46 CFR 160.076-21 - Component materials.
Code of Federal Regulations, 2010 CFR
2010-10-01
... by § 160.076-25(d)(2)(iii). (c) The average grab breaking strength and tear strength of the inflation....076-25(d)(2)(ii), must be at least 90% of the grab breaking strength and tear strength determined from... breaking strength or tear strength may be more than 20% below the results obtained in approval testing. (d...
Santago, Anthony C; Vidt, Meghan E; Li, Xiaotong; Tuohy, Christopher J; Poehling, Gary G; Freehill, Michael T; Saul, Katherine R
2017-12-01
Understanding upper limb strength requirements for daily tasks is imperative for early detection of strength loss that may progress to disability due to age or rotator cuff tear. We quantified shoulder strength requirements for 5 upper limb tasks performed by 3 groups: uninjured young adults and older adults, and older adults with a degenerative supraspinatus tear prior to repair. Musculoskeletal models were developed for each group representing age, sex, and tear-related strength losses. Percentage of available strength used was quantified for the subset of tasks requiring the largest amount of shoulder strength. Significant differences in strength requirements existed across tasks: upward reach 105° required the largest average strength; axilla wash required the largest peak strength. However, there were limited differences across participant groups. Older adults with and without a tear used a larger percentage of their shoulder elevation (p < .001, p < .001) and external rotation (p < .001, p = .017) strength than the young adults, respectively. Presence of a tear significantly increased percentage of internal rotation strength compared to young (p < .001) and uninjured older adults (p = .008). Marked differences in strength demand across tasks indicate the need for evaluating a diversity of functional tasks to effectively detect early strength loss, which may lead to disability.
Shin, Sang-Jin; Chung, Jaeyoon; Lee, Juyeob; Ko, Young-Won
2016-04-01
The recovery of muscle strength after arthroscopic rotator cuff repair based on the preoperative tear size has not yet been well described. The purpose of this study was to evaluate the recovery period of muscle strength by a serial assessment of isometric strength after arthroscopic rotator cuff repair based on the preoperative tear size. The hypothesis was that muscle strength in patients with small and medium tears would recover faster than that in those with large-to-massive tears. Cohort study; Level of evidence, 3. A total of 164 patients who underwent arthroscopic rotator cuff repair were included. Isometric strength in forward flexion (FF), internal rotation (IR), and external rotation (ER) was evaluated preoperatively and at 6, 12, 18, and 24 months after surgery. Preoperative magnetic resonance imaging scans were assessed to evaluate the quality of the rotator cuff muscle, including fatty infiltration, occupation ratio, and tangent sign. Patient satisfaction as well as visual analog scale (VAS) for pain, American Shoulder and Elbow Surgeons (ASES), and Constant scores were assessed at every follow-up. Muscle strength demonstrated the slowest recovery in pain relief and the restoration of shoulder function. To reach the strength of the uninjured contralateral shoulder in all 3 planes of motion, recovery took 6 months in patients with small tears and 18 months in patients with medium tears. Patients with large-to-massive tears showed continuous improvement in strength up to 18 months; however, they did not reach the strength of the contralateral shoulder at final follow-up. At final follow-up, mean strength in FF, IR, and ER was 113.0%, 118.0%, and 112.6% of the contralateral shoulder in patients with small tears, respectively; 105.0%, 112.1%, and 102.6% in patients with medium tears, respectively; and 87.6%, 89.5%, and 85.2% in patients with large-to-massive tears, respectively. Muscle strength in any direction did not significantly correlate with postoperative patient satisfaction (P = .374, .515, and .692 for FF, IR, and ER, respectively), whereas it highly correlated with preoperative quality of the muscle. The recovery of muscle strength after arthroscopic repair was poorly correlated with patient satisfaction. This study recommends that regardless of pain relief and improved shoulder function, patients with larger than medium tears should be encouraged to continue with rehabilitation for the maximal restoration of muscle strength beyond 1 year postoperatively. © 2016 The Author(s).
Artificially modified collagen fibril orientation affects leather tear strength.
Kelly, Susyn J; Wells, Hannah C; Sizeland, Katie H; Kirby, Nigel; Edmonds, Richard L; Ryan, Tim; Hawley, Adrian; Mudie, Stephen; Haverkamp, Richard G
2018-07-01
Ovine leather has around half the tear strength of bovine leather and is therefore not suitable for high-value applications such as shoes. Tear strength has been correlated with the natural collagen fibril alignment (orientation index, OI). It is hypothesized that it could be possible to artificially increase the OI of the collagen fibrils and that an artificial increase in OI could increase tear strength. Ovine skins, after pickling and bating, were strained biaxially during chrome tanning. The strain ranged from 2 to 15% of the initial sample length, either uniformly in both directions by 10% or with 3% in one direction and 15% in the other. Once tanned, the leather tear strengths were measured and the collagen fibril orientation was measured using synchrotron-based small-angle X-ray scattering. The OI increased as a result of strain during tanning from 0.48 to 0.79 (P = 0.001) measured edge-on and the thickness-normalized tear strength increased from 27 to 43 N mm -1 (P < 0.001) after leather was strained 10% in two orthogonal directions. This is evidence to support a causal relationship between high OI (measured edge-on), highly influenced by thickness, and tear strength. It also provides a method to produce stronger leather. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.
Functional outcomes of traumatic and non-traumatic rotator cuff tears after arthroscopic repair
Abechain, José Jorge Kitagaki; Godinho, Glaydson Gomes; Matsunaga, Fabio Teruo; Netto, Nicola Archetti; Daou, Julia Pozzetti; Tamaoki, Marcel Jun Sugawara
2017-01-01
AIM To compare the functional outcomes of traumatic and non-traumatic rotator cuff tears after arthroscopic repair. METHODS Eighty-seven patients with rotator cuff tears following arthroscopic treatment were divided into traumatic and non-traumatic tear groups. Postoperative muscle strength and outcomes using the modified University of California, Los Angeles score were evaluated. Sex, age, affected limb and dominant limb were correlated between groups. Muscle strength of the repaired and unaffected shoulders was compared. Rotator cuff injury size was measured. RESULTS Of the 87 patients who underwent rotator cuff repairs, 35 had traumatic tears and 52 had non-traumatic tears. In patients with non-traumatic tears, the average age was 59 years, 74.5% were female, 96.1% were right-hand dominant and 92.3% had their dominant shoulder affected. Patients with traumatic tears were 59.5 years old on average, 51.4% were female, 91.4% were right-hand dominant and 88.5% had their dominant shoulder affected. No difference existed in the mean modified University of California, Los Angeles score between patients with traumatic tears (33.7) compared with those with non-traumatic tears (32.8). No strength differences were observed between groups: The strength difference between the non-affected and affected sides was 1.21 kg in the non-traumatic group and 1.39 kg in the traumatic group (P = 0.576), while the strength ratio between the non-affected/affected sides was 0.805 in the non-traumatic group and 0.729 in the traumatic group (P = 0.224). CONCLUSION The functional results of traumatic rotator cuff repairs are similar to non-traumatic tears. Both outcomes are satisfactory. PMID:28875129
Evaluation of outgassing, tear strength, and detail reproduction in alginate substitute materials.
Baxter, R T; Lawson, N C; Cakir, D; Beck, P; Ramp, L C; Burgess, J O
2012-01-01
To compare three alginate substitute materials to an alginate impression material for cast surface porosity (outgassing), tear strength, and detail reproduction. Detail reproduction tests were performed following American National Standards Institute/American Dental Association (ANSI/ADA) Specification No. 19. To measure tear strength, 12 samples of each material were made using a split mold, placed in a water bath until testing, and loaded in tension until failure at a rate of 500 mm/min using a universal testing machine. For cast surface porosity testing, five impressions of a Teflon mold with each material were placed in a water bath (37.8°C) for the in-mouth setting time and poured with vacuum-mixed Silky Rock die stone at 5, 10, 30, and 60 minutes from the start of mixing. The gypsum samples were analyzed with a digital microscope for surface porosity indicative of hydrogen gas release by comparing the surface obtained at each interval with four casts representing no, little, some, and significant porosity. Data analysis was performed using parametric and Kruskal-Wallis analysis of variance (ANOVA), Tukey/Kramer post-hoc tests (α=0.05), and individual Mann-Whitney U tests (α=0.0167). All alginate substitute materials passed the detail reproduction test. Tear strength of the alginate substitute materials was significantly better than alginate and formed three statistically different groups: AlgiNot had the lowest tear strength, Algin-X Ultra had the highest tear strength, and Position Penta Quick had intermediate tear strength. Significant variation in outgassing existed between materials and pouring times (p<0.05). All alginate substitute materials exhibited the least outgassing and cast porosity 60 minutes after mixing. Detail reproduction and tear strength of alginate substitute materials were superior to traditional alginate. The outgassing effect was minimal for most materials tested. Alginate substitute materials are superior replacements for irreversible hydrocolloid.
NASA Technical Reports Server (NTRS)
Pleines, Wilhelm
1930-01-01
This report includes strength of riveted joints in duralumin, descriptions of test procedure and results of tests. Tabulated data includes: curshing strength by failure for various conditions, shearing strength of hole edge zone in direction of tearing, tearing strengths of plates weakened by rivet holes, and enlargement of holes at beginning of break.
46 CFR 160.076-11 - Incorporation by reference.
Code of Federal Regulations, 2011 CFR
2011-10-01
... following methods: (1) Method 5100, Strength and Elongation, Breaking of Woven Cloth; Grab Method, 160.076-25; (2) Method 5132, Strength of Cloth, Tearing; Falling-Pendulum Method, 160.076-25; (3) Method 5134, Strength of Cloth, Tearing; Tongue Method, 160.076-25. Underwriters Laboratories (UL) Underwriters...
Kim, Hyun-Jung; Lee, Jin-Hyuck; Ahn, Sung-Eun; Park, Min-Ji; Lee, Dae-Hee
2016-01-01
Theoretical compensation after anterior cruciate ligament (ACL) tear could cause quadriceps weakness and hamstring activation, preventing anterior tibial subluxation and affecting the expected hamstring-to-quadriceps ratio. Although quadriceps weakness often occurs after ACL tears, it remains unclear whether hamstring strength and hamstring-to-quadriceps ratio increase in ACL deficient knees. This meta-analysis compared the isokinetic muscle strength of quadriceps and hamstring muscles, and the hamstring-to-quadriceps ratio, of the injured and injured limbs of patients with ACL tears. This meta-analysis included all studies comparing isokinetic thigh muscle strengths and hamstring-to-quadriceps ratio in the injured and uninjured legs of patients with ACL tear, without or before surgery. Thirteen studies were included in the meta-analysis. Quadriceps and hamstring strengths were 22.3 N∙m (95% CI: 15.2 to 29.3 N∙m; P<0.001) and 7.4 N∙m (95% CI: 4.3 to 10.5 N∙m; P<0.001) lower, respectively, on the injured than on the uninjured side. The mean hamstring-to-quadriceps ratio was 4% greater in ACL deficient than in uninjured limbs (95% CI: 1.7% to 6.3%; P<0.001). Conclusively, Decreases were observed in both the quadriceps and hamstring muscles of patients with ACL tear, with the decrease in quadriceps strength being 3-fold greater. These uneven reductions slightly increase the hamstring-to-quadriceps ratio in ACL deficient knees.
Ahn, Sung-Eun; Park, Min-Ji; Lee, Dae-Hee
2016-01-01
Theoretical compensation after anterior cruciate ligament (ACL) tear could cause quadriceps weakness and hamstring activation, preventing anterior tibial subluxation and affecting the expected hamstring-to-quadriceps ratio. Although quadriceps weakness often occurs after ACL tears, it remains unclear whether hamstring strength and hamstring-to-quadriceps ratio increase in ACL deficient knees. This meta-analysis compared the isokinetic muscle strength of quadriceps and hamstring muscles, and the hamstring-to-quadriceps ratio, of the injured and injured limbs of patients with ACL tears. This meta-analysis included all studies comparing isokinetic thigh muscle strengths and hamstring-to-quadriceps ratio in the injured and uninjured legs of patients with ACL tear, without or before surgery. Thirteen studies were included in the meta-analysis. Quadriceps and hamstring strengths were 22.3 N∙m (95% CI: 15.2 to 29.3 N∙m; P<0.001) and 7.4 N∙m (95% CI: 4.3 to 10.5 N∙m; P<0.001) lower, respectively, on the injured than on the uninjured side. The mean hamstring-to-quadriceps ratio was 4% greater in ACL deficient than in uninjured limbs (95% CI: 1.7% to 6.3%; P<0.001). Conclusively, Decreases were observed in both the quadriceps and hamstring muscles of patients with ACL tear, with the decrease in quadriceps strength being 3-fold greater. These uneven reductions slightly increase the hamstring-to-quadriceps ratio in ACL deficient knees. PMID:26745808
29 CFR Appendix E to Subpart L of... - Test Methods for Protective Clothing
Code of Federal Regulations, 2012 CFR
2012-07-01
... strength of the specimen shall be the average of the five highest peak loads of resistance registered for 3... convenience. (2) Test method for determining the strength of cloth by tearing: Trapezoid Method. A. Test... directions shall be tested from each sample unit. (ii) The tearing strength of the sample unit shall be the...
29 CFR Appendix E to Subpart L of... - Test Methods for Protective Clothing
Code of Federal Regulations, 2014 CFR
2014-07-01
... strength of the specimen shall be the average of the five highest peak loads of resistance registered for 3... convenience. (2) Test method for determining the strength of cloth by tearing: Trapezoid Method. A. Test... directions shall be tested from each sample unit. (ii) The tearing strength of the sample unit shall be the...
Proprioceptive deficit in patients with complete tearing of the anterior cruciate ligament.
Godinho, Pedro; Nicoliche, Eduardo; Cossich, Victor; de Sousa, Eduardo Branco; Velasques, Bruna; Salles, José Inácio
2014-01-01
To investigate the existence of proprioceptive deficits between the injured limb and the uninjured (i.e. contralateral normal) limb, in individuals who suffered complete tearing of the anterior cruciate ligament (ACL), using a strength reproduction test. Sixteen patients with complete tearing of the ACL participated in the study. A voluntary maximum isometric strength test was performed, with reproduction of the muscle strength in the limb with complete tearing of the ACL and the healthy contralateral limb, with the knee flexed at 60°. The meta-intensity was used for the procedure of 20% of the voluntary maximum isometric strength. The proprioceptive performance was determined by means of absolute error, variable error and constant error values. Significant differences were found between the control group and ACL group for the variables of absolute error (p = 0.05) and constant error (p = 0.01). No difference was found in relation to variable error (p = 0.83). Our data corroborate the hypothesis that there is a proprioceptive deficit in subjects with complete tearing of the ACL in an injured limb, in comparison with the uninjured limb, during evaluation of the sense of strength. This deficit can be explained in terms of partial or total loss of the mechanoreceptors of the ACL.
46 CFR 160.176-4 - Incorporation by reference.
Code of Federal Regulations, 2014 CFR
2014-10-01
... and Elongation, Breaking of Woven Cloth; Grab Method, incorporation by reference approved for § 160.176-13. (ii) Method 5132, Strength of Cloth, Tearing; Falling-Pendulum Method, incorporation by reference approved for § 160.176-13. (iii) Method 5134, Strength of Cloth, Tearing; Tongue Method...
46 CFR 160.176-4 - Incorporation by reference.
Code of Federal Regulations, 2013 CFR
2013-10-01
... and Elongation, Breaking of Woven Cloth; Grab Method, incorporation by reference approved for § 160.176-13. (ii) Method 5132, Strength of Cloth, Tearing; Falling-Pendulum Method, incorporation by reference approved for § 160.176-13. (iii) Method 5134, Strength of Cloth, Tearing; Tongue Method...
46 CFR 160.077-5 - Incorporation by reference.
Code of Federal Regulations, 2013 CFR
2013-10-01
..., Breaking of Woven Cloth; Grab Method. (ii) Method 5132, Strength of Cloth, Tearing; Falling-Pendulum Method. (iii) Method 5134, Strength of Cloth, Tearing; Tongue Method. (iv) Method 5804.1, Weathering Resistance of Cloth; Accelerated Weathering Method. (v) Method 5762, Mildew Resistance of Textile Materials...
46 CFR 160.077-5 - Incorporation by reference.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Elongation, Breaking of Woven Cloth; Grab Method. (2) Method 5132, Strength of Cloth, Tearing; Falling-Pendulum Method. (3) Method 5134, Strength of Cloth, Tearing; Tongue Method. (4) Method 5804.1, Weathering Resistance of Cloth; Accelerated Weathering Method. (5) Method 5762, Mildew Resistance of Textile Materials...
46 CFR 160.077-5 - Incorporation by reference.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., Breaking of Woven Cloth; Grab Method. (ii) Method 5132, Strength of Cloth, Tearing; Falling-Pendulum Method. (iii) Method 5134, Strength of Cloth, Tearing; Tongue Method. (iv) Method 5804.1, Weathering Resistance of Cloth; Accelerated Weathering Method. (v) Method 5762, Mildew Resistance of Textile Materials...
46 CFR 160.077-5 - Incorporation by reference.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Elongation, Breaking of Woven Cloth; Grab Method. (2) Method 5132, Strength of Cloth, Tearing; Falling-Pendulum Method. (3) Method 5134, Strength of Cloth, Tearing; Tongue Method. (4) Method 5804.1, Weathering Resistance of Cloth; Accelerated Weathering Method. (5) Method 5762, Mildew Resistance of Textile Materials...
Uehara, Hiroki; Ono, Yasunori; Kakiage, Masaki; Sakamura, Takumi; Masunaga, Hiroyasu; Yukawa, Yasumasa; Higuchi, Yoshiaki; Kamiya, Hiroki; Yamanobe, Takeshi
2015-03-19
The property development of the ethylene-tetrafluoroethylene copolymer (ETFE) membrane induced by simultaneous biaxial drawing was investigated. Commonly, tensile strength can be increased by drawing; conversely, tear resistance decreases. In this study, the balance between tensile strength and tear resistance for the resultant ETFE membrane was optimized achieved by a combination of lamination of low molecular weight (LMW) and high molecular weight (HMW) layers and subsequent biaxial drawing. The structural factor determining tear resistance of these biaxially drawn membranes was determined based on in situ small-angle X-ray scattering (SAXS) measurement during tensile deformation simulating tearing tests. Lozenge shaped scattering, which indicated inclined lamellae, was observed during such tensile deformation of the resultant membranes. Remarkably, this inclined lamellar structure was observed for the pure LMW membrane; however, it also appeared at the interface between LMW and HMW layers within biaxially drawn membranes. For the membrane exhibiting the highest tearing strength, the fraction of such inclined lamella increased up to the critical strain corresponding to the actual sample breaking. These results confirm that the inclined lamellar structure absorbed strain during membrane tearing.
46 CFR 160.176-4 - Incorporation by reference.
Code of Federal Regulations, 2012 CFR
2012-10-01
... and Elongation, Breaking of Woven Cloth; Grab Method—160.176-13 (2) Method 5132, Strength of Cloth, Tearing; Falling-Pendulum Method—160.176-13 (3) Method 5134, Strength of Cloth, Tearing; Tongue Method—160.176-13 (4) Method 5804.1, Weathering Resistance of Cloth; Accelerated Weathering Method—160.176-8 (5...
Nonsurgical Treatment of Acetabular Labral Tears.
Theige, Melissa; David, Shannon
2018-05-04
Clinical Scenario: Surgical treatment of acetabular labral tears has been explored in multiple studies, while there is a lack of research on the effectiveness of conservative methods. Focused Clinical Question: To what extent can nonsurgical treatment produce symptomatic or functional improvements in athletes with an acetabular labral tear? Summary of Search, Best Evidence Appraised, and Key Findings: The literature was searched for studies of patients with confirmed acetabular labral tears who participated in any level of sport. Four studies were located, all of which were included. Clinical Bottom Line: The research discussed in this review agreed that conservative management of acetabular labral tears produced measurable improvements in pain and function among the athletes studied, including their ability to participate in sport activities. Based on these findings, it appears that conservative management is effective at rehabilitating athletes with acetabular labral tears. However, this method should not be applied to every athlete based on the low strength of current research. Treatment plans should be decided upon on a case-by-case basis. Strength of Recommendation: The studies located were of low quality. The highest Oxford Center for Evidence-Based Medicine Level of Evidence achieved was 4. Higher level studies must be conducted before the conclusions of this research can be applied clinically with assertion. Strength of recommendation is level 3.
Are pain location and physical examinations useful in locating a tear site of the rotator cuff?
Itoi, Eiji; Minagawa, Hiroshi; Yamamoto, Nobuyuki; Seki, Nobutoshi; Abe, Hidekazu
2006-02-01
Pain is the most common symptom of patients with rotator cuff tendinopathy, but little is known about the relationship between the site of pain and the site of cuff pathologic lesions. Also, accuracies of physical examinations used to locate a tear by assessing the muscle strength seem to be affected by the threshold for muscle weakness, but no studies have been reported regarding the efficacies of physical examinations in reference to their threshold. Pain location is useful in locating a tear site. Efficacies of physical examinations to evaluate the function of the cuff muscles depend on the threshold for muscle weakness. Case series; Level of evidence, 4. The authors retrospectively reviewed the clinical charts of 160 shoulders of 149 patients (mean age, 53 years) with either rotator cuff tears (140 shoulders) or cuff tendinitis (20 shoulders). The location of pain was recorded on a standardized form with 6 different areas. The diagnostic accuracies of the following tests were assessed with various thresholds for muscle weakness: supraspinatus test, the external rotation strength test, and the lift-off test. Lateral and anterior portions of the shoulder were the most common sites of pain regardless of existence of tear or tear location. The supraspinatus test was most accurate when it was assessed to have positive results with the muscle strength less than manual muscle testing grade 5, whereas the lift-off test was most accurate with a threshold less than grade 3. The external rotation strength test was most accurate with a threshold of less than grade 4+. The authors conclude that pain location is not useful in locating the site of a tear, whereas the physical examinations aiming to locate the tear site are clinically useful when assessed to have positive results with appropriate threshold for muscle weakness.
Asymptomatic rotator cuff tears: Patient demographics and baseline shoulder function
Keener, Jay D.; Steger-May, Karen; Stobbs, Georgia; Yamaguchi, Ken
2010-01-01
Background The purpose of this study is to characterize the demographic features and physical function of subjects with asymptomatic rotator cuff tears and to compare their shoulder function to controls with an intact rotator cuff. Materials and Methods 196 subjects with an asymptomatic rotator cuff tear and 54 subjects with an intact rotator cuff presenting with a painful rotator cuff tear in the contralateral shoulder were enrolled. Various demographic features, shoulder function (ASES score and SST score), range of motion and strength were compared. Results The demographic features of the study and control groups were similar. Hand dominance was associated with the presence of shoulder pain (p < .05). Subjects with an intact rotator cuff had greater but clinically insignificant ASES (p < .05) and SST scores (p < .05) than those with an asymptomatic tear. No differences in functional scores, range of motion or strength were seen between partial (n=61) and full-thickness tears (n=135). Of the full-thickness tears, 36 (27%) were classified as small, 85 (63%) as medium and 14 (10%) as large tears. No differences were seen in functional scores between full-thickness tears of various sizes. Conclusions When asymptomatic, a rotator cuff tear is associated with a clinically insignificant loss of shoulder function compared to those with an intact rotator cuff. Therefore, a clinically detectable decline in shoulder function may indicate an “at-risk” asymptomatic tear. The presence of pain is important in cuff deficient shoulders for creating a measurable loss of shoulder function. Hand dominance appears to be an important risk factor for pain. PMID:21030274
Guo, Nan; Jiao, Ting
2011-08-01
To study the effect of surface organic modified nano-silicon-oxide (SiO(x)) on mechanical properties of A-2186 silicone elastomers. Surface organic modified nano-silicon-oxide (SiO(x)) was added into A-2186 silicone elastomers by weight percentage of 2%, 4% and 6%. The one without addition served as a control. Standard specimens were made according to American Society for Testing Materials (ASTM). Their tensile strength, elongation at break, tear strength, and Shore A hardness were measured. The results were analyzed statistically by SPSS 10.0 software package. The tensile strength in the experimental groups was significantly lower than the control group (P<0.001).The elongation in the experimental groups was lower than the control group, but there was no significant difference between the 2wt% group and the control group (P=0.068). The tear strength in both the 2wt= group and 4wt= group were higher than the control group, and the difference was statistically significant; in addition, the tear strength in 2wt= group was higher than 4wt= group, which also showed statistical significance (P<0.001). With the increase of the added amount of surface modified nano-SiO(x), Shore A hardness increased and there was significant difference among them (P<0.001). Adding surface modified nano-SiO(x) has an effect on mechanical properties of A-2186 silicone elastomer, when 2wt= and 4wt= are added, tear strength of A-2186 improves significantly, with an increase of Shore A hardness and an decrease of tensile strength.
Investigation of Tear Biomarkers as an Indicator of Human Health
NASA Technical Reports Server (NTRS)
Morton, Stephen; Tucker, Bethany; Crucian, Brian; Steinberg, Susan; Hagan, Suzanne
2017-01-01
Scientific literature suggests that tear biomarkers can be used as a guide towards clinical diagnosis of human health (Hagan et al., 2016). This study will investigate whether tear biomarkers represents a research and clinical opportunity to assess human health prior to, during, and after exposure to the spaceflight environment. The focus of this study is to compare biomarkers previously identified as potentially relevant to both ocular and brain health against unique physiological outcomes of exposure to the space flight environment. Study subjects suffering from terrestrial conditions thought to be similar to Spaceflight Associated Neuro-ocular Syndrome (SANS: formerly VIIP), e.g. patients with idiopathic intracranial hypertension (IIH) and optic neuritis may be relevant to conditions associated with spaceflight. This study will review methodologies, tear biomarkers related to state of ocular and brain health, the strengths and weakness of using tear fluid biomarkers versus other body fluid samples, and will survey current tear fluid biomarker knowledge in research and clinical practice. A strength of using tear biomarkers is that sampling is non-invasive and used as a guide in understanding pathologies, including ocular and systemic inflammatory conditions (Cocho et al., 2016)., Salvisberg et al., 2014). Moreover, tear biomarkers may reflect diseases affecting the central nervous system (CNS) (Salvisberg et al., 2014). For example, in multiple sclerosis (MS), the concordance rate between tear biomarkers versus cerebrospinal fluid (CSF) is approximately 83%, indicating that, in the majority of cases, tears are at least as effective as CSF in potentially identifying novel MS biomarkers (Devos et al., 2001).
Wang, Yue; Gregory, Cherry; Minor, Mark A
2018-06-01
Molded silicone rubbers are common in manufacturing of soft robotic parts, but they are often prone to tears, punctures, and tensile failures when strained. In this article, we present a fabric compositing method for improving the mechanical properties of soft robotic parts by creating a fabric/rubber composite that increases the strength and durability of the molded rubber. Comprehensive ASTM material tests evaluating the strength, tear resistance, and puncture resistance are conducted on multiple composites embedded with different fabrics, including polyester, nylon, silk, cotton, rayon, and several blended fabrics. Results show that strong fabrics increase the strength and durability of the composite, valuable in pneumatic soft robotic applications, while elastic fabrics maintain elasticity and enhance tear strength, suitable for robotic skins or soft strain sensors. Two case studies then validate the proposed benefits of the fabric compositing for soft robotic pressure vessel applications and soft strain sensor applications. Evaluations of the fabric/rubber composite samples and devices indicate that such methods are effective for improving mechanical properties of soft robotic parts, resulting in parts that can have customized stiffness, strength, and vastly improved durability.
Neumann, Julie A; Zgonis, Miltiadis H; Rickert, Kathleen D; Bradley, Kendall E; Kremen, Thomas J; Boggess, Blake R; Toth, Alison P
2017-05-01
Management of massive rotator cuff tears in shoulders without glenohumeral arthritis remains problematic for surgeons. Repairs of massive rotator cuff tears have failure rates of 20% to 94% at 1 to 2 years postoperatively as demonstrated with arthrography, ultrasound, and magnetic resonance imaging. Additionally, inconsistent outcomes have been reported with debridement alone of massive rotator cuff tears, and limitations have been seen with other current methods of operative intervention, including arthroplasty and tendon transfers. The use of interposition porcine acellular dermal matrix xenograft in patients with massive rotator cuff tears will result in improved subjective outcomes, postoperative pain, function, range of motion, and strength. Case series; Level of evidence, 4. Sixty patients (61 shoulders) were prospectively observed for a mean of 50.3 months (range, 24-63 months) after repair of massive rotator cuff tears with porcine acellular dermal matrix xenograft as an interposition graft. Subjective outcome data were obtained with visual analog scale for pain score (0-10, 0 = no pain) and Modified American Shoulder and Elbow Surgeons (MASES) score. Active range of motion in flexion, external rotation, and internal rotation were recorded. Strength in the supraspinatus and infraspinatus muscles was assessed manually on a 10-point scale and by handheld dynamometer. Ultrasound was used to assess the integrity of the repair during latest follow-up. Mean visual analog scale pain score decreased from 4.0 preoperatively to 1.0 postoperatively ( P < .001). Mean active forward flexion improved from 140.7° to 160.4° ( P < .001), external rotation at 0° of abduction from 55.6° to 70.1° ( P = .001), and internal rotation at 90° of abduction from 52.0° to 76.2° ( P < .001). Supraspinatus manual strength increased from 7.7 to 8.8 ( P < .001) and infraspinatus manual strength from 7.7 to 9.3 ( P < .001). Mean dynamometric strength in forward flexion was 77.7 N in nonoperative shoulders (shoulder that did not undergo surgery) and 67.8 N ( P < .001) in operative shoulders (shoulder that underwent rotator cuff repair with interposition porcine dermal matrix xenograft). Mean dynamometric strength in external rotation was 54.5 N in nonoperative shoulders and 50.1 N in operative shoulders ( P = .04). Average postoperative MASES score was 87.8. Musculoskeletal ultrasound showed that 91.8% (56 of 61) of repairs were fully intact; 3.3% (2 of 61), partially intact; and 4.9% (3 of 61), not intact. Patients who underwent repair of massive rotator cuff tears with interposition porcine acellular dermal matrix graft have good subjective function as assessed by the MASES score. Patients have significant improvement in pain, range of motion, and manual muscle strength. Postoperative ultrasound demonstrated that the repair was completely intact in 91.8% of patients, a vast improvement compared with results previously reported for primary repairs of massive rotator cuff tears.
Polyimide Film of Increased Tear Strength
NASA Technical Reports Server (NTRS)
St. Clair, A. K.; Hinkley, J. A.; Ezzell, S. A.
1986-01-01
High-temperature linear aromatic polyimide with improved resistance to tearing made by new process that incorporates elastomer into polyimide. Linear aromatic condensation polyimides are materials of prime choice for use as films and coatings on advanced spacecraft and aircraft where durability at temperatures in range of 200 to 300 degree C required. Elastomer-containing polyimide film with improved toughness proves useful for applications where resistance to tearing and long-term thermal stability necessary. Desired resistance to tearing achieved by careful control of amount and chemical composition of added elastomer.
The effect of mimosa and syntan mixture on the quality of tanned red snapper leather
NASA Astrophysics Data System (ADS)
Pratama, M.; Sahubawa, L.; Pertiwiningrum, A.; Rahmadian, Y.; Puspita, I. D.
2018-03-01
This study aimed to determine the effect of syntan and mimosa combination on the quality of tanned red snapper leather. The study was designed using complete randomized design (CRD) and the advanced test of Least Significant Difference (LSD) with three replications and three treatments of combined syntan and mimosa, namely: p1 (4 % syntan, 5 % mimosa), p2 (8 % syntan, 5 %mimosa), p3 (12 % syntan, 5 % mimosa). Data were analyzed using SPSS 18. The measured parameters were tensile strength (N·cm-2), elongation (%), tear strength (N·cm-1), enervation (mm), wrinkle temperature (°C), fat/oil content (%) and water content (%). The results indicate that the combined syntan and mimosa tanners gave no significant effect on the physical parameters (tensile strength, elongation, tear strength, enervation and wrinkle temperature) and chemical parameters (moisture and fat/oil). All treatments (p1, p2 and p3) met the Indonesian National Standard (SNI) 06-4586-1998 for chrome tanned freshwater snake leather for the parameters of tensile strength, tear strength, enervation, wrinkle temperature and moisture. The parameter of elongation and fat/oil content did not meet with the SNI 06-4586-1998. Among the three combinations of a tanner, syntan 4 % and mimosa 5 % treatment gave the best leather quality.
Development and production of a flame retardant, general purpose, pressure sensitive adhesive tape
NASA Technical Reports Server (NTRS)
Monaghan, P. B.; Doggett, R. H.
1977-01-01
The specification results for the finished tape properties were as follows: (1) adhesive strength (180 deg peel) on aluminum from 107 to 143 grams per centimeter (0.6 to 0.8 pounds per inch); (2) adhesive strength (180 deg peel) on stainless steel from 71 to 107 grams per centimeter (0.4 to 0.6 pounds per inch); (3) unwind resistance of 536 to 714 grams per centimeter (3 to 4 pounds per inch); (4) tensile strength minimum of 7143 grams per centimeter (40 pounds per inch); (5) elongation from 5 to 10% at break; (6) tear strength, Elmendorf from 200 to 350 grams (0.44 to 0.77 pounds); and (7) tear strength, tongue from 363 to 408 grams (0.8 to 0.9) pounds).
Pullout failure strength of the posterior horn of the medial meniscus with root ligament tear.
Kim, Young-Mo; Joo, Yong-Bum
2013-07-01
To evaluate the reparability of the posterior horn of the medial meniscus with root ligament tear by measuring the actual pullout failure strength of a simple vertical suture of an arthroscopic subtotal meniscectomized posterior horn of the medial meniscus. From November 2009 to May 2010, nine posterior horns of the medial meniscus specimens were collected from arthroscopic subtotal meniscectomy performed as a treatment for root ligament rupture of the posterior horn of the medial meniscus. Simple vertical sutures were performed on the specimens, and pullout failure load was tested with a biaxial servohydraulic testing machine (Model 8874; Instron Corp., Norwood, MA, USA). The degree of degeneration, extrusion, and medial displacement of the medial meniscus were evaluated with magnetic resonance imaging (MRI). The Kellgren-Lawrence classification was used in standing plain radiography, and mechanical alignment was measured using orthoroentgenography. Tear morphology was classified into ligament proper type or meniscoligamentous junctional type according to the site of the torn root ligament of the posterior horn of the medial meniscus during arthroscopy. The mean pullout failure strength of the posterior horn of the medial meniscus was 71.6 ± 23.2 N (range, 41.4-107.7 N). The degree of degeneration of the posterior horn of the medial meniscus on MRI showed statistically significant correlation with pullout failure strength and Kellgren-Lawrence classification. Pullout failure strength showed correlation with mechanical alignment and Kellgren-Lawrence classification (P < 0.05). The measurement of pullout failure strength of the posterior horn of the medial meniscus with root ligament tear showed a degree of repairability. The degree of degeneration of the posterior horn of the medial meniscus on MRI showed a significant correlation with the pullout failure strength. The pullout failure strength was also not only correlated with the degree of degeneration of the posterior horn of the medial meniscus, but also with mechanical alignment and Kellgren-Lawrence classification, which represent bony degenerative change.
Macías-Hernández, Salvador Israel; Pérez-Ramírez, Luis Enrique
2015-01-01
Rotator cuff tears are the leading cause of pain and functional disability of the shoulder. Conservative treatment is an essential part of their management. Despite the limited evidence, rehabilitation is the mainstay of the treatment for rotator cuff tears associated to impingement syndrome. There are current reports on the utility of strengthening with resistance, particularly by eccentric exercise. This report aims to present an overview of the efficacy of eccentric exercises in tendinopathies and current evidence of its benefit in rotator cuff tears. We describe the information available in tendinopathy and analyzed four studies published on eccentric strengthening for rotator cuff tears. There is theoretical evidence about its usefulness in this pathology, but only a controlled clinical trial has been published with data on improvement in strength but not in pain or functionality. More studies are needed with better methodological designs in order to generate evidence of their utility and recommendation. Copyright © 2015. Published by Masson Doyma México S.A.
Ebert, Jay R; Retheesh, Theertha; Mutreja, Rinky; Janes, Gregory C
2016-10-01
Hip abductor tendon (HAT) tearing is commonly implicated in greater trochanteric pain syndrome (GTPS), though limited information exists on the disability associated with this condition and specific presentation of these patients. To describe the clinical, functional and biomechanical presentation of patients with symptomatic HAT tears. Secondary purposes were to investigate the association between these clinical and functional measures, and to compare the pain and disability reported by HAT tear patients to those with end-stage hip osteoarthritis (OA). Prospective case series. One hundred forty-nine consecutive patients with symptomatic HAT tears were evaluated using the Harris (HHS) and Oxford (OHS) Hip Scores, SF-12, an additional series of 10 questions more pertinent to those with lateral hip pain, active hip range of motion (ROM), maximal isometric hip abduction strength, six-minute walk capacity and 30-second single limb stance (SLS) test. The presence of a Trendelenburg sign and pelvis-on-femur (POF) angle were determined via 2D video analysis. An age matched comparative sample of patients with end-stage hip OA was recruited for comparison of all patient-reported outcome scores. Independent t-tests investigated group and limb differences, while analysis of variance evaluated pain changes during the functional tests. Pearson's correlation coefficients investigated the correlation between clinical measures in the HAT tear group. No differences existed in patient demographics and patient-reported outcome scores between HAT tear and hip OA cohorts, apart from significantly worse SF-12 mental subscale scores (p = 0.032) in the HAT tear group. Patients with HAT tears demonstrated significantly lower (p < 0.05) hip abduction strength and active ROM in all planes of motion on their affected limb. Pain significantly increased throughout the 30-second SLS test for the HAT tear group, with 57% of HAT tear patients demonstrating a positive Trendelenburg sign. POF angle during the test was not significantly associated with pain. Patients with symptomatic HAT tears demonstrate poor function, and report pain and disability similar to or worse than those with end-stage hip OA. This information better defines and differentiates the presentation of these patients. Level 3 case-controlled study, with matched comparison.
Dandeniyage, Loshini S; Gunatillake, Pathiraja A; Adhikari, Raju; Bown, Mark; Shanks, Robert; Adhikari, Benu
2017-08-31
Mixed macrodiol based siloxane poly(urethane-urea)s (SiPUU) having number average molecular weights in the range 87-129 kDa/mol were synthesized to give elastomers with high tensile and tear strengths required to fabricate artificial heart valves. Polar functional groups were introduced into the soft segment to improve the poor segmental compatibility of siloxane polyurethanes. This was achieved by linking α,ω-bis(6-hydroxyethoxypropyl) poly(dimethylsiloxane) (PDMS) or poly(hexamethylene oxide) (PHMO) macrodiols with either 4,4'-methylenediphenyl diisocyanate (MDI), hexamethylene diisocyanate (HDI) or isophorone diisocyanate (IPDI) prior to polyurethane synthesis. The hard segment was composed of MDI, and a 1:1 mixture of 1,3-bis(4-hydroxybutyl)-1,1,3,3-tetramethyldisiloxane and 1,2-ethylene diamine. We report the effect of urethane linkers in soft segments on properties of the SiPUU. PHMO linked with either MDI or IPDI produced SiPUU with the highest tensile and tear strengths. Linking PDMS hardly affected the tensile strength; however, the tear strength was improved. The stress-strain curves showed no plastic deformation region typically observed for conventional polyurethanes indicating good creep resistance. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2017. © 2017 Wiley Periodicals, Inc.
7 CFR 29.3061 - Strength (tensile).
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 2 2010-01-01 2010-01-01 false Strength (tensile). 29.3061 Section 29.3061... Type 93) § 29.3061 Strength (tensile). The stress a tobacco leaf can bear without tearing. Tensile strength is not an important element of quality in Burley tobacco. [24 FR 8771, Oct. 29, 1959. Redesignated...
7 CFR 29.3061 - Strength (tensile).
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 2 2011-01-01 2011-01-01 false Strength (tensile). 29.3061 Section 29.3061... Type 93) § 29.3061 Strength (tensile). The stress a tobacco leaf can bear without tearing. Tensile strength is not an important element of quality in Burley tobacco. [24 FR 8771, Oct. 29, 1959. Redesignated...
THE EFFECTS OF $gamma$-IRRADIATION AND ROLLING ON THE TEARING PROPERTIES OF POLYETHYLENE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsunekawa, Y.; Awatani, J.; Kojima, K.
1961-01-01
Polyethylene samples of 2 mm thickness were gamma irradiated in water. The total dosage for the samples irradiated after the rolling treatraent was 1.5 x lO/sup 5/ r/hr, while the dosage for the saraples irradiated before the rolling was 1.2 x lO/sup 5/ r/hr. The tensile strength of the irradiated and rolled saraple increased with increasing dosage. A comparison of tearing strengths between the rolled samples and the rolled and irradiated samples was raade. (OID)
76 FR 60405 - Inflatable Personal Flotation Devices
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-29
... criteria for the grab breaking strength, tear strength, seam strength, and permeability tests for inflation... Determining Gas Permeability Characteristics of Plastic Film and Sheeting), because those standards, or... Government and Indian tribes, or on the distribution of power and responsibilities between the Federal...
76 FR 17561 - Inflatable Personal Flotation Devices
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-30
... the grab breaking strength, tear strength, seam strength, and permeability tests for inflation chamber... Coated Fabrics), and ASTM D 1434-82 (Standard Test Method for Determining Gas Permeability... Government and Indian tribes, or on the distribution of power and responsibilities between the Federal...
EXPERIMENTAL MODELLING OF AORTIC ANEURYSMS
Doyle, Barry J; Corbett, Timothy J; Cloonan, Aidan J; O’Donnell, Michael R; Walsh, Michael T; Vorp, David A; McGloughlin, Timothy M
2009-01-01
A range of silicone rubbers were created based on existing commercially available materials. These silicones were designed to be visually different from one another and have distinct material properties, in particular, ultimate tensile strengths and tear strengths. In total, eleven silicone rubbers were manufactured, with the materials designed to have a range of increasing tensile strengths from approximately 2-4MPa, and increasing tear strengths from approximately 0.45-0.7N/mm. The variations in silicones were detected using a standard colour analysis technique. Calibration curves were then created relating colour intensity to individual material properties. All eleven materials were characterised and a 1st order Ogden strain energy function applied. Material coefficients were determined and examined for effectiveness. Six idealised abdominal aortic aneurysm models were also created using the two base materials of the study, with a further model created using a new mixing technique to create a rubber model with randomly assigned material properties. These models were then examined using videoextensometry and compared to numerical results. Colour analysis revealed a statistically significant linear relationship (p<0.0009) with both tensile strength and tear strength, allowing material strength to be determined using a non-destructive experimental technique. The effectiveness of this technique was assessed by comparing predicted material properties to experimentally measured methods, with good agreement in the results. Videoextensometry and numerical modelling revealed minor percentage differences, with all results achieving significance (p<0.0009). This study has successfully designed and developed a range of silicone rubbers that have unique colour intensities and material strengths. Strengths can be readily determined using a non-destructive analysis technique with proven effectiveness. These silicones may further aid towards an improved understanding of the biomechanical behaviour of aneurysms using experimental techniques. PMID:19595622
The biodurability of covering materials for metallic stents in a bile flow phantom.
Bang, Byoung Wook; Jeong, Seok; Lee, Don Haeng; Lee, Jung Il; Lee, Se Chul; Kang, Sung-Gwon
2012-04-01
Covered biliary metal stents have been introduced for the purpose of overcoming tumor ingrowth and treatment of benign biliary stricture. The aim of this study was to evaluate the biodurability of three commercially available biliary metal stent covering materials [e-PTFE (expanded polytetrafluoroethylene), silicone, and polyurethane] in a bile flow phantom. By operation of a peristaltic pump, human bile was circulated continuously in an experimental perfusion system containing covered metal stents. Each stent was removed, respectively, 1, 2, 4, and 6 months after bile exposure. We performed a gross inspection of the covered stents. The covering membrane was detached from the stent and observed by scanning electron microscopy (SEM). Finally, we measured tensile and tear strength of the membranes. Bile-staining of the membrane showed gradual progression after bile exposure; however, progress was the fastest in e-PTFE. SEM examination showed that the polyurethane surface was smooth, and the silicone surface was relatively smooth. However, e-PTFE had a rough and uneven surface. After bile exposure, there were no significant changes in polyurethane and silicone; however, biofilms and microcracks were observed in e-PTFE. In contrast to a gradual decrease of tensile/tear strength of polyurethane and silicone, those of e-PTFE showed a rapid reduction despite of the strongest baseline tensile and tear strength. e-PTFE tended to form biofilms more frequently than polyurethane and silicone during bile exposure. e-PTFE seemed to be less durable than silicone and polyurethane, however, as clinically applicable material because of strong absolute tensile/tear strengths.
Nakamura, Yoshihiro; Yokoya, Shin; Harada, Yohei; Shiraishi, Katsunori; Adachi, Nobuo; Ochi, Mitsuo
2017-07-01
The purpose of this study was to evaluate the relationship of fatty infiltration in rotator cuff muscles and shoulder strength in rotator cuff tears and these changes during nonsurgical treatment. Fifty-three shoulders from 47 patients (mean age: 69.9 years) diagnosed with rotator cuff tears by magnetic resonance imaging (MRI) were treated nonsurgically. The degrees of fatty infiltration in supraspinatus (SSP) and infraspinatus (ISP) muscles were graded by the modified Goutallier classification (grade 0-1, grade 2-3, or grade 4). The isometric strength of the abductors (Abd) and external rotators (ER) were examined with a hand dynamometer. We analyzed the correlation of the modified Goutallier classification in SSP and ISP muscles with the strength of Abd and ER at initial visit. In addition, MRI and strength tests were repeated after 24 ± 6 months, and changes in fatty infiltration and strength were examined. Fatty infiltration of SSP and ISP muscles had a negative correlation with the strengths of Abd and ER at initial visit, respectively. Six of 45 shoulders (SSP grade: 0-3) and 7 of 43 shoulders (ISP grade: 0-3) had progression of fatty infiltration. Predictive factor of a progression of fatty infiltration during follow-up was decreased initial strength of Abd. There was no significant change in the strength of Abd, and the strength of ER showed significant improvement between the initial and post-treatment measurements. Even in the subgroup that had progression of fatty infiltration at follow-up, the strength of Abd and ER did not decrease significantly. Although fatty infiltration of the rotator cuff muscles exhibited a negative correlation with muscle strength, fatty infiltration and muscle weakness did not progress at the same rate. Copyright © 2017 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
Retheesh, Theertha; Mutreja, Rinky; Janes, Gregory C.
2016-01-01
Background Hip abductor tendon (HAT) tearing is commonly implicated in greater trochanteric pain syndrome (GTPS), though limited information exists on the disability associated with this condition and specific presentation of these patients. Purpose To describe the clinical, functional and biomechanical presentation of patients with symptomatic HAT tears. Secondary purposes were to investigate the association between these clinical and functional measures, and to compare the pain and disability reported by HAT tear patients to those with end-stage hip osteoarthritis (OA). Study Design Prospective case series. Methods One hundred forty-nine consecutive patients with symptomatic HAT tears were evaluated using the Harris (HHS) and Oxford (OHS) Hip Scores, SF-12, an additional series of 10 questions more pertinent to those with lateral hip pain, active hip range of motion (ROM), maximal isometric hip abduction strength, six-minute walk capacity and 30-second single limb stance (SLS) test. The presence of a Trendelenburg sign and pelvis-on-femur (POF) angle were determined via 2D video analysis. An age matched comparative sample of patients with end-stage hip OA was recruited for comparison of all patient-reported outcome scores. Independent t-tests investigated group and limb differences, while analysis of variance evaluated pain changes during the functional tests. Pearson's correlation coefficients investigated the correlation between clinical measures in the HAT tear group. Results No differences existed in patient demographics and patient-reported outcome scores between HAT tear and hip OA cohorts, apart from significantly worse SF-12 mental subscale scores (p = 0.032) in the HAT tear group. Patients with HAT tears demonstrated significantly lower (p < 0.05) hip abduction strength and active ROM in all planes of motion on their affected limb. Pain significantly increased throughout the 30-second SLS test for the HAT tear group, with 57% of HAT tear patients demonstrating a positive Trendelenburg sign. POF angle during the test was not significantly associated with pain. Conclusion Patients with symptomatic HAT tears demonstrate poor function, and report pain and disability similar to or worse than those with end-stage hip OA. This information better defines and differentiates the presentation of these patients. Level of Evidence Level 3 case-controlled study, with matched comparison PMID:27757285
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 2 2010-01-01 2010-01-01 false Strength. 29.2303 Section 29.2303 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Strength. The stress a tobacco leaf can bear without tearing. (See chart, § 29.2351.) [37 FR 13521, July 11...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 2 2011-01-01 2011-01-01 false Strength. 29.2303 Section 29.2303 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Strength. The stress a tobacco leaf can bear without tearing. (See chart, § 29.2351.) [37 FR 13521, July 11...
NASA Astrophysics Data System (ADS)
Mohamed, R.; Nurazzi, N. Mohd; Huzaifah, M.
2017-07-01
This study was conducted to investigate the possibility of utilizing sludge palm oil (SPO) as processing oil, with various amount of carbon black as its reinforcing filler, and its effects on the curing characteristics and mechanical properties of natural rubber/styrene butadiene rubber (NR/SBR) compound. Rubber compound with fixed 15 pphr of SPO loading, and different carbon black loading from 20 to 50 pphr, was prepared using two roll mills. The cure characteristics and mechanical tests that have been conducted are the scorch and cure time analysis, tensile strength and tear strength. Scorch time (ts5) and cure time (t90) of the compound increases with the increasing carbon black loading. The mechanical properties of NR/SBR compound viz. the tensile strength, modulus at 300% strain and tear strength were also improved by the increasing carbon black loading.
Afra, Elyas; Yousefi, Hossein; Hadilam, Mohamad Mahdi; Nishino, Takashi
2013-09-12
Cellulose fibers were fibrillated using mechanical beating (shearing refiner) and ultra-fine friction grinder, respectively. The fibrillated fibers were then used to make paper. Mechanical beating process created a partial skin fibrillation, while grinding turned fiber from micro to nanoscale through nanofibrillation mechanism. The partially fibrillated and nano fibrillated fibers had significant effects on paper density, tear strength, tensile strength and water drainage time. The effect of nanofibrillation on paper properties was quantitatively higher than that of mechanical beating. Paper sheets from nanofibrillated cellulose have a higher density, higher tensile strength and lower tear strength compared to those subjected to mechanical beating. Mechanical beating and nanofibrillation were both found to be promising fiber structural modifications. Long water drainage time was an important drawback of both fibrillation methods. Copyright © 2013 Elsevier Ltd. All rights reserved.
Effects of cationic xylan from annual plants on the mechanical properties of paper.
Deutschle, Alexander L; Römhild, Katrin; Meister, Frank; Janzon, Ron; Riegert, Christiane; Saake, Bodo
2014-02-15
Xylan from oat spelt and wheat was used as an additive to enhance the dry strength of paper. The absorption of xylan by the cellulose fibers was increased by cationization to different degrees of substitution. Paper hand sheets with different doses of xylan and industrial cationic starch were produced, and the mechanical properties were determined. Absorption measurements of cationic oat spelt xylan on pulp fibers explained the differing influences of low and high cationized xylan addition on paper strength. The addition of cationic oat spelt xylan with a degree of substitution of 0.1 at a 4% dose provided the largest improvement in the tensile-index (67%), burst-index (105%) and tear-index (77%). Compared to cationic starch, cationic oat spelt xylan additives led to similar paper strength values, excepting the tear strength. The structural differences and protein impurities made the wheat xylan unsuitable as a strength additive for paper pulp. Copyright © 2013 Elsevier Ltd. All rights reserved.
Time-dependent Fracture Behaviour of Polyampholyte Hydrogels
NASA Astrophysics Data System (ADS)
Sun, Tao Lin; Luo, Feng; Nakajima, Tasuku; Kurokawa, Takayuki; Gong, Jian Ping
Recently, we report that polyampholytes, polymers bearing randomly dispersed cationic and anionic repeat groups, form tough and self-healing hydrogels with excellent multiple mechanical functions. The randomness makes ionic bonds with a wide distribution of strength, via inter and intra chain complexation. As the breaking and reforming of ionic bonds are time dependent, the hydrogels exhibit rate dependent mechanical behaviour. We systematically studied the tearing energy by tearing test with various tearing velocity under different temperature, and the linear viscoelastic behaviour over a wide range of frequency and temperature. Results have shown that the tearing energy markedly increase with the crack velocity and decrease with the measured temperature. In accordance with the prediction of Williams, Landel, and Ferry (WLF) rate-temperature equivalence, a master curve of tearing energy dependence of crack velocity can be well constructed using the same shift factor from the linear viscoelastic data. The scaling relation of tearing energy as a function of crack velocity can be predicted well by the rheological data according to the developed linear fracture mechanics.
Cha, Ruitao; Wang, Chengyu; Cheng, Shaoling; He, Zhibin; Jiang, Xingyu
2014-09-22
Specialty paper (e.g. cigarette paper and battery diaphragm paper) requires extremely high strength properties. The addition of strength agents plays an important role in increasing strength properties of paper. Nanocrystalline cellulose (NCC), or cellulose whiskers, has the potential to enhance the strength properties of paper via improving inter-fibers bonding. This paper was to determine the potential of using carboxylated nanocrystalline cellulose (CNCC) to improve the strength properties of paper made of cellulosic fiber or poly (vinyl alcohol) (PVA) fiber. The results indicated that the addition of CNCC can effectively improve the strength properties. At a CNCC dosage of 0.7%, the tear index and tensile index of the cellulosic paper reached the maximum of 12.8 mN m2/g and 100.7 Nm/g, respectively. More importantly, when increasing the CNCC dosage from 0.1 to 1.0%, the tear index and tensile index of PVA fiber paper were increased by 67.29%, 22.55%, respectively. Copyright © 2014 Elsevier Ltd. All rights reserved.
Thorlund, Jonas Bloch; Juhl, Carsten Bogh; Ingelsrud, Lina Holm; Skou, Søren Thorgaard
2018-05-01
This statement aimed at summarising and appraising the available evidence for risk factors, diagnostic tools and non-surgical treatments for patients with meniscal tears. We systematically searched electronic databases using a pragmatic search strategy approach. Included studies were synthesised quantitatively or qualitatively, as appropriate. Strength of evidence was determined according to the Grading of Recommendations Assessment Development and Evaluation framework. Low-quality evidence suggested that overweight (degenerative tears, k=3), male sex (k=4), contact and pivoting sports (k=2), and frequent occupational kneeling/squatting (k=3) were risk factors for meniscal tears. There was low to moderate quality evidence for low to high positive and negative predictive values, depending on the underlying prevalence of meniscal tears for four common diagnostic tests (k=15, n=2474). Seven trials investigated exercise versus surgery (k=2) or the effect of surgery in addition to exercise (k=5) for degenerative meniscal tears. There was moderate level of evidence for exercise improving self-reported pain (Effect Size (ES)-0.51, 95% CI -1.16 to 0.13) and function (ES -0.06, 95% CI -0.23 to 0.11) to the same extent as surgery, and improving muscle strength to a greater extent than surgery (ES -0.45, 95% CI -0.62 to -0.29). High-quality evidence showed no clinically relevant effect of surgery in addition to exercise on pain (ES 0.18, 95% 0.05 to 0.32) and function (ES, 0.13 95% CI -0.03 to 0.28) for patients with degenerative meniscal tears. No randomised trials comparing non-surgical treatments with surgery in patients younger than 40 years of age or patients with traumatic meniscal tears were identified. Diagnosis of meniscal tears is challenging as all clinical diagnostic tests have high risk of misclassification. Exercise therapy should be recommended as the treatment of choice for middle-aged and older patients with degenerative meniscal lesions. Evidence on the best treatment for young patients and patients with traumatic meniscal tears is lacking. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Laboratory Powder Metallurgy Makes Tough Aluminum Sheet
NASA Technical Reports Server (NTRS)
Royster, D. M.; Thomas, J. R.; Singleton, O. R.
1993-01-01
Aluminum alloy sheet exhibits high tensile and Kahn tear strengths. Rapid solidification of aluminum alloys in powder form and subsequent consolidation and fabrication processes used to tailor parts made of these alloys to satisfy such specific aerospace design requirements as high strength and toughness.
Lee, Ro Woon; Choi, Soo-Jung; Lee, Man Ho; Ahn, Jae Hong; Shin, Dong Rock; Kang, Chae Hoon; Lee, Ki Won
2016-12-01
To evaluate the diagnostic performance (DP) of 3T (3 Tesla field strength) conventional shoulder magnetic resonance imaging (MRI) in detecting the long head of the biceps tendon (LHBT) tears in association with rotator cuff tendon tears. This study included 80 consecutive patients who underwent arthroscopic surgery for rotator cuff tendon tears. Two radiologists independently evaluated the preoperative 3T shoulder MRI for the presence of LHBT tears. The DP of MRI was evaluated using the results of arthroscopy as the reference standard. We also evaluated the DP of several MR signs of LHBT in detection of partial LHBT tears. Arthroscopic examination revealed 35 partial and 5 complete tears. According to the results of evaluation by reviewers 1 and 2, shoulder MRI exhibited sensitivities of 77.14 and 80 % and specificities of 71.11 and 73.33 % in detection of partial LHBT tears and sensitivities of 80 and 100 % and a specificity of 100% (both) in detection of complete LHBT tears. In detecting partial LHBT tears, increased T2 signal intensity of the LHBT exhibited high sensitivities (reviewers 1 and 2; 82.85 and 80 %, respectively) and the presence of intratendinous defects or C-signs exhibited the highest specificities (reviewers 1 and 2; 95.55 and 93.33 %, respectively), followed by abnormalities in shape and outer margins of the LHBT (reviewers 1 and 2; 91.11 and 82 %; 91.11 and 86.66 %, respectively). Non-contrast-enhanced 3T shoulder MRI is potentially highly accurate in detection of complete LHBT tears, but moderately accurate in detection of partial LHBT tears.
Rehabilitation after a grade III latissimus dorsi tear of a soccer player: A case report.
Fysentzou, Christodoulos
2016-11-21
Latissimus dorsi, grade III tendon tears are an uncommon injury. There are very few cases reported in the literature, but most importantly, no cases could be found that relate to soccer. To present a successful, non-operative rehabilitation program for a professional athlete, after a grade III latissimus dorsi tear. A 37 year old healthy, elite professional soccer goalkeeper was injured during a championship game. The athlete fell on his left side with an outstretched and externally rotated upper extremity in order to catch a ball that was going very close to the left pole of his goal-post. After on-field and off-field clinical examinations, the diagnosis was a left latissimus dorsi tendon tear which was later confirmed by MRI as a grade III tear. During the first two weeks, intervention consisted of anti-inflammatory treatment and light therapeutic exercises. As the pain was subsiding and the strength was returning, the treatment shifted to purely strengthening and functional training. Four weeks after the injury, the athlete presented with pain 0/10 in all functional activities and full ROM in both active and passive movements. Before discharge, the athlete underwent a sport specific training program, without any complains, that cleared him to participate in normal training with the rest of the team. Three months after the injury the strength of the player's left shoulder was 5/5 in all movements. The protocol used yielded an accelerated return to sport (soccer) and function compared with other published research after a grade III latissimus dorsi tendon tear. One year later, the goalkeeper was still playing in the same competitive level without any re-injuries or complains, which means that this treatment protocol withstood the test of time.
Evaporation-driven instability of the precorneal tear film.
Peng, Cheng-Chun; Cerretani, Colin; Braun, Richard J; Radke, C J
2014-04-01
Tear-film instability is widely believed to be a signature of eye health. When an interblink is prolonged, randomly distributed ruptures occur in the tear film. "Black spots" and/or "black streaks" appear in 15 to 40 s for normal individuals. For people who suffer from dry eye, tear-film breakup time (BUT) is typically less than a few seconds. To date, however, there is no satisfactory quantitative explanation for the origin of tear rupture. Recently, it was proposed that tear-film breakup is related to locally high evaporative thinning. A spatial variation in the thickness of the tear-film lipid layer (TFLL) may lead to locally elevated evaporation and subsequent tear-film breakup. We examine the local-evaporation-driven tear-film-rupture hypothesis in a one-dimensional (1-D) model for the evolution of a thin aqueous tear film overriding the cornea subject to locally elevated evaporation at its anterior surface and osmotic water influx at its posterior surface. Evaporation rate depends on mass transfer both through the coating lipid layer and through ambient air. We establish that evaporation-driven tear-film breakup can occur under normal conditions but only for higher aqueous evaporation rates. Predicted roles of environmental conditions, such as wind speed and relative humidity, on tear-film stability agree with clinical observations. More importantly, locally elevated evaporation leads to hyperosmolar spots in the tear film and, hence, vulnerability to epithelial irritation. In addition to evaporation rate, tear-film instability depends on the strength of healing flow from the neighboring region outside the breakup region, which is determined by the surface tension at the tear-film surface and by the repulsive thin-film disjoining pressure. This study provides a physically consistent and quantitative explanation for the formation of black streaks and spots in the human tear film during an interblink. Copyright © 2013 Elsevier B.V. All rights reserved.
Craig, Edward V; Galatz, Leesa M; Sperling, John W
2014-01-01
Rotator cuff pathology and tearing remains a common cause of shoulder pain and disability. Although little controversy and disagreement exists regarding the treatment of small to moderate size tears in good quality tissue without retraction, there is difficulty in agreeing on the ideal treatment of the largest tears, particularly because those tears may be accompanied by widely variable levels of pain and function. Clinical decision making is made more difficult because of the variable presentations observed in patients with a documented full-thickness rotator cuff tear: some have good function and no pain, some have good function and pain, some have poor function and no pain, and some have both poor function and pain. The role of biologics as an adjunct in treating most rotator cuff tears remains unclear, with ongoing exploration of the roles of stem cells, growth factors, and platelet-rich plasma. In patients with unreconstructable tears with marked weakness in external rotation but good elevation, a latissimus transfer may restore rotation. Patches may play a role in partial repairs while serving as both a lattice for healing and a biomechanical anchoring point for sutures. In patients with massive tears and arthritis and in many who have rotator cuff insufficiency, pseudoparalysis, or anterosuperior escape without arthritis, reverse shoulder arthroplasty has led to improvements in pain and strength and revolutionized the treatment of rotator cuff tears.
Geyer, S; Schoch, C; Nelitz, M; Geyer, M
2015-08-01
The double-row rotator cuff repair is discussed controversially. Despite improved biomechanical properties, reduced re-tear rates and higher costs, no significant difference compared to single-row fixation in the clinical results is found. Mid-term results of an open double-row fixation with titanium anchor screws are presented. 237 patients (m = 142, f = 95, median age: 56.3 years) were operated in 2007 with this technique by the senior author (M. G.). Preoperatively, 2 years and 4,5 years postoperatively a subjective shoulder score (SSG) with follow-up rates of 86, 87 and 83 %, was evaluated. 5.1 years postoperatively an objective evaluation of 131 patients using the Constant-Murley scores (CS), the simple shoulder tests (SST), Gerber's shoulder value and the evaluation with school grades followed. The integrity of the cuff was checked with ultrasound. The absolute (re-tears and partial re-tears) and the relative (re-tears, partial re-tears, thinning and thickening of the cuff) re-tear rates were evaluated. In SSG a highly significant improvement from 51 to 83 points was found (p < 0.001). In CS 80 points (min.: 18; max.: 100), and in SST 11 points (min.: 2; max.: 12) were achieved. The shoulder value of Gerber increased significantly from preoperative 28.1 to 84.5 % 5.1 years postoperative (p < 0.001).The absolute re-tear rate, evaluated in ultrasound was 7.6 %, the relative re-tear rate 17.6 %. For primary rotator cuff reconstructions a higher CS with 82 points and a lower relative re-tear rate with 10.5 % were found. The patient's age had no significant influence on the clinical outcome. The rupture size showed a significant impact on the re-tear rate and the scores (p < 0.05). Between the operated and healthy shoulder neither strength nor mobility were found to be significantly different. Men reached a highly significant better strength than women (p < 0.001) which also resulted in a significantly better outcome in the CS (p < 0.01). The costs for open titanium transfixation technique with 330 € per case are markedly less than for arthroscopic suture bridge technique with 600 to 1000 € per case. Open double-row cuff repair with titanium screws is a safe and cost effective technique with a low re-tear rate with comparable clinical results regarding open and arthroscopic procedures. Georg Thieme Verlag KG Stuttgart · New York.
Effect of tulle on the mechanical properties of a maxillofacial silicone elastomer.
Gunay, Yumushan; Kurtoglu, Cem; Atay, Arzu; Karayazgan, Banu; Gurbuz, Cihan Cem
2008-11-01
The purpose of this research was to investigate if physical properties could be improved by incorporating a tulle reinforcement material into a maxillofacial silicone elastomer. A-2186 silicone elastomer was used in this study. The study group consisted of 20 elastomer specimens incorporated with tulle and fabricated in dumbbell-shaped silicone patterns using ASTM D412 and D624 standards. The control group consisted of 20 elastomer specimens fabricated without tulle. Tensile strength, ultimate elongation, and tear strength of all specimens were measured and analyzed. Statistical analyses were performed using Mann-Whitney U test with a statistical significance at 95% confidence level. It was found that the tensile and tear strengths of tulle-incorporated maxillofacial silicone elastomer were higher than those without tulle incorporation (p < 0.05). Therefore, findings of this study suggested that tulle successfully reinforced a maxillofacial silicone elastomer by providing it with better mechanical properties and augmented strength--especially for the delicate edges of maxillofacial prostheses.
Ferrer, Gerald A; Miller, R Matthew; Zlotnicki, Jason P; Tashman, Scott; Irrgang, James J; Musahl, Volker; Debski, Richard E
2018-01-01
Rotator cuff tears are a significant clinical problem, with exercise therapy being a common treatment option for patients. Failure rates of exercise therapy may be due to the failure to improve glenohumeral kinematics. Tears involving the supraspinatus may result in altered glenohumeral kinematics and joint instability for internal/external rotation with the arm at the side because not all muscles used to stabilize the glenohumeral joint are functioning normally. The objective of the study is to assess in vivo glenohumeral kinematic changes for internal/external rotation motions with the arm at the side of patients with a symptomatic full-thickness supraspinatus tear before and after a 12-week exercise therapy programme. Five patients underwent dynamic stereoradiography analysis before and after a 12-week exercise therapy protocol to measure changes in glenohumeral kinematics during transverse plane internal/external rotation with the arm at the side. Patient-reported outcomes and shoulder strength were also evaluated. No patient sought surgery immediately following exercise therapy. Significant improvements in isometric shoulder strength and patient-reported outcomes were observed (p < 0.05). No significant changes in glenohumeral kinematics following physical therapy were found. Isolated supraspinatus tears resulted in increased joint translations compared to healthy controls from the previous literature for internal/external rotation with the arm at the side. Despite satisfactory clinical outcomes following exercise therapy, glenohumeral kinematics did not change. The lack of changes may be due to the motion studied or the focus of current exercise therapy protocols being increasing shoulder strength and restoring range of motion. Current exercise therapy protocols should be adapted to also focus on restoring glenohumeral kinematics to improve joint stability since exercise therapy may have different effects depending on the motions of daily living. Prognostic study, Level II.
Kim, Sung-Jae; Choi, Yun-Rak; Jung, Min; Lee, Won-Yong; Chun, Yong-Min
2017-05-01
No previous study has examined whether isolated subscapularis tendon repair in irreparable posterosuperior massive rotator tears involving the subscapularis tendon in relatively young patients without arthritis can yield satisfactory outcomes. We hypothesized that this procedure would produce favorable outcomes in patients who might otherwise be candidates for reverse arthroplasty. Case series; Level of evidence, 4. This retrospective study included 24 patients in their 50s and 60s, without shoulder arthritis, who underwent arthroscopic isolated subscapularis repair for an irreparable massive rotator cuff tear involving the subscapularis tendon. Preoperative and postoperative visual analog scale (VAS) pain scores, subjective shoulder values (SSVs), University of California at Los Angeles (UCLA) shoulder scores, American Shoulder and Elbow Surgeons (ASES) scores, subscapularis strength (modified bell-press test; maximum of 5), and shoulder active range of motion (ROM) were assessed. Postoperative magnetic resonance arthrography (MRA) was performed 6 months postoperatively to assess structural integrity of the repaired subscapularis. At a mean 34.8 months (range, 24-49 months) of follow-up, VAS pain scores (improved from 7.1 to 2.5), SSVs (33.3 to 75.2), ASES scores (35.9 to 76.0), UCLA shoulder scores (11.6 to 24.8), subscapularis strength, and ROM were significantly improved compared with preoperative measurements ( P < .001). Subscapularis muscle strength improved from 3.7 to 4.2 ( P < .001). For active ROM, forward flexion and internal rotation improved significantly ( P < .001); however, external rotation exhibited no significant improvement. Follow-up MRA was performed in 22 patients (92%) and showed retear of the repaired subscapularis in 6 (27% of the 22). Isolated repair of the subscapularis tendon in irreparable massive rotator cuff tears involving the subscapularis tendon yielded satisfactory short-term outcomes and structural integrity in patients in their 50s and 60s without arthritis. If patients with irreparable massive rotator cuff tears involving the subscapularis tendon are relatively young or have minimal concomitant arthritis, this repair can be worthwhile.
Liu, Q; Shao, L Q; Xiang, H F; Zhen, D; Zhao, N; Yang, S G; Zhang, X L; Xu, J
2013-01-01
An ideal material for maxillofacial prostheses has not been found. We created a novel material: silicone elastomer filled with hollow microspheres and characterized its biomechanical properties. Expancel hollow microspheres were mixed with MDX4-4210 silicone elastomer using Q7-9180 silicone fluid as diluent. The volume fractions of microspheres were 0, 5, 15, and 30% v/v (volume ratio to the total volume of MDX4-4210 and microspheres). The microspheres dispersed well in the matrix. The physical properties and biocompatibility of the composites were examined. Shock absorption was the greatest by the 5% v/v composite, and decreased with increasing concentrations of microspheres. The density, thermal conductivity, Shore A hardness, tear and tensile strength decreased with increasing concentrations of microspheres, while elongation at break increased. Importantly, the tear strength of all composites was markedly lower than that of pure silicone elastomer. Cell viability assays indicated that the composite was of good biocompatibility. The composite with a volume fraction of 5% exhibited the optimal properties for use as a maxillofacial prosthesis, though its tear strength was markedly lower than that of silicone elastomer. In conclusion, we developed a novel light and soft material with good flexibility and biocompatibility, which holds a promising prospect for clinical application as maxillofacial prosthesis.
Effect of extraoral aging conditions on mechanical properties of maxillofacial silicone elastomer.
Hatamleh, Muhanad M; Polyzois, Gregory L; Silikas, Nick; Watts, David C
2011-08-01
The purpose of this study was to investigate the effect of extraoral human and environmental conditions on the mechanical properties (tensile strength and modulus, elongation, tear strength hardness) of maxillofacial silicone elastomer. Specimens were fabricated using TechSil-S25 silicone elastomer (Technovent Ltd, Leeds, UK). Eight groups were prepared (21 specimens in each group; eight tensile, eight tear, five hardness) and conditioned differently as follows (groups 1 through 8): Dry storage for 24 hours; dry storage in dark for 6 months; storage in simulated sebum solution for 6 months; storage in simulated acidic perspiration for 6 months; accelerated artificial daylight aging under controlled moisture for 360 hours; outdoor weathering for 6 months; storage in antimicrobial silicone-cleaning solution for 30 hours; and mixed conditioning of sebum storage and light aging for 360 hours. The conditioning period selected simulated a prosthesis being in service for up to 12 months. Tensile and tear test specimens were fabricated and tested according to the International Standards Organization (ISO) standards no. 37 and 34, respectively. Shore A hardness test specimens were fabricated and tested according to the American Standards for Testing and Materials (ASTM) D 2240. Data were analyzed with one-way ANOVA, Bonferroni, and Dunnett's T3 post hoc tests (p < 0.05). Weibull analysis was also used for tensile strength and tear strength. Statistically significant differences were evident among all properties tested. Mixed conditioning of simulated sebum storage under accelerated artificial daylight aging significantly degraded mechanical properties of the silicone (p < 0.05). Mechanical properties of maxillofacial elastomers are adversely affected by human and environmental factors. Mixed aging of storage in simulated sebum under accelerated daylight aging was the most degrading regime. Accelerated aging of silicone specimens in simulated sebum under artificial daylight for 12 months of simulated clinical service greatly affected functional properties of silicone elastomer; however, in real practice, the effect is modest, since sebum concentration is lower, and daylight is less concentrated. © 2011 by The American College of Prosthodontists.
Palisch, Andrew R; Winters, Ronald R; Willis, Marc H; Bray, Collin D; Shybut, Theodore B
2016-10-01
The menisci play an important biomechanical role in axial load distribution of the knees by means of hoop strength, which is contingent on intact circumferentially oriented collagen fibers and meniscal root attachments. Disruption of the meniscal root attachments leads to altered biomechanics, resulting in progressive cartilage loss, osteoarthritis, and subchondral edema, with the potential for development of a subchondral insufficiency fracture. Identification of meniscal root tears at magnetic resonance (MR) imaging is crucial because new arthroscopic surgical techniques (transtibial pullout repair) have been developed to repair meniscal root tears and preserve the tibiofemoral cartilage of the knee. An MR imaging classification of posterior medial meniscal root ligament lesions has been recently described that is dedicated to the posterior root of the medial meniscus. An arthroscopic classification of meniscal root tears has been described that can be applied to the anterior and posterior roots of both the medial meniscus and the lateral meniscus. This arthroscopic classification includes type 1, partial stable root tears; type 2, complete radial root tears; type 3, vertical longitudinal bucket-handle tears; type 4, complex oblique tears; and type 5, bone avulsion fractures of the root attachments. Knowledge of these classifications and the potential contraindications to meniscal root repair can aid the radiologist in the preoperative reporting of meniscal root tear types and the evaluation of the tibiofemoral cartilage. As more patients undergo arthroscopic repair of meniscal root tears, familiarity with the surgical technique and the postoperative radiographic and MR imaging appearance is important to adequately report the imaging findings. © RSNA, 2016.
Rotator cuff tear and sarcopenia: are these related?
Chung, Seok Won; Yoon, Jong Pil; Oh, Kyung-Soo; Kim, Hyung Sup; Kim, Young Gun; Lee, Hyun-Joo; Jeong, Won-Ju; Kim, Dong-Hyun; Lee, Jong Soo; Yoon, Jee Wook
2016-09-01
Sarcopenia is the loss of muscle mass and consequent loss of muscle function with aging. Its prevalence among the general population is 12% to 30% in those aged >60 years. We evaluated (1) the difference in the prevalence of sarcopenia between patients with rotator cuff tear and controls and (2) the sarcopenia severity according to the size of the rotator cuff tear. Group 1 included 48 consecutive patients with chronic symptomatic full-thickness rotator cuff tears (mean age, 60.1 ± 6.5 years; range, 46-76 years), and group 2 included 48 age- and sex-matched patients. The sarcopenic index was evaluated by using the grip strength of the asymptomatic contralateral side and the skeletal muscle mass. No significant differences were found in the baseline data and demographic factors between the groups. The sarcopenic index was significantly inferior in the rotator cuff tear group than in the age- and sex-matched control groups (P = .041, .007, and .05, respectively). Patients with large to massive tears had a significantly inferior sarcopenic index than those with small and medium tears. The results showed that sarcopenia was more severe in patients with a chronic symptomatic full-thickness rotator cuff tear than in the age- and sex-matched control population and was correlated with the size of the tear, with the numbers available. Despite the individual variance in the underlying medical condition and physical activities, this study suggests that clinicians should consider the sarcopenic condition of patients with a rotator cuff tear, especially in elderly patients with large to massive tears. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Physical Changes in Human Meibum with Age as Measured by Infrared Spectroscopy
Borchman, Douglas; Foulks, Gary N.; Yappert, Marta C.; Kakar, Shelly; Podoll, Nathan; Rychwalski, Paul; Schwietz, Eric
2010-01-01
Both lipids and mucins contribute to the stability of the tear film and lipids may inhibit tears from evaporating. Younger people have lower lipid viscosity, higher lipid volume, and a lower rate of tear evaporation. Since age-related changes in human meibum composition and conformation have never been investigated, as a basis for the study of lipid-associated changes with meibomian gland dysfunction, we used the power of infrared spectroscopy to characterize hydrocarbon chain conformation and packing in meibum from humans without dry eye symptoms in relation to age and sex. Meibum from normal human donors ranging in age from 3 to 88 years was studied. Meibum phase transitions were quantified by fitting them to a 4-parameter 2-state sigmoidal equation. Human meibum order and phase transition temperatures decrease with age and this trend may be attributed to lipid compositional changes. If meibum has the same thermodynamic properties on the surface of the tears as it does on the lid margin, a decrease in lipid-lipid interaction strength with increasing age could decrease the stability of tears since lipid-lipid interactions on the tear surface must be broken for the tear film to break up. This study also serves as a foundation to examine meibum conformational differences in meibum from people with meibomian gland dysfunction. PMID:20160464
Noyes, Matthew P; Ladermann, Alexandre; Denard, Patrick J
2017-09-01
To prospectively review functional outcomes and healing rates of large and massive rotator cuff tears repaired with a load-sharing rip-stop (LSRS) technique. Twenty-one consecutive patients underwent arthroscopic rotator cuff repair with an LSRS construct between January and December 2014. Seventeen patients with a minimum of 2 years' follow-up were included. Four patients did not complete clinical evaluations and functional outcome scores at a minimum of 2 years' follow-up and were lost to follow-up. Ultrasound imaging was used to assess for rotator cuff healing at a minimum of 6 months postoperatively. Range of motion, strength, and functional outcome scores were evaluated at final follow-up. Mean active forward elevation improved from 109° preoperatively to 153° postoperatively, and mean supraspinatus strength improved by 1 strength grade, from 3.5 preoperatively to 4.4 postoperatively. When we compared preoperative and postoperative values, the American Shoulder and Elbow Surgeons score improved from 40.8 to 89.5, the Single Assessment Numeric Evaluation score improved from 32.8 to 83.1, the Simple Shoulder Test score improved from 3.8 to 10.3, and the pain score on a visual analog scale decreased from 4.8 to 0.8 (P < .001). Of 17 patients, 13 (82%) were satisfied with their outcomes. Ultrasound evaluation 6 months after surgery showed complete healing in 53%, partial healing in 29%, and no healing in 18%. The LSRS construct showed satisfactory functional outcomes with reasonable healing rates in an otherwise challenging subset of rotator cuff tears. This construct may be an alternative for tears not amenable to double-row repair. Level IV, therapeutic case series. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Study of hot cracking potential in a 6-ton steel ingot casting
NASA Astrophysics Data System (ADS)
Yang, Jing'an; Liu, Baicheng; Shen, Houfa
2018-04-01
A new hot cracking potential (HCP) criterion, for the appearance of hot tearing in steel ingot castings, is proposed. The maximum value of the first principal stress, divided by the dynamic yield strength in the brittle temperature range (BTR), was used to identify the HCP. Experiments were carried out on a 6-ton P91 steel ingot in which severe hot tearing was detected in the upper centerline. Another ingot, with a better heat preservation riser, and without hot tearing, was used for comparison. Samples were obtained from the area of the ingot body with hot tearing, and their morphologies were inspected by a X-ray high energy industrial computed tomography. The carbon and sulfur distributions around the hot tearing were characterized by an infrared spectrometry carbon and sulfur analyzer. High temperature mechanical properties were obtained by a Gleeble thermal simulation machine, under different strain rates. Then, thermo-mechanical simulations using an elasto-viscoplastic finite-element model were conducted to analyze the stress and strain evolution during ingot solidification. The results showed that the hot tearing area, which was rich in both carbon and sulfur, was under excessive tensile stress in the BTR, bearing the highest HCP.
Miyazaki, Tatsuya; Miyauchi, Satoshi; Matsuzaka, Satoshi; Yamagishi, Chie; Kobayashi, Kohei
2010-05-01
Tissue-engineered cartilage may be expected to serve as an alternative to autologous chondrocyte transplantation treatment. Several methods for producing cartilaginous tissue have been reported. In this study, we describe the production of scaffold-free stiff cartilaginous tissue of pig and human, using allogeneic serum and growth factors. The tissue was formed in a mold using chondrocytes recovered from alginate bead culture and maintained in a medium with transforming growth factor-beta and several other additives. In the case of porcine tissue, the tear strength of the tissue and the contents of proteoglycan (PG) and collagen per unit of DNA increased dose-dependently with transforming growth factor-beta. The length of culture was significantly and positively correlated with thickness, tear strength, and PG and collagen contents. Tear strength showed positive high correlations with both PG and collagen contents. A positive correlation was also seen between PG content and collagen content. Similar results were obtained with human cartilaginous tissue formed from chondrocytes expanded in monolayer culture. Further, an in vivo pilot study using pig articular cartilage defect model demonstrated that the cartilaginous tissue was well integrated with surrounding tissue at 13 weeks after the implantation. In conclusion, we successfully produced implantable scaffold-free stiff cartilaginous tissue, which characterized high PG and collagen contents.
Charousset, Christophe; Zaoui, Amine; Bellaïche, Laurence; Piterman, Michel
2014-04-01
To evaluate the clinical and magnetic resonance imaging (MRI) outcome of arthroscopic rotator cuff repair with the use of leukocyte-platelet-rich plasma (L-PRP) in patients with large or massive rotator cuff tears. A comparative cohort of patients with large or massive rotator cuff tears undergoing arthroscopic repair was studied. Two consecutive groups of patients were included: rotator cuff repairs with L-PRP injection (group 1, n = 35) and rotator cuff repairs without L-PRP injection (group 2, n = 35). A double-row cross-suture cuff repair was performed by a single surgeon with the same rehabilitation protocol. Patients were clinically evaluated with the Constant score; Simple Shoulder Test score; University of California, Los Angeles (UCLA) score; and strength measurements by use of a handheld dynamometer. Rotator cuff healing was evaluated by postoperative MRI using the Sugaya classification (type 1 to type 5). We prospectively evaluated the 2 groups at a minimum 2-year follow-up. The results did not show differences in cuff healing between the 2 groups (P = .16). The size of recurrent tears (type 4 v type 5), however, was significantly smaller in group 1 (P = .008). There was no statistically significant difference in the recurrent tear rate (types 4 and 5) between the 2 groups (P = .65). There was no significant difference between group 1 and group 2 in terms of University of California, Los Angeles score (29.1 and 30.3, respectively; P = .90); Simple Shoulder Test score (9.9 and 10.2, respectively; P = .94); Constant score (77.3 and 78.1, respectively; P = .82); and strength (7.5 and 7.0, respectively; P = .51). In our study the use of autologous L-PRP did not improve the quality of tendon healing in patients undergoing arthroscopic repair of large or massive rotator cuff tears based on postoperative MRI evaluation. The only significant advantage was that the L-PRP patients had smaller iterative tears. However, the functional outcome was similar in the 2 groups of patients. Level III, case-control study. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Wieschhoff, Ged G; Mandell, Jacob C; Czuczman, Gregory J; Nikac, Violeta; Shah, Nehal; Smith, Stacy E
2017-11-01
Hamstring muscle deficiency is increasingly recognized as a risk factor for anterior cruciate ligament (ACL) tears. The purpose of this study is to evaluate the vastus medialis to semimembranosus cross-sectional area (VM:SM CSA) ratio on magnetic resonance imaging (MRI) in patients with ACL tears compared to controls. One hundred knee MRIs of acute ACL tear patients and 100 age-, sex-, and side-matched controls were included. Mechanism of injury, contact versus non-contact, was determined for each ACL tear subject. The VM:SM CSA was measured on individual axial slices with a novel method using image-processing software. One reader measured all 200 knees and the second reader measured 50 knees at random to assess inter-reader variability. The intraclass correlation coefficient (ICC) was calculated to evaluate for correlation between readers. T-tests were performed to evaluate for differences in VM:SM CSA ratios between the ACL tear group and control group. The ICC for agreement between the two readers was 0.991 (95% confidence interval 0.984-0.995). Acute ACL tear patients have an increased VM:SM CSA ratio compared to controls (1.44 vs. 1.28; p = 0.005). Non-contact acute ACL tear patients have an increased VM:SM CSA ratio compared to controls (1.48 vs. 1.20; p = 0.003), whereas contact acute ACL tear patients do not (1.23 vs. 1.26; p = 0.762). Acute non-contact ACL tears are associated with increased VM:SM CSA ratios, which may imply a relative deficiency in hamstring strength. This study also demonstrates a novel method of measuring the relative CSA of muscles on MRI.
Burkhart, Stephen S; Denard, Patrick J; Konicek, John; Hanypsiak, Bryan T
2014-02-01
Poor-quality tendon is one of the most difficult problems the surgeon must overcome in achieving secure fixation during rotator cuff repair. A load-sharing rip-stop construct (LSRS) has recently been proposed as a method for improving fixation strength, but the biomechanical properties of this construct have not yet been examined. To compare the strength of the LSRS construct to that of single-row fixation for rotator cuff repair. Controlled laboratory study. Rotator cuff tears were created in 6 cadaveric matched-pair specimens and repaired with a single row or an LSRS. In the LSRS repair, a 2-mm suture tape was placed as an inverted mattress stitch in the rotator cuff, and sutures from 2 anchors were placed as simple stitches that passed medial to the suture tape. The suture tape limbs were secured with knotless anchors laterally before sutures were tied from the medial anchors. Displacement was observed with video tracking after cyclic loading, and specimens were loaded to failure. The mean load to failure was 371 ± 102 N in single-row repairs compared with 616 ± 185 N in LSRS repairs (P = .031). There was no difference in displacement with cyclic loading between the groups (3.3 ± 0.8 mm vs. 3.5 ± 1.1 mm; P = .561). In the single-row group, 4 of 6 failures occurred at the suture-tendon interface. In the LSRS group, only 1 failure occurred at the suture-tendon interface. The ultimate failure load of the LSRS construct for rotator cuff repair was 1.7 times that of a single-row construct in a cadaveric model. The LSRS rotator cuff repair construct may be useful in the repair of difficult tears such as massive tears, medial tears, and tears with tendon loss.
Predictors of degenerative medial meniscus extrusion: radial component and knee osteoarthritis.
Lee, Dae-Hee; Lee, Bum-Sik; Kim, Jong-Min; Yang, Kyung-Sook; Cha, Eun-Jong; Park, Ji-Hun; Bin, Seong-Il
2011-02-01
the purpose of this study was to determine the effect of a radial tear on degenerative medial meniscus posterior horn tear extrusion and to identify predictors of medial meniscus extrusion. we reviewed the records of 102 knees with medial meniscus posterior horn tears and degeneration that underwent a partial meniscectomy. Tears were classified as root (n = 17) and non-root (n = 85) tears, or as radial (n = 46) and non-radial (n = 56) tears. Groups were compared in terms of absolute and relative meniscal extrusion, and the proportion of knees with major (> 3 mm) extrusion. Multiple regression analysis was used to identify predictors of extrusion. the radial group had greater mean absolute (4 ± 1 vs. 3 ± 1 mm, P = 0.001) and relative (31 ± 11 vs. 23 ± 12%, P = 0.031) extrusion than the non-radial group. The radial group also had a greater proportion of major extrusions than the non-radial group (74% vs. 26%; P = 0.016). In contrast, the root tear and non-root tear groups were similar in terms of mean absolute (3 ± 1 vs. 3 ± 1 mm, P = n.s.) and relative (30 ± 7 vs. 26 ± 13%; P = n.s.) extrusion and in terms of proportion with major extrusions (59 vs. 55%; P = n.s.). Extrusion was found to be associated with a similar strength with both the presence of a radial component and the preoperative Kellgren-Lawrence grade. meniscal extrusion was greater and more severe in knees with a radial tear component than in knees without a radial component. The incidence and degree of major extrusion was similar in knees with root tears and non-root tears. A radial component and knee osteoarthritis severity were similarly predictive of absolute and relative extrusion. Meniscal extrusion in osteoarthritic knees was associated not only with degenerative meniscal tear but also with osteoarthritis severity. Therefore, arthroscopic meniscal procedures, especially meniscal repair, should be cautiously considered in patients with meniscal extrusion.
Should massive rotator cuff tears be reconstructed even when only partially repairable?
Godenèche, Arnaud; Freychet, Benjamin; Lanzetti, Riccardo Maria; Clechet, Julien; Carrillon, Yannick; Saffarini, Mo
2017-07-01
(1) To evaluate midterm functional outcomes of arthroscopic repair of massive rotator cuff tears and (2) to determine the prognostic factors that could influence outcome. The hypothesis was that both partial and complete repairs would result in equivalent improvement of clinical score. From a prospective series of 525 rotator cuff repairs, we analysed records of the 73 patients who were treated for massive tears. The median follow-up was 41 months (range 29-55), and functional outcome was evaluated using the Constant score, shoulder strength, and subjective shoulder value. The median CS improved from 34 points to 81 points (p < 0.001). The scores were better for both types of two-tendon tears, posterosuperior (83, n = 33) and anterosuperior (85, n = 13) (n.s.), than for three-tendon tears (74, n = 27) (p < 0.001). The scores were also better when fatty infiltration was of stage I (84, n = 28) than of stage II (78, n = 34) (p < 0.001) or stage III (74, n = 11) (p = 0.04). The scores were only slightly higher for completely reparable tears (81.5, n = 50) than for partially reparable tears (79, n = 23) (n.s.). Ultrasonic examination revealed incomplete healing, in 10 of the 50 completely repaired tears, and in 11 of the 23 partially repaired tears. The results of the present study compare favourably with those in recent literature and confirm the hypothesis that both partial and complete repairs of massive rotator cuff tears produce equivalent improvements of Constant scores. The clinical relevance of these observations is that even if repairs of two-tendon tears result in superior functional outcomes, repairs of three-tendon tears produce equivalent 'relative' improvement that grants sufficient patient satisfaction and autonomy. Comparative case series, Level IV.
Endoscopic repair of tears of the superficial layer of the distal triceps tendon.
Heikenfeld, Roderich; Listringhaus, Rico; Godolias, Georgios
2014-07-01
The purpose of this study was to evaluate the results after endoscopic repair of partial superficial layer triceps tendon tears. Fourteen patients treated surgically between July 2005 and December 2012 were studied prospectively for 12 months. Indication for surgery was a partial detachment of the triceps tendon from the olecranon that was proved by magnetic resonance imaging (MRI) in all cases. Ten of these patients had chronic olecranon bursitis. All patients were treated with endoscopic surgery including bursectomy and repair of the distal triceps tendon with double-loaded suture anchors. Clinical examination of the patients as well as functional and subjective scores (Mayo Elbow Performance Index [MEPI], Disabilities of the Arm, Shoulder and Hand Score [Quick DASH]) were obtained preoperatively and postoperatively at 6 and 12 months. An isokinetic strength measurement and MRI were performed preoperatively and 12 months after surgery. All 14 patients were completely evaluated. The MEPI and Quick DASH Score improved significantly after the repair at all postoperative examinations. The MEPI gained 29 points, up to 96 points at last follow-up (P < .05), and the Quick DASH Score went down 15.6 points after 12 months to 4.5 points (P < .05). Maximum extension power improved 55.8%, up to 94.7% at last follow-up compared with the contralateral side. Using MRI, we found one reruptured partial tear of the triceps tendon that did not require revision surgery. Although triceps tendon ruptures are generally uncommon, partial superficial tears might be more common than previously described. Once the diagnosis is made, endoscopic repair is a method leading to good clinical results with improved function of the affected elbow. Endoscopic repair of superficial tears of the triceps tendon is able to restore function and strength and leads to excellent clinical results after 1 year. Strength recovers to nearly that of the contralateral side, and serious complications appear to be infrequent. Level IV, therapeutic case series. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Saito, Taichi; Malay, Sunitha; Chung, Kevin C
2017-11-01
Evidence regarding the effectiveness of arthroscopic débridement for a triangular fibrocartilage complex tear is uncertain. The purpose of this study was to conduct a systematic review of outcomes to evaluate the effectiveness of débridement for triangular fibrocartilage complex tears. The authors searched all available literature in the PubMed, Embase, and MEDLINE (Ovid) databases for articles reporting on triangular fibrocartilage complex tear débridement. Data collection included arc of motion, grip strength, patient-reported outcomes, and complications. A total of 1723 unique studies were identified, of which 18 studies met the authors' criteria. The mean before and after arc of wrist extension/flexion motion values were 120 and 146 degrees (six studies). The mean before and after grip strength values were 65 percent and 91 percent of the contralateral side (10 studies). Disabilities of the Arm, Shoulder, and Hand scores (six studies) and pain visual analogue scale scores (seven studies) improved from 39 to 18, and from 7 to 3, respectively. The mean pain visual analogue scale score after débridement was 1.9 in the ulnar-positive group and 2.4 in the ulnar-neutral and ulnar-negative groups. Eighty-seven percent of patients returned to their original work. Patients reported reduced pain and improved functional and patient-reported outcomes after débridement of triangular fibrocartilage complex tears. Most patients after débridement returned to previous work, with few complications. Although some of these cases may require secondary procedures, simple débridement can be performed with suitable satisfactory outcomes for cases with any type of ulnar variance.
Potential of near-infrared spectroscopy for quality evaluation of cattle leather.
Braz, Carlos Eduardo M; Jacinto, Manuel Antonio C; Pereira-Filho, Edenir R; Souza, Gilberto B; Nogueira, Ana Rita A
2018-05-09
Models using near-infrared spectroscopy (NIRS) were constructed based on physical-mechanical tests to determine the quality of cattle leather. The following official parameters were used, considering the industry requirements: tensile strength (TS), percentage elongation (%E), tear strength (TT), and double hole tear strength (DHS). Classification models were constructed with the use of k-nearest neighbor (kNN), soft independent modeling of class analogy (SIMCA), and partial least squares-discriminant analysis (PLS-DA). The evaluated figures of merit, accuracy, sensitivity, and specificity presented results between 85% and 93%, and the false alarm rates from 9% to 14%. The model with lowest validation percentage (92%) was kNN, and the highest was PLS-DA (100%). For TS, lower values were obtained, from 52% for kNN and 74% for SIMCA. The other parameters %E, TT, and DHS presented hit rates between 87 and 100%. The abilities of the models were similar, showing they can be used to predict the quality of cattle leather. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhang, W.; Wang, S.; Ma, Z. W.
2017-06-01
The influences of helical driven currents on nonlinear resistive tearing mode evolution and saturation are studied by using a three-dimensional toroidal resistive magnetohydrodynamic code (CLT). We carried out three types of helical driven currents: stationary, time-dependent amplitude, and thickness. It is found that the helical driven current is much more efficient than the Gaussian driven current used in our previous study [S. Wang et al., Phys. Plasmas 23(5), 052503 (2016)]. The stationary helical driven current cannot persistently control tearing mode instabilities. For the time-dependent helical driven current with f c d = 0.01 and δ c d < 0.04 , the island size can be reduced to its saturated level that is about one third of the initial island size. However, if the total driven current increases to about 7% of the total plasma current, tearing mode instabilities will rebound again due to the excitation of the triple tearing mode. For the helical driven current with time dependent strength and thickness, the reduction speed of the radial perturbation component of the magnetic field increases with an increase in the driven current and then saturates at a quite low level. The tearing mode is always controlled even for a large driven current.
Mallegni, Norma; Phuong, Thanh Vu; Coltelli, Maria-Beatrice
2018-01-01
Poly(lactic acid) (PLA) was melt mixed in a laboratory extruder with poly(butylene adipate-co-terephthalate) (PBAT) and poly(butylene succinate) (PBS) in the presence of polypropylene glycol di glycidyl ether (EJ400) that acted as both plasticizer and compatibilizer. The process was then scaled up in a semi-industrial extruder preparing pellets having different content of a nucleating agent (LAK). All of the formulations could be processed by blowing extrusion and the obtained films showed mechanical properties dependent on the LAK content. In particular the tearing strength showed a maximum like trend in the investigated composition range. The films prepared with both kinds of blends showed a tensile strength in the range 12–24 MPa, an elongation at break in the range 150–260% and a significant crystallinity. PMID:29342099
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goldberg, A.; Lesuer, D.R.; Patt, J.
Experimental results, together with an analytical model, related to the loss in tensile strength of styrene-butadiene rubber (SBR) loaded with carbon black (CB) that had been subjected to low-cycle, high-stress fatigue tests were presented in a prior paper. The drop in tensile strength relative to that of a virgin sample was considered to be a measure of damage induced during the fatigue test. The present paper is a continuation of this study dealing with the morphological interpretations of the fractured surfaces, whereby the cyclic-tearing behavior, resulting in the damage, is related to the test and material parameters. It was foundmore » that failure is almost always initiated in the bulk of a sample at a material flaw. The size and definition of a flaw increase with an increase in carbon-black loading. Initiation flaw sites are enveloped by fan-shaped or penny-shaped regions which develop during cycling. The size and morphology of a fatigue-tear region appears to be independent of the fatigue load or the extent of the damage (strength loss). By contrast, either an increase in cycling load or an increase in damage at constant load increases the definition of the fatigue-region morphology for all formulations of carbon-black. On the finest scale, the morphology can be described in terms of tearing of individual groups of rubber strands, collapsing to form a cell-like structure. 18 refs., 13 figs.« less
Charles W. McMillin
1969-01-01
Burst and tear strengths of handsheets made from 48 pulps disk-refined from chips of varying chemical composition decreased with incressing extractive content after the independent effects of fiber morphology were specified. This result was attributed to lessened bond strength caused by reduced surface tension forces and blocking of reactive sites on the fiber surfaces...
Tear Strength and Tensile Strength of Model Filled Elastomers.
1980-04-10
X4PWQ Approved for public release; distribution unlimited 17. DISTRIUUTIO" STATEMENT (of Cho abm ,.. uo lm 8016401 Stock ". If 1eral b Rd~M) 0S...5011 Eisenhower Ave. Rm 8N4-2 Alexandria, VA 22333Naval Sea Sytems Command 1 Washington, D.C. 20362 Att : Mr. R. Beauregard SEA 64E Commander 1Naval
NASA Technical Reports Server (NTRS)
Falcone, Anthony; Laakso, John H.
1993-01-01
Adhesive bonding materials and processes were evaluated for assembly of future high-temperature aluminum alloy structural components such as may be used in high-speed civil transport aircraft and space launch vehicles. A number of candidate high-temperature adhesives were selected and screening tests were conducted using single lap shear specimens. The selected adhesives were then used to bond sandwich (titanium core) test specimens, adhesive toughness test specimens, and isothermally aged lap shear specimens. Moderate-to-high lap shear strengths were obtained from bonded high-temperature aluminum and silicon carbide particulate-reinforced (SiC(sub p)) aluminum specimens. Shear strengths typically exceeded 3500 to 4000 lb/in(sup 2) and flatwise tensile strengths exceeded 750 lb/in(sup 2) even at elevated temperatures (300 F) using a bismaleimide adhesive. All faceskin-to-core bonds displayed excellent tear strength. The existing production phosphoric acid anodize surface preparation process developed at Boeing was used, and gave good performance with all of the aluminum and silicon carbide particulate-reinforced aluminum alloys investigated. The results of this program support using bonded assemblies of high-temperature aluminum components in applications where bonding is often used (e.g., secondary structures and tear stoppers).
In Vivo Shoulder Function After Surgical Repair of a Torn Rotator Cuff
Bey, Michael J.; Peltz, Cathryn D.; Ciarelli, Kristin; Kline, Stephanie K.; Divine, George W.; van Holsbeeck, Marnix; Muh, Stephanie; Kolowich, Patricia A.; Lock, Terrence R.; Moutzouros, Vasilios
2015-01-01
Background Surgical repair of a torn rotator cuff is based on the belief that repairing the tear is necessary to restore normal glenohumeral joint (GHJ) mechanics and achieve a satisfactory clinical outcome. Hypothesis Dynamic joint function is not completely restored by rotator cuff repair, thus compromising shoulder function and potentially leading to long-term disability. Study Design Controlled laboratory study and Case series; Level of evidence, 4. Methods Twenty-one rotator cuff patients and 35 control participants enrolled in the study. Biplane radiographic images were acquired bilaterally from each patient during coronal-plane abduction. Rotator cuff patients were tested at 3, 12, and 24 months after repair of a supraspinatus tendon tear. Control participants were tested once. Glenohumeral joint kinematics and joint contact patterns were accurately determined from the biplane radiographic images. Isometric shoulder strength and patient-reported outcomes were measured at each time point. Ultrasound imaging assessed rotator cuff integrity at 24 months after surgery. Results Twenty of 21 rotator cuff repairs appeared intact at 24 months after surgery. The humerus of the patients’ repaired shoulder was positioned more superiorly on the glenoid than both the patients’ contralateral shoulder and the dominant shoulder of control participants. Patient-reported outcomes improved significantly over time. Shoulder strength also increased over time, although strength deficits persisted at 24 months for most patients. Changes over time in GHJ mechanics were not detected for either the rotator cuff patients’ repaired or contralateral shoulders. Clinical outcome was associated with shoulder strength but not GHJ mechanics. Conclusion Surgical repair of an isolated supraspinatus tear may be sufficient to keep the torn rotator cuff intact and achieve satisfactory patient-reported outcomes, but GHJ mechanics and shoulder strength are not fully restored with current repair techniques. Clinical Relevance The study suggests that current surgical repair techniques may be effective for reducing pain but have not yet been optimized for restoring long-term shoulder function. PMID:21737834
Arthroscopic Medial Meniscus Posterior Root Fixation Using a Modified Mason-Allen Stitch.
Chung, Kyu Sung; Ha, Jeong Ku; Ra, Ho Jong; Kim, Jin Goo
2016-02-01
A complete radial tear of the meniscus posterior root, which can effectively cause a state of total meniscectomy via loss of hoop tension, requires that the torn root be repaired. Several methods have been used to repair medial meniscus posterior root tears, most of which are based on a simple stitch technique that is known to have stitch-holding strength. We applied a modified version of the Mason-Allen stitch technique, which is recognized as a method for rotator cuff repair surgery because its locking effect overcomes the potential weakness of simple stitches. This article introduces the medial meniscus posterior root tears repair procedure based on a modified Mason-Allen stitch technique in which 2 strands (i.e., 1 simple horizontal and 1 simple vertical stitch) are used.
McCormick, Frank; Gupta, Anil; Bruce, Ben; Harris, Josh; Abrams, Geoff; Wilson, Hillary; Hussey, Kristen; Cole, Brian J.
2014-01-01
Purpose: The purpose of this study was to measure and compare the subjective, objective, and radiographic healing outcomes of single-row (SR), double-row (DR), and transosseous equivalent (TOE) suture techniques for arthroscopic rotator cuff repair. Materials and Methods: A retrospective comparative analysis of arthroscopic rotator cuff repairs by one surgeon from 2004 to 2010 at minimum 2-year followup was performed. Cohorts were matched for age, sex, and tear size. Subjective outcome variables included ASES, Constant, SST, UCLA, and SF-12 scores. Objective outcome variables included strength, active range of motion (ROM). Radiographic healing was assessed by magnetic resonance imaging (MRI). Statistical analysis was performed using analysis of variance (ANOVA), Mann — Whitney and Kruskal — Wallis tests with significance, and the Fisher exact probability test <0.05. Results: Sixty-three patients completed the study requirements (20 SR, 21 DR, 22 TOE). There was a clinically and statistically significant improvement in outcomes with all repair techniques (ASES mean improvement P = <0.0001). The mean final ASES scores were: SR 83; (SD 21.4); DR 87 (SD 18.2); TOE 87 (SD 13.2); (P = 0.73). There was a statistically significant improvement in strength for each repair technique (P < 0.001). There was no significant difference between techniques across all secondary outcome assessments: ASES improvement, Constant, SST, UCLA, SF-12, ROM, Strength, and MRI re-tear rates. There was a decrease in re-tear rates from single row (22%) to double-row (18%) to transosseous equivalent (11%); however, this difference was not statistically significant (P = 0.6). Conclusions: Compared to preoperatively, arthroscopic rotator cuff repair, using SR, DR, or TOE techniques, yielded a clinically and statistically significant improvement in subjective and objective outcomes at a minimum 2-year follow-up. Level of Evidence: Therapeutic level 3. PMID:24926159
Jeon, Yoon Sang; Lee, Juyeob; Kim, Rag Gyu; Ko, Young-Won; Shin, Sang-Jin
2017-11-01
The repair of anterior L-shaped tears is usually difficult because of the lack of anterior rotator cuff tendon to cover the footprint. The biceps tendon is usually exposed from the retracted anterolateral corner of the torn tendon and can be easily used to augment rotator cuff repair. Hypothesis/Purpose: This study compared the clinical outcomes of the biceps augmentation technique with those of partial tendon repair for the arthroscopic treatment of large anterior L-shaped rotator cuff tears to evaluate the role of additional biceps augmentation in tendon healing. We hypothesized that the biceps augmentation technique would lead to a lower rotator cuff tendon retear rate and provide satisfactory functional outcomes. Cohort study; Level of evidence, 3. This study included 64 patients with anterior L-shaped rotator cuff tears who underwent arthroscopic repair. Patients were divided into 2 groups: group A (31 patients) underwent repair of an anterior L-shaped tear combined with biceps augmentation, and group B (33 patients) had a partially repaired tendon whose footprint was exposed after repair without undue tension on the retracted tendon. Clinical evaluations were performed using the American Shoulder and Elbow Surgeons (ASES) score, Constant score, muscle strength, visual analog scale for pain, and patient satisfaction. Magnetic resonance imaging (MRI) was performed for tendon integrity at 6 months postoperatively. The mean period of follow-up was 29.1 ± 3.5 months (range, 24-40 months). The mean ASES and Constant scores significantly improved from 52.8 ± 10.6 and 43.2 ± 9.9 preoperatively to 88.2 ± 6.9 and 86.8 ± 6.2 at final follow-up in group A ( P < .001) and from 53.0 ± 11.8 and 44.3 ± 11.3 preoperatively to 87.4 ± 7.2 and 87.9 ± 7.3 at final follow-up in group B ( P < .001). Overall muscle strength (given as % of the other side's strength) significantly increased from preoperatively to final follow-up in group A (forward flexion [FF]: 62.0 ± 8.2 to 89.0 ± 8.6; external rotation [ER]: 57.5 ± 9.9 to 86.8 ± 9.3; internal rotation [IR]: 68.1 ± 10.8 to 88.1 ± 8.4; P < .001) and group B (FF: 59.9 ± 9.6 to 87.7 ± 9.0; ER: 58.6 ± 9.3 to 86.2 ± 7.5; IR: 70.0 ± 9.3 to 87.0 ± 8.4; P < .001). Twenty-one patients (67.7%) in group A and 20 patients (60.6%) in group B showed a healed rotator cuff tendon on postoperative MRI. The retear rate between the 2 groups showed no significant difference ( P = .552). Regarding clinical outcomes, both groups had no significant difference in the ASES score ( P = .901), Constant score ( P = .742), and muscle strength. There was no significant difference in the clinical outcomes and retear rate of anterior L-shaped tears between biceps augmentation and partial tendon repair. Additional biceps augmentation proved to have no enhancement in tendon healing. A precise method such as only partial tendon repair for reducing the footprint exposure without undue tension may be considered as one of the treatment options for large anterior L-shaped rotator cuff tears.
Nance, Erin; Ayalon, Omri; Yang, Steven
2016-06-01
We present a series of eight patients who underwent wrist arthroscopy for presumed solitary tears of the triangular fibrocartilage (TFC) and were, instead, found to have combined 1A (central tear) and 1B (ulnar avulsion) tears. The Palmer Classification does not currently categorize this combined pattern. All but one patient had a traumatic injury. Each subject had preoperative radiographs and MRI scans. TFC tears were evident on all MRI scans, though only one was suggestive of a combined tear pat - tern. Surgical management included arthroscopic central tear debridement and ulnar peripheral repair. Average follow-up was 22 months. Grip strength in the affected hand improved from 16% deficit as compared to the unaffected side, to 3.5% deficit postoperatively (p = 0.003), and visual analog scores (VAS) decreased from an average of 7.1/10 preoperatively to 2.3/10 postoperatively (p < 0.001). There was no statistically significant change in wrist range of motion (ROM), however. Arthroscopic debridement of the central perforation (1A lesion) with concomitant repair of the ulnar detachment (1B lesion) resulted in functional and symptomatic improvement. This combined 1A/1B TFC injury is not reliably diagnosed preoperatively and should be considered a new subset in the Palmer classification, as this will raise awareness of its presence and assist in preoperative planning of such lesions.
Repeatability of a new method for measuring tear evaporation rates.
Petznick, Andrea; Tan, Jen Hong; Boo, Shiao Khee; Lee, Sze Yee; Acharya, U Rajendra; Tong, Louis
2013-04-01
The purpose of this study was to evaluate the repeatability of tear evaporimetry based on infrared thermography in a clinical room setting and to test the effect of changing environmental humidity on ocular surface temperature (OST) and tear evaporation rates (TERs) in a controlled adverse environmental (CAE) chamber. Twenty-six healthy participants were enrolled, of whom 16 underwent repeatability measurements in a clinical room and 10 were exposed to a constant temperature of 30°C with a humidity of 45 and 65% in a CAE. Participants were acclimatized to each condition for at least 20 minutes before OSTs were taken. Tear film breakup time was assessed in the CAE only. Number of blinks and OSTs were continuously measured for 20 seconds for the cornea, conjunctiva, and overall ocular surface with an infrared camera; corresponding TERs were calculated. The OSTs and TERs showed acceptable strength of agreement between the first and second measurements. The coefficients of repeatability were 0.4°C for OST and 6.0 W m for TER. An increase in chamber humidity (from 45 to 65%) increased OST (p < 0.05). The TER was not changed significantly (p > 0.05). The tear film breakup time and number of blinks were not significantly affected by different humidity conditions. This technique has acceptable repeatability and has potential to document individual tear evaporation changes with time where humidity may differ by less than 20%.
Han, Ying; Kiat-amnuay, Sudarat; Powers, John M; Zhao, Yimin
2008-12-01
Contemporary silicone-based elastomeric prostheses tend to degrade over time because of the effect of mechanical loading. Little has been reported on how the mechanical properties of a maxillofacial prosthetic elastomer may be affected by the addition of nanosized oxide particles used as an opacifier. The purpose of this study was to evaluate the effect of different concentrations of nanosized oxides of various composition on the mechanical properties of a commercially available silicone elastomer. Nanosized oxides (Ti, Zn, or Ce) were added in various concentrations (0.5%, 1.0%, 1.5%, 2.0%, 2.5%, or 3.0% by weight) to a commercial silicone elastomer (A-2186), commonly used for fabricating extraoral maxillofacial prostheses. Silicone elastomer A-2186 without nanosized oxides served as a control group. Specimens (n=5) were polymerized according to manufacturer's recommendations and tested for tensile strength (ASTM D412) and tear strength (ASTM D624), and percent elongation in a universal testing machine. Uniformity of particle dispersion within the processed elastomer was assessed using scanning electron microscopic imaging. For each property, a 2-way ANOVA was performed evaluating the effect of oxide type and strength, and Fisher's PLSD test was used for pairwise comparisons (alpha=.05). SEM examination indicated that all 3 nanosized oxides distribute evenly throughout the silicone specimens, except for the 3.0% group, which are partly agglomerated. The 2.0% and 2.5% groups of all nanosized oxides demonstrated significantly higher tensile and tear strengths and percent elongation (P<.001) than the control group. CeO(2) had significantly lower tensile strength than TiO2 and ZnO (P<.05). The ZnO group had significantly higher tear strength than TiO(2) and CeO(2) (P <.05). Most of specimens became somewhat harder when compared with the control group. CeO(2) group had significantly higher Shore A hardness than TiO(2) and ZnO (P<.001). There was no significant difference of percent elongation among the type of nanosized oxides. Incorporation of Ti, Zn, or Ce nano-oxides at concentrations of 2.0% and 2.5% improved the overall mechanical properties of the silicone A-2186 maxillofacial elastomer.
Dry eye symptoms align more closely to non-ocular conditions than to tear film parameters.
Galor, Anat; Felix, Elizabeth R; Feuer, William; Shalabi, Nabeel; Martin, Eden R; Margolis, Todd P; Sarantopoulos, Constantine D; Levitt, Roy C
2015-08-01
To evaluate the relationship between dry eye symptoms, non-ocular conditions and tear film parameters. Cross-sectional study. The study population consisted of patients who were seen in the Miami Veterans Affairs eye clinic. Patients filled out standardised questionnaires assessing dry eye symptoms (dry eye questionnaire 5 (DEQ5) and ocular surface disease index (OSDI)), non-ocular pain, depression and post-traumatic stress disorder (PTSD), and also underwent measurement of tear film parameters. Correlations between dry eye symptoms and non-ocular conditions as compared with tear film parameters. 136 patients with a mean age of 65 (SD 11) years participated in the study. All correlations between the dry eye questionnaire scores (DEQ5 and OSDI) and (A) self-reported non-ocular pain measures (numerical rating scale and pain history), (B) depression and (C) PTSD were significant and moderate in strength (Pearson's coefficient 0.24 to 0.60, p<0.01 for all). All correlations between the dry eye questionnaires and tear film measures were weak (Pearson's coefficient -0.10 to 0.18) and most were not significant. Multivariable linear regression analyses revealed that PTSD and non-ocular pain more closely associated with dry eye symptoms than did tear film parameters. Specifically, non-ocular pain and PTSD accounted for approximately 36% of the variability in DEQ5 scores (R=0.60) and approximately 40% of variability in OSDI scores (R=0.64). Of note, none of the tear parameters remained significantly associated with dry eye symptoms in either model. Dry eye symptoms more closely align to non-ocular pain, depression and PTSD than to tear film parameters. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Bae, Kyu Hwan; Kim, Jeong Woo; Kim, Tae Kyun; Kweon, Seok Hyun; Kang, Hong Je; Kim, Jong Yun; Joo, Min Su; Kim, Dong Moon
2016-09-01
We aimed to identify the clinical and structural outcomes after arthroscopic repair of full-thickness rotator cuff tears of all sizes with a modified tension band suture technique. Among 63 patients who underwent arthroscopic rotator cuff repair for a full-thickness rotator cuff tear with the modified tension band suture technique at a single hospital between July 2011 and March 2013, 47 were enrolled in this study. The mean follow-up period was 29 months. Visual analog scale scores, range of motion, American Shoulder and Elbow Surgeons scores, Constant scores, and Shoulder Strength Index were measured preoperatively and at the final follow-up. For radiologic evaluation, we conducted magnetic resonance imaging 6 months postoperatively and ultrasonography at the final follow-up. We allocated the small and medium tears to group A and the large and massive tears to group B and then compared clinical outcomes and repair integrity. Postoperative clinical outcomes at the final follow-up showed significant improvements compared with those seen during preoperative evaluations (P < .001). However, group B showed worse clinical results than group A. Evaluation with magnetic resonance imaging performed 6 months postoperatively and ultrasonography taken at the final follow-up revealed that group B showed a significantly higher retear rate than did group A (69% vs. 6%, respectively; P < .001). Arthroscopic repair with the modified tension band suture technique for rotator cuff tears was a more suitable method for small to medium tears than for large to massive tears. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Graphene-silicone elastomer nanocomposite
NASA Astrophysics Data System (ADS)
Pan, Shuyang
The incorporation of fillers to improve the Young's modulus, tensile strength, and elongation at failure of polymeric matrices is ubiquitous. While Young's modulus and tensile strength of the matrix increase with the filler concentration, a threshold filler concentration must be achieved for the elongation at failure to increase. Furthermore, a decrease in elongation at failure has also been observed beyond a critical filler concentration. While the increases in modulus and tensile strength have been attributed to the transfer of mechanical load to the stronger filler, the onset and reversal in elongation at failure are not understood. In this thesis, we use a functionalized graphene sheet (FGS) -- silicone elastomer (SE) nanocomposite as a model system to demonstrate the mechanisms responsible for this observed filler concentration-dependant elongation at failure as well its subsequent reversal. We will also demonstrate the mechanisms that create the continual increase in tensile strength as filler concentration increases. As the lateral size of FGS strongly influences the tensile strength of the resulting composite, in the first part of this thesis, we show that the oxidation path and the mechanical energy input influence the size of graphene oxide sheets derived from graphite oxide. The cross-planar oxidation of graphite from the (0002) plane results in periodic cracking of the uppermost graphene oxide layer, limiting its lateral dimension to less than 30 microm. We use an energy balance between the elastic strain energy associated with the undulation of graphene oxide sheets at the hydroxyl and epoxy sites, the crack formation energy, and the interaction energy between graphene layers to determine the cell size of the cracks. Under both edge-to-center and cross-planar oxidations, the size of graphene oxide sheets is determined by the aspect ratio of graphite and the mechanical energy input in processing the sheets. In the second part of this thesis, we use atomic force microscopy-based single molecule force spectroscopy and infrared spectroscopy to show that the FGS-SE interface is dominated by the hydrogen bonds between the hydroxyl and epoxy groups on FGS and polydimethylsiloxane (PDMS, uncrosslinked form of SE) monomers. These hydrogen bonds allow the mechanical load to be transferred from the weaker SE to the stronger FGS, leading to an improvement in the tensile strength of SE. The strength of a single PDMS-FGS hydrogen bond is measured to be 30-120 pN and it is on the same order of magnitude as the strengths of other types of hydrogen bonds previously reported. In the final part of the thesis, utilizing experimental analysis and a two dimensional viscoelastic lattice model constructed by our collaborators, we show that while load transfer to FGS is the main cause of the enhancements in modulus and strength, the enhancement in elongation at failure is due to FGS-induced distributed tearing. First critical concentration, which defines the mechanical percolation, corresponds to the isolation of tensile zones generated by the fillers, as well as the initiation of tear arresting and deflection, thus enhancing distributed tearing and deformation. At the second critical concentration, cumulative dilation caused by distributed tearing reaches a maximum, leading to the reversal in elongation in failure.
Tetteh, Sophia; Bibb, Richard J; Martin, Simon J
2018-05-30
The objective of this study was to determine the effect of plant based antimicrobial solutions specifically tea tree and Manuka oil on facial silicone elastomers. The purpose of this in vitro study was to evaluate the effect of disinfection with plant extract solution on mechanical properties and morphology on the silicone elastomer. Test specimens were subjected to disinfection using tea tree oil, Manuka oil and the staphylococcus epidermidis bacteria. Furthermore, a procedure duration was used in the disinfection process to simulate up to one year of usage. Over 500 test specimens were fabricated for all tests performed namely hardness, elongation, tensile, tear strength tests, visual inspection and lastly surface characterization using SEM. A repeated measures ANOVA revealed that hardness and elongation at break varied significantly over the time period, whereas this was not observed in the tear and tensile strength parameters of the test samples.
Farr, Sebastian; Zechmann, Ulrike; Ganger, Rudolf; Girsch, Werner
2015-08-01
The purpose of this study was to report our preliminary results after arthroscopically-assisted repair of peripheral triangular fibrocartilage complex (TFCC) tears in adolescent patients. All children and adolescents who underwent arthroscopically-assisted repair of a Palmer 1B tear were identified and prospectively evaluated after a mean follow-up of 1.3 years. The postoperative assessment included documentation of clinical parameters, pain score (visual analogue scale, VAS), grip strength and completion of validated outcome scores (Modified Mayo Wrist Score, MMWS; Disabilities of the Arm, Shoulder and Hand Inventory, DASH). A total of 12 patients (four males, eight females) with a mean age of 16.3 years at the time of surgery were evaluated. The mean VAS decreased significantly from 7.0 to 1.7 after the procedure. We observed a significant increase of the MMWS after surgery; however, MMWS was still significantly lower at final follow-up when compared to the contralateral side. A mean postoperative DASH score of 16 indicated an excellent outcome after the procedure. DASH Sports and Work Modules showed fair and good overall outcomes in the short-term, respectively. Grip strength averaged 86 % of the contralateral side at final follow-up, with no significant difference being found between both sides. Arthroscopically-assisted repair of peripheral TFCC tears in adolescents provided predictable pain relief and markedly improved functional outcome scores. Concomitant pathologies may have to be addressed at the same time to eventually achieve a satisfactory outcome. Sports participation, however, may be compromised in the short-term and should therefore be resumed six months postoperatively.
Dynamic thoracohumeral kinematics are dependent upon the etiology of the shoulder injury.
López-Pascual, Juan; Page, Álvaro; Serra-Añó, Pilar
2017-01-01
Obtaining kinematic patterns that depend on the shoulder injury may be important when planning rehabilitation. The main goal of this study is to explore whether the kinematic patterns of continuous and repetitive shoulder elevation motions are different according to the type of shoulder injury in question, specifically tendinopathy or rotator cuff tear, and to analyze the influence of the load handled during its assessment. For this purpose, 19 individuals with tendinopathy and 9 with rotator cuff tear performed a repetitive scaption movement that was assessed with stereophotogrammetry. Furthermore, static range of motion (ROM) and isometric strength were evaluated with a goniometer and a dynamometer, respectively. Dynamic measurements of maximum elevation (Emax), variablility of the maximum angle (VMA), maximum angular velocity (Velmax), and time to maximum velocity (tmaxvel) were found to be significantly different between the tendinopathy group (TG) and the rotator cuff tear group (RTCG). No differences were found in the ROM assessed with goniometry and the isometric strength. The effect of increasing the load placed in the hand during the scaption movement led to significant differences in Emax, VMA, tmaxvel and repeatability. Therefore, only the dynamic variables showed sufficient capability of detecting differences in functional performance associated with structural shoulder injury. The differences observed in the kinematic variables between patients with tendinopathy and rotator cuff tear seem to be related to alterations in thoracohumeral rhythm and neuromuscular control. Kinematic analysis may contribute to a better understanding of the functional impact of shoulder injuries, which would help in the assessment and treatment of shoulder pain.
Dynamic thoracohumeral kinematics are dependent upon the etiology of the shoulder injury
López-Pascual, Juan; Page, Álvaro; Serra-Añó, Pilar
2017-01-01
Obtaining kinematic patterns that depend on the shoulder injury may be important when planning rehabilitation. The main goal of this study is to explore whether the kinematic patterns of continuous and repetitive shoulder elevation motions are different according to the type of shoulder injury in question, specifically tendinopathy or rotator cuff tear, and to analyze the influence of the load handled during its assessment. For this purpose, 19 individuals with tendinopathy and 9 with rotator cuff tear performed a repetitive scaption movement that was assessed with stereophotogrammetry. Furthermore, static range of motion (ROM) and isometric strength were evaluated with a goniometer and a dynamometer, respectively. Dynamic measurements of maximum elevation (Emax), variablility of the maximum angle (VMA), maximum angular velocity (Velmax), and time to maximum velocity (tmaxvel) were found to be significantly different between the tendinopathy group (TG) and the rotator cuff tear group (RTCG). No differences were found in the ROM assessed with goniometry and the isometric strength. The effect of increasing the load placed in the hand during the scaption movement led to significant differences in Emax, VMA, tmaxvel and repeatability. Therefore, only the dynamic variables showed sufficient capability of detecting differences in functional performance associated with structural shoulder injury. The differences observed in the kinematic variables between patients with tendinopathy and rotator cuff tear seem to be related to alterations in thoracohumeral rhythm and neuromuscular control. Kinematic analysis may contribute to a better understanding of the functional impact of shoulder injuries, which would help in the assessment and treatment of shoulder pain. PMID:28841697
Single-Versus Double-Row Arthroscopic Rotator Cuff Repair in Massive Tears
Wang, EnZhi; Wang, Liang; Gao, Peng; Li, ZhongJi; Zhou, Xiao; Wang, SongGang
2015-01-01
Background It is a challenge for orthopaedic surgeons to treat massive rotator cuff tears. The optimal management of massive rotator cuff tears remains controversial. Therefore, the goal of this study was to compare arthroscopic single- versus double-row rotator cuff repair with a larger sample size. Material/Methods Of the subjects with massive rotator cuff tears, 146 were treated using single-row repair, and 102 were treated using double-row repair. Pre- and postoperative functional outcomes and radiographic images were collected. The clinical outcomes were evaluated for a minimum of 2 years. Results No significant differences were shown between the groups in terms of functional outcomes. Regarding the integrity of the tendon, a lower rate of post-treatment retear was observed in patients who underwent double-row repair compared with single-row repair. Conclusions The results suggest that double-row repair is relatively superior in shoulder ROM and the strength of tendon compared with single-row repair. Future studies involving more patients in better-designed randomized controlled trials will be required. PMID:26017641
Botulinum toxin is detrimental to repair of a chronic rotator cuff tear in a rabbit model.
Gilotra, Mohit; Nguyen, Thao; Christian, Matthew; Davis, Derik; Henn, R Frank; Hasan, Syed Ashfaq
2015-08-01
Re-tear continues to be a problem after rotator cuff repair. Intramuscular botulinum toxin (Botox) injection can help optimize tension at the repair site to promote healing but could have an adverse effect on the degenerated muscle in a chronic tear. We hypothesized that Botox injection would improve repair characteristics without adverse effect on the muscle in a chronic rotator cuff tear model. The supraspinatus tendon of both shoulders in 14 rabbits underwent delayed repair 12 weeks after transection. One shoulder was treated with intramuscular Botox injection and the other with a saline control injection. Six weeks after repair, outcomes were based on biomechanics, histology, and magnetic resonance imaging. Botox-treated repairs were significantly weaker (2.64 N) than control repairs (5.51 N, p = 0.03). Eighty percent of Botox-treated repairs and 40% of control repairs healed with some partial defect. Fatty infiltration of the supraspinatus was present in all shoulders (Goutallier Grade 3 or 4) but was increased in the setting of Botox. This study provides additional support for the rabbit supraspinatus model of chronic cuff tear, showing consistent fatty infiltration. Contrary to our hypothesis, Botox had a negative effect on repair strength and might increase fatty infiltration. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Möbius, R; Schleifenbaum, S; Grunert, R; Löffler, S; Werner, M; Prietzel, T; Hammer, N
2016-10-01
The removal of well-fixed acetabular components following THA (total hip arthroplasty) is a difficult operation and could be accompanied by the loss of acetabular bone stock. The optimal method for fixation is still under debate. The aim of this pilot study was to compare the tear-out resistance and failure behavior between osseo-integrated and non-integrated screw cups. Furthermore, we examined whether there are differences in the properties mentioned between screw sockets and cemented polyethylene cups. Tear-out resistance and related mechanical work required for the tear-out of osseo-integrated screw sockets are higher than in non-integrated screw sockets. Ten human coxal bones from six cadavers with osseo-integrated screw sockets (n=4), non-integrated (implanted post-mortem, n=3) screw sockets and cemented polyethylene cups (n=3) were used for tear-out testing. The parameters axial failure load and mechanical work for tear-out were introduced as measures for determining the stability of acetabular components following THA. The osseo-integrated screw sockets yielded slightly higher tear-out resistance (1.61±0.26kN) and related mechanical work compared to the non-integrated screw sockets (1.23±0.39kN, P=0.4). The cemented polyethylene cups yielded the lowest tear-out resistance with a failure load of 1.18±0.24kN. Compared to the screw cups implanted while alive, they also differ on a non-significant level (P=0.1). Osseous failure patterns differed especially for the screw sockets compared to the cemented polyethylene cups. Osseo-integration did not greatly influence the tear-out stability in cementless screw sockets following axial loading. Furthermore, the strength of the bone-implant-interface of cementless screw sockets appears to be similar to cemented polyethylene cups. However, given the high failure load, high mechanical load and because of the related bone failure patterns, removal should not be performed by means of tear-out but rather by osteotomes or other curved cutting devices to preserve the acetabular bone stock. Level III, case-control-study. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Steinhaus, Michael E; Makhni, Eric C; Lieber, Adam C; Kahlenberg, Cynthia A; Gulotta, Lawrence V; Romeo, Anthony A; Verma, Nikhil N
2016-11-01
Outcomes assessments after superior labrum anterior and posterior (SLAP) tear/repair are highly varied, making it difficult to draw comparisons across the literature. This study examined the inconsistency in outcomes reporting in the SLAP tear literature. We hypothesize that there is significant variability in outcomes reporting and that although most studies may report return to play, time to return reporting will be highly variable. The PubMed, Medline, Scopus, and Embase databases were systematically reviewed for studies from January 2000 to December 2014 reporting outcomes after SLAP tear/repair. Two reviewers assessed each study, and those meeting inclusion criteria were examined for pertinent data. Outcomes included objective (range of motion, strength, clinical examinations, and imaging) and subjective (patient-reported outcomes, satisfaction, activities of daily living, and return to play) measures. Of the 56 included studies, 43% documented range of motion, 14% reported strength, and 16% noted postoperative imaging. There was significant variation in use of patient-reported outcomes measures, with the 3 most commonly noted measures reported in 20% to 55% of studies. Return to play was noted in 75% of studies, and 23% reported time to return, with greater rates in elite athletes. Eleven studies (20%) did not report follow-up or noted data with <12 months of follow-up. The SLAP literature is characterized by substantial variability in outcomes reporting, with time to return to play noted in few studies. Efforts to standardize outcomes reporting would facilitate comparisons across the literature and improve our understanding of the prognosis of this injury. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Partial supraspinatus tears are associated with tendon lengthening.
Farshad-Amacker, Nadja A; Buck, Florian M; Farshad, Mazda; Pfirrmann, Christian W A; Gerber, Christian
2015-02-01
Tendon tear may result in muscular retraction with the loss of contractile amplitude and strength of the rotator cuff muscles. Currently, neither a validated method of measuring supraspinatus tendon length nor normal values are known. It was therefore the purpose of this study to measure the normal length of the supraspinatus tendon and to determine whether partial tears are associated with changes in tendon length. MR examinations of 49 asymptomatic volunteers and 37 patients with arthroscopically proven, isolated partial tears of the supraspinatus tendon were compared. The ratio of the extramuscular tendon length to the distance between the footprint and the glenoid surface was calculated (TL/FG ratio). Tendon length measurements were taken by two independent readers at the bursal and articular surfaces at the anterior, the central and the posterior parts of the tendon. TL/FG ratios at the bursal surface of tendons with partial tears were significantly higher than those in the control group [anterior: 0.78 ± 0.20 vs. 0.66 ± 0.15 (p < 0.05); central: 0.61 ± 0.13 vs. 0.52 ± 0.10 (p < 0.05); posterior: 0.57 ± 0.15 vs. 0.52 ± 0.10 (p < 0.05)]. At the articular surface, differences were significant only anteriorly [0.60 ± 0.13, vs. 0.54 ± 0.10 (p < 0.05)]. A cut-off TL/FG ratio of 0.63 for measurements at the bursal surface in the center of the tendon achieved a sensitivity of 46 % and a specificity of 92 % for the identification of partial cuff tearing. A reproducible method for measurement of extramuscular supraspinatus tendon length is described. Partial tearing of the supraspinatus tendon is associated with significant tendon lengthening, suggesting failure in continuity, and this is most reliably measured on the bursal surface. III.
Geven, Mike A; Barbieri, Davide; Yuan, Huipin; de Bruijn, Joost D; Grijpma, Dirk W
2015-01-01
Composite materials of photo-crosslinked poly(trimethylene carbonate) and nanoscale hydroxyapatite were prepared and their mechanical characteristics for application as orbital floor implants were assessed. The composites were prepared by solvent casting poly(trimethylene carbonate) macromers with varying amounts of nano-hydroxyapatite and subsequent photo-crosslinking. The incorporation of the nano-hydroxyapatite into the composites was examined by thermogravimetric analysis, scanning electron microscopy and gel content measurements. The mechanical properties were investigated by tensile testing and trouser tearing experiments. Our results show that nano-hydroxyapatite particles can readily be incorporated into photo-crosslinked poly(trimethylene carbonate) networks. Compared to the networks without nano-hydroxyapatite, incorporation of 36.3 wt.% of the apatite resulted in an increase of the E modulus, yield strength and tensile strength from 2.2 MPa to 51 MPa, 0.5 to 1.4 N/mm2 and from 1.3 to 3.9 N/mm2, respectively. We found that composites containing 12.4 wt.% nano-hydroxyapatite had the highest values of strain at break, toughness and average tear propagation strength (376% , 777 N/mm2 and 3.1 N/mm2, respectively).
Bovine versus Porcine Acellular Dermal Matrix: A Comparison of Mechanical Properties.
Adelman, David M; Selber, Jesse C; Butler, Charles E
2014-05-01
Porcine and bovine acellular dermal matrices (PADM and BADM, respectively) are the most commonly used biologic meshes for ventral hernia repair. A previous study suggests a higher rate of intraoperative device failures using PADM than BADM. We hypothesize that this difference is, in part, related to intrinsic mechanical properties of the matrix substrate and source material. The following study directly compares these 2 matrices to identify any potential differences in mechanical properties that may relate to clinical outcomes. Sections of PADM (Strattice; Lifecell, Branchburg, N.J.) and BADM (SurgiMend; TEI Biosciences, Boston, Mass.) were subjected to a series of biomechanical tests, including suture retention, tear strength, and uniaxial tensile strength. Results were collected and compared statistically. In all parameters, BADM exhibited a superior mechanical strength profile compared with PADM of similar thickness. Increased BADM thickness correlated with increased mechanical strength. In suture tear-through testing with steel wire, failure of the steel wire occurred in the 4-mm-thick BADM, whereas the matrix material failed in all other thicknesses of BADM and PADM. Before implantation, BADM is inherently stronger than PADM at equivalent thicknesses and considerably stronger at increased thicknesses. These results corroborate clinical data from a previous study in which PADM was associated with a higher intraoperative device failure rate. Although numerous properties of acellular dermal matrix contribute to clinical outcomes, surgeons should consider initial mechanical strength properties when choosing acellular dermal matrices for load-bearing applications such as hernia repair.
Linear growth rates of resistive tearing modes with sub-Alfvénic streaming flow
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, L. N.; College of Sciences, China Jiliang University, Hangzhou 310018; Ma, Z. W., E-mail: zwma@zju.edu.cn
2014-07-15
The tearing instability with sub-Alfvénic streaming flow along the external magnetic field is investigated using resistive MHD simulation. It is found that the growth rate of the tearing mode instability is larger than that without the streaming flow. With the streaming flow, there exist two Alfvén resonance layers near the central current sheet. The larger perturbation of the magnetic field in two closer Alfvén resonance layers could lead to formation of the observed cone structure and can largely enhance the development of the tearing mode for a narrower streaming flow. For a broader streaming flow, a larger separation of Alfvénmore » resonance layers reduces the magnetic reconnection. The linear growth rate decreases with increase of the streaming flow thickness. The growth rate of the tearing instability also depends on the plasma beta (β). When the streaming flow is embedded in the current sheet, the growth rate increases with β if β < β{sub s}, but decreases if β > β{sub s}. The existence of the specific value β{sub s} can be attributed to competition between the suppressing effect of β and the enhancing effect of the streaming flow on the magnetic reconnection. The critical value β{sub s} increases with increase of the streaming flow strength.« less
Agrawal, Vivek
2012-01-01
Purpose: This study presents a retrospective case series of the clinical and structural outcomes (1.5 T MRI) of arthroscopic rotator cuff repair with acellular human dermal graft reinforcement performed by a single surgeon in patients with large, massive, and previously repaired rotator cuff tears. Materials and Methods: Fourteen patients with mean anterior to posterior tear size 3.87 ± 0.99 cm (median 4 cm, range 2.5–6 cm) were enrolled in the study and were evaluated for structural integrity using a high-field (1.5 T) MRI at an average of 16.8 months after surgery. The Constant-Murley scores, the Flexilevel Scale of Shoulder Function (Flex SF), scapular plane abduction, and strength were analyzed. Results: MRI results showed that the rotator cuff repair was intact in 85.7% (12/14) of the patients studied. Two patients had a Sugaya Type IV recurrent tear (2 of 14; 14.3%), which were both less than 1 cm. The Constant score increased from a preoperative mean of 49.72 (range 13–74) to a postoperative mean of 81.07 (range 45–92) (P value = 0.009). Flexilevel Scale of Shoulder Function (Flex SF) Score normalized to a 100-point scale improved from a preoperative mean of 53.69 to a postoperative mean of 79.71 (P value = 0.003). The Pain Score improved from a preoperative mean of 7.73 to a postoperative mean of 13.57 (P value = 0.008). Scapular plane abduction improved from a preoperative mean of 113.64° to a postoperative mean of 166.43° (P value = 0.010). The strength subset score improved from a preoperative mean of 1.73 kg to a postoperative mean of 7.52 kg (P value = 0.006). Conclusions: This study presents a safe and effective technique that may help improve the healing rates of large, massive, and revision rotator cuff tears with the use of an acellular human dermal allograft. This technique demonstrated favorable structural healing rates and statistically improved functional outcomes in the near term. Level of Evidence: 4. Retrospective case series. PMID:22787332
Development of low viscosity alkane-based urethane for connector potting applications
NASA Technical Reports Server (NTRS)
Morris, D. E.
1983-01-01
Two series of saturated hydrocarbon-based urethanes were prepared with isophorone diisocyanate and one series with methyl bis (4-cyclohexyl isocyanate). The urethanes with molecular weights as great as 2500 had viscosities low enough and a working life long enough to be used in potting, molding, and coating applications. Specimens were prepared and mechanical properties such as hardness, tensile strength elongation, and tear strength were determined. Thermomechanical properties (glass transition and expansion coefficient) and thermogravimetric properties were determined.
Crack Growth Simulation and Residual Strength Prediction in Airplane Fuselages
NASA Technical Reports Server (NTRS)
Chen, Chuin-Shan; Wawrzynek, Paul A.; Ingraffea, Anthony R.
1999-01-01
The objectives were to create a capability to simulate curvilinear crack growth and ductile tearing in aircraft fuselages subjected to widespread fatigue damage and to validate with tests. Analysis methodology and software program (FRANC3D/STAGS) developed herein allows engineers to maintain aging aircraft economically, while insuring continuous airworthiness, and to design more damage-tolerant aircraft for the next generation. Simulations of crack growth in fuselages were described. The crack tip opening angle (CTOA) fracture criterion, obtained from laboratory tests, was used to predict fracture behavior of fuselage panel tests. Geometrically nonlinear, elastic-plastic, thin shell finite element crack growth analyses were conducted. Comparisons of stress distributions, multiple stable crack growth history, and residual strength between measured and predicted results were made to assess the validity of the methodology. Incorporation of residual plastic deformations and tear strap failure was essential for accurate residual strength predictions. Issue related to predicting crack trajectory in fuselages were also discussed. A directional criterion, including T-stress and fracture toughness orthotropy, was developed. Curvilinear crack growth was simulated in coupon and fuselage panel tests. Both T-stress and fracture toughness orthotropy were essential to predict the observed crack paths. Flapping of fuselages were predicted. Measured and predicted results agreed reasonable well.
Autologous tenocyte implantation into shoulder tendon pathology in an elite swimmer.
Schwab, Laura M; Blanch, Peter; Young, Mark
2018-01-01
The use of novel bioengineer treatment techniques such as Autologous Tenocyte Implantation (ATI) have shown promising improvements in both pain ratings and functional outcomes in elbow, gluteal and shoulder tendon pathology. This case will review the injury timeline of ATI intervention in an elite male swimmer with subscapularis tendon pathology and investigate whether ATI has a concomitant healing effect associated with improved functional outcomes. A palmaris longus tendon biopsy was performed and cells were expanded by in-vitro culture. Autologous tenocytes were injected into the subscapularis site identified. Three blinded radiologists reported on pre and post shoulder MRIs using the same 3T MRI protocol. A validated rating scale for severity of tendinopathy (0-3) and degree of tear (0-3) was used and hand-held Dynamometry (HHD) strength was recorded. Independent blinded radiology review demonstrated a significant reduction in tear size and improved tendon morphology. IR strength on HHD returned to baseline strength levels post ATI (231-253N) 6 weeks post intervention. The athlete returned to full training (volume and intensity) pain free and international level competition at 4 months post ATI. An athlete who had previously undergone unsuccessful conservative management demonstrated significant improvement in function and in tendon morphology post intervention. Copyright © 2017 Elsevier Ltd. All rights reserved.
Pillukat, T; Fuhrmann, R A; Windolf, J; van Schoonhoven, J
2016-08-01
Refixation of the triangular fibrocartilage complex (TFCC) to the ulnar capsule of the wrist. Distal TFCC tears without instability, proximal TFCC intact. Loose ulnar TFCC attachment without tear or instability. Peripheral TFCC tears with instability of the distal radioulnar joint (DRUJ). Complex or proximal tears of the TFCC. Isolated, central degenerative tears without healing potential. Arthroscopically guided, minimally invasive suture of the TFCC to the base of the sixth extensor compartment. Above elbow plaster splint, 70° flexion of the elbow joint, 45° supination for 6 weeks. Skin suture removal after 2 weeks. No physiotherapy to extend pronation and supination during the first 3 months. In an ongoing long-term study, 7 of 31 patients who underwent transcapsular refixation of the TFCC between 1 January 2003 and 31 December 2010 were evaluated after an average follow-up interval of 116 ± 34 months (range 68-152 months). All patients demonstrated an almost nearly unrestricted range of wrist motion and grip strength compared to the unaffected side. All distal radioulnar joints were stable. On the visual analogue scale (VAS 0-10), pain at rest was 1 ± 1 (range 0-2) and pain during exercise 2 ± 2 (range 0-5); the DASH score averaged 10 ± 14 points (range 0-39 points). All patients were satisfied. The modified Mayo wrist score showed four excellent, two good, and one fair result. These results correspond to the results of other series. Transcapsular refixation is a reliable, technically simple procedure in cases with ulnar-sided TFCC tears without instability leading to good results.
Highway pavement performance test for colored thin anti-skidding layers
NASA Astrophysics Data System (ADS)
Gao, Wei; Cui, Wei; Xu, Ming
2018-03-01
Based on the actual service condition of highway pavement colored thin anti-skidding layers, with materials of color quartz sand and two-component acrylic resin as basis, we designed such tests as the bond strength, shearing strength, tear strength, fatigue performance and aggregate polished value, and included the freeze-thaw cycle and de-icing salt and other factors in the experiment, connecting with the climate characteristics of circumpolar latitude and low altitude in Heilongjiang province. Through the pavement performance test, it is confirmed that the colored thin anti-skidding layers can adapt to cold and humid climate conditions, and its physical mechanical properties are good.
Ide, Junji; Karasugi, Tatsuki; Okamoto, Nobukazu; Taniwaki, Takuya; Oka, Kiyoshi; Mizuta, Hiroshi
2015-10-01
We compared the outcomes of knotless double-row suture bridge and single-row repairs in patients undergoing arthroscopic repair for anterosuperior rotator cuff tears. We included 61 full-thickness anterosuperior rotator cuff tears treated by arthroscopic repair, namely, single-row repair (group 1: 25 shoulders; mean patient age, 64 years) and the knotless double-row suture bridge repair (group 2: 36 shoulders; mean patient age, 62 years). Preoperative and postoperative magnetic resonance imaging was performed for all shoulders. Clinical outcomes were evaluated for mean follow-up periods of 81 months (range, 72-96 months) in group 1 and 34 months (range, 24-42 months) in group 2, using the University of California, Los Angeles and Japanese Orthopaedic Association assessments. At the final follow-up, both groups showed improvement in the average University of California, Los Angeles and Japanese Orthopaedic Association scores and range of motion, although no intergroup differences were observed. Both groups showed improved abduction strength, and the average score was higher in group 2 (P = .0112). The lift-off and belly-press test results were improved in both groups. Postoperatively, the incidence of positive lift-off tests tended to be lower (P = .075) and that of positive belly-press tests was lower in group 2, P = .049). The repair failure rate tended to be lower in group 2 (14% [5 of 36]) than in group 1 (32% [8 of 25]; P = .0839). Arthroscopic knotless double-row suture bridge repair of anterosuperior rotator cuff tears yielded functional outcomes equivalent to those of single-row repair and may be useful for improving subscapularis function, abduction strength, and tendon healing. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Le Huec, J C; Liquois, F; Schaeverbecke, T; Zipoli, B; Chauveaux, D; Le Rebeller, A
1996-01-01
We report a series of 14 patients with a massive rotator cuff tear operated on with a deltoid flap according to Augereau's technique. The aim of this study was to evaluate the benefits of this technique using Constant's scoring system. The follow up is 40 months. 14 patients, mean age 59 years, with a total rotator cuff tear type III according to Gerber's classification were included. There was 13 total ruptures of the supra and infra spinatus tendon and one infraspinatus and subscapularis lesion. All the patients had shoulder pain, and the preoperative, Constant's score was 24.1/100. The diagnosis of the rotator cuff rupture was confirmed by X-rays, arthrography and ultra-sonography. 8 patients had a Magnetic Resonance Imaging (MRI) evaluation. The surgical procedure was the technique described by Augereau, and three patients had a resection of the distal clavicle. One patient had a small piece of dacron to reinforce the suture of a very thin deltoid flap. All the patients had a immobilization in abduction and the rehabilitation programm began immediately. Results on pain were good: +11.4 points according to Constant's score, but improvement strength (+0.7 point) or motion (+1 point) was not significative. Postoperative Constant's score was 46.9, ponderated score increased from 29.5 per cent to 57.5 per cent. Ten patients were very satisfied, 2 were satisfied and two were disappointed. One of them neaded shoulder arthrodesis; the other needed a new surgery to remove the piece of dacron, and was allayed with NSAI drugs. External rotation was slightly increased: +2 point. These results are similar to others series on pain relief, but the results are poor on strength restauration and on shoulder motion. This technique is a heavy surgical procedure and results are not better than arthroscopic sub acromial decompression for massive rotator cuff tear.
Park, Gayoung; Kim, Yun Hee; Kim, Dong Soo; Ko, Young Chun
2010-05-01
Morphology and vulcanizate properties of EPDM/SBR blends were investigated. AAHR (a mixture of aliphatic and aromatic hydrocarbon resins) was used as a compatibilizer and bis(3-triethoxysilylpropyl)tetrasulfide (TESPT) was used as a coupling agent. The vulcanizate properties and the morphological studies revealed that EPDM and SBR were incompatible, and the addition of AAHR was very effective to enhance the compatibility between EPDM and SBR. The weight percent of bound rubbers was increased with increasing SBR contents. The addition of an AAHR increased the amounts of bound rubbers, and hence the vulcanizate properties such as tear strength and fatigue resistance of the EPDM/SBR blends were improved. The dynamic mechanical analysis and the morphological studies revealed that the addition of TESPT increased the weight of bound rubbers and provided better dispersion of carbon black, resulting in good mechanical properties such as tear strength and fatigue resistance of the vulcanized EPDM/SBR blends. The smaller particle of zinc oxide (i.e., 50 nm > 100 nm > 1000 nm) yielded to the better blending properties of the polymer blend.
On the strength of random fiber networks
NASA Astrophysics Data System (ADS)
Deogekar, S.; Picu, R. C.
2018-07-01
Damage accumulation and failure in random fiber networks is of importance in a variety of applications, from design of synthetic materials, such as paper and non-wovens, to accidental tearing of biological tissues. In this work we study these processes using three-dimensional models of athermal fiber networks, focusing attention on the modes of failure and on the relationship between network strength and network structural parameters. We consider network failure at small and large strains associated with the rupture of inter-fiber bonds. It is observed that the strength increases linearly with the network volume fraction and with the bond strength, while the stretch at peak stress is inversely related to these two parameters. A small fraction of the bonds rupture before peak stress and this fraction increases with increasing failure stretch. Rendering the bond strength stochastic causes a reduction of the network strength. However, heterogeneity retards damage localization and increases the stretch at peak stress, therefore promoting ductility.
Rotator cuff tears: An evidence based approach
Sambandam, Senthil Nathan; Khanna, Vishesh; Gul, Arif; Mounasamy, Varatharaj
2015-01-01
Lesions of the rotator cuff (RC) are a common occurrence affecting millions of people across all parts of the globe. RC tears are also rampantly prevalent with an age-dependent increase in numbers. Other associated factors include a history of trauma, limb dominance, contralateral shoulder, smoking-status, hypercholesterolemia, posture and occupational dispositions. The challenge lies in early diagnosis since a high proportion of patients are asymptomatic. Pain and decreasing shoulder power and function should alert the heedful practitioner in recognizing promptly the onset or aggravation of existing RC tears. Partial-thickness tears (PTT) can be bursal-sided or articular-sided tears. Over the course of time, PTT enlarge and propagate into full-thickness tears (FTT) and develop distinct chronic pathological changes due to muscle retraction, fatty infiltration and muscle atrophy. These lead to a reduction in tendon elasticity and viability. Eventually, the glenohumeral joint experiences a series of degenerative alterations - cuff tear arthropathy. To avert this, a vigilant clinician must utilize and corroborate clinical skill and radiological findings to identify tear progression. Modern radio-diagnostic means of ultrasonography and magnetic resonance imaging provide excellent visualization of structural details and are crucial in determining further course of action for these patients. Physical therapy along with activity modifications, anti-inflammatory and analgesic medications form the pillars of nonoperative treatment. Elderly patients with minimal functional demands can be managed conservatively and reassessed at frequent intervals. Regular monitoring helps in isolating patients who require surgical interventions. Early surgery should be considered in younger, active and symptomatic, healthy patients. In addition to being cost-effective, this helps in providing a functional shoulder with a stable cuff. An easily reproducible technique of maximal strength and sturdiness should by chosen among the armamentarium of the shoulder surgeon. Grade 1 PTTs do well with debridement while more severe lesions mandate repair either by trans-tendon technique or repair following conversion into FTT. Early repair of repairable FTT can avoid appearance and progression of disability and weakness. The choice of surgery varies from surgeon-to-surgeon with arthroscopy taking the lead in the current scenario. The double-row repairs have an edge over the single-row technique in some patients especially those with massive tears. Stronger, cost-effective and improved functional scores can be obtained by the former. Both early and delayed postoperative rehabilitation programmes have led to comparable outcomes. Guarded results may be anticipated in patients in extremes of age, presence of comorbidities and severe tear patters. Overall, satisfactory results are obtained with timely diagnosis and execution of the appropriate treatment modality. PMID:26716086
The effect of configuration on strength, durability, and handle of Kevlar fabric-based materials
NASA Technical Reports Server (NTRS)
Reuter, L. L.; Munson, J. B.
1977-01-01
Five Kevlar based laminates and three Kevlar based coated materials were designed, hand made, and tested against comparative conventional Dacron based materials for strength, peel, tear, puncture, creases, and handle. Emphasis was placed on evaluating geometric orientation of constituents, use of elastomeric film in place of high modulus films, and the use of flying thread loom bias reinforcement of Kevlar yarns. Whereas, the performance of the Kevlar laminates was severely degraded by crease effects, significant gains in overall performance factors were shown for the coated Kevlar materials.
The Frictional Force with Respect to the Actual Contact Surface
NASA Technical Reports Server (NTRS)
Holm, Ragnar
1944-01-01
Hardy's statement that the frictional force is largely adhesion, and to a lesser extent, deformation energy is proved by a simple experiment. The actual contact surface of sliding contacts and hence the friction per unit of contact surface was determined in several cases. It was found for contacts in normal atmosphere to be about one-third t-one-half as high as the macroscopic tearing strength of the softest contact link, while contacts annealed in vacuum and then tested, disclosed frictional forces which are greater than the macroscopic strength.
Hamano, Noritaka; Yamamoto, Atsushi; Shitara, Hitoshi; Ichinose, Tsuyoshi; Shimoyama, Daisuke; Sasaki, Tsuyoshi; Kobayashi, Tsutomu; Kakuta, Yohei; Osawa, Toshihisa; Takagishi, Kenji
2017-06-01
Muscle atrophy and fatty infiltration in the rotator cuff muscles are often observed in patients with chronic rotator cuff tears. The recovery from these conditions has not been clarified. Ninety-four patients were included in this study. The improvement in muscle atrophy and fatty infiltration in successfully repaired rotator cuff tears was evaluated by magnetic resonance imaging at 1 year and 2 years after surgery and was compared with muscle atrophy and fatty infiltration observed on magnetic resonance imaging at 2 weeks after surgery to discount any changes due to the medial retraction of the torn tendon. The patients' muscle strength was evaluated in abduction and external rotation. Muscle atrophy and fatty infiltration of the supraspinatus were significantly improved at 2 years after surgery in comparison to 2 weeks after surgery. The subjects' abduction and external rotation strength was also significantly improved at 2 years after surgery in comparison to the preoperative values. Patients whose occupation ratio was improved had a better abduction range of motion, stronger abduction strength, and higher Constant score. Patients whose fatty infiltration was improved had a better range of motion in flexion and abduction, whereas the improvements of muscle strength and the Constant score were similar in the group that showed an improvement of fatty infiltration and the group that did not. Muscle atrophy and fatty infiltration can improve after rotator cuff repair. The strengths of abduction and external rotation were also improved at 2 years after surgery. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Mechanical & morphological properties of attapulgite/NR composites: Effect of mixing time variation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nor, Nor Aina Mohd, E-mail: ayena90@yahoo.com; Othman, Nadras, E-mail: srnadras@usm.my; Ismail, Hanafi, E-mail: ihanafi@usm.my
2015-07-22
The development of composite material based on attapulgite clay (ATP) as a filler and natural rubber (NR) matrices were prepared by combination of melt mixing and latex compounding methods. Sonication technique was chosen in this work to disperse the attapulgite suspension. 6 phr of attapulgite loading was fabricated using different time of mixing ranging from 30 minutes until 2 hours and sonication time was kept constant at 15 minutes. Then, co-coagulating HA latex with attapulgite clay suspension through latex compounding method produced the masterbatch. The masterbatch was compounded with natural rubber by melt mixing method. The mechanical and morphological characteristicsmore » were investigated in this work. From mechanical testing, M1 showed the highest value of tensile and tear strength. By comparing with M30 and M2, M1 shows high 300% tensile modulus and lower crosslink density. However, when the time of mixing was prolonged to 2 hours, the results for tensile strength, elongation at break and tear strength were decreased. This is due to flocculation of attapulgite particles. Sonication techniques also proved that the tensile strength and elongation at break of these three samples were higher compared to gum NR (NR) and attapulgite compounded with NR using a conventional method (in-situ 6). From field emission scanning electron microscope (FESEM) results, it revealed that M1 had good dispersion in the NR system. It is proved that the higher tensile strength was due to good dispersion of attapulgite clay in the NR matrix. It was also supported from crosslink density, which is lower than NR and in-situ 6 results. It showed that the penetration of toluene solvent into rubber compound was restricted. The optimum time, M1 give the best results, which can be compared to control the sample.« less
A fracture criterion for widespread cracking in thin-sheet aluminum alloys
NASA Technical Reports Server (NTRS)
Newman, J. C., Jr.; Dawicke, D. S.; Sutton, M. A.; Bigelow, C. A.
1993-01-01
An elastic-plastic finite-element analysis was used with a critical crack-tip-opening angle (CTOA) fracture criterion to model stable crack growth in thin-sheet 2024-T3 aluminum alloy panels with single and multiple-site damage (MSD) cracks. Comparisons were made between critical angles determined from the analyses and those measured with photographic methods. Calculated load against crack extension and load against crack-tip displacement on single crack specimens agreed well with test data even for large-scale plastic deformations. The analyses were also able to predict the stable tearing behavior of large lead cracks in the presence of stably tearing MSD cracks. Small MSD cracks significantly reduced the residual strength for large lead cracks.
Clinical guidelines for management of dry eye associated with Sjögren disease.
Foulks, Gary N; Forstot, S Lance; Donshik, Peter C; Forstot, Joseph Z; Goldstein, Michael H; Lemp, Michael A; Nelson, J Daniel; Nichols, Kelly K; Pflugfelder, Stephen C; Tanzer, Jason M; Asbell, Penny; Hammitt, Katherine; Jacobs, Deborah S
2015-04-01
To provide a consensus clinical guideline for management of dry eye disease associated with Sjögren disease by evaluating published treatments and recommending management options. Consensus panel evaluation of reported treatments for dry eye disease. Using the 2007 Report of the International Workshop on Dry Eye (DEWS) as a starting point, a panel of eye care providers and consultants evaluated peer-reviewed publications and developed recommendations for evaluation and management of dry eye disease associated with Sjögren disease. Publications were graded according to the American Academy of Ophthalmology Preferred Practice Pattern guidelines for level of evidence. Strength of recommendation was according to the Grading of Recommendations Assessment, Development and Evaluation (GRADE) guidelines. The recommendations of the panel are briefly summarized herein. Evaluation should include symptoms of both discomfort and visual disturbance as well as determination of the relative contribution of aqueous production deficiency and evaporative loss of tear volume. Objective parameters of tear film stability, tear osmolarity, degree of lid margin disease, and ocular surface damage should be used to stage severity of dry eye disease to assist in selecting appropriate treatment options. Patient education with regard to the nature of the problem, aggravating factors, and goals of treatment is critical to successful management. Tear supplementation and stabilization, control of inflammation of the lacrimal glands and ocular surface, and possible stimulation of tear production are treatment options that are used according to the character and severity of dry eye disease. Management guidelines for dry eye associated with Sjögren's disease are presented. Copyright © 2015 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Supkis, D. E.
1975-01-01
Selected fire-retardant materials for possible application to commercial aircraft are described. The results of flammability screening tests and information on the physical and chemical properties of both original and newly installed materials after extended use are presented in tabular form, with emphasis on wear properties, strength, puncture and tear resistances, and cleanability.
Mechanical Testing of Common-Use Polymeric Materials with an In-House-Built Apparatus
ERIC Educational Resources Information Center
Pedrosa, Cristiana; Mendes, Joaquim; Magalhaes, Fernao D.
2006-01-01
A low-cost tensile testing machine was built for testing polymeric films. This apparatus also allows for tear-strength and flexural tests. The experimental results, obtained from common-use materials, selected by the students, such as plastic bags, illustrate important aspects of the mechanical behavior of polymeric materials. Some of the tests…
Galanopoulos, Ilias; Ilias, Aslanidis; Karliaftis, Konstantinos; Papadopoulos, Dimitrios; Ashwood, Neil
2017-01-01
Background: It is generally accepted that rotator cuff repair gives satisfactory results in the long term, although most studies have so far shown a fairly high rate of structural failure or re-tear. The purpose of this review study is to assess whether failure of the repaired cuff to heal could negatively affect the functional outcome. Methods: This article includes an extensive Internet PubMed based research in the current English-language literature including level I to level V studies as well as systematic reviews. Results: According to this extended study research, the results are mixed; certain reports show that patients with a healed rotator cuff repair have improved function and strength compared to those with structural failure, whereas other studies support the generally perceived concept that tendon re-tear does not lead to inferior clinical outcome. Conclusion: Further high-level prospective studies with larger numbers of patients and longer follow up are needed to overcome the current debate over function between healed and failed rotator cuff repairs. PMID:28400878
Influence of asymmetric magnetic perturbation on the nonlinear evolution of double tearing modes
NASA Astrophysics Data System (ADS)
Xiong, G. Z.; Wang, L.; Li, X. Q.; Liu, H. F.; Tang, C. J.; Huang, J.; Zhang, X.; Wang, X. Q.
2017-06-01
The effects of asymmetric magnetic perturbation on the triggering and evolution of double tearing modes (DTMs) are investigated using nonlinear magnetohydrodynamics simulations in a slab geometry. We find that for reversed magnetic shear plasmas the resistive reconnection process induced by the initial perturbation at one rational surface can drive a new island at the other rational surface with the same mode number. The four typical states of the mode for the time evolution are found, and include: (i) a linear growth stage; (ii) a linear/nonlinear stable stage; (iii) an interactively driving stage; and (iv) a symmetric DTM stage. These differ from previous simulation results. Moreover, nonlinear DTM growth is found to strongly depend on the asymmetric magnetic perturbation, particularly in the early nonlinear phase. The initial perturbation strength scale of island width suggests that the left island enters into a Sweet-Parker growth process when the right island is sufficiently large to effectively drive the other. These results predict that although externally applied magnetic perturbations can suppress the neoclassical tearing mode they can also trigger new instabilities such as asymmetric DTMs.
Grueninger, Patrick; Nikolic, Nikola; Schneider, Joerg; Lattmann, Thomas; Platz, Andreas; Chmiel, Corinne; Meier, Christoph
2015-11-01
To prospectively assess arthroscopic repair of massive cuff tears (MCT) in a highly selective patient group with large subscapularis (SSC) tendon tears by means of clinical results and magnetic resonance imaging (MRI) studies. Between April 2009 and December 2010, 26 patients with MCT were treated with arthroscopic rotator cuff repair. Only lesions involving a large tear of the SSC tendon (Lafosse III or IV) in combination with a complete tear of the supraspinatus (SSP) tendon and a tear of at least the anterior third of the infraspinatus (ISP) tendon were included. Minimum follow-up was 1 year. Pre- and postoperative assessment included a standardized clinical examination, subjective patient outcome, and MRI (structural integrity, fatty muscle infiltration, and muscular mass). Mean follow-up was 17 months (range, 12 to 34 months). MRI was performed in 25 patients. In 21 (84%) the cuff repair was intact. A partial retear of the SSC was found in 2 patients (8%). In 2 patients (8%) a full-thickness retear of the posterosuperior cuff was observed (1 SSP, 1 SSP/ISP). A significant increase of the muscle mass and decrease of fatty infiltration was observed for the SSC and SSP but not for the ISP. The mean Constant-Murley score improved from 36 to 86 points (P < .001) with all its subscores as well (P < .001). Muscular strength improved for the SSC (4.9 v 3.0, P < .001), SSP (4.6 v 2.9, P < .001), and ISP (4.8 v 3.4, P < .001). Overall patient satisfaction was high (3.6 ± 0.8). Arthroscopic repair of MCT involving the ISP, SSP, and large tears of the SSC provides a reliable tendon healing, in particular for the SSC tendon, combined with good functional results. Level IV, therapeutic case series. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Gwark, Ji-Yong; Sung, Chang-Meen; Na, Jae-Boem; Park, Hyung Bin
2018-05-19
To compare the structural and clinical outcomes after arthroscopic rotator cuff repair (ARCR) of a case group aged 70 and above with those of a control group younger than 70, with the 2 groups matched for sex and tear size. The case group, comprising 53 patients 70 or older, and the control group, comprising 159 patients younger than 70, all received ARCR to 1 shoulder with symptomatic full-thickness rotator cuff tear. The case and the control subjects, who were matched for sex and tear size to minimize bias related to tendon healing, received ARCR during the same period. The mean age was 71.8 ± 2.6 years in the case group and 59.3 ± 7.1 years in the control group. The minimum follow-up period was 1 year in both groups. Cuff integrity was evaluated using ultrasonography. Structural and clinical outcomes of the 2 groups were compared. Regarding structural outcomes, the complete healing, partial-thickness retear, and full-thickness retear rates were 66% (35/53), 15% (8/53), and 19% (10/53) in the case group, and 68% (108/159), 19% (30/159), and 13% (21/159), respectively, in the control group. The 2 groups had no significantly different retear rates (P = .52). Regarding clinical outcomes, the mean improvements in range of motion, pain, muscle strength, and age- and sex-matched Constant scores were not significantly different between the 2 groups (P > .37). The preoperative tear size was significantly associated with retear in both studied groups (P = .02). The clinical and structural outcomes of ARCR in patients 70 or older with symptomatic full-thickness rotator cuff tear are comparable with those in patients younger than 70 with at least 1-year follow-up. Preoperative tear size, a biological factor, is a strong predictor for retear. Level III, a retrospective comparative (case-control) study. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Outcome of Lateral Transfer of the FHL or FDL for Concomitant Peroneal Tendon Tears.
Seybold, Jeffrey D; Campbell, John T; Jeng, Clifford L; Short, Kelly W; Myerson, Mark S
2016-06-01
Concomitant tears of the peroneus longus and brevis tendons are rare injuries, with literature limited to case reports and small patient series. Only 1 recent study directly compared the results of single-stage lateral deep flexor transfer, and no previous series objectively evaluated power and balance following transfer. The purpose of this study was to evaluate clinical outcomes, patient satisfaction, and objective power and balance data following single-stage flexor hallucis longus (FHL) and flexor digitorum longus (FDL) tendon transfers for treatment of concomitant peroneus longus and brevis tears. Over an 8-year period (2005-2012), 9 patients underwent lateral transfer of the FHL or FDL tendon for treatment of concomitant peroneus longus and brevis tears. All but 1 patient underwent additional procedures to address hindfoot malalignment or other contributing deformity at the time of surgery. Mean age was 56.9 years, and average body mass index was 27.9. Lateral transfer of the FHL was performed in 5 patients, and FDL transfer performed in 4 with mean follow-up 35.7 months (range: 11-94). Eight of 9 patients completed SF-12 and Foot Function Index (FFI) scores, and 7 returned for range of motion (ROM) and manual strength testing of the involved and normal extremities. These 7 patients also completed force plate balance tests, in addition to peak force and power testing on a PrimusRS machine with a certified physical therapist. All patients were satisfied with the results of the procedure. Mean SF-12 physical and mental scores were 32 and 55, respectively; mean FFI total score was 56.7. No postoperative infections were noted. Two patients continued to utilize orthotics or braces, and 2 patients reported occasional pain with weightbearing activity. Three patients noted mild paresthesias in the distribution of the sural nerve and 2 demonstrated tibial neuritis. All patients demonstrated 4/5 eversion strength in the involved extremity. Average loss of inversion and eversion ROM were 24.7% and 27.2% of normal, respectively. Mean postoperative eversion peak force and power were decreased greater than 55% relative to the normal extremity. Patients demonstrated nearly 50% increases in both center-of-pressure tracing length and velocity during balance testing. There were no statistically significant differences between the FHL and FDL transfer groups with regards to clinical examination or objective power and balance tests. The FHL and FDL tendons were both successful options for lateral transfer in cases of concomitant peroneus longus and brevis tears. Objective measurements of strength and balance demonstrated significant deficits in the operative extremity, even years following the procedure. These differences, however, did not appear to alter or inhibit patient activity levels or high satisfaction rates with the procedure. Although anatomic studies have demonstrated benefits of FHL transfer over the FDL tendon, further studies with increased patient numbers are needed to determine if these differences are clinically significant. Level IV, retrospective case series. © The Author(s) 2016.
Drainage and fractionation of wood fibers in a flotation froth
J.Y. Zhu; Freya Tan
2005-01-01
Understanding fiber fractionation in a froth is very important to the quality of recovered fibers in flotation deinking operations. Fiber length is a very important fiber quality parameter in paper-making. For example, long fibers tend to produce a paper with higher tear strength than short fibers. In this study, fibers in froth collected at different froth drainage...
James S. Han; Thomas A. Rymsza
1999-01-01
Chemical pulping of kenaf fiber is comparatively new. In this study, bast, core, and whole stalk kenaf fibers were pulped using a soda-AQ pulping process and various pulping conditions. Handsheets were evaluated for density, Canadian standard freeness, brightness, opacity, smoothness, and tensile, burst, and tear indexes and strength. The results indicate that...
NASA Astrophysics Data System (ADS)
Zhao, Xiaoye; Tan, Caiwang; Meng, Shenghao; Chen, Bo; Song, Xiaoguo; Li, Liqun; Feng, Jicai
2018-03-01
Fiber laser welding-brazing of 1-mm-thick AZ31B Mg alloys to 1.5-mm-thick copper (T2) with Mg-based filler was performed in a lap configuration. The weld appearance, interfacial microstructure and mechanical properties were investigated with different heat inputs. The results indicated that processing windows for optimizing appropriate welding parameters were relatively narrow in this case. Visually acceptable joints with certain strength were achieved at appropriate welding parameters. The maximum tensile-shear fracture load of laser-welded-brazed Mg/Cu joint could reach 1730 N at the laser power of 1200 W, representing 64.1% joint efficiency relative to AZ31Mg base metal. The eutectic structure (α-Mg + Mg2Cu) and Mg-Cu intermetallic compound was observed at the Mg/Cu interface, and Mg-Al-Cu ternary intermetallic compound were identified between intermetallics and eutectic structure at high heat input. All the joints fractured at the Mg-Cu interface. However, the fracture mode was found to differ. For laser power of 1200 W, the surface was characterized by tearing edge, while that with poor joint strength was almost dominated by smooth surface or flat tear pattern.
Research into topology optimization and the FDM method for a space cracked membrane
NASA Astrophysics Data System (ADS)
Hu, Qingxi; Li, Wanyuan; Zhang, Haiguang; Liu, Dali; Peng, Fujun; Duan, Yongchao
2017-07-01
The problem that the space membranes are easily torn open is the main focus in this paper, and a bionic strengthening-ribs structure is proposed for a space membrane based on interdisciplinary strengths, such as topology optimization, composite materials, and rapid prototyping. The optimization method and modeling method of membranes with bionic strengthening-ribs was studied. The PEEK and SCF/PEEK composite material which are applied to the space environment are chosen, and FDM technology is used. Through topology optimization, bionic strengthening-ribs with good tensile and tear capacities were obtained. Cracked membranes, cracked membranes with PEEK strengthening-ribs and SCF/PEEK strengthening-ribs were tested and test data were obtained. An extension situation and tension fracture were compared for three cases. The experimental results showed that membranes with the bionic strengthening-ribs structure have better mechanical properties, and the strength of the membranes with PEEK and SCF/PEEK strengthening-ribs were raised, respectively, up to 266.9% and 185.9%. The strengthening-ribs structure greatly improves the capacity to halt membrane crack-growth, which has an important significance to avoid membrane tear, and to ensure the spacecraft orbital lifetime.
Weldability evaluation of high tensile plates using GMAW process
NASA Astrophysics Data System (ADS)
Datta, R.; Mukerjee, D.; Rohira, K. L.; Veeraraghavan, R.
1999-08-01
High tensile plates, SAILMA-450 high impact (HI) (yield strength, 45 kg/mm2 minimum; ultimate tensile strength, 57 kg/mm2 minimum; elongation, 19% minimum; Charpy impact energy 2.0 kg.m at -20 °C minimum) were successfully developed at the Steel Authority of India Ltd., up to 32 mm plate thickness. Since then the steel has been extensively used for the fabrication of impellers, bridges, excavators, and mining machineries, where welding is an important processing step. The present study deals with the weldability properties of SAILMA-450 HI plates employing the gas metal arc welding process and carbon dioxide gas. Implant and elastic restraint cracking tests were conducted to assess the cold cracking resistance of the weld joint under different welding conditions. The static fatigue limit values were found to be in excess of minimum specified yield strength at higher heat input levels (9.4 and 13.0 kJ/cm), indicating adequate cold cracking resistance. The critical restraint intensities, K cr, were found to vary between 720 and 1280 kg/mm2, indicating that the process can be utilized for fabrication of structures involving moderate to low restraint intensities (200 to 1000 kg/mm2). Lamellar tear tests conducted using full thickness plates at heat input levels ranging from 10 to 27 kJ/cm showed no incidence of lamellar tear upon visual, ultrasonic, and four-section macroexamination. These tests were repeated using machined plates, such that the midthickness of the plates (segregated zone) corresponded to the heat affected zone of the weld. No cracks were observed, indicating good lamellar tear resistance of the weld joint. Optimized welding conditions were formulated based on these tests. The weld joint was subjected to extensive tests to assess the physical properties and soundness of the weld joint. The weld joint exhibited good strength (64.7 kg/mm2) and impact toughness (5.7 and 3.5 kg.m at -20 °C for weld metal and heat affected zone properties. Crack tip opening displacement (CTOD) tests carried out for parent metal, heat-affected zone, and weld metal resulted in δm values of 0.41, 0.40, and 0.34 mm, respectively, which indicates adequate resistance to cleavage fracture. It was concluded that the weld joint conforms to the requirements of SAILMA-450 HI specification and ensures a high integrity of the fabricated products.
Cryogenic mechanical properties of low density superplastically formable Al-Li alloys
NASA Technical Reports Server (NTRS)
Verzasconi, S. L.; Morris, J. W., Jr.
1989-01-01
The aerospace industry is considering the use of low density, superplastically formable (SPF) materials, such as Al-Li alloys in cryogenic tankage. SPF modifications of alloys 8090, 2090, and 2090+In were tested for strength and Kahn tear toughness. The results were compared to those of similar tests of 2219-T87, an alloy currently used in cryogenic tankage, and 2090-T81, a recently studied Al-Li alloy with exceptional cryogenic properties (1-9). With decreasing temperature, all materials showed an increase in strength, while most materials showed an increase in elongation and decrease in Kahn toughness. The indium addition to 2090 increased alloy strength, but did not improve the strength-toughness combination. The fracture mode was predominantly intergranular along small, recrystallized grains, with some transgranular fracture, some ductile rupture, and some delamination on large, unrecrystallized grains.
Sousa, Paul L; Krych, Aaron J; Cates, Robert A; Levy, Bruce A; Stuart, Michael J; Dahm, Diane L
2017-05-01
The purpose of this study was to determine whether patients with excellent 6-month functional testing after ACL reconstruction had (1) higher risk of subsequent ACL tears, (2) superior knee function, and (3) increased activity levels compared to those with delayed clearance for return to sports at midterm follow-up. A total of 223 patients underwent primary ACL reconstruction by a single surgeon and had functional and isokinetic testing performed 6 months post-operatively between 1998 and 2005. Of the 223 patients, 52 (23 %) made the excellent group and were allowed return to sport at 6 months, and the remaining 171 (77 %) constituted the delayed group. Rate of ACL graft tear and native contralateral ACL tear was compared between groups. In addition, IKDC and Tegner scores were compared at a mean 4-year follow-up. The graft rupture rate was similar in the excellent group (3.8 %, n = 2) compared to the delayed group (4.7 %, n = 8; p = 0.30). However, there was a higher rate of contralateral ACL tear in the excellent group (15.4 %, n = 8 vs. 5.3 %, n = 9; p = 0.003). The excellent 6-month group had superior IKDC scores (94.3 ± 6.4 vs. 90.9 ± 9.7; p = 0.04) and Tegner scores (6.6 ± 1.8 vs. 5.7 ± 1.6; p = 0.01). Patients with an excellent performance on their isokinetic strength and functional testing at 6 months after ACL reconstruction have superior knee function and higher activity levels at midterm follow-up. However, these patients appear to be at greater risk of contralateral ACL injury, which may be related to their increased activity level. When isokinetic and functional testing is used for return-to-sport decisions, physicians should caution patients about the risk of contralateral ACL injury for high performing patients. Retrospective Review with Control, Level III.
Creation of second order magnetic barrier inside chaos created by NTMs in the ASDEX UG
NASA Astrophysics Data System (ADS)
Ali, Halima; Punjabi, Alkesh
2012-10-01
Understanding and stabilization of neoclassical tearing modes (NTM) in tokamaks is an important problem. For low temperature plasmas, tearing modes are believed to be mainly driven by current density gradient. For collisionless plasmas, even when plasma is stable to classical tearing modes, helical reduction in bootstrap current in O-point of an island can destabilize NTMs when an initial island is seeded by other global MHD instabilities or when microturbulence triggers the transition from a linear to nonlinear instability. The onset of NTMs leads to the most serious beta limit in ASDEX UG tokamak [O. Gubner et al 2005 NF 39 1321]. The important NTMs in the ASDDEX UG are (m,n)=(3,2)+(4,3)+(1,1). Realistic parameterization of these NTMs and the safety factor in ASDEX UG are given in [O. Dumbrajs et al 2005 POP 12 1107004]. We use a symplectic map in magnetic coordinates for the ASDEX UG to integrate field lines in presence of the NTMs. We add a second order control term [H. Ali and A. Punjabi 2007 PPCF 49 1565] to this ASDEX UG field line Hamiltonian to create an invariant magnetic surface inside the chaos generated by the NTMs. The relative strength, robustness, and resilience of this barrier are studied to ascertain the most desirable noble barrier in the ASDEX UG with NTMs. We present preliminary results of this work, and discuss its implications with regard to magnetic transport barriers for increasing strength of magnetic perturbations. This work is supported by the grants DE-FG02-01ER54624 and DE-FG02-04ER54793.
High melt strength, tear resistant blown film based on poly(lactic acid)
NASA Astrophysics Data System (ADS)
Edmonds, Neil R.; Plimmer, Peter N.; Tanner, Chris
2015-05-01
A major problem associated with the commercial manufacture of thin films from PLA is inferior processing characteristics on blown film lines compared to low density polyethylene. PLA has poor melt strength (leading to bubble instability) and develops a permanent crease in the flattened film as it exits the tower of the film line. In addition, the thin film product has poor tear strength and an unacceptable `noise' level when converted into flexible packaging. Furthermore, fabricated articles based on PLA are known to show an unattractive tendency toward dimensional instability. This behaviour is associated with `cold crystallization', a phenomenon which also causes exudation of any plasticizer added for improving flexibility. Blow moulded articles based on PLA also exhibit dimensional sensitivity above 60°C. All of these issues have been overcome by the technology described in this paper. This has been accomplished without loss of the valuable compostability characteristic of PLA; this was confirmed by evaluation of film in a commercial composting operation. These results have been achieved through novel reactive compounding technology which: (a) Creates a PLA-rich structure containing long chain crosslinks, (b) generates a low glass transition temperature phase covalently bonded to the PLA structure, and (c) provides a material which performs like LDPE in a blown film manufacturing operation. The technology developed is covered by NZ Patent 580231 (3). The patent is held by UniServices Ltd, The University of Auckland, New Zealand.
Apinhasmit, Wandee; Limsombutanon, Somchai; Swasdison, Somporn; Suppipat, Nophadol
2003-10-01
Dental rubber dams (RDs) were used as barrier membranes in guided tissue regeneration for the treatment of periodontal intraosseous defects with acceptable clinical results. The aim of the present study was to investigate the effects of autoclave sterilization on properties of RD as related to its use as a barrier membrane in guided tissue regeneration. RDs were sterilized by either an autoclave, gamma irradiation, or chemical agents and then co-cultured with human gingival fibroblasts. The cell responses to sterilized RDs were investigated by inverted phase contrast microscopy, scanning electron microscopy (SEM) and 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT) technique. The surface alterations of the autoclaved RDs were observed under SEM. The tensile strength, tear strength and elongation at break of the autoclaved RDs were tested by a universal testing machine. The results from cell culture, microscopic and MTT studies showed that RDs sterilized by autoclave and gamma irradiation did not deteriorate gingival fibroblasts and provided surfaces suitable for cell attachment, whereas chemical-sterilized RDs were toxic to these cells. Ultrastructurally, surface changes from the non-autoclaved RDs, including some melted areas, small pores and folds were observed on the autoclaved RD surface. The tensile strength and tear strength of the autoclaved RDs were significantly lower than those of the non-autoclaved RDs (p = 0.042, p < 0.001, respectively). In contrast, the elongation at break of the autoclaved RDs was higher than that of the non-autoclaved RDs (p < 0.001). These results suggest that the autoclave sterilization deteriorated the physical properties of RDs even though they seemed to be compatible to the cultured human cells. Therefore, the sterilization method should be taken into consideration when RDs are utilized as barrier membranes.
Zhang, Zhenxiang; Gu, Beibei; Zhu, Wei; Zhu, Lixian; Li, Qingsong
2014-08-01
This prospective, randomized study was performed to evaluate the results of mini-open and arthroscopic rotator cuff repair in a comparative case series of patients followed for 24 months. A total of 125 patients were randomized to mini-open (Group I) or arthroscopic (Group II) rotator cuff repair at the time of surgical intervention. The University of California Los Angeles (UCLA) score, the American Shoulder and Elbow Surgeons (ASES) index, and muscle strength were measured to evaluate the clinical results, while magnetic resonance arthrography was used at 24-month follow-up to investigate the postoperative rotator cuff integrity. Fifty-three patients in Group I and 55 patients in Group II were available for evaluation at 24-month follow-up. At 24-month follow-up, the UCLA score, the ASES index, and muscle strength were statistically significantly increased in both groups postoperatively, while no significant difference was detected between the 2 groups. Intact rotator cuffs were investigated in 42 patients in Group I and 35 in Group II, and there was a significant difference in postoperative structural integrity between the two groups (P < 0.05). When analysis was limited to the patients with full-thickness tear, the muscle strength of the shoulder was significantly better in Group II, and the retearing rate was significantly higher in Group II. Based on the results obtained from this study, it can be indicated that arthroscopic and mini-open rotator cuff repair displayed substantially equal outcomes, except for higher retearing rate in the arthroscopic repair group. While for patients with full-thickness tear, arthroscopic rotator cuff repair displayed better shoulder strength and significantly higher retearing rate as compared to mini-open rotator cuff repair at 24-month follow-up.
Self-assembly of graphene ribbons by spontaneous self-tearing and peeling from a substrate
NASA Astrophysics Data System (ADS)
Annett, James; Cross, Graham L. W.
2016-07-01
Graphene and related two-dimensional materials have shown unusual and exceptional mechanical properties, with similarities to origami-like paper folding and kirigami-like cutting demonstrated. For paper analogues, a critical difference between macroscopic sheets and a two-dimensional solid is the molecular scale of the thin dimension of the latter, allowing the thermal activation of considerable out-of-plane motion. So far thermal activity has been shown to produce local wrinkles in a free graphene sheet that help in theoretically understanding its stability, for example, and give rise to unexpected long-range bending stiffness. Here we show that thermal activation can have a more marked effect on the behaviour of two-dimensional solids, leading to spontaneous and self-driven sliding, tearing and peeling from a substrate on scales approaching the macroscopic. We demonstrate that scalable nanoimprint-style contact techniques can nucleate and direct the parallel self-assembly of graphene ribbons of controlled shape in ambient conditions. We interpret our observations through a simple fracture-mechanics model that shows how thermodynamic forces drive the formation of the graphene-graphene interface in lieu of substrate contact with sufficient strength to peel and tear multilayer graphene sheets. Our results show how weak physical surface forces can be harnessed and focused by simple folded configurations of graphene to tear the strongest covalent bond. This effect may hold promise for the patterning and mechanical actuating of devices based on two-dimensional materials.
Arroyo-Hernández, M; Mellado-Romero, M A; Páramo-Díaz, P; Martín-López, C M; Cano-Egea, J M; Vilá Y Rico, J
2015-01-01
The purpose of this study is to analyze if there is any difference between the arthroscopic reparation of full-thickness supraspinatus tears with simple row technique versus suture bridge technique. We accomplished a retrospective study of 123 patients with full-thickness supraspinatus tears between January 2009 and January 2013 in our hospital. There were 60 simple row reparations, and 63 suture bridge ones. The mean age in the simple row group was 62.9, and in the suture bridge group was 63.3 years old. There were more women than men in both groups (67%). All patients were studied using the Constant test. The mean Constant test in the suture bridge group was 76.7, and in the simple row group was 72.4. We have also accomplished a statistical analysis of each Constant item. Strength was higher in the suture bridge group, with a significant statistical difference (p 0.04). The range of movement was also greater in the suture bridge group, but was not statistically significant. Suture bridge technique has better clinical results than single row reparations, but the difference is not statistically significant (p = 0.298).
Charles W. McMillin
1968-01-01
Specific refining energy and gross wood properties accounted for as much as 90% of the total variation in strength of handsheets made from 96 pulps disk-refined from chips of varying characteristics. Burst, tear, and breaking length were increased by applying high specific refining energy and using fast-grown wood of high latewood content but of relatively low density...
Contribution of Hydrogen Bonds to Paper Strength Properties.
Przybysz, Piotr; Dubowik, Marcin; Kucner, Marta Anna; Przybysz, Kazimierz; Przybysz Buzała, Kamila
2016-01-01
The objective of this work was to investigate the influence of hydrogen bonds between fibres on static and dynamic strength properties of paper. A commercial bleached pinewood kraft pulp was soaked in water, refined in a PFI, and used to form paper webs in different solvents, such as water, methanol, ethanol, n-propanol and n-butanol, to determine the effect of their dipole moment on static and dynamic strength properties of resulting paper sheets. Paper which was formed in water, being the solvent of the highest dipole moment among the tested ones, showed the highest breaking length and tear resistance. When paper webs were formed in n-butanol, which was the least polar among the solvents, these parameters were reduced by around 75%. These results provide evidence of the importance of water in paper web formation and strong impact of hydrogen bonds between fibres on strength properties of paper.
Contribution of Hydrogen Bonds to Paper Strength Properties
Przybysz, Piotr; Dubowik, Marcin; Kucner, Marta Anna; Przybysz, Kazimierz; Przybysz Buzała, Kamila
2016-01-01
The objective of this work was to investigate the influence of hydrogen bonds between fibres on static and dynamic strength properties of paper. A commercial bleached pinewood kraft pulp was soaked in water, refined in a PFI, and used to form paper webs in different solvents, such as water, methanol, ethanol, n-propanol and n-butanol, to determine the effect of their dipole moment on static and dynamic strength properties of resulting paper sheets. Paper which was formed in water, being the solvent of the highest dipole moment among the tested ones, showed the highest breaking length and tear resistance. When paper webs were formed in n-butanol, which was the least polar among the solvents, these parameters were reduced by around 75%. These results provide evidence of the importance of water in paper web formation and strong impact of hydrogen bonds between fibres on strength properties of paper. PMID:27228172
Bond strengths evaluation of laser ceramic bracket debonding
NASA Astrophysics Data System (ADS)
Dostalová, T.; Jelinková, H.; Šulc, J.; Němec, M.; Fibrich, M.; Jelínek, M.; Michalík, P.; Bučková, M.
2012-09-01
Ceramic brackets often used for an orthodontic treatment can lead to problems such as enamel tear outs because of their low fracture resistance and high bond strengths. Therefore the aim of our study was to investigate the positive laser radiation effect on bracket debonding. Moreover, the influence of the enamel shape surface under the bracket and laser radiation power on the debonding strength was investigated. The source of the radiation was the longitudinally diode-pumped Tm:YAP laser operating at 1997 nm. To eliminate the tooth surface roughness the flat enamel surface was prepared artificially and the bracket was bonded on it. The debonding was accomplished by Tm:YAP laser radiation with different the power value while recording the temperature rise in the pulp. To simulate the debonding process in vivo the actual bond strength was measured by the digital force gauge. The results were analyzed by scanning electron microscope.
NASA Astrophysics Data System (ADS)
B. G. Porto, Karina Meschini; Napolitano, Celia Marina; Borrely, Sueli Ivone
2018-01-01
The integrity of materials containing packaging (natural or synthetic polymers) is essential to keep the aseptic condition of commercialized products (health care products, food and pharmaceuticals). The objective of this paper was to study gamma radiation effects (25 kGy, 40 kGy and 50 kGy) on the main properties of paper and multilayer films (polyester and polyethylene). Paper and multilayer films are components of packaging (pouches) for radiation sterilization containing medical equipment or products. Paper was the more radiation sensitive among the studied materials and radiation effects were more pronounced at brightness, pH, tearing resistance, bursting strength and tensile strength. Concerning plastic film, no pinholes were induced by radiation and the effects on the tensile strength were not significant. Although the seal strength packaging (pouches) decreased according to increasing dose, the sealing integrity was preserved.
Nelson, Cory O; Sileo, Michael J; Grossman, Mark G; Serra-Hsu, Frederick
2008-08-01
The purpose of this study was to compare the time-zero biomechanical strength and the surface area of repair between a single-row modified Mason-Allen rotator cuff repair and a double-row arthroscopic repair. Six matched pairs of sheep infraspinatus tendons were repaired by both techniques. Pressure-sensitive film was used to measure the surface area of repair for each configuration. Specimens were biomechanically tested with cyclic loading from 20 N to 30 N for 20 cycles and were loaded to failure at a rate of 1 mm/s. Failure was defined at 5 mm of gap formation. Double-row suture anchor fixation restored a mean surface area of 258.23 +/- 69.7 mm(2) versus 148.08 +/- 75.5 mm(2) for single-row fixation, a 74% increase (P = .025). Both repairs had statistically similar time-zero biomechanics. There was no statistical difference in peak-to-peak displacement or elongation during cyclic loading. Single-row fixation showed a higher mean load to failure (110.26 +/- 26.4 N) than double-row fixation (108.93 +/- 21.8 N). This was not statistically significant (P = .932). All specimens failed at the suture-tendon interface. Double-row suture anchor fixation restores a greater percentage of the anatomic footprint when compared with a single-row Mason-Allen technique. The time-zero biomechanical strength was not significantly different between the 2 study groups. This study suggests that the 2 factors are independent of each other. Surface area and biomechanical strength of fixation are 2 independent factors in the outcome of rotator cuff repair. Maximizing both factors may increase the likelihood of complete tendon-bone healing and ultimately improve clinical outcomes. For smaller tears, a single-row modified Mason-Allen suture technique may provide sufficient strength, but for large amenable tears, a double row can provide both strength and increased surface area for healing.
Formulation/cure technology for ultrahigh molecular weight silphenylene-siloxane polymers
NASA Technical Reports Server (NTRS)
Hundley, N. H.; Patterson, W. J.
1985-01-01
Molecular weights above one million were achieved for methylvinylsilphenylene-siloxane terpolymers using a two-stage polymerization technique which was successfully scaled up to 200 grams. The resulting polymer was vulcanized by two different formulations and compared to an identically formulated commercial methylvinyl silicone on the basis of ultimate strength, Young's modulus, percent elongation at failure, and tear strength. Relative thermal/oxidative stabilities of the elastomers were assessed by gradient and isothermal thermogravimetric analyses performed in both air and nitrogen. The experimental elastomer exhibited enhanced thermal/oxidative stability and possed equivalent or superior mechanical properties. The effect of variations in prepolymer molecular weight on mechanical properties was also investigated.
Cheon, Sang-Jin; Kim, Jung-Han; Gwak, Heui-Chul; Kim, Chang-Wan; Kim, Jeon-Kyo; Park, Ji-Hwan
2017-05-01
The purpose of this study was to compare histologic healing and biomechanical characteristics between 2 repair techniques (layer by layer, repair of each layer to bone separately; and whole layer, repair of each layer to the bone en masse) for delaminated rotator cuff tear. Rabbits were used as subjects and classified into 2 groups: group A, right side, the layer-by-layer repair group; and group B, left side, the whole-layer repair group. Histologic evaluations were done at 3 weeks (n = 7) and 6 weeks (n = 4) after operation. Biomechanical tests to evaluate the tensile property were done at time 0 (n = 5) and 3 weeks (n = 5) after operation. Histologic healing improved in all groups. A smaller cleft was found between layers in group B compared with the cleft in group A at 3 weeks after operation. At time 0, group A showed a higher yield load and ultimate failure load (67 ± 10.5 N and 80 ± 7.8 N, respectively). However, at 3 weeks after operation, group B showed a higher yield load (48 ± 7.6 N). In the delaminated rotator cuff tear model in the rabbit, the whole-layer repair showed a narrow gap between layers and a higher yield load at 3 weeks after operation. Surgical techniques that unite the cleft in a delaminated tear could improve biomechanical strength after operation. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Platelet rich plasma in arthroscopic rotator cuff repair: a prospective RCT study, 2-year follow-up.
Randelli, Pietro; Arrigoni, Paolo; Ragone, Vincenza; Aliprandi, Alberto; Cabitza, Paolo
2011-06-01
Local application of autologous platelet rich plasma (PRP) improves tendon healing in patients undergoing arthroscopic rotator cuff repair. Prospective, randomized, controlled, double blind study; considering an alpha level of 5%, a power of 80%, 22 patients for group are needed. Fifty-three patients who underwent shoulder arthroscopy for the repair of a complete rotator cuff tear were randomly divided into 2 groups, using a block randomization procedure. A treatment group (N = 26) consisted of those who received an intraoperative application of PRP in combination with an autologous thrombin component. A control group (N = 27) consisted of those who did not receive that treatment. Patients were evaluated with validated outcome scores. A magnetic resonance image (MRI) was performed in all cases at more than 1 year post-op. All patients had the same accelerated rehabilitation protocol. The 2 groups were homogeneous. The pain score in the treatment group was lower than the control group at 3, 7, 14, and 30 days after surgery (P < .05). On the Simple Shoulder Test (SST), University of California (UCLA), and Constant scores, strength in external rotation, as measured by a dynamometer, were significantly higher in the treatment group than the control group at 3 months after surgery (strength in external rotation [SER]: 3 ± 1.6 vs 2.1 ± 1.3 kg; SST: 8.9 ± 2.2 vs 7.1 ± 2.7; UCLA: 26.9 ± 3 vs 24.2 ± 4.9; Constant: 65 ± 9 vs 57.8 ± 11; P < .05). There was no difference between the 2 groups after 6, 12, and 24 months. The follow-up MRI showed no significant difference in the healing rate of the rotator cuff tear. In the subgroup of grade 1 and 2 tears, with less retraction, SER in the PRP group was significant higher at 3, 6, 12, and 24 months postoperative (P < .05). The results of our study showed autologous PRP reduced pain in the first postoperative months. The long-term results of subgroups of grade 1 and 2 tears suggest that PRP positively affected cuff rotator healing. Copyright © 2011 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Jo, Chris Hyunchul; Shin, Ji Sun; Shin, Won Hyoung; Lee, Seung Yeon; Yoon, Kang Sup; Shin, Sue
2015-09-01
Two main questions about the use of platelet-rich plasma (PRP) for regeneration purposes are its effect on the speed of healing and the quality of healing. Despite recent numerous studies, evidence is still lacking in this area, especially in a representative patient population with medium to large rotator cuff tears. To assess the efficacy of PRP augmentation on the speed and quality of healing in patients undergoing arthroscopic repair for medium to large rotator cuff tears. Randomized controlled trial; Level of evidence, 1. A total of 74 patients scheduled for arthroscopic repair of medium to large rotator cuff tears were randomly assigned to undergo either PRP-augmented repair (PRP group) or conventional repair (conventional group). In the PRP group, 3 PRP gels (3 × 3 mL) were applied to each patient between the torn end and the greater tuberosity. The primary outcome was the Constant score at 3 months after surgery. Secondary outcome measures included the visual analog scale (VAS) for pain, range of motion (ROM), muscle strength, overall satisfaction and function, functional scores, retear rate, and change in the cross-sectional area (CSA) of the supraspinatus muscle. There was no difference between the 2 groups in the Constant score at 3 months (P > .05). The 2 groups had similar results on the VAS for pain, ROM, muscle strength, overall satisfaction and function, and other functional scores (all P > .05) except for the VAS for worst pain (P = .043). The retear rate of the PRP group (3.0%) was significantly lower than that of the conventional group (20.0%) (P = .032). The change in 1-year postoperative and immediately postoperative CSAs was significantly different between the 2 groups: -36.76 ± 45.31 mm(2) in the PRP group versus -67.47 ± 47.26 mm(2) in the conventional group (P = .014). Compared with repairs without PRP augmentation, the current PRP preparation and application methods for medium to large rotator cuff repairs significantly improved the quality, as evidenced by a decreased retear rate and increased CSA of the supraspinatus, but not the speed of healing. However, further studies may be needed to investigate the effects of PRP on the speed of healing without risking the quality. © 2015 The Author(s).
Characteristics of HY-180 and Ti-100 for Welded High Strength Structures
1974-12-01
materials in welded structures are reported. The 10Ni-8Co-2Cr-lMo steel arid the Ti- 6Al -2Cb-lTa-0. 8Mo titanium alloy were selected as candidate...only li- 6Al -iCb-na-0.»Mo (Ti-6-2-1-1) and’Ii- 6Al - 4V are competitive with 10Ni-8Co-2Cr-lMo steel on a strength-weight basis, while possessing ade...Ti- 6Al -2Cb-lTa-0. 8Mo has better toughness in plate form, based upon dynamic tear properties. There- fore the Ti- 6Al -2Cb-lTa-0.8Mo titanium alloy
Reinforcement of SBR/waste rubber powder vulcanizate with in situ generated zinc dimethacrylate
NASA Astrophysics Data System (ADS)
Wang, X. P.; Cheng, B. K.; Zhang, X.; Jia, D. M.
2016-07-01
Methyl acrylic acid/zinc oxide (MAA/ZnO) was introduced to modify styrene- butadiene rubber/waste rubber powder (SBR/WRP) composites by blending. The enhanced mechanical properties and processing ability were presumably originated from improved compatibility and interfacial interaction between WRP and the SBR matrix by the in situ polymerization of zinc dimethacrylate (ZDMA). A refined interface of the modified SBR/WRP composite was observed by scanning electron microscopy. The formation of ZDMA significantly increased the ionic bond content in the vulcanizate, resulting in exceptional mechanical performance. The comprehensive mechanical properties including tensile strength, tear strength and dynamic heat-building performance reached optimum values with 16 phr MAA.
Threshold Tear Strength of some Molecular Networks.
1981-04-03
Attn: Dr. F. Roberto Office of Naval Research 1 AFSC Western Office Andrews AFB, Code DLFP 1030 East Green Street Washington, DC 20334 Pasadena, CA...of Chemical & Office Atmospheric Sciences 495 Summer Street Bolling Air Force Base Boston, MA 02210 Washington, DC 20332 Attn: Dr. L. Peebles Dr. A...Plaza Suite 601 Bolling Air Force Base San Francisco, CA 94102 Washington, DC 20332 Attn: Dr. P. A. Miller Attn: Dr. L. H. Caveny Defense Technical
The Effects of the Air Cast Sports Stirrup on Postural Sway in Normal Males
1993-01-01
Pittsburgh Pittsburgh, PAI Paula Sammarone, MA, ATC Date Rangos School of Health Sciences I Director, Athletic Training Duquesne University I Pittsburgh, PA I...sprain occurs, tearing of the ligaments also occur, which results in de- afferentization of the articular nerves (20). 1 Several treatment modalities...intermediate ranges. Articular nerve fibers have lower tensile strength than collagen fibers (21). Since most inversion injuries of the ankle result in some
Mechanical strength of welding zones produced by material extrusion additive manufacturing.
Davis, Chelsea S; Hillgartner, Kaitlyn E; Han, Seung Hoon; Seppala, Jonathan E
2017-08-01
As more manufacturing processes and research institutions adopt customized manufacturing as a key element in their design strategies and finished products, the resulting mechanical properties of parts produced through additive manufacturing (AM) must be characterized and understood. In material extrusion (MatEx), the most recently extruded polymer filament must bond to the previously extruded filament via polymer diffusion to form a "weld". The strength of the weld limits the performance of the manufactured part and is controlled through processing conditions. Under-standing the role of processing conditions, specifically extruder velocity and extruder temperature, on the overall strength of the weld will allow optimization of MatEx-AM parts. Here, the fracture toughness of a single weld is determined through a facile "trouser tear" Mode III fracture experiment. The actual weld thickness is observed directly by optical microscopy characterization of cross sections of MatEx-AM samples. Representative data of weld strength as a function of printing parameters on a commercial 3D printer demonstrates the robustness of the method.
Deeken, Corey R; Abdo, Michael S; Frisella, Margaret M; Matthews, Brent D
2011-01-01
For meshes to be used effectively for hernia repair, it is imperative that engineers and surgeons standardize the terminology and techniques related to physicomechanical evaluation of these materials. The objectives of this study were to propose standard techniques, perform physicomechanical testing, and classify materials commonly used for inguinal hernia repair. Nine meshes were evaluated: 4 polypropylene, 1 polyester, 1 polytetrafluoroethylene, and 3 partially absorbable. Physical properties were determined through image analysis, laser micrometry, and density measurements. Biomechanical properties were determined through suture retention, tear resistance, uniaxial, and ball burst testing with specimens tested in 2 different orientations. A 1-way ANOVA with Tukey's post-test or a t-test were performed, with p < 0.05. Significant differences were observed due to both mesh type and orientation. Areas of interstices ranged from 0.33 ± 0.01 mm² for ProLite (Atrium Medical Corp) and C-QUR Lite (Atrium Medical Corp) Large to 4.10 ± 0.06 mm² for ULTRAPRO (Ethicon), and filament diameters ranged from 99.00 ±8.1 μm for ProLite Ultra (Atrium Medical Corp) and C-QUR Lite Small to 338.8 ± 3.7 μm for Parietex Flat Sheet TEC (Covidien). These structural characteristics influenced biomechanical properties such as tear resistance and tensile strength. ProLite Ultra, C-QUR Lite Small, ULTRAPRO and INFINIT (WL Gore & Associates) did not resist tearing as effectively as the others. All meshes exhibited supraphysiologic burst strengths except INFINIT and ULTRAPRO. Significant differences exist between the physicomechanical properties of polypropylene, polyester, polytetrafluoroethylene, and partially absorbable mesh prostheses commonly used for inguinal hernia repair. Orientation of the mesh was also shown to be critical for the success of meshes, particularly those demonstrating anisotropy. Copyright © 2011 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
Rimmke, Nathan; Maerz, Tristan; Cooper, Ross; Yadavalli, Sailaja; Anderson, Kyle
2016-01-01
To assess the retear rate, retear size and location, the clinical impact of a retear, and preoperative patient factors related to postoperative outcome after arthroscopic suture bridge rotator cuff repair. Fifty six patients with an isolated, full-thickness supraspinatus tendon tear who underwent arthroscopic suture bridge rotator cuff repair were retrospectively identified. Patients were evaluated and rotator cuff integrity was assessed using ultrasonography. Visual analog score (VAS), the American Shoulder and Elbow Surgeon (ASES) score, shoulder range of motion and strength were used for clinical evaluation. Retears were assessed for size and location on ultrasonography. Forty two patients (75%) aged a mean 59.7 ± 8.6 years (range 41-79 years) were available for follow-up at a mean 13.5 months. Postoperative evaluation indicated significant improvements in ASES score (49.76 ± 18.2 to 86.57 ± 13.4, P < 0.001), VAS pain score (4.69 ± 2.17 to 0.63 ± 1.29, P < 0.001), forward elevation range of motion (144.1° ± 29.9 to 159.69° ± 13.9, P = 0.002), and internal rotation ROM (44.13° ± 12.0 to 52.09° ± 12.0, P = 0.003). The retear rate was 14.28% (6/42). Patients with retears were not older (P = 0.526) but had a larger preoperative tear size (3.25 cm ± 0.5 vs. 2.05 cm ± 0.48, P < 0.001). Preoperative tear size was significantly associated with a postoperative retear (P < 0.001). The duration of preoperative symptoms was significantly associated with pain (P = 0.029), pain improvement (P = 0.013), internal rotation ROM (P = 0.002), and internal rotation strength (P = 0.004). Arthroscopic suture bridge repair provides good clinical results with a low retear rate. The duration of preoperative symptoms was associated with postoperative outcome, indicating that delaying surgery may result in inferior outcomes. IV, Case Series.
Lorbach, Olaf; Kieb, Matthias; Raber, Florian; Busch, Lüder C; Kohn, Dieter M; Pape, Dietrich
2013-01-01
The double-row suture bridge repair was recently introduced and has demonstrated superior biomechanical results and higher yield load compared with the traditional double-row technique. It therefore seemed reasonable to compare this second generation of double-row constructs to the modified single-row double mattress reconstruction. The repair technique, initial tear size, and tendon subregion will have a significant effect on 3-dimensional (3D) cyclic displacement under additional static external rotation of a modified single-row compared with a double-row rotator cuff repair. Controlled laboratory study. Rotator cuff tears (small to medium: 25 mm; medium to large: 35 mm) were created in 24 human cadaveric shoulders. Rotator cuff repairs were performed as modified single-row or double-row repairs, and cyclic loading (10-60 N, 10-100 N) was applied under 20° of external rotation. Radiostereometric analysis was used to calculate cyclic displacement in the anteroposterior (x), craniocaudal (y), and mediolateral (z) planes with a focus on the repair constructs and the initial tear size. Moreover, differences in cyclic displacement of the anterior compared with the posterior tendon subregions were calculated. Significantly lower cyclic displacement was seen in small to medium tears for the single-row compared with double-row repair at 60 and 100 N in the x plane (P = .001) and y plane (P = .001). The results were similar in medium to large tears at 100 N in the x plane (P = .004). Comparison of 25-mm versus 35-mm tears did not show any statistically significant differences for the single-row repairs. In the double-row repairs, lower gap formation was found for the 35-mm tears (P ≤ .05). Comparison of the anterior versus posterior tendon subregions revealed a trend toward higher anterior gap formation, although this was statistically not significant. The tested single-row reconstruction achieved superior results in 3D cyclic displacement to the tested double-row repair. Extension of the initial rupture size did not have a negative effect on the biomechanical results of the tested constructs. Single-row repairs with modified suture configurations provide comparable biomechanical strength to double-row repairs. Furthermore, as increased gap formation in the early postoperative period might lead to failure of the construct, a strong anterior fixation and restricted external rotation protocol might be considered in rotator cuff repairs to avoid this problem.
Kim, Jong Ok; Lee, Jong-Ho; Kim, Kwang-Sup; Ji, Jong-Hun; Koh, Sung-Jun; Lee, Jae-Ho
2017-11-01
This study investigated the efficacy of the bridging repair using an acellular dermal matrix (ADM) and an ADM with stem cells in rabbits. Also investigated were clinical outcomes of ADM bridging repair for large to massive rotator cuff tears. ADM, with and without stem cells, was used to cover a 5- × 5-mm-sized cuff defect in 17 rabbits, and biomechanical, histologic, and immunohistochemical analyses were conducted. Also evaluated were 24 patients with large to massive rotator cuff tears after ADM bridging repair. In the biomechanical test, the normal rotator cuff, cuff with ADM plus stem cells, and cuff with ADM in the rabbit model showed a maximum load (N) of 287.3, 217.5, and 170.3 and ultimate tensile strength (N/mm 2 ) of 11.1, 8.0, and 5.2, respectively. Histologically, the cuff tendons with the ADM or ADM plus stem cells showed characteristically mature tendons as time passed. In the clinical study, the mean American Shoulder and Elbow Surgeons score improved from preoperative 50 to postoperative 83, the University of California Los Angeles Shoulder Rating Scale from 17 to 30, and the Simple Shoulder Test from 4 to 8, respectively. No further fatty deteriorations or muscle atrophy were observed on follow-up magnetic resonance imaging. A retear was found in 5 of 24 patients (21%). Bridging repair with ADM or stem cells in the rabbit model showed cellular infiltration into the graft and some evidence of neotendon formation. Clinically, ADM repair was a safe alternative that did not show any further fatty deterioration nor muscle atrophy in large to massive rotator cuff tears. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
A comparison of basal and eye-flush tears for the analysis of cat tear proteins.
Petznick, Andrea; Evans, Margaret D M; Madigan, Michele C; Markoulli, Maria; Garrett, Qian; Sweeney, Deborah F
2011-02-01
To identify a rapid and effective tear collection method providing sufficient tear volume and total protein content (TPC) for analysis of individual proteins in cats. Domestic adult short-haired cats (12-37 months; 2.7-6.6 kg) were used in the study. Basal tears without stimulation and eye-flush tears after instillation of saline (10 μl) were collected using microcapillary tubes from animal eyes either unwounded control or wounded with 9-mm central epithelial debridement giving four groups with n = 3. Tear comparisons were based on total time and rate for tear collection, TPC using micro bicinchoninic acid (BCA), tear immunoglobulin A (IgA), total matrix-metalloproteinase (MMP)-9 concentration using sandwich enzyme-linked immunosorbent assay (ELISA) and MMP-9 activity. Eye-flush tears were collected significantly faster than basal tears in wounded eyes with higher rates for tear collection in unwounded control and wounded eyes. TPC was significantly lower in eye-flush tears compared to basal tears. The relative proportion of tear IgA normalized to TPC (% IgA of TPC) was not significantly different between basal and eye-flush tears. In unwounded control eyes, MMP-9 was slightly higher in eye-flush than in basal tears; activity of MMP-9 in both tear types was similar. In wounded eyes, eye-flush tears showed highest MMP-9 levels and activity on Day 1, which subsequently decreased to Day 7. MMP-9 activity in basal tears from wounded eyes did not display changes in expression. Eye-flush tears can be collected rapidly providing sufficient tear volume and TPC. This study also indicates that eye-flush tears may be more suitable than basal tears for the analysis of MMPs following corneal wounding. © 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.
Medial Meniscus Posterior Root Tear: A Comprehensive Review
Lee, Dhong Won; Ha, Jeong Ku
2014-01-01
Damage to the medial meniscus root, for example by a complete radial tear, destroys the ability of the knee to withstand hoop strain, resulting in contact pressure increases and kinematic alterations. For these reasons, several techniques have been developed to repair the medial meniscus posterior root tear (MMPRT), many of which have shown complete healing of the repaired MMPRT. However, efforts to standardize or optimize the treatment for MMPRT are much needed. When planning a surgical intervention for an MMPRT, strict surgical indications regarding the effect of pullout strength on the refixed root, bony degenerative changes, mechanical alignment, and the Kellgren-Lawrence grade should be considered. Although there are several treatment options and controversies, the current trend is to repair the MMPRT using various techniques including suture anchors and pullout sutures if the patient meets the indications. However, there are still debates on the restoration of hoop tension and prevention of arthritis after repair and further biomechanical and clinical studies should be conducted in the future. The aim of this article was to review and summarize the recent literature regarding various diagnosis and treatment strategies of MMPRT, especially focusing on conflict issues including whether repair techniques can restore the main function of normal meniscus and which is the best suture technique to repair the MMPRT. The authors attempted to provide a comprehensive review of previous studies ranging from basic science to current surgical techniques. PMID:25229041
Medial meniscus posterior root tear: a comprehensive review.
Lee, Dhong Won; Ha, Jeong Ku; Kim, Jin Goo
2014-09-01
Damage to the medial meniscus root, for example by a complete radial tear, destroys the ability of the knee to withstand hoop strain, resulting in contact pressure increases and kinematic alterations. For these reasons, several techniques have been developed to repair the medial meniscus posterior root tear (MMPRT), many of which have shown complete healing of the repaired MMPRT. However, efforts to standardize or optimize the treatment for MMPRT are much needed. When planning a surgical intervention for an MMPRT, strict surgical indications regarding the effect of pullout strength on the refixed root, bony degenerative changes, mechanical alignment, and the Kellgren-Lawrence grade should be considered. Although there are several treatment options and controversies, the current trend is to repair the MMPRT using various techniques including suture anchors and pullout sutures if the patient meets the indications. However, there are still debates on the restoration of hoop tension and prevention of arthritis after repair and further biomechanical and clinical studies should be conducted in the future. The aim of this article was to review and summarize the recent literature regarding various diagnosis and treatment strategies of MMPRT, especially focusing on conflict issues including whether repair techniques can restore the main function of normal meniscus and which is the best suture technique to repair the MMPRT. The authors attempted to provide a comprehensive review of previous studies ranging from basic science to current surgical techniques.
Arthroscopic assisted tendon reconstruction for triangular fibrocartilage complex irreparable tears.
Luchetti, R; Atzei, A
2017-05-01
We report our 11-year experience of performing arthroscopically assisted triangular fibrocartilage complex reconstruction in the treatment of chronic distal radio-ulnar joint instability resulting from irreparable triangular fibrocartilage complex injuries. Eleven patients were treated. Three skin incisions were made in order to create radial and ulna tunnels for passage of the tendon graft, which is used to reconstruct the dorsal and palmar radio-ulnar ligaments, under fluoroscopic and arthroscopic guidance. At a mean follow-up of 68 months all but one had a stable distal radio-ulnar joint. Pain and grip strength, Mayo wrist score, Disability of the Arm Hand and Shoulder and patient-rated wrist and hand evaluation scores improved. The ranges of forearm rotation remained largely unchanged. Complications included an early tendon graft tear, two late-onset graft ruptures, one ulna styloid fracture during surgery and persistent wrist discomfort during forearm rotation requiring tendon graft revision in one case. An arthroscopic assisted approach for triangular fibrocartilage complex reconstruction appears safe and produces comparable results with the open technique. IV.
Thermal stress analysis of space shuttle orbiter wing skin panel and thermal protection system
NASA Technical Reports Server (NTRS)
Ko, William L.; Jenkins, Jerald M.
1987-01-01
Preflight thermal stress analysis of the space shuttle orbiter wing skin panel and the thermal protection system (TPS) was performed. The heated skin panel analyzed was rectangular in shape and contained a small square cool region at its center. The wing skin immediately outside the cool region was found to be close to the state of elastic instability in the chordwise direction based on the conservative temperature distribution. The wing skin was found to be quite stable in the spanwise direction. The potential wing skin thermal instability was not severe enough to tear apart the strain isolation pad (SIP) layer. Also, the preflight thermal stress analysis was performed on the TPS tile under the most severe temperature gradient during the simulated reentry heating. The tensile thermal stress induced in the TPS tile was found to be much lower than the tensile strength of the TPS material. The thermal bending of the TPS tile was not severe enough to cause tearing of the SIP layer.
Fujii, Masataka; Furumatsu, Takayuki; Xue, Haowei; Miyazawa, Shinichi; Kodama, Yuya; Hino, Tomohito; Kamatsuki, Yusuke; Ozaki, Toshifumi
2017-10-01
The purpose of this study was to compare the load-to-failure of different common suturing techniques with a new technique for the medial meniscus posterior root tear (MMPRT). Thirty porcine medial menisci were randomly assigned to three suturing techniques used for transtibial pullout repair of the MMPRT (n = 10 per group). Three different meniscal suture configurations were studied: the two simple suture (TSS) technique, the conventional modified Mason-Allen suture (MMA) technique, and the new MMA technique using the FasT-Fix combined with the Ultrabraid (F-MMA). The ultimate failure load was tested using a tensile testing machine. The MMA and F-MMA groups demonstrated significantly higher failure loads than the TSS group (P = 0.0003 and P = 0.0005, respectively). No significant differences were observed between the MMA and F-MMA groups (P = 0.734). The ultimate failure load was significantly greater in the F-MMA than the TSS group and similar to the conventional MMA technique.
Single- and double-row repair for rotator cuff tears - biology and mechanics.
Papalia, Rocco; Franceschi, Francesco; Vasta, Sebastiano; Zampogna, Biagio; Maffulli, Nicola; Denaro, Vincenzo
2012-01-01
We critically review the existing studies comparing the features of single- and double-row repair, and discuss suggestions about the surgical indications for the two repair techniques. All currently available studies comparing the biomechanical, clinical and the biological features of single and double row. Biomechanically, the double-row repair has greater performances in terms of higher initial fixation strength, greater footprint coverage, improved contact area and pressure, decreased gap formation, and higher load to failure. Results of clinical studies demonstrate no significantly better outcomes for double-row compared to single-row repair. Better results are achieved by double-row repair for larger lesions (tear size 2.5-3.5 cm). Considering the lack of statistically significant differences between the two techniques and that the double row is a high cost and a high surgical skill-dependent technique, we suggest using the double-row technique only in strictly selected patients. Copyright © 2012 S. Karger AG, Basel.
De Smet, A A; Graf, B K
1994-04-01
MR imaging of the knee is a valuable technique for diagnosing meniscal tears, but some tears found at arthroscopy are not shown on MR imaging. The purpose of this study was to determine whether or not tears were more frequently missed in the presence of an anterior cruciate ligament tear or when tears had certain locations or configurations. We reviewed the original MR reports and surgical records of 400 patients who had both an MR examination and arthroscopy of the knee. Using chi 2 analysis, we examined how the sensitivity for detecting meniscal tears varied with the presence of a tear of the anterior cruciate ligament, with the location of the tear within the meniscus, and among six configurations of meniscal tears. We also studied whether sensitivity decreased with an increasing delay between MR examination and arthroscopy. In the presence of a tear of the anterior cruciate ligament, the sensitivity decreased from 0.97 to 0.88 (p = .016) for medial meniscal tears and from 0.94 to 0.69 (p = .0005) for lateral tears. The overall sensitivity for lateral meniscal tears was significantly less for posterior (p = .001) and peripheral (p = .005) tears than for other tear locations or configurations. The sensitivities did not significantly differ between tear locations and configurations in the medial meniscus or with an increasing delay until arthroscopy. Patients with a torn anterior cruciate ligament were more likely to have peripheral tears of the medial meniscus (p = .00004) and posterior (p = .0004) and peripheral (p = .04) tears of the lateral meniscus. Because of their location and configuration, meniscal tears associated with an anterior cruciate ligament injury are more difficult to detect on MR images than are tears in knees with an intact ligament. If a tear of the anterior cruciate ligament is detected, special attention should be given to the subtle peripheral tears that may be present in either meniscus, but most commonly in the posterior horn of the lateral meniscus. These tears are especially difficult to detect on MR images.
1999-08-01
directional Nitinol- ~ Reinforced / • CoUpoly - Niti 10 . . . oUnyl - Nitl 10 ----- BOU fabric 30 40 50 blade travel (mm) 60 Tongue· Tear 140...To ughness Results 120 100 ;e i 80 ~ c .::; !!’ 60 .s 40 20 0 2 CoUnyl bi·directionai- Niti 20...and fill yarns that provides the ripstop effect. Cot/Nyl 5- Niti /in. (0.003") - Cot/Nyl-5 Baseline cotton/nylon plain weave with 5 Nitinol fibers per
Threshold Tear Strength of Elastomers.
1982-04-01
O 0 0 C~j C-J C7,) 0DY 122 DISTRIBUTION LIST No. Cooes No. Cooies Dr. L.V. Schmidt I Dr. F. Roberto 1 ’Assistant Secretary of the Navy Code AFRPL MKPA...Research Scientific Advisor Directorate of Aerospace Sciences Commandant of the Marine Corps Bolling Air Force Base Code RD-i Washington, D.C. 20332...Directorate of Chemical Sciences Arlington, VA 22217 Bolling Air Force Base Washington, D.C. 20332 Mr. David Siegel D Office of Naval Research Dr. John S
Tear dynamics in healthy and dry eyes.
Cerretani, Colin F; Radke, C J
2014-06-01
Dry-eye disease, an increasingly prevalent ocular-surface disorder, significantly alters tear physiology. Understanding the basic physics of tear dynamics in healthy and dry eyes benefits both diagnosis and treatment of dry eye. We present a physiological-based model to describe tear dynamics during blinking. Tears are compartmentalized over the ocular surface; the blink cycle is divided into three repeating phases. Conservation laws quantify the tear volume and tear osmolarity of each compartment during each blink phase. Lacrimal-supply and tear-evaporation rates are varied to reveal the dependence of tear dynamics on dry-eye conditions, specifically tear osmolarity, tear volume, tear-turnover rate (TTR), and osmotic water flow. Predicted periodic-steady tear-meniscus osmolarity is 309 and 321 mOsM in normal and dry eyes, respectively. Tear osmolarity, volume, and TTR all match available clinical measurements. Osmotic water flow through the cornea and conjunctiva contribute 10 and 50% to the total tear supply in healthy and dry-eye conditions, respectively. TTR in aqueous-deficient dry eye (ADDE) is only half that in evaporative dry eye (EDE). The compartmental periodic-steady tear-dynamics model accurately predicts tear behavior in normal and dry eyes. Inclusion of osmotic water flow is crucial to match measured tear osmolarity. Tear-dynamics predictions corroborate the use of TTR as a clinical discriminator between ADDE and EDE. The proposed model is readily extended to predict the dynamics of aqueous solutes such as drugs or fluorescent tags.
The tear turnover and tear clearance tests - a review.
Garaszczuk, Izabela K; Montes Mico, Robert; Iskander, D Robert; Expósito, Alejandro Cerviño
2018-03-01
The aim is to provide a summary of methods available for the assessment of tear turnover and tear clearance rates. The review defines tear clearance and tear turnover and describes their implication for ocular surface health. Additionally, it describes main types of techniques for measuring tear turnover, including fluorescein tear clearance tests, techniques utilizing electromagnetic spectrum and tracer molecule and novel experimental techniques utilizing optical coherence tomography and fluorescein profilometry. Areas covered: Internet databases (PubMed, Science Direct, Google Scholar) and most frequently cited references were used as a principal resource of information on tear turnover rate and tear clearance rate, presenting methodologies and equipment, as well as their definition and implications for the anterior eye surface health and function. Keywords used for data-search were as follows: tear turnover, tear clearance, fluorescein clearance, scintigraphy, fluorophotometry, tear flow, drainage, tear meniscus dynamics, Krehbiel flow and lacrimal functional unit. Expert commentary: After decades, the topic of tear turnover assessment has been reintroduced. Recently, new techniques have been developed to propose less invasive, less time consuming and simpler methodologies for the assessment of tear dynamics that have the potential to be utilized in clinical practice.
Jo, Chris Hyunchul; Shin, Ji Sun; Lee, Young Gil; Shin, Won Hyoung; Kim, Hyang; Lee, Seung Yeon; Yoon, Kang Sup; Shin, Sue
2013-10-01
Platelet-rich plasma (PRP) is expected to have a biological augmentation potential in the healing of various diseases and injuries, including rotator cuff tears. However, few evaluations have been performed specifically for large to massive tears. To assess the efficacy of PRP augmentation in patients undergoing arthroscopic repair for large to massive rotator cuff tears. Randomized controlled trial; Level of evidence, 1. A total of 48 patients scheduled for arthroscopic repair of large to massive rotator cuff tears were randomly assigned to receive either PRP-augmented (PRP group) or conventional treatment (conventional group). In the PRP group, 3 PRP gels (3 × 3 mL) were applied to each patient between the torn end and the greater tuberosity. The primary outcome measure was the retear rate assessed by magnetic resonance imaging (MRI) or computed tomographic arthrography (CTA) at a minimum of 9 months after surgery. Secondary outcome measures included pain, range of motion, muscle strength, overall satisfaction, functional scores, and the change in cross-sectional area (CSA) of the supraspinatus. The retear rate of the PRP group (20.0%) was significantly lower than that of the conventional group (55.6%) (P = .023). Clinical outcomes showed no statistical difference between the 2 groups (all P > .05) except for the overall function (P = .043). The change in 1-year postoperative and immediately postoperative CSA was significantly different between the 2 groups: -15.54 ± 94.34 mm² in the PRP group versus -85.62 ± 103.57 mm² in the conventional group (P = .047). The application of PRP for large to massive rotator cuff repairs significantly improved structural outcomes, as evidenced by a decreased retear rate and increased CSA of the supraspinatus compared with repairs without PRP augmentation. While there was no significant difference in clinical outcomes except the overall shoulder function after 1-year follow-up, better structural outcomes in the PRP group might suggest improved clinical outcomes at longer term follow-up.
Kim, Yang-Soo; Kim, Sung-Eun; Bae, Sung-Ho; Lee, Hyo-Jin; Jee, Won-Hee; Park, Chang Kyun
2017-07-01
The purpose of this study was to analyse the natural course of symptomatic full-thickness and partial-thickness rotator cuff tears treated non-operatively and to identify risk factors affecting tear enlargement. One hundred and twenty-two patients who received non-surgical treatment for a partial- or full-thickness supraspinatus tear were included in this study. All rotator cuff tears were diagnosed with magnetic resonance imaging (MRI), and the same modality was used for follow-up studies. Follow-up MRI was performed after at least a 6-month interval. We evaluated the correlation between tear enlargement and follow-up duration. Eleven risk factors were analysed by both univariate and multivariate analyses to identify factors that affect enlargement of rotator cuff tears. The mean follow-up period was 24.4 ± 19.5 months. Out of 122 patients, 34 (27.9%) patients had an initial full-thickness tear and 88 (72.1%) patients had a partial-thickness tear. Considering all patients together, tear size increased in 51/122 (41.8%) patients, was unchanged in 65/122 (53.3%) patients, and decreased in 6/122 (4.9%) patients. Tear size increased for 28/34 (82.4%) patients with full-thickness tears and 23/88 (26.1%) patients with partial-thickness tears. From the two groups which were followed over 12 months, a higher rate of enlargement was observed in full-thickness tears than in partial-thickness tears (6-12 months, n.s.; 12-24 months, P = 0.002; over 24 months, P < 0.001). Logistic regression revealed that having a full-thickness tear was the most reliable risk factor for tear progression (P < 0.001). This study found that 28/34 (82.4%) of symptomatic full-thickness rotator cuff tears and 23/88 (26.1%) of symptomatic partial-thickness tears increased in size over a follow-up period of 6-100 months. Full-thickness tears showed a higher rate of enlargement than partial-thickness tears regardless of the follow-up duration. Univariate and multivariate analyses suggested that full-thickness tear was the most reliable risk factor for tear enlargement. The clinical relevance of these observations is that full-thickness rotator cuff tears treated conservatively should be monitored more carefully for progression than partial-thickness tears. IV.
Yamamoto, Nobuyuki; Mineta, Mitsuyoshi; Kawakami, Jun; Sano, Hirotaka; Itoi, Eiji
2017-09-01
The risk factors for tear progression in symptomatic rotator cuff tears have not been clarified yet. It is important for orthopaedic surgeons to know the natural course of tear progression when nonoperative management is to be chosen. Tears in younger patients, high-activity patients, or heavy laborers would progress in size more than those in older patients, low-activity patients, or light laborers. Case-control study; Level of evidence, 3. Two hundred twenty-five consecutive patients with symptomatic rotator cuff tears visited our institute between 2009 and 2015. Of these, 174 shoulders of 171 patients (mean age, 66.9 years) who underwent at least 2 magnetic resonance imaging (MRI) examinations were prospectively enrolled. The mean follow-up was 19 months. Tear progression was defined as positive when the tear size increased by ≥2 mm. The demographic factors that were analyzed by multivariate analysis included age, sex, hand dominance, smoking, alcohol drinking, hypercholesterolemia, sports participation, job type, tear size, and tear type (full or partial thickness). Of the 174 shoulders, 82 shoulders (47%) showed tear progression. The mean (±SD) tear length and width in the progression group on final MRI were 23.1 ± 12.5 mm and 17.3 ± 9.6 mm, respectively; the tear size progressed by a mean 5.8 ± 5.6 mm in length and 3.1 ± 5.2 mm in width. The mean propagation speed was 3.8 mm/y in length and 2.0 mm/y in width. The size of full-thickness tears significantly increased compared with that of articular-sided partial-thickness tears ( P = .0215). The size of medium tears significantly increased compared with that of other tears ( P < .0001). According to the logistic regression analysis, smoking was significantly correlated with tear progression ( P = .026). Subgroup analyses showed that male sex, hand dominance, and trauma were correlated with tear progression. Age, alcohol drinking, hypercholesterolemia, sports participation, and job type did not show any correlation with tear progression. The tear size of symptomatic rotator cuff tears progressed in 47% of the shoulders during a mean of 19 months, and the speed of progression was 3.8 mm/y in length and 2.0 mm/y in width. The risk factors for tear progression were (1) a medium-sized tear, (2) a full-thickness tear, and (3) smoking.
Structure and microanalysis of tear film ferning of camel tears, human tears, and Refresh Plus.
Am, Masmali; Ra, Fagehi; El-Naggar, Ahmad H; Tm, Almubrad
2018-01-01
This study aimed to investigate the tear ferning pattern and chemical elements of the tear film of camel tears compared with human tears and Refresh Plus eye lubricant. Refresh Plus was used as a control because it provides a healthy ferning pattern, due to the presence of an optimum ratio of carboxymethylcellulose (CMC) sodium and electrolytes. The main research focus is elucidating the viability of camel tear film in the dry, harsh environment of the desert. The tears were collected from five camels, five male desert workers (20-25 years old) at a small village located 100 km from Riyadh, Saudi Arabia, and five male subjects (20-25 years old) from Riyadh. A small drop (1 μl) of tears was dried on a glass slide and observed under a light (Olympus BX1) and scanning electron microscope (Inspect S50, Field Electron and Ion Company [FEI]). Energy-dispersive X-ray spectroscopy (EDS) of the tear film and Refresh Plus were investigated with a JEOL 1400 scanning transmission electron microscope. The camel tear film pattern was surrounded by thick, peripheral, homogenous layers containing small oily droplets, particles, and tiny branches in the tear ferning. The tear ferning of the camel was grade 0-1, whereas the tear ferning of human tears and Refresh Plus was grade 1-2. The mass percentage of chloride was highest in the camel tears. The mass percentage of potassium in the camel tears was greater than that in the human tears, but it was less than that in the Refresh Plus lubricant. Camel tears exhibit a better quality than human tears and Refresh Plus lubricant do. The presence of oily droplet-like structures at the periphery of tear ferning suggests that camel tear film may have a higher quality and quantity of minerals and lubricants, which may help the animal to avoid eye dryness. Future work is required to investigate the identification of the elements present in the peripheral and central part of the tear ferning.
Ahn, Somin; Eom, Youngsub; Kang, Boram; Park, Jungboung; Lee, Hyung Keun; Kim, Hyo Myung; Song, Jong Suk
2018-05-01
To evaluate the effects of menthol-containing artificial tears on tear stimulation and ocular surface integrity in normal and dry eye rat models. A total of 54 male Lewis rats were used. The levels of tear secretion and tear MUC5AC concentrations were compared between the menthol-containing artificial tear-treated group (menthol group) and the vehicle-treated group (vehicle group). The groups were compared after a single instillation to evaluate the immediate effects, and after repeated instillation (five times a day for 5 days) to evaluate the longer-term effects. Tear lactate dehydrogenase (LDH) activity was measured to evaluate eye drop instillation-induced ocular surface damage. The effects of menthol-containing artificial tears were also evaluated in a dry eye rat model. After a single instillation of menthol-containing artificial tears, tear secretion increased from 4.37 (±0.75) mm at baseline to 7.37 (±1.60) mm. However, after repeated instillations, the effects of tear stimulation decreased. The tear MUC5AC concentration was significantly lower in the menthol group than in the vehicle group after a single instillation, but not after repeated instillation. However, the tear LDH concentration was significantly increased in the menthol group after repeated instillation. In the dry eye rat model, the extent of menthol-induced tear stimulation was reduced. Menthol-containing artificial tears increased tear secretion, but lowered the tear MUC5AC concentration. Menthol-induced tear stimulation was reduced after repeated instillation for 5 days and in the dry eye rat model. Conversely, repeated instillation of menthol-induced ocular surface damage, resulting in increased tear LDH activity.
Plasminogen activator activity in tears of pregnant women.
Csutak, Adrienne; Steiber, Zita; Tőzsér, József; Jakab, Attila; Berta, András; Silver, David M
2017-01-01
Plasminogen activator activity (PAA) in tears of pregnant women was investigated at various gestation times to assess the availability of plasminogen activator for aiding potential corneal wound healing processes during pregnancy. PAA was measured by a spectrophotometric method. The analysis used 91 tear samples from pregnant and non-pregnant women, supplemented with 10 additional tear PAA measurements from non-pregnant women obtained in a previous study. Tear levels of PAA in pregnant women formed a bimodal distribution. Either the tear PAA level was zero or non-zero during pregnancy. When non-zero, the tear PAA level was dissociated from gestation time and not different than non-pregnant and post-pregnant levels. The frequency of occurrence of zero level tear PAA increased with gestation: 16%, 17% and 46% had zero tear PAA in samples taken from women in the first, second and third trimester, respectively. Overall, of the tear samples taken from women during pregnancy, a total of 26% were at zero tear PAA. The remaining tear samples had non-zero tear PAA values throughout gestation equivalent to non-pregnant tear PAA values, suggesting local control of the source of PAA in tears. Given the importance of the plasminogen activator system in tears to wound healing in the cornea, and the high occurrence of zero tear PAA in our sample of pregnant women, elective corneal surgery would be contraindicated. If corneal surgery is nevertheless necessary, the tear PAA level would be worth checking and patients with low level should be closely observed during the postoperative period.
Mechanical Properties of Elastomeric Impression Materials: An In Vitro Comparison
De Angelis, Francesco; Caputi, Sergio; D'Amario, Maurizio; D'Arcangelo, Camillo
2015-01-01
Purpose. Although new elastomeric impression materials have been introduced into the market, there are still insufficient data about their mechanical features. The tensile properties of 17 hydrophilic impression materials with different consistencies were compared. Materials and Methods. 12 vinylpolysiloxane, 2 polyether, and 3 hybrid vinylpolyether silicone-based impression materials were tested. For each material, 10 dumbbell-shaped specimens were fabricated (n = 10), according to the ISO 37:2005 specifications, and loaded in tension until failure. Mean values for tensile strength, yield strength, strain at break, and strain at yield point were calculated. Data were statistically analyzed using one-way ANOVA and Tukey's tests (α = 0.05). Results. Vinylpolysiloxanes consistently showed higher tensile strength values than polyethers. Heavy-body materials showed higher tensile strength than the light bodies from the same manufacturer. Among the light bodies, the highest yield strength was achieved by the hybrid vinylpolyether silicone (2.70 MPa). Polyethers showed the lowest tensile (1.44 MPa) and yield (0.94 MPa) strengths, regardless of the viscosity. Conclusion. The choice of an impression material should be based on the specific physical behavior of the elastomer. The light-body vinylpolyether silicone showed high tensile strength, yield strength, and adequate strain at yield/brake; those features might help to reduce tearing phenomena in the thin interproximal and crevicular areas. PMID:26693227
Residual Strength Prediction of Fuselage Structures with Multiple Site Damage
NASA Technical Reports Server (NTRS)
Chen, Chuin-Shan; Wawrzynek, Paul A.; Ingraffea, Anthony R.
1999-01-01
This paper summarizes recent results on simulating full-scale pressure tests of wide body, lap-jointed fuselage panels with multiple site damage (MSD). The crack tip opening angle (CTOA) fracture criterion and the FRANC3D/STAGS software program were used to analyze stable crack growth under conditions of general yielding. The link-up of multiple cracks and residual strength of damaged structures were predicted. Elastic-plastic finite element analysis based on the von Mises yield criterion and incremental flow theory with small strain assumption was used. A global-local modeling procedure was employed in the numerical analyses. Stress distributions from the numerical simulations are compared with strain gage measurements. Analysis results show that accurate representation of the load transfer through the rivets is crucial for the model to predict the stress distribution accurately. Predicted crack growth and residual strength are compared with test data. Observed and predicted results both indicate that the occurrence of small MSD cracks substantially reduces the residual strength. Modeling fatigue closure is essential to capture the fracture behavior during the early stable crack growth. Breakage of a tear strap can have a major influence on residual strength prediction.
2014-01-01
Objective: We report the prevalence of surgical intervention on shoulder labral lesions detected at MR examinations and how surgeons describe labral tears seen at MR examinations in their arthroscopy reports. Methods: A retrospective review of 100 consecutive patients aged 50 years or younger who had shoulder labral tears on MR and went on to have surgery performed. It was determined whether surgical intervention was performed on the MR lesions. Results: Of these 100 patients, 72 had superior labral anterior to posterior (SLAP) tears, 38 had posterior labral tears and 28 had anterior labral tears on MR examination. All 100 patients went on to arthroscopy. All lesions described on MRI were described on arthroscopy. Of the 72 SLAP tears, 64 were described as fraying on arthroscopy with 51 debrided. The remaining eight SLAP tears were tacked surgically. Of the 38 posterior labral tears, 36 were described as fraying on arthroscopy with 29 debrided and 2 had surgical tacking performed. Of the 28 anterior labral tears described on MR examination, 26 had surgical tacking performed and 2 were debrided. There were four SLAP tears, two anterior labral tears and three posterior labral tears seen on arthroscopy but not seen on MR examination. Conclusion: In this series, a high percentage of SLAP tears and posterior labral tears described on MR examination did not have surgical tacking. Most anterior labral tears had surgical tacking. Based on the above, our surgeons request we describe superior and posterior labral lesions as fraying and/or tearing, unless we can see a displaced tear. Most anterior labral lesions are treated with surgical tacking. Advances in knowledge: MRI allows for sensitive detection of labral tears. The tears often are not clinically significant. PMID:24712320
Rotator cuff tears in children and adolescents: experience at a large pediatric hospital.
Zbojniewicz, Andrew M; Maeder, Matthew E; Emery, Kathleen H; Salisbury, Shelia R
2014-06-01
Prior literature, limited to small case series and case reports, suggests that rotator cuff tears are rare in adolescents. However, we have identified rotator cuff tears in numerous children and adolescents who have undergone shoulder MRI evaluation. The purpose of this study is to describe the prevalence and characteristics of rotator cuff tears in children and adolescents referred for MRI evaluation of the shoulder at a large pediatric hospital and to correlate the presence of rotator cuff tears with concurrent labral pathology, skeletal maturity and patient activity and outcomes. We reviewed reports from 455 consecutive non-contrast MRI and magnetic resonance arthrogram examinations of the shoulder performed during a 2-year period, and following exclusions we yielded 205 examinations in 201 patients (ages 8-18 years; 75 girls, 126 boys). Rotator cuff tears were classified by tendon involved, tear thickness (partial or full), surface and location of tear (when partial) and presence of delamination. We recorded concurrent labral pathology when present. Physeal patency of the proximal humerus was considered open, closing or closed. Statistical analysis was performed to evaluate for a relationship between rotator cuff tears and degree of physeal patency. We obtained patient activity at the time of injury, surgical reports and outcomes from clinical records when available. Twenty-five (12.2%) rotator cuff tears were identified in 17 boys and 7 girls (ages 10-18 years; one patient had bilateral tears). The supraspinatus tendon was most frequently involved (56%). There were 2 full-thickness and 23 partial-thickness tears with articular-side partial-thickness tears most frequent (78%). Insertional partial-thickness tears were more common (78%) than critical zone tears (22%) and 10 (43%) partial-thickness tears were delamination tears. Nine (36%) patients with rotator cuff tears had concurrent labral pathology. There was no statistically significant relationship between rotator cuff tears and physeal patency (P > 0.05). Most patients were athletes (76%). Five tears were confirmed at surgery. Poor clinical follow-up limited evaluation of patient outcomes. Rotator cuff tears can be identified during MRI examination of symptomatic child and adolescent shoulders and often consist of tear patterns associated with repetitive microtrauma in overhead athletic activities or with single traumatic events. Rotator cuff tears are seen throughout the range of skeletal maturity, often coexist with labral tears and typically are found in athletes.
NASA Astrophysics Data System (ADS)
Ahmad, Naseer; Kamal, Shahid; Raza, Zulfiqar Ali; Hussain, Tanveer
2017-03-01
The present study investigated multi-response optimization of certain input parameters viz. concentrations of oil and water repellent finish (Oleophobol CP-C®), dimethylol dihydroxy ethylene urea based cross linking agent (Knittex FEL) and curing temperature on some mechanical, (i.e. tear and tensile strengths), functional (i.e., water contact angle ‘WCA’, oil contact angle ‘OCA’) and comfort (i.e. crease recovery angle ‘CRA’, air permeability ‘AP’, and stiffness) properties of an oleo-hydrophobic finished fabric under response surface methodology and the desirability function. The results have been examined using analysis of variance (ANOVA) and desirability function for the identification of optimum levels of input variables. The ANOVA was employed also to identify the percentage contribution of process factors. Under the optimized conditions, which were obtained with a total desirability value of 0.7769, the experimental values of Oleophobol CP-C® (O-CPC), Knittex FEL (K-FEL) and curing temperature (C-Temp) agreed closely with the predicted values. The optimized process parameters for maximum WCA (135°), OCA (129°), AP (290 m s-1), CRA (214°), tear (1492 gf) and tensile (764 N) strengths and minimum stiffness (3.2928 cm) were found to be: concentration of OCP-C as 44.44 g l-1, concentration of cross linker K-FEL as 32.07 g l-1 and C-Temp as 161.81 °C.
Mansori, Ashraf El; Lording, Timothy; Schneider, Antoine; Dumas, Raphael; Servien, Elvire; Lustig, Sebastien
2018-05-26
Injury to the anterior cruciate ligament (ACL) is frequently accompanied by tears of the menisci. Some of these tears occur at the time of injury, but others develop over time in the ACL-deficient knee. The aim of this study was to evaluate the effects of the patient characteristics, time from injury (TFI), and posterior tibial slope (PTS) on meniscal tear patterns. Our hypothesis was that meniscal tears would occur more frequently in ACL-deficient knees with increasing age, weight, TFI, PTS, and in male patients. Of the ACL-injured patients, 362 were analyzed, and details of meniscal lesions were collected. The medial and lateral tibial slopes (MTS, LTS) were measured via computed tomography. Patient demographics, TFI, MTS, and LTS were correlated with the diagnosed meniscal tears. Of the patients, 113 had a medial meniscus (MM) tear, 54 patients had a lateral meniscus (LM) tear, 34 patients had tears of both menisci, and 161 patients had no meniscal tear. The most common tear location was the posterior horn (PH) of the MM, followed by tear involving the whole MM. Patient age, BMI, and TFI were significantly associated with the incidence of MM tear. Female patients had a higher incidence of injury than males in all tear sites except in the body and PH. Male patients had more vertical and peripheral tears. The median MTS and LTS for patients with MM tears were 7.0°and 8.7°, respectively, while those of patients with LM tears were 6.9° and 8.1°. Steeper LTS was significantly associated with tears of LM and of both menisci. Older age, male sex, increased BMI, and prolonged TFI were significant factors for the development of MM tears. An increase in the tibial slope, especially of the lateral plateau, seems to increase the risk of tear of the LM and of both menisci. Level III.
Koike, Yoichi; Sano, Hirotaka; Kita, Atushi; Itoi, Eiji
2013-09-01
Some patients with rotator cuff tears complain of pain, whereas others are asymptomatic. Previous studies have pointed out the presence of active bone metabolism in the painful shoulder, identified with increased radioisotope uptake during bone scintigraphy. Shoulders with symptomatic rotator cuff tears will demonstrate higher radioisotope uptake than shoulders with asymptomatic tears with bone scintigraphy, reflecting active bone metabolism in symptomatic tears. Cross-sectional study; Level of evidence, 3. The study consisted of 3 groups: patients with symptomatic tears (symptomatic group), patients with asymptomatic tears (asymptomatic group), and controls (no tear group). The symptomatic group consisted of 28 shoulders from 28 patients with symptomatic rotator cuff tears (pain score ≤4 on the University of California, Los Angeles [UCLA] shoulder evaluation form) who underwent bone scintigraphy followed by rotator cuff repair. Of 70 volunteers who had previously undergone bone scintigraphy for diseases unrelated to their shoulder, 34 were selected for the asymptomatic group (pain score ≥8 on the UCLA shoulder form), and 32 were selected for the no tear group. The mean radioisotope uptake in the symptomatic group was significantly higher than that in the asymptomatic group (P = .02) and the no tear group (P = .02). Ten of 28 shoulders (36%) in the symptomatic group showed increased radioisotope uptake exceeding 2 standard deviations from the mean of the no tear group. This percentage was significantly higher when compared with the asymptomatic group (0%) (P < .01). Shoulders with a symptomatic rotator cuff tear showed higher radioisotope uptake on bone scintigraphy than those with an asymptomatic tear. The radioisotope uptake in shoulders with an asymptomatic tear was comparable with that in shoulders without a tear. Positive radioisotope uptake may be associated with pain in a subgroup of patients with rotator cuff tears.
Divalent cations in tears, and their influence on tear film stability in humans and rabbits.
Wei, Xiaojia Eric; Markoulli, Maria; Millar, Thomas J; Willcox, Mark D P; Zhao, Zhenjun
2012-06-05
Reduced tear film stability is reported to contribute to dry eye. Rabbits are known to have a more stable tear film than humans. Thus, we sought to examine the tears of rabbits and humans for metal cations, and to test how they influence tear film stability. Tears were collected from 10 healthy humans and 6 rabbits. Tear osmolality was measured by vapor pressure osmometer, and metals analyzed using inductively coupled plasma (ICP) mass spectrometry or ICP atomic emission spectroscopy. The influence of divalent cations on tears was analyzed by measuring surface tension using the Langmuir trough in vitro, using different concentrations of cations in the subphase, and grading the tear break-up in rabbits in vivo after instillation of chelating agents. Rabbit tears had a higher osmolality compared to humans. Major metals did not differ between species; however, rabbits had higher levels of Mg(2+) (1.13 vs. 0.39 mM) and Ca(2+) (0.75 vs. 0.36 mM). In rabbit tears in vitro, diminishing divalent cations resulted in a decrease in the maximum surface pressure from 37 to 30 mN/m. In vivo, an increase in the amount of tear film that was broken-up was found. In contrast, when changing divalent cation concentrations in human tears, the maximum surface pressure remained at 26 mN/m. The normal osmolality of rabbit tears is significantly higher than that in humans. While divalent cations had little influence on human tears, they appear to have an important role in maintaining tear film stability in rabbits.
Increasing age and tear size reduce rotator cuff repair healing rate at 1 year.
Rashid, Mustafa S; Cooper, Cushla; Cook, Jonathan; Cooper, David; Dakin, Stephanie G; Snelling, Sarah; Carr, Andrew J
2017-12-01
Background and purpose - There is a need to understand the reasons why a high proportion of rotator cuff repairs fail to heal. Using data from a large randomized clinical trial, we evaluated age and tear size as risk factors for failure of rotator cuff repair. Patients and methods - Between 2007 and 2014, 65 surgeons from 47 hospitals in the National Health Service (NHS) recruited 447 patients with atraumatic rotator cuff tendon tears to the United Kingdom Rotator Cuff Trial (UKUFF) and 256 underwent rotator cuff repair. Cuff integrity was assessed by imaging in 217 patients, at 12 months post-operation. Logistic regression analysis was used to determine the influence of age and intra-operative tear size on healing. Hand dominance, sex, and previous steroid injections were controlled for. Results - The overall healing rate was 122/217 (56%) at 12 months. Healing rate decreased with increasing tear size (small tears 66%, medium tears 68%, large tears 47%, and massive tears 27% healed). The mean age of patients with a healed repair was 61 years compared with 64 years for those with a non-healed repair. Mean age increased with larger tear sizes (small tears 59 years, medium tears 62 years, large tears 64 years, and massive tears 66 years). Increasing age was an independent factor that negatively influenced healing, even after controlling for tear size. Only massive tears were an independent predictor of non-healing, after controlling for age. Interpretation - Although increasing age and larger tear size are both risks for failure of rotator cuff repair healing, age is the dominant risk factor.
Yoshida, Masahito; Collin, Phillipe; Josseaume, Thierry; Lädermann, Alexandre; Goto, Hideyuki; Sugimoto, Katumasa; Otsuka, Takanobu
2018-01-01
Magnetic resonance (MR) imaging is common in structural and qualitative assessment of the rotator cuff post-operatively. Rotator cuff integrity has been thought to be associated with clinical outcome. The purpose of this study was to evaluate the inter-observer reliability of cuff integrity (Sugaya's classification) and assess the correlation between Sugaya's classification and the clinical outcome. It was hypothesized that Sugaya's classification would show good reliability and good correlation with the clinical outcome. Post-operative MR images were taken two years post-operatively, following arthroscopic rotator cuff repair. For assessment of inter-rater reliability, all radiographic evaluations for the supraspinatus muscle were done by two orthopaedic surgeons and one radiologist. Rotator cuff integrity was classified into five categories, according to Sugaya's classification. Fatty infiltration was graded into four categories, based on the Fuchs' classification grading system. Muscle hypotrophy was graded as four grades, according to the scale proposed by Warner. The clinical outcome was assessed according to the constant scoring system pre-operatively and 2 years post-operatively. Of the sixty-two consecutive patients with full-thickness rotator cuff tears, fifty-two patients were reviewed in this study. These subjects included twenty-three men and twenty-nine women, with an average age of fifty-seven years. In terms of the inter-rater reliability between orthopaedic surgeons, Sugaya's classification showed the highest agreement [ICC (2.1) = 0.82] for rotator cuff integrity. The grade of fatty infiltration and muscle atrophy demonstrated good agreement, respectively (0.722 and 0.758). With regard to the inter-rater reliability between orthopaedic surgeon and radiologist, Sugaya's classification showed good reliability [ICC (2.1) = 0.70]. On the other hand, fatty infiltration and muscle hypotrophy classifications demonstrated fair and moderate agreement [ICC (2.1) = 0.39 and 0.49]. Although no significant correlation was found between overall post-operative constant score and Sugaya's classification, Sugaya's classification indicated significant correlation with the muscle strength score. Sugaya's classification showed repeatability and good agreement between the orthopaedist and radiologist, who are involved in the patient care for the rotator cuff tear. Common classification of rotator cuff integrity with good reliability will give appropriate information for clinicians to improve the patient care of the rotator cuff tear. This classification also would be helpful to predict the strength of arm abduction in the scapular plane. IV.
Eissa, Iman M; Khalil, Noha M; El-Gendy, Heba A
2016-01-01
Purpose. To assess the tear film quantity and correlate it with the quality and stability of the tear film in diabetics and compare them to age matched controls. Introduction. Diabetes affects tear film parameters in multiple ways. Poor metabolic control and neuropathy are postulated factors. To further understand how diabetes affects tear film parameters this study was conducted. Subjects and Methods. Tear meniscus height was measured by anterior segment OCT, along with tear thinning time, a subtype of noninvasive tear break-up time, and blinking rate per minute which were all recorded for 22 diabetic patients. Correlations between these tear film parameters were studied and then compared to 16 age matched controls. Results. A statistically significant difference was found in blinking rate between the diabetic and the control group (P = 0.002), with higher blinking rate among diabetics. All tear film parameters were negatively correlated with duration of diabetes. A positive correlation was found between tear film volume and stability. Conclusion. Diabetes affects the tear film in various ways. Diabetics should be examined for dry eye signs even in absence of symptoms which may be masked by associated neuropathy. Duration of diabetes has an impact on tear film status.
Goldmann tonometry tear film error and partial correction with a shaped applanation surface.
McCafferty, Sean J; Enikov, Eniko T; Schwiegerling, Jim; Ashley, Sean M
2018-01-01
The aim of the study was to quantify the isolated tear film adhesion error in a Goldmann applanation tonometer (GAT) prism and in a correcting applanation tonometry surface (CATS) prism. The separation force of a tonometer prism adhered by a tear film to a simulated cornea was measured to quantify an isolated tear film adhesion force. Acrylic hemispheres (7.8 mm radius) used as corneas were lathed over the apical 3.06 mm diameter to simulate full applanation contact with the prism surface for both GAT and CATS prisms. Tear film separation measurements were completed with both an artificial tear and fluorescein solutions as a fluid bridge. The applanation mire thicknesses were measured and correlated with the tear film separation measurements. Human cadaver eyes were used to validate simulated cornea tear film separation measurement differences between the GAT and CATS prisms. The CATS prism tear film adhesion error (2.74±0.21 mmHg) was significantly less than the GAT prism (4.57±0.18 mmHg, p <0.001). Tear film adhesion error was independent of applanation mire thickness ( R 2 =0.09, p =0.04). Fluorescein produces more tear film error than artificial tears (+0.51±0.04 mmHg; p <0.001). Cadaver eye validation indicated the CATS prism's tear film adhesion error (1.40±0.51 mmHg) was significantly less than that of the GAT prism (3.30±0.38 mmHg; p =0.002). Measured GAT tear film adhesion error is more than previously predicted. A CATS prism significantly reduced tear film adhesion error bŷ41%. Fluorescein solution increases the tear film adhesion compared to artificial tears, while mire thickness has a negligible effect.
Takahashi, N; Sugaya, H; Matsuki, K; Miyauchi, H; Matsumoto, M; Tokai, M; Onishi, K; Hoshika, S; Ueda, Y
2017-06-01
The aim of this study was to assess hypertrophy of the extra-articular tendon of the long head of biceps (LHB) in patients with a rotator cuff tear. The study involved 638 shoulders in 334 patients (175 men, 159 women, mean age 62.6 years; 25 to 81) with unilateral symptomatic rotator cuff tears. The cross-sectional area (CSA) of the LHB tendon in the bicipital groove was measured pre-operatively in both shoulders using ultrasound. There were 154 asymptomatic rotator cuff tears in the contralateral shoulder. Comparisons were made between those with a symptomatic tear, an asymptomatic tear and those with no rotator cuff tear. In the affected shoulders, the CSAs were compared in relation to the location and size of the rotator cuff tear. The mean CSA was 21.0 mm 2 (4 to 71) in those with a symptomatic rotator cuff tear, 19.9 mm 2 (4 to 75) in those with an asymptomatic rotator cuff tear and 14.1 mm 2 (5 to 43) in those with no rotator cuff tear. The mean CSA in patients with both symptomatic and asymptomatic rotator cuff tears was significantly larger than in those with no rotator cuff tear (p < 0.001). In the affected shoulders, there were significant differences between patients with more than a medium sized posterosuperior cuff tear and those with an antero-superior cuff tear. Regardless of the symptoms, there was significant hypertrophy of the extra-articular LHB tendon in patients with a rotator cuff tear. The values were significantly related to the size of the tear. Cite this article: Bone Joint J 2017;99-B:806-11. ©2017 The British Editorial Society of Bone & Joint Surgery.
Increasing age and tear size reduce rotator cuff repair healing rate at 1 year
Rashid, Mustafa S; Cooper, Cushla; Cook, Jonathan; Cooper, David; Dakin, Stephanie G; Snelling, Sarah; Carr, Andrew J
2017-01-01
Background and purpose — There is a need to understand the reasons why a high proportion of rotator cuff repairs fail to heal. Using data from a large randomized clinical trial, we evaluated age and tear size as risk factors for failure of rotator cuff repair. Patients and methods — Between 2007 and 2014, 65 surgeons from 47 hospitals in the National Health Service (NHS) recruited 447 patients with atraumatic rotator cuff tendon tears to the United Kingdom Rotator Cuff Trial (UKUFF) and 256 underwent rotator cuff repair. Cuff integrity was assessed by imaging in 217 patients, at 12 months post-operation. Logistic regression analysis was used to determine the influence of age and intra-operative tear size on healing. Hand dominance, sex, and previous steroid injections were controlled for. Results — The overall healing rate was 122/217 (56%) at 12 months. Healing rate decreased with increasing tear size (small tears 66%, medium tears 68%, large tears 47%, and massive tears 27% healed). The mean age of patients with a healed repair was 61 years compared with 64 years for those with a non-healed repair. Mean age increased with larger tear sizes (small tears 59 years, medium tears 62 years, large tears 64 years, and massive tears 66 years). Increasing age was an independent factor that negatively influenced healing, even after controlling for tear size. Only massive tears were an independent predictor of non-healing, after controlling for age. Interpretation — Although increasing age and larger tear size are both risks for failure of rotator cuff repair healing, age is the dominant risk factor. PMID:28880113
Potential Market for New Meniscus Repair Strategies: Evaluation of the MOON Cohort
Fetzer, Gary B.; Spindler, Kurt P.; Amendola, Annunziato; Andrish, Jack T.; Bergfeld, John A.; Dunn, Warren R.; Flanigan, David C.; Jones, Morgan; Kaeding, Christopher C.; Marx, Robert G.; Matava, Matthew J.; McCarty, Eric C.; Parker, Richard D.; Wolcott, Michelle; Vidal, Armando; Wolf, Brian R.; Wright, Rick W.
2013-01-01
Background An estimated 200,000 ACL reconstructions are performed each year in the United States. The presence of concomitant meniscus tears and subsequent treatment at the time of ACL reconstruction may determine long-term outcomes of these knees. The authors contend that a substantial number of these meniscal tears are treated in a fashion that reduces meniscal function and that new technologies are needed to treat meniscal tears in a fashion that preserves function. A large cohort of patients with meniscal tears is needed to demonstrate this need. The purpose of this study is to determine the incidence of meniscal tears, describe tear morphology, and selected treatment in the MOON prospective longitudinal cohort of ACL reconstruction. We also will demonstrate based on national statistics the large potential market that exists for future tissue engineering aimed at preserving meniscal function. Methods A multicenter cohort of 1014 patients undergoing ACL reconstruction between January 2002 and December 2003 were evaluated. All procedures were performed by nine fellowship trained sports medicine orthopaedic surgeons. Data on patient demographics, presence of a meniscus tear at time of ACL reconstruction, tear morphology, and meniscal treatment were collected prospectively. Meniscal tears were categorized into three potential tissue engineering treatment strategies: all-biologic repair, advanced repair, and scaffold replacement. Results 1014 ACL reconstructions were performed over the two year period. The median age at the time of surgery was 24 years. Thirty-six percent of the knees had medial meniscal tears and 44% of the knees had lateral meniscal tears. Longitudinal tears were the most common tear morphology. The most frequent treatment modality was partial meniscectomy (60%). Thirty percent of medial meniscal tears and 10% of lateral meniscal tears could be treated with all-biologic repair, 32% of medial meniscal tears and 28% of lateral meniscal tears could be treated with an advanced repair technique, and 35% of medial meniscal tears and 62% of lateral meniscal tears could be treated with scaffold replacement. Conclusions Although meniscal preservation is a generally accepted concept in the treatment of meniscal tears, the majority of tears in this young cohort undergoing ACL reconstruction were either not repairable types (radial) and/or in the avascular zone. Even with contemporary approaches to meniscal tear repair, we found significant limitations faced by the treating surgeon. The majority of tears in this population are currently treated by partial meniscectomy. The results of this cohort will hopefully, stimulate and focus future research and development of new tissue engineering strategies for a large potential market for meniscal function in an ACL reconstructed cohort. PMID:19634719
Nguyen, Caroline Tram; Chambers, Mark S; Powers, John M; Kiat-Amnuay, Sudarat
2013-06-01
There are reports of dissatisfaction with color instability and reduced lifetime of extraoral maxillofacial prostheses. Previous studies showed that UV mineral-based light-protecting agent (LP) improved color stability of MDX4-4210/Type A silicone elastomer. However, effects of this agent and opacifiers on mechanical properties of the elastomer are unknown. The purpose of this study was to evaluate the effect of 2 commonly used opacifiers and LP, a new opacifier, when combined with pigments on the mechanical properties of MDX4-4210/Type A silicone elastomer before and after artificial aging. Two commonly used opacifiers, titanium white dry pigment (TW) and silicone intrinsic white (SW) and LP were each combined with MDX4-4210/type A. Artists' oil pigment was then combined with the LP and TW groups, and silicone intrinsic pigments were combined with the SW group with 5 colors (no pigment=control, red, yellow, blue, or a combination of the 3 pigments). Ten dumbbell-shaped and 10 trouser-shaped specimens of each opacifier + pigment mixture, plus a control group with no opacifier and no pigment, were made for a total of 320 specimens. Half of the specimens (n=5) were aged in a chamber at 450 kJ/m(2). Specimens were tested for hardness (ASTM D2240), tensile strength (ASTM D412), tear strength (ASTM D624), and percentage elongation in a universal testing machine. A 3-way ANOVA and the Fisher PLSD test were performed (α=.05) for each mechanical property. After accelerated aging, values of Shore A hardness were the lowest for LP with all 5 pigments and the control, followed by SW and TW (P<.001). After accelerated aging, tear strength, tensile strength, and elongation decreased significantly (P<.001) for LP, whereas changes for SW and TW varied depending on the pigment. The mechanical properties of specimens with the light-protecting opacifier were adversely affected after being subjected to artificial aging. SW and TW preserved the mechanical properties of silicone in this study. Copyright © 2013 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.
The prevalence of rotator cuff tears: is the contralateral shoulder at risk?
Liem, Dennis; Buschmann, Vera Elisa; Schmidt, Carolin; Gosheger, Georg; Vogler, Tim; Schulte, Tobias L; Balke, Maurice
2014-04-01
Rotator cuff tears are a common cause of pain and disability of the shoulder. Information on the prevalence and identification of potential risk factors could help in early detection of rotator cuff tears and improve treatment outcome. Patients treated for a symptomatic rotator cuff tear on one side have a higher prevalence of rotator cuff tears and decreased shoulder function on the contralateral side compared with an age- and sex-matched group of healthy individuals. Case control study; Level of evidence, 3. One group consisted of 55 patients who had been arthroscopically treated on one shoulder for rotator cuff tear (tear group). In this group, the nonoperated contralateral shoulder was examined. For comparison, the matching shoulder in a control group consisting of 55 subjectively healthy individuals matched by age (±1 year) and sex to the tear group was included. Diagnosis of a rotator cuff tear was made by ultrasound. Outcomes were measured using the Constant score. The prevalence of supraspinatus tears was significantly higher (P < .0001) in the tear group (67.3%) compared with the control group (11.0%). The Constant score for the activities of daily living subscale, however, was significantly lower (18.4) in the tear group compared with the control group (19.9; P = .012). No other subcategory score nor the overall score showed a significant difference. There was a significantly higher tear prevalence in the tear group of patients aged between 50 and 59 years (P < .001) and 60 and 69 years (P = .004). No tear was diagnosed in the control group in individuals younger than 60 years. Patients treated for partial and full-thickness rotator cuff tears have a significantly higher risk of having a tear on the contralateral side and have noticeable deficits in their shoulder function regarding activities of daily living even if the tear is otherwise asymptomatic.
Park, Do Young; Min, Byoung-Hyun; Choi, Byung Hyune; Kim, Young Jick; Kim, Mijin; Suh-Kim, Haeyoung; Kim, Joon Ho
2015-12-01
Fibrocartilage metaplasia in tendons and ligaments is an adaptation to compression as well as a pathological feature during degeneration. Medial meniscus posterior roots are unique ligaments that resist multidirectional forces, including compression. To characterize the degeneration of medial meniscus posterior root tears in osteoarthritic knees, with an emphasis on fibrocartilage and calcification. Cross-sectional study; Level of evidence, 3. Samples of medial meniscus posterior roots were harvested from cadaveric specimens and patients during knee replacement surgery and grouped as follows: normal reference, no tear, partial tear, and complete tear. Degeneration was analyzed with histology, immunohistochemistry, and real-time polymerase chain reaction. Uniaxial tensile tests were performed on specimens with and without fibrocartilage. Quantifiable data were statistically analyzed by the Kruskal-Wallis test with the Dunn comparison test. Thirty, 28, and 42 samples harvested from 99 patients were allocated into the no tear, partial tear, and complete tear groups, respectively. Mean modified Bonar tendinopathy scores for each group were 3.97, 9.31, and 14.15, respectively, showing a higher degree of degeneration associated with the extent of the tear (P < .05 for all groups). The characterization of root matrices revealed an increase in fibrocartilage according to the extent of the tear. Tear margins revealed fibrocartilage in 59.3% of partial tear samples and 76.2% of complete tear samples, with a distinctive cleavage-like shape. Root tears with a similar shape were induced within fibrocartilaginous areas during uniaxial tensile testing. Even in the no tear group, 56.7% of samples showed fibrocartilage in the anterior margin of the root, adjacent to the meniscus. An increased stained area of calcification and expression of the ectonucleotide pyrophosphatase/phosphodiesterase 1 gene were observed in the complete tear group compared with the no tear group (P < .0001 and P = .24, respectively). Fibrocartilage and calcification increased in medial meniscus posterior roots, associated with the degree of the tear. Both findings, which impair the ligament's resistance to tension, may play a pivotal role during the pathogenesis of degenerative meniscus root tears in osteoarthritic knees. Fibrocartilage and calcification may be useful as diagnostic markers as well as markers of degeneration, which may aid in determining the treatment modality in meniscus root tears. The presence of fibrocartilage in intact roots may suggest an impending tear in osteoarthritic knees. © 2015 The Author(s).
Dhasmana, Renu; Nagpal, Ramesh Chander
2016-01-01
Introduction Dry eye is one of the most common ocular diseases in this cyber era. Despite availability of multiple tests, no single test is accurate for the diagnosis of dry eye. Anterior segment optical coherence tomography is the recent tool which can be added in the armentarium of dry eye tests. Aim To evaluate tear meniscus with anterior segment optical coherence tomography and its correlation with other tear variables in normal healthy individuals. Materials and Methods In this prospective cross-sectional observational study, right eye of 203 consecutive patients were studied. All the patients were divided into three groups Group 1, 2 and 3 according to their age ≤20 years, 21-40 years and >40 years respectively. All patients underwent routine ophthalmologic examinations along with slit-lamp bio-microscopy for tear meniscus height measurement, tear film break up time, Schirmer’s I test (with anaesthesia) and optical coherence tomography imaging of inferior tear meniscus height. After focusing of the instrument with a Cross Line (CL) centered on lower tear meniscus at 6’0 clock of cornea, a 6 mm long scan was obtained. The tear meniscus height (μm) and tear meniscus area (mm2) were measured manually with help of callipers by joining upper corneo-meniscus junction to the lower lid-meniscus junction and tear meniscus height and area within the plotted line respectively and calculated by using the integrated analysis available in the custom software. Results There was significant decrease in the all tear variables with the increase in the age. According to age groups in group 1, the mean Schirmer’s (24.0±4.9)mm, tear film break up time (11.1±1.9) sec, tear meniscus height on slit lamp (600.2±167.3)mm were higher but decreased in group 2 (21.5±5.4,10.8±1.4, 597.5±186.3) and group 3 (19.8 ± 5.1, 10.2 ± 1.6, 485.6 ± 157.7) respectively. Schirmer’s test values and tear film break up time were similar in both sexes (p=0.1 and p= 0.9). Tear meniscus height on slit lamp and Optical coherence based tear meniscus area were similar in both sexes (p=0.5 and p=0.1). However, tear meniscus height on optical coherence tomography was significantly higher in females (p=0.04). Value of Schirmer’s and tear film break up time (r =0.2; p= 0.001) and Schirmer’s and tear meniscus height on slit lamp (r=0.6; p<0.001) had positive correlation. Tear meniscus height and tear meniscus area on optical coherence tomography had positive correlation (r =.9; p<0.001). Conclusion On optical coherence tomography tear meniscus height and area significantly correlated. Despite higher values of Schirmer’s, tear film break up time, Slit lamp based tear meniscus height in younger age group the tear meniscus height and tear meniscus area with optical coherence tomography were lower. PMID:27437253
TFOS DEWS II Tear Film Report.
Willcox, Mark D P; Argüeso, Pablo; Georgiev, Georgi A; Holopainen, Juha M; Laurie, Gordon W; Millar, Tom J; Papas, Eric B; Rolland, Jannick P; Schmidt, Tannin A; Stahl, Ulrike; Suarez, Tatiana; Subbaraman, Lakshman N; Uçakhan, Omür Ö; Jones, Lyndon
2017-07-01
The members of the Tear Film Subcommittee reviewed the role of the tear film in dry eye disease (DED). The Subcommittee reviewed biophysical and biochemical aspects of tears and how these change in DED. Clinically, DED is characterized by loss of tear volume, more rapid breakup of the tear film and increased evaporation of tears from the ocular surface. The tear film is composed of many substances including lipids, proteins, mucins and electrolytes. All of these contribute to the integrity of the tear film but exactly how they interact is still an area of active research. Tear film osmolarity increases in DED. Changes to other components such as proteins and mucins can be used as biomarkers for DED. The Subcommittee recommended areas for future research to advance our understanding of the tear film and how this changes with DED. The final report was written after review by all Subcommittee members and the entire TFOS DEWS II membership. Copyright © 2017 Elsevier Inc. All rights reserved.
The brilliant beauty of the eye: light reflex from the cornea and tear film.
Goto, Eiki
2006-12-01
Light reflex from the cornea and tear film as contributors to beautiful eyes ("eye sparkling") are reviewed. A systematic literature review was conducted using "Purkinje-Sanson image," "corneal light reflex," "corneal topography," "corneal wavefront aberration," and "tear interference image" as search terms. Articles on corneal surface regularity and stability and tear interferometry of the precorneal tear lipid layer were reviewed. PS-1 image, that is light reflex from the cornea and tear film, is widely used in practical ophthalmic examination. To achieve a brilliant beauty of the eye ("eye sparkling"), it is important that the tear film (aqueous layer) surface is smooth and stable with adequate tear volume and that the tear lipid layer is present in adequate thickness.
Patel, Roshni; Zhu, Meifang; Robertson, Danielle M
2018-06-01
The human corneal epithelium expresses both the insulin-like growth factor type 1 receptor (IGF-1R) and the IGF-1R/insulin receptor (INSR) hybrid. Despite the previous identification of IGF-1 in human tear fluid, little is known regarding the regulation of IGF-1 in tear fluid and its role in corneal epithelial homeostasis. In the present study, we investigated the impact of biological parameters on the concentration of human tear levels of IGF-1. Tear levels of IGF-1 were measured in 41 healthy, human volunteers without any reported symptoms of dry eye. All volunteers underwent standard biomicroscopic examination of the cornea and tear film. In a subgroup of volunteers, corneal staining with sodium fluorescein, tear film break up time and tear production using a Schirmer's test strip were measured to assess clinical signs of dry eye. Tears were collected from the inferior tear meniscus using glass microcapillary tubes and IGF-1 levels were measured using a solid phase sandwich ELISA. Tear levels of IGF-1 were highest in young adults and significantly decreased in older adults (P = 0.003). There were no differences in tear IGF-1 between males and females (P = 0.628). Tear IGF-1 levels were correlated with tear film break up time (R = 0.738) and tear production (R = 0.826). These data indicate that there is a progressive decline in tear IGF-1 due to aging that is associated with clinical signs of dry eye. This effect is likely due to age-related changes in the lacrimal gland. Copyright © 2018 Elsevier Ltd. All rights reserved.
Chung, Michael; Radacsi, Norbert; Robert, Colin; McCarthy, Edward D; Callanan, Anthony; Conlisk, Noel; Hoskins, Peter R; Koutsos, Vasileios
2018-01-01
There is a potential for direct model manufacturing of abdominal aortic aneurysm (AAA) using 3D printing technique for generating flexible semi-transparent prototypes. A patient-specific AAA model was manufactured using fused deposition modelling (FDM) 3D printing technology. A flexible, semi-transparent thermoplastic polyurethane (TPU), called Cheetah Water (produced by Ninjatek, USA), was used as the flexible, transparent material for model manufacture with a hydrophilic support structure 3D printed with polyvinyl alcohol (PVA). Printing parameters were investigated to evaluate their effect on 3D-printing precision and transparency of the final model. ISO standard tear resistance tests were carried out on Ninjatek Cheetah specimens for a comparison of tear strength with silicone rubbers. It was found that an increase in printing speed decreased printing accuracy, whilst using an infill percentage of 100% and printing nozzle temperature of 255 °C produced the most transparent results. The model had fair transparency, allowing external inspection of model inserts such as stent grafts, and good flexibility with an overall discrepancy between CAD and physical model average wall thicknesses of 0.05 mm (2.5% thicker than the CAD model). The tear resistance test found Ninjatek Cheetah TPU to have an average tear resistance of 83 kN/m, higher than any of the silicone rubbers used in previous AAA model manufacture. The model had lower cost (4.50 GBP per model), shorter manufacturing time (25 h 3 min) and an acceptable level of accuracy (2.61% error) compared to other methods. It was concluded that the model would be of use in endovascular aneurysm repair planning and education, particularly for practicing placement of hooked or barbed stents, due to the model's balance of flexibility, transparency, robustness and cost-effectiveness.
Abrams, Geoffrey D; Gupta, Anil K; Hussey, Kristen E; Tetteh, Elizabeth S; Karas, Vasili; Bach, Bernard R; Cole, Brian J; Romeo, Anthony A; Verma, Nikhil N
2014-06-01
Acromioplasty is commonly performed during arthroscopic rotator cuff repair, but its effect on short-term outcomes is debated. To report the short-term clinical outcomes of patients undergoing arthroscopic repair of full-thickness rotator cuff tears with and without acromioplasty. Randomized controlled trial; Level of evidence, 2. Patients undergoing arthroscopic repair of full-thickness rotator cuff tears were randomized into acromioplasty or nonacromioplasty groups. The Simple Shoulder Test (SST), American Shoulder and Elbow Surgeons (ASES) score, Constant score, University of California-Los Angeles (UCLA) score, and Short Form-12 (SF-12) health assessment were collected along with physical examination including range of motion and dynamometer strength testing. Intraoperative data including tear size, repair configuration, and concomitant procedures were recorded. Follow-up examination was performed at regular intervals up to 2 years. Preoperative imaging was reviewed to classify the acromial morphologic type, acromial angle, and lateral acromial angulation. A total of 114 patients were initially enrolled in the study, and 95 (83%; 43 nonacromioplasty, 52 acromioplasty) were available for a minimum 2-year follow-up. There were no significant differences in baseline characteristics, including number of tendons torn, repair configuration, concomitant procedures, and acromion type and angles. Within groups, there was a significant (P < .001) improvement in all functional outcome scores from preoperatively to all follow-up time points, including 2 years, for the nonacromioplasty and acromioplasty groups (ASES score: 55.1-91.5, 48.8-89.0; Constant score: 48.3-75.0, 51.9-78.7, respectively). There were no significant differences in functional outcomes between nonacromioplasty and acromioplasty groups or between subjects with different acromial features at any time point. The results of this study demonstrate no difference in clinical outcomes after rotator cuff repair with or without acromioplasty at 2 years postoperatively. © 2014 The Author(s).
Detection of endogenous cortisol in equine tears and blood at rest and after simulated stress.
Monk, Caroline S; Hart, Kelsey A; Berghaus, Roy D; Norton, Natalie A; Moore, Phillip A; Myrna, Kathern E
2014-07-01
To determine whether cortisol is present in equine tears at rest and during simulated stress and compare tear cortisol to serum free and total cortisol. Fourteen healthy adult horses were included. Paired tear total cortisol and serum total and free cortisol concentrations were measured with ELISA, chemiluminescent immunoassay, and ultrafiltration methodology, respectively, in 10 horses at rest once daily for five consecutive days. In an additional four horses, paired tear and serum samples were collected for cortisol measurement before and after adrenocorticotropic hormone (ACTH) stimulation (cosyntropin, 1 μg/kg IV). Cortisol was detectable in equine tears at rest. Following ACTH stimulation, tear cortisol increased significantly from baseline at 60-120 min (P ≤ 0.001). Serum total and free cortisol also increased significantly at 30-180 min after ACTH stimulation (P ≤ 0.001). Both serum and tear cortisol returned to baseline concentrations by 360 min. Changes in tear cortisol were similarly associated with changes in serum total and free cortisol, although high tear cortisol concentrations suggest a portion of tear cortisol may be protein-bound. Cortisol is present in equine tears and increases in concert with serum cortisol following ACTH stimulation. Further study is needed to determine whether endogenous cortisol in tears contributes to ocular pathology. © 2013 American College of Veterinary Ophthalmologists.
A comparison of MRI findings in patients with acute and chronic ACL tears.
Dimond, P M; Fadale, P D; Hulstyn, M J; Tung, G A; Greisberg, J
1998-01-01
This retrospective study compared the magnetic resonance imaging (MRI) findings in 87 patients with acute and chronic anterior cruciate ligament (ACL) tears. Sixty patients had acute tears and 27 had chronic tears. The appearance of the torn ligament was examined on MRI, and associated meniscal and osteochondral injuries were described. All findings were verified at arthroscopy. Acute ACL tears (MRI examination was performed within 6 weeks of injury) were typified by the presence of diffuse (58%) or focal (42%) increased signal within the ligament, whereas chronic ACL tears (MRI examination was performed more than 6 months after injury) usually appeared as either a fragmented ligament (44%) or an intact band of low signal with abnormal orientation (30%). Patients with chronic ACL tears had a higher prevalence of medial meniscal tears (78% versus 40%), articular chondromalacia, and an increased posterior cruciate bow ratio (0.47 versus 0.37) in association with chronic ACL tears. A bone bruise was seen in 68% of acute ACL tears but in no case of chronic ACL tear. On MRI, there are salient differences between acute and chronic ACL tears. Chronic ACL tears are associated with a greater prevalence of meniscal and osteochondral injuries. These findings may have implications for future treatment recommendations.
Koh, Shizuka; Tung, Cynthia; Aquavella, James; Yadav, Rahul; Zavislan, James; Yoon, Geunyoung
2010-07-01
PURPOSE. To investigate tear film dynamics using simultaneous measurements of ocular aberrations and lower tear meniscus. METHODS. Simultaneous measurements of wavefront aberration and lower tear meniscus were performed for 11 normal eyes and 7 eyes with short tear film break-up time (SBUT) dry eye, with a tear film break-up time shorter than 5 seconds, using a wavefront sensor and an anterior segment optical coherence tomography (OCT). During the measurement, the subjects were instructed to blink every 6 seconds for a total of 30 seconds. From the measured aberration, root mean square (RMS) wavefront error and volume modulation transfer function (vMTF) induced by changes in tear film dynamics were calculated for a 5-mm pupil. Lower tear meniscus height (TMH) and area (TMA) were estimated from the cross-sectional OCT images of lower tear meniscus. RESULTS. There was a positive correlation between RMS and tear meniscus dimensions and a negative correlation between vMTF and tear meniscus in both groups. There were moderate negative correlations between the postblink initial RMS change and baseline TMH (R = -0.61) and TMA (R = -0.54) in SBUT dry eyes that were stronger than in normal eyes (R = -0.37, R = -0.38). CONCLUSIONS. Tear meniscus dimensions increase with RMS over time, and tear quantity before blink has a significant role in maintaining initial optical integrity, especially in SBUT dry eye. Simultaneous measurement of optical quality and tear meniscus has the potential to improve understanding of tear stability in normal eyes and dry eyes.
Mass Spectrometric Identification of Phospholipids in Human Tears and Tear Lipocalin
Dean, Austin W.; Glasgow, Ben J.
2012-01-01
Purpose. The purpose of this article was to identify by mass spectrometry phosphocholine lipids in stimulated human tears and determine the molecules bound to tear lipocalin or other proteins. Methods. Tear proteins were separated isocratically from pooled stimulated human tears by gel filtration fast performance liquid chromatography. Separation of tear lipocalin was confirmed by SDS tricine gradient PAGE. Protein fractions were extracted with chloroform/methanol and analyzed with electrospray ionization MS/MS triple quadrupole mass spectrometry in precursor ion scan mode for select leaving groups. For quantification, integrated ion counts were derived from standard curves of authentic compounds of phosphatidylcholine (PC) and phosphatidylserine. Results. Linear approximation was possible from integration of the mass spectrometrically obtained ion peaks at 760 Da for the PC standard. Tears contained 194 ng/mL of the major intact PC (34:2), m/z 758.6. Ten other monoisotopic phosphocholines were found in tears. A peak at 703.3 Da was assigned as a sphingomyelin. Four lysophosphatidylcholines (m/z 490–540) accounted for about 80% of the total integrated ion count. The [M+H]+ compound, m/z 496.3, accounted for 60% of the signal intensity. Only the tear lipocalin–bearing fractions showed phosphocholines (104 ng/mL). Although the intact phospholipids bound to tear lipocalin corresponded precisely in mass and relative signal intensity to that found in tears, we did not identify phosphocholines between m/z 490 and 540 in any of the gel-filtration fractions. Conclusions. Phospholipids, predominantly lysophospholipids, are present in tears. The higher mass intact PCs in tears are native ligands of tear lipocalin. PMID:22395887
Mass spectrometric identification of phospholipids in human tears and tear lipocalin.
Dean, Austin W; Glasgow, Ben J
2012-04-02
The purpose of this article was to identify by mass spectrometry phosphocholine lipids in stimulated human tears and determine the molecules bound to tear lipocalin or other proteins. Tear proteins were separated isocratically from pooled stimulated human tears by gel filtration fast performance liquid chromatography. Separation of tear lipocalin was confirmed by SDS tricine gradient PAGE. Protein fractions were extracted with chloroform/methanol and analyzed with electrospray ionization MS/MS triple quadrupole mass spectrometry in precursor ion scan mode for select leaving groups. For quantification, integrated ion counts were derived from standard curves of authentic compounds of phosphatidylcholine (PC) and phosphatidylserine. Linear approximation was possible from integration of the mass spectrometrically obtained ion peaks at 760 Da for the PC standard. Tears contained 194 ng/mL of the major intact PC (34:2), m/z 758.6. Ten other monoisotopic phosphocholines were found in tears. A peak at 703.3 Da was assigned as a sphingomyelin. Four lysophosphatidylcholines (m/z 490-540) accounted for about 80% of the total integrated ion count. The [M+H](+) compound, m/z 496.3, accounted for 60% of the signal intensity. Only the tear lipocalin-bearing fractions showed phosphocholines (104 ng/mL). Although the intact phospholipids bound to tear lipocalin corresponded precisely in mass and relative signal intensity to that found in tears, we did not identify phosphocholines between m/z 490 and 540 in any of the gel-filtration fractions. Phospholipids, predominantly lysophospholipids, are present in tears. The higher mass intact PCs in tears are native ligands of tear lipocalin.
Guyette, Nicole; Williams, Larezia; Tran, My-Tho; Than, Tammy; Bradley, John; Kehinde, Lucy; Edwards, Clara; Beasley, Mark; Fullard, Roderick
2013-05-01
Low tear volume limits the use of nonstimulated (NS) microcapillary tear collection in aqueous-deficient (AD) patients. Adding a small amount of "washout" fluid to the eye prior to tear collection is a potentially viable alternative method for abundant proteins, but is relatively untested for low-abundance biomarkers. This study determined the feasibility of the washout (WO) method as an NS alternative for low-abundance biomarkers. NS and WO biomarker profiles were compared between AD patients and non-AD controls to determine if the two methods identify the same intergroup differences. Matching NS and WO tears were collected from 48 patients by micropipette, the WO sample after instillation of 10 μL saline. Tear cytokine levels were measured by 27-Plex Bio-Rad assay. Bland-Altman analyses for each biomarker determined the agreement between tear sample types. Patients were grouped as AD or non-AD based on Schirmer score to determine if NS profile between-group differences were preserved in WO tears. Bland-Altman plots showed good biomarker level agreement between NS and WO tears for most cytokines. Five biomarkers, among those most often cited as differing in AD dry eye, differed significantly between non-AD and AD groups in both tear types. Additional biomarker differences were seen in NS tears only. The WO tear collection method is a viable alternative to NS tears for many low-abundance biomarkers and is able to replicate major NS tear differences between dry eye groups. More subtle intergroup differences are lost in WO samples because of reduced statistical power.
Diffusion of chaotic field lines in tokamaks
NASA Astrophysics Data System (ADS)
Ali, Halima; Punjabi, Alkesh
2006-10-01
An important instability for the destruction of magnetic surfaces in tokamaks due to island overlapping is the tearing modes. Magnetic fields perturbed by tearing modes are given by the sinusoidal form Br=-1rR∑m,nbm^n ( mθ-n ) . The sinusoidal nature of perturbation creates islands structure near resonant surfaces. In this work, we consider two modes, ( m1,n1 )and ( m2,n2 )that interact with each other, leading to two chains of islands, called primary islands. We use a previously derived Hamiltonian map, the ψ-θ map, with and without higher order control terms to study the diffusion of chaotic field lines. We will present and discuss the results of this work, and discuss its implications with regard to magnetic transport barriers for a fixed q-profile and increasing strength of magnetic perturbations. This work is done under the DOE grant number DE-FG02-01ER54624. 1.A. Punjabi et al, Phys. Rev. lett., 69, 3322 (1992). 2. H. Ali, A. Punjabi, and A. Boozer, Int. J. Comp. Num. Ana. Applications 6, 17 (2005).
Stem Cell Applications in Tendon Disorders: A Clinical Perspective
Young, Mark
2012-01-01
Tendon injuries are a common cause of morbidity and a significant health burden on society. Tendons are structural tissues connecting muscle to bone and are prone to tearing and tendinopathy, an overuse or degenerative condition that is characterized by failed healing and cellular depletion. Current treatments, for tendon tear are conservative, surgical repair or surgical scaffold reconstruction. Tendinopathy is treated by exercises, injection therapies, shock wave treatments or surgical tendon debridement. However, tendons usually heal with fibrosis and scar tissue, which has suboptimal tensile strength and is prone to reinjury, resulting in lifestyle changes with activity restriction. Preclinical studies show that cell therapies have the potential to regenerate rather than repair tendon tissue, a process termed tenogenesis. A number of different cell lines, with varying degrees of differentiation, have being evaluated including stem cells, tendon derived cells and dermal fibroblasts. Even though cellular therapies offer some potential in treating tendon disorders, there have been few published clinical trials to determine the ideal cell source, the number of cells to administer, or the optimal bioscaffold for clinical use. PMID:22448174
Non-contrast magnetic resonance imaging for diagnosing shoulder injuries.
Arnold, Heino
2012-12-01
To compare preoperative non-contrast magnetic resonance imaging (MRI) with arthroscopy findings in diagnosing labral and rotator cuff tears. 86 men and 60 women aged 21 to 70 (mean, 52) years underwent non-contrast MRI before arthroscopic operations on the glenohumeral joint. Slices were made in a transverse, parasagittal, and paracoronar orientation. The sequences used were T2- and proton-weighted for paracoronar imaging, T1- and T2-weighted for transverse and parasagittal imaging, and T2-weigthed sequences with fat suppression and short tau inversion recovery sequences. MRI was evaluated with the surgeon to eliminate interobserver bias. Arthroscopic surgery was performed by a single surgeon. If a labral or rotator cuff tear was found, surgery was performed using corkscrew anchors. For full thickness rotator cuff tears, MRI and arthroscopy detected them in 76 and 82 patients, respectively. One such tear found by MRI could not be confirmed by arthroscopy. MRI missed 4 subscapularis and 3 supraspinatus tears. The sensitivity and specificity of MRI in diagnosing full thickness rotator cuff tears were 0.90 and 0.91, respectively. For labral tears, MRI and arthroscopy detected them in 16 and 31 patients, respectively. One anterior labral tear detected by MRI could not be verified by arthroscopy. All 16 labral tears detected by MRI were Bankart type-I tears (of the anterior glenoid) except for one superior labral tear from anterior to posterior (SLAP tear). All 13 SLAP tears (10 type 2 and 3 type 3) except for one could be found by arthroscopy only. The sensitivity and specificity of MRI in diagnosing labral tears were 0.52 and 0.89, respectively. Non-contrast MRI is reliable only for diagnosing full thickness rotator cuff tears and anterior labral tears. Direct or indirect contrast enhancement is recommended for more differentiation. Special scan orientation is necessary for SLAP tears.
Tear-Film Evaporation Rate from Simultaneous Ocular-Surface Temperature and Tear-Breakup Area.
Dursch, Thomas J; Li, Wing; Taraz, Baseem; Lin, Meng C; Radke, Clayton J
2018-01-01
A corneal heat-transfer model is presented to quantify simultaneous measurements of fluorescein tear-breakup area (TBA) and ocular-surface temperature (OST). By accounting for disruption of the tear-film lipid layer (TFLL), we report evaporation rates through lipid-covered tear. The modified heat-transfer model provides new insights into evaporative dry eye. A quantitative analysis is presented to assess human aqueous tear evaporation rate (TER) through intact TFLLs from simultaneous in vivo measurement of time-dependent infrared OST and fluorescein TBA. We interpret simultaneous OST and TBA measurements using an extended heat-transfer model. We hypothesize that TBAs are ineffectively insulated by the TFLL and therefore exhibit higher TER than does that for a well-insulting TFLL-covered tear. As time proceeds, TBAs increase in number and size, thereby increasing the cornea area-averaged TER and decreasing OST. Tear-breakup areas were assessed from image analysis of fluorescein tear-film-breakup video recordings and are included in the heat-transfer description of OST. Model-predicted OSTs agree well with clinical experiments. Percent reductions in TER of lipid-covered tear range from 50 to 95% of that for pure water, in good agreement with literature. The physical picture of noninsulating or ruptured TFLL spots followed by enhanced evaporation from underlying cooler tear-film ruptures is consistent with the evaporative-driven mechanism for local tear rupture. A quantitative analysis is presented of in vivo TER from simultaneous clinical measurement of transient OST and TBA. The new heat-transfer model accounts for increased TER through expanding TBAs. Tear evaporation rate varies strongly across the cornea because lipid is effectively missing over tear-rupture troughs. The result is local faster evaporation compared with nonruptured, thick lipid-covered tear. Evaporative-driven tear-film ruptures deepen to a thickness where fluorescein quenching commences and local salinity rises to uncomfortable levels. Mitigation of tear-film rupture may therefore reduce dry eye-related symptoms.
Duchman, Kyle R.; Westermann, Robert W.; Spindler, Kurt P.; Reinke, Emily K.; Huston, Laura J.; Amendola, Annunziato; Wolf, Brian R.
2016-01-01
Background The management of meniscus tears identified at the time of primary ACL reconstruction is highly variable and includes repair, meniscectomy, and non-treatment. Hypothesis/Purpose The purpose of this study is to determine the reoperation rate for meniscus tears left untreated at the time of ACL reconstruction with minimum follow-up of 6 years. We hypothesize that small, peripheral tears identified at the time of ACL reconstruction managed with “no treatment” will have successful clinical outcomes. Study Design Retrospective study of a prospective cohort; Level of Evidence, 3 Methods Patients with meniscus tears left untreated at the time of primary ACL reconstruction were identified from a multicenter study group with minimum 6-year follow-up. Patient, tear, and reoperation data were obtained for analysis. Need for reoperation was used as the primary endpoint, with analysis performed to determine patient and tear characteristics associated with reoperation. Results There were 194 patients with 208 meniscus tears (71 medial; 137 lateral) left in situ without treatment with complete follow-up for analysis. Of these, 97.8% of lateral and 94.4% of medial untreated tears required no reoperation. Sixteen tears (7.7%) left in situ without treatment underwent subsequent reoperation: 9 tears (4.3%) underwent reoperation in the setting of revision ACL reconstruction and 7 tears (3.4%) underwent reoperation for isolated meniscus pathology. Patient age was significantly lower in patients requiring reoperation, while tears measuring ≥ 10 mm more frequently required reoperation. Conclusions Lateral and medial meniscus tears left in situ at the time of ACL reconstruction did not require reoperation at minimum 6-year follow-up for 97.8% and 94.4% of tears, respectively. These findings reemphasize the low reoperation rate following non-treatment of small, peripheral lateral meniscus tears while noting less predictable results for medial meniscus tears left without treatment. PMID:26430058
Posterior meniscus root tears: associated pathologies to assist as diagnostic tools.
Matheny, Lauren M; Ockuly, Andrew C; Steadman, J Richard; LaPrade, Robert F
2015-10-01
The purpose of this study was to investigate associated pathologies identified at arthroscopy in patients with meniscus root tears. This study was Institutional Review Board approved. All patients who underwent arthroscopic knee surgery where a complete meniscus root tear was identified were included in this study. Concurrent ligament tears and articular cartilage changes ≥Outerbridge grade 2 were recorded and stored in a data registry. Fifty patients (28 males, 22 females) [mean age = 36.5 years (range 17.1-68.1 years)] who were diagnosed with a medial or lateral meniscus root tear at arthroscopy were included in this study out of 673 arthroscopic surgeries (prevalence 7.4 %). Twenty-three (46 %) patients had a medial meniscus root tear, 26 (52 %) patients had a lateral meniscus root tear and one (2 %) patient had both. Thirty-four per cent of patients (n = 17) underwent partial meniscectomy, while 60 % (n = 31) underwent suture repair. During arthroscopy, 60 % (n = 30) of patients were diagnosed with an anterior cruciate ligament (ACL) tear. Patients with lateral meniscus root tears were 10.3 times (95 % CI 2.6-42.5) more likely to have ACL tears than patients with medial meniscus root tears (p = 0.012). Patients who had medial meniscus root tears were 5.8 times (95 % CI 1.6-20.5) more likely to have chondral defects than patients who had lateral meniscus root tears (p = 0.044). In this study, patients' preoperative functional scores and activity levels were low. Patients with lateral meniscal root tears were more likely to have an ACL tear. Patients with medial meniscal root tears were more likely to have an knee articular cartilage defect with an Outerbridge grade 2 or higher chondral defect. This study confirms the importance of comprehensive assessment of concurrent injuries to properly diagnose meniscus root tears. IV.
Duchman, Kyle R; Westermann, Robert W; Spindler, Kurt P; Reinke, Emily K; Huston, Laura J; Amendola, Annunziato; Wolf, Brian R
2015-11-01
The management of meniscus tears identified at the time of primary anterior cruciate ligament (ACL) reconstruction is highly variable and includes repair, meniscectomy, and nontreatment. The purpose of this study was to determine the reoperation rate for meniscus tears left untreated at the time of ACL reconstruction with a minimum follow-up of 6 years. The hypothesis was that small peripheral tears identified at the time of ACL reconstruction managed with "no treatment" would have successful clinical outcomes. Cohort study; Level of evidence, 3. Patients with meniscus tears left untreated at the time of primary ACL reconstruction were identified from a multicenter study group with a minimum 6-year follow-up. Patient, tear, and reoperation data were obtained for analysis. The need for reoperation was used as the primary endpoint, with analysis performed to determine patient and tear characteristics associated with reoperation. There were 194 patients with 208 meniscus tears (71 medial, 137 lateral) left in situ without treatment with a complete follow-up for analysis. Of these, 97.8% of lateral and 94.4% of medial untreated tears required no reoperation. Sixteen tears (7.7%) left in situ without treatment underwent subsequent reoperation: 9 tears (4.3%) underwent reoperation in the setting of revision ACL reconstruction, and 7 tears (3.4%) underwent reoperation for an isolated meniscus injury. The patient age was significantly lower in patients requiring reoperation, while tears measuring ≥10 mm more frequently required reoperation. Lateral and medial meniscus tears left in situ at the time of ACL reconstruction did not require reoperation at a minimum 6-year follow-up for 97.8% and 94.4% of tears, respectively. These findings re-emphasize the low reoperation rate after the nontreatment of small, peripheral lateral meniscus tears while noting less predictable results for medial meniscus tears left without treatment. © 2015 The Author(s).
Tear Film Osmolarity in Subjects with Acute Allergic Rhinoconjunctivitis
NITODA, EIRINI; LAVARIS, ANASTASIOS; LAIOS, KONSTANTINOS; ANDROUDI, SOPHIA; KALOGEROPOULOS, CHRIS D; TSATSOS, MICHAEL; DAMASKOS, CHRISTOS; GARMPIS, NIKOLAOS; MOSCHOS, MARILITA M
2018-01-01
Background/Aim: Acute allergic rhinoconjuctivitis is the most common form of ocular allergies. The pathogenetic mechanisms are based on an immunoglobulin E (IgE)-mediated hypersensitivity reaction. On the other hand, tear osmolarity has been suggested to be an index of ocular surface damage and inflammation. These data were the motive to investigate the levels of tear osmolarity in subjects with acute allergic rhinoconjuctivitis, before and after administration of artificial tears. Patients and Methods: Forty-five subjects with acute allergic rhinoconjuctivitis were randomly divided into three groups, based on the type of artificial tears that they received: Group A (Thera tears), Group B (Wet therapy) and Group C (Tears Naturale free). The eye drops were administered six times a day for 60 days and all subjects underwent grading of subjective symptoms and clinical examination at baseline and at the end of the treatment. Results: The diagnosis of severe eye disease, which was based on ocular surface disease index (OSDI; Allergan, Inc, Irvine, CA, USA) and tear osmolarity values, concerned all patients at baseline. Although the administration of artificial tears significantly ameliorated the symptoms and the ocular variables in all groups, the results were better in the first group. Tear osmolarity was strongly and negatively correlated with tear film breakup time (BUT) and Schirmer I test at 2 months. Contrariwise, symptoms were eliminated, when tear osmolarity was decreased. Conclusion: Acute allergic rhinoconjuctivitis is characterized by tear hyperosmolarity, which can be rehabilitated with the administration of hypotonic artificial tears. PMID:29475928
Kojima, Takashi; Matsumoto, Yukihiro; Ibrahim, Osama M A; Wakamatsu, Tais Hitomi; Uchino, Miki; Fukagawa, Kazumi; Ogawa, Junko; Dogru, Murat; Negishi, Kazuno; Tsubota, Kazuo
2011-11-11
To prospectively evaluate the effect of controlled adverse chamber environment (CACE) exposure on tear function, including tear osmolarity, in subjects wearing narafilcon A versus those wearing etafilcon A soft contact lens (SCL). Thirty-one healthy subjects with no history of contact lens wear (13 women, 18 men; average age, 30.5 ± 6.5 years) were randomly divided into age- and sex-matched groups (15 subjects wearing narafilcon A SCL; 16 subjects wearing etafilcon A SCL) and entered a CACE for 20 minutes. All subjects underwent tear osmolarity, tear evaporation rate, strip meniscometry, tear film breakup time, fluorescein vital staining, and functional visual acuity measurement before and after exposure to the controlled adverse chamber. The mean blink rate increased with significant deteriorations in the mean symptom VAS scores, mean tear osmolarity, tear evaporation rate, strip meniscometry score, and tear stability with CACE exposure along with a decrease in visual maintenance ratio in functional visual acuity testing in etafilcon A wearers. The mean symptom VAS scores, mean tear evaporation rate, tear stability, blink rates, and visual maintenance ratios did not change significantly in narafilcon A wearers after CACE exposure. This study suggested marked tear instability, higher tear osmolarity, and increased tear evaporation with marked dry eye and visual symptomatology in nonadapted hydrogel SCL wearers, suggesting that silicone hydrogel SCLs may be suitable for persons who live and work in cool, low-humidity, and windy environments, as tested in this study.
Tear analysis in contact lens wearers.
Farris, R L
1985-01-01
Tear analysis in contact lens wearers was compared with tear analysis in aphakics without contact lens wear and normal phakic patients. Subjects were divided into five groups: group 1, aphakic without contact lens; group 2, phakic with daily-wear hard contact lens; group 3, phakic with daily-wear soft contact lens; group 4, phakic with extended-wear soft contact lens; and group 5, aphakic with extended-wear soft contact lens. The experimental groups were compared with age- and sex-matched control groups for statistical analysis of tear variables by means of the Student's t-test. The variables measured were tear osmolarity, tear albumin, and lysozyme and lactoferrin concentrations in basal and reflex tears. Highly significant elevations of tear osmolarity were found in aphakic subjects without contact lenses. Less significant differences in tear osmolarity were found in phakic subjects with hard daily-wear lenses or with extended-wear soft lenses. Tear albumin, lysozyme, and lactoferrin in basal and reflex tears were not significantly different in the different groups of contact lens wearers or in the group of aphakic subjects without contact lenses compared with their control groups. Individual variations in tear albumin, lysozyme, and lactoferrin appeared to be responsible for the inability to demonstrate significant differences in tear composition in association with the wearing of different types of contact lenses. Older and aphakic patients demonstrated a tendency to have increased concentrations of proteins in the tears compared with younger, phakic contact lens wearers and normal controls without contact lenses. PMID:3914131
Maffulli, Nicola; Loppini, Mattia; Longo, Umile Giuseppe; Maffulli, Gayle D; Denaro, Vincenzo
2013-05-01
Achilles tendon ruptures represent more than 40% of all tendon ruptures requiring surgical management. About 20% of acute Achilles tendon tears are not diagnosed at the time of injury and become chronic, necessitating more complicated management than fresh injuries. Several techniques for the reconstruction of chronic tears of the Achilles tendon have been described, but the superiority of one technique over the others has not been demonstrated. Mini-invasive reconstruction of the Achilles tendon, with a gap lesion larger than 6 cm, using the ipsilateral free semitendinosus tendon graft will result in improvement of the overall function with a low rate of complications. Case series; Level of evidence, 4. Between 2008 and 2010, the authors prospectively enrolled 28 consecutive patients (21 men and 7 women; median age, 46 years) with chronic closed ruptures of the Achilles tendon who had undergone reconstruction with a free semitendinosus tendon graft. They assessed the Achilles tendon Total Rupture Score (ATRS), maximum calf circumference, and isometric plantarflexion strength before surgery and at the last follow-up. Outcome of surgery and rate of complications were also recorded. The median follow-up after surgery was 31.4 months. The overall result of surgery was excellent/good in 26 (93%) of 28 patients. The ATRS improved from 42 (range, 29-55) to 86 (range, 78-95) (P < .0001). In the operated leg, the maximum calf circumference and isometric plantarflexion strength were significantly improved after surgery (P < .0001); however, their values remained significantly lower than those of the opposite side (P < .0001). All patients were able to walk on tiptoes and returned to their preinjury working occupation. No infections were recorded. Mini-invasive reconstruction of the Achilles tendon, with a gap lesion larger than 6 cm, using the ipsilateral free semitendinosus tendon graft provides a significant improvement of symptoms and function, although calf circumference and ankle plantarflexion strength do not recover fully.
Factors affecting healing rates after arthroscopic double-row rotator cuff repair.
Tashjian, Robert Z; Hollins, Anthony M; Kim, Hyun-Min; Teefey, Sharlene A; Middleton, William D; Steger-May, Karen; Galatz, Leesa M; Yamaguchi, Ken
2010-12-01
Double-row arthroscopic rotator cuff repairs were developed to improve initial biomechanical strength of repairs to improve healing rates. Despite biomechanical improvements, failure of healing remains a clinical problem. To evaluate the anatomical results after double-row arthroscopic rotator cuff repair with ultrasound to determine postoperative repair integrity and the effect of various factors on tendon healing. Case series; Level of evidence, 4. Forty-eight patients (49 shoulders) who had a complete arthroscopic rotator cuff repair (double-row technique) were evaluated with ultrasound at a minimum of 6 months after surgery. Outcome was evaluated at a minimum of 1-year follow-up with standardized history and physical examination, visual analog scale for pain, active forward elevation, and preoperative and postoperative shoulder scores according to the system of the American Shoulder and Elbow Surgeons and the Simple Shoulder Test. Quantitative strength was measured postoperatively. Ultrasound and physical examinations were performed at a minimum of 6 months after surgery (mean, 16 months; range, 6 to 36 months) and outcome questionnaire evaluations at a minimum of 12 months after surgery (mean, 29 months; range, 12 to 55 months). Of 49 repairs, 25 (51%) were healed. Healing rates were 67% in single-tendon tears (16 of 24 shoulders) and 36% in multitendon tears (9 of 25 shoulders). Older age and longer duration of follow-up were correlated with poorer tendon healing (P < .03). Visual analog scale for pain, active forward elevation, American Shoulder and Elbow Surgeons scores, and Simple Shoulder Test scores all had significant improvement from baseline after repair (P < .0001). Increased age and longer duration of follow-up were associated with lower healing rates after double-row rotator cuff repair. The biological limitation at the repair site, as reflected by the effects of age on healing, appears to be the most important factor influencing tendon healing, even after maximizing repair biomechanical strength with a double-row construct.
Paralabral rupture of the proximal biceps tendon from light weightlifting.
Miller, Kyle E; Solomon, Daniel J
2008-12-01
Rupture of the long head of the biceps is usually seen in older adults, in conjunction with rotator cuff tears or tenosynovitis secondary to chronic subacromial impingement; it is rarely seen as a result of trauma. We present the case of a young active patient who denied prodromal symptoms but ruptured the long head of the biceps brachii tendon (LHB) while performing 25-pound biceps curls. Upon examination, the patient was noted to have a readily apparent biceps defect and decreased strength. He was brought to the operating room, where open subpectoral tenodesis of the LHB was performed. At the 6-week follow-up evaluation, the patient had regained full range of motion. By 6 months, he had regained his previous strength. This case demonstrates an unusual presentation of a LHB rupture in a young healthy man with no prodromal symptoms.
Mechanical and Tear Properties of Fabric/Film Laminates
NASA Technical Reports Server (NTRS)
Said, Magdi A.
1998-01-01
Films reinforced with woven fabrics are being considered for the development of a material suitable for long duration scientific balloons under a program managed by the National Aeronautics and Space Administration (NASA). Recently developed woven fabrics provide a relatively high strength to weight ratio compared to standard homogenous films. Woven fabrics also have better crack propagation resistance and rip stop capabilities when compared to homogenous lightweight, high strength polymeric films such as polyester and nylon. If joining is required, such as in the case of scientific balloons, woven fabrics have the advantage over polymeric thin films to utilize traditional textile methods as well as other techniques including hot sealing, adhesion, and ultrasonic means. Woven fabrics, however, lack the barrier properties required for helium filled scientific balloons, therefore lamination with homogenous films is required to provide the gas barrier capabilities required in these applications.
Behavioral and neural responses to infant and adult tears: The impact of maternal love withdrawal.
Riem, Madelon M E; van IJzendoorn, Marinus H; De Carli, Pietro; Vingerhoets, Ad J J M; Bakermans-Kranenburg, Marian J
2017-09-01
The current study examined behavioral and neural responses to infant and adult tears, taking into account childhood experiences with parental love-withdrawal. With functional MRI (fMRI), we measured neural reactivity to pictures of infants and adults with and without tears on their faces in nulliparous women with varying childhood experiences of maternal use of love withdrawal. Behavioral responses to infant and adult tears were measured with an approach-avoidance task. We found that individuals with experiences of love withdrawal showed less amygdala and insula reactivity to adult tears, but love withdrawal did not affect amygdala and insula reactivity to infant tears. During the approach-avoidance task, individuals responded faster to adult tears in the approach condition compared with the avoidance condition, indicating that adult tears facilitate approach behavior. Individuals responded faster to infant tears than to adult tears, regardless of approach or avoidance condition. Our findings suggest that infant tears are highly salient and may, therefore, overrule the effects of contextual and personal characteristics that influence the perception of adult crying. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
[Rotator cuff tear athropathy prevalence].
Guerra-Soriano, F; Encalada-Díaz, M I; Ruiz-Suárez, M; Valero-González, F S
2017-01-01
Glenohumeral arthritis secondary to massive rotator cuff tear presents with a superior displacement and femoralization of the humeral head with coracoacromial arch acetabularization. The purpose of this study was to establish prevalence of rotator cuff tear artropathy (CTA) at our institution. Four hundred electronic records were reviewed from which we identified 136 patients with rotator cuff tears. A second group was composed with patients with massive cuff tears that were analized and staged by the Seebauer cuff tear arthropathy classification. Thirty four patients with massive rotator cuff tears were identified, 8 male and 26 female (age 60.1 ± 10.26 years). Massive rotator cuff tear prevalence was 25%. CTA prevalence found in the rotator cuff group was 19 and 76% in the massive cuff tears group. Patients were staged according to the classification with 32% in stage 1a, 11% 1b, 32% 2a and 0% 2b. CTA prevalence in patients with rotator cuff tears and massive cuff tears is higher than the one reported in American population. We consider that a revision of the Seebauer classification to be appropriate to determine its reliability.
Choi, Chul-Jun; Choi, Yun-Jin; Song, In-Bum; Choi, Chong-Hyuk
2011-06-01
The clinical and radiologic features of radial tears of the medial meniscus posterior horn were compared with those of horizontal tears. From January 2007 to December 2008, 387 consecutive cases of medial meniscal tears were treated arthroscopically. Among these, 91 were radial tears in the medial meniscus posterior horn, and 95 were horizontal tears in the posterior segment of the medial meniscus. The patients' data (age, gender, duration of symptom, body mass index, and injury history), radiographic findings (Kellgren and Lawrence score, posterior tibial slope, and femorotibial angle), and chondral lesions were recorded. The patient factors of age, gender, and body mass index were related to radial tears of the medial meniscus posterior horn. Radial tears were significantly correlated with Kellgren and Lawrence score, varus alignment, posterior tibial slope, and severity of the chondral lesion. Radial tears of the medial meniscus posterior horn are a unique clinical entity that are associated with older age, females and obesity, and are strongly associated with an increased incidence and severity of cartilage degeneration compared to horizontal tears.
The Coracohumeral Distance in Shoulders With Traumatic and Degenerative Subscapularis Tendon Tears.
Balke, Maurice; Banerjee, Marc; Greshake, Oliver; Hoeher, Juergen; Bouillon, Bertil; Liem, Dennis
2016-01-01
A reduced coracohumeral distance (CHD) is thought to be responsible for subcoracoid impingement. This only accounts for degenerative tendon tears. In traumatic tears, the subcoracoid space should be normal. The CHD in patients with traumatic subscapularis tendon tears is larger than that in patients with degenerative tears and does not differ from patients with an intact subscapularis tendon. Cohort study; Level of evidence, 3. A total of 83 patients with arthroscopically certified subscapularis tendon tears were included in the study. Forty-four patients had degenerative causes (group 1), and 39 had traumatic causes (group 2). The control group consisted of 20 patients with traumatic supraspinatus tendon tears and arthroscopically proven, intact subscapularis tendons (group 3). On preoperative axial magnetic resonance imaging, the distance between the CHD was measured, and the values of the 3 groups were compared using the t test. The mean (±SD) CHD in patients with degenerative subscapularis tendon tears was 8.6 ± 2.0 mm (range, 4.0-13.2 mm) and was significantly (P = .0003) smaller than that in patients with traumatic tears (10.2 ± 2.0 mm; range, 6.6-16.2 mm) or controls (10.4 ± 1.8 mm; range, 6.8-14.0 mm). The CHD of controls and patients with traumatic tears did not differ significantly (P = .7875). A CHD of less than 6 mm only occurred in patients with degenerative subscapularis tendon tears. The hypothesis that the CHD in patients with degenerative subscapularis tendon tears is significantly smaller than that in patients with traumatic tears or intact subscapularis tendons was confirmed. The CHD in patients with traumatic tears does not differ from that in controls. A CHD of less than 6 mm only occurs in patients with degenerative subscapularis tendon tears. © 2015 The Author(s).
Sanada, Hiromi; Nakagami, Gojiro; Koyano, Yuiko; Iizaka, Shinji; Sugama, Junko
2015-08-01
There is a lack of data from cohort studies for the incidence of skin tears among an elderly population in an Asian country. We estimated the cumulative incidence of skin tear, and identify its risk factor. The present prospective cohort study was carried out at a long-term medical facility in Japan. Participants included patients (n = 368) aged 65 years or older receiving hospital care. The 3-month cumulative incidence of skin tears was estimated by identifying them using direct inspection of the extremities. In order to find the risk factors for the skin tear incidence, odds ratios and their 95% confidence intervals of skin tear development in association with the factors were estimated using logistic regression analyses. A total of 14 patients developed skin tears, and their cumulative incidence was 3.8%. No patients with skin tears developed multiple wounds on their extremities. Half of the skin tears occurred on the outside of the right forearm, and just three skin tears were found in the lower legs. Multiple logistic analyses showed that pre-existing skin tears (odds ratio 15.42, 95% confidence interval 3.53-67.43, P < 0.001) and a 6-point decrease in the total score of the Braden Scale (odds ratio 0.10, 95% confidence interval 0.01-0.83, P < 0.033) were significantly associated with skin tear development. Patients with pre-existing skin tears and a low score of the Braden Scale have a higher risk of skin tear development during 3 months. These factors could be used to identify patients requiring prevention care for skin tears. © 2014 Japan Geriatrics Society.
Yeo, Daniel Y T; Walton, Judie R; Lam, Patrick; Murrell, George A C
2017-03-01
Rotator cuff repair often results in significant pain postoperatively, the cause of which is undetermined. Purpose/Hypothesis: The aim of this study was to evaluate the relationship between rotator cuff tear area and postoperative pain in patients who had undergone arthroscopic rotator cuff repair. We hypothesized that larger tears would be more painful because of elevated repair tension at 1 week postoperatively but that smaller tears would be more painful because of a greater healing response, especially from 6 weeks postoperatively. Cohort study; Level of evidence, 3. A total of 1624 patients who underwent arthroscopic rotator cuff repair were included in this study. Exclusion criteria were moderate to severe osteoarthritis, isolated subscapularis repair, calcific tendinitis, synthetic patch repair, revision surgery, and retears on ultrasound at 6 months after surgery. Rotator cuff tears were subdivided into groups based on the tear size and retear rate found for each group. A modified L'Insalata questionnaire was given before surgery and at 1 week, 6 weeks, 3 months, and 6 months after surgery. Pearson and Spearman correlation coefficient tests were performed between rotator cuff tear areas and pain scores. Intraoperative rotator cuff tear areas did not correlate with pain scores preoperatively or at 1 week after surgery. A smaller tear area was associated with more frequent and severe pain with overhead activities, at rest, and during sleep as well as a poorer perceived overall shoulder condition at 6 weeks, 3 months, and 6 months after repair ( r = 0.11-0.23, P < .0001). Patients who were younger, had partial-thickness tears, and had occupational injuries experienced more pain postoperatively ( r = 0.10-0.28, P < .0001). Larger tears did not have more pain at 1 week after surgery. The retear rate was 7% in tears <2 cm 2 but reached 44% in tears >8 cm 2 . There were fewer retears with smaller tears, but they were more painful than large tears postoperatively from 6 weeks to 6 months after surgery. Smaller tears may heal more vigorously, causing more pain. Patients with smaller tears experienced more pain after rotator cuff repair compared with patients with larger tears. These findings are contrary to previous ideas about tear size and postoperative pain. Healing is likely a determinant of postoperative pain.
Tocci, Stephen L; Tashjian, Robert Z; Leventhal, Evan; Spenciner, David B; Green, Andrew; Fleming, Braden C
2008-01-01
This study determined the effect of tear size on gap formation of single-row simple-suture arthroscopic rotator cuff repair (ARCR) vs transosseous Mason-Allen suture open RCR (ORCR) in 13 pairs of human cadaveric shoulders. A massive tear was created in 6 pairs and a large tear in 7. Repairs were cyclically tested in low-load and high-load conditions, with no significant difference in gap formation. Under low-load, gapping was greater in massive tears. Under high-load, there was a trend toward increased gap with ARCR for large tears. All repairs of massive tears failed in high-load. Gapping was greater posteriorly in massive tears for both techniques. Gap formation of a modeled RCR depends upon the tear size. ARCR of larger tears may have higher failure rates than ORCR, and the posterior aspect appears to be the site of maximum gapping. Specific attention should be directed toward maximizing initial fixation of larger rotator cuff tears, especially at the posterior aspect.
Ultrasound determination of rotator cuff tear repairability
Tse, Andrew K; Lam, Patrick H; Walton, Judie R; Hackett, Lisa
2015-01-01
Background Rotator cuff repair aims to reattach the torn tendon to the greater tuberosity footprint with suture anchors. The present study aimed to assess the diagnostic accuracy of ultrasound in predicting rotator cuff tear repairability and to assess which sonographic and pre-operative features are strongest in predicting repairability. Methods The study was a retrospective analysis of measurements made prospectively in a cohort of 373 patients who had ultrasounds of their shoulder and underwent rotator cuff repair. Measurements of rotator cuff tear size and muscle atrophy were made pre-operatively by ultrasound to enable prediction of rotator cuff repairability. Tears were classified following ultrasound as repairable or irreparable, and were correlated with intra-operative repairability. Results Ultrasound assessment of rotator cuff tear repairability has a sensitivity of 86% (p < 0.0001) and a specificity of 67% (p < 0.0001). The strongest predictors of rotator cuff repairability were tear size (p < 0.001) and age (p = 0.004). Sonographic assessments of tear size ≥4 cm2 or anteroposterior tear length ≥25 mm indicated an irreparable rotator cuff tear. Conclusions Ultrasound assessment is accurate in predicting rotator cuff tear repairability. Tear size or anteroposterior tear length and age were the best predictors of repairability. PMID:27582996
Tear Film Osmolarity in Subjects with Acute Allergic Rhinoconjunctivitis.
Nitoda, Eirini; Lavaris, Anastasios; Laios, Konstantinos; Androudi, Sophia; Kalogeropoulos, Chris D; Tsatsos, Michael; Damaskos, Christos; Garmpis, Nikolaos; Moschos, Marilita M
2018-01-01
Acute allergic rhinoconjuctivitis is the most common form of ocular allergies. The pathogenetic mechanisms are based on an immunoglobulin E (IgE)-mediated hypersensitivity reaction. On the other hand, tear osmolarity has been suggested to be an index of ocular surface damage and inflammation. These data were the motive to investigate the levels of tear osmolarity in subjects with acute allergic rhinoconjuctivitis, before and after administration of artificial tears. Forty-five subjects with acute allergic rhinoconjuctivitis were randomly divided into three groups, based on the type of artificial tears that they received: Group A (Thera tears), Group B (Wet therapy) and Group C (Tears Naturale free). The eye drops were administered six times a day for 60 days and all subjects underwent grading of subjective symptoms and clinical examination at baseline and at the end of the treatment. The diagnosis of severe eye disease, which was based on ocular surface disease index (OSDI; Allergan, Inc, Irvine, CA, USA) and tear osmolarity values, concerned all patients at baseline. Although the administration of artificial tears significantly ameliorated the symptoms and the ocular variables in all groups, the results were better in the first group. Tear osmolarity was strongly and negatively correlated with tear film breakup time (BUT) and Schirmer I test at 2 months. Contrariwise, symptoms were eliminated, when tear osmolarity was decreased. Acute allergic rhinoconjuctivitis is characterized by tear hyperosmolarity, which can be rehabilitated with the administration of hypotonic artificial tears. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.
Johandi, Faisal; Sechachalam, Sreedharan
2017-01-01
We evaluate the clinical and functional outcome of open primary repair of acute TFCC tears in distal radius fracture, when there is gross intraoperative distal radioulnar joint (DRUJ) instability after fixation of the distal radius, in the absence of an ulnar styloid fracture or when the ulnar fracture fragment is too small to be fixed. A retrospective review of our institution's distal radius fracture database over a 4-year period (January 2010 to December 2013). A total of 12 (1.38%) out of 3379 patients had an open TFCC repair in the same setting as fixation of distal radius. Assessment of outcome involved the analysis of objective and subjective clinical and functional outcomes. All patient regained Activities of Daily Living (ADL) independence; eleven out of 12 patients (91.7%) returned to pre-injury function and 8 out of 11 patients (72.7%) returned to their jobs. DRUJ stability was preserved in 10 patients (83.3%) with 10 patients (83.3%) having grip strength of at least 50%, compared to the uninjured hand, and 7 (58.3%) with grip strength of more than or equal to 75%. Complications of surgery identified can be classified into 4 broad categories: infection, neurological complications, persistent DRUJ instability and prolonged pain. The authors believe a primary open repair of the TFCC should be considered when patients present with instability during intra-operative DRUJ ballottement test after distal radius fixation, in the absence of an ulnar styloid fracture or when the ulnar fracture fragment is too small to be fixed.
NASA Astrophysics Data System (ADS)
Matsumoto, Yu; Takai, Kenichi
2018-02-01
A stress application method in delayed fracture susceptibility tests was investigated using 1450 MPa class tempered martensitic steel. Its fracture mode under hydrogen charging was mainly intergranular because of its relatively small Si content of 0.21 mass pct. The conditions for consistency in fracture strength between tensile tests and constant load tests (CLTs) were clarified: first, to conduct hydrogen precharging before stress application; and second, to choose a sufficiently low crosshead speed in tensile tests. When hydrogen precharging was not conducted before CLTs, the fracture strength was higher than the values in CLTs with hydrogen charging and in tensile tests. If the crosshead speed was too high, the fracture strength obtained was higher than the values in CLTs. The dependence of the fracture strength on crosshead speed was seen for both notched and smooth bar specimens. These results suggested that plastic deformation, i.e., dislocation motion, was related to intergranular fracture with a tear pattern as well as to quasi-cleavage fracture. In addition, cathodic electrolysis in an alkaline solution containing NaOH should be used as the hydrogen charging method to avoid the effects of corrosion.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 3 2013-10-01 2013-10-01 false Tear test. 178.1070 Section 178.1070... Containers § 178.1070 Tear test. (a) General. The tear test must be conducted for the qualification of all of Flexible Bulk Containers design types. (b) Special preparation for the tear test. Flexible Bulk Container...
Human tears contain a chemosignal.
Gelstein, Shani; Yeshurun, Yaara; Rozenkrantz, Liron; Shushan, Sagit; Frumin, Idan; Roth, Yehudah; Sobel, Noam
2011-01-14
Emotional tearing is a poorly understood behavior that is considered uniquely human. In mice, tears serve as a chemosignal. We therefore hypothesized that human tears may similarly serve a chemosignaling function. We found that merely sniffing negative-emotion-related odorless tears obtained from women donors induced reductions in sexual appeal attributed by men to pictures of women's faces. Moreover, after sniffing such tears, men experienced reduced self-rated sexual arousal, reduced physiological measures of arousal, and reduced levels of testosterone. Finally, functional magnetic resonance imaging revealed that sniffing women's tears selectively reduced activity in brain substrates of sexual arousal in men.
Tear thinning time and topical anesthesia as assessed using the HIRCAL grid and the NCCA.
Blades, K J; Murphy, P J; Patel, S
1999-03-01
The literature contains conflicting reports of the effects of topical anesthetics on tear film stability, with some consensus that unpreserved topical anesthetics are less likely to reduce tear film stability than preserved preparations. This experiment investigated the effect of unpreserved 0.4% benoxinate hydrochloride on tear thinning time (TTT), in parallel with "real time" corneal sensitivity assessment. Tear film stability was assessed (HIRCAL grid) in parallel with real time assessment of the pharmacological activity (NCCA) of unpreserved 0.4% benoxinate hydrochloride in normal eyes. The anesthetic used did not significantly affect tear film stability. This finding is in agreement with previous investigators. Unpreserved 0.4% benoxinate hydrochloride could be used to facilitate tear film stability assessment. The experimental protocol used could also be applied to investigate the temporal relationship between anesthesia and tear film stability with preserved topical anesthetics that have been found to decrease tear film stability.
Tear exchange and contact lenses: A review
Muntz, Alex; Subbaraman, Lakshman N.; Sorbara, Luigina; Jones, Lyndon
2015-01-01
Tear exchange beneath a contact lens facilitates ongoing fluid replenishment between the ocular surface and the lens. This exchange is considerably lower during the wear of soft lenses compared with rigid lenses. As a result, the accumulation of tear film debris and metabolic by-products between the cornea and a soft contact lens increases, potentially leading to complications. Lens design innovations have been proposed, but no substantial improvement in soft lens tear exchange has been reported. Researchers have determined post-lens tear exchange using several methods, notably fluorophotometry. However, due to technological limitations, little remains known about tear hydrodynamics around the lens and, to-date, true tear exchange with contact lenses has not been shown. Further knowledge regarding tear exchange could be vital in aiding better contact lens design, with the prospect of alleviating certain adverse ocular responses. This article reviews the literature to-date on the significance, implications and measurement of tear exchange with contact lenses. PMID:25575892
Tear dysfunction and the cornea: LXVIII Edward Jackson Memorial Lecture.
Pflugfelder, Stephen C
2011-12-01
To describe the cause and consequence of tear dysfunction-related corneal disease. Perspective on effects of tear dysfunction on the cornea. Evidence is presented on the effects of tear dysfunction on corneal morphology, function, and health, as well as efficacy of therapies for tear dysfunction-related corneal disease. Tear dysfunction is a prevalent eye disease and the most frequent cause for superficial corneal epithelial disease that results in corneal barrier disruption, an irregular optical surface, light scattering, optical aberrations, and exposure and sensitization of pain-sensing nerve endings (nociceptors). Tear dysfunction-related corneal disease causes irritation and visual symptoms such as photophobia and blurred and fluctuating vision that may decrease quality of life. Dysfunction of 1 or more components of the lacrimal functional unit results in changes in tear composition, including elevated osmolarity and increased concentrations of matrix metalloproteinases, inflammatory cytokines, and chemokines. These tear compositional changes promote disruption of tight junctions, alter differentiation, and accelerate death of corneal epithelial cells. Corneal epithelial disease resulting from tear dysfunction causes eye irritation and decreases visual function. Clinical and basic research has improved understanding of the pathogenesis of tear dysfunction-related corneal epithelial disease, as well as treatment outcomes. Copyright © 2011 Elsevier Inc. All rights reserved.
Increased Tear Film Osmolarity in Systemic Lupus Erythematosus.
Duru, Necati; Altinkaynak, Hasan; Uysal, Betul Seher; Duru, Zeynep; Can, Mehmet Erol; Erten, Sukran; Yuksel, Nilay; Kalkan Akcay, Emine
2017-01-01
To evaluate tear film osmolarity in patients with systemic lupus erythematosus (SLE). A total of 55 eyes from 55 patients with SLE and 47 eyes from 47 age- and gender-matched healthy individuals were included in this study. Tear film osmolarity was evaluated with a lab-on-a-chip technique (TearLab; TearLab Corporation, San Diego, CA) in SLE patients in comparison with healthy individuals, and results were correlated to clinically available diagnostic tests for dry eye, such as tear film break-up time (BUT), Schirmer's test, and Ocular Surface Disease Index (OSDI). The mean tear film osmolarity in the SLE patients and healthy individuals was 306.02 ± 13.27 mOsm/L and 300.74 ± 9.11 mOsm/L, respectively, which made for a statistically significant difference (p = 0.020). In the SLE group, tear film osmolarity was negatively correlated with the Schirmer's test score and the BUT value (r = -0.295 p = 0.029 and r = 0.347 p = 0.009, respectively), whereas tear film osmolarity was not correlated with OSDI score (r = -0.182 p = 0.183). This study revealed that tear film hyperosmolarity and abnormal tear film function are associated with SLE.
Emotional tears facilitate the recognition of sadness and the perceived need for social support.
Balsters, Martijn J H; Krahmer, Emiel J; Swerts, Marc G J; Vingerhoets, Ad J J M
2013-02-12
The tearing effect refers to the relevance of tears as an important visual cue adding meaning to human facial expression. However, little is known about how people process these visual cues and their mediating role in terms of emotion perception and person judgment. We therefore conducted two experiments in which we measured the influence of tears on the identification of sadness and the perceived need for social support at an early perceptional level. In two experiments (1 and 2), participants were exposed to sad and neutral faces. In both experiments, the face stimuli were presented for 50 milliseconds. In experiment 1, tears were digitally added to sad faces in one condition. Participants demonstrated a significant faster recognition of sad faces with tears compared to those without tears. In experiment 2, tears were added to neutral faces as well. Participants had to indicate to what extent the displayed individuals were in need of social support. Study participants reported a greater perceived need for social support to both sad and neutral faces with tears than to those without tears. This study thus demonstrated that emotional tears serve as important visual cues at an early (pre-attentive) level.
Kan, Akinori; Oshida, Midori; Oshida, Shigemi; Imada, Masato; Nakagawa, Takumi; Okinaga, Shuji
2010-01-12
Traumatic injury and surgical meniscectomy of a medial meniscus are known to cause subsequent knee osteoarthritis. However, the difference in the prevalence of osteoarthritis caused by the individual type of the medial meniscal tear has not been elucidated. The aim of this study was to investigate what type of tear is predominantly responsible for the degradation of articular cartilage in the medial compartment of knee joints. Five hundred and forty eight cadaveric knees (290 male and 258 female) were registered in this study. The average age of cadavers at death was 78.8 years old (range: 52-103 years). The knees were macroscopically examined and their medial menisci were classified into four groups according to types of tears: "no tear", "radial tear of posterior horn", "other types of tear" and "worn-out meniscus" groups. The severity of cartilage degradation in their medial compartment of knee joints was evaluated using the international cartilage repair society (ICRS) grading system. We statistically compared the ICRS grades among the groups using Mann-Whitney U test. The knees were assigned into the four groups: 416 "no tear" knees, 51 "radial tear of posterior horn" knees, 71 "other types of tear" knees, and 10 "worn-out meniscus" knees. The knees with substantial meniscal tears showed the severer ICRS grades of cartilage degradation than those without meniscal tears. In addition, the ICRS grades were significantly severer in the "radial tear of posterior horn" group than in the "other types of tear" group, suggesting that the radial tear of posterior horn in the medial meniscus is one of the risk factors for cartilage degradation of joint surface. We have clarified the relationship between the radial tear of posterior horn in the medial meniscus and the severer grade of cartilage degradation. This study indicates that the efforts should be made to restore the anatomical role of the posterior horn in keeping the hoop strain, when patients' physical activity levels are high and the tear pattern is simple enough to be securely sutured.
van der List, Jelle P.; Mintz, Douglas N.; DiFelice, Gregory S.
2017-01-01
Background: Over the past decade, there has been a resurgence of interest in anterior cruciate ligament (ACL) preservation. Proximal and distal avulsion tears have been treated with arthroscopic primary repair, while augmented repair, remnant tensioning, primary repair with biological scaffold, and remnant preservation have been proposed for different types of midsubstance tears. Currently, the incidence of these different tear types is unknown. Purpose: To propose a magnetic resonance imaging (MRI) classification system for different tear types based on clinical relevance and to assess the distribution of these different ACL tear types. Study Design: Case series; Level of evidence, 4. Methods: A retrospective search in an institutional radiographic database was performed for patients who underwent knee MRI at our institution between June 2014 and June 2016. Patients younger than 18 years and those with reports of chronic tears, partial tears, multiligamentous injuries, were excluded. Tear types were graded as proximal avulsion (distal remnant length >90% of total ligament length, type I), proximal (75%-90%, type II), midsubstance (25%-75%, type III), distal (10%-25%, type IV), and distal avulsion (<10%, type V). An orthopaedic surgeon, a radiologist, and a research fellow graded the tear type on 30 MRIs to determine reliability, and the research fellow graded all MRIs. Inter- and intraobserver reliability were measured using kappa statistics. Results: A total of 353 patients (57% male; mean age, 37.1 years; range, 18.1-81.2 years) were included. Interobserver reliability was 0.670 (95% confidence interval, 0.505-0.836), and intraobserver reliability ranged from 0.741 to 0.934. Incidence of type I tears was 16%, type II tears 27%, type III tears 52%, type IV tears 1%, and type V tears 3% (2.5% with bony avulsion). Type I tears were more common in patients older than 35 years compared with those younger than 35 years (23% vs 8%; P < .001). Conclusion: This classification system was reliable in assessing tear location in acute ACL injuries. Type I tears were seen in 16%, type II in 27%, and type III in 52% of patients in our cohort. These data suggest that there may be greater potential application for ACL preservation techniques. PMID:28680889
Essa, Laika; Laughton, Deborah; Wolffsohn, James S
2018-02-01
To assess dry eye treatment with four preservative-free dry eye artificial tear treatments to facilitate evidence-based prescribing. A randomised, single masked crossover trial of Clinitas Soothe, Hyabak, Tears Again and TheraTears artificial tears was conducted on 50 symptomatic dry eye patients, aged 60.8±14.2years. At baseline and after trialling each treatment for 4 weeks, signs and symptoms were assessed using the Ocular Surface Disease Index (OSDI), non-invasive tear break-up time, fluorescein tear break-up time, tear meniscus height (TMH), Phenol Red test, lid-parallel conjunctival folds (LIPCOF), ocular surface staining, and lipid layer grading and osmolarity (baseline visit only). OSDI (p=0.002), LIPCOF (p=0.014) and conjunctival staining (p<0.001) significantly improved from baseline, however, the impact of each dry eye treatment on ocular symptoms and signs was similar. Clinitas Soothe and Hyabak were preferred by 34%/30% of participants, but only subjective comparison with the other drops influenced this choice. TheraTears was preferred (by 24%) by those with a lower baseline tear volume (p=0.01) and Tears Again (by 12%) by those with a thinner baseline lipid layer (p=0.04). The treatment that afforded the greatest improvement in clinical signs did not consistently match each individual's preferred treatment. If prescribed to a general dry eye population, the artificial tears performed similarly, improving symptoms and conjunctival signs. However, osmolarity balanced artificial tears were the preferred treatment in individuals with low baseline tear volume and lipisomal spray for individuals with a baseline lipid layer deficiency. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Nich, C; Dhiaf, N; Di Schino, M; Augereau, B
2014-11-01
Partial tearing of the infraspinatus and/or subscapularis tendon(s) is frequently associated with supraspinatus full-thickness tears. However, limited data regarding its influence on supraspinatus surgical repair is available. Our aim was to assess the functional and anatomical outcomes of open repair of supraspinatus full-thickness tears combined with adjacent partial tearing, comparatively to a control. We retrospectively identified 22 patients (22 shoulders) with a partial tear, most of them being a delamination tear, of the infraspinatus and/or subscapularis tendons associated with a complete detachment of the supraspinatus tendon. Twenty-seven patients (27 shoulders) treated for an isolated complete detachment of the supraspinatus tendon by open repair served as controls. The mean age was 58 years. A proximalized trans-osseous reinsertion of the supraspinatus tendon was combined with a curettage-closure of the delamination tear. Patients were evaluated with standardized MRI at last follow-up. At a mean of 75-month follow-up, the presence of a partial tear of either infraspinatus or subscapularis, or both, did not influence function and healing rates of supraspinatus tendon repair. Conversely to the control, when a retear occurred, the functional score tended to worsen. Preoperatively, fatty muscular degeneration was more pronounced when a partial tear was present. Fatty degeneration worsened regardless of repair healing. Open reinsertion of a supraspinatus full-thickness tear associated with a thorough treatment of partial tear of adjacent tendons led to optimal functional and anatomical mid term outcomes. Our results suggest the presence of a partial tear of adjacent tendons could be associated with poorer function in case of supraspinatus tendon re-rupture. Level III case-control study. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 3 2013-10-01 2013-10-01 false Tear test. 178.818 Section 178.818 Transportation... Tear test. (a) General. The tear test must be conducted for the qualification of all flexible IBC design types. (b) Special preparation for the tear test. The flexible IBC must be filled to not less than...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 2 2010-10-01 2010-10-01 false Tear test. 178.818 Section 178.818 Transportation... § 178.818 Tear test. (a) General. The tear test must be conducted for the qualification of all flexible IBC design types. (b) Special preparation for the tear test. The flexible IBC must be filled to not...
Lam, Sin Man; Tong, Louis; Duan, Xinrui; Petznick, Andrea; Wenk, Markus R.; Shui, Guanghou
2014-01-01
The tear film covers the anterior eye and the precise balance of its various constituting components is critical for maintaining ocular health. The composition of the tear film amphiphilic lipid sublayer, in particular, has largely remained a matter of contention due to the limiting concentrations of these lipid amphiphiles in tears that render their detection and accurate quantitation tedious. Using systematic and sensitive lipidomic approaches, we validated different tear collection techniques and report the most comprehensive human tear lipidome to date; comprising more than 600 lipid species from 17 major lipid classes. Our study confers novel insights to the compositional details of the existent tear film model, in particular the disputable amphiphilic lipid sublayer constituents, by demonstrating the presence of cholesteryl sulfate, O-acyl-ω-hydroxyfatty acids, and various sphingolipids and phospholipids in tears. The discovery and quantitation of the relative abundance of various tear lipid amphiphiles reported herein are expected to have a profound impact on the current understanding of the existent human tear film model. PMID:24287120
Artificial tears potpourri: a literature review
Moshirfar, Majid; Pierson, Kasey; Hanamaikai, Kamalani; Santiago-Caban, Luis; Muthappan, Valliammai; Passi, Samuel F
2014-01-01
Numerous brands and types of artificial tears are available on the market for the treatment of dysfunctional tear syndrome. Past literature has focused on comparing the components of these products on patient’s clinical improvement. The wide array of products on the market presents challenges to both clinicians and patients when trying to choose between available tear replacement therapies. Different formulations affect patients based on etiology and severity of disease. In order to provide an unbiased comparison between available tear replacement therapies, we conducted a literature review of existing studies and National Institutes of Health clinical trials on commercially available, brand name artificial tears. Outcomes evaluated in each study, as well as the percent of patients showing clinical and symptomatic improvement, were analyzed. Fifty-one studies evaluating different brands of artificial tears, and their efficacy were identified. Out of the 51 studies, 18 were comparison studies testing brand name artificial tears directly against each other. Nearly all formulations of artificial tears provided significant benefit to patients with dysfunctional tear syndrome, but some proved superior to others. From the study data, a recommended treatment flowchart was derived. PMID:25114502
Numerical MHD study for plasmoid instability in uniform resistivity
NASA Astrophysics Data System (ADS)
Shimizu, Tohru; Kondoh, Koji; Zenitani, Seiji
2017-11-01
The plasmoid instability (PI) caused in uniform resistivity is numerically studied with a MHD numerical code of HLLD scheme. It is shown that the PI observed in numerical studies may often include numerical (non-physical) tearing instability caused by the numerical dissipations. By increasing the numerical resolutions, the numerical tearing instability gradually disappears and the physical tearing instability remains. Hence, the convergence of the numerical results is observed. Note that the reconnection rate observed in the numerical tearing instability can be higher than that of the physical tearing instability. On the other hand, regardless of the numerical and physical tearing instabilities, the tearing instability can be classified into symmetric and asymmetric tearing instability. The symmetric tearing instability tends to occur when the thinning of current sheet is stopped by the physical or numerical dissipations, often resulting in the drastic changes in plasmoid chain's structure and its activity. In this paper, by eliminating the numerical tearing instability, we could not specify the critical Lundquist number Sc beyond which PI is fully developed. It suggests that Sc does not exist, at least around S = 105.
[Abnormal of tear lipid layer and recent advances in clinical study of dry eye].
Xiao, Xin-Ye; Liu, Zu-Guo
2012-03-01
Dry eye is a common disease in the ophthalmological clinic, which is related to the dysfunction of tear film. The tear film is composed of lipid layer, aqueous layer and mucin layer (or lipid layer, aqueous/mucin layer). The lipid of the outmost layer derived from Meibomian gland and distributed on the tear film after blinking can decrease the evaporation and stabilize the tear film. The thickness, quality, and distribution of lipid layer are impaired in many dry eye patients, hence restoring the physiological function of lipid layer may be crucial for the treatment of this kind of dry eye. The lipid artificial tears manifest great effects on increasing lipid layer thickness, stabilizing tear film, improving Meibomian gland dysfunction, and promoting tear film distribution.
Phospholipid transfer protein is present in human tear fluid.
Jauhiainen, Matti; Setälä, Niko L; Ehnholm, Christian; Metso, Jari; Tervo, Timo M T; Eriksson, Ove; Holopainen, Juha M
2005-06-07
The human tear fluid film consists of a superficial lipid layer, an aqueous middle layer, and a hydrated mucin layer located next to the corneal epithelium. The superficial lipid layer protects the eye from drying and is composed of polar and neutral lipids provided by the meibomian glands. Excess accumulation of lipids in the tear film may lead to drying of the corneal epithelium. In the circulation, phospholipid transfer protein (PLTP) and cholesteryl ester transfer protein (CETP) mediate lipid transfers. To gain insight into the formation of tear film, we investigated whether PLTP and CETP are present in human tear fluid. Tear fluid samples were collected with microcapillaries. The presence of PLTP and CETP was studied in tear fluid by Western blotting, and the PLTP concentration was determined by ELISA. The activities of the enzymes were determined by specific lipid transfer assays. Size-exclusion and heparin-affinity chromatography assessed the molecular form of PLTP. PLTP is present in tear fluid, whereas CETP is not. Quantitative assessment of PLTP by ELISA indicated that the PLTP concentration in tear fluid, 10.9 +/- 2.4 microg/mL, is about 2-fold higher than that in human plasma. PLTP-facilitated phospholipid transfer activity in tears, 15.1 +/- 1.8 micromol mL(-)(1) h(-)(1), was also significantly higher than that measured in plasma. Inactivation of PLTP by heat treatment (+58 degrees C, 60 min) or immunoinhibition abolished the phospholipid transfer activity in tear fluid. Size-exclusion chromatography of tear fluid indicated that PLTP eluted in a position corresponding to a size of 160-170 kDa. Tear fluid PLTP was quantitatively bound to Heparin-Sepharose and could be eluted as a single peak by 0.5 M NaCl. These data indicate that human tear fluid contains catalytically active PLTP protein, which resembles the active form of PLTP present in plasma. The results suggest that PLTP may play a role in the formation of the tear film by supporting phospholipid transfer.
Antioxidant content and ultraviolet absorption characteristics of human tears.
Choy, Camus Kar Man; Cho, Pauline; Benzie, Iris F F
2011-04-01
Dry eye syndrome is a common age-related disorder, and decreased antioxidant/ultraviolet (UV) radiation protection in tears may be part of the cause. This study aimed to compare the tear antioxidant content and flow rate in young and older adults. The total antioxidant content and UV absorbing properties of various commercially available ophthalmic solutions used to alleviate dry eye symptoms were also examined. Minimally stimulated tears were collected from 120 healthy Chinese adults with no ocular pathology. Two age groups were studied: 19 to 29 years (n = 58) and 50 to 75 years (n = 62). Tear samples from each subject and 13 ophthalmic solutions were analyzed for total antioxidant content (as the Ferric Reducing/Antioxidant Power value). Tear flow rates were estimated from time taken to collect a fixed volume of tear fluid. UV absorbance spectra of pooled fresh reflex tear fluid and the ophthalmic solutions were determined. Results showed that the antioxidant content of minimally stimulated tears from older subjects (398 ± 160 μmol/l) was not significantly lower than that of younger subjects (348 ± 159 μmol/l; p = 0.0915). However, there was a significant difference in the tear flow rates between the two groups (p < 0.0001), with the younger group having three to four fold higher flow rate. None of the commercial preparations tested had detectable antioxidant content, and none showed the UV absorption characteristics of natural reflex tears. The effect of low flow rate on the dynamic antioxidant supply to the corneal surface indicates that older subjects have poorer overall defense against photooxidative and other oxidative processes. This could predispose older persons to corneal stress and development of dry eye syndrome. The commercially available artificial tears tested lack both the antioxidant content and UV absorbing characteristics of natural tears. Artificial tears formulations that help restore natural antioxidant and UV absorbing properties to the tear film of the aging eye may help prevent or improve dry eye symptoms and promote ocular health.
Jeon, Yoon Sang; Kim, Rag Gyu; Shin, Sang-Jin
2018-05-16
The purpose of this study was to identify the tear pattern that could be anatomically repaired by preserving the remaining tendon on footprint and evaluate clinical outcomes of patients who underwent remaining tendon preserving cuff repair. Of 523 patients with full-thickness rotator cuff tears who underwent arthroscopic repair, 41 (7.8%) patients had repairable rotator cuff tear while preserving the remaining tendon. Among them, 31 patients were followed-up for more than 2 years, including 26 patients with posterior L-shaped tear and 5 patients with transtendinous tear patterns. Clinical outcomes were evaluated using ASES and Constant score, SANE score for patient satisfaction, and VAS for pain. MRI was taken for tendon integrity 6 months postoperatively. Of the 31 patients, 11 (35.5%) had previous injury history before rotator cuff tear, including 7 (26.9%) of the 26 patients with posterior L-shaped tear and 4 (80%) of the 5 patients with transtendinous tear. The average size of preoperative cuff tear was 17.8 ± 6.8 mm in anterior-to-posterior direction and 15.2 ± 5.1 mm in medial-to-lateral direction. ASES and Constant score, SANE score, and VAS for pain were significantly (p < 0.001) improved after remaining tendon preserving rotator cuff repair. Rotator cuff tendons of 22(84.6%) patients with posterior L-shaped tear and 4(80%) patients with transtendinous tear patterns were healed. Patients who underwent rotator cuff repair with preservation of the remaining tendon on the footprint obtained satisfactory functional outcomes. Rotator cuff tears in patients who had posterior L-shaped tear extending between supraspinatus and infraspinatus tendons or transtendinous tear pattern with substantial remaining tendon could be repaired using remaining tendon preserving repair technique. Anatomic reduction of torn cuff tendon without undue tension could be achieved using the remaining tendon preserving repair technique.
[Diagnostic value of MRI for posterior root tear of medial and lateral meniscus].
Qian, Yue-Nan; Liu, Fang; Dong, Yi-Long; Cai, Chun-Yuan
2018-03-25
To explore diagnostic value of MRI on posterior root tear of medial and lateral meniscus. From January 2012 to January 2016, clinical data of 43 patients with meniscal posterior root tear confirmed by arthroscopy were retrospective analyzed, including 25 males and 18 females, aged from 27 to 69 years old with an average age of(42.5±8.3)years old;27 cases on the right side and 16 cases on the left side. MRI examinations of 43 patients with tear of posterior meniscus root confirmed by knee arthroscopies were retrospectively reviewed. MRI images were double-blinded, independently, retrospectively scored by two imaging physicians. Sensitivity, specificity and accuracy of MRI diagnosis of lateral and medial meniscus posterior root tear were calculated, and knee ligament injury and meniscal dislocation were calculated. Forty-three of 143 patients were diagnosed with meniscus posterior root tears by arthroscopy, including 19 patients with lateral tears and 24 patients with medial tears. The sensitivity, specificity and accuracy in diagnosis of posterior medial meniscus root tears for doctor A were 91.67%, 86.6% and 83.9% respectively, and for doctor B were 87.5%, 87.4% and 87.4%, 19 patients with medial meniscal protrusion and 2 patients with anterior cruciate ligament tear. The sensitivity, specificity and accuracy in diagnosis of posterior lateral meniscus root tears for doctor A were 73.7%, 79.9% and 79% respectively, and for doctor B were 78.9%, 82.3% and 82.5%, 4 patients with lateral meniscus herniation and 16 patients with cruciate ligament tear. Kappa statistics for posterior medial meniscus root tears and posterior lateral meniscus root tears were 0.84 and 0.72. MRI could effectively demonstrate imaging features of medial and lateral meniscal root tear and its accompanying signs. It could provide the basis for preoperative diagnosis of clinicians, and be worthy to be popularized. Copyright© 2018 by the China Journal of Orthopaedics and Traumatology Press.
Biomechanical evaluation of a single-row versus double-row repair for complete subscapularis tears.
Wellmann, Mathias; Wiebringhaus, Philipp; Lodde, Ina; Waizy, Hazibullah; Becher, Christoph; Raschke, Michael J; Petersen, Wolf
2009-12-01
The purpose of the study was to compare a single-row repair and a double-row repair technique for the specific characteristics of a complete subscapularis lesion. Ten pairs of human cadaveric shoulder human shoulder specimens were tested for stiffness and ultimate tensile strength of the intact tendons in a load to failure protocol. After a complete subscapularis tear was provoked, the specimens were assigned to two treatment groups: single-row repair (1) and a double-row repair using a "suture bridge" technique (2). After repair cyclic loading a subsequent load to failure protocol was performed to determine the ultimate tensile load, the stiffness and the elongation behaviour of the reconstructions. The intact subscapularis tendons had a mean stiffness of 115 N/mm and a mean ultimate load of 720 N. The predominant failure mode of the intact tendons was a tear at the humeral insertion site (65%). The double-row technique restored 48% of the ultimate load of the intact tendons (332 N), while the single-row technique revealed a significantly lower ultimate load of 244 N (P = 0.001). In terms of the stiffness, the double-row technique showed a mean stiffness of 81 N/mm which is significantly higher compared to the stiffness of the single-row repairs of 55 N/mm (P = 0.001). The double-row technique has been shown to be stronger and stiffer when compared to a conventional single-row repair. Therefore, this technique is recommended from a biomechanical point of view irrespectively if performed by an open or arthroscopic approach.
... tear film can result in excess tearing or dry eye. Because tears are necessary to keep the cornea ... redness of the eye, blurred vision, frothy tears, dry eye, or crusting of the eyelashes on awakening. Treatment ...
... smooth layer) lining these tendons. A rotator cuff tear occurs when one of the tendons is torn ... Poor posture over many years Aging Rotator cuff tears TEARS Rotator cuff tears may occur in two ...
Tearing relaxation and the globalization of transport in field-reversed configurations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steinhauer, Loren; Barnes, D. C.
2009-09-15
Tearing instability of field-reversed configurations (FRC) is investigated using the method of neighboring equilibria. It is shown that the conducting wall position in experiment lies very close to the location needed for tearing stability. This strongly suggests that vigorous but benign tearing modes, acting globally, are the engine of continual self-organization in FRCs, i.e., tearing relaxation. It also explains the ''profile consistency'' and anomalous loss rate of magnetic flux. In effect, tearing globalizes the effect of edge-driven transport.
Cemental tear: To know what we have neglected in dental practice.
Jeng, Po-Yuan; Luzi, Arlinda Luzi; Pitarch, Rocio Marco; Chang, Mei-Chi; Wu, Yu-Hsueh; Jeng, Jiiang-Huei
2018-04-01
Cemental tear is a special kind of root surface fracture, contributing to periodontal and periapical breakdown. However, it is a challenge for doctors to diagnose, resulting in delayed or improper treatment. We reviewed the predisposing factors, location, radiographic/clinical characteristics, diagnosis and treatments of cemental tears. From the literature, patients with cemental tear were mainly males, over 60 year-old. Possible predisposing factors include gender, age, tooth type, traumatic occlusal force and vital teeth. Cemental tears were common in upper and lower anterior teeth, single or multiple, and can be present in cervical, middle and apical third of roots. Morphology of cemental tears can be either piece-shaped or U-shaped. Clinically, cemental tear shows a unitary periodontal pocket and signs/symptoms mimicking localized periodontitis, apical periodontitis and vertical root fractures. Treatment of cemental tears include scaling, root planning, root canal treatment, periodontal/periapical surgery, guided tissue regeneration, bone grafting, and intentional replantation. Recurrence of cemental tear is possible especially when the fracture involves root apex. Extraction is recommended for teeth with poor prognosis. In conclusion, cemental tears can involve both periodontal and periapical area. Dentists should understand the predisposing factors and clinical features of cemental tears for early diagnosis/treatment to prevent bone loss/tooth extraction. Copyright © 2017. Published by Elsevier B.V.
Two types of peak emotional responses to music: The psychophysiology of chills and tears
Mori, Kazuma; Iwanaga, Makoto
2017-01-01
People sometimes experience a strong emotional response to artworks. Previous studies have demonstrated that the peak emotional experience of chills (goose bumps or shivers) when listening to music involves psychophysiological arousal and a rewarding effect. However, many aspects of peak emotion are still not understood. The current research takes a new perspective of peak emotional response of tears (weeping, lump in the throat). A psychophysiological experiment showed that self-reported chills increased electrodermal activity and subjective arousal whereas tears produced slow respiration during heartbeat acceleration, although both chills and tears induced pleasure and deep breathing. A song that induced chills was perceived as being both happy and sad whereas a song that induced tears was perceived as sad. A tear-eliciting song was perceived as calmer than a chill-eliciting song. These results show that tears involve pleasure from sadness and that they are psychophysiologically calming; thus, psychophysiological responses permit the distinction between chills and tears. Because tears may have a cathartic effect, the functional significance of chills and tears seems to be different. We believe that the distinction of two types of peak emotions is theoretically relevant and further study of tears would contribute to more understanding of human peak emotional response. PMID:28387335
Factors predicting rotator cuff retears: an analysis of 1000 consecutive rotator cuff repairs.
Le, Brian T N; Wu, Xiao L; Lam, Patrick H; Murrell, George A C
2014-05-01
The rate of retears after rotator cuff repair varies from 11% to 94%. A retear is associated with poorer subjective and objective clinical outcomes than intact repair. This study was designed to determine which preoperative and/or intraoperative factors held the greatest association with retears after arthroscopic rotator cuff repair. Cohort study; Level of evidence, 3. This study retrospectively evaluated 1000 consecutive patients who had undergone a primary rotator cuff repair by a single surgeon using an arthroscopic inverted-mattress knotless technique and who had undergone an ultrasound evaluation 6 months after surgery to assess repair integrity. Exclusion criteria included previous rotator cuff repair on the same shoulder, incomplete repair, and repair using a synthetic polytetrafluoroethylene patch. All patients had completed the modified L'Insalata Questionnaire and underwent a clinical examination before surgery. Measurements of tear size, tear thickness, associated shoulder injury, tissue quality, and tendon mobility were recorded intraoperatively. The overall retear rate at 6 months after surgery was 17%. Retears occurred in 27% of full-thickness tears and 5% of partial-thickness tears (P < .0001). The best independent predictors of retears were anteroposterior tear length (correlation coefficient r = 0.41, P < .0001), tear size area (r = 0.40, P < .0001), mediolateral tear length (r = 0.34, P < .0001), tear thickness (r = 0.29, P < .0001), age at surgery (r = 0.27, P < .0001), and operative time (r = 0.18, P < .0001). These factors produced a predictive model for retears: logit P = (0.039 × age at surgery in years) + (0.027 × tear thickness in %) + (1 × anteroposterior tear length in cm) + (0.76 × mediolateral tear length in cm) - (0.17 × tear size area in cm(2)) + (0.018 × operative time in minutes) -9.7. Logit P can be transformed into P, which is the chance of retears at 6 months after surgery. A rotator cuff retear is a multifactorial process with no single preoperative or intraoperative factor being overwhelmingly predictive of it. Nevertheless, rotator cuff tear size (tear dimensions, tear size area, and tear thickness) showed stronger associations with retears at 6 months after surgery than did measures of tissue quality and concomitant shoulder injuries.
Hawk, Joyce; Shannon, Mary
2018-04-01
The incidence and prevalence of skin tears in long-term care (LTC) facilities has not been well established. To ascertain the point prevalence of reported skin tears, a retrospective review of incident reports was performed in 6 LTC facilities in western Pennsylvania from November 1, 2016 through December 31, 2016. Report data, including resident age; gender; mobility limitations; skin tear location, number, and cause (if known); occurrence time (7 am to 3 pm, 3 pm to 11 pm, or 11 pm to 7 am nursing shift); and history of previous skin tears, were abstracted. All data were entered into a statistical analysis program and analyzed using descriptive statistics. Period prevalence was used to determine prevalence rate; an independent t test was used to compare the presence of skin tears between genders. Differences between location and cause of skin tears were evaluated using a multinomial test of related proportions. A test of proportions was used to evaluate skin tear occurrence time (nursing shift) differences. The overall point prevalence rate was 9% (N = 1253 residents) ranging from 6 to 28 skin tears per facility. The average age of residents with a skin tear (n = 119) was 83.5 years. The majority (111, 93%) had mobility limitations. Falls accounted for 38 skin tears (31.9%), followed by propelling in a wheelchair (18, 15.1%; X2 =7.14; P = .008). Forearm skin tears (37, 31.1%) occurred significantly more frequently than lower leg skin tears (19, 16%; P = .016). Significantly more skin tears occurred during the 7 am to 3 pm shift (47, 39.5%) and 3 pm to 11 pm shift (49, 41.2%) than during the 11 pm to 7 am shift (23, 19.3%; X2 = 5.78; P <.01). The results of this study confirm skin tears are a significant problem among elderly residents in LTC, especially because the reported rate is likely lower than the actual rate. Research to further elucidate the incidence and prevalence of skin tears and associated risk factors is needed to help develop evidence-based risk assessment, classification systems, treatment guidelines, and preventive measures.
Kandhavelu, Jeyalakshmi; Demonte, Naveen Luke; Namperumalsamy, Venkatesh Prajna; Prajna, Lalitha; Thangavel, Chitra; Jayapal, Jeya Maheshwari; Kuppamuthu, Dharmalingam
2017-01-30
Aspergillus flavus and Fusarium sp. are primary causative agents of keratitis that results in corneal tissue damage leading to vision loss particularly in individuals from the tropical parts of the world. Proteins in the tear film collected from control and keratitis patients was profiled and compared. A total of 1873 proteins from control and 1400 proteins from patient tear were identified by mass spectrometry. While 847 proteins were found to be glycosylated in the patient tear, only 726 were glycosylated in control tear. And, some of the tear proteins showed alterations in their glycosylation pattern after infection. Complement system proteins, proteins specific for neutrophil extracellular traps and proteins involved in would healing were found only in the patient tear. The presence of these innate immune system proteins in the tear film of patients supports the previous data indicating the involvement of neutrophil and complement pathways in antifungal defense. High levels of wound healing proteins in keratitis patient tear implied activation of tissue repair during infection. The early appearance of the host defense proteins and wound healing response indicates that tear proteins could be used as an early marker system for monitoring the progression of pathogenesis. Identification of negative regulators of the above defense pathways in keratitis tear indicates an intricate balance of pro and anti-defense mechanisms operating in fungal infection of the eye. Tear proteins from control and mycotic keratitis patients were separated into glycoproteins and non-glycosylated proteins and then identified by mass spectrometry. Tear proteins from keratitis patients showed alteration in the glycosylation pattern indicating the alteration of glycosylation machinery due to infection. Neutrophil extracellular traps specific proteins, complement pathway proteins, as well as wound healing proteins, were found only in patient tear showing the activation of antifungal defense in the patient tear. Negative regulators of these defense pathways were also found in patient tear indicating a fine balance between pathogen clearance and host tissue destruction during fungal infection depending upon the individual specific host - pathogen interaction. This understanding could be used to predict the progression and outcome of infection. Copyright © 2016 Elsevier B.V. All rights reserved.
Concentrations of MUC16 and MUC5AC using three tear collection methods
Nichols, Jason J.
2017-01-01
Purpose To determine the optimal tear collection method for analysis of ocular surface mucins MUC5AC and MUC16. Methods Fifteen subjects without ocular surface disease were recruited. Subjects presented for tear collection on three separate days for three different tear collection methods with the order of method randomized. Methods used to collect tears from right and left eyes included Schirmer’s strip, basal tear collection, and flush tear collection. All samples from the right eyes were individually analyzed for MUC5AC whereas the left eye samples were individually analyzed for MUC16. For each individual sample, 10 μg of protein were loaded per lane into a 1% (w/v) agarose gel and run in electrophoresis buffer for 2 h. After overnight capillary transfer, membranes were incubated with either MUC5AC antibody CLH2 or MUC16 antibody OC125 for western blot analysis. Blots were developed with enhanced chemiluminescence (ECL) and signals captured with the Odyssey Fc (LI-COR). The relative amounts of MUC5AC and MUC16 were quantified with densitometry using software and compared for statistically significant differences between tear collection methods using the Kruskal–Wallis test in SPSS 22 and GraphPad Prism 7.02. Dunn’s multiple comparisons test was used for pairwise post-hoc comparisons. Results Samples containing less than 10 μg of total protein were not used for analysis which left eight samples (out of 45) unusable. The calculated MUC5AC median signal intensities from Schirmer’s strip, basal tears, and flush tears were 2.86 (n = 15, the interquartile range [IQR] = 2.54–3.21), 1.65 (n = 14, IQR = 1.34–3.1), and 1.67 (n = 9, IQR = 1.42–1.72), respectively (H = 9.5, p = 0.009). Post-hoc pairwise comparisons showed a statistically significant difference between Schirmer’s strip and flush tears (p = 0.01). The calculated MUC16 median signal intensities from Schirmer’s strip, basal tears, and flush tears were 1.88 (n = 14, IQR = 1.43–2.61), 5.24 (n = 15, IQR = 4.16–6.21), and 2.45 (n = 7, IQR = 1.85–2.48), respectively (H = 18.1, p = 0.001). Post-hoc pairwise comparison showed statistically significant differences between basal tears and Schirmer’s strip (p = 0.0003) and between basal tears and flush tears (p = 0.006). Conclusions MUC5AC and MUC16 are present in human tear fluid and can be captured using various tear collection methods. Although basal tear collection yielded the highest relative concentration of MUC16, Schirmer’s strip tear collection yielded the highest MUC5AC concentration. Therefore, the tear collection method chosen depends on the mucin of interest. PMID:28761326
Chung, Seok Won; Kim, Jae Yoon; Yoon, Jong Pil; Lyu, Seong Hwa; Rhee, Sung Min; Oh, Se Bong
2015-03-01
The healing failure rate is high for partial-thickness or small full-thickness rotator cuff tears. To retrospectively evaluate and compare outcomes after arthroscopic repair of high-grade partial-thickness and small full-thickness rotator cuff tears and factors affecting rotator cuff healing. Cohort study; Level of evidence, 3. Included in the study were 55 consecutive patients (mean age, 57.9 ± 7.2 years) who underwent arthroscopic repair for high-grade partial-thickness (n = 34) and small full-thickness (n = 21) rotator cuff tears. The study patients also underwent magnetic resonance imaging (MRI) preoperatively and computed tomography arthrography (CTA) at least 6 months postoperatively, and their functional outcomes were evaluated preoperatively and at the last follow-up (>24 months). All partial-thickness tears were repaired after being converted to full-thickness tears; thus, the repair process was almost the same as for small full-thickness tears. The tendinosis of the torn tendon was graded from the MRI images using a 4-point scale, and the reliabilities were assessed. The outcomes between high-grade partial-thickness tears that were converted to small full-thickness tears and initially small full-thickness tears were compared, and factors affecting outcomes were evaluated. The inter- and intraobserver reliabilities of the tendinosis grade were good (intraclass correlation coefficient, 0.706 and 0.777, respectively). Failure to heal as determined by CTA was observed in 12 patients with a high-grade partial-thickness tear (35.3%; complete failure in 4 and partial failure in 8) and in 3 patients with a small full-thickness tear (14.3%; complete failure in 1 and partial failure in 2). The patients with high-grade partial-thickness rotator cuff tears showed a higher tendinosis grade than did those with small full-thickness tears (P = .014), and the severity of the tendinosis was related to the failure to heal (P = .037). Tears with a higher tendinosis grade showed a 7.64-times higher failure rate (95% CI, 1.43-36.04) than did those with a lower tendinosis grade (P = .013). All functional outcome scores improved after surgery (all P < .001); however, there was no difference between groups. The high-grade partial-thickness rotator cuff tears showed more severe tendinosis compared with the small full-thickness tears in this study. Contrary to previous impressions that tear size or fatty infiltration is the factor that most influences healing, tendinosis severity assessed by preoperative MRI was the only factor associated with failure to heal, given the numbers available for analysis, in patients with partial-thickness and small full-thickness rotator cuff tears. Surgeons should pay more attention to tendon quality during repair surgery or rehabilitation in smaller rotator cuff tears, especially in high-grade partial-thickness tears with severe tendinosis. © 2014 The Author(s).
Tear exchange and contact lenses: a review.
Muntz, Alex; Subbaraman, Lakshman N; Sorbara, Luigina; Jones, Lyndon
2015-01-01
Tear exchange beneath a contact lens facilitates ongoing fluid replenishment between the ocular surface and the lens. This exchange is considerably lower during the wear of soft lenses compared with rigid lenses. As a result, the accumulation of tear film debris and metabolic by-products between the cornea and a soft contact lens increases, potentially leading to complications. Lens design innovations have been proposed, but no substantial improvement in soft lens tear exchange has been reported. Researchers have determined post-lens tear exchange using several methods, notably fluorophotometry. However, due to technological limitations, little remains known about tear hydrodynamics around the lens and, to-date, true tear exchange with contact lenses has not been shown. Further knowledge regarding tear exchange could be vital in aiding better contact lens design, with the prospect of alleviating certain adverse ocular responses. This article reviews the literature to-date on the significance, implications and measurement of tear exchange with contact lenses. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.
Prevalence of triceps tendon tears on MRI of the elbow and clinical correlation.
Koplas, Monica C; Schneider, Erika; Sundaram, Murali
2011-05-01
Triceps tendon injuries are reported to be very rare. To our knowledge, there have been no studies describing its prevalence or injury patterns on MR imaging. The purpose of this retrospective study was to determine the prevalence and patterns of triceps injuries based on a large series of consecutive MR examinations. Clinical correlation was obtained. From 801 consecutive elbow MR examinations over a 15-year period, 28 patients with 30 triceps tendon injuries were identified and graded as partial tendon tear and complete tendon tear. The patients' medical records were reviewed to determine age, gender, cause of tears, and management. The prevalence of triceps tendon injuries was 3.8%. There were 5 women and 23 men with partial or complete tears (mean age: 46.6 years; range: 2.7 to 75.1 years). The most common injury was partial tear, found in 18 patients. There were 10 patients with 12 complete tears (2 had re-torn following surgical repair). A tear was suspected in 12 out 28 (43%) patients prior to the MRI. The most common presenting symptom was pain. The most common cause was athletic injury (8 patients [29%], including weightlifting [2 patients]). Tendon tear was found to be a complication of infection in 6 patients, and in 3 patients the tears were a complication of steroid use. Thirteen tendon tears were surgically repaired (8 of these were complete tears). Triceps tendon injury is not as rare as commonly reported and may often be clinically underdiagnosed.
The Changes of Tear Status after Conventional and Wavefront-Guided IntraLASIK
Foo, Say Kiang; Kaur, Sharanjeet; Abd Manan, Faudziah; Low, Aloysius Joseph
2011-01-01
Background: IntraLASIK is a LASIK surgery that involved IntraLase femtosecond laser for the corneal flap creating. The objective of this research was to investigate and compare the changes in tear status at 1 and 3 months after undergoing conventional IntraLASIK with Bausch & Lomb PlanoScan (PS) algorithm, Bausch & Lomb Zyoptix Tissue Saving (ZTS) algorithm, and wavefront-guided (WG) IntraLASIK with VISX CustomVue. Methods: Tear status of 36 patients who were divided into 3 groups depending on the type of IntraLASIK they underwent (PS, n = 13; ZTS, n = 9; WG, n = 14) was evaluated. Tear status was determined by classifying the category of the thickness of pre-corneal tear lipid layer, non-invasive tear break-up time, and tear meniscus height. Repeated measures analysis of variance (ANOVA) and one way ANOVA were used for the statistical analyses. Results: The category of the thickness of tear lipid layer, non-invasive tear break up time and tear meniscus height were neither significantly changed after IntraLASIK for all groups nor showed significant difference among groups at 1 and 3 months post-IntraLASIK (P > 0.05). Blinking rate and palpebral aperture also had no significant changed after IntraLASIK. Conclusion: Both conventional (PS and ZTS) and WG IntraLASIK did not affect tear status up to 3 months post-IntraLASIK. WG IntraLASIK did not show superiority in preserving tear status 1 and 3 months post-surgery compared with conventional IntraLASIK. PMID:22135584
Munro, Emma L; Hickling, Donna F; Williams, Damian M; Bell, Jack J
2018-05-24
Skin tears cause pain, increased length of stay, increased costs, and reduced quality of life. Minimal research reports the association between skin tears, and malnutrition using robust measures of nutritional status. This study aimed to articulate the association between malnutrition and skin tears in hospital inpatients using a yearly point prevalence of inpatients included in the Queensland Patient Safety Bedside Audit, malnutrition audits and skin tear audits conducted at a metropolitan tertiary hospital between 2010 and 2015. Patients were excluded if admitted to mental health wards or were <18 years. A total of 2197 inpatients were included, with a median age of 71 years. The overall prevalence of skin tears was 8.1%. Malnutrition prevalence was 33.5%. Univariate analysis demonstrated associations between age (P ˂ .001), body mass index (BMI) (P < .001) and malnutrition (P ˂ .001) but not gender (P = .319). Binomial logistic regression analysis modelling demonstrated that malnutrition diagnosed using the Subjective Global Assessment was independently associated with skin tear incidence (odds ratio, OR: 1.63; 95% confidence interval, CI: 1.13-2.36) and multiple skin tears (OR 2.48 [95% CI 1.37-4.50]). BMI was not independently associated with skin tears or multiple skin tears. This study demonstrated independent associations between malnutrition and skin tear prevalence and multiple skin tears. It also demonstrated the limitations of BMI as a nutritional assessment measure. © 2018 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
González, Nerea; Iloro, Ibon; Durán, Juan A.; Elortza, Félix
2012-01-01
Purpose To characterize the tear film peptidome and low molecular weight protein profiles of healthy control individuals, and to evaluate changes due to day-to-day and individual variation and tear collection methods, by using solid phase extraction coupled to matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) profiling. Methods The tear protein profiles of six healthy volunteers were analyzed over seven days and inter-day and inter-individual variability was evaluated. The bilaterality of tear film and the effect of tear collection methods on protein profiles were also analyzed in some of these patients. MALDI-TOF MS analyses were performed on tear samples purified by using a solid phase extraction (SPE) method based on C18 functionalized magnetic beads for peptide and low molecular weight protein enrichment, focusing spectra acquisition on the 1 to 20 kDa range. Spectra were analyzed using principal component analysis (PCA) with MultiExperiment Viewer (TMeV) software. Volunteers were examined in terms of tear production status (Schirmer I test), clinical assessment of palpebral lids and meibomian glands, and a subjective OSD questionnaire before tear collection by a glass micro-capillary. Results Analysis of peptides and proteins in the 1–20 kDa range showed no significant inter-day differences in tear samples collected from six healthy individuals during seven days of monitoring, but revealed subtle intrinsic inter-individual differences. Profile analyses of tears collected from the right and left eyes confirmed tear bilaterality in four healthy patients. The addition of physiologic serum for tear sample collection did not affect the peptide and small protein profiles with respect to the number of resolved peaks, but it did reduce the signal intensity of the peaks, and increased variability. Magnetic beads were found to be a suitable method for tear film purification for the profiling study. Conclusions No significant variability in tear peptide and protein profiles below 20 kDa was found in healthy controls over a seven day period, nor in right versus left eye profiles from the same individual. Subtle inter-individual differences can be observed upon tear profiling analysis and confirm intrinsic variability between control subjects. Addition of physiologic serum for tear collection affects the proteome and peptidome in terms of peak intensities, but not in the composition of the profiles themselves. This work shows that MALDI-TOF MS coupled with C18 magnetic beads is an effective and reproducible methodology for tear profiling studies in the clinical monitoring of patients. PMID:22736947
DOE Office of Scientific and Technical Information (OSTI.GOV)
Muttalib, Siti Nadzirah Abdul, E-mail: sitinadzirah.amn@gmail.com; Othman, Nadras, E-mail: srnadras@usm.my; Ismail, Hanafi, E-mail: ihanafi@usm.my
This paper reports on the effect of filler loading on properties of natural rubber (NR)/attapulgite (ATP) composites. The NR/ATP composites were prepared by latex compounding method. It is called as masterbatch. The masterbatch was subsequently added to the NR through melt mixing process. The vulcanized NR/ATP composites were subjected to mechanical, swelling and morphological tests. All the results were compared with NR/ATP composites prepared by conventional system. The composites from masterbatch method showed better results compared to composites prepared by conventional method. They have higher tensile properties, elongation at break and tear strength. The images captured through scanning electron microscopymore » test revealed the improvement of tensile strength in masterbatch NR/ATP composites. It can be seen clearly that masterbatch NR/ATP have better filler dispersion compared to conventional method NR/ATP composites.« less
Zickfeld, Janis H; Schubert, Thomas W
2018-01-31
Recent work investigated the inter-individual functions of emotional tears in depth. In one study (Van de Ven, N., Meijs, M. H. J., & Vingerhoets, A. (2017). What emotional tears convey: Tearful individuals are seen as warmer, but also as less competent. British Journal of Social Psychology, 56(1), 146-160. Https://doi.org/10.1111/bjso.12162) tearful individuals were rated as warmer, and participants expressed more intentions to approach and help such individuals. Simultaneously, tearful individuals were rated as less competent, and participants expressed less intention to work with the depicted targets. While tearful individuals were perceived as sadder, perceived sadness mediated only the effect on competence, but not on warmth. We argue that tearful individuals might be perceived as warm because they are perceived as feeling moved and touched. We ran a pre-registered extended replication of Van de Ven et al. Results replicate the warmth and helping findings, but not the competence and work effects. The increase in warmth ratings was completely mediated by perceiving feeling moved and touched. Possible functions of feeling moved and touched with regard to emotional tears are discussed.
Lee, Ryan K L; Griffith, James F; Ng, Alex W H; Nung, Ryan C H; Yeung, David K W
2016-01-01
The purpose of this study was to assess the effects of traction during MR arthrography of the wrist on joint space widening, cartilage visibility, and detection of tears of the triangular fibrocartilage complex (TFCC) and intrinsic ligaments. A prospective study included 40 wrists in 39 patients (25 men, 14 women; mean age, 35 years). MR arthrography was performed with a 3-T MRI system with and without axial traction. Two radiologists independently measured wrist and carpal joint space widths and semiquantitatively graded articular cartilage visibility. Using conventional arthrography as the reference standard and working in consensus, they assessed for the presence of tears of the TFCC, lunotriquetral ligament (LTL), and scapholunate ligament (SLL). Visibility of a tear before traction was compared with visibility after traction. With traction, all joint spaces in the wrist and carpus were significantly widened (change, 0.15-1.01 mm; all p < 0.006). Subjective cartilage visibility of all joint spaces improved after traction (all p ≤ 0.048) except for that of the radioscaphoid space, which was well visualized even before traction. Conventional arthrography depicted 24 TFCC tears, seven LTL tears, and three SLL tears. The accuracy of tear detection improved after traction for the TFCC (98% after traction vs 83% before traction), the LTL (100% vs 88%), and the SLL (100% vs 95%). Tear visibility improved after traction for 54% of TFCC tears, 71% of LTL tears, and 66% of SLL tears. Wrist MR arthrography with axial traction significantly improved the visibility of articular cartilage and the detection and visibility of tears of the TFCC and intrinsic ligaments. The results favor more widespread use of traction during MR arthrography of the wrist.
Evaluating tear clearance rate with optical coherence tomography.
Garaszczuk, Izabela K; Mousavi, Maryam; Cervino Exposito, Alejandro; Bartuzel, Maciej M; Montes-Micó, Robert; Iskander, D Robert
2018-02-01
To assess the early-phase of tear clearance rate (TCR) with anterior segment optical coherence tomography (OCT) and to determine the association between TCR and other clinical measures of the tear film in a group of young subjects with different levels of tear film quality. TCR was classified as the percentage decrease of subject's inferior tear meniscus height 30s after instillation of 5μl 0.9% saline solution. Fifty subjects (32F and 18M) aged (mean±standard deviation) 25.5±4.3 years volunteered for the study. It consisted of a review of medical history, Ocular Surface Disease Index (OSDI) questionnaire, tear film osmolarity measurements, slit lamp examination and TCR estimation based on dynamic measurements of the lower tear meniscus with OCT. Estimates of TCR were contrasted against subject age and tear film measures commonly used for dry eye diagnosis, which includes OSDI score, fluorescein tear film break-up time (FBUT), tear meniscus height (TMH), blinking frequency, tear film osmolarity and corneal staining. The group mean TCR was 29±13% and 36±19% respectively after 30 and 60s margin after saline solution instillation. Statistically significant correlations were found between TCR and FBUT (r 2 =0.319, p<0.001), blinking frequency (r 2 =0.138, p<0.01), tear film osmolarity (r 2 =0.133, p<0.01) and subject's age (r 2 =0.095, p<0.05). Anterior segment optical coherence tomography allows following changes of tear meniscus morphology post saline solution instillation and evaluating the TCR. OCT based TCR might be used as additional measure of the lacrimal functional unit. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Predicting Rotator Cuff Tears Using Data Mining and Bayesian Likelihood Ratios
Lu, Hsueh-Yi; Huang, Chen-Yuan; Su, Chwen-Tzeng; Lin, Chen-Chiang
2014-01-01
Objectives Rotator cuff tear is a common cause of shoulder diseases. Correct diagnosis of rotator cuff tears can save patients from further invasive, costly and painful tests. This study used predictive data mining and Bayesian theory to improve the accuracy of diagnosing rotator cuff tears by clinical examination alone. Methods In this retrospective study, 169 patients who had a preliminary diagnosis of rotator cuff tear on the basis of clinical evaluation followed by confirmatory MRI between 2007 and 2011 were identified. MRI was used as a reference standard to classify rotator cuff tears. The predictor variable was the clinical assessment results, which consisted of 16 attributes. This study employed 2 data mining methods (ANN and the decision tree) and a statistical method (logistic regression) to classify the rotator cuff diagnosis into “tear” and “no tear” groups. Likelihood ratio and Bayesian theory were applied to estimate the probability of rotator cuff tears based on the results of the prediction models. Results Our proposed data mining procedures outperformed the classic statistical method. The correction rate, sensitivity, specificity and area under the ROC curve of predicting a rotator cuff tear were statistical better in the ANN and decision tree models compared to logistic regression. Based on likelihood ratios derived from our prediction models, Fagan's nomogram could be constructed to assess the probability of a patient who has a rotator cuff tear using a pretest probability and a prediction result (tear or no tear). Conclusions Our predictive data mining models, combined with likelihood ratios and Bayesian theory, appear to be good tools to classify rotator cuff tears as well as determine the probability of the presence of the disease to enhance diagnostic decision making for rotator cuff tears. PMID:24733553
Effect of lipid-based dry eye supplements on the tear film in wearers of eye cosmetics.
Wang, Michael T M; Cho, Irene Sung Hee; Jung, Soo Hee; Craig, Jennifer P
2017-08-01
To compare the effects on tear film parameters and contamination in cosmetic eyeliner wearers, after single application of two lipid-based dry eye treatments: a lipid-containing lubricant eye drop and a phospholipid liposomal spray. Fifty participants were enrolled in a prospective, randomised, paired-eye, investigator-masked trial. Pencil eyeliner (Body Shop ® Crayon Eye Definer) was applied to the upper eyelid periocular skin of both eyes, anterior to the lash line. Baseline tear film quality was assessed fifteen minutes after eyeliner application. A lubricant drop (Systane ® Balance) was then applied to one eye (randomised), and liposomal spray (Tears Again ® ) to the contralateral eye. Tear film contamination, lipid layer grade, non-invasive tear film break-up time and tear evaporation rate were evaluated fifteen minutes post-treatment and compared to pre-treatment values. Pre-treatment measurements did not differ between eyes assigned to lubricant drop and liposomal spray. Tear film contamination was observed in a greater proportion of eyes following both treatments (both p<0.05), with no significant difference between treatments (p=0.41). Both treatments improved lipid layer thickness (both p≤0.01), but effected no significant change in non-invasive tear film break-up time or tear evaporation rate (all p>0.05). Changes in tear film parameters did not differ between treatments (all p>0.05). Both the lipid-containing lubricant eye drop and phospholipid liposomal spray result in clinically apparent tear film contamination in eyeliner cosmetic wearers. Although both treatments effected an increase in lipid layer thickness, neither displayed clinical efficacy in improving tear film stability. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Kan, Emrah; Kan, Elif K; Okuyucu, Ali
2017-08-30
To compare the central corneal thickness (CCT), intraocular pressure (IOP), and tear insulin-like growth factor 1 (IGF-1) levels between patients with acromegaly and a control group and to evaluate the possible effect of tear IGF-1 and duration of the disease on CCT and IOP. We included 31 patients with acromegaly (study group) and 40 age- and sex-matched controls in the study. Patients with acromegaly were divided into 2 subgroups based on disease status (active/inactive). All participants underwent complete ophthalmologic evaluation including CCT and IOP values. Basal tear samples were collected from both groups and tear IGF-1 levels were measured. The CCT, IOP, and tear IGF-1 levels were compared between groups and subgroups and the association between tear IGF-I levels and ocular parameters (CCT, IOP) and disease duration were also evaluated. Central corneal thickness, IOP, and tear IGF-1 levels did not show a significant difference between study and control groups. We also did not find a significant difference in terms of CCT, IOP, or tear IGF-1 levels between subgroups of patients. Correlation analysis did not show an association between the duration of disease and tear IGF-1 levels with CCT or IOP. There was no significant difference in tear IGF-1 levels between patients with acromegaly and controls. Additionally, there was no correlation between disease duration and tear IGF-1 levels with CCT or IOP levels. This lack of association may suggest that tear IGF-1 levels might not have an effect on CCT or IOP findings in patients with acromegaly.
Full-thickness tears of the supraspinatus tendon: A three-dimensional finite element analysis.
Quental, C; Folgado, J; Monteiro, J; Sarmento, M
2016-12-08
Knowledge regarding the likelihood of propagation of supraspinatus tears is important to allow an early identification of patients for whom a conservative treatment is more likely to fail, and consequently, to improve their clinical outcome. The aim of this study was to investigate the potential for propagation of posterior, central, and anterior full-thickness tears of different sizes using the finite element method. A three-dimensional finite element model of the supraspinatus tendon was generated from the Visible Human Project data. The mechanical behaviour of the tendon was fitted from experimental data using a transversely isotropic hyperelastic constitutive model. The full-thickness tears were simulated at the supraspinatus tendon insertion by decreasing the interface area. Tear sizes from 10% to 90%, in 10% increments, of the anteroposterior length of the supraspinatus footprint were considered in the posterior, central, and anterior regions of the tendon. For each tear, three finite element analyses were performed for a supraspinatus force of 100N, 200N, and 400N. Considering a correlation between tendon strain and the risk of tear propagation, the simulated tears were compared qualitatively and quantitatively by evaluating the volume of tendon for which a maximum strain criterion was not satisfied. The finite element analyses showed a significant impact of tear size and location not only on the magnitude, but also on the patterns of the maximum principal strains. The mechanical outcome of the anterior full-thickness tears was consistently, and significantly, more severe than that of the central or posterior full-thickness tears, which suggests that the anterior tears are at greater risk of propagating than the central or posterior tears. Copyright © 2016 Elsevier Ltd. All rights reserved.
Shah, Shivam A; Kormpakis, Ioannis; Cavinatto, Leonardo; Killian, Megan L; Thomopoulos, Stavros; Galatz, Leesa M
2017-12-01
Large rotator cuff tear size and advanced muscle degeneration can affect reparability of tears and compromise tendon healing. Clinicians often rely on direct measures of rotator cuff tear size and muscle degeneration from magnetic resonance imaging (MRI) to determine whether the rotator cuff tear is repairable. The objective of this study was to identify the relationship between gene expression changes in rotator cuff muscle degeneration to standard data available to clinicians. Radiographic assessment of preoperative rotator cuff tear severity was completed for 25 patients with varying magnitudes of rotator cuff tears. Tear width and retraction were measured using MRI, and Goutallier grade, tangent (tan) sign, and Thomazeau grade were determined. Expression of myogenic-, adipogenic-, atrophy-, and metabolism-related genes in biopsied muscles were correlated with tear width, tear retraction, Goutallier grade, tan sign, and Thomazeau grade. Tear width positively correlated with Goutallier grade in both the supraspinatus (r = 0.73) and infraspinatus (r = 0.77), along with tan sign (r = 0.71) and Thomazeau grade (r = 0.68). Decreased myogenesis (Myf5), increased adipogenesis (CEBPα, Lep, Wnt10b), and decreased metabolism (PPARα) correlated with radiographic assessments. Gene expression changes suggest that rotator cuff tears lead to a dramatic molecular response in an attempt to maintain normal muscle tissue, increase adipogenesis, and decrease metabolism. Fat accumulation and muscle atrophy appear to stem from endogenous changes rather than from changes mediated by infiltrating cells. Results suggest that chronic unloading of muscle, induced by rotator cuff tear, disrupts muscle homeostasis. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2808-2814, 2017. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Mayes, Susan; Ferris, April-Rose; Smith, Peter; Garnham, Andrew; Cook, Jill
2016-07-01
To compare the frequency of atraumatic ligamentum teres (LT) tear in professional ballet dancers with that of athletes, and to determine the relationship with clinical and imaging findings. Forty-nine male and female professional ballet dancers (98 hips) and 49 age and sex-matched non-dancing athletes (98 hips) completed questionnaires on hip symptoms and physical activity levels, underwent hip rotation range of movement (ROM) and hypermobility testing, and 3.0-Tesla magnetic resonance imaging (3 T MRI) on both hips to detect LT tears, acetabular labral tears, and articular cartilage defects, and to measure the lateral centre edge angles (LCE). A higher frequency of LT tear was found in dancers (55 %) compared with athletes (22 %, P = 0.001). The frequency and severity of LT tears in dancers increased with older age (P = 0.004, P = 0.006, respectively). The Hip and Groin Outcome Score (HAGOS) pain scores or hip rotation ROM did not differ significantly among participants with normal, partial, or complete tears of LT (P > 0.01 for all). Neither the frequency of generalised joint hypermobility (P = 0.09) nor the LCE angles (P = 0.32, P = 0.16, left and right hips respectively) differed between those with and those without LT tear. In most hips, LT tear co-existed with either a labral tear or a cartilage defect, or both. The higher frequency of atraumatic LT tears in professional ballet dancers suggests that the LT might be abnormally loaded in ballet, and caution is required when evaluating MRI, as LT tears may be asymptomatic. A longitudinal study of this cohort is required to determine if LT tear predisposes the hip joint to osteoarthritis.
Patient acceptability of tear collection in the primary healthcare setting.
Quah, Joanne Hui Min; Tong, Louis; Barbier, Sylvaine
2014-04-01
The primary healthcare setting is well placed for health screening. Tear fluid composition gives valuable information about the eye and systemic health, and there is now significant interest in the potential application of tears as a tool for health screening; however, the acceptability of tear collection in the primary healthcare setting as compared with other methods of human sample collection has not been previously addressed. The objective of this study was to evaluate the patient acceptability of tear collection in a primary healthcare setting. This was a cross-sectional study on 383 adult patients seeking primary healthcare, who were not diabetic and were not attending for an eye-related complaint. Tear collection was done using Schirmer strips, and an interviewer-administered questionnaire was conducted to collate information on the pain score (0-10) of the Schirmer tear collection, as well as to score the pain associated with their previous experience of antecubital venous puncture and finger prick test. The pain score for Schirmer tear collection was significantly lower (p < 0.001) than antecubital venous puncture but higher (p < 0.001) than finger prick. The pain scores for all three procedures were significantly higher in participants of younger age, female gender, and higher education level. Among the participants, 70% did not mind their tears being collected to screen for eye problems, whereas only 38% did not mind this procedure being performed for general health screening. Nevertheless, 69% of the participants preferred tear to urine collection, and 74% of participants preferred tear to blood collection. Tear collection using Schirmer strips is a highly acceptable form of investigation that has the potential for use in health screening in the primary healthcare setting. This study has implications on using tear collection as a method of ocular and systemic health screening in the primary healthcare setting.
Qiu, Weiqiang; Liu, Ziyuan; Zhang, Zhihong; Ao, Mingxin; Li, Xuemin; Wang, Wei
2012-01-01
This study aimed to compare the effects of treatment with punctal plugs versus artificial tears on visual function and tear film stability for dry eye. A total of 56 consecutive eyes of 28 dry eye patients observed at our clinic from May to October in 2009 were divided into two groups. One group (32 eyes of 16 patients) was treated with artificial tears, and punctal plugs were used in the other group (24 eyes of 12 patients). A questionnaire was used in these patients before treatment and was repeated 2 weeks after treatment. Fluorescent staining for tear film break-up time (BUT), the Schirmer test I (STI), and contrast sensitivity was performed at the same time. The questionnaire indicated that all patients complained about the uncomfortable symptoms associated with dry eye. These symptoms were relieved after the application of artificial tears or punctal plugs, and there was no significant difference between these two groups. We found that the corneal fluorescent staining disappeared after treatment. The BUT was improved significantly after treatment in both groups, but the improvement was greater in patients who received punctal plugs than those that received artificial tears. There was no remarkable change in the STI in the artificial tears group, but a significant change was observed in the punctal plugs group. The contrast sensitivities were greatly improved in simulated daylight, night, and glare disability conditions after treatment with artificial tears and punctal plugs. However, the changes in contrast sensitivity did not significantly differ between groups. Both artificial tears and punctal plugs relieved dry eye symptoms, repaired corneal lesions, enhanced tear film stability, and improved contrast sensitivity. Punctal plugs could improve tear film stability and elongate the BUT better than artificial tears.
Tear-Duct Obstruction and Surgery
... Staying Safe Videos for Educators Search English Español Tear-Duct Obstruction and Surgery KidsHealth / For Parents / Tear- ... year old with little or no treatment. About Tear Ducts Our eyes are continually exposed to dust, ...
... JavaScript. Watery eyes means you have too many tears draining from the eyes. Tears help keep the surface of the eye moist. ... the eye. Causes Your eyes are always making tears. These tears leave the eye through a small ...
NASA Astrophysics Data System (ADS)
Wang, Juan; Wang, Jiteng; Li, Yajiang; Zheng, Deshuang
2015-07-01
The brazing of Mo-Cu composite and 304 stainless steel was carried out in vacuum with Ni-Cr-P filler metal at 980 °C for 20 min. Microstructure in Mo-Cu/304 stainless steel joint was investigated by field-emission scanning electron microscope (FE-SEM) with energy dispersive spectrometer (EDS) and shear strength was measured by shearing test. The results indicate that shear strength of the Mo-Cu/304 stainless steel joint is about 155 MPa. There forms eutectic structure of γ-Ni solid solution with Ni3P in the braze seam. Ni-Cu(Mo) and Ni-Fe solid solution are at the interface beside Mo-Cu composite and 304 stainless steel, respectively. Shear fracture exhibits mixed ductile-brittle fracture feature with trans-granular fracture, ductile dimples and tearing edges. Fracture originates from the interface between brazing seam and Mo-Cu composite and it propagates to the braze seam due to the formation of brittle Ni5P2 and Cr3P precipitation.
McMonnies, Charles W
2017-12-01
This review examines the evidence for and significance of pre-conjunctival tear temperature being higher than central pre-corneal temperature with associated more rapid evaporation of warmer pre-conjunctival tears in normal eyes but especially in hyperemic dry eye disease. PubMed searches using the terms "evaporative dry eye," "conjunctival tear evaporation," "tear evaporation," and "dry eye conjunctival hyperemia" indicated 157, 49, 309, and 96 potentially relevant papers, respectively. Selections from these lists were the basis for examining the significance of the evidence relevant to pre-conjunctival tear layer temperature and evaporation. There is evidence supporting an amplifying inflammatory and para-inflammatory hyperemia dry eye cascade, which increases pre-conjunctival tear temperature and the risk of accelerated pre-conjunctival tear evaporation with exacerbated osmolarity elevation and inflammation. Dry eye cascade amplification is consistent with increases in symptoms and inflammatory as well as para-inflammatory hyperemia toward the end of the waking day. Apart from age-related conjunctivochalasis, dry eye-related conjunctival epithelial cell pathology including reduced goblet cell numbers and associated mucin deficiency, squamous metaplasia, and increased separation of cell layers could help to destabilize tears and facilitate evaporation as part of an amplifying cascade. Greater difficulty in assessing conjunctival tear break up may contribute to an underestimation of a role for faster evaporation of pre-conjunctival tears in dry eye disease and help explain any non-correspondence between symptoms and corneal signs of dry eye disease. Success with anti-inflammatory therapies for dry eye disease may be at least partly due to reductions in conjunctival hyperemia and deamplification of evaporative cascades. Conjunctival inflammatory hyperemia in other diseases may contribute to accelerated pre-conjunctival tear evaporation and the risk of tear-deficiency- associated exacerbation of those diseases including impaired responses to therapeutic approaches to them. Similarly, postsurgical conjunctival inflammation and associated acceleration of tear evaporation could contribute to delayed wound healing.
Eperon, Simone; Berguiga, Marouen; Ballabeni, Pierluigi; Guex-Crosier, Catherine; Guex-Crosier, Yan
2014-09-01
To prospectively investigate patients with seasonal allergic conjunctivitis (SAC) during the pollen season and test associations between tears total IgE, eotaxin concentrations, and SAC severity. Enrolled patients presented ocular symptoms and clinical signs of SAC at the time of presentation. Ocular itching, hyperaemia, chemosis, eyelid swelling, and tearing were scored, and the sum of these scores was defined as the clinical score. Conjunctival papillae were separately graded. We measured eotaxin concentration in tears by an enzyme-linked immunosorbent assay (ELISA) and total tear IgE by Lacrytest strip. Among thirty patients (30 eyes), 11 showed neither tear IgE nor tear eotaxin, while 15 out of 19 patients with positive IgE values presented a positive amount of eotaxin in their tears (Fisher's test: p < 0.001). The mean eotaxin concentration was 641 ± 154 (SEM) pg/ml. In patients with no amount of tear IgE, we observed a lower conjunctival papilla grade than in patients whose tears contained some amount of IgE (trend test: p = 0.032). In the 15 patients whose tear eotaxin concentration was null, tear IgE concentration was 5.3 ± 3.5 arbitrary units; in the other 15 patients whose eotaxin was positive, IgE reached 21 ± 4.3 arbitrary U (Mann-Whitney: p < 0.001). We measured 127 ± 47 pg/ml eotaxin in patients with no history of SAC but newly diagnosed as suffering from SAC, and 852 ± 218 pg/ml eotaxin in patients with a known SAC (p = 0.008). In contrast, tear IgE concentrations of both groups did not differ statistically significantly (p = 0.947). If IgE and eotaxin secreted in tears are major contributors in SAC pathogenesis, they however act at different steps of the process.
Atzei, A; Luchetti, R; Garagnani, L
2017-05-01
The classical definition of 'Palmer Type IB' triangular fibrocartilage complex tear, includes a spectrum of clinical conditions. This review highlights the clinical and arthroscopic criteria that enable us to categorize five classes on a treatment-oriented classification system of triangular fibrocartilage complex peripheral tears. Class 1 lesions represent isolated tears of the distal triangular fibrocartilage complex without distal radio-ulnar joint instability and are amenable to arthroscopic suture. Class 2 tears include rupture of both the distal triangular fibrocartilage complex and proximal attachments of the triangular fibrocartilage complex to the fovea. Class 3 tears constitute isolated ruptures of the proximal attachment of the triangular fibrocartilage complex to the fovea; they are not visible at radio-carpal arthroscopy. Both Class 2 and Class 3 tears are diagnosed with a positive hook test and are typically associated with distal radio-ulnar joint instability. If required, treatment is through reattachment of the distal radio-ulnar ligament insertions to the fovea. Class 4 lesions are irreparable tears due to the size of the defect or to poor tissue quality and, if required, treatment is through distal radio-ulnar ligament reconstruction with tendon graft. Class 5 tears are associated with distal radio-ulnar joint arthritis and can only be treated with salvage procedures. This subdivision of type IB triangular fibrocartilage complex tear provides more insights in the pathomechanics and treatment strategies. II.
Interferometric measurements of the tear film irregularities on the human cornea
NASA Astrophysics Data System (ADS)
Szczesna, Dorota H.; Jaronski, Jaroslaw; Kasprzak, Henryk T.; Stenevi, Ulf
2005-09-01
The pre-ocular tear film is the most anterior refractive surface of the eye. Its stability plays an important role in the condition of vision from the optical and physiological point of view. If the eye is opened for a significantly long time or suffers from an anormalities in tear production, there appear isolated dry islands - break-ups - with a random distribution in the continuous lacrimal film. We applied an interferometric method - Lateral Shearing Technique for investigating the tear film stability and the smoothness of the tear film surface. This method is non-invasive and it is characterised by the high accuracy and sensitivity. Interferometry allows dynamic measurements of the tear film stability in real time by observation of interference fringes. The evaporation of tears and appearance of the breakups causes changes in the fringe geometry. Fast Fourier Transform has been used for quantitative assessment of the fringe smoothness and as a consequence of the tear film surface geometry. This paper presents the method used for quantitative evaluation of the tear film distribution on the cornea. Examples of interferograms recorded on eyes of patients with healthy eyes, suffering from dry eye syndrome and wearing contact lenses are also given. With our technique we were able to observe distinct differences in stability of the tear film between healthy and dry eyes, and the tear film on contact lenses.
Bone mineralization changes of the glenoid in shoulders with symptomatic rotator cuff tear.
Harada, Yohei; Yokoya, Shin; Akiyama, Yuji; Mochizuki, Yu; Ochi, Mitsuo; Adachi, Nobuo
2018-06-06
Computed tomography osteoabsorptiometry (CTO) is a method to analyze the stress distribution in joints by measuring the subchondral bone density. The purpose of this study was to evaluate the bone mineralization changes of the glenoid in shoulders with rotator cuff tears by CTO and to evaluate whether rotator cuff tears are associated with stress changes in the glenoid. In total, 32 patients, who were diagnosed with unilateral rotator cuff tears and underwent arthroscopic rotator cuff repair, were enrolled in this study. They underwent CT scanning of both shoulders pre-operatively and the glenoid was evaluated using CTO. Hounsfield units (HU) in seven areas of the glenoid were compared between the affected and unaffected sides. The central area of the glenoid on the affected side had significantly lower HU than on the unaffected side among all patients. Focusing on the rotator cuff tear size and the subscapularis tendon, only patients with larger cuff tears or with subscapularis tendon tears showed significantly lower HU in the central area of the affected side. This study showed a decrease in bone mineralization density in the central glenoid in shoulders with rotator cuff tear. This change was observed in the case of larger cuff tears and subscapularis tendon tears. Our results help clarify the changes in stress distribution in the shoulder joint caused by symptomatic rotator cuff tears.
New testing options for diagnosing and grading dry eye disease.
Foulks, Gary N; Pflugfelder, Stephen C
2014-06-01
To describe new options for diagnosis and severity grading of dry eye disease. Perspective on technological advancements to identify tear dysfunction and their value in diagnosing and grading dry eye disease. Evidence is presented on new and evolving technologies to measure tear stability, composition, and meniscus height and their role in dry eye diagnosis and therapeutic efficacy grading is assessed. Evolving concepts regarding pathogenesis and new technologies to evaluate the tears and ocular surface have improved the ability to diagnose, classify, and grade the severity of dry eye disease. New technologies include noninvasive imaging of tear stability and tear meniscus height as a measure of tear volume and tear composition (osmolarity, lacrimal factors, inflammatory mediators, growth and differentiation factors). Approved tests, such as tear osmolarity and tear imaging, are being integrated into clinical practice and may eventually supplant certain traditional tests that have greater variability and less sensitivity. Other tests, such as molecular assays of tears and conjunctival cells, are currently being used in studies investigating pathogenesis and therapeutic mechanism of action. They may eventually translate to routine clinical practice. New technologies have emerged that can noninvasively evaluate the tears and measure disease-associated compositional changes. These tests are being integrated into clinical practice and therapeutic trials for diagnosis, classification, and severity grading of dry eye disease. Copyright © 2014 Elsevier Inc. All rights reserved.
Partial articular-sided rotator cuff tears: in situ repair versus tear completion prior to repair.
Sethi, Paul M; Rajaram, Arun; Obopilwe, Elifho; Mazzocca, Augustus D
2013-06-01
Uncertainty exists over the ideal surgical treatment method for partial articular-sided rotator cuff tears, with options ranging from debridement to in situ repair to tear completion prior to repair. The purpose of this study was to determine whether in situ repair was a viable biomechanical treatment option compared with tear completion prior to repair of partial articular-sided rotator cuff tears. Fourteen fresh-frozen cadaveric shoulders were dissected. Partial articular-sided tears were created and repaired using in situ repair or tear completion prior to the repair. Strain and displacement were measured at 45°, 60°, and 90° of glenohumeral abduction. Testing was performed with a load of 100 N applied for 30 cycles. Data from the biomechanical testing displayed 4 conditions that showed improved characteristics of in situ repair over completion and repair: bursal-sided strain anteriorly at 45°, bursal-sided strain anteriorly at 90°, bursal-sided displacement anteriorly at 45°, and bursal-sided displacement anteriorly at 90°. The data indicate that in situ repair is a viable biomechanical treatment option compared with tear completion prior to repair of partial articular-sided rotator cuff tears. When clinically appropriate, the in situ repair may offer some biomechanical advantages, with lower strain and displacement observed on the bursal side compared with tear completion prior to repair. Copyright 2013, SLACK Incorporated.
... of the nose (lacrimal sac). From there tears travel down a duct (the nasolacrimal duct) draining into your nose. Once in the nose, tears are reabsorbed. A blockage can occur at any point in the tear drainage system, from the puncta ...
Metabolomics and Trace Element Analysis of Camel Tear by GC-MS and ICP-MS.
Ahamad, Syed Rizwan; Raish, Mohammad; Yaqoob, Syed Hilal; Khan, Altaf; Shakeel, Faiyaz
2017-06-01
Camel tear metabolomics and elemental analysis are useful in getting the information regarding the components responsible for maintaining the protective system that allows living in the desert and dry regions. The aim of this study was to correlate that the camel tears can be used as artificial tears for the evaluation of dryness in the eye. Eye biomarkers of camel tears were analyzed by gas chromatography-mass spectroscopy (GC-MS) and inductively coupled plasma mass spectroscopy (ICP-MS). The major compounds detected in camel tears by GC-MS were alanine, valine, leucine, norvaline, glycine, cadaverine, urea, ribitol, sugars, and higher fatty acids like octadecanoic acid and hexadecanoic acid. GC-MS analysis of camel tears also finds several products of metabolites and its associated metabolic participants. ICP-MS analysis showed the presence of different concentration of elemental composition in the camel tears.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sabau, Adrian S; Mirmiran, Seyed; Glaspie, Christopher
Hot-tearing is a major casting defect that is often difficult to characterize, especially for multicomponent Al alloys used for cylinder head castings. The susceptibility of multicomponent Al-Cu alloys to hot-tearing during permanent mold casting was investigated using a constrained permanent mold in which the load and displacement was measured. The experimental results for hot tearing susceptibility are compared with those obtained from a hot-tearing criterion based temperature range evaluated at fraction solids of 0.87 and 0.94. The Cu composition was varied from approximately 5 to 8 pct. (weight). Casting experiments were conducted without grain refining. The measured load during castingmore » can be used to indicate the severity of hot tearing. However, when small hot-tears are present, the load variation cannot be used to detect and assess hot-tearing susceptibility.« less
Sphincter tears in primiparous women: Is age a factor?
BOWLING, C. Bryce; WHEELER, Thomas L.; GERTEN, Kimberly A.; CHAPMAN, Victoria R.; BURGIO, Kathryn L.; RICHTER, Holly E.
2011-01-01
Introduction and Hypothesis Anal sphincter tears during vaginal delivery may result in serious sequelae. We examined whether younger primiparous patients were at increased risk for sphincter tears during vaginal delivery. Methods Data from an obstetric automated record were analyzed. Primiparous women delivering term infants (n = 5,937) were included to test for an association between age and sphincter tear rates. Three age groups were considered: young adolescents (≤16 years), older adolescents (17-20 years) and adults (≥21 years). Results No significant difference was found in tear rates among age cohorts (9.2%, 8.0%, and 9.6% respectively; p = 0.12). Logistic regression modeling revealed that young adolescents were not more likely to have sphincter tears compared to older cohorts. Conclusions Younger adolescents may not be at increased risk of anal sphincter tears. Decisions regarding interventions to decrease sphincter tears during vaginal delivery should not be made on the basis of maternal age alone. PMID:18985267
Vyas, Dharmesh; Harner, Christopher D
2012-06-01
Root tears are a subset of meniscal injuries that result in significant knee joint pathology. Occurring on either the medial or lateral side, root tears are defined as radial tears or avulsions of the posterior horn attachment to bone. After a root tear, there is a significant increase in tibio-femoral contact pressure concomitant with altered knee joint kinematics. Previous cadaver studies from our institution have shown that root repair of the medial meniscus is successful in restoring joint biomechanics to within normal limits. Indications for operative management of meniscal root tears include (1) a symptomatic medial meniscus root tear with minimal arthritis and having failed non-operative treatment, and (2) a lateral root tear in associated with an ACL tear. In this review, we describe diagnosis, imaging, patient selection, and arthroscopic surgical technique of medial and lateral meniscus root injuries. In addition we highlight the pearls of repair technique, associated complications, post-operative rehabilitation regimen, and expected outcomes.
NASA Astrophysics Data System (ADS)
van Haaften, W. M.; Kool, W. H.; Katgerman, L.
2002-10-01
One of the major problems during direct chill (DC) casting is hot tearing. These tears initiate during solidification of the alloy and may run through the entire ingot. To study the hot tearing mechanism, tensile tests were carried out in semisolid state and at low strain rates, and crack propagation was studied in situ by scanning electron microscopy (SEM). These experimentally induced cracks were compared with hot tears developed in an AA5182 ingot during a casting trial in an industrial research facility. Similarities in the microstructure of the tensile test specimens and the hot tears indicate that hot tearing can be simulated by performing tensile tests at semisolid temperatures. The experimental data were compared with existing hot tearing models and it was concluded that the latter are restricted to relatively high liquid fractions because they do not take into account the existence of solid bridges in the crack.
Kaido, Minako; Kawashima, Motoko; Shigeno, Yuta; Yamada, Yoshiaki; Tsubota, Kazuo
2018-05-01
Complex mechanisms underlie dry eye (DE) symptom provocation. In particular, corneal hypersensitivity may provoke symptoms in short tear break-up time (BUT) DE characterized by tear film instability. We hypothesized that improved tear film stability may alleviate corneal sensitivity in patients with short tear BUT DE. Therefore, we investigated the effect of topical diquafosol tetrasodium (DQS) on corneal sensitivity in unstable tear film DE. This prospective, randomized study included 27 subjects (age: 39.1 ± 8.4 years; range: 25-59 years) with short tear BUT DE, defined based on the presence of DE symptoms and tear film instability. Subjects were randomly divided into DQS (3% DQS, 12 subjects) and artificial tear (AT; preservative-free AT, 15 subjects) groups. Subjects applied the medication 6 times a day for 5 weeks. The perception of touch (S-touch) and pain (S-pain) sensitivity was measured using a Cochet-Bonnet esthesiometer. Tear evaluation, corneal sensitivity, and DE symptoms were compared before and after DQS or AT administration. The correlation between the improvement degrees of corneal sensitivity and DE symptoms following medication was analyzed. DQS significantly improved tear BUT and tear meniscus height (TMH) scores (p < 0.05), while AT significantly improved tear BUT (p < 0.05) but not TMH score. Mean S-pain and DE symptom scores were lower after medication use in the DQS (S-pain and DE symptoms: p < 0.05) and AT groups (S-pain: p = 0.05; DE symptoms: p < 0.05). However, S-touch did not change significantly in either group. A positive correlation was observed between the improvement degrees of S-pain and DE symptoms in the overall subjects studied. Both DQS and AT alleviate corneal hypersensitivity and DE symptoms in eyes with short tear BUT DE. However, DQS seems to be more effective to adjust tear environment, leading to the normalization of corneal sensitivity and DE symptoms. UMIN Clinical Trials Registry Identifier, UMIN000014536.
A mass and solute balance model for tear volume and osmolarity in the normal and the dry eye.
Gaffney, E A; Tiffany, J M; Yokoi, N; Bron, A J
2010-01-01
Tear hyperosmolarity is thought to play a key role in the mechanism of dry eye, a common symptomatic condition accompanied by visual disturbance, tear film instability, inflammation and damage to the ocular surface. We have constructed a model for the mass and solute balance of the tears, with parameter estimation based on extensive data from the literature which permits the influence of tear evaporation, lacrimal flux and blink rate on tear osmolarity to be explored. In particular the nature of compensatory events has been estimated in aqueous-deficient (ADDE) and evaporative (EDE) dry eye. The model reproduces observed osmolarities of the tear meniscus for the healthy eye and predicts a higher concentration in the tear film than meniscus in normal and dry eye states. The differential is small in the normal eye, but is significantly increased in dry eye, especially for the simultaneous presence of high meniscus concentration and low meniscus radius. This may influence the interpretation of osmolarity values obtained from meniscus samples since they need not fully reflect potential damage to the ocular surface caused by tear film hyperosmolarity. Interrogation of the model suggests that increases in blink rate may play a limited role in compensating for a rise in tear osmolarity in ADDE but that an increase in lacrimal flux, together with an increase in blink rate, may delay the development of hyperosmolarity in EDE. Nonetheless, it is predicted that tear osmolarity may rise to much higher levels in EDE than ADDE before the onset of tear film breakup, in the absence of events at the ocular surface which would independently compromise tear film stability. Differences in the predicted responses of the pre-ocular tears in ADDE compared to EDE or hybrid disease to defined conditions suggest that no single, empirically-accessible variable can act as a surrogate for tear film concentration and the potential for ocular surface damage. This emphasises the need to measure and integrate multiple diagnostic indicators to determine outcomes and prognosis. Modelling predictions in addition show that further studies concerning the possibility of a high lacrimal flux phenotype in EDE are likely to be profitable.
Shi, Yue; Zhu, Minjia; Chang, Yu; Qiao, Huanyu; Liu, Yongmin
2016-12-28
This study is to investigate the influence of hemodynamics on Stanford type-A aortic dissection with different tear size and location, to provide some support for the relationships between the risks (rupture, reverse tearing and further tearing) and tear size and location for clinical treatment. Four numerical models of Stanford type-A aortic dissection were established, with different size and location of the tears. The ratio of the area between the entry and re-entry tears(RA) is various within the model; while, the size and the location of the re-entry in the distal descending aorta are fixed. In model A11 and A21, the entry tears are located near the ascending aorta. The RA in these models are 1 and 2, respectively; In the model B11 and B21, the entry tears are located near the proximal descending aorta and the RA in these models are again assigned to 1 and 2, respectively. Then hemodynamics in these models was solved with numerically and the flow patterns and loading distributions were investigated. The flow velocity of the true lumen in model A21, B21 is lower than that in A11, B11, respectively; the time-averaged wall shear stress (TAWSS) of the false lumen in model A21 and B21 is higher, and for ascending aorta false lumen, A11, A21 are higher than B11, B21, respectively. False lumen intimal wall pressure of A11, A21 are always higher than the true lumen ones. The variation of the RA can significantly affect the dynamics of blood within the aortic dissection. When the entry tear size is larger than the re-entry tear ones, the false lumen, proximal descending aorta and the wall near re-entry tear are prone to cracking. Entry tear location can significantly alter the hemodynamics of aortic dissection as well. When entry tear location is closer to proximal ascending aorta, false lumen continues to expand and compress the true lumen resulting in the true lumen reduction. For proximal ascending aorta, high pressure in false lumen predicts a higher risk of reverse tear.
Wei, Yi; Gadaria-Rathod, Neha; Epstein, Seth; Asbell, Penny
2013-12-23
To provide standard operating procedures (SOPs) for measuring tear inflammatory cytokine concentrations and to validate the resulting profile as a minimally invasive objective metric and biomarker of ocular surface inflammation for use in multicenter clinical trials on dry eye disease (DED). Standard operating procedures were established and then validated with cytokine standards, quality controls, and masked tear samples collected from local and distant clinical sites. The concentrations of the inflammatory cytokines in tears were quantified using a high-sensitivity human cytokine multiplex kit. A panel of inflammatory cytokines was initially investigated, from which four key inflammatory cytokines (IL-1β, IL-6, INF-γ, and TNF-α) were chosen. Results with cytokine standards statistically satisfied the manufacturer's quality control criteria. Results with pooled tear samples were highly reproducible and reliable with tear volumes ranging from 4 to 10 μL. Incorporation of the SOPs into clinical trials was subsequently validated. Tear samples were collected at a distant clinical site, stored, and shipped to our Biomarker Laboratory, where a masked analysis of the four tear cytokines was successfully performed. Tear samples were also collected from a feasibility study on DED. Inflammatory cytokine concentrations were decreased in tears of subjects who received anti-inflammatory treatment. Standard operating procedures for human tear cytokine assessment suitable for multicenter clinical trials were established. Tear cytokine profiling using these SOPs may provide objective metrics useful for diagnosing, classifying, and analyzing treatment efficacy in inflammatory conditions of the ocular surface, which may further elucidate the mechanisms involved in the pathogenesis of ocular surface disease.
The Relationship between Metabolic Syndrome, Its Components, and Dry Eye: A Cross-Sectional Study.
Erdur, Sevil Karaman; Aydin, Rukiye; Ozsutcu, Mustafa; Olmuscelik, Oktay; Eliacik, Mustafa; Demirci, Goktug; Kocabora, Mehmet Selim
2017-08-01
The aim of this study was to evaluate tear osmolarity and tear film function and ocular surface changes in patients with metabolic syndrome. 108 eyes of 64 patients with metabolic syndrome (group 1) and 110 eyes of 55 healthy individuals (group 2) were included in this cross-sectional study. All participants were evaluated using the Ocular Surface Disease Index (OSDI) questionnaire, Schirmer I test, tear film break-up time (TBUT), and tear osmolarity. Main outcome measures were Ocular Surface Disease Index (OSDI) questionnaire, Schirmer I test, tear film break-up time (TBUT), and tear osmolarity values. Tear osmolarity values and OSDI scores were significantly higher in group 1 (314.4 ± 19.1 mOsm and 38.9 ± 1.1, respectively) compared with group 2 (295 ± 14.3 mOsm and 18.69 ± 17.2, respectively) (p = 0.01 for both). The Schirmer test values and TBUT in group 1 (10 ± 3.7 mm and 14.8 ± 3.6 sec, respectively) were significantly lower compared with group 2 (16.8 ± 2.6 mm and 18.1 ± 0.5 sec, respectively) (p < 0.001 for both). There was significant correlation between tear osmolarity versus waist circumference and fasting blood glucose in the study group (r = 0.364, p = 0.04; and r = 0.542, p ≤ 0.001, respectively). This study showed that metabolic syndrome can influence tear osmolarity and tear film function. Patients with metabolic syndrome showed tear hyperosmolarity and tear film dysfunction.
Subregional effects of meniscal tears on cartilage loss over 2 years in knee osteoarthritis.
Chang, Alison; Moisio, Kirsten; Chmiel, Joan S; Eckstein, Felix; Guermazi, Ali; Almagor, Orit; Cahue, September; Wirth, Wolfgang; Prasad, Pottumarthi; Sharma, Leena
2011-01-01
Meniscal tears have been linked to knee osteoarthritis progression, presumably by impaired load attenuation. How meniscal tears affect osteoarthritis is unclear; subregional examination may help to elucidate whether the impact is local. This study examined the association between a tear within a specific meniscal segment and subsequent 2-year cartilage loss in subregions that the torn segment overlies. Participants with knee osteoarthritis underwent bilateral knee MRI at baseline and 2 years. Mean cartilage thickness within each subregion was quantified. Logistic regression with generalised estimating equations were used to analyse the relationship between baseline meniscal tear in each segment and baseline to 2-year cartilage loss in each subregion, adjusting for age, gender, body mass index, tear in the other two segments and extrusion. 261 knees were studied in 159 individuals. Medial meniscal body tear was associated with cartilage loss in external subregions and in central and anterior tibial subregions, and posterior horn tear specifically with posterior tibial subregion loss; these relationships were independent of tears in the other segments and persisted in tibial subregions after adjustment for extrusion. Lateral meniscal body and posterior horn tear were also associated with cartilage loss in underlying subregions but not after adjustment for extrusion. Cartilage loss in the internal subregions, not covered by the menisci, was not associated with meniscal tear in any segment. These results suggest that the detrimental effect of meniscal tears is not spatially uniform across the tibial and femoral cartilage surfaces and that some of the effect is experienced locally.
Complete vs partial-thickness tears of the posterior cruciate ligament: MR findings.
Patten, R M; Richardson, M L; Zink-Brody, G; Rolfe, B A
1994-01-01
We sought to define the MRI appearance of both complete and partial-thickness tears of the posterior cruciate ligament (PCL) and to describe patterns of injury and associated MRI findings. Three radiologists retrospectively reviewed MR images and medical records on 32 patients with PCL tears (15 complete, 17 partial) and correlated MRI findings to results of clinical testing and surgery. The PCL had indistinct margins in 27 (84%) of 32 patients and was abnormally thick in 25 (78%) patients. In 31 (97%) patients, the torn PCL showed increased signal intensity on both T1- and T2-weighted pulse sequences. Although there was no statistically significant difference between patients with complete tears and those with partial tears with regard to thickness, margination, and signal intensity of the PCL, MR images in patients with complete tears were more likely to show focal areas of ligamentous discontinuity (10 of 15 cases) (p = 0.01). Associated knee injuries were seen in 21 (66%) patients and were seen more frequently in patients with complete PCL tears (p = 0.015). Bony injury (n = 11, 34%) and tears of the medial collateral ligament (n = 13, 41%) and menisci (n = 10, 31%) were common. No specific pattern of bony injury was found. Posterior cruciate ligament tears can be diagnosed readily by multiplanar MRI using both morphological and signal intensity characteristics. Although differentiation between complete and partial-thickness PCL tears by MRI criteria alone is more problematic, complete tears are more likely to show focal areas of discontinuity and partial tears are more likely to show at least some intact fibers.
Age-related changes in the signal value of tears.
Zeifman, Debra M; Brown, Sarah A
2011-08-12
Emotional tears may be uniquely human and are an effective signal of distress in adults. The present study explored whether tears signal distress in younger criers and whether the effect of tears on observers is similar in magnitude across the life span. Participants rated photographs of crying infants, young children, and adults, with tears digitally removed or added. The effectiveness of tears in conveying sadness and eliciting sympathy was greatest for images of adults, intermediate for images of children, and least potent for images of infants. These findings suggest that the signal value of tears varies with the age of the crier. The results may shed light on the functional significance of crying at different stages of human development.
Time-dependent changes after latissimus dorsi transfer: tenodesis or tendon transfer?
Erşen, Ali; Ozben, Hakan; Demirhan, Mehmet; Atalar, Ata Can; Kapıcıoğlu, Mehmet
2014-12-01
Transfer of the latissimus dorsi tendon to the posterosuperior part of the rotator cuff is an option in active patients with massive rotator cuff tears to restore shoulder elevation and external rotation. However, it is unknown whether this treatment prevents progression of cuff tear arthropathy. The purpose of this study was to determine whether the observed improvement in shoulder function in the early postoperative period with latissimus dorsi tendon transfer for irreparable rotator cuff tears will be permanent or will deteriorate in the midterm period (at 1-5 years after surgery). During a 6-year period, we performed 11 latissimus dorsi tendon transfers in 11 patients for patients with massive, irreparable, chronic tears of the posterosuperior part of the rotator cuff (defined as > 5 cm supraspinatus and infraspinatus tendon tears with Goutallier Grade 3 to 4 fatty infiltration on MRI), for patients who were younger than 65 years of age, and had high functional demands and intact subscapularis function. No patients were lost to followup; minimum followup was 12 months (median, 33 months; range, 12-62 months). The mean patient age was 55 years (median, 53 years; range, 47-65 years). Shoulder forward elevation, external rotation, and Constant-Murley and American Shoulder and Elbow Surgeons scores were assessed. Pain was assessed by a 0- to 10-point visual analog scale. Acromiohumeral distance and cuff tear arthropathy (staged according to the Hamada classification) were evaluated on radiographs. Shoulder forward elevation, external rotation, Constant-Murley scores, and American Shoulder and Elbow Surgeons scores improved at 6 months. However, although shoulder motion values and Constant-Murley scores remained unchanged between the 6-month and latest evaluations, American Shoulder and Elbow Surgeons scores decreased in this period (median, 71; range, 33-88 versus median, 68; range, 33-85; p = 0.009). Visual analog scale scores improved between the preoperative and 6-month evaluations but then worsened (representing worse pain) between the 6-month and latest evaluations (median, 2; range, 0-5 versus median, 2; range, 1-6; p = 0.034), but scores at latest followup were still lower than preoperative values (median, 7; range, 4-8; p = 0.003). Although acromiohumeral distance values were increased at 6 months (median, 8 mm; range, 6-10 mm; p = 0.023), the values at latest followup (median, 8 mm; range, 5-10 mm) were no different from the preoperative ones (mean, 7 mm; range, 6-9 mm; p > 0.05). According to Hamada classification, all patients were Grade 1 both pre- and postoperatively, except one who was Grade 3 at latest followup. The latissimus dorsi tendon transfer may improve shoulder function in irreparable massive rotator cuff tears. However, because the tenodesis effect loses its strength with time, progression of the arthropathy should be expected over time. Nevertheless, latissimus dorsi tendon transfer may help to delay the need for reverse shoulder arthroplasty for these patients. Level IV, therapeutic study. See Instructions for Authors for a complete description of levels of evidence.
Relationship of Tear Size and Location to Fatty Degeneration of the Rotator Cuff
Kim, H. Mike; Dahiya, Nirvikar; Teefey, Sharlene A.; Keener, Jay D.; Galatz, Leesa M.; Yamaguchi, Ken
2010-01-01
Background: Fatty degeneration of the rotator cuff muscles may have detrimental effects on both anatomical and functional outcomes following shoulder surgery. The purpose of this study was to investigate the relationship between tear geometry and muscle fatty degeneration in shoulders with a deficient rotator cuff. Methods: Ultrasonograms of both shoulders of 262 patients were reviewed to assess the type of rotator cuff tear and fatty degeneration in the supraspinatus and infraspinatus muscles. The 251 shoulders with a full-thickness tear underwent further evaluation for tear size and location. The relationship of tear size and location to fatty degeneration of the supraspinatus and infraspinatus muscles was investigated with use of statistical comparisons and regression models. Results: Fatty degeneration was found almost exclusively in shoulders with a full-thickness rotator cuff tear. Of the 251 shoulders with a full-thickness tear, eighty-seven (34.7%) had fatty degeneration in either the supraspinatus or infraspinatus, or both. Eighty-two (32.7%) of the 251 full-thickness tears had a distance of 0 mm between the biceps tendon and anterior margin of the tear. Ninety percent of the full-thickness tears with fatty degeneration in both muscles had a distance of 0 mm posterior from the biceps, whereas only 9% of those without fatty degeneration had a distance of 0 mm. Tears with fatty degeneration had significantly greater width and length than those without fatty degeneration (p < 0.0001). Tears with fatty degeneration had a significantly shorter distance posterior from the biceps than those without fatty degeneration (p < 0.0001). The distance posterior from the biceps was found to be the most important predictor for supraspinatus fatty degeneration, whereas tear width and length were found to be the most important predictors for infraspinatus fatty degeneration. Conclusions: Fatty degeneration of the rotator cuff muscles is closely associated with tear size and location. The finding of this study suggests that the integrity of the anterior supraspinatus tendon is important to the development of fatty degeneration. Patients with full-thickness tears that extend through this area may benefit from earlier surgical intervention if fatty degeneration has not already occurred. Additionally, the findings suggest the importance of secure fixation and healing of the anterior aspect of the supraspinatus with surgical repair. PMID:20360505
Radial tears associated with cleavage tears of the medial meniscus in athletes.
Kidron, Amos; Thein, Rafael
2002-03-01
To evaluate the significance of a small radial tear in the root of the posterior horn of the medial meniscus in an otherwise normal-looking meniscus in individuals who play vigorous sports. Retrospective review. Arthroscopy was performed in 1,270 patients; 11 patients (0.86%) had a small radial tear in the root of the medial meniscus. Trimming of the tear revealed a large horizontal cleavage tear of the posterior horn and body of the meniscus. The average age of the affected patients was 29.6 years (range, 21 to 45 years), and all were active in sports. Magnetic resonance imaging was of dubious diagnostic value. Three patients had undergone previous arthroscopy at which time the small radial root tear had been noted but was not thought to warrant treatment. All 11 patients returned to their former levels of activity after adequate surgery. When a radial root tear in the medial meniscus is found in an athletic patient, the edges of the tear should be trimmed, the root of the medial meniscus examined, and any additional torn cartilage resected.
Patterns of meniscal tears associated with anterior cruciate ligament lesions in athletes.
Binfield, P M; Maffulli, N; King, J B
1993-09-01
In this study, 400 clinically anterior cruciate ligament (ACL) deficient knees were arthroscoped and studied prospectively in the period January 1986 to April 1992. An ACL tear was always confirmed, and 41 per cent of these patients did not have an associated meniscal tear. In 30.25 per cent the lateral meniscus was torn; in 21.25 per cent the ACL tear was associated with a medial meniscus tear, and in the remaining 7 per cent both menisci were torn. The most frequently associated meniscal injury was the bucket handle tear of the medial meniscus (9 per cent), followed by the posterior horn tear of the lateral meniscus, which showed the same frequency as the ragged (or degenerated) tear of the lateral meniscus (6 per cent). The horizontal tear of the posterior part of the lateral meniscus showed a prevalence of 4.3 per cent. This picture is probably dependent on a secondary referral nature of the centre surveyed, in which the average time between injury and arthroscopy was 23.3 months.
Ocular Pharmacology of Tear Film, Dry Eye, and Allergic Conjunctivitis.
Gulati, Shilpa; Jain, Sandeep
2017-01-01
Dry Eye Disease (DED) is "a multifactorial disease of the tears and ocular surface that results in symptoms of discomfort, visual disturbance, and tear-film instability with potential damage to the ocular surface." DED comprises two etiologic categories: aqueous-deficient dry eye (ADDE) and evaporative dry eye (EDE). Diagnostic workup of DED should include clinical history, symptom questionnaire, fluorescein TBUT, ocular surface staining grading, Schirmer I/II, lid and meibomian pathology, meibomian expression, followed by other available tests. New diagnostic tests employ the Oculus Keratograph, which performs non-invasive tear-film analysis and a bulbar redness (BR). The TearLab Osmolarity Test enables rapid clinical evaluation of tear osmolarity. Lipiview is a recently developed diagnostic tool that uses interferometry to quantitatively evaluate tear-film thickness. In DED, epithelial and inflammatory cells produce a variety of inflammatory mediators. A stagnant tear film and decreased concentration of mucin result in the accumulation of inflammatory factors that can penetrate tight junctions and cause epithelial cell death. DED treatment algorithms are based on severity of clinical signs and symptoms, and disease etiology. Therapeutic approaches include lubricating artificial tears and immunomodulatory agents.
Zhang, Luyan; Sun, Xiyu; Yu, Ye; Xiong, Yan; Cui, Yuxin; Wang, Qinmei; Hu, Liang
2016-01-01
To investigate the correlations between corneal sensation, tear meniscus volume, and tear film osmolarity after femtosecond laser-assisted LASIK (FS-LASIK) surgery. In this prospective clinical study, 31 patients undergoing FS-LASIK for myopia were recruited. The upper and lower tear meniscus volumes (UTMV and LTMV) were measured by customized anterior segment optical coherence tomography, tear film osmolarity was measured by a TearLab Osmolarity test device, central corneal sensation was measured by a Cochet-Bonner esthesiometer preoperatively, at 1 week, 1 and 3 months postoperatively. Repeated measures analysis of variance was used to evaluate whether the tear film osmolarity, tear meniscus volume, and corneal sensation were changed after surgery. The correlations between these variables were analyzed by the Pearson correlation analysis. The tear film osmolarity was (310.03 ± 16.48) mOsms/L preoperatively, (323.51 ± 15.92) mOsms/L at 1 week, (319.93 ± 14.27) mOsms/L at 1 month, and (314.97±12.91) mOsms/L at 3 months. The UTMV was (0.42±0.15), (0.25± 0.09), (0.30±0.11), and (0.35±0.09) μL, respectively; the LTMV was (0.60±0.21),(0.37±0.08), (0.44± 0.14), and (0.52±0.17) μL, respectively. The tear film osmolarity was significantly higher at 1 week and 1 month postoperatively compared with the baseline (P=0.001, 0.004), and reduced to the preoperative level at 3 months (P=0.573). The UTMV, LTMV, and corneal sensation values presented significant decreases at all postoperative time points (all P<0.05). The Pearson correlation analysis showed the postoperative UTMV had a weak relationship with corneal sensation at 1 week after surgery (r=0.356,P=0.005). There were significant correlations between the preoperative LTMV and corneal sensation at 1 week, 1 and 3 months (respectively, r=0.422, 0.366, 0.352;P=0.001, 0.004, 0.006). No significant correlations were found between the tear film osmolarity, tear meniscus volume, and corneal sensation after surgery (all P>0.05). The tear film osmolarity, tear meniscus volume, and corneal sensation became aggravated due to the FS-LASIK surgery procedures. There were significant correlations between the preoperative tear meniscus volume and recovery of corneal sensation early after surgery. A higher tear meniscus volume before surgery may contribute to a faster corneal sensation recovery.
Status of the contralateral rotator cuff in patients undergoing rotator cuff repair.
Ro, Kyung-Han; Park, Jong-Hoon; Lee, Soon-Hyuck; Song, Dong-Ik; Jeong, Ha-Joon; Jeong, Woong-Kyo
2015-05-01
Although the prevalence of rotator cuff tear (RCT) in the general population has been analyzed, little information is available on the status of the opposite-side rotator cuff in patients who have undergone arthroscopic rotator cuff repair. To identify the characteristics of the contralateral shoulder and to identify factors associated with RCT of the contralateral shoulder in patients who underwent surgery for symptomatic RCT. The hypothesis was that the prevalence of RCT in the contralateral shoulder would be higher in patients with increasingly larger cuff tears requiring surgical intervention. Case series; Level of evidence, 4. The study cohort consisted of 140 patients with RCT who underwent arthroscopic rotator cuff repair. Opposite-shoulder rotator cuff tendons of all patients were evaluated by ultrasonography. Demographic information and factors related to contralateral RCT were investigated, and risk factors associated with contralateral RCT were assessed. Of the 140 patients who underwent arthroscopic rotator cuff repair, 54 (38.6%) had an RCT of the contralateral shoulder. Of 51 patients with partial-thickness and small-sized full-thickness tears of the operated shoulder, 35 (68.6%) had no tears; 14 (27.5%) had partial-thickness tears; and 2 (3.9%) had small-sized full-thickness tears of the contralateral shoulder. Of 75 patients with medium-sized full-thickness tears, 43 (57.3%) had no tears; 12 (16%) had partial-thickness tears; and 20 (26.7%) had full-thickness tears of the contralateral shoulder. Of 14 patients with large to massive full-thickness tears, 8 (57.1%) had no tears; 1 (7.1%) had a partial-thickness tear; and 5 (35.7%) had full-thickness tears of the contralateral shoulder. The prevalence of RCT of the contralateral shoulder differed significantly among groups classified by tear size (P=.007). The mean American Shoulder and Elbow Surgeons score was significantly lower in the RCT than in the nontear group (55.8±16.9 vs 61.6±13.3; P=.03). Of 29 subjects with symptomatic tears involving the nondominant arm, 17 (58.6%) had contralateral asymptomatic RCT, compared with 37 of 111 (33.3%) subjects with symptomatic tears involving the dominant arm (P=.007). The prevalence of RCT of the contralateral asymptomatic shoulder tends to be higher in patients with more symptomatic RCT on one side, in patients with medium-sized or larger RCT in the operated shoulder, and in patients with symptomatic RCT in the nondominant arm. © 2015 The Author(s).
Response of Metals and Metallic Structures to Dynamic Loading
1978-05-01
materials for service by testing under high rates of loading. Impact tests such as the Charpy test, the drop-weight tear test, and the dynamic tear...have clearly shown this for precracked charpy specimens and for the drop-weight tear test. Hence, there is a strong need for additional dynamic...dynamic fracture resistance ( Charpy , dynamic-tear, drop-weight tear test, etc.), normally assures that fracture in dynamically loaded structures is
Interferometer for measuring the dynamic surface topography of a human tear film
NASA Astrophysics Data System (ADS)
Primeau, Brian C.; Greivenkamp, John E.
2012-03-01
The anterior refracting surface of the eye is the thin tear film that forms on the surface of the cornea. Following a blink, the tear film quickly smoothes and starts to become irregular after 10 seconds. This irregularity can affect comfort and vision quality. An in vivo method of characterizing dynamic tear films has been designed based upon a near-infrared phase-shifting interferometer. This interferometer continuously measures light reflected from the tear film, allowing sub-micron analysis of the dynamic surface topography. Movies showing the tear film behavior can be generated along with quantitative metrics describing changes in the tear film surface. This tear film measurement allows analysis beyond capabilities of typical fluorescein visual inspection or corneal topography and provides better sensitivity and resolution than shearing interferometry methods. The interferometer design is capable of identifying features in the tear film much less than a micron in height with a spatial resolution of about ten microns over a 6 mm diameter. This paper presents the design of the tear film interferometer along with the considerations that must be taken when designing an interferometer for on-eye diagnostics. Discussions include eye movement, design of null optics for a range of ocular geometries, and laser emission limits for on-eye interferometry.
Yoon, Jin Sook; Choi, Soo Hyun; Lee, Joon H; Lee, Sung Jun; Lee, Sang Yeul
2010-02-01
To measure tear nerve growth factor (NGF) concentrations in cases of active thyroid-associated ophthalmopathy (TAO) before and after glucocorticoid treatment, and to correlate NGF levels with disease inflammatory activity and thyroid autoantibody concentration. The study involved 20 patients with active TAO and 20 age- and gender-matched controls. Tear break-up time (BUT) was obtained, the Schirmer test was performed, and tear NGF/total protein ratio was measured in control subjects and patients with active TAO before, and 2 and 4 weeks after, steroid treatment. Tear BUT and Schirmer values significantly increased after 2 and 4 weeks of steroid treatment (p < 0.001 and p = 0.004 respectively). Baseline tear NGF/total protein ratio was higher in patients with active TAO than in control subjects, and the ratio significantly decreased after 2 and 4 weeks of steroid treatment (p < 0.001). Tear NGF/total protein ratio did not correlate with inflammatory activity score, exophthalmos value and thyroid binding inhibiting immunoglobulin (TBII) level (p > 0.05). Tear NGF may have a specific role in ocular surface inflammation, which protects against ocular surface damage in patients with active TAO. Anti-inflammatory treatment significantly reduced the level of NGF in tears, increased tear film stability and production, and decreased congestive symptoms.
Choi, Eui-Sung; Park, Sang-Jun
2015-06-01
To investigate the incidence of root tears of the posterior horn of the medial meniscus in total knee replacement arthroplasty for knee osteoarthritis and retrospectively analyze clinical results and factors associated with root tears. There were 197 knees of 140 enrolled patients who had undergone total knee replacement arthroplasty between September 2010 and May 2014. The presence of a root tear of the posterior horn of the medial meniscus was confirmed in all patients. Statistical analysis was performed to investigate the correlation between root tears and the possible factors of meniscal tears including gender, age, severity of symptoms (visual analogue scale [VAS] score and medial joint line tenderness), grade of osteoarthritis (Kellgren-Lawrence grading scale), body mass index (BMI), varus deformity, and mechanical axis deviation. Meniscal tears were observed in 154 knees (78.17%). The root tear had correlation with the severity of osteoarthritis (p<0.05), varus deformity (p<0.05), mechanical axis deviation (p<0.05), and BMI (p<0.05). Factors considered to represent the severity of osteoarthritis were found to be associated with root tears of the medial meniscus posterior horn. Increased BMI seemed to be associated with the increased incidence of root tears of the medial meniscus posterior horn.
Wang, Linlin; Liu, Qi; Jing, Dongdong; Zhou, Shanyu; Shao, Longquan
2014-04-01
The aim of this study was to evaluate the effect of TiO2 nanoparticles on the mechanical and anti-ageing properties of a medical silicone elastomer and to assess the biocompatibility of this novel combination. TiO2 (P25, Degussa, Germany) nanoparticles were mixed with the silicone elastomer (MDX4-4210, Dow Corning, USA) at 2%, 4%, and 6% (w/w) using silicone fluid as diluent (Q7-9180, Dow Corning, USA). Blank silicone elastomer served as the control material. The physical properties and biocompatibility of the composites were examined. The tensile strength was tested for 0% and 6% (w/w) before and after artificial ageing. SEM analysis was performed. TiO2 nanoparticles improved the tensile strength and Shore A hardness of the silicone elastomer (P<0.05). However, a decrease in the elongation at break and tear strength was found for the 6% (w/w) composite (P<0.05). All the ageing methods had no effect on the tensile strength of the 6% (w/w) composite (P>0.05), but thermal ageing significantly decreased the tensile strength of the control group (P<0.05). Cellular viability assays indicated that the composite exhibited biocompatibility. We obtained a promising restorative material which yields favourable physical and anti-ageing properties and is biocompatible in our in vitro cellular studies. Copyright © 2014 Elsevier Ltd. All rights reserved.
Reduced tear production in three canine endocrinopathies.
Williams, D L; Pierce, V; Mellor, P; Heath, M F
2007-05-01
Previous reports have suggested that hypothyroid and diabetic patients can be predisposed to keratoconjunctivitis sicca. This study aimed to measure tear production in dogs with diabetes, hypothyroidism and hyperadrenocorticism using the Schirmer tear test and to compare these results with Schirmer tear test values for a group of normal dogs. Schirmer tear tests were performed on 16 dogs with hyperadrenocorticism, 18 with diabetes and 12 with hypothyroidism together with 100 control dogs. Corneal sensitivity was also measured in 12 of the 18 diabetic dogs with a Cochet Bonnet aesthesiometer and compared with age- and breed-matched normal dogs. Schirmer tear test values in dogs with hypothyroidism, hyperadrenocorticism and diabetes were 12.3+/-3.2, 14.0+/-4.0 and 12.3+/-5.3 mm/minutes, respectively. Schirmer tear test values were significantly lower than that for the control group (19.6+/-4.2 mm/minutes) in all dogs with an endocrinopathy. Only in two hypothyroid dogs and three diabetics, this was manifested as profound keratoconjunctivitis sicca with Schirmer tear test value lower than 5 mm/minutes. Diabetic dogs had significantly reduced corneal sensitivity compared with a matched set of control dogs. This study shows a significant reduction in tear production in animals with diabetes mellitus, hypothyroidism and hyperadrenocorticism. Further research is needed to elucidate the mechanisms by which this reduction in tear production occurs. Assessment of tear production should be undertaken in animals diagnosed with these endocrinopathies, as these animals may progress to clinical keratoconjunctivitis sicca.
Dry eye symptoms are increased in mice deficient in phospholipid transfer protein (PLTP).
Setälä, Niko L; Metso, Jari; Jauhiainen, Matti; Sajantila, Antti; Holopainen, Juha M
2011-05-01
In the tear fluid the outermost part facing the tear-air interface is composed of lipids preventing evaporation of the tears. Phospholipid transfer protein (PLTP) mediates phospholipid transfer processes between serum lipoproteins and is also a normal component of human tears. To study whether PLTP plays any functional role in tear fluid we investigated PLTP-deficient mice, applying functional and morphologic analyses under normal housing and experimentally induced dry eye conditions. Aqueous tear fluid production, corneal epithelial morphology, barrier function, and occludin expression were assessed. In mice with a full deficiency of functional PLTP enhanced corneal epithelial damage, increased corneal permeability to carboxyfluorescein, and decreased corneal epithelial occludin expression were shown. These pathologic signs were worsened by experimentally induced dry eye both in wild-type and PLTP knock-out mice. Deficiency in the production of tear PLTP in mice is accompanied by corneal epithelial damage, a feature that is typical in human dry eye syndrome (DES). To complement animal experiments we collected tear fluid from human dry eye patients as well as healthy control subjects. Increased tear fluid PLTP activity was observed among DES patients. In conclusion, the presence of PLTP in tear fluid appears to be essential for maintaining a healthy and functional ocular surface. Increased PLTP activity in human tear fluid in DES patients suggests an ocular surface protective role for this lipid transfer protein. Copyright © 2011 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.
Diadenosine tetraphosphate contributes to carbachol-induced tear secretion.
Fonseca, Begoña; Martínez-Águila, Alejandro; Díaz-Hernández, Miguel; Pintor, Jesús
2015-03-01
The purpose of this study is to investigate if the cholinergic stimulation by carbachol on tear secretion is a direct process or if it is also mediated by purinergic mechanisms. Experiments were performed in New Zealand male rabbits. The amount of tear secretion was measured with Schirmer's test and then analyzed by a HPLC protocol in order to study the nucleotide levels. Animal eyes were instilled with carbachol (a cholinergic agonist), pirenzepine, gallamine and 4-DAMP (muscarinic antagonists), PPADS, suramin and reactive blue 2 (purinergic antagonists), and a P2Y2 receptor small interfering RNA (siRNA). Tear secretion increased with the instillation of carbachol, approximately 84 % over control values 20 min after the instillation and so did Ap4A and ATP release. When we applied carbachol in the presence of muscarinic antagonists, tear volume only increased to 4 % with atropine, 12 % in the case of pirenzepine, 3 % with gallamine, and 8 % with 4-DAMP. In the presence of carbachol and purinergic antagonists, tear secretion was increased to 12 % (all values compared to basal tear secretion). By analyzing tear secretion induced with carbachol in presence of a P2Y2 receptor siRNA, we found that tear secretion was diminished to 60 %. The inhibition of tear secretion in the presence of carbachol and purinergic antagonists or P2Y2 siRNA occurred with no apparent change in the tear amount of Ap4A. These experiments demonstrated the participation of Ap4A in lacrimal secretion process.
Evaluation of cartilage degeneration in a rat model of rotator cuff tear arthropathy
Kramer, Erik J.; Bodendorfer, Blake M.; Laron, Dominique; Wong, Jason; Kim, Hubert T.; Liu, Xuhui; Feeley, Brian T.
2013-01-01
Introduction Rotator cuff tears are the most common injury seen by shoulder surgeons. Many late stage rotator cuff tear patients develop glenohumeral osteoarthritis as a result of torn cuff tendons, termed cuff tear arthropathy. However, the mechanisms of cuff tear arthropathy have not been fully established. It has been hypothesized that a combination of synovial and mechanical factors contribute equally to the development of cuff tear arthropathy. The goal of this study was to assess the utility of this model in investigating cuff-tear arthropathy. Methods We utilized a rat model which accurately reflects rotator cuff muscle degradation after massive rotator cuff tears through either infraspinatus and supraspinatus tenotomy or suprascapular nerve transection. Using a Modified-Mankin Scoring System (MMS), we found significant glenohumeral cartilage damage following both rotator cuff tenotomy and suprascapular nerve transection after only 12 weeks. Results Cartilage degeneration was similar between groups, and was present on both the humeral head and the glenoid. Denervation of the supraspinatus and infraspinatus muscles without opening the joint capsule caused cartilage degeneration similar to that found in the tendon transection group. Conclusions These results suggest that altered mechanical loading after rotator cuff tears is the primary factor in cartilage degeneration after rotator cuff tears. Clinically, understanding the process of cartilage degeneration after rotator cuff injury will help guide treatment decisions in the setting of rotator cuff tears. Level of evidence Basic Science Study, Animal Model PMID:23664745
A review of patient and skin characteristics associated with skin tears.
Rayner, R; Carville, K; Leslie, G; Roberts, P
2015-09-01
Skin tears are the most common wound among the elderly and have the potential to cause infection, form chronic wounds, reduce quality of life and increase health-care costs. Our aim was to identify studies that reviewed patient and skin characteristics associated with skin tears. A review of skin tear studies reported in the English literature between 1980 and 2013 was undertaken using the following electronic databases: PubMed, Medline, CINAHL, Embase, Scopus, Evidence Based and Medicine Reviews (EBM). Search terms included aged, skin, tears or lacerations, skin tearing, geri tear, epidermal tear and prevalence. There were 343 articles found with using the search terms. After abstract review nine were found to be relevant to the search. The principle findings from these eight published articles and one unpublished study revealed that the most common patient characteristics were a history of skin tears, impaired mobility and impaired cognition. Skin characteristics associated with skin tears included senile purpura, ecchymosis and oedema. This review provides an overview of identified patient and skin characteristics that predispose the elderly to skin tears and exposes the lack of research within this domain. R. Rayner is a recipient of a 2013 Australian Postgraduate Award, Curtin University Postgraduate Scholarship and a Wound Management Cooperative Research Centre (CRC) PhD stipend. The School of Nursing, Midwifery and Paramedicine, Curtin University and the Silver Chain Group, Western Australia are participants in the Wound Management Innovation CRC. No conflict of interest exists among the authors.
Empirical study of alginate impression materials by customized proportioning system
2016-01-01
PURPOSE Alginate mixers available in the market do not have the automatic proportioning unit. In this study, an automatic proportioning unit for the alginate mixer and controller software were designed and produced for a new automatic proportioning unit. With this device, it was ensured that proportioning operation could arrange weight-based alginate impression materials. MATERIALS AND METHODS The variation of coefficient in the tested groups was compared with the manual proportioning. Compression tension and tear tests were conducted to determine the mechanical properties of alginate impression materials. The experimental data were statistically analyzed using one way ANOVA and Tukey test at the 0.05 level of significance. RESULTS No statistically significant differences in modulus of elastisity (P>0.3), tensional/compresional strength (P>0.3), resilience (P>0.2), strain in failure (P>0.4), and tear energy (P>0.7) of alginate impression materials were seen. However, a decrease in the standard deviation of tested groups was observed when the customized machine was used. To verify the efficiency of the system, powder and powder/water mixing were weighed and significant decrease was observed. CONCLUSION It was possible to obtain more mechanically stable alginate impression materials by using the custom-made proportioning unit. PMID:27826387
Inhibition of PDGFR signaling prevents muscular fatty infiltration after rotator cuff tear in mice.
Shirasawa, Hideyuki; Matsumura, Noboru; Shimoda, Masayuki; Oki, Satoshi; Yoda, Masaki; Tohmonda, Takahide; Kanai, Yae; Matsumoto, Morio; Nakamura, Masaya; Horiuchi, Keisuke
2017-01-31
Fatty infiltration in muscle is often observed in patients with sizable rotator cuff tear (RCT) and is thought to be an irreversible event that significantly compromises muscle plasticity and contraction strength. These changes in the mechanical properties of the affected muscle render surgical repair of RCT highly formidable. Therefore, it is important to learn more about the pathology of fatty infiltration to prevent this undesired condition. In the present study, we aimed to generate a mouse model that can reliably recapitulate some of the important characteristics of muscular fatty infiltration after RCT in humans. We found that fatty infiltration can be efficiently induced by a combination of the following procedures: denervation of the suprascapular nerve, transection of the rotator cuff tendon, and resection of the humeral head. Using this model, we found that platelet-derived growth factor receptor-α (PDGFRα)-positive mesenchymal stem cells are induced after this intervention and that inhibition of PDGFR signaling by imatinib treatment can significantly suppress fatty infiltration. Taken together, the present study presents a reliable fatty infiltration mouse model and suggests a key role for PDGFRα-positive mesenchymal stem cells in the process of fatty infiltration after RCT in humans.
Inhibition of PDGFR signaling prevents muscular fatty infiltration after rotator cuff tear in mice
Shirasawa, Hideyuki; Matsumura, Noboru; Shimoda, Masayuki; Oki, Satoshi; Yoda, Masaki; Tohmonda, Takahide; Kanai, Yae; Matsumoto, Morio; Nakamura, Masaya; Horiuchi, Keisuke
2017-01-01
Fatty infiltration in muscle is often observed in patients with sizable rotator cuff tear (RCT) and is thought to be an irreversible event that significantly compromises muscle plasticity and contraction strength. These changes in the mechanical properties of the affected muscle render surgical repair of RCT highly formidable. Therefore, it is important to learn more about the pathology of fatty infiltration to prevent this undesired condition. In the present study, we aimed to generate a mouse model that can reliably recapitulate some of the important characteristics of muscular fatty infiltration after RCT in humans. We found that fatty infiltration can be efficiently induced by a combination of the following procedures: denervation of the suprascapular nerve, transection of the rotator cuff tendon, and resection of the humeral head. Using this model, we found that platelet-derived growth factor receptor-α (PDGFRα)-positive mesenchymal stem cells are induced after this intervention and that inhibition of PDGFR signaling by imatinib treatment can significantly suppress fatty infiltration. Taken together, the present study presents a reliable fatty infiltration mouse model and suggests a key role for PDGFRα-positive mesenchymal stem cells in the process of fatty infiltration after RCT in humans. PMID:28139720
Effects of polar solvents on the mechanical behavior of fish scales.
Murcia, Sandra; Li, Guihua; Yahyazadehfar, Mobin; Sasser, Mikaela; Ossa, Alex; Arola, D
2016-04-01
Fish scales are unique structural materials that serve as a form of natural armor. In this investigation the mechanical behavior of scales from the Cyprinus carpio was evaluated after exposure to a polar solvent. Uniaxial tensile and tear tests were conducted on specimens prepared from the scales of multiple fish extracted from near the head, middle and tail regions, and after exposure to ethanol for periods from 0 to 24h. Submersion in ethanol caused instantaneous changes in the tensile properties regardless of anatomical site, with increases in the elastic modulus, strength and modulus of toughness exceeding 100%. The largest increase in properties overall occurred in the elastic modulus of scales from the tail region and exceeded 200%. Although ethanol treatment had significant effect on the tensile properties, it had limited influence on the tear resistance. The contribution of ethanol to the mechanical behavior appears to be derived from an increase in the degree of interpeptide hydrogen-bonding of the collagen molecules. Spatial variations in the effects of ethanol exposure on the mechanical behavior arise from the differences in degree of mineralization and lower mineral content in scales of the tail region. Copyright © 2015 Elsevier B.V. All rights reserved.
Wang, Ying; Johnson, John A.; Spinale, Francis G.; Sutton, Michael A.; Lessner, Susan M.
2014-01-01
The left anterior descending (LAD) coronary artery is the most frequently involved vessel in coronary artery dissection, a cause of acute coronary syndrome or sudden cardiac death. The biomechanical mechanisms underlying arterial dissection are not well understood. This study investigated the dissection properties of LAD specimens harvested from explanted hearts at the time of cardiac transplantation, from patients with primary dilated cardiomyopathy (n=12). Using a previously validated approach uniquely modified for these human LAD specimens, we quantified the local energy release rate, G, within different arterial layers during experimental dissection events (tissue tearing). Results show that the mean values of G during arterial dissection within the intima and within the media in human LADs are 20.7±16.5 J/m2 and 10.3±5.0 J/m2, respectively. The difference in dissection resistance between tearing events occurring within the intima and within the media is statistically significant. Our data fall in the same order of magnitude as most previous measurements of adhesive strength in other human arteries, with the differences in measured values of G within the layers most likely due to histologically observed differences in the structure and composition of arterial layers. PMID:24729631
Yoon, Young Chun; Lee, Doo-Hyung; Lee, Michael Young; Yoon, Seung-Hyun
2017-05-01
To determine the efficacy of polydeoxyribonucleotide (PDRN) injection for rotator cuff disease (RCD). Case-controlled, retrospective, comparative study. Outpatient clinic at a university-affiliated tertiary care hospital. Patients (N=106) with chronic nontraumatic refractory RCD who were unresponsive to at least 1 month of conservative treatment: 55 patients received PDRN injection (PDRN group) and 51 continued conservative treatment (control group). Not applicable. Shoulder Pain and Disability Index, score on a visual analog scale of the average shoulder pain level, number of analgesic ingestions per day, isometric strength of shoulder abductor, active range of motion (flexion, abduction, internal rotation, external rotation), and maximal tear size of tendon on ultrasonography at pretreatment and 3 and 6 months postinjection. There was no significant difference between the 2 groups in terms of age, sex, shoulder affected, duration of symptoms, and ultrasonographic findings at pretreatment. Compared with the control group, the treatment group showed a significant improvement in Shoulder Pain and Disability Index, visual analog scale score, and number of analgesic ingestions per day. However, there was no difference in isometric strength, active range of motion, and maximal tear size of tendon. No adverse events were reported. To our knowledge, this is the first study to assess the efficacy of PDRN injection for patients with RCD. The PDRN injection group showed improvement in pain and subjective disability in patients with RCD and continued to show improvement for 3 months thereafter; the PDRN injection can be an optional treatment for patients with chronic RCD who show no response to other treatments. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Arthroscopic biceps tenodesis: a new technique using bioabsorbable interference screw fixation.
Boileau, Pascal; Krishnan, Sumant G; Coste, Jean-Sebastien; Walch, Gilles
2002-01-01
To report a new technique of arthroscopic biceps tenodesis using bioabsorbable interference screw fixation and the early results. Prospective, nonrandomized study. The principle of arthroscopic biceps tenodesis is simple: after biceps tenotomy, the tendon is exteriorized and doubled on a suture; the biceps tendon is then pulled into a humeral socket (7 or 8 mm x 25 mm) drilled at the top of the bicipital groove, and fixed using a bioabsorbable interference screw (8 or 9 mm x 25 mm) under arthroscopic control. 43 patients treated with this technique between 1997 and 1999 were followed-up for at least 1 year. The technique was indicated in 3 clinical situations: (1) with arthroscopic cuff repair (3 cases), (2) in case of isolated pathology of the biceps tendon with an intact cuff (6 cases), and (3) as an alternative to biceps tenotomy in patients with massive, degenerative and irreparable cuff tears (34 cases). The biceps pathology was tenosynovitis (4 cases), prerupture (15 cases), subluxation (11 cases), and luxation (13 cases). The absolute Constant score improved from 43 points preoperatively to 79 points at review (P <.005). There was no loss of elbow movement and biceps strength was 90% of the strength of the other side. Two patients, operated on early in the series, presented with a rupture of the tenodesis. In both cases the bicipital tendon was very friable and the diameter of the screw proved to be insufficient (7 mm). No neurologic or vascular complications occurred. Arthroscopic biceps tenodesis using bioabsorbable screw fixation is technically possible and gives good clinical results. This technique can be used in cases of isolated pathologic biceps tendon or a cuff tear. A very thin, fragile, almost ruptured biceps tendon is the technical limit of this arthroscopic technique.
Wang, Allan; McCann, Philip; Colliver, Jess; Koh, Eamon; Ackland, Timothy; Joss, Brendan; Zheng, Minghao; Breidahl, Bill
2015-06-01
Tendon-bone healing after rotator cuff repair directly correlates with a successful outcome. Biological therapies that elevate local growth-factor concentrations may potentiate healing after surgery. To ascertain whether postoperative and repeated application of platelet-rich plasma (PRP) to the tendon repair site improves early tendon healing and enhances early functional recovery after double-row arthroscopic supraspinatus repair. Randomized controlled trial; Level of evidence, 1. A total of 60 patients underwent arthroscopic double-row supraspinatus tendon repair. After randomization, half the patients received 2 ultrasound-guided injections of PRP to the repair site at postoperative days 7 and 14. Early structural healing was assessed with MRI at 16 weeks, and cuff appearances were graded according to the Sugaya classification. Functional scores were recorded with the Oxford Shoulder Score; Quick Disability of the Arm, Shoulder and Hand; visual analog scale for pain; and Short Form-12 quality-of-life score both preoperatively and at postoperative weeks 6, 12, and 16; isokinetic strength and active range of motion were measured at 16 weeks. PRP treatment did not improve early functional recovery, range of motion, or strength or influence pain scores at any time point after arthroscopic supraspinatus repair. There was no difference in structural integrity of the supraspinatus repair on MRI between the PRP group (0% full-thickness retear; 23% partial tear; 77% intact) and the control group (7% full-thickness retear; 23% partial tear; 70% intact) at 16 weeks postoperatively (P = .35). After arthroscopic supraspinatus tendon repair, image-guided PRP treatment on 2 occasions does not improve early tendon-bone healing or functional recovery. © 2015 The Author(s).
Outcomes assessment in rotator cuff pathology: what are we measuring?
Makhni, Eric C; Steinhaus, Michael E; Morrow, Zachary S; Jobin, Charles M; Verma, Nikhil N; Cole, Brian J; Bach, Bernard R
2015-12-01
Assessments used to measure outcomes associated with rotator cuff pathology and after repair are varied. This lack of standardization leads to difficulty drawing comparisons across studies. We hypothesize that this variability in patient-reported outcome measures and objective metrics used in rotator cuff studies persists even in high-impact, peer reviewed journals. All studies assessing rotator cuff tear and repair outcomes in 6 orthopedic journals with a high impact factor from January 2010 to December 2014 were reviewed. Cadaveric and animal studies and those without outcomes were excluded. Outcome measures included range of motion (forward elevation, abduction, external rotation, and internal rotation), strength (in the same 4 planes), tendon integrity imaging, patient satisfaction, and functional assessment scores. Of the 156 included studies, 63% documented range of motion measurements, with 18% reporting range of motion in all 4 planes. Only 38% of studies reported quantitative strength measurements. In 65% of studies, tendon integrity was documented with imaging (38% magnetic resonance imaging/magnetic resonance anrhrogram, 31% ultrasound, and 8% computed tomography arthrogram). Finally, functional score reporting varied significantly, with the 5 most frequently reported scores ranging from 16% to 61% in studies, and 15 of the least reported outcomes were each reported in ≤6% of studies. Significant variability exists in outcomes reporting after rotator cuff tear and repair, making comparisons between clinical studies difficult. Creating a uniformly accepted, validated outcomes tool that assesses pain, function, patient satisfaction, and anatomic integrity would enable consistent outcomes assessment after operative and nonoperative management and allow comparisons across the literature. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Clinical outcomes of arthroscopic single and double row repair in full thickness rotator cuff tears.
Ji, Jong-Hun; Shafi, Mohamed; Kim, Weon-Yoo; Kim, Young-Yul
2010-07-01
There has been a recent interest in the double row repair method for arthroscopic rotator cuff repair following favourable biomechanical results reported by some studies. The purpose of this study was to compare the clinical results of arthroscopic single row and double row repair methods in the full-thickness rotator cuff tears. 22 patients of arthroscopic single row repair (group I) and 25 patients who underwent double row repair (group II) from March 2003 to March 2005 were retrospectively evaluated and compared for the clinical outcomes. The mean age was 58 years and 56 years respectively for group I and II. The average follow-up in the two groups was 24 months. The evaluation was done by using the University of California Los Angeles (UCLA) rating scale and the shoulder index of the American Shoulder and Elbow Surgeons (ASES). In Group I, the mean ASES score increased from 30.48 to 87.40 and the mean ASES score increased from 32.00 to 91.45 in the Group II. The mean UCLA score increased from the preoperative 12.23 to 30.82 in Group I and from 12.20 to 32.40 in Group II. Each method has shown no statistical clinical differences between two methods, but based on the sub scores of UCLA score, the double row repair method yields better results for the strength, and it gives more satisfaction to the patients than the single row repair method. Comparing the two methods, double row repair group showed better clinical results in recovering strength and gave more satisfaction to the patients but no statistical clinical difference was found between 2 methods.
Clinical outcomes of arthroscopic single and double row repair in full thickness rotator cuff tears
Ji, Jong-Hun; Shafi, Mohamed; Kim, Weon-Yoo; Kim, Young-Yul
2010-01-01
Background: There has been a recent interest in the double row repair method for arthroscopic rotator cuff repair following favourable biomechanical results reported by some studies. The purpose of this study was to compare the clinical results of arthroscopic single row and double row repair methods in the full-thickness rotator cuff tears. Materials and Methods: 22 patients of arthroscopic single row repair (group I) and 25 patients who underwent double row repair (group II) from March 2003 to March 2005 were retrospectively evaluated and compared for the clinical outcomes. The mean age was 58 years and 56 years respectively for group I and II. The average follow-up in the two groups was 24 months. The evaluation was done by using the University of California Los Angeles (UCLA) rating scale and the shoulder index of the American Shoulder and Elbow Surgeons (ASES). Results: In Group I, the mean ASES score increased from 30.48 to 87.40 and the mean ASES score increased from 32.00 to 91.45 in the Group II. The mean UCLA score increased from the preoperative 12.23 to 30.82 in Group I and from 12.20 to 32.40 in Group II. Each method has shown no statistical clinical differences between two methods, but based on the sub scores of UCLA score, the double row repair method yields better results for the strength, and it gives more satisfaction to the patients than the single row repair method. Conclusions: Comparing the two methods, double row repair group showed better clinical results in recovering strength and gave more satisfaction to the patients but no statistical clinical difference was found between 2 methods. PMID:20697485
Neurostimulation of the Lacrimal Nerve for Enhanced Tear Production
Kossler, Andrea L.; Wang, Jianhua; Feuer, William; Tse, David T.
2014-01-01
Purpose To design a proof-of-concept study to assess the effect of lacrimal nerve stimulation (LNS) with an implantable pulse generator (IPG) to increase aqueous tear production. Methods Experimental animal study design of six Dutch Belted rabbits. Ultra high-resolution optical coherence tomography (UHR-OCT) quantified tear production by measuring the baseline tear volume of each rabbit’s right and left eye. A neurostimulator was implanted adjacent to the right lacrimal nerve. After two minutes of LNS (100 μs, 1.6 mAmp, 20 Hz, 5–8 volts), the tear volumes were measured with UHR-OCT. The change in tear volume was quantified and compared to the non-stimulated left eye. Three rabbits underwent chronic LNS (100 μS, 1.6 mAmp, 10 Hz, 2 volts) and their lacrimal glands were harvested for histopathologic analysis. Results UHR-OCT imaging of the right eyes tear volume showed a 441% average increase in tear production after LNS as a percent of baseline. After stimulation, right eyes had statistically significant greater increase in tear volumes than left eyes (p=0.028, Wilcoxon test). Post-stimulation right eye tear volumes were significantly greater compared to baseline (p=0.028, Wilcoxon test). Histopathologic examination of the lacrimal glands showed no discernible tissue damage from chronic neurostimulation. Additionally, there were no gross adverse effects on the general well-beings of the animals due to chronic stimulation. Conclusions Lacrimal nerve stimulation with an implantable pulse generator appears to increase aqueous tear production. Chronic LNS showed no histopathologic lacrimal gland damage. This study suggests LNS is a promising new treatment strategy to increase aqueous tear production. PMID:25126767
Ham, Bryan M.; Cole, Richard B.; Jacob, Jean T.
2008-01-01
Purpose To identify and compare the phosphorylated lipids in normal and dry eye rabbit tears using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). Methods MALDI-TOF MS studies were performed on tear samples from normal and dry eyes of female New Zealand White rabbits. Experimental dry eye was induced by complete removal of the main and accessory lacrimal glands and nictitating membranes. A solid ionic crystal MALDI matrix of paranitroaniline and butyric acid was used to enhance the mass spectral responses of the phospholipids. In addition, a novel lipid isolation, preconcentration, and clean-up method using pipettes containing immobilized metal ion affinity chromatography (IMAC) medium was used. Results The polar phospholipids present in the normal and dry eye rabbit tears showed both similarities and differences. Species related to platelet-activating factor (PAF) and/or lysophosphatidylcholine (lyso-PC), phosphatidylcholine (PC), and sphingomyelin (SM) were found in both the normal and dry eye rabbit tears. However, the number of types and the concentrations of SM molecules were markedly greater in the dry eye tears than in the normal tears. In addition, phosphatidylserine (PS) species that were readily detectable in dry eye tears were not found in normal tears. Conclusions The combination of immobilized metal ion affinity chromatography and the solid ionic crystal matrix for MALDI enabled the detection and study of phosphorylated lipids in the tears. Specific differences between phospholipid levels in normal and dry eye tears were observable with this methodology. The appearance of various SM species only in the dry eye tears may provide markers for this disease state in the future. PMID:16877399
Fluorophotometric measurement of the buffering action of human tears in vivo.
Yamada, M; Kawai, M; Mochizuki, H; Hata, Y; Mashima, Y
1998-10-01
The buffering action of human tears is thought to be important to keep its pH constant. We measured the change in pH in the precorneal tear film in vivo when the acidic solution is challenged, using a fluorophotometric technique. Twelve eyes from 6 healthy subjects were entered in this study. Each subject was pretreated with either one drop of 0.4% oxybuprocaine for once (light anesthesia), three times (deep anesthesia), or none (controls). The measurement was initiated by instilling 20 microl of 0.067 M phosphate buffer at pH 5.5 containing 2 mM bis-carboxyethyl-carboxyfluorescein free acid, a pH sensitive dye, into the subject's eye. The pH was determined by the ratio of fluorescent intensities at two excitation wavelengths (490 and 430 nm). pH recovery time (PHRT) as defined by the time required for pH to reach 95% of pH at equilibrium was used for the marker of tear buffering action. Tear turnover rate was also determined using the fluorescent decay curve at 430 nm, which was independent of pH, but dependent on dye concentration. Immediately after the instillation, the pH value in the tear film was around 6.0-6.5 in all cases. The tear film rapidly became more alkaline, reaching its normal value in 2.3 +/- 0.5 min in untreated eyes. The pretreatment with 0.4% oxybuprocaine retarded the neutralization process. A single regression analysis revealed that the PHRT had a significant negative correlation with the tear turnover rate (r = -0.78). Our results suggest that the neutralization process of tears largely depends on the tear turnover rate. The buffering action of tears in vivo consists of the tear turnover as well as its chemical buffering capacity.
Pahwa, Shivani; Srivastava, Deep N; Sharma, Raju; Gamanagatti, Shivanand; Kotwal, Prakash P; Sharma, Vijay
2014-01-01
Aims: To compare conventional magnetic resonance imaging (MRI) and direct magnetic resonance (MR) arthrography in the evaluation of triangular fibrocartilage complex (TFCC) and intrinsic wrist ligament tears. Materials and Methods: T1-weighted, fat suppressed (FS) proton density plus T2-weighted (FS PD/T2), 3D multiple-echo data image combination (MEDIC) sequences and direct MR arthrography were performed in 53 patients with wrist pain. Images were evaluated for the presence and location of TFCC, scapholunate ligament (SLL) and lunatotriquetral ligament (LTL) tears, and imaging findings were compared with operative findings in 16 patients who underwent arthroscopy or open surgery (gold standard). Results: Sixteen patients underwent arthroscopy/open surgery: 12 TFCC tears were detected arthroscopically out of which 9 were detected on FS PD/T2 sequence, 10 on MEDIC sequence, and all 12 were detected on MR arthrography. The sensitivities of FS PD/T2, MEDIC sequences, and MR arthrography in the detection of TFCC tears were 75%, 83.3%, and 100%, respectively. Out of the eight arthroscopically confirmed SLL tears, three tears were detected on FS PD/T2 sequence, five on MEDIC sequence, and all eight were visualized on MR arthrography. The sensitivities of FS PD/T2, MEDIC sequences, and MR arthrography in detecting SLL tears were 37.5%, 62.5%, and 100%, respectively. One arthroscopically confirmed LTL tear was diagnosed on FS PD/T2 sequence, three on MEDIC sequence, and all five arthroscopically confirmed LTL tears were detected with MR arthrography. The sensitivities of PD, MEDIC sequences, and MR arthrography in detecting LTL tears were 20%, 40%, and 100%, respectively. Conclusions: MR arthrography is the most sensitive and specific imaging modality for the evaluation of wrist ligament tears. PMID:25114389
Forkel, Philipp; Reuter, Sven; Sprenker, Frederike; Achtnich, Andrea; Herbst, Elmar; Imhoff, Andreas; Petersen, Wolf
2015-01-01
Posterior lateral meniscus root tears (PLMRTs) affect the intra-articular pressure distribution in the lateral compartment of the knee. The biomechanical consequences of these injuries are significantly influenced by the integrity of the meniscofemoral ligaments (MFLs). A newly introduced arthroscopic classification system for PLMRTs that takes MFL integrity into account has not yet been clinically applied but may be useful in selecting the optimal method of PLMRT repair. Prospective ACL reconstruction data were collected. Concomitant injuries of the lateral meniscus posterior horn were classified according to their shape and MFL status. The classifications were: type 1, avulsion of the root; type 2, radial tear of the lateral meniscus posterior horn close to the root with an intact MFL; and type 3, complete detachment of the posterior meniscus horn. Between January 2011 and May 2012, 228 consecutive ACL reconstructions were included. Lateral and medial meniscus tears were identified in 38.2% (n = 87) and 44.7% (n = 102), respectively. Of the 87 lateral meniscus tears, 32 cases had PLMRTs; the overall prevalence of PLMRTs was 14% (n = 32). Two medial meniscus root tears were detected. All PLMRTs were classified according to the classification system described above, and the fixation procedure was adapted to the type of meniscus tear. The PLMRT tear is a common injury among patients undergoing ACL repair and can be arthroscopically classified into three different types. Medial meniscus root tears are rare in association with ACL tears. The PLMRT classification presented here may help to estimate the injury's impact on the lateral compartment and to identify the optimal treatment. These tears should not be overlooked, and the treatment strategy should be chosen with respect to the type of root tear. IV.
The effect of a rotator cuff tear and its size on three-dimensional shoulder motion.
Kolk, Arjen; Henseler, Jan Ferdinand; de Witte, Pieter Bas; van Zwet, Erik W; van der Zwaal, Peer; Visser, Cornelis P J; Nagels, Jochem; Nelissen, Rob G H H; de Groot, Jurriaan H
2017-06-01
Rotator cuff-disease is associated with changes in kinematics, but the effect of a rotator cuff-tear and its size on shoulder kinematics is still unknown in-vivo. In this cross-sectional study, glenohumeral and scapulothoracic kinematics of the affected shoulder were evaluated using electromagnetic motion analysis in 109 patients with 1) subacromial pain syndrome (n=34), 2) an isolated supraspinatus tear (n=21), and 3) a massive rotator cuff tear involving the supraspinatus and infraspinatus (n=54). Mixed models were applied for the comparisons of shoulder kinematics between the three groups during abduction and forward flexion. In the massive rotator cuff-tear group, we found reduced glenohumeral elevation compared to the subacromial pain syndrome (16°, 95% CI [10.5, 21.2], p<0.001) and the isolated supraspinatus tear group (10°, 95% CI [4.0, 16.7], p=0.002) at 110° abduction. Reduced glenohumeral elevation in massive rotator cuff tears coincides with an increase in scapulothoracic lateral rotation compared to subacromial pain syndrome (11°, 95% CI [6.5, 15.2], p<0.001) and supraspinatus tears (7°, 95% CI [1.8, 12.1], p=0.012). Comparable differences were observed for forward flexion. No differences in glenohumeral elevation were found between the subacromial pain syndrome and isolated supraspinatus tear group during arm elevation. The massive posterosuperior rotator cuff-tear group had substantially less glenohumeral elevation and more scapulothoracic lateral rotation compared to the other groups. These observations suggest that the infraspinatus is essential to preserve glenohumeral elevation in the presence of a supraspinatus tear. Shoulder kinematics are associated with rotator cuff-tear size and may have diagnostic potential. Copyright © 2017 Elsevier Ltd. All rights reserved.
Radiographic progression of arthritic changes in shoulders with degenerative rotator cuff tears.
Chalmers, Peter N; Salazar, Dane H; Steger-May, Karen; Chamberlain, Aaron M; Stobbs-Cucchi, Georgia; Yamaguchi, Ken; Keener, Jay D
2016-11-01
Very little longitudinal information has been available regarding the relationship of cuff tears and arthritis. The purpose of this study was to determine the midterm risk of and risk factors for rotator cuff tear arthropathy progression in a cohort of subjects with an asymptomatic rotator cuff tear. Baseline (visit 1), 5-year (visit 2), and most recent follow-up (visit 3) radiographs were reviewed in a cohort of 105 subjects enrolled for longitudinal surveillance of asymptomatic degenerative rotator cuff tears and 33 controls. The radiographs were assessed in a blinded, randomized fashion by 3 observers who graded glenohumeral arthritic changes using the Hamada scores, Samilson-Prieto (SPO) scores, and acromiohumeral interval (AHI). Osteoarthritis (SPO classification), cuff tear arthropathy (Hamada classification), and AHI progressed between visits 1 and 3 (median, 8 years; P < .001 in all cases). SPO progression was not significantly different for partial- vs. full-thickness vs. control baseline tear types (P = .19). Both full-thickness and partial-thickness tears had greater progression in Hamada scores than controls did in the first 5 years of follow-up (P = .02 and P = .03, respectively), but scores did not differ between partial- and full-thickness tears. Tears with and without enlargement did not differ in progression in SPO grade, Hamada grade, or AHI. Glenohumeral arthritic changes progress significantly but remain minimal within an 8-year period in early to moderate degenerative cuff disease. Whereas the presence of a rotator cuff tear influences progression in Hamada grade, the magnitude of radiographic progression is not influenced by tear severity or enlargement at midterm time points. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
van der List, Jelle P; DiFelice, Gregory S
2017-10-01
The general opinion is that outcomes of open primary repair of the anterior cruciate ligament (ACL) in the historical literature were disappointing. Since good outcomes of primary repair of proximal tears have recently been reported, we aimed to assess the role of tear location on open primary repair outcomes in the historical literature. All studies reporting outcomes of open primary ACL repair published between the inception of PubMed, Embase and Cochrane and 2000 were identified. Studies were included if tear location was reported. Outcome scores, return to sports, stability examinations, failures and patient satisfaction were collected and reviewed in the total study cohort and in a subgroup of studies treating only proximal tears. Spearman correlation analysis was performed between the percentage of proximal tears in the studies and all outcomes. Twenty-nine studies were included reporting outcomes of open primary in 1457 patients of which 72% had proximal and 23% midsubstance tears. Mean age was 30years, 65% were males, and mean follow-up was 3.6years. Good outcomes were noted in the total cohort, and excellent outcomes were noted following repair of proximal tears. Positive correlation was found between the percentage proximal tears in the studies and percentage satisfied patients (p=0.010). Tear location seems to have played a role on the outcomes of open primary ACL repair. Outcomes of open primary repair in patients with proximal tears were excellent, which confirms there may be a potential role for primary repair as treatment for proximal ACL tears. Copyright © 2017 Elsevier B.V. All rights reserved.
Learning curve of office-based ultrasonography for rotator cuff tendons tears.
Ok, Ji-Hoon; Kim, Yang-Soo; Kim, Jung-Man; Yoo, Tae-Wook
2013-07-01
To compare the accuracy of ultrasonography and MR arthrography (MRA) imaging in detecting of rotator cuff tears with arthroscopic finding used as the reference standard. The ultrasonography and MRA findings of 51 shoulders that underwent the arthroscopic surgery were prospectively analysed. Two orthopaedic doctors independently performed ultrasonography and interpreted the findings at the office. The tear size measured at ultrasonography and MRA was compared with the size measured at surgery using Pearson correlation coefficients (r). The sensitivity, specificity, accuracy, positive predictive value, negative predictive value and false-positive rate were calculated for a diagnosis of partial-and full-thickness rotator cuff tears. The kappa coefficient was calculated to verify the inter-observer agreement. The sensitivity of ultrasonography and MRA for detecting partial-thickness tears was 45.5 and 72.7 %, and that for full-thickness tears was 80.0 and 100 %, respectively. The accuracy of ultrasonograpy and MRA for detecting partial-thickness tears was 45.1 and 88.2 %, and that for full-thickness tears was 82.4 and 98 %, respectively. Tear size measured based on ultrasonography examination showed a poor correlation with the size measured at arthroscopic surgery (r = 0.21; p < 0.05). However, tear size estimated by MRA showed a strong correlation (r = 0.75; p < 0.05). The kappa coefficient was 0.47 between the two independent examiners. The accuracy of office-based ultrasonography for beginner orthopaedic surgeons to detect full-thickness rotator cuff tears was comparable to that of MRA but was less accurate for detecting partial-thickness tears and torn size measurement. Inter-observer agreement on the interpretation was fair. These results highlight the importance of the correct technique and experience in operation of ultrasonography in shoulder joint. Diagnostic study, Level II.
Effects of DA-6034 on aqueous tear fluid secretion and conjunctival goblet cell proliferation.
Choi, Seul Min; Lee, Yeong Geon; Seo, Mi Jung; Kang, Kyung Koo; Ahn, Byoung Ok; Yoo, Moohi
2009-06-01
This study was conducted to evaluate the effect of DA-6034, a potent secretagogue, on aqueous tear fluid secretion and its quality in normal rabbit. We also evaluated, in animal models of experimentally induced dry eye disease, its effectiveness over time to stimulate aqueous tear production by ocular ferning test and goblet cell proliferation. Aqueous tear production, total protein levels, and glycoprotein levels in normal rabbits were evaluated after topical application of DA-6034 (0.3, 1, and 3%). Moreover, time course aqueous tear volume measurement and ocular ferning test in tear fluid were performed in dry eyes of rabbits that had been given 1% atropine sulfate, topically. Altogether, tear fluid production and conjunctival goblet cell numbers were measured in dry eyes of mice that had been given topical scopolamine. Topical application of DA-6034 (0.3, 1, and 3%) significantly increased (P < 0.05) aqueous tear production in a concentration-dependent manner in normal rabbits. There was no change in total protein levels while glycoprotein levels were significantly increased (P < 0.05) at 3% DA-6034. The increase in aqueous tear fluid was significant (P < 0.05) and lasted for 2 h post-instillation in dry eyes of rabbits that had been given 1% atropine sulfate; 10-day repeated instillation of the drug in this model resulted in large and homogeneous fern-like tear patterns. In a mouse model, DA-6034 given as a 3% eyedrop solution significantly increased (P < 0.05) tear fluid production and conjunctival goblet cell number. These results suggest that DA-6034 accelerates not only tear secretion but also mucin production and may be a potential therapeutic agent for the treatment of dry eye disease.
Park, Gi-Young; Kwon, Dong Rak; Lee, Sang Chul
2015-11-01
Rotator cuff tendon tear is one of the most common causes of chronic shoulder pain and disability. In this study, we investigated the therapeutic effects of ultrasound-guided human umbilical cord blood (UCB)-derived mesenchymal stem cell (MSC) injection to regenerate a full-thickness subscapularis tendon tear in a rabbit model by evaluating the gross morphology and histology of the injected tendon and motion analysis of the rabbit's activity. At 4 weeks after ultrasound-guided UCB-derived MSC injection, 7 of the 10 full-thickness subscapularis tendon tears were only partial-thickness tears, and 3 remained full-thickness tendon tears. The tendon tear size and walking capacity at 4 weeks after UCB-derived MSC injection under ultrasound guidance were significantly improved compared with the same parameters immediately after tendon tear. UCB-derived MSC injection under ultrasound guidance without surgical repair or bioscaffold resulted in the partial healing of full-thickness rotator cuff tendon tears in a rabbit model. Histology revealed that UCB-derived MSCs induced regeneration of rotator cuff tendon tear and that the regenerated tissue was predominantly composed of type I collagens. In this study, ultrasound-guided injection of human UCB-derived MSCs contributed to regeneration of the full-thickness rotator cuff tendon tear without surgical repair. The results demonstrate the effectiveness of local injection of MSCs into the rotator cuff tendon. The results of this study suggest that ultrasound-guided umbilical cord blood-derived mesenchymal stem cell injection may be a useful conservative treatment for full-thickness rotator cuff tendon tear repair. ©AlphaMed Press.
Park, Gi-Young; Lee, Sang Chul
2015-01-01
Rotator cuff tendon tear is one of the most common causes of chronic shoulder pain and disability. In this study, we investigated the therapeutic effects of ultrasound-guided human umbilical cord blood (UCB)-derived mesenchymal stem cell (MSC) injection to regenerate a full-thickness subscapularis tendon tear in a rabbit model by evaluating the gross morphology and histology of the injected tendon and motion analysis of the rabbit’s activity. At 4 weeks after ultrasound-guided UCB-derived MSC injection, 7 of the 10 full-thickness subscapularis tendon tears were only partial-thickness tears, and 3 remained full-thickness tendon tears. The tendon tear size and walking capacity at 4 weeks after UCB-derived MSC injection under ultrasound guidance were significantly improved compared with the same parameters immediately after tendon tear. UCB-derived MSC injection under ultrasound guidance without surgical repair or bioscaffold resulted in the partial healing of full-thickness rotator cuff tendon tears in a rabbit model. Histology revealed that UCB-derived MSCs induced regeneration of rotator cuff tendon tear and that the regenerated tissue was predominantly composed of type I collagens. In this study, ultrasound-guided injection of human UCB-derived MSCs contributed to regeneration of the full-thickness rotator cuff tendon tear without surgical repair. The results demonstrate the effectiveness of local injection of MSCs into the rotator cuff tendon. Significance The results of this study suggest that ultrasound-guided umbilical cord blood-derived mesenchymal stem cell injection may be a useful conservative treatment for full-thickness rotator cuff tendon tear repair. PMID:26371340
Sebbag, Lionel; Park, Shin Ae; Kass, Philip H; Maggs, David J; Attar, Mayssa; Murphy, Christopher J
2017-07-01
To evaluate repeatability and reproducibility of tear osmolarity measured using the TearLab ™ osmometer in normal dogs and to assess its diagnostic potential in dogs with keratoconjunctivitis sicca (KCS). Beagle dogs; six normal and five with KCS. Tear osmolarity and Schirmer tear test-1 (STT-1) values were obtained at various times. Normal dogs were assessed for diurnal variation and repeatability and reproducibility of measurements. Dogs with KCS were evaluated before and after 5 months' topical twice-daily therapy with 2% cyclosporine. Mean ± SD tear osmolarity (mOsm/L) was significantly higher in normal dogs (337.4 ± 16.2) than in dogs with KCS before therapy (306.2 ± 18.0; P < 0.0001), but not following therapy with 2% cyclosporine (330.5 ± 13.7; P = 1.00). Osmolarity readings lower than 325.5 mOsm/L were suggestive of KCS (84.8% sensitivity and 87.1% specificity). In normal dogs, tear osmolarity readings were stable during the daytime (P = 0.99). Repeated measurements revealed high variability and typically poor-to-moderate repeatability and reproducibility, although this was improved by taking three successive measurements at each session. Considering combined data from all dogs, a positive correlation existed between STT-1 and tear osmolarity measurements (Pearson's correlation test, P = 0.04, r = 0.62). Canine tear osmolarity as determined by TearLab ™ osmometer was variable, required multiple readings to be informative, and differed from values reported for humans. Dogs with KCS had a lower tear osmolarity than did normal dogs, and this increased following cyclosporine therapy. © 2016 American College of Veterinary Ophthalmologists.
Fiske-Jackson, A R; Barker, W H J; Eliashar, E; Foy, K; Smith, R K W
2013-01-01
The sensitivity of ultrasonography for the diagnosis of manica flexoria (MF) tears within the digital flexor tendon sheath (DFTS) is lower than for diagnosis of marginal tears of the deep digital flexor tendon (DDFT). Additional diagnostic tools would assist in appropriate decision making for either conservative or surgical management. To evaluate the improvement in lameness of horses with MF or DDFT tears following intrathecal analgesia and to assess the sensitivity and specificity of contrast radiography for the diagnosis of these tears. The case records of horses presented to a referral clinic over a 7-year period that underwent intrathecal diagnostic analgesia, or intrathecal analgesia and contrast radiography, of the DFTS with subsequent tenoscopy were examined. Fifty-three limbs had intrathecal diagnostic analgesia performed and 23 contrast tenograms were assessed in horses undergoing DFTS tenoscopy. Horses with DDFT tears were significantly more likely to respond positively to intrathecal diagnostic analgesia than those with MF tears (P = 0.02). Using contrast radiography, tears of the MF were predicted with an overall sensitivity of 96% and specificity of 80%; marginal tears of the DDFT were predicted with an overall sensitivity of 57% and specificity of 84%. The results of intrathecal analgesia of the DFTS in combination with contrast radiography have a high sensitivity for predicting MF tears. The sensitivity of contrast radiography for predicting tears of the DDFT is lower but the specificity remains high. Contrast radiography performed at the same time as intrathecal analgesia provides useful information regarding the presence of MF tears and DDFT tears, which can assist in the decision of whether to manage the lameness conservatively or with tenoscopic evaluation. © 2012 EVJ Ltd.
Gene expression profiles of changes underlying different-sized human rotator cuff tendon tears.
Chaudhury, Salma; Xia, Zhidao; Thakkar, Dipti; Hakimi, Osnat; Carr, Andrew J
2016-10-01
Progressive cellular and extracellular matrix (ECM) changes related to age and disease severity have been demonstrated in rotator cuff tendon tears. Larger rotator cuff tears demonstrate structural abnormalities that potentially adversely influence healing potential. This study aimed to gain greater insight into the relationship of pathologic changes to tear size by analyzing gene expression profiles from normal rotator cuff tendons, small rotator cuff tears, and large rotator cuff tears. We analyzed gene expression profiles of 28 human rotator cuff tendons using microarrays representing the entire genome; 11 large and 5 small torn rotator cuff tendon specimens were obtained intraoperatively from tear edges, which we compared with 12 age-matched normal controls. We performed real-time polymerase chain reaction and immunohistochemistry for validation. Torn rotator cuff tendons demonstrated upregulation of a number of key genes, such as matrix metalloproteinase 3, 10, 12, 13, 15, 21, and 25; a disintegrin and metalloproteinase (ADAM) 12, 15, and 22; and aggrecan. Amyloid was downregulated in all tears. Small tears displayed upregulation of bone morphogenetic protein 5. Chemokines and cytokines that may play a role in chemotaxis were altered; interleukins 3, 10, 13, and 15 were upregulated in tears, whereas interleukins 1, 8, 11, 18, and 27 were downregulated. The gene expression profiles of normal controls and small and large rotator cuff tear groups differ significantly. Extracellular matrix remodeling genes were found to contribute to rotator cuff tear pathogenesis. Rotator cuff tears displayed upregulation of a number of matrix metalloproteinase (3, 10, 12, 13, 15, 21, and 25), a disintegrin and metalloproteinase (ADAM 12, 15, and 22) genes, and downregulation of some interleukins (1, 8, and 27), which play important roles in chemotaxis. These gene products may potentially have a role as biomarkers of failure of healing or therapeutic targets to improve tendon healing. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Updegrove, Gary F; Armstrong, April D; Mosher, Timothy J; Kim, H Mike
2015-11-01
To characterize the orientation of the normal supraspinatus central tendon and describe the displacement patterns of the central tendon in rotator cuff tears using a magnetic resonance imaging (MRI)-based method. We performed a retrospective MRI and chart review of 183 patients with a rotator cuff tear (cuff tear group), 52 with a labral tear but no rotator cuff tear (labral tear group), and 74 with a normal shoulder (normal group). The orientation of the supraspinatus central tendon relative to the bicipital groove was evaluated based on axial MRI and was numerically represented by the shortest distance from the lateral extension line of the central tendon to the bicipital groove. Tear size, fatty degeneration, and involvement of the anterior supraspinatus were evaluated to identify the factors associated with orientation changes. The mean distance from the bicipital groove to the central tendon line was 0.7 mm and 1.3 mm in the normal group and labral tear group, respectively. Full-thickness cuff tears involving the anterior supraspinatus showed a significantly greater distance (17.7 mm) than those sparing the anterior supraspinatus (4.9 mm, P = .001). Fatty degeneration of the supraspinatus was significantly correlated with the distance (P = .006). Disruption of the anterior supraspinatus and fatty degeneration of the supraspinatus were independent predictors of posterior displacement. The supraspinatus central tendon has a constant orientation toward the bicipital groove in normal shoulders, and the central tendon is frequently displaced posteriorly in full-thickness rotator cuff tears involving the anterior leading edge of the supraspinatus. The degree of posterior displacement is proportional to tear size and severity of fatty degeneration of the supraspinatus muscle. A simple and quick assessment of the central tendon orientation on preoperative MRI can be a useful indicator of tear characteristics, potentially providing insight into the intraoperative repair strategy. Level IV, diagnostic case-control study. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Comparison of the accuracy rates of 3-T and 1.5-T MRI of the knee in the diagnosis of meniscal tear.
Grossman, Jeffrey W; De Smet, Arthur A; Shinki, Kazuhiko
2009-08-01
The purpose of this study was to compare the accuracy of 3-T MRI with that of 1.5-T MRI of the knee in the diagnosis of meniscal tear and to analyze the causes of diagnostic error. We reviewed the medical records and original MRI interpretations of 100 consecutive patients who underwent 3-T MRI of the knee and of 100 consecutive patients who underwent 1.5-T MRI of the knee to determine the accuracy of diagnoses of meniscal tear. Knee arthroscopy was the reference standard. We retrospectively reviewed all MRI diagnostic errors to determine the cause of the errors. At arthroscopy, 109 medial and 77 lateral meniscal tears were identified in the 200 patients. With two abnormal MR images indicating a meniscal tear, the sensitivity and specificity for medial tear were 92.7% and 82.2% at 1.5-T MRI and 92.6% and 76.1% at 3-T MRI (p = 1.0, p = 0.61). The sensitivity and specificity for lateral tears were 68.4% and 95.2% at 1.5-T MRI and 69.2% and 91.8% at 3-T MRI (p = 1.0, p = 0.49). Of the false-positive diagnoses of medial meniscal tear, five of eight at 1.5 T and seven of 11 at 3 T were apparent peripheral longitudinal tears of the posterior horn. Fifteen of the 26 missed medial and lateral meniscal tears were not seen in retrospect even with knowledge of the tear type and location. Allowing for sample size limitations, we found comparable accuracy of 3-T and 1.5-T MRI of the knee in the diagnosis of meniscal tear. The causes of false-positive and false-negative MRI diagnoses of meniscal tear are similar for 3-T and 1.5-T MRI.
Assay of mucins in human tear fluid.
Spurr-Michaud, Sandra; Argüeso, Pablo; Gipson, Ilene
2007-05-01
Mucin genes, both secreted (MUC2, MUC5AC, MUC5B, MUC7) and membrane associated (MUC1, MUC4, MUC16), have been reported to be expressed by ocular surface epithelia. The purpose of this study was to comprehensively assay the mucin content of human tear fluid using multiple antibodies for each mucin and to develop a sensitive, semi-quantitative method for the assay of mucins in tears. Tear washes were obtained by instillation of saline onto the ocular surface, followed by collection from the inferior fornix. Tear proteins were separated in 1% agarose gels, transferred to nitrocellulose membrane by vacuum blotting and probed with multiple antibodies recognizing MUC1, MUC2, MUC4, MUC5AC, MUC5B, MUC7 and MUC16. Binding was detected using chemiluminescence, and quantity was determined by densitometry. Serial dilutions of pooled tears from normal individuals were assayed to determine the linear range of detectability. MUC1, MUC4, MUC16, MUC5AC and low levels of MUC2 were consistently detected in human tear fluid, while MUC5B and MUC7 were not. Use of several antibodies recognizing different epitopes on the same mucin confirmed these findings. The antibodies to mucins bound to serial dilutions of tears in a linear fashion (r2 > 0.9), indicating the feasibility of semi-quantitation. MUC5AC in tear fluid had an increased electrophoretic mobility compared to MUC5AC isolated from conjunctival tissue. This study provides clear evidence that the mucin component of tears is a mixture of secreted and shed membrane-associated mucins, and for the first time demonstrates MUC16 in tear fluid. Immunoblots of tears using agarose gel electrophoresis and chemiluminescence detection provide a semi-quantitative assay for mucin protein that will be useful for comparisons with tears from diseased eyes or after pharmacological intervention.
Assay of Mucins in Human Tear Fluid
Spurr-Michaud, Sandra; Argüeso, Pablo; Gipson, Ilene
2007-01-01
Mucin genes, both secreted (MUC2, MUC5AC, MUC5B, MUC7) and membrane associated (MUC1, MUC4, MUC16), have been reported to be expressed by ocular surface epithelia. The purpose of this study was to comprehensively assay the mucin content of human tear fluid using multiple antibodies for each mucin and to develop a sensitive, semi-quantitative method for the assay of mucins in tears. Tear washes were obtained by instillation of saline onto the ocular surface, followed by collection from the inferior fornix. Tear proteins were separated in 1% agarose gels, transferred to nitrocellulose membrane by vacuum blotting and probed with multiple antibodies recognizing MUC1, MUC2, MUC4, MUC5AC, MUC5B, MUC7 and MUC16. Binding was detected using chemiluminescence, and quantity was determined by densitometry. Serial dilutions of pooled tears from normal individuals were assayed to determine the linear range of detectability. MUC1, MUC4, MUC16, MUC5AC and low levels of MUC2 were consistently detected in human tear fluid, while MUC5B and MUC7 were not. Use of several antibodies recognizing different epitopes on the same mucin confirmed these findings. The antibodies to mucins bound to serial dilutions of tears in a linear fashion (r2 >0.9), indicating the feasibility of semi-quantitation. MUC5AC in tear fluid had an increased electrophoretic mobility compared to MUC5AC isolated from conjunctival tissue. This study provides clear evidence that the mucin component of tears is a mixture of secreted and shed membrane-associated mucins, and for the first time demonstrates MUC16 in tear fluid. Immunoblots of tears using agarose gel electrophoresis and chemiluminescence detection provide a semi-quantitative assay for mucin protein that will be useful for comparisons with tears from diseased eyes or after pharmacological intervention. PMID:17399701
Evaluation of the Effects of Conjunctivochalasis Excision on Tear Stability and Contrast Sensitivity
Qiu, Weiqiang; Zhang, Mingzhou; Xu, Ting; Liu, Ziyuan; Lv, Huibin; Wang, Wei; Li, Xuemin
2016-01-01
Conjunctivochalasis (CCh) disrupts tear flow and damages tear film stability. This study sought to evaluate the tear stability and contrast sensitivity of patients with CCh on whom CCh excision was performed. The study included 39 eyes from 39 patients; all patients had eyes with grade 2 or 3 CCh, underwent CCh excision, and were evaluated before and three months after the surgery. The evaluated variables included the ocular surface disease index (OSDI), the tear break-up time (TBUT), corneal fluorescein staining, corneal surface irregularity, Schirmer’s I test, the tear meniscus area (TMA), and contrast sensitivity. A follow-up of three months was achieved in 36 eyes for 36 patients. All parameters improved significantly after surgery (p < 0.05), except Schirmer’s I test, thus suggesting that CCh excision is an effective method for reconstructing the lower tear meniscus and improving both tear film stability and corneal surface irregularity. The results further demonstrated a simultaneous increase in contrast sensitivity after surgery. PMID:27892479
Diagnosis of dry eye disease and emerging technologies
Zeev, Maya Salomon-Ben; Miller, Darby Douglas; Latkany, Robert
2014-01-01
Dry eye is one of the most commonly encountered problems in ophthalmology. Signs can include punctate epithelial erosions, hyperemia, low tear lakes, rapid tear break-up time, and meibomian gland disease. Current methods of diagnosis include a slit-lamp examination with and without different stains, including fluorescein, rose bengal, and lissamine green. Other methods are the Schirmer test, tear function index, tear break-up time, and functional visual acuity. Emerging technologies include meniscometry, optical coherence tomography, tear film stability analysis, interferometry, tear osmolarity, the tear film normalization test, ocular surface thermography, and tear biomarkers. Patient-specific considerations involve relevant history of autoimmune disease, refractive surgery or use of oral medications, and allergies or rosacea. Other patient considerations include clinical examination for lid margin disease and presence of lagophthalmos or blink abnormalities. Given a complex presentation and a variety of signs and symptoms, it would be beneficial if there was an inexpensive, readily available, and reproducible diagnostic test for dry eye. PMID:24672224
Harryman, Douglas T; Hettrich, Carolyn M; Smith, Kevin L; Campbell, Barry; Sidles, John A; Matsen, Frederick A
2003-04-01
Rotator cuff tears are among the most common conditions of the shoulder. One of the major difficulties in studying patients with rotator cuff tears is that the clinical expression of these tears varies widely and different practices may have substantially different patient populations. The goals of the present prospective multipractice study were to use patient self-assessment questionnaires (1) to identify some of the characteristics of patients with rotator cuff tears, other than the size of the cuff tear, that are correlated with shoulder function, and (2) to determine whether there are significant differences in these characteristics among patients from the practices of different surgeons. Ten surgeons enrolled a total of 333 patients with a full-thickness tear of the supraspinatus tendon into this prospective study. Each patient completed self-assessment questionnaires that included items regarding demographic characteristics, prior treatment, medical and social comorbidities, general health status, and shoulder function. As expected, patients who had an infraspinatus tendon tear as well as a supraspinatus tendon tear had significantly worse ability to use the arm overhead compared with those who had a supraspinatus tear alone (p < 0.005). However, shoulder function and health status were correlated with patient characteristics other than the size of the rotator cuff tear. The number of shoulder functions that were performable was correlated with the subscales of the Short Form-36 and was inversely associated with medical and social comorbidities. The patients from the ten different surgeon practices showed significant differences in almost every parameter, including age, gender, method of tear documentation, tear size, prior treatment, medical and social comorbidities, general health status, and shoulder function. Clinical studies on the natural history of rotator cuff tears and the effectiveness of treatment must control for a wide range of variables, many of which do not pertain directly to the shoulder. Patients from the practices of different surgeons cannot be assumed to be similar with respect to these variables. Patient self-assessment questionnaires appear to offer a practical method of uniform assessment across different practices.
Measurement of Tear Production in English Angora and Dutch Rabbits
Rajaei, Seyed Mehdi; Rafiee, Siamak Mashhady; Ghaffari, Masoud Selk; Masouleh, Mohammad N; Jamshidian, Mahmoud
2016-01-01
The purpose of this study was to establish normal values for tear production tests in different breeds of domestic rabbits. Healthy adult rabbits (n = 60; 120 eyes) of 2 different breeds (English angora and Dutch; n = 15 of each sex and breed) were used in this study. Tear production was measured by using the 1-min Schirmer tear test (STT), phenol red thread test (PRTT), and endodontic absorbent paper point tear test (EAPTT). In addition, horizontal palpebral fissure length was evaluated as a measure of ocular adnexal dimensions. Tear production (mean ± 1 SD) in English angora rabbits was 5.4 ± 1.6 mm/min according to the STT, 25.0 ± 2.7 mm in 15 s for the PRTT, and 18.8 ± 2.1 mm/min by the EAPTT; in Dutch rabbits, these values were 4.6 ± 1.2 mm/min, 23.6 ± 2.3 mm in 15 s, and 16.9 ± 1.7 mm/min, respectively. Only the EAPTT revealed a significant difference in tear production between English Angora and Dutch rabbits. These results provide reference values for tear production in English Angora and Dutch rabbits according to 3 different quantitative tear film assessment methods. PMID:27025815
Effect of topical ophthalmic epinastine and olopatadine on tear volume in mice.
Villareal, Arturo L; Farley, William; Pflugfelder, Stephen C
2006-12-01
To investigate the effects of topical epinastine and olopatadine on tear volume by using a mouse model. Eighty-five C57BL6 mice (170 eyes) were treated twice daily with topical ophthalmic epinastine 0.05%, olopatadine 0.1%, or atropine 1% or served as untreated controls. A thread-wetting assay was used to measure tear volume at baseline and 15, 45, 90, 120, and 240 minutes after the last instillation of the drug on days 2 and 4 of treatment. After 2 days of treatment, epinastine-treated mice showed greater mean tear volumes than olopatadine-treated mice did at 15, 45, 90, and 240 minutes, with statistical significance at 15 and 45 minutes (P<0.001). Olopatadine significantly reduced tear volume versus untreated controls at 15 and 45 minutes (P<0.001). After 4 days, tear volumes with epinastine treatment exceeded those with olopatadine treatment at all time points, with statistical significance at 45 minutes (P<0.05). Atropine rendered tears undetectable at 15, 45, and 90 minutes; tear volume returned to baseline levels at 240 minutes. Topical epinastine did not inhibit tear secretion, whereas olopatadine caused a significant decrease in tear volume. Because of its neutral impact on the lacrimal functional unit, epinastine may be an especially good choice for the treatment of allergic conjunctivitis in patients with dry eye disease or in those who are at risk for developing dry eye.
Effects of tear film dynamics on quality of vision.
Koh, Shizuka; Tung, Cynthia I; Inoue, Yasushi; Jhanji, Vishal
2018-06-15
The precorneal tear film is maintained by blinking and exhibits different phases in the tear cycle. The tear film serves as the most anterior surface of the eye and plays an important role as a first refractive component of the eye. Alterations in tear film dynamics may cause both vision-related and ocular surface-related symptoms. Although the optical quality associated with the tear film dynamics previously received little attention, objective measurements of optical quality using wavefront sensors have enabled us to quantify optical aberrations induced by the tear film. This has provided an objective method for assessing reduced optical quality in dry eye; thus, visual disturbances were included in the definition of dry eye disease in the 2007 Dry Eye Workshop report. In addition, sequential measurements of wavefront aberrations have provided us with valuable insights into the dynamic optical changes associated with tear film dynamics. This review will focus on the current knowledge of the mechanisms of wavefront variations that are caused by different aspects of tear film dynamics: specifically, quality, quantity and properties of the tear film, demonstrating the respective effects of dry eye, epiphora and instillation of eye drops on the quality of vision. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Lipid peroxidation is increased in tears from the elderly.
Benlloch-Navarro, Soledad; Franco, Ilenia; Sánchez-Vallejo, Violeta; Silvestre, Dolores; Romero, Francisco Javier; Miranda, María
2013-10-01
We describe a procedure in which tears, obtained from Schirmer strips, are used to measure a marker of lipid peroxidation, malondialdehyde (MDA). We also compared the levels of proteins and MDA in tears from two groups of people: young adults (18-30 years old) and elderly adults (65-85 years old), because the data related to total protein concentration of human tears vary widely and because the majority of people over the age of 65 experience some symptoms of dry eyes and this condition has been recognized as an oxidative stress-induced disease. Our results show a significant difference in the protein concentration of the tears taken from the two age categories, younger adults (18-30 years old) and older adults (65-85 years old). Herein, we report for the first time an increase in MDA concentrations determined by HPLC in human tears based on age. It is possible that alterations in the tear lipid layer may lead to an increase in lipid peroxidation. Further studies are needed to understand the nature and function of tear film and stability in order to obtain new methods to analyze tears in patients with different diseases. In this sense, it would be interesting to compare MDA concentration in tears from control subjects and from people with meibomian gland dysfunction. Copyright © 2013 Elsevier Ltd. All rights reserved.
Chiva, Andreea
2011-08-15
Dry eye is the most prevalent condition seen by the ophthalmologist, in particular in elderly. The identification of new common risk factors (computer use and contact lens wear) extends the disease among the young people. The early diagnosis of dry eye is essential, but difficult, because the biochemical changes in tear film usually occur before any detectable signs. Due its advantages, electrophoresis of tear proteins could be an important tool for diagnosis of tear film impairment in high risk groups for dry eye. The role of tear proteins electrophoresis in early diagnosis of dry eye related to computer use and contact lens wear, as well as the biochemical changes in these high risk groups are presented. This review will summarize the actual data concerning the electrophoretic changes of tear proteins in computer users and contact lens wearers, two common high risk groups for dry eye. Electrophoresis of tear proteins using automated system Hyrys-Hydrasys SEBIA France is an important tool for early diagnosis of tear film alterations and monitoring of therapy. The quantification of many proteins in a single analysis using a small quantity of unconcentrated reflex tears is the main advantage of this technique. Electrophoresis of tear proteins should became a prerequisite, in particular for computer users less than 3 h/day, as well as at prescribing contact lenses.
Park, Sang-Jun
2015-01-01
Purpose To investigate the incidence of root tears of the posterior horn of the medial meniscus in total knee replacement arthroplasty for knee osteoarthritis and retrospectively analyze clinical results and factors associated with root tears. Materials and Methods There were 197 knees of 140 enrolled patients who had undergone total knee replacement arthroplasty between September 2010 and May 2014. The presence of a root tear of the posterior horn of the medial meniscus was confirmed in all patients. Statistical analysis was performed to investigate the correlation between root tears and the possible factors of meniscal tears including gender, age, severity of symptoms (visual analogue scale [VAS] score and medial joint line tenderness), grade of osteoarthritis (Kellgren-Lawrence grading scale), body mass index (BMI), varus deformity, and mechanical axis deviation. Results Meniscal tears were observed in 154 knees (78.17%). The root tear had correlation with the severity of osteoarthritis (p<0.05), varus deformity (p<0.05), mechanical axis deviation (p<0.05), and BMI (p<0.05). Conclusions Factors considered to represent the severity of osteoarthritis were found to be associated with root tears of the medial meniscus posterior horn. Increased BMI seemed to be associated with the increased incidence of root tears of the medial meniscus posterior horn. PMID:26060607
Preexisting Rotator Cuff Tears as a Predictor of Outcomes in National Football League Athletes.
Gibbs, Daniel B; Lynch, T Sean; Gombera, M Mustafa; Saltzman, Matthew D; Nuber, Gordon W; Schroeder, Gregory D; Labelle, Mark; Hollett, Brian P
A preexisting rotator cuff tear may affect the draft status and career performance of National Football League (NFL) players. Preexisting rotator cuff tears decrease a player's draft status, performance, and longevity in the NFL. Retrospective cohort study. Level 3. Medical reports of prospective NFL players during the NFL Scouting Combine from 2003 to 2011 were evaluated to identify players with a previous rotator cuff tear. Athletes were matched to control draftees without documented shoulder pathology by age, position, year drafted, and round drafted. Career statistics and performance scores were calculated. Between 2003 and 2011, 2965 consecutive athletes were evaluated. Forty-nine athletes had preexisting rotator cuff tears: 22 athletes underwent surgical intervention for their tear and 27 were treated nonoperatively. Those with a rotator cuff tear were significantly less likely to be drafted than those without a previous injury (55.1% vs 77.5%, P = 0.002). The 27 drafted athletes with preexisting rotator cuff tears started significantly fewer games (23.7 vs 43.0, P = 0.02) and played significantly fewer years (4.3 vs 5.7, P = 0.04) and significantly fewer games (47.1 vs 68.4, P = 0.04) than matched control athletes without rotator cuff tears. Athletes with a preexisting rotator cuff tear were less likely to be drafted and had decreased career longevity.
Chronic Degeneration Leads to Poor Healing of Repaired Massive Rotator Cuff Tears in Rats.
Killian, Megan L; Cavinatto, Leonardo M; Ward, Samuel R; Havlioglu, Necat; Thomopoulos, Stavros; Galatz, Leesa M
2015-10-01
Chronic rotator cuff tears present a clinical challenge, often with poor outcomes after surgical repair. Degenerative changes to the muscle, tendon, and bone are thought to hinder healing after surgical repair; additionally, the ability to overcome degenerative changes after surgical repair remains unclear. The purpose of this study was to evaluate healing outcomes of muscle, tendon, and bone after tendon repair in a model of chronic rotator cuff disease and to compare these outcomes to those of acute rotator cuff injuries and repair. The hypothesis was that degenerative rotator cuff changes associated with chronic multitendon tears and muscle unloading would lead to poor structural and mechanical outcomes after repair compared with acute injuries and repair. Controlled laboratory study. Chronic rotator cuff injuries, induced via detachment of the supraspinatus (SS) and infraspinatus (IS) tendons and injection of botulinum toxin A into the SS and IS muscle bellies, were created in the shoulders of rats. After 8 weeks of injury, tendons were surgically reattached to the humeral head, and an acute, dual-tendon injury and repair was performed on the contralateral side. After 8 weeks of healing, muscles were examined histologically, and tendon-to-bone samples were examined microscopically, histologically, and biomechanically and via micro-computed tomography. All repairs were intact at the time of dissection, with no evidence of gapping or ruptures. Tendon-to-bone healing after repair in our chronic injury model led to reduced bone quality and morphological disorganization at the repair site compared with acute injuries and repair. SS and IS muscles were atrophic at 8 weeks after repair of chronic injuries, indicating incomplete recovery after repair, whereas SS and IS muscles exhibited less atrophy and degeneration in the acute injury group at 8 weeks after repair. After chronic injuries and repair, humeral heads had decreased total mineral density and an altered trabecular structure, and the repair had decreased strength, stiffness, and toughness, compared with the acute injury and repair group. Chronic degenerative changes in rotator cuff muscles, tendons, and bone led to inferior healing characteristics after repair compared with acute injuries and repair. The changes were not reversible after repair in the time course studied, consistent with clinical impressions. High retear rates after rotator cuff repair are associated with tear size and chronicity. Understanding the mechanisms behind this association may allow for targeted tissue therapy for tissue degeneration that occurs in the setting of chronic tears. © 2015 The Author(s).
Chronic Degeneration Leads to Poor Healing of Repaired Massive Rotator Cuff Tears in Rats
Killian, Megan L.; Cavinatto, Leonardo M.; Ward, Samuel R.; Havlioglu, Necat; Thomopoulos, Stavros; Galatz, Leesa M.
2016-01-01
Background Chronic rotator cuff tears present a clinical challenge, often with poor outcomes after surgical repair. Degenerative changes to the muscle, tendon, and bone are thought to hinder healing after surgical repair; additionally, the ability to overcome degenerative changes after surgical repair remains unclear. Purpose/Hypothesis The purpose of this study was to evaluate healing outcomes of muscle, tendon, and bone after tendon repair in a model of chronic rotator cuff disease and to compare these outcomes to those of acute rotator cuff injuries and repair. The hypothesis was that degenerative rotator cuff changes associated with chronic multitendon tears and muscle unloading would lead to poor structural and mechanical outcomes after repair compared with acute injuries and repair. Study Design Controlled laboratory study. Methods Chronic rotator cuff injuries, induced via detachment of the supraspinatus (SS) and infraspinatus (IS) tendons and injection of botulinum toxin A into the SS and IS muscle bellies, were created in the shoulders of rats. After 8 weeks of injury, tendons were surgically reattached to the humeral head, and an acute, dual-tendon injury and repair was performed on the contralateral side. After 8 weeks of healing, muscles were examined histologically, and tendon-to-bone samples were examined microscopically, histologically, and biomechanically and via micro–computed tomography. Results All repairs were intact at the time of dissection, with no evidence of gapping or ruptures. Tendon-to-bone healing after repair in our chronic injury model led to reduced bone quality and morphological disorganization at the repair site compared with acute injuries and repair. SS and IS muscles were atrophic at 8 weeks after repair of chronic injuries, indicating incomplete recovery after repair, whereas SS and IS muscles exhibited less atrophy and degeneration in the acute injury group at 8 weeks after repair. After chronic injuries and repair, humeral heads had decreased total mineral density and an altered trabecular structure, and the repair had decreased strength, stiffness, and toughness, compared with the acute injury and repair group. Conclusion Chronic degenerative changes in rotator cuff muscles, tendons, and bone led to inferior healing characteristics after repair compared with acute injuries and repair. The changes were not reversible after repair in the time course studied, consistent with clinical impressions. Clinical Relevance High retear rates after rotator cuff repair are associated with tear size and chronicity. Understanding the mechanisms behind this association may allow for targeted tissue therapy for tissue degeneration that occurs in the setting of chronic tears. PMID:26297522
Corneal Sensitivity in Tear Dysfunction and its Correlation with Clinical Parameters and Blink Rate
Rahman, Effie Z.; Lam, Peter K.; Chu, Chia-Kai; Moore, Quianta; Pflugfelder, Stephen C.
2015-01-01
Purpose To compare corneal sensitivity in tear dysfunction due to a variety of causes using contact and non-contact esthesiometers and to evaluate correlations between corneal sensitivity, blink rate and clinical parameters. Design Comparative observational case series. Methods Ten normal and 33 subjects with tear dysfunction [meibomian gland disease (n = 11), aqueous tear deficiency (n = 10) - without (n = 7) and with (n = 3) Sjögren syndrome (SS) and conjunctivochalasis (n = 12)] were evaluated. Corneal sensitivity was measured with Cochet-Bonnet and air jet esthesiometers and blink rate by electromyelography. Eye irritation symptoms, tear meniscus height, tear break-up time (TBUT), and corneal and conjunctival dye staining were measured. Between group means were compared and correlations calculated. Results Compared with control (Cochet-Bonnet 5.45 mm, air esthesiometer 3.62 mg), mean sensory thresholds were significantly higher in aqueous tear deficiency using either Cochet-Bonnet (3.6 mm; P = 0.003) or air (11.7 mg; P = 0.046) esthesiometers, but were not significantly different in the other groups. Reduced corneal sensitivity significantly correlated with more rapid TBUT and blink rate, and greater irritation and ocular surface dye staining with one or both esthesiometers. Mean blink rates were significantly higher in both aqueous tear deficiency and conjunctivochalasis compared with control. Among all subjects, blink rate positively correlated with ocular surface staining and irritation and inversely correlated with TBUT. Conclusion Amongst conditions causing tear dysfunction, reduced corneal sensitivity is associated with greater irritation, tear instability, ocular surface disease and blink rate. Rapid blinking is associated with worse ocular surface disease and tear stability. PMID:26255576
Diagnostic performance of indirect MR arthrography for the diagnosis of rotator cuff tears at 3.0 T.
Lee, Ji Hyun; Yoon, Young Cheol; Jee, Sukkyung
2015-06-01
Indirect magnetic resonance (MR) arthrography is a non-invasive method for shoulder imaging. However, there are no studies that have examined the diagnostic performance of indirect MR arthrography for the diagnosis of rotator cuff tears in a large patient population. To assess the diagnostic performance of indirect fast spin-echo (FSE) MR arthrography for the diagnosis of rotator cuff tears at 3.0 T. A total of 149 patients who had undergone indirect shoulder MR arthrography followed by arthroscopic surgery were enrolled in this retrospective study. Two musculoskeletal radiologists evaluated images from each patient for the presence of supraspinatus-infraspinatus (SSP-ISP) or subscapularis (SSC) tendon tears. Using the arthroscopic findings as the reference standard, the overall diagnostic performance and detection rates for SSP-ISP and SSC tendon tears were calculated. The sensitivity, specificity, and accuracy of readers I and II for the diagnosis of SSP-ISP tendon tears were 94% and 95%, 89% and 85%, and 93% and 93%, respectively. The sensitivity of imaging for detection of SSP-ISP tendon tears by readers I and II were 100% and 100% for full-thickness tears and 84% and 86% for partial-thickness tears, respectively. The sensitivity, specificity, and accuracy of readers I and II for the diagnosis of SSC tendon tears were 80% and 76%, 89% and 93%, and 85% and 85%, respectively. Indirect MR arthrography is useful for the detection of SSP-ISP and SSC tendon tears. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
NASA Astrophysics Data System (ADS)
Sabau, Adrian S.; Mirmiran, Seyed; Glaspie, Christopher; Li, Shimin; Apelian, Diran; Shyam, Amit; Allen Haynes, J.; Rodriguez, Andres F.
2018-06-01
The hot-tearing resistance of multicomponent Al-Cu alloys during permanent mold casting was investigated using a constrained permanent mold in which the load and temperature were measured. The nominal Cu composition was varied from 5 to 8 wt pct. Casting experiments were conducted without adding any grain-refining inoculants. The following variables, which were obtained from the measured load data during casting, were considered to assess the hot-tearing resistance of the Al-Cu multicomponent alloys: "V"-like signature in the load rate variation, load at solidus point, and load rate average over the freezing range. In addition, a hot-tearing criterion based on the variation of the fraction of solid in the late stages of solidification was used. It was found that all criteria considered can accurately predict the alloys with the lowest and highest hot-tear resistance, respectively. It was found that the rate of measured load during casting could be used to indicate substantial hot tearing. However, the load rate variation could not be used to detect when small hot tears were present. Among all the criteria considered, the load at the solidus point shows an excellent agreement with experimentally observed hot-tearing resistance for all but one alloy. The poorly resistant hot-tearing alloys exhibited mainly coarse columnar grains while the most hot-tearing resistant alloys exhibited a much more refined grain microstructure. This is the first study in which good hot-tear resistance is demonstrated for multicomponent Al-Cu alloys with nominal Cu content greater than 7 wt pct.
Begley, Carolyn; Simpson, Trefford; Liu, Haixia; Salvo, Eliza; Wu, Ziwei; Bradley, Arthur; Situ, Ping
2013-04-12
The purpose of this study was to test the association between tear film fluorescence changes during tear break-up (TBU) or thinning and the concurrent ocular sensory response. Sixteen subjects kept one eye open as long as possible (MBI), indicated their discomfort level continuously, and rated ocular sensations of irritation, stinging, burning, pricking, and cooling using visual analog scales (VAS). Fluorescence of the tear film was quantified by a pixel-based analysis of the median pixel intensity (PI), TBU, and percentage of dark pixels (DarkPix) over time. A cutoff of 5% TBU was used to divide subjects into either break-up (BU) or minimal break-up (BUmin) groups. Tear film fluorescence decreased (median PI) and the percentage of TBU and DarkPix increased in all trials, with the rate significantly greater in the BU than the BUmin group (Mann-Whitney U test, P < 0.05). The rate of increasing discomfort during trials was highly correlated with the rate of decrease in median PI and developing TBU (Spearman's, r ≥ 0.70). Significant correlations were found between corneal fluorescence, MBI, and sensory measures. Concentration quenching of fluorescein dye with tear film thinning best explains decreasing tear film fluorescence during trials. This was highly correlated with increasing ocular discomfort, suggesting that both tear film thinning and TBU stimulate underlying corneal nerves, although TBU produced more rapid stimulation. Slow increases in tear film hyperosmolarity may cause the gradual increase in discomfort during slow tear film thinning, whereas the sharp increases in discomfort during TBU suggest a more complex stimulus.
Dynamics and function of the tear film in relation to the blink cycle.
Braun, R J; King-Smith, P E; Begley, C G; Li, Longfei; Gewecke, N R
2015-03-01
Great strides have recently been made in quantitative measurements of tear film thickness and thinning, mathematical modeling thereof and linking these to sensory perception. This paper summarizes recent progress in these areas and reports on new results. The complete blink cycle is used as a framework that attempts to unify the results that are currently available. Understanding of tear film dynamics is aided by combining information from different imaging methods, including fluorescence, retroillumination and a new high-speed stroboscopic imaging system developed for studying the tear film during the blink cycle. During the downstroke of the blink, lipid is compressed as a thick layer just under the upper lid which is often released as a narrow thick band of lipid at the beginning of the upstroke. "Rippling" of the tear film/air interface due to motion of the tear film over the corneal surface, somewhat like the flow of water in a shallow stream over a rocky streambed, was observed during lid motion and treated theoretically here. New mathematical predictions of tear film osmolarity over the exposed ocular surface and in tear breakup are presented; the latter is closely linked to new in vivo observations. Models include the effects of evaporation, osmotic flow through the cornea and conjunctiva, quenching of fluorescence, tangential flow of aqueous tears and diffusion of tear solutes and fluorescein. These and other combinations of experiment and theory increase our understanding of the fluid dynamics of the tear film and its potential impact on the ocular surface. Copyright © 2014 Elsevier Ltd. All rights reserved.
Impact of environmental adaptation on tear film assessments.
Fagehi, R
2018-03-01
The purpose of this study was to investigate the effect of ocular environmental adaptation on clinical tear film assessment. Thirty subjects (male, mean age 23±2.5) participated in this study. A number of clinical tear film tests were applied, including: fluorescein tear break-up time (FTBUT), Schirmer test and tear prism height test (TPH). The tear physiology of each subject was evaluated twice, once immediately when they arrived from the external environment, and then after 30minutes adaptation in the exam room environment. The mean values were: Schirmer test A (22.1±2.99), Schirmer test B (24.2±2.63), FTBUT A (8.00±1.94), FTBUT B (9.13±2.04), TPH A (0.179±0.026) and TPH B* (0.187±0.023). Statistical testing using Wilcoxon-signed rank test showed a significant difference between the Schirmer test results measured at the different times (P=0.008). Also, the FTBUT and tear prism height test results showed significant differences between the two evaluation times, (P=0.001, 0.011, respectively) (A: tear assessed when the subject comes from the outside environment, B: tear film assessed after 30min adaptation in the clinical environment). This study showed a significant difference between the tear film test results evaluated when the subjects were assessed immediately from the outside environment and after an adaptation time in the clinic environment. Practitioners must consider the effect of differences between external and clinical environment adaptation on clinical tear film physiology. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Dynamics and function of the tear film in relation to the blink cycle
Braun, R.J.; King-Smith, P.E.; Begley, C.G.; Li, Longfei; Gewecke, N.R.
2014-01-01
Great strides have recently been made in quantitative measurements of tear film thickness and thinning, mathematical modeling thereof and linking these to sensory perception. This paper summarizes recent progress in these areas and reports on new results. The complete blink cycle is used as a framework that attempts to unify the results that are currently available. Understanding of tear film dynamics is aided by combining information from different imaging methods, including fluorescence, retroillumination and a new high-speed stroboscopic imaging system developed for studying the tear film during the blink cycle. During the downstroke of the blink, lipid is compressed as a thick layer just under the upper lid which is often released as a narrow thick band of lipid at the beginning of the upstroke. “Rippling” of the tear film/air interface due to motion of the tear film over the corneal surface, somewhat like the flow of water in a shallow stream over a rocky streambed, was observed during lid motion and treated theoretically here. New mathematical predictions of tear film osmolarity over the exposed ocular surface and in tear breakup are presented; the latter is closely linked to new in vivo observations. Models include the effects of evaporation, osmotic flow through the cornea and conjunctiva, quenching of fluorescence, tangential flow of aqueous tears and diffusion of tear solutes and fluorescein. These and other combinations of experiment and theory increase our understanding of the fluid dynamics of the tear film and its potential impact on the ocular surface. PMID:25479602
Oxidative Stress Measures of Lipid and DNA Damage in Human Tears.
Haworth, Kristina M; Chandler, Heather L
2017-05-01
We evaluate feasibility and repeatability of measures for lipid peroxidation and DNA oxidation in human tears, as well as relationships between outcome variables, and compared our findings to previously reported methods of evaluation for ocular sun exposure. A total of 50 volunteers were seen for 2 visits 14 ± 2 days apart. Tear samples were collected from the inferior tear meniscus using a glass microcapillary tube. Oxidative stress biomarkers were quantified using enzyme-linked immunosorbent assay (ELISA): lipid peroxidation by measurement of hexanoyl-lysine (HEL) expression; DNA oxidation by measurement of 8-oxo-2'-deoxyguinosone (8OHdG) expression. Descriptive statistics were generated. Repeatability estimates were made using Bland-Altman plots with mean differences and 95% limits of agreement were calculated. Linear regression was conducted to evaluate relationships between measures. Mean (±SD) values for tear HEL and 8OHdG expression were 17368.02 (±9878.42) nmol/L and 66.13 (±19.99) ng/mL, respectively. Repeatability was found to be acceptable for both HEL and 8OHdG expression. Univariate linear regression supported tear 8OHdG expression and spring season of collection to be predictors of higher tear HEL expression; tear HEL expression was confirmed as a predictor of higher tear 8OHdG expression. We demonstrate feasibility and repeatability of estimating previously unreported tear 8OHdG expression. Seasonal temperature variation and other factors may influence tear lipid peroxidation. Support is demonstrated to suggest lipid damage and DNA damage occur concurrently on the human ocular surface.
Borderie, Vincent M; Gineys, Raquel; Goldschmidt, Pablo; Batellier, Laurence; Laroche, Laurent; Chaumeil, Christine
2012-11-01
To assess the clinical relevance of tear anti-herpes simplex virus (HSV) antibody measurement for the diagnosis of herpes simplex keratitis. Records of 364 patients clinically suspect of HSV-related keratitis who had tear anti-HSV IgG assessment (tear-quantified anti-HSV IgG/filtrated IgG ratio) in our institution between January 2000 and August 2008 were retrospectively analyzed. Patients were classified into 4 groups as follows: group 1, anti-HSV IgG negative in serum and tears; group 2, anti-HSV IgG negative in tears and positive in serum; group 3, anti-HSV IgG nonsignificantly positive in tears and positive in serum; and group 4, anti-HSV IgG significantly positive in serum and tears. Randomly selected patient charts from each group were reviewed for clinical data. The prevalence of anti-HSV IgG in blood increased with age from >70% before 20 years to 95% after 70 years. The prevalence of anti-HSV IgG in tears increased with age from 20% before 20 years to >50% after 70 years. The presence (either significant or not) of anti-HSV IgG in tears was significantly associated with decreased corneal sensation, presence of stromal opacities, and with neurotrophic keratitis. Logistic regression showed no significant association between age and clinical signs except for herpetic ulcers and herpetic necrotizing keratitis. Tear production of anti-HSV IgG increases with age, and it is associated with sequelae of herpes simplex keratitis. Conversely, it is poorly associated with clinical signs of acute herpes simplex keratitis.
Antimicrobial Compounds in Tears
McDermott, Alison M.
2013-01-01
The tear film coats the cornea and conjunctiva and serves several important functions. It provides lubrication, prevents drying of the ocular surface epithelia, helps provide a smooth surface for refracting light, supplies oxygen and is an important component of the innate defense system of the eye providing protection against a range of potential pathogens. This review describes both classic antimicrobial compounds found in tears such as lysozyme and some more recently identified such as members of the cationic antimicrobial peptide family and surfactant protein-D as well as potential new candidate molecules that may contribute to antimicrobial protection. As is readily evident from the literature review herein, tears, like all mucosal fluids, contain a plethora of molecules with known antimicrobial effects. That all of these are active in vivo is debatable as many are present in low concentrations, may be influenced by other tear components such as the ionic environment, and antimicrobial action may be only one of several activities ascribed to the molecule. However, there are many studies showing synergistic/additive interactions between several of the tear antimicrobials and it is highly likely that cooperativity between molecules is the primary way tears are able to afford significant antimicrobial protection to the ocular surface in vivo. In addition to effects on pathogen growth and survival some tear components prevent epithelial cell invasion and promote the epithelial expression of innate defense molecules. Given the protective role of tears a number of scenarios can be envisaged that may affect the amount and/or activity of tear antimicrobials and hence compromise tear immunity. Two such situations, dry eye disease and contact lens wear, are discussed here. PMID:23880529
Shinagawa, Kiyotsugu; Hatta, Taku; Yamamoto, Nobuyuki; Kawakami, Jun; Shiota, Yuki; Mineta, Mitsuyoshi; Itoi, Eiji
2018-05-03
Focus has recently been on the critical shoulder angle (CSA) as a factor related to rotator cuff tear and osteoarthritis (OA) in the European population. However, whether this relationship is observed in the Asian population is unclear. The correlation between the CSAs measured on anteroposterior radiographs and the presence or absence of rotator cuff tears or OA changes was assessed in 295 patients. Rotator cuff tears were diagnosed with magnetic resonance imaging or ultrasonography. OA findings were classified using the Samilson-Prieto classification. The CSAs among the patients with rotator cuff tears, OA changes, and those without pathologies were compared. Multivariable analyses were used to clarify the potential risks for these pathologies. The mean CSA with rotator cuff tear (33.9° ± 4.1°) was significantly greater than that without a rotator cuff tear (32.3° ± 4.5°; P = .002). Multivariable analysis also showed that a greater CSA had a significantly increased risk of rotator cuff tears, with the odds ratio of 1.08 per degree. OA findings showed no significant correlation to the CSAs. Our study demonstrates that the CSA is greater in those with a rotator cuff tear than in those without a tear or OA changes, which may be an independent risk factor for the incidence of rotator cuff tears in the Japanese population. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Relationship of ABO Blood Type on Rotator Cuff Tears.
Lee, Doo-Hyung; Lee, Han-Dong; Yoon, Seung-Hyun
2015-11-01
ABO blood groups are associated with various diseases. A relationship between Achilles tendon ruptures and blood type O has been reported, although its pathogenesis was not clear. To the best of our knowledge, there is no published study describing the relationship between blood type and rotator cuff tendon tears. To determine whether patients with rotator cuff tear had a greater prevalence of blood type O than those without rotator cuff tear. A cross-sectional study. Research hospital outpatient evaluation. A total of 316 subjects with shoulder pain were included and divided into "tear" and "no-tear" groups according to ultrasonographic examination. ABO blood group, gender, dominant arm, smoking history, trauma history, and age were compared between the 2 groups and the odds ratios of these factors were evaluated by logistic regression. The tear group (38.6%) had more instances of blood type O than the healthy population (27.2%; P = .002). The adjusted odds ratio for rotator cuff tear for blood type O to non-O was 2.38 (95% confidence interval 1.28-4.42). The odds ratios for rotator cuff tears for smoking, major trauma history, minor trauma history, and age were 2.08, 3.11, 2.29, and 1.06, respectively. Patients with rotator cuff tears were more likely to have blood type O. The odds ratios of factors for rotator cuff tears were high in the following order: major trauma history, blood type O, minor trauma history, and age. Copyright © 2015 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Can artificial tears prevent Acanthamoeba keratitis? An in vitro approach.
Magnet, Angela; Gomes, Thiago Santos; Pardinas, Carmen; Garcia de Blas, Natalia; Sadaba, Cruz; Carrillo, Eugenia; Izquierdo, Fernando; Del Castillo, José Manuel Benítez; Hurtado, Carolina; Del Aguila, Carmen; Fenoy, Soledad
2018-01-22
The use of contact lenses has increased in recent years as has the incidence of Dry Eye Syndrome, partly due to their use. Artificial tears are the most common treatment option. Since these changes can facilitate Acanthamoeba infection, the present study has been designed to evaluate the effect of three artificial tears treatments in the viability of Acanthamoeba genotype T4 trophozoites. Optava Fusion™, Oculotect®, and Artelac® Splash were selected due to their formulation. Viability was assessed using two staining methods, Trypan Blue stain and CTC stain at different time intervals (2, 4, 6, 8 and 24 h). Trypan Blue viability was obtained by manual count with light microscopy while the CTC stain was determined using flow cytometry. Trypan Blue staining results demonstrated a decrease in viability for Optava Fusion™ and Artelac® Splash during the first 4 h of incubation. After, this effect seems to lose strength. In the case of Oculotect®, complete cell death was observed after 2 h. Using flow cytometry analysis, Optava Fusion™ and Oculotect® exhibited the same effect observed with Trypan Blue staining. However, Artelac® Splash revealed decreasing cell respiratory activity after four hours, with no damage to the cell membrane. The present study uses, for the first time, CTC stain analyzed by flow cytometry to establish Acanthamoeba viability demonstrating its usefulness and complementarity with the traditional stain, Trypan Blue. Artelac® Splash, with no preservatives, and Optava Fusion TM, with Purite®, have not shown any useful amoebicidal activity. On the contrary, promising results presented by Ocultect®, with BAK, open up a new possibility for Acanthamoeba keratitis prophylaxis and treatment although in vivo studies should be carried out.
Comparison between single-row and double-row rotator cuff repair: a biomechanical study.
Milano, Giuseppe; Grasso, Andrea; Zarelli, Donatella; Deriu, Laura; Cillo, Mario; Fabbriciani, Carlo
2008-01-01
The aim of this study was to compare the mechanical behavior under cyclic loading test of single-row and double-row rotator cuff repair with suture anchors in an ex-vivo animal model. For the present study, 50 fresh porcine shoulders were used. On each shoulder, a crescent-shaped full-thickness tear of the infraspinatus was performed. Width of the tendon tear was 2 cm. The lesion was repaired using metal suture anchors. Shoulders were divided in four groups, according the type of repair: single-row tension-free repair (Group 1); single-row tension repair (Group 2); double-row tension-free repair (Group 3); double-row tension repair (Group 4); and a control group. Specimens were subjected to a cyclic loading test. Number of cycles at 5 mm of elongation and at failure, and total elongation were calculated. Single-row tension repair showed significantly poorest results for all the variables considered, when compared with the other groups. Regarding the mean number of cycles at 5 mm of elongation and at failure, there was a nonsignificant difference between Groups 3 and 4, and both of them were significantly greater than Group 1. For mean total elongation, the difference between Groups 1, 3, and 4 was not significant, but all of them were significantly lower than the control group. A single-row repair is particularly weak when performed under tension. Double-row repair is significantly more resistant to cyclic displacement than single-row repair in both tension-free and tension repair. Double-row repair technique can be primarily considered for large, unstable rotator cuff tears to improve mechanical strength of primary fixation of tendons to bone.
Tan, Martin; Lam, Patrick H; Le, Brian T N; Murrell, George A C
2016-01-01
Patients with rotator cuff tears often recall a specific initiating event (traumatic), whereas many cannot (nontraumatic). It is unclear how important a history of trauma is to the outcomes of rotator cuff repair. This question was addressed in a study cohort of 1300 consecutive patients who completed a preoperative questionnaire regarding their shoulder injury and had a systematic evaluation of shoulder range of motion and strength, a primary arthroscopic rotator cuff repair performed by a single surgeon, an ultrasound scan, and the same subjective and objective measurements made of their shoulder 6 months after surgery. Post hoc, this cohort was separated into 2 groups: those who reported no history of trauma on presentation (n = 489) and those with a history of traumatic injury (n = 811). The retear rate in the group with no history of trauma was 12%, whereas that of the group with a history of trauma was 14% (P = .36). Those patients with a history of shoulder trauma who waited longer than 24 months had higher retear rates (20%) than those who had their surgery earlier (13%) (P = .040). Recollection of a traumatic initiating event had little effect on the outcome of arthroscopic rotator cuff repair. Duration of symptoms was important in predicting retears if patients recalled a specific initiating event but not in patients who did not recall any specific initiating event. Patients with a history of trauma should be encouraged to have their rotator cuff tear repaired within 2 years. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Krischak, Gert; Gebhard, Florian; Reichel, Heiko; Friemert, Benedikt; Schneider, Florian; Fisser, Christoph; Kaluscha, Rainer; Kraus, Michael
2013-09-01
This pilot study evaluates the outcome after occupational therapy, compared to home-based exercises in the conservative treatment of patients with full thickness rotator cuff tears. Forty-three adult subjects (range, 18-75 years), who had a full thickness rupture of the rotator cuff which was verified by magnetic imaging tomography, with clinical signs of a chronic rotator cuff impingement, and who were available for follow-up, were randomized to occupational therapy or to independent home-based exercises using a booklet. After drop-out, 38 patients were available for full examination at follow-up. Before therapy and after 2 months of conservative treatment, pain intensity, the Constant-Murley score, isokinetic strength testing in abduction and external rotation, functional limitation, clinical shoulder tests and health-related quality of life (EQ-5D) were evaluated. Two-thirds of the patients improved in clinical shoulder tests, regardless of the therapy group. There were no significant differences between the groups with reference to pain, range of motion, maximum peak force (abduction, external rotation), the Constant-Murley score, and the EQ-5D index. The only significant difference observed was the improvement in the self-assessed health- related quality of life (EQ-5D VAS) favoring home-based exercises. Home-based exercise, on the basis of an illustrated booklet with exercises twice a day, supplies comparable results to formal occupational therapy in the conservative treatment of rotator cuff tears. The results of this pilot study suggest some potential advantages related to psychological benefits using home-based treatment. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
49 CFR 173.340 - Tear gas devices.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 2 2010-10-01 2010-10-01 false Tear gas devices. 173.340 Section 173.340... SHIPMENTS AND PACKAGINGS Gases; Preparation and Packaging § 173.340 Tear gas devices. (a) Packagings for tear gas devices must be approved prior to initial transportation by the Associate Administrator. (b...
Svitova, Tatyana F; Lin, Meng C
2016-07-01
This review summarizes the current state of knowledge regarding interfacial properties of very complex biological colloids, specifically, human meibum and tear lipids, and their interactions with proteins similar to the proteins found in aqueous part of human tears. Tear lipids spread as thin films over the surface of tear-film aqueous and play crucial roles in tear-film stability and overall ocular-surface health. The vast majority of papers published to date report interfacial properties of meibum-lipid monolayers spread on various aqueous sub-phases, often containing model proteins, in Langmuir trough. However, it is well established that natural human ocular tear lipids exist as multilayered films with a thickness between 30 and 100nm, that is very much disparate from 1 to 2nm thick meibum monolayers. We employed sessile-bubble tensiometry to study the dynamic interfacial and rheological properties of reconstituted multilayered human tear-lipid films. Small amounts (0.5-1μg) of human tear lipids were deposited on an air-bubble surface to produce tear-lipid films in thickness range 30-100nm corresponding to ocular lipid films. Thus, we were able to overcome major Langmuir-trough method limitations because ocular tear lipids can be safely harvested only in minute, sub-milligram quantities, insufficient for Langmuir through studies. Sessile-bubble method is demonstrated to be a versatile tool for assessing conventional synthetic surfactants adsorption/desorption dynamics at an air-aqueous solution interface. (Svitova T., Weatherbee M., Radke C.J. Dynamics of surfactant sorption at the air/water interface: continuous-flow tensiometry. J. Colloid Interf. Sci. 2003;261:1170-179). The augmented flow-sessile-bubble setup, with step-strain relaxation module for dynamic interfacial rheological properties and high-precision syringe pump to generate larger and slow interfacial area expansions-contractions, was developed and employed in our studies. We established that this method is uniquely suitable for examination of multilayered lipid-film interfacial properties. Recently it was compellingly proven that chemical composition of human tear lipids extracted from whole tears is substantially different from that of meibum lipids. To be exact, healthy human tear lipids contain 8-16% of polar lipids, similar to lung lipids, and they are mostly double-tailed phospholipids, with C16 and longer alkyl chains. Rationally, one would assume that the results obtained for meibum lipids, devoid of surface-active components such as phospholipids, and, above all, in a form of monolayers, are not pertinent or useful for elucidating behavior and stability of an averaged 60-nm thick ocular tear-lipid films in vivo. The advantage of sessile-bubble technique, specifically, using a small amount of lipids required to attain multilayered films, unlocks the prospect of evaluating and comparing the interfacial properties of human tear lipids collected from a single individual, typically 100-150μg. This is in sharp contrast with several milligrams of lipids that would be required to build equally thick films for Langmuir-trough experiments. The results of our studies provided in-depth understanding of the mechanisms responsible for properties and stability of human tear-lipid films in vivo. Here we summarize recent publications and our latest findings regarding human tear-lipid interfacial properties, their chemical composition, and their interaction with model proteins mimicking the proteins found in human tear-aqueous phase. Published by Elsevier B.V.
Tear clearance implications for ocular surface health.
de Paiva, Cintia Sade; Pflugfelder, Stephen C
2004-03-01
Tear clearance/turnover provides a global assessment of the function of the lacrimal functional unit and of tear exchange on the ocular surface. It is an indirect measure of dry eye induced inflammation on the ocular surface. It shows better correlation with the severity of ocular irritation symptoms and corneal epithelial disease in dry eye than the Schirmer 1 test. Delayed tear clearance may prove to be the best measure for identifying patients with tear film disorders who may respond to anti-inflammatory therapy.
MR imaging of the traumatic triangular fibrocartilaginous complex tear
Griffith, James F.; Fung, Cindy S. Y.; Lee, Ryan K. L.; Tong, Cina S. L.; Wong, Clara W. Y.; Tse, Wing Lim; Ho, Pak Cheong
2017-01-01
Triangular fibrocartilage complex is a major stabilizer of the distal radioulnar joint (DRUJ). However, triangular fibrocartilage complex (TFCC) tear is difficult to be diagnosed on MRI for its intrinsic small and thin structure with complex anatomy. The purpose of this article is to review the anatomy of TFCC, state of art MRI imaging technique, normal appearance and features of tear on MRI according to the Palmar’s classification. Atypical tear and limitations of MRI in diagnosis of TFCC tear are also discussed. PMID:28932701
Hot Tearing in Aluminium — Copper Alloys
NASA Astrophysics Data System (ADS)
Viano, David; StJohn, David; Grandfield, John; Cáceres, Carlos
For many aluminium alloys, hot tearing susceptibility follows a lambda curve relationship when hot tearing severity is plotted as a function of solute content. In the past, there has been some difficulty quantifying hot tearing. Traditional methods rely upon measuring electrical resistivity or the number and/or length of cracks in tests such as the ring test. In this experimental program, a hot tear test rig was used to investigate a series of binary Al-Cu alloys. This device measures the load imposed on the mushy zone during solidification. Hot tearing susceptibility was quantified in two ways. The first method involved measuring the load at the solidus temperature (548°C). The second method was to radiograph the hot spot and measure the image density of the cracks. Both methods had advantages and disadvantages. It was found that the results from the hot tear rig correlates with other published data using different experimental methods.
Whittaker, Alexandra L; Williams, David L
2015-01-01
Rabbits are a common animal model in eye research and in safety testing of novel chemical agents. In addition, ocular disease is a routine presentation in clinical practice. However, few studies have quantitatively examined lacrimation kinetics in this species. This study used a noninvasive method of tear measurement (the Schirmer tear test, STT) to quantify values for basal and reflex tearing and to determine the kinetic nature of tear production in 76 New Zealand white rabbits. We obtained a value of 7.58 ± 2.3 mm/min for the standard 1-min STT. Calculated values for mean residual tear volume and reflex tear flow were 1.95 µL and 0.035 µL/s, respectively. In addition, this study provides preliminary evidence for an interaction effect between eyes given that higher STT values were obtained from the second eye tested. PMID:26632789
Tear and decohesion of bovine pericardial tissue.
Tobaruela, Almudena; Elices, Manuel; Bourges, Jean Yves; Rojo, Francisco Javier; Atienza, José Miguel; Guinea, Gustavo
2016-10-01
The aim of this study was to evaluate quantitatively the fracture-by tear and delamination-of bovine pericardium tissues which are usually employed for the manufacture of bioprosthetic valves. A large number of samples (77) were tested in root-to-apex and circumferential directions, according to a standardised tear test (ASTM D 1938). Before performing the tear test, some samples were subjected to 1000 cycles of fatigue to a maximum stress of 3MPa. Fracture toughness of tearing and delamination were computed by following a simple fracture model. The study showed significantly lower values of delamination toughness compared with tear delamination. Moreover, tear forces were different in each test direction, revealing a clear orthotropic behaviour. All these results, as well as the testing procedure, could be of value for future research in the physiological function of pericardium tissues and clinical applications. Copyright © 2016 Elsevier Ltd. All rights reserved.
Topical anaesthetic and tear film stability.
Mengher, L S; Pandher, K S; Bron, A J
1986-02-01
The effect of unpreserved topical anaesthetic on tear film stability (0.4% oxybuprocaine hydrochloride) was investigated in a double masked randomised study in 12 healthy volunteers, using a noninvasive tear film break up technique (NIBUT). It was found that the topical anaesthetic did not reduce the pre-corneal tear film stability, contrary to the electron microscopic evidence.
78 FR 27020 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-09
... circumferential tear strap, the ``Z'' stiffeners at the dome cap, and existing repairs [retained actions from AD... Inspection Under the Tear Strap This paragraph restates the one-time inspection under the tear strap required... under the outer circumferential tear strap, or do a one-time HFEC inspection for cracks from the forward...
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 11 2010-04-01 2010-04-01 true Exhaustion, wear and tear, obsolescence... Rules of General Application § 1.1016-3 Exhaustion, wear and tear, obsolescence, amortization, and... be decreased for exhaustion, wear and tear, obsolescence, amortization, and depletion by the greater...
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 11 2010-04-01 2010-04-01 true Exhaustion, wear and tear, obsolescence...) INCOME TAXES Basis Rules of General Application § 1.1016-4 Exhaustion, wear and tear, obsolescence... be made for exhaustion, wear and tear, obsolescence, amortization, and depletion to the extent...
Superior labrum anterior to posterior tears and glenohumeral instability.
Virk, Mandeep S; Arciero, Robert A
2013-01-01
Cadaver experiments and clinical studies suggest that the superior labrum-biceps complex plays a role in glenohumeral stability. Superior labrum anterior to posterior (SLAP) tears can be present in acute and recurrent glenohumeral dislocations and contribute to glenohumeral instability. Isolated SLAP tears can cause instability, especially in throwing athletes. Diagnosing a SLAP tear on the basis of the clinical examination alone is difficult because of nonspecific history and physical examination findings and the presence of coexisting intra-articular lesions. Magnetic resonance arthrography is the imaging study of choice for diagnosing SLAP tears; however, arthroscopy remains the gold standard for diagnosis. Arthroscopy is the preferred technique for the repair of a type II SLAP tear and its variant types (V through X) in acute glenohumeral dislocations and instability in younger populations. Clinical outcome studies report a low recurrence of glenohumeral instability after the arthroscopic repair of a SLAP tear in addition to a Bankart repair. Long-term follow-up studies and further advances in arthroscopic fixation techniques will allow a better understanding and improvement in outcomes in patients with SLAP tears associated with glenohumeral instability.
Gračanin, Asmir; van Assen, Marcel A L M; Omrčen, Višnja; Koraj, Ivana; Vingerhoets, Ad J J M
2017-01-01
Gelstein et al. reported the results of three experiments suggesting a dampening influence of inhalation of female emotional tears on males' arousal and perception of female sexual attractiveness, specifically in non-sexual situations. This prompted the hypothesis that crying exerts its influence on others not only via the auditory and visual mode but also via chemosignals. In three studies, we attempted to replicate and extend Gelstein et al.'s findings by including an additional condition with irritant tears, by using pictures of sexually attractive women, and by testing related hypotheses on the pro-social effects of exposure to tears. All three studies, separately or combined in a meta-analysis, failed to replicate the original inhibitory effects of tears. In addition, sniffing tears did not affect measures of connectedness, aggression and pro-social behaviour. It is concluded that the effects of female tears on male arousal and perception of female sexual attractiveness, if any, are very weak at best. Rather, it seems that crying exerts its strong inter-personal effects through the visual and auditory sensory channels.
Rothermich, Marcus A; Cohen, Jared A; Wright, Rick
2016-04-01
Meniscal tears can be incidentally encountered at the time of anterior cruciate ligament (ACL) reconstruction. In these cases, the surgeon has several treatment options that include benign neglect, debridement, trephination, and repair. The authors performed a systematic review of the literature studying the various treatment options for meniscal tears discovered at the time of ACL reconstruction. This systematic review included eight articles that had relevant data regarding benign neglect compared with debridement, trephination, or repair of incidentally encountered meniscal tears. Combined data from these studies resulted in a total of 646 meniscal tears treated with benign neglect with follow-up information available. Importantly, there were differences in reoperation rates between medial and lateral meniscal tears left in situ. However, stable medial and lateral meniscal tears treated with benign neglect did not have different subjective or objective outcomes than those treated with surgical intervention. This systematic review concludes that when stable meniscal tears are encountered at the time of arthroscopic ACL reconstruction, benign neglect can be used for a successful outcome. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Tear gas: an epidemiological and mechanistic reassessment
Rothenberg, Craig; Achanta, Satyanarayana; Svendsen, Erik R.
2016-01-01
Deployments of tear gas and pepper spray have rapidly increased worldwide. Large amounts of tear gas have been used in densely populated cities, including Cairo, Istanbul, Rio de Janeiro, Manama (Bahrain), and Hong Kong. In the United States, tear gas was used extensively during recent riots in Ferguson, Missouri. Whereas tear gas deployment systems have rapidly improved—with aerial drone systems tested and requested by law enforcement—epidemiological and mechanistic research have lagged behind and have received little attention. Case studies and recent epidemiological studies revealed that tear gas agents can cause lung, cutaneous, and ocular injuries, with individuals affected by chronic morbidities at high risk for complications. Mechanistic studies identified the ion channels TRPV1 and TRPA1 as targets of capsaicin in pepper spray, and of the tear gas agents chloroacetophenone, CS, and CR. TRPV1 and TRPA1 localize to pain‐sensing peripheral sensory neurons and have been linked to acute and chronic pain, cough, asthma, lung injury, dermatitis, itch, and neurodegeneration. In animal models, transient receptor potential inhibitors show promising effects as potential countermeasures against tear gas injuries. On the basis of the available data, a reassessment of the health risks of tear gas exposures in the civilian population is advised, and development of new countermeasures is proposed. PMID:27391380
Examination of in vivo tear film stability after eye blink and eye drying
NASA Astrophysics Data System (ADS)
Szczesna, Dorota H.; Kulas, Zbigniew; Kasprzak, Henryk T.; Stenevi, Ulf
2007-07-01
The purpose of this study is to investigate the kinetics of precorneal tear film stabilization process after eye blink and the process of creating the break-up of the tear film layer. The tear film of patients were examined in vivo by used the lateral shearing interferometer. The information about the distribution and stability of the tear film over the cornea is carried by the wave front reflected from the surface of tears and coded in interference fringes. Smooth and regular fringes indicate the smooth surface of tears over the cornea. Immediately after eye blink the interference fringes are observed on background of bright and dark areas. The contrast of this structure fades with time slowly and after 1-3 sec the background of interference fringes becomes uniform. The vertical orientation and instability of this structure suggests connection with eyelid movement and the spread of tears. If the eye is kept open for a long time, bright lines appear in the background of fringes after a dozen seconds. The slowly appearing structure might signify the tear film break-up. In case of eyes after a LASIK surgery the shape of the background structure has different nature and might be stable in time suggesting the stability of the corneal surface irregularities.
Tear Film Dynamics: the roles of complex structure and rheology
NASA Astrophysics Data System (ADS)
Dey, Mohar; Feng, James; Vivek, Atul S.; Dixit, Harish N.; Richhariya, Ashutosh
2016-11-01
Ocular surface infections such as microbial and fungal keratitis are among leading causes of blindness in the world. A thorough understanding of the pre-corneal tear film dynamics is essential to comprehend the role of various tear layer components in the escalation of such ocular infections. The pre-corneal tear film comprises of three layers of complex fluids, viz. the innermost mucin layer, a hydrophilic protective cover over the sensitive corneal epithelium, the intermediate aqueous layer that forms the bulk of the tear film and is often embedded with large number of bio-polymers either in the form of soluble mucins or pathogens, and finally the outermost lipid layer that stabilizes the film by decreasing the air/tear film interfacial tension. We have developed a comprehensive mathematical model to describe such a film by incorporating the effects of the non-uniform mucin distribution along with the complex rheology of the aqueous layer with/without pathogens, Marangoni effects from the lipid layer and the slip effects at the base of the tear film. A detailed linear stability analysis and a fully non-linear solution determine the break up time (BUT) of such a tear film. We also probe the role of the various components of the pre-corneal tear film in the dynamics of rupture.
Fracture under combined modes in 4340 steel
NASA Technical Reports Server (NTRS)
Shah, R. C.
1974-01-01
An experimental investigation was conducted to study the interaction of combined modes of loading on crack instability in the presence of the opening and sliding modes of stress intensity factors, the opening and tearing modes of stress intensity factors, and all three modes of stress intensity factors. Through-cracked and surface-cracked flat and round specimens, and round notched bar specimens fabricated from high strength 4340 steel were used for the investigation. The results are evaluated to determine fracture criteria under the combined modes of stress intensity factors for the 4340 steel. These results are compared with the results of other investigators obtained for different materials.
Schmidt, Christopher C; Jarrett, Claudius D; Brown, Brandon T
2013-04-01
Distal biceps tendon ruptures continue to be an important injury seen and treated by upper extremity surgeons. Since the mid-1980s, the emphasis has been placed on techniques that limit complications or improve initial tendon-to-bone fixation strength. Recently, basic science research has expanded the knowledge base regarding the biceps tendon structure, footprint anatomy, and biomechanics. Clinical data have further delineated the results of conservative and surgical management of both partial and complete tears in acute or chronic states. The current literature on the distal biceps tendon is described in detail. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Symptoms, visual function, and mucin expression of eyes with tear film instability.
Shimazaki-Den, Seika; Dogru, Murat; Higa, Kazunari; Shimazaki, Jun
2013-09-01
We examined symptoms, tear stability, visual function, and conjunctival cytology in eyes with an unstable tear film (UTF), expressed as a short tear film breakup time without epithelial damage or low tear secretion, and compared the results with those from eyes with aqueous deficiency (AD) associated with epithelial damage, and healthy eyes. We divided the patients with ocular discomfort into 2 groups according to the breakup time, Schirmer value, and epithelial staining score: UTF group (≤5 seconds, >5 mm, and <3 points; 21 eyes of 21 patients) and AD group (≤5 seconds, ≤5 mm, and ≥3 points; 21 eyes of 21 patients). We examined all patients and 17 healthy subjects for symptoms, tear functions, tear film stability by tear film lipid layer interferometry and tear film analysis system, and functional visual acuity. Conjunctival impression cytology was performed to investigate changes in goblet cell density, squamous metaplasia, and messenger RNA expression of MUC5AC and MUC16. The symptom scores, tear film analysis system index, and functional visual acuity testing were significantly worse in the UTF and AD groups compared with those in the control group (P < 0.05). The messenger RNA expression levels of MUC5AC and MUC16 were significantly lower in UTF and AD eyes compared with those in the control eyes (P < 0.0001). An UTF itself can cause dry eye symptoms and visual disturbance comparable with those of AD dry eyes.
Ibrahim, Osama M A; Dogru, Murat; Ward, Samantha K; Matsumoto, Yukihiro; Wakamatsu, Tais Hitomi; Ishida, Katsushi; Tsuyama, Atsushi; Kojima, Takashi; Shimazaki, Jun; Tsubota, Kazuo
2011-04-06
To evaluate the specificity and sensitivity of strip meniscometry (SM) testing in conjunction with tear function tests in the diagnosis of dry eye (DE) disease and to investigate the effect of SM on reflex tearing. One hundred seven left eyes of 107 patients with definite DE disease according to the Japanese DE diagnostic criteria and 68 left eyes of 68 age- and sex-matched control subjects were studied. Tear meniscus height (TMH) measurements, fluorescein tear film break-up time (FTBUT), fluorescein (F) and rose bengal (RB) staining, and Schirmer's test-1 (ST) were also performed. The assessment of reflex tearing before and after SM application was assessed with a graticule scale at the slit lamp and by optical coherence tomography. The sensitivity and specificity of SM alone and in combination with tear function tests were also sought. The SM scores, TMH measurements, FTBUTs, and STs were significantly lower in dry eye patients than in the controls (P < 0.001). The RB and F staining scores were significantly higher in the dry eye group than in the control group (P < 0.001). The meniscometry strips did not induce significant changes in relation to reflex tearing. SM had an acceptable sensitivity and specificity. SM is a swift, noninvasive, promising method of assessing tear meniscus volume. The combined SM and FTBUT examination appears to be a sensitive approach to the assessment of dry eye disease.
Tong, Louis; Zhou, Xi Yuan; Jylha, Antti; Aapola, Ulla; Liu, Dan Ning; Koh, Siew Kwan; Tian, Dechao; Quah, Joanne; Uusitalo, Hannu; Beuerman, Roger W; Zhou, Lei
2015-02-06
Tear proteins are intimately related to the pathophysiology of the ocular surface. Many recent studies have demonstrated that the tear is an accessible fluid for studying eye diseases and biomarker discovery. This study describes a high resolution multiple reaction monitoring (HR-MRM) approach for developing assays for quantification of biologically important tear proteins. Human tear samples were collected from 1000 subjects with no eye complaints (411 male, 589 female, average age: 55.5±14.5years) after obtaining informed consent. Tear samples were collected using Schirmer's strips and pooled into a single global control sample. Quantification of proteins was carried out by selecting "signature" peptides derived by trypsin digestion. A 1-h nanoLC-MS/MS run was used to quantify the tear proteins in HR-MRM mode. Good reproducibility of signal intensity (using peak areas) was demonstrated for all 47 HR-MRM assays with an average coefficient of variation (CV%) of 4.82% (range: 1.52-10.30%). All assays showed consistent retention time with a CV of less than 0.80% (average: 0.57%). HR-MRM absolute quantitation of eight tear proteins was demonstrated using stable isotope-labeled peptides. In this study, we demonstrated for the first time the technique to quantify 47 human tear proteins in HR-MRM mode using approximately 1μl of human tear sample. These multiplexed HR-MRM-based assays show great promise of further development for biomarker validation in human tear samples. Both discovery-based and targeted quantitative proteomics can be achieved in a single quadrupole time-of-flight mass spectrometer platform (TripleTOF 5600 system). Copyright © 2015 Elsevier B.V. All rights reserved.
Wurtzel, Caroline Nw; Gumucio, Jonathan P; Grekin, Jeremy A; Khouri, Roger K; Russell, Alan J; Bedi, Asheesh; Mendias, Christopher L
2017-11-01
Anterior cruciate ligament (ACL) tears are among the most frequent knee injuries in sports medicine, with tear rates in the US up to 250,000 per year. Many patients who suffer from ACL tears have persistent atrophy and weakness even after considerable rehabilitation. Myostatin is a cytokine that directly induces muscle atrophy, and previous studies rodent models and patients have demonstrated an upregulation of myostatin after ACL tear. Using a preclinical rat model, our objective was to determine if the use of a bioneutralizing antibody against myostatin could prevent muscle atrophy and weakness after ACL tear. Rats underwent a surgically induced ACL tear and were treated with either a bioneutralizing antibody against myostatin (10B3, GlaxoSmithKline) or a sham antibody (E1-82.15, GlaxoSmithKline). Muscles were harvested at either 7 or 21 days after induction of a tear to measure changes in contractile function, fiber size, and genes involved in muscle atrophy and hypertrophy. These time points were selected to evaluate early and later changes in muscle structure and function. Compared to the sham antibody group, 7 days after ACL tear, myostatin inhibition reduced the expression of proteolytic genes and induced the expression of hypertrophy genes. These early changes in gene expression lead to a 22% increase in muscle fiber cross-sectional area and a 10% improvement in maximum isometric force production that were observed 21 days after ACL tear. Overall, myostatin inhibition lead to several favorable, although modest, changes in molecular biomarkers of muscle regeneration and reduced muscle atrophy and weakness following ACL tear. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2499-2505, 2017. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Umans, Hilary; Srinivasan, Ramya; Elsinger, Elisabeth; Wilde, Gregory E
2014-10-01
To identify the variety of second and third intermetatarsal space (IS) lesions that may coexist with and without adjacent metatarsophalangeal joint (MTP) plantar plate (PP) tears. One hundred forefoot MRIs in 96 patients with metatarsalgia obtained between 30 September 2011 and 21 July 2012 using 1.5- or 3-T MRI were retrospectively reviewed in consensus by two MSK radiologists and one podiatrist (DPM). MRI was evaluated for second and third MTP PP tear and the presence/nature of second and third IS lesions. Second and third IS neuromas were measured in transverse (trans) dimension. A total of 40 PP tears were identified: 36 at the second and 4 at the third MTP. Second MTP PP tear was identified in 33% of females and 40.5% of males. In the 63 female feet there were 21 second MTP PP tears, all of which also had second IS lesions: pericapsular fibrosis (16), bursitis (4), and ganglion (1). In the 37 male feet there were 15 second MTP PP tears, 14 of which had second IS lesions: pericapsular fibrosis (8), bursitis (5), and ganglion (1). There was no definite second IS neuroma adjacent to any second MTP PP tear. In females without PP tear, there were 24 second (3 mm trans average) and 43 third IS neuromas (4.1 mm trans average). In males without PP tear, there were 9 second (3.4 mm trans average) and 16 third IS neuromas (4.1 mm trans average). MTP PP tears occurred in 40% of our cases, 90% of which occurred at the second MTP. Almost all coexisted with non-neuromatous second IS lesions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sabau, Adrian S.; Mirmiran, Seyed; Glaspie, Christopher
Here, the hot-tearing resistance of multicomponent Al-Cu alloys during permanent mold casting was investigated using a constrained permanent mold in which the load and temperature were measured. The nominal Cu composition was varied from 5 to 8 wt pct. Casting experiments were conducted without adding any grain-refining inoculants. The following variables, which were obtained from the measured load data during casting, were considered to assess the hot-tearing resistance of the Al-Cu multicomponent alloys: “V”-like signature in the load rate variation, load at solidus point, and load rate average over the freezing range. In addition, a hot-tearing criterion based on themore » variation of the fraction of solid in the late stages of solidification was used. It was found that all criteria considered can accurately predict the alloys with the lowest and highest hot-tear resistance, respectively. It was found that the rate of measured load during casting could be used to indicate substantial hot tearing. However, the load rate variation could not be used to detect when small hot tears were present. Among all the criteria considered, the load at the solidus point shows an excellent agreement with experimentally observed hot-tearing resistance for all but one alloy. The poorly resistant hot-tearing alloys exhibited mainly coarse columnar grains while the most hot-tearing resistant alloys exhibited a much more refined grain microstructure. This is the first study in which good hot-tear resistance is demonstrated for multicomponent Al-Cu alloys with nominal Cu content greater than 7 wt pct.« less
Dogru, Murat; Ward, Samantha K; Wakamatsu, Tais; Ibrahim, Osama; Schnider, Cristina; Kojima, Takashi; Matsumoto, Yukihiro; Ogawa, Junko; Shimazaki, Jun; Tsubota, Kazuo
2011-04-01
To prospectively investigate the effects of 2 week senofilcon A contact lens (CL) daily wear on the functional visual acuity (VA), ocular surface and tear film. Seventeen right eyes of 17 senofilcon A CL wearers without any ocular or systemic diseases were examined before and 2 weeks after lens wear. Visual acuity measurements, tear evaporation rate, ELISA for tear cytokines, strip meniscometry, tear lipid layer interferometry, tear film break-up time (BUT), in vivo confocal microscopy, corneal sensitivity, ocular surface vital staining, Schirmer I test and brush cytology for MUC5AC mRNA expression were performed before and after CL wear. The best corrected Landolt VA, functional VA parameters, the mean lipid layer interferometry grades, tear evaporation rates, Schirmer test values, vital staining scores and in vivo confocal microscopy parameters did not show any significant differences after 2 weeks of CL wear. The tear film BUT showed a significant decrease together with a significant down regulation of MUC5 AC mRNA expression after CL wear. A statistically significant elevation in the mean tear interleukin (IL)-6 concentration was also observed after 2 weeks of CL wear. Two week senofilcon A daily CL wear seems to be associated with tear instability, a decrease in MUC5AC expression, and elevation of IL-6 in tears without significant alterations in epithelial damage scores or in the morphology or density of in vivo keratoconjunctival cells and nerves. Alterations associated with long term wear and patients with dry eye disease need to be studied in future trials. Copyright © 2010 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Formation of Hot Tear Under Controlled Solidification Conditions
NASA Astrophysics Data System (ADS)
Subroto, Tungky; Miroux, Alexis; Bouffier, Lionel; Josserond, Charles; Salvo, Luc; Suéry, Michel; Eskin, Dmitry G.; Katgerman, Laurens
2014-06-01
Aluminum alloy 7050 is known for its superior mechanical properties, and thus finds its application in aerospace industry. Vertical direct-chill (DC) casting process is typically employed for producing such an alloy. Despite its advantages, AA7050 is considered as a "hard-to-cast" alloy because of its propensity to cold cracking. This type of cracks occurs catastrophically and is difficult to predict. Previous research suggested that such a crack could be initiated by undeveloped hot tears (microscopic hot tear) formed during the DC casting process if they reach a certain critical size. However, validation of such a hypothesis has not been done yet. Therefore, a method to produce a hot tear with a controlled size is needed as part of the verification studies. In the current study, we demonstrate a method that has a potential to control the size of the created hot tear in a small-scale solidification process. We found that by changing two variables, cooling rate and displacement compensation rate, the size of the hot tear during solidification can be modified in a controlled way. An X-ray microtomography characterization technique is utilized to quantify the created hot tear. We suggest that feeding and strain rate during DC casting are more important compared with the exerted force on the sample for the formation of a hot tear. In addition, we show that there are four different domains of hot-tear development in the explored experimental window—compression, microscopic hot tear, macroscopic hot tear, and failure. The samples produced in the current study will be used for subsequent experiments that simulate cold-cracking conditions to confirm the earlier proposed model.
Lee, Kwan Bok; Koh, Kyung Min; Kwon, Young A; Song, Sang Wroul; Kim, Byoung Yeop; Chung, Jae Lim
2017-08-01
To evaluate changes in the tear meniscus area and tear meniscus height over time in patients with dry eye syndrome, using anterior segment spectral-domain optical coherence tomography after the instillation of 3% diquafosol ophthalmic solution. Sixty eyes from 30 patients with mild to moderate dry eye syndrome were included. Tear meniscus images acquired by anterior segment spectral-domain optical coherence tomography were analyzed using National Institutes of Health's image-analysis software (ImageJ 1.44p). Tear meniscus area and tear meniscus height were measured at baseline, 5 minutes, 10 minutes, and 30 minutes after instillation of a drop of diquafosol in one eye and normal saline in the other eye. Changes in ocular surface disease index score, tear film break-up time, corneal staining score by Oxford schema, and meibomian expressibility were also evaluated at baseline, and after 1 week and 1 month of a diquafosol daily regimen. Sixty eyes from 30 subjects (mean age, 29.3 years; 8 men and 22 women) were included. In eyes receiving diquafosol, tear volume was increased at 5 and 10 minutes compared with baseline. It was also higher than saline instilled eyes at 5, 10, and 30 minutes. Changes in tear volume with respect to baseline were not statistically different after the use of diquafosol for 1 month. Ocular surface disease index score, tear film break-up time, and Oxford cornea stain score were significantly improved after 1 week and 1 month of daily diquafosol instillation, but meibomian expressibility did not change. Topical diquafosol ophthalmic solution effectively increased tear volume for up to 30 minutes, compared to normal saline in patients with dry eye syndrome. © 2017 The Korean Ophthalmological Society
Non-invasive pre-lens tear film assessment with high-speed videokeratoscopy.
Llorens-Quintana, Clara; Mousavi, Maryam; Szczesna-Iskander, Dorota; Iskander, D Robert
2018-02-01
To evaluate the effect of two types of daily contact lenses (delefilcon A and omafilcon A) on the tear film and establish whether it is dependent on pre-corneal tear film characteristics using a new method to analyse high-speed videokeratoscopy recordings, as well as to determine the sensitivity of the method in differentiating between contact lens materials on eye. High-speed videokeratoscopy recordings were analysed using a custom made automated algorithm based on a fractal dimension approach that provides a set of parameters directly related to tear film stability. Fifty-four subjects participated in the study. Baseline measurements, in suppressed and natural blinking conditions, were taken before subjects were fitted with two different daily contact lenses and after four hours of contact lens wear. The method for analysing the stability of the tear film provides alternative parameters to the non-invasive break up time to assess the quality of the pre-corneal and pre-lens tear film. Both contact lenses significantly decreased the quality of the tear film in suppressed and natural blinking conditions (p<0.001). The utilised method was able to distinguish between contact lens materials on eye in suppressed blinking conditions. The pre-corneal tear film characteristics were not correlated with the decrease in pre-lens tear film quality. High-speed videokeratoscopy equipped with an automated method to analyse the dynamics of the tear film is able to distinguish between contact lens materials in vivo. Incorporating the assessment of pre-lens tear film to the clinical practice could aid improving contact lens fitting and understand contact lens comfort. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Antimicrobial compounds in tears.
McDermott, Alison M
2013-12-01
The tear film coats the cornea and conjunctiva and serves several important functions. It provides lubrication, prevents drying of the ocular surface epithelia, helps provide a smooth surface for refracting light, supplies oxygen and is an important component of the innate defense system of the eye providing protection against a range of potential pathogens. This review describes both classic antimicrobial compounds found in tears such as lysozyme and some more recently identified such as members of the cationic antimicrobial peptide family and surfactant protein-D as well as potential new candidate molecules that may contribute to antimicrobial protection. As is readily evident from the literature review herein, tears, like all mucosal fluids, contain a plethora of molecules with known antimicrobial effects. That all of these are active in vivo is debatable as many are present in low concentrations, may be influenced by other tear components such as the ionic environment, and antimicrobial action may be only one of several activities ascribed to the molecule. However, there are many studies showing synergistic/additive interactions between several of the tear antimicrobials and it is highly likely that cooperativity between molecules is the primary way tears are able to afford significant antimicrobial protection to the ocular surface in vivo. In addition to effects on pathogen growth and survival some tear components prevent epithelial cell invasion and promote the epithelial expression of innate defense molecules. Given the protective role of tears a number of scenarios can be envisaged that may affect the amount and/or activity of tear antimicrobials and hence compromise tear immunity. Two such situations, dry eye disease and contact lens wear, are discussed here. Copyright © 2013 Elsevier Ltd. All rights reserved.
Incomplete response to artificial tears is associated with features of neuropathic ocular pain.
Galor, Anat; Batawi, Hatim; Felix, Elizabeth R; Margolis, Todd P; Sarantopoulos, Konstantinos D; Martin, Eden R; Levitt, Roy C
2016-06-01
Artificial tears are first-line therapy for patients with dry eye symptoms. It is not known, however, which patient factors associate with a positive response to therapy. The purpose of this study was to evaluate whether certain ocular and systemic findings are associated with a differential subjective response to artificial tears. Cross-sectional study of 118 individuals reporting artificial tears use (hypromellose 0.4%) to treat dry eye-associated ocular pain. An evaluation was performed to assess dry eye symptoms (via the dry eye questionnaire 5 and ocular surface disease index), ocular and systemic (non-ocular) pain complaints and ocular signs (tear osmolarity, tear breakup time, corneal staining, Schirmer testing with anaesthesia, and eyelid and meibomian gland assessment). The main outcome measures were factors associated with differential subjective response to artificial tears. By self-report, 23 patients reported no improvement, 73 partial improvement and 22 complete improvement in ocular pain with artificial tears. Patients who reported no or partial improvement in pain with artificial tears reported higher levels of hot-burning ocular pain and sensitivity to wind compared with those with complete improvement. Patients were also asked to rate the intensity of systemic pain elsewhere in the body (other than the eye). Patients who reported no or incomplete improvement with artificial tears had higher systemic pain scores compared with those with complete improvement. Both ocular and systemic (non-ocular) pain complaints are associated with a differential subjective response to artificial tears. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Sabau, Adrian S.; Mirmiran, Seyed; Glaspie, Christopher; ...
2018-02-16
Here, the hot-tearing resistance of multicomponent Al-Cu alloys during permanent mold casting was investigated using a constrained permanent mold in which the load and temperature were measured. The nominal Cu composition was varied from 5 to 8 wt pct. Casting experiments were conducted without adding any grain-refining inoculants. The following variables, which were obtained from the measured load data during casting, were considered to assess the hot-tearing resistance of the Al-Cu multicomponent alloys: “V”-like signature in the load rate variation, load at solidus point, and load rate average over the freezing range. In addition, a hot-tearing criterion based on themore » variation of the fraction of solid in the late stages of solidification was used. It was found that all criteria considered can accurately predict the alloys with the lowest and highest hot-tear resistance, respectively. It was found that the rate of measured load during casting could be used to indicate substantial hot tearing. However, the load rate variation could not be used to detect when small hot tears were present. Among all the criteria considered, the load at the solidus point shows an excellent agreement with experimentally observed hot-tearing resistance for all but one alloy. The poorly resistant hot-tearing alloys exhibited mainly coarse columnar grains while the most hot-tearing resistant alloys exhibited a much more refined grain microstructure. This is the first study in which good hot-tear resistance is demonstrated for multicomponent Al-Cu alloys with nominal Cu content greater than 7 wt pct.« less
Gwak, Heui-Chul; Kim, Chang-Wan; Kim, Jung-Han; Choo, Hye-Jeung; Sagong, Seung-Yeob; Shin, John
2015-05-01
The purpose of this study was to evaluate the extension of delamination and the cuff integrity after arthroscopic repair of delaminated rotator cuff tears. Sixty-five patients with delaminated rotator cuff tears were retrospectively reviewed. The delaminated tears were divided into full-thickness delaminated tears and partial-thickness delaminated tears. To evaluate the medial extension, we calculated the coronal size of the delaminated portion. To evaluate the posterior extension, we checked the tendon involved. Cuff integrity was evaluated by computed tomography arthrography. The mean medial extension in the full-thickness and partial-thickness delaminated tears was 18.1 ± 6.0 mm and 22.7 ± 6.3 mm, respectively (P = .0084). The posterior extension into the supraspinatus and the infraspinatus was 36.9% and 32.3%, respectively, in the full-thickness delaminated tears, and it was 27.7% and 3.1%, respectively, in the partial-thickness delaminated tears (P = .0043). With regard to cuff integrity, 35 cases of anatomic healing, 10 cases of partial healing defects, and 17 cases of retear were detected. Among the patients with retear and partial healing of the defect, all the partially healed defects showed delamination. Three retear patients showed delamination, and 14 retear patients did not show delamination; the difference was statistically significant (P = .0001). The full-thickness delaminated tears showed less medial extension and more posterior extension than the partial-thickness delaminated tears. Delamination did not develop in retear patients, but delamination was common in the patients with partially healed defects. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Sebbag, Lionel; Showman, Lucas; McDowell, Emily M; Perera, Ann; Mochel, Jonathan P
2018-04-30
Compare the precision of doxycycline quantification in tear fluid collected with either Schirmer strips or polyvinyl acetal (PVA) sponges following oral drug administration. Three dogs and 3 cats were administered doxycycline orally at a dose of 4.2-5 mg/kg every 12 h for 6 consecutive days. At day 5 and 6, blood and tear fluid were sampled to capture doxycycline trough and maximal concentrations. Tear fluid was collected 3 times (spaced 10 min apart) at each session with the absorbent material placed in the lower conjunctival fornix until the 20-mm mark was reached (Schirmer strip, one eye) or for 1 min (PVA sponge, other eye). Tear extraction was performed with either centrifugation or elution in methanol. Doxycycline concentrations were measured with liquid chromatography-mass spectrometry. Low (100 ng/mL) and high (1,000 ng/mL) tear concentrations measured in vivo were spiked into each absorbent material in vitro to evaluate percentage drug recovery. After oral administration of doxycycline, the drug reached the tear compartment at concentrations of 45.1-900.7 ng/mL in cats and 45.4-632.0 ng/mL in dogs, representing a tear-to-serum ratio of 12% and 16%, respectively. Doxycycline tear concentrations were significantly more precise when tear collection was performed with Schirmer strips rather than PVA sponges (P = 0.007), but were not correlated with tear flow rate. In vitro doxycycline recovery was poor to moderate (<75%). Schirmer strips represent a good option for lacrimal doxycycline quantification, although the collection and subsequent extraction have to be optimized to improve drug recovery.
Photon correlation spectroscopy applied to tear analysis.
Picarazzi, S; Lecchi, M; Pastori, V; D'Arienzo, M; Scotti, R; Tavazzi, S
2017-09-01
This study aims to deepen the knowledge on tear film properties by the development of a protocol for analyses of Photon Correlation Spectroscopy (PCS) on human tears and by the comparison between PCS results obtained on tears of contact lens wearers and non-wearers. Tears (5μL) were collected by a glass capillary. The analyses provide the hydrodynamic diameter of tear components by analyzing intensity fluctuations in time of scattered light. PCS appears a promising technique for studying tear features and for shedding light on specific eye conditions, such as on the clinical effects of CL wear. In fact, statistical difference (p<0.001) was found between the measured mean hydrodynamic diameter of tear components of wearers and non-wearers, the resulting value significantly higher for CL wearers. The scenario does not substantially change after (25±5)min from the CL removal. The difference is attributed to changes in the interactions between tear constituents due to CL wear. In order to get deeper insights on the influence of CL wear on aggregation and structure of tear components, a preliminary Electron Spin Resonance (ESR) investigation was performed, monitoring Fe 3+ species. ESR spectra on tears of both CL wearers and non-wearers showed the presence of intense signals, probably associated to iron (III) centers in proteins such as lactoferrin, and a weaker resonance attributable to Fe 3+ species interacting with S-S bridges of lysozyme. Differences in ESR spectra between CL wearers and non-wearers were detected and tentatively ascribed to changes in coordination or in local environment of Fe 3+ centers connected to aggregation phenomena induced by CL wear, which promote their interaction with other neighboring iron species. Copyright © 2017. Published by Elsevier B.V.
Effect of Ambient Temperature on the Human Tear Film.
Abusharha, Ali A; Pearce, E Ian; Fagehi, Raied
2016-09-01
During everyday life, the tear film is exposed to a wide range of ambient temperatures. This study aims to investigate the effect of ambient temperature on tear film physiology. A controlled environment chamber was used to create different ambient temperatures (5, 10, 15, 20, and 25°C) at a constant relative humidity of 40%. Subjects attended for two separate visits and were exposed to 25, 20, and 15°C at one visit and to 10 and 5°C at the other visit. The subjects were exposed to each room temperature for 10 min before investigating tear film parameters. The order of the visits was random. Tear physiology parameters assessed were tear evaporation rate, noninvasive tear break-up time (NITBUT), lipid layer thickness (LLT), and ocular surface temperature (OST). Each parameter was assessed under each condition. A threefold increase in tear evaporation rate was observed as ambient temperature increased to 25°C (P=0.00). The mean evaporation rate increased from 0.056 μL/min at 5°C to 0.17 μL/min at 25°C. The mean NITBUT increased from 7.31 sec at 5°C to 12.35 sec at 25°C (P=0.01). A significant change in LLT was also observed (P=0.00), LLT median ranged between 20 and 40 nm at 5 and 10°C and increased to 40 and 90 nm at 15, 20, and 25°C. Mean reduction of 4°C OST was observed as ambient temperature decreased from 25 to 5°C. Ambient temperature has a considerable effect on human tear film characteristics. Tear evaporation rate, tear LLT, tear stability, and OST were considerably affected by ambient temperature. Chronic exposure to low ambient temperature would likely result in symptoms of dry eye and ultimately ocular surface disorders.
Association Between Contact Lens Discomfort and Pre-lens Tear Film Kinetics.
Guillon, Michel; Dumbleton, Kathryn A; Theodoratos, Panagiotis; Wong, Stephanie; Patel, Kishan; Banks, Gaidig; Patel, Trisha
2016-08-01
The relationship between contact lens wettability and comfort has been extensively evaluated; however, a direct correlation between the characteristics of the pre-lens tear film and the symptoms associated with contact lens discomfort has yet to be established. In addition, there is relatively limited knowledge relating to the entire tear film kinetics during the inter-blink period in contact lens wearers. The purpose of this analysis was to identify the characteristics of the pre-lens tear film kinetics that may be associated with the symptoms of contact lens discomfort. The study population comprised 202 soft (hydrogel and silicone hydrogel) contact lens wearers attending pre-screening visits at the OTG-i research clinic. All participants completed the Ocular Surface Disease Index (OSDI) questionnaire and the tear film was quantified via post hoc, masked analysis of high definition digital Tearscope videos recorded at the visit. The tear film kinetics of the least symptomatic wearers (OSDI lowest quintile scores, n = 45) were compared to the tear film kinetics of the most symptomatic wearers (OSDI highest quintile scores, n = 43). The hypothesis tested was that the tear film kinetics of asymptomatic wearers were better than tear film kinetics of symptomatic wearers. The distribution of lens types worn was as follows: Daily Disposable 46.5%, 1-Month Replacement 39.6%, and 2-Week Replacement 13.6%. 48.2% of lenses were silicone hydrogel and 51.8% hydrogel. Symptomatic wearers had a shorter break-up time (4.7 s vs. 6.0 s; p = 0.003), lesser surface coverage by the tear film during the interblink period (95.1% vs. 98.5%; p < 0.001) and greater surface exposure at the time of the blink (9.4% vs. 3.9%; p = 0.001). The current study demonstrated that the tear film kinetics of asymptomatic and symptomatic contact lens wearers were different, the findings supporting the hypothesis of poorer tear film kinetics for symptomatic than asymptomatic wearers in a general contact lens wearing population.
Tung, Glenn A; Hou, David D
2003-02-01
The purpose of our study was to investigate the relationship between tears of the posterior labrocapsular complex and glenohumeral alignment on MR arthrography and the presence and extent of posterior labrocapsular tears in patients with posterior instability. Posterior labrocapsular tears identified on 24 MR arthrograms and surgically confirmed were evaluated for length of tear and labrocapsular avulsion. These examinations and a comparison cohort of 70 normal MR arthrograms with normal findings were also evaluated for humeral head position relative to the glenoid fossa. Medical records were reviewed for clinical diagnosis of posterior instability and history of shoulder trauma. The position of the humeral head relative to the glenoid was significantly more posterior in patients with posterior labral tear than in patients with a normal posterior labrum (4.9 mm versus 0.7 mm; p < 0.0001). The mean length (+/- SD) of posterior labral tear was 15.9 +/- 1.7 mm, and a direct correlation was found between tear length and posterior humeral translation (r = -0.65; p = 0.002). Posterior labral tears were significantly longer (18.6 vs 13.1 mm; p = 0.04), and posterior humeral translation was greater (6.4 vs 3.4 mm; p = 0.006) in patients with labrocapsular avulsion than in those without avulsion. Twelve (50%) of the patients with posterior labrocapsular tear had posterior instability, and 10 (83%) had a history of macrotrauma. On MR arthrography, the mean posterior humeral translation was greater (6.2 mm +/- 0.08; p = 0.019), posterior labral tears were longer (19.4 mm +/- 1.7; p = 0.0008), and labrocapsular avulsion was more common (83%; p = 0.0001) in patients with posterior instability than in patients who had a posterior labral tear but a clinically stable shoulder. Clinical posterior instability is associated with excessive posterior humeral translation, long posterior labral tears, and posterior labrocapsular avulsion.
Shi, Jing-lin; Miao, Wan-hong
2012-09-01
With the understanding of the immune inflammatory response in the pathogenesis of dry eyes, and the limitations of widely used artificial tears and numerous pharmaceuticals and methods to promote tear secretion, clinicians pay more attention to the therapies that can promote tear secretion actively. Acupuncture treatment for dry eye may meet this requirement. To observe the clinical efficacy of acupuncture treatment on dry eye and the effects on duration, and to examine the mechanisms of acupuncture in treating patients with dye eyes. The study was performed at Department of Ophthalmology, Shuguang Hospital, Shanghai University of Traditional Chinese Medicine from August 2010 to May 2011. Patients with the primary diagnosis of dry eye were enrolled. Sixty-five patients were randomly divided into treatment group and control group, and were given 3 weeks of acupuncture treatment or artificial tear therapy respectively. The enzyme-linked immunosorbent assay was used to detect the lactoferrin content of the tears before and after treatment. In order to evaluate the efficacy of the treatment methods, the Schirmer I test and break-up time were also measured. Compared with before treatment, the lactoferrin content in the tears of patients in the treatment group increased, break-up time was prolonged and the result of the Schirmer I test showed improvement after 3 weeks of treatment. The indexes mentioned above did not change in the control group after treatment. There were no significant differences in tear lactoferrin and Schirmer I test between one week after treatment and after 3-week treatment in the treatment group, but break-up time was significantly shortened. The result of Schirmer I test in the treatment group was significantly higher than that in the control group one week after treatment. Acupuncture can increase tear lactoferrin level, extend tear film break-up time and promote tear secretion in patients with dry eye in a time-limited trial. With the end of treatment, the effect decreased.
[Alterations in tears aqueous layer during cytostatics treatment].
Wojciechowska, Katarzyna; Wieckowska-Szakiel, Marzena; Rózalska, Barbara; Jurowski, Piotr
2013-01-01
The aim of the study was to evaluate tears secretion, pH and lysozyme activity in tears aqueous layer during chemotherapy in lung, breast and bowel cancer. 36 patients were enrolled to the study. Depending on the type of cancer and type of chemotherapy patients were divided into three groups. Group I (12 patients) diagnosed with non-small-cell lung cancer treated with PE schema (cisplatin, etoposide), Group II (12 patients) with breast cancer treated with FAC schema (fluorouracil, doxorubicin, cyclophosphamide), Group III (12 patients) with bowel cancer treated with FU/LV schema (fluorouracil, leucovorin). In all the patients: Schirmer's I test, pH measurements and lysozyme test were performed. Patients were examined before chemotherapy, after 2nd, 4th, 6th cycle. In group I and II lowering of tears secretion (p < 0.001) was revealed. In group III there was higher tears secretion (p < 0.001). PH was lowered after 2nd chemotherapy course in group I and II. In further treatment pH value were in the same lower level as after the second course. In group III there was higher pH--more alkaline (p < 0.001) after 2nd cycle of treatment and it was on the same level to the end of the examination process. Lowering of lysozyme activity in the tears film in all groups (p < 0.001) was established. The higher alterations of the lysozyme activity were observed in group treated with FAC schema. Cytostatic treatment has major influence on tears aqueous layer causing alterations of tears secretions. PH alterations depending on type of chemotherapy was observed. Lowering of lysozyme activity in tears was observed. All the deteriorations aggravate with duration of chemotherapy. Alterations of tears film parameters during chemotherapy may influence upon eye surface homeostasis and infectious complication. tears aqueous layer, Schirmer's test, lysozyme activity, tears pH.
Magnetic resonance imaging evidence of meniscal extrusion in medial meniscus posterior root tear.
Choi, Chul-Jun; Choi, Yun-Jin; Lee, Jae-Jeong; Choi, Chong-Hyuk
2010-12-01
The purpose of this study was to evaluate the relation between meniscal extrusion on magnetic resonance imaging (MRI) and tearing of the posterior root of the medial meniscus, as well as to understand the relation between meniscal extrusion and chondral lesions. From January 2007 to December 2008, 387 consecutive cases of medial meniscal tears were treated arthroscopically. Of these cases, 248 (64.1%) with MRI were reviewed. Arthroscopic findings were reviewed for the type of tear and medial compartment cartilage lesion. Root tear was defined as a radial tear in the posterior horn of the medial meniscus near the tibial spine (i.e., within 5 mm of the root attachment). An MRI scan of the knee was used to evaluate the presence and extent of meniscal extrusion. Meniscal extrusion of 3 mm or greater was considered pathologic. Arthroscopic findings were compared with respect to the extent of meniscal extrusion. There were 98 male patients and 150 female patients. The mean age was 53.5 years (range, 15 to 81 years). The results showed 127 cases (51.2%) in which the medial meniscus had meniscal extrusion of 3 mm or greater. Posterior root tears were found in 66 (26.6%) of the 248 knees. The mean meniscal extrusion in patients with root tear was 3.8 ± 1.4 mm, whereas the mean extrusion of those who had no root tear was 2.7 ± 1.3 mm. We found an association between pathologic meniscal extrusion and root tear (P < .001). Meniscal extrusion showed a low positive predictive value (39%) and specificity (58%) with regard to the meniscal root tear. Meniscal extrusion was also significantly correlated with severity of chondral lesions (P < .001). Considerable extrusion (≥3 mm) can be associated with tearing of the medial meniscus root and chondral lesion of the medial femoral condyle. Level IV, therapeutic case series. Copyright © 2010 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Clinical and surgical correlation of hip MR arthrographic findings in adolescents.
Jawahar, Anugayathri; Vade, Aruna; Lomasney, Laurie; Okur, Gokcan; Evans, Douglas; Subbaiah, Perla
2016-06-01
The purpose of this study was to analyze the utility of MRA-H in adolescents by comparing the results of imaging with surgical findings and/or clinical outcome. After obtaining appropriate IRB approval, the Radiologic Information System database was queried for all patients 13-18 years of age who underwent MRA-H from 2004 through 2013. The electronic medical record was reviewed for clinical history, clinical examination findings, and operative notes. MRA-H images were reviewed for soft tissue abnormalities (labral tear, paralabral ganglion, articular cartilage loss, synovitis, ligament tears) and bony abnormalities (cam-type femoroacetabular impingement (FAI), pincer-type FAI, hip dysplasia). MRA-H findings were correlated with surgical findings and with clinical outcomes. Twenty-six patients with labral tears by MRA-H were included in study and grouped as follows: Group I) patients who underwent surgical management (n=10); group II) patients managed non-surgically (medication, intra-articular injection, physical therapy) (n=9); group III) patients lost to follow up after being advised to have surgery (n=7). With regard to presenting symptomatology, 87.5% of patients with labral tear had groin pain. Of those patients who were diagnosed with a labral tear, 52% were categorized as idiopathic labral tears, 26% as secondary tears (secondary to abnormal bony morphology), and 22% as traumatic labral tears. The labral tears were found to be anterior in 61% and posterior in 22%. Associated articular cartilage lesions were found in 29% of patients. In group I (surgical patients), MRA-H labral findings were confirmed at surgery in 9/10. Seventy percent of labral tears in our study had some form of abnormal bony morphology. Nine of the 12 patients with bone abnormalities were derived from group I patients. Six out of 7 patients with cam-type FAI had a labral tear. Labral tears diagnosed by MRA-H in the adolescent population correlated well with clinical examination and surgical findings. Also, MRA-H contributed by defining bony morphology that was directly applied to surgical management. Non-surgical management of labral tears diagnosed on MRA-H had a generally favorable outcome. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
LaPrade, Christopher M; Jansson, Kyle S; Dornan, Grant; Smith, Sean D; Wijdicks, Coen A; LaPrade, Robert F
2014-03-19
An avulsion of the posterior root attachment of the lateral meniscus or a radial tear close to the root attachment can lead to degenerative knee arthritis. Although the biomechanical effects of comparable injuries involving the medial meniscus have been studied, we are aware of no such study involving the lateral meniscus. We hypothesized that in situ pull-out suture repair of lateral meniscus root avulsions and of complete radial tears 3 and 6 mm from the root attachment would increase the contact area and decrease mean and peak tibiofemoral contact pressures, at all knee flexion angles, relative to the corresponding avulsion or tear condition. Eight human cadaveric knees underwent biomechanical testing. Eight lateral meniscus conditions (intact, footprint tear, root avulsion, root avulsion repair, radial tears at 3 and 6 mm from the posterior root, and repairs of the 3 and 6-mm tears) were tested at five different flexion angles (0°, 30°, 45°, 60°, and 90°) under a compressive 1000-N load. Avulsion of the posterior root of the lateral meniscus or an adjacent radial tear resulted in significantly decreased contact area and increased mean and peak contact pressures in the lateral compartment, relative to the intact condition, in all cases except the root avulsion condition at 0° of flexion. In situ pull-out suture repair of the root avulsion or radial tear significantly reduced mean contact pressures, relative to the corresponding avulsion or tear condition, when the results for each condition were pooled across all flexion angles. Posterior horn root avulsions and radial tears adjacent to the root attachment of the lateral meniscus significantly increased contact pressures in the lateral compartment. In situ pull-out suture repairs of these tears significantly improved lateral compartment joint contact pressures. In situ repair may be an effective treatment to improve tibiofemoral contact profiles after an avulsion of the posterior root of the lateral meniscus or a complete radial tear adjacent to the root. In situ repairs should be further investigated clinically as an alternative to partial lateral meniscectomy.
Proteases, proteolysis and inflammatory molecules in the tears of people with keratoconus.
Balasubramanian, Sivaraman Arumugam; Mohan, Sujatha; Pye, David Cecil; Willcox, Mark Duncan Perry
2012-06-01
To investigate the expression of proteases, proteolytic activity and cytokines in the tear film of people with keratoconus. Basal tears from people with keratoconus, from individuals who had undergone corneal collagen cross-linking for the treatment of keratoconus, and from normal controls were collected using a capillary tube. Corneal curvature of each subject was mapped. The total protein in tears was estimated. Levels and activity of proteases in the tears were analysed using specific antibody arrays and activity assays. The total tear protein level was significantly reduced in keratoconus (4.1 ± 0.9 mg/ml) compared with normals (6.7 ± 1.4 mg/ml) (p < 0.0001) or subjects who had undergone corneal collagen cross-linking (5.7 ± 2.3 mg/ml) (p < 0.005). Significantly (p < 0.05) increased tear expression of matrix metalloproteinases (MMP) -1, -3, -7, -13, interleukins (IL) -4, -5, -6, -8 and tumour necrosis factor (TNF) -α, -β were evident in keratoconus. Tear IL-6 was the only cytokine significantly (p < 0.05) increased in tears of keratoconus subjects compared with the collagen cross-linked group. No significant difference in tear proteases were observed between the normal and the cross-linked groups, although the expression of TNF-α was significantly (p < 0.05) increased in the cross-linked group compared with the controls. Elevated gelatinolytic (87.5 ± 33.6 versus 45.8 ± 24.6 FIU, p < 0.0001) and collagenolytic (6.1 ± 3.2 versus 3.6 ± 2.0 FIU, p < 0.05) activities were observed in tears from keratoconus compared with normal subjects. The activity of tear gelatinases (69.6 ± 22.2 FIU) and collagenases (5.7 ± 3.3 FIU) in the collagen cross-linked group was not significantly different compared with either keratoconus or normals. Tears of people with keratoconus had 1.9 times higher levels of proteolytic activity and over expression of several MMPs and cytokines compared with tears from controls. Further investigations are required to study the possible implications of these changes and whether they can be used to monitor disease progression or determine the success of corneal collagen cross-linking. © 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.
Chaharbakhshi, Edwin O; Perets, Itay; Ashberg, Lyall; Mu, Brian; Lenkeit, Christopher; Domb, Benjamin G
2017-09-01
Arthroscopic surgery in borderline dysplastic hips remains controversial, but the role of the ligamentum teres (LT) has not been studied in this setting. Borderline dysplastic patients with LT tears have worse short-term outcomes than those without LT tears. Cohort study; Level of evidence, 3. Data were prospectively collected on patients who underwent arthroscopic surgery between February 2008 and April 2014. The inclusion criteria were borderline dysplasia (lateral center-edge angle [LCEA], 18°-25°) and labral tears; arthroscopic treatments including labral preservation and capsular plication; and preoperative patient-reported outcome scores including the modified Harris Hip Score (mHHS), Non-Arthritic Hip Score (NAHS), Hip Outcome Score-Sport-Specific Subscale, and visual analog scale for pain. Patients were excluded for preoperative Tönnis osteoarthritis grade >0, workers' compensation claims, previous ipsilateral hip surgery and conditions, or frank dysplasia (LCEA <18°). Patients with LT tears were pair-matched to patients without tears for sex, age at surgery ±10 years, body mass index (<30 kg/m 2 vs ≥30 kg/m 2 ), labral treatment type, and microfracture. Of 68 eligible patients, 63 (93%) had a minimum 2-year follow-up, and 30 (48%) had LT tears. Twenty patients in each group were pair-matched. The mean follow-up time was 54.3 months (range, 24.2-83.8 months) for the LT tear group and 38.6 months (range, 24.6-70.6 months) for the control group ( P = .002). Ninety percent were female. There were no significant differences regarding demographics or intra-operative procedures. The LT tear group trended toward lower postoperative mHHS ( P = .09) and NAHS ( P = .09) values. Mean satisfaction was 8.1 for the LT tear group and 7.9 for the control group. Preoperative and follow-up scores were not significantly different between the groups. The LT tear group had 5 revisions, with 1 revision in the control group. Three patients (15%) in the LT tear group underwent total hip arthroplasty (THA); no patients in the control group required THA. In borderline dysplastic patients undergoing hip arthroscopic surgery with labral treatment and capsular plication, LT tears may indicate advanced instability and portend slightly inferior outcomes when compared with a match-controlled group. Borderline dysplastic patients with LT tears may have increased propensities toward revision arthroscopic surgery and conversion to THA. LT tears in these patients may warrant consideration for additional procedures including periacetabular osteotomy and LT reconstruction.
Maier, Dirk; Jaeger, Martin; Reising, Kilian; Feucht, Matthias J; Südkamp, Norbert P; Izadpanah, Kaywan
2016-09-06
Horizontal instability impairs clinical outcome following acute acromioclavicular joint (ACJ) reconstruction and may be caused by insufficient healing of the superior acromioclavicular ligament complex (ACLC). However, characteristics of acute ACLC injuries are poorly understood so far. Purposes of this study were to identify different ACLC tear types, assess type-specific prevalence and determine influencing cofactors. This prospective, cross-sectional study comprised 65 patients with acute-traumatic Rockwood-5 (n = 57) and Rockwood-4 (n = 8) injuries treated operatively by means of mini-open ACJ reduction and hook plate stabilization. Mean age at surgery was 38.2 years (range, 19-57 years). Standardized pre- and intraoperative evaluation included assessment of ACLC tear patterns and cofactors related to the articular disc, the deltoid-trapezoidal (DT) fascia and bony ACJ morphology. Articular disc size was quantified as 0 = absent, 1 = remnant, 2 = meniscoid and 3 = complete. All patients showed complete ruptures of the superior ACLC, which could be assigned to four different tear patterns. Clavicular-sided (AC-1) tears were observed in 46/65 (70.8 %), oblique (AC-2) tears in 12/65 (18.5 %), midportion (AC-3) tears in 3/65 (4.6 %) and acromial-sided (AC-4) tears in 4/65 (6.1 %) of cases. Articular disc size manifestation was significantly (P < .001) more pronounced in patients with AC-1 tears (1.89 ± 0.57) compared to patients with AC-2 tears (0.67 ± 0.89). Other cofactors did not influence ACLC tear patterns. ACLC dislocation with incarceration caused mechanical impediment to anatomical ACJ reduction in 14/65 (21.5 %) of cases including all Rockwood-4 dislocations. Avulsion "in continuity" was a consistent mode of failure of the DT fascia. Type-specific operative strategies enabled anatomical ACLC repair of all observed tear types. Acute ACLC injuries follow distinct tear patterns. There exist clavicular-sided (AC-1), oblique (AC-2), midportion (AC-3) and acromial-sided (AC-4) tears. Articular disc size was a determinant factor of ACLC tear morphology. Mini-open surgery was required in Rockwood-4 and a relevant proportion of Rockwood-5 dislocations to achieve both anatomical ACLC and ACJ reduction. Type-specific operative repair of acute ACLC tears might promote biological healing and lower rates of horizontal ACJ instability following acute ACJ reconstruction.
77 FR 66757 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-07
... tear straps and in the skin locations common to the tear straps. Additionally, we received a report of... cracking in the lap joint fastener row between tear straps of the crown lap and do a detailed inspection of...-53A1255, Revision 2, dated August 7, 2012. (j) Optional Inspections for Tear Strap Locations Only As an...
A very rare case of bloody tears with enigmatic epistaxis and haematuria.
Ho, Jason Z S; de Silva, Julian; Olver, Jane
2011-03-01
Bloody tears are a rare symptom that can be caused by local or systemic pathology. We describe a very rare case of bloody tears that resulted from hyperthyroidism. A 15-year-old female patient presented with a 6-month history of bloody tears and epistaxis. Examination excluded local ocular and nasal pathology, including neoplasm and coagulopathy. Systemic investigations identified elevated thyroid function and following treatment her symptoms resolved. We discuss the mechanism by which hyperthyroidism may induce haemostatic dysfunction. We present the first case of bloody tears secondary to thyroid dysfunction.
The Art of Dressing Selection: A Consensus Statement on Skin Tears and Best Practice.
LeBlanc, Kimberly; Baranoski, Sharon; Christensen, Dawn; Langemo, Diane; Edwards, Karen; Holloway, Samantha; Gloeckner, Mary; Williams, Ann; Campbell, Karen; Alam, Tarik; Woo, Kevin Y
2016-01-01
To provide information about product selection for the management of skin tears. This continuing education activity is intended for physicians and nurses with an interest in skin and wound care. After participating in this educational activity, the participant should be better able to:1. Explain skin tear (ST) risk factors and assessment guidelines.2. Identify best practice treatments for STs, including the appropriate dressings for each ST type. To aid healthcare professionals in product selection specific for skin tears, the International Skin Tear Advisory Panel conducted a systematic literature review and 3-phase Delphi consensus with a panel of international reviewers to provide the best available evidence for product selection related to the treatment of skin tears.
Interactions of toroidally coupled tearing modes in the KSTAR tokamak
NASA Astrophysics Data System (ADS)
Kim, Gnan; Yun, Gunsu S.; Woo, Minho; Park, Hyeon K.; KSTAR Team2, the
2018-03-01
The evolutions of toroidally coupled radially-distant and radially-adjacent tearing modes are visualized in 2D in detail on the Korea superconducting tokamak for advanced research. The coupled tearing modes are in-phase on the out-board mid-plane and become destabilized or compete with each other depending on their spatial separation. When two coupled tearing modes are far apart, both are increasingly destabilized. On the other hand, when they become close to each other, one becomes stabilized while the other becomes destabilized. In such cases, an additional tearing mode is often formed on outer rational flux surface and the three tearing modes compete. The competitions suggest that spatial overlap (merging) of coupled magnetic islands is difficult.
Intra-articular pathology associated with isolated posterior cruciate ligament injury on MRI.
Ringler, Michael D; Shotts, Ezekiel E; Collins, Mark S; Howe, B Matthew
2016-12-01
Unlike with anterior cruciate ligament injury, little is known about the prevalence of intra-articular pathology associated with isolated posterior cruciate ligament (PCL) injury in the knee. The objectives of this study were to characterize and identify the frequency of meniscal tears and osteochondral injuries in these patients, and to see if management might be affected. Altogether, 48 knee MRI exams with isolated PCL tears were evaluated for the presence of: grade and location of PCL tear, meniscal tear, articular chondral lesion, bone bruise, and fracture. Comparisons between PCL tear grade and location, as well as mechanism of injury when known, with the presence of various intra-articular pathologies, were made using the chi-square or Fisher's exact test as appropriate. In all, 69 % of isolated PCL tears occur in the midsubstance, 27 % proximally. Meniscal tears were seen in 25 % of knees, involving all segments of both menisci, except for the anterior horn medial meniscus. Altogether, 23 % had focal cartilage lesions, usually affecting the central third medial femoral condyle and medial trochlea, while 12.5 % of knees had fractures, and 48 % demonstrated bone bruises, usually involving the central to anterior tibiofemoral joint. The presence of a fracture (p = 0.0123) and proximal location of PCL tear (p = 0.0016) were both associated with the hyperextension mechanism of injury. There were no statistically significant associations between PCL tear grade and presence of intra-articular abnormality. Potentially treatable meniscal tears and osteochondral injuries are relatively prevalent, and demonstrable on MRI in patients with isolated acute PCL injury of the knee.
Hirata, Harumitsu; Mizerska, Kamila; Marfurt, Carl F.; Rosenblatt, Mark I.
2015-01-01
Purpose In an effort to elucidate possible neural mechanisms underlying diminished tearing in dry eye disease, this study sought to determine if hyperosmolar tears, a ubiquitous sign of dry eye disease, produce functional changes in corneal nerve responses to drying of the cornea and if these changes correlate with alterations in corneal nerve morphology. Methods In vivo extracellular electrophysiological recordings were performed in rat trigeminal ganglion neurons that innervated the cornea before, and up to 3 hours after, the ocular application of continuous hyperosmolar tears or artificial tears. In corollary experiments, immunohistochemical staining was performed to compare corneal nerve morphology in control and in eyes treated with hyperosmolar solutions. Results Our previous studies identified a population of corneal afferents, dry-sensitive neurons that are strongly excited by corneal dessication (“dry response”), a response thought to trigger the lacrimation reflex. In the present study, we found that the dry responses of corneal dry-sensitive neurons were depressed or even completely abolished by hyperosmolar tears in a time- (30 minutes to 3 hours) and dose (450- to 1000-mOsm solutions)-dependent manner. Furthermore, eyes treated with hyperosmolar tears for 3 hours contained large numbers of morphologically abnormal (granular, fragmented, or prominently beaded) subbasal nerves that appeared to be undergoing degeneration. Conclusions These results demonstrate that tear hyperosmolarity, considered to be a “core” mechanism of dry eye disease, significantly decreases physiological sensitivity and morphologic integrity of the corneal nerves important in tear production. These alterations might contribute to the diminished tearing seen clinically in dry eye patients. PMID:26720465
Advanced glycation end product (AGE) modified proteins in tears of diabetic patients.
Zhao, Zhenjun; Liu, Jingfang; Shi, Bingyin; He, Shuixiang; Yao, Xiaoli; Willcox, Mark D P
2010-08-11
High glucose level in diabetic patients may lead to advanced glycation end product (AGE) modified proteins. This study investigated AGE modified proteins in tears and compared their levels in diabetic patients (DM) with non-diabetic controls (CTL). Basal tears were collected from DM with (DR) or without (DNR) retinopathy and CTL. Total AGE modified proteins were detected quantitatively by a dot immunobinding assay. The AGE modified proteins were separated in 1D- and 2D-SDS gels and detected by western-blotting. The individual AGE modified proteins were also compared between groups using densitometry. Compared with the CTL group, tear concentrations of AGE modified proteins were significantly elevated in DR and DNR groups. The concentration of AGE modified proteins in diabetic tears were positively correlated with AGE modified hemoglobin (HbA1c) and postprandial blood glucose level (PBG). Western blotting of AGE modified proteins from 1D-SDS gels showed several bands, the major one at around 60 kDa. The intensities of AGE modified protein bands were higher in DM tears than in CTL tears. Western blotting from 2D-SDS gels showed a strongly stained horizontal strip, which corresponded to the major band in 1D-SDS gels. Most of the other AGE modified protein species were within molecular weight of 30-60 kDa, PI 5.2-7.0. Densitometry analysis demonstrated several AGE modified proteins were elevated in DR or DNR tears. Total and some individual AGE modified proteins were elevated in DM tears. AGE modified proteins in tears may be used as biomarkers to diagnose diabetes and/or diabetic retinopathy.
Laurie, Diane E; Splan, Rebecca K; Green, Kari; Still, Katherine M; McKown, Robert L; Laurie, Gordon W
2012-09-12
Lacritin is a human tear glycoprotein that promotes basal tear protein secretion in cultured rat lacrimal acinar cells and proliferation of subconfluent human corneal epithelial cells. When topically added to rabbit eyes, lacritin promotes basal tearing. Despite these activities on several species, lacritin's presence in nonprimate tears or other tissues has not been explored. Here we probed for lacritin in normal horse tears. Sequences were collected from the Ensembl genomic alignment of human LACRT gene with high-quality draft horse genome (EquCab2.0) and analyzed. Normal horse tears were collected and assayed by Western blotting, ELISA, and mass spectrometry. Newly generated rabbit antibodies, respectively, against N- and C-terminal regions of human lacritin were employed. Identity was 75% and 45%, respectively, at nucleotide and protein levels. Structural features were conserved, including a C-terminal amphipathic α-helix. Anti-C-terminal antibodies strongly detected a ∼13 kDa band in horse tears that was validated by mass spectrometry. In human tears, the same antibody detected uncleaved lacritin (∼24 kDa) strongly and C-terminal fragments of ∼13 and ∼11 kDa weakly. Anti-N-terminal antibodies were slightly reactive with a ∼24 kDa horse antigen and showed no reaction with the anti-C-terminal-reactive ∼13 kDa species. Similar respective levels of horse C-terminal versus N-terminal immunoreactivity were apparent by ELISA. Lacritin is present in horse tears, largely as a C-terminal fragment homologous to the mitogenic and bactericidal region in human lacritin, suggesting potential benefit in corneal wound repair.
Hirata, Harumitsu; Mizerska, Kamila; Marfurt, Carl F; Rosenblatt, Mark I
2015-12-01
In an effort to elucidate possible neural mechanisms underlying diminished tearing in dry eye disease, this study sought to determine if hyperosmolar tears, a ubiquitous sign of dry eye disease, produce functional changes in corneal nerve responses to drying of the cornea and if these changes correlate with alterations in corneal nerve morphology. In vivo extracellular electrophysiological recordings were performed in rat trigeminal ganglion neurons that innervated the cornea before, and up to 3 hours after, the ocular application of continuous hyperosmolar tears or artificial tears. In corollary experiments, immunohistochemical staining was performed to compare corneal nerve morphology in control and in eyes treated with hyperosmolar solutions. Our previous studies identified a population of corneal afferents, dry-sensitive neurons that are strongly excited by corneal dessication ("dry response"), a response thought to trigger the lacrimation reflex. In the present study, we found that the dry responses of corneal dry-sensitive neurons were depressed or even completely abolished by hyperosmolar tears in a time- (30 minutes to 3 hours) and dose (450- to 1000-mOsm solutions)-dependent manner. Furthermore, eyes treated with hyperosmolar tears for 3 hours contained large numbers of morphologically abnormal (granular, fragmented, or prominently beaded) subbasal nerves that appeared to be undergoing degeneration. These results demonstrate that tear hyperosmolarity, considered to be a "core" mechanism of dry eye disease, significantly decreases physiological sensitivity and morphologic integrity of the corneal nerves important in tear production. These alterations might contribute to the diminished tearing seen clinically in dry eye patients.
Reyes, Bryan A; Hull, Brandon R; Kurth, Alexander B; Kukowski, Nathan R; Mulligan, Edward P; Khazzam, Michael S
2017-11-01
Many patients with rotator cuff tears suffer from nocturnal shoulder pain, resulting in sleep disturbance. To determine whether rotator cuff tear size correlated with sleep disturbance in patients with full-thickness rotator cuff tears. Cross-sectional study; Level of evidence, 3. Patients with a diagnosis of unilateral full-thickness rotator cuff tears (diagnosed via magnetic resonance imaging [MRI]) completed the Pittsburgh Sleep Quality Index (PSQI), a visual analog scale (VAS) quantifying their shoulder pain, and the American Shoulder and Elbow Surgeons (ASES) questionnaire. Shoulder MRI scans were analyzed for anterior-posterior tear size (mm), tendon retraction (mm), Goutallier grade (0-4), number of tendons involved (1-4), muscle atrophy (none, mild, moderate, or severe), and humeral head rise (present or absent). Bivariate correlations were calculated between the MRI characteristics and baseline survey results. A total of 209 patients with unilateral full-thickness rotator cuff tears were included in this study: 112 (54%) female and 97 (46%) male (mean age, 64.1 years). On average, shoulder pain had been present for 24 months. The mean PSQI score was 9.8, and the mean VAS score was 5.0. No significant correlations were found between any of the rotator cuff tear characteristics and sleep quality. Only tendon retraction had a significant correlation with pain. Although rotator cuff tears are frequently associated with nocturnal pain and sleep disruption, this study demonstrated that morphological characteristics of full-thickness rotator cuff tears, such as size and tendon retraction, do not correlate with sleep disturbance and have little to no correlation with pain levels.
A Multicenter Study of the Presentation, Treatment, and Outcomes of Cervical Dural Tears.
O'Neill, Kevin R; Fehlings, Michael G; Mroz, Thomas E; Smith, Zachary A; Hsu, Wellington K; Kanter, Adam S; Steinmetz, Michael P; Arnold, Paul M; Mummaneni, Praveen V; Chou, Dean; Nassr, Ahmad; Qureshi, Sheeraz A; Cho, Samuel K; Baird, Evan O; Smith, Justin S; Shaffrey, Christopher; Tannoury, Chadi A; Tannoury, Tony; Gokaslan, Ziya L; Gum, Jeffrey L; Hart, Robert A; Isaacs, Robert E; Sasso, Rick C; Bumpass, David B; Bydon, Mohamad; Corriveau, Mark; De Giacomo, Anthony F; Derakhshan, Adeeb; Jobse, Bruce C; Lubelski, Daniel; Lee, Sungho; Massicotte, Eric M; Pace, Jonathan R; Smith, Gabriel A; Than, Khoi D; Riew, K Daniel
2017-04-01
Retrospective multicenter case series study. Because cervical dural tears are rare, most surgeons have limited experience with this complication. A multicenter study was performed to better understand the presentation, treatment, and outcomes following cervical dural tears. Multiple surgeons from 23 institutions retrospectively identified 21 rare complications that occurred between 2005 and 2011, including unintentional cervical dural tears. Demographic data and surgical history were obtained. Clinical outcomes following surgery were assessed, and any reoperations were recorded. Neck Disability Index (NDI), modified Japanese Orthopaedic Association (mJOA), Nurick classification (NuC), and Short-Form 36 (SF36) scores were recorded at baseline and final follow-up at certain centers. All data were collected, collated, and analyzed by a private research organization. There were 109 cases of cervical dural tears among 18 463 surgeries performed. In 101 cases (93%) there was no clinical sequelae following successful dural tear repair. There were statistical improvements ( P < .05) in mJOA and NuC scores, but not NDI or SF36 scores. No specific baseline or operative factors were found to be associated with the occurrence of dural tears. In most cases, no further postoperative treatments of the dural tear were required, while there were 13 patients (12%) that required subsequent treatment of cerebrospinal fluid drainage. Analysis of those requiring further treatments did not identify an optimum treatment strategy for cervical dural tears. In this multicenter study, we report our findings on the largest reported series (n = 109) of cervical dural tears. In a vast majority of cases, no subsequent interventions were required and no clinical sequelae were observed.
Kakel, Rafid; Russell, Robert; VanHeerden, Pieter
2010-10-11
Bucket handle tears of both menisci in the setting of acute or chronic anterior cruciate ligament (ACL) tears of the same knee have rarely been reported in the literature. This article presents a case of a bucket handle tear affecting both the medial and lateral menisci in a patient with chronic ACL rupture. Both bucket handle tears were displaced and locked in the intercondylar notch. A new magnetic resonance image (MRI) sign suggested on sagittal view is called the triple PCL sign, comprising the intact posterior cruciate ligament (PCL) and the 2 displaced fragments in the intercondylar notch from the two bucket handle tears. The precise diagnosis of this condition is of obvious importance for optimal operative planning. While finding the displaced fragment from the medial meniscus is expected to cause the double PCL sign, the torn ACL may have made it easier to visualize the bucket handle tear of the lateral meniscus in the same sagittal plane as the PCL. Only 5 other reports mention bimeniscal bucket handle tears of both the medial and lateral menisci in association with an ACL tear. None have shown the suggested triple PCL sign because of lack of overlap between the 2 bucket handle tears in the coronal plane while lying in the intercondylar notch causing them not to fall in the same sagittal plane. Our patient showed some overlap between the 2 meniscal fragments while lying in the notch to create the triple PCL sign on sagittal MRI. Copyright 2010, SLACK Incorporated.
De Smet, Arthur A; Graf, Ben K; del Rio, Alejandro Munoz
2011-02-01
Although patients with parameniscal cysts usually have underlying meniscal tears, we noted that this association was less common with anterior lateral cysts. We wished to determine whether the frequency of a meniscal tear underlying a parameniscal cyst varied with cyst location. We reviewed a database of 7,771 knee MR examinations and identified 134 patients with an MR diagnosis of 138 parameniscal cysts and correlative arthroscopy in 78 patients. We reviewed their medical records and MR studies to determine the location of the cysts and presence of an underlying meniscal tear as determined by MRI or arthroscopy. There were 50 lateral and 88 medial parameniscal cysts. Medial meniscal tears were found underlying a cyst in 96% of arthroscopy patients and 86% of patients who had only MR examinations without a location difference in tears (p = 0.68). Meniscal tears were found on MRI or arthroscopy in all 28 patients with a lateral cyst overlying the body or posterior horn of the lateral meniscus, whereas a tear was found on MRI or arthroscopy in only 14 (64%) of 22 patients with cysts adjacent to or extending to the lateral meniscus anterior horn (p = 0.006). Anterior lateral cysts extended medially either into the root or into Hoffa fat-pad, but the type of extension did not correlate with the presence of an underlying meniscal tear. In contrast to medial parameniscal cysts or cysts at other locations adjacent to the lateral meniscus, anteriorly located lateral parameniscal cysts are less likely to have underlying meniscal tears.
Double row equivalent for rotator cuff repair: A biomechanical analysis of a new technique.
Robinson, Sean; Krigbaum, Henry; Kramer, Jon; Purviance, Connor; Parrish, Robin; Donahue, Joseph
2018-06-01
There are numerous configurations of double row fixation for rotator cuff tears however, there remains to be a consensus on the best method. In this study, we evaluated three different double-row configurations, including a new method. Our primary question is whether the new anchor and technique compares in biomechanical strength to standard double row techniques. Eighteen prepared fresh frozen bovine infraspinatus tendons were randomized to one of three groups including the New Double Row Equivalent, Arthrex Speedbridge and a transosseous equivalent using standard Stabilynx anchors. Biomechanical testing was performed on humeri sawbones and ultimate load, strain, yield strength, contact area, contact pressure, and a survival plots were evaluated. The new double row equivalent method demonstrated increased survival as well as ultimate strength at 415N compared to the remainder testing groups as well as equivalent contact area and pressure to standard double row techniques. This new anchor system and technique demonstrated higher survival rates and loads to failure than standard double row techniques. This data provides us with a new method of rotator cuff fixation which should be further evaluated in the clinical setting. Basic science biomechanical study.
NASA Astrophysics Data System (ADS)
Xue, Xiaodong; Yin, Qing; Jia, Hongbing; Zhang, Xuming; Wen, Yanwei; Ji, Qingmin; Xu, Zhaodong
2017-11-01
Graphene oxide (GO) with various oxidation degrees were prepared through a modified Hummer's method by varying the dosage of oxidizing agent. Styrene-butadiene rubber (SBR)/carboxylated acrylonitrile butadiene rubber (XNBR)/GO nanocomposites were fabricated by aqueous-phase mixing of GO colloidal dispersion with SBR latex and a small loading of XNBR latex, followed by co-coagulation. Effects of GO oxidation degree on the morphology, structure, mechanical and thermal properties of nanocomposites were thoroughly investigated. The results showed that the mechanical strength of nanocomposites were enhanced with the increase of oxidation degree of GO. Especially, when the weight ratio of KMnO4 to graphite was 15/5, the tensile strength, tear strength and thermal conductivity of SBR/XNBR/GO filled with 3 phr (parts per hundred rubber) GO increased by 255.3%, 141.5% and 22.8%, respectively, compared to those of neat SBR/XNBR blend. In addition, the thermal stability and the solvent resistance of the nanocomposites were also improved significantly. This work suggested that GO with higher oxidation degree could effectively improve the properties of SBR/XNBR blend.
On the extraordinary strength of Prince Rupert's drops
NASA Astrophysics Data System (ADS)
Aben, H.; Anton, J.; Öis, M.; Viswanathan, K.; Chandrasekar, S.; Chaudhri, M. M.
2016-12-01
Prince Rupert's drops (PRDs), also known as Batavian tears, have been in existence since the early 17th century. They are made of a silicate glass of a high thermal expansion coefficient and have the shape of a tadpole. Typically, the diameter of the head of a PRD is in the range of 5-15 mm and that of the tail is 0.5 to 3.0 mm. PRDs have exceptional strength properties: the head of a PRD can withstand impact with a small hammer, or compression between tungsten carbide platens to high loads of ˜15 000 N, but the tail can be broken with just finger pressure leading to catastrophic disintegration of the PRD. We show here that the high strength of a PRD comes from large surface compressive stresses in the range of 400-700 MPa, determined using techniques of integrated photoelasticity. The surface compressive stresses can suppress Hertzian cone cracking during impact with a small hammer or compression between platens. Finally, it is argued that when the compressive force on a PRD is very high, plasticity in the PRD occurs, which leads to its eventual destruction with increasing load.
Influence of topical anesthesia on tear dynamics and ocular drug bioavailability in albino rabbits.
Patton, T F; Robinson, J R
1975-02-01
The bioavailability of topically applied ocular drugs is very poor, due largely to drug loss through drainage and tear turnover. The use of high viscosity solutions or solid matrixes to delay or eliminate drainage is the usual approach for decreasing drug loss but the alternative approach of chemically reducing tear turnover and/or solution drainage has not been investigated. By means of a simple isotopic dilution technique, using radioactive technetium sulfur colloid, the quantitative influence of topical anesthetics on tear production and instilled solution drainage was determined. The reduction in the rate of tear turnover and solution drainage varies for different anesthetics and is dose dependent. The implication of these results for some long accepted clinical procedures is discussed, and questions are raised regarding the present understanding of the mechanisms of tear production. Quantitation of precorneal drug loss through instilled solution drainage and tear turnover permits the establishment of a baseline for ocular drug bioavailability. Aqueous humor drug concentration versus time profiles of radioactive pilocarpine nitrate were obtained, both in the presence and absence of topical anesthesia. The results verify the importance of tear turnover and instilled solution drainage as a major route of drug loss in the eye. Moreover, the success of the present study in improving ocular drug bioavailability by the chemical approach of repressing solution drainage and tear turnover suggests that this approach is viable for improving drug bioavailability.
Komnenou, A T H; Kazakos, G M; Savvas, I; Thomas, A L N
2013-08-10
The influence of an anaesthetic protocol, which included medetomidine, propofol, carprofen and halothane on tear production in the dog. There are no previous studies on the effects of this combination on tear production in dogs or in any other species. The present study included 39 dogs, which underwent non-ophthalmic surgery in our clinic. Preanaesthetically, all dogs had normal tear production (18.62±3.65 mm/minute) as this was recorded with Schirmer tear test I (STT I) and the ophthalmologic examination did not reveal anything abnormal. Tear production readings were recorded before the administration of premedication, at the end of anaesthesia, one hour and two hours postanaesthesia. No reverse agent was administrated. At the end of anaesthesia (right eye (oculus dexter, OD) P<0.0005, left eye (oculus sinister, OS) P<0.0005), as well as one hour postanaesthesia (OD P=0.020, OS P=0.001) there was a statistically significant reduction in tear production, which returned to normal values two hours postanaesthesia, regardless of the duration of the operation. This anaesthetic combination resulted in a decrease in tear production and, therefore, the use of tear substitute treatment in dogs undergoing anaesthesia with this protocol (combination) from the time the sedative is given until at least two hours after the end of anaesthesia is highly recommended.
Baudouin, Christophe; Aragona, Pasquale; Messmer, Elisabeth M; Tomlinson, Alan; Calonge, Margarita; Boboridis, Kostas G; Akova, Yonca A; Geerling, Gerd; Labetoulle, Marc; Rolando, Maurizio
2013-10-01
Dry eye disease (DED), a multifactorial disease of the tears and ocular surface, is common and has a significant impact on quality of life. Reduced aqueous tear flow and/or increased evaporation of the aqueous tear phase leads to tear hyperosmolarity, a key step in the vicious circle of DED pathology. Tear hyperosmolarity gives rise to morphological changes such as apoptosis of cells of the conjunctiva and cornea, and triggers inflammatory cascades that contribute to further cell death, including loss of mucin-producing goblet cells. This exacerbates tear film instability and drives the cycle of events that perpetuate the condition. Traditional approaches to counteracting tear hyperosmolarity in DED include use of hypotonic tear substitutes, which have relatively short persistence in the eye. More recent attempts to counteract tear hyperosmolarity in DED have included osmoprotectants, small organic molecules that are used in many cell types throughout the natural world to restore cell volume and stabilize protein function, allowing adaptation to hyperosmolarity. There is now an expanding pool of clinical data on the efficacy of DED therapies that include osmoprotectants such as erythritol, taurine, trehalose and L-carnitine. Osmoprotectants in DED may directly protect cells against hyperosmolarity and thereby promote exit from the vicious circle of DED physiopathology. Copyright © 2013 The Authors. Published by Elsevier Inc. All rights reserved.
Dynamic measurement of the corneal tear film with a Twyman-Green interferometer
NASA Astrophysics Data System (ADS)
Micali, Jason D.; Greivenkamp, John E.; Primeau, Brian C.
2014-07-01
An interferometer for measuring dynamic properties of the in vivo tear film on the human cornea has been developed. The system is a near-infrared instantaneous phase-shifting Twyman-Green interferometer. The laser source is a 785 nm solidstate laser; the system has been carefully designed and calibrated to ensure that the system operates at eye safe levels. Measurements are made over a 6 mm diameter on the cornea. Successive frames of interferometric height measurements are combined to produce movies showing both the quantitative and qualitative changes in the topography of the tear film surface and structure. To date, measurement periods of up to 120 seconds at 28.6 frames per second have been obtained. Several human subjects have been examined using this system, demonstrating a surface height resolution of 25 nm and spatial resolution of 6 μm. Examples of features that have been observed in these in preliminary studies of the tear film include: post-blink disruption, evolution, and stabilization of the tear film; tear film artifacts generated by blinking; tear film evaporation and break-up; and the propagation of foreign objects in the tear film. This paper discusses the interferometer design and presents results from in vivo measurements.
Dynamic measurement of the corneal tear film with a Twyman-Green interferometer
NASA Astrophysics Data System (ADS)
Micali, Jason D.; Greivenkamp, John E.; Primeau, Brian C.
2015-05-01
An interferometer for measuring dynamic properties of the in vivo tear film on the human cornea has been developed. The system is a near-infrared instantaneous phase-shifting Twyman-Green interferometer. The laser source is a 785 nm solid-state laser, and the system has been carefully designed and calibrated to ensure that the system operates at eye-safe levels. Measurements are made over a 6 mm diameter on the cornea. Successive frames of interferometric height measurements are combined to produce movies showing both the quantitative and qualitative changes in the topography of the tear film surface and structure. To date, measurement periods of up to 120 s at 28.6 frames per second have been obtained. Several human subjects have been examined using this system, demonstrating a surface height resolution of 25 nm and spatial resolution of 6 μm. Examples of features that have been observed in these preliminary studies of the tear film include postblink disruption, evolution, and stabilization of the tear film; tear film artifacts generated by blinking; tear film evaporation and breakup; and the propagation of foreign objects in the tear film. This paper discusses the interferometer design and presents results from in vivo measurements.
Relevance of Lipid-Based Products in the Management of Dry Eye Disease.
Garrigue, Jean-Sébastien; Amrane, Mourad; Faure, Marie-Odile; Holopainen, Juha M; Tong, Louis
2017-11-01
Components of the ocular surface synergistically contribute to maintaining and protecting a smooth refractive layer to facilitate the optimal transmission of light. At the air-water interface, the tear film lipid layer (TFLL), a mixture of lipids and proteins, plays a key role in tear surface tension and is important for the physiological hydration of the ocular surface and for ocular homeostasis. Alterations in tear fluid rheology, differences in lipid composition, or downregulation of specific tear proteins are found in most types of ocular surface disease, including dry eye disease (DED). Artificial tears have long been a first line of treatment in DED and aim to replace or supplement tears. More recently, lipid-containing eye drops have been developed to more closely mimic the combination of aqueous and lipid layers of the TFLL. Over the last 2 decades, our understanding of the nature and importance of lipids in the tear film in health and disease has increased substantially. The aim of this article is to provide a brief overview of our current understanding of tear film properties and review the effectiveness of lipid-based products in the treatment of DED. Liposome lid sprays, emulsion eye drops, and other lipid-containing formulations are discussed.
NASA Astrophysics Data System (ADS)
Szczesna, Dorota H.; Kulas, Zbigniew; Kasprzak, Henryk T.; Stenevi, Ulf
2009-11-01
A lateral shearing interferometer was used to examine the smoothness of the tear film. The information about the distribution and stability of the precorneal tear film is carried out by the wavefront reflected from the surface of tears and coded in interference fringes. Smooth and regular fringes indicate a smooth tear film surface. On corneae after laser in situ keratomileusis (LASIK) or radial keratotomy (RK) surgery, the interference fringes are seldom regular. The fringes are bent on bright lines, which are interpreted as tear film breakups. The high-intensity pattern seems to appear in similar location on the corneal surface after refractive surgery. Our purpose was to extract information about the pattern existing under the interference fringes and calculate its shape reproducibility over time and following eye blinks. A low-pass filter was applied and correlation coefficient was calculated to compare a selected fragment of the template image to each of the following frames in the recorded sequence. High values of the correlation coefficient suggest that irregularities of the corneal epithelium might influence tear film instability and that tear film breakup may be associated with local irregularities of the corneal topography created after the LASIK and RK surgeries.
An Overview on Dry Eye Treatment: Approaches for Cyclosporin A Delivery
Yavuz, Burçin; Bozdağ Pehlivan, Sibel; Ünlü, Nurşen
2012-01-01
Dry eye syndrome (DES, Keratoconjunctivitis sicca) is a common disorder of the tear film caused by decreased tear production or increased evaporation. Changes in tear composition also promote inflammation on the ocular surface by various mechanisms. Artificial tear drops, tear retention treatment, stimulation of tear secretion, or anti-inflammatory drugs may be used for dry eye treatment according to the severity of the disease. For untreated patients, the risk of ocular infection increases at considerable level and clinical course of the disease may proceed up to infection, corneal ulcer, and blindness. Artificial tears and/or punctual occlusions are used for tear replacement or preservation. New treatment approaches are designed to modify the underlying disease process. For the treatment of severe dry eye disease, cyclosporin A (CsA), the first one of the new generation immunomodulatory drugs, which has an anti-inflammatory effect, is frequently used. CsA has immunosuppressive effects following systemic application. Following local administration of CsA, it is expected to obtain effective drug concentration at the target area and to avoid the various side effects associated with systemic delivery. Microspheres, implants, and liposomes have been developed for administration of CsA subconjunctivally in order to enhance its efficiency. PMID:22619624
Imada, Toshihiro; Nakamura, Shigeru; Kitamura, Naoki; Shibuya, Izumi; Tsubota, Kazuo
2014-01-01
Tears are secreted from the lacrimal gland (LG), a dysfunction in which induces dry eye, resulting in ocular discomfort and visual impairment. Honey bee products are used as a nutritional source in daily life and medicine; however, little is known about their effects on dry eye. The aim of the present study was to investigate the effects of honey bee products on tear secretion capacity in dry eye. We selected raw honey, propolis, royal jelly (RJ), pollen, or larva from commercially available honey bee products. Tear secretion capacity was evaluated following the oral administration of each honey bee product in a rat blink-suppressed dry eye model. Changes in tear secretion, LG ATP content, and LG mitochondrial levels were measured. RJ restored the tear secretion capacity and decrease in LG ATP content and mitochondrial levels to the largest extent. Royal jelly can be used as a preventative intervention for dry eye by managing tear secretion capacity in the LG.
The effect of benoxinate on the tear stability of Hong Kong-Chinese.
Cho, P; Brown, B
1995-07-01
We conducted a series of experiments to examine the effect of local anaesthetic instillation on tear stability measurements. All experiments were conducted with the examiner masked with respect to treatments. We measured tear break-up time (TDUT) and non-invasive tear break-up time (NITBUT) 30s after instillation of benoxinate (0.4%) in a single masked experiment and found that NITBUT was significantly increased while TBUT was unaffected. In separate experiments tear stability was assessed 5 min after instillation of benoxinate and there was no significant effect on either TBUT or NITBUT measurements. In a control experiment to examine the effect of instilling a drop of liquid into the eye, neither TBUT nor NITBUT were affected 30s after the instillation of saline. No corneal staining was observed in any of the subjects after instillation of benoxinate. The results suggest that benoxinate does not affect the stability of the precorneal tear film, and that tear stability can be assessed after the instillation of unpreserved benoxinate.
[Shoulder instability and rotator cuff tear].
Voigt, C; Lill, H
2009-01-01
A rotator cuff tear as a complication of anterior shoulder dislocation is well known in patients over 40 years old. The incidence of this accompanying injury correlates with the patient's age and the number of redislocations. The tear localization and dimension depend on the patient's age. To what extent these tears are a complication of shoulder dislocation is often unclear, as rotator cuff tears and glenohumeral instability interact. Reports on this combined injury pattern are rare, but based on the patient's age, activity level, and functional demand, therapeutic concepts have been devised. In active patients younger than 60 years and in cases of redislocation, both the rotator cuff tear and the capsule-labrum-ligament lesion should be reconstructed arthroscopically. In lesser active patients age 60 years or older, an isolated rotator cuff reconstruction is often sufficient to stabilize the glenohumeral joint. This treatment concept shows a predominantly good outcome.As a special form of anterior shoulder dislocation, a rotator cuff tear and a plexus brachialis lesion--the"terrible triad of the shoulder"--is described here.
Interaction of lysozyme with a tear film lipid layer model: A molecular dynamics simulation study.
Wizert, Alicja; Iskander, D Robert; Cwiklik, Lukasz
2017-12-01
The tear film is a thin multilayered structure covering the cornea. Its outermost layer is a lipid film underneath of which resides on an aqueous layer. This tear film lipid layer (TFLL) is itself a complex structure, formed by both polar and nonpolar lipids. It was recently suggested that due to tear film dynamics, TFLL contains inhomogeneities in the form of polar lipid aggregates. The aqueous phase of tear film contains lachrymal-origin proteins, whereby lysozyme is the most abundant. These proteins can alter TFLL properties, mainly by reducing its surface tension. However, a detailed nature of protein-lipid interactions in tear film is not known. We investigate the interactions of lysozyme with TFLL in molecular details by employing coarse-grained molecular dynamics simulations. We demonstrate that lysozyme, due to lateral restructuring of TFLL, is able to penetrate the tear lipid film embedded in inverse micellar aggregates. Copyright © 2017 Elsevier B.V. All rights reserved.
Freezing Range, Melt Quality, and Hot Tearing in Al-Si Alloys
NASA Astrophysics Data System (ADS)
Uludağ, Muhammet; Çetin, Remzi; Dispinar, Derya
2018-02-01
In this study, three different aluminum-silicon alloys (A356, A413, and A380) that have different solidification morphology and solidification ranges were examined with an aim to evaluate the hot tearing susceptibility. T-shape mold and Constrained Rod Casting (CRC) mold were used for the characterization. Reduced Pressure Test (RPT) was used to quantify the casting quality by measuring bifilm index. It was found that bifilm index and solidification range have an important role on the hot tearing formation. As it is known, bifilms can cause porosity and in this case, it was shown that porosity formed by bifilms decreased hot tearing tendency. As the freezing range of alloy increases, bifilms find the time to unravel that reduces hot tearing. However, for eutectic alloy (A413), due to zero freezing range, regardless of bifilm content, hot tearing was never observed. A380.1 alloy had the highest tendency for hot tearing due to having the highest freezing range among the alloys investigated in this work.
Inic-Kanada, Aleksandra; Nussbaumer, Andrea; Montanaro, Jacqueline; Belij, Sandra; Schlacher, Simone; Stein, Elisabeth; Bintner, Nora; Merio, Margarethe; Zlabinger, Gerhard J.
2012-01-01
Purpose Evaluating cytokine profiles in tears could shed light on the pathogenesis of various ocular surface diseases. When collecting tears with the methods currently available, it is often not possible to avoid the tear reflex, which may give a different cytokine profile compared to basal tears. More importantly, tear collection with glass capillaries, the most widely used method for taking samples and the best method for avoiding tear reflex, is impractical for remote area field studies because it is tedious and time-consuming for health workers, who cannot collect tears from a large number of patients with this method in one day. Furthermore, this method is uncomfortable for anxious patients and children. Thus, tears are frequently collected using ophthalmic sponges. These sponges have the advantage that they are well tolerated by the patient, especially children, and enable standardization of the tear collection volume. The aim of this study was to compare various ophthalmic sponges and extraction buffers to optimize the tear collection method for field studies for subsequent quantification of cytokines in tears using the Luminex technology. Methods Three ophthalmic sponges, Merocel, Pro-ophta, and Weck-Cel, were tested. Sponges were presoaked with 25 cytokines/chemokines of known concentrations and eluted with seven different extraction buffers (EX1–EX7). To assess possible interference in the assay from the sponges, two standard curves were prepared in parallel: 1) cytokines of known concentrations with the extraction buffers and 2) cytokines of known concentrations loaded onto the sponges with the extraction buffers. Subsequently, a clinical assessment of the chosen sponge-buffer combination was performed with tears collected from four healthy subjects using 1) aspiration and 2) sponges. To quantify cytokine/chemokine recovery and the concentration in the tears, a 25-plex Cytokine Panel and the Luminex xMap were used. This platform enables simultaneous measurement of proinflammatory cytokines, Th1/Th2 distinguishing cytokines, nonspecific acting cytokines, and chemokines. Results We demonstrated the following: (i) 25 cytokines/chemokines expressed highly variable interactions with buffers and matrices. Several buffers enabled recovery of similar cytokine values (regulated and normal T cell expressed and secreted [RANTES], interleukin [IL]-13, IL-6, IL-8, IL-2R, and granulocyte-macrophage colony-stimulating factor [GM-CSF]); others were highly variable (monocyte chemotactic protein-1 [MCP-1], monokine induced by interferon-gamma [MIG], IL-1β, IL-4, IL-7, and eotaxin). (ii) Various extraction buffers displayed significantly different recovery rates on the same sponge for the same cytokine/chemokine. (iii) The highest recovery rates were obtained with the Merocel ophthalmic sponge except for tumor necrosis factor-α: the Weck-Cel ophthalmic sponge showed the best results, either with cytokine standards loaded onto sponges or with tears collected from the inner canthus of the eye, using the sponge. (iv) IL-5, IL-10, and interferon-α were not detected in any tear sample from four normal human subjects. Twenty-two cytokines/chemokines that we detected were extracted from the Merocel sponge to a satisfactory recovery percentage. The recovery of IL-7 was significantly lower in the extracted Merocel sponge compared to the diluted tear samples. The cytokine/chemokine extraction from tears showed the same pattern of extraction that we observed for extracting the standards. Conclusions Simultaneous measurement of various cytokines using ophthalmic sponges yielded diverse results for various cytokines as the level of extraction differs noticeably for certain cytokines. A second set of controls (standard curves “with sponges”) should be used to delineate the extent of extraction for each cytokine to be analyzed. Many cytokines/chemokines were detected in tear samples collected with the Merocel sponge, including many that have been implicated in ocular surface disease. Luminex detection of cytokine/chemokine profiles of tears collected with Merocel sponges and extracted with buffer EX1 may be useful in clinical studies, for example, to assess cytokine profiles evaluation in ocular surface diseases. PMID:23233782
Inic-Kanada, Aleksandra; Nussbaumer, Andrea; Montanaro, Jacqueline; Belij, Sandra; Schlacher, Simone; Stein, Elisabeth; Bintner, Nora; Merio, Margarethe; Zlabinger, Gerhard J; Barisani-Asenbauer, Talin
2012-01-01
Evaluating cytokine profiles in tears could shed light on the pathogenesis of various ocular surface diseases. When collecting tears with the methods currently available, it is often not possible to avoid the tear reflex, which may give a different cytokine profile compared to basal tears. More importantly, tear collection with glass capillaries, the most widely used method for taking samples and the best method for avoiding tear reflex, is impractical for remote area field studies because it is tedious and time-consuming for health workers, who cannot collect tears from a large number of patients with this method in one day. Furthermore, this method is uncomfortable for anxious patients and children. Thus, tears are frequently collected using ophthalmic sponges. These sponges have the advantage that they are well tolerated by the patient, especially children, and enable standardization of the tear collection volume. The aim of this study was to compare various ophthalmic sponges and extraction buffers to optimize the tear collection method for field studies for subsequent quantification of cytokines in tears using the Luminex technology. Three ophthalmic sponges, Merocel, Pro-ophta, and Weck-Cel, were tested. Sponges were presoaked with 25 cytokines/chemokines of known concentrations and eluted with seven different extraction buffers (EX1-EX7). To assess possible interference in the assay from the sponges, two standard curves were prepared in parallel: 1) cytokines of known concentrations with the extraction buffers and 2) cytokines of known concentrations loaded onto the sponges with the extraction buffers. Subsequently, a clinical assessment of the chosen sponge-buffer combination was performed with tears collected from four healthy subjects using 1) aspiration and 2) sponges. To quantify cytokine/chemokine recovery and the concentration in the tears, a 25-plex Cytokine Panel and the Luminex xMap were used. This platform enables simultaneous measurement of proinflammatory cytokines, Th1/Th2 distinguishing cytokines, nonspecific acting cytokines, and chemokines. WE DEMONSTRATED THE FOLLOWING: (i) 25 cytokines/chemokines expressed highly variable interactions with buffers and matrices. Several buffers enabled recovery of similar cytokine values (regulated and normal T cell expressed and secreted [RANTES], interleukin [IL]-13, IL-6, IL-8, IL-2R, and granulocyte-macrophage colony-stimulating factor [GM-CSF]); others were highly variable (monocyte chemotactic protein-1 [MCP-1], monokine induced by interferon-gamma [MIG], IL-1β, IL-4, IL-7, and eotaxin). (ii) Various extraction buffers displayed significantly different recovery rates on the same sponge for the same cytokine/chemokine. (iii) The highest recovery rates were obtained with the Merocel ophthalmic sponge except for tumor necrosis factor-α: the Weck-Cel ophthalmic sponge showed the best results, either with cytokine standards loaded onto sponges or with tears collected from the inner canthus of the eye, using the sponge. (iv) IL-5, IL-10, and interferon-α were not detected in any tear sample from four normal human subjects. Twenty-two cytokines/chemokines that we detected were extracted from the Merocel sponge to a satisfactory recovery percentage. The recovery of IL-7 was significantly lower in the extracted Merocel sponge compared to the diluted tear samples. The cytokine/chemokine extraction from tears showed the same pattern of extraction that we observed for extracting the standards. Simultaneous measurement of various cytokines using ophthalmic sponges yielded diverse results for various cytokines as the level of extraction differs noticeably for certain cytokines. A second set of controls (standard curves "with sponges") should be used to delineate the extent of extraction for each cytokine to be analyzed. Many cytokines/chemokines were detected in tear samples collected with the Merocel sponge, including many that have been implicated in ocular surface disease. Luminex detection of cytokine/chemokine profiles of tears collected with Merocel sponges and extracted with buffer EX1 may be useful in clinical studies, for example, to assess cytokine profiles evaluation in ocular surface diseases.
Recent developments on dry eye disease treatment compounds.
Colligris, Basilio; Alkozi, Hanan Awad; Pintor, Jesus
2014-01-01
Dry eye syndrome is a common tears and ocular surface multifactorial disease, described by changes in the ocular surface epithelia related to reduced tears quantity and ocular surface sensitivity, leading to inflammatory reaction. Managing the eye inflammation proved helpful to patients with dry eye disease and current treatment is based on the use of topically applied artificial tear products/lubricants, tear retention management, stimulation of tear secretion and using anti-inflammatory drugs. In this article we revise the corresponding literature and patents assembling the new treatment approaches of novel and future pharmaceutical compounds destined for the dry eye disease treatment. The most frequent categories of compounds presented are secretagogues and anti-inflammatory drugs. These compounds are the research outcome of novel therapeutic strategies designed to reduce key inflammatory pathways and restore healthy tear film.
Failure strength of the bovine caudal disc under internal hydrostatic pressure.
Schechtman, Helio; Robertson, Peter A; Broom, Neil D
2006-01-01
The structure of the disc is both complex and inhomogeneous, and it functions as a successful load-bearing organ by virtue of the integration of its various structural regions. These same features also render it impossible to assess the failure strength of the disc from isolated tissue samples, which at best can only yield material properties. This study investigated the intrinsic failure strength of the intact bovine caudal disc under a simple mode of internal hydrostatic pressure. Using a hydraulic actuator, coloured hydrogel was injected under monitored pressure into the nucleus through a hollow screw insert which passed longitudinally through one of the attached vertebrae. Failure did not involve vertebra/endplate structures. Rather, failure of the disc annulus was indicated by the simultaneous manifestation of a sudden loss of gel pressure, a flood of gel colouration appearing in the outer annulus and audible fibrous tearing. A mean hydrostatic failure pressure of 18+/-3 MPa was observed which was approximated as a thick-wall hoop stress of 45+/-7 MPa. The experiment provides a measurement of the intrinsic strength of the disc using a method of internal hydrostatic loading which avoids any disruption of the complex architecture of the annular wall. Although the disc in vivo is subjected to a much more complex pattern of loading than is achieved using simple hydrostatic pressurization, this latter mode provides a useful tool for investigating alterations in intrinsic disc strength associated with prior loading history or degeneration.
Lactoferrin Levels in Tears are Increased by the Topical Application of Diadenosine Tetraphosphate.
Loma, Patricia; Guzman-Aranguez, Ana; Perez de Lara, Maria J; Pintor, Jesus
2016-09-01
This study was undertaken to determine the effect of the topical application of diadenosine tetraphosphate on lactoferrin levels in rabbit tears. Diadenosine tetraphosphate was topically instilled in a single-dose, tear samples were collected by micropipette and lactoferrin was measured by Enzyme-Linked ImmunoSorbent Assay (ELISA). The concentration of lactoferrin in rabbit tears was significantly increased 1 h after diadenosine tetraphosphate application, remaining elevated for 3 h more. This effect was blocked by P2 receptors antagonists. Topical application of diadenosine tetraphosphate stimulates the secretion of lactoferrin in rabbit tears through P2 receptor activation.
Facile Determination of Sodium Ion and Osmolarity in Artificial Tears by Sequential DNAzymes.
Kim, Eun Hye; Lee, Eun-Song; Lee, Dong Yun; Kim, Young-Pil
2017-12-07
Despite high relevance of tear osmolarity and eye abnormality, numerous methods for detecting tear osmolarity rely upon expensive osmometers. We report a reliable method for simply determining sodium ion-based osmolarity in artificial tears using sequential DNAzymes. When sodium ion-specific DNAzyme and peroxidase-like DNAzyme were used as a sensing and detecting probe, respectively, the concentration of Na⁺ in artificial tears could be measured by absorbance or fluorescence intensity, which was highly correlated with osmolarity over the diagnostic range ( R ² > 0.98). Our approach is useful for studying eye diseases in relation to osmolarity.
... They include tendinitis, bursitis, and injuries such as tears. Rotator cuff tendons can become inflamed from frequent ... to wear down, which can lead to a tear. Some tears are not painful, but others can ...
Zhang, Guang-Ying; Zheng, Lei; Shi, Hao; Qu, Su-Hui; Ding, Hong-Yu
2013-12-01
The purpose of this study was to investigate the accuracy of high-frequency ultrasonography in the diagnosis of injuries of medial patellofemoral ligaments (MPFLs), analyse the characteristics of MPFL injury and correlations between injury of the MPFL and articular cartilage of the inferomedial patella in patients with acute traumatic lateral patellar dislocation. High-frequency sonographic images of 49 patients with acute traumatic lateral patellar dislocations treated surgically were reviewed. The χ(2) tests were performed for statistical analysis. Twenty-eight cases of complete MPFL tear and 21 cases of partial MPFL tear were identified in operation, with 27 cases of MPFL tear located at their femoral attachment, 21 cases of tear at the patellar attachment and one case of midsubstance tear. The diagnostic accuracy of sonography regarding partial MPFL tear and complete MPFL tear was 89.8% and 89.8%. Among the patients with MPFL tear at the patellar attachment, eight and six cases were concomitant with chondral and osteochondral lesions in the inferomedial patella, respectively, in contrast to nine and six cases in patients with MPFL tear at the femoral attachment, respectively. There was no significant difference between the two locations described above regarding the prevalence rates of chondral or osteochondral lesions of the inferomedial patella (P=0.732, P=0.614). Among the patients with complete MPFL tear, 12 and 10 cases were concomitant with chondral and osteochondral lesions in the inferomedial patella, respectively, while six and two cases were concomitant with partial MPFL tear. There was no significant difference between the two types of injuries discussed above on the prevalence rates of chondral lesions of the inferomedial patella (P=0.305), but the prevalence rate of osteochondral lesions between the two types of injuries discussed above was statistically different (P=0.035). The MPFL is most easily injured at the femoral attachment, secondly at the patellar attachment. High-frequency ultrasonography is an accurate method in the diagnosis of an MPFL tear. There are neither significant differences on the prevalence rates of chondral or osteochondral lesions of the inferomedial patella between locations of MPFL injuries, nor significant difference on the prevalence rates of chondral lesions between MPFL injury types; but the complete MPFL tear is more often concomitant with inferomedial patellar osteochondral lesions than the partial MPFL tear. Copyright © 2013 Elsevier Ltd. All rights reserved.
Lee, Sung Hyun; Nam, Dae Jin; Kim, Se Jin; Kim, Jeong Woo
2017-09-01
The subscapularis tendon is essential in maintaining normal glenohumeral biomechanics. However, few studies have addressed the outcomes of tears extending to the subscapularis tendon in massive rotator cuff tears. To assess the clinical and structural outcomes of arthroscopic repair of massive rotator cuff tears involving the subscapularis. Cohort study; Level of evidence, 3. Between January 2010 and January 2014, 122 consecutive patients with massive rotator cuff tear underwent arthroscopic rotator cuff repair. Overall, 122 patients were enrolled (mean age, 66 years; mean follow-up period, 39.5 months). Patients were categorized into 3 groups based on subscapularis tendon status: intact subscapularis tendon (I group; n = 45), tear involving less than the superior one-third (P group; n = 35), and tear involving more than one-third of the subscapularis tendon (C group; n = 42). All rotator cuff tears were repaired; however, subscapularis tendon tears involving less than the superior one-third in P group were only debrided. Pain visual analog scale, Constant, and American Shoulder and Elbow Surgeons scores and passive range of motion were measured preoperatively and at the final follow-up. Rotator cuff integrity, global fatty degeneration index, and occupation ratio were determined via magnetic resonance imaging preoperatively and 6 months postoperatively. We identified 37 retears (31.1%) based on postoperative magnetic resonance imaging evaluation. Retear rate in patients in the C group (47.6%) was higher than that in the I group (22.9%) or P group (20.0%) ( P = .011). Retear subclassification based on the involved tendons showed that subsequent subscapularis tendon retears were noted in only the C group. The improvement in clinical scores after repair was statistically significant in all groups but not different among the groups. Between-group comparison showed significant differences in preoperative external rotation ( P = .021). However, no statistically significant difference was found in any shoulder range of motion measurements after surgery. Arthroscopic repair of massive tears results in substantial improvements in shoulder function, despite the presence of combined subscapularis tears. However, this study showed a high failure rate of massive posterosuperior rotator cuff tear repair extending more than one-third of the subscapularis tendon. When combined subscapularis tendon tear was less than the superior one-third of the subscapularis tendon, arthroscopic debridement was a reasonable treatment method where comparable clinical and anatomic outcomes could be expected.
NASA Astrophysics Data System (ADS)
Kim, Cheol-Woo; Cho, Jae-Ik; Choi, Se-Weon; Kim, Young-Chan; Kang, Chang-Seog
Recently, demand of aluminum alloys for use in high thermal conductivity application is increases but the most aluminum die casting alloys exhibit very lower thermal properties because of their high concentrations of alloying elements. However, those alloying elements are essential to obtain sufficient fluidity and mechanical strength. Therefore, the purpose of this study is to analyze the effect of alloying elements in die casting alloys, Si, Cu, Mg, Fe and Mn, in thermal conductivity, die casting characteristics and mechanical properties and find out the appropriate amount of each alloying element for development of heat sink component. The results showed that Mn had the most deleterious effect in thermal conductivity and Si and Fe contents were important to improve strength and limit casting defects, such as hot tearing and die soldering. The alloy with 0.2 1.0wt%Cu, 0.3 0.6wt%Fe and 1.0 2.0wt%Si showed very good combination of high thermal conductivity and good casting characteristics.
Liu, Kai; Chen, Lihui; Huang, Liulian; Ni, Yonghao; Sun, Bo
2015-03-06
The nanofibrillated cellulose (NFC) was used as substrates to carry triclosan (TCS), which was then applied as a coating agent for impacting antibacterial property to paper while also improving its strength. The TCS-loaded NFC material was further characterized. UV-vis spectra results showed that a characteristic absorption band at 282 nm was observed, which was attributed to triclosan, confirming its successful loading onto NFC. The antibacterial activity tests indicated that the coated paper exhibited excellent antibacterial activity against Escherichia coli, and the growth inhibition of bacteria (GIB) increased as the loading amount of triclosan coated on paper increased. The GIB can reach 98.7% when the 0.023 g TCS-loaded NFC was coated on paper. Meanwhile, the tensile and tear index of the coated paper increased by 18.0% and 26.4%, respectively compared to the blank paper. Therefore, the triclosan-loaded paper could be potentially used in the medical field. Copyright © 2014 Elsevier Ltd. All rights reserved.
Investigation of Microstructural Features Determining the Toughness of 980 MPa Bainitic Weld Metal
NASA Astrophysics Data System (ADS)
Cao, R.; Zhang, X. B.; Wang, Z.; Peng, Y.; Du, W. S.; Tian, Z. L.; Chen, J. H.
2014-02-01
The microstructural features that control the impact toughness of weld metals of a 980 MPa 8 pct Ni high-strength steel are investigated using instrumented Charpy V tester, optical microscope (OM), scanning electron microscope (SEM), transmission electron microscope (TEM), electron back-scattered diffraction (EBSD), and finite-element method (FEM) calculation. The results show that the critical event for cleavage fracture in this high-strength steel and weld metals is the propagation of a bainite packet-sized crack across the packet boundary into contiguous packets, and the bainitic packet sizes control the impact toughness. The high-angle misorientation boundaries detected in a bainite packet by EBSD form fine tear ridges on fracture surfaces. However, they are not the decisive factors controlling the cleavage fracture. The effects of Ni content are essential factors for improving the toughness. The extra large cleavage facets seriously deteriorate the toughness, which are formed on the interfaces of large columnar crystals growing in welding pools with high heat input.
Ververis, C; Georghiou, K; Danielidis, D; Hatzinikolaou, D G; Santas, P; Santas, R; Corleti, V
2007-01-01
Freshwater algal biomass and orange and lemon peels were assessed as tissue paper pulp supplements. Cellulose and hemicellulose contents of algal biomass were 7.1% and 16.3%, respectively, whereas for citrus peels cellulose content ranged from 12.7% to 13.6% and hemicellulose from 5.3% to 6.1%. For all materials, lignin and ash content was 2% or lower, rendering them suitable for use as paper pulp supplements. The addition of algal biomass to paper pulp increased its mechanical strength significantly. However, brightness was adversely affected by chlorophyll. The addition of citrus peels in paper pulp had no effect on breaking length, increased bursting strength and decreased tearing resistance. Brightness was negatively affected at proportions of 10%, because citrus peel particles behave as coloured pigments. The cost of both materials is about 45% lower than that of conventional pulp, resulting in a 0.9-4.5% reduction in final paper price upon their addition to the pulp.
76 FR 74704 - Folded Self-Mailers and Unenveloped Mailpieces
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-01
....14.8 or 3.14.9b through 3.14.9f. 3.15.2 Letter-Size Mailpieces With Tear-Off Strips When letter-size mailpieces have tear-off strips on the leading and/or trailing edge, any unfolded edges must be sealed with.... b. Tear-off strips may be up to \\9/16\\ inch (0.5625) wide. c. Tear lines (single lines of...
Leal, Mariana Ferreira; Astur, Diego Costa; Debieux, Pedro; Arliani, Gustavo Gonçalves; Silveira Franciozi, Carlos Eduardo; Loyola, Leonor Casilla; Andreoli, Carlos Vicente; Smith, Marília Cardoso; Pochini, Alberto de Castro; Ejnisman, Benno; Cohen, Moises
2015-01-01
The anterior cruciate ligament (ACL) is one of the most frequently injured structures during high-impact sporting activities. Gene expression analysis may be a useful tool for understanding ACL tears and healing failure. Reverse transcription-quantitative polymerase chain reaction (RT-qPCR) has emerged as an effective method for such studies. However, this technique requires the use of suitable reference genes for data normalization. Here, we evaluated the suitability of six reference genes (18S, ACTB, B2M, GAPDH, HPRT1, and TBP) by using ACL samples of 39 individuals with ACL tears (20 with isolated ACL tears and 19 with ACL tear and combined meniscal injury) and of 13 controls. The stability of the candidate reference genes was determined by using the NormFinder, geNorm, BestKeeper DataAssist, and RefFinder software packages and the comparative ΔCt method. ACTB was the best single reference gene and ACTB+TBP was the best gene pair. The GenEx software showed that the accumulated standard deviation is reduced when a larger number of reference genes is used for gene expression normalization. However, the use of a single reference gene may not be suitable. To identify the optimal combination of reference genes, we evaluated the expression of FN1 and PLOD1. We observed that at least 3 reference genes should be used. ACTB+HPRT1+18S is the best trio for the analyses involving isolated ACL tears and controls. Conversely, ACTB+TBP+18S is the best trio for the analyses involving (1) injured ACL tears and controls, and (2) ACL tears of patients with meniscal tears and controls. Therefore, if the gene expression study aims to compare non-injured ACL, isolated ACL tears and ACL tears from patients with meniscal tear as three independent groups ACTB+TBP+18S+HPRT1 should be used. In conclusion, 3 or more genes should be used as reference genes for analysis of ACL samples of individuals with and without ACL tears.
Human tear serotonin levels correlate with symptoms and signs of dry eye
Chhadva, Priyanka; Lee, Tinthu; Sarantopoulos, Constantine D.; Hackam, Abigail S.; McClellan, Allison L.; Felix, Elizabeth R.; Levitt, Roy C.; Galor, Anat
2015-01-01
Purpose Serotonin, a neurotransmitter known to be involved in nociceptor sensitization, is present in human tears. The purpose of this study was to correlate tear serotonin levels, as a marker of nociceptor sensitization, to facets of dry eye (DE) including symptoms and signs. Design Cross-sectional study Participants Sixty-two patients with normal eyelid and corneal anatomy were prospectively recruited from a Veterans Administration Ophthalmology Clinic over 11 months. Methods DE symptoms (Ocular Surface Disease Index [OSDI]), signs (tear break-up time [TBUT], corneal staining, and Schirmer’s score), and clinical descriptors of neuropathic ocular pain (NOP) (sensitivity to light and/or sensitivity to wind) were assessed. For tear analysis, each patient’s tears were collected after instilling 50µl of sterile saline to the lower cul-de-sac of each eye and using capillary action microcaps to collect the ocular wash. Tear serotonin levels were measured using enzyme-linked immunosorbent assay. Main Outcomes Measured Correlations between tear serotonin concentrations and DE symptoms and signs. Results The mean age of the population was 61±14 years and 84% (n=52) of the patients were male. Serotonin concentrations negatively correlated with Schirmer’s scores (r=−0.28; p=0.02), but did not correlate with other DE parameters, such as OSDI scores, sensitivity to light or wind, TBUT, or staining. According to our hypothesis, we divided patients into groups based on both DE symptoms and aqueous tear production; serotonin concentrations were found to be significantly higher in DE group 1 (OSDI≥6 and Schirmer’s<8) compared to both DE group 2 (OSDI≥6 and Schirmer’s≥8) and controls (OSDI<6 and Schirmer’s≥8). Patients in the DE group 2 more frequently complained of sensitivity to light (64%) and wind (67%) compared to the DE group 1 (40% and 60%, respectively) and controls (8% and 17%, respectively). Conclusion Patients with DE symptoms and aqueous tear deficiency had higher tear serotonin levels compared to those with DE symptoms but normal tear production and those without DE symptoms. PMID:25983214
Comparison of Medial and Lateral Meniscus Root Tears
Koo, Ji Hyun; Choi, Sang-Hee; Lee, Seung Ah; Wang, Joon Ho
2015-01-01
The meniscus root plays an essential role in maintaining the circumferential hoop tension and preventing meniscal displacement. Studies on meniscus root tears have investigated the relationship of osteoarthritis and an anterior cruciate ligament tear. However, few studies have directly compared the medial and lateral root tears. To assess the prevalence of meniscal extrusion and its relationship with clinical features in medial and lateral meniscus root tears, we performed a retrospective review of the magnetic resonance imaging (MRI) results of 42 knee patients who had meniscus posterior horn root tears and who had undergone arthroscopic operations. The presence of meniscal extrusion was evaluated and the exact extent was measured from the tibial margin. The results were correlated with arthroscopic findings. Clinical features including patients’ ages, joint abnormalities, and previous trauma histories were evaluated. Twenty-two patients had medial meniscus root tears (MMRTs) and twenty patients had lateral meniscus root tears (LMRTs). Meniscal extrusion was present in 18 MMRT patients and one LMRT patient. The mean extent of extrusion was 4.2mm (range, 0.6 to 7.8) in the MMRT group and 0.9mm (range, -1.9 to 3.4) in the LMRT group. Five patients with MMRT had a history of trauma, while 19 patients with LMRT had a history of trauma. Three patients with MMRT had anterior cruciate ligament (ACL) tears, while 19 patients with LMRT had ACL tears. The mean age of the patients was 52 years (range: 29–71 years) and 30 years (range: 14–62 years) in the MMRT and LMRT group, respectively. There was a significant correlation between a MMRT and meniscal extrusion (p<0.0001), and between an ACL tear and LMRT (p<0.0001). A history of trauma was significantly common in LMRT (p<0.0001). LMRT patients were significantly younger than MMRT patients (p<0.0001). Kellgren-Lawrence (K-L) grade differed significantly between MMRT and LMRT group (p<0.0001). Meniscal extrusion is common in patients with MMRTs. However, it is rare in patients with LMRTs, which are more commonly associated with a history of trauma and ACL tears. PMID:26488288
Comparison of Medial and Lateral Meniscus Root Tears.
Koo, Ji Hyun; Choi, Sang-Hee; Lee, Seung Ah; Wang, Joon Ho
2015-01-01
The meniscus root plays an essential role in maintaining the circumferential hoop tension and preventing meniscal displacement. Studies on meniscus root tears have investigated the relationship of osteoarthritis and an anterior cruciate ligament tear. However, few studies have directly compared the medial and lateral root tears. To assess the prevalence of meniscal extrusion and its relationship with clinical features in medial and lateral meniscus root tears, we performed a retrospective review of the magnetic resonance imaging (MRI) results of 42 knee patients who had meniscus posterior horn root tears and who had undergone arthroscopic operations. The presence of meniscal extrusion was evaluated and the exact extent was measured from the tibial margin. The results were correlated with arthroscopic findings. Clinical features including patients' ages, joint abnormalities, and previous trauma histories were evaluated. Twenty-two patients had medial meniscus root tears (MMRTs) and twenty patients had lateral meniscus root tears (LMRTs). Meniscal extrusion was present in 18 MMRT patients and one LMRT patient. The mean extent of extrusion was 4.2mm (range, 0.6 to 7.8) in the MMRT group and 0.9mm (range, -1.9 to 3.4) in the LMRT group. Five patients with MMRT had a history of trauma, while 19 patients with LMRT had a history of trauma. Three patients with MMRT had anterior cruciate ligament (ACL) tears, while 19 patients with LMRT had ACL tears. The mean age of the patients was 52 years (range: 29-71 years) and 30 years (range: 14-62 years) in the MMRT and LMRT group, respectively. There was a significant correlation between a MMRT and meniscal extrusion (p<0.0001), and between an ACL tear and LMRT (p<0.0001). A history of trauma was significantly common in LMRT (p<0.0001). LMRT patients were significantly younger than MMRT patients (p<0.0001). Kellgren-Lawrence (K-L) grade differed significantly between MMRT and LMRT group (p<0.0001). Meniscal extrusion is common in patients with MMRTs. However, it is rare in patients with LMRTs, which are more commonly associated with a history of trauma and ACL tears.
Location of Rotator Cuff Tear Initiation: A Magnetic Resonance Imaging Study of 191 Shoulders.
Jeong, Jeung Yeol; Min, Seul Ki; Park, Keun Min; Park, Yong Bok; Han, Kwang Joon; Yoo, Jae Chul
2018-03-01
Degenerative rotator cuff tears (RCTs) are generally thought to originate at the anterior margin of the supraspinatus tendon. However, a recent ultrasonography study suggested that they might originate more posteriorly than originally thought, perhaps even from the isolated infraspinatus (ISP) tendon, and propagate toward the anterior supraspinatus. Hypothesis/Purpose: It was hypothesized that this finding could be reproduced with magnetic resonance imaging (MRI). The purpose was to determine the most common location of degenerative RCTs by using 3-dimensional multiplanar MRI reconstruction. It was assumed that the location of the partial-thickness tears would identify the area of the initiation of full-thickness tears. Cross-sectional study; Level of evidence, 3. A retrospective analysis was conducted including 245 patients who had RCTs (nearly full- or partial-thickness tears) at the outpatient department between January 2011 and December 2013. RCTs were measured on 3-dimensional multiplanar reconstruction MRI with OsiriX software. The width and distance from the biceps tendon to the anterior margin of the tear were measured on T2-weighted sagittal images. In a spreadsheet, columns of consecutive numbers represented the size of each tear (anteroposterior width) and their locations with respect to the biceps brachii tendon. Data were pooled to graphically represent the width and location of all tears. Frequency histograms of the columns were made to visualize the distribution of tears. The tears were divided into 2 groups based on width (group A, <10 mm; group B, <20 and ≥10 mm) and analyzed for any differences in location related to size. The mean width of all RCTs was 11.9 ± 4.1 mm, and the mean length was 11.1 ± 5.0 mm. Histograms showed the most common location of origin to be 9 to 10 mm posterior to the biceps tendon. The histograms of groups A and B showed similar tear location distributions, indicating that the region approximately 10 mm posterior to the biceps tendon is the most common site of tear initiation. These results demonstrate that degenerative RCTs most commonly originate from approximately 9 to 10 mm posterior to the biceps tendon.
Ohguchi, Takeshi; Kojima, Takashi; Ibrahim, Osama M; Nagata, Taeko; Shimizu, Takahiko; Shirasawa, Takuji; Kawakita, Tetsuya; Satake, Yoshiyuki; Tsubota, Kazuo; Shimazaki, Jun; Ishida, Susumu
2013-11-21
To investigate the efficacy of 2% rebamipide ophthalmic solution on the tear functions and ocular surface status of the superoxide dismutase-1(Sod1(-/-)) mice. Two percent Rebamipide ophthalmic solution was applied to 40-week-old male Sod1(-/-) and wild-type (WT) mice four times a day for 2 weeks. We examined the cytokine concentrations in the tear fluid (by CytoBead assay), tear film break-up time, amount of tear production, and expressions of mucins 1, 4, and 5AC, by RT-PCR. We also performed vital staining of the ocular surface, PAS staining for muc5AC, and immunohistochemical stainings for 4-hydroxy-2-nonenal (4-HNE), 8-hydroxy-2'-deoxyguanosine (8-OHdG), in the conjunctiva to compare the results before and after rebamipide instillations. The tear functions and ocular surface epithelial damage scores were significantly worse in the Sod1(-/-) than in the WT mice. Application of 2% rebamipide for 2 weeks significantly improved the tear film break-up time, the amount of tear production, and the corneal epithelial damage scores, which also significantly increased the conjunctival goblet cell density and muc5 mRNA expression, in the Sod1(-/-) mice. The mean IL-6, IL-17, TNF-α, and IFN-γ levels in the tear fluid were reduced significantly along with a significant decrease in the density of cells positive for 4-HNE and 8-OHdG in the conjunctiva. Two percent Rebamipide ophthalmic solution significantly improved the tear stability and corneal epithelial damage, and enhanced the expression of muc5 mRNA on the ocular surface. We also observed anti-inflammatory effects in the tear film together with antioxidative effects in the conjunctiva, suggesting the efficacy of rebamipide in age-related dry eye disease attributable to SOD1 knockout.
Comparison of camel tear proteins between summer and winter
Chen, Ziyan; Shamsi, Farrukh A.; Li, Kaijun; Huang, Qiang; Al-Rajhi, Ali A.; Chaudhry, Imtiaz A.
2011-01-01
Purpose Proteins in the tear fluid have positive effects on maintaining the integrity and stabilization of the tear film, which is affected by several environmental factors. The aim of this study is to investigate seasonal variation of protein patterns in camel tears collected during the summer and winter season. Methods Tears from both eyes of 50 clinically normal camels (Camelus dromedarius) were collected in the summer (June – July) and in the winter (December – January) respectively. Pooled tear protein samples from two seasons were separated by SDS–PAGE and two-dimensional electrophoresis (2-DE). Protein spots of differential expression in two season gels were excised and subjected to in-gel digestion and identification by matrix assisted laser desorption/ionization-time of flight/time of flight-mass spectrum (MALDI-TOF/TOF-MS) analysis. Two differentially expressed proteins, lactoferrin (LF) and vitelline membrane outer layer protein 1 homolog (VMO1 homolog), were validated by western blotting. Results Thirteen well resolved bands were detected in SDS–PAGE gels of both summer and winter camel tears. By band densitometry, significantly higher intensities of band 6, 7, 11, and lower intensity of band 13 were observed in the summer group compared to the winter group. In 2-DE profiles of camel tears, four protein spots were found expressed differentially in two seasons. Further protein identification by MALDI-TOF/TOF-MS and confirmation by western blotting indicated that there was a significant decrease in LF (p=0.002) and an increase in VMO1 homolog (p=0.042) in tears in the summer compared to the winter. Conclusions The seasonal variation of camel tear fluids has been found in the composition of proteins, including LF and VMO1 homolog. This result will expand our knowledge of physiologic characteristics of tear fluids and establish a foundation for the mechanistic studies and clinical practices on ocular surface disorders. PMID:21293736
Does the Rotator Cuff Tear Pattern Influence Clinical Outcomes After Surgical Repair?
Watson, Scott; Allen, Benjamin; Robbins, Chris; Bedi, Asheesh; Gagnier, Joel J.; Miller, Bruce
2018-01-01
Background: Limited literature exists regarding the influence of rotator cuff tear morphology on patient outcomes. Purpose: To determine the effect of rotator cuff tear pattern (crescent, U-shape, L-shape) on patient-reported outcomes after rotator cuff repair. Study Design: Cohort study; Level of evidence, 3. Methods: Patients undergoing arthroscopic repair of known full-thickness rotator cuff tears were observed prospectively at regular intervals from baseline to 1 year. The tear pattern was classified at the time of surgery as crescent, U-shaped, or L-shaped. Primary outcome measures were the Western Ontario Rotator Cuff Index (WORC), the American Shoulder and Elbow Surgeons (ASES), and a visual analog scale (VAS) for pain. The tear pattern was evaluated as the primary predictor while controlling for variables known to affect rotator cuff outcomes. Mixed-methods regression and analysis of variance (ANOVA) were used to examine the effects of tear morphology on patient-reported outcomes after surgical repair from baseline to 1 year. Results: A total of 82 patients were included in the study (53 male, 29 female; mean age, 58 years [range, 41-75 years]). A crescent shape was the most common tear pattern (54%), followed by U-shaped (25%) and L-shaped tears (21%). There were no significant differences in outcome scores between the 3 groups at baseline. All 3 groups showed statistically significant improvement from baseline to 1 year, but analysis failed to show any predictive effect in the change in outcome scores from baseline to 1 year for the WORC, ASES, or VAS when tear pattern was the primary predictor. Further ANOVA also failed to show any significant difference in the change in outcome scores from baseline to 1 year for the WORC (P = .96), ASES (P = .71), or VAS (P = .86). Conclusion: Rotator cuff tear pattern is not a predictor of functional outcomes after arthroscopic rotator cuff repair. PMID:29623283
Choi, Won; Lian, Cui; Ying, Li; Kim, Ga Eon; You, In Cheon; Park, Soo Hyun; Yoon, Kyung Chul
2016-09-01
To investigate the expression of lipid peroxidation markers in the tear film and ocular surface and their correlation with disease severity in patients with dry eye disease. The concentrations of hexanoyl-lysine (HEL), 4-hydroxy-2-nonenal (HNE), and malondialdehyde (MDA) were measured with enzyme-linked immunosorbent assays in tears obtained from 44 patients with non-Sjogren syndrome dry eye and 33 control subjects. The correlations between the marker levels and the tear film and ocular surface parameters, including tear film break-up time (BUT), Schirmer tear value, tear clearance rate, keratoepitheliopathy scores, corneal sensitivity, conjunctival goblet cell density, and symptom score, were analyzed. The expression of the lipid peroxidation markers HEL, 4-HNE, and MDA in the conjunctiva was evaluated using immunohistochemistry. The concentrations of HEL, 4-HNE, and MDA were 279.84 ± 69.98 nmol/L, 0.02 ± 0.01 μg/mL, and 3.80 ± 1.05 pmol/mg in control subjects and 283.21 ± 89.67 nmol/L (p = 0.97), 0.20 ± 0.03 μg/mL (p < 0.01), and 13.32 ± 4.03 pmol/mg (p < 0.01) in dry eye patients. 4-HNE and MDA levels significantly correlated with BUT, Schirmer tear value, tear clearance rate, keratoepitheliopathy scores, conjunctival goblet cell density, and symptom score (p < 0.05), whereas HEL levels did not correlate with these parameters. Staining intensities for 4-HNE and MDA increased in dry eye patients. The expression of late lipid peroxidation markers, 4-HNE and MDA, increases in the tear film and ocular surface of patients with dry eye. The levels correlate with various tear film and ocular surface parameters and may reflect the severity of dry eye disease.
Does the Rotator Cuff Tear Pattern Influence Clinical Outcomes After Surgical Repair?
Watson, Scott; Allen, Benjamin; Robbins, Chris; Bedi, Asheesh; Gagnier, Joel J; Miller, Bruce
2018-03-01
Limited literature exists regarding the influence of rotator cuff tear morphology on patient outcomes. To determine the effect of rotator cuff tear pattern (crescent, U-shape, L-shape) on patient-reported outcomes after rotator cuff repair. Cohort study; Level of evidence, 3. Patients undergoing arthroscopic repair of known full-thickness rotator cuff tears were observed prospectively at regular intervals from baseline to 1 year. The tear pattern was classified at the time of surgery as crescent, U-shaped, or L-shaped. Primary outcome measures were the Western Ontario Rotator Cuff Index (WORC), the American Shoulder and Elbow Surgeons (ASES), and a visual analog scale (VAS) for pain. The tear pattern was evaluated as the primary predictor while controlling for variables known to affect rotator cuff outcomes. Mixed-methods regression and analysis of variance (ANOVA) were used to examine the effects of tear morphology on patient-reported outcomes after surgical repair from baseline to 1 year. A total of 82 patients were included in the study (53 male, 29 female; mean age, 58 years [range, 41-75 years]). A crescent shape was the most common tear pattern (54%), followed by U-shaped (25%) and L-shaped tears (21%). There were no significant differences in outcome scores between the 3 groups at baseline. All 3 groups showed statistically significant improvement from baseline to 1 year, but analysis failed to show any predictive effect in the change in outcome scores from baseline to 1 year for the WORC, ASES, or VAS when tear pattern was the primary predictor. Further ANOVA also failed to show any significant difference in the change in outcome scores from baseline to 1 year for the WORC ( P = .96), ASES ( P = .71), or VAS ( P = .86). Rotator cuff tear pattern is not a predictor of functional outcomes after arthroscopic rotator cuff repair.
Gyftopoulos, Soterios; Beltran, Luis S; Gibbs, Kevin; Jazrawi, Laith; Berman, Phillip; Babb, James; Meislin, Robert
2016-01-01
The purpose of this study was to see if 3-dimensional (3D) magnetic resonance imaging (MRI) could improve our understanding of rotator cuff tendon tear shapes. We believed that 3D MRI would be more accurate than two-dimensional (2D) MRI for classifying tear shapes. We performed a retrospective review of MRI studies of patients with arthroscopically proven full-thickness rotator cuff tears. Two orthopedic surgeons reviewed the information for each case, including scope images, and characterized the shape of the cuff tear into crescent, longitudinal, U- or L-shaped longitudinal, and massive type. Two musculoskeletal radiologists reviewed the corresponding MRI studies independently and blind to the arthroscopic findings and characterized the shape on the basis of the tear's retraction and size using 2D MRI. The 3D reconstructions of each cuff tear were reviewed by each radiologist to characterize the shape. Statistical analysis included 95% confidence intervals and intraclass correlation coefficients. The study reviewed 34 patients. The accuracy for differentiating between crescent-shaped, longitudinal, and massive tears using measurements on 2D MRI was 70.6% for reader 1 and 67.6% for reader 2. The accuracy for tear shape characterization into crescent and longitudinal U- or L-shaped using 3D MRI was 97.1% for reader 1 and 82.4% for reader 2. When further characterizing the longitudinal tears as massive or not using 3D MRI, both readers had an accuracy of 76.9% (10 of 13). The overall accuracy of 3D MRI was 82.4% (56 of 68), significantly different (P = .021) from 2D MRI accuracy (64.7%). Our study has demonstrated that 3D MR reconstructions of the rotator cuff improve the accuracy of characterizing rotator cuff tear shapes compared with current 2D MRI-based techniques. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Naranje, Sameer; Mittal, Ravi; Nag, Hiralal; Sharma, Raju
2008-09-01
We performed this prospective study to evaluate the incidence of meniscus tears arthroscopically and the effectiveness of magnetic resonance imaging (MRI) in detecting these lesions in patients with chronic anterior cruciate ligament (ACL)-deficient knees. We reviewed 50 patients (46 male and 4 female) with a mean age of 27 years (range, 18 to 48 years) who underwent ACL reconstruction for chronic ACL tears. Injuries were classified as chronic because arthroscopy was performed after more than 6 weeks of injury. All 50 patients had clinical and MRI evaluation followed by knee arthroscopy. The MRI and arthroscopic findings were then analyzed by a single independent reviewer. The presence of meniscus tears and their morphologic types and locations were analyzed. The sensitivity, specificity, positive predictive value, and negative predictive value of MRI were calculated. On arthroscopy, a medial meniscus tear was found in 18 patients (36%), a lateral meniscus tear was found in 11 patients (22%), both menisci were torn in 8 patients (16%), and no meniscus lesion was found in 13 patients (26%). The most common morphologic type of tear seen in the medial meniscus was "complex" (n = 11 [42%]), and that in the lateral meniscus was "longitudinal" (n = 10 [53%]). The posterior horn of the meniscus was the most common tear site. The overall sensitivity, specificity, positive predictive value, and negative predictive value for detecting meniscus tears in chronic ACL-deficient knees on MRI were 90%, 89%, 87%, 93%, respectively. We conclude from our study that in chronic ACL-deficient patients, the prevalence of posterior horn medial meniscus tears seems to be high. Anterior horn tears and radial and horizontal patterns of meniscus tears seem to be rare in chronic ACL deficiency. MRI correlates well with arthroscopy and has high negative predictive values. Level I, prognostic prospective study.
Xu, Jingjing; Bao, Jinhua; Deng, Jun; Lu, Fan; He, Ji C
2011-07-29
To measure dynamic change characteristics of spatial and temporal variations in the post-blink tear film of normal eyes. A wavefront sensor was used to measure dynamic changes in wavefront aberrations, up to the seventh order, for 10 seconds in a group of 33 normal young adults. Tear menisci were imaged with an anterior segment optical coherence tomography (AS-OCT) system and tear film break-up times (TFBUTs) were determined. Systematic changes in main axis astigmatism (R(2) = 0.933, P < 0.0001), vertical coma (R(2) = 0.935, P < 0.0001) and spherical aberrations (R(2) = 0.879, P = 0.0002) occurred during the 10-second post-blink period. Both lower tear meniscus height and area increased by 10 seconds compared with the initial levels (P < 0.0001 for each). The change of vertical coma had significant correlation with the increase of lower tear meniscus areas during the 10-second post-blink period (R(2) = 0.181, P = 0.014). Subjects with TFBUTs < 15 seconds had significantly increased main axis astigmatism, vertical coma, and spherical aberrations by 10 seconds. Subjects with longer TFBUTs did not have any significant wavefront aberrations during that period. Systematic changes in some Zernike aberrations after blinking are associated with the changes in tear menisci and TFBUT. There was a substantial individual variation in dynamic changes of Zernike aberrations, suggesting the necessity to explore individual differences in tear quality and tear performance. Dynamic wavefront measurement combined with anterior segment optical coherence tomography could provide a useful tool to understand spatial and temporal processes of the tear film in clinical practice.
Immunoglobulin Concentration in Tears of Contact Lens Wearers
Maurya, Rajendra P.; Bhushan, Prashant; Singh, Virendra P.; Singh, Mahendra K.; Kumar, Prakash; Bhatia, Ravindra P.S.; Singh, Usha
2014-01-01
Purpose: To evaluate changes in the concentration of tear immunoglobulins in contact lens wearers. Methods: A total of 45 cases including 23 contact lens wearers (43 eyes) and 22 age and sex matched healthy controls having no ocular pathology were studied for immunoglobulins (IgA, IgG, IgM) in their tears by single radial immunodiffusion method. Results: Most of the cases used soft (56.6%) and semi-soft gas permeable (30.4%) contact lenses. Tear IgM was detected in only 17.4% and tear IgG in 43.6% of contact lens wearers, while in controls IgG was detected in 9.1% but none of the controls had IgM. There was a significant rise in total tear IgA (13.17 ± 4.44 mg/dl) in contact lens wearer as compared to controls (8.93 ± 3.79 mg/dl). Rise of tear IgA was more in symptomatic patients (15.38 ± 5.28 mg/dl) and in those wearing hard (19.73 ± 5.43 mg/dl) and semi-soft contact lenses (13.31 ± 5.43 mg/dl). A significant increase in tear IgA was noticed in subjects wearing lenses for >3 years (15.69 ± 5.39 mg/dl). About 43.4% of lens wearers were symptomatic and 80% of their lenses showed deposits and/or haziness. All cases with IgM in tear were symptomatic. Conclusion: The relation of immunoglobulin concentration with increasing duration of wear and material of contact lens shows that tear immunoglobulin rise accrues due to mechanical stimulation, hence contact lenses should not be used for a long period and lenses of hard nature should be discouraged. The maintenance, cleaning and deproteinization of the lenses are of high importance to avoid immunostimulation. PMID:25667732
Assessment of tear osmolarity and other dry eye parameters in post-LASIK eyes.
Hassan, Ziad; Szalai, Eszter; Berta, Andras; Modis, Laszlo; Nemeth, Gabor
2013-07-01
To assess the tear osmolarity using the TearLab device after laser in situ keratomileusis (LASIK) and to compare the values with those obtained by traditional tear film tests before and after the procedure. Thirty eyes of 15 refractive surgery candidates (5 men and 10 women of mean age: 30.55 ± 11.79 years) were examined. Using a special questionnaire (Ocular Surface Disease Index), subjective dry eye complaints were evaluated, and then, the tear osmolarity was measured with the TearLab system (TearLab Corporation) and conventional dry eye tests were carried out. Examinations were performed preoperatively and at 1, 30, and 60 days after the surgery. The mean value of tear osmolarity was 303.62 ± 12.29 mOsm/L before the surgery and 303.58 ± 20.14 mOsm/L at 60 days after the treatment (P = 0.69). Mean lid parallel conjunctival folds value was 0.68 ± 0.68 before the procedure and 0.58 ± 0.65 subsequent to surgery (P = 0.25). Meibomian gland dysfunction was not detected. No significant deviation was observed in the values of Schirmer test, corneal staining, tear break-up time, and lid parallel conjunctival folds when compared with postoperatively obtained values during the follow-up period (P > 0.05). During LASIK flap creation, intact corneal innervation is damaged, and the ocular surface lacrimal functional unit can be impaired. In our study, no abnormal dry eye test results were observed before or after the procedure. Based on our results, LASIK treatment is safe for dry eye involving the administration of adequate artificial tears for a minimum of 3 months.
Post-blink tear film dynamics in healthy and dry eyes during spontaneous blinking.
Szczesna-Iskander, Dorota H
2018-01-01
The aim was to investigate the dynamics of post-blink tear film leveling in natural blinking conditions (NBC) for healthy subjects and those diagnosed with dry eye syndrome (DES) and to relate this phase to the tear film surface quality (TFSQ) before the following blink. The study included 19 healthy persons and 10 with dry eye, grouped according to symptoms and signs observed during examination. Lateral shearing interferometry was used to examine TFSQ. Post-blink tear film dynamics was modeled by an exponential function, characterized by the decay parameter b, and a constant, describing the level of the stabilized TFSQ. Pre-next-natural-blink TFSQ dynamics was modeled with a linear trend, described by a parameter A. The post-blink tear film dynamics reached its plateau at a significantly (P = 0.006) lower level in the normal tear film group than in the dry eye group. The median exponential decay parameter b was statistically significantly higher for the control group than for the DES group, P = 0.026. The parameter b calculated for each interblink interval was significantly correlated with the corresponding parameter A (Spearman's R = 0.35; P < 0.001). Correlation between the median b and tear film fluorescein break-up time for each subject was also found (R = 0.41, P = 0.029). Significantly faster leveling of post-natural-blink tear film was observed in the group with DES than in healthy eyes. This dynamic was correlated with the pre-next-natural-blink TFSQ and tear film stability. The results of this pilot study support previous works that advocate the importance of polar lipids in the mechanism of tear film lipid spreading. Copyright © 2017 Elsevier Inc. All rights reserved.
Demiryay, Elvan; Yaylali, Volkan; Cetin, Ebru Nevin; Yildirim, Cem
2011-09-01
The aim was to compare the effects of topical cyclosporine A and artificial tears combination with artificial tears alone in patients with dysfunctional tear syndrome (DTS). Forty-two eyes of 42 patients with DTS were enrolled in the study. The inclusion criteria for the study were Schirmer I (without anesthesia) scores below 10 mm/5 min and tear film break-up time (BUT) below 10 sec. The patients were randomly divided into two groups. The study group (22 patients) underwent 0.05% cyclosporine A treatment twice a day and preservative-free artificial tears for four times a day for 4 months. The control group (20 patients) was administered only preservative-free artificial tears four times a day for 4 months. The BUT, Schirmer test scores, corneal fluorescein staining, conjunctival lissamine green staining, and goblet cell density derived by impression cytology were recorded before and after treatment in each group. In the study group, all parameters improved statistically significantly after treatment at the 4-month follow-up compared with the pretreatment values (P<0.001 for all). In the control group, corneal fluorescein staining (P<0.001) and conjunctival lissamine green staining (P=0.014) improved, but BUT and Schirmer scores did not change significantly after treatment. At the end of the 4-month follow-up, the study group demonstrated statistically significantly better BUT (P=0.020), Schirmer scores (P=0.002), goblet cell density (P=0.006), corneal fluorescein staining (P=0.003), and conjunctival lissamine green staining (P=0.017) scores than did the control group. Topical cyclosporine A and artificial tears treatment significantly increases goblet cell density, decreases the signs of DTS, and improves ocular surface health.
Laurie, Diane E.; Splan, Rebecca K.; Green, Kari; Still, Katherine M.; McKown, Robert L.; Laurie, Gordon W.
2012-01-01
Purpose. Lacritin is a human tear glycoprotein that promotes basal tear protein secretion in cultured rat lacrimal acinar cells and proliferation of subconfluent human corneal epithelial cells. When topically added to rabbit eyes, lacritin promotes basal tearing. Despite these activities on several species, lacritin's presence in nonprimate tears or other tissues has not been explored. Here we probed for lacritin in normal horse tears. Methods. Sequences were collected from the Ensembl genomic alignment of human LACRT gene with high-quality draft horse genome (EquCab2.0) and analyzed. Normal horse tears were collected and assayed by Western blotting, ELISA, and mass spectrometry. Newly generated rabbit antibodies, respectively, against N- and C-terminal regions of human lacritin were employed. Results. Identity was 75% and 45%, respectively, at nucleotide and protein levels. Structural features were conserved, including a C-terminal amphipathic α-helix. Anti-C-terminal antibodies strongly detected a ∼13 kDa band in horse tears that was validated by mass spectrometry. In human tears, the same antibody detected uncleaved lacritin (∼24 kDa) strongly and C-terminal fragments of ∼13 and ∼11 kDa weakly. Anti-N-terminal antibodies were slightly reactive with a ∼24 kDa horse antigen and showed no reaction with the anti-C-terminal–reactive ∼13 kDa species. Similar respective levels of horse C-terminal versus N-terminal immunoreactivity were apparent by ELISA. Conclusions. Lacritin is present in horse tears, largely as a C-terminal fragment homologous to the mitogenic and bactericidal region in human lacritin, suggesting potential benefit in corneal wound repair. PMID:22871838
Microarray-based IgE detection in tears of patients with vernal keratoconjunctivitis.
Leonardi, Andrea; Borghesan, Franco; Faggian, Diego; Plebani, Mario
2015-11-01
A specific allergen sensitization can be demonstrated in approximately half of the vernal keratoconjunctivitis (VKC) patients by conventional allergic tests. The measurement of specific IgE in tears using a multiplex allergen microarray may offer advantages to identify local sensitization to a specific allergen. In spring-summer 2011, serum and tears samples were collected from 10 active VKC patients (three females, seven males) and 10 age-matched normal subjects. Skin prick test, symptoms score and full ophthalmological examination were performed. Specific serum and tear IgE were assayed using ImmunoCAP ISAC, a microarray containing 103 components derived from 47 allergens. Normal subjects resulted negative for the presence of specific IgE both in serum and in tears. Of the 10 VKC patients, six resulted positive to specific IgE in serum and/or tears. In three of these six patients, specific IgE was found positive only in tears. Cross-reactivity between specific markers was found in three patients. Grass, tree, mites, animal but also food allergen-specific IgE were found in tears. Conjunctival provocation test performed out of season confirmed the specific local conjunctival reactivity. Multiple specific IgE measurements with single protein allergens using a microarray technique in tear samples are a useful, simple and non-invasive diagnostic tool. ImmunoCAP ISAC detects allergen sensitization at component level and adds important information by defining both cross- and co-sensitization to a large variety of allergen molecules. The presence of specific IgE only in tears of VKC patients reinforces the concept of possible local sensitization. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Posterior root tear of the medial and lateral meniscus.
Petersen, Wolf; Forkel, Philipp; Feucht, Matthias J; Zantop, Thore; Imhoff, Andreas B; Brucker, Peter U
2014-02-01
An avulsion of the tibial insertion of the meniscus or a radial tear close to the meniscal insertion is defined as a root tear. In clinical practice, the incidence of these lesions is often underestimated. However, several biomechanical studies have shown that the effect of a root tear is comparable to a total meniscectomy. Clinical studies documented progredient arthritic changes following root tears, thereby supporting basic science studies. The clinical diagnosis is limited by unspecific symptoms. In addition to the diagnostic arthroscopy, MRI is considered to be the gold standard of diagnosis of a meniscal root tear. Three different direct MRI signs for the diagnosis of a meniscus root tear have been described: Radial linear defect in the axial plane, vertical linear defect (truncation sign) in the coronal plane, and the so-called ghost meniscus sign in the sagittal plane. Meniscal extrusion is also considered to be an indirect sign of a root tear, but is less common in lateral root tears. During arthroscopy, the function of the meniscus root must be assessed by probing. However, visualization of the meniscal insertions is challenging. Refixation of the meniscal root can be performed using a transtibial pull-out suture, suture anchors, or side-to-side repair. Several short-term studies reported good clinical results after medial or lateral root repair. Nevertheless, MRI and second-look arthroscopy revealed high rates of incomplete or absent healing, especially for medial root tears. To date, most studies are case series with short-term follow-up and level IV evidence. Outerbridge grade 3 or 4 chondral lesions and varus malalignment of >5° were found to predict an inferior clinical outcome after medial meniscus root repair. Further research is needed to evaluate long-term results and to define evident criteria for meniscal root repair.
Aristoteli, Lina Panayiota; Willcox, Mark D P
2006-11-01
Pseudomonas aeruginosa is a pathogen gaining prevalence in contact lens-related corneal ulcers. Tear outflow protects the ocular surface, where high molecular weight tear glycoproteins bind bacteria for removal from the eye. The purpose of the present study was to identify glycoproteins in human tears involved in the adhesion of ocular P. aeruginosa isolates. Basal human tears were applied to a bacterial adhesion assay involving electrophoretic separation of tear components, transfer to nitrocellulose and incubation with biotin-labelled bacteria. Glycoproteins were further characterised using lectin profiling. The results showed large-dimension agarose gels were imperative for the detection of at least four glycoproteins with a migration >200 kDa, including species not previously identified. P. aeruginosa 6294 preferentially bound to a well-defined glycoprotein near the origin of the gel that, unlike other glycoproteins >200 kDa, reacted with Sambucus nigra lectin (sialic acid alpha2-6) but not WGA lectin (N-acetylglucosamine, sialic acid alpha2-3). Adhesion did not involve free biotin label or hydrophobic interactions. Also, the pre-incubation of separated tear glycoproteins with S. nigra lectin increased subsequent adhesion of 6294 to this tear glycoprotein. The less virulent Paer1 strain showed diffuse adhesion in the S. nigra-reactive region at the gel origin. In conclusion, an overlay adhesion assay was developed that identified slow-migrating sialylated glycoprotein species in human tears preferentially bound by P. aeruginosa ocular strains, and S. nigra lectin seemed to enhance the interaction. The study provides a basis for direct investigation of bacterial adhesion to glycoproteins with an apparent migration >200 kDa in tear fluid.
Cadogan, Angela; McNair, Peter; Laslett, Mark; Hing, Wayne; Taylor, Stephen
2013-01-01
Objectives: Rotator cuff tears are a common and disabling complaint. The early diagnosis of medium and large size rotator cuff tears can enhance the prognosis of the patient. The aim of this study was to identify clinical features with the strongest ability to accurately predict the presence of a medium, large or multitendon (MLM) rotator cuff tear in a primary care cohort. Methods: Participants were consecutively recruited from primary health care practices (n = 203). All participants underwent a standardized history and physical examination, followed by a standardized X-ray series and diagnostic ultrasound scan. Clinical features associated with the presence of a MLM rotator cuff tear were identified (P<0.200), a logistic multiple regression model was derived for identifying a MLM rotator cuff tear and thereafter diagnostic accuracy was calculated. Results: A MLM rotator cuff tear was identified in 24 participants (11.8%). Constant pain and a painful arc in abduction were the strongest predictors of a MLM tear (adjusted odds ratio 3.04 and 13.97 respectively). Combinations of ten history and physical examination variables demonstrated highest levels of sensitivity when five or fewer were positive [100%, 95% confidence interval (CI): 0.86–1.00; negative likelihood ratio: 0.00, 95% CI: 0.00–0.28], and highest specificity when eight or more were positive (0.91, 95% CI: 0.86–0.95; positive likelihood ratio 4.66, 95% CI: 2.34–8.74). Discussion: Combinations of patient history and physical examination findings were able to accurately detect the presence of a MLM rotator cuff tear. These findings may aid the primary care clinician in more efficient and accurate identification of rotator cuff tears that may require further investigation or orthopedic consultation. PMID:24421626
The potential of optical coherence tomography in meniscal tear characterization
NASA Astrophysics Data System (ADS)
Ling, Hang-yin; Guo, Shuguang; Thieman, Kelley M.; Wise, Brent T.; Pozzi, Antonio; Xie, Huikai; Horodyski, MaryBeth
2009-02-01
Meniscal tear is one of the most common knee injuries leading to pain and discomfort. Partial and total meniscectomies have been widely used to treat the avascular meniscal injuries in which tears do not heal spontaneously. However, the meniscectomies would cause an alteration of the tibiofemoral contact mechanics resulting in progressive osteoarthritis (OA). To mitigate the progression of OA, maximal preservation of meniscal tissue is recommended. The clinical challenge is deciding which meniscal tears are amenable to repair and which part of damaged tissues should be removed. Current diagnosis techniques such as arthroscopy and magnetic resonance imaging can provide macrostructural information of menisci, but the microstructural changes that occur prior to the observable meniscal tears cannot be identified by these techniques. Serving as a nondestructive optical biopsy, optical coherence tomography (OCT), a newly developed imaging modality, can provide high resolution, cross-sectional images of tissues and has been shown its capabilty in arthroscopic evaulation of articular cartilage. Our research was to demonstrate the potential of using OCT for nondestructive characterization of the histopathology of different types of meniscal tears from clinical cases in dogs, providing a fundamental understanding of the failure mechanism of meniscal tears. First, cross-sectional images of torn canine menisci obtained from the OCT and scanning electronic microscopy (SEM) were be compared. By studying the organization of collegan fibrils in torn menisci from the SEM images, the feasibility of using OCT to characterize the organization of collegan fibrils was elucidated. Moreover, the crack size of meniscal tears was quantatitively measured from the OCT images. Changes in the crack size of the tear may be useful for understanding the failure mechanism of meniscal tears.
Mayes, Susan; Ferris, April-Rose; Smith, Peter; Garnham, Andrew; Cook, Jill
2016-07-01
To compare the prevalence of acetabular labral tear in male and female professional ballet dancers with age-matched and sex-matched sporting participants and to determine the relationship to clinical findings and cartilage defects. Case-control study. Clinical and radiology practices. Forty-nine (98 hips) male and female professional ballet dancers (current and retired) with median age 30 years (range: 19-64 years) and 49 (98 hips) age-matched and sex-matched sporting participants. Group (ballet or sports), sex, age, hip cartilage defects, history of hip pain, Hip and Groin Outcome Score, passive hip internal rotation (IR), and external rotation range of movement (ROM). Labral tear identified with 3T magnetic resonance imaging (MRI). Labral tears were identified in 51% of all 196 hips. The prevalence did not differ significantly between the ballet and sporting participants (P = 0.41) or between sexes (P = 0.34). Labral tear was not significantly associated with clinical measures, such as pain and function scores or rotation ROM (P > 0.01 for all). Pain provocation test using IR at 90° of hip flexion had excellent specificity [96%, 95% confidence intervals (CIs), 0.77%-0.998%] but poor sensitivity (50%, 95% CI, 0.26%-0.74%) for identifying labral tear in participants reporting hip pain. Older age and cartilage defect presence were independently associated with an increased risk of labral tear (both P < 0.001). The prevalence of labral tear in male and female professional ballet dancers was similar to a sporting population. Labral tears were not associated with clinical findings but were related to cartilage defects, independent of aging. Caution is required when interpreting MRI findings as labral tear may not be the source of the ballet dancer's symptoms.
78 FR 22213 - Airworthiness Directives; Eurocopter France Helicopters
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-15
... float assemblies for any cuts, tears, punctures, or abrasion. Replace the cover if the internal... cuts, tears, punctures, or abrasion. If there is a cut, tear, puncture, or any abrasion, repair the...
Recent developments on dry eye disease treatment compounds
Colligris, Basilio; Alkozi, Hanan Awad; Pintor, Jesus
2013-01-01
Dry eye syndrome is a common tears and ocular surface multifactorial disease, described by changes in the ocular surface epithelia related to reduced tears quantity and ocular surface sensitivity, leading to inflammatory reaction. Managing the eye inflammation proved helpful to patients with dry eye disease and current treatment is based on the use of topically applied artificial tear products/lubricants, tear retention management, stimulation of tear secretion and using anti-inflammatory drugs. In this article we revise the corresponding literature and patents assembling the new treatment approaches of novel and future pharmaceutical compounds destined for the dry eye disease treatment. The most frequent categories of compounds presented are secretagogues and anti-inflammatory drugs. These compounds are the research outcome of novel therapeutic strategies designed to reduce key inflammatory pathways and restore healthy tear film. PMID:24526854
Bai, Yuqiang; Nichols, Jason J
2017-05-01
The thickness of tear film has been investigated under both invasive and non-invasive methods. While invasive methods are largely historical, more recent noninvasive methods are generally based on optical approaches that provide accurate, precise, and rapid measures. Optical microscopy, interferometry, and optical coherence tomography (OCT) have been developed to characterize the thickness of tear film or certain aspects of the tear film (e.g., the lipid layer). This review provides an in-depth overview on contemporary optical techniques used in studying the tear film, including both advantages and limitations of these approaches. It is anticipated that further developments of high-resolution OCT and other interferometric methods will enable a more accurate and precise measurement of the thickness of the tear film and its related dynamic properties. Copyright © 2017 Elsevier Ltd. All rights reserved.
Assessment, prevention and management of skin tears.
Benbow, Maureen
2017-04-28
Skin tears are common in older people. They are acute wounds that are at high risk of becoming complex, chronic wounds due to the interplay between the physiological changes in the skin and trauma from the external environment. Skin tears have been reported to have prevalence rates equal to, or greater than, those for pressure ulcers. A comprehensive risk assessment should include assessment of the individual's general health (chronic/critical disease, polypharmacy and cognitive, sensory and nutritional status); mobility (history of falls, impaired mobility, dependent activities of daily living, and mechanical trauma); and skin (extremes of age, fragile skin and previous skin tears). A recognised classification system should be used to identify and document skin tears and guide treatment decisions in line with local wound management protocols. Nurses and carers are in a prime position to prevent, assess and manage skin tears.
Interferometric characterization of tear film dynamics
NASA Astrophysics Data System (ADS)
Primeau, Brian Christopher
The anterior refracting surface of the eye is the thin tear film that forms on the surface of the cornea. When a contact lens is on worn, the tear film covers the contact lens as it would a bare cornea, and is affected by the contact lens material properties. Tear film irregularity can cause both discomfort and vision quality degradation. Under normal conditions, the tear film is less than 10 microns thick and the thickness and topography change in the time between blinks. In order to both better understand the tear film, and to characterize how contact lenses affect tear film behavior, two interferometers were designed and built to separately measure tear film behavior in vitro and in vivo. An in vitro method of characterizing dynamic fluid layers applied to contact lenses mounted on mechanical substrates has been developed using a phase-shifting Twyman-Green interferometer. This interferometer continuously measures light reflected from the surface of the fluid layer, allowing precision analysis of the dynamic fluid layer. Movies showing this fluid layer behavior can be generated. The fluid behavior on the contact lens surface is measured, allowing quantitative analysis beyond what typical contact angle or visual inspection methods provide. The in vivo interferometer is a similar system, with additional modules included to provide capability for human testing. This tear film measurement allows analysis beyond capabilities of typical fluorescein visual inspection or videokeratometry and provides better sensitivity and resolution than shearing interferometry methods.