Sample records for tear faults insights

  1. The mechanics of fault-bend folding and tear-fault systems in the Niger Delta

    NASA Astrophysics Data System (ADS)

    Benesh, Nathan Philip

    This dissertation investigates the mechanics of fault-bend folding using the discrete element method (DEM) and explores the nature of tear-fault systems in the deep-water Niger Delta fold-and-thrust belt. In Chapter 1, we employ the DEM to investigate the development of growth structures in anticlinal fault-bend folds. This work was inspired by observations that growth strata in active folds show a pronounced upward decrease in bed dip, in contrast to traditional kinematic fault-bend fold models. Our analysis shows that the modeled folds grow largely by parallel folding as specified by the kinematic theory; however, the process of folding over a broad axial surface zone yields a component of fold growth by limb rotation that is consistent with the patterns observed in natural folds. This result has important implications for how growth structures can he used to constrain slip and paleo-earthquake ages on active blind-thrust faults. In Chapter 2, we expand our DEM study to investigate the development of a wider range of fault-bend folds. We examine the influence of mechanical stratigraphy and quantitatively compare our models with the relationships between fold and fault shape prescribed by the kinematic theory. While the synclinal fault-bend models closely match the kinematic theory, the modeled anticlinal fault-bend folds show robust behavior that is distinct from the kinematic theory. Specifically, we observe that modeled structures maintain a linear relationship between fold shape (gamma) and fault-horizon cutoff angle (theta), rather than expressing the non-linear relationship with two distinct modes of anticlinal folding that is prescribed by the kinematic theory. These observations lead to a revised quantitative relationship for fault-bend folds that can serve as a useful interpretation tool. Finally, in Chapter 3, we examine the 3D relationships of tear- and thrust-fault systems in the western, deep-water Niger Delta. Using 3D seismic reflection data and new

  2. Volcanism in slab tear faults is larger than in island-arcs and back-arcs.

    PubMed

    Cocchi, Luca; Passaro, Salvatore; Tontini, Fabio Caratori; Ventura, Guido

    2017-11-13

    Subduction-transform edge propagators are lithospheric tears bounding slabs and back-arc basins. The volcanism at these edges is enigmatic because it is lacking comprehensive geological and geophysical data. Here we present bathymetric, potential-field data, and direct observations of the seafloor on the 90 km long Palinuro volcanic chain overlapping the E-W striking tear of the roll-backing Ionian slab in Southern Tyrrhenian Sea. The volcanic chain includes arc-type central volcanoes and fissural, spreading-type centers emplaced along second-order shears. The volume of the volcanic chain is larger than that of the neighbor island-arc edifices and back-arc spreading center. Such large volume of magma is associated to an upwelling of the isotherms due to mantle melts upraising from the rear of the slab along the tear fault. The subduction-transform edge volcanism focuses localized spreading processes and its magnitude is underestimated. This volcanism characterizes the subduction settings associated to volcanic arcs and back-arc spreading centers.

  3. Tearing, segmentation, and backstepping of subduction in the Aegean: New insights from seismicity

    NASA Astrophysics Data System (ADS)

    Bocchini, G. M.; Brüstle, A.; Becker, D.; Meier, T.; van Keken, P. E.; Ruscic, M.; Papadopoulos, G. A.; Rische, M.; Friederich, W.

    2018-06-01

    This study revisits subduction processes at the Hellenic Subduction Zone (HSZ) including tearing, segmentation, and backstepping, by refining the geometry of the Nubian slab down to 150-180 km depth using well-located hypocentres from global and local seismicity catalogues. At the western termination of the HSZ, the Kefalonia Transform Fault marks the transition between oceanic and continental lithosphere subducting to the south and to the north of it, respectively. A discontinuity is suggested to exist between the two slabs at shallow depths. The Kefalonia Transform Fault is interpreted as an active Subduction-Transform-Edge-Propagator-fault formed as consequence of faster trench retreat induced by the subduction of oceanic lithosphere to the south of it. A model reconstructing the evolution of the subduction system in the area of Peloponnese since 34 Ma, involving the backstepping of the subduction to the back-side of Adria, provides seismological evidence that supports the single-slab model for the HSZ and suggests the correlation between the downdip limit of the seismicity to the amount of subducted oceanic lithosphere. In the area of Rhodes, earthquake hypocentres indicate the presence of a NW dipping subducting slab that rules out the presence of a NE-SW striking Subduction-Transform-Edge-Propagator-fault in the Pliny-Strabo trenches region. Earthquake hypocentres also allow refining the slab tear beneath southwestern Anatolia down to 150-180 km depth. Furthermore, the distribution of microseismicity shows a first-order slab segmentation in the region between Crete and Karpathos, with a less steep and laterally wider slab segment to the west and a steeper and narrower slab segment to the east. Thermal models indicate the presence of a colder slab beneath the southeastern Aegean that leads to deepening of the intermediate-depth seismicity. Slab segmentation affects the upper plate deformation that is stronger above the eastern slab segment and the seismicity

  4. Human tears reveal insights into corneal neovascularization.

    PubMed

    Zakaria, Nadia; Van Grasdorff, Sigi; Wouters, Kristien; Rozema, Jos; Koppen, Carina; Lion, Eva; Cools, Nathalie; Berneman, Zwi; Tassignon, Marie-José

    2012-01-01

    Corneal neovascularization results from the encroachment of blood vessels from the surrounding conjunctiva onto the normally avascular cornea. The aim of this study is to identify factors in human tears that are involved in development and/or maintenance of corneal neovascularization in humans. This could allow development of diagnostic tools for monitoring corneal neovascularization and combination monoclonal antibody therapies for its treatment. In an observational case-control study we enrolled a total of 12 patients with corneal neovascularization and 10 healthy volunteers. Basal tears along with reflex tears from the inferior fornix, superior fornix and using a corneal bath were collected along with blood serum samples. From all patients, ocular surface photographs were taken. Concentrations of the pro-angiogenic cytokines interleukin (IL)-6, IL-8, Vascular Endothelial Growth Factor (VEGF), Monocyte Chemoattractant Protein 1 (MCP-1) and Fas Ligand (FasL) were determined in blood and tear samples using a flow cytometric multiplex assay. Our results show that the concentration of pro-angiogenic cytokines in human tears are significantly higher compared to their concentrations in serum, with highest levels found in basal tears. Interestingly, we could detect a significantly higher concentration of IL- 6, IL-8 and VEGF in localized corneal tears of patients with neovascularized corneas when compared to the control group. This is the first study of its kind demonstrating a significant difference of defined factors in tears from patients with neovascularized corneas as compared to healthy controls. These results provide the basis for future research using animal models to further substantiate the role of these cytokines in the establishment and maintenance of corneal neovascularization.

  5. Human Tears Reveal Insights into Corneal Neovascularization

    PubMed Central

    Wouters, Kristien; Rozema, Jos; Koppen, Carina; Lion, Eva; Cools, Nathalie; Berneman, Zwi; Tassignon, Marie-José

    2012-01-01

    Corneal neovascularization results from the encroachment of blood vessels from the surrounding conjunctiva onto the normally avascular cornea. The aim of this study is to identify factors in human tears that are involved in development and/or maintenance of corneal neovascularization in humans. This could allow development of diagnostic tools for monitoring corneal neovascularization and combination monoclonal antibody therapies for its treatment. In an observational case-control study we enrolled a total of 12 patients with corneal neovascularization and 10 healthy volunteers. Basal tears along with reflex tears from the inferior fornix, superior fornix and using a corneal bath were collected along with blood serum samples. From all patients, ocular surface photographs were taken. Concentrations of the pro-angiogenic cytokines interleukin (IL)-6, IL-8, Vascular Endothelial Growth Factor (VEGF), Monocyte Chemoattractant Protein 1 (MCP-1) and Fas Ligand (FasL) were determined in blood and tear samples using a flow cytometric multiplex assay. Our results show that the concentration of pro-angiogenic cytokines in human tears are significantly higher compared to their concentrations in serum, with highest levels found in basal tears. Interestingly, we could detect a significantly higher concentration of IL- 6, IL-8 and VEGF in localized corneal tears of patients with neovascularized corneas when compared to the control group. This is the first study of its kind demonstrating a significant difference of defined factors in tears from patients with neovascularized corneas as compared to healthy controls. These results provide the basis for future research using animal models to further substantiate the role of these cytokines in the establishment and maintenance of corneal neovascularization. PMID:22590547

  6. Stress transfer among en echelon and opposing thrusts and tear faults: Triggering caused by the 2003 Mw = 6.9 Zemmouri, Algeria, earthquake

    USGS Publications Warehouse

    Lin, J.; Stein, R.S.; Meghraoui, M.; Toda, S.; Ayadi, A.; Dorbath, C.; Belabbes, S.

    2011-01-01

    The essential features of stress interaction among earthquakes on en echelon thrusts and tear faults were investigated, first through idealized examples and then by study of thrust faulting in Algeria. We calculated coseismic stress changes caused by the 2003 Mw = 6.9 Zemmouri earthquake, finding that a large majority of the Zemmouri afterslip sites were brought several bars closer to Coulomb failure by the coseismic stresses, while the majority of aftershock nodal planes were brought closer to failure by an average of ~2 bars. Further, we calculated that the shallow portions of the adjacent Thenia tear fault, which sustained ~0.25 m slip, were brought >2 bars closer to failure. We calculated that the Coulomb stress increased by 1.5 bars on the deeper portions of the adjacent Boumerdes thrust, which lies just 10–20 km from the city of Algiers; both the Boumerdes and Thenia faults were illuminated by aftershocks. Over the next 6 years, the entire south dipping thrust system extending 80 km to the southwest experienced an increased rate of seismicity. The stress also increased by 0.4 bar on the east Sahel thrust fault west of the Zemmouri rupture. Algiers suffered large damaging earthquakes in A.D. 1365 and 1716 and is today home to 3 million people. If these shocks occurred on the east Sahel fault and if it has a ~2 mm/yr tectonic loading rate, then enough loading has accumulated to produce a Mw = 6.6–6.9 shock today. Thus, these potentially lethal faults need better understanding of their slip rate and earthquake history.

  7. Tears and transformation: feeling like crying as an indicator of insightful or “aesthetic” experience with art

    PubMed Central

    Pelowski, Matthew

    2015-01-01

    This paper explores a fundamental similarity between cognitive models for crying and conceptions of insight, enlightenment or, in the context of art, “aesthetic experience.” All of which center on a process of initial discrepancy, followed by schema change, and conclude in a proposed adjustment or “transformation” of one's self image/world-view. Because tears are argued to mark one of the only physical indicators of this cognitive outcome, and because the process is particularly salient in examples with art, I argue that crying may provide an intriguing marker for empirical study of art experience. To explore this parallel, I offer a review of crying theory as well as of tearful cases with art, pointing out the key cognitive elements. I then introduce an expanded crying model, based upon our recent model of art experience which does consider insight and adjustment or application of the self. I also consider multiple emotional and evaluative factors, which may co-vary with crying response. This theoretical discussion is then applied in three exploratory, survey-based studies conducted within U.K., Japan and U.S. museums, and including what is claimed to be the 20th century's most tear-inducing abstract paintings. Results showed—with cross-cultural consistency—significant relation between “feeling like crying” and a collection of responses posited to indicate a full progression to aesthetic experience, as well as to positive assessment of artwork goodness, beauty, understanding of meaning, and to final reported self reflection and epiphany. I argue that, beyond the question of why we may cry, by considering the implications of what tears may indicate within information processing, feeling like crying may indeed offer a compelling basis for empirically identifying outcomes of perceptual (art) experience. PMID:26257671

  8. Magnetic insights on seismogenic processes from scientific drilling of fault

    NASA Astrophysics Data System (ADS)

    Ferre, E. C.; Chou, Y. M.; Aubourg, C. T.; Li, H.; Doan, M. L.; Townend, J.; Sutherland, R.; Toy, V.

    2017-12-01

    Modern investigations through scientific drilling of recently seismogenic faults have provided remarkable insights on the physics of rupture processes. Following devastating earthquakes, several drilling programs focused since 1995 on the Nojima, Chelungpu, San Andreas, Wenchuan, Nankai Trough, Japan Trench and New Zealand Alpine faults. While these efforts were all crowned with success largely due to the multidisciplinarity of investigations, valuable insights were gained from rock magnetism and paleomagnetism and deserve to be highlighted. Continuous logging of magnetic properties allows detection of mineralogical and chemical changes in the host rock and fault zone particularly in slip zones, whether these are caused by frictional melting, elevation of temperature, ultracataclasis, or post-seismic fluid rock interaction. Further magnetic experiments on discrete samples including magnetic susceptibility, natural remanent magnetization, hysteresis properties, isothermal remanent magnetization acquisition and first order reversal curves, provide additional constrains on the nature, concentration and grain size of magnetic carriers. These experiments typically also inform on magnetization processes by thermal, chemical, or electrical mechanisms. Magnetic fabrics are generally not investigated on fault rocks from drill cores primarily in an effort to conserve the recovered core. However, recent methodological developments now would allow chemically non-destructive anisotropy of magnetic susceptibility (AMS) measurements to be performed on small 3.5 mm cubes. The mini-AMS method could provide crucial information on the kinematics of frictional melts produced during recent or ancient earthquakes and therefore would constrain the corresponding focal mechanisms. Finally, demagnetization experiments of the natural remanent magnetization (NRM) are one of the most powerful items in the magnetic toolkit because they provide chronological constrains on magnetization processes

  9. Observations of Displacement-driven Maturation along a Subduction-Transform Edge Propagator Fault

    NASA Astrophysics Data System (ADS)

    Neely, J. S.; Furlong, K. P.

    2016-12-01

    The Solomon Islands-Vanuatu composite subduction zone represents a tectonically complex region along the Pacific-Australia plate boundary in the southwest Pacific Ocean. Here the Australia plate subducts under the Pacific plate in two parts - the Solomon Trench and the Vanuatu Trench - with the two segments separated by a transform fault produced by a tear in the approaching Australia plate. As a result of the Australia plate tearing, the two subducting sections are offset by the 280 km long San Cristobal Trough (SCT) transform fault, which acts as a Subduction-Transform Edge Propagator (STEP) fault. The formation of this transform fault provides an opportunity to study the evolution of a newly created transform plate boundary. As distance from the tear increases, both the magnitude and frequency of earthquakes along the transform increase reflecting the coalescence of fault segments into a through-going structure. Over the past few decades, there have been several instances of larger magnitude earthquakes migrating westward along the STEP through a rapid succession of events. A recent May 2015 sequence of MW 6.8, MW 6.9, and MW 6.8 earthquakes followed this pattern, with an east to west migration over three days. However, neither this 2015 sequence, nor a previous 1993 progression, ruptured into or nucleated a large earthquake within the region near the tear. SCT sequence termination outside the region of the newly formed fault occurs even though Coulomb Failure Stress analyses reveal that the tear end of the SCT is positively loaded for failure by the earthquake sequence. Changing seismicity patterns along the SCT are also mapped by b-value variations that correspond to the rupture patterns of these propagating sequences. These seismicity pattern changes along the SCT reveal a fault maturation process with strain localization driven by cumulative slip corresponding to approximately 80-100 km of displacement.

  10. Tear-Film Evaporation Rate from Simultaneous Ocular-Surface Temperature and Tear-Breakup Area.

    PubMed

    Dursch, Thomas J; Li, Wing; Taraz, Baseem; Lin, Meng C; Radke, Clayton J

    2018-01-01

    A corneal heat-transfer model is presented to quantify simultaneous measurements of fluorescein tear-breakup area (TBA) and ocular-surface temperature (OST). By accounting for disruption of the tear-film lipid layer (TFLL), we report evaporation rates through lipid-covered tear. The modified heat-transfer model provides new insights into evaporative dry eye. A quantitative analysis is presented to assess human aqueous tear evaporation rate (TER) through intact TFLLs from simultaneous in vivo measurement of time-dependent infrared OST and fluorescein TBA. We interpret simultaneous OST and TBA measurements using an extended heat-transfer model. We hypothesize that TBAs are ineffectively insulated by the TFLL and therefore exhibit higher TER than does that for a well-insulting TFLL-covered tear. As time proceeds, TBAs increase in number and size, thereby increasing the cornea area-averaged TER and decreasing OST. Tear-breakup areas were assessed from image analysis of fluorescein tear-film-breakup video recordings and are included in the heat-transfer description of OST. Model-predicted OSTs agree well with clinical experiments. Percent reductions in TER of lipid-covered tear range from 50 to 95% of that for pure water, in good agreement with literature. The physical picture of noninsulating or ruptured TFLL spots followed by enhanced evaporation from underlying cooler tear-film ruptures is consistent with the evaporative-driven mechanism for local tear rupture. A quantitative analysis is presented of in vivo TER from simultaneous clinical measurement of transient OST and TBA. The new heat-transfer model accounts for increased TER through expanding TBAs. Tear evaporation rate varies strongly across the cornea because lipid is effectively missing over tear-rupture troughs. The result is local faster evaporation compared with nonruptured, thick lipid-covered tear. Evaporative-driven tear-film ruptures deepen to a thickness where fluorescein quenching commences and local

  11. Classification of ulnar triangular fibrocartilage complex tears. A treatment algorithm for Palmer type IB tears.

    PubMed

    Atzei, A; Luchetti, R; Garagnani, L

    2017-05-01

    The classical definition of 'Palmer Type IB' triangular fibrocartilage complex tear, includes a spectrum of clinical conditions. This review highlights the clinical and arthroscopic criteria that enable us to categorize five classes on a treatment-oriented classification system of triangular fibrocartilage complex peripheral tears. Class 1 lesions represent isolated tears of the distal triangular fibrocartilage complex without distal radio-ulnar joint instability and are amenable to arthroscopic suture. Class 2 tears include rupture of both the distal triangular fibrocartilage complex and proximal attachments of the triangular fibrocartilage complex to the fovea. Class 3 tears constitute isolated ruptures of the proximal attachment of the triangular fibrocartilage complex to the fovea; they are not visible at radio-carpal arthroscopy. Both Class 2 and Class 3 tears are diagnosed with a positive hook test and are typically associated with distal radio-ulnar joint instability. If required, treatment is through reattachment of the distal radio-ulnar ligament insertions to the fovea. Class 4 lesions are irreparable tears due to the size of the defect or to poor tissue quality and, if required, treatment is through distal radio-ulnar ligament reconstruction with tendon graft. Class 5 tears are associated with distal radio-ulnar joint arthritis and can only be treated with salvage procedures. This subdivision of type IB triangular fibrocartilage complex tear provides more insights in the pathomechanics and treatment strategies. II.

  12. Tear geometry at active STEPs: an analogue model approach

    NASA Astrophysics Data System (ADS)

    Broerse, Taco; Sokoutis, Dimitrios; Willingshofer, Ernst; Govers, Rob

    2017-04-01

    At the lateral end of a subduction zone, tearing of lithosphere is the result of subduction of oceanic lithosphere while adjacent buoyant continental lithosphere stays at the surface. The location of lithospheric tearing is called a Subduction-Transform-Edge-Propagator (STEP), which continuously extends the plate boundary between overriding plate and continental lithosphere. One of our areas of interest is the southern Caribbean where Atlantic lithosphere subducts below the Caribbean plate. Mantle tomography suggests a clear southern edge of the Lesser Antilles slab, which makes the boundary between the Caribbean and South America a clear STEP candidate. At the surface, the San Sebastián/El Pilar fault zone forms the plate boundary between the Caribbean and South America and the active STEP is located near Trinidad. For the deeper part of the damage/shear zone, some information is available from a recent 3D gravity study: significant lateral variability in densities of the lithospheric mantle to the south of the STEP fault zone. The low-density zone may result from higher sub-crustal temperatures, such as would arise from an asthenospheric window resulting from detachment. Interpreted in this way, the mantle part of the damage zone may be 200-250 km wide. So, while the location of the plate boundary at the surface is relatively well resolved, little is known about the deeper continuation of the active STEP in the mantle lithosphere. We study the evolution of the tearing process at a STEP using analogue models. In our models we use silicone putty (lithosphere) and glucose (asthenosphere). Solely gravitational forces resulting from density differences between oceanic lithosphere and asthenosphere drive our model. Lithospheric tearing commences after subduction has initiated. The geometry of the tear varies with the rheology of the lithosphere and asthenosphere, particularly Newtonian versus power-law. We investigate the dependence on model parameters of the width of

  13. New insights into seismic faulting during the 2008 Mw7.9 Wenchuan earthquake

    NASA Astrophysics Data System (ADS)

    Li, H.; Wang, H.; Si, J.; Sun, Z.; Pei, J.; Lei, Z.; He, X.

    2017-12-01

    The WFSD project was implemented promptly after the 2008 Mw 7.9 Wenchuan earthquake. A series of research results on the seismogenic structure, fault deformation, sliding mechanism and fault healing have been obtained, which provide new insights into seismic faulting and mechanisms of the Wenchuan earthquake. The WFSD-1 and -2 drilling core profiles reveal that the Longmen Shan thrust belt is composed of multiple thrust sheets. The 2008 Wenchuan earthquake took place in such tectonic setting with strong horizontal shortening. The two ruptured faults have different deformation mechanisms. The Yingxiu-Beichuan fault (YBF) is a stick-slip fault characterized by fault gouge with high magnetic susceptibility, Guanxian-Anxian fault (GAF) with creeping features and characterized by fault gouge with low magnetic susceptibility. Two PSZs were found in WFSD-1 and -2 cores in the southern segment of YBF. The upper PSZ1 is a low-angle thrust fault characterized by coseisimc graphitization with an extremely low frictional coefficient. The lower PSZ2 is an oblique dextral-slip thrust fault characterized by frictional melt lubrication. In the northern segment of YBF, the PSZ in WFSD-4S cores shows a high-angle thrust feature with fresh melt as well. Therefore, the oblique dextral-slip thrust faulting with frictional melt lubrication is the main faulting of Wenchuan earthquake. Fresh melt with quenching texture was formed in Wenchuan earthquake implying vigorous fluid circulation occurred during the earthquake, which quenched high-temperature melt, hamper the aftermost fault slip and welding seismic fault. Therefore, fluids in the fault zone not only promotes fault weakening, but also suppress slipping in theWenchuan earthquake. The YBF has an extremely high hydraulic diffusivity (2.4×10-2 m2s-1), implying a vigorous fluid circulation in the Wenchuan fault zone. the permeability of YBF has reduced 70% after the shock, reflecting a rapid healing for the YBF. However, the water

  14. Geological features of Subduction Transfer Edge Propagator (STEP) faults, examples from the Betics and Rif

    NASA Astrophysics Data System (ADS)

    Booth-Rea, Guillermo; Pérez-Peña, Vicente; Azañón, José Miguel; de Lis Mancilla, Flor; Morales, Jose; Stich, Daniel; Giaconia, Flavio

    2014-05-01

    Most of the geological features of the Betics and Rif have resulted from slab tearing, edge delamination and punctual slab breakoff events between offset STEP faults. New P-reciever function data of the deep structure under the Betics and Rif have helped to map the deep boundaries of slab tearing and rupture in the area. Linking surface geological features with the deep structure shows that STEP faulting under the Betics occurred along ENE-WSW segments offset towards the south, probably do to the westward narrowing of the Tethys slab. The surface expression of STEP faulting at the Betics consists of ENE-WSW dextral strike-slip fault segments like the Crevillente, Alpujarras or Torcal faults that are interrupted by basins and elongated extensional domes were exhumed HP middle crust occurs. Exhumation of deep crust erases the effects of strike-slip faulting in the overlying brittle crust. Slab tearing affected the eastern Betics during the Tortonian to Messinian, producing the Fortuna and Lorca basins, and later propagated westward generating the end-Messinian to Pleistocene Guadix-Baza basins and the Granada Pliocene-Pleistocene depocentre. At present slab tearing is occurring beneath the Málaga depression, where the Torcal dextral strike-slip fault ends in a region of active distributed shortening and where intermediate depth seismicity occurs. STEP fault migration has occurred at average rates between 2 and 4 cm/yr since the late Miocene, producing a wave of alternating uplift-subsidence pulses. These initiate with uplift related to slab flexure, subsidence related to slab-pull, followed by uplift after rupture and ending with thermal subsidence. This "yo-yo" type tectonic evolution leads to the generation of endorheic basins that later evolve to exhorheic when they are uplifted and captured above the region where asthenospheric upwelling occurs.

  15. Thrust faults and related structures in the crater floor of Mount St. Helens volcano, Washington

    USGS Publications Warehouse

    Chadwick, W.W.; Swanson, D.A.

    1989-01-01

    A lava dome was built in the crater of Mount St. Helens by intermittent intrusion and extrusion of dacite lava between 1980 and 1986. Spectacular ground deformation was associated with the dome-building events and included the development of a system of radial cracks and tangential thrust faults in the surrounding crater floor. These cracks and thrusts, best developed and studied in 1981-1982, formed first and, as some evolved into strike-slip tear faults, influenced the subsequent geometry of thrusting. Once faulting began, deformation was localized near the thrust scarps and their bounding tear faults. The magnitude of displacements systematically increased before extrusions, whereas the azimuth and inclination of displacements remained relatively constant. The thrust-fault scarps were bulbous in profile, lobate in plan, and steepened during continued fault movement. The hanging walls of each thrust were increasingly disrupted as cumulative fault slip increased. -from Authors

  16. The influence of fault geometry and frictional contact properties on slip surface behavior and off-fault damage: insights from quasi-static modeling of small strike-slip faults from the Sierra Nevada, CA

    NASA Astrophysics Data System (ADS)

    Ritz, E.; Pollard, D. D.

    2011-12-01

    Geological and geophysical investigations demonstrate that faults are geometrically complex structures, and that the nature and intensity of off-fault damage is spatially correlated with geometric irregularities of the slip surfaces. Geologic observations of exhumed meter-scale strike-slip faults in the Bear Creek drainage, central Sierra Nevada, CA, provide insight into the relationship between non-planar fault geometry and frictional slip at depth. We investigate natural fault geometries in an otherwise homogeneous and isotropic elastic material with a two-dimensional displacement discontinuity method (DDM). Although the DDM is a powerful tool, frictional contact problems are beyond the scope of the elementary implementation because it allows interpenetration of the crack surfaces. By incorporating a complementarity algorithm, we are able to enforce appropriate contact boundary conditions along the model faults and include variable friction and frictional strength. This tool allows us to model quasi-static slip on non-planar faults and the resulting deformation of the surrounding rock. Both field observations and numerical investigations indicate that sliding along geometrically discontinuous or irregular faults may lead to opening of the fault and the formation of new fractures, affecting permeability in the nearby rock mass and consequently impacting pore fluid pressure. Numerical simulations of natural fault geometries provide local stress fields that are correlated to the style and spatial distribution of off-fault damage. We also show how varying the friction and frictional strength along the model faults affects slip surface behavior and consequently influences the stress distributions in the adjacent material.

  17. Reverse fault growth and fault interaction with frictional interfaces: insights from analogue models

    NASA Astrophysics Data System (ADS)

    Bonanno, Emanuele; Bonini, Lorenzo; Basili, Roberto; Toscani, Giovanni; Seno, Silvio

    2017-04-01

    The association of faulting and folding is a common feature in mountain chains, fold-and-thrust belts, and accretionary wedges. Kinematic models are developed and widely used to explain a range of relationships between faulting and folding. However, these models may result not to be completely appropriate to explain shortening in mechanically heterogeneous rock bodies. Weak layers, bedding surfaces, or pre-existing faults placed ahead of a propagating fault tip may influence the fault propagation rate itself and the associated fold shape. In this work, we employed clay analogue models to investigate how mechanical discontinuities affect the propagation rate and the associated fold shape during the growth of reverse master faults. The simulated master faults dip at 30° and 45°, recalling the range of the most frequent dip angles for active reverse faults that occurs in nature. The mechanical discontinuities are simulated by pre-cutting the clay pack. For both experimental setups (30° and 45° dipping faults) we analyzed three different configurations: 1) isotropic, i.e. without precuts; 2) with one precut in the middle of the clay pack; and 3) with two evenly-spaced precuts. To test the repeatability of the processes and to have a statistically valid dataset we replicate each configuration three times. The experiments were monitored by collecting successive snapshots with a high-resolution camera pointing at the side of the model. The pictures were then processed using the Digital Image Correlation method (D.I.C.), in order to extract the displacement and shear-rate fields. These two quantities effectively show both the on-fault and off-fault deformation, indicating the activity along the newly-formed faults and whether and at what stage the discontinuities (precuts) are reactivated. To study the fault propagation and fold shape variability we marked the position of the fault tips and the fold profiles for every successive step of deformation. Then we compared

  18. Crustal structure of the Ionian basin and eastern Sicily margin : results from a wide angle seismic survey and implication for the crustal nature and origin of the basin, and the recent tear fault location

    NASA Astrophysics Data System (ADS)

    Gutscher, M. A.; Dellong, D.; Klingelhoefer, F.; Kopp, H.; Graindorge, D.; Margheriti, L.; Moretti, M.

    2017-12-01

    In the Ionian Sea (Central Mediterranean) the slow convergence between Africa and Eurasia results in the formation of a narrow subduction zone. The nature of the crust and lithosphere of the subducting plate remain debated and could represent the last remnants of the Neo-Tethys ocean. The rifting mechanism that produced the Ionian basin are also still under discussion with the Malta escarpment representing a possible remnant of this opening. At present, this subduction is still retreating to the south-east (motion occurring since the last 35 Ma) but is confined to the narrow Ionian Basin. In order to accommodate slab roll-back, a major lateral slab tear fault is required. This fault is thought to propagate along the eastern Sicily margin but its precise location remains controversial. This study focuses on the deep crustal structure of the Eastern-Sicily margin and the Malta Escarpment by presenting two wide-angle velocity profiles crossing these structures roughly orthogonally. The data used for the forward velocity modeling were acquired onboard the R/V Meteor during the DIONYSUS cruise in 2014. The results image an oceanic crust within the Ionian basin as well as the deep structure of the Malta Escarpment which presents characteristics of a transform margin. A deep and asymmetrical sedimentary basin is imaged south of the Messina strait and seems to have opened in between the Calabrian and Peloritan continental terranes. The interpretation of the velocity models suggests that the tear fault is located east of the Malta Escarpment, along the Alfeo fault system.

  19. Photon correlation spectroscopy applied to tear analysis.

    PubMed

    Picarazzi, S; Lecchi, M; Pastori, V; D'Arienzo, M; Scotti, R; Tavazzi, S

    2017-09-01

    This study aims to deepen the knowledge on tear film properties by the development of a protocol for analyses of Photon Correlation Spectroscopy (PCS) on human tears and by the comparison between PCS results obtained on tears of contact lens wearers and non-wearers. Tears (5μL) were collected by a glass capillary. The analyses provide the hydrodynamic diameter of tear components by analyzing intensity fluctuations in time of scattered light. PCS appears a promising technique for studying tear features and for shedding light on specific eye conditions, such as on the clinical effects of CL wear. In fact, statistical difference (p<0.001) was found between the measured mean hydrodynamic diameter of tear components of wearers and non-wearers, the resulting value significantly higher for CL wearers. The scenario does not substantially change after (25±5)min from the CL removal. The difference is attributed to changes in the interactions between tear constituents due to CL wear. In order to get deeper insights on the influence of CL wear on aggregation and structure of tear components, a preliminary Electron Spin Resonance (ESR) investigation was performed, monitoring Fe 3+ species. ESR spectra on tears of both CL wearers and non-wearers showed the presence of intense signals, probably associated to iron (III) centers in proteins such as lactoferrin, and a weaker resonance attributable to Fe 3+ species interacting with S-S bridges of lysozyme. Differences in ESR spectra between CL wearers and non-wearers were detected and tentatively ascribed to changes in coordination or in local environment of Fe 3+ centers connected to aggregation phenomena induced by CL wear, which promote their interaction with other neighboring iron species. Copyright © 2017. Published by Elsevier B.V.

  20. Structure and microanalysis of tear film ferning of camel tears, human tears, and Refresh Plus.

    PubMed

    Am, Masmali; Ra, Fagehi; El-Naggar, Ahmad H; Tm, Almubrad

    2018-01-01

    This study aimed to investigate the tear ferning pattern and chemical elements of the tear film of camel tears compared with human tears and Refresh Plus eye lubricant. Refresh Plus was used as a control because it provides a healthy ferning pattern, due to the presence of an optimum ratio of carboxymethylcellulose (CMC) sodium and electrolytes. The main research focus is elucidating the viability of camel tear film in the dry, harsh environment of the desert. The tears were collected from five camels, five male desert workers (20-25 years old) at a small village located 100 km from Riyadh, Saudi Arabia, and five male subjects (20-25 years old) from Riyadh. A small drop (1 μl) of tears was dried on a glass slide and observed under a light (Olympus BX1) and scanning electron microscope (Inspect S50, Field Electron and Ion Company [FEI]). Energy-dispersive X-ray spectroscopy (EDS) of the tear film and Refresh Plus were investigated with a JEOL 1400 scanning transmission electron microscope. The camel tear film pattern was surrounded by thick, peripheral, homogenous layers containing small oily droplets, particles, and tiny branches in the tear ferning. The tear ferning of the camel was grade 0-1, whereas the tear ferning of human tears and Refresh Plus was grade 1-2. The mass percentage of chloride was highest in the camel tears. The mass percentage of potassium in the camel tears was greater than that in the human tears, but it was less than that in the Refresh Plus lubricant. Camel tears exhibit a better quality than human tears and Refresh Plus lubricant do. The presence of oily droplet-like structures at the periphery of tear ferning suggests that camel tear film may have a higher quality and quantity of minerals and lubricants, which may help the animal to avoid eye dryness. Future work is required to investigate the identification of the elements present in the peripheral and central part of the tear ferning.

  1. Effects of tear film dynamics on quality of vision.

    PubMed

    Koh, Shizuka; Tung, Cynthia I; Inoue, Yasushi; Jhanji, Vishal

    2018-06-15

    The precorneal tear film is maintained by blinking and exhibits different phases in the tear cycle. The tear film serves as the most anterior surface of the eye and plays an important role as a first refractive component of the eye. Alterations in tear film dynamics may cause both vision-related and ocular surface-related symptoms. Although the optical quality associated with the tear film dynamics previously received little attention, objective measurements of optical quality using wavefront sensors have enabled us to quantify optical aberrations induced by the tear film. This has provided an objective method for assessing reduced optical quality in dry eye; thus, visual disturbances were included in the definition of dry eye disease in the 2007 Dry Eye Workshop report. In addition, sequential measurements of wavefront aberrations have provided us with valuable insights into the dynamic optical changes associated with tear film dynamics. This review will focus on the current knowledge of the mechanisms of wavefront variations that are caused by different aspects of tear film dynamics: specifically, quality, quantity and properties of the tear film, demonstrating the respective effects of dry eye, epiphora and instillation of eye drops on the quality of vision. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. Meniscal tears missed on MR imaging: relationship to meniscal tear patterns and anterior cruciate ligament tears.

    PubMed

    De Smet, A A; Graf, B K

    1994-04-01

    MR imaging of the knee is a valuable technique for diagnosing meniscal tears, but some tears found at arthroscopy are not shown on MR imaging. The purpose of this study was to determine whether or not tears were more frequently missed in the presence of an anterior cruciate ligament tear or when tears had certain locations or configurations. We reviewed the original MR reports and surgical records of 400 patients who had both an MR examination and arthroscopy of the knee. Using chi 2 analysis, we examined how the sensitivity for detecting meniscal tears varied with the presence of a tear of the anterior cruciate ligament, with the location of the tear within the meniscus, and among six configurations of meniscal tears. We also studied whether sensitivity decreased with an increasing delay between MR examination and arthroscopy. In the presence of a tear of the anterior cruciate ligament, the sensitivity decreased from 0.97 to 0.88 (p = .016) for medial meniscal tears and from 0.94 to 0.69 (p = .0005) for lateral tears. The overall sensitivity for lateral meniscal tears was significantly less for posterior (p = .001) and peripheral (p = .005) tears than for other tear locations or configurations. The sensitivities did not significantly differ between tear locations and configurations in the medial meniscus or with an increasing delay until arthroscopy. Patients with a torn anterior cruciate ligament were more likely to have peripheral tears of the medial meniscus (p = .00004) and posterior (p = .0004) and peripheral (p = .04) tears of the lateral meniscus. Because of their location and configuration, meniscal tears associated with an anterior cruciate ligament injury are more difficult to detect on MR images than are tears in knees with an intact ligament. If a tear of the anterior cruciate ligament is detected, special attention should be given to the subtle peripheral tears that may be present in either meniscus, but most commonly in the posterior horn of the

  3. Quaternary fault-controlled volcanic vents and crustal thinning: new insights from the magma-rich Tyrrhenian passive margin (Italy)

    NASA Astrophysics Data System (ADS)

    Cardello, Giovanni Luca; Conti, Alessia; Consorti, Lorenzo; Do Couto, Damien

    2017-04-01

    The discover of monogenic Quaternary volcanic vents, that were recently mapped along major fault zones both inland and offshore the Tyrrhenian magma-rich passive margin, poses questions about: timing and role they had into Plio-Pleistocene crustal thinning with relevant consequences for the hazard assessment of an area inhabited by some 0.5 million people. The present-day margin is stretched over 100 km between the Volsci Range (VR) and the Pontian escarpment, being defined by moderate shallow seismicity (Mw≤4.6), relative high geothermal gradient and ongoing hydrothermal activity. Although major central volcanoes (e.g., Colli Albani), occurring at major fault intersections are well studied, smaller volcanic fields were so far unconstrained. Both field survey in the VR and offshore high-resolution geophysical data, allow us to: 1) better define the anatomy of the poorly known VR volcanic field; 2) furnish new insights on the regional Quaternary dynamics; 3) propose modes and reason of magma emplacement. The VR is composed of about 40 punctual and linear monogenic and mostly phreatomagmatic vents occurring at the edges of the Apennine carbonate fold-and-thrust belt and within the VR backbone. Volcanites are characterized by zeolitized to incoherent tuffs and surge deposits locally covered by lavas and slope deposits. Most explosive units host carbonate-rich lithics with different degrees of rounding and decarbonation, which frequently belong to Albian-Cenomanian aquifers. By comparing cross-section with lithic analyses we demonstrate that fragmentation, transport, progressive disintegration and decarbonation occur at multiple depths, depending on the fold-and-thrust belt setting. Thus, along the same vent zone, juvenile lithic composition proves repeated fragmentation within pressured-aquifers, testifying for fissural activity with implications for local seismic and volcanic assessment. Pyroclastic deposits occur as well in the Pontina and Fondi coastal plains at

  4. The tear turnover and tear clearance tests - a review.

    PubMed

    Garaszczuk, Izabela K; Montes Mico, Robert; Iskander, D Robert; Expósito, Alejandro Cerviño

    2018-03-01

    The aim is to provide a summary of methods available for the assessment of tear turnover and tear clearance rates. The review defines tear clearance and tear turnover and describes their implication for ocular surface health. Additionally, it describes main types of techniques for measuring tear turnover, including fluorescein tear clearance tests, techniques utilizing electromagnetic spectrum and tracer molecule and novel experimental techniques utilizing optical coherence tomography and fluorescein profilometry. Areas covered: Internet databases (PubMed, Science Direct, Google Scholar) and most frequently cited references were used as a principal resource of information on tear turnover rate and tear clearance rate, presenting methodologies and equipment, as well as their definition and implications for the anterior eye surface health and function. Keywords used for data-search were as follows: tear turnover, tear clearance, fluorescein clearance, scintigraphy, fluorophotometry, tear flow, drainage, tear meniscus dynamics, Krehbiel flow and lacrimal functional unit. Expert commentary: After decades, the topic of tear turnover assessment has been reintroduced. Recently, new techniques have been developed to propose less invasive, less time consuming and simpler methodologies for the assessment of tear dynamics that have the potential to be utilized in clinical practice.

  5. Frictional heterogeneities on carbonate-bearing normal faults: Insights from the Monte Maggio Fault, Italy

    NASA Astrophysics Data System (ADS)

    Carpenter, B. M.; Scuderi, M. M.; Collettini, C.; Marone, C.

    2014-12-01

    Observations of heterogeneous and complex fault slip are often attributed to the complexity of fault structure and/or spatial heterogeneity of fault frictional behavior. Such complex slip patterns have been observed for earthquakes on normal faults throughout central Italy, where many of the Mw 6 to 7 earthquakes in the Apennines nucleate at depths where the lithology is dominated by carbonate rocks. To explore the relationship between fault structure and heterogeneous frictional properties, we studied the exhumed Monte Maggio Fault, located in the northern Apennines. We collected intact specimens of the fault zone, including the principal slip surface and hanging wall cataclasite, and performed experiments at a normal stress of 10 MPa under saturated conditions. Experiments designed to reactivate slip between the cemented principal slip surface and cataclasite show a 3 MPa stress drop as the fault surface fails, then velocity-neutral frictional behavior and significant frictional healing. Overall, our results suggest that (1) earthquakes may readily nucleate in areas of the fault where the slip surface separates massive limestone and are likely to propagate in areas where fault gouge is in contact with the slip surface; (2) postseismic slip is more likely to occur in areas of the fault where gouge is present; and (3) high rates of frictional healing and low creep relaxation observed between solid fault surfaces could lead to significant aftershocks in areas of low stress drop.

  6. Deformation processes and weakening mechanisms within the frictional viscous transition zone of major crustal-scale faults: insights from the Great Glen Fault Zone, Scotland

    NASA Astrophysics Data System (ADS)

    Stewart, M.; Holdsworth, R. E.; Strachan, R. A.

    2000-05-01

    The Great Glen Fault Zone (GGFZ), Scotland, is a typical example of a crustal-scale, reactivated strike-slip fault within the continental crust. Analysis of intensely strained fault rocks from the core of the GGFZ near Fort William provides a unique insight into the nature of deformation associated with the main phase of (sinistral) movements along the fault zone. In this region, an exhumed sequence of complex mid-crustal deformation textures that developed in the region of the frictional-viscous transition (ca. 8-15 km depth) is preserved. Fault rock fabrics vary from mylonitic in quartzites to cataclastic in micaceous shear zones and feldspathic psammites. Protolith mineralogy exerted a strong control on the initial textural development and distribution of the fault rocks. At lower strains, crystal-plastic deformation occurred in quartz-dominated lithologies to produce mylonites simultaneously with widespread fracturing and cataclasis in feldspar- and mica-dominated rocks. At higher strains, shearing appears to increasingly localise into interconnected networks of cataclastic shear zones, many of which are strongly foliated. Textures indicative of fluid-assisted diffusive mass transfer mechanisms are widespread in such regions and suggest that a hydrous fluid-assisted, grainsize-controlled switch in deformation behaviour followed the brittle comminution of grains. The fault zone textural evolution implies that a strain-induced, fluid-assisted shallowing and narrowing of the frictional-viscous transition occurred with increasing strain. It is proposed that this led to an overall weakening of the fault zone and that equivalent processes may occur along many other long-lived, crustal-scale dislocations.

  7. Phospholipid transfer protein is present in human tear fluid.

    PubMed

    Jauhiainen, Matti; Setälä, Niko L; Ehnholm, Christian; Metso, Jari; Tervo, Timo M T; Eriksson, Ove; Holopainen, Juha M

    2005-06-07

    The human tear fluid film consists of a superficial lipid layer, an aqueous middle layer, and a hydrated mucin layer located next to the corneal epithelium. The superficial lipid layer protects the eye from drying and is composed of polar and neutral lipids provided by the meibomian glands. Excess accumulation of lipids in the tear film may lead to drying of the corneal epithelium. In the circulation, phospholipid transfer protein (PLTP) and cholesteryl ester transfer protein (CETP) mediate lipid transfers. To gain insight into the formation of tear film, we investigated whether PLTP and CETP are present in human tear fluid. Tear fluid samples were collected with microcapillaries. The presence of PLTP and CETP was studied in tear fluid by Western blotting, and the PLTP concentration was determined by ELISA. The activities of the enzymes were determined by specific lipid transfer assays. Size-exclusion and heparin-affinity chromatography assessed the molecular form of PLTP. PLTP is present in tear fluid, whereas CETP is not. Quantitative assessment of PLTP by ELISA indicated that the PLTP concentration in tear fluid, 10.9 +/- 2.4 microg/mL, is about 2-fold higher than that in human plasma. PLTP-facilitated phospholipid transfer activity in tears, 15.1 +/- 1.8 micromol mL(-)(1) h(-)(1), was also significantly higher than that measured in plasma. Inactivation of PLTP by heat treatment (+58 degrees C, 60 min) or immunoinhibition abolished the phospholipid transfer activity in tear fluid. Size-exclusion chromatography of tear fluid indicated that PLTP eluted in a position corresponding to a size of 160-170 kDa. Tear fluid PLTP was quantitatively bound to Heparin-Sepharose and could be eluted as a single peak by 0.5 M NaCl. These data indicate that human tear fluid contains catalytically active PLTP protein, which resembles the active form of PLTP present in plasma. The results suggest that PLTP may play a role in the formation of the tear film by supporting phospholipid

  8. On tear film breakup (TBU): dynamics and imaging.

    PubMed

    Braun, Richard J; Driscoll, Tobin A; Begley, Carolyn G; King-Smith, P Ewen; Siddique, Javed I

    2018-06-13

    We report the results of some recent experiments to visualize tear film dynamics. We then study a mathematical model for tear film thinning and tear film breakup (TBU), a term from the ocular surface literature. The thinning is driven by an imposed tear film thinning rate which is input from in vivo measurements. Solutes representing osmolarity and fluorescein are included in the model. Osmolarity causes osmosis from the model ocular surface, and the fluorescein is used to compute the intensity corresponding closely to in vivo observations. The imposed thinning can be either one-dimensional or axisymmetric, leading to streaks or spots of TBU, respectively. For a spatially-uniform (flat) film, osmosis would cease thinning and balance mass lost due to evaporation; for these space-dependent evaporation profiles TBU does occur because osmolarity diffuses out of the TBU into the surrounding tear film, in agreement with previous results. The intensity pattern predicted based on the fluorescein concentration is compared with the computed thickness profiles; this comparison is important for interpreting in vivo observations. The non-dimensionalization introduced leads to insight about the relative importance of the competing processes; it leads to a classification of large vs small TBU regions in which different physical effects are dominant. Many regions of TBU may be considered small, revealing that the flow inside the film has an appreciable influence on fluorescence imaging of the tear film.

  9. Mass spectrometric identification of phospholipids in human tears and tear lipocalin.

    PubMed

    Dean, Austin W; Glasgow, Ben J

    2012-04-02

    The purpose of this article was to identify by mass spectrometry phosphocholine lipids in stimulated human tears and determine the molecules bound to tear lipocalin or other proteins. Tear proteins were separated isocratically from pooled stimulated human tears by gel filtration fast performance liquid chromatography. Separation of tear lipocalin was confirmed by SDS tricine gradient PAGE. Protein fractions were extracted with chloroform/methanol and analyzed with electrospray ionization MS/MS triple quadrupole mass spectrometry in precursor ion scan mode for select leaving groups. For quantification, integrated ion counts were derived from standard curves of authentic compounds of phosphatidylcholine (PC) and phosphatidylserine. Linear approximation was possible from integration of the mass spectrometrically obtained ion peaks at 760 Da for the PC standard. Tears contained 194 ng/mL of the major intact PC (34:2), m/z 758.6. Ten other monoisotopic phosphocholines were found in tears. A peak at 703.3 Da was assigned as a sphingomyelin. Four lysophosphatidylcholines (m/z 490-540) accounted for about 80% of the total integrated ion count. The [M+H](+) compound, m/z 496.3, accounted for 60% of the signal intensity. Only the tear lipocalin-bearing fractions showed phosphocholines (104 ng/mL). Although the intact phospholipids bound to tear lipocalin corresponded precisely in mass and relative signal intensity to that found in tears, we did not identify phosphocholines between m/z 490 and 540 in any of the gel-filtration fractions. Phospholipids, predominantly lysophospholipids, are present in tears. The higher mass intact PCs in tears are native ligands of tear lipocalin.

  10. Coupling Osmolarity Dynamics within Human Tear Film on an Eye-Shaped Domain

    NASA Astrophysics Data System (ADS)

    Li, Longfei; Braun, R. J.; Driscoll, T. A.; Henshaw, W. D.; Banks, J. W.; King-Smith, P. E.

    2013-11-01

    The concentration of ions in the tear film (osmolarity) is a key variable in understanding dry eye symptoms and disease. We derived a mathematical model that couples osmolarity (treated as a single solute) and fluid dynamics within the tear film on a 2D eye-shaped domain. The model concerns the physical effects of evaporation, surface tension, viscosity, ocular surface wettability, osmolarity, osmosis and tear fluid supply and drainage. We solved the governing system of coupled nonlinear PDEs using the Overture computational framework developed at LLNL, together with a new hybrid time stepping scheme (using variable step BDF and RKC) that was added to the framework. Results of our numerical simulations show good agreement with existing 1D models (for both tear film and osmolarity dynamics) and provide new insight about the osmolarity distribution over the ocular surface during the interblink.

  11. Mass Spectrometric Identification of Phospholipids in Human Tears and Tear Lipocalin

    PubMed Central

    Dean, Austin W.; Glasgow, Ben J.

    2012-01-01

    Purpose. The purpose of this article was to identify by mass spectrometry phosphocholine lipids in stimulated human tears and determine the molecules bound to tear lipocalin or other proteins. Methods. Tear proteins were separated isocratically from pooled stimulated human tears by gel filtration fast performance liquid chromatography. Separation of tear lipocalin was confirmed by SDS tricine gradient PAGE. Protein fractions were extracted with chloroform/methanol and analyzed with electrospray ionization MS/MS triple quadrupole mass spectrometry in precursor ion scan mode for select leaving groups. For quantification, integrated ion counts were derived from standard curves of authentic compounds of phosphatidylcholine (PC) and phosphatidylserine. Results. Linear approximation was possible from integration of the mass spectrometrically obtained ion peaks at 760 Da for the PC standard. Tears contained 194 ng/mL of the major intact PC (34:2), m/z 758.6. Ten other monoisotopic phosphocholines were found in tears. A peak at 703.3 Da was assigned as a sphingomyelin. Four lysophosphatidylcholines (m/z 490–540) accounted for about 80% of the total integrated ion count. The [M+H]+ compound, m/z 496.3, accounted for 60% of the signal intensity. Only the tear lipocalin–bearing fractions showed phosphocholines (104 ng/mL). Although the intact phospholipids bound to tear lipocalin corresponded precisely in mass and relative signal intensity to that found in tears, we did not identify phosphocholines between m/z 490 and 540 in any of the gel-filtration fractions. Conclusions. Phospholipids, predominantly lysophospholipids, are present in tears. The higher mass intact PCs in tears are native ligands of tear lipocalin. PMID:22395887

  12. Fault reactivation: The Picuris-Pecos fault system of north-central New Mexico

    NASA Astrophysics Data System (ADS)

    McDonald, David Wilson

    The PPFS is a N-trending fault system extending over 80 km in the Sangre de Cristo Mountains of northern New Mexico. Precambrian basement rocks are offset 37 km in a right-lateral sense; however, this offset includes dextral strike-slip (Precambrian), mostly normal dip-slip (Pennsylvanian), mostly reverse dip-slip (Early Laramide), limited strike-slip (Late Laramide) and mostly normal dip-slip (Cenozoic). The PPFS is broken into at least 3 segments by the NE-trending Embudo fault and by several Laramide age NW-trending tear faults. These segments are (from N to S): the Taos, the Picuris, and the Pecos segments. On the east side of the Picuris segment in the Picuris Mountains, the Oligocene-Miocene age Miranda graben developed and represents a complex extension zone south of the Embudo fault. Regional analysis of remotely sensed data and geologic maps indicate that lineaments subparallel to the trace of the PPFS are longer and less frequent than lineaments that trend orthogonal to the PPFS. Significant cross cutting faults and subtle changes in fault trends in each segment are clear in the lineament data. Detailed mapping in the eastern Picuris Mountains showed that the favorably oriented Picuris segment was not reactivated in the Tertiary development of the Rio Grande rift. Segmentation of the PPFS and post-Laramide annealing of the Picuris segment are interpreted to have resulted in the development of the subparallel La Serna fault. The Picuris segment of the PPFS is offset by several E-ESE trending faults. These faults are Late Cenozoic in age and interpreted to be related to the uplift of the Picuris Mountains and the continuing sinistral motion on the Embudo fault. Differential subsidence within the Miranda graben caused the development of several synthetic and orthogonal faults between the bounding La Serna and Miranda faults. Analysis of over 10,000 outcrop scale brittle structures reveals a strong correlation between faults and fracture systems. The dominant

  13. A comparison of basal and eye-flush tears for the analysis of cat tear proteins.

    PubMed

    Petznick, Andrea; Evans, Margaret D M; Madigan, Michele C; Markoulli, Maria; Garrett, Qian; Sweeney, Deborah F

    2011-02-01

    To identify a rapid and effective tear collection method providing sufficient tear volume and total protein content (TPC) for analysis of individual proteins in cats. Domestic adult short-haired cats (12-37 months; 2.7-6.6 kg) were used in the study. Basal tears without stimulation and eye-flush tears after instillation of saline (10 μl) were collected using microcapillary tubes from animal eyes either unwounded control or wounded with 9-mm central epithelial debridement giving four groups with n = 3. Tear comparisons were based on total time and rate for tear collection, TPC using micro bicinchoninic acid (BCA), tear immunoglobulin A (IgA), total matrix-metalloproteinase (MMP)-9 concentration using sandwich enzyme-linked immunosorbent assay (ELISA) and MMP-9 activity. Eye-flush tears were collected significantly faster than basal tears in wounded eyes with higher rates for tear collection in unwounded control and wounded eyes. TPC was significantly lower in eye-flush tears compared to basal tears. The relative proportion of tear IgA normalized to TPC (% IgA of TPC) was not significantly different between basal and eye-flush tears. In unwounded control eyes, MMP-9 was slightly higher in eye-flush than in basal tears; activity of MMP-9 in both tear types was similar. In wounded eyes, eye-flush tears showed highest MMP-9 levels and activity on Day 1, which subsequently decreased to Day 7. MMP-9 activity in basal tears from wounded eyes did not display changes in expression. Eye-flush tears can be collected rapidly providing sufficient tear volume and TPC. This study also indicates that eye-flush tears may be more suitable than basal tears for the analysis of MMPs following corneal wounding. © 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.

  14. Behavior of sphingomyelin and ceramide in a tear film lipid layer model.

    PubMed

    Olżyńska, Agnieszka; Cwiklik, Lukasz

    2017-03-01

    Tear film lipid layer is a complex lipid mixture forming the outermost interface between eye and environment. Its key characteristics, such as surface tension and structural stability, are governed by the presence of polar lipids. The origin of these lipids and exact composition of the mixture are still elusive. We focus on two minor polar lipid components of the tear film lipid later: sphingomyelin and ceramide. By employing coarse grain molecular dynamics in silico simulations accompanied by Langmuir balance experiments we provide molecular-level insight into behavior of these two lipids in a tear film lipid layer model. Sphingomyelin headgroups are significantly exposed at the water-lipids boundary while ceramide molecules are incorporated between other lipids frequently interacting with nonpolar lipids. Even though these two lipids increase surface tension of the film, their molecular-level behavior suggests that they have a stabilizing effect on the tear film lipid layer. Copyright © 2016 Elsevier GmbH. All rights reserved.

  15. Blocked Tear Duct

    MedlinePlus

    ... of the nose (lacrimal sac). From there tears travel down a duct (the nasolacrimal duct) draining into your nose. Once in the nose, tears are reabsorbed. A blockage can occur at any point in the tear drainage system, from the puncta ...

  16. Computed tear film and osmolarity dynamics on an eye-shaped domain

    PubMed Central

    Li, Longfei; Braun, Richard J.; Driscoll, Tobin A.; Henshaw, William D.; Banks, Jeffrey W.; King-Smith, P. Ewen

    2016-01-01

    The concentration of ions, or osmolarity, in the tear film is a key variable in understanding dry eye symptoms and disease. In this manuscript, we derive a mathematical model that couples osmolarity (treated as a single solute) and fluid dynamics within the tear film on a 2D eye-shaped domain. The model includes the physical effects of evaporation, surface tension, viscosity, ocular surface wettability, osmolarity, osmosis and tear fluid supply and drainage. The governing system of coupled non-linear partial differential equations is solved using the Overture computational framework, together with a hybrid time-stepping scheme, using a variable step backward differentiation formula and a Runge–Kutta–Chebyshev method that were added to the framework. The results of our numerical simulations provide new insight into the osmolarity distribution over the ocular surface during the interblink. PMID:25883248

  17. Robustness to Faults Promotes Evolvability: Insights from Evolving Digital Circuits

    PubMed Central

    Nolfi, Stefano

    2016-01-01

    We demonstrate how the need to cope with operational faults enables evolving circuits to find more fit solutions. The analysis of the results obtained in different experimental conditions indicates that, in absence of faults, evolution tends to select circuits that are small and have low phenotypic variability and evolvability. The need to face operation faults, instead, drives evolution toward the selection of larger circuits that are truly robust with respect to genetic variations and that have a greater level of phenotypic variability and evolvability. Overall our results indicate that the need to cope with operation faults leads to the selection of circuits that have a greater probability to generate better circuits as a result of genetic variation with respect to a control condition in which circuits are not subjected to faults. PMID:27409589

  18. Insights into the Fault Geometry and Rupture History of the 2016 MW 7.8 Kaikoura, New Zealand, Earthquake

    NASA Astrophysics Data System (ADS)

    Adams, M.; Ji, C.

    2017-12-01

    The November 14th 2016 MW 7.8 Kaikoura, New Zealand earthquake occurred along the east coast of the northern part of the South Island. The local tectonic setting is complicated. The central South Island is dominated by oblique continental convergence, whereas the southern part of this island experiences eastward subduction of the Australian plate. Available information (e.g., Hamling et al., 2017; Bradley et al., 2017) indicate that this earthquake involved multiple fault segments of the Marlborough fault system (MFS) as the rupture propagated northwards for more than 150 km. Additional slip might also occur on the subduction interface of the Pacific plate under the Australian plate, beneath the MFS. However, the exact number of involved fault segments as well as the temporal co-seismic rupture sequence has not been fully determined with geodetic and geological observations. Knowledge of the kinematics of complex fault interactions has important implications for our understanding of global seismic hazards, particularly to relatively unmodeled multisegment ruptures. Understanding the Kaikoura earthquake will provide insight into how one incorporates multi-fault ruptures in seismic-hazard models. We propose to apply a multiple double-couple inversion to determine the fault geometry and spatiotemporal rupture history using teleseismic and strong motion waveforms, before constraining the detailed slip history using both seismic and geodetic data. The Kaikoura earthquake will be approximated as the summation of multiple subevents—each represented as a double-couple point source, characterized by i) fault geometry (strike, dip and rake), ii) seismic moment, iii) centroid time, iv) half-duration and v) location (latitude, longitude and depth), a total of nine variables. We progressively increase the number of point sources until the additional source cannot produce significant improvement to the observations. Our preliminary results using only teleseismic data indicate

  19. Extensive characterization of human tear fluid collected using different techniques unravels the presence of novel lipid amphiphiles1[S

    PubMed Central

    Lam, Sin Man; Tong, Louis; Duan, Xinrui; Petznick, Andrea; Wenk, Markus R.; Shui, Guanghou

    2014-01-01

    The tear film covers the anterior eye and the precise balance of its various constituting components is critical for maintaining ocular health. The composition of the tear film amphiphilic lipid sublayer, in particular, has largely remained a matter of contention due to the limiting concentrations of these lipid amphiphiles in tears that render their detection and accurate quantitation tedious. Using systematic and sensitive lipidomic approaches, we validated different tear collection techniques and report the most comprehensive human tear lipidome to date; comprising more than 600 lipid species from 17 major lipid classes. Our study confers novel insights to the compositional details of the existent tear film model, in particular the disputable amphiphilic lipid sublayer constituents, by demonstrating the presence of cholesteryl sulfate, O-acyl-ω-hydroxyfatty acids, and various sphingolipids and phospholipids in tears. The discovery and quantitation of the relative abundance of various tear lipid amphiphiles reported herein are expected to have a profound impact on the current understanding of the existent human tear film model. PMID:24287120

  20. Physical and Transport Property Variations Within Carbonate-Bearing Fault Zones: Insights From the Monte Maggio Fault (Central Italy)

    NASA Astrophysics Data System (ADS)

    Trippetta, F.; Carpenter, B. M.; Mollo, S.; Scuderi, M. M.; Scarlato, P.; Collettini, C.

    2017-11-01

    The physical characterization of carbonate-bearing normal faults is fundamental for resource development and seismic hazard. Here we report laboratory measurements of density, porosity, Vp, Vs, elastic moduli, and permeability for a range of effective confining pressures (0.1-100 MPa), conducted on samples representing different structural domains of a carbonate-bearing fault. We find a reduction in porosity from the fault breccia (11.7% total and 6.2% connected) to the main fault plane (9% total and 3.5% connected), with both domains showing higher porosity compared to the protolith (6.8% total and 1.1% connected). With increasing confining pressure, P wave velocity evolves from 4.5 to 5.9 km/s in the fault breccia, is constant at 5.9 km/s approaching the fault plane and is low (4.9 km/s) in clay-rich fault domains. We find that while the fault breccia shows pressure sensitive behavior (a reduction in permeability from 2 × 10-16 to 2 × 10-17 m2), the cemented cataclasite close to the fault plane is characterized by pressure-independent behavior (permeability 4 × 10-17 m2). Our results indicate that the deformation processes occurring within the different fault structural domains influence the physical and transport properties of the fault zone. In situ Vp profiles match well the laboratory measurements demonstrating that laboratory data are valuable for implications at larger scale. Combining the experimental values of elastic moduli and frictional properties it results that at shallow crustal levels, M ≤ 1 earthquakes are less favored, in agreement with earthquake-depth distribution during the L'Aquila 2009 seismic sequence that occurred on carbonates.

  1. Structural analysis using thrust-fault hanging-wall sequence diagrams: Ogden duplex, Wasatch Range, Utah

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schirmer, T.W.

    1988-05-01

    Detailed mapping and cross-section traverses provide the control for structural analysis and geometric modeling of the Ogden duplex, a complex thrust system exposed in the Wasatch Mountains, east of Ogden, Utah. The structures consist of east-dipping folded thrust faults, basement-cored horses, lateral ramps and folds, and tear faults. The sequence of thrusting determined by means of lateral overlap of horses, thrust-splay relationships, and a top-to-bottom piggyback development is Willard thrust, Ogden thrust, Weber thrust, and Taylor thrust. Major decollement zones occur in the Cambrian shales and limestones. The Tintic Quartzite is the marker for determining gross geometries of horses. Thismore » exposed duplex serves as a good model to illustrate the method of constructing a hanging-wall sequence diagram - a series of longitudinal cross sections that move forward in time and space, and show how a thrust system formed as it moved updip over various footwall ramps. A hanging wall sequence diagram also shows the complex lateral variations in a thrust system and helps to locate lateral ramps, lateral folds, tear faults, and other features not shown on dip-oriented cross sections. 8 figures.« less

  2. Divalent cations in tears, and their influence on tear film stability in humans and rabbits.

    PubMed

    Wei, Xiaojia Eric; Markoulli, Maria; Millar, Thomas J; Willcox, Mark D P; Zhao, Zhenjun

    2012-06-05

    Reduced tear film stability is reported to contribute to dry eye. Rabbits are known to have a more stable tear film than humans. Thus, we sought to examine the tears of rabbits and humans for metal cations, and to test how they influence tear film stability. Tears were collected from 10 healthy humans and 6 rabbits. Tear osmolality was measured by vapor pressure osmometer, and metals analyzed using inductively coupled plasma (ICP) mass spectrometry or ICP atomic emission spectroscopy. The influence of divalent cations on tears was analyzed by measuring surface tension using the Langmuir trough in vitro, using different concentrations of cations in the subphase, and grading the tear break-up in rabbits in vivo after instillation of chelating agents. Rabbit tears had a higher osmolality compared to humans. Major metals did not differ between species; however, rabbits had higher levels of Mg(2+) (1.13 vs. 0.39 mM) and Ca(2+) (0.75 vs. 0.36 mM). In rabbit tears in vitro, diminishing divalent cations resulted in a decrease in the maximum surface pressure from 37 to 30 mN/m. In vivo, an increase in the amount of tear film that was broken-up was found. In contrast, when changing divalent cation concentrations in human tears, the maximum surface pressure remained at 26 mN/m. The normal osmolality of rabbit tears is significantly higher than that in humans. While divalent cations had little influence on human tears, they appear to have an important role in maintaining tear film stability in rabbits.

  3. Radial tears associated with cleavage tears of the medial meniscus in athletes.

    PubMed

    Kidron, Amos; Thein, Rafael

    2002-03-01

    To evaluate the significance of a small radial tear in the root of the posterior horn of the medial meniscus in an otherwise normal-looking meniscus in individuals who play vigorous sports. Retrospective review. Arthroscopy was performed in 1,270 patients; 11 patients (0.86%) had a small radial tear in the root of the medial meniscus. Trimming of the tear revealed a large horizontal cleavage tear of the posterior horn and body of the meniscus. The average age of the affected patients was 29.6 years (range, 21 to 45 years), and all were active in sports. Magnetic resonance imaging was of dubious diagnostic value. Three patients had undergone previous arthroscopy at which time the small radial root tear had been noted but was not thought to warrant treatment. All 11 patients returned to their former levels of activity after adequate surgery. When a radial root tear in the medial meniscus is found in an athletic patient, the edges of the tear should be trimmed, the root of the medial meniscus examined, and any additional torn cartilage resected.

  4. Contrasting fault fluids along high-angle faults: a case study from Southern Apennines (Italy)

    NASA Astrophysics Data System (ADS)

    Sinisi, Rosa; Petrullo, Angela Vita; Agosta, Fabrizio; Paternoster, Michele; Belviso, Claudia; Grassa, Fausto

    2016-10-01

    This work focuses on two fault-controlled deposits, the Atella and Rapolla travertines, which are associated with high-angle extensional faults of the Bradano Trough, southern Apennines (Italy). The Atella travertine is along a NW-SE striking, deep-seated extensional fault, already described in literature, which crosscuts both Apulian carbonates and the overlying foredeep basin infill. The Rapolla travertine is on top of a NE-SW striking, shallow-seated fault, here described for the first time, which is interpreted as a tear fault associated with a shallow thrust displacing only the foredeep basin infill. The results of structural, sedimentological, mineralogical, and C and O isotope analyses are here reported and discussed to assess the provenance of mineralizing fluids, and to evaluate the control exerted by the aforementioned extensional faults on deep, mantle-derived and shallow, meteoric fluids. Sedimentological analysis is consistent with five lithofacies in the studied travertines, which likely formed in a typical lacustrine depositional environment. Mineralogical analysis show that travertines mainly consist of calcite, and minor quartz, feldspar and clay minerals, indicative of a terrigenous supply during travertine precipitation. The isotope signature of the two studied travertines shows different provenance for the mineralizing fluids. At the Atella site, the δ13CPDB values range between + 5.2 and + 5.7‰ and the δ18OPDB values between - 9.0 and - 7.3‰, which are consistent with a mantle-derived CO2 component in the fluid. In contrast, at the Rapolla site the δ13CPDB values vary from - 2.7 to + 1.5‰ and the δ18OPDB values from - 6.8 to - 5.4‰, suggesting a mixed CO2 source with both biogenic-derived and mantle-derived fluids. The results of structural analyses conducted along the footwall damage zone of the fault exposed at the Rapolla site, show that the whole damage zone, in which fractures and joints likely channeled the mixed fluids, acted

  5. Symptomatic rotator cuff tears show higher radioisotope uptake on bone scintigraphy compared with asymptomatic tears.

    PubMed

    Koike, Yoichi; Sano, Hirotaka; Kita, Atushi; Itoi, Eiji

    2013-09-01

    Some patients with rotator cuff tears complain of pain, whereas others are asymptomatic. Previous studies have pointed out the presence of active bone metabolism in the painful shoulder, identified with increased radioisotope uptake during bone scintigraphy. Shoulders with symptomatic rotator cuff tears will demonstrate higher radioisotope uptake than shoulders with asymptomatic tears with bone scintigraphy, reflecting active bone metabolism in symptomatic tears. Cross-sectional study; Level of evidence, 3. The study consisted of 3 groups: patients with symptomatic tears (symptomatic group), patients with asymptomatic tears (asymptomatic group), and controls (no tear group). The symptomatic group consisted of 28 shoulders from 28 patients with symptomatic rotator cuff tears (pain score ≤4 on the University of California, Los Angeles [UCLA] shoulder evaluation form) who underwent bone scintigraphy followed by rotator cuff repair. Of 70 volunteers who had previously undergone bone scintigraphy for diseases unrelated to their shoulder, 34 were selected for the asymptomatic group (pain score ≥8 on the UCLA shoulder form), and 32 were selected for the no tear group. The mean radioisotope uptake in the symptomatic group was significantly higher than that in the asymptomatic group (P = .02) and the no tear group (P = .02). Ten of 28 shoulders (36%) in the symptomatic group showed increased radioisotope uptake exceeding 2 standard deviations from the mean of the no tear group. This percentage was significantly higher when compared with the asymptomatic group (0%) (P < .01). Shoulders with a symptomatic rotator cuff tear showed higher radioisotope uptake on bone scintigraphy than those with an asymptomatic tear. The radioisotope uptake in shoulders with an asymptomatic tear was comparable with that in shoulders without a tear. Positive radioisotope uptake may be associated with pain in a subgroup of patients with rotator cuff tears.

  6. Gene expression profiles of changes underlying different-sized human rotator cuff tendon tears.

    PubMed

    Chaudhury, Salma; Xia, Zhidao; Thakkar, Dipti; Hakimi, Osnat; Carr, Andrew J

    2016-10-01

    Progressive cellular and extracellular matrix (ECM) changes related to age and disease severity have been demonstrated in rotator cuff tendon tears. Larger rotator cuff tears demonstrate structural abnormalities that potentially adversely influence healing potential. This study aimed to gain greater insight into the relationship of pathologic changes to tear size by analyzing gene expression profiles from normal rotator cuff tendons, small rotator cuff tears, and large rotator cuff tears. We analyzed gene expression profiles of 28 human rotator cuff tendons using microarrays representing the entire genome; 11 large and 5 small torn rotator cuff tendon specimens were obtained intraoperatively from tear edges, which we compared with 12 age-matched normal controls. We performed real-time polymerase chain reaction and immunohistochemistry for validation. Torn rotator cuff tendons demonstrated upregulation of a number of key genes, such as matrix metalloproteinase 3, 10, 12, 13, 15, 21, and 25; a disintegrin and metalloproteinase (ADAM) 12, 15, and 22; and aggrecan. Amyloid was downregulated in all tears. Small tears displayed upregulation of bone morphogenetic protein 5. Chemokines and cytokines that may play a role in chemotaxis were altered; interleukins 3, 10, 13, and 15 were upregulated in tears, whereas interleukins 1, 8, 11, 18, and 27 were downregulated. The gene expression profiles of normal controls and small and large rotator cuff tear groups differ significantly. Extracellular matrix remodeling genes were found to contribute to rotator cuff tear pathogenesis. Rotator cuff tears displayed upregulation of a number of matrix metalloproteinase (3, 10, 12, 13, 15, 21, and 25), a disintegrin and metalloproteinase (ADAM 12, 15, and 22) genes, and downregulation of some interleukins (1, 8, and 27), which play important roles in chemotaxis. These gene products may potentially have a role as biomarkers of failure of healing or therapeutic targets to improve tendon

  7. Risk Factors for Tear Progression in Symptomatic Rotator Cuff Tears: A Prospective Study of 174 Shoulders.

    PubMed

    Yamamoto, Nobuyuki; Mineta, Mitsuyoshi; Kawakami, Jun; Sano, Hirotaka; Itoi, Eiji

    2017-09-01

    The risk factors for tear progression in symptomatic rotator cuff tears have not been clarified yet. It is important for orthopaedic surgeons to know the natural course of tear progression when nonoperative management is to be chosen. Tears in younger patients, high-activity patients, or heavy laborers would progress in size more than those in older patients, low-activity patients, or light laborers. Case-control study; Level of evidence, 3. Two hundred twenty-five consecutive patients with symptomatic rotator cuff tears visited our institute between 2009 and 2015. Of these, 174 shoulders of 171 patients (mean age, 66.9 years) who underwent at least 2 magnetic resonance imaging (MRI) examinations were prospectively enrolled. The mean follow-up was 19 months. Tear progression was defined as positive when the tear size increased by ≥2 mm. The demographic factors that were analyzed by multivariate analysis included age, sex, hand dominance, smoking, alcohol drinking, hypercholesterolemia, sports participation, job type, tear size, and tear type (full or partial thickness). Of the 174 shoulders, 82 shoulders (47%) showed tear progression. The mean (±SD) tear length and width in the progression group on final MRI were 23.1 ± 12.5 mm and 17.3 ± 9.6 mm, respectively; the tear size progressed by a mean 5.8 ± 5.6 mm in length and 3.1 ± 5.2 mm in width. The mean propagation speed was 3.8 mm/y in length and 2.0 mm/y in width. The size of full-thickness tears significantly increased compared with that of articular-sided partial-thickness tears ( P = .0215). The size of medium tears significantly increased compared with that of other tears ( P < .0001). According to the logistic regression analysis, smoking was significantly correlated with tear progression ( P = .026). Subgroup analyses showed that male sex, hand dominance, and trauma were correlated with tear progression. Age, alcohol drinking, hypercholesterolemia, sports participation, and job type did not show any

  8. Hot pressing in conduit faults during lava dome extrusion: Insights from Mount St. Helens 2004-2008

    NASA Astrophysics Data System (ADS)

    Ryan, Amy G.; Friedlander, Elizabeth A.; Russell, James K.; Heap, Michael J.; Kennedy, Lori A.

    2018-01-01

    Rhyodacitic volcanoes such as Mount St. Helens (MSH), Soufrière Hills, Mount Unzen and Mount Pelée erupt spines mantled by layers of magma-derived cataclasite and fault gouge. MSH produced seven lava spines from 2004-2008 composed of low-porosity, compositionally uniform, crystalline dacite. Dome extrusion was attended by continuous 'drumbeat' seismicity, derived from faulting along the conduit margin at 0.5-1 km depth, and evidenced by the enveloping gouge layers. We describe the properties of the gouge-derived fault rocks, including laboratory measurements of porosity and permeability. The gouge varies from unconsolidated powder to lithified low-porosity low-permeability fault rocks. We reconstruct the subsurface ascent of the MSH magma using published field observations and create a model that reconciles the diverse properties of the gouge with conditions in the conduit during ascent (i.e. velocity, temperature). We show lithification of the gouge to be driven by 'hot pressing' processes, wherein the combination of elevated temperature, confining pressure and dwell-time cause densification and solid-state sintering of the comminuted, crystal-rich (glass-poor) gouge. The degree of gouge lithification corresponds with residence time in the conduit such that well-lithified materials reflect extended times in the subsurface due to slower ascent rates. With this insight, we suggest that gouge competence can be used as a first-order estimate of lava ascent rates. Furthermore we posit gouge lithification, which reduces porosity and permeability, inhibits volcanic outgassing thereby increasing the potential for explosive events at spine-producing volcanoes.

  9. [Rotator cuff tear athropathy prevalence].

    PubMed

    Guerra-Soriano, F; Encalada-Díaz, M I; Ruiz-Suárez, M; Valero-González, F S

    2017-01-01

    Glenohumeral arthritis secondary to massive rotator cuff tear presents with a superior displacement and femoralization of the humeral head with coracoacromial arch acetabularization. The purpose of this study was to establish prevalence of rotator cuff tear artropathy (CTA) at our institution. Four hundred electronic records were reviewed from which we identified 136 patients with rotator cuff tears. A second group was composed with patients with massive cuff tears that were analized and staged by the Seebauer cuff tear arthropathy classification. Thirty four patients with massive rotator cuff tears were identified, 8 male and 26 female (age 60.1 ± 10.26 years). Massive rotator cuff tear prevalence was 25%. CTA prevalence found in the rotator cuff group was 19 and 76% in the massive cuff tears group. Patients were staged according to the classification with 32% in stage 1a, 11% 1b, 32% 2a and 0% 2b. CTA prevalence in patients with rotator cuff tears and massive cuff tears is higher than the one reported in American population. We consider that a revision of the Seebauer classification to be appropriate to determine its reliability.

  10. Antimicrobial Compounds in Tears

    PubMed Central

    McDermott, Alison M.

    2013-01-01

    The tear film coats the cornea and conjunctiva and serves several important functions. It provides lubrication, prevents drying of the ocular surface epithelia, helps provide a smooth surface for refracting light, supplies oxygen and is an important component of the innate defense system of the eye providing protection against a range of potential pathogens. This review describes both classic antimicrobial compounds found in tears such as lysozyme and some more recently identified such as members of the cationic antimicrobial peptide family and surfactant protein-D as well as potential new candidate molecules that may contribute to antimicrobial protection. As is readily evident from the literature review herein, tears, like all mucosal fluids, contain a plethora of molecules with known antimicrobial effects. That all of these are active in vivo is debatable as many are present in low concentrations, may be influenced by other tear components such as the ionic environment, and antimicrobial action may be only one of several activities ascribed to the molecule. However, there are many studies showing synergistic/additive interactions between several of the tear antimicrobials and it is highly likely that cooperativity between molecules is the primary way tears are able to afford significant antimicrobial protection to the ocular surface in vivo. In addition to effects on pathogen growth and survival some tear components prevent epithelial cell invasion and promote the epithelial expression of innate defense molecules. Given the protective role of tears a number of scenarios can be envisaged that may affect the amount and/or activity of tear antimicrobials and hence compromise tear immunity. Two such situations, dry eye disease and contact lens wear, are discussed here. PMID:23880529

  11. Truth without Tears: African American Women Deans Share Lessons in Leadership

    ERIC Educational Resources Information Center

    Hodges, Carolyn R.; Welch, Olga M.

    2018-01-01

    "Truth Without Tears" is a timely and insightful portrait of Black women leaders in American colleges and universities. Carolyn R. Hodges and Olga M. Welch are former deans who draw extensively on their experience as African American women to account for both the challenges and opportunities facing women of color in educational…

  12. Tear progression of symptomatic full-thickness and partial-thickness rotator cuff tears as measured by repeated MRI.

    PubMed

    Kim, Yang-Soo; Kim, Sung-Eun; Bae, Sung-Ho; Lee, Hyo-Jin; Jee, Won-Hee; Park, Chang Kyun

    2017-07-01

    The purpose of this study was to analyse the natural course of symptomatic full-thickness and partial-thickness rotator cuff tears treated non-operatively and to identify risk factors affecting tear enlargement. One hundred and twenty-two patients who received non-surgical treatment for a partial- or full-thickness supraspinatus tear were included in this study. All rotator cuff tears were diagnosed with magnetic resonance imaging (MRI), and the same modality was used for follow-up studies. Follow-up MRI was performed after at least a 6-month interval. We evaluated the correlation between tear enlargement and follow-up duration. Eleven risk factors were analysed by both univariate and multivariate analyses to identify factors that affect enlargement of rotator cuff tears. The mean follow-up period was 24.4 ± 19.5 months. Out of 122 patients, 34 (27.9%) patients had an initial full-thickness tear and 88 (72.1%) patients had a partial-thickness tear. Considering all patients together, tear size increased in 51/122 (41.8%) patients, was unchanged in 65/122 (53.3%) patients, and decreased in 6/122 (4.9%) patients. Tear size increased for 28/34 (82.4%) patients with full-thickness tears and 23/88 (26.1%) patients with partial-thickness tears. From the two groups which were followed over 12 months, a higher rate of enlargement was observed in full-thickness tears than in partial-thickness tears (6-12 months, n.s.; 12-24 months, P = 0.002; over 24 months, P < 0.001). Logistic regression revealed that having a full-thickness tear was the most reliable risk factor for tear progression (P < 0.001). This study found that 28/34 (82.4%) of symptomatic full-thickness rotator cuff tears and 23/88 (26.1%) of symptomatic partial-thickness tears increased in size over a follow-up period of 6-100 months. Full-thickness tears showed a higher rate of enlargement than partial-thickness tears regardless of the follow-up duration. Univariate and multivariate analyses

  13. Human tears contain a chemosignal.

    PubMed

    Gelstein, Shani; Yeshurun, Yaara; Rozenkrantz, Liron; Shushan, Sagit; Frumin, Idan; Roth, Yehudah; Sobel, Noam

    2011-01-14

    Emotional tearing is a poorly understood behavior that is considered uniquely human. In mice, tears serve as a chemosignal. We therefore hypothesized that human tears may similarly serve a chemosignaling function. We found that merely sniffing negative-emotion-related odorless tears obtained from women donors induced reductions in sexual appeal attributed by men to pictures of women's faces. Moreover, after sniffing such tears, men experienced reduced self-rated sexual arousal, reduced physiological measures of arousal, and reduced levels of testosterone. Finally, functional magnetic resonance imaging revealed that sniffing women's tears selectively reduced activity in brain substrates of sexual arousal in men.

  14. Subscapularis tendon tears

    PubMed Central

    Lenart, Brett A.; Ticker, Jonathan B.

    2017-01-01

    Tears of the subscapularis tendon have been under-recognised until recently. Therefore, a high index of suspicion is essential for diagnosis. A directed physical examination, including the lift-off, belly-press and increased passive external rotation can help identify tears of the subscapularis. All planes on MR imaging should be carefully evaluated to identify tears of the subscapularis, retraction, atrophy and biceps pathology. Due to the tendency of the tendon to retract medially, acute and traumatic full-thickness tears should be repaired. Chronic tears without significant degeneration should be considered for repair if no contraindication exists. Arthroscopic repair can be performed using a 30-degree arthroscope and a laterally-based single row repair; one anchor for full thickness tears ⩽ 50% of tendon length and two anchors for those ⩾ 50% of tendon length. Biceps pathology, which is invariably present, should be addressed by tenotomy or tenodesis. Timing of post-operative rehabilitation is dictated by the size of the repair and the security of the repair construct. The stages of rehabilitation typically involve a period of immobilisation followed by range of movement exercises, with a delay in active internal rotation (IR) and strengthening in IR. Cite this article: EFORT Open Rev 2017;2:484–495. DOI: 10.1302/2058-5241.2.170015 PMID:29387471

  15. Antimicrobial compounds in tears.

    PubMed

    McDermott, Alison M

    2013-12-01

    The tear film coats the cornea and conjunctiva and serves several important functions. It provides lubrication, prevents drying of the ocular surface epithelia, helps provide a smooth surface for refracting light, supplies oxygen and is an important component of the innate defense system of the eye providing protection against a range of potential pathogens. This review describes both classic antimicrobial compounds found in tears such as lysozyme and some more recently identified such as members of the cationic antimicrobial peptide family and surfactant protein-D as well as potential new candidate molecules that may contribute to antimicrobial protection. As is readily evident from the literature review herein, tears, like all mucosal fluids, contain a plethora of molecules with known antimicrobial effects. That all of these are active in vivo is debatable as many are present in low concentrations, may be influenced by other tear components such as the ionic environment, and antimicrobial action may be only one of several activities ascribed to the molecule. However, there are many studies showing synergistic/additive interactions between several of the tear antimicrobials and it is highly likely that cooperativity between molecules is the primary way tears are able to afford significant antimicrobial protection to the ocular surface in vivo. In addition to effects on pathogen growth and survival some tear components prevent epithelial cell invasion and promote the epithelial expression of innate defense molecules. Given the protective role of tears a number of scenarios can be envisaged that may affect the amount and/or activity of tear antimicrobials and hence compromise tear immunity. Two such situations, dry eye disease and contact lens wear, are discussed here. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Structural styles of the Guess Creek fault block beneath the Great Smoky thrust sheet, Blount County, Tennessee

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carter, M.W.; Davidson, G.L.; Heller, J.A.

    1993-03-01

    A road cut along US 321 N, approximately 1 km NW of Walland, TN, exposes a previously unexposed complexly deformed section of Middle Ordovician clastic wedge [Chickamauga Group, Sevier Shale] sedimentary rocks. It provides an excellent opportunity to analyze both the lithologic assemblages and complex folding and faulting beneath the Great Smoky thrust sheet. Arkosic quartzite of the Lower Cambrian Cochran Conglomerate [Chilhowee Group], has been thrust over weaker Sevier Shale in the hanging wall of the Guess Creek fault. Regionally, the Great Smoky fault separates metamorphosed Precambrian to Lower Cambrian clastic shelf, slope, and rift facies rocks of themore » western Blue Ridge from Cambro-Ordovician carbonate shelf and orogenic wedge deposits of the foreland fold and thrust belt. West of the Great Smoky fault, the Guess Creek fault has been interpreted to floor duplexed Cambro-Ordovician rocks exposed in windows beneath the Great Smoky thrust sheet in the vicinity of the Great Smoky Mountains National Park. The Sevier Shale here consists of variably cleaved shale, siltstone, sandstone, and conglomerate. It exhibits a variety of fold styles throughout the exposure, ranging from predominantly noncylindrical tight folds to broad, open structures. A weak axial-planar pencil cleavage is developed in the Middle Ordovician shale and siltstone, along with a secondary cleavage that transects the axial surfaces of the folds. Minor thrust faults within the Sevier Shale appear to have formed by propagation through tightened fold hinges or bedding-parallel slip. The fold pattern observed in the roadcut appears to be partly the result of movement along a tear fault that broke both the hanging wall and footwall of the Great Smoky thrust sheet after emplacement. Slickenline orientations along minor thrust surfaces in the Cochran Conglomerate indicate eastward-directed, oblique-slip movement of the tear fault.« less

  17. A Controlled Study on the Correlation between Tear Film Volume and Tear Film Stability in Diabetic Patients.

    PubMed

    Eissa, Iman M; Khalil, Noha M; El-Gendy, Heba A

    2016-01-01

    Purpose. To assess the tear film quantity and correlate it with the quality and stability of the tear film in diabetics and compare them to age matched controls. Introduction. Diabetes affects tear film parameters in multiple ways. Poor metabolic control and neuropathy are postulated factors. To further understand how diabetes affects tear film parameters this study was conducted. Subjects and Methods. Tear meniscus height was measured by anterior segment OCT, along with tear thinning time, a subtype of noninvasive tear break-up time, and blinking rate per minute which were all recorded for 22 diabetic patients. Correlations between these tear film parameters were studied and then compared to 16 age matched controls. Results. A statistically significant difference was found in blinking rate between the diabetic and the control group (P = 0.002), with higher blinking rate among diabetics. All tear film parameters were negatively correlated with duration of diabetes. A positive correlation was found between tear film volume and stability. Conclusion. Diabetes affects the tear film in various ways. Diabetics should be examined for dry eye signs even in absence of symptoms which may be masked by associated neuropathy. Duration of diabetes has an impact on tear film status.

  18. TFOS DEWS II Tear Film Report.

    PubMed

    Willcox, Mark D P; Argüeso, Pablo; Georgiev, Georgi A; Holopainen, Juha M; Laurie, Gordon W; Millar, Tom J; Papas, Eric B; Rolland, Jannick P; Schmidt, Tannin A; Stahl, Ulrike; Suarez, Tatiana; Subbaraman, Lakshman N; Uçakhan, Omür Ö; Jones, Lyndon

    2017-07-01

    The members of the Tear Film Subcommittee reviewed the role of the tear film in dry eye disease (DED). The Subcommittee reviewed biophysical and biochemical aspects of tears and how these change in DED. Clinically, DED is characterized by loss of tear volume, more rapid breakup of the tear film and increased evaporation of tears from the ocular surface. The tear film is composed of many substances including lipids, proteins, mucins and electrolytes. All of these contribute to the integrity of the tear film but exactly how they interact is still an area of active research. Tear film osmolarity increases in DED. Changes to other components such as proteins and mucins can be used as biomarkers for DED. The Subcommittee recommended areas for future research to advance our understanding of the tear film and how this changes with DED. The final report was written after review by all Subcommittee members and the entire TFOS DEWS II membership. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Spatiotemporal evolution of premonitory fault slip prior to stick-slip instability: New insight into the earthquake preparation

    NASA Astrophysics Data System (ADS)

    Zhuo, Y. Q.; Liu, P.; Guo, Y.; Ji, Y.; Ma, J.

    2017-12-01

    Premonitory fault slip, which begins with quasistatic propagation followed by quasidynamic propagation, may be a key clue bridging the "stick" state and "slip" state of a fault. More attentions have been paid for a long time to the temporal resolution of measurement than the spatial resolution, leading to the incomplete interpretation for the spatial evolution of premonitory slip, particularly during the quasistatic phase. In the present study, measurement of the quasistatic propagation of premonitory slip is achieved at an ultrahigh spatial resolution via a digital image correlation method. Multiple premonitory slip zones are observed and found to be controlled spatially by the fault contact heterogeneity, particularly the strong contact patches that prevent the propagation of premonitory slip and accumulate strain. As a result, premonitory slip is accelerated within constrained week contact spaces and consequently triggers the breakout of quasidynamic propagation. The results provide new insights into the quasistatic propagation of premonitory slip and may offer new interpretations for the earthquake nucleation process. This work is fund by the National Natural Science Foundation of China (Grant No. 41572181), the Basic Scientific Funding of Chinese National Nonprofit Institutes (Grant No. IGCEA1415, IGCEA1525), and the Early-Stage Work of Key Breakthrough Plan in Seismology from China Earthquake Administration.

  20. Tear dynamics in healthy and dry eyes.

    PubMed

    Cerretani, Colin F; Radke, C J

    2014-06-01

    Dry-eye disease, an increasingly prevalent ocular-surface disorder, significantly alters tear physiology. Understanding the basic physics of tear dynamics in healthy and dry eyes benefits both diagnosis and treatment of dry eye. We present a physiological-based model to describe tear dynamics during blinking. Tears are compartmentalized over the ocular surface; the blink cycle is divided into three repeating phases. Conservation laws quantify the tear volume and tear osmolarity of each compartment during each blink phase. Lacrimal-supply and tear-evaporation rates are varied to reveal the dependence of tear dynamics on dry-eye conditions, specifically tear osmolarity, tear volume, tear-turnover rate (TTR), and osmotic water flow. Predicted periodic-steady tear-meniscus osmolarity is 309 and 321 mOsM in normal and dry eyes, respectively. Tear osmolarity, volume, and TTR all match available clinical measurements. Osmotic water flow through the cornea and conjunctiva contribute 10 and 50% to the total tear supply in healthy and dry-eye conditions, respectively. TTR in aqueous-deficient dry eye (ADDE) is only half that in evaporative dry eye (EDE). The compartmental periodic-steady tear-dynamics model accurately predicts tear behavior in normal and dry eyes. Inclusion of osmotic water flow is crucial to match measured tear osmolarity. Tear-dynamics predictions corroborate the use of TTR as a clinical discriminator between ADDE and EDE. The proposed model is readily extended to predict the dynamics of aqueous solutes such as drugs or fluorescent tags.

  1. Earthquake Clustering on Normal Faults: Insight from Rate-and-State Friction Models

    NASA Astrophysics Data System (ADS)

    Biemiller, J.; Lavier, L. L.; Wallace, L.

    2016-12-01

    Temporal variations in slip rate on normal faults have been recognized in Hawaii and the Basin and Range. The recurrence intervals of these slip transients range from 2 years on the flanks of Kilauea, Hawaii to 10 kyr timescale earthquake clustering on the Wasatch Fault in the eastern Basin and Range. In addition to these longer recurrence transients in the Basin and Range, recent GPS results there also suggest elevated deformation rate events with recurrence intervals of 2-4 years. These observations suggest that some active normal fault systems are dominated by slip behaviors that fall between the end-members of steady aseismic creep and periodic, purely elastic, seismic-cycle deformation. Recent studies propose that 200 year to 50 kyr timescale supercycles may control the magnitude, timing, and frequency of seismic-cycle earthquakes in subduction zones, where aseismic slip transients are known to play an important role in total deformation. Seismic cycle deformation of normal faults may be similarly influenced by its timing within long-period supercycles. We present numerical models (based on rate-and-state friction) of normal faults such as the Wasatch Fault showing that realistic rate-and-state parameter distributions along an extensional fault zone can give rise to earthquake clusters separated by 500 yr - 5 kyr periods of aseismic slip transients on some portions of the fault. The recurrence intervals of events within each earthquake cluster range from 200 to 400 years. Our results support the importance of stress and strain history as controls on a normal fault's present and future slip behavior and on the characteristics of its current seismic cycle. These models suggest that long- to medium-term fault slip history may influence the temporal distribution, recurrence interval, and earthquake magnitudes for a given normal fault segment.

  2. Characteristics of radial tears in the posterior horn of the medial meniscus compared to horizontal tears.

    PubMed

    Choi, Chul-Jun; Choi, Yun-Jin; Song, In-Bum; Choi, Chong-Hyuk

    2011-06-01

    The clinical and radiologic features of radial tears of the medial meniscus posterior horn were compared with those of horizontal tears. From January 2007 to December 2008, 387 consecutive cases of medial meniscal tears were treated arthroscopically. Among these, 91 were radial tears in the medial meniscus posterior horn, and 95 were horizontal tears in the posterior segment of the medial meniscus. The patients' data (age, gender, duration of symptom, body mass index, and injury history), radiographic findings (Kellgren and Lawrence score, posterior tibial slope, and femorotibial angle), and chondral lesions were recorded. The patient factors of age, gender, and body mass index were related to radial tears of the medial meniscus posterior horn. Radial tears were significantly correlated with Kellgren and Lawrence score, varus alignment, posterior tibial slope, and severity of the chondral lesion. Radial tears of the medial meniscus posterior horn are a unique clinical entity that are associated with older age, females and obesity, and are strongly associated with an increased incidence and severity of cartilage degeneration compared to horizontal tears.

  3. Tear analysis in contact lens wearers.

    PubMed Central

    Farris, R L

    1985-01-01

    Tear analysis in contact lens wearers was compared with tear analysis in aphakics without contact lens wear and normal phakic patients. Subjects were divided into five groups: group 1, aphakic without contact lens; group 2, phakic with daily-wear hard contact lens; group 3, phakic with daily-wear soft contact lens; group 4, phakic with extended-wear soft contact lens; and group 5, aphakic with extended-wear soft contact lens. The experimental groups were compared with age- and sex-matched control groups for statistical analysis of tear variables by means of the Student's t-test. The variables measured were tear osmolarity, tear albumin, and lysozyme and lactoferrin concentrations in basal and reflex tears. Highly significant elevations of tear osmolarity were found in aphakic subjects without contact lenses. Less significant differences in tear osmolarity were found in phakic subjects with hard daily-wear lenses or with extended-wear soft lenses. Tear albumin, lysozyme, and lactoferrin in basal and reflex tears were not significantly different in the different groups of contact lens wearers or in the group of aphakic subjects without contact lenses compared with their control groups. Individual variations in tear albumin, lysozyme, and lactoferrin appeared to be responsible for the inability to demonstrate significant differences in tear composition in association with the wearing of different types of contact lenses. Older and aphakic patients demonstrated a tendency to have increased concentrations of proteins in the tears compared with younger, phakic contact lens wearers and normal controls without contact lenses. PMID:3914131

  4. Quantitative analysis of tear film fluorescence and discomfort during tear film instability and thinning.

    PubMed

    Begley, Carolyn; Simpson, Trefford; Liu, Haixia; Salvo, Eliza; Wu, Ziwei; Bradley, Arthur; Situ, Ping

    2013-04-12

    The purpose of this study was to test the association between tear film fluorescence changes during tear break-up (TBU) or thinning and the concurrent ocular sensory response. Sixteen subjects kept one eye open as long as possible (MBI), indicated their discomfort level continuously, and rated ocular sensations of irritation, stinging, burning, pricking, and cooling using visual analog scales (VAS). Fluorescence of the tear film was quantified by a pixel-based analysis of the median pixel intensity (PI), TBU, and percentage of dark pixels (DarkPix) over time. A cutoff of 5% TBU was used to divide subjects into either break-up (BU) or minimal break-up (BUmin) groups. Tear film fluorescence decreased (median PI) and the percentage of TBU and DarkPix increased in all trials, with the rate significantly greater in the BU than the BUmin group (Mann-Whitney U test, P < 0.05). The rate of increasing discomfort during trials was highly correlated with the rate of decrease in median PI and developing TBU (Spearman's, r ≥ 0.70). Significant correlations were found between corneal fluorescence, MBI, and sensory measures. Concentration quenching of fluorescein dye with tear film thinning best explains decreasing tear film fluorescence during trials. This was highly correlated with increasing ocular discomfort, suggesting that both tear film thinning and TBU stimulate underlying corneal nerves, although TBU produced more rapid stimulation. Slow increases in tear film hyperosmolarity may cause the gradual increase in discomfort during slow tear film thinning, whereas the sharp increases in discomfort during TBU suggest a more complex stimulus.

  5. Partial articular-sided rotator cuff tears: in situ repair versus tear completion prior to repair.

    PubMed

    Sethi, Paul M; Rajaram, Arun; Obopilwe, Elifho; Mazzocca, Augustus D

    2013-06-01

    Uncertainty exists over the ideal surgical treatment method for partial articular-sided rotator cuff tears, with options ranging from debridement to in situ repair to tear completion prior to repair. The purpose of this study was to determine whether in situ repair was a viable biomechanical treatment option compared with tear completion prior to repair of partial articular-sided rotator cuff tears. Fourteen fresh-frozen cadaveric shoulders were dissected. Partial articular-sided tears were created and repaired using in situ repair or tear completion prior to the repair. Strain and displacement were measured at 45°, 60°, and 90° of glenohumeral abduction. Testing was performed with a load of 100 N applied for 30 cycles. Data from the biomechanical testing displayed 4 conditions that showed improved characteristics of in situ repair over completion and repair: bursal-sided strain anteriorly at 45°, bursal-sided strain anteriorly at 90°, bursal-sided displacement anteriorly at 45°, and bursal-sided displacement anteriorly at 90°. The data indicate that in situ repair is a viable biomechanical treatment option compared with tear completion prior to repair of partial articular-sided rotator cuff tears. When clinically appropriate, the in situ repair may offer some biomechanical advantages, with lower strain and displacement observed on the bursal side compared with tear completion prior to repair. Copyright 2013, SLACK Incorporated.

  6. Tear-Duct Obstruction and Surgery

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español Tear-Duct Obstruction and Surgery KidsHealth / For Parents / Tear- ... year old with little or no treatment. About Tear Ducts Our eyes are continually exposed to dust, ...

  7. Does partial tear repair of adjacent tendons improve the outcome of supraspinatus tendonfull-thickness tear reinsertion?

    PubMed

    Nich, C; Dhiaf, N; Di Schino, M; Augereau, B

    2014-11-01

    Partial tearing of the infraspinatus and/or subscapularis tendon(s) is frequently associated with supraspinatus full-thickness tears. However, limited data regarding its influence on supraspinatus surgical repair is available. Our aim was to assess the functional and anatomical outcomes of open repair of supraspinatus full-thickness tears combined with adjacent partial tearing, comparatively to a control. We retrospectively identified 22 patients (22 shoulders) with a partial tear, most of them being a delamination tear, of the infraspinatus and/or subscapularis tendons associated with a complete detachment of the supraspinatus tendon. Twenty-seven patients (27 shoulders) treated for an isolated complete detachment of the supraspinatus tendon by open repair served as controls. The mean age was 58 years. A proximalized trans-osseous reinsertion of the supraspinatus tendon was combined with a curettage-closure of the delamination tear. Patients were evaluated with standardized MRI at last follow-up. At a mean of 75-month follow-up, the presence of a partial tear of either infraspinatus or subscapularis, or both, did not influence function and healing rates of supraspinatus tendon repair. Conversely to the control, when a retear occurred, the functional score tended to worsen. Preoperatively, fatty muscular degeneration was more pronounced when a partial tear was present. Fatty degeneration worsened regardless of repair healing. Open reinsertion of a supraspinatus full-thickness tear associated with a thorough treatment of partial tear of adjacent tendons led to optimal functional and anatomical mid term outcomes. Our results suggest the presence of a partial tear of adjacent tendons could be associated with poorer function in case of supraspinatus tendon re-rupture. Level III case-control study. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  8. Deep crustal faults and the origin and long-term flank stability of Mt. Etna : First results from the CIRCEE cruise (Oct. 2013)

    NASA Astrophysics Data System (ADS)

    Gutscher, Marc-Andre; Dominguez, Stephane; Mercier de Lepinay, Bernard; Pinheiro, Luis; Babonneau, Nathalie; Cattaneo, Antonio; LeFaou, Yann; Barreca, Giovanni; Micallef, Aaron; Rovere, Marzia

    2014-05-01

    The relation between deep crustal faults and the origin of Mount Etna, the largest and most active volcano in Europe has long been suspected due to its unusual geodynamic location. Results from a new marine geophysical survey offshore Eastern Sicily reveal the detailed geometry (location, length, dip and orientation) of a two-branched 200-km long, lithospheric scale fault system, long sought for as being the cause of Mount Etna. Using high-resolution bathymetry and seismic profiling, we image a 60-km long, previously unidentified, NW trending fault with evidence of recent displacement at the seafloor, offsetting Holocene sediments. This newly identified fault connects NE of Catania, to a known 40-km long, offshore-onshore fault system dissecting the southeastern flank of Mount Etna, generally interpreted as purely gravitational collapse structures. Geological and morphological field studies together with earthquake focal mechanisms indicate active dextral strike-slip motion along the onshore and shallow offshore portion of this 40 + 60 km long segment. The southern 100 km branch of the fault is associated with a sub-vertical lithospheric scale tear fault showing pure down to the East normal faulting and a 500+m thick elongate basin marked by syn-tectonic Plio-quaternary sediment fill. Together they represent two kinematically distinct strands of the long sought "STEP" (Subduction Tear Edge Propagator) fault, whose expression at depth controls the position of Mount Etna. Both 100-km long branches of the fault system are mechanically capable of generating magnitude 7 earthquakes (e.g. - like the 1693 Catania earthquake, the strongest in Italian history, causing 40,000 deaths). We conclude this deep-rooted lithospheric weakness guides gradual down slope creep of Mount Etna and may lead to long-term catastrophic flank collapse with associated tsunami by large-scale mass wasting.

  9. Artificial tears potpourri: a literature review

    PubMed Central

    Moshirfar, Majid; Pierson, Kasey; Hanamaikai, Kamalani; Santiago-Caban, Luis; Muthappan, Valliammai; Passi, Samuel F

    2014-01-01

    Numerous brands and types of artificial tears are available on the market for the treatment of dysfunctional tear syndrome. Past literature has focused on comparing the components of these products on patient’s clinical improvement. The wide array of products on the market presents challenges to both clinicians and patients when trying to choose between available tear replacement therapies. Different formulations affect patients based on etiology and severity of disease. In order to provide an unbiased comparison between available tear replacement therapies, we conducted a literature review of existing studies and National Institutes of Health clinical trials on commercially available, brand name artificial tears. Outcomes evaluated in each study, as well as the percent of patients showing clinical and symptomatic improvement, were analyzed. Fifty-one studies evaluating different brands of artificial tears, and their efficacy were identified. Out of the 51 studies, 18 were comparison studies testing brand name artificial tears directly against each other. Nearly all formulations of artificial tears provided significant benefit to patients with dysfunctional tear syndrome, but some proved superior to others. From the study data, a recommended treatment flowchart was derived. PMID:25114502

  10. 49 CFR 178.1070 - Tear test.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Tear test. 178.1070 Section 178.1070... Containers § 178.1070 Tear test. (a) General. The tear test must be conducted for the qualification of all of Flexible Bulk Containers design types. (b) Special preparation for the tear test. Flexible Bulk Container...

  11. Effects of Menthol-Containing Artificial Tears on Tear Stimulation and Ocular Surface Integrity in Normal and Dry Eye Rat Models.

    PubMed

    Ahn, Somin; Eom, Youngsub; Kang, Boram; Park, Jungboung; Lee, Hyung Keun; Kim, Hyo Myung; Song, Jong Suk

    2018-05-01

    To evaluate the effects of menthol-containing artificial tears on tear stimulation and ocular surface integrity in normal and dry eye rat models. A total of 54 male Lewis rats were used. The levels of tear secretion and tear MUC5AC concentrations were compared between the menthol-containing artificial tear-treated group (menthol group) and the vehicle-treated group (vehicle group). The groups were compared after a single instillation to evaluate the immediate effects, and after repeated instillation (five times a day for 5 days) to evaluate the longer-term effects. Tear lactate dehydrogenase (LDH) activity was measured to evaluate eye drop instillation-induced ocular surface damage. The effects of menthol-containing artificial tears were also evaluated in a dry eye rat model. After a single instillation of menthol-containing artificial tears, tear secretion increased from 4.37 (±0.75) mm at baseline to 7.37 (±1.60) mm. However, after repeated instillations, the effects of tear stimulation decreased. The tear MUC5AC concentration was significantly lower in the menthol group than in the vehicle group after a single instillation, but not after repeated instillation. However, the tear LDH concentration was significantly increased in the menthol group after repeated instillation. In the dry eye rat model, the extent of menthol-induced tear stimulation was reduced. Menthol-containing artificial tears increased tear secretion, but lowered the tear MUC5AC concentration. Menthol-induced tear stimulation was reduced after repeated instillation for 5 days and in the dry eye rat model. Conversely, repeated instillation of menthol-induced ocular surface damage, resulting in increased tear LDH activity.

  12. 49 CFR 178.818 - Tear test.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Tear test. 178.818 Section 178.818 Transportation... Tear test. (a) General. The tear test must be conducted for the qualification of all flexible IBC design types. (b) Special preparation for the tear test. The flexible IBC must be filled to not less than...

  13. 49 CFR 178.818 - Tear test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Tear test. 178.818 Section 178.818 Transportation... § 178.818 Tear test. (a) General. The tear test must be conducted for the qualification of all flexible IBC design types. (b) Special preparation for the tear test. The flexible IBC must be filled to not...

  14. Effects of topical cyclosporine a plus artificial tears versus artificial tears treatment on conjunctival goblet cell density in dysfunctional tear syndrome.

    PubMed

    Demiryay, Elvan; Yaylali, Volkan; Cetin, Ebru Nevin; Yildirim, Cem

    2011-09-01

    The aim was to compare the effects of topical cyclosporine A and artificial tears combination with artificial tears alone in patients with dysfunctional tear syndrome (DTS). Forty-two eyes of 42 patients with DTS were enrolled in the study. The inclusion criteria for the study were Schirmer I (without anesthesia) scores below 10 mm/5 min and tear film break-up time (BUT) below 10 sec. The patients were randomly divided into two groups. The study group (22 patients) underwent 0.05% cyclosporine A treatment twice a day and preservative-free artificial tears for four times a day for 4 months. The control group (20 patients) was administered only preservative-free artificial tears four times a day for 4 months. The BUT, Schirmer test scores, corneal fluorescein staining, conjunctival lissamine green staining, and goblet cell density derived by impression cytology were recorded before and after treatment in each group. In the study group, all parameters improved statistically significantly after treatment at the 4-month follow-up compared with the pretreatment values (P<0.001 for all). In the control group, corneal fluorescein staining (P<0.001) and conjunctival lissamine green staining (P=0.014) improved, but BUT and Schirmer scores did not change significantly after treatment. At the end of the 4-month follow-up, the study group demonstrated statistically significantly better BUT (P=0.020), Schirmer scores (P=0.002), goblet cell density (P=0.006), corneal fluorescein staining (P=0.003), and conjunctival lissamine green staining (P=0.017) scores than did the control group. Topical cyclosporine A and artificial tears treatment significantly increases goblet cell density, decreases the signs of DTS, and improves ocular surface health.

  15. Anterior Segment Optical Coherence Tomography for Tear Meniscus Evaluation and its Correlation with other Tear Variables in Healthy Individuals

    PubMed Central

    Dhasmana, Renu; Nagpal, Ramesh Chander

    2016-01-01

    Introduction Dry eye is one of the most common ocular diseases in this cyber era. Despite availability of multiple tests, no single test is accurate for the diagnosis of dry eye. Anterior segment optical coherence tomography is the recent tool which can be added in the armentarium of dry eye tests. Aim To evaluate tear meniscus with anterior segment optical coherence tomography and its correlation with other tear variables in normal healthy individuals. Materials and Methods In this prospective cross-sectional observational study, right eye of 203 consecutive patients were studied. All the patients were divided into three groups Group 1, 2 and 3 according to their age ≤20 years, 21-40 years and >40 years respectively. All patients underwent routine ophthalmologic examinations along with slit-lamp bio-microscopy for tear meniscus height measurement, tear film break up time, Schirmer’s I test (with anaesthesia) and optical coherence tomography imaging of inferior tear meniscus height. After focusing of the instrument with a Cross Line (CL) centered on lower tear meniscus at 6’0 clock of cornea, a 6 mm long scan was obtained. The tear meniscus height (μm) and tear meniscus area (mm2) were measured manually with help of callipers by joining upper corneo-meniscus junction to the lower lid-meniscus junction and tear meniscus height and area within the plotted line respectively and calculated by using the integrated analysis available in the custom software. Results There was significant decrease in the all tear variables with the increase in the age. According to age groups in group 1, the mean Schirmer’s (24.0±4.9)mm, tear film break up time (11.1±1.9) sec, tear meniscus height on slit lamp (600.2±167.3)mm were higher but decreased in group 2 (21.5±5.4,10.8±1.4, 597.5±186.3) and group 3 (19.8 ± 5.1, 10.2 ± 1.6, 485.6 ± 157.7) respectively. Schirmer’s test values and tear film break up time were similar in both sexes (p=0.1 and p= 0.9). Tear meniscus

  16. Hot tearing studies in AA5182

    NASA Astrophysics Data System (ADS)

    van Haaften, W. M.; Kool, W. H.; Katgerman, L.

    2002-10-01

    One of the major problems during direct chill (DC) casting is hot tearing. These tears initiate during solidification of the alloy and may run through the entire ingot. To study the hot tearing mechanism, tensile tests were carried out in semisolid state and at low strain rates, and crack propagation was studied in situ by scanning electron microscopy (SEM). These experimentally induced cracks were compared with hot tears developed in an AA5182 ingot during a casting trial in an industrial research facility. Similarities in the microstructure of the tensile test specimens and the hot tears indicate that hot tearing can be simulated by performing tensile tests at semisolid temperatures. The experimental data were compared with existing hot tearing models and it was concluded that the latter are restricted to relatively high liquid fractions because they do not take into account the existence of solid bridges in the crack.

  17. Ultrasound determination of rotator cuff tear repairability

    PubMed Central

    Tse, Andrew K; Lam, Patrick H; Walton, Judie R; Hackett, Lisa

    2015-01-01

    Background Rotator cuff repair aims to reattach the torn tendon to the greater tuberosity footprint with suture anchors. The present study aimed to assess the diagnostic accuracy of ultrasound in predicting rotator cuff tear repairability and to assess which sonographic and pre-operative features are strongest in predicting repairability. Methods The study was a retrospective analysis of measurements made prospectively in a cohort of 373 patients who had ultrasounds of their shoulder and underwent rotator cuff repair. Measurements of rotator cuff tear size and muscle atrophy were made pre-operatively by ultrasound to enable prediction of rotator cuff repairability. Tears were classified following ultrasound as repairable or irreparable, and were correlated with intra-operative repairability. Results Ultrasound assessment of rotator cuff tear repairability has a sensitivity of 86% (p < 0.0001) and a specificity of 67% (p < 0.0001). The strongest predictors of rotator cuff repairability were tear size (p < 0.001) and age (p = 0.004). Sonographic assessments of tear size ≥4 cm2 or anteroposterior tear length ≥25 mm indicated an irreparable rotator cuff tear. Conclusions Ultrasound assessment is accurate in predicting rotator cuff tear repairability. Tear size or anteroposterior tear length and age were the best predictors of repairability. PMID:27582996

  18. Plasminogen activator activity in tears of pregnant women.

    PubMed

    Csutak, Adrienne; Steiber, Zita; Tőzsér, József; Jakab, Attila; Berta, András; Silver, David M

    2017-01-01

    Plasminogen activator activity (PAA) in tears of pregnant women was investigated at various gestation times to assess the availability of plasminogen activator for aiding potential corneal wound healing processes during pregnancy. PAA was measured by a spectrophotometric method. The analysis used 91 tear samples from pregnant and non-pregnant women, supplemented with 10 additional tear PAA measurements from non-pregnant women obtained in a previous study. Tear levels of PAA in pregnant women formed a bimodal distribution. Either the tear PAA level was zero or non-zero during pregnancy. When non-zero, the tear PAA level was dissociated from gestation time and not different than non-pregnant and post-pregnant levels. The frequency of occurrence of zero level tear PAA increased with gestation: 16%, 17% and 46% had zero tear PAA in samples taken from women in the first, second and third trimester, respectively. Overall, of the tear samples taken from women during pregnancy, a total of 26% were at zero tear PAA. The remaining tear samples had non-zero tear PAA values throughout gestation equivalent to non-pregnant tear PAA values, suggesting local control of the source of PAA in tears. Given the importance of the plasminogen activator system in tears to wound healing in the cornea, and the high occurrence of zero tear PAA in our sample of pregnant women, elective corneal surgery would be contraindicated. If corneal surgery is nevertheless necessary, the tear PAA level would be worth checking and patients with low level should be closely observed during the postoperative period.

  19. Self-folding mechanics of graphene tearing and peeling from a substrate

    NASA Astrophysics Data System (ADS)

    He, Ze-Zhou; Zhu, Yin-Bo; Wu, Heng-An

    2018-06-01

    Understanding the underlying mechanism in the tearing and peeling processes of graphene is crucial for the further hierarchical design of origami-like folding and kirigami-like cutting of graphene. However, the complex effects among bending moduli, adhesion, interlayer interaction, and local crystal structure during origami-like folding and kirigami-like cutting remain unclear, resulting in challenges to the practical applications of existing theoretical and experimental findings as well as to potential manipulations of graphene in metamaterials and nanodevices. Toward this end, classical molecular dynamics (MD) simulations are performed with synergetic theoretical analysis to explore the tearing and peeling of self-folded graphene from a substrate driven by external force and by thermal activation. It is found that the elastic energy localized at the small folding ridge plays a significant role in the crack trajectory. Due to the extremely small bending modulus of monolayer graphene, its taper angle when pulled by an external force follows a scaling law distinct from that in case of bilayer graphene. With the increase in the initial width of the folding ridge, the self-folded graphene, motivated by thermal fluctuations, can be self-assembled by spontaneous self-tearing and peeling from a substrate. Simultaneously, the scaling law between the taper angle and adhesive energy is independent of the motivations for thermal activation-induced self-assembly and external force tearing, providing effective insights into the underlying physics for graphene-based origami-like folding and kirigami-like cutting.

  20. Switches in subduction polarity, slab tearing and the opening of slab gaps along the Alpine chain - a view from the bottom up

    NASA Astrophysics Data System (ADS)

    Handy, M. R.; Ustaszewski, K. M.; Kissling, E. H.

    2013-12-01

    Kinematic reconstructions of the Alpine orogen from Late Cretaceous to present time reveal that slab tearing and switches of subduction polarity are related to two slab gaps presently imaged as low-velocity anomalies at the transition of the Eastern and Central Alps, and beneath the northern Dinarides. A lithosphere-scale transfer fault at the Alps-Dinarides join (ADT) linked S-directed subduction of the oceanic part of the European plate in the Alps with N-directed subduction of the continental part of the Adriatic plate in the Dinarides in Late Cretaceous to Paleogene time. Transfer faulting in the Dinarides was initially situated along a suture zone, then jumped westward no later than 40 Ma as thrusting and subduction affected more external units of the Alps and Dinarides. Late Eocene Alpine collision led to a slowing of Adria-Europe convergence and initial rupturing of the European and Adriatic slabs in Eocene-Oligocene time, when most of the oceanic lithosphere broke off. This thermally preconditioned the lithosphere for a radical reorganization of slabs and mantle flow in the Alpine domain beginning in early Miocene time. This included the onset of Carpathian rollback subduction, as well as counterclockwise rotation and N-ward subduction of Adriatic continental lithosphere into the space beneath the Eastern Alps that was vacated by foundering and renewed tearing of the European slab in Oligocene-early Miocene time. Our plate reconstructions indicate that this tear nucleated at the tip of a subducted sliver of European continental lithosphere coinciding with the present location of the narrow slab gap between the Eastern and Central Alps. This tear then propagated horizontally to the NE along the subducted boundary of the European margin and the Carpathian embayment of the Alpine Tethyan ocean. The surface response to slab tearing included peneplainization and uplift of part of the Eastern Alps. Transfer faulting along the ADT gave way to back-arc extension

  1. [The correlations between corneal sensation, tear meniscus volume, and tear film osmolarity after femtosecond laser-assisted LASIK].

    PubMed

    Zhang, Luyan; Sun, Xiyu; Yu, Ye; Xiong, Yan; Cui, Yuxin; Wang, Qinmei; Hu, Liang

    2016-01-01

    To investigate the correlations between corneal sensation, tear meniscus volume, and tear film osmolarity after femtosecond laser-assisted LASIK (FS-LASIK) surgery. In this prospective clinical study, 31 patients undergoing FS-LASIK for myopia were recruited. The upper and lower tear meniscus volumes (UTMV and LTMV) were measured by customized anterior segment optical coherence tomography, tear film osmolarity was measured by a TearLab Osmolarity test device, central corneal sensation was measured by a Cochet-Bonner esthesiometer preoperatively, at 1 week, 1 and 3 months postoperatively. Repeated measures analysis of variance was used to evaluate whether the tear film osmolarity, tear meniscus volume, and corneal sensation were changed after surgery. The correlations between these variables were analyzed by the Pearson correlation analysis. The tear film osmolarity was (310.03 ± 16.48) mOsms/L preoperatively, (323.51 ± 15.92) mOsms/L at 1 week, (319.93 ± 14.27) mOsms/L at 1 month, and (314.97±12.91) mOsms/L at 3 months. The UTMV was (0.42±0.15), (0.25± 0.09), (0.30±0.11), and (0.35±0.09) μL, respectively; the LTMV was (0.60±0.21),(0.37±0.08), (0.44± 0.14), and (0.52±0.17) μL, respectively. The tear film osmolarity was significantly higher at 1 week and 1 month postoperatively compared with the baseline (P=0.001, 0.004), and reduced to the preoperative level at 3 months (P=0.573). The UTMV, LTMV, and corneal sensation values presented significant decreases at all postoperative time points (all P<0.05). The Pearson correlation analysis showed the postoperative UTMV had a weak relationship with corneal sensation at 1 week after surgery (r=0.356,P=0.005). There were significant correlations between the preoperative LTMV and corneal sensation at 1 week, 1 and 3 months (respectively, r=0.422, 0.366, 0.352;P=0.001, 0.004, 0.006). No significant correlations were found between the tear film osmolarity, tear meniscus volume, and corneal sensation after surgery

  2. Tears of Wine

    NASA Astrophysics Data System (ADS)

    Rathore, Prerana; Sharma, Vivek

    `Tears of wine' refer to the rows of wine-drops that spontaneously emerge within a glass of strong wine. Evaporation-driven Marangoni flows near the meniscus of water-alcohol mixtures drive liquid upward forming a thin liquid film, and a rim or ridge forms near the moving contact line. Eventually the rim undergoes an instability forming drops, that roll back into bulk reservoir forming so called tears or legs of wine. Most studies in literature argue the evaporation of more volatile, lower surface tension component (alcohol) results in a concentration-dependent surface tension gradient that drives the climbing flow within the thin film. Though it is well-known that evaporative cooling can create temperature gradients that could provide additional contribution to the climbing flows, the role of thermocapillary flows is less well-understood. Furthermore, the patterns, flows and instabilities that occur near the rim, and determine the size and periodicity of tears, are not well-studied. Using experiments and theory, we visualize and analyze the formation and growth of tears of wine. The sliding drops, released from the rim towards the bulk reservoir, show oscillations and a cascade of fascinating flows that are analyzed for the first time.

  3. Tear exchange and contact lenses: A review

    PubMed Central

    Muntz, Alex; Subbaraman, Lakshman N.; Sorbara, Luigina; Jones, Lyndon

    2015-01-01

    Tear exchange beneath a contact lens facilitates ongoing fluid replenishment between the ocular surface and the lens. This exchange is considerably lower during the wear of soft lenses compared with rigid lenses. As a result, the accumulation of tear film debris and metabolic by-products between the cornea and a soft contact lens increases, potentially leading to complications. Lens design innovations have been proposed, but no substantial improvement in soft lens tear exchange has been reported. Researchers have determined post-lens tear exchange using several methods, notably fluorophotometry. However, due to technological limitations, little remains known about tear hydrodynamics around the lens and, to-date, true tear exchange with contact lenses has not been shown. Further knowledge regarding tear exchange could be vital in aiding better contact lens design, with the prospect of alleviating certain adverse ocular responses. This article reviews the literature to-date on the significance, implications and measurement of tear exchange with contact lenses. PMID:25575892

  4. Electronic enhancement of tear secretion

    NASA Astrophysics Data System (ADS)

    Brinton, Mark; Lim Chung, Jae; Kossler, Andrea; Kook, Koung Hoon; Loudin, Jim; Franke, Manfred; Palanker, Daniel

    2016-02-01

    Objective. To study electrical stimulation of the lacrimal gland and afferent nerves for enhanced tear secretion, as a potential treatment for dry eye disease. We investigate the response pathways and electrical parameters to safely maximize tear secretion. Approach. We evaluated the tear response to electrical stimulation of the lacrimal gland and afferent nerves in isofluorane-anesthetized rabbits. In acute studies, electrical stimulation was performed using bipolar platinum foil electrodes, implanted beneath the inferior lacrimal gland, and a monopolar electrode placed near the afferent ethmoid nerve. Wireless microstimulators with bipolar electrodes were implanted beneath the lacrimal gland for chronic studies. To identify the response pathways, we applied various pharmacological inhibitors. To optimize the stimulus, we measured tear secretion rate (Schirmer test) as a function of pulse amplitude (1.5-12 mA), duration (0.1-1 ms) and repetition rate (10-100 Hz). Main results. Stimulation of the lacrimal gland increased tear secretion by engaging efferent parasympathetic nerves. Tearing increased with stimulation amplitude, pulse duration and repetition rate, up to 70 Hz. Stimulation with 3 mA, 500 μs pulses at 70 Hz provided a 4.5 mm (125%) increase in Schirmer score. Modulating duty cycle further increased tearing up to 57%, compared to continuous stimulation in chronically implanted animals (36%). Ethmoid (afferent) nerve stimulation increased tearing similar to gland stimulation (3.6 mm) via a reflex pathway. In animals with chronically implanted stimulators, a nearly 6 mm increase (57%) was achieved with 12-fold less charge density per pulse (0.06-0.3 μC mm-2 with 170-680 μs pulses) than the damage threshold (3.5 μC mm-2 with 1 ms pulses). Significance. Electrical stimulation of the lacrimal gland or afferent nerves may be used as a treatment for dry eye disease. Clinical trials should validate this approach in patients with aqueous tear deficiency, and

  5. Physical and Transport Properties of the carbonate-bearing faults: experimental insights from the Monte Maggio Fault zone (Central Italy)

    NASA Astrophysics Data System (ADS)

    Trippetta, Fabio; Scuderi, Marco Maria; Collettini, Cristiano

    2015-04-01

    Physical properties of fault zones vary with time and space and in particular, fluid flow and permeability variations are strictly related to fault zone processes. Here we investigate the physical properties of carbonate samples collected along the Monte Maggio normal Fault (MMF), a regional structure (length ~10 km and displacement ~500 m) located within the active system of the Apennines. In particular we have studied an exceptionally exposed outcrop of the fault within the Calcare Massiccio formation (massive limestone) that has been recently exposed by new roadworks. Large cores (100 mm in diameter and up to 20 cm long) drilled perpendicular to the fault plane have been used to: 1) characterize the damage zone adjacent to the fault plane and 2) to obtain smaller cores, 38 mm in diameter both parallel and perpendicular to the fault plane, for rock deformation experiments. At the mesoscale two types of cataclastic damage zones can be identified in the footwall block (i) a Cemented Cataclasite (CC) and (ii), a Fault Breccia (FB). Since in some portions of the fault the hangingwall (HW) is still preserved we also collected HW samples. After preliminary porosity measurements at ambient pressure, we performed laboratory measurements of Vp, Vs, and permeability at effective confining pressures up to 100 MPa in order to simulate crustal conditions. The protolith has a primary porosity of about 7 %, formed predominantly by isolated pores since the connected porosity is only 1%. FB samples are characterized by 10% and 5% of bulk and connected porosity respectively, whilst CC samples show lower bulk porosity (7%) and a connected porosity of 2%. From ambient pressure to 100 MPa, P-wave velocity is about 5,9-6,0 km/s for the protolith, ranges from 4,9 km/s to 5,9 km/s for FB samples, whereas it is constant at 5,9 km/s for CC samples and ranges from 5,4 to 5,7 for HW sample. Vs shows the same behaviour resulting in a constant Vp/Vs ratio from 0 to 100 MPa that ranges from 1

  6. Dynamic interfacial properties of human tear-lipid films and their interactions with model-tear proteins in vitro.

    PubMed

    Svitova, Tatyana F; Lin, Meng C

    2016-07-01

    This review summarizes the current state of knowledge regarding interfacial properties of very complex biological colloids, specifically, human meibum and tear lipids, and their interactions with proteins similar to the proteins found in aqueous part of human tears. Tear lipids spread as thin films over the surface of tear-film aqueous and play crucial roles in tear-film stability and overall ocular-surface health. The vast majority of papers published to date report interfacial properties of meibum-lipid monolayers spread on various aqueous sub-phases, often containing model proteins, in Langmuir trough. However, it is well established that natural human ocular tear lipids exist as multilayered films with a thickness between 30 and 100nm, that is very much disparate from 1 to 2nm thick meibum monolayers. We employed sessile-bubble tensiometry to study the dynamic interfacial and rheological properties of reconstituted multilayered human tear-lipid films. Small amounts (0.5-1μg) of human tear lipids were deposited on an air-bubble surface to produce tear-lipid films in thickness range 30-100nm corresponding to ocular lipid films. Thus, we were able to overcome major Langmuir-trough method limitations because ocular tear lipids can be safely harvested only in minute, sub-milligram quantities, insufficient for Langmuir through studies. Sessile-bubble method is demonstrated to be a versatile tool for assessing conventional synthetic surfactants adsorption/desorption dynamics at an air-aqueous solution interface. (Svitova T., Weatherbee M., Radke C.J. Dynamics of surfactant sorption at the air/water interface: continuous-flow tensiometry. J. Colloid Interf. Sci. 2003;261:1170-179). The augmented flow-sessile-bubble setup, with step-strain relaxation module for dynamic interfacial rheological properties and high-precision syringe pump to generate larger and slow interfacial area expansions-contractions, was developed and employed in our studies. We established that

  7. Comparison of low-abundance biomarker levels in capillary-collected nonstimulated tears and washout tears of aqueous-deficient and normal patients.

    PubMed

    Guyette, Nicole; Williams, Larezia; Tran, My-Tho; Than, Tammy; Bradley, John; Kehinde, Lucy; Edwards, Clara; Beasley, Mark; Fullard, Roderick

    2013-05-01

    Low tear volume limits the use of nonstimulated (NS) microcapillary tear collection in aqueous-deficient (AD) patients. Adding a small amount of "washout" fluid to the eye prior to tear collection is a potentially viable alternative method for abundant proteins, but is relatively untested for low-abundance biomarkers. This study determined the feasibility of the washout (WO) method as an NS alternative for low-abundance biomarkers. NS and WO biomarker profiles were compared between AD patients and non-AD controls to determine if the two methods identify the same intergroup differences. Matching NS and WO tears were collected from 48 patients by micropipette, the WO sample after instillation of 10 μL saline. Tear cytokine levels were measured by 27-Plex Bio-Rad assay. Bland-Altman analyses for each biomarker determined the agreement between tear sample types. Patients were grouped as AD or non-AD based on Schirmer score to determine if NS profile between-group differences were preserved in WO tears. Bland-Altman plots showed good biomarker level agreement between NS and WO tears for most cytokines. Five biomarkers, among those most often cited as differing in AD dry eye, differed significantly between non-AD and AD groups in both tear types. Additional biomarker differences were seen in NS tears only. The WO tear collection method is a viable alternative to NS tears for many low-abundance biomarkers and is able to replicate major NS tear differences between dry eye groups. More subtle intergroup differences are lost in WO samples because of reduced statistical power.

  8. Differential protein expression in tears of patients with primary open angle and pseudoexfoliative glaucoma.

    PubMed

    Pieragostino, Damiana; Bucci, Sonia; Agnifili, Luca; Fasanella, Vincenzo; D'Aguanno, Simona; Mastropasqua, Alessandra; Ciancaglini, Marco; Mastropasqua, Leonardo; Di Ilio, Carmine; Sacchetta, Paolo; Urbani, Andrea; Del Boccio, Piero

    2012-04-01

    Primary open angle (POAG) and pseudoexfoliative glaucoma (PXG) are the most common primary and secondary forms of glaucoma, respectively. Even though the patho-physiology, aqueous humor composition, risk factors, clinical features, therapy and drug induced ocular surface changes in POAG and PXG have been widely studied, to date information concerning tear protein characterization is lacking. Tears are a source of nourishment for ocular surface tissues and a vehicle to remove local waste products, metabolized drugs and inflammatory mediators produced in several ophthalmic diseases. In glaucoma, the proteomic definition of tears may provide insights concerning patho-physiology of the disease and ocular surface modifications induced by topical therapy. Our study aimed at characterizing protein patterns in tears of patients with medically controlled POAG and PXG. A comparative tears proteomic analysis by label-free LC-MS(E) highlighted differences in the expression of several proteins in the two glaucoma sub-types and control subjects, highlighting inflammation pathways expressed in both diseases. Results were independently reconfirmed by SDS-PAGE and linear MALDI-TOF MS, validating altered levels of Lysozyme C, Lipocalin-1, Protein S100, Immunoglobulins and Prolactin Inducible Protein. Moreover, we found a differential pattern of phosphorylated Cystatin-S that distinguishes the two pathologies. The most relevant results suggest that in both pathologies there may be active inflammation pathways related to the disease and/or induced by therapy. We show, for the first time, tear protein patterns expressed under controlled intraocular pressure conditions in POAG and PXG subjects. These findings could help in the understanding of molecular machinery underlying these ophthalmologic diseases, resulting in early diagnosis and more specific therapy.

  9. Warm and touching tears: tearful individuals are perceived as warmer because we assume they feel moved and touched.

    PubMed

    Zickfeld, Janis H; Schubert, Thomas W

    2018-01-31

    Recent work investigated the inter-individual functions of emotional tears in depth. In one study (Van de Ven, N., Meijs, M. H. J., & Vingerhoets, A. (2017). What emotional tears convey: Tearful individuals are seen as warmer, but also as less competent. British Journal of Social Psychology, 56(1), 146-160. Https://doi.org/10.1111/bjso.12162) tearful individuals were rated as warmer, and participants expressed more intentions to approach and help such individuals. Simultaneously, tearful individuals were rated as less competent, and participants expressed less intention to work with the depicted targets. While tearful individuals were perceived as sadder, perceived sadness mediated only the effect on competence, but not on warmth. We argue that tearful individuals might be perceived as warm because they are perceived as feeling moved and touched. We ran a pre-registered extended replication of Van de Ven et al. Results replicate the warmth and helping findings, but not the competence and work effects. The increase in warmth ratings was completely mediated by perceiving feeling moved and touched. Possible functions of feeling moved and touched with regard to emotional tears are discussed.

  10. Assay of mucins in human tear fluid.

    PubMed

    Spurr-Michaud, Sandra; Argüeso, Pablo; Gipson, Ilene

    2007-05-01

    Mucin genes, both secreted (MUC2, MUC5AC, MUC5B, MUC7) and membrane associated (MUC1, MUC4, MUC16), have been reported to be expressed by ocular surface epithelia. The purpose of this study was to comprehensively assay the mucin content of human tear fluid using multiple antibodies for each mucin and to develop a sensitive, semi-quantitative method for the assay of mucins in tears. Tear washes were obtained by instillation of saline onto the ocular surface, followed by collection from the inferior fornix. Tear proteins were separated in 1% agarose gels, transferred to nitrocellulose membrane by vacuum blotting and probed with multiple antibodies recognizing MUC1, MUC2, MUC4, MUC5AC, MUC5B, MUC7 and MUC16. Binding was detected using chemiluminescence, and quantity was determined by densitometry. Serial dilutions of pooled tears from normal individuals were assayed to determine the linear range of detectability. MUC1, MUC4, MUC16, MUC5AC and low levels of MUC2 were consistently detected in human tear fluid, while MUC5B and MUC7 were not. Use of several antibodies recognizing different epitopes on the same mucin confirmed these findings. The antibodies to mucins bound to serial dilutions of tears in a linear fashion (r2 > 0.9), indicating the feasibility of semi-quantitation. MUC5AC in tear fluid had an increased electrophoretic mobility compared to MUC5AC isolated from conjunctival tissue. This study provides clear evidence that the mucin component of tears is a mixture of secreted and shed membrane-associated mucins, and for the first time demonstrates MUC16 in tear fluid. Immunoblots of tears using agarose gel electrophoresis and chemiluminescence detection provide a semi-quantitative assay for mucin protein that will be useful for comparisons with tears from diseased eyes or after pharmacological intervention.

  11. Assay of Mucins in Human Tear Fluid

    PubMed Central

    Spurr-Michaud, Sandra; Argüeso, Pablo; Gipson, Ilene

    2007-01-01

    Mucin genes, both secreted (MUC2, MUC5AC, MUC5B, MUC7) and membrane associated (MUC1, MUC4, MUC16), have been reported to be expressed by ocular surface epithelia. The purpose of this study was to comprehensively assay the mucin content of human tear fluid using multiple antibodies for each mucin and to develop a sensitive, semi-quantitative method for the assay of mucins in tears. Tear washes were obtained by instillation of saline onto the ocular surface, followed by collection from the inferior fornix. Tear proteins were separated in 1% agarose gels, transferred to nitrocellulose membrane by vacuum blotting and probed with multiple antibodies recognizing MUC1, MUC2, MUC4, MUC5AC, MUC5B, MUC7 and MUC16. Binding was detected using chemiluminescence, and quantity was determined by densitometry. Serial dilutions of pooled tears from normal individuals were assayed to determine the linear range of detectability. MUC1, MUC4, MUC16, MUC5AC and low levels of MUC2 were consistently detected in human tear fluid, while MUC5B and MUC7 were not. Use of several antibodies recognizing different epitopes on the same mucin confirmed these findings. The antibodies to mucins bound to serial dilutions of tears in a linear fashion (r2 >0.9), indicating the feasibility of semi-quantitation. MUC5AC in tear fluid had an increased electrophoretic mobility compared to MUC5AC isolated from conjunctival tissue. This study provides clear evidence that the mucin component of tears is a mixture of secreted and shed membrane-associated mucins, and for the first time demonstrates MUC16 in tear fluid. Immunoblots of tears using agarose gel electrophoresis and chemiluminescence detection provide a semi-quantitative assay for mucin protein that will be useful for comparisons with tears from diseased eyes or after pharmacological intervention. PMID:17399701

  12. Tear exchange and contact lenses: a review.

    PubMed

    Muntz, Alex; Subbaraman, Lakshman N; Sorbara, Luigina; Jones, Lyndon

    2015-01-01

    Tear exchange beneath a contact lens facilitates ongoing fluid replenishment between the ocular surface and the lens. This exchange is considerably lower during the wear of soft lenses compared with rigid lenses. As a result, the accumulation of tear film debris and metabolic by-products between the cornea and a soft contact lens increases, potentially leading to complications. Lens design innovations have been proposed, but no substantial improvement in soft lens tear exchange has been reported. Researchers have determined post-lens tear exchange using several methods, notably fluorophotometry. However, due to technological limitations, little remains known about tear hydrodynamics around the lens and, to-date, true tear exchange with contact lenses has not been shown. Further knowledge regarding tear exchange could be vital in aiding better contact lens design, with the prospect of alleviating certain adverse ocular responses. This article reviews the literature to-date on the significance, implications and measurement of tear exchange with contact lenses. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  13. Solute Dynamics and Imaging in the Tear Film on an Eye-shaped Domain

    NASA Astrophysics Data System (ADS)

    Braun, R. J.; Li, Longfei; Henshaw, William; Driscoll, Tobin; King-Smith, P. E.

    2015-11-01

    The concentration of ions in the tear film (osmolarity) is a key variable in understanding dry eye symptoms and disease, yet its global distribution is not available; direct measurements are restricted to a region near the temporal canthus. It has been suggested that imaging methods that use solutes such as fluorescein can be used as a proxy for estimating the osmolarity. The concentration of fluorescein is not measured directly either but the intensity as a function of concentration and thickness of the film is well established. We derived a mathematical model that couples multiple solutes and fluid dynamics within the tear film on a 2D eye-shaped domain. The model includes the physical effects of evaporation, surface tension, viscosity, ocular surface wettability, osmolarity, osmosis, fluorescence and tear fluid supply and drainage. We solved the governing system of coupled nonlinear PDEs using the Overture computational framework developed at LLNL, together with a hybrid time stepping scheme (using variable step BDF and RKC). Results of our numerical simulations provide new insight about the osmolarity distribution and its connection with images obtained in vivo over the whole ocular surface and in local regions of tear thinning due to evaporation and other effects. This work was supported in part by NSF grants 1022706 and 1412085, and NIH grant 1R01EY021794.

  14. Reduced tear production in three canine endocrinopathies.

    PubMed

    Williams, D L; Pierce, V; Mellor, P; Heath, M F

    2007-05-01

    Previous reports have suggested that hypothyroid and diabetic patients can be predisposed to keratoconjunctivitis sicca. This study aimed to measure tear production in dogs with diabetes, hypothyroidism and hyperadrenocorticism using the Schirmer tear test and to compare these results with Schirmer tear test values for a group of normal dogs. Schirmer tear tests were performed on 16 dogs with hyperadrenocorticism, 18 with diabetes and 12 with hypothyroidism together with 100 control dogs. Corneal sensitivity was also measured in 12 of the 18 diabetic dogs with a Cochet Bonnet aesthesiometer and compared with age- and breed-matched normal dogs. Schirmer tear test values in dogs with hypothyroidism, hyperadrenocorticism and diabetes were 12.3+/-3.2, 14.0+/-4.0 and 12.3+/-5.3 mm/minutes, respectively. Schirmer tear test values were significantly lower than that for the control group (19.6+/-4.2 mm/minutes) in all dogs with an endocrinopathy. Only in two hypothyroid dogs and three diabetics, this was manifested as profound keratoconjunctivitis sicca with Schirmer tear test value lower than 5 mm/minutes. Diabetic dogs had significantly reduced corneal sensitivity compared with a matched set of control dogs. This study shows a significant reduction in tear production in animals with diabetes mellitus, hypothyroidism and hyperadrenocorticism. Further research is needed to elucidate the mechanisms by which this reduction in tear production occurs. Assessment of tear production should be undertaken in animals diagnosed with these endocrinopathies, as these animals may progress to clinical keratoconjunctivitis sicca.

  15. Fault-related fold styles and progressions in fold-thrust belts: Insights from sandbox modeling

    NASA Astrophysics Data System (ADS)

    Yan, Dan-Ping; Xu, Yan-Bo; Dong, Zhou-Bin; Qiu, Liang; Zhang, Sen; Wells, Michael

    2016-03-01

    Fault-related folds of variable structural styles and assemblages commonly coexist in orogenic belts with competent-incompetent interlayered sequences. Despite their commonality, the kinematic evolution of these structural styles and assemblages are often loosely constrained because multiple solutions exist in their structural progression during tectonic restoration. We use a sandbox modeling instrument with a particle image velocimetry monitor to test four designed sandbox models with multilayer competent-incompetent materials. Test results reveal that decollement folds initiate along selected incompetent layers with decreasing velocity difference and constant vorticity difference between the hanging wall and footwall of the initial fault tips. The decollement folds are progressively converted to fault-propagation folds and fault-bend folds through development of fault ramps breaking across competent layers and are followed by propagation into fault flats within an upper incompetent layer. Thick-skinned thrust is produced by initiating a decollement fault within the metamorphic basement. Progressive thrusting and uplifting of the thick-skinned thrust trigger initiation of the uppermost incompetent decollement with formation of a decollement fold and subsequent converting to fault-propagation and fault-bend folds, which combine together to form imbricate thrust. Breakouts at the base of the early formed fault ramps along the lowest incompetent layers, which may correspond to basement-cover contacts, domes the upmost decollement and imbricate thrusts to form passive roof duplexes and constitute the thin-skinned thrust belt. Structural styles and assemblages in each of tectonic stages are similar to that in the representative orogenic belts in the South China, Southern Appalachians, and Alpine orogenic belts.

  16. Interferometric characterization of tear film dynamics

    NASA Astrophysics Data System (ADS)

    Primeau, Brian Christopher

    The anterior refracting surface of the eye is the thin tear film that forms on the surface of the cornea. When a contact lens is on worn, the tear film covers the contact lens as it would a bare cornea, and is affected by the contact lens material properties. Tear film irregularity can cause both discomfort and vision quality degradation. Under normal conditions, the tear film is less than 10 microns thick and the thickness and topography change in the time between blinks. In order to both better understand the tear film, and to characterize how contact lenses affect tear film behavior, two interferometers were designed and built to separately measure tear film behavior in vitro and in vivo. An in vitro method of characterizing dynamic fluid layers applied to contact lenses mounted on mechanical substrates has been developed using a phase-shifting Twyman-Green interferometer. This interferometer continuously measures light reflected from the surface of the fluid layer, allowing precision analysis of the dynamic fluid layer. Movies showing this fluid layer behavior can be generated. The fluid behavior on the contact lens surface is measured, allowing quantitative analysis beyond what typical contact angle or visual inspection methods provide. The in vivo interferometer is a similar system, with additional modules included to provide capability for human testing. This tear film measurement allows analysis beyond capabilities of typical fluorescein visual inspection or videokeratometry and provides better sensitivity and resolution than shearing interferometry methods.

  17. Assessment of tear film osmolarity using the TearLab™ osmometer in normal dogs and dogs with keratoconjunctivitis sicca.

    PubMed

    Sebbag, Lionel; Park, Shin Ae; Kass, Philip H; Maggs, David J; Attar, Mayssa; Murphy, Christopher J

    2017-07-01

    To evaluate repeatability and reproducibility of tear osmolarity measured using the TearLab ™ osmometer in normal dogs and to assess its diagnostic potential in dogs with keratoconjunctivitis sicca (KCS). Beagle dogs; six normal and five with KCS. Tear osmolarity and Schirmer tear test-1 (STT-1) values were obtained at various times. Normal dogs were assessed for diurnal variation and repeatability and reproducibility of measurements. Dogs with KCS were evaluated before and after 5 months' topical twice-daily therapy with 2% cyclosporine. Mean ± SD tear osmolarity (mOsm/L) was significantly higher in normal dogs (337.4 ± 16.2) than in dogs with KCS before therapy (306.2 ± 18.0; P < 0.0001), but not following therapy with 2% cyclosporine (330.5 ± 13.7; P = 1.00). Osmolarity readings lower than 325.5 mOsm/L were suggestive of KCS (84.8% sensitivity and 87.1% specificity). In normal dogs, tear osmolarity readings were stable during the daytime (P = 0.99). Repeated measurements revealed high variability and typically poor-to-moderate repeatability and reproducibility, although this was improved by taking three successive measurements at each session. Considering combined data from all dogs, a positive correlation existed between STT-1 and tear osmolarity measurements (Pearson's correlation test, P = 0.04, r = 0.62). Canine tear osmolarity as determined by TearLab ™ osmometer was variable, required multiple readings to be informative, and differed from values reported for humans. Dogs with KCS had a lower tear osmolarity than did normal dogs, and this increased following cyclosporine therapy. © 2016 American College of Veterinary Ophthalmologists.

  18. [Shoulder instability and rotator cuff tear].

    PubMed

    Voigt, C; Lill, H

    2009-01-01

    A rotator cuff tear as a complication of anterior shoulder dislocation is well known in patients over 40 years old. The incidence of this accompanying injury correlates with the patient's age and the number of redislocations. The tear localization and dimension depend on the patient's age. To what extent these tears are a complication of shoulder dislocation is often unclear, as rotator cuff tears and glenohumeral instability interact. Reports on this combined injury pattern are rare, but based on the patient's age, activity level, and functional demand, therapeutic concepts have been devised. In active patients younger than 60 years and in cases of redislocation, both the rotator cuff tear and the capsule-labrum-ligament lesion should be reconstructed arthroscopically. In lesser active patients age 60 years or older, an isolated rotator cuff reconstruction is often sufficient to stabilize the glenohumeral joint. This treatment concept shows a predominantly good outcome.As a special form of anterior shoulder dislocation, a rotator cuff tear and a plexus brachialis lesion--the"terrible triad of the shoulder"--is described here.

  19. Evaporation-driven instability of the precorneal tear film.

    PubMed

    Peng, Cheng-Chun; Cerretani, Colin; Braun, Richard J; Radke, C J

    2014-04-01

    Tear-film instability is widely believed to be a signature of eye health. When an interblink is prolonged, randomly distributed ruptures occur in the tear film. "Black spots" and/or "black streaks" appear in 15 to 40 s for normal individuals. For people who suffer from dry eye, tear-film breakup time (BUT) is typically less than a few seconds. To date, however, there is no satisfactory quantitative explanation for the origin of tear rupture. Recently, it was proposed that tear-film breakup is related to locally high evaporative thinning. A spatial variation in the thickness of the tear-film lipid layer (TFLL) may lead to locally elevated evaporation and subsequent tear-film breakup. We examine the local-evaporation-driven tear-film-rupture hypothesis in a one-dimensional (1-D) model for the evolution of a thin aqueous tear film overriding the cornea subject to locally elevated evaporation at its anterior surface and osmotic water influx at its posterior surface. Evaporation rate depends on mass transfer both through the coating lipid layer and through ambient air. We establish that evaporation-driven tear-film breakup can occur under normal conditions but only for higher aqueous evaporation rates. Predicted roles of environmental conditions, such as wind speed and relative humidity, on tear-film stability agree with clinical observations. More importantly, locally elevated evaporation leads to hyperosmolar spots in the tear film and, hence, vulnerability to epithelial irritation. In addition to evaporation rate, tear-film instability depends on the strength of healing flow from the neighboring region outside the breakup region, which is determined by the surface tension at the tear-film surface and by the repulsive thin-film disjoining pressure. This study provides a physically consistent and quantitative explanation for the formation of black streaks and spots in the human tear film during an interblink. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Topical anaesthetic and tear film stability.

    PubMed

    Mengher, L S; Pandher, K S; Bron, A J

    1986-02-01

    The effect of unpreserved topical anaesthetic on tear film stability (0.4% oxybuprocaine hydrochloride) was investigated in a double masked randomised study in 12 healthy volunteers, using a noninvasive tear film break up technique (NIBUT). It was found that the topical anaesthetic did not reduce the pre-corneal tear film stability, contrary to the electron microscopic evidence.

  1. A low-angle detachment fault revealed: Three-dimensional images of the S-reflector fault zone along the Galicia passive margin

    NASA Astrophysics Data System (ADS)

    Schuba, C. Nur; Gray, Gary G.; Morgan, Julia K.; Sawyer, Dale S.; Shillington, Donna J.; Reston, Tim J.; Bull, Jonathan M.; Jordan, Brian E.

    2018-06-01

    A new 3-D seismic reflection volume over the Galicia margin continent-ocean transition zone provides an unprecedented view of the prominent S-reflector detachment fault that underlies the outer part of the margin. This volume images the fault's structure from breakaway to termination. The filtered time-structure map of the S-reflector shows coherent corrugations parallel to the expected paleo-extension directions with an average azimuth of 107°. These corrugations maintain their orientations, wavelengths and amplitudes where overlying faults sole into the S-reflector, suggesting that the parts of the detachment fault containing multiple crustal blocks may have slipped as discrete units during its late stages. Another interface above the S-reflector, here named S‧, is identified and interpreted as the upper boundary of the fault zone associated with the detachment fault. This layer, named the S-interval, thickens by tens of meters from SE to NW in the direction of transport. Localized thick accumulations also occur near overlying fault intersections, suggesting either non-uniform fault rock production, or redistribution of fault rock during slip. These observations have important implications for understanding how detachment faults form and evolve over time. 3-D seismic reflection imaging has enabled unique insights into fault slip history, fault rock production and redistribution.

  2. A bottom-driven mechanism for distributed faulting: Insights from the Gulf of California Rift

    NASA Astrophysics Data System (ADS)

    Persaud, P.; Tan, E.; Choi, E.; Contreras, J.; Lavier, L. L.

    2017-12-01

    The Gulf of California is a young oblique rift that displays a variation in rifting style along strike. Despite the rapid localization of strain in the Gulf at 6 Ma, the northern rift segment has the characteristics of a wide rift, with broadly distributed extensional strain and small gradients in topography and crustal thinning. Observations of active faulting in the continent-ocean transition of the Northern Gulf show multiple oblique-slip faults distributed in a 200 x 70 km2area developed some time after a westward relocation of the plate boundary at 2 Ma. In contrast, north and south of this broad pull-apart structure, major transform faults accommodate Pacific-North America plate motion. Here we propose that the mechanism for distributed brittle deformation results from the boundary conditions present in the Northern Gulf, where basal shear is distributed between the Cerro Prieto strike-slip fault (southernmost fault of the San Andreas fault system) and the Ballenas Transform fault. We hypothesize that in oblique-extensional settings whether deformation is partitioned in a few dip-slip and strike-slip faults, or in numerous oblique-slip faults may depend on (1) bottom-driven, distributed extension and shear deformation of the lower crust or upper mantle, and (2) the rift obliquity. To test this idea, we explore the effects of bottom-driven shear on the deformation of a brittle elastic-plastic layer with pseudo-three dimensional numerical models that include side forces. Strain localization results when the basal shear is a step-function while oblique-slip on numerous faults dominates when basal shear is distributed. We further investigate how the style of faulting varies with obliquity and demonstrate that the style of faulting observed in the Northern Gulf of California is reproduced in models with an obliquity of 0.7 and distributed basal shear boundary conditions, consistent with the interpreted obliquity and boundary conditions of the study area. Our

  3. Tsunamis and splay fault dynamics

    USGS Publications Warehouse

    Wendt, J.; Oglesby, D.D.; Geist, E.L.

    2009-01-01

    The geometry of a fault system can have significant effects on tsunami generation, but most tsunami models to date have not investigated the dynamic processes that determine which path rupture will take in a complex fault system. To gain insight into this problem, we use the 3D finite element method to model the dynamics of a plate boundary/splay fault system. We use the resulting ground deformation as a time-dependent boundary condition for a 2D shallow-water hydrodynamic tsunami calculation. We find that if me stress distribution is homogeneous, rupture remains on the plate boundary thrust. When a barrier is introduced along the strike of the plate boundary thrust, rupture propagates to the splay faults, and produces a significantly larger tsunami man in the homogeneous case. The results have implications for the dynamics of megathrust earthquakes, and also suggest mat dynamic earthquake modeling may be a useful tool in tsunami researcn. Copyright 2009 by the American Geophysical Union.

  4. The relationship of near-surface active faulting to megathrust splay fault geometry in Prince William Sound, Alaska

    NASA Astrophysics Data System (ADS)

    Finn, S.; Liberty, L. M.; Haeussler, P. J.; Northrup, C.; Pratt, T. L.

    2010-12-01

    We interpret regionally extensive, active faults beneath Prince William Sound (PWS), Alaska, to be structurally linked to deeper megathrust splay faults, such as the one that ruptured in the 1964 M9.2 earthquake. Western PWS in particular is unique; the locations of active faulting offer insights into the transition at the southern terminus of the previously subducted Yakutat slab to Pacific plate subduction. Newly acquired high-resolution, marine seismic data show three seismic facies related to Holocene and older Quaternary to Tertiary strata. These sediments are cut by numerous high angle normal faults in the hanging wall of megathrust splay. Crustal-scale seismic reflection profiles show splay faults emerging from 20 km depth between the Yakutat block and North American crust and surfacing as the Hanning Bay and Patton Bay faults. A distinct boundary coinciding beneath the Hinchinbrook Entrance causes a systematic fault trend change from N30E in southwestern PWS to N70E in northeastern PWS. The fault trend change underneath Hinchinbrook Entrance may occur gradually or abruptly and there is evidence for similar deformation near the Montague Strait Entrance. Landward of surface expressions of the splay fault, we observe subsidence, faulting, and landslides that record deformation associated with the 1964 and older megathrust earthquakes. Surface exposures of Tertiary rocks throughout PWS along with new apatite-helium dates suggest long-term and regional uplift with localized, fault-controlled subsidence.

  5. A wideband magnetoresistive sensor for monitoring dynamic fault slip in laboratory fault friction experiments

    USGS Publications Warehouse

    Kilgore, Brian D.

    2017-01-01

    A non-contact, wideband method of sensing dynamic fault slip in laboratory geophysical experiments employs an inexpensive magnetoresistive sensor, a small neodymium rare earth magnet, and user built application-specific wideband signal conditioning. The magnetoresistive sensor generates a voltage proportional to the changing angles of magnetic flux lines, generated by differential motion or rotation of the near-by magnet, through the sensor. The performance of an array of these sensors compares favorably to other conventional position sensing methods employed at multiple locations along a 2 m long × 0.4 m deep laboratory strike-slip fault. For these magnetoresistive sensors, the lack of resonance signals commonly encountered with cantilever-type position sensor mounting, the wide band response (DC to ≈ 100 kHz) that exceeds the capabilities of many traditional position sensors, and the small space required on the sample, make them attractive options for capturing high speed fault slip measurements in these laboratory experiments. An unanticipated observation of this study is the apparent sensitivity of this sensor to high frequency electomagnetic signals associated with fault rupture and (or) rupture propagation, which may offer new insights into the physics of earthquake faulting.

  6. Increased Tear Film Osmolarity in Systemic Lupus Erythematosus.

    PubMed

    Duru, Necati; Altinkaynak, Hasan; Uysal, Betul Seher; Duru, Zeynep; Can, Mehmet Erol; Erten, Sukran; Yuksel, Nilay; Kalkan Akcay, Emine

    2017-01-01

    To evaluate tear film osmolarity in patients with systemic lupus erythematosus (SLE). A total of 55 eyes from 55 patients with SLE and 47 eyes from 47 age- and gender-matched healthy individuals were included in this study. Tear film osmolarity was evaluated with a lab-on-a-chip technique (TearLab; TearLab Corporation, San Diego, CA) in SLE patients in comparison with healthy individuals, and results were correlated to clinically available diagnostic tests for dry eye, such as tear film break-up time (BUT), Schirmer's test, and Ocular Surface Disease Index (OSDI). The mean tear film osmolarity in the SLE patients and healthy individuals was 306.02 ± 13.27 mOsm/L and 300.74 ± 9.11 mOsm/L, respectively, which made for a statistically significant difference (p = 0.020). In the SLE group, tear film osmolarity was negatively correlated with the Schirmer's test score and the BUT value (r = -0.295 p = 0.029 and r = 0.347 p = 0.009, respectively), whereas tear film osmolarity was not correlated with OSDI score (r = -0.182 p = 0.183). This study revealed that tear film hyperosmolarity and abnormal tear film function are associated with SLE.

  7. Glenohumeral Instability Related to Special Conditions: SLAP Tears, Pan-labral Tears, and Multidirectional Instability.

    PubMed

    Van Blarcum, Gregory S; Svoboda, Steven J

    2017-09-01

    Glenohumeral instability is one of the more common conditions seen by sports medicine physicians, especially in young, active athletes. The associated anatomy of the glenohumeral joint (the shallow nature of the glenoid and the increased motion it allows) make the shoulder more prone to instability events as compared with other joints. Although traumatic dislocations or instability events associated with acute labral tears (ie, Bankart lesions) are well described in the literature, there exists other special shoulder conditions that are also associated with shoulder instability: superior labrum anterior/posterior (SLAP) tears, pan-labral tears, and multidirectional instability. SLAP tears can be difficult to diagnose and arthroscopic diagnosis remains the gold standard. Surgical treatment as ranged from repair to biceps tenodesis with varying reports of success. Along the spectrum of SLAP tears, pan-labral tears consist of 360-degree injuries to the labrum. Patients can present complaining of either anterior or posterior instability alone, making the physical examination and advanced imaging a crucial component of the work up of the patients. Arthroscopic labral repair remains a good initial option for surgical treatment of these conditions. Multidirectional instability remains one of the more difficult conditions for the sports medicine physician to diagnose and treat. Symptoms may only be reported as vague pain versus frank instability making the diagnoses particularly challenging, especially in a patient with overall joint laxity. Conservative management to include physical therapy is the mainstay initial treatment in patients without an identifiable structural abnormality. Surgical management of this condition has evolved from open to arthroscopic capsular shifts with comparable results.

  8. Tear gas: an epidemiological and mechanistic reassessment

    PubMed Central

    Rothenberg, Craig; Achanta, Satyanarayana; Svendsen, Erik R.

    2016-01-01

    Deployments of tear gas and pepper spray have rapidly increased worldwide. Large amounts of tear gas have been used in densely populated cities, including Cairo, Istanbul, Rio de Janeiro, Manama (Bahrain), and Hong Kong. In the United States, tear gas was used extensively during recent riots in Ferguson, Missouri. Whereas tear gas deployment systems have rapidly improved—with aerial drone systems tested and requested by law enforcement—epidemiological and mechanistic research have lagged behind and have received little attention. Case studies and recent epidemiological studies revealed that tear gas agents can cause lung, cutaneous, and ocular injuries, with individuals affected by chronic morbidities at high risk for complications. Mechanistic studies identified the ion channels TRPV1 and TRPA1 as targets of capsaicin in pepper spray, and of the tear gas agents chloroacetophenone, CS, and CR. TRPV1 and TRPA1 localize to pain‐sensing peripheral sensory neurons and have been linked to acute and chronic pain, cough, asthma, lung injury, dermatitis, itch, and neurodegeneration. In animal models, transient receptor potential inhibitors show promising effects as potential countermeasures against tear gas injuries. On the basis of the available data, a reassessment of the health risks of tear gas exposures in the civilian population is advised, and development of new countermeasures is proposed. PMID:27391380

  9. Identifiability of Additive, Time-Varying Actuator and Sensor Faults by State Augmentation

    NASA Technical Reports Server (NTRS)

    Upchurch, Jason M.; Gonzalez, Oscar R.; Joshi, Suresh M.

    2014-01-01

    Recent work has provided a set of necessary and sucient conditions for identifiability of additive step faults (e.g., lock-in-place actuator faults, constant bias in the sensors) using state augmentation. This paper extends these results to an important class of faults which may affect linear, time-invariant systems. In particular, the faults under consideration are those which vary with time and affect the system dynamics additively. Such faults may manifest themselves in aircraft as, for example, control surface oscillations, control surface runaway, and sensor drift. The set of necessary and sucient conditions presented in this paper are general, and apply when a class of time-varying faults affects arbitrary combinations of actuators and sensors. The results in the main theorems are illustrated by two case studies, which provide some insight into how the conditions may be used to check the theoretical identifiability of fault configurations of interest for a given system. It is shown that while state augmentation can be used to identify certain fault configurations, other fault configurations are theoretically impossible to identify using state augmentation, giving practitioners valuable insight into such situations. That is, the limitations of state augmentation for a given system and configuration of faults are made explicit. Another limitation of model-based methods is that there can be large numbers of fault configurations, thus making identification of all possible configurations impractical. However, the theoretical identifiability of known, credible fault configurations can be tested using the theorems presented in this paper, which can then assist the efforts of fault identification practitioners.

  10. The evolving contribution of border faults and intra-rift faults in early-stage East African rifts: insights from the Natron (Tanzania) and Magadi (Kenya) basins

    NASA Astrophysics Data System (ADS)

    Muirhead, J.; Kattenhorn, S. A.; Dindi, E.; Gama, R.

    2013-12-01

    In the early stages of continental rifting, East African Rift (EAR) basins are conventionally depicted as asymmetric basins bounded on one side by a ~100 km-long border fault. As rifting progresses, strain concentrates into the rift center, producing intra-rift faults. The timing and nature of the transition from border fault to intra-rift-dominated strain accommodation is unclear. Our study focuses on this transitional phase of continental rifting by exploring the spatial and temporal evolution of faulting in the Natron (border fault initiation at ~3 Ma) and Magadi (~7 Ma) basins of northern Tanzania and southern Kenya, respectively. We compare the morphologies and activity histories of faults in each basin using field observations and remote sensing in order to address the relative contributions of border faults and intra-rift faults to crustal strain accommodation as rifting progresses. The ~500 m-high border fault along the western margin of the Natron basin is steep compared to many border faults in the eastern branch of the EAR, indicating limited scarp degradation by mass wasting. Locally, the escarpment shows open fissures and young scarps 10s of meters high and a few kilometers long, implying ongoing border fault activity in this young rift. However, intra-rift faults within ~1 Ma lavas are greatly eroded and fresh scarps are typically absent, implying long recurrence intervals between slip events. Rift-normal topographic profiles across the Natron basin show the lowest elevations in the lake-filled basin adjacent to the border fault, where a number of hydrothermal springs along the border fault system expel water into the lake. In contrast to Natron, a ~1600 m high, densely vegetated, border fault escarpment along the western edge of the Magadi basin is highly degraded; we were unable to identify evidence of recent rupturing. Rift-normal elevation profiles indicate the focus of strain has migrated away from the border fault into the rift center, where

  11. The determination of the stacking fault energy in copper-nickel alloys

    NASA Technical Reports Server (NTRS)

    Leighly, H. P., Jr.

    1982-01-01

    Methods for determining the stacking fault energies of a series of nickel-copper alloys to gain an insight into the embrittling effect of hydrogen are evaluated. Plans for employing weak beam dark field electron microscopy to determine stacking fault energies are outlined.

  12. Posterior Displacement of Supraspinatus Central Tendon Observed on Magnetic Resonance Imaging: A Useful Preoperative Indicator of Rotator Cuff Tear Characteristics.

    PubMed

    Updegrove, Gary F; Armstrong, April D; Mosher, Timothy J; Kim, H Mike

    2015-11-01

    To characterize the orientation of the normal supraspinatus central tendon and describe the displacement patterns of the central tendon in rotator cuff tears using a magnetic resonance imaging (MRI)-based method. We performed a retrospective MRI and chart review of 183 patients with a rotator cuff tear (cuff tear group), 52 with a labral tear but no rotator cuff tear (labral tear group), and 74 with a normal shoulder (normal group). The orientation of the supraspinatus central tendon relative to the bicipital groove was evaluated based on axial MRI and was numerically represented by the shortest distance from the lateral extension line of the central tendon to the bicipital groove. Tear size, fatty degeneration, and involvement of the anterior supraspinatus were evaluated to identify the factors associated with orientation changes. The mean distance from the bicipital groove to the central tendon line was 0.7 mm and 1.3 mm in the normal group and labral tear group, respectively. Full-thickness cuff tears involving the anterior supraspinatus showed a significantly greater distance (17.7 mm) than those sparing the anterior supraspinatus (4.9 mm, P = .001). Fatty degeneration of the supraspinatus was significantly correlated with the distance (P = .006). Disruption of the anterior supraspinatus and fatty degeneration of the supraspinatus were independent predictors of posterior displacement. The supraspinatus central tendon has a constant orientation toward the bicipital groove in normal shoulders, and the central tendon is frequently displaced posteriorly in full-thickness rotator cuff tears involving the anterior leading edge of the supraspinatus. The degree of posterior displacement is proportional to tear size and severity of fatty degeneration of the supraspinatus muscle. A simple and quick assessment of the central tendon orientation on preoperative MRI can be a useful indicator of tear characteristics, potentially providing insight into the intraoperative

  13. Tear and decohesion of bovine pericardial tissue.

    PubMed

    Tobaruela, Almudena; Elices, Manuel; Bourges, Jean Yves; Rojo, Francisco Javier; Atienza, José Miguel; Guinea, Gustavo

    2016-10-01

    The aim of this study was to evaluate quantitatively the fracture-by tear and delamination-of bovine pericardium tissues which are usually employed for the manufacture of bioprosthetic valves. A large number of samples (77) were tested in root-to-apex and circumferential directions, according to a standardised tear test (ASTM D 1938). Before performing the tear test, some samples were subjected to 1000 cycles of fatigue to a maximum stress of 3MPa. Fracture toughness of tearing and delamination were computed by following a simple fracture model. The study showed significantly lower values of delamination toughness compared with tear delamination. Moreover, tear forces were different in each test direction, revealing a clear orthotropic behaviour. All these results, as well as the testing procedure, could be of value for future research in the physiological function of pericardium tissues and clinical applications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. The Maradi fault zone: 3-D imagery of a classic wrench fault in Oman

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neuhaus, D.

    1993-09-01

    The Maradi fault zone extends for almost 350 km in a north-northwest-south-southeast direction from the Oman Mountain foothills into the Arabian Sea, thereby dissecting two prolific hydrocarbon provinces, the Ghaba and Fahud salt basins. During its major Late Cretaceous period of movement, the Maradi fault zone acted as a left-lateral wrench fault. An early exploration campaign based on two-dimensional seismic targeted at fractured Cretaceous carbonates had mixed success and resulted in the discovery of one producing oil field. The structural complexity, rapidly varying carbonate facies, and uncertain fracture distribution prevented further drilling activity. In 1990 a three-dimensional (3-D) seismic surveymore » covering some 500 km[sup 2] was acquired over the transpressional northern part of the Maradi fault zone. The good data quality and the focusing power of 3-D has enabled stunning insight into the complex structural style of a [open quotes]textbook[close quotes] wrench fault, even at deeper levels and below reverse faults hitherto unexplored. Subtle thickness changes within the carbonate reservoir and the unconformably overlying shale seal provided the tool for the identification of possible shoals and depocenters. Horizon attribute maps revealed in detail the various structural components of the wrench assemblage and highlighted areas of increased small-scale faulting/fracturing. The results of four recent exploration wells will be demonstrated and their impact on the interpretation discussed.« less

  15. New insights into the tectonic evolution of the Boconó Fault, Mérida Andes, Venezuela

    NASA Astrophysics Data System (ADS)

    Backé, G.

    2006-12-01

    The Boconó fault is a major right-lateral strike-slip fault that cuts along strike the Mérida Andes in Venezuela. The uplift of this mountain range started in the Miocene as a consequence of the relative oblique convergence between two lithospheric units named the Maracaibo block to the northwest and the Guyana shield to the southeast. Deformation in the Mérida Andes is partitioned between a strike-slip component along the Boconó fault and shortening perpendicular to the belt. Distinctive features define the Boconó fault: it is shifted southward relative to the chain axis and it does not have a continuous and linear trace but is composed of several fault segments of different orientations striking N35°E to N65°E. Quaternary fault strike-slip motion has been evidenced by various independent studies. However, onset of the strike-slip motion, fault offset and geometry at depth remains a matter of debate. Our work, based on morphostructural analyses of satellite and digital elevation model imagery, provides new data on both the geometry and the tectonic evolution of this major structure. We argue that the Boconó fault affects only the upper crust and connects at depth to a décollement. Consequently, it can not be considered as a plate boundary. The Boconó fault does however form the boundary between two different tectonic areas in the central part of the Mérida Andes as revealed by the earthquake focal mechanisms. South of the Boconó fault, the focal mechanisms are mainly compressional and reverse oblique-slip in agreement with NW SE shortening in the foothills. North of the Boconó fault, extensional and strike-slip deformation dominates. Microtectonic measurements collected in the central part of the Boconó fault are characterized by polyphased tectonics. The dextral shearing along the fault is superimposed to reverse oblique-slip to reverse motion, showing that initiation of transcurrent movement is more likely to have occurred after a certain amount of

  16. Seismic variability of subduction thrust faults: Insights from laboratory models

    NASA Astrophysics Data System (ADS)

    Corbi, F.; Funiciello, F.; Faccenna, C.; Ranalli, G.; Heuret, A.

    2011-06-01

    Laboratory models are realized to investigate the role of interface roughness, driving rate, and pressure on friction dynamics. The setup consists of a gelatin block driven at constant velocity over sand paper. The interface roughness is quantified in terms of amplitude and wavelength of protrusions, jointly expressed by a reference roughness parameter obtained by their product. Frictional behavior shows a systematic dependence on system parameters. Both stick slip and stable sliding occur, depending on driving rate and interface roughness. Stress drop and frequency of slip episodes vary directly and inversely, respectively, with the reference roughness parameter, reflecting the fundamental role for the amplitude of protrusions. An increase in pressure tends to favor stick slip. Static friction is a steeply decreasing function of the reference roughness parameter. The velocity strengthening/weakening parameter in the state- and rate-dependent dynamic friction law becomes negative for specific values of the reference roughness parameter which are intermediate with respect to the explored range. Despite the simplifications of the adopted setup, which does not address the problem of off-fault fracturing, a comparison of the experimental results with the depth distribution of seismic energy release along subduction thrust faults leads to the hypothesis that their behavior is primarily controlled by the depth- and time-dependent distribution of protrusions. A rough subduction fault at shallow depths, unable to produce significant seismicity because of low lithostatic pressure, evolves into a moderately rough, velocity-weakening fault at intermediate depths. The magnitude of events in this range is calibrated by the interplay between surface roughness and subduction rate. At larger depths, the roughness further decreases and stable sliding becomes gradually more predominant. Thus, although interplate seismicity is ultimately controlled by tectonic parameters (velocity of

  17. Evaluating tear clearance rate with optical coherence tomography.

    PubMed

    Garaszczuk, Izabela K; Mousavi, Maryam; Cervino Exposito, Alejandro; Bartuzel, Maciej M; Montes-Micó, Robert; Iskander, D Robert

    2018-02-01

    To assess the early-phase of tear clearance rate (TCR) with anterior segment optical coherence tomography (OCT) and to determine the association between TCR and other clinical measures of the tear film in a group of young subjects with different levels of tear film quality. TCR was classified as the percentage decrease of subject's inferior tear meniscus height 30s after instillation of 5μl 0.9% saline solution. Fifty subjects (32F and 18M) aged (mean±standard deviation) 25.5±4.3 years volunteered for the study. It consisted of a review of medical history, Ocular Surface Disease Index (OSDI) questionnaire, tear film osmolarity measurements, slit lamp examination and TCR estimation based on dynamic measurements of the lower tear meniscus with OCT. Estimates of TCR were contrasted against subject age and tear film measures commonly used for dry eye diagnosis, which includes OSDI score, fluorescein tear film break-up time (FBUT), tear meniscus height (TMH), blinking frequency, tear film osmolarity and corneal staining. The group mean TCR was 29±13% and 36±19% respectively after 30 and 60s margin after saline solution instillation. Statistically significant correlations were found between TCR and FBUT (r 2 =0.319, p<0.001), blinking frequency (r 2 =0.138, p<0.01), tear film osmolarity (r 2 =0.133, p<0.01) and subject's age (r 2 =0.095, p<0.05). Anterior segment optical coherence tomography allows following changes of tear meniscus morphology post saline solution instillation and evaluating the TCR. OCT based TCR might be used as additional measure of the lacrimal functional unit. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  18. Mountain building, strike-slip faulting, and landscape evolution in the Marlborough Fault System, NZ: Insights from new low-temperature thermochronology and modeling

    NASA Astrophysics Data System (ADS)

    Duvall, A. R.; Collett, C.; Flowers, R. M.; Tucker, G. E.; Upton, P.

    2016-12-01

    The 150 km wide Marlborough Fault System (MFS) and adjacent dextral-reverse Alpine Fault accommodate oblique convergence of the Australian and Pacific plates in a broad transform boundary that extends for much of the South Island New Zealand. Understanding the deformation history of the Marlborough region offers the opportunity to study topographic evolution in a strike-slip setting and a fuller picture of the evolving New Zealand plate boundary as the MFS lies at the transition from oceanic Pacific plate subduction to oblique continental collision. Here we present low-temperature thermochronology from the MFS to place new limits on the timing and style of mountain building. We sampled a range of elevations spanning 2 km within and adjacent to the Kaikoura Mountains, which stand high as topographic anomalies above active strike-slip faults. Young apatite (U-Th)/He ages ( 2-5 Ma) on both sides of range-bounding faults are consistent with regional distributed deformation since the Pliocene initiation of strike-slip faulting. However, large differences in both zircon helium and apatite fission track ages, from Paleogene/Neogene ages within hanging walls to unreset >100 Ma ages in footwalls, indicate an early phase of fault-related vertical exhumation. Thermal modeling using the QTQt program reveals two phases of exhumation within the Kaikoura Ranges: rapid cooling at 15-12 Ma localized to hanging wall rocks and regional rapid cooling reflected in all samples starting at 4-5 Ma. These results and landscape evolution models suggest that, despite the presence of active mountain front faults, much of the topographic relief in this region may predate the onset of strike-slip faulting and that portions of the Marlborough Faults are re-activated thrusts that coincide with the early development of the transpressive plate boundary. Regional exhumation after 5 Ma likely reflects increased proximity to the migrating Pacific plate subduction zone and the buoyant Chatham Rise.

  19. Hot Tearing in Aluminium — Copper Alloys

    NASA Astrophysics Data System (ADS)

    Viano, David; StJohn, David; Grandfield, John; Cáceres, Carlos

    For many aluminium alloys, hot tearing susceptibility follows a lambda curve relationship when hot tearing severity is plotted as a function of solute content. In the past, there has been some difficulty quantifying hot tearing. Traditional methods rely upon measuring electrical resistivity or the number and/or length of cracks in tests such as the ring test. In this experimental program, a hot tear test rig was used to investigate a series of binary Al-Cu alloys. This device measures the load imposed on the mushy zone during solidification. Hot tearing susceptibility was quantified in two ways. The first method involved measuring the load at the solidus temperature (548°C). The second method was to radiograph the hot spot and measure the image density of the cracks. Both methods had advantages and disadvantages. It was found that the results from the hot tear rig correlates with other published data using different experimental methods.

  20. Chemosignalling effects of human tears revisited: Does exposure to female tears decrease males' perception of female sexual attractiveness?

    PubMed

    Gračanin, Asmir; van Assen, Marcel A L M; Omrčen, Višnja; Koraj, Ivana; Vingerhoets, Ad J J M

    2017-01-01

    Gelstein et al. reported the results of three experiments suggesting a dampening influence of inhalation of female emotional tears on males' arousal and perception of female sexual attractiveness, specifically in non-sexual situations. This prompted the hypothesis that crying exerts its influence on others not only via the auditory and visual mode but also via chemosignals. In three studies, we attempted to replicate and extend Gelstein et al.'s findings by including an additional condition with irritant tears, by using pictures of sexually attractive women, and by testing related hypotheses on the pro-social effects of exposure to tears. All three studies, separately or combined in a meta-analysis, failed to replicate the original inhibitory effects of tears. In addition, sniffing tears did not affect measures of connectedness, aggression and pro-social behaviour. It is concluded that the effects of female tears on male arousal and perception of female sexual attractiveness, if any, are very weak at best. Rather, it seems that crying exerts its strong inter-personal effects through the visual and auditory sensory channels.

  1. 49 CFR 173.340 - Tear gas devices.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Tear gas devices. 173.340 Section 173.340... SHIPMENTS AND PACKAGINGS Gases; Preparation and Packaging § 173.340 Tear gas devices. (a) Packagings for tear gas devices must be approved prior to initial transportation by the Associate Administrator. (b...

  2. Tear clearance implications for ocular surface health.

    PubMed

    de Paiva, Cintia Sade; Pflugfelder, Stephen C

    2004-03-01

    Tear clearance/turnover provides a global assessment of the function of the lacrimal functional unit and of tear exchange on the ocular surface. It is an indirect measure of dry eye induced inflammation on the ocular surface. It shows better correlation with the severity of ocular irritation symptoms and corneal epithelial disease in dry eye than the Schirmer 1 test. Delayed tear clearance may prove to be the best measure for identifying patients with tear film disorders who may respond to anti-inflammatory therapy.

  3. Tear Film Osmolarity in Subjects with Acute Allergic Rhinoconjunctivitis

    PubMed Central

    NITODA, EIRINI; LAVARIS, ANASTASIOS; LAIOS, KONSTANTINOS; ANDROUDI, SOPHIA; KALOGEROPOULOS, CHRIS D; TSATSOS, MICHAEL; DAMASKOS, CHRISTOS; GARMPIS, NIKOLAOS; MOSCHOS, MARILITA M

    2018-01-01

    Background/Aim: Acute allergic rhinoconjuctivitis is the most common form of ocular allergies. The pathogenetic mechanisms are based on an immunoglobulin E (IgE)-mediated hypersensitivity reaction. On the other hand, tear osmolarity has been suggested to be an index of ocular surface damage and inflammation. These data were the motive to investigate the levels of tear osmolarity in subjects with acute allergic rhinoconjuctivitis, before and after administration of artificial tears. Patients and Methods: Forty-five subjects with acute allergic rhinoconjuctivitis were randomly divided into three groups, based on the type of artificial tears that they received: Group A (Thera tears), Group B (Wet therapy) and Group C (Tears Naturale free). The eye drops were administered six times a day for 60 days and all subjects underwent grading of subjective symptoms and clinical examination at baseline and at the end of the treatment. Results: The diagnosis of severe eye disease, which was based on ocular surface disease index (OSDI; Allergan, Inc, Irvine, CA, USA) and tear osmolarity values, concerned all patients at baseline. Although the administration of artificial tears significantly ameliorated the symptoms and the ocular variables in all groups, the results were better in the first group. Tear osmolarity was strongly and negatively correlated with tear film breakup time (BUT) and Schirmer I test at 2 months. Contrariwise, symptoms were eliminated, when tear osmolarity was decreased. Conclusion: Acute allergic rhinoconjuctivitis is characterized by tear hyperosmolarity, which can be rehabilitated with the administration of hypotonic artificial tears. PMID:29475928

  4. Tear Film Osmolarity in Subjects with Acute Allergic Rhinoconjunctivitis.

    PubMed

    Nitoda, Eirini; Lavaris, Anastasios; Laios, Konstantinos; Androudi, Sophia; Kalogeropoulos, Chris D; Tsatsos, Michael; Damaskos, Christos; Garmpis, Nikolaos; Moschos, Marilita M

    2018-01-01

    Acute allergic rhinoconjuctivitis is the most common form of ocular allergies. The pathogenetic mechanisms are based on an immunoglobulin E (IgE)-mediated hypersensitivity reaction. On the other hand, tear osmolarity has been suggested to be an index of ocular surface damage and inflammation. These data were the motive to investigate the levels of tear osmolarity in subjects with acute allergic rhinoconjuctivitis, before and after administration of artificial tears. Forty-five subjects with acute allergic rhinoconjuctivitis were randomly divided into three groups, based on the type of artificial tears that they received: Group A (Thera tears), Group B (Wet therapy) and Group C (Tears Naturale free). The eye drops were administered six times a day for 60 days and all subjects underwent grading of subjective symptoms and clinical examination at baseline and at the end of the treatment. The diagnosis of severe eye disease, which was based on ocular surface disease index (OSDI; Allergan, Inc, Irvine, CA, USA) and tear osmolarity values, concerned all patients at baseline. Although the administration of artificial tears significantly ameliorated the symptoms and the ocular variables in all groups, the results were better in the first group. Tear osmolarity was strongly and negatively correlated with tear film breakup time (BUT) and Schirmer I test at 2 months. Contrariwise, symptoms were eliminated, when tear osmolarity was decreased. Acute allergic rhinoconjuctivitis is characterized by tear hyperosmolarity, which can be rehabilitated with the administration of hypotonic artificial tears. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  5. "3D_Fault_Offsets," a Matlab Code to Automatically Measure Lateral and Vertical Fault Offsets in Topographic Data: Application to San Andreas, Owens Valley, and Hope Faults

    NASA Astrophysics Data System (ADS)

    Stewart, N.; Gaudemer, Y.; Manighetti, I.; Serreau, L.; Vincendeau, A.; Dominguez, S.; Mattéo, L.; Malavieille, J.

    2018-01-01

    Measuring fault offsets preserved at the ground surface is of primary importance to recover earthquake and long-term slip distributions and understand fault mechanics. The recent explosion of high-resolution topographic data, such as Lidar and photogrammetric digital elevation models, offers an unprecedented opportunity to measure dense collections of fault offsets. We have developed a new Matlab code, 3D_Fault_Offsets, to automate these measurements. In topographic data, 3D_Fault_Offsets mathematically identifies and represents nine of the most prominent geometric characteristics of common sublinear markers along faults (especially strike slip) in 3-D, such as the streambed (minimum elevation), top, free face and base of channel banks or scarps (minimum Laplacian, maximum gradient, and maximum Laplacian), and ridges (maximum elevation). By calculating best fit lines through the nine point clouds on either side of the fault, the code computes the lateral and vertical offsets between the piercing points of these lines onto the fault plane, providing nine lateral and nine vertical offset measures per marker. Through a Monte Carlo approach, the code calculates the total uncertainty on each offset. It then provides tools to statistically analyze the dense collection of measures and to reconstruct the prefaulted marker geometry in the horizontal and vertical planes. We applied 3D_Fault_Offsets to remeasure previously published offsets across 88 markers on the San Andreas, Owens Valley, and Hope faults. We obtained 5,454 lateral and vertical offset measures. These automatic measures compare well to prior ones, field and remote, while their rich record provides new insights on the preservation of fault displacements in the morphology.

  6. Potential earthquake faults offshore Southern California, from the eastern Santa Barbara Channel south to Dana Point

    USGS Publications Warehouse

    Fisher, M.A.; Sorlien, C.C.; Sliter, R.W.

    2009-01-01

    Urban areas in Southern California are at risk from major earthquakes, not only quakes generated by long-recognized onshore faults but also ones that occur along poorly understood offshore faults. We summarize recent research findings concerning these lesser known faults. Research by the U.S. Geological Survey during the past five years indicates that these faults from the eastern Santa Barbara Channel south to Dana Point pose a potential earthquake threat. Historical seismicity in this area indicates that, in general, offshore faults can unleash earthquakes having at least moderate (M 5-6) magnitude. Estimating the earthquake hazard in Southern California is complicated by strain partitioning and by inheritance of structures from early tectonic episodes. The three main episodes are Mesozoic through early Miocene subduction, early Miocene crustal extension coeval with rotation of the Western Transverse Ranges, and Pliocene and younger transpression related to plate-boundary motion along the San Andreas Fault. Additional complication in the analysis of earthquake hazards derives from the partitioning of tectonic strain into strike-slip and thrust components along separate but kinematically related faults. The eastern Santa Barbara Basin is deformed by large active reverse and thrust faults, and this area appears to be underlain regionally by the north-dipping Channel Islands thrust fault. These faults could produce moderate to strong earthquakes and destructive tsunamis. On the Malibu coast, earthquakes along offshore faults could have left-lateral-oblique focal mechanisms, and the Santa Monica Mountains thrust fault, which underlies the oblique faults, could give rise to large (M ??7) earthquakes. Offshore faults near Santa Monica Bay and the San Pedro shelf are likely to produce both strike-slip and thrust earthquakes along northwest-striking faults. In all areas, transverse structures, such as lateral ramps and tear faults, which crosscut the main faults, could

  7. Surgical Treatment of Combined Posterior Root Tears of the Lateral Meniscus and ACL Tears

    PubMed Central

    Pan, Fengyu; Hua, Shan; Ma, Zhuang

    2015-01-01

    Background The treatment of anterior cruciate ligament (ACL) rupture complicated with posterior lateral meniscus root (PLMR) tears remains controversial. The goal of this study was to evaluate clinical outcomes of PLMR tear refixation versus left untreated at the time of reconstruction. Material/Methods From August 2001 to January 2012, 31 patients who undergone repair of PLMR tears were evaluated and compared with a matched control group with untreated PLMR tears. Clinical evaluation consisted of the Lysholm scale, subjective International Knee Documentation Committee (IKDC) questionnaires, and radiographic evaluation with MRI. Results Regarding to the Lysholm score and the subjective questionnaire score, there were no statistical difference between the 2 groups. However, patients after operative treatment reach higher functional scores and lower rates of osteoarthritis (normal: group A, 80%, and group B, 48%, respectively) with statistical significance (P<0.05) compared to the matched control group. Conclusions Surgical and conservative treatment of the PLMR can both effectively improve knee function. However, a tendency towards higher functional scores and lower rates of osteoarthritis for patients with operative treatment was observed. PMID:25959903

  8. Structure of the eastern Seattle fault zone, Washington state: New insights from seismic reflection data

    USGS Publications Warehouse

    Liberty, L.M.; Pratt, T.L.

    2008-01-01

    We identify and characterize the active Seattle fault zone (SFZ) east of Lake Washington with newly acquired seismic reflection data. Our results focus on structures observed in the upper 1 km below the cities of Bellevue, Sammamish, Newcastle, and Fall City, Washington. The SFZ appears as a broad zone of faulting and folding at the southern boundary of the Seattle basin and north edge of the Seattle uplift. We interpret the Seattle fault as a thrust fault that accommodates north-south shortening by forming a fault-propagation fold with a forelimb breakthrough. The blind tip of the main fault forms a synclinal growth fold (deformation front) that extends at least 8 km east of Vasa Park (west side of Lake Sammamish) and defines the south edge of the Seattle basin. South of the deformation front is the forelimb break-through fault, which was exposed in a trench at Vasa Park. The Newcastle Hills anticline, a broad anticline forming the north part of the Seattle uplift east of Lake Washington, is interpreted to lie between the main blind strand of the Seattle fault and a backthrust. Our profiles, on the northern limb of this anticline, consistently image north-dipping strata. A structural model for the SFZ east of Lake Washington is consistent with about 8 km of slip on the upper part of the Seattle fault, but the amount of motion is only loosely constrained.

  9. The role of thin, mechanical discontinuities on the propagation of reverse faults: insights from analogue models

    NASA Astrophysics Data System (ADS)

    Bonanno, Emanuele; Bonini, Lorenzo; Basili, Roberto; Toscani, Giovanni; Seno, Silvio

    2016-04-01

    Fault-related folding kinematic models are widely used to explain accommodation of crustal shortening. These models, however, include simplifications, such as the assumption of constant growth rate of faults. This value sometimes is not constant in isotropic materials, and even more variable if one considers naturally anisotropic geological systems. , This means that these simplifications could lead to incorrect interpretations of the reality. In this study, we use analogue models to evaluate how thin, mechanical discontinuities, such as beddings or thin weak layers, influence the propagation of reverse faults and related folds. The experiments are performed with two different settings to simulate initially-blind master faults dipping at 30° and 45°. The 30° dip represents one of the Andersonian conjugate fault, and 45° dip is very frequent in positive reactivation of normal faults. The experimental apparatus consists of a clay layer placed above two plates: one plate, the footwall, is fixed; the other one, the hanging wall, is mobile. Motor-controlled sliding of the hanging wall plate along an inclined plane reproduces the reverse fault movement. We run thirty-six experiments: eighteen with dip of 30° and eighteen with dip of 45°. For each dip-angle setting, we initially run isotropic experiments that serve as a reference. Then, we run the other experiments with one or two discontinuities (horizontal precuts performed into the clay layer). We monitored the experiments collecting side photographs every 1.0 mm of displacement of the master fault. These images have been analyzed through PIVlab software, a tool based on the Digital Image Correlation method. With the "displacement field analysis" (one of the PIVlab tools) we evaluated, the variation of the trishear zone shape and how the master-fault tip and newly-formed faults propagate into the clay medium. With the "strain distribution analysis", we observed the amount of the on-fault and off-fault deformation

  10. On the tear resistance of skin

    DOE PAGES

    Yang, Wen; Sherman, Vincent R.; Gludovatz, Bernd; ...

    2015-03-27

    Tear resistance is vitally important for the various functions of skin, especially protection from predatorial attack. Here, we mechanistically quantify the extreme tear resistance of skin and identify the underlying structural features, which lead to its sophisticated failure mechanisms. Here we explain why it is virtually impossible to propagate a tear in rabbit skin, chosen as a model material for the dermis of vertebrates. Finally, we express the deformation in terms of four mechanisms of collagen fibril activity in skin under tensile loading that virtually eliminate the possibility of tearing in pre-notched samples: fibril straightening, fibril reorientation towards the tensilemore » direction, elastic stretching and interfibrillar sliding, all of which contribute to the redistribution of the stresses at the notch tip.« less

  11. Diadenosine tetraphosphate contributes to carbachol-induced tear secretion.

    PubMed

    Fonseca, Begoña; Martínez-Águila, Alejandro; Díaz-Hernández, Miguel; Pintor, Jesús

    2015-03-01

    The purpose of this study is to investigate if the cholinergic stimulation by carbachol on tear secretion is a direct process or if it is also mediated by purinergic mechanisms. Experiments were performed in New Zealand male rabbits. The amount of tear secretion was measured with Schirmer's test and then analyzed by a HPLC protocol in order to study the nucleotide levels. Animal eyes were instilled with carbachol (a cholinergic agonist), pirenzepine, gallamine and 4-DAMP (muscarinic antagonists), PPADS, suramin and reactive blue 2 (purinergic antagonists), and a P2Y2 receptor small interfering RNA (siRNA). Tear secretion increased with the instillation of carbachol, approximately 84 % over control values 20 min after the instillation and so did Ap4A and ATP release. When we applied carbachol in the presence of muscarinic antagonists, tear volume only increased to 4 % with atropine, 12 % in the case of pirenzepine, 3 % with gallamine, and 8 % with 4-DAMP. In the presence of carbachol and purinergic antagonists, tear secretion was increased to 12 % (all values compared to basal tear secretion). By analyzing tear secretion induced with carbachol in presence of a P2Y2 receptor siRNA, we found that tear secretion was diminished to 60 %. The inhibition of tear secretion in the presence of carbachol and purinergic antagonists or P2Y2 siRNA occurred with no apparent change in the tear amount of Ap4A. These experiments demonstrated the participation of Ap4A in lacrimal secretion process.

  12. Impact of environmental adaptation on tear film assessments.

    PubMed

    Fagehi, R

    2018-03-01

    The purpose of this study was to investigate the effect of ocular environmental adaptation on clinical tear film assessment. Thirty subjects (male, mean age 23±2.5) participated in this study. A number of clinical tear film tests were applied, including: fluorescein tear break-up time (FTBUT), Schirmer test and tear prism height test (TPH). The tear physiology of each subject was evaluated twice, once immediately when they arrived from the external environment, and then after 30minutes adaptation in the exam room environment. The mean values were: Schirmer test A (22.1±2.99), Schirmer test B (24.2±2.63), FTBUT A (8.00±1.94), FTBUT B (9.13±2.04), TPH A (0.179±0.026) and TPH B* (0.187±0.023). Statistical testing using Wilcoxon-signed rank test showed a significant difference between the Schirmer test results measured at the different times (P=0.008). Also, the FTBUT and tear prism height test results showed significant differences between the two evaluation times, (P=0.001, 0.011, respectively) (A: tear assessed when the subject comes from the outside environment, B: tear film assessed after 30min adaptation in the clinical environment). This study showed a significant difference between the tear film test results evaluated when the subjects were assessed immediately from the outside environment and after an adaptation time in the clinic environment. Practitioners must consider the effect of differences between external and clinical environment adaptation on clinical tear film physiology. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  13. [Alterations in tears aqueous layer during cytostatics treatment].

    PubMed

    Wojciechowska, Katarzyna; Wieckowska-Szakiel, Marzena; Rózalska, Barbara; Jurowski, Piotr

    2013-01-01

    The aim of the study was to evaluate tears secretion, pH and lysozyme activity in tears aqueous layer during chemotherapy in lung, breast and bowel cancer. 36 patients were enrolled to the study. Depending on the type of cancer and type of chemotherapy patients were divided into three groups. Group I (12 patients) diagnosed with non-small-cell lung cancer treated with PE schema (cisplatin, etoposide), Group II (12 patients) with breast cancer treated with FAC schema (fluorouracil, doxorubicin, cyclophosphamide), Group III (12 patients) with bowel cancer treated with FU/LV schema (fluorouracil, leucovorin). In all the patients: Schirmer's I test, pH measurements and lysozyme test were performed. Patients were examined before chemotherapy, after 2nd, 4th, 6th cycle. In group I and II lowering of tears secretion (p < 0.001) was revealed. In group III there was higher tears secretion (p < 0.001). PH was lowered after 2nd chemotherapy course in group I and II. In further treatment pH value were in the same lower level as after the second course. In group III there was higher pH--more alkaline (p < 0.001) after 2nd cycle of treatment and it was on the same level to the end of the examination process. Lowering of lysozyme activity in the tears film in all groups (p < 0.001) was established. The higher alterations of the lysozyme activity were observed in group treated with FAC schema. Cytostatic treatment has major influence on tears aqueous layer causing alterations of tears secretions. PH alterations depending on type of chemotherapy was observed. Lowering of lysozyme activity in tears was observed. All the deteriorations aggravate with duration of chemotherapy. Alterations of tears film parameters during chemotherapy may influence upon eye surface homeostasis and infectious complication. tears aqueous layer, Schirmer's test, lysozyme activity, tears pH.

  14. Deformation associated with continental normal faults

    NASA Astrophysics Data System (ADS)

    Resor, Phillip G.

    Deformation associated with normal fault earthquakes and geologic structures provide insights into the seismic cycle as it unfolds over time scales from seconds to millions of years. Improved understanding of normal faulting will lead to more accurate seismic hazard assessments and prediction of associated structures. High-precision aftershock locations for the 1995 Kozani-Grevena earthquake (Mw 6.5), Greece image a segmented master fault and antithetic faults. This three-dimensional fault geometry is typical of normal fault systems mapped from outcrop or interpreted from reflection seismic data and illustrates the importance of incorporating three-dimensional fault geometry in mechanical models. Subsurface fault slip associated with the Kozani-Grevena and 1999 Hector Mine (Mw 7.1) earthquakes is modeled using a new method for slip inversion on three-dimensional fault surfaces. Incorporation of three-dimensional fault geometry improves the fit to the geodetic data while honoring aftershock distributions and surface ruptures. GPS Surveying of deformed bedding surfaces associated with normal faulting in the western Grand Canyon reveals patterns of deformation that are similar to those observed by interferometric satellite radar interferometry (InSAR) for the Kozani Grevena earthquake with a prominent down-warp in the hanging wall and a lesser up-warp in the footwall. However, deformation associated with the Kozani-Grevena earthquake extends ˜20 km from the fault surface trace, while the folds in the western Grand Canyon only extend 500 m into the footwall and 1500 m into the hanging wall. A comparison of mechanical and kinematic models illustrates advantages of mechanical models in exploring normal faulting processes including incorporation of both deformation and causative forces, and the opportunity to incorporate more complex fault geometry and constitutive properties. Elastic models with antithetic or synthetic faults or joints in association with a master

  15. Influence of Ophthalmic Solutions on Tear Components.

    PubMed

    Shigeyasu, Chika; Yamada, Masakazu; Akune, Yoko

    2016-11-01

    Tear fluids are a mixture of secretions derived from lacrimal glands, accessory lacrimal glands, conjunctiva, and meibomian glands. Compositional changes to tears occur in the normal state and during ocular surface disease, such as dry eye conditions. We have investigated compositional changes to tears after topical application of ophthalmic solutions, with regard to tear-specific proteins (secretory immunoglobulin A, lactoferrin, lipocalin-1, and lysozyme) and ocular surface mucin in normal and dry eye conditions using high-performance liquid chromatography. After application of saline solution (0.9% sodium chloride) in normal subjects, transient but significant decreases in all tear components were observed. The recovery of protein concentrations took up to 30 minutes and lasted longer when the saline solution was applied more frequently. When applying ophthalmic solutions, a balance between washout and dilutional effects should be considered in addition to the therapeutic effect. Investigation of the effect of diquafosol solution (3%) in normal subjects revealed a significant increase in sialic acid concentration, a marker of ocular mucin, at 5 minutes after application, whereas a significant decrease was observed with saline. This result indicates the accelerated secretion of mucin from ocular tissues induced by diquafosol. A clinical study to determine the efficacy of diquafosol in patients with dry eye revealed improvements in tear breakup time, keratoconjunctival staining scores, and Schirmer test score, accompanied by an increase in sialic acid concentration in tears. Investigating normal and dry eye conditions through tear analysis may clarify the pathophysiology of dry eye conditions and support the efficacy of treatments.

  16. Transform Faults and Lithospheric Structure: Insights from Numerical Models and Shipboard and Geodetic Observations

    NASA Astrophysics Data System (ADS)

    Takeuchi, Christopher S.

    In this dissertation, I study the influence of transform faults on the structure and deformation of the lithosphere, using shipboard and geodetic observations as well as numerical experiments. I use marine topography, gravity, and magnetics to examine the effects of the large age-offset Andrew Bain transform fault on accretionary processes within two adjacent segments of the Southwest Indian Ridge. I infer from morphology, high gravity, and low magnetization that the extremely cold and thick lithosphere associated with the Andrew Bain strongly suppresses melt production and crustal emplacement to the west of the transform fault. These effects are counteracted by enhanced temperature and melt production near the Marion Hotspot, east of the transform fault. I use numerical models to study the development of lithospheric shear zones underneath continental transform faults (e.g. the San Andreas Fault in California), with a particular focus on thermomechanical coupling and shear heating produced by long-term fault slip. I find that these processes may give rise to long-lived localized shear zones, and that such shear zones may in part control the magnitude of stress in the lithosphere. Localized ductile shear participates in both interseismic loading and postseismic relaxation, and predictions of models including shear zones are within observational constraints provided by geodetic and surface heat flow data. I numerically investigate the effects of shear zones on three-dimensional postseismic deformation. I conclude that the presence of a thermally-activated shear zone minimally impacts postseismic deformation, and that thermomechanical coupling alone is unable to generate sufficient localization for postseismic relaxation within a ductile shear zone to kinematically resemble that by aseismic fault creep (afterslip). I find that the current record geodetic observations of postseismic deformation do not provide robust discriminating power between candidate linear and

  17. Formation of Hot Tear Under Controlled Solidification Conditions

    NASA Astrophysics Data System (ADS)

    Subroto, Tungky; Miroux, Alexis; Bouffier, Lionel; Josserond, Charles; Salvo, Luc; Suéry, Michel; Eskin, Dmitry G.; Katgerman, Laurens

    2014-06-01

    Aluminum alloy 7050 is known for its superior mechanical properties, and thus finds its application in aerospace industry. Vertical direct-chill (DC) casting process is typically employed for producing such an alloy. Despite its advantages, AA7050 is considered as a "hard-to-cast" alloy because of its propensity to cold cracking. This type of cracks occurs catastrophically and is difficult to predict. Previous research suggested that such a crack could be initiated by undeveloped hot tears (microscopic hot tear) formed during the DC casting process if they reach a certain critical size. However, validation of such a hypothesis has not been done yet. Therefore, a method to produce a hot tear with a controlled size is needed as part of the verification studies. In the current study, we demonstrate a method that has a potential to control the size of the created hot tear in a small-scale solidification process. We found that by changing two variables, cooling rate and displacement compensation rate, the size of the hot tear during solidification can be modified in a controlled way. An X-ray microtomography characterization technique is utilized to quantify the created hot tear. We suggest that feeding and strain rate during DC casting are more important compared with the exerted force on the sample for the formation of a hot tear. In addition, we show that there are four different domains of hot-tear development in the explored experimental window—compression, microscopic hot tear, macroscopic hot tear, and failure. The samples produced in the current study will be used for subsequent experiments that simulate cold-cracking conditions to confirm the earlier proposed model.

  18. Assessment, prevention and management of skin tears.

    PubMed

    Benbow, Maureen

    2017-04-28

    Skin tears are common in older people. They are acute wounds that are at high risk of becoming complex, chronic wounds due to the interplay between the physiological changes in the skin and trauma from the external environment. Skin tears have been reported to have prevalence rates equal to, or greater than, those for pressure ulcers. A comprehensive risk assessment should include assessment of the individual's general health (chronic/critical disease, polypharmacy and cognitive, sensory and nutritional status); mobility (history of falls, impaired mobility, dependent activities of daily living, and mechanical trauma); and skin (extremes of age, fragile skin and previous skin tears). A recognised classification system should be used to identify and document skin tears and guide treatment decisions in line with local wound management protocols. Nurses and carers are in a prime position to prevent, assess and manage skin tears.

  19. Transfer zones and fault reactivation in inverted rift basins: Insights from physical modelling

    NASA Astrophysics Data System (ADS)

    Konstantinovskaya, Elena A.; Harris, Lyal B.; Poulin, Jimmy; Ivanov, Gennady M.

    2007-08-01

    Lateral transfer zones of deformation and fault reactivation were investigated in multilayered silicone-sand models during extension and subsequent co-axial shortening. Model materials were selected to meet similarity criteria and to be distinguished on CT scans; this approach permitted non-destructive visualisation of the progressive evolution of structures. Transfer zones were initiated by an orthogonal offset in the geometry of a basal mobile aluminium sheet and/or by variations of layer thickness or material rheology in basal layers. Transfer zones affected rift propagation and fault kinematics in models. Propagation and overlapping rift culminations occurred in transfer zones during extension. During shortening, deviation in the orientation of frontal thrusts and fold axes occurred within transfer zones in brittle and ductile layers, respectively. CT scans showed that steep (58-67°) rift-margin normal faults were reactivated as reverse faults. The reactivated faults rotated to shallower dips (19-38°) with continuing shortening after 100% inversion. Rotation of rift phase faults appears to be due to deep level folding and uplift during the inversion phase. New thrust faults with shallow dips (20-34°) formed outside the inverted graben at late stages of shortening. Frontal ramps propagated laterally past the transfer structure during shortening. During inversion, the layers filling the rift structures underwent lateral compression at the depth, the graben fill was pushed up and outwards creating local extension near the surface. Sand marker layers in inverted graben have showed fold-like structures or rotation and tilting in the rifts and on the rift margins. The results of our experiments conform well to natural examples of inverted graben. Inverted rift basins are structurally complex and often difficult to interpret in seismic data. The models may help to unravel the structure and evolution of these systems, leading to improved hydrocarbon exploration

  20. Antioxidant content and ultraviolet absorption characteristics of human tears.

    PubMed

    Choy, Camus Kar Man; Cho, Pauline; Benzie, Iris F F

    2011-04-01

    Dry eye syndrome is a common age-related disorder, and decreased antioxidant/ultraviolet (UV) radiation protection in tears may be part of the cause. This study aimed to compare the tear antioxidant content and flow rate in young and older adults. The total antioxidant content and UV absorbing properties of various commercially available ophthalmic solutions used to alleviate dry eye symptoms were also examined. Minimally stimulated tears were collected from 120 healthy Chinese adults with no ocular pathology. Two age groups were studied: 19 to 29 years (n = 58) and 50 to 75 years (n = 62). Tear samples from each subject and 13 ophthalmic solutions were analyzed for total antioxidant content (as the Ferric Reducing/Antioxidant Power value). Tear flow rates were estimated from time taken to collect a fixed volume of tear fluid. UV absorbance spectra of pooled fresh reflex tear fluid and the ophthalmic solutions were determined. Results showed that the antioxidant content of minimally stimulated tears from older subjects (398 ± 160 μmol/l) was not significantly lower than that of younger subjects (348 ± 159 μmol/l; p = 0.0915). However, there was a significant difference in the tear flow rates between the two groups (p < 0.0001), with the younger group having three to four fold higher flow rate. None of the commercial preparations tested had detectable antioxidant content, and none showed the UV absorption characteristics of natural reflex tears. The effect of low flow rate on the dynamic antioxidant supply to the corneal surface indicates that older subjects have poorer overall defense against photooxidative and other oxidative processes. This could predispose older persons to corneal stress and development of dry eye syndrome. The commercially available artificial tears tested lack both the antioxidant content and UV absorbing characteristics of natural tears. Artificial tears formulations that help restore natural antioxidant and UV absorbing properties to the

  1. Structural Mapping Along the Central San Andreas Fault-zone Using Airborne Electromagnetics

    NASA Astrophysics Data System (ADS)

    Zamudio, K. D.; Bedrosian, P.; Ball, L. B.

    2017-12-01

    Investigations of active fault zones typically focus on either surface expressions or the associated seismogenic zones. However, the largely aseismic upper kilometer can hold significant insight into fault-zone architecture, strain partitioning, and fault-zone permeability. Geophysical imaging of the first kilometer provides a link between surface fault mapping and seismically-defined fault zones and is particularly important in geologically complex regions with limited surface exposure. Additionally, near surface imaging can provide insight into the impact of faulting on the hydrogeology of the critical zone. Airborne electromagnetic (AEM) methods offer a unique opportunity to collect a spatially-large, detailed dataset in a matter of days, and are used to constrain subsurface resistivity to depths of 500 meters or more. We present initial results from an AEM survey flown over a 60 kilometer long segment of the central San Andreas Fault (SAF). The survey is centered near Parkfield, California, the site of the SAFOD drillhole, which marks the transition between a creeping fault segment to the north and a locked zone to the south. Cross sections with a depth of investigation up to approximately 500 meters highlight the complex Tertiary and Mesozoic geology that is dismembered by the SAF system. Numerous fault-parallel structures are imaged across a more than 10 kilometer wide zone centered on the surface trace. Many of these features can be related to faults and folds within Plio-Miocene sedimentary rocks found on both sides of the fault. Northeast of the fault, rocks of the Mesozoic Franciscan and Great Valley complexes are extremely heterogeneous, with highly resistive volcanic rocks within a more conductive background. The upper 300 meters of a prominent fault-zone conductor, previously imaged to 1-3 kilometers depth by magnetotellurics, is restricted to a 20 kilometer long segment of the fault, but is up to 4 kilometers wide in places. Elevated fault

  2. Relationship of faults in basin sediments to the gravity and magnetic expression of their underlying fault systems

    USGS Publications Warehouse

    Baldyga, Christopher A.

    2001-01-01

    Gravity and magnetic surveys were performed along the western flanks of the Santa Rita Mountain range located in southeastern Arizona to develop an understanding of the relationship between surface fault scarps within the basin fill sediments and theirgeophysical response of the faults at depth within the bedrock. Data were acquired for three profiles, one of them along the northern terrace of Montosa Canyon, and the other two along the northern and southern terraces of Cottonwood Canyon. A total of 122 gravity stations were established as well as numerous magnetic data collected by a truckmounted cesium-vapor magnetometer. In addition, aeromagnetic data previously acquired were interpreted to obtain a geologically sound model, which produced a good fit to the data. Gravity anomalies associated with faults exhibiting surface rupture were more pronounced than the respective magnetic anomalies. More credence was given to the gravity data when determining fault structures and it was found in all three profiles that faults at depth projected through alluvium at a steeper dip than the bedrock fault indicating brittle behavior within the overlying sediments. The gravity data also detected a significant horst and graben structure within Cottonwood Canyon. The aeromagnetic data did not provide any insight into the response of the minor faults but rather served to verify the regional response of the whole profile.

  3. Reverse shoulder arthroplasty for massive irreparable rotator cuff tears and cuff tear arthropathy: a systematic review.

    PubMed

    Petrillo, S; Longo, U G; Papalia, R; Denaro, V

    2017-08-01

    To report the outcomes and complications of reverse shoulder arthroplasty (RSA) in massive irreparable rotator cuff tears (MIRCT) and cuff tear arthropathy (CTA). A systematic review of the literature contained in Medline, Cochrane, EMBASE, Google Scholar and Ovid databases was conducted on May 1, 2016, according to PRISMA guidelines. The key words "reverse total shoulder arthroplasty" or "reverse total shoulder prostheses" with "rotator cuff tears"; "failed rotator cuff surgery"; "massive rotator cuff tears"; "irreparable rotator cuff tears"; "cuff tear arthropathy"; "outcomes"; "complications" were matched. All articles reporting outcomes and complications of RSA for the management of MIRCT or CTA were included. The comparison between preoperative and postoperative clinical scores, as well as range of motion (ROM), was performed using the Wilcoxon-Mann-Whitney test. P values lower than 0.05 were considered statistically significant. Seven articles were included in our qualitative synthesis. A statistically significant improvement in all clinical scores and ROM was found comparing the preoperative value with the postoperative value. The degrees of retroversion of the humeral stem of the RSA do not influence the functional outcomes in a statistically significant fashion. There were 17.4% of complications. The most frequent was heterotopic ossification, occurring in 6.6% of patients. Revision surgery was necessary in 7.3% of patients. RSA restores pain-free ROM and improves function of the shoulder in patients with MIRCT or CTA. However, complications occur in a high percentage of patients. The lack of level I studies limits the real understanding of the potentials and limitations of RSA for the management of MIRCT and CTA.

  4. Rotator cuff tear and sarcopenia: are these related?

    PubMed

    Chung, Seok Won; Yoon, Jong Pil; Oh, Kyung-Soo; Kim, Hyung Sup; Kim, Young Gun; Lee, Hyun-Joo; Jeong, Won-Ju; Kim, Dong-Hyun; Lee, Jong Soo; Yoon, Jee Wook

    2016-09-01

    Sarcopenia is the loss of muscle mass and consequent loss of muscle function with aging. Its prevalence among the general population is 12% to 30% in those aged >60 years. We evaluated (1) the difference in the prevalence of sarcopenia between patients with rotator cuff tear and controls and (2) the sarcopenia severity according to the size of the rotator cuff tear. Group 1 included 48 consecutive patients with chronic symptomatic full-thickness rotator cuff tears (mean age, 60.1 ± 6.5 years; range, 46-76 years), and group 2 included 48 age- and sex-matched patients. The sarcopenic index was evaluated by using the grip strength of the asymptomatic contralateral side and the skeletal muscle mass. No significant differences were found in the baseline data and demographic factors between the groups. The sarcopenic index was significantly inferior in the rotator cuff tear group than in the age- and sex-matched control groups (P = .041, .007, and .05, respectively). Patients with large to massive tears had a significantly inferior sarcopenic index than those with small and medium tears. The results showed that sarcopenia was more severe in patients with a chronic symptomatic full-thickness rotator cuff tear than in the age- and sex-matched control population and was correlated with the size of the tear, with the numbers available. Despite the individual variance in the underlying medical condition and physical activities, this study suggests that clinicians should consider the sarcopenic condition of patients with a rotator cuff tear, especially in elderly patients with large to massive tears. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  5. Constraining the fault slip rate using morphology of normal fault footwalls: insights from analog and numerical models (Invited)

    NASA Astrophysics Data System (ADS)

    Strak, V.; Dominguez, S.; Petit, C.; Meyer, B.; Loget, N.

    2013-12-01

    Relief evolution in active tectonic areas is controlled by the interactions between tectonics and surface processes (erosion, transport and sedimentation). These interactions lead to the formation of geomorphologic markers that remain stable during the equilibrium reached in the long-term between tectonics and erosion. In regions experiencing active extension, drainage basins and faceted spurs (triangular facets) are such long-lived morphologic markers and they can help in quantifying the competing effects between tectonics, erosion and sedimentation. We performed analog and numerical models simulating the morphologic evolution of a mountain range bounded by a normal fault. In each approach we imposed identical initial conditions. We carried out several models by varying the fault slip rate (V) and keeping a constant rainfall rate allowing us to study the effect of V on morphology. Both approaches highlight the main control of V on the topographic evolution of the footwall. The experimental approach shows that V controls erosion rates (incision rate, erosion rate of slopes and regressive erosion rate) and possibly the height of triangular facets. This approach indicates likewise that the parameter K of the stream power law depends on V even for non-equilibrium topography. The numerical approach corroborates the control of V on erosion rates and facet height. It also shows a correlation between the shape of drainage basins and V (slope-area relationship) and it suggests the same for the parameters of the stream power law. Therefore both approaches suggest the possibility of using the height of triangular facets and the slope-area relationship to infer the fault slip rate of normal faults situated in a given climatic context.

  6. The efficacy, sensitivity, and specificity of strip meniscometry in conjunction with tear function tests in the assessment of tear meniscus.

    PubMed

    Ibrahim, Osama M A; Dogru, Murat; Ward, Samantha K; Matsumoto, Yukihiro; Wakamatsu, Tais Hitomi; Ishida, Katsushi; Tsuyama, Atsushi; Kojima, Takashi; Shimazaki, Jun; Tsubota, Kazuo

    2011-04-06

    To evaluate the specificity and sensitivity of strip meniscometry (SM) testing in conjunction with tear function tests in the diagnosis of dry eye (DE) disease and to investigate the effect of SM on reflex tearing. One hundred seven left eyes of 107 patients with definite DE disease according to the Japanese DE diagnostic criteria and 68 left eyes of 68 age- and sex-matched control subjects were studied. Tear meniscus height (TMH) measurements, fluorescein tear film break-up time (FTBUT), fluorescein (F) and rose bengal (RB) staining, and Schirmer's test-1 (ST) were also performed. The assessment of reflex tearing before and after SM application was assessed with a graticule scale at the slit lamp and by optical coherence tomography. The sensitivity and specificity of SM alone and in combination with tear function tests were also sought. The SM scores, TMH measurements, FTBUTs, and STs were significantly lower in dry eye patients than in the controls (P < 0.001). The RB and F staining scores were significantly higher in the dry eye group than in the control group (P < 0.001). The meniscometry strips did not induce significant changes in relation to reflex tearing. SM had an acceptable sensitivity and specificity. SM is a swift, noninvasive, promising method of assessing tear meniscus volume. The combined SM and FTBUT examination appears to be a sensitive approach to the assessment of dry eye disease.

  7. Role of N-S strike-slip faulting in structuring of north-eastern Tunisia; geodynamic implications

    NASA Astrophysics Data System (ADS)

    Arfaoui, Aymen; Soumaya, Abdelkader; Ben Ayed, Noureddine; Delvaux, Damien; Ghanmi, Mohamed; Kadri, Ali; Zargouni, Fouad

    2017-05-01

    Three major compressional events characterized by folding, thrusting and strike-slip faulting occurred in the Eocene, Late Miocene and Quaternary along the NE Tunisian domain between Bou Kornine-Ressas-Msella and Cap Bon Peninsula. During the Plio-Quaternary, the Grombalia and Mornag grabens show a maximum of collapse in parallelism with the NNW-SSE SHmax direction and developed as 3rd order distensives zones within a global compressional regime. Using existing tectonic and geophysical data supplemented by new fault-kinematic observations, we show that Cenozoic deformation of the Mesozoic sedimentary sequences is dominated by first order N-S faults reactivation, this sinistral wrench system is responsible for the formation of strike-slip duplexes, thrusts, folds and grabens. Following our new structural interpretation, the major faults of N-S Axis, Bou Kornine-Ressas-Messella (MRB) and Hammamet-Korbous (HK) form an N-S first order compressive relay within a left lateral strike-slip duplex. The N-S master MRB fault is dominated by contractional imbricate fans, while the parallel HK fault is characterized by a trailing of extensional imbricate fans. The Eocene and Miocene compression phases in the study area caused sinistral strike-slip reactivation of pre-existing N-S faults, reverse reactivation of NE-SW trending faults and normal-oblique reactivation of NW-SE faults, creating a NE-SW to N-S trending system of east-verging folds and overlaps. Existing seismic tomography images suggest a key role for the lithospheric subvertical tear or STEP fault (Slab Transfer Edge Propagator) evidenced below this region on the development of the MRB and the HK relay zone. The presence of extensive syntectonic Pliocene on top of this crustal scale fault may be the result of a recent lithospheric vertical kinematic of this STEP fault, due to the rollback and lateral migration of the Calabrian slab eastward.

  8. Thrust-wrench fault interference in a brittle medium: new insights from analogue modelling experiments

    NASA Astrophysics Data System (ADS)

    Rosas, Filipe; Duarte, Joao; Schellart, Wouter; Tomas, Ricardo; Grigorova, Vili; Terrinha, Pedro

    2015-04-01

    We present analogue modelling experimental results concerning thrust-wrench fault interference in a brittle medium, to try to evaluate the influence exerted by different prescribed interference angles in the formation of morpho-structural interference fault patterns. All the experiments were conceived to simulate simultaneous reactivation of confining strike-slip and thrust faults defining a (corner) zone of interference, contrasting with previously reported discrete (time and space) superposition of alternating thrust and strike-slip events. Different interference angles of 60°, 90° and 120° were experimentally investigated by comparing the specific structural configurations obtained in each case. Results show that a deltoid-shaped morpho-structural pattern is consistently formed in the fault interference (corner) zone, exhibiting a specific geometry that is fundamentally determined by the different prescribed fault interference angle. Such angle determines the orientation of the displacement vector shear component along the main frontal thrust direction, determining different fault confinement conditions in each case, and imposing a complying geometry and kinematics of the interference deltoid structure. Model comparison with natural examples worldwide shows good geometric and kinematic similarity, pointing to the existence of matching underlying dynamic process. Acknowledgments This work was sponsored by the Fundação para a Ciência e a Tecnologia (FCT) through project MODELINK EXPL/GEO-GEO/0714/2013.

  9. Polyimide Film of Increased Tear Strength

    NASA Technical Reports Server (NTRS)

    St. Clair, A. K.; Hinkley, J. A.; Ezzell, S. A.

    1986-01-01

    High-temperature linear aromatic polyimide with improved resistance to tearing made by new process that incorporates elastomer into polyimide. Linear aromatic condensation polyimides are materials of prime choice for use as films and coatings on advanced spacecraft and aircraft where durability at temperatures in range of 200 to 300 degree C required. Elastomer-containing polyimide film with improved toughness proves useful for applications where resistance to tearing and long-term thermal stability necessary. Desired resistance to tearing achieved by careful control of amount and chemical composition of added elastomer.

  10. Age-related changes in the signal value of tears.

    PubMed

    Zeifman, Debra M; Brown, Sarah A

    2011-08-12

    Emotional tears may be uniquely human and are an effective signal of distress in adults. The present study explored whether tears signal distress in younger criers and whether the effect of tears on observers is similar in magnitude across the life span. Participants rated photographs of crying infants, young children, and adults, with tears digitally removed or added. The effectiveness of tears in conveying sadness and eliciting sympathy was greatest for images of adults, intermediate for images of children, and least potent for images of infants. These findings suggest that the signal value of tears varies with the age of the crier. The results may shed light on the functional significance of crying at different stages of human development.

  11. Neurostimulation of the Lacrimal Nerve for Enhanced Tear Production

    PubMed Central

    Kossler, Andrea L.; Wang, Jianhua; Feuer, William; Tse, David T.

    2014-01-01

    Purpose To design a proof-of-concept study to assess the effect of lacrimal nerve stimulation (LNS) with an implantable pulse generator (IPG) to increase aqueous tear production. Methods Experimental animal study design of six Dutch Belted rabbits. Ultra high-resolution optical coherence tomography (UHR-OCT) quantified tear production by measuring the baseline tear volume of each rabbit’s right and left eye. A neurostimulator was implanted adjacent to the right lacrimal nerve. After two minutes of LNS (100 μs, 1.6 mAmp, 20 Hz, 5–8 volts), the tear volumes were measured with UHR-OCT. The change in tear volume was quantified and compared to the non-stimulated left eye. Three rabbits underwent chronic LNS (100 μS, 1.6 mAmp, 10 Hz, 2 volts) and their lacrimal glands were harvested for histopathologic analysis. Results UHR-OCT imaging of the right eyes tear volume showed a 441% average increase in tear production after LNS as a percent of baseline. After stimulation, right eyes had statistically significant greater increase in tear volumes than left eyes (p=0.028, Wilcoxon test). Post-stimulation right eye tear volumes were significantly greater compared to baseline (p=0.028, Wilcoxon test). Histopathologic examination of the lacrimal glands showed no discernible tissue damage from chronic neurostimulation. Additionally, there were no gross adverse effects on the general well-beings of the animals due to chronic stimulation. Conclusions Lacrimal nerve stimulation with an implantable pulse generator appears to increase aqueous tear production. Chronic LNS showed no histopathologic lacrimal gland damage. This study suggests LNS is a promising new treatment strategy to increase aqueous tear production. PMID:25126767

  12. Strain rate effect on fault slip and rupture evolution: Insight from meter-scale rock friction experiments

    NASA Astrophysics Data System (ADS)

    Xu, Shiqing; Fukuyama, Eiichi; Yamashita, Futoshi; Mizoguchi, Kazuo; Takizawa, Shigeru; Kawakata, Hironori

    2018-05-01

    We conduct meter-scale rock friction experiments to study strain rate effect on fault slip and rupture evolution. Two rock samples made of Indian metagabbro, with a nominal contact dimension of 1.5 m long and 0.1 m wide, are juxtaposed and loaded in a direct shear configuration to simulate the fault motion. A series of experimental tests, under constant loading rates ranging from 0.01 mm/s to 1 mm/s and under a fixed normal stress of 6.7 MPa, are performed to simulate conditions with changing strain rates. Load cells and displacement transducers are utilized to examine the macroscopic fault behavior, while high-density arrays of strain gauges close to the fault are used to investigate the local fault behavior. The observations show that the macroscopic peak strength, strength drop, and the rate of strength drop can increase with increasing loading rate. At the local scale, the observations reveal that slow loading rates favor generation of characteristic ruptures that always nucleate in the form of slow slip at about the same location. In contrast, fast loading rates can promote very abrupt rupture nucleation and along-strike scatter of hypocenter locations. At a given propagation distance, rupture speed tends to increase with increasing loading rate. We propose that a strain-rate-dependent fault fragmentation process can enhance the efficiency of fault healing during the stick period, which together with healing time controls the recovery of fault strength. In addition, a strain-rate-dependent weakening mechanism can be activated during the slip period, which together with strain energy selects the modes of fault slip and rupture propagation. The results help to understand the spectrum of fault slip and rock deformation modes in nature, and emphasize the role of heterogeneity in tuning fault behavior under different strain rates.

  13. Holocene surface ruptures of the Rurrand Fault, Germany—insights from palaeoseismology, remote sensing and shallow geophysics

    NASA Astrophysics Data System (ADS)

    Grützner, Christoph; Fischer, Peter; Reicherter, Klaus

    2016-03-01

    The Lower Rhine Embayment in Central Europe hosts a rift system that has very low deformation rates. The faults in this area have slip rates of less than 0.1 mm yr-1, which does not allow to investigate ongoing tectonic deformation with geodetic techniques, unless they cover very long time spans. Instrumental seismicity does only cover a small fraction of the very long earthquake recurrence intervals of several thousands of years. Palaeoseismological studies are needed to constrain slip rates and the earthquake history of such faults. Destructive earthquakes are rare in the study area, but did occur in historic times. In 1755/1756, a series of strong earthquakes caused significant destruction in the city of Düren (Germany) and the surrounding areas. In this study we document palaeoseismological data from the nearby Rurrand Fault. In contrast to earlier studies on the same fault, we found evidence for a surface rupturing earthquake in the Holocene, and we identified at least one more surface rupturing event. Our study shows that the Rurrand Fault currently accommodates deformation in earthquakes rather than by creeping. The coseismic offsets were determined to be between less than 0.5 m per event. We assign maximum possible magnitudes of Mw 5.9-6.8 for the Rurrand Fault and a slip rate of at least 0.02-0.03 mm yr-1 for the last ˜130-50 kyr. The surface ruptures did not occur at the main fault trace that has a clear morphological expression due to older tectonic motions, but on a younger fault strand in the hanging wall of the main fault. Terrain analyses based on 1 m resolution airborne LiDAR data have been used to image the subtle morphological expression of this young fault zone. Georadar and electric resistivity tomography were applied to image the fault zone at depth and to test if these shallow geophysical methods can be used to identify and trace the fault zone. Georadar failed to produce reliable results, but geoelectrics were successfully applied and

  14. Duplex Tear Film Evaporation Analysis.

    PubMed

    Stapf, M R; Braun, R J; King-Smith, P E

    2017-12-01

    Tear film thinning, hyperosmolarity, and breakup can cause irritation and damage to the human eye, and these form an area of active investigation for dry eye syndrome research. Recent research demonstrates that deficiencies in the lipid layer may cause locally increased evaporation, inducing conditions for breakup. In this paper, we explore the conditions for tear film breakup by considering a model for tear film dynamics with two mobile fluid layers, the aqueous and lipid layers. In addition, we include the effects of osmosis, evaporation as modified by the lipid, and the polar portion of the lipid layer. We solve the system numerically for reasonable parameter values and initial conditions and analyze how shifts in these cause changes to the system's dynamics.

  15. New Insights on Seismicity and the Velocity Structure beneath the Western Segment of the North Anatolian Fault Zone

    NASA Astrophysics Data System (ADS)

    Teoman, U.; Altuncu Poyraz, S.; Kahraman, M.; Mutlu, A. K.; Cambaz, D.; Turkelli, N.; Thompson, D. A.; Rost, S.; Houseman, G. A.; Utkucu, M.

    2014-12-01

    To extensively investigate the upper crustal structure beneath the western segment of the North Anatolian Fault Zone (NAFZ) in Sakarya and the surroundings, a temporary seismic network consisting of 70 stations (with nearly 7km station spacing) was deployed in early May 2012 and operated for 18 months during the Faultlab experiment encompassing both the northern and southern strands of the fault in between the area of 1999 İzmit and Düzce mainshock ruptures. With the help of this new and extensive data set, our main objective is to provide new insights on the most recent micro-seismic activity and the velocity structure beneath the region. Out of 2437 events contaminated by the explosions, we extracted 1344 well located earthquakes with a total of 31595 P and 18512 S phase readings which lead to an avarage Vp/Vs ratio of ~1.82 extracted from the wadati diagram. The enhanced station coverage decreased the magnitude threshold to 0.1 where the horizontal and vertical location errors did not exceed 0.5 km and 2.0 km, respectively. Average RMS values were calculated within the range of 0.05-0.4 seconds. We observed significant seismic activity along both branches of the fault where the depth of the seismogenic zone was confined to 15 km. Focal parameters of 41 earthquakes with magnitudes greater than 1.8 were also determined using both Regional Moment Tensor Inversion and P first arrival time methods. Focal mechanism solutions confirm that Sakarya and its vicinity could be defined by a compressional regime showing a primarily oblique-slip motion character. Furthermore, we selected the earthquakes recorded by at least 8 stations with azimuthal gaps less than 200° for the ongoing tomographic inversion that would enable us to accurately map the complex upper crustal velocity structure with high resolution beneath this segment of the NAFZ.

  16. Sphincter tears in primiparous women: Is age a factor?

    PubMed Central

    BOWLING, C. Bryce; WHEELER, Thomas L.; GERTEN, Kimberly A.; CHAPMAN, Victoria R.; BURGIO, Kathryn L.; RICHTER, Holly E.

    2011-01-01

    Introduction and Hypothesis Anal sphincter tears during vaginal delivery may result in serious sequelae. We examined whether younger primiparous patients were at increased risk for sphincter tears during vaginal delivery. Methods Data from an obstetric automated record were analyzed. Primiparous women delivering term infants (n = 5,937) were included to test for an association between age and sphincter tear rates. Three age groups were considered: young adolescents (≤16 years), older adolescents (17-20 years) and adults (≥21 years). Results No significant difference was found in tear rates among age cohorts (9.2%, 8.0%, and 9.6% respectively; p = 0.12). Logistic regression modeling revealed that young adolescents were not more likely to have sphincter tears compared to older cohorts. Conclusions Younger adolescents may not be at increased risk of anal sphincter tears. Decisions regarding interventions to decrease sphincter tears during vaginal delivery should not be made on the basis of maternal age alone. PMID:18985267

  17. Strike-slip fault propagation and linkage via work optimization with application to the San Jacinto fault, California

    NASA Astrophysics Data System (ADS)

    Madden, E. H.; McBeck, J.; Cooke, M. L.

    2013-12-01

    efficiency provided by both hard-linkage and soft-linkage to be quantified and compared. Specialized models of interactions over the past 1 Ma between the Clark and Coyote Creek faults within the San Jacinto system reveal increasing mechanical efficiency as these fault structures change over time. Alongside this increasing efficiency is an increasing likelihood for single, larger earthquakes that rupture multiple fault segments. These models reinforce the sensitivity of mechanical efficiency to both fault structure and the regional tectonic stress orientation controlled by plate motions and provide insight into how slip may have been partitioned between the San Andreas and San Jacinto systems over the past 1 Ma.

  18. Diet, nutraceuticals and the tear film.

    PubMed

    Jalbert, Isabelle

    2013-12-01

    Nutrition disorders and their correlates such as obesity are increasingly prevalent worldwide. A number of studies to date have suggested numerous potential associations between diet and tear film health; this paper will provide a summary of the available literature. The tear film is characterized through its protein and lipid content and through clinical measurements of characteristics such as osmolarity, volume and stability. Malnutrition, protein and vitamin-A deficiencies are extremely deleterious to tear film health and supplementation with oral vitamin A in this setting is of clear benefit. The relative impact of diet on tear film within what would be considered normal ranges of consumption is less clear. A number of population studies have suggested that hyperlipidemia and a diet low in omega-3 fatty acids are risks factor for dry eye disease. Numerous studies have investigated the effectiveness of oral supplementation with antioxidants, omega-3 (e.g. fish oil and linseed oil) and omega-6 (e.g. evening primrose oil) fatty acids in the last 10 years. Taken together, these suggest a small benefit of oral supplementation on tear film volume, stability and decreased ocular symptoms in patients previously diagnosed with diseases involving the ocular surface (e.g. Sjögren's syndrome, meibomian gland dysfunction, dry eye disease) and contact lens wearers suffering from dry eye. More research is required to determine the exact composition, dosage and indications for their use and to fully characterize how these nutraceuticals modulate the tear film. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Effectiveness of Combined Tear Film Therapy in Patients with Evaporative Dry Eye with Short Tear Film Breakup Time.

    PubMed

    Kim, Yung Hui; Kang, Yeon Soo; Lee, Hyo Seok; Choi, Won; You, In Cheon; Yoon, Kyung Chul

    2017-10-01

    The aim of this study was to evaluate the effectiveness of combined tear film therapy targeted to aqueous, mucin, and lipid layers in patients with refractory evaporative dry eye (EDE) with short tear film breakup time (TBUT). The patients who had EDE with short TBUT and severe symptoms refractory to artificial tears were treated with hyaluronic acid (HA) 0.15% and diquafosol tetrasodium (DQS) 3% (Group 1), HA and carbomer-based lipid-containing eyedrops (Liposic EDO Gel, LPO) (Group 2), or HA, DQS, and LPO (Group 3). Ocular Surface Disease Index (OSDI) score, visual analog scale (VAS) symptom score, TBUT, Schirmer score, and corneal and conjunctival staining scores were evaluated, and noninvasive tear film breakup time (NIBUT) and tear meniscus height were measured using Keratograph ® 5 M before and 1 and 3 months after treatment. OSDI scores, VAS scores, TBUT, and NIBUT were improved at 1 and 3 months after treatment in all groups (all P < 0.05). At each follow-up visit, the total OSDI, OSDI symptom, and all VAS scores were significantly lower in group 3 compared with groups 1 and 2 (all P < 0.05). In addition, TBUT and NIBUT were significantly higher in group 3 compared with groups 1 and 2 (all P < 0.05). No significant adverse effects were noted in the groups during treatment. Mucin or lipid-targeting agents combined with aqueous supplements in patients with refractory EDE with short TBUT might improve subjective symptoms and TBUT. Of this, targeting whole tear film layers was most effective in improving ocular symptoms and tear film quality.

  20. Comparison of Medial and Lateral Meniscus Root Tears.

    PubMed

    Koo, Ji Hyun; Choi, Sang-Hee; Lee, Seung Ah; Wang, Joon Ho

    2015-01-01

    The meniscus root plays an essential role in maintaining the circumferential hoop tension and preventing meniscal displacement. Studies on meniscus root tears have investigated the relationship of osteoarthritis and an anterior cruciate ligament tear. However, few studies have directly compared the medial and lateral root tears. To assess the prevalence of meniscal extrusion and its relationship with clinical features in medial and lateral meniscus root tears, we performed a retrospective review of the magnetic resonance imaging (MRI) results of 42 knee patients who had meniscus posterior horn root tears and who had undergone arthroscopic operations. The presence of meniscal extrusion was evaluated and the exact extent was measured from the tibial margin. The results were correlated with arthroscopic findings. Clinical features including patients' ages, joint abnormalities, and previous trauma histories were evaluated. Twenty-two patients had medial meniscus root tears (MMRTs) and twenty patients had lateral meniscus root tears (LMRTs). Meniscal extrusion was present in 18 MMRT patients and one LMRT patient. The mean extent of extrusion was 4.2mm (range, 0.6 to 7.8) in the MMRT group and 0.9mm (range, -1.9 to 3.4) in the LMRT group. Five patients with MMRT had a history of trauma, while 19 patients with LMRT had a history of trauma. Three patients with MMRT had anterior cruciate ligament (ACL) tears, while 19 patients with LMRT had ACL tears. The mean age of the patients was 52 years (range: 29-71 years) and 30 years (range: 14-62 years) in the MMRT and LMRT group, respectively. There was a significant correlation between a MMRT and meniscal extrusion (p<0.0001), and between an ACL tear and LMRT (p<0.0001). A history of trauma was significantly common in LMRT (p<0.0001). LMRT patients were significantly younger than MMRT patients (p<0.0001). Kellgren-Lawrence (K-L) grade differed significantly between MMRT and LMRT group (p<0.0001). Meniscal extrusion is common in

  1. Comparison of Medial and Lateral Meniscus Root Tears

    PubMed Central

    Koo, Ji Hyun; Choi, Sang-Hee; Lee, Seung Ah; Wang, Joon Ho

    2015-01-01

    The meniscus root plays an essential role in maintaining the circumferential hoop tension and preventing meniscal displacement. Studies on meniscus root tears have investigated the relationship of osteoarthritis and an anterior cruciate ligament tear. However, few studies have directly compared the medial and lateral root tears. To assess the prevalence of meniscal extrusion and its relationship with clinical features in medial and lateral meniscus root tears, we performed a retrospective review of the magnetic resonance imaging (MRI) results of 42 knee patients who had meniscus posterior horn root tears and who had undergone arthroscopic operations. The presence of meniscal extrusion was evaluated and the exact extent was measured from the tibial margin. The results were correlated with arthroscopic findings. Clinical features including patients’ ages, joint abnormalities, and previous trauma histories were evaluated. Twenty-two patients had medial meniscus root tears (MMRTs) and twenty patients had lateral meniscus root tears (LMRTs). Meniscal extrusion was present in 18 MMRT patients and one LMRT patient. The mean extent of extrusion was 4.2mm (range, 0.6 to 7.8) in the MMRT group and 0.9mm (range, -1.9 to 3.4) in the LMRT group. Five patients with MMRT had a history of trauma, while 19 patients with LMRT had a history of trauma. Three patients with MMRT had anterior cruciate ligament (ACL) tears, while 19 patients with LMRT had ACL tears. The mean age of the patients was 52 years (range: 29–71 years) and 30 years (range: 14–62 years) in the MMRT and LMRT group, respectively. There was a significant correlation between a MMRT and meniscal extrusion (p<0.0001), and between an ACL tear and LMRT (p<0.0001). A history of trauma was significantly common in LMRT (p<0.0001). LMRT patients were significantly younger than MMRT patients (p<0.0001). Kellgren-Lawrence (K-L) grade differed significantly between MMRT and LMRT group (p<0.0001). Meniscal extrusion is

  2. Lipid peroxidation is increased in tears from the elderly.

    PubMed

    Benlloch-Navarro, Soledad; Franco, Ilenia; Sánchez-Vallejo, Violeta; Silvestre, Dolores; Romero, Francisco Javier; Miranda, María

    2013-10-01

    We describe a procedure in which tears, obtained from Schirmer strips, are used to measure a marker of lipid peroxidation, malondialdehyde (MDA). We also compared the levels of proteins and MDA in tears from two groups of people: young adults (18-30 years old) and elderly adults (65-85 years old), because the data related to total protein concentration of human tears vary widely and because the majority of people over the age of 65 experience some symptoms of dry eyes and this condition has been recognized as an oxidative stress-induced disease. Our results show a significant difference in the protein concentration of the tears taken from the two age categories, younger adults (18-30 years old) and older adults (65-85 years old). Herein, we report for the first time an increase in MDA concentrations determined by HPLC in human tears based on age. It is possible that alterations in the tear lipid layer may lead to an increase in lipid peroxidation. Further studies are needed to understand the nature and function of tear film and stability in order to obtain new methods to analyze tears in patients with different diseases. In this sense, it would be interesting to compare MDA concentration in tears from control subjects and from people with meibomian gland dysfunction. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Relationship of ABO Blood Type on Rotator Cuff Tears.

    PubMed

    Lee, Doo-Hyung; Lee, Han-Dong; Yoon, Seung-Hyun

    2015-11-01

    ABO blood groups are associated with various diseases. A relationship between Achilles tendon ruptures and blood type O has been reported, although its pathogenesis was not clear. To the best of our knowledge, there is no published study describing the relationship between blood type and rotator cuff tendon tears. To determine whether patients with rotator cuff tear had a greater prevalence of blood type O than those without rotator cuff tear. A cross-sectional study. Research hospital outpatient evaluation. A total of 316 subjects with shoulder pain were included and divided into "tear" and "no-tear" groups according to ultrasonographic examination. ABO blood group, gender, dominant arm, smoking history, trauma history, and age were compared between the 2 groups and the odds ratios of these factors were evaluated by logistic regression. The tear group (38.6%) had more instances of blood type O than the healthy population (27.2%; P = .002). The adjusted odds ratio for rotator cuff tear for blood type O to non-O was 2.38 (95% confidence interval 1.28-4.42). The odds ratios for rotator cuff tears for smoking, major trauma history, minor trauma history, and age were 2.08, 3.11, 2.29, and 1.06, respectively. Patients with rotator cuff tears were more likely to have blood type O. The odds ratios of factors for rotator cuff tears were high in the following order: major trauma history, blood type O, minor trauma history, and age. Copyright © 2015 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  4. Allergy and allergic mediators in tears.

    PubMed

    Leonardi, Andrea

    2013-12-01

    The identification of inflammatory mediators in the tear fluid have been extensively used in ocular allergy to find either a 'disease marker', to better understand the immune mechanisms involved in the ocular surface inflammation, or to identify potential targets for therapeutic interventions. While the clinical characteristics allow a relatively convincing diagnosis of ocular allergic diseases, in the initial, non active phases, or in the chronic stages, the diagnosis may not be clear. Although not highly specific, total tear IgE can be measured with local tests by inserting a paper strip in the lower meniscus. The measurement of tear specific inflammatory markers, such as histamine, tryptase, ECP, IL-4, IL-5 and eotaxin, may be useful for the diagnosis or monitoring ocular allergy. New technologies such as multiplex bead assays, membrane-bound antibody array and proteomic techniques can characterize the distribution of a wide range of bioactive trace proteins in tears. Dozens of mediators, cytokines, chemokines, growth factors, angiogenic modulators, enzymes and inhibitors were thus identified in small tear samples using these techniques, providing the possible identification of specific biomarker for either specific disease or disease activity. However, to date, there is no a single specific laboratory test suitable for the diagnosis and monitoring of allergic conjunctivitis. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Effect of Ambient Temperature on the Human Tear Film.

    PubMed

    Abusharha, Ali A; Pearce, E Ian; Fagehi, Raied

    2016-09-01

    During everyday life, the tear film is exposed to a wide range of ambient temperatures. This study aims to investigate the effect of ambient temperature on tear film physiology. A controlled environment chamber was used to create different ambient temperatures (5, 10, 15, 20, and 25°C) at a constant relative humidity of 40%. Subjects attended for two separate visits and were exposed to 25, 20, and 15°C at one visit and to 10 and 5°C at the other visit. The subjects were exposed to each room temperature for 10 min before investigating tear film parameters. The order of the visits was random. Tear physiology parameters assessed were tear evaporation rate, noninvasive tear break-up time (NITBUT), lipid layer thickness (LLT), and ocular surface temperature (OST). Each parameter was assessed under each condition. A threefold increase in tear evaporation rate was observed as ambient temperature increased to 25°C (P=0.00). The mean evaporation rate increased from 0.056 μL/min at 5°C to 0.17 μL/min at 25°C. The mean NITBUT increased from 7.31 sec at 5°C to 12.35 sec at 25°C (P=0.01). A significant change in LLT was also observed (P=0.00), LLT median ranged between 20 and 40 nm at 5 and 10°C and increased to 40 and 90 nm at 15, 20, and 25°C. Mean reduction of 4°C OST was observed as ambient temperature decreased from 25 to 5°C. Ambient temperature has a considerable effect on human tear film characteristics. Tear evaporation rate, tear LLT, tear stability, and OST were considerably affected by ambient temperature. Chronic exposure to low ambient temperature would likely result in symptoms of dry eye and ultimately ocular surface disorders.

  6. Fault-related structural permeability: Qualitative insights of the damage-zone from micro-CT analysis.

    NASA Astrophysics Data System (ADS)

    Gomila, Rodrigo; Arancibia, Gloria; Nehler, Mathias; Bracke, Rolf; Stöckhert, Ferdinand

    2016-04-01

    Fault zones and their related structural permeability play a leading role in the migration of fluids through the continental crust. A first approximation to understanding the structural permeability conditions, and the estimation of its hydraulic properties (i.e. palaeopermeability and fracture porosity conditions) of the fault-related fracture mesh is the 2D analysis of its veinlets, usually made in thin-section. Those estimations are based in the geometrical parameters of the veinlets, such as average fracture density, length and aperture, which can be statistically modelled assuming penny-shaped fractures of constant radius and aperture within an anisotropic fracture system. Thus, this model is related to fracture connectivity, its length and to the cube of the fracture apertures. In this way, the estimated values presents their own inaccuracies owing to the method used. Therefore, the study of the real spatial distribution of the veinlets of the fault-related fracture mesh (3D), feasible with the use of micro-CT analyses, is a first order factor to unravel both, the real structural permeability conditions of a fault-zone, together with the validation of previous estimations made in 2D analyses in thin-sections. This early contribution shows the preliminary results of a fault-related fracture mesh and its 3D spatial distribution in the damage zone of the Jorgillo Fault (JF), an ancient subvertical left-lateral strike-slip fault exposed in the Atacama Fault System in northern Chile. The JF is a ca. 20 km long NNW-striking strike-slip fault with sinistral displacement of ca. 4 km. The methodology consisted of the drilling of vertically oriented plugs of 5 mm in diameter located at different distances from the JF core - damage zone boundary. Each specimen was, then, scanned with an x-ray micro-CT scanner (ProCon X-Ray CTalpha) in order to assess the fracture mesh. X-rays were generated in a transmission target x-ray tube with acceleration voltages ranging from 90

  7. ­Tectonic and geomorphic setting of the Pamir Plateau: Insights from InSAR and teleseismic analysis of the 2015 Lake Saurez and 2016 Muji fault earthquake sequence

    NASA Astrophysics Data System (ADS)

    Nanjundiah, P.; Barbot, S.; Wei, S.; Tapponnier, P.; Feng, W.; Wang, T.

    2017-12-01

    The Pamir Plateau lies on the western edge of the India- Eurasia collision zone and has been the sight of complex subduction regime in the past 50 Ma. In our study, we focus on two earthquakes and their aftershocks that occurred between December 2015 and December 2016. The first earthquake (Mw7.2), on 7 December 2015 between the Karakoram and Darwas fault systems, was sinstral strike slip in nature. The earthquake on 25 November (Mw6.6) occurred on the western end of Muji Fault, a dextral strike slip fault with an avg slip rate of 4mm/yr. We aim to better understand the structure, stress and deformation patterns in the northern and central Pamir plateau by analyzing InSAR, teleseismic, and optical data for these events and their aftershocks. We aim to better understand the structure, stress and deformation patterns in the northern and central Pamir plateau by analysing InSAR, teleseismic, and optical data for these events and their aftershocks. We constrain the fault geometry by precisely relocating aftershocks using the double difference technique implemented in HypoDD (Waldhauser & Ellsworth 2000). We used the Green's functions of Okada (1992) to invert for slip on the fault with rectangular dislocation and edgreen to numerically invert for the slip in a layered medium (Wang et al. 2003). The surface rupture of the December 2015 Lake Saurez earthquake shows evidence of multiple segments and step-overs. The combination of data sets used in this study highlights the existence of a seismic gap south of Lake Karakul as well as coupling between the Muji and Darwas-Karakoram fault systems. Mapping of past ruptures shows that the Sarez fault continues along the eastern coast of Lake Karakul almost until the Muji fault. With near field geodetic data in the form of InSAR, we can get a better insight into complex fault structures as well as post seismic slip and strain along the faults and its surroundings. We emphasize the role of smaller faults and their interactions in

  8. Tear dysfunction and the cornea: LXVIII Edward Jackson Memorial Lecture.

    PubMed

    Pflugfelder, Stephen C

    2011-12-01

    To describe the cause and consequence of tear dysfunction-related corneal disease. Perspective on effects of tear dysfunction on the cornea. Evidence is presented on the effects of tear dysfunction on corneal morphology, function, and health, as well as efficacy of therapies for tear dysfunction-related corneal disease. Tear dysfunction is a prevalent eye disease and the most frequent cause for superficial corneal epithelial disease that results in corneal barrier disruption, an irregular optical surface, light scattering, optical aberrations, and exposure and sensitization of pain-sensing nerve endings (nociceptors). Tear dysfunction-related corneal disease causes irritation and visual symptoms such as photophobia and blurred and fluctuating vision that may decrease quality of life. Dysfunction of 1 or more components of the lacrimal functional unit results in changes in tear composition, including elevated osmolarity and increased concentrations of matrix metalloproteinases, inflammatory cytokines, and chemokines. These tear compositional changes promote disruption of tight junctions, alter differentiation, and accelerate death of corneal epithelial cells. Corneal epithelial disease resulting from tear dysfunction causes eye irritation and decreases visual function. Clinical and basic research has improved understanding of the pathogenesis of tear dysfunction-related corneal epithelial disease, as well as treatment outcomes. Copyright © 2011 Elsevier Inc. All rights reserved.

  9. Immunoglobulin Concentration in Tears of Contact Lens Wearers

    PubMed Central

    Maurya, Rajendra P.; Bhushan, Prashant; Singh, Virendra P.; Singh, Mahendra K.; Kumar, Prakash; Bhatia, Ravindra P.S.; Singh, Usha

    2014-01-01

    Purpose: To evaluate changes in the concentration of tear immunoglobulins in contact lens wearers. Methods: A total of 45 cases including 23 contact lens wearers (43 eyes) and 22 age and sex matched healthy controls having no ocular pathology were studied for immunoglobulins (IgA, IgG, IgM) in their tears by single radial immunodiffusion method. Results: Most of the cases used soft (56.6%) and semi-soft gas permeable (30.4%) contact lenses. Tear IgM was detected in only 17.4% and tear IgG in 43.6% of contact lens wearers, while in controls IgG was detected in 9.1% but none of the controls had IgM. There was a significant rise in total tear IgA (13.17 ± 4.44 mg/dl) in contact lens wearer as compared to controls (8.93 ± 3.79 mg/dl). Rise of tear IgA was more in symptomatic patients (15.38 ± 5.28 mg/dl) and in those wearing hard (19.73 ± 5.43 mg/dl) and semi-soft contact lenses (13.31 ± 5.43 mg/dl). A significant increase in tear IgA was noticed in subjects wearing lenses for >3 years (15.69 ± 5.39 mg/dl). About 43.4% of lens wearers were symptomatic and 80% of their lenses showed deposits and/or haziness. All cases with IgM in tear were symptomatic. Conclusion: The relation of immunoglobulin concentration with increasing duration of wear and material of contact lens shows that tear immunoglobulin rise accrues due to mechanical stimulation, hence contact lenses should not be used for a long period and lenses of hard nature should be discouraged. The maintenance, cleaning and deproteinization of the lenses are of high importance to avoid immunostimulation. PMID:25667732

  10. Tearfulness: a psychoanalytic interpretation.

    PubMed

    Wood, E C; Wood, C D

    1984-01-01

    In our view, the tearful feeling state is occasioned by the ego temporarily threatened with being inundated by complex memories and affects. For the moment, the ego cannot provide appropriate satisfying and integrated verbal expression. Words and verbal thinking are delayed. In this brief period, a controlled regression occurs during which the ego relates the current "precipitating experience" to temporally older conflictual experiences in the presence of the current object as a transference object and with a series of relationships so closely connected to that experience that they are interchanged in whole or part by the less selective, regressed, ego operations. The conscious experience may be sadness, gratitude, love, pride, or joy. But beneath these, there is the controlled regression, which interrupts verbal expression while the ego works through the earlier related conflicts,now remembered. The tearful feeling, a step in the direction of overt weeping, primitively expresses the frustration of an early wish for relief from pain, the pain of the imbalance of a complex conflict. The tearful feeling both expresses the wish for relief of pain and, at the same time, interrupts current verbal expression until the needed defense operations reduce the threat of ego disruption by working through old conflicts once again. Our thesis, then, is that within the analytic or psychotherapeutic hour the patient's feeling of tearfulness is a "too much" ego phenomenon that leads to a psychophysiological outlet.

  11. Polyphase exhumation in the western Qinling Mountains, China: Rapid Early Cretaceous cooling along a lithospheric-scale tear fault and pulsed Cenozoic uplift

    PubMed Central

    Heberer, Bianca; Anzenbacher, Thomas; Neubauer, Franz; Genser, Johann; Dong, Yunpeng; Dunkl, István

    2014-01-01

    The western sector of the Qinling–Dabie orogenic belt plays a key role in both Late Jurassic to Early Cretaceous “Yanshanian” intracontinental tectonics and Cenozoic lateral escape triggered by India–Asia collision. The Taibai granite in the northern Qinling Mountains is located at the westernmost tip of a Yanshanian granite belt. It consists of multiple intrusions, constrained by new Late Jurassic and Early Cretaceous U–Pb zircon ages (156 ± 3 Ma and 124 ± 1 Ma). Applying various geochronometers (40Ar/39Ar on hornblende, biotite and K-feldspar, apatite fission-track, apatite [U–Th–Sm]/He) along a vertical profile of the Taibai Mountain refines the cooling and exhumation history. The new age constraints record the prolonged pre-Cenozoic intracontinental deformation as well as the cooling history mostly related to India–Asia collision. We detected rapid cooling for the Taibai granite from ca. 800 to 100 °C during Early Cretaceous (ca. 123 to 100 Ma) followed by a period of slow cooling from ca. 100 Ma to ca. 25 Ma, and pulsed exhumation of the low-relief Cretaceous peneplain during Cenozoic times. We interpret the Early Cretaceous rapid cooling and exhumation as a result from activity along the southern sinistral lithospheric scale tear fault of the recently postulated intracontinental subduction of the Archean/Palaeoproterozoic North China Block beneath the Alashan Block. A Late Oligocene to Early Miocene cooling phase might be triggered either by the lateral motion during India–Asia collision and/or the Pacific subduction zone. Late Miocene intensified cooling is ascribed to uplift of the Tibetan Plateau. PMID:27065503

  12. Towards Multiscale Interactions Between Tearing Modes and Microturbulence

    NASA Astrophysics Data System (ADS)

    Williams, Z. R.; Pueschel, M. J.; Terry, P. W.

    2017-10-01

    Work on the Madison Symmetric Torus Reversed-Field Pinch (RFP) has shown that large-scale tearing modes present in standard operation are highly detrimental to confinement. These tearing modes, even when reduced in improved confinement regimes of operation, significantly affect zonal flow activity and play a large role in setting microturbulent-induced transport levels. Previous gyrokinetic work has shown that a small but finite tearing fluctuation amplitude is necessary to produce transport values in agreement with experimental observation. This has previously been implemented via an ad-hoc, constant-in-time A∥ perturbation. This work details self-consistent modeling of tearing fluctuations in the RFP using the Gene code via the inclusion of a current gradient drive incorporated into the background distribution function. Tearing mode growth rates calculated from gyrokinetic simulations are benchmarked with results from fluid theory. Additionally, first results from multiscale Gene simulations describing tearing mode interactions with RFP microturbulence are presented. This work is supported by the U.S. Department of Energy, Grant No. DE-FG02-85ER-53121.

  13. Comparison of Medpor coated tear drainage tube versus silicon tear drainage tube in conjunctivodacryocystorhinostomy: problems and solutions.

    PubMed

    Sendul, Selam Yekta; Cagatay, Halil Huseyin; Dirim, Burcu; Demir, Mehmet; Yıldız, Ali Atakhan; Acar, Zeynep; Cinar, Sonmez; Guven, Dilek

    2014-01-01

    This study aims at comparing two different types of drainage tubes in conjunctivodacryocystorhinostomy, which are used for upper lacrimal system obstruction or damage, with respect to their respective postoperative problems and solutions. Nineteen eyes of 17 patients who underwent conjunctivodacryocystorhinostomy (CDCR) or conjunctivorhinostomy (CR) surgery with a Medpor coated tear drainage tube or silicon tube placement between October, 2010, and February, 2014, were included in this retrospective comparative study. In the initial surgery, Medpor coated tear drainage tubes were used in 11 eyes by CDCR, whereas silicon tear drainage tubes were implanted into 2 eyes by CR and 6 eyes by CDCR. In group 1, proximal and distal obstructions developed postoperatively in 4 eyes, while 1 eye showed tube malposition and 3 eyes developed luminal obstruction by debris 3 times. In group 2, tube extrusion developed in 4 eyes, whereas tube malposition developed in 6 eyes and luminal obstruction by debris developed in 6 eyes at different times, for a total of 20 times. In our study, the most significant complication we observed in the use of silicon tear drainage tubes was tube extrusion,whereas the leading complication related to the use of Medpor coated tear drainage tubes was tube obstruction.

  14. Comparison of Medpor Coated Tear Drainage Tube versus Silicon Tear Drainage Tube in Conjunctivodacryocystorhinostomy: Problems and Solutions

    PubMed Central

    Sendul, Selam Yekta; Cagatay, Halil Huseyin; Dirim, Burcu; Demir, Mehmet; Yıldız, Ali Atakhan; Acar, Zeynep; Cinar, Sonmez; Guven, Dilek

    2014-01-01

    Purpose. This study aims at comparing two different types of drainage tubes in conjunctivodacryocystorhinostomy, which are used for upper lacrimal system obstruction or damage, with respect to their respective postoperative problems and solutions. Methods. Nineteen eyes of 17 patients who underwent conjunctivodacryocystorhinostomy (CDCR) or conjunctivorhinostomy (CR) surgery with a Medpor coated tear drainage tube or silicon tube placement between October, 2010, and February, 2014, were included in this retrospective comparative study. Results. In the initial surgery, Medpor coated tear drainage tubes were used in 11 eyes by CDCR, whereas silicon tear drainage tubes were implanted into 2 eyes by CR and 6 eyes by CDCR. In group 1, proximal and distal obstructions developed postoperatively in 4 eyes, while 1 eye showed tube malposition and 3 eyes developed luminal obstruction by debris 3 times. In group 2, tube extrusion developed in 4 eyes, whereas tube malposition developed in 6 eyes and luminal obstruction by debris developed in 6 eyes at different times, for a total of 20 times. Conclusions. In our study, the most significant complication we observed in the use of silicon tear drainage tubes was tube extrusion,whereas the leading complication related to the use of Medpor coated tear drainage tubes was tube obstruction. PMID:25379518

  15. [Effects of acupuncture on lactoferrin content in tears and tear secretion in patients suffering from dry eyes: a randomized controlled trial].

    PubMed

    Shi, Jing-lin; Miao, Wan-hong

    2012-09-01

    With the understanding of the immune inflammatory response in the pathogenesis of dry eyes, and the limitations of widely used artificial tears and numerous pharmaceuticals and methods to promote tear secretion, clinicians pay more attention to the therapies that can promote tear secretion actively. Acupuncture treatment for dry eye may meet this requirement. To observe the clinical efficacy of acupuncture treatment on dry eye and the effects on duration, and to examine the mechanisms of acupuncture in treating patients with dye eyes. The study was performed at Department of Ophthalmology, Shuguang Hospital, Shanghai University of Traditional Chinese Medicine from August 2010 to May 2011. Patients with the primary diagnosis of dry eye were enrolled. Sixty-five patients were randomly divided into treatment group and control group, and were given 3 weeks of acupuncture treatment or artificial tear therapy respectively. The enzyme-linked immunosorbent assay was used to detect the lactoferrin content of the tears before and after treatment. In order to evaluate the efficacy of the treatment methods, the Schirmer I test and break-up time were also measured. Compared with before treatment, the lactoferrin content in the tears of patients in the treatment group increased, break-up time was prolonged and the result of the Schirmer I test showed improvement after 3 weeks of treatment. The indexes mentioned above did not change in the control group after treatment. There were no significant differences in tear lactoferrin and Schirmer I test between one week after treatment and after 3-week treatment in the treatment group, but break-up time was significantly shortened. The result of Schirmer I test in the treatment group was significantly higher than that in the control group one week after treatment. Acupuncture can increase tear lactoferrin level, extend tear film break-up time and promote tear secretion in patients with dry eye in a time-limited trial. With the end of

  16. Fault rocks as indicators of slip behavior

    NASA Astrophysics Data System (ADS)

    Hayman, N. W.

    2017-12-01

    Forty years ago, Sibson ("Fault rocks and fault mechanisms", J. Geol. Soc. Lon., 1977) explored plastic flow mechanisms in the upper and lower crust which he attributed to deformation rates faster than tectonic ones, but slower than earthquakes. We can now combine observations of natural fault rocks with insights from experiments to interpret a broad range of length and time scales of fault slip in more detail. Fault rocks are generally weak, with predominantly frictionally stable materials in some fault segments, and more unstable materials in others. Both upper and lower crustal faults contain veins and mineralogical signatures of transiently elevated fluid pressure, and some contain relicts of pseudotachylite and bear other thermal-mechanical signatures of seismic slip. Varying strain rates and episodic-tremor-and-slip (ETS) have been attributed to fault zones with varying widths filled with irregular foliations, veins, and dismembered blocks of varying sizes. Particle-size distributions and orientations in gouge appear to differ between locked and creeping faults. These and other geologic observations can be framed in terms of constitutive behaviors derived from experiments and modeling. The experimental correlation of velocity-dependence with microstructure and the behavior of natural fault-rocks under shear suggest that friction laws may be applied liberally to fault-zone interpretation. Force-chains imaged in stress-sensitive granular aggregates or in numerical simulations show that stick-slip behavior with stress drops far below that of earthquakes can occur during quasi-periodic creep, yet localize shear in larger, aperiodic events; perhaps the systematic relationship between sub-mm shear bands and surrounding gouge and/or cataclasites causes such slip partitioning in nature. Fracture, frictional sliding, and viscous creep can experimentally produce a range of slip behavior, including ETS-like events. Perhaps a similar mechanism occurs to cause ETS at the

  17. Tear film measurement by optical reflectometry technique

    PubMed Central

    Lu, Hui; Wang, Michael R.; Wang, Jianhua; Shen, Meixiao

    2014-01-01

    Abstract. Evaluation of tear film is performed by an optical reflectometer system with alignment guided by a galvanometer scanner. The reflectometer system utilizes optical fibers to deliver illumination light to the tear film and collect the film reflectance as a function of wavelength. Film thickness is determined by best fitting the reflectance-wavelength curve. The spectral reflectance acquisition time is 15 ms, fast enough for detecting film thickness changes. Fast beam alignment of 1 s is achieved by the galvanometer scanner. The reflectometer was first used to evaluate artificial tear film on a model eye with and without a contact lens. The film thickness and thinning rate have been successfully quantified with the minimum measured thickness of about 0.3 μm. Tear films in human eyes, with and without a contact lens, have also been evaluated. A high-contrast spectral reflectance signal from the precontact lens tear film is clearly observed, and the thinning dynamics have been easily recorded from 3.69 to 1.31 μm with lipid layer thickness variation in the range of 41 to 67 nm. The accuracy of the measurement is better than ±0.58% of the film thickness at an estimated tear film refractive index error of ±0.001. The fiber-based reflectometer system is compact and easy to handle. PMID:24500519

  18. In vivo tear film thickness measurement and tear film dynamics visualization using spectral domain OCT and an efficient delay estimator

    NASA Astrophysics Data System (ADS)

    Aranha dos Santos, Valentin; Schmetterer, Leopold; Gröschl, Martin; Garhofer, Gerhard; Werkmeister, René M.

    2016-03-01

    Dry eye syndrome is a highly prevalent disease of the ocular surface characterized by an instability of the tear film. Traditional methods used for the evaluation of tear film stability are invasive or show limited repeatability. Here we propose a new noninvasive approach to measure tear film thickness using an efficient delay estimator and ultrahigh resolution spectral domain OCT. Silicon wafer phantoms with layers of known thickness and group index were used to validate the estimator-based thickness measurement. A theoretical analysis of the fundamental limit of the precision of the estimator is presented and the analytical expression of the Cramér-Rao lower bound (CRLB), which is the minimum variance that may be achieved by any unbiased estimator, is derived. The performance of the estimator against noise was investigated using simulations. We found that the proposed estimator reaches the CRLB associated with the OCT amplitude signal. The technique was applied in vivo in healthy subjects and dry eye patients. Series of tear film thickness maps were generated, allowing for the visualization of tear film dynamics. Our results show that the central tear film thickness precisely measured in vivo with a coefficient of variation of about 0.65% and that repeatable tear film dynamics can be observed. The presented method has the potential of being an alternative to breakup time measurements (BUT) and could be used in clinical setting to study patients with dry eye disease and monitor their treatments.

  19. Superior glenoid inclination and rotator cuff tears.

    PubMed

    Chalmers, Peter N; Beck, Lindsay; Granger, Erin; Henninger, Heath; Tashjian, Robert Z

    2018-03-23

    The objectives of this study were to determine whether glenoid inclination (1) could be measured accurately on magnetic resonance imaging (MRI) using computed tomography (CT) as a gold standard, (2) could be measured reliably on MRI, and (3) whether it differed between patients with rotator cuff tears and age-matched controls without evidence of rotator cuff tears or glenohumeral osteoarthritis. In this comparative retrospective radiographic study, we measured glenoid inclination on T1 coronal MRI corrected into the plane of the scapula. We determined accuracy by comparison with CT and inter-rater reliability. We compared glenoid inclination between patients with full-thickness rotator cuff tears and patients aged >50 years without evidence of a rotator cuff tear or glenohumeral arthritis. An a priori power analysis determined adequate power to detect a 2° difference in glenoid inclination. (1) In a validation cohort of 37 patients with MRI and CT, the intraclass correlation coefficient was 0.877, with a mean difference of 0° (95% confidence interval, -1° to 1°). (2) For MRI inclination, the inter-rater intraclass correlation coefficient was 0.911. (3) Superior glenoid inclination was 2° higher (range, 1°-4°, P < .001) in the rotator cuff tear group of 192 patients than in the control cohort of 107 patients. Glenoid inclination can be accurately and reliably measured on MRI. Although superior glenoid inclination is statistically greater in those with rotator cuff tears than in patients of similar age without rotator cuff tears or glenohumeral arthritis, the difference is likely below clinical significance. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  20. Frictional `non-aging' of fault mirror surfaces?: Insight from friction experiments on Carrara marble

    NASA Astrophysics Data System (ADS)

    Park, Y.; Ree, J. H.; Hirose, T.

    2016-12-01

    Mirror-like fault surfaces (or fault mirror: FM) have recently been suggested as a precursor of unstable slip (thus indicative of seismic slip). Frictional aging of fault surfaces (increase in static friction during interseismic period) is a common phenomenon of fault surfaces, resulting from increase in contact area or in bond strength between asperities with time. Despite the importance of FM in earthquake faulting, the frictional-aging behavior of FM has never been studied. To understand the frictional-aging behavior of FM, slide-hold-slide friction experiments were done on carbonate FM and powdered gouge of former carbonate FM (PG hereafter) using low-to-high-velocity-rotary-shear apparatus, at a slip rate of 1 μm s-1 a normal stress of 1.5 MPa, room temperature and room humidity condition. The sheared PG specimens showed a logarithmic positive relationship between static friction and holding time, consistent with Dieterich-type healing behavior. In contrast, the sheared FM specimens showed little effect of holding time on static friction. The slip surface of FM specimens consists of densely-packed and sintered nano-particles while that of PG specimens is composed of loose nano-particles. It has been known that yield strength of a material increases dramatically with size-decreasing grains being nano-particles. Since FM is a layer of densely-packed and sintered nanoparticles, enhanced strength of FM may inhibit growth of real contact area of fault surfaces during hold time. Furthermore, sintered particles composing FM have less pore space than loose gouge layer, and thus there would be a less chance of strengthening by pore space reduction, inter-particle meniscus formation or water adsorption onto the particles surface in the FM layer. Our preliminary result suggests that carbonate FM's may impede the recovery of fault strength during interseismic period, resulting in less possibility of earthquake nucleation. Reduced frictional healing may be a common

  1. Spectral-domain optical coherence tomography study on dynamic changes of human tears after instillation of artificial tears.

    PubMed

    Napoli, Pietro Emanuele; Satta, Giovanni Maria; Coronella, Franco; Fossarello, Maurizio

    2014-07-01

    To analyze in vivo the dynamic changes induced by different artificial tears (ATs) in the precorneal tear film (PCTF) and lower tear meniscus (LTM) by using spectral-domain (SD) anterior segment optical coherence tomography (OCT). We prospectively examined 42 normal human eyes by using SD-OCT imaging. On the day before OCT imaging, all enrolled subjects were evaluated for abnormalities of ocular surface. All tear film images were obtained before and after instillation of three different types of ATs (mucomimetic, lipid-based, and saline) in five serial scans: immediately (within 30 seconds), at the first, fifth, 10th, and 20th minute. Subjects received a drop of 35 μL in one randomly selected eye. All examinations were conducted in the same conditions of temperature, brightness, humidity, and time of day. Changes in the morphological pattern of both LTM and PCTF were associated with the type of artificial tear instilled on the ocular surface. Similarly, the radius of curvature (rc), the height (h), and the depth (d) showed dynamic variations depending on treatment. Although by the 20th minute, both h and d returned to baseline values in all groups, a significant difference in rc (compared with baseline) was detected for mucomimetic ATs (P = 0.04) and lipid ATs (P = 0.02). Spectral-domain OCT imaging has preliminarily proved to be a noninvasive tool to evaluate, in real time, the different changes induced by ATs instillation. An important stride in understanding the clinical response to various tear substitutes can be achieved by this objective and quantitative approach. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  2. Nonsurgical Treatment of Acetabular Labral Tears.

    PubMed

    Theige, Melissa; David, Shannon

    2018-05-04

    Clinical Scenario: Surgical treatment of acetabular labral tears has been explored in multiple studies, while there is a lack of research on the effectiveness of conservative methods. Focused Clinical Question: To what extent can nonsurgical treatment produce symptomatic or functional improvements in athletes with an acetabular labral tear? Summary of Search, Best Evidence Appraised, and Key Findings: The literature was searched for studies of patients with confirmed acetabular labral tears who participated in any level of sport. Four studies were located, all of which were included. Clinical Bottom Line: The research discussed in this review agreed that conservative management of acetabular labral tears produced measurable improvements in pain and function among the athletes studied, including their ability to participate in sport activities. Based on these findings, it appears that conservative management is effective at rehabilitating athletes with acetabular labral tears. However, this method should not be applied to every athlete based on the low strength of current research. Treatment plans should be decided upon on a case-by-case basis. Strength of Recommendation: The studies located were of low quality. The highest Oxford Center for Evidence-Based Medicine Level of Evidence achieved was 4. Higher level studies must be conducted before the conclusions of this research can be applied clinically with assertion. Strength of recommendation is level 3.

  3. Fault creep and persistent asperities on the western section of the North Anatolian Fault, Turkey

    NASA Astrophysics Data System (ADS)

    Floyd, M.; Reilinger, R. E.; Ergintav, S.; Karabulut, H.; Vernant, P.; Konca, A. O.; Dogan, U.; Cetin, S.; Cakir, Z.; Mencin, D.; Bilham, R. G.; King, R. W.

    2017-12-01

    1939, 1942 and 1943, suggests that deep fault healing is complete over time scales much shorter than the earthquake repeat time. Given their similarities, these results may be applicable and provide insights into the mechanics of strain accumulation and earthquake potential along other continental strike-slip faults such as the San Andreas Fault.

  4. Posterior meniscus root tears: associated pathologies to assist as diagnostic tools.

    PubMed

    Matheny, Lauren M; Ockuly, Andrew C; Steadman, J Richard; LaPrade, Robert F

    2015-10-01

    The purpose of this study was to investigate associated pathologies identified at arthroscopy in patients with meniscus root tears. This study was Institutional Review Board approved. All patients who underwent arthroscopic knee surgery where a complete meniscus root tear was identified were included in this study. Concurrent ligament tears and articular cartilage changes ≥Outerbridge grade 2 were recorded and stored in a data registry. Fifty patients (28 males, 22 females) [mean age = 36.5 years (range 17.1-68.1 years)] who were diagnosed with a medial or lateral meniscus root tear at arthroscopy were included in this study out of 673 arthroscopic surgeries (prevalence 7.4 %). Twenty-three (46 %) patients had a medial meniscus root tear, 26 (52 %) patients had a lateral meniscus root tear and one (2 %) patient had both. Thirty-four per cent of patients (n = 17) underwent partial meniscectomy, while 60 % (n = 31) underwent suture repair. During arthroscopy, 60 % (n = 30) of patients were diagnosed with an anterior cruciate ligament (ACL) tear. Patients with lateral meniscus root tears were 10.3 times (95 % CI 2.6-42.5) more likely to have ACL tears than patients with medial meniscus root tears (p = 0.012). Patients who had medial meniscus root tears were 5.8 times (95 % CI 1.6-20.5) more likely to have chondral defects than patients who had lateral meniscus root tears (p = 0.044). In this study, patients' preoperative functional scores and activity levels were low. Patients with lateral meniscal root tears were more likely to have an ACL tear. Patients with medial meniscal root tears were more likely to have an knee articular cartilage defect with an Outerbridge grade 2 or higher chondral defect. This study confirms the importance of comprehensive assessment of concurrent injuries to properly diagnose meniscus root tears. IV.

  5. Comparison of GPS and Quaternary slip rates: Insights from a new Quaternary fault database for Central Asia

    NASA Astrophysics Data System (ADS)

    Mohadjer, Solmaz; Ehlers, Todd; Bendick, Rebecca; Mutz, Sebastian

    2016-04-01

    Previous studies related to the kinematics of deformation within the India-Asia collision zone have relied on slip rate data for major active faults to test kinematic models that explain the deformation of the region. The slip rate data, however, are generally disputed for many of the first-order faults in the region (e.g., Altyn Tagh and Karakorum faults). Several studies have also challenged the common assumption that geodetic slip rates are representative of Quaternary slip rates. What has received little attention is the degree to which geodetic slip rates relate to Quaternary slip rates for active faults in the India-Asia collision zone. In this study, we utilize slip rate data from a new Quaternary fault database for Central Asia to determine the overall relationship between Quaternary and GPS-derived slip rates for 18 faults. The preliminary analysis investigating this relationship uses weighted least squares and a re-sampling analysis to test the sensitivity of this relationship to different data point attributes (e.g., faults associated with data points and dating methods used for estimating Quaternary slip rates). The resulting sample subsets of data points yield a maximum possible Pearson correlation coefficient of ~0.6, suggesting moderate correlation between Quaternary and GPS-derived slip rates for some faults (e.g., Kunlun and Longmen Shan faults). Faults with poorly correlated Quaternary and GPS-derived slip rates were identified and dating methods used for the Quaternary slip rates were examined. Results indicate that a poor correlation between Quaternary and GPS-derived slip rates exist for the Karakorum and Chaman faults. Large differences between Quaternary and GPS slip rates for these faults appear to be connected to qualitative dating of landforms used in the estimation of the Quaternary slip rates and errors in the geomorphic and structural reconstruction of offset landforms (e.g., offset terrace riser reconstructions for Altyn Tagh fault

  6. Patient acceptability of tear collection in the primary healthcare setting.

    PubMed

    Quah, Joanne Hui Min; Tong, Louis; Barbier, Sylvaine

    2014-04-01

    The primary healthcare setting is well placed for health screening. Tear fluid composition gives valuable information about the eye and systemic health, and there is now significant interest in the potential application of tears as a tool for health screening; however, the acceptability of tear collection in the primary healthcare setting as compared with other methods of human sample collection has not been previously addressed. The objective of this study was to evaluate the patient acceptability of tear collection in a primary healthcare setting. This was a cross-sectional study on 383 adult patients seeking primary healthcare, who were not diabetic and were not attending for an eye-related complaint. Tear collection was done using Schirmer strips, and an interviewer-administered questionnaire was conducted to collate information on the pain score (0-10) of the Schirmer tear collection, as well as to score the pain associated with their previous experience of antecubital venous puncture and finger prick test. The pain score for Schirmer tear collection was significantly lower (p < 0.001) than antecubital venous puncture but higher (p < 0.001) than finger prick. The pain scores for all three procedures were significantly higher in participants of younger age, female gender, and higher education level. Among the participants, 70% did not mind their tears being collected to screen for eye problems, whereas only 38% did not mind this procedure being performed for general health screening. Nevertheless, 69% of the participants preferred tear to urine collection, and 74% of participants preferred tear to blood collection. Tear collection using Schirmer strips is a highly acceptable form of investigation that has the potential for use in health screening in the primary healthcare setting. This study has implications on using tear collection as a method of ocular and systemic health screening in the primary healthcare setting.

  7. Retinal tear: an unusual complication of ocular toxoplasmosis.

    PubMed

    Celebi, Ali Riza Cenk; Kilavuzoglu, Ayse Ebru; Altiparmak, Ugur Emrah; Cosar, Cemile Banu; Ozkiris, Abdullah

    2015-01-01

    It is aimed to report on a 16-year-old patient with acquired ocular toxoplasmosis complicated by a retinal tear. Retrospective medical chart review. A 16-year-old Caucasian female presented with vision loss in her right eye. In addition to a white active lesion between the fovea and the optic nerve head, marked vitreous opacification was noted. She was diagnosed with ocular toxoplasmosis. The patient was treated with oral azithromycin, clindamycin, and trimethoprimsulfamethoxazole. One month later, retinochoroiditis resolved and vitreous cleared. Three months after onset, patient presented with floaters in the right eye and a retinal tear was located at the temporal region of the retina. Prophylactic argon laser treatment that encircled the retinal tear was performed. No other abnormalities were noted during 6 months of follow-up. Retinal tear associated with ocular toxoplasmosis is rare; however, a retinal tear can occur due to vitreoretinal traction following post-inflammatory structural alteration of the vitreous. Retinal tears may be seen during the healing phase, when the inflammation turns into tightening of vitreous substance. Careful retinal examination in cases of ocular toxoplasmosis is warranted, especially in patients with severe vitreous inflammation.

  8. Geometry and kinematics of accretionary wedge faults inherited from the structure and rheology of the incoming sedimentary section; insights from 3D seismic reflection data

    NASA Astrophysics Data System (ADS)

    Bell, Rebecca; Orme, Haydn; Lenette, Kathryn; Jackson, Christopher; Fitch, Peter; Phillips, Thomas; Moore, Gregory

    2017-04-01

    -circular seamounts. The youngest, most basinward thrusts in the wedge strike NW-SE; however, 17 km landward, towards the wedge core, they strike NE-SW. The orientation of the more landward faults correlates with the trend of linear basement relief, whereas thrust fault orientations close to the deformation front are perpendicular to the convergence direction. We notice that oceanic crust that has been subducted is characterised by NE-SW striking, now-inverted normal faults, with some faults extending up through the entire sedimentary section. We suggest that the NE-SW orientation of thrust faults has been inherited from linear basement ridges. In contrast, basement currently subducting beneath the deformation front is dominated by seamounts and is devoid of more linear features. Here, there are no pre-existing normal faults available for reactivation and thrust faults develop perpendicular to the convergence direction. We show that the incoming plate properties have a profound effect on the geometry of accretionary wedges; it would be difficult to elucidate this without 3D seismic data. Our insights provide new hypotheses that can be tested with numerical and laboratory models.

  9. Forced tearing of ductile and brittle thin sheets.

    PubMed

    Tallinen, T; Mahadevan, L

    2011-12-09

    Tearing a thin sheet by forcing a rigid object through it leads to complex crack morphologies; a single oscillatory crack arises when a tool is driven laterally through a brittle sheet, while two diverging cracks and a series of concertinalike folds forms when a tool is forced laterally through a ductile sheet. On the other hand, forcing an object perpendicularly through the sheet leads to radial petallike tears in both ductile and brittle materials. To understand these different regimes we use a combination of experiments, simulations, and simple theories. In particular, we describe the transition from brittle oscillatory tearing via a single crack to ductile concertina tearing with two tears by deriving laws that describe the crack paths and wavelength of the concertina folds and provide a simple phase diagram for the morphologies in terms of the material properties of the sheet and the relative size of the tool.

  10. Assessment and treatment strategies for rotator cuff tears

    PubMed Central

    Al-Hakim, Wisam; Noorani, Ali

    2014-01-01

    Tears of the rotator cuff are common and becoming an increasingly frequent problem. There is a vast amount of literature on the merits and limitations of the various methods of clinical and radiological assessment of rotator cuff tears. This is also the case with regard to treatment strategies. Certain popular beliefs and principles practiced widely and the basis upon which they are derived may be prone to inaccuracy. We provide an overview of the historical management of rotator cuff tears, as well as an explanation for how and why rotator cuff tears should be managed, and propose a structured methodology for their assessment and treatment. PMID:27582960

  11. Superior labrum anterior to posterior tears and glenohumeral instability.

    PubMed

    Virk, Mandeep S; Arciero, Robert A

    2013-01-01

    Cadaver experiments and clinical studies suggest that the superior labrum-biceps complex plays a role in glenohumeral stability. Superior labrum anterior to posterior (SLAP) tears can be present in acute and recurrent glenohumeral dislocations and contribute to glenohumeral instability. Isolated SLAP tears can cause instability, especially in throwing athletes. Diagnosing a SLAP tear on the basis of the clinical examination alone is difficult because of nonspecific history and physical examination findings and the presence of coexisting intra-articular lesions. Magnetic resonance arthrography is the imaging study of choice for diagnosing SLAP tears; however, arthroscopy remains the gold standard for diagnosis. Arthroscopy is the preferred technique for the repair of a type II SLAP tear and its variant types (V through X) in acute glenohumeral dislocations and instability in younger populations. Clinical outcome studies report a low recurrence of glenohumeral instability after the arthroscopic repair of a SLAP tear in addition to a Bankart repair. Long-term follow-up studies and further advances in arthroscopic fixation techniques will allow a better understanding and improvement in outcomes in patients with SLAP tears associated with glenohumeral instability.

  12. Rotator cuff tear measurement by arthropneumotomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kilcoyne, R.F.; Matsen, F.A. III

    1983-02-01

    Five years of experience with a method of shoulder arthrography using upright tomography in cases of suspected or known rotator cuff tears has demonstrated its effectiveness. The value of the procedure lies in its ability to demonstrate the size of the cuff tear and the thickness of the remaining cuff tissue. This information provides the surgeon with a preoperative estimate of the difficulty of the repair and the prognosis for a good functional recovery. In 33 cases, there was good correlation between the upright thin-section tomogram findings and the surgical results. The tomograms provided better information about the size ofmore » the tear and the quality of the remaining cuff than did plain arthrograms.« less

  13. The prevalence of rotator cuff tears: is the contralateral shoulder at risk?

    PubMed

    Liem, Dennis; Buschmann, Vera Elisa; Schmidt, Carolin; Gosheger, Georg; Vogler, Tim; Schulte, Tobias L; Balke, Maurice

    2014-04-01

    Rotator cuff tears are a common cause of pain and disability of the shoulder. Information on the prevalence and identification of potential risk factors could help in early detection of rotator cuff tears and improve treatment outcome. Patients treated for a symptomatic rotator cuff tear on one side have a higher prevalence of rotator cuff tears and decreased shoulder function on the contralateral side compared with an age- and sex-matched group of healthy individuals. Case control study; Level of evidence, 3. One group consisted of 55 patients who had been arthroscopically treated on one shoulder for rotator cuff tear (tear group). In this group, the nonoperated contralateral shoulder was examined. For comparison, the matching shoulder in a control group consisting of 55 subjectively healthy individuals matched by age (±1 year) and sex to the tear group was included. Diagnosis of a rotator cuff tear was made by ultrasound. Outcomes were measured using the Constant score. The prevalence of supraspinatus tears was significantly higher (P < .0001) in the tear group (67.3%) compared with the control group (11.0%). The Constant score for the activities of daily living subscale, however, was significantly lower (18.4) in the tear group compared with the control group (19.9; P = .012). No other subcategory score nor the overall score showed a significant difference. There was a significantly higher tear prevalence in the tear group of patients aged between 50 and 59 years (P < .001) and 60 and 69 years (P = .004). No tear was diagnosed in the control group in individuals younger than 60 years. Patients treated for partial and full-thickness rotator cuff tears have a significantly higher risk of having a tear on the contralateral side and have noticeable deficits in their shoulder function regarding activities of daily living even if the tear is otherwise asymptomatic.

  14. Partial Thickness Rotator Cuff Tears: Current Concepts

    PubMed Central

    Matthewson, Graeme; Beach, Cara J.; Nelson, Atiba A.; Woodmass, Jarret M.; Ono, Yohei; Boorman, Richard S.; Lo, Ian K. Y.; Thornton, Gail M.

    2015-01-01

    Partial thickness rotator cuff tears are a common cause of pain in the adult shoulder. Despite their high prevalence, the diagnosis and treatment of partial thickness rotator cuff tears remains controversial. While recent studies have helped to elucidate the anatomy and natural history of disease progression, the optimal treatment, both nonoperative and operative, is unclear. Although the advent of arthroscopy has improved the accuracy of the diagnosis of partial thickness rotator cuff tears, the number of surgical techniques used to repair these tears has also increased. While multiple repair techniques have been described, there is currently no significant clinical evidence supporting more complex surgical techniques over standard rotator cuff repair. Further research is required to determine the clinical indications for surgical and nonsurgical management, when formal rotator cuff repair is specifically indicated and when biologic adjunctive therapy may be utilized. PMID:26171251

  15. Global strike-slip fault distribution on Enceladus reveals mostly left-lateral faults

    NASA Astrophysics Data System (ADS)

    Martin, E. S.; Kattenhorn, S. A.

    2013-12-01

    the SPT is devoid of shear: previous work has indicated that the tiger stripes may be undergoing strike-slip motions and the surrounding regions may be experiencing shear. The fracture patterns and geologic activity within the SPT have been previously documented to be the result of stresses induced by both NSR and diurnal tidal deformation. As these same mechanisms are the main controls on strike-slip fault patterns on Europa, the lack of a match between strike-slip patterns on Europa and Enceladus is intriguing. The pattern of strike-slip faults on Enceladus suggests a different combination of stress mechanisms is required to produce the observed distributions. We will present models of global stress mechanisms to consider how the global-scale pattern of strike-slip faults on Enceladus may have been produced. This problem will be investigated further by measuring the angles at which tailcracks have formed on Enceladus. Tailcracks produced by simple shear form at 70.5° to the fault. Any deviation from this angle indicates some ratio of concomitant shear and dilation, which may provide insights into elucidating the stresses controlling strike-slip formation on Enceladus.

  16. The influence of normal fault geometry on porous sandstone deformation: Insights from mechanical models into conditions leading to Coulomb failure and shear-enhanced compaction

    NASA Astrophysics Data System (ADS)

    Allison, K.; Reinen, L. A.

    2011-12-01

    Slip on non-planar faults produces stress perturbations in the surrounding host rock that can yield secondary faults at a scale too small to be resolved on seismic surveys. Porosity changes during failure may affect the ability of the rock to transmit fluids through dilatant cracking or, in porous rocks, shear-enhanced compaction (i.e., cataclastic flow). Modeling the mechanical behavior of the host rock in response to slip on non-planar faults can yield insights into the role of fault geometry on regions of enhanced or inhibited fluid flow. To evaluate the effect of normal fault geometry on deformation in porous sandstones, we model the system as a linear elastic, homogeneous, whole or half space using the boundary-element modeling program Poly3D. We consider conditions leading to secondary deformation using the maximum Coulomb shear stress (MCSS) as an index of brittle deformation and proximity to an elliptical yield envelope (Y), determined experimentally for porous sandstone (Baud et al., JGR, 2006), for cataclastic flow. We model rectangular faults consisting of two segments: an upper leg with a constant dip of 60° and a lower leg with dips ranging 15-85°. We explore far-field stress models of constant and gradient uniaxial strain. We investigate the potential damage in the host rock in two ways: [1] the size of the damage zone, and [2] regions of enhanced deformation indicated by elevated MCSS or Y. Preliminary results indicate that, along a vertical transect passing through the fault kink, [1] the size of the damage zone increases in the footwall with increasing lower leg dip and remains constant in the hanging wall. [2] In the footwall, the amount of deformation does not change as a function of lower leg dip in constant stress models; in gradient stress models, both MCSS and Y increase with dip. In the hanging wall, Y decreases with increasing lower leg dip for both constant and gradient stress models. In contrast, MCSS increases: as lower leg dip

  17. MR imaging of the traumatic triangular fibrocartilaginous complex tear

    PubMed Central

    Griffith, James F.; Fung, Cindy S. Y.; Lee, Ryan K. L.; Tong, Cina S. L.; Wong, Clara W. Y.; Tse, Wing Lim; Ho, Pak Cheong

    2017-01-01

    Triangular fibrocartilage complex is a major stabilizer of the distal radioulnar joint (DRUJ). However, triangular fibrocartilage complex (TFCC) tear is difficult to be diagnosed on MRI for its intrinsic small and thin structure with complex anatomy. The purpose of this article is to review the anatomy of TFCC, state of art MRI imaging technique, normal appearance and features of tear on MRI according to the Palmar’s classification. Atypical tear and limitations of MRI in diagnosis of TFCC tear are also discussed. PMID:28932701

  18. Ocular Pharmacology of Tear Film, Dry Eye, and Allergic Conjunctivitis.

    PubMed

    Gulati, Shilpa; Jain, Sandeep

    2017-01-01

    Dry Eye Disease (DED) is "a multifactorial disease of the tears and ocular surface that results in symptoms of discomfort, visual disturbance, and tear-film instability with potential damage to the ocular surface." DED comprises two etiologic categories: aqueous-deficient dry eye (ADDE) and evaporative dry eye (EDE). Diagnostic workup of DED should include clinical history, symptom questionnaire, fluorescein TBUT, ocular surface staining grading, Schirmer I/II, lid and meibomian pathology, meibomian expression, followed by other available tests. New diagnostic tests employ the Oculus Keratograph, which performs non-invasive tear-film analysis and a bulbar redness (BR). The TearLab Osmolarity Test enables rapid clinical evaluation of tear osmolarity. Lipiview is a recently developed diagnostic tool that uses interferometry to quantitatively evaluate tear-film thickness. In DED, epithelial and inflammatory cells produce a variety of inflammatory mediators. A stagnant tear film and decreased concentration of mucin result in the accumulation of inflammatory factors that can penetrate tight junctions and cause epithelial cell death. DED treatment algorithms are based on severity of clinical signs and symptoms, and disease etiology. Therapeutic approaches include lubricating artificial tears and immunomodulatory agents.

  19. [The peroxidase content of human tears].

    PubMed

    Buchberger, W; Rieger, G

    1989-01-01

    The peroxidase-(POD)-thiocyanate-hydrogenperoxide-system is a well-known antibacterial system, which has been demonstrated to exist, for example, in milk and saliva. Earlier investigations by van Haeringen et al. established a POD level in human tears of 10(3) units/l, yet the thiocyanate concentration was only about 0.2 mmol/l. Therefore van Haeringen et al. excluded the existence of a POD-thiocyanate-hydrogenperoxide antibacterial system in human tears because of the insufficient amount of thiocyanate in the tears examined. Instead of thiocyanate halides such as J- can also complete the POD hydrogen peroxide system as electron donors. Sufficient amounts of iodide can be expected after the application of iodine-containing eye drops or after local treatment with iodine-containing brine, as done in Bad Hall in Austria. Therefore, the above mentioned antibacterial system may be of importance if the POD-level is high enough (greater than 250 units/l). We investigated 22 tear samples from healthy persons: the POD levels were below 20 units/l in 19 cases; in 3 cases the POD concentration was found to be between 20 and 50 units/l. Therefore, in normal human tear fluid, not only the amount of thiocyanate but also the concentration of POD is too low for effective antimicrobial activity of the peroxidase-thiocyanate-hydrogenperoxide system. It is so far not known whether this system is effective under pathological conditions.

  20. Asymptomatic rotator cuff tears: Patient demographics and baseline shoulder function

    PubMed Central

    Keener, Jay D.; Steger-May, Karen; Stobbs, Georgia; Yamaguchi, Ken

    2010-01-01

    Background The purpose of this study is to characterize the demographic features and physical function of subjects with asymptomatic rotator cuff tears and to compare their shoulder function to controls with an intact rotator cuff. Materials and Methods 196 subjects with an asymptomatic rotator cuff tear and 54 subjects with an intact rotator cuff presenting with a painful rotator cuff tear in the contralateral shoulder were enrolled. Various demographic features, shoulder function (ASES score and SST score), range of motion and strength were compared. Results The demographic features of the study and control groups were similar. Hand dominance was associated with the presence of shoulder pain (p < .05). Subjects with an intact rotator cuff had greater but clinically insignificant ASES (p < .05) and SST scores (p < .05) than those with an asymptomatic tear. No differences in functional scores, range of motion or strength were seen between partial (n=61) and full-thickness tears (n=135). Of the full-thickness tears, 36 (27%) were classified as small, 85 (63%) as medium and 14 (10%) as large tears. No differences were seen in functional scores between full-thickness tears of various sizes. Conclusions When asymptomatic, a rotator cuff tear is associated with a clinically insignificant loss of shoulder function compared to those with an intact rotator cuff. Therefore, a clinically detectable decline in shoulder function may indicate an “at-risk” asymptomatic tear. The presence of pain is important in cuff deficient shoulders for creating a measurable loss of shoulder function. Hand dominance appears to be an important risk factor for pain. PMID:21030274

  1. Interaction between fault systems in a complex tectonic setting: Insights from InSAR and Teleseismic analysis of the 2015 Lake Saurez and 2016 Muji fault earthquake sequence

    NASA Astrophysics Data System (ADS)

    Nanjundiah, P.; Barbot, S.; Wei, S.; Tapponnier, P.; Feng, W.; Wang, T.

    2017-12-01

    The Pamir Plateau is a complex and important component of the India-Eurasia Collision zone. Despite being similar to the Tibetan plateau in elevation and collision processes, quite a bit is still unknown about the structure and the tectonic processes occurring in this region. We aim to better understand the structure, stress and deformation patterns in the northern and central Pamir plateau by analysing InSAR, teleseismic, and optical data for two large earthquakes that occurred in this region between December 2015 (Mw 7.2, Lake Saurez) and November 2016 (Mw 6.6 Muji Fault). We constrain the fault geometry by precisely relocating aftershocks using the double difference technique implemented in HypoDD (Waldhauser & Ellsworth 2000). We used Okada's (1992) Green Functions to invert for slip on the fault with a rectangular dislocation and edgreen to numerically invert for the slip in a layered medium (Wang et al. 2005). The combined datasets highlight the existence of an oblique fault between two major thrust fault systems i.e. the Darwas & the Karakoram faults. The December 2015 event highlights complexity in this fault system. The combination of data sets used in this study highlights the existence of a seismic gap south of Lake Karakul as well as coupling between the Muji and Darwas-Karakoram fault systems. We emphasise the role of smaller faults and their interactions in accommodating the overall strain and tectonics in the Pamir region and their effect on estimating local seismic hazard.

  2. Cemental tear: To know what we have neglected in dental practice.

    PubMed

    Jeng, Po-Yuan; Luzi, Arlinda Luzi; Pitarch, Rocio Marco; Chang, Mei-Chi; Wu, Yu-Hsueh; Jeng, Jiiang-Huei

    2018-04-01

    Cemental tear is a special kind of root surface fracture, contributing to periodontal and periapical breakdown. However, it is a challenge for doctors to diagnose, resulting in delayed or improper treatment. We reviewed the predisposing factors, location, radiographic/clinical characteristics, diagnosis and treatments of cemental tears. From the literature, patients with cemental tear were mainly males, over 60 year-old. Possible predisposing factors include gender, age, tooth type, traumatic occlusal force and vital teeth. Cemental tears were common in upper and lower anterior teeth, single or multiple, and can be present in cervical, middle and apical third of roots. Morphology of cemental tears can be either piece-shaped or U-shaped. Clinically, cemental tear shows a unitary periodontal pocket and signs/symptoms mimicking localized periodontitis, apical periodontitis and vertical root fractures. Treatment of cemental tears include scaling, root planning, root canal treatment, periodontal/periapical surgery, guided tissue regeneration, bone grafting, and intentional replantation. Recurrence of cemental tear is possible especially when the fracture involves root apex. Extraction is recommended for teeth with poor prognosis. In conclusion, cemental tears can involve both periodontal and periapical area. Dentists should understand the predisposing factors and clinical features of cemental tears for early diagnosis/treatment to prevent bone loss/tooth extraction. Copyright © 2017. Published by Elsevier B.V.

  3. Overview of the Southern San Andreas Fault Model

    USGS Publications Warehouse

    Weldon, Ray J.; Biasi, Glenn P.; Wills, Chris J.; Dawson, Timothy E.

    2008-01-01

    This appendix summarizes the data and methodology used to generate the source model for the southern San Andreas fault. It is organized into three sections, 1) a section by section review of the geological data in the format of past Working Groups, 2) an overview of the rupture model, and 3) a manuscript by Biasi and Weldon (in review Bulletin of the Seismological Society of America) that describes the correlation methodology that was used to help develop the ?geologic insight? model. The goal of the Biasi and Weldon methodology is to quantify the insight that went into developing all A faults; as such it is in concept consistent with all other A faults but applied in a more quantitative way. The most rapidly slipping fault and the only known source of M~8 earthquakes in southern California is the San Andreas fault. As such it plays a special role in the seismic hazard of California, and has received special attention in the current Working Group. The underlying philosophy of the current Working Group is to model the recurrence behavior of large, rapidly slipping faults like the San Andreas from observed data on the size, distribution and timing of past earthquakes with as few assumptions about underlying recurrence behavior as possible. In addition, we wish to carry the uncertainties in the data and the range of reasonable extrapolations from the data to the final model. To accomplish this for the Southern San Andreas fault we have developed an objective method to combine all of the observations of size, timing, and distribution of past earthquakes into a comprehensive set of earthquake scenarios that each represent a possible history of earthquakes for the past ~1400 years. The scenarios are then ranked according to their overall consistency with the data and then the frequencies of all of the ruptures permitted by the current Working Group?s segmentation model are calculated. We also present 30-yr conditional probabilities by segment and compare to previous

  4. The Intersection between the Gloria Transform Fault and the Tore-Madeira Rise in the NE Atlantic: New Tectonic Insights from Analog Modeling Results

    NASA Astrophysics Data System (ADS)

    Rosas, F. M.; Tomas, R.; Duarte, J. C.; Schellart, W. P.; Terrinha, P.

    2014-12-01

    The intersection between the Gloria Fault (GF) and the Tore-Madeira rise (TMR) in NE Atlantic marks a transition from a discrete to a diffuse nature along a critical segment of the Eurasia/Africa plate boundary. To the West of such intersection, approximately since the Azores triple junction, this plate boundary is mostly characterized by a set of closely aligned and continuous strike-slip faults that make up the narrow active dextral transcurrent system of the GF (with high magnitude M>7 historical earthquakes). While intersecting the TMR the closely E-W trending trace of the GF system is slightly deflected (changing to WNW-ESE), and splays into several fault branches that often coincide with aligned (TMR related?) active volcanic plugs. The segment of the plate boundary between the TMR and the Gorringe Bank (further to the East) corresponds to a more complex (less discrete) tectonic configuration, within which the tectonic connection between the Gloria Fault and another major dextral transcurrent system (the so called SWIM system) occurs. This SWIM fault system has been described to extend even further to the East (almost until the Straits of Gibraltar) across the Gulf of Cadiz domain. In this domain the relative movement between the Eurasian and the African plates is thought to be accommodated through a diffuse manner, involving large scale strain partition between a dextral transcurrent fault-system (the SWIM system), and a set of active west-directed én-échelon major thrusts extending to the North along the SW Iberian margin. We present new analog modeling results, in which we employed different experimental settings to address (namely) the following main questions (as a first step to gain new insight on the tectonic evolution of the TRM-GF critical intersection area): Could the observed morphotectonic configuration of such intersection be simply caused by a bathymetric anomaly determined by a postulated thickened oceanic crust, or is it more compatible with

  5. Isotretinoin in lacrimal gland fluid and tears.

    PubMed

    Rismondo, V; Ubels, J L

    1987-03-01

    Isotretinoin (13-cis-retinoic acid) is used in the treatment of severe cystic acne. Adverse ocular reactions, including blepharoconjunctivitis and dry eye symptoms, are frequent side effects of this drug. Our previous observation that retinol is present in tears and lacrimal gland fluid suggests that isotretinoin may also be secreted by the lacrimal gland. Rabbits were treated with isotretinoin, and lacrimal gland fluid was collected from the cannulated lacrimal gland duct. Tears were collected from patients who were being treated with isotretinoin. Lacrimal gland fluid and tears were analyzed by reverse-phase high-pressure liquid chromatography and a peak eluted from each sample, which was identified as isotretinoin. We conclude that the lacrimal gland is able to secrete isotretinoin in addition to retinol and that, in animals and patients treated systemically with isotretinoin, the ocular surface is exposed to the drug via the tear film.

  6. Comparison of camel tear proteins between summer and winter

    PubMed Central

    Chen, Ziyan; Shamsi, Farrukh A.; Li, Kaijun; Huang, Qiang; Al-Rajhi, Ali A.; Chaudhry, Imtiaz A.

    2011-01-01

    Purpose Proteins in the tear fluid have positive effects on maintaining the integrity and stabilization of the tear film, which is affected by several environmental factors. The aim of this study is to investigate seasonal variation of protein patterns in camel tears collected during the summer and winter season. Methods Tears from both eyes of 50 clinically normal camels (Camelus dromedarius) were collected in the summer (June – July) and in the winter (December – January) respectively. Pooled tear protein samples from two seasons were separated by SDS–PAGE and two-dimensional electrophoresis (2-DE). Protein spots of differential expression in two season gels were excised and subjected to in-gel digestion and identification by matrix assisted laser desorption/ionization-time of flight/time of flight-mass spectrum (MALDI-TOF/TOF-MS) analysis. Two differentially expressed proteins, lactoferrin (LF) and vitelline membrane outer layer protein 1 homolog (VMO1 homolog), were validated by western blotting. Results Thirteen well resolved bands were detected in SDS–PAGE gels of both summer and winter camel tears. By band densitometry, significantly higher intensities of band 6, 7, 11, and lower intensity of band 13 were observed in the summer group compared to the winter group. In 2-DE profiles of camel tears, four protein spots were found expressed differentially in two seasons. Further protein identification by MALDI-TOF/TOF-MS and confirmation by western blotting indicated that there was a significant decrease in LF (p=0.002) and an increase in VMO1 homolog (p=0.042) in tears in the summer compared to the winter. Conclusions The seasonal variation of camel tear fluids has been found in the composition of proteins, including LF and VMO1 homolog. This result will expand our knowledge of physiologic characteristics of tear fluids and establish a foundation for the mechanistic studies and clinical practices on ocular surface disorders. PMID:21293736

  7. Hip Labral Tear

    MedlinePlus

    ... participate in such sports as ice hockey, soccer, football, golf and ballet are at higher risk of ... accidents or from playing contact sports such as football or hockey — can cause a hip labral tear. ...

  8. Does a critical rotator cuff tear stage exist?: a biomechanical study of rotator cuff tear progression in human cadaver shoulders.

    PubMed

    Oh, Joo Han; Jun, Bong Jae; McGarry, Michelle H; Lee, Thay Q

    2011-11-16

    It is unknown at which stage of rotator cuff tear the biomechanical environment is altered. The purpose of this study was to determine if a critical rotator cuff tear stage exists that alters glenohumeral joint biomechanics throughout the rotational range of shoulder motion, and to evaluate the biomechanical effect of parascapular muscle-loading. Eight cadaver shoulders were used with a custom testing system. Four progressive rotator cuff tear stages were investigated on the basis of footprint anatomy. Three muscle-loading conditions were examined: rotator cuff only; rotator cuff with deltoid muscle; and rotator cuff, deltoid, pectoralis major, and latissimus dorsi muscles. Testing was performed in the scapular plane with 0°, 30°, and 60° of shoulder abduction. The maximum internal and external rotations were measured with 3.4 Nm of torque. The position of the humeral head apex with respect to the glenoid was calculated with use of a MicroScribe 3DLX digitizing system throughout the rotational range of motion. The abduction capability was determined as the abduction angle achieved with increasing deltoid load. Tear of the entire supraspinatus tendon significantly increased maximum external rotation and significantly decreased abduction capability with higher deltoid loads (p < 0.05). Tear of the entire supraspinatus tendon and half of the infraspinatus tendon significantly shifted the humeral head apex posteriorly at the midrange of rotation and superiorly at maximum internal rotation (p < 0.05). Loading the pectoralis major and latissimus dorsi muscles decreased the amount of humeral head elevation due to deltoid loading. Tear of the entire supraspinatus tendon was the critical stage for increasing rotational range of shoulder motion and for decreased abduction capability. Further tear progression to the infraspinatus muscle was the critical stage for significant changes in humeral head kinematics. The pectoralis major and latissimus dorsi muscles played an

  9. Posterior root tear of the medial and lateral meniscus.

    PubMed

    Petersen, Wolf; Forkel, Philipp; Feucht, Matthias J; Zantop, Thore; Imhoff, Andreas B; Brucker, Peter U

    2014-02-01

    An avulsion of the tibial insertion of the meniscus or a radial tear close to the meniscal insertion is defined as a root tear. In clinical practice, the incidence of these lesions is often underestimated. However, several biomechanical studies have shown that the effect of a root tear is comparable to a total meniscectomy. Clinical studies documented progredient arthritic changes following root tears, thereby supporting basic science studies. The clinical diagnosis is limited by unspecific symptoms. In addition to the diagnostic arthroscopy, MRI is considered to be the gold standard of diagnosis of a meniscal root tear. Three different direct MRI signs for the diagnosis of a meniscus root tear have been described: Radial linear defect in the axial plane, vertical linear defect (truncation sign) in the coronal plane, and the so-called ghost meniscus sign in the sagittal plane. Meniscal extrusion is also considered to be an indirect sign of a root tear, but is less common in lateral root tears. During arthroscopy, the function of the meniscus root must be assessed by probing. However, visualization of the meniscal insertions is challenging. Refixation of the meniscal root can be performed using a transtibial pull-out suture, suture anchors, or side-to-side repair. Several short-term studies reported good clinical results after medial or lateral root repair. Nevertheless, MRI and second-look arthroscopy revealed high rates of incomplete or absent healing, especially for medial root tears. To date, most studies are case series with short-term follow-up and level IV evidence. Outerbridge grade 3 or 4 chondral lesions and varus malalignment of >5° were found to predict an inferior clinical outcome after medial meniscus root repair. Further research is needed to evaluate long-term results and to define evident criteria for meniscal root repair.

  10. Rotator cuff tears: An evidence based approach

    PubMed Central

    Sambandam, Senthil Nathan; Khanna, Vishesh; Gul, Arif; Mounasamy, Varatharaj

    2015-01-01

    Lesions of the rotator cuff (RC) are a common occurrence affecting millions of people across all parts of the globe. RC tears are also rampantly prevalent with an age-dependent increase in numbers. Other associated factors include a history of trauma, limb dominance, contralateral shoulder, smoking-status, hypercholesterolemia, posture and occupational dispositions. The challenge lies in early diagnosis since a high proportion of patients are asymptomatic. Pain and decreasing shoulder power and function should alert the heedful practitioner in recognizing promptly the onset or aggravation of existing RC tears. Partial-thickness tears (PTT) can be bursal-sided or articular-sided tears. Over the course of time, PTT enlarge and propagate into full-thickness tears (FTT) and develop distinct chronic pathological changes due to muscle retraction, fatty infiltration and muscle atrophy. These lead to a reduction in tendon elasticity and viability. Eventually, the glenohumeral joint experiences a series of degenerative alterations - cuff tear arthropathy. To avert this, a vigilant clinician must utilize and corroborate clinical skill and radiological findings to identify tear progression. Modern radio-diagnostic means of ultrasonography and magnetic resonance imaging provide excellent visualization of structural details and are crucial in determining further course of action for these patients. Physical therapy along with activity modifications, anti-inflammatory and analgesic medications form the pillars of nonoperative treatment. Elderly patients with minimal functional demands can be managed conservatively and reassessed at frequent intervals. Regular monitoring helps in isolating patients who require surgical interventions. Early surgery should be considered in younger, active and symptomatic, healthy patients. In addition to being cost-effective, this helps in providing a functional shoulder with a stable cuff. An easily reproducible technique of maximal strength and

  11. Measurement of Tear Production in English Angora and Dutch Rabbits

    PubMed Central

    Rajaei, Seyed Mehdi; Rafiee, Siamak Mashhady; Ghaffari, Masoud Selk; Masouleh, Mohammad N; Jamshidian, Mahmoud

    2016-01-01

    The purpose of this study was to establish normal values for tear production tests in different breeds of domestic rabbits. Healthy adult rabbits (n = 60; 120 eyes) of 2 different breeds (English angora and Dutch; n = 15 of each sex and breed) were used in this study. Tear production was measured by using the 1-min Schirmer tear test (STT), phenol red thread test (PRTT), and endodontic absorbent paper point tear test (EAPTT). In addition, horizontal palpebral fissure length was evaluated as a measure of ocular adnexal dimensions. Tear production (mean ± 1 SD) in English angora rabbits was 5.4 ± 1.6 mm/min according to the STT, 25.0 ± 2.7 mm in 15 s for the PRTT, and 18.8 ± 2.1 mm/min by the EAPTT; in Dutch rabbits, these values were 4.6 ± 1.2 mm/min, 23.6 ± 2.3 mm in 15 s, and 16.9 ± 1.7 mm/min, respectively. Only the EAPTT revealed a significant difference in tear production between English Angora and Dutch rabbits. These results provide reference values for tear production in English Angora and Dutch rabbits according to 3 different quantitative tear film assessment methods. PMID:27025815

  12. Tear Film Dynamics: the roles of complex structure and rheology

    NASA Astrophysics Data System (ADS)

    Dey, Mohar; Feng, James; Vivek, Atul S.; Dixit, Harish N.; Richhariya, Ashutosh

    2016-11-01

    Ocular surface infections such as microbial and fungal keratitis are among leading causes of blindness in the world. A thorough understanding of the pre-corneal tear film dynamics is essential to comprehend the role of various tear layer components in the escalation of such ocular infections. The pre-corneal tear film comprises of three layers of complex fluids, viz. the innermost mucin layer, a hydrophilic protective cover over the sensitive corneal epithelium, the intermediate aqueous layer that forms the bulk of the tear film and is often embedded with large number of bio-polymers either in the form of soluble mucins or pathogens, and finally the outermost lipid layer that stabilizes the film by decreasing the air/tear film interfacial tension. We have developed a comprehensive mathematical model to describe such a film by incorporating the effects of the non-uniform mucin distribution along with the complex rheology of the aqueous layer with/without pathogens, Marangoni effects from the lipid layer and the slip effects at the base of the tear film. A detailed linear stability analysis and a fully non-linear solution determine the break up time (BUT) of such a tear film. We also probe the role of the various components of the pre-corneal tear film in the dynamics of rupture.

  13. Advanced Rotator Cuff Tear Score (ARoCuS): a multi-scaled tool for the classification and description of rotator cuff tears.

    PubMed

    Walter, S G; Stadler, T; Thomas, T S; Thomas, W

    2018-03-02

    To introduce a (semi-)quantitative surgical score for the classification of rotator cuff tears. A total of 146 consecutive patients underwent rotator cuff repair and were assessed using the previously defined Advanced Rotator Cuff Tear Score (ARoCuS) criteria: muscle tendon, size, tissue quality, pattern as well as mobilization of the tear. The data set was split into a training (125 patients) and a testing set (21 patients). The training data set fitted a nonlinear predictive model of the tear score based on the ARoCuS criteria, while the testing data served as control. Based on the scoring results, rotator cuff tears were assigned to one of four categories (ΔV I-IV) and received a stage-adapted treatment. For statistical analysis, mean values ± standard deviation, interclass correlation coefficients (ICC) and kappa values were calculated. Overall, 32 patients were classified as ΔV I, 68 as ΔV II and 37 as ΔV III. Nine patients showed ΔV IV tears. Patients of all ΔV groups improved significantly their Constant scores (p < 0.001) and profited from significant pain reduction after surgery (p < 0.001). To date, ten patients have undergone revision surgery with five of them primarily classified as ΔV IV. Kappa values for the interobserver reliability ranged between 0.69 and 0.95. ICC scores for the ΔV category were 0.95 for interobserver reliability. The ARoCuS facilitates intra-operative decision-making and enables surgeons and researches to document rotator cuff tears in a standardized and reproducible manner.

  14. Interferometric measurements of the tear film irregularities on the human cornea

    NASA Astrophysics Data System (ADS)

    Szczesna, Dorota H.; Jaronski, Jaroslaw; Kasprzak, Henryk T.; Stenevi, Ulf

    2005-09-01

    The pre-ocular tear film is the most anterior refractive surface of the eye. Its stability plays an important role in the condition of vision from the optical and physiological point of view. If the eye is opened for a significantly long time or suffers from an anormalities in tear production, there appear isolated dry islands - break-ups - with a random distribution in the continuous lacrimal film. We applied an interferometric method - Lateral Shearing Technique for investigating the tear film stability and the smoothness of the tear film surface. This method is non-invasive and it is characterised by the high accuracy and sensitivity. Interferometry allows dynamic measurements of the tear film stability in real time by observation of interference fringes. The evaporation of tears and appearance of the breakups causes changes in the fringe geometry. Fast Fourier Transform has been used for quantitative assessment of the fringe smoothness and as a consequence of the tear film surface geometry. This paper presents the method used for quantitative evaluation of the tear film distribution on the cornea. Examples of interferograms recorded on eyes of patients with healthy eyes, suffering from dry eye syndrome and wearing contact lenses are also given. With our technique we were able to observe distinct differences in stability of the tear film between healthy and dry eyes, and the tear film on contact lenses.

  15. Diagnostic accuracy of 3T conventional shoulder MRI in the detection of the long head of the biceps tendon tears associated with rotator cuff tendon tears.

    PubMed

    Lee, Ro Woon; Choi, Soo-Jung; Lee, Man Ho; Ahn, Jae Hong; Shin, Dong Rock; Kang, Chae Hoon; Lee, Ki Won

    2016-12-01

    To evaluate the diagnostic performance (DP) of 3T (3 Tesla field strength) conventional shoulder magnetic resonance imaging (MRI) in detecting the long head of the biceps tendon (LHBT) tears in association with rotator cuff tendon tears. This study included 80 consecutive patients who underwent arthroscopic surgery for rotator cuff tendon tears. Two radiologists independently evaluated the preoperative 3T shoulder MRI for the presence of LHBT tears. The DP of MRI was evaluated using the results of arthroscopy as the reference standard. We also evaluated the DP of several MR signs of LHBT in detection of partial LHBT tears. Arthroscopic examination revealed 35 partial and 5 complete tears. According to the results of evaluation by reviewers 1 and 2, shoulder MRI exhibited sensitivities of 77.14 and 80 % and specificities of 71.11 and 73.33 % in detection of partial LHBT tears and sensitivities of 80 and 100 % and a specificity of 100% (both) in detection of complete LHBT tears. In detecting partial LHBT tears, increased T2 signal intensity of the LHBT exhibited high sensitivities (reviewers 1 and 2; 82.85 and 80 %, respectively) and the presence of intratendinous defects or C-signs exhibited the highest specificities (reviewers 1 and 2; 95.55 and 93.33 %, respectively), followed by abnormalities in shape and outer margins of the LHBT (reviewers 1 and 2; 91.11 and 82 %; 91.11 and 86.66 %, respectively). Non-contrast-enhanced 3T shoulder MRI is potentially highly accurate in detection of complete LHBT tears, but moderately accurate in detection of partial LHBT tears.

  16. Influence of toroidal rotation on tearing modes

    NASA Astrophysics Data System (ADS)

    Cai, Huishan; Cao, Jintao; Li, Ding

    2017-10-01

    Tearing modes stability analysis including toroidal rotation is studied. It is found that rotation affects the stability of tearing modes mainly through the interaction with resistive inner region of tearing mode. The coupling of magnetic curvature with centrifugal force and Coriolis force provides a perturbed perpendicular current, and a return parallel current is induced to affect the stability of tearing modes. Toroidal rotation plays a stable role, which depends on the magnitude of Mach number and adiabatic index Γ, and is independent on the direction of toroidal rotation. For Γ >1, the scaling of growth rate is changed for typical Mach number in present tokamaks. For Γ = 1 , the scaling keeps unchanged, and the effect of toroidal rotation is much less significant, compared with that for Γ >1. National Magnetic Confinement Fusion Science Program and National Science Foundation of China under Grants No. 2014GB106004, No. 2013GB111000, No. 11375189, No. 11075161 and No. 11275260, and Youth Innovation Promotion Association CAS.

  17. Rotator cuff tears in children and adolescents: experience at a large pediatric hospital.

    PubMed

    Zbojniewicz, Andrew M; Maeder, Matthew E; Emery, Kathleen H; Salisbury, Shelia R

    2014-06-01

    Prior literature, limited to small case series and case reports, suggests that rotator cuff tears are rare in adolescents. However, we have identified rotator cuff tears in numerous children and adolescents who have undergone shoulder MRI evaluation. The purpose of this study is to describe the prevalence and characteristics of rotator cuff tears in children and adolescents referred for MRI evaluation of the shoulder at a large pediatric hospital and to correlate the presence of rotator cuff tears with concurrent labral pathology, skeletal maturity and patient activity and outcomes. We reviewed reports from 455 consecutive non-contrast MRI and magnetic resonance arthrogram examinations of the shoulder performed during a 2-year period, and following exclusions we yielded 205 examinations in 201 patients (ages 8-18 years; 75 girls, 126 boys). Rotator cuff tears were classified by tendon involved, tear thickness (partial or full), surface and location of tear (when partial) and presence of delamination. We recorded concurrent labral pathology when present. Physeal patency of the proximal humerus was considered open, closing or closed. Statistical analysis was performed to evaluate for a relationship between rotator cuff tears and degree of physeal patency. We obtained patient activity at the time of injury, surgical reports and outcomes from clinical records when available. Twenty-five (12.2%) rotator cuff tears were identified in 17 boys and 7 girls (ages 10-18 years; one patient had bilateral tears). The supraspinatus tendon was most frequently involved (56%). There were 2 full-thickness and 23 partial-thickness tears with articular-side partial-thickness tears most frequent (78%). Insertional partial-thickness tears were more common (78%) than critical zone tears (22%) and 10 (43%) partial-thickness tears were delamination tears. Nine (36%) patients with rotator cuff tears had concurrent labral pathology. There was no statistically significant relationship between

  18. Tearing relaxation and the globalization of transport in field-reversed configurations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steinhauer, Loren; Barnes, D. C.

    2009-09-15

    Tearing instability of field-reversed configurations (FRC) is investigated using the method of neighboring equilibria. It is shown that the conducting wall position in experiment lies very close to the location needed for tearing stability. This strongly suggests that vigorous but benign tearing modes, acting globally, are the engine of continual self-organization in FRCs, i.e., tearing relaxation. It also explains the ''profile consistency'' and anomalous loss rate of magnetic flux. In effect, tearing globalizes the effect of edge-driven transport.

  19. Predicting Rotator Cuff Tears Using Data Mining and Bayesian Likelihood Ratios

    PubMed Central

    Lu, Hsueh-Yi; Huang, Chen-Yuan; Su, Chwen-Tzeng; Lin, Chen-Chiang

    2014-01-01

    Objectives Rotator cuff tear is a common cause of shoulder diseases. Correct diagnosis of rotator cuff tears can save patients from further invasive, costly and painful tests. This study used predictive data mining and Bayesian theory to improve the accuracy of diagnosing rotator cuff tears by clinical examination alone. Methods In this retrospective study, 169 patients who had a preliminary diagnosis of rotator cuff tear on the basis of clinical evaluation followed by confirmatory MRI between 2007 and 2011 were identified. MRI was used as a reference standard to classify rotator cuff tears. The predictor variable was the clinical assessment results, which consisted of 16 attributes. This study employed 2 data mining methods (ANN and the decision tree) and a statistical method (logistic regression) to classify the rotator cuff diagnosis into “tear” and “no tear” groups. Likelihood ratio and Bayesian theory were applied to estimate the probability of rotator cuff tears based on the results of the prediction models. Results Our proposed data mining procedures outperformed the classic statistical method. The correction rate, sensitivity, specificity and area under the ROC curve of predicting a rotator cuff tear were statistical better in the ANN and decision tree models compared to logistic regression. Based on likelihood ratios derived from our prediction models, Fagan's nomogram could be constructed to assess the probability of a patient who has a rotator cuff tear using a pretest probability and a prediction result (tear or no tear). Conclusions Our predictive data mining models, combined with likelihood ratios and Bayesian theory, appear to be good tools to classify rotator cuff tears as well as determine the probability of the presence of the disease to enhance diagnostic decision making for rotator cuff tears. PMID:24733553

  20. Investigation of Tear Biomarkers as an Indicator of Human Health

    NASA Technical Reports Server (NTRS)

    Morton, Stephen; Tucker, Bethany; Crucian, Brian; Steinberg, Susan; Hagan, Suzanne

    2017-01-01

    Scientific literature suggests that tear biomarkers can be used as a guide towards clinical diagnosis of human health (Hagan et al., 2016). This study will investigate whether tear biomarkers represents a research and clinical opportunity to assess human health prior to, during, and after exposure to the spaceflight environment. The focus of this study is to compare biomarkers previously identified as potentially relevant to both ocular and brain health against unique physiological outcomes of exposure to the space flight environment. Study subjects suffering from terrestrial conditions thought to be similar to Spaceflight Associated Neuro-ocular Syndrome (SANS: formerly VIIP), e.g. patients with idiopathic intracranial hypertension (IIH) and optic neuritis may be relevant to conditions associated with spaceflight. This study will review methodologies, tear biomarkers related to state of ocular and brain health, the strengths and weakness of using tear fluid biomarkers versus other body fluid samples, and will survey current tear fluid biomarker knowledge in research and clinical practice. A strength of using tear biomarkers is that sampling is non-invasive and used as a guide in understanding pathologies, including ocular and systemic inflammatory conditions (Cocho et al., 2016)., Salvisberg et al., 2014). Moreover, tear biomarkers may reflect diseases affecting the central nervous system (CNS) (Salvisberg et al., 2014). For example, in multiple sclerosis (MS), the concordance rate between tear biomarkers versus cerebrospinal fluid (CSF) is approximately 83%, indicating that, in the majority of cases, tears are at least as effective as CSF in potentially identifying novel MS biomarkers (Devos et al., 2001).

  1. The Coracohumeral Distance in Shoulders With Traumatic and Degenerative Subscapularis Tendon Tears.

    PubMed

    Balke, Maurice; Banerjee, Marc; Greshake, Oliver; Hoeher, Juergen; Bouillon, Bertil; Liem, Dennis

    2016-01-01

    A reduced coracohumeral distance (CHD) is thought to be responsible for subcoracoid impingement. This only accounts for degenerative tendon tears. In traumatic tears, the subcoracoid space should be normal. The CHD in patients with traumatic subscapularis tendon tears is larger than that in patients with degenerative tears and does not differ from patients with an intact subscapularis tendon. Cohort study; Level of evidence, 3. A total of 83 patients with arthroscopically certified subscapularis tendon tears were included in the study. Forty-four patients had degenerative causes (group 1), and 39 had traumatic causes (group 2). The control group consisted of 20 patients with traumatic supraspinatus tendon tears and arthroscopically proven, intact subscapularis tendons (group 3). On preoperative axial magnetic resonance imaging, the distance between the CHD was measured, and the values of the 3 groups were compared using the t test. The mean (±SD) CHD in patients with degenerative subscapularis tendon tears was 8.6 ± 2.0 mm (range, 4.0-13.2 mm) and was significantly (P = .0003) smaller than that in patients with traumatic tears (10.2 ± 2.0 mm; range, 6.6-16.2 mm) or controls (10.4 ± 1.8 mm; range, 6.8-14.0 mm). The CHD of controls and patients with traumatic tears did not differ significantly (P = .7875). A CHD of less than 6 mm only occurred in patients with degenerative subscapularis tendon tears. The hypothesis that the CHD in patients with degenerative subscapularis tendon tears is significantly smaller than that in patients with traumatic tears or intact subscapularis tendons was confirmed. The CHD in patients with traumatic tears does not differ from that in controls. A CHD of less than 6 mm only occurs in patients with degenerative subscapularis tendon tears. © 2015 The Author(s).

  2. Interactions of toroidally coupled tearing modes in the KSTAR tokamak

    NASA Astrophysics Data System (ADS)

    Kim, Gnan; Yun, Gunsu S.; Woo, Minho; Park, Hyeon K.; KSTAR Team2, the

    2018-03-01

    The evolutions of toroidally coupled radially-distant and radially-adjacent tearing modes are visualized in 2D in detail on the Korea superconducting tokamak for advanced research. The coupled tearing modes are in-phase on the out-board mid-plane and become destabilized or compete with each other depending on their spatial separation. When two coupled tearing modes are far apart, both are increasingly destabilized. On the other hand, when they become close to each other, one becomes stabilized while the other becomes destabilized. In such cases, an additional tearing mode is often formed on outer rational flux surface and the three tearing modes compete. The competitions suggest that spatial overlap (merging) of coupled magnetic islands is difficult.

  3. A review of patient and skin characteristics associated with skin tears.

    PubMed

    Rayner, R; Carville, K; Leslie, G; Roberts, P

    2015-09-01

    Skin tears are the most common wound among the elderly and have the potential to cause infection, form chronic wounds, reduce quality of life and increase health-care costs. Our aim was to identify studies that reviewed patient and skin characteristics associated with skin tears. A review of skin tear studies reported in the English literature between 1980 and 2013 was undertaken using the following electronic databases: PubMed, Medline, CINAHL, Embase, Scopus, Evidence Based and Medicine Reviews (EBM). Search terms included aged, skin, tears or lacerations, skin tearing, geri tear, epidermal tear and prevalence. There were 343 articles found with using the search terms. After abstract review nine were found to be relevant to the search. The principle findings from these eight published articles and one unpublished study revealed that the most common patient characteristics were a history of skin tears, impaired mobility and impaired cognition. Skin characteristics associated with skin tears included senile purpura, ecchymosis and oedema. This review provides an overview of identified patient and skin characteristics that predispose the elderly to skin tears and exposes the lack of research within this domain. R. Rayner is a recipient of a 2013 Australian Postgraduate Award, Curtin University Postgraduate Scholarship and a Wound Management Cooperative Research Centre (CRC) PhD stipend. The School of Nursing, Midwifery and Paramedicine, Curtin University and the Silver Chain Group, Western Australia are participants in the Wound Management Innovation CRC. No conflict of interest exists among the authors.

  4. Geotribology - Friction, wear, and lubrication of faults

    NASA Astrophysics Data System (ADS)

    Boneh, Yuval; Reches, Ze'ev

    2018-05-01

    We introduce here the concept of Geotribology as an approach to study friction, wear, and lubrication of geological systems. Methods of geotribology are applied here to characterize the friction and wear associated with slip along experimental faults composed of brittle rocks. The wear in these faults is dominated by brittle fracturing, plucking, scratching and fragmentation at asperities of all scales, including 'effective asperities' that develop and evolve during the slip. We derived a theoretical model for the rate of wear based on the observation that the dynamic strength of brittle materials is proportional to the product of load stress and loading period. In a slipping fault, the loading period of an asperity is inversely proportional to the slip velocity, and our derivations indicate that the wear-rate is proportional to the ratio of [shear-stress/slip-velocity]. By incorporating the rock hardness data into the model, we demonstrate that a single, universal function fits wear data of hundreds of experiments with granitic, carbonate and sandstone faults. In the next step, we demonstrate that the dynamic frictional strength of experimental faults is well explained in terms of the tribological parameter PV factor (= normal-stress · slip-velocity). This factor successfully delineates weakening and strengthening regimes of carbonate and granitic faults. Finally, our analysis revealed a puzzling observation that wear-rate and frictional strength have strikingly different dependencies on the loading conditions of normal-stress and slip-velocity; we discuss sources for this difference. We found that utilization of tribological tools in fault slip analyses leads to effective and insightful results.

  5. Acute Medial Plantar Fascia Tear.

    PubMed

    Pascoe, Stephanie C; Mazzola, Timothy J

    2016-06-01

    A 32-year-old man who participated in competitive soccer came to physical therapy via direct access for a chief complaint of plantar foot pain. The clinical examination findings and mechanism of injury raised a concern for a plantar fascia tear, so the patient was referred to the physician and magnetic resonance imaging was obtained. The magnetic resonance image confirmed a high-grade, partial-thickness, proximal plantar fascia tear with localized edema at the location of the medial band. J Orthop Sports Phys Ther 2016;46(6):495. doi:10.2519/jospt.2016.0409.

  6. Goldmann tonometry tear film error and partial correction with a shaped applanation surface.

    PubMed

    McCafferty, Sean J; Enikov, Eniko T; Schwiegerling, Jim; Ashley, Sean M

    2018-01-01

    The aim of the study was to quantify the isolated tear film adhesion error in a Goldmann applanation tonometer (GAT) prism and in a correcting applanation tonometry surface (CATS) prism. The separation force of a tonometer prism adhered by a tear film to a simulated cornea was measured to quantify an isolated tear film adhesion force. Acrylic hemispheres (7.8 mm radius) used as corneas were lathed over the apical 3.06 mm diameter to simulate full applanation contact with the prism surface for both GAT and CATS prisms. Tear film separation measurements were completed with both an artificial tear and fluorescein solutions as a fluid bridge. The applanation mire thicknesses were measured and correlated with the tear film separation measurements. Human cadaver eyes were used to validate simulated cornea tear film separation measurement differences between the GAT and CATS prisms. The CATS prism tear film adhesion error (2.74±0.21 mmHg) was significantly less than the GAT prism (4.57±0.18 mmHg, p <0.001). Tear film adhesion error was independent of applanation mire thickness ( R 2 =0.09, p =0.04). Fluorescein produces more tear film error than artificial tears (+0.51±0.04 mmHg; p <0.001). Cadaver eye validation indicated the CATS prism's tear film adhesion error (1.40±0.51 mmHg) was significantly less than that of the GAT prism (3.30±0.38 mmHg; p =0.002). Measured GAT tear film adhesion error is more than previously predicted. A CATS prism significantly reduced tear film adhesion error bŷ41%. Fluorescein solution increases the tear film adhesion compared to artificial tears, while mire thickness has a negligible effect.

  7. A new, specular reflection-based, precorneal tear film stability measurement technique in a rabbit model: viscoelastic increases tear film stability.

    PubMed

    Nankivil, Derek; Gonzalez, Alex; Arrieta, Esdras; Rowaan, Cornelis; Aguilar, Mariela C; Sotolongo, Krystal; Cabot, Florence A; Yoo, Sonia H; Parel, Jean-Marie A

    2014-06-19

    To develop a safe, noninvasive, noncontact, continuous in vivo method to measure the dehydration rate of the precorneal tear film and to compare the effectiveness of a viscoelastic agent in maintaining the precorneal tear film to that of a balanced salt solution. Software was designed to analyze the corneal reflection produced by the operating microscope's coaxial illumination. The software characterized the shape of the reflection, which became distorted as the precorneal tear film evaporated; characterization was accomplished by fitting an ellipse to the reflection and measuring its projected surface area. Balanced salt solution Plus (BSS+) and a 2% hydroxypropylmethylcellulose viscoelastic were used as the test agents. The tear film evaporation rate was characterized and compared over a period of 20 minutes in 20 eyes from 10 New Zealand white rabbits. The ellipse axes ratio and surface area were found to decrease initially after each application of either viscoelastic or BSS+ and then to increase linearly as the tear film began to evaporate (P < 0.001) for eyes treated with BSS+ only. Eyes treated with BSS+ required 7.5 ± 2.7 applications to maintain sufficient corneal hydration during the 20-minute test period, whereas eyes treated with viscoelastic required 1.4 ± 0.5 applications. The rates of evaporation differed significantly (P < 0.043) between viscoelastic and BSS+. The shape and surface area of the corneal reflection are strongly correlated with the state of the tear film. Rabbits' corneas treated with viscoelastic remained hydrated significantly longer than corneas treated with BSS+. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  8. [Functional tear production indices in thyroid eye disease].

    PubMed

    Safonova, T N; Likhvantseva, V G; Gontiurova, O A; Rudenko, E I; Vygodin, V A

    2013-01-01

    Analysis of functional tear production indices in patients with Grave's disease and thyroid eye disease confirmed lacrimal gland involvement in inflammatory autoimmune process. Close direct correlation was found between tear production and main disease characteristics - severity and activity.

  9. The potential of optical coherence tomography in meniscal tear characterization

    NASA Astrophysics Data System (ADS)

    Ling, Hang-yin; Guo, Shuguang; Thieman, Kelley M.; Wise, Brent T.; Pozzi, Antonio; Xie, Huikai; Horodyski, MaryBeth

    2009-02-01

    Meniscal tear is one of the most common knee injuries leading to pain and discomfort. Partial and total meniscectomies have been widely used to treat the avascular meniscal injuries in which tears do not heal spontaneously. However, the meniscectomies would cause an alteration of the tibiofemoral contact mechanics resulting in progressive osteoarthritis (OA). To mitigate the progression of OA, maximal preservation of meniscal tissue is recommended. The clinical challenge is deciding which meniscal tears are amenable to repair and which part of damaged tissues should be removed. Current diagnosis techniques such as arthroscopy and magnetic resonance imaging can provide macrostructural information of menisci, but the microstructural changes that occur prior to the observable meniscal tears cannot be identified by these techniques. Serving as a nondestructive optical biopsy, optical coherence tomography (OCT), a newly developed imaging modality, can provide high resolution, cross-sectional images of tissues and has been shown its capabilty in arthroscopic evaulation of articular cartilage. Our research was to demonstrate the potential of using OCT for nondestructive characterization of the histopathology of different types of meniscal tears from clinical cases in dogs, providing a fundamental understanding of the failure mechanism of meniscal tears. First, cross-sectional images of torn canine menisci obtained from the OCT and scanning electronic microscopy (SEM) were be compared. By studying the organization of collegan fibrils in torn menisci from the SEM images, the feasibility of using OCT to characterize the organization of collegan fibrils was elucidated. Moreover, the crack size of meniscal tears was quantatitively measured from the OCT images. Changes in the crack size of the tear may be useful for understanding the failure mechanism of meniscal tears.

  10. Oxidative Stress Measures of Lipid and DNA Damage in Human Tears.

    PubMed

    Haworth, Kristina M; Chandler, Heather L

    2017-05-01

    We evaluate feasibility and repeatability of measures for lipid peroxidation and DNA oxidation in human tears, as well as relationships between outcome variables, and compared our findings to previously reported methods of evaluation for ocular sun exposure. A total of 50 volunteers were seen for 2 visits 14 ± 2 days apart. Tear samples were collected from the inferior tear meniscus using a glass microcapillary tube. Oxidative stress biomarkers were quantified using enzyme-linked immunosorbent assay (ELISA): lipid peroxidation by measurement of hexanoyl-lysine (HEL) expression; DNA oxidation by measurement of 8-oxo-2'-deoxyguinosone (8OHdG) expression. Descriptive statistics were generated. Repeatability estimates were made using Bland-Altman plots with mean differences and 95% limits of agreement were calculated. Linear regression was conducted to evaluate relationships between measures. Mean (±SD) values for tear HEL and 8OHdG expression were 17368.02 (±9878.42) nmol/L and 66.13 (±19.99) ng/mL, respectively. Repeatability was found to be acceptable for both HEL and 8OHdG expression. Univariate linear regression supported tear 8OHdG expression and spring season of collection to be predictors of higher tear HEL expression; tear HEL expression was confirmed as a predictor of higher tear 8OHdG expression. We demonstrate feasibility and repeatability of estimating previously unreported tear 8OHdG expression. Seasonal temperature variation and other factors may influence tear lipid peroxidation. Support is demonstrated to suggest lipid damage and DNA damage occur concurrently on the human ocular surface.

  11. A comparison of MRI findings in patients with acute and chronic ACL tears.

    PubMed

    Dimond, P M; Fadale, P D; Hulstyn, M J; Tung, G A; Greisberg, J

    1998-01-01

    This retrospective study compared the magnetic resonance imaging (MRI) findings in 87 patients with acute and chronic anterior cruciate ligament (ACL) tears. Sixty patients had acute tears and 27 had chronic tears. The appearance of the torn ligament was examined on MRI, and associated meniscal and osteochondral injuries were described. All findings were verified at arthroscopy. Acute ACL tears (MRI examination was performed within 6 weeks of injury) were typified by the presence of diffuse (58%) or focal (42%) increased signal within the ligament, whereas chronic ACL tears (MRI examination was performed more than 6 months after injury) usually appeared as either a fragmented ligament (44%) or an intact band of low signal with abnormal orientation (30%). Patients with chronic ACL tears had a higher prevalence of medial meniscal tears (78% versus 40%), articular chondromalacia, and an increased posterior cruciate bow ratio (0.47 versus 0.37) in association with chronic ACL tears. A bone bruise was seen in 68% of acute ACL tears but in no case of chronic ACL tear. On MRI, there are salient differences between acute and chronic ACL tears. Chronic ACL tears are associated with a greater prevalence of meniscal and osteochondral injuries. These findings may have implications for future treatment recommendations.

  12. Learning curve of office-based ultrasonography for rotator cuff tendons tears.

    PubMed

    Ok, Ji-Hoon; Kim, Yang-Soo; Kim, Jung-Man; Yoo, Tae-Wook

    2013-07-01

    To compare the accuracy of ultrasonography and MR arthrography (MRA) imaging in detecting of rotator cuff tears with arthroscopic finding used as the reference standard. The ultrasonography and MRA findings of 51 shoulders that underwent the arthroscopic surgery were prospectively analysed. Two orthopaedic doctors independently performed ultrasonography and interpreted the findings at the office. The tear size measured at ultrasonography and MRA was compared with the size measured at surgery using Pearson correlation coefficients (r). The sensitivity, specificity, accuracy, positive predictive value, negative predictive value and false-positive rate were calculated for a diagnosis of partial-and full-thickness rotator cuff tears. The kappa coefficient was calculated to verify the inter-observer agreement. The sensitivity of ultrasonography and MRA for detecting partial-thickness tears was 45.5 and 72.7 %, and that for full-thickness tears was 80.0 and 100 %, respectively. The accuracy of ultrasonograpy and MRA for detecting partial-thickness tears was 45.1 and 88.2 %, and that for full-thickness tears was 82.4 and 98 %, respectively. Tear size measured based on ultrasonography examination showed a poor correlation with the size measured at arthroscopic surgery (r = 0.21; p < 0.05). However, tear size estimated by MRA showed a strong correlation (r = 0.75; p < 0.05). The kappa coefficient was 0.47 between the two independent examiners. The accuracy of office-based ultrasonography for beginner orthopaedic surgeons to detect full-thickness rotator cuff tears was comparable to that of MRA but was less accurate for detecting partial-thickness tears and torn size measurement. Inter-observer agreement on the interpretation was fair. These results highlight the importance of the correct technique and experience in operation of ultrasonography in shoulder joint. Diagnostic study, Level II.

  13. Fluorophotometric measurement of the buffering action of human tears in vivo.

    PubMed

    Yamada, M; Kawai, M; Mochizuki, H; Hata, Y; Mashima, Y

    1998-10-01

    The buffering action of human tears is thought to be important to keep its pH constant. We measured the change in pH in the precorneal tear film in vivo when the acidic solution is challenged, using a fluorophotometric technique. Twelve eyes from 6 healthy subjects were entered in this study. Each subject was pretreated with either one drop of 0.4% oxybuprocaine for once (light anesthesia), three times (deep anesthesia), or none (controls). The measurement was initiated by instilling 20 microl of 0.067 M phosphate buffer at pH 5.5 containing 2 mM bis-carboxyethyl-carboxyfluorescein free acid, a pH sensitive dye, into the subject's eye. The pH was determined by the ratio of fluorescent intensities at two excitation wavelengths (490 and 430 nm). pH recovery time (PHRT) as defined by the time required for pH to reach 95% of pH at equilibrium was used for the marker of tear buffering action. Tear turnover rate was also determined using the fluorescent decay curve at 430 nm, which was independent of pH, but dependent on dye concentration. Immediately after the instillation, the pH value in the tear film was around 6.0-6.5 in all cases. The tear film rapidly became more alkaline, reaching its normal value in 2.3 +/- 0.5 min in untreated eyes. The pretreatment with 0.4% oxybuprocaine retarded the neutralization process. A single regression analysis revealed that the PHRT had a significant negative correlation with the tear turnover rate (r = -0.78). Our results suggest that the neutralization process of tears largely depends on the tear turnover rate. The buffering action of tears in vivo consists of the tear turnover as well as its chemical buffering capacity.

  14. Superior Labral Anterior-Posterior (SLAP) Tears in the Military.

    PubMed

    Rossy, William; Sanchez, George; Sanchez, Anthony; Provencher, Matthew T

    Given the notable physical demands placed on active members of the military, comprehension of recent trends in management and outcomes of superior labral anterior-posterior (SLAP) tears in this patient population is critical for successful treatment. Electronic databases, including PubMed, MEDLINE, and Embase, were reviewed for the years 1985 through 2016. Database review. Level 5. Active members of the military are at increased risk of sustaining shoulder injuries, particularly SLAP tears. Recent trends in management of SLAP lesions have shifted toward operative intervention. In the correct patient population, repairs of superior labrum tears demonstrate improved function and pain. Surgical repair of SLAP tears, especially in young and active military personnel, is supported. Military personnel are at greater risk of suffering a SLAP tear in comparison with their civilian counterparts. Surgical repair of these lesions is advocated in this subpopulation when the patient is younger than approximately 36 years of age, and if older, biceps tenodesis is likely superior.

  15. Simultaneous measurement of tear film dynamics using wavefront sensor and optical coherence tomography.

    PubMed

    Koh, Shizuka; Tung, Cynthia; Aquavella, James; Yadav, Rahul; Zavislan, James; Yoon, Geunyoung

    2010-07-01

    PURPOSE. To investigate tear film dynamics using simultaneous measurements of ocular aberrations and lower tear meniscus. METHODS. Simultaneous measurements of wavefront aberration and lower tear meniscus were performed for 11 normal eyes and 7 eyes with short tear film break-up time (SBUT) dry eye, with a tear film break-up time shorter than 5 seconds, using a wavefront sensor and an anterior segment optical coherence tomography (OCT). During the measurement, the subjects were instructed to blink every 6 seconds for a total of 30 seconds. From the measured aberration, root mean square (RMS) wavefront error and volume modulation transfer function (vMTF) induced by changes in tear film dynamics were calculated for a 5-mm pupil. Lower tear meniscus height (TMH) and area (TMA) were estimated from the cross-sectional OCT images of lower tear meniscus. RESULTS. There was a positive correlation between RMS and tear meniscus dimensions and a negative correlation between vMTF and tear meniscus in both groups. There were moderate negative correlations between the postblink initial RMS change and baseline TMH (R = -0.61) and TMA (R = -0.54) in SBUT dry eyes that were stronger than in normal eyes (R = -0.37, R = -0.38). CONCLUSIONS. Tear meniscus dimensions increase with RMS over time, and tear quantity before blink has a significant role in maintaining initial optical integrity, especially in SBUT dry eye. Simultaneous measurement of optical quality and tear meniscus has the potential to improve understanding of tear stability in normal eyes and dry eyes.

  16. Geophysical setting of the Wabash Valley fault system

    USGS Publications Warehouse

    Hildenbrand, T.G.; Ravat, D.

    1997-01-01

    Interpretation of existing regional magnetic and gravity data and new local high-resolution aeromagnetic data provides new insights on the tectonic history and structural development of the Wabash Valley Fault System in Illinois and Indiana. Enhancement of short-wavelength magnetic anomalies reveal numerous NW- to NNE-trending ultramafic dikes and six intrusive complexes (including those at Hicks Dome and Omaha Dome). Inversion models indicate that the interpreted dikes are narrow (???3 m), lie at shallow depths (500 km long and generally >50 km wide) and with deep basins (locally >3 km thick), the ancestral Wabash Valley faults express, in comparison, minor tectonic structures and probably do not represent a failed rift arm. There is a lack of any obvious relation between the Wabash Valley Fault System and the epicenters of historic and prehistoric earthquakes. Five prehistoric earthquakes lie conspicuously near structures associated with the Commerce geophysical lineament, a NE-trending magnetic and gravity lineament lying oblique to the Wabash Valley Fault System and possibly extending over 600 km from NE Arkansas to central Indiana.

  17. Salt movements and faulting of the overburden - can numerical modeling predict the fault patterns above salt structures?

    NASA Astrophysics Data System (ADS)

    Clausen, O. R.; Egholm, D. L.; Wesenberg, R.

    2012-04-01

    Salt deformation has been the topic of numerous studies through the 20th century and up until present because of the close relation between commercial hydrocarbons and salt structure provinces of the world (Hudec & Jackson, 2007). The fault distribution in sediments above salt structures influences among other things the productivity due to the segmentation of the reservoir (Stewart 2006). 3D seismic data above salt structures can map such fault patterns in great detail and studies have shown that a variety of fault patterns exists. Yet, most patterns fall between two end members: concentric and radiating fault patterns. Here we use a modified version of the numerical spring-slider model introduced by Malthe-Sørenssen et al.(1998a) for simulating the emergence of small scale faults and fractures above a rising salt structure. The three-dimensional spring-slider model enables us to control the rheology of the deforming overburden, the mechanical coupling between the overburden and the underlying salt, as well as the kinematics of the moving salt structure. In this presentation, we demonstrate how the horizontal component on the salt motion influences the fracture patterns within the overburden. The modeling shows that purely vertical movement of the salt introduces a mesh of concentric normal faults in the overburden, and that the frequency of radiating faults increases with the amount of lateral movements across the salt-overburden interface. The two end-member fault patterns (concentric vs. radiating) can thus be linked to two different styles of salt movement: i) the vertical rising of a salt indenter and ii) the inflation of a 'salt-balloon' beneath the deformed strata. The results are in accordance with published analogue and theoretical models, as well as natural systems, and the model may - when used appropriately - provide new insight into how the internal dynamics of the salt in a structure controls the generation of fault patterns above the structure. The

  18. Ply-tear webbing energy absorber

    NASA Technical Reports Server (NTRS)

    Stevens, G. W. H.

    1972-01-01

    Ply-tear webbing is essentially two plain webbings that are bound together by a portion of the warps and that can be torn apart and do work by breaking the binders. Nylon webbing were woven to range in tear force from 1 to 10 kilonewtons. This force is substantially independent of speed, which was as high as 100 m/sec in some cases. A specific energy absorption of 90 J/g was achieved in the dry state. However, lower rated webbings that absorb approximately 40 J/g are recommended for use in practice where it is acceptable.

  19. Beyond Brittle Deformation: Insights into Seismogenic Slip Processes from Natural and Experimental Faults

    NASA Astrophysics Data System (ADS)

    Holdsworth, R.; De Paola, N.; Bullock, R. J.; Collettini, C.; Viti, C.; Nielsen, S. B.

    2015-12-01

    Shear displacements in upper crustal faults are typically localized within cm- to m-thick high strain fault cores composed of interlayered tabular domains of cataclasite and gouge. Evidence from exhumed/exposed seismic faults shows that the great majority of co-seismic slip is taken up along narrow (<10 cm) ultracataclasite slip zones, containing thin (<100μm) principal slip zones (PSZ) bounded by sharp, polished and striated principal slip surfaces (PSS). Even in unconsolidated materials deformed near to the surface, seismogenic slip is observed to localize within discrete, narrow PSZs. Theoretical studies suggest that in all but the shallowest settings, the natural PSZs may be sufficiently thin to generate localised frictional heating that potentially promotes thermally-activated dynamic weakening mechanisms. We can recreate these processes in the laboratory using displacement-controlled friction experiments performed in a rotary shear apparatus on fault gouges of known composition deformed at seismic slip rates (v > 1ms-1) and normal stresses of up to 20 MPa. A sequential sampling approach is used in which slip is arrested at different stages of the observed friction evolution (e.g. post-compaction, peak friction, steady state after weakening). This allows the evolution of gouge microstructures and deformation mechanisms in the experimental samples to be: a) related to the evolving temperature regimes in the PSZ and changing mechanical behavior; and b) compared to natural PSZ/PSSs. Using this approach we have investigated the behavior and deformation mechanisms of gouges made of common, rock-forming minerals (calcite, clays, olivine, quartz) both in pure form and, in some cases, as mixed compositions deformed under a range of experimental conditions. We have studied the effects of varying confining pressure, fluid content (room humidity vs water saturated) and composition (de-ionized water vs brine) and slip rate (e.g. seismic vs. sub-seismic). Our findings

  20. A Voyager attitude control perspective on fault tolerant systems

    NASA Technical Reports Server (NTRS)

    Rasmussen, R. D.; Litty, E. C.

    1981-01-01

    In current spacecraft design, a trend can be observed to achieve greater fault tolerance through the application of on-board software dedicated to detecting and isolating failures. Whether fault tolerance through software can meet the desired objectives depends on very careful consideration and control of the system in which the software is imbedded. The considered investigation has the objective to provide some of the insight needed for the required analysis of the system. A description is given of the techniques which have been developed in this connection during the development of the Voyager spacecraft. The Voyager Galileo Attitude and Articulation Control Subsystem (AACS) fault tolerant design is discussed to emphasize basic lessons learned from this experience. The central driver of hardware redundancy implementation on Voyager was known as the 'single point failure criterion'.

  1. Non-invasive pre-lens tear film assessment with high-speed videokeratoscopy.

    PubMed

    Llorens-Quintana, Clara; Mousavi, Maryam; Szczesna-Iskander, Dorota; Iskander, D Robert

    2018-02-01

    To evaluate the effect of two types of daily contact lenses (delefilcon A and omafilcon A) on the tear film and establish whether it is dependent on pre-corneal tear film characteristics using a new method to analyse high-speed videokeratoscopy recordings, as well as to determine the sensitivity of the method in differentiating between contact lens materials on eye. High-speed videokeratoscopy recordings were analysed using a custom made automated algorithm based on a fractal dimension approach that provides a set of parameters directly related to tear film stability. Fifty-four subjects participated in the study. Baseline measurements, in suppressed and natural blinking conditions, were taken before subjects were fitted with two different daily contact lenses and after four hours of contact lens wear. The method for analysing the stability of the tear film provides alternative parameters to the non-invasive break up time to assess the quality of the pre-corneal and pre-lens tear film. Both contact lenses significantly decreased the quality of the tear film in suppressed and natural blinking conditions (p<0.001). The utilised method was able to distinguish between contact lens materials on eye in suppressed blinking conditions. The pre-corneal tear film characteristics were not correlated with the decrease in pre-lens tear film quality. High-speed videokeratoscopy equipped with an automated method to analyse the dynamics of the tear film is able to distinguish between contact lens materials in vivo. Incorporating the assessment of pre-lens tear film to the clinical practice could aid improving contact lens fitting and understand contact lens comfort. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  2. Increasing age and tear size reduce rotator cuff repair healing rate at 1 year.

    PubMed

    Rashid, Mustafa S; Cooper, Cushla; Cook, Jonathan; Cooper, David; Dakin, Stephanie G; Snelling, Sarah; Carr, Andrew J

    2017-12-01

    Background and purpose - There is a need to understand the reasons why a high proportion of rotator cuff repairs fail to heal. Using data from a large randomized clinical trial, we evaluated age and tear size as risk factors for failure of rotator cuff repair. Patients and methods - Between 2007 and 2014, 65 surgeons from 47 hospitals in the National Health Service (NHS) recruited 447 patients with atraumatic rotator cuff tendon tears to the United Kingdom Rotator Cuff Trial (UKUFF) and 256 underwent rotator cuff repair. Cuff integrity was assessed by imaging in 217 patients, at 12 months post-operation. Logistic regression analysis was used to determine the influence of age and intra-operative tear size on healing. Hand dominance, sex, and previous steroid injections were controlled for. Results - The overall healing rate was 122/217 (56%) at 12 months. Healing rate decreased with increasing tear size (small tears 66%, medium tears 68%, large tears 47%, and massive tears 27% healed). The mean age of patients with a healed repair was 61 years compared with 64 years for those with a non-healed repair. Mean age increased with larger tear sizes (small tears 59 years, medium tears 62 years, large tears 64 years, and massive tears 66 years). Increasing age was an independent factor that negatively influenced healing, even after controlling for tear size. Only massive tears were an independent predictor of non-healing, after controlling for age. Interpretation - Although increasing age and larger tear size are both risks for failure of rotator cuff repair healing, age is the dominant risk factor.

  3. 3D resistivity survey for shallow subsurface fault investigations

    NASA Astrophysics Data System (ADS)

    Petrit, Kraipat; Klamthim, Poonnapa; Duerrast, Helmut

    2018-03-01

    The shallow subsurface is subject to various human activities, and the place of occurrence of geohazards, e.g. shallow active faults. The identification of the location and orientation of such faults can be vital for infrastructure development. The aim of this study was to develop a low-cost 3D resistivity survey system, with reasonable survey time for shallow fault investigations. The study area in Songkhla Province, Thailand is located in an old quarry where faults could be identified in outcrops. The study area was designed to cover the expected fault with 100 electrodes arranged in a 10×10 square grid with an electrode spacing of 3 meters in x and y axis. Each electrode in turn was used as a current and potential electrode using a dipole-dipole array. Field data have been processed and interpreted using 3DResINV. Results, presented in horizontal depth slices and vertical xz- and yz-cross sections, revealed through differences in resistivity down to 8 m depths a complex structural setting with two shallow faults and dipping sedimentary rock layers. In conclusion, this study has shown that a 3D resistivity survey can imagine complex tectonic structures, thus providing a far more insight into the shallow subsurface.

  4. 3D Constraints On Fault Architecture and Strain Distribution of the Newport-Inglewood Rose Canyon and San Onofre Trend Fault Systems

    NASA Astrophysics Data System (ADS)

    Holmes, J. J.; Driscoll, N. W.; Kent, G. M.

    2017-12-01

    The Inner California Borderlands (ICB) is situated off the coast of southern California and northern Baja. The structural and geomorphic characteristics of the area record a middle Oligocene transition from subduction to microplate capture along the California coast. Marine stratigraphic evidence shows large-scale extension and rotation overprinted by modern strike-slip deformation. Geodetic and geologic observations indicate that approximately 6-8 mm/yr of Pacific-North American relative plate motion is accommodated by offshore strike-slip faulting in the ICB. The farthest inshore fault system, the Newport-Inglewood Rose Canyon (NIRC) Fault is a dextral strike-slip system that is primarily offshore for approximately 120 km from San Diego to the San Joaquin Hills near Newport Beach, California. Based on trenching and well data, the NIRC Fault Holocene slip rate is 1.5-2.0 mm/yr to the south and 0.5-1.0 mm/yr along its northern extent. An earthquake rupturing the entire length of the system could produce an Mw 7.0 earthquake or larger. West of the main segments of the NIRC Fault is the San Onofre Trend (SOT) along the continental slope. Previous work concluded that this is part of a strike-slip system that eventually merges with the NIRC Fault. Others have interpreted this system as deformation associated with the Oceanside Blind Thrust Fault purported to underlie most of the region. In late 2013, we acquired the first high-resolution 3D Parallel Cable (P-Cable) seismic surveys of the NIRC and SOT faults as part of the Southern California Regional Fault Mapping project. Analysis of stratigraphy and 3D mapping of this new data has yielded a new kinematic fault model of the area that provides new insight on deformation caused by interactions in both compressional and extensional regimes. For the first time, we can reconstruct fault interaction and investigate how strain is distributed through time along a typical strike-slip margin using 3D constraints on fault

  5. Multi-Fault Rupture Scenarios in the Brawley Seismic Zone

    NASA Astrophysics Data System (ADS)

    Kyriakopoulos, C.; Oglesby, D. D.; Rockwell, T. K.; Meltzner, A. J.; Barall, M.

    2017-12-01

    event. For that reason, we are investigating scenarios of a moderate rupture on a cross fault, and determining conditions under which the rupture will propagate onto the adjacent SSAF. Our investigation will provide fundamental insights that may help us interpret faulting behaviors in other areas, such as the complex Mw 7.8 2016 Kaikoura (New Zealand) earthquake.

  6. Evolution of fault zones in carbonates with mechanical stratigraphy - Insights from scale models using layered cohesive powder

    NASA Astrophysics Data System (ADS)

    van Gent, Heijn W.; Holland, Marc; Urai, Janos L.; Loosveld, Ramon

    2010-09-01

    We present analogue models of the formation of dilatant normal faults and fractures in carbonate fault zones, using cohesive hemihydrate powder (CaSO 4·½H 2O). The evolution of these dilatant fault zones involves a range of processes such as fragmentation, gravity-driven breccia transport and the formation of dilatant jogs. To allow scaling to natural prototypes, extensive material characterisation was done. This showed that tensile strength and cohesion depend on the state of compaction, whereas the friction angle remains approximately constant. In our models, tensile strength of the hemihydrate increases with depth from 9 to 50 Pa, while cohesion increases from 40 to 250 Pa. We studied homogeneous and layered material sequences, using sand as a relatively weak layer and hemihydrate/graphite mixtures as a slightly stronger layer. Deformation was analyzed by time-lapse photography and Particle Image Velocimetry (PIV) to calculate the evolution of the displacement field. With PIV the initial, predominantly elastic deformation and progressive localization of deformation are observed in detail. We observed near-vertical opening-mode fractures near the surface. With increasing depth, dilational shear faults were dominant, with releasing jogs forming at fault-dip variations. A transition to non-dilatant shear faults was observed near the bottom of the model. In models with mechanical stratigraphy, fault zones are more complex. The inferred stress states and strengths in different parts of the model agree with the observed transitions in the mode of deformation.

  7. The Changes of Tear Status after Conventional and Wavefront-Guided IntraLASIK

    PubMed Central

    Foo, Say Kiang; Kaur, Sharanjeet; Abd Manan, Faudziah; Low, Aloysius Joseph

    2011-01-01

    Background: IntraLASIK is a LASIK surgery that involved IntraLase femtosecond laser for the corneal flap creating. The objective of this research was to investigate and compare the changes in tear status at 1 and 3 months after undergoing conventional IntraLASIK with Bausch & Lomb PlanoScan (PS) algorithm, Bausch & Lomb Zyoptix Tissue Saving (ZTS) algorithm, and wavefront-guided (WG) IntraLASIK with VISX CustomVue. Methods: Tear status of 36 patients who were divided into 3 groups depending on the type of IntraLASIK they underwent (PS, n = 13; ZTS, n = 9; WG, n = 14) was evaluated. Tear status was determined by classifying the category of the thickness of pre-corneal tear lipid layer, non-invasive tear break-up time, and tear meniscus height. Repeated measures analysis of variance (ANOVA) and one way ANOVA were used for the statistical analyses. Results: The category of the thickness of tear lipid layer, non-invasive tear break up time and tear meniscus height were neither significantly changed after IntraLASIK for all groups nor showed significant difference among groups at 1 and 3 months post-IntraLASIK (P > 0.05). Blinking rate and palpebral aperture also had no significant changed after IntraLASIK. Conclusion: Both conventional (PS and ZTS) and WG IntraLASIK did not affect tear status up to 3 months post-IntraLASIK. WG IntraLASIK did not show superiority in preserving tear status 1 and 3 months post-surgery compared with conventional IntraLASIK. PMID:22135584

  8. Complete vs partial-thickness tears of the posterior cruciate ligament: MR findings.

    PubMed

    Patten, R M; Richardson, M L; Zink-Brody, G; Rolfe, B A

    1994-01-01

    We sought to define the MRI appearance of both complete and partial-thickness tears of the posterior cruciate ligament (PCL) and to describe patterns of injury and associated MRI findings. Three radiologists retrospectively reviewed MR images and medical records on 32 patients with PCL tears (15 complete, 17 partial) and correlated MRI findings to results of clinical testing and surgery. The PCL had indistinct margins in 27 (84%) of 32 patients and was abnormally thick in 25 (78%) patients. In 31 (97%) patients, the torn PCL showed increased signal intensity on both T1- and T2-weighted pulse sequences. Although there was no statistically significant difference between patients with complete tears and those with partial tears with regard to thickness, margination, and signal intensity of the PCL, MR images in patients with complete tears were more likely to show focal areas of ligamentous discontinuity (10 of 15 cases) (p = 0.01). Associated knee injuries were seen in 21 (66%) patients and were seen more frequently in patients with complete PCL tears (p = 0.015). Bony injury (n = 11, 34%) and tears of the medial collateral ligament (n = 13, 41%) and menisci (n = 10, 31%) were common. No specific pattern of bony injury was found. Posterior cruciate ligament tears can be diagnosed readily by multiplanar MRI using both morphological and signal intensity characteristics. Although differentiation between complete and partial-thickness PCL tears by MRI criteria alone is more problematic, complete tears are more likely to show focal areas of discontinuity and partial tears are more likely to show at least some intact fibers.

  9. 3D fault curvature and fractal roughness: Insights for rupture dynamics and ground motions using a Discontinous Galerkin method

    NASA Astrophysics Data System (ADS)

    Ulrich, Thomas; Gabriel, Alice-Agnes

    2017-04-01

    Natural fault geometries are subject to a large degree of uncertainty. Their geometrical structure is not directly observable and may only be inferred from surface traces, or geophysical measurements. Most studies aiming at assessing the potential seismic hazard of natural faults rely on idealised shaped models, based on observable large-scale features. Yet, real faults are wavy at all scales, their geometric features presenting similar statistical properties from the micro to the regional scale. Dynamic rupture simulations aim to capture the observed complexity of earthquake sources and ground-motions. From a numerical point of view, incorporating rough faults in such simulations is challenging - it requires optimised codes able to run efficiently on high-performance computers and simultaneously handle complex geometries. Physics-based rupture dynamics hosted by rough faults appear to be much closer to source models inverted from observation in terms of complexity. Moreover, the simulated ground-motions present many similarities with observed ground-motions records. Thus, such simulations may foster our understanding of earthquake source processes, and help deriving more accurate seismic hazard estimates. In this presentation, the software package SeisSol (www.seissol.org), based on an ADER-Discontinuous Galerkin scheme, is used to solve the spontaneous dynamic earthquake rupture problem. The usage of tetrahedral unstructured meshes naturally allows for complicated fault geometries. However, SeisSol's high-order discretisation in time and space is not particularly suited for small-scale fault roughness. We will demonstrate modelling conditions under which SeisSol resolves rupture dynamics on rough faults accurately. The strong impact of the geometric gradient of the fault surface on the rupture process is then shown in 3D simulations. Following, the benefits of explicitly modelling fault curvature and roughness, in distinction to prescribing heterogeneous initial

  10. From current-driven to neoclassically driven tearing modes.

    PubMed

    Reimerdes, H; Sauter, O; Goodman, T; Pochelon, A

    2002-03-11

    In the TCV tokamak, the m/n = 2/1 island is observed in low-density discharges with central electron-cyclotron current drive. The evolution of its width has two distinct growth phases, one of which can be linked to a "conventional" tearing mode driven unstable by the current profile and the other to a neoclassical tearing mode driven by a perturbation of the bootstrap current. The TCV results provide the first clear observation of such a destabilization mechanism and reconcile the theory of conventional and neoclassical tearing modes, which differ only in the dominant driving term.

  11. Patterns of meniscal tears associated with anterior cruciate ligament lesions in athletes.

    PubMed

    Binfield, P M; Maffulli, N; King, J B

    1993-09-01

    In this study, 400 clinically anterior cruciate ligament (ACL) deficient knees were arthroscoped and studied prospectively in the period January 1986 to April 1992. An ACL tear was always confirmed, and 41 per cent of these patients did not have an associated meniscal tear. In 30.25 per cent the lateral meniscus was torn; in 21.25 per cent the ACL tear was associated with a medial meniscus tear, and in the remaining 7 per cent both menisci were torn. The most frequently associated meniscal injury was the bucket handle tear of the medial meniscus (9 per cent), followed by the posterior horn tear of the lateral meniscus, which showed the same frequency as the ragged (or degenerated) tear of the lateral meniscus (6 per cent). The horizontal tear of the posterior part of the lateral meniscus showed a prevalence of 4.3 per cent. This picture is probably dependent on a secondary referral nature of the centre surveyed, in which the average time between injury and arthroscopy was 23.3 months.

  12. Acetabular labral tears in patients with sports injury.

    PubMed

    Kang, Chan; Hwang, Deuk-Soo; Cha, Soo-Min

    2009-12-01

    We wanted to investigate acetabular labral tears and their correlation with femoroacetabular impingement in patients with sports injury. Among 111 patients who were diagnosed with the acetabular labral tears after arthroscopic treatment from January 2004 to December 2007, we selected 41 patients with sports injury. There were 12 cases of Taekwondo injury, 5 of golf injury, 4 of soccer injury, 3 of gymnastics injury, 2 of Hapkido injury, 2 of aerobics injury, 2 of rock-climbing injury, 2 of fitness training injury and 9 of other sports injuries. We checked the subtypes of acetabular labral tears and the accompanying femoroacetabular impingement. For the cases with accompanying femoroacetabular impingement, we investigated the subtypes according to the types of sports, gender and age. At last follow-up, we checked the Harris Hip Score (HHS), the Hip Outcome Score (HOS) sports scale and the percentage of patients who returned to their sports activity. The average age of symptomatic onset was 26 years (range, 12 to 65 years). The ratio of males to females was 29 : 12. An average duration of the hip pain was 17 months (range, 1 to 60 months). The degenerative type of acetabular labral tears was the most prevalent with 32 cases (78%), and there were 9 cases (22%) of the partial tear type. Thirty cases (73%) were accompanied by femoroacetabular impingement. The average age of the 23 cases (56%) of the cam-type was 23 years (range, 12 to 48 years), and it was more likely to occur in men (87%) and for people practicing martial arts such as Taekwondo or Hapkido. An average age of the 5 cases (12%) of the pincer-type was 26 (range, 16 to 43 years), it usually occurred in women (60%) and for non-martial arts such as golf and gymnastics. There were 2 cases of the mixed type (cam + pincer-type). At 27 months follow-up, the HHS was 61 to 92 points, the HOS sports scale increased 43 to 75%, and the rate of returning to sports was 71%. In spite of the early expression of symptoms

  13. Increasing age and tear size reduce rotator cuff repair healing rate at 1 year

    PubMed Central

    Rashid, Mustafa S; Cooper, Cushla; Cook, Jonathan; Cooper, David; Dakin, Stephanie G; Snelling, Sarah; Carr, Andrew J

    2017-01-01

    Background and purpose — There is a need to understand the reasons why a high proportion of rotator cuff repairs fail to heal. Using data from a large randomized clinical trial, we evaluated age and tear size as risk factors for failure of rotator cuff repair. Patients and methods — Between 2007 and 2014, 65 surgeons from 47 hospitals in the National Health Service (NHS) recruited 447 patients with atraumatic rotator cuff tendon tears to the United Kingdom Rotator Cuff Trial (UKUFF) and 256 underwent rotator cuff repair. Cuff integrity was assessed by imaging in 217 patients, at 12 months post-operation. Logistic regression analysis was used to determine the influence of age and intra-operative tear size on healing. Hand dominance, sex, and previous steroid injections were controlled for. Results — The overall healing rate was 122/217 (56%) at 12 months. Healing rate decreased with increasing tear size (small tears 66%, medium tears 68%, large tears 47%, and massive tears 27% healed). The mean age of patients with a healed repair was 61 years compared with 64 years for those with a non-healed repair. Mean age increased with larger tear sizes (small tears 59 years, medium tears 62 years, large tears 64 years, and massive tears 66 years). Increasing age was an independent factor that negatively influenced healing, even after controlling for tear size. Only massive tears were an independent predictor of non-healing, after controlling for age. Interpretation — Although increasing age and larger tear size are both risks for failure of rotator cuff repair healing, age is the dominant risk factor. PMID:28880113

  14. Interferometer for measuring the dynamic surface topography of a human tear film

    NASA Astrophysics Data System (ADS)

    Primeau, Brian C.; Greivenkamp, John E.

    2012-03-01

    The anterior refracting surface of the eye is the thin tear film that forms on the surface of the cornea. Following a blink, the tear film quickly smoothes and starts to become irregular after 10 seconds. This irregularity can affect comfort and vision quality. An in vivo method of characterizing dynamic tear films has been designed based upon a near-infrared phase-shifting interferometer. This interferometer continuously measures light reflected from the tear film, allowing sub-micron analysis of the dynamic surface topography. Movies showing the tear film behavior can be generated along with quantitative metrics describing changes in the tear film surface. This tear film measurement allows analysis beyond capabilities of typical fluorescein visual inspection or corneal topography and provides better sensitivity and resolution than shearing interferometry methods. The interferometer design is capable of identifying features in the tear film much less than a micron in height with a spatial resolution of about ten microns over a 6 mm diameter. This paper presents the design of the tear film interferometer along with the considerations that must be taken when designing an interferometer for on-eye diagnostics. Discussions include eye movement, design of null optics for a range of ocular geometries, and laser emission limits for on-eye interferometry.

  15. Association Between Contact Lens Discomfort and Pre-lens Tear Film Kinetics.

    PubMed

    Guillon, Michel; Dumbleton, Kathryn A; Theodoratos, Panagiotis; Wong, Stephanie; Patel, Kishan; Banks, Gaidig; Patel, Trisha

    2016-08-01

    The relationship between contact lens wettability and comfort has been extensively evaluated; however, a direct correlation between the characteristics of the pre-lens tear film and the symptoms associated with contact lens discomfort has yet to be established. In addition, there is relatively limited knowledge relating to the entire tear film kinetics during the inter-blink period in contact lens wearers. The purpose of this analysis was to identify the characteristics of the pre-lens tear film kinetics that may be associated with the symptoms of contact lens discomfort. The study population comprised 202 soft (hydrogel and silicone hydrogel) contact lens wearers attending pre-screening visits at the OTG-i research clinic. All participants completed the Ocular Surface Disease Index (OSDI) questionnaire and the tear film was quantified via post hoc, masked analysis of high definition digital Tearscope videos recorded at the visit. The tear film kinetics of the least symptomatic wearers (OSDI lowest quintile scores, n = 45) were compared to the tear film kinetics of the most symptomatic wearers (OSDI highest quintile scores, n = 43). The hypothesis tested was that the tear film kinetics of asymptomatic wearers were better than tear film kinetics of symptomatic wearers. The distribution of lens types worn was as follows: Daily Disposable 46.5%, 1-Month Replacement 39.6%, and 2-Week Replacement 13.6%. 48.2% of lenses were silicone hydrogel and 51.8% hydrogel. Symptomatic wearers had a shorter break-up time (4.7 s vs. 6.0 s; p = 0.003), lesser surface coverage by the tear film during the interblink period (95.1% vs. 98.5%; p < 0.001) and greater surface exposure at the time of the blink (9.4% vs. 3.9%; p = 0.001). The current study demonstrated that the tear film kinetics of asymptomatic and symptomatic contact lens wearers were different, the findings supporting the hypothesis of poorer tear film kinetics for symptomatic than asymptomatic wearers in a general contact

  16. New Insight into the Role of Tectonics versus Gravitational Deformation in Development of Surface Ruptures along the Ragged Mountain Fault, Katalla, Alaska USA: Applications of High-Resolution Three-Dimensional Terrain Models

    NASA Astrophysics Data System (ADS)

    Heinlein, S. N.; Pavlis, T. L.; Bruhn, R. L.; McCalpin, J. P.

    2017-12-01

    This study evaluates a surface structure using 3D visualization of LiDAR and aerial photography then analyzes these datasets using structure mapping techniques. Results provide new insight into the role of tectonics versus gravitational deformation. The study area is located in southern Alaska in the western edge of the St. Elias Orogen where the Yakutat microplate is colliding into Alaska. Computer applications were used to produce 3D terrain models to create a kinematic assessment of the Ragged Mountain fault which trends along the length of the east flank of Ragged Mountain. The area contains geomorphic and structural features which are utilize to determine the type of displacement on the fault. Previous studies described the Ragged Mountain fault as a very shallow (8°), west-dipping thrust fault that reactivated in the Late Holocene by westward-directed gravity sliding and inferred at least 180 m of normal slip, in a direction opposite to the (relative) eastward thrust transport of the structure inferred from stratigraphic juxtaposition. More recently this gravity sliding hypothesis has been questioned and this study evaluates one of these alternative hypotheses; that uphill facing normal fault-scarps along the Ragged Mountain fault trace represent extension above a buried ramp in a thrust and is evaluated with a fault-parallel flow model of hanging-wall folding and extension. Profiles across the scarp trace were used to illustrate the curvature of the topographic surfaces adjacent to the scarps system and evaluate their origin. This simple kinematic model tests the hypothesis that extensional fault scarps at the surface are produced by flexure above a deeper ramp in a largely blind thrust system. The data in the context of this model implies that the extensional scarp structures previously examined represent a combination of erosionally modified features overprinted by flexural extension above a thrust system. Analyses of scarp heights along the structure are

  17. Interacting faults

    NASA Astrophysics Data System (ADS)

    Peacock, D. C. P.; Nixon, C. W.; Rotevatn, A.; Sanderson, D. J.; Zuluaga, L. F.

    2017-04-01

    The way that faults interact with each other controls fault geometries, displacements and strains. Faults rarely occur individually but as sets or networks, with the arrangement of these faults producing a variety of different fault interactions. Fault interactions are characterised in terms of the following: 1) Geometry - the spatial arrangement of the faults. Interacting faults may or may not be geometrically linked (i.e. physically connected), when fault planes share an intersection line. 2) Kinematics - the displacement distributions of the interacting faults and whether the displacement directions are parallel, perpendicular or oblique to the intersection line. Interacting faults may or may not be kinematically linked, where the displacements, stresses and strains of one fault influences those of the other. 3) Displacement and strain in the interaction zone - whether the faults have the same or opposite displacement directions, and if extension or contraction dominates in the acute bisector between the faults. 4) Chronology - the relative ages of the faults. This characterisation scheme is used to suggest a classification for interacting faults. Different types of interaction are illustrated using metre-scale faults from the Mesozoic rocks of Somerset and examples from the literature.

  18. Comparison of non-invasive tear film stability measurement techniques.

    PubMed

    Wang, Michael Tm; Murphy, Paul J; Blades, Kenneth J; Craig, Jennifer P

    2018-01-01

    Measurement of tear film stability is commonly used to give an indication of tear film quality but a number of non-invasive techniques exists within the clinical setting. This study sought to compare three non-invasive tear film stability measurement techniques: instrument-mounted wide-field white light clinical interferometry, instrument-mounted keratoscopy and hand-held keratoscopy. Twenty-two subjects were recruited in a prospective, randomised, masked, cross-over study. Tear film break-up or thinning time was measured non-invasively by independent experienced examiners, with each of the three devices, in a randomised order, within an hour. Significant correlation was observed between instrument-mounted interferometric and keratoscopic measurements (p < 0.001) but not between the hand-held device and the instrument-mounted techniques (all p > 0.05). Tear film stability values obtained from the hand-held device were significantly shorter and demonstrated narrower spread than the other two instruments (all p < 0.05), while no significant differences were observed between the two instrument-mounted devices (all p > 0.05). Good clinical agreement exists between the instrument-mounted interferometric and keratoscopic measurements but not between the hand-held device and either of the instrument-mounted techniques. The results highlight the importance of specifying the instrument employed to record non-invasive tear film stability. © 2017 Optometry Australia.

  19. Artificially modified collagen fibril orientation affects leather tear strength.

    PubMed

    Kelly, Susyn J; Wells, Hannah C; Sizeland, Katie H; Kirby, Nigel; Edmonds, Richard L; Ryan, Tim; Hawley, Adrian; Mudie, Stephen; Haverkamp, Richard G

    2018-07-01

    Ovine leather has around half the tear strength of bovine leather and is therefore not suitable for high-value applications such as shoes. Tear strength has been correlated with the natural collagen fibril alignment (orientation index, OI). It is hypothesized that it could be possible to artificially increase the OI of the collagen fibrils and that an artificial increase in OI could increase tear strength. Ovine skins, after pickling and bating, were strained biaxially during chrome tanning. The strain ranged from 2 to 15% of the initial sample length, either uniformly in both directions by 10% or with 3% in one direction and 15% in the other. Once tanned, the leather tear strengths were measured and the collagen fibril orientation was measured using synchrotron-based small-angle X-ray scattering. The OI increased as a result of strain during tanning from 0.48 to 0.79 (P = 0.001) measured edge-on and the thickness-normalized tear strength increased from 27 to 43 N mm -1 (P < 0.001) after leather was strained 10% in two orthogonal directions. This is evidence to support a causal relationship between high OI (measured edge-on), highly influenced by thickness, and tear strength. It also provides a method to produce stronger leather. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  20. Earthquakes and aseismic creep associated with growing fault-related folds

    NASA Astrophysics Data System (ADS)

    Burke, C. C.; Johnson, K. M.

    2017-12-01

    Blind thrust faults overlain by growing anticlinal folds pose a seismic risk to many urban centers in the world. A large body of research has focused on using fold and growth strata geometry to infer the rate of slip on the causative fault and the distribution of off-fault deformation. However, because we have had few recorded large earthquakes on blind faults underlying folds, it remains unclear how much of the folding occurs during large earthquakes or during the interseismic period accommodated by aseismic creep. Numerous kinematic and mechanical models as well as field observations demonstrate that flexural slip between sedimentary layering is an important mechanism of fault-related folding. In this study, we run boundary element models of flexural-slip fault-related folding to examine the extent to which energy is released seismically or aseismically throughout the evolution of the fold and fault. We assume a fault imbedded in viscoelastic mechanical layering under frictional contact. We assign depth-dependent frictional properties and adopt a rate-state friction formulation to simulate slip over time. We find that in many cases, a large percentage (greater than 50%) of fold growth is accomplished by aseismic creep at bedding and fault contacts. The largest earthquakes tend to occur on the fault, but a significant portion of the seismicity is distributed across bedding contacts through the fold. We are currently working to quantify these results using a large number of simulations with various fold and fault geometries. Result outputs include location, duration, and magnitude of events. As more simulations are completed, these results from different fold and fault geometries will provide insight into how much folding occurs from these slip events. Generalizations from these simulations can be compared with observations of active fault-related folds and used in the future to inform seismic hazard studies.

  1. Fault-controlled development of shallow hydrothermal systems: Structural and mineralogical insights from the Southern Andes

    NASA Astrophysics Data System (ADS)

    Roquer, T.; Arancibia, G.; Rowland, J. V.; Iturrieta, P. C.; Morata, D.; Cembrano, J. M.

    2017-12-01

    Paleofluid-transporting systems can be recognized as meshes of fracture-filled veins in eroded zones of extinct hydrothermal systems. Here we conducted meso-microstructural analysis and mechanical modeling from two exhumed exposures of the faults governing regional tectonics of the Southern Andes: the Liquiñe-Ofqui Fault System (LOFS) and the Andean Transverse Faults (ATF). A total of 107 fractures in both exposures were analyzed. The ATF specific segment shows two tectonic solutions that can be modeled as Andersonian and non-Andersonian tectonic regimes: (1) shear (mode II/III) failure occurs at differential stresses > 28 MPa and fluid pressures < 40-80% lithostatic in the Andersonian regime; and (2) sporadic hybrid extensional + shear (modes I + II/III) failure occurs at differential stresses < 20 MPa and anomalously high fluid pressures > 85-98% lithostatic in the non-Andersonian regime. Additionally, the LOFS exposure cyclically fails in extension (mode I) or extension + shear (modes I + II/III) in the Andersonian regime, at differential stresses < 28 MPa and fluid pressures > 40-80% lithostatic. In areas of spatial interaction between ATF and LOFS, these conditions might favor: (1) the storage of overpressured fluids in hydrothermal systems associated with the ATF faults, and (2) continuous fluid flow through vertical conduits in the LOFS faults. These observations suggest that such intersections are highly probable locations for concentrated hydrothermal activity, which must be taken into consideration for further geothermal exploration. ACKNOWLEDGEMENTS. PhD CONICYT grants, Centro de Excelencia en Geotermia de los Andes (CEGA-FONDAP/CONICYT Project #15090013), FONDECYT Project #1130030 and Project CONICYT REDES #140036.

  2. Fault recovery characteristics of the fault tolerant multi-processor

    NASA Technical Reports Server (NTRS)

    Padilla, Peter A.

    1990-01-01

    The fault handling performance of the fault tolerant multiprocessor (FTMP) was investigated. Fault handling errors detected during fault injection experiments were characterized. In these fault injection experiments, the FTMP disabled a working unit instead of the faulted unit once every 500 faults, on the average. System design weaknesses allow active faults to exercise a part of the fault management software that handles byzantine or lying faults. It is pointed out that these weak areas in the FTMP's design increase the probability that, for any hardware fault, a good LRU (line replaceable unit) is mistakenly disabled by the fault management software. It is concluded that fault injection can help detect and analyze the behavior of a system in the ultra-reliable regime. Although fault injection testing cannot be exhaustive, it has been demonstrated that it provides a unique capability to unmask problems and to characterize the behavior of a fault-tolerant system.

  3. Spatial distribution of damage around faults in the Joe Lott Tuff Member of the Mount Belknap Volcanics, Utah: A mechanical analog for faulting in pyroclastic deposits on Mars

    USGS Publications Warehouse

    Okubo, Chris H.

    2012-01-01

    Volcanic ash is thought to comprise a large fraction of the Martian equatorial layered deposits and much new insight into the process of faulting and related fluid flow in these deposits can be gained through the study of analogous terrestrial tuffs. This study identifies a set of fault-related processes that are pertinent to understanding the evolution of fault systems in fine-grained, poorly indurated volcanic ash by investigating exposures of faults in the Miocene-aged Joe Lott Tuff Member of the Mount Belknap Volcanics, Utah. The porosity and granularity of the host rock are found to control the style of localized strain that occurs prior to and contemporaneous with faulting. Deformation bands occur in tuff that was porous and granular at the time of deformation, while fractures formed where the tuff lost its porous and granular nature due to silicic alteration. Non-localized deformation of the host rock is also prominent and occurs through compaction of void space, including crushing of pumice clasts. Significant off-fault damage of the host rock, resembling fault pulverization, is recognized adjacent to one analog fault and may reflect the strain rate dependence of the resulting fault zone architecture. These findings provide important new guidelines for future structural analyses and numerical modeling of faulting and subsurface fluid flow through volcanic ash deposits on Mars.

  4. Concentrations of MUC16 and MUC5AC using three tear collection methods

    PubMed Central

    Nichols, Jason J.

    2017-01-01

    Purpose To determine the optimal tear collection method for analysis of ocular surface mucins MUC5AC and MUC16. Methods Fifteen subjects without ocular surface disease were recruited. Subjects presented for tear collection on three separate days for three different tear collection methods with the order of method randomized. Methods used to collect tears from right and left eyes included Schirmer’s strip, basal tear collection, and flush tear collection. All samples from the right eyes were individually analyzed for MUC5AC whereas the left eye samples were individually analyzed for MUC16. For each individual sample, 10 μg of protein were loaded per lane into a 1% (w/v) agarose gel and run in electrophoresis buffer for 2 h. After overnight capillary transfer, membranes were incubated with either MUC5AC antibody CLH2 or MUC16 antibody OC125 for western blot analysis. Blots were developed with enhanced chemiluminescence (ECL) and signals captured with the Odyssey Fc (LI-COR). The relative amounts of MUC5AC and MUC16 were quantified with densitometry using software and compared for statistically significant differences between tear collection methods using the Kruskal–Wallis test in SPSS 22 and GraphPad Prism 7.02. Dunn’s multiple comparisons test was used for pairwise post-hoc comparisons. Results Samples containing less than 10 μg of total protein were not used for analysis which left eight samples (out of 45) unusable. The calculated MUC5AC median signal intensities from Schirmer’s strip, basal tears, and flush tears were 2.86 (n = 15, the interquartile range [IQR] = 2.54–3.21), 1.65 (n = 14, IQR = 1.34–3.1), and 1.67 (n = 9, IQR = 1.42–1.72), respectively (H = 9.5, p = 0.009). Post-hoc pairwise comparisons showed a statistically significant difference between Schirmer’s strip and flush tears (p = 0.01). The calculated MUC16 median signal intensities from Schirmer’s strip, basal tears, and flush tears were 1.88 (n = 14, IQR = 1.43–2.61), 5

  5. Slab tears and intermediate-depth seismicity

    USGS Publications Warehouse

    Meighan, Hallie E.; ten Brink, Uri S.; Pulliam, Jay

    2013-01-01

    Active tectonic regions where plate boundaries transition from subduction to strike slip can take several forms, such as triple junctions, acute, and obtuse corners. Well-documented slab tears that are associated with high rates of intermediate-depth seismicity are considered here: Gibraltar arc, the southern and northern ends of the Lesser Antilles arc, and the northern end of Tonga trench. Seismicity at each of these locations occurs, at times, in the form of swarms or clusters, and various authors have proposed that each marks an active locus of tear propagation. The swarms and clusters start at the top of the slab below the asthenospheric wedge and extend 30–60 km vertically downward within the slab. We propose that these swarms and clusters are generated by fluid-related embrittlement of mantle rocks. Focal mechanisms of these swarms generally fit the shear motion that is thought to be associated with the tearing process.

  6. The association between body fat and rotator cuff tear: the influence on rotator cuff tear sizes.

    PubMed

    Gumina, Stefano; Candela, Vittorio; Passaretti, Daniele; Latino, Gianluca; Venditto, Teresa; Mariani, Laura; Santilli, Valter

    2014-11-01

    Rotator cuff tear (RCT) has a multifactorial etiology. We hypothesized that obesity may increase the risk of RCT and influence tear size. A case-control design study was used. We studied 381 consecutive patients (180 men, 201 women; mean age ± standard deviation, 65.5 ± 8.52 years; range, 43-78 years) who underwent arthroscopic rotator cuff repair. Tear size was determined intraoperatively. The control group included 220 subjects (103 men, 117 women; mean age ± standard deviation, 65.16 ± 7.24 years; range, 42-77 years) with no RCT. Body weight, height, and bicipital, tricipital, subscapularis, and suprailiac skinfolds of all participants were measured to obtain body mass index (BMI) and the percentage of body fat (%BF). For the purposes of the study, the 601 participants were divided into 2 groups by BMI (group A, BMI ≥ 25; group B, BMI < 25). The odds ratios (ORs) were calculated to investigate whether adiposity affects the risk of RCT. Data were stratified according to gender and age. Multiple linear regression analyses were applied to explore the association between obesity and tear size. The highest ORs for both men (OR, 2.49; 95% confidence interval, 1.41-3.90; P = .0037) and women (OR, 2.31; 95% confidence interval, 1.38-3.62; P = .0071) were for individuals with a BMI ≥ 30; 69% (N = 303) of group A and 48% (N = 78) of group B had RCTs. Patients with RCT had a BMI higher than that of subjects with no RCT in both groups (P = .031, group A; P = .02, group B). BMI and %BF significantly increased from patients with a small tear (BMI, 27.85; %BF, 37.63) to those with a massive RCT (BMI, 29.93; %BF, 39.43). Significant differences were found (P = .004; P = .031). Our results provide evidence that obesity, measured through BMI and %BF, is a significant risk factor for the occurrence and severity of RCT. Copyright © 2014. Published by Elsevier Inc.

  7. Antibody Protein Array Analysis of the Tear Film Cytokines

    PubMed Central

    Li, Shimin; Sack, Robert; Vijmasi, Trinka; Sathe, Sonal; Beaton, Ann; Quigley, David; Gallup, Marianne; McNamara, Nancy A.

    2013-01-01

    Purpose Many bioactive proteins including cytokines are reported to increase in dry eye disease although the specific profile and concentration of inflammatory mediators varies considerably from study to study. In part this variability results from inherent difficulties in quantifying low abundance proteins in a limited sample volume using relatively low sensitivity dot ELISA methods. Additional complexity comes with the use of pooled samples collected using a variety of techniques and intrinsic variation in the diurnal pattern of individual tear proteins. The current study describes a recent advance in the area of proteomics that has allowed the identification of dozens of low abundance proteins in human tear samples. Methods Commercially available stationary phase antibody protein arrays were adapted to improve suitability for use in small volume biological fluid analysis with particular emphasis on tear film proteomics. Arrays were adapted to allow simultaneous screening for a panel of inflammatory cytokines in low volume tear samples collected from individual eyes. Results A preliminary study comparing tear array results in a small population of Sjögren’s syndrome patients was conducted. The multiplex microplate array assays of cytokines in tear fluid present an unanticipated challenge due to the unique nature of tear fluid. The presence of factors that exhibit an affinity for plastic, capture antibodies and IgG and create a complex series of matrix effects profoundly impacting the reliability of dot ELISA, including with elevated levels of background reactivity and reduction in capacity to bind targeted protein. Conclusions Preliminary results using tears collected from patients with Sjögren’s syndrome reveal methodological advantages of protein array technology and support the concept that autoimmune-mediated dry eye disease has an inflammatory component. They also emphasize the inherent difficulties one can face when interpreting the results of micro

  8. Glycan involvement in the adhesion of Pseudomonas aeruginosa to tears.

    PubMed

    Kautto, Liisa; Nguyen-Khuong, Terry; Everest-Dass, Arun; Leong, Andrea; Zhao, Zhenjun; Willcox, Mark D P; Packer, Nicolle H; Peterson, Robyn

    2016-04-01

    The human eye is constantly bathed by tears, which protect the ocular surface via a variety of mechanisms. The O-linked glycans of tear mucins have long been considered to play a role in binding to pathogens and facilitating their removal in the tear flow. Other conjugated glycans in tears could similarly contribute to pathogen binding and removal but have received less attention. In the work presented here we assessed the contribution of glycan moieties, in particular the protein attached N-glycans, presented by the broad complement of tear proteins to the adhesion of the opportunistic pathogen Pseudomonas aeruginosa, a leading cause of microbial keratitis and ulceration of the cornea. Our adhesion assay involved immobilising the macromolecular components of tears into the wells of a polyvinyl difluoride (PVDF) microtitre filter plate and probing the binding of fluorescently labelled bacteria. Three P. aeruginosa strains were studied: a cytotoxic strain (6206) and an invasive strain (6294) from eye infections, and an invasive strain (320) from a urinary tract infection (UTI). The ocular isolates adhered two to three times more to human tears than to human saliva or porcine gastric mucin, suggesting ocular niche-specific adaptation. Support for the role of the N-glycans carried by human tear proteins in the binding and removal of P. aeruginosa from the eye was shown by: 1) pre-incubation of the bacteria with free component sugars, galactose, mannose, fucose and sialyl lactose (or combination thereof) inhibiting adhesion of all the P. aeruginosa strains to the immobilised tear proteins, with the greatest inhibition of binding of the ocular cytotoxic 6206 and least for the invasive 6294 strain; 2) pre-incubation of the bacteria with N-glycans released from the commercially available human milk lactoferrin, an abundant protein that carries N-linked glycans in tears, inhibiting the adhesion to tears of the ocular bacteria by up to 70%, which was significantly more

  9. Predictive MRI correlates of lesser metatarsophalangeal joint plantar plate tear.

    PubMed

    Umans, Rachel L; Umans, Benjamin D; Umans, Hilary; Elsinger, Elisabeth

    2016-07-01

    To identify correlated signs on non-enhanced MRI that might improve diagnostic detection of plantar plate (PP) tear. We performed an IRB-approved, HIPAA-compliant retrospective analysis of 100 non-contrast MRI (50 PP tear, 50 controls). All were anonymized, randomized, and reviewed; 20 were duplicated to assess consistency. One musculoskeletal radiologist evaluated qualitative variables. A trained non-physician performed measurements. Consistency and concordance were assessed. Pearson's Chi-square test was used to test the correlation between qualitative findings and PP tear status. Correlation between measurements and PP status was assessed using t tests and Wilcoxon's rank-sum test (p values < 0.05 considered significant). Classification and regression trees were utilized to identify attributes that, taken together, would consistently distinguish PP tear from controls. Quantitative measurements were highly reproducible (concordance 0.88-0.99). Elevated 2nd MT protrusion, lesser MT supination and rotational divergence of >45° between the 1st-2nd MT axis correlated with PP tear. Pericapsular soft tissue thickening correlated most strongly with PP tear, correctly classifying 95 % of cases and controls. Excluding pericapsular soft tissue thickening, sequential assessment of 2nd toe enthesitis, 2nd flexor tendon subluxation, and splaying of the second and third toes accurately classified PP status in 92 %. Pericapsular soft tissue thickening most strongly correlated with PP tear. For cases in which it might be difficult to distinguish pericapsular fibrosis from neuroma, sequential assessment of 2nd toe enthesitis, flexor tendon subluxation and splaying of the 2nd and 3rd toe is most helpful for optimizing accurate diagnosis of PP tear.

  10. Does midwife experience affect the rate of severe perineal tears?

    PubMed

    Mizrachi, Yossi; Leytes, Sophia; Levy, Michal; Hiaev, Zvia; Ginath, Shimon; Bar, Jacob; Kovo, Michal

    2017-06-01

    Our aim was to study whether midwife experience affects the rate of severe perineal tears (3rd and 4th degree). A retrospective cohort study of all women with term vertex singleton pregnancies, who underwent normal vaginal deliveries, in a single tertiary hospital, between 2011 and 2015, was performed. Exclusion criteria were instrumental deliveries and stillbirth. All midwives used a "hands on" technique for protecting the perineum. The midwife experience at each delivery was calculated as the time interval between her first delivery and current delivery. A comparison was performed between deliveries in which midwife experience was less than 2 years (inexperienced), between 2 and 10 years (moderately experienced), and more than 10 years (highly experienced). A multivariate regression analysis was performed to assess the association between midwife experience and the incidence of severe perineal tears, after controlling for confounders. Overall, 15 146 deliveries were included. Severe perineal tears were diagnosed in 51 (0.33%) deliveries. Women delivered by inexperienced midwives had a higher rate of severe perineal tears compared with women delivered by highly experienced midwives (0.5% vs 0.2%, respectively, P=.024). On multivariate regression analysis, midwife experience was independently associated with a lower rate of severe perineal tears, after controlling for confounding factors. Each additional year of experience was associated with a 4.7% decrease in the risk of severe perineal tears (adjusted OR 0.95 [95% CI 0.91-0.99, P=.03). More experienced midwives had a lower rate of severe perineal tears, and may be preferred for managing deliveries of women at high risk for such tears. © 2017 Wiley Periodicals, Inc.

  11. The knee meniscus: management of traumatic tears and degenerative lesions

    PubMed Central

    Beaufils, Philippe; Becker, Roland; Kopf, Sebastian; Matthieu, Ollivier; Pujol, Nicolas

    2017-01-01

    Meniscectomy is one of the most popular orthopaedic procedures, but long-term results are not entirely satisfactory and the concept of meniscal preservation has therefore progressed over the years. However, the meniscectomy rate remains too high even though robust scientific publications indicate the value of meniscal repair or non-removal in traumatic tears and non-operative treatment rather than meniscectomy in degenerative meniscal lesions In traumatic tears, the first-line choice is repair or non-removal. Longitudinal vertical tears are a proper indication for repair, especially in the red-white or red-red zones. Success rate is high and cartilage preservation has been proven. Non-removal can be discussed for stable asymptomatic lateral meniscal tears in conjunction with anterior cruciate ligament (ACL) reconstruction. Extended indications are now recommended for some specific conditions: horizontal cleavage tears in young athletes, hidden posterior capsulo-meniscal tears in ACL injuries, radial tears and root tears. Degenerative meniscal lesions are very common findings which can be considered as an early stage of osteoarthritis in middle-aged patients. Recent randomised studies found that arthroscopic partial meniscectomy (APM) has no superiority over non-operative treatment. Thus, non-operative treatment should be the first-line choice and APM should be considered in case of failure: three months has been accepted as a threshold in the ESSKA Meniscus Consensus Project presented in 2016. Earlier indications may be proposed in cases with considerable mechanical symptoms. The main message remains: save the meniscus! Cite this article: EFORT Open Rev 2017;2. DOI: 10.1302/2058-5241.2.160056. Originally published online at www.efortopenreviews.org PMID:28698804

  12. Frictional and hydrologic behavior of the San Andreas Fault: Insights from laboratory experiments on SAFOD cuttings and core

    NASA Astrophysics Data System (ADS)

    Carpenter, B. M.; Marone, C.; Saffer, D. M.

    2010-12-01

    The debate concerning the apparent low strength of tectonic faults, including the San Andreas Fault (SAF), continues to focus on: 1) low intrinsic friction resulting from mineralogy and/or fabric, and 2) decreased effective normal stress due to elevated pore pressure. Here we inform this debate with laboratory measurements of the frictional behavior and permeability of cuttings and core returned from the SAF at a vertical depth of 2.7 km. We conducted experiments on cuttings and core recovered during SAFOD Phase III drilling. All samples in this study are adjacent to and within the active fault zone penetrated at 10814.5 ft (3296m) measured depth in the SAFOD borehole. We sheared gouge samples composed of drilling cuttings in a double-direct shear configuration subject to true-triaxial loading under constant effective normal stress, confining pressure, and pore pressure. Intact wafers of material were sheared in a single-direct shear configuration under similar conditions of effective stress, confining pressure, and pore pressure. We also report on permeability measurements on intact wafers of wall rock and fault gouge prior to shearing. Initial results from experiments on cuttings show: 1) a weak fault (µ=~0.21) compared to the surrounding wall rock (µ=~0.35), 2) velocity strengthening behavior, (a-b > 0), consistent with aseismic slip, and 3) near zero healing rates in material from the active fault. XRD analysis on cuttings indicates the main mineralogical difference between fault rock and wall rock, is the presence of significant amounts of smectite within the fault rock. Taken together, the measured frictional behavior and clay mineral content suggest that the clay composition exhibits a basic control on fault behavior. Our results document the first direct evidence of weak material from an active fault at seismogenic depths. In addition, our results could explain why the SAF in central California fails aseismically and hosts only small earthquakes.

  13. The brilliant beauty of the eye: light reflex from the cornea and tear film.

    PubMed

    Goto, Eiki

    2006-12-01

    Light reflex from the cornea and tear film as contributors to beautiful eyes ("eye sparkling") are reviewed. A systematic literature review was conducted using "Purkinje-Sanson image," "corneal light reflex," "corneal topography," "corneal wavefront aberration," and "tear interference image" as search terms. Articles on corneal surface regularity and stability and tear interferometry of the precorneal tear lipid layer were reviewed. PS-1 image, that is light reflex from the cornea and tear film, is widely used in practical ophthalmic examination. To achieve a brilliant beauty of the eye ("eye sparkling"), it is important that the tear film (aqueous layer) surface is smooth and stable with adequate tear volume and that the tear lipid layer is present in adequate thickness.

  14. Tear film proteome in age-related macular degeneration.

    PubMed

    Winiarczyk, Mateusz; Kaarniranta, Kai; Winiarczyk, Stanisław; Adaszek, Łukasz; Winiarczyk, Dagmara; Mackiewicz, Jerzy

    2018-06-01

    Age-related macular degeneration (AMD) is the main reason for blindness in elderly people in the developed countries. Current screening protocols have limitations in detecting the early signs of retinal degeneration. Therefore, it would be desirable to find novel biomarkers for early detection of AMD. Development of novel biomarkers would help in the prevention, diagnostics, and treatment of AMD. Proteomic analysis of tear film has shown promise in this research area. If an optimal set of biomarkers could be obtained from accessible body fluids, it would represent a reliable way to monitor disease progression and response to novel therapies. Tear films were collected on Schirmer strips from a total of 22 patients (8 with wet AMD, 6 with dry AMD, and 8 control individuals). 2D electrophoresis was used to separate tear film proteins prior to their identification with matrix-assisted laser desorption/ionization time of flight spectrometer (MALDI-TOF/TOF) and matching with functional databases. A total of 342 proteins were identified. Most of them were previously described in various proteomic studies concerning AMD. Shootin-1, histatin-3, fidgetin-like protein 1, SRC kinase signaling inhibitor, Graves disease carrier protein, actin cytoplasmic 1, prolactin-inducible protein 1, and protein S100-A7A were upregulated in the tear film samples isolated from AMD patients and were not previously linked with this disease in any proteomic analysis. The upregulated proteins supplement our current knowledge of AMD pathogenesis, providing evidence that certain specific proteins are expressed into the tear film in AMD. As far we are aware, this is the first study to have undertaken a comprehensive in-depth analysis of the human tear film proteome in AMD patients.

  15. Freezing Range, Melt Quality, and Hot Tearing in Al-Si Alloys

    NASA Astrophysics Data System (ADS)

    Uludağ, Muhammet; Çetin, Remzi; Dispinar, Derya

    2018-02-01

    In this study, three different aluminum-silicon alloys (A356, A413, and A380) that have different solidification morphology and solidification ranges were examined with an aim to evaluate the hot tearing susceptibility. T-shape mold and Constrained Rod Casting (CRC) mold were used for the characterization. Reduced Pressure Test (RPT) was used to quantify the casting quality by measuring bifilm index. It was found that bifilm index and solidification range have an important role on the hot tearing formation. As it is known, bifilms can cause porosity and in this case, it was shown that porosity formed by bifilms decreased hot tearing tendency. As the freezing range of alloy increases, bifilms find the time to unravel that reduces hot tearing. However, for eutectic alloy (A413), due to zero freezing range, regardless of bifilm content, hot tearing was never observed. A380.1 alloy had the highest tendency for hot tearing due to having the highest freezing range among the alloys investigated in this work.

  16. Mental Health Has a Stronger Association with Patient-Reported Shoulder Pain and Function Than Tear Size in Patients with Full-Thickness Rotator Cuff Tears.

    PubMed

    Wylie, James D; Suter, Thomas; Potter, Michael Q; Granger, Erin K; Tashjian, Robert Z

    2016-02-17

    Patient-reported outcome measures have increasingly accompanied objective examination findings in the evaluation of orthopaedic interventions. Our objective was to determine whether a validated measure of mental health (Short Form-36 Mental Component Summary [SF-36 MCS]) or measures of tear severity on magnetic resonance imaging were more strongly associated with self-assessed shoulder pain and function in patients with symptomatic full-thickness rotator cuff tears. One hundred and sixty-nine patients with full-thickness rotator cuff tears were prospectively enrolled. Patients completed the Short Form-36, visual analog scales for shoulder pain and function, the Simple Shoulder Test (SST), and the American Shoulder and Elbow Surgeons (ASES) instrument at the time of diagnosis. Shoulder magnetic resonance imaging examinations were reviewed to document the number of tendons involved, tear size, tendon retraction, and tear surface area. Age, sex, body mass index, number of medical comorbidities, smoking status, and Workers' Compensation status were recorded. Bivariate correlations and multivariate regression models were calculated to identify associations with baseline shoulder scores. The SF-36 MCS had the strongest correlation with the visual analog scale for shoulder pain (Pearson correlation coefficient, -0.48; p < 0.001), the visual analog scale for shoulder function (Pearson correlation coefficient, -0.33; p < 0.001), the SST (Pearson correlation coefficient, 0.37; p < 0.001), and the ASES score (Pearson correlation coefficient, 0.51; p < 0.001). Tear severity only correlated with the visual analog scale for shoulder function; the Pearson correlation coefficient was 0.19 for tear size (p = 0.018), 0.18 for tendon retraction (p = 0.025), 0.18 for tear area (p = 0.022), and 0.20 for the number of tendons involved (p = 0.011). Tear severity did not correlate with other scores in bivariate correlations (all p > 0.05). In all multivariate models, the SF-36 MCS had the

  17. Radiographic progression of arthritic changes in shoulders with degenerative rotator cuff tears.

    PubMed

    Chalmers, Peter N; Salazar, Dane H; Steger-May, Karen; Chamberlain, Aaron M; Stobbs-Cucchi, Georgia; Yamaguchi, Ken; Keener, Jay D

    2016-11-01

    Very little longitudinal information has been available regarding the relationship of cuff tears and arthritis. The purpose of this study was to determine the midterm risk of and risk factors for rotator cuff tear arthropathy progression in a cohort of subjects with an asymptomatic rotator cuff tear. Baseline (visit 1), 5-year (visit 2), and most recent follow-up (visit 3) radiographs were reviewed in a cohort of 105 subjects enrolled for longitudinal surveillance of asymptomatic degenerative rotator cuff tears and 33 controls. The radiographs were assessed in a blinded, randomized fashion by 3 observers who graded glenohumeral arthritic changes using the Hamada scores, Samilson-Prieto (SPO) scores, and acromiohumeral interval (AHI). Osteoarthritis (SPO classification), cuff tear arthropathy (Hamada classification), and AHI progressed between visits 1 and 3 (median, 8 years; P < .001 in all cases). SPO progression was not significantly different for partial- vs. full-thickness vs. control baseline tear types (P = .19). Both full-thickness and partial-thickness tears had greater progression in Hamada scores than controls did in the first 5 years of follow-up (P = .02 and P = .03, respectively), but scores did not differ between partial- and full-thickness tears. Tears with and without enlargement did not differ in progression in SPO grade, Hamada grade, or AHI. Glenohumeral arthritic changes progress significantly but remain minimal within an 8-year period in early to moderate degenerative cuff disease. Whereas the presence of a rotator cuff tear influences progression in Hamada grade, the magnitude of radiographic progression is not influenced by tear severity or enlargement at midterm time points. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  18. Reevaluation of 1935 M 7.0 earthquake fault, Miaoli-Taichung Area, western Taiwan: a DEM and field study

    NASA Astrophysics Data System (ADS)

    Lin, Y. N.; Chen, Y.; Ota, Y.

    2003-12-01

    A large earthquake (M 7.0) took place in Miaoli area, western Taiwan on April 21st, 1935. Right to its south is the 1999 Chi-Chi earthquake fault, indicating it is not only tectonically but seismically active. As the previous study, the study area is located in the mature zone of a tectonic collision that occurred between Philippine sea Plate and Eurasia continental Plate. The associated surface ruptures of 1935 earthquake daylighted Tungtsichiao Fault, a tear fault trending NE in the south and Chihhu Fault, a back thrust trending N-S in the north, but no ruptures occurred in between. Strike-slip component was identified by the horizontal offset observed along Tungtsichiao Fault; however, there are still disputes on the reported field evidence. Our purposes are (1) to identify the structural behaviors of these two faults, (2) to find out what the seismogenic structure is, and (3) to reconstruct the regional geology by information given by this earthquake. By DEM interpretation and field survey, we can clearly recognize a lot of the 1935 associated features. In the west of Chihhu Fault, a series of N-S higher terraces can be identified with eastward tilted surfaces and nearly 200 m relative height. Another lower terrace is also believed being created during the 1935 earthquake, showing an east-facing scarp with a height of ca. 1.5~2 m. Outcrop investigation reveals that the late-Miocene bedrock has been easterly thrusted over the Holocene conglomerates, indicating a west-dipping fault plane. The Tungtsichiao Fault cuts through a lateritic terrace at Holi, which is supposed developed in Pleistocene. The fault scarp is only discernible in the northeastern ending. Other noticeable features are the fault related antiforms that line up along the surface rupture. There is no outcrop to show the fault geometry among bedrocks. We re-interpret the northern Chihhu Fault as the back thrust generated from a main subsurface detachment, which may be the actual seismogenic fault

  19. Prevalence of triceps tendon tears on MRI of the elbow and clinical correlation.

    PubMed

    Koplas, Monica C; Schneider, Erika; Sundaram, Murali

    2011-05-01

    Triceps tendon injuries are reported to be very rare. To our knowledge, there have been no studies describing its prevalence or injury patterns on MR imaging. The purpose of this retrospective study was to determine the prevalence and patterns of triceps injuries based on a large series of consecutive MR examinations. Clinical correlation was obtained. From 801 consecutive elbow MR examinations over a 15-year period, 28 patients with 30 triceps tendon injuries were identified and graded as partial tendon tear and complete tendon tear. The patients' medical records were reviewed to determine age, gender, cause of tears, and management. The prevalence of triceps tendon injuries was 3.8%. There were 5 women and 23 men with partial or complete tears (mean age: 46.6 years; range: 2.7 to 75.1 years). The most common injury was partial tear, found in 18 patients. There were 10 patients with 12 complete tears (2 had re-torn following surgical repair). A tear was suspected in 12 out 28 (43%) patients prior to the MRI. The most common presenting symptom was pain. The most common cause was athletic injury (8 patients [29%], including weightlifting [2 patients]). Tendon tear was found to be a complication of infection in 6 patients, and in 3 patients the tears were a complication of steroid use. Thirteen tendon tears were surgically repaired (8 of these were complete tears). Triceps tendon injury is not as rare as commonly reported and may often be clinically underdiagnosed.

  20. Proteases, proteolysis and inflammatory molecules in the tears of people with keratoconus.

    PubMed

    Balasubramanian, Sivaraman Arumugam; Mohan, Sujatha; Pye, David Cecil; Willcox, Mark Duncan Perry

    2012-06-01

    To investigate the expression of proteases, proteolytic activity and cytokines in the tear film of people with keratoconus. Basal tears from people with keratoconus, from individuals who had undergone corneal collagen cross-linking for the treatment of keratoconus, and from normal controls were collected using a capillary tube. Corneal curvature of each subject was mapped. The total protein in tears was estimated. Levels and activity of proteases in the tears were analysed using specific antibody arrays and activity assays. The total tear protein level was significantly reduced in keratoconus (4.1 ± 0.9 mg/ml) compared with normals (6.7 ± 1.4 mg/ml) (p < 0.0001) or subjects who had undergone corneal collagen cross-linking (5.7 ± 2.3 mg/ml) (p < 0.005). Significantly (p < 0.05) increased tear expression of matrix metalloproteinases (MMP) -1, -3, -7, -13, interleukins (IL) -4, -5, -6, -8 and tumour necrosis factor (TNF) -α, -β were evident in keratoconus. Tear IL-6 was the only cytokine significantly (p < 0.05) increased in tears of keratoconus subjects compared with the collagen cross-linked group. No significant difference in tear proteases were observed between the normal and the cross-linked groups, although the expression of TNF-α was significantly (p < 0.05) increased in the cross-linked group compared with the controls. Elevated gelatinolytic (87.5 ± 33.6 versus 45.8 ± 24.6 FIU, p < 0.0001) and collagenolytic (6.1 ± 3.2 versus 3.6 ± 2.0 FIU, p < 0.05) activities were observed in tears from keratoconus compared with normal subjects. The activity of tear gelatinases (69.6 ± 22.2 FIU) and collagenases (5.7 ± 3.3 FIU) in the collagen cross-linked group was not significantly different compared with either keratoconus or normals. Tears of people with keratoconus had 1.9 times higher levels of proteolytic activity and over expression of several MMPs and cytokines compared with tears from controls. Further investigations are required to study the possible

  1. [Diagnostic value of MRI for posterior root tear of medial and lateral meniscus].

    PubMed

    Qian, Yue-Nan; Liu, Fang; Dong, Yi-Long; Cai, Chun-Yuan

    2018-03-25

    To explore diagnostic value of MRI on posterior root tear of medial and lateral meniscus. From January 2012 to January 2016, clinical data of 43 patients with meniscal posterior root tear confirmed by arthroscopy were retrospective analyzed, including 25 males and 18 females, aged from 27 to 69 years old with an average age of(42.5±8.3)years old;27 cases on the right side and 16 cases on the left side. MRI examinations of 43 patients with tear of posterior meniscus root confirmed by knee arthroscopies were retrospectively reviewed. MRI images were double-blinded, independently, retrospectively scored by two imaging physicians. Sensitivity, specificity and accuracy of MRI diagnosis of lateral and medial meniscus posterior root tear were calculated, and knee ligament injury and meniscal dislocation were calculated. Forty-three of 143 patients were diagnosed with meniscus posterior root tears by arthroscopy, including 19 patients with lateral tears and 24 patients with medial tears. The sensitivity, specificity and accuracy in diagnosis of posterior medial meniscus root tears for doctor A were 91.67%, 86.6% and 83.9% respectively, and for doctor B were 87.5%, 87.4% and 87.4%, 19 patients with medial meniscal protrusion and 2 patients with anterior cruciate ligament tear. The sensitivity, specificity and accuracy in diagnosis of posterior lateral meniscus root tears for doctor A were 73.7%, 79.9% and 79% respectively, and for doctor B were 78.9%, 82.3% and 82.5%, 4 patients with lateral meniscus herniation and 16 patients with cruciate ligament tear. Kappa statistics for posterior medial meniscus root tears and posterior lateral meniscus root tears were 0.84 and 0.72. MRI could effectively demonstrate imaging features of medial and lateral meniscal root tear and its accompanying signs. It could provide the basis for preoperative diagnosis of clinicians, and be worthy to be popularized. Copyright© 2018 by the China Journal of Orthopaedics and Traumatology Press.

  2. Methods to enhance seismic faults and construct fault surfaces

    NASA Astrophysics Data System (ADS)

    Wu, Xinming; Zhu, Zhihui

    2017-10-01

    Faults are often apparent as reflector discontinuities in a seismic volume. Numerous types of fault attributes have been proposed to highlight fault positions from a seismic volume by measuring reflection discontinuities. These attribute volumes, however, can be sensitive to noise and stratigraphic features that are also apparent as discontinuities in a seismic volume. We propose a matched filtering method to enhance a precomputed fault attribute volume, and simultaneously estimate fault strikes and dips. In this method, a set of efficient 2D exponential filters, oriented by all possible combinations of strike and dip angles, are applied to the input attribute volume to find the maximum filtering responses at all samples in the volume. These maximum filtering responses are recorded to obtain the enhanced fault attribute volume while the corresponding strike and dip angles, that yield the maximum filtering responses, are recoded to obtain volumes of fault strikes and dips. By doing this, we assume that a fault surface is locally planar, and a 2D smoothing filter will yield a maximum response if the smoothing plane coincides with a local fault plane. With the enhanced fault attribute volume and the estimated fault strike and dip volumes, we then compute oriented fault samples on the ridges of the enhanced fault attribute volume, and each sample is oriented by the estimated fault strike and dip. Fault surfaces can be constructed by directly linking the oriented fault samples with consistent fault strikes and dips. For complicated cases with missing fault samples and noisy samples, we further propose to use a perceptual grouping method to infer fault surfaces that reasonably fit the positions and orientations of the fault samples. We apply these methods to 3D synthetic and real examples and successfully extract multiple intersecting fault surfaces and complete fault surfaces without holes.

  3. Abnormal fault-recovery characteristics of the fault-tolerant multiprocessor uncovered using a new fault-injection methodology

    NASA Technical Reports Server (NTRS)

    Padilla, Peter A.

    1991-01-01

    An investigation was made in AIRLAB of the fault handling performance of the Fault Tolerant MultiProcessor (FTMP). Fault handling errors detected during fault injection experiments were characterized. In these fault injection experiments, the FTMP disabled a working unit instead of the faulted unit once in every 500 faults, on the average. System design weaknesses allow active faults to exercise a part of the fault management software that handles Byzantine or lying faults. Byzantine faults behave such that the faulted unit points to a working unit as the source of errors. The design's problems involve: (1) the design and interface between the simplex error detection hardware and the error processing software, (2) the functional capabilities of the FTMP system bus, and (3) the communication requirements of a multiprocessor architecture. These weak areas in the FTMP's design increase the probability that, for any hardware fault, a good line replacement unit (LRU) is mistakenly disabled by the fault management software.

  4. Relationship of Tear Size and Location to Fatty Degeneration of the Rotator Cuff

    PubMed Central

    Kim, H. Mike; Dahiya, Nirvikar; Teefey, Sharlene A.; Keener, Jay D.; Galatz, Leesa M.; Yamaguchi, Ken

    2010-01-01

    Background: Fatty degeneration of the rotator cuff muscles may have detrimental effects on both anatomical and functional outcomes following shoulder surgery. The purpose of this study was to investigate the relationship between tear geometry and muscle fatty degeneration in shoulders with a deficient rotator cuff. Methods: Ultrasonograms of both shoulders of 262 patients were reviewed to assess the type of rotator cuff tear and fatty degeneration in the supraspinatus and infraspinatus muscles. The 251 shoulders with a full-thickness tear underwent further evaluation for tear size and location. The relationship of tear size and location to fatty degeneration of the supraspinatus and infraspinatus muscles was investigated with use of statistical comparisons and regression models. Results: Fatty degeneration was found almost exclusively in shoulders with a full-thickness rotator cuff tear. Of the 251 shoulders with a full-thickness tear, eighty-seven (34.7%) had fatty degeneration in either the supraspinatus or infraspinatus, or both. Eighty-two (32.7%) of the 251 full-thickness tears had a distance of 0 mm between the biceps tendon and anterior margin of the tear. Ninety percent of the full-thickness tears with fatty degeneration in both muscles had a distance of 0 mm posterior from the biceps, whereas only 9% of those without fatty degeneration had a distance of 0 mm. Tears with fatty degeneration had significantly greater width and length than those without fatty degeneration (p < 0.0001). Tears with fatty degeneration had a significantly shorter distance posterior from the biceps than those without fatty degeneration (p < 0.0001). The distance posterior from the biceps was found to be the most important predictor for supraspinatus fatty degeneration, whereas tear width and length were found to be the most important predictors for infraspinatus fatty degeneration. Conclusions: Fatty degeneration of the rotator cuff muscles is closely associated with tear size and

  5. Full-thickness tears of the supraspinatus tendon: A three-dimensional finite element analysis.

    PubMed

    Quental, C; Folgado, J; Monteiro, J; Sarmento, M

    2016-12-08

    Knowledge regarding the likelihood of propagation of supraspinatus tears is important to allow an early identification of patients for whom a conservative treatment is more likely to fail, and consequently, to improve their clinical outcome. The aim of this study was to investigate the potential for propagation of posterior, central, and anterior full-thickness tears of different sizes using the finite element method. A three-dimensional finite element model of the supraspinatus tendon was generated from the Visible Human Project data. The mechanical behaviour of the tendon was fitted from experimental data using a transversely isotropic hyperelastic constitutive model. The full-thickness tears were simulated at the supraspinatus tendon insertion by decreasing the interface area. Tear sizes from 10% to 90%, in 10% increments, of the anteroposterior length of the supraspinatus footprint were considered in the posterior, central, and anterior regions of the tendon. For each tear, three finite element analyses were performed for a supraspinatus force of 100N, 200N, and 400N. Considering a correlation between tendon strain and the risk of tear propagation, the simulated tears were compared qualitatively and quantitatively by evaluating the volume of tendon for which a maximum strain criterion was not satisfied. The finite element analyses showed a significant impact of tear size and location not only on the magnitude, but also on the patterns of the maximum principal strains. The mechanical outcome of the anterior full-thickness tears was consistently, and significantly, more severe than that of the central or posterior full-thickness tears, which suggests that the anterior tears are at greater risk of propagating than the central or posterior tears. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Evidence of displacement-driven maturation along the San Cristobal Trough transform plate boundary

    NASA Astrophysics Data System (ADS)

    Neely, James S.; Furlong, Kevin P.

    2018-03-01

    The San Cristobal Trough (SCT), formed by the tearing of the Australia plate as it subducts under the Pacific plate near the Solomon Islands, provides an opportunity to study the transform boundary development process. Recent seismicity (2013-2016) along the 280 km long SCT, known as a Subduction-Transform Edge Propagator (STEP) fault, highlights the tearing process and ongoing development of the plate boundary. The region's earthquakes reveal two key characteristics. First, earthquakes at the western terminus of the SCT, which we interpret to indicate the Australia plate tearing, display disparate fault geometries. These events demonstrate that plate tearing is accommodated via multiple intersecting planes rather than a single through-going fault. Second, the SCT hosts sequences of Mw ∼7 strike-slip earthquakes that migrate westward through a rapid succession of events. Sequences in 1993 and 2015 both began along the eastern SCT and propagated west, but neither progression ruptured into or nucleated a large earthquake within the region near the tear. Utilizing b-value and Coulomb Failure Stress analyses, we examine these along-strike variations in the SCT's seismicity. b-Values are highest along the youngest, western end of the SCT and decrease with increasing distance from the tear. This trend may reflect increasing strain localization with increasing displacement. Coulomb Failure Stress analyses indicate that the stress conditions were conducive to continued western propagation of the 1993 and 2015 sequences suggesting that the unruptured western SCT may have fault geometries or properties that inhibit continued rupture. Our results indicate a displacement-driven fault maturation process. The multi-plane Australia plate tearing likely creates a western SCT with diffuse strain accommodated along a network of disorganized faults. After ∼90 km of cumulative displacement (∼900,000 yr of plate motion), strain localizes and faults align, allowing the SCT to host

  7. Stabilizing effect of helical current drive on tearing modes

    NASA Astrophysics Data System (ADS)

    Yuan, Y.; Lu, X. Q.; Dong, J. Q.; Gong, X. Y.; Zhang, R. B.

    2018-01-01

    The effect of helical driven current on the m = 2/n = 1 tearing mode is studied numerically in a cylindrical geometry using the method of reduced magneto-hydro-dynamic simulation. The results show that the local persistent helical current drive from the beginning time can be applied to control the tearing modes, and will cause a rebound effect called flip instability when the driven current reaches a certain value. The current intensity threshold value for the occurrence of flip instability is about 0.00087I0. The method of controlling the development of tearing mode with comparative economy is given. If the local helical driven current is discontinuous, the magnetic island can be controlled within a certain range, and then, the tearing modes stop growing; thus, the flip instability can be avoided. We also find that the flip instability will become impatient with delay injection of the driven current because the high order harmonics have been developed in the original O-point. The tearing mode instability can be controlled by using the electron cyclotron current drive to reduce the gradient of the current intensity on the rational surfaces.

  8. Superior Labrum Anterior-Posterior Tears in the National Football League.

    PubMed

    Chambers, Caitlin C; Lynch, T Sean; Gibbs, Daniel B; Ghodasra, Jason H; Sahota, Shawn; Franke, Kristina; Mack, Christina D; Nuber, Gordon W

    2017-01-01

    Shoulder disorders are common in football players, with up to 50% of National Football League (NFL) recruits reporting a history of shoulder injuries. Superior labrum anterior-posterior (SLAP) tears are an entity with well-described detrimental effects on return to play in overhead-throwing athletes but with minimal data in contact athletes. To identify the incidence, predisposing factors, and effect of SLAP tears in NFL athletes and prospects as well as the treatment patterns of NFL team physicians. Descriptive epidemiology study. This study was a comprehensive analysis of SLAP tears in elite football players using a dual approach: (1) SLAP injuries recorded in the NFL Injury Surveillance System from 2000 to 2014 were evaluated by player position, type of play, days/games lost, and surgical intervention; (2) NFL Scouting Combine athletes from 2003 to 2011 with prior SLAP repair were evaluated for draft success, and drafted athletes were compared with matched controls for career length and performance scores. SLAP tears represented a small portion (3.1%) of shoulder injuries in NFL athletes from 2000 to 2014, occurring most commonly in offensive linemen (28%). Surgically treated SLAP tears (42%) resulted in more days missed than did nonoperatively managed tears (140.2 vs 21.5 days; P < .001) and more games missed (8.4 vs 2.6 games; P = .003). SLAP repairs were also rare in NFL Combine athletes (n = 25 of 2965 athletes), with most having been performed in offensive linemen (32%). As compared with control NFL Combine athletes without SLAP tears, those drafted into the NFL with prior SLAP repair played significantly fewer games (33.7 vs 48.3; P = .049) and had fewer game starts (19.6 vs 35.4; P = .036). In this comprehensive analysis of SLAP tears in elite football players, it is clear that these injuries have the potential to cause significant detriment to an athlete's career.

  9. Cytokine changes in tears and relationship to contact lens discomfort.

    PubMed

    Willcox, Mark D P; Zhao, Zhenjun; Naduvilath, Thomas; Lazon de la Jara, Percy

    2015-01-01

    To determine the reproducibility of a multiplex bead assay for measuring cytokines in tears and correlations between ocular discomfort with or without contact lens wear and the concentration of cytokines in tears. Ninety participants (divided into two groups) were enrolled in this prospective study. They were asked to rate their ocular comfort and collect their tears in the morning and just before sleep for 10 days with or without contact lenses. The participants collected their tears using a glass microcapillary tube for both stages. Galyfilcon A lenses were worn on a daily disposable basis during the contact lens stage, and comfort scores and tears were collected before lens insertion and prior to lens removal at the end of the day. Tears were analyzed for cytokine concentrations using a 27-plex multibead assay. Correlations were sought between cytokine concentrations and comfort. There was a significant (p<0.022) decrease in ocular comfort over the day with or without lens wear. The magnitude of ocular discomfort was significantly greater (p<0.009) with lens wear. The concentrations of 12 cytokines differed significantly between the groups; thus, these cytokines were not analyzed further. For the remaining 15 cytokines, interleukin-8 (IL-8) was the only cytokine that changed in both groups during the day without (reduced by >-0.5 Log pg/ml, p<0.001) or with lens wear (reduced by >-0.2 Log pg/ml, p<0.001). The change in the vascular endothelial growth factor (VEGF) concentration only in tears was correlated to ocular comfort, but this was not changed by contact lens wear. Ocular comfort during the day is magnified by contact lens wear. However, the increase in the change in comfort during lens wear was not associated with changes in 15 cytokines in the tear film.

  10. Cytokine changes in tears and relationship to contact lens discomfort

    PubMed Central

    Zhao, Zhenjun; Naduvilath, Thomas; Lazon de la Jara, Percy

    2015-01-01

    Purpose To determine the reproducibility of a multiplex bead assay for measuring cytokines in tears and correlations between ocular discomfort with or without contact lens wear and the concentration of cytokines in tears. Methods Ninety participants (divided into two groups) were enrolled in this prospective study. They were asked to rate their ocular comfort and collect their tears in the morning and just before sleep for 10 days with or without contact lenses. The participants collected their tears using a glass microcapillary tube for both stages. Galyfilcon A lenses were worn on a daily disposable basis during the contact lens stage, and comfort scores and tears were collected before lens insertion and prior to lens removal at the end of the day. Tears were analyzed for cytokine concentrations using a 27-plex multibead assay. Correlations were sought between cytokine concentrations and comfort. Results There was a significant (p<0.022) decrease in ocular comfort over the day with or without lens wear. The magnitude of ocular discomfort was significantly greater (p<0.009) with lens wear. The concentrations of 12 cytokines differed significantly between the groups; thus, these cytokines were not analyzed further. For the remaining 15 cytokines, interleukin-8 (IL-8) was the only cytokine that changed in both groups during the day without (reduced by >-0.5 Log pg/ml, p<0.001) or with lens wear (reduced by >-0.2 Log pg/ml, p<0.001). The change in the vascular endothelial growth factor (VEGF) concentration only in tears was correlated to ocular comfort, but this was not changed by contact lens wear. Conclusions Ocular comfort during the day is magnified by contact lens wear. However, the increase in the change in comfort during lens wear was not associated with changes in 15 cytokines in the tear film. PMID:25814827

  11. Tearing Instability of a Current Sheet Forming by Sheared Incompressible Flow

    NASA Astrophysics Data System (ADS)

    Tolman, Elizabeth; Loureiro, Nuno; Uzdensky, Dmitri

    2017-10-01

    Sweet-Parker current sheets are unstable to the tearing mode, suggesting they will not form in physical systems. Understanding magnetic reconnection thus requires study of the stability of a current sheet as it forms. Such formation can occur as a result of sheared, sub-Alfvénic incompressible flows into and along the sheet. This work presents an analysis of how tearing perturbations behave in a current sheet forming under the influence of such flows, beginning with a phase when the growth rate of the tearing mode is small and the behavior of perturbations is primarily governed by ideal MHD. Later, after the tearing growth rate becomes significant relative to the time scale of the driving flows, the flows cause a slight reduction in the tearing growth rate and wave vector of the dominant mode. Once the tearing mode enters the nonlinear regime, the flows accelerate the tearing growth slightly; during X-point collapse, the flows have negligible effect on the system behavior. This analysis allows greater understanding of reconnection in evolving systems and increases confidence in the application of tools developed in time-independent current sheets to changing current sheets. This material is based upon work supported by the National Science Foundation Graduate Research Fellowship.

  12. Potential of FTIR spectroscopy for analysis of tears for diagnosis purposes.

    PubMed

    Travo, Adrian; Paya, Clément; Déléris, Gérard; Colin, Joseph; Mortemousque, Bruno; Forfar, Isabelle

    2014-04-01

    It has been widely reported that the tear film, which is crucially important as a protective barrier of the eye, undergoes biochemical changes as a result of a wide range of ocular pathology. This tends to suggest the possibility of early detection of ocular diseases on the basis of biochemical analysis of tears. However, studies of tears by conventional methods of biomolecular and biochemical analysis are often limited by methodological difficulties. Moreover, such analysis could not be applied in the clinic, where structural and morphological analyses by, mainly, slit-lamp biomicroscopy remains the recommended method. In this study, we assessed, for the first time, the potential of FTIR spectroscopy combined with advanced chemometric processing of spectral data for analysis of raw tears for diagnosis purposes. We first optimized sampling and spectral acquisition (tears collection method, tear sample volume, and preservation of the samples) for accurate spectral measurement. On the basis of the results, we focused our study on the possibility of discriminating tears from normal individuals from those of patients with different ocular pathologies, and showed that the most discriminating spectral range is that corresponding to variations of CH2 and CH3 of lipid aliphatic chains. We also report more subtle discrimination of tears from patients with keratoconus and those from patients with non-specific inflammatory ocular diseases, on the basis of variations in spectral ranges attributed notably to lipid and carbohydrate vibrations. Finally, we also succeeded in distinguishing tears from patients with early-stage and late-stage keratoconus on the basis of spectral features attributed to protein structure. Therefore, this study strongly suggests that FTIR spectral analysis of tears could be developed as a valuable and cost-saving tool for biochemical-based detection of ocular diseases, potentially before the appearance of the first morphological signs of diseases

  13. Multiscale Dynamics of Aseismic Slip on Central San Andreas Fault

    NASA Astrophysics Data System (ADS)

    Khoshmanesh, M.; Shirzaei, M.

    2018-03-01

    Understanding the evolution of aseismic slip enables constraining the fault's seismic budget and provides insight into dynamics of creep. Inverting the time series of surface deformation measured along the Central San Andreas Fault obtained from interferometric synthetic aperture radar in combination with measurements of repeating earthquakes, we constrain the spatiotemporal distribution of creep during 1992-2010. We identify a new class of intermediate-term creep rate variations that evolve over decadal scale, releasing stress on the accelerating zone and loading adjacent decelerating patches. We further show that in short-term (<2 year period), creep avalanches, that is, isolated clusters of accelerated aseismic slip with velocities exceeding the long-term rate, govern the dynamics of creep. The statistical properties of these avalanches suggest existence of elevated pore pressure in the fault zone, consistent with laboratory experiments.

  14. Bone mineralization changes of the glenoid in shoulders with symptomatic rotator cuff tear.

    PubMed

    Harada, Yohei; Yokoya, Shin; Akiyama, Yuji; Mochizuki, Yu; Ochi, Mitsuo; Adachi, Nobuo

    2018-06-06

    Computed tomography osteoabsorptiometry (CTO) is a method to analyze the stress distribution in joints by measuring the subchondral bone density. The purpose of this study was to evaluate the bone mineralization changes of the glenoid in shoulders with rotator cuff tears by CTO and to evaluate whether rotator cuff tears are associated with stress changes in the glenoid. In total, 32 patients, who were diagnosed with unilateral rotator cuff tears and underwent arthroscopic rotator cuff repair, were enrolled in this study. They underwent CT scanning of both shoulders pre-operatively and the glenoid was evaluated using CTO. Hounsfield units (HU) in seven areas of the glenoid were compared between the affected and unaffected sides. The central area of the glenoid on the affected side had significantly lower HU than on the unaffected side among all patients. Focusing on the rotator cuff tear size and the subscapularis tendon, only patients with larger cuff tears or with subscapularis tendon tears showed significantly lower HU in the central area of the affected side. This study showed a decrease in bone mineralization density in the central glenoid in shoulders with rotator cuff tear. This change was observed in the case of larger cuff tears and subscapularis tendon tears. Our results help clarify the changes in stress distribution in the shoulder joint caused by symptomatic rotator cuff tears.

  15. Partial supraspinatus tears are associated with tendon lengthening.

    PubMed

    Farshad-Amacker, Nadja A; Buck, Florian M; Farshad, Mazda; Pfirrmann, Christian W A; Gerber, Christian

    2015-02-01

    Tendon tear may result in muscular retraction with the loss of contractile amplitude and strength of the rotator cuff muscles. Currently, neither a validated method of measuring supraspinatus tendon length nor normal values are known. It was therefore the purpose of this study to measure the normal length of the supraspinatus tendon and to determine whether partial tears are associated with changes in tendon length. MR examinations of 49 asymptomatic volunteers and 37 patients with arthroscopically proven, isolated partial tears of the supraspinatus tendon were compared. The ratio of the extramuscular tendon length to the distance between the footprint and the glenoid surface was calculated (TL/FG ratio). Tendon length measurements were taken by two independent readers at the bursal and articular surfaces at the anterior, the central and the posterior parts of the tendon. TL/FG ratios at the bursal surface of tendons with partial tears were significantly higher than those in the control group [anterior: 0.78 ± 0.20 vs. 0.66 ± 0.15 (p < 0.05); central: 0.61 ± 0.13 vs. 0.52 ± 0.10 (p < 0.05); posterior: 0.57 ± 0.15 vs. 0.52 ± 0.10 (p < 0.05)]. At the articular surface, differences were significant only anteriorly [0.60 ± 0.13, vs. 0.54 ± 0.10 (p < 0.05)]. A cut-off TL/FG ratio of 0.63 for measurements at the bursal surface in the center of the tendon achieved a sensitivity of 46 % and a specificity of 92 % for the identification of partial cuff tearing. A reproducible method for measurement of extramuscular supraspinatus tendon length is described. Partial tearing of the supraspinatus tendon is associated with significant tendon lengthening, suggesting failure in continuity, and this is most reliably measured on the bursal surface. III.

  16. Symptoms, visual function, and mucin expression of eyes with tear film instability.

    PubMed

    Shimazaki-Den, Seika; Dogru, Murat; Higa, Kazunari; Shimazaki, Jun

    2013-09-01

    We examined symptoms, tear stability, visual function, and conjunctival cytology in eyes with an unstable tear film (UTF), expressed as a short tear film breakup time without epithelial damage or low tear secretion, and compared the results with those from eyes with aqueous deficiency (AD) associated with epithelial damage, and healthy eyes. We divided the patients with ocular discomfort into 2 groups according to the breakup time, Schirmer value, and epithelial staining score: UTF group (≤5 seconds, >5 mm, and <3 points; 21 eyes of 21 patients) and AD group (≤5 seconds, ≤5 mm, and ≥3 points; 21 eyes of 21 patients). We examined all patients and 17 healthy subjects for symptoms, tear functions, tear film stability by tear film lipid layer interferometry and tear film analysis system, and functional visual acuity. Conjunctival impression cytology was performed to investigate changes in goblet cell density, squamous metaplasia, and messenger RNA expression of MUC5AC and MUC16. The symptom scores, tear film analysis system index, and functional visual acuity testing were significantly worse in the UTF and AD groups compared with those in the control group (P < 0.05). The messenger RNA expression levels of MUC5AC and MUC16 were significantly lower in UTF and AD eyes compared with those in the control eyes (P < 0.0001). An UTF itself can cause dry eye symptoms and visual disturbance comparable with those of AD dry eyes.

  17. Effect of topical ophthalmic epinastine and olopatadine on tear volume in mice.

    PubMed

    Villareal, Arturo L; Farley, William; Pflugfelder, Stephen C

    2006-12-01

    To investigate the effects of topical epinastine and olopatadine on tear volume by using a mouse model. Eighty-five C57BL6 mice (170 eyes) were treated twice daily with topical ophthalmic epinastine 0.05%, olopatadine 0.1%, or atropine 1% or served as untreated controls. A thread-wetting assay was used to measure tear volume at baseline and 15, 45, 90, 120, and 240 minutes after the last instillation of the drug on days 2 and 4 of treatment. After 2 days of treatment, epinastine-treated mice showed greater mean tear volumes than olopatadine-treated mice did at 15, 45, 90, and 240 minutes, with statistical significance at 15 and 45 minutes (P<0.001). Olopatadine significantly reduced tear volume versus untreated controls at 15 and 45 minutes (P<0.001). After 4 days, tear volumes with epinastine treatment exceeded those with olopatadine treatment at all time points, with statistical significance at 45 minutes (P<0.05). Atropine rendered tears undetectable at 15, 45, and 90 minutes; tear volume returned to baseline levels at 240 minutes. Topical epinastine did not inhibit tear secretion, whereas olopatadine caused a significant decrease in tear volume. Because of its neutral impact on the lacrimal functional unit, epinastine may be an especially good choice for the treatment of allergic conjunctivitis in patients with dry eye disease or in those who are at risk for developing dry eye.

  18. The Location of Anterior Cruciate Ligament Tears: A Prevalence Study Using Magnetic Resonance Imaging

    PubMed Central

    van der List, Jelle P.; Mintz, Douglas N.; DiFelice, Gregory S.

    2017-01-01

    Background: Over the past decade, there has been a resurgence of interest in anterior cruciate ligament (ACL) preservation. Proximal and distal avulsion tears have been treated with arthroscopic primary repair, while augmented repair, remnant tensioning, primary repair with biological scaffold, and remnant preservation have been proposed for different types of midsubstance tears. Currently, the incidence of these different tear types is unknown. Purpose: To propose a magnetic resonance imaging (MRI) classification system for different tear types based on clinical relevance and to assess the distribution of these different ACL tear types. Study Design: Case series; Level of evidence, 4. Methods: A retrospective search in an institutional radiographic database was performed for patients who underwent knee MRI at our institution between June 2014 and June 2016. Patients younger than 18 years and those with reports of chronic tears, partial tears, multiligamentous injuries, were excluded. Tear types were graded as proximal avulsion (distal remnant length >90% of total ligament length, type I), proximal (75%-90%, type II), midsubstance (25%-75%, type III), distal (10%-25%, type IV), and distal avulsion (<10%, type V). An orthopaedic surgeon, a radiologist, and a research fellow graded the tear type on 30 MRIs to determine reliability, and the research fellow graded all MRIs. Inter- and intraobserver reliability were measured using kappa statistics. Results: A total of 353 patients (57% male; mean age, 37.1 years; range, 18.1-81.2 years) were included. Interobserver reliability was 0.670 (95% confidence interval, 0.505-0.836), and intraobserver reliability ranged from 0.741 to 0.934. Incidence of type I tears was 16%, type II tears 27%, type III tears 52%, type IV tears 1%, and type V tears 3% (2.5% with bony avulsion). Type I tears were more common in patients older than 35 years compared with those younger than 35 years (23% vs 8%; P < .001). Conclusion: This

  19. Tear Film Lipids

    PubMed Central

    Butovich, Igor A.

    2013-01-01

    Human meibomian gland secretions (MGS, or meibum) are formed from a complex mixture of lipids of different classes such as wax esters, cholesteryl esters, (O-acyl)-ω-hydroxy fatty acids (OAHFA) and their esters, acylglycerols, diacylated diols, free fatty acids, cholesterol, and a smaller amount of other polar and nonpolar lipids, whose chemical nature and the very presence in MGS have been a matter of intense debates. The purpose of this review is to discuss recent results that were obtained using different experimental techniques, estimate limitations of their usability, and discuss their biochemical, biophysical, and physiological implications. To create a lipid map of MGS and tears, the results obtained in the author’s laboratory were integrated with available information on chemical composition of MGS and tears. The most informative approaches that are available today to researchers, such as HPLC-MS, GC-MS, and proton NMR, are discussed in details. A map of the meibomian lipidome (as it is seen in reverse phase liquid chromatography/mass spectrometry experiments) is presented. Directions of future efforts in the area are outlined. PMID:23769846

  20. Wide-angle seismic data from the East Sicily margin: Imaging the deep structure of a Tethyan transform margin and the modern Calabria subduction lateral slab tear.

    NASA Astrophysics Data System (ADS)

    Dellong, D.; Klingelhoefer, F.; Kopp, H.; Gutscher, M. A.

    2016-12-01

    It is generally accepted that a STEP fault (Subduction Tear Edge Propagator) has accommodated the roll back of the Ionian Slab along the eastern Sicily Margin since 6 to 7 Ma. However the location of this lithospheric scale tear fault, and its surface expression is controversial. Constrain by numerous bathymetric imaging and shallow sub-surface multi-channels seismic (MCS) studies, variety of fault geometry was proposed. Moreover the role of the Malta Escarpment in this geodynamic system also remain the object of debates. It may be linked to the opening of the Ionian basin during a phase of strike-slip rifting since more than 180 Ma. Here we present the results of modelling of two wide-angle seismic profiles from the DIONYSUS survey (R/V Meteor, Oct. 2014). The first profile (DY-P3) was recorded by 25 Ocean- Bottom-Seismometers (OBS) and 3 land stations, and the second profile (DY-P1) by 52 OBS. Forward modelling of both profiles reveals a zone of abrupt crustal thinning from about 30 km below the Hyblean plateau and East-Sicily continental domain, to values of 8-15 km over a short lateral distance of 20-30 km. In the northern profile (DY-P3) the crust east of this abrupt thinning is of transitional thickness (15 km) and characterized by seismic velocities and velocity gradients similar to thinned continental crust. In the southern profile (DY-P1) this crust is 6-8 km thick, and the velocity gradients are close to those of oceanic crust. On this profile about 50-60 km eastward from the base of the Malta Escarpment, a lateral change of crustal velocities was modelled. Here a recent shallow transtensional deformation has been observed in MCS data at the position of this structure and linked to an elongated basin visible in the bathymetry and was linked to the STEP fault location. The results of the wide-angle seismic modelling suggest an ancient origin for the Malta Escarpment, formed as a transform margin during opening of the Ionian Basin about 180 Ma ago. The

  1. Crustal-Scale Fault Interaction at Rifted Margins and the Formation of Domain-Bounding Breakaway Complexes: Insights From Offshore Norway

    NASA Astrophysics Data System (ADS)

    Osmundsen, P. T.; Péron-Pinvidic, G.

    2018-03-01

    The large-magnitude faults that control crustal thinning and excision at rifted margins combine into laterally persistent structural boundaries that separate margin domains of contrasting morphology and structure. We term them breakaway complexes. At the Mid-Norwegian margin, we identify five principal breakaway complexes that separate the proximal, necking, distal, and outer margin domains. Downdip and lateral interactions between the faults that constitute breakaway complexes became fundamental to the evolution of the 3-D margin architecture. Different types of fault interaction are observed along and between these faults, but simple models for fault growth will not fully describe their evolution. These structures operate on the crustal scale, cut large thicknesses of heterogeneously layered lithosphere, and facilitate fundamental margin processes such as deformation coupling and exhumation. Variations in large-magnitude fault geometry, erosional footwall incision, and subsequent differential subsidence along the main breakaway complexes likely record the variable efficiency of these processes.

  2. Kinematics of polygonal fault systems: observations from the northern North Sea

    NASA Astrophysics Data System (ADS)

    Wrona, Thilo; Magee, Craig; Jackson, Christopher A.-L.; Huuse, Mads; Taylor, Kevin G.

    2017-12-01

    Layer-bound, low-displacement normal faults, arranged into a broadly polygonal pattern, are common in many sedimentary basins. Despite having constrained their gross geometry, we have a relatively poor understanding of the processes controlling the nucleation and growth (i.e. the kinematics) of polygonal fault systems. In this study we use high-resolution 3-D seismic reflection and borehole data from the northern North Sea to undertake a detailed kinematic analysis of faults forming part of a seismically well-imaged polygonal fault system hosted within the up to 1000 m thick, Early Palaeocene-to-Middle Miocene mudstones of the Hordaland Group. Growth strata and displacement-depth profiles indicate faulting commenced during the Eocene to early Oligocene, with reactivation possibly occurring in the late Oligocene to middle Miocene. Mapping the position of displacement maxima on 137 polygonal faults suggests that the majority (64%) nucleated in the lower 500 m of the Hordaland Group. The uniform distribution of polygonal fault strikes in the area indicates that nucleation and growth were not driven by gravity or far-field tectonic extension as has previously been suggested. Instead, fault growth was likely facilitated by low coefficients of residual friction on existing slip surfaces, and probably involved significant layer-parallel contraction (strains of 0.01-0.19) of the host strata. To summarize, our kinematic analysis provides new insights into the spatial and temporal evolution of polygonal fault systems.

  3. Emotional tears facilitate the recognition of sadness and the perceived need for social support.

    PubMed

    Balsters, Martijn J H; Krahmer, Emiel J; Swerts, Marc G J; Vingerhoets, Ad J J M

    2013-02-12

    The tearing effect refers to the relevance of tears as an important visual cue adding meaning to human facial expression. However, little is known about how people process these visual cues and their mediating role in terms of emotion perception and person judgment. We therefore conducted two experiments in which we measured the influence of tears on the identification of sadness and the perceived need for social support at an early perceptional level. In two experiments (1 and 2), participants were exposed to sad and neutral faces. In both experiments, the face stimuli were presented for 50 milliseconds. In experiment 1, tears were digitally added to sad faces in one condition. Participants demonstrated a significant faster recognition of sad faces with tears compared to those without tears. In experiment 2, tears were added to neutral faces as well. Participants had to indicate to what extent the displayed individuals were in need of social support. Study participants reported a greater perceived need for social support to both sad and neutral faces with tears than to those without tears. This study thus demonstrated that emotional tears serve as important visual cues at an early (pre-attentive) level.

  4. A Disposable Tear Glucose Biosensor—Part 1: Design and Concept Testing

    PubMed Central

    Bishop, Daniel K.; La Belle, Jeffrey T.; Vossler, Stephen R.; Patel, Dharmendra R.; Cook, Curtiss B.

    2010-01-01

    Background Tear glucose has been suggested previously as a potential approach for the noninvasive estimation of blood glucose. While the topic remains unresolved, an overview of previous studies suggests the importance of a tear sampling approach and warrants new technology development. A concept device is presented that meets the needs of a tear glucose biosensor. Methods Three approaches to chronoamperometric glucose sensing were evaluated, including glucose oxidase mediated by potassium ferricyanide or oxygen with a hydrogen peroxide catalyst, Prussian blue, and potassium ferricyanide-mediated glucose dehydrogenase. For tear sampling, calcium alginate, poly(2-hydroxyethyl methacrylate), and polyurethane foam were screened as an absorbent tear sampling material. A quantitative model based on the proposed function of concept device was created. Results For glucose sensing, it was found that potassium ferricyanide with glucose dehydrogenase was ideal, featuring oxygen insensitivity, long-term stability, and a lower limit of detection of 2 μM glucose. Polyurethane foam possessed all of the required characteristics for tear sampling, including reproducible sampling from a hydrogel-simulated, eye surface (4.2 ± 0.5 μl; n = 8). It is estimated that 100 μM of glucose tear fluid would yield 135 nA (14.9% relative standard deviation). Conclusion A novel concept device for tear glucose sampling was presented, and the key functions of this device were tested and used to model the performance of the final device. Based on these promising initial results, the device is achievable and within reach of current technical capabilities, setting the stage for prototype development. PMID:20307389

  5. Tears of Wine

    ERIC Educational Resources Information Center

    Gugliotti, Marcos

    2004-01-01

    The unique occurrence of the upward motion of a thin film of wine, and its formation into drops inside the wall of a wine glass is explained. Evaporation of alcohol generates a surface tension gradient, moving the film of wine upwards on the internal sides of a wine glass, where it collects and forms into drops or tears.

  6. Postanaesthetic tear production and ocular irritation in cats.

    PubMed

    Peche, N; Köstlin, R; Reese, S; Pieper, K

    2015-01-01

    General anaesthesia significantly reduces tear production and normal values are not immediately re-established on ending anaesthesia. Therefore, adequate protection of the cornea has to be assured during the perianaesthetic period. There are various methods available, including taping of the eyelids and the application of eye ointments, gels and drops. In human medicine studies, different formulations were found to induce signs of ocular irritation. The aim of the present study was to determine tear production in cats after general anaesthesia, and to identify possible causes of irritation. Tear production was determined in 41 cats after general anaesthesia and eyes were examined for signs of irritation. Two different anaesthetic protocols were used. To protect the cornea, an ointment and gel were applied to the right and left eyes, respectively. Postoperatively, tear production was significantly reduced for 6 hours and 18 hours in the right and left eyes, respectively. Two hours after anaesthesia, blepharospasm of the right eye was observed in 92.7% (n = 38) of the cats. In contrast, the left eye was always held open. This study demonstrated that tear production in cats is significantly decreased both during and after anaesthesia. The degree of reduction was independent of the anaesthetic protocol. Both the eye ointment and gel proved effective in protecting the corneal surface. However, eye gel use is recommended because the eye ointment consistently caused an irritation comparable to the foreign-body sensation reported in humans.

  7. Susceptibility of experimental faults to pore pressure increase: insights from load-controlled experiments on calcite-bearing rocks

    NASA Astrophysics Data System (ADS)

    Spagnuolo, Elena; Violay, Marie; Nielsen, Stefan; Cornelio, Chiara; Di Toro, Giulio

    2017-04-01

    Fluid pressure has been indicated as a major factor controlling natural (e.g., L'Aquila, Italy, 2009 Mw 6.3) and induced seismicity (e.g., Wilzetta, Oklahoma, 2011 Mw 5.7). Terzaghi's principle states that the effective normal stress is linearly reduced by a pore pressure (Pf) increase σeff=σn(1 - αPf), where the effective stress parameter α, may be related to the fraction of the fault area that is flooded. A value of α =1 is often used by default, with Pf shifting the Mohr circle towards lower normal effective stresses and anticipating failure on pre-existing faults. However, within a complex fault core of inhomogeneous permeability, α may vary in a yet poorly understood way. To shed light on this problem, we conducted experiments on calcite-bearing rock samples (Carrara marble) at room humidity conditions and in the presence of pore fluids (drained conditions) using a rotary apparatus (SHIVA). A pre-cut fault is loaded by constant shear stress τ under constant normal stress σn=15 MPa until a target value corresponding roughly to the 80 % of the frictional fault strength. The pore pressure Pf is then raised with regular pressure and time steps to induce fault instability. Assuming α=1 and a threshold for instability τp_eff=μp σeff, the experiments reveal that an increase of Pf does not necessarily induce an instability even when the effective strength threshold is largely surpassed (e.g., τp_eff=1.3 μpσeff). This result may indicate that the Pf increase did not instantly diffuse throughout the slip zone, but took a finite time to equilibrate with the external imposed pressure increase due to finite permeability. Under our experimental conditions, a significant departure from α=1 is observed provided that the Pf step is shorter than about < 20s. We interpret this delay as indicative of the diffusion time (td), which is related to fluid penetration length l by l = √ κtd-, where κ is the hydraulic diffusivity on the fault plane. We show that a

  8. Should massive rotator cuff tears be reconstructed even when only partially repairable?

    PubMed

    Godenèche, Arnaud; Freychet, Benjamin; Lanzetti, Riccardo Maria; Clechet, Julien; Carrillon, Yannick; Saffarini, Mo

    2017-07-01

    (1) To evaluate midterm functional outcomes of arthroscopic repair of massive rotator cuff tears and (2) to determine the prognostic factors that could influence outcome. The hypothesis was that both partial and complete repairs would result in equivalent improvement of clinical score. From a prospective series of 525 rotator cuff repairs, we analysed records of the 73 patients who were treated for massive tears. The median follow-up was 41 months (range 29-55), and functional outcome was evaluated using the Constant score, shoulder strength, and subjective shoulder value. The median CS improved from 34 points to 81 points (p < 0.001). The scores were better for both types of two-tendon tears, posterosuperior (83, n = 33) and anterosuperior (85, n = 13) (n.s.), than for three-tendon tears (74, n = 27) (p < 0.001). The scores were also better when fatty infiltration was of stage I (84, n = 28) than of stage II (78, n = 34) (p < 0.001) or stage III (74, n = 11) (p = 0.04). The scores were only slightly higher for completely reparable tears (81.5, n = 50) than for partially reparable tears (79, n = 23) (n.s.). Ultrasonic examination revealed incomplete healing, in 10 of the 50 completely repaired tears, and in 11 of the 23 partially repaired tears. The results of the present study compare favourably with those in recent literature and confirm the hypothesis that both partial and complete repairs of massive rotator cuff tears produce equivalent improvements of Constant scores. The clinical relevance of these observations is that even if repairs of two-tendon tears result in superior functional outcomes, repairs of three-tendon tears produce equivalent 'relative' improvement that grants sufficient patient satisfaction and autonomy. Comparative case series, Level IV.

  9. Human tear serotonin levels correlate with symptoms and signs of dry eye

    PubMed Central

    Chhadva, Priyanka; Lee, Tinthu; Sarantopoulos, Constantine D.; Hackam, Abigail S.; McClellan, Allison L.; Felix, Elizabeth R.; Levitt, Roy C.; Galor, Anat

    2015-01-01

    Purpose Serotonin, a neurotransmitter known to be involved in nociceptor sensitization, is present in human tears. The purpose of this study was to correlate tear serotonin levels, as a marker of nociceptor sensitization, to facets of dry eye (DE) including symptoms and signs. Design Cross-sectional study Participants Sixty-two patients with normal eyelid and corneal anatomy were prospectively recruited from a Veterans Administration Ophthalmology Clinic over 11 months. Methods DE symptoms (Ocular Surface Disease Index [OSDI]), signs (tear break-up time [TBUT], corneal staining, and Schirmer’s score), and clinical descriptors of neuropathic ocular pain (NOP) (sensitivity to light and/or sensitivity to wind) were assessed. For tear analysis, each patient’s tears were collected after instilling 50µl of sterile saline to the lower cul-de-sac of each eye and using capillary action microcaps to collect the ocular wash. Tear serotonin levels were measured using enzyme-linked immunosorbent assay. Main Outcomes Measured Correlations between tear serotonin concentrations and DE symptoms and signs. Results The mean age of the population was 61±14 years and 84% (n=52) of the patients were male. Serotonin concentrations negatively correlated with Schirmer’s scores (r=−0.28; p=0.02), but did not correlate with other DE parameters, such as OSDI scores, sensitivity to light or wind, TBUT, or staining. According to our hypothesis, we divided patients into groups based on both DE symptoms and aqueous tear production; serotonin concentrations were found to be significantly higher in DE group 1 (OSDI≥6 and Schirmer’s<8) compared to both DE group 2 (OSDI≥6 and Schirmer’s≥8) and controls (OSDI<6 and Schirmer’s≥8). Patients in the DE group 2 more frequently complained of sensitivity to light (64%) and wind (67%) compared to the DE group 1 (40% and 60%, respectively) and controls (8% and 17%, respectively). Conclusion Patients with DE symptoms and aqueous tear

  10. Evaluation of cartilage degeneration in a rat model of rotator cuff tear arthropathy

    PubMed Central

    Kramer, Erik J.; Bodendorfer, Blake M.; Laron, Dominique; Wong, Jason; Kim, Hubert T.; Liu, Xuhui; Feeley, Brian T.

    2013-01-01

    Introduction Rotator cuff tears are the most common injury seen by shoulder surgeons. Many late stage rotator cuff tear patients develop glenohumeral osteoarthritis as a result of torn cuff tendons, termed cuff tear arthropathy. However, the mechanisms of cuff tear arthropathy have not been fully established. It has been hypothesized that a combination of synovial and mechanical factors contribute equally to the development of cuff tear arthropathy. The goal of this study was to assess the utility of this model in investigating cuff-tear arthropathy. Methods We utilized a rat model which accurately reflects rotator cuff muscle degradation after massive rotator cuff tears through either infraspinatus and supraspinatus tenotomy or suprascapular nerve transection. Using a Modified-Mankin Scoring System (MMS), we found significant glenohumeral cartilage damage following both rotator cuff tenotomy and suprascapular nerve transection after only 12 weeks. Results Cartilage degeneration was similar between groups, and was present on both the humeral head and the glenoid. Denervation of the supraspinatus and infraspinatus muscles without opening the joint capsule caused cartilage degeneration similar to that found in the tendon transection group. Conclusions These results suggest that altered mechanical loading after rotator cuff tears is the primary factor in cartilage degeneration after rotator cuff tears. Clinically, understanding the process of cartilage degeneration after rotator cuff injury will help guide treatment decisions in the setting of rotator cuff tears. Level of evidence Basic Science Study, Animal Model PMID:23664745

  11. Does the Rotator Cuff Tear Pattern Influence Clinical Outcomes After Surgical Repair?

    PubMed

    Watson, Scott; Allen, Benjamin; Robbins, Chris; Bedi, Asheesh; Gagnier, Joel J; Miller, Bruce

    2018-03-01

    Limited literature exists regarding the influence of rotator cuff tear morphology on patient outcomes. To determine the effect of rotator cuff tear pattern (crescent, U-shape, L-shape) on patient-reported outcomes after rotator cuff repair. Cohort study; Level of evidence, 3. Patients undergoing arthroscopic repair of known full-thickness rotator cuff tears were observed prospectively at regular intervals from baseline to 1 year. The tear pattern was classified at the time of surgery as crescent, U-shaped, or L-shaped. Primary outcome measures were the Western Ontario Rotator Cuff Index (WORC), the American Shoulder and Elbow Surgeons (ASES), and a visual analog scale (VAS) for pain. The tear pattern was evaluated as the primary predictor while controlling for variables known to affect rotator cuff outcomes. Mixed-methods regression and analysis of variance (ANOVA) were used to examine the effects of tear morphology on patient-reported outcomes after surgical repair from baseline to 1 year. A total of 82 patients were included in the study (53 male, 29 female; mean age, 58 years [range, 41-75 years]). A crescent shape was the most common tear pattern (54%), followed by U-shaped (25%) and L-shaped tears (21%). There were no significant differences in outcome scores between the 3 groups at baseline. All 3 groups showed statistically significant improvement from baseline to 1 year, but analysis failed to show any predictive effect in the change in outcome scores from baseline to 1 year for the WORC, ASES, or VAS when tear pattern was the primary predictor. Further ANOVA also failed to show any significant difference in the change in outcome scores from baseline to 1 year for the WORC ( P = .96), ASES ( P = .71), or VAS ( P = .86). Rotator cuff tear pattern is not a predictor of functional outcomes after arthroscopic rotator cuff repair.

  12. Influence of fault trend, fault bends, and fault convergence on shallow structure, geomorphology, and hazards, Hosgri strike-slip fault, offshore central California

    NASA Astrophysics Data System (ADS)

    Johnson, S. Y.; Watt, J. T.; Hartwell, S. R.

    2012-12-01

    We mapped a ~94-km-long portion of the right-lateral Hosgri Fault Zone from Point Sal to Piedras Blancas in offshore central California using high-resolution seismic reflection profiles, marine magnetic data, and multibeam bathymetry. The database includes 121 seismic profiles across the fault zone and is perhaps the most comprehensive reported survey of the shallow structure of an active strike-slip fault. These data document the location, length, and near-surface continuity of multiple fault strands, highlight fault-zone heterogeneity, and demonstrate the importance of fault trend, fault bends, and fault convergences in the development of shallow structure and tectonic geomorphology. The Hosgri Fault Zone is continuous through the study area passing through a broad arc in which fault trend changes from about 338° to 328° from south to north. The southern ~40 km of the fault zone in this area is more extensional, resulting in accommodation space that is filled by deltaic sediments of the Santa Maria River. The central ~24 km of the fault zone is characterized by oblique convergence of the Hosgri Fault Zone with the more northwest-trending Los Osos and Shoreline Faults. Convergence between these faults has resulted in the formation of local restraining and releasing fault bends, transpressive uplifts, and transtensional basins of varying size and morphology. We present a hypothesis that links development of a paired fault bend to indenting and bulging of the Hosgri Fault by a strong crustal block translated to the northwest along the Shoreline Fault. Two diverging Hosgri Fault strands bounding a central uplifted block characterize the northern ~30 km of the Hosgri Fault in this area. The eastern Hosgri strand passes through releasing and restraining bends; the releasing bend is the primary control on development of an elongate, asymmetric, "Lazy Z" sedimentary basin. The western strand of the Hosgri Fault Zone passes through a significant restraining bend and

  13. Detection of endogenous cortisol in equine tears and blood at rest and after simulated stress.

    PubMed

    Monk, Caroline S; Hart, Kelsey A; Berghaus, Roy D; Norton, Natalie A; Moore, Phillip A; Myrna, Kathern E

    2014-07-01

    To determine whether cortisol is present in equine tears at rest and during simulated stress and compare tear cortisol to serum free and total cortisol. Fourteen healthy adult horses were included. Paired tear total cortisol and serum total and free cortisol concentrations were measured with ELISA, chemiluminescent immunoassay, and ultrafiltration methodology, respectively, in 10 horses at rest once daily for five consecutive days. In an additional four horses, paired tear and serum samples were collected for cortisol measurement before and after adrenocorticotropic hormone (ACTH) stimulation (cosyntropin, 1 μg/kg IV). Cortisol was detectable in equine tears at rest. Following ACTH stimulation, tear cortisol increased significantly from baseline at 60-120 min (P ≤ 0.001). Serum total and free cortisol also increased significantly at 30-180 min after ACTH stimulation (P ≤ 0.001). Both serum and tear cortisol returned to baseline concentrations by 360 min. Changes in tear cortisol were similarly associated with changes in serum total and free cortisol, although high tear cortisol concentrations suggest a portion of tear cortisol may be protein-bound. Cortisol is present in equine tears and increases in concert with serum cortisol following ACTH stimulation. Further study is needed to determine whether endogenous cortisol in tears contributes to ocular pathology. © 2013 American College of Veterinary Ophthalmologists.

  14. Peroneus longus tears associated with pathology of the os peroneum.

    PubMed

    Stockton, Kristopher G; Brodsky, James W

    2014-04-01

    There is a range of different types of tears and pathology of the peroneal tendons. One of the least common types is the tear of the peroneus longus associated with fracture, enlargement, or entrapment at the cuboid tunnel of the os peroneum. The purpose of this study was to evaluate the pathologic patterns of these uncommon peroneal tendon tears, to review the treatment, and to report the patient outcomes following treatment with excision of the os peroneum, debridement, and tenodesis of the peroneus longus to the peroneus brevis. A 5-year retrospective review of all patients with peroneal tendon tears identified 12 patients operatively treated for peroneus longus tendon tears with associated pathology of the os peroneum, and in whom there was a viable peroneus brevis. All patients were treated with an operative procedure consisting of excision of the os peroneum, debridement, and tenodesis of the peroneus longus to the peroneus brevis. Mean age was 51.5 (range, 33 to 73) years, including 7 males and 5 females. Operative and radiographic records were reviewed to characterize the nature of the peroneus longus tears and associated pathology. Preoperative and postoperative AOFAS hindfoot, SF-36 questionnaires, and Visual Analog Scale (VAS) pain scores were compiled and patient records were reviewed for complications. Mean follow-up after surgery was 63.3 (range, 12 to 114) months. All of the patients had an os peroneum associated with a complex, irreparable tear of the peroneus longus tendon. The peroneus longus was typically enlarged, fibrotic, and adhered to the surrounding tissues. In 8 patients, the peroneus longus tendon tear was associated with a fracture of the os peroneum, and in 4 patients with an enlarged and entrapped os peroneum which prevented movement at the cuboid tunnel. Of the 12 patients, 9 had partial tears of the peroneus brevis, which were treated with debridement and suture repair. AOFAS hindfoot scores increased from a preoperative mean of 61

  15. [Abnormal of tear lipid layer and recent advances in clinical study of dry eye].

    PubMed

    Xiao, Xin-Ye; Liu, Zu-Guo

    2012-03-01

    Dry eye is a common disease in the ophthalmological clinic, which is related to the dysfunction of tear film. The tear film is composed of lipid layer, aqueous layer and mucin layer (or lipid layer, aqueous/mucin layer). The lipid of the outmost layer derived from Meibomian gland and distributed on the tear film after blinking can decrease the evaporation and stabilize the tear film. The thickness, quality, and distribution of lipid layer are impaired in many dry eye patients, hence restoring the physiological function of lipid layer may be crucial for the treatment of this kind of dry eye. The lipid artificial tears manifest great effects on increasing lipid layer thickness, stabilizing tear film, improving Meibomian gland dysfunction, and promoting tear film distribution.

  16. FTAPE: A fault injection tool to measure fault tolerance

    NASA Technical Reports Server (NTRS)

    Tsai, Timothy K.; Iyer, Ravishankar K.

    1995-01-01

    The paper introduces FTAPE (Fault Tolerance And Performance Evaluator), a tool that can be used to compare fault-tolerant computers. The tool combines system-wide fault injection with a controllable workload. A workload generator is used to create high stress conditions for the machine. Faults are injected based on this workload activity in order to ensure a high level of fault propagation. The errors/fault ratio and performance degradation are presented as measures of fault tolerance.

  17. Fault compaction and overpressured faults: results from a 3-D model of a ductile fault zone

    NASA Astrophysics Data System (ADS)

    Fitzenz, D. D.; Miller, S. A.

    2003-10-01

    A model of a ductile fault zone is incorporated into a forward 3-D earthquake model to better constrain fault-zone hydraulics. The conceptual framework of the model fault zone was chosen such that two distinct parts are recognized. The fault core, characterized by a relatively low permeability, is composed of a coseismic fault surface embedded in a visco-elastic volume that can creep and compact. The fault core is surrounded by, and mostly sealed from, a high permeability damaged zone. The model fault properties correspond explicitly to those of the coseismic fault core. Porosity and pore pressure evolve to account for the viscous compaction of the fault core, while stresses evolve in response to the applied tectonic loading and to shear creep of the fault itself. A small diffusive leakage is allowed in and out of the fault zone. Coseismically, porosity is created to account for frictional dilatancy. We show in the case of a 3-D fault model with no in-plane flow and constant fluid compressibility, pore pressures do not drop to hydrostatic levels after a seismic rupture, leading to an overpressured weak fault. Since pore pressure plays a key role in the fault behaviour, we investigate coseismic hydraulic property changes. In the full 3-D model, pore pressures vary instantaneously by the poroelastic effect during the propagation of the rupture. Once the stress state stabilizes, pore pressures are incrementally redistributed in the failed patch. We show that the significant effect of pressure-dependent fluid compressibility in the no in-plane flow case becomes a secondary effect when the other spatial dimensions are considered because in-plane flow with a near-lithostatically pressured neighbourhood equilibrates at a pressure much higher than hydrostatic levels, forming persistent high-pressure fluid compartments. If the observed faults are not all overpressured and weak, other mechanisms, not included in this model, must be at work in nature, which need to be

  18. Two types of peak emotional responses to music: The psychophysiology of chills and tears

    PubMed Central

    Mori, Kazuma; Iwanaga, Makoto

    2017-01-01

    People sometimes experience a strong emotional response to artworks. Previous studies have demonstrated that the peak emotional experience of chills (goose bumps or shivers) when listening to music involves psychophysiological arousal and a rewarding effect. However, many aspects of peak emotion are still not understood. The current research takes a new perspective of peak emotional response of tears (weeping, lump in the throat). A psychophysiological experiment showed that self-reported chills increased electrodermal activity and subjective arousal whereas tears produced slow respiration during heartbeat acceleration, although both chills and tears induced pleasure and deep breathing. A song that induced chills was perceived as being both happy and sad whereas a song that induced tears was perceived as sad. A tear-eliciting song was perceived as calmer than a chill-eliciting song. These results show that tears involve pleasure from sadness and that they are psychophysiologically calming; thus, psychophysiological responses permit the distinction between chills and tears. Because tears may have a cathartic effect, the functional significance of chills and tears seems to be different. We believe that the distinction of two types of peak emotions is theoretically relevant and further study of tears would contribute to more understanding of human peak emotional response. PMID:28387335

  19. Evaluation of the Effects of Conjunctivochalasis Excision on Tear Stability and Contrast Sensitivity

    PubMed Central

    Qiu, Weiqiang; Zhang, Mingzhou; Xu, Ting; Liu, Ziyuan; Lv, Huibin; Wang, Wei; Li, Xuemin

    2016-01-01

    Conjunctivochalasis (CCh) disrupts tear flow and damages tear film stability. This study sought to evaluate the tear stability and contrast sensitivity of patients with CCh on whom CCh excision was performed. The study included 39 eyes from 39 patients; all patients had eyes with grade 2 or 3 CCh, underwent CCh excision, and were evaluated before and three months after the surgery. The evaluated variables included the ocular surface disease index (OSDI), the tear break-up time (TBUT), corneal fluorescein staining, corneal surface irregularity, Schirmer’s I test, the tear meniscus area (TMA), and contrast sensitivity. A follow-up of three months was achieved in 36 eyes for 36 patients. All parameters improved significantly after surgery (p < 0.05), except Schirmer’s I test, thus suggesting that CCh excision is an effective method for reconstructing the lower tear meniscus and improving both tear film stability and corneal surface irregularity. The results further demonstrated a simultaneous increase in contrast sensitivity after surgery. PMID:27892479

  20. Ipsilateral Medial and Lateral Discoid Meniscus with Medial Meniscus Tear

    PubMed Central

    Shimozaki, Kengo; Nakase, Junsuke; Ohashi, Yoshinori; Numata, Hitoaki; Oshima, Takeshi; Takata, Yasushi; Tsuchiya, Hiroyuki

    2016-01-01

    Introduction: Discoid meniscus is a well-documented knee pathology, and there are many cases of medial or lateral discoid meniscus reported in the literature. However, ipsilateral concurrent medial and lateral discoid meniscus is very rare, and only a few cases have been reported. Herein, we report a case of concurrent medial and lateral discoid meniscus. Case Report: A 27-year-old Japanese man complained of pain on medial joint space in his right knee that was diagnosed as a complete medial and lateral discoid meniscus. In magnetic resonance imaging, although the lateral discoid meniscus had no tear, the medial discoid meniscus had a horizontal tear. Arthroscopic examination of his right knee similarly revealed that the medial discoid meniscus had a horizontal tear. In addition, the discoid medial meniscus also had an anomalous insertion to the anterior cruciate ligament, and there was also mild fibrillation of the medial tibial cartilage surface. We performed arthroscopic partial meniscectomy for the torn medial discoid meniscus but not for the asymptomatic lateral discoid meniscus. The latest follow-up at 18 months indicated satisfactory results. Conclusion: We report a rare case of ipsilateral medial and lateral discoid meniscus with medial meniscus tear. The medial discoid meniscus with tear was treated with partial meniscectomy, whereas the lateral discoid meniscus without tear was only followed up. PMID:28164045

  1. Sartorius muscle tear presenting as acute meralgia paresthetica.

    PubMed

    Lee, Brian; Stubbs, Euan

    2018-05-29

    We present an unusual case of sartorius muscle tear presenting as acute meralgia paresthetica. A healthy 67-year old male was referred to our department with a one-week history of pain, numbness and bruising over his hip and anterolateral thigh. Extended ultrasound assessment revealed an intramuscular tear of sartorius, with acute hematoma surrounding the adjacent lateral femoral cutaneous nerve. Meralgia paresthetica from acute trauma is rare, with only three published cases relating to fractures of the anterior superior iliac spine. To our knowledge, this is the first case caused by muscular tear in the literature. The presence of features attributable to neuropraxia of the lateral femoral cutaneous nerve allowed for proper localization and diagnosis of the patient's injury. Copyright © 2018. Published by Elsevier Inc.

  2. Improved alignment of the Hengchun Fault (southern Taiwan) based on fieldwork, structure-from-motion, shallow drilling, and levelling data

    NASA Astrophysics Data System (ADS)

    Giletycz, Slawomir Jack; Chang, Chung-Pai; Lin, Andrew Tien-Shun; Ching, Kuo-En; Shyu, J. Bruce H.

    2017-11-01

    The fault systems of Taiwan have been repeatedly studied over many decades. Still, new surveys consistently bring fresh insights into their mechanisms, activity and geological characteristics. The neotectonic map of Taiwan is under constant development. Although the most active areas manifest at the on-land boundary of the Philippine Sea Plate and Eurasia (a suture zone known as the Longitudinal Valley), and at the southwestern area of the Western Foothills, the fault systems affect the entire island. The Hengchun Peninsula represents the most recently emerged part of the Taiwan orogen. This narrow 20-25 km peninsula appears relatively aseismic. However, at the western flank the peninsula manifests tectonic activity along the Hengchun Fault. In this study, we surveyed the tectonic characteristics of the Hengchun Fault. Based on fieldwork, four years of monitoring fault displacement in conjunction with levelling data, core analysis, UAV surveys and mapping, we have re-evaluated the fault mechanisms as well as the geological formations of the hanging and footwall. We surveyed features that allowed us to modify the existing model of the fault in two ways: 1) correcting the location of the fault line in the southern area of the peninsula by moving it westwards about 800 m; 2) defining the lithostratigraphy of the hanging and footwall of the fault. A bathymetric map of the southern area of the Hengchun Peninsula obtained from the Atomic Energy Council that extends the fault trace offshore to the south distinctively matches our proposed fault line. These insights, coupled with crust-scale tomographic data from across the Manila accretionary system, form the basis of our opinion that the Hengchun Fault may play a major role in the tectonic evolution of the southern part of the Taiwan orogen.

  3. Effectiveness Of Plain Shoulder Radiograph In Detecting Degenerate Rotator Cuff Tears.

    PubMed

    Hussain, Adnan; Muzzammil, Muhammad; Butt, Faisal; Valsamis, Epaminondas Markos; Dwyer, Amitabh J

    2018-01-01

    Studies have demonstrated radiographic findings of sclerosis and cortical irregularity at the greater tuberosity can suggest a rotator cuff tear. Plain radiographs are the most easily attainable first-line investigations in evaluating shoulder injuries. This study determines the effectiveness in predicting degenerate rotator cuff tears by detecting radiographic changes on shoulder x-rays. Retrospective cross-sectional study with a consecutive series of patients conducted in Hinchingbrooke Hospital, Huntingdon, United Kingdom from January 2015 to June 2017. Anteroposterior shoulder radiographs of 150 symptomatic patients who underwent shoulder arthroscopy were independently analysed by surgeons who were blinded from the arthroscopic results. Patients aged fewer than 30 and over 70 years were excluded. Patients with advanced osteoarthritis and cuff tear arthropathy evident on x-rays were also excluded. Sixty-five patients included in the study had rotator cuff tears on arthroscopy. Radiographic changes were correlated with arthroscopic findings to determine this test's ability to predict degenerate rotator cuff tears. When both cortical irregularity and sclerosis were present on the plain radiograph, these signs had a sensitivity of 78.8% [95% CI 65.7, 87.8%] and specificity 77.4% [95% CI 67.2, 85.0%] with a positive predictive value of 68.3%, using contingency table analysis. The presence of cortical irregularity was found to be a better predictor of a tear as compared to sclerosis. This study concludes that plain radiograph are good modality for initial evaluation of rotator cuff tears and detecting when both cortical irregularity and sclerosis. Consideration of these radiographic findings serves as a useful adjunct in diagnostic workup and can guide subsequent investigations and treatment when evaluating rotator cuff tears of the shoulder.

  4. The effect of benoxinate on the tear stability of Hong Kong-Chinese.

    PubMed

    Cho, P; Brown, B

    1995-07-01

    We conducted a series of experiments to examine the effect of local anaesthetic instillation on tear stability measurements. All experiments were conducted with the examiner masked with respect to treatments. We measured tear break-up time (TDUT) and non-invasive tear break-up time (NITBUT) 30s after instillation of benoxinate (0.4%) in a single masked experiment and found that NITBUT was significantly increased while TBUT was unaffected. In separate experiments tear stability was assessed 5 min after instillation of benoxinate and there was no significant effect on either TBUT or NITBUT measurements. In a control experiment to examine the effect of instilling a drop of liquid into the eye, neither TBUT nor NITBUT were affected 30s after the instillation of saline. No corneal staining was observed in any of the subjects after instillation of benoxinate. The results suggest that benoxinate does not affect the stability of the precorneal tear film, and that tear stability can be assessed after the instillation of unpreserved benoxinate.

  5. Validation of a new classification system for skin tears.

    PubMed

    LeBlanc, Kimberly; Baranoski, Sharon; Holloway, Samantha; Langemo, Diane

    2013-06-01

    The aim of this study was to validate and establish reliability of the International Skin Tear classification system. A consensus panel of 12 internationally recognized key opinion leaders convened in 2011 to establish consensus statements on the prevention, prediction, assessment, and treatment of skin tears. Subsequently, a new skin tear classification system was proposed. The system was then tested for interrater and intrarater reliability between the experts before being tested more widely on a sample of 327 individuals from the United States, Canada, and Europe. The results of the study indicated a substantial level of agreement for the expert panel (Fleiss κ = 0.619; 2-month follow-up = 0.653). Intrarater reliability was high (Cohen κ = 0.877). Interrater reliability was moderate (Fleiss κ = 0.555) for healthcare professionals (n = 303) and fair for non-health professionals (Fleiss κ = 0.338; n = 24). This international study established the reliability and validity of a new classification system for skin tears.

  6. The Importance of Correct Diagnosis of Crocodile Tears Syndrome.

    PubMed

    de Oliveira, Danila; Gomes-Ferreira, Pedro Henrique Silva; Carrasco, Leandro Carlos; de Deus, Ciro Borges Duailibe; Garcia-Júnior, Idelmo Rangel; Faverani, Leonardo Perez

    2016-10-01

    The excessive unilateral tearing as a result of gustatory stimuli is a characteristic of crocodile tears syndromes. The aim of this study is to report 2 cases of Frey and crocodile tears syndromes, considering diagnosis, monitoring, and selection of appropriate treatment. A 74-year-old female patient presented with a history of Bell palsy, tearing on left eye at the moment of chewing, and absence of pain. The patient opted only for periodic case monitoring because the symptoms presented by the syndrome did not bother her, which made any invasive procedure unnecessary, and with the closed diagnosis she may be reassured and really know what was happening to her. So scientific divulgations about this syndrome should be made in order to increase the knowledge of dentists and oral and maxillofacial surgeons, because it is a rare syndrome and easily diagnosed. Due to the low knowledge in Brazil, the patient of this report had to wait about 9 years to get a diagnosis.

  7. Tearing mode dynamics and sawtooth oscillation in Hall-MHD

    NASA Astrophysics Data System (ADS)

    Ma, Zhiwei; Zhang, Wei; Wang, Sheng

    2017-10-01

    Tearing mode instability is one of the most important dynamic processes in space and laboratory plasmas. Hall effects, resulted from the decoupling of electron and ion motions, could cause the fast development and perturbation structure rotation of the tearing mode and become non-negligible. We independently developed high accuracy nonlinear MHD code (CLT) to study Hall effects on the dynamic evolution of tearing modes with Tokamak geometries. It is found that the rotation frequency of the mode in the electron diamagnetic direction is in a good agreement with analytical prediction. The linear growth rate increases with increase of the ion inertial length, which is contradictory to analytical solution in the slab geometry. We further find that the self-consistently generated rotation largely alters the dynamic behavior of the double tearing mode and the sawtooth oscillation. National Magnetic Confinement Fusion Science Program of China under Grant No. 2013GB104004 and 2013GB111004.

  8. Evaluation of meniscus tears of the knee by radionuclide imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marymont, J.V.; Lynch, M.A.; Henning, C.E.

    We compare the accuracy of radionuclide imaging of the knee with Tc99m-pyrophosphate with arthrography for the evaluation of meniscus tears in young athletes with clinically suspected knee injury. All patients had arthroscopy which was used as the standard against which the other two diagnostic procedures were compared. Radionuclide scintigraphy and arthrography were comparable in their ability to detect tears of the medial meniscus. Scintigraphy was superior for the detection of tears of the lateral meniscus and of both menisci.

  9. Dynamics and function of the tear film in relation to the blink cycle.

    PubMed

    Braun, R J; King-Smith, P E; Begley, C G; Li, Longfei; Gewecke, N R

    2015-03-01

    Great strides have recently been made in quantitative measurements of tear film thickness and thinning, mathematical modeling thereof and linking these to sensory perception. This paper summarizes recent progress in these areas and reports on new results. The complete blink cycle is used as a framework that attempts to unify the results that are currently available. Understanding of tear film dynamics is aided by combining information from different imaging methods, including fluorescence, retroillumination and a new high-speed stroboscopic imaging system developed for studying the tear film during the blink cycle. During the downstroke of the blink, lipid is compressed as a thick layer just under the upper lid which is often released as a narrow thick band of lipid at the beginning of the upstroke. "Rippling" of the tear film/air interface due to motion of the tear film over the corneal surface, somewhat like the flow of water in a shallow stream over a rocky streambed, was observed during lid motion and treated theoretically here. New mathematical predictions of tear film osmolarity over the exposed ocular surface and in tear breakup are presented; the latter is closely linked to new in vivo observations. Models include the effects of evaporation, osmotic flow through the cornea and conjunctiva, quenching of fluorescence, tangential flow of aqueous tears and diffusion of tear solutes and fluorescein. These and other combinations of experiment and theory increase our understanding of the fluid dynamics of the tear film and its potential impact on the ocular surface. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Dynamics and function of the tear film in relation to the blink cycle

    PubMed Central

    Braun, R.J.; King-Smith, P.E.; Begley, C.G.; Li, Longfei; Gewecke, N.R.

    2014-01-01

    Great strides have recently been made in quantitative measurements of tear film thickness and thinning, mathematical modeling thereof and linking these to sensory perception. This paper summarizes recent progress in these areas and reports on new results. The complete blink cycle is used as a framework that attempts to unify the results that are currently available. Understanding of tear film dynamics is aided by combining information from different imaging methods, including fluorescence, retroillumination and a new high-speed stroboscopic imaging system developed for studying the tear film during the blink cycle. During the downstroke of the blink, lipid is compressed as a thick layer just under the upper lid which is often released as a narrow thick band of lipid at the beginning of the upstroke. “Rippling” of the tear film/air interface due to motion of the tear film over the corneal surface, somewhat like the flow of water in a shallow stream over a rocky streambed, was observed during lid motion and treated theoretically here. New mathematical predictions of tear film osmolarity over the exposed ocular surface and in tear breakup are presented; the latter is closely linked to new in vivo observations. Models include the effects of evaporation, osmotic flow through the cornea and conjunctiva, quenching of fluorescence, tangential flow of aqueous tears and diffusion of tear solutes and fluorescein. These and other combinations of experiment and theory increase our understanding of the fluid dynamics of the tear film and its potential impact on the ocular surface. PMID:25479602

  11. Flight elements: Fault detection and fault management

    NASA Technical Reports Server (NTRS)

    Lum, H.; Patterson-Hine, A.; Edge, J. T.; Lawler, D.

    1990-01-01

    Fault management for an intelligent computational system must be developed using a top down integrated engineering approach. An approach proposed includes integrating the overall environment involving sensors and their associated data; design knowledge capture; operations; fault detection, identification, and reconfiguration; testability; causal models including digraph matrix analysis; and overall performance impacts on the hardware and software architecture. Implementation of the concept to achieve a real time intelligent fault detection and management system will be accomplished via the implementation of several objectives, which are: Development of fault tolerant/FDIR requirement and specification from a systems level which will carry through from conceptual design through implementation and mission operations; Implementation of monitoring, diagnosis, and reconfiguration at all system levels providing fault isolation and system integration; Optimize system operations to manage degraded system performance through system integration; and Lower development and operations costs through the implementation of an intelligent real time fault detection and fault management system and an information management system.

  12. Behavioral and neural responses to infant and adult tears: The impact of maternal love withdrawal.

    PubMed

    Riem, Madelon M E; van IJzendoorn, Marinus H; De Carli, Pietro; Vingerhoets, Ad J J M; Bakermans-Kranenburg, Marian J

    2017-09-01

    The current study examined behavioral and neural responses to infant and adult tears, taking into account childhood experiences with parental love-withdrawal. With functional MRI (fMRI), we measured neural reactivity to pictures of infants and adults with and without tears on their faces in nulliparous women with varying childhood experiences of maternal use of love withdrawal. Behavioral responses to infant and adult tears were measured with an approach-avoidance task. We found that individuals with experiences of love withdrawal showed less amygdala and insula reactivity to adult tears, but love withdrawal did not affect amygdala and insula reactivity to infant tears. During the approach-avoidance task, individuals responded faster to adult tears in the approach condition compared with the avoidance condition, indicating that adult tears facilitate approach behavior. Individuals responded faster to infant tears than to adult tears, regardless of approach or avoidance condition. Our findings suggest that infant tears are highly salient and may, therefore, overrule the effects of contextual and personal characteristics that influence the perception of adult crying. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  13. Advanced glycation end product (AGE) modified proteins in tears of diabetic patients.

    PubMed

    Zhao, Zhenjun; Liu, Jingfang; Shi, Bingyin; He, Shuixiang; Yao, Xiaoli; Willcox, Mark D P

    2010-08-11

    High glucose level in diabetic patients may lead to advanced glycation end product (AGE) modified proteins. This study investigated AGE modified proteins in tears and compared their levels in diabetic patients (DM) with non-diabetic controls (CTL). Basal tears were collected from DM with (DR) or without (DNR) retinopathy and CTL. Total AGE modified proteins were detected quantitatively by a dot immunobinding assay. The AGE modified proteins were separated in 1D- and 2D-SDS gels and detected by western-blotting. The individual AGE modified proteins were also compared between groups using densitometry. Compared with the CTL group, tear concentrations of AGE modified proteins were significantly elevated in DR and DNR groups. The concentration of AGE modified proteins in diabetic tears were positively correlated with AGE modified hemoglobin (HbA1c) and postprandial blood glucose level (PBG). Western blotting of AGE modified proteins from 1D-SDS gels showed several bands, the major one at around 60 kDa. The intensities of AGE modified protein bands were higher in DM tears than in CTL tears. Western blotting from 2D-SDS gels showed a strongly stained horizontal strip, which corresponded to the major band in 1D-SDS gels. Most of the other AGE modified protein species were within molecular weight of 30-60 kDa, PI 5.2-7.0. Densitometry analysis demonstrated several AGE modified proteins were elevated in DR or DNR tears. Total and some individual AGE modified proteins were elevated in DM tears. AGE modified proteins in tears may be used as biomarkers to diagnose diabetes and/or diabetic retinopathy.

  14. Microarray-based IgE detection in tears of patients with vernal keratoconjunctivitis.

    PubMed

    Leonardi, Andrea; Borghesan, Franco; Faggian, Diego; Plebani, Mario

    2015-11-01

    A specific allergen sensitization can be demonstrated in approximately half of the vernal keratoconjunctivitis (VKC) patients by conventional allergic tests. The measurement of specific IgE in tears using a multiplex allergen microarray may offer advantages to identify local sensitization to a specific allergen. In spring-summer 2011, serum and tears samples were collected from 10 active VKC patients (three females, seven males) and 10 age-matched normal subjects. Skin prick test, symptoms score and full ophthalmological examination were performed. Specific serum and tear IgE were assayed using ImmunoCAP ISAC, a microarray containing 103 components derived from 47 allergens. Normal subjects resulted negative for the presence of specific IgE both in serum and in tears. Of the 10 VKC patients, six resulted positive to specific IgE in serum and/or tears. In three of these six patients, specific IgE was found positive only in tears. Cross-reactivity between specific markers was found in three patients. Grass, tree, mites, animal but also food allergen-specific IgE were found in tears. Conjunctival provocation test performed out of season confirmed the specific local conjunctival reactivity. Multiple specific IgE measurements with single protein allergens using a microarray technique in tear samples are a useful, simple and non-invasive diagnostic tool. ImmunoCAP ISAC detects allergen sensitization at component level and adds important information by defining both cross- and co-sensitization to a large variety of allergen molecules. The presence of specific IgE only in tears of VKC patients reinforces the concept of possible local sensitization. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Over the counter (OTC) artificial tear drops for dry eye syndrome.

    PubMed

    Pucker, Andrew D; Ng, Sueko M; Nichols, Jason J

    2016-02-23

    Over the counter (OTC) artificial tears historically have been the first line of treatment for dry eye syndrome and dry eye-related conditions like contact lens discomfort, yet currently we know little regarding the overall efficacy of individual, commercially available artificial tears. This review provides a much needed meta-analytical look at all randomized and quasi-randomized clinical trials that have analyzed head-to-head comparisons of OTC artificial tears. To evaluate the effectiveness and toxicity of OTC artificial tear applications in the treatment of dry eye syndrome compared with another class of OTC artificial tears, no treatment, or placebo. We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2015, Issue 12), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to December 2015), EMBASE (January 1980 to December 2015), Latin American and Caribbean Health Sciences (LILACS) (January 1982 to December 2015), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov), the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en) and the US Food and Drugs Administration (FDA) website (www.fda.gov). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 4 December 2015. We searched reference lists of included trials for any additional trials not identified by the electronic searches. This review includes randomized controlled trials with adult participants who were diagnosed with dry eye, regardless of race and gender. We included trials in which the age of participants was not reported, and clinical trials comparing OTC artificial tears with another class of OTC artificial tears, placebo, or no treatment. This review did not consider head-to-head comparisons of artificial tears with

  16. Fault-related clay authigenesis along the Moab Fault: Implications for calculations of fault rock composition and mechanical and hydrologic fault zone properties

    USGS Publications Warehouse

    Solum, J.G.; Davatzes, N.C.; Lockner, D.A.

    2010-01-01

    The presence of clays in fault rocks influences both the mechanical and hydrologic properties of clay-bearing faults, and therefore it is critical to understand the origin of clays in fault rocks and their distributions is of great importance for defining fundamental properties of faults in the shallow crust. Field mapping shows that layers of clay gouge and shale smear are common along the Moab Fault, from exposures with throws ranging from 10 to ???1000 m. Elemental analyses of four locations along the Moab Fault show that fault rocks are enriched in clays at R191 and Bartlett Wash, but that this clay enrichment occurred at different times and was associated with different fluids. Fault rocks at Corral and Courthouse Canyons show little difference in elemental composition from adjacent protolith, suggesting that formation of fault rocks at those locations is governed by mechanical processes. Friction tests show that these authigenic clays result in fault zone weakening, and potentially influence the style of failure along the fault (seismogenic vs. aseismic) and potentially influence the amount of fluid loss associated with coseismic dilation. Scanning electron microscopy shows that authigenesis promotes that continuity of slip surfaces, thereby enhancing seal capacity. The occurrence of the authigenesis, and its influence on the sealing properties of faults, highlights the importance of determining the processes that control this phenomenon. ?? 2010 Elsevier Ltd.

  17. The Trans-Rocky Mountain Fault System - A Fundamental Precambrian Strike-Slip System

    USGS Publications Warehouse

    Sims, P.K.

    2009-01-01

    Recognition of a major Precambrian continental-scale, two-stage conjugate strike-slip fault system - here designated as the Trans-Rocky Mountain fault system - provides new insights into the architecture of the North American continent. The fault system consists chiefly of steep linear to curvilinear, en echelon, braided and branching ductile-brittle shears and faults, and local coeval en echelon folds of northwest strike, that cut indiscriminately across both Proterozoic and Archean cratonic elements. The fault system formed during late stages of two distinct tectonic episodes: Neoarchean and Paleoproterozoic orogenies at about 2.70 and 1.70 billion years (Ga). In the Archean Superior province, the fault system formed (about 2.70-2.65 Ga) during a late stage of the main deformation that involved oblique shortening (dextral transpression) across the region and progressed from crystal-plastic to ductile-brittle deformation. In Paleoproterozoic terranes, the fault system formed about 1.70 Ga, shortly following amalgamation of Paleoproterozoic and Archean terranes and the main Paleoproterozoic plastic-fabric-producing events in the protocontinent, chiefly during sinistral transpression. The postulated driving force for the fault system is subcontinental mantle deformation, the bottom-driven deformation of previous investigators. This model, based on seismic anisotropy, invokes mechanical coupling and subsequent shear between the lithosphere and the asthenosphere such that a major driving force for plate motion is deep-mantle flow.

  18. Diagnostic imaging of the nasolacrimal drainage system. Part I. Radiological anatomy of lacrimal pathways. Physiology of tear secretion and tear outflow.

    PubMed

    Maliborski, Artur; Różycki, Radosław

    2014-04-17

    Excessive watering of the eye is a common condition in ophthalmological practice. It may be the result of excessive production of tear fluid or obstruction and insufficiency of efferent tear pathways. The differentiation between obstruction and insufficiency of the lacrimal pathways is still clinically questionable. In the diagnostic process it is necessary to perform clinical tests and additional diagnostic imaging is often needed. Dacryocystography, with or without the extension of the dynamic phase or subtraction option, still remains the criterion standard for diagnostic imaging of the lacrimal obstruction. It may help to clarify the cause and exact place of the obstruction and provide information for further management, especially surgical treatment. Increasingly, new techniques are used in diagnostic imaging of the lacrimal tract, such as computed tomography, magnetic resonance, and isotopic methods. Adequate knowledge of the anatomy and physiology of the lacrimal system and the secretion and outflow of tears is the basis for proper diagnostic imaging. The purpose of this paper is to present the exact anatomy of the lacrimal system, with particular emphasis on the radiological anatomy and the current state of knowledge about the physiology of tear secretion and drainage.

  19. Mechanical evolution of transpression zones affected by fault interactions: Insights from 3D elasto-plastic finite element models

    NASA Astrophysics Data System (ADS)

    Nabavi, Seyed Tohid; Alavi, Seyed Ahmad; Mohammadi, Soheil; Ghassemi, Mohammad Reza

    2018-01-01

    The mechanical evolution of transpression zones affected by fault interactions is investigated by a 3D elasto-plastic mechanical model solved with the finite-element method. Ductile transpression between non-rigid walls implies an upward and lateral extrusion. The model results demonstrate that a, transpression zone evolves in a 3D strain field along non-coaxial strain paths. Distributed plastic strain, slip transfer, and maximum plastic strain occur within the transpression zone. Outside the transpression zone, fault slip is reduced because deformation is accommodated by distributed plastic shear. With progressive deformation, the σ3 axis (the minimum compressive stress) rotates within the transpression zone to form an oblique angle to the regional transport direction (∼9°-10°). The magnitude of displacement increases faster within the transpression zone than outside it. Rotation of the displacement vectors of oblique convergence with time suggests that transpression zone evolves toward an overall non-plane strain deformation. The slip decreases along fault segments and with increasing depth. This can be attributed to the accommodation of bulk shortening over adjacent fault segments. The model result shows an almost symmetrical domal uplift due to off-fault deformation, generating a doubly plunging fold and a 'positive flower' structure. Outside the overlap zone, expanding asymmetric basins subside to 'negative flower' structures on both sides of the transpression zone and are called 'transpressional basins'. Deflection at fault segments causes the fault dip fall to less than 90° (∼86-89°) near the surface (∼1.5 km). This results in a pure-shear-dominated, triclinic, and discontinuous heterogeneous flow of the transpression zone.

  20. A very rare case of bloody tears with enigmatic epistaxis and haematuria.

    PubMed

    Ho, Jason Z S; de Silva, Julian; Olver, Jane

    2011-03-01

    Bloody tears are a rare symptom that can be caused by local or systemic pathology. We describe a very rare case of bloody tears that resulted from hyperthyroidism. A 15-year-old female patient presented with a 6-month history of bloody tears and epistaxis. Examination excluded local ocular and nasal pathology, including neoplasm and coagulopathy. Systemic investigations identified elevated thyroid function and following treatment her symptoms resolved. We discuss the mechanism by which hyperthyroidism may induce haemostatic dysfunction. We present the first case of bloody tears secondary to thyroid dysfunction.

  1. Pharmacokinetic analysis of topical tobramycin in equine tears by automated immunoassay.

    PubMed

    Czerwinski, Sarah L; Lyon, Andrew W; Skorobohach, Brian; Léguillette, Renaud

    2012-08-21

    Ophthalmic antibiotic therapy in large animals is often used empirically because of the lack of pharmacokinetics studies. The purpose of the study was to determine the pharmacokinetics of topical tobramycin 0.3% ophthalmic solution in the tears of normal horses using an automated immunoassay analysis. The mean tobramycin concentrations in the tears at 5, 10, 15, 30 minutes and 1, 2, 4, 6 hours after administration were 759 (±414), 489 (±237), 346 (±227), 147 (±264), 27.6 (±28.4), 14.8 (±66.6), 6.7 (±18.6), and 23.4 (±73.4) mg/L. Mean tobramycin concentration was maintained above the MIC90 for commonly isolated bacteria for 68.5 min. A single dose of topical tobramycin resulted in therapeutic concentrations of tobramycin in the tears for 1 h after administration. Therapeutic levels of tobramycin remained in equine tears 6 times longer than was reported in rabbit tears.

  2. Metabolomics and Trace Element Analysis of Camel Tear by GC-MS and ICP-MS.

    PubMed

    Ahamad, Syed Rizwan; Raish, Mohammad; Yaqoob, Syed Hilal; Khan, Altaf; Shakeel, Faiyaz

    2017-06-01

    Camel tear metabolomics and elemental analysis are useful in getting the information regarding the components responsible for maintaining the protective system that allows living in the desert and dry regions. The aim of this study was to correlate that the camel tears can be used as artificial tears for the evaluation of dryness in the eye. Eye biomarkers of camel tears were analyzed by gas chromatography-mass spectroscopy (GC-MS) and inductively coupled plasma mass spectroscopy (ICP-MS). The major compounds detected in camel tears by GC-MS were alanine, valine, leucine, norvaline, glycine, cadaverine, urea, ribitol, sugars, and higher fatty acids like octadecanoic acid and hexadecanoic acid. GC-MS analysis of camel tears also finds several products of metabolites and its associated metabolic participants. ICP-MS analysis showed the presence of different concentration of elemental composition in the camel tears.

  3. Time course of changes in tear meniscus radius and blink rate after instillation of artificial tears.

    PubMed

    Bandlitz, Stefan; Purslow, Christine; Murphy, Paul J; Pult, Heiko

    2014-08-26

    Using a novel digital meniscometer (PDM), alterations in tear meniscus radius (TMR) were measured simultaneously with blink rate (BR) following the instillation of artificial tears. Central TMR and BR of 22 subjects (11 male and 11 female; mean age, 24.3 ± 2.6 SD years) were measured at baseline, and 0, 1, 5, 10, and 30 minutes after instillation of an artificial tear containing hydroxypropyl-guar and glycol (SYS) or saline (SAL). A dose of 35 μL was applied in one eye in a randomized order with a washout period between each drop. For SAL, compared to baseline TMR (0.33 ± 0.08 mm), TMR significantly increased with drop instillation (1.55 ± 0.69 mm) and at 1 minute (0.66 ± 0.36 mm; P < 0.05), but returned to baseline after 5 minutes. For SYS, TMR (0.32 ± 0.07 mm) remained significantly increased after application (1.62 ± 0.81 mm), and at 1 minute (0.81 ± 0.43 mm) and 5 minutes (0.39 ± 0.08 mm; P < 0.05). Compared to baseline BR with SAL (14.8 ± 7.7) and SYS (14.9 ± 9.4), values were significantly increased upon drop instillation (22.5 ± 11.8; 21.3 ± 11.8; P < 0.05), but returned to baseline after 1 minute. Dry eye symptoms were correlated with baseline BR (r = 0.550, P = 0.008). Results indicate that PDM can detect changes in TMR following instillation of artificial tears. Difference in residence time reflects the different viscosity of each drop. An overload with a large drop may result in an initially increased BR. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  4. Subregional effects of meniscal tears on cartilage loss over 2 years in knee osteoarthritis.

    PubMed

    Chang, Alison; Moisio, Kirsten; Chmiel, Joan S; Eckstein, Felix; Guermazi, Ali; Almagor, Orit; Cahue, September; Wirth, Wolfgang; Prasad, Pottumarthi; Sharma, Leena

    2011-01-01

    Meniscal tears have been linked to knee osteoarthritis progression, presumably by impaired load attenuation. How meniscal tears affect osteoarthritis is unclear; subregional examination may help to elucidate whether the impact is local. This study examined the association between a tear within a specific meniscal segment and subsequent 2-year cartilage loss in subregions that the torn segment overlies. Participants with knee osteoarthritis underwent bilateral knee MRI at baseline and 2 years. Mean cartilage thickness within each subregion was quantified. Logistic regression with generalised estimating equations were used to analyse the relationship between baseline meniscal tear in each segment and baseline to 2-year cartilage loss in each subregion, adjusting for age, gender, body mass index, tear in the other two segments and extrusion. 261 knees were studied in 159 individuals. Medial meniscal body tear was associated with cartilage loss in external subregions and in central and anterior tibial subregions, and posterior horn tear specifically with posterior tibial subregion loss; these relationships were independent of tears in the other segments and persisted in tibial subregions after adjustment for extrusion. Lateral meniscal body and posterior horn tear were also associated with cartilage loss in underlying subregions but not after adjustment for extrusion. Cartilage loss in the internal subregions, not covered by the menisci, was not associated with meniscal tear in any segment. These results suggest that the detrimental effect of meniscal tears is not spatially uniform across the tibial and femoral cartilage surfaces and that some of the effect is experienced locally.

  5. Dynamic measurement of the corneal tear film with a Twyman-Green interferometer

    NASA Astrophysics Data System (ADS)

    Micali, Jason D.; Greivenkamp, John E.; Primeau, Brian C.

    2014-07-01

    An interferometer for measuring dynamic properties of the in vivo tear film on the human cornea has been developed. The system is a near-infrared instantaneous phase-shifting Twyman-Green interferometer. The laser source is a 785 nm solidstate laser; the system has been carefully designed and calibrated to ensure that the system operates at eye safe levels. Measurements are made over a 6 mm diameter on the cornea. Successive frames of interferometric height measurements are combined to produce movies showing both the quantitative and qualitative changes in the topography of the tear film surface and structure. To date, measurement periods of up to 120 seconds at 28.6 frames per second have been obtained. Several human subjects have been examined using this system, demonstrating a surface height resolution of 25 nm and spatial resolution of 6 μm. Examples of features that have been observed in these in preliminary studies of the tear film include: post-blink disruption, evolution, and stabilization of the tear film; tear film artifacts generated by blinking; tear film evaporation and break-up; and the propagation of foreign objects in the tear film. This paper discusses the interferometer design and presents results from in vivo measurements.

  6. Dynamic measurement of the corneal tear film with a Twyman-Green interferometer

    NASA Astrophysics Data System (ADS)

    Micali, Jason D.; Greivenkamp, John E.; Primeau, Brian C.

    2015-05-01

    An interferometer for measuring dynamic properties of the in vivo tear film on the human cornea has been developed. The system is a near-infrared instantaneous phase-shifting Twyman-Green interferometer. The laser source is a 785 nm solid-state laser, and the system has been carefully designed and calibrated to ensure that the system operates at eye-safe levels. Measurements are made over a 6 mm diameter on the cornea. Successive frames of interferometric height measurements are combined to produce movies showing both the quantitative and qualitative changes in the topography of the tear film surface and structure. To date, measurement periods of up to 120 s at 28.6 frames per second have been obtained. Several human subjects have been examined using this system, demonstrating a surface height resolution of 25 nm and spatial resolution of 6 μm. Examples of features that have been observed in these preliminary studies of the tear film include postblink disruption, evolution, and stabilization of the tear film; tear film artifacts generated by blinking; tear film evaporation and breakup; and the propagation of foreign objects in the tear film. This paper discusses the interferometer design and presents results from in vivo measurements.

  7. Migrating tremors illuminate complex deformation beneath the seismogenic San Andreas fault

    USGS Publications Warehouse

    Shelly, David R.

    2010-01-01

    The San Andreas fault is one of the most extensively studied faults in the world, yet its physical character and deformation mode beneath the relatively shallow earthquake-generating portion remain largely unconstrained. Tectonic ‘non-volcanic’ tremor, a recently discovered seismic signal probably generated by shear slip on the deep extension of some major faults, can provide new insight into the deep fate of such faults, including that of the San Andreas fault near Parkfield, California. Here I examine continuous seismic data from mid-2001 to 2008, identifying tremor and decomposing the signal into different families of activity based on the shape and timing of the waveforms at multiple stations. This approach allows differentiation between activities from nearby patches of the deep fault and begins to unveil rich and complex patterns of tremor occurrence. I find that tremor exhibits nearly continuous migration, with the most extensive episodes propagating more than 20 kilometres along fault strike at rates of 15–80 kilometres per hour. This suggests that the San Andreas fault remains a localized through-going structure, at least to the base of the crust, in this area. Tremor rates and recurrence behaviour changed markedly in the wake of the 2004 magnitude-6.0 Parkfield earthquake, but these changes were far from uniform within the tremor zone, probably reflecting heterogeneous fault properties and static and dynamic stresses decaying away from the rupture. The systematic recurrence of tremor demonstrated here suggests the potential to monitor detailed time-varying deformation on this portion of the deep San Andreas fault, deformation which unsteadily loads the shallower zone that last ruptured in the 1857 magnitude-7.9 Fort Tejon earthquake.

  8. MRI of lesser metatarsophalangeal joint plantar plate tears and associated adjacent interspace lesions.

    PubMed

    Umans, Hilary; Srinivasan, Ramya; Elsinger, Elisabeth; Wilde, Gregory E

    2014-10-01

    To identify the variety of second and third intermetatarsal space (IS) lesions that may coexist with and without adjacent metatarsophalangeal joint (MTP) plantar plate (PP) tears. One hundred forefoot MRIs in 96 patients with metatarsalgia obtained between 30 September 2011 and 21 July 2012 using 1.5- or 3-T MRI were retrospectively reviewed in consensus by two MSK radiologists and one podiatrist (DPM). MRI was evaluated for second and third MTP PP tear and the presence/nature of second and third IS lesions. Second and third IS neuromas were measured in transverse (trans) dimension. A total of 40 PP tears were identified: 36 at the second and 4 at the third MTP. Second MTP PP tear was identified in 33% of females and 40.5% of males. In the 63 female feet there were 21 second MTP PP tears, all of which also had second IS lesions: pericapsular fibrosis (16), bursitis (4), and ganglion (1). In the 37 male feet there were 15 second MTP PP tears, 14 of which had second IS lesions: pericapsular fibrosis (8), bursitis (5), and ganglion (1). There was no definite second IS neuroma adjacent to any second MTP PP tear. In females without PP tear, there were 24 second (3 mm trans average) and 43 third IS neuromas (4.1 mm trans average). In males without PP tear, there were 9 second (3.4 mm trans average) and 16 third IS neuromas (4.1 mm trans average). MTP PP tears occurred in 40% of our cases, 90% of which occurred at the second MTP. Almost all coexisted with non-neuromatous second IS lesions.

  9. Incomplete response to artificial tears is associated with features of neuropathic ocular pain.

    PubMed

    Galor, Anat; Batawi, Hatim; Felix, Elizabeth R; Margolis, Todd P; Sarantopoulos, Konstantinos D; Martin, Eden R; Levitt, Roy C

    2016-06-01

    Artificial tears are first-line therapy for patients with dry eye symptoms. It is not known, however, which patient factors associate with a positive response to therapy. The purpose of this study was to evaluate whether certain ocular and systemic findings are associated with a differential subjective response to artificial tears. Cross-sectional study of 118 individuals reporting artificial tears use (hypromellose 0.4%) to treat dry eye-associated ocular pain. An evaluation was performed to assess dry eye symptoms (via the dry eye questionnaire 5 and ocular surface disease index), ocular and systemic (non-ocular) pain complaints and ocular signs (tear osmolarity, tear breakup time, corneal staining, Schirmer testing with anaesthesia, and eyelid and meibomian gland assessment). The main outcome measures were factors associated with differential subjective response to artificial tears. By self-report, 23 patients reported no improvement, 73 partial improvement and 22 complete improvement in ocular pain with artificial tears. Patients who reported no or partial improvement in pain with artificial tears reported higher levels of hot-burning ocular pain and sensitivity to wind compared with those with complete improvement. Patients were also asked to rate the intensity of systemic pain elsewhere in the body (other than the eye). Patients who reported no or incomplete improvement with artificial tears had higher systemic pain scores compared with those with complete improvement. Both ocular and systemic (non-ocular) pain complaints are associated with a differential subjective response to artificial tears. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  10. Functional outcomes of traumatic and non-traumatic rotator cuff tears after arthroscopic repair

    PubMed Central

    Abechain, José Jorge Kitagaki; Godinho, Glaydson Gomes; Matsunaga, Fabio Teruo; Netto, Nicola Archetti; Daou, Julia Pozzetti; Tamaoki, Marcel Jun Sugawara

    2017-01-01

    AIM To compare the functional outcomes of traumatic and non-traumatic rotator cuff tears after arthroscopic repair. METHODS Eighty-seven patients with rotator cuff tears following arthroscopic treatment were divided into traumatic and non-traumatic tear groups. Postoperative muscle strength and outcomes using the modified University of California, Los Angeles score were evaluated. Sex, age, affected limb and dominant limb were correlated between groups. Muscle strength of the repaired and unaffected shoulders was compared. Rotator cuff injury size was measured. RESULTS Of the 87 patients who underwent rotator cuff repairs, 35 had traumatic tears and 52 had non-traumatic tears. In patients with non-traumatic tears, the average age was 59 years, 74.5% were female, 96.1% were right-hand dominant and 92.3% had their dominant shoulder affected. Patients with traumatic tears were 59.5 years old on average, 51.4% were female, 91.4% were right-hand dominant and 88.5% had their dominant shoulder affected. No difference existed in the mean modified University of California, Los Angeles score between patients with traumatic tears (33.7) compared with those with non-traumatic tears (32.8). No strength differences were observed between groups: The strength difference between the non-affected and affected sides was 1.21 kg in the non-traumatic group and 1.39 kg in the traumatic group (P = 0.576), while the strength ratio between the non-affected/affected sides was 0.805 in the non-traumatic group and 0.729 in the traumatic group (P = 0.224). CONCLUSION The functional results of traumatic rotator cuff repairs are similar to non-traumatic tears. Both outcomes are satisfactory. PMID:28875129

  11. Trace elements and diabetes: Assessment of levels in tears and serum.

    PubMed

    Cancarini, A; Fostinelli, J; Napoli, L; Gilberti, M E; Apostoli, P; Semeraro, F

    2017-01-01

    Tear film is critical for the well-being and homeostasis of the ocular surface. Although the composition of the tear film is well known, the composition of metallic elements have yet to be analysed. Despite trace elements metabolism has been reported to play a role in the pathogenesis of diabetes mellitus, a metabolic disease that affects several aspects of homeostasis, little is known in the literature regarding concentration and possible variation of metallic elements in tear film. We studied the concentrations of several essential and non-essential metallic elements in the tear fluid and serum of patients with type II diabetes mellitus and a group of non-diabetic controls. Serum and tear fluid were collected from 97 patients: 47 type II diabetic patients and 50 non-diabetic controls. Regarding tear film, there were statistically significant differences in Zinc, Chrome, Cobalt, Manganese, Barium, and Lead between groups; the values of all metallic elements were found to be statistically significant higher in patients with mellitus type II diabetes. Regarding serum values there was a statistically significant difference in Chrome, Cobalt, and Selenium values; the concentrations of Chrome and Cobalt were higher in the control group, while Selenium concentration was higher in diabetic patients. In patients with type II diabetes, metal elements with higher concentrations in tears compared to serum were: Lead, Barium, Manganese, Cobalt, and Chrome. In the control group, the metal elements with the highest concentration in tear film compared to serum were Chrome, Manganese, Barium, and Lead. In this study, we attempted to evaluate the possible effect of a disease, such as diabetes, on the metabolism of metallic elements. Although our evidence was very interesting, it is probably limited in its accuracy due to the fact that individuals in the control group harboured ocular pathologies. This work lays the foundation for future studies. Copyright © 2016 Elsevier Ltd. All

  12. Does the Rotator Cuff Tear Pattern Influence Clinical Outcomes After Surgical Repair?

    PubMed Central

    Watson, Scott; Allen, Benjamin; Robbins, Chris; Bedi, Asheesh; Gagnier, Joel J.; Miller, Bruce

    2018-01-01

    Background: Limited literature exists regarding the influence of rotator cuff tear morphology on patient outcomes. Purpose: To determine the effect of rotator cuff tear pattern (crescent, U-shape, L-shape) on patient-reported outcomes after rotator cuff repair. Study Design: Cohort study; Level of evidence, 3. Methods: Patients undergoing arthroscopic repair of known full-thickness rotator cuff tears were observed prospectively at regular intervals from baseline to 1 year. The tear pattern was classified at the time of surgery as crescent, U-shaped, or L-shaped. Primary outcome measures were the Western Ontario Rotator Cuff Index (WORC), the American Shoulder and Elbow Surgeons (ASES), and a visual analog scale (VAS) for pain. The tear pattern was evaluated as the primary predictor while controlling for variables known to affect rotator cuff outcomes. Mixed-methods regression and analysis of variance (ANOVA) were used to examine the effects of tear morphology on patient-reported outcomes after surgical repair from baseline to 1 year. Results: A total of 82 patients were included in the study (53 male, 29 female; mean age, 58 years [range, 41-75 years]). A crescent shape was the most common tear pattern (54%), followed by U-shaped (25%) and L-shaped tears (21%). There were no significant differences in outcome scores between the 3 groups at baseline. All 3 groups showed statistically significant improvement from baseline to 1 year, but analysis failed to show any predictive effect in the change in outcome scores from baseline to 1 year for the WORC, ASES, or VAS when tear pattern was the primary predictor. Further ANOVA also failed to show any significant difference in the change in outcome scores from baseline to 1 year for the WORC (P = .96), ASES (P = .71), or VAS (P = .86). Conclusion: Rotator cuff tear pattern is not a predictor of functional outcomes after arthroscopic rotator cuff repair. PMID:29623283

  13. Examination of in vivo tear film stability after eye blink and eye drying

    NASA Astrophysics Data System (ADS)

    Szczesna, Dorota H.; Kulas, Zbigniew; Kasprzak, Henryk T.; Stenevi, Ulf

    2007-07-01

    The purpose of this study is to investigate the kinetics of precorneal tear film stabilization process after eye blink and the process of creating the break-up of the tear film layer. The tear film of patients were examined in vivo by used the lateral shearing interferometer. The information about the distribution and stability of the tear film over the cornea is carried by the wave front reflected from the surface of tears and coded in interference fringes. Smooth and regular fringes indicate the smooth surface of tears over the cornea. Immediately after eye blink the interference fringes are observed on background of bright and dark areas. The contrast of this structure fades with time slowly and after 1-3 sec the background of interference fringes becomes uniform. The vertical orientation and instability of this structure suggests connection with eyelid movement and the spread of tears. If the eye is kept open for a long time, bright lines appear in the background of fringes after a dozen seconds. The slowly appearing structure might signify the tear film break-up. In case of eyes after a LASIK surgery the shape of the background structure has different nature and might be stable in time suggesting the stability of the corneal surface irregularities.

  14. Biomechanical Cadaveric Evaluation of Partial Acute Peroneal Tendon Tears.

    PubMed

    Wagner, Emilio; Wagner, Pablo; Ortiz, Cristian; Radkievich, Ruben; Palma, Felipe; Guzmán-Venegas, Rodrigo

    2018-06-01

    No clear guideline or solid evidence exists for peroneal tendon tears to determine when to repair, resect, or perform a tenodesis on the damaged tendon. The objective of this study was to analyze the mechanical behavior of cadaveric peroneal tendons artificially damaged and tested in a cyclic and failure mode. The hypothesis was that no failure would be observed in the cyclic phase. Eight cadaveric long leg specimens were tested on a specially designed frame. A longitudinal full thickness tendon defect was created, 3 cm in length, behind the tip of the fibula, compromising 66% of the visible width of the peroneal tendons. Cyclic testing was initially performed between 50 and 200 N, followed by a load-to-failure test. Tendon elongation and load to rupture were measured. No tendon failed or lengthened during cyclic testing. The mean load to failure for peroneus brevis was 416 N (95% confidence interval, 351-481 N) and for the peroneus longus was 723 N (95% confidence interval, 578-868 N). All failures were at the level of the defect created. In a cadaveric model of peroneal tendon tears, 33% of remaining peroneal tendon could resist high tensile forces, above the physiologic threshold. Some peroneal tendon tears can be treated conservatively without risking spontaneous ruptures. When surgically treating a symptomatic peroneal tendon tear, increased efforts may be undertaken to repair tears previously considered irreparable.

  15. A Non-surgical Intervention for Triangular Fibrocartilage Complex Tears.

    PubMed

    Barlow, Susan J

    2016-12-01

    The current literature contains no reports of treatment options other than surgery following failed conservative management of a triangular fibrocartilage complex (TFCC) tear. The purpose of this study is to describe the use of a novel brace as a non-surgical intervention for TFCC tears. This paper is a case study of a subject with a magnetic resonance imaging-confirmed TFCC tear. As an alternative to surgery, he consented to wear a novel brace for 12 weeks after conservative management of his injury had failed. His recovery from injury was monitored with a weight-bearing tolerance test and the disabilities of the arm, shoulder and hand (DASH) outcome measure. An increase in weight-bearing tolerance and upper extremity use was evident immediately after donning the brace. After 12 weeks, the subject demonstrated a return to normal weight-bearing tolerance and normal DASH outcome measure scores. These improvements were still evident at a 1-year follow-up appointment. Utilizing this novel brace resulted in functional status improvement in a subject with a TFCC tear as demonstrated by significant changes in his DASH outcome measure scores. This case study demonstrates the first non-surgical alternative treatment for a TFCC tear after conservative management has failed. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  16. Tear fluid collection in dogs and cats using ophthalmic sponges.

    PubMed

    Sebbag, Lionel; Harrington, Danielle M; Mochel, Jonathan P

    2018-05-01

    To compare the use of two ophthalmic sponges for tear collection in dogs and cats. Ten healthy dogs and 10 healthy cats. A strip (4 × 10 mm) of either cellulose or polyvinyl acetal (PVA) sponge was inserted into the ventral fornix of each eye for either 15, 30, or 60 s. The wetted strip was placed into a 0.2-mL tube that was first punctured at its bottom. Tears were eluted through the drainage hole into a 1.5-mL tube via centrifugation. Tear volume absorbed (VA) and tear volume recovered (VR) were calculated as the difference of the post- and precollection weight of the 0.2-mL tube and 1.5-mL tube, respectively. Recovery ratio (RR) was determined as the ratio between VR and VA. Ophthalmic sponges were well tolerated by all subjects. In dogs and cats, median (95% range) VA, VR, and RR were as follows: 44 μL (11-106 μL) and 16 μL (2-43 μL); 27 μL (1-84 μL) and 6 μL (0-29 μL); 64% (7-91%) and 35% (0-86%), respectively. PVA sponges achieved significantly greater VR in cats and RR in both species. All parameters were significantly greater with a collection time of 60 vs. 30 and 15 s. Body weight was associated with VA and VR in dogs but not cats. Polyvinyl acetal is better than cellulose for tear collection given its superior recovery. Ophthalmic sponges could facilitate routine analysis of tear fluid in dogs and cats, although further studies are needed to evaluate the quality of tears obtained with this method. © 2017 American College of Veterinary Ophthalmologists.

  17. Nonlinear dynamic failure process of tunnel-fault system in response to strong seismic event

    NASA Astrophysics Data System (ADS)

    Yang, Zhihua; Lan, Hengxing; Zhang, Yongshuang; Gao, Xing; Li, Langping

    2013-03-01

    Strong earthquakes and faults have significant effect on the stability capability of underground tunnel structures. This study used a 3-Dimensional Discrete Element model and the real records of ground motion in the Wenchuan earthquake to investigate the dynamic response of tunnel-fault system. The typical tunnel-fault system was composed of one planned railway tunnel and one seismically active fault. The discrete numerical model was prudentially calibrated by means of the comparison between the field survey and numerical results of ground motion. It was then used to examine the detailed quantitative information on the dynamic response characteristics of tunnel-fault system, including stress distribution, strain, vibration velocity and tunnel failure process. The intensive tunnel-fault interaction during seismic loading induces the dramatic stress redistribution and stress concentration in the intersection of tunnel and fault. The tunnel-fault system behavior is characterized by the complicated nonlinear dynamic failure process in response to a real strong seismic event. It can be qualitatively divided into 5 main stages in terms of its stress, strain and rupturing behaviors: (1) strain localization, (2) rupture initiation, (3) rupture acceleration, (4) spontaneous rupture growth and (5) stabilization. This study provides the insight into the further stability estimation of underground tunnel structures under the combined effect of strong earthquakes and faults.

  18. Fault Tree Analysis for an Inspection Robot in a Nuclear Power Plant

    NASA Astrophysics Data System (ADS)

    Ferguson, Thomas A.; Lu, Lixuan

    2017-09-01

    The life extension of current nuclear reactors has led to an increasing demand on inspection and maintenance of critical reactor components that are too expensive to replace. To reduce the exposure dosage to workers, robotics have become an attractive alternative as a preventative safety tool in nuclear power plants. It is crucial to understand the reliability of these robots in order to increase the veracity and confidence of their results. This study presents the Fault Tree (FT) analysis to a coolant outlet piper snake-arm inspection robot in a nuclear power plant. Fault trees were constructed for a qualitative analysis to determine the reliability of the robot. Insight on the applicability of fault tree methods for inspection robotics in the nuclear industry is gained through this investigation.

  19. Use of tear ring permits repair of sealed module circuitry

    NASA Technical Reports Server (NTRS)

    1965-01-01

    Improved packaging technique for modular electronic circuitry utilizes a tear ring which may be removed for repair and resealed. The tear ring is put over the container and header to which the electronic circuit assembly has been attached.

  20. Tears from children with chronic hepatitis B virus (HBV) infection are infectious vehicles of HBV transmission: experimental transmission of HBV by tears, using mice with chimeric human livers.

    PubMed

    Komatsu, Haruki; Inui, Ayano; Sogo, Tsuyoshi; Tateno, Akihiko; Shimokawa, Reiko; Fujisawa, Tomoo

    2012-08-15

    Body fluids such as saliva, urine, sweat, and tears from hepatitis B virus (HBV) carriers are potential sources of HBV transmission. Thirty-nine children and 8 adults who were chronically infected with HBV were enrolled. Real-time polymerase chain reaction was used for the quantification of HBV DNA. HBV DNA was detected in 73.7% of urine samples (14 of 19), 86.8% of saliva samples (33 of 38), 100% of tear samples (11 of 11), and 100% of sweat samples (9 of 9). Mean HBV DNA levels (±SD) in urine, saliva, tears, and sweat were 4.3 ± 1.1 log copies/mL, 5.9 ± 1.2 log copies/mL, 6.2 ± 0.7 log copies/mL, and 5.2 ± 0.6 log copies/mL, respectively. A statistically significant correlation was observed between the HBV DNA level in serum specimens and HBV DNA levels in saliva and tear specimens (r = 0.88; P < .001). Tear specimens from a child were injected intravenously into 2 human hepatocyte-transplanted chimeric mice. One week after inoculation, both chimeric mice had serum positive for HBV DNA. The levels of HBV DNA in tear specimens from young children were high. Tears were confirmed to be infectious, using chimeric mice. Strict precautions should be taken against direct contact with body fluids from HBV carriers with high-level viremia.

  1. Chondral Injuries and Irreparable Meniscal Tears Among Adolescents With Anterior Cruciate Ligament or Meniscal Tears Are More Common in Patients With Public Insurance.

    PubMed

    Williams, Ariel A; Mancini, Nickolas S; Solomito, Matthew J; Nissen, Carl W; Milewski, Matthew D

    2017-07-01

    Access to health care services is a critical component of health care reform and may differ among patients with different types of insurance. Hypothesis/Purpose: The purpose was to compare adolescents with private and public insurance undergoing surgery for anterior cruciate ligament (ACL) and/or meniscal tears. We hypothesized that patients with public insurance would have a delayed presentation from the time of injury and therefore would have a higher incidence of chondral injuries and irreparable meniscal tears and lower preoperative International Knee Documentation Committee (IKDC) scores than patients with private insurance. Cross-sectional study; Level of evidence, 3. This was a retrospective study of patients under 21 years of age undergoing ACL reconstruction and/or meniscal repair or debridement from January 2013 to March 2016 at a single pediatric sports medicine center. Patients were identified by a search of Current Procedural Terminology (CPT) codes. A chart review was performed for insurance type; preoperative diagnosis; date of injury, initial office visit, and surgery; preoperative IKDC score; intraoperative findings; and procedures. The study group consisted of 119 patients (mean age, 15.0 ± 1.7 years). Forty-one percent of patients had private insurance, while 59% had public insurance. There were 27 patients with isolated meniscal tears, 59 with combined meniscal and ACL tears, and 33 with isolated ACL tears. The mean time from injury to presentation was 56 days (range, 0-457 days) in patients with private insurance and 136 days (range, 0-1120 days) in patients with public insurance ( P = .02). Surgery occurred, on average, 35 days after the initial office visit in both groups. The mean preoperative IKDC score was 53 in both groups. Patients with meniscal tears with public insurance were more likely to require meniscal debridement than patients with private insurance (risk ratio [RR], 2.3; 95% CI, 1.7-3.1; P = .02). Patients with public insurance

  2. Dynamic ruptures on faults of complex geometry: insights from numerical simulations, from large-scale curvature to small-scale fractal roughness

    NASA Astrophysics Data System (ADS)

    Ulrich, T.; Gabriel, A. A.

    2016-12-01

    The geometry of faults is subject to a large degree of uncertainty. As buried structures being not directly observable, their complex shapes may only be inferred from surface traces, if available, or through geophysical methods, such as reflection seismology. As a consequence, most studies aiming at assessing the potential hazard of faults rely on idealized fault models, based on observable large-scale features. Yet, real faults are known to be wavy at all scales, their geometric features presenting similar statistical properties from the micro to the regional scale. The influence of roughness on the earthquake rupture process is currently a driving topic in the computational seismology community. From the numerical point of view, rough faults problems are challenging problems that require optimized codes able to run efficiently on high-performance computing infrastructure and simultaneously handle complex geometries. Physically, simulated ruptures hosted by rough faults appear to be much closer to source models inverted from observation in terms of complexity. Incorporating fault geometry on all scales may thus be crucial to model realistic earthquake source processes and to estimate more accurately seismic hazard. In this study, we use the software package SeisSol, based on an ADER-Discontinuous Galerkin scheme, to run our numerical simulations. SeisSol allows solving the spontaneous dynamic earthquake rupture problem and the wave propagation problem with high-order accuracy in space and time efficiently on large-scale machines. In this study, the influence of fault roughness on dynamic rupture style (e.g. onset of supershear transition, rupture front coherence, propagation of self-healing pulses, etc) at different length scales is investigated by analyzing ruptures on faults of varying roughness spectral content. In particular, we investigate the existence of a minimum roughness length scale in terms of rupture inherent length scales below which the rupture

  3. Fault segmentation and fluid flow in the Geneva Basin (France & Switzerland)

    NASA Astrophysics Data System (ADS)

    Cardello, Giovanni Luca; Lupi, Matteo; Makhloufi, Yasin; Do Couto, Damien; Clerc, Nicolas; Sartori, Mario; Samankassou, Elias; Moscariello, Andrea; Gorin, Georges; Meyer, Michel

    2017-04-01

    The Geneva Basin (GB) is an Oligo-Miocene siliciclastic basin tightened between the Alps and the southern Jura fold-and-thrust belt, whose carbonate reservoir is crossed by faults of uncertain continuity. In the frame of the geothermal exploration of the GB, the associated side risks, i.e., maximum expected earthquake magnitude, and the best suitable geothermal structures need to be determined. The outcropping relieves represent good field analogues of buried structures identified after seismo-stratigraphic analysis. In this frame, we review the regional tectonics to define the i) present-day setting, ii) fault properties and; iii) preferential paths for fluid flow. Field and geophysical data confirmed that during the late Oligocene-early Miocene the Molasse siliciclastic deposits progressively sealed the growing anticlines consisting of Mesozoic carbonates. Those are shaped by a series of fore- and back-thrusts, which we have identified also within the Molasse. As shortening is accommodated by bed-to-bed flexural-slip within shale-rich interlayers, usually having scarce hydraulic inter-connectivity, syn-kinematic mineralization massively concentrates instead within two strike-slip sets. The "wet" faults can be distinguished on the base of: orientation, amount of displacement and fabric. The first set (1) is constituted by left-lateral NNW-striking faults. The most remarkable of those, the Vuache Fault, is about 20 km long, determining a pop-up structure plunging to the SE. Minor structures, up to 5 km long, are the tear-faults dissecting the Salève antiform. In places, those are associated with brittle-ductile transition textures and crack-and-seal mineralization. Set (1) later evolved into discrete and still segmented faulting as it is traced by earthquakes nucleated at less than 5 km of depth (ML 5.3, Epagny 1996). The second set (2) is constituted by W/NW-striking right-lateral faults, up to 10 km long, associated in places with thick polyphase breccia

  4. Fault Deformation and Segmentation of the Newport-Inglewood Rose Canyon, and San Onofre Trend Fault Systems from New High-Resolution 3D Seismic Imagery

    NASA Astrophysics Data System (ADS)

    Holmes, J. J.; Driscoll, N. W.; Kent, G. M.

    2016-12-01

    The Inner California Borderlands (ICB) is situated off the coast of southern California and northern Baja. The structural and geomorphic characteristics of the area record a middle Oligocene transition from subduction to microplate capture along the California coast. Marine stratigraphic evidence shows large-scale extension and rotation overprinted by modern strike-slip deformation. Geodetic and geologic observations indicate that approximately 6-8 mm/yr of Pacific-North American relative plate motion is accommodated by offshore strike-slip faulting in the ICB. The farthest inshore fault system, the Newport-Inglewood Rose Canyon (NIRC) Fault is a dextral strike-slip system that is primarily offshore for approximately 120 km from San Diego to the San Joaquin Hills near Newport Beach, California. Based on trenching and well data, the NIRC Fault Holocene slip rate is 1.5-2.0 mm/yr to the south and 0.5-1.0 mm/yr along its northern extent. An earthquake rupturing the entire length of the system could produce an Mw 7.0 earthquake or larger. West of the main segments of the NIRC Fault is the San Onofre Trend (SOT) along the continental slope. Previous work concluded that this is part of a strike-slip system that eventually merges with the NIRC Fault. Others have interpreted this system as deformation associated with the Oceanside Blind Thrust fault purported to underlie most of the region. In late 2013, we acquired the first high-resolution 3D Parallel Cable (P-Cable) seismic surveys of the NIRC and SOT faults as part of the Southern California Regional Fault Mapping project aboard the R/V New Horizon. Analysis of these data volumes provides important new insights and constraints on the fault segmentation and transfer of deformation. Based on this new data, we've mapped several small fault strands associated with the SOT that appear to link up with a westward jog in right-lateral fault splays of the NIRC Fault on the shelf and then narrowly radiate southwards. Our

  5. Metasomatism, Fluid Overpressure and Brecciation at the Slab-Mantle Interface: Insights from the Livingstone Fault, New Zealand

    NASA Astrophysics Data System (ADS)

    Tarling, M.; Smith, S. A. F.; Scott, J.

    2017-12-01

    Juxtaposition of mantle peridotite and serpentinite against quartzofeldspathic and mafic schists occurs along the shallow slab-mantle interface in some subduction zones. This part of the subduction interface has been invoked as a possible source region of episodic tremor and slow slip, yet geological observations of fault zone structures and chemical reactions pertinent to this region are quite rare. The >1000 km long Livingstone Fault in New Zealand is a superbly exposed fault zone that provides a suitable analogue (both in terms of scale and the rock types involved) for the shallow slab-mantle interface. The fault is characterized by a foliated and highly sheared serpentinite mélange tens to several hundreds of meters wide that separates (partially serpentinised) peridotites from quartzofeldspathic schists. Talc- and tremolite-forming metasomatic reactions occurred along the margins of the mélange and around entrained pods due to mixing of serpentinite with silica- and calcium-rich fluids derived from the adjacent quartzofeldspathic schist. The metasomatic reactions generated significant volumes of water at the melange-schist contact that became trapped between the two relatively impermeable fault zone lithologies. On the schist side of the contact, brittle faulting was promoted by the formation of a laterally-continuous silicified zone up to tens of metres wide. On the melange side, a zone up to tens of metres wide of `crackle-breccias' containing veined stockworks of tremolite indicates periodic increases of pore pressure sufficient to cause hydraulic fracture of serpentinite. The crackle-breccias are multi-generational indicating that this process was episodic. Sr and Nd isotope data and permeability calculations suggest that the episodic brecciation process was critical to the transfer of fluids across the melange. Our observations suggest that fluid-producing metasomatic reactions along the shallow slab-mantle interface may contribute to the tremor signal

  6. Biophysical characterization of monofilm model systems composed of selected tear film phospholipids.

    PubMed

    Patterson, Matthew; Vogel, Hans J; Prenner, Elmar J

    2016-02-01

    The tear film protects the eye from foreign particles and pathogens, prevents excess evaporation, provides lubrication, and maintains a high quality optical surface necessary for vision. The anterior layer of tear film consists of polar and non-polar lipid layers. The polar lipids form a monolayer on the aqueous subphase, acting as surfactants for the non-polar lipid multilayer. A tear film polar lipid biomimetic consisting of dipalmitoyl phosphatidylcholine (DPPC), dipalmitoyl phosphatidylethanolamine (DPPE), palmitoyl glucosylceramide (PGC), and palmitoyl sphingomyelin (PSM) was characterized using Langmuir monolayers and Brewster angle microscopy (BAM). Lipid combinations formed very stable monolayers, especially those containing DPPC or PSM. Surface experiments and elasticity analyses revealed that PGC resulted in more condensed and rigid mixed monolayers. DPPE provided resistance to large changes in lipid ordering over a wide surface pressure range. Ternary mixtures containing DPPE and PGC with either DPPC or PSM experienced the greatest lipid ordering within the natural tear film surface pressure range suggesting that these lipids are important to maintain tear film integrity during the inter-blink period. Finally, BAM images revealed unique structures within monolayers of DPPC, DPPE, and PGC at the natural tear film surface pressure. 3D analysis of these domains suggested either the formation of multilayers or outward protrusions at surface pressures far below the point of irreversible collapse as seen on the isotherm. This entails that the polar lipids of tear film may be capable of multilayer formation or outward folding as a mechanism to prevent rupture of the tear film during a blink. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Cytokine and chemokine levels in tears from healthy subjects.

    PubMed

    Carreño, Ester; Enríquez-de-Salamanca, Amalia; Tesón, Marisa; García-Vázquez, Carmen; Stern, Michael E; Whitcup, Scott M; Calonge, Margarita

    2010-11-01

    There is growing evidence for the existence of an 'immune tone' in normal tears. The aim of this study was to determine the levels of a large panel of cytokines and chemokines in tears obtained from healthy subjects. These levels can then serve as baseline values for comparison with patients suffering from ocular surface diseases. Nine healthy subjects participated in this study, and normal ocular surface health was documented by the results of a dry eye questionnaire, Schirmer strip wetting, and vital staining of the cornea. Four microliters of tears were collected from each eye and analysed separately with multiplex bead-based assays for the concentration of 30 cytokines and chemokines. Twenty-five cytokines/chemokines were detected. CCL11/Eotaxin1, GM-CSF, G-CSF, IFN-γ, IL-2, IL-3, IL-4, IL-5, IL-10, IL-13, IL-12p70, IL-15, CX3CL1/Fractalkine, TNF-α, epidermal growth factor, and CCL4/MIP-1β were present at 5-100 pg/ml. IL-1β, IL-6, IL-7A, CXCL8/IL-8, and CCL2/MCP-1 were present at 100-400 pg/ml. IL-1Ra, CXCL10/IP-10 and vascular endothelial growth factor were present at more than 1000 pg/ml. Multiplex bead-based assays are convenient for cytokine/chemokine detection in tears. Fracktalkine has been detected in human healthy tears for the first time. The knowledge of cytokine/chemokine concentrations in tears from normal subjects is an important reference for further comparison with patients suffering from ocular surface diseases. Variability in their levels can reflect a phenomenon of potential importance for the understanding of the ocular surface cytokine pattern. © 2010 The Authors. Journal compilation © 2010 Acta Ophthalmol.

  8. The Effect of Ambient Ozone on Unsaturated Tear Film Wax Esters.

    PubMed

    Paananen, Riku O; Rantamäki, Antti H; Parshintsev, Jevgeni; Holopainen, Juha M

    2015-12-01

    Tear film lipid layer (TFLL) is constantly exposed to reactive ozone in the surrounding air, which may have detrimental effects on ocular health. Behenyl oleate (BO), a representative tear film wax ester, was used to study the reaction with ozone at the air-water interface. Time-dependent changes in mean molecular area of BO monolayers were measured at different ozone concentrations and surface pressures. In addition, the effect of ascorbic acid on the reaction rate was determined. Reaction was followed using thin-layer chromatography and reaction products were identified using liquid chromatography-electrospray ionization mass spectrometry (LC-MS). Tear fluid samples from healthy subjects were analyzed with LC-MS for any ozonolysis reaction products. Behenyl oleate was found to undergo rapid ozonolysis at the air-water interface at normal indoor ozone concentrations. The reaction was observed as an initial expansion followed by a contraction of the film area. Ascorbic acid was found to decrease the rate of ozonolysis. Main reaction products were identified as behenyl 9-oxononanoate and behenyl 8-(5-octyl-1,2,4-trioxolan-3-yl)octanoate. Similar ozonolysis products were not detected in the tear fluid samples. At the air-water interface, unsaturated wax esters react readily with ozone in ambient air. However, no signs of ozonolysis products were found in the tear fluid. This is most likely due to the antioxidant systems present in tear fluid. Last, the results show that ozonolysis needs to be controlled in future surface chemistry studies on tear film lipids.

  9. Active Deformation along the Southern End of the Tosco-Abreojos Fault System: New Insights from Multibeam Swath Bathymetry

    NASA Astrophysics Data System (ADS)

    Michaud, François; Calmus, Thierry; Ratzov, Gueorgui; Royer, Jean-Yves; Sosson, Marc; Bigot-Cormier, Florence; Bandy, William; Mortera Gutiérrez, Carlos

    2011-08-01

    The relative motion of the Pacific plate with respect to the North America plate is partitioned between transcurrent faults located along the western margin of Baja California and transform faults and spreading ridges in the Gulf of California. However, the amount of right lateral offset along the Baja California western margin is still debated. We revisited multibeam swath bathymetry data along the southern end of the Tosco-Abreojos fault system. In this area the depths are less than 1,000 m and allow a finer gridding at 60 m cell spacing. This improved resolution unveils several transcurrent right lateral faults offsetting the seafloor and canyons, which can be used as markers to quantify local offsets. The seafloor of the southern end of the Tosco-Abreojos fault system (south of 24°N) displays NW-SE elongated bathymetric highs and lows, suggesting a transtensional tectonic regime associated with the formation of pull-apart basins. In such an active tectonic context, submarine canyon networks are unstable. Using the deformation rate inferred from kinematic predictions and pull-apart geometry, we suggest a minimum age for the reorganization of the canyon network.

  10. Magnetic resonance imaging evidence of meniscal extrusion in medial meniscus posterior root tear.

    PubMed

    Choi, Chul-Jun; Choi, Yun-Jin; Lee, Jae-Jeong; Choi, Chong-Hyuk

    2010-12-01

    The purpose of this study was to evaluate the relation between meniscal extrusion on magnetic resonance imaging (MRI) and tearing of the posterior root of the medial meniscus, as well as to understand the relation between meniscal extrusion and chondral lesions. From January 2007 to December 2008, 387 consecutive cases of medial meniscal tears were treated arthroscopically. Of these cases, 248 (64.1%) with MRI were reviewed. Arthroscopic findings were reviewed for the type of tear and medial compartment cartilage lesion. Root tear was defined as a radial tear in the posterior horn of the medial meniscus near the tibial spine (i.e., within 5 mm of the root attachment). An MRI scan of the knee was used to evaluate the presence and extent of meniscal extrusion. Meniscal extrusion of 3 mm or greater was considered pathologic. Arthroscopic findings were compared with respect to the extent of meniscal extrusion. There were 98 male patients and 150 female patients. The mean age was 53.5 years (range, 15 to 81 years). The results showed 127 cases (51.2%) in which the medial meniscus had meniscal extrusion of 3 mm or greater. Posterior root tears were found in 66 (26.6%) of the 248 knees. The mean meniscal extrusion in patients with root tear was 3.8 ± 1.4 mm, whereas the mean extrusion of those who had no root tear was 2.7 ± 1.3 mm. We found an association between pathologic meniscal extrusion and root tear (P < .001). Meniscal extrusion showed a low positive predictive value (39%) and specificity (58%) with regard to the meniscal root tear. Meniscal extrusion was also significantly correlated with severity of chondral lesions (P < .001). Considerable extrusion (≥3 mm) can be associated with tearing of the medial meniscus root and chondral lesion of the medial femoral condyle. Level IV, therapeutic case series. Copyright © 2010 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  11. Tear thinning time and topical anesthesia as assessed using the HIRCAL grid and the NCCA.

    PubMed

    Blades, K J; Murphy, P J; Patel, S

    1999-03-01

    The literature contains conflicting reports of the effects of topical anesthetics on tear film stability, with some consensus that unpreserved topical anesthetics are less likely to reduce tear film stability than preserved preparations. This experiment investigated the effect of unpreserved 0.4% benoxinate hydrochloride on tear thinning time (TTT), in parallel with "real time" corneal sensitivity assessment. Tear film stability was assessed (HIRCAL grid) in parallel with real time assessment of the pharmacological activity (NCCA) of unpreserved 0.4% benoxinate hydrochloride in normal eyes. The anesthetic used did not significantly affect tear film stability. This finding is in agreement with previous investigators. Unpreserved 0.4% benoxinate hydrochloride could be used to facilitate tear film stability assessment. The experimental protocol used could also be applied to investigate the temporal relationship between anesthesia and tear film stability with preserved topical anesthetics that have been found to decrease tear film stability.

  12. Slip on Ridge Transform Faults: Insights From Earthquakes and Laboratory Experiments

    DTIC Science & Technology

    2005-06-01

    the volume of continental crust [Turcotte, release reported by the CMT catalog for each RTF. The1986; Aviles et al., 1987; King et al., 1988; Hirata...faults, Teconophyslcs, 118, 313-327. 30(12), 1618, doi:10.1029/2002GL016454. King , G. C. P., R. S. Stein, and J. B. Rundle (1988), The growth of Fnrncis...with temperatures of T < 600’C. Mylonites collected from the Shaka fracture zone on the South West Indian Ridge provide additional evidence for

  13. Posterior Root Meniscal Tears: Preoperative, Intraoperative, and Postoperative Imaging for Transtibial Pullout Repair.

    PubMed

    Palisch, Andrew R; Winters, Ronald R; Willis, Marc H; Bray, Collin D; Shybut, Theodore B

    2016-10-01

    The menisci play an important biomechanical role in axial load distribution of the knees by means of hoop strength, which is contingent on intact circumferentially oriented collagen fibers and meniscal root attachments. Disruption of the meniscal root attachments leads to altered biomechanics, resulting in progressive cartilage loss, osteoarthritis, and subchondral edema, with the potential for development of a subchondral insufficiency fracture. Identification of meniscal root tears at magnetic resonance (MR) imaging is crucial because new arthroscopic surgical techniques (transtibial pullout repair) have been developed to repair meniscal root tears and preserve the tibiofemoral cartilage of the knee. An MR imaging classification of posterior medial meniscal root ligament lesions has been recently described that is dedicated to the posterior root of the medial meniscus. An arthroscopic classification of meniscal root tears has been described that can be applied to the anterior and posterior roots of both the medial meniscus and the lateral meniscus. This arthroscopic classification includes type 1, partial stable root tears; type 2, complete radial root tears; type 3, vertical longitudinal bucket-handle tears; type 4, complex oblique tears; and type 5, bone avulsion fractures of the root attachments. Knowledge of these classifications and the potential contraindications to meniscal root repair can aid the radiologist in the preoperative reporting of meniscal root tear types and the evaluation of the tibiofemoral cartilage. As more patients undergo arthroscopic repair of meniscal root tears, familiarity with the surgical technique and the postoperative radiographic and MR imaging appearance is important to adequately report the imaging findings. © RSNA, 2016.

  14. Treatment Strategy for Irreparable Rotator Cuff Tears

    PubMed Central

    Oh, Joo Han; Rhee, Sung Min

    2018-01-01

    Recently, patients with shoulder pain have increased rapidly. Of all shoulder disorders, rotator cuff tears (RCTs) are most prevalent in the middle-aged and older adults, which is the primary reason for shoulder surgery in the population. Some authors have reported that up to 30% of total RCTs can be classified as irreparable due to the massive tear size and severe muscle atrophy. In this review article, we provide an overview of treatment methods for irreparable massive RCTs and discuss proper surgical strategies for RCTs that require operative management. PMID:29854334

  15. The Relationship Between Intraoperative Tear Dimensions and Postoperative Pain in 1624 Consecutive Arthroscopic Rotator Cuff Repairs.

    PubMed

    Yeo, Daniel Y T; Walton, Judie R; Lam, Patrick; Murrell, George A C

    2017-03-01

    Rotator cuff repair often results in significant pain postoperatively, the cause of which is undetermined. Purpose/Hypothesis: The aim of this study was to evaluate the relationship between rotator cuff tear area and postoperative pain in patients who had undergone arthroscopic rotator cuff repair. We hypothesized that larger tears would be more painful because of elevated repair tension at 1 week postoperatively but that smaller tears would be more painful because of a greater healing response, especially from 6 weeks postoperatively. Cohort study; Level of evidence, 3. A total of 1624 patients who underwent arthroscopic rotator cuff repair were included in this study. Exclusion criteria were moderate to severe osteoarthritis, isolated subscapularis repair, calcific tendinitis, synthetic patch repair, revision surgery, and retears on ultrasound at 6 months after surgery. Rotator cuff tears were subdivided into groups based on the tear size and retear rate found for each group. A modified L'Insalata questionnaire was given before surgery and at 1 week, 6 weeks, 3 months, and 6 months after surgery. Pearson and Spearman correlation coefficient tests were performed between rotator cuff tear areas and pain scores. Intraoperative rotator cuff tear areas did not correlate with pain scores preoperatively or at 1 week after surgery. A smaller tear area was associated with more frequent and severe pain with overhead activities, at rest, and during sleep as well as a poorer perceived overall shoulder condition at 6 weeks, 3 months, and 6 months after repair ( r = 0.11-0.23, P < .0001). Patients who were younger, had partial-thickness tears, and had occupational injuries experienced more pain postoperatively ( r = 0.10-0.28, P < .0001). Larger tears did not have more pain at 1 week after surgery. The retear rate was 7% in tears <2 cm 2 but reached 44% in tears >8 cm 2 . There were fewer retears with smaller tears, but they were more painful than large tears postoperatively

  16. Spatial Patterns of Geomorphic Surface Features and Fault Morphology Based on Diffusion Equation Modeling of the Kumroch Fault Kamchatka Peninsula, Russia

    NASA Astrophysics Data System (ADS)

    Heinlein, S. N.

    2013-12-01

    Remote sensing data sets are widely used for evaluation of surface manifestations of active tectonics. This study utilizes ASTER GDEM and Landsat ETM+ data sets with Google Earth images draped over terrain models. This study evaluates 1) the surrounding surface geomorphology of the study area with these data sets and 2) the morphology of the Kumroch Fault using diffusion modeling to estimate constant diffusivity (κ) and estimate slip rates by means of real ground data measured across fault scarps by Kozhurin et al. (2006). Models of the evolution of fault scarp morphology provide time elapsed since slip initiated on a faults surface and may therefore provide more accurate estimates of slip rate than the rate calculated by dividing scarp offset by the age of the ruptured surface. Profile modeling of scarps collected by Kozhurin et al. (2006) formed by several events distributed through time and were evaluated using a constant slip rate (CSR) solution which yields a value A/κ (1/2 slip rate/diffusivity). Time elapsed since slip initiated on the fault is determined by establishing a value for κ and measuring total scarp offset. CSR nonlinear modeling estimated of κ range from 8m2/ka - 14m2/ka on the Kumroch Fault which indicates a slip rates of 0.6 mm/yr - 1.0 mm/yr since 3.4 ka -3.7 ka. This method provides a quick and inexpensive way to gather data for a regional tectonic study and establish estimated rates of tectonic activity. Analyses of the remote sensing data are providing new insight into the role of active tectonics within the region. Results from fault scarp diffusion models of Mattson and Bruhn (2001) and DuRoss and Bruhn (2004) and Kozhurin et al. (2006), Kozhurin (2007), Kozhurin et al. (2008) and Pinegina et al. 2012 trench profiles of the KF as calibrated age fault scarp diffusion rates were estimated. (-) mean that no data could be determined.

  17. Finding faults: analogical comparison supports spatial concept learning in geoscience.

    PubMed

    Jee, Benjamin D; Uttal, David H; Gentner, Dedre; Manduca, Cathy; Shipley, Thomas F; Sageman, Bradley

    2013-05-01

    A central issue in education is how to support the spatial thinking involved in learning science, technology, engineering, and mathematics (STEM). We investigated whether and how the cognitive process of analogical comparison supports learning of a basic spatial concept in geoscience, fault. Because of the high variability in the appearance of faults, it may be difficult for students to learn the category-relevant spatial structure. There is abundant evidence that comparing analogous examples can help students gain insight into important category-defining features (Gentner in Cogn Sci 34(5):752-775, 2010). Further, comparing high-similarity pairs can be especially effective at revealing key differences (Sagi et al. 2012). Across three experiments, we tested whether comparison of visually similar contrasting examples would help students learn the fault concept. Our main findings were that participants performed better at identifying faults when they (1) compared contrasting (fault/no fault) cases versus viewing each case separately (Experiment 1), (2) compared similar as opposed to dissimilar contrasting cases early in learning (Experiment 2), and (3) viewed a contrasting pair of schematic block diagrams as opposed to a single block diagram of a fault as part of an instructional text (Experiment 3). These results suggest that comparison of visually similar contrasting cases helped distinguish category-relevant from category-irrelevant features for participants. When such comparisons occurred early in learning, participants were more likely to form an accurate conceptual representation. Thus, analogical comparison of images may provide one powerful way to enhance spatial learning in geoscience and other STEM disciplines.

  18. Why the 2002 Denali fault rupture propagated onto the Totschunda fault: implications for fault branching and seismic hazards

    USGS Publications Warehouse

    Schwartz, David P.; Haeussler, Peter J.; Seitz, Gordon G.; Dawson, Timothy E.

    2012-01-01

    The propagation of the rupture of the Mw7.9 Denali fault earthquake from the central Denali fault onto the Totschunda fault has provided a basis for dynamic models of fault branching in which the angle of the regional or local prestress relative to the orientation of the main fault and branch plays a principal role in determining which fault branch is taken. GeoEarthScope LiDAR and paleoseismic data allow us to map the structure of the Denali-Totschunda fault intersection and evaluate controls of fault branching from a geological perspective. LiDAR data reveal the Denali-Totschunda fault intersection is structurally simple with the two faults directly connected. At the branch point, 227.2 km east of the 2002 epicenter, the 2002 rupture diverges southeast to become the Totschunda fault. We use paleoseismic data to propose that differences in the accumulated strain on each fault segment, which express differences in the elapsed time since the most recent event, was one important control of the branching direction. We suggest that data on event history, slip rate, paleo offsets, fault geometry and structure, and connectivity, especially on high slip rate-short recurrence interval faults, can be used to assess the likelihood of branching and its direction. Analysis of the Denali-Totschunda fault intersection has implications for evaluating the potential for a rupture to propagate across other types of fault intersections and for characterizing sources of future large earthquakes.

  19. Statistical mechanics and scaling of fault populations with increasing strain in the Corinth Rift

    NASA Astrophysics Data System (ADS)

    Michas, Georgios; Vallianatos, Filippos; Sammonds, Peter

    2015-12-01

    Scaling properties of fracture/fault systems are studied in order to characterize the mechanical properties of rocks and to provide insight into the mechanisms that govern fault growth. A comprehensive image of the fault network in the Corinth Rift, Greece, obtained through numerous field studies and marine geophysical surveys, allows for the first time such a study over the entire area of the Rift. We compile a detailed fault map of the area and analyze the scaling properties of fault trace-lengths by using a statistical mechanics model, derived in the framework of generalized statistical mechanics and associated maximum entropy principle. By using this framework, a range of asymptotic power-law to exponential-like distributions are derived that can well describe the observed scaling patterns of fault trace-lengths in the Rift. Systematic variations and in particular a transition from asymptotic power-law to exponential-like scaling are observed to be a function of increasing strain in distinct strain regimes in the Rift, providing quantitative evidence for such crustal processes in a single tectonic setting. These results indicate the organization of the fault system as a function of brittle strain in the Earth's crust and suggest there are different mechanisms for fault growth in the distinct parts of the Rift. In addition, other factors such as fault interactions and the thickness of the brittle layer affect how the fault system evolves in time. The results suggest that regional strain, fault interactions and the boundary condition of the brittle layer may control fault growth and the fault network evolution in the Corinth Rift.

  20. Active Fault Topography and Fault Outcrops in the Central Part of the Nukumi fault, the 1891 Nobi Earthquake Fault System, Central Japan

    NASA Astrophysics Data System (ADS)

    Sasaki, T.; Ueta, K.; Inoue, D.; Aoyagi, Y.; Yanagida, M.; Ichikawa, K.; Goto, N.

    2010-12-01

    It is important to evaluate the magnitude of earthquake caused by multiple active faults, taking into account the simultaneous effects. The simultaneity of adjacent active faults are often decided on the basis of geometric distances except for known these paleoseismic records. We have been studied the step area between the Nukumi fault and the Neodani fault, which appeared as consecutive ruptures in the 1891 Nobi earthquake, since 2009. The purpose of this study is to establish innovation in valuation technique of the simultaneity of adjacent active faults in addition to the paleoseismic record and the geometric distance. Geomorphological, geological and reconnaissance microearthquake surveys are concluded. The present work is intended to clarify the distribution of tectonic geomorphology along the Nukumi fault and the Neodani fault by high-resolution interpretations of airborne LiDAR DEM and aerial photograph, and the field survey of outcrops and location survey. The study area of this work is the southeastern Nukumi fault and the northwestern Neodani fault. We interpret DEM using shaded relief map and stereoscopic bird's-eye view made from 2m mesh DEM data which is obtained by airborne laser scanner of Kokusai Kogyo Co., Ltd. Aerial photographic survey is for confirmation of DEM interpretation using 1/16,000 scale photo. As a result of topographic survey, we found consecutive tectonic topography which is left lateral displacement of ridge and valley lines and reverse scarplets along the Nukumi fault and the Neodani fault . From Ogotani 2km southeastern of Nukumi pass which is located at the southeastern end of surface rupture along the Nukumi fault by previous study to Neooppa 9km southeastern of Nukumi pass, we can interpret left lateral topographies and small uphill-facing fault scarps on the terrace surface by detail DEM investigation. These topographies are unrecognized by aerial photographic survey because of heavy vegetation. We have found several new

  1. Over the counter (OTC) artificial tear drops for dry eye syndrome

    PubMed Central

    Pucker, Andrew D; Ng, Sueko M; Nichols, Jason J

    2016-01-01

    Background Over the counter (OTC) artificial tears historically have been the first line of treatment for dry eye syndrome and dry eye-related conditions like contact lens discomfort, yet currently we know little regarding the overall efficacy of individual, commercially available artificial tears. This review provides a much needed meta-analytical look at all randomized and quasi-randomized clinical trials that have analyzed head-to-head comparisons of OTC artificial tears. Objectives To evaluate the effectiveness and toxicity of OTC artificial tear applications in the treatment of dry eye syndrome compared with another class of OTC artificial tears, no treatment, or placebo. Search methods We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2015, Issue 12), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to December 2015), EMBASE (January 1980 to December 2015), Latin American and Caribbean Health Sciences (LILACS) (January 1982 to December 2015), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov), the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en) and the US Food and Drugs Administration (FDA) website (www.fda.gov). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 4 December 2015. We searched reference lists of included trials for any additional trials not identified by the electronic searches. Selection criteria This review includes randomized controlled trials with adult participants who were diagnosed with dry eye, regardless of race and gender. We included trials in which the age of participants was not reported, and clinical trials comparing OTC artificial tears with another class of OTC artificial tears, placebo, or no treatment. This review did not

  2. Preexisting Rotator Cuff Tears as a Predictor of Outcomes in National Football League Athletes.

    PubMed

    Gibbs, Daniel B; Lynch, T Sean; Gombera, M Mustafa; Saltzman, Matthew D; Nuber, Gordon W; Schroeder, Gregory D; Labelle, Mark; Hollett, Brian P

    A preexisting rotator cuff tear may affect the draft status and career performance of National Football League (NFL) players. Preexisting rotator cuff tears decrease a player's draft status, performance, and longevity in the NFL. Retrospective cohort study. Level 3. Medical reports of prospective NFL players during the NFL Scouting Combine from 2003 to 2011 were evaluated to identify players with a previous rotator cuff tear. Athletes were matched to control draftees without documented shoulder pathology by age, position, year drafted, and round drafted. Career statistics and performance scores were calculated. Between 2003 and 2011, 2965 consecutive athletes were evaluated. Forty-nine athletes had preexisting rotator cuff tears: 22 athletes underwent surgical intervention for their tear and 27 were treated nonoperatively. Those with a rotator cuff tear were significantly less likely to be drafted than those without a previous injury (55.1% vs 77.5%, P = 0.002). The 27 drafted athletes with preexisting rotator cuff tears started significantly fewer games (23.7 vs 43.0, P = 0.02) and played significantly fewer years (4.3 vs 5.7, P = 0.04) and significantly fewer games (47.1 vs 68.4, P = 0.04) than matched control athletes without rotator cuff tears. Athletes with a preexisting rotator cuff tear were less likely to be drafted and had decreased career longevity.

  3. Fracture zones constrained by neutral surfaces in a fault-related fold: Insights from the Kelasu tectonic zone, Kuqa Depression

    NASA Astrophysics Data System (ADS)

    Sun, Shuai; Hou, Guiting; Zheng, Chunfang

    2017-11-01

    Stress variation associated with folding is one of the controlling factors in the development of tectonic fractures, however, little attention has been paid to the influence of neutral surfaces during folding on fracture distribution in a fault-related fold. In this study, we take the Cretaceous Bashijiqike Formation in the Kuqa Depression as an example and analyze the distribution of tectonic fractures in fault-related folds by core observation and logging data analysis. Three fracture zones are identified in a fault-related fold: a tensile zone, a transition zone and a compressive zone, which may be constrained by two neutral surfaces of fold. Well correlation reveals that the tensile zone and the transition zone reach the maximum thickness at the fold hinge and get thinner in the fold limbs. A 2D viscoelastic stress field model of a fault-related fold was constructed to further investigate the mechanism of fracturing. Statistical and numerical analysis reveal that the tensile zone and the transition zone become thicker with decreasing interlimb angle. Stress variation associated with folding is the first level of control over the general pattern of fracture distribution while faulting is a secondary control over the development of local fractures in a fault-related fold.

  4. JBP485 promotes tear and mucin secretion in ocular surface epithelia

    PubMed Central

    Nakamura, Takahiro; Hata, Yuiko; Nagata, Maho; Yokoi, Norihiko; Yamaguchi, Shumpei; Kaku, Taiichi; Kinoshita, Shigeru

    2015-01-01

    Dry eye syndrome (DES), a multifactorial disease of the tears and ocular surface, is one of the most common ocular disorders. Tear film contains ocular mucins and is essential for maintaining the homeostasis of the wet ocular surface. Since there are a limited number of clinical options for the treatment of DES, additional novel treatments are needed to improve the clinical results. In this study, we found that placental extract-derived dipeptide (JBP485) clearly promoted the expression and secretion of gel-forming mucin 5ac (Muc5ac) in rabbit conjunctival epithelium. JBP485 also elevated the expression level of cell surface-associated mucins (Muc1/4/16) in rabbit corneal epithelium. The Schirmer tear test results indicated that JBP485 induced tear secretion in the rabbit model. Moreover, JBP485 clinically improved corneal epithelial damage in a mouse dry eye model. Thus, our data indicate that JBP485 efficiently promoted mucin and aqueous tear secretion in rabbit ocular surface epithelium and has the potential to be used as a novel treatment for DES. PMID:25996902

  5. JBP485 promotes tear and mucin secretion in ocular surface epithelia.

    PubMed

    Nakamura, Takahiro; Hata, Yuiko; Nagata, Maho; Yokoi, Norihiko; Yamaguchi, Shumpei; Kaku, Taiichi; Kinoshita, Shigeru

    2015-05-21

    Dry eye syndrome (DES), a multifactorial disease of the tears and ocular surface, is one of the most common ocular disorders. Tear film contains ocular mucins and is essential for maintaining the homeostasis of the wet ocular surface. Since there are a limited number of clinical options for the treatment of DES, additional novel treatments are needed to improve the clinical results. In this study, we found that placental extract-derived dipeptide (JBP485) clearly promoted the expression and secretion of gel-forming mucin 5ac (Muc5ac) in rabbit conjunctival epithelium. JBP485 also elevated the expression level of cell surface-associated mucins (Muc1/4/16) in rabbit corneal epithelium. The Schirmer tear test results indicated that JBP485 induced tear secretion in the rabbit model. Moreover, JBP485 clinically improved corneal epithelial damage in a mouse dry eye model. Thus, our data indicate that JBP485 efficiently promoted mucin and aqueous tear secretion in rabbit ocular surface epithelium and has the potential to be used as a novel treatment for DES.

  6. Predeployment validation of fault-tolerant systems through software-implemented fault insertion

    NASA Technical Reports Server (NTRS)

    Czeck, Edward W.; Siewiorek, Daniel P.; Segall, Zary Z.

    1989-01-01

    Fault injection-based automated testing (FIAT) environment, which can be used to experimentally characterize and evaluate distributed realtime systems under fault-free and faulted conditions is described. A survey is presented of validation methodologies. The need for fault insertion based on validation methodologies is demonstrated. The origins and models of faults, and motivation for the FIAT concept are reviewed. FIAT employs a validation methodology which builds confidence in the system through first providing a baseline of fault-free performance data and then characterizing the behavior of the system with faults present. Fault insertion is accomplished through software and allows faults or the manifestation of faults to be inserted by either seeding faults into memory or triggering error detection mechanisms. FIAT is capable of emulating a variety of fault-tolerant strategies and architectures, can monitor system activity, and can automatically orchestrate experiments involving insertion of faults. There is a common system interface which allows ease of use to decrease experiment development and run time. Fault models chosen for experiments on FIAT have generated system responses which parallel those observed in real systems under faulty conditions. These capabilities are shown by two example experiments each using a different fault-tolerance strategy.

  7. Effects of DA-6034 on aqueous tear fluid secretion and conjunctival goblet cell proliferation.

    PubMed

    Choi, Seul Min; Lee, Yeong Geon; Seo, Mi Jung; Kang, Kyung Koo; Ahn, Byoung Ok; Yoo, Moohi

    2009-06-01

    This study was conducted to evaluate the effect of DA-6034, a potent secretagogue, on aqueous tear fluid secretion and its quality in normal rabbit. We also evaluated, in animal models of experimentally induced dry eye disease, its effectiveness over time to stimulate aqueous tear production by ocular ferning test and goblet cell proliferation. Aqueous tear production, total protein levels, and glycoprotein levels in normal rabbits were evaluated after topical application of DA-6034 (0.3, 1, and 3%). Moreover, time course aqueous tear volume measurement and ocular ferning test in tear fluid were performed in dry eyes of rabbits that had been given 1% atropine sulfate, topically. Altogether, tear fluid production and conjunctival goblet cell numbers were measured in dry eyes of mice that had been given topical scopolamine. Topical application of DA-6034 (0.3, 1, and 3%) significantly increased (P < 0.05) aqueous tear production in a concentration-dependent manner in normal rabbits. There was no change in total protein levels while glycoprotein levels were significantly increased (P < 0.05) at 3% DA-6034. The increase in aqueous tear fluid was significant (P < 0.05) and lasted for 2 h post-instillation in dry eyes of rabbits that had been given 1% atropine sulfate; 10-day repeated instillation of the drug in this model resulted in large and homogeneous fern-like tear patterns. In a mouse model, DA-6034 given as a 3% eyedrop solution significantly increased (P < 0.05) tear fluid production and conjunctival goblet cell number. These results suggest that DA-6034 accelerates not only tear secretion but also mucin production and may be a potential therapeutic agent for the treatment of dry eye disease.

  8. Localized fluid discharge in subduction zones: Insights from tension veins around an ancient megasplay fault (Nobeoka Thrust, SW Japan)

    NASA Astrophysics Data System (ADS)

    Otsubo, M.; Hardebeck, J.; Miyakawa, A.; Yamaguchi, A.; Kimura, G.

    2017-12-01

    Fluid-rock interactions along seismogenic faults are of great importance to understand fault mechanics. The fluid loss by the formation of mode I cracks (tension cracks) increases the fault strength and creates drainage asperities along the plate interface (Sibson, 2013, Tectonophysics). The Nobeoka Thrust, in southwestern Japan, is an on-land example of an ancient megasplay fault and provides an excellent record of deformation and fluid flow at seismogenic depths of a subduction zone (Kondo et al., 2005, Tectonics). We focus on (1) Pore fluid pressure loss, (2) Amount of fault strength recovery, and (3) Fluid circulation by the formation of mode I cracks in the post-seismic period around the fault zone of the Nobeoka Thrust. Many quartz veins that filled mode I crack at the coastal outcrops suggest a normal faulting stress regime after faulting of the Nobeoka Thrust (Otsubo et al., 2016, Island Arc). We estimated the decrease of the pore fluid pressure by the formation of the mode I cracks around the Nobeoka Thrust in the post-seismic period. When the pore fluid pressure exceeds σ3, veins filling mode I cracks are constructed (Jolly and Sanderson, 1997, Jour. Struct. Geol.). We call the pore fluid pressure that exceeds σ3 "pore fluid over pressure". The differential stress in the post-seismic period and the driving pore fluid pressure ratio P* (P* = (Pf - σ3) / (σ1 - σ3), Pf: pore fluid pressure) are parameters to estimate the pore fluid over pressure. In the case of the Nobeoka Thrust (P* = 0.4, Otsubo et al., 2016, Island Arc), the pore fluid over pressure is up to 20 MPa (assuming tensile strength = 10 MPa). 20 MPa is equivalent to <10% of the total pore fluid pressure around the Nobeoka Thrust (depth = 10 km, density = 2.7 kg/m3). When the pore fluid pressure decreases by 4%, the normalized pore pressure ratio λ* (λ* = (Pf - Ph) / (Pl - Ph), Pl: lithostatic pressure; Ph: hydrostatic pressure) changes from 0.95 to 0.86. In the case of the Nobeoka Thrust

  9. Does the Critical Shoulder Angle Correlate With Rotator Cuff Tear Progression?

    PubMed

    Chalmers, Peter N; Salazar, Dane; Steger-May, Karen; Chamberlain, Aaron M; Yamaguchi, Ken; Keener, Jay D

    2017-06-01

    The critical shoulder angle (CSA) has been reported to be associated with rotator cuff disease and has been suggested as an etiology for cuff tears. However, it is unclear whether acromial morphologic characteristics such as CSA are a cause or effect because all studies to date have been retrospective. (1) How often can the CSA be reliably measured? (2) Is the CSA associated with rotator cuff disease? (3) Is the CSA correlated with baseline tear size or tear enlargement? (4) Does the CSA change with time? In this retrospective comparison of longitudinally collected data, patients with asymptomatic rotator cuff tears underwent ultrasonography and standardized AP radiographs at enrollment and yearly thereafter during a median of 4 years. Three hundred ninety-five patients were included, of whom 14 were excluded as they were not yet eligible for 2-year followup and 68 (18%) were lost to followup, leaving 313 study patients who were evaluated with 1433 radiographs. Patients with adhesive capsulitis with normal rotator cuffs and radiographically normal scapulae were included as control subjects (119 subjects). Two observers (PNC, DS) measured the CSA in a blinded fashion. Radiographs that met Suter-Henninger criteria for CSA measurement reliability were included. For the study group, 179 of the 313 (57%) patients with radiographs that met Suter-Henninger criteria were further analyzed; the remainder were excluded from this study. For the control group, 50 of 119 (42%) subjects met criteria and were further analyzed. Tear enlargement was found in 94 patients, and the CSA was compared in patients with tears and control subjects, and in tears with or without enlargement, and was correlated with tear size. In a subgroup of the study group in which 59 of 179 patients had a minimum of 3 years between initial and followup radiographs, two CSA measurements were performed to measure change. In total, of the 1552 radiographs evaluated, only 326 (21%) were of sufficient quality to

  10. Resonance-Based Sparse Signal Decomposition and its Application in Mechanical Fault Diagnosis: A Review.

    PubMed

    Huang, Wentao; Sun, Hongjian; Wang, Weijie

    2017-06-03

    Mechanical equipment is the heart of industry. For this reason, mechanical fault diagnosis has drawn considerable attention. In terms of the rich information hidden in fault vibration signals, the processing and analysis techniques of vibration signals have become a crucial research issue in the field of mechanical fault diagnosis. Based on the theory of sparse decomposition, Selesnick proposed a novel nonlinear signal processing method: resonance-based sparse signal decomposition (RSSD). Since being put forward, RSSD has become widely recognized, and many RSSD-based methods have been developed to guide mechanical fault diagnosis. This paper attempts to summarize and review the theoretical developments and application advances of RSSD in mechanical fault diagnosis, and to provide a more comprehensive reference for those interested in RSSD and mechanical fault diagnosis. Followed by a brief introduction of RSSD's theoretical foundation, based on different optimization directions, applications of RSSD in mechanical fault diagnosis are categorized into five aspects: original RSSD, parameter optimized RSSD, subband optimized RSSD, integrated optimized RSSD, and RSSD combined with other methods. On this basis, outstanding issues in current RSSD study are also pointed out, as well as corresponding instructional solutions. We hope this review will provide an insightful reference for researchers and readers who are interested in RSSD and mechanical fault diagnosis.

  11. Resonance-Based Sparse Signal Decomposition and Its Application in Mechanical Fault Diagnosis: A Review

    PubMed Central

    Huang, Wentao; Sun, Hongjian; Wang, Weijie

    2017-01-01

    Mechanical equipment is the heart of industry. For this reason, mechanical fault diagnosis has drawn considerable attention. In terms of the rich information hidden in fault vibration signals, the processing and analysis techniques of vibration signals have become a crucial research issue in the field of mechanical fault diagnosis. Based on the theory of sparse decomposition, Selesnick proposed a novel nonlinear signal processing method: resonance-based sparse signal decomposition (RSSD). Since being put forward, RSSD has become widely recognized, and many RSSD-based methods have been developed to guide mechanical fault diagnosis. This paper attempts to summarize and review the theoretical developments and application advances of RSSD in mechanical fault diagnosis, and to provide a more comprehensive reference for those interested in RSSD and mechanical fault diagnosis. Followed by a brief introduction of RSSD’s theoretical foundation, based on different optimization directions, applications of RSSD in mechanical fault diagnosis are categorized into five aspects: original RSSD, parameter optimized RSSD, subband optimized RSSD, integrated optimized RSSD, and RSSD combined with other methods. On this basis, outstanding issues in current RSSD study are also pointed out, as well as corresponding instructional solutions. We hope this review will provide an insightful reference for researchers and readers who are interested in RSSD and mechanical fault diagnosis. PMID:28587198

  12. Assessing tear film on soft contact lenses with lateral shearing interferometry.

    PubMed

    Szczesna, Dorota H

    2011-11-01

    Evaluating precorneal tear film is one of important clinical measurements for assessing health of anterior eye. Contact lens wear is known to influence the quality of tear film. The aim was to evaluate the applicability of lateral shearing interferometry technique in the noninvasive assessment of the effects of contact lens replacement modality and its water content on tear film stability. Sixteen regular soft contact lens wearers took place in the study. Lateral shearing interferometry measurements, in suppressed blinking conditions, were taken in the mornings and afternoons, after a minimum of 5 hours of lens wear for the daily lenses, and after 2 weeks and 1 month for the fortnightly and monthly lens replacement modalities, respectively. Significant differences (paired bootstrap-based Behrens-Fisher test, P < 0.05) in the tear film surface quality were found between all considered pairs of replacement modalities except for the daily and fortnightly lenses measured in the afternoon of the first day of wear. Significant worsening (paired bootstrap-based Behrens-Fisher test, P < 0.001) of tear film quality was found for the low water content materials. Lateral shearing interferometry is a powerful method for the noninvasive assessment of tear film surface quality on soft contact lenses that may find, in future, its use in the clinical assessment of anterior eye's health.

  13. Changes in the tear film and ocular surface from dry eye syndrome.

    PubMed

    Johnson, Michael E; Murphy, Paul J

    2004-07-01

    Dry eye syndrome (DES) refers to a spectrum of ocular surface diseases with diverse and frequently multiple aetiologies. The common feature of the various manifestations of DES is an abnormal tear film. Tear film abnormalities associated with DES are tear deficiency, owing to insufficient supply or excessive loss, and anomalous tear composition. These categorizations are artificial, as in reality both often coexist. DES disrupts the homeostasis of the tear film with its adjacent structures, and adversely affects its ability to perform essential functions such as supporting the ocular surface epithelium and preventing microbial invasion. In addition, whatever the initial trigger, moderate and severe DES is characterized by ocular surface inflammation, which in turn becomes the cause and consequence of cell damage, creating a self-perpetuating cycle of deterioration. Progress has been made in our understanding of the aetiology and pathogenesis of DES, and these advances have encouraged a proliferation of therapeutic options. This article aims to amalgamate prevailing ideas of DES development, and to assist in that, relevant aspects of the structure, function, and production of the tear film are reviewed. Additionally, a synopsis of therapeutic strategies for DES is presented, detailing treatments currently available, and those in development.

  14. Architectural and microstructural characterization of a seismogenic normal fault in dolostones (Central Apennines, Italy)

    NASA Astrophysics Data System (ADS)

    Demurtas, Matteo; Fondriest, Michele; Clemenzi, Luca; Balsamo, Fabrizio; Storti, Fabrizio; Di Toro, Giulio

    2015-04-01

    (fracture spacing > 10 cm). Other than by the main boundary normal fault, slip was accommodated in the cataclastic zone by minor sub-parallel synthetic and antithetic normal faults and by few tear strike-slip fault; the rest of the footwall shows progressively less pervasive damage down to the background intensity of deformation. High strain domains include (1) pervasively fragmented dolostones with radial fractures (evidence of in-situ shattering), (2) shiny (mirror-like) fault surfaces truncating dolostone clasts, (3) mm-thick ultra-cataclastic layers with lobate and cuspate boundaries, (4) mixed calcite-dolomite "foliated cataclasites". The above microstructures can be associated with seismic faulting. Fluids infiltration during deformation is attested by the occurrence of multiple generations of carbonate-filled veins, often exploited as minor faults with a mylonite-like fabric (e.g. presence of micrometer in size euhedral calcite grains). The attitude of the studied segment of the CIFZ, the thickness of the footwall block and the kinematics of the minor faults compares well with the hypocentral and focal mechanisms distribution typical of the earthquake sequences in the Apennines. In particular, the CIFZ can be considered as an exhumed analogue of the normal fault system that caused the L'Aquila 2009 seismic sequence.

  15. A Cooperative Approach to Virtual Machine Based Fault Injection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Naughton III, Thomas J; Engelmann, Christian; Vallee, Geoffroy R

    Resilience investigations often employ fault injection (FI) tools to study the effects of simulated errors on a target system. It is important to keep the target system under test (SUT) isolated from the controlling environment in order to maintain control of the experiement. Virtual machines (VMs) have been used to aid these investigations due to the strong isolation properties of system-level virtualization. A key challenge in fault injection tools is to gain proper insight and context about the SUT. In VM-based FI tools, this challenge of target con- text is increased due to the separation between host and guest (VM).more » We discuss an approach to VM-based FI that leverages virtual machine introspection (VMI) methods to gain insight into the target s context running within the VM. The key to this environment is the ability to provide basic information to the FI system that can be used to create a map of the target environment. We describe a proof- of-concept implementation and a demonstration of its use to introduce simulated soft errors into an iterative solver benchmark running in user-space of a guest VM.« less

  16. Assessment of tear osmolarity and other dry eye parameters in post-LASIK eyes.

    PubMed

    Hassan, Ziad; Szalai, Eszter; Berta, Andras; Modis, Laszlo; Nemeth, Gabor

    2013-07-01

    To assess the tear osmolarity using the TearLab device after laser in situ keratomileusis (LASIK) and to compare the values with those obtained by traditional tear film tests before and after the procedure. Thirty eyes of 15 refractive surgery candidates (5 men and 10 women of mean age: 30.55 ± 11.79 years) were examined. Using a special questionnaire (Ocular Surface Disease Index), subjective dry eye complaints were evaluated, and then, the tear osmolarity was measured with the TearLab system (TearLab Corporation) and conventional dry eye tests were carried out. Examinations were performed preoperatively and at 1, 30, and 60 days after the surgery. The mean value of tear osmolarity was 303.62 ± 12.29 mOsm/L before the surgery and 303.58 ± 20.14 mOsm/L at 60 days after the treatment (P = 0.69). Mean lid parallel conjunctival folds value was 0.68 ± 0.68 before the procedure and 0.58 ± 0.65 subsequent to surgery (P = 0.25). Meibomian gland dysfunction was not detected. No significant deviation was observed in the values of Schirmer test, corneal staining, tear break-up time, and lid parallel conjunctival folds when compared with postoperatively obtained values during the follow-up period (P > 0.05). During LASIK flap creation, intact corneal innervation is damaged, and the ocular surface lacrimal functional unit can be impaired. In our study, no abnormal dry eye test results were observed before or after the procedure. Based on our results, LASIK treatment is safe for dry eye involving the administration of adequate artificial tears for a minimum of 3 months.

  17. A Multicenter Study of the Presentation, Treatment, and Outcomes of Cervical Dural Tears.

    PubMed

    O'Neill, Kevin R; Fehlings, Michael G; Mroz, Thomas E; Smith, Zachary A; Hsu, Wellington K; Kanter, Adam S; Steinmetz, Michael P; Arnold, Paul M; Mummaneni, Praveen V; Chou, Dean; Nassr, Ahmad; Qureshi, Sheeraz A; Cho, Samuel K; Baird, Evan O; Smith, Justin S; Shaffrey, Christopher; Tannoury, Chadi A; Tannoury, Tony; Gokaslan, Ziya L; Gum, Jeffrey L; Hart, Robert A; Isaacs, Robert E; Sasso, Rick C; Bumpass, David B; Bydon, Mohamad; Corriveau, Mark; De Giacomo, Anthony F; Derakhshan, Adeeb; Jobse, Bruce C; Lubelski, Daniel; Lee, Sungho; Massicotte, Eric M; Pace, Jonathan R; Smith, Gabriel A; Than, Khoi D; Riew, K Daniel

    2017-04-01

    Retrospective multicenter case series study. Because cervical dural tears are rare, most surgeons have limited experience with this complication. A multicenter study was performed to better understand the presentation, treatment, and outcomes following cervical dural tears. Multiple surgeons from 23 institutions retrospectively identified 21 rare complications that occurred between 2005 and 2011, including unintentional cervical dural tears. Demographic data and surgical history were obtained. Clinical outcomes following surgery were assessed, and any reoperations were recorded. Neck Disability Index (NDI), modified Japanese Orthopaedic Association (mJOA), Nurick classification (NuC), and Short-Form 36 (SF36) scores were recorded at baseline and final follow-up at certain centers. All data were collected, collated, and analyzed by a private research organization. There were 109 cases of cervical dural tears among 18 463 surgeries performed. In 101 cases (93%) there was no clinical sequelae following successful dural tear repair. There were statistical improvements ( P < .05) in mJOA and NuC scores, but not NDI or SF36 scores. No specific baseline or operative factors were found to be associated with the occurrence of dural tears. In most cases, no further postoperative treatments of the dural tear were required, while there were 13 patients (12%) that required subsequent treatment of cerebrospinal fluid drainage. Analysis of those requiring further treatments did not identify an optimum treatment strategy for cervical dural tears. In this multicenter study, we report our findings on the largest reported series (n = 109) of cervical dural tears. In a vast majority of cases, no subsequent interventions were required and no clinical sequelae were observed.

  18. CO 2 storage and potential fault instability in the St. Lawrence Lowlands sedimentary basin (Quebec, Canada): Insights from coupled reservoir-geomechanical modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Konstantinovskaya, E.; Rutqvist, J.; Malo, M.

    2014-01-21

    In this paper, coupled reservoir-geomechanical (TOUGH-FLAC) modeling is applied for the first time to the St. Lawrence Lowlands region to evaluate the potential for shear failure along pre-existing high-angle normal faults, as well as the potential for tensile failure in the caprock units (Utica Shale and Lorraine Group). This activity is part of a general assessment of the potential for safe CO 2 injection into a sandstone reservoir (the Covey Hill Formation) within an Early Paleozoic sedimentary basin. Field and subsurface data are used to estimate the sealing properties of two reservoir-bounding faults (Yamaska and Champlain faults). The spatial variationsmore » in fluid pressure, effective minimum horizontal stress, and shear strain are calculated for different injection rates, using a simplified 2D geological model of the Becancour area, located ~110 km southwest of Quebec City. The simulation results show that initial fault permeability affects the timing, localization, rate, and length of fault shear slip. Contrary to the conventional view, our results suggest that shear failure may start earlier for a permeable fault than for a sealing fault, depending on the site-specific geologic setting. In simulations of a permeable fault, shear slip is nucleated along a 60 m long fault segment in a thin and brittle caprock unit (Utica Shale) trapped below a thicker and more ductile caprock unit (Lorraine Group) – and then subsequently progresses up to the surface. In the case of a sealing fault, shear failure occurs later in time and is localized along a fault segment (300 m) below the caprock units. The presence of the inclined low-permeable Yamaska Fault close to the injection well causes asymmetric fluid-pressure buildup and lateral migration of the CO 2 plume away from the fault, reducing the overall risk of CO 2 leakage along faults. Finally, fluid-pressure-induced tensile fracturing occurs only under extremely high injection rates and is localized below the

  19. Corneal Sensitivity in Tear Dysfunction and its Correlation with Clinical Parameters and Blink Rate

    PubMed Central

    Rahman, Effie Z.; Lam, Peter K.; Chu, Chia-Kai; Moore, Quianta; Pflugfelder, Stephen C.

    2015-01-01

    Purpose To compare corneal sensitivity in tear dysfunction due to a variety of causes using contact and non-contact esthesiometers and to evaluate correlations between corneal sensitivity, blink rate and clinical parameters. Design Comparative observational case series. Methods Ten normal and 33 subjects with tear dysfunction [meibomian gland disease (n = 11), aqueous tear deficiency (n = 10) - without (n = 7) and with (n = 3) Sjögren syndrome (SS) and conjunctivochalasis (n = 12)] were evaluated. Corneal sensitivity was measured with Cochet-Bonnet and air jet esthesiometers and blink rate by electromyelography. Eye irritation symptoms, tear meniscus height, tear break-up time (TBUT), and corneal and conjunctival dye staining were measured. Between group means were compared and correlations calculated. Results Compared with control (Cochet-Bonnet 5.45 mm, air esthesiometer 3.62 mg), mean sensory thresholds were significantly higher in aqueous tear deficiency using either Cochet-Bonnet (3.6 mm; P = 0.003) or air (11.7 mg; P = 0.046) esthesiometers, but were not significantly different in the other groups. Reduced corneal sensitivity significantly correlated with more rapid TBUT and blink rate, and greater irritation and ocular surface dye staining with one or both esthesiometers. Mean blink rates were significantly higher in both aqueous tear deficiency and conjunctivochalasis compared with control. Among all subjects, blink rate positively correlated with ocular surface staining and irritation and inversely correlated with TBUT. Conclusion Amongst conditions causing tear dysfunction, reduced corneal sensitivity is associated with greater irritation, tear instability, ocular surface disease and blink rate. Rapid blinking is associated with worse ocular surface disease and tear stability. PMID:26255576

  20. Silicone Hydrogel and Rigid Gas-Permeable Scleral Lens Tear Exchange.

    PubMed

    Paugh, Jerry R; Chen, Elaine; Heinrich, Colton; Miller, Heidi; Gates, Tiffany; Nguyen, Andrew Loc; Edrington, Timothy; Weissman, Barry A

    2018-03-01

    To quantify tear elimination rate (ER) underneath silicone hydrogel (Si-Hy) and scleral gas permeable (GP) contact lenses (CLs). Subjects successfully using either well-fitting soft Si-Hy CLs or scleral GP CLs were recruited. Most scleral GP CL wearers had irregular corneas (e.g., keratoconus). An objective fluorometer measured decay of fluorescein isothiocyanate dextran dye signal (70 kD MW) from which the tear ER in %/min was calculated. For GP scleral lenses, the ER was determined for both the initial settling period and the 30- to 60-min period, and without lenses. All ERs were calculated from 5 to 30 min to avoid reflex tearing effects. Fourteen soft Si-Hy CL and 12 scleral GP CL wearers completed the study. The ER for the scleral GP CL wearers averaged 0.57 (±0.6) %/min for the 0- to 30-min and 0.42 (±0.5) %/min for the 30- to 60-min period (P=0.515). Non-CL wear tear ER in these same subjects averaged 34.17 (±15.9) %/min and was significantly different versus both scleral GP wear periods (both P values <0.001). The ER for the soft Si-Hy CL wearers, 5 to 30 min, averaged 6.09 (±2.8) %/min. Our data demonstrate significantly less ER in well-fit scleral GP CL wearers compared with soft Si-Hy CL wearers for both the settling and longer wear periods (both P values <0.001). Moreover, slightly greater tear exchange was observed during the scleral GP CL settling period than later, which may reflect a change over time in tear vault thickness.

  1. [Evaluation of chemokines in tears of patients with infectious keratitis].

    PubMed

    Hori, Shinsuke; Shoji, Jun; Inada, Noriko; Sawa, Mitsuru

    2013-02-01

    To investigate the chemokine profile in tears of patients with infectious keratitis. Subjects were 32 eyes of 16 patients with infectious keratitis and 5 eyes of 5 healthy volunteers as a control. The patients with infectious keratitis were classified into two groups of eyes: 10 with bacterial keratitis and 6 with Acanthamoeba keratitis. Tear fluid was obtained from both eyes of the patients with infectious keratitis and from the right eyes of the control subjects using filter paper. Chemokine concentration (unit: Odu/mm2) and its profile in tears was analyzed using an antibody-array. In terms of chemokine profile in the bacterial keratitis group, the expression volume of interleukin-8 (IL-8) and monocyte chemoattractant protein-1 (MCP-1) in the diseased eyes was significantly higher than in the healthy eyes (p < 0.05). The expression volume of mucosae-associated epithelial chemokines (MECs) in the diseased eyes of the bacterial keratitis group was significantly lower than in the healthy eyes of that group (p < 0.05). In the Acanthamoeba keratitis group, chemokines were not significantly increased in the diseased eyes compared with those in the healthy eyes. However, MCP-1 was increased in tears of the Acanthamoeba keratitis group. Regarding the chemokine ratio, the IL-8/MEC ratio in the diseased eyes of the Pseudomonas keratitis group and the MCP-1/IL-8 in the diseased eyes of the Acanthamoeba keratitis group showed a significantly high level (p < 0.05). We concluded that the analyses of the chemokine profile and chemokine ratio in the tears of infectious keratitis patients is useful as a clinical tear laboratory test to interpret the pathologic condition of infectious keratitis

  2. Location of eastern Mediterranean hot springs induced by mantle heat flow due to slab roll-back and tearing

    NASA Astrophysics Data System (ADS)

    Roche, V. M.; Sternai, P.; Guillou-Frottier, L.; Jolivet, L.; Gerya, T.

    2016-12-01

    The Aegean-Anatolian retreating subduction and collision zones have been investigated through 3D numerical geodynamic models involving slab rollback/tearing/breakoff constrained by, for instance, seismic tomography or anisotropy and geochemical proxies. Here we integrate these investigations by using geothermal anomaly measurements from western Turkey. Such data provides insights into the thermal state of the Aegean-Anatolian region at depth and reflects the development of a widespread active geothermal province that is unlikely to be related only to the Quaternary volcanism because this has a too limited extent in space and time. Firstly, we look for possible connections with larger-scale mantle dynamics and use 3D high-resolution petrological and thermo-mechanical numerical models to quantify the potential contribution of the Aegean-Anatolian subduction dynamics to such measured thermal anomalies. Secondly, the subduction-induced thermal signature at the base of the continental crust is then inserted as the imposed basal thermal condition of 2D models dedicated to the understanding of fluid flow in the shallow crust. These models couple heat transfer and fluid flow equations with appropriate fluid and rock physical properties. Results from the 3D numerical models suggest an efficient control of subduction-related asthenospheric return flow on the regional distribution of thermal anomalies. Results from the 2D numerical models also highlight that low angle normal faults (detachments) in the back-arc region can control the bulk of the heat transport and fluid circulation patterns. Such detachments can drain hot crustal and/or mantellic fluids down to several kilometers depths, thus allowing for or fostering deep fluid circulation.

  3. Active transfer fault zone linking a segmented extensional system (Betics, southern Spain): Insight into heterogeneous extension driven by edge delamination

    NASA Astrophysics Data System (ADS)

    Martínez-Martínez, José Miguel; Booth-Rea, Guillermo; Azañón, José Miguel; Torcal, Federico

    2006-08-01

    Pliocene and Quaternary tectonic structures mainly consisting of segmented northwest-southeast normal faults, and associated seismicity in the central Betics do not agree with the transpressive tectonic nature of the Africa-Eurasia plate boundary in the Ibero-Maghrebian region. Active extensional deformation here is heterogeneous, individual segmented normal faults being linked by relay ramps and transfer faults, including oblique-slip and both dextral and sinistral strike-slip faults. Normal faults extend the hanging wall of an extensional detachment that is the active segment of a complex system of successive WSW-directed extensional detachments which have thinned the Betic upper crust since middle Miocene. Two areas, which are connected by an active 40-km long dextral strike-slip transfer fault zone, concentrate present-day extension. Both the seismicity distribution and focal mechanisms agree with the position and regime of the observed faults. The activity of the transfer zone during middle Miocene to present implies a mode of extension which must have remained substantially the same over the entire period. Thus, the mechanisms driving extension should still be operating. Both the westward migration of the extensional loci and the high asymmetry of the extensional systems can be related to edge delamination below the south Iberian margin coupled with roll-back under the Alborán Sea; involving the asymmetric westward inflow of asthenospheric material under the margins.

  4. Fault kinematics and active tectonics of the Sabah margin: Insights from the 2015, Mw 6.0, Mt. Kinabalu earthquake

    NASA Astrophysics Data System (ADS)

    Wang, Y.; Wei, S.; Tapponnier, P.; WANG, X.; Lindsey, E.; Sieh, K.

    2016-12-01

    A gravity-driven "Mega-Landslide" model has been evoked to explain the shortening seen offshore Sabah and Brunei in oil-company seismic data. Although this model is considered to account simultaneously for recent folding at the edge of the submarine NW Sabah trough and normal faulting on the Sabah shelf, such a gravity-driven model is not consistent with geodetic data or critical examination of extant structural restorations. The rupture that produced the 2015 Mw6.0 Mt. Kinabalu earthquake is also inconsistent with the gravity-driven model. Our teleseismic analysis shows that the centroid depth of that earthquake's mainshock was 13 to 14 km, and its favored fault-plane solution is a 60° NW-dipping normal fault. Our finite-rupture model exhibits major fault slip between 5 and 15 km depth, in keeping with our InSAR analysis, which shows no appreciable surface deformation. Both the hypocentral depth and the depth of principal slip are far too deep to be explained by gravity-driven failure, as such a model would predict a listric normal fault connecting at a much shallower depth with a very gentle detachment. Our regional mapping of tectonic landforms also suggests the recent rupture is part of a 200-km long system of narrowly distributed active extension in northern Sabah. Taken together, the nature of the 2015 rupture, the belt of active normal faults, and structural consideration indicate that active tectonic shortening plays the leading role in controlling the overall deformation of northern Sabah and that deep-seated, onland normal faulting likely results from an abrupt change in the dip-angle of the collision interface beneath the Sabah accretionary prism.

  5. Ocular surface inflammation, and nerve growth factor level in tears in active thyroid-associated ophthalmopathy.

    PubMed

    Yoon, Jin Sook; Choi, Soo Hyun; Lee, Joon H; Lee, Sung Jun; Lee, Sang Yeul

    2010-02-01

    To measure tear nerve growth factor (NGF) concentrations in cases of active thyroid-associated ophthalmopathy (TAO) before and after glucocorticoid treatment, and to correlate NGF levels with disease inflammatory activity and thyroid autoantibody concentration. The study involved 20 patients with active TAO and 20 age- and gender-matched controls. Tear break-up time (BUT) was obtained, the Schirmer test was performed, and tear NGF/total protein ratio was measured in control subjects and patients with active TAO before, and 2 and 4 weeks after, steroid treatment. Tear BUT and Schirmer values significantly increased after 2 and 4 weeks of steroid treatment (p < 0.001 and p = 0.004 respectively). Baseline tear NGF/total protein ratio was higher in patients with active TAO than in control subjects, and the ratio significantly decreased after 2 and 4 weeks of steroid treatment (p < 0.001). Tear NGF/total protein ratio did not correlate with inflammatory activity score, exophthalmos value and thyroid binding inhibiting immunoglobulin (TBII) level (p > 0.05). Tear NGF may have a specific role in ocular surface inflammation, which protects against ocular surface damage in patients with active TAO. Anti-inflammatory treatment significantly reduced the level of NGF in tears, increased tear film stability and production, and decreased congestive symptoms.

  6. The Effects of Increasing Ocular Surface Stimulation on Blinking and Tear Secretion

    PubMed Central

    Wu, Ziwei; Begley, Carolyn G.; Port, Nicholas; Bradley, Arthur; Braun, Richard; King-Smith, Ewen

    2015-01-01

    Purpose. To investigate the effect of varying levels of ocular surface stimulation on the timing and amplitude of the blink and tear secretion. Methods. Following instillation of fluorescein dye, increasing levels of air flow were directed toward the central corneas of 10 healthy subjects. Interblink interval (IBI), tear meniscus height (TMH), and fluorescence intensity were measured simultaneously. Because blinking can obscure changes in TMH, we developed novel measures of tear secretion by calculating tear meniscus fluorescein concentration (TMFC) from intensity using a mathematical model. The change of TMH and TMFC over trials and the slope of the TMFC within each IBI (IBI-TTR) were further calculated. Results. The mean IBI was decreased by 8.08 ± 8.54 seconds from baseline to maximum air stimulation. The TMH increase was highly variable (0.41 ± 0.39 mm) among subjects, compared to the fluorescence tear turnover metrics: decrease in TMFC of 2.84 ± 0.98 natural logarithm or ln(%) and IBI-TTR of 0.065 ± 0.032 ln(%)/sec. Ocular surface stimulation was highly correlated with the TMFC and IBI-TTR, but less so with TMH (Pearson's r = 0.71, 0.69, and 0.40, P < 0.01, respectively). Blinking and tearing were significantly correlated with each other (Pearson's r = 0.56, P < 0.01), but tearing lagged behind by an average of 6.54 ± 4.07 seconds. Conclusions. Blinking and tearing share a common origin with sensory stimulation at the ocular surface. Both showed a dose–response increase with surface stimulation and were correlated with each other. These methods can potentially be used to understand alterations in ocular surface sensory function and associated protective responses in dry eye and other disorders of the ocular surface. PMID:26132780

  7. The Effects of Increasing Ocular Surface Stimulation on Blinking and Tear Secretion.

    PubMed

    Wu, Ziwei; Begley, Carolyn G; Port, Nicholas; Bradley, Arthur; Braun, Richard; King-Smith, Ewen

    2015-07-01

    To investigate the effect of varying levels of ocular surface stimulation on the timing and amplitude of the blink and tear secretion. Following instillation of fluorescein dye, increasing levels of air flow were directed toward the central corneas of 10 healthy subjects. Interblink interval (IBI), tear meniscus height (TMH), and fluorescence intensity were measured simultaneously. Because blinking can obscure changes in TMH, we developed novel measures of tear secretion by calculating tear meniscus fluorescein concentration (TMFC) from intensity using a mathematical model. The change of TMH and TMFC over trials and the slope of the TMFC within each IBI (IBI-TTR) were further calculated. The mean IBI was decreased by 8.08 ± 8.54 seconds from baseline to maximum air stimulation. The TMH increase was highly variable (0.41 ± 0.39 mm) among subjects, compared to the fluorescence tear turnover metrics: decrease in TMFC of 2.84 ± 0.98 natural logarithm or ln(%) and IBI-TTR of 0.065 ± 0.032 ln(%)/sec. Ocular surface stimulation was highly correlated with the TMFC and IBI-TTR, but less so with TMH (Pearson's r = 0.71, 0.69, and 0.40, P < 0.01, respectively). Blinking and tearing were significantly correlated with each other (Pearson's r = 0.56, P < 0.01), but tearing lagged behind by an average of 6.54 ± 4.07 seconds. Blinking and tearing share a common origin with sensory stimulation at the ocular surface. Both showed a dose-response increase with surface stimulation and were correlated with each other. These methods can potentially be used to understand alterations in ocular surface sensory function and associated protective responses in dry eye and other disorders of the ocular surface.

  8. Post-blink tear film dynamics in healthy and dry eyes during spontaneous blinking.

    PubMed

    Szczesna-Iskander, Dorota H

    2018-01-01

    The aim was to investigate the dynamics of post-blink tear film leveling in natural blinking conditions (NBC) for healthy subjects and those diagnosed with dry eye syndrome (DES) and to relate this phase to the tear film surface quality (TFSQ) before the following blink. The study included 19 healthy persons and 10 with dry eye, grouped according to symptoms and signs observed during examination. Lateral shearing interferometry was used to examine TFSQ. Post-blink tear film dynamics was modeled by an exponential function, characterized by the decay parameter b, and a constant, describing the level of the stabilized TFSQ. Pre-next-natural-blink TFSQ dynamics was modeled with a linear trend, described by a parameter A. The post-blink tear film dynamics reached its plateau at a significantly (P = 0.006) lower level in the normal tear film group than in the dry eye group. The median exponential decay parameter b was statistically significantly higher for the control group than for the DES group, P = 0.026. The parameter b calculated for each interblink interval was significantly correlated with the corresponding parameter A (Spearman's R = 0.35; P < 0.001). Correlation between the median b and tear film fluorescein break-up time for each subject was also found (R = 0.41, P = 0.029). Significantly faster leveling of post-natural-blink tear film was observed in the group with DES than in healthy eyes. This dynamic was correlated with the pre-next-natural-blink TFSQ and tear film stability. The results of this pilot study support previous works that advocate the importance of polar lipids in the mechanism of tear film lipid spreading. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Similar Prevalence of Acetabular Labral Tear in Professional Ballet Dancers and Sporting Participants.

    PubMed

    Mayes, Susan; Ferris, April-Rose; Smith, Peter; Garnham, Andrew; Cook, Jill

    2016-07-01

    To compare the prevalence of acetabular labral tear in male and female professional ballet dancers with age-matched and sex-matched sporting participants and to determine the relationship to clinical findings and cartilage defects. Case-control study. Clinical and radiology practices. Forty-nine (98 hips) male and female professional ballet dancers (current and retired) with median age 30 years (range: 19-64 years) and 49 (98 hips) age-matched and sex-matched sporting participants. Group (ballet or sports), sex, age, hip cartilage defects, history of hip pain, Hip and Groin Outcome Score, passive hip internal rotation (IR), and external rotation range of movement (ROM). Labral tear identified with 3T magnetic resonance imaging (MRI). Labral tears were identified in 51% of all 196 hips. The prevalence did not differ significantly between the ballet and sporting participants (P = 0.41) or between sexes (P = 0.34). Labral tear was not significantly associated with clinical measures, such as pain and function scores or rotation ROM (P > 0.01 for all). Pain provocation test using IR at 90° of hip flexion had excellent specificity [96%, 95% confidence intervals (CIs), 0.77%-0.998%] but poor sensitivity (50%, 95% CI, 0.26%-0.74%) for identifying labral tear in participants reporting hip pain. Older age and cartilage defect presence were independently associated with an increased risk of labral tear (both P < 0.001). The prevalence of labral tear in male and female professional ballet dancers was similar to a sporting population. Labral tears were not associated with clinical findings but were related to cartilage defects, independent of aging. Caution is required when interpreting MRI findings as labral tear may not be the source of the ballet dancer's symptoms.

  10. Transfer zones in listric normal fault systems

    NASA Astrophysics Data System (ADS)

    Bose, Shamik

    Listric normal faults are common in passive margin settings where sedimentary units are detached above weaker lithological units, such as evaporites or are driven by basal structural and stratigraphic discontinuities. The geometries and styles of faulting vary with the types of detachment and form landward and basinward dipping fault systems. Complex transfer zones therefore develop along the terminations of adjacent faults where deformation is accommodated by secondary faults, often below seismic resolution. The rollover geometry and secondary faults within the hanging wall of the major faults also vary with the styles of faulting and contribute to the complexity of the transfer zones. This study tries to understand the controlling factors for the formation of the different styles of listric normal faults and the different transfer zones formed within them, by using analog clay experimental models. Detailed analyses with respect to fault orientation, density and connectivity have been performed on the experiments in order to gather insights on the structural controls and the resulting geometries. A new high resolution 3D laser scanning technology has been introduced to scan the surfaces of the clay experiments for accurate measurements and 3D visualizations. Numerous examples from the Gulf of Mexico have been included to demonstrate and geometrically compare the observations in experiments and real structures. A salt cored convergent transfer zone from the South Timbalier Block 54, offshore Louisiana has been analyzed in detail to understand the evolutionary history of the region, which helps in deciphering the kinematic growth of similar structures in the Gulf of Mexico. The dissertation is divided into three chapters, written in a journal article format, that deal with three different aspects in understanding the listric normal fault systems and the transfer zones so formed. The first chapter involves clay experimental models to understand the fault patterns in

  11. Fault finder

    DOEpatents

    Bunch, Richard H.

    1986-01-01

    A fault finder for locating faults along a high voltage electrical transmission line. Real time monitoring of background noise and improved filtering of input signals is used to identify the occurrence of a fault. A fault is detected at both a master and remote unit spaced along the line. A master clock synchronizes operation of a similar clock at the remote unit. Both units include modulator and demodulator circuits for transmission of clock signals and data. All data is received at the master unit for processing to determine an accurate fault distance calculation.

  12. Surgery or conservative treatment for rotator cuff tear: a meta-analysis.

    PubMed

    Ryösä, Anssi; Laimi, Katri; Äärimaa, Ville; Lehtimäki, Kaisa; Kukkonen, Juha; Saltychev, Mikhail

    2017-07-01

    Comparative evidence on treating rotator cuff tear is inconclusive. The objective of this review was to evaluate the evidence on effectiveness of tendon repair in reducing pain and improving function of the shoulder when compared with conservative treatment of symptomatic rotator cuff tear. Search on CENTRAL, MEDLINE, EMBASE, CINAHL, Web of Science and Pedro databases. Randomised controlled trials (RCT) comparing surgery and conservative treatment of rotator cuff tear. Study selection and extraction based on the Cochrane Handbook for Systematic reviews of Interventions. Random effects meta-analysis. Three identified RCTs involved 252 participants (123 cases and 129 controls). The risk of bias was considered low for all three RCTs. For Constant score, statistically insignificant effect size was 5.6 (95% CI -0.41 to 11.62) points in 1-year follow up favouring surgery and below the level of minimal clinically important difference. The respective difference in pain reduction was -0.93 (95% CI -1.65 to -0.21) cm on a 0-10 pain visual analogue scale favouring surgery. The difference was statistically significant (p = 0.012) in 1-year follow up but below the level of minimal clinically important difference. There is limited evidence that surgery is not more effective in treating rotator cuff tear than conservative treatment alone. Thus, a conservative approach is advocated as the initial treatment modality. Implications for Rehabilitation There is limited evidence that surgery is not more effective in treating rotator cuff tear than conservative treatment alone. There was no clinically significant difference between surgery and active physiotherapy in 1-year follow-up in improving Constant score or reducing pain caused by rotator cuff tear. As physiotherapy is less proneness to complications and less expensive than surgery, a conservative approach is advocated as the initial treatment modality to rotator cuff tears.

  13. Post-lens tear turbidity and visual quality after scleral lens wear.

    PubMed

    Carracedo, Gonzalo; Serramito-Blanco, Maria; Martin-Gil, Alba; Wang, Zicheng; Rodriguez-Pomar, Candela; Pintor, Jesús

    2017-11-01

    The aim was to evaluate the turbidity and thickness of the post-lens tear layer and its effect on visual quality in patients with keratoconus after the beginning of lens wear and before lens removal at the end of eight hours. Twenty-six patients with keratoconus (aged 36.95 ± 8.95 years) participated voluntarily in the study. The sample was divided into two groups: patients with intrastromal corneal ring (ICRS group) and patients without ICRS (KC group). Distance visual acuity (VA), contrast sensitivity, pachymetry, post-lens tear layer height and post-lens tear layer turbidity (percentage area occupied and number of particles per mm 2 ) were evaluated with optical coherence tomography before and after wearing a scleral lens. A significant increase of turbidity was found in all groups assessed (p < 0.05). The number of particles per square millimetre was eight times higher after scleral lens wear than at the beginning of wearing the lens for all groups. VA decreases in all groups after scleral lens wear (p < 0.001). All patients showed a statistical diminishing of contrast sensitivity after scleral lens wear (p < 0.05). A significant correlation was found for both turbidity parameters with distance VA but no correlation between turbidity and post-lens tear layer thickness at the beginning was found (p > 0.05). A strong correlation in all groups between the post-lens tear layer at the beginning and differences of tear layer thickness between two measures was also found (p < 0.05). The VA decrease during the scleral lens wearing, filled with preserved saline solution, was due to the increasing post-lens tear layer turbidity. © 2017 Optometry Australia.

  14. Determination of phosphate concentration and pH in artificial tear drops.

    PubMed

    de Frutos-Lezaun, M; Martínez-Soroa, I; Ostra Beldarrain, M; Egia Zurutuza, A; Irastorza Larburu, M B; Fernandez Iriarte, A; Bachiller Cacho, M P

    2016-08-01

    To determine phosphate concentration and pH in artificial tear eye drops commercially available in Spain. A total of 71 examples of artificial tear preparations were identified in a search of Vademecum 2014 and the Spanish Medicines Agency website. In the 24 artificial tear products containing phosphates, quantification of these was performed by ultraviolet molecular absorption spectrophotometry, and the determination of pH was performed using scan image analysis algorithms of pH strips. Of the 71 artificial tears tested, 24 contained phosphate among their excipients in the data sheet, three of which had a concentration level below detection limit (<0.1mM). The mean phosphate concentration was 17.91±23.87mM. The artificial tear sample containing a higher concentration was Colircusi Humectante (87.1mM). Lubricants based on hypromellose showed the highest phosphate concentration (41.59±32.1mM), showing statistically significant differences compared to povidone (P=.0196) and hyaluronate (P=.0067). Statistically significant differences were found between products containing preservatives (32.39±20.91mM), and preservative free ones (8.49±11.98mM) (P=.0498). However, no difference was found between multidose (20.21±26.91mM) and unidose (9.31±14.39mM) samples, or between brand name (15.44±23.3mM) and generic eye drops (20.81mM). The mean pH was 6.93±0.26 (6.2-7.22). No statistical correlation was detected between phosphate concentration and pH (Spearman's Rho -0.1089 and P=.6125). A total of 24 (33.8%) of the 71 artificial tears contained phosphate. We believe identifying the phosphate concentration of artificial tears is useful information in order to avoid complications in high-risk patients. Copyright © 2016. Published by Elsevier España, S.L.U.

  15. Noninvasive Continuous Monitoring of Tear Glucose Using Glucose-Sensing Contact Lenses.

    PubMed

    Ascaso, Francisco J; Huerva, Valentín

    2016-04-01

    : The incidence of diabetes mellitus is dramatically increasing in the developed countries. Tight control of blood glucose concentration is crucial to diabetic patients to prevent microvascular complications. Self-monitoring of blood glucose is widely used for controlling blood glucose levels and usually performed by an invasive test using a portable glucometer. Many technologies have been developed over the past decades with the purpose of obtaining a continuous physiological glycemic monitoring. A contact lens is the ideal vehicle for continuous tear glucose monitoring of glucose concentration in tear film. There are several research groups that are working in the development of contact lenses with embedded biosensors for continuously and noninvasively monitoring tear glucose levels. Although numerous aspects must be improved, contact lens technology is one step closer to helping diabetic subjects better manage their condition, and these contact lenses will be able to measure the level of glucose in the wearer's tears and communicate the information to a mobile phone or computer. This article reviews studies on ocular glucose and its monitoring methods as well as the attempts to continuously monitor the concentration of tear glucose by using contact lens-based sensors.

  16. The Sorong Fault Zone, Indonesia: Mapping a Fault Zone Offshore

    NASA Astrophysics Data System (ADS)

    Melia, S.; Hall, R.

    2017-12-01

    The Sorong Fault Zone is a left-lateral strike-slip fault zone in eastern Indonesia, extending westwards from the Bird's Head peninsula of West Papua towards Sulawesi. It is the result of interactions between the Pacific, Caroline, Philippine Sea, and Australian Plates and much of it is offshore. Previous research on the fault zone has been limited by the low resolution of available data offshore, leading to debates over the extent, location, and timing of movements, and the tectonic evolution of eastern Indonesia. Different studies have shown it north of the Sula Islands, truncated south of Halmahera, continuing to Sulawesi, or splaying into a horsetail fan of smaller faults. Recently acquired high resolution multibeam bathymetry of the seafloor (with a resolution of 15-25 meters), and 2D seismic lines, provide the opportunity to trace the fault offshore. The position of different strands can be identified. On land, SRTM topography shows that in the northern Bird's Head the fault zone is characterised by closely spaced E-W trending faults. NW of the Bird's Head offshore there is a fold and thrust belt which terminates some strands. To the west of the Bird's Head offshore the fault zone diverges into multiple strands trending ENE-WSW. Regions of Riedel shearing are evident west of the Bird's Head, indicating sinistral strike-slip motion. Further west, the ENE-WSW trending faults turn to an E-W trend and there are at least three fault zones situated immediately south of Halmahera, north of the Sula Islands, and between the islands of Sanana and Mangole where the fault system terminates in horsetail strands. South of the Sula islands some former normal faults at the continent-ocean boundary with the North Banda Sea are being reactivated as strike-slip faults. The fault zone does not currently reach Sulawesi. The new fault map differs from previous interpretations concerning the location, age and significance of different parts of the Sorong Fault Zone. Kinematic

  17. Acromion Index in Korean Population and Its Relationship with Rotator Cuff Tears.

    PubMed

    Kum, Dong Ho; Kim, Jun Ho; Park, Keun Min; Lee, Eun Su; Park, Yong Bok; Yoo, Jae Chul

    2017-06-01

    Among the many causes of rotator cuff tears, scapular morphology is associated with the accelerating degenerative process of the rotator cuff. Acromion index (AI) was previously introduced and compared in two populations. We enrolled 100 Korean patients diagnosed with full-thickness rotator cuff tears by magnetic resonance imaging and intraoperative arthroscopic findings between January and December 2013. Another 100 Korean patients with an intact rotator cuff tendon identified on magnetic resonance imaging and other shoulder diseases, such as frozen shoulder and instability, were enrolled as controls. We retrospectively compared these 100 rotator cuff tear patients (mean age, 63 years) and 100 controls (mean age, 51 years) in this study. Two independent orthopedic surgeons assessed the AI on radiographs. We performed an interobserver reliability test of the AI assessment, and then compared the AI between two groups. The measurement of the AI showed excellent reliability (intraclass correlation coefficient, 0.82). The mean AI in the rotator cuff tear group was 0.68 and it was significantly different between groups ( p <0.001, 95% confidence interval). The AI was not related to tear size. Our study showed that the AI was an effective predictive factor for rotator cuff tears in a Korean population.

  18. No prosthetic management of massive and irreparable rotator cuff tears

    PubMed Central

    Garofalo, Raffaele; Cesari, Eugenio

    2014-01-01

    A massive rotator cuff tear is not necessarily irreparable. Number of tendons involved, muscle-tendon unit quality, and decreased acromionhumeral distance (AHD) are as important as tear size in determining reparability of lesion. Massive and irreparable rotator cuff tears cannot be anatomically repaired to the bone and are a common source of pain and disability even in middle-aged patients. In these patients when conservative management has failed, it is possible to perform different surgical techniques. A functional repair can help to restore the horizontal force couple of the cuff on the humeral head and to increase the AHD. Debridement of irreparable tears and biceps tenotomy or tenodesis can have a role in low functional demand patients but results deteriorate over time. Recently, several commercially available tissue-engineered biological and synthetic scaffolds have been developed to augment rotator cuff repairs. The aim is to provide a mechanical improvement in case of poor quality tissue at time zero and give a support to have a better cuff healing. In selected cases, the scaffold can be used also to bridge tendon defect. Patients who not have pseudoparalysis, cuff tear arthropathy and with intact deltoid function can benefit from tendon transfers with satisfactory outcomes. These different procedures should be chosen for each patient with selected criteria and after a satisfactory explanation about the really possible expectation after surgery. PMID:27582930

  19. Predicting Dural Tear in Compound Depressed Skull Fractures: A Prospective Multicenter Correlational Study.

    PubMed

    Salia, Shemsedin Musefa; Mersha, Hagos Biluts; Aklilu, Abenezer Tirsit; Baleh, Abat Sahlu; Lund-Johansen, Morten

    2018-06-01

    Compound depressed skull fracture (DSF) is a neurosurgical emergency. Preoperative knowledge of dural status is indispensable for treatment decision making. This study aimed to determine predictors of dural tear from clinical and imaging characteristics in patients with compound DSF. This prospective, multicenter correlational study in neurosurgical hospitals in Addis Ababa, Ethiopia, included 128 patients operated on from January 1, 2016, to October 31, 2016. Clinical, imaging, and intraoperative findings were evaluated. Univariate and multivariate analyses were used to establish predictors of dural tear. A logistic regression model was developed to predict probability of dural tear. Model validation was done using the receiver operating characteristic curve. Dural tear was seen in 55.5% of 128 patients. Demographics, injury mechanism, clinical presentation, and site of DSF had no significant correlation with dural tear. In univariate and multivariate analyses, depth of fracture depression (odds ratio 1.3, P < 0.001), pneumocephalus (odds ratio 2.8, P = 0.005), and brain contusions/intracerebral hematoma (odds ratio 5.5, P < 0.001) were significantly correlated with dural tear. We developed a logistic regression model (diagnostic test) to calculate probability of dural tear. Using the receiver operating characteristic curve, we determined the cutoff value for a positive test giving the highest accuracy to be 30% with a corresponding sensitivity of 93.0% and specificity of 43.9%. Dural tear in compound DSF can be predicted with 93.0% sensitivity using preoperative findings and may guide treatment decision making in resource-limited settings where risk of extensive cranial surgery outweighs the benefit. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Incidence and patterns of meniscal tears accompanying the anterior cruciate ligament injury: possible local and generalized risk factors.

    PubMed

    Mansori, Ashraf El; Lording, Timothy; Schneider, Antoine; Dumas, Raphael; Servien, Elvire; Lustig, Sebastien

    2018-05-26

    Injury to the anterior cruciate ligament (ACL) is frequently accompanied by tears of the menisci. Some of these tears occur at the time of injury, but others develop over time in the ACL-deficient knee. The aim of this study was to evaluate the effects of the patient characteristics, time from injury (TFI), and posterior tibial slope (PTS) on meniscal tear patterns. Our hypothesis was that meniscal tears would occur more frequently in ACL-deficient knees with increasing age, weight, TFI, PTS, and in male patients. Of the ACL-injured patients, 362 were analyzed, and details of meniscal lesions were collected. The medial and lateral tibial slopes (MTS, LTS) were measured via computed tomography. Patient demographics, TFI, MTS, and LTS were correlated with the diagnosed meniscal tears. Of the patients, 113 had a medial meniscus (MM) tear, 54 patients had a lateral meniscus (LM) tear, 34 patients had tears of both menisci, and 161 patients had no meniscal tear. The most common tear location was the posterior horn (PH) of the MM, followed by tear involving the whole MM. Patient age, BMI, and TFI were significantly associated with the incidence of MM tear. Female patients had a higher incidence of injury than males in all tear sites except in the body and PH. Male patients had more vertical and peripheral tears. The median MTS and LTS for patients with MM tears were 7.0°and 8.7°, respectively, while those of patients with LM tears were 6.9° and 8.1°. Steeper LTS was significantly associated with tears of LM and of both menisci. Older age, male sex, increased BMI, and prolonged TFI were significant factors for the development of MM tears. An increase in the tibial slope, especially of the lateral plateau, seems to increase the risk of tear of the LM and of both menisci. Level III.

  1. Association of parameniscal cysts with underlying meniscal tears as identified on MRI and arthroscopy.

    PubMed

    De Smet, Arthur A; Graf, Ben K; del Rio, Alejandro Munoz

    2011-02-01

    Although patients with parameniscal cysts usually have underlying meniscal tears, we noted that this association was less common with anterior lateral cysts. We wished to determine whether the frequency of a meniscal tear underlying a parameniscal cyst varied with cyst location. We reviewed a database of 7,771 knee MR examinations and identified 134 patients with an MR diagnosis of 138 parameniscal cysts and correlative arthroscopy in 78 patients. We reviewed their medical records and MR studies to determine the location of the cysts and presence of an underlying meniscal tear as determined by MRI or arthroscopy. There were 50 lateral and 88 medial parameniscal cysts. Medial meniscal tears were found underlying a cyst in 96% of arthroscopy patients and 86% of patients who had only MR examinations without a location difference in tears (p = 0.68). Meniscal tears were found on MRI or arthroscopy in all 28 patients with a lateral cyst overlying the body or posterior horn of the lateral meniscus, whereas a tear was found on MRI or arthroscopy in only 14 (64%) of 22 patients with cysts adjacent to or extending to the lateral meniscus anterior horn (p = 0.006). Anterior lateral cysts extended medially either into the root or into Hoffa fat-pad, but the type of extension did not correlate with the presence of an underlying meniscal tear. In contrast to medial parameniscal cysts or cysts at other locations adjacent to the lateral meniscus, anteriorly located lateral parameniscal cysts are less likely to have underlying meniscal tears.

  2. Lactoferrin Levels in Tears are Increased by the Topical Application of Diadenosine Tetraphosphate.

    PubMed

    Loma, Patricia; Guzman-Aranguez, Ana; Perez de Lara, Maria J; Pintor, Jesus

    2016-09-01

    This study was undertaken to determine the effect of the topical application of diadenosine tetraphosphate on lactoferrin levels in rabbit tears. Diadenosine tetraphosphate was topically instilled in a single-dose, tear samples were collected by micropipette and lactoferrin was measured by Enzyme-Linked ImmunoSorbent Assay (ELISA). The concentration of lactoferrin in rabbit tears was significantly increased 1 h after diadenosine tetraphosphate application, remaining elevated for 3 h more. This effect was blocked by P2 receptors antagonists. Topical application of diadenosine tetraphosphate stimulates the secretion of lactoferrin in rabbit tears through P2 receptor activation.

  3. Facile Determination of Sodium Ion and Osmolarity in Artificial Tears by Sequential DNAzymes.

    PubMed

    Kim, Eun Hye; Lee, Eun-Song; Lee, Dong Yun; Kim, Young-Pil

    2017-12-07

    Despite high relevance of tear osmolarity and eye abnormality, numerous methods for detecting tear osmolarity rely upon expensive osmometers. We report a reliable method for simply determining sodium ion-based osmolarity in artificial tears using sequential DNAzymes. When sodium ion-specific DNAzyme and peroxidase-like DNAzyme were used as a sensing and detecting probe, respectively, the concentration of Na⁺ in artificial tears could be measured by absorbance or fluorescence intensity, which was highly correlated with osmolarity over the diagnostic range ( R ² > 0.98). Our approach is useful for studying eye diseases in relation to osmolarity.

  4. The Art of Dressing Selection: A Consensus Statement on Skin Tears and Best Practice.

    PubMed

    LeBlanc, Kimberly; Baranoski, Sharon; Christensen, Dawn; Langemo, Diane; Edwards, Karen; Holloway, Samantha; Gloeckner, Mary; Williams, Ann; Campbell, Karen; Alam, Tarik; Woo, Kevin Y

    2016-01-01

    To provide information about product selection for the management of skin tears. This continuing education activity is intended for physicians and nurses with an interest in skin and wound care. After participating in this educational activity, the participant should be better able to:1. Explain skin tear (ST) risk factors and assessment guidelines.2. Identify best practice treatments for STs, including the appropriate dressings for each ST type. To aid healthcare professionals in product selection specific for skin tears, the International Skin Tear Advisory Panel conducted a systematic literature review and 3-phase Delphi consensus with a panel of international reviewers to provide the best available evidence for product selection related to the treatment of skin tears.

  5. Mapping fault-controlled volatile migration in equatorial layered deposits on Mars

    NASA Astrophysics Data System (ADS)

    Okubo, C. H.

    2006-12-01

    techniques that are developed for exploring terrestrial geologic reservoirs. This will yield maps of latent pathways for volatile migration through the faulted layered deposits and provide insight into the geologic history of volatiles on Mars.

  6. Fault zone hydrogeology

    NASA Astrophysics Data System (ADS)

    Bense, V. F.; Gleeson, T.; Loveless, S. E.; Bour, O.; Scibek, J.

    2013-12-01

    Deformation along faults in the shallow crust (< 1 km) introduces permeability heterogeneity and anisotropy, which has an important impact on processes such as regional groundwater flow, hydrocarbon migration, and hydrothermal fluid circulation. Fault zones have the capacity to be hydraulic conduits connecting shallow and deep geological environments, but simultaneously the fault cores of many faults often form effective barriers to flow. The direct evaluation of the impact of faults to fluid flow patterns remains a challenge and requires a multidisciplinary research effort of structural geologists and hydrogeologists. However, we find that these disciplines often use different methods with little interaction between them. In this review, we document the current multi-disciplinary understanding of fault zone hydrogeology. We discuss surface- and subsurface observations from diverse rock types from unlithified and lithified clastic sediments through to carbonate, crystalline, and volcanic rocks. For each rock type, we evaluate geological deformation mechanisms, hydrogeologic observations and conceptual models of fault zone hydrogeology. Outcrop observations indicate that fault zones commonly have a permeability structure suggesting they should act as complex conduit-barrier systems in which along-fault flow is encouraged and across-fault flow is impeded. Hydrogeological observations of fault zones reported in the literature show a broad qualitative agreement with outcrop-based conceptual models of fault zone hydrogeology. Nevertheless, the specific impact of a particular fault permeability structure on fault zone hydrogeology can only be assessed when the hydrogeological context of the fault zone is considered and not from outcrop observations alone. To gain a more integrated, comprehensive understanding of fault zone hydrogeology, we foresee numerous synergistic opportunities and challenges for the discipline of structural geology and hydrogeology to co-evolve and

  7. Interactions between Polygonal Normal Faults and Larger Normal Faults, Offshore Nova Scotia, Canada

    NASA Astrophysics Data System (ADS)

    Pham, T. Q. H.; Withjack, M. O.; Hanafi, B. R.

    2017-12-01

    Polygonal faults, small normal faults with polygonal arrangements that form in fine-grained sedimentary rocks, can influence ground-water flow and hydrocarbon migration. Using well and 3D seismic-reflection data, we have examined the interactions between polygonal faults and larger normal faults on the passive margin of offshore Nova Scotia, Canada. The larger normal faults strike approximately E-W to NE-SW. Growth strata indicate that the larger normal faults were active in the Late Cretaceous (i.e., during the deposition of the Wyandot Formation) and during the Cenozoic. The polygonal faults were also active during the Cenozoic because they affect the top of the Wyandot Formation, a fine-grained carbonate sedimentary rock, and the overlying Cenozoic strata. Thus, the larger normal faults and the polygonal faults were both active during the Cenozoic. The polygonal faults far from the larger normal faults have a wide range of orientations. Near the larger normal faults, however, most polygonal faults have preferred orientations, either striking parallel or perpendicular to the larger normal faults. Some polygonal faults nucleated at the tip of a larger normal fault, propagated outward, and linked with a second larger normal fault. The strike of these polygonal faults changed as they propagated outward, ranging from parallel to the strike of the original larger normal fault to orthogonal to the strike of the second larger normal fault. These polygonal faults hard-linked the larger normal faults at and above the level of the Wyandot Formation but not below it. We argue that the larger normal faults created stress-enhancement and stress-reorientation zones for the polygonal faults. Numerous small, polygonal faults formed in the stress-enhancement zones near the tips of larger normal faults. Stress-reorientation zones surrounded the larger normal faults far from their tips. Fewer polygonal faults are present in these zones, and, more importantly, most polygonal faults

  8. Fault diagnosis

    NASA Technical Reports Server (NTRS)

    Abbott, Kathy

    1990-01-01

    The objective of the research in this area of fault management is to develop and implement a decision aiding concept for diagnosing faults, especially faults which are difficult for pilots to identify, and to develop methods for presenting the diagnosis information to the flight crew in a timely and comprehensible manner. The requirements for the diagnosis concept were identified by interviewing pilots, analyzing actual incident and accident cases, and examining psychology literature on how humans perform diagnosis. The diagnosis decision aiding concept developed based on those requirements takes abnormal sensor readings as input, as identified by a fault monitor. Based on these abnormal sensor readings, the diagnosis concept identifies the cause or source of the fault and all components affected by the fault. This concept was implemented for diagnosis of aircraft propulsion and hydraulic subsystems in a computer program called Draphys (Diagnostic Reasoning About Physical Systems). Draphys is unique in two important ways. First, it uses models of both functional and physical relationships in the subsystems. Using both models enables the diagnostic reasoning to identify the fault propagation as the faulted system continues to operate, and to diagnose physical damage. Draphys also reasons about behavior of the faulted system over time, to eliminate possibilities as more information becomes available, and to update the system status as more components are affected by the fault. The crew interface research is examining display issues associated with presenting diagnosis information to the flight crew. One study examined issues for presenting system status information. One lesson learned from that study was that pilots found fault situations to be more complex if they involved multiple subsystems. Another was pilots could identify the faulted systems more quickly if the system status was presented in pictorial or text format. Another study is currently under way to

  9. Altered cytokine balance in the tear fluid and conjunctiva of patients with Sjögren's syndrome keratoconjunctivitis sicca.

    PubMed

    Pflugfelder, S C; Jones, D; Ji, Z; Afonso, A; Monroy, D

    1999-09-01

    epithelium increased as Schirmer 1 scores decreased (P tear fluid and conjunctival epithelium is altered in Sjögren's syndrome. The severity of keratoconjunctivitis sicca in this condition increases as tear fluid EGF concentration decreases and levels of inflammatory cytokines in the conjunctival epithelium increase. These findings provide new insight into the pathogenesis of keratoconjunctivitis and provide potential targets for therapy.

  10. Aspergillus flavus induced alterations in tear protein profile reveal pathogen-induced host response to fungal infection.

    PubMed

    Kandhavelu, Jeyalakshmi; Demonte, Naveen Luke; Namperumalsamy, Venkatesh Prajna; Prajna, Lalitha; Thangavel, Chitra; Jayapal, Jeya Maheshwari; Kuppamuthu, Dharmalingam

    2017-01-30

    Aspergillus flavus and Fusarium sp. are primary causative agents of keratitis that results in corneal tissue damage leading to vision loss particularly in individuals from the tropical parts of the world. Proteins in the tear film collected from control and keratitis patients was profiled and compared. A total of 1873 proteins from control and 1400 proteins from patient tear were identified by mass spectrometry. While 847 proteins were found to be glycosylated in the patient tear, only 726 were glycosylated in control tear. And, some of the tear proteins showed alterations in their glycosylation pattern after infection. Complement system proteins, proteins specific for neutrophil extracellular traps and proteins involved in would healing were found only in the patient tear. The presence of these innate immune system proteins in the tear film of patients supports the previous data indicating the involvement of neutrophil and complement pathways in antifungal defense. High levels of wound healing proteins in keratitis patient tear implied activation of tissue repair during infection. The early appearance of the host defense proteins and wound healing response indicates that tear proteins could be used as an early marker system for monitoring the progression of pathogenesis. Identification of negative regulators of the above defense pathways in keratitis tear indicates an intricate balance of pro and anti-defense mechanisms operating in fungal infection of the eye. Tear proteins from control and mycotic keratitis patients were separated into glycoproteins and non-glycosylated proteins and then identified by mass spectrometry. Tear proteins from keratitis patients showed alteration in the glycosylation pattern indicating the alteration of glycosylation machinery due to infection. Neutrophil extracellular traps specific proteins, complement pathway proteins, as well as wound healing proteins, were found only in patient tear showing the activation of antifungal defense

  11. Effect of lipid-based dry eye supplements on the tear film in wearers of eye cosmetics.

    PubMed

    Wang, Michael T M; Cho, Irene Sung Hee; Jung, Soo Hee; Craig, Jennifer P

    2017-08-01

    To compare the effects on tear film parameters and contamination in cosmetic eyeliner wearers, after single application of two lipid-based dry eye treatments: a lipid-containing lubricant eye drop and a phospholipid liposomal spray. Fifty participants were enrolled in a prospective, randomised, paired-eye, investigator-masked trial. Pencil eyeliner (Body Shop ® Crayon Eye Definer) was applied to the upper eyelid periocular skin of both eyes, anterior to the lash line. Baseline tear film quality was assessed fifteen minutes after eyeliner application. A lubricant drop (Systane ® Balance) was then applied to one eye (randomised), and liposomal spray (Tears Again ® ) to the contralateral eye. Tear film contamination, lipid layer grade, non-invasive tear film break-up time and tear evaporation rate were evaluated fifteen minutes post-treatment and compared to pre-treatment values. Pre-treatment measurements did not differ between eyes assigned to lubricant drop and liposomal spray. Tear film contamination was observed in a greater proportion of eyes following both treatments (both p<0.05), with no significant difference between treatments (p=0.41). Both treatments improved lipid layer thickness (both p≤0.01), but effected no significant change in non-invasive tear film break-up time or tear evaporation rate (all p>0.05). Changes in tear film parameters did not differ between treatments (all p>0.05). Both the lipid-containing lubricant eye drop and phospholipid liposomal spray result in clinically apparent tear film contamination in eyeliner cosmetic wearers. Although both treatments effected an increase in lipid layer thickness, neither displayed clinical efficacy in improving tear film stability. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  12. Is nonoperative management of partial distal biceps tears really successful?

    PubMed

    Bauer, Tyler M; Wong, Justin C; Lazarus, Mark D

    2018-04-01

    The current treatment of partial distal biceps tears is a period of nonoperative management, followed by surgery, if symptoms persist. Little is known about the success rate and outcomes of nonoperative management of this illness. We identified 132 patients with partial distal biceps tears through an International Classification of Diseases, Ninth Revision code query of our institution's database. Patient records were reviewed to abstract demographic information and confirm partial tears of the distal biceps tendon based on clinical examination findings and confirmatory magnetic resonance imaging (MRI). Seventy-four patients completed an outcome survey. In our study, 55.7% of the contacted patients who tried a nonoperative course (34 of 61 patients) ultimately underwent surgery, and 13 patients underwent immediate surgery. High-need patients, as defined by occupation, were more likely to report that they recovered ideally if they underwent surgery, as compared with those who did not undergo surgery (odds ratio, 11.58; P = .0138). For low-need patients, the same analysis was not statistically significant (P = .139). There was no difference in satisfaction scores between patients who tried a nonoperative course before surgery and those who underwent immediate surgery (P = .854). An MRI-diagnosed tear of greater than 50% was a predictor of needing surgery (odds ratio, 3.0; P = .006). This study has identified clinically relevant information for the treatment of partial distal biceps tears, including the following: the failure rate of nonoperative treatment, the establishment of MRI percent tear as a predictor of failing nonoperative management, the benefit of surgery for the high-need occupational group, and the finding that nonoperative management does not negatively affect outcome if subsequent surgery is necessary. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  13. HSV-1 DNA in Tears and Saliva of Normal Adults

    PubMed Central

    Kaufman, Herbert E.; Azcuy, Ann M.; Varnell, Emily D.; Sloop, Gregory D.; Thompson, Hilary W.; Hill, James M.

    2005-01-01

    Purpose. To assess the frequency of shedding of herpes simplex virus type 1 (HSV-1) DNA in tears and saliva of asymptomatic individuals. Methods Fifty subjects without signs of ocular herpetic disease participated. Serum samples from all subjects were tested for HSV IgG antibodies by enzyme-linked immunosorbent assay (ELISA) and for HSV-1 by neutralization assay. HSV-1 DNA copy number and frequency of shedding were determined by real-time polymerase chain reaction (PCR) analysis of tear and saliva samples collected twice daily for 30 consecutive days. Results Thirty-seven (74%) of the 50 subjects were positive for HSV IgG by ELISA. The percentages of positive eye and mouth swabs were approximately equivalent: 33.5% (941/2806) and 37.5% (1020/2723), respectively. However, the percentage of samples with high HSV-1 genome copy numbers was greater in saliva than in tears, which may have been a result of the sample volume collected. Shedding frequency in tears was nearly the same in men (347/1003; 34.6%) and women (594/1705; 34.8%); in saliva, men had a higher frequency of shedding (457/1009; 45.3% vs. 563/1703; 33.1%, men versus women). Overall, 49 (98%) of 50 subjects shed HSV-1 DNA at least once during the course of the 30-day study. Conclusions The percentage of asymptomatic subjects who intermittently shed HSV-1 DNA in tears or saliva was higher than the percentage of subjects with positive ELISA or neutralization antibodies to HSV. Because most HSV transmission occurs during asymptomatic shedding, further knowledge of the prevalence of HSV-1 DNA in tears and saliva is warranted to control its spread. Shedding is simple to study, and its suppression may be an efficient way to evaluate new antivirals in humans. PMID:15623779

  14. The effect of a rotator cuff tear and its size on three-dimensional shoulder motion.

    PubMed

    Kolk, Arjen; Henseler, Jan Ferdinand; de Witte, Pieter Bas; van Zwet, Erik W; van der Zwaal, Peer; Visser, Cornelis P J; Nagels, Jochem; Nelissen, Rob G H H; de Groot, Jurriaan H

    2017-06-01

    Rotator cuff-disease is associated with changes in kinematics, but the effect of a rotator cuff-tear and its size on shoulder kinematics is still unknown in-vivo. In this cross-sectional study, glenohumeral and scapulothoracic kinematics of the affected shoulder were evaluated using electromagnetic motion analysis in 109 patients with 1) subacromial pain syndrome (n=34), 2) an isolated supraspinatus tear (n=21), and 3) a massive rotator cuff tear involving the supraspinatus and infraspinatus (n=54). Mixed models were applied for the comparisons of shoulder kinematics between the three groups during abduction and forward flexion. In the massive rotator cuff-tear group, we found reduced glenohumeral elevation compared to the subacromial pain syndrome (16°, 95% CI [10.5, 21.2], p<0.001) and the isolated supraspinatus tear group (10°, 95% CI [4.0, 16.7], p=0.002) at 110° abduction. Reduced glenohumeral elevation in massive rotator cuff tears coincides with an increase in scapulothoracic lateral rotation compared to subacromial pain syndrome (11°, 95% CI [6.5, 15.2], p<0.001) and supraspinatus tears (7°, 95% CI [1.8, 12.1], p=0.012). Comparable differences were observed for forward flexion. No differences in glenohumeral elevation were found between the subacromial pain syndrome and isolated supraspinatus tear group during arm elevation. The massive posterosuperior rotator cuff-tear group had substantially less glenohumeral elevation and more scapulothoracic lateral rotation compared to the other groups. These observations suggest that the infraspinatus is essential to preserve glenohumeral elevation in the presence of a supraspinatus tear. Shoulder kinematics are associated with rotator cuff-tear size and may have diagnostic potential. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. The presence and significance of polar meibum and tear lipids.

    PubMed

    Pucker, Andrew D; Haworth, Kristina M

    2015-01-01

    The ocular tear film is a complex structure composed of a number of elements. While all of these components serve valuable functional and structural roles, the external lipid layer has been a focus because it is known to play a critical role in dry eye. Traditionally, meibomian gland phospholipids have been considered to be the vital amphiphilic molecules needed to create an interphase between the outer nonpolar lipid layer and inner aqueous layers, yet recent work has called this theory into question. The purpose of this review is to clarify the current understanding of the origins, identity, and significance of polar tear lipids. Studies indicate that both phospholipids and ω-hydroxy fatty acids likely play a critical role in tear film stability. Studies also indicate that polar lipids likely originate from multiple sources and that they are integrally involved in ocular surface disease. Additional studies are needed to fully understand the origins and significance of polar tear lipids, because to date only correlational evidence has described their hypothesized origins and functions. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Particle Energization via Tearing Instability with Global Self-Organization Constraints

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sarff, John; Guo, Fan

    The presentation reviews how tearing magnetic reconnection leads to powerful ion energization in reversed field pinch (RFP) plasmas. A mature MHD model for tearing instability has been developed that captures key nonlinear dynamics from the global to intermediate spatial scales. A turbulent cascade is also present that extends to at least the ion gyroradius scale, within which important particle energization mechanisms are anticipated. In summary, Ion heating and acceleration associated with magnetic reconnection from tearing instability is a powerful process in the RFP laboratory plasma (gyro-resonant and stochastic processes are likely candidates to support the observed rapid heating and othermore » features, reconnection-driven electron heating appears weaker or even absent, energetic tail formation for ions and electrons). Global self-organization strongly impacts particle energization (tearing interactions that span to core to edge, global magnetic flux change produces a larger electric field and runaway, correlations in electric and magnetic field fluctuations needed for dynamo feedback, impact of transport processes (which can be quite different for ions and electrons), inhomogeneity on the system scale, e.g., strong edge gradients).« less

  17. A New Criterion for Prediction of Hot Tearing Susceptibility of Cast Alloys

    NASA Astrophysics Data System (ADS)

    Nasresfahani, Mohamad Reza; Niroumand, Behzad

    2014-08-01

    A new criterion for prediction of hot tearing susceptibility of cast alloys is suggested which takes into account the effects of both important mechanical and metallurgical factors and is believed to be less sensitive to the presence of volume defects such as bifilms and inclusions. The criterion was validated by studying the hot tearing tendency of Al-Cu alloy. In conformity with the experimental results, the new criterion predicted reduction of hot tearing tendency with increasing the copper content.

  18. Influence of Fault Surface Heterogeneity on Apparent Frictional Strength, Slip Mode and Rupture Mode: Insights from Meter-Scale Rock Friction Experiments

    NASA Astrophysics Data System (ADS)

    Xu, S.; Fukuyama, E.; Yamashita, F.; Mizoguchi, K.; Takizawa, S.; Kawakata, H.

    2016-12-01

    Influence of fault zone heterogeneity on the behavior of fault motion has been studied in many aspects, such as strain partitioning, heat generation, slip mode, rupture mode, and effective friction law. However, a multi-scale investigation of fault behavior due to heterogeneity was difficult in nature, because of the limited access to natural fault zones at the seismogenic depth and the lack of in situ high-resolution observations. To overcome these difficulties, we study the behavior of a meter-scale synthetic fault made of Indian metagabbro during laboratory direct shear experiments, utilizing high-density arrays of strain gauges mounted close to the fault. We focus on two target experiments that are loaded under the same normal stress of 6.7 MPa and loading rate of 0.01 mm/s, but with different initial surface conditions. To change the surface condition, we applied a fast loading experiment under a rate of 1 mm/s between the two target experiments. It turned out the fast loading activated many foreshocks before the mainshock and caused a roaming of the mainshock nucleation site. These features were closely related to the re-distribution of the real contact area and surface wear, which together reflected a more heterogeneous state of the surface condition. During the first target experiment before the fast loading, the synthetic fault moved in a classic stick-slip fashion and the typical rupture mode was subshear within the range of the fault length. However, during the second target experiment, the synthetic fault inherited the heterogeneous features generated from the previous fast loading, showing a macroscopic creep-like behavior that actually consisted of many small stick-slip events. The apparent frictional strength increased while the recurrence interval and the stress drop decreased, compared to the levels seen in the first target experiment. The rupture mode became more complicated; supershear phases sometimes emerged but may only exist transiently

  19. Intraocular Pressure, Tear Production, and Ocular Echobiometry in Guinea Pigs (Cavia porcellus)

    PubMed Central

    Rajaei, Seyed Mehdi; Mood, Maneli Ansari; Sadjadi, Reza; Azizi, Farzaneh

    2016-01-01

    The purpose of this study was to evaluate intraocular pressure (IOP) by means of rebound tonometry, to assess tear production by using the endodontic absorbent paper point tear test (EAPTT) and phenol red thread test (PRTT), and to determine the effects of time of day on IOP and tear production in guinea pigs. The study population comprised 24 healthy adult guinea pigs (12 male, 12 female; 48 eyes) of different breeds and ranging in age from 12 to 15 mo. IOP and tear production were measured at 3 time points (0700, 1500, and 2300) during a 24-h period. Overall values (mean ± 1 SD) were: IOP, 6.81 ± 1.41 mm Hg (range, 4.83 to 8.50); PRTT, 14.33 ± 1.35 mm (range, 12.50 to 16.83); and EAPTT, 8.54 ± 1.08 mm (range, 7.17 to 10.0 mm). In addition, ultrasound biometry was performed by using a B-mode system with linear 8-MHz transducer. This study reports reference values for IOP and tear production in guinea pigs. PMID:27423156

  20. Fluid-faulting evolution in high definition: Connecting fault structure and frequency-magnitude variations during the 2014 Long Valley Caldera, California earthquake swarm

    USGS Publications Warehouse

    Shelly, David R.; Ellsworth, William L.; Hill, David P.

    2016-01-01

    An extended earthquake swarm occurred beneath southeastern Long Valley Caldera between May and November 2014, culminating in three magnitude 3.5 earthquakes and 1145 cataloged events on 26 September alone. The swarm produced the most prolific seismicity in the caldera since a major unrest episode in 1997-1998. To gain insight into the physics controlling swarm evolution, we used large-scale cross-correlation between waveforms of cataloged earthquakes and continuous data, producing precise locations for 8494 events, more than 2.5 times the routine catalog. We also estimated magnitudes for 18,634 events (~5.5 times the routine catalog), using a principal component fit to measure waveform amplitudes relative to cataloged events. This expanded and relocated catalog reveals multiple episodes of pronounced hypocenter expansion and migration on a collection of neighboring faults. Given the rapid migration and alignment of hypocenters on narrow faults, we infer that activity was initiated and sustained by an evolving fluid pressure transient with a low-viscosity fluid, likely composed primarily of water and CO2 exsolved from underlying magma. Although both updip and downdip migration were observed within the swarm, downdip activity ceased shortly after activation, while updip activity persisted for weeks at moderate levels. Strongly migrating, single-fault episodes within the larger swarm exhibited a higher proportion of larger earthquakes (lower Gutenberg-Richter b value), which may have been facilitated by fluid pressure confined in two dimensions within the fault zone. In contrast, the later swarm activity occurred on an increasingly diffuse collection of smaller faults, with a much higher b value.

  1. Tear Osmolarity and Correlation With Ocular Surface Parameters in Patients With Dry Eye.

    PubMed

    Mathews, Priya M; Karakus, Sezen; Agrawal, Devika; Hindman, Holly B; Ramulu, Pradeep Y; Akpek, Esen K

    2017-11-01

    To analyze the distribution of tear film osmolarity in patients with dry eye and its association with other ocular surface parameters. Tear osmolarity and other quantitative dry eye parameters were obtained from patients with 1) clinically significant dry eye (significant symptoms and ocular surface staining, n = 131), 2) symptoms-only dry eye (significant symptoms but no significant ocular surface staining, n = 52), and 3) controls (no significant symptoms or staining, n = 42). Tear osmolarity varied significantly across groups (P = 0.01), with patients with clinically significant dry eye having the highest tear osmolarity (312.0 ± 16.9 mOsm/L), control patients having the lowest tear osmolarity (305.6 ± 9.7 mOsm/L), and patients with symptoms-only dry eye falling in between (307.4 ± 5.6 mOsm/L). Patients with clinically significant dry eye also tended to have a greater intereye difference in osmolarity (12.0 ± 13.4) than did the individuals with symptoms-only dry eye (9.1 ± 12.4) and controls (9.0 ± 7.4) (P = 0.06). In multivariable regression models, higher tear osmolarity was associated with higher Ocular Surface Disease Index, discomfort subscore (P = 0.02), and higher corneal and conjunctival staining scores (P < 0.01 for both). Worse eye tear osmolarity was not correlated with the corresponding tear film breakup time or Schirmer test (P > 0.05 for both). Individuals with symptomatic dry eye that is not yet clinically significant seem to have higher and more variable osmolarity measurements than controls, potentially indicating that changes in osmolarity precede clinical findings.

  2. Phospholipids and their degrading enzyme in the tears of soft contact lens wearers.

    PubMed

    Yamada, Masakazu; Mochizuki, Hiroshi; Kawashima, Motoko; Hata, Seiichiro

    2006-12-01

    Low tear phospholipids levels are associated with tear film instability in soft contact lens wearers. We assayed levels of phospholipids and their degrading enzyme secretory phospholipase A2 (sPLA2) both in tears and deposited on contact lenses composed of 2 hydrophilic materials after 1 day of routine use. Polymacon (Medalist; FDA group 1, low water/nonionic) and Etafilcon A (One Day Acuvue; group 4, high water/ionic) contact lenses were worn for 12 hours by 16 experienced contact lens wearers. Phospholipids in tear fluids and deposited on contact lenses were estimated by phosphorus determination with ammonium molybdate through enzymatic digestion. Double-antibody sandwich ELISA was used to determine group IIa sPLA2 concentrations, and sPLA2 activity was assayed using 1,2-diheptanoyl thio-phosphatidylcholine as substrate. Phospholipids concentrations in tears with Polymacon and Etafilcon A were 186 +/- 39 and 162 +/- 33 microg/mL, respectively. The latter concentration was significantly lower than that observed in the same subjects when not wearing contact lenses (P = 0.0023). In tears, both group IIa sPLA2 concentrations and enzymatic activity remained unchanged, regardless of lens wearing. However, Etafilcon A (0.57 +/- 0.09 microg/lens) showed more group IIa sPLA2 deposition than Polymacon (0.01 +/- 0.01 microg/lens; P < 0.001). Furthermore, group IIa sPLA2 deposited on Etafilcon A but not on Polymacon lenses retained its enzymatic activity. Significant differences of group IIa sPLA2 deposition were found in the 2 lenses tested. Such deposition might induce phospholipid hydrolysis in tears and thereby promote tear film instability in hydrophilic contact lens wearers.

  3. Evaluation of commercial glucometer test strips for potential measurement of glucose in tears.

    PubMed

    Cha, Kyoung Ha; Jensen, Gary C; Balijepalli, Anant S; Cohan, Bruce E; Meyerhoff, Mark E

    2014-02-04

    Tear glucose measurements have been suggested as a potential alternative to blood glucose monitoring for diabetic patients. While previous work has reported that there is a correlation between blood and tear glucose levels in humans, this link has not been thoroughly established and additional clinical studies are needed. Herein, we evaluate the potential of using commercial blood glucose test strips to measure glucose in tears. Of several blood glucose strips evaluated, only one brand exhibits the low detection limit required for quantitating glucose in tears. Calibration of these strips in the range of 0-100 μM glucose with an applied potential of 150 mV to the working electrode yields a sensitivity of 0.127 nA/μM and a limit of quantitation (LOQ) of 9 μM. The strips also exhibit ≤13% error (n = 3) for 25, 50, and 75 μM glucose in the presence of 10 μM acetaminophen, 100 μM ascorbic acid, and 100 μM uric acid. Measurements of glucose in tears from nine normal (nondiabetic) fasting human subjects using strips yielded glucose values within the range of 5-148 μM (mean = 47 μM, median = 43 μM), similar to those for human tears reported by others with more complex LC-MS methods. The glucometer strip method could facilitate more clinical studies to determine whether tear glucose and blood glucose levels sufficiently correlate for application to routine measurements in tears to supplement blood glucose testing. This would be especially helpful for children, adolescents, other Type 1 diabetics, and also for Type 2 diabetics who require treatment with insulin and cannot tolerate multiple finger sticks per day.

  4. Investigation of pepsin in tears of children with laryngopharyngeal reflux disease.

    PubMed

    Iannella, Giannicola; Di Nardo, Giovanni; Plateroti, Rocco; Rossi, Paolo; Plateroti, Andrea Maria; Mariani, Paola; Magliulo, Giuseppe

    2015-12-01

    Numerous investigations postulated that laryngopharyngeal reflux (LPR) is implicated in the pathogenesis of various upper airway inflammatory diseases as sinusitis or dacryostenosis. The presence of pepsin in tears might be confirmed the presuntive hypothesis of the arrival in the nasolacrimal ducts and precorneal tears film through the laryngopharyngeal reflux of either gastric acid or stomach secretions (pepsin) with inflammatory potentialities. The aim of this preliminary study was to identify the presence or absence of pepsin in the tears collected from children with a high suspicion of LPR who underwent 24-h pH (MII-pH) monitoring to confirm the disease. This study enrolled 20 patients suffering from symptoms of laryngopharyngeal reflux that underwent 24-h multichannel intraluminal impedance (MII)-pH monitoring to confirm the disease. The findings of the study group were compared with those of a control group of patients with negative pH monitoring. The quantitative analysis of human pepsin concentration in the tear samples was performed by ELISA method in both groups. Four children (20%) of the study group showed pepsin in the tears. All of the subjects belonging to the control group were negative for its presence. No difference differences in the total number of reflux episodes and the number of weakly basic reflux in the pepsin positive patients vs. pepsin negative children were present. 20% of the children with diagnosed LPR showed pepsin in the tears. Our specific investigation might provide information regarding sinusitis or dacryostenosis. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  5. Tear cytokine profile as a noninvasive biomarker of inflammation for ocular surface diseases: standard operating procedures.

    PubMed

    Wei, Yi; Gadaria-Rathod, Neha; Epstein, Seth; Asbell, Penny

    2013-12-23

    To provide standard operating procedures (SOPs) for measuring tear inflammatory cytokine concentrations and to validate the resulting profile as a minimally invasive objective metric and biomarker of ocular surface inflammation for use in multicenter clinical trials on dry eye disease (DED). Standard operating procedures were established and then validated with cytokine standards, quality controls, and masked tear samples collected from local and distant clinical sites. The concentrations of the inflammatory cytokines in tears were quantified using a high-sensitivity human cytokine multiplex kit. A panel of inflammatory cytokines was initially investigated, from which four key inflammatory cytokines (IL-1β, IL-6, INF-γ, and TNF-α) were chosen. Results with cytokine standards statistically satisfied the manufacturer's quality control criteria. Results with pooled tear samples were highly reproducible and reliable with tear volumes ranging from 4 to 10 μL. Incorporation of the SOPs into clinical trials was subsequently validated. Tear samples were collected at a distant clinical site, stored, and shipped to our Biomarker Laboratory, where a masked analysis of the four tear cytokines was successfully performed. Tear samples were also collected from a feasibility study on DED. Inflammatory cytokine concentrations were decreased in tears of subjects who received anti-inflammatory treatment. Standard operating procedures for human tear cytokine assessment suitable for multicenter clinical trials were established. Tear cytokine profiling using these SOPs may provide objective metrics useful for diagnosing, classifying, and analyzing treatment efficacy in inflammatory conditions of the ocular surface, which may further elucidate the mechanisms involved in the pathogenesis of ocular surface disease.

  6. Reading a 400,000-year record of earthquake frequency for an intraplate fault

    NASA Astrophysics Data System (ADS)

    Williams, Randolph T.; Goodwin, Laurel B.; Sharp, Warren D.; Mozley, Peter S.

    2017-05-01

    Our understanding of the frequency of large earthquakes at timescales longer than instrumental and historical records is based mostly on paleoseismic studies of fast-moving plate-boundary faults. Similar study of intraplate faults has been limited until now, because intraplate earthquake recurrence intervals are generally long (10s to 100s of thousands of years) relative to conventional paleoseismic records determined by trenching. Long-term variations in the earthquake recurrence intervals of intraplate faults therefore are poorly understood. Longer paleoseismic records for intraplate faults are required both to better quantify their earthquake recurrence intervals and to test competing models of earthquake frequency (e.g., time-dependent, time-independent, and clustered). We present the results of U-Th dating of calcite veins in the Loma Blanca normal fault zone, Rio Grande rift, New Mexico, United States, that constrain earthquake recurrence intervals over much of the past ˜550 ka—the longest direct record of seismic frequency documented for any fault to date. The 13 distinct seismic events delineated by this effort demonstrate that for >400 ka, the Loma Blanca fault produced periodic large earthquakes, consistent with a time-dependent model of earthquake recurrence. However, this time-dependent series was interrupted by a cluster of earthquakes at ˜430 ka. The carbon isotope composition of calcite formed during this seismic cluster records rapid degassing of CO2, suggesting an interval of anomalous fluid source. In concert with U-Th dates recording decreased recurrence intervals, we infer seismicity during this interval records fault-valve behavior. These data provide insight into the long-term seismic behavior of the Loma Blanca fault and, by inference, other intraplate faults.

  7. Unstable domains of tearing and Kelvin-Helmholtz instabilities in a rotating cylindrical plasma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fan, D. M.; Wei, L.; Wang, Z. X., E-mail: zxwang@dlut.edu.cn

    2014-09-15

    Effects of poloidal rotation profile on tearing and Kelvin-Helmholtz (KH) instabilities in a cylindrical plasma are investigated by using a reduced magnetohydrodynamic model. Since the poloidal rotation has different effects on the tearing and KH modes in different rotation regimes, four unstable domains are numerically identified, i.e., the destabilized tearing mode domain, stabilized tearing mode domain, stable-window domain, and unstable KH mode domain. It is also found that when the rotation layer is in the outer region of the rational surface, the stabilizing role of the rotation can be enhanced so significantly that the stable window domain is enlarged. Moreover,more » Alfvén resonances can be induced by the tearing and KH modes in such rotating plasmas. Radially wide profiles of current and vorticity perturbations can be formed when multiple current sheets on different resonance positions are coupled together.« less

  8. A New Kinematic Model for Polymodal Faulting: Implications for Fault Connectivity

    NASA Astrophysics Data System (ADS)

    Healy, D.; Rizzo, R. E.

    2015-12-01

    Conjugate, or bimodal, fault patterns dominate the geological literature on shear failure. Based on Anderson's (1905) application of the Mohr-Coulomb failure criterion, these patterns have been interpreted from all tectonic regimes, including normal, strike-slip and thrust (reverse) faulting. However, a fundamental limitation of the Mohr-Coulomb failure criterion - and others that assume faults form parallel to the intermediate principal stress - is that only plane strain can result from slip on the conjugate faults. However, deformation in the Earth is widely accepted as being three-dimensional, with truly triaxial stresses and strains. Polymodal faulting, with three or more sets of faults forming and slipping simultaneously, can generate three-dimensional strains from truly triaxial stresses. Laboratory experiments and outcrop studies have verified the occurrence of the polymodal fault patterns in nature. The connectivity of polymodal fault networks differs significantly from conjugate fault networks, and this presents challenges to our understanding of faulting and an opportunity to improve our understanding of seismic hazards and fluid flow. Polymodal fault patterns will, in general, have more connected nodes in 2D (and more branch lines in 3D) than comparable conjugate (bimodal) patterns. The anisotropy of permeability is therefore expected to be very different in rocks with polymodal fault patterns in comparison to conjugate fault patterns, and this has implications for the development of hydrocarbon reservoirs, the genesis of ore deposits and the management of aquifers. In this contribution, I assess the published evidence and models for polymodal faulting before presenting a novel kinematic model for general triaxial strain in the brittle field.

  9. Fault Management Practice: A Roadmap for Improvement

    NASA Technical Reports Server (NTRS)

    Fesq, Lorraine M.; Oberhettinger, David

    2010-01-01

    Autonomous fault management (FM) is critical for deep space and planetary missions where the limited communication opportunities may prevent timely intervention by ground control. Evidence of pervasive architecture, design, and verification/validation problems with NASA FM engineering has been revealed both during technical reviews of spaceflight missions and in flight. These problems include FM design changes required late in the life-cycle, insufficient project insight into the extent of FM testing required, unexpected test results that require resolution, spacecraft operational limitations because certain functions were not tested, and in-flight anomalies and mission failures attributable to fault management. A recent NASA initiative has characterized the FM state-of-practice throughout the spacecraft development community and identified common NASA, DoD, and commercial concerns that can be addressed in the near term through the development of a FM Practitioner's Handbook and the formation of a FM Working Group. Initial efforts will focus on standardizing FM terminology, establishing engineering processes and tools, and training.

  10. Fault tree models for fault tolerant hypercube multiprocessors

    NASA Technical Reports Server (NTRS)

    Boyd, Mark A.; Tuazon, Jezus O.

    1991-01-01

    Three candidate fault tolerant hypercube architectures are modeled, their reliability analyses are compared, and the resulting implications of these methods of incorporating fault tolerance into hypercube multiprocessors are discussed. In the course of performing the reliability analyses, the use of HARP and fault trees in modeling sequence dependent system behaviors is demonstrated.

  11. Organization of Lipids in the Tear Film: A Molecular-Level View

    PubMed Central

    Wizert, Alicja; Iskander, D. Robert; Cwiklik, Lukasz

    2014-01-01

    Biophysical properties of the tear film lipid layer are studied at the molecular level employing coarse grain molecular dynamics (MD) simulations with a realistic model of the human tear film. In this model, polar lipids are chosen to reflect the current knowledge on the lipidome of the tear film whereas typical Meibomian-origin lipids are included in the thick non-polar lipids subphase. Simulation conditions mimic those experienced by the real human tear film during blinks. Namely, thermodynamic equilibrium simulations at different lateral compressions are performed to model varying surface pressure, and the dynamics of the system during a blink is studied by non-equilibrium MD simulations. Polar lipids separate their non-polar counterparts from water by forming a monomolecular layer whereas the non-polar molecules establish a thick outermost lipid layer. Under lateral compression, the polar layer undulates and a sorting of polar lipids occurs. Moreover, formation of three-dimensional aggregates of polar lipids in both non-polar and water subphases is observed. We suggest that these three-dimensional structures are abundant under dynamic conditions caused by the action of eye lids and that they act as reservoirs of polar lipids, thus increasing stability of the tear film. PMID:24651175

  12. Rotator cuff crepitus: could Codman really feel a cuff tear?

    PubMed

    Ponce, Brent A; Kundukulam, Joseph A; Sheppard, Evan D; Determann, Jason R; McGwin, Gerald; Narducci, Carl A; Crowther, Marshall J

    2014-07-01

    The objective of this study was to assess the accuracy of palpating crepitus to diagnose rotator cuff tears. Seventy consecutive consenting patients who presented with shoulder pain and no previous imaging or surgery on the affected shoulder were prospectively enrolled during a 10-month period. A standardized patient history and examination, including the crepitus test, were recorded in addition to obtaining standard radiographs. Additional imaging after initial evaluation was performed with magnetic resonance imaging and interpreted by a musculoskeletal radiologist blinded to the examination findings. Statistical analysis was used to determine sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the crepitus test in the clinical diagnosis of a rotator cuff tear. Sixty-three patients had histories, examinations, and imaging studies available for analysis. The crepitus test had a sensitivity of 67%, specificity of 80%, PPV of 91%, and NPV of 43% for all types of rotator cuff tears. The sensitivity and specificity for full-thickness or high-grade partial tears was 82% and 73%, respectively; the PPV and NPV were 77% and 79%. Increasing age improved accuracy as the presence of crepitus in patients older than 55 years had a sensitivity of 76%, specificity of 100%, PPV of 100%, and NPV of 38%. The crepitus test has a favorable sensitivity, specificity, PPV, and NPV to assess the integrity of the rotator cuff and may be a useful examination in the clinical diagnosis of a rotator cuff tear. Published by Mosby, Inc.

  13. Repeatability of a new method for measuring tear evaporation rates.

    PubMed

    Petznick, Andrea; Tan, Jen Hong; Boo, Shiao Khee; Lee, Sze Yee; Acharya, U Rajendra; Tong, Louis

    2013-04-01

    The purpose of this study was to evaluate the repeatability of tear evaporimetry based on infrared thermography in a clinical room setting and to test the effect of changing environmental humidity on ocular surface temperature (OST) and tear evaporation rates (TERs) in a controlled adverse environmental (CAE) chamber. Twenty-six healthy participants were enrolled, of whom 16 underwent repeatability measurements in a clinical room and 10 were exposed to a constant temperature of 30°C with a humidity of 45 and 65% in a CAE. Participants were acclimatized to each condition for at least 20 minutes before OSTs were taken. Tear film breakup time was assessed in the CAE only. Number of blinks and OSTs were continuously measured for 20 seconds for the cornea, conjunctiva, and overall ocular surface with an infrared camera; corresponding TERs were calculated. The OSTs and TERs showed acceptable strength of agreement between the first and second measurements. The coefficients of repeatability were 0.4°C for OST and 6.0 W m for TER. An increase in chamber humidity (from 45 to 65%) increased OST (p < 0.05). The TER was not changed significantly (p > 0.05). The tear film breakup time and number of blinks were not significantly affected by different humidity conditions. This technique has acceptable repeatability and has potential to document individual tear evaporation changes with time where humidity may differ by less than 20%.

  14. Fault Tree Analysis.

    PubMed

    McElroy, Lisa M; Khorzad, Rebeca; Rowe, Theresa A; Abecassis, Zachary A; Apley, Daniel W; Barnard, Cynthia; Holl, Jane L

    The purpose of this study was to use fault tree analysis to evaluate the adequacy of quality reporting programs in identifying root causes of postoperative bloodstream infection (BSI). A systematic review of the literature was used to construct a fault tree to evaluate 3 postoperative BSI reporting programs: National Surgical Quality Improvement Program (NSQIP), Centers for Medicare and Medicaid Services (CMS), and The Joint Commission (JC). The literature review revealed 699 eligible publications, 90 of which were used to create the fault tree containing 105 faults. A total of 14 identified faults are currently mandated for reporting to NSQIP, 5 to CMS, and 3 to JC; 2 or more programs require 4 identified faults. The fault tree identifies numerous contributing faults to postoperative BSI and reveals substantial variation in the requirements and ability of national quality data reporting programs to capture these potential faults. Efforts to prevent postoperative BSI require more comprehensive data collection to identify the root causes and develop high-reliability improvement strategies.

  15. Influence of topical anesthesia on tear dynamics and ocular drug bioavailability in albino rabbits.

    PubMed

    Patton, T F; Robinson, J R

    1975-02-01

    The bioavailability of topically applied ocular drugs is very poor, due largely to drug loss through drainage and tear turnover. The use of high viscosity solutions or solid matrixes to delay or eliminate drainage is the usual approach for decreasing drug loss but the alternative approach of chemically reducing tear turnover and/or solution drainage has not been investigated. By means of a simple isotopic dilution technique, using radioactive technetium sulfur colloid, the quantitative influence of topical anesthetics on tear production and instilled solution drainage was determined. The reduction in the rate of tear turnover and solution drainage varies for different anesthetics and is dose dependent. The implication of these results for some long accepted clinical procedures is discussed, and questions are raised regarding the present understanding of the mechanisms of tear production. Quantitation of precorneal drug loss through instilled solution drainage and tear turnover permits the establishment of a baseline for ocular drug bioavailability. Aqueous humor drug concentration versus time profiles of radioactive pilocarpine nitrate were obtained, both in the presence and absence of topical anesthesia. The results verify the importance of tear turnover and instilled solution drainage as a major route of drug loss in the eye. Moreover, the success of the present study in improving ocular drug bioavailability by the chemical approach of repressing solution drainage and tear turnover suggests that this approach is viable for improving drug bioavailability.

  16. Can the optimum artificial tear treatment for dry eye disease be predicted from presenting signs and symptoms?

    PubMed

    Essa, Laika; Laughton, Deborah; Wolffsohn, James S

    2018-02-01

    To assess dry eye treatment with four preservative-free dry eye artificial tear treatments to facilitate evidence-based prescribing. A randomised, single masked crossover trial of Clinitas Soothe, Hyabak, Tears Again and TheraTears artificial tears was conducted on 50 symptomatic dry eye patients, aged 60.8±14.2years. At baseline and after trialling each treatment for 4 weeks, signs and symptoms were assessed using the Ocular Surface Disease Index (OSDI), non-invasive tear break-up time, fluorescein tear break-up time, tear meniscus height (TMH), Phenol Red test, lid-parallel conjunctival folds (LIPCOF), ocular surface staining, and lipid layer grading and osmolarity (baseline visit only). OSDI (p=0.002), LIPCOF (p=0.014) and conjunctival staining (p<0.001) significantly improved from baseline, however, the impact of each dry eye treatment on ocular symptoms and signs was similar. Clinitas Soothe and Hyabak were preferred by 34%/30% of participants, but only subjective comparison with the other drops influenced this choice. TheraTears was preferred (by 24%) by those with a lower baseline tear volume (p=0.01) and Tears Again (by 12%) by those with a thinner baseline lipid layer (p=0.04). The treatment that afforded the greatest improvement in clinical signs did not consistently match each individual's preferred treatment. If prescribed to a general dry eye population, the artificial tears performed similarly, improving symptoms and conjunctival signs. However, osmolarity balanced artificial tears were the preferred treatment in individuals with low baseline tear volume and lipisomal spray for individuals with a baseline lipid layer deficiency. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  17. Fault fluid evolution at the outermost edges of the southern Apennines fold-and-thrust belt, Italy

    NASA Astrophysics Data System (ADS)

    Agosta, Fabrizio; Belviso, Claudia; Cavalcante, Francesco; Vita Petrullo, Angela

    2017-04-01

    This work focuses on the structural architecture and mineralization of a high-angle, extensional fault zone that crosscuts the Middle Pleistocene tuffs and pyroclastites of the Vulture Volcano, southern Italy. This fault zone is topped by a few m-thick travertine deposit formed by precipitation, in a typical lacustrine depositional environment, from a fault fluid that included a mixed, biogenic- and mantle-derived CO2. The detailed analysis of its different mineralization can shed new lights into the shallow crustal fluid flow that took place during deformation of the outer edge of the southern Apennines fold-and-thrust belt. In fact, the study fault zone is interpreted as a shallow-seated, tear fault associated with a shallow thrust fault displacing the most inner portion of the Bradano foredeep basin infill, and was thus active during the latest stages of contractional deformation. Far from the fault zone, the fracture network is made up of three high-angle joint sets striking N-S, E-W and NW-SE, respectively. The former two sets can be interpreted as the older structural elements that pre-dated the latter one, which is likely due to the current stress state that affects the whole Italian peninsula. In the vicinity of the fault zone, a fourth joint high-angle set striking NE-SW is also present, which becomes the most dominant fracture set within the study footwall fault damage zone. Detailed X-ray diffraction analysis of the powder obtained from hand specimens representative of the multiple mineralization present within the fault zone, and in the surrounding volcanites, are consistent with circulation of a fault fluid that modified its composition with time during the latest stages of volcanic activity and contractional deformation. Specifically, veins infilled with and slickenside coated by jarosite, Opal A and/or goethite are found in the footwall fault damage zone. Based upon the relative timing of formation of the aforementioned joint sets, deciphered after

  18. Delaminated rotator cuff tear: extension of delamination and cuff integrity after arthroscopic rotator cuff repair.

    PubMed

    Gwak, Heui-Chul; Kim, Chang-Wan; Kim, Jung-Han; Choo, Hye-Jeung; Sagong, Seung-Yeob; Shin, John

    2015-05-01

    The purpose of this study was to evaluate the extension of delamination and the cuff integrity after arthroscopic repair of delaminated rotator cuff tears. Sixty-five patients with delaminated rotator cuff tears were retrospectively reviewed. The delaminated tears were divided into full-thickness delaminated tears and partial-thickness delaminated tears. To evaluate the medial extension, we calculated the coronal size of the delaminated portion. To evaluate the posterior extension, we checked the tendon involved. Cuff integrity was evaluated by computed tomography arthrography. The mean medial extension in the full-thickness and partial-thickness delaminated tears was 18.1 ± 6.0 mm and 22.7 ± 6.3 mm, respectively (P = .0084). The posterior extension into the supraspinatus and the infraspinatus was 36.9% and 32.3%, respectively, in the full-thickness delaminated tears, and it was 27.7% and 3.1%, respectively, in the partial-thickness delaminated tears (P = .0043). With regard to cuff integrity, 35 cases of anatomic healing, 10 cases of partial healing defects, and 17 cases of retear were detected. Among the patients with retear and partial healing of the defect, all the partially healed defects showed delamination. Three retear patients showed delamination, and 14 retear patients did not show delamination; the difference was statistically significant (P = .0001). The full-thickness delaminated tears showed less medial extension and more posterior extension than the partial-thickness delaminated tears. Delamination did not develop in retear patients, but delamination was common in the patients with partially healed defects. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  19. Self-Sustained Mode-3 Tear Controls Dynamics of Narrow Retreating Subduction Zones

    NASA Astrophysics Data System (ADS)

    Munch, J.; Gerya, T.; Ueda, K.

    2017-12-01

    The Caribbean oroclinal basin exhibits several narrow retreating slabs in an oceanic domain. The slabs show a curved shape associated to a bent topography (trench). We propose that the curvature of the topography depends on slab retreat mechanisms following mode-3 tearing at the edges of the slab (out of the plane fracture propagation). While first-order characteristics have been principally reproduced in self-sustained subduction initiation models (Gerya et al., 2015, Nature, 527, 221-225), the relevant observations have not been quantified and the exact mechanism is not understood. In this work, we study the long-term 3D evolution of narrowing oceanic subduction zones during retreat, and investigate the link between mode-3 tear and orocline formation. Numerical experiments are carried out with a thermo-mechanical 3D finite-difference code. To allow the observation of developing topography, the precise location of the internal surface and its evolution by material diffusion is tracked. Retreating subduction is facilitated via a strong age contrast between a young lithosphere window enclosed by shear zones and the surrounding lithosphere. By varying the length and thickness of the shear zones and location of the age transition, the influence of these parameters on the tearing process and the development of topography is assessed. Experiments trigger subduction initiation and slab retreat via fracture zone collapse and spontaneous paired mode-3 tear propagation within the oceanic plate interior. Narrow retreating subducting slabs form as a natural result of the spontaneous paired tearing process. A curved trench forms along with slab retreat. Topography evolution and tearing trajectory appear to be dependent on the initial shear zones and young window dimensions. We also note a strong narrowing of the slab during the retreat (several tens of kilometers over 800 km of retreat). Overall, results indicate that narrowing of retreating slabs is a self

  20. THE CLINICAL, FUNCTIONAL AND BIOMECHANICAL PRESENTATION OF PATIENTS WITH SYMPTOMATIC HIP ABDUCTOR TENDON TEARS.

    PubMed

    Ebert, Jay R; Retheesh, Theertha; Mutreja, Rinky; Janes, Gregory C

    2016-10-01

    Hip abductor tendon (HAT) tearing is commonly implicated in greater trochanteric pain syndrome (GTPS), though limited information exists on the disability associated with this condition and specific presentation of these patients. To describe the clinical, functional and biomechanical presentation of patients with symptomatic HAT tears. Secondary purposes were to investigate the association between these clinical and functional measures, and to compare the pain and disability reported by HAT tear patients to those with end-stage hip osteoarthritis (OA). Prospective case series. One hundred forty-nine consecutive patients with symptomatic HAT tears were evaluated using the Harris (HHS) and Oxford (OHS) Hip Scores, SF-12, an additional series of 10 questions more pertinent to those with lateral hip pain, active hip range of motion (ROM), maximal isometric hip abduction strength, six-minute walk capacity and 30-second single limb stance (SLS) test. The presence of a Trendelenburg sign and pelvis-on-femur (POF) angle were determined via 2D video analysis. An age matched comparative sample of patients with end-stage hip OA was recruited for comparison of all patient-reported outcome scores. Independent t-tests investigated group and limb differences, while analysis of variance evaluated pain changes during the functional tests. Pearson's correlation coefficients investigated the correlation between clinical measures in the HAT tear group. No differences existed in patient demographics and patient-reported outcome scores between HAT tear and hip OA cohorts, apart from significantly worse SF-12 mental subscale scores (p = 0.032) in the HAT tear group. Patients with HAT tears demonstrated significantly lower (p < 0.05) hip abduction strength and active ROM in all planes of motion on their affected limb. Pain significantly increased throughout the 30-second SLS test for the HAT tear group, with 57% of HAT tear patients demonstrating a positive Trendelenburg sign

  1. THE CLINICAL, FUNCTIONAL AND BIOMECHANICAL PRESENTATION OF PATIENTS WITH SYMPTOMATIC HIP ABDUCTOR TENDON TEARS

    PubMed Central

    Retheesh, Theertha; Mutreja, Rinky; Janes, Gregory C.

    2016-01-01

    Background Hip abductor tendon (HAT) tearing is commonly implicated in greater trochanteric pain syndrome (GTPS), though limited information exists on the disability associated with this condition and specific presentation of these patients. Purpose To describe the clinical, functional and biomechanical presentation of patients with symptomatic HAT tears. Secondary purposes were to investigate the association between these clinical and functional measures, and to compare the pain and disability reported by HAT tear patients to those with end-stage hip osteoarthritis (OA). Study Design Prospective case series. Methods One hundred forty-nine consecutive patients with symptomatic HAT tears were evaluated using the Harris (HHS) and Oxford (OHS) Hip Scores, SF-12, an additional series of 10 questions more pertinent to those with lateral hip pain, active hip range of motion (ROM), maximal isometric hip abduction strength, six-minute walk capacity and 30-second single limb stance (SLS) test. The presence of a Trendelenburg sign and pelvis-on-femur (POF) angle were determined via 2D video analysis. An age matched comparative sample of patients with end-stage hip OA was recruited for comparison of all patient-reported outcome scores. Independent t-tests investigated group and limb differences, while analysis of variance evaluated pain changes during the functional tests. Pearson's correlation coefficients investigated the correlation between clinical measures in the HAT tear group. Results No differences existed in patient demographics and patient-reported outcome scores between HAT tear and hip OA cohorts, apart from significantly worse SF-12 mental subscale scores (p = 0.032) in the HAT tear group. Patients with HAT tears demonstrated significantly lower (p < 0.05) hip abduction strength and active ROM in all planes of motion on their affected limb. Pain significantly increased throughout the 30-second SLS test for the HAT tear group, with 57% of HAT tear patients

  2. Location of Rotator Cuff Tear Initiation: A Magnetic Resonance Imaging Study of 191 Shoulders.

    PubMed

    Jeong, Jeung Yeol; Min, Seul Ki; Park, Keun Min; Park, Yong Bok; Han, Kwang Joon; Yoo, Jae Chul

    2018-03-01

    Degenerative rotator cuff tears (RCTs) are generally thought to originate at the anterior margin of the supraspinatus tendon. However, a recent ultrasonography study suggested that they might originate more posteriorly than originally thought, perhaps even from the isolated infraspinatus (ISP) tendon, and propagate toward the anterior supraspinatus. Hypothesis/Purpose: It was hypothesized that this finding could be reproduced with magnetic resonance imaging (MRI). The purpose was to determine the most common location of degenerative RCTs by using 3-dimensional multiplanar MRI reconstruction. It was assumed that the location of the partial-thickness tears would identify the area of the initiation of full-thickness tears. Cross-sectional study; Level of evidence, 3. A retrospective analysis was conducted including 245 patients who had RCTs (nearly full- or partial-thickness tears) at the outpatient department between January 2011 and December 2013. RCTs were measured on 3-dimensional multiplanar reconstruction MRI with OsiriX software. The width and distance from the biceps tendon to the anterior margin of the tear were measured on T2-weighted sagittal images. In a spreadsheet, columns of consecutive numbers represented the size of each tear (anteroposterior width) and their locations with respect to the biceps brachii tendon. Data were pooled to graphically represent the width and location of all tears. Frequency histograms of the columns were made to visualize the distribution of tears. The tears were divided into 2 groups based on width (group A, <10 mm; group B, <20 and ≥10 mm) and analyzed for any differences in location related to size. The mean width of all RCTs was 11.9 ± 4.1 mm, and the mean length was 11.1 ± 5.0 mm. Histograms showed the most common location of origin to be 9 to 10 mm posterior to the biceps tendon. The histograms of groups A and B showed similar tear location distributions, indicating that the region approximately 10 mm posterior to

  3. Strength of the San Andreas Fault Zone: Insight From SAFOD Cuttings and Core

    NASA Astrophysics Data System (ADS)

    Tembe, S.; Lockner, D. A.; Solum, J. G.; Morrow, C. A.; Wong, T.; Moore, D. E.

    2005-12-01

    Cuttings acquired during drilling of the SAFOD scientific hole near Parkfield, California offer a continuous physical record of the lithology across the San Andreas fault (SAF) zone and provide the only complete set of samples available for laboratory testing. Guided by XRD clay mineral analysis and velocity and gamma logs, we selected washed cuttings from depths spanning the main hole from 1.85 to 3.0 km true vertical depth. Cuttings were chosen to represent primary lithologic units as well as significant shear zones, including candidates for the currently active SAF. To determine frictional properties triaxial sliding tests were conducted on cylindrical granite blocks containing sawcuts inclined at 30° and filled with 1 mm-thick sample gouge layers. Tests were run at constant effective normal stresses of 10 and 40 MPa and constant pore pressure of 1 MPa. Samples were sheared up to 10.4 mm at room temperature and velocities of 1, 0.1 and 0.01 μm/s. Stable sliding behavior and overall strain hardening were observed in all tests. The coefficient of friction typically showed a modest decrease with increasing effective normal stress and mostly velocity strengthening was observed. Preliminary results yield coefficients of friction, μ, which generally fell into two clusters spanning the range of 0.45 to 0.8. The higher values of friction (~0.7 - 0.8) corresponded to quartzofeldspathic samples derived from granodiorites and arkoses encountered in the drill hole. Lower values of friction (0.45 - 0.55) were observed at depth intervals interpreted as shear zones based on enriched clay content, reduced seismic velocities and increased gamma radiation. Arguments for a weak SAF suggest coseismic frictional strength of μ = 0.1 to 0.2 yet the actual fault zone materials studied here appear consistently stronger. At least two important limitations exist for inferring in-situ fault strength from cuttings. (1) Clays and weak minerals are preferentially lost during drilling and

  4. Fault-tolerant cooperative output regulation for multi-vehicle systems with sensor faults

    NASA Astrophysics Data System (ADS)

    Qin, Liguo; He, Xiao; Zhou, D. H.

    2017-10-01

    This paper presents a unified framework of fault diagnosis and fault-tolerant cooperative output regulation (FTCOR) for a linear discrete-time multi-vehicle system with sensor faults. The FTCOR control law is designed through three steps. A cooperative output regulation (COR) controller is designed based on the internal mode principle when there are no sensor faults. A sufficient condition on the existence of the COR controller is given based on the discrete-time algebraic Riccati equation (DARE). Then, a decentralised fault diagnosis scheme is designed to cope with sensor faults occurring in followers. A residual generator is developed to detect sensor faults of each follower, and a bank of fault-matching estimators are proposed to isolate and estimate sensor faults of each follower. Unlike the current distributed fault diagnosis for multi-vehicle systems, the presented decentralised fault diagnosis scheme in each vehicle reduces the communication and computation load by only using the information of the vehicle. By combing the sensor fault estimation and the COR control law, an FTCOR controller is proposed. Finally, the simulation results demonstrate the effectiveness of the FTCOR controller.

  5. Meniscal pathology associated with acute anterior cruciate ligament tears in patients with open physes.

    PubMed

    Samora, Walter P; Palmer, Ryan; Klingele, Kevin E

    2011-01-01

    The purpose of this study is to characterize meniscal pathology associated with anterior cruciate ligament (ACL) rupture in skeletally immature patients. We also evaluate the accuracy of preoperative magnetic resonance imaging (MRI) in predicting ACL and meniscus pathology. A retrospective chart review was performed on 124 skeletally immature patients who underwent arthroscopically assisted ACL reconstruction within 3 months of injury. Operative reports and arthroscopic images were reviewed to determine patterns of meniscal injury. The accuracy of preoperative MRI in predicting ACL rupture and meniscus pathology was also compared. One hundred twenty-four patients, including 80 males with an average age of 14.3 years, and 44 females with an average age of 14.1 years were included. The lateral meniscus was torn in 51 patients, the medial meniscus in 17 patients, and both menisci in 19. The prevalence of meniscus tear was 69.3%. Location of the tear occurred in the posterior horn in 69 tears (65.0%), the middle and posterior horn in 31 tears (29.2%), the middle horn in 4 tears (3.7%), and the anterior horn and posterior horn in 2 tears (1.8%). MRI showed 95.6% sensitivity in detecting complete ACL rupture. Further, MRI had a sensitivity of 58.6% and a specificity of 91.3% in characterizing meniscus tears. There are many studies that evaluate ACL rupture in the skeletally immature population, but few studies focus on the meniscus pathology that is associated with these injuries. We reinforce the fact that meniscal injury is commonly associated with ACL rupture in patients with open physes (prevalence of 69.3%). We were able to conclude that lateral meniscus tears are more common than medial meniscus tears, which were equally as common as combined tears in our patient population. The posterior horn is injured in most of patients, and is usually in a repairable configuration and vascular zone. These findings will help to guide surgeons in their clinical evaluation and

  6. Watching Faults Grow in Sand

    NASA Astrophysics Data System (ADS)

    Cooke, M. L.

    2015-12-01

    Accretionary sandbox experiments provide a rich environment for investigating the processes of fault development. These experiments engage students because 1) they enable direct observation of fault growth, which is impossible in the crust (type 1 physical model), 2) they are not only representational but can also be manipulated (type 2 physical model), 3) they can be used to test hypotheses (type 3 physical model) and 4) they resemble experiments performed by structural geology researchers around the world. The structural geology courses at UMass Amherst utilize a series of accretionary sandboxes experiments where students first watch a video of an experiment and then perform a group experiment. The experiments motivate discussions of what conditions they would change and what outcomes they would expect from these changes; hypothesis development. These discussions inevitably lead to calculations of the scaling relationships between model and crustal fault growth and provide insight into the crustal processes represented within the dry sand. Sketching of the experiments has been shown to be a very effective assessment method as the students reveal which features they are analyzing. Another approach used at UMass is to set up a forensic experiment. The experiment is set up with spatially varying basal friction before the meeting and students must figure out what the basal conditions are through the experiment. This experiment leads to discussions of equilibrium and force balance within the accretionary wedge. Displacement fields can be captured throughout the experiment using inexpensive digital image correlation techniques to foster quantitative analysis of the experiments.

  7. State Secret: North Carolina and the Cherokee Trail of Tears

    ERIC Educational Resources Information Center

    Bryant, James

    2008-01-01

    This paper is an analytic essay that examines the treatment of the Cherokee Trail of Tears in a North Carolina fourth grade textbook. I begin by offering a satiric look at an imaginary textbook's treatment of the Holocaust that is based closely on the actual narrative of the Trail of Tears written in the fourth grade text. Following this, close…

  8. A review of surgical repair methods and patient outcomes for gluteal tendon tears.

    PubMed

    Ebert, Jay R; Bucher, Thomas A; Ball, Simon V; Janes, Gregory C

    2015-01-01

    Advanced hip imaging and surgical findings have demonstrated that a common cause of greater trochanteric pain syndrome (GTPS) is gluteal tendon tears. Conservative measures are initially employed to treat GTPS and manage gluteal tears, though patients frequently undergo multiple courses of non-operative treatment with only temporary pain relief. Therefore, a number of surgical treatment options for recalcitrant GTPS associated with gluteal tears have been reported. These have included open trans-osseous or bone anchored suture techniques, endoscopic methods and the use of tendon augmentation for repair reinforcement. This review describes the anatomy, pathophysiology and clinical presentation of gluteal tendon tears. Surgical techniques and patient reported outcomes are presented. This review demonstrates that surgical repair can result in improved patient outcomes, irrespective of tear aetiology, and suggests that the patient with "trochanteric bursitis" should be carefully assessed as newer surgical techniques show promise for a condition that historically has been managed conservatively.

  9. Fault- and Area-Based PSHA in Nepal using OpenQuake: New Insights from the 2015 M7.8 Gorkha-Nepal Earthquake

    NASA Astrophysics Data System (ADS)

    Stevens, Victoria

    2017-04-01

    The 2015 Gorkha-Nepal M7.8 earthquake (hereafter known simply as the Gorkha earthquake) highlights the seismic risk in Nepal, allows better characterization of the geometry of the Main Himalayan Thrust (MHT), and enables comparison of recorded ground-motions with predicted ground-motions. These new data, together with recent paleoseismic studies and geodetic-based coupling models, allow for good parameterization of the fault characteristics. Other faults in Nepal remain less well studied. Unlike previous PSHA studies in Nepal that are exclusively area-based, we use a mix of faults and areas to describe six seismic sources in Nepal. For each source, the Gutenberg-Richter a and b values are found, and the maximum magnitude earthquake estimated, using a combination of earthquake catalogs, moment conservation principals and similarities to other tectonic regions. The MHT and Karakoram fault are described as fault sources, whereas four other sources - normal faulting in N-S trending grabens of northern Nepal, strike-slip faulting in both eastern and western Nepal, and background seismicity - are described as area sources. We use OpenQuake (http://openquake.org/) to carry out the analysis, and peak ground acceleration (PGA) at 2 and 10% chance in 50 years is found for Nepal, along with hazard curves at various locations. We compare this PSHA model with previous area-based models of Nepal. The Main Himalayan Thrust is the principal seismic hazard in Nepal so we study the effects of changing several parameters associated with this fault. We compare ground shaking predicted from various fault geometries suggested from the Gorkha earthquake with each other, and with a simple model of a flat fault. We also show the results from incorporating a coupling model based on geodetic data and microseismicity, which limits the down-dip extent of rupture. There have been no ground-motion prediction equations (GMPEs) developed specifically for Nepal, so we compare the results of

  10. Total IgE and eotaxin (CCL11) contents in tears of patients suffering from seasonal allergic conjunctivitis.

    PubMed

    Eperon, Simone; Berguiga, Marouen; Ballabeni, Pierluigi; Guex-Crosier, Catherine; Guex-Crosier, Yan

    2014-09-01

    To prospectively investigate patients with seasonal allergic conjunctivitis (SAC) during the pollen season and test associations between tears total IgE, eotaxin concentrations, and SAC severity. Enrolled patients presented ocular symptoms and clinical signs of SAC at the time of presentation. Ocular itching, hyperaemia, chemosis, eyelid swelling, and tearing were scored, and the sum of these scores was defined as the clinical score. Conjunctival papillae were separately graded. We measured eotaxin concentration in tears by an enzyme-linked immunosorbent assay (ELISA) and total tear IgE by Lacrytest strip. Among thirty patients (30 eyes), 11 showed neither tear IgE nor tear eotaxin, while 15 out of 19 patients with positive IgE values presented a positive amount of eotaxin in their tears (Fisher's test: p < 0.001). The mean eotaxin concentration was 641 ± 154 (SEM) pg/ml. In patients with no amount of tear IgE, we observed a lower conjunctival papilla grade than in patients whose tears contained some amount of IgE (trend test: p = 0.032). In the 15 patients whose tear eotaxin concentration was null, tear IgE concentration was 5.3 ± 3.5 arbitrary units; in the other 15 patients whose eotaxin was positive, IgE reached 21 ± 4.3 arbitrary U (Mann-Whitney: p < 0.001). We measured 127 ± 47 pg/ml eotaxin in patients with no history of SAC but newly diagnosed as suffering from SAC, and 852 ± 218 pg/ml eotaxin in patients with a known SAC (p = 0.008). In contrast, tear IgE concentrations of both groups did not differ statistically significantly (p = 0.947). If IgE and eotaxin secreted in tears are major contributors in SAC pathogenesis, they however act at different steps of the process.

  11. Fault geometries in basement-induced wrench faulting under different initial stress states

    NASA Astrophysics Data System (ADS)

    Naylor, M. A.; Mandl, G.; Supesteijn, C. H. K.

    Scaled sandbox experiments were used to generate models for relative ages, dip, strike and three-dimensional shape of faults in basement-controlled wrench faulting. The basic fault sequence runs from early en échelon Riedel shears and splay faults through 'lower-angle' shears to P shears. The Riedel shears are concave upwards and define a tulip structure in cross-section. In three dimensions, each Riedel shear has a helicoidal form. The sequence of faults and three-dimensional geometry are rationalized in terms of the prevailing stress field and Coulomb-Mohr theory of shear failure. The stress state in the sedimentary overburden before wrenching begins has a substantial influence on the fault geometries and on the final complexity of the fault zone. With the maximum compressive stress (∂ 1) initially parallel to the basement fault (transtension), Riedel shears are only slightly en échelon, sub-parallel to the basement fault, steeply dipping with a reduced helicoidal aspect. Conversely, with ∂ 1 initially perpendicular to the basement fault (transpression), Riedel shears are strongly oblique to the basement fault strike, have lower dips and an exaggerated helicoidal form; the final fault zone is both wide and complex. We find good agreement between the models and both mechanical theory and natural examples of wrench faulting.

  12. T2 -Mapping evaluation of early cartilage alteration of talus for chronic lateral ankle instability with isolated anterior talofibular ligament tear or combined with calcaneofibular ligament tear.

    PubMed

    Tao, Hongyue; Hu, Yiwen; Qiao, Yang; Ma, Kui; Yan, Xu; Hua, Yinghui; Chen, Shuang

    2018-01-01

    To quantitatively evaluate the cartilage alteration of talus for chronic lateral ankle instability (LAI) with isolated anterior talofibular ligament (ATFL) tear and combined ATFL and calcaneofibular ligament (CFL) tear using T 2 -mapping at 3.0T. In all, 27 patients including 17 with isolated ATFL tear and 10 with ATFL+CFL tear, and 21 healthy subjects were recruited. All participants underwent T 2 -mapping scan at 3T and patients completed American Orthopaedic Foot and Ankle Society (AOFAS) scoring. The total talar cartilage (TTC) was segmented into six compartments: medial anterior (MA), medial center (MC), medial posterior (MP), lateral anterior (LA), lateral center (LC), and lateral posterior (LP). The T 2 value of each compartment was measured from T 2 -mapping images. Data were analyzed with one-way analysis of variance (ANOVA), Student's t-test, and Pearson's correlation coefficient. The T 2 values of MA, MC, MP, TTC in the ATFL group and MA, MC, MP, LC, LP, TTC in the ATFL+CFL group were higher than those in the control group (P < 0.05). Moreover, the T 2 values of MC, MP, LC, and TTC in the ATFL+CFL group were higher than those in the ATFL group (P < 0.05). The T 2 values of MA in both patient groups were negatively correlated with AOFAS scores (r = -0.596, r = -0.690, P < 0.05). Chronic LAI with ATFL tear had a trend of increasing cartilage T 2 values in talar trochlea, mainly involving medial cartilage compartments. Chronic LAI with ATFL+CFL tear might result in higher T 2 values in a much larger cartilage region than with ATFL tear. MA could be the main cartilage compartment that may affect the patient's clinical symptoms. 1 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2018;47:69-77. © 2017 International Society for Magnetic Resonance in Medicine.

  13. Coupled thermal stress simulations of ductile tearing

    DOE PAGES

    Neilsen, Michael K.; Dion, Kristin

    2016-03-01

    Predictions for ductile tearing of a geometrically complex Ti-6Al-4V plate were generated using a Unified Creep Plasticity Damage model in fully coupled thermal stress simulations. Uniaxial tension and butterfly shear tests performed at displacement rates of 0.0254 and 25.4 mm/s were also simulated. Results from these simulations revealed that the material temperature increase due to plastic work can have a dramatic effect on material ductility predictions in materials that exhibit little strain hardening. Furthermore, this occurs because the temperature increase causes the apparent hardening of the material to decrease which leads to the initiation of deformation localization and subsequent ductilemore » tearing earlier in the loading process.« less

  14. Slab rupture and delamination under the Betics and Rif constrained from receiver functions

    NASA Astrophysics Data System (ADS)

    Mancilla, Flor de Lis; Booth-Rea, Guillermo; Stich, Daniel; Pérez-Peña, José Vicente; Morales, José; Azañón, José Miguel; Martin, Rosa; Giaconia, Flavio

    2015-11-01

    We map the lithospheric structure under the westernmost Mediterranean convergent setting interpreting P-receiver functions obtained from a dense seismic network. No orogenic root occurs under the eastern and great part of the central Betics. However, the subducted South Iberian continental lithosphere is found beneath the western Betics where the Iberian Moho reaches depths of approximately 65 km, dipping gently towards the SE. Meanwhile, at the Rif, strong crustal and lithospheric thickness contrasts occur across the Nekor NW-SE sinistral fault that overlies the region of present slab tearing. East of the Nekor fault there is no orogenic root and the crust has been thinned to approximately 22 km, whilst to the west the crust reaches 55 km thickness and the Maghrebian continental lithosphere is attached to the lithospheric slab imaged by tomography under the Alboran basin. These data suggest that subduction rollback under the Alboran and Algerian basins, together with continental slab tearing or detachment producing edge delamination under the Betics and Rif have been the main tectonic mechanisms driving extension, magmatism and regional uplift in the westernmost Mediterranean since the Late Miocene until present. The surface expression of edge-delamination and slab tearing is marked by regional uplift, denudation of HP rocks in elongated core-complex type domes, late Miocene volcanism in the Eastern Betics and Rif, and by large NE-SW strike-slip transfer faults like the Alpujarras, Crevillente, Torcal or Nekor faults that accommodate strong gradients in crustal displacements. The Iberian slab is still attached to the oceanic slab imaged under the Alboran basin at the western Betics where intermediate depth seismicity, recent dextral strike-slip faulting and folding, could reflect slab tearing. Meanwhile, active faulting and differential GPS-measured displacements would mark slab tearing beneath the Rif coinciding with the trace of the sinistral Nekor fault.

  15. A novel remaining tendon preserving repair technique leads to improved outcomes in special rotator cuff tear patterns.

    PubMed

    Jeon, Yoon Sang; Kim, Rag Gyu; Shin, Sang-Jin

    2018-05-16

    The purpose of this study was to identify the tear pattern that could be anatomically repaired by preserving the remaining tendon on footprint and evaluate clinical outcomes of patients who underwent remaining tendon preserving cuff repair. Of 523 patients with full-thickness rotator cuff tears who underwent arthroscopic repair, 41 (7.8%) patients had repairable rotator cuff tear while preserving the remaining tendon. Among them, 31 patients were followed-up for more than 2 years, including 26 patients with posterior L-shaped tear and 5 patients with transtendinous tear patterns. Clinical outcomes were evaluated using ASES and Constant score, SANE score for patient satisfaction, and VAS for pain. MRI was taken for tendon integrity 6 months postoperatively. Of the 31 patients, 11 (35.5%) had previous injury history before rotator cuff tear, including 7 (26.9%) of the 26 patients with posterior L-shaped tear and 4 (80%) of the 5 patients with transtendinous tear. The average size of preoperative cuff tear was 17.8 ± 6.8 mm in anterior-to-posterior direction and 15.2 ± 5.1 mm in medial-to-lateral direction. ASES and Constant score, SANE score, and VAS for pain were significantly (p < 0.001) improved after remaining tendon preserving rotator cuff repair. Rotator cuff tendons of 22(84.6%) patients with posterior L-shaped tear and 4(80%) patients with transtendinous tear patterns were healed. Patients who underwent rotator cuff repair with preservation of the remaining tendon on the footprint obtained satisfactory functional outcomes. Rotator cuff tears in patients who had posterior L-shaped tear extending between supraspinatus and infraspinatus tendons or transtendinous tear pattern with substantial remaining tendon could be repaired using remaining tendon preserving repair technique. Anatomic reduction of torn cuff tendon without undue tension could be achieved using the remaining tendon preserving repair technique.

  16. Fault Gauge Numerical Simulation : Dynamic Rupture Propagation and Local Energy Partitioning

    NASA Astrophysics Data System (ADS)

    Mollon, G.

    2017-12-01

    In this communication, we present dynamic simulations of the local (centimetric) behaviour of a fault filled with a granular gauge submitted to dynamic rupture. The numerical tool (Fig. 1) combines classical Discrete Element Modelling (albeit with the ability to deal with arbitrary grain shapes) for the simualtion of the gauge, and continuous modelling for the simulation of the acoustic waves emission and propagation. In a first part, the model is applied to the simulation of steady-state shearing of the fault under remote displacement boudary conditions, in order to observe the shear accomodation at the interface (R1 cracks, localization, wear, etc.). It also makes it possible to fit to desired values the Rate and State Friction properties of the granular gauge by adapting the contact laws between grains. Such simulations provide quantitative insight in the steady-state energy partitionning between fracture, friction and acoustic emissions as a function of the shear rate. In a second part, the model is submitted to dynamic rupture. For that purpose, the fault is elastically preloaded just below rupture, and a displacement pulse is applied at one end of the sample (and on only one side of the fault). This allows to observe the propagation of the instability along the fault and the interplay between this propagation and the local granular phenomena. Energy partitionning is then observed both in space and time.

  17. Detection of prosecretory mitogen lacritin in nonprimate tears primarily as a C-terminal-like fragment.

    PubMed

    Laurie, Diane E; Splan, Rebecca K; Green, Kari; Still, Katherine M; McKown, Robert L; Laurie, Gordon W

    2012-09-12

    Lacritin is a human tear glycoprotein that promotes basal tear protein secretion in cultured rat lacrimal acinar cells and proliferation of subconfluent human corneal epithelial cells. When topically added to rabbit eyes, lacritin promotes basal tearing. Despite these activities on several species, lacritin's presence in nonprimate tears or other tissues has not been explored. Here we probed for lacritin in normal horse tears. Sequences were collected from the Ensembl genomic alignment of human LACRT gene with high-quality draft horse genome (EquCab2.0) and analyzed. Normal horse tears were collected and assayed by Western blotting, ELISA, and mass spectrometry. Newly generated rabbit antibodies, respectively, against N- and C-terminal regions of human lacritin were employed. Identity was 75% and 45%, respectively, at nucleotide and protein levels. Structural features were conserved, including a C-terminal amphipathic α-helix. Anti-C-terminal antibodies strongly detected a ∼13 kDa band in horse tears that was validated by mass spectrometry. In human tears, the same antibody detected uncleaved lacritin (∼24 kDa) strongly and C-terminal fragments of ∼13 and ∼11 kDa weakly. Anti-N-terminal antibodies were slightly reactive with a ∼24 kDa horse antigen and showed no reaction with the anti-C-terminal-reactive ∼13 kDa species. Similar respective levels of horse C-terminal versus N-terminal immunoreactivity were apparent by ELISA. Lacritin is present in horse tears, largely as a C-terminal fragment homologous to the mitogenic and bactericidal region in human lacritin, suggesting potential benefit in corneal wound repair.

  18. Do Magnetic Resonance Imaging Characteristics of Full-Thickness Rotator Cuff Tears Correlate With Sleep Disturbance?

    PubMed

    Reyes, Bryan A; Hull, Brandon R; Kurth, Alexander B; Kukowski, Nathan R; Mulligan, Edward P; Khazzam, Michael S

    2017-11-01

    Many patients with rotator cuff tears suffer from nocturnal shoulder pain, resulting in sleep disturbance. To determine whether rotator cuff tear size correlated with sleep disturbance in patients with full-thickness rotator cuff tears. Cross-sectional study; Level of evidence, 3. Patients with a diagnosis of unilateral full-thickness rotator cuff tears (diagnosed via magnetic resonance imaging [MRI]) completed the Pittsburgh Sleep Quality Index (PSQI), a visual analog scale (VAS) quantifying their shoulder pain, and the American Shoulder and Elbow Surgeons (ASES) questionnaire. Shoulder MRI scans were analyzed for anterior-posterior tear size (mm), tendon retraction (mm), Goutallier grade (0-4), number of tendons involved (1-4), muscle atrophy (none, mild, moderate, or severe), and humeral head rise (present or absent). Bivariate correlations were calculated between the MRI characteristics and baseline survey results. A total of 209 patients with unilateral full-thickness rotator cuff tears were included in this study: 112 (54%) female and 97 (46%) male (mean age, 64.1 years). On average, shoulder pain had been present for 24 months. The mean PSQI score was 9.8, and the mean VAS score was 5.0. No significant correlations were found between any of the rotator cuff tear characteristics and sleep quality. Only tendon retraction had a significant correlation with pain. Although rotator cuff tears are frequently associated with nocturnal pain and sleep disruption, this study demonstrated that morphological characteristics of full-thickness rotator cuff tears, such as size and tendon retraction, do not correlate with sleep disturbance and have little to no correlation with pain levels.

  19. Tear clearance and ocular symptoms in patients treated with preservative-free prostaglandins.

    PubMed

    Giménez-Gómez, R; García-Catalán, M R; Gallardo-Galera, J M

    2013-03-01

    To assess the effects on dry eye symptoms and tear dynamics of switching from a prostaglandin with a preservative to a preservative-free prostaglandin. Fourteen patients (N=28 eyes) with open-angle glaucoma and dry eye symptons, treated with preserved latanoprost, travoprost or bimatoprost were included in this uncontrolled prospective study. Ocular symptoms were analysed using a validated ocular surface disease questionnaire and ocular signs were assessed with tear clearance, Schirmer and tear function index test (TFI=Schirmer/clearance). Patients were assigned to preservative-free tafluprost treatment, and measurements were repeated 4 weeks after change of medication. Wilcoxon test and Spearman correlation coefficient were used in the statistical analysis. No statistically significant difference in intraocular pressure (IOP) was observed after switching to tafluprost. Mean IOP at baseline was 20.4 mmHg (SD2.2) and after 4 weeks 19.9 mmHg (SD2.6), (P>.05). The mean questionnaire score significantly decreased from 9.7 (SD3.7) at baseline to 5.4 (SD2.7) after one month (P<.001). No significant differences in tear clearance, Schirmer or TFI were found (P>.05). At baseline, tear clearance=0.13 (SD0.07), Schirmer=10.7 mm (SD6) and TFI=80 (48-156). After 4 weeks, tear clearance=0.1(SD0.07), Schirmer=9.5 mm (3.9) and TFI=104 (48-216). A significant association between questionnaire score and tear clearance after 4 weeks was observed (Spearman coefficient=0.62; P=.014). Switching from preservative prostaglandin with a preservative to preservative-free tafluprost treatment improves dry eye symptoms and suggests an improvement in TFI. Copyright © 2012 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  20. Evaluation of outgassing, tear strength, and detail reproduction in alginate substitute materials.

    PubMed

    Baxter, R T; Lawson, N C; Cakir, D; Beck, P; Ramp, L C; Burgess, J O

    2012-01-01

    To compare three alginate substitute materials to an alginate impression material for cast surface porosity (outgassing), tear strength, and detail reproduction. Detail reproduction tests were performed following American National Standards Institute/American Dental Association (ANSI/ADA) Specification No. 19. To measure tear strength, 12 samples of each material were made using a split mold, placed in a water bath until testing, and loaded in tension until failure at a rate of 500 mm/min using a universal testing machine. For cast surface porosity testing, five impressions of a Teflon mold with each material were placed in a water bath (37.8°C) for the in-mouth setting time and poured with vacuum-mixed Silky Rock die stone at 5, 10, 30, and 60 minutes from the start of mixing. The gypsum samples were analyzed with a digital microscope for surface porosity indicative of hydrogen gas release by comparing the surface obtained at each interval with four casts representing no, little, some, and significant porosity. Data analysis was performed using parametric and Kruskal-Wallis analysis of variance (ANOVA), Tukey/Kramer post-hoc tests (α=0.05), and individual Mann-Whitney U tests (α=0.0167). All alginate substitute materials passed the detail reproduction test. Tear strength of the alginate substitute materials was significantly better than alginate and formed three statistically different groups: AlgiNot had the lowest tear strength, Algin-X Ultra had the highest tear strength, and Position Penta Quick had intermediate tear strength. Significant variation in outgassing existed between materials and pouring times (p<0.05). All alginate substitute materials exhibited the least outgassing and cast porosity 60 minutes after mixing. Detail reproduction and tear strength of alginate substitute materials were superior to traditional alginate. The outgassing effect was minimal for most materials tested. Alginate substitute materials are superior replacements for

  1. Analyses of Buckling and Stable Tearing in Thin-Sheet Materials

    NASA Technical Reports Server (NTRS)

    Seshadri, B. R.; Newman, J. C., Jr.

    1998-01-01

    This paper was to verify the STAGS (general shell, geometric and material nonlinear) code and the critical crack tip opening angle (CTOA) fracture criterion for predicting stable tearing in cracked panels that fail with severe out of plane buckling. Materials considered ranged from brittle to ductile behavior. Test data used in this study are reported elsewhere. The STAGS code was used to model stable tearing using a critical CTOA value that was determined from a cracked panel that was 'restrained' from buckling. ne analysis methodology was then used to predict the influence of buckling on stable tearing and failure loads. Parameters like crack length to specimen width ratio, crack configuration, thickness, and material tensile properties had a significant influence on the buckling behavior of cracked thin sheet materials. Experimental and predicted results showed a varied buckling response for different crack length to sheet thickness ratios because different buckling modes were activated. Effects of material tensile properties and fracture toughness on buckling response were presented. The STAGS code and the CTOA fracture criterion were able to predict the influence of buckling on stable tearing behavior and failure loads on a variety of materials and crack configurations.

  2. Fault zone hydrogeologic properties and processes revealed by borehole temperature monitoring

    NASA Astrophysics Data System (ADS)

    Fulton, P. M.; Brodsky, E. E.

    2015-12-01

    High-resolution borehole temperature monitoring can provide valuable insight into the hydrogeologic structure of fault zones and transient processes that affect fault zone stability. Here we report on results from a subseafloor temperature observatory within the Japan Trench plate boundary fault. In our efforts to interpret this unusual dataset, we have developed several new methods for probing hydrogeologic properties and processes. We illustrate how spatial variations in the thermal recovery of the borehole after drilling and other spectral characteristics provide a measure of the subsurface permeability architecture. More permeable zones allow for greater infiltration of cool drilling fluids, are more greatly thermally disturbed, and take longer to recover. The results from the JFAST (Japan Trench Fast Drilling Project) observatory are consistent with geophysical logs, core data, and other hydrologic observations and suggest a permeable damage zone consisting of steeply dipping faults and fractures overlays a low-permeability clay-rich plate boundary fault. Using high-resolution time series data, we have also developed methods to map out when and where fluid advection occurs in the subsurface over time. In the JFAST data, these techniques reveal dozens of transient earthquake-driven fluid pulses that are spatially correlated and consistently located around inferred permeable areas of the fault damage zone. These observations are suspected to reflect transient fluid flow driven by pore pressure changes in response to dynamic and/or static stresses associated with nearby earthquakes. This newly recognized hydrologic phenomenon has implications for understanding subduction zone heat and chemical transport as well as the redistribution of pore fluid pressure which influences fault stability and can trigger other earthquakes.

  3. Glycomic characterization of basal tears and changes with diabetes and diabetic retinopathy.

    PubMed

    Nguyen-Khuong, Terry; Everest-Dass, Arun V; Kautto, Liisa; Zhao, Zhenjun; Willcox, Mark D P; Packer, Nicolle H

    2015-03-01

    As a secreted fluid, the state of tear glycosylation is particularly important in the role of immunity of the ocular surface. Tears are a valuable source of non-invasive biomarkers for disease and there are continued efforts to characterize their components thoroughly. In this study, a small volume of basal tears (5 μL) was collected from healthy controls, patients with diabetes without retinopathy and patients with diabetes and retinopathy. The detailed N- and O-linked tear protein glycome was characterized and the relative abundance of each structure determined. Of the 50 N-linked glycans found, 89% were complex with 50% containing a bisecting N-acetylglucosamine, 65% containing a core fucose whilst 33% were sialylated. Of the 8 O-linked glycans detected, 3 were of cores 1 and 5 of core 2 type, with a majority of them being sialylated (90%). Additionally, these glycan structures were profiled across the three diabetic disease groups. Whilst the higher abundant structures did not alter across the three groups, only five low abundance N-linked glycans and 1 O-linked glycan did alter with the onset of diabetes mellitus and diabetic retinopathy (DR). These results suggest the conservation of glycan types on basal tear proteins between individuals and point to only small changes in glycan expression on the proteins in tears with the development of diabetes and DR. © The Author 2014. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  4. New insights on stress rotations from a forward regional model of the San Andreas fault system near its Big Bend in southern California

    USGS Publications Warehouse

    Fitzenz, D.D.; Miller, S.A.

    2004-01-01

    Understanding the stress field surrounding and driving active fault systems is an important component of mechanistic seismic hazard assessment. We develop and present results from a time-forward three-dimensional (3-D) model of the San Andreas fault system near its Big Bend in southern California. The model boundary conditions are assessed by comparing model and observed tectonic regimes. The model of earthquake generation along two fault segments is used to target measurable properties (e.g., stress orientations, heat flow) that may allow inferences on the stress state on the faults. It is a quasi-static model, where GPS-constrained tectonic loading drives faults modeled as mostly sealed viscoelastic bodies embedded in an elastic half-space subjected to compaction and shear creep. A transpressive tectonic regime develops southwest of the model bend as a result of the tectonic loading and migrates toward the bend because of fault slip. The strength of the model faults is assessed on the basis of stress orientations, stress drop, and overpressures, showing a departure in the behavior of 3-D finite faults compared to models of 1-D or homogeneous infinite faults. At a smaller scale, stress transfers from fault slip transiently induce significant perturbations in the local stress tensors (where the slip profile is very heterogeneous). These stress rotations disappear when subsequent model earthquakes smooth the slip profile. Maps of maximum absolute shear stress emphasize both that (1) future models should include a more continuous representation of the faults and (2) that hydrostatically pressured intact rock is very difficult to break when no material weakness is considered. Copyright 2004 by the American Geophysical Union.

  5. Fault zone property near Xinfengjiang Reservoir using dense, across-fault seismic array

    NASA Astrophysics Data System (ADS)

    Lee, M. H. B.; Yang, H.; Sun, X.

    2017-12-01

    Properties of fault zones are important to the understanding of earthquake process. Around the fault zone is a damaged zone which is characterised by a lower seismic velocity. This is detectable as a low velocity zone and measure some physical property of the fault zone, which is otherwise difficult sample directly. A dense, across-fault array of short period seismometer is deployed on an inactive fault near Xinfengjiang Reservoir. Local events were manually picked. By computing the synthetic arrival time, we were able to constrain the parameters of the fault zone Preliminary result shows that the fault zone is around 350 m wide with a P and S velocity increase of around 10%. The fault is geologically inferred, and this result suggested that it may be a geological layer. The other possibility is that the higher velocity is caused by a combination of fault zone healing and fluid intrusion. Whilst the result was not able to tell us the nature of the fault, it demonstrated that this method is able to derive properties from a fault zone.

  6. Evaluation of aqueous tear production in dogs after general anaesthesia with medetomidine-propofol-carprofen-halothane.

    PubMed

    Komnenou, A T H; Kazakos, G M; Savvas, I; Thomas, A L N

    2013-08-10

    The influence of an anaesthetic protocol, which included medetomidine, propofol, carprofen and halothane on tear production in the dog. There are no previous studies on the effects of this combination on tear production in dogs or in any other species. The present study included 39 dogs, which underwent non-ophthalmic surgery in our clinic. Preanaesthetically, all dogs had normal tear production (18.62±3.65 mm/minute) as this was recorded with Schirmer tear test I (STT I) and the ophthalmologic examination did not reveal anything abnormal. Tear production readings were recorded before the administration of premedication, at the end of anaesthesia, one hour and two hours postanaesthesia. No reverse agent was administrated. At the end of anaesthesia (right eye (oculus dexter, OD) P<0.0005, left eye (oculus sinister, OS) P<0.0005), as well as one hour postanaesthesia (OD P=0.020, OS P=0.001) there was a statistically significant reduction in tear production, which returned to normal values two hours postanaesthesia, regardless of the duration of the operation. This anaesthetic combination resulted in a decrease in tear production and, therefore, the use of tear substitute treatment in dogs undergoing anaesthesia with this protocol (combination) from the time the sedative is given until at least two hours after the end of anaesthesia is highly recommended.

  7. Rotator cuff muscle degeneration and tear severity related to myogenic, adipogenic, and atrophy genes in human muscle.

    PubMed

    Shah, Shivam A; Kormpakis, Ioannis; Cavinatto, Leonardo; Killian, Megan L; Thomopoulos, Stavros; Galatz, Leesa M

    2017-12-01

    Large rotator cuff tear size and advanced muscle degeneration can affect reparability of tears and compromise tendon healing. Clinicians often rely on direct measures of rotator cuff tear size and muscle degeneration from magnetic resonance imaging (MRI) to determine whether the rotator cuff tear is repairable. The objective of this study was to identify the relationship between gene expression changes in rotator cuff muscle degeneration to standard data available to clinicians. Radiographic assessment of preoperative rotator cuff tear severity was completed for 25 patients with varying magnitudes of rotator cuff tears. Tear width and retraction were measured using MRI, and Goutallier grade, tangent (tan) sign, and Thomazeau grade were determined. Expression of myogenic-, adipogenic-, atrophy-, and metabolism-related genes in biopsied muscles were correlated with tear width, tear retraction, Goutallier grade, tan sign, and Thomazeau grade. Tear width positively correlated with Goutallier grade in both the supraspinatus (r = 0.73) and infraspinatus (r = 0.77), along with tan sign (r = 0.71) and Thomazeau grade (r = 0.68). Decreased myogenesis (Myf5), increased adipogenesis (CEBPα, Lep, Wnt10b), and decreased metabolism (PPARα) correlated with radiographic assessments. Gene expression changes suggest that rotator cuff tears lead to a dramatic molecular response in an attempt to maintain normal muscle tissue, increase adipogenesis, and decrease metabolism. Fat accumulation and muscle atrophy appear to stem from endogenous changes rather than from changes mediated by infiltrating cells. Results suggest that chronic unloading of muscle, induced by rotator cuff tear, disrupts muscle homeostasis. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2808-2814, 2017. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  8. Evolving transpressional strain fields along the San Andreas fault in southern California: implications for fault branching, fault dip segmentation and strain partitioning

    NASA Astrophysics Data System (ADS)

    Bergh, Steffen; Sylvester, Arthur; Damte, Alula; Indrevær, Kjetil

    2014-05-01

    The San Andreas fault in southern California records only few large-magnitude earthquakes in historic time, and the recent activity is confined primarily on irregular and discontinuous strike-slip and thrust fault strands at shallow depths of ~5-20 km. Despite this fact, slip along the San Andreas fault is calculated to c. 35 mm/yr based on c.160 km total right lateral displacement for the southern segment of the fault in the last c. 8 Ma. Field observations also reveal complex fault strands and multiple events of deformation. The presently diffuse high-magnitude crustal movements may be explained by the deformation being largely distributed along more gently dipping reverse faults in fold-thrust belts, in contrast to regions to the north where deformation is less partitioned and localized to narrow strike-slip fault zones. In the Mecca Hills of the Salton trough transpressional deformation of an uplifted segment of the San Andreas fault in the last ca. 4.0 My is expressed by very complex fault-oblique and fault-parallel (en echelon) folding, and zones of uplift (fold-thrust belts), basement-involved reverse and strike-slip faults and accompanying multiple and pervasive cataclasis and conjugate fracturing of Miocene to Pleistocene sedimentary strata. Our structural analysis of the Mecca Hills addresses the kinematic nature of the San Andreas fault and mechanisms of uplift and strain-stress distribution along bent fault strands. The San Andreas fault and subsidiary faults define a wide spectrum of kinematic styles, from steep localized strike-slip faults, to moderate dipping faults related to oblique en echelon folds, and gently dipping faults distributed in fold-thrust belt domains. Therefore, the San Andreas fault is not a through-going, steep strike-slip crustal structure, which is commonly the basis for crustal modeling and earthquake rupture models. The fault trace was steep initially, but was later multiphase deformed/modified by oblique en echelon folding

  9. Rule-based fault diagnosis of hall sensors and fault-tolerant control of PMSM

    NASA Astrophysics Data System (ADS)

    Song, Ziyou; Li, Jianqiu; Ouyang, Minggao; Gu, Jing; Feng, Xuning; Lu, Dongbin

    2013-07-01

    Hall sensor is widely used for estimating rotor phase of permanent magnet synchronous motor(PMSM). And rotor position is an essential parameter of PMSM control algorithm, hence it is very dangerous if Hall senor faults occur. But there is scarcely any research focusing on fault diagnosis and fault-tolerant control of Hall sensor used in PMSM. From this standpoint, the Hall sensor faults which may occur during the PMSM operating are theoretically analyzed. According to the analysis results, the fault diagnosis algorithm of Hall sensor, which is based on three rules, is proposed to classify the fault phenomena accurately. The rotor phase estimation algorithms, based on one or two Hall sensor(s), are initialized to engender the fault-tolerant control algorithm. The fault diagnosis algorithm can detect 60 Hall fault phenomena in total as well as all detections can be fulfilled in 1/138 rotor rotation period. The fault-tolerant control algorithm can achieve a smooth torque production which means the same control effect as normal control mode (with three Hall sensors). Finally, the PMSM bench test verifies the accuracy and rapidity of fault diagnosis and fault-tolerant control strategies. The fault diagnosis algorithm can detect all Hall sensor faults promptly and fault-tolerant control algorithm allows the PMSM to face failure conditions of one or two Hall sensor(s). In addition, the transitions between health-control and fault-tolerant control conditions are smooth without any additional noise and harshness. Proposed algorithms can deal with the Hall sensor faults of PMSM in real applications, and can be provided to realize the fault diagnosis and fault-tolerant control of PMSM.

  10. The susitna glacier thrust fault: Characteristics of surface ruptures on the fault that initiated the 2002 denali fault earthquake

    USGS Publications Warehouse

    Crone, A.J.; Personius, S.F.; Craw, P.A.; Haeussler, P.J.; Staft, L.A.

    2004-01-01

    The 3 November 2002 Mw 7.9 Denali fault earthquake sequence initiated on the newly discovered Susitna Glacier thrust fault and caused 48 km of surface rupture. Rupture of the Susitna Glacier fault generated scarps on ice of the Susitna and West Fork glaciers and on tundra and surficial deposits along the southern front of the central Alaska Range. Based on detailed mapping, 27 topographic profiles, and field observations, we document the characteristics and slip distribution of the 2002 ruptures and describe evidence of pre-2002 ruptures on the fault. The 2002 surface faulting produced structures that range from simple folds on a single trace to complex thrust-fault ruptures and pressure ridges on multiple, sinuous strands. The deformation zone is locally more than 1 km wide. We measured a maximum vertical displacement of 5.4 m on the south-directed main thrust. North-directed backthrusts have more than 4 m of surface offset. We measured a well-constrained near-surface fault dip of about 19?? at one site, which is considerably less than seismologically determined values of 35??-48??. Surface-rupture data yield an estimated magnitude of Mw 7.3 for the fault, which is similar to the seismological value of Mw 7.2. Comparison of field and seismological data suggest that the Susitna Glacier fault is part of a large positive flower structure associated with northwest-directed transpressive deformation on the Denali fault. Prehistoric scarps are evidence of previous rupture of the Sustina Glacier fault, but additional work is needed to determine if past failures of the Susitna Glacier fault have consistently induced rupture of the Denali fault.

  11. Examination of tear film smoothness on corneae after refractive surgeries using a noninvasive interferometric method

    NASA Astrophysics Data System (ADS)

    Szczesna, Dorota H.; Kulas, Zbigniew; Kasprzak, Henryk T.; Stenevi, Ulf

    2009-11-01

    A lateral shearing interferometer was used to examine the smoothness of the tear film. The information about the distribution and stability of the precorneal tear film is carried out by the wavefront reflected from the surface of tears and coded in interference fringes. Smooth and regular fringes indicate a smooth tear film surface. On corneae after laser in situ keratomileusis (LASIK) or radial keratotomy (RK) surgery, the interference fringes are seldom regular. The fringes are bent on bright lines, which are interpreted as tear film breakups. The high-intensity pattern seems to appear in similar location on the corneal surface after refractive surgery. Our purpose was to extract information about the pattern existing under the interference fringes and calculate its shape reproducibility over time and following eye blinks. A low-pass filter was applied and correlation coefficient was calculated to compare a selected fragment of the template image to each of the following frames in the recorded sequence. High values of the correlation coefficient suggest that irregularities of the corneal epithelium might influence tear film instability and that tear film breakup may be associated with local irregularities of the corneal topography created after the LASIK and RK surgeries.

  12. Different patterns of lateral meniscus root tears in ACL injuries: application of a differentiated classification system.

    PubMed

    Forkel, Philipp; Reuter, Sven; Sprenker, Frederike; Achtnich, Andrea; Herbst, Elmar; Imhoff, Andreas; Petersen, Wolf

    2015-01-01

    Posterior lateral meniscus root tears (PLMRTs) affect the intra-articular pressure distribution in the lateral compartment of the knee. The biomechanical consequences of these injuries are significantly influenced by the integrity of the meniscofemoral ligaments (MFLs). A newly introduced arthroscopic classification system for PLMRTs that takes MFL integrity into account has not yet been clinically applied but may be useful in selecting the optimal method of PLMRT repair. Prospective ACL reconstruction data were collected. Concomitant injuries of the lateral meniscus posterior horn were classified according to their shape and MFL status. The classifications were: type 1, avulsion of the root; type 2, radial tear of the lateral meniscus posterior horn close to the root with an intact MFL; and type 3, complete detachment of the posterior meniscus horn. Between January 2011 and May 2012, 228 consecutive ACL reconstructions were included. Lateral and medial meniscus tears were identified in 38.2% (n = 87) and 44.7% (n = 102), respectively. Of the 87 lateral meniscus tears, 32 cases had PLMRTs; the overall prevalence of PLMRTs was 14% (n = 32). Two medial meniscus root tears were detected. All PLMRTs were classified according to the classification system described above, and the fixation procedure was adapted to the type of meniscus tear. The PLMRT tear is a common injury among patients undergoing ACL repair and can be arthroscopically classified into three different types. Medial meniscus root tears are rare in association with ACL tears. The PLMRT classification presented here may help to estimate the injury's impact on the lateral compartment and to identify the optimal treatment. These tears should not be overlooked, and the treatment strategy should be chosen with respect to the type of root tear. IV.

  13. Detection of partial-thickness tears in ligaments and tendons by Stokes-polarimetry imaging

    NASA Astrophysics Data System (ADS)

    Kim, Jihoon; John, Raheel; Walsh, Joseph T.

    2008-02-01

    A Stokes polarimetry imaging (SPI) system utilizes an algorithm developed to construct degree of polarization (DoP) image maps from linearly polarized light illumination. Partial-thickness tears of turkey tendons were imaged by the SPI system in order to examine the feasibility of the system to detect partial-thickness rotator cuff tear or general tendon pathology. The rotating incident polarization angle (IPA) for the linearly polarized light provides a way to analyze different tissue types which may be sensitive to IPA variations. Degree of linear polarization (DoLP) images revealed collagen fiber structure, related to partial-thickness tears, better than standard intensity images. DoLP images also revealed structural changes in tears that are related to the tendon load. DoLP images with red-wavelength-filtered incident light may show tears and related organization of collagen fiber structure at a greater depth from the tendon surface. Degree of circular polarization (DoCP) images exhibited well the horizontal fiber orientation that is not parallel to the vertically aligned collagen fibers of the tendon. The SPI system's DOLP images reveal alterations in tendons and ligaments, which have a tissue matrix consisting largely of collagen, better than intensity images. All polarized images showed modulated intensity as the IPA was varied. The optimal detection of the partial-thickness tendon tears at a certain IPA was observed. The SPI system with varying IPA and spectral information can improve the detection of partial-thickness rotator cuff tears by higher visibility of fiber orientations and thereby improve diagnosis and treatment of tendon related injuries.

  14. New insights on active fault geometries in the Mentawai region of Sumatra, Indonesia, from broadband waveform modeling of earthquake source parameters

    NASA Astrophysics Data System (ADS)

    WANG, X.; Wei, S.; Bradley, K. E.

    2017-12-01

    Global earthquake catalogs provide important first-order constraints on the geometries of active faults. However, the accuracies of both locations and focal mechanisms in these catalogs are typically insufficient to resolve detailed fault geometries. This issue is particularly critical in subduction zones, where most great earthquakes occur. The Slab 1.0 model (Hayes et al. 2012), which was derived from global earthquake catalogs, has smooth fault geometries, and cannot adequately address local structural complexities that are critical for understanding earthquake rupture patterns, coseismic slip distributions, and geodetically monitored interseismic coupling. In this study, we conduct careful relocation and waveform modeling of earthquake source parameters to reveal fault geometries in greater detail. We take advantage of global data and conduct broadband waveform modeling for medium size earthquakes (M>4.5) to refine their source parameters, which include locations and fault plane solutions. The refined source parameters can greatly improve the imaging of fault geometry (e.g., Wang et al., 2017). We apply these approaches to earthquakes recorded since 1990 in the Mentawai region offshore of central Sumatra. Our results indicate that the uncertainty of the horizontal location, depth and dip angle estimation are as small as 5 km, 2 km and 5 degrees, respectively. The refined catalog shows that the 2005 and 2009 "back-thrust" sequences in Mentawai region actually occurred on a steeply landward-dipping fault, contradicting previous studies that inferred a seaward-dipping backthrust. We interpret these earthquakes as `unsticking' of the Sumatran accretionary wedge along a backstop fault that separates accreted material of the wedge from the strong Sunda lithosphere, or reactivation of an old normal fault buried beneath the forearc basin. We also find that the seismicity on the Sunda megathrust deviates in location from Slab 1.0 by up to 7 km, with along strike

  15. The Diagnostic Accuracy of Special Tests for Rotator Cuff Tear: The ROW Cohort Study

    PubMed Central

    Jain, Nitin B.; Luz, Jennifer; Higgins, Laurence D.; Dong, Yan; Warner, Jon J.P.; Matzkin, Elizabeth; Katz, Jeffrey N.

    2016-01-01

    Objective The aim was to assess diagnostic accuracy of 15 shoulder special tests for rotator cuff tears. Design From 02/2011 to 12/2012, 208 participants with shoulder pain were recruited in a cohort study. Results Among tests for supraspinatus tears, Jobe’s test had a sensitivity of 88% (95% CI=80% to 96%), specificity of 62% (95% CI=53% to 71%), and likelihood ratio of 2.30 (95% CI=1.79 to 2.95). The full can test had a sensitivity of 70% (95% CI=59% to 82%) and a specificity of 81% (95% CI=74% to 88%). Among tests for infraspinatus tears, external rotation lag signs at 0° had a specificity of 98% (95% CI=96% to 100%) and a likelihood ratio of 6.06 (95% CI=1.30 to 28.33), and the Hornblower’s sign had a specificity of 96% (95% CI=93% to 100%) and likelihood ratio of 4.81 (95% CI=1.60 to 14.49). Conclusions Jobe’s test and full can test had high sensitivity and specificity for supraspinatus tears and Hornblower’s sign performed well for infraspinatus tears. In general, special tests described for subscapularis tears have high specificity but low sensitivity. These data can be used in clinical practice to diagnose rotator cuff tears and may reduce the reliance on expensive imaging. PMID:27386812

  16. Acute Tears of the Tibialis Posterior Tendon Following Ankle Sprain.

    PubMed

    Jackson, Lyle T; Dunaway, Linda J; Lundeen, Gregory A

    2017-07-01

    Traumatic tears of the tibialis posterior (TP) tendon following an ankle sprain are rare. The purpose of this study was to report our case series of TP tendon tears following an ankle sprain. Patients with persistent TP tendon pain after an ankle sprain were retrospectively identified over a 4-year period and reviewed. A comparison of magnetic resonance imaging (MRI) interpretations by a radiologist and surgeon was made. Patients failing conservative management underwent operative repair of the TP tendon tear and concomitant pathology. Failure of the index surgery was defined as TP tendinosis, which was treated with excision and flexor digitorum longus tendon transfer. Outcomes were measured with the Foot Function Index (FFI) and American Orthopaedic Foot & Ankle Society (AOFAS) hindfoot scores. Thirteen patients were found to have a TP tendon tear following an ankle sprain. The incidence for TP tears with sprains presented to our clinic was 1.04%. MRI identified TP tendon pathology in 4 patients by a radiologist review and in 11 patients by a surgeon review. The most common concomitant pathology was a talar osteochondral defect in 13 of 13 patients and ligament instability in 12 of 13 patients (5/13 lateral, 3/13 medial, 4/13 multidirectional instability). Four of 13 patients failed the index surgery. Of the 9 remaining patients, 4 had clinical follow-up at an average of 4.6 years postoperatively. The average FFI subscale scores were the following: pain, 40.4; disability, 28.9; and activity, 23.6. The average AOFAS hindfoot score was 68.8. Despite being rare, a TP tendon tear should be included in the differential diagnosis for persistent medial-sided pain following an ankle sprain. MRI findings can be subtle. Associated pathology was very common and likely confounded the diagnosis and outcomes. Patients should be counseled on the possibility of poor outcomes and long-term pain. Level IV, case series.

  17. dc Arc Fault Effect on Hybrid ac/dc Microgrid

    NASA Astrophysics Data System (ADS)

    Fatima, Zahra

    The advent of distributed energy resources (DER) and reliability and stability problems of the conventional grid system has given rise to the wide spread deployment of microgrids. Microgrids provide many advantages by incorporating renewable energy sources and increasing the reliability of the grid by isolating from the main grid in case of an outage. AC microgrids have been installed all over the world, but dc microgrids have been gaining interest due to the advantages they provide over ac microgrids. However the entire power network backbone is still ac and dc microgrids require expensive converters to connect to the ac power network. As a result hybrid ac/dc microgrids are gaining more attention as it combines the advantages of both ac and dc microgrids such as direct integration of ac and dc systems with minimum number of conversions which increases the efficiency by reducing energy losses. Although dc electric systems offer many advantages such as no synchronization and no reactive power, successful implementation of dc systems requires appropriate protection strategies. One unique protection challenge brought by the dc systems is dc arc faults. A dc arc fault is generated when there is a gap in the conductor due to insulation degradation and current is used to bridge the gap, resulting in an arc with very high temperature. Such a fault if it goes undetected and is not extinguished can cause damage to the entire system and cause fires. The purpose of the research is to study the effect of the dc arc fault at different locations in the hybrid ac/dc microgrid and provide insight on the reliability of the grid components when it is impacted by arc faults at various locations in the grid. The impact of dc arc fault at different locations on the performance of the PV array, wind generation, and constant power loads (CPL) interfaced with dc/dc converters is studied. MATLAB/Simulink is used to model the hybrid ac/dc microgrid and arc fault.

  18. Interaction of lysozyme with a tear film lipid layer model: A molecular dynamics simulation study.

    PubMed

    Wizert, Alicja; Iskander, D Robert; Cwiklik, Lukasz

    2017-12-01

    The tear film is a thin multilayered structure covering the cornea. Its outermost layer is a lipid film underneath of which resides on an aqueous layer. This tear film lipid layer (TFLL) is itself a complex structure, formed by both polar and nonpolar lipids. It was recently suggested that due to tear film dynamics, TFLL contains inhomogeneities in the form of polar lipid aggregates. The aqueous phase of tear film contains lachrymal-origin proteins, whereby lysozyme is the most abundant. These proteins can alter TFLL properties, mainly by reducing its surface tension. However, a detailed nature of protein-lipid interactions in tear film is not known. We investigate the interactions of lysozyme with TFLL in molecular details by employing coarse-grained molecular dynamics simulations. We demonstrate that lysozyme, due to lateral restructuring of TFLL, is able to penetrate the tear lipid film embedded in inverse micellar aggregates. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Palaeopermeability anisotropies of a strike-slip fault damage zone: 3D Insights of quantitative fluid flow from µCT analysis.

    NASA Astrophysics Data System (ADS)

    Gomila, R.; Arancibia, G.; Nehler, M.; Bracke, R.; Morata, D.

    2017-12-01

    Fault zones and their related structural permeability are a key aspect in the migration of fluids through the continental crust. Therefore, the estimation of the hydraulic properties (palaeopermeability conditions; k) and the spatial distribution of the fracture mesh within the damage zone (DZ) are critical in the assessment of fault zones behavior for fluids. The study of the real spatial distribution of the veinlets of the fracture mesh (3D), feasible with the use of µCT analyses, is a first order factor to unravel both, the real structural permeability conditions of a fault-zone, and the validation of previous (and classical) estimations made in 2D analyses in thin-sections. This work shows the results of a fault-related fracture mesh and its 3D spatial distribution in the damage-zone of the Jorgillo Fault (JF), an ancient subvertical left-lateral strike-slip fault exposed in the Atacama Fault System in northern Chile. The JF is a ca. 20 km long NNW-striking strike-slip fault with sinistral displacement of ca. 4 km. The methodology consisted of drilling 5 mm vertically oriented plugs at several locations within the JF damage zone. Each specimen was scanned with an X-Ray µCT scanner, to assess the fracture mesh, with a voxel resolution of ca. 4.5 µm in the 3D reconstructed data. Tensor permeability modeling, using Lattice-Boltzmann Method, through the segmented microfracture mesh show GMkmin (geometric mean values) of 2.1x10-12 and 9.8x10-13 m2, and GMkmax of 6.4x10-12 and 2.1x10-12 m2. A high degree of anisotropy of the DZ permeability tensor both sides of the JF (eastern and western side, respectively) is observed, where the k values in the kmax plane are 2.4 and 1.9 times higher than the kmin direction at the time of fracture sealing. This style of anisotropy is consistent with the obtained for bedded sandstones supporting the idea that damage zones have an analogous effect - but vertically orientated - on bulk permeability (in low porosity rocks) as

  20. Risk Factors, Pathobiomechanics and Physical Examination of Rotator Cuff Tears

    PubMed Central

    Moulton, Samuel G.; Greenspoon, Joshua A.; Millett, Peter J.; Petri, Maximilian

    2016-01-01

    Background: It is important to appreciate the risk factors for the development of rotator cuff tears and specific physical examination maneuvers. Methods: A selective literature search was performed. Results: Numerous well-designed studies have demonstrated that common risk factors include age, occupation, and anatomic considerations such as the critical shoulder angle. Recently, research has also reported a genetic component as well. The rotator cuff axially compresses the humeral head in the glenohumeral joint and provides rotational motion and abduction. Forces are grouped into coronal and axial force couples. Rotator cuff tears are thought to occur when the force couples become imbalanced. Conclusion: Physical examination is essential to determining whether a patient has an anterosuperior or posterosuperior tear. Diagnostic accuracy increases when combining a series of examination maneuvers. PMID:27708731