Sample records for td-nickel chromium

  1. Deformation and annealing response of TD-nickel chromium sheet

    NASA Technical Reports Server (NTRS)

    Kane, R. D.; Ebert, L. J.

    1973-01-01

    The deformation and annealing response of TD-nickel chromium (TD-NiCr) 0.1 inch thick sheet was examined using various cold-rolling and annealing treatments. Upon annealing (above 816 C (1500 F), the as-received material was converted from an initially ultra-fine grain size (average grain dimension 0.51 micron) to a large grain structure. Increases in grain size by a factor of 100 to 200 were observed for this transformation. However, in those material states where the large grain transformation was absent, a fine grain recrystallized structure formed upon annealing (above 732 C (1350 F)). The deformation and annealing response of TD-NiCr sheet was evaluated with respect to the processing related variables as mode and severity of deformation and annealing temperature. Results indicate that the large grain transformation, classical primary recrystallization occurs. Using selected materials produced during the deformation and annealing study, the elevated temperature tensile properties of TD-NiCr sheet were examined in the temperature range 593 C (1100 F) to 1093 C (2000 F). It was observed that the elevated temperature tensile properties of TD-NiCr sheet could be optimized by the stabilization of a large grain size in this material using the cold working and/or annealing treatments developed during the present investigation.

  2. Cyclic creep and fatigue of TD-NiCr (thoria-dispersion-strengthened nickel-chromium), TD-Ni, and NiCr sheet at 1200 C

    NASA Technical Reports Server (NTRS)

    Hirschberg, M. H.; Spera, D. A.; Klima, S. J.

    1972-01-01

    The resistance of thin TD-NiCr sheet to cyclic deformation was compared with that of TD-Ni and a conventional nickel-chromium alloy. Strains were determined by a calibration technique which combines room-temperature strain gage and deflection measurements with high-temperature deflection measurements. Analyses of the cyclic tests using measured tensile and creep-rupture data indicated that the TD-NiCr and NiCr alloy specimens failed by a cyclic creep mechanism. The TD-Ni specimens, on the other hand, failed by a fatigue mechanism.

  3. Elevated temperature deformation of thoria dispersed nickel-chromium

    NASA Technical Reports Server (NTRS)

    Kane, R. D.; Ebert, L. J.

    1974-01-01

    The deformation behavior of thoria nickel-chromium (TD-NiCr) was examined over the temperature range 593 C (1100 F) to 1260 C (2300 F) in tension and compression and at 1093 C (2000 F) in creep. Major emphasis was placed on: (1) the effects of the material and test related variables (grain size, temperature, stress and strain rate) on the deformation process; and (2) the evaluation of single crystal TD-NiCr material produced by a directional recrystallization process. Elevated temperature yield strength levels and creep activation enthalpies were found to increase with increasing grain size reaching maximum values for the single crystal TD-NiCr. Stress exponent of the steady state creep rate was also significantly higher for the single crystal TD-NiCr as compared to that determined for the polycrystalline materials. The elevated temperature deformation of TD-NiCr was analyzed in terms of two concurrent, parallel processes: diffusion controlled grain boundary sliding, and dislocation motion.

  4. Development of dispersion strengthened nickel-chromium alloy (Ni-Cr-ThO2) sheet for space shuttle vehicles, part 2

    NASA Technical Reports Server (NTRS)

    Klingler, L. J.; Weinberger, W. R.; Bailey, P. G.; Baranow, S.

    1972-01-01

    Two dispersion strengthened nickel base alloy systems were developed for use at temperatures up to 1204 C(2200 F); TD nickel chromium (TDNiCr) and TD nickel chromium aluminum (TDNiCrA1). They are considered candidate materials for use on the thermal protection systems of the space shuttle and for long term use in aircraft gas turbine engine applications. Improved manufacturing processes were developed for the fabrication of TDNiCr sheet and foil to specifications. Sheet rolling process studies and extrusion studies were made on two aluminum containing alloys: Ni-16%Cr-3.5%A1-2%ThO2 and Ni-16%Cr-5.0%A12%ThO2. Over 1600 kg.(3500 lb.) of plate, sheet, foil, bar and extrusion products were supplied to NASA Centers for technology studies.

  5. Exploratory study of friction welds in Udimet 700 and TD-Nickel bar

    NASA Technical Reports Server (NTRS)

    Moore, T. J.

    1971-01-01

    Friction welded butt joints were made in both Udimet 700 and TD-Nickel bar. Also, dissimilar metal friction welds were made between these materials. Friction welding of Udimet 700 shows great promise because the welds were found to be as strong as the parent metal in stress rupture and tensile tests at 760 and 980 C. The weld line was not detectable metallographically in the heat treated condition. Friction welding for TD-Nickel, however, holds little if any promise. TD-Nickel friction weldments could support only 9 percent as much stress as the base metal for a 10-hour stress-rupture life at 1090 C. Dissimilar Udimet 700/TD-Nickel friction welds could sustain only 15 percent as much stress as the TD-Nickel parent metal for a 10-hour rupture life at 930 C.

  6. Deformation and annealing response of TD-nickel chromium

    NASA Technical Reports Server (NTRS)

    Kane, R. D.; Ebert, L. J.

    1975-01-01

    The recrystallization and grain growth processes occurring in TD-NiCr were examined with respect to deformation severity, annealing time, and temperature. Results indicated that two different annealing responses of TD-NiCr are possible, depending on the initial state and processing history prior to annealing. As-received sheet showed a dramatic increase in grain size with decreasing annealing temperature, whereas sheet prior-annealed at 1316 C for 1 hr exhibited very little variation with subsequent annealing temperature.

  7. 40 CFR Appendix Xii to Part 266 - Nickel or Chromium-Bearing Materials that may be Processed in Exempt Nickel-Chromium Recovery...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... sweepings Air filters Electroplating bath filters Wastewater filter media Wood pallets Disposable clothing... cartridge filters Paper hand towels B. Exempt Nickel or Chromium-Bearing Materials when Generated by Any... Nickel, chromium, and iron catalysts Nickel-cadmium and nickel-iron batteries Filter cake from wet...

  8. 40 CFR Appendix Xii to Part 266 - Nickel or Chromium-Bearing Materials that may be Processed in Exempt Nickel-Chromium Recovery...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... sweepings Air filters Electroplating bath filters Wastewater filter media Wood pallets Disposable clothing... cartridge filters Paper hand towels B. Exempt Nickel or Chromium-Bearing Materials when Generated by Any... Nickel, chromium, and iron catalysts Nickel-cadmium and nickel-iron batteries Filter cake from wet...

  9. 40 CFR Appendix Xii to Part 266 - Nickel or Chromium-Bearing Materials that may be Processed in Exempt Nickel-Chromium Recovery...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... sweepings Air filters Electroplating bath filters Wastewater filter media Wood pallets Disposable clothing... cartridge filters Paper hand towels B. Exempt Nickel or Chromium-Bearing Materials when Generated by Any... Nickel, chromium, and iron catalysts Nickel-cadmium and nickel-iron batteries Filter cake from wet...

  10. 40 CFR Appendix Xii to Part 266 - Nickel or Chromium-Bearing Materials that may be Processed in Exempt Nickel-Chromium Recovery...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... sweepings Air filters Electroplating bath filters Wastewater filter media Wood pallets Disposable clothing... cartridge filters Paper hand towels B. Exempt Nickel or Chromium-Bearing Materials when Generated by Any... Nickel, chromium, and iron catalysts Nickel-cadmium and nickel-iron batteries Filter cake from wet...

  11. 40 CFR Appendix Xii to Part 266 - Nickel or Chromium-Bearing Materials that may be Processed in Exempt Nickel-Chromium Recovery...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... sweepings Air filters Electroplating bath filters Wastewater filter media Wood pallets Disposable clothing... cartridge filters Paper hand towels B. Exempt Nickel or Chromium-Bearing Materials when Generated by Any... Nickel, chromium, and iron catalysts Nickel-cadmium and nickel-iron batteries Filter cake from wet...

  12. Elevated temperature deformation of TD-nickel base alloys

    NASA Technical Reports Server (NTRS)

    Petrovic, J. J.; Kane, R. D.; Ebert, L. J.

    1972-01-01

    Sensitivity of the elevated temperature deformation of TD-nickel to grain size and shape was examined in both tension and creep. Elevated temperature strength increased with increasing grain diameter and increasing L/D ratio. Measured activation enthalpies in tension and creep were not the same. In tension, the internal stress was not proportional to the shear modulus. Creep activation enthalpies increased with increasing L/D ratio and increasing grain diameter, to high values compared with that of the self diffusion enthalpy. It has been postulated that two concurrent processes contribute to the elevated temperature deformation of polycrystalline TD-nickel: (1) diffusion controlled grain boundary sliding, and (2) dislocation motion.

  13. Nickel and chromium toxicity of serpentine soils in Southern Rhodesia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Soane, B.D.; Saunder, D.H.

    1959-01-01

    Very high nickel and chromium contents were found in many infertile soils derived from or near serpentine rocks in Southern Rhodesia. Data are given for nine typical soils. Various plant growth abnormalities are described for maize, tobacco, and oats grown on these soils. Plant contents of nickel and chromium are given. Exchangeable nickel showed a close correlation with the nickel content of indigenous grasses from the same sites. Attempts to measure available chromium were unsuccessful. Symptoms of maize and tobacco grown with various concentrations of chromium and nickel in sand culture were compared with symptoms obtained in the field. Itmore » is concluded that nickel toxicity is the cause of the acute infertility of some of the soils tested. On one soil the toxicity was so intense that raising the pH to 8.2 with calcium carbonate did not eliminate nickel uptake or toxicity symptoms in oats. Chromium toxicity appears to be associated with the infertility of other soils, but it is complicated by possible interaction between chromium and phosphorus and calcium in the soil-plant system.« less

  14. Electrodeposition of amorphous ternary nickel-chromium-phosphorus alloy

    DOEpatents

    Guilinger, Terry R.

    1990-01-01

    Amorphous ternary nickel-chromium-phosphorus alloys are electrodeposited from a bath comprising a nickel salt, a chromium salt, a phosphorus source such as sodium hypophosphite, a complexing agent for the nickel ions, supporting salts to increase conductivity, and a buffering agent. The process is carried out at about room temperature and requires a current density between about 20 to 40 A/dm.sup.2.

  15. Metallographic examination of TD-nickel base alloys. [thermal and chemical etching technique evaluation

    NASA Technical Reports Server (NTRS)

    Kane, R. D.; Petrovic, J. J.; Ebert, L. J.

    1975-01-01

    Techniques are evaluated for chemical, electrochemical, and thermal etching of thoria dispersed (TD) nickel alloys. An electrochemical etch is described which yielded good results only for large grain sizes of TD-nickel. Two types of thermal etches are assessed for TD-nickel: an oxidation etch and vacuum annealing of a polished specimen to produce an etch. It is shown that the first etch was somewhat dependent on sample orientation with respect to the processing direction, the second technique was not sensitive to specimen orientation or grain size, and neither method appear to alter the innate grain structure when the materials were fully annealed prior to etching. An electrochemical etch is described which was used to observe the microstructures in TD-NiCr, and a thermal-oxidation etch is shown to produce better detail of grain boundaries and to have excellent etching behavior over the entire range of grain sizes of the sample.

  16. Genotoxic Effects Due to Exposure to Chromium and Nickel Among Electroplating Workers.

    PubMed

    El Safty, Amal Mohamed Kamal; Samir, Aisha Mohamed; Mekkawy, Mona Kamal; Fouad, Marwa Mohamed

    Using chromium and nickel for electroplating is important in many industries. This process induces variable adverse health effects among exposed workers. The aim of this study is to detect the genotoxic effects of combined exposure to chromium and nickel among electroplating workers. This study was conducted on 41 male workers occupationally exposed to chromium and nickel in the electroplating section of a factory compared to 41 male nonexposed individuals, where full history and clinical examination were performed. Laboratory investigations included measurement of serum chromium, nickel, 8-hydroxydeoxyguanosine (8-OHdG), and micronuclei were measured in buccal cells. In exposed workers, serum chromium ranged from 0.09 to 7.20 µg/L, serum nickel ranged from 1.20 to 28.00 µg/L, serum 8-OHdG ranged from 1.09 to12.60 ng/mL, and these results were statistically significantly increased compared to nonexposed group ( P < 0.001). Electroplaters showed higher frequencies of micronuclei in buccal cells when compared to nonexposed (ranged from 20.00 to 130.00 N/1,000 versus 2.00 to 28.00 N/1,000; P < 0.001). Linear regression models were done to detect independent predictors of 8-OHdG and micronucleus test by comparing exposed and nonexposed groups. The model found that exposure to chromium and nickel increases serum 8-OHdG by 4.754 (95% confidence interval [CI]: 3.54-5.96). The model found that exposure to chromium and nickel increases micronucleus by 35.927 (95% CI: 28.517-43.337). Serum 8-OHdG and micronucleus test in buccal cells were increased with combined exposure to chromium and nickel. The current research concluded that workers exposed to nickel and chromium in electroplating industry are at risk of significant cytogenetic damage.

  17. An electron microscopy examination of primary recrystallization in TD-nickel.

    NASA Technical Reports Server (NTRS)

    Petrovic, J. J.; Ebert, L. J.

    1972-01-01

    Primary recrystallization in TD-nickel 1 in. bar has previously been regarded as the process by which the initial fine grain structure is converted to a coarse grain size (increases in grain size by 500 times) under suitable deformation and annealing conditions. This process is dependent on deformation mode. While it occurs readily after rolling transverse to the bar axis and annealing (800 C), it is completely inhibited by longitudinal rolling and swaging deformations, even for very high (1320 C) annealing temperatures. A transmission electron microscopy examination of deformation and annealing substructures indicates that primary recrystallization in TD-nickel 1 in. bar actually occurs on the sub-light optical level, to produce a grain structure similar in size to the initial fine grained state.

  18. Development of dispersion strengthened nickel-chromium alloy (Ni-Cr-Th-O2) sheet for space shuttle vehicles, part 1

    NASA Technical Reports Server (NTRS)

    Klingler, L. J.; Weinberger, W. R.; Bailey, P. G.; Baranow, S.

    1971-01-01

    A dispersion-strengthened alloy, TD nickel chromium (TDNiCr) is being developed for use on the thermal protection system of the space shuttle at temperatures up to 1204 C(2200 F). Manufacturing processes were developed for the fabrication of sheet and foil to specifications. The addition of aluminum to the basic TDNiCr composition provides outstanding oxidation resistance up to 1260 C(2300 F); aluminum levels of 2 to 4% are considered optimum for space shuttle application.

  19. [Study on content of nickel in saliva released from the nickel-chromium and the nickel-chromium-titanium porcelain alloy].

    PubMed

    Wang, Wen-Jie; Zhang, Tai-Qiang; Wei, Hong

    2010-02-01

    The purpose of the study was to investigate the content of nickel (Ni) ion in patients' saliva after wearing the porcelain-fused-to nickel-chromium (Ni-Cr) crown or the porcelain-fused-to nickel-chromium-titanium(Ni-Cr-Ti) crown. 50 patients who had one molar or premolar needed repairing were selected and divided into two groups randomly. Patients in one group were fabricated with porcelain-fused-to Ni-Cr crown and the patients in the other group were fabricated with porcelain-fused-to Ni-Cr-Ti crown. Collect the patients' saliva before wearing, 1 week, 3 months, and 6 months after wearing. The content of Ni ion in saliva was detected by inductively coupled plasma mass spectrometry (ICP-MS). The content of Ni ion in both groups increased at the first week, and go back after 6 months. There were no significant differences before wearing, 1 week, 3 months, and 6 months after wearing. There were no significant differences between the two groups. Wearing the porcelain-fused-to Ni-Cr crown or the porcelain-fused-to Ni-Cr-Ti crown has no significant influence on the content of Ni ion in saliva.

  20. Chromium-doped Raney nickel catalyst for hydrogen electrodes in alkaline fuel cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kenjo, T.

    Raney nickel is a relatively inexpensive and highly active nonnoble metal catalyst for hydrogen electrodes in alkaline fuel cells. Mund et al. (1977) have found that its catalytic activity is increased by doping involving transition metals, such a titanum, iron, and molybdenum. The present investigation is concerned with the preparation of hydrogen electrodes catalyzed with chromium-doped Raney nickel and the measurement of their polarization characteristics. On the basis of the obtained results, it is concluded that chromium is a good dopant for Raney nickel which is employed for hydrogen electrodes. Chromium improves and stabilizes the polarization characteristics of Raney nickelmore » electrodes. It is found that chromium-doped Raney nickel is more active than the titanium-doped catalyst. 6 references.« less

  1. Contribution to chromium and nickel enrichment during cooking of foods in stainless steel utensils.

    PubMed

    Accominotti, M; Bost, M; Haudrechy, P; Mantout, B; Cunat, P J; Comet, F; Mouterde, C; Plantard, F; Chambon, P; Vallon, J J

    1998-06-01

    Nickel ingestion can cause exacerbation of dermatitis in patients who are already nickel-sensitive; Chromium (Cr VI) is the 2nd allergen, after nickel. However, stainless steel is widely used in home cookware. In this study, we determined nickel and chromium levels by atomic absorption spectrometry in 11 habitual menus cooked in different grades of stainless steel utensils. We noted a great difference in nickel and chromium intake depending on the menu, and a significant difference between the glass and stainless steel saucepans, but this was very low compared with the levels of nickel and chromium contained in the menus; mean intakes of these elements were under the tolerable daily intake (TDI) recommended by the World Health Organization. Hence, there is no advantage for nickel-sensitive patients in switching to materials other than stainless steel, provided that this is of good quality.

  2. CHROMIUM ELECTROANALYSIS AT SCREEN PRINTED ELECTRODE MODIFIED BY THIN FILMS OF NICKEL

    EPA Science Inventory

    A rapid and potentially cost-effective electrochemical method is reported for analysis of chromium (VI) and Chromium(III) using a nickel modified screen printed carbon ink electrode. Electrochemical characteristics of nickel modified electrode as well voltammetric behavior f...

  3. Nickel-chromium-silicon brazing filler metal

    DOEpatents

    Martini, Angelo J.; Gourley, Bruce R.

    1976-01-01

    A brazing filler metal containing, by weight percent, 23-35% chromium, 9-12% silicon, a maximum of 0.15% carbon, and the remainder nickel. The maximum amount of elements other than those noted above is 1.00%.

  4. Semen quality of Indian welders occupationally exposed to nickel and chromium.

    PubMed

    Danadevi, K; Rozati, Roya; Reddy, P P; Grover, Paramjit

    2003-01-01

    The semen quality of 57 workers from a welding plant in South India and 57 controls was monitored. Blood nickel and chromium concentrations were determined by ICP-MS. Analysis of semen samples was performed in accordance with World Health Organization criteria. The blood level of nickel and chromium for the 28 exposed workers was 123.3 +/- 35.2 and 131.0 +/- 52.6 microg/l, resepctively, which was significantly higher than the 16.7 +/- 5.8 and 17.4 +/- 8.9 microg/l for the control group (n=27). Sperm concentrations of exposed workers were 14.5 +/- 24.0 millions/ml and those of the control group were 62.8 +/- 43.7 millions/ml. Rapid linear sperm motility was decreased in exposed workers compared to controls. There was a significant positive correlation between the percentage of tail defects and blood nickel concentration in exposed workers. The sperm concentration showed a negative correlation with blood chromium content in workers. More abnormal characteristics were found in the semen of exposed workers. Semen abnormalities correlated with the number of years of exposure to welding fumes containing nickel and chromium.

  5. Serum levels of nickel and chromium after instrumented posterior spinal arthrodesis.

    PubMed

    Kim, Young-Jo; Kassab, Farid; Berven, Sigurd H; Zurakowski, David; Hresko, M Timothy; Emans, John B; Kasser, James R

    2005-04-15

    Cross-sectional study of 37 patients to measure serum levels of nickel and chromium after posterior spinal arthrodesis using stainless steel implants. To investigate the relationship between factors such as age, gender, pain, time from surgery, length of arthrodesis, and level of arthrodesis to serum metal ion levels after instrumented spinal arthrodesis. Measurable levels of metal ions in the serum can be detected after the use of stainless steel implants. There is some evidence to suggest that long-term exposure can potentially be toxic. Posterior spinal arthrodesis with stainless steel implants is a common procedure to treat spinal deformity in the adolescent population; however, the extent of metal ion exposure after posterior spinal arthrodesis is unknown. Patients that underwent posterior instrumented spinal arthrodesis with more than 6 months follow-up were recruited for this study. Patients with altered neurologic function were excluded. Serum levels of nickel and chromium were measured using inductively coupled plasma mass spectrometry. Pain was assessed using the Oswestry questionnaire. Spine radiographs were used to look for evidence of pseudarthrosis. Forty-five patients were approached, and 37 agreed to the questionnaire and blood test. Ten patients were men and 27 were women. Mean age at surgery was 14 years with mean follow-up of 6 years. Statistical correlations between serum metal ion levels and age at surgery, time from surgery, gender, number of segments fused, spinal instrument interfaces, pain, and instrumentation type were assessed. Abnormally high levels of nickel and chromium above normal levels (0.3 ng/mL for nickel, 0.15 ng/mL for chromium) could be detected in serum after posterior spinal arthrodesis using stainless steel implants. There was a significant inverse correlation between serum nickel (r = -0.61, P < 0.001) and chromium (r = -0.64, P < 0.001) levels and time from surgery. When patients were grouped based on lengths of time from

  6. Migration studies of nickel and chromium from ceramic and glass tableware into food simulants.

    PubMed

    Szynal, Tomasz; Rebeniak, Małgorzata; Mania, Monika

    In addition to the release of lead and cadmium from ceramic and glass vessels, (acceptable limits being set by the EU 84/500/EC Directive), other harmful metals can migrate, such as nickel and chromium. Permissible migration limits for these latter metals however have not yet been set in the EU legislation. Both the toxic properties of nickel and chromium and the measures taken by the European Commission Working Group on Food Contact Materials for verifying permissible migration limits for lead, cadmium and other metals from ceramics have acted as drivers for studies on nickel and chromium release from ceramic and glass tableware. To investigate the migration of nickel and chromium into food simulants from ceramic and glassware, available on the Polish market, which are intended for coming into contact with food. Potential consumer exposure can thereby be estimated from the release of these elements into food. Tableware consisted of ceramics and glass vessels generally available on the domestic market, with inner surfaces being mainly coloured and with rim decorations. Migration of nickel and chromium studied from the ceramics was carried out in 4% acetic acid (24 ± 0.5 hrs at 22 ± 2°C), whilst that from glassware in 4% acetic acid (24 ± 0.5 hrs at 22 ± 2°C) and 0.5% citric acid (2 ± 0.1 hrs at 70 ± 2°C). The concentrations of metals which had migrated into the test solutions were measured by using flame atomic absorption spectrometry (FAAS). This analytical procedure had been previously validated by measuring nickel and chromium released into food simulants from ceramic and glass tableware where working ranges, detection limits, quantification limits, repeatability, accuracy, mean recovery and uncertainty were established. Migration of nickel and chromium was measured from 172 ceramic and 52 and glass vessels samples, with all results being below the limits of quantification (LOQ = 0.02 mg/L), excepting one instance where a 0.04 mg/L concentration of

  7. Biodegradation of nickel and chromium from space maintainers: an in vitro study.

    PubMed

    Bhaskar, V; Subba Reddy, V V

    2010-01-01

    Band materials are often used in the practice of pediatric dentistry. Nickel and Chromium are the main ingredients of these materials. The potential health hazards of nickel and chromium and their compounds have been the focus of attention for more than 100 years. It has established that these metals could cause hypersensitivity. The study was undertaken to analyze in vitro biodegradation of space maintainers made out of stainless steel band materials from manufacturers Dentaurum and Unitek. The leaching effect simulating the use of one, two, three, and four space maintainers in clinical practice was studied by keeping the respective number of space maintainers in the artificial saliva incubating at 37 degrees C and analyzing for nickel and chromium release after 1,7,14,21 and 28 days using atomic absorption spectrophotometer. Results showed that there was measurable release of both nickel and chromium which reached maximum level at the end of 7 days which was statistically significant (P < 0.05) and was very much below the dietary average intake even for four bands used and was not capable of causing any toxicity.

  8. Chromium boron surfaced nickel-iron base alloys

    NASA Technical Reports Server (NTRS)

    Rashid, James M. (Inventor); Friedrich, Leonard A. (Inventor); Freling, Melvin (Inventor)

    1984-01-01

    Chromium boron diffusion coatings on nickel iron alloys uniquely provide them with improvement in high cycle fatigue strength (up to 30%) and erosion resistance (up to 15 times), compared to uncoated alloy. The diffused chromium layer extends in two essential concentration zones to a total depth of about 40.times.10.sup.-6 m, while the succeeding boron layer is limited to 50-90% of the depth of the richest Cr layer nearest the surface. Both coatings are applied using conventional pack diffusion processes.

  9. The three dimensional distribution of chromium and nickel alloy welding fumes.

    PubMed

    Mori, T; Matsuda, A; Akashi, S; Ogata, M; Takeoka, K; Yoshinaka, M

    1991-08-01

    In the present study, the fumes generated from manual metal arc (MMA) and submerged metal arc (SMA) welding of low temperature service steel, and the chromium and nickel percentages in these fumes, were measured at various horizontal distances and vertical heights from the arc in order to obtain a three dimensional distribution. The MMA welding fume concentrations were significantly higher than the SMA welding fume concentrations. The highest fume concentration on the horizontal was shown in the fumes collected directly above the arc. The fume concentration vertically was highest at 50 cm height and reduced by half at 150 cm height. The fume concentration at 250 cm height was scarcely different from that at 150 cm height. The distribution of the chromium concentration vertically was analogous to the fume concentration, and a statistically significant difference in the chromium percentages was not found at the different heights. The nickel concentrations were not statistically significant within the welding processes, but the nickel percentages in the SMA welding fumes were statistically higher than in the MMA welding fumes. The highest nickel concentration on the horizontal was found in the fumes collected directly above the arc. The highest nickel concentration vertically showed in the fume samples collected at 50 cm height, but the greater the height the larger the nickel percentage in the fumes.

  10. Oxidation of TD nickel at 1050 C and 1200 C as compared with three grades of nickel of different purity

    NASA Technical Reports Server (NTRS)

    Lowell, C. E.; Grisaffe, S. J.; Deadmore, D. L.

    1972-01-01

    The isothermal oxidation of three nickels of different purity, Ni-200, Ni-270, and JM-Ni, was compared with that of TD-Ni in air at 1050 and 1200 C. The samples were oxidized as ground, as polished, or as annealed and polished. Weight change, metal loss, scale thickness, oxide morphology, and scale texture were determined. In degree of oxidation, TD-Ni was nearly the same as the higher purity materials, Ni-270 and JM-Ni; and less pure Ni-200 oxidized more than the others. However, in microstructure and scale texture the TD-Ni more closely resembled Ni-200. Grinding only charged the texture of the oxides of Ni_200 and TD-Ni.

  11. Method for heat treating iron-nickel-chromium alloy

    DOEpatents

    Not Available

    1980-04-03

    A method is described for heat treating an age-hardenable iron-nickel-chromium alloy to obtain a morphology of the gamma-double prime phase enveloping the gamma-prime, the alloy consisting essentially of about 25 to 45% nickel, 10 to 16% chromium, 1.5 to 3% of an element selected from the group consisting of molybdenum and niobium, about 2% titanium, about 3% aluminum, and the remainder substantially all iron. To obtain optimum results, the alloy is heated to a temperature of 1025 to 1075/sup 0/C for 2 to 5 minutes, cold-worked about 20 to 60%, aged at a temperature of about 775/sup 0/C for 8 hours followed by an air-cool, and then heated to a temperature in the range of 650 to 700/sup 0/C for 2 hours followed by an air-cool.

  12. Method for heat treating iron-nickel-chromium alloy

    DOEpatents

    Korenko, Michael K.

    1980-01-01

    A method for heat treating an age-hardenable iron-nickel-chromium alloy to obtain a morphology of the gamma-double prime phase enveloping the gamma-prime phase, the alloy consisting essentially of about 40 to 50% nickel, 7.5 to 14% chromium, 1.5 to 4% niobium, 0.3 to 0.75% silicon, 1 to 3% titanium, 0.1 to 0.5% aluminum, 0.02 to 1% carbon, 0.002 to 0.0015% boron and the remain substantially all iron. To obtain optimal results, the alloy is cold-worked 20 to 60% followed by heating at 1050.degree. C. for 1/2 hour with an air-cool plus heating at 800.degree. C. for 2 hours with a furnace cool to 625.degree. C. The alloy is then held at 625.degree. C. for 12 hours, followed by an air-cool.

  13. Method for heat treating iron-nickel-chromium alloy

    DOEpatents

    Merrick, Howard F.; Korenko, Michael K.

    1982-01-01

    A method for heat treating an age-hardenable iron-nickel-chromium alloy to obtain a bimodal distribution of gamma prime phase within a network of dislocations, the alloy consisting essentially of about 25% to 45% nickel, 10% to 16% chromium, 1.5% to 3% of an element selected from the group consisting of molybdenum and niobium, about 2% titanium, about 3% aluminum, and the remainder substantially all iron. To obtain optimum results, the alloy is heated to a temperature of 1025.degree. C. to 1075.degree. C. for 2-5 minutes, cold-worked about 20% to 60%, aged at a temperature of about 775.degree. C. for 8 hours followed by an air-cool, and then heated to a temperature in the range of 650.degree. C. to 700.degree. C. for 2 hours followed by an air-cool.

  14. Selective adsorption and separation of chromium (VI) on the magnetic iron-nickel oxide from waste nickel liquid.

    PubMed

    Wei, Linsen; Yang, Gang; Wang, Ren; Ma, Wei

    2009-05-30

    The selective adsorption of Cr (VI) from the wastewater of Cr (VI)-Ni (II) by magnetically iron-nickel oxide was investigated in this study. Synthetic iron-nickel oxide magnetic particles in the co-sedimentation method were used as adsorbent to remove hexavalent chromium ions. The characteristic of adsorption was evaluated by Langmuir, Freundlich isotherm and Dubinin-Kaganer-Radushkevich (DKR) equations in the simulation wastewater of Cr (VI)-Ni (II) bi-system. The energy spectra and FT-IR analysis were used to test adsorbent before and after adsorption. The obtained results suggest that the uptake of chromium (VI) effect is obvious from phosphate anions and that from others is unobvious. The maximum adsorption capacity of hexavalent chromium is about 30 mg/g at pH 5.00+/-0.02, and it was reduced by increasing the total dissolved substance (TDS) of system. Adsorption energies E are about 10.310-21.321 kJ/mol which were obtained from DKR equation in difference TDS conditions. The regeneration shows that the iron-nickel oxide has good reuse performance and the hexavalent chromium was recycled. The major adsorption mechanism proposed was the ions exchange; however the surface coordination was a main role in the condition of TDS less than 200mg/L.

  15. High temperature dissolution of chromium substituted nickel ferrite in nitrilotriacetic acid medium

    NASA Astrophysics Data System (ADS)

    Sathyaseelan, V. S.; Chandramohan, P.; Velmurugan, S.

    2016-12-01

    High temperature (HT) dissolution of chromium substituted nickel ferrite was carried out with relevance to the decontamination of nuclear reactors by way of chemical dissolution of contaminated corrosion product oxides present on stainless steel coolant circuit surfaces. Chromium substituted nickel ferrites of composition, NiFe(2-x)CrxO4 (x ≤ 1), was synthetically prepared and characterized. HT dissolution of these oxides was carried out in nitrilotriacetic acid medium at 160 °C. Dissolution was remarkably increased at 160 °C when compared to at 85 °C in a reducing decontamination formulation. Complete dissolution could be achieved for the oxides with chromium content 0 and 0.2. Increasing the chromium content brought about a marked reduction in the dissolution rate. About 40 fold decrease in rate of dissolution was observed when chromium was increased from 0 to 1. The rate of dissolution was not very significantly reduced in the presence of N2H4. Dissolution of oxide was found to be stoichiometric.

  16. Oxidation resistant, thoria-dispersed nickel-chromium-aluminum alloy

    NASA Technical Reports Server (NTRS)

    Baranow, S.; Klingler, L. J.

    1973-01-01

    Modified thoria-dispersed nickel-chromium alloy has been developed that exhibits greatly improved resistance to high-temperature oxidation. Additions of aluminum have been made to change nature of protective oxide scale entirely and to essentially inhibit oxidation at temperatures up to 1260 C.

  17. Hot corrosion resistance of nickel-chromium-aluminum alloys

    NASA Technical Reports Server (NTRS)

    Santoro, G. J.; Barret, C. A.

    1977-01-01

    The hot corrosion resistance of nickel-chromium-aluminum alloys was examined by cyclically oxidizing sodium sulfate-coated specimens in still air at 900, 1000, and 1100 C. The compositions tested were within the ternary region: Ni, Ni-50 at.% Cr, and Ni-50 at.% Al. At each temperature the corrosion data were statistically fitted to a third order regression equation as a function of chromium and aluminum contents. From these equations corrosion isopleths were prepared. Compositional regions with the best hot corrosion resistance were identified.

  18. Hot corrosion resistance of nickel-chromium-aluminum alloys

    NASA Technical Reports Server (NTRS)

    Santoro, G. J.; Barrett, C. A.

    1977-01-01

    The hot corrosion resistance of nickel-chromium-aluminum alloy was examined by cyclically oxidizing sodium sulfate coated specimens in still air at 900, 1000 and 1100 C. The compositions tested were within the ternary region: Ni; Ni-50 at.% Cr; and Ni-50 at.% Al. At each temperature the corrosion data were statistically fitted to a third order regression equation as a function of chromium and aluminum contents. Corrosion isopleths were prepared from these equations. Compositional regions with the best hot corrosion resistance were identified.

  19. Relation of Nickel Allergy with in-Stent Restenosis in Patients Treated with Cobalt Chromium Stents.

    PubMed

    Aliağaoğlu, Cihangir; Turan, Hakan; Erden, Ismail; Albayrak, Hülya; Ozhan, Hakan; Başar, Cengiz; Gürlevik, Zehra; Alçelik, Ayşegül

    2012-11-01

    In-stent restenosis (ISR) is the major limitation of percutaneous coronary stenting procedure. The elements like nickel, chromate and molybdenum are known to cause contact allergy. Hypersensitivity reaction, against these metal ions, may be one of the reasons of ISR. Cobalt chromium coronary stents, which are increasingly being used in percutaneous coronary interventions, have more nickel amount than the stainless steel stents. We aimed to investigate the association between nickel hypersensitivity reaction and ISR in patients treated with cobalt chromium coronary stents. Epicutaneous patch tests for nickel were applied to 31 patients who had undergone elective cobalt chromium coronary stent implantation and had ISR in control angiogram. Thirty patients, without ISR, were included as the control group. Patch test results and other clinical variables were compared. There was no statistically significant difference of the mean age, sex, body mass index, rate of hypercholesterolemia, diabetes, hypertension and smoking between the patients with and without ISR. All other lesion characteristics were similar in the 2 groups. According to the patch test results, 7 patients had nickel contact allergy. All of these patients were in the ISR group, which was statistically significant (p<0.006). Patients treated with cobalt chromium coronary stents and had ISR were found to have significantly more nickel allergy than the control group. Nickel allergy may play role in restenosis pathophysiology.

  20. Nickel and chromium levels in the saliva of patients with fixed orthodontic appliances.

    PubMed

    Yassaei, Soghra; Dadfarnia, Shayesta; Ahadian, Hakima; Moradi, Farshad

    2013-01-01

    The purpose of this study was to investigate the salivary concentration of nickel and chromium of patients undergoing orthodontic treatment. In this study 32 patients who presented to the orthodontic clinic were selected. The salivary samples were taken from the patients in four stages: before appliance placement and 20 days, 3 months, and 6 months following appliance placement. The salivary samples were collected in a plastic tube and were stored in the freezer before analysis. The samples were then transferred to the laboratory, and the amounts of metals were determined by graphite furnace atomic absorption spectrometry with an autosampler. Each sample was analyzed three times, and the average was reported. It was found that the average amount of nickel in the saliva 20 days after appliance placement was 0.8 μg/L more than before placement. Also, the amount of salivary nickel 20 days after the appliance placement was more than at the other stages, but the differences were not significant. The average amount of chromium in the saliva was found to be between 2.6 and 3.6 μg/L. The amount of chromium at all stages after appliance placement was more than before, but the differences between the chromium levels of saliva at all stages were not significant. There was no significant difference in the average amount of salivary nickel and chromium of patients at various stages of orthodontic appliance placement.

  1. Achieving Zero Stress in Iridium, Chromium, and Nickel Thin Films

    NASA Technical Reports Server (NTRS)

    Broadway, David M.; Weimer, Jeffrey; Gurgew, Danielle; Lis, Tomasz; Ramsey, Brian D.; O'Dell, Stephen L.; Ames, A.; Bruni, R.

    2015-01-01

    We examine a method for achieving zero intrinsic stress in thin films of iridium, chromium, and nickel deposited by magnetron sputter deposition. The examination of the stress in these materials is motivated by efforts to advance the optical performance of light-weight x-ray space telescopes into the regime of sub-arc second resolution that rely on control of the film stress to values within 10-100 MPa. A characteristic feature of the intrinsic stress behavior in chromium and nickel is their sensitivity to the magnitude and sign of the intrinsic stress with argon gas pressure, including the existence of a critical pressure that results in zero film stress. This critical pressure scales linearly with the film's density. While the effect of stress reversal with argon pressure has been previously reported by Hoffman and others for nickel and chromium, we have discovered a similar behavior for iridium. Additionally, we have identified zero stress in iridium shortly after island coalescence. This feature of film growth is used for achieving a total internal stress of -2.89 MPa for a 15.8 nm thick iridium film. The surface roughness of this low-stress film was examined using scanning probe microscopy (SPM) and x-ray reflectivity (XRR) at CuKa and these results presented and discussed.

  2. Health risk assessment of zinc, chromium, and nickel from cow meat consumption in an urban Nigerian population

    PubMed Central

    Ihedioha, Janefrances N; Okoye, Chukwuma O B; Onyechi, Uchenna A

    2014-01-01

    Background: Meat consumption is increasingly becoming a larger part of diets worldwide. However, the bioaccumulation of toxic metals from anthropogenic pollution is a potential health risk to human health. Objective: To measure the daily intake of zinc, chromium, and nickel from cow meat consumption and assess the possible health risks in an urban population in Nigeria. Methods: Dried meat samples were digested with 3 : 2HNO3 : HClO4 v/v. Zinc, chromium, and nickel concentrations were determined with atomic absorption spectrophotometer. Daily intakes of meat were obtained using a food frequency questionnaire (FFQ). Results: The estimated daily intakes (EDI) (μg/person/day) ranges were: zinc (10 496–13 459), chromium (310.90–393.73), and nickel (26.72–34.87). Estimated daily intake for zinc was 15–30% of provisional maximum tolerable daily intake (PMTDI) and for nickel it was 8–15% of tolerable daily intake (TDI). Conclusion: Chromium intakes were above recommended daily intake (RDI). Target hazard quotient (THQ) for nickel and zinc were within WHO/FAO limit. There was no evidence of possible health risk to consumers with regard to zinc and nickel. However, chromium intake should be of utmost concern, while disposal of tanning waste should be checked. PMID:25078345

  3. Isolation, identification and characterization of indigenous fungi for bioremediation of hexavalent chromium, nickel and cobalt

    NASA Astrophysics Data System (ADS)

    Hernahadini, Nelis; Suhandono, Sony; Choesin, Devi N.; Chaerun, Siti K.; Kadarusman, Ade

    2014-03-01

    Waste from nickel mining of Sorowako in South Sulawesi contains hexavalent chromium, nickel and cobalt metals in high concentration and may have a negative impact to the environment. Common waste treatment systems such as chemical treatment using a reducing reagent may still have a negative impact. Bioremediation using fungi or bacteria becomes more popular because it is an environmentally friendly alternative. The purposes of this study are to isolate and identify indigenous fungi that are resistant to heavy metals (hexavalent chromium, nickel, and cobalt) and are capable of reducing the concentration of metals in mining wastes. Ten fungal isolates were successfully isolated from the soils and pond sediments in the area of nickel mining in Sorowako. Selection of superior isolate was carried out by growing all the isolates on PDA medium, which contained all of the three metals. One superior isolate was identified to be able to grow on medium with concentrations of 6400 ppm hexavalent chromium, 200 ppm nickel and 50 ppm cobalt. Molecular identification and phylogenetic studies of the isolate using fungal PCR primers developed to amplify the ITS (internal transcribed spacer) region showed that the isolate sequence was very close to Trichoderma atroviride with 99.8% similarity. Optimum incubation time for the uptake of hexavalent chromium was 3 days, nickel and cobalt was 5 days, respectively, with an optimum pH of 4.

  4. Fretting of Nickel-Chromium-Aluminum Alloys at Temperatures to 816 C

    NASA Technical Reports Server (NTRS)

    Bill, R. C.

    1974-01-01

    A series of four nickel-based alloys containing 10 percent and 20 percent chromium in combination with 2 percent and 5 percent aluminum were fretted in dry air at temperatures to 816 C. At all temperatures, the alloys showed far less fretting wear than did high-purity nickel. This was attributed to the formation of protective oxide films on the alloys, the result of the selective oxidation of the alloy constituents. Increasing the aluminum concentration reduced fretting wear at all temperatures. Increasing the chromium concentration from 10 percent to 20 percent resulted in decreased fretting wear at 23 and 540 C, but increased fretting wear at 650 and 816 C.

  5. Toxicodynamic and toxicokinetic descriptors of combined chromium (VI) and nickel toxicity.

    PubMed

    Minigaliyeva, Ilzira A; Katsnelson, Boris A; Privalova, Larisa I; Gurvich, Vladimir B; Panov, Vladimir G; Varaksin, Anatoly N; Makeyev, Oleg H; Sutunkova, Marina P; Loginova, Nadezhda V; Kireyeva, Ekaterina P; Grigoryeva, Ekaterina V; Slyshkina, Tatyana V; Ganebnykh, Eugenia V; Grebenkina, Svetlana V

    2014-01-01

    After repeated intraperitoneal injections of nickel and chromium (VI) salts to rats, we found, and confirmed by mathematical modeling, that their combined subchronic toxicity can either be of additive type or depart from it (predominantly toward subadditivity) depending on the effect assessed. Against the background of moderate systemic toxicity, the combination under study proved to possess a marked additive genotoxicity assessed by means of the random amplification of polymorphic DNA test. We also demonstrated that chromium and nickel reciprocally influenced the retention of these metals in some organs (especially in the spleen) but not their urinary excretion in this study. © The Author(s) 2014.

  6. A Comparative Study of Biodegradation of Nickel and Chromium from Space Maintainers: An in vitro Study.

    PubMed

    Anand, Ashish; Sharma, Arun; Kumar, Piush; Sandhu, Meera; Sachdeva, Shobhit; Sachdev, Vinod

    2015-01-01

    The aim of the study was to compare and evaluate the in vitro biodegradation of nickel and chromium from space maintainers, made of three different companies, i.e (Dantaurum, Rocky mountain and Dtech) in artificial saliva. The study comprised of 30 space maintainers out of which 10 were fabricated using Dantaurum, 10 using Rocky mountain and 10 using Dtech band materials. Stainless steel wire (Dantaurum, Rocky mountain and Konark) was used for making loops and Leone solder and flux was used for soldering. Each group was further divided into four subgroups containing 1, 2, 3 and 4 space maintainers respectively. The space maintainers in each subgroup were placed in separate glass beakers containing 100 ml of artificial saliva at 37°C for 4 weeks. Salivary samples from each beaker was analyzed for nickel and chromium ions separately on days 1, 7, 14, 21 and 28 days using inductively coupled plasma-optical emission spectrophotometer. Total release of nickel and chromium from all band and loop space maintainers ranged from 0.020 to 1.524 ppm and 0.002 to 0.289 ppm respectively. The release of nickel and chromium between the groups and within the groups was not significant (p < 0.5). There was no substantial release of nickel and chromium from space maintainers made of Dantaurum, Rocky mountain and Dtech which could cause any toxicity. How to cite this article: Anand A, Sharma A, Kumar P, Sandhu M, Sachdeva S, Sachdev V. A Comparative Study of Biodegradation of Nickel and Chromium from Space Maintainers: An in vitro Study. Int J Clin Pediatr Dent 2015; 8(1):37-41.

  7. Iron-nickel-chromium alloy having improved swelling resistance and low neutron absorbence

    DOEpatents

    Korenko, Michael K.

    1986-01-01

    An iron-nickel-chromium age-hardenable alloy suitable for use in fast breeder reactor ducts and cladding which utilizes the gamma-double prime strengthening phase and characterized in having a delta or eta phase distributed at or near grain boundaries. The alloy consists essentially of about 33-39.5% nickel, 7.5-16% chromium, 1.5-4% niobium, 0.1-0.7% silicon, 0.01-0.2% zirconium, 1-3% titanium, 0.2-0.6% aluminum, and the remainder essentially all iron. Up to 0.4% manganese and up to 0.010% magnesium can be added to inhibit trace element effects.

  8. Survey of Portions of the Chromium-Cobalt-Nickel-Molybdenum Quaternary System at 1,200 Degrees C

    NASA Technical Reports Server (NTRS)

    Rideout, Sheldon Paul; Beck, Paul A

    1953-01-01

    A survey was made of portions of the chromium-cobalt-nickel-molybdenum quaternary system at 1,200 degrees c by means of microscopic and x-ray diffraction studies. Since the face-centered cubic (alpha) solid solutions form the matrix of almost all practically useful high-temperature alloys, the solid solubility limits of the quaternary alpha phase were determined up to 20 percent molybdenum. The component cobalt-nickel-molybdenum, chromium-cobalt-molybdenum, and chromium-nickel-molybdenum ternary systems were also studied. The survey of these systems was confined to the determination of the boundaries of the face-centered cubic (alpha) solid solutions and of the phases coexisting with alpha at 1,200 degrees c.

  9. Chromium modified nickel-iron aluminide useful in sulfur bearing environments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cathcart, J.V.; Liu, C.T.

    1989-06-13

    This patent describes an improved nickel-iron aluminide containing chromium and molybdenum additions to improve resistance to sulfur attack. The corrosive effects of sulfur are discussed and the chemical composition of corrosion resistant alloys is illustrated.

  10. Procedure for rapid determination of nickel, cobalt, and chromium in airborne particulate samples

    NASA Technical Reports Server (NTRS)

    Davis, W. F.; Graab, J. W.

    1972-01-01

    A rapid, selective procedure for the determination of 1 to 20 micrograms of nickel, chromium, and cobalt in airborne particulates is described. The method utilizes the combined techniques of low temperature ashing and atomic absorption spectroscopy. The airborne particulates are collected on analytical filter paper. The filter papers are ashed, and the residues are dissolved in hydrochloric acid. Nickel, chromium, and cobalt are determined directly with good precision and accuracy by means of atomic absorption. The effects of flame type, burner height, slit width, and lamp current on the atomic absorption measurements are reported.

  11. Stainless steel leaches nickel and chromium into foods during cooking.

    PubMed

    Kamerud, Kristin L; Hobbie, Kevin A; Anderson, Kim A

    2013-10-02

    Toxicological studies show that oral doses of nickel and chromium can cause cutaneous adverse reactions such as dermatitis. Additional dietary sources, such as leaching from stainless steel cookware during food preparation, are not well characterized. This study examined stainless steel grades, cooking time, repetitive cooking cycles, and multiple types of tomato sauces for their effects on nickel and chromium leaching. Trials included three types of stainless steels and a stainless steel saucepan, cooking times of 2-20 h, 10 consecutive cooking cycles, and four commercial tomato sauces. After a simulated cooking process, samples were analyzed by ICP-MS for Ni and Cr. After 6 h of cooking, Ni and Cr concentrations in tomato sauce increased up to 26- and 7-fold, respectively, depending on the grade of stainless steel. Longer cooking durations resulted in additional increases in metal leaching, where Ni concentrations increased 34-fold and Cr increased approximately 35-fold from sauces cooked without stainless steel. Cooking with new stainless steel resulted in the largest increases. Metal leaching decreases with sequential cooking cycles and stabilized after the sixth cooking cycle, although significant metal contributions to foods were still observed. The tenth cooking cycle resulted in an average of 88 μg of Ni and 86 μg of Cr leached per 126 g serving of tomato sauce. Stainless steel cookware can be an overlooked source of nickel and chromium, where the contribution is dependent on stainless steel grade, cooking time, and cookware usage.

  12. Stainless Steel Leaches Nickel and Chromium into Foods During Cooking

    PubMed Central

    Kamerud, Kristin L.; Hobbie, Kevin A.; Anderson, Kim A.

    2014-01-01

    Toxicological studies show that oral doses of nickel and chromium can cause cutaneous adverse reactions such as dermatitis. Additional dietary sources, such as leaching from stainless steel cookware during food preparation, are not well characterized. This study examined stainless steel grades, cooking time, repetitive cooking cycles, and multiple types of tomato sauces for their effects on nickel and chromium leaching. Trials included three types of stainless steels and a stainless steel saucepan; cooking times of 2 to 20 hours, ten consecutive cooking cycles, and four commercial tomato sauces. After a simulated cooking process, samples were analyzed by ICP-MS for Ni and Cr. After six hours of cooking, Ni and Cr concentrations in tomato sauce increased up to 26- and 7-fold respectively, depending on the grade of stainless steel. Longer cooking durations resulted in additional increases in metal leaching, where Ni concentrations increased 34 fold and Cr increased approximately 35 fold from sauces cooked without stainless steel. Cooking with new stainless steel resulted in the largest increases. Metal leaching decreases with sequential cooking cycles and stabilized after the sixth cooking cycle, though significant metal contributions to foods were still observed. The tenth cooking cycle, resulted in an average of 88 μg of Ni and 86 μg of Cr leached per 126 g serving of tomato sauce. Stainless steel cookware can be an overlooked source of nickel and chromium, where the contribution is dependent on stainless steel grade, cooking time, and cookware usage. PMID:23984718

  13. Application of mathematical modelling for assessing the biological half-times of chromium and nickel in field studies.

    PubMed Central

    Tossavainen, A; Nurminen, M; Mutanen, P; Tola, S

    1980-01-01

    The biological half-times of urinary chromium and nickel excretion and plasma nickel concentration were calculated for four welders and four electroplaters. A linear one-compartment kinetic model gave estimates of the half-times ranging from 15 to 41 hours for chromium in urine, from 17 to 39 hours for nickel in urine, and from 20 to 34 hours for nickel in plasma. The model allows a precise description to be made of a worker's state of exposure as affected by a varying concentration of the metals in the air. PMID:7426481

  14. Biosorption characteristics of copper (II), chromium (III), nickel (II), and lead (II) from aqueous solutions by Chara sp. and Cladophora sp.

    PubMed

    Elmaci, Ayşe; Yonar, Taner; Ozengin, Nihan

    2007-09-01

    The aim of this research was to expose individual removals of copper, chromium, nickel, and lead from aqueous solutions via biosorption using nonliving algae species, Chara sp. and Cladophora sp. Optimum pH values for biosorption of copper (II), chromium (III), nickel (II), and lead (II) from aqueous solutions were determined to be 6, 7, 7, and 3 for Cladophora sp. and 5, 3, 5, and 4 for Chara sp. respectively. Maximum adsorption capacities of Chara sp. [10.54 for chromium (III) and 61.72 for lead (II)] and Cladophora sp. [6.59 for chromium (III) and 16.75 and 23.25 for lead (II)] for chromium (III) and lead (II) are similar. On the other hand, copper (II) and nickel (II) biosorption capacity of Cladophora sp. [14.28 for copper (II) and 16.75 for nickel (II)] is greater than Chara sp. [6.506 for copper (II) and 11.76 for nickel (II)]. Significantly high correlation coefficients indicated for the Langmuir adsorption isotherm models can be used to describe the equilibrium behavior of copper, chromium, nickel, and lead adsorption onto Cladophora sp. and Chara sp.

  15. Assessment of skin exposure to nickel, chromium and cobalt by acid wipe sampling and ICP-MS.

    PubMed

    Lidén, Carola; Skare, Lizbet; Lind, Birger; Nise, Gun; Vahter, Marie

    2006-05-01

    There is a great need to accurately assess skin exposure to contact allergens. We have developed a technique for assessment of skin exposure to nickel, chromium and cobalt using acid wipe sampling by cellulose wipes with 1% nitric acid. Chemical analysis was performed by inductively coupled plasma mass spectrometry (ICP-MS). The recovery of nickel, chromium and cobalt from arms and palms was 93%. The analytical result is expressed in terms of mass per unit area (microg/cm(2)). The developed acid wipe sampling technique is suitable for determination of nickel, chromium and cobalt deposited on the skin. The technique may be used in workplace studies, in studies of individuals in the general population, in dermatitis patients, in identification of risk groups, as well as in developing preventive strategies and in follow-up after intervention.

  16. Evaluation of Nickel and Chromium Ion Release During Fixed Orthodontic Treatment Using Inductively Coupled Plasma-Mass Spectrometer: An In Vivo Study

    PubMed Central

    Nayak, Rabindra S; Khanna, Bharti; Pasha, Azam; Vinay, K; Narayan, Anjali; Chaitra, K

    2015-01-01

    Background: Fixed orthodontic appliances with the use of stainless steel brackets and archwires made of nitinol have a corrosive potential in the oral environment. Nickel and chromium ions released from these appliances act as allergens apart from being cytotoxic, mutagenic and carcinogenic in smaller quantities in the range of nanograms. This study was done to evaluate the release of nickel and chromium ions from orthodontic appliances in the oral cavity using Inductively Coupled Plasma-Mass Spectrometer (ICP-MS). Materials and Methods: Saliva samples from 30 orthodontic patients undergoing treatment with 0.022″ MBT mechanotherapy were collected prior to commencement of treatment, after initial aligning wires and after 10-12 months of treatment. Salivary nickel and chromium ion concentration was measured in parts per billion (ppb) using ICP-MS. Results: Mean, standard deviation and range were computed for the concentrations of ions obtained. Results analyzed using ANOVA indicated a statistically significant increase of 10.35 ppb in nickel ion concentration and 33.53 ppb in chromium ion concentration after initial alignment. The ionic concentration at the end of 10-12 months of treatment showed a statistically significant increase in of 17.92 ppb for chromium and a statistically insignificant decrease in nickel ion concentration by 1.58 ppb. Pearson’s correlation coefficient showed a positive correlation for an increase in nickel concentration after aligning, but not at the end of 10-12 months. A positive correlation was seen for an increase in chromium ion concentration at both time intervals. Conclusion: Nickel and chromium ion concentration in saliva even though below the recommended daily allowance should not be ignored in light of the new knowledge regarding effects of these ions at the molecular level and the allergic potential. Careful and detailed medical history of allergy is essential. Nickel free alternatives should form an essential part of an

  17. Evaluation of Nickel and Chromium Ion Release During Fixed Orthodontic Treatment Using Inductively Coupled Plasma-Mass Spectrometer: An In Vivo Study.

    PubMed

    Nayak, Rabindra S; Khanna, Bharti; Pasha, Azam; Vinay, K; Narayan, Anjali; Chaitra, K

    2015-08-01

    Fixed orthodontic appliances with the use of stainless steel brackets and archwires made of nitinol have a corrosive potential in the oral environment. Nickel and chromium ions released from these appliances act as allergens apart from being cytotoxic, mutagenic and carcinogenic in smaller quantities in the range of nanograms. This study was done to evaluate the release of nickel and chromium ions from orthodontic appliances in the oral cavity using Inductively Coupled Plasma-Mass Spectrometer (ICP-MS). Saliva samples from 30 orthodontic patients undergoing treatment with 0.022″ MBT mechanotherapy were collected prior to commencement of treatment, after initial aligning wires and after 10-12 months of treatment. Salivary nickel and chromium ion concentration was measured in parts per billion (ppb) using ICP-MS. Mean, standard deviation and range were computed for the concentrations of ions obtained. Results analyzed using ANOVA indicated a statistically significant increase of 10.35 ppb in nickel ion concentration and 33.53 ppb in chromium ion concentration after initial alignment. The ionic concentration at the end of 10-12 months of treatment showed a statistically significant increase in of 17.92 ppb for chromium and a statistically insignificant decrease in nickel ion concentration by 1.58 ppb. Pearson's correlation coefficient showed a positive correlation for an increase in nickel concentration after aligning, but not at the end of 10-12 months. A positive correlation was seen for an increase in chromium ion concentration at both time intervals. Nickel and chromium ion concentration in saliva even though below the recommended daily allowance should not be ignored in light of the new knowledge regarding effects of these ions at the molecular level and the allergic potential. Careful and detailed medical history of allergy is essential. Nickel free alternatives should form an essential part of an orthodontist's inventory.

  18. Methods to Develop Inhalation Cancer Risk Estimates for Chromium and Nickel Compounds

    EPA Science Inventory

    This document summarizes the approaches and rationale for the technical and scientific considerations used to derive inhalation cancer risks for emissions of chromium and nickel compounds from electric utility steam generating units.

  19. PARTITIONING OF THE REFRACTORY METALS, NICKEL AND CHROMIUM, IN COMBUSTION SYSTEMS

    EPA Science Inventory

    The partitioning of nickel (Ni) and Chromium (Cr) in combustion systems was investigated theoretically and experimentally. In comparison to other volatile and semi-volatile metals, both Ni and Cr are usually considered to be refractory (non-volatile). Theoretical predictions ba...

  20. Skin deposition of nickel, cobalt, and chromium in production of gas turbines and space propulsion components.

    PubMed

    Julander, Anneli; Skare, Lizbet; Mulder, Marie; Grandér, Margaretha; Vahter, Marie; Lidén, Carola

    2010-04-01

    Skin exposure to nickel, cobalt, and chromium may cause sensitization and allergic contact dermatitis and it is known that many alloys and platings may release significant amounts of the metals upon contact with skin. Occupational exposure to these sensitizing metals has been studied in different settings with regards to airborne dust and different biological end points, but little is known about deposition on skin from airborne dust and direct contact with materials containing the metals. In this study, skin deposition was studied in 24 workers in an industry for development and manufacturing of gas turbines and space propulsion components. The workers were employed in three departments, representing different exposure scenarios: tools sharpening of hard metal items, production of space propulsion structures, and thermal application of different metal-containing powders. A novel acid wipe sampling technique was used to sample metals from specific skin surfaces on the hands and the forehead of the workers. Total amounts of nickel, cobalt, and chromium were measured by inductively coupled plasma mass spectrometry. The result showed that nickel, cobalt, and chromium could be detected on all skin surfaces sampled. The highest level of nickel was 15 microg cm(-2) h(-1), the highest for cobalt was 4.5 microg cm(-2) h(-1), and for chromium 0.6 microg cm(-2) h(-1). The three departments had different exposures regarding the metals. The highest levels of nickel on the skin of the workers were found in the thermal applications department, cobalt in the tools sharpening department, and chromium in the space propulsion components department. In conclusion, the workers' exposure to the metals was more likely to come from direct skin contact with items, rather than from airborne dust, based on the fact that the levels of metals were much higher on the fingers than on the back side of the hands and the forehead. The skin exposure levels of nickel and cobalt detected are judged

  1. Chromium modified nickel-iron aluminide useful in sulfur bearing environments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cathcart, J.V.; Liu, C.T.

    1989-06-13

    This patent describes a composition of matter consisting essentially of 18 to 19 at. % aluminum, 10 to 11.5 at. % iron, 6.5 to 8.0 at. % chromium, 0.4 to 0.8 at. % molybdenum, 0.1 to 0.3 at. % zirconium, 0.05 to 0.2 at. % boron and the balance nickel.

  2. An Accurate Methodology to detect Leaching of Nickel and Chromium Ions in the Initial Phase of Orthodontic Treatment: An in vivo Study.

    PubMed

    Kumar, R Vinoth; Rajvikram, N; Rajakumar, P; Saravanan, R; Deepak, V Arun; Vijaykumar, V

    2016-03-01

    The aim of this study was to evaluate the release of nickel and chromium ions in human saliva during fixed orthodontic therapy. Ten patients with Angle's Class-I malocclusion with bimaxillary protrusion without any metal restorations or crowns and with all the permanent teeth were selected. Five male patients and five female patients in the age group range of 14 to 23 years were scheduled for orthodontic treatment with first premolar extraction. Saliva samples were collected in three stages: sample 1, before orthodontic treatment; sample 2, after 10 days of bonding sample; and sample 3, after 1 month of bonding. The samples were analyzed for the following metals nickel and chromium using inductively coupled plasma optical emission spectrometry (ICP-OES). The levels of nickel and chromium were statistically significant, while nickel showed a gradual increase in the first 10 days and a decline thereafter. Chromium showed a gradual increase and was statistically significant on the 30th day. There was greatest release of ions during the first 10 days and a gradual decline thereafter. Control group had traces of nickel and chromium. While comparing levels of nickel in saliva, there was a significant rise from baseline to 10th and 30th-day sample, which was statistically significant. While comparing 10th day to that of 30th day, there was no statistical significance. The levels of chromium ion in the saliva were more in 30th day, and when comparing 10th-day sample with 30th day, there was statistical significance. Nickel and chromium levels were well within the permissible levels. However, some hypersensitive individuals may be allergic to this minimal permissible level.

  3. [The effect of epigallocatechin gallate (EGCG) on the surface properties of nickel-chromium dental casting alloys after electrochemical corrosion].

    PubMed

    Qiao, Guang-yan; Zhang, Li-xia; Wang, Jue; Shen, Qing-ping; Su, Jian-sheng

    2014-08-01

    To investigate the effect of epigallocatechin gallate (EGCG) on the surface properties of nickel-chromium dental alloys after electrochemical corrosion. The surface morphology and surface structure of nickel-chromium dental alloys were examined by stereomicroscope and scanning electron microscopy before and after electrochemical tests in 0 g/L and 1.0 g/L EGCG artificial saliva. The surface element component and chemical states of nickel-chromium dental alloys were analyzed by X-ray photoelectron spectrograph after electrochemical tests in 0 g/L and 1.0 g/L EGCG artificial saliva. More serious corrosion happened on the surface of nickel-chromium alloy in 1.0 g/L EGCG artificial saliva than in 0 g/L EGCG. The diameters of corrosion pits were smaller, and the dendrite structure of the alloy surface was not affected in 0 g/L EGCG. While the diameters of corrosion pits were larger, the dendritic interval of the alloy surface began to merge, and the dendrite structure was fuzzy in 1.0 g/L EGCG. In addition, the O, Ni, Cr, Be, C and Mo elements were detected on the surface of nickel-chromium alloys after sputtered for 120 s in 0 g/L EGCG and 1.0 g/L EGCG artificial saliva after electrochemical corrosion, and the surface oxides were mainly NiO and Cr(2)O(3). Compared with 0 g/L EGCG artificial saliva, the content of O, NiO and Cr(2)O(3) were lower in 1.0 g/L EGCG. The results of surface morphology and the corrosion products both show that the corrosion resistance of nickel-chromium alloys become worse and the oxide content of corrosion products on the surface reduce in 1.0 g/L EGCG artificial saliva.

  4. Hot hardness of nickel-rich nickel-chromium-aluminum alloys

    NASA Technical Reports Server (NTRS)

    Levine, S. R.

    1976-01-01

    Rockwell A hardness of cast nickel-chromium-aluminum (NiCrAl) alloys was examined from ambient to 1150 K and compared to cast NiAl and IN-100. Alloy constitution was either gamma, gamma prime + gamma or gamma + beta + alpha + gamma prime. Below 1000 K beta containing NiCrAl alloys have hardnesses comparable to IN-100; above 1000 K they soften faster than IN-100. At 1150 K the hardness of beta-containing NiCrAl alloys decreases with increasing beta-content. The beta-containing NiCrAl alloys were harder than beta-NiAl. The ultimate tensile strengths of the NiCrAl alloys were estimated. The effects of NiCrAl coatings on strength and fatigue life of cooled turbine components were deduced.

  5. Estimation of Release of Nickel and Chromium by Indian Made Orthodontic Appliance in Saliva

    PubMed Central

    Parashar, Sandeep; Gupta, Ankur; Hegde, Chatura; Anand, Neelima

    2015-01-01

    Introduction With increasing use of Indian made orthodontic materials, need was felt to know nickel and chromium release from these material. Materials and Methods This study was conducted on simulated appliances consisting of brackets (022″Roth, Modern orthodontics, Ludhiana, India), from second premolar to central incisor, buccal tube and 0.019×0.025- inch SS arch wires secured with SS ligatures. Immersion was done in artificial saliva. Samples were analysed to using Atomic Absorption Photospectrometer (GVC ScientificEquipment Pvt. Ltd Australia) at AES Laboratories (P) Ltd., Noida India on 1st, 7th, 14th and 28th day. Results SPSS (ver 17, Inc., Chicago, Illinois, USA) was used toperform the statistical analysis. Descriptive statistics i.e. median and 25 and75 percentiles were used. Peak nickel release was on 7th day and subsequently declined over 14th and 28th day. The peak level of chromium concentration was on 14th day, which declined thereafter. Conclusion Average daily release of nickel and chromium over a period of one month was 97.368 μg/day and 47.664 μg/day respectively. The estimated release rates were approximately 32% and 16% of the reported average daily dietary. PMID:26501018

  6. Release of nickel and chromium in common foods during cooking in 18/10 (grade 316) stainless steel pots.

    PubMed

    Guarneri, Fabrizio; Costa, Chiara; Cannavò, Serafinella P; Catania, Stefania; Bua, Giuseppe D; Fenga, Concettina; Dugo, Giacomo

    2017-01-01

    Literature data on the release of nickel and chromium from stainless steel cookware during food preparation are contrasting, have often been obtained with uncommon foods and/or procedures, and are thus not widely applicable. To assess the release of nickel and chromium from 18/10 (grade 316) stainless steel pots in cooking conditions that are common in an urban lifestyle. Tomato sauce and lemon marmalade were cooked for 1 h, alone or with added EDTA, in used or unused stainless steel pots from different manufacturers. Additionally, aqueous solutions at pH 2.3, 7.7 and 9 were boiled for 1 h in the same pots. Metal release was assessed with inductively coupled plasma mass spectrometry. The release of nickel and chromium increased with cooking/boiling time, was higher with unused pots, at low pH or with EDTA, and was sometimes remarkably different between manufacturers. In all experiments, the amounts released were below known allergy-triggering thresholds. Under common conditions, the use of 18/10 stainless steel pots is considered to be safe for the majority of nickel-allergic and/or chromium-allergic subjects. However, the total amount of nickel contained in foods and released from pots may exceed the individual threshold for triggering allergy, potentially causing problems for highly sensitive patients, or, conversely, contribute to induction of immunotolerance by oral low-dose exposure. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Exposure to Nickel, Chromium, or Cadmium Causes Distinct Changes in the Gene Expression Patterns of a Rat Liver Derived Cell Line

    PubMed Central

    Permenter, Matthew G.; Lewis, John A.; Jackson, David A.

    2011-01-01

    Many heavy metals, including nickel (Ni), cadmium (Cd), and chromium (Cr) are toxic industrial chemicals with an exposure risk in both occupational and environmental settings that may cause harmful outcomes. While these substances are known to produce adverse health effects leading to disease or health problems, the detailed mechanisms remain unclear. To elucidate the processes involved in the toxicity of nickel, cadmium, and chromium at the molecular level and to perform a comparative analysis, H4-II-E-C3 rat liver-derived cell lines were treated with soluble salts of each metal using concentrations derived from viability assays, and gene expression patterns were determined with DNA microarrays. We identified both common and unique biological responses to exposure to the three metals. Nickel, cadmium, chromium all induced oxidative stress with both similar and unique genes and pathways responding to this stress. Although all three metals are known to be genotoxic, evidence for DNA damage in our study only exists in response to chromium. Nickel induced a hypoxic response as well as inducing genes involved in chromatin structure, perhaps by replacing iron in key proteins. Cadmium distinctly perturbed genes related to endoplasmic reticulum stress and invoked the unfolded protein response leading to apoptosis. With these studies, we have completed the first gene expression comparative analysis of nickel, cadmium, and chromium in H4-II-E-C3 cells. PMID:22110744

  8. Comparison of nickel and chromium ions released from stainless steel and NiTi wires after immersion in Oral B®, Orthokin® and artificial saliva.

    PubMed

    Jamilian, Abdolreza; Moghaddas, Omid; Toopchi, Shabnam; Perillo, Letizia

    2014-07-01

    Oral environment of the mouth is a suitable place for biodegradation of alloys used in orthodontic wires. The toxicity of these alloys namely nickel and chromium has concerned the researchers about the release of these ions from orthodontic wires and brackets. The aim of this study was to measure the levels of nickel and chromium ions released from 0.018" stainless steel (SS) and NiTi wires after immersion in three solutions. One hundred and forty-four round NiTi and 144 round SS archwires with the diameters of 0.018" were immersed in Oral B®, Orthokin® and artificial saliva. The amounts of nickel and chromium ions released were measured after 1, 6, 24 hours and 7 days. Two way repeated ANOVA showed that the amount of chromium and nickel significantly increased in all solutions during all time intervals (p < 0.002). Chromium and nickel ions were released more in NiTi wire in all solutions compared with SS wire. The lowest increase rate was also seen in artificial saliva. There is general consensus in literature that even very little amounts of nickel and chromium are dangerous for human body specially when absorbed orally; therefore, knowing the precise amount of these ions released from different wires when immersed in different mouthwashes is of high priority.

  9. Release of nickel and chromium ions from orthodontic wires following the use of teeth whitening mouthwashes.

    PubMed

    Mirhashemi, AmirHossein; Jahangiri, Sahar; Kharrazifard, MohammadJavad

    2018-02-05

    Corrosion resistance is an important requirement for orthodontic appliances. Nickel and chromium may be released from orthodontic wires and can cause allergic reactions and cytotoxicity when patients use various mouthwashes to whiten their teeth. Our study aimed to assess the release of nickel and chromium ions from nickel titanium (NiTi) and stainless steel (SS) orthodontic wires following the use of four common mouthwashes available on the market. This in vitro, experimental study was conducted on 120 orthodontic appliances for one maxillary quadrant including five brackets, one band and half of the required length of SS, and NiTi wires. The samples were immersed in Oral B, Oral B 3D White Luxe, Listerine, and Listerine Advance White for 1, 6, 24, and 168 h. The samples immersed in distilled water served as the control group. Atomic absorption spectroscopy served to quantify the amount of released ions. Nickel ions were released from both wires at all time-points; the highest amount was in Listerine and the lowest in Oral B mouthwashes. The remaining two solutions were in-between this range. The process of release of chromium from the SS wire was the same as that of nickel. However, the release trend in NiTi wires was not uniform. Listerine caused the highest release of ions. Listerine Advance White, Oral B 3D White Luxe, and distilled water were the same in terms of ion release. Oral B showed the lowest amount of ion release.

  10. An in vitro comparison of nickel and chromium release from brackets.

    PubMed

    Haddad, Ana Cristina Soares Santos; Tortamano, Andre; Souza, Alexandre Luís de; Oliveira, Pedro Vitoriano de

    2009-01-01

    This study aimed at comparing amounts of nickel (Ni) and chromium (Cr) released from brackets from different manufacturers in simulated oral environments. 280 brackets were equally divided into 7 groups according to manufacturer. 6 groups of brackets were stainless steel, and 1 group of brackets was made of a cobalt-chromium alloy with low Ni content (0.5%). International standard ISO 10271/2001 was applied to provide test methods. Each bracket was immersed in 0.5 ml of synthetic saliva (SS) or artificial plaque fluid (PF) over a period of 28 days at 37 degrees Celsius. Solutions were replaced every 7 days, and were analyzed by spectrometry. The Kruskal-Wallis test was applied. Amounts of Ni release in SS (microg L(-1) per week) varied between groups from 'bellow detection limits' to 694, and from 49 to 5,948.5 in PF. The group of brackets made of cobalt-chromium alloy, with the least nickel content, did not release the least amounts of Ni. Amounts of Cr detected in SS and in PF (microg L(-1) per week) were from 1 to 10.4 and from 50.5 to 8,225, respectively. It was therefore concluded that brackets from different manufacturers present different corrosion behavior. Further studies are necessary to determine clinical implications of the findings.

  11. Chromium, nickel and vanadium mobility in soils derived from fluvioglacial sands.

    PubMed

    Agnieszka, Jeske; Barbara, Gworek

    2012-10-30

    The presented study was focused on soils developed from fluvioglacial sands from the Puszcza Borecka forest complex. The mobility of chromium, nickel and vanadium was evaluated with regard to litho- and pedogenic factors. The aim of the study was to determine with which soil constituents fractions of heavy metals are bound with particular attention drawn on the mobile fractions (F1+F2). Heavy metal fractions in the soils were determined using the sequential extraction method of Tessier et al. The purpose of sequential extraction methods to soil samples provides relevant information about possible toxicity when they are discharged into the soil environment. Chromium, nickel, and vanadium occurred predominantly in the fraction bound with iron and manganese oxides and in the residual fraction, thus showed low mobility. With regard to mobility, the elements studied can be arranged as follows: V

  12. Effects of long-term fixed orthodontic treatment on salivary nickel and chromium levels: a 1-year prospective cohort study.

    PubMed

    Amini, Fariborz; Rakhshan, Vahid; Mesgarzadeh, Nasim

    2012-12-01

    Effect of long-term orthodontic treatment on salivary nickel and chromium has not been quite assessed except in few retrospective studies with controversial results. The aim of this prospective study was to measure salivary levels of these ions during 1 year of orthodontic treatment. Saliva samples were collected from 20 orthodontic patients, before treatment (control) and 6 and 12 months later. Nickel and chromium concentrations were determined using atomic absorption spectrophotometry. Data were analyzed using one- and two-way repeated-measures ANOVA, Bonferroni, Friedman (α = 0.05), and Wilcoxon signed-ranks tests (α = 0.016). Average nickel level changed from 9.75 ± 5.02 to 10.37 ± 6.94 and then to 8.32 ± 4.36 μg/L in 1 year. Average chromium concentration changed from 3.86 ± 1.34 to 4.6 ± 6.11 and then to 2.04 ± 1.66 μg/L. Alterations in nickel values were not statistically significant [P = 0.468 (ANOVA)], but fluctuations in chromium levels were [P = 0.021 (Friedman)]. The decrease in chromium concentration after 12 months was significant compared to the control [P = 0.004 (Wilcoxon)]. Although slightly increased after 6 months, the concentration of both ions dropped to levels slightly lower than the control groups after 12 months.

  13. Nickel and chromium isotopes in Allende inclusions

    NASA Technical Reports Server (NTRS)

    Birck, J. L.; Lugmair, G. W.

    1988-01-01

    High-precision nickel and chromium isotopic measurements were carried out on nine Allende inclusions. It is found that Ni-62, Ni-64, excesses are present in at least three of the samples. The results suggest that the most likely mechanism for the anomalies is a neutron-rich statistical equilibrium process. An indication of elevated Ni-60 is found in almost every inclusion measured. This effect is thought to be related to the decay of now extinct Fe-60. An upper limit of 1.6 X 10 to the -6th is calculated for the Fe-60/Fe-56 ratio at the time these Allende inclusions crystallized.

  14. Nickel and chromium ion release from stainless steel bracket on immersion various types of mouthwashes

    NASA Astrophysics Data System (ADS)

    Mihardjanti, M.; Ismah, N.; Purwanegara, M. K.

    2017-08-01

    The stainless steel bracket is widely used in orthodontics because of its mechanical properties, strength, and good biocompatibility. However, under certain conditions, it can be susceptible to corrosion. Studies have reported that the release of nickel and chromium ions because of corrosion can cause allergic reactions in some individuals and are mutagenic. The condition of the oral environment can lead to corrosion, and one factor that can alter the oral environment is mouthwash. The aim of this study was to measure the nickel and chromium ions released from stainless steel brackets when immersed in mouthwash and aquadest. The objects consisted of four groups of 17 maxillary premolar brackets with .022 slots. Each group was immersed in a different mouthwash and aquadest and incubated at 37 °C for 30 days. After 30 days of immersion, the released ions were measured using the ICP-MS (Inductively Coupled Plasma-Mass Spectrometer). For statistical analysis, both the Kruskal-Wallis and Mann-Whitney tests were used. The results showed differences among the four groups in the nickel ions released (p < 0.05) and the chromium ions released (p < 0.5). In conclusion, the ions released as a result of mouthwash immersion have a small value that is below the limit of daily intake recommended by the World Health Organization.

  15. Development of an inhalation system of high melting point metal fumes and its use for exposure of rats to chromium and nickel fumes.

    PubMed

    Serita, F; Homma, K; Fukuda, K; Sawatari, K; Suzuki, Y; Toya, T

    1990-01-01

    An experimental inhalation system was developed for fumes generated from powders of high melting point metals such as chromium, nickel, manganese and iron. The system consisted of a plasma flame metal sprayer as a fume generator, a granular bed type fume collector, a fluidized bed aerosol generator, an exposure and a control chamber of a horizontal-flow type and inhalant monitoring and controlling units. Performance of the chambers was ensured by a distribution test using flyash as a test aerosol. Using this system, rats were exposed to chromium fumes for one week or to nickel fumes for two months. The exposure concentrations of the chromium and nickel fumes were 1.85 +/- 0.55 mg/m3 and 0.51 +/- 0.15 mg/m3 (mean +/- SD), near the target levels of 2 mg/m3 and 0.5 mg/m3, respectively. The mass median aerodynamic diameter and the geometric standard deviation of the chromium fumes were 2.1 microns and 2.00, respectively. Those of the nickel fumes were 3.7 microns and 1.74, respectively. Species analysis of these fume particles revealed that 26.4% of the total chromium was hexavalent and the residue was trivalent and that 1-3% of the total nickel was nickel(III) and the residue was nickel(II). Inhaled-metal concentrations in the lungs showed steady increases with the exposure periods and were within the normal range of variation. On the basis of these results, it is concluded that this system is useful for long-term inhalation experiments using high melting point metal fumes.

  16. EMISSIONS OF METALS, CHROMIUM AND NICKEL SPECIES, AND ORGANICS FROM MUNICIPAL WASTEWATER SLUDGE INCINERATORS

    EPA Science Inventory

    In order to provide data to support regulations on municipal wastewater sludge incineration, emissions of metals, hexavalent chromium, nickel subsulfide, polychlorinated dibenzo-dioxins and furans (PCDD/PCDFs), semivolatile and volatile organic compounds, carbon monoxide (CO)...

  17. Release of nickel and chromium ions in the saliva of patients with fixed orthodontic appliance: An in-vivo study.

    PubMed

    Dwivedi, Anoop; Tikku, Tripti; Khanna, Rohit; Maurya, Rana Pratap; Verma, Geeta; Murthy, R C

    2015-01-01

    Various components of fixed orthodontic appliances are continuously interacting with saliva and other fluids in the mouth releasing various metal ions including nickel and chromium that can cause damaging effects if their concentration exceeds above the toxic dose. To determine and compare the level of nickel and chromium in the saliva of patients undergoing fixed orthodontic treatment at different time periods. The sample of saliva of 13 patients was taken at different time periods that is: Group 1 (before appliance placement), Group II, III, and IV (after 1-week, 1-month, and 3 months of appliance placement respectively). The fixed appliance comprised of brackets, bands, buccal tubes, lingual sheath, transpalatal arch and wires composed of Ni-Ti and stainless steel. The level of ions was determined using graphite furnace atomic absorption spectro-photometry. The data thus obtained were statistically analyzed using SPSS Statistical Analysis Software (Version 15.0). Level of nickel and chromium in saliva was highest in Group II and lowest in Groups I for both the ions. On comparison among different Groups, it was statistically significant for all the groups (<0.001) except between Group III and Group IV. The release of nickel and chromium was maximum at 1-week and then the level gradually declined. These values were well below the toxic dose of these ions. The results should be viewed with caution in subjects with Ni hypersensitivity.

  18. Simultaneous material flow analysis of nickel, chromium, and molybdenum used in alloy steel by means of input-output analysis.

    PubMed

    Nakajima, Kenichi; Ohno, Hajime; Kondo, Yasushi; Matsubae, Kazuyo; Takeda, Osamu; Miki, Takahiro; Nakamura, Shinichiro; Nagasaka, Tetsuya

    2013-05-07

    Steel is not elemental iron but rather a group of iron-based alloys containing many elements, especially chromium, nickel, and molybdenum. Steel recycling is expected to promote efficient resource use. However, open-loop recycling of steel could result in quality loss of nickel and molybdenum and/or material loss of chromium. Knowledge about alloying element substance flow is needed to avoid such losses. Material flow analyses (MFAs) indicate the importance of steel recycling to recovery of alloying elements. Flows of nickel, chromium, and molybdenum are interconnected, but MFAs have paid little attention to the interconnected flow of materials/substances in supply chains. This study combined a waste input-output material flow model and physical unit input-output analysis to perform a simultaneous MFA for nickel, chromium, and molybdenum in the Japanese economy in 2000. Results indicated the importance of recovery of these elements in recycling policies for end-of-life (EoL) vehicles and constructions. Improvement in EoL sorting technologies and implementation of designs for recycling/disassembly at the manufacturing phase are needed. Possible solutions include development of sorting processes for steel scrap and introduction of easier methods for identifying the composition of secondary resources. Recovery of steel scrap with a high alloy content will reduce primary inputs of alloying elements and contribute to more efficient resource use.

  19. Reaction diffusion in the nickel-chromium-aluminum and cobalt-chromium-aluminum systems

    NASA Technical Reports Server (NTRS)

    Levine, S. R.

    1977-01-01

    The effects of MCrAl coating-substrate interdiffusion on oxidation life and the general mutliphase, multicomponent diffusion problem were examined. Semi-infinite diffusion couples that had sources representing coatings and sinks representing gas turbine alloys were annealed at 1,000, 1,095, 1,150, or 1,205 C for as long as 500 hours. The source and sink aluminum and chromium contents and the base metal (cobalt or nickel) determined the parabolic diffusion rate constants of the couples and predicted finite coating lives. The beta source strength concept provided a method (1) for correlating beta recession rate constants with composition; (2) for determining reliable average total, diffusion, and constitutional activation energies; and (3) for calculating interdiffusion coefficients.

  20. Human biomonitoring of chromium and nickel from an experimental exposure to manual metal arc welding fumes of low and high alloyed steel.

    PubMed

    Bertram, Jens; Brand, Peter; Schettgen, Thomas; Lenz, Klaus; Purrio, Ellwyn; Reisgen, Uwe; Kraus, Thomas

    2015-05-01

    The uptake and elimination of metals from welding fumes is currently not fully understood. In the Aachen Workplace Simulation Laboratory (AWSL) it is possible to investigate the impact of welding fumes on human subjects under controlled exposure conditions. In this study, the uptake and elimination of chromium or chromium (VI) respectively as well as nickel was studied in subjects after exposure to the emissions of a manual metal arc welding process using low or high alloyed steel. In this present study 12 healthy male non-smokers, who never worked as welders before, were exposed for 6h to welding fumes of a manual metal arc welding process. In a three-fold crossover study design, subjects were exposed in randomized order to either clean air, emissions from welding low alloyed steel, and emissions from welding high alloyed steel. Particle mass concentration of the exposure aerosol was 2.5mg m(-3). The content of chromium and nickel in the air was determined by analysing air filter samples on a high emission scenario. Urine analysis for chromium and nickel was performed before and after exposure using methods of human biomonitoring. There were significantly elevated chromium levels after exposure to welding fumes from high alloyed steel compared to urinary chromium levels before exposure to high alloyed welding fumes, as well as compared to the other exposure scenarios. The mean values increased from 0.27 µg l(-1) to 18.62 µg l(-1). The results were in good agreement with already existing correlations between external and internal exposure (German exposure equivalent for carcinogenic working materials EKA). The variability of urinary chromium levels was high. For urinary nickel no significant changes could be detected at all. Six-hour exposure to 2.5mg m(-3) high alloyed manual metal arc welding fumes lead to elevated urinary chromium levels far higher (7.11-34.16 µg l(-1)) than the German biological exposure reference value (BAR) of 0.6 µg l(-1) directly after

  1. Effect of nickel and chromium on gingival tissues during orthodontic treatment: a longitudinal study.

    PubMed

    Ramadan, Ahmed Abdel-Fattah

    2004-01-01

    To determine the influence of chromium and nickel concentrations in saliva and their effects on gingival tissues during orthodontic treatment. Twenty orthodontic patients (10 males and 10 females), 17 to 20 years of age, were treated with fixed orthodontic appliances in the maxillary arch. Using atomic absorption spectrophotometer, the concentration of both metals was recorded during pretreatment, at 3 and 12 months into treatment, and 1 month after debonding. The depth of gingival crevice was recorded as well. After 3 months, 20% of females and 10% of males in this study showed allergic reaction in a form of gingivitis. This had disappeared by 1 month after appliance removal. While allergy to either nickel or chromium is not a serious medical problem, oral hygiene measures in at-risk patients should be optimal, with use of fluoride-free toothpaste and mouthrinse.

  2. Precipitation hardenable iron-nickel-chromium alloy having good swelling resistance and low neutron absorbence

    DOEpatents

    Korenko, Michael K.; Merrick, Howard F.; Gibson, Robert C.

    1980-01-01

    An iron-nickel-chromium age-hardenable alloy suitable for use in fast breeder reactor ducts and cladding which utilizes the gamma-double prime strengthening phase and characterized in having a morphology of the gamma-double prime phase enveloping the gamma-prime phase and delta phase distributed at or near the grain boundaries. The alloy consists essentially of about 40-50% nickel, 7.5-14% chromium, 1.5-4% niobium, 0.25-0.75% silicon, 1-3% titanium, 0.1-0.5% aluminum, 0.02-0.1% carbon, 0.002-0.015% boron, and the balance iron. Up to 2% manganese and up to 0.01% magnesium may be added to inhibit trace element effects; up to 0.1% zirconium may be added to increase radiation swelling resistance; and up to 3% molybdenum may be added to increase strength.

  3. Retention strength of cobalt-chromium vs nickel-chromium titanium vs CP titanium in a cast framework association of removable partial overdenture.

    PubMed

    Souza, Jose Everaldo de Aquino; Silva, Nelson Renato Franca Alves da; Coelho, Paulo Guilherme; Zavanelli, Adriana Cristina; Ferracioli, Renata Cristina Silveira Rodrigues; Zavanelli, Ricardo Alexandre

    2011-05-01

    There is little information considering the framework association between cast clasps and attachments. The aim of this study was to evaluate the retention strength of frameworks match circumferential clasps and extra resilient attachment cast in three different alloys (cobalt-chromium, nickel-chromium titanium and commercially pure titanium), using two undercut (0.25 and 0.75 mm) and considering different period of time (0, 1/2, 1, 2, 3, 4 and 5 years). Using two metallic matrices, representing a partially edentulous mandibular right hemiarch with the first molar crown, canine root and without premolars, 60 frameworks were fabricated. Three groups (n = 20) of each metal were cast and each group was divided into two subgroups (n = 10), corresponding the molar undercut of 0.25 mm and 0.75 mm. The nylon male was positioned at the matrix and attached to the acrylic resin of the prosthetic base. The samples were subjected to an insertion and removal test under artificial saliva environment. The data were analyzed and compared with ANOVAs and Tukey's test at 95% of probability. The groups cast in cobaltchromium and nickel-chromium-titanium had the highest mean retention strength (5.58 N and 6.36 N respectively) without significant difference between them, but statistically different from the group cast in commercially pure titanium, which had the lowest mean retention strength in all the periods (3.46 N). The association frameworks using nickel-chromium- titanium and cobalt-chromium could be used with 0.25 mm and 0.75 mm of undercut, but the titanium samples seems to decrease the retention strength, mainly in the 0.75 mm undercut. The circumferential clasps cast in commercially pure titanium used in 0.75 mm undercuts have a potential risk of fractures, especially after the 2nd year of use. This in vitro study showed that the framework association between cast clasp and an extra resilient attachment are suitable to the three metals evaluated, but strongly suggest extra

  4. The use of trivalent chromium bath to obtain a solar selective black chromium coating

    NASA Astrophysics Data System (ADS)

    Survilienė, S.; Češūnienė, A.; Juškėnas, R.; Selskienė, A.; Bučinskienė, D.; Kalinauskas, P.; Juškevičius, K.; Jurevičiūtė, I.

    2014-06-01

    Black chromium coatings were electrodeposited from a trivalent chromium bath using a ZnO additive as a second main component. Black chromium was electrodeposited on steel and copper plates and substrates plated with bright nickel prior to black chromium electrodeposition. The black chromium coatings were characterized by XRD and SEM. The XRD data suggest that the phase structure of black chromium may be defined as a zinc solid solution in chromium or a chromium solid solution in zinc depending on the chromium/zinc ratio in the deposit. The role of substrate finish was evaluated through the corrosion resistance and reflectance of black chromium. According to corrosion tests the samples plated with bright nickel prior to black chromium deposition have shown the highest corrosion resistance. The electrodeposited black chromium possesses good optical properties for the absorption of solar energy. The absorption coefficient of black chromium was found to be over 0.99 for the samples obtained without the Ni undercoat and below 0.99 for those obtained with the use of Ni undercoat. However, the use of nickel undercoat before black chromium plating is recommended because it remarkably improves the corrosion resistance of samples.

  5. Techniques for Achieving Zero Stress in Thin Films of Iridium, Chromium, and Nickel

    NASA Technical Reports Server (NTRS)

    Broadway, David M.; O'Dell, Stephen L.; Ramsey, Brian D.; Weimer, Jeffrey

    2015-01-01

    We examine techniques for achieving zero intrinsic stress in thin films of iridium, chromium, and nickel deposited by magnetron sputter deposition. The intrinsic stress is further correlated to the microstructural features and physical properties such as surface roughness and optical density at a scale appropriate to soft X-ray wavelengths. The examination of the stress in these materials is motivated by efforts to advance the optical performance of light-weight X-ray space telescopes into the regime of sub-arcsecond resolution through various deposition techniques that rely on control of the film stress to values within 10-100 MPa. A characteristic feature of the intrinsic stress behavior in chromium and nickel is their sensitivity to the magnitude and sign of the intrinsic stress with argon gas pressure and deposition rate, including the existence of a critical argon process pressure that results in zero film stress which scales linearly with the atomic mass of the sputtered species. While the effect of stress reversal with argon pressure has been previously reported by Hoffman and others for nickel and chromium, we report this effect for iridium. In addition to stress reversal, we identify zero stress in the optical functioning iridium layer shortly after island coalescence for low process pressures at a film thickness of approximately 35nm. The measurement of the low values of stress during deposition was achieved with the aid of a sensitive in-situ instrument capable of a minimum detectable level of stress, assuming a 35nm thick film, in the range of 0.40-6.0 MPa for <111> oriented crystalline silicon substrate thicknesses of 70-280 microns, respectively.

  6. Hydrogen halide cleaning of powder metallurgy nickel-20 chromium-3 thoria.

    NASA Technical Reports Server (NTRS)

    Herbell, T. P.

    1972-01-01

    The Cr2O3 content of powder metallurgy nickel-20 chromium-3 thoria was reduced with atmospheres consisting of hydrogen plus hydrogen chloride (HCl) or hydrogen bromide (HBr). The nonthoria oxygen content or 'oxygen excess' was reduced from an initial amount of greater than 50,000 ppm to less than 100 ppm. Low temperatures were effective, but lowest oxygen levels were achieved with the highest cleaning temperature of 1200 C.

  7. Assessment of chromium and nickel levels in surface sea waters and sediments from industrial marine area in Tuzla Aydinli Bay, Istanbul Turkey.

    PubMed

    Baysal, Asli; Akman, Suleyman

    2018-05-01

    The determination and evaluation of nickel and chromium in Tuzla Aydinli Bay is an important subject since it is an industrial marine area for decades and it is crucial to protect aquatic life which are toxic for the aqueous environment. In this study, 32 samples were collected both from near the coastal shipyard activity to far of the activity areas in Tuzla Aydinli Bay, Istanbul (Turkey) according to the standard guidance. Nickel and chromium were determined in the sea water and sediment samples by graphite furnace atomic absorption spectrometry. The contamination factors and geoaccumulation indices with respect to nickel and chromium were calculated and evaluated. Based on the modified ecological risk assessments, variable results were obtained depending on the selection of control (blank) points. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Electrochemical polishing of thread fastener test specimens of nickel-chromium iron alloys

    DOEpatents

    Kephart, Alan R.

    1991-01-01

    An electrochemical polishing device and method for selective anodic dissolution of the surface of test specimens comprised, for example, of nickel-chromium-iron alloys, which provides for uniform dissolution at the localized sites to remove metal through the use of a coiled wire electrode (cathode) placed in the immediate proximity of the working, surface resulting in a polished and uniform grain boundary.

  9. In vitro and in vivo corrosion evaluation of nickel-chromium- and copper-aluminum-based alloys.

    PubMed

    Benatti, O F; Miranda, W G; Muench, A

    2000-09-01

    The low resistance to corrosion is the major problem related to the use of copper-aluminum alloys. This in vitro and in vivo study evaluated the corrosion of 2 copper-aluminum alloys (Cu-Al and Cu-Al-Zn) compared with a nickel-chromium alloy. For the in vitro test, specimens were immersed in the following 3 corrosion solutions: artificial saliva, 0.9% sodium chloride, and 1.0% sodium sulfide. For the in vivo test, specimens were embedded in complete dentures, so that one surface was left exposed. The 3 testing sites were (1) close to the oral mucosa (partial self-cleaning site), (2) surface exposed to the oral cavity (self-cleaning site), and (3) specimen bottom surface exposed to the saliva by means of a tunnel-shaped perforation (non-self-cleaning site). Almost no corrosion occurred with the nickel-chromium alloy, for either the in vitro or in vivo test. On the other hand, the 2 copper-aluminum-based alloys exhibited high corrosion in the sulfide solution. These same alloys also underwent high corrosion in non-self-cleaning sites for the in vivo test, although minimal attack was observed in self-cleaning sites. The nickel-chromium alloy presented high resistance to corrosion. Both copper-aluminum alloys showed considerable corrosion in the sulfide solution and clinically in the non-self-cleaning site. However, in self-cleaning sites these 2 alloys did not show substantial corrosion.

  10. Packed-bed column biosorption of chromium(VI) and nickel(II) onto Fenton modified Hydrilla verticillata dried biomass.

    PubMed

    Mishra, Ashutosh; Tripathi, Brahma Dutt; Rai, Ashwani Kumar

    2016-10-01

    The present study represents the first attempt to investigate the biosorption potential of Fenton modified Hydrilla verticillata dried biomass (FMB) in removing chromium(VI) and nickel(II) ions from wastewater using up-flow packed-bed column reactor. Effects of different packed-bed column parameters such as bed height, flow rate, influent metal ion concentration and particle size were examined. The outcome of the column experiments illustrated that highest bed height (25cm); lowest flow rate (10mLmin(-1)), lowest influent metal concentration (5mgL(-1)) and smallest particle size range (0.25-0.50mm) are favourable for biosorption. The maximum biosorption capacity of FMB for chromium(VI) and nickel(II) removal were estimated to be 89.32 and 87.18mgg(-1) respectively. The breakthrough curves were analyzed using Bed Depth Service Time (BDST) and Thomas models. The experimental results obtained agree to both the models. Column regeneration experiments were also carried out using 0.1M HNO3. Results revealed good reusability of FMB during ten cycles of sorption and desorption. Performance of FMB-packed column in treating secondary effluent was also tested under identical experimental conditions. Results demonstrated significant reduction in chromium(VI) and nickel(II) ions concentration after the biosorption process. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. High strength nickel-chromium-iron austenitic alloy

    DOEpatents

    Gibson, Robert C.; Korenko, Michael K.

    1980-01-01

    A solid solution strengthened Ni-Cr-Fe alloy capable of retaining its strength at high temperatures and consisting essentially of 42 to 48% nickel, 11 to 13% chromium, 2.6 to 3.4% niobium, 0.2 to 1.2% silicon, 0.5 to 1.5% vanadium, 2.6 to 3.4% molybdenum, 0.1 to 0.3% aluminum, 0.1 to 0.3% titanium, 0.02 to 0.05% carbon, 0.002 to 0.015% boron, up to 0.06 zirconium, and the balance iron. After solution annealing at 1038.degree. C. for one hour, the alloy, when heated to a temperature of 650.degree. C., has a 2% yield strength of 307 MPa, an ultimate tensile strength of 513 MPa and a rupture strength of as high as 400 MPa after 100 hours.

  12. Assessment of Changes in Nickel and Chromium Levels in the Gingival Crevicular Fluid during Fixed Orthodontic Treatment.

    PubMed

    Bhasin, Vinny; Pustake, Swati J; Joshi, Viprat; Tiwari, Anil; Bhasin, Meenakshi; Punia, Ramandeep S

    2017-08-01

    Various components of appliances used in fixed orthodontic treatment are fabricated from materials that are highly resistant in nature and have high strength and biocompatibility. Corrosion of materials occurs inside the oral cavity due to numerous environmental or oral factors that act on them. These factors include temperature, pH variation, salivary conditions, mechanical loads, microbiological and enzymatic activity, and various food components. Gingival crevicular fluid (GCF) is the material obtained from the gingival sulcus and might act as a potential source for various biomarkers in the orthodontic setup because inflammatory-induced response is directly related to orthodontic forces in GCF. In the light of above-mentioned data, we planned this study to assess and evaluate the changes occurring in nickel and chromium levels in the GCF during fixed orthodontic treatment. This study included assessment of 30 patients who underwent fixed orthodontic treatment. Three samples were taken from the GCF of the patients giving a total of 90 samples. The samples were collected at the following time intervals: At baseline (pretreatment time), 1 month after the start of orthodontic treatment, and at 6 months after the commencement of orthodontic treatment. Cellulose strips were used for isolation of the tooth region. For GCF collection, a standardized cellulose acetate absorbent strip was used. Placement of the strips was done in the sulcus for 60 seconds for the collection of the samples. Refrigeration of the specimen bottles was done for a minimum of 7 days and was then sent to a laboratory where specimens were transferred for atomic absorption spectrophotometry. All the results were analyzed by Statistical Package for the Social Sciences software. At 1 month, the mean value of nickel and chromium in GCF was found to be 4.5 and 4.9 ug/gm of GCF respectively. While comparing the mean nickel levels between 1 and 6 months and between baseline and 6 months, significant

  13. Effects of fixed orthodontic treatment on nickel and chromium levels in gingival crevicular fluid as a novel systemic biomarker of trace elements: A longitudinal study.

    PubMed

    Amini, Fariborz; Shariati, Mahsa; Sobouti, Farhad; Rakhshan, Vahid

    2016-05-01

    Nickel and chromium might induce hypersensitivity. Therefore, they are of interest to orthodontists. Gingival crevicular fluid (GCF) is highly relevant to orthodontic treatments and might reflect systemic changes associated with the inflammatory response induced by orthodontic forces. Therefore, it might also be used to show metal ion changes. Nevertheless, baseline metal levels of GCF are unknown, and the effect of orthodontic treatment on GCF metal levels has not been investigated. The aim of this study was to assess the levels of nickel and chromium in GCF. Based on a pilot study, the sample size was predetermined as 24 × 3 measurements to obtain test powers above 90%. Nickel and chromium concentrations were measured before treatment and 1 month and 6 months later in 12 female and 12 male patients who had fixed orthodontic appliances using atomic absorption spectrophotometry. The gingival index was also evaluated in each session. The effects of treatment on GCF ions were analyzed using repeated-measures analysis of variance and Friedman tests (α = 0.05, β ≤0.01). The gingival index worsened over time (chi-square test, P <0.001). The mean nickel levels were 3.894 ± 1.442, 5.913 ± 2.735, and 19.810 ± 8.452 μg per gram, respectively, at baseline, month 1, and month 6. Chromium concentrations were 1.978 ± 0.721, 4.135 ± 1.591, and 13.760 ± 3.555 μg per gram, respectively. Compared with the baseline, nickel increased by 150% and 510%, respectively, in the first and sixth months (Friedman, P <0.0001), and chromium increased by 200% and 700%, respectively (analysis of variance, P <0.0001). Six months of fixed orthodontic treatment might intensify the levels of nickel and chromium in the GCF as well as gingival inflammation. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  14. Experimental exposure of healthy subjects with emissions from a gas metal arc welding process--part II: biomonitoring of chromium and nickel.

    PubMed

    Gube, Monika; Brand, Peter; Schettgen, Thomas; Bertram, Jens; Gerards, Kerstin; Reisgen, Uwe; Kraus, Thomas

    2013-01-01

    The objective of this study was to investigate whether there is a relationship between the external exposure dose of chromium and nickel caused by a metal active gas welding process with a solid high-alloyed steel welding wire and inner exposure of subjects. In order to perform welding fume exposure under controlled and standardized conditions, the investigations were conducted in the "Aachen Workplace Simulation Laboratory". To perform biological monitoring of chromium and nickel, blood and urine samples of 12 healthy male non-smokers who never worked as welders were collected before and after a 6-h exposure to ambient air (0 mg/m(3)) and to welding fumes of a metal active gas welding process once with a concentration of the welding fume of 1 mg/m(3) and once with a concentration of 2.5 mg/m(3). Although the internal exposure to chromium and nickel in this study was comparatively low, the subjects showed significantly increased concentrations of these metals in urine after exposure to welding fume compared to the values at baseline. Moreover, the observed increase was significantly dose dependent for both of the substances. For the biological monitoring of chromium and nickel in urine of subjects exposed to welding fumes, a dependency on exposure dose was seen under standardized conditions after a single exposure over a period of 6 h. Thus, this study contributes to a better understanding of the relationship between ambient and biological exposures from welding fumes and provides a good basis for evaluating future biological threshold values for these metals in welding occupation.

  15. Effects of Restoring the Primary Dentition with Stainless-Steel Crowns on Children's Salivary Nickel and Chromium Levels, and the Associations with Saliva pH: a Preliminary Before-After Clinical Trial.

    PubMed

    Basir, Leila; Meshki, Razieh; Behbudi, Azam; Rakhshan, Vahid

    2018-05-23

    Nickel and chromium existing in stainless-steel crowns (SSCs, used in pediatric dentistry) might be cytotoxic and allergenic. However, no in vivo studies have examined their salivary levels in children using SSCs, or in young children without SSCs. Also, the effect of acidity on metal ion release has not yet been evaluated in any previous in vivo studies in the whole literature. Therefore, this preliminary before-after clinical trial was conducted. Salivary nickel/chromium levels of 30 children before and after 2 months of placement of SSCs were measured using atomic absorption spectrophotometry. Salivary pH was measured with a digital pH meter. The effects of treatment, pH, number of SSCs, gender, and age on salivary ions were analyzed statistically (α = 0.05, β = 0.15). Salivary nickel concentrations increased from 4.9010 ± 4.7390 to 5.6320 ± 4.7210 μg/L (P = 0.000, paired t test). Chromium increased from 0.3273 ± 0.5214 to 0.4199 ± 0.6404 μg/L (P = 0.016). Saliva pH increased from 6.81 ± 0.52 to 7.04 ± 0.47 (P = 0.000). Ion levels were not correlated with pH (P > 0.14), except chromium in the follow-up (rho = - 0.435, P = 0.016). Nickel increase (but not chromium increase) was correlated with pH increase (rho = 0.367, P = 0.046). Age was only correlated with baseline chromium (rho = 0.373, P = 0.042). Being male was associated with baseline/follow-up nickel levels (P ≤ 0.030). SSC number was not correlated with ions or pH (P > 0.36). It was shown for the first time that SSCs might increase salivary nickel and chromium concentrations and reduce saliva acidity. Nickel increase might be in line with pH elevation. The raised pH might be associated with reduced chromium release. Boys might have higher nickel levels than might girls, with or without SSCs.

  16. Effect of Particle Morphology on Cold Spray Deposition of Chromium Carbide-Nickel Chromium Cermet Powders

    NASA Astrophysics Data System (ADS)

    Fernandez, Ruben; Jodoin, Bertrand

    2017-08-01

    Nickel chromium-chromium carbide coatings provide good corrosion and wear resistance at high temperatures, making them ideal for applications where a harsh environment and high temperatures are expected. Thermal spray processes are preferred as deposition technique of cermets, but the high process temperatures can lead to decarburization and reduction of the coatings properties. Cold spray uses lower temperatures preventing decarburization. Since the metallic phase remains solid, the feedstock powder morphology becomes crucial on the deposition behavior. Six commercially available powders were studied, varying in morphology and metal/ceramic ratios. The powders were categorized into 4 groups depending on their morphology. Spherical powders lead to substrate erosion due to their limited overall ductility. Porous agglomerated and sintered powders lead to severely cracked coatings. For dense agglomerated and sintered powders, the outcome depended on the initial metal/ceramic ratio: powders with 25 wt.% NiCr led to substrate erosion while 35 wt.% NiCr powders led to dense coatings. Finally, blended ceramic-metal mixtures also lead to dense coatings. All coatings obtained had lower ceramic content than the initial feedstock powders. Interrupted spray tests, combined with FEA, helped drawing conclusions on the deposition behavior to explain the obtained results.

  17. Effect of Low Nickel Dopant on Torque Transducer Response Function in High-Chromium Content ESR Stainless Tool Steels

    NASA Astrophysics Data System (ADS)

    Wiewel, Joseph L.; Hecox, Bryan G.; Orris, Jason T.; Boley, Mark S.

    2007-03-01

    The change in magnetoelastic torque transducer response was investigated as a low nickel content (up to 0.2%) is alloyed into an ESR (Electro-Slag-Refining) stainless tool steel with a chromium content of around 13%, which our previous studies have proven to be the ideal level of chromium content for optimal transducer performance. Two separate hollow steel 3/4-inch diameter shafts were prepared from ESR 416 and ESR 420 steel, respectively, the first having no nickel content and the second having 0.2% nickel content. The heat treatment of these steels consisted of a hardening process conducted in a helium atmosphere at 1038^oC, followed by an annealing at 871^oC for 5h and a 15^oC cool down rate. Prior and subsequent to the heat treatment processes, the circumferential and axial magnetic hysteresis properties of the samples were measured and their external field signals were mapped over the magnetically polarized regions both with and without applied shear stress up to 2500 psi on the samples. It was found that the effect of the low nickel dopant was to improve torque transducer sensitivity and linearity, but heat treatment worsened the performance of both samples.

  18. Biodegradation of orthodontic appliances and their effects on the blood level of nickel and chromium. Master's thesis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barrett, R.D.

    1990-05-01

    Austenitic stainless steels containing approximately 18 percent chromium and 8 percent nickel for orthodontic bands, brackets and wires is universally used in orthodontic practices. With the introduction of nickel-titanium alloys as orthodontic archwires in the 1970's an additional source of patient exposure to metal corrosion products has been introduced. Since the oral environment is particularly ideal for the biodegradation of metals due to its ionic, thermal, microbiologic and enzymatic properties some level of patient exposure to the corrosion products of these alloys is assured.

  19. Microstructure and properties of cryomilled nickel aluminide extruded with chromium or molybdenum

    NASA Technical Reports Server (NTRS)

    Aikin, Beverly J. M.; Dickerson, Robert M.; Dickerson, Patricia O.

    1995-01-01

    Previous results from high energy, attrition milled NiAl in liquid nitrogen (cryomilled) indicate that this process can produce high temperature, creep resistant AlN particulate reinforced materials. However, the low temperature toughness of such materials is below that preferred for structural applications in aerospace engines. In order to improve the toughness of these materials, prealloyed nickel aluminide (Ni-53 atomic percent Al) powder was cryomilled and mixed with chromium or molybdenum powders. The resulting materials were hot extruded and tested for room temperature toughness and 1300 K compressive strength.

  20. Nickel oxide decorated zinc oxide composite nanorods: Excellent catalyst for photoreduction of hexavalent chromium.

    PubMed

    Singh, Simranjeet; Ahmed, Imtiaz; Haldar, Krishna Kanta

    2018-08-01

    In light of the growing interest and ability to search for new materials, we have synthesized Nickel oxide (NiO) nanoparticles decorated Zinc (ZnO) nanorods composite (NiO/ZnO) nanostructure. The NiO/ZnO heterostructure formation was confirmed by X-ray powder diffraction and high-resolution transmission electron microscopy (HRTEM). The fabricated environmental friendly NiO/ZnO composite nanostructure shows a well-defined photoreduction characteristic of hexavalent Chromium (Cr) (VI) to tri-valent Chromium (Cr) (III) under UV-light. Such an enhanced photoreduction property is attributed due to the decreased electron-hole recombination process which was proved by photoluminescence (PL) spectroscopy, photocurrent study, and electrochemical impedance spectroscopy. Furthermore, the photocatalytic activity rate of the NiO decorated ZnO nanorods was much higher than that of bare ZnO nanorods for the reduction of chromium (VI) and the rate is found to be 0.306 min -1 . These results have demonstrates that suitable surface engineering may open up new opportunities in the development of high-performance photocatalyst. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. Heavy metal pollution among autoworkers. II. Cadmium, chromium, copper, manganese, and nickel.

    PubMed Central

    Clausen, J; Rastogi, S C

    1977-01-01

    Garages and auto-repair workshops may be polluted with other heavy metals besides lead. Blood of autoworkers with high lead content was analysed for cadmium, chromium, copper manganese, nickel, ALAD activity and carboxyhaemoglobin level. Cadmium and copper levels in blood of autoworkers were comparable with those of the control subjects while chroimium and nickel levels were significantly higher (P less than 0-01 for both metals), and scattered raised values of manganese were found. There was no significant mutual correlation between levels of various heavy metals determined in whole blood. High copper levels were slightly related to decreasing ALAD activity (P less than 0-1). Nineteen per cent of autoworkers were found to have an abnormally blood level of carboxyhaemoglobin. The amount of particulate heavy metal in autoworkshop air was not related to biochemical abnormalities found in the autoworkers. Various sources of pollution of these heavy metals in autoworkshops are discussed. PMID:71915

  2. Absorption of nickel, chromium, and iron by the root surface of primary molars covered with stainless steel crowns.

    PubMed

    Keinan, David; Mass, Eliyahu; Zilberman, Uri

    2010-01-01

    Objective. The purpose of this study was to analyze the absorption of metal ions released from stainless steel crowns by root surface of primary molars. Study Design. Laboratory research: The study included 34 primary molars, exfoliated or extracted during routine dental treatment. 17 molars were covered with stainless-steel crowns for more than two years and compared to 17 intact primary molars. Chemical content of the mesial or distal root surface, 1 mm apically to the crown or the cemento-enamel junction (CEJ), was analyzed. An energy dispersive X-ray spectrometer (EDS) was used for chemical analysis. Results. Higher amounts of nickel, chromium, and iron (5-6 times) were found in the cementum of molars covered with stainless-steel crowns compared to intact molars. The differences between groups were highly significant (P < .001). Significance. Stainless-steel crowns release nickel, chromium, and iron in oral environment, and the ions are absorbed by the primary molars roots. The additional burden of allergenic metals should be reduced if possible.

  3. Chromium release from new stainless steel, recycled and nickel-free orthodontic brackets.

    PubMed

    Sfondrini, Maria Francesca; Cacciafesta, Vittorio; Maffia, Elena; Massironi, Sarah; Scribante, Andrea; Alberti, Giancarla; Biesuz, Raffaela; Klersy, Catherine

    2009-03-01

    To test the hypothesis that there is no difference in the amounts of chromium released from new stainless steel brackets, recycled stainless steel brackets, and nickel-free (Ni-free) orthodontic brackets. This in vitro study was performed using a classic batch procedure by immersion of the samples in artificial saliva at various acidities (pH 4.2, 6.5, and 7.6) over an extended time interval (t(1) = 0.25 h, t(2) = 1 h, t(3) = 24 h, t(4) = 48 h, t(5) = 120 h). The amount of chromium release was determined using an atomic absorption spectrophotometer and an inductively coupled plasma atomic emission spectrometer. Statistical analysis included a linear regression model for repeated measures, with calculation of Huber-White robust standard errors to account for intrabracket correlation of data. For post hoc comparisons the Bonferroni correction was applied. The greatest amount of chromium was released from new stainless steel brackets (0.52 +/- 1.083 microg/g), whereas the recycled brackets released 0.27 +/- 0.38 microg/g. The smallest release was measured with Ni-free brackets (0.21 +/- 0.51 microg/g). The difference between recycled brackets and Ni-free brackets was not statistically significant (P = .13). For all brackets, the greatest release (P = .000) was measured at pH 4.2, and a significant increase was reported between all time intervals (P < .002). The hypothesis is rejected, but the amount of chromium released in all test solutions was well below the daily dietary intake level.

  4. NICKEL COATED URANIUM ARTICLE

    DOEpatents

    Gray, A.G.

    1958-10-01

    Nickel coatings on uranium and various methods of obtaining such coatings are described. Specifically disclosed are such nickel or nickel alloy layers as barriers between uranium and aluminum- silicon, chromium, or copper coatings.

  5. Μetal Uptake by Sunflower (Helianthus annuus) Irrigated with Water Polluted with Chromium and Nickel.

    PubMed

    Stoikou, Vasiliki; Andrianos, Vangelis; Stasinos, Sotiris; Kostakis, Marios G; Attiti, Sofia; Thomaidis, Nikolaos S; Zabetakis, Ioannis

    2017-07-17

    The water aquifers of the regions of Asopos River in Viotia and Messapia in Evia (Greece) have been contaminated with hexavalent chromium (Cr (VI)) and bivalent nickel (Ni (II)). Given that these areas are the two biggest tuber producing regions of Greece, in our previous work, the cross-contamination of the food chain with these two heavy metals was quantified. In the present study, the potential of sunflower ( Helianthus annuus ) cultivation in these regions is evaluated. The scope of our study was to investigate the uptake of chromium and nickel by sunflower, in a greenhouse experiment. The study included two cultivation periods of plants in six irrigation lines with different levels of Cr (VI) and Ni (II) ranging from 0 μg/L (control) to 10,000 μg/L. In all plant parts, statistically significant increased levels of Cr (VI) and Ni (II) were found when compared to control ones. Also, a positive correlation, both for Cr and Ni, between levels of heavy metals in irrigation water and plants was observed. Following European Food Safety Authority recommendations, the obtained oil was evaluated as safe for consumption, therefore, sunflower cultivation could be a valid bioremediation solution for the Asopos and Messapia regions.

  6. Μetal Uptake by Sunflower (Helianthus annuus) Irrigated with Water Polluted with Chromium and Nickel

    PubMed Central

    Stoikou, Vasiliki; Andrianos, Vangelis; Stasinos, Sotiris; Kostakis, Marios G.; Attiti, Sofia; Zabetakis, Ioannis

    2017-01-01

    The water aquifers of the regions of Asopos River in Viotia and Messapia in Evia (Greece) have been contaminated with hexavalent chromium (Cr (VI)) and bivalent nickel (Ni (II)). Given that these areas are the two biggest tuber producing regions of Greece, in our previous work, the cross-contamination of the food chain with these two heavy metals was quantified. In the present study, the potential of sunflower (Helianthus annuus) cultivation in these regions is evaluated. The scope of our study was to investigate the uptake of chromium and nickel by sunflower, in a greenhouse experiment. The study included two cultivation periods of plants in six irrigation lines with different levels of Cr (VI) and Ni (II) ranging from 0 μg/L (control) to 10,000 μg/L. In all plant parts, statistically significant increased levels of Cr (VI) and Ni (II) were found when compared to control ones. Also, a positive correlation, both for Cr and Ni, between levels of heavy metals in irrigation water and plants was observed. Following European Food Safety Authority recommendations, the obtained oil was evaluated as safe for consumption, therefore, sunflower cultivation could be a valid bioremediation solution for the Asopos and Messapia regions. PMID:28714908

  7. Evaluation of Beryllium, Total Chromium and Nickel in the Surface Contaminant Layer Available for Dermal Exposure After Abrasive Blasting in a Shipyard

    DTIC Science & Technology

    2013-04-24

    established to minimize the potential of dermal irritation and dermatitis (6). Chromium exposure can lead to allergic contact dermatitis , irritant... dermatitis with skin contact . (5; 15; 25; 33; 47). Nickel is potentially the most common contact allergen among the general population. Some studies...thresholds - a review focusing on occluded nickel exposure. Contact Dermatitis 52:57-64 21. Fogh CL, Andersson KG. 2000. Modelling of skin exposure

  8. Relation of structure to mechanical properties of thin thoria dispersion strengthened nickel-chromium (TD-NiCr alloy sheet

    NASA Technical Reports Server (NTRS)

    Whittenberger, J. D.

    1975-01-01

    A study of the relation between structure and mechanical properties of thin TD-NiCr sheet indicated that the elevated temperature tensile, stress-rupture, and creep strength properties depend primarily on the grain aspect ratio and sheet thickness. In general, the strength properties increased with increasing grain aspect ratio and sheet thickness. Tensile testing revealed an absence of ductility at elevated temperatures. A threshold stress for creep appears to exist. Even small amounts of prior creep deformation at elevated temperatures can produce severe creep damage.

  9. Exposure to Nickel, Chromium, or Cadmium Causes Distinct Changes in the Gene Expression Patterns of a Rat Liver Derived Cell Line

    DTIC Science & Technology

    2011-11-16

    protein A (Rpa2), the minichromosome maintenance complex component genes which encode helicases, DNA ligase (Lig1), DNA polymerase e ( Pole and Pole2...and DNA polymerase d ( Pold1 and Pold2 ) are all up-regulated as a result of exposure to chromium (Figure 6), suggesting that there is an increase in...Exposure to Nickel, Chromium, or Cadmium Causes Distinct Changes in the Gene Expression Patterns of a Rat Liver Derived Cell Line Matthew G

  10. Mineral resource of the month: nickel

    USGS Publications Warehouse

    Kuck, Peter H.

    2006-01-01

    Together with chromium, nickel makes steel more resistant to corrosion. Stainless steel thus accounts for more than 65 percent of primary nickel consumption in the world. One of the more common grades of stainless steel is Type 304, which contains 18 to 20 percent chromium and 10.5 to 12 percent nickel. Owing to their high corrosion resistance, nickel-bearing stainless steels are widely used in the transportation sector, the energy sector, the food preparation and processing industry, the beverage industry, the pharmaceutical industry and the medical community.

  11. Nickel aluminides and nickel-iron aluminides for use in oxidizing environments

    DOEpatents

    Liu, Chain T.

    1988-03-15

    Nickel aluminides and nickel-iron aluminides treated with hafnium or zirconium, boron and cerium to which have been added chromium to significantly improve high temperature ductility, creep resistance and oxidation properties in oxidizing environments.

  12. Activation of MAP kinases by hexavalent chromium, manganese and nickel in human lung epithelial cells.

    PubMed

    Tessier, Daniel M; Pascal, Laura E

    2006-12-01

    Epidemiological studies indicate that workers who perform welding operations are at increased risk for bronchitis, siderosis, occupational asthma and lung cancer due to fume exposure. Welding fumes are a complex chemical mixture, and the metal composition is hypothesized to be an etiological factor in respiratory disease due to this exposure. In the present study, human lung epithelial cells in vitro responded to hexavalent chromium, manganese and nickel over a concentration range of 0.2-200 microM with a significant increase in intracellular phosphoprotein (a measure of stress response pathway activation). The mitogen-activated protein kinases ERK1/2, SAPK/JNK and p38 were activated via phosphorylation following 1-h exposures. Hexavalent chromium up-regulated p-38 phosphorylation 23-fold and SAPK/JNK phosphorylation 17-fold, with a comparatively modest 4-fold increase in ERK1/2 phosphorylation. Manganese caused a two- to four-fold increase in SAPK/JNK and ERK 1/2 phosphorylation, with no observed effects on p38 kinase. Nickel caused increased (two-fold) phosphorylation of ERK 1/2 only, and was not cytotoxic over the tested concentration range. The observed effects of welding fume metals on cellular signaling in lung epithelium demonstrate a potentially significant interplay between stress-response signaling (p38 and SAPK/JNK) and anti-apototic signaling (ERK 1/2) that is dependant on the specific metal or combination of metals involved.

  13. Effects of fixed orthodontic treatment using conventional (two-piece) versus metal injection moulding brackets on hair nickel and chromium levels: a double-blind randomized clinical trial.

    PubMed

    Khaneh Masjedi, Mashallah; Haghighat Jahromi, Nima; Niknam, Ozra; Hormozi, Elham; Rakhshan, Vahid

    2017-02-01

    Although nickel and chromium are known as allergen and cytotoxic orthodontic metals, very few and controversial studies have assessed the effect of orthodontic treatment on their systemic levels especially those reflected by their best biomarker of exposure, hair. Additionally, metal injection moulding (MIM) brackets are not studied, and there is no study on systemic ion changes following their usage. In this double-blind randomized clinical trial, scalp hair samples of 24 female and 22 male fixed orthodontic patients [as two groups of conventional (two-piece) versus MIM brackets, n = 23×2] were collected before treatment and 6 months later. Randomization was carried out using a computer-generated random number table. The patients, laboratory expert, and author responsible for analyses were blinded of the bracket allocations. Hair nickel and chromium levels were measured using atomic absorption spectrophotometry. The effects of treatment, bracket types, gender, and age on hair ions were analysed statistically (α = 0.05, β ≤ 0.02). In both groups combined (n = 46), nickel increased from 0.1600±0.0890 µg/g dry hair mass (pre-treatment) to 0.3199±0.1706 (6th month). Chromium increased from 0.1657±0.0884 to 0.3066±0.1362 µg/g. Both of these increases were significant (paired t-test, P = 0.0000). Bracket types, age, and gender had no significant influence on ion levels (P > 0.05). ANCOVA indicated different patterns of chromium increases in different genders (P = 0.033) and ages (P = 0.056). Sample size determination should have accounted for the grouping as well. Hair nickel and chromium levels might increase about 185-200% after 6 months. They might not be affected by bracket types. Gender and age might not influence the baseline or 6th-month levels of both metals. Gender might however interact with orthodontic treatment, only in the case of chromium. The research is registered offline (thesis) and online (IR.AJUMS.REC.1394.516). The protocol was pre

  14. Active-passive corrosion of iron-chromium-nickel alloys in hot concentrated sulphuric acid solutions

    NASA Astrophysics Data System (ADS)

    Kish, Joseph R.

    1999-11-01

    In the manufacture of sulphuric acid more stringent environmental standards and operation economics have forced the industry to improve product utilization, energy efficiency and reliability. A key to improving both the thermal efficiency and reliability is the use and/or development of more corrosion resistance materials including stainless steels, especially in the parts of the plant that handle the condensed acid. Application of more corrosion resistant material requires a better understanding of the corrosion mechanism involved in concentrated H2SO4-H2O (>90 wt.%) solutions. While corrosion kinetics of carbon steel, the traditional material of construction, are relatively well understood, this is much less true in the case of the cyclic active-passive corrosion of stainless steels. Models proposed to explain the cyclic active-passive corrosion involve a periodic formation of either a protective metal sulphate film or an insoluble sulphur layer. To better understand the reactivity and/or passivity of stainless steel in concentrated H2SO4-H2O solutions a study employing immersion and electrochemical techniques, including rotating electrodes, was conducted in order to clarify the following: (1) The state of stainless steel passivity. (2) The conditions in which passivity is stable. (3) The role played by the major alloying elements in establishing and maintaining the passive state. The study involved evaluating the corrosion behaviour of stainless steels S30403 and S43000 along with iron, chromium and nickel in 93.5 wt.% H2SO4 at temperatures between 25--80°C. Major discoveries of the study include: (1) A content of 17--18 wt.% chromium is sufficient to anodically passivate S43000 as the potential is made more noble. Passivity is not stable and requires anodic polarization. (2) Alloyed nickel plays an active role in improving the corrosion resistance of stainless steel. A content of 8 wt.% nickel is sufficient promote a periodic passivation of the base Fe-(17

  15. Evaluation of the genotoxic effects of fixed appliances on oral mucosal cells and the relationship to nickel and chromium concentrations: an in-vivo study.

    PubMed

    Natarajan, Madhumitha; Padmanabhan, Sridevi; Chitharanjan, Arun; Narasimhan, Malathi

    2011-09-01

    The release of metal ions from fixed orthodontic appliances is a source of concern. The aim of this study was to evaluate genotoxic damage in the oral mucosal cells of patients wearing fixed appliance, and the nickel and chromium ion contents in these cells. Twenty patients undergoing orthodontic treatment formed the experimental group, and 20 untreated subjects comprised the control group. Oral mucosal smears were collected at 2 times: at debonding and 30 days after debonding. The smears were stained with Papanicolaou stain and studied under a light microscope to evaluate the presence of micronuclei. Inductively coupled plasma-mass spectrometry was used to quantify the presence of metal ions. The data were subjected to the Mann-Whitney U test and the Spearman rank correlation test. The mean micronuclei frequency was significantly higher in the treated group than in the control group at debonding; the difference was smaller and not statistically significant 30 days after debonding. The nickel and chromium ion contents in the experimental group were not significantly higher than in the control group. No correlation could be established between micronuclei frequency and metal ion content. Nickel and chromium alloys of orthodontic appliances emit metal ions in sufficient quantities to induce localized genotoxic effects, but these changes revert on removal of the appliances. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  16. Genotoxic effects of nickel, trivalent and hexavalent chromium on the Eisenia fetida earthworm.

    PubMed

    Bigorgne, Emilie; Cossu-Leguille, Carole; Bonnard, Marc; Nahmani, Johanne

    2010-08-01

    The aim of this study was to examine genotoxic effects of nickel (Ni=105 mg kg(-1)), trivalent and hexavalent chromium (Cr=491 mg kg(-1)) on the Eisenia fetida earthworm after 2 and 4d of exposure to two different spiked soils (an artificial (OECD) and a natural one). DNA damages were evaluated on the earthworm's coelomocytes using the comet assay. After an exposure into OECD spiked soils, Ni did not induce genotoxic effect whereas Cr(III) and Cr(VI) revealed to be genotoxic after 2d of exposure. After 4d of exposure, only Cr(VI) still induced significant damages. In natural spiked soils, nickel and Cr(III) revealed to be genotoxic after 2 and 4d of exposure. Concerning Cr(VI) toxicity, all the earthworms died after 1d of exposure. These results underline the importance to take into account the nature and the speciation of metallic pollutants, although the experiment has been performed on spiked soil with higher bioavailibity than in contaminated natural soil. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  17. High gas velocity oxidation and hot corrosion testing of oxide dispersion-strengthened nickel-base alloys

    NASA Technical Reports Server (NTRS)

    Deadmore, D. L.; Lowell, C. E.

    1975-01-01

    Several oxide dispersion strengthened (ODS) nickel-base alloys were tested in high velocity gases for cyclic oxidation resistance at temperatures to 1200 C and times to 500 hours and for hot corrosion resistance at 900 C for 200 hours. Nickel-chromium-aluminum ODS alloys were found to have superior resistance to oxidation and hot corrosion when compared to bare and coated nickel-chromium ODS alloys. The best of the alloys tested had compositions of nickel - 15.5 to 16 weight percent chromium with aluminum weight percents between 4.5 and 5.0. All of the nickel-chromium-aluminum ODS materials experienced small weight losses (less than 16 mg/sq cm).

  18. Comparison of Heavy-Duty Scuffing Behavior between Chromium-Based Ceramic Composite and Nickel-Chromium-Molybdenum-Coated Ring Sliding against Cast Iron Liner under Starvation

    PubMed Central

    Shen, Yan; Yu, Baihong; Lv, Yutao; Li, Bin

    2017-01-01

    A running-in and starved lubrication experiment is designed to investigate the heavy-duty scuffing behavior of piston ring coatings against cast iron (Fe) cylinder liner using the piston ring reciprocating liner test rig. The scuffing resistance of the piston ring with the chromium-based ceramic composite coating (CKS), and that with the thermally sprayed nickel-chromium-molybdenum coating (NCM) is compared at different nominal pressures (40~100 MPa) and temperatures (180~250 °C). With the failure time as a criterion, the rank order is as follows: NCM/Fe > CKS/Fe. Before the scoring occurs at the interface of the piston ring and cylinder liner (PRCL), the cast iron liner enters into a “polish wear” stage, and iron-based adhesive materials begin to form on the piston ring surface. With the macroscopic adhesion formation, the plastic shearing cycle causes surface damages mainly due to abrasive effects for the CKS/Fe pairs and adhesive effects for the NCM/Fe pairs. PMID:29036911

  19. 21 CFR 73.1015 - Chromium-cobalt-aluminum oxide.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) Identity. The color additive chromium-cobalt-aluminum oxide is a blue-green pigment obtained by calcining a... percent each) of oxides of barium, boron, silicon, and nickel. (b) Specifications. Chromium-cobalt... milliliters of 0.5 N hydrochloric acid. (c) Uses and restrictions. The color additive chromium-cobalt-aluminum...

  20. [Nutritive value of daily food rations reproduced in several regions of Poland. Part VII. Evaluation of cobalt, chromium, nickel and selenium intakes].

    PubMed

    Marzec, Z; Buliński, R

    1992-01-01

    On the basis of the data of the Chief Census Bureau, concerning the consumption of more than 80 food products, we reproduced in years 1987 and 1988 in Lublin, Olsztyn, Poznań, Warszawa and Wrocław the food rations characteristic of manual workers' families and of other families with medium incomes. In samples of these diets, chromium, cobalt and nickel were determined by the ASA method, and selenium-spectrophotometrically. Daily intakes were: for cobalt 15-32 micrograms, chromium 65-187 micrograms, nickel 138-316 micrograms and selenium 93-233 micrograms. It was found that the investigated food rations cover the requirements of these elements, and create no risk of their excess in food. The present results indicate that the levels of the investigated elements are mainly related to the kind of food products and to their composition, whereas they depend to a lesser extent on the region in which the food ration has been reproduced.

  1. Speciation studies of nickel and chromium in wastewater from an electroplating plant.

    PubMed

    Kiptoo, Jackson K; Ngila, J Catherine; Sawula, Gerald M

    2004-09-08

    A speciation scheme involving the use of flame atomic absorption spectrometry (FAAS) and differential pulse adsorptive cathodic stripping voltammetry (DPAdCSV) techniques was applied to studies of nickel and chromium in wastewater from a nickel-chrome electroplating plant. Dimethylglyoxime (DMG) and diethylenetriaminepentaacetic acid (DTPA) were employed as complexing agents for adsorptive voltammetric determination of Ni and Cr, respectively. Cr(III) and Cr(VI) were determined by exploiting differences in their reactivity towards DTPA at HMDE. Total dissolved metal content was in the range 2906-3141 and 30.7-31.2mgl(-1) for Ni and Cr, respectively. A higher percentage of the metal was present as labile species (mean value of 67.9% for Ni and 79.8% for Cr) suggesting that strongly binding ligands are not ubiquitous in the sample. About 77.8% of Cr was found to exist in the higher oxidization state, Cr(IV). Results on effect of dilution on lability of the metal forms in the sample using DPAdCSV showed slight peak shifts to a more negative (cathodic) value by -0.036V for Ni and -0.180V for Cr with a dilution factor of 100, while peak intensity (cathodic current) remained fairly constant.

  2. Reliability and validity of expert assessment based on airborne and urinary measures of nickel and chromium exposure in the electroplating industry.

    PubMed

    Chen, Yu-Cheng; Coble, Joseph B; Deziel, Nicole C; Ji, Bu-Tian; Xue, Shouzheng; Lu, Wei; Stewart, Patricia A; Friesen, Melissa C

    2014-11-01

    The reliability and validity of six experts' exposure ratings were evaluated for 64 nickel-exposed and 72 chromium-exposed workers from six Shanghai electroplating plants based on airborne and urinary nickel and chromium measurements. Three industrial hygienists and three occupational physicians independently ranked the exposure intensity of each metal on an ordinal scale (1-4) for each worker's job in two rounds: the first round was based on responses to an occupational history questionnaire and the second round also included responses to an electroplating industry-specific questionnaire. The Spearman correlation (r(s)) was used to compare each rating's validity to its corresponding subject-specific arithmetic mean of four airborne or four urinary measurements. Reliability was moderately high (weighted kappa range=0.60-0.64). Validity was poor to moderate (r(s)=-0.37-0.46) for both airborne and urinary concentrations of both metals. For airborne nickel concentrations, validity differed by plant. For dichotomized metrics, sensitivity and specificity were higher based on urinary measurements (47-78%) than airborne measurements (16-50%). Few patterns were observed by metal, assessment round, or expert type. These results suggest that, for electroplating exposures, experts can achieve moderately high agreement and (reasonably) distinguish between low and high exposures when reviewing responses to in-depth questionnaires used in population-based case-control studies.

  3. Reliability and validity of expert assessment based on airborne and urinary measures of nickel and chromium exposure in the electroplating industry

    PubMed Central

    Chen, Yu-Cheng; Coble, Joseph B; Deziel, Nicole C.; Ji, Bu-Tian; Xue, Shouzheng; Lu, Wei; Stewart, Patricia A; Friesen, Melissa C

    2014-01-01

    The reliability and validity of six experts’ exposure ratings were evaluated for 64 nickel-exposed and 72 chromium-exposed workers from six Shanghai electroplating plants based on airborne and urinary nickel and chromium measurements. Three industrial hygienists and three occupational physicians independently ranked the exposure intensity of each metal on an ordinal scale (1–4) for each worker's job in two rounds: the first round was based on responses to an occupational history questionnaire and the second round also included responses to an electroplating industry-specific questionnaire. Spearman correlation (rs) was used to compare each rating's validity to its corresponding subject-specific arithmetic mean of four airborne or four urinary measurements. Reliability was moderately-high (weighted kappa range=0.60–0.64). Validity was poor to moderate (rs= -0.37–0.46) for both airborne and urinary concentrations of both metals. For airborne nickel concentrations, validity differed by plant. For dichotomized metrics, sensitivity and specificity were higher based on urinary measurements (47–78%) than airborne measurements (16–50%). Few patterns were observed by metal, assessment round, or expert type. These results suggest that, for electroplating exposures, experts can achieve moderately-high agreement and (reasonably) distinguish between low and high exposures when reviewing responses to in-depth questionnaires used in population-based case-control studies. PMID:24736099

  4. Monitoring of occupational exposure in manufacturing of stainless steel constructions. Part I: Chromium, iron, manganese, molybdenum, nickel and vanadium in the workplace air of stainless steel welders.

    PubMed

    Kucera, J; Bencko, V; Pápayová, A; Saligová, D; Tejral, J; Borská, L

    2001-11-01

    Exposure to workplace airborne pollutants was examined in a group of 20 workers dealing mainly with welding, polishing, drilling and assembling of stainless steel constructions. Airborne particulate matter (APM) collected using both personal and stationary samplers was analyzed by instrumental neutron activation analysis (INAA). Quality assurance procedures of both sampling and analytical stages are described. Of the elements determined, results are presented for chromium, iron, manganese, molybdenum, nickel and vanadium. The median values of element concentrations exceeded the maximum admissible limits for workplace pollutants only for chromium, while for nickel the limit was exceeded in several individual cases. Sampling of hair, nails, blood, urine and saliva to be used for biological monitoring of the exposed and control groups is also described.

  5. Chronic exposure to iron oxide, chromium oxide, and nickel oxide fumes of metal dressers in a steelworks

    PubMed Central

    Jones, J. Graham; Warner, C. G.

    1972-01-01

    Graham Jones, J., and Warner, C. G. (1972).Brit. J. industr. Med.,29, 169-177. Chronic exposure to iron oxide, chromium oxide, and nickel oxide fumes of metal dressers in a steelworks. Occupational and medical histories, smoking habits, respiratory symptoms, chest radiographs, and ventilatory capacities were studied in 14 steelworkers employed as deseamers of steel ingots for periods of up to 16 years. The men were exposed for approximately five hours of each working shift to fume concentrations ranging from 1·3 to 294·1 mg/m3 made up mainly of iron oxide with varying proportions of chromium oxide and nickel oxide. Four of the men, with 14 to 16 years' exposure, showed radiological evidence of pneumoconiosis classified as ILO categories 2 or 3. Of these, two had pulmonary function within the normal range and two had measurable loss of function, moderate in one case and mild in the other. Many observers would diagnose these cases as siderosis but the authors consider that this term should be reserved for cases exposed to pure iron compounds. The correct diagnosis is mixed-dust pneumoconiosis and the loss of pulmonary function is caused by the effects of the mixture of metallic oxides. It is probable that inhalation of pure iron oxide does not cause fibrotic pulmonary changes, whereas the inhalation of iron oxide plus certain other substances obviously does. Images PMID:5021996

  6. Lung cancer mortality in nickel/chromium platers, 1946-95.

    PubMed

    Sorahan, T; Burges, D C; Hamilton, L; Harrington, J M

    1998-04-01

    To investigate mortality from lung cancer in nickel/chromium platers. The mortality experience of a cohort of 1762 chrome workers (812 men, 950 women) from a large electroplating and light engineering plant in the Midlands, United Kingdom, was investigated for the period 1946-95. All subjects were first employed in chrome work at the plant during the period 1946-75, and had at least six months employment in jobs associated with exposure to chromic acid mist (hexavalent chromium). Detailed job histories were abstracted from original company personnel records and individual cumulative durations of employment in three types of chrome work were derived as time dependent variables (chrome bath work, other chrome work, any chrome work). Two analytical approaches were used--indirect standardisation and Poisson regression. Based on mortalities for the general population of England and Wales, male workers with some period of chrome bath work had higher lung cancer mortalities (observed deaths 40, expected deaths 25.41, standardised mortality ratio (SMR) 157, 95% confidence interval (95% CI) 113 to 214, p < 0.01) than did other male chrome workers (observed 9, expected 13.70, SMR 66, 95% CI 30 to 125). Similar findings were shown for female workers (chrome bath workers: observed 15, expected 8.57, SMR 175, 95% CI 98 to 289, p = 0.06; other chrome workers: observed 1, expected 4.37, SMR 23, 95% CI 1 to 127). Poisson regression was used to investigate risks of lung cancer relative to four categories of cumulative duration of chrome bath work and four categories of cumulative duration of other chrome work (none, < 1 y, 1-4 y, > or = 5 y). After adjusting for sex, age, calendar period, year of starting chrome work, period from first chrome work, and employment status (still employed v left employment), there was a significant positive trend (p < 0.05) between duration of chrome bath work and risks of mortality for lung cancer. Relative to a risk of unity for those chrome workers

  7. Hot corrosion of the B2 nickel aluminides

    NASA Technical Reports Server (NTRS)

    Ellis, David L.

    1993-01-01

    The hot corrosion behavior of the B2 nickel aluminides was studied to determine the inherent hot corrosion resistance of the beta nickel aluminides and to develop a mechanism for the hot corrosion of the beta nickel aluminides. The effects of the prior processing of the material, small additions of zirconium, stoichiometry of the materials, and preoxidation of the samples were also examined. Additions of 2, 5, and 15 w/o chromium were used to determine the effect of chromium on the hot corrosion of the beta nickel aluminides and the minimum amount of chromium necessary for good hot corrosion resistance. The results indicate that the beta nickel aluminides have inferior inherent hot corrosion resistance despite their excellent oxidation resistance. Prior processing and zirconium additions had no discernible effect on the hot corrosion resistance of the alloys. Preoxidation extended the incubation period of the alloys only a few hours and was not considered to be an effective means of stopping hot corrosion. Stoichiometry was a major factor in determining the hot corrosion resistance of the alloys with the higher aluminum alloys having a definitely superior hot corrosion resistance. The addition of chromium to the alloys stopped the hot corrosion attack in the alloys tested. From a variety of experimental results, a complex hot corrosion mechanism was proposed. During the early stages of the hot corrosion of these alloys the corrosion is dominated by a local sulphidation/oxidation form of attack. During the intermediate stages of the hot corrosion, the aluminum depletion at the surface leads to a change in the oxidation mechanism from a protective external alumina layer to a mixed nickel-aluminum spinel and nickel oxide that can occur both externally and internally. The material undergoes extensive cracking during the later portions of the hot corrosion.

  8. Effects of fixed orthodontic treatment using conventional versus metal-injection molding brackets on salivary nickel and chromium levels: a double-blind randomized clinical trial.

    PubMed

    Amini, Fariborz; Harandi, Saghar; Mollaei, Mobina; Rakhshan, Vahid

    2015-10-01

    Despite the importance of nickel and chromium release from orthodontic brackets, there are no in vivo or in vitro studies on this issue in the case of metal-injection molding (MIM) brackets. Saliva samples were collected from 30 orthodontic patients divided randomly into two groups of conventional and MIM brackets, before treatment and 2 months later. Approved attendees with odd and even numbers were, respectively, assigned to the control and treatment groups. For blinding, the patients were not informed of their bracket types, and the saliva samples were coded. Nickel and chromium levels were determined using atomic absorption spectrophotometry. Data were analysed using repeated-measures two-way analysis of covariance, independent-samples t-test, chi-squared, Spearman and point-biserial correlation coefficients, Mann-Whitney, and Wilcoxon tests (α = 0.05). Mean nickel level increased from 7.87±8.14 (pre-treatment) to 12.57±9.96 (2nd month) in the control group, and from 8.62±9.85 (pre-treatment) to 8.86±6.42 µg/l in the MIM group. Both of these increases were significant (Wilcoxon P < 0.03). Average chromium level changed from 0.25±0.56 (pre-treatment) to 0.35±0.62 and from 0.42±0.48 to 0.26±0.57 µg/l in the MIM group. Only the reduction observed in the MIM group was significant (Wilcoxon P = 0.0438). Age and gender had no significant influence on ion levels (P > 0.1). The differences between both ions' levels measured in the 60th day in both bracket groups were not significant (Mann-Whitney P > 0.05). The extents of changes over time were not significantly different between the bracket types (Mann-Whitney P > 0.05). The sample size was not predetermined based on power calculations. The spectrophotometer was limited to detecting chromium concentrations above 0.25 µg/l. Ion discharge from brackets might continuously change. The current in vivo methods are unable to take such fluctuations into account. Nickel might increase in patients undergoing

  9. Exposure to Nickel, Chromium, or Cadmium Causes Distinct Changes in the Gene Expression Patterns of a Rat Liver Derived Cell Line

    DTIC Science & Technology

    2011-11-16

    nickel, cadmium, and chromium are toxic industrial chemicals with an exposure. While these substances are known to produce adverse health effects leading...in both occupational and environmental settings that may cause harmful outcomes. While these substances are known to produce adverse health effects...that particular bin. A chi-squared test was used to test bin enrichment ( p ≤0.05). Probe sets that did not contain any biological process annotation were

  10. Comparative analysis of the fit of 3-unit implant-supported frameworks cast in nickel-chromium and cobalt-chromium alloys and commercially pure titanium after casting, laser welding, and simulated porcelain firings.

    PubMed

    Tiossi, Rodrigo; Rodrigues, Renata Cristina Silveira; de Mattos, Maria da Glória Chiarello; Ribeiro, Ricardo Faria

    2008-01-01

    This study compared the vertical misfit of 3-unit implant-supported nickel-chromium (Ni-Cr) and cobalt-chromium (Co-Cr) alloy and commercially pure titanium (cpTi) frameworks after casting as 1 piece, after sectioning and laser welding, and after simulated porcelain firings. The results on the tightened side showed no statistically significant differences. On the opposite side, statistically significant differences were found for Co-Cr alloy (118.64 microm [SD: 91.48] to 39.90 microm [SD: 27.13]) and cpTi (118.56 microm [51.35] to 27.87 microm [12.71]) when comparing 1-piece to laser-welded frameworks. With both sides tightened, only Co-Cr alloy showed statistically significant differences after laser welding. Ni-Cr alloy showed the lowest misfit values, though the differences were not statistically significantly different. Simulated porcelain firings revealed no significant differences.

  11. Corrosion-induced release of the main alloying constituents of manganese-chromium stainless steels in different media.

    PubMed

    Herting, Gunilla; Wallinder, Inger Odnevall; Leygraf, Christofer

    2008-09-01

    The main focus of this paper is the assessment of release rates of chromium, nickel, iron and manganese from manganese-chromium stainless steel grades of low nickel content. The manganese content varied between 9.7 and 1.5 wt% and the corresponding nickel content between 1 and 5 wt%. All grades were exposed to artificial rain and two were immersed in a synthetic body fluid of similar pH but of different composition and exposure conditions. Surface compositional studies were performed using X-ray photoelectron spectroscopy (XPS) in parallel to correlate the metal release process with changes in surface oxide properties. All grades, independent of media, revealed a time-dependent metal release process with a preferential low release of iron and manganese compared to nickel and chromium while the chromium content of the surface oxide increased slightly. Manganese was detected in the surface oxide of all grades, except the grade of the lowest manganese bulk content. No nickel was observed in the outermost surface oxide. Stainless steel grades of the lowest chromium content (approximately 16 wt%) and highest manganese content (approximately 7-9 wt%), released the highest quantity of alloy constituents in total, and vice versa. No correlation was observed between the release rate of manganese and the alloy composition. Released main alloy constituents were neither proportional to the bulk alloy composition nor to the surface oxide composition.

  12. Reducing chromium losses from a chromium plating bath. 1987 summer intern report. Project conducted at New Dimension Plating, Hutchinson, Minnesota

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Achman, D.

    1987-12-31

    The company employs about forty people and operates for one or two eight hour shifts with an average of 315 racks of chrome plating per eight hour day. They plate a variety of metals including copper, nickel, gold, brass and chromium. Chromium is the major metal plated and is usually the last step in plating cycle. Most parts are copper plated and then nickel plated in preparation for chrome plating. The main difference between New Dimension Plating and other plating shops is the variety of parts plated. As New Dimension Plating is a job shop, a wide range of partsmore » such as motorcycle accessories, stove parts, and custom items are metal finished. The plating lines are manual, meaning employees dip the racks into the tanks by hand. This fact along with the fact that parts vary greatly in size and shape accounts for the significant drag-out on the chromium plating line.« less

  13. NICKEL-BASE ALLOY

    DOEpatents

    Inouye, H.; Manly, W.D.; Roche, T.K.

    1960-01-19

    A nickel-base alloy was developed which is particularly useful for the containment of molten fluoride salts in reactors. The alloy is resistant to both salt corrosion and oxidation and may be used at temperatures as high as 1800 deg F. Basically, the alloy consists of 15 to 22 wt.% molybdenum, a small amount of carbon, and 6 to 8 wt.% chromium, the balance being nickel. Up to 4 wt.% of tungsten, tantalum, vanadium, or niobium may be added to strengthen the alloy.

  14. 4-META opaque resin--a new resin strongly adhesive to nickel-chromium alloy.

    PubMed

    Tanaka, T; Nagata, K; Takeyama, M; Atsuta, M; Nakabayashi, N; Masuhara, E

    1981-09-01

    1) A new adhesive opaque resin containing a reactive monomer, 4-methacryloxy-ethyl trimellitate anhydride (4-META), was prepared, and its application to thermosetting acrylic resin veneer crowns was studied. 2) The 4-META opaque resin was applied to a variety of nickel-chromium dental alloy specimens which had undergone different treatment, and endurance tests were conducted to evaluate the durability of adhesion. 3) Stable adhesion against water penetration was achieved with metal surfaces first etched with HCl and then oxidized with HNO3. A bond strength of 250 kg/cm2 was maintained even after immersion in water at 37 degrees C for 30 wk or at 80 degrees C for ten wk. Furthermore, this value did not decrease even after the specimens were subjected to 500 thermal cycles. 4) The 4-META opaque resin studied can eliminate the necessity for retention devices on metal castings. 5) The smooth 4-META opaque resin should have no adverse effects on gingivae.

  15. The release of nickel and other trace elements from electric kettles and coffee machines.

    PubMed

    Berg, T; Petersen, A; Pedersen, G A; Petersen, J; Madsen, C

    2000-03-01

    The release of nickel, chromium and lead from electric kettles to water under conditions simulating regular household use was investigated. Ten out of 26 kettles sold on the Danish market released more than 50 micrograms/l nickel to water, whereas neither lead nor chromium was released in any significant amount. Fifty micrograms/l of nickel in water was chosen as the threshold of action, because concentrations below this value were considered unlikely to provide outbreaks of eczema for those consumers suffering from contact allergy to nickel, who are also sensitive to the content of nickel in the diet. This first part of the study was followed up by a dialogue between the kettle producers and the Danish authorities, leading to a change of construction or design for those kettles that did not comply with the criteria. As a follow-up study another ten kettles were studied to check whether compliance was improved. Two of these ten kettles still released more than 50 micrograms/l nickel to water under the test conditions. These two kettles, however, were subsequently withdrawn from the market. Coffee machines tested similarly did not release aluminium, lead, chromium or nickel in quantities of any significance.

  16. Nickel, chromium and cobalt: the relevant allergens in allergic contact dermatitis. Comparative study between two periods: 1995-2002 and 2003-2015*

    PubMed Central

    Duarte, Ida; Mendonça, Rodolfo Ferreira; Korkes, Karen Levy; Lazzarini, Rosana; Hafner, Mariana de Figueiredo Silva

    2018-01-01

    Background Metals are common agents of allergic contact dermatitis, occupational or not, with decreasing incidence over the last years in some countries that have regulated the amount of nickel in objects. Objectives To analyze and compare with previous studies the profile of metal sensitization between 2003-2015. Methods Patients who underwent patch testing between 2003-2015 were evaluated retrospectively regarding the sensitization rates to metals, the associations between them, the relationship with profession and epidemiology. Results Of the 1,386 patients tested, 438 (32%) had positive test to some metal, similar results to the 404/1,208 (33%) of the previous study (1995-2002) performed at the same service (p=0.32). The frequency of nickel (77%), cobalt (32%) and chromium (29%) changed slightly (p=0.20). Most cases of sensitization to chromium were related to the occupation (64%), in contrast to nickel and cobalt (p<0.0001). There was a predominance of females among those sensitized to metal in both studies (p=0.63) and the age group of 20-49 years old (p=0.11); the number of fair-skinned individuals increased (p<0.001), as well as the lesions in the cephalic segment (50.5%; p<0.0001) and hands (45%; p<0.0001), which are not the most frequent location anymore. The number of cleaners decreased (39% vs. 59%; p<0.0001), which still lead in front of bricklayers/painters, which increased (14% vs. 9%; p=0.013). The frequency of wet work reduced (65% vs. 81%; p<0.0001). Study limitations The study included a single population group; only patients with positive tests to metals were considered - the others were not evaluated for the possibility of false negatives. Conclusion The sensitization to metals, occupational or not, has been significant over the last 21 years, with few epidemiological changes. PMID:29641698

  17. Nickel, chromium and cobalt: the relevant allergens in allergic contact dermatitis. Comparative study between two periods: 1995-2002 and 2003-2015.

    PubMed

    Duarte, Ida; Mendonça, Rodolfo Ferreira; Korkes, Karen Levy; Lazzarini, Rosana; Hafner, Mariana de Figueiredo Silva

    2018-01-01

    Metals are common agents of allergic contact dermatitis, occupational or not, with decreasing incidence over the last years in some countries that have regulated the amount of nickel in objects. To analyze and compare with previous studies the profile of metal sensitization between 2003-2015. Patients who underwent patch testing between 2003-2015 were evaluated retrospectively regarding the sensitization rates to metals, the associations between them, the relationship with profession and epidemiology. Of the 1,386 patients tested, 438 (32%) had positive test to some metal, similar results to the 404/1,208 (33%) of the previous study (1995-2002) performed at the same service (p=0.32). The frequency of nickel (77%), cobalt (32%) and chromium (29%) changed slightly (p=0.20). Most cases of sensitization to chromium were related to the occupation (64%), in contrast to nickel and cobalt (p<0.0001). There was a predominance of females among those sensitized to metal in both studies (p=0.63) and the age group of 20-49 years old (p=0.11); the number of fair-skinned individuals increased (p<0.001), as well as the lesions in the cephalic segment (50.5%; p<0.0001) and hands (45%; p<0.0001), which are not the most frequent location anymore. The number of cleaners decreased (39% vs. 59%; p<0.0001), which still lead in front of bricklayers/painters, which increased (14% vs. 9%; p=0.013). The frequency of wet work reduced (65% vs. 81%; p<0.0001). The study included a single population group; only patients with positive tests to metals were considered - the others were not evaluated for the possibility of false negatives. The sensitization to metals, occupational or not, has been significant over the last 21 years, with few epidemiological changes.

  18. Aluminide coatings for nickel base alloys

    NASA Technical Reports Server (NTRS)

    Fiedler, H. C.; Sieraski, R. J.

    1971-01-01

    The metalliding process was used to aluminide IN-100 and TD NiCr. Aluminum was deposited over a broad range of deposition rates, with two types of coating structures resulting. Chromium, silicon, titanium and yttrium were also individually deposited simutaneously with aluminum on IN-100. None of these had a marked effect on the oxidation resistance of the aluminide coating. Porosity-free aluminide coatings with good oxidation resistance were formed on TD NiCr providing the aluminum concentration did not exceed 8 percent, the limit of solubility in the gamma phase.

  19. Experimental patch testing with chromium-coated materials.

    PubMed

    Bregnbak, David; Thyssen, Jacob P; Jellesen, Morten S; Zachariae, Claus; Johansen, Jeanne D

    2017-06-01

    Chromium coatings on metal alloys can be decorative, and prevent corrosion and metal ion release. We recently showed that handling of a chromium-containing disc resulted in chromium deposition on the skin. To examine patch test reactivity to chromium-coated discs. We included 15 patients: 10 chromium-allergic patients, and 5 patients without chromium allergy. All were patch tested with potassium dichromate, cobalt chloride, nickel sulfate, and nine different metallic discs. The chromium-allergic patients were also patch tested with serial dilutions of potassium dichromate. Positive/weaker reactions were observed to disc B (1 of 10), disc C (1 of 10), and disc D, disc E, and disc I (4 of 10 each). As no controls reacted to any of the discs, the weak reactions indicate allergic reactions. Positive patch test reactions to 1770 ppm chromium(VI) in the serial dilutions of potassium dichromate were observed in 7 of 10 patients. When the case group was narrowed down to include only the patients with a current positive patch test reaction to potassium dichromate, elicitation of dermatitis by both chromium(III) and chromium(VI) discs was observed in 4 of 7 of patients. Many of the patients reacted to both chromium(III) and chromium(VI) surfaces. Our results indicate that both chromium(VI) and chromium(III) pose a risk to chromium-allergic patients. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Hot corrosion of four superalloys - HA-188, S-57, IN-617, and TD-NiCrAl

    NASA Technical Reports Server (NTRS)

    Santoro, G. J.

    1979-01-01

    Cyclic oxidation and hot corrosion tests of two cobalt-base and two nickel-base alloys are reported. The alloys were exposed to maximum temperatures of 900 and 1000 C in a Mach 0.3 burner rig whose flame was doped with various concentrations of sea salt and sodium sulfate for hot corrosion tests. The test data were subjected to a regression analysis for the development of model equations relating corrosion to temperature and for the effects of salt concentration and composition on corrosion. The corrosion resistance varied with temperature, sea salt concentration, and salt composition, concluding that the S-57 cobalt-base alloy was the most hot corrosion-resistant alloy, and the TD-NiCrAl nickel-base alloy was the least resistant. However, under straight oxidation conditions, the TD-NiCrAl was most resistant, while S-57 was the least resistant alloy.

  1. [Metallurgical differentiation of cobalt-chromium alloys for implants].

    PubMed

    Holzwarth, U; Thomas, P; Kachler, W; Göske, J; Schuh, A

    2005-10-01

    Cobalt Chromium alloys are used in cemented total hip or knee arthroplasty as well as in metal-on-metal bearings in total hip arthroplasty. An increasing number of publications report about (allergic) reactions to wear particles of Cobalt Chromium alloys. Reactions to nickel are more frequent in comparison to Cobalt or Chromium particles. It is well known that different kinds of Cobalt Chromium alloys contain different amounts of alloying elements; nevertheless. The aim of the current work was to compare the different Cobalt Chromium alloys according to ASTM F or ISO standards in respect to the different alloying elements. Co28Cr6Mo casting alloys according to ASTM F 75 or ISO 5832-4 as well as forging alloy types according to ASTM F 799 and ISO 5832 such as Co20Cr15W10Ni, Co35Ni20Cr, Fe40Co20Cr10Ni, Co20Cr20Ni, and Co28Cr6Mo were analyzed in respect to their element content of Co, Cr, Ni, Mo, Fe, W, and Mn. In 1935 the Cobalt based alloy "Vitallium" Co30Cr5Mo basically used in the aircraft industry was introduced into medicine. The chemical composition of this alloy based on Cobalt showed 30 wt.% Chromium and 5 wt.% Molybdenum. The differentiation using alloy names showed no Nickel information in single alloy names. The information given about different alloys can lead to an unprecise evaluation of histopathological findings in respect to alloys or alloying constituents. Therefore, implant manufacturers should give the exact information about the alloys used and adhere to European law, Euronorm 93/42/EWG.

  2. Concentrations of the Genotoxic Metals, Chromium and Nickel, in Whales, Tar Balls, Oil Slicks, and Released Oil from the Gulf of Mexico in the Immediate Aftermath of the Deepwater Horizon Oil Crisis: Is Genotoxic Metal Exposure Part of the Deepwater Horizon Legacy?

    PubMed Central

    2015-01-01

    Concern regarding the Deepwater Horizon oil crisis has largely focused on oil and dispersants while the threat of genotoxic metals in the oil has gone largely overlooked. Genotoxic metals, such as chromium and nickel, damage DNA and bioaccumulate in organisms, resulting in persistent exposures. We found chromium and nickel concentrations ranged from 0.24 to 8.46 ppm in crude oil from the riser, oil from slicks on surface waters and tar balls from Gulf of Mexico beaches. We found nickel concentrations ranged from 1.7 to 94.6 ppm wet weight with a mean of 15.9 ± 3.5 ppm and chromium concentrations ranged from 2.0 to 73.6 ppm wet weight with a mean of 12.8 ± 2.6 ppm in tissue collected from Gulf of Mexico whales in the wake of the crisis. Mean tissue concentrations were significantly higher than those found in whales collected around the world prior to the spill. Given the capacity of these metals to damage DNA, their presence in the oil, and their elevated concentrations in whales, we suggest that metal exposure is an important understudied concern for the Deepwater Horizon oil disaster. PMID:24552566

  3. Concentrations of the genotoxic metals, chromium and nickel, in whales, tar balls, oil slicks, and released oil from the gulf of Mexico in the immediate aftermath of the deepwater horizon oil crisis: is genotoxic metal exposure part of the deepwater horizon legacy?

    PubMed

    Wise, John Pierce; Wise, James T F; Wise, Catherine F; Wise, Sandra S; Gianios, Christy; Xie, Hong; Thompson, W Douglas; Perkins, Christopher; Falank, Carolyne; Wise, John Pierce

    2014-01-01

    Concern regarding the Deepwater Horizon oil crisis has largely focused on oil and dispersants while the threat of genotoxic metals in the oil has gone largely overlooked. Genotoxic metals, such as chromium and nickel, damage DNA and bioaccumulate in organisms, resulting in persistent exposures. We found chromium and nickel concentrations ranged from 0.24 to 8.46 ppm in crude oil from the riser, oil from slicks on surface waters and tar balls from Gulf of Mexico beaches. We found nickel concentrations ranged from 1.7 to 94.6 ppm wet weight with a mean of 15.9 ± 3.5 ppm and chromium concentrations ranged from 2.0 to 73.6 ppm wet weight with a mean of 12.8 ± 2.6 ppm in tissue collected from Gulf of Mexico whales in the wake of the crisis. Mean tissue concentrations were significantly higher than those found in whales collected around the world prior to the spill. Given the capacity of these metals to damage DNA, their presence in the oil, and their elevated concentrations in whales, we suggest that metal exposure is an important understudied concern for the Deepwater Horizon oil disaster.

  4. Chromium(VI) release from leather and metals can be detected with a diphenylcarbazide spot test.

    PubMed

    Bregnbak, David; Johansen, Jeanne D; Jellesen, Morten S; Zachariae, Claus; Thyssen, Jacob P

    2015-11-01

    Along with chromium, nickel and cobalt are the clinically most important metal allergens. However, unlike for nickel and cobalt, there is no validated colorimetric spot test that detects chromium. Such a test could help both clinicians and their patients with chromium dermatitis to identify culprit exposures. To evaluate the use of diphenylcarbazide (DPC) as a spot test reagent for the identification of chromium(VI) release. A colorimetric chromium(VI) spot test based on DPC was prepared and used on different items from small market surveys. The DPC spot test was able to identify chromium(VI) release at 0.5 ppm without interference from other pure metals, alloys, or leather. A market survey using the test showed no chromium(VI) release from work tools (0/100). However, chromium(VI) release from metal screws (7/60), one earring (1/50), leather shoes (4/100) and leather gloves (6/11) was observed. We found no false-positive test reactions. Confirmatory testing was performed with X-ray fluorescence (XRF) and spectrophotometrically on extraction fluids. The use of DPC as a colorimetric spot test reagent appears to be a good and valid test method for detecting the release of chromium(VI) ions from leather and metal articles. The spot test has the potential to become a valuable screening tool. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Nickel and associated metals in New Caledonia: Exposure levels and their determinants.

    PubMed

    St-Jean, Audray; Barguil, Yann; Dominique, Yannick; Le Bot, Barbara; Ayotte, Pierre; Cordier, Sylvaine

    2018-06-01

    The ultramafic massifs of the New Caledonian archipelago contain about 10% of the world's nickel reserves, which also contain significant but lower amounts of cobalt, chromium, and manganese. Natural erosion of these massifs and mining activities may contribute to the exposure of local populations to these metals through contamination of air, food, and water resources. We conducted a biomonitoring survey to evaluate exposure to these four metals and its main determinants by constructing a stratified sample of 732 adults and children (>3 years old) from visitors to 22 health centers across the archipelago. Urine was collected and analyzed by inductively-coupled plasma mass spectrometry to determine metal concentrations. A face-to-face interview was conducted to document sociodemographic characteristics, lifestyle and dietary habits, and residence-mine distance. Environmental samples (soil, house dust, water, and foodstuffs) were collected from two areas (one with and one without mining activity) to delineate determinants of exposure in more detail. Nickel and chromium were metals with the highest concentrations found in urine, especially in children, at levels exceeding reference values derived from representative national surveys elsewhere throughout the world (for children: 4.7 μg/g creatinine for nickel and 0.50 μg/g creatinine for chromium): 13% of children exceeded the reference value for nickel and 90% for chromium. Large variations were observed by region, age, and sex. In this geological setting, urinary and environmental nickel concentrations appear to be driven mainly by soil content. This is the first archipelago-wide survey of metal exposure in New Caledonia. The potential health consequences of this chronic high exposure need to be assessed. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Nickel speciation in several serpentine (ultramafic) topsoils via bulk synchrotron-based techniques

    USDA-ARS?s Scientific Manuscript database

    Serpentine soils are extensively studied because of their unique soil chemical properties and flora. They commonly have high magnesium-to-calcium ratios and elevated concentrations of trace metals including nickel, cobalt, and chromium. Several nickel hyperaccumulator plants are native to serpenti...

  7. Selective rear side ablation of thin nickel-chromium-alloy films using ultrashort laser pulses

    NASA Astrophysics Data System (ADS)

    Pabst, Linda; Ullmann, Frank; Ebert, Robby; Exner, Horst

    2018-03-01

    In recent years, the selective laser structuring from the transparent substrate side plays an increased role in thin film processing. The rear side ablation is a highly effective ablation method for thin film structuring and revels a high structuring quality. Therefore, the rear side ablation of nickel-chromium-alloy thin films on glass substrate was investigated using femtosecond laser irradiation. Single and multiple pulses ablation thresholds as well as the incubation coefficient were determined. By irradiation from the transparent substrate side at low fluences a cracking or a partly delamination of the film could be observed. By increasing the fluence the most part of the film was ablated, however, a very thin film remained at the interface of the glass substrate. This thin remaining layer could be completely ablated by two pulses. A further increase of the pulse number had no influence on the ablation morphology. The ablated film was still intact and an entire disc or fragments could be collected near the ablation area. The fragments showed no morphology change and were still in solid state.

  8. A study of reduced chromium content in a nickel-base superalloy via element substitution and rapid solidification processing. Ph.D. ThesisFinal Report

    NASA Technical Reports Server (NTRS)

    Powers, William O.

    1987-01-01

    A study of reduced chromium content in a nickel base superalloy via element substitution and rapid solidification processing was performed. The two elements used as partial substitutes for chromium were Si and Zr. The microstructure of conventionally solidified materials was characterized using microscopy techniques. These alloys were rapidly solidified using the chill block melt spinning technique and the rapidly solidified microstructures were characterized using electron microscopy. The spinning technique and the rapidly solidified microstructures was assessed following heat treatments at 1033 and 1272 K. Rapidly solidified material of three alloys was reduced to particulate form and consolidated using hot isostatic pressing (HIP). The consolidated materials were also characterized using microscopy techniques. In order to evaluate the relative strengths of the consolidated alloys, compression tests were performed at room temperature and 1033 K on samples of as-HIPed and HIPed plus solution treated material. Yield strength, porosity, and oxidation resistance characteristics are given and compared.

  9. Nickel and chromium levels in the saliva of a Saudi sample treated with fixed orthodontic appliances.

    PubMed

    Talic, Nabeel F; Alnahwi, Hasan H; Al-Faraj, Ali S

    2013-10-01

    The aim of this study was to measure the amount of nickel (Ni) and chromium (Cr) released into the saliva of Saudi patients treated with fixed orthodontic appliances. Ninety salivary samples were collected in a cross-sectional manner. Forty samples were collected from patients (17 males, 23 females) with fixed orthodontic appliances after different periods of orthodontic treatment ranging from the first month and up to 32 months into treatment. The fixed orthodontic appliance consisted of 4 bands, 20 stainless steel brackets, and upper and lower nickel titanium or stainless-steel arch wires. The other 50 samples were collected from people without appliances (24 males, 26 females). Samples were analyzed using Inductive Coupled Plasma/Mass Spectrometry and Inductively Coupled Plasma Optical Emission Spectroscopy to measure Ni and Cr levels, respectively. Student's t-test was used to compare Ni and Cr levels in the treated and untreated control groups. The mean Ni level was 4.197 μg/L in the experimental group and 2.3 μg/L in the control group (p < 0.05). The mean Cr level was 2.9 μg/L in the experimental group and 3.3 μg/L in the control group (p < 0.05). Fixed orthodontic appliances resulted in a non-toxic increase in salivary levels of Ni, but no change in Cr levels. Duration of orthodontic treatment did not affect Ni and Cr levels in the saliva.

  10. Sources, transport and alterations of metal compounds: an overview. I. Arsenic, beryllium, cadmium, chromium, and nickel.

    PubMed Central

    Fishbein, L

    1981-01-01

    An overview is presented of the current state of knowledge of the salient aspects of the sources, transport, and alterations of arsenic, beryllium, cadmium, chromium, and nickel. This information is considered vital for a better assessment of the scope of potential human hazard to these ubiquitous toxicants and their compounds. Stress is focused on both natural and industrial activities, particularly on the latter's projected trends. Increasing use patterns per se of most of these metals, as well as aspects of waste disposal and the anticipated increased combustion of fossil fuels for power generation and space heating (particularly in the United States), are major causes of potential health concern. Additionally, attention is drawn to the need for increased research to fill the gaps in our knowledge in these vital areas, all in the hope of permitting a more facile identification and quantification of the potential hazard to exposure to these agents. PMID:7023934

  11. Welding of high chromium steels

    NASA Technical Reports Server (NTRS)

    Miller, W B

    1928-01-01

    A brief description is given of different groups of high chromium steels (rustless iron and stainless steels) according to their composition and more generally accepted names. The welding procedure for a given group will be much the same regardless of the slight variations in chemical composition which may exist within a certain group. Information is given for the tensile properties (yield point and ultimate strength) of metal sheets and welds before and after annealing on coupons one and one-half inches wide. Since welds in rustless iron containing 16 to 18 percent chromium and 7 to 12 percent nickel show the best combination of strength and ductility in the 'as welded' or annealed condition, it is considered the best alloy to use for welded construction.

  12. Solid state welding processes for an oxide dispersion strengthened nickel-chromium-aluminum alloy

    NASA Technical Reports Server (NTRS)

    Moore, T. J.

    1975-01-01

    Solid-state welding processes were evaluated for joining TD-NiCrAl (Ni-16Cr-4Al-2ThO2) alloy sheet. Both hot-press and resistance spot welding techniques were successfully applied in terms of achieving grain growth across the bond line. Less success was achieved with a resistance seam welding process. In stress-rupture shear and tensile shear tests of lap joints at 1100 C, most failures occurred in the parent material, which indicates that the weld quality was good and that the welds were not a plane of weakness. The overall weld quality was not as good as previously attained with TD-NiCr, probably because the presence of alumina at the faying surfaces and the developmental TD-NiCrAl sheet, which was not of the quality of the TD-NiCr sheet in terms of surface flatness and dimensional control.

  13. Estimation of changes in nickel and chromium content in nickel-titanium and stainless steel orthodontic wires used during orthodontic treatment: An analytical and scanning electron microscopic study.

    PubMed

    Kararia, Vandana; Jain, Pradeep; Chaudhary, Seema; Kararia, Nitin

    2015-01-01

    The biocompatibility of orthodontic dental alloys has been investigated over the past 20 years, but the results have been inconclusive. The study compares standard 3 M Unitek nickel-titanium (NiTi) and stainless steel archwires with locally available JJ orthodontics wires. Scanning electron microscope (SEM) study of surface changes and complexometric titration to study compositional change was performed. Ten archwires each of group 1-3 M 0.016" NiTi, group 2-JJ 0.016" NiTi, group 3-3 M 0.019" *0.025" SS and group 4-JJ SS contributed a 10 mm piece of wire for analysis prior to insertion in the patient and 6 weeks post insertion. SEM images were recorded at ×2000, ×4000 and ×6000 magnification. The same samples were subjected to complexiometric titration using ethylenediaminetetraacetic acid to gauge the actual change in the composition. The SEM images of all the archwires showed marked changes with deep scratches and grooves and dark pitting corrosion areas post intraoral use. 3M wires showed an uniform criss-cross pattern in as received wires indicating a coating which was absent after intraoral use. There was a significant release of Nickel and Chromium from both group 3 and 4. Group 2 wires released ions significantly more than group 1 (P = 0.0). Extensive and stringent trials are required before certifying any product to be used in Orthodontics.

  14. Development of Protective Coatings for Chromium-Base Alloys

    NASA Technical Reports Server (NTRS)

    English, J. J.; MacMillan, C. A.; Williams, D. N.; Bartlett, E. S.

    1966-01-01

    Chromium alloy sheet was clad with 5 to 10-mil-thick oxidation-resistant nickel-base alloy foils. Specimens also contained 1/2 to 1-mil-thick intermediate layers of platinum, tungsten, and/or W-25Re. Cladding was done by the isostatic hot gas-pressure bonding,.process. The clad chromium-alloy specimens were cyclic oxidation tested at 2100 F and 2300 F for up to 200 hours to determine the effectiveness of these metal claddings in protecting the chromium alloy Cr-5W from oxidation and contamination. Cladding systems consisting of 5-mil-thick Ni-20Cr-20W modified with 3 to 5 weight percent aluminum and containing a 1 /2-mil tungsten diffusion barrier demonstrated potential for long-time service at temperatures as high as 2300 F.

  15. Estimation of changes in nickel and chromium content in nickel-titanium and stainless steel orthodontic wires used during orthodontic treatment: An analytical and scanning electron microscopic study

    PubMed Central

    Kararia, Vandana; Jain, Pradeep; Chaudhary, Seema; Kararia, Nitin

    2015-01-01

    Introduction: The biocompatibility of orthodontic dental alloys has been investigated over the past 20 years, but the results have been inconclusive. The study compares standard 3 M Unitek nickel-titanium (NiTi) and stainless steel archwires with locally available JJ orthodontics wires. Scanning electron microscope (SEM) study of surface changes and complexometric titration to study compositional change was performed. Materials and Methods: Ten archwires each of group 1–3 M 0.016” NiTi, group 2-JJ 0.016” NiTi, group 3–3 M 0.019” *0.025” SS and group 4-JJ SS contributed a 10 mm piece of wire for analysis prior to insertion in the patient and 6 weeks post insertion. SEM images were recorded at ×2000, ×4000 and ×6000 magnification. The same samples were subjected to complexiometric titration using ethylenediaminetetraacetic acid to gauge the actual change in the composition. Observations and Results: The SEM images of all the archwires showed marked changes with deep scratches and grooves and dark pitting corrosion areas post intraoral use. 3M wires showed an uniform criss-cross pattern in as received wires indicating a coating which was absent after intraoral use. There was a significant release of Nickel and Chromium from both group 3 and 4. Group 2 wires released ions significantly more than group 1 (P = 0.0). Conclusion: Extensive and stringent trials are required before certifying any product to be used in Orthodontics. PMID:25684911

  16. Correlations between mechanical properties and cavitation erosion resistance for stainless steels with 12% Chromium and variable contents of Nickel

    NASA Astrophysics Data System (ADS)

    Bordeasu, I.; Popoviciu, M. O.; Mitelea, I.; Ghiban, B.; Ghiban, N.; Sava, M.; Duma, S. T.; Badarau, R.

    2014-03-01

    The running time of hydraulic machineries in cavitation conditions, especially blades and runners, depend on both chemical composition and mechanical properties of the used steels. The researches of the present paper have as goal to obtain new materials with improved behavior and reduced costs. There are given cavitation erosion results upon eight cast steels with martensite as principal structural constituent. The chromium content was maintained constant at approximate 12% but the nickel content was largely modified. The change of chemical content resulted in various proportions of austenite, martensite and ferrite and also in different cavitation erosion behavior. From the eight tested steels four have greater carbon content (approximately 0.1%) and the other four less carbon content (approximate 0.036%). All steels were tested separately in two laboratory facilities: T1 with magnetostrictive nickel tube (vibration amplitude 94 μm, vibration frequency 7000 ± 3% Hz, specimen diameter 14 mm and generator power 500 W) and T2 is respecting the ASTM G32-2010 Standard (vibration amplitude 50μm, vibration frequency 20000 ± 1% Hz, specimen diameter 15.8 mm and generator power 500 W). Analyzing the results it can be seen that the cavitation erosion is correlated with the mechanical properties in the way shown in 1960 by Hammitt and Garcia but is influenced by the structural constituents.

  17. Assessment of nickel release from various dental appliances used routinely in pediatric dentistry.

    PubMed

    Kulkarni, Parimala; Agrawal, Suchi; Bansal, Arpana; Jain, Ankur; Tiwari, Utkarsh; Anand, Ayushi

    2016-01-01

    The use of nickel-containing alloys in dentistry has been questioned because of the biological liabilities of nickel and the release of nickel ions from dental appliances into the oral cavity. The potential health hazards of nickel and chromium and their compounds have been the focus of attention for more than 100 years. It has established that these metals could cause hypersensitivity. To assess the nickel release from various dental appliances used in pediatric dentistry. It is a in vitro study. The study was undertaken to analyze in vitro biodegradation of space maintainers and stainless steel crowns made out of stainless steel materials from different manufacturers. The leaching effect simulating the use of clinical practice was studied by keeping the respective number of Stainless Steel Crowns and space maintainers in the artificial saliva incubating at 37°C and analyzing for nickel release after 1,7,14,21 and 28 days using atomic absorption spectrophotometer. The results were statistically analyzed by using One way ANOVA and repeated measures of ANOVA was applied at different time intervals i.e. 1,7,14,21,28 days. The critical value for statistical significance was set at P = 0.05. Results showed that there was measurable release of nickel which reached maximum level at the end of 7 days which was statistically significant (P < 0.05). The release of nickel and chromium very much below when compared with the average dietary intake of nickel (200-300 ppm/day) which were not capable of causing any toxic effects.

  18. Nickel aluminide alloy for high temperature structural use

    DOEpatents

    Liu, Chain T.; Sikka, Vinod K.

    1991-01-01

    The specification discloses nickel aluminide alloys including nickel, aluminum, chromium, zirconium and boron wherein the concentration of zirconium is maintained in the range of from about 0.05 to about 0.35 atomic percent to improve the ductility, strength and fabricability of the alloys at 1200.degree. C. Titanium may be added in an amount equal to about 0.2 to about 0.5 atomic percent to improve the mechanical properties of the alloys and the addition of a small amount of carbon further improves hot fabricability.

  19. Cytokine detection for the diagnosis of chromium allergy*

    PubMed Central

    Martins, Luis Eduardo Agner Machado; dos Reis, Vitor Manoel Silva

    2013-01-01

    BACKGROUND Patch testing remains the gold standard method for the identification of the etiologic agent of allergic contact dermatitis. However, it is a subjective, time-consuming exam whose technique demands special care and which presents some contraindications, which hamper its use. In a recent study, we showed that the proliferation assay can suitably replace patch testing for the diagnosis of chromium allergy, which had been previously demonstrated only for nickel allergy. In this study, we try to refine the method by reducing the incubation period of cultures for lymphocyte proliferation assays in response to chromium. OBJECTIVE Develop an alternative or complementary diagnostic test for chromium allergic contact dermatitis. METHODS We compared the production of 9 cytokines (IFN-γ, IL-2, IL-4, IL-5, IL-10, IL-12, IL-13, IL-17 and RANTES) between 18 chromium-allergic patients and 19 controls. RESULTS Chromium increased the production of IFN-y, IL-5, IL-2 and IL-13 in allergic patients, but only IL-2 and especially IL-13 helped discriminate allergic patients from controls. The sensitivity, specificity and accuracy found with IL-13 were about 80%. CONCLUSIONS IL-13 and IL-2 detection may be used to diagnose chromium allergy in 2-day cultures. However, in general, the 6-day cultures seem to be superior for this purpose. PMID:24173176

  20. High weldability nickel-base superalloy

    DOEpatents

    Gibson, Robert C.; Korenko, Michael K.

    1980-01-01

    This is a nickel-base superalloy with excellent weldability and high strength. Its composition consists essentially of, by weight percent, 10-20 iron, 57-63 nickel, 7-18 chromium, 4-6 molybdenum, 1-2 niobium, 0.2-0.8 silicon, 0.01-0.05 zirconium, 1.0-2.5 titanium, 1.0-2.5 aluminum, 0.02-0.06 carbon, and 0.002-0.015 boron. The weldability and strength of this alloy give it a variety of applications. The long-time structural stability of this alloy together with its low swelling under nuclear radiation conditions, make it especially suitable for use as a duct material and controlling element cladding for sodium-cooled nuclear reactors.

  1. Influence of melting and casting methods and finish line design on the marginal discrepancy of nickel-chromium-titanium alloy crowns.

    PubMed

    Cogolludo, Pablo G; Suarez, María J; Peláez, Jesús; Lozano, José F L

    2010-01-01

    The aim of this study was to analyze the influence of melting and casting procedures and the cervical finish line design on the marginal fit of nickel-chromium-titanium alloy crowns. Sixty standardized specimens were prepared to receive metal-ceramic crowns and were divided into two groups according to the cervical finish line: chamfer or rounded shoulder. Three melting and casting procedures were analyzed: (1) induction-centrifuge (IC), (2) gas oxygen torch-centrifuge (TC), and (3) induction-vacuum/pressure (IP). The marginal fit was measured with an image analysis system. Significant differences (P =.005) were observed among the groups, with TC showing the lowest discrepancies (45.87 μm). No significant differences were observed between the two finish lines. The accuracy of fit achieved for the groups analyzed may be regarded as within the range of clinical acceptance.

  2. Gamma prime hardened nickel-iron based superalloy

    DOEpatents

    Korenko, Michael K.

    1978-01-01

    A low swelling, gamma prime hardened nickel-iron base superalloy useful for fast reactor duct and cladding applications is described having from about 7.0 to about 10.5 weight percent (wt%) chromium, from about 24 to about 35 wt% nickel, from about 1.7 to about 2.5 wt% titanium, from about 0.3 to about 1.0 wt% aluminum, from about 2.0 to about 3.3 wt% molybdenum, from about 0.05 to about 1.0 wt% silicon, from about 0.03 to about 0.06 wt% carbon, a maximum of about 2 wt% manganese, and the balance iron.

  3. Patch test reactivity to a cobalt-chromium-molybdenum alloy and stainless steel in metal-allergic patients in correlation to the metal ion release.

    PubMed

    Summer, Burkhard; Fink, Ulrich; Zeller, Richard; Rueff, Franziska; Maier, Sonja; Roider, Gabriele; Thomas, Peter

    2007-07-01

    Nickel, chromium, and cobalt released from stainless steel and CoCrMo alloys have been postulated to trigger hypersensitivity reactions. The objective of this study was to assess the ion release from a CoCrMo alloy and stainless steel in vitro and the cutaneous reactivity to it by patch test. 52 metal-allergic patients and 48 non-allergic controls were patch tested to stainless steel and CoCrMo discs. In addition, using atomic absorption spectrometry, the release of nickel, cobalt, and chromium from both materials was assessed upon 2-day exposure to distilled water, artificial sweat (AS), and cell culture medium. There was low nickel ion release from stainless steel (0.3-0.46 microg/cm(2)/2 days) and CoCrMo discs (up to 0.33 microg/cm(2)/2 days) into the different elution media. Chromium release from the 2 materials was also very low (0.06-0.38 microg/cm(2)/2 days from stainless steel and 0.52-1.36 microg/cm(2)/2 days from CoCrMo alloy). In contrast, AS led to abundant cobalt release (maximally 18.94 microg/cm(2)/2 days) from the CoCrMo discs, with concomitant eczematous reaction upon patch testing: 0 of the 52 metal-allergic patients reacted to stainless steel discs and 5 of the 52 patients to CoCrMo discs (all 5 patients were cobalt allergic and 3 also nickel and chromium allergic). None of the controls reacted to the discs. Apart from nickel being a focus of allergological research, our results point to the possibly underestimated association of cobalt release and potential hyperreactivity to CoCrMo alloy.

  4. The influence of aliovalent impurities on the oxidation kinetics of nickel at high temperatures

    NASA Astrophysics Data System (ADS)

    Mrowec, S.; Grzesik, Z.; Rajchel, B.; Gil, A.; Dabek, J.

    2005-01-01

    The influence of chromium and sodium on the nickel oxidation kinetics has been studied as a function of temperature (1373-1673 K) and oxygen activity (10-105 Pa O2), using microthermogravimetric techniques. It has been shown that the oxidation of Ni-Cr and Ni-Na alloys, like that of pure nickel, follows strictly the parabolic rate law being thus diffusion controlled. In agreement with the defect model of Ni1-yO, it has been found that the oxidation rate of the Ni-Cr alloy is higher than that of pure nickel, the reaction rate is pressure independent and the activation energy of this process is lower. This implies that the concentration of double ionized cation vacancies in a Ni1-yO-Cr2O3 solid solution is fixed on a constant level by trivalent chromium ions, substitutionally incorporated into the cation sublattice of this oxide. In the case of the Ni-Na alloy, on the other hand, the oxidation rate is lower than that of pure nickel, the activation energy is higher and the oxidation rate increases more rapidly with oxygen pressure. These results can again be explained in terms of the doping effect, by assuming that univalent sodium ions dissolve substitutionally in the cation sublattice of nickel oxide.

  5. Tensile and pack compressive tests of some sheets of aluminum alloy, 1025 carbon steel, and chromium-nickel steel

    NASA Technical Reports Server (NTRS)

    Atchison, C S; Miller, James A

    1942-01-01

    Tensile and compressive stress-strain curves, stress-deviation curves, and secant modulus-stress curves are given for longitudinal and transverse specimens of 17S-T, 24S-T, and 24S-RT aluminum-alloy sheet in thicknesses from 0.032 to 0.081 inch, 1025 carbon steel sheet in thicknesses of 0.054 and 0.120 inch, and chromium-nickel steel sheet in thicknesses form 0.020 to 0.0275 inch. Significant differences were found between the tensile and the compressive stress-strain curves, and also the corresponding corollary curves; similarly, differences were found between the curves for the longitudinal and transverse directions. These differences are of particular importance in considering the compressive strength of aircraft structures made of thin sheet. They are explored further for the case of compression by giving tangent modulus-stress curves in longitudinal and transverse compression and dimensionless curves of the ratio of tangent modulus to Young's modulus and of the ratio of reduced modulus for a rectangular section to Young's modulus, both plotted against the ratio of stress to secant yield strength.

  6. Nickel detoxification and plant growth promotion by multi metal resistant plant growth promoting Rhizobium species RL9.

    PubMed

    Wani, Parvaze Ahmad; Khan, Mohammad Saghir

    2013-07-01

    Pollution of the biosphere by heavy metals is a global threat that has accelerated dramatically since the beginning of industrial revolution. The aim of the study is to check the resistance of RL9 towards the metals and to observe the effect of Rhizobium species on growth, pigment content, protein and nickel uptake by lentil in the presence and absence of nickel. The multi metal tolerant and plant growth promoting Rhizobium strain RL9 was isolated from the nodules of lentil. The strain not only tolerated nickel but was also tolerant o cadmium, chromium, nickel, lead, zinc and copper. The strain tolerated nickel 500 μg/mL, cadmium 300 μg/mL, chromium 400 μg/mL, lead 1,400 μg/mL, zinc 1,000 μg/mL and copper 300 μg/mL, produced good amount of indole acetic acid and was also positive for siderophore, hydrogen cyanide and ammonia. The strain RL9 was further assessed with increasing concentrations of nickel when lentil was used as a test crop. The strain RL9 significantly increased growth, nodulation, chlorophyll, leghaemoglobin, nitrogen content, seed protein and seed yield compared to plants grown in the absence of bioinoculant but amended with nickel The strain RL9 decreased uptake of nickel in lentil compared to plants grown in the absence of bio-inoculant. Due to these intrinsic abilities strain RL9 could be utilized for growth promotion as well as for the remediation of nickel in nickel contaminated soil.

  7. Environmental durability of electroplated black chromium

    NASA Technical Reports Server (NTRS)

    Lowery, J. R.

    1981-01-01

    A study was undertaken to determine the durability of nickel-black chromium plated aluminum in an outdoor rural industrial, and seacoast environment. Test panels were exposed to these environments for 60, 36, and 13 months, respectively. The results of this study showed that no significant optical degradation occurred from exposure to either of these environments, although a considerable amount of corrosion occurred on the panels exposed to the seacoast environment. The rural and industrial atmosphere produced only a slight amount of corrosion on test panels.

  8. Relative SHG measurements of metal thin films: Gold, silver, aluminum, cobalt, chromium, germanium, nickel, antimony, titanium, titanium nitride, tungsten, zinc, silicon and indium tin oxide

    NASA Astrophysics Data System (ADS)

    Che, Franklin; Grabtchak, Serge; Whelan, William M.; Ponomarenko, Sergey A.; Cada, Michael

    We have experimentally measured the surface second-harmonic generation (SHG) of sputtered gold, silver, aluminum, zinc, tungsten, copper, titanium, cobalt, nickel, chromium, germanium, antimony, titanium nitride, silicon and indium tin oxide thin films. The second-harmonic response was measured in reflection using a 150 fs p-polarized laser pulse at 1561 nm. We present a clear comparison of the SHG intensity of these films relative to each other. Our measured relative intensities compare favorably with the relative intensities of metals with published data. We also report for the first time to our knowledge the surface SHG intensity of tungsten and antimony relative to that of well known metallic thin films such as gold and silver.

  9. Effects of chromium, copper, nickel, and zinc on survival and feeding of the cladoceran Moina macrocopa

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wong, C.K.

    1992-10-01

    Heavy metals are widely recognized as highly toxic and dangerous. Past research activities on heavy metal pollution in Hong Kong have emphasized coastal environmentals. Since the main sources of heavy metals are the discharge and spillage of wastewater from electroplating factories, concentrations of heavy metals in streams and pools near industrial areas may be higher than those in coastal waters. Electroplating wastewater in Hong Kong contains high levels of chromium, copper, nickel and zinc. The toxicity of these heavy metals to the aquatic organisms has been extensively reviewed. Toxicity information for invertebrates shows that crustaceans are among the most sensitivemore » organisms. Of the crustacean species tested, cladocerans appear to be the most susceptibile. Cladocerans are important components of many aquatic ecosystems. Despite their importance in many freshwater communities and their sensitivity to heavy metal toxicity, information on the toxicity of heavy metals to cladocerans is limited except for several Daphnia species. In Hong Kong the freshwater cladoceran Moina macrocopa occurs in small ponds and rice paddies and is mass cultured by some farmers as a high quality fish food. The objectives of this study are to determine the effects of various heavy metals on the survival and feeding of M. macrocopa. 12 refs., 2 figs., 1 tab.« less

  10. Chromium Distribution between Liquid Slag and Matte Phases

    NASA Astrophysics Data System (ADS)

    Eric, R. Hurman

    The distribution of chromium between liquid silicate slags and copper-iron-nickel matte phases encountered in electric smelting of PGM containing South African sulphide concentrates were experimentally studied under controlled partial pressures of oxygen and sulphur. The reported experiments were conducted under silica saturation through the use of silica crucibles. Seven representative slag compositions were equilibrated with a typical sulphur deficient matte containing 18% Ni, 11% Cu, 42% Fe and 29% S. The slag constituents varied in the following ranges: SiO2: 42-58%, Al2O3: 3.5-9.0%, Fe2O3: 13-21%, MgO: 15.6-25%, CaO: 2-15%, Cr2O3: 0.2-3.5%. The slag and matte samples were synthetically prepared from pure components. The chromium content of the two phases was analysed chemically. According to the present available results of this ongoing research it was found that the partition of chromium to the matte phase decreased with an increase in the partial pressures of both oxygen and sulphur where the value of the distribution coefficient of chromium between the matte and the slag phase varied from as low as 0.07 to as high as 5.5.

  11. Quantitative in vivo biocompatibility of new ultralow-nickel cobalt-chromium-molybdenum alloys.

    PubMed

    Sonofuchi, Kazuaki; Hagiwara, Yoshihiro; Koizumi, Yuichiro; Chiba, Akihiko; Kawano, Mitsuko; Nakayama, Masafumi; Ogasawara, Kouetsu; Yabe, Yutaka; Itoi, Eiji

    2016-09-01

    Nickel (Ni) eluted from metallic biomaterials is widely accepted as a major cause of allergies and inflammation. To improve the safety of cobalt-chromium-molybdenum (Co-Cr-Mo) alloy implants, new ultralow-Ni Co-Cr-Mo alloys with and without zirconium (Zr) have been developed, with Ni contents of less than 0.01%. In the present study, we investigated the biocompatibility of these new alloys in vivo by subcutaneously implanting pure Ni, conventional Co-Cr-Mo, ultralow-Ni Co-Cr-Mo, and ultralow-Ni Co-Cr-Mo with Zr wires into the dorsal sides of mice. After 3 and 7 days, tissues around the wire were excised, and inflammation; the expression of IL-1β, IL-6, and TNF-α; and Ni, Co, Cr, and Mo ion release were analyzed using histological analyses, qRT-PCR, and inductively coupled plasma mass spectrometry (ICP-MS), respectively. Significantly larger amounts of Ni eluted from pure Ni wires than from the other wires, and the degree of inflammation depended on the amount of eluted Ni. Although no significant differences in inflammatory reactions were identified among new alloys and conventional Co-Cr-Mo alloys in histological and qRT-PCR analyses, ICP-MS analysis revealed that Ni ion elution from ultralow-Ni Co-Cr-Mo alloys with and without Zr was significantly lower than from conventional Co-Cr-Mo alloys. Our study, suggests that the present ultralow-Ni Co-Cr-Mo alloys with and without Zr have greater safety and utility than conventional Co-Cr-Mo alloys. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1505-1513, 2016. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  12. Filler metal alloy for welding cast nickel aluminide alloys

    DOEpatents

    Santella, Michael L.; Sikka, Vinod K.

    1998-01-01

    A filler metal alloy used as a filler for welding east nickel aluminide alloys contains from about 15 to about 17 wt. % chromium, from about 4 to about 5 wt. % aluminum, equal to or less than about 1.5 wt. % molybdenum, from about 1 to about 4.5 wt. % zirconium, equal to or less than about 0.01 wt. % yttrium, equal to or less than about 0.01 wt. % boron and the balance nickel. The filler metal alloy is made by melting and casting techniques such as are melting the components of the filler metal alloy and east in copper chill molds.

  13. Adverse effects of nickel in transosseous wires and surgical implants: literature review.

    PubMed

    Nwashindi, A; Dim, E M

    2014-01-01

    Transosseous wires used in the management of fractures are stainless steel alloys which contain nickel 14.5%, chromium 17.6%, iron 62.5% and molybdenum 2.8%. Gradual disintegration of the transosseous wires release nickel into the blood leading to increase nickel concentration in the blood. Nickel has been found to have some adverse systemic effects on the body. The aim of this paper is to discuss the sources of Nickel in the body as well as the systemic adverse effects of Nickel as a degradation product of stainless steel surgical implants. A study of pertinent literature on nickel as a content of stainless steel alloy used in implant surgery was done, taking note also of other sources of nickel in the body, the toxicokinetics of nickel and the related adverse effects of this metal and its compound in humans. As outcome,the sources of human exposure to nickel,distribution and metabolism of nickel in the body, host responseto stainless steel wires and the adverse effects of nickel in the body are presented. It may be necessary to discourage the use of wires or implants containing nickel in the management of fractures.The need for removal of these implants after they have served their purposes is emphasized.

  14. Study of alumina-trichite reinforcement of a nickel-based matric by means of powder metallurgy

    NASA Technical Reports Server (NTRS)

    Walder, A.; Hivert, A.

    1982-01-01

    Research was conducted on reinforcing nickel based matrices with alumina trichites by using powder metallurgy. Alumina trichites previously coated with nickel are magnetically aligned. The felt obtained is then sintered under a light pressure at a temperature just below the melting point of nickel. The halogenated atmosphere technique makes it possible to incorporate a large number of additive elements such as chromium, titanium, zirconium, tantalum, niobium, aluminum, etc. It does not appear that going from laboratory scale to a semi-industrial scale in production would create any major problems.

  15. Inter-rater agreement for a retrospective exposure assessment of asbestos, chromium, nickel and welding fumes in a study of lung cancer and ionizing radiation.

    PubMed

    Seel, E A; Zaebst, D D; Hein, M J; Liu, J; Nowlin, S J; Chen, P

    2007-10-01

    A retrospective exposure assessment of asbestos, welding fumes, chromium and nickel (in welding fumes) was conducted at the Portsmouth Naval Shipyard for a nested case-control study of lung cancer risk from external ionizing radiation. These four contaminants were included because of their potential to confound or modify the effect of a lung cancer-radiation relationship. The exposure assessment included three experienced industrial hygienists from the shipyard who independently assessed exposures for 3519 shop/job/time period combinations. A consensus process was used to resolve estimates with large differences. Final exposure estimates were linked to employment histories of the 4388 study subjects to calculate their cumulative exposures. Inter-rater agreement analyses were performed on the original estimates to better understand the estimation process. Although concordance was good to excellent (78-99%) for intensity estimates and excellent (96-99%) for frequency estimates, overall simple kappa statistics indicated only slight agreement beyond chance (kappa < 0.2). Unbalanced distributions of exposure estimates partly contributed to the weak observed overall inter-rater agreement. Pairwise weighted kappa statistics revealed better agreement between two of the three panelists (kappa = 0.19-0.65). The final consensus estimates were similar to the estimates made by these same two panelists. Overall welding fume exposures were fairly stable across time at the shipyard while asbestos exposures were higher in the early years and fell in the mid-1970s. Mean cumulative exposure for all study subjects was 520 fiber-days cc(-1) for asbestos and 1000 mg-days m(-3) for welding fumes. Mean exposure was much lower for nickel (140 microg-days m(-3)) and chromium (45 microg-days m(-3)). Asbestos and welding fume exposure estimates were positively associated with lung cancer in the nested case-control study. The radiation-lung cancer relationship was attenuated by the inclusion

  16. Several braze filler metals for joining an oxide-dispersion-strengthened nickel-chromium-aluminum alloy

    NASA Technical Reports Server (NTRS)

    Gyorgak, C. A.

    1975-01-01

    An evaluation was made of five braze filler metals for joining an aluminum-containing oxide dispersion-strengthened (ODS) alloy, TD-NiCrAl. All five braze filler metals evaluated are considered suitable for joining TD-NiCrAl in terms of wettability and flow. Also, the braze alloys appear to be tolerant of slight variations in brazing procedures since joints prepared by three sources using three of the braze filler metals exhibited similar brazing characteristics and essentially equivalent 1100 C stress-rupture properties in a brazed butt-joint configuration. Recommendations are provided for brazing the aluminum-containing ODS alloys.

  17. Equations for nickel-chromium wire heaters of column transfer lines in gas chromatographic-electroantennographic detection (GC-EAD).

    PubMed

    Byers, John A

    2004-05-30

    Heating of chromatographic columns, transfer lines, and other devices is often required in neuroscience research. For example, volatile compounds passing through a capillary column of a gas chromatograph (GC) can be split, with half exiting the instrument through a heated transfer line to an insect antenna or olfactory sensillum for electroantennographic detector (GC-EAD) recordings. The heated transfer line is used to prevent condensation of various chemicals in the capillary that would otherwise occur at room temperature. Construction of such a transfer line heater is described using (80/20%) nickel-chromium heating wire wrapped in a helical coil and powered by a 120/220 V ac rheostat. Algorithms were developed in a computer program to estimate the voltage at which a rheostat should be set to obtain the desired heater temperature for a specific coil. The coil attributes (radius, width, number of loops, or length of each loop) are input by the user, as well as AWG size of heating wire and desired heater temperature. The program calculates total length of wire in the helix, resistance of the wire, amperage used, and the voltage to set the rheostat. A discussion of semiochemical isolation methods using the GC-EAD and bioassays is presented.

  18. Filler metal alloy for welding cast nickel aluminide alloys

    DOEpatents

    Santella, M.L.; Sikka, V.K.

    1998-03-10

    A filler metal alloy used as a filler for welding cast nickel aluminide alloys contains from about 15 to about 17 wt. % chromium, from about 4 to about 5 wt. % aluminum, equal to or less than about 1.5 wt. % molybdenum, from about 1 to about 4.5 wt. % zirconium, equal to or less than about 0.01 wt. % yttrium, equal to or less than about 0.01 wt. % boron and the balance nickel. The filler metal alloy is made by melting and casting techniques such as are melting the components of the filler metal alloy and cast in copper chill molds. 3 figs.

  19. Surface passivity largely governs the bioaccessibility of nickel-based powder particles at human exposure conditions.

    PubMed

    Hedberg, Yolanda S; Herting, Gunilla; Latvala, Siiri; Elihn, Karine; Karlsson, Hanna L; Odnevall Wallinder, Inger

    2016-11-01

    The European chemical framework REACH requires that hazards and risks posed by chemicals, including alloys and metals, are identified and proven safe for humans and the environment. Therefore, differences in bioaccessibility in terms of released metals in synthetic biological fluids (different pH (1.5-7.4) and composition) that are relevant for different human exposure routes (inhalation, ingestion, and dermal contact) have been assessed for powder particles of an alloy containing high levels of nickel (Inconel 718, 57 wt% nickel). This powder is compared with the bioaccessibility of two nickel-containing stainless steel powders (AISI 316L, 10-12% nickel) and with powders representing their main pure alloy constituents: two nickel metal powders (100% nickel), two iron metal powders and two chromium metal powders. X-ray photoelectron spectroscopy, microscopy, light scattering, and nitrogen absorption were employed for the particle and surface oxide characterization. Atomic absorption spectroscopy was used to quantify released amounts of metals in solution. Cytotoxicity (Alamar blue assay) and DNA damage (comet assay) of the Inconel powder were assessed following exposure of the human lung cell line A549, as well as its ability to generate reactive oxygen species (DCFH-DA assay). Despite its high nickel content, the Inconel alloy powder did not release any significant amounts of metals and did not induce any toxic response. It is concluded, that this is related to the high surface passivity of the Inconel powder governed by its chromium-rich surface oxide. Read-across from the pure metal constituents is hence not recommended either for this or any other passive alloy. Copyright © 2016 The Author(s). Published by Elsevier Inc. All rights reserved.

  20. Interdiffusion in the Ni/TD-NiCr and Cr/TD-NiCr systems

    NASA Technical Reports Server (NTRS)

    Pawar, A. V.; Tenney, D. R.

    1974-01-01

    The diffusion of Ni and Cr into TD-NiCr has been studied over the 900 to 1100 C temperature range. The diffusion couples were prepared by electroplating Cr and Ni on polished TD-NiCr wafers. Concentration profiles produced as a result of isothermal diffusion at 905, 1000, and 1100 C were determined by electron microprobe analysis. The Boltzmann-Matano analysis was used to determine concentration-dependent diffusion coefficients which were found to compare favorably with previously reported values. These data suggest that 2 vol % ThO2 distribution has no appreciable effect on the rates of diffusion in TD-NiCr with a large grain size. This supports the view that an inert dispersoid in an alloy matrix will not in itself lead to enhanced diffusion unless a short-circuit diffusion structure is stabilized.

  1. Structural, optical and dielectric properties of pure and chromium (Cr) doped nickel oxide nanoparticles

    NASA Astrophysics Data System (ADS)

    Gupta, Jhalak; Ahmed, Arham S.

    2018-05-01

    The pure and Cr doped nickel oxide (NiO) nanoparticles have been synthesized by cost effective co-precipitation method having nickel nitrate as initial precursor. The synthesized samples were characterized by X-Ray diffraction (XRD), UV-Visible Spectroscopy(UV-Vis) and LCR meter for structural, optical and dielectric properties respectively. The crystallite size of pure nickel oxide nanoparticles characterized by XRD using Debye Scherer's formula was found to be 21.7nm and the same decreases on increasing Cr concentration whereas optical and dielectric properties were analyzed by UV-Vis and LCR meter respectively. The energy band gaps were determined by UV-Vis using Tauc relation.

  2. Elemental speciation for chromium in chromium picolinate products

    NASA Astrophysics Data System (ADS)

    Ding, Hong; Olson, Lisa K.; Caruso, Joseph A.

    1996-12-01

    Chromium picolinate products have been examined for different forms of chromium, using chromatographic separation and inductively coupled plasma mass spectrometric detection. The brands we evaluated contained no detectable amount of elemental chromium(VI), the toxic form. Since chromium picolinate might have other chromium forms as impurities, different products may contain different forms of chromium species. Compared with ion-exchange, reversed-phase chromatography showed excellent chromium recovery based on the amount stated on the product label.

  3. Changes in oxidation state of chromium during LDEF exposure

    NASA Technical Reports Server (NTRS)

    Golden, Johnny L.

    1992-01-01

    The solar collector used for the McDonnell-Douglas Cascade Variable Heat Pipe, Experiment A0076 (Michael Grote - Principal Investigator) was finished with black chromium plating as a thermal control coating. The coating is metallic for low emittance, and is finely microcrystalline to a dimension which yields its high absorptivity. An underplate of nickel was applied to the aluminum absorber plate in order to achieve optimal absorptance characteristics from the black chromium plate surface. Experiment A0076 was located at tray position F9, receiving a projected 8.7 x 10 exp 21 atomic oxygen atoms/sq cm and 11,200 ESH solar radiation. During retrieval, it was observed that the aluminized kapton thermal blankets covering most of the tray were severely eroded by atomic oxygen, and that a 'flap' of aluminum foil was overlaying a roughly triangular shaped portion of the absorber panel. The aluminum foil 'flap' was lost sometime between the Long Duration Exposure Facility (LDEF) retrieval and deintegration. At deintegration, the black chromium was observed to have discolored where it had been covered by the foil 'flap'. A summary of the investigation into the cause of the discoloration is presented.

  4. Phase control of austenitic chrome-nickel steel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Korkh, M. K., E-mail: KorkhMK@imp.uran.ru; Davidov, D. I., E-mail: davidov@imp.uran.ru; Korkh, J. V., E-mail: Korkh@imp.uran.ru

    2015-10-27

    The paper presents the results of the comparative study of the possibilities of different structural and magnetic methods for detection and visualization of the strain-induced martensitic phase in low carbon austenitic chromium-nickel steel. Results of TEM, SEM, optical microscopy, atomic and magnetic force microscopy, and magnetic measurements are presented. Amount of the magnetic strain-induced martensite was estimated. We pioneered magnetic force microscopic images of the single domain cluster distribution of the strain-induced martensite in austenite-ferrite materials.

  5. Effects of composition and testing conditions on oxidation behavior of four cast commercial nickel-base superalloys

    NASA Technical Reports Server (NTRS)

    Lowell, C. E.; Probst, H. B.

    1974-01-01

    Four cast nickel-base superalloys were oxidized at 1000 and 1100 C for times up to 100 hr in static air and a Mach 1 gas stream. The oxidation resistance was judged by weight change, metal thickness loss, depletion-zone formation, and oxide formation and morphology. The alloys which formed mostly nickel aluminate (NiAl2O4) and aluminum oxide (Al2O3) (B-1900, VIA, and to a lesser extent 713C) were more oxidation resistant. Poorer oxidation resistance was associated with the appearance of chromium sesquioxide (Cr2O3) and chromite spinel (738X). Refractory metal content had little effect on oxidation resistance. Refractory metals appeared in the scale as tapiolite (NiM2O6, where M represents the refractory metal). Thermal cycling in static air appeared to supply sufficient data for the evaluation of oxidation resistance, especially for alloys which form oxides of low volatility. For alloys of higher chromium levels with high propensities toward forming a chromium-bearing scale of higher volatility, testing under conditions of high gas velocity is necessary to assess fully the behavior of the alloy.

  6. Evaluation of Non-Chromate Passivations on Electroplated gamma-Phase Zinc Nickel

    NASA Astrophysics Data System (ADS)

    Volz, Steven Michael

    This research focused on the corrosion response and electrochemical behavior of electroplated low hydrogen embrittlement alkaline gamma-phase zinc nickel with passivation layers. The motivation was the need to replace hexavalent chromium conversion coatings in military grade electrical systems with a more environment friendly alternative. The passivation layers were employed for the purpose of mitigating corrosion attack while maintaining low contact resistance. Trivalent chromium-based passivations and cerium-based passivations were compared against the currently used hexavalent chromium conversion coating. The coating systems were compared using electrochemical impedance spectroscopy, cyclic potentiodymanic scans, salt spray exposure testing, electrical resistance measurements, microstructure analysis, and compositional analysis. Coating systems with lower open circuit had a lower corrosion current and performed better during salt spray testing. All of the systems evaluated had corrosion products consistent with oxidized zinc compounds but the morphology of the passivation was dependent on the passivation. The electrical contact resistance ranged from 1 to 108 mO/cm 2, after salt spray testing. Two versions of Trivalent chromium-based passivations, were able to meet military performance specifications after corrosion testing.

  7. Understanding the roles of the strategic element cobalt in nickel base superalloys

    NASA Technical Reports Server (NTRS)

    Stephens, J. R.; Dreshfield, R. L.

    1983-01-01

    The United States imports over 90% of its cobalt, chromium, columbium, and tantalum, all key elements in high temperature nickel base superalloys for aircraft gas turbine disks and airfoils. Research progress in understanding the roles of cobalt and some possible substitutes effects on microstructure, mechanical properties, and environmental resistance of turbine alloys is discussed.

  8. Brushing-Induced Surface Roughness of Two Nickel Based Alloys and a Titanium Based Alloy: A Comparative Study - In Vitro Study

    PubMed Central

    Acharya, B L Guruprasanna; Nadiger, Ramesh; Shetty, Bharathraj; Gururaj, G; Kumar, K Naveen; Darshan, D D

    2014-01-01

    Background: Alloys with high nickel content have been increasingly used in dentistry. Alloys have high corrosion rates when exposed to chemical or physical forces that are common intra orally. Titanium is the most biocompatible materials for crowns, fixed partial dentures and implants in the present use, but paradoxically the self-protective oxide film on the titanium can be affected by excessive use of the most common preventive agents in dentistry. Therefore, this study is undertaken in order to draw attention toward the potential effect of prophylactic brushing in a saline medium. Materials and Methods: Forty-five wax patterns in equal dimensions of 10 mm × 10 mm × 2 mm were cast in titanium (Grade II) and nickel-chromium. Of the 45 wax patterns, 15 wax patterns were used for preparing cast titanium samples and 30 wax patterns were used for preparing cast nickel-chromium samples and polished. These samples were divided into three groups of 15 samples each. They are brushed for 48 h each clinically simulating 2 years of brushing in a saline tooth paste medium. The surface roughnesses of the samples were evaluated using profilometer, scanning electron microscopes and energy dispersive spectroscopy. Results were subjected to statistical analysis. Results: The statistical analysis of the Rz and Ra surface roughness values were calculated. Significant difference of surface roughness was present in the titanium samples compared to that of the machine-readable cataloguing and Wirolloy (nickel-chromium) samples after the study. To know the difference in the values of all samples before and after, Student’s paired t-test was carried out. Results showed that there is a significant change in the Rz and Ra values of titanium samples. Conclusion: The present findings suggest that, prophylactic brushing with the fluoridated toothpaste have an effect on the surface roughness of titanium and also to a certain extent, on nickel-chromium. Therefore, careful consideration must

  9. Corrosion Characterization in Nickel Plated 110 ksi Low Alloy Steel and Incoloy 925: An Experimental Case Study

    NASA Astrophysics Data System (ADS)

    Thomas, Kiran; Vincent, S.; Barbadikar, Dipika; Kumar, Shresh; Anwar, Rebin; Fernandes, Nevil

    2018-04-01

    Incoloy 925 is an age hardenable Nickel-Iron-Chromium alloy with the addition of Molybdenum, Copper, Titanium and Aluminium used in many applications in oil and gas industry. Nickel alloys are preferred mostly in corrosive environments where there is high concentration of H2S, CO2, chlorides and free Sulphur as sufficient nickel content provides protection against chloride-ion stress-corrosion cracking. But unfortunately, Nickel alloys are very expensive. Plating an alloy steel part with nickel would cost much lesser than a part make of nickel alloy for large quantities. A brief study will be carried out to compare the performance of nickel plated alloy steel with that of an Incoloy 925 part by conducting corrosion tests. Tests will be carried out using different coating thicknesses of Nickel on low alloy steel in 0.1 M NaCl solution and results will be verified. From the test results we can confirm that Nickel plated low alloy steel is found to exhibit fairly good corrosion in comparison with Incoloy 925 and thus can be an excellent candidate to replace Incoloy materials.

  10. Influence of Chemical Composition on Rupture Properties at 1200 Degrees F. of Forged Chromium-Cobalt-Nickel-Iron Base Alloys in Solution-Treated and Aged Condition

    NASA Technical Reports Server (NTRS)

    Reynolds, E E; Freeman, J W; White, A E

    1951-01-01

    The influence of systematic variations of chemical composition on rupture properties at 1200 degrees F. was determined for 62 modifications of a basic alloy containing 20 percent chromium, 20 percent nickel, 20 percent cobalt, 3 percent molybdenum, 2 percent tungsten, 1 percent columbium, 0.15 percent carbon, 1.7 percent manganese, 0.5 percent silicon, 0.12 percent nitrogen and the balance iron. These modifications included individual variations of each of 10 elements present and simultaneous variations of molybdenum, tungsten, and columbium. Laboratory induction furnace heats were hot-forged to round bar stock, solution-treated at 2200 degrees F., and aged at 1400 degrees F. The melting and fabrication conditions were carefully controlled in order to minimize all variable effects on properties except chemical composition. Information is presented which indicates that melting and hot-working conditions play an important role in high-temperature properties of alloys of the type investigated.

  11. Diamondlike carbon coating as a galvanic corrosion barrier between dental implant abutments and nickel-chromium superstructures.

    PubMed

    Ozkomur, Ahmet; Erbil, Mehmet; Akova, Tolga

    2013-01-01

    The objectives of this study were to evaluate the galvanic corrosion behavior between titanium and nickel-chromium (Ni-Cr) alloy, to investigate the effect of diamondlike carbon (DLC) coating over titanium on galvanic corrosion behavior between titanium and Ni-Cr alloy, and to evaluate the effect of DLC coating over titanium abutments on the fit and integrity of prosthetic assemblies by scanning electron microcopy (SEM). Five Ni-Cr and 10 titanium disks with a diameter of 5 mm and thickness of 3 mm were prepared. DLC coating was applied to five titanium disks. Electrode samples were prepared, and open circuit potential measurements, galvanic current measurements over platinum electrodes, and potentiodynamic polarization tests were carried out. For the SEM evaluation, 20 Ni-Cr alloy and 10 gold alloy superstructures were cast and prepared over 30 abutments. DLC coating was applied to 10 of the abutments. Following the fixation of prosthetic assemblies, the samples were embedded in acrylic resin and cross sectioned longitudinally. Internal fit evaluations were carried out through examination of the SEM images. Titanium showed more noble and electrochemically stable properties than Ni-Cr alloy. DLC coating over the cathode electrode served as an insulating film layer over the surface and prevented galvanic coupling. Results of the SEM evaluations indicated that the DLC-coated and titanium abutments showed no statistically significant difference in fit. Hence, no adverse effects on the adaptation of prosthetic components were found with the application of DLC coating over abutment surfaces. DLC coating might serve as a galvanic corrosion barrier between titanium abutments and Ni-Cr superstructures.

  12. Evaluation of aquatic toxicities of chromium and chromium-containing effluents in reference to chromium electroplating industries.

    PubMed

    Baral, A; Engelken, R; Stephens, W; Farris, J; Hannigan, R

    2006-05-01

    This study evaluated aquatic toxicities of chromium and chromium-containing laboratory samples representative of effluents from chromium electroplating industries, and compared the aquatic environmental risks of hexavalent and trivalent chromium electroplating operations. Trivalent chromium electroplating has emerged as an acceptable alternative to hazardous hexavalent chromium electroplating. This process substitution has reduced the human health impact in the workplace and minimized the production of hazardous sludge regulated under the Resource Conservation and Recovery Act (RCRA). The thrust behind this research was to investigate whether trivalent chromium electroplating operations have lower adverse impacts on standardized toxicity test organisms. Ceriodaphnia dubia and Pimephales promelas were used to investigate toxicities of trivalent chromium (Cr (III)), hexavalent chromium (Cr (VI)), and industrial effluents. In agreement with previous studies, Cr (III) was found to be less toxic than Cr (VI). Despite having several organic and inorganic constituents in the effluents obtained from trivalent chromium plating baths, they exhibited less adverse effects to C. dubia than effluents obtained from hexavalent chromium electroplating baths. Thus, transition from hexavalent to trivalent chromium electroplating processes may be justified. However, because of the presence of organic constituents such as formate, oxalate, and triethylene glycol in effluents, trivalent chromium electroplating operations may face additional regulatory requirements for removal of total organic carbon.

  13. Chromium Vaporization Reduction by Nickel Coatings For SOEC Interconnect Materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michael V. Glazoff; Sergey N. Rashkeev; J. Stephen Herring

    2014-09-01

    The vaporization of Cr-rich volatile species from interconnect materials is a major source of degradation that limits the lifetime of planar solid oxide devices systems with metallic interconnects, including Solid Oxide Electrolysis Cells, or SOECs. Some metallic coatings (Ni, Co, and Cu) significantly reduce the Cr release from interconnects and slow down the oxide scale growth on the steel substrate. To shed additional light upon the mechanisms of such protection and find a suitable coating material for ferritic stainless steel materials, we used a combination of first-principles calculations, thermodynamics, and diffusion modeling to investigate which factors determine the quality ofmore » the Ni metallic coating at stainless steel interconnector. We found that the Cr migration in Ni coating is determined by a delicate combination of the nickel oxidation, Cr diffusion, and phase transformation processes. Although the formation of Cr2O3 oxide is more exothermic than that of NiO, the kinetic rate of the chromia formation in the coating layer and its surface is significantly reduced by the low mobility of Cr in nickel oxide and in NiCr2O4 spinel. These results are in a good agreement with diffusion modeling for Cr diffusion through Ni coating layer on the ferritic 441 steel substrate.« less

  14. Diffusion in thoriated and nonthoriated nickel and nickel-chromium alloys at 1260 C

    NASA Technical Reports Server (NTRS)

    Whittenberger, J. D.

    1972-01-01

    Various solid-solid diffusion couples were assembled from thoriated and nonthoriated nickel-base alloys, welded, and diffusion annealed at 1260 C. Concentration profiles indicated that a thoria dispersion does not affect diffusion in Cr(alloy):Ni and Ni-4.8Al:Ni types of couples unless a fine grain structure is retained by the thoria particles. Metallography revealed the presence of thoria-free bands in the thoriated-Ni side of the diffusion zone. The bands contained grain boundaries and, in some cases, non-Kirkendall porosity. A mechanism based on the operation of vacancy sources is proposed to explain the thoria-free bands. In addition, a particular DS-NiCr:Ni couple had negligible Kirkendall porosity. This behavior was related to the grain structure of the particular lot of DS-NiCr.

  15. Sodium sulfur container with chromium/chromium oxide coating

    DOEpatents

    Ludwig, Frank A.; Higley, Lin R.

    1981-01-01

    A coating of chromium/chromium oxide is disclosed for coating the surfaces of electrically conducting components of a sodium sulfur battery. This chromium/chromium oxide coating is placed on the surfaces of the electrically conducting components of the battery which are in contact with molten polysulfide and sulfur reactants during battery operation.

  16. Monitoring of chromium and nickel in biological fluids of grinders grinding stainless steel.

    PubMed

    Stridsklev, Inger Cecilie; Schaller, Karl-Heinz; Langård, Sverre

    2007-04-01

    Stainless steel (SS) welders usually spend some of their working time grinding, to finish and smoothen the welding groove. The aim of this study was to investigate possible relations between the concentrations of nickel (Ni) and chromium (Cr) in the work atmosphere generated by grinders grinding SS, and to compare the air levels to the levels of Cr and Ni in their biological fluids. Hereby, it might be possible to identify the contribution of grinding to the levels of Cr and Ni in biological fluids in SS welders. Also the airborne levels of Cr and Ni in SS grinders were compared to corresponding levels in SS welders. The subjects examined in this study were selected among SS grinders not performing welding. Nine grinders were monitored for 1 workweek, measuring Cr and Ni in air, blood and urine. They were questioned about their exposure to Cr and Ni during their working careers. Air levels of total Cr up to 95 microg/m(3) and Ni levels up to 25 microg/m(3) were measured. Chromium(VI) (Cr(VI)) was detectable only in five air samples; the levels in the remaining samples were below the detection limit. The levels of Cr in blood and urine were also low. The levels of Ni in urine were close to those for MMA and MIG/MAG SS welders. In spite of high levels of total Cr and Ni observed in air, the levels found in biological fluids were low. The Cr levels in more than 50% of the whole blood and red cell samples and about 1/3 of the Cr-plasma levels were below the detection limits. The mean blood levels for Cr were 0.43, 0.60 and 0.35 microg/l, in whole blood, plasma and red cells, respectively. The mean levels for Cr in the urine was 1.6, 1.4 and 1.4 microg/g creatinine for the first void, just before and just after work. For Ni the mean blood levels were 0.87 microg/l in whole blood and 0.68 microg/l in plasma. The mean levels and ranges of Ni from the first void, just before and after work in urine were 3.79 microg/g creatinine, 3.39 and 4.56, respectively. The Cr

  17. Transition metal sensing by Toll-like receptor-4: next to nickel, cobalt and palladium are potent human dendritic cell stimulators.

    PubMed

    Rachmawati, Dessy; Bontkes, Hetty J; Verstege, Marleen I; Muris, Joris; von Blomberg, B Mary E; Scheper, Rik J; van Hoogstraten, Ingrid M W

    2013-06-01

    Nickel was recently identified as a potent activator of dendritic cells through ligating with human Toll-like receptor (TLR)-4. Here, we studied an extended panel of transition metals neighbouring nickel in the periodic table of elements, for their capacity to activate human monocyte-derived dendritic cells (MoDCs). The panel included chromium, cobalt, and palladium, all of which are known to be frequent clinical sensitizers. MoDC activation was monitored by assessment of release of the pro-inflammatory mediator interleukin (IL)-8, a major downstream result of TLR ligation. Results The data obtained in the present study show that cobalt and palladium also have potent MoDC-activating capacities, whereas copper and zinc, but not iron and chromium, have low but distinct MoDC-activating potential. Involvement of endotoxin contamination in MoDC activation was excluded by Limulus assays and consistent stimulation in the presence of polymyxin B. The critical role of TLR4 in nickel-induced, cobalt-induced and palladium-induced activation was confirmed by essentially similar stimulatory patterns obtained in an HEK293 TLR4/MD2 transfectant cell line. Given the adjuvant role of costimulatory danger signals, the development of contact allergies to the stimulatory metals may be facilitated by signals from direct TLR4 ligation, whereas other metal sensitizers, such as chromium, may rather depend on microbial or tissue-derived cofactors to induce clinical sensitization. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Electrochemical corrosion behaviour of nickel chromium-chromium carbide coating by HVOF process

    NASA Astrophysics Data System (ADS)

    Amudha, A.; Nagaraja, H. S.; Shashikala, H. D.

    2018-04-01

    To overcome the corrosion problem in marine industry, coatings are one of the most economical solutions. In this paper, the corrosion behaviour of 25(NiCr)-75Cr3C2 cermet coating on low carbon steel substrate by HVOF process is studied. Different phases such as Cr7C3 and Cr3C2, along with Ni and chromium oxide(Cr3O2) constituents present in the coating were revealed by X-Ray Diffraction (XRD) analysis. The morphology of the coating obtained by scanning electron microscope (SEM) gave confirmation for the XRD analysis. Electrochemical corrosion techniques such as Linear Polarization Resistance (LPR) and Electrochemical Impedance Spectroscopy (EIS) were used to study the corrosion behaviour of the cermet in 3.5wt% NaCl electrolyte solution. The corrosion current density of the coated sample and substrate were found to be 6.878µA/cm-2 and 21.091µA/cm-2 respectively. The Nyquist Impedance spectra were used to derive an equivalent circuit to analyze the interaction between the coating and electrolyte. The Bode Impedance plots obtained by EIS for the coating showed a typical passive material capacitive behaviour, indicated by medium to low frequency with phase angle approaching -60o, suggesting that a stable film is formed on the tested material in the electrolyte used.

  19. Effects of surface finishing conditions on the biocompatibility of a nickel-chromium dental casting alloy.

    PubMed

    McGinley, Emma Louise; Coleman, David C; Moran, Gary P; Fleming, Garry J P

    2011-07-01

    To assess the effects of surface finishing condition (polished or alumina particle air abraded) on the biocompatibility of direct and indirect exposure to a nickel-chromium (Ni-Cr) d.Sign®10 dental casting alloy on oral keratinocytes. Biocompatibility was performed by assessing cellular viability and morphology, metabolic activity, cellular toxicity and presence of inflammatory cytokine markers. Discs of d.Sign®10 were cast, alumina particle air abraded and half were polished before surface roughness was determined by profilometry. Biocompatibility was assessed by placing the discs directly or indirectly (with immersion solutions) into contact with TR146 monolayers. Metal ion release was determined by ICP-MS. Cell viability was assessed by trypan blue dye exclusion, metabolic activity by XTT and cellular toxicity by LDH. Inflammatory cytokine analysis was performed using sandwich ELISAs. The mean polished Ra value was significantly reduced (P<0.001) compared with the alumina particle air abraded discs but metal ion release was significantly increased for the polished discs. Significant reductions in cell density of polished compared with alumina particle air abraded discs was observed following direct or indirect exposure. A significant reduction in metabolic activity, increase in cellular toxicity and an increase in the presence of inflammatory cytokine markers was highlighted for the polished relative to the alumina particle air abraded discs at 24h. Finishing condition of the Ni-Cr dental alloy investigated has important clinical implications. The approach of employing cell density and morphology, metabolic activity, cellular toxicity levels and inflammatory marker responses to TR146 epithelial cells combined with ICP-MS afforded the authors an increased insight into the complex processes dental alloys undergo in the oral environment. Copyright © 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  20. Absorption of metals in mulloway (Argyrosomus japonicus) after ingesting nickel-plated carbon-steel hooks.

    PubMed

    McGrath, Shane P; Reichelt-Brushett, Amanda J; Butcher, Paul A; Cairns, Stuart C

    2014-08-01

    Previous research has alluded to the potential of metals being absorbed by fish after ingesting fishing hooks, which may have adverse effects on fish health and the organisms that consume them. Subsequently, this study aimed to quantify the potential of mulloway (Argyrosomus japonicus) to absorb metals during the decay of ingested nickel-plated carbon-steel hooks. Twenty-five treatment fish were allowed to ingest nickel-plated carbon-steel hooks during angling and then monitored with 25 controls (untreated fish) for up to 42 days for hook ejection and mortality. Blood, liver and muscle samples were collected from treatment, control and 14 wild-caught individuals to determine the concentrations of chromium, cobalt, copper, iron, manganese and nickel. The results showed that increased oxidation influenced hook ejection, and that hook-ingested fish had significantly elevated concentrations of nickel in their liver and blood, but not muscle. This research has shown that there is an avenue for metal absorption from ingested hooks. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Residues of chromium, nickel, cadmium and lead in Rook Corvus frugilegus eggshells from urban and rural areas of Poland.

    PubMed

    Orłowski, Grzegorz; Kasprzykowski, Zbigniew; Dobicki, Wojciech; Pokorny, Przemysław; Wuczyński, Andrzej; Polechoński, Ryszard; Mazgajski, Tomasz D

    2014-08-15

    We examined the concentrations of chromium (Cr), nickel (Ni), cadmium (Cd) and lead (Pb) in Rook Corvus frugilegus eggshells from 43 rookeries situated in rural and urban areas of western (=intensive agriculture) and eastern (=extensive agriculture) Poland. We found small ranges in the overall level of Cr (the difference between the extreme values was 1.8-fold; range of concentrations=5.21-9.40 Cr ppm), Ni (3.5-fold; 1.15-4.07 Ni ppm), and Cd (2.6-fold; 0.34-0.91 Cd ppm), whereas concentrations of Pb varied markedly, i.e. 6.7-fold between extreme values (1.71-11.53 Pb ppm). Eggshell levels of these four elements did not differ between rural rookeries from western and eastern Poland, but eggshells from rookeries in large/industrial cities had significantly higher concentrations of Cr, Ni and Pb than those from small towns and villages. Our study suggests that female Rooks exhibited an apparent variation in the intensity of trace metal bioaccumulation in their eggshells, that rapid site-dependent bioaccumulation of Cu, Cr, Ni and Pb occurs as a result of the pollution gradient (rural

  2. Nickel speciation in several serpentine (ultramafic) topsoils via bulk synchrotron-based techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Siebecker, Matthew G.; Chaney, Rufus L.; Sparks, Donald L.

    2017-07-01

    Serpentine soils have elevated concentrations of trace metals including nickel, cobalt, and chromium compared to non-serpentine soils. Identifying the nickel bearing minerals allows for prediction of potential mobility of nickel. Synchrotron-based techniques can identify the solid-phase chemical forms of nickel with minimal sample treatment. Element concentrations are known to vary among soil particle sizes in serpentine soils. Sonication is a useful method to physically disperse sand, silt and clay particles in soils. Synchrotron-based techniques and sonication were employed to identify nickel species in discrete particle size fractions in several serpentine (ultramafic) topsoils to better understand solid-phase nickel geochemistry. Nickel commonlymore » resided in primary serpentine parent material such as layered-phyllosilicate and chain-inosilicate minerals and was associated with iron oxides. In the clay fractions, nickel was associated with iron oxides and primary serpentine minerals, such as lizardite. Linear combination fitting (LCF) was used to characterize nickel species. Total metal concentration did not correlate with nickel speciation and is not an indicator of the major nickel species in the soil. Differences in soil texture were related to different nickel speciation for several particle size fractionated samples. A discussion on LCF illustrates the importance of choosing standards based not only on statistical methods such as Target Transformation but also on sample mineralogy and particle size. Results from the F-test (Hamilton test), which is an underutilized tool in the literature for LCF in soils, highlight its usefulness to determine the appropriate number of standards to for LCF. EXAFS shell fitting illustrates that destructive interference commonly found for light and heavy elements in layered double hydroxides and in phyllosilicates also can occur in inosilicate minerals, causing similar structural features and leading to false positive

  3. Rare occupational cause of nasal septum perforation: Nickel exposure.

    PubMed

    Bolek, Ertugrul Cagri; Erden, Abdulsamet; Kulekci, Cagri; Kalyoncu, Umut; Karadag, Omer

    2017-10-06

    Many etiologies are held accountable for nasal septum perforations. Topical nasal drug usage, previous surgeries, trauma, nose picking, squamous cell carcinoma, some rheumatological disorders such as granulomatosis with polyangiitis (Wegener granulomatosis), some infectious diseases such as syphilis and leprosy are among the causes of the perforations. Occupational heavy metal exposures by inhalation rarely may also cause nasal septum perforation. Here, we present a 29-year-old patient without any known diseases, who is a worker at a metallic coating and nickel-plating factory, referred for investigation of his nasal cartilage septum perforation from an otorhinolaryngology clinic. The patient questioning, physical examination and laboratory assessment about rheumatic and infectious diseases were negative. There was a metallic smell in the breath during the physical examination. The analysis showed serum nickel level at 31 μg/l and urine nickel at 18 μg/l (84.11 μg/g creatinine). Other possible serum and urine heavy metal levels were within normal ranges. Nickel exposure is usually together with other heavy metals (chromium or cadmium), it is rarely alone. Nickel ingested by inhalation usually leads to respiratory problems such as reduced olfactory acuity, ulcers, septum perforation or tumors of the nasal sinuses. This case demonstrates the importance of occupational anamnesis and awareness of diagnosis. Int J Occup Med Environ Health 2017;30(6):963-967. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  4. Travellers' diarrhoea: Impact of TD definition and control group design on study results.

    PubMed

    Lääveri, Tinja; Pakkanen, Sari H; Kirveskari, Juha; Kantele, Anu

    2018-02-02

    Travellers' diarrhoea (TD) is a common health problem among visitors to the (sub)tropics. Much research deals with aetiology, prevention, and post-infection sequalae, yet the data may not allow comparisons due to incompatible definitions of TD and No TD control groups. The impact of defining TD and No TD control groups was explored by revisiting our recent data. We set up two TD groups: classical TD i.e. ≥3 loose or liquid stools/day and WHO TD (diarrhoea as defined by the WHO) i.e. any diarrhoea, and four No TD groups by TD definition and timing (no classical/WHO TD during travel, no ongoing classical/WHO TD). TD was recorded for 37% versus 65% of subjects when using classical versus WHO definitions, respectively; the proportions of the various pathogens proved similar. The strictest criterion for the No TD control group (no WHO TD during travel) yielded pathogens among 61% and the least strict (no ongoing classical TD) among 73% of the travellers; the differences were greatest for enteroaggregative Escherichia coli and Campylobacter. Definition of TD and control group design substantially impact on TD study results. The WHO definition yields more cases, but the pathogen selection is similar by both definitions. Design of the No TD control group was found critical: only those remaining asymptomatic throughout the journey should be included. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Isolation and characterization of Bacillus cereus IST105 from electroplating effluent for detoxification of hexavalent chromium.

    PubMed

    Naik, Umesh Chandra; Srivastava, Shaili; Thakur, Indu Shekhar

    2011-08-01

    Electroplating industries are the main sources of heavy metals, chromium, nickel, lead, zinc, cadmium and copper. The highest concentrations of chromium (VI) in the effluent cause a direct hazards to human and animals. Therefore, there is a need of an effective and affordable biotechnological solution for removal of chromium from electroplating effluent. Bacterial strains were isolated from electroplating effluent to find out higher tolerant isolate against chromate. The isolate was identified by 16S rDNA sequence analysis. Absorbed chromium level of bacterium was determined by inductively coupled plasma-atomic emission spectrometer (ICP-AES), atomic absorption spectrophotometer (AAS), scanning electron microscope (SEM), transmission electron microscope (TEM) and energy dispersive X-ray analysis (EDX). Removal of metals by bacterium from the electroplating effluent eventually led to the detoxification of effluent confirmed by MTT assay. Conformational changes of functional groups of bacterial cell surface were studied through Fourier transform infrared spectroscopy. The chromate tolerant isolate was identified as Bacillus cereus. Bacterium has potency to remove more than 75% of chromium as measured by ICP-AES and AAS. The study indicated the accumulation of chromium (VI) on bacterial cell surface which was confirmed by the SEM-EDX and TEM analysis. The biosorption of metals from the electroplating effluent eventually led to the detoxification of effluent. The increased survivability of Huh7 cells cultured with treated effluent also confirmed the detoxification as examined by MTT assay. Isolated strain B. cereus was able to remove and detoxify chromium (VI). It would be an efficient tool of the biotechnological approach in mitigating the heavy metal pollutants.

  6. Tetanus, Diphtheria (Td) Vaccine

    MedlinePlus

    ... Headache (about 1 person in 4) Tiredness (about 1 person in 4) Moderate Problems following Td vaccine:(Interfered with activities, but did not require medical attention)Fever over 102°F (rare) Severe Problems following ...

  7. Nickel extraction from nickel matte

    NASA Astrophysics Data System (ADS)

    Subagja, R.

    2018-01-01

    In present work, the results of research activities to make nickel metal from nickel matte are presented. The research activities were covering a) nickel matte characterization using Inductively Couple plasma (ICP), Electron Probe Micro Analyzer (EPMA) and X-Ray Diffraction (XRD), b) nickel matte dissolution process to dissolve nickel from nickel matte into the spent electrolyte solutions that contains hydrochloric acid, c) purification of nickel chloride leach solution by copper cementation process to remove copper using nickel matte, selective precipitation process to remove iron, solvent extraction using Tri normal octyl amine to separate cobalt from nickel chloride solutions and d) Nickel electro winning process to precipitate nickel into the cathode surface from purified nickel chloride solution by using direct current. The research activities created 99, 72 % pure nickel metal as the final product of the process.

  8. TdT activity in acute myeloid leukemias defined by monoclonal antibodies.

    PubMed

    San Miguel, J F; González, M; Cañizo, M C; Anta, J P; Portero, J A; López-Borrasca, A

    1986-09-01

    Blast cells from eight out of 71 patients diagnosed with acute myeloid leukemia (AML) by morphological, cytochemical, and immunological criteria showed TdT activity. Their distribution according to the FAB classification was one M1, one M2, one M4, two M5a, one M5b, one M6, and one undifferentiated case. The TdT+ AML cases did not show major clinical and hematological differences when compared with the classical TdT- AML patients. Other phenotypical aberrations in the expression of membrane antigens, apart from the presence of nuclear TdT, were not observed in these TdT+ cases after study with a large panel of monoclonal antibodies. A higher incidence of TdT+ cases was found among the monocytic variants of AML (M4 and M5)--four cases--than in the granulocytic variants (M1, M2, and M3)--2 cases. These TdT+ cases should be distinguished from mixed leukemias by double labeling techniques, assessing in the TdT+ AML the coexpression of TdT and myeloid markers in individual cells as shown in four of our cases.

  9. Long-range correction for tight-binding TD-DFT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Humeniuk, Alexander; Mitrić, Roland, E-mail: roland.mitric@uni-wuerzburg.de

    2015-10-07

    We present two improvements to the tight-binding approximation of time-dependent density functional theory (TD-DFTB): First, we add an exact Hartree-Fock exchange term, which is switched on at large distances, to the ground state Hamiltonian and similarly to the coupling matrix that enters the linear response equations for the calculation of excited electronic states. We show that the excitation energies of charge transfer states are improved relative to the standard approach without the long-range correction by testing the method on a set of molecules from the database in Peach et al. [J. Chem. Phys. 128, 044118 (2008)] which are known tomore » exhibit problematic charge transfer states. The degree of spatial overlap between occupied and virtual orbitals indicates where TD-DFTB and long-range corrected TD-DFTB (lc-TD-DFTB) can be expected to produce large errors. Second, we improve the calculation of oscillator strengths. The transition dipoles are obtained from Slater Koster files for the dipole matrix elements between valence orbitals. In particular, excitations localized on a single atom, which appear dark when using Mulliken transition charges, acquire a more realistic oscillator strength in this way. These extensions pave the way for using lc-TD-DFTB to describe the electronic structure of large chromophoric polymers, where uncorrected TD-DFTB fails to describe the high degree of conjugation and produces spurious low-lying charge transfer states.« less

  10. Accelerated Corrosion Results for Zinc/Nickel-Plated Automotive Parts Posttreated With Trivalent Chromate Rinse

    DTIC Science & Technology

    2010-09-01

    400 and 300 h in neutral salt spray. 5 Similarly plated samples post treated with trivalent chromium rinse lasted 450 and 200 h in neutral salt...Accelerated Corrosion Results for Zinc/Nickel-Plated Automotive Parts Posttreated With Trivalent Chromate Rinse by Chris E. Miller, Brian E...Posttreated With Trivalent Chromate Rinse Chris E. Miller and Brian E. Placzankis Weapons and Materials Research Directorate, ARL I. Carl Handsy

  11. Comparison of the effect of different surface treatments on the bond strength of different cements with nickel chromium metal alloy: An in vitro study

    PubMed Central

    Kapoor, Saumya; Balakrishnan, Dhanasekar

    2017-01-01

    Background For success of any indirect metal restoration, a strong bond between cement and the intaglio surface of metal is imperative. The aim of this study is to evaluate and compare the effect of different surface treatment on the tensile and shear bond strength of different cements with nickel–chromium alloy. Material and Methods 120 premolars were sectioned horizontally parallel to the occlusal surface to expose the dentin. Wax patterns were fabricated for individual tooth followed by casting them in nickel chromium alloy. 60 samples were tested for tensile bond strength, and the remaining 60 for shear bond strength. The samples were divided into three groups (of 20 samples each) as per the following surface treatment: oxidation only, oxidation and sandblasting, or oxidation, sandblasting followed by application of alloy primer. Each group was subdivided into 2 subgroups of 10 samples each, according to the bonding cement i.e RM-GIC and resin cement. Samples were subjected to thermocycling procedure followed by evaluation of bond strength. Results Two-way analyses of variance (ANOVA) was performed to compare the means of tensile and shear bond strength across type of surface treatment and cement, followed by post hoc parametric analysis. For all tests ‘p’ value of less than 0.05 was considered statistically significant. Conclusions The surface treatment of oxidation and sandblasting followed by application of alloy primer offered the maximum tensile and shear bond strength for both RM GIC and resin cement. Resin cement exhibited greater tensile and shear bond strength than RM-GIC for all the three surface treatment methods. Key words:Resin cement, resin modified glass ionomer cement, oxidation, sandblasting, alloy primer, tensile bond strength, shear bond strength, universal testing machine. PMID:28828160

  12. A review on nickel-free nitrogen containing austenitic stainless steels for biomedical applications.

    PubMed

    Talha, Mohd; Behera, C K; Sinha, O P

    2013-10-01

    The field of biomaterials has become a vital area, as these materials can enhance the quality and longevity of human life. Metallic materials are often used as biomaterials to replace structural components of the human body. Stainless steels, cobalt-chromium alloys, commercially pure titanium and its alloys are typical metallic biomaterials that are being used for implant devices. Stainless steels have been widely used as biomaterials because of their very low cost as compared to other metallic materials, good mechanical and corrosion resistant properties and adequate biocompatibility. However, the adverse effects of nickel ions being released into the human body have promoted the development of "nickel-free nitrogen containing austenitic stainless steels" for medical applications. Nitrogen not only replaces nickel for austenitic structure stability but also much improves steel properties. Here we review the harmful effects associated with nickel and emphatically the advantages of nitrogen in stainless steel, as well as the development of nickel-free nitrogen containing stainless steels for medical applications. By combining the benefits of stable austenitic structure, high strength, better corrosion and wear resistance and superior biocompatibility in comparison to the currently used austenitic stainless steel (e.g. 316L), the newly developed nickel-free high nitrogen austenitic stainless steel is a reliable substitute for the conventionally used medical stainless steels. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Proceedings of the sixth annual conference on fossil energy materials. Fossil Energy AR and TD Mateials Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cole, N.C.; Judkins, R.R.

    1992-07-01

    The Sixth Annual Conference on Fossil Energy Materials was held in Oak Ridge, Tennessee, on May 12--14, 1992. The meeting was sponsored by the US Department of Energy`s Office of Fossil Energy through the Advanced Research and Technology Development (AR&TD) Materials Program, and ASM International. The objective of the AR&TD Materials Program is to conduct research and development on materials for longer-term fossil energy applications as well as for generic needs of various fossil fuel technologies. The management of the Program has been decentralized to the DOE Field Office, Oak Ridge with Oak Ridge National Laboratory (ORNL) as the technicalmore » support contractor. The research is performed by staff members at ORNL and by a substantial number of researchers at other national laboratories, universities, and in private industry. The work is divided into the following categories: (1) ceramics, (2) development and corrosion resistance of iron aluminide, advanced austenitic and chromium-niobium alloys, and (3) technology assessment and technology transfer. This conference is held each year to review the work on all of the projects of the Program. The agenda for the meeting is given in Appendix A, and a list of attendees is presented in Appendix B. ASM International cosponsored the conference, for which we are especially grateful.« less

  14. Development of oxidation resistance in thoriated nickel-chromium base alloys

    NASA Technical Reports Server (NTRS)

    Seltzer, M. S.; Wilcox, B. A.; Jaffee, R. I.; Stringer, J.

    1971-01-01

    A pack process was developed which permits the introduction of nearly six weight percent aluminum into solid solution in the near-surface region of TDNiCr (Ni-20Cr-2ThO2. At this aluminum concentration an adherent alumina scale is produced on the alloy surface upon exposure to an environment of 1330 n/sq m (10 torr) or 101,000 n/sq m (760 torr) air at temperatures of 1093 C (2000 F) and 1204 C (2200 F). Room temperature mechanical properties of the aluminized alloys compare favorably with those of TDNiCr as received. While diffusivities for aluminum are a factor of three higher than those for chromium in TDNiCr or Ni-20Cr, the diffusion rates are similar for either of these elements in the thoriated or unthoriated alloy for a given temperature and grain size.

  15. Mach 1 oxidation of thoriated nickel chromium at 1204 C (2200 F)

    NASA Technical Reports Server (NTRS)

    Lowell, C. E.; Sanders, W. A.

    1971-01-01

    TD NiCr was exposed to a Mach 1, 1-atmosphere gas stream at 1204 C for times up to 50 hours. Weight change, metal thickness loss, X-ray diffraction, metallographic, and electron microprobe analyses were made. Neither surface preparation nor thermal cycling had an appreciable effect on the results. Initially, Cr2O3 formed and volatilized, allowing a rapid metal loss rate of 40 microns per hour. After about 1 hour the Cr2O3 broke down, resulting in an NiO overgrowth. The metal loss rate then slowed to 2.5 microns per hour and remained constant to 50 hours.

  16. Salivary levels of nickel, chromium, iron, and copper in patients treated with metal or esthetic fixed orthodontic appliances: A retrospective cohort study.

    PubMed

    Lages, Renata Bandeira; Bridi, Enrico Coser; Pérez, Carlos Alberto; Basting, Roberta Tarkany

    2017-03-01

    The purpose of this retrospective cohort study was to measure the salivary levels of nickel (Ni), chromium (Cr), iron (Fe) and copper (Cu) released from metal and esthetic fixed orthodontic appliances. Ninety patients were divided into three groups (n=30): control (those who had never undergone orthodontic treatment), metal appliance (stainless steel brackets and bands, and nitinol archwires) and esthetic appliance (polycarbonate brackets and tubes, and rhodium-coated nitinol archwires). Patients undergoing orthodontic treatment had used their appliances for periods between one and six months. Ni, Cr, Fe and Cu salivary concentrations were measured by the Total Reflection X-Ray Fluorescence technique. Kruskal-Wallis and Bonferroni-Dunn test showed that Ni (p=0.027) and Cr (p=0.040) concentrations were significantly higher for patients undergoing metallic orthodontic treatment than for the esthetic group. No significant difference regarding Ni and Cr (p=0.447) concentrations were observed between the metal and the control groups (p=0.464 and p=0.447, respectively) or between the esthetic and the control groups (p=0.698 and p=0.912, respectively). Ni and Cr concentrations were significantly influenced by the type of appliance used. Fe and Cu concentrations were not affected by the type or use of orthodontic appliances. Copyright © 2016 Elsevier GmbH. All rights reserved.

  17. Biofouling of Cr-Nickel Spray Coated Films on Steel Surfaces

    NASA Astrophysics Data System (ADS)

    Yoshida, Kento; Kanematsu, Hideyuki; Kuroda, Daisuke; Ikigai, Hajime; Kogo, Takeshi; Yokoyama, Seiji

    2012-03-01

    Nowadays, corrosion of metals brings us serious economic loss and it often reaches several percentage of GNP. Particularly the marine corrosion was serious and the counter measure was very hard to be established, since the number of factors is huge and complicated. One of the complicated factors in marine corrosion is biofouling. Biofouling was classified into two main categories, microfouling and macrofouling. The former is composed of biofilm formation mainly. Marine bacteria are attached to material surfaces, seeking for nutrition in oligotrophic environment and they excrete polysaccharide to form biofilm on metal surfaces. Then larger living matters are attached on the biofilms to develop biofouling on metal surfaces, which often lead loss and failures of metals in marine environments. From the viewpoint of corrosion protection and maintenance of marine structures, biofouling should be mitigated as much as possible. In this study, we applied spray coating to steels and investigated if chromium-nickel spray coating could mitigate the biofouling, being compared with the conventional aluminium-zinc spray coating in marine environments. The specimens used for this investigation are aluminium, zinc, aluminium-zinc, stacked chromium/nickel and those films were formed on carbon steel (JIS SS400). And the pores formed by spray coating were sealed by a commercial reagent for some specimens. All of those specimens were immersed into sea water located at Marina Kawage (854-3, Chisato, Tsu, Mie Prefecture) in Ise Bay for two weeks. The depth of the specimen was two meter from sea water surface and the distance was always kept constant, since they were suspended from the floating pier. The temperature in sea water changed from 10 to 15 degrees Celsius during the immersion test. The biofouling behavior was investigated by low vacuum SEM (Hitachi Miniscope TM1000) and X-ray fluorescent analysis. When the spray coated specimens with and without sealing agents were compared

  18. Therapeutic review: is ascorbic acid of value in chromium poisoning and chromium dermatitis?

    PubMed

    Bradberry, S M; Vale, J A

    1999-01-01

    Repeated topical exposure to chromium(VI) may cause an allergic contact dermatitis or the formation of chrome ulcers. Systemic toxicity may occur following the ingestion of a chromium(VI) salt, from chromium(VI)-induced skin burns, or from inhalation of chromium(VI) occurring occupationally. Soluble chromium(VI) salts are usually absorbed more easily and cross cell membranes more readily than trivalent chromium salts, and, therefore chromium(VI) is more toxic than chromium(III). In experimental studies, endogenous ascorbic acid in rat lung, liver, and kidney and human plasma, effectively reduces chromium(VI) to chromium(III). The administration of exogenous ascorbic acid has been advocated therefore in the treatment of systemic chromium poisoning and chromium dermatitis to enhance the extracellular reduction of chromium(VI) to the less bioavailable chromium(III). In vitro experiments confirm that the addition of ascorbic acid to plasma containing chromium(VI) leads to a dose-dependent reduction of chromium(VI) to chromium(III). In animal studies, parenteral ascorbic acid 0.5-5 g/kg significantly reduced chromium-induced nephrotoxicity when administered 30 minutes before parenteral sodium dichromate and up to 1 hour after parenteral sodium chromate dosing. Parenteral ascorbic acid 0.5-5 g/kg also reduced mortality when given orally up to 2 hours after oral potassium dichromate dosing. However, the administration of parenteral ascorbic acid more than 2 hours after parenteral chromate in these experimental studies did not protect against renal damage, and parenteral ascorbic acid given 3 hours postparenteral chromate increased toxicity. In addition, there is no confirmed clinical evidence that the administration of ascorbic acid lessens morbidity or mortality in systemic chromium poisoning. A possible reason for the lack of benefit of ascorbic acid when administration is delayed, is that chromium(VI) cellular uptake has occurred prior to ascorbic acid administration

  19. Discontinuous precipitation in a nickel-free high nitrogen austenitic stainless steel on solution nitriding

    NASA Astrophysics Data System (ADS)

    Mohammadzadeh, Roghayeh; Akbari, Alireza; Grumsen, Flemming B.; Somers, Marcel A. J.

    2017-10-01

    Chromium-rich nitride precipitates in production of nickel-free austenitic stainless steel plates via pressurised solution nitriding of Fe-22.7Cr-2.4Mo ferritic stainless steel at 1473 K (1200 °C) under a nitrogen gas atmosphere was investigated. The microstructure, chemical and phase composition, morphology and crystallographic orientation between the resulted austenite and precipitates were investigated using optical microscopy, X-ray Diffraction (XRD), Scanning and Transmission Electron Microscopy (TEM) and Electron Back Scatter Diffraction (EBSD). On prolonged nitriding, Chromium-rich nitride precipitates were formed firstly close to the surface and later throughout the sample with austenitic structure. Chromium-rich nitride precipitates with a rod or strip-like morphology was developed by a discontinuous cellular precipitation mechanism. STEM-EDS analysis demonstrated partitioning of metallic elements between austenite and nitrides, with chromium contents of about 80 wt.% in the precipitates. XRD analysis indicated that the Chromium-rich nitride precipitates are hexagonal (Cr, Mo)2N. Based on the TEM studies, (Cr, Mo)2N precipitates presented a (1 1 1)γ//(0 0 2)(Cr, Mo)2N, ?γ//?(Cr, Mo)2N orientation relationship with respect to the austenite matrix. EBSD studies revealed that the austenite in the regions that have transformed into austenite and (Cr, Mo)2N have no orientation relation to the untransformed austenite.

  20. Exact PsTd invariant and PsTd symmetric breaking solutions, symmetry reductions and Bäcklund transformations for an AB-KdV system

    NASA Astrophysics Data System (ADS)

    Jia, Man; Lou, Sen Yue

    2018-05-01

    In natural and social science, many events happened at different space-times may be closely correlated. Two events, A (Alice) and B (Bob) are defined as correlated if one event is determined by another, say, B = f ˆ A for suitable f ˆ operators. A nonlocal AB-KdV system with shifted-parity (Ps, parity with a shift), delayed time reversal (Td, time reversal with a delay) symmetry where B =Ps ˆ Td ˆ A is constructed directly from the normal KdV equation to describe two-area physical event. The exact solutions of the AB-KdV system, including PsTd invariant and PsTd symmetric breaking solutions are shown by different methods. The PsTd invariant solution show that the event happened at A will happen also at B. These solutions, such as single soliton solutions, infinitely many singular soliton solutions, soliton-cnoidal wave interaction solutions, and symmetry reduction solutions etc., show the AB-KdV system possesses rich structures. Also, a special Bäcklund transformation related to residual symmetry is presented via the localization of the residual symmetry to find interaction solutions between the solitons and other types of the AB-KdV system.

  1. Tree Data (TD)

    Treesearch

    Robert E. Keane

    2006-01-01

    The Tree Data (TD) methods are used to sample individual live and dead trees on a fixed-area plot to estimate tree density, size, and age class distributions before and after fire in order to assess tree survival and mortality rates. This method can also be used to sample individual shrubs if they are over 4.5 ft tall. When trees are larger than the user-specified...

  2. In situ removal of carbon contamination from a chromium-coated mirror: ideal optics to suppress higher-order harmonics in the carbon K-edge region.

    PubMed

    Toyoshima, Akio; Kikuchi, Takashi; Tanaka, Hirokazu; Mase, Kazuhiko; Amemiya, Kenta

    2015-11-01

    Carbon-free chromium-coated optics are ideal in the carbon K-edge region (280-330 eV) because the reflectivity of first-order light is larger than that of gold-coated optics while the second-order harmonics (560-660 eV) are significantly suppressed by chromium L-edge and oxygen K-edge absorption. Here, chromium-, gold- and nickel-coated mirrors have been adopted in the vacuum ultraviolet and soft X-ray branch beamline BL-13B at the Photon Factory in Tsukuba, Japan. Carbon contamination on the chromium-coated mirror was almost completely removed by exposure to oxygen at a pressure of 8 × 10(-2) Pa for 1 h under irradiation of non-monochromated synchrotron radiation. The pressure in the chamber recovered to the order of 10(-7) Pa within a few hours. The reflectivity of the chromium-coated mirror of the second-order harmonics in the carbon K-edge region (560-660 eV) was found to be a factor of 0.1-0.48 smaller than that of the gold-coated mirror.

  3. Development of Sediment Quality Values for Puget Sound. Volume 1.

    DTIC Science & Technology

    1986-09-01

    62 cadmium CHROMIUM,63 chromium COPPER ,64 copper IRON ,65 iron LEAD ,66 lead MANGANES ,67 manganese NICKEL ,68 nickel SELENIUM,69 selenium SILVER ,70...BERYLLIU beryllium 67. CADMIUM cadmium 68. CHROMIUM chromium 69. COPPER copper 70. IRON iron 71. LEAD lead 72. MANGANES manganese 73. NICKEL nickel 74...they can also be strongly influenced by iron and manganese oxide and hydrous oxide surfaces (these phases can scavenge metals under oxidizing

  4. 40 CFR 471.35 - Pretreatment standards for new sources (PSNS).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (pounds per million off-pounds) of nickel-cobalt rolled with emulsions Chromium 0.063 0.026 Nickel 0.094 0... nickel-cobalt rolled with water Chromium 0.028 0.012 Nickel 0.042 0.028 Fluoride 4.49 1.99 (d) Tube... monthly average mg/off-kg (pounds per million off-pounds) of nickel-cobalt drawn with emulsions Chromium 0...

  5. 40 CFR 471.32 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (pounds per million off-pounds) of nickel-cobalt rolled with emulsions Chromium 0.063 0.026 Nickel 0.094 0... nickel-cobalt rolled with water Chromium 0.028 0.011 Nickel 0.042 0.028 Fluoride 4.49 1.99 (d) Tube... monthly average mg/off-kg (pounds per million off-pounds) of nickel-cobalt drawn with emulsions Chromium 0...

  6. Do trace metals (chromium, copper, and nickel) influence toxicity of diesel fuel for free-living marine nematodes?

    PubMed

    Hedfi, Amor; Boufahja, Fehmi; Ben Ali, Manel; Aïssa, Patricia; Mahmoudi, Ezzeddine; Beyrem, Hamouda

    2013-06-01

    The objective of this study was to test the hypotheses that (1) free-living marine nematodes respond in a differential way to diesel fuel if it is combined with three trace metals (chromium, copper, and nickel) used as smoke suppressants and that (2) the magnitude of toxicity of diesel fuel differs according to the level of trace metal mixture added. Nematodes from Sidi Salem beach (Tunisia) were subjected separately for 30 days to three doses of diesel fuel and three others of a trace metals mixture. Simultaneously, low-dose diesel was combined with three amounts of a trace metal mixture. Results from univariate and multivariate methods of data evaluation generally support our initial hypothesis that nematode assemblages exhibit various characteristic changes when exposed to different types of disturbances; the low dose of diesel fuel, discernibly non-toxic alone, became toxic when trace metals were added. For all types of treatments, biological disturbance caused severe specific changes in assemblage structure. For diesel fuel-treated microcosms, Marylynnia bellula and Chromaspirinia pontica were the best positive indicative species; their remarkable presence in given ecosystem may predict unsafe seafood. The powerful toxicity of the combination between diesel fuel and trace metals was expressed with only negative bioindicators, namely Trichotheristus mirabilis, Pomponema multipapillatum, Ditlevsenella murmanica, Desmodora longiseta, and Bathylaimus capacosus. Assemblages with high abundances of these species should be an index of healthy seafood. When nematodes were exposed to only trace metals, their response looks special with a distinction of a different list of indicative species; the high presence of seven species (T. mirabilis, P. multipapillatum, Leptonemella aphanothecae, D. murmanica, Viscosia cobbi, Gammanema conicauda, and Viscosia glabra) could indicate a good quality of seafood and that of another species (Oncholaimellus mediterraneus) appeared an

  7. Weathering and transport of chromium and nickel from serpentinite in the Coast Range ophiolite to the Sacramento Valley, California, USA

    USGS Publications Warehouse

    Morrison, Jean M.; Goldhaber, Martin B.; Mills, Christopher T.; Breit, George N.; Hooper, Robert L.; Holloway, JoAnn M.; Diehl, Sharon F.; Ranville, James F.

    2015-01-01

    A soil geochemical study in northern California was done to investigate the role that weathering and transport play in the regional distribution and mobility of geogenic Cr and Ni, which are both potentially toxic and carcinogenic. These elements are enriched in ultramafic rocks (primarily serpentinite) and the soils derived from them (1700–10,000 mg Cr per kg soil and 1300–3900 mg Ni per kg soil) in the Coast Range ophiolite. Chromium and Ni have been transported eastward from the Coast Range into the western Sacramento Valley and as a result, valley soil is enriched in Cr (80–1420 mg kg−1) and Ni (65–224 mg kg−1) compared to median values of U.S. soils of 50 and 15 mg kg−1, respectively. Nickel in ultramafic source rocks and soils is present in serpentine minerals (lizardite, antigorite, and chrysotile) and is more easily weathered compared to Cr, which primarily resides in highly refractory chromite ([Mg,Fe2+][Cr3+,Al,Fe3+]2O4). Although the majority of Cr and Ni in soils are in refractory chromite and serpentine minerals, the etching and dissolution of these minerals, presence of Cr- and Ni-enriched clay minerals and development of nanocrystalline Fe (hydr)oxides is evidence that a significant fractions of these elements have been transferred to potentially more labile phases.

  8. Uplink scheduling and adjacent-channel coupling loss analysis for TD-LTE deployment.

    PubMed

    Yeo, Woon-Young; Moon, Sung Ho; Kim, Jae-Hoon

    2014-01-01

    TD-LTE, one of the two duplexing modes in LTE, operates in unpaired spectrum and has the advantages of TDD-based technologies. It is expected that TD-LTE will be more rapidly deployed in near future and most of WiMax operators will upgrade their networks to TD-LTE gradually. Before completely upgrading to TD-LTE, WiMax may coexist with TD-LTE in an adjacent frequency band. In addition, multiple TD-LTE operators may deploy their networks in adjacent bands. When more than one TDD network operates in adjacent frequency bands, severe interference may happen due to adjacent channel interference (ACI) and unsynchronized operations. In this paper, coexistence issues between TD-LTE and other systems are analyzed and coexistence requirements are provided. This paper has three research objectives. First, frame synchronization between TD-LTE and WiMax is discussed by investigating possible combinations of TD-LTE and WiMax configurations. Second, an uplink scheduling algorithm is proposed to utilize a leakage pattern of ACI in synchronized operations. Third, minimum requirements for coexistence in unsynchronized operations are analyzed by introducing a concept of adjacent-channel coupling loss. From the analysis and simulation results, we can see that coexistence of TD-LTE with other TDD systems is feasible if the two networks are synchronized. For the unsynchronized case, some special cell-site engineering techniques may be required to reduce the ACI.

  9. Uplink Scheduling and Adjacent-Channel Coupling Loss Analysis for TD-LTE Deployment

    PubMed Central

    Yeo, Woon-Young; Moon, Sung Ho

    2014-01-01

    TD-LTE, one of the two duplexing modes in LTE, operates in unpaired spectrum and has the advantages of TDD-based technologies. It is expected that TD-LTE will be more rapidly deployed in near future and most of WiMax operators will upgrade their networks to TD-LTE gradually. Before completely upgrading to TD-LTE, WiMax may coexist with TD-LTE in an adjacent frequency band. In addition, multiple TD-LTE operators may deploy their networks in adjacent bands. When more than one TDD network operates in adjacent frequency bands, severe interference may happen due to adjacent channel interference (ACI) and unsynchronized operations. In this paper, coexistence issues between TD-LTE and other systems are analyzed and coexistence requirements are provided. This paper has three research objectives. First, frame synchronization between TD-LTE and WiMax is discussed by investigating possible combinations of TD-LTE and WiMax configurations. Second, an uplink scheduling algorithm is proposed to utilize a leakage pattern of ACI in synchronized operations. Third, minimum requirements for coexistence in unsynchronized operations are analyzed by introducing a concept of adjacent-channel coupling loss. From the analysis and simulation results, we can see that coexistence of TD-LTE with other TDD systems is feasible if the two networks are synchronized. For the unsynchronized case, some special cell-site engineering techniques may be required to reduce the ACI. PMID:24707214

  10. A G protein-coupled receptor (GPCR) in red: live cell imaging of the kappa opioid receptor-tdTomato fusion protein (KOPR-tdT) in neuronal cells

    PubMed Central

    Huang, Peng; Chiu, Yi-Ting; Chen, Chongguang; Wang, Yujun; Liu-Chen, Lee-Yuan

    2013-01-01

    Introduction In contrast to green fluorescent protein and variants (GFPs), red fluorescent proteins (RFPs) have rarely been employed for generation of GPCR fusion proteins, likely because of formation of aggregates and cell toxicity of some RFPs. Among all the RFPs available, tdTomato (tdT), one of the non-aggregating RFP, has the highest brightness score (about 3 times that of eGFP) and unsurpassed photostability. Methods We fused tdT to the KOPR C-terminus. The KOPR-tdT cDNA construct was transfected into Neuro2A mouse neuroblastoma cell line (Neuro2A cells) and rat cortical primary neurons for characterization of pharmacological properties and imaging studies on KOPR trafficking. Results KOPR-tdT retained KOPR properties (cell surface expression, ligand binding, agonist-induced signaling and internalization) when expressed in Neuro2A cells and rat primary cortical neurons. Live cell imaging of KOPR-tdT enables visualization of time course of agonist-induced internalization of KOPR in real time for 60 min, without photobleaching and apparent cell toxicity. U50,488H-induced KOPR internalization occurred as early as 4 min and plateaued at about 30 min. A unique pattern of internalized KOPR in processes of primary neurons was induced by U50,488H. Discussion tdT is an alternative to, or even a better tool than, GFPs for fusing to GPCR for trafficking studies, because tdT has higher brightness and thus better resolution and less photobleaching problems due to reduced laser power used. It also has advantages associated with its longer-wavelength emission including spectral separation from autofluorescence and GFPs, reduced cell toxicity the laser may impose, and greater tissue penetration. These advantages of tdT over GPFs may be critical for live cell imaging studies of GPCRs in vitro and for studying GPCRs in vivo because of their low abundance. PMID:23856011

  11. Occupational asthma due to chrome and nickel electroplating

    PubMed Central

    Bright, P.; Burge, P. S.; O'Hickey, S. P.; Gannon, P. F.; Robertson, A. S.; Boran, A.

    1997-01-01

    BACKGROUND: Exposure to chromium during electroplating is a recognised though poorly characterised cause of occupational asthma. The first series of such patients referred to a specialist occupational lung disease clinic is reported. METHODS: The diagnosis of occupational asthma was made from a history of asthma with rest day improvement and confirmed by specific bronchial provocation testing with potassium dichromate and nickel chloride. RESULTS: Seven workers had been exposed to chrome and nickel fumes from electroplating for eight months to six years before asthma developed. One subject, although exposed for 11 years without symptoms, developed asthma after a single severe exposure during a ventilation failure. This was the only subject who had never smoked. The diagnosis was confirmed by specific bronchial challenges. Two workers had isolated immediate reactions, one a late asthmatic reaction, and four a dual response following exposure to nebulised potassium dichromate at 1-10 mg/ml. Two of the four subjects were also challenged with nebulised nickel chloride at 0.1-10 mg/ml. Two showed isolated late asthmatic reactions, in one at 0.1 mg/ml, where nickel was probably the primary sensitising agent. Four workers carried out two hourly measurements of peak expiratory flow over days at and away from work. All were scored as having occupational asthma using OASYS-2. Breathing zone air monitoring was carried out in 60 workers from four decorative and two hard chrome plating shops from workers with similar jobs to those sensitised. No measurement exceeded the current occupational exposure standard for chromate or nickel, the mean levels of chromate exposure for jobs similar to those of the affected workers were 9-15 micrograms/m3. CONCLUSION: Chrome used in electroplating is a potential cause of occupational asthma. Sensitivity to chrome in electroplaters may occur in situations where exposure levels are likely to be within the current exposure standards. There may

  12. Two-phase chromium-niobium alloys exhibiting improved mechanical properties at high temperatures

    DOEpatents

    Liu, Chain T.; Takeyama, Masao

    1994-01-01

    The specification discloses chromium-niobium alloys which exhibit improved mechanical properties at high temperatures in the range of 1250.degree. C. and improved room temperature ductility. The alloys contain a Cr.sub.2 Nb-rich intermetallic phase and a Cr-rich phase with an overall niobium concentration in the range of from about 5 to about 18 at. %. The high temperature strength is substantially greater than that of state of the art nickel-based superalloys for enhanced high temperature service. Further improvements in the properties of the compositions are obtained by alloying with rhenium and aluminum; and additional rare-earth and other elements.

  13. Corrosion Behavior of High Nitrogen Nickel-Free Fe-16Cr-Mn-Mo-N Stainless Steels

    NASA Astrophysics Data System (ADS)

    Chao, K. L.; Liao, H. Y.; Shyue, J. J.; Lian, S. S.

    2014-04-01

    The purpose of the current study is to develop austenitic nickel-free stainless steels with lower chromium content and higher manganese and nitrogen contents. In order to prevent nickel-induced skin allergy, cobalt, manganese, and nitrogen were used to substitute nickel in the designed steel. Our results demonstrated that manganese content greater than 14 wt pct results in a structure that is in full austenite phase. The manganese content appears to increase the solubility of nitrogen; however, a lower corrosion potential was found in steel with high manganese content. Molybdenum appears to be able to increase the pitting potential. The effects of Cr, Mn, Mo, and N on corrosion behavior of Fe-16Cr-2Co-Mn-Mo-N high nitrogen stainless steels were evaluated with potentiodynamic tests and XPS surface analysis. The results reveal that anodic current and pits formation of the Fe-16Cr-2Co-Mn-Mo-N high nitrogen stainless steels were smaller than those of lower manganese and nitrogen content stainless steel.

  14. The Efficiency of Delone Coverings of the Canonical Tilings T^*(A4) and T}(*(D_6)) -> T^*(D6)

    NASA Astrophysics Data System (ADS)

    Papadopolos, Zorka; Kasner, Gerald

    This chapter is devoted to the coverings of the two quasiperiodic canonical tilings T^*(A4) and T}(*(D_6)) equiv {cal T}(*(2F)) -> T^*(D6) T^*(2F), obtained by projection from the root lattices A4 and D6, respectively. In the first major part of this chapter, in Sect. 5.2, we shall introduce a Delone covering C^sT^*(A4) of the 2-dimensional decagonal tiling T^*(A4). In the second major part of this chapter, Sect. 5.3, we summarize the results related to the Delone covering of the icosahedral tiling T}(*(D_6)) -> T^*(D6), T}(*(D_6)}) -> CT^*(D6) and determine the zero-, single-, and double- deckings and the resulting thickness of the covering. In the conclusions section, we give some suggestions as to how the definition of the Delone covering might be changed in order to reach some real (full) covering of the icosahedral tiling T}(*(D_6)) -> T^*(D6). In Section 5.2 the definition of the Delone covering is also changed in order to avoid an unnecessary large thickness of the covering.

  15. Many-Body Perturbation Theory (MBPT) and Time-Dependent Density-Functional Theory (TD-DFT): MBPT Insights About What Is Missing In, and Corrections To, the TD-DFT Adiabatic Approximation.

    PubMed

    Casida, Mark E; Huix-Rotllant, Miquel

    2016-01-01

    In their famous paper, Kohn and Sham formulated a formally exact density-functional theory (DFT) for the ground-state energy and density of a system of N interacting electrons, albeit limited at the time by certain troubling representability questions. As no practical exact form of the exchange-correlation (xc) energy functional was known, the xc-functional had to be approximated, ideally by a local or semilocal functional. Nowadays, however, the realization that Nature is not always so nearsighted has driven us up Perdew's Jacob's ladder to find increasingly nonlocal density/wavefunction hybrid functionals. Time-dependent (TD-) DFT is a younger development which allows DFT concepts to be used to describe the temporal evolution of the density in the presence of a perturbing field. Linear response (LR) theory then allows spectra and other information about excited states to be extracted from TD-DFT. Once again the exact TD-DFT xc-functional must be approximated in practical calculations and this has historically been done using the TD-DFT adiabatic approximation (AA) which is to TD-DFT very similar to what the local density approximation (LDA) is to conventional ground-state DFT. Although some of the recent advances in TD-DFT focus on what can be done within the AA, others explore ways around the AA. After giving an overview of DFT, TD-DFT, and LR-TD-DFT, this chapter focuses on many-body corrections to LR-TD-DFT as one way to build hybrid density-functional/wavefunction methodology for incorporating aspects of nonlocality in time not present in the AA.

  16. Urinary levels of nickel and chromium associated with dental restoration by nickel–chromium based alloys

    PubMed Central

    Chen, Bo; Xia, Gang; Cao, Xin-Ming; Wang, Jue; Xu, Bi-Yao; Huang, Pu; Chen, Yue; Jiang, Qing-Wu

    2013-01-01

    This paper aims to investigate if the dental restoration of nickel–chromium based alloy (Ni–Cr) leads to the enhanced excretions of Ni and Cr in urine. Seven hundred and ninety-five patients in a dental hospital had single or multiple Ni–Cr alloy restoration recently and 198 controls were recruited to collect information on dental restoration by questionnaire and clinical examination. Urinary concentrations of Ni and Cr from each subject were measure by graphite furnace atomic absorption spectrometry. Compared to the control group, the urinary level of Ni was significantly higher in the patient group of <1 month of the restoration duration, among which higher Ni excretions were found in those with either a higher number of teeth replaced by dental alloys or a higher index of metal crown not covered with the porcelain. Urinary levels of Cr were significantly higher in the three patient groups of <1, 1 to <3 and 3 to <6 months, especially in those with a higher metal crown exposure index. Linear curve estimations showed better relationships between urinary Ni and Cr in patients within 6-month groups. Our data suggested significant increased excretions of urinary Ni and Cr after dental restoration. Potential short- and long-term effects of Ni–Cr alloy restoration need to be investigated. PMID:23579466

  17. 40 CFR 471.34 - Pretreatment standards for existing sources (PSES).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... emulsions Chromium 0.063 0.026 Nickel 0.094 0.063 Fluoride 10.1 4.49 (c) Rolling contact cooling water... (pounds per million off-pounds) of nickel-cobalt rolled with water Chromium 0.028 0.011 Nickel 0.042 0.028... drawn with emulsions Chromium 0.036 0.014 Nickel 0.053 0.036 Fluoride 5.68 2.52 (g) Extrusion spent...

  18. Functional heterogeneity of memory B lymphocytes: in vivo analysis of TD-primed B cells responsive to secondary stimulation with TD and TI antigens.

    PubMed

    Rennick, D M; Morrow, P R; Benjamini, E

    1983-08-01

    The functional heterogeneity of memory B cells induced by a single determinant, consisting of a decapeptide representing amino acid residues 103-112 of tobacco mosaic virus protein (TMVP), was analyzed. Decapeptide specific antibodies were elicited in mice adoptively transferred with TMVP-immune spleen cells when challenged with TMVP, decapeptide conjugated to succinylated human gamma-globulin (SHGG), or decapeptide conjugated to Brucella abortus (BA). Whereas secondary stimulation by either TMVP or decapeptide-SHGG was dependent on appropriately primed T cells, stimulation by decapeptide-BA was independent of conventional T cell help. Furthermore, memory B cells responsive to TMVP (TD), decapeptide-SHGG (TD), or decapeptide-BA (TI. 1 prototype) were shown to consist of overlapping populations because adoptive recipients of TMVP-primed cells challenged simultaneously with TD and TI decapeptide antigens did not result in a higher antibody response than that elicited by one of the TD antigens injected alone. However, decapeptide-BA consistently induced a smaller antidecapeptide response than either TMVP or decapeptide-SHGG. This suggested that only a fraction of the memory B cell population which was activated by the original priming antigen (thymus-dependent) was also responsive to secondary in vivo stimulation by the priming hapten conjugated to Brucella abortus. Detailed analyses of the antibodies induced in the recipients of TMVP-immune spleen cells after secondary challenge with either TMVP, decapeptide-SHGG, or decapeptide-BA failed to distinguish between the responsive memory B cells; the antidecapeptide antibodies induced by all three immunogens shared the same fine specificities and immunoglobulin isotype composition. These data are viewed as further evidence that subsets of TD-primed B cells, which may display differential sensitivity to cross-stimulation with TD and TI forms of the antigen, represent distinct stages of memory B cell maturation within a

  19. Describing excited state relaxation and localization in TiO 2 nanoparticles using TD-DFT

    DOE PAGES

    Berardo, Enrico; Hu, Han -Shi; van Dam, Hubertus J. J.; ...

    2014-02-26

    We have investigated the description of excited state relaxation in naked and hydrated TiO 2 nanoparticles using Time-Dependent Density Functional Theory (TD-DFT) with three common hybrid exchange-correlation (XC) potentials; B3LYP, CAM-B3LYP and BHLYP. Use of TD-CAM-B3LYP and TD-BHLYP yields qualitatively similar results for all structures, which are also consistent with predictions of coupled cluster theory for small particles. TD-B3LYP, in contrast, is found to make rather different predictions; including apparent conical intersections for certain particles that are not observed with TD-CAM-B3LYP nor with TD-BHLYP. In line with our previous observations for vertical excitations, the issue with TD-B3LYP appears to bemore » the inherent tendency of TD-B3LYP, and other XC potentials with no or a low percentage of Hartree-Fock Like Exchange, to spuriously stabilize the energy of charge-transfer (CT) states. Even in the case of hydrated particles, for which vertical excitations are generally well described with all XC potentials, the use of TD-B3LYP appears to result in CT-problems for certain particles. We hypothesize that the spurious stabilization of CT-states by TD-B3LYP even may drive the excited state optimizations to different excited state geometries than those obtained using TD-CAM-B3LYP or TD-BHLYP. In conclusion, focusing on the TD-CAM-B3LYP and TD-BHLYP results, excited state relaxation in naked and hydrated TiO 2 nanoparticles is predicted to be associated with a large Stokes’ shift.« less

  20. Describing excited state relaxation and localization in TiO 2 nanoparticles using TD-DFT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berardo, Enrico; Hu, Han -Shi; van Dam, Hubertus J. J.

    We have investigated the description of excited state relaxation in naked and hydrated TiO 2 nanoparticles using Time-Dependent Density Functional Theory (TD-DFT) with three common hybrid exchange-correlation (XC) potentials; B3LYP, CAM-B3LYP and BHLYP. Use of TD-CAM-B3LYP and TD-BHLYP yields qualitatively similar results for all structures, which are also consistent with predictions of coupled cluster theory for small particles. TD-B3LYP, in contrast, is found to make rather different predictions; including apparent conical intersections for certain particles that are not observed with TD-CAM-B3LYP nor with TD-BHLYP. In line with our previous observations for vertical excitations, the issue with TD-B3LYP appears to bemore » the inherent tendency of TD-B3LYP, and other XC potentials with no or a low percentage of Hartree-Fock Like Exchange, to spuriously stabilize the energy of charge-transfer (CT) states. Even in the case of hydrated particles, for which vertical excitations are generally well described with all XC potentials, the use of TD-B3LYP appears to result in CT-problems for certain particles. We hypothesize that the spurious stabilization of CT-states by TD-B3LYP even may drive the excited state optimizations to different excited state geometries than those obtained using TD-CAM-B3LYP or TD-BHLYP. In conclusion, focusing on the TD-CAM-B3LYP and TD-BHLYP results, excited state relaxation in naked and hydrated TiO 2 nanoparticles is predicted to be associated with a large Stokes’ shift.« less

  1. Development of low-chromium, chromium-tungsten steels for fusion

    NASA Astrophysics Data System (ADS)

    Klueh, R. L.; Alexander, D. J.; Kenik, E. A.

    1995-12-01

    High-chromium (9-12% Cr) CrMo and CrW ferritic steels are favored as candidates for fusion applications. In early work to develop reduced-activation steels, an Fe2.25Cr2W-0.25V-O.1C steel (designated 2.25Cr-2WV) had better strength than an Fe9Cr2W-0.25V-0.07Tra-0.1C (9Cr-2WVTa) steel (compositions are in weight percent). However, the 2.25Cr-2WV had poor impact properties, as determined by the ductile-brittle transition temperature and upper-shelf energy of subsize Charpy impact specimens. Because low-chromium steels have some advantages over high-chromium steels, a program to develop low-chromium steels is in progress. Microstructural analysis indicated that the reason for the inferior impact toughness of the 2.25Cr-2WV was the granular bainite obtained when the steel was normalized. Properties can be improved by developing an acicular bainite microstructure by increasing the cooling rate after austenitization. Alternatively, acicular bainite can be promoted by increasing the hardenability. Hardenability was changed by adding small amounts of boron and additional chromium to the 2.250-2WV composition. A combination of B, Cr, and Ta additions resulted in low-chromium reduced-activation steels with mechanical properties comparable to those of 9Cr-2WVTa.

  2. 40 CFR 415.176 - Pretreatment standards for new sources (PSNS).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... liter Chromium (T) 1.0 0.50 Hexavalent Chromium 0.11 0.060 Nickel (T) 0.80 0.40 In cases where POTWs... an alternate: The limitations for Chromium (T), Hexavalent Chromium, and Nickel (T) are the same as...

  3. 40 CFR 415.176 - Pretreatment standards for new sources (PSNS).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... liter Chromium (T) 1.0 0.50 Hexavalent Chromium 0.11 0.060 Nickel (T) 0.80 0.40 In cases where POTWs... an alternate: The limitations for Chromium (T), Hexavalent Chromium, and Nickel (T) are the same as...

  4. 40 CFR 415.176 - Pretreatment standards for new sources (PSNS).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... liter Chromium (T) 1.0 0.50 Hexavalent Chromium 0.11 0.060 Nickel (T) 0.80 0.40 In cases where POTWs... an alternate: The limitations for Chromium (T), Hexavalent Chromium, and Nickel (T) are the same as...

  5. 40 CFR 415.176 - Pretreatment standards for new sources (PSNS).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... liter Chromium (T) 1.0 0.50 Hexavalent Chromium 0.11 0.060 Nickel (T) 0.80 0.40 In cases where POTWs... an alternate: The limitations for Chromium (T), Hexavalent Chromium, and Nickel (T) are the same as...

  6. 40 CFR 503.43 - Pollutant limits.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... accordance with § 503.43(e). (d) Pollutant limit—arsenic, cadmium, chromium, and nickel. (1) The average daily concentration for arsenic, cadmium, chromium, and nickel in sewage sludge fed to a sewage sludge... = Average daily concentration of arsenic, cadmium, chromium, or nickel in sewage sludge. CE = Sewage sludge...

  7. A novel thiazolidinedione derivative TD118 showing selective algicidal effects for red tide control.

    PubMed

    Wu, Ying; Lee, Yew; Jung, Seul-Gi; Kim, Minju; Eom, Chi-Yong; Kim, Si Wouk; Cho, Hoon; Jin, Eonseon

    2014-05-01

    Thiazolidinedione (TD) derivatives have been found to have an algicidal effect on harmful algal bloom microalgae. In this study, 75 TD derivatives were synthesized and analyzed for algicidal activity. Among these synthetic TDs, 18 TD derivatives showed specific algicidal activity on two strains belonging to the classes Raphidophyceae (Chattonella marina and Heterosigma akashiwo) and Dinophyceae (Cochlodinium polykrikoides). Two strains belonging to Bacillariophyceae (Navicula pelliculosa and Phaeodactylum EPV), one strain belonging to Dinophyceae (Amphidinium sp.), and a Eustigmatophycean microalga (Nannochloropsis oculata) showed less sensitivity to the TD derivatives than the other two phyla. The most reactive TD derivative, compound 2 (TD118), was selected and tested for morphological and physiological changes. TD118 effectively damaged the cell membrane of C. marina, H. akashiwo and C. polykrikoides. The O₂ evolution and photosystem II efficiency (F(v)/F(m)) of C. marina, H. akashiwo and C. polykrikoides were also severely reduced by TD118 treatment. Amphidinium sp., N. pelliculosa, Phaeodactylum EPV and N. oculata showed less reduction of O₂ evolution and the F(v)/F(m) by TD118. These results imply that the species-specific TD structure relationship may be due to structural and/or physiological differences among microalgal species.

  8. State-of-technology for joining TD-NiCr sheet.

    NASA Technical Reports Server (NTRS)

    Holko, K. H.; Moore, T. J.; Gyorgak, C. A.

    1972-01-01

    At the current state-of-technology there are many joining processes that can be used to make sound welds in TD-NiCr sheet. Some of these that are described in this report are electron beam welding (EBW), gas-tungsten arc welding (GTAW), diffusion welding (DFW), resistance spot welding (RSW), resistance seam welding (RSEW), and brazing. Roll welding (RW) and explosion welding (EXW) have not been developed to the point where they can be used to make sound welds in TD-NiCr. Joining work that has previously been done on TD-NiCr by various organizations, both privately supported and under Air Force and NASA contracts, is described in this summary. Current work is also described that is being done at General Dynamics/Convair (under NASA contract) and at NASA/Lewis to develop and evaluate DFW, RSW, RSEW, and brazing. Preliminary comparisons of joining processes are made for typical applications. A brief description of the manufacture of TD-NiCr sheet by a recently standardized process (under NASA contract) also is given.

  9. Two-phase chromium-niobium alloys exhibiting improved mechanical properties at high temperatures

    DOEpatents

    Liu, C.T.; Takeyama, Masao.

    1994-02-01

    The specification discloses chromium-niobium alloys which exhibit improved mechanical properties at high temperatures in the range of 1250 C and improved room temperature ductility. The alloys contain a Cr[sub 2]Nb-rich intermetallic phase and a Cr-rich phase with an overall niobium concentration in the range of from about 5 to about 18 at. %. The high temperature strength is substantially greater than that of state of the art nickel-based superalloys for enhanced high temperature service. Further improvements in the properties of the compositions are obtained by alloying with rhenium and aluminum; and additional rare-earth and other elements. 14 figures.

  10. The analytical biochemistry of chromium.

    PubMed Central

    Katz, S A

    1991-01-01

    The essentiality and carcinogenicity of chromium depend on its chemical form. Oxidation state and solubility are particularly important in determining the biological effects of chromium compounds. For this reason, total chromium measurements are of little value in assessing its nutritional benefits or its toxicological hazards. Aqueous sodium carbonate-sodium hydroxide solutions have been successfully used for extracting hexavalent chromium from a variety of environmental and biological matrices while preserving its oxidation state. Typical recoveries are 90 to 105% in samples spiked with both trivalent and hexavalent chromium. Determination of hexavalent chromium after extraction with sodium carbonate-sodium hydroxide solution, coupled with the determination of total chromium after nitric acid-hydrogen peroxide digestion, has been applied to the evaluation of chromium speciation in airborne particulates, sludges, and biological tissues. PMID:1935842

  11. 40 CFR 266.100 - Applicability.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... the following requirements, except that an owner or operator of a lead or a nickel-chromium recovery... operator of a lead or nickel-chromium or mercury recovery furnace (except for owners or operators of lead... listed in appendix XII of this part must contain recoverable levels of nickel or chromium, a waste listed...

  12. 40 CFR 266.100 - Applicability.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the following requirements, except that an owner or operator of a lead or a nickel-chromium recovery... operator of a lead or nickel-chromium or mercury recovery furnace (except for owners or operators of lead... listed in appendix XII of this part must contain recoverable levels of nickel or chromium, a waste listed...

  13. Hexavalent Chromium Minimization Strategy

    DTIC Science & Technology

    2011-05-01

    Logistics 4 Initiative - DoD Hexavalent Chromium Minimization Non- Chrome Primer IIEXAVAJ ENT CHRO:M I~UMI CHROMIUM (VII Oil CrfVli.J CANCEfl HAnRD CD...Management Office of the Secretary of Defense Hexavalent Chromium Minimization Strategy Report Documentation Page Form ApprovedOMB No. 0704-0188...00-2011 4. TITLE AND SUBTITLE Hexavalent Chromium Minimization Strategy 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6

  14. The National Shipbuilding Research Program. Impact of Recent and Anticipated Changes in Airborne Emission Exposure Limits on Shipyard Workers

    DTIC Science & Technology

    1996-03-01

    shipyard welders performing GTAW of stainless steels and high chromium nickel alloys are above 0.25 µg/m3 without use of local exhaust ventilation. Local...Manganese, Chromium , and Hexavalent Chromium May Be Encountered...66 5.1 Reduction of Nickel and Hexavalent Chromium Emissions Through

  15. Evaluation of coatings for cobalt- and nickel-base superalloys, volume 2

    NASA Technical Reports Server (NTRS)

    Moore, V. S.; Brentnall, W. D.; Stetson, A. R.

    1970-01-01

    The final results of an oxidation-reduction rig evaluation of aluminide coatings are presented, as applied to 1N-100 and B1900 nickel-base and X-10 and WI-52 cobalt-base alloys. Burner rigs were used which operated on JP-5 fuel and air, producing a gas velocity of 0.85 (2000 to 2500 ft/sec) at the specimen's leading edge. One-hour heating cycles were used with three minutes of air blast cooling. Results of testing at temperatures ranging from T sub max of 1850 to 2050 F indicate that coated B1900 has the longest oxidation life at all temperatures, followed by IN-100X-40WI-52, based on a weight change criterion. Coatings on nickel-base alloys provided more than twice the life of coating on cobalt-base alloys at comparable temperatures. The coatings with higher aluminum content and comparable thickness had longer lives. Silicon appeared to be a beneficial additive in the nickel-base alloy coatings for long term, low temperature life, but not for short term, high temperature performance. Chromium was identified in all coatings. Extrapolating the life results obtained to 1600 F, all the selected coatings on the four alloys would be protective for at least 10,000 hours.

  16. TD-60 links RalA GTPase function to the CPC in mitosis

    PubMed Central

    Papini, Diana; Langemeyer, Lars; Abad, Maria A.; Kerr, Alastair; Samejima, Itaru; Eyers, Patrick A.; Jeyaprakash, A. Arockia; Higgins, Jonathan M. G.; Barr, Francis A.; Earnshaw, William C.

    2015-01-01

    TD-60 (also known as RCC2) is a highly conserved protein that structurally resembles the Ran guanine exchange factor (GEF) RCC1, but has not previously been shown to have GEF activity. TD-60 has a typical chromosomal passenger complex (CPC) distribution in mitotic cells, but associates with integrin complexes and is involved in cell motility during interphase. Here we show that TD-60 exhibits GEF activity, in vitro and in cells, for the small GTPase RalA. TD-60 or RalA depletion causes spindle abnormalities in prometaphase associated with abnormal centromeric accumulation of CPC components. TD-60 and RalA apparently work together to contribute to the regulation of kinetochore–microtubule interactions in early mitosis. Importantly, several mitotic phenotypes caused by TD-60 depletion are reverted by the expression of a GTP-locked mutant, RalA (Q72L). The demonstration that a small GTPase participates in the regulation of the CPC reveals a level of mitotic regulation not suspected in previous studies. PMID:26158537

  17. Investigation of hydrogen evolution activity for the nickel, nickel-molybdenum nickel-graphite composite and nickel-reduced graphene oxide composite coatings

    NASA Astrophysics Data System (ADS)

    Jinlong, Lv; Tongxiang, Liang; Chen, Wang

    2016-03-01

    The nickel, nickel-molybdenum alloy, nickel-graphite and nickel-reduced graphene oxide composite coatings were obtained by the electrodeposition technique from a nickel sulfate bath. Nanocrystalline molybdenum, graphite and reduced graphene oxide in nickel coatings promoted hydrogen evolution reaction in 0.5 M H2SO4 solution at room temperature. However, the nickel-reduced graphene oxide composite coating exhibited the highest electrocatalytic activity for the hydrogen evolution reaction in 0.5 M H2SO4 solution at room temperature. A large number of gaps between 'cauliflower' like grains could decrease effective area for hydrogen evolution reaction in slight amorphous nickel-molybdenum alloy. The synergistic effect between nickel and reduced graphene oxide promoted hydrogen evolution, moreover, refined grain in nickel-reduced graphene oxide composite coating and large specific surface of reduced graphene oxide also facilitated hydrogen evolution reaction.

  18. Mach 1 oxidation of thoriated nickel chromium at 1204 C /2200 F/.

    NASA Technical Reports Server (NTRS)

    Lowell, C. E.; Sanders, W. A.

    1972-01-01

    Electropolished and ground samples of TD-NiCr were exposed to a 1-atm, Mach 1 gas stream at 1204 C for times up to 50 hr. The samples were subjected to both cyclic and isothermal exposure. Weight change, metal loss, X-ray diffraction, metallographic, and electron microprobe analyses were performed. Neither surface preparation nor cyclic-against-isothermal-exposure conditions had a strong effect on the oxidation behavior of the alloy. Initially, a Cr2O3 layer was formed whose volatilization resulted in a very rapid loss of metal - more than 40 microns in the first hour. At about 1 hr, the Cr2O3 layer broke down and NiO began to cover the surface. By 5 hr, the NiO had covered the surface and the rate of loss slowed. The rate-controlling step was diffusion of Cr through NiO.

  19. Carcinogenicity and mutagenicity of chromium.

    PubMed

    Léonard, A; Lauwerys, R R

    1980-11-01

    Occupational exposure represents the main source of human contamination by chromium. For non-occupationally exposed people the major environmental exposure to chromium occurs as a consequence of its presence in food. Chromium must be considered as an essential element. Its deficiency impairs glucose metabolism. Trivalent chromium salts are poorly absorbed through the gastro-intestinal and respiratory tracts because they do not cross membranes easily. Hexavalent chromium can be absorbed by the oral and pulmonary routes and probably also through the skin. After its absorption, hexavalent chromium is rapidly reduced to the trivalent form which is probably the only form to be found in biological material. Epidemiological studies have shown that some chromium salts (mainly the slightly soluble hexavalent salts) are carcinogens. Lung cancers have, indeed, often been reported among workers in chromate-producing industry and, to a lesser extent, in workers from the chrome-pigment industry. The first attempts to produce cancers in experimental animals by inhalation or parenteral introduction gave negative or equivocal results but, from 1960, positive results have been obtained with various chromium compounds. As for the carcinogenic activity, the mutagenicity of chromium has mainly been found with hexavalent salts. In the majority of assay systems used, trivalent chromium appears inactive. It can be considered as evident, however, that the ultimate mutagen which binds to the genetic material is the trivalent form produced intracellularly from hexavalent chromium, the apparent lack of activity of the trivalent form being due to its poor cellular uptake.

  20. Effect of pulp density and particle size on indirect bioleaching of Pomalaa nickel laterite using metabolic citric acid

    NASA Astrophysics Data System (ADS)

    Petrus, H. B. T. M.; Wanta, K. C.; Setiawan, H.; Perdana, I.; Astuti, W.

    2018-01-01

    Nickel laterite ore contains oxide of iron, aluminum or both with nickel, cobalt and chromium which can be leached out using hydrometallurgical process. For the purpose of meeting the world’s increasing demand of nickel, there is a need to invent environmentally friendly process to efficiently leach nickel. This experiment used nickel laterite ore obtained from Pomalaa, South Sulawesi. The leaching agent is metabolic citric acid produced by Aspergillus niger under optimum condition. Leaching process was done in three-necked flask in atmospheric temperature and constant stirring speed of 200 rpm. The variable examined in the experiment was pulp density and particle size of nickel laterite ore. Samples were taken at 3, 7, 10, 14, and 17 minutes and then filtered and diluted to be analyzed using ICP-AES. The result of the experiment showed the maximum recovery of metals increase with the decrease of the pulp density. The maximum recovery for varying pulp density were at 5% solid/liquid ratio and the recovery were Ni at 1.63%, Al at 0.47%, Fe at 0.23% and Mg at 1.09%. The effect of particle size on leaching process showed that the leaching process follows the shrinking core model. The maximum recovery of metals at particle size were at 100-120 mesh with Ni at 1.37%, Fe at 0.10%, Al at 0.72% and Mg at 0.62%.

  1. Citric-acid preacidification enhanced electrokinetic remediation for removal of chromium from chromium-residue-contaminated soil.

    PubMed

    Meng, Fansheng; Xue, Hao; Wang, Yeyao; Zheng, Binghui; Wang, Juling

    2018-02-01

    Electrokinetic experiments were conducted on chromium-residue-contaminated soils collected from a chemical plant in China. Acidification-electrokinetic remediation technology was proposed in order to solve the problem of removing inefficient with ordinary electrokinetic. The results showed that electrokinetic remediation removal efficiency of chromium from chromium-contaminated soil was significantly enhanced with acidizing pretreatment. The total chromium [Cr(T)] and hexavalent chromium [Cr(VI)] removal rate of the group acidized by citric acid (0.9 mol/L) for 5 days was increased from 6.23% and 19.01% in the acid-free experiments to 26.97% and 77.66% in the acidification-treated experiments, respectively. In addition, part of chromium with the state of carbonate-combined will be converted into water-soluble state through acidification to improve the removal efficiency. Within the appropriate concentration range, the higher concentration of acid was, the more chromium was released. So the removal efficiency of chromium depended on the acid concentration. The citric acid is also a kind of complexing agent, which produced complexation with Cr that was released by the electrokinetic treatment and then enhanced the removal efficiency. The major speciation of chromium that was removed from soils by acidification-electrokinetics remediation was acid-soluble speciation, revivification speciation and oxidation speciation, which reduced biological availability of chromium.

  2. Chromium carcinogenicity: California strategies.

    PubMed

    Alexeeff, G V; Satin, K; Painter, P; Zeise, L; Popejoy, C; Murchison, G

    1989-10-01

    Hexavalent chromium was identified by California as a toxic air contaminant (TAC) in January 1986. The California Department of Health Services (CDHS) concurred with the findings of the International Agency for Research on Cancer that there is sufficient evidence to demonstrate the carcinogenicity of chromium in both animals and humans. CDHS did not find any compelling evidence demonstrating the existence of a threshold with respect to chromium carcinogenesis. Experimental data was judged inadequate to assess potential human reproductive risks from ambient exposures. Other health effects were not expected to occur at ambient levels. The theoretically increased lifetime carcinogenic risk from a continuous lifetime exposure to hexavalent chromium fell within the range 12-146 cancer cases per nanogram hexavalent chromium per cubic meter of air per million people exposed, depending on the potency estimate used. The primary sources found to contribute significantly to the risk of exposure were chrome platers, chromic acid anodizing facilities and cooling towers utilizing hexavalent chromium as a corrosion inhibitor. Evaluation of genotoxicity data, animal studies and epidemiological studies indicates that further consideration should be given to the potential carcinogenicity of hexavalent chromium via the oral route.

  3. Fume generation and content of total chromium and hexavalent chromium in flux-cored arc welding.

    PubMed

    Yoon, Chung Sik; Paik, Nam Won; Kim, Jeong Han

    2003-11-01

    This study was performed to investigate the fume generation rates (FGRs) and the concentrations of total chromium and hexavalent chromium when stainless steel was welded using flux-cored arc welding (FCAW) with CO2 gas. FGRs and concentrations of total chromium and hexavalent chromium were quantified using a method recommended by the American Welding Society, inductively coupled plasma-atomic emission spectroscopy (NIOSH Method 7300) and ion chromatography (modified NIOSH Method 7604), respectively. The amount of total fume generated was significantly related to the level of input power. The ranges of FGR were 189-344, 389-698 and 682-1157 mg/min at low, optimal and high input power, respectively. It was found that the FGRs increased with input power by an exponent of 1.19, and increased with current by an exponent of 1.75. The ranges of total chromium fume generation rate (FGRCr) were 3.83-8.27, 12.75-37.25 and 38.79-76.46 mg/min at low, optimal and high input power, respectively. The ranges of hexavalent chromium fume generation rate (FGRCr6+) were 0.46-2.89, 0.76-6.28 and 1.70-11.21 mg/min at low, optimal and high input power, respectively. Thus, hexavalent chromium, which is known to be a carcinogen, generated 1.9 (1.0-2.7) times and 3.7 (2.4-5.0) times as the input power increased from low to optimal and low to high, respectively. As a function of input power, the concentration of total chromium in the fume increased from 1.57-2.65 to 5.45-8.13% while the concentration of hexavalent chromium ranged from 0.15 to 1.08%. The soluble fraction of hexavalent chromium produced by FCAW was approximately 80-90% of total hexavalent chromium. The concentration of total chromium and the solubility of hexavalent chromium were similar to those reported from other studies of shielded metal arc welding fumes, and the concentration of hexavalent chromium was similar to that obtained for metal inert gas-welding fumes.

  4. A Hard X-ray Study of a Manganese-Terpyridine Dimer Catalyst in a Chromium-based Metal Organic Framework - Oral Presentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ramsey, Alexandra

    2015-08-25

    Cleaner forms of energy are needed, and H 2 produced from water spliFng is a possible source. However, a robust catalyst is necessary to carry out the water oxidaKon reacKon. Plants uKlize Photosystem II to catalyze water oxidaKon as a part of photosynthesis, and many syntheKc water oxidaKon catalysts use Photosystem II as a model. In this study, the catalyst of interest was [(terpy)Mn(μ-O)2Mn(terpy)]3+ (MnTD), which was synthesized in a chromium-based Metal Organic Framework (MOF) to avoid degradaKon of MnTD molecules. Hard X-ray powder diffracKon was the primary method of analysis. The diffracKon data was used to detect the presencemore » of MOF in samples at different catalyKc stages, and laFce parameters were assigned to the samples containing MOF. Fourier maps were constructed to determine the contents of the MOF as preliminary studies suggested that MnTD may not be present. Results showed that MOF is present before catalysis occurs, but disappears in the iniKal stages of catalysis. Changes in the MOF’s laFce parameters suggest aWracKve interacKons between the MOF and catalyst; these interacKons may lead to the observed MOF degradaKon. Fourier maps also reveal limited, if any, amounts of MnTD in the system. Molecular manganese oxide may be the source of the high rate of water oxidaKon catalysis in the studied system.« less

  5. Efficacy of dietary chromium (III) supplementation on tissue chromium deposition in finishing pigs.

    PubMed

    Wang, Min-Qi; Li, Hui; He, Yu-Dan; Wang, Chao; Tao, Wen-Jing; Du, Yong-Jie

    2012-09-01

    The study was conducted to evaluate the efficacy of different forms of trivalent chromium (Cr) supplementation on tissue chromium deposition in finishing pigs. A total of 96 pigs with an initial average body mass 65.57±1.05 kg were blocked by body mass and randomly assigned to four treatments with three replicates. Pigs were offered one of four diets including a control diet or the control diet supplemented with 200 μg/kg chromium from either chromium chloride (CrCl(3)), chromium picolinate (CrPic) or chromium nanocomposite (CrNano) for 40 days. During the trial, all pigs were given free access to feed and water. After feeding trial, eight pigs from each treatment were slaughtered for samples collection. The results showed that supplemental CrNano increased Cr content in blood, longissimus muscle, heart, liver, kidney, jejunum, and ileum (P<0.05). Supplemental Cr from three sources increased Cr excretion from all feces (P<0.05). Urinary Cr excretion was increased by CrNano or CrPic supplementation significantly. These results suggested that chromium nanocomposite exhibited more effective on tissue Cr deposition in pigs, which indicated higher absorption compared with CrCl(3) and CrPic.

  6. The carcinogenicity of chromium

    PubMed Central

    Norseth, Tor

    1981-01-01

    The carcinogenicity of chromium compounds is reviewed with specific attention to the gaps in knowledge for risk estimation and research needs. The most important problems at present are whether trivalent chromium compounds cause cancer, and whether there is a difference in cancer causing effects between the soluble and the slightly soluble hexavalent compounds in the practical exposure situation. Dose estimates for risk estimation based on epidemiological investigations are also lacking. Present evidence indicates that the trivalent chromium compounds do not cause cancer although high concentrations in some in vitro systems have shown genetic toxicity. Hexavalent chromium compounds cause cancer in humans, in experimental animals and exert genetic toxicity in bacteria and in mammalian cells in vitro. Epidemiological evidence and animal experiments indicate that the slightly soluble hexavalent salts are the most potent carcinogens, but proper identification and characterization of exposure patterns in epidemiological work are lacking. Workers also tend to have mixed exposures. Soluble and slightly soluble salts are equally potent genotoxic agents in vitro. Further work for establishing dose estimates for risk evaluation in epidemiological work is important. In vitro systems should be applied for further identification of the mechanism of the carcinogenic effects, and animal experiments are urgent for comparison of the carcinogenic potency of the different hexavalent salts. Hexavalent chromium salts must be regarded as established carcinogens, and proper action should be taken in all industries with regard to such exposure. At present the carcinogenic risk to the general population caused by chromium compounds seems to be negligible, chromium in cigarettes, however, is an uncertainty in this respect. The amount of chromium and the type of chromium compounds inhaled from cigarettes is not known. PMID:7023928

  7. 40 CFR 471.91 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... million off-pounds) of zirconium-hafnium extruded Chromium 0.104 0.043 Cyanide 0.069 0.029 Nickel 0.455 0... million off-pounds) of zirconium-hafnium heat treated Chromium 0.151 0.062 Cyanide 0.100 0.041 Nickel 0...-hafnium surface treated Chromium 0.150 0.61 Cyanide 0.099 0.041 Nickel 0.653 0.432 Ammonia 45.3 20...

  8. 40 CFR 471.91 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... million off-pounds) of zirconium-hafnium extruded Chromium 0.104 0.043 Cyanide 0.069 0.029 Nickel 0.455 0... million off-pounds) of zirconium-hafnium heat treated Chromium 0.151 0.062 Cyanide 0.100 0.041 Nickel 0...-hafnium surface treated Chromium 0.150 0.61 Cyanide 0.099 0.041 Nickel 0.653 0.432 Ammonia 45.3 20...

  9. 40 CFR 420.106 - Pretreatment standards for new sources (PSNS).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (pounds per 1,000 lb) of product Chromium 1 0.0000209 0.0000084 Lead 0.0000094 0.0000031 Nickel 1 0... limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling... Chromium 1 0.0000418 0.0000167 Lead 0.0000188 0.0000063 Nickel 1 0.0000376 0.0000125 Zinc 0.0000125 0...

  10. 40 CFR 420.106 - Pretreatment standards for new sources (PSNS).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (pounds per 1,000 lb) of product Chromium 1 0.0000209 0.0000084 Lead 0.0000094 0.0000031 Nickel 1 0... limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling... Chromium 1 0.0000418 0.0000167 Lead 0.0000188 0.0000063 Nickel 1 0.0000376 0.0000125 Zinc 0.0000125 0...

  11. 40 CFR 420.106 - Pretreatment standards for new sources (PSNS).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (pounds per 1,000 lb) of product Chromium 1 0.0000209 0.0000084 Lead 0.0000094 0.0000031 Nickel 1 0... limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling... Chromium 1 0.0000418 0.0000167 Lead 0.0000188 0.0000063 Nickel 1 0.0000376 0.0000125 Zinc 0.0000125 0...

  12. 40 CFR 420.86 - Pretreatment standards for new sources (PSNS).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .../kkg (pounds per 1,000 lb) of product Chromium 0.00292 0.00117 Nickel 0.00263 0.000876 (2) Batch, rod... Chromium 0.00175 0.000701 Nickel 0.00158 0.000526 (3) Batch, pipe and tube. Subpart H Pollutant or... 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product Chromium 0.00709 0.00284 Nickel 0.00638 0...

  13. 40 CFR 420.86 - Pretreatment standards for new sources (PSNS).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .../kkg (pounds per 1,000 lb) of product Chromium 0.00292 0.00117 Nickel 0.00263 0.000876 (2) Batch, rod... Chromium 0.00175 0.000701 Nickel 0.00158 0.000526 (3) Batch, pipe and tube. Subpart H Pollutant or... 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product Chromium 0.00709 0.00284 Nickel 0.00638 0...

  14. 40 CFR 420.86 - Pretreatment standards for new sources (PSNS).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .../kkg (pounds per 1,000 lb) of product Chromium 0.00292 0.00117 Nickel 0.00263 0.000876 (2) Batch, rod... Chromium 0.00175 0.000701 Nickel 0.00158 0.000526 (3) Batch, pipe and tube. Subpart H Pollutant or... 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product Chromium 0.00709 0.00284 Nickel 0.00638 0...

  15. 40 CFR 420.106 - Pretreatment standards for new sources (PSNS).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (pounds per 1,000 lb) of product Chromium 1 0.0000209 0.0000084 Lead 0.0000094 0.0000031 Nickel 1 0... limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling... Chromium 1 0.0000418 0.0000167 Lead 0.0000188 0.0000063 Nickel 1 0.0000376 0.0000125 Zinc 0.0000125 0...

  16. 40 CFR 420.106 - Pretreatment standards for new sources (PSNS).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (pounds per 1,000 lb) of product Chromium 1 0.0000209 0.0000084 Lead 0.0000094 0.0000031 Nickel 1 0... limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling... Chromium 1 0.0000418 0.0000167 Lead 0.0000188 0.0000063 Nickel 1 0.0000376 0.0000125 Zinc 0.0000125 0...

  17. 29 CFR 1926.1126 - Chromium (VI).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... activity involving chromium cannot release dusts, fumes, or mists of chromium (VI) in concentrations at or... 29 Labor 8 2014-07-01 2014-07-01 false Chromium (VI). 1926.1126 Section 1926.1126 Labor... Chromium (VI). (a) Scope. (1) This standard applies to occupational exposures to chromium (VI) in all forms...

  18. 29 CFR 1926.1126 - Chromium (VI).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... activity involving chromium cannot release dusts, fumes, or mists of chromium (VI) in concentrations at or... 29 Labor 8 2012-07-01 2012-07-01 false Chromium (VI). 1926.1126 Section 1926.1126 Labor... Chromium (VI). (a) Scope. (1) This standard applies to occupational exposures to chromium (VI) in all forms...

  19. 29 CFR 1926.1126 - Chromium (VI).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... activity involving chromium cannot release dusts, fumes, or mists of chromium (VI) in concentrations at or... 29 Labor 8 2011-07-01 2011-07-01 false Chromium (VI). 1926.1126 Section 1926.1126 Labor... Chromium (VI). (a) Scope. (1) This standard applies to occupational exposures to chromium (VI) in all forms...

  20. 29 CFR 1926.1126 - Chromium (VI).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... activity involving chromium cannot release dusts, fumes, or mists of chromium (VI) in concentrations at or... 29 Labor 8 2013-07-01 2013-07-01 false Chromium (VI). 1926.1126 Section 1926.1126 Labor... Chromium (VI). (a) Scope. (1) This standard applies to occupational exposures to chromium (VI) in all forms...

  1. Biological groundwater treatment for chromium removal at low hexavalent chromium concentrations.

    PubMed

    Mamais, Daniel; Noutsopoulos, Constantinos; Kavallari, Ioanna; Nyktari, Eleni; Kaldis, Apostolos; Panousi, Eleni; Nikitopoulos, George; Antoniou, Kornilia; Nasioka, Maria

    2016-06-01

    The objective of this work is to develop and evaluate biological groundwater treatment systems that will achieve hexavalent chromium reduction and total chromium removal from groundwater at hexavalent chromium (Cr(VI)) groundwater concentrations in the 0-200 μg/L range. Three lab-scale units operated, as sequencing batch reactors (SBR) under aerobic, anaerobic and anaerobic-aerobic conditions. All systems received groundwater with a Cr(VI) content of 200 μg/L. In order to support biological growth, groundwater was supplemented with milk, liquid cheese whey or a mixture of sugar and milk to achieve a COD concentration of 200 mg/L. The results demonstrate that a fully anaerobic system or an anaerobic-aerobic system dosed with simple or complex external organic carbon sources can lead to practically complete Cr(VI) reduction to Cr(III). The temperature dependency of maximum Cr(VI) removal rates can be described by the Arrhenius relationship. Total chromium removal in the biological treatment systems was not complete because a significant portion of Cr(III) remained in solution. An integrated system comprising of an anaerobic SBR followed by a sand filter achieved more than 95% total chromium removal thus resulting in average effluent total and dissolved chromium concentrations of 7 μg/L and 3 μg/L, respectively. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. The hazardous hexavalent chromium formed on trivalent chromium conversion coating: The origin, influence factors and control measures.

    PubMed

    Li, Jinhua; Yao, Chenlan; Liu, Yanbiao; Li, Di; Zhou, Baoxue; Cai, Weimin

    2012-06-30

    In this paper, the effects of processing parameters and constituents of treating-agent on the presence of hazardous hexavalent chromium on trivalent chromium conversion coating were studied. Results showed that shorter immersion time, lower bath pH value as well as lower working and baking temperatures retarded the presence of hexavalent chromium. In addition, the concentration of hexavalent chromium on conversion coatings prepared by the oxalic acid treating-agent was far greater than those on conversion coatings prepared by formic acid and acetic acid treating-agents. Results also indicated that the concentration of hexavalent chromium on conversion coatings was enhanced due to the addition of bivalent cobalt and nitrate anion in treating-agent, especially for oxalic acid conversion coating. However, the addition of hydroxyl compound d-gluconic acid in treating-agent could reduce the concentration of hexavalent chromium effectively. Moreover, a possible formation mechanism of hexavalent chromium on trivalent conversion coating was proposed. Findings of this study provide a better understanding of the formation of hexavalent chromium on trivalent chromium conversion coating and can facilitate the management of trivalent chromium treating-agents and trivalent chromium fasteners. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Exploratory Investigation of Advanced-Temperature Nickel-Base Alloys

    NASA Technical Reports Server (NTRS)

    Freche, John C.; Waters, William J.

    1959-01-01

    An investigation was conducted to provide an advanced-temperature nickel-base alloy with properties suitable for aircraft turbine blades as well as for possible space vehicle applications. An entire series of alloys that do not require vacuum melting techniques and that generally provide good stress-rupture and impact properties was evolved. The basic-alloy composition of 79 percent nickel, 8 percent molybdenum, 6 percent chromium, 6 percent aluminum, and 1 percent zirconium was modified by a series of element additions such as carbon, titanium, and boron, with the nickel content adjusted to account for the additives. Stress-rupture, impact, and swage tests were made with all the alloys. The strongest composition (basic alloy plus 1.5 percent titanium plus 0.125 percent carbon) displayed 384- and 574-hour stress-rupture lives at 1800 F and 15,000 psi in the as-cast and homogenized conditions, respectively. All the alloys investigated demonstrated good impact resistance. Several could not be broken in a low-capacity Izod impact tester and, on this basis, all compared favorably with several high-strength high-temperature alloys. Swaging cracks were encountered with all the alloys. In several cases, however, these cracks were slight and could be detected only by zyglo examination. Some of these compositions may become amenable to hot working on further development. On the basis of the properties indicated, it appears that several of the alloys evolved, particularly the 1.5 percent titanium plus 0.125 percent carbon basic-alloy modification, could be used for advanced- temperature turbine blades, as well as for possible space vehicle applications.

  4. Adverse health effects of child labor: high exposure to chromium and oxidative DNA damage in children manufacturing surgical instruments.

    PubMed

    Sughis, Muhammad; Nawrot, Tim S; Haufroid, Vincent; Nemery, Benoit

    2012-10-01

    A considerable part of the worldwide production of surgical instruments takes place in Sialkot, Pakistan. Many children work in hazardous conditions in this industry. We investigated exposure to metals and possible health effects among children working in surgical instruments manufacturing units compared with schoolchildren from the same city. In a cross-sectional study we studied a convenience sample of 104 male children (10-14 years of age) working in surgical instruments manufacturing units and 75 male children of similar age from a school in Sialkot, Pakistan. A respiratory questionnaire was administered, spirometry was performed, and blood pressure was measured. In a spot urine sample, concentrations of metals were measured by inductively coupled plasma mass spectrometry and 8-hydroxydeoxyguanosine (8OHdG, reflecting oxidative DNA damage) by ELISA. The working children reported more asthma (10% vs. 0%; p = 0.005) and dry cough at night (36% vs. 20%; p = 0.02) than did the schoolchildren, but there were no significant differences in pulmonary function or blood pressure. The urinary concentration of chromium was 35 times higher in working children [geometric mean, 23.0 µg/L; 25th-75th percentile, 8.38-58.6] than in schoolchildren [0.66 µg/L; 0.38-1.09)], and largely in excess of the occupational Biological Exposure Index for adult workers (25 µg/L). Urinary 8-OHdG concentrations were not significantly higher in working children than in schoolchildren (19.3 vs. 17.6 µg/g creatinine, p = 0.4), but were significantly correlated with urinary nickel (r = 0.41; p < 0.0001) and with a composite index of metal exposure (r = 0.46; p < 0.0001). Children working in the surgical instruments manufacturing industry had substantial exposure to several metals, especially chromium and nickel, which are established carcinogens. Exposure to nickel was associated with evidence of increased oxidative DNA damage.

  5. Chromium and Genomic Stability

    PubMed Central

    Wise, Sandra S.; Wise, John Pierce

    2014-01-01

    Many metals serve as micronutrients which protect against genomic instability. Chromium is most abundant in its trivalent and hexavalent forms. Trivalent chromium has historically been considered an essential element, though recent data indicate that while it can have pharmacological effects and value, it is not essential. There are no data indicating that trivalent chromium promotes genomic stability and, instead may promote genomic instability. Hexavalent chromium is widely accepted as highly toxic and carcinogenic with no nutritional value. Recent data indicate that it causes genomic instability and also has no role in promoting genomic stability. PMID:22192535

  6. 40 CFR 421.322 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... refinery Chromium 32.270 13.200 Copper 139.300 73.340 Nickel 140.800 93.140 Fluoride 2,567.000 1,459.000... processed in the refinery Chromium (total) 2.009 0.822 Copper 8.675 4.566 Nickel 8.767 5.799 Fluoride 159... pounds) of uranium processed in the refinery Chromium (total) 2.802 1.146 Copper 12.100 6.369 Nickel 12...

  7. 40 CFR 421.322 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... refinery Chromium 32.270 13.200 Copper 139.300 73.340 Nickel 140.800 93.140 Fluoride 2,567.000 1,459.000... processed in the refinery Chromium (total) 2.009 0.822 Copper 8.675 4.566 Nickel 8.767 5.799 Fluoride 159... pounds) of uranium processed in the refinery Chromium (total) 2.802 1.146 Copper 12.100 6.369 Nickel 12...

  8. Transceiver Multiplexers TD-1288( )/GRC and TD-1289( )(V)/GRC.

    DTIC Science & Technology

    1982-02-01

    TRASITCAS TD-1289( )iV)1/GRC C.76 IR BANPAS FLER TERMINATION UNIT CU26()/GRC] G -42 RC MX-10080t )/GRC F’igure l-l. X1liF’ MultipleXer amily Tree. F1- CU-2266...the equations become: Y G o t Q 1Q+/Qu C o s 0 = j2 + Q QU L° l~ Qu I+j L=010 log 4 + j 2 Qt The passband loss expression may be simplified to read: 4...a character istic impedance of 50 oims. The linle len,_tli was 16i.5 inches and was tet oiinated inl a -ohio If load. The tap pointt was nojusted to g

  9. Evaluation of effect of galvanic corrosion between nickel-chromium metal and titanium on ion release and cell toxicity

    PubMed Central

    Choi, Jung-Yun

    2015-01-01

    PURPOSE The purpose of this study was to evaluate cell toxicity due to ion release caused by galvanic corrosion as a result of contact between base metal and titanium. MATERIALS AND METHODS It was hypothesized that Nickel (Ni)-Chromium (Cr) alloys with different compositions possess different corrosion resistances when contacted with titanium abutment, and therefore in this study, specimens (10×10×1.5 mm) were fabricated using commercial pure titanium and 3 different types of Ni-Cr alloys (T3, Tilite, Bella bond plus) commonly used for metal ceramic restorations. The specimens were divided into 6 groups according to the composition of Ni-Cr alloy and contact with titanium. The experimental groups were in direct contact with titanium and the control groups were not. After the samples were immersed in the culture medium - Dulbecco's modified Eagle's medium[DMEM] for 48 hours, the released metal ions were detected using inductively coupled plasma mass spectrometer (ICP-MS) and analyzed by the Kruskal-Wallis and Mann-Whitney test (P<.05). Mouse L-929 fibroblast cells were used for cell toxicity evaluation. The cell toxicity of specimens was measured by the 3-{4,5-dimethylthiazol-2yl}-2,5-diphenyltetrazolium bromide (MTT) test. Results of MTT assay were statistically analyzed by the two-way ANOVA test (P<.05). Post-hoc multiple comparisons were conducted using Tukey's tests. RESULTS The amount of metal ions released by galvanic corrosion due to contact between the base metal alloy and titanium was increased in all of the specimens. In the cytotoxicity test, the two-way ANOVA showed a significant effect of the alloy type and galvanic corrosion for cytotoxicity (P<.001). The relative cell growth rate (RGR) was decreased further on the groups in contact with titanium (P<.05). CONCLUSION The release of metal ions was increased by galvanic corrosion due to contact between base metal and titanium, and it can cause adverse effects on the tissue around the implant by inducing

  10. Hexavalent Chromium Compounds

    Cancer.gov

    Learn about chromium, exposure to which can increase your risk of lung cancer and cancer of the paranasal sinuses and nasal cavity. Hexavalent chromium compounds have been used as corrosion inhibitors in a wide variety of products and processes.

  11. Characterization and cytotoxicity of ions released from stainless steel and nickel-titanium orthodontic alloys.

    PubMed

    Eliades, Theodore; Pratsinis, Harris; Kletsas, Dimitris; Eliades, George; Makou, Margarita

    2004-01-01

    The purpose of this study was to qualitatively and quantitatively characterize the substances released from orthodontic brackets and nickel-titanium wires and to comparatively assess the cytotoxicity of the ions released from these orthodontic alloys. Two full sets of stainless steel brackets of 20 brackets each (weight 2.1 g) and 2 groups of 0.018 x 0.025 Ni-Ti archwires of 10 wires each (weight 2.0 g) were immersed in 0.9% saline solution for a month. The immersion media were analyzed with inductively coupled plasma-atomic emission spectroscopy (ICP-AES), and the ionic content was statistically analyzed with 1-way analysis of variance (ANOVA). Human periodontal ligament fibroblasts and gingival fibroblasts were exposed to various concentrations of the 2 immersion media; nickel chloride was used as a positive control for comparison purposes. The cytotoxic or cytostatic activity of the media was investigated with the MTT and the DNA synthesis assays. The results of the cytotoxicity assay were analyzed with 2-way ANOVA and the Tukey test with solution and concentration variants as discriminating variables (alpha=0.05). The results indicated no ionic release for the nickel-titanium alloy aging solution, whereas measurable nickel and traces of chromium were found in the stainless steel bracket-aging medium. Concentrations of the nickel chloride solution greater then 2 mM were found to reduce by more than 50% the viability and DNA synthesis of fibroblasts; however, neither orthodontic materials-derived media had any effect on the survival and DNA synthesis of either cells.

  12. Effects of silver and group II fluoride solid lubricant additions to plasma-sprayed chromium carbide coatings for foil gas bearings to 650 C

    NASA Technical Reports Server (NTRS)

    Wagner, R. C.; Sliney, Harold E.

    1986-01-01

    A new self-lubricating coating composition of nickel aluminide-bonded chromium carbide formulated with silver and Group II fluorides was developed in a research program on high temperature solid lubricants. One of the proposed applications for this new coating composition is as a wide temperature spectrum solid lubricant for complaint foil gas bearings. Friction and wear properties were obtained using a foil gas bearing start-stop apparatus at temperatures from 25 to 650 C. The journals were Inconel 748. Some were coated with the plasma sprayed experimental coating, others with unmodified nickel aluminide/chromium carbide as a baseline for comparison. The additional components were provided to assist in achieving low friction over the temperature range of interest. Uncoated, preoxidized Inconel X-750 foil bearings were operated against these surfaces. The foils were subjected to repeated start/stop cycles under a 14-kPa (2-Psi) bearing unit loading. Sliding contact occurred during lift-off and coastdown at surface velocities less than 6 m/s (3000 rPm). Testing continued until 9000 start/stop cycles were accumulated or until a rise in starting torque indicated the journal/bearing had failed. Comparison in coating performance as well as discussions of their properties and methods of application are given.

  13. Evaluation of scalp hair nickel and chromium level changes in patients with fixed orthodontic appliance: a one-year follow-up study.

    PubMed

    Jamshidi, Saman; Rahmati Kamel, Manouchehr; Mirzaie, Maysam; Sarrafan, Ahmadreza; Khafri, Soraya; Parsian, Hadi

    2018-01-01

    The release of metal ions from orthodontic appliances is part of the dissolution and biomechanical processes of alloys. Nickel (Ni) and chromium (Cr) are the elements commonly used in the manufacture of various components of fixed orthodontic appliances, including bands, brackets and wires. This study was aimed to measure the Ni and Cr ions levels in the scalp hair of patients treated with fixed orthodontic appliances in comparison of the control group. The patient group consisted of 24 patients treated with fixed orthodontic appliances for one year, while the control group included 28 healthy individuals without orthodontic appliances. Analysis of the Cr and Ni was performed using atomic absorption spectrophotometer by graphite furnace method. The data were analyzed via student and paired samples t-test and ANOVA repeated measurement test. After one year, the levels of Ni and Cr in two groups showed significant differences (0.086 ± 0.007 and 0.258 ± 0.009 µg/g for control group and 0.149 ± 0.010 and 0.339 ± 0.013 µg/g for patient group, respectively for Ni and Cr, p < .001). ANCOVA test by removing the effects of age, gender and the baseline levels of Ni and Cr showed that changes in these ions in the scalp hair of both groups after one year were statistically significant. Due to the slightly elevated levels of Ni and Cr ions in the scalp hair of patients treated with fixed orthodontic appliances and considering the cytotoxic and allergic effects of these ions, changing the ingredients in fixed orthodontic appliances is suggested for the future.

  14. Hollow tin/chromium whiskers

    NASA Astrophysics Data System (ADS)

    Cheng, Jing; Vianco, Paul T.; Li, James C. M.

    2010-05-01

    Tin whiskers have been an engineering challenge for over five decades. The mechanism has not been agreed upon thus far. This experiment aimed to identify a mechanism by applying compressive stresses to a tin film evaporated on silicon substrate with an adhesion layer of chromium in between. A phenomenon was observed in which hollow whiskers grew inside depleted areas. Using focused ion beam, the hollow whiskers were found to contain both tin and chromium. At the bottom of the depleted areas, thin tin/tin oxide film remained over the chromium layer. It indicates that tin transport occurred along the interface between tin and chromium layers.

  15. Characterization of Thermophilic Halotolerant Aeribacillus pallidus TD1 from Tao Dam Hot Spring, Thailand

    PubMed Central

    Yasawong, Montri; Areekit, Supatra; Pakpitchareon, Arda; Santiwatanakul, Somchai; Chansiri, Kosum

    2011-01-01

    The bacterial strain TD1 was isolated from Tao Dam hot spring in Thailand. Strain TD1 was Gram positive, rod-shaped, aerobic, motile, and endospore forming. The cell was 2.0–40 μm in length and about 0.4 μm in diameter. The optimum growth occurred at 55–60 °C and at pH 7–8. Strain TD1 was able to grow on medium containing up to 10% NaCl. The DNA G+C content was 38.9 mol%. The cellular fatty acid content was mainly C16:0, which comprised 25.04% of the total amount of cellular fatty acid. 16S rDNA showed 99% identity to Aeribacillus pallidus DSM 3670T. Bayesian tree analysis strongly supported the idea that strain TD1 is affiliated with genus Aeribacillus, as Aeribacillus pallidus strain TD1. Although the 16S rDNA of A. pallidus strain TD1 is similar to that of A. pallidus DSM 3670T, some physiological properties and the cellular fatty acid profiles differ significantly. A. pallidus strain TD1 can produce extracellular pectate lyase, which has not been reported elsewhere for other bacterial strains in the genus Aeribacillus. A. pallidus strain TD1 may be a good candidate as a pectate lyase producer, which may have useful industrial applications. PMID:21954359

  16. 40 CFR 471.94 - Pretreatment standards for existing sources (PSES).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...-hafnium extruded Chromium 0.104 0.043 Cyanide 0.069 0.029 Nickel 0.455 0.301 Ammonia 31.6 13.9 Fluoride 14...-hafnium heat treated Chromium 0.015 0.006 Cyanide 0.010 0.004 Nickel 0.066 0.044 Ammonia 4.57 2.01...-hafnium surface treated Chromium 0.150 0.061 Cyanide 0.099 0.041 Nickel 0.653 0.432 Ammonia 45.3 20.0...

  17. 40 CFR 471.95 - Pretreatment standards for new sources (PSNS).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... extruded Chromium 0.104 0.043 Cyanide 0.069 0.029 Nickel 0.455 0.301 Ammonia 31.6 13.9 Fluoride 14.1 6.26...-hafnium heat treated Chromium 0.015 0.006 Cyanide 0.010 0.004 Nickel 0.066 0.044 Ammonia 4.57 2.01...-hafnium surface treated Chromium 0.150 0.061 Cyanide 0.099 0.041 Nickel 0.653 0.432 Ammonia 45.3 20...

  18. 40 CFR 471.95 - Pretreatment standards for new sources (PSNS).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... extruded Chromium 0.104 0.043 Cyanide 0.069 0.029 Nickel 0.455 0.301 Ammonia 31.6 13.9 Fluoride 14.1 6.26...-hafnium heat treated Chromium 0.015 0.006 Cyanide 0.010 0.004 Nickel 0.066 0.044 Ammonia 4.57 2.01...-hafnium surface treated Chromium 0.150 0.061 Cyanide 0.099 0.041 Nickel 0.653 0.432 Ammonia 45.3 20...

  19. 40 CFR 471.94 - Pretreatment standards for existing sources (PSES).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-hafnium extruded Chromium 0.104 0.043 Cyanide 0.069 0.029 Nickel 0.455 0.301 Ammonia 31.6 13.9 Fluoride 14...-hafnium heat treated Chromium 0.015 0.006 Cyanide 0.010 0.004 Nickel 0.066 0.044 Ammonia 4.57 2.01...-hafnium surface treated Chromium 0.150 0.061 Cyanide 0.099 0.041 Nickel 0.653 0.432 Ammonia 45.3 20.0...

  20. A 1/10 Scale Pilot Plant for the Ecological Demilitarization of Mk 25 Marine Location Markers/Red Phosphorus Composition

    DTIC Science & Technology

    1977-11-11

    zinc, chromium and nickel) in the phosphoric acid, there is no published specification on the maximum allowable concentrations of these metals for...became dark green after burning two batches of the composition. Extraction of chromium and nickel from the scrubber construction material (stainless...steel 316) by the acid at high temperatures (usually greater than 800°F at the inlet of the scrubber) was suspected. The chromium and nickel

  1. Preliminary Material Properties Handbook. Volume 2: SI Units

    DTIC Science & Technology

    2000-07-01

    6-1 6.2 Iron- Chromium -Nickel-Base Alloys...iron, or chromium . In addition to strengthening of titanium by the alloying additions, alpha-beta alloys may be further strengthened by heat...6.3.3 6.3.4 6.3.5 6.4 6.5 6.5.1 Iron- Chromium -Nickel-Base Alloys Nickel-Base Alloys AEREX® 350 alloy HAYNES® 230® alloy HAYNES® HR-120® alloy Inconel

  2. Potential of Live Spirulina platensis on Biosorption of Hexavalent Chromium and Its Conversion to Trivalent Chromium.

    PubMed

    Colla, Luciane Maria; Dal'Magro, Clinei; De Rossi, Andreia; Thomé, Antônio; Reinehr, Christian Oliveira; Bertolin, Telma Elita; Costa, Jorge Alberto Vieira

    2015-01-01

    Microalga biomass has been described worldwide according their capacity to realize biosorption of toxic metals. Chromium is one of the most toxic metals that could contaminate superficial and underground water. Considering the importance of Spirulina biomass in production of supplements for humans and for animal feed we assessed the biosorption of hexavalent chromium by living Spirulina platensis and its capacity to convert hexavalent chromium to trivalent chromium, less toxic, through its metabolism during growth. The active biomass was grown in Zarrouk medium diluted to 50% with distilled water, keeping the experiments under controlled conditions of aeration, temperature of 30°C and lighting of 1,800 lux. Hexavalent chromium was added using a potassium dichromate solution in fed-batch mode with the aim of evaluate the effect of several additions contaminant in the kinetic parameters of the culture. Cell growth was affected by the presence of chromium added at the beginning of cultures, and the best growth rates were obtained at lower metal concentrations in the medium. The biomass removed until 65.2% of hexavalent chromium added to the media, being 90.4% converted into trivalent chromium in the media and 9.6% retained in the biomass as trivalent chromium (0.931 mg.g(-1)).

  3. Electrochemical Removal of Chromium from Wastewater

    DTIC Science & Technology

    1992-07-15

    chromium removal from a wastewater stream. In one process, electrodeposition of chromium on a reticulated vitreous carbon cathode was proposed [5]. On a...reduction to metallic chromium more difficult [31. Removal of hexavalent chromium by adsorption on activated carbon is not suf- ficiently effective to be

  4. 29 CFR 1915.1026 - Chromium (VI).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... a specific process, operation, or activity involving chromium cannot release dusts, fumes, or mists... 29 Labor 7 2012-07-01 2012-07-01 false Chromium (VI). 1915.1026 Section 1915.1026 Labor... § 1915.1026 Chromium (VI). (a) Scope. (1) This standard applies to occupational exposures to chromium (VI...

  5. 29 CFR 1915.1026 - Chromium (VI).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... a specific process, operation, or activity involving chromium cannot release dusts, fumes, or mists... 29 Labor 7 2011-07-01 2011-07-01 false Chromium (VI). 1915.1026 Section 1915.1026 Labor... § 1915.1026 Chromium (VI). (a) Scope. (1) This standard applies to occupational exposures to chromium (VI...

  6. 29 CFR 1915.1026 - Chromium (VI).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... a specific process, operation, or activity involving chromium cannot release dusts, fumes, or mists... 29 Labor 7 2013-07-01 2013-07-01 false Chromium (VI). 1915.1026 Section 1915.1026 Labor... § 1915.1026 Chromium (VI). (a) Scope. (1) This standard applies to occupational exposures to chromium (VI...

  7. 29 CFR 1915.1026 - Chromium (VI).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... a specific process, operation, or activity involving chromium cannot release dusts, fumes, or mists... 29 Labor 7 2014-07-01 2014-07-01 false Chromium (VI). 1915.1026 Section 1915.1026 Labor... § 1915.1026 Chromium (VI). (a) Scope. (1) This standard applies to occupational exposures to chromium (VI...

  8. Welding and brazing of nickel and nickel-base alloys

    NASA Technical Reports Server (NTRS)

    Mortland, J. E.; Evans, R. M.; Monroe, R. E.

    1972-01-01

    The joining of four types of nickel-base materials is described: (1) high-nickel, nonheat-treatable alloys, (2) solid-solution-hardening nickel-base alloys, (3) precipitation-hardening nickel-base alloys, and (4) dispersion-hardening nickel-base alloys. The high-nickel and solid-solution-hardening alloys are widely used in chemical containers and piping. These materials have excellent resistance to corrosion and oxidation, and retain useful strength at elevated temperatures. The precipitation-hardening alloys have good properties at elevated temperature. They are important in many aerospace applications. Dispersion-hardening nickel also is used for elevated-temperature service.

  9. Treatment of chromium contaminated soil using bioremediation

    NASA Astrophysics Data System (ADS)

    Purwanti, Ipung Fitri; Putri, Tesya Paramita; Kurniawan, Setyo Budi

    2017-11-01

    Chromium contamination in soil occurs due to the disposal of chromium industrial wastewater or sludge that excess the quality standard. Chromium concentration in soil is ranged between 1 to 300 mg/kg while the maximum health standard is 2.5 mg/kg. Bioremediation is one of technology that could be used for remediating heavy metal contamination in soil. Bacteria have an ability to remove heavy metal from soil. One bacteria species that capable to remove chromium from soil is Bacillus subtilis. The aim of this research was to know the chromium removal percentage in contaminated soil by Bacillus subtilis. Artificial chromium contaminated soil was used by mixing 425gram sand and chromium trichloride solution. Concentration of chromium added into the spiked soil were 50, 75, and 100 mg/L. During 14 days, pH, soil temperature and soil moisture were tested. Initial and final number of bacterial colony and chromium concentration analysed. The result showed that the highest percentage of chromium removal was 11% at a chromium concentration of 75 mg/L

  10. Embrittlement of nickel-, cobalt-, and iron-base superalloys by exposure to hydrogen

    NASA Technical Reports Server (NTRS)

    Gray, H. R.

    1975-01-01

    Five nickel-base alloys (Inconel 718, Udimet 700, Rene 41, Hastelloy X, and TD-NiCr), one cobalt-base alloy (L-605), and an iron-base alloy (A-286) were exposed in hydrogen at 0.1 MN/sq m (15 psi) at several temperatures in the range from 430 to 980 C for as long as 1000 hours. These alloys were embrittled to varying degrees by such exposures in hydrogen. Embrittlement was found to be: (1) sensitive to strain rate, (2) reversible, (3) caused by large concentrations of absorbed hydrogen, and (4) not associated with any detectable microstructural changes in the alloys. These observations are consistent with a mechanism of internal reversible hydrogen embrittlement.

  11. Occurrences, uses, and properties of chromium.

    PubMed

    Barnhart, J

    1997-08-01

    Chromium is the 21st most abundant element in the Earth's crust with a mean concentration in United States soils of about 40 mg/kg. Although it exists in several oxidation states, the zero, trivalent, and hexavalent states are the most important in commercial products and the environment. Nearly all naturally occurring chromium is in the trivalent state, usually in combination with iron or other metal oxides. Although only about 15% of the chromium mined is used in the manufacture of chemicals, most applications of chromium utilize the chemistry of chromium. For instance, the "stainless" nature of stainless steel is due to the chemical properties of the chromium oxides which form on the surface of the alloy. Similarly, the protective properties of chrome plating of metals, chromated copper arsenate (CCA) treatment of wood, and chrome tanning of leather are all dependent on chromium chemistry. The key to these uses is that under typical environmental and biological conditions of pH and oxidation-reduction potential, the most stable form of chromium is the trivalent oxide. This form has very low solubility and low reactivity resulting in low mobility in the environment and low toxicity in living organisms. In this paper the chemical properties of chromium are discussed for the major commercial products in the context of the Eh-pH diagram for chromium. Copyright 1997 Academic Press.

  12. Composition optimization of chromium carbide based solid lubricant coatings for foil gas bearings at temperatures to 650 C

    NASA Technical Reports Server (NTRS)

    Dellacorte, Christopher

    1987-01-01

    A test program to determine the optimum composition of chromium carbide based solid lubricant coatings for compliant gas bearings is described. The friction and wear properties of the coatings are evaluated using a foil gas bearing test apparatus. The various coatings were prepared by powder blending, then plasma sprayed onto Inconel 718 test journals and diamond ground to the desired coating thickness and surface finish. The journals were operated against preoxidized nickel-chromium alloy foils. The test bearings were subjected to repeated start/stop cycles under a 14 kPa (2 psi) bearing unit load. The bearings were tested for 9000 start/stop cycles or until the specimen wear reached a predetermined failure level. In general, the addition of silver and eutectic to the chromium carbide base stock significantly reduced foil wear and increased journal coating wear. The optimum coating composition, PS212 (70 wt% metal bonded Cr3C2, 15 wt% Ag, 15% BaF2/CaF2 eutectic), reduced foil wear by a factor of two and displayed coating wear well within acceptable limits. The load capacity of the bearing using the plasma-sprayed coating prior to and after a run-in period was ascertained and compared to polished Inconel 718 specimens.

  13. Unexpected formation of chiral pincer CNN nickel complexes with β-diketiminato type ligands via C-H activation: synthesis, properties, structures, and computational studies.

    PubMed

    Lu, Zhengliang; Abbina, Srinivas; Sabin, Jared R; Nemykin, Victor N; Du, Guodong

    2013-02-04

    Reaction of lithiated chiral, unsymmetric β-diketimine type ligands HL(2a-e) containing oxazoline moiety (HL(2a-e) = 2-(2'-R(1)NH)-phenyl-4-R(2)-oxazoline) with trans-NiCl(Ph)(PPh(3))(2) afforded a series of new chiral CNN pincer type nickel complexes (3a-3e) via an unexpected cyclometalation at benzylic or aryl C-H positions. Single crystal X-ray diffraction analysis established the pincer coordination mode and the strained conformation. Chirality, and in one case, racemization of the target nickel complexes were confirmed by circular dichroism (CD) spectroscopy. Electronic structure and band assignments in experimental UV-vis and CD spectra were discussed on the basis of Density Functional Theory (DFT) and time-dependent (TD) DFT calculations.

  14. TD-1792 versus Vancomycin for Treatment of Complicated Skin and Skin Structure Infections

    PubMed Central

    Potgieter, Peter D.; Li, Yu-Ping; Barriere, Steven L.; Churukian, Allan; Kingsley, Jeff; Corey, G. Ralph

    2012-01-01

    TD-1792 is a first-in-class glycopeptide-cephalosporin heterodimer that exhibits bactericidal activity against Gram-positive pathogens. We conducted a randomized, double-blind, active-control, phase II trial in patients with complicated skin and skin structure infections caused by suspected or confirmed Gram-positive organisms. Patients 18 to 65 years old were randomized to receive 7 to 14 days of either TD-1792 (2 mg/kg of body weight intravenously [i.v.] every 24 h [q24h]) or vancomycin (1 g i.v. q12h, with dosage regimens adjusted per site-specific procedures). A total of 197 patients were randomized and received at least one dose of study medication. Rates of clinical success at the test-of-cure evaluation were similar in all analysis populations. Among 170 clinically evaluable patients, cure rates were 91.7% and 90.7% in the TD-1792 and vancomycin groups, respectively (95% confidence interval [CI] of −7.9 to 9.7 for the difference). In microbiologically evaluable patients with methicillin-resistant Staphylococcus aureus at baseline (n = 75), cure rates were 94.7% in the TD-1792 group and 91.9% in the vancomycin group. Microbiological eradication of Gram-positive pathogens (n = 126) was achieved in 93.7% and 92.1% of patients in the TD-1792 and vancomycin groups, respectively. Seven patients were discontinued from study medication due to an adverse event (AE): 2 and 5 in the TD-1792 and vancomycin groups, respectively. AEs were of similar types and severities between the two groups, other than pruritus, which was more common in patients who received vancomycin. No patients in the TD-1792 group experienced a serious AE. This study supports further clinical development of TD-1792 in patients with Gram-positive infection. PMID:22869571

  15. 75 FR 49023 - Proposed Collection; Comment Request for Form TD F 90-22.1

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-12

    ... TD F 90-22.1 AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Notice and request for... Form TD F 90-22.1, Report of Foreign Bank and Financial Accounts. DATES: Written comments should be.... OMB Number: 1545-2038. Form Number: TD F 90-22.1. Abstract: This information is collected because of...

  16. Preliminary Material Properties Handbook. Volume 1: English Units

    DTIC Science & Technology

    2000-07-01

    6-1 6.2 Iron- Chromium -Nickel-Base Alloys...titanium but is stabilized to room temperature by sufficient quantities of beta stabilizing elements as vanadium, molybdenum, iron, or chromium . In...Designation 6.2 6.3 6.3.1 6.3.2 6.3.3 6.3.4 6.3.5 6.4 6.5 6.5.1 Iron- Chromium -Nickel-Base Alloys Nickel-Base Alloys AEREX® 350 alloy HAYNES® 230® alloy

  17. Earliest humans in Europe: The age of TD6 Gran Dolina, Atapuerca, Spain

    USGS Publications Warehouse

    Falgueres, Christophe; Bahain, J.-J.; Yokoyama, Y.; Arsuaga, J.L.; Bermudez de Castro, Jose Maria; Carbonell, E.; Bischoff, J.L.; Dolo, J.-M.

    1999-01-01

    Hominid remains found in 1994 from the stratified Gran Dolina karst-filling at the Atapuerca site in NE Spain were dated to somewhat greater than 780 ka based on palaeomagnetic measurements, making these the oldest known hominids in Europe (sensu stricto). We report new ESR and U-series results on teeth from four levels of the Gran Dolina deposit which confirm the palaeomagnetic evidence, and indicate that TD6 (from which the human remains have been recovered) dates to the end of the Early Pleistocene. The results for the other levels are consistent with estimates based mainly on microfaunal evidence, and suggest that TD8, TD10 and TD11 date to the Middle Pleistocene. (C) 1999 Academic Press.

  18. 40 CFR 437.44 - Effluent limitations attainable by the application of the best available technology economically...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Antimony Arsenic Cadmium Chromium Cobalt Copper Lead Mercury Nickel Silver Tin Titanium Vanadium Zinc (2... Lead Mercury Nickel Silver Tin Titanium Vanadium Zinc (2) The in-plant limitations that apply to metal... parameters Antimony Arsenic Cadmium Chromium Cobalt Copper Lead Mercury Nickel Silver Tin Titanium Vanadium...

  19. 40 CFR 437.44 - Effluent limitations attainable by the application of the best available technology economically...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Antimony Arsenic Cadmium Chromium Cobalt Copper Lead Mercury Nickel Silver Tin Titanium Vanadium Zinc (2... Lead Mercury Nickel Silver Tin Titanium Vanadium Zinc (2) The in-plant limitations that apply to metal... parameters Antimony Arsenic Cadmium Chromium Cobalt Copper Lead Mercury Nickel Silver Tin Titanium Vanadium...

  20. 40 CFR 437.44 - Effluent limitations attainable by the application of the best available technology economically...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Antimony Arsenic Cadmium Chromium Cobalt Copper Lead Mercury Nickel Silver Tin Titanium Vanadium Zinc (2... Lead Mercury Nickel Silver Tin Titanium Vanadium Zinc (2) The in-plant limitations that apply to metal... parameters Antimony Arsenic Cadmium Chromium Cobalt Copper Lead Mercury Nickel Silver Tin Titanium Vanadium...

  1. 40 CFR 437.44 - Effluent limitations attainable by the application of the best available technology economically...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Antimony Arsenic Cadmium Chromium Cobalt Copper Lead Mercury Nickel Silver Tin Titanium Vanadium Zinc (2... Lead Mercury Nickel Silver Tin Titanium Vanadium Zinc (2) The in-plant limitations that apply to metal... parameters Antimony Arsenic Cadmium Chromium Cobalt Copper Lead Mercury Nickel Silver Tin Titanium Vanadium...

  2. 40 CFR 437.44 - Effluent limitations attainable by the application of the best available technology economically...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Antimony Arsenic Cadmium Chromium Cobalt Copper Lead Mercury Nickel Silver Tin Titanium Vanadium Zinc (2... Lead Mercury Nickel Silver Tin Titanium Vanadium Zinc (2) The in-plant limitations that apply to metal... parameters Antimony Arsenic Cadmium Chromium Cobalt Copper Lead Mercury Nickel Silver Tin Titanium Vanadium...

  3. The influence of chromium on structure and mechanical properties of B2 nickel aluminide alloys. Ph.D. Thesis - Florida Univ., 1991 Final Report

    NASA Technical Reports Server (NTRS)

    Cotton, James Dean

    1992-01-01

    Major obstacles to the use of NiAl-based alloys and composites are low ductility and toughness. These shortcomings result in part from a lack of sufficient slip systems to accommodate plastic deformation of polycrystalline material (von Mises Criterion). It has been reported that minor additions of chromium to polycrystalline NiAl cause the predominant slip system to shift from the usual. If true, then a major step toward increasing ductility in this compound may be realized. The purpose of the present study was to verify this phenomenon, characterize it with respect to chromium level and Ni to Al ratio, and correlate any change in slip system with microstructure and mechanical properties. Compression and tensile specimens were prepared from alloys containing 0 to 5 percent chromium and 45 to 55 percent aluminum. Following about one percent strain, transmission electron microscopy foils were produced and the slip systems determined using the g x b = 0 invisibility criterion. Contrary to previous results, chromium was found to have no effect on the preferred slip system of any of the alloys studied. Possible reasons for the inconsistency of the current results with previous work are considered. Composition-structure-property relationships are discerned for the alloys, and good correlation are demonstrated in terms of conventional strengthening models for metallic systems.

  4. Effects of silver and group 2 fluorides addition to plasma sprayed chromium carbide high temperature solid lubricant for foil gas bearing to 650 deg C

    NASA Technical Reports Server (NTRS)

    Wagner, R. C.; Sliney, H. E.

    1984-01-01

    A new self-lubricating coating composition of nickel aluminide-bonded chromium carbide formulated with silver and Group II fluorides was developed in a research program on high temperature solid lubricants. One of the proposed applications for this new coating composition is as a wide temperature spectrum solid lubricant for complaint foil gas bearings. Friction and wear properties were obtained using a foil gas bearing start/stop apparatus at temperatures from 25 to 650 C. The journals were Inconel 718. Some were coated with the plasma sprayed experimental coating, others with unmodified nickel aluminide/chromium carbide as a baseline for comparison. The addtitional components were provided to assist in achieving low friction over the temperature range of interest. Uncoated, preoxidized Inconel X-750 foil bearings were operated against these surfaces. The foils were subjected to repeated start/stop cycles under a 14-kPa (2-psi) bearing unit loading. Sliding contact occurred during lift-off and coastdown at surface velocities less than 6 m/s (3000 rpm). Testing continued until 9000 start/stop cycles were accumulated or until a rise in starting torque indicated the journal/bearing had failed. Comparison in coating performance as well as discussions of their properties and methods of application are given.

  5. Levels and predictors of airborne and internal exposure to chromium and nickel among welders--results of the WELDOX study.

    PubMed

    Weiss, Tobias; Pesch, Beate; Lotz, Anne; Gutwinski, Eleonore; Van Gelder, Rainer; Punkenburg, Ewald; Kendzia, Benjamin; Gawrych, Katarzyna; Lehnert, Martin; Heinze, Evelyn; Hartwig, Andrea; Käfferlein, Heiko U; Hahn, Jens-Uwe; Brüning, Thomas

    2013-03-01

    The objective of this analysis was to investigate levels and determinants of exposure to airborne and urinary chromium (Cr, CrU) and nickel (Ni, NiU) among 241 welders. Respirable and inhalable welding fume was collected during a shift, and the metal content was determined using inductively coupled plasma mass spectrometry. In post-shift urine, CrU and NiU were measured by means of graphite furnace atom absorption spectrometry, with resulting concentrations varying across a wide range. Due to a large fraction below the limits of quantitation we applied multiple imputations to the log-transformed exposure variables for the analysis of the data. Respirable Cr and Ni were about half of the concentrations of inhalable Cr and Ni, respectively. CrU and NiU were determined with medians of 1.2 μg/L (interquartile range <1.00; 3.61) and 2.9 μg/L (interquartile range <1.50; 5.97). Furthermore, Cr and Ni correlated in respirable welding fume (r=0.79, 95% CI 0.74-0.85) and urine (r=0.55, 95% CI 0.44-0.65). Regression models identified exposure-modulating variables in form of multiplicative factors and revealed slightly better model fits for Cr (R(2) respirable Cr 48%, CrU 55%) than for Ni (R(2) respirable Ni 42%, NiU 38%). The air concentrations were mainly predicted by the metal content in electrodes or base material in addition to the welding technique. Respirable Cr and Ni were good predictors for CrU and NiU, respectively. Exposure was higher when welding was performed in confined spaces or with inefficient ventilation, and lower in urine when respirators were used. In conclusion, statistical modelling allowed the evaluation of determinants of internal and external exposure to Cr and Ni in welders. Welding parameters were stronger predictors than workplace conditions. Airborne exposure was lowest inside respirators with supply of purified air. Copyright © 2012 Elsevier GmbH. All rights reserved.

  6. Preliminary Material Properties Handbook, English Units

    DTIC Science & Technology

    1999-12-01

    References 5-17 Chapter 6. Heat-Resistant Alloys 6.1 General 6-1 6.2 Iron- Chromium -Nickel-Base Alloys 6-3 6.3 Nickel-Base Alloys 6-3 6.4...elements as vanadium, molybdenum, iron, or chromium . In addition to strengthening of titanium by the alloying additions, alpha-beta alloys may be...alloys are arbitrarily defined as iron alloys richer in alloy content than the 18 percent chromium , 8 percent nickel types, or as alloys with a base

  7. Intentionally Designed Three-Phase Time Diary (TD) as a Multi-Pronged Practice

    ERIC Educational Resources Information Center

    Chen, Hsin-Yu; Yarnal, Careen

    2017-01-01

    Adopting qualitative approaches, this study highlights the value of integrating cognitive understanding with students' daily experiences through a time diary (TD) project. Using an innovative three-phase design, the TD effectively heightened self-awareness, promoted self-reflection, inspired the desire to change, and facilitated knowledge…

  8. Efficient Separation and Extraction of Vanadium and Chromium in High Chromium Vanadium Slag by Selective Two-Stage Roasting-Leaching

    NASA Astrophysics Data System (ADS)

    Wen, Jing; Jiang, Tao; Xu, Yingzhe; Liu, Jiayi; Xue, Xiangxin

    2018-06-01

    Vanadium and chromium are important rare metals, leading to a focus on high chromium vanadium slag (HCVS) as a potential raw material to extract vanadium and chromium in China. In this work, a novel method based on selective two-stage roasting-leaching was proposed to separate and extract vanadium and chromium efficiently in HCVS. XRD, FT-IR, and SEM were utilized to analyze the phase evolutions and microstructure during the whole process. Calcification roasting, which can calcify vanadium selectively using thermodynamics, was carried out in the first roasting stage to transfer vanadium into acid-soluble vanadate and leave chromium in the leaching residue as (Fe0.6Cr0.4)2O3 after H2SO4 leaching. When HCVS and CaO were mixed in the molar ratio CaO/V2O3 (n(CaO)/n(V2O3)) of 0.5 to 1.25, around 90 pct vanadium and less than 1 pct chromium were extracted in the first leaching liquid, thus achieving the separation of vanadium and chromium. In the second roasting stage, sodium salt, which combines with chromium easily, was added to the first leaching residue to extract chromium and 95.16 pct chromium was extracted under the optimal conditions. The total vanadium and chromium leaching rates were above 95 pct, achieving the efficient separation and extraction of vanadium and chromium. The established method provides a new technique to separate vanadium and chromium during roasting rather than in the liquid form, which is useful for the comprehensive application of HCVS.

  9. Efficient Separation and Extraction of Vanadium and Chromium in High Chromium Vanadium Slag by Selective Two-Stage Roasting-Leaching

    NASA Astrophysics Data System (ADS)

    Wen, Jing; Jiang, Tao; Xu, Yingzhe; Liu, Jiayi; Xue, Xiangxin

    2018-04-01

    Vanadium and chromium are important rare metals, leading to a focus on high chromium vanadium slag (HCVS) as a potential raw material to extract vanadium and chromium in China. In this work, a novel method based on selective two-stage roasting-leaching was proposed to separate and extract vanadium and chromium efficiently in HCVS. XRD, FT-IR, and SEM were utilized to analyze the phase evolutions and microstructure during the whole process. Calcification roasting, which can calcify vanadium selectively using thermodynamics, was carried out in the first roasting stage to transfer vanadium into acid-soluble vanadate and leave chromium in the leaching residue as (Fe0.6Cr0.4)2O3 after H2SO4 leaching. When HCVS and CaO were mixed in the molar ratio CaO/V2O3 (n(CaO)/n(V2O3)) of 0.5 to 1.25, around 90 pct vanadium and less than 1 pct chromium were extracted in the first leaching liquid, thus achieving the separation of vanadium and chromium. In the second roasting stage, sodium salt, which combines with chromium easily, was added to the first leaching residue to extract chromium and 95.16 pct chromium was extracted under the optimal conditions. The total vanadium and chromium leaching rates were above 95 pct, achieving the efficient separation and extraction of vanadium and chromium. The established method provides a new technique to separate vanadium and chromium during roasting rather than in the liquid form, which is useful for the comprehensive application of HCVS.

  10. Nickel and manganese transfer from soil to plant in lateritic mining soils from New Caledonia

    NASA Astrophysics Data System (ADS)

    Pouschat, P.; Rose, J.; Alliot, I.; Dominici, C.; Keller, C.; Laffont-Schwob, I.; Olivi, L.; Ambrosi, J.-P.

    2009-04-01

    New Caledonian ferritic soils (more than 50 % of iron) are naturally rich in metals (chromium, nickel, cobalt, and manganese), deficient in major nutrients (nitrogen, phosphorous, and potassium), and unbalanced for the calcium/magnesium ratio. Under these particular ecological conditions, New Caledonia, recognized as a hot-spot of biodiversity, is a natural laboratory to study and understand the adaptation strategies of plants to metalliferous soils, and particularly the tolerance and (hyper)accumulation of metals by plants. Moreover, understanding such mechanisms is essential to develop rehabilitation or phytoremediation techniques for polluted soils, as well as phytomining techniques. Thus, in order to understand the soil - plant relationship and metal mobility along a toposequence in a future nickel mining massif, field experiments were conducted in an isolated ultramafic massif of New Caledonia. Several plant species of two endemic and frequent plant genera were chosen: Tristaniopsis guillainii and T. calobuxus (Myrtaceae), and Phyllanthus serpentinus and P. favieri (Euphorbiaceae), because of their nickel and/or manganese accumulating or hyperaccumulating nature. Leaves, twigs, and roots of all plants were collected along the soil sequence and their associated rhizospheric and bulk soils were sampled. Next, a series of characterization techniques were adapted and then coupled to cryogenics. The combined use of those multiple techniques (cryo-microtomy, cryo-SEM, µXRF, cryo-XAS, and soil characterization) allowed to study co-location and speciation of nickel and manganese in the different plant organs and soils (rhizospheric and bulk). Bioaccumulated nickel and manganese had different distribution patterns. In leaves, Ni accumulated in non photosynthetic tissues (e.g. epidermis) whereas Mn preferentially accumulated in mesophyll whatever the plant species. Nevertheless, in spite of a different speciation in soils, nickel and manganese were both found as

  11. The Effect of Artificial Aging on The Bond Strength of Heat-activated Acrylic Resin to Surface-treated Nickel-chromium-beryllium Alloy.

    PubMed

    Al Jabbari, Youssef S; Zinelis, Spiros; Al Taweel, Sara M; Nagy, William W

    2016-01-01

    The debonding load of heat-activated polymethylmethacrylate (PMMA) denture base resin material to a nickel-chromium-beryllium (Ni-Cr-Be) alloy conditioned by three different surface treatments and utilizing two different commercial bonding systems was investigated. Denture resin (Lucitone-199) was bonded to Ni-Cr-Be alloy specimens treated with Metal Primer II, the Rocatec system with opaquer and the Rocatec system without opaquer. Denture base resin specimens bonded to non-treated sandblasted Ni-Cr-Be alloy were used as controls. Twenty samples for each treatment condition (80 specimens) were tested. The 80 specimens were divided into two categories, thermocycled and non-thermocycled, containing four groups of ten specimens each. The non-thermocycled specimens were tested after 48 hours' storage in room temperature water. The thermocycled specimens were tested after 2,000 cycles in 4°C and 55°C water baths. The debonding load was calculated in Newtons (N), and collected data were subjected by non parametric test Kruskal-Wallis One Way Analysis of Variance on Ranks and Dunn's post hoc test at the α = 0.05. The Metal Primer II and Rocatec system without opaquer groups produced significantly higher bond strengths (119.9 and 67.6 N), respectively, than did the sandblasted and Rocatec system with opaquer groups, where the bond strengths were 2.6 N and 0 N, respectively. The Metal Primer II was significantly different from all other groups (P<0.05). The bond strengths of all groups were significantly decreased (P<0.05) after thermocycling. Although thermocycling had a detrimental effect on the debonding load of all surface treatments tested, the Metal Primer II system provided higher values among all bonding systems tested, before and after thermocycling.

  12. Urinary chromium concentrations in humans following ingestion of safe doses of hexavalent and trivalent chromium: Implications for biomonitoring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Finley, B.L.; Scott, P.K.; Norton, R.L.

    1996-08-09

    This study evaluates the significance of increased urinary chromium concentrations as a marker of chromium exposure and potential health risk. Six human volunteers ingested trivalent chromium [Cr(III)] and hexavalent chromium [Cr(VI)] at doses that are known to be safe but higher than typical levels. The following dosing regimen was used: d 1-7, 200 {mu}g/d chromium picolinate; d 8-10, Cr(VI) ingestion at the U.S. Environmental Protection Agency (EPA) reference dose (RfD) of 0.005 mg/kg/d; d 11-13, no dose; d 14-16, Cr(III) ingestion at the U.S. EPA RfD of 1.0 mg/kg/d; and 17-18, postdose. Findings are as follows: (1) ingestion of 200more » {mu}g/d of chromium picolinate yielded significantly elevated urine concentrations such that each participant routinely exceeded background, (2) ingestion of the Cr(VI) RfD (0.005 mg/kg/d) yielded individual mean urinary chromium levels (1.2-2.3 {mu}g/L) and a pooled mean urinary chromium level (2.4 {mu}g/L) that significantly exceeded background, and (3) ingestion of the Cr(III) RfD yielded no significantly exceeded background, and (3) ingestion of the Cr(III) RfD yielded no significant increase in urinary chromium concentrations, indicating that little, if any, absorption occurred. Our work identified three critical issues that need to be accounted for in any future studies that will use urinary chromium as a marker of exposure. First, a minimum urinary chromium concentration of approximately 2 {mu}g/L should be used as a screening level to critically identify individuals who may have experienced elevated exposures to chromium. Second, if Cr(III) levels in soils are known to be less than 80,000 ppm and the Cr(III) is insoluble, urinary chromium concentrations are not an appropriate marker of exposure. Third, newer forms of chromium supplements that contain organic forms of Cr(III) must be considered potential confounders and their contribution to residential chromium uptake must be carefully evaluated. 19 refs., 7 figs., 3

  13. Health assessment for Stamina Mills Site, North Smithfield, Providence County, Rhode Island, Region 1. CERCLIS No. RID980731442. Preliminary report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1988-11-15

    The Stamina Mills site is on the National Priorities List (NPL). The environmental contamination of concern consists of methylene chloride, chromium, lead, nickel, trichloroethylene, perchloroethylene, and 1,2-dichloro- ethylene in groundwater; trichloroethylene, 1,2-dichloroethylene, methylene chloride, and nickel in surface water; trichloroethylene, 1,2-dichloroethylene, chloroform, methylene chloride, cyanide, 2-butanone, cadmium, lead, chromium, nickel, and dieldrin in soil; and chloroform, lead, nickel, and chromium in sediment. The site is considered to be of potential public health concern because of the risk to human health caused by the possibility of exposure to hazardous substances via soil, sediment, and surface water.

  14. 75 FR 47893 - Proposed Collection; Comment Request for REG-111583-07, (T.D. 9405) (Final)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-09

    ...-111583-07, (T.D. 9405) (Final) AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Notice and... comments concerning temporary and final regulations (REG-111583-07) (T.D. 9405), Employment Tax Adjustments... Adjustments. OMB Number: 1545-2097. Form Number: REG-111583-07 (T.D. 9405) (final). Abstract: This document...

  15. Analysis of thermoelectric properties of high-temperature complex alloys of nickel-base, iron-base and cobalt-base groups

    NASA Technical Reports Server (NTRS)

    Holanda, R.

    1984-01-01

    The thermoelectric properties alloys of the nickel-base, iron-base, and cobalt-base groups containing from 1% to 25% 106 chromium were compared and correlated with the following material characteristics: atomic percent of the principle alloy constituent; ratio of concentration of two constituents; alloy physical property (electrical resistivity); alloy phase structure (percent precipitate or percent hardener content); alloy electronic structure (electron concentration). For solid-solution-type alloys the most consistent correlation was obtained with electron concentration, for precipitation-hardenable alloys of the nickel-base superalloy group, the thermoelectric potential correlated with hardener content in the alloy structure. For solid-solution-type alloys, no problems were found with thermoelectric stability to 1000; for precipitation-hardenable alloys, thermoelectric stability was dependent on phase stability. The effects of the compositional range of alloy constituents on temperature measurement uncertainty are discussed.

  16. Biodegradation of Orthodontic Appliances and Their Effects on the Blood Level of Nickel and Chromium

    DTIC Science & Technology

    1990-05-01

    production of stainless steels and other nickel alloys used for electroplating, battery manufacturing, in catalysts, coins and inorganic pigments . 1...as stainless steel, electroplating as a protective coating on other metals, in catalysts, in pigments , as a tanning agent for leather, textile...the earth’s crust. Titanium is 5 extensively used as a white pigment in paint, plastics and paper, in food as a coloring agent, in cosmetics and

  17. Review of FD-TD numerical modeling of electromagnetic wave scattering and radar cross section

    NASA Technical Reports Server (NTRS)

    Taflove, Allen; Umashankar, Korada R.

    1989-01-01

    Applications of the finite-difference time-domain (FD-TD) method for numerical modeling of electromagnetic wave interactions with structures are reviewed, concentrating on scattering and radar cross section (RCS). A number of two- and three-dimensional examples of FD-TD modeling of scattering and penetration are provided. The objects modeled range in nature from simple geometric shapes to extremely complex aerospace and biological systems. Rigorous analytical or experimental validatons are provided for the canonical shapes, and it is shown that FD-TD predictive data for near fields and RCS are in excellent agreement with the benchmark data. It is concluded that with continuing advances in FD-TD modeling theory for target features relevant to the RCS problems and in vector and concurrent supercomputer technology, it is likely that FD-TD numerical modeling will occupy an important place in RCS technology in the 1990s and beyond.

  18. Method for decontamination of nickel-fluoride-coated nickel containing actinide-metal fluorides

    DOEpatents

    Windt, N.F.; Williams, J.L.

    In one aspect, the invention comprises contacting nickel-fluoride-coated nickel with gaseous ammonia at a temperature effecting nickel-catalyzed dissociation thereof and effecting hydrogen-reduction of the nickel fluoride. The resulting nickel is heated to form a melt and a slag and to effect transfer of actinide metals from the melt into the slag. The melt and slag are then separated. In another aspect, nickel contianing nickel oxide and actinide metals is contacted with ammonia at a temperature effecting nickel-catalyzed dissociation to effect conversion of the nickel oxide to the metal. The resulting nickel is then melted and separated as described. In another aspect nickel-fluoride-coated nickel containing actinide-metal fluorides is contacted with both steam and ammonia. The resulting nickel then is melted and separated as described. The invention is characterized by higher nickel recovery, efficient use of ammonia, a substantial decrease in slag formation and fuming, and a valuable increase in the service life of the furnace liners used for melting.

  19. An improved diffusion welding technique for TD-NiCr

    NASA Technical Reports Server (NTRS)

    Holko, K. H.

    1973-01-01

    An improved diffusion welding technique has been developed for TD-NiCr sheet. In the most preferred form, the improved technique consists of diffusion welding 320-grit sanded plus chemically polished surfaces of unrecrystallized TD-NiCr at 760 C under 140 MN/m2 pressure for 1hr followed by postheating at 1180 C for 2hr. Compared to previous work, this improved technique has the advantages of shorter welding time, lower welding temperature, lower welding pressure, and a simpler and more reproducible surface preparation procedure. Weldments were made that had parent-metal creep-rupture shear strength at 1100 C.

  20. Method for decontamination of nickel-fluoride-coated nickel containing actinide-metal fluorides

    DOEpatents

    Windt, Norman F.; Williams, Joe L.

    1983-01-01

    The invention is a process for decontaminating particulate nickel contaminated with actinide-metal fluorides. In one aspect, the invention comprises contacting nickel-fluoride-coated nickel with gaseous ammonia at a temperature effecting nickel-catalyzed dissociation thereof and effecting hydrogen-reduction of the nickel fluoride. The resulting nickel is heated to form a melt and a slag and to effect transfer of actinide metals from the melt into the slag. The melt and slag are then separated. In another aspect, nickel containing nickel oxide and actinide metals is contacted with ammonia at a temperature effecting nickel-catalyzed dissociation to effect conversion of the nickel oxide to the metal. The resulting nickel is then melted and separated as described. In another aspect nickel-fluoride-coated nickel containing actinide-metal fluorides is contacted with both steam and ammonia. The resulting nickel then is melted and separated as described. The invention is characterized by higher nickel recovery, efficient use of ammonia, a substantial decrease in slag formation and fuming, and a valuable increase in the service life of the furnace liners used for melting.

  1. The National Shipbuilding Research Program. Shipyard Welding Emission Factor Development

    DTIC Science & Technology

    1999-09-01

    percent composition in the rod/wire. Three specific HAPs of concern were identified: 1. Chrome and chromium compounds; 2. Nickel and nickel compounds...welding processes. These are: 1. Those rod/wires reported to be used in the largest amounts (> 10,000 pounds annually) did not contain chromium or...amounts ranging from less than 1,000 to greater than 10,000 pounds annually contained chromium and chromium compounds in concentrations ranging from

  2. Chromium-induced kidney disease.

    PubMed

    Wedeen, R P; Qian, L F

    1991-05-01

    Kidney disease is often cited as one of the adverse effects of chromium, yet chronic renal disease due to occupational or environmental exposure to chromium has not yet been reported. Occasional cases of acute tubular necrosis (ATN) following massive absorption of chromate have been described. Chromate-induced ATN has been extensively studied in experimental animals following parenteral administration of large doses of potassium chromate (hexavalent) (15 mg/kg body weight). The chromate is selectively accumulated in the convoluted proximal tubule where necrosis occurs. An adverse long-term effect of low-dose chromium exposure on the kidneys is suggested by reports of low molecular weight (LMW) proteinuria in chromium workers. Excessive urinary excretion of beta 2-microglobulin, a specific proximal tubule brush border protein, and retinol-binding protein has been reported among chrome platers and welders. However, LMW proteinuria occurs after a variety of physiologic stresses, is usually reversible, and cannot by itself be considered evidence of chronic renal disease. Chromate-induced ATN and LMW proteinuria in chromium workers, nevertheless, raise the possibility that low-level, long-term exposure may produce persistent renal injury. The absence of evidence of chromate-induced exposure may produce persistent renal injury. The absence of evidence of chromate-induced chronic renal disease cannot be interpreted as evidence of the absence of such injury. Rather, it must be recognized that no prospective cohort or case-control study of the delayed renal effects of low-level, long-term exposure to chromium has been published.

  3. Chromium-induced skin damage among Taiwanese cement workers.

    PubMed

    Chou, Tzu-Chieh; Wang, Po-Chih; Wu, Jyun-De; Sheu, Shiann-Cherng

    2016-10-01

    Little research has been done on the relationships between chromium exposure, skin barrier function, and other hygienic habits in cement workers. Our purpose was to investigate chromium-induced skin barrier disruption due to cement exposure among cement workers. One hundred and eight cement workers were recruited in this study. Urinary chromium concentration was used to characterize exposure levels. The biological exposure index was used to separate high and low chromium exposure. Transepidermal water loss (TEWL) was used to assess the skin barrier function. TEWL was significantly increased in workers with high chromium exposure levels than those with low chromium exposure levels (p = 0.048). A positive correlation was also found between urinary chromium concentration and TEWL (R = 0.28, p = 0.004). After adjusting for smoking status and glove use, a significant correlation between urinary chromium concentrations and TEWL remained. Moreover, workers who smoked and had a high chromium exposure had significantly increased TEWL compared to nonsmokers with low chromium exposure (p = 0.01). Skin barrier function of cement workers may have been disrupted by chromium in cement, and smoking might significantly enhance such skin barrier perturbation with chromium exposure. Decreased chromium skin exposure and smoking cessation should be encouraged at work. © The Author(s) 2015.

  4. Diffusion of Chromium in Alpha Cobalt-Chromium Solid Solutions

    NASA Technical Reports Server (NTRS)

    Weeton, John W

    1951-01-01

    Diffusion of chromium in cobalt-chromium solid solutions was investigated in the range 0 to 40 atomic percent at temperatures of 1360 degrees, 1300 degrees, 1150 degrees, and 10000 degrees c. The diffusion coefficients were found to be relatively constant within the composition range covered by each specimen. The activation heat of diffusion was determined to be 63,000 calories per mole. This value agrees closely with the value of 63,400 calories per mole calculated by means of the Dushman-Langmuir equation.

  5. Lightweight nickel electrode for nickel hydrogen cells and batteries

    NASA Technical Reports Server (NTRS)

    Britton, D. L.

    1986-01-01

    The nickel electrode was identified as the heaviest component of the nickel hydrogen (NiH2) battery. The NASA Lewis Research Center is developing nickel electrodes for NiH2 battery devices which will be lighter in weight and have higher energy densities when cycled under a low Earth orbit regime at deep depths of discharge. Lightweight plaques are first exposed to 31 percent potassium hydroxide for 3 months to determine their suitability for use as electrode substrates from a chemical corrosion standpoint. Pore size distribution and porosity of the plaques are then measured. The lightweight plaques examined are nickel foam, nickel felt, nickel plastic and nickel plated graphite. Plaques are then electrochemically impregnated in an aqueous solution. Initial characterization tests of the impregnated plaques are performed at five discharge levels, C/2, 1.0 C, 1.37 C, 2.0C, and 2.74 C rates. Electrodes that passed the initial characterization screening test will be life cycle tested. Lightweight electrodes are approximately 30 to 50 percent lighter in weight than the sintered nickel electrode.

  6. Monoclonal antibody to trivalent chromium chelate complex and its application to measurement of the total chromium concentration.

    PubMed

    Sasaki, Kazuhiro; Oguma, Shinichi; Namiki, Yukie; Ohmura, Naoya

    2009-05-15

    Isothiocyanobenzyl group-appended ethylenediamine tetraacetic acid (EDTA) was used to covalently couple Cr(III) x EDTA to keyhole limpet hemocyanin for use as an immunogen. An obtained monoclonal antibody (RD3G4) bound to Cr(III) x EDTA with an equilibrium dissociation constant (K(d)) of 9.7 nM, which was 100-fold tighter than the K(d)s for the other tested EDTA-metal complex. In particular, there was an over 2000-fold affinity difference between Cr(III) x EDTA and Fe(III) x EDTA, although the ion radius of trivalent chromium (0.76 A) was quite close to that of ferric ion (0.79 A). Hexavalent chromium could be detected by the antibody after being reduced into trivalent form. An immunoassay format showed an IC50 of 87 nM for hexavalent chromium, with a detection limit of 30 nM (1.6 microg/L). Therefore, the addition of reducing agents to the mixture of tri- and hexavalent chromium allows determination of the total chromium concentration by the immunoassay. Hexavalent chromium could be isolated from trivalent chromium by an anion-exchange column, and thus, the concentration of hexavalent chromium in tri- and hexa- mixture can also be estimated by the immunoassay.

  7. Chromium Recycling in the United States in 1998

    USGS Publications Warehouse

    Papp, John F.

    2001-01-01

    The purpose of this report is to illustrate the extent to which chromium was recycled in the United States in 1998 and to identify chromium-recycling trends. The major use of chromium was in the metallurgical industry to make stainless steel; substantially less chromium was used in the refractory and chemical industries. In this study, the only chromium recycling reported was that which was a part of stainless steel scrap reuse. In 1998, 20 percent of the U.S. apparent consumption of chromium was secondary (from recycling); the remaining 80 percent was based on net chromium commodity imports and stock adjustments. Chromite ore was not mined in the United States in 1998. In 1998, 75,300 metric tons (t) of chromium contained in old scrap was consumed in the United States; it was valued at $66.4 million. Old scrap generated contained 132,000 t of chromium. The old scrap recycling efficiency was 87 percent, and the recycling rate was 20 percent. About 18,000 t of chromium in old scrap was unrecovered. New scrap consumed contained 28,600 t of chromium, which yielded a new-to-old-scrap ratio of 28:72. U.S. chromium-bearing stainless steel scrap net exports were valued at $154 million and were estimated to have contained 41,000 t of chromium.

  8. Reduction of hexavalent chromium collected on PVC filters.

    PubMed

    Shin, Y C; Paik, N W

    2000-01-01

    Chromium exists at various valences, including elemental, trivalent, and hexavalent chromium, and undergoes reduction-oxidation reactions in the environment. Since hexavalent chromium is known as a human carcinogen, it is most important to evaluate the oxidation-reduction characteristics of the hexavalent chromium species. Although hexavalent chromium can be reduced to trivalent state, the detailed information on this in workplace environments is limited. The purpose of this study was to investigate hexavalent chromium reduction in time in various conditions. A pilot chrome plating operation was prepared and operated in a laboratory for this study. There was evidence that the hexavalent chromium was reduced by time after mist generation. The percentage ratio (with 95% confidence intervals in parentheses) of hexavalent chromium to total chromium was almost 100% (99.1 approximately 102.3) immediately after mist generation, and was reduced to 87.4% (84.8 approximately 89.9) at 1 hour and 81.0% (78.3 approximately 83.5) at 2 hours, respectively. Another test indicated that hexavalent chromium collected on PVC filters was also reduced by time after sampling. Hexavalent chromium was reduced to 90.8% (88.2 approximately 93.3) at 2 hours after sampling. It also was found that hexavalent chromium was reduced during storage in air. It is recommended that air samples of hexavalent chromium be protected against reduction during storage.

  9. Chromium

    MedlinePlus

    ... determined because the content of the mineral in foods is substantially affected by agricultural and manufacturing processes and perhaps by contamination with chromium when the foods are analyzed [ 10 , ...

  10. Method of preparing a dimensionally stable electrode for use in a molten carbonate fuel cell

    DOEpatents

    Swarr, T.E.; Wnuck, W.G.

    1986-01-29

    A method is disclosed for preparing a dimensionally stable electrode structure, particularly nickel-chromium anodes, for use in a molten carbonate fuel cell stack. A low-chromium to nickel alloy is provided and oxidized in a mildly oxidizing gas of sufficient oxidation potential to oxidize chromium in the alloy structure. Typically, a steam/H/sub 2/ gas mixture in a ratio of about 100/1 and at a temperature below 800/sup 0/C is used as the oxidizing medium. This method permits the use of less than 5 wt % chromium in nickel alloy electrodes while obtaining good resistance to creep in the electrodes of a fuel cell stack.

  11. Method of preparing a dimensionally stable electrode for use in a MCFC

    DOEpatents

    Swarr, Thomas E.; Wnuck, Wayne G.

    1987-12-22

    A method is disclosed for preparing a dimensionally stable electrode structure, particularly nickel-chromium anodes, for use in a molten carbonate fuel cell stack. A low-chromium to nickel alloy is provided and oxidized in a mildly oxidizing gas of sufficient oxidation potential to oxidize chromium in the alloy structure. Typically, a steam/H.sub.2 gas mixture in a ratio of about 100/1 and at a temperature below 800.degree. C. is used as the oxidizing medium. This method permits the use of less than 5 weight percent chromium in nickel alloy electrodes while obtaining good resistance to creep in the electrodes of a fuel cell stack.

  12. 40 CFR 420.85 - Pretreatment standards for existing sources (PSES).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... daily values for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product Chromium 0.00292 0.00117... (pounds per 1,000 lb) of product Chromium 0.00175 0.000701 Nickel 0.00158 0.000526 (3) Batch, pipe and... Chromium 0.00709 0.00284 Nickel 0.00638 0.00213 (4) Continuous. Subpart H Pollutant or pollutant property...

  13. 40 CFR 420.103 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... of daily values for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product Chromium 1 0.0000209... 0.0000021 Tetrachloroethylene 0.0000031 1 The limitations for chromium and nickel shall be.../kkg (pounds per 1,000 lb) of product Chromium 1 0.000104 0.0000418 Lead 0.0000469 0.0000156 Nickel 1 0...

  14. 40 CFR 420.85 - Pretreatment standards for existing sources (PSES).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... daily values for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product Chromium 0.00292 0.00117... (pounds per 1,000 lb) of product Chromium 0.00175 0.000701 Nickel 0.00158 0.000526 (3) Batch, pipe and... Chromium 0.00709 0.00284 Nickel 0.00638 0.00213 (4) Continuous. Subpart H Pollutant or pollutant property...

  15. 40 CFR 420.85 - Pretreatment standards for existing sources (PSES).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... daily values for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product Chromium 0.00292 0.00117... (pounds per 1,000 lb) of product Chromium 0.00175 0.000701 Nickel 0.00158 0.000526 (3) Batch, pipe and... Chromium 0.00709 0.00284 Nickel 0.00638 0.00213 (4) Continuous. Subpart H Pollutant or pollutant property...

  16. Adverse Health Effects of Child Labor: High Exposure to Chromium and Oxidative DNA Damage in Children Manufacturing Surgical Instruments

    PubMed Central

    Sughis, Muhammad; Nawrot, Tim S.; Haufroid, Vincent

    2012-01-01

    Background: A considerable part of the worldwide production of surgical instruments takes place in Sialkot, Pakistan. Many children work in hazardous conditions in this industry. Objective: We investigated exposure to metals and possible health effects among children working in surgical instruments manufacturing units compared with schoolchildren from the same city. Methods: In a cross-sectional study we studied a convenience sample of 104 male children (10–14 years of age) working in surgical instruments manufacturing units and 75 male children of similar age from a school in Sialkot, Pakistan. A respiratory questionnaire was administered, spirometry was performed, and blood pressure was measured. In a spot urine sample, concentrations of metals were measured by inductively coupled plasma mass spectrometry and 8-hydroxydeoxyguanosine (8OHdG, reflecting oxidative DNA damage) by ELISA. Results: The working children reported more asthma (10% vs. 0%; p = 0.005) and dry cough at night (36% vs. 20%; p = 0.02) than did the schoolchildren, but there were no significant differences in pulmonary function or blood pressure. The urinary concentration of chromium was 35 times higher in working children [geometric mean, 23.0 µg/L; 25th–75th percentile, 8.38–58.6] than in schoolchildren [0.66 µg/L; 0.38–1.09)], and largely in excess of the occupational Biological Exposure Index for adult workers (25 µg/L). Urinary 8-OHdG concentrations were not significantly higher in working children than in schoolchildren (19.3 vs. 17.6 µg/g creatinine, p = 0.4), but were significantly correlated with urinary nickel (r = 0.41; p < 0.0001) and with a composite index of metal exposure (r = 0.46; p < 0.0001). Conclusions: Children working in the surgical instruments manufacturing industry had substantial exposure to several metals, especially chromium and nickel, which are established carcinogens. Exposure to nickel was associated with evidence of increased oxidative DNA damage. PMID

  17. Removing nickel from nickel-coated carbon fibers

    NASA Astrophysics Data System (ADS)

    Hardianto, A.; Hertleer, C.; De Mey, G.; Van Langenhove, L.

    2017-10-01

    Conductive fibers/yarns are one of the most important materials for smart textiles because of their electrically conductive functionality combined with flexibility and light weight. They can be applied in many fields such as the medical sector, electronics, sensors and even as thermoelectric generators. Temperature sensors, for example, can be made using the thermocouple or thermopile principle which usually uses two different metal wires that can produce a temperature-dependent voltage. However, if metal wires are inserted into a textile structure, they will decrease the flexibility properties of the textile product. Nickel-coated Carbon Fiber (NiCF), a conductive textile yarn, has a potential use as a textile-based thermopile if we can create an alternating region of carbon and nickel along the fiber which in turn it can be used for substituting the metallic thermopile. The idea was to remove nickel from NiCF in order to obtain a yarn that contains alternating zones of carbon and nickel. Due to no literature reporting on how to remove nickel from NiCF, in this paper we investigated some chemicals to remove nickel from NiCF.

  18. Characteristics of chromium-allergic dermatitis patients prior to regulatory intervention for chromium in leather: a questionnaire study.

    PubMed

    Bregnbak, David; Thyssen, Jacob P; Zachariae, Claus; Johansen, Jeanne D

    2014-12-01

    Chromium-tanned leather articles currently constitute the most important cause of contact allergy to chromium in Denmark. A regulation on the content of hexavalent chromium in leather was adopted in November 2013 by the EU member states. To characterize patients with chromium allergy and their disease, to serve as a baseline for future studies on the potential effect of the new regulation on chromium in leather. A questionnaire case-control study was performed on 155 dermatitis patients with positive patch test reactions to potassium dichromate and a matched control group of 621 dermatitis patients. Comparisons were made by use of a χ(2) -test and the Mann-Whitney U-test. Logistic regression analyses were used to test for associations. Sixty-six per cent of chromium-allergic patients had a positive history of contact dermatitis caused by leather exposure. They had a significantly lower quality of life (p < 0.001), a higher prevalence of dermatitis during the last year (p = 0.008), a higher use of medication during the past 12 months (p = 0.001) and a higher prevalence of sick leave (p = 0.007) than patients in the control group. Chromium-allergic patients have more severe and more chronic contact dermatitis. Their primary chromium exposure comes from leather articles. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Development and evaluation of the TD97 measles virus vaccine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Suzuki, K.; Morita, M.; Katoh, M.

    1990-11-01

    The TD97 strain vaccine virus was prepared from the Tanabe strain measles virus by low-temperature passages in primary cell cultures and ultraviolet (UV) mutagenesis. The TD97 strain exhibited the following characteristics: highly temperature sensitive, neither multiplying nor forming any plaques at 40 degrees C in Vero cells; genetically stable, maintaining high temperature sensitivity after ten successive passages in CE cells at 30 degrees C or 35 degrees C; and M proteins of this virus about 1 KD slower in mobility in SDS-PAGE than that of the Tanabe strain. The TD97 strain was further confirmed to be attenuated by an inoculationmore » test into primate brain. In field trials, 752 healthy children were inoculated with a live virus vaccine prepared with this strain, and the following results were obtained: the seroconversion rate was 97% (517/533), and the average HI antibody titer was 2(5.2). An antibody-increasing effect was also observed in children who were initially seropositive. In children who seroconverted, the rates of fever were 15.7% (55/351) for 37.5 degrees C or higher and 4.0% (14/351) for 39 degrees C or higher. The rash rate was 7.7% (27/351), and the incidence of local reaction was 5.4% (19/351). The TD97 strain is thus considered to be suitable in use for an attenuated measles vaccine.« less

  20. Monitoring of chromium and nickel in biological fluids of stainless steel welders using the flux-cored-wire (FCW) welding method.

    PubMed

    Stridsklev, Inger Cecilie; Schaller, Karl-Heinz; Langård, Sverre

    2004-11-01

    This study was undertaken to investigate the exposure to chromium (Cr) and nickel (Ni) in flux-cored wire (FCW) welders welding on stainless steel (SS). Seven FCW welders were monitored for 3 days to 1 workweek, measuring Cr and Ni in air, blood, and urine. The welders were questioned about exposure to Cr and Ni during their whole working careers, with emphasis on the week of monitoring, about the use of personal protective equipment and their smoking habits. The air concentrations were mean 200 microg/m(3) (range 2.4-2,744) for total Cr, 11.3 microg/m(3) (<0.2-151.3) for Cr(VI), and 50.4 microg/m(3) (<2.0-416.7) for Ni during the workdays for the five welders who were monitored with air measurements. The levels of Cr and Ni in biological fluids varied between different workplaces. For Cr in whole blood, plasma, and erythrocytes, the mean levels after work were 1.25 (<0.4-8.3) and 1.68 (<0.2-8.0) and 0.9 (<0.4-7.2) microg/l, respectively. For Ni most of the measurements in whole blood and plasma were below the detection limits, the mean levels after work being 0.84 (<0.8-3.3) and 0.57 microg/l (<0.4-1.7), respectively. Mean levels for Cr and Ni in the urine after work were 3.96 (0.34-40.7) and 2.50 (0.56-5.0) microg/g creatinine, respectively. Correlations between the Cr(VI) levels measured in air and the levels of total Cr in the measured biological fluids were found. The results seem to support the view that monitoring of Cr in the urine may be versatile for indirect monitoring of the Cr(VI) air level in FCW welders. The results seem to suggest that external and internal exposure to Cr and Ni in FCW welders welding SS is low in general.

  1. Chromium: a review of environmental and occupational toxicology.

    PubMed

    Bencko, V

    1985-01-01

    The following topics are covered in this brief review on the environmental and occupational toxicology of chromium: occurrence, production and uses of chromium and chromium compounds; experimental toxicology; chromium toxicity for man; hygienic and ecologic aspects of chromium contamination of the environment. The review provides a conclusive evidence which suggests that chromium, especially its hexavalent form, is both toxic and carcinogenic, but its trivalent form is physiologically essential in the metabolism of insulin. It is also emphasized that among the major sources of environmental chromium today are the cement industry and the increasingly widespread use of chromium compounds added as an anticorrosion admixture to a variety of cooling systems, e.g. in large power plants, which may greatly contribute to the overall pollution of outdoor air at the sites.

  2. 29 CFR 1926.1126 - Chromium (VI).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... is present or is likely to be present from skin or eye contact with chromium (VI), the employer shall... cleaned in a manner that minimizes skin or eye contact with chromium (VI) and effectively prevents the... CFR 1926.51 Where skin contact with chromium (VI) occurs, the employer shall provide washing...

  3. NICKEL PLATING PROCESS

    DOEpatents

    Hoover, T.B.; Zava, T.E.

    1959-05-12

    A simplified process is presented for plating nickel by the vapor decomposition of nickel carbonyl. In a preferred form of the invention a solid surface is nickel plated by subjecting the surface to contact with a mixture containing by volume approximately 20% nickel carbonyl vapor, 2% hydrogen sulfide and .l% water vapor or 1% oxygen and the remainder carbon dioxide at room temperature until the desired thickness of nickel is obtained. The advantage of this composition over others is that the normally explosive nickel carbonyl is greatly stabilized.

  4. Lightweight fibrous nickel electrodes for nickel-hydrogen batteries

    NASA Technical Reports Server (NTRS)

    Britton, Doris L.

    1989-01-01

    The NASA Lewis Research Center is currently developing nickel electrodes for nickel-hydrogen batteries. These electrodes are lighter in weight and have higher energy densities than the heavier state-of-the-art sintered nickel electrodes. Lightweight fibrous materials or plaques are used as conductive supports for the nickel hydroxide active material. These materials are commercial products that are fabricated into nickel electrodes by electrochemically impregnating them with active material. Evaluation is performed in half cells structured in the bipolar configuration. Initial performance tests include capacity measurements at five discharge levels, C/2, 1.0C, 1.37C, 2.0C, and 2.74C. The electrodes that pass the initial tests are life cycle-tested in a low Earth orbit regime at 80 percent depth of discharge.

  5. Determination of arsenic, cadmium, cobalt, chromium, lead, molybdenum, nickel, and selenium in fertilizers by microwave digestion and inductively coupled plasma-optical emission spectrometry detection: collaborative study.

    PubMed

    Kane, Peter F; Hall, William L

    2006-01-01

    There is increasing regulatory interest in the non-nutritive metals content of fertilizer materials, but at present there is no consensus analytical method for acid digestion and instrument detection of those elements in fertilizer matrixes. This lack of method standardization has resulted in unacceptable variability of results between fertilizer laboratories performing metals analysis. A method has been developed using microwave digestion with nitric acid at 200 degrees C, followed by inductively coupled plasma-optical emission spectrometry instrument detection, for the elements arsenic, cadmium, cobalt, chromium, molybdenum, nickel, lead, and selenium. The method has been collaboratively studied, and statistical results are here reported. Fourteen collaborators were sent 62 sample materials in a blind duplicate design. Materials represented a broad cross section of fertilizer types, including phosphate ore, manufactured phosphate products, N-P-K blends, organic fertilizers, and micro-nutrient materials. As much as possible within the limit of the number of samples, materials were selected from different regions of the United States and the world. Limit of detection (LOD) was determined using synthetic fertilizers consisting of reagent grade chemicals with near zero levels of the non-nutritive elements, analyzed blindly. Samples with high iron content caused the most variability between laboratories. Most samples reasonably above LOD gave HorRat values within the range 0.5 to 2.0, indicating acceptable method performance according to AOAC guidelines for analyses in the mg/kg range. The method is recommended for AOAC Official First Action status.

  6. 40 CFR 421.326 - Pretreatment standards for new sources.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... uranium processed in the refinery Chromium (total) 27.14 11.00 Copper 93.88 44.74 Nickel 40.34 27.14... uranium processed in the refinery Chromium (total) 1.689 0.685 Copper 5.844 2.785 Nickel 2.511 1.689... per million pounds) of uranium processed in the refinery Chromium (total) 2.357 0.955 Copper 8.152 3...

  7. 40 CFR 421.326 - Pretreatment standards for new sources.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... uranium processed in the refinery Chromium (total) 27.14 11.00 Copper 93.88 44.74 Nickel 40.34 27.14... uranium processed in the refinery Chromium (total) 1.689 0.685 Copper 5.844 2.785 Nickel 2.511 1.689... per million pounds) of uranium processed in the refinery Chromium (total) 2.357 0.955 Copper 8.152 3...

  8. 40 CFR 420.105 - Pretreatment standards for existing sources (PSES).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product Chromium 1 0.0000209 0.0000084 Lead 0... Tetrachloroethylene 0.0000031 1 The limitations for chromium and nickel shall be applicable in lieu of those for lead... (pounds per 1,000 lb) of product Chromium 1 0.000104 0.0000418 Lead 0.0000469 0.0000156 Nickel 1 0.0000939...

  9. 40 CFR 420.83 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Average of daily values for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product Chromium 0.00292 0... per 1,000 lb) of product Chromium 0.00175 0.000701 Nickel 0.00158 0.000526 (3) Batch, pipe and tube... values for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product Chromium 0.00709 0.00284 Nickel 0...

  10. 40 CFR 420.105 - Pretreatment standards for existing sources (PSES).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product Chromium 1 0.0000209 0.0000084 Lead 0... Tetrachloroethylene 0.0000031 1 The limitations for chromium and nickel shall be applicable in lieu of those for lead... (pounds per 1,000 lb) of product Chromium 1 0.000104 0.0000418 Lead 0.0000469 0.0000156 Nickel 1 0.0000939...

  11. 40 CFR 420.105 - Pretreatment standards for existing sources (PSES).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product Chromium 1 0.0000209 0.0000084 Lead 0... Tetrachloroethylene 0.0000031 1 The limitations for chromium and nickel shall be applicable in lieu of those for lead... (pounds per 1,000 lb) of product Chromium 1 0.000104 0.0000418 Lead 0.0000469 0.0000156 Nickel 1 0.0000939...

  12. 40 CFR 420.105 - Pretreatment standards for existing sources (PSES).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product Chromium 1 0.0000209 0.0000084 Lead 0... Tetrachloroethylene 0.0000031 1 The limitations for chromium and nickel shall be applicable in lieu of those for lead... (pounds per 1,000 lb) of product Chromium 1 0.000104 0.0000418 Lead 0.0000469 0.0000156 Nickel 1 0.0000939...

  13. 40 CFR 420.105 - Pretreatment standards for existing sources (PSES).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... for 30 consecutive days Kg/kkg (pounds per 1,000 lb) of product Chromium 1 0.0000209 0.0000084 Lead 0... Tetrachloroethylene 0.0000031 1 The limitations for chromium and nickel shall be applicable in lieu of those for lead... (pounds per 1,000 lb) of product Chromium 1 0.000104 0.0000418 Lead 0.0000469 0.0000156 Nickel 1 0.0000939...

  14. Cytotoxicity and oxidative mechanisms of different forms of chromium.

    PubMed

    Bagchi, Debasis; Stohs, Sidney J; Downs, Bernard W; Bagchi, Manashi; Preuss, Harry G

    2002-10-30

    Chromium exists mostly in two valence states in nature: hexavalent chromium [chromium(VI)] and trivalent chromium [chromium(III)]. Chromium(VI) is commonly used in industrial chrome plating, welding, painting, metal finishes, steel manufacturing, alloy, cast iron and wood treatment, and is a proven toxin, mutagen and carcinogen. The mechanistic cytotoxicity of chromium(VI) is not completely understood, however, a large number of studies demonstrated that chromium(VI) induces oxidative stress, DNA damage, apoptotic cell death and altered gene expression. Conversely, chromium(III) is essential for proper insulin function and is required for normal protein, fat and carbohydrate metabolism, and is acknowledged as a dietary supplement. In this paper, comparative concentration- and time-dependent effects of chromium(VI) and chromium(III) were demonstrated on increased production of reactive oxygen species (ROS) and lipid peroxidation, enhanced excretion of urinary lipid metabolites, DNA fragmentation and apoptotic cell death in both in vitro and in vivo models. Chromium(VI) demonstrated significantly higher toxicity as compared with chromium(III). To evaluate the role of p53 gene, the dose-dependent effects of chromium(VI) were assessed in female C57BL/6Ntac and p53-deficient C57BL/6TSG p53 mice on enhanced production of ROS, lipid peroxidation and DNA fragmentation in hepatic and brain tissues. Chromium(VI) induced more pronounced oxidative damage in multiple target organs in p53 deficient mice. Comparative studies of chromium(III) picolinate and niacin-bound chromium(III), two popular dietary supplements, reveal that chromium(III) picolinate produces significantly more oxidative stress and DNA damage. Studies have implicated the toxicity of chromium picolinate in renal impairment, skin blisters and pustules, anemia, hemolysis, tissue edema, liver dysfunction; neuronal cell injury, impaired cognitive, perceptual and motor activity; enhanced production of hydroxyl

  15. Nickel on the Swedish market. Follow-up after implementation of the Nickel Directive.

    PubMed

    Lidén, Carola; Norberg, Kristina

    2005-01-01

    The Nickel Directive aims at the prevention of sensitization and elicitation of nickel dermatitis. It limits nickel release from, and nickel content in, certain items. The Directive came into full force by July 2001. The aim of this study was to investigate the frequency on the market of items that release nickel and of nickel content in piercing posts, 2 years after coming into force of the Directive. Of special interest was to study changes compared to the situation in 1999, when a baseline study had been carried out. Nickel release from 786 items covered by the Nickel Directive was tested with the dimethylglyoxime (DMG) test, and nickel content in 18 piercing posts was analysed. Nickel release was shown from 8% of items intended for direct and prolonged contact with the skin, and 17% of the piercing posts contained too much nickel, a decrease compared to 1999. There has been significant adaptation to the requirements of the Nickel Directive. The DMG test is useful for screening for nickel release and for monitoring the market. Provided there is further adaptation to the requirements, the risk of sensitization and elicitation of nickel dermatitis will be significantly reduced.

  16. NAVAIR Hexavalent Chromium Minimization Status

    DTIC Science & Technology

    2010-11-01

    NAVAIR  Hexavalent  Chromium Minimization Status  SERDP/ESTCP Symposium 2010 Cr6+ Session Bill C Nickerson AIR 4.3.4 Report Documentation Page Form...COVERED 00-00-2010 to 00-00-2010 4. TITLE AND SUBTITLE NAVAIR Hexavalent Chromium Minimization Status 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c...ANSI Std Z39-18 Minimizing Hexavalent Chromium Use in DoD Operations Technical Session No. 2B C-39 NAVAIR NON-CHROMATE MATERIALS STATUS MR

  17. Deep eutectic solvent approach towards nickel/nickel nitride nanocomposites

    DOE PAGES

    Gage, Samuel H.; Ruddy, Daniel A.; Pylypenko, Svitlana; ...

    2016-12-15

    Nickel nitride is an attractive material for a broad range of applications including catalysis. However preparations and especially those targeting nanoscale particles remain a major challenge. Herein, we report a wet-chemical approach to produce nickel/nickel nitride nanocomposites using deep eutectic solvents. A choline chloride/urea deep eutectic solvent was used as a reaction medium to form gels containing nickel acetate tetrahydrate. Heat treatment of the gel in inert atmosphere forms nanoparticles embedded within a nitrogen-doped carbon matrix. Thermogravimetric analysis (TGA) and differential thermal analysis (DTA) were used to understand the decomposition profile of the precursors and to select pyrolysis temperatures locatedmore » in regions of thermal stability. X-ray diffraction (XRD) confirmed the presence of metallic nickel, whereas X-ray photoelectron spectroscopy (XPS) suggested the existence of a nickel nitride surface layer. According to transmission electron microscopy (TEM) analysis these mixed phase, possibly core-shell type nanoparticles, have very defined facets. Furthermore, these materials represent a unique opportunity to tune catalytic properties of nickel-based catalysts through control of their composition, surface structure, and morphology; in addition to employing potential benefits of a nitrogen-doped carbon support.« less

  18. SSCC TD: A Serial and Simultaneous Configural-Cue Compound Stimuli Representation for Temporal Difference Learning

    PubMed Central

    Mondragón, Esther; Gray, Jonathan; Alonso, Eduardo; Bonardi, Charlotte; Jennings, Dómhnall J.

    2014-01-01

    This paper presents a novel representational framework for the Temporal Difference (TD) model of learning, which allows the computation of configural stimuli – cumulative compounds of stimuli that generate perceptual emergents known as configural cues. This Simultaneous and Serial Configural-cue Compound Stimuli Temporal Difference model (SSCC TD) can model both simultaneous and serial stimulus compounds, as well as compounds including the experimental context. This modification significantly broadens the range of phenomena which the TD paradigm can explain, and allows it to predict phenomena which traditional TD solutions cannot, particularly effects that depend on compound stimuli functioning as a whole, such as pattern learning and serial structural discriminations, and context-related effects. PMID:25054799

  19. Inertial Navigation System for India's Reusable Launch Vehicle-Technology Demonstrator (RLV-TD HEX) Mission

    NASA Astrophysics Data System (ADS)

    Umadevi, P.; Navas, A.; Karuturi, Kesavabrahmaji; Shukkoor, A. Abdul; Kumar, J. Krishna; Sreekumar, Sreejith; Basim, A. Mohammed

    2017-12-01

    This work presents the configuration of Inertial Navigation System (INS) used in India's Reusable Launch Vehicle-Technology Demonstrator (RLV-TD) Program. In view of the specific features and requirements of the RLV-TD, specific improvements and modifications were required in the INS. A new system was designed, realised and qualified meeting the mission requirements of RLV-TD, at the same time taking advantage of the flight heritage attained in INS through various Launch vehicle Missions of the country. The new system has additional redundancy in acceleration channel, in-built inclinometer based bias update scheme for acceleration channels and sign conventions as employed in an aircraft. Data acquisition in micro cycle periodicity (10 ms) was incorporated which was required to provide rate and attitude information at higher sampling rate for ascent phase control. Provision was incorporated for acquisition of rate and acceleration data with high resolution for aerodynamic characterisation and parameter estimation. GPS aided navigation scheme was incorporated to meet the stringent accuracy requirements of the mission. Navigation system configuration for RLV-TD, specific features incorporated to meet the mission requirements, various tests carried out and performance during RLV-TD flight are highlighted.

  20. An investigation of the magnetic field of Transient Disturbances (TD) at the Earth's orbit, and a determination of solar sources of TD from their characteristics at R = 1 AU

    NASA Technical Reports Server (NTRS)

    Fainshtein, V. .G.; Kaigorodov, A. P.

    1995-01-01

    We have investigated and intercompared the typical features of the magnetic field of two types of solar wind transient disturbances with shock waves: the shock wave is accompanied by a magnetic cloud (MC), and the shock wave is followed by a region with bidirectional solar wind electron heat flux (BEHF), with no MC present. In this case, a separate study was made of the field features in two typical TD structures: in the region of impact-compressed solar wind between the shock wave and MC or BEHF, as well as in MC and BEHF. The study has provided new results on the influence of the ambient SW upon the TD magnetic field and the relationship between fields in various TD structures. A new test for the existence of interplanetary magnetic field draping around MC and BEHF is proposed and verified. It is concluded that the magnetic field configuration around MC is more adequately consistent with the concept of magnetic line draping than is the case around BEHF Two methods are proposed to infer the location of solar sources of TD from their characteristics at R = 1 AU.

  1. A new chromium carbide-based tribological coating for use to 900 C with particular reference to the Stirling engine

    NASA Technical Reports Server (NTRS)

    Sliney, Harold E.

    1986-01-01

    A new chromium carbide-based coating (PS 200) is described. This coating is shown to have good friction and wear properties over a wide temperature range. A nickel alloy-bonded chromium carbide coating was used as a baseline material for comparison with experimentally formulated coatings. Coatings were plasma sprayed onto metal disks, then diamond ground to a thickness of 0.025 cm. Friction and wear were determined using a pin on disk tribometer at temperatures from 25 to 900 C in hydrogen, helium, and air. Pin materials included several metallic alloys and silicon carbide. It was found that appropriate additions of metallic silver and of barium fluoride/calcium fluoride eutectic to the baseline carbide composition significantly reduced friction coefficients while preserving, and in some cases, even enhancing wear resistance. The results of this study demonstrate that PS 200 is a promising coating composition to consider for high temperature aerospace and advanced heat engine applications. The excellent results in hydrogen make this coating of particular interest for use in the Stirling engine.

  2. Factors Affecting Nickel-oxide Electrode Capacity in Nickel-hydrogen Cells

    NASA Technical Reports Server (NTRS)

    Ritterman, P. F.

    1984-01-01

    The nickel-oxide electrode common to the nickel hydrogen and nickel cadmium cell is by design the limiting or capacity determining electrode on both charge and discharge. The useable discharge capacity from this electrode, and since it is the limiting electrode, the useable discharge capacity of the cell as well, can and is optimized by rate of charge, charge temperature and additives to electrode and electrolyte. Recent tests with nickel hydrogen cells and tests performed almost 25 years ago with nickel cadmium cells indicate an improvement of capacity as a result of using increased electrolyte concentration.

  3. Nickel-based rechargeable batteries

    NASA Astrophysics Data System (ADS)

    Shukla, A. K.; Venugopalan, S.; Hariprakash, B.

    Nickel-iron (Ni-Fe), nickel-cadmium (Ni-Cd), nickel-hydrogen (Ni-H 2), nickel-metal hydride (Ni-MH) and nickel-zinc (Ni-Zn) batteries employ nickel oxide electrodes as the positive plates, and are hence, categorised as nickel-based batteries. This article highlights the operating principles and advances made in these battery systems during the recent years. In particular, significant improvements have been made in the Ni-MH batteries which are slowly capturing the market occupied by the ubiquitous Ni-Cd batteries.

  4. 40 CFR 421.323 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Chromium (total) 27.14 11.00 Copper 93.88 44.74 Nickel 40.34 27.14 Fluoride 2,567.00 1,459.00 (b) Slag... in the refinery Chromium (total) 1.689 0.685 Copper 5.844 2.785 Nickel 2.511 1.689 Fluoride 159.800... per million pounds) of uranium processed in the refinery Chromium (total) 2.357 0.955 Copper 8.152 3...

  5. 40 CFR 421.323 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Chromium (total) 27.14 11.00 Copper 93.88 44.74 Nickel 40.34 27.14 Fluoride 2,567.00 1,459.00 (b) Slag... in the refinery Chromium (total) 1.689 0.685 Copper 5.844 2.785 Nickel 2.511 1.689 Fluoride 159.800... per million pounds) of uranium processed in the refinery Chromium (total) 2.357 0.955 Copper 8.152 3...

  6. 40 CFR 420.102 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ....000626 O&G 0.000522 0.000209 Chromium 1 0.0000209 0.0000084 Lead 0.0000094 0.0000031 Nickel 1 0.0000188 0... limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling...) of product TSS 0.00626 0.00313 O&G 0.00261 0.00104 Chromium 1 0.000104 0.0000418 Lead 0.0000469 0...

  7. 40 CFR 420.102 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ....000626 O&G 0.000522 0.000209 Chromium 1 0.0000209 0.0000084 Lead 0.0000094 0.0000031 Nickel 1 0.0000188 0... limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling...) of product TSS 0.00626 0.00313 O&G 0.00261 0.00104 Chromium 1 0.000104 0.0000418 Lead 0.0000469 0...

  8. 40 CFR 420.102 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ....000626 O&G 0.000522 0.000209 Chromium 1 0.0000209 0.0000084 Lead 0.0000094 0.0000031 Nickel 1 0.0000188 0... limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling...) of product TSS 0.00626 0.00313 O&G 0.00261 0.00104 Chromium 1 0.000104 0.0000418 Lead 0.0000469 0...

  9. 40 CFR 420.102 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....000626 O&G 0.000522 0.000209 Chromium 1 0.0000209 0.0000084 Lead 0.0000094 0.0000031 Nickel 1 0.0000188 0... limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling...) of product TSS 0.00626 0.00313 O&G 0.00261 0.00104 Chromium 1 0.000104 0.0000418 Lead 0.0000469 0...

  10. 40 CFR 420.102 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ....000626 O&G 0.000522 0.000209 Chromium 1 0.0000209 0.0000084 Lead 0.0000094 0.0000031 Nickel 1 0.0000188 0... limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling...) of product TSS 0.00626 0.00313 O&G 0.00261 0.00104 Chromium 1 0.000104 0.0000418 Lead 0.0000469 0...

  11. Shedding light on the Early Pleistocene of TD6 (Gran Dolina, Atapuerca, Spain): The technological sequence and occupational inferences

    PubMed Central

    2018-01-01

    This paper aims to update the information available on the lithic assemblage from the entire sequence of TD6 now that the most recent excavations have been completed, and to explore possible changes in both occupational patterns and technological strategies evidenced in the unit. This is the first study to analyse the entire TD6 sequence, including subunits TD6.3 and TD6.1, which have never been studied, along with the better-known TD6.2 Homo antecessor-bearing subunit. We also present an analysis of several lithic refits found in TD6, as well as certain technical features that may help characterise the hominin occupations. The archaeo-palaeontological record from TD6 consists of 9,452 faunal remains, 443 coprolites, 1,046 lithic pieces, 170 hominin remains and 91 Celtis seeds. The characteristics of this record seem to indicate two main stages of occupation. In the oldest subunit, TD6.3, the lithic assemblage points to the light and limited hominin occupation of the cave, which does, however, grow over the course of the level. In contrast, the lithic assemblages from TD6.2 and TD6.1 are rich and varied, which may reflect Gran Dolina cave’s establishment as a landmark in the region. Despite the occupational differences between the lowermost subunit and the rest of the deposit, technologically the TD6 lithic assemblage is extremely homogeneous throughout. In addition, the composition and spatial distribution of the 12 groups of lithic refits found in unit TD6, as well as the in situ nature of the assemblage demonstrate the high degree of preservation at the site. This may help clarify the nature of the Early Pleistocene hominin occupations of TD6, and raise reasonable doubt about the latest interpretations that support the ex situ character of the assemblage as a whole. PMID:29370188

  12. Shedding light on the Early Pleistocene of TD6 (Gran Dolina, Atapuerca, Spain): The technological sequence and occupational inferences.

    PubMed

    Mosquera, Marina; Ollé, Andreu; Rodríguez-Álvarez, Xose Pedro; Carbonell, Eudald

    2018-01-01

    This paper aims to update the information available on the lithic assemblage from the entire sequence of TD6 now that the most recent excavations have been completed, and to explore possible changes in both occupational patterns and technological strategies evidenced in the unit. This is the first study to analyse the entire TD6 sequence, including subunits TD6.3 and TD6.1, which have never been studied, along with the better-known TD6.2 Homo antecessor-bearing subunit. We also present an analysis of several lithic refits found in TD6, as well as certain technical features that may help characterise the hominin occupations. The archaeo-palaeontological record from TD6 consists of 9,452 faunal remains, 443 coprolites, 1,046 lithic pieces, 170 hominin remains and 91 Celtis seeds. The characteristics of this record seem to indicate two main stages of occupation. In the oldest subunit, TD6.3, the lithic assemblage points to the light and limited hominin occupation of the cave, which does, however, grow over the course of the level. In contrast, the lithic assemblages from TD6.2 and TD6.1 are rich and varied, which may reflect Gran Dolina cave's establishment as a landmark in the region. Despite the occupational differences between the lowermost subunit and the rest of the deposit, technologically the TD6 lithic assemblage is extremely homogeneous throughout. In addition, the composition and spatial distribution of the 12 groups of lithic refits found in unit TD6, as well as the in situ nature of the assemblage demonstrate the high degree of preservation at the site. This may help clarify the nature of the Early Pleistocene hominin occupations of TD6, and raise reasonable doubt about the latest interpretations that support the ex situ character of the assemblage as a whole.

  13. 40 CFR 503.46 - Frequency of monitoring.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... arsenic, cadmium, chromium, lead, and nickel in sewage sludge fed to a sewage sludge incinerator shall be..., cadmium, chromium, lead, and nickel. (b) Total hydrocarbons, oxygen concentration, information to... monitored continuously. (c) Air pollution control device operating parameters.For sewage sludge incinerators...

  14. 40 CFR 503.46 - Frequency of monitoring.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... arsenic, cadmium, chromium, lead, and nickel in sewage sludge fed to a sewage sludge incinerator shall be..., cadmium, chromium, lead, and nickel. (b) Total hydrocarbons, oxygen concentration, information to... monitored continuously. (c) Air pollution control device operating parameters.For sewage sludge incinerators...

  15. Speciation of hexavalent chromium in welding fumes interference by air oxidation of chromium.

    PubMed

    Zatka, V J

    1985-06-01

    The determination of various chromium species in welding fume normally involves digestion in a hot alkaline solution. This work confirms that Cr(III) can be oxidized to Cr(VI) during this digestion. However, only dissolved forms of Cr(III), such as the hydroxochromate(III) ion, [Cr(OH)4], are susceptible to oxidation under these conditions. The air oxidation of Cr(III) can be prevented by hydrolytic destabilization of the hydroxochromate(III) complex by the presence of magnesium hydroxide precipitate. The procedure has been used successfully in the determination of insoluble chromium(VI) in welding fumes. Excellent reproducibility is documented for soluble and insoluble chromium(VI) fractions in the analysis of a bulk sample of welding fume.

  16. Pharmacokinetic Modeling of Trivalent and Hexavalent Chromium Based on Ingestion and Inhalation of Soluble Chromium Compounds.

    DTIC Science & Technology

    1991-12-01

    34 0-0-° AD-A256 238 - DTIC 7 ELECTE A S OCTI 6 1992 R CM S PHARMACOKINETIC MODELING OF T TRIVALENT AND HEXAVALENT CHROMIUM R BASED ON INGESTION AND...or inhalation of trivalent or hexavalent soluble chromium compounds. The research described herein began in June 1990 and was completed in December... trivalent and hexavalent chromium compounds, chromic chloride-hexahydrate and sodium dichromate, respectively (Table I). An inhalation control group was

  17. Stabilization of chromium: an alternative to make safe leathers.

    PubMed

    Gong, Ying; Liu, Xiaoling; Huang, Li; Chen, Wuyong

    2010-07-15

    In this study, the original causes for hexavalent chromium presence in the leather were first evaluated by ageing of chromium(III) solutions and chrome tanned hide powder (50 degrees C, UV lightening at 340 nm, 0-36 h). The results showed that the trivalent chromium at instable coordination state was easy to convert into hexavalent chromium in high pH environment, and the probability of the oxidation increased in this order: multi-coordinate chromium, mono-coordinate chromium, and free chromium. For this reason, the process for stabilizing chromium in the leather was designed with the specific material, which was mostly consisted of the reducers and the chelating agents. After treated with the developed process, these leathers were aged (50 degrees C, UV irradiance as 0.68 W/m(2) at 340 nm, 0-72 h) to estimate chromium(VI) presence. Hexavalent chromium was not found in these treated leathers even if the leathers were aged for 72 h. Moreover, the physical and mechanical properties for the leathers varied little after treating. In a word, an inherent safe and effective process was proved to avoid the formation of hexavalent chromium in the leather. 2010 Elsevier B.V. All rights reserved.

  18. Mineral of the month: chromium

    USGS Publications Warehouse

    Papp, John F.

    2005-01-01

    Chromium is one of the most indispensable industrial metals and it plays an essential but hidden role in daily life. Chromium is used in many consumer and building products, and it contributes to a clean, efficient and healthy environment.

  19. Nasal manifestations in chromium industry workers.

    PubMed

    Aiyer, R G; Kumar, Gaurav

    2003-04-01

    People working in mines, plating factories, cement industries are mainly exposed to chrome substances, IIexavalent chromium has been implicated for its toxic effect on the nasal mucosa. Hereby we present a rare study of 28 patients who attended out patient department of Otorhinolaryngology at SSG Hospital, Baroda from a nearby chromium industry. This study aims to present various nasal manifestations of toxic effects of prolonged chromium exposure.

  20. Production of basic chromium sulfate by using recovered chromium from ashes of thermally treated leather.

    PubMed

    Dettmer, Aline; Nunes, Keila Guerra Pacheco; Gutterres, Mariliz; Marcílio, Nilson Romeu

    2010-04-15

    Leather wastes tanned with chromium are generated during the production process of leather, hence the wastes from hand crafted goods and footwear industries are a serious environmental problem. The thermal treatment of leather wastes can be one of the treatment options because the wastes are rich in chromium and can be used as a raw material for sodium chromate production and further to obtain several chromium compounds. The objective of this study was to utilize the chromium from leather wastes via basic chromium sulfate production to be subsequently applied in a hide tanning. The obtained results have shown that this is the first successful attempt to achieve desired base properties of the product. The result was achieved when the following conditions were applied: a molar ratio between sodium sulfite and sodium dichromate equal to 6; reaction time equal to 5 min before addition of sulfuric acid; pH of sodium dichromate solution equal to 2. Summarizing, there is an opportunity to utilize the dangerous wastes and reused them in the production scheme by minimizing or annulling the environmental impact and to attend a sustainable process development concept. 2009 Elsevier B.V. All rights reserved.

  1. A comparative evaluation of bond strength of feldspathic porcelain to nickel-chromium alloy, when subjected to various surface treatments: An in vitro study

    PubMed Central

    Patel, Kavan A.; Mathur, Somil; Upadhyay, Snehal

    2015-01-01

    Purpose of the Study: The purpose was to evaluate the effect of various surface treatments and sandblasting with different particle size on the bond strength of feldspathic porcelain with predominantly base metal alloys, using a universal testing machine. Materials and Methods: Totally, 40 specimen of nickel-chromium alloy were prepared in an induction casting machine. The groups divided were as follows: Group I-sandblasted with 50 μ Al2O3, Group II-sandblasted with 110 μ Al2O3, Group III-sandblasted with 250 μ Al2O3 and Group IV-sandblasted with 250 μ Al2O3, followed by oxidation and again sandblasted with 250 μ Al2O3. The dimensions of each specimen were adjusted so as to maintain the thickness of ceramic at 1 mm. The specimen were loaded on the assembly of the universal testing machine, and a cross head speed of 0.5 mm/min was used to apply a compressive force at the junction of metal and feldspathic porcelain. The force application continued until adhesive fracture occurred, and the readings of the load applied to that particular specimen were recorded. Results: The means for shear bond strength for Group I, II, III and IV were found to be (226.92 ± 1.67), (233.16 ± 3.85), (337.81 ± 16.97) and (237.08 ± 4.33), respectively. Means of shear bond strength among the groups were compared using one-way analysis of variance test. Comparison between individual groups were made with Tukey's Honestly Significant Difference post-hoc test. Conclusion: Different particle size and surface treatment have an important role on the bond strength of ceramic-metal interface. Greater particle size demonstrated higher bond strength. PMID:26929487

  2. Excessive nickel release from mobile phones--a persistent cause of nickel allergy and dermatitis.

    PubMed

    Jensen, Peter; Johansen, Jeanne D; Zachariae, Claus; Menné, Torkil; Thyssen, Jacob P

    2011-12-01

    Despite the political intention to limit nickel allergy and dermatitis in Europeans, nickel allergy remains frequent. There are several explanations for the persistence of nickel allergy and dermatitis, including the increasing use of mobile phones. Before regulation of nickel release from mobile phones, we showed that eight (19.5%) of 41 mobile phones marketed in Denmark between 2003 and 2007 released nickel in concentrations that may result in nickel allergy and dermatitis. In 2009, the EU Nickel Directive was revised to include nickel-releasing mobile phones. To investigate the proportion of mobile phones sold in Denmark that release nickel after regulation. Metallic parts from 50 randomly selected mobile phones currently for sale in Denmark were tested for nickel release by use of the dimethylglyoxime (DMG)-nickel spot test. Nine (18%) phones showed at least one positive DMG test reaction and two phones had more than one DMG test-positive spot. Apparently, the proportion of mobile phones with significant nickel release remains unchanged, despite the 2009 revision of the EU Nickel Directive. We encourage manufacturers to measure nickel release from metallic components used in the assembly of mobile phones to ensure safe products. © 2011 John Wiley & Sons A/S.

  3. Development of a micro-fiber nickel electrode for nickel-hydrogen cell

    NASA Technical Reports Server (NTRS)

    Britton, Doris L.

    1995-01-01

    Development of a high specific energy nickel electrode is the main goal of the lightweight nickel electrode program at the NASA Lewis Research Center. The approach has been to improve the nickel electrode by continuing combined in-house and contract efforts to develop a more efficient and lighter weight electrode for the nickel-hydrogen cell. Small fiber diameter nickel plaques are used as conductive supports for the nickel hydroxide active material. These plaques are commercial products and have an advantage of increased surface area available for the deposition of active material. Initial tests include activation and capacity measurements at different discharge levels followed by half-cell cycle testing at 80 percent depth-of-discharge in a low-Earth-orbit regime. The electrodes that pass the initial tests are life cycle-tested in a boiler plate nickel-hydrogen cell before flightweight designs are built and tested.

  4. Auxiliary Electrodes for Chromium Vapor Sensors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fergus, Jeffrey; Shahzad, Moaiz; Britt, Tommy

    Measurement of chromia-containing vapors in solid oxide fuel cell systems is useful for monitoring and addressing cell degradation caused by oxidation of the chomia scale formed on alloys for interconnects and balance-of-plant components. One approach to measuring chromium is to use a solid electrolyte with an auxiliary electrode that relates the partial pressure of the chromium containing species to the mobile species in the electrolyte. One example is YCrO3 which can equilibrate with the chromium containing vapor and yttrium in yttria stabilized zirconia to establish an oxygen activity. Another is Na2CrO4 which can equilibrate with the chromium-containing vapor to establishmore » a sodium activity.« less

  5. 21 CFR 73.2327 - Chromium oxide greens.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... COLOR ADDITIVES EXEMPT FROM CERTIFICATION Cosmetics § 73.2327 Chromium oxide greens. (a) Identity and specifications. The color additive chromium oxide greens shall conform in identify and specifications to the requirements of § 73.1327 (a)(1) and (b). (b) Uses and restrictions. The color additive chromium oxide greens...

  6. 40 CFR 471.92 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Chromium 0.104 0.043 Cyanide 0.069 0.029 Nickel 0.455 0.301 Ammonia 31.6 13.9 Fluoride 14.1 6.26 (e... monthly average mg/off-kg (pounds per million off-pounds) of zirconium-hafnium heat treated Chromium 0.015... Chromium 0.150 0.061 Cyanide 0.099 0.041 Nickel 0.653 0.432 Ammonia 45.3 20 Fluoride 20.3 8.98 (i) Surface...

  7. 40 CFR 471.92 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Chromium 0.104 0.043 Cyanide 0.069 0.029 Nickel 0.455 0.301 Ammonia 31.6 13.9 Fluoride 14.1 6.26 (e... monthly average mg/off-kg (pounds per million off-pounds) of zirconium-hafnium heat treated Chromium 0.015... Chromium 0.150 0.061 Cyanide 0.099 0.041 Nickel 0.653 0.432 Ammonia 45.3 20 Fluoride 20.3 8.98 (i) Surface...

  8. 40 CFR 468.11 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... of copper or copper alloy hot rolled Chromium 0.045 0.018 Copper 0.195 0.103 Lead 0.015 0.013 Nickel... alloy cold rolled Chromium 0.166 0.068 Copper 0.720 0.379 Lead 0.056 0.049 Nickel 0.727 0.481 Zinc 0.553... drawn English units—pounds per 1,000,000 off-pounds of copper or copper alloy drawn Chromium 0.037 0.015...

  9. 40 CFR 468.13 - New source performance standards (NSPS).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... copper alloy hot rolled Chromium 0.038 0.015 Copper 0.131 0.062 Lead 0.010 0.0092 Nickel 0.056 0.038 Zinc... rolled English units—pounds per 1,000,000 off-pounds of copper or copper alloy cold rolled Chromium 0.140... copper or copper alloy drawn Chromium 0.031 0.012 Copper 0.108 0.051 Lead 0.0085 0.0076 Nickel 0.046 0...

  10. 40 CFR 468.14 - Pretreatment standards for existing sources (PSES).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... rolled English units—pounds per 1,000,000 off-pounds of copper or copper alloy hot rolled Chromium 0.045... alloy cold rolled Chromium 0.166 0.068 Copper 0.720 0.379 Lead 0.056 0.049 Nickel 0.727 0.481 Zinc 0.553... copper or copper alloy drawn Chromium 0.037 0.015 Copper 0.161 0.085 Lead 0.012 0.011 Nickel 0.163 0.107...

  11. 40 CFR 468.14 - Pretreatment standards for existing sources (PSES).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... rolled English units—pounds per 1,000,000 off-pounds of copper or copper alloy hot rolled Chromium 0.045... alloy cold rolled Chromium 0.166 0.068 Copper 0.720 0.379 Lead 0.056 0.049 Nickel 0.727 0.481 Zinc 0.553... copper or copper alloy drawn Chromium 0.037 0.015 Copper 0.161 0.085 Lead 0.012 0.011 Nickel 0.163 0.107...

  12. 40 CFR 468.11 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... of copper or copper alloy hot rolled Chromium 0.045 0.018 Copper 0.195 0.103 Lead 0.015 0.013 Nickel... alloy cold rolled Chromium 0.166 0.068 Copper 0.720 0.379 Lead 0.056 0.049 Nickel 0.727 0.481 Zinc 0.553... drawn English units—pounds per 1,000,000 off-pounds of copper or copper alloy drawn Chromium 0.037 0.015...

  13. 40 CFR 468.11 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... of copper or copper alloy hot rolled Chromium 0.045 0.018 Copper 0.195 0.103 Lead 0.015 0.013 Nickel... alloy cold rolled Chromium 0.166 0.068 Copper 0.720 0.379 Lead 0.056 0.049 Nickel 0.727 0.481 Zinc 0.553... drawn English units—pounds per 1,000,000 off-pounds of copper or copper alloy drawn Chromium 0.037 0.015...

  14. 40 CFR 468.13 - New source performance standards (NSPS).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... copper alloy hot rolled Chromium 0.038 0.015 Copper 0.131 0.062 Lead 0.010 0.0092 Nickel 0.056 0.038 Zinc... rolled English units—pounds per 1,000,000 off-pounds of copper or copper alloy cold rolled Chromium 0.140... copper or copper alloy drawn Chromium 0.031 0.012 Copper 0.108 0.051 Lead 0.0085 0.0076 Nickel 0.046 0...

  15. 40 CFR 468.13 - New source performance standards (NSPS).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... copper alloy hot rolled Chromium 0.038 0.015 Copper 0.131 0.062 Lead 0.010 0.0092 Nickel 0.056 0.038 Zinc... rolled English units—pounds per 1,000,000 off-pounds of copper or copper alloy cold rolled Chromium 0.140... copper or copper alloy drawn Chromium 0.031 0.012 Copper 0.108 0.051 Lead 0.0085 0.0076 Nickel 0.046 0...

  16. 40 CFR 468.14 - Pretreatment standards for existing sources (PSES).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... rolled English units—pounds per 1,000,000 off-pounds of copper or copper alloy hot rolled Chromium 0.045... alloy cold rolled Chromium 0.166 0.068 Copper 0.720 0.379 Lead 0.056 0.049 Nickel 0.727 0.481 Zinc 0.553... copper or copper alloy drawn Chromium 0.037 0.015 Copper 0.161 0.085 Lead 0.012 0.011 Nickel 0.163 0.107...

  17. 40 CFR 468.11 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... of copper or copper alloy hot rolled Chromium 0.045 0.018 Copper 0.195 0.103 Lead 0.015 0.013 Nickel... alloy cold rolled Chromium 0.166 0.068 Copper 0.720 0.379 Lead 0.056 0.049 Nickel 0.727 0.481 Zinc 0.553... drawn English units—pounds per 1,000,000 off-pounds of copper or copper alloy drawn Chromium 0.037 0.015...

  18. 40 CFR 421.305 - Pretreatment standards for existing sources.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... pounds) of TiCl4 produced Chromium (total) 0.346 0.140 Lead 0.262 0.122 Nickel 0.515 0.346 Titanium 0.496.../kg (pounds per million pounds) of TiCl4 produced Chromium (total) 0.385 0.156 Lead 0.291 0.135 Nickel... monthly average mg/kg (pounds per million pounds) of TiCl4 handled Chromium (total) 0.069 0.028 Lead 0.052...

  19. 40 CFR 421.305 - Pretreatment standards for existing sources.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... pounds) of TiCl4 produced Chromium (total) 0.346 0.140 Lead 0.262 0.122 Nickel 0.515 0.346 Titanium 0.496.../kg (pounds per million pounds) of TiCl4 produced Chromium (total) 0.385 0.156 Lead 0.291 0.135 Nickel... monthly average mg/kg (pounds per million pounds) of TiCl4 handled Chromium (total) 0.069 0.028 Lead 0.052...

  20. 40 CFR 421.305 - Pretreatment standards for existing sources.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... pounds) of TiCl4 produced Chromium (total) 0.346 0.140 Lead 0.262 0.122 Nickel 0.515 0.346 Titanium 0.496.../kg (pounds per million pounds) of TiCl4 produced Chromium (total) 0.385 0.156 Lead 0.291 0.135 Nickel... monthly average mg/kg (pounds per million pounds) of TiCl4 handled Chromium (total) 0.069 0.028 Lead 0.052...

  1. A new chromium carbide-based tribological coating for use to 900 deg C with particular reference to the Stirling engine

    NASA Technical Reports Server (NTRS)

    Sliney, H. E.

    1986-01-01

    A new chromium carbide-based coating (PS 200) is described. This coating is shown to have good friction and wear properties over a wide temperature range. A nickel alloy-bonded chromium carbide coating was used as a baseline material for comparison with experimental formulated coatings. Coatings were plasma sprayed onto metal disks, then diamond ground to a thickness of 0.025 cm. Friction and wear were determined using a pin on disk tribometer at temperatures from 25 to 900 C in hydrogen, helium, and air. Pin materials included several metallic alloys and silicon carbide. It was found that appropriate additions of metallic silver and of barium fluoride/calcium fluoride eutectic to the baseline carbide composition significantly reduced friction coefficients while preserving, and in some cases, even enhancing wear resistance. The results of this study demonstrate that PS 200 is a promising coating composition to consider for high temperature aerospace and advanced heat engine applications. The excellent results in hydrogen make this coating of particular interest for use in the Stirling engine.

  2. Effects of TD-5108 on Gastrointestinal Transit and Bowel Function in Health and Pharmacokinetics in Health and Constipation

    PubMed Central

    Manini, Mhd Louai; Camilleri, Michael; Goldberg, Michael; Sweetser, Seth; McKinzie, Sanna; Burton, Duane; Wong, Shekman; Kitt, Michael M.; Li, Yu-Ping; Zinsmeister, Alan R.

    2010-01-01

    Background TD-5108 is a potent, selective high intrinsic activity serotonin 5-HT4 receptor agonist. Aim To assess effects of TD-5108 on gastrointestinal transit and compare its pharmacokinetics (PK) in healthy volunteers (HV) and chronic constipation (CC) patients. Methods 60 HV were randomly assigned, double-blind to placebo, 5, 15, 30 or 50 mg TD-5108 (single and 6-day dosing). Primary endpoints were colonic transit (geometric center at 24 hours, GC24) and ascending colon emptying (ACE) T1/2 after first dose. Secondary endpoints included gastric emptying (GE) T1/2 and colonic filling at 6 h (CF6). Results Single dose TD-5108 significantly accelerated GC24, ACE T1/2, and CF6; 30 and 50°mg TD-5108 accelerated all 3 endpoints. With multiple doses, TD-5108 30 mg accelerated GC24, and overall accelerated GE T1/2 at 15–50 mg. PK studies showed dose proportionality in health, and no significant differences between health and chronic constipation with a 15 mg oral dose of TD-5108. Stimulation of bowel function after15 mg TD-5108 were similar in CC and controls. There were no serious adverse events; notable adverse were the predictable GI effects such as diarrhea or altered bowel movements. Conclusions TD-5108 significantly accelerated intestinal and colonic transit after single dosing and accelerated gastric emptying after multiple dosing. Further studies of its potential as a gastrointestinal and colonic prokinetic are warranted. PMID:19691492

  3. TD-LTE Wireless Private Network QoS Transmission Protection

    NASA Astrophysics Data System (ADS)

    Zhang, Jianming; Cheng, Chao; Wu, Zanhong

    With the commencement of construction of the smart grid, the demand power business for reliability and security continues to improve, the reliability transmission of power TD-LTE Wireless Private Network are more and more attention. For TD-LTE power private network, it can provide different QoS services according to the user's business type, to protect the reliable transmission of business. This article describes in detail the AF module of PCC in the EPC network, specifically introduces set up AF module station and QoS mechanisms in the EPS load, fully considers the business characteristics of the special power network, establishing a suitable architecture for mapping QoS parameters, ensuring the implementation of each QoS business. Through using radio bearer management, we can achieve the reliable transmission of each business on physical channel.

  4. Establishment of a reference value for chromium in the blood for biological monitoring among occupational chromium workers.

    PubMed

    Li, Ping; Li, Yang; Zhang, Ji; Yu, Shan-Fa; Wang, Zhi-Liang; Jia, Guang

    2016-10-01

    The concentration of chromium in the blood (CrB) has been confirmed as a biomarker for occupational chromium exposure, but its biological exposure indices (BEIs) are still unclear, so we collected data from the years 2006 and 2008 (Shandong Province, China) to analyze the relationship between the concentration of chromium in the air (CrA) of the workplaces and CrB to establish a reference value of CrB for biological monitoring of occupational workers. The levels of the indicators for nasal injury, kidney (β2 microglobulin (β2-MG)), and genetic damages (8-hydroxy-deoxyguanosine (8-OHdG) and micronucleus (MN)) were measured in all subjects of the year 2011 (Henan Province, China) to verify the protective effect in this reference value of CrB. Compared with the control groups, the concentrations of CrA and CrB in chromium exposed groups were significantly higher (P < 0.05). Positive correlations were found between CrA and CrB in chromium exposed groups (r 2006 = 0.60, r 2008 = 0.35) in the years 2006 and 2008. According to the occupational exposure limitation of CrA (50 μg/m(3), China), the reference value of CrB was recommended to 20 μg/L. The levels of nasal injury, β2-MG, 8-OhdG, and MN were not significantly different between the low chromium exposed group (CrB ≤ 20 μg/L) and the control group, while the levels of β2-MG, 8-OHdG, and MN were statistically different in the high chromium exposed group than that in the control group. This research proved that only in occupational workers, CrB could be used as a biomarker to show chromium exposure in the environment. The recommended reference value of CrB was 20 μg/L. © The Author(s) 2015.

  5. 21 CFR 73.1326 - Chromium hydroxide green.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... COLOR ADDITIVES EXEMPT FROM CERTIFICATION Drugs § 73.1326 Chromium hydroxide green. (a) Identity. (1) The color additive chromium hydroxide green is principally hydrated chromic sesquioxide (Cr2O3·XH2O). (2) Color additive mixtures for drug use made with chromium hydroxide green may contain only those...

  6. Chromium in urine, serum and red blood cells in the biological monitoring of workers exposed to different chromium valency states.

    PubMed

    Minoia, C; Cavalleri, A

    1988-06-01

    Using personal air sampling exposure to hexavalent and trivalent chromium was measured in 22 workers mainly exposed to Cr(VI) and in 15 workers mainly exposed to Cr(III) as basic chromium sulphate. Determination of Cr(VI) in the urine of all the subjects using a selective technique by ETA-AAS and liquid anion exchangers failed to show detectable amounts of the hexavalent form, the detection limit of the technique being 0.05 micrograms/L. A clear relationship between exposure and postshift urinary total chromium was found in subjects exposed to Cr(VI), while urinary levels in workers exposed to chromic sulphate high concentration proved lower. Determination of total chromium in serum and red blood cells showed a significant increase of chromium levels in erythrocytes of workers exposed to Cr(VI) while in subjects mainly exposed to Cr(III) an increase of the serum fraction was observed. The results demonstrate that Cr(III) is absorbed through the respiratory tract, but its kinetics and distribution in the body are not the same as for Cr(VI), and are not adequately monitored by short-term urinary determinations. Oxidation states of chromium largely influence uptake, mechanism of absorption, transport and organ distribution as well as toxicity of chromium-containing compounds. In particular, hexavalent derivatives are known to induce adverse effects, both acute and chronic, in occupationally exposed subjects, while there is little conclusive evidence for toxic effects caused by trivalent chromium compounds. Biological monitoring of exposure to chromium(VI) has usually been performed by determining total chromium levels in urine, whereas biological monitoring data in subjects occupationally exposed to Cr(III) are still scanty.(ABSTRACT TRUNCATED AT 250 WORDS)

  7. Chromium fate in constructed wetlands treating tannery wastewaters.

    PubMed

    Dotro, Gabriela; Palazolo, Paul; Larsen, Daniel

    2009-06-01

    Nine experimental wetlands were built to determine chromium partitioning inside systems treating tannery wastewaters. Results showed 5-day biochemical oxygen demand and chromium removals of 95 to 99% and 90 to 99%, respectively. The majority of chromium was found in association with media (96 to 98%), followed by effluents (2.9 to 3.9%), and the least was found in plant parts (0.1%). Chemical speciation modeling of solutions and scanning electron microscope analysis suggest two potential chromium removal mechanisms--sorption/coprecipitation with iron hydroxides or oxyhydroxides and biomass sorption. The release of the majority of chromium in the iron- and organic-bound phases during sequential extractions supports the proposed dominant removal mechanisms. The use of a mixture of peat and gravel resulted in lower removal efficiencies and stronger partitioning in organic phases during sequential extractions. Chromium was efficiently removed by wetlands, retained through chemical and biological processes. Future research will focus on further exploring removal mechanisms and proposing management strategies for the chromium-containing wetland media.

  8. Persistent pollution of Warta river catchment with chromium: case study from central Poland

    NASA Astrophysics Data System (ADS)

    Hermanski, S.; Lukaczynski, I.; Nikiel, G.; Mizera, J.; Dulinski, M.; Kania, J.; Rozanski, K.; Szklarczyk, T.; Wachniew, P.; Witczak, S.; Zurek, A.

    2012-04-01

    Upper reaches of the Warta river, the third largest river in Poland, are located in a densely populated and industrialized area, with presence of heavy industry going back to the second half of the XIX century. Industrial activities include iron smelters in towns of Częstochowa and Zawiercie, large chemical plants (Rudniki and Aniolow) producing predominantly chromium compounds, paper and textile industry, as well as large number of small enterprises specialized in metal coatings (nickel and chromium). Until the 1960s all the industrial and municipal effluents in the region were discharged into the Warta river and its tributaries. Solid wastes were dumped on the surface, mostly without appropriate cover and isolation. This resulted in progressive contamination of surface waters and groundwater with heavy metals, mostly chromium. The upper reaches of the Warta river are located on top of upper Jurassic Major Groundwater Basin (MGWB 326 which is one of four most important groundwater reservoirs in Poland. Almost all potable water demands in the area (ca. 340,000 inhabitants, 800 factories and enterprises) are covered by MGWB 326 (50 deep wells with the average extraction rate of 57,000 m3/d). As the MGWB 326 is mostly phreatic, it has been recognized since long time that persistent pollution of the upper catchment of the Warta river with heavy metals may pose serious thread to quality of this important groundwater resource. In this presentation we summarize the work carried out to date, focused on characterization of the extent and understanding of the mechanisms of pollution of surface water, sediments and groundwater in MGWB 326 with chromium. Historical monitoring data of the levels of chromium in the Warta river and its tributaries are presented, supplemented by the results of measurements of Cr loads in Warta over-bank deposits and Cr levels in groundwater production wells in the area. Three conceptual models of spreading of chromium in the catchment of Warta

  9. Influence of Crucible Materials on High-temperature Properties of Vacuum-melted Nickel-chromium-cobalt Alloy

    NASA Technical Reports Server (NTRS)

    Decker, R F; Rowe, John P; Freeman, J W

    1957-01-01

    A study of the effect of induction-vacuum-melting procedure on the high-temperature properties of a titanium-and-aluminum-hardened nickel-base alloy revealed that a major variable was the type of ceramic used as a crucible. Reactions between the melt and magnesia or zirconia crucibles apparently increased high-temperature properties by introducing small amounts of boron or zirconium into the melts. Heats melted in alumina crucibles had relatively low rupture life and ductility at 1,600 F and cracked during hot-working as a result of deriving no boron or zirconium from the crucible.

  10. Purity of food cooked in stainless steel utensils.

    PubMed

    Flint, G N; Packirisamy, S

    1997-01-01

    An extensive programme of cooking operations, using household recipes, has shown that, apart from aberrant values associated with new pans on first use, the contribution made by 19% Cr/9% Ni stainless steel cooking utensils to chromium and nickel in the diet is negligible. New pans, if first used with acid fruits, showed a greater pick-up of chromium and nickel, ranging from approximately 1/20 to 1/3 and 1/20 to 1/2 of the normal daily intake of chromium and nickel respectively. This situation did not recur in subsequent usage, even after the pan had been cleaned by abrasion. A higher rate of chromium and nickel release in new pans on first use was observed on products from four manufactures and appears to be related to surface finish, since treatment of the surface of a new pan was partly, and in the case of electropolishing, wholly effective in eliminating their initial high release.

  11. The relationship between alloying elements and biologically produced ennoblement in natural waters.

    PubMed

    Eashwar, M; Lakshman Kumar, A; Hariharasuthan, R; Sreedhar, G

    2015-01-01

    A range of stainless steels, nickel-chromium and nickel-chromium-molybdenum alloys were exposed to coastal seawater from Mandapam (Indian Ocean) and freshwater from a perennial pond. Biofilms from both test waters produced an ennoblement of the open circuit potential (OCP) on all alloys as expected, which was slower but substantially larger in freshwater. In both waters an interesting relationship was perceived between the plateau OCP (Emax) and the mass percentage of the major alloying elements. In particular, iron exhibited strong positive correlations with Emax (r(2) ≥ 0.77; p < 0.0005), while the sum of chromium, nickel and molybdenum presented significant negative correlations (r(2) ≤ -0.81; p = 0.0002). Consistent with the regression analyses, Euclidean distance clustering yielded patterns where Inconel-600 and the nickel-chromium-molybdenum alloys had the smallest similarities of OCP with other alloys. The results emphatically reinforce a key role for surface passive films in the ennoblement phenomenon in natural waters.

  12. The chromium accumulation and its physiological effects in juvenile rockfish, Sebastes schlegelii, exposed to different levels of dietary chromium (Cr(6+)) concentrations.

    PubMed

    Kim, Jun-Hwan; Kang, Ju-Chan

    2016-01-01

    Juvenile rockfish (mean length 13.7±1.7 cm, and mean weight 55.6±4.8 g) were exposed for 4 weeks with the different levels of dietary chromium (Cr(6+)) at 0, 30, 60, 120 and 240 mg/kg. The profile of chromium in the tissues of rockfish is dependent on the exposure periods and chromium concentration. After 4 weeks, the order of chromium accumulation in tissues was liver>kidney>spleen>intestine>gill>muscle. The dietary chromium exposure decreased the growth rate and hepatosomatic index of rockfish. The major hematological findings were significant decrease in the red blood cell (RBC) count, hematocrit (Ht) value, and hemoglobin (Hb) concentration exposed to ≥120 mg/kg chromium concentrations. The dietary chromium exposure (≥120 mg/kg) led to notable increase in glucose, cholesterol, glutamic oxalate transaminase (GOT), and glutamic pyruvate transaminase (GPT) in plasma, whereas there was no considerable change in calcium, magnesium, total protein, and alkaline phosphatase (ALP). The results indicated that the dietary chromium exposure to rockfish can induce significant chromium accumulation in the specific tissues, inhibition of growth, and hematological alterations. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Materials Research for Superconducting Machinery-IV

    DTIC Science & Technology

    1975-09-01

    Mechanical properties of fabricated metal joints, including welding ( GTAW , EB, GMAW), brazing, and soldering from 4-300 K. Propertle» Include tensile...nickel alloys; a precipita- tion-hardening copper alloy; invar; nickel- chromium -iron alloys; stainless steels; and the composite materials boron...temperature; the first 4 K fatigue llT^t tou£me88 "udies on a nitrogen-strengthened chromium -nickel-manganese steel, which show this material has higher

  14. Acute and chronic systemic chromium toxicity.

    PubMed

    Gad, S C

    1989-10-01

    Although chromium and compounds containing it have been recognized as having potential severe adverse effects on health for more than 160 years, understanding of the systemic toxicology and true hazard of these compounds is still not complete. A review of the current state of knowledge is attempted in this paper, with appropriate attention given to the complications of multiple valence states and solubility. Selected chromium compounds, particularly hexavalent ones, are carcinogens, corrosives, delayed contact sensitizers, and have the kidney as their primary target organ. But chromium is also an essential element for humans. The body clearly possesses some effective detoxification mechanisms for some degree of exposure to hexavalent chrome compounds. The significant features of acute and chronic chromium toxicity are presented in view of these considerations.

  15. Modulation in magnetic exchange interaction, core shell structure and Hopkinson's peak with chromium substitution into Ni0.75Co0.25Fe2O4 nano particles

    NASA Astrophysics Data System (ADS)

    Uday Bhasker, S.; Choudary, G. S. V. R. K.; Reddy, M. V. Ramana

    2018-05-01

    The ever growing applications and ever evolving challenges of magnetic nano particles has been motivating the researchers from various disciplines towards this area of magnetic nano particles. Cation substitutional effect on the magnetic structure of the nanoparticles forms a crucial aspect in their applications. Here the environmentally benign auto combustion method was employed to synthesize chromium substituted nickel cobalt ferrite (Ni0.75Co0.25Fe2-xCrxO4; x = 0, 0.10, 0.15) nano particles, from aqueous metal nitrate solutions. Chromium substitution has shown its effect on the structural, magnetic and electrical properties of Ni0.75Co0.25Fe2O4. Structural and phase analysis of the prepared samples show increased phase purity of ferrite sample with increasing Cr substitution. The TEM (Transmission Electron Microscope) image confirms the nano size of the particles, EDS (Energy dispersive X-ray Spectroscopy) has supported the stoichiometry of the prepared samples and FTIR (Fourier-transform infrared spectroscopic) analysis confirms the spinel structure and also suggests cation redistributions with chromium substitution. VSM (Vibrational Sample Magnetometer) is used to study the magnetic properties through magnetic hysteresis (M-H) loop and magnetic Hopkinson effect. All samples show hysteresis and show reduction in magnetic properties with increase in chromium content. The thermo magnetic study shows Hopkinson peak(s) in the magnetization vs. temperature (M-T) graph and also shows variation in the nature of Hopkinson peak with chromium substitution. Possible reasons for the changes in the nature of the peak are discussed.

  16. 21 CFR 73.1326 - Chromium hydroxide green.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 1 2011-04-01 2011-04-01 false Chromium hydroxide green. 73.1326 Section 73.1326... COLOR ADDITIVES EXEMPT FROM CERTIFICATION Drugs § 73.1326 Chromium hydroxide green. (a) Identity. (1) The color additive chromium hydroxide green is principally hydrated chromic sesquioxide (Cr2O3·XH2O...

  17. Chromium

    USDA-ARS?s Scientific Manuscript database

    The effects of chromium (Cr) on glucose and insulin metabolism are well documented. Normal dietary intake of Cr appears to be suboptimal because several studies have reported beneficial effects of Cr in people with elevated blood glucose or type 2 diabetes eating conventional diets. Stresses that ...

  18. Diffusional creep and creep degradation in the dispersion-strengthened alloy TD-NiCr

    NASA Technical Reports Server (NTRS)

    Whittenberger, J. D.

    1972-01-01

    Dispersoid-free regions were observed in TD-NiCr (Ni-20Cr-2ThO2) after slow strain rate testing in air from 1145 to 1590 K. Formation of the dispersoid-free regions appears to be the result of diffusional creep. The net effect of this creep is the degradation of TD-NiCr to a duplex microstructure. Degradation is further enhanced by the formation of voids and integranular oxidation in the thoria-free regions. These regions apparently provided sites for void formation and oxide growth since the strength and oxidation resistance of Ni-20Cr is much less than Ni-20Cr-2ThO2. This localized oxidation does not appear to reduce the static load bearing capacity of TD-NiCr since long stress rupture lives were observed even with heavily oxidized microstructures. But this oxidation does significantly reduce the ductility and impact resistance of the material. Dispersoid-free bands and voids were also observed for two other dispersion strengthened alloys, TD-NiCrAl and IN-853. Thus, it appears that diffusional creep is charactertistic of dispersion-strengthened alloys and can play a major role in the creep degradation of these materials.

  19. Enhanced efficacy of TD53, a novel algicidal agent, against the harmful algae via the liposomal delivery system.

    PubMed

    Han, Hyo-Kyung; Kim, Yeon-Mi; Lim, Soo-Jeong; Hong, Soon-Seok; Jung, Seul-Gi; Cho, Hoon; Lee, Wonjae; Jin, Eonseon

    2011-02-28

    The present study aimed to design the liposomal delivery system for TD53, a novel algicial drug in order to improve the delivery properties of TD53 and evaluate its algicidal effects as well as selectivity against harmful and non-harmful algae. Liposomes of TD53 were prepared with 1,2-dimyristoyl-sn-glycero-3-phosphocholine (DMPC) by a lyophilization, resulting in relatively small size vesicles (234±38nm) and narrow size distribution (PI=0.130±0.027). The drug leakage from the liposome was negligible in the F/2 media (<2% during 96h incubation). Subsequently algicidal activity of liposomal TD53 against harmful and nonharmful algae was evaluated at various concentrations. The IC(50) values of TD53 in liposome against harmful algae such as Chattonella marina, Heterosigma akashiwo and Cocholodinium polykrikoides were 2.675, 2.029, and 0.480μM, respectively, and were reduced by approximately 50% compared to those obtained from non-liposomal TD53. In contrast, the algicidal effect of liposomal TD53 was insignificant against non-harmful algae including Navicula pelliculosa, Nannochloropsis oculata and Phaeodactylum EPV. Those results suggested that liposomal delivery systems might be effective to enhance the efficacy of TD53 while maintaining the selectivity to harmful algal species. Copyright © 2010 Elsevier B.V. All rights reserved.

  20. Method of improving fatigue life of cast nickel based superalloys and composition

    DOEpatents

    Denzine, Allen F.; Kolakowski, Thomas A.; Wallace, John F.

    1978-03-14

    The invention consists of a method of producing a fine equiaxed grain structure (ASTM 2-4) in cast nickel-base superalloys which increases low cycle fatigue lives without detrimental effects on stress rupture properties to temperatures as high as 1800.degree. F. These superalloys are variations of the basic nickel-chromium matrix, hardened by gamma prime [Ni.sub.3 (Al, Ti)] but with optional additions of cobalt, tungsten, molybdenum, vanadium, columbium, tantalum, boron, zirconium, carbon and hafnium. The invention grain refines these alloys to ASTM 2 to 4 increasing low cycle fatigue life by a factor of 2 to 5 (i.e. life of 700 hours would be increased to 1400 to 3500 hours for a given stress) as a result of the addition of 0.01% to 0.2% of a member of the group consisting of boron, zirconium and mixtures thereof to aid heterogeneous nucleation. The alloy is vacuum melted and heated to 250.degree.-400.degree. F. above the melting temperature, cooled to partial solidification, thus resulting in said heterogeneous nucleation and fine grains, then reheated and cast at about 50.degree.-100.degree. F. of superheat. Additions of 0.1% boron and 0.1% zirconium (optional) are the preferred nucleating agents.

  1. Optical properties of alkali halide crystals from all-electron hybrid TD-DFT calculations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Webster, R., E-mail: ross.webster07@imperial.ac.uk; Harrison, N. M.; Bernasconi, L.

    2015-06-07

    We present a study of the electronic and optical properties of a series of alkali halide crystals AX, with A = Li, Na, K, Rb and X = F, Cl, Br based on a recent implementation of hybrid-exchange time-dependent density functional theory (TD-DFT) (TD-B3LYP) in the all-electron Gaussian basis set code CRYSTAL. We examine, in particular, the impact of basis set size and quality on the prediction of the optical gap and exciton binding energy. The formation of bound excitons by photoexcitation is observed in all the studied systems and this is shown to be correlated to specific features ofmore » the Hartree-Fock exchange component of the TD-DFT response kernel. All computed optical gaps and exciton binding energies are however markedly below estimated experimental and, where available, 2-particle Green’s function (GW-Bethe-Salpeter equation, GW-BSE) values. We attribute this reduced exciton binding to the incorrect asymptotics of the B3LYP exchange correlation ground state functional and of the TD-B3LYP response kernel, which lead to a large underestimation of the Coulomb interaction between the excited electron and hole wavefunctions. Considering LiF as an example, we correlate the asymptotic behaviour of the TD-B3LYP kernel to the fraction of Fock exchange admixed in the ground state functional c{sub HF} and show that there exists one value of c{sub HF} (∼0.32) that reproduces at least semi-quantitatively the optical gap of this material.« less

  2. Production of Chromium Oxide from Turkish Chromite Concentrate Using Ethanol

    NASA Astrophysics Data System (ADS)

    Aktas, S.; Eyuboglu, C.; Morcali, M. H.; Özbey, S.; Sucuoglu, Y.

    2015-05-01

    In this study, the possibility of chromium extraction from Turkish chromite concentrate and the production of chromium oxide were investigated. For the conversion of chromium(III) into chromium(VI), NaOH was employed, as well as air with a rate of 20 L/min. The effects of the base amount, fusing temperature, and fusing time on the chromium conversion percentage were investigated in detail. The conversion kinetics of chromium(III) to chromium(VI) was also undertaken. Following the steps of dissolving the sodium chromate in water and filtering, aluminum hydroxide was precipitated by adjusting the pH level of the solution. The chromium(VI) solution was subsequently converted to Cr(III) by the combination of sulfuric acid and ethanol. Interestingly, it was observed that ethanol precipitated chromium as chromium(VI) at mildly acidic pH levels, although this effect is more pronounced for K2Cr2O7 than Na2Cr2O7. On the other hand, in the strongly acidic regime, ethanol acted as a reducing agent role in that chromium(VI) was converted into Cr(III) whereas ethanol itself was oxidized to carbon dioxide and water. Subsequently, chromium hydroxide was obtained by the help of sodium hydroxide and converted to chromium oxide by heating at 800 °C, as indicated in thermo gravimetric analysis (TGA).

  3. The effects of platinum on nickel electrodes in the nickel hydrogen cell

    NASA Technical Reports Server (NTRS)

    Zimmerman, Albert H.

    1991-01-01

    Interactions of platinum and platinum compounds with the nickel electrode that are possible in the nickel hydrogen cell, where both the nickel electrode and a platinum catalyst hydrogen electrode are in intimate contact with the alkaline electrolyte, are examined. Additionally, a mechanism of nickel cobalt oxyhydroxide formation in NiH2 cells is presented.

  4. Bending Properties of Nickel Electrodes for Nickel-Hydrogen Batteries

    NASA Technical Reports Server (NTRS)

    Lerch, Brad A.; Wilson, Richard M.; Keller, Dennis; Corner, Ralph

    1995-01-01

    Recent changes in manufacturing have resulted in nickel-hydrogen batteries that fail prematurely by electrical shorting, This failure is believed to be a result of a blistering problem in the nickel electrodes. In this study the bending properties of nickel electrodes are investigated in an attempt to correlate the bending properties of the electrode with its propensity to blister. Nickel electrodes from three different batches of material were tested in both the as-received and impregnated forms. The effects of specimen curvature and position within the electrode on the bending strength were studied, and within-electrode and batch-to-batch variations were addressed. Two color-imaging techniques were employed to differentiate between the phases within the electrodes. These techniques aided in distinguishing the relative amounts of nickel hyroxide surface loading on each electrode, thereby relating surface loading to bend strength. Bend strength was found to increase with the amount of surface loading.

  5. Studies on the essentiality of chromium in ruminants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Samsell, L.J.; Spears, J.W.

    1986-03-01

    Although chromium has been established as an essential trace element for certain animal species, no requirement has been shown for ruminants. Sixteen female lambs (35 kg) were used in an attempt to determine if chromium is essential in the ruminant. Animals were individually housed in all plastic pens and fed twice daily either a low chromium (100 ppb) torula yeast based diet or the basal diet supplemented with 10 ppm chromium as CrCl/sub 3/. Blood samples obtained prior to the morning feeding and 2 and 6 hr post-feeding on days 28 and 56 indicated no significant treatment differences in plasmamore » glucose or serum free fatty acids. By day 56, serum cholesterol tended to be lower in chromium supplemented lambs (60.9 vs 71.7 mg/dl). Lambs in the chromium supplemented treatment also tended to gain more efficiently through 56 days (.130 vs .118 gain/fed). On day 84, lambs were bled after a 48 hr fast, refed, then bled again at 2 and 6 hr post-feeding. Plasma glucose and serum free fatty acids were not affected by chromium at the end of the 48 hr fast or when lambs were refed following fasting. At 84 days both total serum cholesterol and HDL-cholesterol were lower in lambs receiving supplemental chromium. These results suggest that chromium may have a biological role in the ruminant.« less

  6. Processes affecting the remediation of chromium-contaminated sites.

    PubMed

    Palmer, C D; Wittbrodt, P R

    1991-05-01

    The remediation of chromium-contaminated sites requires knowledge of the processes that control the migration and transformation of chromium. Advection, dispersion, and diffusion are physical processes affecting the rate at which contaminants can migrate in the subsurface. Heterogeneity is an important factor that affects the contribution of each of these mechanisms to the migration of chromium-laden waters. Redox reactions, chemical speciation, adsorption/desorption phenomena, and precipitation/dissolution reactions control the transformation and mobility of chromium. The reduction of CrVI to CrIII can occur in the presence of ferrous iron in solution or in mineral phases, reduced sulfur compounds, or soil organic matter. At neutral to alkaline pH, the CrIII precipitates as amorphous hydroxides or forms complexes with organic matter. CrIII is oxidized by manganese dioxide, a common mineral found in many soils. Solid-phase precipitates of hexavalent chromium such as barium chromate can serve either as sources or sinks for CrVI. Adsorption of CrVI in soils increases with decreasing chromium concentration, making it more difficult to remove the chromium as the concentration decreases during pump-and-treat remediation. Knowledge of these chemical and physical processes is important in developing and selecting effective, cost-efficient remediation designs for chromium-contaminated sites.

  7. Hexavalent and trivalent chromium in leather: What should be done?

    PubMed

    Moretto, Angelo

    2015-11-01

    Trivalent chromium compounds are used for leather tanning, and chromium may be released during use of leather goods. In certain instances, small amounts of hexavalent chromium can be formed and released. Both trivalent and hexavalent chromium can elicit allergic skin reaction in chromium sensitised subjects, the latter being significantly more potent. Induction of sensitisation only occurs after exposure to hexavalent chromium. A minority of subjects are sensitised to chromium, and in a fraction of these subjects allergic skin reaction have been described after wearing leather shoes or, less frequently, other leather goods. The evidence that in all these cases the reaction is related to hexavalent chromium is not always strong. The content of hexavalent chromium in leather is regulated in European Union, but rate of release rather than content is relevant for allergic skin reaction. The role of trivalent chromium appear much less relevant if at all. Modern tanning procedure do not pose significant risk due to either hexavalent or trivalent chromium. Dismissing bad quality and worn-off leather goods is relevant in reducing or eliminating the skin reaction. It should also be pointed out that shoe components or substances other than chromium in leather may cause allergic/irritative skin reactions. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Dielectric and magnetic studies of Cr+3 doped nickel ferrite by combustion method

    NASA Astrophysics Data System (ADS)

    Parveez, Asiya; Shekhawat, M. S.; Sindhu, S.; Srikanth, C.; Nayeem, Firdous; Mohd. Shariff, S.; Sinha, R. R.; Chaudhuri, Arka; Khader, S. Abdul

    2018-05-01

    Cr+3 doped nickel ferrite nanoparticles having the basic composition NiCrxFe2-xO4 (x=0, 0.1, 0.15, 0.2, 1) were prepared using auto combustion method. Structural, dielectric, a.c conductivity and magnetic properties of these samples, which are sintered at 800°C were studied. The structures of the synthesized samples were probed by X-ray diffraction (XRD) studies. The peaks observed in the XRD spectrum indicated single phase spinel cubic structure for the synthesized samples. Surface morphology of the samples has been investigated using Field Emission Scanning Electron Microscope (FESEM). The dielectric constant (ɛ') and dielectric loss factor (ɛ″) of nanocrystalline nickel ferrites were investigated as a function of frequency and Cr+3 concentration at room temperature over the frequency range 100 Hz to 1 MHz using Hioki make LCR Hi-Tester 3250. The dependence of ɛ' and ɛ″ with the frequency of the alternating applied electric field is in accordance with the Maxwell-Wagner type interfacial polarization, which is in agreement with the Koop's theory. The electrical conductivity (σac) deduced from the measured dielectric data has been thoroughly analyzed and found that the conduction mechanism in NiCrxFe2-xO4 nanoferrites are in conformity with the electron hopping model. The magnetic properties of Cr+3 doped nano-nickel ferrite were analyzed using a Vibrating Sample Magnetometer (VSM). It is observed that the values of saturation magnetization decreases along with the increase in chromium content.

  9. Development of a Micro-Fiber Nickel Electrode for Nickel-Hydrogen Cell

    NASA Technical Reports Server (NTRS)

    Britton, Doris L.

    1996-01-01

    The development of a high specific energy battery is one of the objectives of the lightweight nickel-hydrogen (NiH2) program at the NASA Lewis Research Center. The approach has been to improve the nickel electrode by continuing combined in-house and contract efforts to develop a more efficient and lighter weight electrode for the nickel-hydrogen fuel cell. Small fiber diameter nickel plaques are used as conductive supports for the nickel hydroxide active material. These plaques are commercial products and have an advantage of increased surface area available for the deposition of active materials. Initial tests include activation and capacity measurements at different discharge levels followed by half-cell cycle testing at 80 percent depth-of-discharge in a low Earth orbit regime. The electrodes that pass the initial tests are life cycle tested in a boiler plate nickel-hydrogen cell before flightweight designs are built and tested.

  10. Chromium supplementation improved post-stroke brain infarction and hyperglycemia.

    PubMed

    Chen, Wen-Ying; Mao, Frank Chiahung; Liu, Chia-Hsin; Kuan, Yu-Hsiang; Lai, Nai-Wei; Wu, Chih-Cheng; Chen, Chun-Jung

    2016-04-01

    Hyperglycemia is common after acute stroke and is associated with a worse outcome of stroke. Thus, a better understanding of stress hyperglycemia is helpful to the prevention and therapeutic treatment of stroke. Chromium is an essential nutrient required for optimal insulin activity and normal carbohydrate and lipid metabolism. Beyond its nutritional effects, dietary supplement of chromium causes beneficial outcomes against several diseases, in particular diabetes-associated complications. In this study, we investigated whether post-stroke hyperglycemia involved chromium dynamic mobilization in a rat model of permanent focal cerebral ischemia and whether dietary supplement of chromium improved post-stroke injury and alterations. Stroke rats developed brain infarction, hyperglycemia, hyperinsulinemia, glucose intolerance, and insulin resistance. Post-stroke hyperglycemia was accompanied by elevated secretion of counter-regulatory hormones including glucagon, corticosterone, and norepinephrine, decreased insulin signaling in skeletal muscles, and increased hepatic gluconeogenesis. Correlation studies revealed that counter-regulatory hormone secretion showed a positive correlation with chromium loss and blood glucose increased together with chromium loss. Daily chromium supplementation increased tissue chromium levels, attenuated brain infarction, improved hyperglycemia, and decreased plasma levels of glucagon and corticosterone in stroke rats. Our findings suggest that stroke rats show disturbance of tissue chromium homeostasis with a net loss through urinary excretion and chromium mobilization and loss might be an alternative mechanism responsible for post-stroke hyperglycemia.

  11. Electrochemical impregnation and cycle life of lightweight nickel electrodes for nickel-hydrogen cells

    NASA Technical Reports Server (NTRS)

    Britton, Doris L.

    1990-01-01

    Development of a high specific energy nickel electrode is the main goal of the lightweight nickel electrode program at NASA-Lewis. The approach was to improve the nickel electrode by continuing combined in-house and contract efforts to develop a more efficient and lighter weight electrode for the nickel-hydrogen cell. Lightweight plaques are used as conductive supports for the nickel hydroxide active material. These plaques are commercial products that are fabricated into nickel electrodes by electrochemically impregnating them with active material. The electrodes are life cycle tested in a low Earth orbit regime at 40 and 80 percent depths-of-discharge.

  12. Electrochemical impregnation and cycle life of lightweight nickel electrodes for nickel-hydrogen cells

    NASA Technical Reports Server (NTRS)

    Britton, Doris L.

    1990-01-01

    Development of a high specific energy nickel electrode is the main goal of the lightweight nickel electrode program at NASA-Lewis. The approach was to improve the nickel electrode by continuing combined in-house and contract efforts to develop a more efficient and lighter weight electrode for the nickel-hydrogen cell. Lightweight plaques are used as conductive supports for the nickel hydroxide active material. These plaques are commercial products that are fabricated into nickel electrodes by electrochemically impregnating them with active material. The electrodes are life cycle tested in a low earth orbit regime at 40 and 80 percent depths-of-discharge.

  13. Resistance of nickel-chromium-aluminum alloys to cyclic oxidation at 1100 C and 1200 C

    NASA Technical Reports Server (NTRS)

    Barrett, C. A.; Lowell, C. E.

    1976-01-01

    Nickel-rich alloys in the Ni-Cr-Al system were evaluated for cyclic oxidation resistance in still air at 1,100 and 1,200 C. A first approximation oxidation attack parameter Ka was derived from specific weight change data involving both a scaling growth constant and a spalling constant. An estimating equation was derived with Ka as a function of the Cr and Al content by multiple linear regression and translated into countour ternary diagrams showing regions of minimum attack. An additional factor inferred from the regression analysis was that alloys melted in zirconia crucibles had significantly greater oxidation resistance than comparable alloys melted otherwise.

  14. Flight Weight Design Nickel-Hydrogen Cells Using Lightweight Nickel Fiber Electrodes

    NASA Technical Reports Server (NTRS)

    Britton, Doris L.; Willis, Bob; Pickett, David F.

    2003-01-01

    The goal of this program is to develop a lightweight nickel electrode for advanced aerospace nickel-hydrogen cells and batteries with improved specific energy and specific volume. The lightweight nickel electrode will improve the specific energy of a nickel-hydrogen cell by >50%. These near-term advanced batteries will reduce power system mass and volume, while decreasing the cost, thus increasing mission capabilities and enabling small spacecraft missions. This development also offers a cost savings over the traditional sinter development methods for fabrication. The technology has been transferred to Eagle-Picher, a major aerospace battery manufacturer, who has scaled up the process developed at NASA GRC and fabricated electrodes for incorporation into flight-weight nickel-hydrogen cells.

  15. Evaluation of chromium in red blood cells as an indicator of exposure to hexavalent chromium: An in vitro study.

    PubMed

    Devoy, Jérôme; Géhin, Antoine; Müller, Samuel; Melczer, Mathieu; Remy, Aurélie; Antoine, Guillaume; Sponne, Isabelle

    2016-07-25

    Chromium(VI) compounds are classified as carcinogenic to humans. Whereas chromium measurements in urine and whole blood (i.e., including plasma) are indicative of recent exposure, chromium in red blood cells (RBC) is attributable specifically to Cr(VI) exposure. Before recommending Cr in RBC as a biological indicator of Cr(VI) exposure, in-vitro studies must be undertaken to assess its reliability. The present study examines the relationship between the chromium added to a blood sample and that subsequently found in the RBC. After incubation of total blood with chromium, RBC were isolated, counted and their viability assessed. Direct analysis of chromium in RBC was conducted using Atomic Absorption Spectrometry. Hexavalent, but not trivalent Cr, was seen to accumulate in the RBC and we found a strong correlation between the Cr(VI) concentration added to a blood sample and the amount of Cr in RBC. This relationship appears to be independent of the chemical properties of the human blood samples (e.g., different blood donors or different reducing capacities). Even though in-vivo studies are still needed to integrate our understanding of Cr(VI) toxicokinetics, our findings reinforce the idea that a single determination of the chromium concentration in RBC would enable biomonitoring of critical cases of Cr(VI) exposure. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  16. Spectroscopic and Thermal Behavior of Chromium Soaps

    NASA Astrophysics Data System (ADS)

    Mehrotra, K. N.; Jain, Mamta

    1996-02-01

    The physicochemical characteristics of chromium soaps (myristate and stearate) were investigated in the solid state (thermal, X-ray, and IR measurements) and in solutions (spectrophotometric measurements). The thermal measurements showed that the decomposition of chromium soaps is a two-step process. The soap decomposed into chromium oxycarboxylate, ketone, and carbon dioxide in the first step and the intermediate oxycarboxylate underwent further decomposition to chromium trioxide in the second step. The results showed that the second step is kinetically of zero order and the values of energy of activation for the first and second steps lie in the ranges 6-7 and 17-18 kcal mol-1, respectively. The X-ray diffraction results showed that these soaps possess double-layer structure with molecular axes slightly inclined to the basal plane. The infrared results revealed that the fatty acids exist with dimeric structure through hydrogen bonding between two molecules of fatty acids whereas the metal-to-oxygen bonds in chromium soaps are not purely ionic but possess considerable covalent character. The results of spectrophotometric measurements also confirmed the somewhat covalent nature of chromium soaps in solutions in dichloromethane.

  17. Phosphate solubilization and chromium (VI) remediation potential of Klebsiella sp. strain CPSB4 isolated from the chromium contaminated agricultural soil.

    PubMed

    Gupta, Pratishtha; Kumar, Vipin; Usmani, Zeba; Rani, Rupa; Chandra, Avantika

    2018-02-01

    In this study, an effort was made to identify an efficient phosphate solubilizing bacterial strain from chromium contaminated agricultural soils. Based on the formation of a solubilized halo around the colonies on Pikovskaya's agar amended with chromium (VI), 10 strains were initially screened out. Out of 10, strain CPSB4, which showed significantly high solubilization zone at different chromium concentrations, was selected for further study. The strain CPSB4 showed significant plant growth promotion traits with chromium (VI) stress under in-vitro conditions in broth. The plant growth promotion activities of the strain decreased regularly, but were not completely lost with the increase in concentration of chromium up to 200 mg L -1 . On subjected to FT-IR analysis, the presence of the functional group, indicating the organic acid aiding in phosphate solubilization was identified. At an optimal temperature of 30  ° C and pH 7.0, the strain showed around 93% chromium (VI) reduction under in-vitro conditions in broth study. In soil condition, the maximum chromium (VI) reduction obtained was 95% under in-vitro conditions. The strain CPSB4 was identified as Klebsiella sp. on the basis of morphological, biochemical and 16S rRNA gene sequencing. This study shows that the diverse role of the bacterial strain CPSB4 would be useful in the chromium contaminated soil as a good bioremediation and plant growth promoting agent as well. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Luminescence of five-coordinated nickel(ii) complexes with substituted-8-hydroxyquinolines and macrocyclic ligands.

    PubMed

    Santana, M Dolores; García-Bueno, Rocío; García, Gabriel; Pérez, José; García, Luis; Monge, Miguel; Laguna, Antonio

    2010-02-21

    A series of heteroleptic quinolinolate pentacoordinated nickel(ii) complexes, [Ni(mcN(3))(R(1),R(2),R(3)-8-hq)](PF(6)), were synthesized and characterized by spectroscopic methods. Single-crystal X-ray diffraction studies for [(Me(3)-mcN(3))Ni(N,O-2-CN-8-hq)][PF(6)] (6a), [(Me(4)-mcN(3))Ni(N,O-8-hq)][PF(6)] (2b) and [(Me(4)-mcN(3))Ni(N,O-5,7-I(2)-8-hq)][PF(6)] (5b) indicate that these complexes consist of a square-pyramidal ligand arrangement containing one chelating quinolinolate and one macrocyclic ligand (mcN(3)). Variation of the substituents on quinolinolate ligands imposes obvious electronic or structural effects on the nickel atom. These chromophores absorb moderately in the visible region and emit in the yellowish-green spectral region from a quinolinolate-centered intraligand charge-transfer excited state. The emission maxima are in the range 520-548 nm, with quantum yields between 0.11 and 1.63%, in deoxygenated organic solvents at room temperature. TD-DFT calculations allow exploration of the photophysical properties of complex [(Me(4)-mcN(3))Ni(N,O-8-hq)][PF(6)] and reveal the influence of the quinolinolate ligand on the HOMO/LUMO energies and oscillator strengths.

  19. Design and qualification of the SEU/TD Radiation Monitor chip

    NASA Technical Reports Server (NTRS)

    Buehler, Martin G.; Blaes, Brent R.; Soli, George A.; Zamani, Nasser; Hicks, Kenneth A.

    1992-01-01

    This report describes the design, fabrication, and testing of the Single-Event Upset/Total Dose (SEU/TD) Radiation Monitor chip. The Radiation Monitor is scheduled to fly on the Mid-Course Space Experiment Satellite (MSX). The Radiation Monitor chip consists of a custom-designed 4-bit SRAM for heavy ion detection and three MOSFET's for monitoring total dose. In addition the Radiation Monitor chip was tested along with three diagnostic chips: the processor monitor and the reliability and fault chips. These chips revealed the quality of the CMOS fabrication process. The SEU/TD Radiation Monitor chip had an initial functional yield of 94.6 percent. Forty-three (43) SEU SRAM's and 14 Total Dose MOSFET's passed the hermeticity and final electrical tests and were delivered to LL.

  20. 40 CFR 468.15 - Pretreatment standards for new sources (PSNS).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...—pounds per 1,000,000 off-pounds of copper or copper alloy hot rolled Chromium 0.038 0.015 Copper 0.131 0... Chromium 0.140 0.056 Copper 0.485 0.231 Lead 0.037 0.034 Nickel 0.208 0.140 Zinc 0.386 0.159 TTO 0.128 0... copper alloy drawn Chromium 0.031 0.012 Copper 0.108 0.051 Lead 0.0085 0.0076 Nickel 0.046 0.031 Zinc 0...

  1. 40 CFR 468.13 - New source performance standards (NSPS).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... rolled Chromium 0.038 0.015 Copper 0.131 0.062 Lead 0.010 0.0092 Nickel 0.056 0.038 Zinc 0.105 0.043 Oil... per 1,000,000 off-pounds of copper or copper alloy cold rolled Chromium 0.140 0.056 Copper 0.485 0.231... drawn Chromium 0.031 0.012 Copper 0.108 0.051 Lead 0.0085 0.0076 Nickel 0.046 0.031 Zinc 0.086 0.035 Oil...

  2. 40 CFR 468.15 - Pretreatment standards for new sources (PSNS).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...—pounds per 1,000,000 off-pounds of copper or copper alloy hot rolled Chromium 0.038 0.015 Copper 0.131 0... Chromium 0.140 0.056 Copper 0.485 0.231 Lead 0.037 0.034 Nickel 0.208 0.140 Zinc 0.386 0.159 TTO 0.128 0... copper alloy drawn Chromium 0.031 0.012 Copper 0.108 0.051 Lead 0.0085 0.0076 Nickel 0.046 0.031 Zinc 0...

  3. 40 CFR 468.15 - Pretreatment standards for new sources (PSNS).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...—pounds per 1,000,000 off-pounds of copper or copper alloy hot rolled Chromium 0.038 0.015 Copper 0.131 0... Chromium 0.140 0.056 Copper 0.485 0.231 Lead 0.037 0.034 Nickel 0.208 0.140 Zinc 0.386 0.159 TTO 0.128 0... copper alloy drawn Chromium 0.031 0.012 Copper 0.108 0.051 Lead 0.0085 0.0076 Nickel 0.046 0.031 Zinc 0...

  4. Lipid peroxidation in workers exposed to hexavalent chromium.

    PubMed

    Huang, Y L; Chen, C Y; Sheu, J Y; Chuang, I C; Pan, J H; Lin, T H

    1999-02-26

    The aim of this study was to investigate whether exposure to hexavalent chromium induces lipid peroxidation in human. This study involved 25 chrome-plating factory workers and a reference group of 28 control subjects. The whole-blood and urinary chromium concentrations were determined by graphite furnace atomic absorption spectrophotometry. Malondialdehyde (MDA), the product of lipid peroxidation, was determined by high-performance liquid chromatography, and the activities of protective enzymes were measured by ultraviolet-visible spectrophotometry. In the chrome-plating workers, the mean concentrations of chromium in blood and urine were 5.98 microg/L and 5.25 microg/g creatinine, respectively; the mean concentrations of MDA in blood and urine were 1.7 micromol/L and 2.24 micromol/g creatinine. The concentrations of both chromium and MDA in blood and urine were significantly higher in the chromium-exposed workers. The activities of superoxide dismutase (SOD), glutathione peroxidase (GPX), and catalase (CAT) were not markedly different between control and exposed workers. Data suggest that MDA may be used as a biomarker for occupational chromium exposure. Antioxidant enzymic activities are not a suitable marker for chromium exposure.

  5. Development of forming and joining technology for TD-NiCr sheet

    NASA Technical Reports Server (NTRS)

    Torgerson, R. T.

    1973-01-01

    Forming joining techniques and properties data were developed for thin-gage TD-NiCr sheet in the recrystallized and unrecrystallized conditions. Theoretical and actual forming limit data are presented for several gages of each type of material for five forming processes: brake forming, corrugation forming, joggling, dimpling and beading. Recrystallized sheet can be best formed at room temperature, but unrecrystallized sheet requires forming at elevated temperature. Formability is satisfactory with most processes for the longitudinal orientation but poor for the transverse orientation. Dimpling techniques require further development for both material conditions. Data on joining techniques and joint properties are presented for four joining processes: resistance seam welding (solid-state), resistance spot welding (solid-state), resistance spot welding (fusion) and brazing. Resistance seam welded (solid-state) joints with 5t overlap were stronger than parent material for both material conditions when tested in tensile-shear and stress-rupture. Brazing studies resulted in development of NASA 18 braze alloy (Ni-16Cr-15Mo-8Al-4Si) with several properties superior to baseline TD-6 braze alloy, including lower brazing temperture, reduced reaction with Td-Ni-Cr, and higher stress-rupture properties.

  6. PROCESS OF COATING WITH NICKEL BY THE DECOMPOSITION OF NICKEL CARBONYL

    DOEpatents

    Hoover, T.B.

    1959-04-01

    An improved process is presented for the deposition of nickel coatings by the thermal decomposition of nickel carbonyl vapor. The improvement consists in incorporating a small amount of hydrogen sulfide gas in the nickel carbonyl plating gas. It is postulated that the hydrogen sulfide functions as a catalyst. i

  7. Chromium Exposure and Hygienic Behaviors in Printing Workers in Southern Thailand

    PubMed Central

    Decharat, Somsiri

    2015-01-01

    Objectives. The main objective of this study was to assess the chromium exposure levels in printing workers. The study evaluated the airborne, serum, and urinary chromium levels and determines any correlation between level of chromium in specimen and airborne chromium levels. Material and Methods. A cross-sectional study was conducted with 75 exposed and 75 matched nonexposed subjects. Air breathing zone was measured by furnace atomic absorption spectrophotometer. Serum and urine samples were collected to determine chromium levels by graphite furnaces atomic absorption spectrometer chromium analyzer. Results and Discussion. The printing workers' urinary chromium levels (6.86 ± 1.93 μg/g creatinine) and serum chromium levels (1.24 ± 1.13 μg/L) were significantly higher than the control group (p < 0.001 and p < 0.001). Work position, duration of work, personal protective equipment (PPE), and personal hygiene were significantly associated with urinary chromium level and serum chromium levels (p < 0.001 and p < 0.001). This study found a correlation between airborne chromium levels and urinary chromium levels (r = 0.247, p = 0.032). A multiple regression model was constructed. Significant predictors of urinary and serum chromium levels were shown in this study. Conclusion. Improvements in working conditions, occupational health training, and PPE use are recommended to reduce chromium exposure. PMID:26448746

  8. Coagulant from Leucaena leucocephala for Chromium Removal

    NASA Astrophysics Data System (ADS)

    Razak, N. H. Abd; Khairuddin, N.; Ismail, K. N.; Musa, M.

    2018-05-01

    This research investigated the effectiveness of leucaena leucocephala as a natural coagulant for chromium removal. Leucaena leucocephala is a permanent non-climbing shrub tree which is wild and abundant in Malaysia and commonly known as petai belalang. Coagulation experiment using jar test were performed where the effect of coagulant dosage and pH were examined. The parameters investigated were suspended solid (SS), chemical oxygen demand (COD), biological oxygen demand (BOD), turbidity and chromium content. The optimum of leucaena leucocephala coagulant dosage for removal of suspended solid, turbidity, COD, BOD and Chromium is at range 400-600 mg/L which yielded 45, 31.4, 38.5, 27.5 and 4.05% removal respectively. While the optimum pH is at pH 2-4 (acidic) which give 33.3, 26.8, 33.75, 31.4 and 14.06% removal of suspended solid, COD, BOD, turbidity and chromium content respectively. It is concluded that the leucaena leucocephala showed tremendous potential for chromium removal.

  9. Utilization of alum sludge as chromium removal

    NASA Astrophysics Data System (ADS)

    Zahari, Nazirul Mubin; Sidek, Lariyah Mohd; Zulkifli, Muhammad Azmeer Asyraf; Hua, Chua Kok; Jalil, Nurulhidayah Abdul

    2017-09-01

    The amount of alum sludge produced at water treatment plant has become a problem where it is highly costly in order to dispose them. Various research was conducted to find the most suitable and economic alternative to recycle and reused of alum sludge. In this study, alum sludge was retrieved from Waterworks where it was dewatered, dried, grounded and sieved to obtain smallest particle sizes of alum sludge. The synthetic water was prepared at the laboratory in as it was used to imitate the properties of real water contaminated with chromium. This study was conducted to determine the percentage reduction of chromium concentration in synthetic water by using alum sludge as absorbent. The percentage reduction of chromium was observed under the effect of initial concentration of chromium and the height of alum sludge. The result indicates that chromium concentration reduction was the highest at the lowest initial concentration and at the highest height of alum sludge and vice versa.

  10. A double-blind, randomized pilot trial of chromium picolinate for binge eating disorder: results of the Binge Eating and Chromium (BEACh) study.

    PubMed

    Brownley, Kimberly A; Von Holle, Ann; Hamer, Robert M; La Via, Maria; Bulik, Cynthia M

    2013-07-01

    Chromium treatment has been shown to improve mood, appetite, and glucose regulation in various psychiatric and medical patient populations. The authors propose that chromium may be useful in the treatment of binge eating disorder (BED). Twenty-four overweight adults with BED were enrolled in a 6-month double-blind placebo-controlled trial and randomly assigned to receive either 1000mcg chromium/day ("high dose"; n=8) or 600mcg chromium/day ("moderate dose"; n=9) as chromium picolinate or placebo (n=7). Mixed linear regression models were used to estimate mean change in binge frequency and related psychopathology, weight, symptoms of depression, and fasting glucose. Fasting glucose was significantly reduced in both chromium groups compared to the placebo group; similarly, numerically, but not significantly, greater reductions in binge frequency, weight, and symptoms of depression were observed in those treated with chromium versus placebo, although statistical power was limited in this pilot trial. For fasting glucose, the findings suggest a dose response with larger effects in the high dose compared to moderate dose group. These initial findings support further larger trials to determine chromium's efficacy in maintaining normal glucose regulation, reducing binge eating and related psychopathology, promoting modest weight loss, and reducing symptoms of depression in individuals with BED. Studies designed to link the clinical effects of chromium with changes in underlying insulin, serotonin, and dopamine pathways may be especially informative. If efficacious, chromium supplementation may provide a useful, low-cost alternative to or augmentation strategy for selective serotonin reuptake inhibitors, which have partial efficacy in BED. ClinicalTrials.gov NCT00904306. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. Ductile-brittle transition of thoriated chromium.

    NASA Technical Reports Server (NTRS)

    Wilcox, B. A.; Veigel, N. D.; Clauer, A. H.

    1972-01-01

    Unalloyed chromium and chromium containing approximately 3 wt % ThO2 were prepared from powder produced by a chemical vapor deposition process. When rolled to sheet and tested in tension, it was found that the thoriated material had a lower ductile-to-brittle transition temperature (DBTT) than unalloyed chromium. This ductilizing was evident both in the as-rolled condition and after the materials had been annealed for 1 hour at 1200 C. The improved ductility in thoriated chromium may be associated with several possible mechanisms: (1) particles may disperse slip, such that critical stress or strain concentrations for crack nucleation are more difficult to achieve; (2) particles may act as dislocation sources, thus providing mobile dislocations in this normally source-poor material, in a manner similar to prestraining; and (3) particles in grain boundaries may help to transmit slip across the boundaries, thus relieving stress concentrations and inhibiting crack nucleation.

  12. Hexavalent Chromium Reduction in the Aerospace Industry

    DTIC Science & Technology

    2010-12-01

    1 Hexavalent Chromium Reduction in the Aerospace Industry Unpublished work © 2010 Aerospace Industries Association of America, Inc. Lisa Goldberg...COVERED 00-00-2010 to 00-00-2010 4. TITLE AND SUBTITLE Hexavalent Chromium Reduction in the Aerospace Industry 5a. CONTRACT NUMBER 5b. GRANT...ABSTRACT AIA and its members have a long history in minimizing the use of hexavalent chromium in the manufacture of its products. Included in that history

  13. Recent Advances in the Synthesis and Stabilization of Nickel and Nickel Oxide Nanoparticles: A Green Adeptness

    PubMed Central

    Rani, Aneela

    2016-01-01

    Green protocols for the synthesis of nanoparticles have been attracting a lot of attention because they are eco-friendly, rapid, and cost-effective. Nickel and nickel oxide nanoparticles have been synthesized by green routes and characterized for impact of green chemistry on the properties and biological effects of nanoparticles in the last five years. Green synthesis, properties, and applications of nickel and nickel oxide nanoparticles have been reported in the literature. This review summarizes the synthesis of nickel and nickel oxide nanoparticles using different biological systems. This review also provides comparative overview of influence of chemical synthesis and green synthesis on structural properties of nickel and nickel oxide nanoparticles and their biological behavior. It concludes that green methods for synthesis of nickel and nickel oxide nanoparticles are better than chemical synthetic methods. PMID:27413375

  14. [Toxicological and analytical lists: chromium and its compounds].

    PubMed

    Minoia, C; Apostoli, P; Battaglia, A; Catenacci, G; Cottica, D; Franco, G; Pozzoli, L; Vanola, C; Candura, F; Capodaglio, E

    1987-03-01

    The main aspects of occupational exposure to chromium and chromium compounds are surveyed. Special attention is paid to the toxic action of this metal at the different target organs. The nutritional aspect of CrIII is examined preliminarily, and data detailing the metal contents in water and food are provided. As far the different working processes that entail occupational exposure to chromium are concerned, hygienic and environmental problems are discussed while identifying the average environment exposure to the different chemical forms of chromium (CrIII, CrIV, soluble and not soluble), as a function of the worker's tasks, and the relevant human response (total human Cr). Different hygienic and environmental standards in force in various countries and applicable to chromium compounds are compared. Additional information is given on the main aspects of chromium metabolism (absorption, distribution, excretion), and on the prevailing toxic actions, with specific reference to cancerogenesis. As far as biologic monitoring of the exposed people is concerned, the significance of Cr-U as dose-exposure indicator is discussed, also in the light of a critical review of the reference values. The report describes a series of analytical methods for the identification of chromium in aqueous and biologic matrices. The problems connected with health monitoring and fitness for work are eventually covered.

  15. Nickel exposure and plasma levels of biomarkers for assessing oxidative stress in nickel electroplating workers.

    PubMed

    Tsao, Yu-Chung; Gu, Po-Wen; Liu, Su-Hsun; Tzeng, I-Shiang; Chen, Jau-Yuan; Luo, Jiin-Chyuan John

    2017-07-01

    The mechanism of nickel-induced pathogenesis remains elusive. To examine effects of nickel exposure on plasma oxidative and anti-oxidative biomarkers. Biomarker data were collected from 154 workers with various levels of nickel exposure and from 73 controls. Correlations between nickel exposure and oxidative and anti-oxidative biomarkers were determined using linear regression models. Workers with a exposure to high nickel levels had significantly lower levels of anti-oxidants (glutathione and catalase) than those with a lower exposure to nickel; however, only glutathione showed an independent association after multivariable adjustment. Exposure to high levels of nickel may reduce serum anti-oxidative capacity.

  16. High temperature insulation barrier composite

    NASA Technical Reports Server (NTRS)

    Onstott, Joseph W. (Inventor)

    1989-01-01

    A composite material suitable for providing insulation for the nozzle structure of the Space Shuttle and other similar surfaces is disclosed. The composite layer is comprised of an outer skin layer of nickel chromium and an interleaved inner region comprising a top layer of nickel chromium foil which acts as a primary convective shield. There are at least two layers of alumina batting adjacent to the layers of silicon carbide fabric. An additional layer of nickel chromium foil is used as a secondary convective shield. The composite is particularly advantageous for use as nozzle insulation because of its ability to withstand high reentry temperatures, its flexibility, oxidation resistance, low conductivity, and light weight.

  17. Ferrate treatment for removing chromium from high-level radioactive tank waste.

    PubMed

    Sylvester, P; Rutherford, L A; Gonzalez-Martin, A; Kim, J; Rapko, B M; Lumetta, G J

    2001-01-01

    A method has been developed for removing chromium from alkaline high-level radioactive tank waste. Removing chromium from these wastes is critical in reducing the volume of waste requiring expensive immobilization and deep geologic disposition. The method developed is based on the oxidation of insoluble chromium(III) compounds to soluble chromate using ferrate. This method could be generally applicable to removing chromium from chromium-contaminated solids, when coupled with a subsequent reduction of the separated chromate back to chromium(III). The tests conducted with a simulated Hanford tank sludge indicate that the chromium removal with ferrate is more efficient at 5 M NaOH than at 3 M NaOH. Chromium removal increases with increasing Fe(VI)/Cr(II) molar ratio, but the chromium removal tends to level out for Fe(VI)/ Cr(III) greaterthan 10. Increasingtemperature leadsto better chromium removal, but higher temperatures also led to more rapid ferrate decomposition. Tests with radioactive Hanford tank waste generally confirmed the simulant results. In all cases examined, ferrate enhanced the chromium removal, with a typical removal of around 60-70% of the total chromium present in the washed sludge solids. The ferrate leachate solutions did not contain significant concentrations of transuranic elements, so these solutions could be disposed as low-activity waste.

  18. A physiologically based model of chromium kinetics in the rat.

    PubMed

    O'Flaherty, E J

    1996-05-01

    A physiologically based model of chromium kinetics in rats has been developed. The general structure of the model is similar to that of a model of lead kinetics in rats. Like lead chromium exchanges between plasma and the bone surfaces in contact with plasma, and also like lead, although with much lower efficiency, it can become incorporated into actively mineralizing bone. Both processes are included in the model. Parallel absorption and disposition schemes for chromium(VI) and chromium(III) are linked in the model by reduction processes occurring throughout the body, including the lung and gastrointestinal tract. Examination of a number of data sets from studies in which chromium salts were administered to rats intravenously, orally, or by intratracheal instillation established that intravenous administration, on the one hand, and oral or pulmonary administration, on the other hand, result in different disposition patterns. The model was calibrated based on published oral and intratracheal kinetic studies in rats given soluble chromium(III) and chromium(VI) salts. In the most complete of these studies, chromium concentrations were monitored in individual tissues for 42 days following intratracheal administration of a soluble chromium(VI) salt. Inclusion in the model of a urinary excretion delay was necessary in order to fit excretion data from two other intratracheal studies. Model predictions of blood chromium concentrations are compared with the results of a published kinetic study in which rats were administered a soluble chromium(VI) salt by inhalation.

  19. Chemical Speciation of Chromium in Drilling Muds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taguchi, Takeyoshi; Yoshii, Mitsuru; Shinoda, Kohzo

    2007-02-02

    Drilling muds are made of bentonite and other clays, and/or polymers, mixed with water to the desired viscosity. Without the drilling muds, corporations could not drill for oil and gas and we would have hardly any of the fuels and lubricants considered essential for modern industrial civilization. There are hundreds of drilling muds used and some kinds of drilling muds contain chromium. The chemical states of chromium in muds have been studied carefully due to concerns about the environmental influence. However it is difficult to determine the chemical state of chromium in drilling muds directly by conventional analytical methods. Wemore » have studied the chemical form of chromium in drilling muds by using a laboratory XAFS system and a synchrotron facility.« less

  20. Efficiency of silicon solar cells containing chromium

    DOEpatents

    Frosch, Robert A. Administrator of the National Aeronautics and Space; Salama, Amal M.

    1982-01-01

    Efficiency of silicon solar cells containing about 10.sup.15 atoms/cm.sup.3 of chromium is improved about 26% by thermal annealing of the silicon wafer at a temperature of 200.degree. C. to form chromium precipitates having a diameter of less than 1 Angstrom. Further improvement in efficiency is achieved by scribing laser lines onto the back surface of the wafer at a spacing of at least 0.5 mm and at a depth of less than 13 micrometers to preferentially precipitate chromium near the back surface and away from the junction region of the device. This provides an economical way to improve the deleterious effects of chromium, one of the impurities present in metallurgical grade silicon material.

  1. Nickel-free stainless steel avoids neointima formation following coronary stent implantation

    PubMed Central

    Fujiu, Katsuhito; Manabe, Ichiro; Sasaki, Makoto; Inoue, Motoki; Iwata, Hiroshi; Hasumi, Eriko; Komuro, Issei; Katada, Yasuyuki; Taguchi, Tetsushi; Nagai, Ryozo

    2012-01-01

    SUS316L stainless steel and cobalt–chromium and platinum–chromium alloys are widely used platforms for coronary stents. These alloys also contain nickel (Ni), which reportedly induces allergic reactions in some subjects and is known to have various cellular effects. The effects of Ni on neointima formation after stent implantation remain unknown, however. We developed coronary stents made of Ni-free high-nitrogen austenitic stainless steel prepared using a N2-gas pressurized electroslag remelting (P-ESR) process. Neointima formation and inflammatory responses following stent implantation in porcine coronary arteries were then compared between the Ni-free and SUS316L stainless steel stents. We found significantly less neointima formation and inflammation in arteries implanted with Ni-free stents, as compared to SUS316L stents. Notably, Ni2+ was eluted into the medium from SUS316L but not from Ni-free stainless steel. Mechanistically, Ni2+ increased levels of hypoxia inducible factor protein-1α (HIF-1α) and its target genes in cultured smooth muscle cells. HIF-1α and their target gene levels were also increased in the vascular wall at SUS316L stent sites but not at Ni-free stent sites. The Ni-free stainless steel coronary stent reduces neointima formation, in part by avoiding activation of inflammatory processes via the Ni-HIF pathway. The Ni-free-stainless steel stent is a promising new coronary stent platform. PMID:27877545

  2. Nickel-free stainless steel avoids neointima formation following coronary stent implantation.

    PubMed

    Fujiu, Katsuhito; Manabe, Ichiro; Sasaki, Makoto; Inoue, Motoki; Iwata, Hiroshi; Hasumi, Eriko; Komuro, Issei; Katada, Yasuyuki; Taguchi, Tetsushi; Nagai, Ryozo

    2012-12-01

    SUS316L stainless steel and cobalt-chromium and platinum-chromium alloys are widely used platforms for coronary stents. These alloys also contain nickel (Ni), which reportedly induces allergic reactions in some subjects and is known to have various cellular effects. The effects of Ni on neointima formation after stent implantation remain unknown, however. We developed coronary stents made of Ni-free high-nitrogen austenitic stainless steel prepared using a N 2 -gas pressurized electroslag remelting (P-ESR) process. Neointima formation and inflammatory responses following stent implantation in porcine coronary arteries were then compared between the Ni-free and SUS316L stainless steel stents. We found significantly less neointima formation and inflammation in arteries implanted with Ni-free stents, as compared to SUS316L stents. Notably, Ni 2+ was eluted into the medium from SUS316L but not from Ni-free stainless steel. Mechanistically, Ni 2+ increased levels of hypoxia inducible factor protein-1 α (HIF-1 α ) and its target genes in cultured smooth muscle cells. HIF-1 α and their target gene levels were also increased in the vascular wall at SUS316L stent sites but not at Ni-free stent sites. The Ni-free stainless steel coronary stent reduces neointima formation, in part by avoiding activation of inflammatory processes via the Ni-HIF pathway. The Ni-free-stainless steel stent is a promising new coronary stent platform.

  3. Mechanisms of nickel toxicity in microorganisms

    PubMed Central

    Macomber, Lee

    2014-01-01

    Summary Nickel has long been known to be an important human toxicant, including having the ability to form carcinomas, but until recently nickel was believed to be an issue only to microorganisms living in nickel-rich serpentine soils or areas contaminated by industrial pollution. This assumption was overturned by the discovery of a nickel defense system (RcnR/RcnA) found in microorganisms that live in a wide range of environmental niches, suggesting that nickel homeostasis is a general biological concern. To date, the mechanisms of nickel toxicity in microorganisms and higher eukaryotes are poorly understood. In this review, we summarize nickel homeostasis processes used by microorganisms and highlight in vivo and in vitro effects of exposure to elevated concentrations of nickel. On the basis of this evidence we propose four mechanisms of nickel toxicity: 1) nickel replaces the essential metal of metalloproteins, 2) nickel binds to catalytic residues of non-metalloenzymes; 3) nickel binds outside the catalytic site of an enzyme to inhibit allosterically, and 4) nickel indirectly causes oxidative stress. PMID:21799955

  4. The electrical resistance of gold-capped chromium thin films

    NASA Astrophysics Data System (ADS)

    Ohashi, Masashi; Sawabu, Masaki; Ohashi, Kohei; Miyagawa, Masahiro; Maeta, Kae; Kubota, Takahide; Takanashi, Koki

    2018-03-01

    We studied the electrical resistance of polycrystalline chromium films capped by a gold layer. No anomaly was detected by resistance measurements of 10 nm thick film around room temperature, indicating that the antiferromagnetic interaction may be suppressed as decreasing the thickness of the chromium film. The sheet resistance Rs (T) curves differ from polycrystalline chromium films in previous studies because of the electrical current flows through a gold capping layer. On the other hand, the resistance drop is observed at T C = 1.15±0.05 K as that of polycrystalline chromium films in the previous report. It means that such resistance drop is not related to the chromium oxide layer on a polycrystalline chromium films. However, it is difficult to conclude that superconducting transition occurs because of the large residual resistance below the temperature where the resistance drop is observed.

  5. BK/TD models for analyzing in vitro impedance data on cytotoxicity.

    PubMed

    Teng, S; Barcellini-Couget, S; Beaudouin, R; Brochot, C; Desousa, G; Rahmani, R; Pery, A R R

    2015-06-01

    The ban of animal testing has enhanced the development of new in vitro technologies for cosmetics safety assessment. Impedance metrics is one such technology which enables monitoring of cell viability in real time. However, analyzing real time data requires moving from static to dynamic toxicity assessment. In the present study, we built mechanistic biokinetic/toxicodynamic (BK/TD) models to analyze the time course of cell viability in cytotoxicity assay using impedance. These models account for the fate of the tested compounds during the assay. BK/TD models were applied to analyze HepaRG cell viability, after single (48 h) and repeated (4 weeks) exposures to three hepatotoxic compounds (coumarin, isoeugenol and benzophenone-2). The BK/TD models properly fit the data used for their calibration that was obtained for single or repeated exposure. Only for one out of the three compounds, the models calibrated with a single exposure were able to predict repeated exposure data. We therefore recommend the use of long-term exposure in vitro data in order to adequately account for chronic hepatotoxic effects. The models we propose here are capable of being coupled with human biokinetic models in order to relate dose exposure and human hepatotoxicity. Copyright © 2015 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  6. Roasting and leaching behaviors of vanadium and chromium in calcification roasting-acid leaching of high-chromium vanadium slag

    NASA Astrophysics Data System (ADS)

    Wen, Jing; Jiang, Tao; Zhou, Mi; Gao, Hui-yang; Liu, Jia-yi; Xue, Xiang-xin

    2018-05-01

    Calcification roasting-acid leaching of high-chromium vanadium slag (HCVS) was conducted to elucidate the roasting and leaching behaviors of vanadium and chromium. The effects of the purity of CaO, molar ratio between CaO and V2O5 ( n(CaO)/ n(V2O5)), roasting temperature, holding time, and the heating rate used in the oxidation-calcification processes were investigated. The roasting process and mechanism were analyzed by X-ray diffraction (XRD), scanning electron microscopy (SEM), and thermogravimetry-differential scanning calorimetry (TG-DSC). The results show that most of vanadium reacted with CaO to generate calcium vanadates and transferred into the leaching liquid, whereas almost all of the chromium remained in the leaching residue in the form of (Fe0.6Cr0.4)2O3. Variation trends of the vanadium and chromium leaching ratios were always opposite because of the competitive reactions of oxidation and calcification between vanadium and chromium with CaO. Moreover, CaO was more likely to combine with vanadium, as further confirmed by thermodynamic analysis. When the HCVS with CaO added in an n(CaO)/ n(V2O5) ratio of 0.5 was roasted in an air atmosphere at a heating rate of 10°C/min from room temperature to 950°C and maintained at this temperature for 60 min, the leaching ratios of vanadium and chromium reached 91.14% and 0.49%, respectively; thus, efficient extraction of vanadium from HCVS was achieved and the leaching residue could be used as a new raw material for the extraction of chromium. Furthermore, the oxidation and calcification reactions of the spinel phases occurred at 592 and 630°C for n(CaO)/ n(V2O5) ratios of 0.5 and 5, respectively.

  7. Technology Demonstration of the Zero Emissions Chromium Electroplating System

    DTIC Science & Technology

    2008-02-01

    Phase I trivalent chromium results ................................................................... 23 18 Phase II total chromium in PRD fluid results...0 xa B D F H J L Sam pies Figure 16. Phase II iron results. ERDC/CERL TR-05-35, Vol. 1 23 Trivalent Chromium Phase I Analysis for Phase I was...with the samples. Each sample was analyzed twice, and an average was computed. Figure 17 shows the results. ANAD has specified that Trivalent Chromium

  8. Comparison of Ultrasound-Assisted and Regular Leaching of Vanadium and Chromium from Roasted High Chromium Vanadium Slag

    NASA Astrophysics Data System (ADS)

    Wen, Jing; Jiang, Tao; Gao, Huiyang; Liu, Yajing; Zheng, Xiaole; Xue, Xiangxin

    2018-02-01

    Ultrasound-assisted leaching (UAL) was used for vanadium and chromium leaching from roasted material obtained by the calcification roasting of high-chromium-vanadium slag. UAL was compared with regular leaching. The effect of the leaching time and temperature, acid concentration, and liquid-solid ratio on the vanadium and chromium leaching behaviors was investigated. The UAL mechanism was determined from particle-size-distribution and microstructure analyses. UAL decreased the reaction time and leaching temperature significantly. Furthermore, 96.67% vanadium and less than 1% chromium were leached at 60°C for 60 min with 20% H2SO4 at a liquid-solid ratio of 8, which was higher than the maximum vanadium leaching rate of 90.89% obtained using regular leaching at 80°C for 120 min. Ultrasonic waves broke and dispersed the solid sample because of ultrasonic cavitation, which increased the contact area of the roasted sample and the leaching medium, the solid-liquid mass transfer, and the vanadium leaching rate.

  9. Chromium(VI)

    Integrated Risk Information System (IRIS)

    TOXICOLOGICAL REVIEW OF HEXAVALENT CHROMIUM ( CAS No . 18540 - 29 - 9 ) In Support of Summary Information on the Integrated Risk Information System ( IRIS ) August 1998 U.S . Environmental Protection Agency Washington , DC DISCLAIMER This document has been reviewed in accordance with U.S . Env

  10. Mineral resource of the month: Chromium

    USGS Publications Warehouse

    Schulte, Ruth

    2018-01-01

    Although chromium is a metal, it does not occur naturally in metallic form. Chromium can be found in many minerals, but the only economically significant chromium-bearing mineral is chromite. Chromite has been mined from four different deposit types: stratiform chromite, podiform chromite, placer chromite, and laterite deposits. Most of the world's resources, however, are located in stratiform chromite deposits, such as the Bushveld Complex in South Africa. The economic potential of chromite resources depends on the thickness and continuity of the deposit and on the grade of the ore. Many of the major stratiform chromite deposits also contain economic levels of platinum, paladium, rhodium, osmium, iridium, and ruthenium.

  11. Hexavalent Chromium Free Coatings Projects for Aerospace Applications

    DTIC Science & Technology

    2012-08-01

    1-Evaluate trivalent chromium pretreatment (TCP) for use on aluminum  2-Evaluate three hexavalent chrome free alternatives to DoD-P-15328 wash...UNCLASSIFIED UNCLASSIFIED Hexavalent Chromium Free Coatings Projects for Aerospace Applications Report Documentation Page Form...COVERED 00-00-2012 to 00-00-2012 4. TITLE AND SUBTITLE Hexavalent Chromium Free Coatings Projects for Aerospace Applications 5a. CONTRACT NUMBER

  12. Safety and immunogenicity of a single intramuscular dose of a tetanus-diphtheria toxoid (Td) vaccine (BR-TD-1001) in healthy Korean adult subjects.

    PubMed

    Hong, Taegon; Chung, Yong-Ju; Kim, Tae-Yeon; Kim, Ik-Hwan; Choe, Yong-Kyung; Lee, Jongtae; Jeon, Sangil; Han, Seunghoon; Yim, Dong-Seok

    2015-01-01

    BR-TD-1001 was developed as a booster for the immunity maintenance of diphtheria and tetanus. The aim of this study was to evaluate the safety and immunogenicity of BR-TD-1001 (test vaccine) in comparison with placebo and an active comparator in healthy Korean adults. A randomized, double-blind, placebo-controlled, active comparator, phase I clinical trial was conducted. Fifty subjects were randomly assigned to one of 3 treatment groups in a ratio of 2:2:1, and were administered a single intramuscular dose of test vaccine, active comparator, or placebo, respectively. All subjects were monitored for 4 weeks after injection. The antibody titers of the patients 2 and 4 weeks after vaccination were compared with the baseline. The frequencies of all adverse events including adverse drug reactions in the test group were not statistically different from those of the other treatment groups (P = 0.4974, 0.3061). No serious adverse event occurred, and no subject was withdrawn from the study for safety. The seroprotection rates against both tetanus and diphtheria at 4 weeks after vaccination were over 0.95. For anti-tetanus antibody, the geometric mean titer in the test group was significantly higher than those of the other groups (P = 0.0364, 0.0033). The geometric mean titer of anti-diphtheria antibody in the test group was significantly higher than the value of the placebo (P = 0.0347) while it was not for the value of the active comparator (P = 0.8484). In conclusion, BR-TD-1001 was safe, well-tolerated, and showed sufficient immunogenicity as a booster for diphtheria and tetanus.

  13. 29 CFR 1915.1026 - Chromium (VI).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... present from skin or eye contact with chromium (VI), the employer shall provide appropriate personal... clothing and equipment should be laundered or cleaned in a manner that minimizes skin or eye contact with... shall provide change rooms in conformance with 29 CFR 1910.141. Where skin contact with chromium (VI...

  14. A Double-blind, Randomized Pilot Trial of Chromium Picolinate for Binge Eating Disorder: Results of the Binge Eating and Chromium (BEACh) Study

    PubMed Central

    Brownley, Kimberly A.; Holle, Ann Von; Hamer, Robert M.; Via, Maria La; Bulik, Cynthia M.

    2015-01-01

    Objective Chromium treatment has been shown to improve mood, appetite, and glucose regulation in various psychiatric and medical patient populations. The authors propose that chromium may be useful in the treatment of binge eating disorder (BED). Method Twenty-four overweight adults with BED were enrolled in a 6-month double-blind placebo-controlled trial and randomly assigned to receive either 1000mcg chromium/day (“high dose”; n=8) or 600mcg chromium/day (“moderate dose”; n=9) as chromium picolinate or placebo (n=7). Mixed linear regression models were used to estimate mean change in binge frequency and related psychopathology, weight, symptoms of depression, and fasting glucose. Results Fasting glucose was significantly reduced in both chromium groups compared to the placebo group; similarly, numerically, but not significantly, greater reductions in binge frequency, weight, and symptoms of depression were observed in those treated with chromium versus placebo, although statistical power was limited in this pilot trial. For fasting glucose, the findings suggest a dose response with larger effects in the high dose compared to moderate dose group. Conclusion These initial findings support further larger trials to determine chromium’s efficacy in maintaining normal glucose regulation, reducing binge eating and related psychopathology, promoting modest weight loss, and reducing symptoms of depression in individuals with BED. Studies designed to link the clinical effects of chromium with changes in underlying insulin, serotonin, and dopamine pathways may be especially informative. If efficacious, chromium supplementation may provide a useful, low-cost alternative to or augmentation strategy for selective serotonin reuptake inhibitors, which have partial efficacy in BED. ClinicalTrials.gov NCT00904306. PMID:23751236

  15. Electrodeposition of Dense Chromium Coatings from Molten Salt Electrolytes

    DTIC Science & Technology

    1991-04-01

    AD-A235 978 . JUN 03 391 ELECTRODEPOSITION OF DENSE CHROMIUM COATINGS FROM MOLTEN SALT ELECTROLYTES Final Technical Report J t ]Vgca or by ~ 4 OTC... molten salts , pulsed currents, electrodeposition. 2. The results, on the electrodeposition of dense chromium coatings from molten salt electrolytes... salts dissolved in molten salts using the cell Cl2/C/!Cr 2 + in LiCI-KCI//Cr metal The chromium ions are introduced by anodizing a piece of chromium and

  16. Separation and Precipitation of Nickel from Acidic Sulfate Leaching Solution of Molybdenum-Nickel Black Shale by Potassium Nickel Sulfate Hexahydrate Crystallization

    NASA Astrophysics Data System (ADS)

    Deng, Zhigan; Wei, Chang; Fan, Gang; Li, Xingbin; Li, Minting; Li, Cunxiong

    2018-02-01

    Nickel was separated and precipitated with potassium nickel sulfate hexahydrate [K2Ni(SO4)2·6H2O] from acidic sulfate solution, a leach solution from molybdenum-nickel black shale. The effects of the potassium sulfate (K2SO4) concentration, crystallization temperature, solution pH, and crystallization time on nickel(II) recovery and iron(III) precipitation were investigated, revealing that nickel and iron were separated effectively. The optimum parameters were K2SO4 concentration of 200 g/L, crystallization temperature of 10°C, solution pH of 0.5, and crystallization time of 24 h. Under these conditions, 97.6% nickel(II) was recovered as K2Ni(SO4)2·6H2O crystals while only 2.0% of the total iron(III) was precipitated. After recrystallization, 98.4% pure K2Ni(SO4)2·6H2O crystals were obtained in the solids. The mother liquor was purified by hydrolysis-precipitation followed by cooling, and more than 99.0% K2SO4 could be crystallized. A process flowsheet was developed to separate iron(III) and nickel(II) from acidic-sulfate solution.

  17. Nickel allergy in a Danish population 25 years after the first nickel regulation.

    PubMed

    Ahlström, Malin G; Menné, Torkil; Thyssen, Jacob P; Johansen, Jeanne D

    2017-06-01

    Nickel in metallic items has been regulated in Denmark since 1990; however, 10% of young Danish women are still sensitized to nickel. There is a need for continuous surveillance of the effect of regulation. To identify current self-reported metallic exposures leading to dermatitis in nickel-allergic patients, and the minimum contact time needed for dermatitis to occur. A questionnaire was sent to all patients who reacted positively to nickel sulfate 5% pet. within the last 5 years at the Department of Dermatology and Allergy, Gentofte Hospital. The response rate was 63.2%. Earrings were the foremost cause of dermatitis after the EU Nickel Directive had been implemented, followed by other jewellery, buttons on clothing, belt buckles, and wrist watches. Dermatitis reactions within 10 min of contact were reported by 21.4% of patients, and dermatitis reactions within 30 min of contact were reported by 30.7% of patients. Nickel exposures that led to the implementation of a nickel regulation seem to persist. The durations of contact with metallic items to fall under the current REACH regulation of nickel correspond well with the results of this study. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Status of nickel/zinc and nickel/iron battery technology for electric vehicle applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yao, N.P.; Christianson, C.C.; Elliott, R.C.

    1980-01-01

    Significant progress in nickel/zinc and nickel/iron technology has been made towards achieving the battery technical performance goals necessary for widespread use of these battery systems in electric vehicle applications. This progress is reviewed. Nickel/zinc module test data have shown a specific energy of nearly 70 Whr/kg and a specific power of 130 W/kg. However, cycle life improvements are still needed (presently demonstrated capability of 120 cycles) and are expected to be demonstrated during 1980. Nickel/iron modules have demonstrated a specific energy of nearly 50 Wh/kg and a specific power of 100 W/kg. Indications are that improved performance in these areasmore » can be shown during 1980. Nickel/iron modules cycle lives of 300 have been achieved during early 1980 and testing continues. Energy efficiency has been improved from less than 50% to over 65%. Cost reduction (both initial and operating) continues to receive major emphasis at developers of both nickel/zinc and nickel/iron batteries in order to achieve the lowest possible life cycle cost to the battery user.« less

  19. Chromium in diet

    MedlinePlus

    ... and carbohydrates . It stimulates fatty acid and cholesterol synthesis, which are important for brain function and other body processes. Chromium also aids in insulin action and glucose metabolism.

  20. Biosorption of trivalent chromium on the brown seaweed biomass.

    PubMed

    Yun, Y S; Park, D; Park, J M; Volesky, B

    2001-11-01

    Biosorption has attracted attention as a cost-effective means for the treatment of metal-bearing wastewater. However, the mechanism of metal binding is not clearly understood, and consequently, modeling of the biosorption performance is still raising debates. In this study, the biosorption of trivalent chromium was investigated with protonated brown alga Ecklonia biomass as a model system. Titration of the biomass revealed that it contains at least three types of functional groups. The Fourier transform infrared spectrometry showed that the carboxyl group was the chromium-binding site within the pH range (pH 1-5) used in this study, where chromium does not precipitate. The pK value and the number of carboxyl groups were estimated to be 4.6 +/- 0.1 and 2.2 +/- 0.1 mmol/g, respectively. The equilibrium sorption isotherms determined at different solution pH indicated that the uptake of chromium increased significantly with increasing pH. A model for the description of chromium biosorption was developed incorporating the hydrolysis reactions that chromium undergoes in the aquatic phase. The model was able to predict the equilibrium sorption experimental data at different pH values and chromium concentrations. In addition, the speciation of the binding site as a function of the solution pH was predicted using the model in order to visualize the distribution of chromium ionic species on the binding site.