Tear Osmolarity and Correlation With Ocular Surface Parameters in Patients With Dry Eye.
Mathews, Priya M; Karakus, Sezen; Agrawal, Devika; Hindman, Holly B; Ramulu, Pradeep Y; Akpek, Esen K
2017-11-01
To analyze the distribution of tear film osmolarity in patients with dry eye and its association with other ocular surface parameters. Tear osmolarity and other quantitative dry eye parameters were obtained from patients with 1) clinically significant dry eye (significant symptoms and ocular surface staining, n = 131), 2) symptoms-only dry eye (significant symptoms but no significant ocular surface staining, n = 52), and 3) controls (no significant symptoms or staining, n = 42). Tear osmolarity varied significantly across groups (P = 0.01), with patients with clinically significant dry eye having the highest tear osmolarity (312.0 ± 16.9 mOsm/L), control patients having the lowest tear osmolarity (305.6 ± 9.7 mOsm/L), and patients with symptoms-only dry eye falling in between (307.4 ± 5.6 mOsm/L). Patients with clinically significant dry eye also tended to have a greater intereye difference in osmolarity (12.0 ± 13.4) than did the individuals with symptoms-only dry eye (9.1 ± 12.4) and controls (9.0 ± 7.4) (P = 0.06). In multivariable regression models, higher tear osmolarity was associated with higher Ocular Surface Disease Index, discomfort subscore (P = 0.02), and higher corneal and conjunctival staining scores (P < 0.01 for both). Worse eye tear osmolarity was not correlated with the corresponding tear film breakup time or Schirmer test (P > 0.05 for both). Individuals with symptomatic dry eye that is not yet clinically significant seem to have higher and more variable osmolarity measurements than controls, potentially indicating that changes in osmolarity precede clinical findings.
Choi, Won; Lian, Cui; Ying, Li; Kim, Ga Eon; You, In Cheon; Park, Soo Hyun; Yoon, Kyung Chul
2016-09-01
To investigate the expression of lipid peroxidation markers in the tear film and ocular surface and their correlation with disease severity in patients with dry eye disease. The concentrations of hexanoyl-lysine (HEL), 4-hydroxy-2-nonenal (HNE), and malondialdehyde (MDA) were measured with enzyme-linked immunosorbent assays in tears obtained from 44 patients with non-Sjogren syndrome dry eye and 33 control subjects. The correlations between the marker levels and the tear film and ocular surface parameters, including tear film break-up time (BUT), Schirmer tear value, tear clearance rate, keratoepitheliopathy scores, corneal sensitivity, conjunctival goblet cell density, and symptom score, were analyzed. The expression of the lipid peroxidation markers HEL, 4-HNE, and MDA in the conjunctiva was evaluated using immunohistochemistry. The concentrations of HEL, 4-HNE, and MDA were 279.84 ± 69.98 nmol/L, 0.02 ± 0.01 μg/mL, and 3.80 ± 1.05 pmol/mg in control subjects and 283.21 ± 89.67 nmol/L (p = 0.97), 0.20 ± 0.03 μg/mL (p < 0.01), and 13.32 ± 4.03 pmol/mg (p < 0.01) in dry eye patients. 4-HNE and MDA levels significantly correlated with BUT, Schirmer tear value, tear clearance rate, keratoepitheliopathy scores, conjunctival goblet cell density, and symptom score (p < 0.05), whereas HEL levels did not correlate with these parameters. Staining intensities for 4-HNE and MDA increased in dry eye patients. The expression of late lipid peroxidation markers, 4-HNE and MDA, increases in the tear film and ocular surface of patients with dry eye. The levels correlate with various tear film and ocular surface parameters and may reflect the severity of dry eye disease.
Corneal Sensitivity in Tear Dysfunction and its Correlation with Clinical Parameters and Blink Rate
Rahman, Effie Z.; Lam, Peter K.; Chu, Chia-Kai; Moore, Quianta; Pflugfelder, Stephen C.
2015-01-01
Purpose To compare corneal sensitivity in tear dysfunction due to a variety of causes using contact and non-contact esthesiometers and to evaluate correlations between corneal sensitivity, blink rate and clinical parameters. Design Comparative observational case series. Methods Ten normal and 33 subjects with tear dysfunction [meibomian gland disease (n = 11), aqueous tear deficiency (n = 10) - without (n = 7) and with (n = 3) Sjögren syndrome (SS) and conjunctivochalasis (n = 12)] were evaluated. Corneal sensitivity was measured with Cochet-Bonnet and air jet esthesiometers and blink rate by electromyelography. Eye irritation symptoms, tear meniscus height, tear break-up time (TBUT), and corneal and conjunctival dye staining were measured. Between group means were compared and correlations calculated. Results Compared with control (Cochet-Bonnet 5.45 mm, air esthesiometer 3.62 mg), mean sensory thresholds were significantly higher in aqueous tear deficiency using either Cochet-Bonnet (3.6 mm; P = 0.003) or air (11.7 mg; P = 0.046) esthesiometers, but were not significantly different in the other groups. Reduced corneal sensitivity significantly correlated with more rapid TBUT and blink rate, and greater irritation and ocular surface dye staining with one or both esthesiometers. Mean blink rates were significantly higher in both aqueous tear deficiency and conjunctivochalasis compared with control. Among all subjects, blink rate positively correlated with ocular surface staining and irritation and inversely correlated with TBUT. Conclusion Amongst conditions causing tear dysfunction, reduced corneal sensitivity is associated with greater irritation, tear instability, ocular surface disease and blink rate. Rapid blinking is associated with worse ocular surface disease and tear stability. PMID:26255576
Evaluation of the Effects of Conjunctivochalasis Excision on Tear Stability and Contrast Sensitivity
Qiu, Weiqiang; Zhang, Mingzhou; Xu, Ting; Liu, Ziyuan; Lv, Huibin; Wang, Wei; Li, Xuemin
2016-01-01
Conjunctivochalasis (CCh) disrupts tear flow and damages tear film stability. This study sought to evaluate the tear stability and contrast sensitivity of patients with CCh on whom CCh excision was performed. The study included 39 eyes from 39 patients; all patients had eyes with grade 2 or 3 CCh, underwent CCh excision, and were evaluated before and three months after the surgery. The evaluated variables included the ocular surface disease index (OSDI), the tear break-up time (TBUT), corneal fluorescein staining, corneal surface irregularity, Schirmer’s I test, the tear meniscus area (TMA), and contrast sensitivity. A follow-up of three months was achieved in 36 eyes for 36 patients. All parameters improved significantly after surgery (p < 0.05), except Schirmer’s I test, thus suggesting that CCh excision is an effective method for reconstructing the lower tear meniscus and improving both tear film stability and corneal surface irregularity. The results further demonstrated a simultaneous increase in contrast sensitivity after surgery. PMID:27892479
Dogru, Murat; Ward, Samantha K; Wakamatsu, Tais; Ibrahim, Osama; Schnider, Cristina; Kojima, Takashi; Matsumoto, Yukihiro; Ogawa, Junko; Shimazaki, Jun; Tsubota, Kazuo
2011-04-01
To prospectively investigate the effects of 2 week senofilcon A contact lens (CL) daily wear on the functional visual acuity (VA), ocular surface and tear film. Seventeen right eyes of 17 senofilcon A CL wearers without any ocular or systemic diseases were examined before and 2 weeks after lens wear. Visual acuity measurements, tear evaporation rate, ELISA for tear cytokines, strip meniscometry, tear lipid layer interferometry, tear film break-up time (BUT), in vivo confocal microscopy, corneal sensitivity, ocular surface vital staining, Schirmer I test and brush cytology for MUC5AC mRNA expression were performed before and after CL wear. The best corrected Landolt VA, functional VA parameters, the mean lipid layer interferometry grades, tear evaporation rates, Schirmer test values, vital staining scores and in vivo confocal microscopy parameters did not show any significant differences after 2 weeks of CL wear. The tear film BUT showed a significant decrease together with a significant down regulation of MUC5 AC mRNA expression after CL wear. A statistically significant elevation in the mean tear interleukin (IL)-6 concentration was also observed after 2 weeks of CL wear. Two week senofilcon A daily CL wear seems to be associated with tear instability, a decrease in MUC5AC expression, and elevation of IL-6 in tears without significant alterations in epithelial damage scores or in the morphology or density of in vivo keratoconjunctival cells and nerves. Alterations associated with long term wear and patients with dry eye disease need to be studied in future trials. Copyright © 2010 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Wong, Aaron B C; Wang, Michael T M; Liu, Kevin; Prime, Zak J; Danesh-Meyer, Helen V; Craig, Jennifer P
2018-07-01
To assess tear film parameters, ocular surface characteristics, and dry eye symptomology in patients receiving topical anti-glaucoma medications. Thirty-three patients with a diagnosis of open angle glaucoma or ocular hypertension, receiving unilateral topical anti-glaucoma medication for at least 6 months, were recruited in a cross-sectional, investigator-masked, paired-eye comparison study. Tear film parameters, ocular surface characteristics, and dry eye symptomology of treated and fellow eyes were evaluated and compared. The mean ± SD age of the participants was 67 ± 12 years, and the mean ± SD treatment duration was 5.3 ± 4.4 years. Treated eyes had poorer non-invasive tear film breakup time (p = 0.03), tear film osmolarity (p = 0.04), bulbar conjunctival hyperaemia (p = 0.04), eyelid margin abnormality grade (p = 0.01), tear meniscus height (p = 0.03), and anaesthetised Schirmer value (p = 0.04) than fellow eyes. There were no significant differences in dry eye symptomology, meibomian gland assessments, and ocular surface staining between treated and fellow eyes (all p > 0.05). Adverse changes in tear film stability, tear osmolarity, conjunctival hyperaemia, and eyelid margins were observed in treated eyes. This suggests that inflammatory mechanisms may be implicated in the development of dry eye in patients receiving long term topical anti-glaucoma therapy. Copyright © 2018 Elsevier Inc. All rights reserved.
Effect of Ambient Temperature on the Human Tear Film.
Abusharha, Ali A; Pearce, E Ian; Fagehi, Raied
2016-09-01
During everyday life, the tear film is exposed to a wide range of ambient temperatures. This study aims to investigate the effect of ambient temperature on tear film physiology. A controlled environment chamber was used to create different ambient temperatures (5, 10, 15, 20, and 25°C) at a constant relative humidity of 40%. Subjects attended for two separate visits and were exposed to 25, 20, and 15°C at one visit and to 10 and 5°C at the other visit. The subjects were exposed to each room temperature for 10 min before investigating tear film parameters. The order of the visits was random. Tear physiology parameters assessed were tear evaporation rate, noninvasive tear break-up time (NITBUT), lipid layer thickness (LLT), and ocular surface temperature (OST). Each parameter was assessed under each condition. A threefold increase in tear evaporation rate was observed as ambient temperature increased to 25°C (P=0.00). The mean evaporation rate increased from 0.056 μL/min at 5°C to 0.17 μL/min at 25°C. The mean NITBUT increased from 7.31 sec at 5°C to 12.35 sec at 25°C (P=0.01). A significant change in LLT was also observed (P=0.00), LLT median ranged between 20 and 40 nm at 5 and 10°C and increased to 40 and 90 nm at 15, 20, and 25°C. Mean reduction of 4°C OST was observed as ambient temperature decreased from 25 to 5°C. Ambient temperature has a considerable effect on human tear film characteristics. Tear evaporation rate, tear LLT, tear stability, and OST were considerably affected by ambient temperature. Chronic exposure to low ambient temperature would likely result in symptoms of dry eye and ultimately ocular surface disorders.
Post-blink tear film dynamics in healthy and dry eyes during spontaneous blinking.
Szczesna-Iskander, Dorota H
2018-01-01
The aim was to investigate the dynamics of post-blink tear film leveling in natural blinking conditions (NBC) for healthy subjects and those diagnosed with dry eye syndrome (DES) and to relate this phase to the tear film surface quality (TFSQ) before the following blink. The study included 19 healthy persons and 10 with dry eye, grouped according to symptoms and signs observed during examination. Lateral shearing interferometry was used to examine TFSQ. Post-blink tear film dynamics was modeled by an exponential function, characterized by the decay parameter b, and a constant, describing the level of the stabilized TFSQ. Pre-next-natural-blink TFSQ dynamics was modeled with a linear trend, described by a parameter A. The post-blink tear film dynamics reached its plateau at a significantly (P = 0.006) lower level in the normal tear film group than in the dry eye group. The median exponential decay parameter b was statistically significantly higher for the control group than for the DES group, P = 0.026. The parameter b calculated for each interblink interval was significantly correlated with the corresponding parameter A (Spearman's R = 0.35; P < 0.001). Correlation between the median b and tear film fluorescein break-up time for each subject was also found (R = 0.41, P = 0.029). Significantly faster leveling of post-natural-blink tear film was observed in the group with DES than in healthy eyes. This dynamic was correlated with the pre-next-natural-blink TFSQ and tear film stability. The results of this pilot study support previous works that advocate the importance of polar lipids in the mechanism of tear film lipid spreading. Copyright © 2017 Elsevier Inc. All rights reserved.
Effects of Prolonged Reading on Dry Eye.
Karakus, Sezen; Agrawal, Devika; Hindman, Holly B; Henrich, Claudia; Ramulu, Pradeep Y; Akpek, Esen K
2018-04-25
To demonstrate the effects of prolonged silent reading on tear film and ocular surface parameters. Prospective, observational clinical study. A total of 177 patients with dry eye and 34 normal controls aged 50 years and older. After evaluating symptoms using the Ocular Surface Disease Index (OSDI) questionnaire, the following tests were performed in consecutive order: automated noninvasive tear break-up time (TBUT), surface asymmetry and regularity indices, Schirmer's testing without anesthesia, corneal staining using fluorescein, and conjunctival staining using lissamine green. The participants were then asked to read a 30-minute validated passage silently. The tests were repeated after the reading task. Changes in tear film and ocular surface parameters after reading. All parameters, with the exception of surface asymmetry index, worsened after the reading task in patients with dry eye and in controls. The worsening reached a statistical significance for corneal and conjunctival staining in the dry eye group (P < 0.001) and for corneal staining in the control group (P < 0.01). At baseline, OSDI scores correlated only with corneal and conjunctival staining scores (r = 0.19, P = 0.006 and r = 0.27, P < 0.001). Among postreading measurements, baseline OSDI scores correlated with TBUT (r = -0.15, P = 0.03) in addition to corneal and conjunctival staining (r = 0.25, P < 0.001 and r = 0.22, P = 0.001). Changes in TBUT and Schirmer's test correlated significantly with their respective baseline values (r = -0.61, P < 0.001 and r = -0.44, P < 0.001), indicating that the more unstable the tear film and the lower the aqueous tear secretion, the worse they became after the prolonged reading task. Worsening in corneal staining directly correlated with the baseline conjunctival staining (r = 0.17, P = 0.02) and surface regularity index (r = 0.21, P = 0.01). Evaluating tear film and ocular surface parameters at rest may miss clinical findings brought about by common everyday tasks such as reading, leading to discordance between patient-reported symptoms and clinician-observed signs. Quantifying dry eye after visually straining activities such as prolonged silent reading may help better understand patient symptomatology. Copyright © 2018 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Dry eye symptoms align more closely to non-ocular conditions than to tear film parameters.
Galor, Anat; Felix, Elizabeth R; Feuer, William; Shalabi, Nabeel; Martin, Eden R; Margolis, Todd P; Sarantopoulos, Constantine D; Levitt, Roy C
2015-08-01
To evaluate the relationship between dry eye symptoms, non-ocular conditions and tear film parameters. Cross-sectional study. The study population consisted of patients who were seen in the Miami Veterans Affairs eye clinic. Patients filled out standardised questionnaires assessing dry eye symptoms (dry eye questionnaire 5 (DEQ5) and ocular surface disease index (OSDI)), non-ocular pain, depression and post-traumatic stress disorder (PTSD), and also underwent measurement of tear film parameters. Correlations between dry eye symptoms and non-ocular conditions as compared with tear film parameters. 136 patients with a mean age of 65 (SD 11) years participated in the study. All correlations between the dry eye questionnaire scores (DEQ5 and OSDI) and (A) self-reported non-ocular pain measures (numerical rating scale and pain history), (B) depression and (C) PTSD were significant and moderate in strength (Pearson's coefficient 0.24 to 0.60, p<0.01 for all). All correlations between the dry eye questionnaires and tear film measures were weak (Pearson's coefficient -0.10 to 0.18) and most were not significant. Multivariable linear regression analyses revealed that PTSD and non-ocular pain more closely associated with dry eye symptoms than did tear film parameters. Specifically, non-ocular pain and PTSD accounted for approximately 36% of the variability in DEQ5 scores (R=0.60) and approximately 40% of variability in OSDI scores (R=0.64). Of note, none of the tear parameters remained significantly associated with dry eye symptoms in either model. Dry eye symptoms more closely align to non-ocular pain, depression and PTSD than to tear film parameters. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Liu, Ruixing; Rong, Bei; Tu, Ping; Tang, Yun; Song, Wenjing; Toyos, Rolando; Toyos, Melissa; Yan, Xiaoming
2017-11-01
To investigate the change from baseline of inflammatory markers in tears of dry eye disease (DED) subjects owing to meibomian gland dysfunction (MGD) after intense pulsed light (IPL) treatment and meibomian gland expression (MGE) compared to sham treatment, and the correlations with ocular surface parameters. Randomized, double-masked, controlled study. Those randomized into the active treatment arm received 3 consecutive treatments (14∼16 J/cm 2 ) approximately 4 weeks apart in the periocular region. Control eyes received 3 treatments in the same intervals of 0 J/cm 2 . Tear samples in all eyes were collected and analyzed at baseline, week 12, and/or week 4 for interleukin (IL)-17A, IL-6, and prostaglandin E2 (PGE2). The correlations between cytokines and ocular surface parameters were analyzed before and after IPL treatment. All of the inflammatory markers declined in value compared to baselines. IL-17A and IL-6 showed statistically significant decreases compared to sham treatment at each measured time point. PGE2 showed statistically significant decreases compared to sham at week 12. Results showed that the expressions of IL-17A and IL-6 correlated well with ocular surface parameters of the lower eyelid before IPL. The changed values of IL-6 and PGE2 in tears correlated with the changed values of partial ocular surface parameters after IPL treatment in study eyes, respectively. The study results suggest that IPL can significantly reduce inflammatory markers in tears of patients suffering with DED owing to MGD after IPL treatment. These findings indicate that IL-17A and IL-6 play roles in the pathogenesis of DED owing to MGD, and the reduction of the inflammatory factors is consistent with the improvement of partial clinical symptoms and signs. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Shigeyasu, Chika; Yamada, Masakazu; Akune, Yoko; Tsubota, Kazuo
2015-11-01
To evaluate the clinical efficacy of 3% diquafosol sodium ophthalmic solution for dry eye, and to analyze the concentration of tear proteins and mucin-like substances after the treatment. Fifty eyes of 25 patients with dry eye syndrome were prospectively enrolled. The patients were treated with diquafosol solution at a dose of 1 drop in each eye 6 times daily for 4 weeks. The parameters of clinical efficacy were tear osmolarity, tear breakup time (BUT), fluorescein staining scores for the cornea and conjunctiva, Schirmer test values, and subjective symptoms evaluated using the ocular surface disease index (OSDI). Tears collected with Schirmer test strips were analyzed by high-performance liquid chromatography, and the concentrations of the total protein and the 4 major tear proteins, namely, secretory IgA, lactoferrin, lipocalin-1, lysozyme, and N-acetyl-neuraminic acid (Neu5Ac), were measured. Neu5Ac is a major sialic acid, a marker of secretory mucins. The BUT, keratoconjunctival staining scores, and Schirmer test values were improved with statistical significance after the treatment with diquafosol solution, while changes in the other parameters, including tear osmolarity, corneal staining scores, and OSDI scores were not significant. The Neu5Ac concentration was significantly increased, which was not accompanied by changes in tear proteins. Topical application of diquafosol significantly improved the clinical parameters of the BUT, keratoconjunctival staining scores, and Schirmer test values and was accompanied by increased sialic acid content in the tears of patients with dry eye.
A mass and solute balance model for tear volume and osmolarity in the normal and the dry eye.
Gaffney, E A; Tiffany, J M; Yokoi, N; Bron, A J
2010-01-01
Tear hyperosmolarity is thought to play a key role in the mechanism of dry eye, a common symptomatic condition accompanied by visual disturbance, tear film instability, inflammation and damage to the ocular surface. We have constructed a model for the mass and solute balance of the tears, with parameter estimation based on extensive data from the literature which permits the influence of tear evaporation, lacrimal flux and blink rate on tear osmolarity to be explored. In particular the nature of compensatory events has been estimated in aqueous-deficient (ADDE) and evaporative (EDE) dry eye. The model reproduces observed osmolarities of the tear meniscus for the healthy eye and predicts a higher concentration in the tear film than meniscus in normal and dry eye states. The differential is small in the normal eye, but is significantly increased in dry eye, especially for the simultaneous presence of high meniscus concentration and low meniscus radius. This may influence the interpretation of osmolarity values obtained from meniscus samples since they need not fully reflect potential damage to the ocular surface caused by tear film hyperosmolarity. Interrogation of the model suggests that increases in blink rate may play a limited role in compensating for a rise in tear osmolarity in ADDE but that an increase in lacrimal flux, together with an increase in blink rate, may delay the development of hyperosmolarity in EDE. Nonetheless, it is predicted that tear osmolarity may rise to much higher levels in EDE than ADDE before the onset of tear film breakup, in the absence of events at the ocular surface which would independently compromise tear film stability. Differences in the predicted responses of the pre-ocular tears in ADDE compared to EDE or hybrid disease to defined conditions suggest that no single, empirically-accessible variable can act as a surrogate for tear film concentration and the potential for ocular surface damage. This emphasises the need to measure and integrate multiple diagnostic indicators to determine outcomes and prognosis. Modelling predictions in addition show that further studies concerning the possibility of a high lacrimal flux phenotype in EDE are likely to be profitable.
Szyperski, Piotr D
2018-06-01
The purpose of this research was to evaluate the applicability of the fractal dimension (FD) estimators to assess lateral shearing interferometric (LSI) measurements of tear film surface quality. Retrospective recordings of tear film measured with LSI were used: 69 from healthy subjects and 41 from patients diagnosed with dry eye syndrome. Five surface quality descriptors were considered, four based on FD and a previously reported descriptor operating in a spatial frequency domain (M 2 ), presenting temporal kinetics of post-blink tear film. A set of 12 regression parameters has been extracted and analyzed for classification purposes. The classifiers are assessed in terms of receiver operating characteristics and areas under their curves (AUC). Also, the computational loads are estimated. The maximum AUC of 82.4% was achieved for M 2 , closely followed by the binary box-counting (BBC) FD estimator with AUC=78.6%. For all descriptors, statistically significant differences between the subject groups were found (p<0.05). The BBC FD estimator was characterized with the highest empirical computational efficiency that was about 30% faster than that of M 2 , while that based on the differential box-counting exhibited the lowest efficiency (4.5 times slower than the best one). Concluding, FD estimators can be utilized for quantitative assessment of tear film kinetics. They provide a viable alternative to previously used spectral counter parameters, and at the same time allow higher computational efficiency.
Dynamics of a pre-lens tear film after a blink: Model, evolution, and rupture
NASA Astrophysics Data System (ADS)
Usha, R.; Anjalaiah, Sanyasiraju, Y. V. S. S.
2013-11-01
A mathematical model is developed to investigate the dynamics and rupture of a pre-lens tear film on a contact lens. The contact lens is modeled as a saturated porous medium of constant, finite thickness and is described by the Darcy-Brinkman equations with stress-jump condition at the interface. The model incorporates the influence of capillarity, gravitational drainage, contact lens properties such as the permeability, the porosity, and the thickness of the contact lens on the evolution and rupture of a pre-lens tear film, when the eyelid has opened after a blink. Two models are derived for the evolution of a pre-lens tear film thickness using lubrication theory and are solved numerically; the first uses shear-free surface condition and the second, the tangentially immobile free surface condition. The results reveal that life span of a pre-lens tear film is longer on a thinner contact lens for all values of permeability and porosity parameter considered. An increase in permeability of contact lens, porosity or stress-jump parameter increases the rate of thinning of the film and advances the rupture time. The viscous-viscous interaction between the porous contact lens and the pre-lens tear film increases the resistance offered by the frictional forces to the rate of thinning of pre-lens tear film. This slows down the thinning process and hence delays the rupture of the film as compared to that predicted by the models of Nong and Anderson [SIAM. J. Appl. Math. 70, 2771-2795 (2010)] derived in the framework of Darcy model.
Physical Changes in Human Meibum with Age as Measured by Infrared Spectroscopy
Borchman, Douglas; Foulks, Gary N.; Yappert, Marta C.; Kakar, Shelly; Podoll, Nathan; Rychwalski, Paul; Schwietz, Eric
2010-01-01
Both lipids and mucins contribute to the stability of the tear film and lipids may inhibit tears from evaporating. Younger people have lower lipid viscosity, higher lipid volume, and a lower rate of tear evaporation. Since age-related changes in human meibum composition and conformation have never been investigated, as a basis for the study of lipid-associated changes with meibomian gland dysfunction, we used the power of infrared spectroscopy to characterize hydrocarbon chain conformation and packing in meibum from humans without dry eye symptoms in relation to age and sex. Meibum from normal human donors ranging in age from 3 to 88 years was studied. Meibum phase transitions were quantified by fitting them to a 4-parameter 2-state sigmoidal equation. Human meibum order and phase transition temperatures decrease with age and this trend may be attributed to lipid compositional changes. If meibum has the same thermodynamic properties on the surface of the tears as it does on the lid margin, a decrease in lipid-lipid interaction strength with increasing age could decrease the stability of tears since lipid-lipid interactions on the tear surface must be broken for the tear film to break up. This study also serves as a foundation to examine meibum conformational differences in meibum from people with meibomian gland dysfunction. PMID:20160464
Borrelli, Maria; Schröder, Christina; Dart, John K G; Collin, John Richard O; Sieg, Peter; Cree, Ian A; Matheson, Melville A; Tiffany, John M; Proctor, Gordon; van Best, Jaap; Hyde, Nick; Geerling, Gerd
2010-12-01
To evaluate the long-term results of autologous submandibular gland transplantation in eyes with cicatrizing conjunctivitis and to determine biomechanical and biochemical features of the resulting salivary tear film. Prospective, observational case series. Fifteen eyes with cicatrizing conjunctivitis with a viable autologous submandibular gland transplantation were compared with 10 eyes with cicatrizing conjunctivitis and a failed submandibular gland transplantation or no submandibular gland transplantation. Best-corrected visual acuity, frequency of tear substitute instillation, severity of dry eye discomfort, lid margin erythema, conjunctival hyperemia, corneal epithelial edema, tear film break-up time, Schirmer test results, and corneal fluorescein and conjunctival Rose Bengal staining were evaluated. In a subgroup central corneal thickness and sensitivity, corneal epithelial barrier function, conjunctival and lid margin flora, and conjunctival impression cytologic analysis results were evaluated. In 3 patients, preoperative and postoperative tear samples were analyzed for viscosity, surface tension, and presence of mucins. Submandibular gland autotransplantation resulted in long-term improvement of subjective, objective, and some ocular surface parameters. Salivary mucins were detectable in salivary tears after submandibular gland transplantation. The viscosity of salivary tears was more similar to normal saliva and the surface tension was intermediate between the 2 original secretions. Submandibular gland autotransplantation provides long-term relief from pain and reduces the need for frequent installation of lubricants. Copyright © 2010 Elsevier Inc. All rights reserved.
Dry eye in vitamin D deficiency: more than an incidental association.
Yildirim, Pelin; Garip, Yeşim; Karci, Ayse Aslihan; Guler, Tuba
2016-01-01
The aim of this article is two-fold: (i) to demonstrate the relation between vitamin D deficiency and dry eye and impaired tear function; and (ii) to investigate the possible associations among clinical parameters of hypovitaminosis D with dry eye parameters. Fifty premenopausal women with vitamin D deficiency (serum vitamin D levels < 20 ng/mL) and 48 controls were included. Participants were assessed by Schirmer's test, tear break-up time test (TBUT), ocular surface disease index (OSDI), Stanford Health Assessment Questionnaire (HAQ), fatigue severity scale (FSS), and visual analogue scale-pain (VAS-pain). Lower scores in Schirmer's test and TBUT, and higher in OSDI were detected in patients with vitamin D deficiency than in controls (P < 0.05). FSS was negatively correlated with Schirmer's test (r = -0,29; P = 0.038) and TBUT scores (r = -0,43; P = 0.002); VAS-pain was negatively correlated with TBUT scores (r = -0.32; P = 0.023). HAQ scores showed no significant correlation with dry eye parameters (P > 0.05). Vitamin D level was negatively correlated with OSDI (r = -0.49; P < 0.001), and positively with Schirmer's test (r = 0.45; P = 0.001) and TBUT scores (r = 0.30; P = 0.029). Dry eye and impaired tear function in patients with vitamin D deficiency may indicate a protective role of vitamin D in the development of dry eye, probably by enhancing tear film parameters and reducing ocular surface inflammation. Patients with vitamin D deficiency should be evaluated for dry eye syndromes. © 2015 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.
Shigeyasu, Chika; Yamada, Masakazu; Akune, Yoko; Fukui, Masaki
2017-12-13
To evaluate the changes in ocular surface mucins with 2%rebamipide ophthalmic suspension treatment in soft contact lens (SCL) wearers. Rebamipide suspension is a mucin secretagogue approved for the treatment of dry eye syndrome in Japan. In this study, the fluorescence intensity of wheat germ agglutinin conjugate of fluorescein (F-WGA) was used as a marker of membrane-associated mucins, and sialic acid concentration in tear fluids as a marker of secreted mucins. Thirty-two eyes of 16 SCL wearers with discomfort were treated with rebamipide suspension at a dose of one drop in each eye four times daily for two weeks. The parameters of clinical efficacy were tear break-up time, fluorescein staining scores for the cornea and conjunctiva, and Schirmer test values. Fluorescence intensities in the central cornea were measured by fluorophotometry after the application of 5% F-WGA solution. Tears collected by Schirmer test strips were analyzed by high-performance liquid chromatography, and the concentrations of sialic acid, total protein, and the four major tear proteins, namely secretory IgA, lactoferrin, lipocalin-1, and lysozyme were measured. Significant increases in F-WGA fluorescence intensities (p < 0.005) were seen in the corneal surfaces. Sialic acid concentrations increased over time; however, the differences were not statistically significant. Except for a slight increase in kerato-conjunctival staining scores (p < 0.05) and secretory IgA (p < 0.05), no other significant differences were seen among clinical parameters or tear proteins. Topical application of rebamipide suspension significantly increased F-WGA intensity, a marker of membrane-associated mucins in SCL wearers. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Assessment of tear osmolarity and other dry eye parameters in post-LASIK eyes.
Hassan, Ziad; Szalai, Eszter; Berta, Andras; Modis, Laszlo; Nemeth, Gabor
2013-07-01
To assess the tear osmolarity using the TearLab device after laser in situ keratomileusis (LASIK) and to compare the values with those obtained by traditional tear film tests before and after the procedure. Thirty eyes of 15 refractive surgery candidates (5 men and 10 women of mean age: 30.55 ± 11.79 years) were examined. Using a special questionnaire (Ocular Surface Disease Index), subjective dry eye complaints were evaluated, and then, the tear osmolarity was measured with the TearLab system (TearLab Corporation) and conventional dry eye tests were carried out. Examinations were performed preoperatively and at 1, 30, and 60 days after the surgery. The mean value of tear osmolarity was 303.62 ± 12.29 mOsm/L before the surgery and 303.58 ± 20.14 mOsm/L at 60 days after the treatment (P = 0.69). Mean lid parallel conjunctival folds value was 0.68 ± 0.68 before the procedure and 0.58 ± 0.65 subsequent to surgery (P = 0.25). Meibomian gland dysfunction was not detected. No significant deviation was observed in the values of Schirmer test, corneal staining, tear break-up time, and lid parallel conjunctival folds when compared with postoperatively obtained values during the follow-up period (P > 0.05). During LASIK flap creation, intact corneal innervation is damaged, and the ocular surface lacrimal functional unit can be impaired. In our study, no abnormal dry eye test results were observed before or after the procedure. Based on our results, LASIK treatment is safe for dry eye involving the administration of adequate artificial tears for a minimum of 3 months.
Eissa, Iman M; Khalil, Noha M; El-Gendy, Heba A
2016-01-01
Purpose. To assess the tear film quantity and correlate it with the quality and stability of the tear film in diabetics and compare them to age matched controls. Introduction. Diabetes affects tear film parameters in multiple ways. Poor metabolic control and neuropathy are postulated factors. To further understand how diabetes affects tear film parameters this study was conducted. Subjects and Methods. Tear meniscus height was measured by anterior segment OCT, along with tear thinning time, a subtype of noninvasive tear break-up time, and blinking rate per minute which were all recorded for 22 diabetic patients. Correlations between these tear film parameters were studied and then compared to 16 age matched controls. Results. A statistically significant difference was found in blinking rate between the diabetic and the control group (P = 0.002), with higher blinking rate among diabetics. All tear film parameters were negatively correlated with duration of diabetes. A positive correlation was found between tear film volume and stability. Conclusion. Diabetes affects the tear film in various ways. Diabetics should be examined for dry eye signs even in absence of symptoms which may be masked by associated neuropathy. Duration of diabetes has an impact on tear film status.
Craig, Jennifer P; Wang, Michael T M; Ganesalingam, Kalaivarny; Rupenthal, Ilva D; Swift, Simon; Loh, Chee Seang; Te Weehi, Leah; Cheung, Isabella M Y; Watters, Grant A
2017-01-01
Objective To assess the clinical safety and tolerability of a novel MGO Manuka Honey microemulsion (MHME) eye cream for the management of blepharitis in human subjects. Methods and analysis Twenty-five healthy subjects were enrolled in a prospective, randomised, paired-eye, investigator-masked trial. The MHME eye cream (Manuka Health New Zealand) was applied to the closed eyelids of one eye (randomised) overnight for 2 weeks. LogMAR visual acuity, eyelid irritation symptoms, ocular surface characteristics and tear film parameters were assessed at baseline, day 7 and day 14. Expression of markers of ocular surface inflammation (matrix metalloproteinase-9 and interleukin-6) and goblet cell function (MUC5AC) were quantified using impression cytology at baseline and day 14. Results There were no significant changes in visual acuity, eyelid irritation symptoms, ocular surface characteristics, tear film parameters and inflammatory marker expression during the 2-week treatment period in treated and control eyes (all p>0.05), and measurements did not differ significantly between eyes (all p>0.05). No major adverse events were reported. Two subjects experienced transient ocular stinging, presumably due to migration of the product into the eye, which resolved following aqueous irrigation. Conclusion The MHME eye cream application was found to be well tolerated in healthy human subjects and was not associated with changes in visual acuity, ocular surface characteristics, tear film parameters, expression of markers of inflammation or goblet cell function. The findings support future clinical efficacy trials in patients with blepharitis. Trial registration number ACTRN12616000540415 PMID:29354710
Kaido, Minako; Ishida, Reiko; Dogru, Murat; Tsubota, Kazuo
2011-09-01
To investigate the relation of functional visual acuity (FVA) measurements with dry eye test parameters and to compare the testing methods with and without blink suppression and anesthetic instillation. A prospective comparative case series. Thirty right eyes of 30 dry eye patients and 25 right eyes of 25 normal subjects seen at Keio University School of Medicine, Department of Ophthalmology were studied. FVA testing was performed using a FVA measurement system with two different approaches, one in which measurements were made under natural blinking conditions without topical anesthesia (FVA-N) and the other in which the measurements were made under the blink suppression condition with topical anesthetic eye drops (FVA-BS). Tear function examinations, such as the Schirmer test, tear film break-up time, and fluorescein and Rose Bengal vital staining as ocular surface evaluation, were performed. The mean logMAR FVA-N scores and logMAR Landolt visual acuity scores were significantly lower in the dry eye subjects than in the healthy controls (p < 0.05), while there were no statistical differences between the logMAR FVA-BS scores of the dry eye subjects and those of the healthy controls. There was a significant correlation between the logMAR Landolt visual acuities and the logMAR FVA-N and logMAR FVA-BS scores. The FVA-N scores correlated significantly with tear quantities, tear stability and, especially, the ocular surface vital staining scores. FVA measurements performed under natural blinking significantly reflected the tear functions and ocular surface status of the eye and would appear to be a reliable method of FVA testing. FVA measurement is also an accurate predictor of dry eye status.
Conversion of the dominantly ideal perturbations into a tearing mode after a sawtooth crash
DOE Office of Scientific and Technical Information (OSTI.GOV)
Igochine, V., E-mail: valentin.igochine@ipp.mpg.de; Gude, A.; Günter, S.
2014-11-15
Forced magnetic reconnection is a topic of common interest in astrophysics, space science, and magnetic fusion research. The tearing mode formation process after sawtooth crashes implies the existence of this type of magnetic reconnection and is investigated in great detail in the ASDEX Upgrade tokamak. The sawtooth crash provides a fast relaxation of the core plasma temperature and can trigger a tearing mode at a neighbouring resonant surface. It is demonstrated for the first time that the sawtooth crash leads to a dominantly ideal kink mode formation at the resonant surface immediately after the sawtooth crash. Local measurements show thatmore » this kink mode transforms into a tearing mode on a much longer timescale (10{sup −3}s−10{sup −2}s) than the sawtooth crash itself (10{sup −4}s). The ideal kink mode formed after the sawtooth crash provides the driving force for magnetic reconnection and its amplitude is one of the critical parameters for the length of the transition phase from a ideal into an resistive mode. Nonlinear two fluid MHD simulations confirm these observations.« less
Tear geometry at active STEPs: an analogue model approach
NASA Astrophysics Data System (ADS)
Broerse, Taco; Sokoutis, Dimitrios; Willingshofer, Ernst; Govers, Rob
2017-04-01
At the lateral end of a subduction zone, tearing of lithosphere is the result of subduction of oceanic lithosphere while adjacent buoyant continental lithosphere stays at the surface. The location of lithospheric tearing is called a Subduction-Transform-Edge-Propagator (STEP), which continuously extends the plate boundary between overriding plate and continental lithosphere. One of our areas of interest is the southern Caribbean where Atlantic lithosphere subducts below the Caribbean plate. Mantle tomography suggests a clear southern edge of the Lesser Antilles slab, which makes the boundary between the Caribbean and South America a clear STEP candidate. At the surface, the San Sebastián/El Pilar fault zone forms the plate boundary between the Caribbean and South America and the active STEP is located near Trinidad. For the deeper part of the damage/shear zone, some information is available from a recent 3D gravity study: significant lateral variability in densities of the lithospheric mantle to the south of the STEP fault zone. The low-density zone may result from higher sub-crustal temperatures, such as would arise from an asthenospheric window resulting from detachment. Interpreted in this way, the mantle part of the damage zone may be 200-250 km wide. So, while the location of the plate boundary at the surface is relatively well resolved, little is known about the deeper continuation of the active STEP in the mantle lithosphere. We study the evolution of the tearing process at a STEP using analogue models. In our models we use silicone putty (lithosphere) and glucose (asthenosphere). Solely gravitational forces resulting from density differences between oceanic lithosphere and asthenosphere drive our model. Lithospheric tearing commences after subduction has initiated. The geometry of the tear varies with the rheology of the lithosphere and asthenosphere, particularly Newtonian versus power-law. We investigate the dependence on model parameters of the width of the tearing zone and the depth at which tearing occurs.
Heynen, Miriam; Kay, Lise M.M.; Dominici, Claudia Yvette; Khan, Warda; Ng, Wendy W.S.; Jones, Lyndon
2011-01-01
Purpose To characterize various properties of a physiologically-relevant artificial tear solution (ATS) containing a range of tear film components within a complex salt solution, and to measure contact lens parameters and lipid deposition of a variety of contact lens materials after incubation in this ATS. Methods A complex ATS was developed that contains a range of salts, proteins, lipids, mucin, and other tear film constituents in tear-film relevant concentrations. This ATS was tested to confirm that its pH, osmolality, surface tension, and homogeneity are similar to human tears and remain so throughout the material incubation process, for up to 4 weeks. To confirm that silicone hydrogel and conventional hydrogel contact lens materials do not alter in physical characteristics beyond what is allowed by the International Organization for Standardization (ISO) 18369–2. The diameter, center thickness, and calculated base curve were measured for five different lens materials directly out of the blister pack, after a rinse in saline and then following a two week incubation in the modified ATS. To test the ATS and the effect of its composition on lipid deposition, two lens materials were incubated in the ATS and a modified version for several time points. Both ATS solutions contained trace amounts of carbon-14 cholesterol and phosphatidylcholine, such that deposition of these specific lipids could be quantified using standard methods. Results This ATS is a complex mixture that remains stable at physiologically relevant pH (7.3–7.6), osmolality (304–306 mmol/kg), surface tension (40–46 dynes/cm) and homogeneity over an incubation period of three weeks or more. The physical parameters of the lenses tested showed no changes beyond that allowed by the ISO guidelines. Incubations with the ATS found that balafilcon A lenses deposit significantly more cholesterol and phosphatidylcholine than omafilcon A lenses (p<0.05) and that removing lactoferrin and immunoglobulin G from the ATS can significantly decrease the mass of lipid deposited. Conclusions This paper describes a novel complex artificial tear solution specially designed for in-vial incubation of contact lens materials. This solution was stable and did not adversely affect the physical parameters of the soft contact lenses incubated within it and showed that lipid deposition was responsive to changes in ATS composition. PMID:22219635
Ahn, Somin; Eom, Youngsub; Kang, Boram; Park, Jungboung; Lee, Hyung Keun; Kim, Hyo Myung; Song, Jong Suk
2018-05-01
To evaluate the effects of menthol-containing artificial tears on tear stimulation and ocular surface integrity in normal and dry eye rat models. A total of 54 male Lewis rats were used. The levels of tear secretion and tear MUC5AC concentrations were compared between the menthol-containing artificial tear-treated group (menthol group) and the vehicle-treated group (vehicle group). The groups were compared after a single instillation to evaluate the immediate effects, and after repeated instillation (five times a day for 5 days) to evaluate the longer-term effects. Tear lactate dehydrogenase (LDH) activity was measured to evaluate eye drop instillation-induced ocular surface damage. The effects of menthol-containing artificial tears were also evaluated in a dry eye rat model. After a single instillation of menthol-containing artificial tears, tear secretion increased from 4.37 (±0.75) mm at baseline to 7.37 (±1.60) mm. However, after repeated instillations, the effects of tear stimulation decreased. The tear MUC5AC concentration was significantly lower in the menthol group than in the vehicle group after a single instillation, but not after repeated instillation. However, the tear LDH concentration was significantly increased in the menthol group after repeated instillation. In the dry eye rat model, the extent of menthol-induced tear stimulation was reduced. Menthol-containing artificial tears increased tear secretion, but lowered the tear MUC5AC concentration. Menthol-induced tear stimulation was reduced after repeated instillation for 5 days and in the dry eye rat model. Conversely, repeated instillation of menthol-induced ocular surface damage, resulting in increased tear LDH activity.
Su, Tai Yuan; Ho, Wei Ting; Lu, Chien Yi; Chang, Shu Wen; Chiang, Huihua Kenny
2015-04-01
To report the use of a thermographer for measuring ocular surface temperature, and to evaluate the correlation among the obtained temperature difference values (TDVs) and dry eye parameters (tear meniscus height (TMH); Schirmer's test results; fluorescent tear breakup time (FTBUT)). Forty-three participants (age 40.2±14.7 years; range 21-67 years) from Far Eastern Memorial Hospital, Taiwan were recruited for the study. The surface temperature was measured at the centre of the ocular surface for 4 s after blinking. TDV was defined as the change in corneal surface temperature relative to that of the preceding eye opening, where TDV01, TDV02, TDV03, and TDV04 represent the values obtained 1, 2, 3, and 4 s after blinking, respectively. Anterior segment optical coherence tomography (AS-OCT) was employed to measure the lower TMH. Schirmer's test with topical anaesthetic was conducted to measure the basal tear secretion. The FTBUT was recorded using a digital camera. TDV measurement exhibited high reliability (intraclass correlation coefficient=0.91). TDV03 exhibited the highest significance and strongest positive correlation with the TMH (r=0.52, p=0.0003) and Schirmer's test value (r=0.39, p=0.008), whereas the TDV03-FTBUT correlation was non-significant. Age correlated negatively and significantly with the TDV (r= -0.35, p=0.021), TMH (r= -0.33, p=0.031), and Schirmer's test value (r= -0.31, p=0.044). TDV03 remained significantly correlated with the TMH and Schirmer's test value after adjustment for age. The thermographer was effective in capturing temperature changes in the ocular surface. The temperature difference 3 s after blinking appears to be correlated with lower TMH and Schirmer test values. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
[Factors influencing the measurement of tear film lipid layer thickness with interferometry].
Finis, D; Pischel, N; Borrelli, M; Schrader, S; Geerling, G
2014-06-01
The quantitative measurement of the tear film lipid layer thickness is a relatively new and promising method. However, so far it has not been investigated whether there is a diurnal or a day to day variability and whether certain factors are confounding the measurement of the lipid layer thickness. In three different experimental settings, 10 subjects without known sicca syndrome were examined at three different time points on one day, on three different days and before and after therapeutic expression of the Meibomian glands. As a comparison, the parameters tear film break-up time, tear meniscus height, diagnostic expression of the Meibomian glands and subjective symptoms, determined using the OSDI (ocular surface disease index) questionnaire, were measured. The results of the study showed a smaller variation of the lipid layer thickness measurements during the day and from day to day compared to the tear film break-up time. The expression of the Meibomian glands significantly increased the lipid layer thickness. There was a correlation between the baseline values of tear film break-up time and the lipid layer thickness. Our data showed that the lipid layer thickness as measured with the Lipiview® interferometer appears to be a relatively constant parameter over time. In addition, the expression of the Meibomian glands could be identified as a potential confounding factor. In this study we included only healthy subjects without known sicca syndrome. For the future our findings need to be validated in dry eye patients. Georg Thieme Verlag KG Stuttgart · New York.
Interferometer for measuring the dynamic surface topography of a human tear film
NASA Astrophysics Data System (ADS)
Primeau, Brian C.; Greivenkamp, John E.
2012-03-01
The anterior refracting surface of the eye is the thin tear film that forms on the surface of the cornea. Following a blink, the tear film quickly smoothes and starts to become irregular after 10 seconds. This irregularity can affect comfort and vision quality. An in vivo method of characterizing dynamic tear films has been designed based upon a near-infrared phase-shifting interferometer. This interferometer continuously measures light reflected from the tear film, allowing sub-micron analysis of the dynamic surface topography. Movies showing the tear film behavior can be generated along with quantitative metrics describing changes in the tear film surface. This tear film measurement allows analysis beyond capabilities of typical fluorescein visual inspection or corneal topography and provides better sensitivity and resolution than shearing interferometry methods. The interferometer design is capable of identifying features in the tear film much less than a micron in height with a spatial resolution of about ten microns over a 6 mm diameter. This paper presents the design of the tear film interferometer along with the considerations that must be taken when designing an interferometer for on-eye diagnostics. Discussions include eye movement, design of null optics for a range of ocular geometries, and laser emission limits for on-eye interferometry.
Contreras-Ruiz, L; Zorzi, G K; Hileeto, D; López-García, A; Calonge, M; Seijo, B; Sánchez, A; Diebold, Y
2013-05-01
MUC5AC is a glycoprotein with gel-forming properties, whose altered expression has been implicated in the pathogenesis of dry eye disease. The aim of our study was to achieve an efficient in vivo transfection of MUC5AC, restore its normal levels in an inflamed ocular surface and determine whether restored MUC5AC levels improve ocular surface inflammation. Cationized gelatin-based nanoparticles (NPs) loaded with a plasmid coding a modified MUC5AC protein (pMUC5AC) were instilled in healthy and experimental dry eye (EDE) mice. MUC5AC expression, clinical signs, corneal fluorescein staining and tear production were evaluated. Ocular specimens were processed for histopathologic evaluation, including goblet cell count and CD4 immunostaining. Neither ocular discomfort nor irritation was observed in vivo after NP treatment. Expression of modified MUC5AC was significantly higher in ocular surface tissue of pMUC5AC-NP-treated animals than that of controls. In healthy mice, pMUC5AC-NPs had no effect on fluorescein staining or tear production. In EDE mice, both parameters significantly improved after pMUC5AC-NP treatment. Anterior eye segment of treated mice showed normal architecture and morphology with lack of remarkable inflammatory changes, and a decrease in CD4+ T-cell infiltration. Thus, pMUC5AC-NPs were well tolerated and able to induce the expression of modified MUC5A in ocular surface tissue, leading to reduction of the inflammation and, consequently improving the associated clinical parameters, such as tear production and fluorescein staining. These results identify a potential application of pMUC5AC-NPs as a new therapeutic modality for the treatment of dry eye disease.
Tear clearance implications for ocular surface health.
de Paiva, Cintia Sade; Pflugfelder, Stephen C
2004-03-01
Tear clearance/turnover provides a global assessment of the function of the lacrimal functional unit and of tear exchange on the ocular surface. It is an indirect measure of dry eye induced inflammation on the ocular surface. It shows better correlation with the severity of ocular irritation symptoms and corneal epithelial disease in dry eye than the Schirmer 1 test. Delayed tear clearance may prove to be the best measure for identifying patients with tear film disorders who may respond to anti-inflammatory therapy.
Liu, Qingyu; Liu, Junling; Ren, Chengda; Cai, Wenting; Wei, Qingquan; Song, Yi; Yu, Jing
2017-01-01
The purpose of this study was to investigate whether acupuncture is effective at treating dry eye disease among postmenopausal women and to identify the possible mechanisms. Twenty-eight postmenopausal women with dry eye disease were randomly divided into two groups: an acupuncture plus artificial tears (AC + AT) group and an artificial tears (AT) only group. After baseline examination of clinical parameters and tear sample collection, each patient received the designated modality of topical therapy for 2 months. Post-treatment documentation of clinical parameters was recorded, and tear samples were collected. Tear samples from the AC + AT group were subjected to two-dimensional nano-liquid chromatography coupled with tandem mass spectrometry (2D nano-LC-MS/MS). Western blot analysis was also performed on tear samples from both groups. After treatment, the Ocular Surface Disease Index scores, symptom assessment scores, scores of sign assessment, and tear break-up time were significantly improved in both groups ( P =0.000). Symptom assessment scores were significantly improved in the AC + AT group ( P =0.000) compared with the AT group. 2D nano-LC-MS/MS identified 2,411 proteins, among which 142 were downregulated and 169 were upregulated. After combined AC + AT treatment, the abundance of secreted proteins was increased, whereas that of cytoplasmic proteins decreased (Pearson's χ 2 test, P =0.000, P =0.000, respectively). Proteins involved in immunity and regulation were also more abundant (Pearson's χ 2 test, P =0.040, P =0.016, respectively), while components and proliferation-related proteins were downregulated (Pearson's χ 2 test, P =0.003, P =0.011, respectively). AC + AT treatment increased protein synthesis and secretion, and improved clinical symptoms. These results indicate that acupuncture may be a complimentary therapy for treating postmenopausal dry eye disease.
The brilliant beauty of the eye: light reflex from the cornea and tear film.
Goto, Eiki
2006-12-01
Light reflex from the cornea and tear film as contributors to beautiful eyes ("eye sparkling") are reviewed. A systematic literature review was conducted using "Purkinje-Sanson image," "corneal light reflex," "corneal topography," "corneal wavefront aberration," and "tear interference image" as search terms. Articles on corneal surface regularity and stability and tear interferometry of the precorneal tear lipid layer were reviewed. PS-1 image, that is light reflex from the cornea and tear film, is widely used in practical ophthalmic examination. To achieve a brilliant beauty of the eye ("eye sparkling"), it is important that the tear film (aqueous layer) surface is smooth and stable with adequate tear volume and that the tear lipid layer is present in adequate thickness.
Demiryay, Elvan; Yaylali, Volkan; Cetin, Ebru Nevin; Yildirim, Cem
2011-09-01
The aim was to compare the effects of topical cyclosporine A and artificial tears combination with artificial tears alone in patients with dysfunctional tear syndrome (DTS). Forty-two eyes of 42 patients with DTS were enrolled in the study. The inclusion criteria for the study were Schirmer I (without anesthesia) scores below 10 mm/5 min and tear film break-up time (BUT) below 10 sec. The patients were randomly divided into two groups. The study group (22 patients) underwent 0.05% cyclosporine A treatment twice a day and preservative-free artificial tears for four times a day for 4 months. The control group (20 patients) was administered only preservative-free artificial tears four times a day for 4 months. The BUT, Schirmer test scores, corneal fluorescein staining, conjunctival lissamine green staining, and goblet cell density derived by impression cytology were recorded before and after treatment in each group. In the study group, all parameters improved statistically significantly after treatment at the 4-month follow-up compared with the pretreatment values (P<0.001 for all). In the control group, corneal fluorescein staining (P<0.001) and conjunctival lissamine green staining (P=0.014) improved, but BUT and Schirmer scores did not change significantly after treatment. At the end of the 4-month follow-up, the study group demonstrated statistically significantly better BUT (P=0.020), Schirmer scores (P=0.002), goblet cell density (P=0.006), corneal fluorescein staining (P=0.003), and conjunctival lissamine green staining (P=0.017) scores than did the control group. Topical cyclosporine A and artificial tears treatment significantly increases goblet cell density, decreases the signs of DTS, and improves ocular surface health.
A Comparison of Single-Cycle Versus Multiple-Cycle Proof Testing Strategies
NASA Technical Reports Server (NTRS)
McClung, R. C.; Chell, G. G.; Millwater, H. R.; Russell, D. A.; Millwater, H. R.
1999-01-01
Single-cycle and multiple-cycle proof testing (SCPT and MCPT) strategies for reusable aerospace propulsion system components are critically evaluated and compared from a rigorous elastic-plastic fracture mechanics perspective. Earlier MCPT studies are briefly reviewed. New J-integral estimation methods for semielliptical surface cracks and cracks at notches are derived and validated. Engineering methods are developed to characterize crack growth rates during elastic-plastic fatigue crack growth (FCG) and the tear-fatigue interaction near instability. Surface crack growth experiments are conducted with Inconel 718 to characterize tearing resistance, FCG under small-scale yielding and elastic-plastic conditions, and crack growth during simulated MCPT. Fractography and acoustic emission studies provide additional insight. The relative merits of SCPT and MCPT are directly compared using a probabilistic analysis linked with an elastic-plastic crack growth computer code. The conditional probability of failure in service is computed for a population of components that have survived a previous proof test, based on an assumed distribution of initial crack depths. Parameter studies investigate the influence of proof factor, tearing resistance, crack shape, initial crack depth distribution, and notches on the MCPT versus SCPT comparison. The parameter studies provide a rational basis to formulate conclusions about the relative advantages and disadvantages of SCPT and MCPT. Practical engineering guidelines are proposed to help select the optimum proof test protocol in a given application.
A Comparison of Single-Cycle Versus Multiple-Cycle Proof Testing Strategies
NASA Technical Reports Server (NTRS)
McClung, R. C.; Chell, G. G.; Millwater, H. R.; Russell, D. A.; Orient, G. E.
1996-01-01
Single-cycle and multiple-cycle proof testing (SCPT and MCPT) strategies for reusable aerospace propulsion system components are critically evaluated and compared from a rigorous elastic-plastic fracture mechanics perspective. Earlier MCPT studies are briefly reviewed. New J-integral estimation methods for semi-elliptical surface cracks and cracks at notches are derived and validated. Engineering methods are developed to characterize crack growth rates during elastic-plastic fatigue crack growth (FCG) and the tear-fatigue interaction near instability. Surface crack growth experiments are conducted with Inconel 718 to characterize tearing resistance, FCG under small-scale yielding and elastic-plastic conditions, and crack growth during simulated MCPT. Fractography and acoustic emission studies provide additional insight. The relative merits of SCPT and MCPT are directly compared using a probabilistic analysis linked with an elastic-plastic crack growth computer code. The conditional probability of failure in service is computed for a population of components that have survived a previous proof test, based on an assumed distribution of initial crack depths. Parameter studies investigate the influence of proof factor, tearing resistance, crack shape, initial crack depth distribution, and notches on the MCPT vs. SCPT comparison. The parameter studies provide a rational basis to formulate conclusions about the relative advantages and disadvantages of SCPT and MCPT. Practical engineering guidelines are proposed to help select the optimum proof test protocol in a given application.
Divalent cations in tears, and their influence on tear film stability in humans and rabbits.
Wei, Xiaojia Eric; Markoulli, Maria; Millar, Thomas J; Willcox, Mark D P; Zhao, Zhenjun
2012-06-05
Reduced tear film stability is reported to contribute to dry eye. Rabbits are known to have a more stable tear film than humans. Thus, we sought to examine the tears of rabbits and humans for metal cations, and to test how they influence tear film stability. Tears were collected from 10 healthy humans and 6 rabbits. Tear osmolality was measured by vapor pressure osmometer, and metals analyzed using inductively coupled plasma (ICP) mass spectrometry or ICP atomic emission spectroscopy. The influence of divalent cations on tears was analyzed by measuring surface tension using the Langmuir trough in vitro, using different concentrations of cations in the subphase, and grading the tear break-up in rabbits in vivo after instillation of chelating agents. Rabbit tears had a higher osmolality compared to humans. Major metals did not differ between species; however, rabbits had higher levels of Mg(2+) (1.13 vs. 0.39 mM) and Ca(2+) (0.75 vs. 0.36 mM). In rabbit tears in vitro, diminishing divalent cations resulted in a decrease in the maximum surface pressure from 37 to 30 mN/m. In vivo, an increase in the amount of tear film that was broken-up was found. In contrast, when changing divalent cation concentrations in human tears, the maximum surface pressure remained at 26 mN/m. The normal osmolality of rabbit tears is significantly higher than that in humans. While divalent cations had little influence on human tears, they appear to have an important role in maintaining tear film stability in rabbits.
Effect of viscosity on tear drainage and ocular residence time.
Zhu, Heng; Chauhan, Anuj
2008-08-01
An increase in residence time of dry eye medications including artificial tears will likely enhance therapeutic benefits. The drainage rates and the residence time of eye drops depend on the viscosity of the instilled fluids. However, a quantitative understanding of the dependence of drainage rates and the residence time on viscosity is lacking. The current study aims to develop a mathematical model for the drainage of Newtonian fluids and also for power-law non-Newtonian fluids of different viscosities. This study is an extension of our previous study on the mathematical model of tear drainage. The tear drainage model is modified to describe the drainage of Newtonian fluids with viscosities higher than the tear viscosity and power-law non-Newtonian fluids with rheological parameters obtained from fitting experimental data in literature. The drainage rate through canaliculi was derived from the modified drainage model and was incorporated into a tear mass balance to calculate the transients of total solute quantity in ocular fluids and the bioavailability of instilled drugs. For Newtonian fluids, increasing the viscosity does not affect the drainage rate unless the viscosity exceeds a critical value of about 4.4 cp. The viscosity has a maximum impact on drainage rate around a value of about 100 cp. The trends are similar for shear thinning power law fluids. The transients of total solute quantity, and the residence time agrees at least qualitatively with experimental studies. A mathematical model has been developed for the drainage of Newtonian fluids and power-law fluids through canaliculi. The model can quantitatively explain different experimental observations on the effect of viscosity on the residence of instilled fluids on the ocular surface. The current study is helpful for understanding the mechanism of fluid drainage from the ocular surface and for improving the design of dry eye treatments.
Evaporation-driven instability of the precorneal tear film.
Peng, Cheng-Chun; Cerretani, Colin; Braun, Richard J; Radke, C J
2014-04-01
Tear-film instability is widely believed to be a signature of eye health. When an interblink is prolonged, randomly distributed ruptures occur in the tear film. "Black spots" and/or "black streaks" appear in 15 to 40 s for normal individuals. For people who suffer from dry eye, tear-film breakup time (BUT) is typically less than a few seconds. To date, however, there is no satisfactory quantitative explanation for the origin of tear rupture. Recently, it was proposed that tear-film breakup is related to locally high evaporative thinning. A spatial variation in the thickness of the tear-film lipid layer (TFLL) may lead to locally elevated evaporation and subsequent tear-film breakup. We examine the local-evaporation-driven tear-film-rupture hypothesis in a one-dimensional (1-D) model for the evolution of a thin aqueous tear film overriding the cornea subject to locally elevated evaporation at its anterior surface and osmotic water influx at its posterior surface. Evaporation rate depends on mass transfer both through the coating lipid layer and through ambient air. We establish that evaporation-driven tear-film breakup can occur under normal conditions but only for higher aqueous evaporation rates. Predicted roles of environmental conditions, such as wind speed and relative humidity, on tear-film stability agree with clinical observations. More importantly, locally elevated evaporation leads to hyperosmolar spots in the tear film and, hence, vulnerability to epithelial irritation. In addition to evaporation rate, tear-film instability depends on the strength of healing flow from the neighboring region outside the breakup region, which is determined by the surface tension at the tear-film surface and by the repulsive thin-film disjoining pressure. This study provides a physically consistent and quantitative explanation for the formation of black streaks and spots in the human tear film during an interblink. Copyright © 2013 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arsenin, V. V., E-mail: arsenin-vv@nrcki.ru; Skovoroda, A. A., E-mail: skovoroda-aa@nrcki.ru
2015-12-15
Using a cylindrical model, a relatively simple description is presented of how a magnetic field perturbation stimulated by a low external helical current or a small helical distortion of the boundary and generating magnetic islands penetrates into a plasma column with a magnetic surface q=m/n to which tearing instability is attached. Linear analysis of the classical instability with an aperiodic growth of the perturbation in time shows that the perturbation amplitude in plasma increases in a resonant manner as the discharge parameters approach the threshold of tearing instability. In a stationary case, under the assumption on the helical character ofmore » equilibrium, which can be found from the two-dimensional nonlinear equation for the helical flux, there is no requirement for the small size of the island. Examples of calculations in which magnetic islands are large near the threshold of tearing instability are presented. The bifurcation of equilibrium near the threshold of tearing instability in plasma with a cylindrical boundary, i.e., the existence of helical equilibrium (along with cylindrical equilibrium) with large islands, is described. Moreover, helical equilibrium can also exist in the absence of instability.« less
Wei, Yi; Gadaria-Rathod, Neha; Epstein, Seth; Asbell, Penny
2013-12-23
To provide standard operating procedures (SOPs) for measuring tear inflammatory cytokine concentrations and to validate the resulting profile as a minimally invasive objective metric and biomarker of ocular surface inflammation for use in multicenter clinical trials on dry eye disease (DED). Standard operating procedures were established and then validated with cytokine standards, quality controls, and masked tear samples collected from local and distant clinical sites. The concentrations of the inflammatory cytokines in tears were quantified using a high-sensitivity human cytokine multiplex kit. A panel of inflammatory cytokines was initially investigated, from which four key inflammatory cytokines (IL-1β, IL-6, INF-γ, and TNF-α) were chosen. Results with cytokine standards statistically satisfied the manufacturer's quality control criteria. Results with pooled tear samples were highly reproducible and reliable with tear volumes ranging from 4 to 10 μL. Incorporation of the SOPs into clinical trials was subsequently validated. Tear samples were collected at a distant clinical site, stored, and shipped to our Biomarker Laboratory, where a masked analysis of the four tear cytokines was successfully performed. Tear samples were also collected from a feasibility study on DED. Inflammatory cytokine concentrations were decreased in tears of subjects who received anti-inflammatory treatment. Standard operating procedures for human tear cytokine assessment suitable for multicenter clinical trials were established. Tear cytokine profiling using these SOPs may provide objective metrics useful for diagnosing, classifying, and analyzing treatment efficacy in inflammatory conditions of the ocular surface, which may further elucidate the mechanisms involved in the pathogenesis of ocular surface disease.
[Alterations in tears aqueous layer during cytostatics treatment].
Wojciechowska, Katarzyna; Wieckowska-Szakiel, Marzena; Rózalska, Barbara; Jurowski, Piotr
2013-01-01
The aim of the study was to evaluate tears secretion, pH and lysozyme activity in tears aqueous layer during chemotherapy in lung, breast and bowel cancer. 36 patients were enrolled to the study. Depending on the type of cancer and type of chemotherapy patients were divided into three groups. Group I (12 patients) diagnosed with non-small-cell lung cancer treated with PE schema (cisplatin, etoposide), Group II (12 patients) with breast cancer treated with FAC schema (fluorouracil, doxorubicin, cyclophosphamide), Group III (12 patients) with bowel cancer treated with FU/LV schema (fluorouracil, leucovorin). In all the patients: Schirmer's I test, pH measurements and lysozyme test were performed. Patients were examined before chemotherapy, after 2nd, 4th, 6th cycle. In group I and II lowering of tears secretion (p < 0.001) was revealed. In group III there was higher tears secretion (p < 0.001). PH was lowered after 2nd chemotherapy course in group I and II. In further treatment pH value were in the same lower level as after the second course. In group III there was higher pH--more alkaline (p < 0.001) after 2nd cycle of treatment and it was on the same level to the end of the examination process. Lowering of lysozyme activity in the tears film in all groups (p < 0.001) was established. The higher alterations of the lysozyme activity were observed in group treated with FAC schema. Cytostatic treatment has major influence on tears aqueous layer causing alterations of tears secretions. PH alterations depending on type of chemotherapy was observed. Lowering of lysozyme activity in tears was observed. All the deteriorations aggravate with duration of chemotherapy. Alterations of tears film parameters during chemotherapy may influence upon eye surface homeostasis and infectious complication. tears aqueous layer, Schirmer's test, lysozyme activity, tears pH.
The tear turnover and tear clearance tests - a review.
Garaszczuk, Izabela K; Montes Mico, Robert; Iskander, D Robert; Expósito, Alejandro Cerviño
2018-03-01
The aim is to provide a summary of methods available for the assessment of tear turnover and tear clearance rates. The review defines tear clearance and tear turnover and describes their implication for ocular surface health. Additionally, it describes main types of techniques for measuring tear turnover, including fluorescein tear clearance tests, techniques utilizing electromagnetic spectrum and tracer molecule and novel experimental techniques utilizing optical coherence tomography and fluorescein profilometry. Areas covered: Internet databases (PubMed, Science Direct, Google Scholar) and most frequently cited references were used as a principal resource of information on tear turnover rate and tear clearance rate, presenting methodologies and equipment, as well as their definition and implications for the anterior eye surface health and function. Keywords used for data-search were as follows: tear turnover, tear clearance, fluorescein clearance, scintigraphy, fluorophotometry, tear flow, drainage, tear meniscus dynamics, Krehbiel flow and lacrimal functional unit. Expert commentary: After decades, the topic of tear turnover assessment has been reintroduced. Recently, new techniques have been developed to propose less invasive, less time consuming and simpler methodologies for the assessment of tear dynamics that have the potential to be utilized in clinical practice.
Ocular Pharmacology of Tear Film, Dry Eye, and Allergic Conjunctivitis.
Gulati, Shilpa; Jain, Sandeep
2017-01-01
Dry Eye Disease (DED) is "a multifactorial disease of the tears and ocular surface that results in symptoms of discomfort, visual disturbance, and tear-film instability with potential damage to the ocular surface." DED comprises two etiologic categories: aqueous-deficient dry eye (ADDE) and evaporative dry eye (EDE). Diagnostic workup of DED should include clinical history, symptom questionnaire, fluorescein TBUT, ocular surface staining grading, Schirmer I/II, lid and meibomian pathology, meibomian expression, followed by other available tests. New diagnostic tests employ the Oculus Keratograph, which performs non-invasive tear-film analysis and a bulbar redness (BR). The TearLab Osmolarity Test enables rapid clinical evaluation of tear osmolarity. Lipiview is a recently developed diagnostic tool that uses interferometry to quantitatively evaluate tear-film thickness. In DED, epithelial and inflammatory cells produce a variety of inflammatory mediators. A stagnant tear film and decreased concentration of mucin result in the accumulation of inflammatory factors that can penetrate tight junctions and cause epithelial cell death. DED treatment algorithms are based on severity of clinical signs and symptoms, and disease etiology. Therapeutic approaches include lubricating artificial tears and immunomodulatory agents.
The Effects of Increasing Ocular Surface Stimulation on Blinking and Tear Secretion
Wu, Ziwei; Begley, Carolyn G.; Port, Nicholas; Bradley, Arthur; Braun, Richard; King-Smith, Ewen
2015-01-01
Purpose. To investigate the effect of varying levels of ocular surface stimulation on the timing and amplitude of the blink and tear secretion. Methods. Following instillation of fluorescein dye, increasing levels of air flow were directed toward the central corneas of 10 healthy subjects. Interblink interval (IBI), tear meniscus height (TMH), and fluorescence intensity were measured simultaneously. Because blinking can obscure changes in TMH, we developed novel measures of tear secretion by calculating tear meniscus fluorescein concentration (TMFC) from intensity using a mathematical model. The change of TMH and TMFC over trials and the slope of the TMFC within each IBI (IBI-TTR) were further calculated. Results. The mean IBI was decreased by 8.08 ± 8.54 seconds from baseline to maximum air stimulation. The TMH increase was highly variable (0.41 ± 0.39 mm) among subjects, compared to the fluorescence tear turnover metrics: decrease in TMFC of 2.84 ± 0.98 natural logarithm or ln(%) and IBI-TTR of 0.065 ± 0.032 ln(%)/sec. Ocular surface stimulation was highly correlated with the TMFC and IBI-TTR, but less so with TMH (Pearson's r = 0.71, 0.69, and 0.40, P < 0.01, respectively). Blinking and tearing were significantly correlated with each other (Pearson's r = 0.56, P < 0.01), but tearing lagged behind by an average of 6.54 ± 4.07 seconds. Conclusions. Blinking and tearing share a common origin with sensory stimulation at the ocular surface. Both showed a dose–response increase with surface stimulation and were correlated with each other. These methods can potentially be used to understand alterations in ocular surface sensory function and associated protective responses in dry eye and other disorders of the ocular surface. PMID:26132780
The Effects of Increasing Ocular Surface Stimulation on Blinking and Tear Secretion.
Wu, Ziwei; Begley, Carolyn G; Port, Nicholas; Bradley, Arthur; Braun, Richard; King-Smith, Ewen
2015-07-01
To investigate the effect of varying levels of ocular surface stimulation on the timing and amplitude of the blink and tear secretion. Following instillation of fluorescein dye, increasing levels of air flow were directed toward the central corneas of 10 healthy subjects. Interblink interval (IBI), tear meniscus height (TMH), and fluorescence intensity were measured simultaneously. Because blinking can obscure changes in TMH, we developed novel measures of tear secretion by calculating tear meniscus fluorescein concentration (TMFC) from intensity using a mathematical model. The change of TMH and TMFC over trials and the slope of the TMFC within each IBI (IBI-TTR) were further calculated. The mean IBI was decreased by 8.08 ± 8.54 seconds from baseline to maximum air stimulation. The TMH increase was highly variable (0.41 ± 0.39 mm) among subjects, compared to the fluorescence tear turnover metrics: decrease in TMFC of 2.84 ± 0.98 natural logarithm or ln(%) and IBI-TTR of 0.065 ± 0.032 ln(%)/sec. Ocular surface stimulation was highly correlated with the TMFC and IBI-TTR, but less so with TMH (Pearson's r = 0.71, 0.69, and 0.40, P < 0.01, respectively). Blinking and tearing were significantly correlated with each other (Pearson's r = 0.56, P < 0.01), but tearing lagged behind by an average of 6.54 ± 4.07 seconds. Blinking and tearing share a common origin with sensory stimulation at the ocular surface. Both showed a dose-response increase with surface stimulation and were correlated with each other. These methods can potentially be used to understand alterations in ocular surface sensory function and associated protective responses in dry eye and other disorders of the ocular surface.
Biophysical characterization of monofilm model systems composed of selected tear film phospholipids.
Patterson, Matthew; Vogel, Hans J; Prenner, Elmar J
2016-02-01
The tear film protects the eye from foreign particles and pathogens, prevents excess evaporation, provides lubrication, and maintains a high quality optical surface necessary for vision. The anterior layer of tear film consists of polar and non-polar lipid layers. The polar lipids form a monolayer on the aqueous subphase, acting as surfactants for the non-polar lipid multilayer. A tear film polar lipid biomimetic consisting of dipalmitoyl phosphatidylcholine (DPPC), dipalmitoyl phosphatidylethanolamine (DPPE), palmitoyl glucosylceramide (PGC), and palmitoyl sphingomyelin (PSM) was characterized using Langmuir monolayers and Brewster angle microscopy (BAM). Lipid combinations formed very stable monolayers, especially those containing DPPC or PSM. Surface experiments and elasticity analyses revealed that PGC resulted in more condensed and rigid mixed monolayers. DPPE provided resistance to large changes in lipid ordering over a wide surface pressure range. Ternary mixtures containing DPPE and PGC with either DPPC or PSM experienced the greatest lipid ordering within the natural tear film surface pressure range suggesting that these lipids are important to maintain tear film integrity during the inter-blink period. Finally, BAM images revealed unique structures within monolayers of DPPC, DPPE, and PGC at the natural tear film surface pressure. 3D analysis of these domains suggested either the formation of multilayers or outward protrusions at surface pressures far below the point of irreversible collapse as seen on the isotherm. This entails that the polar lipids of tear film may be capable of multilayer formation or outward folding as a mechanism to prevent rupture of the tear film during a blink. Copyright © 2015 Elsevier B.V. All rights reserved.
Goldmann tonometry tear film error and partial correction with a shaped applanation surface.
McCafferty, Sean J; Enikov, Eniko T; Schwiegerling, Jim; Ashley, Sean M
2018-01-01
The aim of the study was to quantify the isolated tear film adhesion error in a Goldmann applanation tonometer (GAT) prism and in a correcting applanation tonometry surface (CATS) prism. The separation force of a tonometer prism adhered by a tear film to a simulated cornea was measured to quantify an isolated tear film adhesion force. Acrylic hemispheres (7.8 mm radius) used as corneas were lathed over the apical 3.06 mm diameter to simulate full applanation contact with the prism surface for both GAT and CATS prisms. Tear film separation measurements were completed with both an artificial tear and fluorescein solutions as a fluid bridge. The applanation mire thicknesses were measured and correlated with the tear film separation measurements. Human cadaver eyes were used to validate simulated cornea tear film separation measurement differences between the GAT and CATS prisms. The CATS prism tear film adhesion error (2.74±0.21 mmHg) was significantly less than the GAT prism (4.57±0.18 mmHg, p <0.001). Tear film adhesion error was independent of applanation mire thickness ( R 2 =0.09, p =0.04). Fluorescein produces more tear film error than artificial tears (+0.51±0.04 mmHg; p <0.001). Cadaver eye validation indicated the CATS prism's tear film adhesion error (1.40±0.51 mmHg) was significantly less than that of the GAT prism (3.30±0.38 mmHg; p =0.002). Measured GAT tear film adhesion error is more than previously predicted. A CATS prism significantly reduced tear film adhesion error bŷ41%. Fluorescein solution increases the tear film adhesion compared to artificial tears, while mire thickness has a negligible effect.
Relevance of Lipid-Based Products in the Management of Dry Eye Disease.
Garrigue, Jean-Sébastien; Amrane, Mourad; Faure, Marie-Odile; Holopainen, Juha M; Tong, Louis
2017-11-01
Components of the ocular surface synergistically contribute to maintaining and protecting a smooth refractive layer to facilitate the optimal transmission of light. At the air-water interface, the tear film lipid layer (TFLL), a mixture of lipids and proteins, plays a key role in tear surface tension and is important for the physiological hydration of the ocular surface and for ocular homeostasis. Alterations in tear fluid rheology, differences in lipid composition, or downregulation of specific tear proteins are found in most types of ocular surface disease, including dry eye disease (DED). Artificial tears have long been a first line of treatment in DED and aim to replace or supplement tears. More recently, lipid-containing eye drops have been developed to more closely mimic the combination of aqueous and lipid layers of the TFLL. Over the last 2 decades, our understanding of the nature and importance of lipids in the tear film in health and disease has increased substantially. The aim of this article is to provide a brief overview of our current understanding of tear film properties and review the effectiveness of lipid-based products in the treatment of DED. Liposome lid sprays, emulsion eye drops, and other lipid-containing formulations are discussed.
Recent developments on dry eye disease treatment compounds.
Colligris, Basilio; Alkozi, Hanan Awad; Pintor, Jesus
2014-01-01
Dry eye syndrome is a common tears and ocular surface multifactorial disease, described by changes in the ocular surface epithelia related to reduced tears quantity and ocular surface sensitivity, leading to inflammatory reaction. Managing the eye inflammation proved helpful to patients with dry eye disease and current treatment is based on the use of topically applied artificial tear products/lubricants, tear retention management, stimulation of tear secretion and using anti-inflammatory drugs. In this article we revise the corresponding literature and patents assembling the new treatment approaches of novel and future pharmaceutical compounds destined for the dry eye disease treatment. The most frequent categories of compounds presented are secretagogues and anti-inflammatory drugs. These compounds are the research outcome of novel therapeutic strategies designed to reduce key inflammatory pathways and restore healthy tear film.
Tearing as a test for mechanical characterization of thin adhesive films
NASA Astrophysics Data System (ADS)
Hamm, Eugenio; Reis, Pedro; Leblanc, Michael; Roman, Benoit; Cerda, Enrique
2008-05-01
Thin adhesive films have become increasingly important in applications involving packaging, coating or for advertising. Once a film is adhered to a substrate, flaps can be detached by tearing and peeling, but they narrow and collapse in pointy shapes. Similar geometries are observed when peeling ultrathin films grown or deposited on a solid substrate, or skinning the natural protective cover of a ripe fruit. Here, we show that the detached flaps have perfect triangular shapes with a well-defined vertex angle; this is a signature of the conversion of bending energy into surface energy of fracture and adhesion. In particular, this triangular shape of the tear encodes the mechanical parameters related to these three forms of energy and could form the basis of a quantitative assay for the mechanical characterization of thin adhesive films, nanofilms deposited on substrates or fruit skin.
Tearing as a test for mechanical characterization of thin adhesive films.
Hamm, Eugenio; Reis, Pedro; LeBlanc, Michael; Roman, Benoit; Cerda, Enrique
2008-05-01
Thin adhesive films have become increasingly important in applications involving packaging, coating or for advertising. Once a film is adhered to a substrate, flaps can be detached by tearing and peeling, but they narrow and collapse in pointy shapes. Similar geometries are observed when peeling ultrathin films grown or deposited on a solid substrate, or skinning the natural protective cover of a ripe fruit. Here, we show that the detached flaps have perfect triangular shapes with a well-defined vertex angle; this is a signature of the conversion of bending energy into surface energy of fracture and adhesion. In particular, this triangular shape of the tear encodes the mechanical parameters related to these three forms of energy and could form the basis of a quantitative assay for the mechanical characterization of thin adhesive films, nanofilms deposited on substrates or fruit skin.
Shaping effects on toroidal magnetohydrodynamic modes in the presence of plasma and wall resistivity
NASA Astrophysics Data System (ADS)
Rhodes, Dov J.; Cole, A. J.; Brennan, D. P.; Finn, J. M.; Li, M.; Fitzpatrick, R.; Mauel, M. E.; Navratil, G. A.
2018-01-01
This study explores the effects of plasma shaping on magnetohydrodynamic mode stability and rotational stabilization in a tokamak, including both plasma and wall resistivity. Depending upon the plasma shape, safety factor, and distance from the wall, the β-limit for rotational stabilization is given by either the resistive-plasma ideal-wall (tearing mode) limit or the ideal-plasma resistive-wall (resistive wall mode) limit. In order to explore this broad parameter space, a sharp-boundary model is developed with a realistic geometry, resonant tearing surfaces, and a resistive wall. The β-limit achievable in the presence of stabilization by rigid plasma rotation, or by an equivalent feedback control with imaginary normal-field gain, is shown to peak at specific values of elongation and triangularity. It is shown that the optimal shaping with rotation typically coincides with transitions between tearing-dominated and wall-dominated mode behavior.
Clinical guidelines for management of dry eye associated with Sjögren disease.
Foulks, Gary N; Forstot, S Lance; Donshik, Peter C; Forstot, Joseph Z; Goldstein, Michael H; Lemp, Michael A; Nelson, J Daniel; Nichols, Kelly K; Pflugfelder, Stephen C; Tanzer, Jason M; Asbell, Penny; Hammitt, Katherine; Jacobs, Deborah S
2015-04-01
To provide a consensus clinical guideline for management of dry eye disease associated with Sjögren disease by evaluating published treatments and recommending management options. Consensus panel evaluation of reported treatments for dry eye disease. Using the 2007 Report of the International Workshop on Dry Eye (DEWS) as a starting point, a panel of eye care providers and consultants evaluated peer-reviewed publications and developed recommendations for evaluation and management of dry eye disease associated with Sjögren disease. Publications were graded according to the American Academy of Ophthalmology Preferred Practice Pattern guidelines for level of evidence. Strength of recommendation was according to the Grading of Recommendations Assessment, Development and Evaluation (GRADE) guidelines. The recommendations of the panel are briefly summarized herein. Evaluation should include symptoms of both discomfort and visual disturbance as well as determination of the relative contribution of aqueous production deficiency and evaporative loss of tear volume. Objective parameters of tear film stability, tear osmolarity, degree of lid margin disease, and ocular surface damage should be used to stage severity of dry eye disease to assist in selecting appropriate treatment options. Patient education with regard to the nature of the problem, aggravating factors, and goals of treatment is critical to successful management. Tear supplementation and stabilization, control of inflammation of the lacrimal glands and ocular surface, and possible stimulation of tear production are treatment options that are used according to the character and severity of dry eye disease. Management guidelines for dry eye associated with Sjögren's disease are presented. Copyright © 2015 Elsevier Inc. All rights reserved.
Modeling Corneal Oxygen with Scleral Gas Permeable Lens Wear.
Compañ, Vicente; Aguilella-Arzo, Marcel; Edrington, Timothy B; Weissman, Barry A
2016-11-01
The main goal of this current work is to use an updated calculation paradigm, and updated boundary conditions, to provide theoretical guidelines to assist the clinician whose goal is to improve his or her scleral gas permeable (GP) contact lens wearing patients' anterior corneal oxygen supply. Our model uses a variable value of corneal oxygen consumption developed through Monod equations that disallows negative oxygen tensions within the stroma to predict oxygen tension at the anterior corneal surface of scleral GP contact lens wearing eyes, and to describe oxygen tension and flux profiles, for various boundary conditions, through the lens, tears, and cornea. We use several updated tissue and boundary parameters in our model. Tear exchange with GP scleral lenses is considered nonexistent in this model. The majority of current scleral GP contact lenses should produce some levels of corneal hypoxia under open eye conditions. Only lenses producing the thinnest of tear vaults should result in anterior corneal surface oxygen tensions greater than a presumed critical oxygen tension of 100 mmHg. We also find that corneal oxygen tension and flux are each more sensitive to modification in tear vault than to changes in lens oxygen permeability, within the ranges of current clinical manipulation. Our study suggests that clinicians would be prudent to prescribe scleral GP lenses manufactured from higher oxygen permeability materials and especially to fit without excessive corneal clearance.
JBP485 promotes tear and mucin secretion in ocular surface epithelia
Nakamura, Takahiro; Hata, Yuiko; Nagata, Maho; Yokoi, Norihiko; Yamaguchi, Shumpei; Kaku, Taiichi; Kinoshita, Shigeru
2015-01-01
Dry eye syndrome (DES), a multifactorial disease of the tears and ocular surface, is one of the most common ocular disorders. Tear film contains ocular mucins and is essential for maintaining the homeostasis of the wet ocular surface. Since there are a limited number of clinical options for the treatment of DES, additional novel treatments are needed to improve the clinical results. In this study, we found that placental extract-derived dipeptide (JBP485) clearly promoted the expression and secretion of gel-forming mucin 5ac (Muc5ac) in rabbit conjunctival epithelium. JBP485 also elevated the expression level of cell surface-associated mucins (Muc1/4/16) in rabbit corneal epithelium. The Schirmer tear test results indicated that JBP485 induced tear secretion in the rabbit model. Moreover, JBP485 clinically improved corneal epithelial damage in a mouse dry eye model. Thus, our data indicate that JBP485 efficiently promoted mucin and aqueous tear secretion in rabbit ocular surface epithelium and has the potential to be used as a novel treatment for DES. PMID:25996902
JBP485 promotes tear and mucin secretion in ocular surface epithelia.
Nakamura, Takahiro; Hata, Yuiko; Nagata, Maho; Yokoi, Norihiko; Yamaguchi, Shumpei; Kaku, Taiichi; Kinoshita, Shigeru
2015-05-21
Dry eye syndrome (DES), a multifactorial disease of the tears and ocular surface, is one of the most common ocular disorders. Tear film contains ocular mucins and is essential for maintaining the homeostasis of the wet ocular surface. Since there are a limited number of clinical options for the treatment of DES, additional novel treatments are needed to improve the clinical results. In this study, we found that placental extract-derived dipeptide (JBP485) clearly promoted the expression and secretion of gel-forming mucin 5ac (Muc5ac) in rabbit conjunctival epithelium. JBP485 also elevated the expression level of cell surface-associated mucins (Muc1/4/16) in rabbit corneal epithelium. The Schirmer tear test results indicated that JBP485 induced tear secretion in the rabbit model. Moreover, JBP485 clinically improved corneal epithelial damage in a mouse dry eye model. Thus, our data indicate that JBP485 efficiently promoted mucin and aqueous tear secretion in rabbit ocular surface epithelium and has the potential to be used as a novel treatment for DES.
Recent developments on dry eye disease treatment compounds
Colligris, Basilio; Alkozi, Hanan Awad; Pintor, Jesus
2013-01-01
Dry eye syndrome is a common tears and ocular surface multifactorial disease, described by changes in the ocular surface epithelia related to reduced tears quantity and ocular surface sensitivity, leading to inflammatory reaction. Managing the eye inflammation proved helpful to patients with dry eye disease and current treatment is based on the use of topically applied artificial tear products/lubricants, tear retention management, stimulation of tear secretion and using anti-inflammatory drugs. In this article we revise the corresponding literature and patents assembling the new treatment approaches of novel and future pharmaceutical compounds destined for the dry eye disease treatment. The most frequent categories of compounds presented are secretagogues and anti-inflammatory drugs. These compounds are the research outcome of novel therapeutic strategies designed to reduce key inflammatory pathways and restore healthy tear film. PMID:24526854
Yoon, Jin Sook; Choi, Soo Hyun; Lee, Joon H; Lee, Sung Jun; Lee, Sang Yeul
2010-02-01
To measure tear nerve growth factor (NGF) concentrations in cases of active thyroid-associated ophthalmopathy (TAO) before and after glucocorticoid treatment, and to correlate NGF levels with disease inflammatory activity and thyroid autoantibody concentration. The study involved 20 patients with active TAO and 20 age- and gender-matched controls. Tear break-up time (BUT) was obtained, the Schirmer test was performed, and tear NGF/total protein ratio was measured in control subjects and patients with active TAO before, and 2 and 4 weeks after, steroid treatment. Tear BUT and Schirmer values significantly increased after 2 and 4 weeks of steroid treatment (p < 0.001 and p = 0.004 respectively). Baseline tear NGF/total protein ratio was higher in patients with active TAO than in control subjects, and the ratio significantly decreased after 2 and 4 weeks of steroid treatment (p < 0.001). Tear NGF/total protein ratio did not correlate with inflammatory activity score, exophthalmos value and thyroid binding inhibiting immunoglobulin (TBII) level (p > 0.05). Tear NGF may have a specific role in ocular surface inflammation, which protects against ocular surface damage in patients with active TAO. Anti-inflammatory treatment significantly reduced the level of NGF in tears, increased tear film stability and production, and decreased congestive symptoms.
Interferometric measurements of the tear film irregularities on the human cornea
NASA Astrophysics Data System (ADS)
Szczesna, Dorota H.; Jaronski, Jaroslaw; Kasprzak, Henryk T.; Stenevi, Ulf
2005-09-01
The pre-ocular tear film is the most anterior refractive surface of the eye. Its stability plays an important role in the condition of vision from the optical and physiological point of view. If the eye is opened for a significantly long time or suffers from an anormalities in tear production, there appear isolated dry islands - break-ups - with a random distribution in the continuous lacrimal film. We applied an interferometric method - Lateral Shearing Technique for investigating the tear film stability and the smoothness of the tear film surface. This method is non-invasive and it is characterised by the high accuracy and sensitivity. Interferometry allows dynamic measurements of the tear film stability in real time by observation of interference fringes. The evaporation of tears and appearance of the breakups causes changes in the fringe geometry. Fast Fourier Transform has been used for quantitative assessment of the fringe smoothness and as a consequence of the tear film surface geometry. This paper presents the method used for quantitative evaluation of the tear film distribution on the cornea. Examples of interferograms recorded on eyes of patients with healthy eyes, suffering from dry eye syndrome and wearing contact lenses are also given. With our technique we were able to observe distinct differences in stability of the tear film between healthy and dry eyes, and the tear film on contact lenses.
Relevance of Lipid-Based Products in the Management of Dry Eye Disease
Amrane, Mourad; Faure, Marie-Odile; Holopainen, Juha M.; Tong, Louis
2017-01-01
Abstract Components of the ocular surface synergistically contribute to maintaining and protecting a smooth refractive layer to facilitate the optimal transmission of light. At the air–water interface, the tear film lipid layer (TFLL), a mixture of lipids and proteins, plays a key role in tear surface tension and is important for the physiological hydration of the ocular surface and for ocular homeostasis. Alterations in tear fluid rheology, differences in lipid composition, or downregulation of specific tear proteins are found in most types of ocular surface disease, including dry eye disease (DED). Artificial tears have long been a first line of treatment in DED and aim to replace or supplement tears. More recently, lipid-containing eye drops have been developed to more closely mimic the combination of aqueous and lipid layers of the TFLL. Over the last 2 decades, our understanding of the nature and importance of lipids in the tear film in health and disease has increased substantially. The aim of this article is to provide a brief overview of our current understanding of tear film properties and review the effectiveness of lipid-based products in the treatment of DED. Liposome lid sprays, emulsion eye drops, and other lipid-containing formulations are discussed. PMID:28956698
Tear dynamics in healthy and dry eyes.
Cerretani, Colin F; Radke, C J
2014-06-01
Dry-eye disease, an increasingly prevalent ocular-surface disorder, significantly alters tear physiology. Understanding the basic physics of tear dynamics in healthy and dry eyes benefits both diagnosis and treatment of dry eye. We present a physiological-based model to describe tear dynamics during blinking. Tears are compartmentalized over the ocular surface; the blink cycle is divided into three repeating phases. Conservation laws quantify the tear volume and tear osmolarity of each compartment during each blink phase. Lacrimal-supply and tear-evaporation rates are varied to reveal the dependence of tear dynamics on dry-eye conditions, specifically tear osmolarity, tear volume, tear-turnover rate (TTR), and osmotic water flow. Predicted periodic-steady tear-meniscus osmolarity is 309 and 321 mOsM in normal and dry eyes, respectively. Tear osmolarity, volume, and TTR all match available clinical measurements. Osmotic water flow through the cornea and conjunctiva contribute 10 and 50% to the total tear supply in healthy and dry-eye conditions, respectively. TTR in aqueous-deficient dry eye (ADDE) is only half that in evaporative dry eye (EDE). The compartmental periodic-steady tear-dynamics model accurately predicts tear behavior in normal and dry eyes. Inclusion of osmotic water flow is crucial to match measured tear osmolarity. Tear-dynamics predictions corroborate the use of TTR as a clinical discriminator between ADDE and EDE. The proposed model is readily extended to predict the dynamics of aqueous solutes such as drugs or fluorescent tags.
Adsorption of lysozyme to phospholipid and meibomian lipid monolayer films.
Mudgil, Poonam; Torres, Margaux; Millar, Thomas J
2006-03-15
It is believed that a lipid layer forms the outer layer of the pre-ocular tear film and this layer helps maintain tear film stability by lowering its surface tension. Proteins of the aqueous layer of the tear film (beneath the lipid layer) may also contribute to reducing surface tension by adsorbing to, or penetrating the lipid layer. The purpose of this study was to compare the penetration of lysozyme, a tear protein, into films of meibomian lipids and phospholipids held at different surface pressures to determine if lysozyme were part of the surface layer of the tear film. Films of meibomian lipids or phospholipids were spread onto the surface of a buffered aqueous subphase. Films were compressed to particular pressures and lysozyme was injected into the subphase. Changes in surface pressure were monitored to determine adsorption or penetration of lysozyme into the surface film. Lysozyme penetrated a meibomian lipid film at all pressures tested (max=20 mN/m). It also penetrated phosphatidylglycerol, phosphatidylserine or phosphatidylethanolamine lipid films up to a pressure of 20 mN/m. It was not able to penetrate a phosphatidylcholine film at pressures >or=10 mN/m irrespective of the temperature being at 20 or 37 degrees C. However, it was able to penetrate it at very low pressures (<10 mN/m). Epifluorescence microscopy showed that the protein either adsorbs to or penetrates the lipid layer and the pattern of mixing depended upon the lipid at the surface. These results indicate that lysozyme is present at the surface of the tear film where it contributes to decreasing the surface tension by adsorbing and penetrating the meibomian lipids. Thus it helps to stabilize the tear film.
Ohguchi, Takeshi; Kojima, Takashi; Ibrahim, Osama M; Nagata, Taeko; Shimizu, Takahiko; Shirasawa, Takuji; Kawakita, Tetsuya; Satake, Yoshiyuki; Tsubota, Kazuo; Shimazaki, Jun; Ishida, Susumu
2013-11-21
To investigate the efficacy of 2% rebamipide ophthalmic solution on the tear functions and ocular surface status of the superoxide dismutase-1(Sod1(-/-)) mice. Two percent Rebamipide ophthalmic solution was applied to 40-week-old male Sod1(-/-) and wild-type (WT) mice four times a day for 2 weeks. We examined the cytokine concentrations in the tear fluid (by CytoBead assay), tear film break-up time, amount of tear production, and expressions of mucins 1, 4, and 5AC, by RT-PCR. We also performed vital staining of the ocular surface, PAS staining for muc5AC, and immunohistochemical stainings for 4-hydroxy-2-nonenal (4-HNE), 8-hydroxy-2'-deoxyguanosine (8-OHdG), in the conjunctiva to compare the results before and after rebamipide instillations. The tear functions and ocular surface epithelial damage scores were significantly worse in the Sod1(-/-) than in the WT mice. Application of 2% rebamipide for 2 weeks significantly improved the tear film break-up time, the amount of tear production, and the corneal epithelial damage scores, which also significantly increased the conjunctival goblet cell density and muc5 mRNA expression, in the Sod1(-/-) mice. The mean IL-6, IL-17, TNF-α, and IFN-γ levels in the tear fluid were reduced significantly along with a significant decrease in the density of cells positive for 4-HNE and 8-OHdG in the conjunctiva. Two percent Rebamipide ophthalmic solution significantly improved the tear stability and corneal epithelial damage, and enhanced the expression of muc5 mRNA on the ocular surface. We also observed anti-inflammatory effects in the tear film together with antioxidative effects in the conjunctiva, suggesting the efficacy of rebamipide in age-related dry eye disease attributable to SOD1 knockout.
... JavaScript. Watery eyes means you have too many tears draining from the eyes. Tears help keep the surface of the eye moist. ... the eye. Causes Your eyes are always making tears. These tears leave the eye through a small ...
Changes in the tear film and ocular surface from dry eye syndrome.
Johnson, Michael E; Murphy, Paul J
2004-07-01
Dry eye syndrome (DES) refers to a spectrum of ocular surface diseases with diverse and frequently multiple aetiologies. The common feature of the various manifestations of DES is an abnormal tear film. Tear film abnormalities associated with DES are tear deficiency, owing to insufficient supply or excessive loss, and anomalous tear composition. These categorizations are artificial, as in reality both often coexist. DES disrupts the homeostasis of the tear film with its adjacent structures, and adversely affects its ability to perform essential functions such as supporting the ocular surface epithelium and preventing microbial invasion. In addition, whatever the initial trigger, moderate and severe DES is characterized by ocular surface inflammation, which in turn becomes the cause and consequence of cell damage, creating a self-perpetuating cycle of deterioration. Progress has been made in our understanding of the aetiology and pathogenesis of DES, and these advances have encouraged a proliferation of therapeutic options. This article aims to amalgamate prevailing ideas of DES development, and to assist in that, relevant aspects of the structure, function, and production of the tear film are reviewed. Additionally, a synopsis of therapeutic strategies for DES is presented, detailing treatments currently available, and those in development.
Chisari, Giuseppe; Chisari, Eleonora M; Borzi, Antonio M; Chisari, Clara G
2017-01-01
Aging and oxidative stress seem to play a key role in the onset and progression of ocular surface diseases. Dry Eye Syndrome (DES) is a multifactorial disease of the tears and ocular surface in which symptoms may interfere with the ability to work and carry out daily functions. This clinical trial was a pilot study to evaluate the effects of supplementation with mixture (Saccharomyces boulardii MUCL 53837 and Enterococcus faecium LMG S-28935) on the tear film. Following the run-in period subjects were randomized in two groups: group A (n.30 subjects) and group B (n.30 subjects). Group A (control) treated only with substitute tear and group B treated with substitute tear + mixture (probiotic). The data obtained in the two study groups A and B were, respectively the following: Schirmer I: 9.2±0.2 vs. 12.8±0.4 (p< 0.001); Schirmer II: 3.6±0.1 vs. 4.6±0.2 (p<0.001); BUT 3.8±0.3 vs. 6.2±0.2 (p<0.001). Culture test showed initial bacterial growth in group "A" (placebo) 27 out of 60 samples tested, corresponding to 45.0% and "B" after treatment (probiotic) was found positive culture whit growth of bacteria in 18 tests equal to 30.0%. The total numbers of isolations of aerobic and anaerobic bacteria found group A and B after treatment. A reduction of 23 to 16 strains of aerobic and anaerobic isolates from 13 to 7 has been found. The administration of probiotics strains was effective in reducing DES. In light of these results, we have identified our probiotic (Saccharomyces boulardii MUCL 53837 and Enterococcus faecium LMG S-28935) activity integration with the action of tear substitutes, along with standardization of clinical parameters of the tear film and microbiological activity in restoring of the microbiota ocular surface subject with DES. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Interferometric characterization of tear film dynamics
NASA Astrophysics Data System (ADS)
Primeau, Brian Christopher
The anterior refracting surface of the eye is the thin tear film that forms on the surface of the cornea. When a contact lens is on worn, the tear film covers the contact lens as it would a bare cornea, and is affected by the contact lens material properties. Tear film irregularity can cause both discomfort and vision quality degradation. Under normal conditions, the tear film is less than 10 microns thick and the thickness and topography change in the time between blinks. In order to both better understand the tear film, and to characterize how contact lenses affect tear film behavior, two interferometers were designed and built to separately measure tear film behavior in vitro and in vivo. An in vitro method of characterizing dynamic fluid layers applied to contact lenses mounted on mechanical substrates has been developed using a phase-shifting Twyman-Green interferometer. This interferometer continuously measures light reflected from the surface of the fluid layer, allowing precision analysis of the dynamic fluid layer. Movies showing this fluid layer behavior can be generated. The fluid behavior on the contact lens surface is measured, allowing quantitative analysis beyond what typical contact angle or visual inspection methods provide. The in vivo interferometer is a similar system, with additional modules included to provide capability for human testing. This tear film measurement allows analysis beyond capabilities of typical fluorescein visual inspection or videokeratometry and provides better sensitivity and resolution than shearing interferometry methods.
Interferometer for measuring dynamic corneal topography
NASA Astrophysics Data System (ADS)
Micali, Jason Daniel
The cornea is the anterior most surface of the eye and plays a critical role in vision. A thin fluid layer, the tear film, coats the outer surface of the cornea and serves to protect, nourish, and lubricate the cornea. At the same time, the tear film is responsible for creating a smooth continuous surface where the majority of refraction takes place in the eye. A significant component of vision quality is determined by the shape of the cornea and stability of the tear film. It is desirable to possess an instrument that can measure the corneal shape and tear film surface with the same accuracy and resolution that is currently performed on common optical elements. A dual interferometer system for measuring the dynamic corneal topography is designed, built, and verified. The completed system is validated by testing on human subjects. The system consists of two co-aligned polarization splitting Twyman-Green interferometers designed to measure phase instantaneously. The primary interferometer measures the surface of the tear film while the secondary interferometer simultaneously tracks the absolute position of the cornea. Eye motion, ocular variation, and a dynamic tear film surface will result in a non-null configuration of the surface with respect to the interferometer system. A non-null test results in significant interferometer induced errors that add to the measured phase. New algorithms are developed to recover the absolute surface topography of the tear film and corneal surface from the simultaneous interferometer measurements. The results are high-resolution and high-accuracy surface topography measurements of the in vivo cornea that are captured at standard camera frame rates. This dissertation will cover the development and construction of an interferometer system for measuring the dynamic corneal topography of the human eye. The discussion starts with the completion of an interferometer for measuring the tear film. The tear film interferometer is part of an ongoing research project that has spanned multiple dissertations. For this research, the instrument was tested on human subjects and resulted in refinements to the interferometer design. The final configuration of the tear film interferometer and results from human subjects testing are presented. Feedback from this instrument was used to support the development and construction of the interferometric corneal topographer system. A calibration is performed on the instrument, and then verified against simulated eye surfaces. Finally, the instrument is validated by testing on human subjects. The result is an interferometer system that can non-invasively measure the dynamic corneal topography with greater accuracy and resolution than existing technologies.
Mukhopadhyay, Somnath; Sen, Swarnali; Datta, Himadri
2015-01-01
To compare the role of topically applied serum therapy with preservative-free artificial tear (AT) drops in patients with moderate to severe dry eye in Hansen's disease along with change in tear protein profile. 144 consecutive patients were randomly divided into three groups. After a baseline examination of clinical parameters, each of the patients received designated modality of topical therapy six times a day for 6 weeks. Post-treatment documentation of clinical parameters was done at 6 weeks, and then at 12 weeks after discontinuation of topical therapy. Analysis of three tear proteins using gel electrophoresis (sodium dodecyl sulfate polyacrylamide gel electrophoresis) was done at baseline, at the first and second post-treatment visits. In the cord blood serum (CBS) group, except for McMonnies score and staining score, all other clinical parameters showed continued improvement in the first and second post-treatment analyses. In the autologous serum (ALS) group, all the clinical parameters except Schirmer's I showed significant improvement in the first post-treatment analysis .This was sustained at a significant level in the second analysis except for tear film break-up time (TBUT) and conjunctival impression cytology grading. In the AT group, all the parameters improved at a non-significant level except for TBUT in the first analysis. In the next analysis, apart from McMonnies score and TBUT, other clinical parameters did not improve. In the ALS and CBS groups, tear lysozyme, lactoferrin levels improved in both post-treatment measurements (statistically insignificant).Total tear protein continued to increase at statistically significant levels in the first and second post-treatment analyses in the CBS group and at a statistically insignificant level in the ALS group. In the AT group, the three tear proteins continued to decrease in both the analyses. In moderate to severe dry eye in Hansen's disease, serum therapy in comparison with AT drops, improves clinical parameters and causes betterment in tear protein profile. CTRI/2013/07/003802. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Examination of in vivo tear film stability after eye blink and eye drying
NASA Astrophysics Data System (ADS)
Szczesna, Dorota H.; Kulas, Zbigniew; Kasprzak, Henryk T.; Stenevi, Ulf
2007-07-01
The purpose of this study is to investigate the kinetics of precorneal tear film stabilization process after eye blink and the process of creating the break-up of the tear film layer. The tear film of patients were examined in vivo by used the lateral shearing interferometer. The information about the distribution and stability of the tear film over the cornea is carried by the wave front reflected from the surface of tears and coded in interference fringes. Smooth and regular fringes indicate the smooth surface of tears over the cornea. Immediately after eye blink the interference fringes are observed on background of bright and dark areas. The contrast of this structure fades with time slowly and after 1-3 sec the background of interference fringes becomes uniform. The vertical orientation and instability of this structure suggests connection with eyelid movement and the spread of tears. If the eye is kept open for a long time, bright lines appear in the background of fringes after a dozen seconds. The slowly appearing structure might signify the tear film break-up. In case of eyes after a LASIK surgery the shape of the background structure has different nature and might be stable in time suggesting the stability of the corneal surface irregularities.
The Relationship between Metabolic Syndrome, Its Components, and Dry Eye: A Cross-Sectional Study.
Erdur, Sevil Karaman; Aydin, Rukiye; Ozsutcu, Mustafa; Olmuscelik, Oktay; Eliacik, Mustafa; Demirci, Goktug; Kocabora, Mehmet Selim
2017-08-01
The aim of this study was to evaluate tear osmolarity and tear film function and ocular surface changes in patients with metabolic syndrome. 108 eyes of 64 patients with metabolic syndrome (group 1) and 110 eyes of 55 healthy individuals (group 2) were included in this cross-sectional study. All participants were evaluated using the Ocular Surface Disease Index (OSDI) questionnaire, Schirmer I test, tear film break-up time (TBUT), and tear osmolarity. Main outcome measures were Ocular Surface Disease Index (OSDI) questionnaire, Schirmer I test, tear film break-up time (TBUT), and tear osmolarity values. Tear osmolarity values and OSDI scores were significantly higher in group 1 (314.4 ± 19.1 mOsm and 38.9 ± 1.1, respectively) compared with group 2 (295 ± 14.3 mOsm and 18.69 ± 17.2, respectively) (p = 0.01 for both). The Schirmer test values and TBUT in group 1 (10 ± 3.7 mm and 14.8 ± 3.6 sec, respectively) were significantly lower compared with group 2 (16.8 ± 2.6 mm and 18.1 ± 0.5 sec, respectively) (p < 0.001 for both). There was significant correlation between tear osmolarity versus waist circumference and fasting blood glucose in the study group (r = 0.364, p = 0.04; and r = 0.542, p ≤ 0.001, respectively). This study showed that metabolic syndrome can influence tear osmolarity and tear film function. Patients with metabolic syndrome showed tear hyperosmolarity and tear film dysfunction.
Human tear serotonin levels correlate with symptoms and signs of dry eye
Chhadva, Priyanka; Lee, Tinthu; Sarantopoulos, Constantine D.; Hackam, Abigail S.; McClellan, Allison L.; Felix, Elizabeth R.; Levitt, Roy C.; Galor, Anat
2015-01-01
Purpose Serotonin, a neurotransmitter known to be involved in nociceptor sensitization, is present in human tears. The purpose of this study was to correlate tear serotonin levels, as a marker of nociceptor sensitization, to facets of dry eye (DE) including symptoms and signs. Design Cross-sectional study Participants Sixty-two patients with normal eyelid and corneal anatomy were prospectively recruited from a Veterans Administration Ophthalmology Clinic over 11 months. Methods DE symptoms (Ocular Surface Disease Index [OSDI]), signs (tear break-up time [TBUT], corneal staining, and Schirmer’s score), and clinical descriptors of neuropathic ocular pain (NOP) (sensitivity to light and/or sensitivity to wind) were assessed. For tear analysis, each patient’s tears were collected after instilling 50µl of sterile saline to the lower cul-de-sac of each eye and using capillary action microcaps to collect the ocular wash. Tear serotonin levels were measured using enzyme-linked immunosorbent assay. Main Outcomes Measured Correlations between tear serotonin concentrations and DE symptoms and signs. Results The mean age of the population was 61±14 years and 84% (n=52) of the patients were male. Serotonin concentrations negatively correlated with Schirmer’s scores (r=−0.28; p=0.02), but did not correlate with other DE parameters, such as OSDI scores, sensitivity to light or wind, TBUT, or staining. According to our hypothesis, we divided patients into groups based on both DE symptoms and aqueous tear production; serotonin concentrations were found to be significantly higher in DE group 1 (OSDI≥6 and Schirmer’s<8) compared to both DE group 2 (OSDI≥6 and Schirmer’s≥8) and controls (OSDI<6 and Schirmer’s≥8). Patients in the DE group 2 more frequently complained of sensitivity to light (64%) and wind (67%) compared to the DE group 1 (40% and 60%, respectively) and controls (8% and 17%, respectively). Conclusion Patients with DE symptoms and aqueous tear deficiency had higher tear serotonin levels compared to those with DE symptoms but normal tear production and those without DE symptoms. PMID:25983214
Schicht, Martin; Garreis, Fabian; Hartjen, Nadine; Beileke, Stephanie; Jacobi, Christina; Sahin, Afsun; Holland, Detlef; Schröder, Henrik; Hammer, Christian M; Paulsen, Friedrich; Bräuer, Lars
2018-06-28
The study aimed to characterize the expression and function of SFTA3 at the ocular surface and in tears. Ocular tissues, conjunctival (HCjE) and human corneal (HCE) epithelial cell lines as well as tearfilm of patients suffering from different forms of dry eye disease (DED) were analyzed by means of RT-PCR, western blot, immunohistochemistry, and ELISA. A possible role of recombinant SFTA3 in corneal wound healing was investigated performing in vitro scratch assays. Tear film regulatory properties were analyzed with the spinning drop method and the regulation of SFTA3 transcripts was studied in HCE and HCjE after incubation with proinflammatory cytokines as well as typical ocular pathogens by real-time RT-PCR and ELISA. The results reveal that human ocular tissue as well as tears of healthy volunteers express SFTA3 whereas tears from patients with DED showed significantly increased SFTA3 levels. In vitro wounding of HCE cell cultures that had been treated with recombinant SFTA3 demonstrated a significantly increased wound closure rate and rSFTA3 reduced the surface tension of tear fluid. The results indicate that SFTA3 at the ocular surface seemed to be involved in wound healing and the reduction of surface tension.
NASA Astrophysics Data System (ADS)
Szczesna, Dorota H.; Kulas, Zbigniew; Kasprzak, Henryk T.; Stenevi, Ulf
2009-11-01
A lateral shearing interferometer was used to examine the smoothness of the tear film. The information about the distribution and stability of the precorneal tear film is carried out by the wavefront reflected from the surface of tears and coded in interference fringes. Smooth and regular fringes indicate a smooth tear film surface. On corneae after laser in situ keratomileusis (LASIK) or radial keratotomy (RK) surgery, the interference fringes are seldom regular. The fringes are bent on bright lines, which are interpreted as tear film breakups. The high-intensity pattern seems to appear in similar location on the corneal surface after refractive surgery. Our purpose was to extract information about the pattern existing under the interference fringes and calculate its shape reproducibility over time and following eye blinks. A low-pass filter was applied and correlation coefficient was calculated to compare a selected fragment of the template image to each of the following frames in the recorded sequence. High values of the correlation coefficient suggest that irregularities of the corneal epithelium might influence tear film instability and that tear film breakup may be associated with local irregularities of the corneal topography created after the LASIK and RK surgeries.
Significance of mucin on the ocular surface.
Watanabe, Hitoshi
2002-03-01
To review the significance of mucin in the tear film and the ocular surface epithelium. Summary of the information on how mucin derived from the corneal and conjunctival epithelia and from goblet cells plays a role in the stability of the tear film over the ocular surface. The change in mucin expression derived from the ocular surface epithelium is also discussed with reference to ocular surface disease. The corneal and conjunctival epithelia produce transmembrane mucins such as MUC1, MUC2, and MUC4. In contrast, goblet cells produce the gel-forming secretory mucin, MUC5AC. The lacrimal gland produces MUC7. On the ocular surface, cooperation between transmembrane mucin and secretory mucin is necessary for the stability of the tear film. The expression of mucin from the ocular surface epithelium is coordinated from the time of eyelid opening and is altered in conditions such as squamous metaplasia and dry eye. This alteration may result in instability of the tear film. CONCLU SION: The induction of mucin from the ocular surface may facilitate the stability of the tear film, and increased knowledge may lead to the development of a new modality for the treatment of dry eye.
The ocular surface and tear film and their dysfunction in dry eye disease.
Rolando, M; Zierhut, M
2001-03-01
The ocular surface, tear film, lacrimal glands, and eyelids act as a functional unit to preserve the quality of the refractive surface of the eye and to resist injury and protect the eye against changing bodily and environmental conditions. Events that disturb the homeostasis of this functional unit can result in a vicious cycle of ocular surface disease. The tear film is the most dynamic structure of the functional unit, and its production and turnover is essential to maintaining the health of the ocular surface. Classically, the tear film is reported to be composed of three layers: the mucin, aqueous, and lipid layers. The boundaries and real thickness of such layers is still under discussion. A dysfunction of any of these layers can result in dry eye disease.
Dong, Nuo; Yang, Fan; Lin, Zhirong; Shang, Xumin; Li, Cheng
2014-01-01
Objective To explore meibomian gland dysfunction (MGD) may determine the severity of dry eye conditions in visual display terminal (VDT) workers. Methodology Prospective, case-control study carried out in China.106 eyes of 53 patients (VDT work time >4 hour per day) were recruited as the Long time VDT group; 80 eyes of 40 control subjects (VDT work time ≤4 hour per day) served as the Short time VDT group. A questionnaire of Ocular Surface Disease Index (OSDI) and multiple tests were performed. Three dry eye tests: tear film breakup time (BUT), corneal fluorescein staining, Schirmer I test; and three MGD parameters: lid margin abnormality score, meibum expression assessment (meibum score), and meibomian gland dropout degree (meiboscore) using Keratograph 5 M. Principal Findings OSDI and corneal fluorescein score were significantly higher while BUT was dramatically shorter in the long time VDT group than the short time VDT group. However, the average of Schirmer tear volumes was in normal ranges in both groups. Interestingly, the three MGD parameters were significantly higher in the long time VDT group than the short time one (P<0.0001). When 52 eyes with Schirmer <10 mm and 54 eyes with Schirmer ≥10 mm were separated from the long time VDT workers, no significant differences were found between the two subgroups in OSDI, fluorescein staining and BUT, as well as the three MGD parameters. All three MGD parameters were positively correlated with VDT working time (P<0.0001) and fluorescein scores (P<0.0001), inversely correlated with BUT (P<0.05), but not correlated with Schirmer tear volumes in the VDT workers. Conclusions Our findings suggest that a malfunction of meibomian glands is associated with dry eye patients in long term VDT workers with higher OSDI scores whereas some of those patients presenting a normal tear volume. PMID:25144638
Lee, Sang Yeop; Han, Soo Jung; Nam, Sang Min; Yoon, Sang Chul; Ahn, Ji Min; Kim, Tae-Im; Kim, Eung Kweon; Seo, Kyoung Yul
2013-08-01
To compare concentrations of tear cytokines in 3 groups composed of Sjögren syndrome (SS) dry eye, non-Sjögren syndrome (non-SS) dry eye, and normal subjects. Correlations between ocular surface parameters and tear cytokines were also investigated. Prospective cross-sectional study. SS dry eye patients (n = 24; 40 eyes) were diagnosed with primary SS according to the criteria set by the American-European Consensus Group. Non-SS dry eye patients (n = 25; 40 eyes) and normal subjects (n = 21; 35 eyes) were also enrolled. Tear concentrations of interleukin (IL)-17, IL-6, IL-10, IL-4, IL-2, interferon γ (IFN-γ), and tumor necrosis factor α (TNF-α) were measured by a multiplex immunobead assay. Ocular Surface Disease Index (OSDI), tear film breakup time (TBUT), Schirmer I test, and fluorescein staining scores were obtained from dry eye patients. All cytokine levels except for IL-2 were highest in the SS group, followed by non-SS dry eye group and control subjects. Concentrations of IL-17, TNF-α, and IL-6 were significantly different among the 3 groups (IL-17: SS > control P < .001, non-SS > control P = .042, SS > non-SS P < .001; TNF-α: SS > control P = .006, non-SS > control P = .034, SS > non-SS P = .029; IL-6: SS > control P = .002, non-SS > control P = .032, SS > non-SS P = .002). IL-17 was significantly correlated with TBUT (R = -0.22, P = .012) and Schirmer I test (R = -0.36, P = .027) scores in the SS group. IL-6 was significantly correlated only with TBUT (R = -0.38, P = .02) in the non-SS group. Differences in tear cytokine levels and correlation patterns between SS dry eye and non-SS dry eye patients suggest the involvement of different inflammatory processes as causes of dry eye syndrome. Copyright © 2013 Elsevier Inc. All rights reserved.
Oral omega-6 essential fatty acid treatment in contact lens associated dry eye.
Kokke, Karolien H; Morris, Judith A; Lawrenson, John G
2008-06-01
Symptoms of dry eye are commonly reported in contact lens wearers and are a frequent cause of non-tolerance. The purpose of the present study is to evaluate the effects of oral treatment with particular omega-6 fatty acids in the form of evening primrose oil (EPO) on subjective symptoms, ocular surface signs and tear film characteristic in patients with contact lens associated dry eye. The study design was randomised, double-masked and placebo controlled. 76 female soft contact lens wearers were treated for 6 months with either EPO or placebo (olive oil). Subjects underwent three examinations (baseline, 3 and 6 months). At each examination subjects were given a questionnaire relating to lens comfort and dry eye symptoms and underwent a series of tests of tear film characteristics (tear meniscus height, break-up time), meibomian gland function (lipid layer thickness and quality) and ocular surface parameters (hyperaemia and staining). The EPO group showed a significant improvement in the specific symptom of 'dryness' at 3 and 6 months (p<0.01) and also a significant improvement in overall lens comfort at 6 months (p<0.01). Tear meniscus height was increased in the EPO group at 6 months relative to baseline (p<0.01), although all other objective signs were unchanged. This study provides evidence for a beneficial effect of particular orally administered omega-6 fatty acids in alleviating dry eye symptoms and improving overall lens comfort in patients suffering from contact lens associated dry eye.
Oral Omega-3 Fatty Acid Supplementation for Laser In Situ Keratomileusis-Associated Dry Eye.
Goyal, Parul; Jain, Arun K; Malhotra, Chintan
2017-02-01
To determine the effect of oral omega-3 fatty acid (ω3FA) supplementation in laser in situ keratomileusis (LASIK)-associated dry eye. In this prospective, open-label study, patients undergoing LASIK were randomized to receive either 1.2 g/d of a triglyceride formulation of oral ω3FA (treatment group) or 400 mg/d vitamin E (control group) for 1 week before and continued for 12 weeks after surgery. Ocular surface disease index, tear breakup time, ocular surface staining, and Schirmer scores were evaluated and compared preoperatively and at 3 months after LASIK. The study included 30 patients in each group. All parameters were comparable at baseline. Ocular surface disease index scores increased comparably in both groups (1.9 ± 0.6 increase in the treatment group; 2.8 ± 0.5 in the control group) (P = 0.267). Compared with baseline levels, tear breakup time decreased significantly (P < 0.01) but comparably in both treatment (-2.3 ± 0.4 seconds decrease) and control (-3.5 ± 0.7 seconds decrease) groups (P = 0.105). More eyes in the control group (43.4%) had conjunctival staining with Lissamine green at 3 months compared with the treatment group (14%) (P = 0.009). The Schirmer score at 3 months was higher (P = 0.003) in the treatment group (30.5 ± 0.90 mm) than in the control group (25.7 ± 1.3 mm) with a increase of 5.9 ± 1.3 mm from baseline in the treatment group and a decrease of 1.5 ± 1.2 mm in the control group. Supplementation with ω3FA in patients undergoing LASIK had a positive influence on tear secretion, whereas tear film stability remained unaffected when compared with the control group.
Dynamics and function of the tear film in relation to the blink cycle.
Braun, R J; King-Smith, P E; Begley, C G; Li, Longfei; Gewecke, N R
2015-03-01
Great strides have recently been made in quantitative measurements of tear film thickness and thinning, mathematical modeling thereof and linking these to sensory perception. This paper summarizes recent progress in these areas and reports on new results. The complete blink cycle is used as a framework that attempts to unify the results that are currently available. Understanding of tear film dynamics is aided by combining information from different imaging methods, including fluorescence, retroillumination and a new high-speed stroboscopic imaging system developed for studying the tear film during the blink cycle. During the downstroke of the blink, lipid is compressed as a thick layer just under the upper lid which is often released as a narrow thick band of lipid at the beginning of the upstroke. "Rippling" of the tear film/air interface due to motion of the tear film over the corneal surface, somewhat like the flow of water in a shallow stream over a rocky streambed, was observed during lid motion and treated theoretically here. New mathematical predictions of tear film osmolarity over the exposed ocular surface and in tear breakup are presented; the latter is closely linked to new in vivo observations. Models include the effects of evaporation, osmotic flow through the cornea and conjunctiva, quenching of fluorescence, tangential flow of aqueous tears and diffusion of tear solutes and fluorescein. These and other combinations of experiment and theory increase our understanding of the fluid dynamics of the tear film and its potential impact on the ocular surface. Copyright © 2014 Elsevier Ltd. All rights reserved.
Dynamics and function of the tear film in relation to the blink cycle
Braun, R.J.; King-Smith, P.E.; Begley, C.G.; Li, Longfei; Gewecke, N.R.
2014-01-01
Great strides have recently been made in quantitative measurements of tear film thickness and thinning, mathematical modeling thereof and linking these to sensory perception. This paper summarizes recent progress in these areas and reports on new results. The complete blink cycle is used as a framework that attempts to unify the results that are currently available. Understanding of tear film dynamics is aided by combining information from different imaging methods, including fluorescence, retroillumination and a new high-speed stroboscopic imaging system developed for studying the tear film during the blink cycle. During the downstroke of the blink, lipid is compressed as a thick layer just under the upper lid which is often released as a narrow thick band of lipid at the beginning of the upstroke. “Rippling” of the tear film/air interface due to motion of the tear film over the corneal surface, somewhat like the flow of water in a shallow stream over a rocky streambed, was observed during lid motion and treated theoretically here. New mathematical predictions of tear film osmolarity over the exposed ocular surface and in tear breakup are presented; the latter is closely linked to new in vivo observations. Models include the effects of evaporation, osmotic flow through the cornea and conjunctiva, quenching of fluorescence, tangential flow of aqueous tears and diffusion of tear solutes and fluorescein. These and other combinations of experiment and theory increase our understanding of the fluid dynamics of the tear film and its potential impact on the ocular surface. PMID:25479602
Antimicrobial Compounds in Tears
McDermott, Alison M.
2013-01-01
The tear film coats the cornea and conjunctiva and serves several important functions. It provides lubrication, prevents drying of the ocular surface epithelia, helps provide a smooth surface for refracting light, supplies oxygen and is an important component of the innate defense system of the eye providing protection against a range of potential pathogens. This review describes both classic antimicrobial compounds found in tears such as lysozyme and some more recently identified such as members of the cationic antimicrobial peptide family and surfactant protein-D as well as potential new candidate molecules that may contribute to antimicrobial protection. As is readily evident from the literature review herein, tears, like all mucosal fluids, contain a plethora of molecules with known antimicrobial effects. That all of these are active in vivo is debatable as many are present in low concentrations, may be influenced by other tear components such as the ionic environment, and antimicrobial action may be only one of several activities ascribed to the molecule. However, there are many studies showing synergistic/additive interactions between several of the tear antimicrobials and it is highly likely that cooperativity between molecules is the primary way tears are able to afford significant antimicrobial protection to the ocular surface in vivo. In addition to effects on pathogen growth and survival some tear components prevent epithelial cell invasion and promote the epithelial expression of innate defense molecules. Given the protective role of tears a number of scenarios can be envisaged that may affect the amount and/or activity of tear antimicrobials and hence compromise tear immunity. Two such situations, dry eye disease and contact lens wear, are discussed here. PMID:23880529
Self-Sustained Mode-3 Tear Controls Dynamics of Narrow Retreating Subduction Zones
NASA Astrophysics Data System (ADS)
Munch, J.; Gerya, T.; Ueda, K.
2017-12-01
The Caribbean oroclinal basin exhibits several narrow retreating slabs in an oceanic domain. The slabs show a curved shape associated to a bent topography (trench). We propose that the curvature of the topography depends on slab retreat mechanisms following mode-3 tearing at the edges of the slab (out of the plane fracture propagation). While first-order characteristics have been principally reproduced in self-sustained subduction initiation models (Gerya et al., 2015, Nature, 527, 221-225), the relevant observations have not been quantified and the exact mechanism is not understood. In this work, we study the long-term 3D evolution of narrowing oceanic subduction zones during retreat, and investigate the link between mode-3 tear and orocline formation. Numerical experiments are carried out with a thermo-mechanical 3D finite-difference code. To allow the observation of developing topography, the precise location of the internal surface and its evolution by material diffusion is tracked. Retreating subduction is facilitated via a strong age contrast between a young lithosphere window enclosed by shear zones and the surrounding lithosphere. By varying the length and thickness of the shear zones and location of the age transition, the influence of these parameters on the tearing process and the development of topography is assessed. Experiments trigger subduction initiation and slab retreat via fracture zone collapse and spontaneous paired mode-3 tear propagation within the oceanic plate interior. Narrow retreating subducting slabs form as a natural result of the spontaneous paired tearing process. A curved trench forms along with slab retreat. Topography evolution and tearing trajectory appear to be dependent on the initial shear zones and young window dimensions. We also note a strong narrowing of the slab during the retreat (several tens of kilometers over 800 km of retreat). Overall, results indicate that narrowing of retreating slabs is a self-consistent consequence of tear propagation dynamics. This plate tearing mechanism may control dynamics of other narrow retreating subduction zones worldwide.
Bozkurt, Murat; Unlu, Serhan; Cay, Nurdan; Apaydin, Nihal; Dogan, Metin
2014-10-01
The anatomic and the kinematical relationships between the femur and the tibia have been previously examined in both normal and diseased knees. However, less attention has been directed to the effect of these relationships on the meniscal diseases. Therefore, we aimed to investigate the impact of femorotibial incongruence on both lateral and medial meniscal tears. A total of 100 images obtained from MRI of 100 patients (39 males and 61 females) were included in the study. Diameters of the medial and the lateral femoral condyles, thicknesses of the menisci, and diameters of the medial and the lateral tibial articular surfaces were measured. The medial meniscus tear was detected in 40 (40 %) patients. However, no lateral meniscus tear was found. Significant relationships were found between the diameters of the posterior medial femoral condyle and the medial tibial superior articular surface and between the diameters of the posterior lateral femoral condyle and the lateral tibial superior articular surface. The mean values for the diameter of the medial condyle of the femur, the lateral condyle of the femur, the medial superior articular surface of the tibia, and the lateral superior articular surface of the tibia were found to be significantly higher in cases with meniscus tear compared to cases without meniscus tear. However, no significant difference was present regarding the thicknesses of the medial and the lateral menisci. A positive relationship between the diameter of the posterior medial femoral condyle and the tibial medial superior articular surface was found in cases with (n = 40) (r (2) = 0.208, p = 0.003) and without tear (n = 60) (r (2) = 0.182, p = 0.001). In addition, a significant positive relationship was found between the diameter of the posterior medial femoral condyle and the medial tibial superior articular surface in cases with and without tear. The impact of femorotibial incongruence on the medial meniscus tear is important for the understanding of the lesions.
NASA Astrophysics Data System (ADS)
Zhao, Xiaoye; Tan, Caiwang; Meng, Shenghao; Chen, Bo; Song, Xiaoguo; Li, Liqun; Feng, Jicai
2018-03-01
Fiber laser welding-brazing of 1-mm-thick AZ31B Mg alloys to 1.5-mm-thick copper (T2) with Mg-based filler was performed in a lap configuration. The weld appearance, interfacial microstructure and mechanical properties were investigated with different heat inputs. The results indicated that processing windows for optimizing appropriate welding parameters were relatively narrow in this case. Visually acceptable joints with certain strength were achieved at appropriate welding parameters. The maximum tensile-shear fracture load of laser-welded-brazed Mg/Cu joint could reach 1730 N at the laser power of 1200 W, representing 64.1% joint efficiency relative to AZ31Mg base metal. The eutectic structure (α-Mg + Mg2Cu) and Mg-Cu intermetallic compound was observed at the Mg/Cu interface, and Mg-Al-Cu ternary intermetallic compound were identified between intermetallics and eutectic structure at high heat input. All the joints fractured at the Mg-Cu interface. However, the fracture mode was found to differ. For laser power of 1200 W, the surface was characterized by tearing edge, while that with poor joint strength was almost dominated by smooth surface or flat tear pattern.
Dual interferometer for dynamic measurement of corneal topography
NASA Astrophysics Data System (ADS)
Micali, Jason D.; Greivenkamp, John E.
2016-08-01
The cornea is the anterior most surface of the eye and plays a critical role in vision. A thin fluid layer, the tear film, coats the outer surface of the cornea and serves to protect, nourish, and lubricate the cornea. At the same time, the tear film is responsible for creating a smooth continuous surface, where the majority of refraction takes place in the eye. A significant component of vision quality is determined by the shape of the cornea and stability of the tear film. A dual interferometer system for measuring the dynamic corneal topography is designed, built, verified, and qualified by testing on human subjects. The system consists of two coaligned simultaneous phase-shifting polarization-splitting Twyman-Green interferometers. The primary interferometer measures the surface of the tear film while the secondary interferometer tracks the absolute position of the cornea, which provides enough information to reconstruct the absolute shape of the cornea. The results are high-resolution and high-accuracy surface topography measurements of the in vivo tear film and cornea that are captured at standard camera frame rates.
Tear Film Osmolarity in Subjects with Acute Allergic Rhinoconjunctivitis
NITODA, EIRINI; LAVARIS, ANASTASIOS; LAIOS, KONSTANTINOS; ANDROUDI, SOPHIA; KALOGEROPOULOS, CHRIS D; TSATSOS, MICHAEL; DAMASKOS, CHRISTOS; GARMPIS, NIKOLAOS; MOSCHOS, MARILITA M
2018-01-01
Background/Aim: Acute allergic rhinoconjuctivitis is the most common form of ocular allergies. The pathogenetic mechanisms are based on an immunoglobulin E (IgE)-mediated hypersensitivity reaction. On the other hand, tear osmolarity has been suggested to be an index of ocular surface damage and inflammation. These data were the motive to investigate the levels of tear osmolarity in subjects with acute allergic rhinoconjuctivitis, before and after administration of artificial tears. Patients and Methods: Forty-five subjects with acute allergic rhinoconjuctivitis were randomly divided into three groups, based on the type of artificial tears that they received: Group A (Thera tears), Group B (Wet therapy) and Group C (Tears Naturale free). The eye drops were administered six times a day for 60 days and all subjects underwent grading of subjective symptoms and clinical examination at baseline and at the end of the treatment. Results: The diagnosis of severe eye disease, which was based on ocular surface disease index (OSDI; Allergan, Inc, Irvine, CA, USA) and tear osmolarity values, concerned all patients at baseline. Although the administration of artificial tears significantly ameliorated the symptoms and the ocular variables in all groups, the results were better in the first group. Tear osmolarity was strongly and negatively correlated with tear film breakup time (BUT) and Schirmer I test at 2 months. Contrariwise, symptoms were eliminated, when tear osmolarity was decreased. Conclusion: Acute allergic rhinoconjuctivitis is characterized by tear hyperosmolarity, which can be rehabilitated with the administration of hypotonic artificial tears. PMID:29475928
Albietz, Julie M; Lenton, Lee M
2004-01-01
To identify evidence-based, best practice strategies for managing the ocular surface and tear film before, during, and after laser in situ keratomileusis (LASIK). After a comprehensive review of relevant published literature, evidence-based recommendations for best practice management strategies are presented. Symptoms of ocular irritation and signs of dysfunction of the integrated lacrimal gland/ocular surface functional gland unit are common before and after LASIK. The status of the ocular surface and tear film before LASIK can impact surgical outcomes in terms of potential complications during and after surgery, refractive outcome, optical quality, patient satisfaction, and the severity and duration of dry eye after LASIK. Before LASIK, the health of the ocular surface should be optimized and patients selected appropriately. Dry eye before surgery and female gender are risk factors for developing chronic dry eye after LASIK. Management of the ocular surface during LASIK can minimize ocular surface damage and the risk of adverse outcomes. Long-term management of the tear film and ocular surface after LASIK can reduce the severity and duration of dry eye symptoms and signs. Strategies to manage the integrated ocular surface/lacrimal gland functional unit before, during, and after LASIK can optimize outcomes. As problems with the ocular surface and tear film are relatively common, attention should focus on the use and improvement of evidence-based management strategies.
Phototoxic effects of an operating microscope on the ocular surface and tear film.
Hwang, Hyung Bin; Kim, Hyun Seung
2014-01-01
We evaluated light exposure-induced dry eye syndrome by investigating the phototoxic effects of an operating microscope on the ocular surface and tear film in rabbits. Sixty eyes of 30 rabbits were divided into 3 groups based on the intensity of light exposure received from an operating microscope: Control group, no exposure to light; group A, 40,000-lx intensity for 30 minutes; and group B, 100,000-lx intensity for 30 minutes. To evaluate the potential damage to the ocular surface and tear film, Schirmer tests, rose bengal staining, and conjunctival impression cytology were performed before the light exposure and at 1, 3, and 5 days afterward. In addition, the expression of interleukin 1-beta was analyzed in tear samples. The expression of mucin 5AC was evaluated using immunofluorescence staining, and periodic acid-Schiff staining was conducted on conjunctival tissues. Corneal and conjunctival tissues were observed by means of electron microscopy. Potential damage to the ocular surface and tear film was found in the light-exposed groups as evidenced by decreased aqueous tear production, devitalized corneal and conjunctival epithelial cells, squamous metaplasia of conjunctival epithelial cells, decreased conjunctival goblet cell density, decreased expression of mucin 5AC, ultrastructural cellular damage to corneal and conjunctival tissues, and increased interleukin 1-beta expression in tears. This damage was more noticeable in group B than in group A (P < 0.05). Light exposure from an operating microscope had phototoxic effects on the ocular surface and tear film in this in vivo experiment. These changes seemed to intensify as the intensity of the light increased. Therefore, excessive light exposure during ophthalmic procedures could be a pathogenic factor in dry eye syndrome after a surgery is performed.
Isolation of the ocular surface to treat dysfunctional tear syndrome associated with computer use.
Yee, Richard W; Sperling, Harry G; Kattek, Ashballa; Paukert, Martin T; Dawson, Kevin; Garcia, Marcie; Hilsenbeck, Susan
2007-10-01
Dysfunctional tear syndrome (DTS) associated with computer use is characterized by mild irritation, itching, redness, and intermittent tearing after extended staring. It frequently involves foreign body or sandy sensation, blurring of vision, and fatigue, worsening especially at the end of the day. We undertook a study to determine the effectiveness of periocular isolation using microenvironment glasses (MEGS) alone and in combination with artificial tears in alleviating the symptoms and signs of dry eye related to computer use. At the same time, we evaluated the relative ability of a battery of clinical tests for dry eye to distinguish dry eyes from normal eyes in heavy computer users. Forty adult subjects who used computers 3 hours or more per day were divided into dry eye sufferers and controls based on their scores on the Ocular Surface Disease Index (OSDI). Baseline scores were recorded and ocular surface assessments were made. On four subsequent visits, the subjects played a computer game for 30 minutes in a controlled environment, during which one of four treatment conditions were applied, in random order, to each subject: 1) no treatment, 2) artificial tears, 3) MEGS, and 4) artificial tears combined with MEGS. Immediately after each session, subjects were tested on: a subjective comfort questionnaire, tear breakup time (TBUT), fluorescein staining, lissamine green staining, and conjunctival injection. In this study, a significant correlation was found between cumulative lifetime computer use and ocular surface disorder, as measured by the standardized OSDI index. The experimental and control subjects were significantly different (P<0.05) in the meibomian gland assessment and TBUT; they were consistently different in fluorescein and lissamine green staining, but with P>0.05. Isolation of the ocular surface alone produced significant improvements in comfort scores and TBUT and a consistent trend of improvement in fluorescein staining and lissamine green staining. Isolation plus tears produced a significant improvement in lissamine green staining. The subjective comfort inventory and the TBUT test were most effective in distinguishing between the treatments used. Computer users with ocular surface complaints should have a detailed ocular surface examination and, if symptomatic, they can be effectively treated with isolation of the ocular surface, artificial tears therapy, and effective environmental manipulations.
Antimicrobial compounds in tears.
McDermott, Alison M
2013-12-01
The tear film coats the cornea and conjunctiva and serves several important functions. It provides lubrication, prevents drying of the ocular surface epithelia, helps provide a smooth surface for refracting light, supplies oxygen and is an important component of the innate defense system of the eye providing protection against a range of potential pathogens. This review describes both classic antimicrobial compounds found in tears such as lysozyme and some more recently identified such as members of the cationic antimicrobial peptide family and surfactant protein-D as well as potential new candidate molecules that may contribute to antimicrobial protection. As is readily evident from the literature review herein, tears, like all mucosal fluids, contain a plethora of molecules with known antimicrobial effects. That all of these are active in vivo is debatable as many are present in low concentrations, may be influenced by other tear components such as the ionic environment, and antimicrobial action may be only one of several activities ascribed to the molecule. However, there are many studies showing synergistic/additive interactions between several of the tear antimicrobials and it is highly likely that cooperativity between molecules is the primary way tears are able to afford significant antimicrobial protection to the ocular surface in vivo. In addition to effects on pathogen growth and survival some tear components prevent epithelial cell invasion and promote the epithelial expression of innate defense molecules. Given the protective role of tears a number of scenarios can be envisaged that may affect the amount and/or activity of tear antimicrobials and hence compromise tear immunity. Two such situations, dry eye disease and contact lens wear, are discussed here. Copyright © 2013 Elsevier Ltd. All rights reserved.
Yuksel Elgin, Cansu; Iskeleli, Guzin; Aydin, Ovgu
2018-06-01
To investigate changes in tear and ocular surface of patients with keratoconus using rigid gas permeable contact lenses (RGPCL) and compare them against keratoconus patients who were not using lenses as well as a control group of healthy subjects. 24 keratoconus patients using RGPCL (Group 1) 22 patients who were not using lenses (Group 3) and 21 healthy subjects (Group 3) were included in the study. Subjective complaints about the subjects' eyes have been investigated using the ocular-surface disease index (OSDI). After the control of best-corrected visual acuity, anterior chamber and fundus examinations were performed. Schirmer (p-value=0.01) and tear break up mean comparison tests (p-value=0.002) revealed significant differences across different groups but tear osmolarity analysis did not (p-value >0.05). Oxford and OSDI scores were compatible with Schirmer and tear break up test comparisons. (for both p-value=0.001) Moreover, no statistical differences were seen in impression cytology measures between groups. (p-value >0.05) CONCLUSIONS: The erosion in the tear film stability is in line with the erosion in the ocular surface epithelium. Taking into account the statistical indifference between the impression cytology measures across groups, the break up time differences may be attributed to the collagen destruction in tear. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Effect of lipid-based dry eye supplements on the tear film in wearers of eye cosmetics.
Wang, Michael T M; Cho, Irene Sung Hee; Jung, Soo Hee; Craig, Jennifer P
2017-08-01
To compare the effects on tear film parameters and contamination in cosmetic eyeliner wearers, after single application of two lipid-based dry eye treatments: a lipid-containing lubricant eye drop and a phospholipid liposomal spray. Fifty participants were enrolled in a prospective, randomised, paired-eye, investigator-masked trial. Pencil eyeliner (Body Shop ® Crayon Eye Definer) was applied to the upper eyelid periocular skin of both eyes, anterior to the lash line. Baseline tear film quality was assessed fifteen minutes after eyeliner application. A lubricant drop (Systane ® Balance) was then applied to one eye (randomised), and liposomal spray (Tears Again ® ) to the contralateral eye. Tear film contamination, lipid layer grade, non-invasive tear film break-up time and tear evaporation rate were evaluated fifteen minutes post-treatment and compared to pre-treatment values. Pre-treatment measurements did not differ between eyes assigned to lubricant drop and liposomal spray. Tear film contamination was observed in a greater proportion of eyes following both treatments (both p<0.05), with no significant difference between treatments (p=0.41). Both treatments improved lipid layer thickness (both p≤0.01), but effected no significant change in non-invasive tear film break-up time or tear evaporation rate (all p>0.05). Changes in tear film parameters did not differ between treatments (all p>0.05). Both the lipid-containing lubricant eye drop and phospholipid liposomal spray result in clinically apparent tear film contamination in eyeliner cosmetic wearers. Although both treatments effected an increase in lipid layer thickness, neither displayed clinical efficacy in improving tear film stability. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Coupling Osmolarity Dynamics within Human Tear Film on an Eye-Shaped Domain
NASA Astrophysics Data System (ADS)
Li, Longfei; Braun, R. J.; Driscoll, T. A.; Henshaw, W. D.; Banks, J. W.; King-Smith, P. E.
2013-11-01
The concentration of ions in the tear film (osmolarity) is a key variable in understanding dry eye symptoms and disease. We derived a mathematical model that couples osmolarity (treated as a single solute) and fluid dynamics within the tear film on a 2D eye-shaped domain. The model concerns the physical effects of evaporation, surface tension, viscosity, ocular surface wettability, osmolarity, osmosis and tear fluid supply and drainage. We solved the governing system of coupled nonlinear PDEs using the Overture computational framework developed at LLNL, together with a new hybrid time stepping scheme (using variable step BDF and RKC) that was added to the framework. Results of our numerical simulations show good agreement with existing 1D models (for both tear film and osmolarity dynamics) and provide new insight about the osmolarity distribution over the ocular surface during the interblink.
Partial supraspinatus tears are associated with tendon lengthening.
Farshad-Amacker, Nadja A; Buck, Florian M; Farshad, Mazda; Pfirrmann, Christian W A; Gerber, Christian
2015-02-01
Tendon tear may result in muscular retraction with the loss of contractile amplitude and strength of the rotator cuff muscles. Currently, neither a validated method of measuring supraspinatus tendon length nor normal values are known. It was therefore the purpose of this study to measure the normal length of the supraspinatus tendon and to determine whether partial tears are associated with changes in tendon length. MR examinations of 49 asymptomatic volunteers and 37 patients with arthroscopically proven, isolated partial tears of the supraspinatus tendon were compared. The ratio of the extramuscular tendon length to the distance between the footprint and the glenoid surface was calculated (TL/FG ratio). Tendon length measurements were taken by two independent readers at the bursal and articular surfaces at the anterior, the central and the posterior parts of the tendon. TL/FG ratios at the bursal surface of tendons with partial tears were significantly higher than those in the control group [anterior: 0.78 ± 0.20 vs. 0.66 ± 0.15 (p < 0.05); central: 0.61 ± 0.13 vs. 0.52 ± 0.10 (p < 0.05); posterior: 0.57 ± 0.15 vs. 0.52 ± 0.10 (p < 0.05)]. At the articular surface, differences were significant only anteriorly [0.60 ± 0.13, vs. 0.54 ± 0.10 (p < 0.05)]. A cut-off TL/FG ratio of 0.63 for measurements at the bursal surface in the center of the tendon achieved a sensitivity of 46 % and a specificity of 92 % for the identification of partial cuff tearing. A reproducible method for measurement of extramuscular supraspinatus tendon length is described. Partial tearing of the supraspinatus tendon is associated with significant tendon lengthening, suggesting failure in continuity, and this is most reliably measured on the bursal surface. III.
Ishii, Rie; Shimizu, Kimiya; Igarashi, Akihito; Kobashi, Hidenaga; Kamiya, Kazutaka
2015-01-01
To compare the influence of femtosecond lenticule extraction (FLEx) and small incision lenticule extraction (SMILE) on corneal nerve density and the ocular surface for equivalent degrees of correction of myopia. Sixty eyes of 30 patients (8 males and 22 females, mean age: 31.0 ± 6.0 years) were included in the study. The patients underwent FLEx in 1 eye and SMILE in the other eye by random assignment. Subbasal nerve density was measured using confocal microscopy preoperatively and at 1 week, 1 and 3 months, and 1 year postoperatively. Ocular surface parameters such as Schirmer's test results, tear film break-up time, and corneal sensation were performed preoperatively and at 1 and 3 months postoperatively. In the FLEx group, subbasal nerve density was 18,390 ± 6,090 µm/mm(2) preoperatively and 5,770 ± 3,490 µm/mm(2) at 1 year postoperatively (P < .001, Dunnett's test). In the SMILE group, subbasal nerve density was 16,810 ± 6,220 µm/mm(2) preoperatively and 11,870 ± 8,200 µm/mm(2) at 1 year postoperatively (P = .21). The decrease in corneal nerve density was significantly less after SMILE than after FLEx at all postoperative visits (Mann-Whitney U test, P < .05). FLEx resulted in a significant decrease in Schirmer's test results, tear film break-up time, and corneal sensation at all postoperative visits, whereas SMILE induced no significant changes in these parameters (P > .05). There was less damage to the sub-basal nerve plexus of the cornea and less effect on the ocular surface parameters after SMILE than after FLEx. Copyright 2015, SLACK Incorporated.
Randomized Trial of Desktop Humidifier for Dry Eye Relief in Computer Users.
Wang, Michael T M; Chan, Evon; Ea, Linda; Kam, Clifford; Lu, Yvonne; Misra, Stuti L; Craig, Jennifer P
2017-11-01
Dry eye is a frequently reported problem among computer users. Low relative humidity environments are recognized to exacerbate signs and symptoms of dry eye, yet are common in offices of computer operators. Desktop USB-powered humidifiers are available commercially, but their efficacy for dry eye relief has not been established. This study aims to evaluate the potential for a desktop USB-powered humidifier to improve tear-film parameters, ocular surface characteristics, and subjective comfort of computer users. Forty-four computer users were enrolled in a prospective, masked, randomized crossover study. On separate days, participants were randomized to 1 hour of continuous computer use, with and without exposure to a desktop humidifier. Lipid-layer grade, noninvasive tear-film breakup time, and tear meniscus height were measured before and after computer use. Following the 1-hour period, participants reported whether ocular comfort was greater, equal, or lesser than that at baseline. The desktop humidifier effected a relative difference in humidity between the two environments of +5.4 ± 5.0% (P < .001). Participants demonstrated no significant differences in lipid-layer grade and tear meniscus height between the two environments (all P > .05). However, a relative increase in the median noninvasive tear-film breakup time of +4.0 seconds was observed in the humidified environment (P < .001), which was associated with a higher proportion of subjects reporting greater comfort relative to baseline (36% vs. 5%, P < .001). Even with a modest increase in relative humidity locally, the desktop humidifier shows potential to improve tear-film stability and subjective comfort during computer use.Trial registration no: ACTRN12617000326392.
Tear Film Osmolarity in Subjects with Acute Allergic Rhinoconjunctivitis.
Nitoda, Eirini; Lavaris, Anastasios; Laios, Konstantinos; Androudi, Sophia; Kalogeropoulos, Chris D; Tsatsos, Michael; Damaskos, Christos; Garmpis, Nikolaos; Moschos, Marilita M
2018-01-01
Acute allergic rhinoconjuctivitis is the most common form of ocular allergies. The pathogenetic mechanisms are based on an immunoglobulin E (IgE)-mediated hypersensitivity reaction. On the other hand, tear osmolarity has been suggested to be an index of ocular surface damage and inflammation. These data were the motive to investigate the levels of tear osmolarity in subjects with acute allergic rhinoconjuctivitis, before and after administration of artificial tears. Forty-five subjects with acute allergic rhinoconjuctivitis were randomly divided into three groups, based on the type of artificial tears that they received: Group A (Thera tears), Group B (Wet therapy) and Group C (Tears Naturale free). The eye drops were administered six times a day for 60 days and all subjects underwent grading of subjective symptoms and clinical examination at baseline and at the end of the treatment. The diagnosis of severe eye disease, which was based on ocular surface disease index (OSDI; Allergan, Inc, Irvine, CA, USA) and tear osmolarity values, concerned all patients at baseline. Although the administration of artificial tears significantly ameliorated the symptoms and the ocular variables in all groups, the results were better in the first group. Tear osmolarity was strongly and negatively correlated with tear film breakup time (BUT) and Schirmer I test at 2 months. Contrariwise, symptoms were eliminated, when tear osmolarity was decreased. Acute allergic rhinoconjuctivitis is characterized by tear hyperosmolarity, which can be rehabilitated with the administration of hypotonic artificial tears. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.
Jung, Ji Won; Park, Si Yoon; Kim, Jin Sun; Kim, Eung Kweon; Seo, Kyoung Yul; Kim, Tae-Im
2016-08-01
To determine the effects of clinical variables, including age, sex, history of refractive or cataract surgery, contact lens use, and ocular surface and meibomian gland parameters on the lipid layer thickness (LLT) in normal subjects and patients with dry eye syndrome (DES). A total of 64 normal subjects and 326 patients with DES were enrolled, and they underwent measurements of LLT with a LipiView interferometer and tear meniscus height using optical coherence tomography, tear film break-up time (TBUT) determination, ocular surface staining, Schirmer's test, examination of the lid margins and meibomian glands, and assessment using the Ocular Surface Disease Index (OSDI). In normal subjects, the median (range) LLT was 67 (33-100) nm, and age was the only factor that was significantly associated with LLT (β = 0.678, P = 0.028). In patients with DES, the median (range) LLT was 84 (20-100) nm, and 79.0% of the participants fulfilled the diagnostic criteria for meibomian gland dysfunction (MGD). In a multivariate analysis, increased age and female sex were significantly related to increased LLT (β = 0.282, P = 0.005 and β = 11.493, P < 0.001), and hypersecretory MGD and lid margin inflammation were independently associated with increased LLT (β = 11.299, P = 0.001 and β = 12.747, P = 0.001). Lipid layer thickness measurements using a new interferometer are significantly affected by demographic factors such as age, sex, ocular surgical history, and MGD type. Therefore, all of these factors must be considered in the diagnosis of ocular surface diseases.
Association Between Contact Lens Discomfort and Pre-lens Tear Film Kinetics.
Guillon, Michel; Dumbleton, Kathryn A; Theodoratos, Panagiotis; Wong, Stephanie; Patel, Kishan; Banks, Gaidig; Patel, Trisha
2016-08-01
The relationship between contact lens wettability and comfort has been extensively evaluated; however, a direct correlation between the characteristics of the pre-lens tear film and the symptoms associated with contact lens discomfort has yet to be established. In addition, there is relatively limited knowledge relating to the entire tear film kinetics during the inter-blink period in contact lens wearers. The purpose of this analysis was to identify the characteristics of the pre-lens tear film kinetics that may be associated with the symptoms of contact lens discomfort. The study population comprised 202 soft (hydrogel and silicone hydrogel) contact lens wearers attending pre-screening visits at the OTG-i research clinic. All participants completed the Ocular Surface Disease Index (OSDI) questionnaire and the tear film was quantified via post hoc, masked analysis of high definition digital Tearscope videos recorded at the visit. The tear film kinetics of the least symptomatic wearers (OSDI lowest quintile scores, n = 45) were compared to the tear film kinetics of the most symptomatic wearers (OSDI highest quintile scores, n = 43). The hypothesis tested was that the tear film kinetics of asymptomatic wearers were better than tear film kinetics of symptomatic wearers. The distribution of lens types worn was as follows: Daily Disposable 46.5%, 1-Month Replacement 39.6%, and 2-Week Replacement 13.6%. 48.2% of lenses were silicone hydrogel and 51.8% hydrogel. Symptomatic wearers had a shorter break-up time (4.7 s vs. 6.0 s; p = 0.003), lesser surface coverage by the tear film during the interblink period (95.1% vs. 98.5%; p < 0.001) and greater surface exposure at the time of the blink (9.4% vs. 3.9%; p = 0.001). The current study demonstrated that the tear film kinetics of asymptomatic and symptomatic contact lens wearers were different, the findings supporting the hypothesis of poorer tear film kinetics for symptomatic than asymptomatic wearers in a general contact lens wearing population.
Guerini, H; Fermand, M; Godefroy, D; Feydy, A; Chevrot, A; Morvan, G; Gault, N; Drapé, J L
2012-02-01
The supraspinatus tendon is composed of 5 different layers consisting of intertwining bundles. On a front portion of the tendon, the layers become coated bundles which insert on the trochanter. At the insertion, the superficial or bursal surface of the tendon corresponding to the tendon fibers in contact with the subacromial bursa can be distinguished from the deep surface corresponding to the fibers in contact with the glenohumeral joint. A tendon tear may involve partial or total disruption of the tendon fibers and is called full-thickness tear if it affects the entire tendon, and partial-thickness tear if it involves only part of the tendon. Partial-thickness tears of the supraspinatus tendon include lesions of the superficial, deep and central surface or tendon delamination.A contrast enhanced examination requires injection of contrast agent into the joint (arthrography followed by computed tomography (CT) or magnetic resonance imaging (MRI)) to study the deep surface, and injection into the subacromial bursa (bursography followed by CT) to study the superficial surface. MRI and ultrasound (US) examination allow the study of these different tendon layers without the use of contrast agent (which is not possible at CT).
Oral antioxidant therapy for marginal dry eye.
Blades, K J; Patel, S; Aidoo, K E
2001-07-01
To assess the efficacy of an orally administered antioxidant dietary supplement for managing marginal dry eye. A prospective, randomised, placebo controlled trial with cross-over. Eye Clinic, Department of Vision Sciences, Glasgow Caledonian University. Forty marginal dry eye sufferers composed of 30 females and 10 males (median age 53 y; range 38-69 y). Baseline assessments were made of tear volume sufficiency (thread test), tear quality (stability), ocular surface status (conjunctival impression cytology) and dry eye symptoms (questionnaire). Each subject was administered courses of active treatment, placebo and no treatment, in random order for 1 month each and results compared to baseline. Tear stability and ocular surface status were significantly improved following active treatment (P<0.05). No changes from baseline were detected following administration of placebo and no treatment (P>0.05). Absolute increase in tear stability correlated with absolute change in goblet cell population density. Tear volume was not improved following any treatment period and dry eye symptom responses were subject to placebo effect. Oral antioxidants improved both tear stability and conjunctival health, although it is not yet understood whether increased ocular surface health mediates increased tear stability or vice versa. This study was supported by a PhD scholarship funded by the Department of Vision Sciences, Glasgow Caledonian University, Scotland. Antioxidant supplements and placebos were kindly donated by Vitabiotics.
Ng, Alex L K; Choy, Bonnie N K; Chan, Tommy C Y; Wong, Ian Y H; Lai, Jimmy S M; Mok, Mo Yin
2017-07-01
To compare tear osmolarity (TO) and other dry eye parameters in rheumatoid arthritis (RA) patients with or without secondary Sjogren syndrome (sSS). Consecutive patients with RA were divided into a sSS group and no-sSS group using conventional diagnostic criteria by rheumatologists using symptomatology, Schirmer test score, and anti-Ro or anti-La autoantibody status. The TO, Ocular Surface Disease Index, dry eye disease (DED) parameters [such as tear breakup time (TBUT) and corneal staining score] and the systemic inflammatory markers [erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP)] were compared. Correlation analyses between TO and the DED parameters and inflammatory markers were also performed. A total of 42 cases with mean age 54.8 ± 12.3 were included, with 12 patients (29%) having sSS and 30 (71%) without sSS. TO was increased in both groups (329 ± 20 and 319 ± 25 mOsm/L, respectively), but no statistically significant difference was found between the 2 groups (P = 0.126). RA with sSS had significantly shorter TBUT, higher corneal staining score, and ESR CRP levels (P < 0.05). TO did not correlate with the Schirmer test score, but had significant positive correlations with age, corneal staining score, ESR, and CRP levels, and a significant negative correlation with TBUT. TO was increased in RA patients with or without sSS. There was no significant correlation between TO and the Schirmer test score, and the physician could not use TO to diagnose sSS. However, TO correlated well with both DED parameters (TBUT and corneal staining score) and systemic inflammatory markers (ESR and CRP).
Tear-Film Evaporation Rate from Simultaneous Ocular-Surface Temperature and Tear-Breakup Area.
Dursch, Thomas J; Li, Wing; Taraz, Baseem; Lin, Meng C; Radke, Clayton J
2018-01-01
A corneal heat-transfer model is presented to quantify simultaneous measurements of fluorescein tear-breakup area (TBA) and ocular-surface temperature (OST). By accounting for disruption of the tear-film lipid layer (TFLL), we report evaporation rates through lipid-covered tear. The modified heat-transfer model provides new insights into evaporative dry eye. A quantitative analysis is presented to assess human aqueous tear evaporation rate (TER) through intact TFLLs from simultaneous in vivo measurement of time-dependent infrared OST and fluorescein TBA. We interpret simultaneous OST and TBA measurements using an extended heat-transfer model. We hypothesize that TBAs are ineffectively insulated by the TFLL and therefore exhibit higher TER than does that for a well-insulting TFLL-covered tear. As time proceeds, TBAs increase in number and size, thereby increasing the cornea area-averaged TER and decreasing OST. Tear-breakup areas were assessed from image analysis of fluorescein tear-film-breakup video recordings and are included in the heat-transfer description of OST. Model-predicted OSTs agree well with clinical experiments. Percent reductions in TER of lipid-covered tear range from 50 to 95% of that for pure water, in good agreement with literature. The physical picture of noninsulating or ruptured TFLL spots followed by enhanced evaporation from underlying cooler tear-film ruptures is consistent with the evaporative-driven mechanism for local tear rupture. A quantitative analysis is presented of in vivo TER from simultaneous clinical measurement of transient OST and TBA. The new heat-transfer model accounts for increased TER through expanding TBAs. Tear evaporation rate varies strongly across the cornea because lipid is effectively missing over tear-rupture troughs. The result is local faster evaporation compared with nonruptured, thick lipid-covered tear. Evaporative-driven tear-film ruptures deepen to a thickness where fluorescein quenching commences and local salinity rises to uncomfortable levels. Mitigation of tear-film rupture may therefore reduce dry eye-related symptoms.
In Vitro Spoilation of Silicone-Hydrogel Soft Contact Lenses in a Model-Blink Cell.
Peng, Cheng-Chun; Fajardo, Neil P; Razunguzwa, Trust; Radke, Clayton J
2015-07-01
We developed an in vitro model-blink cell that reproduces the mechanism of in vivo fouling of soft contact lenses. In the model-blink cell, model tear lipid directly contacts the lens surface after forced aqueous rupture, mirroring the pre-lens tear-film breakup during interblink. Soft contact lenses are attached to a Teflon holder and immersed in artificial tear solution with protein, salts, and mucins. Artificial tear-lipid solution is spread over the air/tear interface as a duplex lipid layer. The aqueous tear film is periodically ruptured and reformed by withdrawing and reinjecting tear solution into the cell, mimicking the blink-rupture process. Fouled deposits appear on the lenses after cycling, and their compositions and spatial distributions are subsequently analyzed by optical microscopy, laser ablation electrospray ionization mass spectrometry, and two-photon fluorescence confocal scanning laser microscopy. Discrete deposit (white) spots with an average size of 20 to 300 μm are observed on the studied lenses, confirming what is seen in vivo and validating the in vitro model-blink cell. Targeted lipids (cholesterol) and proteins (albumin from bovine serum) are identified in the discrete surface deposits. Both lipid and protein occur simultaneously in the surface deposits and overlap with the white spots observed by optical microscopy. Additionally, lipid and protein penetrate into the bulk of tested silicone-hydrogel lenses, likely attributed to the bicontinuous microstructure of oleophilic silicone and hydrophilic polymer phases of the lens. In vitro spoilation of soft contact lenses is successfully achieved by the model-blink cell confirming the tear rupture/deposition mechanism of lens fouling. The model-blink cell provides a reliable laboratory tool for screening new antifouling lens materials, surface coatings, and care solutions.
Essa, Laika; Laughton, Deborah; Wolffsohn, James S
2018-02-01
To assess dry eye treatment with four preservative-free dry eye artificial tear treatments to facilitate evidence-based prescribing. A randomised, single masked crossover trial of Clinitas Soothe, Hyabak, Tears Again and TheraTears artificial tears was conducted on 50 symptomatic dry eye patients, aged 60.8±14.2years. At baseline and after trialling each treatment for 4 weeks, signs and symptoms were assessed using the Ocular Surface Disease Index (OSDI), non-invasive tear break-up time, fluorescein tear break-up time, tear meniscus height (TMH), Phenol Red test, lid-parallel conjunctival folds (LIPCOF), ocular surface staining, and lipid layer grading and osmolarity (baseline visit only). OSDI (p=0.002), LIPCOF (p=0.014) and conjunctival staining (p<0.001) significantly improved from baseline, however, the impact of each dry eye treatment on ocular symptoms and signs was similar. Clinitas Soothe and Hyabak were preferred by 34%/30% of participants, but only subjective comparison with the other drops influenced this choice. TheraTears was preferred (by 24%) by those with a lower baseline tear volume (p=0.01) and Tears Again (by 12%) by those with a thinner baseline lipid layer (p=0.04). The treatment that afforded the greatest improvement in clinical signs did not consistently match each individual's preferred treatment. If prescribed to a general dry eye population, the artificial tears performed similarly, improving symptoms and conjunctival signs. However, osmolarity balanced artificial tears were the preferred treatment in individuals with low baseline tear volume and lipisomal spray for individuals with a baseline lipid layer deficiency. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Effects of electron cyclotron current drive on the evolution of double tearing mode
NASA Astrophysics Data System (ADS)
Sun, Guanglan; Dong, Chunying; Duan, Longfang
2015-09-01
The effects of electron cyclotron current drive (ECCD) on the double tearing mode (DTM) in slab geometry are investigated by using two-dimensional compressible magnetohydrodynamics equations. It is found that, mainly, the double tearing mode is suppressed by the emergence of the secondary island, due to the deposition of driven current on the X-point of magnetic island at one rational surface, which forms a new non-complete symmetric magnetic topology structure (defined as a non-complete symmetric structure, NSS). The effects of driven current with different parameters (magnitude, initial time of deposition, duration time, and location of deposition) on the evolution of DTM are analyzed elaborately. The optimal magnitude or optimal deposition duration of driven current is the one which makes the duration of NSS the longest, which depends on the mutual effect between ECCD and the background plasma. Moreover, driven current introduced at the early Sweet-Parker phase has the best suppression effect; and the optimal moment also exists, depending on the duration of the NSS. Finally, the effects varied by the driven current disposition location are studied. It is verified that the favorable location of driven current is the X-point which is completely different from the result of single tearing mode.
Dilisio, Matthew F.; Miller, Lindsay R.; Higgins, Laurence D.
2014-01-01
Arthroscopic transtendinous techniques for the arthroscopic repair of partial-thickness, articular-surface rotator cuff tears offer the advantage of minimizing the disruption of the patient's remaining rotator cuff tendon fibers. In addition, double-row fixation of full-thickness rotator cuff tears has shown biomechanical advantages. We present a novel method combining these 2 techniques for transtendon, double-row, transosseous-equivalent arthroscopic repair of partial-thickness, articular-surface rotator cuff tears. Direct visualization of the reduction of the retracted articular tendon layer to its insertion on the greater tuberosity is the key to the procedure. Linking the medial-row anchors and using a double-row construct provide a stable repair that allows early shoulder motion to minimize the risk of postoperative stiffness. PMID:25473606
Dilisio, Matthew F; Miller, Lindsay R; Higgins, Laurence D
2014-10-01
Arthroscopic transtendinous techniques for the arthroscopic repair of partial-thickness, articular-surface rotator cuff tears offer the advantage of minimizing the disruption of the patient's remaining rotator cuff tendon fibers. In addition, double-row fixation of full-thickness rotator cuff tears has shown biomechanical advantages. We present a novel method combining these 2 techniques for transtendon, double-row, transosseous-equivalent arthroscopic repair of partial-thickness, articular-surface rotator cuff tears. Direct visualization of the reduction of the retracted articular tendon layer to its insertion on the greater tuberosity is the key to the procedure. Linking the medial-row anchors and using a double-row construct provide a stable repair that allows early shoulder motion to minimize the risk of postoperative stiffness.
NASA Astrophysics Data System (ADS)
Huang, Jinxin; Clarkson, Eric; Kupinski, Matthew; Rolland, Jannick P.
2014-03-01
The prevalence of Dry Eye Disease (DED) in the USA is approximately 40 million in aging adults with about $3.8 billion economic burden. However, a comprehensive understanding of tear film dynamics, which is the prerequisite to advance the management of DED, is yet to be realized. To extend our understanding of tear film dynamics, we investigate the simultaneous estimation of the lipid and aqueous layers thicknesses with the combination of optical coherence tomography (OCT) and statistical decision theory. In specific, we develop a mathematical model for Fourier-domain OCT where we take into account the different statistical processes associated with the imaging chain. We formulate the first-order and second-order statistical quantities of the output of the OCT system, which can generate some simulated OCT spectra. A tear film model, which includes a lipid and aqueous layer on top of a rough corneal surface, is the object being imaged. Then we further implement a Maximum-likelihood (ML) estimator to interpret the simulated OCT data to estimate the thicknesses of both layers of the tear film. Results show that an axial resolution of 1 μm allows estimates down to nanometers scale. We use the root mean square error of the estimates as a metric to evaluate the system parameters, such as the tradeoff between the imaging speed and the precision of estimation. This framework further provides the theoretical basics to optimize the imaging setup for a specific thickness estimation task.
Non-invasive pre-lens tear film assessment with high-speed videokeratoscopy.
Llorens-Quintana, Clara; Mousavi, Maryam; Szczesna-Iskander, Dorota; Iskander, D Robert
2018-02-01
To evaluate the effect of two types of daily contact lenses (delefilcon A and omafilcon A) on the tear film and establish whether it is dependent on pre-corneal tear film characteristics using a new method to analyse high-speed videokeratoscopy recordings, as well as to determine the sensitivity of the method in differentiating between contact lens materials on eye. High-speed videokeratoscopy recordings were analysed using a custom made automated algorithm based on a fractal dimension approach that provides a set of parameters directly related to tear film stability. Fifty-four subjects participated in the study. Baseline measurements, in suppressed and natural blinking conditions, were taken before subjects were fitted with two different daily contact lenses and after four hours of contact lens wear. The method for analysing the stability of the tear film provides alternative parameters to the non-invasive break up time to assess the quality of the pre-corneal and pre-lens tear film. Both contact lenses significantly decreased the quality of the tear film in suppressed and natural blinking conditions (p<0.001). The utilised method was able to distinguish between contact lens materials on eye in suppressed blinking conditions. The pre-corneal tear film characteristics were not correlated with the decrease in pre-lens tear film quality. High-speed videokeratoscopy equipped with an automated method to analyse the dynamics of the tear film is able to distinguish between contact lens materials in vivo. Incorporating the assessment of pre-lens tear film to the clinical practice could aid improving contact lens fitting and understand contact lens comfort. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Effects of tear film dynamics on quality of vision.
Koh, Shizuka; Tung, Cynthia I; Inoue, Yasushi; Jhanji, Vishal
2018-06-15
The precorneal tear film is maintained by blinking and exhibits different phases in the tear cycle. The tear film serves as the most anterior surface of the eye and plays an important role as a first refractive component of the eye. Alterations in tear film dynamics may cause both vision-related and ocular surface-related symptoms. Although the optical quality associated with the tear film dynamics previously received little attention, objective measurements of optical quality using wavefront sensors have enabled us to quantify optical aberrations induced by the tear film. This has provided an objective method for assessing reduced optical quality in dry eye; thus, visual disturbances were included in the definition of dry eye disease in the 2007 Dry Eye Workshop report. In addition, sequential measurements of wavefront aberrations have provided us with valuable insights into the dynamic optical changes associated with tear film dynamics. This review will focus on the current knowledge of the mechanisms of wavefront variations that are caused by different aspects of tear film dynamics: specifically, quality, quantity and properties of the tear film, demonstrating the respective effects of dry eye, epiphora and instillation of eye drops on the quality of vision. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Dry eye symptoms are increased in mice deficient in phospholipid transfer protein (PLTP).
Setälä, Niko L; Metso, Jari; Jauhiainen, Matti; Sajantila, Antti; Holopainen, Juha M
2011-05-01
In the tear fluid the outermost part facing the tear-air interface is composed of lipids preventing evaporation of the tears. Phospholipid transfer protein (PLTP) mediates phospholipid transfer processes between serum lipoproteins and is also a normal component of human tears. To study whether PLTP plays any functional role in tear fluid we investigated PLTP-deficient mice, applying functional and morphologic analyses under normal housing and experimentally induced dry eye conditions. Aqueous tear fluid production, corneal epithelial morphology, barrier function, and occludin expression were assessed. In mice with a full deficiency of functional PLTP enhanced corneal epithelial damage, increased corneal permeability to carboxyfluorescein, and decreased corneal epithelial occludin expression were shown. These pathologic signs were worsened by experimentally induced dry eye both in wild-type and PLTP knock-out mice. Deficiency in the production of tear PLTP in mice is accompanied by corneal epithelial damage, a feature that is typical in human dry eye syndrome (DES). To complement animal experiments we collected tear fluid from human dry eye patients as well as healthy control subjects. Increased tear fluid PLTP activity was observed among DES patients. In conclusion, the presence of PLTP in tear fluid appears to be essential for maintaining a healthy and functional ocular surface. Increased PLTP activity in human tear fluid in DES patients suggests an ocular surface protective role for this lipid transfer protein. Copyright © 2011 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.
Hahnel, Elisabeth; Blume-Peytavi, Ulrike; Trojahn, Carina; Kottner, Jan
2017-11-13
Geriatric patients are affected by a range of skin conditions and dermatological diseases, functional limitations and chronic diseases. Skin problems are highly prevalent in elderly populations. Aim of this study was to investigate possible associations between health, functional and cutaneous variables in aged long-term care residents. This observational, cross-sectional, descriptive prevalence study was conducted in a random sample of 10 institutional long-term care facilities in Berlin. In total, n = 223 residents were included. Demographic and functional characteristics, xerosis cutis, incontinence associated dermatitis, pressure ulcers and skin tears were assessed. Stratum corneum hydration, transepidermal water loss, skin surface pH and skin temperature were measured. Data analysis was descriptive and explorative. To explore possible bivariate associations, a correlation matrix was created. The correlation matrix was also used to detect possible collinearity in the subsequent regression analyses. Mean age (n = 223) was 83.6 years, 67.7% were female. Most residents were affected by xerosis cutis (99.1%; 95% CI: 97.7% - 100.0%). The prevalence of pressure ulcers was 9.0% (95% CI: 5.0% - 13.0%), of incontinence associated dermatitis 35.4% (95% CI: 29.9% - 42.2%) and of skin tears 6.3% (95% CI: 3.2% - 9.5%). Biophysical skin parameters were not associated with overall care dependency, but with age and skin dryness. In general, skin dryness and measured skin barrier parameters were associated between arms and legs indicating similar overall skin characteristics of the residents. Prevalence of xerosis cutis, pressure ulcers and skin tears were high, indicating the load of these adverse skin conditions in this population. Only few associations of demographic characteristics, skin barrier impairments and the occurrence of dry skin, pressure ulcers, skin tears and incontinence-associated dermatitis have been detected, that might limit the diagnostic value of skin barrier parameters in this population. Overall, the measured skin barrier parameters seem to have limited diagnostic value for the reported skin conditions except xerosis cutis. This study is registered at https://clinicaltrials.gov/ct2/show/NCT02216526 . Registration date: 8th November 2014.
Dynamic measurement of the corneal tear film with a Twyman-Green interferometer
NASA Astrophysics Data System (ADS)
Micali, Jason D.; Greivenkamp, John E.; Primeau, Brian C.
2014-07-01
An interferometer for measuring dynamic properties of the in vivo tear film on the human cornea has been developed. The system is a near-infrared instantaneous phase-shifting Twyman-Green interferometer. The laser source is a 785 nm solidstate laser; the system has been carefully designed and calibrated to ensure that the system operates at eye safe levels. Measurements are made over a 6 mm diameter on the cornea. Successive frames of interferometric height measurements are combined to produce movies showing both the quantitative and qualitative changes in the topography of the tear film surface and structure. To date, measurement periods of up to 120 seconds at 28.6 frames per second have been obtained. Several human subjects have been examined using this system, demonstrating a surface height resolution of 25 nm and spatial resolution of 6 μm. Examples of features that have been observed in these in preliminary studies of the tear film include: post-blink disruption, evolution, and stabilization of the tear film; tear film artifacts generated by blinking; tear film evaporation and break-up; and the propagation of foreign objects in the tear film. This paper discusses the interferometer design and presents results from in vivo measurements.
Dynamic measurement of the corneal tear film with a Twyman-Green interferometer
NASA Astrophysics Data System (ADS)
Micali, Jason D.; Greivenkamp, John E.; Primeau, Brian C.
2015-05-01
An interferometer for measuring dynamic properties of the in vivo tear film on the human cornea has been developed. The system is a near-infrared instantaneous phase-shifting Twyman-Green interferometer. The laser source is a 785 nm solid-state laser, and the system has been carefully designed and calibrated to ensure that the system operates at eye-safe levels. Measurements are made over a 6 mm diameter on the cornea. Successive frames of interferometric height measurements are combined to produce movies showing both the quantitative and qualitative changes in the topography of the tear film surface and structure. To date, measurement periods of up to 120 s at 28.6 frames per second have been obtained. Several human subjects have been examined using this system, demonstrating a surface height resolution of 25 nm and spatial resolution of 6 μm. Examples of features that have been observed in these preliminary studies of the tear film include postblink disruption, evolution, and stabilization of the tear film; tear film artifacts generated by blinking; tear film evaporation and breakup; and the propagation of foreign objects in the tear film. This paper discusses the interferometer design and presents results from in vivo measurements.
NASA Astrophysics Data System (ADS)
Yamada, K.; Endo, T.; Imai, H.; Kido, M.; Jeong, H.; Ohno, Y.
2016-03-01
We have developed the point-of-care therapeutic drug monitoring kit based on Raman Spectroscopy of tear fluid. In this study, we were examined a soft substrate for an optimal lattice based on nanoimprint lithography using cyclo-olefin polymer to improve the sensitivity for measuring drug concentration in tear fluid. This is photonics crystal which is one of the nano-photonics based device was fabricated. Target is Sodium Phenobarbital which is an anticonvulsant agent. We show the effectiveness of Surface Enhanced Raman Spectroscopy of tear fluid with soft substrate for point-of-care therapeutic drug monitoring.
Gao, Shaohui; Li, Saiqun; Liu, Liangping; Wang, Yong; Ding, Hui; Li, Lili; Zhong, Xingwu
2014-01-01
Purpose To characterize the early ocular-surface changes or tear inflammatory-mediators levels following small-incision lenticule extraction (ReLEx smile) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK). Methods Forty-seven myopic subjects were recruited for this prospective study. Fifteen underwent ReLEx smile and thirty-two underwent FS-LASIK. Corneal fluorescein (FL) staining, tear break-up time (TBUT), Schirmer I test (SIT), ocular surface disease index (OSDI) and central corneal sensitivity were evaluated in all participants. Tears were collected and analyzed for interleukin-6 (IL-6), tumor necrosis factor-α (TNF-α), nerve growth factor (NGF) and intercellular adhesion molecule-1 (ICAM-1) levels using multiplex magnetic beads. All measurements were preformed preoperatively and 1 day, 1 week, 1 month and 3 months postoperatively. Results FL scores in ReLEx smile group were lower than those of FS-LASIK group 1 week postoperatively (P = 0.010). Compared to the FS-LASIK group, longer TBUT were observed in ReLEx smile group 1 month (P = 0.029) and 3 months (P = 0.045) postoperatively. No significant differences were found in tear secretion for the two groups (P>0.05). OSDI scores were higher in FS-LASIK group 1 month after surgery (P = 0.020). Higher central corneal sensitivity was observed in ReLEx smile group 1 week, 1 month and 3 months (P<0.05) postoperatively. Compared to FS-LASIK group, lower and faster recovery of IL-6 and NGF levels in tears was observed in ReLEx smile group postoperatively (P<0.05). Tears TNF-α and ICAM-1 concentrations were not significantly different between the two groups at any follow-up time (P>0.05). Moreover, IL-6 and NGF levels correlated with ocular surface changes after ReLEx smile or FS-LASIK. Conclusions In the early postoperative period, ReLEx smile results in milder ocular surface changes than FS-LASIK. Furthermore, the tear inflammatory mediators IL-6 and NGF may play a crucial role in the ocular surface healing process following ReLEx smile and FS-LASIK. PMID:25211490
Gao, Shaohui; Li, Saiqun; Liu, Liangping; Wang, Yong; Ding, Hui; Li, Lili; Zhong, Xingwu
2014-01-01
To characterize the early ocular-surface changes or tear inflammatory-mediators levels following small-incision lenticule extraction (ReLEx smile) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK). Forty-seven myopic subjects were recruited for this prospective study. Fifteen underwent ReLEx smile and thirty-two underwent FS-LASIK. Corneal fluorescein (FL) staining, tear break-up time (TBUT), Schirmer I test (SIT), ocular surface disease index (OSDI) and central corneal sensitivity were evaluated in all participants. Tears were collected and analyzed for interleukin-6 (IL-6), tumor necrosis factor-α (TNF-α), nerve growth factor (NGF) and intercellular adhesion molecule-1 (ICAM-1) levels using multiplex magnetic beads. All measurements were preformed preoperatively and 1 day, 1 week, 1 month and 3 months postoperatively. FL scores in ReLEx smile group were lower than those of FS-LASIK group 1 week postoperatively (P = 0.010). Compared to the FS-LASIK group, longer TBUT were observed in ReLEx smile group 1 month (P = 0.029) and 3 months (P = 0.045) postoperatively. No significant differences were found in tear secretion for the two groups (P>0.05). OSDI scores were higher in FS-LASIK group 1 month after surgery (P = 0.020). Higher central corneal sensitivity was observed in ReLEx smile group 1 week, 1 month and 3 months (P<0.05) postoperatively. Compared to FS-LASIK group, lower and faster recovery of IL-6 and NGF levels in tears was observed in ReLEx smile group postoperatively (P<0.05). Tears TNF-α and ICAM-1 concentrations were not significantly different between the two groups at any follow-up time (P>0.05). Moreover, IL-6 and NGF levels correlated with ocular surface changes after ReLEx smile or FS-LASIK. In the early postoperative period, ReLEx smile results in milder ocular surface changes than FS-LASIK. Furthermore, the tear inflammatory mediators IL-6 and NGF may play a crucial role in the ocular surface healing process following ReLEx smile and FS-LASIK.
Svitova, Tatyana F; Lin, Meng C
2016-07-01
This review summarizes the current state of knowledge regarding interfacial properties of very complex biological colloids, specifically, human meibum and tear lipids, and their interactions with proteins similar to the proteins found in aqueous part of human tears. Tear lipids spread as thin films over the surface of tear-film aqueous and play crucial roles in tear-film stability and overall ocular-surface health. The vast majority of papers published to date report interfacial properties of meibum-lipid monolayers spread on various aqueous sub-phases, often containing model proteins, in Langmuir trough. However, it is well established that natural human ocular tear lipids exist as multilayered films with a thickness between 30 and 100nm, that is very much disparate from 1 to 2nm thick meibum monolayers. We employed sessile-bubble tensiometry to study the dynamic interfacial and rheological properties of reconstituted multilayered human tear-lipid films. Small amounts (0.5-1μg) of human tear lipids were deposited on an air-bubble surface to produce tear-lipid films in thickness range 30-100nm corresponding to ocular lipid films. Thus, we were able to overcome major Langmuir-trough method limitations because ocular tear lipids can be safely harvested only in minute, sub-milligram quantities, insufficient for Langmuir through studies. Sessile-bubble method is demonstrated to be a versatile tool for assessing conventional synthetic surfactants adsorption/desorption dynamics at an air-aqueous solution interface. (Svitova T., Weatherbee M., Radke C.J. Dynamics of surfactant sorption at the air/water interface: continuous-flow tensiometry. J. Colloid Interf. Sci. 2003;261:1170-179). The augmented flow-sessile-bubble setup, with step-strain relaxation module for dynamic interfacial rheological properties and high-precision syringe pump to generate larger and slow interfacial area expansions-contractions, was developed and employed in our studies. We established that this method is uniquely suitable for examination of multilayered lipid-film interfacial properties. Recently it was compellingly proven that chemical composition of human tear lipids extracted from whole tears is substantially different from that of meibum lipids. To be exact, healthy human tear lipids contain 8-16% of polar lipids, similar to lung lipids, and they are mostly double-tailed phospholipids, with C16 and longer alkyl chains. Rationally, one would assume that the results obtained for meibum lipids, devoid of surface-active components such as phospholipids, and, above all, in a form of monolayers, are not pertinent or useful for elucidating behavior and stability of an averaged 60-nm thick ocular tear-lipid films in vivo. The advantage of sessile-bubble technique, specifically, using a small amount of lipids required to attain multilayered films, unlocks the prospect of evaluating and comparing the interfacial properties of human tear lipids collected from a single individual, typically 100-150μg. This is in sharp contrast with several milligrams of lipids that would be required to build equally thick films for Langmuir-trough experiments. The results of our studies provided in-depth understanding of the mechanisms responsible for properties and stability of human tear-lipid films in vivo. Here we summarize recent publications and our latest findings regarding human tear-lipid interfacial properties, their chemical composition, and their interaction with model proteins mimicking the proteins found in human tear-aqueous phase. Published by Elsevier B.V.
Surface Properties of Squalene/Meibum Films and NMR Confirmation of Squalene in Tears
Ivanova, Slavyana; Tonchev, Vesselin; Yokoi, Norihiko; Yappert, Marta C.; Borchman, Douglas; Georgiev, Georgi As.
2015-01-01
Squalene (SQ) possesses a wide range of pharmacological activities (antioxidant, drug carrier, detoxifier, hydrating, emollient) that can be of benefit to the ocular surface. It can come in contact with human meibum (hMGS; the most abundant component of the tear film lipid layer) as an endogenous tear lipid or from exogenous sources as eyelid sebum or pharmaceuticals. The aims of this study were to determine (i) if SQ is in tear lipids and (ii) its influence on the surface properties of hMGS films. Heteronuclear single quantum correlation NMR confirmed 7 mol % SQ in Schirmer’s strips extracts. The properties of SQ/hMGS pseudo-binary films at the air/water interface were studied with Langmuir surface balance, stress-relaxation dilatational rheology and Brewster angle microscopy. SQ does not possess surfactant properties. When mixed with hMGS squalene (i) localized over the layers’ thinner regions and (ii) did not affect the film pressure at high compression. Therefore, tear SQ is unlikely to instigate dry eye, and SQ can be used as a safe and “inert” ingredient in formulations to protect against dry eye. The layering of SQ over the thinner film regions in addition to its pharmacological properties could contribute to the protection of the ocular surface. PMID:26370992
Release of Membrane-associated Mucins from Ocular Surface Epithelia
Blalock, Timothy D.; Spurr-Michaud, Sandra J.; Tisdale, Ann S.; Gipson, Ilene K.
2008-01-01
Purpose Three membrane-associated mucins (MAMs)—MUC1, MUC4 and MUC16—are expressed at the ocular surface epithelium. Soluble forms of MAMs are detected in human tears, but the mechanisms of their release from the apical cells are unknown. The purpose of this study was to identify physiologic agents that induce ocular surface MAM release. Methods An immortalized human corneal-limbal epithelial cell line (HCLE) expressing the same MAMs as native tissue was used. An antibody specific to MUC16’s cytoplasmic tail was developed to confirm that only the extracellular domain is released into the tear fluid or culture media. Effects of agents that have been shown to be present in tears or are implicated in release/shedding of MAMs in other epithelia (neutrophil elastase, tumor necrosis factor (TNF), TNF-α-converting enzyme, and matrix metalloproteinases-7 and –9) were assessed on HCLE cells. HCLE cell surface proteins were biotinylated to measure efficiency of induced MAM release and surface restoration. Effects of induced release on surface barrier function were measured by rose bengal dye penetrance. Results MUC16 in tears and in HCLE-conditioned medium lacked the cytoplasmic tail. TNF induced release of MUC1, MUC4, and MUC16 from the HCLE surface. Matrix metalloproteinase-7 and neutrophil elastase induced release of MUC16 but not MUC1 or MUC4. Neutrophil elastase removed 68% of MUC16—78% of which was restored to the HCLE cell surface 24 hours after release. Neutrophil elastase-treated HCLE cells showed significantly reduced rose bengal dye exclusion. Conclusions Results suggest that extracellular domains of MUC1, 4, and 16 can be released from the ocular surface by agents present in tears. Neutrophil elastase and TNF present in higher amounts in dry eye patients’ tears may cause MAM release—allowing rose bengal staining. PMID:18436821
Patterson, Matthew; Vogel, Hans J; Prenner, Elmar J
2017-03-01
The tear film lipid layer is formed on the anterior surface of the eye, functioning as a barrier to excess evaporation and foreign particles, while also providing stability to the tear film. The lipid layer is organized into a polar lipid layer consisting of phospholipids, ceramides, and free fatty acids that act as a surfactant to a non-polar multilayer of wax and cholesterol esters. Due to shear forces from eye movement and the compression and expansion of blinking, the tear lipids are under constant stress. However, tear film is able to resist immediate rupture and remains intact over multiple blinks. This work aimed to better understand the lateral organization of selected tear film polar lipids. The polar lipid biomimetic studied here consisted of dipalmitoyl phosphatidylcholine (DPPC), dipalmitoyl phosphatidylethanolamine (DPPE), palmitoyl glucosylceramide (PGC), and palmitoyl sphingomyelin (PSM). Surface pressure-area isocycles mimicked blinking and films were visualized by Brewster angle microscopy (BAM). All lipid systems formed relatively reversible films as indicated by limited hysteresis. However, pure DPPC and PSM films experienced greater changes in lipid packing upon compression and expansion compared to pure PGC and DPPE. This suggests that the driving force behind maintaining the lateral organization of the polar lipids from tear film may be the hydrogen bonding propensities of the head groups. Additionally, isocycles of films containing DPPC, DPPE, and PGC mixtures exhibited evidence for reversible multilayer formation or folding. This was supported by 3D analysis of structures that formed during compression but reintegrated back into the bulk lipid film during expansion near the in vitro tear film surface pressure of the open eye. Therefore, the polar lipids of tear film may be directly involved in preventing film rupture during a blink. Copyright © 2016 Elsevier B.V. All rights reserved.
A parametric study of the drift-tearing mode using an extended-magnetohydrodynamic model
King, Jacob R.; Kruger, S. E.
2014-10-24
The linear, collisional, constant-ψ drift-tearing mode is analyzed for different regimes of the plasma-β, ion-skin-depth parameter space with an unreduced, extended-magnetohydrodynamic model. Here, new dispersion relations are found at moderate plasma β and previous drift-tearing results are classified as applicable at small plasma β.
Computed tear film and osmolarity dynamics on an eye-shaped domain
Li, Longfei; Braun, Richard J.; Driscoll, Tobin A.; Henshaw, William D.; Banks, Jeffrey W.; King-Smith, P. Ewen
2016-01-01
The concentration of ions, or osmolarity, in the tear film is a key variable in understanding dry eye symptoms and disease. In this manuscript, we derive a mathematical model that couples osmolarity (treated as a single solute) and fluid dynamics within the tear film on a 2D eye-shaped domain. The model includes the physical effects of evaporation, surface tension, viscosity, ocular surface wettability, osmolarity, osmosis and tear fluid supply and drainage. The governing system of coupled non-linear partial differential equations is solved using the Overture computational framework, together with a hybrid time-stepping scheme, using a variable step backward differentiation formula and a Runge–Kutta–Chebyshev method that were added to the framework. The results of our numerical simulations provide new insight into the osmolarity distribution over the ocular surface during the interblink. PMID:25883248
Influence of driven current on resistive tearing mode in Tokamaks
NASA Astrophysics Data System (ADS)
Ma, Zhiwei; Wang, Sheng; Zhang, Wei
2016-10-01
Influence of driven current on the m / n = 2 / 1 resistive tearing mode is studied systematically using a three-dimensional toroidal MHD code (CLT). A uniform driven current with Gaussian distribution in the radial direction is imposed around the unperturbed rational surface. It is found that the driven current can locally modify the profiles of the current and safety factor, such that the tearing mode becomes linearly stable. The stabilizing effect increases with increase of the driven current Icd or decrease of its width δcd, unless an excessively large driven current reverses the magnetic shear near the rational surface and drives other instabilities such as double or triple tearing modes. The stabilizing effect can be negligible or becomes reversed if the maximum driven current density is not at the unperturbed rational surface. ITER-CN Program.
Alfawaz, Abdullah M; Algehedan, Saeed; Jastaneiah, Sabah S; Al-Mansouri, Samir; Mousa, Ahmed; Al-Assiri, Abdullah
2014-03-01
To evaluate the effect of punctal plug use in preventing dry eye after laser in situ keratomileusis (LASIK). A randomized clinical trial at a tertiary eye care center, Riyadh, Saudi Arabia. Participants underwent LASIK for myopia in both eyes and a lower punctal occlusion in one eye only while the other eye served as control. Both eyes received the same postoperative medications except for lubricant duration (subject eye: four times per day for one week; control eye: four times per day for 6 months). Participants were evaluated at 1 week, 2, and 6 months after surgery for signs and symptoms of dry eye. The main outcome measures were visual acuity; ocular surface parameters; and Ocular Surface Disease Index questionnaire. Seventy-eight eyes of 39 patients were included in this study. The Ocular Surface Disease Index scores of eyes with punctal plugs were better at all follow-up visits, and the differences between both eyes were statistically significant (1 week, p < 0.0001; 2 months, p < 0.0001; 6 months, p = 0.008). At the final follow-up visit, the percentage of normal eyes was higher in eyes with punctal plugs for all ocular surface parameters (Schirmer 1 test, 94.9%; tear breakup time, 77.8%; punctate epithelial keratitis score, 71.8%) compared to eyes without occlusion (Schirmer 1 test, 92.3%; tear breakup time, 58.3%; punctate epithelial keratitis score, 53.8%); however, such differences were not statistically significant. Punctal plug insertion after LASIK surgeries may minimize the need for frequent lubricant application and hence improve patient satisfaction.
Friedman, Neil J; Butron, Karla; Robledo, Nora; Loudin, James; Baba, Stephanie N; Chayet, Arturo
2016-01-01
Dry eye disease (DED), a chronic disorder affecting the tear film and lacrimal functional unit, is a widely prevalent condition associated with significant burden and unmet treatment needs. Since specific neural circuits play an important role in maintaining ocular surface health, microelectrical stimulation of these pathways could present a promising new approach to treating DED. This study evaluated the efficacy and safety of nasal electrical stimulation in patients with DED. This prospective, open-label, single-arm, nonrandomized pilot study included 40 patients with mild to severe DED. After undergoing two screening visits, enrolled subjects were provided with a nasal stimulation device and instructed to use it at home four times daily (or more often as needed). Follow-up assessments were conducted up to day 180. The primary efficacy endpoint was the difference between unstimulated and stimulated tear production quantified by Schirmer scores. Additional efficacy endpoints included change from baseline in corneal and conjunctival staining, symptoms evaluated on a Visual Analog Scale, and Ocular Surface Disease Index scores. Safety parameters included adverse event (AE) rates, visual acuity, intraocular pressure, slit-lamp biomicroscopy, indirect ophthalmoscopy, and endoscopic nasal examinations. Mean stimulated Schirmer scores were significantly higher than the unstimulated scores at all visits, and corneal and conjunctival staining and symptom scores from baseline to day 180 were significantly reduced. No serious device-related AEs and nine nonserious AEs (three device-related) were reported. Intraocular pressure remained stable and most subjects showed little or no change in visual acuity at days 30 and 180. No significant findings from other clinical examinations were noted. Neurostimulation of the nasolacrimal pathway is a safe and effective means of increasing tear production and reducing symptoms of dry eye in patients with DED.
Said, Azza Mohamed Ahmed; Farag, Mona Elsayed; Abdulla, Tarek Mohamed; Ziko, Othman Ali Othman; Osman, Wesam Mohamed
2016-01-01
AIM To evaluate the effect of punctal occlusion using thermosensitive (smart plug) versus silicone plug for management of aqueous deficient dry eye on corneal sensitivity, ocular surface health and tear film stability. METHODS A comparative prospective interventional case study included 45 patients with bilateral severe form of aqueous deficient dry eye. In each patient, the smart plug was inserted in the lower punctum of the right eye which was considered as study group 1 and silicone plug was inserted in the lower punctum of the left eye of the same patient which was considered as study group 2. All patients were subjected to careful history taking and questionnaire for subjective assessment of severity of symptoms. Corneal sensitivity, corneal fluorescein, rose bengal staining, Schirmer's I test, tear film break up time and conjunctival impression cytology were performed pre and 1, 3 and 6mo post plug insertion. RESULTS A statistically significant improvement in subjective and objective manifestations occurred following treatment with both types of plugs (P<0.01). The thermosensitive plug caused significant overall improvement, decrease in frequency of application of tear substitutes and improvement of conjunctival impression cytology parameters in the inserted side (P<0.01). Canaliculitis was reported in two eyes (4.4%) following punctal occlusion using thermosensitive plug (study group 1). Spontaneous plug loss occurred in 21 eyes (46.6%) in the silicone plug group (study group 2). CONCLUSION Improvement of subjective and objective manifestations of aqueous deficient dry eye occurs following punctal plug occlusion. Thermosensitive plug has good patient's compliance with fewer complications and lower rates of loss compared to the silicone plug. PMID:27990362
Evaporation and Hydrocarbon Chain Conformation of Surface Lipid Films
Sledge, Samiyyah M.; Khimji, Hussain; Borchman, Douglas; Oliver, Alexandria; Michael, Heidi; Dennis, Emily K.; Gerlach, Dylan; Bhola, Rahul; Stephen, Elsa
2016-01-01
Purpose The inhibition of the rate of evaporation (Revap) by surface lipids is relevant to reservoirs and dry eye. Our aim was to test the idea that lipid surface films inhibit Revap. Methods Revap were determined gravimetrically. Hydrocarbon chain conformation and structure were measured using a Raman microscope. Six 1-hydroxyl hydrocarbons (11–24 carbons in length) and human meibum were studied. Reflex tears were obtained from a 62-year-old male. Results The Raman scattering intensity of the lipid film deviated by about 7 % for hydroxyl lipids and varied by 21 % for meibum films across the entire film at a resolution of 5 µm2. All of the surface lipids were ordered. Revap of the shorter chain hydroxyl lipids were slightly (7%) but significantly lower compared with the longer chain hydroxyl lipids. Revap of both groups was essentially similar to that of buffer. A hydroxyl lipid film did not influence Revap over an estimated average thickness range of 0.69 to >6.9 µm. Revap of human tears and buffer with and without human meibum (34.4 µm thick) was not significantly different. Revap of human tears was not significantly different from buffer. Conclusions Human meibum and hydroxyl lipids, regardless of their fluidity, chain length, or thickness did not inhibit Revap of buffer or tears even though they completely covered the surface. It is unlikely that hydroxyl lipids can be used to inhibit Revap of reservoirs. Our data do not support the widely accepted (yet unconfirmed) idea that the tear film lipid layer inhibits Revap of tears. PMID:27395776
Long, Qin; Wang, Jing-Yi; Xu, Dong; Li, Ying
2017-01-01
To compare the corneal biomechanics of Sjögren's syndrome (SS) and non-SS dry eyes with Corneal Visualization Scheimpflug Technology (CorVis ST). Corneal biomechanics and tear film parameters, namely the Schirmer I test value, tear film break-up time (TBUT) and corneal staining score (CSS) were detected in 34 eyes of 34 dry eye patients with SS (SSDE group) and 34 dry eye subjects without SS (NSSDE group) using CorVis ST. The differences of the above parameters between the two groups were examined, and the relationship between corneal biomechanics and tear film parameters were observed. The differences in age, sex, intraocular pressure (IOP) and central corneal thickness (CCT) were not significant between the two groups ( P >0.05). The tear film parameters had significant differences between the SSDE group and NSSDE group (all P <0.05). Patients in the SSDE group had significantly lower A1-time and HC-time, but higher DA ( P =0.01, 0.02, and 0.02, respectively) compared with the NSSDE group. In the SSDE group, DA was negatively correlated with TBUT ( rho =-0.38, P =0.03); HC-time was negatively correlated with CSS ( rho =-0.43, P =0.02). In the NSSDE group, HC-time was again negatively correlated with CSS ( rho =-0.39, P =0.02). There are differences in corneal biomechanical properties between SSDE and NSSDE. The cornea of SSDE tends to show less "stiffness", as seen by a significantly shorter A1-time and HC-time, but larger DA, compared with the cornea of NSSDE. Biomechanical parameters can be influenced by different tear film parameters in both groups.
Kan, Akinori; Oshida, Midori; Oshida, Shigemi; Imada, Masato; Nakagawa, Takumi; Okinaga, Shuji
2010-01-12
Traumatic injury and surgical meniscectomy of a medial meniscus are known to cause subsequent knee osteoarthritis. However, the difference in the prevalence of osteoarthritis caused by the individual type of the medial meniscal tear has not been elucidated. The aim of this study was to investigate what type of tear is predominantly responsible for the degradation of articular cartilage in the medial compartment of knee joints. Five hundred and forty eight cadaveric knees (290 male and 258 female) were registered in this study. The average age of cadavers at death was 78.8 years old (range: 52-103 years). The knees were macroscopically examined and their medial menisci were classified into four groups according to types of tears: "no tear", "radial tear of posterior horn", "other types of tear" and "worn-out meniscus" groups. The severity of cartilage degradation in their medial compartment of knee joints was evaluated using the international cartilage repair society (ICRS) grading system. We statistically compared the ICRS grades among the groups using Mann-Whitney U test. The knees were assigned into the four groups: 416 "no tear" knees, 51 "radial tear of posterior horn" knees, 71 "other types of tear" knees, and 10 "worn-out meniscus" knees. The knees with substantial meniscal tears showed the severer ICRS grades of cartilage degradation than those without meniscal tears. In addition, the ICRS grades were significantly severer in the "radial tear of posterior horn" group than in the "other types of tear" group, suggesting that the radial tear of posterior horn in the medial meniscus is one of the risk factors for cartilage degradation of joint surface. We have clarified the relationship between the radial tear of posterior horn in the medial meniscus and the severer grade of cartilage degradation. This study indicates that the efforts should be made to restore the anatomical role of the posterior horn in keeping the hoop strain, when patients' physical activity levels are high and the tear pattern is simple enough to be securely sutured.
TFOS DEWS II Tear Film Report.
Willcox, Mark D P; Argüeso, Pablo; Georgiev, Georgi A; Holopainen, Juha M; Laurie, Gordon W; Millar, Tom J; Papas, Eric B; Rolland, Jannick P; Schmidt, Tannin A; Stahl, Ulrike; Suarez, Tatiana; Subbaraman, Lakshman N; Uçakhan, Omür Ö; Jones, Lyndon
2017-07-01
The members of the Tear Film Subcommittee reviewed the role of the tear film in dry eye disease (DED). The Subcommittee reviewed biophysical and biochemical aspects of tears and how these change in DED. Clinically, DED is characterized by loss of tear volume, more rapid breakup of the tear film and increased evaporation of tears from the ocular surface. The tear film is composed of many substances including lipids, proteins, mucins and electrolytes. All of these contribute to the integrity of the tear film but exactly how they interact is still an area of active research. Tear film osmolarity increases in DED. Changes to other components such as proteins and mucins can be used as biomarkers for DED. The Subcommittee recommended areas for future research to advance our understanding of the tear film and how this changes with DED. The final report was written after review by all Subcommittee members and the entire TFOS DEWS II membership. Copyright © 2017 Elsevier Inc. All rights reserved.
4A syndrome: ocular surface investigation in an Italian young patient.
Aragona, Pasquale; Rania, Laura; Roszkowska, Anna Maria; Puzzolo, Domenico; Micali, Antonio; Pisani, Antonina; Salzano, Giuseppina; Messina, Maria Francesca
2014-12-08
Allgrove's 4A syndrome determines ocular surface changes. This is the first report providing an up-to-dated analysis of the ocular surface in an affected patient. An 18-years-old male Caucasian patient, with a complex progressive gait disorder and adrenal insufficiency, was referred for ophthalmic evaluation, as part of the clinical assessment. He underwent the following tests: best corrected visual acuity, tear osmolarity, tear film break-up time (BUT), corneal fluorescein staining, Schirmer's I test, lid margin assessment, corneal sensitivity, in vivo corneal confocal microscopy, conjunctival impression cytology, tonometry and fundus exam. A dry eye condition was documented by the Schirmer's I test of 0 mm/5' in both eyes, accompanied by tear hyperosmolarity, mild meibomian gland dysfunction, reduced BUT, mucus filaments in the tear film and conjunctival epithelium metaplasic changes. The corneal confocal microscopy showed the presence of activated keratocytes, while the nerve pattern was normal. The dry eye in this patient appears to be due to tear aqueous deficiency and can be considered as part of the 4A syndrome. The decreased tear production, resulting from a deterioration of the autonomic innervation of the lacrimal glands rather than an impaired corneal innervation, can be considered as part of the systemic autonomic dysfunction present in this disease.
Cytokine and chemokine levels in tears from healthy subjects.
Carreño, Ester; Enríquez-de-Salamanca, Amalia; Tesón, Marisa; García-Vázquez, Carmen; Stern, Michael E; Whitcup, Scott M; Calonge, Margarita
2010-11-01
There is growing evidence for the existence of an 'immune tone' in normal tears. The aim of this study was to determine the levels of a large panel of cytokines and chemokines in tears obtained from healthy subjects. These levels can then serve as baseline values for comparison with patients suffering from ocular surface diseases. Nine healthy subjects participated in this study, and normal ocular surface health was documented by the results of a dry eye questionnaire, Schirmer strip wetting, and vital staining of the cornea. Four microliters of tears were collected from each eye and analysed separately with multiplex bead-based assays for the concentration of 30 cytokines and chemokines. Twenty-five cytokines/chemokines were detected. CCL11/Eotaxin1, GM-CSF, G-CSF, IFN-γ, IL-2, IL-3, IL-4, IL-5, IL-10, IL-13, IL-12p70, IL-15, CX3CL1/Fractalkine, TNF-α, epidermal growth factor, and CCL4/MIP-1β were present at 5-100 pg/ml. IL-1β, IL-6, IL-7A, CXCL8/IL-8, and CCL2/MCP-1 were present at 100-400 pg/ml. IL-1Ra, CXCL10/IP-10 and vascular endothelial growth factor were present at more than 1000 pg/ml. Multiplex bead-based assays are convenient for cytokine/chemokine detection in tears. Fracktalkine has been detected in human healthy tears for the first time. The knowledge of cytokine/chemokine concentrations in tears from normal subjects is an important reference for further comparison with patients suffering from ocular surface diseases. Variability in their levels can reflect a phenomenon of potential importance for the understanding of the ocular surface cytokine pattern. © 2010 The Authors. Journal compilation © 2010 Acta Ophthalmol.
Sebbag, Lionel; Thomasy, Sara M; Woodward, Andrew P; Knych, Heather K; Maggs, David J
2016-08-01
OBJECTIVES To determine, following oral administration of famciclovir, pharmacokinetic (PK) parameters for 2 of its metabolites (penciclovir and BRL42359) in plasma and tears of healthy cats so that famciclovir dosage recommendations for the treatment of herpetic disease can be optimized. ANIMALS 7 male domestic shorthair cats. PROCEDURES In a crossover study, each of 3 doses of famciclovir (30, 40, or 90 mg/kg) was administered every 8 or 12 hours for 3 days. Six cats were randomly assigned to each dosage regimen. Plasma and tear samples were obtained at predetermined times after famciclovir administration. Pharmacokinetic parameters were determined for BRL42359 and penciclovir by compartmental and noncompartmental methods. Pharmacokinetic-pharmacodynamic (PK-PD) indices were determined for penciclovir and compared among all dosage regimens. RESULTS Compared with penciclovir concentrations, BRL42359 concentrations were 5- to 11-fold greater in plasma and 4- to 7-fold greater in tears. Pharmacokinetic parameters and PK-PD indices for the 90 mg/kg regimens were superior to those for the 30 and 40 mg/kg regimens, regardless of dosing frequency. Penciclovir concentrations in tears ranged from 18% to 25% of those in plasma. Administration of 30 or 40 mg/kg every 8 hours achieved penciclovir concentrations likely to be therapeutic in plasma but not in tears. Penciclovir concentrations likely to be therapeutic in tears were achieved only with the two 90 mg/kg regimens. CONCLUSIONS AND CLINICAL RELEVANCE In cats, famciclovir absorption is variable and its metabolism saturable. Conversion of BRL42359 to penciclovir is rate limiting. The recommended dosage of famciclovir is 90 mg/kg every 12 hours for cats infected with feline herpesvirus.
Androgen deficiency and dry eye syndrome in the aging male.
Azcarate, Patrick M; Venincasa, Vincent D; Feuer, William; Stanczyk, Frank; Schally, Andrew V; Galor, Anat
2014-07-03
To evaluate the relationship between androgen levels and subjective and objective measures of dry eye syndrome (DES). A total of 263 male patients from the Miami Veterans Affairs Medical Center eye clinic aged ≥50 were recruited for this prospective cross-sectional study. Patients completed Dry Eye Questionnaire 5, underwent tear film evaluation, and had serum androgen levels measured. The correlations between androgen levels, DES composite scores, DES symptoms, and global, lipid, and aqueous tear film parameters were evaluated. Two hundred sixty-three patients with a mean age of 69 (50-95) were examined. There was no linear association between composite DES scores (generated using latent class analysis) and androgen levels. However, eyes with high DES scores (0.95-1.0) had higher levels of sex hormone-binding globulin (P = 0.03) and lower levels of dehydroepiandrosterone sulfate (DHEAS) (P = 0.02), androstenedione (A) (P = 0.02), and androstane-3α,17β-diol glucuronide (P = 0.03) compared to eyes with intermediate (0.05-0.95) or low (0-0.05) scores. There were no strong correlations between tear film measures and androgen levels. Regarding global parameters, a weak inverse correlation was found between corneal staining and A (r = -0.17, P = 0.009). For lipid parameters, a weak correlation existed between tear breakup time (TBUT) and A (r = 0.15, P = 0.02). When considering aqueous and lipid deficiency independently, the association between TBUT and A existed only with aqueous tear deficiency (r = 0.66, P = 0.002). Regarding aqueous parameters, a weak correlation existed between Schirmer test and DHEAS (r = 0.13, P = 0.047) and A (r = 0.21, P = 0.001). There was a weak correlation between higher levels of androstenedione and healthier global, lipid, and aqueous tear film parameters. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
Wang, Y; Ogawa, Y; Dogru, M; Kawai, M; Tatematsu, Y; Uchino, M; Okada, N; Igarashi, A; Kujira, A; Fujishima, H; Okamoto, S; Shimazaki, J; Tsubota, K
2008-02-01
We investigated the effect of 0.05% topical cyclosporine (Cys) on the ocular surface and tear functions in dry eye patients with chronic GVHD (cGVHD) in a prospective comparative study. Thirty eyes of 15 patients refractory to baseline treatment were recruited and the patients assigned for topical Cys treatment group (14 eyes of 7 patients) and control group (12 eyes of 6 patients) respectively. Two patients dropped out because of intolerable irritation while using topical Cys eye drops. Visual analog scale symptom scores, corneal sensitivity, Schirmer I test value, tear film break-up time (TBUT), tear evaporation rate and ocular surface vital staining scores were recorded at baseline and at the end of the following one month. Conjunctival impression and brush cytology were performed before and after the treatment. After topical Cys treatment, significant improvements were found in symptom scores, corneal sensitivity, tear evaporation rate, TBUT, vital staining scores, goblet cells density, conjunctival squamous metaplasia grade, inflammatory cell numbers and the MUC5AC expression. Our study suggests that 0.05% topical Cys may be an effective treatment for dry eye patients with cGVHD. The improvements in the ocular surface and tear functions resulted presumably from the decreased inflammation, increased goblet cell density and MUC5AC mRNA expression. Bone Marrow Transplantation (2008) 41, 293-302; doi:10.1038/sj.bmt.1705900; published online 5 November 2007.
Evaluation of outgassing, tear strength, and detail reproduction in alginate substitute materials.
Baxter, R T; Lawson, N C; Cakir, D; Beck, P; Ramp, L C; Burgess, J O
2012-01-01
To compare three alginate substitute materials to an alginate impression material for cast surface porosity (outgassing), tear strength, and detail reproduction. Detail reproduction tests were performed following American National Standards Institute/American Dental Association (ANSI/ADA) Specification No. 19. To measure tear strength, 12 samples of each material were made using a split mold, placed in a water bath until testing, and loaded in tension until failure at a rate of 500 mm/min using a universal testing machine. For cast surface porosity testing, five impressions of a Teflon mold with each material were placed in a water bath (37.8°C) for the in-mouth setting time and poured with vacuum-mixed Silky Rock die stone at 5, 10, 30, and 60 minutes from the start of mixing. The gypsum samples were analyzed with a digital microscope for surface porosity indicative of hydrogen gas release by comparing the surface obtained at each interval with four casts representing no, little, some, and significant porosity. Data analysis was performed using parametric and Kruskal-Wallis analysis of variance (ANOVA), Tukey/Kramer post-hoc tests (α=0.05), and individual Mann-Whitney U tests (α=0.0167). All alginate substitute materials passed the detail reproduction test. Tear strength of the alginate substitute materials was significantly better than alginate and formed three statistically different groups: AlgiNot had the lowest tear strength, Algin-X Ultra had the highest tear strength, and Position Penta Quick had intermediate tear strength. Significant variation in outgassing existed between materials and pouring times (p<0.05). All alginate substitute materials exhibited the least outgassing and cast porosity 60 minutes after mixing. Detail reproduction and tear strength of alginate substitute materials were superior to traditional alginate. The outgassing effect was minimal for most materials tested. Alginate substitute materials are superior replacements for irreversible hydrocolloid.
Evans, David J.; Fleiszig, Suzanne M. J.
2017-01-01
It is generally thought that mucosal fluids protect underlying epithelial surfaces against opportunistic infection via their antimicrobial activity. However, our published data show that human tear fluid can protect against the major opportunistic pathogen Pseudomonas aeruginosa independently of bacteriostatic activity. Here, we explored the mechanisms for tear protection, focusing on impacts of tear fluid on bacterial virulence factor expression. Results showed that tear fluid suppressed twitching motility, a type of surface-associated movement conferred by pili. Previously, we showed that twitching is critical for P. aeruginosa traversal of corneal epithelia, exit from epithelial cells after internalization, and corneal virulence. Inhibition of twitching by tear fluid was dose-dependent with dilutions to 6.25% retaining activity. Purified lactoferrin, lysozyme, and contrived tears containing these, and many other, tear components lacked the activity. Systematic protein fractionation, mass spectrometry, and immunoprecipitation identified the glycoprotein DMBT1 (Deleted in Malignant Brain Tumors 1) in tear fluid as required. DMBT1 purified from human saliva also inhibited twitching, as well as P. aeruginosa traversal of human corneal epithelial cells in vitro, and reduced disease pathology in a murine model of corneal infection. DMBT1 did not affect PilA expression, nor bacterial intracellular cyclicAMP levels, and suppressed twitching motility of P. aeruginosa chemotaxis mutants (chpB, pilK), and an adenylate cyclase mutant (cyaB). However, dot-immunoblot assays showed purified DMBT1 binding of pili extracted from PAO1 suggesting that twitching inhibition may involve a direct interaction with pili. The latter could affect extension or retraction of pili, their interactions with biotic or abiotic surfaces, or cause their aggregation. Together, the data suggest that DMBT1 inhibition of twitching motility contributes to the mechanisms by which mucosal fluids protect against P. aeruginosa infection. This study also advances our understanding of how mucosal fluids protect against infection, and suggests directions for novel biocompatible strategies to protect our surface epithelia against a major opportunistic pathogen. PMID:28489917
Neurturin-deficient mice develop dry eye and keratoconjunctivitis sicca.
Song, Xiu Jun; Li, De-Quan; Farley, William; Luo, Li Hui; Heuckeroth, Robert O; Milbrandt, Jeffrey; Pflugfelder, Stephen C
2003-10-01
Neurturin has been identified as a neurotrophic factor for parasympathetic neurons. Neurturin-deficient (NRTN(-/-)) mice have defective parasympathetic innervation of their lacrimal glands. This study was conducted to evaluate tear function and ocular surface phenotype in NRTN(-/-) mice. Determined by tail genomic DNA PCR, 25 NRTN(-/-) mice and 17 neurturin-normal (NRTN(+/+)) mice aged 6 weeks to 4 months were evaluated. Aqueous tear production, tear fluorescein clearance and corneal sensation were serially measured. Corneal permeability to AlexaFluor dextran (AFD; Molecular Probes, Eugene, OR) was measured by a fluorometric assay at 485 nm excitation and 530 nm emission. Histology was evaluated in PAS-stained sections. Mucin and HLA class II (IA) antigen were assessed by immunofluorescent staining. Tear IL-1beta was measured by ELISA, and tear matrix metalloproteinase (MMP)-9 by zymography. Gene expression in the corneal epithelia was analyzed by semiquantitative RT-PCR. In comparison to that in age-matched NRTN(+/+) mice, aqueous tear production, tear fluorescein clearance, and corneal sensation were significantly reduced in NRTN(-/-) mice, whereas corneal permeability to AFD was significantly increased. Immunoreactive MUC-4 and -5AC mucin and goblet cell density (P < 0.001) in the conjunctiva of NRTN(-/-) mice were lower than in NRTN(+/+) mice. The expression of MUC-1 and -4 mRNA by the corneal epithelium was reduced in NRTN(-/-) mice. There were a significantly greater number of IA antigen-positive conjunctival epithelial cells in NRTN(-/-) mice than NRTN(+/+) mice. Tear fluid IL-1beta and MMP-9 concentrations and the expression of IL-1beta, TNF-alpha, macrophage inflammatory protein (MIP)-2, cytokine-induced neutrophil chemoattractant (KC), and MMP-9 mRNA by the corneal epithelia were significantly increased in NRTN(-/-) mice, compared with NRTN(+/+) mice. Neurturin-deficient mice show phenotypic changes and ocular surface inflammation that mimic human keratoconjunctivitis sicca. This model supports the importance of a functional ocular surface-central nervous system-lacrimal gland sensory-autonomic neural network in maintaining ocular surface health and homeostasis.
Tear exchange and contact lenses: A review
Muntz, Alex; Subbaraman, Lakshman N.; Sorbara, Luigina; Jones, Lyndon
2015-01-01
Tear exchange beneath a contact lens facilitates ongoing fluid replenishment between the ocular surface and the lens. This exchange is considerably lower during the wear of soft lenses compared with rigid lenses. As a result, the accumulation of tear film debris and metabolic by-products between the cornea and a soft contact lens increases, potentially leading to complications. Lens design innovations have been proposed, but no substantial improvement in soft lens tear exchange has been reported. Researchers have determined post-lens tear exchange using several methods, notably fluorophotometry. However, due to technological limitations, little remains known about tear hydrodynamics around the lens and, to-date, true tear exchange with contact lenses has not been shown. Further knowledge regarding tear exchange could be vital in aiding better contact lens design, with the prospect of alleviating certain adverse ocular responses. This article reviews the literature to-date on the significance, implications and measurement of tear exchange with contact lenses. PMID:25575892
Tear Film Steroid Profiling in Dry Eye Disease by Liquid Chromatography Tandem Mass Spectrometry
Agnifili, Luca; Cicalini, Ilaria; Calienno, Roberta; Zucchelli, Mirco; Mastropasqua, Leonardo; Sacchetta, Paolo; Del Boccio, Piero; Rossi, Claudia
2017-01-01
Dry eye disease (DED) is a multifactorial disorder of the ocular surface unit resulting in eye discomfort, visual disturbance, and ocular surface damage; the risk of DED increases with age in both sexes, while its incidence is higher among females caused by an overall hormonal imbalance. The role of androgens has recently investigated and these hormones were considered to have a protective function on the ocular surface. In order to correlate DED to tear steroid levels, a robust, specific, and selective method for the simultaneous quantification of cortisol (CORT), corticosterone (CCONE), 11-deoxycortisol (11-DECOL), 4-androstene-3,17-dione (ADIONE), testosterone (TESTO), 17α-hydroxyprogesterone (17-OHP), and progesterone (PROG) was developed and applied for the analysis of tear samples. The method involves a simple extraction procedure of steroids from tears collected on Schirmer strips, followed by a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) analysis. In total, tear samples from 14 DED female patients and 13 healthy female controls were analysed and, CORT, ADIONE, and 17-OHP response levels resulted significantly decreased in dry eye patients respect to controls. The receiver operating characteristic (ROC) curve obtained by the combination of these three steroids (AUC = 0.964) demonstrated the good diagnostic power of the differential tear steroids in identifying DED. In conclusion, the present method made it possible, for the first time, to study steroid profiling directly in tear fluid. PMID:28672794
Multivariate Analyses of Rotator Cuff Pathologies in Shoulder Disability
Henseler, Jan F.; Raz, Yotam; Nagels, Jochem; van Zwet, Erik W.; Raz, Vered; Nelissen, Rob G. H. H.
2015-01-01
Background Disability of the shoulder joint is often caused by a tear in the rotator cuff (RC) muscles. Four RC muscles coordinate shoulder movement and stability, among them the supraspinatus and infraspinatus muscle which are predominantly torn. The contribution of each RC muscle to tear pathology is not fully understood. We hypothesized that muscle atrophy and fatty infiltration, features of RC muscle degeneration, are predictive of superior humeral head translation and shoulder functional disability. Methods Shoulder features, including RC muscle surface area and fatty infiltration, superior humeral translation and RC tear size were obtained from a consecutive series of Magnetic Resonance Imaging with arthrography (MRA). We investigated patients with superior (supraspinatus, n = 39) and posterosuperior (supraspinatus and infraspinatus, n = 30) RC tears, and patients with an intact RC (n = 52) as controls. The individual or combinatorial contribution of RC measures to superior humeral translation, as a sign of RC dysfunction, was investigated with univariate or multivariate models, respectively. Results Using the univariate model the infraspinatus surface area and fatty infiltration in both the supraspinatus and infraspinatus had a significant contribution to RC dysfunction. With the multivariate model, however, the infraspinatus surface area only affected superior humeral translation (p<0.001) and discriminated between superior and posterosuperior tears. In contrast neither tear size nor fatty infiltration of the supraspinatus or infraspinatus contributed to superior humeral translation. Conclusion Our study reveals that infraspinatus atrophy has the strongest contribution to RC tear pathologies. This suggests a pivotal role for the infraspinatus in preventing shoulder disability. PMID:25710703
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hayasaki, K.; Sohn, B.W.; Jung, T.
2015-07-01
We study the warping and tearing of a geometrically thin, non-self-gravitating disk surrounding binary supermassive black holes on an eccentric orbit. The circumbinary disk is significantly misaligned with the binary orbital plane, and is subject to the time-dependent tidal torques. In principle, such a disk is warped and precesses, and is torn into mutually misaligned rings in the region, where the tidal precession torques are stronger than the local viscous torques. We derive the tidal-warp and tearing radii of the misaligned circumbinary disks around eccentric SMBH binaries. We find that in disks with the viscosity parameter α larger than amore » critical value depending on the disk aspect ratio, the disk warping appears outside the tearing radius. This condition is expressed for small amplitude warps as α > √H/(3r) for H/r∼<0.1, where H is the disk scale height. If α < √H/(3r), only the disk tearing occurs because the tidal warp radius is inside the tearing radius, where most of disk material is likely to rapidly accrete onto SMBHs. In warped and torn disks, both the tidal-warp and the tearing radii most strongly depend on the binary semi-major axis, although they also mildly depend on the other orbital and disk parameters. This strong dependence enables us to estimate the semi-major axis, once the tidal warp or tearing radius is determined observationally: for the tidal warp radius of 0.1 pc, the semi-major axis is estimated to be ∼10{sup −2} pc for 10{sup 7} M{sub ⊙} black hole with typical orbital and disk parameters. We also briefly discuss the possibility that central objects of observed warped maser disks in active galactic nuclei are supermassive black hole binaries.« less
Lee, Kwan Bok; Koh, Kyung Min; Kwon, Young A; Song, Sang Wroul; Kim, Byoung Yeop; Chung, Jae Lim
2017-08-01
To evaluate changes in the tear meniscus area and tear meniscus height over time in patients with dry eye syndrome, using anterior segment spectral-domain optical coherence tomography after the instillation of 3% diquafosol ophthalmic solution. Sixty eyes from 30 patients with mild to moderate dry eye syndrome were included. Tear meniscus images acquired by anterior segment spectral-domain optical coherence tomography were analyzed using National Institutes of Health's image-analysis software (ImageJ 1.44p). Tear meniscus area and tear meniscus height were measured at baseline, 5 minutes, 10 minutes, and 30 minutes after instillation of a drop of diquafosol in one eye and normal saline in the other eye. Changes in ocular surface disease index score, tear film break-up time, corneal staining score by Oxford schema, and meibomian expressibility were also evaluated at baseline, and after 1 week and 1 month of a diquafosol daily regimen. Sixty eyes from 30 subjects (mean age, 29.3 years; 8 men and 22 women) were included. In eyes receiving diquafosol, tear volume was increased at 5 and 10 minutes compared with baseline. It was also higher than saline instilled eyes at 5, 10, and 30 minutes. Changes in tear volume with respect to baseline were not statistically different after the use of diquafosol for 1 month. Ocular surface disease index score, tear film break-up time, and Oxford cornea stain score were significantly improved after 1 week and 1 month of daily diquafosol instillation, but meibomian expressibility did not change. Topical diquafosol ophthalmic solution effectively increased tear volume for up to 30 minutes, compared to normal saline in patients with dry eye syndrome. © 2017 The Korean Ophthalmological Society
Surface folding in metals: a mechanism for delamination wear in sliding
Mahato, Anirban; Guo, Yang; Sundaram, Narayan K.; Chandrasekar, Srinivasan
2014-01-01
Using high-resolution, in situ imaging of a hard, wedge-shaped model asperity sliding against a metal surface, we demonstrate a new mechanism for particle formation and delamination wear. Damage to the residual surface is caused by the occurrence of folds on the free surface of the prow-shaped region ahead of the wedge. This damage manifests itself as shallow crack-like features and surface tears, which are inclined at very acute angles to the surface. The transformation of folds into cracks, tears and particles is directly captured. Notably, a single sliding pass is sufficient to damage the surface, and subsequent passes result in the generation of platelet-like wear particles. Tracking the folding process at every stage from surface bumps to folds to cracks/tears/particles ensures that there is no ambiguity in capturing the mechanism of wear. Because fold formation and consequent delamination are quite general, our findings have broad applicability beyond wear itself, including implications for design of surface generation and conditioning processes. PMID:25197251
Calvão-Santos, Gil; Borges, Cristina; Nunes, Sandrina; Salgado-Borges, José; Duarte, Lilianne
2011-01-01
To compare the efficacy of 3 different artificial tears (AT) acting primarily in one of the 3 tear film layers (Tears Again®, lipidic; Opticol®, aqueous; Optive®, mucin) in recovering the tear film changes in patients with dry eye symptoms due to external causes. A total of 27 patients, with dry eye symptoms associated with extra hours of computer or contact lenses use, were randomized to 4 treatment groups: A received Tears Again®; B received Optive®; C received Opticol®; D received no treatment (control). Patients were observed in 3 visits: day 0, day 7, and day 30. Tear break-up time (TBUT) and Schirmer tests and the Ocular Surface Disease Index were performed. Data analysis was performed. There were no significant differences between the groups. From day 0 to day 30, there was a decrease in the number of eyes with abnormal TBUT (not significant) and Schirmer (significant in A, B, D; p<0.031). There was an increase in the average TBUT for all groups (significant in A, C; p<0.001) and a decrease in the average Schirmer value in groups B, C, and D (not significant) and an increase in group A (p = 0.002). There was a decrease in the average Ocular Surface Disease Index value in all groups (p<0.045). All AT were efficient at recovering the tear film, but those acting primarily on the internal and intermediate layer led to a mild decline on lachrymal production. An association of different kinds of AT acting on each layer can be the best treatment for corneal surface diseases affecting eye lubrication.
Nankivil, Derek; Gonzalez, Alex; Arrieta, Esdras; Rowaan, Cornelis; Aguilar, Mariela C; Sotolongo, Krystal; Cabot, Florence A; Yoo, Sonia H; Parel, Jean-Marie A
2014-06-19
To develop a safe, noninvasive, noncontact, continuous in vivo method to measure the dehydration rate of the precorneal tear film and to compare the effectiveness of a viscoelastic agent in maintaining the precorneal tear film to that of a balanced salt solution. Software was designed to analyze the corneal reflection produced by the operating microscope's coaxial illumination. The software characterized the shape of the reflection, which became distorted as the precorneal tear film evaporated; characterization was accomplished by fitting an ellipse to the reflection and measuring its projected surface area. Balanced salt solution Plus (BSS+) and a 2% hydroxypropylmethylcellulose viscoelastic were used as the test agents. The tear film evaporation rate was characterized and compared over a period of 20 minutes in 20 eyes from 10 New Zealand white rabbits. The ellipse axes ratio and surface area were found to decrease initially after each application of either viscoelastic or BSS+ and then to increase linearly as the tear film began to evaporate (P < 0.001) for eyes treated with BSS+ only. Eyes treated with BSS+ required 7.5 ± 2.7 applications to maintain sufficient corneal hydration during the 20-minute test period, whereas eyes treated with viscoelastic required 1.4 ± 0.5 applications. The rates of evaporation differed significantly (P < 0.043) between viscoelastic and BSS+. The shape and surface area of the corneal reflection are strongly correlated with the state of the tear film. Rabbits' corneas treated with viscoelastic remained hydrated significantly longer than corneas treated with BSS+. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
Assay of mucins in human tear fluid.
Spurr-Michaud, Sandra; Argüeso, Pablo; Gipson, Ilene
2007-05-01
Mucin genes, both secreted (MUC2, MUC5AC, MUC5B, MUC7) and membrane associated (MUC1, MUC4, MUC16), have been reported to be expressed by ocular surface epithelia. The purpose of this study was to comprehensively assay the mucin content of human tear fluid using multiple antibodies for each mucin and to develop a sensitive, semi-quantitative method for the assay of mucins in tears. Tear washes were obtained by instillation of saline onto the ocular surface, followed by collection from the inferior fornix. Tear proteins were separated in 1% agarose gels, transferred to nitrocellulose membrane by vacuum blotting and probed with multiple antibodies recognizing MUC1, MUC2, MUC4, MUC5AC, MUC5B, MUC7 and MUC16. Binding was detected using chemiluminescence, and quantity was determined by densitometry. Serial dilutions of pooled tears from normal individuals were assayed to determine the linear range of detectability. MUC1, MUC4, MUC16, MUC5AC and low levels of MUC2 were consistently detected in human tear fluid, while MUC5B and MUC7 were not. Use of several antibodies recognizing different epitopes on the same mucin confirmed these findings. The antibodies to mucins bound to serial dilutions of tears in a linear fashion (r2 > 0.9), indicating the feasibility of semi-quantitation. MUC5AC in tear fluid had an increased electrophoretic mobility compared to MUC5AC isolated from conjunctival tissue. This study provides clear evidence that the mucin component of tears is a mixture of secreted and shed membrane-associated mucins, and for the first time demonstrates MUC16 in tear fluid. Immunoblots of tears using agarose gel electrophoresis and chemiluminescence detection provide a semi-quantitative assay for mucin protein that will be useful for comparisons with tears from diseased eyes or after pharmacological intervention.
Assay of Mucins in Human Tear Fluid
Spurr-Michaud, Sandra; Argüeso, Pablo; Gipson, Ilene
2007-01-01
Mucin genes, both secreted (MUC2, MUC5AC, MUC5B, MUC7) and membrane associated (MUC1, MUC4, MUC16), have been reported to be expressed by ocular surface epithelia. The purpose of this study was to comprehensively assay the mucin content of human tear fluid using multiple antibodies for each mucin and to develop a sensitive, semi-quantitative method for the assay of mucins in tears. Tear washes were obtained by instillation of saline onto the ocular surface, followed by collection from the inferior fornix. Tear proteins were separated in 1% agarose gels, transferred to nitrocellulose membrane by vacuum blotting and probed with multiple antibodies recognizing MUC1, MUC2, MUC4, MUC5AC, MUC5B, MUC7 and MUC16. Binding was detected using chemiluminescence, and quantity was determined by densitometry. Serial dilutions of pooled tears from normal individuals were assayed to determine the linear range of detectability. MUC1, MUC4, MUC16, MUC5AC and low levels of MUC2 were consistently detected in human tear fluid, while MUC5B and MUC7 were not. Use of several antibodies recognizing different epitopes on the same mucin confirmed these findings. The antibodies to mucins bound to serial dilutions of tears in a linear fashion (r2 >0.9), indicating the feasibility of semi-quantitation. MUC5AC in tear fluid had an increased electrophoretic mobility compared to MUC5AC isolated from conjunctival tissue. This study provides clear evidence that the mucin component of tears is a mixture of secreted and shed membrane-associated mucins, and for the first time demonstrates MUC16 in tear fluid. Immunoblots of tears using agarose gel electrophoresis and chemiluminescence detection provide a semi-quantitative assay for mucin protein that will be useful for comparisons with tears from diseased eyes or after pharmacological intervention. PMID:17399701
Ocular surface disease incidence in patients with open-angle glaucoma.
Radenković, Marija; Stanković-Babić, Gordana; Jovanović, Predrag; Djordjević-Jocić, Jasmina; Trenkić-Božinović, Marija
2016-01-01
Ocular surface disease (OSD) is a multifactorial disease of the tears and ocular surface that results in symptoms of discomfort, visual disturbances, tear film instability with potential damage to the ocular surface, accompanied by increased tear film osmolarity and inflammation of the ocular surface. It is a consequence of disrupted homeostasis of lacrimal functional unit. The main pathogenetic mechanism stems from tear hyperosmolarity and tear film instability. The etiological classification is hyposecretory (Sy-Sjögren and non-Sjögren) and evaporative (extrinsic and intrinsic) form. Delphi panel classification grades disease stages. Antiglaucoma topical therapy causes exacerbation or occurrence of symptoms of dry eye due to main ingredients or preservatives (benzalkonium chloride – BAK), which are dose- and time-dependent. BAK reduces the stability of the lipid layer of tears, the number of goblet cells, induces apoptosis and inflammatory infiltration. The aim of this study was the analysis of the OSD incidence in open-angle glaucoma patients caused by topical medicamentous therapy. Retrospective analysis of examined patients with open-angle glaucoma was used. Increased incidence of moderate and advanced OSD Index degrees in the group of primary open-angle glaucoma (POAG) and pseudoexfoliative glaucoma. According to the Delphi Panel Scale the most common grade is IIb (POAG and pseudoexfoliative glaucoma). Evaporative form of OSD prevailed in all treatment groups. High percentage of dry eye in patients with higher concentrations of preservatives applied was noticed. OSD should be timely diagnosed and treated. Dry eye has an impact on surgical outcome and postoperative visual acuity, and in order to improve patient compliance and quality of life, symptoms of dry eye should be addressed and medications with lower concentrations of preservatives should be applied.
Yang, Chih-Huang; Albietz, Julie; Harkin, Damien G; Kimlin, Michael G; Schmid, Katrina L
2018-02-01
To determine the possible association between serum vitamin D levels and dry eye symptoms, and the impact of an oral vitamin D supplement. Three linked studies were performed. (i) 29 older adult participants, (ii) 29 dry eyed participants, and (iii) 2-month vitamin D supplementation for 32 dry eyed/low serum vitamin D levelled participants. All participants were assessed by the Ocular Surface Diseases Index (OSDI) to determine dry eye symptoms, and the phenol red thread test (PRT) and/or Schirmer's tear test, tear meniscus height, non-invasive tear break up time, grading ocular surface redness and fluorescein staining of the cornea to detect the tear quality and ocular surface conditions. Blood samples were collected for serum vitamin D analysis and interleukin-6 (IL-6) levels. Among older adult participants, vitamin D levels were negatively correlated with dry eye symptoms, the severity of dry eye, and associated with tired eye symptom. Vitamin D levels of people with dry eye diagnosis were not correlated with OSDI scores and IL-6 levels; while IL-6 levels showed correlation with tear production. In supplement study, vitamin D levels increased by 29mol/l, while dry eye symptoms and grading of corneal staining appeared significant reductions. No significant changes in IL-6 levels. Low vitamin D levels (<50nmol/l) were associated with dry eye symptoms in older individuals but not those diagnosed with dry eye. Vitamin D supplement increased the vitamin D levels, and improved dry eye symptoms, the tear quality and ocular surface conditions. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Evaporation and Hydrocarbon Chain Conformation of Surface Lipid Films.
Sledge, Samiyyah M; Khimji, Hussain; Borchman, Douglas; Oliver, Alexandria L; Michael, Heidi; Dennis, Emily K; Gerlach, Dylan; Bhola, Rahul; Stephen, Elsa
2016-10-01
The inhibition of the rate of evaporation (R evap ) by surface lipids is relevant to reservoirs and dry eye. Our aim was to test the idea that lipid surface films inhibit R evap . R evap were determined gravimetrically. Hydrocarbon chain conformation and structure were measured using a Raman microscope. Six 1-hydroxyl hydrocarbons (11-24 carbons in length) and human meibum were studied. Reflex tears were obtained from a 62-year-old male. The Raman scattering intensity of the lipid film deviated by about 7 % for hydroxyl lipids and varied by 21 % for meibum films across the entire film at a resolution of 5 μm 2 . All of the surface lipids were ordered. R evap of the shorter chain hydroxyl lipids were slightly (7%) but significantly lower compared with the longer chain hydroxyl lipids. R evap of both groups was essentially similar to that of buffer. A hydroxyl lipid film did not influence R evap over an estimated average thickness range of 0.69 to >6.9 μm. R evap of human tears and buffer with and without human meibum (34.4 μm thick) was not significantly different. R evap of human tears was not significantly different from buffer. Human meibum and hydroxyl lipids, regardless of their fluidity, chain length, or thickness did not inhibit R evap of buffer or tears even though they completely covered the surface. It is unlikely that hydroxyl lipids can be used to inhibit R evap of reservoirs. Our data do not support the widely accepted (yet unconfirmed) idea that the tear film lipid layer inhibits R evap of tears. Copyright © 2016 Elsevier Inc. All rights reserved.
Case control study of dry eye and related ocular surface abnormalities in Ibadan, Nigeria.
Bekibele, C O; Baiyeroju, A M; Ajaiyeoba, A; Akang, E E U; Ajayi, B G K
2010-02-01
Tear instability is associated with symptoms of ocular discomfort and irritation. Many patients with dry eyes remain untreated due to improper diagnoses. To identify symptoms and surface abnormalities associated with dry eyes. One hundred and fifty-six eyes of 78 subjects attending the Eye Clinic of the University College Hospital Ibadan were screened for dry eyes/tear instability using rose Bengal stain (graded 0-9), tear break-up time (TBUT), Schirmer's 1 tests, tear meniscus height and a standardised symptoms questionnaire. Grades 4-9 rose Bengal staining were considered as positive dry eye and were compared with grades 0-3 staining eyes as negative controls. Mean tear meniscus height, Schirmer's test and TBUT were lower among cases than their corresponding control eyes. The difference between the mean Schirmer's test values of cases and their controls were statistically significant (P = 0.00 for right eyes and P = 0.002 for left eyes). Rose Bengal grades were inversely correlated with the mean Schirmer's values (Pearson correlation -0.429, P = 0.05 for right eyes and -0.335, P = 0.03 for left eyes) and TBUT (Pearson correlation -0.316, P = 0.05 for right eyes and -0.212, P = 0.06 for left eyes). About 95.8% of the cases were symptomatic, as opposed to 70.4% of the controls (P = 0.01, Fisher's exact test) and 95.8% of dry right eyes compared to 61.1% of their controls had ocular surface abnormalities (P = 0.001), while 89.5% of dry left eyes compared to 62.7% of controls had surface abnormalities (P = 0.07). A close relationship exists between ocular irritation symptoms, surface abnormalities and functional evidence of tear instability. Such patients should be treated empirically or screened for dry eyes.
Influence of Ophthalmic Solutions on Tear Components.
Shigeyasu, Chika; Yamada, Masakazu; Akune, Yoko
2016-11-01
Tear fluids are a mixture of secretions derived from lacrimal glands, accessory lacrimal glands, conjunctiva, and meibomian glands. Compositional changes to tears occur in the normal state and during ocular surface disease, such as dry eye conditions. We have investigated compositional changes to tears after topical application of ophthalmic solutions, with regard to tear-specific proteins (secretory immunoglobulin A, lactoferrin, lipocalin-1, and lysozyme) and ocular surface mucin in normal and dry eye conditions using high-performance liquid chromatography. After application of saline solution (0.9% sodium chloride) in normal subjects, transient but significant decreases in all tear components were observed. The recovery of protein concentrations took up to 30 minutes and lasted longer when the saline solution was applied more frequently. When applying ophthalmic solutions, a balance between washout and dilutional effects should be considered in addition to the therapeutic effect. Investigation of the effect of diquafosol solution (3%) in normal subjects revealed a significant increase in sialic acid concentration, a marker of ocular mucin, at 5 minutes after application, whereas a significant decrease was observed with saline. This result indicates the accelerated secretion of mucin from ocular tissues induced by diquafosol. A clinical study to determine the efficacy of diquafosol in patients with dry eye revealed improvements in tear breakup time, keratoconjunctival staining scores, and Schirmer test score, accompanied by an increase in sialic acid concentration in tears. Investigating normal and dry eye conditions through tear analysis may clarify the pathophysiology of dry eye conditions and support the efficacy of treatments.
Coupled Kelvin-Helmholtz and Tearing Mode Instabilities at the Mercury's Magnetopause
NASA Astrophysics Data System (ADS)
Ivanovski, S. L.; Milillo, A.; Kartalev, M.; Massetti, S.
2018-05-01
A MHD approach for numerical simulations of coupled Kelvin-Helmholtz and tearing mode instabilities has been applied to Mercury’s magnetopause and used to perform a physical parameters study constrained by the MESSENGER data.
Ji, Yong Woo; Lee, Jeihoon; Lee, Hun; Seo, Kyoung Yul; Kim, Eung Kweon; Kim, Tae-Im
2017-02-01
To investigate automated values from an advanced corneal topographer with a built-in real keratometer, color camera, and ocular surface interferometer for the evaluation of non-Sjögren dry eye syndrome (NSDES) with meibomian gland dysfunction (MGD). Sixty-four patients (64 eyes) diagnosed with NSDES with MGD were enrolled. All eyes were evaluated using the Ocular Surface Disease Index (OSDI), fluorescence staining score, tear film breakup time (TBUT), Schirmer test, and MGD grade. Noninvasive Keratograph average tear film breakup time (NIKBUTav), tear meniscus height (TMHk), meibomian gland (MG) dropout grade, and lipid layer thickness (LLT) using interferometry were measured. Among automated indexes, NIKBUTav (mean 7.68 ± 4.07 s) and the MG dropout grade (mean 1.0 ± 0.5) significantly correlated with the OSDI (mean 40.6 ± 22.9) (r = -0.337, P = 0.006; and r = 0.201, P = 0.023, respectively), as did all conventional indicators, except the Schirmer score (mean 9.1 ± 5.9 mm). TMHk (mean 0.21 ± 0.18 mm) had significant correlation with the Schirmer score, the staining score (mean 1.2 ± 0.7), TBUT (mean 3.8 ± 1.8 s), and NIKBUTav (r = 0.298, P = 0.007; r = -0.268, P = 0.016; r = 0.459, P < 0.001; and r = 0.439, P < 0.001, respectively), but not any MGD indicator, even the MG dropout grade. NIKBUTav showed significant correlations with all clinical parameters and other automated values, except the Schirmer score and LLT (mean 83.94 ± 20.82 nm) (all (Equation is included in full-text article.)≥ 0.25 and P < 0.01). The MG dropout grade highly correlated with all indexes except TMHk (all (Equation is included in full-text article.)≥ 0.25 and P < 0.05). LLT was significantly associated with TBUT, MGD grade (mean 2.0 ± 0.7), and MG dropout grade (r = 0.219, P = 0.047; r = -0.221, P = 0.039; and r = 0.433, P < 0.001, respectively), although it was not related to patient symptoms. Automated noninvasive measurements using an advanced corneal topographer and LLT measured with an ocular surface interferometer can be alternatives to conventional methods to evaluate tear conditions on the ocular surface; the former device can provide information about conformational MG changes in NSDES with MGD.
The knee: Surface-coil MR imaging at 1. 5 T
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beltran, J.; Noto, A.M.; Mosure, J.C.
1986-06-01
Seven normal knees (in five volunteers) and seven injured knees (in seven patients) were examined by high-resolution magnetic resonance (MR) imaging at 1.5 T with a surface coil. Seven medial meniscal tears, three anterior cruciate ligament tears, one posterior cruciate ligament avulsion, an old osteochondral fracture, femoral condylar chondro-malacia, and one case of semimembranous tendon reinsertion were identified. MR images correlated well with recent double-contrast arthrograms or results of surgery. All tears were identified in both the sagittal and coronal planes. Because of its ability to demonstrate small meniscal lesions and ligamentous injuries readily, MR imaging with a surface coilmore » may eventually replace the more invasive arthrography.« less
Tearing modes induced by perpendicular electron cyclotron resonance heating in the KSTAR tokamak
NASA Astrophysics Data System (ADS)
Lee, H. H.; Lee, S. G.; Seol, J.; Aydemir, A. Y.; Bae, C.; Yoo, J. W.; Na, Y. S.; Kim, H. S.; Woo, M. H.; Kim, J.; Joung, M.; You, K. I.; Park, B. H.
2014-10-01
This paper reports on experimental evidence that shows perpendicular electron cyclotron resonance heating (ECRH) can trigger classical tearing modes when deposited near a rational flux surface. The complex evolution of an m = 2 island is followed during current ramp-up in KSTAR plasmas, from its initial onset as the rational surface enters the ECRH resonance layer to its eventual lock on the wall after the rational surface leaves the layer. Stability analysis coupled to a transport calculation of the current profile with ECRH shows that the perpendicular ECRH may play a significant role in triggering and destabilizing classical m = 2 tearing modes, in agreement with our experimental observation.
The role of the lacrimal functional unit in the pathophysiology of dry eye.
Stern, Michael E; Gao, Jianping; Siemasko, Karyn F; Beuerman, Roger W; Pflugfelder, Stephen C
2004-03-01
The majority of dry eye symptoms are due to a chronic inflammation of the lacrimal functional unit resulting in a loss of tear film integrity and normal function. This leads to a reduction in the ability of the ocular surface to respond to environmental challenges. The underlying cause of tear film dysfunction is the alteration of tear aqueous, mucin, and lipid components. This may result from a systemic autoimmune disease or a local autoimmune event. A lack of systemic androgen support to the lacrimal gland has been shown to be a facilitative factor in the initiation of this type of pathophysiology. Tear secretion is controlled by the lacrimal functional unit consisting of the ocular surface (cornea, conjunctiva, accessory lacrimal glands, and meibomian glands), the main lacrimal gland and the interconnecting innervation. If any portion of this functional unit is compromised, lacrimal gland support to the ocular surface is impeded. Factors such as neurogenic inflammation and T cell involvement in the disease pathogenesis as well as newly developed animal models of ocular surface inflammation are discussed.
Noninvasive Dry Eye Assessment Using High-Technology Ophthalmic Examination Devices.
Yamaguchi, Masahiko; Sakane, Yuri; Kamao, Tomoyuki; Zheng, Xiaodong; Goto, Tomoko; Shiraishi, Atsushi; Ohashi, Yuichi
2016-11-01
Recently, the number of dry eye cases has dramatically increased. Thus, it is important that easy screening, exact diagnoses, and suitable treatments be available. We developed 3 original and noninvasive assessments for this disorder. First, a DR-1 dry eye monitor was used to determine the tear meniscus height quantitatively by capturing a tear meniscus digital image that was analyzed by Meniscus Processor software. The DR-1 meniscus height value significantly correlated with the fluorescein meniscus height (r = 0.06, Bland-Altman analysis). At a cutoff value of 0.22 mm, sensitivity of the dry eye diagnosis was 84.1% with 90.9% specificity. Second, the Tear Stability Analysis System was used to quantitatively measure tear film stability using a topographic modeling system corneal shape analysis device. Tear film stability was objectively and quantitatively evaluated every second during sustained eye openings. The Tear Stability Analysis System is currently installed in an RT-7000 autorefractometer and topographer to automate the diagnosis of dry eye. Third, the Ocular Surface Thermographer uses ophthalmic thermography for diagnosis. The decrease in ocular surface temperature in dry eyes was significantly greater than that in normal eyes (P < 0.001) at 10 seconds after eye opening. Decreased corneal temperature correlated significantly with the tear film breakup time (r = 0.572; P < 0.001). When changes in the ocular surface temperature of the cornea were used as indicators for dry eye, sensitivity was 0.83 and specificity was 0.80 after 10 seconds. This article describes the details and potential of these 3 noninvasive dry eye assessment systems.
Wakamatsu, Tais Hitomi; Okada, Naoko; Kojima, Takashi; Matsumoto, Yukihiro; Ibrahim, Osama M.A.; Adan, Enrique Sato; Fukagawa, Kazumi; Katakami, Chikako; Tsubota, Kazuo; Shimazaki, Jun; Fujishima, Hiroshi
2009-01-01
Purpose To elucidate the status of the conjunctival inflammation in atopic keratoconjunctivitis (AKC) using laser scanning confocal microscopy and compare the relevant findings with conjunctival brush cytology in a prospective controlled study. Methods Twenty eyes from 20 AKC patients as well as 16 eyes from 16 age and sex matched normal subjects were studied. The subjects underwent tear film break-up time (BUT), fluorescein and Rose Bengal staining of the ocular surface, conjunctival confocal microscopy, Schirmer test, and brush cytology. Brush cytology specimens and in vivo confocal microscopy scans underwent evaluation for inflammatory cell densities. Results Brush cytology specimens and in vivo confocal microscopy scans from AKC patients revealed significantly higher numbers of inflammatory cells (p<0.05). Conjunctival inflammatory cell density showed a negative correlation with tear stability and a positive correlation with vital staining scores and conjunctival injection grades. The extent of conjunctival inflammation assessed by in vivo confocal microscopy showed a strong positive linear correlation with the inflammation status evaluated by brush cytology. The corneal inflammatory cell density assessed by in vivo confocal microscopy showed a significant negative correlation with tear stability and a positive linear correlation with corneal fluorescein staining. Conclusions Confocal scanning laser microscopy is an efficient, noninvasive, and a promising tool for the quantitative assessment of conjunctival inflammation, a parameter of this new technology which correlated well with subjective and objective ocular surface clinical findings. PMID:19693288
Assessing tear film on soft contact lenses with lateral shearing interferometry.
Szczesna, Dorota H
2011-11-01
Evaluating precorneal tear film is one of important clinical measurements for assessing health of anterior eye. Contact lens wear is known to influence the quality of tear film. The aim was to evaluate the applicability of lateral shearing interferometry technique in the noninvasive assessment of the effects of contact lens replacement modality and its water content on tear film stability. Sixteen regular soft contact lens wearers took place in the study. Lateral shearing interferometry measurements, in suppressed blinking conditions, were taken in the mornings and afternoons, after a minimum of 5 hours of lens wear for the daily lenses, and after 2 weeks and 1 month for the fortnightly and monthly lens replacement modalities, respectively. Significant differences (paired bootstrap-based Behrens-Fisher test, P < 0.05) in the tear film surface quality were found between all considered pairs of replacement modalities except for the daily and fortnightly lenses measured in the afternoon of the first day of wear. Significant worsening (paired bootstrap-based Behrens-Fisher test, P < 0.001) of tear film quality was found for the low water content materials. Lateral shearing interferometry is a powerful method for the noninvasive assessment of tear film surface quality on soft contact lenses that may find, in future, its use in the clinical assessment of anterior eye's health.
Pseudomonas aeruginosa Survival at Posterior Contact Lens Surfaces after Daily Wear
Wu, Yvonne T.; Zhu, Lucia S.; Tam, K. P. Connie; Evans, David J.; Fleiszig, Suzanne M. J.
2015-01-01
Purpose Pseudomonas aeruginosa keratitis is a sight-threatening complication of contact lens wear, yet mechanisms by which lenses predispose to infection remain unclear. Here, we tested the hypothesis that tear fluid at the posterior contact lens surface can lose antimicrobial activity over time during lens wear. Methods Daily disposable lenses were worn for 1, 2, 4, 6 or 8 h immediately after removal from their packaging, or after presoaking in sterile saline for 2 days to remove packaging solution. Unworn lenses were also tested, some coated in tears “aged” in vitro for 1 or 8 h. Lenses were placed anterior surface down into tryptic soy agar cradles containing gentamicin (100µg/ml) to kill bacteria already on the lens, and posterior surfaces inoculated with gentamicin-resistant P. aeruginosa for 3 h. Surviving bacteria were enumerated by viable counts of lens homogenates. Results Posterior surfaces of lenses worn by patients for 8 h supported more P. aeruginosa growth than lenses worn for only 1 h, if lenses were presoaked prior to wear (~ 2.4-fold, p = 0.01). This increase was offset if lenses were not presoaked to remove packaging solution (p = 0.04 at 2 h and 4 h). Irrespective of presoaking, lenses worn for 8 h showed more growth on their posterior surface than unworn lenses coated with tear fluid that was “aged” for 8 h vitro (~8.6-fold, presoaked, p = 0.003: ~ 5.4-fold from packaging solution, p = 0.004). Indeed, in vitro incubation did not impact tear antimicrobial activity. Conclusions This study shows that post lens tear fluid can lose antimicrobial activity over time during contact lens wear, supporting the idea that efficient tear exchange under a lens is critical for homeostasis. Additional studies are needed to determine applicability to other lens types, wearing modalities, and relevance to contact lens-related infections. PMID:25955639
Tauste, Ana; Ronda, Elena; Baste, Valborg; Bråtveit, Magne; Moen, Bente E; Seguí Crespo, María-Del-Mar
2018-04-01
To analyze differences in the ocular surface appearance and tear film status of contact lens wearers and non-wearers in a group of visual display terminals (VDT) workers and additionally to assess differences between lens materials. Cross-sectional study of 236 office workers, of whom 92 were contact lens wearers. Workers provided information on their contact lenses (conventional hydrogel, silicone hydrogel or rigid gas permeable lenses) and exposure to VDT at work. Ocular surface and tear film status were determined by the presence of bulbar, limbal and lid redness, lid roughness and corneal staining type, and by Schirmer's and tear break-up time tests (TBUT). A generalized linear model was used to calculate the crude (cRR) and age- and sex-adjusted (aRR) relative risk to measure the association between ocular surface and tear film abnormalities and contact lens use and type. The aRR of ocular surface abnormalities was higher in contact lens wearers compared to non-wearers: bulbar redness (aRR 1.69; 95% CI 1.25-2.30), limbal redness (aRR 2.87; 1.88-4.37), lid redness (aRR 2.53; 1.35-4.73) and lid roughness (aRR 7.03; 1.31-37.82). VDT exposure > 4 h/day increased wearers' risk of limbal and lid redness. Conventional hydrogel wearers had the highest risk of ocular surface abnormalities, followed by silicone hydrogel wearers. Both contact and non-contact lens wearers had a high prevalence of altered TBUT (77.3 and 75.7% respectively) and Schirmer (51.8 and 41.3%). Regular contact lens use during VDT exposure at work increases risk of bulbar, limbal and lid redness, and lid roughness, especially in soft contact lens wearers. The high prevalence of altered TBUT and Schirmer's results in all participants suggests that VDT use greatly affects tear film characteristics.
NASA Astrophysics Data System (ADS)
Wang, Xiaojing; Yu, Qingquan; Zhang, Xiaodong; Zhang, Yang; Zhu, Sizheng; Wang, Xiaoguang; Wu, Bin
2018-04-01
Numerical studies on the stabilization of neoclassical tearing modes (NTMs) by electron cyclotron current drive (ECCD) have been carried out based on reduced MHD equations, focusing on the amount of the required driven current for mode stabilization and the comparison with analytical results. The dependence of the minimum driven current required for NTM stabilization on some parameters, including the bootstrap current density, radial width of the driven current, radial deviation of the driven current from the resonant surface, and the island width when applying ECCD, are studied. By fitting the numerical results, simple expressions for these dependences are obtained. Analysis based on the modified Rutherford equation (MRE) has also been carried out, and the corresponding results have the same trend as numerical ones, while a quantitative difference between them exists. This difference becomes smaller when the applied radio frequency (rf) current is smaller.
Tetteh, Sophia; Bibb, Richard J; Martin, Simon J
2018-05-30
The objective of this study was to determine the effect of plant based antimicrobial solutions specifically tea tree and Manuka oil on facial silicone elastomers. The purpose of this in vitro study was to evaluate the effect of disinfection with plant extract solution on mechanical properties and morphology on the silicone elastomer. Test specimens were subjected to disinfection using tea tree oil, Manuka oil and the staphylococcus epidermidis bacteria. Furthermore, a procedure duration was used in the disinfection process to simulate up to one year of usage. Over 500 test specimens were fabricated for all tests performed namely hardness, elongation, tensile, tear strength tests, visual inspection and lastly surface characterization using SEM. A repeated measures ANOVA revealed that hardness and elongation at break varied significantly over the time period, whereas this was not observed in the tear and tensile strength parameters of the test samples.
Tear exchange and contact lenses: a review.
Muntz, Alex; Subbaraman, Lakshman N; Sorbara, Luigina; Jones, Lyndon
2015-01-01
Tear exchange beneath a contact lens facilitates ongoing fluid replenishment between the ocular surface and the lens. This exchange is considerably lower during the wear of soft lenses compared with rigid lenses. As a result, the accumulation of tear film debris and metabolic by-products between the cornea and a soft contact lens increases, potentially leading to complications. Lens design innovations have been proposed, but no substantial improvement in soft lens tear exchange has been reported. Researchers have determined post-lens tear exchange using several methods, notably fluorophotometry. However, due to technological limitations, little remains known about tear hydrodynamics around the lens and, to-date, true tear exchange with contact lenses has not been shown. Further knowledge regarding tear exchange could be vital in aiding better contact lens design, with the prospect of alleviating certain adverse ocular responses. This article reviews the literature to-date on the significance, implications and measurement of tear exchange with contact lenses. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.
Electronic enhancement of tear secretion
NASA Astrophysics Data System (ADS)
Brinton, Mark; Lim Chung, Jae; Kossler, Andrea; Kook, Koung Hoon; Loudin, Jim; Franke, Manfred; Palanker, Daniel
2016-02-01
Objective. To study electrical stimulation of the lacrimal gland and afferent nerves for enhanced tear secretion, as a potential treatment for dry eye disease. We investigate the response pathways and electrical parameters to safely maximize tear secretion. Approach. We evaluated the tear response to electrical stimulation of the lacrimal gland and afferent nerves in isofluorane-anesthetized rabbits. In acute studies, electrical stimulation was performed using bipolar platinum foil electrodes, implanted beneath the inferior lacrimal gland, and a monopolar electrode placed near the afferent ethmoid nerve. Wireless microstimulators with bipolar electrodes were implanted beneath the lacrimal gland for chronic studies. To identify the response pathways, we applied various pharmacological inhibitors. To optimize the stimulus, we measured tear secretion rate (Schirmer test) as a function of pulse amplitude (1.5-12 mA), duration (0.1-1 ms) and repetition rate (10-100 Hz). Main results. Stimulation of the lacrimal gland increased tear secretion by engaging efferent parasympathetic nerves. Tearing increased with stimulation amplitude, pulse duration and repetition rate, up to 70 Hz. Stimulation with 3 mA, 500 μs pulses at 70 Hz provided a 4.5 mm (125%) increase in Schirmer score. Modulating duty cycle further increased tearing up to 57%, compared to continuous stimulation in chronically implanted animals (36%). Ethmoid (afferent) nerve stimulation increased tearing similar to gland stimulation (3.6 mm) via a reflex pathway. In animals with chronically implanted stimulators, a nearly 6 mm increase (57%) was achieved with 12-fold less charge density per pulse (0.06-0.3 μC mm-2 with 170-680 μs pulses) than the damage threshold (3.5 μC mm-2 with 1 ms pulses). Significance. Electrical stimulation of the lacrimal gland or afferent nerves may be used as a treatment for dry eye disease. Clinical trials should validate this approach in patients with aqueous tear deficiency, and further optimize electrical parameters for maximum clinical efficacy.
Jirsova, Katerina; Brejchova, Kristyna; Krabcova, Ivana; Filipec, Martin; Al Fakih, Aref; Palos, Michalis; Vesela, Viera
2014-01-01
To assess the impact of autologous serum (AS) eye drops on the ocular surface of patients with bilateral severe dry eye and to draw a comparison between the clinical and laboratory examinations and the degree of subjective symptoms before and after serum treatment. A three-month prospective study was conducted on 17 patients with severe dry eye. AS eye drops were applied a maximum of 12 times a day together with regular therapy. Dry eye status was evaluated by clinical examination (visual acuity, Schirmer test, tear film breakup time, vital staining, tear film debris and meniscus), conjunctival impression cytology (epithelial and goblet cell density, snake-like chromatin, HLA-DR-positive and apoptotic cells) and subjectively by the patients. The application of AS eye drops led to a significant improvement in the Schirmer test (p < 0.01) and tear film debris (p < 0.05). The densities of goblet (p < 0.0001) and epithelial cells (p < 0.05) were significantly increased, indicating a decrease of squamous metaplasia after AS treatment. A significant decrease (p < 0.05) was found in the number of apoptotic, HLA-DR-positive and snake-like chromatin cells on the ocular surface. A significant improvement was found in all evaluated subjective symptoms. Altogether, the clinical results were improved in 77%, the laboratory results in 75% and the subjective feelings in 63% of the eyes. We found that three-month AS treatment led especially to the improvement of ocular surface dryness and damage of the epithelium. The improvement of dry eye after AS treatment correlated well with the clinical, laboratory and subjective findings. From the patients' subjective point of view, the positive effect of AS decreased with time, but still persisted up to three months after the end of therapy.
Behavior of sphingomyelin and ceramide in a tear film lipid layer model.
Olżyńska, Agnieszka; Cwiklik, Lukasz
2017-03-01
Tear film lipid layer is a complex lipid mixture forming the outermost interface between eye and environment. Its key characteristics, such as surface tension and structural stability, are governed by the presence of polar lipids. The origin of these lipids and exact composition of the mixture are still elusive. We focus on two minor polar lipid components of the tear film lipid later: sphingomyelin and ceramide. By employing coarse grain molecular dynamics in silico simulations accompanied by Langmuir balance experiments we provide molecular-level insight into behavior of these two lipids in a tear film lipid layer model. Sphingomyelin headgroups are significantly exposed at the water-lipids boundary while ceramide molecules are incorporated between other lipids frequently interacting with nonpolar lipids. Even though these two lipids increase surface tension of the film, their molecular-level behavior suggests that they have a stabilizing effect on the tear film lipid layer. Copyright © 2016 Elsevier GmbH. All rights reserved.
Stern, Michael E; Pflugfelder, Stephen C
2004-04-01
Dry eye is a condition of altered tear composition that results from a diseased or dysfunctional lacrimal functional unit. Evidence suggests that inflammation causes structural alterations and/or functional paralysis of the tear-secreting glands. Changes in tear composition resulting from lacrimal dysfunction, increased evaporation and/or poor clearance have pro-inflammatory effects on the ocular surface. This inflammation is responsible in part for the irritation symptoms, ocular surface epithelial disease, and altered corneal epithelial barrier function in dry eye. Anti-inflammatory therapies for dry eye target one or more of the inflammatory mediators/pathways that have been identified in dry eye.
Interactions of toroidally coupled tearing modes in the KSTAR tokamak
NASA Astrophysics Data System (ADS)
Kim, Gnan; Yun, Gunsu S.; Woo, Minho; Park, Hyeon K.; KSTAR Team2, the
2018-03-01
The evolutions of toroidally coupled radially-distant and radially-adjacent tearing modes are visualized in 2D in detail on the Korea superconducting tokamak for advanced research. The coupled tearing modes are in-phase on the out-board mid-plane and become destabilized or compete with each other depending on their spatial separation. When two coupled tearing modes are far apart, both are increasingly destabilized. On the other hand, when they become close to each other, one becomes stabilized while the other becomes destabilized. In such cases, an additional tearing mode is often formed on outer rational flux surface and the three tearing modes compete. The competitions suggest that spatial overlap (merging) of coupled magnetic islands is difficult.
A MODEL FOR THE TEAR FILM AND OCULAR SURFACE TEMPERATURE FOR PARTIAL BLINKS
Deng, Quan; Braun, R. J.; Driscoll, T. A.; King-Smith, P. E.
2015-01-01
In this paper, we investigate the dynamics of tear film and the associated temperature variation for partial blinks. We investigate the mechanism of fluid supply during partial blink cycles, and compare the film thickness with observation in vivo. We find that varying the thickness of the fluid layer beneath the moving upper lid improves the agreement for the in vivo measurement of tear film thickness after a half blink. By examining the flux of the fluid, we provide an explanation of this assumption. We also investigate the temperature dynamics both at the ocular surface and inside the simulated anterior chamber. Our simulation results suggest that the ocular surface temperature readjusts rapidly to normal temperature distribution after partial blinks. PMID:25635242
Tear dysfunction and the cornea: LXVIII Edward Jackson Memorial Lecture.
Pflugfelder, Stephen C
2011-12-01
To describe the cause and consequence of tear dysfunction-related corneal disease. Perspective on effects of tear dysfunction on the cornea. Evidence is presented on the effects of tear dysfunction on corneal morphology, function, and health, as well as efficacy of therapies for tear dysfunction-related corneal disease. Tear dysfunction is a prevalent eye disease and the most frequent cause for superficial corneal epithelial disease that results in corneal barrier disruption, an irregular optical surface, light scattering, optical aberrations, and exposure and sensitization of pain-sensing nerve endings (nociceptors). Tear dysfunction-related corneal disease causes irritation and visual symptoms such as photophobia and blurred and fluctuating vision that may decrease quality of life. Dysfunction of 1 or more components of the lacrimal functional unit results in changes in tear composition, including elevated osmolarity and increased concentrations of matrix metalloproteinases, inflammatory cytokines, and chemokines. These tear compositional changes promote disruption of tight junctions, alter differentiation, and accelerate death of corneal epithelial cells. Corneal epithelial disease resulting from tear dysfunction causes eye irritation and decreases visual function. Clinical and basic research has improved understanding of the pathogenesis of tear dysfunction-related corneal epithelial disease, as well as treatment outcomes. Copyright © 2011 Elsevier Inc. All rights reserved.
Increased Tear Film Osmolarity in Systemic Lupus Erythematosus.
Duru, Necati; Altinkaynak, Hasan; Uysal, Betul Seher; Duru, Zeynep; Can, Mehmet Erol; Erten, Sukran; Yuksel, Nilay; Kalkan Akcay, Emine
2017-01-01
To evaluate tear film osmolarity in patients with systemic lupus erythematosus (SLE). A total of 55 eyes from 55 patients with SLE and 47 eyes from 47 age- and gender-matched healthy individuals were included in this study. Tear film osmolarity was evaluated with a lab-on-a-chip technique (TearLab; TearLab Corporation, San Diego, CA) in SLE patients in comparison with healthy individuals, and results were correlated to clinically available diagnostic tests for dry eye, such as tear film break-up time (BUT), Schirmer's test, and Ocular Surface Disease Index (OSDI). The mean tear film osmolarity in the SLE patients and healthy individuals was 306.02 ± 13.27 mOsm/L and 300.74 ± 9.11 mOsm/L, respectively, which made for a statistically significant difference (p = 0.020). In the SLE group, tear film osmolarity was negatively correlated with the Schirmer's test score and the BUT value (r = -0.295 p = 0.029 and r = 0.347 p = 0.009, respectively), whereas tear film osmolarity was not correlated with OSDI score (r = -0.182 p = 0.183). This study revealed that tear film hyperosmolarity and abnormal tear film function are associated with SLE.
The Effect of Ambient Ozone on Unsaturated Tear Film Wax Esters.
Paananen, Riku O; Rantamäki, Antti H; Parshintsev, Jevgeni; Holopainen, Juha M
2015-12-01
Tear film lipid layer (TFLL) is constantly exposed to reactive ozone in the surrounding air, which may have detrimental effects on ocular health. Behenyl oleate (BO), a representative tear film wax ester, was used to study the reaction with ozone at the air-water interface. Time-dependent changes in mean molecular area of BO monolayers were measured at different ozone concentrations and surface pressures. In addition, the effect of ascorbic acid on the reaction rate was determined. Reaction was followed using thin-layer chromatography and reaction products were identified using liquid chromatography-electrospray ionization mass spectrometry (LC-MS). Tear fluid samples from healthy subjects were analyzed with LC-MS for any ozonolysis reaction products. Behenyl oleate was found to undergo rapid ozonolysis at the air-water interface at normal indoor ozone concentrations. The reaction was observed as an initial expansion followed by a contraction of the film area. Ascorbic acid was found to decrease the rate of ozonolysis. Main reaction products were identified as behenyl 9-oxononanoate and behenyl 8-(5-octyl-1,2,4-trioxolan-3-yl)octanoate. Similar ozonolysis products were not detected in the tear fluid samples. At the air-water interface, unsaturated wax esters react readily with ozone in ambient air. However, no signs of ozonolysis products were found in the tear fluid. This is most likely due to the antioxidant systems present in tear fluid. Last, the results show that ozonolysis needs to be controlled in future surface chemistry studies on tear film lipids.
NASA Astrophysics Data System (ADS)
Yokoyama, Moe; Yamada, Kenji; Nishimura, Takahiro; Kido, Michiko; Jeong, Hieyong; Ohno, Yuko
2015-03-01
Therapeutic drug monitoring (TDM) contributes to safe and effective pharmacotherapy in clinical fields. A simple, rapid, low-cost, and minimally-invasive drug measurement method attracts much interest for point-of-care TDM. Tear fluids can be collected minimally-invasively compared to blood sampling and there is a correlation between a drug concentration in tears and that in bloods. Surface enhanced Raman spectroscopy (SERS) with paper-based substrate is useful for point-of-care TDM owing to inexpensiveness and high-sensitivity. Paper is also a safe tear collection tool. Then we are studying on a paper-based SERS of tear specimen for point-of-care TDM. In this paper, to improve sensitivity in measuring drug concentration in tear fluids, we fabricated a SERS substrate by coating gold nano-rods on a paper substrate and evaluated whether the fabricated substrate can enhance Raman scattering. Sodium phenobarbital (PB), an anti-convulsant agent, was used as a target. In experiment, the fabricated substrate indicated the lower detection limit of PB in a solution than a plain paper substrate. This result showed the potential of the paper based SERS substrate to measure drug concentration in tears simply and inexpensively.
Goldmann Tonometer Prism with an Optimized Error Correcting Applanation Surface.
McCafferty, Sean; Lim, Garrett; Duncan, William; Enikov, Eniko; Schwiegerling, Jim
2016-09-01
We evaluate solutions for an applanating surface modification to the Goldmann tonometer prism, which substantially negates the errors due to patient variability in biomechanics. A modified Goldmann or correcting applanation tonometry surface (CATS) prism is presented which was optimized to minimize the intraocular pressure (IOP) error due to corneal thickness, stiffness, curvature, and tear film. Mathematical modeling with finite element analysis (FEA) and manometric IOP referenced cadaver eyes were used to optimize and validate the design. Mathematical modeling of the optimized CATS prism indicates an approximate 50% reduction in each of the corneal biomechanical and tear film errors. Manometric IOP referenced pressure in cadaveric eyes demonstrates substantial equivalence to GAT in nominal eyes with the CATS prism as predicted by modeling theory. A CATS modified Goldmann prism is theoretically able to significantly improve the accuracy of IOP measurement without changing Goldmann measurement technique or interpretation. Clinical validation is needed but the analysis indicates a reduction in CCT error alone to less than ±2 mm Hg using the CATS prism in 100% of a standard population compared to only 54% less than ±2 mm Hg error with the present Goldmann prism. This article presents an easily adopted novel approach and critical design parameters to improve the accuracy of a Goldmann applanating tonometer.
Patel, Roshni; Zhu, Meifang; Robertson, Danielle M
2018-06-01
The human corneal epithelium expresses both the insulin-like growth factor type 1 receptor (IGF-1R) and the IGF-1R/insulin receptor (INSR) hybrid. Despite the previous identification of IGF-1 in human tear fluid, little is known regarding the regulation of IGF-1 in tear fluid and its role in corneal epithelial homeostasis. In the present study, we investigated the impact of biological parameters on the concentration of human tear levels of IGF-1. Tear levels of IGF-1 were measured in 41 healthy, human volunteers without any reported symptoms of dry eye. All volunteers underwent standard biomicroscopic examination of the cornea and tear film. In a subgroup of volunteers, corneal staining with sodium fluorescein, tear film break up time and tear production using a Schirmer's test strip were measured to assess clinical signs of dry eye. Tears were collected from the inferior tear meniscus using glass microcapillary tubes and IGF-1 levels were measured using a solid phase sandwich ELISA. Tear levels of IGF-1 were highest in young adults and significantly decreased in older adults (P = 0.003). There were no differences in tear IGF-1 between males and females (P = 0.628). Tear IGF-1 levels were correlated with tear film break up time (R = 0.738) and tear production (R = 0.826). These data indicate that there is a progressive decline in tear IGF-1 due to aging that is associated with clinical signs of dry eye. This effect is likely due to age-related changes in the lacrimal gland. Copyright © 2018 Elsevier Ltd. All rights reserved.
Effect of contact lens wear and a near task on tear film break-up.
Jansen, Meredith E; Begley, Carolyn G; Himebaugh, Nikole H; Port, Nicholas L
2010-05-01
To study the effect of extrinsic controls on blinking by examining blink parameters and tear stability among adapted soft contact lens (CL) wearers performing tasks that require varying amounts of visual concentration. The Demographic Questionnaire, Contact Lens Dry Eye Questionnaire, and Current Symptoms Questionnaire were completed by 15 adapted soft CL wearers (nine females). Three 55 s simultaneous measurements of tear film stability via retroillumination and blinking were obtained with a slit-lamp biomicroscope and 200 Hz video camera while subjects listened to music and played a video game with and without their habitual CLs. Interblink interval (IBI) and blink amplitude (BA) were calculated. The area of break-up (AB) was calculated for the retroillumination image before each blink. The Current Symptoms Questionnaire was completed four times throughout testing. With the game compared to music, IBI was significantly longer and BA significantly decreased without CLs (p < or = 0.001). With CLs, the IBI did not significantly change between tasks but the BA significantly decreased (p = 0.100). The AB significantly increased with CL and the game (paired t-test, p < or = 0.001). The BA was significantly correlated with self-reported severity of dry eye for all testing scenarios (Spearman r > or = 0.5579, p < 0.0001) and several symptom measures (Spearman r > or = 0.6262, p < 0.0001). The AB was significantly correlated with symptom measures including bothersome discomfort for the game with and without CLs (Spearman r > or = 0.5064, p < 0.0001). During tasks requiring concentration, the IBI increased (blink rate decreased) and many blinks were incomplete without CLs. With CLs, tear film instability increased. Blinking frequency also increased, but it remained high when subjects played the game, and symptoms of ocular irritation increased. This suggests that wearing soft CLs, even when fully adapted, provides enough extrinsic ocular surface stimulation to override internal controls and affect blink parameters.
Detection of sialomucin complex (MUC4) in human ocular surface epithelium and tear fluid.
Pflugfelder, S C; Liu, Z; Monroy, D; Li, D Q; Carvajal, M E; Price-Schiavi, S A; Idris, N; Solomon, A; Perez, A; Carraway, K L
2000-05-01
To evaluate human ocular surface epithelium and tear fluid for the presence of sialomucin complex (MUC4), a high-molecular-weight heterodimeric glycoprotein composed of mucin (ASGP-1) and transmembrane (ASGP-2) subunits. Reverse transcription-polymerase chain reaction (RT-PCR) and Northern blot analysis assays were used to identify sialomucin complex RNA in ocular surface epithelia. Immunoprecipitation and immunoblot analysis were used to identify immunoreactive species in human tears and in the corneal and conjunctival epithelia using antibodies specific for carbohydrate and peptide epitopes on the sialomucin complex subunits. Immunofluorescence staining was used to detect sialomucin complex in frozen sections and impression cytology specimens of human cornea and conjunctival epithelia. ASGP-1- and ASGP-2-specific sequences were amplified from RNA extracted from both conjunctival and corneal epithelial biopsies by RT-PCR. Sialomucin complex transcripts were also detected in these tissues by Northern blot analysis, with a greater level of RNA detected in the peripheral than the central corneal epithelium. Sialomucin complex was immunoprecipitated from tear fluid samples and both corneal and conjunctival epithelia and detected by immunoblot analysis with specific anti-ASGP-1 and anti-ASGP-2 antibodies. The ASGP-1 peptide antibody HA-1 stained the full thickness of the corneal and conjunctival epithelia. In contrast, antibody 15H10, which reacts against a carbohydrate epitope on ASGP-1, stained only the superficial epithelial layers of these tissues. No staining was observed in the conjunctival goblet cells. Sialomucin complex was originally identified in rat mammary adenocarcinoma cells and has recently been shown to be produced by the ocular surface epithelia of rats. Furthermore, it has been identified as the rat homologue of human MUC4 mucin. The present studies show that it is expressed in the stratified epithelium covering the surface of the human eye and is present in human tear fluid. Expression of a carbohydrate-dependent epitope on the mucin subunit (ASGP-1) of sialomucin complex occurs in a differentiation-dependent fashion. Sialomucin complex joins MUC1 as another membrane mucin produced by the human ocular surface epithelia but is also found in the tear fluid, presumably in a soluble form, as found on the rat ocular surface.
Özyol, Pelin; Özyol, Erhan; Karalezli, Aylin
2018-01-01
To examine the effect of a single dose of artificial tear administration on automated visual field (VF) testing in patients with glaucoma and dry eye syndrome. A total of 35 patients with primary open-angle glaucoma experienced in VF testing with symptoms of dry eye were enrolled in this study. At the first visit, standard VF testing was performed. At the second and third visits with an interval of one week, while the left eyes served as control, one drop of artificial tear was administered to each patient's right eye, and then VF testing was performed again. The reliability parameters, VF indices, number of depressed points at probability levels of pattern deviation plots, and test times were compared between visits. No significant difference was observed in any VF testing parameters of control eyes (P>0.05). In artificial tear administered eyes, significant improvement was observed in test duration, mean deviation, and the number of depressed points at probability levels (P˂0.5%, P˂1%, P˂2) of pattern deviation plots (P˂0.05). The post-hoc test revealed that artificial tear administration elicited an improvement in test duration, mean deviation, and the number of depressed points at probability levels (P˂0.5%, P˂1%, P˂2%) of pattern deviation plots from first visit to second and third visits (P˂0.01, for all comparisons). The intraclass correlation coefficient for the three VF test indices was found to be between 0.735 and 0.85 (P<0.001, for all). A single dose of artificial tear administration immediately before VF testing seems to improve test results and decrease test time.
[Novel current and future therapy options for treatment of dry eye disease].
Messmer, E M
2018-02-01
Dry eye disease was redefined by the dry eye workshop (DEWS II) in May 2017. According to the new definition "dry eye is a multifactorial disease of the ocular surface characterized by a loss of homeostasis of the tear film and accompanied by ocular symptoms". The current definition encompasses etiological factors, such as instability and hyperosmolarity of the tear film, ocular surface inflammation and damage as well as a new aspect compared to the former definition, neurosensory abnormalities. Recent and future therapeutic options for dry eye focus on treatment of the aforementioned pathogenetic events. New tear substitutes, medications and devices to stimulate tear production, innovative anti-inflammatory treatment, medications to influence corneal innervation and new methods for treatment of Meibomian gland dysfunction are already available or will be available in the near future.
Association of IL-21 cytokine with severity of primary Sjögren syndrome dry eye.
Lim, Sung A; Nam, Doo Hyun; Lee, Jee Hye; Kwok, Seung-Ki; Park, Sung-Hwan; Chung, So-Hyang
2015-03-01
IL-21 plays an important role in primary Sjögren syndrome (SS) pathogenesis. The purpose of this study was to evaluate IL-21 expression in tears and the conjunctiva and to analyze the impact of IL-21 on primary SS dry eyes. Eighty subjects were enrolled in this study: 30 patients with primary SS dry eye (30 eyes); 30 patients with non-SS dry eye (30 eyes), and 20 normal controls. Tear IL-21 levels were measured by flow cytometry, and IL-21 gene expression in the conjunctiva from impression cytology was evaluated by quantitative polymerase chain reaction. Ocular Surface Disease Index, tear film breakup time, Schirmer I test, and ocular surface staining scores were obtained for all patients. Primary SS dry eyes had significantly higher tear IL-21 levels than non-SS dry eyes and normal controls (P < 0.01). In addition, IL-21 gene expression in the conjunctiva was also higher in primary SS dry eyes than in non-SS dry eyes and normal controls (P < 0.01). However, there were no significant differences in IL-21 expression in tears and the conjunctiva between non-SS dry eyes and controls. The tear IL-21 level was significantly correlated with ocular surface stain scores (r = 0.54, P < 0.01) and Schirmer I test values (r = -0.23, P < 0.05) in primary SS dry eyes. Our findings suggest that severity of primary SS dry eye is associated with IL-21.
Pieragostino, Damiana; Bucci, Sonia; Agnifili, Luca; Fasanella, Vincenzo; D'Aguanno, Simona; Mastropasqua, Alessandra; Ciancaglini, Marco; Mastropasqua, Leonardo; Di Ilio, Carmine; Sacchetta, Paolo; Urbani, Andrea; Del Boccio, Piero
2012-04-01
Primary open angle (POAG) and pseudoexfoliative glaucoma (PXG) are the most common primary and secondary forms of glaucoma, respectively. Even though the patho-physiology, aqueous humor composition, risk factors, clinical features, therapy and drug induced ocular surface changes in POAG and PXG have been widely studied, to date information concerning tear protein characterization is lacking. Tears are a source of nourishment for ocular surface tissues and a vehicle to remove local waste products, metabolized drugs and inflammatory mediators produced in several ophthalmic diseases. In glaucoma, the proteomic definition of tears may provide insights concerning patho-physiology of the disease and ocular surface modifications induced by topical therapy. Our study aimed at characterizing protein patterns in tears of patients with medically controlled POAG and PXG. A comparative tears proteomic analysis by label-free LC-MS(E) highlighted differences in the expression of several proteins in the two glaucoma sub-types and control subjects, highlighting inflammation pathways expressed in both diseases. Results were independently reconfirmed by SDS-PAGE and linear MALDI-TOF MS, validating altered levels of Lysozyme C, Lipocalin-1, Protein S100, Immunoglobulins and Prolactin Inducible Protein. Moreover, we found a differential pattern of phosphorylated Cystatin-S that distinguishes the two pathologies. The most relevant results suggest that in both pathologies there may be active inflammation pathways related to the disease and/or induced by therapy. We show, for the first time, tear protein patterns expressed under controlled intraocular pressure conditions in POAG and PXG subjects. These findings could help in the understanding of molecular machinery underlying these ophthalmologic diseases, resulting in early diagnosis and more specific therapy.
Lacritin and other new proteins of the lacrimal functional unit.
McKown, Robert L; Wang, Ningning; Raab, Ronald W; Karnati, Roy; Zhang, Yinghui; Williams, Patricia B; Laurie, Gordon W
2009-05-01
The lacrimal functional unit (LFU) is defined by the 2007 International Dry Eye WorkShop as 'an integrated system comprising the lacrimal glands, ocular surface (cornea, conjunctiva and meibomian glands) and lids, and the sensory and motor nerves that connect them'. The LFU maintains a healthy ocular surface primarily through a properly functioning tear film that provides protection, lubrication, and an environment for corneal epithelial cell renewal. LFU cells express thousands of proteins. Over 200 new LFU proteins have been discovered in the last decade. Lacritin is a new LFU-specific growth factor in human tears that flows through ducts to target corneal epithelial cells on the ocular surface. When applied topically in rabbits, lacritin appears to increase the volume of basal tear secretion. Lacritin is one of only a handful of tear proteins preliminarily reported to be downregulated in blepharitis and in two dry eye syndromes. Computational analysis predicts an ordered C-terminal domain that binds the corneal epithelial cell surface proteoglycan syndecan-1 (SDC1) and is required for lacritin's low nanomolar mitogenic activity. The lacritin-binding site on the N-terminus of SDC1 is exposed by heparanase. Heparanase is constitutively expressed by the corneal epithelium and appears to be a normal constituent of tears. Binding triggers rapid signaling to downstream NFAT and mTOR. A wealth of other new proteins, originally designated as hypothetical when first identified by genomic sequencing, are expressed by the human LFU including: ALS2CL, ARHGEF19, KIAA1109, PLXNA1, POLG, WIPI1 and ZMIZ2. Their demonstrated or implied roles in human genetic disease or basic cellular functions are fuel for new investigation. Addressing topical areas in ocular surface physiology with new LFU proteins may reveal interesting new biological mechanisms and help get to the heart of ocular surface dysfunction.
The effects of differential flow between rational surfaces on toroidal resistive MHD modes
NASA Astrophysics Data System (ADS)
Brennan, Dylan; Halfmoon, Michael; Rhodes, Dov; Cole, Andrew; Okabayashi, Michio; Paz-Soldan, Carlos; Finn, John
2016-10-01
Differential flow between resonant surfaces can strongly affect the coupling and penetration of resonant components of resistive modes, and yet this mechanism is not yet fully understood. This study focuses on the evolution of tearing instabilities and the penetration of imposed resonant magnetic perturbations (RMPs) in tokamak configurations relevant to DIII-D and ITER, including equilibrium flow shear. It has been observed on DIII-D that the onset of tearing instabilities leading to disruption is often coincident with a loss of differential rotation between a higher m/n tearing surface (normally the 4/3 or 3/2) and a lower m/n tearing surface (normally the 2/1). Imposing RMPs can strongly affect this coupling and the torques between the modes. We apply the nonlinear 3-D resistive magnetohydrodynamic (MHD) code NIMROD to study the mechanisms by which these couplings occur. Reduced MHD analyses are applied to study the effects of differential flow between resonant surfaces in the simulations. Interaction between resonant modes can cause significant energy transfer between them, effectively stabilizing one mode while the other grows. The flow mitigates this transfer, but also affects the individual modes. The combination of these effects determines the nonlinear outcome. Supported by US DOE Grants DE-SC0014005 and DE-SC0014119.
Diagnosis of dry eye disease and emerging technologies
Zeev, Maya Salomon-Ben; Miller, Darby Douglas; Latkany, Robert
2014-01-01
Dry eye is one of the most commonly encountered problems in ophthalmology. Signs can include punctate epithelial erosions, hyperemia, low tear lakes, rapid tear break-up time, and meibomian gland disease. Current methods of diagnosis include a slit-lamp examination with and without different stains, including fluorescein, rose bengal, and lissamine green. Other methods are the Schirmer test, tear function index, tear break-up time, and functional visual acuity. Emerging technologies include meniscometry, optical coherence tomography, tear film stability analysis, interferometry, tear osmolarity, the tear film normalization test, ocular surface thermography, and tear biomarkers. Patient-specific considerations involve relevant history of autoimmune disease, refractive surgery or use of oral medications, and allergies or rosacea. Other patient considerations include clinical examination for lid margin disease and presence of lagophthalmos or blink abnormalities. Given a complex presentation and a variety of signs and symptoms, it would be beneficial if there was an inexpensive, readily available, and reproducible diagnostic test for dry eye. PMID:24672224
On tear film breakup (TBU): dynamics and imaging.
Braun, Richard J; Driscoll, Tobin A; Begley, Carolyn G; King-Smith, P Ewen; Siddique, Javed I
2018-06-13
We report the results of some recent experiments to visualize tear film dynamics. We then study a mathematical model for tear film thinning and tear film breakup (TBU), a term from the ocular surface literature. The thinning is driven by an imposed tear film thinning rate which is input from in vivo measurements. Solutes representing osmolarity and fluorescein are included in the model. Osmolarity causes osmosis from the model ocular surface, and the fluorescein is used to compute the intensity corresponding closely to in vivo observations. The imposed thinning can be either one-dimensional or axisymmetric, leading to streaks or spots of TBU, respectively. For a spatially-uniform (flat) film, osmosis would cease thinning and balance mass lost due to evaporation; for these space-dependent evaporation profiles TBU does occur because osmolarity diffuses out of the TBU into the surrounding tear film, in agreement with previous results. The intensity pattern predicted based on the fluorescein concentration is compared with the computed thickness profiles; this comparison is important for interpreting in vivo observations. The non-dimensionalization introduced leads to insight about the relative importance of the competing processes; it leads to a classification of large vs small TBU regions in which different physical effects are dominant. Many regions of TBU may be considered small, revealing that the flow inside the film has an appreciable influence on fluorescence imaging of the tear film.
Concentrations of MUC16 and MUC5AC using three tear collection methods
Nichols, Jason J.
2017-01-01
Purpose To determine the optimal tear collection method for analysis of ocular surface mucins MUC5AC and MUC16. Methods Fifteen subjects without ocular surface disease were recruited. Subjects presented for tear collection on three separate days for three different tear collection methods with the order of method randomized. Methods used to collect tears from right and left eyes included Schirmer’s strip, basal tear collection, and flush tear collection. All samples from the right eyes were individually analyzed for MUC5AC whereas the left eye samples were individually analyzed for MUC16. For each individual sample, 10 μg of protein were loaded per lane into a 1% (w/v) agarose gel and run in electrophoresis buffer for 2 h. After overnight capillary transfer, membranes were incubated with either MUC5AC antibody CLH2 or MUC16 antibody OC125 for western blot analysis. Blots were developed with enhanced chemiluminescence (ECL) and signals captured with the Odyssey Fc (LI-COR). The relative amounts of MUC5AC and MUC16 were quantified with densitometry using software and compared for statistically significant differences between tear collection methods using the Kruskal–Wallis test in SPSS 22 and GraphPad Prism 7.02. Dunn’s multiple comparisons test was used for pairwise post-hoc comparisons. Results Samples containing less than 10 μg of total protein were not used for analysis which left eight samples (out of 45) unusable. The calculated MUC5AC median signal intensities from Schirmer’s strip, basal tears, and flush tears were 2.86 (n = 15, the interquartile range [IQR] = 2.54–3.21), 1.65 (n = 14, IQR = 1.34–3.1), and 1.67 (n = 9, IQR = 1.42–1.72), respectively (H = 9.5, p = 0.009). Post-hoc pairwise comparisons showed a statistically significant difference between Schirmer’s strip and flush tears (p = 0.01). The calculated MUC16 median signal intensities from Schirmer’s strip, basal tears, and flush tears were 1.88 (n = 14, IQR = 1.43–2.61), 5.24 (n = 15, IQR = 4.16–6.21), and 2.45 (n = 7, IQR = 1.85–2.48), respectively (H = 18.1, p = 0.001). Post-hoc pairwise comparison showed statistically significant differences between basal tears and Schirmer’s strip (p = 0.0003) and between basal tears and flush tears (p = 0.006). Conclusions MUC5AC and MUC16 are present in human tear fluid and can be captured using various tear collection methods. Although basal tear collection yielded the highest relative concentration of MUC16, Schirmer’s strip tear collection yielded the highest MUC5AC concentration. Therefore, the tear collection method chosen depends on the mucin of interest. PMID:28761326
Tear menisci after laser in situ keratomileusis with mechanical microkeratome and femtosecond laser.
Xie, Wenjia; Zhang, Dong; Chen, Jia; Liu, Jing; Yu, Ye; Hu, Liang
2014-08-21
To investigate the effect on tear menisci after laser in situ keratomileusis (LASIK) with flap creation by either microkeratome or femtosecond laser. Sixty eyes of 30 myopes were analyzed. Fifteen patients underwent LASIK with Moria II microkeratome, and the other 15 patients with 60-KHz IntraLase femtosecond laser. Upper and lower tear meniscus parameters of height (UTMH, LTMH) and area (UTMA, LTMA) were measured by SD-OCT preoperatively and 1 week, 1 month, and 3 months postoperatively. Compared with the baseline values, all tear meniscus parameters decreased significantly at each postoperative time point (all P < 0.01) in both groups. LTMH increased significantly between 1 week and 1 month and between 1 and 3 months after surgery in the microkeratome (both P < 0.01) and femtosecond laser groups (P < 0.01, P = 0.012, respectively). There were significant increases in LTMA between 1 week and 1 month after surgery in the microkeratome group (P < 0.01) and in the femtosecond laser group (P = 0.028). There were no significant differences in UTMH, UTMA, LTMH, or LTMA between two groups. The depth of ablation was negatively correlated with the LTMA at 1 week after surgery (R = -0.256, P = 0.049) for all patients. There were no significant differences in the tear meniscus parameters between the microkeratome and femtosecond laser groups. The depth of ablation was significantly correlated with the LTMA only at 1 week after surgery. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
Maharana, Prafulla K; Raghuwanshi, Sapna; Chauhan, Ashish K; Rai, Vaishali G; Pattebahadur, Rajesh
2017-01-01
To compare the efficacy of carboxymethylcellulose 0.5% (CMC), hydroxypropyl-guar containing polyethylene glycol 400/propylene glycol (PEG/PG), and hydroxypropyl methylcellulose 0.3% (HPMC) as tear substitutes in patients with dry eye. A retrospective evaluation of cases presenting with symptoms of dry eye from July 2014 to June 2015 was done. Patients with Ocular Surface Disease Index (OSDI) scoring >12 were included in the study. Parameters such as age, gender, Schirmer test (ST), and tear film breakup time (TBUT) were recorded on day 0, week 1, and week 4. For analysis, cases were divided into three groups; Group 1 - CMC, Group 2 - PEG/PG, and Group 3 - HPMC. Overall, 120 patients were included in the study. Demographic data and baseline characteristics were comparable among the groups. Group 2 had significant improvement in percentage change in OSDI (weeks 0-1, 0-4, and 1-4, P = 0.00), TBUT (weeks 0-1, P = 0.01; 0-4, P = 0.006; and 1-4, P = 0.007), and in ST (weeks 0-1, P = 0.02; 0-4, P = 0.002; and 1-4, P = 0.008) compared to Group 1 at all follow-ups. Group 3 had improvements similar to Group 2, but it was not at all follow-ups (improvement in percentage change OSDI [weeks 0-1, 0-4, and 1-4, P = 0.00], TBUT [weeks 0-1, P = 0.10; 0-4, P = 0.03; and 1-4, P = 0.04], and in ST [weeks 0-1, P = 0.007; 0-4, P = 0.03; and 1-4, P = 0.12]). No significant difference was found between Groups 2 and 3. Hydroxypropyl-guar containing PEG/PG and HPMC as tear substitutes are better than CMC. While HPMC was comparable to PEG/PG in subjective improvement, the objective improvement was not consistent.
The Role of Health Anxiety and Depressive Symptoms in Dry Eye Disease.
Szakáts, Ildikó; Sebestyén, Margit; Németh, János; Birkás, Emma; Purebl, György
2016-08-01
To investigate the associations between health anxiety, depressive and anxiety symptoms, and the severity of the subjective and objective symptoms of dry eye disease (DED). Participants completed the following psychological questionnaires: Shortened Health Anxiety Inventory, Shortened Beck Depression Inventory, and Beck Anxiety Inventory. Dry eye symptoms were evaluated using the ocular surface disease index (OSDI). Bilateral tear osmolarity measurement, tear film break-up time (TBUT), ocular surface staining, Schirmer 1 test, and meibomian gland dysfunction assessment were performed. Based on the OSDI score, 56 of the 84 participants enrolled were symptomatic and 28 asymptomatic. According to the objective parameters, 48/56 (85.7%) in the symptomatic group and 23/28 (82.1%) in the asymptomatic group were diagnosed with DED. In terms of the objective parameters, except for TBUT, there were no statistically significant differences between the symptomatic and asymptomatic group (p > 0.108), or between the subgroups with objectively proven dry eye (p > 0.233). The results of the psychological questionnaires were significantly worse in the symptomatic group (p < 0.01) and the symptomatic subgroup with objective dry eye (p < 0.05), than in the asymptomatic groups. In the overall study population the scores of the psychological questionnaires demonstrated significant positive correlations with the OSDI scores (r > 0.306, p < 0.01). These results support the role of health anxiety and of depressive and anxiety symptoms in DED, and may serve as an explanation for the lack of correlation between subjective symptoms and objective signs of the disease.
NASA Astrophysics Data System (ADS)
Ahmad, Naseer; Kamal, Shahid; Raza, Zulfiqar Ali; Hussain, Tanveer
2017-03-01
The present study investigated multi-response optimization of certain input parameters viz. concentrations of oil and water repellent finish (Oleophobol CP-C®), dimethylol dihydroxy ethylene urea based cross linking agent (Knittex FEL) and curing temperature on some mechanical, (i.e. tear and tensile strengths), functional (i.e., water contact angle ‘WCA’, oil contact angle ‘OCA’) and comfort (i.e. crease recovery angle ‘CRA’, air permeability ‘AP’, and stiffness) properties of an oleo-hydrophobic finished fabric under response surface methodology and the desirability function. The results have been examined using analysis of variance (ANOVA) and desirability function for the identification of optimum levels of input variables. The ANOVA was employed also to identify the percentage contribution of process factors. Under the optimized conditions, which were obtained with a total desirability value of 0.7769, the experimental values of Oleophobol CP-C® (O-CPC), Knittex FEL (K-FEL) and curing temperature (C-Temp) agreed closely with the predicted values. The optimized process parameters for maximum WCA (135°), OCA (129°), AP (290 m s-1), CRA (214°), tear (1492 gf) and tensile (764 N) strengths and minimum stiffness (3.2928 cm) were found to be: concentration of OCP-C as 44.44 g l-1, concentration of cross linker K-FEL as 32.07 g l-1 and C-Temp as 161.81 °C.
Cemental tear: To know what we have neglected in dental practice.
Jeng, Po-Yuan; Luzi, Arlinda Luzi; Pitarch, Rocio Marco; Chang, Mei-Chi; Wu, Yu-Hsueh; Jeng, Jiiang-Huei
2018-04-01
Cemental tear is a special kind of root surface fracture, contributing to periodontal and periapical breakdown. However, it is a challenge for doctors to diagnose, resulting in delayed or improper treatment. We reviewed the predisposing factors, location, radiographic/clinical characteristics, diagnosis and treatments of cemental tears. From the literature, patients with cemental tear were mainly males, over 60 year-old. Possible predisposing factors include gender, age, tooth type, traumatic occlusal force and vital teeth. Cemental tears were common in upper and lower anterior teeth, single or multiple, and can be present in cervical, middle and apical third of roots. Morphology of cemental tears can be either piece-shaped or U-shaped. Clinically, cemental tear shows a unitary periodontal pocket and signs/symptoms mimicking localized periodontitis, apical periodontitis and vertical root fractures. Treatment of cemental tears include scaling, root planning, root canal treatment, periodontal/periapical surgery, guided tissue regeneration, bone grafting, and intentional replantation. Recurrence of cemental tear is possible especially when the fracture involves root apex. Extraction is recommended for teeth with poor prognosis. In conclusion, cemental tears can involve both periodontal and periapical area. Dentists should understand the predisposing factors and clinical features of cemental tears for early diagnosis/treatment to prevent bone loss/tooth extraction. Copyright © 2017. Published by Elsevier B.V.
Effects of diquafosol sodium eye drops on tear film stability in short BUT type of dry eye.
Shimazaki-Den, Seika; Iseda, Hiroyuki; Dogru, Murat; Shimazaki, Jun
2013-08-01
To investigate the effects of diquafosol sodium (DQS) eye drops, a purinergic P2Y2 receptor agonist, on tear film stability in patients with unstable tear film (UTF). Two prospective studies were conducted. One was an exploratory nonrandomized trial on 39 eyes with dry eye symptoms and short tear film break-up time (BUT), but without epithelial damage. Changes in symptoms, BUT, Schirmer value, and ocular surface fluorescein staining (FS) scores were studied for 3 months. The other was a randomized clinical trial of DQS and artificial tears (AT) in 17 eyes with short BUT. Eyes with decreased Schirmer values (≤ 5 mm) were excluded. Changes in symptoms, BUT, FS scores, and tear film stability using continuous corneal topographic analysis were studied for 4 weeks. In the exploratory study, while Schirmer values were not significantly increased, significant improvements in symptoms and BUT were noted at both 1 and 3 months. In the randomized clinical trial, significant improvements in symptoms were noted in the DQS group, but not in the AT group, at 2 weeks. BUT was significantly prolonged in the DQS group at 4 weeks but not in the AT group. No significant changes were noted in FS scores or tear film stability. DQS improved subjective symptoms and prolonged BUT in eyes with UTF not associated with low tear secretion and ocular surface epithelial damage. Because many patients who have UTF are refractory to conventional treatments, DQS may offer benefits in the treatment of dry eyes.
In-vivo measurements of the tear film on a cornea and a contact lens by use of interferometry
NASA Astrophysics Data System (ADS)
Licznerski, Tomasz J.; Kasprzak, Henryk T.; Kowalik, Waldemar
1996-12-01
The tear film fulfills several important functions in the eye. Apart of its physiologic functions like maintaining a moist environment for the epithelial cells of the cornea and conjunctiva, bacterial properties, transporting metabolic products etc., this film causes that the corneal surface has the optical quality. This smooth surface allows to apply interferometry for measurements. The paper presents tear's layer distribution on the soft contact lens and the cornea in comparison. Tv frame speed registration in the Twyman- Green interferometer was used to observe an unstable biomedical objects like the eye. The proposed method has the advantage of being noncontact and applies the low energy laser beam in interferometric set-up. This provides non- invasive testing of human cornea in vivo and enables observation the kinetics of its tear layer deterioration. The evaluation of non-invasive tear breakup time is possible by use of proposed setup. Further analysis of recorded interferograms helps to examine the matter of the breakup process and can be used for detection of the 'dry eye' symptoms.
Zimmermann, N; Erb, C
2013-08-01
Matrix-metalloproteinases (MMPs) are proteolytic enzymes released by irritated epithelial cells of the ocular surface. It has been established that the subtype MMP-9 can serve as an inflammatory marker within the tear film. MMP-9 is also attributed to have an effect on the PEX-glaucoma development. Recently, a rapid immunoassay for detection of MMP-9 in the tear film was developed to estimate inflammatory extent during dry eye disease. The aim of this study was to analyse the MMP-9 concentration in tear film in PEX-syndrome. In addition, an assessment of the feasibility, reliability and readability of the test was done. We randomly selected 10 patients with PEX-syndrome and 10 healthy control patients and measured tear film MMP-9 of one eye with the RPS InflammaDry Detector™ (Rapid Pathogen Screening Inc., USA). We detected increased levels of MMP-9 in tear film in PEX-syndrome. 80 % of the PEX-patients and 20 % of the controls showed a positive test result (>or= 40 ng/mL MMP-9) indicating a test specificity and sensitivity of 80 %. This corresponds approximately to the published values for the dry eye (sensitivity 87 %, specificity: 92 %). The performance of the test is simple. The patients tolerated the inclusion of the test strips well. However, it is difficult to estimate whether enough tear film was used and in many cases, the intensity of the "indicator line" was weak. The rapid MMP-9-immunoassay is a novel, meaningful approach for the detection of inflammatory activity of the ocular surface. We have shown an up-regulation of the non-specific inflammatory marker MMP-9 in tear film in PEX-syndrome and suggest an association with a tear film disorder. However, an improvement in the estimation of the amount of collected tears and readability is desirable. Georg Thieme Verlag KG Stuttgart · New York.
Meniscal repair using the Polysorb Meniscal Stapler XLS.
Oberlander, Michael A; Chisar, Michael A
2005-09-01
We present our technique of repair of meniscal tears in 11 patients using a newly designed stapler, the Polysorb Meniscal Stapler XLS (USS Sports Medicine, Norwalk, CT), to increase the effectiveness and ease of repair of tears in the vascular zone while limiting potential complications. The low-profile stapler comes with a reloadable pistol grip device and a disposable straight or 15 degrees upcurved shaft with a single preloaded 10-mm staple. Standard anteromedial and anterolateral portals were used, along with a superomedial portal for inflow. The portal was enlarged slightly to facilitate introduction of the cannula or the stapler directly into the knee. The nose of the stapler was applied to the superior surface of the inner edge of the meniscal tear. The sharp points on the tip of the nose were used to manipulate the inner edge and coapt the tear site. Firm pressure was applied to the meniscal tissue, and the nose of the stapler was embedded in the inner edge of the meniscus no more than 2 to 3 mm from the tear (as measured along the meniscal surface). The handle was pulled slowly as the staple engaged the meniscal tissue. This step was repeated every 3 to 4 mm to ensure ideal tear stabilization.
Inic-Kanada, Aleksandra; Nussbaumer, Andrea; Montanaro, Jacqueline; Belij, Sandra; Schlacher, Simone; Stein, Elisabeth; Bintner, Nora; Merio, Margarethe; Zlabinger, Gerhard J.
2012-01-01
Purpose Evaluating cytokine profiles in tears could shed light on the pathogenesis of various ocular surface diseases. When collecting tears with the methods currently available, it is often not possible to avoid the tear reflex, which may give a different cytokine profile compared to basal tears. More importantly, tear collection with glass capillaries, the most widely used method for taking samples and the best method for avoiding tear reflex, is impractical for remote area field studies because it is tedious and time-consuming for health workers, who cannot collect tears from a large number of patients with this method in one day. Furthermore, this method is uncomfortable for anxious patients and children. Thus, tears are frequently collected using ophthalmic sponges. These sponges have the advantage that they are well tolerated by the patient, especially children, and enable standardization of the tear collection volume. The aim of this study was to compare various ophthalmic sponges and extraction buffers to optimize the tear collection method for field studies for subsequent quantification of cytokines in tears using the Luminex technology. Methods Three ophthalmic sponges, Merocel, Pro-ophta, and Weck-Cel, were tested. Sponges were presoaked with 25 cytokines/chemokines of known concentrations and eluted with seven different extraction buffers (EX1–EX7). To assess possible interference in the assay from the sponges, two standard curves were prepared in parallel: 1) cytokines of known concentrations with the extraction buffers and 2) cytokines of known concentrations loaded onto the sponges with the extraction buffers. Subsequently, a clinical assessment of the chosen sponge-buffer combination was performed with tears collected from four healthy subjects using 1) aspiration and 2) sponges. To quantify cytokine/chemokine recovery and the concentration in the tears, a 25-plex Cytokine Panel and the Luminex xMap were used. This platform enables simultaneous measurement of proinflammatory cytokines, Th1/Th2 distinguishing cytokines, nonspecific acting cytokines, and chemokines. Results We demonstrated the following: (i) 25 cytokines/chemokines expressed highly variable interactions with buffers and matrices. Several buffers enabled recovery of similar cytokine values (regulated and normal T cell expressed and secreted [RANTES], interleukin [IL]-13, IL-6, IL-8, IL-2R, and granulocyte-macrophage colony-stimulating factor [GM-CSF]); others were highly variable (monocyte chemotactic protein-1 [MCP-1], monokine induced by interferon-gamma [MIG], IL-1β, IL-4, IL-7, and eotaxin). (ii) Various extraction buffers displayed significantly different recovery rates on the same sponge for the same cytokine/chemokine. (iii) The highest recovery rates were obtained with the Merocel ophthalmic sponge except for tumor necrosis factor-α: the Weck-Cel ophthalmic sponge showed the best results, either with cytokine standards loaded onto sponges or with tears collected from the inner canthus of the eye, using the sponge. (iv) IL-5, IL-10, and interferon-α were not detected in any tear sample from four normal human subjects. Twenty-two cytokines/chemokines that we detected were extracted from the Merocel sponge to a satisfactory recovery percentage. The recovery of IL-7 was significantly lower in the extracted Merocel sponge compared to the diluted tear samples. The cytokine/chemokine extraction from tears showed the same pattern of extraction that we observed for extracting the standards. Conclusions Simultaneous measurement of various cytokines using ophthalmic sponges yielded diverse results for various cytokines as the level of extraction differs noticeably for certain cytokines. A second set of controls (standard curves “with sponges”) should be used to delineate the extent of extraction for each cytokine to be analyzed. Many cytokines/chemokines were detected in tear samples collected with the Merocel sponge, including many that have been implicated in ocular surface disease. Luminex detection of cytokine/chemokine profiles of tears collected with Merocel sponges and extracted with buffer EX1 may be useful in clinical studies, for example, to assess cytokine profiles evaluation in ocular surface diseases. PMID:23233782
Inic-Kanada, Aleksandra; Nussbaumer, Andrea; Montanaro, Jacqueline; Belij, Sandra; Schlacher, Simone; Stein, Elisabeth; Bintner, Nora; Merio, Margarethe; Zlabinger, Gerhard J; Barisani-Asenbauer, Talin
2012-01-01
Evaluating cytokine profiles in tears could shed light on the pathogenesis of various ocular surface diseases. When collecting tears with the methods currently available, it is often not possible to avoid the tear reflex, which may give a different cytokine profile compared to basal tears. More importantly, tear collection with glass capillaries, the most widely used method for taking samples and the best method for avoiding tear reflex, is impractical for remote area field studies because it is tedious and time-consuming for health workers, who cannot collect tears from a large number of patients with this method in one day. Furthermore, this method is uncomfortable for anxious patients and children. Thus, tears are frequently collected using ophthalmic sponges. These sponges have the advantage that they are well tolerated by the patient, especially children, and enable standardization of the tear collection volume. The aim of this study was to compare various ophthalmic sponges and extraction buffers to optimize the tear collection method for field studies for subsequent quantification of cytokines in tears using the Luminex technology. Three ophthalmic sponges, Merocel, Pro-ophta, and Weck-Cel, were tested. Sponges were presoaked with 25 cytokines/chemokines of known concentrations and eluted with seven different extraction buffers (EX1-EX7). To assess possible interference in the assay from the sponges, two standard curves were prepared in parallel: 1) cytokines of known concentrations with the extraction buffers and 2) cytokines of known concentrations loaded onto the sponges with the extraction buffers. Subsequently, a clinical assessment of the chosen sponge-buffer combination was performed with tears collected from four healthy subjects using 1) aspiration and 2) sponges. To quantify cytokine/chemokine recovery and the concentration in the tears, a 25-plex Cytokine Panel and the Luminex xMap were used. This platform enables simultaneous measurement of proinflammatory cytokines, Th1/Th2 distinguishing cytokines, nonspecific acting cytokines, and chemokines. WE DEMONSTRATED THE FOLLOWING: (i) 25 cytokines/chemokines expressed highly variable interactions with buffers and matrices. Several buffers enabled recovery of similar cytokine values (regulated and normal T cell expressed and secreted [RANTES], interleukin [IL]-13, IL-6, IL-8, IL-2R, and granulocyte-macrophage colony-stimulating factor [GM-CSF]); others were highly variable (monocyte chemotactic protein-1 [MCP-1], monokine induced by interferon-gamma [MIG], IL-1β, IL-4, IL-7, and eotaxin). (ii) Various extraction buffers displayed significantly different recovery rates on the same sponge for the same cytokine/chemokine. (iii) The highest recovery rates were obtained with the Merocel ophthalmic sponge except for tumor necrosis factor-α: the Weck-Cel ophthalmic sponge showed the best results, either with cytokine standards loaded onto sponges or with tears collected from the inner canthus of the eye, using the sponge. (iv) IL-5, IL-10, and interferon-α were not detected in any tear sample from four normal human subjects. Twenty-two cytokines/chemokines that we detected were extracted from the Merocel sponge to a satisfactory recovery percentage. The recovery of IL-7 was significantly lower in the extracted Merocel sponge compared to the diluted tear samples. The cytokine/chemokine extraction from tears showed the same pattern of extraction that we observed for extracting the standards. Simultaneous measurement of various cytokines using ophthalmic sponges yielded diverse results for various cytokines as the level of extraction differs noticeably for certain cytokines. A second set of controls (standard curves "with sponges") should be used to delineate the extent of extraction for each cytokine to be analyzed. Many cytokines/chemokines were detected in tear samples collected with the Merocel sponge, including many that have been implicated in ocular surface disease. Luminex detection of cytokine/chemokine profiles of tears collected with Merocel sponges and extracted with buffer EX1 may be useful in clinical studies, for example, to assess cytokine profiles evaluation in ocular surface diseases.
Lee, Hyung Keun; Lee, Kyung Sub; Kim, Hyeon Chang; Lee, Sung Ho; Kim, Eung Kweon
2005-06-01
To determine whether tear nerve growth factor (NGF) concentration correlates with corneal sensation and ocular surface dryness after photorefractive keratectomy (PRK) and laser in situ keratomileusis (LASIK). Prospective, nonrandomized comparative clinical trial. Seventy eyes of 35 patients and 76 eyes of 38 patients underwent PRK and LASIK procedures to correct myopia and myopic astigmatism, respectively. Total tear protein level, tear NGF concentration, tear film breakup time (BUT) and Schirmer values were measured before and 1 day, 1 week, 1 month, 3 months, and 6 months after surgery. The postoperative mean tear NGF/total tear protein (NGF/tP) ratio increased in both PRK and LASIK patients compared with preoperative levels (P < .0001). At 1 week and 1 month postoperatively, the NGF/tP ratio was higher in PRK than in LASIK subjects (P < .0001). Before 6 months postoperatively, the mean corneal sensation after LASIK in the ablated zone was lower than the preoperative sensation (P < .0001), but this was not the case in PRK subjects. Mean BUT and Schirmer values were significantly lower in LASIK-treated eyes compared with PRK-treated eyes up to 6 months postoperatively (P < .0001). The early postoperative tear NGF/tP ratio correlated with the postoperative 6-month value of corneal sensation, BUT, and Schirmer values. The difference in the postoperative corneal sensation and ocular surface dryness between PRK-treated and LASIK-treated eyes might be related to the difference in the early postoperative levels of NGF, which is a potent nerve growth stimulator.
Duplex Tear Film Evaporation Analysis.
Stapf, M R; Braun, R J; King-Smith, P E
2017-12-01
Tear film thinning, hyperosmolarity, and breakup can cause irritation and damage to the human eye, and these form an area of active investigation for dry eye syndrome research. Recent research demonstrates that deficiencies in the lipid layer may cause locally increased evaporation, inducing conditions for breakup. In this paper, we explore the conditions for tear film breakup by considering a model for tear film dynamics with two mobile fluid layers, the aqueous and lipid layers. In addition, we include the effects of osmosis, evaporation as modified by the lipid, and the polar portion of the lipid layer. We solve the system numerically for reasonable parameter values and initial conditions and analyze how shifts in these cause changes to the system's dynamics.
Li, Longfei; Braun, R. J.; Maki, K. L.; Henshaw, W. D.; King-Smith, P. E.
2014-01-01
We study tear film dynamics with evaporation on a wettable eye-shaped ocular surface using a lubrication model. The mathematical model has a time-dependent flux boundary condition that models the cycles of tear fluid supply and drainage; it mimics blinks on a stationary eye-shaped domain. We generate computational grids and solve the nonlinear governing equations using the OVERTURE computational framework. In vivo experimental results using fluorescent imaging are used to visualize the influx and redistribution of tears for an open eye. Results from the numerical simulations are compared with the experiment. The model captures the flow around the meniscus and other dynamic features of human tear film observed in vivo. PMID:24926191
Improvements in Signs and Symptoms of Dry Eye after Instillation of 2% Rebamipide.
Igarashi, Tsutomu; Fujita, Miho; Yamada, Yumi; Kobayashi, Maika; Fujimoto, Chiaki; Takahashi, Hisatomo; Igarashi, Toru; Nakano, Yuichiro; Suzuki, Hisaharu; Takahashi, Hiroshi
2015-01-01
Because dry eye greatly reduces quality of life, this study aimed to examine rebamipide instillation in patients with dry eye and assess the improvement of signs and symptoms as evaluated with the Ocular Surface Disease Index, which is the most popular index and is highly reliable. From June 2013 through January 2014, we examined 50 eyes of 25 patients with dry eye (6 men and 19 woman) at our institution. Dry eye was diagnosed on the basis of the presence of symptoms, tear dynamics, and ocular surface abnormalities according to the Japanese criteria for dry eye. Before being enrolled, all patients underwent ocular surface health assessment, including history interviews, and completed the Ocular Surface Disease Index questionnaire. Patients received 2% rebamipide ophthalmic solution 4 times daily for 4 weeks. Signs and symptoms were analyzed before and 4 weeks after rebamipide administration. Tear dynamics, tear break-up time, and ocular surface abnormalities were measured and compared between before and 4 weeks after rebamipide administration. Of the 25 patients, 9 had definite dry eye and 16 had probable dry eye. Tear break-up time and the fluorescein staining score significantly improved after 4 weeks. However, no significant change was observed for the Schirmer test I and the lissamine green staining score. The administration of 2% rebamipide 4 times daily for 4 weeks improves the signs and symptoms of dry eye and improves patients' quality of life.
Solute Dynamics and Imaging in the Tear Film on an Eye-shaped Domain
NASA Astrophysics Data System (ADS)
Braun, R. J.; Li, Longfei; Henshaw, William; Driscoll, Tobin; King-Smith, P. E.
2015-11-01
The concentration of ions in the tear film (osmolarity) is a key variable in understanding dry eye symptoms and disease, yet its global distribution is not available; direct measurements are restricted to a region near the temporal canthus. It has been suggested that imaging methods that use solutes such as fluorescein can be used as a proxy for estimating the osmolarity. The concentration of fluorescein is not measured directly either but the intensity as a function of concentration and thickness of the film is well established. We derived a mathematical model that couples multiple solutes and fluid dynamics within the tear film on a 2D eye-shaped domain. The model includes the physical effects of evaporation, surface tension, viscosity, ocular surface wettability, osmolarity, osmosis, fluorescence and tear fluid supply and drainage. We solved the governing system of coupled nonlinear PDEs using the Overture computational framework developed at LLNL, together with a hybrid time stepping scheme (using variable step BDF and RKC). Results of our numerical simulations provide new insight about the osmolarity distribution and its connection with images obtained in vivo over the whole ocular surface and in local regions of tear thinning due to evaporation and other effects. This work was supported in part by NSF grants 1022706 and 1412085, and NIH grant 1R01EY021794.
Joossen, Cedric; Lanckacker, Ellen; Zakaria, Nadia; Koppen, Carina; Joossens, Jurgen; Cools, Nathalie; De Meester, Ingrid; Lambeir, Anne-Marie; Delputte, Peter; Maes, Louis; Cos, Paul
2016-05-01
The aim of this research was to optimize and validate an animal model for dry eye, adopting clinically relevant evaluation parameters. Dry eye was induced in female Wistar rats by surgical removal of the exorbital lacrimal gland. The clinical manifestations of dry eye were evaluated by tear volume measurements, corneal fluorescein staining, cytokine measurements in tear fluid, MMP-9 mRNA expression and CD3(+) cell infiltration in the conjunctiva. The animal model was validated by treatment with Restasis(®) (4 weeks) and commercial dexamethasone eye drops (2 weeks). Removal of the exorbital lacrimal gland resulted in 50% decrease in tear volume and a gradual increase in corneal fluorescein staining. Elevated levels of TNF-α and IL-1α have been registered in tear fluid together with an increase in CD3(+) cells in the palpebral conjunctiva when compared to control animals. Additionally, an increase in MMP-9 mRNA expression was recorded in conjunctival tissue. Reference treatment with Restasis(®) and dexamethasone eye drops had a positive effect on all evaluation parameters, except on tear volume. This rat dry eye model was validated extensively and judged appropriate for the evaluation of novel compounds and therapeutic preparations for dry eye disease. Copyright © 2016 Elsevier Ltd. All rights reserved.
The effects of Ramadan fasting on the health and function of the eye.
Javadi, Mohammad Ali; Assadi, Mahsan; Einollahi, Bahram; Rabei, Hossein Mohammad; Afarid, Mehrdad; Assadi, Majid
2014-08-01
Ramadan fasting may alter a variety of physiological parameters which by themselves influence ocular system. Here, we review the effects of Ramadan fasting on the health and function of the eye. Literature records in PubMed/MEDLINE, Web of Science, EMBASE, Google Scholar, and Iran Medex databases as well as proceedings of related meetings from January 1986 to March 2014 were systematically reviewed. The search key words was based on the terms "Ramadan Fasting," "Ramadan," "Islamic Fasting," "Fasting in Ramadan" accompanied with one of the eye, tear drop, myopia, intraocular pressure (IOP), tear break up time, basal tear secretion, refractive error, and visual acuity. Predawn water loading and dehydration in the evening are shown to increase and decrease IOP and tear secretion, respectively. Ocular blood flow is changed in Ramadan fasting, and patients with ocular vein occlusion may experience more frequent attacks. There are no or minimal fluctuations in visual acuity and refractive errors, but most of them are decompensated after Ramadan. Although the influence of fasting in different eye parameters is evaluated in several studies, there are no or only limited studies conducted on patients suffering from glaucoma, damage to ophthalmic vasculature, tear dysfunction, and minimal visual acuity. Such studies are required to make a definite decision before fasting is declared harmless to these patients.
Localized tearing modes in the magnetotail driven by curvature effects
NASA Technical Reports Server (NTRS)
Sundaram, A. K.; Fairfield, D. H.
1995-01-01
The stability of collisionless tearing modes is examined in the presence of curvature drift resonances and the trapped particle effects. A kinetic description for both electrons and ions is employed to investigate the stability of a two-dimensional equilibrium model. The main features of the study are to treat the ion dynamics properly by incorporating effects associated with particle trajectories in the tail fields and to include the linear coupling of trapped particle modes. Generalized dispersion relations are derived in several parameter regimes by considering two important sublayers of the reconnecting region. For a typical choice of parameters appropriate to the current sheet region, we demonstrate that localized tearing modes driven by ion curvature drift resonance effects are excited in the current sheet region with growth time of the order of a few seconds. Also, we examine nonlocal characteristics of tearing modes driven by curvature effects and show that modes growing in a fraction of a second arise when mode widths are larger than the current sheet width. Further, we show that trapped particle effects, in an interesting frequency regime, significantly enhance the growth rate of the tearing mode. The relevance of this theory for substorm onset phase and other features of the substorms is briefly discussed.
Interaction of lysozyme with a tear film lipid layer model: A molecular dynamics simulation study.
Wizert, Alicja; Iskander, D Robert; Cwiklik, Lukasz
2017-12-01
The tear film is a thin multilayered structure covering the cornea. Its outermost layer is a lipid film underneath of which resides on an aqueous layer. This tear film lipid layer (TFLL) is itself a complex structure, formed by both polar and nonpolar lipids. It was recently suggested that due to tear film dynamics, TFLL contains inhomogeneities in the form of polar lipid aggregates. The aqueous phase of tear film contains lachrymal-origin proteins, whereby lysozyme is the most abundant. These proteins can alter TFLL properties, mainly by reducing its surface tension. However, a detailed nature of protein-lipid interactions in tear film is not known. We investigate the interactions of lysozyme with TFLL in molecular details by employing coarse-grained molecular dynamics simulations. We demonstrate that lysozyme, due to lateral restructuring of TFLL, is able to penetrate the tear lipid film embedded in inverse micellar aggregates. Copyright © 2017 Elsevier B.V. All rights reserved.
Kan, Emrah; Kan, Elif K; Okuyucu, Ali
2017-08-30
To compare the central corneal thickness (CCT), intraocular pressure (IOP), and tear insulin-like growth factor 1 (IGF-1) levels between patients with acromegaly and a control group and to evaluate the possible effect of tear IGF-1 and duration of the disease on CCT and IOP. We included 31 patients with acromegaly (study group) and 40 age- and sex-matched controls in the study. Patients with acromegaly were divided into 2 subgroups based on disease status (active/inactive). All participants underwent complete ophthalmologic evaluation including CCT and IOP values. Basal tear samples were collected from both groups and tear IGF-1 levels were measured. The CCT, IOP, and tear IGF-1 levels were compared between groups and subgroups and the association between tear IGF-I levels and ocular parameters (CCT, IOP) and disease duration were also evaluated. Central corneal thickness, IOP, and tear IGF-1 levels did not show a significant difference between study and control groups. We also did not find a significant difference in terms of CCT, IOP, or tear IGF-1 levels between subgroups of patients. Correlation analysis did not show an association between the duration of disease and tear IGF-1 levels with CCT or IOP. There was no significant difference in tear IGF-1 levels between patients with acromegaly and controls. Additionally, there was no correlation between disease duration and tear IGF-1 levels with CCT or IOP levels. This lack of association may suggest that tear IGF-1 levels might not have an effect on CCT or IOP findings in patients with acromegaly.
Petznick, Andrea; Madigan, Michele C; Garrett, Qian; Sweeney, Deborah F; Evans, Margaret D M
2013-01-01
This study investigated ocular surface components that contribute to matrix-metalloproteinase (MMP)-2 and MMP-9 found in tears following corneal epithelial wounding. Laboratory short-haired cats underwent corneal epithelial debridement in one randomly chosen eye (n = 18). Eye-flush tears were collected at baseline and during various healing stages. Procedural control eyes (identical experimental protocol as wounded eyes except for wounding, n = 5) served as controls for tear analysis. MMP activity was analyzed in tears using gelatin zymography. MMP staining patterns were evaluated in ocular tissues using immunohistochemistry and used to determine MMP expression sites responsible for tear-derived MMPs. The proMMP-2 and proMMP-9 activity in tears was highest in wounded and procedural control eyes during epithelial migration (8 to 36 hours post-wounding). Wounded eyes showed significantly higher proMMP-9 in tears only during and after epithelial restratification (day 3 to 4 and day 7 to 28 post-wounding, respectively) as compared to procedural controls (p<0.05). Tears from wounded and procedural control eyes showed no statistical differences for pro-MMP-2 and MMP-9 (p>0.05). Immunohistochemistry showed increased MMP-2 and MMP-9 expression in the cornea during epithelial migration and wound closure. The conjunctival epithelium exhibited highest levels of both MMPs during wound closure, while MMP-9 expression was reduced in conjunctival goblet cells during corneal epithelial migration followed by complete absence of the cells during wound closure. The immunostaining for both MMPs was elevated in the lacrimal gland during corneal healing, with little/no change in the meibomian glands. Conjunctival-associated lymphoid tissue (CALT) showed weak MMP-2 and intense MMP-9 staining. Following wounding, migrating corneal epithelium contributed little to the observed MMP levels in tears. The major sources assessed in the present study for tear-derived MMP-2 and MMP-9 following corneal wounding are the lacrimal gland and CALT. Other sources included stromal keratocytes and conjunctiva with goblet cells.
Zhang, Hui; Wang, Yan
2017-09-22
To investigate the dry eye after small incision lenticule extraction (SMILE) and explore the correlations between changes in the tear film stability, the tear secretion and the corneal surface regularity. Sixty-two eyes of 22 men and 13 women who underwent SMILE were included in this study. Corneal topography was measured to assess the index of surface variance (ISV) and the index of vertical asymmetry (IVA). Dry eye tests including subjective symptom questionnaire, tear breakup time (TBUT), corneal fluorescein staining and Schirmer's test (ST) were evaluated before and at 1 and 6 months postoperatively. TBUT was found to be significantly decreased from 9.8 ± 3.4 s preoperatively to 7.4 ± 3.8 s at 1 month and 6.5 ± 3.6 s at 6 months (both P < 0.001). There was a significant decrease in ST at 1 month postoperatively (P = 0.012); however, ST returned to baseline by 6 months (P = 0.522). Both ISV and IVA significantly increased after the surgery (all P < 0.001). In addition, the changes in TBUT were negatively correlated with the increases in ISV and IVA (r = -0.343, P = 0.006 and r = -0.311, P = 0.014, respectively). Patients undergoing SMILE might develop a short-TBUT type of dry eye. Corneal surface regularity indices might be helpful in the assessment of tear film stability following SMILE procedure.
Posa, Andreas; Paulsen, Friedrich; Dietz, Richard; Garreis, Fabian; Sander, Ralph; Schicht, Martin; Sel, Saadettin; Scholz, Michael; Hammer, Christian M; Bräuer, Lars
2018-03-01
To quantify and compare the amounts of surfactant proteins SP-A, SP-B, SP-C and SP-D in the tear fluid collected from patients with dry eye syndrome and from individuals with a healthy ocular surface. Schirmer strips were used to collect tear fluid from both eyes of 241 volunteers (99 men, 142 women; age range: 18-87 years). Dry eye syndrome was diagnosed by ophthalmologists in 125 patients, whereas the healthy control group comprised 116 individuals. The total protein concentration was determined via Bradford assay. The relative concentration of surfactant proteins SP-A through -D was measured by enzyme-linked immuno-sorbent assay (ELISA). The mean relative concentrations of SP-A, SP-C and SP-D were significantly higher in the dry eye group as compared to the healthy controls (p<0.05, one-way ANOVA). SP-B was also detected at a higher concentration in the dry eye group, but the difference to the control group was not statistically significant. The upregulation of SP-A and SP-D in the dry eye group is probably related to these proteins' known antimicrobial and immunomodulatory effects at the ocular surface. It may represent a pathophysiological response to the inflammatory condition of the ocular surface in dry eye. The upregulation of SP-B and SP-C may represent an effort of the lacrimal system to reduce surface tension and thus to counteract the increased tendency of the tear film to tear in dry eye. Copyright © 2017 Elsevier GmbH. All rights reserved.
New testing options for diagnosing and grading dry eye disease.
Foulks, Gary N; Pflugfelder, Stephen C
2014-06-01
To describe new options for diagnosis and severity grading of dry eye disease. Perspective on technological advancements to identify tear dysfunction and their value in diagnosing and grading dry eye disease. Evidence is presented on new and evolving technologies to measure tear stability, composition, and meniscus height and their role in dry eye diagnosis and therapeutic efficacy grading is assessed. Evolving concepts regarding pathogenesis and new technologies to evaluate the tears and ocular surface have improved the ability to diagnose, classify, and grade the severity of dry eye disease. New technologies include noninvasive imaging of tear stability and tear meniscus height as a measure of tear volume and tear composition (osmolarity, lacrimal factors, inflammatory mediators, growth and differentiation factors). Approved tests, such as tear osmolarity and tear imaging, are being integrated into clinical practice and may eventually supplant certain traditional tests that have greater variability and less sensitivity. Other tests, such as molecular assays of tears and conjunctival cells, are currently being used in studies investigating pathogenesis and therapeutic mechanism of action. They may eventually translate to routine clinical practice. New technologies have emerged that can noninvasively evaluate the tears and measure disease-associated compositional changes. These tests are being integrated into clinical practice and therapeutic trials for diagnosis, classification, and severity grading of dry eye disease. Copyright © 2014 Elsevier Inc. All rights reserved.
Unstable domains of tearing and Kelvin-Helmholtz instabilities in a rotating cylindrical plasma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fan, D. M.; Wei, L.; Wang, Z. X., E-mail: zxwang@dlut.edu.cn
2014-09-15
Effects of poloidal rotation profile on tearing and Kelvin-Helmholtz (KH) instabilities in a cylindrical plasma are investigated by using a reduced magnetohydrodynamic model. Since the poloidal rotation has different effects on the tearing and KH modes in different rotation regimes, four unstable domains are numerically identified, i.e., the destabilized tearing mode domain, stabilized tearing mode domain, stable-window domain, and unstable KH mode domain. It is also found that when the rotation layer is in the outer region of the rational surface, the stabilizing role of the rotation can be enhanced so significantly that the stable window domain is enlarged. Moreover,more » Alfvén resonances can be induced by the tearing and KH modes in such rotating plasmas. Radially wide profiles of current and vorticity perturbations can be formed when multiple current sheets on different resonance positions are coupled together.« less
Scuderi, Gianluca; Contestabile, Maria Teresa; Gagliano, Caterina; Iacovello, Daniela; Scuderi, Luca; Avitabile, Teresio
2012-12-01
To evaluate the correlation between tear osmolarity and blood levels of 17-β estradiol, estrone, and testosterone in postmenopausal women with dry eye syndrome, and to assess the efficacy and safety of oral supplementation with phytoestrogens, lipoic acid, and eicosapentaenoic acid in this population. Cross-sectional study including 66 postmenopausal women with dry eye syndrome. Sixty-six postmenopausal women with dry eye syndrome were enrolled in a randomized, double-blind, placebo-controlled, crossover study. Patients were divided into 2 groups (groups A and B) and treated, respectively, with phytoestrogen (Bioos, Montegiorgio, Italy) tablets or placebo tablets for 30 days. The 2 treatment periods were separated by a 30-day washout. Patients were examined on days 0 and 30 of each period. Assessments included blood levels of sex hormones, the Schirmer test for tear production, and measurement of tear osmolarity and tear film break-up time. At baseline, all patients had low sex hormone levels, which were correlated with high tear film osmolarity values (r = -0.59,-0.61,-0.58, respectively). After 30 days of therapy, the group treated with Lacrisek® (Bioos) had significantly decreased tear osmolarity (P<0.005) and significantly increased tear production evaluated with the Schirmer test and tear film break-up time values (P<0.001) compared with the placebo-treated group. Our study confirms that steroid hormones play an important role in ocular surface equilibrium and functions. Consequently, reduced blood levels of these hormones can produce changes at the ocular surface. Phytoestrogen supplementation can significantly improve the signs and symptoms of dry eye syndrome in postmenopausal women. Copyright © 2012 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.
Napoli, Pietro Emanuele; Satta, Giovanni Maria; Coronella, Franco; Fossarello, Maurizio
2014-07-01
To analyze in vivo the dynamic changes induced by different artificial tears (ATs) in the precorneal tear film (PCTF) and lower tear meniscus (LTM) by using spectral-domain (SD) anterior segment optical coherence tomography (OCT). We prospectively examined 42 normal human eyes by using SD-OCT imaging. On the day before OCT imaging, all enrolled subjects were evaluated for abnormalities of ocular surface. All tear film images were obtained before and after instillation of three different types of ATs (mucomimetic, lipid-based, and saline) in five serial scans: immediately (within 30 seconds), at the first, fifth, 10th, and 20th minute. Subjects received a drop of 35 μL in one randomly selected eye. All examinations were conducted in the same conditions of temperature, brightness, humidity, and time of day. Changes in the morphological pattern of both LTM and PCTF were associated with the type of artificial tear instilled on the ocular surface. Similarly, the radius of curvature (rc), the height (h), and the depth (d) showed dynamic variations depending on treatment. Although by the 20th minute, both h and d returned to baseline values in all groups, a significant difference in rc (compared with baseline) was detected for mucomimetic ATs (P = 0.04) and lipid ATs (P = 0.02). Spectral-domain OCT imaging has preliminarily proved to be a noninvasive tool to evaluate, in real time, the different changes induced by ATs instillation. An important stride in understanding the clinical response to various tear substitutes can be achieved by this objective and quantitative approach. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
Vardhan, Prabhakar; Dhiman, Kartar Singh
2014-01-01
Dry eye syndrome (DES) is a common ophthalmic problem predominantly affecting middle-aged and elderly people. It is a disease of deficient or deranged tears and ocular surface disorder producing symptoms of discomfort, visual disturbance, and tears film instability. Shushkakshipaka, an etymologically and clinically similar entity to DES, is defined in Ayurveda as the disease affecting all parts of the eye characterized by Paka (inflammation) due to Shuskatva (dryness) caused by altered coherence of Ashru (tears) with ocular surface or due to lack of Ashru. To compare the effect of Keshanjana and Netra Parisheka in Shushkakshipaka with artificial tear drops (carboxy methyl cellulose [CMC]). To search a safe, potent and cost-effective Ayurvedic treatment for DES, a randomized comparative clinical trial was conducted on 32 patients. Patients were divided in two groups 15 in group I and 17 in group II. Group I treated with artificial tear drop four times a day for topical use and group II treated with combination therapy of Keshanjana applied topically once a day and Netra Prisheka was done thrice a day. The effect of Ayurvedic management was found to be equivalent to the standard therapy, although the trial drugs provided more relief in foreign body sensation, burning sensation, dryness, pain, photophobia, itching, crusting, stuck eyelids, tear meniscus, conjunctival congestion, Schirmer I test, and tear film break-up time (TUBT). The standard therapy provided more relief than trial drugs in mucous discharges, transiently blurred vision, redness, and the presence of mucin debris in tear film. Keshanjana and Netra Parisheka can be used as a potent, safe and cost-effective treatment to ameliorate the symptoms of DES.
Vardhan, Prabhakar; Dhiman, Kartar Singh
2014-01-01
Background: Dry eye syndrome (DES) is a common ophthalmic problem predominantly affecting middle-aged and elderly people. It is a disease of deficient or deranged tears and ocular surface disorder producing symptoms of discomfort, visual disturbance, and tears film instability. Shushkakshipaka, an etymologically and clinically similar entity to DES, is defined in Ayurveda as the disease affecting all parts of the eye characterized by Paka (inflammation) due to Shuskatva (dryness) caused by altered coherence of Ashru (tears) with ocular surface or due to lack of Ashru. Aim: To compare the effect of Keshanjana and Netra Parisheka in Shushkakshipaka with artificial tear drops (carboxy methyl cellulose [CMC]). Materials and Methods: To search a safe, potent and cost-effective Ayurvedic treatment for DES, a randomized comparative clinical trial was conducted on 32 patients. Patients were divided in two groups 15 in group I and 17 in group II. Group I treated with artificial tear drop four times a day for topical use and group II treated with combination therapy of Keshanjana applied topically once a day and Netra Prisheka was done thrice a day. Results: The effect of Ayurvedic management was found to be equivalent to the standard therapy, although the trial drugs provided more relief in foreign body sensation, burning sensation, dryness, pain, photophobia, itching, crusting, stuck eyelids, tear meniscus, conjunctival congestion, Schirmer I test, and tear film break-up time (TUBT). The standard therapy provided more relief than trial drugs in mucous discharges, transiently blurred vision, redness, and the presence of mucin debris in tear film. Conclusion: Keshanjana and Netra Parisheka can be used as a potent, safe and cost-effective treatment to ameliorate the symptoms of DES. PMID:26664237
Napoli, Pietro Emanuele; Coronella, Franco; Satta, Giovanni Maria; Fossarello, Maurizio
2014-01-01
The aim of this work was to gather preliminary data in different conditions of healthy eyes, aqueous tear deficient dry eyes, obstructive meibomian gland disease (MGD) and non-obvious obstructive MGD (NOMGD) individuals, using a new, contrast-enhanced optical coherence tomography (OCT) imaging method to evaluate the clearance of lipids in human tears. Eighty-two adult patients presenting with complaints of ocular irritation were studied for abnormalities of the ocular surface and classified as healthy (n = 21), aqueous tear deficient dry eyes (n = 20), obstructive MGD (n = 15) and NOMGD (n = 26) individuals. A lipid-based tracer, containing an oil-in-water emulsion, was used to obtain an enhanced OCT imaging of the lower tear meniscus. After instillation, a dramatic initial increase of reflectivity of the lower tear meniscus was detected by OCT, followed by a decay back to baseline values over time. Based on this finding, the clearance of lipids was measured in real-time by Fourier-domain anterior segment OCT. The differences in the clearance of lipids among the four groups as well as the correlations between symptom questionnaire score, standardized visual scale test, fluorescein break-up time, ocular surface fluorescein staining score, Schirmer I test scores were found to be statistically significant. The individual areas under the curve of the clearance of lipids calculated by the receiver operating characteristic curve technique ranged from 0.66 to 0.98, suggesting reliable sensitivity and specificity of lipid-enhanced OCT imaging. This new technique of contrast-enhanced OCT imaging of the tear film following lipid-based tracer instillation provides a measure of the clearance of lipids. The quantitative values found are in agreement with other methods of evaluation of the lacrimal system. An improvement of the clinician's ability in the diagnosis and understanding of abnormalities of the ocular surface may be achieved by this simple approach.
... your joints. The most common location for a sprain is in your ankle. A strain is a stretching or tearing of ... tear a ligament while severely stressing a joint. Sprains often occur in the following circumstances: Ankle — Walking or exercising on an uneven surface Knee — ...
The growth of the tearing mode - Boundary and scaling effects
NASA Technical Reports Server (NTRS)
Steinolfson, R. S.; Van Hoven, G.
1983-01-01
A numerical model of resistive magnetic tearing is developed in order to verify and relate the results of the principal approximations used in analytic analyses and to investigate the solutions and their growth-rate scalings over a large range of primary parameters which include parametric values applicable to the solar atmosphere. The computations cover the linear behavior for a variety of boundary conditions, emphasizing effects which differentiate magnetic tearing in astrophysical situations from that in laboratory devices. Eigenfunction profiles for long and short wavelengths are computed and the applicability of the 'constant psi' approximation is investigated. The growth rate is computed for values of the magnetic Reynolds number up to a trillion and of the dimensionless wavelength parameter down to 0.001. The analysis predicts significant effects due to differing values of the magnetic Reynolds number.
Lacritin and Other New Proteins of the Lacrimal Functional Unit
McKown, Robert L.; Wang, Ningning; Raab, Ronald W.; Karnati, Roy; Zhang, Yinghui; Williams, Patricia B.; Laurie, Gordon W.
2009-01-01
The lacrimal functional unit (LFU) is defined by the 2007 International Dry Eye WorkShop as ‘an integrated system comprising the lacrimal glands, ocular surface (cornea, conjunctiva and meibomian glands) and lids, and the sensory and motor nerves that connect them’. The LFU maintains a healthy ocular surface primarily through a properly functioning tear film that provides protection, lubrication, and an environment for corneal epithelial cell renewal. LFU cells express thousands of proteins. Over two hundred new LFU proteins have been discovered in the last decade. Lacritin is a new LFU-specific growth factor in human tears that flows through ducts to target corneal epithelial cells on the ocular surface. When applied topically in rabbits, lacritin appears to increase the volume of basal tear secretion. Lacritin is one of only a handful of tear proteins preliminarily reported to be downregulated in blepharitis and in two dry eye syndromes. Computational analysis predicts an ordered C-terminal domain that binds the corneal epithelial cell surface proteoglycan syndecan-1 (SDC1) and is required for lacritin’s low nanomolar mitogenic activity. The lacritin binding site on the N-terminus of SDC1 is exposed by heparanase. Heparanase is constitutively expressed by the corneal epithelium and appears to be a normal constituent of tears. Binding triggers rapid signaling to downstream NFAT and mTOR. A wealth of other new proteins, originally designated as hypothetical when first identified by genomic sequencing, are expressed by the human LFU including: ALS2CL, ARHGEF19, KIAA1109, PLXNA1, POLG, WIPI1 and ZMIZ2. Their demonstrated or implied roles in human genetic disease or basic cellular functions are fuel for new investigation. Addressing topical areas in ocular surface physiology with new LFU proteins may reveal interesting new biological mechanisms and help get to the heart of ocular surface dysfunction. PMID:18840430
Rotator cuff tears in children and adolescents: experience at a large pediatric hospital.
Zbojniewicz, Andrew M; Maeder, Matthew E; Emery, Kathleen H; Salisbury, Shelia R
2014-06-01
Prior literature, limited to small case series and case reports, suggests that rotator cuff tears are rare in adolescents. However, we have identified rotator cuff tears in numerous children and adolescents who have undergone shoulder MRI evaluation. The purpose of this study is to describe the prevalence and characteristics of rotator cuff tears in children and adolescents referred for MRI evaluation of the shoulder at a large pediatric hospital and to correlate the presence of rotator cuff tears with concurrent labral pathology, skeletal maturity and patient activity and outcomes. We reviewed reports from 455 consecutive non-contrast MRI and magnetic resonance arthrogram examinations of the shoulder performed during a 2-year period, and following exclusions we yielded 205 examinations in 201 patients (ages 8-18 years; 75 girls, 126 boys). Rotator cuff tears were classified by tendon involved, tear thickness (partial or full), surface and location of tear (when partial) and presence of delamination. We recorded concurrent labral pathology when present. Physeal patency of the proximal humerus was considered open, closing or closed. Statistical analysis was performed to evaluate for a relationship between rotator cuff tears and degree of physeal patency. We obtained patient activity at the time of injury, surgical reports and outcomes from clinical records when available. Twenty-five (12.2%) rotator cuff tears were identified in 17 boys and 7 girls (ages 10-18 years; one patient had bilateral tears). The supraspinatus tendon was most frequently involved (56%). There were 2 full-thickness and 23 partial-thickness tears with articular-side partial-thickness tears most frequent (78%). Insertional partial-thickness tears were more common (78%) than critical zone tears (22%) and 10 (43%) partial-thickness tears were delamination tears. Nine (36%) patients with rotator cuff tears had concurrent labral pathology. There was no statistically significant relationship between rotator cuff tears and physeal patency (P > 0.05). Most patients were athletes (76%). Five tears were confirmed at surgery. Poor clinical follow-up limited evaluation of patient outcomes. Rotator cuff tears can be identified during MRI examination of symptomatic child and adolescent shoulders and often consist of tear patterns associated with repetitive microtrauma in overhead athletic activities or with single traumatic events. Rotator cuff tears are seen throughout the range of skeletal maturity, often coexist with labral tears and typically are found in athletes.
NASA Astrophysics Data System (ADS)
Rathore, Prerana; Sharma, Vivek
`Tears of wine' refer to the rows of wine-drops that spontaneously emerge within a glass of strong wine. Evaporation-driven Marangoni flows near the meniscus of water-alcohol mixtures drive liquid upward forming a thin liquid film, and a rim or ridge forms near the moving contact line. Eventually the rim undergoes an instability forming drops, that roll back into bulk reservoir forming so called tears or legs of wine. Most studies in literature argue the evaporation of more volatile, lower surface tension component (alcohol) results in a concentration-dependent surface tension gradient that drives the climbing flow within the thin film. Though it is well-known that evaporative cooling can create temperature gradients that could provide additional contribution to the climbing flows, the role of thermocapillary flows is less well-understood. Furthermore, the patterns, flows and instabilities that occur near the rim, and determine the size and periodicity of tears, are not well-studied. Using experiments and theory, we visualize and analyze the formation and growth of tears of wine. The sliding drops, released from the rim towards the bulk reservoir, show oscillations and a cascade of fascinating flows that are analyzed for the first time.
NASA Astrophysics Data System (ADS)
Jenkins, Thomas G.; Kruger, Scott E.; Hegna, C. C.; Schnack, Dalton D.; Sovinec, Carl R.
2010-01-01
A model which incorporates the effects of electron cyclotron current drive (ECCD) into the magnetohydrodynamic equations is implemented in the NIMROD code [C. R. Sovinec et al., J. Comput. Phys. 195, 355 (2004)] and used to investigate the effect of ECCD injection on the stability, growth, and dynamical behavior of magnetic islands associated with resistive tearing modes. In addition to qualitatively and quantitatively agreeing with numerical results obtained from the inclusion of localized ECCD deposition in static equilibrium solvers [A. Pletzer and F. W. Perkins, Phys. Plasmas 6, 1589 (1999)], predictions from the model further elaborate the role which rational surface motion plays in these results. The complete suppression of the (2,1) resistive tearing mode by ECCD is demonstrated and the relevant stabilization mechanism is determined. Consequences of the shifting of the mode rational surface in response to the injected current are explored, and the characteristic short-time responses of resistive tearing modes to spatial ECCD alignments which are stabilizing are also noted. We discuss the relevance of this work to the development of more comprehensive predictive models for ECCD-based mitigation and control of neoclassical tearing modes.
Göbbels, M; Gross, D
1996-01-01
In this controlled, randomized, double-masked study the effect of dexpanthenol-containing artificial tears (Siccaprotect) on patients with dry eyes was examined. 50 patients applied either dexpanthenol-containing artificial tears (Siccaprotect) or the identical, but free of dexpanthenol, eye drops five times daily into the conjunctival sac. No other ophthalmics were administered. The corneal epithelial permeability was measured by fluorophotometry and Schirmer-Test, Rose Bengal staining, tear film break-up time and the patients' subjective complaints were determined before and after 6 weeks of treatment. The dexpanthenol-containing artificial tears (Siccaprotect) improved disturbances of the corneal epithelial permeability significantly in comparison to the dexpanthenol-free eyes drops. The other parameters didn't show relevant differences. These data suggest that, in dry eyes, treatment with dexpanthenol-containing eye drops leads to a favorable and comparing with dexpanthenol-free eye drops superior improvement in disturbances of corneal epithelium permeability.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goldberg, A.; Lesuer, D.R.; Patt, J.
In order to effectively utilize fractography as an aid in identifying the influence of material and service (or test) parameters on material properties, one must first understand the origin of the morphological features developed during the tearing and fracturing of these elastomers. At our laboratory, we have made extensive fractographic studies while evaluating the effects of material formulations, temperature, and loading rates on the loading response, tearing energy, induced damage, and tearing phenomena in SBR (Styrene Butadiene Rubber) containing different amounts of CB (Carbon Black) filler. We have also examined failures in tank track pads, as well as laboratory-tested samplesmore » cut from new track pads. In this paper we report on observations made during the actual stretching, tearing and failure of elastomeric samples pulled in tension at a constraint stroke-diplacement rate. 15 refs., 12 figs.« less
Zhu, Lei; Zhang, Cheng; Chuck, Roy S
2012-01-01
To evaluate the effect of the topical steroid, fluorometholone, and the non-steroidal anti-inflammatory drugs (NSAIDs), nepafenac and ketorolac, on inflammatory cytokine expression of the ocular surface in the botulium toxin B-induced murine dry eye model. Topical artificial tears (0.5% carboxymethylcellulose sodium), 0.1% fluorometholone, 0.1% nepafenac, and 0.4% ketorolac were applied 3 times per day in a dry eye mouse model 1 week after intralacrimal botulium toxin B (BTX-B) or saline (sham) injection. Tear production and corneal fluorescein staining were evaluated in all groups before injection at baseline and at 3 time points up to 4 weeks after injection. The pro-inflammatory cytokines interleukin-1β (IL-1β) and tumor necrosis factor-α (TNF-α) were evaluated by immunohistochemistry. BTX-B-injected mice showed significantly decreased aqueous tear production and increased corneal fluorescein staining at the 1 and 2 week time points compared with normal control and saline-injected mice. In the BTX-B-injected mice, immunofluorescent staining for TNF-α and IL-1β in corneal and conjunctival epithelial cells increased significantly at the 2 and 4 week time points compared to that of normal and saline-injected mice, and returned to normal levels at the 4 week time point. Topical fluorometholone significantly improved corneal surface staining in the BTX-B-injected mice after 1 week of treatment, and increased the tear production within 2 weeks, but without statistical significant difference. Topical fluorometholone significantly decreased the staining of TNF-α and IL-1β in corneal and conjunctival epithelia after 1-week treatment. Topical artificial tears, 0.1% nepafenac, and 0.4% ketorolac did not show obvious effects on tear production, corneal surface staining, and levels of IL-1β and TNF-α expression in normal, and BTX-B-injected dry eye mice. Topical fluorometholone caused suppression of inflammatory cytokine expression on the ocular surface in the Botulium toxin B-induced murine dry eye model, while topical NSAIDs demonstrated no clearly beneficial effects.
Repeatability of a new method for measuring tear evaporation rates.
Petznick, Andrea; Tan, Jen Hong; Boo, Shiao Khee; Lee, Sze Yee; Acharya, U Rajendra; Tong, Louis
2013-04-01
The purpose of this study was to evaluate the repeatability of tear evaporimetry based on infrared thermography in a clinical room setting and to test the effect of changing environmental humidity on ocular surface temperature (OST) and tear evaporation rates (TERs) in a controlled adverse environmental (CAE) chamber. Twenty-six healthy participants were enrolled, of whom 16 underwent repeatability measurements in a clinical room and 10 were exposed to a constant temperature of 30°C with a humidity of 45 and 65% in a CAE. Participants were acclimatized to each condition for at least 20 minutes before OSTs were taken. Tear film breakup time was assessed in the CAE only. Number of blinks and OSTs were continuously measured for 20 seconds for the cornea, conjunctiva, and overall ocular surface with an infrared camera; corresponding TERs were calculated. The OSTs and TERs showed acceptable strength of agreement between the first and second measurements. The coefficients of repeatability were 0.4°C for OST and 6.0 W m for TER. An increase in chamber humidity (from 45 to 65%) increased OST (p < 0.05). The TER was not changed significantly (p > 0.05). The tear film breakup time and number of blinks were not significantly affected by different humidity conditions. This technique has acceptable repeatability and has potential to document individual tear evaporation changes with time where humidity may differ by less than 20%.
Park, Gi-Young; Kwon, Dong Rak; Lee, Sang Chul
2015-11-01
Rotator cuff tendon tear is one of the most common causes of chronic shoulder pain and disability. In this study, we investigated the therapeutic effects of ultrasound-guided human umbilical cord blood (UCB)-derived mesenchymal stem cell (MSC) injection to regenerate a full-thickness subscapularis tendon tear in a rabbit model by evaluating the gross morphology and histology of the injected tendon and motion analysis of the rabbit's activity. At 4 weeks after ultrasound-guided UCB-derived MSC injection, 7 of the 10 full-thickness subscapularis tendon tears were only partial-thickness tears, and 3 remained full-thickness tendon tears. The tendon tear size and walking capacity at 4 weeks after UCB-derived MSC injection under ultrasound guidance were significantly improved compared with the same parameters immediately after tendon tear. UCB-derived MSC injection under ultrasound guidance without surgical repair or bioscaffold resulted in the partial healing of full-thickness rotator cuff tendon tears in a rabbit model. Histology revealed that UCB-derived MSCs induced regeneration of rotator cuff tendon tear and that the regenerated tissue was predominantly composed of type I collagens. In this study, ultrasound-guided injection of human UCB-derived MSCs contributed to regeneration of the full-thickness rotator cuff tendon tear without surgical repair. The results demonstrate the effectiveness of local injection of MSCs into the rotator cuff tendon. The results of this study suggest that ultrasound-guided umbilical cord blood-derived mesenchymal stem cell injection may be a useful conservative treatment for full-thickness rotator cuff tendon tear repair. ©AlphaMed Press.
Park, Gi-Young; Lee, Sang Chul
2015-01-01
Rotator cuff tendon tear is one of the most common causes of chronic shoulder pain and disability. In this study, we investigated the therapeutic effects of ultrasound-guided human umbilical cord blood (UCB)-derived mesenchymal stem cell (MSC) injection to regenerate a full-thickness subscapularis tendon tear in a rabbit model by evaluating the gross morphology and histology of the injected tendon and motion analysis of the rabbit’s activity. At 4 weeks after ultrasound-guided UCB-derived MSC injection, 7 of the 10 full-thickness subscapularis tendon tears were only partial-thickness tears, and 3 remained full-thickness tendon tears. The tendon tear size and walking capacity at 4 weeks after UCB-derived MSC injection under ultrasound guidance were significantly improved compared with the same parameters immediately after tendon tear. UCB-derived MSC injection under ultrasound guidance without surgical repair or bioscaffold resulted in the partial healing of full-thickness rotator cuff tendon tears in a rabbit model. Histology revealed that UCB-derived MSCs induced regeneration of rotator cuff tendon tear and that the regenerated tissue was predominantly composed of type I collagens. In this study, ultrasound-guided injection of human UCB-derived MSCs contributed to regeneration of the full-thickness rotator cuff tendon tear without surgical repair. The results demonstrate the effectiveness of local injection of MSCs into the rotator cuff tendon. Significance The results of this study suggest that ultrasound-guided umbilical cord blood-derived mesenchymal stem cell injection may be a useful conservative treatment for full-thickness rotator cuff tendon tear repair. PMID:26371340
Milner, Mark S; Beckman, Kenneth A; Luchs, Jodi I; Allen, Quentin B; Awdeh, Richard M; Berdahl, John; Boland, Thomas S; Buznego, Carlos; Gira, Joseph P; Goldberg, Damien F; Goldman, David; Goyal, Raj K; Jackson, Mitchell A; Katz, James; Kim, Terry; Majmudar, Parag A; Malhotra, Ranjan P; McDonald, Marguerite B; Rajpal, Rajesh K; Raviv, Tal; Rowen, Sheri; Shamie, Neda; Solomon, Jonathan D; Stonecipher, Karl; Tauber, Shachar; Trattler, William; Walter, Keith A; Waring, George O; Weinstock, Robert J; Wiley, William F; Yeu, Elizabeth
2017-01-01
Dysfunctional tear syndrome (DTS) is a common and complex condition affecting the ocular surface. The health and normal functioning of the ocular surface is dependent on a stable and sufficient tear film. Clinician awareness of conditions affecting the ocular surface has increased in recent years because of expanded research and the publication of diagnosis and treatment guidelines pertaining to disorders resulting in DTS, including the Delphi panel treatment recommendations for DTS (2006), the International Dry Eye Workshop (DEWS) (2007), the Meibomian Gland Dysfunction (MGD) Workshop (2011), and the updated Preferred Practice Pattern guidelines from the American Academy of Ophthalmology pertaining to dry eye and blepharitis (2013). Since the publication of the existing guidelines, new diagnostic techniques and treatment options that provide an opportunity for better management of patients have become available. Clinicians are now able to access a wealth of information that can help them obtain a differential diagnosis and treatment approach for patients presenting with DTS. This review provides a practical and directed approach to the diagnosis and treatment of patients with DTS, emphasizing treatment that is tailored to the specific disease subtype as well as the severity of the condition.
Milner, Mark S.; Beckman, Kenneth A.; Luchs, Jodi I.; Allen, Quentin B.; Awdeh, Richard M.; Berdahl, John; Boland, Thomas S.; Buznego, Carlos; Gira, Joseph P.; Goldberg, Damien F.; Goldman, David; Goyal, Raj K.; Jackson, Mitchell A.; Katz, James; Kim, Terry; Majmudar, Parag A.; Malhotra, Ranjan P.; McDonald, Marguerite B.; Rajpal, Rajesh K.; Raviv, Tal; Rowen, Sheri; Shamie, Neda; Solomon, Jonathan D.; Stonecipher, Karl; Tauber, Shachar; Trattler, William; Walter, Keith A.; Waring, George O.; Weinstock, Robert J.; Wiley, William F.; Yeu, Elizabeth
2017-01-01
Dysfunctional tear syndrome (DTS) is a common and complex condition affecting the ocular surface. The health and normal functioning of the ocular surface is dependent on a stable and sufficient tear film. Clinician awareness of conditions affecting the ocular surface has increased in recent years because of expanded research and the publication of diagnosis and treatment guidelines pertaining to disorders resulting in DTS, including the Delphi panel treatment recommendations for DTS (2006), the International Dry Eye Workshop (DEWS) (2007), the Meibomian Gland Dysfunction (MGD) Workshop (2011), and the updated Preferred Practice Pattern guidelines from the American Academy of Ophthalmology pertaining to dry eye and blepharitis (2013). Since the publication of the existing guidelines, new diagnostic techniques and treatment options that provide an opportunity for better management of patients have become available. Clinicians are now able to access a wealth of information that can help them obtain a differential diagnosis and treatment approach for patients presenting with DTS. This review provides a practical and directed approach to the diagnosis and treatment of patients with DTS, emphasizing treatment that is tailored to the specific disease subtype as well as the severity of the condition. PMID:28099212
Efficacy of topical nerve growth factor treatment in dogs affected by dry eye.
Coassin, Marco; Lambiase, Alessandro; Costa, Nicola; De Gregorio, Alessandra; Sgrulletta, Roberto; Sacchetti, Marta; Aloe, Luigi; Bonini, Stefano
2005-02-01
Preliminary data show that nerve growth factor (NGF) may improve tear production in humans. We evaluated the efficacy of topical NGF treatment in dogs who developed dry eye after the excision of the third eyelid lacrimal gland. English Bulldogs (2- to 6-year-old males and females) that had undergone the surgical removal of the prolapsed lacrimal gland of the third eyelid in both eyes at the age of 3-6 months developed chronic keratoconjunctivitis sicca associated with a decrease of Schirmer tear test I values after at least 1 year. One eye, randomly selected, of each dog was treated twice daily with 100 microl of NGF ointment for 1 month, while the fellow eye was used as control and treated with the ointment vehicle only. At baseline and after 1 month of NGF treatment the following examinations were performed: corneal evaluation by slit lamp, fluorescein staining, Schirmer tear test I, tear ferning test, corneal esthesiometry by cotton swab and conjunctival impression cytology. Topical application of NGF caused a significant improvement of all the evaluated parameters compared with baseline values. In contrast, in the control eyes there was no significant difference between the values measured before and after treatment. In particular, after NGF treatment superficial punctate keratopathy was resolved, corneal haze was reduced from stage 4 to stage 2 and Schirmer test values increased (17.2+/-1.7 mm/min vs 4.5+/-1.3 mm/min; p<0.05), as did the tear mucous component (as demonstrated by ferning test: 2.0+/-0.0 vs 4.0+/-0.0; p<0.05); conjunctival impression cytology evaluation demonstrated the presence of numerous mucous filaments and a significant increase in conjunctival goblet cell density (102.7+/-68.3 vs. 18.2+/-14.3 cell x field; p<0.05). Topical NGF treatment improved corneal sensitivity in two of three eyes. This open study suggests that topical application of NGF may enhance the production and functional characteristics in tear film, with an improvement of ocular surface signs in dogs with surgically induced dry eye. These results suggest the possibility of performing further, larger, controlled studies.
Koh, Shizuka; Ikeda, Chikako; Fujimoto, Hisataka; Oie, Yoshinori; Soma, Takeshi; Maeda, Naoyuki; Nishida, Kohji
2016-07-01
To noninvasively investigate regional differences in tear film stability and meibomian glands in patients with aqueous-deficient dry eye. Forty-nine dry eyes and 31 normal eyes were analyzed. A corneal topographer with a tear film scanning function was used for noninvasive tear film break-up time (NI-TFBUT) measurements and meibomian gland observations. The NI-TFBUT values and location of the first tear film break-up point were recorded in four quadrants. Meibomian gland loss was graded for each eyelid using meiboscores. Lid margin abnormality was scored from zero to four according to the number of existing abnormalities. The NI-TFBUT values and meiboscores were compared between two groups, and regional differences in NI-TFBUT values and meiboscores were analyzed. Also, the correlation between the NI-TFBUT and ocular surface examination results were investigated. The NI-TFBUT values and meiboscores were significantly lower and higher, respectively, for the dry eye group than for the normal group. In the dry eye group, the occurrence rate for first tear film break-up was the highest in the inferior nasal quadrant, and the mean meiboscore was significantly higher for the upper eyelids than for the lower eyelids. The NI-TFBUT and lid margin abnormality scores showed a weak negative correlation, and the NI-TFBUT values and meiboscores showed no correlation. Compared to normal eyes, aqueous-deficient dry eyes show significant regional differences in tear film stability and meibomian glands. Considering these regional differences, the overall observation of the ocular surface, including both upper and lower eyelids, will aid clinicians in understanding this condition better.
Current profile redistribution driven by neutral beam injection in a reversed-field pinch
NASA Astrophysics Data System (ADS)
Parke, E.; Anderson, J. K.; Brower, D. L.; Den Hartog, D. J.; Ding, W. X.; Johnson, C. A.; Lin, L.
2016-05-01
Neutral beam injection in reversed-field pinch (RFP) plasmas on the Madison Symmetric Torus [Dexter et al., Fusion Sci. Technol. 19, 131 (1991)] drives current redistribution with increased on-axis current density but negligible net current drive. Internal fluctuations correlated with tearing modes are observed on multiple diagnostics; the behavior of tearing mode correlated structures is consistent with flattening of the safety factor profile. The first application of a parametrized model for island flattening to temperature fluctuations in an RFP allows inferrence of rational surface locations for multiple tearing modes. The m = 1, n = 6 mode is observed to shift inward by 1.1 ± 0.6 cm with neutral beam injection. Tearing mode rational surface measurements provide a strong constraint for equilibrium reconstruction, with an estimated reduction of q0 by 5% and an increase in on-axis current density of 8% ± 5%. The inferred on-axis current drive is consistent with estimates of fast ion density using TRANSP [Goldston et al., J. Comput. Phys. 43, 61 (1981)].
Tear Film Dynamics: the roles of complex structure and rheology
NASA Astrophysics Data System (ADS)
Dey, Mohar; Feng, James; Vivek, Atul S.; Dixit, Harish N.; Richhariya, Ashutosh
2016-11-01
Ocular surface infections such as microbial and fungal keratitis are among leading causes of blindness in the world. A thorough understanding of the pre-corneal tear film dynamics is essential to comprehend the role of various tear layer components in the escalation of such ocular infections. The pre-corneal tear film comprises of three layers of complex fluids, viz. the innermost mucin layer, a hydrophilic protective cover over the sensitive corneal epithelium, the intermediate aqueous layer that forms the bulk of the tear film and is often embedded with large number of bio-polymers either in the form of soluble mucins or pathogens, and finally the outermost lipid layer that stabilizes the film by decreasing the air/tear film interfacial tension. We have developed a comprehensive mathematical model to describe such a film by incorporating the effects of the non-uniform mucin distribution along with the complex rheology of the aqueous layer with/without pathogens, Marangoni effects from the lipid layer and the slip effects at the base of the tear film. A detailed linear stability analysis and a fully non-linear solution determine the break up time (BUT) of such a tear film. We also probe the role of the various components of the pre-corneal tear film in the dynamics of rupture.
The effect of mimosa and syntan mixture on the quality of tanned red snapper leather
NASA Astrophysics Data System (ADS)
Pratama, M.; Sahubawa, L.; Pertiwiningrum, A.; Rahmadian, Y.; Puspita, I. D.
2018-03-01
This study aimed to determine the effect of syntan and mimosa combination on the quality of tanned red snapper leather. The study was designed using complete randomized design (CRD) and the advanced test of Least Significant Difference (LSD) with three replications and three treatments of combined syntan and mimosa, namely: p1 (4 % syntan, 5 % mimosa), p2 (8 % syntan, 5 %mimosa), p3 (12 % syntan, 5 % mimosa). Data were analyzed using SPSS 18. The measured parameters were tensile strength (N·cm-2), elongation (%), tear strength (N·cm-1), enervation (mm), wrinkle temperature (°C), fat/oil content (%) and water content (%). The results indicate that the combined syntan and mimosa tanners gave no significant effect on the physical parameters (tensile strength, elongation, tear strength, enervation and wrinkle temperature) and chemical parameters (moisture and fat/oil). All treatments (p1, p2 and p3) met the Indonesian National Standard (SNI) 06-4586-1998 for chrome tanned freshwater snake leather for the parameters of tensile strength, tear strength, enervation, wrinkle temperature and moisture. The parameter of elongation and fat/oil content did not meet with the SNI 06-4586-1998. Among the three combinations of a tanner, syntan 4 % and mimosa 5 % treatment gave the best leather quality.
[A study on the diagnostic value of tear film objective scatter index in dry eye].
Su, Y D; Liang, Q F; Wang, N L; Antoine, Labbè
2017-09-11
Objective: To study the sensitivity and specificity of tear film objective scatter index to the diagnosis dry eye disease (DED). Methods: A prospective case-controlled study. Fifty-three patients with DED and 32 healthy age- and sex-matched control subjects were included from July to October 2016. All subjects underwent the examinations sequentially as follows: evaluation of ocular surface disease symptoms using the Ocular Surface Disease Index, optical quality detection, lipid layer thickness, tear film breakup time and SchirmerⅠtest. With Optical Quality Analysis SystemⅡ, the values of modulation transfer function cut off, basic objective scatter index (OSI) and total OSI were measured. To eliminate the influence of other refractive media, the tear film OSI (TF-OSI) was calculated, and the difference in TF-OSI between two groups was analyzed with the independent-samples t test. Spearman's correlation analysis was used to detect the correlation of each parameter in the DED group. With the receiver operating characteristic curve and the area under the curve (AUC), the specificity and sensitivity of TF-OSI and other parameters were described to differentiate DED from normal eyes. Results: In the dry eye group, the value of modulation transfer function cut off (32.07±11.95) was significantly lower than the normal group (39.38±9.44, t=- 3.096, P= 0.003) , and the mean value and dispersion of TF-OSI (0.50±0.43, 0.52±0.81) were higher than the normal group (0.21±0.16, 0.12±0.01) ( t= 4.300, P= 0.000, t= 3.546, P= 0.001) . The mean value of TF-OSI had a positive correlation with lipid layer thickness ( r= 0.365, P= 0.007) and dispersion of TF-OSI ( r= 0.581, P= 0.000), and a negative correlation with MTF cut off ( r=- 0.368, P= 0.007). To the diagnostic value of DED, the mean value of TF-OSI had a sensitivity of 0.736, a specificity of 0.762, and the AUC was 0.764. The dispersion of TF-OSI had a sensitivity of 0.811 and a specificity of 0.810, and the AUC was 0.900. Conclusion: In the DED group, the mean value and dispersion of TF-OSI were higher than the normal group. With its advantages, the TF-OSI may be a new method for the auxiliary diagnosis of dry eye. (Chin J Ophthalmol, 2017, 53: 668-674) .
An Overview on Dry Eye Treatment: Approaches for Cyclosporin A Delivery
Yavuz, Burçin; Bozdağ Pehlivan, Sibel; Ünlü, Nurşen
2012-01-01
Dry eye syndrome (DES, Keratoconjunctivitis sicca) is a common disorder of the tear film caused by decreased tear production or increased evaporation. Changes in tear composition also promote inflammation on the ocular surface by various mechanisms. Artificial tear drops, tear retention treatment, stimulation of tear secretion, or anti-inflammatory drugs may be used for dry eye treatment according to the severity of the disease. For untreated patients, the risk of ocular infection increases at considerable level and clinical course of the disease may proceed up to infection, corneal ulcer, and blindness. Artificial tears and/or punctual occlusions are used for tear replacement or preservation. New treatment approaches are designed to modify the underlying disease process. For the treatment of severe dry eye disease, cyclosporin A (CsA), the first one of the new generation immunomodulatory drugs, which has an anti-inflammatory effect, is frequently used. CsA has immunosuppressive effects following systemic application. Following local administration of CsA, it is expected to obtain effective drug concentration at the target area and to avoid the various side effects associated with systemic delivery. Microspheres, implants, and liposomes have been developed for administration of CsA subconjunctivally in order to enhance its efficiency. PMID:22619624
Yamada, Kentaro; Henares, Terence G; Suzuki, Koji; Citterio, Daniel
2015-11-11
"Distance-based" detection motifs on microfluidic paper-based analytical devices (μPADs) allow quantitative analysis without using signal readout instruments in a similar manner to classical analogue thermometers. To realize a cost-effective and calibration-free distance-based assay of lactoferrin in human tear fluid on a μPAD not relying on antibodies or enzymes, we investigated the fluidic mobilities of the target protein and Tb(3+) cations used as the fluorescent detection reagent on surface-modified cellulosic filter papers. Chromatographic elution experiments in a tear-like sample matrix containing electrolytes and proteins revealed a collapse of attractive electrostatic interactions between lactoferrin or Tb(3+) and the cellulosic substrate, which was overcome by the modification of the paper surface with the sulfated polysaccharide ι-carrageenan. The resulting μPAD based on the fluorescence emission distance successfully analyzed 0-4 mg mL(-1) of lactoferrin in complex human tear matrix with a lower limit of detection of 0.1 mg mL(-1) by simple visual inspection. Assay results of 18 human tear samples including ocular disease patients and healthy volunteers showed good correlation to the reference ELISA method with a slope of 0.997 and a regression coefficient of 0.948. The distance-based quantitative signal and the good batch-to-batch fabrication reproducibility relying on printing methods enable quantitative analysis by simply reading out "concentration scale marks" printed on the μPAD without performing any calibration and using any signal readout instrument.
Subregional effects of meniscal tears on cartilage loss over 2 years in knee osteoarthritis.
Chang, Alison; Moisio, Kirsten; Chmiel, Joan S; Eckstein, Felix; Guermazi, Ali; Almagor, Orit; Cahue, September; Wirth, Wolfgang; Prasad, Pottumarthi; Sharma, Leena
2011-01-01
Meniscal tears have been linked to knee osteoarthritis progression, presumably by impaired load attenuation. How meniscal tears affect osteoarthritis is unclear; subregional examination may help to elucidate whether the impact is local. This study examined the association between a tear within a specific meniscal segment and subsequent 2-year cartilage loss in subregions that the torn segment overlies. Participants with knee osteoarthritis underwent bilateral knee MRI at baseline and 2 years. Mean cartilage thickness within each subregion was quantified. Logistic regression with generalised estimating equations were used to analyse the relationship between baseline meniscal tear in each segment and baseline to 2-year cartilage loss in each subregion, adjusting for age, gender, body mass index, tear in the other two segments and extrusion. 261 knees were studied in 159 individuals. Medial meniscal body tear was associated with cartilage loss in external subregions and in central and anterior tibial subregions, and posterior horn tear specifically with posterior tibial subregion loss; these relationships were independent of tears in the other segments and persisted in tibial subregions after adjustment for extrusion. Lateral meniscal body and posterior horn tear were also associated with cartilage loss in underlying subregions but not after adjustment for extrusion. Cartilage loss in the internal subregions, not covered by the menisci, was not associated with meniscal tear in any segment. These results suggest that the detrimental effect of meniscal tears is not spatially uniform across the tibial and femoral cartilage surfaces and that some of the effect is experienced locally.
Efficacy of Rebamipide Instillation for Contact Lens Discomfort With Dry Eye.
Igarashi, Tsutomu; Kobayashi, Maika; Yaguchi, Chiemi; Fujimoto, Chiaki; Suzuki, Hisaharu; Takahashi, Hiroshi
2017-11-10
To examine the effects of rebamipide ophthalmic solution on the symptoms, signs, and cytokine concentrations in tear fluid among soft contact lens (SCL) wearers with Dry eye disease (DED). From November 2015 to June 2017, this open-label, single-arm study examined 40 eyes of 20 SCL wearers with DED who had been using daily disposable SCLs for >3 months (mean age, 30.0±8.33 years; range, 20-47 years). Signs, symptoms, and cytokine concentrations were assessed before and 4 weeks after starting 2% rebamipide ophthalmic solution 4 times/day. Dry eye disease was diagnosed according to: compromised tear dynamics (Schirmer test ≤5 mm or tear break-up time (TBUT) ≤5 sec); ocular surface abnormalities (positive vital staining with fluorescein or lissamine green); and presence of symptoms. Touch thresholds using a Cochet-Bonnet anesthesiometer were also determined for the cornea and conjunctivae. Symptoms were assessed using the 12-item Ocular Surface Disease Index questionnaire. Concentrations of cytokines in tear fluid were measured. Significant improvements in signs were seen for TBUT, surface abnormalities, and touch thresholds. Ocular Surface Disease Index scores likewise improved significantly in all the 12 items. Of the cytokines measured, only interleukin-1β, interleukin-8, and monocyte chemotactic protein-1 were found in ≥60% of tear samples, with no significant differences in concentrations before and after rebamipide use. Rebamipide significantly improved all signs and symptoms in patients with DED who wore daily disposable SCLs. Rebamipide is effective for DED treatment with SCL wear.This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Georgakopoulos, Constantine D; Makri, Olga E; Pagoulatos, Dionisios; Vasilakis, Panagiotis; Peristeropoulou, Politimi; Kouli, Vasiliki; Eliopoulou, Maria I; Psachoulia, Caterina
2017-01-01
The objective of this study was to investigate the effect of dietary supplementation with omega-3 fatty acids on ocular surface and tear film in patients with type 2 diabetes suffering from dry eye. Thirty-six patients suffering from type 2 diabetes and moderate to severe dry eye syndrome were included in the study. Patients were assigned to receive omega-3 long-chain polyunsaturated fatty acids for 3 months. Tear film break-up time test, Schirmer-I test, and conjunctival impression cytology analysis were performed on all patients at baseline and after 1 and 3 months. The subjective symptoms of dry eye were evaluated with the Ocular Surface Disease Index (OSDI) questionnaire at the same time points. Patients' average age was 65.57 ± 4.27 years and the mean duration of diabetes was 14.85 ± 5.4 years. There was a statistically significant increase in Schirmer-I test results and tear break-up time score after 3 months of supplementary intake of omega-3 fatty acids compared to baseline (p < 0.05 and p < 0.001, respectively). Impression cytology demonstrated a significantly lower grade of conjunctival squamous cell metaplasia after 1 and 3 months of omega-3 fatty acids intake compared to baseline (p < 0.05 and p < 0.01, respectively). The OSDI score was statistically significant lower both at 1 and 3 months after omega-3 fatty acids supplementation compared to baseline (p < 0.001). Omega-3 fatty acids may effectively improve tear film characteristics, reverse ocular surface features, and alleviate the subjective symptoms associated with dry eye syndrome in patients with type 2 diabetes.
Impact of wildfire smoke in Buenos Aires, Argentina, on ocular surface.
Berra, Martin; Galperín, Gustavo; Dawidowski, Laura; Tau, Julia; Márquez, Isabel; Berra, Alejandro
2015-01-01
To evaluate the acute impact of the wildfire smoke episode in 2008 on the ocular surface of subjects living in the Metropolitan Area of Buenos Aires (MABA). A total of 86 subjects were evaluated: Group 1 comprised patients from a public ophthalmology hospital (N=35) and Group 2 comprised healthy volunteers (N=51). All subjects answered a questionnaire on ocular symptoms and underwent ophthalmologic examination [bulbar conjunctival hyperemia, corneal fluorescein staining, rose bengal vital staining, tear break-up time (TBUT), Schirmer I test, tear lysozyme, and impression cytology] during and after the acute episode. Concentrations of carbon monoxide (CO), nitrogen dioxide (NO2), and particulate matter (PM) were measured before, during, and after the acute episode. Both groups showed a statically significant increase in ocular symptoms and bulbar conjunctival hyperemia and a statically significant decrease in tear break-up time during the acute episode. Group 1 showed more severe symptoms and a statistically significant increase in fluorescein and rose bengal staining intensities during the acute episode. We found a significant negative correlation between ocular symptoms and tear break-up time. During the episode, the levels of CO, NO2, and particulate matter in MABA were four times higher than the usual average levels for the same period in 2007 and 2009. Increased air pollution from the burning of biomass is associated with a decrease in the stability of the tear film (TBUT), generating areas of ocular surface exposure that may be the cause of the increased feeling of irritation. Group 1 was more affected by not having a healthy ocular surface, and thus consulted an ophthalmologist. Cytological changes in the conjunctiva were not observed, which could be due to the short duration of the episode.
Bartlett, Jimmy D; Holland, Edward J; Usner, Dale W; Paterno, Michael R; Comstock, Timothy L
2008-08-01
To compare the ocular comfort and tolerability of loteprednol etabonate 0.5%/tobramycin 0.3% (LE/T; Zylet) with dexamethasone 0.1%/tobramycin 0.3% (DM/T; TobraDex) in healthy volunteers. In this multicenter, randomized, double-masked, parallel-group study, healthy volunteers (n = 306) were randomized to receive LE/T or DM/T four times per day for 28 days. Subjects recorded subjective ratings for seven comfort/tolerability parameters using an electronic patient diary (EPD). The primary endpoint was the difference at week 4 from the ratings of an artificial tear at baseline in comfort/tolerability parameters between treatment groups, using a noninferiority paradigm. ClinicalTrials. gov, NCT 00532961. The 97.5% confidence intervals for the lower bound were within -10 for all of the seven comfort/ tolerability parameters evaluated (pain, stinging/burning, irritation, itchiness, foreign-body sensation, dryness, and light sensitivity). Secondary analysis revealed small but significant within-treatment differences in pain favoring LE/T over tears and in light sensitivity favoring tears over DM/T (p < 0.01). Small between-treatment differences in the changes from baseline tear ratings to individual study visits favored LE/T for pain, stinging/burning, irritation, itchiness, foreign-body sensation, and light sensitivity at visit 4 (p < or = 0.04); for pain, stinging/burning, and foreignbody sensation at visit 5 (p < or = 0.03), and for dryness and light sensitivity at visit 6 (p < or = 0.05). LE/T satisfied all conditions of noninferiority to DM/T in comfort and tolerability. Subjects receiving LE/T were more likely to report better ocular comfort/tolerability ratings relative to baseline artificial tears than subjects receiving DM/T. The study population consisted of healthy volunteers.
The effects of Ramadan fasting on the health and function of the eye
Javadi, Mohammad Ali; Assadi, Mahsan; Einollahi, Bahram; Rabei, Hossein Mohammad; Afarid, Mehrdad; Assadi, Majid
2014-01-01
Background: Ramadan fasting may alter a variety of physiological parameters which by themselves influence ocular system. Here, we review the effects of Ramadan fasting on the health and function of the eye. Materials and Methods: Literature records in PubMed/MEDLINE, Web of Science, EMBASE, Google Scholar, and Iran Medex databases as well as proceedings of related meetings from January 1986 to March 2014 were systematically reviewed. The search key words was based on the terms “Ramadan Fasting,” “Ramadan,” “Islamic Fasting,” “Fasting in Ramadan” accompanied with one of the eye, tear drop, myopia, intraocular pressure (IOP), tear break up time, basal tear secretion, refractive error, and visual acuity. Results: Predawn water loading and dehydration in the evening are shown to increase and decrease IOP and tear secretion, respectively. Ocular blood flow is changed in Ramadan fasting, and patients with ocular vein occlusion may experience more frequent attacks. There are no or minimal fluctuations in visual acuity and refractive errors, but most of them are decompensated after Ramadan. Conclusion: Although the influence of fasting in different eye parameters is evaluated in several studies, there are no or only limited studies conducted on patients suffering from glaucoma, damage to ophthalmic vasculature, tear dysfunction, and minimal visual acuity. Such studies are required to make a definite decision before fasting is declared harmless to these patients. PMID:25422666
Nonlinear saturation of tearing mode islands.
Hastie, R J; Militello, F; Porcelli, F
2005-08-05
New, rigorous results for the tearing island saturation problem are presented. These results are valid for the realistic case where the magnetic island structure is non-symmetric about the reconnection surface and the electron temperature, on which the electrical resistivity depends, is evolved self-consistently with the island growth.
Evaluating tear clearance rate with optical coherence tomography.
Garaszczuk, Izabela K; Mousavi, Maryam; Cervino Exposito, Alejandro; Bartuzel, Maciej M; Montes-Micó, Robert; Iskander, D Robert
2018-02-01
To assess the early-phase of tear clearance rate (TCR) with anterior segment optical coherence tomography (OCT) and to determine the association between TCR and other clinical measures of the tear film in a group of young subjects with different levels of tear film quality. TCR was classified as the percentage decrease of subject's inferior tear meniscus height 30s after instillation of 5μl 0.9% saline solution. Fifty subjects (32F and 18M) aged (mean±standard deviation) 25.5±4.3 years volunteered for the study. It consisted of a review of medical history, Ocular Surface Disease Index (OSDI) questionnaire, tear film osmolarity measurements, slit lamp examination and TCR estimation based on dynamic measurements of the lower tear meniscus with OCT. Estimates of TCR were contrasted against subject age and tear film measures commonly used for dry eye diagnosis, which includes OSDI score, fluorescein tear film break-up time (FBUT), tear meniscus height (TMH), blinking frequency, tear film osmolarity and corneal staining. The group mean TCR was 29±13% and 36±19% respectively after 30 and 60s margin after saline solution instillation. Statistically significant correlations were found between TCR and FBUT (r 2 =0.319, p<0.001), blinking frequency (r 2 =0.138, p<0.01), tear film osmolarity (r 2 =0.133, p<0.01) and subject's age (r 2 =0.095, p<0.05). Anterior segment optical coherence tomography allows following changes of tear meniscus morphology post saline solution instillation and evaluating the TCR. OCT based TCR might be used as additional measure of the lacrimal functional unit. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
[Neuronal and hormonal regulatory mechanisms of tears production and secretion].
Mrugacz, Małgorzata; Zywalewska, Nella; Bakunowicz-Lazarczyk, Alina
2005-01-01
The ocular surface, tear film, lacrimal glands act as a functional unit to preserve the quality of the refractive surface of the eye, and to resist injury and protect the eye against bodily and environmental conditions. Homeostasis of this functional unit involves neuronal and hormonal regulatory mechanisms. The eye appears to be a target organ for sex hormones particulary the androgen, as they modulate the immune system and trophic functions of the lacrimal and Meibomian glands.
Massie, Isobel; Dietrich, Jana; Roth, Mathias; Geerling, Gerd; Mertsch, Sonja; Schrader, Stefan
2016-10-01
The lacrimal gland is located in the upper temporal compartment of the orbita, and along with the ocular surface, eye lids, and sensory and motor nerves forms the lacrimal functional unit (LFU). The LFU is responsible for producing, distributing, and maintaining the tear film in order to maintain a smooth, moist, and regular ocular surface epithelium such that appropriate refractive properties are achieved and the eyeball is protected against dust, debris, and pathogens. If the main lacrimal gland is impaired (due to either disease or injury), this balance is disrupted, and severe quantitative dry eye syndrome (DES) can develop. DES treatments remain palliative, with the most commonly used therapies being based on tear substitution, tear retention, and control of inflammation on the ocular surface. Causative treatments such as salivary gland transplantation have shown to reduce symptoms in very severe cases, however can cause problems on the ocular surface due to different properties of saliva and tears. Therefore, causative approaches for treating DES by regeneration or reconstruction of lacrimal gland tissue depending on disease severity seem highly appealing. This article reviews current approaches for in vitro reconstruction of lacrimal gland tissue. Finally, the limitations that must be overcome before a new, tissue-engineered therapy may be delivered to clinic will be discussed.
Ru, Yusha; Huang, Yue; Liu, Huijuan; Du, Juan; Meng, Zhu; Dou, Zexia; Liu, Xun; Wei, Rui Hua; Zhang, Yan; Zhao, Shaozhen
2015-12-21
Dry eye is a highly prevalent, chronic, and multifactorial disease that compromises quality of life and generates socioeconomic burdens. The pathogenic factors of dry eye disease (DED) include tear secretion abnormalities, tear film instability, and ocular surface inflammation. An effective intervention targeting the pathogenic factors is needed to control this disease. Here we applied α-Melanocyte-stimulating hormone (α-MSH) twice a day to the ocular surface of a scopolamine-induced dry eye rat model. The results showed that α-MSH at different doses ameliorated tear secretion, tear film stability, and corneal integrity, and corrected overexpression of proinflammatory factors, TNF-α, IL-1β, and IFN-γ, in ocular surface of the dry eye rats. Moreover, α-MSH, at 10(-4) μg/μl, maintained corneal morphology, inhibited apoptosis, and restored the number and size of conjunctival goblet cells in the dry eye rats. Mechanistically, α-MSH activated both PKA-CREB and MEK-Erk pathways in the dry eye corneas and conjunctivas; pharmacological blockade of either pathway abolished α-MSH's protective effects, suggesting that both pathways are necessary for α-MSH's protection under dry eye condition. The peliotropic protective functions and explicit signaling mechanism of α-MSH warrant translation of the α-MSH-containing eye drop into a novel and effective intervention to DED.
Ru, Yusha; Huang, Yue; Liu, Huijuan; Du, Juan; Meng, Zhu; Dou, Zexia; Liu, Xun; Wei, Rui Hua; Zhang, Yan; Zhao, Shaozhen
2015-01-01
Dry eye is a highly prevalent, chronic, and multifactorial disease that compromises quality of life and generates socioeconomic burdens. The pathogenic factors of dry eye disease (DED) include tear secretion abnormalities, tear film instability, and ocular surface inflammation. An effective intervention targeting the pathogenic factors is needed to control this disease. Here we applied α-Melanocyte-stimulating hormone (α-MSH) twice a day to the ocular surface of a scopolamine-induced dry eye rat model. The results showed that α-MSH at different doses ameliorated tear secretion, tear film stability, and corneal integrity, and corrected overexpression of proinflammatory factors, TNF-α, IL-1β, and IFN-γ, in ocular surface of the dry eye rats. Moreover, α-MSH, at 10−4 μg/μl, maintained corneal morphology, inhibited apoptosis, and restored the number and size of conjunctival goblet cells in the dry eye rats. Mechanistically, α-MSH activated both PKA-CREB and MEK-Erk pathways in the dry eye corneas and conjunctivas; pharmacological blockade of either pathway abolished α-MSH’s protective effects, suggesting that both pathways are necessary for α-MSH’s protection under dry eye condition. The peliotropic protective functions and explicit signaling mechanism of α-MSH warrant translation of the α-MSH-containing eye drop into a novel and effective intervention to DED. PMID:26685899
Antioxidant content and ultraviolet absorption characteristics of human tears.
Choy, Camus Kar Man; Cho, Pauline; Benzie, Iris F F
2011-04-01
Dry eye syndrome is a common age-related disorder, and decreased antioxidant/ultraviolet (UV) radiation protection in tears may be part of the cause. This study aimed to compare the tear antioxidant content and flow rate in young and older adults. The total antioxidant content and UV absorbing properties of various commercially available ophthalmic solutions used to alleviate dry eye symptoms were also examined. Minimally stimulated tears were collected from 120 healthy Chinese adults with no ocular pathology. Two age groups were studied: 19 to 29 years (n = 58) and 50 to 75 years (n = 62). Tear samples from each subject and 13 ophthalmic solutions were analyzed for total antioxidant content (as the Ferric Reducing/Antioxidant Power value). Tear flow rates were estimated from time taken to collect a fixed volume of tear fluid. UV absorbance spectra of pooled fresh reflex tear fluid and the ophthalmic solutions were determined. Results showed that the antioxidant content of minimally stimulated tears from older subjects (398 ± 160 μmol/l) was not significantly lower than that of younger subjects (348 ± 159 μmol/l; p = 0.0915). However, there was a significant difference in the tear flow rates between the two groups (p < 0.0001), with the younger group having three to four fold higher flow rate. None of the commercial preparations tested had detectable antioxidant content, and none showed the UV absorption characteristics of natural reflex tears. The effect of low flow rate on the dynamic antioxidant supply to the corneal surface indicates that older subjects have poorer overall defense against photooxidative and other oxidative processes. This could predispose older persons to corneal stress and development of dry eye syndrome. The commercially available artificial tears tested lack both the antioxidant content and UV absorbing characteristics of natural tears. Artificial tears formulations that help restore natural antioxidant and UV absorbing properties to the tear film of the aging eye may help prevent or improve dry eye symptoms and promote ocular health.
Evaluation of lipid oxidative stress status and inflammation in atopic ocular surface disease
Wakamatsu, Tais H.; Ayako, Igarashi; Takano, Yoji; Matsumoto, Yukihiro; Ibrahim, Osama M.A.; Okada, Naoko; Satake, Yoshiyuki; Fukagawa, Kazumi; Shimazaki, Jun; Tsubota, Kazuo; Fujishima, Hiroshi
2010-01-01
Background Although the oxidative stress status in atopic skin disease has been reported to be elevated, there are still no studies related to the status of oxidative stress in atopic ocular surface disease. The purpose of this study was to evaluate the ocular surface lipid oxidative stress status and inflammation in atopic keratoconjunctivitis (AKC) patients and normal subjects. Methods Twenty eight eyes of 14 patients (9 males, 5 females) with AKC and 18 eyes of 9 age and sex matched (4 males and 5 females) normal healthy controls were examined in this prospective study. The severity of atopic dermatitis (AD) was scored by the SCORing Atopic Dermatitis (SCORAD) index. All subjects underwent Schirmer test, tear film break up time (BUT), fluorescein/Rose Bengal stainings, tear collection, and brush cytology from the upper palpebral conjunctiva. The brush cytology samples were stained with Diff-Quik for differentiation of inflammatory cells and immunohistochemistry (IHC) staining with HEL (hexanoyl-lysine) and 4-HNE (4-hydroxy-2-nonenal) to study lipid oxidation. HEL and cytokine (interleukin-4 (IL-4), interleukin-5 (IL-5), interleukin-10 (IL-10), tumor necrosis factor-alpha (TNF-α), interferon-gamma (IFN-γ)) levels were measured by enzyme-linked immunosorbent assay (ELISA) from tear samples of AKC patients and control subjects. Toluidine Blue and IHC staining with HEL, 4-HNE and cluster of differentiation 45 (CD45) were performed on papillary samples of AKC patients. This study was conducted in compliance with the “Declaration of Helsinki.” Results The tear stability and vital staining scores were significantly worse in eyes of AKC patients (p<0.05) compared to the controls. Inflammatory cells and positively stained conjunctival epithelial cells for HEL and 4-HNE showed a significant elevation in brush cytology samples of AKC patients. Significantly higher levels of HEL and cytokines were detected in tears of AKC patients compared to controls. Papillary specimens also revealed many CD45 inflammatory cells as well as many cells positively stained with HEL and 4-HNE in IHC. A strong significant linear positive correlation between conjunctival inflammation and epithelial lipid oxidative stress status was observed. Conjunctival lipid oxidative stress also correlated strongly with tear HEL levels and epithelial damage scores. Conclusions The ocular surface disease in AKC was characterized by marked tear instability, ocular surface epithelial damage, increase in inflammatory infiltrates and presence of increased lipid oxidation. PMID:21139696
Perényi, Kristóf; Dienes, Lóránt; Kornafeld, Anna; Kovács, Balázs; Kiss, Huba J; Szepessy, Zsuzsanna; Nagy, Zoltán Z; Barsi, Árpád; Acosta, M Carmen; Gallar, Juana; Kovács, Illés
To evaluate the effect of tear supplementation with preservative free 0.15% zinc-hyaluronate on ocular surface sensations and corneal sensitivity in dry eye patients. Ocular surface sensations were assessed using the ocular surface disease index (OSDI) questionnaire and by recording ocular sensations during forced blinking in parallel with noninvasive tear film breakup time measurement in 20 eyes of 20 dry eye patients. Corneal sensitivity thresholds to selective stimulation of corneal mechano-, thermal- and chemical receptors were measured using the Belmonte gas esthesiometer. All baseline measurements were repeated after 1 month of treatment with 0.15% zinc-hyaluronate. After 1 month, a significant decrease in mean OSDI score (from 35.66 ± 12.36 to 15.03 ± 11.22; P < 0.001) and a significant improvement in tear film breakup time (from 3.83 ± 0.80 to 8.67 ± 4.50 s; P < 0.001) was observed compared to baseline. Sensory responses during the interblink period also significantly decreased after 1 month (P < 0.004). Corneal sensitivity thresholds to mechanical stimulation (90.61 ± 20.35 vs. 103.92 ± 17.97 mL/min; P < 0.025) and chemical stimulation (33.21 ± 0.51 vs. 33.58% ± 0.44% CO 2 ; P < 0.025) significantly increased after 1 month, however sensitivity thresholds to thermal stimulation remained unchanged compared to baseline (P > 0.05). Prolonged use of 0.15% zinc-hyaluronate results in an improvement of tear film stability and a decrease of dry eye complaints. The decrease in corneal mechano-and polymodal receptor excitability suggests that zinc-hyaluronate helps to recover normal corneal sensitivity, and thus might have a beneficial additional effect on reducing ocular surface complaints in dry eye patients.
Corneal Expression of SLURP-1 by Age, Sex, Genetic Strain, and Ocular Surface Health
Swamynathan, Sudha; Delp, Emili E.; Harvey, Stephen A. K.; Loughner, Chelsea L.; Raju, Leela; Swamynathan, Shivalingappa K.
2015-01-01
Purpose Although secreted Ly6/urokinase-type plasminogen activator receptor–related protein-1 (Slurp1) transcript is highly abundant in the mouse cornea, corresponding protein expression remains uncharacterized. Also, SLURP1 was undetected in previous tear proteomics studies, resulting in ambiguity about its baseline levels. Here, we examine mouse corneal Slurp1 expression in different sexes, age groups, strains, and health conditions, and quantify SLURP1 in human tears from healthy or inflamed ocular surfaces. Methods Expression of Slurp1 in embryonic day-13 (E13), E16, postnatal day-1 (PN1), PN10, PN20, and PN70 Balb/C, FVBN, C57Bl/6, and DBA/2J mouse corneas, Klf4Δ/ΔCE corneas with corneal epithelial–specific ablation of Klf4, migrating cells in wild-type corneal epithelial wound edge, and in corneas exposed to pathogen-associated molecular patterns (PAMPs) poly(I:C), zymosan-A, or Pam3Csk4 was examined by QPCR, immunoblots, and immunofluorescent staining. Human SLURP1 levels were quantified by ELISA in tears from 34 men and women aged 18 to 80 years. Results Expression of Slurp1, comparable in different strains and sexes, was low in E13, E16, PN1, and PN10 mouse corneas, and increased rapidly after eyelid opening in a Klf4-dependent manner. We found Slurp1 was downregulated in corneas exposed to PAMPs, and in migrating cells at the wound edge. Human SLURP1 expression, comparable in different sexes and age groups, was significantly decreased in tears from inflamed ocular surfaces (0.34%) than those from healthy individuals (0.77%). Conclusions These data describe the influence of age, sex, genetic background, and ocular surface health on mouse corneal expression of Slurp1, establish the baseline for human tear SLURP1 expression, and identify SLURP1 as a useful diagnostic and/or therapeutic target for inflammatory ocular surface disorders. PMID:26670825
The tear film and ocular mucins.
Davidson, Harriet J; Kuonen, Vanessa J
2004-01-01
Abstract The trilaminar tear film, composed of the lipid, aqueous and mucin layers, has many functions including defending the ocular surface. The aqueous layer has several soluble antimicrobial factors that protect the ocular surface. Ocular mucins have recently been studied with regard to their role in the defense of the eye as well as in dry eye syndromes. To date, 15 mucin genes have been identified, and six of these mucin genes are localized to or secreted by ocular glands or epithelia. Understanding the production, secretion and function of ocular mucins will aid in the treatment of dry eye syndromes and ocular surface microbial infections.
Modelling the evaporation of a tear film over a contact lens.
Talbott, Kevin; Xu, Amber; Anderson, Daniel M; Seshaiyer, Padmanabhan
2015-06-01
A contact lens (CL) separates the tear film into a pre-lens tear film (PrLTF), the fluid layer between the CL and the outside environment, and a post-lens tear film (PoLTF), the fluid layer between the CL and the cornea. We examine a model for evaporation of a PrLTF on a modern permeable CL allowing fluid transfer between the PrLTF and the PoLTF. Evaporation depletes the PrLTF, and continued evaporation causes depletion of the PoLTF via fluid loss through the CL. Governing equations include Navier-Stokes, heat and Darcy's equations for the fluid flow and heat transfer in the PrLTF and porous layer. The PoLTF is modelled by a fixed pressure condition on the posterior surface of the CL. The original model is simplified using lubrication theory for the PrLTF and CL applied to a sagittal plane through the eye. We obtain a partial differential equation (PDE) for the PrLTF thickness that is first-order in time and fourth-order in space. This model incorporates evaporation, conjoining pressure effects in the PrLTF, capillarity and heat transfer. For a planar film, we find that this PDE can be reduced to an ordinary differential equation (ODE) that can be solved analytically or numerically. This reduced model allows for interpretation of the various system parameters and captures most of the basic physics contained in the model. Comparisons of ODE and PDE models, including estimates for the loss of fluid through the lens due to evaporation, are given. © The Authors 2014. Published by Oxford University Press on behalf of the Institute of Mathematics and its Applications. All rights reserved.
Atsumi, Satoru; Hara, Kunio; Arai, Yuji; Yamada, Manabu; Mizoshiri, Naoki; Kamitani, Aguri; Kubo, Toshikazu
2018-01-01
Abstract Rationale: Considering the risk of osteoarthritis following resection of a horizontally torn meniscus of the knee, repairing and preserving the meniscus as much as possible is preferred. We report 3 cases of restoration of horizontally torn menisci using a novel arthroscopic method we have called “all-inside interleaf vertical suture” that afforded preservation. Patient concerns: The 3 patients (aged 14, 17, and 21 years) had knee pain through sports activity. Diagnoses: All patients had horizontal tears in the posteromedial part of the meniscus. Interventions: The method uses Fast-Fix, whereby a first anchor is inserted from the tibial surface of the tear's superior leaflet and a second anchor is inserted from the femoral surface of the tear's inferior leaflet, and the 2 leaflets are closed using vertical suture. In all cases, the suture knots were embedded between the superior leaflet and inferior leaflet, avoiding contact with the articular cartilage, and superior leaflet and inferior leaflet crimping was good. Outcomes: All 3 were able to resume competing in sport and ≥ 1 year after surgery they had no pain and their postoperative mean Lysholm scores were 99.7. There were no complications or recurrence. On magnetic resonance imaging, the signal intensity of all the horizontal tears was high before surgery but low after surgery, suggesting that the repaired tear was healing. Lessons: The all-inside interleaf vertical suture procedure is a new surgical technique that can repair posteromedial horizontal meniscal tears of the knee of young people by easy crimping of the superior and inferior leaflets without the suture knots causing complications. PMID:29443758
Oxidative Stress Measures of Lipid and DNA Damage in Human Tears.
Haworth, Kristina M; Chandler, Heather L
2017-05-01
We evaluate feasibility and repeatability of measures for lipid peroxidation and DNA oxidation in human tears, as well as relationships between outcome variables, and compared our findings to previously reported methods of evaluation for ocular sun exposure. A total of 50 volunteers were seen for 2 visits 14 ± 2 days apart. Tear samples were collected from the inferior tear meniscus using a glass microcapillary tube. Oxidative stress biomarkers were quantified using enzyme-linked immunosorbent assay (ELISA): lipid peroxidation by measurement of hexanoyl-lysine (HEL) expression; DNA oxidation by measurement of 8-oxo-2'-deoxyguinosone (8OHdG) expression. Descriptive statistics were generated. Repeatability estimates were made using Bland-Altman plots with mean differences and 95% limits of agreement were calculated. Linear regression was conducted to evaluate relationships between measures. Mean (±SD) values for tear HEL and 8OHdG expression were 17368.02 (±9878.42) nmol/L and 66.13 (±19.99) ng/mL, respectively. Repeatability was found to be acceptable for both HEL and 8OHdG expression. Univariate linear regression supported tear 8OHdG expression and spring season of collection to be predictors of higher tear HEL expression; tear HEL expression was confirmed as a predictor of higher tear 8OHdG expression. We demonstrate feasibility and repeatability of estimating previously unreported tear 8OHdG expression. Seasonal temperature variation and other factors may influence tear lipid peroxidation. Support is demonstrated to suggest lipid damage and DNA damage occur concurrently on the human ocular surface.
Dry eye disease: pathophysiology, classification, and diagnosis.
Perry, Henry D
2008-04-01
Dry eye disease (DED) is a multifactorial disorder of the tear film and ocular surface that results in eye discomfort, visual disturbance, and often ocular surface damage. Although recent research has made progress in elucidating DED pathophysiology, currently there are no uniform diagnostic criteria. This article discusses the normal anatomy and physiology of the lacrimal functional unit and the tear film; the pathophysiology of DED; DED etiology, classification, and risk factors; and DED diagnosis, including symptom assessment and the roles of selected diagnostic tests.
Baudouin, Christophe; Aragona, Pasquale; Messmer, Elisabeth M; Tomlinson, Alan; Calonge, Margarita; Boboridis, Kostas G; Akova, Yonca A; Geerling, Gerd; Labetoulle, Marc; Rolando, Maurizio
2013-10-01
Dry eye disease (DED), a multifactorial disease of the tears and ocular surface, is common and has a significant impact on quality of life. Reduced aqueous tear flow and/or increased evaporation of the aqueous tear phase leads to tear hyperosmolarity, a key step in the vicious circle of DED pathology. Tear hyperosmolarity gives rise to morphological changes such as apoptosis of cells of the conjunctiva and cornea, and triggers inflammatory cascades that contribute to further cell death, including loss of mucin-producing goblet cells. This exacerbates tear film instability and drives the cycle of events that perpetuate the condition. Traditional approaches to counteracting tear hyperosmolarity in DED include use of hypotonic tear substitutes, which have relatively short persistence in the eye. More recent attempts to counteract tear hyperosmolarity in DED have included osmoprotectants, small organic molecules that are used in many cell types throughout the natural world to restore cell volume and stabilize protein function, allowing adaptation to hyperosmolarity. There is now an expanding pool of clinical data on the efficacy of DED therapies that include osmoprotectants such as erythritol, taurine, trehalose and L-carnitine. Osmoprotectants in DED may directly protect cells against hyperosmolarity and thereby promote exit from the vicious circle of DED physiopathology. Copyright © 2013 The Authors. Published by Elsevier Inc. All rights reserved.
Analysis of the Pathogenic Factors and Management of Dry Eye in Ocular Surface Disorders.
Nebbioso, Marcella; Del Regno, Paola; Gharbiya, Magda; Sacchetti, Marta; Plateroti, Rocco; Lambiase, Alessandro
2017-08-13
The tear film represents the interface between the eye and the environment. The alteration of the delicate balance that regulates the secretion and distribution of the tear film determines the dry eye (DE) syndrome. Despite having a multifactorial origin, the main risk factors are female gender and advanced age. Likewise, morphological changes in several glands and in the chemical composition of their secretions, such as proteins, mucins, lipidics, aqueous tears, and salinity, are highly relevant factors that maintain a steady ocular surface. Another key factor of recurrence and onset of the disease is the presence of local and/or systemic inflammation that involves the ocular surface. DE syndrome is one of the most commonly encountered diseases in clinical practice, and many other causes related to daily life and the increase in average life expectancy will contribute to its onset. This review will consider the disorders of the ocular surface that give rise to such a widespread pathology. At the end, the most recent therapeutic options for the management of DE will be briefly discussed according to the specific underlying pathology.
Analysis of the Pathogenic Factors and Management of Dry Eye in Ocular Surface Disorders
Del Regno, Paola; Sacchetti, Marta; Plateroti, Rocco
2017-01-01
The tear film represents the interface between the eye and the environment. The alteration of the delicate balance that regulates the secretion and distribution of the tear film determines the dry eye (DE) syndrome. Despite having a multifactorial origin, the main risk factors are female gender and advanced age. Likewise, morphological changes in several glands and in the chemical composition of their secretions, such as proteins, mucins, lipidics, aqueous tears, and salinity, are highly relevant factors that maintain a steady ocular surface. Another key factor of recurrence and onset of the disease is the presence of local and/or systemic inflammation that involves the ocular surface. DE syndrome is one of the most commonly encountered diseases in clinical practice, and many other causes related to daily life and the increase in average life expectancy will contribute to its onset. This review will consider the disorders of the ocular surface that give rise to such a widespread pathology. At the end, the most recent therapeutic options for the management of DE will be briefly discussed according to the specific underlying pathology. PMID:28805710
Effects of wearing a daily disposable lens on tear film: a randomised controlled trial.
Chong, Pamela Qin Yi; Yeo, Sharon; Too, Cheah Loon; Boo, Cynthia; Tong, Louis
2016-05-01
Contact lens-induced dry eye is commonly encountered, although its extent is not well documented with daily disposable lenses. A novel type of contact lens system incorporating moisturising agent (alginic acid) has been developed. The aim of this study was to evaluate the effect of wearing daily 2-hydroxyethyl methacrylate disposable contact lenses for seven days on tear stability, conjunctival and limbal redness and dry eye symptoms. Then, we aimed to determine whether lens solutions containing alginic acid had any influence on tear parameters. This was a seven-day parallel group double-masked clinical trial of previous contact lens wearers, where participants were randomly assigned to wearing SEED 1dayPure moisture contact lenses with (n = 15) or without alginic acid (n = 15). Tear lipid layer thickness (LLT), non-invasive tear break-up time (NIBUT), conjunctival redness, corneal fluorescein staining, tear break-up time and Schirmer I readings were measured. Symptom severity and frequency were evaluated and combined using a global score from visual analogue scales. The mean age and standard deviation of the participants was 25 ± 3.8 years. There were 24 females and six males. After reintroduction of contact lens wear for one week, there was significant improvement in the global symptom score; however, this may not be clinically significant. There were small and clinically insignificant changes in limbal and conjunctival hyperaemia but no significant changes in lipid layer thickness, Schirmer I and NIBUT in overall participants. The use of alginic acid in lens solutions did not affect these parameters compared to control lenses (p > 0.05). After seven days of wearing a modern daily disposable lens, there was no significant deterioration of tear function in a group of young contact lens wearers. In this short-term study, there was no evidence of significant benefit of lens solutions containing alginic acid used with HEMA lenses. © 2016 The Authors Clinical and Experimental Optometry © 2016 Optometry Australia.
Jacobi, Christina; Kruse, Friedrich E; Cursiefen, Claus
2012-12-01
The aim of this prospective, randomized, clinical, single-center study was to compare the safety and efficacy of 2 ocular surface lubricant eye drops: preservative-free hydroxypropyl (HP)-Guar (SYSTANE UD(®)) eye drops versus preservative-free Tamarindus indica seed polysaccharide (TSP) 1% (VISINE INTENSIV 1% EDO(®)) eye drops. Fifty-six eyes of 28 patients with moderate keratoconjunctivitis sicca (DEWS severity level 2) were enrolled in the trial. Patients were randomized for 2 treatment groups (SYSTANE UD eye drops vs. VISINE INTENSIV 1% EDO eye drops). The eye drops in both groups were applied 5 times per day for 3 months. Statistical analyses were performed using Statistica™ software (Mann-Whitney U-test and Wilcoxon test). P-Values<0.05 were considered significant. After 3 months of treatment the patients of both groups had subjective benefit in the relief of symptoms of dry eye disease evaluated by the Ocular Surface Disease Index (OSDI) questionnaire score. Patients treated with HP-Guar and TSP showed improvements in tear film stability measured by tear break-up time (TBUT), which are statistically significant in the HP-Guar group (P=0.02). The results of this clinical trial show improvements of symptoms and signs in patients with moderate dry eye after the consistent use of preservative-free HP-Guar and TSP lubricant eye drops. Both artificial tear formulations produce amelioration in tear film stability improving eye conditions and patient quality of life. HP-Guar seems to be slightly more effective in improving ocular surface protection by decreasing tear film evaporation.
Isotretinoin in lacrimal gland fluid and tears.
Rismondo, V; Ubels, J L
1987-03-01
Isotretinoin (13-cis-retinoic acid) is used in the treatment of severe cystic acne. Adverse ocular reactions, including blepharoconjunctivitis and dry eye symptoms, are frequent side effects of this drug. Our previous observation that retinol is present in tears and lacrimal gland fluid suggests that isotretinoin may also be secreted by the lacrimal gland. Rabbits were treated with isotretinoin, and lacrimal gland fluid was collected from the cannulated lacrimal gland duct. Tears were collected from patients who were being treated with isotretinoin. Lacrimal gland fluid and tears were analyzed by reverse-phase high-pressure liquid chromatography and a peak eluted from each sample, which was identified as isotretinoin. We conclude that the lacrimal gland is able to secrete isotretinoin in addition to retinol and that, in animals and patients treated systemically with isotretinoin, the ocular surface is exposed to the drug via the tear film.
Veselovskaya, N N; Zherebko, I B
Conducted a comparative analysis of functional changes in tear production in patients with dry eye syndrome and endocrine ophthalmopathy in the conditions of the long-term acting of preservative free medications based on natural substances. A total of 30 people, aged 35 to 53 years old with clinical manifestations of DES on the background of EO were divided on two groups. In I group eye drops of ectoine and in II - artificial tears were administered. The examination included general and specific methods. The term of follow up - 30 days. It was found that long-term use of preservative free eye drops based on ectoine leads to more expressive positive changes in the condition of the anterior surface of the eye and the secretion and quality of the tear.
Wojciechowska, Katarzyna; Jurowski, Piotr; Wieckowska-Szakiel, Marzena; Rózalska, Barbara
2012-01-01
Estimation of cytostatics influence used in breast cancer treatment on lysozyme activity in human tears depend on time of treatment. 8 women were treated at the base of chemotherapy schema: docetaxel with doxorubicin and 4 women treated with schema CMF: cyclophosphamide, methotrexate, 5-fluorouracil. Lysozyme activity in tears was assessed by measurement of diameter zone of Micrococcus lysodeicticus growth inhibition. It was revealed that both chemotherapy schema caused statistically significant reduction of diameter zone of M. lysodeicticus growth inhibition, after first and second course of chemotherapy treatment. After second chemotherapy course CMF schema induced loss of lysozyme activity in patient's tears (zero mm of M. lysodeicticus diameter zone growth inhibition). Systemic chemotherapy administered in breast cancer induce reduction of lysozyme activity in tears, that may cause higher morbidity of ocular surface infections caused by Gram-positive bacteria.
Guo, Nan; Jiao, Ting
2011-08-01
To study the effect of surface organic modified nano-silicon-oxide (SiO(x)) on mechanical properties of A-2186 silicone elastomers. Surface organic modified nano-silicon-oxide (SiO(x)) was added into A-2186 silicone elastomers by weight percentage of 2%, 4% and 6%. The one without addition served as a control. Standard specimens were made according to American Society for Testing Materials (ASTM). Their tensile strength, elongation at break, tear strength, and Shore A hardness were measured. The results were analyzed statistically by SPSS 10.0 software package. The tensile strength in the experimental groups was significantly lower than the control group (P<0.001).The elongation in the experimental groups was lower than the control group, but there was no significant difference between the 2wt% group and the control group (P=0.068). The tear strength in both the 2wt= group and 4wt= group were higher than the control group, and the difference was statistically significant; in addition, the tear strength in 2wt= group was higher than 4wt= group, which also showed statistical significance (P<0.001). With the increase of the added amount of surface modified nano-SiO(x), Shore A hardness increased and there was significant difference among them (P<0.001). Adding surface modified nano-SiO(x) has an effect on mechanical properties of A-2186 silicone elastomer, when 2wt= and 4wt= are added, tear strength of A-2186 improves significantly, with an increase of Shore A hardness and an decrease of tensile strength.
Dry eye disease: an immune-mediated ocular surface disorder
Stevenson, William; Chauhan, Sunil K.; Dana, Reza
2013-01-01
Dry eye disease is a multifactorial disorder of the tears and ocular surface characterized by symptoms of dryness and irritation. Although the pathogenesis of dry eye disease is not fully understood, it is recognized that inflammation has a prominent role in the development and propagation of this debilitating condition. Factors that adversely affect tear film stability and osmolarity can induce ocular surface damage and initiate an inflammatory cascade that generates innate and adaptive immune responses. These immunoinflammatory responses lead to further ocular surface damage and the development of a self-perpetuating inflammatory cycle. Herein, we review the fundamental links between inflammation and dry eye disease and discuss the clinical implications of inflammation in disease management. PMID:22232476
Tear film and ocular surface assessment in psoriasis.
Aragona, Emanuela; Rania, Laura; Postorino, Elisa Imelde; Interdonato, Alberto; Giuffrida, Roberta; Cannavò, Serafinella Patrizia; Puzzolo, Domenico; Aragona, Pasquale
2018-03-01
Psoriasis is a skin disease with also systemic involvement: its impact on the eye is not well established and often clinically underestimated. Aim of this study was to investigate the presence of ocular discomfort symptoms and of ocular surface changes in a population of patients with psoriasis. For this cross-sectional, comparative study, 66 patients with psoriasis were subdivided according to the presence of arthritis and to the use of biological therapy. All patients underwent clinical evaluation with the following tests: Ocular Surface Disease Index Questionnaire, Tearscope examination, meibometry, tear film breakup time, corneal and conjunctival fluorescein staining, Schirmer I test, corneal aesthesiometry, meibomian gland dysfunction (MGD) assessment and conjunctival impression cytology. 28 healthy subjects were also enrolled and treated with the same clinical tests. A statistical analysis of the results was performed. Patients with psoriasis showed a significant deterioration of the ocular surface tests, if compared with healthy subjects, demonstrated by tear film lipid layer alteration, tear film instability, corneal and conjunctival epithelial suffering and mild squamous metaplasia at impression cytology. No differences were found in ocular surface test results of the psoriatic group when patients were divided according to the presence of arthritis, whereas the anti-inflammatory treatment with biological drugs demonstrated a significant improvement of corneal stain and MGD. Our findings suggest that the ocular surface involvement in patients with psoriasis indicates the need of periodic ophthalmological examinations to diagnose the condition and allow a proper treatment, so contributing to the amelioration of patients' quality of life. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Harryman, Douglas T; Hettrich, Carolyn M; Smith, Kevin L; Campbell, Barry; Sidles, John A; Matsen, Frederick A
2003-04-01
Rotator cuff tears are among the most common conditions of the shoulder. One of the major difficulties in studying patients with rotator cuff tears is that the clinical expression of these tears varies widely and different practices may have substantially different patient populations. The goals of the present prospective multipractice study were to use patient self-assessment questionnaires (1) to identify some of the characteristics of patients with rotator cuff tears, other than the size of the cuff tear, that are correlated with shoulder function, and (2) to determine whether there are significant differences in these characteristics among patients from the practices of different surgeons. Ten surgeons enrolled a total of 333 patients with a full-thickness tear of the supraspinatus tendon into this prospective study. Each patient completed self-assessment questionnaires that included items regarding demographic characteristics, prior treatment, medical and social comorbidities, general health status, and shoulder function. As expected, patients who had an infraspinatus tendon tear as well as a supraspinatus tendon tear had significantly worse ability to use the arm overhead compared with those who had a supraspinatus tear alone (p < 0.005). However, shoulder function and health status were correlated with patient characteristics other than the size of the rotator cuff tear. The number of shoulder functions that were performable was correlated with the subscales of the Short Form-36 and was inversely associated with medical and social comorbidities. The patients from the ten different surgeon practices showed significant differences in almost every parameter, including age, gender, method of tear documentation, tear size, prior treatment, medical and social comorbidities, general health status, and shoulder function. Clinical studies on the natural history of rotator cuff tears and the effectiveness of treatment must control for a wide range of variables, many of which do not pertain directly to the shoulder. Patients from the practices of different surgeons cannot be assumed to be similar with respect to these variables. Patient self-assessment questionnaires appear to offer a practical method of uniform assessment across different practices.
Contact Lens Anterior Surface pH
1991-02-01
greenhouse effect and contact lenses, in Trans- 4. Nom MS: Tear fluid pH in normals, contact lens wearers, actions of the British Contact Lens...Invest 3. Fullard R), Carney LG: Diurnal variation in human tear en- Op/hdanmol Vis Sci 1978;17:810-813. ymes. Exp Eye Res 1984;38:15-26. 20. Efron N: The
ERIC Educational Resources Information Center
Gugliotti, Marcos
2004-01-01
The unique occurrence of the upward motion of a thin film of wine, and its formation into drops inside the wall of a wine glass is explained. Evaporation of alcohol generates a surface tension gradient, moving the film of wine upwards on the internal sides of a wine glass, where it collects and forms into drops or tears.
Current profile redistribution driven by neutral beam injection in a reversed-field pinch
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parke, E.; Department of Physics, University of Wisconsin-Madison 1150 University Ave., Madison, Wisconsin 53706; Anderson, J. K.
2016-05-15
Neutral beam injection in reversed-field pinch (RFP) plasmas on the Madison Symmetric Torus [Dexter et al., Fusion Sci. Technol. 19, 131 (1991)] drives current redistribution with increased on-axis current density but negligible net current drive. Internal fluctuations correlated with tearing modes are observed on multiple diagnostics; the behavior of tearing mode correlated structures is consistent with flattening of the safety factor profile. The first application of a parametrized model for island flattening to temperature fluctuations in an RFP allows inferrence of rational surface locations for multiple tearing modes. The m = 1, n = 6 mode is observed to shift inward by 1.1 ± 0.6 cm withmore » neutral beam injection. Tearing mode rational surface measurements provide a strong constraint for equilibrium reconstruction, with an estimated reduction of q{sub 0} by 5% and an increase in on-axis current density of 8% ± 5%. The inferred on-axis current drive is consistent with estimates of fast ion density using TRANSP [Goldston et al., J. Comput. Phys. 43, 61 (1981)].« less
Semeraro, Francesco; Forbice, Eliana; Nascimbeni, Giuseppe; Taglietti, Marco; Romano, Vito; Guerra, Germano; Costagliola, Ciro
To evaluate in vivo changes after therapy using autologous serum (AS) eye drops in Sjögren's syndrome (SS)-related dry eyes by confocal microscopy. In this study, 24 patients with SS-related dry eyes [12 in AS eye drop therapy and 12 in artificial tear (AT) therapy] and 24 healthy volunteers were recruited. Ocular Surface Disease Index (OSDI), central corneal thickness, tear film, break-up time, corneal and conjunctival staining, Schirmer's test and corneal confocal microscopy were investigated. Tear production, tear stability, corneal staining, inflammation, and central corneal thickness, Langherans cells, activated keratocytes, intermediate epithelial cell density, nerve tortuosity, number of sub-basal nerve branches, and number of bead-like formations differed between patients and controls (p<0.0001). The AT and AS groups differed in the OSDI, number of branches, and number of beadings (p<0.0001). AS eye drops improve symptoms and confocal microscopy findings in SS-related dry eyes. Copyright © 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.
Effects of resonant magnetic perturbation on the triggering and the evolution of double-tearing mode
NASA Astrophysics Data System (ADS)
Wang, L.; Lin, W. B.; Wang, X. Q.
2018-02-01
The effects of resonant magnetic perturbation on the triggering and the evolution of the double-tearing mode are investigated by using nonlinear magnetohydrodynamics simulations in a slab geometry. It is found that the double-tearing mode can be destabilized by boundary magnetic perturbation. Moreover, the mode has three typical development stages before it reaches saturation: the linear stable stage, the linear-growth stage, and the exponential-growth stage. The onset and growth of the double-tearing mode significantly depend on the boundary magnetic perturbations, particularly in the early development stage of the mode. The influences of the magnetic perturbation amplitude on the mode for different separations of the two rational surfaces are also discussed.
Differences in ocular parameters between diurnal and nocturnal raptors.
Beckwith-Cohen, Billie; Horowitz, Igal; Bdolah-Abram, Tali; Lublin, Avishai; Ofri, Ron
2015-01-01
To establish and compare normal ocular parameters between and within diurnal and nocturnal raptor groups. Eighty-eight ophthalmically normal raptors of six nocturnal and 11 diurnal species were studied. Tear production was measured using Schirmer tear test (STT) and phenol red thread test (PRTT), and applanation tonometry was conducted. Ultrasonographic measurements of axial length (AL), mediolateral axis (ML), vitreous body (VB), and pecten length (PL) were recorded, and conjunctival cultures were obtained. A weak correlation (R = 0.312, P = 0.006) was found between PRTT and STT. Tear production was significantly lower in nocturnal species (P < 0.001), but no difference was observed in intraocular pressure (IOP). VB and PL were significantly longer in diurnals (P < 0.001 and P = 0.021, respectively), and no significant difference was observed in AL and ML. When comparing results within these groups, there was a significant difference between most species for all parameters except IOP. Fifty-one percent of the examined raptors were positive for mycology or bacteriology, either on culture or PCR. The most common infectious agent isolated was Staphylococcus spp. Phenol red thread test and STT are both valid methods to measure tear production; however, a separate baseline must be determined for each species using these methods, as the results of one method cannot be extrapolated to the other. Due to significant differences observed within diurnal and nocturnal species, it appears that a more intricate division should be used when comparing these parameters for raptors, and the classification of diurnal or nocturnal holds little significance in the baseline of these data. © 2013 American College of Veterinary Ophthalmologists.
Kojima, Takashi; Dogru, Murat; Ibrahim, Osama M; Nagata, Taeko; Higa, Kazunari; Shimizu, Takahiko; Shirasawa, Takuji; Satake, Yoshiyuki; Shimazaki, Seika; Shimazaki, Jun; Tsubota, Kazuo
2014-01-01
To investigate the role of a water and mucin secretagogue (3% diquafosol sodium eye drops) on the tear function and conjunctival ocular surface changes in Sod1(-/-) in comparison to the wild-type (WT) mice. Fourteen eyes of 7 Sod1(-/-) male mice with C57BL/background and 14 eyes of 7 C57BL6 strain wild-type male mice were examined at 40 weeks in this study. All mice had application of 3% diquafosol ophthalmic solution six times a day for 2 weeks. Tear film stability and corneal epithelial damage was evaluated by fluorescein and Rose Bengal stainings. Anterior segment photography was performed before and after eye drop instillations. Aqueous tear quantity was measured with phenol red-impregnated cotton threads without anesthesia. Animals were sacrificed at 42 weeks after diquafosol treatment and the whole globe specimens were subjected to periodic acid Schiff staining. Goblet cell density was quantified by J Image software. Quantitative real-time PCR for conjunctival muc 5AC messenger RNA expression was also performed. Sod1(-/-) mice had significantly higher fluorescein staining scores compared to the WT mice before eye drop instillation. The mean tear film breakup time, Rose Bengal staining scores, and muc5 messenger RNA expression improved significantly with diquafosol treatment in both the WT and the knockout mice. The mean fluorescein staining score and aqueous tear quantity significantly improved in the Sod1(-/-) mice with treatment. A notable and consistent increase in goblet cells and decrease in inflammatory cell infiltrates could be confirmed in all specimens after 2 weeks of diquafosol eye drop application. Three percent diquafosol ophthalmic solution appears to be effective in the treatment of ocular surface disease in this age-related dry eye disease mouse model.
NASA Astrophysics Data System (ADS)
Basiuk, V.; Huynh, P.; Merle, A.; Nowak, S.; Sauter, O.; Contributors, JET; the EUROfusion-IM Team
2017-12-01
The neoclassical tearing modes (NTM) increase the effective heat and particle radial transport inside the plasma, leading to a flattening of the electron and ion temperature and density profiles at a given location depending on the safety factor q rational surface (Hegna and Callen 1997 Phys. Plasmas 4 2940). In burning plasma such as in ITER, this NTM-induced increased transport could reduce significantly the fusion performance and even lead to a disruption. Validating models describing the NTM-induced transport in present experiment is thus important to help quantifying this effect on future devices. In this work, we apply an NTM model to an integrated simulation of current, heat and particle transport on JET discharges using the European transport simulator. In this model, the heat and particle radial transport coefficients are modified by a Gaussian function locally centered at the NTM position and characterized by a full width proportional to the island size through a constant parameter adapted to obtain the best simulations of experimental profiles. In the simulation, the NTM model is turned on at the same time as the mode is triggered in the experiment. The island evolution is itself determined by the modified Rutherford equation, using self-consistent plasma parameters determined by the transport evolution. The achieved simulation reproduces the experimental measurements within the error bars, before and during the NTM. A small discrepancy is observed on the radial location of the island due to a shift of the position of the computed q = 3/2 surface compared to the experimental one. To explain such small shift (up to about 12% with respect to the position observed from the experimental electron temperature profiles), sensitivity studies of the NTM location as a function of the initialization parameters are presented. First results validate both the transport model and the transport modification calculated by the NTM model.
Tong, Louis; Zhou, Xi Yuan; Jylha, Antti; Aapola, Ulla; Liu, Dan Ning; Koh, Siew Kwan; Tian, Dechao; Quah, Joanne; Uusitalo, Hannu; Beuerman, Roger W; Zhou, Lei
2015-02-06
Tear proteins are intimately related to the pathophysiology of the ocular surface. Many recent studies have demonstrated that the tear is an accessible fluid for studying eye diseases and biomarker discovery. This study describes a high resolution multiple reaction monitoring (HR-MRM) approach for developing assays for quantification of biologically important tear proteins. Human tear samples were collected from 1000 subjects with no eye complaints (411 male, 589 female, average age: 55.5±14.5years) after obtaining informed consent. Tear samples were collected using Schirmer's strips and pooled into a single global control sample. Quantification of proteins was carried out by selecting "signature" peptides derived by trypsin digestion. A 1-h nanoLC-MS/MS run was used to quantify the tear proteins in HR-MRM mode. Good reproducibility of signal intensity (using peak areas) was demonstrated for all 47 HR-MRM assays with an average coefficient of variation (CV%) of 4.82% (range: 1.52-10.30%). All assays showed consistent retention time with a CV of less than 0.80% (average: 0.57%). HR-MRM absolute quantitation of eight tear proteins was demonstrated using stable isotope-labeled peptides. In this study, we demonstrated for the first time the technique to quantify 47 human tear proteins in HR-MRM mode using approximately 1μl of human tear sample. These multiplexed HR-MRM-based assays show great promise of further development for biomarker validation in human tear samples. Both discovery-based and targeted quantitative proteomics can be achieved in a single quadrupole time-of-flight mass spectrometer platform (TripleTOF 5600 system). Copyright © 2015 Elsevier B.V. All rights reserved.
Incomplete response to artificial tears is associated with features of neuropathic ocular pain.
Galor, Anat; Batawi, Hatim; Felix, Elizabeth R; Margolis, Todd P; Sarantopoulos, Konstantinos D; Martin, Eden R; Levitt, Roy C
2016-06-01
Artificial tears are first-line therapy for patients with dry eye symptoms. It is not known, however, which patient factors associate with a positive response to therapy. The purpose of this study was to evaluate whether certain ocular and systemic findings are associated with a differential subjective response to artificial tears. Cross-sectional study of 118 individuals reporting artificial tears use (hypromellose 0.4%) to treat dry eye-associated ocular pain. An evaluation was performed to assess dry eye symptoms (via the dry eye questionnaire 5 and ocular surface disease index), ocular and systemic (non-ocular) pain complaints and ocular signs (tear osmolarity, tear breakup time, corneal staining, Schirmer testing with anaesthesia, and eyelid and meibomian gland assessment). The main outcome measures were factors associated with differential subjective response to artificial tears. By self-report, 23 patients reported no improvement, 73 partial improvement and 22 complete improvement in ocular pain with artificial tears. Patients who reported no or partial improvement in pain with artificial tears reported higher levels of hot-burning ocular pain and sensitivity to wind compared with those with complete improvement. Patients were also asked to rate the intensity of systemic pain elsewhere in the body (other than the eye). Patients who reported no or incomplete improvement with artificial tears had higher systemic pain scores compared with those with complete improvement. Both ocular and systemic (non-ocular) pain complaints are associated with a differential subjective response to artificial tears. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Neoclassical tearing mode seeding by coupling with infernal modes in low-shear tokamaks
NASA Astrophysics Data System (ADS)
Kleiner, A.; Graves, J. P.; Brunetti, D.; Cooper, W. A.; Halpern, F. D.; Luciani, J.-F.; Lütjens, H.
2016-09-01
A numerical and an analytical study of the triggering of resistive MHD modes in tokamak plasmas with low magnetic shear core is presented. Flat q profiles give rise to fast growing pressure driven MHD modes, such as infernal modes. It has been shown that infernal modes drive fast growing islands on neighbouring rational surfaces. Numerical simulations of such instabilities in a MAST-like configuration are performed with the initial value stability code XTOR-2F in the resistive frame. The evolution of magnetic islands are computed from XTOR-2F simulations and an analytical model is developed based on Rutherford’s theory in combination with a model of resistive infernal modes. The parameter {{Δ }\\prime} is extended from the linear phase to the non-linear phase. Additionally, the destabilising contribution due to a helically perturbed bootstrap current is considered. Comparing the numerical XTOR-2F simulations to the model, we find that coupling has a strong destabilising effect on (neoclassical) tearing modes and is able to seed 2/1 magnetic islands in situations when the standard NTM theory predicts stability.
Stabilizing effect of helical current drive on tearing modes
NASA Astrophysics Data System (ADS)
Yuan, Y.; Lu, X. Q.; Dong, J. Q.; Gong, X. Y.; Zhang, R. B.
2018-01-01
The effect of helical driven current on the m = 2/n = 1 tearing mode is studied numerically in a cylindrical geometry using the method of reduced magneto-hydro-dynamic simulation. The results show that the local persistent helical current drive from the beginning time can be applied to control the tearing modes, and will cause a rebound effect called flip instability when the driven current reaches a certain value. The current intensity threshold value for the occurrence of flip instability is about 0.00087I0. The method of controlling the development of tearing mode with comparative economy is given. If the local helical driven current is discontinuous, the magnetic island can be controlled within a certain range, and then, the tearing modes stop growing; thus, the flip instability can be avoided. We also find that the flip instability will become impatient with delay injection of the driven current because the high order harmonics have been developed in the original O-point. The tearing mode instability can be controlled by using the electron cyclotron current drive to reduce the gradient of the current intensity on the rational surfaces.
NASA Astrophysics Data System (ADS)
Aranha dos Santos, Valentin; Schmetterer, Leopold; Gröschl, Martin; Garhofer, Gerhard; Werkmeister, René M.
2016-03-01
Dry eye syndrome is a highly prevalent disease of the ocular surface characterized by an instability of the tear film. Traditional methods used for the evaluation of tear film stability are invasive or show limited repeatability. Here we propose a new noninvasive approach to measure tear film thickness using an efficient delay estimator and ultrahigh resolution spectral domain OCT. Silicon wafer phantoms with layers of known thickness and group index were used to validate the estimator-based thickness measurement. A theoretical analysis of the fundamental limit of the precision of the estimator is presented and the analytical expression of the Cramér-Rao lower bound (CRLB), which is the minimum variance that may be achieved by any unbiased estimator, is derived. The performance of the estimator against noise was investigated using simulations. We found that the proposed estimator reaches the CRLB associated with the OCT amplitude signal. The technique was applied in vivo in healthy subjects and dry eye patients. Series of tear film thickness maps were generated, allowing for the visualization of tear film dynamics. Our results show that the central tear film thickness precisely measured in vivo with a coefficient of variation of about 0.65% and that repeatable tear film dynamics can be observed. The presented method has the potential of being an alternative to breakup time measurements (BUT) and could be used in clinical setting to study patients with dry eye disease and monitor their treatments.
Millar, Thomas J; Tragoulias, Sophia T; Anderton, Philip J; Ball, Malcolm S; Miano, Fausto; Dennis, Gary R; Mudgil, Poonam
2006-01-01
Ocular mucins are thought to contribute to the stability of the tear film by reducing surface tension. The purpose of this study was to compare the effect of different mucins and hyaluronic acid (HA) alone and mixed with meibomian lipids on the surface pressure at an air-liquid interface. A Langmuir trough and Wilhelmy balance were used to measure and compare the surface activity of bovine submaxillary gland mucin (BSM), purified BSM, purified bovine ocular mucin and HA, and mixtures of these with meibomian lipids, phosphatidylcholine, and phosphatidylglycerol. Their appearance at the surface of an air-buffer interface was examined using epifluorescence microscopy. Purified ocular mucin had no surface activity even at concentrations that were 100 times more than normally occur in tears. By contrast, commercial BSM caused changes to surface pressure that were concentration dependent. The surface pressure-area profiles showed surface activity with maximum surface pressures of 12.3-22.5 mN/m depending on the concentration. Purified BSM showed no surface activity at low concentrations, whereas higher concentrations reached a maximum surface pressure of 25 mN/m. HA showed no surface activity, at low or high concentrations. Epifluorescence showed that the mucins were located at the air-buffer interface and changed the appearance of lipid films. Purified bovine ocular mucin and HA have no surface activity. However, despite having no surface activity in their own right, ocular mucins are likely to be present at the surface of the tear film, where they cause an increase in surface pressure by causing a compression of the lipids (a reorganization of the lipids) and alter the viscoelastic properties at the surface.
Molina-Leyva, Ignacio; Molina-Leyva, Alejandro; Bueno-Cavanillas, Aurora
2017-12-01
To critically appraise scientific evidence regarding the efficacy of nutritional supplementation with omega-3 and omega-6 fatty acids for the treatment of dry eye syndrome (DES). A systematic review of randomized clinical trials was performed. Two independent reviewers selected and analysed the scientific papers that met inclusion and exclusion criteria. Objective and subjective efficacy outcomes were assessed. The trials involved a total of 2591 patients in fifteen independent studies. All studies were published between 2005 and 2015. The supplements used were mostly omega-3 and omega-6 in different proportions. Subjective improvement was measured using mainly Ocular Surface Disease Index (OSDI) test and Dry Eye Severity Score (DESS) test: significant differences in favour of the experimental group were found in seven of the studies. The objective amelioration was assessed by lacrimal function parameters: Tear break-up time (TBUT) significantly increased in nine studies and Schirmer's test in four studies. We observed a discrete improvement in the parameters of tear function. Scientific evidence is not strong enough to systematically recommend the use of omega-3 and omega-6 fatty acids as a standalone treatment of DES independently from its aetiology. However, they could be considered as an effective alternative to topical treatment in patients with DES secondary to certain pathologies. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Ophthalmic parameters in adult lowland paca (Cuniculus paca) raised in captivity.
Balthazar da Silveira, Camila P; Lima, Tiago B; Crivelaro, Roberta M; de Lacerda, Luciana C C; Pádua, Ivan R M; Renzo, Roberta; de Barros Sobrinho, Alexandre A F; Oliveira, Fabrício S; Aldrovani, Marcela; Laus, José L
2018-01-01
To investigate the ophthalmic parameters of lowland pacas, including the anatomic features, tear production, intraocular pressure, central corneal thickness, and morphology of the corneal endothelium. Thirteen adult, anesthetized Cuniculus paca. Eyes were evaluated using slit-lamp biomicroscopy, the Schirmer tear test I, digital applanation tonometry, binocular indirect ophthalmoscopy, and noncontact specular microscopy. The biomicroscopy findings showed blue/brown pigmented bulbar conjunctivae, well-developed cilia (only in the upper eyelid margin), superior and inferior lacrimal puncta, brown irides, round pupils, and vestiges of the nictitating membrane. The results of the Schirmer tear test I revealed (mean ± SD) a lacrimation rate of 4.10 ± 0.44 mm/min. The intraocular pressure was 6.34 ± 0.43 mmHg. Central corneal thickness measured by specular microscopy was 0.35 ± 0.01 mm. The mean values of density, hexagonality, and the area of the endothelial cells were 2083.15 ± 42.47 cells/mm 2 , 67.07 ± 3.30%, and 486.30 ± 9.56 μm 2 , respectively. The ocular parameters defined in this study may be used for reference in future studies and might also contribute to therapeutic approaches appropriate to this species. © 2017 American College of Veterinary Ophthalmologists.
Burkhardt, Rino; Ruiz Magaz, Vanessa; Hämmerle, Christoph H F; Lang, Niklaus P
2016-04-01
The aim of this study was to evaluate the role of a connective tissue graft (CTG) or a collagen matrix (CM) interpositioned between flaps and non-shedding hard surfaces on wound stability. Sixty bone dehiscence defects were prepared in five Beagle dogs. Three treatments were performed in 12 sites per dog: (1) repositioned flaps were sutured onto instrumented dentin surfaces (control), (2) repositioning of flaps with an interpositioned CTG and (3) repositioning of flaps with the application of a CM. To allow postoperative healing with n = 5 for 1, 3, 7 and 14 days before evaluation, the sutures were removed, incision lines retraced and tensile forces applied to the flaps. The minimum magnitude of forces required to detach the flaps from the wound bed was recorded. After 1 week of healing, 6 N had to be applied to disrupt flaps from their wound bed in the CTG group. In the control group, a similar magnitude of resistance was achieved after 2 weeks (6.1 N). Flap resistance to tearing was highest in the CTG group (maximum 9.1 N) 2 weeks postoperatively. On the third postoperative day, the mean tearing forces of all groups differed significantly, displaying a 50% lower resistance to tearing in the CM compared to the CTG group. In comparison, flap resistance to tearing forces established earlier and in higher magnitude in sites with an interpositioned CTG than in flaps repositioned on dentin or CM. Application of a CTG, sutured to a non-shedding hard surface, significantly increased flap resistance to tearing when applying disrupting forces compared to controls. A less pronounced effect was achieved by interpositioning of a CM. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Compatibility of phospholipid liposomal spray with silicone hydrogel contact lens wear.
Wang, Michael T M; Ganesalingam, Kalaivarny; Loh, Chee Seang; Alberquerque, Trisha; Al-Kanani, Suhaila; Misra, Stuti L; Craig, Jennifer P
2017-02-01
To assess the effects of two weeks of regular phospholipid liposomal spray application on lipid layer grade, tear film stability, subjective comfort, visual acuity, and lipid deposition in silicone hydrogel contact lens wearers. Thirty-one existing contact lens wearers were enrolled and fitted with two week planned replacement silicone hydrogel contact lenses (Acuvue ® Oasys ® ) in a prospective, randomized, paired-eye, investigator-masked trial. A phospholipid liposomal spray (Tears Again ® ) was applied to one eye (randomized) four times daily for two weeks. LogMAR high contrast visual acuity (VA), low contrast glare acuity (LCGA), non-invasive tear film break-up time (NIBUT), and lipid layer grade (LLG) were measured at baseline and day 14, in both treated and control eyes. Subjective comfort relative to baseline, and spectrofluorophotometric assessment of contact lens surface lipid deposition were also assessed on day 14. All measurements did not differ at baseline between treated and control eyes. Lipid layer thickness and tear film stability were increased on day 14 in treated eyes (all p<0.05), but not in control eyes (all p>0.05). A greater proportion of participants reported improved comfort in the treated eye relative to the control eye (p=0.002). There were no significant differences in visual acuity or in contact lens surface lipid deposition, between treated and control eyes, on day 14 (all p>0.05). The phospholipid liposomal spray increased tear film stability, lipid layer thickness and subjective comfort in silicone hydrogel contact lens wearers, without adversely affecting visual acuity or contact lens surface lipid deposition. Copyright © 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Tear film aberration dynamics and vision-related quality of life in patients with dry eye disease.
Denoyer, Alexandre; Rabut, Ghislaine; Baudouin, Christophe
2012-09-01
Corneal and ocular wavefront aberrations were recorded together with clinical examination results and patient-reported vision-related quality-of-life evaluation results to define the relevance of dynamic optical analysis of the eye in dry eye disease (DED). Prospective and comparative clinical study. Forty DED patients and 40 age- and gender-matched control subjects. Serial measurements of ocular and corneal higher-order aberrations (HOAs) after blink were performed for 10 seconds using the KR-1 aberrometer (Topcon, Clichy, France). Vision-related health-targeted quality of life was evaluated using the Ocular Surface Disease Index (OSDI) questionnaire. The clinical examination included tear film assessment (tear film break-up time and Schirmer I test), ocular surface damage assessment with the Oxford and van Bijsterveld indexes, and Meibomian dysfunction grading. Tear osmolarity also was measured. The time course of HOAs and modulation transfer function (MTF) was compared between groups and was analyzed in comparison with the OSDI and clinical data in DED patients. The root mean square of ocular and corneal total HOAs, particularly third-order aberrations, significantly increased over the 10-second period in DED patients, whereas no change occurred in controls. Analysis of MTF revealed progressive degradation of ocular optical quality resulting from loss of contrast at intermediate and high spatial frequencies in DED patients compared with controls. The progression index for corneal HOAs was correlated with the subjective index of patient-reported visual outcomes and with objective clinical findings of tear film and ocular surface damage. Objective measurement of the time course of HOAs may constitute a new single instrument to evaluate and manage patients with DED because it reliably reflects the completeness of the disease. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Asbell, Penny A
2006-11-01
Dry eye syndrome is a highly prevalent, yet largely under diagnosed, condition that can substantially affect quality of life. Left untreated, dry eye is associated with chronic eye pain and increased risk of ocular surface disease. Current demographic changes and lifestyle factors indicate that the dry eye syndrome patient population will increase significantly, ensuring that general practitioners and ophthalmic clinicians alike will experience more patients presenting with dry eye symptoms. Greater public and practitioner awareness of emerging research, technologies, and therapies is crucial to ensuring appropriate interventions to meet specific patient needs and result in clinically favorable outcomes. In August 2005, a team of ocular surface experts convened for a 1-day roundtable session to discuss the latest information on diagnosing and treating dry eye syndrome and real-world issues in artificial tear therapy, including preservative use. The discussion centered on the mild to moderate dry eye patient and critical features of the ideal artificial tear, which are preservative-free formulation, protection from microbial contamination, cost-effective, non-blurring, and easy to use. Products that match this profile have the advantage of being able to benefit the myriad of patients who comprise the dry eye syndrome population. Ocular surface health should always remain a top priority. Preferred Practice Pattern Dry Eye Syndrome Medical Treatment guidelines should be modified to recommend the use of preservative-free formula artificial tear products for all levels of dry eye conditions in consideration of the medical benefit they offer to dry eye syndrome sufferers. The growing prevalence of dry eye syndrome demands increased attention. Further research, enhanced diagnostic tests, increased use of preservative-free artificial tear formulations as first-line therapy, greater patient-practitioner interaction, and patient education are warranted.
Yildiz Tasci, Yelda; Gürdal, Canan; Sarac, Ozge; Onusever, Aykut
2017-07-01
To evaluate the effects of three different silicone hydrogel contact lenses (SHCL), (balafilcon A, senofilcon A, and comfilcon A) on tear function tests, corneal thickness, and ocular surface cytology in first time contact lens users. In this prospective study, 120 eyes of 60 subjects were evaluated. Balafilcon A users were designated as group 1, senofilcon A users as group 2, and comfilcon A users as group 3. In all cases, before and after 6 months of contact lens wear, ocular surface disease index score (OSDI), tear breakup time (TBUT), Schirmer 1 test, central corneal thickness (CCT), central corneal epithelium thickness (CCET), and conjunctival impression cytology samples were evaluated. In group 1, 40 eyes of the 20 patients, in group 2, 40 eyes of the 20 patients, and in group 3, 40 eyes of the 20 patients were evaluated. The mean OSDI scores did not differ between the three groups after contact lens wear (p > 0.05). In group 1 and group 2, significant decrease was found in the mean TBUT 6 months after contact lens wear (p = 0.04, p < 0.001, respectively). In group 3, after 6 months of contact lens wear, the mean Schirmer 1 tear test was decreased significantly (p = 0.021). In all 3 groups, no significant change was observed in the mean CCT and CCET after contact lens wear (p > 0.05). After 6 months, the morphological changes in temporal and superior conjunctival epithelial cells were found to be significant in all groups (p < 0.001). Six months after SHCL wear, marked morphological changes occurred in the conjunctival epithelium. Tear function tests were also affected, while corneal thickness did not show any significant difference.
Antimicrobial role of human meibomian lipids at the ocular surface.
Mudgil, Poonam
2014-10-14
Human meibomian lipids form the outermost lipid layer of the tear film and serve many important functions to maintain its integrity. Although not investigated earlier, these lipids may have antimicrobial properties that help in strengthening the innate host defense of tears at the ocular surface. The aim of this study was to investigate the antimicrobial role of human meibomian lipids. Ocular pathogenic bacteria, Staphylococcus aureus 31, Pseudomonas aeruginosa 19, Pseudomonas aeruginosa 20, and Serratia marcescens 35, were grown in the presence and absence of human meibomian lipids in an artificial tear solution at the physiological temperature. Viable counts were obtained to note the number of bacteria surviving the treatment with meibomian lipids. Bacterial cells were imaged using scanning electron microscopy to observe the damages caused by meibomian lipids. Viable count results showed that in the presence of meibomian lipids, growth of all bacteria was considerably lower. Scanning electron microscopy showed that meibomian lipids caused extensive cellular damage to bacteria as manifested in smaller size, loss of aggregation, abnormal phenotype, cellular distortion, damaged cell wall, and cell lysis. This is the first-ever report of the antimicrobial role of human meibomian lipids. These lipids possess antimicrobial properties against both Gram-positive and Gram-negative bacteria and are involved in the innate host defense of tears in protecting the ocular surface against microbial pathogens. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
Huang, Jing-Feng; Yafawi, Rolla; Zhang, Min; McDowell, Michael; Rittenhouse, Kay D; Sace, Frederick; Liew, Shiao Hui Melissa; Cooper, Scott R; Pickering, Eve H
2012-07-01
To evaluate the immunomodulatory effect of topical ophthalmic tofacitinib (CP-690,550) after an 8-week treatment period in patients with dry eye disease (DED). Biomarker substudy of a phase 1/2 prospective, randomized, vehicle- and comparator-controlled clinical trial (NCT00784719). A total of 82 patients with moderate to severe DED enrolled. Patients received 1 of 5 doses of tofacitinib (0.0003%, 0.001%, 0.003%, or 0.005% twice daily [BID] or 0.005% once daily [QD]), active comparator (cyclosporine ophthalmic emulsion, 0.05% [Restasis, Allergan Inc., Irvine, CA]), or vehicle control BID for 8 weeks. Conjunctival impression cytology and tear fluid samples were collected at baseline and after an 8-week treatment period. Conjunctival cells were analyzed by flow cytometry for human leukocyte antigen DR-1 (HLA-DR). Tear fluids were analyzed by microsphere-based immunoassays for tear levels of cytokines and inflammation markers. Reduction in inflammation assessed by change from baseline in conjunctival cell surface level of HLA-DR and tear level of cytokines and inflammation markers. At week 8, a decrease in conjunctival cell surface expression of HLA-DR was observed in patients treated with tofacitinib 0.005% QD and 0.003% BID: 71% and 67% of baseline, respectively, compared with 133% of baseline in patients treated with vehicle (P=0.023 and P=0.006, compared with vehicle, respectively). Matrix metalloproteinase (MMP)-3 in tears was reduced from baseline at week 8 (40% of baseline, P=0.035) in the tofacitinib 0.005% QD group, whereas the vehicle group showed 77% of baseline (P>0.20). Interleukin (IL)-1β in tears was 36% of baseline (P=0.053) in the tofacitinib 0.005% QD group and 95% of baseline (P > 0.20) in the vehicle group. Several other cytokines and inflammation markers in tears, including MMP-9, IL-15, IL-17A, and IL-12p70, were markedly reduced in the tofacitinib 0.005% QD group but not the vehicle group. There was an association between the changes in HLA-DR and the tear inflammation markers (P<0.05): HLA-DR with IL-12p70 (r=0.49) and IL-1β (r=0.46), IL-12p70 with IL-1β (r=0.90), and IL-17A with MMP-9 (r=0.82). Topical ophthalmic tofacitinib may act as an immunomodulator in patients with DED. Treatment for 8 weeks showed a promising reduction of conjunctival cell surface HLA-DR expression and tear levels of proinflammatory cytokines and inflammation markers. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Dry Eye Management: Targeting the Ocular Surface Microenvironment.
Zhang, Xiaobo; M, Vimalin Jeyalatha; Qu, Yangluowa; He, Xin; Ou, Shangkun; Bu, Jinghua; Jia, Changkai; Wang, Junqi; Wu, Han; Liu, Zuguo; Li, Wei
2017-06-29
Dry eye can damage the ocular surface and result in mild corneal epithelial defect to blinding corneal pannus formation and squamous metaplasia. Significant progress in the treatment of dry eye has been made in the last two decades; progressing from lubricating and hydrating the ocular surface with artificial tear to stimulating tear secretion; anti-inflammation and immune regulation. With the increase in knowledge regarding the pathophysiology of dry eye, we propose in this review the concept of ocular surface microenvironment. Various components of the microenvironment contribute to the homeostasis of ocular surface. Compromise in one or more components can result in homeostasis disruption of ocular surface leading to dry eye disease. Complete evaluation of the microenvironment component changes in dry eye patients will not only lead to appropriate diagnosis, but also guide in timely and effective clinical management. Successful treatment of dry eye should be aimed to restore the homeostasis of the ocular surface microenvironment.
Dry Eye Management: Targeting the Ocular Surface Microenvironment
Zhang, Xiaobo; Jeyalatha M, Vimalin; Qu, Yangluowa; He, Xin; Ou, Shangkun; Bu, Jinghua; Jia, Changkai; Wang, Junqi; Wu, Han; Liu, Zuguo
2017-01-01
Dry eye can damage the ocular surface and result in mild corneal epithelial defect to blinding corneal pannus formation and squamous metaplasia. Significant progress in the treatment of dry eye has been made in the last two decades; progressing from lubricating and hydrating the ocular surface with artificial tear to stimulating tear secretion; anti-inflammation and immune regulation. With the increase in knowledge regarding the pathophysiology of dry eye, we propose in this review the concept of ocular surface microenvironment. Various components of the microenvironment contribute to the homeostasis of ocular surface. Compromise in one or more components can result in homeostasis disruption of ocular surface leading to dry eye disease. Complete evaluation of the microenvironment component changes in dry eye patients will not only lead to appropriate diagnosis, but also guide in timely and effective clinical management. Successful treatment of dry eye should be aimed to restore the homeostasis of the ocular surface microenvironment. PMID:28661456
Therapeutic inhibitors for the treatment of dry eye syndrome.
Rodríguez-Pomar, Candela; Pintor, Jesus; Colligris, Basilio; Carracedo, Gonzalo
2017-12-01
Dry eye disease (DED), defined as a multifactorial disease of tears and ocular surface, results in symptoms of discomfort, ocular irritation, visual disturbance and tear film instability. This syndrome is accompanied of ocular surface inflammation and it is produced by a deficient activity of the lacrimal functional unit. In addition, it is associated with systemic autoimmune diseases such as Sjögren´s Syndrome, rheumatoid arthritis, systemic lupus erythematosus and some drug administration. The treatment of dry eye disease is based on the typical signs and symptoms of dry eye, which are associated with hyperosmolarity, ocular surface inflammation, discomfort, visual disturbance, and tear film instability. Areas covered: This review is focused on synthetic drugs currently used in clinical practice, from phase III development onwards to treat the ocular surface signs and symptoms of dry eye disease. Expert opinion: The multifactorial disease and the lack of correlation between signs and symptoms imply that not all the pharmacological approaches will be successful for dry eye. The correct design of the clinical trials, with appropriate endpoints, and the type of dry eye under study are complicated but mandatory. The anti-inflammatory and secretagogues drugs are both the main compounds to currently treat the dry eye disease.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goldberg, A.; Lesuer, D.R.; Patt, J.
Experimental results, together with an analytical model, related to the loss in tensile strength of styrene-butadiene rubber (SBR) loaded with carbon black (CB) that had been subjected to low-cycle, high-stress fatigue tests were presented in a prior paper. The drop in tensile strength relative to that of a virgin sample was considered to be a measure of damage induced during the fatigue test. The present paper is a continuation of this study dealing with the morphological interpretations of the fractured surfaces, whereby the cyclic-tearing behavior, resulting in the damage, is related to the test and material parameters. It was foundmore » that failure is almost always initiated in the bulk of a sample at a material flaw. The size and definition of a flaw increase with an increase in carbon-black loading. Initiation flaw sites are enveloped by fan-shaped or penny-shaped regions which develop during cycling. The size and morphology of a fatigue-tear region appears to be independent of the fatigue load or the extent of the damage (strength loss). By contrast, either an increase in cycling load or an increase in damage at constant load increases the definition of the fatigue-region morphology for all formulations of carbon-black. On the finest scale, the morphology can be described in terms of tearing of individual groups of rubber strands, collapsing to form a cell-like structure. 18 refs., 13 figs.« less
Kaido, Minako; Kawashima, Motoko; Ishida, Reiko; Tsubota, Kazuo
2016-03-01
The purpose of this prospective comparative study was to investigate corneal sensitivity in subjects with unstable tear film, with and without dry eye (DE) symptoms. Forty-one eyes of 41 volunteers (mean age: 45.1 ± 9.4 years; age range, 23-57 years), with normal tear function and ocular surface except for tear stability, were studied. The eyes were divided into two groups depending on the presence or absence of DE symptoms: 21 eyes with DE symptoms (symptomatic group); and 20 eyes without DE symptoms (asymptomatic group). Three types of corneal sensitivity values were measured using a Cochet-Bonnet esthesiometer: the sensitivity for perception of touch (S-touch), the sensitivity for blinking (S-blink), and the sensitivity for pain (S-pain). Mean S-blink and S-pain were significantly higher in the symptomatic group than in the asymptomatic group (P < 0.05), whereas there was no significant difference in mean S-touch between these groups (P > 0.05). Corneal sensitivity for blinking and pain evoked by increased stimuli was higher in the symptomatic group (subjects with short break-up time DE) compared with subjects who have no DE symptoms despite decreased tear stability. The presence of both tear instability and hyperesthesia, rather than tear instability alone, may contribute to DE pathogenesis.
Ipsilateral Medial and Lateral Discoid Meniscus with Medial Meniscus Tear
Shimozaki, Kengo; Nakase, Junsuke; Ohashi, Yoshinori; Numata, Hitoaki; Oshima, Takeshi; Takata, Yasushi; Tsuchiya, Hiroyuki
2016-01-01
Introduction: Discoid meniscus is a well-documented knee pathology, and there are many cases of medial or lateral discoid meniscus reported in the literature. However, ipsilateral concurrent medial and lateral discoid meniscus is very rare, and only a few cases have been reported. Herein, we report a case of concurrent medial and lateral discoid meniscus. Case Report: A 27-year-old Japanese man complained of pain on medial joint space in his right knee that was diagnosed as a complete medial and lateral discoid meniscus. In magnetic resonance imaging, although the lateral discoid meniscus had no tear, the medial discoid meniscus had a horizontal tear. Arthroscopic examination of his right knee similarly revealed that the medial discoid meniscus had a horizontal tear. In addition, the discoid medial meniscus also had an anomalous insertion to the anterior cruciate ligament, and there was also mild fibrillation of the medial tibial cartilage surface. We performed arthroscopic partial meniscectomy for the torn medial discoid meniscus but not for the asymptomatic lateral discoid meniscus. The latest follow-up at 18 months indicated satisfactory results. Conclusion: We report a rare case of ipsilateral medial and lateral discoid meniscus with medial meniscus tear. The medial discoid meniscus with tear was treated with partial meniscectomy, whereas the lateral discoid meniscus without tear was only followed up. PMID:28164045
NASA Astrophysics Data System (ADS)
Palano, M.; Piromallo, C.; Chiarabba, C.
2017-01-01
Dense GPS observations can help Earth scientists to capture the surface imprint of mantle toroidal flow at slab edges. We document this process in the Calabrian subduction system, where the Ionian slab rollback took place during the past 30 Ma, following a stepwise process driven by migration of lithospheric tearing. We found rotation rates of 1.29°/Ma (counterclockwise) and 1.74°/Ma (clockwise), for poles located close to the northern and southern slab edges, respectively. These small-scale, opposite rotations occur along complex sets of active faults representing the present-day lithospheric expression of the tearing processes affecting the southeastward retreating Ionian slab at both edges. The observed rotations are likely still young and the process more immature at the northern tear, where it is unable to reorient mantle fabric and therefore is unseen by SKS splitting.
Aristoteli, Lina Panayiota; Willcox, Mark D P
2006-11-01
Pseudomonas aeruginosa is a pathogen gaining prevalence in contact lens-related corneal ulcers. Tear outflow protects the ocular surface, where high molecular weight tear glycoproteins bind bacteria for removal from the eye. The purpose of the present study was to identify glycoproteins in human tears involved in the adhesion of ocular P. aeruginosa isolates. Basal human tears were applied to a bacterial adhesion assay involving electrophoretic separation of tear components, transfer to nitrocellulose and incubation with biotin-labelled bacteria. Glycoproteins were further characterised using lectin profiling. The results showed large-dimension agarose gels were imperative for the detection of at least four glycoproteins with a migration >200 kDa, including species not previously identified. P. aeruginosa 6294 preferentially bound to a well-defined glycoprotein near the origin of the gel that, unlike other glycoproteins >200 kDa, reacted with Sambucus nigra lectin (sialic acid alpha2-6) but not WGA lectin (N-acetylglucosamine, sialic acid alpha2-3). Adhesion did not involve free biotin label or hydrophobic interactions. Also, the pre-incubation of separated tear glycoproteins with S. nigra lectin increased subsequent adhesion of 6294 to this tear glycoprotein. The less virulent Paer1 strain showed diffuse adhesion in the S. nigra-reactive region at the gel origin. In conclusion, an overlay adhesion assay was developed that identified slow-migrating sialylated glycoprotein species in human tears preferentially bound by P. aeruginosa ocular strains, and S. nigra lectin seemed to enhance the interaction. The study provides a basis for direct investigation of bacterial adhesion to glycoproteins with an apparent migration >200 kDa in tear fluid.
Retinal tear presenting in a patient with ectrodactyly ectodermal dysplasia.
Grogg, Jane Ann; Port, Nicholas; Graham, Trevor
2014-04-01
This article aims to report a case of known ectrodactyly ectodermal dysplasia in a young male patient who subsequently was found to have a retinal tear and localized retinal detachment. This is a case report of a 22-year-old white male patient with a history of ectrodactyly ectodermal dysplasia. Our patient initially presented with an acute exacerbation of bilateral, red, irritated eyes. No recent changes in vision were reported. The patient's ocular surface disease was consistent with ectrodermal dysplasia syndrome. However, a dilated fundus examination revealed an asymptomatic retinal tear with a surrounding localized retinal detachment. In this case, the patient presented with longstanding ocular surface disease known to be associated with this patient's inherited ectoderm disorder. In addition, this patient revealed a retinal tear, raising the possibility that patients with inherited congenital ectodermal dysplasia could be at risk for damaged structures originating from the neural ectoderm. In this heterogeneous disease, we are contributing to the existing literature a case of ectodermal dysplasia syndrome with obvious ectodermal complications that also had retinal findings leading us to speculate question if neural ectoderm could also be involved in this inherited disease.
Dry Eye as a Mucosal Autoimmune Disease
Stern, Michael E.; Schaumburg, Chris S.; Pflugfelder, Stephen C.
2013-01-01
Dry eye is a common ocular surface inflammatory disease that significantly affects quality of life. Dysfunction of the lacrimal function unit (LFU) alters tear composition and breaks ocular surface homeostasis, facilitating chronic inflammation and tissue damage. Accordingly, the most effective treatments to date are geared towards reducing inflammation and restoring normal tear film. The pathogenic role of CD4+ T cells is well known, and the field is rapidly realizing the complexity of other innate and adaptive immune factors involved in the development and progression of disease. The data support the hypothesis that dry eye is a localized autoimmune disease originating from an imbalance in the protective immunoregulatory and proinflammatory pathways of the ocular surface. PMID:23360156
A Disposable Tear Glucose Biosensor—Part 1: Design and Concept Testing
Bishop, Daniel K.; La Belle, Jeffrey T.; Vossler, Stephen R.; Patel, Dharmendra R.; Cook, Curtiss B.
2010-01-01
Background Tear glucose has been suggested previously as a potential approach for the noninvasive estimation of blood glucose. While the topic remains unresolved, an overview of previous studies suggests the importance of a tear sampling approach and warrants new technology development. A concept device is presented that meets the needs of a tear glucose biosensor. Methods Three approaches to chronoamperometric glucose sensing were evaluated, including glucose oxidase mediated by potassium ferricyanide or oxygen with a hydrogen peroxide catalyst, Prussian blue, and potassium ferricyanide-mediated glucose dehydrogenase. For tear sampling, calcium alginate, poly(2-hydroxyethyl methacrylate), and polyurethane foam were screened as an absorbent tear sampling material. A quantitative model based on the proposed function of concept device was created. Results For glucose sensing, it was found that potassium ferricyanide with glucose dehydrogenase was ideal, featuring oxygen insensitivity, long-term stability, and a lower limit of detection of 2 μM glucose. Polyurethane foam possessed all of the required characteristics for tear sampling, including reproducible sampling from a hydrogel-simulated, eye surface (4.2 ± 0.5 μl; n = 8). It is estimated that 100 μM of glucose tear fluid would yield 135 nA (14.9% relative standard deviation). Conclusion A novel concept device for tear glucose sampling was presented, and the key functions of this device were tested and used to model the performance of the final device. Based on these promising initial results, the device is achievable and within reach of current technical capabilities, setting the stage for prototype development. PMID:20307389
Human tears reveal insights into corneal neovascularization.
Zakaria, Nadia; Van Grasdorff, Sigi; Wouters, Kristien; Rozema, Jos; Koppen, Carina; Lion, Eva; Cools, Nathalie; Berneman, Zwi; Tassignon, Marie-José
2012-01-01
Corneal neovascularization results from the encroachment of blood vessels from the surrounding conjunctiva onto the normally avascular cornea. The aim of this study is to identify factors in human tears that are involved in development and/or maintenance of corneal neovascularization in humans. This could allow development of diagnostic tools for monitoring corneal neovascularization and combination monoclonal antibody therapies for its treatment. In an observational case-control study we enrolled a total of 12 patients with corneal neovascularization and 10 healthy volunteers. Basal tears along with reflex tears from the inferior fornix, superior fornix and using a corneal bath were collected along with blood serum samples. From all patients, ocular surface photographs were taken. Concentrations of the pro-angiogenic cytokines interleukin (IL)-6, IL-8, Vascular Endothelial Growth Factor (VEGF), Monocyte Chemoattractant Protein 1 (MCP-1) and Fas Ligand (FasL) were determined in blood and tear samples using a flow cytometric multiplex assay. Our results show that the concentration of pro-angiogenic cytokines in human tears are significantly higher compared to their concentrations in serum, with highest levels found in basal tears. Interestingly, we could detect a significantly higher concentration of IL- 6, IL-8 and VEGF in localized corneal tears of patients with neovascularized corneas when compared to the control group. This is the first study of its kind demonstrating a significant difference of defined factors in tears from patients with neovascularized corneas as compared to healthy controls. These results provide the basis for future research using animal models to further substantiate the role of these cytokines in the establishment and maintenance of corneal neovascularization.
Human Tears Reveal Insights into Corneal Neovascularization
Wouters, Kristien; Rozema, Jos; Koppen, Carina; Lion, Eva; Cools, Nathalie; Berneman, Zwi; Tassignon, Marie-José
2012-01-01
Corneal neovascularization results from the encroachment of blood vessels from the surrounding conjunctiva onto the normally avascular cornea. The aim of this study is to identify factors in human tears that are involved in development and/or maintenance of corneal neovascularization in humans. This could allow development of diagnostic tools for monitoring corneal neovascularization and combination monoclonal antibody therapies for its treatment. In an observational case-control study we enrolled a total of 12 patients with corneal neovascularization and 10 healthy volunteers. Basal tears along with reflex tears from the inferior fornix, superior fornix and using a corneal bath were collected along with blood serum samples. From all patients, ocular surface photographs were taken. Concentrations of the pro-angiogenic cytokines interleukin (IL)-6, IL-8, Vascular Endothelial Growth Factor (VEGF), Monocyte Chemoattractant Protein 1 (MCP-1) and Fas Ligand (FasL) were determined in blood and tear samples using a flow cytometric multiplex assay. Our results show that the concentration of pro-angiogenic cytokines in human tears are significantly higher compared to their concentrations in serum, with highest levels found in basal tears. Interestingly, we could detect a significantly higher concentration of IL- 6, IL-8 and VEGF in localized corneal tears of patients with neovascularized corneas when compared to the control group. This is the first study of its kind demonstrating a significant difference of defined factors in tears from patients with neovascularized corneas as compared to healthy controls. These results provide the basis for future research using animal models to further substantiate the role of these cytokines in the establishment and maintenance of corneal neovascularization. PMID:22590547
Turhan, Semra Akkaya; Toker, Ebru
2015-01-01
To evaluate the lens edge interaction with the ocular surface with different edge designs using optical coherence tomography and to examine the effect of lens power on the lens edge interactions. Four types of silicone hydrogel lenses with different edge designs (round-, semi-round-, chisel-, and knife-edged) at six different powers (+5.0, +3.0, +1.0, -1.0, -3.0, and -5.0 diopters) were fitted to both eyes of 20 healthy volunteers. Optical coherence tomography images were taken at the corneal center and at the limbus within 15-30 minutes after insertion. The images were evaluated with respect to two parameters: conjunctival indentation exerted by the lens edge; and the tear film gaps between the posterior surface of the lens and the ocular surface. The amount of conjunctival indentation was measured with the distortion angle of the conjunctiva at the lens edge. The degree of conjunctival indentation was highest with the chisel-edged design followed by the semi-round design (P<0.0001). Knife- and round-edged lenses exerted similar levels of conjunctival indentation that was significantly lower compared to chisel-edged lens (P<0.001). For each one of the tested lens edge designs, no significant difference was observed in the conjunctival indentation with respect to lens power. The chisel-edged lens produced the highest amount of conjunctival indentation for each one of the six lens powers (P<0.0001). Post-lens tear film gaps at the limbus were observed at most in the round-edge design (P=0.001). The fitting properties of contact lenses may be influenced by their edge design but not by their lens power.
Turhan, Semra Akkaya; Toker, Ebru
2015-01-01
Purpose To evaluate the lens edge interaction with the ocular surface with different edge designs using optical coherence tomography and to examine the effect of lens power on the lens edge interactions. Methods Four types of silicone hydrogel lenses with different edge designs (round-, semi-round-, chisel-, and knife-edged) at six different powers (+5.0, +3.0, +1.0, −1.0, −3.0, and −5.0 diopters) were fitted to both eyes of 20 healthy volunteers. Optical coherence tomography images were taken at the corneal center and at the limbus within 15–30 minutes after insertion. The images were evaluated with respect to two parameters: conjunctival indentation exerted by the lens edge; and the tear film gaps between the posterior surface of the lens and the ocular surface. The amount of conjunctival indentation was measured with the distortion angle of the conjunctiva at the lens edge. Results The degree of conjunctival indentation was highest with the chisel-edged design followed by the semi-round design (P<0.0001). Knife- and round-edged lenses exerted similar levels of conjunctival indentation that was significantly lower compared to chisel-edged lens (P<0.001). For each one of the tested lens edge designs, no significant difference was observed in the conjunctival indentation with respect to lens power. The chisel-edged lens produced the highest amount of conjunctival indentation for each one of the six lens powers (P<0.0001). Post-lens tear film gaps at the limbus were observed at most in the round-edge design (P=0.001). Conclusion The fitting properties of contact lenses may be influenced by their edge design but not by their lens power. PMID:26045658
[New approaches to the treatment of keratoconjunctivitis sicca].
Safonova, T N; Gladkova, O V; Novikov, I A; Boev, V I; Fedorov, A A
A new method has been developed for the treatment of severe forms of keratoconjunctivitis sicca (KCS) that involves the use of an original cyclosporine A (CyA) saturated soft contact lens (SCL) together with preservative-free artificial tears therapy. to evaluate the effectiveness of the newly developed treatment for KCS based on the use of medical SCL saturated with 0.05% CyA. The patients (43 men, 60 eyes) with severe KCS were divided into 2 groups. Group 1 included 21 patients (30 eyes), who received artificial tears and wore 0.05% CyA-saturated silicone-hydrogel SCLs. Group 2 included 22 patients (30 eyes), who wore unsaturated original SCLs and received CyA instillations 2 times daily and, also, artificial tears. Apart from a standard ophthalmic examination, the assessment included Schirmer's test, Norn's test, vital eye stain tests, tear osmometry, laser confocal tomography of the cornea, optical coherence tomography of the anterior segment with meniscometry, impression cytology of the conjunctiva, tear pH measurement, plating of the content of the conjunctival cavity, measurement of the width of the palpebral fissure, and calculation of the ocular surface disease index. Treatment results were followed up at 1, 3, 6, and 12 months. The use of 0.05% CyA-saturated SCLs allows to halve treatment time for patients with severe KSC (down to 1 week - 1 month) as compared to unsaturated original SCLs in combination with 0.05% CyA instillations and to reduce it 5 times as compared to 0.05% CyA instillations only. The new method of KSC treatment that involves the use of medical SCL of original design (ensures even distribution of 0.05% CyA across the ocular surface) and preservative-free artificial tears has demonstrated high therapeutic effectiveness as compared to existing methods.
Surface interactions on hydrogel contact lenses: scanning electron microscopy (SEM).
Hart, D E
1987-12-01
SEM was used to visualize tear-film/hydrogel polymer surface interactions. Lenses were preserved by fixation including a quaternary ammonium complex to aid in mucin preservation. In less than 2 weeks of continuous wear the anterior surface was completely coated, yet the coating was absent from the posterior lens surface. Tear-film break-up over the deposited lens surface, combined with degradation and deformation at the polymer surface boundary, as well as entrapment of moieties within the polymer matrix, all occurred. These are the likely culprits which can contribute to adverse reactions as well as cause light scatter and diminished vision. Lenses removed directly from the eyes of patients suffering with different forms of conjunctivitis were obtained. Bacterial and viral conjunctivitis can induce a microbially contaminated as well as a heavily deformed and deposited lens. Viable and intact microbes were not typically observed in the mucoprotein layer of hydrogel contact lenses.
Jain, Pooja; Li, Ruihong; Lama, Teresa; Saragovi, H Uri; Cumberlidge, Garth; Meerovitch, Karen
2011-10-01
The aim of this study was to evaluate the efficacy of MIM-D3, a small molecule nerve growth factor (NGF) peptidomimetic, as a therapeutic agent in rats with scopolamine induced dry eye. NGF plays an important role in ocular surface maintenance and corneal wound healing and was recently shown to have mucin secretagogue activity in conjunctival cells. We investigated whether MIM-D3 increased glycoconjugate secretion in conjunctival cells in vitro and in rat tear fluids in vivo. Primary rat conjunctival cell cultures were treated with increasing concentrations of MIM-D3 and evaluated for glycoconjugate secretion, proliferation and MAPK1/2 activation. Glycoconjugates were quantitated in tear fluids from normal rats treated topically with increasing doses of MIM-D3 (0.4%, 1% and 2.5%). Dry eye was induced in rats by subcutaneous scopolamine treatment, administered by surgically implanted osmotic pumps for 14 or 28 days. Aqueous tear production, tear clearance, fluorescein corneal staining and tear break-up time (tBUT) were evaluated. Glycoconjugates and NGF were quantitated in the tear fluids by enzyme-linked lectin assay (ELLA) and enzyme-linked immunosorbant assay (ELISA), respectively. We found that 50 μM MIM-D3 statistically significantly induced a 1.3-fold increase in glycoconjugate secretion and a 2.3-fold increase in MAPK1/2 activation without increasing proliferation from conjunctival cell cultures. Application of 2.5% MIM-D3 in normal rat eyes statistically significantly increased tear glycoconjugate concentration by 2.3-fold. In the experimental dry eye model, application of 1% MIM-D3 to rat eyes for either 1 or 17 consecutive days, followed by 1 week of no dosing produced a statistically significant decrease in corneal staining (p < 0.001), a slight increase in tBUT, and increases in tear glycoconjugates (p < 0.05) compared to vehicle. Scopolamine treatment also caused a statistically significant increase of endogenous NGF in tears (p < 0.005). We concluded that the increase in glycoconjugate concentration by the 1% MIM-D3 dose may have improved the quality and stability of the tear film, and thereby improved healing on the ocular surface in dry eye. Therefore, MIM-D3 may have therapeutic potential as a topical agent for the treatment of dry eye. Copyright © 2011 Elsevier Ltd. All rights reserved.
A novel capsulorhexis technique using shearing forces with cystotome.
Karim, Shah M R; Ong, Chin T; Sleep, Tamsin J
2010-05-15
To demonstrate a capsulorhexis technique using predominantly shearing forces with a cystotome on a virtual reality simulator and on a human eye. Our technique involves creating the initial anterior capsular tear with a cystotome to raise a flap. The flap left unfolded on the lens surface. The cystotome tip is tilted horizontally and is engaged on the flap near the leading edge of the tear. The cystotome is moved in a circular fashion to direct the vector forces. The loose flap is constantly swept towards the centre so that it does not obscure the view on the tearing edge. Our technique has the advantage of reducing corneal wound distortion and subsequent anterior chamber collapse. The capsulorhexis flap is moved away from the tear leading edge allowing better visualisation of the direction of tear. This technique offers superior control of the capsulorhexis by allowing the surgeon to change the direction of the tear to achieve the desired capsulorhexis size. The EYESI Surgical Simulator is a realistic training platform for surgeons to practice complex capsulorhexis techniques. The shearing forces technique is a suitable alternative and in some cases a far better technique in achieving the desired capsulorhexis.
Determination of loss tangent of human tear film at 9.8 GHz
NASA Astrophysics Data System (ADS)
Bansal, Namita; Dhaliwal, A. S.; Mann, K. S.
2015-08-01
Basal (non-stimulated) tears that are produced by accessory lacrimal glands located in conjunctiva of human eye, form tear film which in turn keeps the eye moist and lubricate; nourishes the eye; protects the eye from dust, bacterial infection and shear forces generated during eye movements and blinking; and provides a refractive surface on the corneal epithelium. Film is known to contain water, mucin, lipids, lysozyme, glucose, urea, sodium etc. In present communication, loss tangent of human tear film has been determined at 9.8 GHz microwaves by employing cavity perturbation technique at a temperature of 37°C. The basal tears from a small population comprising six subjects were collected and average value of loss tangent is reported. Slater's technique was used to reduce the error caused in measuring the volume of sample. The determined values are useful to study the biological effects of microwaves on tear film as well as other parts of human eye such as eye lens and lens epithelial cells. To the best of author's knowledge, no such study is available in literature at any radio as well as microwave frequencies; therefore present determinations are first of its kind.
Organization of Lipids in the Tear Film: A Molecular-Level View
Wizert, Alicja; Iskander, D. Robert; Cwiklik, Lukasz
2014-01-01
Biophysical properties of the tear film lipid layer are studied at the molecular level employing coarse grain molecular dynamics (MD) simulations with a realistic model of the human tear film. In this model, polar lipids are chosen to reflect the current knowledge on the lipidome of the tear film whereas typical Meibomian-origin lipids are included in the thick non-polar lipids subphase. Simulation conditions mimic those experienced by the real human tear film during blinks. Namely, thermodynamic equilibrium simulations at different lateral compressions are performed to model varying surface pressure, and the dynamics of the system during a blink is studied by non-equilibrium MD simulations. Polar lipids separate their non-polar counterparts from water by forming a monomolecular layer whereas the non-polar molecules establish a thick outermost lipid layer. Under lateral compression, the polar layer undulates and a sorting of polar lipids occurs. Moreover, formation of three-dimensional aggregates of polar lipids in both non-polar and water subphases is observed. We suggest that these three-dimensional structures are abundant under dynamic conditions caused by the action of eye lids and that they act as reservoirs of polar lipids, thus increasing stability of the tear film. PMID:24651175
Tsubota, Kazuo; Yokoi, Norihiko; Shimazaki, Jun; Watanabe, Hitoshi; Dogru, Murat; Yamada, Masakazu; Kinoshita, Shigeru; Kim, Hyo-Myung; Tchah, Hung-Won; Hyon, Joon Young; Yoon, Kyung-Chul; Seo, Kyoung Yul; Sun, Xuguang; Chen, Wei; Liang, Lingyi; Li, Mingwu; Liu, Zuguo
2017-01-01
For the last 20 years, a great amount of evidence has accumulated through epidemiological studies that most of the dry eye disease encountered in daily life, especially in video display terminal (VDT) workers, involves short tear film breakup time (TFBUT) type dry eye, a category characterized by severe symptoms but minimal clinical signs other than short TFBUT. An unstable tear film also affects the visual function, possibly due to the increase of higher order aberrations. Based on the change in the understanding of the types, symptoms, and signs of dry eye disease, the Asia Dry Eye Society agreed to the following definition of dry eye: "Dry eye is a multifactorial disease characterized by unstable tear film causing a variety of symptoms and/or visual impairment, potentially accompanied by ocular surface damage." The definition stresses instability of the tear film as well as the importance of visual impairment, highlighting an essential role for TFBUT assessment. This paper discusses the concept of Tear Film Oriented Therapy (TFOT), which evolved from the definition of dry eye, emphasizing the importance of a stable tear film. Copyright © 2016 The Author(s). Published by Elsevier Inc. All rights reserved.
Herok, George Henryk; Mudgil, Poonam; Millar, Thomas James
2009-07-01
The lipid layer of the tear film is associated with preventing evaporative loss. The ability of human Meibomian lipids to reduce evaporation in vitro was tested. Films of human or animal Meibomian lipids or mixtures of cholesterol and phosphatidylcholine were spread on the surface of either artificial buffer or on whole tears and placed on a mass balance that was enclosed in a sealed chamber. The temperature was adjusted to 37 degrees C and gas flow was controlled. Increasing the amounts of Meibomian lipids gave a very small reduction in evaporation. It was concluded from these in vitro experiments that prevention of evaporation from the tear film is not due to the Meibomian lipids alone, but is more likely to be due to a complex interaction between components of the aqueous and the Meibomian lipids.
Deinema, Laura A; Vingrys, Algis J; Wong, Chinn Yi; Jackson, David C; Chinnery, Holly R; Downie, Laura E
2017-01-01
To assess the efficacy of 2 forms of oral long-chain omega-3 (ω-3) essential fatty acid (EFA) supplements, phospholipid (krill oil) and triacylglyceride (fish oil), for treating dry eye disease (DED). Randomized, double-masked, placebo-controlled clinical trial. This study was conducted at a single site and involved 60 participants with mild to moderate DED who were randomized (1:1:1) to 1 of 3 groups: placebo (olive oil), krill oil, or fish oil supplements. Participants received 1 of the 3 interventions: placebo (olive oil 1500 mg/day), krill oil (945 mg/day eicosapentaenoic acid [EPA], + 510 mg/day docosahexaenoic acid [DHA]), or fish oil (1000 mg/day EPA + 500 mg/day DHA) for 90 days, with monthly study visits. Primary outcome measures were mean change in (1) tear osmolarity and (2) DED symptoms (Ocular Surface Disease Index [OSDI] score) between days 1 and 90. Secondary outcomes included mean change in key clinical signs (tear stability, tear production, ocular surface staining, bulbar and limbal redness, tear volume, anterior blepharitis, meibomian gland capping) and tear inflammatory cytokine levels. In total, 54 participants completed the study. At day 90, tear osmolarity was reduced from baseline with both krill oil (mean ± standard error of the mean: -18.6±4.5 mOsmol/l; n = 18; P < 0.001) and fish oil (-19.8±3.9 mOsmol/l; n = 19; P < 0.001) supplements, compared with placebo (-1.5±4.4 mOsmol/l; n = 17). OSDI score was significantly reduced at day 90 relative to baseline in the krill oil group only, compared with placebo (-18.6±2.4 vs. -10.5±3.3; P = 0.02). At day 90, there were also relative improvements in tear breakup time and ocular bulbar redness, compared with placebo, for both forms of ω-3 EFAs. Basal tear levels of the proinflammatory cytokine interleukin 17A were significantly reduced in the krill oil group, compared with placebo, at day 90 (-27.1±10.9 vs. 46.5±30.4 pg/ml; P = 0.02). A moderate daily dose of both forms of long-chain ω-3 EFAs, for 3 months, resulted in reduced tear osmolarity and increased tear stability in people with DED. Omega-3 EFAs in a predominantly phospholipid form (krill oil) may confer additional therapeutic benefit, with improvements in DED symptoms and lower basal tear levels of interleukin 17A, relative to placebo. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Effect of benzalkonium chloride on the stability of the precorneal tear film in rabbit and man.
Wilson, W. S.; Duncan, A. J.; Jay, J. L.
1975-01-01
Benzalkonium chloride, a surface-active preservative commonly used in eyedrop preparations, has been shown to hasten the drying of the precorneal tear film. In the rabbit, 0.01 per cent benzalkonium (the concentration usually employed as a preservative) shortened the time required for the appearance of dry spots on the corneal surface by a factor of about four. In man, an approximately twofold hastening was demonstrated. This effect is thought to preclude the use of this substance as a preservative in eyedrop preparations for use as local anaesthetics. PMID:1203224
Modeling corneal surfaces with rational functions for high-speed videokeratoscopy data compression.
Schneider, Martin; Iskander, D Robert; Collins, Michael J
2009-02-01
High-speed videokeratoscopy is an emerging technique that enables study of the corneal surface and tear-film dynamics. Unlike its static predecessor, this new technique results in a very large amount of digital data for which storage needs become significant. We aimed to design a compression technique that would use mathematical functions to parsimoniously fit corneal surface data with a minimum number of coefficients. Since the Zernike polynomial functions that have been traditionally used for modeling corneal surfaces may not necessarily correctly represent given corneal surface data in terms of its optical performance, we introduced the concept of Zernike polynomial-based rational functions. Modeling optimality criteria were employed in terms of both the rms surface error as well as the point spread function cross-correlation. The parameters of approximations were estimated using a nonlinear least-squares procedure based on the Levenberg-Marquardt algorithm. A large number of retrospective videokeratoscopic measurements were used to evaluate the performance of the proposed rational-function-based modeling approach. The results indicate that the rational functions almost always outperform the traditional Zernike polynomial approximations with the same number of coefficients.
Comparison of camel tear proteins between summer and winter
Chen, Ziyan; Shamsi, Farrukh A.; Li, Kaijun; Huang, Qiang; Al-Rajhi, Ali A.; Chaudhry, Imtiaz A.
2011-01-01
Purpose Proteins in the tear fluid have positive effects on maintaining the integrity and stabilization of the tear film, which is affected by several environmental factors. The aim of this study is to investigate seasonal variation of protein patterns in camel tears collected during the summer and winter season. Methods Tears from both eyes of 50 clinically normal camels (Camelus dromedarius) were collected in the summer (June – July) and in the winter (December – January) respectively. Pooled tear protein samples from two seasons were separated by SDS–PAGE and two-dimensional electrophoresis (2-DE). Protein spots of differential expression in two season gels were excised and subjected to in-gel digestion and identification by matrix assisted laser desorption/ionization-time of flight/time of flight-mass spectrum (MALDI-TOF/TOF-MS) analysis. Two differentially expressed proteins, lactoferrin (LF) and vitelline membrane outer layer protein 1 homolog (VMO1 homolog), were validated by western blotting. Results Thirteen well resolved bands were detected in SDS–PAGE gels of both summer and winter camel tears. By band densitometry, significantly higher intensities of band 6, 7, 11, and lower intensity of band 13 were observed in the summer group compared to the winter group. In 2-DE profiles of camel tears, four protein spots were found expressed differentially in two seasons. Further protein identification by MALDI-TOF/TOF-MS and confirmation by western blotting indicated that there was a significant decrease in LF (p=0.002) and an increase in VMO1 homolog (p=0.042) in tears in the summer compared to the winter. Conclusions The seasonal variation of camel tear fluids has been found in the composition of proteins, including LF and VMO1 homolog. This result will expand our knowledge of physiologic characteristics of tear fluids and establish a foundation for the mechanistic studies and clinical practices on ocular surface disorders. PMID:21293736
Lipid order, saturation and surface property relationships: a study of human meibum saturation.
Mudgil, Poonam; Borchman, Douglas; Yappert, Marta C; Duran, Diana; Cox, Gregory W; Smith, Ryan J; Bhola, Rahul; Dennis, Gary R; Whitehall, John S
2013-11-01
Tear film stability decreases with age however the cause(s) of the instability are speculative. Perhaps the more saturated meibum from infants may contribute to tear film stability. The meibum lipid phase transition temperature and lipid hydrocarbon chain order at physiological temperature (33 °C) decrease with increasing age. It is reasonable that stronger lipid-lipid interactions could stabilize the tear film since these interactions must be broken for tear break up to occur. In this study, meibum from a pool of adult donors was saturated catalytically. The influence of saturation on meibum hydrocarbon chain order was determined by infrared spectroscopy. Meibum is in an anhydrous state in the meibomian glands and on the surface of the eyelid. The influence of saturation on the surface properties of meibum was determined using Langmuir trough technology. Saturation of native human meibum did not change the minimum or maximum values of hydrocarbon chain order so at temperatures far above or below the phase transition of human meibum, saturation does not play a role in ordering or disordering the lipid hydrocarbon chains. Saturation did increase the phase transition temperature in human meibum by over 20 °C, a relatively high amount. Surface pressure-area studies showing the late take off and higher maximum surface pressure of saturated meibum compared to native meibum suggest that the saturated meibum film is quite molecularly ordered (stiff molecular arrangement) and elastic (molecules are able to rearrange during compression and expansion) compared with native meibum films which are more fluid agreeing with the infrared spectroscopic results of this study. In saturated meibum, the formation of compacted ordered islands of lipids above the surfactant layer would be expected to decrease the rate of evaporation compared to fluid and more loosely packed native meibum. Higher surface pressure observed with films of saturated meibum compared to native meibum suggests greater film stability especially under the high shear stress of a blink. Copyright © 2013 Elsevier Ltd. All rights reserved.
Surgical treatment of dry eye syndrome: conjunctival graft of the minor salivary gland.
Güerrissi, Jorge Orlando; Belmonte, Javier
2004-01-01
Despite the availability of efficient tear substitutes, many patients with dry eye syndrome experience severe corneal injuries and a subsequent loss of vision. Surgical techniques using mayor salivary glands to provide a substitute for tears have been reported; with this technique the drainage of saliva goes into the conjunctival fornix, permitting corneal and conjunctival humidification. The authors describe a new surgical approach in which minor salivary glands are autotransplanted into the conjunctival fornix by means of a graft of the intraoral mucosa-transporting salivary glands. This approach was used in a 56-year-old woman with a 2-year history of refractory and pharmacologically untreatable dry eye syndrome caused by Sjögren's syndrome. The right eye had more severe corneal and conjunctival lesions than did the contralateral one, so the treatment was planned in the right eye only. A weekly follow-up during the first 6 months confirmed the significant improvement of dry eye symptoms in the surgically treated eye. Three months after surgery, a biopsy was performed in the minor salivary gland graft, and the histologic findings revealed the presence of glandular acinus, duct with mucin content, and lymphocyte infiltration. The significant improvement obtained in this patient suggests that the secretion from the grafted salivary minor glands was better in promoting homeostasis of the ocular surface than are artificial tears. This may be explained by: (1) The lacrimal and salivary secretions contain biologically active constituents that may protect from infection and promote normal growth epithelium; (2) The secreted mucin is thought to coat the epithelial surface, reducing the high surface tension of the eye wetted by aqueous tears; (3) The thick secretions of the minor gland might act in reducing the evaporation of the underlying tear layer and form a hydrophobic barrier along the lid margin that can retain the lid margin tear string and prevent its flow onto the skin. Minor gland salivary autotransplant is a new surgical technique with effectiveness demonstrated in one patient, but the scientific explanation is not clear; additional experience with more cases could confirm the initial success.
Kim, Yung Hui; Kang, Yeon Soo; Lee, Hyo Seok; Choi, Won; You, In Cheon; Yoon, Kyung Chul
2017-10-01
The aim of this study was to evaluate the effectiveness of combined tear film therapy targeted to aqueous, mucin, and lipid layers in patients with refractory evaporative dry eye (EDE) with short tear film breakup time (TBUT). The patients who had EDE with short TBUT and severe symptoms refractory to artificial tears were treated with hyaluronic acid (HA) 0.15% and diquafosol tetrasodium (DQS) 3% (Group 1), HA and carbomer-based lipid-containing eyedrops (Liposic EDO Gel, LPO) (Group 2), or HA, DQS, and LPO (Group 3). Ocular Surface Disease Index (OSDI) score, visual analog scale (VAS) symptom score, TBUT, Schirmer score, and corneal and conjunctival staining scores were evaluated, and noninvasive tear film breakup time (NIBUT) and tear meniscus height were measured using Keratograph ® 5 M before and 1 and 3 months after treatment. OSDI scores, VAS scores, TBUT, and NIBUT were improved at 1 and 3 months after treatment in all groups (all P < 0.05). At each follow-up visit, the total OSDI, OSDI symptom, and all VAS scores were significantly lower in group 3 compared with groups 1 and 2 (all P < 0.05). In addition, TBUT and NIBUT were significantly higher in group 3 compared with groups 1 and 2 (all P < 0.05). No significant adverse effects were noted in the groups during treatment. Mucin or lipid-targeting agents combined with aqueous supplements in patients with refractory EDE with short TBUT might improve subjective symptoms and TBUT. Of this, targeting whole tear film layers was most effective in improving ocular symptoms and tear film quality.
Relationship of individual scapular anatomy and degenerative rotator cuff tears.
Moor, Beat K; Wieser, Karl; Slankamenac, Ksenija; Gerber, Christian; Bouaicha, Samy
2014-04-01
The etiology of rotator cuff disease is age related, as documented by prevalence data. Despite conflicting results, growing evidence suggests that distinct scapular morphologies may accelerate the underlying degenerative process. The purpose of the present study was to evaluate the predictive power of 5 commonly used radiologic parameters of scapular morphology to discriminate between patients with intact rotator cuff tendons and those with torn rotator cuff tendons. A pre hoc power analysis was performed to determine the sample size. Two independent readers measured the acromion index, lateral acromion angle, and critical shoulder angle on standardized anteroposterior radiographs. In addition, the acromial morphology according to Bigliani and the acromial slope were determined on true outlet views. Measurements were performed in 51 consecutive patients with documented degenerative rotator cuff tears and in an age- and sex-matched control group of 51 patients with intact rotator cuff tendons. Receiver operating characteristic analyses were performed to determine cutoff values and to assess the sensitivity and specificity of each parameter. Patients with degenerative rotator cuff tears demonstrated significantly higher acromion indices, smaller lateral acromion angles, and larger critical shoulder angles than patients with intact rotator cuffs. However, no difference was found between the acromial morphology according to Bigliani and the acromial slope. With an area under the receiver operating characteristic curve of 0.855 and an odds ratio of 10.8, the critical shoulder angle represented the strongest predictor for the presence of a rotator cuff tear. The acromion index, lateral acromion angle, and critical shoulder angle accurately predict the presence of degenerative rotator cuff tears. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Post-lens tear turbidity and visual quality after scleral lens wear.
Carracedo, Gonzalo; Serramito-Blanco, Maria; Martin-Gil, Alba; Wang, Zicheng; Rodriguez-Pomar, Candela; Pintor, Jesús
2017-11-01
The aim was to evaluate the turbidity and thickness of the post-lens tear layer and its effect on visual quality in patients with keratoconus after the beginning of lens wear and before lens removal at the end of eight hours. Twenty-six patients with keratoconus (aged 36.95 ± 8.95 years) participated voluntarily in the study. The sample was divided into two groups: patients with intrastromal corneal ring (ICRS group) and patients without ICRS (KC group). Distance visual acuity (VA), contrast sensitivity, pachymetry, post-lens tear layer height and post-lens tear layer turbidity (percentage area occupied and number of particles per mm 2 ) were evaluated with optical coherence tomography before and after wearing a scleral lens. A significant increase of turbidity was found in all groups assessed (p < 0.05). The number of particles per square millimetre was eight times higher after scleral lens wear than at the beginning of wearing the lens for all groups. VA decreases in all groups after scleral lens wear (p < 0.001). All patients showed a statistical diminishing of contrast sensitivity after scleral lens wear (p < 0.05). A significant correlation was found for both turbidity parameters with distance VA but no correlation between turbidity and post-lens tear layer thickness at the beginning was found (p > 0.05). A strong correlation in all groups between the post-lens tear layer at the beginning and differences of tear layer thickness between two measures was also found (p < 0.05). The VA decrease during the scleral lens wearing, filled with preserved saline solution, was due to the increasing post-lens tear layer turbidity. © 2017 Optometry Australia.
Tear fluid collection in dogs and cats using ophthalmic sponges.
Sebbag, Lionel; Harrington, Danielle M; Mochel, Jonathan P
2018-05-01
To compare the use of two ophthalmic sponges for tear collection in dogs and cats. Ten healthy dogs and 10 healthy cats. A strip (4 × 10 mm) of either cellulose or polyvinyl acetal (PVA) sponge was inserted into the ventral fornix of each eye for either 15, 30, or 60 s. The wetted strip was placed into a 0.2-mL tube that was first punctured at its bottom. Tears were eluted through the drainage hole into a 1.5-mL tube via centrifugation. Tear volume absorbed (VA) and tear volume recovered (VR) were calculated as the difference of the post- and precollection weight of the 0.2-mL tube and 1.5-mL tube, respectively. Recovery ratio (RR) was determined as the ratio between VR and VA. Ophthalmic sponges were well tolerated by all subjects. In dogs and cats, median (95% range) VA, VR, and RR were as follows: 44 μL (11-106 μL) and 16 μL (2-43 μL); 27 μL (1-84 μL) and 6 μL (0-29 μL); 64% (7-91%) and 35% (0-86%), respectively. PVA sponges achieved significantly greater VR in cats and RR in both species. All parameters were significantly greater with a collection time of 60 vs. 30 and 15 s. Body weight was associated with VA and VR in dogs but not cats. Polyvinyl acetal is better than cellulose for tear collection given its superior recovery. Ophthalmic sponges could facilitate routine analysis of tear fluid in dogs and cats, although further studies are needed to evaluate the quality of tears obtained with this method. © 2017 American College of Veterinary Ophthalmologists.
Surface Chemistry Interactions of Cationorm with Films by Human Meibum and Tear Film Compounds
Georgiev, Georgi As.; Yokoi, Norihiko; Nencheva, Yana; Peev, Nikola; Daull, Philippe
2017-01-01
Cationorm® (CN) cationic nanoemulsion was demonstrated to enhance tear film (TF) stability in vivo possibly via effects on tear film lipid layer (TFLL). Therefore the interactions of CN with human meibum (MGS) and TFLL in vitro and in vivo deserve special study. MGS and CN were spread at the air/water interface of a Langmuir surface balance to ensure a range of MGS/CN oil phase ratios: 20/1, 10/1, 5/1, 3/1, 2/1 and 1/1. The films capability to reorganize during dynamic area changes was evaluated via the surface pressure-area compression isotherms and step/relaxation dilatational rheology studies. Films structure was monitored with Brewster angle microscopy. CN/TFLL interactions at the ocular surface were monitored with non-contact specular microscopy. The in vitro studies of MGS/CN layers showed that (i) CN inclusion (at fixed MGS content) increased film elasticity and thickness and that (ii) CN can compensate for moderate meibum deficiency in MGS/CN films. In vivo CN mixed with TFLL in a manner similar to CN/MGS interactions in vitro, and resulted in enhanced thickness of TFLL. In vitro and in vivo data complement each other and facilitated the study of the composition-structure-function relationship that determines the impact of cationic nanoemulsions on TF. PMID:28718823
Influence of interfacial rheology on stabilization of the tear film
NASA Astrophysics Data System (ADS)
Bhamla, M. Saad; Fuller, Gerald G.
2014-11-01
The tear film that protecting the ocular surface is a complex, thin film comprised of a collection of proteins and lipids that come together to provide a number of important functions. Of particular interest in this presentation is meibum, an insoluble layer that is spread from glands lining our eyelids. Past work has focussed on the role of this layer in reducing evaporation, although conflicting evidence on its ability to reduce evaporative loss has been published. We present here the beneficial effects that are derived through the interfacial viscoelasticity of the meibomian lipid film. This is a duplex film is comprised of a rich mixture of phospholipids, long chain fatty esters, and cholesterol esters. Using interfacial rheology measurements, meibum has been shown to be highly viscoelastic. By measuring the drainage and dewetting dynamics of thin aqueous films from hemispherical surfaces where those films are laden with insoluble layers of lipids at controlled surface pressure, we offer evidence that these layers strongly stabilize the films because of their ability to support surface shearing stresses. This alternative view of the role of meibum can help explain the origin of meibomian gland dysfunction, or dry eye disease, where improper compositions of this lipid mixture do not offer the proper mechanical resistance to breakage and dewetting of the tear film.
Inferring speaker attributes in adductor spasmodic dysphonia: ratings from unfamiliar listeners.
Isetti, Derek; Xuereb, Linnea; Eadie, Tanya L
2014-05-01
To determine whether unfamiliar listeners' perceptions of speakers with adductor spasmodic dysphonia (ADSD) differ from control speakers on the parameters of relative age, confidence, tearfulness, and vocal effort and are related to speaker-rated vocal effort or voice-specific quality of life. Twenty speakers with ADSD (including 6 speakers with ADSD plus tremor) and 20 age- and sex-matched controls provided speech recordings, completed a voice-specific quality-of-life instrument (Voice Handicap Index; Jacobson et al., 1997), and rated their own vocal effort. Twenty listeners evaluated speech samples for relative age, confidence, tearfulness, and vocal effort using rating scales. Listeners judged speakers with ADSD as sounding significantly older, less confident, more tearful, and more effortful than control speakers (p < .01). Increased vocal effort was strongly associated with decreased speaker confidence (rs = .88-.89) and sounding more tearful (rs = .83-.85). Self-rated speaker effort was moderately related (rs = .45-.52) to listener impressions. Listeners' perceptions of confidence and tearfulness were also moderately associated with higher Voice Handicap Index scores (rs = .65-.70). Unfamiliar listeners judge speakers with ADSD more negatively than control speakers, with judgments extending beyond typical clinical measures. The results have implications for counseling and understanding the psychosocial effects of ADSD.
Analyses of Buckling and Stable Tearing in Thin-Sheet Materials
NASA Technical Reports Server (NTRS)
Seshadri, B. R.; Newman, J. C., Jr.
1998-01-01
This paper was to verify the STAGS (general shell, geometric and material nonlinear) code and the critical crack tip opening angle (CTOA) fracture criterion for predicting stable tearing in cracked panels that fail with severe out of plane buckling. Materials considered ranged from brittle to ductile behavior. Test data used in this study are reported elsewhere. The STAGS code was used to model stable tearing using a critical CTOA value that was determined from a cracked panel that was 'restrained' from buckling. ne analysis methodology was then used to predict the influence of buckling on stable tearing and failure loads. Parameters like crack length to specimen width ratio, crack configuration, thickness, and material tensile properties had a significant influence on the buckling behavior of cracked thin sheet materials. Experimental and predicted results showed a varied buckling response for different crack length to sheet thickness ratios because different buckling modes were activated. Effects of material tensile properties and fracture toughness on buckling response were presented. The STAGS code and the CTOA fracture criterion were able to predict the influence of buckling on stable tearing behavior and failure loads on a variety of materials and crack configurations.
El-Fayoumi, Dina; Youssef, Maha Mohamed; Khafagy, Mohamed Mahmoud; Badr El Dine, Nashwa; Gaber, Wafaa
2018-01-01
To study the corneal changes in rheumatoid arthritis (RA) patients in vivo, using spectral domain anterior segment optical coherence tomography (AS-OCT). A case-control study was done on 43 RA patients and 40 controls. The disease activity score (DAS28-ESR) was calculated and all participants had lower tear meniscus, corneal thickness, and epithelial thickness evaluation using AS-OCT. The lower tear meniscus height (LTMH) and the lower tear meniscus area (LTMA) were significantly lower in the RA patients than in controls (p < 0.001). RA patients also had a significantly thinner central corneal thickness (p = 0.02) and their epithelium was found to be thinner in the superotemporal peripheral sector. The LTMH and LTMA are significantly reduced in RA patients, despite the absence of clinical diagnosis of dry eye. RA patients have thinner corneal thickness and epithelial thickness than controls, which did not correlate with either disease duration or activity.
A two-fluid study of oblique tearing modes in a force-free current sheet
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akçay, Cihan, E-mail: akcay@lanl.gov; Daughton, William; Lukin, Vyacheslav S.
2016-01-15
Kinetic simulations have demonstrated that three-dimensional reconnection in collisionless regimes proceeds through the formation and interaction of magnetic flux ropes, which are generated due to the growth of tearing instabilities at multiple resonance surfaces. Since kinetic simulations are intrinsically expensive, it is desirable to explore the feasibility of reduced two-fluid models to capture this complex evolution, particularly, in the strong guide field regime, where two-fluid models are better justified. With this goal in mind, this paper compares the evolution of the collisionless tearing instability in a force-free current sheet with a two-fluid model and fully kinetic simulations. Our results indicatemore » that the most unstable modes are oblique for guide fields larger than the reconnecting field, in agreement with the kinetic results. The standard two-fluid tearing theory is extended to address the tearing instability at oblique angles. The resulting theory yields a flat oblique spectrum and underestimates the growth of oblique modes in a similar manner to kinetic theory relative to kinetic simulations.« less
The presence and significance of polar meibum and tear lipids.
Pucker, Andrew D; Haworth, Kristina M
2015-01-01
The ocular tear film is a complex structure composed of a number of elements. While all of these components serve valuable functional and structural roles, the external lipid layer has been a focus because it is known to play a critical role in dry eye. Traditionally, meibomian gland phospholipids have been considered to be the vital amphiphilic molecules needed to create an interphase between the outer nonpolar lipid layer and inner aqueous layers, yet recent work has called this theory into question. The purpose of this review is to clarify the current understanding of the origins, identity, and significance of polar tear lipids. Studies indicate that both phospholipids and ω-hydroxy fatty acids likely play a critical role in tear film stability. Studies also indicate that polar lipids likely originate from multiple sources and that they are integrally involved in ocular surface disease. Additional studies are needed to fully understand the origins and significance of polar tear lipids, because to date only correlational evidence has described their hypothesized origins and functions. Copyright © 2015 Elsevier Inc. All rights reserved.
A two-fluid study of oblique tearing modes in a force-free current sheet
Akçay, Cihan; Daughton, William; Lukin, Vyacheslav S.; ...
2016-01-01
Kinetic simulations have demonstrated that three-dimensional reconnection in collisionless regimes proceeds through the formation and interaction of magnetic flux ropes, which are generated due to the growth of tearing instabilities at multiple resonance surfaces. Because kinetic simulations are intrinsically expensive, it is desirable to explore the feasibility of reduced two-fluid models to capture this complex evolution, particularly, in the strong guide field regime, where two-fluid models are better justified. With this goal in mind, this paper compares the evolution of the collisionless tearing instability in a force-free current sheet with a two-fluid model and fully kinetic simulations. Our results indicatemore » that the most unstable modes are oblique for guide fields larger than the reconnecting field, in agreement with the kinetic results. The standard two-fluid tearing theory is extended to address the tearing instability at oblique angles. As a results this theory yields a flat oblique spectrum and underestimates the growth of oblique modes in a similar manner to kinetic theory relative to kinetic simulations.« less
Estimating the Osmolarities of Tears During Evaporation Through the "Eyes" of the Corneal Nerves.
Hirata, Harumitsu; Mizerska, Kamila; Dallacasagrande, Valentina; Rosenblatt, Mark I
2017-01-01
A population of corneal neurons in rats preferentially sense and monitor the hyperosmolar conditions of tears when the tears begin to evaporate during corneal dryness. The present study exploited this ability in an effort to estimate tear osmolarities by comparing the responses to corneal dryness to their responses to hyperosmolar stimuli. Extracellular recordings were performed from single neurons in the trigeminal ganglia innervating the corneas of rats. To determine the extent to which the corneal neurons' responses to drying of the cornea were induced via the activation by hyperosmolar stimuli, we assessed the responses to ocular instillation of 500 and 600 mOsm/L, and a graded series of hyperosmolar stimuli ranging from 350 to 1000 mOsm/L. The magnitudes of the responses to drying of the cornea were matched almost exactly to those induced by the ocular instillation of the 600 mOsm/L stimuli but not the 500 mOsm/L solutions. The response magnitudes to a graded series of hyperosmolar solutions were nearly linear from the 350 to the 600 mOsm/L stimuli, but reached a plateau or declined slightly thereafter. Our results demonstrate that the tear osmolarity in rats could reach 600 to 1000 mOsm/L during ocular dryness. Furthermore, a spontaneous eye blink could be generated at a tear osmolarity of approximately 400 mOsm/L if the blink is solely determined by hyperosmolar tears, but ocular surface cooling also can become a major factor if hyperosmolar tears occurring during ocular dryness lower the threshold of activation of the neurons.
Detection of partial-thickness tears in ligaments and tendons by Stokes-polarimetry imaging
NASA Astrophysics Data System (ADS)
Kim, Jihoon; John, Raheel; Walsh, Joseph T.
2008-02-01
A Stokes polarimetry imaging (SPI) system utilizes an algorithm developed to construct degree of polarization (DoP) image maps from linearly polarized light illumination. Partial-thickness tears of turkey tendons were imaged by the SPI system in order to examine the feasibility of the system to detect partial-thickness rotator cuff tear or general tendon pathology. The rotating incident polarization angle (IPA) for the linearly polarized light provides a way to analyze different tissue types which may be sensitive to IPA variations. Degree of linear polarization (DoLP) images revealed collagen fiber structure, related to partial-thickness tears, better than standard intensity images. DoLP images also revealed structural changes in tears that are related to the tendon load. DoLP images with red-wavelength-filtered incident light may show tears and related organization of collagen fiber structure at a greater depth from the tendon surface. Degree of circular polarization (DoCP) images exhibited well the horizontal fiber orientation that is not parallel to the vertically aligned collagen fibers of the tendon. The SPI system's DOLP images reveal alterations in tendons and ligaments, which have a tissue matrix consisting largely of collagen, better than intensity images. All polarized images showed modulated intensity as the IPA was varied. The optimal detection of the partial-thickness tendon tears at a certain IPA was observed. The SPI system with varying IPA and spectral information can improve the detection of partial-thickness rotator cuff tears by higher visibility of fiber orientations and thereby improve diagnosis and treatment of tendon related injuries.
Mucin deficiency causes functional and structural changes of the ocular surface.
Floyd, Anne M; Zhou, Xu; Evans, Christopher; Rompala, Olivia J; Zhu, Lingxiang; Wang, Mingwu; Chen, Yin
2012-01-01
MUC5AC is the most abundant gel-forming mucin in the ocular system. However, the specific function is unknown. In the present study, a Muc5ac knockout (KO) mouse model was subject to various physiological measurements as compared to its wide-type (WT) control. Interestingly, when KO mice were compared to WT mice, the mean tear break up time (TBUT) values were significantly lower and corneal fluorescein staining scores were significantly higher. But the tear volume was not changed. Despite the lack of Muc5ac expression in the conjunctiva of KO mice, Muc5b expression was significantly increased in these mice. Corneal opacification, varying in location and severity, was found in a few KO mice but not in WT mice. The present results suggest a significant difference in the quality, but not the quantity, of tear fluid in the KO mice compared to WT mice. Dry eye disease is multifactorial and therefore further evaluation of the varying components of the tear film, lacrimal unit and corneal structure of these KO mice may help elucidate the role of mucins in dry eye disease. Because Muc5ac knockout mice have clinical features of dry eye, this mouse model will be extremely useful for further studies regarding the pathophysiology of the ocular surface in dry eye in humans.
[Transplantation of autologous labial salivary glands for severe dry eye].
Luo, Shun-rong; Zou, Liu-he; Yan, Chao; Pan, Zhi-qiang; Liu, Jing-ming; Chen, Zhi-yuan; Yin, Wei-hong
2013-01-01
Autologous labial salivary gland transplantation has been a promising alternative for the treatment of severe dry eye. In this article, we describe the results of the ocular surface changes after labial salivary gland transplantation and investigate the feasibility of this treatment. The results of this technique in 8 patients (eyes) who suffered from severe dry eye were prospectively analyzed after surgery (follow-up of 6 months). The best-corrected visual acuity, Schirmer I test, degree of discomfort, usage of pharmaceutical tear substitutes, tear interferometry and slit lamp examination were investigated at different time before and after surgery. All grafts remained viable and the survival rate is 100%. All patients showed significant increase in the Schirmer's test and they expressed great improvement in their ocular discomfort. The use of artificial tear substitutes was reduced because of the increased ocular surface lubrication. Although the authors' long-term experience still is limited, we believe that the procedure is a promising alternative approach for severe dry eye.
Aging: A Predisposition to Dry Eyes
Hindman, Holly B.
2014-01-01
Dry eye syndrome is a disease of the ocular surface and tear film that is prevalent in older adults. Even though the degree of visual acuity loss in dry eye patients is commonly mild-to-moderate, in the aging population, this minimal change in visual status can lead to a significant decrease in visual function and quality of life. A healthy ocular surface is maintained by appropriate tear production and tear drainage, and deficiencies in this delicate balance can lead to dryness. In the aging eye, risk factors such as polypharmacy, androgen deficiency, decreased blink rates, and oxidative stress can predispose the patient to developing dry eye that is frequently more severe, has higher economic costs, and leads to worse consequences to the well-being of the patient. Understanding why elderly patients are at higher risk for developing dry eyes can provide insights into the diagnosis and management of the growing number of older adults struggling with dry eye and minimize the burden of disease on our aging population. PMID:25197560
A predictive model for the tokamak density limit
Teng, Q.; Brennan, D. P.; Delgado-Aparicio, L.; ...
2016-07-28
We reproduce the Greenwald density limit, in all tokamak experiments by using a phenomenologically correct model with parameters in the range of experiments. A simple model of equilibrium evolution and local power balance inside the island has been implemented to calculate the radiation-driven thermo-resistive tearing mode growth and explain the density limit. Strong destabilization of the tearing mode due to an imbalance of local Ohmic heating and radiative cooling in the island predicts the density limit within a few percent. Furthermore, we found the density limit and it is a local edge limit and weakly dependent on impurity densities. Ourmore » results are robust to a substantial variation in model parameters within the range of experiments.« less
Williams, David L; Mann, Brenda K
2014-01-01
Keratoconjunctivitis sicca (KCS), or dry eye, is a significant medical problem in both humans and dogs. Treating KCS often requires the daily application of more than one type of eye drop in order to both stimulate tear prodcution and provide a tear supplement to increase hydration and lubrication. A previous study demonstrated the potential for a crosslinked hyaluronic acid-based hydrogel (xCMHA-S) to reduce the clinical signs associated with KCS in dogs while using a reduced dosing regimen of only twice-daily administration. The present study extended those results by comparing the use of the xCMHA-S to a standard HA-containing tear supplement in a masked, randomized clinical study in dogs with a clinical diagnosis of KCS. The xCMHA-S was found to significantly improve ocular surface health (conjunctival hyperaemia, ocular irritation, and ocular discharge) to a greater degree than the alternative tear supplement (P = 0.0003). Further, owners reported the xCMHA-S treatment as being more highly effective than the alternative tear supplement (P = 0.0024). These results further demonstrate the efficacy of the xCMHA-S in reducing the clinical signs associated with KCS, thereby improving patient health and owner happiness.
Allergy and allergic mediators in tears.
Leonardi, Andrea
2013-12-01
The identification of inflammatory mediators in the tear fluid have been extensively used in ocular allergy to find either a 'disease marker', to better understand the immune mechanisms involved in the ocular surface inflammation, or to identify potential targets for therapeutic interventions. While the clinical characteristics allow a relatively convincing diagnosis of ocular allergic diseases, in the initial, non active phases, or in the chronic stages, the diagnosis may not be clear. Although not highly specific, total tear IgE can be measured with local tests by inserting a paper strip in the lower meniscus. The measurement of tear specific inflammatory markers, such as histamine, tryptase, ECP, IL-4, IL-5 and eotaxin, may be useful for the diagnosis or monitoring ocular allergy. New technologies such as multiplex bead assays, membrane-bound antibody array and proteomic techniques can characterize the distribution of a wide range of bioactive trace proteins in tears. Dozens of mediators, cytokines, chemokines, growth factors, angiogenic modulators, enzymes and inhibitors were thus identified in small tear samples using these techniques, providing the possible identification of specific biomarker for either specific disease or disease activity. However, to date, there is no a single specific laboratory test suitable for the diagnosis and monitoring of allergic conjunctivitis. Copyright © 2013 Elsevier Ltd. All rights reserved.
Rebamipide ophthalmic suspension for the treatment of dry eye syndrome: a critical appraisal
Kashima, Tomoyuki; Itakura, Hirotaka; Akiyama, Hideo; Kishi, Shoji
2014-01-01
Rebamipide was initially developed and approved for use in treating gastric ulcers and lesions associated with gastritis. Discovery of its ability to increase gastric mucin led to investigations of its effect on ocular surface mucin and the subsequent development for use in dry eye patients. Investigations have confirmed that rebamipide increases corneal and conjunctival mucin-like substances along with improving corneal and conjunctival injury. Clinically, rebamipide ophthalmic suspensions can effectively treat tear deficiency and mucin-caused corneal epithelial damage, and can restore the microstructure responsible for tear stability. Topical rebamipide has also been shown to be effective in treating other ocular surface disorders such as lagophthalmos, lid wiper epitheliopathy, and persistent corneal erosion. Rebamipide’s ability to modify epithelial cell function, improve tear stability, and suppress inflammation in the absence of any known major side effects suggest that it may be a beneficial first drug of choice for severe dry eye treatment and other ocular surface disorders. This review summarizes the history and development of this innovative dry eye treatment from its initial use as an effective stomach medication to its current use in the treatment of dry eye in Japan. PMID:24940041
Rebamipide ophthalmic suspension for the treatment of dry eye syndrome: a critical appraisal.
Kashima, Tomoyuki; Itakura, Hirotaka; Akiyama, Hideo; Kishi, Shoji
2014-01-01
Rebamipide was initially developed and approved for use in treating gastric ulcers and lesions associated with gastritis. Discovery of its ability to increase gastric mucin led to investigations of its effect on ocular surface mucin and the subsequent development for use in dry eye patients. Investigations have confirmed that rebamipide increases corneal and conjunctival mucin-like substances along with improving corneal and conjunctival injury. Clinically, rebamipide ophthalmic suspensions can effectively treat tear deficiency and mucin-caused corneal epithelial damage, and can restore the microstructure responsible for tear stability. Topical rebamipide has also been shown to be effective in treating other ocular surface disorders such as lagophthalmos, lid wiper epitheliopathy, and persistent corneal erosion. Rebamipide's ability to modify epithelial cell function, improve tear stability, and suppress inflammation in the absence of any known major side effects suggest that it may be a beneficial first drug of choice for severe dry eye treatment and other ocular surface disorders. This review summarizes the history and development of this innovative dry eye treatment from its initial use as an effective stomach medication to its current use in the treatment of dry eye in Japan.
Gause, Samuel; Hsu, Kuan-Hui; Shafor, Chancellor; Dixon, Phillip; Powell, Kristin Conrad; Chauhan, Anuj
2016-07-01
Ophthalmic drug for the anterior chamber diseases are delivered into tears by either eye drops or by extended release devices placed in the eyes. The instilled drug exits the eye through various routes including tear drainage into the nose through the canaliculi and transport across various ocular membranes. Understanding the mechanisms relevant to each route can be useful in predicting the dependency of ocular bioavailability on various formulation parameters, such as drug concentration, salinity, viscosity, etc. Mathematical modeling has been developed for each of the routes and validated by comparison with experiments. The individual models can be combined into a system model to predict the fraction of the instilled drug that reaches the target. This review summarizes the individual models for the transport of drugs across the cornea and conjunctiva and the canaliculi tear drainage. It also summarizes the combined tear dynamics model that can predict the ocular bioavailability of drugs instilled as eye drops. The predictions from the individual models and the combined model are in good agreement with experimental data. Both experiments and models predict that the corneal bioavailability for drugs delivered through eye drops is less than 5% due to the small area of the cornea in comparison to the conjunctiva, and the rapid clearance of the instilled solution by tear drainage. A contact lens is a natural choice for delivering drugs to the cornea due to the placement of the contact in the immediate vicinity of the cornea. The drug released by the contact towards the cornea surface is trapped in the post lens tear film for extended duration of at least 30min allowing transport of a large portion into the cornea. The model predictions backed by in vivo animal and clinical data show that the bioavailability increases to about 50% with contact lenses. This realization has encouraged considerable research towards delivering ocular drugs by contact lenses. Commercial contacts are, however, not ideal for drug delivery due to the short release durations which may necessitate wearing multiple lenses each day, reducing the viability of this approach. Recent research has focused on designing contacts that retain all critical properties while increasing the release durations to a few hours or a few days. Beagle dog studies with contact lenses containing vitamin E nanobarriers to attenuate drug transport have shown promising results. Human studies using contacts for drug delivery have also been conducted for allergy therapy but drug eluting contacts are not available in the market for any therapy. Copyright © 2015 Elsevier B.V. All rights reserved.
Predicting success with silicone-hydrogel contact lenses in new wearers.
Best, Nigel; Drury, Laura; Wolffsohn, James S
2013-10-01
to evaluate changes in tear metrics and ocular signs induced by six months of silicone-hydrogel contact lens wear and the difference in baseline characteristics between those who successfully continued in contact lens wear compared to those that did not. Non-invasive Keratograph, Tearscope and fluorescein tear break-up times (TBUTs), tear meniscus height, bulbar and limbal hyperaemia, lid-parallel conjunctival folds (LIPCOF), phenol red thread, fluorescein and lissamine-green staining, and lid wiper epitheliopathy were measured on 60 new contact lens wearers fitted with monthly silicone-hydrogels (average age 36±14 years, 40 females). Symptoms were evaluated by the Ocular Surface Disease Index (OSDI). After six months full time contact lens wear the above metrics were re-measured on those patients still in contact lens wear (n=33). The initial measurements were also compared between the group still wearing lenses after six months and those who had ceased lens wear (n=27). There were significant changes in tear meniscus height (p=0.031), bulbar hyperaemia (p=0.011), fluorescein TBUT (p=0.027), corneal (p=0.007) and conjunctival (p=0.009) staining, LIPCOF (p=0.011) and lid wiper epitheliopathy (p=0.002) after six months of silicone-hydrogel wear. Successful wearers had a higher non-invasive (17.0±8.2s vs 12.0±5.6s; p=0.001) and fluorescein (10.7±6.4s vs 7.5±4.7s; p=0.001) TBUT than drop-outs, although OSDI (cut-off 4.2) was also a strong predictor of success. Silicone-hydrogel lenses induced significant changes in the tear film and ocular surface as well as lid margin staining. Wettability of the ocular surface is the main factor affecting contact lens drop-out. Copyright © 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Tear osmolarity measurements in dry eye related to primary Sjögren's syndrome.
Utine, Canan Asli; Bıçakçıgil, Müge; Yavuz, Sule; Çiftçi, Ferda
2011-08-01
To evaluate the tear osmolarity in patients with dry eye syndrome related to primary Sjögren's Syndrome (SS). Twenty eyes of 10 patients with dry eye and primary SS (Group 1) and 20 eyes of 20 subjects who do not have dry eye syndrome (Group 2) were included in this cross-sectional study. In all eyes, ophthalmic examination was performed in the same order: International Ocular Surface Disease Index survey, visual acuity assessment, conjunctival hyperemia scoring, tear osmolarity measurement with TearLab(™) Osmolarity System, tear film break-up time assessment, corneal fluorescein staining scoring, ocular surface Lissamine Green staining scoring, anesthetized Schirmer test. Dry eye severity was graded according to Dry Eye Workshop (DEWS) classification system. Four eyes with grade 1, four eyes with grade 2, seven eyes with grade 3, and five eyes with grade 4 dryness, according to DEWS system, were included. The mean tear osmolarity value was 301.9 ± 11.40 mOsm/L (range: 290-328) in Group 1, and 294.85 ± 8.33 mOsm/L (range: 283-311) in Group 2 (p = 0.03). In Group 1, tear osmolarity values were positively correlated with OSDI scores (r(18) = 0.55, r(2) = 0.31, p = 0.01), DEWS classification grades (r(18) = 0.73, r(2) = 0.54, p < 0.01), temporal and total corneal staining scores (r(18) = 0.67, r(2) = 0.44, p < 0.01, and r(18) = 0.51, r(2) = 0.26, p = 0.02, respectively), temporal conjunctival staining scores (r(18) = 58, r(2) = 0.34, p < 0.01); and negatively correlated with anesthetized Schirmer test results (r(18) = -0.62, r(2) = 0.38, p < 0.01) and TFBUT (r(18) = -0.50, r(2) = 0.25, p = 0.02). Tear osmolarity values were found to be greater in patients with dry eye syndrome related to primary SS compared to control subjects, and positively correlated with the severity of dry eye.
Noncontact detection of dry eye using a custom designed infrared thermal image system
NASA Astrophysics Data System (ADS)
Su, Tai Yuan; Hwa, Chen Kerh; Liu, Po Hsuan; Wu, Ming Hong; Chang, David O.; Su, Po Fang; Chang, Shu Wen; Chiang, Huihua Kenny
2011-04-01
Dry eye syndrome is a common irritating eye disease. Current clinical diagnostic methods are invasive and uncomfortable for patients. This study developed a custom designed noncontact infrared (IR) thermal image system to measure the spatial and temporal variation of the ocular surface temperature over a 6-second eye-open period. This research defined two parameters: the temperature difference value and the compactness value to represent the temperature change and the irregularity of the temperature distribution on the tear film. Using these two parameters, this study achieved discrimination results for the dry eye and the normal eye groups; the sensitivity is 0.84, the specificity is 0.83, and the receiver operating characteristic area is 0.87. The results suggest that the custom designed IR thermal image system may be used as an effective tool for noncontact detection of dry eye.
Noncontact detection of dry eye using a custom designed IR thermal image system
NASA Astrophysics Data System (ADS)
Su, Tai Yuan; Chen, Kerh Hwa; Liu, Po Hsuan; Wu, Ming Hong; Chang, David O.; Chiang, Huihua
2011-03-01
Dry eye syndrome is a common irritating eye disease. Current clinical diagnostic methods are invasive and uncomfortable to patients. A custom designed noncontact infrared (IR) thermal image system was developed to measure the spatial and temporal variation of the ocular surface temperature over a 6-second eye-opening period. We defined two parameters: the temperature difference value and the compactness value to represent the degree of the temperature change and irregularity of the temperature distribution on the tear film. By using these two parameters, in this study, a linear discrimination result for the dry eye and the normal eye groups; the sensitivity is 0.9, the specificity is 0.86 and the receiver operating characteristic (ROC) area is 0.91. The result suggests that the custom designed IR thermal image system may be used as an effective tool for noncontact detection of dry eye.
Rolando, Maurizio; Cantera, Emilia; Mencucci, Rita; Rubino, Pierangela; Aragona, Pasquale
2018-04-01
To describe a standard approach to manage tear dysfunction (TD), in order to obtain a clinically favourable outcome. TD is a highly prevalent, yet largely underdiagnosed, condition that affects from 5 to 30% of the population above 50 years old. Left untreated, TD is associated with eye discomfort and ocular surface disease, substantially affecting quality of life. Although the prevalence of this problem is increasing significantly, a standard approach to its prevention and treatment is not available yet. In September 2015, a team of Ocular Surface Italian Experts convened for a roundtable to discuss on the latest knowledge about diagnosis and treatments for TD and the real issues in the management of these patients. The discussion centred on the appropriate definition of TD, proposing a new classification of risk factors and how to identify them, how to make a correct diagnosis choosing the rational therapy (questionnaires, symptoms' time relation, seasonality, low tech diagnostic manoeuvres, specific tests for the detection of tear film disturbances leading to recognition of the level of disease and of the ocular system elements involved), which artificial tear matches the ideal profile for a rational therapy and which questions should be done to the patient. A multi-item flowchart for tear film dysfunction, with point-by-point explanatory guide, to better identify and manage the patient with this disorder is provided. The growing prevalence of TD demands increased attention. An appropriate prevention and a treatment pattern for the patient, combined with greater patient-practitioner interaction, and patient education is offered.
Tear oxygen under hydrogel and silicone hydrogel contact lenses in humans.
Bonanno, Joseph A; Clark, Christopher; Pruitt, John; Alvord, Larry
2009-08-01
To determine the tear oxygen tension under a variety of conventional and silicone hydrogel contact lenses in human subjects. Three hydrogel and five silicone hydrogel lenses (Dk/t = 17 to 329) were coated on the back surface with an oxygen sensitive, bovine serum albumin-Pd meso-tetra (4-carboxyphenyl) porphine complex (BSA-porphine). Each lens type was placed on the right eye of 15 non-contact lens wearers to obtain a steady-state open eye tear oxygen tension using oxygen sensitive phosphorescence decay of BSA-porphine. A closed-eye oxygen tension estimate was obtained by measuring the change in tear oxygen tension after 5 min of eye closure. In separate experiments, a goggle was placed over the lens wearing eye and a gas mixture (PO2 = 51 torr) flowed over the lens to simulate anterior lens oxygen tension during eye closure. Mean open eye oxygen tension ranged from 58 to 133 torr. Closed eye estimates ranged from 11 to 42 torr. Oxygen tension under the goggle ranged from 8 to 48 torr and was higher than the closed eye estimate for six out of the eight lenses, suggesting that the average closed eye anterior lens surface oxygen tension is <51 torr. For Dk/t >30, the measured tear oxygen tension is significantly lower than that predicted from previous studies. The phosphorescence decay methodology is capable of directly measuring the in vivo post lens PO2 of high Dk/t lenses without disturbing the contact lens or cornea. Our data indicate that increasing Dk/t up to and beyond 140 continues to yield increased flux into the central cornea.
Do Unilateral Herpetic Stromal Keratitis and Neurotrophic Ulcers Cause Bilateral Dry Eye?
Jabbarvand, Mahmoud; Hashemian, Hesam; Khodaparast, Mehdi; Rafatnejad, Amin; Beheshtnejad, Amirhooshang; Salami, Amir
2015-07-01
To evaluate and compare the ocular surface condition in herpetic interstitial stromal keratitis and neurotrophic ulcer groups and their normal fellow eyes. In this observational, cross-sectional case-control study, 85 consecutive patients were included, including 56 cases of treated herpetic interstitial keratitis and 29 patients with neurotrophic ulcers. Fifty-six age- and sex-matched participants were also recruited from a normal population as the control group. We evaluated and scored the subjective and objective measures of dry eye for both eyes of all patients. Then, we compared the score of the groups with one another and also with the control group. The main outcome measures were the discomfort level, visual symptoms of dry eye, conjunctival injection, conjunctival staining, corneal staining, corneal tear signs of dry eye, meibomian gland dysfunction, tear break-up time, Schirmer test score with anesthesia, and tear osmolarity. The normal fellow eye of the herpetic keratitis group had significantly higher discomfort levels (1.4 ± 0.9 vs. 1.3 ± 0.5, P = 0.003), visual symptoms (1.7 ± 0.8 vs. 1.3 ± 0.7, P = 0.002), tear break-up time (8.3 ± 3.2 vs. 12.1 ± 3.3 seconds, P = 0.003), Schirmer test scores (9.2 ± 3.9 vs. 12.9 ± 3 mm, P = 0.04), and tear osmolarity (9.2 ± 3.9 vs. 12.9 ± 3 mm, P = 0.003) in comparison with normal controls. The normal fellow eyes of the neurotrophic ulcer group had significantly worse values for discomfort level (1.9 ± 0.9 vs. 1.3 ± 0.5, P < 0.001), tear break-up time (7.9 ± 4 vs. 12.1 ± 3.3, P = 0.004), Schirmer test score (8.1 ± 3.9 vs. 12.9 ± 3, P = 0.005), and tear osmolarity (295 ± 9.2 vs. 292.7 ± 5.9, P = 0.02) compared with normal controls. Both eyes of patients with neurotrophic ulcer and interstitial herpetic keratitis have a significantly poorer ocular surface condition compared with that of normal controls.
Diet, nutraceuticals and the tear film.
Jalbert, Isabelle
2013-12-01
Nutrition disorders and their correlates such as obesity are increasingly prevalent worldwide. A number of studies to date have suggested numerous potential associations between diet and tear film health; this paper will provide a summary of the available literature. The tear film is characterized through its protein and lipid content and through clinical measurements of characteristics such as osmolarity, volume and stability. Malnutrition, protein and vitamin-A deficiencies are extremely deleterious to tear film health and supplementation with oral vitamin A in this setting is of clear benefit. The relative impact of diet on tear film within what would be considered normal ranges of consumption is less clear. A number of population studies have suggested that hyperlipidemia and a diet low in omega-3 fatty acids are risks factor for dry eye disease. Numerous studies have investigated the effectiveness of oral supplementation with antioxidants, omega-3 (e.g. fish oil and linseed oil) and omega-6 (e.g. evening primrose oil) fatty acids in the last 10 years. Taken together, these suggest a small benefit of oral supplementation on tear film volume, stability and decreased ocular symptoms in patients previously diagnosed with diseases involving the ocular surface (e.g. Sjögren's syndrome, meibomian gland dysfunction, dry eye disease) and contact lens wearers suffering from dry eye. More research is required to determine the exact composition, dosage and indications for their use and to fully characterize how these nutraceuticals modulate the tear film. Copyright © 2013 Elsevier Ltd. All rights reserved.
Glycomic characterization of basal tears and changes with diabetes and diabetic retinopathy.
Nguyen-Khuong, Terry; Everest-Dass, Arun V; Kautto, Liisa; Zhao, Zhenjun; Willcox, Mark D P; Packer, Nicolle H
2015-03-01
As a secreted fluid, the state of tear glycosylation is particularly important in the role of immunity of the ocular surface. Tears are a valuable source of non-invasive biomarkers for disease and there are continued efforts to characterize their components thoroughly. In this study, a small volume of basal tears (5 μL) was collected from healthy controls, patients with diabetes without retinopathy and patients with diabetes and retinopathy. The detailed N- and O-linked tear protein glycome was characterized and the relative abundance of each structure determined. Of the 50 N-linked glycans found, 89% were complex with 50% containing a bisecting N-acetylglucosamine, 65% containing a core fucose whilst 33% were sialylated. Of the 8 O-linked glycans detected, 3 were of cores 1 and 5 of core 2 type, with a majority of them being sialylated (90%). Additionally, these glycan structures were profiled across the three diabetic disease groups. Whilst the higher abundant structures did not alter across the three groups, only five low abundance N-linked glycans and 1 O-linked glycan did alter with the onset of diabetes mellitus and diabetic retinopathy (DR). These results suggest the conservation of glycan types on basal tear proteins between individuals and point to only small changes in glycan expression on the proteins in tears with the development of diabetes and DR. © The Author 2014. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Möbius, R; Schleifenbaum, S; Grunert, R; Löffler, S; Werner, M; Prietzel, T; Hammer, N
2016-10-01
The removal of well-fixed acetabular components following THA (total hip arthroplasty) is a difficult operation and could be accompanied by the loss of acetabular bone stock. The optimal method for fixation is still under debate. The aim of this pilot study was to compare the tear-out resistance and failure behavior between osseo-integrated and non-integrated screw cups. Furthermore, we examined whether there are differences in the properties mentioned between screw sockets and cemented polyethylene cups. Tear-out resistance and related mechanical work required for the tear-out of osseo-integrated screw sockets are higher than in non-integrated screw sockets. Ten human coxal bones from six cadavers with osseo-integrated screw sockets (n=4), non-integrated (implanted post-mortem, n=3) screw sockets and cemented polyethylene cups (n=3) were used for tear-out testing. The parameters axial failure load and mechanical work for tear-out were introduced as measures for determining the stability of acetabular components following THA. The osseo-integrated screw sockets yielded slightly higher tear-out resistance (1.61±0.26kN) and related mechanical work compared to the non-integrated screw sockets (1.23±0.39kN, P=0.4). The cemented polyethylene cups yielded the lowest tear-out resistance with a failure load of 1.18±0.24kN. Compared to the screw cups implanted while alive, they also differ on a non-significant level (P=0.1). Osseous failure patterns differed especially for the screw sockets compared to the cemented polyethylene cups. Osseo-integration did not greatly influence the tear-out stability in cementless screw sockets following axial loading. Furthermore, the strength of the bone-implant-interface of cementless screw sockets appears to be similar to cemented polyethylene cups. However, given the high failure load, high mechanical load and because of the related bone failure patterns, removal should not be performed by means of tear-out but rather by osteotomes or other curved cutting devices to preserve the acetabular bone stock. Level III, case-control-study. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
The biodurability of covering materials for metallic stents in a bile flow phantom.
Bang, Byoung Wook; Jeong, Seok; Lee, Don Haeng; Lee, Jung Il; Lee, Se Chul; Kang, Sung-Gwon
2012-04-01
Covered biliary metal stents have been introduced for the purpose of overcoming tumor ingrowth and treatment of benign biliary stricture. The aim of this study was to evaluate the biodurability of three commercially available biliary metal stent covering materials [e-PTFE (expanded polytetrafluoroethylene), silicone, and polyurethane] in a bile flow phantom. By operation of a peristaltic pump, human bile was circulated continuously in an experimental perfusion system containing covered metal stents. Each stent was removed, respectively, 1, 2, 4, and 6 months after bile exposure. We performed a gross inspection of the covered stents. The covering membrane was detached from the stent and observed by scanning electron microscopy (SEM). Finally, we measured tensile and tear strength of the membranes. Bile-staining of the membrane showed gradual progression after bile exposure; however, progress was the fastest in e-PTFE. SEM examination showed that the polyurethane surface was smooth, and the silicone surface was relatively smooth. However, e-PTFE had a rough and uneven surface. After bile exposure, there were no significant changes in polyurethane and silicone; however, biofilms and microcracks were observed in e-PTFE. In contrast to a gradual decrease of tensile/tear strength of polyurethane and silicone, those of e-PTFE showed a rapid reduction despite of the strongest baseline tensile and tear strength. e-PTFE tended to form biofilms more frequently than polyurethane and silicone during bile exposure. e-PTFE seemed to be less durable than silicone and polyurethane, however, as clinically applicable material because of strong absolute tensile/tear strengths.
Are the fluctuations in dynamic anterior surface aberrations of the human eye chaotic?
Jayakumar, Varadharajan; Thapa, Damber; Hutchings, Natalie; Lakshminarayanan, Vasudevan
2013-12-15
The purpose of the study is to measure chaos in dynamic anterior surface aberrations and examine how it varies between the eyes of an individual. Noninvasive tear breakup time and dynamic corneal surface aberrations were measured for two open-eye intervals of 15 s. The maximal Lyapunov exponent (MLE) was calculated to test the nature of the fluctuations of the dynamic anterior surface aberrations. The average MLE for total higher-order aberration (HOA) was found to be small (+0.0102±0.0072) μm/s. No significant difference in MLE was found between the eyes for HOA (t-test; p=0.131). Data analysis was carried out for individual Zernike coefficients, including vertical prism as it gives a direct measure of the thickness of the tear film over time. The results show that the amount of chaos was small for each Zernike coefficient and not significantly correlated between the eyes.
Marsovszky, László; Resch, Miklós D; Visontai, Zsuzsanna; Németh, János
2014-07-01
The recently developed confocal cornea microscopy offers the opportunity to examine pathologies of the cornea and to gain insight into the activity of innate immunity. We aimed to investigate the corneal epithelial and Langerhans cell (LC) densities along with dry eye parameters in primary open-angle glaucoma (POAG) subjects, treated with either of two commercially available travoprost 0.004 % topical medications containing different preservatives. (1: benzalkonium chloride 0.015 % (TravBAK) and 2: polyquaternium-1 (PQ) 0.001 % (TravPQ). Consecutive case series of nineteen POAG patients on TravBAK (mean age: 64.8 ± 13.6 years), nineteen POAG patients on TravPQ (mean age: 66.8 ± 11.3 years) and nineteen age-matched healthy control subjects (63.8 ± 8.2 years). Ocular surface disease index (OSDI), lid parallel conjunctival folds (LIPCOF), Schirmer test (ST) and tear break up time (TBUT) were assessed, and then corneal epithelial and LC densities were investigated with confocal microscopy. Tear production was significantly reduced in both glaucoma patient groups compared to healthy individuals (p < 0.05). TBUT was significantly reduced and epithelial cell densities were significantly greater in patients treated with TravBAK compared to healthy individuals (p < 0.05 for all). LC densities were greater in both glaucoma groups compared to control subjects (p < 0.05 for all). Travoprost therapy may compromise ocular surface. The limited alertness of the corneal immune system found in patients with TravPQ can be considered as indicators of a less disturbed ocular surface and better controlled corneal homeostasis.
Albertsmeyer, Ann-Christin; Kakkassery, Vinodh; Spurr-Michaud, Sandra; Beeks, Olivia; Gipson, Ilene K
2010-03-01
Membrane-associated mucins are altered on the ocular surface in non-Sjögren's dry eye. This study sought to determine if inflammatory mediators, present in tears of dry eye patients, regulate membrane-associated mucins MUC1 and -16 at the level of gene expression, protein biosynthesis and/or ectodomain release. A human corneal limbal epithelial cell line (HCLE), which produces membrane-associated mucins, was used. Cells were treated with interleukin (IL)-6, -8, or -17, tumor necrosis factor-alpha (TNF-alpha), and Interferon-gamma (IFN-gamma), or a combination of TNF-alpha and IFN-gamma, or IFN-gamma and IL-17, for 1, 6, 24, or 48 h. Presence of receptors for these mediators was verified by RT-PCR. Effects of the cytokines on expression levels of MUC1 and -16 were determined by real-time PCR, and on mucin protein biosynthesis and ectodomain release in cell lysates and culture media, respectively, by immunoblot analysis. TNF-alpha and IFN-gamma each significantly induced MUC1 expression, cellular protein content and ectodomain release over time. Combined treatment with the two cytokines was not additive. By comparison, one of the inflammatory mediators, IFN-gamma, affected all three parameters-gene expression, cellular protein, and ectodomain release-for MUC16. Combined treatment with TNF-alpha and IFN-gamma showed effects similar to IFN-gamma alone, except that ectodomain release followed that of TNF-alpha, which induced MUC16 ectodomain release. In conclusion, inflammatory mediators present in tears of dry eye patients can affect MUC1 and -16 on corneal epithelial cells and may be responsible for alterations of surface mucins in dry eye.
Foldvari, Marianna
2014-01-01
Drug delivery to the eye is made difficult by multiple barriers (such as the tear film, cornea, and vitreous) between the surface of the eye and the treatment site. These barriers are difficult to surmount for the purposes of drug delivery without causing toxicity. Using nanotechnology tools to control, manipulate, and study delivery systems, new approaches to delivering drugs, genes, and antigens that are effective and safe can be developed. Topical administration to the ocular surface would be the safest method for delivery, as it is noninvasive and painless compared with other delivery methods. However, there is only limited success using topical delivery methods, especially for gene therapy. Current thinking on treatments of the future enabled by nanodelivery systems and the identification of target specificity parameters that require deeper understanding to develop successful topical delivery systems for glaucoma is highlighted.
Wu, Yvonne T.; Tam, Connie; Zhu, Lucia S.; Evans, David J.; Fleiszig, Suzanne M. J.
2017-01-01
Purpose The type III secretion system (T3SS) is a significant virulence determinant for Pseudomonas aeruginosa. Using a rodent model, we found that contact lens (CL)-related corneal infections were associated with lens surface biofilms. Here, we studied the impact of human tear fluid on CL-associated biofilm growth and T3SS expression. Methods P. aeruginosa biofilms were formed on contact lenses for up to 7 days with or without human tear fluid, then exposed to tear fluid for 5 or 24 h. Biofilms were imaged using confocal microscopy. Bacterial culturability was quantified by viable counts, and T3SS gene expression measured by RT-qPCR. Controls included trypticase soy broth, PBS and planktonic bacteria. Results With or without tear fluid, biofilms grew to ~108 cfu viable bacteria by 24 h. Exposing biofilms to tear fluid after they had formed without it on lenses reduced bacterial culturability ~180-fold (p<.001). CL growth increased T3SS gene expression versus planktonic bacteria [5.46 ± 0.24-fold for T3SS transcriptional activitor exsA (p=.02), and 3.76 ± 0.36-fold for T3SS effector toxin exoS (p=.01)]. Tear fluid further enhanced exsA and exoS expression in CL-grown biofilms, but not planktonic bacteria, by 2.09 ± 0.38-fold (p = 0.04) and 1.89 ± 0.26-fold (p<.001), respectively. Conclusions Considering the pivitol role of the T3SS in P. aeruginosa infections, its induction in CL-grown P. aeruginosa biofilms by tear fluid might contribute to the pathogenesis of CL-related P. aeruginosa keratitis. PMID:27670247
Tear clearance and ocular symptoms in patients treated with preservative-free prostaglandins.
Giménez-Gómez, R; García-Catalán, M R; Gallardo-Galera, J M
2013-03-01
To assess the effects on dry eye symptoms and tear dynamics of switching from a prostaglandin with a preservative to a preservative-free prostaglandin. Fourteen patients (N=28 eyes) with open-angle glaucoma and dry eye symptons, treated with preserved latanoprost, travoprost or bimatoprost were included in this uncontrolled prospective study. Ocular symptoms were analysed using a validated ocular surface disease questionnaire and ocular signs were assessed with tear clearance, Schirmer and tear function index test (TFI=Schirmer/clearance). Patients were assigned to preservative-free tafluprost treatment, and measurements were repeated 4 weeks after change of medication. Wilcoxon test and Spearman correlation coefficient were used in the statistical analysis. No statistically significant difference in intraocular pressure (IOP) was observed after switching to tafluprost. Mean IOP at baseline was 20.4 mmHg (SD2.2) and after 4 weeks 19.9 mmHg (SD2.6), (P>.05). The mean questionnaire score significantly decreased from 9.7 (SD3.7) at baseline to 5.4 (SD2.7) after one month (P<.001). No significant differences in tear clearance, Schirmer or TFI were found (P>.05). At baseline, tear clearance=0.13 (SD0.07), Schirmer=10.7 mm (SD6) and TFI=80 (48-156). After 4 weeks, tear clearance=0.1(SD0.07), Schirmer=9.5 mm (3.9) and TFI=104 (48-216). A significant association between questionnaire score and tear clearance after 4 weeks was observed (Spearman coefficient=0.62; P=.014). Switching from preservative prostaglandin with a preservative to preservative-free tafluprost treatment improves dry eye symptoms and suggests an improvement in TFI. Copyright © 2012 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.
Effects of punctal occlusion on global tear proteins in patients with dry eye.
Tong, Louis; Zhou, Lei; Beuerman, Roger; Simonyi, Susan; Hollander, David A; Stern, Michael E
2017-10-01
To investigate effects of punctal occlusion on global tear protein levels in patients with dry eye. In this prospective, longitudinal, single-center study, nonabsorbable punctal plugs were inserted bilaterally into the lower punctum of 30 patients with moderate dry eye. Dry eye symptoms, fluorescein corneal staining, Schirmer I test, tear film break-up time, and safety were assessed in the more severely affected eye. Tear proteins at weeks 1 and 3 were quantified by iTRAQ relative to baseline preocclusion levels. Of 29 patients who completed the study, 23 (mean age 49.8 years) had sufficient tear samples for analysis. After 3 weeks, punctal occlusion significantly upregulated tear proteins, including glutathione synthase (mean of 1.6-fold, P = 0.01) and interleukin-1 receptor antagonist (1.7-fold, P = 0.032) and downregulated cholinergic receptor (neuronal) alpha-7 (0.79-fold, P = 0.039) and lymphocyte cytosolic protein-1 (0.66-fold, P = 0.012). Clustering analysis of global tear proteins revealed two clear profile changes; the first group of patients (cluster 1, n = 10) had a reduction in the inflammatory proteins (e.g., S100A8) and rise in lacrimal proteins supporting the ocular surface (e.g., lysozyme), whereas the second group (cluster 2, n = 13) had an increase in inflammatory proteins and a decrease in lacrimal proteins. Logistic regression analysis revealed that cluster 1 patients had significantly (P = 0.006) lower Schirmer scores at baseline (mean [standard deviation]: 4.3 [4.3] mm) than cluster 2 (6.8 [2.6] mm). Punctal plugs produced a beneficial pattern of tear protein change in patients with relatively low Schirmer scores within 3 weeks of punctal occlusion. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Terabayashi, Nobuo; Watanabe, Tsuneo; Matsumoto, Kazu; Takigami, Iori; Ito, Yoshiki; Fukuta, Masashi; Akiyama, Haruhiko; Shimizu, Katsuji
2014-09-01
Night pain is a particularly vexing symptom in patients with rotator cuff tear. It disturbs sleep and decreases quality of life, and there is no consensus regarding its etiology. Based on arthroscopic surgical observations of synovitis around the rotator interval or capsule surface in rotator cuff tear, we hypothesized that blood flow from the artery feeding the capsule increases blood supply to the synovium. This study aimed to investigate the relationship between blood flow and night pain using pulse Doppler ultrasonography. A series of 47 consecutive patients with rotator cuff tear was evaluated. The peak systolic velocity and resistance index of blood flow in the ascending branch of the anterior humeral circumflex artery were evaluated using pulse Doppler ultrasonography. We also investigated 20 normal shoulders in healthy volunteers. The peak systolic velocity and resistance index were compared between affected and unaffected sides in patients and between dominant and nondominant sides in controls. Anterior humeral circumflex artery peak systolic velocity and resistance index did not differ between sides in control subjects or in patients with rotator cuff tear without night pain. However, anterior humeral circumflex artery peak systolic velocity and resistance index did differ significantly between sides in patients with rotator cuff tear with night pain. This study revealed anterior humeral circumflex artery hemodynamics in patients with rotator cuff tear and normal subjects using Doppler ultrasonography. Night pain, particularly involving aching, appears to be related to the hemodynamics. These findings suggest that investigating the hemodynamics of patients with rotator cuff tear with night pain may lead to greater understanding of the etiology of this symptom.
Miñones Conde, M; Conde, O; Trillo, J M; Miñones, J
2011-04-05
Mixed monolayers of poly(methyl methacrylate) (PMMA), the main component of hard contact lenses, and dipalmitoyl phosphatidyl choline (DPPC), a characteristic phospholipidic constituent of ocular tear films, were selected as an in vitro model in order to observe the behavior of contact lenses on the eye. Using Langmuir monolayer and Brewster angle microscopy (BAM) techniques, the interaction between both components was analyzed from the data of surface pressure-area isotherms, compressional modulus-surface pressure, and relative film thickness versus time elapsed from the beginning of compression, together with BAM images. Regardless of the surface pressure at which the molecular/monomer areas (A(m)) were recorded, the A(m) mole fractions of PMMA (X(PMMA)) plots show that the experimental results match the theoretical values calculated from additivity rule A(m) = X(PMMA)A(PMMA) + X(DPPC)A(DPPC). The application of the Crisp phase rule to the phase diagram of the PMMA-DPPC system can explain the existence of a mixed monolayer made up of miscible components with ideal behavior at surface pressures below 25 mN/m. However, at very high surface pressures, when collapse is reached (at 60 mN/m), the single collapsed components are segregated into two independent phases. These results allows us to argue that PMMA hard contact lenses in the eye do not alter the structural characteristics of the phospholipid (DPPC) in tears.
Sebum/Meibum Surface Film Interactions and Phase Transitional Differences.
Mudgil, Poonam; Borchman, Douglas; Gerlach, Dylan; Yappert, Marta C
2016-05-01
Sebum may contribute to the composition of the tear film lipid layer naturally or as a contaminant artifact from collection. The aims of this study were to determine: if sebum changes the rheology of meibum surface films; if the resonance near 5.2 ppm in the 1H-NMR spectra of sebum is due to squalene (SQ); and if sebum or SQ, a major component of sebum, interacts with human meibum. Human meibum was collected from the lid margin with a platinum spatula. Human sebum was collected using lipid absorbent tape. Langmuir trough technology was used to measure the rheology of surface films. Infrared spectroscopy was used to measure lipid conformation and phase transitions. We used 1H-NMR to measure composition and confirm the primary structure of SQ. The NMR resonance near 5.2 ppm in the spectra of human sebum was from SQ which composed 28 mole percent of sebum. Both sebum and SQ lowered the lipid order of meibum. Sebum expanded meibum films at lower concentrations and condensed meibum films at higher concentrations. Sebum caused meibum to be more stable at higher pressures (greater maximum surface pressure). Physiological levels of sebum would be expected to expand or fluidize meibum making it spread better and be more surface active (qualities beneficial for tear film stability). Sebum would also be expected to stabilize the tear film lipid layer, which may allow it to withstand the high shear pressure of a blink.
Sebum/Meibum Surface Film Interactions and Phase Transitional Differences
Mudgil, Poonam; Borchman, Douglas; Gerlach, Dylan; Yappert, Marta C.
2016-01-01
Purpose Sebum may contribute to the composition of the tear film lipid layer naturally or as a contaminant artifact from collection. The aims of this study were to determine: if sebum changes the rheology of meibum surface films; if the resonance near 5.2 ppm in the 1H-NMR spectra of sebum is due to squalene (SQ); and if sebum or SQ, a major component of sebum, interacts with human meibum. Methods Human meibum was collected from the lid margin with a platinum spatula. Human sebum was collected using lipid absorbent tape. Langmuir trough technology was used to measure the rheology of surface films. Infrared spectroscopy was used to measure lipid conformation and phase transitions. We used 1H-NMR to measure composition and confirm the primary structure of SQ. Results The NMR resonance near 5.2 ppm in the spectra of human sebum was from SQ which composed 28 mole percent of sebum. Both sebum and SQ lowered the lipid order of meibum. Sebum expanded meibum films at lower concentrations and condensed meibum films at higher concentrations. Sebum caused meibum to be more stable at higher pressures (greater maximum surface pressure). Conclusions Physiological levels of sebum would be expected to expand or fluidize meibum making it spread better and be more surface active (qualities beneficial for tear film stability). Sebum would also be expected to stabilize the tear film lipid layer, which may allow it to withstand the high shear pressure of a blink. PMID:27145473
Ikeda, Keisuke; Simsek, Cem; Kojima, Takashi; Higa, Kazunari; Kawashima, Motoko; Dogru, Murat; Shimizu, Takahiko; Tsubota, Kazuo; Shimazaki, Jun
2018-04-01
The purpose of the study is to investigate the effect of 3% diquafosol sodium eye drops on meibomian gland and ocular surface alterations in the superoxide dismutase-1 (Sod1 -/- ) mice in comparison to the wild-type mouse. Three percent diquafosol sodium eye drop was instilled to 20 eyes of 10 50-week-old male Sod1 -/- mice and 22 eyes of 11 C57BL/6 strain 50-week-old wild-type (WT) male mice six times a day for 2 weeks. Aqueous tear secretion quantity was measured with phenol red-impregnated cotton threads without anesthesia. Tear film stability and corneal epithelial damage were assessed by fluorescein and lissamine green staining. We also performed oil red O (ORO) lipid staining to evaluate the lipid changes in the meibomian glands. Meibomian gland specimens underwent hematoxylin and eosin staining to examine histopathological changes and meibomian gland acinar unit density after sacrifice. Immunohistochemistry staining was performed using cytokeratin 4, cytokeratin 13, and transglutaminase-1 antibodies. Quantitative real-time polymerase chain reaction for cytokeratin 4, cytokeratin 13, and transglutaminase-1 mRNA expression was also performed. The aqueous tear quantity, the mean tear film breakup time, and the number of lipid droplets significantly improved in the Sod1 -/- mice with treatment. The mean meibomian acinar unit density did not change in the Sod1 -/- mice and WT mice after treatment. Application of 3% diquafosol sodium eye drop significantly decreased the corneal fluorescein and lissamine green staining scores in the Sod1 -/- mice after 2 weeks. We showed a notable increase in cytokeratin 4, cytokeratin 13 immunohistochemistry staining, and cytokeratin 4, cytokeratin 13 mRNA expressions with a marked decrease in immunohistochemistry staining and significant decline in mRNA expression of transglutaminase-1 after 3% diquafosol sodium treatment. Topical application of 3% diquafosol sodium eye drop improved the number of lipid droplets, tear stability, and tear production which in turn appeared to have a favorable effect on the ocular surface epithelium. Three percent diquafosol sodium eye drop may be a potential treatment for age-related meibomian gland and dry eye disease based on the observations of the current study.
NASA Astrophysics Data System (ADS)
Portner, D. E.; Kiraly, A.; Makushkina, A.; Parks, B. H.; Ghosh, T.; Haynie, K. L.; Metcalf, K.; Manga, M.; O'Farrell, K. A.; Moresi, L. N.; Jadamec, M. A.; Stern, R. J.
2017-12-01
Large-scale detachment of subducting slabs can have a significant geologic footprint by altering the slab-driven mantle flow field as hot subslab mantle can flow upward through the newly developed opening in the slab. The resulting increase in heat and vertical motion in the mantle wedge may contribute to volcanism and broad surface uplift. Recent geodynamic modeling results show that smaller tears and holes are similarly likely to form in many settings, such as where oceanic ridges or continental fragments subduct. High-resolution seismic tomography models are imaging an increasing number of these gaps and tears ranging in size from tens to hundreds of km in size, many of which occur proximal to alkali volcanism. Here we investigate the role of such gaps on the subduction-induced mantle flow field and related surface response. In particular, we address the relationships between slab hole size, depth, and distance from the slab edge and the magnitude of dynamic response of the mantle using analog experiments and numerical simulations. In the laboratory models, the subduction system is simplified to a two-layered Newtonian viscous sheet model. Our setup consists of a tank filled with glucose syrup and a plate made from silicon putty to model the upper mantle and subducting lithosphere, respectively. In each experiment, we pre-cut a rectangular hole with variable width into the silicon putty plate. Additionally, we perform a series of complementary numerical models using the Underworld geophysical modeling code to calculate the more detailed instantaneous mantle flow perturbation induced by the slab hole. Together, these results imply a strong effect of hole size on mantle flow. Similarly, the depth of the slab hole influences near-surface flow, with significant surface flow alteration when the hole is near the trench and diminishing surface deformation as the hole is dragged deeper into the mantle. The inferred consequence of the dependence of vertical mantle flux on slab hole position and size is that the induced surface response can vary based on slab hole parameters.
Trace elements and diabetes: Assessment of levels in tears and serum.
Cancarini, A; Fostinelli, J; Napoli, L; Gilberti, M E; Apostoli, P; Semeraro, F
2017-01-01
Tear film is critical for the well-being and homeostasis of the ocular surface. Although the composition of the tear film is well known, the composition of metallic elements have yet to be analysed. Despite trace elements metabolism has been reported to play a role in the pathogenesis of diabetes mellitus, a metabolic disease that affects several aspects of homeostasis, little is known in the literature regarding concentration and possible variation of metallic elements in tear film. We studied the concentrations of several essential and non-essential metallic elements in the tear fluid and serum of patients with type II diabetes mellitus and a group of non-diabetic controls. Serum and tear fluid were collected from 97 patients: 47 type II diabetic patients and 50 non-diabetic controls. Regarding tear film, there were statistically significant differences in Zinc, Chrome, Cobalt, Manganese, Barium, and Lead between groups; the values of all metallic elements were found to be statistically significant higher in patients with mellitus type II diabetes. Regarding serum values there was a statistically significant difference in Chrome, Cobalt, and Selenium values; the concentrations of Chrome and Cobalt were higher in the control group, while Selenium concentration was higher in diabetic patients. In patients with type II diabetes, metal elements with higher concentrations in tears compared to serum were: Lead, Barium, Manganese, Cobalt, and Chrome. In the control group, the metal elements with the highest concentration in tear film compared to serum were Chrome, Manganese, Barium, and Lead. In this study, we attempted to evaluate the possible effect of a disease, such as diabetes, on the metabolism of metallic elements. Although our evidence was very interesting, it is probably limited in its accuracy due to the fact that individuals in the control group harboured ocular pathologies. This work lays the foundation for future studies. Copyright © 2016 Elsevier Ltd. All rights reserved.
Mucin-type O-glycans in Tears of Normal Subjects and Patients with Non-Sjögren’s Dry Eye
Guzman-Aranguez, Ana; Mantelli, Flavio; Argüeso, Pablo
2009-01-01
Purpose O-linked carbohydrates (O-glycans) contribute to the hydrophilic character of mucins in mucosal tissues. This study aimed to identify the repertoire of O-glycans in the tear film, and the glycosyltransferases associated with their biosynthesis, in normal subjects and patients with non-Sjögren’s dry eye. Methods Human tear fluid was collected from the inferior conjunctival fornix. O-glycans were released by hydrazinolysis, labeled with 2-aminobenzamide, and analyzed by fluorometric, high-performance liquid chromatography (HPLC) coupled with exoglycosidase digestions. O-glycan structures identified in tears were related to potential biosynthetic pathways in human conjunctival epithelium using a glycogene microarray database. Lectin-binding analyses were performed using agglutinins from Arachis hypogaea, Maackia amurensis, and Sambucus nigra. Results The O-glycan profile of human tears consisted primarily of core 1 (Galβ1-3GalNAcα1-Ser/Thr)-based structures. Mono-sialyl O-glycans represented approximately 66% of the glycan pool, being α2-6-sialyl core 1 the predominant O-glycan structure in human tears (48%). Four families of glycosyltranferases potentially related to the biosynthesis of these structures were identified in human conjunctiva. These included thirteen polypeptide-GalNAc-transferases (GALNT), the core 1 β-3-galactosyltransferase (T-synthase), three α2-6-sialyltransferases (ST6GalNAc), and two α2-3-sialyltransferases (ST3Gal). No significant differences in total amount of O-glycans were detected between tears of normal subjects and dry eye patients, by HPLC and lectin blot. Likewise, no differences in glycosyltransferase expression were found by glycogene microarray. Conclusions This study identifies the most common mucin-type O-glycans in human tears and their expected biosynthetic pathways in ocular surface epithelia. Patients with non-Sjögren’s dry eye show no alterations in composition and amount of O-glycans in the tear fluid. PMID:19407012
An update on dry eye disease molecular treatment: advances in drug pipelines.
Colligris, Basilio; Crooke, Almudena; Huete-Toral, Fernando; Pintor, Jesus
2014-07-01
Dry eye disease is a common disorder provoking changes in tear film and ocular surface. Untreated dry eye could cause ocular infections, corneal ulcer and blindness. Only a few drugs are authorized so far for the treatment of dry eye disease and the possibilities of evolution in this sector are immense. Consequently, a significant number of new potential solutions are under development or placed in the pharmaceutical pipeline, promising better results and lesser side effects. In this article, the corresponding literature and recent Phase III clinical trial data and the corresponding literature, for dry eye disease treatment are reviewed, revealing the new strategic movements in drug pipelines. From the clinical trial results, the advancement in tear substitutes and secretagogues in addressing specific deficiencies of tear components even though not resolving the underlying conditions of the disease is evident. The vast majority of new compounds under development are anti-inflammatories, steroids, non-steroids and antibiotics; however, there are also some novel lubricating drops and mucin-tear secretagogues. A future aggressive therapy for dry eye, depending on the severity of the symptoms, would include combinations of soft steroids, anti-inflammatories, such as cyclosporine A, with the addition of the new polyvalent mucin and tear secretagogues.
Brooks, Brian P; Thompson, Amy H; Bishop, Rachel J; Clayton, Janine A; Chan, Chi-Chao; Tsilou, Ekaterini T; Zein, Wadih M; Tamura, Deborah; Khan, Sikandar G.; Ueda, Takahiro; Boyle, Jennifer; Oh, Kyu-Seon; Imoto, Kyoko; Inui, Hiroki; Moriwaki, Shin-Ichi; Emmert, Steffen; Iliff, Nicholas T.; Bradford, Porcia; DiGiovanna, John J.; Kraemer, Kenneth H
2013-01-01
Objective Xeroderma pigmentosum (XP) is a rare autosomal recessive disease caused by mutations in DNA repair genes. Clinical manifestations of XP include mild to extreme sensitivity to ultraviolet radiation resulting in inflammation and neoplasia in sun-exposed areas of the skin, mucous membranes, and ocular surfaces. This report describes the ocular manifestations of XP in patients systematically evaluated in the Clinical Center at the National Institutes of Health. Design Retrospective Observational Case Series Participants Eighty-seven participants, aged 1.3 to 63.4 years, referred to the National Eye Institute for examination from 1964 to 2011. Eighty-three had XP, 3 had XP/Cockayne Syndrome complex, and 1 had XP/trichothiodystrophy complex. Methods Complete, age- and developmental stage-appropriate ophthalmic examination. Main Outcome Measures Visual acuity; eyelid, ocular surface and lens pathology; tear film and tear production measures; and cytological analysis of conjunctival surface swabs. Results Of the 87 patients, 91% had at least one ocular abnormality. The most common abnormalities were conjunctivitis (51%), corneal neovascularization (44%), dry eye (38%), corneal scarring (26%), ectropion (25%), blepharitis (23%), conjunctival melanosis (20%), and cataracts (14%). Thirteen percent of patients had some degree of visual axis impingement and 5% had no light perception in one or both eyes. Ocular surface cancer or a history of ocular surface cancer was present in 10% of patients. Patients with an acute sunburning skin phenotype were less likely to develop conjunctival melanosis and ectropion but more likely to develop neoplastic ocular surface lesions than non-burning patients. Some patients also showed signs of limbal stem cell deficiency. Conclusions Our longitudinal study reports the ocular status of the largest group of XP patients systematically examined at one facility over an extended period of time. Structural eyelid abnormalities, neoplasms of the ocular surface and eyelids, tear film and tear production abnormalities, ocular surface disease and inflammation, as well as corneal abnormalities were present in this population. Burning and non-burning XP patients exhibit different rates of important ophthalmologic findings, including neoplasia. Additionally, ophthalmic characteristics can help refine diagnoses in the case of XP complex phenotypes. DNA repair plays major role in protection of the eye from sunlight induced damage. PMID:23601806
Tearing-off method based on single carbon nanocoil for liquid surface tension measurement
NASA Astrophysics Data System (ADS)
Wang, Peng; Pan, Lujun; Deng, Chenghao; Li, Chengwei
2016-11-01
A single carbon nanocoil (CNC) is used as a highly sensitive mechanical sensor to measure the surface tension coefficient of deionized water and alcohol in the tearing-off method. The error can be constrained to within 3.8%. Conversely, the elastic spring constant of a CNC can be accurately measured using a liquid, and the error is constrained to within 3.2%. Compared with traditional methods, the CNC is used as a ring and a sensor at the same time, which may simplify the measurement device and reduce error, also all measurements can be performed under a very low liquid dosage owing to the small size of the CNC.
Wang, Z X; Chen, S L; Wang, Q Q; Liu, B; Zhu, J; Shen, J
2015-06-01
The aim of this study was to evaluate the accuracy of magnetic resonance imaging in the detection of triangular fibrocartilage complex injury through a meta-analysis. A comprehensive literature search was conducted before 1 April 2014. All studies comparing magnetic resonance imaging results with arthroscopy or open surgery findings were reviewed, and 25 studies that satisfied the eligibility criteria were included. Data were pooled to yield pooled sensitivity and specificity, which were respectively 0.83 and 0.82. In detection of central and peripheral tears, magnetic resonance imaging had respectively a pooled sensitivity of 0.90 and 0.88 and a pooled specificity of 0.97 and 0.97. Six high-quality studies using Ringler's recommended magnetic resonance imaging parameters were selected for analysis to determine whether optimal imaging protocols yielded better results. The pooled sensitivity and specificity of these six studies were 0.92 and 0.82, respectively. The overall accuracy of magnetic resonance imaging was acceptable. For peripheral tears, the pooled data showed a relatively high accuracy. Magnetic resonance imaging with appropriate parameters are an ideal method for diagnosing different types of triangular fibrocartilage complex tears. © The Author(s) 2015.
Rebamipide increases the mucin-like glycoprotein production in corneal epithelial cells.
Takeji, Yasuhiro; Urashima, Hiroki; Aoki, Akihiro; Shinohara, Hisashi
2012-06-01
Dry eye is a multifactorial disease of tears and the ocular surface due to tear deficiency or excessive tear evaporation. Tear film instability is due to a disturbance in ocular surface mucin leading to a dysfunction of mucin, resulting in dry eye. In this study, we examined the effect of rebamipide, an anti-ulcer agent, on glycoconjugate production, as an indicator of mucin-like glycoprotein in cultured corneal epithelial cells. Further, we investigated the effect of rebamipide on the gene expression of membrane-associated mucins. Confluent cultured human corneal epithelial cells were incubated with rebamipide for 24 h. The glycoconjugate content in the supernatant and the cell extracts was measured by wheat germ agglutinin-enzyme-linked lectin assay combined gel-filtration method. In the experiment on mucin gene expression, cultured human corneal epithelial cells were collected at 0, 3, 6, and 12 h after administration of rebamipide. Real-time quantitative polymerase chain reaction was used to analyze the quantity of MUC1, MUC 4, and MUC16 gene expression. Rebamipide significantly increased the glycoconjugate contents in the supernatant and cell extract. In the mucin gene expression in the cells, rebamipide increased MUC1 and MUC4 gene expression, but did not increase MUC16 gene expression. Rebamipide promoted glycoconjugate, which has a property as a mucin-like glycoprotein, in human corneal epithelial cells. The increased production was mediated by MUC1 and MUC4 gene expression.
Mucin Deficiency Causes Functional and Structural Changes of the Ocular Surface
Evans, Christopher; Rompala, Olivia J.; Zhu, Lingxiang; Wang, Mingwu; Chen, Yin
2012-01-01
MUC5AC is the most abundant gel-forming mucin in the ocular system. However, the specific function is unknown. In the present study, a Muc5ac knockout (KO) mouse model was subject to various physiological measurements as compared to its wide-type (WT) control. Interestingly, when KO mice were compared to WT mice, the mean tear break up time (TBUT) values were significantly lower and corneal fluorescein staining scores were significantly higher. But the tear volume was not changed. Despite the lack of Muc5ac expression in the conjunctiva of KO mice, Muc5b expression was significantly increased in these mice. Corneal opacification, varying in location and severity, was found in a few KO mice but not in WT mice. The present results suggest a significant difference in the quality, but not the quantity, of tear fluid in the KO mice compared to WT mice. Dry eye disease is multifactorial and therefore further evaluation of the varying components of the tear film, lacrimal unit and corneal structure of these KO mice may help elucidate the role of mucins in dry eye disease. Because Muc5ac knockout mice have clinical features of dry eye, this mouse model will be extremely useful for further studies regarding the pathophysiology of the ocular surface in dry eye in humans. PMID:23272068
Ren Shiyou; Sun, Limang; Chen, Guofei; Jiang, Changqing; Zhang, Xintao; Zhang Wentao
2015-01-01
To investigate the reliability of the "ripple sign" on the upper surface of the medial femoral condyle in the diagnosis of medial longitudinal meniscal tears under arthroscope. Between June 2013 and June 2014, 56 patients with knee injuries were included. There were 35 males and 21 females with an average age of 22.2 years (range, 12-38 years). The causes of injury were sports in 40 cases, falling in 10 cases, and traffic accident in 6 cases. The injury was located at the left knee in 22 cases and at the right knee in 34 cases. The disease duration was 10-40 days (mean, 20.2 days). Of 56 patients, 15 cases had simple medial meniscal injury; 41 cases had combined injuries, including anterior cruciate ligament injury in 38 cases, posterior cruciate ligament injury in 2 cases, and patellar dislocation in 1 case. The "ripple sign" was observed under arthroscope before operation. Repair of medial meniscal injury and reconstruction of cruciate ligament were performed. The positive "ripple sign" was seen under arthroscope in all patients, who were diagnosed to have longitudinal meniscal tears, including 23 cases of mild "ripple sign" , 28 cases of moderate "ripple sign", and 5 cases of severe "ripple sign". The "ripple sign" on the upper surface of the medial femoral condyle is a reliable diagnostic evidence of medial longitudinal meniscal tears.
Postanaesthetic tear production and ocular irritation in cats.
Peche, N; Köstlin, R; Reese, S; Pieper, K
2015-01-01
General anaesthesia significantly reduces tear production and normal values are not immediately re-established on ending anaesthesia. Therefore, adequate protection of the cornea has to be assured during the perianaesthetic period. There are various methods available, including taping of the eyelids and the application of eye ointments, gels and drops. In human medicine studies, different formulations were found to induce signs of ocular irritation. The aim of the present study was to determine tear production in cats after general anaesthesia, and to identify possible causes of irritation. Tear production was determined in 41 cats after general anaesthesia and eyes were examined for signs of irritation. Two different anaesthetic protocols were used. To protect the cornea, an ointment and gel were applied to the right and left eyes, respectively. Postoperatively, tear production was significantly reduced for 6 hours and 18 hours in the right and left eyes, respectively. Two hours after anaesthesia, blepharospasm of the right eye was observed in 92.7% (n = 38) of the cats. In contrast, the left eye was always held open. This study demonstrated that tear production in cats is significantly decreased both during and after anaesthesia. The degree of reduction was independent of the anaesthetic protocol. Both the eye ointment and gel proved effective in protecting the corneal surface. However, eye gel use is recommended because the eye ointment consistently caused an irritation comparable to the foreign-body sensation reported in humans.
Comparative analysis of two femtosecond LASIK platforms using iTRAQ quantitative proteomics.
D'Souza, Sharon; Petznick, Andrea; Tong, Louis; Hall, Reece C; Rosman, Mohamad; Chan, Cordelia; Koh, Siew Kwan; Beuerman, Roger W; Zhou, Lei; Mehta, Jodhbir S
2014-05-06
New femtosecond laser platforms may reduce ocular surface interference and LASIK-associated dry eye. This study investigated tear protein profiles in subjects who underwent LASIK using two femtosecond lasers to assess differences in protein expression. This was a randomized interventional clinical trial involving 22 patients who underwent femtosecond laser refractive surgery with a contralateral paired eye design. Corneal flaps of 22 subjects were created by either Visumax or Intralase laser. Tear samples were collected preoperatively, and at 1 week and 3 months postoperatively using Schirmer's strips. Tear protein ratios were calculated relative to preoperative protein levels at baseline. The main outcome measures were the levels of a panel of dry eye protein markers analyzed using isobaric tagging for relative and absolute quantitation (iTRAQ) mass spectrometry. A total of 824 unique proteins were quantifiable. Tear protein ratios were differentially regulated between the eyes treated with different lasers. The secretoglobulins Lipophilin A (1.80-fold) and Lipophilin C (1.77) were significantly upregulated (P < 0.05) at 1 week postoperatively in Visumax but not in Intralase-treated eyes. At 1 week, orosomucoid1 was upregulated (1.78) in Intralase but not Visumax-treated eyes. In the same eyes, lysozyme, cathepsin B, and lipo-oxygenase were downregulated at 0.44-, 0.64-, and 0.64-folds, respectively. Transglutaminase-2 was downregulated in both groups of eyes. Different laser platforms induce distinct biological responses in the cornea and ocular surface, which manifests as different levels of tear proteins. This study has implications for surgical technology and modulation of wound healing responses. (ClinicalTrials.gov number, NCT01252654.). Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
Tear Oxygen Under Hydrogel and Silicone Hydrogel Contact Lenses in Humans
Bonanno, Joseph A.; Clark, Christopher; Pruitt, John; Alvord, Larry
2011-01-01
Purpose To determine the tear oxygen tension under a variety of conventional and silicone hydrogel contact lenses in human subjects. Methods Three hydrogel and five silicone hydrogel lenses (Dk/t = 17 to 329) were coated on the back surface with an oxygen sensitive, bovine serum albumin-Pd meso-tetra (4-carboxyphenyl) porphine complex (BSA-porphine). Each lens type was placed on the right eye of 15 non-contact lens wearers to obtain a steady-state open eye tear oxygen tension using oxygen sensitive phosphorescence decay of BSA-porphine. A closed-eye oxygen tension estimate was obtained by measuring the change in tear oxygen tension after 5 min of eye closure. In separate experiments, a goggle was placed over the lens wearing eye and a gas mixture (PO2 = 51 torr) flowed over the lens to simulate anterior lens oxygen tension during eye closure. Results Mean open eye oxygen tension ranged from 58 to 133 torr. Closed eye estimates ranged from 11 to 42 torr. Oxygen tension under the goggle ranged from 8 to 48 torr and was higher than the closed eye estimate for six out of the eight lenses, suggesting that the average closed eye anterior lens surface oxygen tension is <51 torr. For Dk/t >30, the measured tear oxygen tension is significantly lower than that predicted from previous studies. Conclusions The phosphorescence decay methodology is capable of directly measuring the in vivo post lens PO2 of high Dk/t lenses without disturbing the contact lens or cornea. Our data indicate that increasing Dk/t up to and beyond 140 continues to yield increased flux into the central cornea. PMID:19609230
Altered Mucin and Glycoprotein Expression in Dry Eye Disease.
Stephens, Denise N; McNamara, Nancy A
2015-09-01
Mucins are among the many important constituents of a healthy tear film. Mucins secreted and/or associated with conjunctival goblet cells, ocular mucosal epithelial cells, and the lacrimal gland must work together to create a stable tear film. Although many studies have explored the mechanism(s) whereby mucins maintain and protect the ocular surface, the effects of dry eye on the structure and function of ocular mucins are unclear. Here, we summarize current findings regarding ocular mucins and how they are altered in dry eye. We performed a literature review of studies exploring the expression of mucins produced and/or associated with tissues that comprise the lacrimal functional unit and how they are altered in dry eye. We also summarize new insights on the immune-mediated effects of aqueous tear deficiency on ocular surface mucins that we discovered using a mouse model of dry eye. Although consistent decreases in MUC5AC and altered expression of membrane-bound mucins have been noted in both Sjögren and non-Sjögren dry eye, many reports of altered mucins in dry eye are contradictory. Mechanistic studies, including our own, suggest that changes in the glycosylation of mucins rather than the proteins themselves may occur as the direct result of local inflammation induced by proinflammatory mediators, such as interleukin-1. Altered expression of ocular mucins in dry eye varies considerably from study to study, likely attributed to inherent difficulties in analyzing small-volume tear samples, as well as differences in tear collection methods and disease severity in dry eye cohorts. To better define the functional role of ocular mucin glycosylation in the pathogenesis of dry eye disease, we propose genomic and proteomic studies along with biological pathway analysis to reveal novel avenues for exploration.
Evaluation of tear evaporation from ocular surface by functional infrared thermography.
Tan, Jen-Hong; Ng, E Y K; Acharya, U Rajendra
2010-11-01
A novel technique was developed to measure tear evaporation and monitor its variation with respect to time, for the studying of ocular physiology based on dynamic functional infrared thermography and the first law of thermodynamics using the measured ocular surface temperatures (OSTs). This is a noninvasive, noncontact temperature measuring method that is widely applied in the field of biomedicine. A simple method based on the ocular thermal data was proposed to measure the rate of tear evaporation. The OST of 60 normal subjects were recorded in the form of sequential thermal images. For each thermal sequence, the ocular region was selected and warped to a standard form. Thermal data within the regions were processed, on the basis of the first law of thermodynamics to derive the evaporation rate. For elder subjects (aged above 35), the rate was determined to be 55.82 Wm(-2) and for younger subjects, the rate was 58.9 Wm(-2). The corneal rate of evaporation in elder subjects was found statistically (p < 0.11) larger than their younger counterparts. The rate of blinking was observed to be related to the variation of evaporation rate. The authors have measured the evaporation rate on a sequence of thermographic images. A region of interest was selected at first and the same region on all the images were warped into a standard form. Calculations were performed based on the thermal data in those regions to obtain the values of interest. The authors found that the tear evaporation rate for subjects of all age groups was 57.36 +/- 12.73 Wm(-2) and the corneal tear evaporation was higher in elder subjects. The corneal rate of evaporation fluctuated in a larger magnitude in subjects who blinked more than average.
Adsorption of human tear lipocalin to human meibomian lipid films.
Millar, Thomas J; Mudgil, Poonam; Butovich, Igor A; Palaniappan, Chendur K
2009-01-01
Tear lipocalin (Tlc) is a major lipid binding protein in tears and is thought to have an important role in stabilizing the Meibomian lipid layer by transferring lipids to it from the aqueous layer or ocular surface, or by adsorbing to it directly. These possible roles have been investigated in vitro using human Tlc. Tlc was purified from human tears by size exclusion chromatography followed by ion exchange chromatography. Three additional samples of the Tlc were prepared by lipidation, delipidation, and relipidation. The lipids extracted from the purified Tlc were analyzed by HPLC-MS followed by fragmentation. Adsorption of these different forms of Tlc to a human Meibomian lipid film spread on the surface of an artificial tear buffer in a Langmuir trough were observed by recording changes in the pressure with time (Pi-T profile) and monitoring the appearance of the film microscopically. These results were compared with similar experiments using a bovine Meibomian lipid film. The results indicated that Tlc binds slowly to a human Meibomian lipid film compared with lysozyme or lactoferrin, even at 37 degrees C. The adsorption of Tlc to a human Meibomian lipid film was very different from its adsorption to a bovine Meibomian lipid film, indicating the nature of the lipids in the film is critical to the adsorption process. Similarly, the different forms of Tlc had quite distinct adsorption patterns, as indicated both by changes in Pi-T profiles and the microscopic appearance of the films. It was concluded that human Tlc was capable of adsorbing to and penetrating into a Meibomian lipid layer, but this process is very complex and depends on both the types of lipids bound to Tlc and the lipid complement comprising the Meibomian lipid film.
Adsorption of Human Tear Lipocalin to Human Meibomian Lipid Films
Millar, Thomas J.; Mudgil, Poonam; Butovich, Igor A.; Palaniappan, Chendur K.
2009-01-01
Purpose Tear lipocalin (Tlc) is a major lipid binding protein in tears and is thought to have an important role in stabilizing the Meibomian lipid layer by transferring lipids to it from the aqueous layer or ocular surface, or by adsorbing to it directly. These possible roles have been investigated in vitro using human Tlc. Methods Tlc was purified from human tears by size exclusion chromatography followed by ion exchange chromatography. Three additional samples of the Tlc were prepared by lipidation, delipidation, and relipidation. The lipids extracted from the purified Tlc were analyzed by HPLC-MS followed by fragmentation. Adsorption of these different forms of Tlc to a human Meibomian lipid film spread on the surface of an artificial tear buffer in a Langmuir trough were observed by recording changes in the pressure with time (∏-T profile) and monitoring the appearance of the film microscopically. These results were compared with similar experiments using a bovine Meibomian lipid film. Results The results indicated that Tlc binds slowly to a human Meibomian lipid film compared with lysozyme or lactoferrin, even at 37°C. The adsorption of Tlc to a human Meibomian lipid film was very different from its adsorption to a bovine Meibomian lipid film, indicating the nature of the lipids in the film is critical to the adsorption process. Similarly, the different forms of Tlc had quite distinct adsorption patterns, as indicated both by changes in ∏-T profiles and the microscopic appearance of the films. Conclusions It was concluded that human Tlc was capable of adsorbing to and penetrating into a Meibomian lipid layer, but this process is very complex and depends on both the types of lipids bound to Tlc and the lipid complement comprising the Meibomian lipid film. PMID:18757516
Nakajima, T; Walkup, R D; Tochigi, A; Shearer, T R; Azuma, M
2007-11-01
Lacritin is a mitogen of human salivary gland cells as well as a stimulator of human corneal epithelial cells. It is expected to be an important factor in maintaining the surrounding ocular surface. The monkey would be a relevant animal model in which to study the role of lacritin in ophthalmic physiology and pathology. However, to our knowledge, no cDNA cloning or functional analysis of monkey lacritin has been performed. Thus, the purposes of this study were: (1) to clone the monkey ortholog of lacritin; (2) to characterize lacritin in tears from several species; and (3) to determine the tissues where lacritin is produced and secreted. cDNA for lacritin from rhesus macaque contained 547 bp, with 411 bp in an open reading frame (ORF) encoding a protein of 137 amino acids. Monkey lacritin showed 89% amino acid homology with human lacritin; one amino acid was deleted in all three monkey strains. The predicted MW of mature lacritin was 12.2 kDa, and the isoelectric point was 4.99. Lacritin showed anomalous migration at approximately 21.0 kDa on SDS-PAGE, as confirmed by immunoblotting and amino acid sequencing. Similar to native lacritin in monkey tears, a 21 kDa band was also detected in human tears. In contrast, no lacritin was observed at a similar position on SDS-PAGE in rat, rabbit and dog tears. In the monkey, lacritin mRNA was expressed highly in the lacrimal gland, moderately in the conjunctiva and the meibomian gland, and weakly in corneal epithelium. In primates, lacritin was produced in the lacrimal gland and secreted into tear fluid. These results suggest that lacritin might be important for the maintenance of the ocular surface in higher animals, such as monkeys and humans.
Adsorption of apo- and holo-tear lipocalin to a bovine Meibomian lipid film.
Mudgil, Poonam; Millar, Thomas J
2008-04-01
Adsorption of apo- and holo-tear lipocalin (Tlc) to bovine Meibomian lipid film was studied. A Langmuir trough was used for these studies and the adsorption of protein was observed by recording changes in the pressure with time (pi-T profile). The films were photographed at different stages of adsorption by doping Meibomian lipids with a fluorescently tagged lipid. The results indicated that apo-Tlc adsorbed much more quickly than holo-Tlc to the Meibomian lipid film. Contrary to the expectation that holo-Tlc would release lipids to the surface and surface pressure would be higher, it was found that the surface pressure was higher with the adsorption of apo-Tlc to the surface. Photography of the films showed that apo- and holo-Tlc interacted differently with the Meibomian lipid layer. Adsorption of holo-Tlc resulted in big bright patches and adsorption of apo-Tlc resulted in many small patches along with the big patches. Both forms of Tlc produced a more stable film as indicated by decreased movement of the protein adsorbed films, and a higher maximum surface pressure upon compression of these films compared with Meibomian lipid films alone. Isocyles of apo-Tlc adsorbed films gave a higher surface pressure than that of holo-Tlc. From these results, it is concluded that both apo- and holo-Tlc adsorbed to the Meibomian lipid layer and the delivery of the lipids from Tlc to the outer lipid layer could not be detected by our techniques. Its scavenging role to remove lipids from the corneal surface and bind with them might be beneficial for increasing tear viscosity but whether those lipids are delivered to the outermost lipid layer still remains unclear.
Brockmeyer, Matthias; Schmitt, Cornelia; Haupert, Alexander; Kohn, Dieter; Lorbach, Olaf
2017-12-01
The reliable diagnosis of partial-thickness tears of the rotator cuff is still elusive in clinical practise. Therefore, the purpose of the study was to determine the diagnostic accuracy of MR imaging and clinical tests for detecting partial-thickness tears of the rotator cuff as well as the combination of these parameters. 334 consecutive shoulder arthroscopies for rotator cuff pathologies performed during the time period between 2010 and 2012 were analyzed retrospectively for the findings of common clinical signs for rotator cuff lesions and preoperative MR imaging. These were compared with the intraoperative arthroscopic findings as "gold standard". The reports of the MR imaging were evaluated with regard to the integrity of the rotator cuff. The Ellman Classification was used to define partial-thickness tears of the rotator cuff in accordance with the arthroscopic findings. Descriptive statistics, sensitivity, specificity, positive and negative predictive value were calculated. MR imaging showed 80 partial-thickness and 70 full-thickness tears of the rotator cuff. The arthroscopic examination confirmed 64 partial-thickness tears of which 52 needed debridement or refixation of the rotator cuff. Sensitivity for MR imaging to identify partial-thickness tears was 51.6%, specificity 77.2%, positive predictive value 41.3% and negative predictive value 83.7%. For the Jobe-test, sensitivity was 64.1%, specificity 43.2%, positive predictive value 25.9% and negative predictive value 79.5%. Sensitivity for the Impingement-sign was 76.7%, specificity 46.6%, positive predictive value 30.8% and negative predictive value 86.5%. For the combination of MR imaging, Jobe-test and Impingement-sign sensitivity was 46.9%, specificity 85.4%, positive predictive value 50% and negative predictive value 83.8%. The diagnostic accuracy of MR imaging and clinical tests (Jobe-test and Impingement-sign) alone is limited for detecting partial-thickness tears of the rotator cuff. Additionally, the combination of MR imaging and clinical tests does not improve diagnostic accuracy. Level II, Diagnostic study.
Zoukhri, Driss
2011-01-01
The non-keratinized epithelia of the ocular surface are constantly challenged by environmental insults, such as smoke, dust, and airborne pathogens. Tears are the sole physical protective barrier for the ocular surface. Production of tears in inadequate quantity or of inadequate quality results in constant irritation of the ocular surface, leading to dry eye disease, also referred to as keratoconjunctivitis sicca (KCS). Inflammation of the lacrimal gland, such as occurs in Sjögren’s syndrome, sarcoidosis, chronic graft versus-host disease, and other pathological conditions, results in inadequate secretion of the aqueous layer of the tear film, and is a leading cause of dry eye disease. The hallmarks of lacrimal gland inflammation are the presence of immune cell infiltrates, loss of acinar epithelial cells (the secreting cells), and increased production of proinflammatory cytokines. To date, the mechanisms leading to acinar cell loss and the associated decline in lacrimal gland secretion are still poorly understood. It is also not understood why the remaining lacrimal gland cells are unable to proliferate in order to regenerate a functioning lacrimal gland. This article reviews recent advances in exocrine tissue injury and repair, with emphasis on the roles of programmed cell death and stem/progenitor cells. PMID:20427009
Exploring the Predisposition of the Asian Eye to Development of Dry Eye.
Craig, Jennifer P; Wang, Michael T M; Kim, Dabin; Lee, Jung Min
2016-07-01
To investigate the influence of eyelid shape on tear film quality, ocular surface characteristics and dry eye symptomatology by comparing Asian and Caucasian populations. Seventy-four age-matched participants were recruited in a cross-sectional study. Participants were classified into Asian single lid (ASL), Asian double lid (ADL), and Caucasian double lid (CDL) groups. Dry eye symptomatology, ocular surface characteristics, and tear film quality were evaluated in a single clinical session. Meibomian gland dropout was significantly greater in both the ASL and ADL groups than in the CDL group (all P<.05). A greater proportion of ASL and ADL participants exhibited incomplete blinking than CDL patients (all P<.05). There were no significant differences in tear film quality and dry eye symptomatology between the three groups (all P>.05). Exposed ocular surface area, lissamine green staining, and lid wiper epitheliopathy were significantly greater in the ADL group compared to the CDL group (all P<.05). The CDL group displayed significantly greater anterior blepharitis and lid telangiectasia grades compared to both ASL and ADL groups (all P<.05). A higher degree of meibomian gland dropout and incomplete blinking was observed in both Asian groups compared to the Caucasian group, potentially predisposing these groups to dry eye. Copyright © 2016 Elsevier Inc. All rights reserved.
Therapeutic targets in dry eye syndrome.
Peral, Assumpta; Domínguez-Godínez, Carmen O; Carracedo, Gonzalo; Pintor, Jesús
2008-04-01
Dry eye is a multifactorial disease of the tears and the ocular surface that manifests with a wide variety of signs and symptoms. It is prevalent in about 33% of the population worldwide. Due to the importance of the pathology, new tests, drugs and technologies have been developed to assist the diagnosis, management and follow-up of the disease. Current available therapies try to alleviate symptoms and to reduce signs in order to restore the ocular surface. Depending on the etiology of the pathology it is possible to use lubricants, secretagogues, biological tear substitutes or antiinflammatory drugs, either independently or combined. Nowadays, the therapies under clinical trial are devoted to stimulating tear components (e.g., diquafosol, a P2Y receptor agonist), or mucin secretion (e.g., rebamipide, an amino acid analogue of quinolinone). Others include gefarnate, a water-insoluble terpene fatty acid that contributes to restoring mucins on the ocular surface, or cevimeline, an oral cholinergic agonist that reduces the symptoms associated with dry eye. Other potential compounds described in patents are in a lower phase of drug development. These compounds come from different families of therapies, and among others, can be found in the form of steroidal and nonsteroidal antiinflammatory agents, vitamins A and D, neurotransmitters and neuropeptides. Copyright 2008 Prous Science, S.A.U. or its licensors. All rights reserved.
Influence of asymmetric magnetic perturbation on the nonlinear evolution of double tearing modes
NASA Astrophysics Data System (ADS)
Xiong, G. Z.; Wang, L.; Li, X. Q.; Liu, H. F.; Tang, C. J.; Huang, J.; Zhang, X.; Wang, X. Q.
2017-06-01
The effects of asymmetric magnetic perturbation on the triggering and evolution of double tearing modes (DTMs) are investigated using nonlinear magnetohydrodynamics simulations in a slab geometry. We find that for reversed magnetic shear plasmas the resistive reconnection process induced by the initial perturbation at one rational surface can drive a new island at the other rational surface with the same mode number. The four typical states of the mode for the time evolution are found, and include: (i) a linear growth stage; (ii) a linear/nonlinear stable stage; (iii) an interactively driving stage; and (iv) a symmetric DTM stage. These differ from previous simulation results. Moreover, nonlinear DTM growth is found to strongly depend on the asymmetric magnetic perturbation, particularly in the early nonlinear phase. The initial perturbation strength scale of island width suggests that the left island enters into a Sweet-Parker growth process when the right island is sufficiently large to effectively drive the other. These results predict that although externally applied magnetic perturbations can suppress the neoclassical tearing mode they can also trigger new instabilities such as asymmetric DTMs.
Miswan, Mohd Fairudz Bin Mohd; Saman, Mohd Shahril Bin Ahmad; Hui, Teo Seow; Al-Fayyadh, Mohamed Zubair Mohamed; Ali, Mohamed Razif Bin Mohamed; Min, Ng Wuey
2017-01-01
We conducted a study to elucidate the correlation between the anatomy of the shoulder joint with the development of rotator cuff tear (RCT) and glenohumeral osteoarthritis (GHOA) by using acromioglenoid angle (AGA). The AGA is a new measured angle formed between the line from midglenoid to lateral end of the acromion with the line parallel to the glenoid surface. The AGA was measured in a group of 85 shoulders with RCT, 49 with GHOA and 103 non-RCT/GHOA control shoulders. The AGA was compared with other radiological parameters, such as, the critical shoulder angle (CSA), the acromion index (AI) and the acromiohumeral interval (AHI). Correlational and regression analysis were performed using SPSS 20. The mean AGA was 50.9° (45.2-56.5°) in the control group, 53.3° (47.6-59.1°) in RCT group and 45.5° (37.7-53.2°) in OA group. Among patients with AGA > 51.5°, 61% were in the RCT group and among patients with AGA < 44.5°, 56% were in OA group. Pearson correlation analysis had shown significant correlation between AGA and CSA ( r = 0.925, p < 0.001). It was also significant of AHI in RCT group with mean 6.6 mm (4.7-8.5 mm) and significant AI in OA group with mean 0.68 (0.57-0.78) with p value < 0.001 respectively. The AGA method of measurement is an excellent predictive parameter for diagnosing RCT and GHOA.
Chung, So-Hyang; Lim, Sung A; Tchach, Hungwon
2016-02-01
To evaluate the efficacy and safety profile of carbomer-based lipid-containing artificial tear formulations (CBLAT) in patients with dry eye syndrome. A multicenter parallel-group study was conducted in 412 patients with dry eye syndrome. Of these patients, 221 switched from using artificial tears to CBLAT (switching group) and 191 added CBLAT to their current treatment (add-on group). Ocular symptom scores, ocular staining grades, tear film breakup time (tBUT), Schirmer I test value, and Korean dry eye level (as defined by the Korean Corneal Disease Study Group guidelines) were evaluated at baseline and after 4 weeks of treatment. After 4 weeks of treatment, ocular surface staining grade, tBUT, Schirmer I value, ocular irritation symptom scores, and the positive rate of visual symptom improved significantly in both groups. Mean reductions in ocular surface staining grades (-0.8 ± 0.9) and ocular irritation symptom scores (-0.8 ± 0.8) in the add-on group were significantly higher than those (-0.5 ± 0.8 and -0.6 ± 0.8) in the switching group (P < 0.01 and P < 0.05). The positive rate of visual symptoms (44.2%) in the add-on group was significantly higher than that (26.4%) in the switching group (P < 0.01). The decrease of Korean dry eye level was 30.1% in the switching group and 51.6% in the add-on group. More patients in the add-on group had decreased dry eye levels than those in the switching group (P < 0.0001). CBLAT improves ocular surface staining grades, tBUT, Schirmer I values, and ocular symptoms in patients with dry eye syndrome.
Igarashi, Akihito; Kamiya, Kazutaka; Kobashi, Hidenaga; Shimizu, Kimiya
2015-08-01
To assess the changes in intraocular scattering before and after instillation of rebamipide ophthalmic suspension in patients with dry eye after corneal refractive surgery. This study enrolled 60 eyes of 30 dry eye patients undergoing corneal refractive surgery. Patients were randomly assigned to start topical administration of rebamipide ophthalmic suspension (rebamipide group) or artificial tears (control group) 4 times daily for 4 weeks. Tear secretion, tear break-up time (TBUT), and the fluorescein score were measured before and after treatment. Intraocular light scattering was also measured as the objective scattering index (OSI) at 0.5-second intervals over 10 seconds. In the rebamipide group, the Schirmer I test, TBUT, and fluorescein score improved significantly, from 11.4 ± 9.0 mm, 2.2 ± 0.7 seconds, and 4.3 ± 1.3 to 14.9 ± 7.4 mm, 4.5 ± 1.7 seconds, and 1.9 ± 1.0, respectively (P = 0.006, P < 0.001, P < 0.001, Wilcoxon signed rank test). We found significant improvements in OSI at 5.0 to 10.0 seconds after blinking (5-8 seconds, P = 0.01; 9 seconds, P = 0.02; 10 seconds, P < 0.001). The mean OSI, the OSI change rate, and the OSI slope of the linear regression line improved significantly, from 2.73 ± 1.52, 74.7 ± 69.5%, and 0.10 ± 0.12 to 2.19 ± 1.19, 28.6 ± 48.7%, and 0.04 ± 0.08, respectively (P = 0.02, 0.003, and 0.03). Rebamipide ophthalmic suspension was effective for improving both ocular surface parameters and optical quality in patients with dry eye undergoing corneal refractive surgery, suggesting that it may hold promise for the treatment of such patients.
Level-set simulations of soluble surfactant driven flows
NASA Astrophysics Data System (ADS)
Cleret de Langavant, Charles; Guittet, Arthur; Theillard, Maxime; Temprano-Coleto, Fernando; Gibou, Frédéric
2017-11-01
We present an approach to simulate the diffusion, advection and adsorption-desorption of a material quantity defined on an interface in two and three spatial dimensions. We use a level-set approach to capture the interface motion and a Quad/Octree data structure to efficiently solve the equations describing the underlying physics. Coupling with a Navier-Stokes solver enables the study of the effect of soluble surfactants that locally modify the parameters of surface tension on different types of flows. The method is tested on several benchmarks and applied to three typical examples of flows in the presence of surfactant: a bubble in a shear flow, the well-known phenomenon of tears of wine, and the Landau-Levich coating problem.
Pérez-Balbuena, Ana L; Ochoa-Tabares, Juan C; Belalcazar-Rey, Sandra; Urzúa-Salinas, Cristian; Saucedo-Rodríguez, Laura R; Velasco-Ramos, Regina; Suárez-Sánchez, Raúl G; Rodríguez-Carrizalez, Adolfo D; Oregón-Miranda, Aldo A
2016-09-20
Dry eye disease (DED) is multifactorial, affecting 5-34 % of the global adult population and reducing quality of life. The artificial tears or lubricants are the therapy most used for the treatment of DED, due to their low side effect profile, which attempt to modify the properties of the tear film. The aim of the present study was to evaluate the clinical efficacy of a fixed combination of xanthan gum and chondroitin sulfate preservative free on the ocular surface of patients with dry eye disease during 60 days of intervention. A phase III, double-blind, masked, controlled, multicenter, clinical trial of 148 subjects, randomized to either a fixed combination of xanthan gum 0.09 % and chondroitin sulfate 0.1 % (XG/CS) ophthalmic solution (n = 76) or a fixed combination of polyethylene glycol 400 0.4 % and propylene glycol 0.3 % (PEG/PG) (n = 72). Subjects self-dosed four times daily during 60 days. Follow-up was set on days 2, 7, 15, 30 and 60. Assessments of anterior/posterior segment ocular signs were performed. The outcome measures included Schirmer test, tear film break-up time and OSDI score. Security variables included intraocular pressure, lisamine green and fluorescein ocular surface stains. The primary efficacy endpoints were similar between groups at baseline. After intervention time Schirmer test increased in both groups compared to baseline, XG/CS (6.4 ± 2.2 vs 11.0 ± 6.6; p = 0.002) and PEG/PG (6.5 ± 2.5 vs 10.5 ± 5.6; p = 0.019) respectively. Similar results were reported in the tear film break-up time in XG/CS (5.5 ± 2.1 vs 7.4 ± 2.9; p = 0.027) and PEG/PG (5.2 ± 2.0 vs 7.4 ± 2.7; p = 0.046) respectively. The OSDI score decreased to normal values in both groups, XG/CS (19.3 ± 7.4 vs 7.3 ± 5.9; p = 0.001) and PEG/PG (19.3 ± 7.5 vs 7.9 ± 8.2; p = 0.001) respectively. There was no significant difference between treatments for any parameter. Moreover, both groups decreased the presence of burning sensation, tearing, foreign body sensation, conjunctival hyperemia and photophobia. The adverse events were not related to the interventions. Xanthan gum/chondroitin sulfate preservative free showed similar clinical efficacy, evaluated with OSDI score, TBUT and Schirmer test compared to polyethylene glycol/propylene glycol in the treatment of dry eye disease. ClinicalTrials.gov: NCT01657253 . Date of registration May 19, 2014.
Odum, J.K.; Stephenson, W.J.; Shedlock, K.M.; Pratt, T.L.
1998-01-01
The February 7, 1812, New Madrid, Missouri, earthquake (M [moment magnitude] 8) was the third and final large-magnitude event to rock the northern Mississippi Embayment during the winter of 1811-1812. Although ground shaking was so strong that it rang church bells, stopped clocks, buckled pavement, and rocked buildings up and down the eastern seaboard, little coseismic surface deformation exists today in the New Madrid area. The fault(s) that ruptured during this event have remained enigmatic. We have integrated geomorphic data documenting differential surficial deformation (supplemented by historical accounts of surficial deformation and earthquake-induced Mississippi River waterfalls and rapids) with the interpretation of existing and recently acquired seismic reflection data, to develop a tectonic model of the near-surface structures in the New Madrid, Missouri, area. This model consists of two primary components: a northnorthwest-trending thrust fault and a series of northeast-trending, strike-slip, tear faults. We conclude that the Reelfoot fault is a thrust fault that is at least 30 km long. We also infer that tear faults in the near surface partitioned the hanging wall into subparallel blocks that have undergone differential displacement during episodes of faulting. The northeast-trending tear faults bound an area documented to have been uplifted at least 0.5 m during the February 7, 1812, earthquake. These faults also appear to bound changes in the surface density of epicenters that are within the modern seismicity, which is occurring in the stepover zone of the left-stepping right-lateral strike-slip fault system of the modern New Madrid seismic zone.
Wylie, James D; Suter, Thomas; Potter, Michael Q; Granger, Erin K; Tashjian, Robert Z
2016-02-17
Patient-reported outcome measures have increasingly accompanied objective examination findings in the evaluation of orthopaedic interventions. Our objective was to determine whether a validated measure of mental health (Short Form-36 Mental Component Summary [SF-36 MCS]) or measures of tear severity on magnetic resonance imaging were more strongly associated with self-assessed shoulder pain and function in patients with symptomatic full-thickness rotator cuff tears. One hundred and sixty-nine patients with full-thickness rotator cuff tears were prospectively enrolled. Patients completed the Short Form-36, visual analog scales for shoulder pain and function, the Simple Shoulder Test (SST), and the American Shoulder and Elbow Surgeons (ASES) instrument at the time of diagnosis. Shoulder magnetic resonance imaging examinations were reviewed to document the number of tendons involved, tear size, tendon retraction, and tear surface area. Age, sex, body mass index, number of medical comorbidities, smoking status, and Workers' Compensation status were recorded. Bivariate correlations and multivariate regression models were calculated to identify associations with baseline shoulder scores. The SF-36 MCS had the strongest correlation with the visual analog scale for shoulder pain (Pearson correlation coefficient, -0.48; p < 0.001), the visual analog scale for shoulder function (Pearson correlation coefficient, -0.33; p < 0.001), the SST (Pearson correlation coefficient, 0.37; p < 0.001), and the ASES score (Pearson correlation coefficient, 0.51; p < 0.001). Tear severity only correlated with the visual analog scale for shoulder function; the Pearson correlation coefficient was 0.19 for tear size (p = 0.018), 0.18 for tendon retraction (p = 0.025), 0.18 for tear area (p = 0.022), and 0.20 for the number of tendons involved (p = 0.011). Tear severity did not correlate with other scores in bivariate correlations (all p > 0.05). In all multivariate models, the SF-36 MCS had the strongest association with the visual analog scale for shoulder pain, the visual analog scale for shoulder function, the SST, and the ASES score (all p < 0.001). Patient mental health may play an influential role in patient-reported pain and function in patients with full-thickness rotator cuff tears. Further studies are needed to determine its effect on the outcome of the treatment of rotator cuff disease. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.
Hori, Yuichi; Kageyama, Tomofumi; Sakamoto, Asuka; Shiba, Tomoaki; Nakamura, Masatsugu; Maeno, Takatoshi
To investigate the short-term effects of 2 new secretagogue eye drops for dry eye, 3% diquafosol tetrasodium ophthalmic solution (diquafosol) and 2% rebamipide ophthalmic suspension (rebamipide), on the concentration of mucin 5AC (MUC5AC) in rabbit tear fluid and conjunctival goblet cells. One dose of artificial tears, diquafosol or rebamipide, was instilled into 8 eyes of Japanese white rabbits. MUC5AC concentration in the tear fluid was examined using the enzyme-linked immunosorbent assay 15 min after instillation and compared with 8 untreated controls. Impression cytology was performed to measure the number of periodic acid Schiff (PAS)-positive cells and the ratio of the PAS-positive area using image analysis software. Statistical comparison was performed using ANOVA with post hoc analysis with the Tukey's test. After 15 min, only diquafosol significantly (P ≤ 0.01) increased the MUC5AC level in the tear fluid. Although no drug affected the number of PAS-positive cells, the ratio of the PAS-positive area decreased significantly (P ≤ 0.01) only in the diquafosol group. These data indicated that more PAS-positive MUC5AC was released into the tear fluid from the goblet cells by diquafosol than by rebamipide. There is a difference in the induction pattern of MUC5AC into the tears from the goblet cells between these eye drops.
Hand-assisted laparoscopic repair of a grade IV rectal tear in a postparturient mare.
Stewart, Suzanne G; Johnston, Janet K; Parente, Eric J
2014-10-01
An 8-year-old multiparous Thoroughbred broodmare was admitted for evaluation of a rectal tear sustained during parturition. On initial evaluation, the mare had mild signs of abdominal discomfort. A full-thickness rectal tear located 30 cm cranial to the anus and extending approximately 15 cm longitudinally along the surface of the small colon between the 4 and 6 o'clock positions, when viewed from behind, was diagnosed on examination per rectum. Laparoscopic evaluation of the abdomen was performed to assess the tear and extent of peritoneal contamination. A hand-assisted repair via a flank incision was performed. The tear was closed in a single-layer, simple continuous pattern with size-0 polydioxanone with a handheld needle holder. Subsequently, a ventral midline celiotomy was performed, and intestinal contents were evacuated via a pelvic flexure enterotomy and a typhlotomy. Following surgery, the mare was managed with IV fluid therapy, partial parenteral nutrition, antimicrobials, and NSAIDs for 5 to 7 days before being gradually reintroduced to a complete pelleted feed and alfalfa hay. Prior to discharge, examination per rectum revealed no stricture formation associated with repair. The mare was discharged from the hospital and performed successfully as a broodmare, with the delivery of a live foal 1 year after surgery. Successful repair with an excellent outcome was achieved in this mare. Hand-assisted laparoscopic repair should be considered as a possible treatment option in horses with grade IV rectal tears.
Chesnokova, N B; Beznos, O V; Lozinskaya, N A; Beyshenova, G A; Nesterova, T V
2016-01-01
Acute immunogenic uveitis was modeled in rabbits via the subcutaneous and intravitreal injections of normal horse serum. We studied the effect of instillations of 0.1% melatonin solution on the clinical course of uveitis and biochemical parameters of tear fluid and aqueous humor: antioxi-dant activity, protein concentration and α(2)-macroglobulin level. Melatonin instillations decreased clinical manifestations of uveitis. We found that the antioxidant activity in tears of the rabbits treated with melatonin was substantially higher and the α(2)-macroglobulin level lower than in untreated animals. Antioxidant activity in aqueous humor taken on day 10 of uveitis was also twice higher while protein and α(2)-macroglobulin levels were 1.5-2 times lower than in untreated animals. These data indicate that instillations of melatonin increase the local antioxidant activity and decrease the acuity of inflammation and permeability of hematoophthalmic barrier in uveitis.
Water-evaporation reduction by duplex films: application to the human tear film.
Cerretani, Colin F; Ho, Nghia H; Radke, C J
2013-09-01
Water-evaporation reduction by duplex-oil films is especially important to understand the physiology of the human tear film. Secreted lipids, called meibum, form a duplex film that coats the aqueous tear film and purportedly reduces tear evaporation. Lipid-layer deficiency is correlated with the occurrence of dry-eye disease; however, in-vitro experiments fail to show water-evaporation reduction by tear-lipid duplex films. We review the available literature on water-evaporation reduction by duplex-oil films and outline the theoretical underpinnings of spreading and evaporation kinetics that govern behavior of these systems. A dissolution-diffusion model unifies the data reported in the literature and identifies dewetting of duplex films into lenses as a key challenge to obtaining significant evaporation reduction. We develop an improved apparatus for measuring evaporation reduction by duplex-oil films including simultaneous assessment of film coverage, stability, and temperature, all under controlled external mass transfer. New data reported in this study fit into the larger body of work conducted on water-evaporation reduction by duplex-oil films. Duplex-oil films of oxidized mineral oil/mucin (MOx/BSM), human meibum (HM), and bovine meibum (BM) reduce water evaporation by a dissolution-diffusion mechanism, as confirmed by agreement between measurement and theory. The water permeability of oxidized-mineral-oil duplex films agrees with those reported in the literature, after correction for the presence of mucin. We find that duplex-oil films of bovine and human meibum at physiologic temperature reduce water evaporation only 6-8% for a 100-nm film thickness pertinent to the human tear film. Comparison to in-vivo human tear-evaporation measurements is inconclusive because evaporation from a clean-water surface is not measured and because the mass-transfer resistance is not characterized. Copyright © 2013 Elsevier B.V. All rights reserved.
Rapamycin Eye Drops Suppress Lacrimal Gland Inflammation In a Murine Model of Sjögren's Syndrome
Shah, Mihir; Edman, Maria C.; Reddy Janga, Srikanth; Yarber, Frances; Meng, Zhen; Klinngam, Wannita; Bushman, Jonathan; Ma, Tao; Liu, Siyu; Louie, Stan; Mehta, Arjun; Ding, Chuanqing; MacKay, J. Andrew; Hamm-Alvarez, Sarah F.
2017-01-01
Purpose To evaluate the efficacy of topical rapamycin in treating autoimmune dacryoadenitis in a mouse model of Sjögren's syndrome. Methods We developed rapamycin in a poly(ethylene glycol)-distearoyl phosphatidylethanolamine (PEG-DSPE) micelle formulation to maintain solubility. Rapamycin or PEG-DSPE eye drops (vehicle) were administered in a well-established Sjögren's syndrome disease model, the male nonobese diabetic (NOD) mice, twice daily for 12 weeks starting at 8 weeks of age. Mouse tear fluid was collected and tear Cathepsin S, a putative tear biomarker for Sjögren's syndrome, was measured. Lacrimal glands were retrieved for histological evaluation, and quantitative real-time PCR of genes associated with Sjögren's syndrome pathogenesis. Tear secretion was measured using phenol red threads, and corneal fluorescein staining was used to assess corneal integrity. Results Lymphocytic infiltration of lacrimal glands from rapamycin-treated mice was significantly (P = 0.0001) reduced by 3.8-fold relative to vehicle-treated mice after 12 weeks of treatment. Rapamycin, but not vehicle, treatment increased tear secretion and decreased corneal fluorescein staining after 12 weeks. In rapamycin-treated mice, Cathepsin S activity was significantly reduced by 3.75-fold in tears (P < 0.0001) and 1.68-fold in lacrimal gland lysates (P = 0.003) relative to vehicle-treated mice. Rapamycin significantly altered the expression of several genes linked to Sjögren's syndrome pathogenesis, including major histocompatibility complex II, TNF-α, IFN-γ, and IL-12a, as well as Akt3, an effector of autophagy. Conclusions Our findings suggest that topical rapamycin reduces autoimmune-mediated lacrimal gland inflammation while improving ocular surface integrity and tear secretion, and thus has potential for treating Sjögren's syndrome–associated dry eye. PMID:28122086
Jee, Donghyun; Park, Sang Hee; Kim, Man Soo; Kim, Eun Chul
2014-07-03
To compare the antioxidant and inflammatory cytokine activities in tears of patients with dry eye syndrome treated with preservative-free versus preserved eye drops. A total of 100 patients with moderate to severe dry eye syndrome were randomly divided into two groups. Fifty patients (group 1) were treated four times with preservative-free 0.1% sodium hyaluronate and 0.1% fluorometholone eye drops in the first month and with preservative-free 0.1% sodium hyaluronate and 0.05% cyclosporine eye drops in the second and third months. Another 50 patients (group 2) were treated with preserved eye drops on the same schedule. Ocular Surface Disease Index, corneal fluorescein staining, Schirmer I test, tear film breakup time, impression cytology, and antioxidant and inflammatory cytokine activities in tears were evaluated. Treatment with preservative-free eye drops led to significant improvements in symptoms, tear film breakup time, Schirmer I score, and impression cytologic findings compared to treatment with preserved eye drops (P < 0.05) in patients with dry eye syndrome. There was a statistically significant decrease in the IL-1β, IL-6, IL-12, and TNF-α concentrations and a statistically significant increase in the catalase, peroxiredoxin 2, superoxide dismutase 2 (SOD 2), and thioredoxin mean fluorescence intensity (MFI) of tears in the preservative-free group at 1, 2, and 3 months compared to initial values, respectively (P < 0.05). Treatment with preservative-free eye drops is effective against the dry eye syndrome. Preservative-free eye drops seem to be more effective than preserved eye drops in decreasing ocular inflammation and in increasing antioxidant contents in tears of patients with dry eye syndrome. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
Hirata, Harumitsu; Rosenblatt, Mark I
2014-08-19
Tear hyperosmolarity is a ubiquitous feature of dry-eye disease. Although dry-eye patients' sensitivity to cooling is well known, the effects of tear hyperosmolarity on a small amount of cooling in the corneal nerves have not been quantitatively examined. Recently reported corneal afferents, high-threshold cold sensitive plus dry-sensitive (HT-CS + DS) neurons, in rats is normally excited by strong (>4°C) cooling of the cornea, which, when applied to healthy humans, evokes the sensation of discomfort. However, corneal cooling measured between blinks does not exceed 2°C normally. Thus, we sought to determine if these nociceptors could be sensitized by hyperosmolar tears such that they are now activated by small cooling of the ocular surface. Trigeminal ganglion neurons innervating the cornea were extracellularly recorded in isoflurane-anesthetized rats. The responses of single corneal neurons to cooling stimuli presented in the presence of hyperosmolar (350-800 mOsm NaCl) tears were examined. The HT-CS + DS neurons with thresholds averaging 4°C cooling responded to cooling stimuli presented after 15 minutes of hyperosmolar tears with thresholds of less than 1°C. The response magnitudes also were enhanced so that the responses to small (2°C) cooling emerged, where none was observed before. These results demonstrate that after exposure to hyperosmolar tears, these nociceptive corneal neurons now begin to respond to the slight cooling normally encountered between blinks, enabling the painful information to be carried to the brain, which could explain the cooling-evoked discomfort in dry eye patients. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
Clinical utility of 3% diquafosol ophthalmic solution in the treatment of dry eyes
Koh, Shizuka
2015-01-01
Diquafosol is a drug used for dry eye treatment with a novel mechanism of action. It stimulates the secretion of tear fluid and mucin on the ocular surface, thus enabling us to selectively treat the tear film layer, playing an important role in the establishment of the concept of “Tear Film Oriented Therapy (TFOT)”, an effective therapeutic approach to dry eye in Japan. The 3% diquafosol ophthalmic solution has been widely used for the treatment of dry eye in clinical practice, and it is currently available in Japan and South Korea. This review provides an overview of the clinical utility of 3% diquafosol ophthalmic solution, focusing on the results of clinical studies on various types of dry eye, including aqueous-deficient dry eye, short tear film breakup time-type dry eye, and post dry eye after laser in situ keratomileusis. It also introduces the additive effect of diquafosol on sodium hyaluronate monotherapy for dry eye, and the effect of 3% diquafosol ophthalmic solution for dry eye-related conditions. Additionally, it summarizes the ocular effects of diquafosol in healthy human eyes. Lastly, the importance of improving tear film stability in dry eye treatment, as well as general advances in dry eye treatments, are described. PMID:26028958
Clinical utility of 3% diquafosol ophthalmic solution in the treatment of dry eyes.
Koh, Shizuka
2015-01-01
Diquafosol is a drug used for dry eye treatment with a novel mechanism of action. It stimulates the secretion of tear fluid and mucin on the ocular surface, thus enabling us to selectively treat the tear film layer, playing an important role in the establishment of the concept of "Tear Film Oriented Therapy (TFOT)", an effective therapeutic approach to dry eye in Japan. The 3% diquafosol ophthalmic solution has been widely used for the treatment of dry eye in clinical practice, and it is currently available in Japan and South Korea. This review provides an overview of the clinical utility of 3% diquafosol ophthalmic solution, focusing on the results of clinical studies on various types of dry eye, including aqueous-deficient dry eye, short tear film breakup time-type dry eye, and post dry eye after laser in situ keratomileusis. It also introduces the additive effect of diquafosol on sodium hyaluronate monotherapy for dry eye, and the effect of 3% diquafosol ophthalmic solution for dry eye-related conditions. Additionally, it summarizes the ocular effects of diquafosol in healthy human eyes. Lastly, the importance of improving tear film stability in dry eye treatment, as well as general advances in dry eye treatments, are described.
Ueta, Mayumi; Shoji, Jun; Sotozono, Chie; Kinoshita, Shigeru
2014-01-01
Rebamipide eyedrops are approved in Japan for the treatment of dry eye disease. Some patients with allergic conjunctival diseases also manifest dry eye. Earlier we reported that rebamipide suppressed polyI:C-induced inflammatory cytokines in human conjunctival epithelial cells. In the current study we examined the effect of rebamipide eyedrops on the level of interleukin-8 (IL-8), eosinophil cationic protein (ECP), and total IgE on the ocular surface. We prescribed rebamipide eyedrops to patients with atopic keratoconjunctivitis (AKC) who presented with dry eye (6 eyes in 4 AKC patients) and measured the IL-8, ECP, and total IgE levels in their tears before- and 2, and 4-6 weeks after the start of rebamipide treatment. To measure the IL-8 and total IgE levels in their tears we used BD™ CBA Flex sets; ECP measurements were with ELISA. The level of IL-8, ECP, and total IgE in the tears of AKC patients was reduced significantly 4-6 weeks after the start of rebamipide treatment. We also recorded subjective symptoms associated with AKC, e.g. itching, foreign body sensation, and eye mucus discharge, by using a patient questionnaire. Their subjective symptoms associated with AKC were also significantly ameliorated at 2 and 4-6 weeks. Our observations suggest that the anti-inflammatory effects of rebamipide eyedrops help to combat human ocular surface inflammation and that they may be a new effective therapy in patients with AKC.
García-Posadas, Laura; Contreras-Ruiz, Laura; López-García, Antonio; Villarón Álvarez, Sonia; Maldonado, Miguel J; Diebold, Yolanda
2012-02-01
The purpose of this study was to demonstrate the presence of the receptor for hyaluronan-mediated motility (RHAMM) in human conjunctival epithelium and in two widely used cell lines from human corneal (HCE) and conjunctival (IOBA-NHC) epithelia. We compared the distribution of RHAMM proteins and mRNAs in human ocular surface tissues (corneal, limbal and conjunctival), HCE and IOBA-NHC cell lines, and corneal and conjunctival epithelia primary samples from healthy donors with the previously identified hyaluronan receptor CD44. We also aimed to determine if soluble CD44 (sCD44) was present in human tears, as it could have a role in the interaction of the tear fluid with hyaluronan. Protein expression was evaluated by Western blots and immunofluorescence microscopy. mRNA expression was evaluated by RT-PCR and Q-PCR. sCD44 was analyzed by ELISA in culture supernatants and in human tears. We describe the expression of RHAMM in human healthy conjunctiva and in HCE and IOBA-NHC cells at both protein and mRNA levels, and the presence of sCD44 in human tears. Furthermore, we detected CD44 and sCD44 expression variations in in vitro inflammatory conditions. This study also focused on the necessary caution with which the conclusions extracted from cell lines should be made, and in the great value of using primary samples as often as possible.
Alteration of Galectin-3 in Tears of Patients with Dry Eye Disease
Uchino, Yuichi; Mauris, Jerome; Woodward, Ashley M.; Dieckow, Julia; Amparo, Francisco; Dana, Reza; Mantelli, Flavio; Argüeso, Pablo
2015-01-01
Purpose To investigate the expression, release, and proteolytic degradation of galectin-3 in patients with dry eye disease. Design Observational case series with a comparison group. Methods Tear washes and conjunctival impression cytology specimens were collected through standard procedures from 16 patients with dry eye and 11 age-matched healthy subjects. Galectin-3 content in tears was analyzed by quantitative Western blot, using recombinant galectin-3 protein to generate a calibration curve. The relative expression of galectin-3 and matrix metalloproteinase 9 (MMP9) was evaluated by quantitative polymerase chain reaction. The cleavage of galectin-3 was studied in vitro using activated recombinant MMP9 and protease inhibitors. Results The concentration of galectin-3 protein in tears, but not galectin-3 expression in conjunctival epithelium, was significantly higher in tears of patients with dry eye (0.38 ng/μg total protein, range 0.04-1.36) compared to healthy subjects (0.12 ng/μg total protein, range 0.00-0.41) (P < .01). By Western blot, an intact (∼28.0 kDa) galectin-3 band was identified in tear samples from healthy subjects, whereas 50% of the dry eye samples were characterized by the additional presence of a partially degraded form (∼25.4 kDa). In our experiments, elevated expression of MMP9 in dry eye subjects correlated with the ability of active MMP9 to cleave galectin-3 from recombinant origin. Interestingly, cleavage of endogenous galectin-3 in tear samples was impaired using a broad-spectrum proteinase inhibitor cocktail, but not the pan-specific MMP inhibitor GM6001, suggesting the presence of proteases other than MMPs in promoting galectin-3 degradation in dry eye. Conclusions Our results indicate that release of cellular galectin-3 into tears is associated with epithelial dysfunction in dry eye, and that galectin-3 proteolytic cleavage may contribute to impaired ocular surface barrier function. PMID:25703476
Alteration of galectin-3 in tears of patients with dry eye disease.
Uchino, Yuichi; Mauris, Jerome; Woodward, Ashley M; Dieckow, Julia; Amparo, Francisco; Dana, Reza; Mantelli, Flavio; Argüeso, Pablo
2015-06-01
To investigate the expression, release, and proteolytic degradation of galectin-3 in patients with dry eye disease. Observational case series with a comparison group. Tear washes and conjunctival impression cytology specimens were collected through standard procedures from 16 patients with dry eye and 11 age-matched healthy subjects. Galectin-3 content in tears was analyzed by quantitative Western blot, using recombinant galectin-3 protein to generate a calibration curve. The relative expression of galectin-3 and matrix metalloproteinase 9 (MMP9) was evaluated by quantitative polymerase chain reaction. The cleavage of galectin-3 was studied in vitro using activated recombinant MMP9 and protease inhibitors. The concentration of galectin-3 protein in tears, but not galectin-3 expression in conjunctival epithelium, was significantly higher in tears of patients with dry eye (0.38 ng/μg total protein, range 0.04-1.36) compared to healthy subjects (0.12 ng/μg total protein, range 0.00-0.41) (P < .01). By Western blot, an intact (∼28.0 kDa) galectin-3 band was identified in tear samples from healthy subjects, whereas 50% of the dry eye samples were characterized by the additional presence of a partially degraded form (∼25.4 kDa). In our experiments, elevated expression of MMP9 in dry eye subjects correlated with the ability of active MMP9 to cleave galectin-3 from recombinant origin. Interestingly, cleavage of endogenous galectin-3 in tear samples was impaired using a broad-spectrum proteinase inhibitor cocktail, but not the pan-specific MMP inhibitor GM6001, suggesting the presence of proteases other than MMPs in promoting galectin-3 degradation in dry eye. Our results indicate that release of cellular galectin-3 into tears is associated with epithelial dysfunction in dry eye, and that galectin-3 proteolytic cleavage may contribute to impaired ocular surface barrier function. Copyright © 2015 Elsevier Inc. All rights reserved.
Pflugfelder, Stephen C; De Paiva, Cintia S; Villarreal, Arturo L; Stern, Michael E
2008-01-01
To evaluate the effects of sequential treatment with artificial tears and cyclosporine emulsion on conjunctival goblet cell density and production of transforming growth factor (TGF)-beta2 in patients with dry eye disease. Patients with dry eye disease (N = 6) defined by an Ocular Surface Disease Index symptom score >or=25, Schirmer test 1 <10 mm, and corneal fluorescein and conjunctival lissamine green staining scores >or=3 were treated with artificial tears (Refresh Plus; Allergan, Irvine, CA) 4 times a day for 4 weeks, followed by 0.05% cyclosporine emulsion (Restasis; Allergan) twice a day for 12 weeks. Impression cytology was performed on the bulbar conjunctiva of both eyes at baseline, after artificial tear therapy, and after 6 and 12 weeks of cyclosporine therapy. Goblet cells were counted in 5 representative microscopic fields per membrane in those taken from the temporal and inferior bulbar conjunctiva of the worse eye, and membranes taken from the fellow eye were immunostained for TGF-beta2. There were no differences in mean goblet cell density between baseline and 4 weeks of artificial tears in the temporal and inferior bulbar specimens. After 6 weeks of cyclosporine emulsion, goblet cell density was significantly greater than baseline and artificial tears in the inferior bulbar conjunctiva (P < 0.01). After 12 weeks of cyclosporine emulsion, goblet cell density was significantly greater than baseline and artificial tears in both temporal and inferior bulbar sites (P < 0.01). The number of TGF-beta2-positive goblet cells was also noted to increase after 6 and 12 weeks of cyclosporine therapy (P < 0.001). Cyclosporine emulsion, but not artificial tears, increases goblet cell density and production of the immunoregulatory factor TGF-beta2 in the bulbar conjunctiva in patients with dry eye.
NASA Astrophysics Data System (ADS)
García-Resúa, C.; Giráldez, M. J.; Barreira, N.; Penedo, M. G.; Yebra-Pimentel, E.
2011-05-01
Purpose: The lipid layer of the tear film limits evaporation during the inter-blink interval and also affects tear stability. This study was designed to validate a new software application designed to characterize the tear film lipid layer through texture and colour pattern recognition. Methods: Using the Tearscope-plus (slit lamp magnification 200X), the lipid layer was examined in 105 healthy young adults and interference photographs acquired with a Topcon DV-3 digital camera. The photographs were classified by the new software and by 2 further observers (observer 1 and observer 2) with experience in examining the eye surface. Results: Strong correlation was detected between the categories determined by the new application, observer 1 and observer 2 (Cramer's V, from 0.81 to 0.87, p<0.001). Best agreement (96.2%) was noted between the new method and observers 1 and 2 for recognizing meshwork patterns, whereas observers 1 and 2 showed greatest correspondence when classifying colour fringe patterns. Conclusions: The new application can objectively categorize LLPs using the Tearscope-plus.
Non-linear tearing of 3D null point current sheets
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wyper, P. F., E-mail: peterw@maths.dundee.ac.uk; Pontin, D. I., E-mail: dpontin@maths.dundee.ac.uk
2014-08-15
The manner in which the rate of magnetic reconnection scales with the Lundquist number in realistic three-dimensional (3D) geometries is still an unsolved problem. It has been demonstrated that in 2D rapid non-linear tearing allows the reconnection rate to become almost independent of the Lundquist number (the “plasmoid instability”). Here, we present the first study of an analogous instability in a fully 3D geometry, defined by a magnetic null point. The 3D null current layer is found to be susceptible to an analogous instability but is marginally more stable than an equivalent 2D Sweet-Parker-like layer. Tearing of the sheet createsmore » a thin boundary layer around the separatrix surface, contained within a flux envelope with a hyperbolic structure that mimics a spine-fan topology. Efficient mixing of flux between the two topological domains occurs as the flux rope structures created during the tearing process evolve within this envelope. This leads to a substantial increase in the rate of reconnection between the two domains.« less
Dependency of Tearing Mode Stability on Current and Pressure Profiles in DIII-D Hybrid Discharges
NASA Astrophysics Data System (ADS)
Kim, K.; Park, J. M.; Murakami, M.; La Haye, R. J.; Na, Y.-S.; SNU/ORAU; ORNL; Atomics, General; SNU; DIII-D Team
2016-10-01
Understanding the physics of the onset and evolution of tearing modes (TMs) in tokamak plasmas is important for high- β steady-state operation. Based on DIII-D steady-state hybrid experiments with accurate equilibrium reconstruction and well-measured plasma profiles, the 2/1 tearing mode can be more stable with increasing local current and pressure gradient at rational surface and with lower pressure peaking and plasma inductance. The tearing stability index Δ', estimated by the Rutherford equation with experimental mode growth rate was validated against Δ' calculated by linear eigenvalue solver (PEST3); preliminary comprehensive MHD modeling by NIMROD reproduced the TM onset reasonably well. We present a novel integrated modeling for the purpose of predicting TM onset in experiment by combining a model equilibrium reconstruction using IPS/FASTRAN, linear stability Δ' calculation using PEST3, and fitting formula for critical Δ' from NIMROD. Work supported in part by the US DoE under DE-AC05-06OR23100, DE-AC05-00OR22725, and DEFC02-04ER54698.
Nonlinear calculation of the m=1 internal kink instability in current carrying stellarators
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wakatani, M.
1978-02-01
Nonlinear properties of the m=1 internal kink mode are shown in a low beta current carrying stellarator. The effects of the external helical magnetic fields are considered through a rotational transform and the magnetic surface is assumed to be circular. Magnetic surfaces inside the iota sub eta + iota sub sigma = 1 surface shift and deform non-circularly, while magnetic surfaces outside the iota sub eta + iota sub sigma = 1 are not disturbed, where iota sub eta is a rotational transform due to helical magnetic fields and iota sub sigma is due to a plasma current. Many highermore » harmonics are excited after the fundamental mode saturates. When the external helical magnetic fields are lowered, the m=1 tearing mode similar to that in a low beta Tokamak grows and magnetic islands appear near the iota sub eta + iota sub sigma = 1 surface. For adequate helical magnetic fields, the current carrying stellarator becomes stable against both the m=1 internal kink mode and the m=1 internal kink mode and the m=1 tearing mode, without lowering the rotational transform.« less
Preoperative and post-operative sleep quality evaluation in rotator cuff tear patients.
Serbest, Sancar; Tiftikçi, Uğur; Askın, Aydogan; Yaman, Ferda; Alpua, Murat
2017-07-01
The aim of this study was to examine the potential relationship between subjective sleep quality and degree of pain in patients with rotator cuff repair. Thirty-one patients who underwent rotator cuff repair prospectively completed the Pittsburgh Sleep Quality Index, the Western Ontario Rotator Cuff Index, and the Constant and Murley shoulder scores before surgery and at 6 months after surgery. Preoperative demographic, clinical, and radiologic parameters were also evaluated. The study analysed 31 patients with a median age of 61 years. There was a significant difference preoperatively versus post-operatively in terms of all PSQI global scores and subdivisions (p < 0.001). A statistically significant improvement was determined by the Western Ontario Rotator Cuff Scale and the Constant and Murley shoulder scores (p ˂ 0.001). Sleep disorders are commonly seen in patients with rotator cuff tear, and after repair, there is an increase in the quality of sleep with a parallel improvement in shoulder functions. However, no statistically significant correlation was determined between arthroscopic procedures and the size of the tear and sleep quality. It is suggested that rotator cuff tear repair improves the quality of sleep and the quality of life. IV.
Large scale integration of CVD-graphene based NEMS with narrow distribution of resonance parameters
NASA Astrophysics Data System (ADS)
Arjmandi-Tash, Hadi; Allain, Adrien; (Vitto Han, Zheng; Bouchiat, Vincent
2017-06-01
We present a novel method for the fabrication of the arrays of suspended micron-sized membranes, based on monolayer pulsed-CVD graphene. Such devices are the source of an efficient integration of graphene nano-electro-mechanical resonators, compatible with production at the wafer scale using standard photolithography and processing tools. As the graphene surface is continuously protected by the same polymer layer during the whole process, suspended graphene membranes are clean and free of imperfections such as deposits, wrinkles and tears. Batch fabrication of 100 μm-long multi-connected suspended ribbons is presented. At room temperature, mechanical resonance of electrostatically-actuated devices show narrow distribution of their characteristic parameters with high quality factor and low effective mass and resonance frequencies, as expected for low stress and adsorbate-free membranes. Upon cooling, a sharp increase of both resonant frequency and quality factor is observed, enabling to extract the thermal expansion coefficient of CVD graphene. Comparison with state-of-the-art graphene NEMS is presented.
Effect of chitosan-N-acetylcysteine conjugate in a mouse model of botulinum toxin B-induced dry eye.
Hongyok, Teeravee; Chae, Jemin J; Shin, Young Joo; Na, Daero; Li, Li; Chuck, Roy S
2009-04-01
To evaluate the effect of a thiolated polymer lubricant, chitosan-N-acetylcysteine conjugate (C-NAC), in a mouse model of dry eye. Eye drops containing 0.5% C-NAC, 0.3% C-NAC, a vehicle (control group), artificial tears, or fluorometholone were applied in a masked fashion in a mouse model of induced dry eye from 3 days to 4 weeks after botulinum toxin B injection. Corneal fluorescein staining was periodically recorded. Real-time reverse transcriptase-polymerase chain reaction and immunofluorescence staining were performed at the end of the study to evaluate inflammatory cytokine expressions. Mice treated with C-NAC, 0.5%, and fluorometholone showed a downward trend that was not statistically significant in corneal staining compared with the other groups. Chitosan-NAC formulations, fluorometholone, and artificial tears significantly decreased IL-1beta (interleukin 1beta), IL-10, IL-12alpha, and tumor necrosis factor alpha expression in ocular surface tissues. The botulinum toxin B-induced dry eye mouse model is potentially useful in evaluating new dry eye treatment. Evaluation of important molecular biomarkers suggests that C-NAC may impart some protective ocular surface properties. However, clinical data did not indicate statistically significant improvement of tear production and corneal staining in any of the groups tested. Topically applied C-NAC might protect the ocular surface in dry eye syndrome, as evidenced by decreased inflammatory cytokine expression.
A Clinical Study of Subtype-based Prevalence of Dry Eye.
Rege, Aditya; Kulkarni, Varsha; Puthran, Neelam; Khandgave, Tejaswini
2013-10-01
Dry Eye is a multifactorial disease of the tearfilm and the ocular surface which may be due to reduced tear production or excessive tear evaporation resulting in discomfort, visual disturbance, and tear film instability with a potential damage to the ocular surface. Various population-based studies have been done to find out the prevalence and the magnitude of the problem. Women Health Study reported prevalence of 7.8% after screening 36995 subjects above 49 years by interview. The prevalence reported by Blue Mountain Study was 15.3% .The Beaver Dam Study and Shiphai Eye studies are other studies reporting prevalence of 14.5% and 33.7% respectively. McMonnies questionnaire is a widely used screening instrument for Dry-Eye syndromes with sensitivity reportedly varying between 87% and 98% and specificity between 87% and 97%. Prevalence studies use McMonnie's questionnaire for screening individuals for Dry Eye, whereafter tests like Schirmer's test, Tear Film Break Up Time test, Rose Bengal test, Lissamine Green test and Meibomian Gland Dysfunction test are useful for further evaluation. While these tests help to differentiate the subtypes of Dry Eye such as Lipid Anomaly Dry Eye, Aqueous Tear Deficiency and Mucin Layer Deficiency, however, their sensitivity and specificity has not been widely studied. Additionally, very few studies have reported the prevalence of the various subtypes of Dry Eye. To determine the subtype-based prevalence of Dry Eye, to study the specificity and sensitivity of clinical tests for Dry Eye and to correlate McMonnies questionnaire with Dry Eye tests results. A prospective, cross-sectional, observational study, duly approved by the Institutional Ethics Committee, was conducted from October 2010 to April 2012. A total of 4750 subjects above 18 yrs of age were screened by the McMonnies questionnaire. Respondents having a score greater than 14.5 were subjected to clinical Dry Eye tests. The data obtained was analyzed using chi-square test. p value < 0.005 was considered statistically significant.The specificity and sensitivity of each clinical test was calculated using Schirmer's test as gold standard. The prevalence of Dry Eye was 15.4%, with a female preponderance (p = 0.01) and a significant increase with age above 60 years was noted (p<0.0001). Tear Film Break Up Time was the most reliable test with a good sensitivity (68.85%) and specificity (78.32%). Lipid Anomaly Dry Eye was the most prevalent (14.48%) followed by Aqueous Tear Deficiency (13.36%) and Mucin Layer Deficiency (3.51%). A positive correlation between McMonnies score and severity of Dry Eye was seen. This study suggests that Lipid Layer Anomaly is the most prevalent subtype in Dry Eye. Tear Film Break Up Time test is the most likely test to diagnose mild Dry Eye. McMonies Questionnaire can be effectively used for screening of a large population. Tear Film Break Up Time was found to have better sensitivity as well as specificity than other tests used for diagnosing Dry Eye.
Frangiamore, Salvatore J; Lynch, T Sean; Vaughn, Michael D; Soloff, Lonnie; Forney, Michael; Styron, Joseph F; Schickendantz, Mark S
2017-07-01
A medial ulnar collateral ligament (UCL) injury of the elbow is an increasingly common injury in professional baseball pitchers. Predictors of success and failure are not well defined for the nonoperative management of these injuries. To evaluate the efficacy of objective measures to predict failure of the nonoperative management of UCL injuries. Case-control study; Level of evidence, 3. Thirty-two professional pitchers (82%) met inclusion criteria and underwent an initial trial of nonoperative treatment for UCL tears based on clinical and radiological findings. Age, preseason physical examination results, magnetic resonance imaging (MRI) characteristics, and performance metrics were analyzed for these pitchers. Successful nonoperative management was defined as a return to the same level of play or higher for >1 year. Failure was defined as recurrent pain or weakness requiring a surgical intervention after a minimum of 3 months' rest when attempting a return to a throwing rehabilitation program. Thirty-two pitchers (mean age, 22.3 years) who underwent initial nonoperative treatment of UCL injuries were evaluated. Thirty-four percent (11/32) failed and required subsequent ligament reconstruction. Sixty-six percent (21/32) successfully returned to the same level of play for 1 year without a surgical intervention. There was no significant difference seen in physical examination findings or performance metrics between these patients. When comparing MRI findings between the groups, 82% (9/11) ( P < .001) who failed nonoperative management had distal tears, and 81% (17/21) who did not fail had proximal tears ( P < .001). When adjusting for age, location, and evidence of chronic changes on MRI, the likelihood of failing nonoperative management was 12.40 times greater ( P = .020) with a distal tear. No other variable alone or in combination reached significance. When combining the parameters of a high-grade tear and distal location, 88% (7/8) failed nonoperative management. In professional pitchers, distal UCL tears showed significantly higher odds of failure with nonoperative management compared with proximal tears. Thus, tear location should be considered when deciding between operative and nonoperative management.
ITER Baseline Scenario with ECCD Applied to Neoclassical Tearing Modes in DIII-D
NASA Astrophysics Data System (ADS)
Welander, A. G.; La Haye, R. J.; Lohr, J. M.; Humphreys, D. A.; Prater, R.; Paz-Soldan, C.; Kolemen, E.; Turco, F.; Olofsson, E.
2015-11-01
The neoclassical tearing mode (NTM) is a magnetic island that can occur on flux surfaces where the safety factor q is a rational number. Both m/n=3/2 and 2/1 NTM's degrade confinement, and the 2/1 mode often locks to the wall and disrupts the plasma. An NTM can be suppressed by depositing electron cyclotron current drive (ECCD) on the q-surface by injecting microwave beams into the plasma from gyrotrons. Recent DIII-D experiments have studied the application of ECCD/ECRH in the ITER Baseline Scenario. The power required from the gyrotrons can be significant enough to impact the fusion gain, Q in ITER. However, if gyrotron power could be minimized or turned off in ITER when not needed, this impact would be small. In fact, tearing-stable operation at low torque has been achieved previously in DIII-D without EC power. A vision for NTM control in ITER will be described together with results obtained from simulations and experiments in DIII-D under ITER like conditions. Work supported by the US DOE under DE-FC02-04ER54698, DE-AC02-09CH11466, DE-FG02-04ER54761.
NASA Astrophysics Data System (ADS)
Chen, W.; Jiang, M.; Xu, Y.; Shi, P. W.; Yu, L. M.; Ding, X. T.; Shi, Z. B.; Ji, X. Q.; Yu, D. L.; Li, Y. G.; Yang, Z. C.; Zhong, W. L.; Qiu, Z. Y.; Li, J. Q.; Dong, J. Q.; Yang, Q. W.; Liu, Yi.; Yan, L. W.; Xu, M.; Duan, X. R.
2017-11-01
Multi-scale interactions have been observed recently in the HL-2A core NBI plasmas, including the synchronous coupling between m/n=1/1 kink mode and m/n=2/1 tearing mode, nonlinear couplings of TAE/BAE and m/n=2/1 TM near q=2 surface, AITG/KBM/BAE and m/n=1/1 kink mode near q=1 surface, and between m/n=1/1 kink mode and high-frequency turbulence. Experimental results suggest that several couplings can exist simultaneously, Alfvenic fluctuations have an important contribution to the high-frequency turbulence spectra, and the couplings reveal the electromagnetic character. Multi-scale interactions via the nonlinear modulation process maybe enhance plasma transport and trigger sawtooth-crash onset.
Wang, Xiu; Lu, Xiaoxiao; Yang, Jun; Wei, Ruihua; Yang, Liyuan; Zhao, Shaozhen; Wang, Xilian
2016-01-01
Purpose. This study aims to evaluate dry eye and ocular surface conditions of myopic teenagers by using questionnaire and clinical examinations. Methods. A total of 496 eyes from 248 myopic teenagers (7–18 years old) were studied. We administered Ocular Surface Disease Index (OSDI) questionnaire, slit-lamp examination, and Keratograph 5M. The patients were divided into 2 groups based on OSDI dry eye standard, and their ocular surfaces and meibomian gland conditions were evaluated. Results. The tear meniscus heights of the dry eye and normal groups were in normal range. Corneal fluorescein scores were significantly higher whereas noninvasive break-up time was dramatically shorter in the dry eye group than in the normal group. All three meibomian gland dysfunction parameters (i.e., meibomian gland orifice scores, meibomian gland secretion scores, and meibomian gland dropout scores) of the dry eye group were significantly higher than those of the normal group (P < 0.0001). Conclusions. The prevalence of dry eye in myopic teenagers is 18.95%. Meibomian gland dysfunction plays an important role in dry eye in myopic teenagers. The Keratograph 5M appears to provide an effective noninvasive method for assessing ocular surface situation of myopic teenagers. PMID:26881059
Black, Perry
2002-03-01
Cerebrospinal fluid (CSF) leaks are relatively common following spinal surgery. A midline dural tear in the spine is readily repaired by direct application of sutures; however, far-lateral or ventral dural tears are problematic. Fat is an ideal sealant because it is impermeable to water. In this paper the author reports his experience with using fat grafts for the prevention or repair of CSF leaks and proposes a technique in which a large sheet of fat, harvested from the patient's subcutaneous layer, is used to cover not only the dural tear(s) but all of the exposed dura and is tucked into the lateral recess. This procedure prevents CSF from seeping around the fat, which may be tacked to the dura with a few sutures. Fibrin glue is spread on the surface of the fat and is further covered with Surgicel or Gelfoam. For ventral dural tears (associated with procedures in which disc material is excised), fat is packed into the disc space to seal off the ventral dural leak. Dural suture lines following spinal intradural exploration are prophylatically protected from CSF leakage in the same manner. With one exception, 27 dural tears noted during 1650 spinal procedures were successfully repaired using this technique. There was one case of postoperative CSF leakage in 140 cases in which intradural exploration for tumor or other lesions was undertaken. Both postoperative CSF leaks were controlled by applying additional skin sutures. The use of a fat graft is recommended as a rapid, effective means of prevention and repair of CSF leaks following spinal surgery.
Transverse conductivity of a relativistic plasma in oblique electric and magnetic fields
NASA Technical Reports Server (NTRS)
Melia, Fulvio; Fatuzzo, Marco
1991-01-01
Resistive tearing in a primary candidate for flares occurring in stressed magnetic fields. Its possible application to the strongly magnetized environments (Hz about 10 to the 12th G) near the surface of neutron stars, particularly as a mechanism for generating the plasma heating and particle acceleration leading to gamma-ray bursts, has motivated a quantum treatment of this process, which requires knowledge of the electrical conductivity sigma of a relativistic gas in a new domain (i.e., that of a low-density n/e/) plasma in oblique electric and magnetic fields. This paper discusses the mathematical formalism for calculating sigma and present numerical results for a wide range of parameter values. The results indicate that sigma depends very strongly on both the applied electric and magnetic fields.
Self-Organisation and Intermittent Coherent Oscillations in the EXTRAP T2 Reversed Field Pinch
NASA Astrophysics Data System (ADS)
Cecconello, M.; Malmberg, J.-A.; Sallander, E.; Drake, J. R.
Many reversed-field pinch (RFP) experiments exhibit a coherent oscillatory behaviour that is characteristic of discrete dynamo events and is associated with intermittent current profile self-organisation phenomena. However, in the vast majority of the discharges in the resistive shell RFP experiment EXTRAP T2, the dynamo activity does not show global, coherent oscillatory behaviour. The internally resonant tearing modes are phase-aligned and wall-locked resulting in a large localised magnetic perturbation. Equilibrium and plasma parameters have a level of high frequency fluctuations but the average values are quasi-steady. For some discharges, however, the equilibrium parameters exhibit the oscillatory behaviour characteristic of the discrete dynamo events. For these discharges, the trend observed in the tearing mode spectra, associated with the onset of the discrete relaxation event behaviour, is a relative higher amplitude of m = 0 mode activity and relative lower amplitude of the m = 1 mode activity compared with their average values. Global plasma parameters and model profile calculations for sample discharges representing the two types of relaxation dynamics are presented.
Axial crack propagation and arrest in pressurized fuselage
NASA Technical Reports Server (NTRS)
Kosai, M.; Shimamoto, A.; Yu, C.-T.; Walker, S. I.; Kobayashi, A. S.; Tan, P.
1994-01-01
The crack arrest capability of a tear strap in a pressurized precracked fuselage was studied through instrumented axial rupture tests of small scale models of an idealized fuselage. Upon pressurization, rapid crack propagation initiated at an axial through crack along the stringer and immediately kinked due to the mixed modes 1 and 2 state caused by the one-sided opening of the crack flap. The diagonally running crack further turned at the tear straps. Dynamic finite element analysis of the rupturing cylinder showed that the crack kinked and also ran straight in the presence of a mixed mode state according to a modified two-parameter crack kinking criterion.
Extreme Facial Expressions Classification Based on Reality Parameters
NASA Astrophysics Data System (ADS)
Rahim, Mohd Shafry Mohd; Rad, Abdolvahab Ehsani; Rehman, Amjad; Altameem, Ayman
2014-09-01
Extreme expressions are really type of emotional expressions that are basically stimulated through the strong emotion. An example of those extreme expression is satisfied through tears. So to be able to provide these types of features; additional elements like fluid mechanism (particle system) plus some of physics techniques like (SPH) are introduced. The fusion of facile animation with SPH exhibits promising results. Accordingly, proposed fluid technique using facial animation is the real tenor for this research to get the complex expression, like laugh, smile, cry (tears emergence) or the sadness until cry strongly, as an extreme expression classification that's happens on the human face in some cases.
Rolle, Teresa; Spinetta, Roberta; Nuzzi, Raffaele
2017-08-03
The effects of preservatives of antiglaucoma medications on corneal surface and tear function have been widely shown in literature; it's not the same as regards the active compounds themselves. The purpose of our study was to compare Ocular Surface Disease (OSD) signs and symptoms of Tafluprost 0.0015% versus preservative free (PF) Timolol 0.1% eyedrops in ocular hypertensive (OH) and in primary open-angle glaucoma (POAG) patients. A cross-sectional study included patients in monotherapy for at least 36 months with Tafluprost 0.0015% (27) or PF Timolol 0.1% (24) and 20 healthy age and sex-matched volunteers. All subjects underwent clinical tests (Schirmer I and break-up time), in vivo confocal microscopy (IVCM) and were surveyed using Ocular Surface Disease Index (OSDI) and Glaucoma Symptoms Scale (GSS) questionnaires. The groups were compared with ANOVA, Kruskal-Wallis test, t-test, Mann-Whitney test and Bonferroni's adjustment of p-values. No significant differences were found in questionnaires scores, clinical tests, IVCM variables between therapy groups. Tafluprost 0.0015% group showed significantly higher OSDI score, basal epithelial cells density, stromal reflectivity, sub-basal nerves tortuosity (p = 0.0000, 0.037, 0.006, 0.0000) and less GSS score, number of sub-basal nerves (p = 0.0000, 0.037) than controls but similar clinical tests results (p > 0.05). PF Timolol group had significantly higher OSDI score, basal epithelial cells density, stromal reflectivity and sub-basal nerve tortuosity (p = 0.000, 0.014, 0.008, 0.002), less GSS score, BUT and number of sub-basal nerves (p = 0.0000, 0.026, 0.003) than controls. Compared to PF Timolol 0.1%, Tafluprost 0.0015% showed similar safety with regards to tear function and corneal status and a similar tolerability profile. Both therapy groups show some alterations in corneal microstructure but no side effects on tear function except for an increased tear instability in PF Timolol 0.1% group. Ophtalmologists should be aware that even PF formulations may lead to a mild ocular surface impairment.
Effects of topical acne treatment on the ocular surface in patients with acne vulgaris.
Aslan Bayhan, Seray; Bayhan, Hasan Ali; Çölgeçen, Emine; Gürdal, Canan
2016-12-01
To assess the ocular side effects during topical retinoid-antibiotic combination treatment in patients with facial acne vulgaris. Forty-three patients applying topical isotretinoin+erythromycin combination (isotrexin gel, GlaxoSmithKline) once daily for the treatment of acne vulgaris were enrolled. Full ophthalmologic examination, Schirmer test (with topical anesthesia), fluorescein break-up time (BUT), corneal fluorescein staining and tear osmolarity measurement with the TearLab system (TearLab Corporation) were carried out before and at the end of the first month of the treatment. For evaluation of symptoms participants completed the ocular surface disease index (OSDI) questionnaire at each visit. The mean age of the patients was 23.16±3.03 (18-30) years. Mean tear osmolarity increased significantly from 282.09±8.95 mOsm/L at baseline to 300.39±16.65 mOsm/L after the treatment (p<0.001). BUT decreased from an average of 11.93±1.12s at baseline to 6.65±3.03s at the end of the first month (p<0.001). The OSDI score worsened significantly (5.41±3.65 vs 21.53±12.95, p<0.001) and punctate epitheliopathy was seen in 51% of eyes after the treatment. The average Schirmer values were 13.09±1.90 and 12.41±2.44mm/5min before and at the end of the first month of the treatment, respectively (p=0.117). The findings of this study indicate that topical retinoid-antibiotic combination treatment causes significant signs and symptoms of dry eye. Patients receiving topical treatment for acne should be evaluated regularly to ensure the timely detection and treatment of pathologic signs on the ocular surface. Copyright © 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Effect of mistletoe combined with carboxymethyl cellulose on dry eye in postmenopausal women
Jiang, Nan; Ye, Lin-Hong; Ye, Lei; Yu, Jing; Yang, Qi-Chen; Yuan, Qing; Zhu, Pei-Wen; Shao, Yi
2017-01-01
AIM To investigate the protective effect of mistletoe combined with carboxymethyl cellulose eye drops on dry eye in postmenopausal women. METHODS Sixty postmenopause female patients diagnosed of dry eye were assigned randomly to mistletoe combined with carboxymethyl cellulose eye drops treatment group (n=30) and control group treated with normal saline eye drops (n=30). The subjective symptoms of ocular surface, Ocular Surface Disease Index (OSDI), tear film function tests, tear protein and corneal morphology by confocal scanning microscopy were analyzed before treatment and at 1, 2, 4 and 8wk after treatment respectively. To ensure the safety of the trial, all patients were examined with systolic pressure, diastolic pressure, glutamic-pyruvic transaminase, glutamic oxaloacetic transaminase, urine creatinine, and blood urea nitrogen at 8wk after treatment. RESULTS There were no obvious differences between two groups before the treatment (P>0.05). In two months after the treatment, the symptoms of ocular surface, OSDI, tear protein, and tear film function were only slightly changed in normal saline eye drops group. However, all indices were improved after the treatment of mistletoe combined with carboxymethyl cellulose eye drops group (P<0.05). In addition, the average amount of corneal epithelium basal cells and inflammatory cells of mistletoe treated group were 3174±379 and 38±25 cells/mm2, significantly decreased as compared to the control group with 4309±612 and 158± 61 cells/mm2, respectively. In the control group, although nerves still maintained straight under corneal epithelium, the number of nerves were significantly decreased, as compared with normal female. In the mistletoe treated group, the number of nerves was only slightly reduced, compared with normal female. CONCLUSION Mistletoe combined with carboxymethyl cellulose eye drops can alleviate the symptoms and signs of dry eye symptoms. PMID:29181309
Racial variations in interfacial behavior of lipids extracted from worn soft contact lenses.
Svitova, Tatyana F; Lin, Meng C
2013-12-01
To explore interfacial behaviors and effects of temperature and dilatation on dynamic properties of multilayered human tear lipids extracted from silicone hydrogel (SiH) lenses worn by asymptomatic Asian and white subjects. Interfacial properties of lipids extracted from Focus N&D lenses worn by 14 subjects continuously for 1 month were studied. The lipids were deposited on an air bubble immersed in a model tear electrolyte (MTE) solution to form 100 ± 20-nm-thick films. Surface pressure was recorded during slow expansion/contraction cycles to evaluate compressibility and hysteresis of lipid films. Films were also subjected to fast step-strain dilatations at temperatures of 22 to 45°C for their viscoelastic property assessment. Isocycles for Asian and white lipids were similar at low surface pressures but had distinctly different compressibility and hysteresis at dynamic pressures exceeding 30 mN/m. Rheological parameters of reconstituted lipids were also dissimilar between Asian and white. The elastic modulus E∞ for white lipids was 1.5 times higher than that for Asian lipids, whereas relaxation time (t) was on average 1.3 times higher for Asian. No significant changes were observed in rheological properties of both Asian and white lipids when temperature increased from 22.0 to 36.5°C. However, for white lipids, E∞ reduced considerably at temperatures higher than 42.0°C, whereas t remained unchanged. For Asian lipids, both E∞ and t started to decline as temperature increased to 38°C and higher. Higher elastic modulus of white lipids and elasticity threshold at certain deformations indicate stronger structure and intermolecular interactions as compared with more viscous Asian lipids. The differences in interfacial behaviors between Asian and white lipids may be associated with the differences in their chemical compositions.
Glycan involvement in the adhesion of Pseudomonas aeruginosa to tears.
Kautto, Liisa; Nguyen-Khuong, Terry; Everest-Dass, Arun; Leong, Andrea; Zhao, Zhenjun; Willcox, Mark D P; Packer, Nicolle H; Peterson, Robyn
2016-04-01
The human eye is constantly bathed by tears, which protect the ocular surface via a variety of mechanisms. The O-linked glycans of tear mucins have long been considered to play a role in binding to pathogens and facilitating their removal in the tear flow. Other conjugated glycans in tears could similarly contribute to pathogen binding and removal but have received less attention. In the work presented here we assessed the contribution of glycan moieties, in particular the protein attached N-glycans, presented by the broad complement of tear proteins to the adhesion of the opportunistic pathogen Pseudomonas aeruginosa, a leading cause of microbial keratitis and ulceration of the cornea. Our adhesion assay involved immobilising the macromolecular components of tears into the wells of a polyvinyl difluoride (PVDF) microtitre filter plate and probing the binding of fluorescently labelled bacteria. Three P. aeruginosa strains were studied: a cytotoxic strain (6206) and an invasive strain (6294) from eye infections, and an invasive strain (320) from a urinary tract infection (UTI). The ocular isolates adhered two to three times more to human tears than to human saliva or porcine gastric mucin, suggesting ocular niche-specific adaptation. Support for the role of the N-glycans carried by human tear proteins in the binding and removal of P. aeruginosa from the eye was shown by: 1) pre-incubation of the bacteria with free component sugars, galactose, mannose, fucose and sialyl lactose (or combination thereof) inhibiting adhesion of all the P. aeruginosa strains to the immobilised tear proteins, with the greatest inhibition of binding of the ocular cytotoxic 6206 and least for the invasive 6294 strain; 2) pre-incubation of the bacteria with N-glycans released from the commercially available human milk lactoferrin, an abundant protein that carries N-linked glycans in tears, inhibiting the adhesion to tears of the ocular bacteria by up to 70%, which was significantly more binding inhibition than by the same amount of intact human lactoferrin or by the plant-derived N-glycans released from the rice recombinant lactoferrin; 3) pre-incubation of the bacteria with N-linked glycans released from human tear proteins inhibiting the adhesion of the ocular P. aeruginosa strains to immobilised tear proteins; 4) inhibition by the N-glycans from lactoferrin of the ability of an ocular strain of P. aeruginosa to invade corneal epithelial cells; 5) removal of terminal sialic acid and fucose moieties from the tear glycoproteins with α2-3,6,8 neuraminidase (sialidase) and α1-2,3,4 fucosidase resulting in a reduction in binding of the UTI P. aeruginosa isolate, but not the adhesion of the ocular cytotoxic (6206) or invasive (6294) isolates. Glycosidase activity was validated by mass spectrometry. In all cases, the magnitude of inhibition of bacterial adhesion by the N-glycans was consistently greater for the cytotoxic ocular strain than for the invasive ocular strain. Ocular P. aeruginosa isolates seems to exhibit different adhesion mechanism than previously known PAI and PAII lectin adhesion. The work may contribute towards the development of glycan-focused therapies to prevent P. aeruginosa infection of the eye. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Xu, J. Q.; Peng, X. D.
2018-04-01
The effect of plasma rotation on the linear stability of the resistive magnetohydrodynamic (MHD) instabilities with a nonmonotonic q profile is investigated numerically in the cylindrical geometry. The results have shown that the plasma rotation has a stabilization effect on the double tearing modes (DTMs) depending on the magnitude of the velocity, while the velocity shear has a relatively weak effect. The effect of rotation on DTMs is determined by the velocity at each rational surface. A toroidal velocity imposed on the innermost rational surface has a weak effect on m > 1 DTMs. When the velocity is imposed on the outboard resonant surface, the growth rates of the DTMs are reduced for m > 1 modes; however, it has an obvious destabilizing effect on both m = 1 (with m the poloidal mode number) DTM and single tearing mode branches if the distance between the two rational surfaces is sufficiently small. It is shown that the effect of plasma rotation on the growth rates of the MHD instabilities is in phase with the integrated value of the coupling between potential fluctuation and magnetic flux perturbation.
Lee, Jee Bum; Li, Ying; Choi, Ji Suk; Lee, Hyo Seok
2016-01-01
Purpose. To investigate the therapeutic effects of topical administration of antioxidant medicinal plant extracts in a mouse model of experimental dry eye (EDE). Methods. Eye drops containing balanced salt solution (BSS) or 0.001%, 0.01%, and 0.1% extracts were applied for the treatment of EDE. Tear volume, tear film break-up time (BUT), and corneal fluorescein staining scores were measured 10 days after desiccating stress. In addition, we evaluated the levels of interleukin- (IL-) 1β, tumor necrosis factor- (TNF-) α, IL-6, interferon- (IFN-) γ, and IFN-γ associated chemokines, percentage of CD4+C-X-C chemokine receptor type 3 positive (CXCR3+) T cells, goblet cell density, number of 4-hydroxy-2-nonenal (4-HNE) positive cells, and extracellular reactive oxygen species (ROS) production. Results. Compared to the EDE and BSS control groups, the mice treated with topical application of the 0.1% extract showed significant improvements in all clinical parameters, IL-1β, IL-6, TNF-α, and IFN-γ levels, percentage of CD4+CXCR3+ T cells, goblet cell density, number of 4-HNE-positive cells, and extracellular ROS production (P < 0.05). Conclusions. Topical application of 0.1% medicinal plant extracts improved clinical signs, decreased inflammation, and ameliorated oxidative stress marker and ROS production on the ocular surface of the EDE model mice. PMID:27313829
NASA Technical Reports Server (NTRS)
Lee, L. C.; Wang, S.; Wei, C. Q.; Tsurutani, B. T.
1988-01-01
This paper investigates the growth rates and eigenmode structures of the streaming sausage, kink, and tearing instabilities in a current sheet with a super-Alfvenic flow. The growth rates and eigenmode structures are first considered in the ideal incompressible limit by using a four-layer model, as well as a more realistic case in which all plasma parameters and the magnetic field vary continuously along the direction perpendicular to the magnetic field and plasma flow. An initial-value method is applied to obtain the growth rate and eigenmode profiles of the fastest growing mode, which is either the sausage mode or kink mode. It is shown that, in the earth's magnetotail, where super-Alfvenic plasma flows are observed in the plasma sheet and the ratio between the plasma and magnetic pressures far away from the current layer is about 0.1-0.3 in the lobes, the streaming sausage and streaming tearing instabilities, but not kink modes, are likely to occur.
Wu, Yu-Chieh; Buckner, Benjamin R; Zhu, Meifang; Cavanagh, H Dwight; Robertson, Danielle M
2012-04-01
To determine the ratio of IGFBP3:IGF-1 in normal and diabetic human tears, and in telomerase-immortalized human corneal epithelial cells (hTCEpi) cultured under elevated glucose conditions and to correlate these changes with total and phosphorylated levels of IGF-1R. Tear samples were collected noninvasively from diabetic subjects and non-diabetic controls; corneal sensitivity was assessed using a Cochet-Bonnet Aesthesiometer. Conditioned media were collected following culture of hTCEpi cells in normal (5 mM) and elevated (25 mM) glucose conditions; mannitol was used as an osmotic control. IGFBP3, IGF-1, and phosphorylated IGF-1R levels were assessed by ELISA. IGFBP3 and IGF-1R mRNA were assessed by real-time polymerase chain reaction (PCR). Total and phosphorylated IGF-1R expression in whole cell lysates was assessed by western blot. There was a 2.8-fold increase in IGFBP3 in diabetic tears compared to non-diabetic controls (P=0.006); IGF-1 levels were not significantly altered. No difference in corneal sensitivity was detected between groups. The concentration of IGFBP3 in tears was independent of IGF-1. Consistent with human tear measurements in vivo, IGFBP3 secretion was increased 2.2 fold (P<0.001) following culture of hTCEpi cells under elevated glucose conditions in vitro. Treatment with glucose and the mannitol control reduced IGFBP3 mRNA (P<0.001). Total IGF-1R levels were unchanged. The increase in the IGFBP3:IGF-1 ratio detected in diabetic tears compared to normal controls blocked phosphorylation of the IGF-1R by IGF-1 (P<0.001) when tested in vitro. Taken together, these in vivo and confirmatory in vitro findings suggest that the observed increase in IGFBP3 found in human tears may attenuate IGF-1R signaling in the diabetic cornea. A long-term increase in IGFBP3 may contribute to epithelial compromise and the pathogenesis of ocular surface complications reported in diabetes. Copyright © 2012 Elsevier Inc. All rights reserved.
Wu, Yu-Chieh; Buckner, Benjamin R.; Zhu, Meifang; Cavanagh, H. Dwight; Robertson, Danielle M.
2012-01-01
Purpose To determine the ratio of IGFBP3:IGF-1 in normal and diabetic human tears, and in telomerase-immortalized human corneal epithelial cells (hTCEpi) cultured under elevated glucose conditions and to correlate these changes with total and phosphorylated levels of IGF-1R. Methods Tear samples were collected noninvasively from diabetic subjects and non-diabetic controls; corneal sensitivity was assessed using a Cochet-Bonnet Aesthesiometer. Conditioned media were collected following culture of hTCEpi cells in normal (5 mM) and elevated (25 mM) glucose conditions; mannitol was used as an osmotic control. IGFBP3, IGF-1, and phosphorylated IGF-1R levels were assessed by ELISA. IGFBP3 and IGF-1R mRNA were assessed by real time polymerase chain reaction (PCR). Total and phosphorylated IGF-1R expression in whole cell lysates was assessed by western blot. Results There was a 2.8-fold increase in IGFBP3 in diabetic tears compared to non-diabetic controls (P=0.006); IGF-1 levels were not significantly altered. No difference in corneal sensitivity was detected between groups. The concentration of IGFBP3 in tears was independent of IGF-1. Consistent with human tear measurements in vivo, IGFBP3 secretion was increased 2.2 fold (P<0.001) following culture of hTCEpi cells under elevated glucose conditions in vitro. Treatment with glucose and the mannitol control reduced IGFBP3 mRNA (P<0.001). Total IGF-1R levels were unchanged. The increase in the IGFBP3:IGF-1 ratio detected in diabetic tears compared to normal controls blocked phosphorylation of the IGF-1R by IGF-1 (P<0.001) when tested in vitro. Conclusions Taken together, these in vivo and confirmatory in vitro findings suggest that the observed increase in IGFBP3 found in human tears may attenuate IGF-1R signaling in the diabetic cornea. A long-term increase in IGFBP3 may contribute to epithelial compromise and the pathogenesis of ocular surface complications reported in diabetes. PMID:22482470
Lee, Hoseok; Ahn, Joong Mo; Kang, Yusuhn; Oh, Joo Han; Lee, Eugene; Lee, Joon Woo; Kang, Heung Sik
2018-01-01
To compare the T1-weighted spectral presaturation with inversion-recovery sequences (T1 SPIR) with T2-weighted turbo spin-echo sequences (T2 TSE) on 3T magnetic resonance arthrography (MRA) in the evaluation of the subscapularis (SSC) tendon tear with arthroscopic findings as the reference standard. This retrospective study included 120 consecutive patients who had undergone MRA within 3 months between April and December 2015. Two musculoskeletal radiologists blinded to the arthroscopic results evaluated T1 SPIR and T2 TSE images in separate sessions for the integrity of the SSC tendon, examining normal/articular-surface partial-thickness tear (PTTa)/full-thickness tear (FTT). Diagnostic performance of T1 SPIR and T2 TSE was calculated with arthroscopic results as the reference standard, and sensitivity, specificity, and accuracy were compared using the McNemar test. Interobserver agreement was measured with kappa (κ) statistics. There were 74 SSC tendon tears (36 PTTa and 38 FTT) confirmed by arthroscopy. Significant differences were found in the sensitivity and accuracy between T1 SPIR and T2 TSE using the McNemar test, with respective rates of 95.9-94.6% vs. 71.6-75.7% and 90.8-91.7% vs. 79.2-83.3% for detecting tear; 55.3% vs. 31.6-34.2% and 85.8% vs. 78.3-79.2%, respectively, for FTT; and 91.7-97.2% vs. 58.3-61.1% and 89% vs. 78-79.3%, respectively, for PTTa. Interobserver agreement for T1 SPIR was almost perfect for T1 SPIR (κ = 0.839) and substantial for T2 TSE (κ = 0.769). T1-weighted spectral presaturation with inversion-recovery sequences is more sensitive and accurate compared to T2 TSE in detecting SSC tendon tear on 3T MRA.
Topical administration of lacritin is a novel therapy for aqueous-deficient dry eye disease.
Vijmasi, Trinka; Chen, Feeling Y T; Balasubbu, Suganthalakshmi; Gallup, Marianne; McKown, Robert L; Laurie, Gordon W; McNamara, Nancy A
2014-07-17
Lacritin is a tear glycoprotein with prosecretory, prosurvival, and mitogenic properties. We examined lacritin levels in the tears of Sjögren's syndrome (SS) patients and explored the therapeutic potential of topical lacritin for the treatment of keratoconjunctivitis sicca. Tears from healthy controls (n = 14) and SS patients (n = 15) were assayed for lacritin using a C-terminal antibody. In a paired-eye study, autoimmune regulator (Aire) knockout (KO) mice (n = 7) were treated three times daily for 21 days with 10 μL of 4 μM lacritin (left eye) or vehicle (PBS) control (right eye). Tear secretion and ocular surface integrity were assessed at baseline and after treatment. Immunohistochemical staining of CD4+ T cells, cytokeratin-10 (K10), and cytokeratin-12 (K12) expression in the cornea and CD4+ T cell infiltration in the lacrimal glands were assessed. Lacritin monomer (421.8 ± 65.3 ng [SS] vs. 655.8 ± 118.9 ng [controls]; P = 0.05) and C-terminal fragment protein (125 ± 34.1 ng [SS] vs. 399.5 ± 84.3 ng [controls]; P = 0.008) per 100 μL of tear eluate were significantly lower in SS patients. In Aire KO mice treated with lacritin, tear secretion increased by 46% (13.0 ± 3.5 mm vs. 8.9 ± 2.9 mm; P = 0.01) and lissamine green staining score significantly decreased relative to baseline (-0.417 ± 0.06 vs. 0.125 ± 0.07; P = 0.02). Expression of K10 but not K12 in the cornea was significantly decreased in lacritin-treated eyes. Focal CD4+ T cell infiltration of the lacrimal glands was significantly reduced on the lacritin-treated side versus the untreated side. Lacritin is significantly reduced in the tears of SS patients. Topically administered lacritin has therapeutic potential for the treatment of aqueous-deficient dry eye disease. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
Jee, Donghyun; Park, Minji; Lee, Hee Jin; Kim, Man Soo; Kim, Eun Chul
2015-04-01
To compare treatment with preservative-free and preserved sodium hyaluronate 0.1% and fluorometholone 0.1% eyedrops after cataract surgery in patients with preexisting dry-eye syndrome. Bucheon St. Mary's Hospital, Catholic University of Korea, Seoul, Korea. Randomized controlled study. Patients with cataract and dry-eye syndrome were randomly divided into 2 groups. Group 1 patients were treated with preservative-free sodium hyaluronate 0.1% and preservative-free fluorometholone 0.1% eyedrops 4 times a day in the first month and twice a day in the second month. Group 2 patients were treated with preserved eyedrops using the same schedule. Ocular Surface Disease Index (OSDI) score, tear-film breakup time (TBUT), Schirmer I test, corneal fluorescein staining, impression cytology, and antioxidant and inflammatory cytokine activities in tears were evaluated. Both groups comprised 40 patients. At 2 months, the OSDI score, TBUT, Schirmer I score, fluorescein staining score, impression cytology findings, and goblet cell count were significantly better in Group 1 than in Group 2 (P<.05). The interleukin-1β and tumor necrosis factor-α concentrations were significantly less in the tears of Group 1 patients than in the tears of Group 2 patients, and catalase and superoxide dismutase 2 fluorescence intensities were significantly greater in the tears of Group 1 patients than in the tears of Group 2 patients (P<.05). Preservative-free sodium hyaluronate 0.1% and fluorometholone 0.1% eyedrops can improve the symptoms and signs of dry-eye syndrome after cataract surgery. Preservative-free fluorometholone eyedrops may have antiinflammatory and antioxidant effects in tears of patients with dry-eye syndrome. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Functional lacrimal gland regeneration by transplantation of a bioengineered organ germ
Hirayama, Masatoshi; Ogawa, Miho; Oshima, Masamitsu; Sekine, Yurie; Ishida, Kentaro; Yamashita, Kentaro; Ikeda, Kazutaka; Shimmura, Shigeto; Kawakita, Tetsuya; Tsubota, Kazuo; Tsuji, Takashi
2013-01-01
The lacrimal gland has a multifaceted role in maintaining a homeostatic microenvironment for a healthy ocular surface via tear secretion. Dry-eye disease, which is caused by lacrimal gland dysfunction, is one of the most prevalent eye diseases that cause corneal epithelial damage and results in significant loss of vision and a reduction in the quality of life. Here we demonstrate orthotopic transplantation of bioengineered lacrimal gland germs into adult mice with an extra-orbital lacrimal gland defect, a mouse model that mimics the corneal epithelial damage caused by lacrimal gland dysfunction. The bioengineered lacrimal gland germs and harderian gland germs both develop in vivo and achieve sufficient physiological functionality, including tear production in response to nervous stimulation and ocular surface protection. This study demonstrates the potential for bioengineered organ replacement to functionally restore the lacrimal gland. PMID:24084941
Santamaría, Beatriz; Laguna, María F.; López-Romero, David; Hernandez, Ana L.; Sanza, Francisco J.; Lavín, Álvaro; Casquel, Rafael; Maigler, María V.; Espinosa, Rocío L.; Holgado, Miguel
2017-01-01
A novel compact optical biochip based on a thin layer-sensing surface of nitrocellulose is used for in-situ label-free detection of metalloproteinase (MMP9) related to dry eye disease. In this article, a new integrated chip with different interferometric transducers layout with an optimal sensing surface is reported for the first time. We demonstrate that specific antibodies can be immobilized onto these transducers with a very low volume of sample and with good orientation. Many sensing transducers constitute the presented biochip in order to yield statistical data and stability in the acquired measurements. As a result, we report the recognition curve for pure recombinant MMP9, tests of model tears with MMP9, and real tear performance from patients, with a promising limit of detection. PMID:28534808
Kaercher, Thomas; Dietz, Jasna; Jacobi, Christina; Berz, Reinhold; Schneider, Holm
2015-09-01
X-linked hypohidrotic ectodermal dysplasia (XLHED) is the most common form of ectodermal dysplasia. Clinical characteristics include meibomian gland disorder and the resulting hyperevaporative dry eye. In this study, we evaluated meibography and ocular infrared thermography as novel methods to diagnose XLHED. Eight infants, 12 boys and 14 male adults with XLHED and 12 healthy control subjects were subjected to a panel of tests including the ocular surface disease index (OSDI), meibography and infrared thermography, non-invasive measurement of tear film break-up time (NIBUT) and osmolarity, Schirmer's test, lissamine green staining and fluorescein staining. Sensitivity and specificity were determined for single tests and selected test combinations. Meibography had 100% sensitivity and specificity for identifying XLHED. Infrared thermography, a completely non-invasive procedure, revealed a typical pattern for male subjects with XLHED. It was, however, less sensitive (86% for adults and 67% for children) than meibography or a combination of established routine tests. In adults, OSDI and NIBUT were the best single routine tests (sensitivity of 86% and 71%, respectively), whereas increased tear osmolarity appeared as a rather unspecific ophthalmic symptom. In children, NIBUT was the most convincing routine test (sensitivity of 91%). Meibography is the most reliable ophthalmic examination to establish a clinical diagnosis in individuals with suspected hypohidrotic ectodermal dysplasia, even before genetic test results are available. Tear film tests and ocular surface staining are less sensitive in children, but very helpful for estimating the severity of ocular surface disease in individuals with known XLHED.
Tiwari, Mukesh; Singh, Varun; Bhargava, Rakesh
2015-01-01
Peroneus brevis tendinitis with its attritional longitudinal split rupture without any subluxation from peroneal groove and associated enlarged peroneal tubercle is un common presentation. A 40 year old female presented with moderate swelling and tenderness over the lateral and dorso-lateral aspect of left ankle with history of old trauma to ankle with swelling, persistant pain and difficulty in walking. On physical examination during passive eversion and inversion the excursion of the peroneal tendons was painful. Most tender point was just posterior to the tip of the fibula. During surgery we found the intact superior peroneal ligament with both peroneal tendons placed at normal site without subluxation, tendon sheath was inflamed and swollen, on further dissection we could see the attrition of inner surface of the peroneus brevis and a 2 cm longitudinal split tear of the same. Although rare but peroneus brevis tendon attrition and tear can occur without subluxation from peronal groove. Refractory ankle pain on lateral aspect presenting with on and off swelling should arise suspicion of peroneal tendon tear. Correct diagnosis and proper surgical repair can produce excellent results.
Takahashi, Kenji; Hashimoto, Sanshiro; Nakamura, Hiroshi; Mori, Atsushi; Sato, Akiko; Majima, Tokifumi; Takai, Shinro
2015-06-01
This study aimed to identify factors on routine pulse sequence MRI associated with cartilage degeneration observed on T1ρ relaxation mapping. This study included 137 subjects with knee pain. T1ρ values were measured in the regions of interest on the surface layer of the cartilage on mid-coronal images of the femorotibial joint. Assessment of cartilage, subchondral bone, meniscus and ligaments was performed using routine pulse sequence MRI. Radiographic evaluation for osteoarthritis was also performed. Multiple regression analysis revealed posterior root/horn tears to be independent factors increasing the T1ρ values of the cartilage in the medial compartment of the femorotibial joint. Even when adjusted for radiographically defined early-stage osteoarthritis, medial posterior meniscal radial tears significantly increased the T1ρ values. This study showed that posterior root/horn radial tears in the medial meniscus are particularly important MRI findings associated with cartilage degeneration observed on T1ρ relaxation mapping. Morphological factors of the medial meniscus on MRI provide findings useful for screening early-stage osteoarthritis. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Messmer, Elisabeth M; von Lindenfels, Victoria; Garbe, Alexandra; Kampik, Anselm
2016-11-01
To measure matrix metalloproteinase 9 (MMP-9) in the tear film of patients with dry eye disease (DED) compared with controls and to correlate clinical findings. In a prospective study, 101 patients and controls underwent MMP-9 testing of the tear film. Thereafter, they were evaluated for symptoms and signs of DED. Included patients were those who showed 3 of the following 4 dry eye criteria: ocular surface disease index (OSDI) score of more than 12, tear film break-up time (TBUT) of 10 seconds or less, Schirmer test results without anesthesia of less than 10 mm/5 minutes, and corneal staining results of 1 or more. Fifty-four healthy eyes and 47 eyes fulfilling diagnostic criteria for DED of various levels of severity were included in this study. The tear film was analyzed for MMP-9 by a commercially available test (InflammaDry; Rapid Pathogen Screening, Inc, Sarasota, FL) detecting MMP-9 levels of more than 40 ng/ml. Symptoms and signs of DED were evaluated using the OSDI questionnaire, TBUT, conjunctival and corneal staining, Schirmer test results without anesthesia, and meibomian gland examination. These findings were correlated to results of the MMP-9 test in tears. Positive MMP-9 results in tears. In 19 of 47 patients confirmed with dry eye (40.4%) and in 3 of 54 controls (5.6%), the MMP-9 results were positive. This difference was statistically significant (P < 0.001). Thus, the MMP-9 results indicated a clinically significant inflammation in 40% of dry eye patients. Positive results correlated well with subjective symptoms of DED evaluated by OSDI (P = 0.001), TBUT of less than 5 seconds (P < 0.013), Schirmer test results (P < 0.001), conjunctival staining (P < 0.001), and corneal staining (P = 0.007). Moreover, MMP-9 results correlated with the number of obstructed meibomian ducts (P = 0.005) and a pathologic meibomian gland secretion (P = 0.001). The MMP-9 results were increased significantly in women (P < 0.001) and in patients with autoimmune disease (P = 0.005), especially Sjögren's syndrome (P = 0.001) and thyroid disease (P = 0.012). Matrix metalloproteinase 9 testing in DED is a valuable new diagnostic tool. It correlated well with other dry eye tests and identified the presence of ocular surface inflammation in 40% of confirmed dry eye patients. It may be especially helpful to identify patients with ocular surface inflammation and autoimmune disease and may facilitate the decision to institute anti-inflammatory treatment in these patients. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Simmich, Joshua; Temple, Shelby E; Collin, Shaun P
2012-03-01
Vertebrate corneas feature a variety of microprojections, to which a tear film adheres. These microprojections are formed by folds in epithelial cell membranes, which increase surface area, stabilise the tear film and enhance movement of nutritional and waste products across cell membranes. Differences in corneal microprojections among vertebrates have been correlated with habitat and differ markedly between terrestrial and aquatic species. This study investigated epithelial microprojections of both the aerial (dorsal) and aquatic (ventral) corneal surfaces of the 'four-eyed fish' Anableps anableps using scanning electron microscopy. The central region of the dorsal cornea, which projects above the water, had a density of 16,387 ± 3,995 cells per mm(2) , while the central region of the ventral cornea (underwater) had a density of 22,428 ± 6,387 cells per mm(2), a difference that suggests an environmental adaptation along the two visual axes. Both corneal surfaces were found to possess microridges rather than microvilli or microplicae characteristic of terrestrial/aerial vertebrates. Microridges were 142 ± 9 nm wide and did not differ (p = 0.757) between dorsal and ventral corneas. Microridges were consistently separated by a distance of 369 ± 9 nm across both corneas. Dorsal-ventral differences in corneal epithelial cell density in Anableps anableps suggest a difference in osmotic pressure of the two corneas. The modest differences in the microprojections indicate that the need to secure the tear film underlying each optical axis is of prime importance, due to the likelihood that a persistent layer of water normally covers both dorsal and ventral corneal surfaces and that maintaining a transparent optical pathway for vision is critical for a species prone to predation from both above and below the water's surface. © 2012 The Authors. Clinical and Experimental Optometry © 2012 Optometrists Association Australia.
A novel TRPM8 agonist relieves dry eye discomfort.
Yang, Jee Myung; Li, Fengxian; Liu, Qin; Rüedi, Marco; Wei, Edward Tak; Lentsman, Michael; Lee, Hyo Seok; Choi, Won; Kim, Seong Jin; Yoon, Kyung Chul
2017-06-26
Physical cooling of the eye surface relieves ocular discomfort, but translating this event to drug treatment of dry eye discomfort not been studied. Here, we synthesized a water-soluble TRPM8 receptor agonist called cryosim-3 (C3, 1-diisopropylphosphorylnonane) which selectively activates TRPM8 (linked to cooling) but not TRPV1 or TRPA1 (linked to nociception) and tested C3 in subjects with mild forms of dry eye disease. A set of 1-dialkylphosphoryalkanes were tested for activation of TRPM8, TRPV1 and TRPA1 receptors in transfected cells. The bioactivity profiles were compared by perioral, topical, and intravenous delivery to anesthetized rats. The selected lead candidate C3 or vehicle (water) was applied with a cotton gauze pad to upper eyelids of patients with dry eye disease (n = 30). Cooling sensation, tear film break-up time (TBUT), basal tear secretion, and corneal staining were evaluated. C3 was then applied four times daily for 2 weeks to patients using a pre-loaded single unit applicator containing 2 mg/mL of C3 in water (n = 20) or water only. TBUT, basal tear secretion, and corneal staining, and three questionnaires surveys of ocular discomfort (VAS scale, OSDI, and CVS symptoms) were analyzed before and at 1 and 2 weeks thereafter. C3 was a selective and potent TRPM8 agonist without TRPV1 or TRPA1 activity. In test animals, the absence of shaking behavior after C3 perioral administration made it the first choice for further study. C3 increased tear secretion in an animal model of dry eye disease and did not irritate when wiped on eyes of volunteers. C3 singly applied (2 mg/ml) produced significant cooling in <5 min, an effecting lasting 46 min with an increase in tear secretion for 60 min. C3 applied for 2 weeks also significantly increased basal tear secretion with questionnaire surveys of ocular discomfort indices clearly showing improvement of symptoms at 1 and 2 weeks. No complaints of irritation or pain were reported by any subject. C3 is a promising candidate for study of TRPM8 function on the eye surface and for relief of dry eye discomfort. ISRCTN24802609 and ISRCTN13359367 . Registered 23 March 2015 and 2 September 2015.
Mechanical tearing of graphene on an oxidizing metal surface.
George, Lijin; Gupta, Aparna; Shaina, P R; Das Gupta, Nandita; Jaiswal, Manu
2015-12-11
Graphene, the thinnest possible anticorrosion and gas-permeation barrier, is poised to transform the protective coatings industry for a variety of surface applications. In this work, we have studied the structural changes of graphene when the underlying copper surface undergoes oxidation upon heating. Single-layer graphene directly grown on a copper surface by chemical vapour deposition was annealed under ambient atmosphere conditions up to 400 °C. The onset temperature of the surface oxidation of copper is found to be higher for graphene-coated foils. Parallel arrays of graphene nanoripples are a ubiquitous feature of pristine graphene on copper, and we demonstrate that these form crucial sites for the onset of the oxidation of copper, particularly for ∼0.3-0.4 μm ripple widths. In these regions, the oxidation proceeds along the length of the nanoripples, resulting in the formation of parallel stripes of oxidized copper regions. We demonstrate from temperature-dependent Raman spectroscopy that the primary defect formation process in graphene involves boundary-type defects rather than vacancy or sp(3)-type defects. This observation is consistent with a mechanical tearing process that splits graphene into small polycrystalline domains. The size of these is estimated to be sub-50 nm.
Ngo, William; Srinivasan, Sruthi; Houtman, Diane; Jones, Lyndon
To determine the combined effect of TheraTears ® Lubricant Eye Drops, TheraTears ® SteriLid Eyelid Cleanser, and TheraTears ® Nutrition on dry eye signs and symptoms. This prospective study enrolled 28 dry eye participants. Participants were instructed to use the Lubricant Eye Drops at least 2-4× a day, SteriLid 1-2× a day, and Nutrition 3 gel caps once a day. Participants were followed up at baseline, 1 month and 3 months. Outcome variables were the Ocular Surface Disease Index (OSDI), Symptom Assessment iN Dry Eye (SANDE) questionnaire, non-invasive tear break-up time (NIBUT), osmolarity, number of meibomian glands blocked (#MG blocked), meibum quality, eyelid margin features, Schirmer's test, tear film lipid layer thickness (LLT), meniscus height, corneal and conjunctival staining. Twenty participants (mean age=43, from 23 to 66, 17F, 3M) completed the study. Participants reported having used, on average, the Lubricant Eye Drop 2.4×/day, the SteriLid 1.1×/day, and the Nutrition 3 gel caps 1×/day. There was a significant change over time (p<0.05) for OSDI (-21.2 points), SANDE (-32.4 points), NIBUT (+0.43s), eyelid margin features (-1.1 grade), meibum quality (-1.0 grade), and #MG blocked (-4.0 glands). By using a combination of TheraTears ® Lubricant Eye Drop, SteriLid, and Nutrition, patients experience significant relief in both dry eye symptoms and signs. Copyright © 2016 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.
Yokoi, N; Sonomura, Y; Kato, H; Komuro, A; Kinoshita, S
2015-09-01
To investigate the long-term results of 3% diquafosol ophthalmic solution as an alternative therapy to existing ophthalmic solutions, including topical immunosuppression, for the treatment of dry eye in patients with Sjögren's syndrome. This study involved 14 female dry-eye patients (mean age: 62.4 years) with Sjögren's syndrome who insufficiently responded to their current therapy. In all patients, 3% diquafosol ophthalmic solution was administered six times daily for 12 months in substitution for artificial tears and sodium hyaluronate ophthalmic solution. Their use of corticosteroid eye drops remained unchanged from that prior to the treatment with diquafosol sodium. The subjective symptoms assessed, and ocular signs including tear meniscus radius and the tear film breakup time, and ocular-surface epithelial damage score were examined at 1, 2, 3, 4, 5, 6, 9, and 12 months after initiating treatment. Among the subjective symptoms, significant improvement was obtained in dryness at 2 months post treatment, in eye fatigue at 1, 2, 3, 4, and 12 months post treatment, and in pain at 1, 2, 6, and 12 months post treatment. Difficulty in opening the eye, foreign body sensation, and redness were also significantly ameliorated at various time-points. The tear meniscus radius and the tear film breakup time were significantly improved throughout the observation period, and the corneal epithelial staining scores were significantly decreased at 3 months post treatment. In dry-eye patients with Sjögren's syndrome, treatment with 3% diquafosol ophthalmic solution improved both symptoms and signs, and that effectiveness was maintained for 12 months.
Black, P
2000-01-01
Cerebrospinal fluid (CSF) leaks are relatively common following spinal or posterior fossa surgery. A midline dural tear in the spine is readily repaired by direct application of a suture. However, far-lateral or ventral dural tears are problematic. Fat is an ideal sealant because it is impermeable to water. In this paper the author reports his experience with using fat grafts for the prevention or repair of CSF leaks and proposes a technique in which a large sheet of fat, harvested from the patient's subcutaneous layer, is used to cover not only the dural tear(s) but all of the exposed dura and is tucked into the lateral recess. This procedure prevents CSF from seeping around the fat, which may be tacked to the dura with a few sutures. Fibrin glue is spread on the surface of the fat and is further covered with Surgicel or Gelfoam. For ventral dural tears (associated with procedures in which disc material is excised), fat is packed into the disc space to seal off the ventral dural leak. Leaks in the posterior fossa are managed similarly to those in the spine. Dural suture lines, following suboccipital or spinal intradural exploration, are prophylactically protected from CSF leakage in the same manner. With one exception, 27 dural tears noted during 1650 spinal procedures were successfully repaired using this technique. There was one case of postoperative CSF leakage in 150 cases in which intradural exploration for tumor or other lesions was undertaken. Both postoperative CSF leaks were controlled by applying additional skin sutures. The use of a fat graft is recommended as a rapid, effective means of prevention and repair of CSF leaks following posterior fossa and spinal surgery.
Tear staining in pigs: a potential tool for welfare assessment on commercial farms.
Telkänranta, H; Marchant-Forde, J N; Valros, A
2016-02-01
Tear staining or chromodacryorrhea refers to a dark stain below the inner corner of the eye, caused by porphyrin-pigmented secretion from the Harderian gland. It has been shown to be a consistent indicator of stress in rats and to correlate with social stress and a barren environment in pigs. The current study was, to our knowledge, the first to test it on commercial pig farms as a potential welfare indicator. The study was carried out on three commercial farms in Finland, in connection to a larger study on the effects of different types of manipulable objects on tail and ear biting and other behavioural parameters. Farm A was a fattening farm, on which 768 growing-finishing pigs were studied in 73 pens. Farm B had a fattening unit, in which 656 growing-finishing pigs were studied in 44 pens, and a farrowing unit, in which 29 sows and their litters totalling 303 piglets were studied in 29 pens. Farm C was a piglet-producing farm, on which 167 breeder gilts were studied in 24 pens. Data collection included individual-level scoring of tear staining; scoring of tail and ear damage in the growing-finishing pigs and breeder gilts; a novel object test for the piglets; and a novel person test for the growing-finishing pigs on Farm B and the breeder gilts on Farm C. On Farm A, tear staining was found to correlate with tail damage scores (n=768, rs=0.14, P<0.001) and ear damage scores (n=768, rs=0.16, P<0.001). In the growing-finishing pigs on Farm B, tear staining of the left eye correlated with tail damage (n=656, rs=0.12, P<0.01) and that of the right eye correlated with ear damage (n=656, rs=0.10, P<0.01). On Farm A, tear-staining sores were lower in the treatment with three different types of manipulable objects as compared with controls (mean scores 3.3 and 3.9, respectively, n=31, F29=4.2, P<0.05). In the suckling piglets on Farm B, tear staining correlated with the latency to approach a novel object (n=29, rp=0.41, P<0.05). Although correlations with tail and ear damage were low, it was concluded that tear staining has promising potential as a new, additional welfare indicator for commercial pig farming. Further research is needed on the mechanisms of tear staining.
Effects of silicone hydrogel contact lenses on ocular surface after Sub-Bowman's Keratomileusis.
Gao, Shaohui; Wu, Junshu; Li, Lili; Wang, Yong; Zhong, Xingwu
2013-11-01
To evaluate the efficacy of silicone hydrogel contact lenses on ocular surface after Sub-Bowman Keratomileusis (SBK). Forty-six patients suffered from myopia underwent a bilateral SBK. Post-operatively, one eye of each patient wore a PureVision contact lens for 24 h as a treated eye and the contralateral eye was as a blank control. Afterwards, corneal fluorescein (FL) staining, tear break-up time (TBUT), schirmer I test (SIT), central corneal thickness (CCT), ocular surface disease index (OSDI), corneal hysteresis (CH), corneal resistance factor (CRF) and corneal flap complications were assessed 1 d (except for CH and CRF), 1 week, 1 month and 3 months postoperatively. Following SBK, in contrast to the control, corneal fluorescein staining of treated eyes were significantly reduced and tear break-up time of treated eyes were significantly improved at 1 d and 1 week after SBK. However, Schirmer I test of treated and control eyes were not different after SBK. Central corneal thickness of treated eyes were significantly thinner than that of control at 1 d after SBK, however, there were no differences at other time points. Ocular surface disease index of treated eyes were obviously alleviated more than that of control at 1 d after SBK, but no differences were found at other visits. Moreover, Corneal hysteresis and corneal resistance factor of treated and un-treated eyes were not different after surgery. And also the rate of corneal flap complications were not different between treated and control eyes after SBK. Silicone hydrogel contact lenses played a positive role in accelerating corneal epithelial healing, enhancing tear film stability and reducing discomfort of patients in the early stage after SBK.
Wang, Chunyan; Peng, Yanli; Pan, Shuling; Li, Li
2014-01-13
To explore the effect of insulin-like growth factor-1 (IGF-1) on corneal surface ultrastructure and nerve regeneration in rabbit models after laser in situ keratomileusis (LASIK). Forty-two healthy New Zealand white rabbits were divided into two groups, the IGF-1 group and the control group, and LASIK surgery was performed. The corneal surface ultrastructure was observed by transmission electron microscopy, and the nerve regeneration was evaluated by counting the newly regenerated nerves at 1 d, 1 w, 2 w, 1 m, 3 m and 6 m after surgery. Dry eye parameters, including the Schirmer I test and tear break-up time, were examined at all time points. The examination of corneal ultrastructure showed that the number of corneal epithelial microvilli in the IGF-1 group was significantly higher than that in the normal saline (NS) group except in the second postoperative week (p<0.05). The observation of corneal nerve regeneration showed that the number of regenerated nerve fibers in the IGF-1 group was higher than the control group at all time points (p<0.05). The parameters of dry eye were significantly higher in the IGF-1 group compared to the control group at all time points except at 1d and 6m after LASIK. IGF-1 can effectively accelerate the early repair of corneal surface ultrastructure and nerve regeneration after LASIK and relieve dry eye symptoms in rabbit eyes. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Modeling the biomechanical and injury response of human liver parenchyma under tensile loading.
Untaroiu, Costin D; Lu, Yuan-Chiao; Siripurapu, Sundeep K; Kemper, Andrew R
2015-01-01
The rapid advancement in computational power has made human finite element (FE) models one of the most efficient tools for assessing the risk of abdominal injuries in a crash event. In this study, specimen-specific FE models were employed to quantify material and failure properties of human liver parenchyma using a FE optimization approach. Uniaxial tensile tests were performed on 34 parenchyma coupon specimens prepared from two fresh human livers. Each specimen was tested to failure at one of four loading rates (0.01s(-1), 0.1s(-1), 1s(-1), and 10s(-1)) to investigate the effects of rate dependency on the biomechanical and failure response of liver parenchyma. Each test was simulated by prescribing the end displacements of specimen-specific FE models based on the corresponding test data. The parameters of a first-order Ogden material model were identified for each specimen by a FE optimization approach while simulating the pre-tear loading region. The mean material model parameters were then determined for each loading rate from the characteristic averages of the stress-strain curves, and a stochastic optimization approach was utilized to determine the standard deviations of the material model parameters. A hyperelastic material model using a tabulated formulation for rate effects showed good predictions in terms of tensile material properties of human liver parenchyma. Furthermore, the tissue tearing was numerically simulated using a cohesive zone modeling (CZM) approach. A layer of cohesive elements was added at the failure location, and the CZM parameters were identified by fitting the post-tear force-time history recorded in each test. The results show that the proposed approach is able to capture both the biomechanical and failure response, and accurately model the overall force-deflection response of liver parenchyma over a large range of tensile loadings rates. Copyright © 2014 Elsevier Ltd. All rights reserved.
Konstas, Anastasios-Georgios; Boboridis, Konstadinos G; Kapis, Paraskevas; Marinopoulos, Konstantinos; Voudouragkaki, Irini C; Panayiotou, Dimitrios; Mikropoulos, Dimitrios G; Pagkalidou, Eirini; Haidich, Anna-Bettina; Katsanos, Andreas; Quaranta, Luciano
2017-01-01
The aim of the present study was to evaluate the 24-h efficacy, tolerability, and ocular surface health with preservative-free (PF) tafluprost and a PF triple drug regimen comprising tafluprost and dorzolamide/timolol fixed combination (DTFC) in open-angle glaucoma patients who were insufficiently controlled with preserved branded or generic latanoprost monotherapy and who exhibited signs or symptoms of ocular surface disease (OSD). Prospective, observer-masked, crossover, comparison. Eligible consecutive open-angle glaucoma patients were randomized to either PF tafluprost or the triple PF regimen for 3 months. They were then crossed over to the opposite therapy for another 3 months. At the end of the latanoprost run-in period and after each PF treatment period, patients underwent habitual 24-h intraocular pressure (IOP) monitoring with Goldmann tonometry in the sitting position (at 10:00, 14:00, 18:00, and 22:00) and Perkins tonometry in the supine position (at 02:00 and 06:00). Tolerability and selected ocular surface parameters were evaluated at baseline and the end of each treatment period. Forty-three open-angle glaucoma patients completed the trial. Mean 24-h IOP on preserved latanoprost was 22.2 ± 3.9 mmHg. Compared with latanoprost monotherapy, PF tafluprost obtained a greater reduction in mean, peak, and fluctuation of 24-h IOP including the 02:00 and 06:00 time points (P < 0.05). With the exception of 24-h fluctuation, the triple PF regimen provided significantly lower IOP parameters than latanoprost or PF tafluprost (P < 0.001). Finally, PF tafluprost therapy displayed significantly improved tear film break-up times (6.7 vs 6.0 s), corneal staining (1.3 vs 2.2), and Schirmer I test results (9.1 vs 8.2 mm) compared with the preserved latanoprost baseline (all P < 0.01). The triple PF regimen demonstrated similar tear film break-up times (6.1 vs 6.0 s) and Schirmer I test results (8.2 vs 8.2 mm) to latanoprost, but revealed a significant improvement in the corneal stain test (1.7 vs 2.2; P < 0.001). In this trial PF tafluprost therapy provided statistically greater 24-h efficacy and improved tolerability compared with preserved latanoprost. The combination of PF tafluprost and PF dorzolamide/timolol fixed combination was statistically and clinically more efficacious than both monotherapies and demonstrated similar ocular surface characteristics to preserved latanoprost monotherapy. ClinicalTrials.gov (NCT02802137). Santen.
The Use of an Intra-Articular Depth Guide in the Measurement of Partial Thickness Rotator Cuff Tears
Carroll, Michael J.; More, Kristie D.; Sohmer, Stephen; Nelson, Atiba A.; Sciore, Paul; Boorman, Richard; Hollinshead, Robert; Lo, Ian K. Y.
2013-01-01
Purpose. The purpose of this study was to compare the accuracy of the conventional method for determining the percentage of partial thickness rotator cuff tears to a method using an intra-articular depth guide. The clinical utility of the intra-articular depth guide was also examined. Methods. Partial rotator cuff tears were created in cadaveric shoulders. Exposed footprint, total tendon thickness, and percentage of tendon thickness torn were determined using both techniques. The results from the conventional and intra-articular depth guide methods were correlated with the true anatomic measurements. Thirty-two patients were evaluated in the clinical study. Results. Estimates of total tendon thickness (r = 0.41, P = 0.31) or percentage of thickness tears (r = 0.67, P = 0.07) using the conventional method did not correlate well with true tendon thickness. Using the intra-articular depth guide, estimates of exposed footprint (r = 0.92, P = 0.001), total tendon thickness (r = 0.96, P = 0.0001), and percentage of tendon thickness torn (r = 0.88, P = 0.004) correlated with true anatomic measurements. Seven of 32 patients had their treatment plan altered based on the measurements made by the intra-articular depth guide. Conclusions. The intra-articular depth guide appeared to better correlate with true anatomic measurements. It may be useful during the evaluation and development of treatment plans for partial thickness articular surface rotator cuff tears. PMID:23533789
López-de la Rosa, Alberto; Pinto-Fraga, José; Blázquez Arauzo, Francisco; Urbano Rodríguez, Rubén; González-García, María J
2017-11-01
To evaluate the safety and efficacy of a new 0.3% hyaluronic acid artificial tear compared with 0.9% saline solution (0.9% NaCl) in moderate-to-severe dry eye patients after 1 month's use. A total of 16 patients with moderate-to-severe dry eye were included in this crossover study. After a 1-week washout period, patients used the experimental (Visaid 0.3%) or control solution (0.9% NaCl), selected randomly, applying three to eight drops daily for a month. After another washout period, patients used the other solution in the same way. Percentage of change (ΔY) was calculated and analyzed for (1) safety variables: visual acuity, intraocular pressure, and ophthalmoscopy evaluation; (2) efficacy variable: Ocular Surface Disease Index (OSDI) questionnaire; and (3) secondary variables: biomicroscopy findings, fluorescein corneal staining, lissamine green conjunctival staining, tear breakup time (TBUT), contrast sensitivity, Schirmer test, and subject satisfaction. There were no significant differences in the safety parameters for either solution. After using Visaid 0.3%, patients showed significant improvements in OSDI score (ΔY: -9.66%±10.90), tarsal hyperemia (ΔY: -16.67%±27.89), corneal staining extension (ΔY: -34.90%±42.41), TBUT (ΔY: 13.98%±26.19), and subjective satisfaction (ΔY: 38.06%±47.06). When using 0.9% NaCl, Schirmer test results were significantly worse (ΔY: -11.47%±19.27). A significant difference between the 2 solutions was found in TBUT (ΔY: 13.98%±26.19 vs. 10.15%±42.34, respectively; P=0.0214). Visaid 0.3% is a safe product with some benefits over 0.9% NaCl in reducing ocular symptoms and improving some ocular signs in patients with moderate-to-severe dry eye.
Electrostatic Manipulation of Graphene On Graphite
NASA Astrophysics Data System (ADS)
Untiedt, Carlos; Rubio-Verdu, Carmen; Saenz-Arce, Giovanni; Martinez-Asencio, Jesús; Milan, David C.; Moaied, Mohamed; Palacios, Juan J.; Caturla, Maria Jose
2015-03-01
Here we report the use of a Scanning Tunneling Microscope (STM) under ambient and vacuum conditions to study the controlled exfoliation of the last layer of a graphite surface when an electrostatic force is applied from a STM tip. In this work we have focused on the study of two parameters: the applied voltage needed to compensate the graphite interlayer attractive force and the one needed to break atomic bonds to produce folded structures. Additionally, we have studied the influence of edge structure in the breaking geometry. Independently of the edge orientation the graphite layer is found to tear through the zig-zag direction and the lifled layer shows a zig-zag folding direction. Molecular Dinamics simulations and DFT calculations have been performed to understand our results, showing a strong correlation with the experiments. Comunidad Valenciana through Prometeo project.
NASA Astrophysics Data System (ADS)
Booth-Rea, Guillermo; Pérez-Peña, Vicente; Azañón, José Miguel; de Lis Mancilla, Flor; Morales, Jose; Stich, Daniel; Giaconia, Flavio
2014-05-01
Most of the geological features of the Betics and Rif have resulted from slab tearing, edge delamination and punctual slab breakoff events between offset STEP faults. New P-reciever function data of the deep structure under the Betics and Rif have helped to map the deep boundaries of slab tearing and rupture in the area. Linking surface geological features with the deep structure shows that STEP faulting under the Betics occurred along ENE-WSW segments offset towards the south, probably do to the westward narrowing of the Tethys slab. The surface expression of STEP faulting at the Betics consists of ENE-WSW dextral strike-slip fault segments like the Crevillente, Alpujarras or Torcal faults that are interrupted by basins and elongated extensional domes were exhumed HP middle crust occurs. Exhumation of deep crust erases the effects of strike-slip faulting in the overlying brittle crust. Slab tearing affected the eastern Betics during the Tortonian to Messinian, producing the Fortuna and Lorca basins, and later propagated westward generating the end-Messinian to Pleistocene Guadix-Baza basins and the Granada Pliocene-Pleistocene depocentre. At present slab tearing is occurring beneath the Málaga depression, where the Torcal dextral strike-slip fault ends in a region of active distributed shortening and where intermediate depth seismicity occurs. STEP fault migration has occurred at average rates between 2 and 4 cm/yr since the late Miocene, producing a wave of alternating uplift-subsidence pulses. These initiate with uplift related to slab flexure, subsidence related to slab-pull, followed by uplift after rupture and ending with thermal subsidence. This "yo-yo" type tectonic evolution leads to the generation of endorheic basins that later evolve to exhorheic when they are uplifted and captured above the region where asthenospheric upwelling occurs.
Response of the Aging Eye to First Day of Modern Material Contact Lens Wear.
Lafosse, Edouard; Martínez-Albert, Noelia; Wolffsohn, James S W; Cerviño, Alejandro; García-Lázaro, Santiago
2018-06-25
To investigate the ocular surface of an aged population wearing a daily disposable contact lens (CL) over their 1st day of wear. Forty eyes from 40 presbyopic subjects were fitted a daily CL (Delefilcon A). Tear osmolarity, tear meniscus area (TMA), and ocular surface aberrations (total higher-order root mean square [RMS]) were assessed at baseline (t0), at 20 min (t1) and after 8 hr (t2) of wear. Fluorescein corneal and conjunctival staining and tear breakup time (TBUT) were performed at t0 and t2. No statistically significant changes were found between t0, t1, and t2 for TMA and between t0 and t2 for fluorescein corneal and conjunctival staining. Tear breakup time worsened by the end of the day from 10.4±0.4 sec t0 to 9.0±0.3 sec t2 (P<0.05). Osmolarity showed significant changes between t0 306.9±2.3 mOsm/L and t1 312.4±2.4 mOsmol/L (P=0.02) but returned to baseline values at 8 hr (310.40±2.26 mOsm/L; P=0.09). Total higher-order RMS showed significant changes between t0 0.38±0.02 μm and t1 0.61±0.04 μm (P≤0.001) and between t0 and t2 0.64±0.41 μm (P≤0.001). Delefilcon A may induce measures changes (osmolarity and TBUT values) in a presbyopic population; however, TMA and vital staining were maintained at the baseline level over the day.
Simmons, Peter A; Liu, Haixia; Carlisle-Wilcox, Cindy; Vehige, Joseph G
2015-01-01
Purpose To evaluate and compare the efficacy and safety of two investigational artificial tear formulations (CHO-1 and CHO-2) containing carmellose sodium, hyaluronic acid at different concentrations, and osmoprotectants, with a standard carmellose sodium-containing formulation (Refresh Tears [RT]) in the treatment of dry eye disease. Subjects and methods In this 3-month, double-masked, multicenter study, subjects (n=305) were randomized 1:1:1 to receive CHO-1, CHO-2, or RT, used as needed but at least twice daily. The primary endpoint was change in ocular surface disease index (OSDI) score from baseline to day 90. Other key outcomes included symptoms evaluated on a visual analog scale, corneal and conjunctival staining, and adverse events. Results OSDI scores and dry eye symptoms showed a rapid and sustained reduction from baseline in each group. Both CHO-1 and CHO-2 met the primary efficacy endpoint of noninferiority to RT in day 90 OSDI score change from baseline. OSDI ocular symptoms subscale improved more with CHO-1 than CHO-2 (P=0.048). In subjects with clinically relevant baseline ocular surface staining (>14 total score of a maximum of 55), day 90 improvements were greater with CHO-1 and CHO-2 than RT (P≤0.044). Day 90 improvements in OSDI ocular symptoms subscale scores were also greater with CHO-1 than RT (P<0.007) in subjects with clinically relevant ocular staining. All treatments were well tolerated. Conclusion Both combination artificial tear formulations were efficacious and well tolerated in subjects with dry eye. CHO-1 demonstrated the best performance in improving ocular symptoms and reducing ocular staining in this heterogeneous study population. PMID:25931807
Ocular Surface and Tear Film Changes in Older Women Working with Computers.
Ribelles, Alfredo; Galbis-Estrada, Carmen; Parras, Maria A; Vivar-Llopis, Bárbara; Marco-Ramírez, Carla; Diaz-Llopis, Manuel
2015-01-01
The aim of this work is to investigate changes in the ocular surface (OS) and tear film (TF) by means of questionnaire-based subjective symptoms, TF break-up time, Schirmer test, and TF analysis in women working with computers and to analyze the effects of the oral supplementation with antioxidants/omega 3 fatty acids (A/ω3) in the OS outcomes. Women aged 40-65 years (n = 148) were recruited at the Administrative Offices of Valencia (Spain) and distributed into two age groups, 40-52 years (AGE1; n = 87) and 53-65 years (AGE2; n = 61), and then subdivided according to being (or not) computer users (CUG; NCUG) during the workday. Homogeneous subgroups were randomly assigned (or not) to the daily intake of three pills of A/ω3 for three months. At baseline and at the end of follow-up, personalized interviews and ocular examination were done. Reflex tear samples were collected from the inferior meniscus and processed for a multiplexed particle-based flow cytometry assay to measure proinflammatory molecules. Statistics were performed using the SPSS 15.0 program. The OS pathology was clinically evident in the AGE1-CUG (33%) versus the AGE2-CUG (64%) of women. Significantly higher interleukins-1β and -6 tear levels were found in the AGE1 versus the AGE2 women employees (P = 0.006 and P = 0.001, resp.), as well as in the CUG versus the NCUG (P = 0.001 and P = 0.000, resp.). Supplementation with A/ω3 positively influenced the OS pathology as manifested by the amelioration of the clinical signs/symptoms related to computer uses. Strategies involving a safe environment and oral micronutrient supplements may be managed within eye-care standards in older women.
Ocular Surface and Tear Film Changes in Older Women Working with Computers
Ribelles, Alfredo; Parras, Maria A.; Vivar-Llopis, Bárbara; Marco-Ramírez, Carla; Diaz-Llopis, Manuel
2015-01-01
The aim of this work is to investigate changes in the ocular surface (OS) and tear film (TF) by means of questionnaire-based subjective symptoms, TF break-up time, Schirmer test, and TF analysis in women working with computers and to analyze the effects of the oral supplementation with antioxidants/omega 3 fatty acids (A/ω3) in the OS outcomes. Women aged 40–65 years (n = 148) were recruited at the Administrative Offices of Valencia (Spain) and distributed into two age groups, 40–52 years (AGE1; n = 87) and 53–65 years (AGE2; n = 61), and then subdivided according to being (or not) computer users (CUG; NCUG) during the workday. Homogeneous subgroups were randomly assigned (or not) to the daily intake of three pills of A/ω3 for three months. At baseline and at the end of follow-up, personalized interviews and ocular examination were done. Reflex tear samples were collected from the inferior meniscus and processed for a multiplexed particle-based flow cytometry assay to measure proinflammatory molecules. Statistics were performed using the SPSS 15.0 program. The OS pathology was clinically evident in the AGE1-CUG (33%) versus the AGE2-CUG (64%) of women. Significantly higher interleukins-1β and -6 tear levels were found in the AGE1 versus the AGE2 women employees (P = 0.006 and P = 0.001, resp.), as well as in the CUG versus the NCUG (P = 0.001 and P = 0.000, resp.). Supplementation with A/ω3 positively influenced the OS pathology as manifested by the amelioration of the clinical signs/symptoms related to computer uses. Strategies involving a safe environment and oral micronutrient supplements may be managed within eye-care standards in older women. PMID:26557673
Sengor, Tomris; Aydin Kurna, Sevda; Ozbay, Nurver; Ertek, Semahat; Aki, Suat; Altun, Ahmet
2012-01-01
To evaluate ocular surface changes in long-term silicone hydrogel contact lens wearers. Thirty patients were included in this study. Twenty patients (40 eyes) using contact lenses constituted group 1 and 10 (20 eyes) volunteers constituted group 2. The duration of average contact lens usage was 7.74 ± 3.3 years. Ocular surface was evaluated by surface staining, tear film break-up time (TBUT), Schirmer I test, and conjunctival impression cytology with color-coded mapping technique and by the Ocular Surface Disease Index (OSDI). The mean break-up time was lower and staining scores were higher in group 1 (p<0.001) but Schirmer values were not significantly different from group 2 (p>0.05). The mean OSDI score was 34.59 ± 11.93 to 19.28 ± 6.7 in group 1 and 2. Increased metaplastic predominant changes of grade II and III were observed in the interpalpebral and perilimbal areas in group 1. Significant correlations were observed in TBUT, cornea staining, and grade II to grade III metaplasia ratios between duration of the lens usage and contact lens wear time in a day. Silicone hydrogel lenses produce significant changes on tear film and impression cytology of the ocular surface in long-term use.
A comparison of basal and eye-flush tears for the analysis of cat tear proteins.
Petznick, Andrea; Evans, Margaret D M; Madigan, Michele C; Markoulli, Maria; Garrett, Qian; Sweeney, Deborah F
2011-02-01
To identify a rapid and effective tear collection method providing sufficient tear volume and total protein content (TPC) for analysis of individual proteins in cats. Domestic adult short-haired cats (12-37 months; 2.7-6.6 kg) were used in the study. Basal tears without stimulation and eye-flush tears after instillation of saline (10 μl) were collected using microcapillary tubes from animal eyes either unwounded control or wounded with 9-mm central epithelial debridement giving four groups with n = 3. Tear comparisons were based on total time and rate for tear collection, TPC using micro bicinchoninic acid (BCA), tear immunoglobulin A (IgA), total matrix-metalloproteinase (MMP)-9 concentration using sandwich enzyme-linked immunosorbent assay (ELISA) and MMP-9 activity. Eye-flush tears were collected significantly faster than basal tears in wounded eyes with higher rates for tear collection in unwounded control and wounded eyes. TPC was significantly lower in eye-flush tears compared to basal tears. The relative proportion of tear IgA normalized to TPC (% IgA of TPC) was not significantly different between basal and eye-flush tears. In unwounded control eyes, MMP-9 was slightly higher in eye-flush than in basal tears; activity of MMP-9 in both tear types was similar. In wounded eyes, eye-flush tears showed highest MMP-9 levels and activity on Day 1, which subsequently decreased to Day 7. MMP-9 activity in basal tears from wounded eyes did not display changes in expression. Eye-flush tears can be collected rapidly providing sufficient tear volume and TPC. This study also indicates that eye-flush tears may be more suitable than basal tears for the analysis of MMPs following corneal wounding. © 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.
Potential of near-infrared spectroscopy for quality evaluation of cattle leather.
Braz, Carlos Eduardo M; Jacinto, Manuel Antonio C; Pereira-Filho, Edenir R; Souza, Gilberto B; Nogueira, Ana Rita A
2018-05-09
Models using near-infrared spectroscopy (NIRS) were constructed based on physical-mechanical tests to determine the quality of cattle leather. The following official parameters were used, considering the industry requirements: tensile strength (TS), percentage elongation (%E), tear strength (TT), and double hole tear strength (DHS). Classification models were constructed with the use of k-nearest neighbor (kNN), soft independent modeling of class analogy (SIMCA), and partial least squares-discriminant analysis (PLS-DA). The evaluated figures of merit, accuracy, sensitivity, and specificity presented results between 85% and 93%, and the false alarm rates from 9% to 14%. The model with lowest validation percentage (92%) was kNN, and the highest was PLS-DA (100%). For TS, lower values were obtained, from 52% for kNN and 74% for SIMCA. The other parameters %E, TT, and DHS presented hit rates between 87 and 100%. The abilities of the models were similar, showing they can be used to predict the quality of cattle leather. Copyright © 2018 Elsevier B.V. All rights reserved.
Dry Eye Syndrome in Non-Exophthalmic Graves' Disease.
Bruscolini, A; Abbouda, A; Locuratolo, N; Restivo, L; Trimboli, P; Romanelli, F
2015-01-01
The present study aims to assess qualitative and quantitative characteristics of tear film and corneal related impairment and to evaluate the quality of life in a cohort of non-exophthalmic Graves' disease (GD) patients. The series comprised 50 eyes from 25 newly diagnosed GD patients with no proptosis. As control group, 56 eyes of 28 thyroid disease-free subjects were enrolled. The results of Schirmer I and II, break-up time, and Oxford scheme showed a significant difference between GD and controls. By ocular surface disease index (OSDI) questionnaire, eleven (44%) GD patients had normal ocular surface, while two (8%) had mild, four (16%) had moderate, and eight (32%) had severe dry eye. The mean score of the OSDI in the GD group was significantly (p < 0.001) higher with respect to the control group. This study shows that the tear film and cornea are damaged in newly non-exophthalmic GD subjects.
The Prevalence of Dry Eye and Sjögren Syndrome in Patients with Migraine.
Sarac, Ozge; Kosekahya, Pinar; Yildiz Tasci, Yelda; Keklikoglu, Hava D; Deniz, Orhan; Erten, Şükran; Çağıl, Nurullah
2017-06-01
To evaluate the presence of dry eye and primary Sjögren syndrome (SS) in patients with migraine. In total, 46 eyes of 46 patients with migraine (group 1) and 50 eyes of 50 healthy subjects (group 2) were included in this study. Detailed ophthalmologic, neurologic and rheumatologic examination were performed on all participants. Ocular surface disease index questionnaire, tear function tests, visual analog scale for pain, serologic analysis were also performed. Dry eye symptoms and findings were significantly higher and more severe in group 1 when compared with group 2. Primary SS was not found in any of the participants. The migraine lifetime duration was negatively correlated with the tear function tests while it was positively correlated with the ocular surface disease index scores. Dry eye symptoms and findings are higher in migraine patients when compared with the healthy subjects without the presence of Sjögren syndrome.
New insights into the diagnosis and treatment of dry eye.
Dogru, Murat; Tsubota, Kazuo
2004-04-01
Over the past decade, numerous advances have been made in relation to dry eye diagnostic markers, technologies, and treatment options. The mainstay of treatment of dry eye is the use of artificial tear solutions and punctum plugs. A goal is the development of agents that provide symptomatic treatment and, at the same time, improve ocular surface keratinization. It is the authors' opinion that the functional visual acuity tester and the new tear stability analysis system will be widely used to improve diagnosis and evaluate treatment outcomes in KCS. Advances in treatment will utilize anti-inflammatory agents, immune suppressants such as Cyclosporin A and FK-506, growth hormones, androgens, topical mucins and ocular surface stimulating drugs, like INS365. Although aqueous-deficient dry eye is most commonly not associated with Sjogren syndrome (SS), aqueous-deficient dry eye is often most severe in patients with SS; thus, this article focuses mainly on SS-associated dry eye.
NASA Astrophysics Data System (ADS)
Bowman, C.; Gibson, K. J.; La Haye, R. J.; Groebner, R. J.; Taylor, N. Z.; Grierson, B. A.
2014-10-01
A Bayesian inference framework has been developed for the DIII-D charge-exchange recombination (CER) system, capable of computing probability distribution functions (PDFs) for desired parameters. CER is a key diagnostic system at DIII-D, measuring important physics parameters such as plasma rotation and impurity ion temperature. This work is motivated by a case in which the CER system was used to probe the plasma rotation radial profile around an m/n = 2/1 tearing mode island rotating at ~ 1 kHz. Due to limited resolution in the tearing mode phase and short integration time, it has proven challenging to observe the structure of the rotation profile across the island. We seek to solve this problem by using the Bayesian framework to improve the estimation accuracy of the plasma rotation, helping to reveal details of how it is perturbed in the magnetic island vicinity. Examples of the PDFs obtained through the Bayesian framework will be presented, and compared with results from a conventional least-squares analysis of the CER data. Work supported by the US DOE under DE-FC02-04ER54698 and DE-AC02-09CH11466.
Vandermeer, G; Chamy, Y; Pisella, P-J
2018-02-01
Dry eye is defined by a tear film instability resulting in variable but systematic fluctuations in quality of vision. Variability in optical quality can be demonstrated using a double pass aberrometer such as the Optical Quality Analyzing System, Visiometrics (OQAS). The goal of this work is to compare fluctuations in objective quality of vision measured by OQAS between treatment with normal saline eye drops and treatment with carmellose 0.5% and hyaluronic acid 0.1% (Optive Fusion [OF], Allergan) in patients with moderate dry eye syndrome. Optical quality was measured by evaluating the variations in the Optical Scattering Index (OSI) over 20seconds using the OQAS. Inclusion criteria were dry eye syndrome with an ocular surface disease index (OSDI) score >23 treated only with artificial tears. The patients were their own controls: OF in one eye and normal saline in the fellow eye. The choice of the subject eye and control eye was determined in a randomized fashion. OSI variations were measured in each eye before instillation, 5minutes and 2hours after instillation. The primary endpoint was OSI fluctuation over 20seconds of measurement. Secondary endpoints were the number of blinks and patient preference (preferred eye). Preliminary results were obtained on 19 patients. Average OSDI score was 36.8. Visual acuity was 10/10 with no significant difference between the two eyes. Prior to instillation, there was no significant difference between "normal saline" and "OF" eyes in terms of OSI, OSI variability or number of blinks. In the normal saline eye, there were no significant variations in mean OSI, OSI variability, OSI slope, or number of blinks. However, in the "OF" eye, there was a significant variation between initial and 2-hour OSI variability (0.363 versus 0.204, P<0.05), the average slope of OSI (0.04 versus 0.01, P<0.05) and the number of blinks (4.2 versus 2.8, P<0.05). Among the patients, 65% preferred the OF eye, 24% did not have a preference, and 11% preferred the normal saline eye. Objective quality of vision measured by OQAS is an interesting parameter for evaluating the effectiveness of a lacrimal substitute. The purpose of artificial tears is, among other things, to provide comfort and a reduction of dry eye symptoms such as poor quality of vision. This study demonstrates that 0.5% carmellose and 0.1% hyaluronic acid allowed better stabilization of the tear film and thus a significant improvement in the quality of vision compared to normal saline. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Vandermeer, G; Chamy, Y; Pisella, P-J
2018-03-01
Dry eye is defined by a tear film instability resulting in variable but systematic fluctuations in the quality of vision. Variability in optical quality can be demonstrated using a double pass aberrometer such as the OQAS (Optical Quality Analyzing System, Visiometrics). The goal of this work is to compare fluctuations in objective quality of vision measured by OQAS between treatment with normal saline eye drops and treatment with carmellose 0.5% and hyaluronic acid 0.1% (Optive Fusion [OF], Allergan) in patients with moderate dry eye syndrome. Optical quality was measured by evaluating the variations in the Optical Scattering Index (OSI) over 20seconds using the OQAS. Inclusion criteria were dry eye syndrome with an Ocular Surface Disease Index (OSDI) score>23 treated only with artificial tears. The patients were their own controls: OF in one eye and normal saline in the fellow eye. The choice of the subject eye and control eye was determined in a randomized fashion. OSI variations were measured in each eye before instillation, 5minutes and 2hours after instillation. The primary endpoint was OSI fluctuation over 20seconds of measurement. Secondary endpoints were the number of blinks and patient's preference (preferred eye). Preliminary results were obtained on 19 patients. Average OSDI score was 36.8. Visual acuity was 10/10 with no significant difference between the two eyes. Prior to instillation, there was no significant difference between "normal saline" and "OF" eyes in terms of OSI, OSI variability or number of blinks. In the normal saline eye, there was no significant variation in mean OSI, OSI variability, OSI slope, or number of blinks. However, in the "OF" eye, there was a significant variation between initial and 2-hour OSI variability (0.363 versus 0.204; P<0.05), the average slope of OSI (0.04 versus 0.01; P<0.05) and the number of blinks (4.2 versus 2.8; P<0.05). Sixty-five percent of patients preferred the OF eye, 24% did not have a preference, and 11% preferred the normal saline eye. Objective quality of vision measured by OQAS is an interesting parameter for evaluating the effectiveness of a lacrimal substitute. The purpose of artificial tears is, among other things, to provide comfort and a reduction of dry eye symptoms such as poor quality of vision. This study demonstrates that 0.5% carmellose and 0.1% hyaluronic acid allowed better stabilization of the tear film and thus a significant improvement in the quality of vision compared to normal saline. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
De Smet, A A; Graf, B K
1994-04-01
MR imaging of the knee is a valuable technique for diagnosing meniscal tears, but some tears found at arthroscopy are not shown on MR imaging. The purpose of this study was to determine whether or not tears were more frequently missed in the presence of an anterior cruciate ligament tear or when tears had certain locations or configurations. We reviewed the original MR reports and surgical records of 400 patients who had both an MR examination and arthroscopy of the knee. Using chi 2 analysis, we examined how the sensitivity for detecting meniscal tears varied with the presence of a tear of the anterior cruciate ligament, with the location of the tear within the meniscus, and among six configurations of meniscal tears. We also studied whether sensitivity decreased with an increasing delay between MR examination and arthroscopy. In the presence of a tear of the anterior cruciate ligament, the sensitivity decreased from 0.97 to 0.88 (p = .016) for medial meniscal tears and from 0.94 to 0.69 (p = .0005) for lateral tears. The overall sensitivity for lateral meniscal tears was significantly less for posterior (p = .001) and peripheral (p = .005) tears than for other tear locations or configurations. The sensitivities did not significantly differ between tear locations and configurations in the medial meniscus or with an increasing delay until arthroscopy. Patients with a torn anterior cruciate ligament were more likely to have peripheral tears of the medial meniscus (p = .00004) and posterior (p = .0004) and peripheral (p = .04) tears of the lateral meniscus. Because of their location and configuration, meniscal tears associated with an anterior cruciate ligament injury are more difficult to detect on MR images than are tears in knees with an intact ligament. If a tear of the anterior cruciate ligament is detected, special attention should be given to the subtle peripheral tears that may be present in either meniscus, but most commonly in the posterior horn of the lateral meniscus. These tears are especially difficult to detect on MR images.
Tseng, Ching-Li; Hung, Ya-Jung; Chen, Zhi-Yu; Fang, Hsu-Wei; Chen, Ko-Hua
2016-01-01
Dry eye syndrome (DES) is a common eye disease. Artificial tears (AT) are used to treat DES, but they are not effective. In this study, we assessed the anti-inflammatory effect of AT containing epigallocatechin gallate (EGCG) and hyaluronic acid (HA) on DES. Human corneal epithelial cells (HCECs) were used in the WST-8 assay to determine the safe dose of EGCG. Lipopolysaccharide-stimulated HCECs showing inflammation were treated with EGCG/HA. The expression of IL-1ß, IL-6, IL-8, and TNF-α was assessed by real-time PCR and AT physical properties such as the viscosity, osmolarity, and pH were examined. AT containing EGCG and HA were topically administered in a rabbit DES model established by treatment with 0.1% benzalkonium chloride (BAC). Tear secretion was assessed and fluorescein, H&E, and TUNEL staining were performed. Inflammatory cytokine levels in the corneas were also examined. The non-toxic optimal concentration of EGCG used for the treatment of HCECs in vitro was 10 μg/mL. The expression of several inflammatory genes, including IL-1ß, IL-6, IL-8, and TNF-α, was significantly inhibited in inflamed HCECs treated with 10 μg/mL EGCG and 0.1% (w/v) HA (E10/HA) compared to that in inflamed HCECs treated with either EGCG or HA alone. AT containing E10/HA mimic human tears, with similar osmolarity and viscosity and a neutral pH. Fluorescence examination of the ocular surface of mouse eyes showed that HA increased drug retention on the ocular surface. Topical treatment of DES rabbits with AT plus E10/HA increased tear secretion, reduced corneal epithelial damage, and maintained the epithelial layers and stromal structure. Moreover, the corneas of the E10/HA-treated rabbits showed fewer apoptotic cells, lower inflammation, and decreased IL-6, IL-8, and TNF-α levels. In conclusion, we showed that AT plus E10/HA had anti-inflammatory and mucoadhesive properties when used as topical eye drops and were effective for treating DES in rabbits.
Comparative effect of lens care solutions on blink rate, ocular discomfort and visual performance.
Yang, Shun-nan; Tai, Yu-chi; Sheedy, James E; Kinoshita, Beth; Lampa, Matthew; Kern, Jami R
2012-09-01
To help maintain clear vision and ocular surface health, eye blinks occur to distribute natural tears over the ocular surface, especially the corneal surface. Contact lens wearers may suffer from poor vision and dry eye symptoms due to difficulty in lens surface wetting and reduced tear production. Sustained viewing of a computer screen reduces eye blinks and exacerbates such difficulties. The present study evaluated the wetting effect of lens care solutions (LCSs) on blink rate, dry eye symptoms, and vision performance. Sixty-five adult habitual soft contact lens wearers were recruited to adapt to different LCSs (Opti-free, ReNu, and ClearCare) in a cross-over design. Blink rate in pictorial viewing and reading (measured with an eyetracker), dry eye symptoms (measured with the Ocular Surface Disease Index questionnaire), and visual discrimination (identifying tumbling E) immediately before and after eye blinks were measured after 2 weeks of adaption to LCS. Repeated measures anova and mixed model ancova were conducted to evaluate effects of LCS on blink rate, symptom score, and discrimination accuracy. Opti-Free resulted in lower dry eye symptoms (p = 0.018) than ClearCare, and lower spontaneous blink rate (measured in picture viewing) than ClearCare (p = 0.014) and ReNu (p = 0.041). In reading, blink rate was higher for ClearCare compared to ReNu (p = 0.026) and control (p = 0.024). Visual discrimination time was longer for the control (daily disposable lens) than for Opti-Free (p = 0.007), ReNu (p = 0.009), and ClearCare (0.013) immediately before the blink. LCSs differently affected blink rate, subjective dry eye symptoms, and visual discrimination speed. Those with wetting agents led to significantly fewer eye blinks while affording better ocular comfort for contact lens wearers, compared to that without. LCSs with wetting agents also resulted in better visual performance compared to wearing daily disposable contact lenses. These presumably are because of improved tear film quality. © 2012 The College of Optometrists.
Martinez, Jaime D; Galor, Anat; Ramos-Betancourt, Nallely; Lisker-Cervantes, Andrés; Beltrán, Francisco; Ozorno-Zárate, Jorge; Sánchez-Huerta, Valeria; Torres-Vera, Marco-Antonio; Hernández-Quintela, Everardo
2016-01-01
The purpose of this study was to ascertain the frequency and risk factors of dry eye (DE) among patients attending a tertiary care ophthalmology center in Mexico. Approximately 338 consecutive new patients attending a tertiary care ophthalmology center in Mexico City underwent an ocular surface examination, which included tear film break-up time, fluorescein corneal staining, Schirmer's test, and evaluation of meibum quality. Symptoms of DE were evaluated by the Ocular Surface Disease Index and Dry Eye Questionnaire-5. Information on demographics, exposures, past medical and ocular history, and medications was also collected. The frequency of severe DE symptoms was found to be 43% based on the Ocular Surface Disease Index and 30% based on Dry Eye Questionnaire-5. Risk factors significantly associated with increased DE symptoms included dry mouth and gastrointestinal ulcer medications. With regard to signs, aqueous tear deficiency was a less-frequent finding (22%) in our population than evaporative deficiency (94%). Risk factors associated with aqueous tear deficiency were dry mouth and diuretic use. No risk factors were associated with evaporative deficiency. Risk factors associated with meibomian gland dysfunction included old age, male sex, arthritis, and use of an antihypertensive. The only risk factor associated with corneal staining was dry mouth. This is the first study to demonstrate the frequency of symptomatic and clinical DE in a tertiary care ophthalmology center in Mexico. The frequency of DE ranged from 30% using a symptomatic definition to 94% using objective measures. Different risk factors were found for different aspects of DE, suggesting differing underlying pathophysiologies behind different DE subtypes.
A mouse dry eye model induced by topical administration of benzalkonium chloride.
Lin, Zhirong; Liu, Xiaochen; Zhou, Tong; Wang, Yihui; Bai, Li; He, Hui; Liu, Zuguo
2011-01-25
To develop a dry eye model of mouse induced by topical administration of benzalkonium chloride (BAC) and investigate the possible mechanisms. BAC at concentration of 0.2% was applied to the mouse ocular surface for 7 days. Phenol red thread tear test, tear break-up time (BUT) test, corneal inflammatory index scoring, fluorescein and rose bengal test were performed to evaluate the toxic effects of BAC on the ocular surface. Global specimens were collected on day (D) 7 and labeled with a series of antibodies including cytokeratin 10 (K10) and mucin 5AC (MUC5AC). Apoptosis of ocular surface epithelium was evaluated by in situ terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) assay. Histologic analysis and transmission electron microscopy (TEM) were performed on D7. BAC at a concentration of 0.2% successfully induced a dry eye condition with decreased tear volume and BUTs, increased corneal fluorescein and rose bengal scores. The Inflammatory index was increased in accompaniment with higher tumor necrosis factor-α (TNF-α) expression and more inflammatory infiltration in the cornea. Immunolabeling revealed positive K10 expression in BAC-treated corneal epithelium and fewer MUC5AC-positive cells in the BAC-treated conjunctival fornix. TUNEL assay showed more apoptotic cells in the corneal basal epithelium. TEM showed that the size and intervals of the microvillis were both reduced in the corneal epithelium. Topical administration of 0.2% BAC in mouse induces changes resembling that of dry eye syndrome in humans, and thus, represents a novel model of dry eye.
A mouse dry eye model induced by topical administration of benzalkonium chloride
Lin, Zhirong; Liu, Xiaochen; Zhou, Tong; Wang, Yihui; Bai, Li; He, Hui
2011-01-01
Purpose To develop a dry eye model of mouse induced by topical administration of benzalkonium chloride (BAC) and investigate the possible mechanisms. Methods BAC at concentration of 0.2% was applied to the mouse ocular surface for 7 days. Phenol red thread tear test, tear break-up time (BUT) test, corneal inflammatory index scoring, fluorescein and rose bengal test were performed to evaluate the toxic effects of BAC on the ocular surface. Global specimens were collected on day (D) 7 and labeled with a series of antibodies including cytokeratin 10 (K10) and mucin 5AC (MUC5AC). Apoptosis of ocular surface epithelium was evaluated by in situ terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) assay. Histologic analysis and transmission electron microscopy (TEM) were performed on D7. Results BAC at a concentration of 0.2% successfully induced a dry eye condition with decreased tear volume and BUTs, increased corneal fluorescein and rose bengal scores. The Inflammatory index was increased in accompanyment with higher tumor necrosis factor-α (TNF-α) expression and more inflammatory infiltration in the cornea. Immunolabeling revealed positive K10 expression in BAC-treated corneal epithelium and fewer MUC5AC-positive cells in the BAC-treated conjunctival fornix. TUNEL assay showed more apoptotic cells in the corneal basal epithelium. TEM showed that the size and intervals of the microvillis were both reduced in the corneal epithelium. Conclusions Topical administration of 0.2% BAC in mouse induces changes resembling that of dry eye syndrome in humans, and thus, represents a novel model of dry eye. PMID:21283525
Venkat, Gorthi; Moon, Young Lae; Na, Woong Chae; So, Keum Young
2009-10-01
During arthroscopic procedures, leakage of irrigation fluid into surrounding tissue planes is a frequently noticed phenomenon usually clinically asymptomatic and resolving within 12 hours postoperatively. Although rare, this fluid may produce life-threatening complications such as airway compromise. This article describes a case of upper airway obstruction in a 60-year-old man undergoing arthroscopic repair for an atrophic rotator cuff tear. The patient presented with a 6-month history of pain and weakness in the left shoulder. Magnetic resonance imaging studies revealed a massive rotator cuff tear with significant retraction and fatty degeneration of cuff musculature. Perioperatively, all vital cardiorespiratory parameters were within normal limits. Postoperatively, immediately on extubation, he was dyspneic, and examination revealed a diffuse swelling extending from the left shoulder up to the neck and face. He was reintubated and sent to the recovery room, where he recovered 12 hours later. This article highlights the possibility of respiratory compromise due to the extravasation of irrigation fluid into the neck and chest during arthroscopic repair of massive and atrophied cuff tears, even with shorter surgical time as is this case. The widened suprascapular space will offer less resistance to the spread of fluid into the neck and chest from the shoulder. We advocate monitoring the patient continuously to prevent this serious complication from becoming life-threatening.
Major complications of tibial tuberosity advancement in 1613 dogs.
Costa, Mario; Craig, Diane; Cambridge, Tony; Sebestyen, Peter; Su, Yuhua; Fahie, Maria A
2017-05-01
To report major postoperative complications in 1613 dogs with tibial tuberosity advancement (TTA). Retrospective case series. Dogs (n = 1613) with cranial cruciate ligament deficiency treated with TTA. Medical records of TTAs performed between December 2007-2013 were reviewed for age, sex, weight, contralateral stifle surgery, surgical approach, duration of preoperative lameness, presence of meniscal damage, concurrent patellar luxation and simultaneous bilateral TTA. Major postoperative complications were defined as surgical site infection (SSI) (superficial, deep, or organ/space), implant failure, fracture, patellar luxation, and meniscal tear. Major complications were recorded in 13.4% of cases. Superficial SSI (incisional irritation) was diagnosed in 6.9% cases, requiring only antimicrobial therapy. Other complications included postliminary medial meniscal tear (2% incidence), deep SSI (incisional dehiscence, 1.1%), implant failure (1%), patellar luxation (1.2%), fracture (0.9%), and organ/space SSI (septic arthritis, 0.4%). Dogs with normal menisci were less likely to develop postliminary meniscal tears if the medial meniscus was released at the time of TTA (P < .0001). No association was detected between recorded parameters and complications, although dogs >8 years old approached significance (P = .05) in terms of predisposition to major complications. Major complications after TTA are uncommon, even in dogs with concurrent patellar luxation or bilateral simultaneous procedures. In spite of its morbidity, medial meniscal release may prevent postliminary meniscal tears. © 2017 The American College of Veterinary Surgeons.
NASA Astrophysics Data System (ADS)
Punjabi, Alkesh; Ali, Halima; Evans, Todd
2006-10-01
In this work, the method of maps [1-4] is used to study the trajectories of magnetic field lines in the DIII-D tokamak. Data from the DIII-D shot 115467 is used to determine the parameters in the maps. Effects of the m=1, n=±1 tearing modes and the dipole perturbation from the C-coils on the motion of field lines are calculated. Internal tearing modes produce non-local effects on the magnetic footprints, and destroy their symmetry. Dipole perturbations mitigate the effects of the tearing modes, spread the heat-flux on the plates over a wider area, reduce the peak heat-flux, and reorganize the phase space structure in a new pattern that has the same symmetry as that of the external perturbation. The low dimensionality of the system and its symplecticity impose severe restrictions on the motion of the system in phase space forcing it to take on the symmetry properties of the perturbations. This work is done under the DOE grant number DE-FG02-01ER54624. 1. A. Punjabi, A. Boozer, and A. Verma, Phys. Rev. lett., 69, 3322 (1992). 2. H. Ali, A. Punjabi, and A. Boozer, Phys. Plasmas 11, 4527 (2004). 3. A. Punjabi, H. Ali, and A. Boozer, Phys. Plasmas 10, 3992 (2003). 4. A. Punjabi, H. Ali, and A. Boozer, Phys. Plasmas 4, 337 (1997).
[Research update of effectiveness and mechanism of essential fatty acids in treating dry eye].
Liu, Y; Liang, Q F
2017-03-11
Topical anti-inflammatory therapy has become the significant way of treating dry eye so far. However, as the long-term use of routine anti-inflammatory medications are restricted from their side effects, it is inevitable to explore safer and more effective alternatives. Essential fatty acids have proven to be anti-inflammatory systemically, which makes it possible to treat dry eye. Clinical trials have demonstrated that supplementation with either ω-3 or ω-6 essential fatty acids or both has multifactorial efficacies including improvement of subjective symptoms, alleviation of inflammation of ocular surface and eyelid margin, prolongation of tear break-up time and increase of tear flow secretion. Besides anti-inflammation effects, several basic researches have revealed that other mechanisms of essential fatty acids treating dry eye might lie in the corneal epithelial healing and tear secretion promotion. This review puts emphasis on the effectiveness, feasibility and mechanism of treating dry eye with essential fatty acids. (Chin J Ophthalmol, 2017, 53: 225-229) .
Wax-tear and meibum protein, wax–β-carotene interactions in vitro using infrared spectroscopy
Faheem, Samad; Kim, Sung-Hye; Nguyen, Jonathan; Neravetla, Shantanu; Ball, Matthew; Foulks, Gary N; Yappert, Marta C; Borchman, Douglas
2012-01-01
Protein–meibum and terpenoids–meibum lipid interactions could be important in the etiology of meibomian gland dysfunction (MGD) and dry eye symptoms. In the current model studies, attenuated total reflectance (ATR) infrared (IR) spectroscopy was used to determine if the terpenoid β-carotene and the major proteins in tears and meibum affect the hydrocarbon chain conformation and carbonyl environment of wax, an abundant component of meibum. The main finding of these studies is that mucin binding to wax disordered slightly the conformation of the hydrocarbon chains of wax and caused the wax carbonyls to become hydrogen bonded or experience a more hydrophilic environment. Lysozyme and lactoglobulin, two proteins shown to bind to monolayers of meibum, did not have such an effect. Keratin and β-carotene did not affect the fluidity (viscosity) or environment of the carbonyl moieties of wax. Based on these results, tetraterpenoids are not likely to influence the structure of meibum in the meibomian glands. In addition, these findings suggest that it is unlikely that keratin blocks meibomian glands by causing the meibum to become more viscous. Among the tear fluid proteins studied, mucin is the most likely to influence the conformation and carbonyl environment of meibum at the tear film surface. PMID:22564968
Use of a control test to aid pH assessment of chemical eye injuries.
Connor, A J; Severn, P
2009-11-01
Chemical burns of the eye represent 7.0%-9.9% of all ocular trauma. Initial management of ocular chemical injuries is irrigation of the eye and conjunctival sac until neutralisation of the tear surface pH is achieved.We present a case of alkali injury in which the raised tear film pH seemed to be unresponsive to irrigation treatment. Suspicion was raised about the accuracy of the litmus paper used to test the tear film pH. The error was confirmed by use of a control litmus pH test of the examining doctor's eyes. Errors in litmus paper pH measurement can occur because of difficulty in matching the paper with scale colours and drying of the paper, which produces a darker colour. A small tear film sample can also create difficulty in colour matching, whereas too large a sample can wash away pigment from the litmus paper. Samples measured too quickly after irrigation can result in a falsely neutral pH measurement. Use of faulty or inappropriate materials can also result in errors. We advocate the use of control litmus pH test in all patients. This would highlight errors in pH measurements and aid in the detection of the end point of irrigation.