Duramycin.

    PubMed

    Audi, Said; Li, Zhixin; Capacete, Joseph; Liu, Yu; Fang, Wei; Shu, Laura G; Zhao, Ming

    2012-08-01

    (99m)Tc-Duramycin is a peptide-based molecular probe that binds specifically to phosphatidylethanolamine (PE). The goal was to characterize the kinetics of molecular interactions between (99m)Tc-Duramycin and the target tissue. High level of accessible PE is induced in cardiac tissues by myocardial ischemia (30 min) and reperfusion (120 min) in Sprague-Dawley rats. Target binding and biodistribution of (99m)Tc-duramycin were captured using SPECT/CT. To quantify the binding kinetics, the presence of radioactivity in ischemic versus normal cardiac tissues was measured by gamma counting at 3, 10, 20, 60 and 180 min after injection. A partially inactivated form of (99m)Tc-Duramycin was analyzed in the same fashion. A compartment model was developed to quantify the uptake kinetics of (99m)Tc-Duramycin in normal and ischemic myocardial tissue. (99m)Tc-duramycin binds avidly to the damaged tissue with a high target-to-background radio. Compartment modeling shows that accessibility of binding sites in myocardial tissue to (99m)Tc-Duramycin is not a limiting factor and the rate constant of target binding in the target tissue is at 2.2 ml/nmol/min/g. The number of available binding sites for (99m)Tc-Duramycin in ischemic myocardium was estimated at 0.14 nmol/g. Covalent modification of D15 resulted in a 9-fold reduction in binding affinity. (99m)Tc-Duramycin accumulates avidly in target tissues in a PE-dependent fashion. Model results reflect an efficient uptake mechanism, consistent with the low molecular weight of the radiopharmaceutical and the relatively high density of available binding sites. These data help better define the imaging utilities of (99m)Tc-Duramycin as a novel PE-binding agent. Copyright © 2012 Elsevier Inc. All rights reserved.

  7. Understanding the in vivo uptake kinetics of a phosphatidylethanolamine-binding agent 99mTc-Duramycin

    PubMed Central

    Audi, Said; Li, Zhixin; Capacete, Joseph; Liu, Yu; Fang, Wei; Shu, Laura G.; Zhao, Ming

    2013-01-01

    Introduction 99mTc-Duramycin is a peptide-based molecular probe that binds specifically to phosphatidylethanolamine (PE). The goal was to characterize the kinetics of molecular interactions between 99mTc-Duramycin and the target tissue. Methods High level of accessible PE is induced in cardiac tissues by myocardial ischemia (30 min) and reperfusion (120 min) in Sprague Dawley rats. Target binding and biodistribution of 99mTc-duramycin was captured using SPECT/CT. To quantify the binding kinetics, the presence of radioactivity in ischemic versus normal cardiac tissues was measured by gamma counting at 3, 10, 20, 60 and 180 min after injection. A partially inactivated form of 99mTc-Duramycin was analyzed in the same fashion. A compartment model was developed to quantify the uptake kinetics of 99mTc-Duramycin in normal and ischemic myocardial tissue. Results 99mTc-duramycin binds avidly to the damaged tissue with a high target-to-background radio. Compartment modeling shows that accessibility of binding sites in myocardial tissue to 99mTc-Duramycin is not a limiting factor and the rate constant of target binding in the target tissue is at 2.2 ml/nmol/min/g. The number of available binding sites for 99mTc-Duramycin in ischemic myocardium was estimated at 0.14 nmol/g. Covalent modification of D15 resulted in a 9 fold reduction in binding affinity. Conclusion 99mTc-Duramycin accumulates avidly in target tissues in a PE-dependent fashion. Model results reflect an efficient uptake mechanism, consistent with the low molecular weight of the radiopharmaceutical and the relatively high density of available binding sites. These data help better define the imaging utilities of 99mTc-Duramycin as a novel PE-binding agent. PMID:22534031

  8. 78 FR 40824 - Proposed Collection; Comment Request for Form 8038-TC

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-08

    ... 8038-TC AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Notice and request for comments... Form 8038-TC, Information Return for Tax Credit Bonds. DATES: Written comments should be received on or...-TC. Abstract: Form 8038-TC will be used by issuers of qualified tax- exempt credit bonds, including...

  9. Induction magnetometer using a high-Tc superconductor coil

    NASA Astrophysics Data System (ADS)

    Sasada, Ichiro

    2010-05-01

    An induction magnetometer consisting of a search coil and an inverting operational amplifier is simple in structure and in signal transferring mechanism from the magnetic field input to the voltage output. Because this magnetometer is based on Faraday's law of induction, it has a lower cutoff frequency r/(2πL), where r is the resistance of the coil and L is its inductance. An attempt has been made to lower the cutoff frequency of the induction magnetometer by using a high-Tc superconductor coil. With a pancake coil (inner diameter ≈18 cm and outer diameter ≈23 cm, 92 turns, 3.23 mH) made of a Bismuth strontium calcium copper oxide (BSCCO) superconductor tape of 5 mm in width and 0.23 mm in thickness, the cutoff frequency achieved was 1.7 Hz which is much lower than that obtained with a bulky copper search coil which is typically in the range of 10-20 Hz. In the experiment, an inverting amplifier was made with a complementary metal-oxide semiconductor operational amplifier and was immersed in liquid nitrogen together with a BSCCO high-Tc superconducting coil. Discussion is made on the resolution of the induction magnetometer using a high-Tc superconductor search coil.

  10. High Tc bolometer developments for planetary missions

    NASA Technical Reports Server (NTRS)

    Brasunas, J.; Lakew, B.

    1991-01-01

    A simple polishing technique was developed for thinning the LaAlO3 substrates for high-quality Tc bolometer films, and thus reducing their heat capacity. A 150-ms bolometer was made on a LaAlO3 substrate with a 5-Hz D* value of 1.5 x 10 exp 8. It is shown that passive temperature stabilization is adequate for operation at the transition. There remained excess noise at the transition, but this noise appears to be of nonbolometric origin.

  11. Efficacy of (99m)Tc-EDDA/HYNIC-TOC SPECT/CT scintigraphy in Graves' ophthalmopathy.

    PubMed

    Zhao, Rong; Wang, Jiang; Deng, Jinglan; Yang, Weidong; Wang, Jing

    2012-01-01

    The aim of this study was to investigate the predictive role of the orbital somatostatin receptor scintigraphy with (99m)Tc-EDDA/HYNIC-TOC ((99m)Tc-TOC) to detect clinical stage of Graves' ophthalmopathy and the response to corticosteroid therapy. The subjects of the experiment were 46 patients with Graves' ophthalmopathy (GO) and four volunteers without eye disease or GO as the normal group (NG). Single photon emission computed tomography (SPECT), computed tomography (CT) and the left and right lateral position planar imaging of the heads of the all subjects were obtained 4 h after the intravenous injection of 555 MBq of (99m)Tc-TOC. The (99m)Tc-TOC SPECT/CT was repeated 3 months later. 35 (35/46) patients were received corticosteroid therapy (prednisolone, 10 mg po tid ) for 3 months, however, the other 11 patients as control groups did not receive any treatment. The treatment effect was evaluated both by the orbital (99m)Tc-TOC uptake and NOSPECS. A significant decrease in the O/OC ratio was observed in 22 GO patients between pre- and post-treatment (1.64 ± 0.13 vs. 1.21 ± 0.09, P < 0.05). There were neither significant difference of the O/OC ratio in 13 GO patients between pre- and post-treatment periods, nor significant difference in the 9 (9/11) patients before and after three months. Orbital (99m)Tc-TOC scintigraphy is a feasible technique to estimate the Graves' ophthalmopathy activity and predict the response to subsequent corticosteroid therapy in GO patients. The technique could be a useful tool for physicians not familiar with CAS determination.

  12. Efficacy of 99mTc-EDDA/HYNIC-TOC SPECT/CT scintigraphy in Graves’ ophthalmopathy

    PubMed Central

    Zhao, Rong; Wang, Jiang; Deng, Jinglan; Yang, Weidong; Wang, Jing

    2012-01-01

    The aim of this study was to investigate the predictive role of the orbital somatostatin receptor scintigraphy with 99mTc-EDDA/HYNIC-TOC (99mTc-TOC) to detect clinical stage of Graves’ ophthalmopathy and the response to corticosteroid therapy. The subjects of the experiment were 46 patients with Graves’ ophthalmopathy (GO) and four volunteers without eye disease or GO as the normal group (NG). Single photon emission computed tomography (SPECT), computed tomography (CT) and the left and right lateral position planar imaging of the heads of the all subjects were obtained 4 h after the intravenous injection of 555 MBq of 99mTc-TOC. The 99mTc-TOC SPECT/CT was repeated 3 months later. 35 (35/46) patients were received corticosteroid therapy (prednisolone, 10 mg po tid ) for 3 months, however, the other 11 patients as control groups did not receive any treatment. The treatment effect was evaluated both by the orbital 99mTc-TOC uptake and NOSPECS. A significant decrease in the O/OC ratio was observed in 22 GO patients between pre- and post-treatment (1.64 ± 0.13 vs. 1.21 ± 0.09, P < 0.05). There were neither significant difference of the O/OC ratio in 13 GO patients between pre- and post-treatment periods, nor significant difference in the 9 (9/11) patients before and after three months. Orbital 99mTc-TOC scintigraphy is a feasible technique to estimate the Graves’ ophthalmopathy activity and predict the response to subsequent corticosteroid therapy in GO patients. The technique could be a useful tool for physicians not familiar with CAS determination. PMID:23133815

  13. Synthesis of 99mTc-nimotuzumab with tricarbonyl ion: in vitro and in vivo studies.

    PubMed

    Garcia, Maria Fernanda; Camacho, Ximena; Calzada, Victoria; Fernandez, Marcelo; Porcal, Williams; Alonso, Omar; Gambini, Juan Pablo; Cabral, Pablo

    2012-01-01

    The Epidermal growth factor receptor (EGFR) family plays an important role in carcinogenesis. CIMAher® (Nimotuzumab), is a humanized monoclonal antibody, which recognizes EGFR with high affinity. The aim of this work was to perform the direct labeling of Nimotuzumab with [99mTc(CO)3(H2O)3]+ as precursor and to evaluate its labeling conditions, in vitro and in vivo stability and biodistrution in normal C57 BL/6J mice. 99mTc(CO3)-Nimotuzumab labeling yields were up to 90%. More than 90% of the complex remained intact after 24 h of incubation with L-Histidine (1/300 molar ratio). Biodistribution studies in normal mice were also performed. Inmunoreactivity was confirmed by cell binding assays with A431cells. These results encourage the evaluation of the potential role of 99mTc(CO)3-Nimotuzumab as a novel tumor-avid radiotracer for targeting in vivo EGFR expression.

  14. Tc-99m Glu-Cys-Gly-His-Gly-Lys (ECG-HGK), a novel Tc-99m labeled hexapeptide for molecular tumor imaging.

    PubMed

    Kim, Dae-Weung; Kim, Myoung Hyoun; Kim, Chang Guhn

    2016-03-01

    Domain 5 of kinin-free high molecular weight kininogen inhibits the adhesion of many tumor cell lines, and it has been reported that the histidine-glycine-lysine (HGK)-rich region might be responsible for inhibition of cell adhesion. The authors developed HGK-containing hexapeptide, glutamic acid-cysteine-glycine (ECG)-HGK, and evaluated the utility of Tc-99m ECG-HGK for tumor imaging. Hexapeptide, ECG-HGK was synthesized using Fmoc solid-phase peptide synthesis. Radiolabeling efficiency was evaluated. The uptake of Tc-99m ECG-HGK within HT-1080 cells was evaluated in vitro. In HT-1080 tumor-bearing mice, gamma imaging and biodistribution studies were performed. The complexes Tc-99m ECG-HGK was prepared in high yield. The uptake of Tc-99m ECG-HGK within the HT-1080 tumor cells had been demonstrated by in vitro studies. The gamma camera imaging in the murine model showed that Tc-99m ECG-HGK was accumulated substantially in the HT-1080 tumor (tumor-to-muscle ratio = 5.7 ± 1.4 at 4 h), and the tumoral uptake was blocked by the co-injection of excess HGK (tumor-to-muscle ratio = 2.8 ± 0.6 at 4 h). In the present study, Tc-99m ECG-HGK was developed as a new tumor imaging agents. Our in vitro and in vivo studies revealed specific function of Tc-99m ECG-HGK for tumor imaging. Copyright © 2016 John Wiley & Sons, Ltd.

  15. Effectiveness of TC-325 (Hemospray) for treatment of diffuse or refractory upper gastrointestinal bleeding - a single center experience.

    PubMed

    Cahyadi, Oscar; Bauder, Markus; Meier, Benjamin; Caca, Karel; Schmidt, Arthur

    2017-11-01

    TC-325 (Hemospray, Cook Medical) is a powder agent for endoscopic hemostasis in patients with upper gastrointestinal bleeding (UGIB). Although most publications are based on case-reports and retrospective studies, data on efficacy are promising. Here we report our experience with TC-325 for diffuse or refractory UGIB.  Data on patients receiving TC-325 for endoscopic hemostasis from November 2013 to February 2017 at our center were analyzed retrospectively. Primary endpoints were technical success (successful immediate hemostasis) and clinical success (effective hemostasis and no recurrent bleeding). Secondary endpoints were recurrent bleeding within 3 and 7 days, hospital mortality and TC-325 associated complications. TC-325 was used for bleeding not amenable to standard endoscopic treatment (e. g. diffuse bleeding) or as salvage therapy after failure of conventional methods.  Fifty-two patients received TC-325 treatment. Most of the patients were treated for peptic ulcer bleeding (18/52 patients, 34.6 %) and post-interventional bleeding (13/52 patients, 25 %). Hemospray was used in 23/52 (44.2 %) patients as monotherapy and in 29/52 (55.8 %) patients as a salvage therapy. Application of the powder on the bleeding source was successful in all patients with no therapy-related adverse events (AEs). Immediate hemostasis was achieved in 51/52 (98.1 %) patients. Recurrent bleeding within 3 and 7 days was observed in 22/51 and 25/51 patients respectively (43.1 % and 49 %). The overall clinical success was 56.9 % on day 3 and 51 % on day 7. Total mortality was 15.4 % (8 patients), bleeding associated mortality was 3.8 % (2 patients). There were no therapy-related AEs.  TC-325 showed a high technical success rate as monotherapy for bleeding sources not amenable to standard methods or as an "add-on" therapy after unsuccessful hemostasis. However, rebleeding was frequent in this cohort and further studies are warranted to exactly define a

  16. PREFACE: 2013 Joint IMEKO (International Measurement Confederation) TC1-TC7-TC13 Symposium: Measurement Across Physical and Behavioural Sciences

    NASA Astrophysics Data System (ADS)

    Battista Rossi, Giovanni; Crenna, Francesco; Belotti, Vittorio

    2013-09-01

    The 2013 Joint IMEKO (International Measurement Confederation) TC1-C7-TC13 was organised by the University of Genova - DIME/MEC, Measurement Laboratory, Italy, on 4-6 September 2013. The work of this symposium is reported in this volume. The scope of the symposium includes the main topics covered by the above Technical Committees: TC1 Education and Training in Measurement and Instrumentation TC7 Measurement Science TC13 Measurements in Biology and Medicine This is in keeping with the tradition set by the previous events of this well established series. There has been a special focus on measurement across physical and behavioural sciences, with the aim of highlighting the interdisciplinary character of measurement science and of promoting constructive interactions with scientists in other disciplines. The discussion was introduced by keynote lectures on measurement challenges in psychophysics, psychometrics and quantum physics. The symposium was attended by experts working in these areas from 18 countries, including USA, Australia and Japan, and provided a useful forum for them to share and exchange their work and ideas. In total over sixty papers are included in the volume, organised according to the presentation sessions. Each paper was independently peer-reviewed by two reviewers from a distinguished international panel. The Symposium was held in Genova, which was the European Capital of Culture in 2004, and took place in Palazzo Ducale, an important historical building whose construction started in the 13th century, and that has been the house of the Duke of Genova from the 14th century. Genova, whose name comes from the Latin word 'Janua' (meaning 'door', as January is the door month of the year), has been regarded over the centuries as a door connecting Europe with the different countries and cultures of the Mediterranean basin and thus was an appropriate site for an international symposium involving different and new scientific visions and approaches to

  17. SCDFT Study of High Tc Nitride Superconductors

    NASA Astrophysics Data System (ADS)

    Arita, R.

    Based on the density functional theory for superconductors (SCDFT), we study the pairing mechanism of the layered nitride superconductors, β-LixMNCl (M=Zr, Hf). Recently, it has been shown that SCDFT reproduces experimental superconducting transition temperatures (Tc) of conventional superconductors very accurately. Here we use SCDFT as a "litmus paper" to determine whether the system is a conventional or unconventional superconductor. We show that Tc estimated by SCDFT is less than half of the experimental Tc and its doping dependence is opposite to that observed in the experiments. The present result suggests that β- LixMNCl is not a Migdal-Eliashberg type superconductor.

  18. Enhanced inhibitory synaptic transmission in the spinal dorsal horn mediates antinociceptive effects of TC-2559

    PubMed Central

    2011-01-01

    Background TC-2559 is a selective α4β2 subtype of nicotinic acetylcholine receptor (nAChR) partial agonist and α4β2 nAChR activation has been related to antinociception. The aim of this study is to investigate the analgesic effect of TC-2559 and its underlying spinal mechanisms. Results 1) In vivo bioavailability study: TC-2559 (3 mg/kg) had high absorption rate in rats with maximal total brain concentration reached over 4.6 μM within first 15 min after administration and eliminated rapidly with brain half life of about 20 min after injection. 2) In vivo behavioral experiments: TC-2559 exerts dose dependent antinociceptive effects in both formalin test in mice and chronic constriction injury (CCI) model in rats by activation of α4β2 nAChRs; 3) Whole-cell patch-clamp studies in the superficial dorsal horn neurons of the spinal cord slices: perfusion of TC-2559 (2 μM) significantly increased the frequency, but not amplitude of spontaneous inhibitory postsynaptic currents (sIPSCs). The enhancement of sIPSCs was blocked by pre-application of DHβE (2 μM), a selective α4β2 nicotinic receptor antagonist. Neither the frequency nor the amplitude of spontaneous excitatory postsynaptic currents (sEPSCs) of spinal dorsal horn neurons were affected by TC-2559. Conclusions Enhancement of inhibitory synaptic transmission in the spinal dorsal horn via activation of α4β2 nAChRs may be one of the mechanisms of the antinociceptive effects of TC-2559 on pathological pain models. It provides further evidence to support the notion that selective α4β2 subtype nAChR agonist may be developed as new analgesic drug for the treatment of neuropathic pain. PMID:21816108

  19. Preclinical evaluation of a new, stabilized neurotensin(8--13) pseudopeptide radiolabeled with (99m)tc.

    PubMed

    García-Garayoa, Elisa; Bläuenstein, Peter; Bruehlmeier, Matthias; Blanc, Alain; Iterbeke, Koen; Conrath, Peter; Tourwé, Dirk; Schubiger, P August

    2002-03-01

    The rapid degradation of neurotensin (NT) limits its clinical use in cancer imaging and therapy. Thus, a new NT(8--13) pseudopeptide, NT-VIII, was synthesized. Some changes were introduced in the sequence of NT(8--13) to stabilize the molecule against enzymatic degradation: Arg(8) was N-methylated, and Lys and Tle replaced Arg(9) and Ile(12), respectively. Finally, (NalphaHis)Ac was coupled to the N-terminus for (99m)Tc(CO)(3) labeling. This peptide was characterized both in vitro and in vivo. The new analog was labeled with (99m)Tc(CO)(3). Its metabolic stability was analyzed both in human plasma and in HT-29 cells. Binding properties, receptor downregulation, and internalization were tested with HT-29 cells. Biodistribution was evaluated in nude mice with HT-29 xenografts. (99m)Tc(CO)(3)NT-VIII showed a high stability in plasma, where most of the peptide remained intact after 24 h of incubation at 37 degreesC. However, the degradation in HT-29 cells was more rapid (46% of intact (99m)Tc(CO)(3)NT-VIII after 24 h at 37 degreesC). Binding to NT1 receptors (NTR1) was saturable and specific. Scatchard analysis showed a high affinity for (99m)Tc(CO)(3)NT-VIII, with a dissociation constant similar to (125)I-NT (1.8 vs. 1.6 nmol/L). After interacting with NTR1, (99m)Tc(CO)(3)NT-VIII was rapidly internalized, with more than 90% internalized after 30 min. It also distributed and cleared rapidly in nude mice bearing HT-29 xenografts. The highest rates of accumulation were found in kidney and tumor at all time points tested. Tumor uptake was highly specific because it could be blocked by coinjection with a high dose of (NalphaHis)Ac-NT(8--13). Tumors were clearly visualized in scintigraphy images. The changes that were introduced stabilized the molecule against enzymatic degradation without affecting binding properties. Moreover, the increase in stability enhanced tumor uptake, making this derivative a promising candidate for clinical use.

  20. TcCYPR04, a Cacao Papain-Like Cysteine-Protease Detected in Senescent and Necrotic Tissues Interacts with a Cystatin TcCYS4

    PubMed Central

    Cardoso, Thyago Hermylly Santana; Freitas, Ana Camila Oliveira; Andrade, Bruno Silva; de Sousa, Aurizangela Oliveira; Santiago, André da Silva; Koop, Daniela Martins; Gramacho, Karina Peres; Alvim, Fátima Cerqueira; Micheli, Fabienne; Pirovani, Carlos Priminho

    2015-01-01

    The interaction amongst papain-like cysteine-proteases (PLCP) and their substrates and inhibitors, such as cystatins, can be perceived as part of the molecular battlefield in plant-pathogen interaction. In cacao, four cystatins were identified and characterized by our group. We identified 448 proteases in cacao genome, whereof 134 were cysteine-proteases. We expressed in Escherichia coli a PLCP from cacao, named TcCYSPR04. Immunoblottings with anti-TcCYSPR04 exhibited protein increases during leaf development. Additional isoforms of TcCYSPR04 appeared in senescent leaves and cacao tissues infected by Moniliophthora perniciosa during the transition from the biotrophic to the saprophytic phase. TcCYSPR04 was induced in the apoplastic fluid of Catongo and TSH1188 cacao genotypes, susceptible and resistant to M. perniciosa, respectively, but greater intensity and additional isoforms were observed in TSH1188. The fungal protein MpNEP induced PLCP isoform expression in tobacco leaves, according to the cross reaction with anti-TcCYSPR04. Several protein isoforms were detected at 72 hours after treatment with MpNEP. We captured an active PLCP from cacao tissues, using a recombinant cacao cystatin immobilized in CNBr-Sepharose. Mass spectrometry showed that this protein corresponds to TcCYSPR04. A homology modeling was obtained for both proteins. In order to become active, TcCYSPR04 needs to lose its inhibitory domain. Molecular docking showed the physical-chemical complementarities of the interaction between the cacao enzyme and its inhibitor. We propose that TcCYSPR04 and its interactions with cacao cystatins are involved in the senescence and necrosis events related to witches’ broom symptoms. This molecular interaction may be the target for future interventions to control witches' broom disease. PMID:26641247

  1. TcCYPR04, a Cacao Papain-Like Cysteine-Protease Detected in Senescent and Necrotic Tissues Interacts with a Cystatin TcCYS4.

    PubMed

    Cardoso, Thyago Hermylly Santana; Freitas, Ana Camila Oliveira; Andrade, Bruno Silva; Sousa, Aurizangela Oliveira de; Santiago, André da Silva; Koop, Daniela Martins; Gramacho, Karina Peres; Alvim, Fátima Cerqueira; Micheli, Fabienne; Pirovani, Carlos Priminho

    2015-01-01

    The interaction amongst papain-like cysteine-proteases (PLCP) and their substrates and inhibitors, such as cystatins, can be perceived as part of the molecular battlefield in plant-pathogen interaction. In cacao, four cystatins were identified and characterized by our group. We identified 448 proteases in cacao genome, whereof 134 were cysteine-proteases. We expressed in Escherichia coli a PLCP from cacao, named TcCYSPR04. Immunoblottings with anti-TcCYSPR04 exhibited protein increases during leaf development. Additional isoforms of TcCYSPR04 appeared in senescent leaves and cacao tissues infected by Moniliophthora perniciosa during the transition from the biotrophic to the saprophytic phase. TcCYSPR04 was induced in the apoplastic fluid of Catongo and TSH1188 cacao genotypes, susceptible and resistant to M. perniciosa, respectively, but greater intensity and additional isoforms were observed in TSH1188. The fungal protein MpNEP induced PLCP isoform expression in tobacco leaves, according to the cross reaction with anti-TcCYSPR04. Several protein isoforms were detected at 72 hours after treatment with MpNEP. We captured an active PLCP from cacao tissues, using a recombinant cacao cystatin immobilized in CNBr-Sepharose. Mass spectrometry showed that this protein corresponds to TcCYSPR04. A homology modeling was obtained for both proteins. In order to become active, TcCYSPR04 needs to lose its inhibitory domain. Molecular docking showed the physical-chemical complementarities of the interaction between the cacao enzyme and its inhibitor. We propose that TcCYSPR04 and its interactions with cacao cystatins are involved in the senescence and necrosis events related to witches' broom symptoms. This molecular interaction may be the target for future interventions to control witches' broom disease.

  2. Expression of an endoglucanase from Tribolium castaneum (TcEG1) in Saccharomyces cerevisiae.

    PubMed

    Shirley, Derek; Oppert, Cris; Reynolds, Todd B; Miracle, Bethany; Oppert, Brenda; Klingeman, William E; Jurat-Fuentes, Juan Luis

    2014-10-01

    Insects are a largely unexploited resource in prospecting for novel cellulolytic enzymes to improve the production of ethanol fuel from lignocellulosic biomass. The cost of lignocellulosic ethanol production is expected to decrease by the combination of cellulose degradation (saccharification) and fermentation of the resulting glucose to ethanol in a single process, catalyzed by the yeast Saccharomyces cerevisiae transformed to express efficient cellulases. While S. cerevisiae is an established heterologous expression system, there are no available data on the functional expression of insect cellulolytic enzymes for this species. To address this knowledge gap, S. cerevisiae was transformed to express the full-length cDNA encoding an endoglucanase from the red flour beetle, Tribolium castaneum (TcEG1), and evaluated the activity of the transgenic product (rTcEG1). Expression of the TcEG1 cDNA in S. cerevisiae was under control of the strong glyceraldehyde-3 phosphate dehydrogenase promoter. Cultured transformed yeast secreted rTcEG1 protein as a functional β-1,4-endoglucanase, which allowed transformants to survive on selective media containing cellulose as the only available carbon source. Evaluation of substrate specificity for secreted rTcEG1 demonstrated endoglucanase activity, although some activity was also detected against complex cellulose substrates. Potentially relevant to uses in biofuel production rTcEG1 activity increased with pH conditions, with the highest activity detected at pH 12. Our results demonstrate the potential for functional production of an insect cellulase in S. cerevisiae and confirm the stability of rTcEG1 activity in strong alkaline environments. © 2013 Institute of Zoology, Chinese Academy of Sciences.

  3. Tuning of magnetic frustration in S = 1 / 2 Kagomé lattices {[Cu3(CO3)2(bpe)3](CLO4)2}n and {[Cu3(CO3)2(bpy)3](CLO4)2}n through rigid and flexible ligands

    NASA Astrophysics Data System (ADS)

    Ajeesh, M. O.; Yogi, A.; Padmanabhan, M.; Nath, R.

    2015-04-01

    Single crystalline and polycrystalline samples of S = 1 / 2 Kagomé lattices { [Cu3(CO3)2(bpe)3 ](CLO4)2 } n and { [Cu3(CO3)2(bpy)3 ](CLO4)2 } n, respectively were synthesized. Their structural and magnetic properties were characterized by means of x-ray diffraction and magnetization measurements. Both compounds crystalize in a hexagonal structure (space group P-6) consisting of CuO4 Kagomé layers in the ab-plane but linked along c direction through either rigid bpy or flexible bpe ligands to form 3D frame works. Magnetic measurements reveal that both the compounds undergo ferromagnetic ordering (TC) at low temperatures and the TC and the extent of frustration could be tuned by changing the nature of the pillar ligands. {[Cu3(CO3)2(bpe)3](CLO4)2}n which is made up of flexible bpe ligands has a TC of 5.7 K and a Curie-Weiss temperature (θCW) of -39.7 K giving rise to a frustration parameter of |θCW | /TC ≃ 6.96. But the replacement of bpe by a more rigid and electronically delocalized bpy ligand leads to an enhanced TC ≃ 9.3 K and a reduced frustration parameter of |θCW | /TC3.54.

  4. The Endothelial Nitric Oxide Synthase (NOS3–786T>C) Genetic Polymorphism in Chronic Heart Failure: Effects of Mutant -786C allele on Long-term Mortality

    PubMed Central

    Terzi, Sait; Emre, Ayşe; Yesilcimen, Kemal; Yazıcı, Selçuk; Erdem, Aysun; Sadik Ceylan, Ufuk; Ciloglu, Figen

    2017-01-01

    Background Nitric oxide plays an important role in the regulation of basal vascular tone and cardiac myocyte function. We investigated the NOS3–786T>C polymorphism in chronic heart failure (CHF) and its effects on long-term mortality. Methods Ninety-one patients with CHF who were referred to the Department of Cardiology of Siyami Ersek Cardiovascular and Thoracic Surgery Center for cardiopulmonary exercise testing between April 2001 and January 2004 and 30 controls were enrolled in this study. Patient were followed prospectively for a period of 1 to 12 years. Results Patients and controls were divided into three groups: TT, TC and CC, according to their NOS3–786T>C polymorphism. We noted that there was no significant difference in the genotype distribution between patients and controls. There was also no significant difference in endothelial nitric oxide synthase (eNOS) gene polymorphism between ischemic HF and nonischemic HF. During the follow-up period, 61 (67%) deaths occurred. The nonsurvivor group had lower left ventricular ejection fraction (LVEF) (p = 0.01), reduced peak oxygen consumption (p = 0.04) and were of older age (p = 0.001). Age, LVEF, peak oxygen consumption and genotype were found to be predictors of mortality (p < 0.05). Additionally, mortality was significantly increased in -786CC genotype patients compared to TT genotype patients (hazard ratio = 2.2; p = 0.03). By multivariate analysis, age and eNOS genotype were determined to be significant independent predictors of death. Additionally, Kaplan-Meier analysis confirmed that homozygote -786C genotype was associated with an increased risk of death (χ2 = 4.6, p = 0.03). Conclusions Our findings showed that the NOS3–786T>C polymorphism was associated with an increased risk of mortality in patients with CHF. PMID:29033513

  5. Validation of an ergonomic method to withdraw [99mTc] radiopharmaceuticals.

    PubMed

    Blondeel-Gomes, Sandy; Marie, Solène; Fouque, Julien; Loyeau, Sabrina; Madar, Olivier; Lokiec, François

    2017-11-10

    The main objective of the present work was to ensure quality of radiopharmaceuticals syringes withdrawn with a "Spinal needle/obturator In-Stopper" system. Methods: Visual examinations and physicochemical tests are performed at T0 and T+4h for [ 99m Tc]albumin nanocolloid and T+7h for [ 99m Tc]eluate, [ 99m Tc] HydroxyMethylene DiPhosphonate and [ 99m Tc]Human Serum Albumin. Microbiological validation was performed according to European pharmacopoeia. Fingertip radiation exposure was evaluated to confirm the safety of the system. Results: Results show stable visual and physicochemical properties. The integrity of the connector was not affected after 30 punctures (no cores). No microbiological contamination was found on tested syringes. Conclusion: The system could be used 30 times. The stability of syringes drawing with this method is guaranteed up to 4 hours for [ 99m Tc]albumin nanocolloid and 7 hours for [ 99m Tc]eluate, [ 99m Tc]HydroxyMethylene DisPhosphonate and [ 99m Tc]Human serum albumin. Copyright © 2017 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  6. Comparison of 99mTc-UBI 29-41, 99mTc-Ciprofloxacin, 99mTc-Ciprofloxacin dithiocarbamate and 111In-biotin for targeting experimental Staphylococcus aureus and Escherichia coli foreign-body infections: an ex-vivo study.

    PubMed

    Auletta, Sveva; Baldoni, Daniela; Varani, Michela; Galli, Filippo; Hajar, Iman A; Duatti, Adriano; Ferro-Flores, Guillermina; Trampuz, Andrej; Signore, Alberto

    2017-08-28

    Diagnosis of implant-associated infection is challenging. Several radiopharmaceuticals have been described but direct comparisons are limited. Here we compared in vitro and in an animal model 99mTc-UBI, 99mTc-Ciprofloxacin, 99mTcN-CiproCS2 and 111In-DTPA-biotin for targeting E. coli (ATCC 25922) and S. aureus (ATCC 43335). Stability controls were performed with the labelled radiopharmaceuticals during 6 h in saline and serum. The in vitro binding to viable or killed bacteria was evaluated at 37 °C and 4 °C. For in vivo studies, Teflon cages were subcutaneously implanted in mice, followed by percutaneous infection. Biodistribution of i.v. injected radiolabelled radiopharmaceuticals were evaluated during 24 h in cages and dissected tissues. Labelling efficiency of all radiopharmaceuticals ranged between 94% and 98%, with high stability both in saline and in human serum. In vitro binding assays displayed a rapid but poor bacterial binding for all tested agents. Similar binding kinetic occurred also with heat-killed and ethanol-killed bacteria. In the tissue cage model, infection was detected at different time points: 99mTc-UBI and 99mTcN-CiproCS2 showed higher infected cage/sterile cage ratio at 24 h for both E. coli and S. aureus; 99mTc-Ciprofloxacin at 24 h for both E. coli and at 4 h for S. aureus; 111In-DTPA-biotin accumulates faster in both E. coli and S. aureus infected cages. 99mTc-UBI, 99mTcN-CiproCS2 showed poor in vitro binding but good in vivo binding to E. coli only. 111In-DTPA-biotin showed poor in vitro binding but good in vivo binding to S. aureus and poor to E. coli. 99mTc-Ciprofloxacin showed poor in vitro binding but good in vivo binding to all tested bacteria. The mechanism of accumulation in infected sites remains to be elucidated.

  7. Detection of atherosclerotic plaques in ApoE-deficient mice using (99m)Tc-duramycin.

    PubMed

    Liu, Zhonglin; Larsen, Brandon T; Lerman, Lilach O; Gray, Brian D; Barber, Christy; Hedayat, Ahmad F; Zhao, Ming; Furenlid, Lars R; Pak, Koon Y; Woolfenden, James M

    2016-08-01

    Apoptosis of macrophages and smooth muscle cells is linked to atherosclerotic plaque destabilization. The apoptotic cascade leads to exposure of phosphatidylethanolamine (PE) on the outer leaflet of the cell membrane, thereby making apoptosis detectable using probes targeting PE. The objective of this study was to exploit capabilities of a PE-specific imaging probe, (99m)Tc-duramycin, in localizing atherosclerotic plaque and assessing plaque evolution in apolipoprotein-E knockout (ApoE(-/-)) mice. Atherosclerosis was induced in ApoE(-/-) mice by feeding an atherogenic diet. (99m)Tc-duramycin images were acquired using a small-animal SPECT imager. Six ApoE(-/-) mice at 20weeks of age (Group I) were imaged and then sacrificed for ex vivo analyses. Six additional ApoE(-/-) mice (Group II) were imaged at 20 and 40weeks of age before sacrifice. Six ApoE wild-type (ApoE(+/+)) mice (Group III) were imaged at 40weeks as controls. Five additional ApoE(-/-) mice (40weeks of age) (Group IV) were imaged with a (99m)Tc-labeled inactive peptide, (99m)Tc-LinDUR, to assess (99m)Tc-duramycin targeting specificity. Focal (99m)Tc-duramycin uptake in the ascending aorta and aortic arch was detected at 20 and 40weeks in the ApoE(-/-) mice but not in ApoE(+/+) mice. (99m)Tc-duramycin uptake in the aortic lesions increased 2.2-fold on quantitative imaging in the ApoE(-/-) mice between 20 and 40weeks. Autoradiographic and histological data indicated significantly increased (99m)Tc-duramycin uptake in the ascending aorta and aortic arch associated with advanced plaques. Quantitative autoradiography showed that the ratio of activity in the aortic arch to descending thoracic aorta, which had no plaques or radioactive uptake, was 2.1 times higher at 40weeks than at 20weeks (6.62±0.89 vs. 3.18±0.29, P<0.01). There was barely detectable focal uptake of (99m)Tc-duramycin in the aortic arch of ApoE(+/+) mice. No detectable (99m)Tc-LinDUR uptake was observed in the aortas of ApoE(-/-) mice. PE

  8. MagIC: Geomagnetic Applications from Earth History to Archeology

    NASA Astrophysics Data System (ADS)

    Constable, C.; Tauxe, L.; Koppers, A.; Minnett, R.; Jarboe, N.

    2016-12-01

    Major scientific challenges increasingly require an interdisciplinary approach, and highlight the need for open archives, incorporating visualization and analysis tools that are flexible enough to address novel research problems. Increasingly modern standards for publication are (or should be) demanding direct links to data, data citations, and adequate documentation that allow other researchers direct access to the fundamental measurements and analyses producing the results. Carefully documented metadata are essential and data models may need considerable complexity to accommodate re-use of observations originally collected with a different purpose in mind. The Magnetics Information Consortium (MagIC) provides an online home for all kinds of paleo-, archeo-magnetic, rock, and environmental magnetic data, from documentation of fieldwork, through lab protocols, to interpretations in terms of geomagnetic history. Examples of their application to understanding geomagnetic field behavior, archeological dating, and voyages of exploration to discover America will be used to highlight best practices and illustrate unexpected benefits of data archived using best practices with the goal of maintaining high standards for reproducibility.

  9. The different expression of TRPM7 and MagT1 impacts on the proliferation of colon carcinoma cells sensitive or resistant to doxorubicin.

    PubMed

    Cazzaniga, Alessandra; Moscheni, Claudia; Trapani, Valentina; Wolf, Federica I; Farruggia, Giovanna; Sargenti, Azzurra; Iotti, Stefano; Maier, Jeanette A M; Castiglioni, Sara

    2017-01-17

    The processes leading to anticancer drug resistance are not completely unraveled. To get insights into the underlying mechanisms, we compared colon carcinoma cells sensitive to doxorubicin with their resistant counterpart. We found that resistant cells are growth retarded, and show staminal and ultrastructural features profoundly different from sensitive cells. The resistant phenotype is accompanied by the upregulation of the magnesium transporter MagT1 and the downregulation of the ion channel kinase TRPM7. We demonstrate that the different amounts of TRPM7 and MagT1 account for the different proliferation rate of sensitive and resistant colon carcinoma cells. It remains to be verified whether they are also involved in the control of other "staminal" traits.

  10. Synthesis and characterization of high-Tc superconductors in the Tl-Ca-Ba-Cu-O system

    NASA Technical Reports Server (NTRS)

    Bansal, Narottam P.; Farrell, D. E.

    1989-01-01

    Both Tl2Ca2Ba2Cu3O10 and TlCa3BaCu3O8.5 are investigated for superconductivity as a function of the sintering temperature, time, atmosphere, and quench rate in an effort to synthesize the high-Tc superconducting phase in the thallium system. The samples are characterized by electrical resistivity measurements, X-ray diffraction, and scanning electron microscopy. Samples of starting composition Tl2Ca2Ba2Cu3O10 fired in air at 860-900 C and rapidly quenched show a Tc of 96-107 K. In contrast, specimens of starting composition TlCa3BaCu3O8.5 when baked at 900 C and slowly cooled in oxygen superconduct at 116 K and above and consist of Tl2Ca2Ba2Cu3O(10+x) as the dominant phase. The results also show that, in contrast to the case of YBa2Cu3O(7-x), doping with a small concentration of fluorine sharpens the resistive transition and produces a large Tc increase in thallium-based superconductors.

  11. [Contamination levels to room air arising from the use of 99mTc-gas and prevention from the contamination].

    PubMed

    Komatani, A; Akutsu, T; Yamaguchi, K; Onodera, Y; Manaka, Y; Takahashi, K

    1996-04-01

    99mTc-gas (TECHNEGAS) is a 99mTc-labeled micro-aerosol which is considered to have different behavior from 133Xe or 81mKr gas. In order to estimate contamination levels to room air arising from the use of 99mTc-gas, filtered expired air during administration and 1, 2, 3, 5, 10 min after the administration were collected in each polyethylene bag. Radioactivities of the polyethylene bags, used filter and the lung were measured with 3-head scintillation camera. The activity of the expired air diminished within 6-10 min and about 5% of whole discharged 99mTc-gas was released to room air. The activity of the used filter was two times of the lung. According to these results, it is recommended that the 99mTc-gas may be administrated in a exclusive room. The administrated patient and used filter must be remain in the exclusive room.

  12. The feasibility of imaging myocardial ischemic/reperfusion injury using (99m)Tc-labeled duramycin in a porcine model.

    PubMed

    Wang, Lei; Wang, Feng; Fang, Wei; Johnson, Steven E; Audi, Said; Zimmer, Michael; Holly, Thomas A; Lee, Daniel C; Zhu, Bao; Zhu, Haibo; Zhao, Ming

    2015-02-01

    When pathologically externalized, phosphatidylethanolamine (PE) is a potential surrogate marker for detecting tissue injuries. (99m)Tc-labeled duramycin is a peptide-based imaging agent that binds PE with high affinity and specificity. The goal of the current study was to investigate the clearance kinetics of (99m)Tc-labeled duramycin in a large animal model (normal pigs) and to assess its uptake in the heart using a pig model of myocardial ischemia-reperfusion injury. The clearance and distribution of intravenously injected (99m)Tc-duramycin were characterized in sham-operated animals (n=5). In a closed chest model of myocardial ischemia, coronary occlusion was induced by balloon angioplasty (n=9). (99m)Tc-duramycin (10-15mCi) was injected intravenously at 1hour after reperfusion. SPECT/CT was acquired at 1 and 3hours after injection. Cardiac tissues were analyzed for changes associated with acute cellular injuries. Autoradiography and gamma counting were used to determine radioactivity uptake. For the remaining animals, (99m)Tc-tetrafosamin scan was performed on the second day to identify the infarct site. Intravenously injected (99m)Tc-duramycin cleared from circulation predominantly via the renal/urinary tract with an α-phase half-life of 3.6±0.3minutes and β-phase half-life of 179.9±64.7minutes. In control animals, the ratios between normal heart and lung were 1.76±0.21, 1.66±0.22, 1.50±0.20 and 1.75±0.31 at 0.5, 1, 2 and 3hours post-injection, respectively. The ratios between normal heart and liver were 0.88±0.13, 0.80±0.13, 0.82±0.19 and 0.88±0.14. In vivo visualization of focal radioactivity uptake in the ischemic heart was attainable as early as 30min post-injection. The in vivo ischemic-to-normal uptake ratios were 3.57±0.74 and 3.69±0.91 at 1 and 3hours post-injection, respectively. Ischemic-to-lung ratios were 4.89±0.85 and 4.93±0.57; and ischemic-to-liver ratios were 2.05±0.30 to 3.23±0.78. The size of (99m)Tc-duramycin positive

  13. The feasibility of imaging myocardial ischemic/reperfusion injury using 99mTc-labeled duramycin in a porcine model

    PubMed Central

    Wang, Lei; Wang, Feng; Fang, Wei; Johnson, Steven E.; Audi, Said; Zimmer, Michael; Holly, Thomas A; Lee, Daniel; Zhu, Bao; Zhu, Haibo; Zhao, Ming

    2015-01-01

    When pathologically externalized, phosphatidylethanolamine (PE) is a potential surrogate marker for detecting tissue injuries. 99mTc-labeled duramycin is a peptide-based imaging agent that binds PE with high affinity and specificity. The goal of the current study was to investigate the clearance kinetics of 99mTc-labeled duramycin in a large animal model (normal pigs) and to assess its uptake in the heart using a pig model of myocardial ischemia-reperfusion injury. Methods The clearance and distribution of intravenously injected 99mTc-duramycin were characterized in sham-operated animals (n = 5). In a closed chest model of myocardial ischemia, coronary occlusion was induced by balloon angioplasty (n = 9). 99mTc-duramycin (10-15 mCi) was injected intravenously at 1 hour after reperfusion. SPECT/CT was acquired at 1 and 3 hours after injection. Cardiac tissues were analyzed for changes associated with acute cellular injuries. Autoradiography and gamma counting was used to determine radioactivity uptake. For the remaining animals, 99mTc-tetrafosamin scan was performed on the second day to identify the infarct site. Results Intravenously injected 99mTc-duramycin cleared from circulation predominantly via the renal/urinary tract with an α-phase half-life of 3.6 ± 0.3 minutes and β-phase half-life of 179.9 ± 64.7 minutes. In control animals, the ratios between normal heart and lung were 1.76 ± 0.21, 1.66 ± 0.22, 1.50 ± 0.20 and 1.75 ± 0.31 at 0.5, 1, 2 and 3 hours post injection, respectively. The ratios between normal heart and liver were 0.88 ± 0.13, 0.80 ± 0.13, 0.82 ± 0.19 and 0.88 ± 0.14. In vivo visualization of focal radioactivity uptake in the ischemic heart was attainable as early as 30 min post injection. The in vivo ischemic-to-normal uptake ratios were 3.57 ± 0.74 and 3.69 ± 0.91 at 1 and 3 hours post injection, respectively. Ischemic-to-lung ratios were 4.89 ± 0.85 and 4.93 ± 0.57; and ischemic-to-liver ratios were 2.05 ± 0.30 to 3.23 ± 0

  14. Thermodynamic description of Tc(iv) solubility and hydrolysis in dilute to concentrated NaCl, MgCl2 and CaCl2 solutions.

    PubMed

    Yalçıntaş, Ezgi; Gaona, Xavier; Altmaier, Marcus; Dardenne, Kathy; Polly, Robert; Geckeis, Horst

    2016-06-07

    We present the first systematic investigation of Tc(iv) solubility, hydrolysis and speciation in dilute to concentrated NaCl, MgCl2 and CaCl2 systems, and comprehensive thermodynamic and activity models for the system Tc(4+)-H(+)-Na(+)-Mg(2+)-Ca(2+)-OH(-)-Cl(-)-H2O using both SIT and Pitzer approaches. The results are advancing the fundamental scientific understanding of Tc(iv) solution chemistry and are highly relevant in the applied context of nuclear waste disposal. The solubility of Tc(iv) was investigated in carbonate-free NaCl-NaOH (0.1-5.0 M), MgCl2 (0.25-4.5 M) and CaCl2 (0.25-4.5 M) solutions within 2 ≤ pHm≤ 14.5. Undersaturation solubility experiments were performed under an Ar atmosphere at T = 22 ± 2 °C. Strongly reducing conditions (pe + pHm≤ 2) were imposed with Na2S2O4, SnCl2 and Fe powder to stabilize technetium in the +IV redox state. The predominance of Tc(iv) in the aqueous phase was confirmed by solvent extraction and XANES/EXAFS spectroscopy. Solid phase characterization was accomplished after attaining thermodynamic equilibrium using XRD, SEM-EDS, XANES/EXAFS, TG-DTA and quantitative chemical analysis, and indicated that TcO2·0.6H2O(s) exerts solubility-control in all evaluated systems. The definition of the polyatomic Tc3O5(2+) species instead of TcO(2+) is favoured under acidic conditions, consistently with slope analysis (mTcvs. pHm) of the solubility data gained in this work and spectroscopic evidence previously reported in the literature. The additional formation of Tc(iv)-OH/O-Cl aqueous species in concentrated chloride media ([Cl(-)] = 9 M) and pHm≤ 4 is suggested by solubility and EXAFS data. The pH-independent behaviour of the solubility observed under weakly acidic to weakly alkaline pHm conditions can be explained with the equilibrium reaction TcO2·0.6H2O(s) + 0.4H2O(l) ⇔ TcO(OH)2(aq). Solubility data determined in dilute NaCl systems with pHm≥ 11 follow a well-defined slope of +1, consistent with the predominance of

  15. Sialoadhesin (Sn) maps to mouse chromosome 2 and human chromosome 20 and is not linked to the other members of the Sialoadhesin family, CD22, MAG, and CD33

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mucklow, S.; Hartnell, A.; Crocker, P.R.

    1995-07-20

    Sialoadhesin is a cell-cell interaction molecule expressed by subpopulations of tissue macrophages. It contains 17 immunoglobulin (Ig)-like domains and is structurally related to CD22, MAG, and CD33. These molecules establish a distinct family of sialic acid-dependent adhesion molecules, the sialoadhesin family. We have mapped the rodent sialoadhesin gene, Sn, to chromosome 2F-H1 by in situ hybridization (ISH) and shown linkage to Il1b and four other markers by backcross linkage analysis. We have also used ISH and a human-mouse somatic cell hybrid panel to localize the human sialoadhesin gene, SN, to the conserved syntenic region on human chromosome 20p13. This demonstratesmore » that the sialoadhesin gene is not linked to the other members of the sialoadhesin family, CD22, MAG. and CD33, which have been independently mapped to the distal region of mouse chromosome 7 and to human chromosome 19q13.1-3. 19 refs., 1 fig.« less

  16. Microwave heating of a high-Tc YBa2Cu3O6.9 superconductor through a Josephson-junction system

    NASA Astrophysics Data System (ADS)

    Stankowski, J.; Czyak, B.; Martinek, J.

    1990-12-01

    An overheating of a Josephson-junction system (JJS) in ceramic YBa2Cu3O6.9 samples was induced by microwave irradiation in a microwave cavity. The amplitude of the Josephson microwave absorption (JMA) was used as a monitor of the local JJS temperature. The difference between the JJS temperature and a sample temperature depends linearly on the power of the microwave field. A thermal hysteresis of Tc for heating and cooling is proportional to the microwave power applied in the JMA experiment.

  17. Thermodynamics of superconducting Nb3Al, Nb3Ge, Nb3Sn, and V3Ga

    NASA Astrophysics Data System (ADS)

    Mitrović, B.; Schachinger, E.; Carbotte, J. P.

    1984-06-01

    We have calculated the superconducting thermodynamic properties for several high-transition-temperature A15 compounds: Nb-Al, Nb-Ge, Nb-Sn, and V-Ga. In our calculations we have used the tunneling electron-phonon-coupling spectra α2F for all four systems considered, and in the case of Nb-Al and Nb-Ge we have also used α2F=CG, where G is the measured generalized phonon density of states and C is a constant. We find that all Nb-based A15 compounds display similar thermodynamic properties, which do not depend explicitly on the band density of states: 2Δ0κBTc≅4.6, ΔCγTc≅2.5-2.6,-Tc[dHc(T)dT]TcHc(0)≅2.1, γ[TcHc(0)]2≅0.134, and positive D(t)'s with the maximum value around 0.02. For Nb3Sn we find good agreement between the calculated properties and the old specific-heat experimental results (γ≅52 mJ/mol K2). The same applies to V3Ga, where the theoretical results have been compared with the experiments of Junod et al. However, we do not find good agreement between calculated ΔCγTc, - Tc[dHc(T)dT]TcHc(0), γ[TcHc(0)]2, and experimental values for Nb3Al and Nb3Ge, presumably due to broadened transitions. It is argued that the tunneling experiments underestimate the value of the gap which should be associated with the inverted α2F.

  18. Simultaneous acquisition of (99m)Tc- and (123)I-labeled radiotracers using a preclinical SPECT scanner with CZT detectors.

    PubMed

    Kobayashi, Masato; Matsunari, Ichiro; Nishi, Kodai; Mizutani, Asuka; Miyazaki, Yoshiharu; Ogai, Kazuhiro; Sugama, Jyunko; Shiba, Kazuhiro; Kawai, Keiichi; Kinuya, Seigo

    2016-05-01

    Simultaneous acquisition of (99m)Tc and (123)I was evaluated using a preclinical SPECT scanner with cadmium zinc telluride (CZT)-based detectors. 10-ml cylindrical syringes contained about 37 MBq (99m)Tc-tetrofosmin ((99m)Tc-TF) or 37 MBq (123)I-15-(p-iodophenyl)-3R,S-methyl pentadecanoic acid ((123)I-BMIPP) were used to assess the relationship between these SPECT radioactive counts and radioactivity. Two 10-ml syringes contained 100 or 300 MBq (99m)Tc-TF and 100 MBq (123)I-BMIPP to assess the influence of (99m)Tc upscatter and (123)I downscatter, respectively. A rat-sized cylindrical phantom also contained both 100 or 300 MBq (99m)Tc-TF and 100 MBq (123)I-BMIPP. The two 10-ml syringes and phantom were scanned using a pinhole collimator for rats. Myocardial infarction model rats were examined using 300 MBq (99m)Tc-TF and 100 MBq (123)I-BMIPP. Two 1-ml syringes contained 105 MBq (99m)Tc-labeled hexamethylpropyleneamine oxime ((99m)Tc-HMPAO) and 35 MBq (123)I-labeled N-ω-fluoropropyl-2β-carbomethoxy-3β-(4-iodophenyl) nortropane ((123)I-FP-CIT). The two 1-ml syringes were scanned using a pinhole collimator for mice. Normal mice were examined using 105 MBq (99m)Tc-HMPAO and 35 MBq (123)I-FP-CIT. The relationship between SPECT radioactive counts and radioactivity was excellent. Downscatter contamination of (123)I-BMIPP exhibited fewer radioactive counts for 300 MBq (99m)Tc-TF without scatter correction (SC) in 125-150 keV. There was no upscatter contamination of (99m)Tc-TF in 150-175 keV. In the rat-sized phantom, the radioactive count ratio decreased to 4.0 % for 300 MBq (99m)Tc-TF without SC in 125-150 keV. In the rats, myocardial images and radioactive counts of (99m)Tc-TF with the dual tracer were identical to those of the (99m)Tc-TF single injection. Downscatter contamination of (123)I-FP-CIT was 4.2 % without SC in 125-150 keV. In the first injection of (99m)Tc-HMPAO and second injection of (123)I-FP-CIT, brain images and radioactive counts

  19. Clinical audit of patients hospitalized due to COPD exacerbation. MAG-1 Study.

    PubMed

    Escarrabill, Joan; Torrente, Elena; Esquinas, Cristina; Hernández, Carme; Monsó, Eduard; Freixas, Montserrat; Almagro, Pere; Tresserras, Ricard

    2015-10-01

    Hospitalizations for acute exacerbation of COPD (AECOPD) generate high consumption of health resources, frequent readmissions and high mortality. The MAG -1 study aims to identify critical points to improve the care process of severe AECOPD requiring hospitalization. Observational study, with review of clinical records of patients admitted to hospitals of the Catalan public network for AECOPD. The centers were classified into 3 groups according to the number of discharges/year. Demographic and descriptive data of the previous year, pharmacological treatment, care during hospitalization and discharge process and follow-up, mortality and readmission at 30 and 90 days were analyzed. A total of 910 patients (83% male) with a mean age of 74.3 (+10.1) years and a response rate of 70% were included. Smoking habit was determined in only 45% of cases, of which 9% were active smokers. In 31% of cases, no previous lung function data were available. Median hospital stay was 7 days (IQR 4-10), increasing according the complexity of the hospital. Mortality from admission to 90 days was 12.4% with a readmission rate of 49%. An inverse relationship between length of hospital stay and readmission within 90 days was observed. In a large number of medical records, smoking habit and lung function tests were not appropriately reported. Average hospital stay increases with the complexity of the hospital, but longer stays appear to be associated with lower mortality at follow-up. Copyright © 2014 SEPAR. Published by Elsevier Espana. All rights reserved.

  20. Role of CD8 Regulatory T Cells versus Tc1 and Tc17 Cells in the Development of Human Graft-versus-Host Disease.

    PubMed

    Gutiérrez-Hoya, Adriana; López-Santiago, Rubén; Vela-Ojeda, Jorge; Montiel-Cervantes, Laura; Rodríguez-Cortés, Octavio; Rosales-García, Víctor; Paredes-Cervantes, Vladimir; Flores-Mejía, Raúl; Sandoval-Borrego, Daniela; Moreno-Lafont, Martha

    2017-01-01

    CD8 + T cells that secrete proinflammatory cytokines play a central role in exacerbation of inflammation; however, a new subpopulation of CD8 regulatory T cells has recently been characterized. This study analyzes the prominent role of these different subpopulations in the development of graft-versus-host disease (GVHD). Samples from 8 healthy donors mobilized with Filgrastim® (G-CSF) and 18 patients who underwent allogeneic hematopoietic stem cell transplantation (HSCT) were evaluated by flow cytometry. Mobilization induced an increase in Tc1 ( p < 0.01), Th1 ( p < 0.001), Tc17 ( p < 0.05), and CD8 + IL-10 + cells ( p < 0.05), showing that G-CSF induces both pro- and anti-inflammatory profiles. Donor-patient correlation revealed a trend ( p = 0.06) toward the development of GVHD in patients who receive a high percentage of Tc1 cells. Patients with acute GVHD (aGVHD), either active or controlled, and patients without GVHD were evaluated; patients with active aGVHD had a higher percentage of Tc1 ( p < 0.01) and Tc17 ( p < 0.05) cells, as opposed to patients without GVHD in whom a higher percentage of CD8 Treg cells ( p < 0.01) was found. These findings indicate that the increase in Tc1 and Tc17 cells is associated with GVHD development, while regulatory CD8 T cells might have a protective role in this disease. These tests can be used to monitor and control GVHD.

  1. Role of CD8 Regulatory T Cells versus Tc1 and Tc17 Cells in the Development of Human Graft-versus-Host Disease

    PubMed Central

    Gutiérrez-Hoya, Adriana; López-Santiago, Rubén; Vela-Ojeda, Jorge; Montiel-Cervantes, Laura; Rodríguez-Cortés, Octavio; Rosales-García, Víctor; Flores-Mejía, Raúl; Sandoval-Borrego, Daniela

    2017-01-01

    CD8+ T cells that secrete proinflammatory cytokines play a central role in exacerbation of inflammation; however, a new subpopulation of CD8 regulatory T cells has recently been characterized. This study analyzes the prominent role of these different subpopulations in the development of graft-versus-host disease (GVHD). Samples from 8 healthy donors mobilized with Filgrastim® (G-CSF) and 18 patients who underwent allogeneic hematopoietic stem cell transplantation (HSCT) were evaluated by flow cytometry. Mobilization induced an increase in Tc1 (p < 0.01), Th1 (p < 0.001), Tc17 (p < 0.05), and CD8+IL-10+ cells (p < 0.05), showing that G-CSF induces both pro- and anti-inflammatory profiles. Donor-patient correlation revealed a trend (p = 0.06) toward the development of GVHD in patients who receive a high percentage of Tc1 cells. Patients with acute GVHD (aGVHD), either active or controlled, and patients without GVHD were evaluated; patients with active aGVHD had a higher percentage of Tc1 (p < 0.01) and Tc17 (p < 0.05) cells, as opposed to patients without GVHD in whom a higher percentage of CD8 Treg cells (p < 0.01) was found. These findings indicate that the increase in Tc1 and Tc17 cells is associated with GVHD development, while regulatory CD8 T cells might have a protective role in this disease. These tests can be used to monitor and control GVHD. PMID:28164135

  2. Evolution of Magnetized Liner Inertial Fusion (MagLIF) Targets

    DOE PAGES

    Fooks, J. A.; Carlson, L. C.; Fitzsimmons, P.; ...

    2017-12-19

    Here, the magnetized liner inertial fusion (MagLIF) experimental campaign conducted at the University of Rochester’s Laboratory for Laser Energetics (LLE) has evolved significantly since its start in 2014. Scientific requirements and OMEGA EP system technology both have progressed, resulting in necessary and available updates to the target design. These include, but are not limited to: optimizing target dimensions and aspect ratios to maximize survival at desired pressures; coating target components to enhance physics diagnosis; precision-machining diagnostic windows along the axis of the target; improving fiducial placement reproducibility and reducing subsequent assembly time by 50%; and implementing gas-pressure transducers on themore » targets. In addition, target fabrication techniques have changed and improved, allowing for simpler target reproducibility and decreased assembly time. To date, eleven variations of targets have been fabricated, with successful target fielding ranging from 1 to 20atm internal pressure and a maximum survivability of 33atm.« less

  3. MagLIF Pre-Heat Optimization on the PECOS Surrogacy Platform

    NASA Astrophysics Data System (ADS)

    Geissel, Matthias; Harvey-Thompson, A. J.; Ampleford, D.; Awe, T. J.; Bliss, D. E.; Glinsky, M. E.; Gomez, M. R.; Harding, E.; Hansen, S. B.; Jennings, C.; Kimmel, M. W.; Knapp, P. F.; Lewis, S. M.; Peterson, K.; Rochau, G. A.; Schollmeier, M.; Schwarz, J.; Shores, J. E.; Slutz, S. A.; Sinars, D. B.; Smith, I. C.; Speas, C. S.; Vesey, R. A.; Weis, M. R.; Porter, J. L.

    2017-10-01

    Sandia's MagLIF Program is using the PECOS target area as a platform to optimize the coupling of laser energy into the fuel. After developing laser pulse shapes that reduced SBS and improved energy deposition (presented last year), we will report on the effect on integrated experiments with Z. Despite encouraging results, questions remained about the equivalency of He, (PECOS studies), versus D2 (Z). Furthermore, simulations imply that the goal of at least 1 kJ in the fuel will require higher pressures, requiring a re-design of the gas delivery system. We will present recent results for backscatter measurements and energy deposition profiles in 60 psi and 90 psi deuterium fills and compare them to previously studied helium fills. Sandia National Labs is managed and operated by National Technology and Engineering Solutions of Sandia, LLC., a subsidiary of Honeywell International, Inc., for U.S. DoE/NNSA under contract DE-NA0003525.

  4. Evolution of Magnetized Liner Inertial Fusion (MagLIF) Targets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fooks, J. A.; Carlson, L. C.; Fitzsimmons, P.

    Here, the magnetized liner inertial fusion (MagLIF) experimental campaign conducted at the University of Rochester’s Laboratory for Laser Energetics (LLE) has evolved significantly since its start in 2014. Scientific requirements and OMEGA EP system technology both have progressed, resulting in necessary and available updates to the target design. These include, but are not limited to: optimizing target dimensions and aspect ratios to maximize survival at desired pressures; coating target components to enhance physics diagnosis; precision-machining diagnostic windows along the axis of the target; improving fiducial placement reproducibility and reducing subsequent assembly time by 50%; and implementing gas-pressure transducers on themore » targets. In addition, target fabrication techniques have changed and improved, allowing for simpler target reproducibility and decreased assembly time. To date, eleven variations of targets have been fabricated, with successful target fielding ranging from 1 to 20atm internal pressure and a maximum survivability of 33atm.« less

  5. Trypanosoma cruzi H+-ATPase 1 (TcHA1) and 2 (TcHA2) genes complement yeast mutants defective in H+ pumps and encode plasma membrane P-type H+-ATPases with different enzymatic properties.

    PubMed

    Luo, Shuhong; Scott, David A; Docampo, Roberto

    2002-11-15

    Previous studies in Trypanosoma cruzi have shown that intracellular pH homeostasis requires ATP and is affected by H(+)-ATPase inhibitors, indicating a major role for ATP-driven proton pumps in intracellular pH control. In the present study, we report the cloning and sequencing of a pair of genes linked in tandem (TcHA1 and TcHA2) in T. cruzi which encode proteins with homology to fungal and plant P-type proton-pumping ATPases. The genes are expressed at the mRNA level in different developmental stages of T. cruzi: TcHA1 is expressed maximally in epimastigotes, whereas TcHA2 is expressed predominantly in trypomastigotes. The proteins predicted from the nucleotide sequence of the genes have 875 and 917 amino acids and molecular masses of 96.3 and 101.2 kDa, respectively. Full-length TcHA1 and an N-terminal truncated version of TcHA2 complemented a Saccharomyces cerevisiae strain deficient in P-type H(+)-ATPase activity, the proteins localized to the yeast plasma membrane, and ATP-driven proton pumping could be detected in proteoliposomes reconstituted from plasma membrane purified from transfected yeast. The reconstituted proton transport activity was reduced by inhibitors of P-type H(+)-ATPases. C-terminal truncation did not affect complementation of mutant yeast, suggesting the lack of C-terminal autoinhibitory domains in these proteins. ATPase activity in plasma membrane from TcHA1- and (N-terminal truncated) TcHA2-transfected yeast was inhibited to different extents by vanadate, whereas the latter yeast strain was more resistant to extremes of pH, suggesting that the native proteins may serve different functions at different stages in the T. cruzi life cycle.

  6. TC > 0.05 as a Pharmacokinetic Parameter of Paclitaxel for Therapeutic Efficacy and Toxicity in Cancer Patients.

    PubMed

    Xin, D S; Zhou, L; Li, C Z; Zhang, S Q; Huang, H Q; Qiu, G D; Lin, L F; She, Y Q; Zheng, J T; Chen, C; Fang, L; Chen, Zhe-Sheng; Zhang, S Y

    2018-03-05

    Paclitaxel (PTX) has remarkable anti-tumor activity, but it causes severe toxicities. There is an urgent need to seek an appropriate pharmacokinetic parameter of PTX to improve treatment efficacy and reduce adverse effects. To evaluate the association of pharmacokinetic parameter TC>0.05 of paclitaxel (PTX) and its therapeutic efficacy and toxicity in patients with solid tumors. A total of 295 patients with ovarian cancer, esophageal cancer, breast cancer, and non-small cell lung cancer (NSCLC), who were admitted to the Tumor Hospital of Shantou University Medical College, China, were recruited for this study. Patients received 3 weeks of PTX chemotherapy. The plasma concentrations of PTX were examined using the MyPaclitaxelTM kit. The patients' PTX TC>0.05 (the time during which PTX plasma concentration exceed 0.05 μmol/L) were calculated based on pharmacokinetic analysis. The results showed that: (1) the concentrations of PTX in these 295 patients ranged from 0.0358-0.127 μmol/L; (2) the PTX TC> 0.05 ranged from 14 to 38 h with a median time of 27 h; (3) among all treatment cycles, there was a statistically significant difference in the PTX TC>0.05 between CR+PR and SD+PD; (4) with the increasing value of TC>0.05, level of leukopenia and leukopenic fever increased; (5) high PTX TC>0.05 led to the occurrence of neutropenia, neutropenic fever, severe anemia, and severe peripheral neurotoxicity. Taken together, our results indicated that the pharmacokinetic parameter PTX TC>0.05 was an effective measure of treatment efficacy and toxicity in patients with solid tumors. Maintaining PTX TC>0.05 at 26 to 30 h could improve its efficacy and reduce the incidence of leukopenia, neutropenia, anemia, and peripheral neurotoxicity in these patients. PTX TC>0.05 is a key pharmacokinetic parameter of PTX which should be monitored to optimize individual treatment in patients with solid tumors. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  7. Correlation of Tc17 cells at early stages after allogeneic hematopoietic stem cell transplantation with acute graft-versus-host disease.

    PubMed

    Wang, Ling; Zhao, Peng; Song, Lingling; Yan, Fahong; Shi, Chunlei; Li, Ying; Han, Mingzhe; Lan, Ketao

    2016-12-01

    Acute graft-versus-host disease (aGVHD) is associated with an immune dysregulation usually mediated by T lymphocytes. Recently, IL-17-producing T cells including Th17 and Tc17 cells have been implicated in immune-related diseases. However, their roles in aGVHD remain uncertain. In the study, we analyzed IL-17-producing cell recovery and association with the occurrence of aGVHD. While Th17 cells steadily recovered, Tc17 cell numbers remained unaltered during the first 3months after transplantation. Occurrence of aGVHD was correlated with increased level of Tc17 cells at the second months after allo-SCT. Interestingly, Tc17 cells were negatively associated with CD4 + CD25 + FOXP3 + regulatory T (Treg) cells, which was an important prognostic predictor in patients with aGVHD. In addition, we found that Tc17 numbers increased as the increased concentrations of TGF-β and IL-6, which are known to drive Th17 polarization. These finding supported that Tc17 subset is involved in the immunopathology of aGVHD. Blocking the abnormally increased number of Tc17 may be a reasonable therapeutic strategy for aGVHD. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Preparation of Magnetic Carbon Nanotubes (Mag-CNTs) for Biomedical and Biotechnological Applications

    PubMed Central

    Masotti, Andrea; Caporali, Andrea

    2013-01-01

    Carbon nanotubes (CNTs) have been widely studied for their potential applications in many fields from nanotechnology to biomedicine. The preparation of magnetic CNTs (Mag-CNTs) opens new avenues in nanobiotechnology and biomedical applications as a consequence of their multiple properties embedded within the same moiety. Several preparation techniques have been developed during the last few years to obtain magnetic CNTs: grafting or filling nanotubes with magnetic ferrofluids or attachment of magnetic nanoparticles to CNTs or their polymeric coating. These strategies allow the generation of novel versatile systems that can be employed in many biotechnological or biomedical fields. Here, we review and discuss the most recent papers dealing with the preparation of magnetic CNTs and their application in biomedical and biotechnological fields. PMID:24351838

  9. Preparation of magnetic carbon nanotubes (Mag-CNTs) for biomedical and biotechnological applications.

    PubMed

    Masotti, Andrea; Caporali, Andrea

    2013-12-18

    Carbon nanotubes (CNTs) have been widely studied for their potential applications in many fields from nanotechnology to biomedicine. The preparation of magnetic CNTs (Mag-CNTs) opens new avenues in nanobiotechnology and biomedical applications as a consequence of their multiple properties embedded within the same moiety. Several preparation techniques have been developed during the last few years to obtain magnetic CNTs: grafting or filling nanotubes with magnetic ferrofluids or attachment of magnetic nanoparticles to CNTs or their polymeric coating. These strategies allow the generation of novel versatile systems that can be employed in many biotechnological or biomedical fields. Here, we review and discuss the most recent papers dealing with the preparation of magnetic CNTs and their application in biomedical and biotechnological fields.

  10. Molecular beam epitaxy growth of SmFeAs(O,F) films with Tc = 55 K using the new fluorine source FeF3

    NASA Astrophysics Data System (ADS)

    Sakoda, Masahito; Ishii, Akihiro; Takinaka, Kenji; Naito, Michio

    2017-07-01

    REFeAs(O,F) (RE: rare-earth element) has the highest-Tc (˜58 K) among the iron-based superconductors, but a thin-film growth of REFeAs(O,F) is difficult. This is because it is not only a complex compound consisting of five elements but also requires doping of highly reactive fluorine to achieve superconductivity. We have reported in our previous article that fluorine can be supplied to a film by subliming solid-state fluorides such as FeF2 or SmF3. In this article, we report on the growth of SmFeAs(O,F) using FeF3 as an alternative fluorine source. FeF3 is solid at ambient temperatures and decomposes at temperatures as low as 100-200 °C, and releases fluorine-containing gas during the thermal decomposition. With this alternative fluorine source, we have grown SmFeAs(O,F) films with Tc as high as 55 K. This achievement demonstrates that FeF3 has potential as a fluorine source that can be employed ubiquitously for a thin-film growth of any fluorine containing compounds. One problem specific to FeF3 is that the compound is highly hydroscopic and contains a substantial amount of water even in its anhydrous form. In this article, we describe how to overcome this specific problem.

  11. A novel Tc-99 m and fluorescence labeled peptide as a multimodal imaging agent for targeting angiogenesis in a murine tumor model.

    PubMed

    Kim, Myoung Hyoun; Kim, Chang Guhn; Kim, Seul-Gi; Kim, Dae-Weung

    2016-11-01

    The serine-aspartic acid-valine (SDV) peptide binds specifically to integrin α V β 3 . In the present study, we successfully developed a TAMRA-GHEG-ECG-SDV peptide labeled with both Tc-99 m and TAMRA to target the integrin α V β 3 of tumor cells; furthermore, we evaluated the diagnostic performance of Tc-99 m TAMRA-GHEG-ECG-SDV as a dual-modality imaging agent for tumor of the murine model. TAMRA-GHEG-ECG-SDV was synthesized using Fmoc solid-phase peptide synthesis. Radiolabeling of TAMRA-GHEG-ECG-SDV with Tc-99 m was done using ligand exchange methods. Labeling stability and cytotoxicity studies were performed. Gamma camera imaging, biodistribution and ex vivo imaging studies were performed in murine models with HT-1080 and HT-29 tumors. A tumor tissue slide was prepared and analyzed using confocal microscopy. After radiolabeling procedures with Tc-99 m, the Tc-99 m TAMRA-GHEG-ECG-SDV complexes were prepared in high yield (>99%). In the gamma camera imaging study, a substantial uptake of Tc-99 m TAMRA-GHEG-ECG-SDV into HT-1080 tumor (integrin α V β 3 positive) and low uptake of Tc-99 m TAMRA-GHEG-ECG-SDV into HT-29 tumor (integrin α V β 3 negative) were demonstrated. A competition study revealed that HT-1080 tumor uptake was effectively blocked by the co-injection of an excess concentration of SDV. Specific uptake of Tc-99 m TAMRA-GHEG-ECG-SDV was confirmed by biodistribution, ex vivo imaging and confocal microscopy studies. Our in vivo and in vitro studies revealed substantial uptake of Tc-99 m TAMRA-GHEG-ECG-SDV in the integrin α V β 3 -positive tumor. Tc-99 m TAMRA-GHEG-ECG-SDV could be a good candidate for a dual-modality imaging agent targeting tumor angiogenesis. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  12. Diagnostic value of 99mTc-ethambutol scintigraphy in tuberculosis: compared to microbiological and histopathological tests.

    PubMed

    Kartamihardja, A H S; Kurniawati, Y; Gunawan, R

    2018-01-01

    Tuberculosis (TB) still remains the world's endemic infection. TB affects the lungs and any part of the body other than the lung. The diagnosis of TB has not changed much over the decades. Ethambutol is one of the first line treatments for TB. It can be labeled using 99m Tc. 99m Tc-ethambutol will be accumulated in the site of TB lesion and can be imaged using gamma camera. The aim of this study was to evaluate the diagnostic value of 99m Tc-ethambutol scintigraphy in detecting and localizing of TB. Retrospective cross-sectional study was done. Subjects were patients suspected of having TB infection. Whole body and SPECT-CT imaging at the suspected area was done 1 and 4 h after injection of 370-555 MBq 99m Tc-ethambutol. 99m Tc-ethambutol scintigraphy was analyzed visually. The results were compared with that of histopathological or microbiological tests. Statistical analysis was done to determine the sensitivity, specificity, PPV, NPV and accuracy. One hundred and sixty-eight subjects were involved in this study. There were 110 men and 58 women with mean age of 34.52 ± 11.94 years. There were concordance results in 156 (92.86%) and discordant in 12 (7.14%) subjects between 99m Tc-ethambutol scintigraphy and histopathological or microbiological result. The sensitivity, specificity, PPV, NPV and accuracy of 99m Tc-ethambutol scintigraphy in the diagnosis of pulmonary TB were 93.9, 85.7, 93.9, 85.7 and 91.4%, respectively, for extra-pulmonary TB 95.5, 77.8, 97.9, 63.6, and 85.1%, respectively, and for total tuberculosis 94.9, 83.3, 96.3, 78.1 and 92.8%, respectively. There was no side effect observed in this study. 99m Tc-ethambutol scintigraphy is a useful diagnostic imaging technique to detect and localize intra- and extra-pulmonary TB. It is safe to be performed even in pediatric patient. Consuming ethambutol less than 2 weeks did not influence the result.

  13. Achievement of trifecta in minimally invasive partial nephrectomy correlates with functional preservation of operated kidney: a multi-institutional assessment using MAG3 renal scan.

    PubMed

    Zargar, Homayoun; Porpiglia, Francesco; Porter, James; Quarto, Giuseppe; Perdona, Sisto; Bertolo, Riccardo; Autorino, Riccardo; Kaouk, Jihad H

    2016-07-01

    To validate and compare the values of "MIC" and "trifecta" as predictors of operated kidney functional preservation in a multi-institutional cohort of patients undergoing minimally invasive PN. We retrospectively reviewed records of consecutive cases of minimally invasive PN performed for cT1 renal masses in 4 centers from 2009 to 2013. Inclusion criteria consisted of availability of a renal scan obtained within 2 weeks prior to surgery and follow-up renal scan 3-6 months after the surgery. The primary endpoint of the study was to compare the degree of ipsilateral renal function preservation assessed by MAG3 renal scan in relation to achievement of MIC and trifecta. Total of 351 patients met our inclusion criteria. The rates of trifecta achievement for cT1a and cT1b tumors were 78.9 and 60.6 %, respectively. The rate of MIC achievement for cT1a tumors and cT1b tumors was 60.3 and 31.7 %, respectively. On multivariable linear regression model, only the degree of tumor complexity assessed by R.E.N.A.L nephrometry score [coefficient B -1.8 (-2.7, -0.9); p < 0.0001] and the achievement of trifecta [coefficient B 6.1 (2.4,9.8); p = 0.014] or MIC (coefficient B 7.2 (3.8,0.6); p < 0.0001) were significant clinical factors predicting ipsilateral split function preservation. Achievement of both MIC and "trifecta" is associated with higher proportion of split renal function preservation for cT1 tumors after minimally invasive PN. Thus, these outcome measures can be regarded not only as markers of surgical quality, but also as reliable surrogates for predicting functional outcome in the operated kidney.

  14. The first experience of using 99mTc-Al2O3-based radiopharmaceutical for the detection of sentinel lymph nodes in cervical cancer patients

    NASA Astrophysics Data System (ADS)

    Sinilkin, I. G.; Chernov, V. I.; Lyapunov, A. Yu.; Medvedeva, A. A.; Zelchan, R. V.; Chernyshova, A. L.; Kolomiets, L. A.

    2016-08-01

    The purpose of the study was to evaluate the feasibility of using 99mTc-Al2O3-based radiopharmaceutical, a novel molecular imaging agent for sentinel lymph node detection in patients with invasive cervical cancer. The study included 23 cervical cancer patients (T1aNxMx-T2bNxMx) treated at the Tomsk Cancer Research Institute. In the 18 hours before surgery, 80 MBq of the 99mTc-Al2O3 in peritumoral injected, followed by single-photon emission computed tomography (SPECT) of the pelvis and intraoperative SLN identification. Twenty-seven SLNs were detected by SPECT, and 34 SLNs were identified by intraoperative gamma probe. The total number of identified SLNs per patient ranged from 1 to 3 (the mean number of SLNs was 1.4 per patient). The most common site for SLN detection was the external iliac region (57.2%), followed by the internal iliac (14%), obturator (14%), presacral and retrosacral regions (14%), and the parametrial region (1%). Sensitivity in detecting SLNs was 100% for intraoperative SLN identification and 79% for SPECT image.

  15. Synthesis and Characterization of Tc(I) Carbonyl Nitrosyl Species Relevant to the Hanford Tank Waste: FY 2016 Status Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hall, Gabriel B.; Chatterjee, Sayandev; Levitskaia, Tatiana G.

    Among long-lived radioactive constituents in the Hanford tank waste, Tc presents a unique challenge in that it exists predominantly in the liquid phase, generally in the anionic form of pertechnetate, TcO 4 -, which is highly volatile at low-activity waste (LAW) vitrification melter temperatures and mobile in the Hanford site’s subsurface environment. The complex behavior of Tc under storage, treatment, and immobilization conditions significantly affects its management options, which to-date remain uncertain. In strongly alkaline environments, Tc exists as pertechnetate, TcO 4 - (oxidation state +7), and in the reduced forms (oxidation state < +7) collectively known as non-pertechnetate species.more » Pertechnetate is a well-characterized, anionic Tc species that can be removed from LAW by anion exchange or solvent extraction methods. There is no definitive information on the origin of the non-pertechnetate Tc species, nor is there a comprehensive description of their composition and behavior. It has been recently proposed that the non-pertechnetate species can comprise Tc(I) metal center and carbonyl or mixed carbonyl nitrosyl ligands stabilizing low-valent Tc. Recent work by our group has significantly expanded this previous work, generating a series of Tc(I) carbonyl compounds and demonstrating that they can be generated from reduction of TcO 4 - in the simulated Hanford tank waste in presence of CO at elevated temperature (Levitskaia et al. 2014). These results are consistent with the previous proposal that [Tc(CO) 3] + species can be present in the Hanford tank waste and suggest that the low Tc(I) oxidation state is stabilized by the π-accepting ability of the CO ligands. The continuation work has been initiated to develop model Tc carbonyl nitrosyl compounds and investigate their potential presence in the Hanford tank wastes. This report summarizes our to-date results.« less

  16. Somatostatin receptor scintigraphy using 99mTc-EDDA/HYNIC-TOC in patients with medullary thyroid carcinoma.

    PubMed

    Czepczyński, Rafał; Parisella, Maria Gemma; Kosowicz, Jerzy; Mikołajczak, Renata; Ziemnicka, Katarzyna; Gryczyńska, Maria; Sowiński, Jerzy; Signore, Alberto

    2007-10-01

    Several new somatostatin analogues have been developed for the diagnosis and therapy of different tumours. Since somatostatin receptors are often over-expressed in medullary thyroid carcinoma (MTC), the aim of our study was to evaluate the utility of scintigraphy with the somatostatin analogue (99m)Tc-EDDA/HYNIC-TOC in MTC in comparison with other diagnostic techniques. Forty-five patients with MTC, aged 14-83 years, were investigated. Scintigraphy using (99m)Tc-EDDA/HYNIC-TOC (Tektrotyd) was performed 2 and 4 h post injection of 740 MBq (20 mCi) of the tracer. Other imaging techniques were also applied and analysed in individual cases (ultrasonography, computed tomography, (99m)Tc(V)-DMSA, (131)I-MIBG, (99m)Tc-MDP, (111)In-DTPA-octreotide and (18)F-FDG-PET) and compared with (99m)Tc-EDDA/HYNIC-TOC. In group 1 (eight patients before thyroidectomy), uptake of the tracer was found in the primary tumours. In group 2 (six patients with remission), a false positive result was found in one patient; in the remaining five patients, no pathological foci were visualised. In group 3 (31 patients with post-surgical hypercalcitoninaemia), scintigraphy was true positive in 23 patients (74.2%): uptake in the thyroid bed was found in five patients, in the lymph nodes in 18 and in bone metastases in four. Using (99m)Tc-EDDA/HYNIC-TOC scintigraphy, the overall sensitivity was 79.5%, specificity 83.3%, accuracy 80.0%, positive predictive value 96.9% and negative predictive value 38.5%. (99m)Tc-EDDA/HYNIC-TOC is clinically useful for scintigraphy in the follow-up of patients with MTC. It can be used in clinical practice for preoperative evaluation, for localisation of local recurrence or distant metastases and particularly for therapy decision making.

  17. The different expression of TRPM7 and MagT1 impacts on the proliferation of colon carcinoma cells sensitive or resistant to doxorubicin

    PubMed Central

    Cazzaniga, Alessandra; Moscheni, Claudia; Trapani, Valentina; Wolf, Federica I.; Farruggia, Giovanna; Sargenti, Azzurra; Iotti, Stefano; Maier, Jeanette A. M.; Castiglioni, Sara

    2017-01-01

    The processes leading to anticancer drug resistance are not completely unraveled. To get insights into the underlying mechanisms, we compared colon carcinoma cells sensitive to doxorubicin with their resistant counterpart. We found that resistant cells are growth retarded, and show staminal and ultrastructural features profoundly different from sensitive cells. The resistant phenotype is accompanied by the upregulation of the magnesium transporter MagT1 and the downregulation of the ion channel kinase TRPM7. We demonstrate that the different amounts of TRPM7 and MagT1 account for the different proliferation rate of sensitive and resistant colon carcinoma cells. It remains to be verified whether they are also involved in the control of other “staminal” traits. PMID:28094304

  18. NMR/MRI with hyperpolarized gas and high Tc SQUID

    DOEpatents

    Schlenga, Klaus; de Souza, Ricardo E.; Wong-Foy, Annjoe; Clarke, John; Pines, Alexander

    2000-01-01

    A method and apparatus for the detection of nuclear magnetic resonance (NMR) signals and production of magnetic resonance imaging (MRI) from samples combines the use of hyperpolarized inert gases to enhance the NMR signals from target nuclei in a sample and a high critical temperature (Tc) superconducting quantum interference device (SQUID) to detect the NMR signals. The system operates in static magnetic fields of 3 mT or less (down to 0.1 mT), and at temperatures from liquid nitrogen (77K) to room temperature. Sample size is limited only by the size of the magnetic field coils and not by the detector. The detector is a high Tc SQUID magnetometer designed so that the SQUID detector can be very close to the sample, which can be at room temperature.

  19. Chondro-Protective and Antiarthritic Effects of Sulfonamido-Based Gallate-ZXHA-TC in Vitro and in Vivo.

    PubMed

    Lu, Zhenhui; Wu, Huayu; Lin, Xiao; Liu, Buming; Lin, Cuiwu; Zheng, Li; Zhao, Jinmin

    2016-06-17

    The effects of gallic acid (GA) on arthritis are limited by weak antioxidant effects and inferior biological properties of GA. We recently described a new series of synthesized GA derivatives by coupling with sulfonamides. Among these analogs, a novel compound synthesized from GA and sulfadimoxine (SDM) named ZXHA-TC exhibited the most robust anti-inflammatory potential. In this current study, the chondro-protective and antiarthritic effects of ZXHA-TC were investigated both in vitro and in vivo. In the in vitro study, ZXHA-TC exerted chondro-protective effects as evidenced by promoting cell proliferation and the maintaining of the phenotype of articular chondrocytes treated with interleukin-1-beta (IL-1β). The potential of ZXHA-TC to slow the progress of osteoarthritis (OA) was suggested by a reduction in matrix metalloproteinases (MMPs) and the up-regulation of the tissue inhibitor of metalloproteinase-1 (TIMP-1). In a rabbit anterior cruciate ligament transaction (ACLT) model of OA, ZXHA-TC exerted a protective effect on arthritis as assessed by macroscopic scores, histological, qRT-PCR, and immunohistochemical analyses. The effects of ZXHA-TC on inhibiting the production of inflammatory mediators in OA may be mediated partly by the suppression of the PI3K/AKT pathway or MAPK cascades, leading to NF-κB inactivation. Thus, this study indicates that ZXHA-TC may be developed as a potential therapeutic agent for OA.

  20. A Novel Point Mutation at Position 156 of Reverse Transcriptase from Feline Immunodeficiency Virus Confers Resistance to the Combination of (−)-β-2′,3′-Dideoxy-3′-Thiacytidine and 3′-Azido-3′-Deoxythymidine

    PubMed Central

    Smith, Robert A.; Remington, Kathryn M.; Preston, Bradley D.; Schinazi, Raymond F.; North, Thomas W.

    1998-01-01

    Mutants of feline immunodeficiency virus (FIV) resistant to (−)-β-2′,3′-dideoxy-3′-thiacytidine (3TC) were selected by culturing virus in the presence of increasing stepwise concentrations of 3TC. Two plaque-purified variants were isolated from the original mutant population, and both of these mutants were resistant to 3TC. Surprisingly, these mutants were also phenotypically resistant to 3′-azido-3′-deoxythymidine (AZT) and to the combination of 3TC and AZT. Purified reverse transcriptase (RT) from one of these plaque-purified mutants was resistant to the 5′-triphosphates of 3TC and AZT. DNA sequence analysis of the RT-encoding region of the pol gene amplified from the plaque-purified mutants revealed a Pro-to-Ser mutation at position 156 of RT. A site-directed mutant of FIV engineered to contain this Pro-156-Ser mutation was resistant to 3TC, AZT, and the combination of 3TC and AZT, confirming the role of the Pro-156-Ser mutation in the resistance of FIV to these two nucleoside analogs. This represents the first report of a lentiviral mutant resistant to the combination of AZT and 3TC due to a single, unique point mutation. PMID:9499094

  1. Influence of bidentate ligand donor types on the formation and stability in 2 + 1 fac-[MI(CO)3]+ (M = Re, 99mTc) complexes.

    PubMed

    Hayes, Thomas R; Bottorff, Shalina C; Slocumb, Winston S; Barnes, Charles L; Clark, Aurora E; Benny, Paul D

    2017-01-24

    In the last two decades, a number of chelate strategies have been proposed for the fac-[M I (CO) 3 ] + (M = Re, 99m Tc) core in radiopharmaceutical applications. However, the development of new ligands/complexes with improved function and in vivo performance has been limited in recent years. Expanding on our previous studies using the 2 + 1 labeling strategy, a series of bidentate ligands (neutral vs. anionic) containing an aromatic amine in combination with monodentate pyridine analogs or imidazole were explored to determine the influence of the bidentate and monodentate ligands on the formation and stability of the respective complexes. The 2 + 1 complexes with Re and 99m Tc were synthesized in two steps and characterized by standard radio/chemical methods. X-ray characterization and density functional theory analysis of the Re 2 + 1 complexes with the complete bidentate series with 4-dimethylaminopyridine were conducted, indicating enhanced ligand binding energies of the neutral over anionic ligands. In the 99m Tc studies, anionic bidentate ligands had significantly higher formation yields of the 2 + 1 product, but neutral ligands appear to have increased stability in an amino acid challenge assay. Both bidentate series exhibited improved stability by increasing the basicity of the pyridine ligands.

  2. Influence of Bidentate Ligand Donor Types on the Formation and Stability in 2+1 fac-[MI(CO)3]+ (M = Re, 99mTc) Complexes

    PubMed Central

    Hayes, Thomas R.; Bottorff, Shalina C.; Slocumb, Winston S.; Barnes, Charles L.; Clark, Aurora E.; Benny, Paul D.

    2017-01-01

    In the last two decades, a number of chelate strategies have been proposed for the fac-[MI(CO)3]+ (M = Re, 99mTc) core in radiopharmaceutical applications. However, the development of new ligands/complexes with improved function and in vivo performance has been limited in recent years. Expanding on our previous studies using the 2+1 labeling strategy, a series of bidentate ligands (neutral vs. anionic) containing an aromatic amine in combination with monodentate pyridine analogs or imidazole were explored to determine the influence of the bidentate and monodentate ligands on the formation and stability of the respective complexes. The 2+1 complexes with Re and 99mTc were synthesized in two steps and characterized by standard radio/chemical methods. X-ray characterization and density functional theory analysis of the Re 2+1 complexes with the complete bidentate series with 4-dimethylaminopyridine were conducted, indicating enhanced ligand binding energies of the neutral over anionic ligands. In the 99mTc studies, anionic bidentate ligands had significantly higher formation yields of the 2+1 product, but neutral ligands appear to have increased stability in an amino acid challenge assay. Both bidentate series exhibited improved stability by increasing the basicity of the pyridine ligands. PMID:28045466

  3. Trypanosoma cruzi DTU TcII presents higher blood parasitism than DTU TcI in an experimental model of mixed infection.

    PubMed

    Sales-Campos, Helioswilton; Kappel, Henrique Borges; Andrade, Cristiane Pontes; Lima, Tiago Pereira; de Castilho, Alessandra; Giraldo, Luis Eduardo Ramirez; Lages-Silva, Eliane

    2015-09-01

    Trypanosoma cruzi (Tc), the causative agent of Chagas disease, affects millions of people worldwide. One of the major characteristics of T. cruzi is related to its heterogeneity due to the variability of its biological properties, parasite growth rates, infectivity, tissue tropism, morbidity and virulence among different isolates observed during experimental or human infection. Moreover, presence of mixed infections in the same host in endemic areas is a matter of study due to its impact on clinical manifestations and disease progression. In this study, we evaluated the biological behavior of two Tc I strains AQ1-7 (AQ) and MUTUM (MT) and one Tc II strain (JG) during the acute phase of infection, in unique and mixed infections. A patent blood parasitism was detected only in mice inoculated with JG strain . In addition blood parasitism parameters (peak and average blood parasitism) were positively associated when JG and AQ strains were combined. In contrast, a negative association was observed in the JG+MUTUM group. The predominance of TcII strain over TcI strains was highlighted using the LSSP-PCR technique, which was performed in samples from hemoculture. Thus, this study showed important biological differences between different T. cruzi strains and discrete typing units (DTUs) in acute phase. Finally, we observed that blood parasitism during early period of infection seems to be more related to DTU than to a specific strain.

  4. Research on tool wearing on milling of TC21 titanium alloy

    NASA Astrophysics Data System (ADS)

    Guilin, Liu

    2017-06-01

    Titanium alloys are used in aircraft widely, but the efficiency is a problem for machining titanium alloy. In this paper, the cutting experiment of TC21 titanium alloy was studied. Cutting parameters and test methods for TC21 titanium alloy were designed. The wear behavior of TC21 titanium alloy was studied based on analysis of orthogonal test results. It provides a group of cutting parameters for TC21 titanium alloy processing.

  5. Technetium-99m galactosyl-neoglycoalbumin (Tc-NGA) liver imaging: Application in liver transplantation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woodle, E.S.; Ward, R.E.; Vera, D.R.

    1985-05-01

    Tc-NGA is a new liver imaging agent which binds to hepatic binding protein (HBP), a hepatocyte-specific membrane receptor. The purpose of the present study was to evaluate the potential role of Tc-NGA imaging in liver transplantation. The molar Tc-NGA dose was standardized according to patient weight (0.7 nmole/kg). After a 30 minute dynamic imaging study (5 mCi, IV), kinetic analysis of time activity data (heart, liver), provided values for receptor concentration, (HBP), and hepatic blood flow, Q. Eleven Tc-NGA imaging studies were performed in transplant candidates and 22 studies were performed in seven transplant recipients. Preservation damage was manifested bymore » diffuse patchiness in tracer distribution which resolved during the following two weeks. Histologically proven, localized hepatic infarcts were demonstrated in three recipients. Lobar infarction was demonstrated in one recipient. Hepatic regeneration was later demonstrated in this patient after hepatic lobectomy. Hepatic blood flow was markedly decreased in the early postoperative period, but improved with time. Increased (HBP) was demonstrated with regeneration. Markedly decreased (HBP) and Q were obtained in several candidates who died awaiting transplantation. These studies indicate that TC-NGA liver imaging provides a valuable new means for: (1) evaluation of preservation damage, (2) early demonstration of hepatic infarction, (3) evaluation of hepatic rejection, and (4) selection of patients for hepatic transplantation.« less

  6. Phenolic aminocarboxylate chelates of 99mTc as hepatobiliary agents.

    PubMed

    Hunt, F C; Maddalena, D J; Wilson, J G; Bautovich, G J

    1986-01-01

    A series of alkyl- and halogen-substituted derivatives of ethylenediamine di[o-hydroxyphenylacetic acid] (EDDHA) and N,N'-bis[2-hydroxybenzyl] ethylenediamine N,N'-diacetic acid (HBED) were complexed with 99mTc and their biodistribution was determined in rats. All complexes displayed substantial hepatobiliary excretion; of each series, 99mTc-Br-EDDHA and 99mTc-di-Cl-HBED had the maximum amount in the gastrointestinal tract. Scintigraphic studies of 99mTc-Cl-EDDHA in dogs revealed prompt imaging of the liver followed by imaging of the gall bladder as the complex was excreted into the bile.

  7. Can Positron 2D-ACAR Resolve the Electronic Structure of HIGH-Tc Superconductors?

    NASA Astrophysics Data System (ADS)

    Chan, L. P.; Lynn, K. G.; Harshman, D. R.

    We examine the ability of the positron Two-Dimensional Angular Correlation Annihilation Radiation (2D-ACAR) technique to resolve the electronic structures of high-Tc cuprate superconductors. Following a short description of the technique, discussions of the theoretical assumptions, data analysis and experimental considerations, in relation to the high-Tc superconductors, are given. We briefly review recent 2D-ACAR experiments on YBa2Cu3O7-x, Bi2Sr2CaCuO8+δ and La2-xSrxCuO4. The 2D-ACAR technique is useful in resolving the band crossings associated with the layers of the superconductors that are preferentially sampled by the positrons. Together with other Fermi surface measurements (namely angle-resolved photoemission), 2D-ACAR can resolve some of the electronic structures of high-Tc cuprate superconductors. In addition, 2D-ACAR measurements of YBa2Cu3O7-x and Bi2Sr2CaCuO8+δ also reveal an interesting temperature dependence in the fine structures, and a change in the positron lifetime in the former.

  8. Standardization of Tc-99 by two methods and participation at the CCRI(II)-K2. Tc-99 comparison.

    PubMed

    Sahagia, M; Antohe, A; Ioan, R; Luca, A; Ivan, C

    2014-05-01

    The work accomplished within the participation at the 2012 key comparison of Tc-99 is presented. The solution was standardized for the first time in IFIN-HH by two methods: LSC-TDCR and 4π(PC)β-γ efficiency tracer. The methods are described and the results are compared. For the LSC-TDCR method, the program TDCR07c, written and provided by P. Cassette, was used for processing the measurement data. The results are 2.1% higher than when applying the TDCR06b program; the higher value, calculated with the software TDCR07c, was used for reporting the final result in the comparison. The tracer used for the 4π(PC)β-γ efficiency tracer method was a standard (60)Co solution. The sources were prepared from the mixture (60)Co+(99)Tc solution and a general extrapolation curve, type: N(βTc-99)/(M)(Tc-99)=f [1-ε(Co-60)], was drawn. This value was not used for the final result of the comparison. The difference between the values of activity concentration obtained by the two methods was within the limit of the combined standard uncertainty of the difference of these two results. © 2013 Published by Elsevier Ltd.

  9. Introduction of an 8-aminooctanoic acid linker enhances uptake of 99mTc-labeled lactam bridge-cyclized α-MSH peptide in melanoma.

    PubMed

    Guo, Haixun; Miao, Yubin

    2014-12-01

    The purpose of this study was to examine the effects of amino acid, hydrocarbon, and polyethylene glycol (PEG) linkers on the melanoma targeting and imaging properties of (99m)Tc-labeled lactam bridge-cyclized HYNIC-linker-Nle-CycMSHhex (hydrazinonicotinamide-linker-Nle-c[Asp-His-DPhe-Arg-Trp-Lys]-CONH2) peptides. Four novel peptides (HYNIC-GGGNle-CycMSHhex, HYNIC-GSGNle-CycMSHhex, HYNIC-PEG2Nle-CycMSHhex, and HYNIC-AocNle-CycMSHhex) were designed and synthesized. The melanocortin-1 receptor binding affinities of the peptides were determined in B16/F1 melanoma cells. The biodistribution of (99m)Tc(ethylenediaminediacetic acid [EDDA])-HYNIC-GGGNle-CycMSHhex, (99m)Tc(EDDA)-HYNIC-GSGNle-CycMSHhex, (99m)Tc(EDDA)-HYNIC-PEG2Nle-CycMSHhex, and (99m)Tc(EDDA)-HYNIC-AocNle-CycMSHhex were determined in B16/F1 melanoma-bearing C57 mice at 2 h after injection to select a lead peptide for further evaluation. The melanoma targeting and imaging properties of (99m)Tc(EDDA)-HYNIC-AocNle-CycMSHhex were further examined because of its high melanoma uptake. The inhibitory concentrations of 50% (IC50) for HYNIC-GGGNle-CycMSHhex, HYNIC-GSGNle-CycMSHhex, HYNIC-PEG2Nle-CycMSHhex, and HYNIC-AocNle-CycMSHhex were 0.7 ± 0.1, 0.8 ± 0.09, 0.4 ± 0.08, and 0.3 ± 0.06 nM, respectively, in B16/F1 melanoma cells. Among these four (99m)Tc-labeled peptides, (99m)Tc(EDDA)-HYNIC-AocNle-CycMSHhex displayed the highest melanoma uptake (22.3 ± 1.72 percentage injected dose/g) at 2 h after injection. (99m)Tc(EDDA)-HYNIC-AocNle-CycMSHhex exhibited high tumor-to-normal-organ uptake ratios except for the kidneys. The tumor-to-kidney uptake ratios of (99m)Tc(EDDA)-HYNIC-AocNle-CycMSHhex were 3.29, 3.63, and 6.78 at 2, 4, and 24 h, respectively, after injection. The melanoma lesions were clearly visualized by SPECT/CT using (99m)Tc(EDDA)-HYNIC-AocNle-CycMSHhex as an imaging probe at 2 h after injection. High melanoma uptake and fast urinary clearance of (99m)Tc(EDDA)-HYNIC-AocNle-CycMSHhex highlighted its

  10. Introduction of an 8-Aminooctanoic Acid Linker Enhances the melanoma uptake of Tc-99m-labeled Lactam Bridge-Cyclized Alpha-MSH Peptide

    PubMed Central

    Guo, Haixun; Miao, Yubin

    2015-01-01

    The purpose of this study was to examine the effects of amino acid, hydrocarbon and polyethylene glycol (PEG) linkers on melanoma targeting and imaging properties of 99mTc-labeled lactam bridge-cyclized HYNIC-linker-Nle-CycMSHhex {hydrazinonicotinamide-linker-Nle-c[Asp-His-DPhe-Arg-Trp-Lys]-CONH2} peptides. Methods four novel peptides {HYNIC-GGGNle-CycMSHhex, HYNIC-GSGNle-CycMSHhex, HYNIC-PEG2Nle-CycMSHhex and HYNIC-AocNle-CycMSHhex} were designed and synthesized. The melanocortin-1 (MC1) receptor binding affinities of the peptides were determined in B16/F1 melanoma cells. The biodistribution of 99mTc(EDDA)-HYNIC-GGGNle-CycMSHhex, 99mTc(EDDA)-HYNIC-GSGNle-CycMSHhex, 99mTc(EDDA)-HYNIC-PEG2Nle-CycMSHhex and 99mTc(EDDA)-HYNIC-AocNle-CycMSHhex were determined in B16/F1 melanoma-bearing C57 mice at 2 h post-injection to select a lead peptide for further evaluation. The melanoma targeting and imaging properties of 99mTc(EDDA)-HYNIC-AocNle-CycMSHhex were further examined because of its high melanoma uptake. Results The IC50 values of HYNIC-GGGNle-CycMSHhex, HYNIC-GSGNle-CycMSHhex, HYNIC-PEG2Nle-CycMSHhex, and HYNIC-AocNle-CycMSHhex were 0.7 ± 0.1, 0.8 ± 0.09, 0.4 ± 0.08, and 0.3 ± 0.06 nM in B16/F1 melanoma cells, respectively. Among these four 99mTc-labeled peptides, 99mTc(EDDA)-HYNIC-AocNle-CycMSHhex displayed the highest melanoma uptake (22.3 ± 1.72% ID/g) at 2 h post-injection. 99mTc(EDDA)-HYNIC-AocNle-CycMSHhex exhibited high tumor to normal organ uptake ratios except for the kidneys. The tumor/kidney uptake ratios of 99mTc(EDDA)-HYNIC-AocNle-CycMSHhex were 3.29, 3.63 and 6.78 at 2, 4 and 24 h post-injection. The melanoma lesions were clearly visualized by single photon emission computed tomography (SPECT)/CT using 99mTc(EDDA)-HYNIC-AocNle-CycMSHhex as an imaging probe at 2 h post-injection. Conclusion High melanoma uptake and fast urinary clearance of 99mTc(EDDA)-HYNIC-AocNle-CycMSHhex highlighted its potential for metastatic melanoma detection in the future

  11. Polaron theory of high- Tc superconductors

    NASA Astrophysics Data System (ADS)

    Alexandrov, A. S.

    1989-05-01

    It is shown that the ordinary electron-phonon interaction can produce a high Tc as a result of the polaron narrowing of the band, which is not considered by the traditional theory of strong-coupling superconductors based on Migdal-Eliashberg equations, which are violated even in the range of moderate values λ ⪖1. Numerous experimental data are discussed which seem to favour a phonon-mediated attraction, polaron mass enhancement, narrow band and nonadiabatic motion of carriers and charged Bose-like excitations in high Tc metallic oxides.

  12. 18F-Fluorocholine PET/CT in the assessment of primary hyperparathyroidism compared with 99mTc-MIBI or 99mTc-tetrofosmin SPECT/CT: a prospective dual-centre study in 100 patients.

    PubMed

    Beheshti, Mohsen; Hehenwarter, Lukas; Paymani, Zeinab; Rendl, Gundula; Imamovic, Larisa; Rettenbacher, Rupert; Tsybrovskyy, Oleksiy; Langsteger, Werner; Pirich, Christian

    2018-03-08

    In this prospective study we compared the accuracy of 18 F-fluorocholine PET/CT with that of 99m Tc-MIBI or 99m Tc-tetrofosmin SPECT/CT in the preoperative detection of parathyroid adenoma in patients with primary hyperparathyroidism. We also assessed the value of semiquantitative parameters in differentiating between parathyroid hyperplasia and adenoma. Both 18 F-fluorocholine PET/CT and 99m Tc-MIBI/tetrofosmin SPECT/CT were performed in 100 consecutive patients with biochemical evidence of primary hyperparathyroidism. At least one abnormal focus on either 18 F-fluorocholine or 99m Tc-MIBI/tetrofosmin corresponding to a parathyroid gland or ectopic parathyroid tissue was considered as a positive finding. In 76 patients with positive findings on at least one imaging modality, surgical exploration was performed within 6 months, and the results were related to histopathological findings and clinical and laboratory findings at 3-6 months as the standard of truth. In 24 patients, no surgery was performed: in 18 patients with positive imaging findings surgery was refused or considered risky, and in 6 patients imaging was negative. Therefore, data from 82 patients (76 undergoing surgery, 6 without surgery) in whom the standard of truth criteria were met, were used in the final analysis. All patients showed biochemical evidence of primary hyperparathyroidism with a mean serum calcium level of 2.78 ± 0.34 mmol/l and parathormone (PTH) level of 196.5 ± 236.4 pg/ml. The study results in 76 patients with verified histopathology and 3 patients with negative imaging findings were analysed. Three of six patients with negative imaging showed normalized serum PTH and calcium levels on laboratory follow-up at 3 and 6 months, and the results were considered true negative. In a patient-based analysis, the detection rate with 18 F-fluorocholine PET/CT was 93% (76/82), but was only 61% (50/82) with 99m Tc-MIBI/tetrofosmin SPECT/CT. In a lesion-based analysis, the

  13. Imaging human melanoma using a novel Tc-99m-labeled lactam bridge-cyclized alpha-MSH peptide.

    PubMed

    Liu, Liqin; Xu, Jingli; Yang, Jianquan; Feng, Changjian; Miao, Yubin

    2016-10-01

    In this study, the human melanoma targeting property of (99m)Tc(EDDA)-HYNIC-AocNle-CycMSHhex {hydrazinonicotinamide-8-aminooctanoic acid-Nle-c[Asp-His-DPhe-Arg-Trp-Lys]-CONH2} was determined in M21 human melanoma-xenografts to demonstrate its potential for human melanoma imaging. The IC50 value of HYNIC-AocNle-CycMSHhex was 0.48±0.01nM in M21 human melanoma cells (1281receptors/cell). The M21 human melanoma uptake of (99m)Tc(EDDA)-HYNIC-AocNle-CycMSHhex was 4.03±1.25, 3.26±1.23 and 3.36±1.48%ID/g at 0.5, 2 and 4h post-injection, respectively. Approximately 92% of injected dose cleared out the body via urinary system at 2h post-injection. (99m)Tc(EDDA)-HYNIC-AocNle-CycMSHhex showed high tumor/blood, tumor/muscle and tumor/skin uptake ratios after 2h post-injection. The M21 human melanoma-xenografted tumor lesions were clearly visualized by SPECT/CT using (99m)Tc(EDDA)-HYNIC-AocNle-CycMSHhex as an imaging probe at 2h post-injection. Overall, (99m)Tc(EDDA)-HYNIC-AocNle-CycMSHhex exhibited favorable human melanoma imaging property, highlighting its potential as an imaging probe for human metastatic melanoma detection. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. System Concepts for Children via LEGO TC logo.

    ERIC Educational Resources Information Center

    Gorbunov, Andrei L.

    1994-01-01

    Discussion of knowledge constructionism focuses on LEGO TC logo, a program that permits control of LEGO toys by means of a computer. A project for 9- and 10-year-old students that uses LEGO TC logo to develop concepts related to automatic control systems is explained. (three references) (LRW)

  15. Fe(II)- and Sulfide-Facilitated Reduction of 99Tc(VII)O4- in Microbially Reduced Hyporheic Zone Sediments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Ji-Hoon; Zachara, John M.; Fredrickson, Jim K.

    Redox-reactive, biogeochemical phases generated by reductive microbial activity in hyporheic zone sediments from a dynamic groundwater-river interaction zone were evaluated for their ability to reduce soluble pertechnetate [99Tc(VII)O4-] to less soluble Tc(IV). The sediments were bioreduced by indigenous microorganisms that were stimulated by organic substrate addition in synthetic groundwater with or without sulfate. In most treatments, 20 µmol L-1 initial aqueous Tc(VII) was reduced to near or below detection (3.82×10-9 mol L-1) over periods of days to months in suspensions of variable solids concentrations. Native sediments containing significant lithogenic Fe(II) in various phases were, in contrast, unreactive with Tc(VII). Themore » reduction rates in the bioreduced sediments increased with increases in sediment mass, in proportion to weak acid-extractable Fe(II) and sediment-associated sulfide (AVS). The rate of Tc(VII) reduction was first order with respect to both aqueous Tc(VII) concentration and sediment mass, but correlations between specific reductant concentrations and reaction rate were not found. X-ray microprobe measurements revealed a strong correlation between Tc hot spots and Fe-containing mineral particles in the sediment. However, only a portion of Fe-containing particles were Tc-hosts. The Tc-hot spots displayed a chemical signature (by EDXRF) similar to pyroxene. The application of autoradiography and electron microprobe allowed further isolation of Tc-containing particles that were invariably found to be ca 100 µm aggregates of primary mineral material embedded within a fine-grained phyllosilicate matrix. EXAFS spectroscopy revealed that the Tc(IV) within these were a combination of a Tc(IV)O2-like phase and Tc(IV)-Fe surface clusters, with a significant fraction of a TcSx-like phase in sediments incubated with SO42-. AVS was implicated as a more selective reductant at low solids concentration even though its concentration was below

  16. Fe(II)- and sulfide-facilitated reduction of 99Tc(VII)O4- in microbially reduced hyporheic zone sediments

    NASA Astrophysics Data System (ADS)

    Lee, Ji-Hoon; Zachara, John M.; Fredrickson, James K.; Heald, Steve M.; McKinley, James P.; Plymale, Andrew E.; Resch, Charles T.; Moore, Dean A.

    2014-07-01

    Redox-reactive, biogeochemical phases generated by reductive microbial activity in hyporheic zone sediments from a dynamic groundwater-river interaction zone were evaluated for their ability to reduce soluble pertechnetate [99Tc(VII)O4-] to less soluble Tc(IV). The sediments were bioreduced by indigenous microorganisms that were stimulated by organic substrate addition in synthetic groundwater with or without sulfate. In most treatments, 20 μmol L-1 initial aqueous Tc(VII) was reduced to near or below detection (3.82 × 10-9 mol L-1) over periods of days to months in suspensions of variable solids concentrations. Native sediments containing significant lithogenic Fe(II) in various phases were, in contrast, unreactive with Tc(VII). The reduction rates in the bioreduced sediments increased with increases in sediment mass, in proportion to weak acid-extractable Fe(II) and sediment-associated sulfide (AVS). The rate of Tc(VII) reduction was first order with respect to both aqueous Tc(VII) concentration and sediment mass, but correlations between specific reductant concentrations and reaction rate were not found. X-ray microprobe measurements revealed a strong correlation between Tc hot spots and Fe-containing mineral particles in the sediment. However, only a portion of Fe-containing particles were Tc-hosts. The Tc-hot spots displayed a chemical signature (by EDXRF) similar to pyroxene. The application of autoradiography and electron microprobe allowed further isolation of Tc-containing particles that were invariably found to be ca 100 μm aggregates of primary mineral material embedded within a fine-grained phyllosilicate matrix. EXAFS spectroscopy revealed that the Tc(IV) within these were a combination of a Tc(IV)O2-like phase and Tc(IV)-Fe surface clusters, with a significant fraction of a TcSx-like phase in sediments incubated with SO42-. AVS was implicated as a more selective reductant at low solids concentration even though its concentration was below that

  17. NEUTRON SCATTERING STUDY OF THE HIGH-Tc SUPERCONDUCTING SYSTEM YBa2Cu3O6+x

    NASA Astrophysics Data System (ADS)

    Rossat-Mignod, J.; Regnault, L. P.; Bourges, P.; Burlet, P.; Vettier, C.; Henry, J. Y.

    The following sections are included: * Introduction * The neutron scattering technique * Phase diagrams of high-Tc superconductors * The undoped AF-doped * The doped AF-state * The weakly-doped metallic state * The heavily-doped metallic state * The overdoped metallic state * Discussion and concluding remarks * Acknowledgements * References

  18. 99mTc-MAA/ 90Y-Bremsstrahlung SPECT/CT after simultaneous Tc-MAA/90Y-microsphere injection for immediate treatment monitoring and further therapy planning for radioembolization.

    PubMed

    Ahmadzadehfar, Hojjat; Sabet, Amir; Muckle, Marianne; Wilhelm, Kai; Reichmann, Karl; Biersack, Hans-Jürgen; Ezziddin, Samer

    2011-07-01

    An angiographic evaluation combined with (99m)Tc-macroaggregated albumin (Tc-MAA) scanning should precede the treatment of any selected candidates for radioembolization (RE) of the liver. If the tumours in one liver lobe have not been targeted in the test angiogram, it should be repeated. However, in a few cases treatment of one liver lobe or at least some segments is safe and feasible and performing a repeated test angiogram with Tc-MAA (Re-MAA) in a separate session leads to more radiation exposure and could be time consuming. Our aim was to evaluate the feasibility of concurrent RE of a part of the liver and therapy planning for another region by simultaneous injection of the Tc-MAA and (90)Y-microspheres in two different locations in the therapy session. Tc-MAA and bremsstrahlung (BS) single photon emission computed tomography (SPECT)/CT were performed separately in an effort to distinguish between the distributions of these two different radiopharmaceuticals. RE was combined with a simultaneous second test angiogram of another lobe or segments in the same session in six patients [44-70 years; five women (83%)]. Five patients suffered from colorectal carcinoma (CRC) and one from ovarian cancer. Tc-MAA and BS SPECT/CT were performed for all cases. Post-therapeutic Tc-MAA SPECT/CT showed in all patients only the distribution of Tc-MAA without any detectable BS. Evaluation of (90)Y-microsphere distribution was not always possible in the post-therapeutic BS scan performed 24 h later due to remaining Tc-MAA radiation. However, scans performed at 48 h post-intervention no longer showed any Tc-MAA "contamination". Combining RE and Re-MAA is feasible in appropriately selected patients.

  19. Supine lung clearance of Tc-99m DTPA and HMPAO aerosols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chia-Hung Kao; Hui-Tzu Lin; Shu-Ling Yu

    1995-07-01

    The speed of Tc-99m DTPA/HMPAO radioaerosol clearance from the lungs that is represented as a slope from lungs to blood was measured in 23 male normal controls using commercial lung radioaerosol delivery units in the supine position in order to avoid the influences of gravity. The right lung was selected and three regions of interest were created for equal subdivisions of the upper, middle, and lower third. The results show that the clearance of Tc-99m DTPA/HMPAO aerosols in the upper lung is lowest. The difference between upper and lower lungs for Tc-99m DTPA/HMPAO aerosol clearances are significant. The clearance ofmore » Tc-99m DTPA aerosols was significantly faster than those of Tc-99m HMPAO in any region. The authors conclude that, although the effect of gravity disappears in the supine position in our study, the differences of aerosol clearance in different regions are still significant. Lipophilic Tc-99m HMPAO aerosols were slower than those of hydrophilic Tc-99m DTPA, which suggests there are at least two different mechanisms. 22 refs., 2 figs., 1 tab.« less

  20. Association of APOA5 -1131T>C polymorphism and serum lipid levels in patients with type 2 diabetes.

    PubMed

    Celap, Ivana; Simundic, Ana-Maria; Nikolac, Nora; Kackov, Sanja; Katalinic, Darko

    2013-10-01

    Significant abnormalities in lipid metabolism are frequently present in patients with type 2 diabetes mellitus (T2DM). Hypertriglyceridemia, a highly proatherogenic state, is associated with increased risk of coronary artery disease. Genetic polymorphism APOA5 -1131T>C has been recognized as a significant contributor to hypertriglyceridemia in both healthy and diabetic populations. The aim of the study was to investigate the association of APOA5 -1131T>C polymorphism with the serum levels of triglycerides, total cholesterol, high-density lipoprotein (HDL) cholesterol, and low-density lipoprotein (LDL) cholesterol in patients with T2DM. In total, 234 DNA samples from patients with T2DM were genotyped using the PCR-RFLP method. Serum lipid levels were measured using standard laboratory methods. Obtained APOA5 -1131T>C genotype frequencies were 89% (T/T) and 11% (T/C+C/C). There was no significant association between APOA5 -1131T>C genotypes and triglyceride levels (1.90 mM [1.32-2.74] vs. 1.78 mM [1.54-3.05] for T/T vs. T/C+C/C genotype; p=0.553), HDL cholesterol levels (1.30 mM [1.10-1.40] vs. 1.30 mM [1.05-1.40] for T/T vs. T/C+C/C; p=0.534), and LDL cholesterol levels (3.1 mM [2.3-3.8] vs. 3.0 mM [2.2-3.5] for T/T vs. T/C+C/C; p=0.313). Our results suggest that hypertriglyceridemia in patients with T2DM is not likely to be associated with the APOA5 -1131T>C polymorphism.