Sample records for technetium-99m-tetrofosmin single photon

  1. Influence of proton-pump inhibitors on stomach wall uptake of 99mTc-tetrofosmin in cadmium-zinc-telluride SPECT myocardial perfusion imaging.

    PubMed

    Mouden, Mohamed; Rijkee, Karlijn S; Schreuder, Nanno; Timmer, Jorik R; Jager, Pieter L

    2015-02-01

    Proton-pump inhibitors (PPIs) induce potentially interfering stomach wall activity in single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI) with technetium-99m ((99m)Tc)-sestamibi. However, no data are available for (99m)Tc-tetrofosmin. We assessed the influence of prolonged (>2 weeks) PPI use on the stomach wall uptake of (99m)Tc-tetrofosmin in patients referred for stress MPI with a cadmium-zinc-telluride-based SPECT camera and its relation with dyspepsia symptoms. Consecutive patients (n=127) underwent a 1-day adenosine stress-first SPECT-MPI with (99m)Tc-tetrofosmin, of whom 54 (43%) patients had been on PPIs for more than 2 weeks. Stomach wall activity was identified on stress SPECT using computed tomographic attenuation maps and was scored using a four-point grading scale into clinically relevant (scores 2 or 3) or nonrelevant (scores 0 or 1).Patients on PPIs had stomach wall uptake more frequently as compared with patients not using PPIs (22 vs. 7%, P=0.017). Dyspepsia was similar in both groups. Prolonged use of PPIs is associated with stomach wall uptake of (99m)Tc-tetrofosmin in stress cadmium-zinc-telluride-SPECT images. Gastric symptoms were not associated with stomach wall uptake.

  2. Detecting Myocardial Ischemia With 99mTechnetium-Tetrofosmin Myocardial Perfusion Imaging in Ischemic Stroke.

    PubMed

    Giannopoulos, Sotirios; Markoula, Sofia; Sioka, Chrissa; Zouroudi, Sofia; Spiliotopoulou, Maria; Naka, Katerina K; Michalis, Lampros K; Fotopoulos, Andreas; Kyritsis, Athanassios P

    2017-10-01

    To assess the myocardial status in patients with stroke, employing myocardial perfusion imaging (MPI) with 99m Technetium-tetrofosmin ( 99m Tc-TF)-single-photon emission computed tomography (SPECT). Fifty-two patients with ischemic stroke were subjected to 99m Tc-TF-SPECT MPI within 1 month after stroke occurrence. None of the patients had any history or symptoms of coronary artery disease or other heart disease. Myocardial perfusion imaging was evaluated visually using a 17-segment polar map. Myocardial ischemia (MIS) was defined as present when the summed stress score (SSS) was >4; MIS was defined as mild when SSS was 4 to 8, and moderate/severe with SSS ≥9. Patients with SSS >4 were compared to patients with SSS <4. Parameters such as age, body mass index, waist perimeter, smoking habits, and medical history (diabetes mellitus, dyslipidemia, etc) were evaluated according to MPI results. Myocardial ischemia was present in 32 (62%) of 52 patients with stroke. Among them, 20 (62%) of 32 patients had mild abnormalities and 12 (38%) of 32 had moderate/severe. The age and waist perimeter showed a tendency to relate to severe MIS when patients with SSS >9 were compared to patients with SSS <4. In MPI-positive patients, an age was to be association with SSS, with the oldest age exhibiting the highest SSS ( P = .01). The association of age with SSS remained statistically significant in the multivariate analysis ( P = .04). The study suggested that more than half of patients with stroke without a history of cardiac disease have MIS. Although most of them have mild MIS, we suggest a thorough cardiological evaluation in this group of patients for future prevention of severe myocardial outcome.

  3. Technetium-99m tetrofosmin rest/stress myocardial SPET with a same-day 2-hour protocol: comparison with coronary angiography. A Spanish-Portuguese multicentre clinical trial.

    PubMed

    Montz, R; Perez-Castejón, M J; Jurado, J A; Martín-Comín, J; Esplugues, E; Salgado, L; Ventosa, A; Cantinho, G; Sá, E P; Fonseca, A T; Vieira, M R

    1996-06-01

    Technetium-99m tetrofosmin (Myoview) has unique properties for myocardial perfusion imaging very early after injection of the tracer. We used a very short same-day rest/stress protocol, to be performed within 2 h and evaluated its diagnostic accuracy. The study included 144 patients from seven Spanish and four Portuguese centres with a diagnosis of uncomplicated coronary artery disease (CAD); 78 patients (54%) had no history of prior myocardial infarction. Patients were injected with 99mTc-tetrofosmin at rest and Single-photon emission tomographic (SPET) acquisitions were initiated within 5-30 min post injection. The results were compared with those of coronary angiography (CA). The data of 142 patients were completely evaluable (two with non-evaluable images were excluded). The quality of rest images was excellent or good in 86%, regionally problematic in 7%, poor but well interpretable in 5% and non-evaluable in 2%. The overall sensitivity for the detection of CAD was 93%, the specificity 38% and the accuracy 85%. The localization of defects by SPET in relation to the perfusion territories of stenosed vessels (>/=50%) was achieved with a sensitivity of 64% for the left anterior descending artery, 49% for the left circumflex artery and 86% for the right coronary artery, and an accuracy of 71%, 72% and 73% respectively. Concordance of SPET and CA was 62% for single-vessel disease and 68% for multivessel disease. In conclusion, this Spanish-Portuguese multicentre clinical trial confirmed, in a considerable number of patients who underwent coronary angiography, the feasibility of 99mTc tetrofosmin (Myoview) rest/stress myocardial SPET using a very short protocol (2 h).

  4. Myocardial impairment detected by late gadolinium enhancement in hypertrophic cardiomyopathy: comparison with 99mTc-MIBI/tetrofosmin and 123I-BMIPP SPECT.

    PubMed

    Hashimura, Hiromi; Kiso, Keisuke; Yamada, Naoaki; Kono, Atsushi; Morita, Yoshiaki; Fukushima, Kazuto; Higashi, Masahiro; Noguchi, Teruo; Ishibashi-Ueda, Hatsue; Naito, Hiroaki; Sugimura, Kazuro

    2013-06-17

    Myocardial fibrosis is considered to be an important factor in myocardial dysfunction and sudden cardiac death in hypertrophic cardiomyopathy (HCM). The purpose of this study was to compare myocardial fibrosis detected by late gadolinium enhancement (LGE) on cardiac MRI with myocardial perfusion and fatty acid metabolism assessed by single photon emission computed tomography in HCM. We retrospectively evaluated 20 consecutive HCM patients (female, 7; mean age, 53.4 years) who underwent LGE, technetium-99m methoxyisobutylisonitrile/tetrofosmin (99mTc-MIBI/tetrofosmin), and iodine-123 beta-methyl-iodophenylpentadecanoic acid (123I-BMIPP) imaging. We calculated the myocardium-to-lumen signal ratio (M/L) for LGE in 17 segments based on the American Heart Association statement. Scoring of 99mTc-MIBI/tetrofosmin (PI) and 123I-BMIPP (BM) was performed for each segment using a 5-point scale (0, normal; 4, highly decreased). Nineteen of 20 patients (95%) and 153 of 340 segments (45%) showed LGE. M/Ls were 0.42±0.16, 0.55±0.17, and 0.65±0.24 in PI0/BM0, PI0/BM1-4 and PI1-4/BM1-4, respectively. All M/Ls were significantly higher than that of a normal control (0.34±0.14) (p<0.001). Myocardial fibrosis in HCM can occur despite normal perfusion and fatty acid metabolism, and is more strongly associated with disorders of fatty acid metabolism than with perfusion abnormalities. M/L may be a useful indicator of disease severity.

  5. The use of technetium-99m-labeled human serum albumin diethylenetriamine pentaacetic acid single-photon emission CT scan in the follow-up of type II endoleak treatment.

    PubMed

    Nakai, Motoki; Sato, Hirotatsu; Ikoma, Akira; Sonomura, Tetsuo; Sato, Morio

    2014-03-01

    An 84-year-old woman presented with persistent type II endoleak with sac expansion from 57 mm to 75 mm during 4-year follow-up after endovascular abdominal aortic aneurysm repair. The patient underwent transabdominal embolization with coils and N-butyl cyanoacrylate/ethiodized oil (Lipiodol; Guerbet, Villepinte, France) mixture (2.5 mL). Because of the anticipated embolization artifacts on follow-up computed tomography (CT), technetium-99m-labeled human serum albumin diethylenetriamine pentaacetic acid single-photon emission computed tomography ((99m)Tc-HSAD SPECT) was performed before and after the intervention. Perigraft accumulation on (99m)Tc-HSAD SPECT corresponding to the endoleak disappeared after embolization. CT scan performed 12 months after embolization showed no signs of sac expansion. (99m)Tc-HSAD SPECT may be useful for evaluating therapeutic effect after embolization for endoleak. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  6. Technetium-99m: basic nuclear physics and chemical properties.

    PubMed

    Castronovo, F P

    1975-05-01

    The nuclear physics and chemical properties of technetium-99m are reviewed. The review of basic nuclear physics includes: classification of nuclides, nuclear stability, production of radionuclides, artificial production of molybdenum-99, production of technetium 99m and -99Mo-99mTc generators. The discussion of the chemistry of technetium includes a profile of several -99mCc-labeled radiopharmaceuticals.

  7. Measurement of absolute myocardial blood flow in humans using dynamic cardiac SPECT and 99mTc-tetrofosmin: Method and validation

    DOE PAGES

    Shrestha, Uttam; Sciammarella, Maria; Alhassen, Fares; ...

    2015-12-29

    The objective of this study was to measure myocardial blood flow (MBF) in humans using 99mTc-tetrofosmin and dynamic single-photon emission computed tomography (SPECT). Dynamic SPECT using 99mTc-tetrofosmin and dynamic positron emission tomography (PET) was performed on a group of 16 patients. The SPECT data were reconstructed using a 4D-spatiotemporal iterative reconstruction method. The data corresponding to 9 patients were used to determine the flow-extraction curve for 99mTc-tefrofosmin while data from the remaining 7 patients were used for method validation. The nonlinear tracer correction parameters A and B for 99mTc-tefrofosmin were estimated for the 9 patients by fitting the flow-extraction curvemore » K 1 = F(1–Aexp(–B/F)) for K 1 values estimated with 99mTc-tefrofosmin using SPECT and MBF values estimated with 13N-NH 3 using PET. These parameters were then used to calculate MBF and coronary flow reserve (CFR) in three coronary territories (LAD, RCA, and LCX) using SPECT for an independent cohort of 7 patients. The results were then compared with that estimated with 13N-NH 3 PET. The flow-dependent permeability surface-area product (PS) for 99mTc-tefrofosmin was also estimated. The estimated flow-extraction parameters for 99mTc-tefrofosmin were found to be A = 0.91 ± 0.11, B = 0.34 ± 0.20 (R 2 = 0.49). The range of MBF in LAD, RCA, and LCX was 0.44-3.81 mL/min/g. The MBF between PET and SPECT in the group of independent cohort of 7 patients showed statistically significant correlation, r = 0.71 (P < .001). However, the corresponding CFR correlation was moderate r = 0.39 yet statistically significant (P = .037). The PS for 99mTc-tefrofosmin was (0.019 ± 0.10)*MBF + (0.32 ± 0.16). Dynamic cardiac SPECT using 99mTc-tetrofosmin and a clinical two-headed SPECT/CT scanner can be a useful tool for estimation of MBF.« less

  8. Measurement of absolute myocardial blood flow in humans using dynamic cardiac SPECT and 99mTc-tetrofosmin: Method and validation.

    PubMed

    Shrestha, Uttam; Sciammarella, Maria; Alhassen, Fares; Yeghiazarians, Yerem; Ellin, Justin; Verdin, Emily; Boyle, Andrew; Seo, Youngho; Botvinick, Elias H; Gullberg, Grant T

    2017-02-01

    The objective of this study was to measure myocardial blood flow (MBF) in humans using 99m Tc-tetrofosmin and dynamic single-photon emission computed tomography (SPECT). Dynamic SPECT using 99m Tc-tetrofosmin and dynamic positron emission tomography (PET) was performed on a group of 16 patients. The SPECT data were reconstructed using a 4D-spatiotemporal iterative reconstruction method. The data corresponding to 9 patients were used to determine the flow-extraction curve for 99m Tc-tefrofosmin while data from the remaining 7 patients were used for method validation. The nonlinear tracer correction parameters A and B for 99m Tc-tefrofosmin were estimated for the 9 patients by fitting the flow-extraction curve [Formula: see text] for K 1 values estimated with 99m Tc-tefrofosmin using SPECT and MBF values estimated with 13 N-NH 3 using PET. These parameters were then used to calculate MBF and coronary flow reserve (CFR) in three coronary territories (LAD, RCA, and LCX) using SPECT for an independent cohort of 7 patients. The results were then compared with that estimated with 13 N-NH 3 PET. The flow-dependent permeability surface-area product (PS) for 99m Tc-tefrofosmin was also estimated. The estimated flow-extraction parameters for 99m Tc-tefrofosmin were found to be A = 0.91 ± 0.11, B = 0.34 ± 0.20 (R 2  = 0.49). The range of MBF in LAD, RCA, and LCX was 0.44-3.81 mL/min/g. The MBF between PET and SPECT in the group of independent cohort of 7 patients showed statistically significant correlation, r = 0.71 (P < .001). However, the corresponding CFR correlation was moderate r = 0.39 yet statistically significant (P = .037). The PS for 99m Tc-tefrofosmin was (0.019 ± 0.10)*MBF + (0.32 ± 0.16). Dynamic cardiac SPECT using 99m Tc-tetrofosmin and a clinical two-headed SPECT/CT scanner can be a useful tool for estimation of MBF.

  9. Measurement of absolute myocardial blood flow in humans using dynamic cardiac SPECT and 99mTc-tetrofosmin: Method and validation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shrestha, Uttam; Sciammarella, Maria; Alhassen, Fares

    The objective of this study was to measure myocardial blood flow (MBF) in humans using 99mTc-tetrofosmin and dynamic single-photon emission computed tomography (SPECT). Dynamic SPECT using 99mTc-tetrofosmin and dynamic positron emission tomography (PET) was performed on a group of 16 patients. The SPECT data were reconstructed using a 4D-spatiotemporal iterative reconstruction method. The data corresponding to 9 patients were used to determine the flow-extraction curve for 99mTc-tefrofosmin while data from the remaining 7 patients were used for method validation. The nonlinear tracer correction parameters A and B for 99mTc-tefrofosmin were estimated for the 9 patients by fitting the flow-extraction curvemore » K 1 = F(1–Aexp(–B/F)) for K 1 values estimated with 99mTc-tefrofosmin using SPECT and MBF values estimated with 13N-NH 3 using PET. These parameters were then used to calculate MBF and coronary flow reserve (CFR) in three coronary territories (LAD, RCA, and LCX) using SPECT for an independent cohort of 7 patients. The results were then compared with that estimated with 13N-NH 3 PET. The flow-dependent permeability surface-area product (PS) for 99mTc-tefrofosmin was also estimated. The estimated flow-extraction parameters for 99mTc-tefrofosmin were found to be A = 0.91 ± 0.11, B = 0.34 ± 0.20 (R 2 = 0.49). The range of MBF in LAD, RCA, and LCX was 0.44-3.81 mL/min/g. The MBF between PET and SPECT in the group of independent cohort of 7 patients showed statistically significant correlation, r = 0.71 (P < .001). However, the corresponding CFR correlation was moderate r = 0.39 yet statistically significant (P = .037). The PS for 99mTc-tefrofosmin was (0.019 ± 0.10)*MBF + (0.32 ± 0.16). Dynamic cardiac SPECT using 99mTc-tetrofosmin and a clinical two-headed SPECT/CT scanner can be a useful tool for estimation of MBF.« less

  10. Measurement of Absolute Myocardial Blood Flow in Humans Using Dynamic Cardiac SPECT and 99mTc-tetrofosmin: Method and Validation

    PubMed Central

    Shrestha, Uttam; Sciammarella, Maria; Alhassen, Fares; Yeghiazarians, Yerem; Ellin, Justin; Verdin, Emily; Boyle, Andrew; Seo, Youngho; Botvinick, Elias H.; Gullberg, Grant T.

    2015-01-01

    Background The objective of this study was to measure myocardial blood flow (MBF) in humans using 99mTc-tetrofosmin and dynamic single photon emission computed tomography (SPECT). Methods Dynamic SPECT using 99mTc-tetrofosmin and dynamic positron emission tomography (PET) was performed on a group of 16 patients. The SPECT data were reconstructed using a 4D-spatiotemporal iterative reconstruction method. The data corresponding to 9 patients were used to determine the flow-extraction curve for 99mTc-tefrofosmin while data from the remaining 7 patients were used for method validation. The nonlinear tracer correction parameters A and B for 99mTc-tefrofosmin were estimated for the 9 patients by fitting the flow-extraction curve K1=F(1−Aexp(−BF)) for K1 values estimated with 99mTc-tefrofosmin using SPECT and MBF values estimated with 13N-NH3 using PET. These parameters were then used to calculate MBF and coronary flow reserve (CFR) in three coronary territories (LAD, RCA, and LCX) using SPECT for an independent cohort of 7 patients. The results were then compared with that estimated with 13N-NH3 PET. The flow dependent permeability surface-area product (PS) for 99mTc-tefrofosmin was also estimated. Results The estimated flow extraction parameters for 99mTc-tefrofosmin was found to be A=0.91±0.11, B=0.34±0.20 (R2 = 0.49). The range of MBF in LAD, RCA, and LCX was 0.44 ml/min/g to 3.81 ml/min/g. The MBF between PET and SPECT in the group of independent cohort of 7 patients showed statistically significant correlation, r = 0.71 (p < 0.001). However, the corresponding CFR correlation was moderate r = 0.39 yet statistically significant (p = 0.037). The PS for 99mTc-tefrofosmin was (0.091 ± 0.10) * MBF = (0.32 ± 0.16). Conclusions Dynamic cardiac SPECT using 99mTc-tetrofosmin and a clinical two-headed SPECT/CT scanner can be a useful tool for estimation of MBF. PMID:26715603

  11. Transglutaminase-mediated conjugation and nitride-technetium-99m labelling of a bis(thiosemicarbazone) bifunctional chelator.

    PubMed

    Salvarese, Nicola; Spolaore, Barbara; Marangoni, Selena; Pasin, Anna; Galenda, Alessandro; Tamburini, Sergio; Cicoria, Gianfranco; Refosco, Fiorenzo; Bolzati, Cristina

    2018-06-01

    An assessment study involving the use of the transglutaminase (TGase) conjugation method and the nitride-technetium-99m labelling on a bis(thiosemicarbazone) (BTS) bifunctional chelating agent is presented. The previously described chelator diacetyl-2-(N 4 -methyl-3-thiosemicarbazone)-3-(N 4 -amino-3-thiosemicarbazone), H 2 ATSM/A, has been functionalized with 6-aminohexanoic acid (ε-Ahx) to generate the bifunctional chelating agent diacetyl-2-(N 4 -methyl-3-thiosemicarbazone)-3-[N 4 -(amino)-(6-aminohexanoic acid)-3-thiosemicarbazone], H 2 ATSM/A-ε-Ahx (1), suitable for conjugation to glutamine (Gln) residues of bioactive molecules via TGase. The feasibility of the TGase reaction in the synthesis of a bioconjugate derivative was investigated using Substance P (SP) as model peptide. Compounds 1 and H 2 ATSM/A-ε-Ahx-SP (2) were labelled with nitride-technetium-99m, obtaining the complexes [ 99m Tc][Tc(N)(ATSM/A-ε-Ahx)] ( 99m Tc1) and [ 99m Tc][Tc(N)(ATSM/A-ε-Ahx-SP)] ( 99m Tc2). The chemical identity of 99m Tc1 and 99m Tc2 was confirmed by radio/UV-RP-HPLC combined with ESI-MS analysis on the respective carrier-added products 99g/99m Tc1 and 99g/99m Tc2. The stability of the radiolabelled complexes after incubation in various environments was investigated. All the results were compared with those obtained for the corresponding 64 Cu-analogues, 64 Cu1 and 64 Cu2. The TGase reaction allows the conjugation of 1 with the peptide, but it is not highly efficient due to instability of the chelator in the required conditions. The SP-conjugated complexes are unstable in mouse and human sera. However, indeed the BTS system can be exploited as nitride-technetium-99m chelator for highly efficient technetium labelling, thus making compound 1 worthy of further investigations for new targeted technetium and copper radiopharmaceuticals encompassing Single Photon Emission Computed Tomography and Positron Emission Tomography imaging. Copyright © 2018 Elsevier Inc. All rights

  12. Randomized, single-blind, factorial design study of the interaction of food and time on intestinal activity in 99mTc-tetrofosmin stress myocardial perfusion scintigraphy.

    PubMed

    Lyngholm, Ann Marie; Pedersen, Begitte H; Petersen, Lars J

    2008-09-01

    Intestinal activity at the inferior myocardial wall represents an issue for assessment of myocardial perfusion imaging (MPI) with 99mTc-labelled tracers. The aim of this study was to investigate the effect of time and food on upper abdominal activity in 99mTc-tetrofosmin MPI. The study population consisted of 152 consecutive patients referred for routine MPI. All patients underwent 2-day stress-rest 99mTc-tetrofosmin single-photon emission computed tomography MPI. Before stress testing, patients were randomized in a factorial design to four different regimens. Group A: early scan (image acquisition initiated within 15 min after injection of the tracer) and no food; group B: early scan and food (two pieces of white bread with butter and a minimum of 450 ml of water); group C: late scan (image acquisition 30-60 min after injection of the tracer) and no food; and group D: late and scan with food. Patients underwent standard bicycle exercise or pharmacological stress test. The degree of upper abdominal activity was evaluated by trained observers blinded to the randomization code. The primary endpoint was the proportion of accepted scans in the intention-to-treat population in stress MPI. The results showed statistical significant impact on both time and food on upper abdominal activity. The primary endpoint showed that the acceptance rate improved from 55% in group A to 100% success rate in group D. An early scan reduced the acceptance rate by 30% versus a late scan [hazard ratio 0.70, 95% confidence interval 0.58-0.84; P<0.0001], whereas the addition of food improved the success rate versus no food by 27% (hazard ratio 1.27, 95% confidence interval 1.07-1.51; P=0.006). No significant interaction between food and time was observed. An analysis of accepted scans according to the actual scan time and food consumption confirmed the findings of the intention-to-treat analysis. In addition, similar findings were seen in 116 of 152 patients with a rest MPI (success rate of

  13. Cortical perfusion response to an electrical stimulation of the auditory nerve in profoundly deaf patients: study with technetium-99m hexamethylpropylene amine oxime single photon emission tomography.

    PubMed

    Le Scao, Y; Robier, A; Baulieu, J L; Beutter, P; Pourcelot, L

    1992-01-01

    Brain activation procedures associated with single photon emission tomography (SPET) have recently been developed in healthy controls and diseased patients in order to help in their diagnosis and treatment. We investigated the effects of a promontory test (PT) on the cerebral distribution of technetium-99m hexamethylpropylene amine oxime (99mTc-HMPAO) in 7 profoundly deaf patients, 6 PT+ and one PT-. The count variation in the temporal lobe was calculated on 6 coronal slices using the ratio (Rstimulation-Rdeprivation)/Rdeprivation where R = counts in the temporal lobe/whole-brain count. A count increase in the temporal lobe was observed in all patients and was higher in all patients with PT+ than in the patient with PT-. The problems of head positioning and resolution of the system were taken into account, and we considered that the maximal count increment was related to the auditory cortex response to the stimulus. Further clinical investigations with high-resolution systems have to be performed in order to validate this presurgery test in cochlear implant assessment.

  14. Magnetic core mesoporous silica nanoparticles doped with dacarbazine and labelled with 99mTc for early and differential detection of metastatic melanoma by single photon emission computed tomography.

    PubMed

    Portilho, Filipe Leal; Helal-Neto, Edward; Cabezas, Santiago Sánchez; Pinto, Suyene Rocha; Dos Santos, Sofia Nascimento; Pozzo, Lorena; Sancenón, Félix; Martínez-Máñez, Ramón; Santos-Oliveira, Ralph

    2018-02-27

    Cancer is responsible for more than 12% of all causes of death in the world, with an annual death rate of more than 7 million people. In this scenario melanoma is one of the most aggressive ones with serious limitation in early detection and therapy. In this direction we developed, characterized and tested in vivo a new drug delivery system based on magnetic core-mesoporous silica nanoparticle that has been doped with dacarbazine and labelled with technetium 99 m to be used as nano-imaging agent (nanoradiopharmaceutical) for early and differential diagnosis and melanoma by single photon emission computed tomography. The results demonstrated the ability of the magnetic core-mesoporous silica to be efficiently (>98%) doped with dacarbazine and also efficiently labelled with 99mTc (technetium 99 m) (>99%). The in vivo test, using inducted mice with melanoma, demonstrated the EPR effect of the magnetic core-mesoporous silica nanoparticles doped with dacarbazine and labelled with technetium 99 metastable when injected intratumorally and the possibility to be used as systemic injection too. In both cases, magnetic core-mesoporous silica nanoparticles doped with dacarbazine and labelled with technetium 99 metastable showed to be a reliable and efficient nano-imaging agent for melanoma.

  15. 99M-Technetium labeled tin colloid radiopharmaceuticals

    DOEpatents

    Winchell, Harry S.; Barak, Morton; Van Fleet, III, Parmer

    1976-07-06

    An improved 99m-technetium labeled tin(II) colloid, size-stabilized for reticuloendothelial organ imaging without the use of macromolecular stabilizers and a packaged tin base reagent and an improved method for making it are disclosed.

  16. Radionuclide Basics: Technetium-99

    EPA Pesticide Factsheets

    Technetium-99 (chemical symbol Tc-99) is a silver-gray, radioactive metal. It occurs naturally in very small amounts in the earth's crust, but is primarily man-made. Technetium-99m is a short-lived form of Tc-99 that is used as a medical diagnostic tool.

  17. Enhanced washout of 99mTc-tetrofosmin in hypertrophic cardiomyopathy: quantitative comparisons with regional 123I-BMIPP uptake and wall thickness determined by MRI.

    PubMed

    Thet-Thet-Lwin; Takeda, Tohoru; Wu, Jin; Fumikura, Yuko; Iida, Keiji; Kawano, Satoru; Yamaguchi, Iwao; Itai, Yuji

    2003-07-01

    The diagnostic value of technetium-99m tetrofosmin (TF) washout in hypertrophic cardiomyopathy (HCM) was examined by investigating its relation to the metabolic abnormality depicted by iodine-123 beta-methyl- p-iodophenylpentadecanoic acid (BMIPP) uptake and the left ventricular (LV) myocardial wall thickness as measured by magnetic resonance imaging (MRI). TF washout was evaluated in 31 patients with HCM and 23 normal control subjects using 30-min (early) and 3-h (delayed) TF single-photon emission tomography images. The LV myocardial wall was divided into 19 segments and the percentage TF washout, regional BMIPP uptake and LV wall thickness were measured in each segment. Mean TF washout in the patients with HCM was significantly faster than that in normal control subjects (23.7+/-5.7 vs 13.4+/-4.1, P<0.0001). In the patients with HCM, TF washout showed an excellent correlation with MRI wall thickness ( r=0.82, P<0.0001) and a good inverse correlation with regional BMIPP uptake ( r=-0.72, P<0.0001). In addition, a good linear correlation was observed between TF uptake and MRI wall thickness in the 19 regional segments. In conclusion, the degree of TF washout corresponds well with the severity of myocardial wall thickness and the degree of metabolic abnormality in patients with HCM. These results suggest that enhanced TF washout might provide additional clinical information regarding metabolic alterations in HCM.

  18. 18F-Fluorocholine PET/CT in the assessment of primary hyperparathyroidism compared with 99mTc-MIBI or 99mTc-tetrofosmin SPECT/CT: a prospective dual-centre study in 100 patients.

    PubMed

    Beheshti, Mohsen; Hehenwarter, Lukas; Paymani, Zeinab; Rendl, Gundula; Imamovic, Larisa; Rettenbacher, Rupert; Tsybrovskyy, Oleksiy; Langsteger, Werner; Pirich, Christian

    2018-03-08

    In this prospective study we compared the accuracy of 18 F-fluorocholine PET/CT with that of 99m Tc-MIBI or 99m Tc-tetrofosmin SPECT/CT in the preoperative detection of parathyroid adenoma in patients with primary hyperparathyroidism. We also assessed the value of semiquantitative parameters in differentiating between parathyroid hyperplasia and adenoma. Both 18 F-fluorocholine PET/CT and 99m Tc-MIBI/tetrofosmin SPECT/CT were performed in 100 consecutive patients with biochemical evidence of primary hyperparathyroidism. At least one abnormal focus on either 18 F-fluorocholine or 99m Tc-MIBI/tetrofosmin corresponding to a parathyroid gland or ectopic parathyroid tissue was considered as a positive finding. In 76 patients with positive findings on at least one imaging modality, surgical exploration was performed within 6 months, and the results were related to histopathological findings and clinical and laboratory findings at 3-6 months as the standard of truth. In 24 patients, no surgery was performed: in 18 patients with positive imaging findings surgery was refused or considered risky, and in 6 patients imaging was negative. Therefore, data from 82 patients (76 undergoing surgery, 6 without surgery) in whom the standard of truth criteria were met, were used in the final analysis. All patients showed biochemical evidence of primary hyperparathyroidism with a mean serum calcium level of 2.78 ± 0.34 mmol/l and parathormone (PTH) level of 196.5 ± 236.4 pg/ml. The study results in 76 patients with verified histopathology and 3 patients with negative imaging findings were analysed. Three of six patients with negative imaging showed normalized serum PTH and calcium levels on laboratory follow-up at 3 and 6 months, and the results were considered true negative. In a patient-based analysis, the detection rate with 18 F-fluorocholine PET/CT was 93% (76/82), but was only 61% (50/82) with 99m Tc-MIBI/tetrofosmin SPECT/CT. In a lesion-based analysis, the

  19. The value and throughput of rest Thallium-201/stress Technetium -99m sestamibi dual-isotope myocardial SPECT.

    PubMed

    Okudan, Berna; Smitherman, Thomas C

    2004-06-01

    Myocardial perfusion scintigraphy is an established method in cardiology for the diagnosis and evaluation of coronary artery disease (CAD). Thallium-201 and Tc-99m sestamibi myocardial perfusion imaging has been widely accepted as non-invasive diagnostic procedure for detection of CAD, risk stratification and myocardial viability assessment. But, standard Tl-201 redistribution and same day or 2-day rest/stress Tc-99m sestamibi protocols are time-consuming. Hence, the dual isotope rest thallium-201/stress technetium-99m sestamibi gated single-photon emission tomography protocol has gained increasing popularity for these applications. Combining the use of thallium-201 with technetium-99m agents permits optimal image resolution and simultaneous assessment of viability. Dual-isotope imaging may be separate or simultaneous acquisition set-up. The more rapid completion of these studies is appreciated as an advantage by patients, technologists, interpreting and referring physicians, nurses and hospital management. Simultaneous imaging has the potential advantages of precise pixel registration and artifacts, if present, are identical in both thallium and sestamibi, and require only one set of imaging. Also, there are some disadvantages of spillover of activity from the Tc-99m to the Tl-201 window. Fortunately, despite this problem it can be overcome. Separate acquisition dual isotope also has some disadvantages. Difference in defect resolution in attenuation and scatter between T-201 and Tc-99m sestamibi potentially results in interpretation problems. But, studies about cost-effectiveness of dual isotope imaging showed that some selective elimination of the rest studies may decrease the cost of the nuclear procedures and should be considered in the current care health system.

  20. Liver Function Assessment Using Technetium 99m-Galactosyl Single-Photon Emission Computed Tomography/CT Fusion Imaging: A Prospective Trial.

    PubMed

    Okabayashi, Takehiro; Shima, Yasuo; Morita, Sojiro; Shimada, Yasuhiro; Sumiyoshi, Tatsuaki; Sui, Kenta; Iwata, Jun; Iiyama, Tatsuo

    2017-12-01

    The prediction of postoperative liver function remains a largely subjective practice based on CT volumetric analysis. However, future liver volume after a hepatectomy is not the only factor that contributes to postoperative liver function and outcomes. In this prospective trial, 185 consecutive patients who underwent liver operations between 2014 and 2015 were studied. Volumetric and functional rates of remnant liver were measured using technetium 99m-galactosyl human serum albumin single-photon emission computed tomography/CT fusion imaging to evaluate post-hepatectomy remnant liver function. Remnant indocyanine green clearance rate using galactosyl (KGSA) (KGSA × functional rate) was used to predict future remnant liver function. Hepatectomy was considered safe for patients with remnant KGSA values ≥0.05, and the primary end point was to determine the accuracy and reliability of this criteria. The prediction of the 90-day major complication and mortality rates was assessed. Median hospital stay was 9 days and median ICU stay was 1 day, with only 1 in-hospital death (90-day mortality rate 0.5%). Overall morbidity rate evaluated according to the Clavien-Dindo classification was 9%. For post-hepatectomy liver failure definitions, the International Study Group of Liver Surgery definition was fulfilled in 14 patients (8%), with the majority being grade B (50%), compared with 2 patients (1%) fulfilling the "50-50" criteria, and 0 patients (0%) fulfilling the Peak Bili >7 criteria. Results of this study showed that remnant KGSA provided information that allowed us to predict remnant liver function. This information will be important for surgeons when deciding on a treatment plan for patients with liver diseases. (ClinicalTrials.gov ID: NCT02013895). Copyright © 2017 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  1. Evolution of technetium-99m-HMPAO SPECT and brain mapping in a patient presenting with echolalia and palilalia.

    PubMed

    Dierckx, R A; Saerens, J; De Deyn, P P; Verslegers, W; Marien, P; Vandevivere, J

    1991-08-01

    A 78-yr-old woman presented with transient echolalia and palilalia. She had suffered from Parkinson's disease for 2 yr. Routine laboratory examination showed hypotonic hyponatremia, but was otherwise unremarkable. Brain mapping revealed a bifrontal delta focus, more pronounced on the right. Single photon emission computed tomography (SPECT) of the brain with technetium-99m labeled d,l hexamethylpropylene-amine oxime (99mTc-HMPAO), performed during the acute episode showed relative frontoparietal hypoactivity. Brain mapping performed after disappearance of the echolalia and palilalia, which persisted only for 1 day, was normal. By contrast, SPECT findings persisted for more than 3 wk. Features of particular interest in the presented patient are the extensive defects seen on brain SPECT despite the absence of morphologic lesions, the congruent electrophysiologic changes and their temporal relationship with the clinical evolution.

  2. Effects of concurrent drug therapy on technetium /sup 99m/Tc gluceptate biodistribution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hinkle, G.H.; Basmadjian, G.P.; Peek, C.

    Drug interactions with /sup 99m/Tc gluceptate resulting in altered biodistribution were studied using chart review and animal tests. Charts of nine patients who had abnormal gallbladder uptake of technetium /sup 99m/Tc gluceptate during a two-year period were reviewed to obtain data such as concurrent drug therapy, primary diagnosis, and laboratory values. Adult New Zealand white rabbits were then used for testing the biodistribution of technetium /sup 99m/Tc gluceptate when administered concurrently with possibly interacting drugs identified in the chart review--penicillamine, penicillin G potassium, penicillin V potassium, acetaminophen, and trimethoprim-sulfamethoxazole. Chart review revealed no conclusive patterns of altered biodistribution associated withmore » other factors. The data did suggest the possibility that the five drugs listed above might cause increased hepatobiliary clearance of the radiopharmaceutical. Animal tests showed that i.v. penicillamine caused substantial distribution of radioactivity into the gallbladder and small bowel. Minimally increased gallbladder radioactivity occurred when oral acetaminophen and trimethoprim-sulfamethoxazole were administered concurrently. Oral and i.v. penicillins did not increase gallbladder activity. Penicillamine may cause substantial alteration of the biodistribution of technetium /sup 99m/Tc gluceptate.« less

  3. Quantitative single-photon emission computed tomography/computed tomography for technetium pertechnetate thyroid uptake measurement

    PubMed Central

    Lee, Hyunjong; Kim, Ji Hyun; Kang, Yeon-koo; Moon, Jae Hoon; So, Young; Lee, Won Woo

    2016-01-01

    Abstract Objectives: Technetium pertechnetate (99mTcO4) is a radioactive tracer used to assess thyroid function by thyroid uptake system (TUS). However, the TUS often fails to deliver accurate measurements of the percent of thyroid uptake (%thyroid uptake) of 99mTcO4. Here, we investigated the usefulness of quantitative single-photon emission computed tomography/computed tomography (SPECT/CT) after injection of 99mTcO4 in detecting thyroid function abnormalities. Materials and methods: We retrospectively reviewed data from 50 patients (male:female = 15:35; age, 46.2 ± 16.3 years; 17 Graves disease, 13 thyroiditis, and 20 euthyroid). All patients underwent 99mTcO4 quantitative SPECT/CT (185 MBq = 5 mCi), which yielded %thyroid uptake and standardized uptake value (SUV). Twenty-one (10 Graves disease and 11 thyroiditis) of the 50 patients also underwent conventional %thyroid uptake measurements using a TUS. Results: Quantitative SPECT/CT parameters (%thyroid uptake, SUVmean, and SUVmax) were the highest in Graves disease, second highest in euthyroid, and lowest in thyroiditis (P < 0.0001, Kruskal–Wallis test). TUS significantly overestimated the %thyroid uptake compared with SPECT/CT (P < 0.0001, paired t test) because other 99mTcO4 sources in addition to thyroid, such as salivary glands and saliva, contributed to the %thyroid uptake result by TUS, whereas %thyroid uptake, SUVmean and SUVmax from the SPECT/CT were associated with the functional status of thyroid. Conclusions: Quantitative SPECT/CT is more accurate than conventional TUS for measuring 99mTcO4 %thyroid uptake. Quantitative measurements using SPECT/CT may facilitate more accurate assessment of thyroid tracer uptake. PMID:27399139

  4. [Situation of supply and boom of PET imaging: what is the future for technetium-99m in nuclear medicine?].

    PubMed

    Maia, S; Ayachi Hatit, N; Paycha, F

    2011-05-01

    Molecular imaging has shown its interest in the diagnosis, staging and therapy monitoring of many diseases, especially in the field of cancer. This imaging modality can detect non-invasively early molecular changes specific to these diseases. Its expansion includes two aspects linked firstly with the advanced techniques of imaging modalities and secondly with the development of tracers as radio pharmaceuticals for imaging new molecular targets. Technetium-99m ((99m)Tc), because of its physical characteristics, its widespread availability and low cost, is the most used radionuclide in molecular imaging with the technique of single photon emission computed tomography (SPECT). Nevertheless, the current difficulty concerning the supply and the great interest of Positron Emission Tomography (PET), the "competitor" imaging modality-using molecules labelled with fluorine-18 ((18)F), legitimates the question about the future of (99m)Tc, its supremacy and the emergence of new tracer labelled with (99m)Tc. Focusing on the actual and future supply situation, the place of SPECT imaging in nuclear medicine, as well as the development of new molecules labelled with (99m)Tc is necessary to show that this radionuclide will remain essential for the speciality in the next years. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  5. Accelerator Generation and Thermal Separation (AGATS) of Technetium-99m

    ScienceCinema

    Grover, Blaine

    2018-05-01

    Accelerator Generation and Thermal Separation (AGATS) of Technetium-99m is a linear electron accelerator-based technology for producing medical imaging radioisotopes from a separation process that heats, vaporizes and condenses the desired radioisotope. You can learn more about INL's education programs at http://www.facebook.com/idahonationallaboratory.

  6. Soft-tissue sarcoma: imaged with technetium-99m pyrophosphate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blatt, C.J.; Hayt, D.B.; Desai, M.

    1977-11-01

    A liposarcoma showed intense concentration of technetium-99m pyrophosphate. An angiogram demonstrated a highly vascular lesion, and it is suggested that blood flow played a major role in allowing the tumor to be demonstrated on scintiphotography. There was some histologic evidence of calcification which probably also contributed to bone-tracer disposition. Quantitative analysis of the specimen demonstrated that this calcification was located primarily in the areas of hemorrhage and necrosis.

  7. Hyperthermia increases accumulation of technetium-99m-labeled liposomes in feline sarcomas.

    PubMed

    Matteucci, M L; Anyarambhatla, G; Rosner, G; Azuma, C; Fisher, P E; Dewhirst, M W; Needham, D; Thrall, D E

    2000-09-01

    The effect of hyperthermia on the accumulation of technetium-99m-labeled liposomes was studied in feline sarcomas. Each cat received two separate injections of liposomes. The first was used to quantify the amount of technetium-99m-labeled liposomes within the tumor under normothermic conditions. The second injection was made at the beginning of a 60-min hyperthermia procedure. Planar scintigraphy was used to measure the activity of technetium-99m-labeled liposomes within the tumor at predetermined times up to 18 h after injection. Regions of interest were drawn for the tumor, lungs, liver, kidney, and aorta. Counts in the regions of interest were decay corrected. Counts/pixel in the tumor under normothermic and hyperthermic conditions were normalized to aorta counts/pixel. A total of 16 cats were eligible for the study. In two of the 16 cats, incomplete count data precluded analysis. In the remaining 14 cats, hyperthermia resulted in a significant increase in liposome accumulation in the tumor (P = 0.001). Tumor volume ranged from 1.2 to 236.2 cm3, and thermal dose ranged from 2.0 to 243.3 CEM43CT90 (equivalent time that the 10th percentile temperature was equal to 43 degrees C). There was not a relationship between either tumor volume or hyperthermia dose on the magnitude of increased liposome accumulation, suggesting that this method has application across a range of tumor volumes and degrees of heatibility.

  8. Technetium-99m-labeled annexin V imaging for detecting prosthetic joint infection in a rabbit model.

    PubMed

    Tang, Cheng; Wang, Feng; Hou, Yanjie; Lu, Shanshan; Tian, Wei; Xu, Yan; Jin, Chengzhe; Wang, Liming

    2015-05-01

    Accurate and timely diagnosis of prosthetic joint infection is essential to initiate early treatment and achieve a favorable outcome. In this study, we used a rabbit model to assess the feasibility of technetium-99m-labeled annexin V for detecting prosthetic joint infection. Right knee arthroplasty was performed on 24 New Zealand rabbits. After surgery, methicillin-susceptible Staphylococcus aureus was intra-articularly injected to create a model of prosthetic joint infection (the infected group, n = 12). Rabbits in the control group were injected with sterile saline (n = 12). Seven and 21 days after surgery, technetium-99m-labeled annexin V imaging was performed in 6 rabbits of each group. Images were acquired 1 and 4 hours after injection of technetium-99m-labeled annexin V (150 MBq). The operated-to-normal-knee activity ratios were calculated for quantitative analysis. Seven days after surgery, increased technetium-99m-labeled annexin V uptake was observed in all cases. However, at 21 days a notable decrease was found in the control group, but not in the infected group. The operated-to-normal-knee activity ratios of the infected group were 1.84 ± 0.29 in the early phase and 2.19 ± 0.34 in the delay phase, both of which were significantly higher than those of the control group (P = 0.03 and P = 0.02). The receiver operator characteristic curve analysis showed that the operated-to-normal-knee activity ratios of the delay phase at 21 days was the best indicator, with an accuracy of 80%. In conclusion, technetium-99m-labeled annexin V imaging could effectively distinguish an infected prosthetic joint from an uninfected prosthetic joint in a rabbit model.

  9. Technetium-99m NGA functional hepatic imaging: preliminary clinical experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stadalnik, R.C.; Vera, D.R.; Woodle, E.S.

    1985-11-01

    Technetium-99m galactosyl-neoglycoalbumin ( (Tc)NGA) is a radiolabeled ligand to hepatic binding protein, a receptor which resides at the plasma membrane of hepatocytes. This receptor-binding radiopharmaceutical and its kinetic model provide a noninvasive method for the assessment of liver function. Eighteen patients were studied: seven with hepatoma, eight with liver metastases, four with cirrhosis, and one patient with acute fulminant non-A, non-B hepatitis. Technetium-99m NGA liver imaging provided anatomic information of diagnostic quality comparable to that obtained with other routine imaging modalities, including computed tomography, angiography, ultrasound, and (Tc)sulfur colloid scintigraphy. Kinetic modeling of dynamic (Tc)NGA data produced estimates of standardizedmore » hepatic blood flow, Q (hepatic blood flow divided by total blood volume), and hepatic binding protein concentration, (HBP). Significant rank correlation was obtained between (HBP) estimates and CTC scores. This correlation supports the hypothesis that (HBP) is a measure of functional hepatocyte mass. The combination of decreased Q and markedly reduced (HBP) may have prognostic significance; all three patients with this combination died of hepatic failure within 6 wk of imaging.« less

  10. Technetium-99m mercaptoacetyltriglycine clearance: reference values for infants and children.

    PubMed

    Schofer, O; König, G; Bartels, U; Bockisch, A; Piepenburg, R; Beetz, R; Meyer, G; Hahn, K

    1995-11-01

    Six hundred and thirty-nine clearance studies performed in children aged 7 days to 19 years utilizing technetium-99m mercaptoacetyltriglycine (MAG 3) were retrospectively analysed. Standardized conditions for the investigation included: parenteral hydration (60 ml/hxm2 body surface) in addition to normal oral fluid intake, weight-related dose of 99mTc-MAG 3 (1 MBq/kg body weight, minimum 15 MBq) and calculation of clearance according to Bubeck et al. Of the 513 children, 169 included in this analysis could be classified as "normal" with regard to their renal function. Normal kidney function was judged by the following criteria: normal GFR for age, normal tubular function (absence of proteinuria and glucosuria), normal renal parenchyma (on ultrasonography, MAG 3 scan and intravenous pyelography), absence of significant obstruction and gross reflux (>grade I), no single kidney and no difference in split renal function >20%. Results showed increasing MAG 3 clearance values for infants during the first months of life, reaching the normal range for older children and adults between 7 and 12 months.

  11. Technetium-99m-HMPAO labeled leukocyte single photon emission computerized tomography (SPECT) for assessing Crohn's disease extent and intestinal infiltration.

    PubMed

    Biancone, L; Schillaci, O; Capoccetti, F; Bozzi, R M; Fina, D; Petruzziello, C; Geremia, A; Simonetti, G; Pallone, F

    2005-02-01

    Scintigraphy using radiolabeled leukocytes is a useful technique for assessing intestinal infiltration in Crohn's disease (CD). However, limits of planar images include overlapping activity in other organs and low specificity. To investigate the usefulness of (99m)Tc-HMPAO (hexametyl propylene amine oxime) labeled leukocyte single photon emission computerized tomography (SPECT) for assessing CD lesions, in comparison with planar images. Twenty-two inflammatory bowel disease patients (19 CD; 2 ulcerative colitis, UC; 1 ileal pouch) assessed by conventional endoscopy or radiology were enrolled. Leukocytes were labeled with (99m)Tc-HMPAO. SPECT images were acquired at 2 h and planar images at 30 min and 2 h. Bowel uptake was quantitated in nine regions (score 0-3). Both SPECT and planar images detected a negative scintigraphy (score 0) in the UC patient with no pouchitis and a positive scintigraphy (score 1-3) in the 21 patients showing active inflammation by conventional techniques. SPECT showed a higher global score than planar images (0.71 +/- 0.09 vs 0.30 +/- 0.05; p < 0.001), and in particular in the right iliac fossa (p= 0.003), right and left flank (p < 0.001; p= 0.02), hypogastrium (p= 0.002), and mesogastrium (p < 0.001). SPECT provided a better visualization and a higher uptake than planar images in patients with ileal and ileocolonic CD (6.45 +/- 0.82 vs 2.8 +/- 0.55, p < 0.001; 5.5 +/- 1.6 vs 2.6 +/- 0.7, p= 0.03), and with perianal CD (6.6 +/- 1.6 vs 3.4 +/- 1.2; p= 0.03). (99m)Tc-HMPAO labeled leukocyte SPECT provides a more detailed visualization of CD lesions than planar images. This technique may better discriminate between intestinal and bone marrow uptake, thus being useful for assessing CD lesions within the pelvis, including perianal disease.

  12. Sensitivity of technetium-99m-pyrophosphate scintigraphy in diagnosing cardiac amyloidosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Falk, R.H.; Lee, V.W.; Rubinow, A.

    1983-03-01

    To determine the value of technetium-99m-pyrophosphate myocardial scintigraphy in the diagnosis of amyloid heart disease this procedure was prospectively performed in 20 consecutive patients with biopsy-proven primary amyloidosis. Eleven patients had echocardiographic abnormalities compatible with amyloid cardiomyopathy, 9 of whom had congestive heart failure. Diffuse myocardial pyrophosphate uptake was of equal or greater intensity than that of the ribs in 9 of the 11 patients with echocardiograms suggestive of amyloidosis, but in only 2 of the 9 with normal echocardiograms, despite abnormal electrocardiograms (p less than 0.01). Increased wall thickness measured by M-mode echocardiography correlated with myocardial pyrophosphate uptake (rmore » . 0.68, p less than 0.01). None of 10 control patients with nonamyloid, nonischemic heart disease had a strongly positive myocardial pyrophosphate uptake. Thus, myocardial technetium-99m-pyrophosphate scanning is a sensitive and specific test for the diagnosis of cardiac amyloidosis in patients with congestive heart failure of obscure origin. It does not appear to be of value for the early detection of cardiac involvement in patients with known primary amyloidosis without echocardiographic abnormalities.« less

  13. Periarticular uptake of /sup 99m/technetium diphosphonate in psoriatics. Correlation with cutaneous activity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Namey, T.C.; Rosenthall, L.

    1976-01-01

    The periarticular uptake of /sup 99m/technetium-labeled diphosphonate (/sup 99m/TcDP) was compared in 12 patients hospitalized for psoriasis and in 12 hospitalized for other dermatoses not associated with arthropathy. The 12 patients with psoriasis had recent onset disease of less than 5 years duration; neither group had historical or clinical evidence of arthritis. All psoriatics had markedly abnormal scans with symmetrically increased periarticular uptake about the imaged joints. None of the controls had similar findings. In 4 patients scanned with /sup 99m/technetium-pertechnetate within 24 hours of their /sup 99m/TcDP scan, no evidence of inflammatory synovitis was found. Three of these patientsmore » were serially imaged with /sup 99m/TcDP at intervals of 2 weeks to 3 months after their initial study, when obvious clinical improvement in their psoriasis was apparent. Improvement in the radionuclide joint images was demonstrated in some of the patients, but none reverted to normal during the study period. In light of recent evidence for the preferential binding of /sup 99m/TcDP to immature collagen, it is suggested that psoriasis may represent a generalized, but uncharacterized, collagen disorder present in bone as well as skin, linking the cutaneous disease with the potential for arthropathy.« less

  14. Scatter and cross-talk correction for one-day acquisition of 123I-BMIPP and 99mtc-tetrofosmin myocardial SPECT.

    PubMed

    Kaneta, Tomohiro; Kurihara, Hideyuki; Hakamatsuka, Takashi; Ito, Hiroshi; Maruoka, Shin; Fukuda, Hiroshi; Takahashi, Shoki; Yamada, Shogo

    2004-12-01

    123I-15-(p-iodophenyl)-3-(R,S)-methylpentadecanoic acid (BMIPP) and 99mTc-tetrofosmin (TET) are widely used for evaluation of myocardial fatty acid metabolism and perfusion, respectively. ECG-gated TET SPECT is also used for evaluation of myocardial wall motion. These tests are often performed on the same day to minimize both the time required and inconvenience to patients and medical staff. However, as 123I and 99mTc have similar emission energies (159 keV and 140 keV, respectively), it is necessary to consider not only scattered photons, but also primary photons of each radionuclide detected in the wrong window (cross-talk). In this study, we developed and evaluated the effectiveness of a new scatter and cross-talk correction imaging protocol. Fourteen patients with ischemic heart disease or heart failure (8 men and 6 women with a mean age of 69.4 yr, ranging from 45 to 94 yr) were enrolled in this study. In the routine one-day acquisition protocol, BMIPP SPECT was performed in the morning, with TET SPECT performed 4 h later. An additional SPECT was performed just before injection of TET with the energy window for 99mTc. These data correspond to the scatter and cross-talk factor of the next TET SPECT. The correction was performed by subtraction of the scatter and cross-talk factor from TET SPECT. Data are presented as means +/- S.E. Statistical analyses were performed using Wilcoxon's matched-pairs signed-ranks test, and p < 0.05 was considered significant. The percentage of scatter and cross-talk relative to the corrected total count was 26.0 +/- 5.3%. EDV and ESV after correction were significantly greater than those before correction (p = 0.019 and 0.016, respectively). After correction, EF was smaller than that before correction, but the difference was not significant. Perfusion scores (17 segments per heart) were significantly lower after as compared with those before correction (p < 0.001). Scatter and cross-talk correction revealed significant differences

  15. A solvent-extraction module for cyclotron production of high-purity technetium-99m.

    PubMed

    Martini, Petra; Boschi, Alessandra; Cicoria, Gianfranco; Uccelli, Licia; Pasquali, Micòl; Duatti, Adriano; Pupillo, Gaia; Marengo, Mario; Loriggiola, Massimo; Esposito, Juan

    2016-12-01

    The design and fabrication of a fully-automated, remotely controlled module for the extraction and purification of technetium-99m (Tc-99m), produced by proton bombardment of enriched Mo-100 molybdenum metallic targets in a low-energy medical cyclotron, is here described. After dissolution of the irradiated solid target in hydrogen peroxide, Tc-99m was obtained under the chemical form of 99m TcO 4 - , in high radionuclidic and radiochemical purity, by solvent extraction with methyl ethyl ketone (MEK). The extraction process was accomplished inside a glass column-shaped vial especially designed to allow for an easy automation of the whole procedure. Recovery yields were always >90% of the loaded activity. The final pertechnetate saline solution Na 99m TcO 4 , purified using the automated module here described, is within the Pharmacopoeia quality control parameters and is therefore a valid alternative to generator-produced 99m Tc. The resulting automated module is cost-effective and easily replicable for in-house production of high-purity Tc-99m by cyclotrons. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Intraoperative Injection of Technetium-99m Sulfur Colloid for Sentinel Lymph Node Biopsy in Breast Cancer Patients: A Single Institution Experience.

    PubMed

    Berrocal, Julian; Saperstein, Lawrence; Grube, Baiba; Horowitz, Nina R; Chagpar, Anees B; Killelea, Brigid K; Lannin, Donald R

    2017-01-01

    Background . Most institutions require a patient undergoing sentinel lymph node biopsy to go through nuclear medicine prior to surgery to be injected with radioisotope. This study describes the long-term results using intraoperative injection of radioisotope. Methods . Since late 2002, all patients undergoing a sentinel lymph node biopsy at the Yale-New Haven Breast Center underwent intraoperative injection of technetium-99m sulfur colloid. Endpoints included number of sentinel and nonsentinel lymph nodes obtained and number of positive sentinel and nonsentinel lymph nodes. Results . At least one sentinel lymph node was obtained in 2,333 out of 2,338 cases of sentinel node biopsy for an identification rate of 99.8%. The median number of sentinel nodes found was 2 and the mean was 2.33 (range: 1-15). There were 512 cases (21.9%) in which a sentinel node was positive for metastatic carcinoma. Of the patients with a positive sentinel lymph node who underwent axillary dissection, there were 242 cases (54.2%) with no additional positive nonsentinel lymph nodes. Advantages of intraoperative injection included increased comfort for the patient and simplification of scheduling. There were no radiation related complications. Conclusion . Intraoperative injection of technetium-99m sulfur colloid is convenient, effective, safe, and comfortable for the patient.

  17. Intraoperative Injection of Technetium-99m Sulfur Colloid for Sentinel Lymph Node Biopsy in Breast Cancer Patients: A Single Institution Experience

    PubMed Central

    Berrocal, Julian; Saperstein, Lawrence; Grube, Baiba; Horowitz, Nina R.; Chagpar, Anees B.

    2017-01-01

    Background. Most institutions require a patient undergoing sentinel lymph node biopsy to go through nuclear medicine prior to surgery to be injected with radioisotope. This study describes the long-term results using intraoperative injection of radioisotope. Methods. Since late 2002, all patients undergoing a sentinel lymph node biopsy at the Yale-New Haven Breast Center underwent intraoperative injection of technetium-99m sulfur colloid. Endpoints included number of sentinel and nonsentinel lymph nodes obtained and number of positive sentinel and nonsentinel lymph nodes. Results. At least one sentinel lymph node was obtained in 2,333 out of 2,338 cases of sentinel node biopsy for an identification rate of 99.8%. The median number of sentinel nodes found was 2 and the mean was 2.33 (range: 1–15). There were 512 cases (21.9%) in which a sentinel node was positive for metastatic carcinoma. Of the patients with a positive sentinel lymph node who underwent axillary dissection, there were 242 cases (54.2%) with no additional positive nonsentinel lymph nodes. Advantages of intraoperative injection included increased comfort for the patient and simplification of scheduling. There were no radiation related complications. Conclusion. Intraoperative injection of technetium-99m sulfur colloid is convenient, effective, safe, and comfortable for the patient. PMID:28492062

  18. Technetium-99m production issues in the United Kingdom.

    PubMed

    Green, Christopher H

    2012-04-01

    Nuclear Medicine developed when it was realised that a radioisotopic substitution of Iodine-131 for the stable Iodine-127 would follow the same metabolic pathway in the body enabling the thyroid to be imaged and the thyroid uptake measured. The Iodine could be complexed with pharmaceutical substrates to enable other organs to be imaged, but its use was limited and high gamma energy and beta emission restricted the activity of each radiopharmaceutical used, leading to long acquisition times and degraded images. As a pure gamma emitter of 140 keV and with a 6-h half-life, Technetium-99m is a better radionuclide and images a wider range of bodily organs. However, its short half-life also requires it to be eluted from its mother radionuclide, Mo-99, in a generator, delivered weekly from radiopharmaceutical companies who obtain the Mo-99 in liquid form from high-flux research reactors. All went well till around 2007, when the NRU Reactor in Canada was closed and all other reactors went down for various periods for unrelated problems, leading to widespread Mo-99 shortages. Although the reactors have since recovered, they are 48 to 57 years old, and it seems that few governments have made any future provision such as building replacement reactors.

  19. Technetium-99m production issues in the United Kingdom

    PubMed Central

    Green, Christopher H.

    2012-01-01

    Nuclear Medicine developed when it was realised that a radioisotopic substitution of Iodine-131 for the stable Iodine-127 would follow the same metabolic pathway in the body enabling the thyroid to be imaged and the thyroid uptake measured. The Iodine could be complexed with pharmaceutical substrates to enable other organs to be imaged, but its use was limited and high gamma energy and beta emission restricted the activity of each radiopharmaceutical used, leading to long acquisition times and degraded images. As a pure gamma emitter of 140 keV and with a 6-h half-life, Technetium-99m is a better radionuclide and images a wider range of bodily organs. However, its short half-life also requires it to be eluted from its mother radionuclide, Mo-99, in a generator, delivered weekly from radiopharmaceutical companies who obtain the Mo-99 in liquid form from high-flux research reactors. All went well till around 2007, when the NRU Reactor in Canada was closed and all other reactors went down for various periods for unrelated problems, leading to widespread Mo-99 shortages. Although the reactors have since recovered, they are 48 to 57 years old, and it seems that few governments have made any future provision such as building replacement reactors. PMID:22557795

  20. Technetium-99m generator system

    DOEpatents

    Mirzadeh, Saed; Knapp, Jr., Furn F.; Collins, Emory D.

    1998-01-01

    A .sup.99 Mo/.sup.99m Tc generator system includes a sorbent column loaded with a composition containing .sup.99 Mo. The sorbent column has an effluent end in fluid communication with an anion-exchange column for concentrating .sup.99m Tc eluted from the sorbent column. A method of preparing a concentrated solution of .sup.99m Tc includes the general steps of: a. providing a sorbent column loaded with a composition containing .sup.99 Mo, the sorbent column having an effluent end in fluid communication with an anion-exchange column; b. eluting the sorbent column with a salt solution to elute .sup.99m Tc from the sorbent and to trap and concentrate the eluted .sup.99m Tc on the ion-exchange column; and c. eluting the concentrated .sup.99m Tc from the ion-exchange column with a solution comprising a reductive complexing agent.

  1. Technetium-99m generator system

    DOEpatents

    Mirzadeh, S.; Knapp, F.F. Jr.; Collins, E.D.

    1998-06-30

    A {sup 99}Mo/{sup 99m}Tc generator system includes a sorbent column loaded with a composition containing {sup 99}Mo. The sorbent column has an effluent end in fluid communication with an anion-exchange column for concentrating {sup 99m}Tc eluted from the sorbent column. A method of preparing a concentrated solution of {sup 99m}Tc includes the general steps of: (a) providing a sorbent column loaded with a composition containing {sup 99}Mo, the sorbent column having an effluent end in fluid communication with an anion-exchange column; (b) eluting the sorbent column with a salt solution to elute {sup 99m}Tc from the sorbent and to trap and concentrate the eluted {sup 99m}Tc on the ion-exchange column; and (c) eluting the concentrated {sup 99m}Tc from the ion-exchange column with a solution comprising a reductive complexing agent. 1 fig.

  2. Images of liposarcoma using technetium-99m bleomycin and technetium (V)-99m DMSA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ohta, H.; Shane, F.I.; Endo, K.

    1986-12-01

    The effectiveness of Tc-99m bleomycin (BLM) and Tc(V)-99m DMSA are compared with that of Ga-67 citrate, which is currently the most widely used agent. In four patients with lipomatous tumors, the clinical significance of tumor imaging with each of these three agents is discussed and compared. Results indicate that both Tc-99m BLM and Tc(V)-99m DMSA are superior in detecting the extension or localization of liposarcomas.

  3. Guava extract (Psidium guajava) alters the labelling of blood constituents with technetium-99m.

    PubMed

    Abreu, P R C; Almeida, M C; Bernardo, R M; Bernardo, L C; Brito, L C; Garcia, E A C; Fonseca, A S; Bernardo-Filho, M

    2006-06-01

    Psidium guajava (guava) leaf is a phytotherapic used in folk medicine to treat gastrointestinal and respiratory disturbances and is used as anti-inflammatory medicine. In nuclear medicine, blood constituents (BC) are labelled with technetium-99m ((99m)Tc) and used to image procedures. However, data have demonstrated that synthetic or natural drugs could modify the labelling of BC with (99m)Tc. The aim of this work was to evaluate the effects of aqueous extract of guava leaves on the labelling of BC with (99m)Tc. Blood samples of Wistar rats were incubated with different concentrations of guava extract and labelled with (99m)Tc after the percentage of incorporated radioactivity (%ATI) in BC was determined. The results suggest that aqueous guava extract could present antioxidant action and/or alters the membrane structures involved in ion transport into cells, thus decreasing the radiolabelling of BC with (99m)Tc. The data showed significant (P<0.05) alteration of ATI in BC from blood incubated with guava extract.

  4. Guava extract (Psidium guajava) alters the labelling of blood constituents with technetium-99m*

    PubMed Central

    Abreu, P.R.C.; Almeida, M.C.; Bernardo, R.M.; Bernardo, L.C.; Brito, L.C.; Garcia, E.A.C.; Fonseca, A.S.; Bernardo-Filho, M.

    2006-01-01

    Psidium guajava (guava) leaf is a phytotherapic used in folk medicine to treat gastrointestinal and respiratory disturbances and is used as anti-inflammatory medicine. In nuclear medicine, blood constituents (BC) are labelled with technetium-99m (99mTc) and used to image procedures. However, data have demonstrated that synthetic or natural drugs could modify the labelling of BC with 99mTc. The aim of this work was to evaluate the effects of aqueous extract of guava leaves on the labelling of BC with 99mTc. Blood samples of Wistar rats were incubated with different concentrations of guava extract and labelled with 99mTc after the percentage of incorporated radioactivity (%ATI) in BC was determined. The results suggest that aqueous guava extract could present antioxidant action and/or alters the membrane structures involved in ion transport into cells, thus decreasing the radiolabelling of BC with 99mTc. The data showed significant (P<0.05) alteration of ATI in BC from blood incubated with guava extract. PMID:16691636

  5. Identification of Warthin tumor: magnetic resonance imaging versus salivary scintigraphy with technetium-99m pertechnetate.

    PubMed

    Motoori, Ken; Ueda, Takuya; Uchida, Yoshitaka; Chazono, Hideaki; Suzuki, Homare; Ito, Hisao

    2005-01-01

    The aim of this study was to evaluate the accuracy of technetium-99m (Tc-99m) pertechnetate scintigraphy and magnetic resonance (MR) imaging in the diagnosis of Warthin tumor. Sixteen cases of Warthin tumor and 17 cases of non-Warthin tumor were examined by Tc-99m pertechnetate scintigraphy with lemon juice stimulation and MR imaging, including T1-weighted, T2-weighted, short inversion time inversion recovery, diffusion-weighted, and contrast-enhanced dynamic images. We used the receiver operating characteristic (ROC) curve to evaluate diagnostic accuracy. The mean area under the ROC curves of MR imaging in the diagnosis of Warthin tumor (0.97) was higher than that of Tc-99m pertechnetate scintigraphy (0.88). Magnetic resonance imaging is more useful in the evaluation of Warthin tumor than Tc-99m pertechnetate scintigraphy.

  6. Single photon emission tomography using 99mTc-HM-PAO in the investigation of dementia.

    PubMed Central

    Neary, D; Snowden, J S; Shields, R A; Burjan, A W; Northen, B; MacDermott, N; Prescott, M C; Testa, H J

    1987-01-01

    Single photon emission tomographic imaging of the brain using 99mTc HM-PAO was carried out in patients with a clinical diagnosis of Alzheimer's disease, non-Alzheimer frontal-lobe dementia, and progressive supranuclear palsy. Independent assessment of reductions in uptake revealed posterior hemisphere abnormalities in the majority of the Alzheimer group, and selective anterior hemisphere abnormalities in both other groups. The findings were consistent with observed patterns of mental impairment. The imaging technique has potential value in the differential diagnosis of primary cerebral atrophy. Images PMID:3499484

  7. Lung ventilation studies with technetium-99m Pseudogas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burch, W.M.; Sullivan, P.J.; Lomas, F.E.

    1986-06-01

    Technetium-99m Pseudogas is an ultrafine near monodisperse aerosol of 0.12-microgram diam particle size. This report describes initial clinical experiences with 27 patients referred for investigation of suspected pulmonary embolism, and in whom Pseudogas ventilation images were compared with a high quality commercial aerosol. An additional group of ten patients with severe COPD was examined in a comparative trial of Pseudogas with 81mKr. Pseudogas was better than a conventional aerosol in reaching a diagnosis of pulmonary embolism using a simple blinded comparison with coded images. In addition, bronchial deposition was minimal unless COPD was severe. Moderately well patients had no difficultymore » inhaling the necessary activity in one or two breaths, and even severely ill and frail aged persons could accomplish the passive breathing maneuver in less than a minute. Clearance of Pseudogas was directly to the systemic circulation with a half-time of 10 min in normal subjects extending up to 100 min in patients with airways disease.« less

  8. Structural and Perfusion Abnormalities of Brain on MRI and Technetium-99m-ECD SPECT in Children With Cerebral Palsy: A Comparative Study.

    PubMed

    Rana, Kamer Singh; Narwal, Varun; Chauhan, Lokesh; Singh, Giriraj; Sharma, Monica; Chauhan, Suneel

    2016-04-01

    Cerebral palsy has traditionally been associated with hypoxic ischemic brain damage. This study was undertaken to demonstrate structural and perfusion brain abnormalities. Fifty-six children diagnosed clinically as having cerebral palsy were studied between 1 to 14 years of age and were subjected to 3 Tesla magnetic resonance imaging (MRI). Brain and Technetium-99m-ECD brain single-photon emission computed tomography (SPECT) scan. Male to female ratio was 1.8:1 with a mean age of 4.16 ± 2.274 years. Spastic cerebral palsy was the most common type, observed in 91%. Birth asphyxia was the most common etiology (69.6%). White matter changes (73.2%) such as periventricular leukomalacia and corpus callosal thinning were the most common findings on MRI. On SPECT all cases except one revealed perfusion impairments in different regions of brain. MRI is more sensitive in detecting white matter changes, whereas SPECT is better in detecting cortical and subcortical gray matter abnormalities of perfusion. © The Author(s) 2015.

  9. Technetium tc 99m-labeled red blood cells in the preoperative diagnosis of cavernous hemangioma and other vascular orbital tumors.

    PubMed

    Polito, Ennio; Burroni, Luca; Pichierri, Patrizia; Loffredo, Antonio; Vattimo, Angelo G

    2005-12-01

    To evaluate technetium Tc 99m (99mTc) red blood cell scintigraphy as a diagnostic tool for orbital cavernous hemangioma and to differentiate between orbital masses on the basis of their vascularization. We performed 99mTc red blood cell scintigraphy on 23 patients (8 female and 15 male; mean age, 47 years) affected by an orbital mass previously revealed with computed tomography (CT) and magnetic resonance imaging (MRI) and suggesting cavernous hemangioma. In our diagnosis, we considered the orbital increase delayed uptake with the typical scintigraphic pattern known as perfusion blood pool mismatch. The patients underwent biopsy or surgical treatment with transconjunctival cryosurgical extraction when possible. Single-photon emission tomography (SPET) showed intense focal uptake in the orbit corresponding to radiologic findings in 11 patients who underwent surgical treatment and pathologic evaluation (9 cavernous hemangiomas, 1 hemangiopericytoma, and 1 lymphangioma). Clinical or histologic examination of the remaining 22 patients revealed the presence of 5 lymphoid pseudotumors, 2 lymphomas, 2 pleomorphic adenomas of the lacrimal gland, 1 astrocytoma, 1 ophthalmic vein thrombosis, and 1 orbital varix. The confirmation of the preoperative diagnosis by 99mTc red blood cell scintigraphy shows that this technique is a reliable tool for differentiating cavernous hemangiomas from other orbital masses (sensitivity, 100%; specificity, 86%) when ultrasound, CT, and MRI are not diagnostic. Unfortunately, 99mTc red blood cell scintigraphy results were positive in 1 patient with hemangiopericytoma and 1 patient with lymphangioma, which showed increased uptake in the lesion on SPET images because of the vascular nature of these tumors. Therefore, in these cases, the SPET images have to be integrated with data regarding clinical preoperative evaluation and CT scans or MRI studies. On the basis of our study, a complete diagnostic picture, CT scans or MRI studies, and

  10. Technetium-99m-labeled ceftizoxime loaded long-circulating and pH-sensitive liposomes used to identify osteomyelitis.

    PubMed

    Ferreira, Soraya Maria Zandim Maciel Dias; Domingos, Giselle Pires; Ferreira, Diego dos Santos; Rocha, Talita Guieiro Ribeiro; Serakides, Rogéria; de Faria Rezende, Cleuza Maria; Cardoso, Valbert Nascimento; Fernandes, Simone Odília Antunes; Oliveira, Mônica Cristina

    2012-07-15

    Osteomyelitis is an infectious disease located in the bone or bone marrow. Long-circulating and pH-sensitive liposomes containing a technetium-99m-labeled antibiotic, ceftizoxime, (SpHL-(99m)Tc-CF) were developed to identify osteomyelitis foci. Biodistribution studies and scintigraphic images of bone infection or non infection-bearing rats that had been treated with these liposomes were performed. A high accumulation in infectious foci and high values in the target-non target ratio could be observed. These results indicate the potential of SpHL-(99m)Tc-CF as a potential agent for the diagnosis of bone infections. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Evaluation of technetium-99m decay on Escherichia coli inactivation: effects of physical or chemical agents.

    PubMed Central

    Silva, C. R.; Valsa, J. O.; Caniné, M. S.; Caldeira-de-Araújo, A.; Bernardo-Filho, M.

    1998-01-01

    Technetium-99m (99mTc) has been used in nuclear medicine and in biomedical research to label molecular and cellular structures employed as radiotracers. Here, we have evaluated, on a DNA repair proficient Escherichia coli strain, the 99mTc decay inactivation and the influence of the (i) pre-treatment with metal ion chelators or of the (ii) treatment with a free radical scavenger on the protection of the cells against the lethal effect of the 99mTc. As SnCl2 is frequently used as a reducing agent in the 99mTc-labeling process, we have also studied the capability of SnCl2 to alter the biological effects induced by the 99mTc decay. As we are exposed to either chemical or physical agents in the nature, we have decided to study a possible influence of the ultraviolet solar radiation in the biological phenomena induced by the 99mTc decay. Our data point out (i) a very important role of the Auger and/or conversion electrons in the cytotoxicity induced by the 99mTc decay; (ii) SnCl2, the metal ion chelators and the free radical scavenger protect the cells against the lethal effect of the 99mTc; and (iii) near-UV does not alter the lethal effect of the 99mTc decay. PMID:9713950

  12. Comparison of technetium-99m-HMPAO and technetium-99m-ECD cerebral SPECT images in Alzheimer`s disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dyck, C.H. van; Lin, C.H.; Smith, E.O.

    1996-11-01

    SPECT has shown increasing promise as a diagnostic tool in Alzheimer`s disease (AD). Recently, a new SPECT brain perfusion agent, {sup 99m}Tc-ethyl cysteinate dimer ({sup 99m}Tc-ECD) has emerged with purported advantages in image quality over the established tracer, {sup 99m}Tc-hexamethylpropyleneamine oxime ({sup 99m}Tc-HMPAO). This research aimed to compare cerebral images for ({sup 99m}Tc-HMPAO). This research aimed to compare cerebral images for {sup 99}mTc-HMPAO and {sup 99m}Tc-ECD in discriminating patients with AD form control subjects. 51 refs., 5 figs., 3 tabs.

  13. Enterogastroesophageal reflux detected on 99m-technetium sestamibi cardiac imaging as a cause of chest pain

    PubMed Central

    Erdoğan, Zeynep; Silov, Güler; Özdal, Ayşegül; Turhal, Özgül

    2013-01-01

    Myocardial perfusion imaging (MPI) with technetium-99m sestamibi (Tc-99m MIBI) is considered a diagnostic technique that is widely used for the investigation of suspected coronary artery disease. Incidental inspection of an extracardiac activity is indirect, but important marker, which can identify a potentially treatable non-coronary cause for chest pain that may mimic cardiac symptoms. Here, we present an illustrative case in which significant enterogastroesophageal reflux of Tc-99m MIBI occurred during the cardiac imaging following prompt hepatobiliary clearance. Because, there was normal myocardial perfusion on MPI, presence of gastroesophageal reflux (GER) on GER scintigraphy and detection of mild inflammation with pathologically confirmed hyperplastic polyp by endoscopy, in view of the above findings we concluded that the probable cause of chest pain was reflux. PMID:24019679

  14. Variable uptake feature of focal nodular hyperplasia in Tc-99m phytate hepatic scintigraphy/single-photon emission computed tomography-A parametric analysis.

    PubMed

    Hsu, Yu-Ling; Chen, Yu-Wen; Lin, Chia-Yang; Lai, Yun-Chang; Chen, Shinn-Cherng; Lin, Zu-Yau

    2015-12-01

    Tc-99m phytate hepatic scintigraphy remains the standard method for evaluating the functional features of Kupffer cells. In this study, we demonstrate the variable uptake feature of focal nodular hyperplasia (FNH) in Tc-99m phytate scintigraphy. We reviewed all patients who underwent Tc-99m phytate hepatic scintigraphy between 2008 and 2012 in Kaohsiung Medical University Hospital, Kaohsiung, Taiwan. Cases with FNH were diagnosed on the basis of pathology or at least one or more prior imaging with a periodic clinical follow-up. All patients received a standard protocol of dynamic flow study and planar and Tc-99m phytate single-photon emission computed tomography (E. CAM; Siemens). The correlation of variable nodular radioactivity with parameters such as tumor size and localization was analyzed. In total, 15 lesions of 14 patients in the clinic were diagnosed as FNH. The tumor size was approximately 2.9-7.4 cm (mean size 4.6 cm). Four lesions were larger than 5 cm. The major anatomic distribution was in the right hepatic lobe (10 lesions), particularly in the superior segments (7 lesions). Tc-99m phytate single-photon emission computed tomography imaging for determining the functional features of Kupffer cells included cool/cold (8 lesions), isoradioactive/warm (6 lesions), and hot (1 lesion) patterns of uptake. We did not observe any statistically significant correlation between variable nodular radioactivity and tumor size (p=0.68) or localization (p=0.04). Herein, we demonstrate the variable uptake feature of FNH in Tc-99m phytate scintigraphy. In small FNH tumors (< 5 cm), increased or equal uptake still provided specificity for the differential diagnosis of hepatic solid tumors. Copyright © 2015. Published by Elsevier Taiwan.

  15. Detection of homing-in of stem cells labeled with technetium-99m hexamethylpropyleneamine oxime in infarcted myocardium after intracoronary injection

    PubMed Central

    Patel, Chetan D; Agarwal, Snehlata; Seth, Sandeep; Mohanty, Sujata; Aggarwal, Himesh; Gupta, Namit

    2014-01-01

    Bone marrow stem cells having myogenic potential are promising candidates for various cell-based therapies for myocardial disease. We present here images showing homing of technetium-99m (Tc-99m) hexamethylpropyleneamine oxime (HMPAO) labeled stem cells in the infarcted myocardium from a pilot study conducted to radio-label part of the stem cells in patients enrolled in a stem cell clinical trial for recent myocardial infarction. PMID:25400375

  16. Clinical application of calculated split renal volume using computed tomography-based renal volumetry after partial nephrectomy: Correlation with technetium-99m dimercaptosuccinic acid renal scan data.

    PubMed

    Lee, Chan Ho; Park, Young Joo; Ku, Ja Yoon; Ha, Hong Koo

    2017-06-01

    To evaluate the clinical application of computed tomography-based measurement of renal cortical volume and split renal volume as a single tool to assess the anatomy and renal function in patients with renal tumors before and after partial nephrectomy, and to compare the findings with technetium-99m dimercaptosuccinic acid renal scan. The data of 51 patients with a unilateral renal tumor managed by partial nephrectomy were retrospectively analyzed. The renal cortical volume of tumor-bearing and contralateral kidneys was measured using ImageJ software. Split estimated glomerular filtration rate and split renal volume calculated using this renal cortical volume were compared with the split renal function measured with technetium-99m dimercaptosuccinic acid renal scan. A strong correlation between split renal function and split renal volume of the tumor-bearing kidney was observed before and after surgery (r = 0.89, P < 0.001 and r = 0.94, P < 0.001). The preoperative and postoperative split estimated glomerular filtration rate of the operated kidney showed a moderate correlation with split renal function (r = 0.39, P = 0.004 and r = 0.49, P < 0.001). The correlation between reductions in split renal function and split renal volume of the operated kidney (r = 0.87, P < 0.001) was stronger than that between split renal function and percent reduction in split estimated glomerular filtration rate (r = 0.64, P < 0.001). The split renal volume calculated using computed tomography-based renal volumetry had a strong correlation with the split renal function measured using technetium-99m dimercaptosuccinic acid renal scan. Computed tomography-based split renal volume measurement before and after partial nephrectomy can be used as a single modality for anatomical and functional assessment of the tumor-bearing kidney. © 2017 The Japanese Urological Association.

  17. A tracer dose of technetium-99m-labeled liposomes can estimate the effect of hyperthermia on intratumoral doxil extravasation.

    PubMed

    Kleiter, Miriam M; Yu, Daohai; Mohammadian, Lenore A; Niehaus, Nelsen; Spasojevic, Ivan; Sanders, Linda; Viglianti, Benjamin L; Yarmolenko, Pavel S; Hauck, Marlene; Petry, Neil A; Wong, Terence Z; Dewhirst, Mark W; Thrall, Donald E

    2006-11-15

    A noninvasive method to monitor intratumoral Doxil delivery in individual patients during targeted tumor therapy is important to predict treatment response. The purpose of this study was to determine if a small tracer dose of technetium-99m (99mTc)-labeled liposomes could be used to quantify the effect of local hyperthermia on intratumoral Doxil extravasation. Experiments were carried out in a rat fibrosarcoma model with transplanted thigh tumors. Liposomes of approximately same size and composition as Doxil were radiolabeled using [technetium-99m (99mTc)]exametazime. Eight treatment groups received either Doxil, a tracer dose or a large dose of 99mTc-labeled liposomes, or a combination of tracer and Doxil, with or without hyperthermia. This design was chosen to assure that coadministration of both liposomal formulations did not influence their intratumoral distribution. Hyperthermia was done for 45 minutes. Scintigraphic images were obtained at 5 and 18 hours. At 18 hours, tumors were removed and gamma counts as well as doxorubicin concentrations were measured. Intratumoral extravasation of the 99mTc-labeled tracer could be imaged scintigraphically under normothermic and hyperthermic conditions. The thermal enhancement ratio was slightly higher for radiolabeled liposomes than for doxorubicin concentration. However, there was a significant positive correlation of intratumoral doxorubicin concentration and intratumoral uptake of the radiolabeled tracer (expressed as percentage of the injected dose per gram of tissue). Coadministration of radiolabeled liposomes did not negatively influence the amount of drug delivered with Doxil. The use of a radiolabeled tracer has potential value to monitor drug delivery and estimate the effect of an intervention aimed to increase liposomal accumulation, such as local hyperthermia.

  18. Technetium-99m stannous pyrophosphate myocardial scintigraphy after cardiopulmonary resuscitation with cardioversion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davison, R.; Spies, S.M.; Przybylek, J.

    1979-08-01

    Thirty consecutive patients underwent technetium-99m stannous pyrophosphate myocardial scintigraphy 48 to 72 h after successful cardiopulmonary resuscitation and direct current cardioversion. Five patients with transmural myocardial infarctions by ECG and enzyme determinations were correctly identified by scintigraphy. Myocardial scans were positive in five of nine patients with nontransmural infarction. Of 16 patients without evidence of myocardial infarction, only two (13%) had false-positive myocardial scans. The overall accuracy of imaging in this series was 80%. We conclude that false-positive scans after cardiopulmonary resuscitation with electrical cardioversion are infrequent, and do not significantly detract from the value of myocardial scintigraphy in themore » diagnosis of myocardial infarction.« less

  19. Rhenium and technetium complexes that bind to amyloid-β plaques.

    PubMed

    Hayne, David J; North, Andrea J; Fodero-Tavoletti, Michelle; White, Jonathan M; Hung, Lin W; Rigopoulos, Angela; McLean, Catriona A; Adlard, Paul A; Ackermann, Uwe; Tochon-Danguy, Henri; Villemagne, Victor L; Barnham, Kevin J; Donnelly, Paul S

    2015-03-21

    Alzheimer's disease is associated with the presence of insoluble protein deposits in the brain called amyloid plaques. The major constituent of these deposits is aggregated amyloid-β peptide. Technetium-99m complexes that bind to amyloid-β plaques could provide important diagnostic information on amyloid-β plaque burden using Single Photon Emission Computed Tomography (SPECT). Tridentate ligands with a stilbene functional group were used to form complexes with the fac-[M(I)(CO)3](+) (M = Re or (99m)Tc) core. The rhenium carbonyl complexes with tridentate co-ligands that included a stilbene functional group and a dimethylamino substituent bound to amyloid-β present in human frontal cortex brain tissue from subjects with Alzheimer's disease. This chemistry was extended to make the analogous [(99m)Tc(I)(CO)3](+) complexes and the complexes were sufficiently stable in human serum. Whilst the lipophilicity (log D7.4) of the technetium complexes appeared ideally suited for penetration of the blood-brain barrier, preliminary biodistribution studies in an AD mouse model (APP/PS1) revealed relatively low brain uptake (0.24% ID g(-1) at 2 min post injection).

  20. Method of tagging excipients with /sup 99m/Tc

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bardy, A.; Beydon, J.; Gobin, R.

    1977-11-08

    A method of using /sup 99m/technetium for tagging excipients in medical diagnosis by scintigraphy comprises mixing, in an aqueous solution of alkali-metal pertechnetate, an excipient and a reducing agent in the form of a complex, which complex is such that the association constant of the anion with reduced techetium is less than the association constant of the excipient with reduced technetium, thereby forming a radio-pharmaceutical substance which is a complex between the excipient and /sup 99m/technetium.

  1. Imaging experimental intraabdominal abscesses with 99mTc-PEG liposomes and 99mTc-HYNIC IgG.

    PubMed Central

    Dams, E T; Reijnen, M M; Oyen, W J; Boerman, O C; Laverman, P; Storm, G; van der Meer, J W; Corstens, F H; van Goor, H

    1999-01-01

    OBJECTIVE: To evaluate the accuracy of technetium-99m-labeled polyethylene glycol-coated liposomes (99mTc-PEG liposomes) and technetium-99m-labeled nonspecific human immunoglobulin G (99mTc-HYNIC IgG) for the scintigraphic detection of experimental intraabdominal abscesses in comparison with that of a standard agent, gallium-67 citrate. BACKGROUND: Scintigraphic imaging techniques can be very useful for the rapid and accurate localization of intraabdominal abscesses. Two newly developed radiolabeled agents, 99mTc-PEG liposomes and 99mTc-HYNIC IgG, have shown to be excellent agents for imaging experimental focal infection, but have not yet been studied in the detection of abdominal abscesses. METHODS: Intraabdominal abscesses were induced in 42 rats using the cecal ligation and puncture technique. Seven days later, randomized groups of rats received 99mTc-PEG liposomes, 99mTc-HYNIC IgG, or 67Ga citrate intravenously. The rats were imaged up to 24 hours after the injection. The biodistribution of the radiolabel was determined by counting dissected tissues ex vivo. Macroscopic intraabdominal abnormalities and focal uptake on the images were independently scored on a semiquantitative scale. RESULTS: 99mTc-PEG liposomes provided the earliest scintigraphic visualization of the abscess (as soon as 2 hours after the injection vs. 4 hours for the other two agents). Liposomes, IgG, and gallium all showed similarly high absolute uptake in the abscess. Focal uptake of liposomes and gallium correlated best with the extent of the macroscopic abnormalities. CONCLUSIONS: 99mTc-PEG liposomes and 99mTc-HYNIC IgG performed at least as well as the standard agent, 67Ga citrate, in the detection of experimental intraabdominal abscesses, with obvious advantages such as lower radiation exposure and more favorable physical properties. Of the two technetium agents, the liposomes seemed to be superior, providing the earliest diagnostic image and the best correlation with the inflammatory

  2. Low-activity 124I-PET/low-dose CT versus 99mTc-pertechnetate planar scintigraphy or 99mTc-pertechnetate single-photon emission computed tomography of the thyroid: a pilot comparison.

    PubMed

    Darr, Andreas M; Opfermann, Thomas; Niksch, Tobias; Driesch, Dominik; Marlowe, Robert J; Freesmeyer, Martin

    2013-10-01

    The standard thyroid functional imaging method, 99mTc-pertechnetate (99mTc-PT) planar scintigraphy, has technical drawbacks decreasing its sensitivity in detecting nodules or anatomical pathology. 124I-PET, lacking these disadvantages and allowing simultaneous CT, may have greater sensitivity for these purposes. We performed a blinded pilot comparison of 124I-PET(/CT) versus 99mTc-PT planar scintigraphy or its cross-sectional enhancement, 99mTc-PT single-photon emission CT (SPECT), in characterizing the thyroid gland with benign disease. Twenty-one consecutive adults with goiter underwent low-activity (1 MBq/0.027 mCi) 124I-PET/low-dose (30 mAs) CT, 99mTc-PT planar scintigraphy, and 99mTc-PT-SPECT. Endpoints included the numbers of “hot spots” with/without central photopenia and “cold spots” detected, the proportion of these lesions with morphological correlates, the mean volume and diameter of visualized nodules, and the number of cases of lobus pyramidalis or retrosternal thyroid tissue identified. 124I-PET detected significantly more “hot spots” with/without central photopenia (P < 0.001), significantly more nodules (P < 0.001), and more “cold spots” than did 99mTc-PT planar scintigraphy or 99mTc-PT-SPECT, including all lesions seen on the 99mTc-PT modalities. Ultrasonographic correlates were found for all nodules visualized on all 3 modalities and 92.5% of nodules seen only on 124I-PET. Nodules discernible only on 124I-PET had significantly smaller mean volume or diameter (P < 0.001) than did those visualized on 99mTc-PT planar scintigraphy or 99mTc-PT-SPECT. 124I-PET(/CT) identified significantly more patients with a lobus pyramidalis (P < 0.001) or retrosternal thyroid tissue (P < 0.05). 124I-PET(/CT) may provide superior imaging of benign thyroid disease compared to planar or cross-sectional 99mTc-PT scintigraphy.

  3. Scintigraphic detection of occult hemorrhage using RBCs labeled in vitro with technetium Tc 99m sodium pertechnetate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bunker, S.R.; Kolina, J.S.; Kaplan, K.A.

    1983-05-01

    Scintigraphy with RBCs labeled with technetium Tc 99m sodium pertechnetate effectively located the source of hemorrhage in a patient receiving long-term anticoagulant therapy. (The patient was initially seen with a large hematoma on the flank.) More important, the procedure was used to monitor activity in this otherwise-occult bleeding site. Scintigraphic studies may be useful in the management of these difficult clinical problems.

  4. 99mTc-EDDA/HYNIC-TOC in management of patients with head and neck somatostatin receptor positive tumors.

    PubMed

    Trogrlic, Mate; Tezak, Stanko

    2016-01-01

    Aim of this study was to determine the value of technetium-99m-hydrazinonicotinyl-Tyr3-octreotide (99mTc-ED-DA/HYNIC-TOC) in patients with somatostatin receptor (SSR) positive tumors of head and neck region. A total number of 16 patients were enrolled in this study. Planar whole body (WB) and single photon emission computed tomography (SPECT) images were acquired at 2 and 4 hours after the injection of approximately 670 MBq of 99mTc-EDDA/HYNIC-TOC. Additional single photon emission computed tomography/computed tomography (SPECT/CT) images of the head and neck region were acquired at 4h post tracer injection. Clinical and imaging follow up were taken as the reference standard. There were 10 female and 6 male patients of age 57.7 ± 12.9 years (58.5; 32-78) years. 99mTc-EDDA/HYNIC-TOC somatostatin receptor scintigraphy (SRS) was TP in 13 patients, TN in two and FP in one. Follow up period for SRS was 31.1 ± 19.4 (29; 2-63) months. 99mTc-EDDA/HYNIC-TOC scintigraphy provided additional information in 50% of patients, with impact on patient management in the same percentage of patients. Distant metastases were found in nine out of 16 patients (56%). 99mTc-EDDA/HYNIC-TOC SRS had sensitivity of 100% (75.3-100%), specificity of 66.7% (9.4-99.2%), accuracy of 93.7%, positive predictive value of 92.9% (66.1-99.8%), and negative predictive value of 100% (15.8-100%). Somatostatin receptor scintigraphy using 99mTc-EDDA/HYNIC-TOC is very useful imaging method in the evalu-ation of patients with SSR positive tumors of head and neck region.

  5. Comparison of technetium-99m-HM-PAO leukocytes with indium-111-oxine leukocytes for localizing intraabdominal sepsis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mountford, P.J.; Kettle, A.G.; O'Doherty, M.J.

    Technetium-99m-HM-PAO (({sup 99m}Tc)HM-PAO) leukocyte and indium-111-oxine (111In-oxine) leukocyte scanning were carried out simultaneously in 41 patients at 4 hr and 24 hr after reinjection to determine whether the 4-hr {sup 99m}Tc scan could replace the 24-hr {sup 111}In scan for detecting intraabdominal sepsis. Abdominal infection was confirmed in 12 cases. The 4-hr {sup 99}Tc-leukocyte scan, the 4-hr {sup 111}In-leukocyte scan, and the 24-hr {sup 111}In-leukocyte scan yielded a sensitivity of 100%, 67%, and 100%, respectively, and a specificity of 62%, 90%, and 86%, respectively. The 24-hr {sup 99m}Tc-leukocyte scan also produced a sensitivity of 100%, but it was falsely positivemore » in all 29 cases without infection due to physiologic bowel uptake. False-positive 4-hr {sup 99m}Tc-leukocyte scans were also produced by physiologic bowel uptake in seven cases all of whom had true-negative 4-hr and 24-hr {sup 111}In-leukocyte scans. Because of the high incidence of false-positive 4-hr ({sup 99m}Tc)HM-PAO leukocyte scans, it was concluded that they could not replace 24-hr {sup 111}In-leukocyte scans for detecting intraabdominal sepsis, and that serial {sup 99m}Tc leukocyte scans starting earlier than 4 hr after reinjection must be evaluated.« less

  6. Normal regional distribution of cerebral blood flow in dogs: comparison between (99m) Tc-ethylcysteinate dimer and (99m) Tc- hexamethylpropylene amine oxime single photon emission computed tomography.

    PubMed

    Adriaens, Antita; Polis, Ingeborgh; Waelbers, Tim; Vandermeulen, Eva; Dobbeleir, André; De Spiegeleer, Bart; Peremans, Kathelijne

    2013-01-01

    Functional imaging provides important insights into canine brain pathologies such as behavioral problems. Two (99m) Tc-labeled single photon emission computed tomography (SPECT) cerebral blood flow tracers-ethylcysteinate dimer (ECD) and hexamethylpropylene amine oxime (HMPAO)-are commonly used in human medicine and have been used previously in dogs but intrasubject comparison of both tracers in dogs is lacking. Therefore, this study investigated whether regional distribution differences between both tracers occur in dogs as is reported in humans. Eight beagles underwent two SPECT examinations first with (99m) Tc-ECD and followed by (99m) Tc-HMPAO. SPECT scanning was performed with a triple head gamma camera equipped with ultrahigh resolution parallel hole collimators. Images were reconstructed using filtered backprojection with a Butterworth filter. Emission data were fitted to a template permitting semiquantification using predefined regions or volumes of interest (VOIs). For each VOI, perfusion indices were calculated by normalizing the regional counts per voxel to total brain counts per voxel. The obtained perfusion indices for each region for both tracers were compared with a paired Student's T-test. Significant (P < 0.05) regional differences were seen in the subcortical region and the cerebellum. Both tracers can be used to visualize regional cerebral blood flow in dogs, however, due to the observed regional differences, they are not entirely interchangeable. © 2013 Veterinary Radiology & Ultrasound.

  7. Value of positive myocardial technetium-99m-pyrophosphate scintigraphy in the noninvasive diagnosis of cardiac amyloidosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wizenberg, T.A.; Muz, J.; Sohn, Y.H.

    1982-04-01

    Ten consecutive patients with tissue-proven amyloidosis, seven of whom presented with congestive heart failure, were found to exhibit intense diffuse uptake of technetium-99m-pyrophosphate (Tc-99m-PYP) on cardiac radionuclide imaging. The patients exhibited echocardiographic and systolic time interval abnormalities suggesting combined restrictive and congestive cardiomyopathic changes. On M-mode echocardiograms, there was symmetrically increased thickness of the interventricular septum and left ventricular (LV) posterior wall in diastole (10 of 10), decreased fractional shortening of the LV minor axis diameter in systole (eight of nine), and decreased percent thickening of the LV minor axis diameter in systole (eight of nine) and LV posterior wallmore » (10 of 10) in systole. Three patients demonstrated enlarged LV end-diastolic diameter. All 10 patients had abnormal PEP/LVET and eight had shortened LVETI. When combined with noninvasive tests of LV performance, positive myocardial pyrophosphate (PYP) scanning provides a new and useful adjunct in the diagnosis of amyloid heart disease.« less

  8. Amyloidosis of heart and liver: comparison of Tc-99m pyrophosphate and Tc-99m methylene diphosphonate for detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, V.W.; Caldarone, A.G.; Falk, R.H.

    1983-07-01

    A prospective, comparative study was made of the efficacy of technetium-99m pyrophosphate (Tc PYP) and technetium-99m methylene diphosphonate (Tc MDP) in detecting soft-tissue amyloidois. Tc PYP and Tc MDP scans were obtained within ten-day intervals in seven patients with histologically proven amyloidosis. Tc PYP was a better scanning agent for soft-tissue amyloidosis in all patients. Cardiac and hepatic involvement were proved by autopsy in one patient. Involvement of the heart was confirmed by echocardiography in five patients. The potential use of tc PYP scannning as a screening test for soft-tissue amyloidosis is discussed.

  9. Factors affecting the sensitivity of Tc-99m methoxyisobutylisonitrile dual-phase parathyroid single photon emission computed tomography in primary hyperparathyroidism.

    PubMed

    Araz, Mine; Çayir, Derya; Erdoğan, Mehmet; Uçan, Bekir; Çakal, Erman

    2017-02-01

    The aim of this study was to investigate the effects of thyroid diseases and regularly used medications on the sensitivity of Tc-99m methoxyisobutylisonitrile (MIBI) dual-phase parathyroid single photon emission computed tomography (SPECT) and to define indicatives of the result of the study. Overall, 218 primary hyperparathyroidism patients (190 women, 28 men, mean age: 57±14 years) with thyroid-parathyroid ultrasonography and Tc-99m MIBI dual-phase parathyroid SPECT were retrospectively enrolled. Patients were divided as follows: a positive SPECT group [119 (54.6%) patients] and a negative SPECT group [99 (45.4%) patients]. The effects of thyroid diseases and use of calcium channel blockers, β-blockers, angiotensin-converting enzyme inhibitors/angiotensin receptor blockers, oral antidiabetics, thyroid hormone preparates, nonsteroidal anti-inflammatory drugs, and proton pump inhibitors on the sensitivity of Tc-99m MIBI dual-phase parathyroid SPECT were investigated. The frequency of NSAID usage was higher in the negative scan group (P<0.001). No significant difference was detected in terms of coexisting thyroid disease or usage of other medications. Overall sensitivity, specificity, positive, and negative predictive value of Tc-99m MIBI dual-phase parathyroid SPECT were calculated to be 89.6, 92.5, 94.1, and 86.9%. The sensitivity was low only in nonsteroidal anti-inflammatory drug users (75.6%) compared with nonusers (96.5%). Logistic regression showed that ultrasonography was indicative of a positive scan and the possibility of a negative result was increased by regular usage of nonsteroid anti-inflammatory drugs (odds ratio: 0.262, confidence interval: 0.128-0.538; P<0.001) CONCLUSION: Among various drug groups, NSAIDs may decrease the sensitivity of Tc-99m MIBI SPECT and, provided that these novel data are supported by other studies, patient preparation may be modified to stop NSAIDs before Tc-99m MIBI dual-phase parathyroid SPECT.

  10. Development of (99m)Tc-labeled asymmetric urea derivatives that target prostate-specific membrane antigen for single-photon emission computed tomography imaging.

    PubMed

    Kimura, Hiroyuki; Sampei, Sotaro; Matsuoka, Daiko; Harada, Naoya; Watanabe, Hiroyuki; Arimitsu, Kenji; Ono, Masahiro; Saji, Hideo

    2016-05-15

    Prostate-specific membrane antigen (PSMA) is expressed strongly in prostate cancers and is, therefore, an attractive diagnostic and radioimmunotherapeutic target. In contrast to previous reports of PMSA-targeting (99m)Tc-tricarbonyl complexes that are cationic or lack a charge, no anionic (99m)Tc-tricarbonyl complexes have been reported. Notably, the hydrophilicity conferred by both cationic and anionic charges leads to rapid hepatobiliary clearance, whereas an anionic charge might better enhance renal clearance relative to a cationic charge. Therefore, an improvement in rapid clearance would be expected with either cationic or anionic charges, particularly anionic charges. In this study, we designed and synthesized a novel anionic (99m)Tc-tricarbonyl complex ([(99m)Tc]TMCE) and evaluated its use as a single-photon emission computed tomography (SPECT) imaging probe for PSMA detection. Direct synthesis of [(99m)Tc]TMCE from dimethyl iminodiacetate, which contains both the asymmetric urea and succinimidyl moiety important for PSMA binding, was performed using our microwave-assisted one-pot procedure. The chelate formation was successfully achieved even though the precursor included a complicated bioactive moiety. The radiochemical yield of [(99m)Tc]TMCE was 12-17%, with a radiochemical purity greater than 98% after HPLC purification. [(99m)Tc]TMCE showed high affinity in vitro, with high accumulation in LNCaP tumors and low hepatic retention in biodistribution and SPECT/CT studies. These findings warrant further evaluation of [(99m)Tc]TMCE as an imaging agent and support the benefit of this strategy for the design of other PSMA imaging probes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. A modified TEW approach to scatter correction for In-111 and Tc-99m dual-isotope small-animal SPECT.

    PubMed

    Prior, Paul; Timmins, Rachel; Petryk, Julia; Strydhorst, Jared; Duan, Yin; Wei, Lihui; Glenn Wells, R

    2016-10-01

    In dual-isotope (Tc-99m/In-111) small-animal single-photon emission computed tomography (SPECT), quantitative accuracy of Tc-99m activity measurements is degraded due to the detection of Compton-scattered photons in the Tc-99m photopeak window, which originate from the In-111 emissions (cross talk) and from the Tc-99m emission (self-scatter). The standard triple-energy window (TEW) estimates the total scatter (self-scatter and cross talk) using one scatter window on either side of the Tc-99m photopeak window, but the estimate is biased due to the presence of unscattered photons in the scatter windows. The authors present a modified TEW method to correct for total scatter that compensates for this bias and evaluate the method in phantoms and in vivo. The number of unscattered Tc-99m and In-111 photons present in each scatter-window projection is estimated based on the number of photons detected in the photopeak of each isotope, using the isotope-dependent energy resolution of the detector. The camera-head-specific energy resolutions for the 140 keV Tc-99m and 171 keV In-111 emissions were determined experimentally by separately sampling the energy spectra of each isotope. Each sampled spectrum was fit with a Linear + Gaussian function. The fitted Gaussian functions were integrated across each energy window to determine the proportion of unscattered photons from each emission detected in the scatter windows. The method was first tested and compared to the standard TEW in phantoms containing Tc-99m:In-111 activity ratios between 0.15 and 6.90. True activities were determined using a dose calibrator, and SPECT activities were estimated from CT-attenuation-corrected images with and without scatter-correction. The method was then tested in vivo in six rats using In-111-liposome and Tc-99m-tetrofosmin to generate cross talk in the area of the myocardium. The myocardium was manually segmented using the SPECT and CT images, and partial-volume correction was performed using

  12. Use of quantitative SPECT/CT reconstruction in 99mTc-sestamibi imaging of patients with renal masses.

    PubMed

    Jones, Krystyna M; Solnes, Lilja B; Rowe, Steven P; Gorin, Michael A; Sheikhbahaei, Sara; Fung, George; Frey, Eric C; Allaf, Mohamad E; Du, Yong; Javadi, Mehrbod S

    2018-02-01

    Technetium-99m ( 99m Tc)-sestamibi single-photon emission computed tomography/computed tomography (SPECT/CT) has previously been shown to allow for the accurate differentiation of benign renal oncocytomas and hybrid oncocytic/chromophobe tumors (HOCTs) apart from other malignant renal tumor histologies, with oncocytomas/HOCTs showing high uptake and renal cell carcinoma (RCC) showing low uptake based on uptake ratios from non-quantitative single-photon emission computed tomography (SPECT) reconstructions. However, in this study, several tumors fell close to the uptake ratio cutoff, likely due to limitations in conventional SPECT/CT reconstruction methods. We hypothesized that application of quantitative SPECT/CT (QSPECT) reconstruction methods developed by our group would provide more robust separation of hot and cold lesions, serving as an imaging framework on which quantitative biomarkers can be validated for evaluation of renal masses with 99m Tc-sestamibi. Single-photon emission computed tomography data were reconstructed using the clinical Flash 3D reconstruction and QSPECT methods. Two blinded readers then characterized each tumor as hot or cold. Semi-quantitative uptake ratios were calculated by dividing lesion activity by background renal activity for both Flash 3D and QSPECT reconstructions. The difference between median (mean) hot and cold tumor uptake ratios measured 0.655 (0.73) with the QSPECT method and 0.624 (0.67) with the conventional method, resulting in increased separation between hot and cold tumors. Sub-analysis of 7 lesions near the separation point showed a higher absolute difference (0.16) between QPSECT and Flash 3D mean uptake ratios compared to the remaining lesions. Our finding of improved separation between uptake ratios of hot and cold lesions using QSPECT reconstruction lays the foundation for additional quantitative SPECT techniques such as SPECT-UV in the setting of renal 99m Tc-sestamibi and other SPECT/CT exams. With robust

  13. p-Tertbutylcalix[4]arene nanoemulsion: preparation, characterization and comparative evaluation of its decontamination efficacy against Technetium-99m, Iodine-131 and Thallium-201.

    PubMed

    Rana, Sudha; Sharma, Navneet; Ojha, Himanshu; Shivkumar, Hosakote Gurumalappa; Sultana, Sarwat; Sharma, Rakesh Kumar

    2014-05-01

    This study aimed to develop p-tertbutylcalix[4]arene o/w nanoemulsion for decontamination of radioisotopes from skin. Formulation was characterized using dynamic light scattering (DLS), transmission electron microscopy (TEM), multi-photon confocal microscopy techniques and in vitro dissolution studies. In vivo evaluation of nano-emulsion was done using nuclear medicine technique. Stability studies and dermal toxicity studies were also carried out. Comparative decontamination efficacy (DE) studies were performed on synthetic human tissue equivalent material and Sprague Dawley rat against three commonly used medical radioisotopes, i.e., Technetium-99m ((99m)Tc), Iodine-131 ((131)I) and Thallium-201 ((201)Tl). Decontamination was performed using cotton swabs soaked in nanoemulsion at different time intervals of contaminants exposure. Whole body imaging and static counts were recorded using gamma camera before and after each decontamination attempt data was analyzed using one way analysis of variance (ANOVA) and found to be statistically significant (p<0.05). DE of the nanoemulsion loaded with p-tertbutylcalix[4]arene was observed to be 88±5%, 90±3% and 89±3% for (99m)Tc, (131)I and (201)Tl respectively. Dermal toxicity studies revealed no significant differences between treated and control animals. Skin histopathology slides with and without API (Active pharmaceutical ingredients) also found to be comparable. p-Tertbutylcalix[4]arene loaded nanoemulsion shows great promise for skin decontamination against broad ranges of radiological contaminants besides being stable and safe. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Importance of methodology on (99m)technetium dimercapto-succinic acid scintigraphic image quality: imaging pilot study for RIVUR (Randomized Intervention for Children With Vesicoureteral Reflux) multicenter investigation.

    PubMed

    Ziessman, Harvey A; Majd, Massoud

    2009-07-01

    We reviewed our experience with (99m)technetium dimercapto-succinic acid scintigraphy obtained during an imaging pilot study for a multicenter investigation (Randomized Intervention for Children With Vesicoureteral Reflux) of the effectiveness of daily antimicrobial prophylaxis for preventing recurrent urinary tract infection and renal scarring. We analyzed imaging methodology and its relation to diagnostic image quality. (99m)Technetium dimercapto-succinic acid imaging guidelines were provided to participating sites. High-resolution planar imaging with parallel hole or pinhole collimation was required. Two core reviewers evaluated all submitted images. Analysis included appropriate views, presence or lack of patient motion, adequate magnification, sufficient counts and diagnostic image quality. Inter-reader agreement was evaluated. We evaluated 70, (99m)technetium dimercapto-succinic acid studies from 14 institutions. Variability was noted in methodology and image quality. Correlation (r value) between dose administered and patient age was 0.780. For parallel hole collimator imaging good correlation was noted between activity administered and counts (r = 0.800). For pinhole imaging the correlation was poor (r = 0.110). A total of 10 studies (17%) were rejected for quality issues of motion, kidney overlap, inadequate magnification, inadequate counts and poor quality images. The submitting institution was informed and provided with recommendations for improving quality, and resubmission of another study was required. Only 4 studies (6%) were judged differently by the 2 reviewers, and the differences were minor. Methodology and image quality for (99m)technetium dimercapto-succinic acid scintigraphy varied more than expected between institutions. The most common reason for poor image quality was inadequate count acquisition with insufficient attention to the tradeoff between administered dose, length of image acquisition, start time of imaging and resulting image

  15. Detection of occult pericardial hemorrhage early after open-heart surgery using technetium-99m red blood cell radionuclide ventriculography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bateman, T.M.; Czer, L.S.; Gray, R.J.

    1984-11-01

    Pericardial or mediastinal hemorrhage requiring reoperation occurs in 2% to 5% of patients, usually early (0 to 48 hours), after open-heart surgery. This hemorrhage may be occult, and resulting cardiac tamponade may easily be misinterpreted as ventricular dysfunction, common early postoperatively. In such cases, appropriate and timely intervention may not occur. Of 50 patients evaluated by technetium-99m red blood cell gated equilibrium radionuclide ventriculography (RNV) because of early postoperative cardiogenic shock of uncertain etiology, 17 had unique scintigraphic images suggestive of intrathoracic hemorrhage. Of these 17, 5 had a generalized halo of abnormal radioactivity surrounding small hyperdynamic right and leftmore » ventricles, 11 had localized regions of intense blood pool activity outside the cardiac chambers (two with compression of single chambers), and one demonstrated marked radionuclide activity in the right hemithorax (2000 ml of blood at reoperation). Twelve patients had exploratory reoperation for control of hemorrhage as a direct result of the scintigraphic findings, three were successfully treated with fresh frozen plasma and platelet infusions along with medical interventions to optimize cardiac performance, and two patients died in cardiogenic shock (presumed tamponade) without reoperation. In the 12 reoperated patients, all were confirmed to have active pericardial bleeding. Scintigraphic localization of abnormal blood pools within the pericardium corresponded to the sites at which active bleeding was witnessed at reoperation. The abnormal bleeding was etiologically related to the tamponade state, with marked improvement in hemodynamics after reoperation. Nine additional patients were reoperated for presumed tamponade after RNV revealed an exaggerated halo of photon deficiency surrounding the cardiac chambers.« less

  16. Technetium-99m thyroid scan; does it have a diagnostic aid in sub-clinical auto-immune thyroid disease in systemic lupus erythematosus patients?

    PubMed

    Amin, A; Alkemary, A; Abdo, M; Salama, M

    2016-02-01

    Technetium-99m (Tc-99m) thyroid scintigraphy is a well known diagnostic tool that shows the entire gland in a single image. We aimed to evaluate its additive diagnostic value in subclinical autoimmune thyroid disease (S-AITD) in systemic lupus erythematosus (SLE) patients. We investigated 100 systemic lupus erythematosus (SLE) patients without overt thyroid involvement (eight men and 92 women; mean age 40±6.5 years) and 50 age and sex matched controls. All were subjected to thyroid evaluation using anti-thyroglobulin (anti-TG) and anti-thyroid peroxidase (anti-TPO) antibodies; hormones (FT3; FT4 and TSH) and Tc-99m thyroid scintigraphy. 14/100 (14%) and none (0%) were positive for S-AITD in SLE and control groups, respectively (P = 0.0001). They were classified by thyroid scintigraphy and hormonal profile into 2/14 Hashimoto; 10/14 atrophic thyroiditis and 2/14 Graves' disease. Anti-TPO was elevated in 12 SLE cases, while anti-TG was elevated in only 2/14 (P = 0.0001). Thyroid scintigraphy showed statistically significant associations with FT4, TSH and anti-TPO. Tc-99m thyroid scintigraphy may have an additional diagnostic role in S-AITD among SLE patients, with an impact on patient management. This potential needs to be further evaluated in a larger series on a multicenter basis. © The Author(s) 2015.

  17. Structural characterization of a bridged 99Tc-Sn-dimethylglyoxime complex: implications for the chemistry of 99mTc-radiopharmaceuticals prepared by the Sn (II) reduction of pertechnetate.

    PubMed Central

    Deutsch, E; Elder, R C; Lange, B A; Vaal, M J; Lay, D G

    1976-01-01

    Reduction of pertechnetate by tin(II) in the presence of dimethylglyoxime is shown, by single crystal x-ray analysis, to yield a technetium-tin-dimethylglyoxime complex in which tin and technetium are intimately connected by a triple bridging arrangement. One bridge consists of a single oxygen atom and it is hypothesized that this bridge arises from the inner sphere reduction of technetium by tin(II), the electrons being transferred through a technetium "yl" oxygen which eventually becomes the bridging atom. Two additional bridges arise from two dimethylglyoxime ligands that function as bidentate nitrogen donors towards Tc and monodentate oxygen donors towards Sn. The tin atom can thus be viewed as providing a three-pronged "cap" on one end of the Tc-dimethylglyoxime complex. The additional coordination sites around Tc are occupied by the two nitrogens of a third dimethylglyoxime ligand, making the Tc seven-coordinate. The additional coordination sites around Sn are occupied by three chloride anions, giving the Sn a fac octahedral coordination environment. From indirect evidence the oxidation states of tin and technetium are tentatively assigned to be IV and V, respectively. Since most 99mTc-radiopharmaceuticals are synthesized by the tin(II) reduction of pertechnetate, it is likely that the Sn-O-Tc linkage described in this work is an important feature of the chemistry of these species. This linkage also provides a ready rationale for the close association of tin and technetium observed in many 99mTc-radiopharmaceuticals. PMID:1069984

  18. The role of technetium-99m stannous pyrophosphate in myocardial imaging to recognize, localize and identify extension of acute myocardial infarction in patients

    NASA Technical Reports Server (NTRS)

    Willerson, J. T.; Parkey, R. W.; Bonte, F. J.; Stokely, E. M.; Buja, E. M.

    1975-01-01

    The ability of technetium-99m stannous pyrophosphate myocardial scintigrams to aid diagnostically in recognizing, localizing, and identifying extension of acute myocardial infarction in patients was evaluated. The present study is an extension of previous animal and patient evaluations that were recently performed utilizing this myocardial imaging agent.

  19. Deterministic and robust generation of single photons from a single quantum dot with 99.5% indistinguishability using adiabatic rapid passage.

    PubMed

    Wei, Yu-Jia; He, Yu-Ming; Chen, Ming-Cheng; Hu, Yi-Nan; He, Yu; Wu, Dian; Schneider, Christian; Kamp, Martin; Höfling, Sven; Lu, Chao-Yang; Pan, Jian-Wei

    2014-11-12

    Single photons are attractive candidates of quantum bits (qubits) for quantum computation and are the best messengers in quantum networks. Future scalable, fault-tolerant photonic quantum technologies demand both stringently high levels of photon indistinguishability and generation efficiency. Here, we demonstrate deterministic and robust generation of pulsed resonance fluorescence single photons from a single semiconductor quantum dot using adiabatic rapid passage, a method robust against fluctuation of driving pulse area and dipole moments of solid-state emitters. The emitted photons are background-free, have a vanishing two-photon emission probability of 0.3% and a raw (corrected) two-photon Hong-Ou-Mandel interference visibility of 97.9% (99.5%), reaching a precision that places single photons at the threshold for fault-tolerant surface-code quantum computing. This single-photon source can be readily scaled up to multiphoton entanglement and used for quantum metrology, boson sampling, and linear optical quantum computing.

  20. Eosinophilic enterocolitis diagnosed by means of technetium-99m albumin scintigraphy and treated with budesonide (CIR).

    PubMed Central

    Russel, M G; Zeijen, R N; Brummer, R J; de Bruine, A P; van Kroonenburgh, M J; Stockbrügger, R W

    1994-01-01

    A patient with a 15 year history of diarrhoea of unknown origin is described. Scintigraphy with technetium-99m labelled albumin suggested albumin loss at the terminal ileum and caecum; subsequent colonoscopic biopsies of these macroscopically normal looking areas showed abundant infiltration with eosinophils. A diagnosis of eosinophilic enterocolitis was made. Treatment with prednisolone had good results, but had to be stopped because of severe side effects. Oral cromoglycate and mesalazine were not effective. Budesonide (CIR), a new topically active corticosteroid with very little systemic effects, was at least as effective as prednisolone without producing side effects. Images Figure 1 Figure 2 Figure 3 Figure 4 PMID:7959211

  1. Measurement of translymphatic fluid absorption using technetium-99m human serum albumin diethylenetriamine pentaacetic acid in continuous ambulatory peritoneal dialysis patients.

    PubMed

    Terawaki, Hiroyuki; Nakayama, Masaaki; Seto, Kazuhiko; Yoshimura, Kazunobu; Hasegawa, Toshio

    2004-08-01

    We have established a new method of measuring translymphatic fluid absorption (TLA) using technetium-99m ((99m)Tc) human serum albumin diethylenetriamine pentaacetic acid ((99m)Tc-HSAD) that can be used commonly in clinical practice. This new method was applied in 13 continuous ambulatory peritoneal dialysis patients (11 males and two females) who had various peritoneal permeability and capacities for peritoneal transport of water. (99m)Tc-HSAD 740MBq was injected in 2 L of peritoneal dialysis fluid with 2.5% glucose, mixed well, and administered intraperitoneally. The fluid was drained extraperitoneally after 4 h and TLA was determined by the in vivo loss of (99m)Tc-HSAD. TLA was 1.41 +/- 1.11 mL/min (mean +/- SD; range, 0.27-3.69 mL/min). The estimated reduction rate by TLA in trans-peritoneally removed fluid ranged from 14.2 to 84.4%, indicating that TLA could have an extremely significant negative effect in some cases on total drainage volume. The present study, using new tracer (99m)Tc-HSAD, could confirm a large individual difference in TLA, indicating TLA as an important contributing factor for fluid-removal failure in continuous ambulatory peritoneal dialysis patients.

  2. Effect of Thuya occidentalis on the labeling of red blood cells and plasma proteins with technetium-99m.

    PubMed Central

    Oliveira, J. F.; Braga, A. C.; Avila, A. S.; Fonseca, L. M.; Gutfilen, B.; Bernardo-Filho, M.

    1996-01-01

    Thuya occidentalis is used in popular medicine in the treatment of condyloma and has antibacterial action. Red blood cells (RBC) labeled with technetium-99m (99mTc) are used for several evaluations in nuclear medicine. This labeling depends on a reducing agent, usually stannous ion. Any drug which alters the labeling of the tracer could be expected to modify the disposition of the radiopharmaceutical. We have evaluated the influence of T. occidentalis extract on the labeling of RBC and plasma proteins with 99mTc. Blood was withdrawn and incubated with T. occidentalis (0.25; 2.5; 20.5; and 34.1 percent v/v). Stannous chloride (1.2 micrograms/ml) was added and then 99mTc was added. Plasma (P) and blood cells (BC) were isolated, also precipitated with trichloroacetic acid and soluble (SF) and insoluble fractions (IF) separated. The analysis of the results shows that there is a decrease in radioactivity (from 97.64 to 75.89 percent) in BC with 34.1 percent of the drug. In the labeling process of RBC with 99mTc, the stannous and pertechnetate ions pass through the membrane, so we suggest that the T. occidentalis effect can be explained (i) by an inhibition of the transport of these ions, (ii) by damage in membrane, (iii) by competition with the cited ions for the same binding sites, or (iv) by possible generation of reactive oxygen species that could oxidize the stannous ion. PMID:9436292

  3. Effect of Thuya occidentalis on the labeling of red blood cells and plasma proteins with technetium-99m.

    PubMed

    Oliveira, J F; Braga, A C; Avila, A S; Fonseca, L M; Gutfilen, B; Bernardo-Filho, M

    1996-01-01

    Thuya occidentalis is used in popular medicine in the treatment of condyloma and has antibacterial action. Red blood cells (RBC) labeled with technetium-99m (99mTc) are used for several evaluations in nuclear medicine. This labeling depends on a reducing agent, usually stannous ion. Any drug which alters the labeling of the tracer could be expected to modify the disposition of the radiopharmaceutical. We have evaluated the influence of T. occidentalis extract on the labeling of RBC and plasma proteins with 99mTc. Blood was withdrawn and incubated with T. occidentalis (0.25; 2.5; 20.5; and 34.1 percent v/v). Stannous chloride (1.2 micrograms/ml) was added and then 99mTc was added. Plasma (P) and blood cells (BC) were isolated, also precipitated with trichloroacetic acid and soluble (SF) and insoluble fractions (IF) separated. The analysis of the results shows that there is a decrease in radioactivity (from 97.64 to 75.89 percent) in BC with 34.1 percent of the drug. In the labeling process of RBC with 99mTc, the stannous and pertechnetate ions pass through the membrane, so we suggest that the T. occidentalis effect can be explained (i) by an inhibition of the transport of these ions, (ii) by damage in membrane, (iii) by competition with the cited ions for the same binding sites, or (iv) by possible generation of reactive oxygen species that could oxidize the stannous ion.

  4. Determination of technetium-99 in environmental samples: a review.

    PubMed

    Shi, Keliang; Hou, Xiaolin; Roos, Per; Wu, Wangsuo

    2012-01-04

    Due to the lack of a stable technetium isotope, and the high mobility and long half-life, (99)Tc is considered to be one of the most important radionuclides in safety assessment of environmental radioactivity as well as nuclear waste management. (99)Tc is also an important tracer for oceanographic research due to the high technetium solubility in seawater as TcO(4)(-). A number of analytical methods, using chemical separation combined with radiometric and mass spectrometric measurement techniques, have been developed over the past decades for determination of (99)Tc in different environmental samples. This article summarizes and compares recently reported chemical separation procedures and measurement methods for determination of (99)Tc. Due to the extremely low concentration of (99)Tc in environmental samples, the sample preparation, pre-concentration, chemical separation and purification for removal of the interferences for detection of (99)Tc are the most important issues governing the accurate determination of (99)Tc. These aspects are discussed in detail in this article. Meanwhile, the different measurement techniques for (99)Tc are also compared with respect to advantages and drawbacks. Novel automated analytical methods for rapid determination of (99)Tc using solid extraction or ion exchange chromatography for separation of (99)Tc, employing flow injection or sequential injection approaches are also discussed. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. Regional cerebral blood flow assessed by single photon emission computed tomography (SPECT) in dogs with congenital portosystemic shunt and hepatic encephalopathy.

    PubMed

    Or, Matan; Peremans, Kathelijne; Martlé, Valentine; Vandermeulen, Eva; Bosmans, Tim; Devriendt, Nausikaa; de Rooster, Hilde

    2017-02-01

    Regional cerebral blood flow (rCBF) in eight dogs with congenital portosystemic shunt (PSS) and hepatic encephalopathy (HE) was compared with rCBF in eight healthy control dogs using single photon emission computed tomography (SPECT) with a 99m technetium-hexamethylpropylene amine oxime ( 99m Tc-HMPAO) tracer. SPECT scans were abnormal in all PSS dogs. Compared to the control group, rCBF in PSS dogs was significantly decreased in the temporal lobes and increased in the subcortical (thalamic and striatal) area. Brain perfusion imaging alterations observed in the dogs with PSS and HE are similar to those in human patients with HE. These findings suggest that dogs with HE and PSS have altered perfusion of mainly the subcortical and the temporal regions of the brain. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Measurement of technetium-99 in Marshall Islands soil samples by ICP-MS

    PubMed

    Tagami; Uchida; Hamilton; Robison

    2000-07-01

    Extraction techniques for recovery of technetium-99 (99Tc) for Inductively Coupled Plasma Mass Spectrometry (ICP-MS) measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (MI) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for 99Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the 99Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The 99Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq g(-1) dry weight (dw). The limit of detection for 99Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq g(-1) dw under standard operating conditions.

  7. TC-99m MIBI SPECT imaging in patients with lung carcinoma: is it a functional probe of multidrug resistance genes?

    PubMed

    Ak, Ilknur; Gülbaş, Zafer; Ocak, Suna; Kaya, Eser; Alataş, Füsun; Vardareli, Erkan; Metintaş, Muzaffer

    2007-01-01

    Multidrug-resistance (MDR) phenotype concerns altered membrane transport that results in lower cell concentrations of cytotoxic drug in many cancer types, including lung cancer, and is related to the overexpression of a variety of proteins that act as adenosine triphosphate-dependent extrusion pumps. Tc-99m Sestamibi (MIBI) is a transport substrate for P-glycoprotein (Pgp) pump. In this study, we assessed the uptake and clearance of technetium-99m-2-hexakis 2-methoxyisobutylisonitrile (Tc-99m MIBI) from the tumor and its correlation with messenger RNA (mRNA) levels of Pgp, MDR-associated protein (MRP1), and lung resistance protein (LRP) in lung carcinoma. This study was carried out on 19 patients (mean age, 60.1 +/- 2.07 years) with advanced-stage lung carcinoma. The tumor samples obtained by bronchoscopy were assessed to estimate the levels of Pgp, MRP1, and LRP expression on mRNA level by quantitative real-time reverse-transcription polymerase chain reaction. Tc-99m MIBI chest imaging was performed 15 and 180 minutes after injection of 740 MBq Tc-99m MIBI. The early (T/Be) and delayed (T/Bd) Tc-99m MIBI uptakes and washout rate (WR) of Tc-99m MIBI from the tumor were measured. No correlation was found between the T/Be Tc-99m MIBI uptake of tumors (T/Be) and the levels of Pgp mRNA, MRP1 mRNA, and LRP mRNA by reverse-transcription polymerase chain reaction. There was a correlation between the mean T/Bd Tc-99m MIBI uptake and Pgp expression of the tumors (P = 0.001, Spearman rho = - 0.702). There was a correlation between the WR of Tc-99m MIBI from the tumor and Pgp expression of the tumor (P = 0.000, Spearman rho = 0.875). Washout rate of Tc-99m MIBI was not related to the levels of MRP1 mRNA (P = 0.93, Spearman rho = 0.02) or LRP mRNA (P = 0.47, Spearman rho = 0.177). Increased WR of Tc-99m MIBI is related in Pgp over expression of the tumor. Tc-99m MIBI single photon emission computed tomography imaging may be a functional probe of overexpression of Pgp in

  8. PLA-PEG nanocapsules radiolabeled with 99mTechnetium-HMPAO: release properties and physicochemical characterization by atomic force microscopy and photon correlation spectroscopy.

    PubMed

    Pereira, Maira Alves; Mosqueira, Vanessa Carla Furtado; Vilela, José Mário Carneiro; Andrade, Margareth Spangler; Ramaldes, Gilson Andrade; Cardoso, Valbert Nascimento

    2008-01-01

    The present work describes the preparation, characterization and labelling of conventional and surface-modified nanocapsules (NC) with 99m Tc-HMPAO. The size, size distribution and homogeneity were determined by photon correlation spectroscopy (PCS) and zeta potential by laser doppler anemometry. The morphology and the structural organization were evaluated by atomic force microscopy (AFM). The stability and release profile of the NC were determined in vitro in plasma. The results showed that the use of methylene blue induces significant increase in the encapsulation efficiency of 99m Tc-HMPAO, from 24.4 to 49.8% in PLA NC and 22.37 to 52.93% in the case of PLA-PEG NC (P<0.05) by improving the complex stabilization. The average diameter of NC calculated by PCS varied from 216 to 323 nm, while the average diameter determined by AFM varied from 238 to 426 nm. The AFM analysis of diameter/height ratios suggested a greater homogeneity of the surface-modified PLA-PEG nanocapsules compared to PLA NC concerning their flattening properties. The in vitro release of the 99m Tc-HMPAO in plasma medium was faster for the conventional PLA NC than for the surface-modified NC. For the latter, 60% of the radioactivity remained associated with NC, even after 12h of incubation. The results suggest that the surface-modified 99m Tc-HMPAO-PLA-PEG NC was more stable against label leakage in the presence of proteins and could present better performance as radiotracer in vivo.

  9. Significance of Technetium-99m Human Serum Albumin Diethylenetriamine Pentaacetic Acid Scintigraphy in Patients with Nephrotic Syndrome

    PubMed Central

    Takashima, Tsuyoshi; Kishi, Tomoya; Onozawa, Koji; Rikitake, Shuichi; Miyazono, Motoaki; Otsuka, Takateru; Irie, Hiroyuki; Iwakiri, Ryuichi; Fujimoto, Kazuma; Ikeda, Yuji

    2015-01-01

    It is thought that a large amount of albumin leaking from the glomerulus in nephrotic syndrome (NS) is reabsorbed at the proximal tubule and catabolized. Therefore, it is possible the final quantity of urinary protein does not always reflect the amount of leakage of protein from the glomerulus. We experienced two cases without nephrotic range proteinuria thought to involve hypoproteinemia due to the same pathophysiology as NS. On these patients, we performed protein leakage scintigraphy with technetium-99m human serum albumin diethylenetriamine pentaacetic acid (99mTc-HSAD) to exclude a diagnosis of protein-losing gastroenteropathy and observed diffuse positive accumulation in the kidneys with more intense uptake in the kidney than the liver on the anterior view 24 hours after 99mTc-HSAD administration. In healthy adults intravenously given 99mTc-HSAD, the same dynamics are observed as in albumin metabolism, and the organ radioactivity of the liver and kidneys after 24 hours is equal. Therefore, we thought it was possible that the renal uptake 24 hours after 99mTc-HSAD administration was a characteristic finding of NS. In order to confirm it, the subjects were divided into two groups: the NS group (n = 10) and the non-NS group (n = 7). We defined more intense uptake in the kidney than the liver on the anterior view 24 hours after 99mTc-HSAD administration as Dense Kidney (+). Furthermore, we designed regions of interest in the right and left kidneys and liver on anterior and posterior images, then calculated the kidney-liver ratio. Nine of the ten patients had Dense Kidney (+) in the NS group, compared to none in the non-NS group. And the kidney-liver ratio was significantly higher in the NS group than in the non-NS group on each view in the bilateral kidneys. In conclusion, our results suggest that the renal uptake 24 hours after 99mTc-HSAD administration is a characteristic finding of NS. PMID:25859658

  10. Significance of technetium-99m human serum albumin diethylenetriamine pentaacetic acid scintigraphy in patients with nephrotic syndrome.

    PubMed

    Takashima, Tsuyoshi; Kishi, Tomoya; Onozawa, Koji; Rikitake, Shuichi; Miyazono, Motoaki; Otsuka, Takateru; Irie, Hiroyuki; Iwakiri, Ryuichi; Fujimoto, Kazuma; Ikeda, Yuji

    2015-01-01

    It is thought that a large amount of albumin leaking from the glomerulus in nephrotic syndrome (NS) is reabsorbed at the proximal tubule and catabolized. Therefore, it is possible the final quantity of urinary protein does not always reflect the amount of leakage of protein from the glomerulus. We experienced two cases without nephrotic range proteinuria thought to involve hypoproteinemia due to the same pathophysiology as NS. On these patients, we performed protein leakage scintigraphy with technetium-99m human serum albumin diethylenetriamine pentaacetic acid (99mTc-HSAD) to exclude a diagnosis of protein-losing gastroenteropathy and observed diffuse positive accumulation in the kidneys with more intense uptake in the kidney than the liver on the anterior view 24 hours after 99mTc-HSAD administration. In healthy adults intravenously given 99mTc-HSAD, the same dynamics are observed as in albumin metabolism, and the organ radioactivity of the liver and kidneys after 24 hours is equal. Therefore, we thought it was possible that the renal uptake 24 hours after 99mTc-HSAD administration was a characteristic finding of NS. In order to confirm it, the subjects were divided into two groups: the NS group (n = 10) and the non-NS group (n = 7). We defined more intense uptake in the kidney than the liver on the anterior view 24 hours after 99mTc-HSAD administration as Dense Kidney (+). Furthermore, we designed regions of interest in the right and left kidneys and liver on anterior and posterior images, then calculated the kidney-liver ratio. Nine of the ten patients had Dense Kidney (+) in the NS group, compared to none in the non-NS group. And the kidney-liver ratio was significantly higher in the NS group than in the non-NS group on each view in the bilateral kidneys. In conclusion, our results suggest that the renal uptake 24 hours after 99mTc-HSAD administration is a characteristic finding of NS.

  11. Identification of Hürthle cell tumor by single-injection, double-phase scintigraphy with technetium-99m-sestamibi.

    PubMed

    Vattimo, A; Bertelli, P; Cintorino, M; Burroni, L; Volterrani, D; Vella, A

    1995-05-01

    Early and late (double-phase) scintigraphy with 99mTc-MIBI was used in a comparative study of the scintigraphic aspects of Hürthle cell tumors and other thyroid tumors. Single-injection, dual-phase (15-30 min and 3-4 hr) thyroid scintigraphy with 99mTc-sestamibi (MIBI) was performed on 41 patients who displayed a cold nodule on previous 99mTc scintigraphy. Visual scoring of nodular uptake was done to compare thyroidal and background tracer uptake. In addition, the nodular-to-thyroid (N/T) uptake ratio in the early and late images and the washout rate from the nodule (WON) and thyroidal tissue (WOT) were measured. Cytologic results were obtained for all patients; histopathologic results were obtained for the 20 patients who had surgery. In eight patients (Group A), the nodule displayed intense and persistent uptake of MIBI (N/T = 1.77 +/- 0.46 and 3.20 +/- 1.37; WON = 17.2% +/- 6.3%; WOT = 24.6% +/- 7.5%); histopathology revealed Hürthle cell tumors (two carcinomas and three adenomas) in five surgical patients. In 15 patients (Group B), the nodule displayed intense uptake in the early image with fading activity in the late image (N/T = 1.45 +/- 0.54 and 0.84 +/- 0.30; WON = 30.0% +/- 7.3%; WOT = 24.5% +/- 6.8%); histopathology revealed a colloid nodule (n = 1), papillary carcinoma (n = 4) and follicular carcinoma (n = 5) in 10 surgical patients. In the remaining 18 patients (Group C), the nodule was cold and late images were not acquired. Histopathology revealed colloid nodules (n = 2) and follicular adenoma (n = 3) in five surgical patients. Single-injection, dual-phase MIBI scintigraphy of the thyroid can identify Hürthle cell tumors because these tumors have intense, persistent tracer uptake in contrast to other thyroid tumors.

  12. A novel Tc-99m and fluorescence labeled peptide as a multimodal imaging agent for targeting angiogenesis in a murine hindlimb ischemia model.

    PubMed

    Hyoun Kim, Myoung; Kim, Seul-Gi; Guhn Kim, Chang; Kim, Dae-Weung

    2017-03-01

    The serine-aspartic acid-valine (SDV) peptide binds specifically to integrin αvβ3. We developed a Tc-99m and TAMRA labeled peptide, Tc-99m SDV-ECG-K-TAMRA for multimodal imaging of angiogenesis. Tc-99m SDV-ECG-K-TAMRA was prepared in high yield (>96%) and showed low cytotoxicity. Tc-99m tetrofosmin images 1 week after operation, revealed significantly decreased perfusion of the ischemic hindlimb, and the perfusion recovered gradually for 4 weeks. In contrast, Tc-99m SDV-ECG-K-TAMRA uptake was maximal 1 week after the operation (ischemic-to-non-ischemic uptake ratio =5.03±1.01) and decreased gradually. The ischemic-to-non-ischemic ratio of Tc-99m SDV-ECG-K-TAMRA and Tc-99m tetrofosmin was strongly negatively correlated (r =-0.94). A postmortem analysis revealed increased angiogenesis markers and uptake of Tc-99m SDV-ECG-K-TAMRA by ischemic tissue. Our in vivo and in vitro studies revealed substantial uptake of Tc-99m SDV-ECG-K-TAMRA by ischemic tissue. Tc-99m SDV-ECG-K-TAMRA could be a good candidate dual-modality imaging agent to assess angiogenesis. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Imaging discordance between hepatic angiography versus Tc-99m-MAA SPECT/CT: a case series, technical discussion and clinical implications.

    PubMed

    Kao, Yung Hsiang; Tan, Eik Hock; Teo, Terence Kiat Beng; Ng, Chee Eng; Goh, Soon Whatt

    2011-11-01

    During pre-therapy evaluation for yttrium-90 (Y-90) radioembolization, it is uncommon to find severe imaging discordance between hepatic angiography versus technetium-99m-macroaggregated albumin (Tc-99m-MAA) single photon emission computed tomography with integrated low-dose CT (SPECT/CT). The reasons for severe imaging discordance are unclear, and literature is scarce. We describe 3 patients with severe imaging discordance, whereby tumor angiographic contrast hypervascularity was markedly mismatched to the corresponding Tc-99m-MAA SPECT/CT, and its clinical impact. The incidence of severe imaging discordance at our institution was 4% (3 of 74 cases). We postulate that imaging discordance could be due to a combination of 3 factors: (1) different injection rates between soluble contrast molecules versus Tc-99m-MAA; (2) different arterial flow hemodynamics between soluble contrast molecules versus Tc-99m-MAA; (3) eccentric release position of Tc-99m-MAA due to microcatheter tip location, inadvertently selecting non-target microparticle trajectories. Tc-99m-MAA SPECT/CT more accurately represents hepatic microparticle biodistribution than soluble contrast hepatic angiography and should be a key criterion in patient selection for Y-90 radioembolization. Tc-99m-MAA SPECT/CT provides more information than planar scintigraphy to guide radiation planning and clinical decision making. Severe imaging discordance at pre-therapy evaluation is ominous and should be followed up by changes to the final vascular approach during Y-90 radioembolization.

  14. 99mTechnetium-based Prostate-specific Membrane Antigen-radioguided Surgery in Recurrent Prostate Cancer.

    PubMed

    Maurer, Tobias; Robu, Stephanie; Schottelius, Margret; Schwamborn, Kristina; Rauscher, Isabel; van den Berg, Nynke S; van Leeuwen, Fijs W B; Haller, Bernhard; Horn, Thomas; Heck, Matthias M; Gschwend, Jürgen E; Schwaiger, Markus; Wester, Hans-Jürgen; Eiber, Matthias

    2018-04-03

    Prostate-specific membrane antigen (PSMA)-targeted positron emission tomography (PET) can visualize metastatic lesions in recurrent prostate cancer (PC). However, reliable identification of small and/or atypically localized lesions during salvage surgery procedures is challenging. To describe the technique, feasibility, and short-term outcomes of 99m Technetium ( 99m Tc)-based PSMA-radioguided surgery ( 99m Tc-PSMA-RGS) for removal of recurrent PC lesions. Thirty-one consecutive patients with evidence of recurrent PC on 68 Ga-PSMA N,N'-bis[2-hydroxy-5-(carboxyethyl)benzyl] ethylenediamine-N,N'-diacetic acid ( 68 Ga-PSMA-11) PET after radical prostatectomy undergoing 99m Tc-PSMA-RGS were retrospectively analyzed. Salvage surgery with intraoperative radioguidance using a gamma probe was performed after intravenous application of 99m Tc-PSMA investigation and surgery (mean activity 571 MBq, mean time to surgery 19.7h). Radioactive rating (positive vs negative) of resected tissue was compared with the findings of postoperative histopathological analysis. Best prostate-specific antigen (PSA) response without additional treatment was determined after 8-16 wk postoperatively. Biochemical recurrence- and treatment-free survival was evaluated. In total, 132 tissue specimens were removed, of which 58 showed metastatic involvement on histological analysis. On a specimen basis, radioactive rating yielded a sensitivity of 83.6% (confidence interval [CI]: 70.9-91.5%), a specificity of 100%, and an accuracy of 93.0% (CI: 85.5-96.7%). With 99m Tc-PSMA-RGS, all lesions visualized on preoperative 68 Ga-PSMA-11 PET could be removed. Moreover, 99m Tc-PSMA-RGS detected additional metastases as small as 3mm in two patients. Thirteen patients suffered from complications related to surgery (Clavien-Dindo grade 1: 12 patients; grade 3a: one patient). A PSA reduction below 0.2 ng/ml was observed in 20 patients. Thirteen patients remained biochemical recurrence free after a median follow

  15. Diffusion of 99-technetium in compacted bentonite under aerobic and anaerobic conditions

    NASA Astrophysics Data System (ADS)

    Večerník, P.; Jedináková-Křížová, V.

    2006-01-01

    The main aim of this study was to investigate diffusion of technetium 99Tc under different conditions. Because technetium represents one of the most dangerous fission products due to its very long halftime and high mobility in aerobic conditions diffusion experiments of technetium (as 99TcO 4 - anion) in Czech bentonite from Rokle locality have been carried out. For performance and evaluation of experiments the through-diffusion method was chosen and apparent (Da) and effective (De) diffusion coefficients were evaluated. The effects of particle mesh-size, dry bulk density and aerobic or anaerobic conditions on diffusion were studied. In the presence of oxygen, technetium occurs in oxidation state VII, as an anion, soluble and mobile in the environment. However, under reducing conditions it occurs in a lower oxidation states, mainly as insoluble oxides or hydroxides. Aerobic experiments were carried out under laboratory conditions and anaerobic experiments were performed in a nitrogen atmosphere in a glove box, to simulate the real underground conditions.

  16. Effect of metabolic alterations on the accumulation of technetium-99m-labeled d, l-HMPAO in slices of rat cerebral cortex

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahn, C.S.; Tow, D.E.; Yu, C.C.

    1994-03-01

    It is widely recognized that the distribution of technetium-99m-labeled d,l-hexamethylpropylene amine oxime ({sup 99m}Tc-HMPAO) in the brain is determined by the regional blood flow. However, other factors may affect this process including the metabolism of the brain tissue. To examine this possibility we studied the effects of metabolic alterations on {sup 99m}Tc-HMPAO uptake in rat brain cortex slices, with concurrent measurement of oxygen consumption (QO{sub 2}). {sup 99m}Tc-HMPAO uptake was determined by incubating slices of rat cerebral cortex at 37{degrees}C in Krebs-Ringer phosphate glucose medium containing {sup 99m}Tc-HMPAO with and without test substances. Differential gradients for {sup 99m}Tc activity betweenmore » the tissue and the suspending medium (T/M ratio) were derived from the equation T/M[{sup 99m}Tc] = counts per gram of tissue/counts per milliliter of medium. The QO{sub 2} of the brain slices was measured using a biological oxygen monitor equipped with a polarographic oxygen probe. Inhibitors affecting oxidative phosphorylation caused parallel suppression of the T/M ratio and QO{sub 2}. Agents that uncouple oxidation from phosphorylation increased the QO{sub 2} and decreased the T/M ratio. Incubation of slices at 22{degrees}C depressed the T/M ratio and QO{sub 2}. The presence of inhibitors of oxidative phosphorylation in the incubation medium increased the release of {sup 99m}Tc activity from slices that had been prelabeled with {sup 99m}Tc-HMPAO. These findings suggest that the altered metabolic status of the brain tissue modulates the kinetics and net accumulation of {sup 99m}Tc-HMPAO at the cellular level by either depressing uptake, increasing back-diffusion, or both. 33 refs., 4 figs., 3 tabs.« less

  17. Regional cerebral blood flow (rCBF) in schizophrenia during verbal memory activation: a 99mTc-HMPAO single photon emission tomography (SPET) study.

    PubMed

    Busatto, G F; Costa, D C; Ell, P J; Pilowsky, L S; David, A S; Kerwin, R W

    1994-05-01

    Regional cerebral blood flow (rCBF) was investigated in a group of medicated DSM-III-R schizophrenic patients and age, sex and handedness matched normal volunteers using a split-dose 99mTc-HMPAO Single Photon Emission Tomography (SPET) protocol. Measures were taken during the performance of a verbal memory task aimed at activating the left medial temporal lobe, a region repeatedly suggested to be structurally abnormal in schizophrenia. In normal subjects, the performance of the task was associated with significant rCBF increases in the left medial temporal, left inferior frontal and anterior cingulate cortices, and right cerebellum. Despite their significantly poorer performance on the memory task, the degree of medial temporal activation measured in the schizophrenic patients was not significantly different from that found in the control group. This finding suggests that memory deficits in schizophrenia do not necessarily imply failure to activate the left medial temporal lobe as assessed by 99mTc-HMPAO SPET.

  18. Usefulness of Tc99m-mebrofenin Hepatobiliary Scintigraphy and Single Photon Emission Computed Tomography/Computed Tomography in the Diagnosis of Bronchobiliary Fistula.

    PubMed

    Parghane, Rahul Vithalrao; Phulsunga, Rohit Kumar; Gupta, Rajesh; Basher, Rajender Kumar; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2017-01-01

    Bronchobiliary fistula (BBF), a rare complication of liver disease, is an abnormal communication between the biliary tract and bronchial tree. BBF may occur as a consequence of local liver infections such as hydatid or amebic disease, pyogenic liver abscess or trauma to the liver, obstruction of biliary tract, and tumor. As such management of liver disease with BBF is very difficult and often associated with a high rate of morbidity and mortality. Therefore, timely diagnosis of BBF is imperative. Hepatobiliary scintigraphy along with hybrid single photon emission computed tomography/computed tomography using Tc99m-mebrofenin is a very useful noninvasive imaging modality, in the diagnosis of BBF.

  19. Usefulness of Tc99m-mebrofenin Hepatobiliary Scintigraphy and Single Photon Emission Computed Tomography/Computed Tomography in the Diagnosis of Bronchobiliary Fistula

    PubMed Central

    Parghane, Rahul Vithalrao; Phulsunga, Rohit Kumar; Gupta, Rajesh; Basher, Rajender Kumar; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2017-01-01

    Bronchobiliary fistula (BBF), a rare complication of liver disease, is an abnormal communication between the biliary tract and bronchial tree. BBF may occur as a consequence of local liver infections such as hydatid or amebic disease, pyogenic liver abscess or trauma to the liver, obstruction of biliary tract, and tumor. As such management of liver disease with BBF is very difficult and often associated with a high rate of morbidity and mortality. Therefore, timely diagnosis of BBF is imperative. Hepatobiliary scintigraphy along with hybrid single photon emission computed tomography/computed tomography using Tc99m-mebrofenin is a very useful noninvasive imaging modality, in the diagnosis of BBF. PMID:29033682

  20. Early identification of amyloid heart disease by technetium-99m-pyrophosphate scintigraphy: a study with familial amyloid polyneuropathy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hongo, M.; Hirayama, J.; Fujii, T.

    1987-03-01

    To determine whether technetium-99m-pyrophosphate (Tc-99m-PYP) scanning or two-dimensional echocardiography can detect amyloid heart disease in an earlier stage of familial amyloid polyneuropathy, 15 patients were examined. Although 10 of the 15 patients had no clinical evidence of congestive heart failure, as well as normal ventricular wall thickness and normal values for left ventricular systolic function, five (50%) of them showed mild or moderate myocardial uptake. On the other hand, none had characteristic highly refractile myocardial echoes on the two-dimensional echocardiographic images (p less than 0.01), and values for diastolic function were reduced in four of the five and normal inmore » the remaining one. In 85 control subjects, diffuse positive pyrophosphate scans of the heart were found in four (5%) of them (three with dilated cardiomyopathy and one with sarcoidosis), and highly refractile granular sparkling echoes were observed in nine (11%) (five with hypertrophic cardiomyopathy, three with aortic stenosis, and one with hypereosinophilic syndrome). We conclude that Tc-99m-PYP scanning is a more sensitive and specific method and may have the potential ability to detect amyloid heart disease in the earlier stage of familial amyloid polyneuropathy than two-dimensional echocardiography.« less

  1. Technetium-99m-labeled rituximab for use as a specific tracer of sentinel lymph node biopsy: a translational research study.

    PubMed

    Wang, Xuejuan; Yang, Zhi; Lin, Baohe; Zhang, Yan; Zhai, Shizhen; Zhao, Qichao; Xie, Qing; Liu, Fei; Han, Xuedi; Li, Jinfeng; Ouyang, Tao

    2016-06-21

    We aimed to develop and translate a CD20-antigen-targeted radiopharmaceutical, Technetium-99 m-labeled (99mTc) rituximab, for sentinel lymph node (SLN) detection. 99mTc-rituximab was synthesized and tested for stability in human serum. The binding affinity to CD20 was evaluated in Raji cells by flow cytometric analysis. Biodistribution and sentinel node mapping were carried out in bal b/c mice. Eighty-five patients with breast cancer participated in this study. Dynamic sentinel lymphoscintigraphy was first assessed in 12 patients before planar lymphoscintigraphy was assessed in a larger cohort. All patients underwent sentinel lymph node biopsy (SLNB), followed by axillary lymph node dissection. The cell-binding study showed that 99mTc-rituximab possessed compatible affinity to human CD20. In the mechanism study, 99mTc-labeled anti-mouse CD20 monoclonal antibodies could bind to mouse CD20 and accumulate in the SLN with 2.62±1.25 % of the percentage of injected activity, which could be blocked by excessive unlabeled antibody. Low uptake of non-sentinel nodes and fast clearance from the injection site were observed in the mice. Sentinel nodes were identified in 82 of 85 breast cancer patients (96.5%) by lymphoscintigraphy and SLNB. The sensitivity, specificity, and accuracy were 96.8% (30/31), 100% (51/51), and 98.8% (81/82), respectively. 99mTc-rituximab, specifically binding to CD20, met most of the requirements of an ideal sentinel mapping agent for use in clinical settings.

  2. Correlation of Tc-99 m ethyl cysteinate dimer single-photon emission computed tomography and clinical presentations in patients with low cobalamin status.

    PubMed

    Tu, Min-Chien; Lo, Chung-Ping; Chen, Ching-Yuan; Huang, Ching-Feng

    2015-12-03

    Cobalamin (Cbl) deficiency has been associated with various neuropsychiatric symptoms of different severities. While some studies dedicated in structural neuroimaging credibly address negative impact of low Cbl status, functional imaging reports are limited. We herein retrospectively review the correlation of Tc-99 m ethyl cysteinate dimer single-photon emission computed tomography (Tc-99 m-ECD SPECT) and clinical presentations among patients with low serum cobalamin (Cbl) status (<250 pg/ml). Twelve symptomatic patients with low serum Cbl status were enrolled. Clinical presentations, Tc-99 m-ECD SPECT, and neuropsychological tests were reviewed. Dysexecutive syndrome (67 %), forgetfulness (50 %), attention deficits (42 %), and sleep disorders (33 %) constituted the major clinical presentations. All patients (100 %) had temporal hypoperfusion on the Tc-99 m-ECD SPECT. Five patients (42 %) had hypoperfusion restricted within temporal regions and deep nuclei; seven patients (58 %) had additional frontal hypoperfusion. In patients with hypoperfusion restricted within temporal regions and deep nuclei, psychiatric symptoms with spared cognition were their main presentations. Among patients with additional frontal hypoperfusion, six of seven patients (86 %) showed impaired cognitive performances (two of them were diagnosed as having dementia). Among ten patients who finished neuropsychological tests, abstract thinking (70 %) was the most commonly affected, followed by verbal fluency (60 %), short-term memory (50 %), and attention (50 %). Anxiety and sleep problems were the major clinically remarkable psychiatric features (33 % both). Four Tc-99 m-ECD SPECT follow-up studies were available; the degree and extent of signal reversal correlated with cognitive changes after Cbl replacement therapy. Our TC-99 m-ECD SPECT observations provide pivotal information of neurobiological changes within basal ganglia and fronto-temporal regions in conjunction with disease severity

  3. In-house cyclotron production of high-purity Tc-99m and Tc-99m radiopharmaceuticals.

    PubMed

    Martini, Petra; Boschi, Alessandra; Cicoria, Gianfranco; Zagni, Federico; Corazza, Andrea; Uccelli, Licia; Pasquali, Micòl; Pupillo, Gaia; Marengo, Mario; Loriggiola, Massimo; Skliarova, Hanna; Mou, Liliana; Cisternino, Sara; Carturan, Sara; Melendez-Alafort, Laura; Uzunov, Nikolay M; Bello, Michele; Alvarez, Carlos Rossi; Esposito, Juan; Duatti, Adriano

    2018-05-30

    In the last years, the technology for producing the important medical radionuclide technetium-99m by cyclotrons has become sufficiently mature to justify its introduction as an alternative source of the starting precursor [ 99m Tc][TcO 4 ] - ubiquitously employed for the production of 99m Tc-radiopharmaceuticals in hospitals. These technologies make use almost exclusively of the nuclear reaction 100 Mo(p,2n) 99m Tc that allows direct production of Tc-99m. In this study, it is conjectured that this alternative production route will not replace the current supply chain based on the distribution of 99 Mo/ 99m Tc generators, but could become a convenient emergency source of Tc-99m only for in-house hospitals equipped with a conventional, low-energy, medical cyclotron. On this ground, an outline of the essential steps that should be implemented for setting up a hospital radiopharmacy aimed at the occasional production of Tc-99m by a small cyclotron is discussed. These include (1) target production, (2) irradiation conditions, (3) separation/purification procedures, (4) terminal sterilization, (5) quality control, and (6) Mo-100 recovery. To address these issues, a comprehensive technology for cyclotron-production of Tc-99m, developed at the Legnaro National Laboratories of the Italian National Institute of Nuclear Physics (LNL-INFN), will be used as a reference example. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. Investigating the Role of Global Histogram Equalization Technique for 99mTechnetium-Methylene diphosphonate Bone Scan Image Enhancement.

    PubMed

    Pandey, Anil Kumar; Sharma, Param Dev; Dheer, Pankaj; Parida, Girish Kumar; Goyal, Harish; Patel, Chetan; Bal, Chandrashekhar; Kumar, Rakesh

    2017-01-01

    99m Technetium-methylene diphosphonate ( 99m Tc-MDP) bone scan images have limited number of counts per pixel, and hence, they have inferior image quality compared to X-rays. Theoretically, global histogram equalization (GHE) technique can improve the contrast of a given image though practical benefits of doing so have only limited acceptance. In this study, we have investigated the effect of GHE technique for 99m Tc-MDP-bone scan images. A set of 89 low contrast 99m Tc-MDP whole-body bone scan images were included in this study. These images were acquired with parallel hole collimation on Symbia E gamma camera. The images were then processed with histogram equalization technique. The image quality of input and processed images were reviewed by two nuclear medicine physicians on a 5-point scale where score of 1 is for very poor and 5 is for the best image quality. A statistical test was applied to find the significance of difference between the mean scores assigned to input and processed images. This technique improves the contrast of the images; however, oversaturation was noticed in the processed images. Student's t -test was applied, and a statistically significant difference in the input and processed image quality was found at P < 0.001 (with α = 0.05). However, further improvement in image quality is needed as per requirements of nuclear medicine physicians. GHE techniques can be used on low contrast bone scan images. In some of the cases, a histogram equalization technique in combination with some other postprocessing technique is useful.

  5. Influence of exercise on the distribution of technetium Tc 99m medronate following intra-articular injection in horses.

    PubMed

    Dulin, Jennifer A; Drost, W Tod; Phelps, Mitch A; Santschi, Elizabeth M; Menendez, Maria I; Bertone, Alicia L

    2012-03-01

    To determine the effects of exercise on the distribution and pharmacokinetics of technetium Tc 99m medronate ((99m)Tc-MDP) following intra-articular (IA) injection in horses. 5 horses. 1 antebrachiocarpal joint (ACJ)/horse was assigned to the exercised group (n = 5), and the contralateral ACJ was evaluated in the nonexercised group (5) after a minimum washout period of 7 days. Following IA injection of (99m)Tc-MDP (148 MBq), blood and scintigraphic images of the carpus were obtained at 5, 10, 15, 20, 25, 30, 45, 60, 90, 120, 240, 360, 480, 600, 720, and 1,440 minutes. Plasma and scintigraphic radioactivity were determined over time, and pharmacokinetic parameters were generated via noncompartmental and compartmental analyses. Each horse was monitored via physical and lameness examination and ACJ synovial fluid analysis before injection and at days 1, 2, 3, and 7. Lameness was not observed. Mean ± SD synovial fluid WBC count increased at day 1 (exercised, 721 ± 234 cells/μL; nonexercised, 948 ± 223 cells/μL), but returned to baseline at days 3 and 7 Mean time to maximum plasma radioactivity was earlier in the exercised group (16.00 ± 2.35 minutes) than the nonexercised group (43.75 ± 3.64 minutes). Linear regression of the scintigraphic radioactivity-time curves revealed a greater negative slope in the exercised group within the first 25 minutes. There was no difference in absorption or elimination rate constants in a 2-compartment model. IA injection of (99m)Tc-MDP was safe and effective for evaluating synovial solute distribution. Exercise significantly increased early transfer of (99m)Tc-MDP from the ACJ into plasma, although absorption and elimination rate constants were not affected. Exercise may affect synovial clearance and withdrawal times of medications administered IA.

  6. Effects of positive expiratory pressure on pulmonary clearance of aerosolized technetium-99m-labeled diethylenetriaminepentaacetic acid in healthy individuals

    PubMed Central

    de Albuquerque, Isabella Martins; Cardoso, Dannuey Machado; Masiero, Paulo Ricardo; Paiva, Dulciane Nunes; Resqueti, Vanessa Regiane; Fregonezi, Guilherme Augusto de Freitas; Menna-Barreto, Sérgio Saldanha

    2016-01-01

    ABSTRACT Objective: To evaluate the effects of positive expiratory pressure (PEP) on pulmonary epithelial membrane permeability in healthy subjects. Methods: We evaluated a cohort of 30 healthy subjects (15 males and 15 females) with a mean age of 28.3 ± 5.4 years, a mean FEV1/FVC ratio of 0.89 ± 0.14, and a mean FEV1 of 98.5 ± 13.1% of predicted. Subjects underwent technetium-99m-labeled diethylenetriaminepentaacetic acid (99mTc-DTPA) radioaerosol inhalation lung scintigraphy in two stages: during spontaneous breathing; and while breathing through a PEP mask at one of three PEP levels-10 cmH2O (n = 10), 15 cmH2O (n = 10), and 20 cmH2O (n = 10). The 99mTc-DTPA was nebulized for 3 min, and its clearance was recorded by scintigraphy over a 30-min period during spontaneous breathing and over a 30-min period during breathing through a PEP mask. Results: The pulmonary clearance of 99mTc-DTPA was significantly shorter when PEP was applied-at 10 cmH2O (p = 0.044), 15 cmH2O (p = 0.044), and 20 cmH2O (p = 0.004)-in comparison with that observed during spontaneous breathing. Conclusions: Our findings indicate that PEP, at the levels tested, is able to induce an increase in pulmonary epithelial membrane permeability and lung volume in healthy subjects. PMID:28117469

  7. Assessment of the direct cyclotron production of (99m)Tc: An approach to crisis management of (99m)Tc shortage.

    PubMed

    Rovais, Mohammad Reza Aboudzadeh; Aardaneh, Khosro; Aslani, Gholamreza; Rahiminejad, Ali; Yousefi, Kamran; Boulouri, Fatemeh

    2016-06-01

    Nowadays, the cyclotron production of technetium-99m ((99m)Tc) has been increased, due to the worldwide (99m)Tc generator shortage. In the present work, an improved strategy for the production of (99m)Tc, using the proton irradiation of the enriched (100)Mo was developed. The performance of this method in terms of the production yield, chemical purity, radiochemical purity, as well as radionuclide purity was evaluated. The average production yield was measured to be 356MBqμA(-1)h(-1). A good agreement was found between the calculated production yield and the experimental one. The radiochemical separation and total recovery yields of (99m)Tc were 92% and 69%, respectively. The radiochemical and the radionuclide purities of the (99m)Tc were 99% and >99.99% at the end of purification, respectively. The results of quality control tests (QC) support the concept that cyclotron-produced (99m)Tc is suitable for preparation of USP-compliant. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Immobilization and Limited Reoxidation of Technetium-99 by Fe(II)-Goethite

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Um, Wooyong; Chang, Hyun-shik; Icenhower, Jonathan P.

    2010-09-30

    This report summarizes the methodology used to test the sequestration of technetium-99 present in both deionized water and simulated Hanford Tank Waste Treatment and Immobilization Plant waste solutions.

  9. Techniques for Loading Technetium-99m and Rhenium-186/188 Radionuclides into Preformed Liposomes for Diagnostic Imaging and Radionuclide Therapy.

    PubMed

    Goins, Beth; Bao, Ande; Phillips, William T

    2017-01-01

    Liposomes can serve as carriers of radionuclides for diagnostic imaging and therapeutic applications. Herein, procedures are outlined for radiolabeling liposomes with the gamma-emitting radionuclide, technetium-99m ( 99m Tc), for noninvasive detection of disease and for monitoring the pharmacokinetics and biodistribution of liposomal drugs, and/or with therapeutic beta-emitting radionuclides, rhenium-186/188 ( 186/188 Re), for radionuclide therapy. These efficient and practical liposome radiolabeling methods use a post-labeling mechanism to load 99m Tc or 186/188 Re into preformed liposomes prepared in advance of the labeling procedure. For all liposome radiolabeling methods described, a lipophilic chelator is used to transport 99m Tc or 186/188 Re across the lipid bilayer of the preformed liposomes. Once within the liposome interior, the pre-encapsulated glutathione or ammonium sulfate (pH) gradient provides for stable entrapment of the 99m Tc and 186/188 Re within the liposomes. In the first method, 99m Tc is transported across the lipid bilayer by the lipophilic chelator, hexamethylpropyleneamine oxime (HMPAO) and 99m Tc-HMPAO becomes trapped by interaction with the pre-encapsulated glutathione within the liposomes. In the second method, 99m Tc or 186/188 Re is transported across the lipid bilayer by the lipophilic chelator, N,N-bis(2-mercaptoethyl)-N',N'-diethylethylenediamine (BMEDA), and 99m Tc-BMEDA or 186/188 Re-BMEDA becomes trapped by interaction with pre-encapsulated glutathione within the liposomes. In the third method, an ammonium sulfate (pH) gradient loading technique is employed using liposomes with an extraliposomal pH of 7.4 and an interior pH of 5.1. BMEDA, which is lipophilic at pH 7.4, serves as a lipophilic chelator for 99m Tc or 186/188 Re to transport the radionuclides across the lipid bilayer. Once within the more acidic liposome interior, 99m Tc/ 186/188 Re-BMEDA complex becomes protonated and more hydrophilic, which results in stable

  10. Investigating the Role of Global Histogram Equalization Technique for 99mTechnetium-Methylene diphosphonate Bone Scan Image Enhancement

    PubMed Central

    Pandey, Anil Kumar; Sharma, Param Dev; Dheer, Pankaj; Parida, Girish Kumar; Goyal, Harish; Patel, Chetan; Bal, Chandrashekhar; Kumar, Rakesh

    2017-01-01

    Purpose of the Study: 99mTechnetium-methylene diphosphonate (99mTc-MDP) bone scan images have limited number of counts per pixel, and hence, they have inferior image quality compared to X-rays. Theoretically, global histogram equalization (GHE) technique can improve the contrast of a given image though practical benefits of doing so have only limited acceptance. In this study, we have investigated the effect of GHE technique for 99mTc-MDP-bone scan images. Materials and Methods: A set of 89 low contrast 99mTc-MDP whole-body bone scan images were included in this study. These images were acquired with parallel hole collimation on Symbia E gamma camera. The images were then processed with histogram equalization technique. The image quality of input and processed images were reviewed by two nuclear medicine physicians on a 5-point scale where score of 1 is for very poor and 5 is for the best image quality. A statistical test was applied to find the significance of difference between the mean scores assigned to input and processed images. Results: This technique improves the contrast of the images; however, oversaturation was noticed in the processed images. Student's t-test was applied, and a statistically significant difference in the input and processed image quality was found at P < 0.001 (with α = 0.05). However, further improvement in image quality is needed as per requirements of nuclear medicine physicians. Conclusion: GHE techniques can be used on low contrast bone scan images. In some of the cases, a histogram equalization technique in combination with some other postprocessing technique is useful. PMID:29142344

  11. Prospective Evaluation of (99m)Tc-sestamibi SPECT/CT for the Diagnosis of Renal Oncocytomas and Hybrid Oncocytic/Chromophobe Tumors.

    PubMed

    Gorin, Michael A; Rowe, Steven P; Baras, Alexander S; Solnes, Lilja B; Ball, Mark W; Pierorazio, Phillip M; Pavlovich, Christian P; Epstein, Jonathan I; Javadi, Mehrbod S; Allaf, Mohamad E

    2016-03-01

    Nuclear imaging offers a potential noninvasive means of determining the histology of renal tumors. The aim of this study was to evaluate the accuracy of technetium-99m ((99m)Tc)-sestamibi single-photon emission computed tomography/x-ray computed tomography (SPECT/CT) for the differentiation of oncocytomas and hybrid oncocytic/chromophobe tumors (HOCTs) from other renal tumor histologies. In total, 50 patients with a solid clinical T1 renal mass were imaged with (99m)Tc-sestamibi SPECT/CT prior to surgical resection. Preoperative SPECT/CT scans were reviewed by two blinded readers, and their results were compared with centrally reviewed surgical pathology data. Following surgery, 6 (12%) tumors were classified as renal oncocytomas and 2 (4%) as HOCTs. With the exception of 1 (2%) angiomyolipoma, all other tumors were renal cell carcinomas (82%). (99m)Tc-sestamibi SPECT/CT correctly identified 5 of 6 (83.3%) oncocytomas and 2 of 2 (100%) HOCTs, resulting in an overall sensitivity of 87.5% (95% confidence interval [CI], 47.4-99.7%). Only two tumors were falsely positive on SPECT/CT, resulting in a specificity of 95.2% (95% CI, 83.8-99.4%). In summary, (99m)Tc-sestamibi SPECT/CT is a promising imaging test for the noninvasive diagnosis of renal oncocytomas and HOCTs. We found that the imaging test (99m)Tc-sestamibi SPECT/CT can be used to accurately diagnose two types of benign kidney tumors. This test may be eventually used to help better evaluate patients diagnosed with a renal tumor. Copyright © 2015 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  12. Techniques for loading technetium-99m and rhenium-186/188 radionuclides into pre-formed liposomes for diagnostic imaging and radionuclide therapy.

    PubMed

    Goins, Beth; Bao, Ande; Phillips, William T

    2010-01-01

    Liposomes can serve as carriers of radionuclides for diagnostic imaging and therapeutic applications. Herein, procedures are outlined for radiolabeling liposomes with the gamma-emitting radionuclide, technetium-99m ((99m)Tc), for non-invasive detection of disease and for monitoring the pharmacokinetics and biodistribution of liposomal drugs, and/or with therapeutic beta-emitting radionuclides, rhenium-186/188 ((186/188)Re), for radionuclide therapy. These efficient and practical liposome radiolabeling methods use a post-labeling mechanism to load (99m)Tc or (186/188)Re into pre-formed liposomes prepared in advance of the labeling procedure. For all liposome radiolabeling methods described, a lipophilic chelator is used to transport (99m)Tc or (186/188)Re across the lipid bilayer of the pre-formed liposomes. Once within the liposome interior, the pre-encapsulated glutathione or ammonium sulfate (pH) gradient provides for stable entrapment of the (99m)Tc and (186/188)Re within the liposomes. In the first method, (99m)Tc is transported across the lipid bilayer by the lipophilic chelator, hexamethylpropyleneamine oxime (HMPAO) and (99m)Tc-HMPAO becomes trapped by interaction with the pre-encapsulated glutathione within the liposomes. In the second method, (99m)Tc or (186/188)Re is transported across the lipid bilayer by the lipophilic chelator, N,N-bis(2-mercaptoethyl)-N',N'-diethylethylenediamine (BMEDA), and (99m)Tc-BMEDA or (186/188)Re-BMEDA becomes trapped by interaction with pre-encapsulated glutathione within the liposomes. In the third method, an ammonium sulfate (pH) gradient loading technique is employed using liposomes with an extraliposomal pH of 7.4 and an interior pH of 5.1. BMEDA, which is lipophilic at pH 7.4, serves as a lipophilic chelator for (99m)Tc or (186/188)Re to transport the radionuclides across the lipid bilayer. Once within the more acidic liposome interior, (99m)Tc/(186/188)Re-BMEDA complex becomes protonated and more hydrophilic, which

  13. An incidentally found inflamed uterine myoma causing low abdominal pain, using Tc-99m-tektrotyd single photon emission computed tomography-CT hybrid imaging.

    PubMed

    Zandieh, Shahin; Schütz, Matthias; Bernt, Reinhard; Zwerina, Jochen; Haller, Joerg

    2013-01-01

    We report the case of a 50-year-old woman presented with a history of right hemicolectomy due to an ileocecal neuroendocrine tumor and left breast metastasis. Owing to a slightly elevated chromogranin A-level and lower abdominal pain, single photon emission computed tomography-computer tomography (SPECT-CT) was performed. There were no signs of recurrence on the SPECT-CT scan, but the patient was incidentally found to have an inflamed intramural myoma. We believe that the slightly elevated chromogranin A-level was caused by the hypertension that the patient presented. In the clinical context, this is a report of an inflamed uterine myoma seen as a false positive result detected by TC-99m-Tc-EDDA/HYNIC-Tyr3-Octreotide (Tektrotyd) SPECT-CT hybrid imaging.

  14. Calculation of therapeutic activity of radioiodine in Graves' disease by means of Marinelli's formula, using technetium (99mTc) scintigraphy.

    PubMed

    Szumowski, Piotr; Mojsak, Małgorzata; Abdelrazek, Saeid; Sykała, Monika; Amelian-Fiłonowicz, Anna; Jurgilewicz, Dorota; Myśliwiec, Janusz

    2016-12-01

    The therapeutic activity of 131 I administered to patients with Graves' disease can be calculated by means of Marinelli's formula. The thyroidal iodine uptake ( 131 IU max ) needed for the calculation is usually determined with the use of 131 I. The purpose of the paper was to estimate 131 IU max on the basis of technetium uptake in the thyroid at 20 min ( 99m TcU 20min ). Eighty patients suffering from Graves' disease were qualified for radioiodine therapy with measurement of fT 4 , fT 3 , thyroid-stimulating hormone and its receptor (TRAb). Prior to the treatment, all the patients were euthyroid. 131 IU max for each patient was determined according to the levels of 131 I after 24 h ( 131 IU 24h ), while effective half-life (T eff ) according to the measurements of 131 IU 24h and 131 I uptake after 48 h ( 131 IU 48h ). Additionally, on the day before measuring 131 IU 24h , 99m TcU 20min was calculated for each patient. It was demonstrated that there existed a correlation, with statistical significance at p < 0.05, between the following pairs of values: TRAb and 131 IU 24h , TRAb and 99m TcU 20min , and 99m TcU 20min and 131 IU 24h . The interdependence between 131 IU 24h and 99m TcU 20min at the level of significance p < 0.05 is described by the following algorithms: 131 IU 24h  = 17.72 × ln ( 99m TcU 20min ) + 30.485, if TRAb < 10 IU/ml, and 131 IU 24h  = 18.03 × ln ( 99m TcU 20min ) + 38.726, if TRAb > 10 IU/ml. It is possible to predict thyroid iodine uptake 131 IU 24h in Graves' disease on the basis of measuring the uptake of 99m TcU 20min . This shortens the time necessary for diagnosis and enables the calculation of 131 I activity using Marinelli's formula.

  15. Technetium-99m sestamibi scintimammography complements mammography in the detection of breast cancer.

    PubMed

    Krishnaiah, Gayathri; Sher-Ahmed, Arifa; Ugwu-Dike, Martins; Regan, Patricia; Singer, John; Totoonchie, Adil; Spiegler, Ethan; Sardi, Armando

    2003-01-01

    Mammography remains the technique of choice for the detection of early breast cancer. The sensitivity of mammography is 85%, but is decreased in patients with dense breasts. Sestamibi scintimammography (SCM) has been suggested as an adjunctive modality to improve the detection of breast cancer. We conducted a study to determine the impact of SCM in patient management. A prospective study was conducted in 95 patients presenting with palpable masses and/or abnormal mammography scheduled for biopsy. Injection of 20-30 mCi of technetium-99m (Tc-99m) sestamibi into a pedal vein was performed. Ten-minute images of the breast and axilla were obtained in multiple projections. The mammography and SCM were correlated with pathology and clinical findings. The median age was 44 years (range 28-86 years). The total number of lesions was 104, as eight patients had bilateral lesions and one patient had two lesions in the same breast. Fifty-nine patients presented with palpable lesions and 45 patients with nonpalpable lesions (42 with abnormal mammography only and 3 with nipple discharge). A comparison of sensitivity, specificity, positive and negative predictive values, and overall accuracy of SCM and mammography were performed. The sensitivity and specificity for SCM were 83% and 83%, respectively, and for mammography were 65%, and 72%, respectively. The sensitivity and specificity for combined SCM and mammography were 87% and 94%, respectively. The p-value for mammography versus combined SCM and mammography was 0.0003 and that for SCM versus SCM and mammography was 0.0098. There were 80 (77%) benign and 24 (23%) malignant lesions. Of the 24 malignancies, SCM missed six (25%), versus eight (33%) by mammography. In two patients (9%) SCM detected malignancy in the breast that was not visualized by mammography or found on clinical examination. Sestamibi SCM improves the sensitivity of mammography and it detects up to 9% of malignancies not detected by mammography or clinical

  16. Sectorial technetium-99m-dimercaptosuccinic acid scintigraphy for monitoring the effect of extracorporeal piezoelectric lithotripsy for calyceal calculi on regional renal function.

    PubMed

    Al-Tawheed, A; Al-Awadi, K A; Kehinde, E O; Loutfi, I; Abdul-Haleem, H; Al-Mohannadi, S

    2003-01-01

    To apply a semiquantitative method for analysis of technetium-99m-dimercaptosuccinic acid ((99m)Tc-DMSA) renal scintigraphy for monitoring the effect of extracorporeal piezoelectric lithotripsy (EPL) in patients with calyceal stones on regional kidney function and to check whether EPL had caused any deleterious effect on the target calyceal renal parenchymal function. Forty patients (mean age 35 years) suffering from calyceal stones documented by abdominal plain radiography, intravenous urogram or abdominal ultrasound were studied. All patients were treated by EPL. (99m)Tc-DMSA scan was performed before and 4 weeks after EPL. Sector analysis involved calculation of the relative function of the target calyx to the function of the ipsilateral kidney and the relative function of the treated kidney to global renal function. The stone sizes were 6-11 mm in diameter and 11 were located in the upper, 13 in the middle and 16 in the lower calyx. After EPL, the overall stone clearance rate was 85% (100% for calculi in the upper and middle calyces, 62% for lower calyces). The sector analysis did not show statistically significant change of the relative regional (calyceal) or whole kidney function between the pre- and post-EPL (99m)Tc-DMSA scans. Using sector analysis, EPL appeared to be a safe modality and its usage was not associated with any untoward effect on calyceal or whole kidney function. Sector analysis of (99m)Tc-DMSA renal scan is a simple semiquantitative method for monitoring regional changes of kidney function after EPL for treatment of calyceal stone. Copyright 2003 S. Karger AG, Basel

  17. Axillary lymph node uptake of technetium-99m-MDP

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ongseng, F.; Goldfarb, C.R.; Finestone, H.

    We sought to determine the frequency and significance of axillary lymph node visualization on bone scans performed with diphosphonates. Consecutive {sup 99m}Tc-methylene diphosphonate ({sup 99m}Tc-MDP) bone scans (2435) were inspected for axillary soft-tissue uptake. In positive cases, the results of physical examination, correlative imaging studies and serial bone scans were recorded, as was the site of venipuncture. Forty-eight studies (2%) showed axillary uptake ipsilateral to the injection site. Extravasation of tracer, documented by focal activity near the injection site, was present in every case. There was no association with axillary adenopathy, mass, induration of radiographically visible calcification. On some images,more » foci adjacent to the axilla were superimposed on the rib, scapula, or humerus. The bone-to-background ratio was frequently reduced; repeat imaging after 1-2 hr usually improved osseous detail. Ipsilateral axillary lymph node visualization due to extravasation of {sup 99m}Tc-MDP is frequently associated with additional foci superimposed on osseous structures simulating pathology. Delayed skeletal uptake is common in such cases and necessitates a greater time interval between injection and imaging. 7 refs., 3 figs.« less

  18. Improvement of Cerebral Hypoperfusion with Levothyroxine Therapy in Hashimoto's Encephalopathy Demonstrated by 99mTc-HMPAO-SPECT

    PubMed Central

    Schnedl, Wolfgang J.; Mirzaei, Siroos; Wallner-Liebmann, Sandra J.; Tafeit, Erwin; Mangge, Harald; Krause, Robert; Lipp, Rainer W.

    2013-01-01

    Background Hashimoto's encephalopathy (HE) is a rare immune-mediated encephalopathy associated with autoimmune Hashimoto's thyroiditis. Objectives and Methods We report on a patient with HE and significant clinical improvement correlating with an increase in cerebral blood flow demonstrated by hexamethylpropyleneamine oxime (HMPAO) single-photon emission computed tomography (SPECT). HMPAO-SPECT was performed with 740 MBq of technetium-99m-HMPAO. To demonstrate the improvement in regional cerebral blood flow, individual regions of interest were drawn around visually diminished HMPAO uptake, the lesion to reference region ratio was calculated and transverse section images and semi-quantitative measurements were performed. Results We show a 5-year follow-up with significant clinical improvement, a 10-fold reduction in autoantibodies to thyroid peroxidase and an approximately 20% improvement in cerebral blood flow with HMPAO-SPECT. Conclusion Adequate levothyroxine treatment achieving and maintaining euthyroidism should be considered as therapy to lower autoantibodies and improve clinical outcome in patients with Hashimoto's thyroiditis and encephalopathy. PMID:24783049

  19. Detection of bacterial infection by a technetium-99m-labeled peptidoglycan aptamer.

    PubMed

    Ferreira, Iêda Mendes; de Sousa Lacerda, Camila Maria; Dos Santos, Sara Roberta; de Barros, André Luís Branco; Fernandes, Simone Odília; Cardoso, Valbert Nascimento; de Andrade, Antero Silva Ribeiro

    2017-09-01

    Nuclear medicine clinicians are still waiting for the optimal scintigraphic imaging agents capable of distinguishing between infection and inflammation, and between fungal and bacterial infections. Aptamers have several properties that make them suitable for molecular imaging. In the present study, a peptidoglycan aptamer (Antibac1) was labeled with 99m Tc and evaluated by biodistribution studies and scintigraphic imaging in infection-bearing mice. Labeling with 99m Tc was performed by the direct method and the complex stability was evaluated in saline, plasma and in the molar excess of cysteine. The biodistribution and scintigraphic imaging studies with the 99m Tc-Antibac1 were carried out in two different experimental infection models: Bacterial-infected mice (S. aureus) and fungal-infected mice (C. albicans). A 99m Tc radiolabeled library, consisting of oligonucleotides with random sequences, was used as a control for both models. Radiolabeling yields were superior to 90% and 99m Tc-Antibac1 was highly stable in presence of saline, plasma, and cysteine up to 6h. Scintigraphic images of S. aureus infected mice at 1.5 and 3.0h after 99m Tc-Antibac1 injection showed target to non-target ratios of 4.7±0.9 and 4.6±0.1, respectively. These values were statistically higher than those achieved for the 99m Tc-library at the same time frames (1.6±0.4 and 1.7±0.4, respectively). Noteworthy, 99m Tc-Antibac1 and 99m Tc-library showed similar low target to non-target ratios in the fungal-infected model: 2.0±0.3 and 2.0±0.6for 99m Tc-Antibac1 and 2.1±0.3 and 1.9 ± 0.6 for 99m Tc-library, at the same times. These findings suggest that the 99m Tc-Antibac1 is a feasible imaging probe to identify a bacterial infection focus. In addition, this radiolabeled aptamer seems to be suitable in distinguishing between bacterial and fungal infection. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  20. Liver function assessment using 99mTc-GSA single-photon emission computed tomography (SPECT)/CT fusion imaging in hilar bile duct cancer: A retrospective study.

    PubMed

    Sumiyoshi, Tatsuaki; Shima, Yasuo; Okabayashi, Takehiro; Kozuki, Akihito; Hata, Yasuhiro; Noda, Yoshihiro; Kouno, Michihiko; Miyagawa, Kazuyuki; Tokorodani, Ryotaro; Saisaka, Yuichi; Tokumaru, Teppei; Nakamura, Toshio; Morita, Sojiro

    2016-07-01

    The objective of this study was to determine the utility of Tc-99m-diethylenetriamine-penta-acetic acid-galactosyl human serum albumin ((99m)Tc-GSA) single-photon emission computed tomography (SPECT)/CT fusion imaging for posthepatectomy remnant liver function assessment in hilar bile duct cancer patients. Thirty hilar bile duct cancer patients who underwent major hepatectomy with extrahepatic bile duct resection were retrospectively analyzed. Indocyanine green plasma clearance rate (KICG) value and estimated KICG by (99m)Tc-GSA scintigraphy (KGSA) and volumetric and functional rates of future remnant liver by (99m)Tc-GSA SPECT/CT fusion imaging were used to evaluate preoperative whole liver function and posthepatectomy remnant liver function, respectively. Remnant (rem) KICG (= KICG × volumetric rate) and remKGSA (= KGSA × functional rate) were used to predict future remnant liver function; major hepatectomy was considered unsafe for values <0.05. The correlation of remKICG and remKGSA with posthepatectomy mortality and morbidity was determined. Although remKICG and remKGSA were not significantly different (median value: 0.071 vs 0.075), functional rates of future remnant liver were significantly higher than volumetric rates (median: 0.54 vs 0.46; P < .001). Hepatectomy was considered unsafe in 17% and 0% of patients using remKICG and remKGSA, respectively. Postoperative liver failure and mortality did not occur in the patients for whom hepatectomy was considered unsafe based on remKICG. remKGSA showed a stronger correlation with postoperative prothrombin time activity than remKICG. (99m)Tc-GSA SPECT/CT fusion imaging enables accurate assessment of future remnant liver function and suitability for hepatectomy in hilar bile duct cancer patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Liver perfusion imaging in patients with primary and metastatic liver malignancy: prospective comparison between 99mTc-MAA spect and dynamic CT perfusion.

    PubMed

    Reiner, Caecilia S; Goetti, Robert; Burger, Irene A; Fischer, Michael A; Frauenfelder, Thomas; Knuth, Alexander; Pfammatter, Thomas; Schaefer, Niklaus; Alkadhi, Hatem

    2012-05-01

    To prospectively analyze the correlation between parameters of liver perfusion from technetium99m-macroaggregates of albumin (99mTc-MAA) single photon emission computed tomography (SPECT) with those obtained from dynamic CT perfusion in patients with primary or metastatic liver malignancy. Twenty-five consecutive patients (11 women, 14 men; mean age 60.9 ± 10.8; range: 32-78 years) with primary (n = 5) or metastatic (n = 20) liver malignancy planned to undergo selective internal radiotherapy underwent dynamic contrast-enhanced CT liver perfusion imaging (four-dimensional spiral mode, scan range 14.8 cm, 15 scans, cycle time 3 seconds) and 99m)Tc-MAA SPECT after intraarterial injection of 180 MBq 99mTc-MAA on the same day. Data were evaluated by two blinded and independent readers for the parameters arterial liver perfusion (ALP), portal venous perfusion (PVP), and total liver perfusion (TLP) from CT, and the 99mTc-MAA uptake-ratio of tumors in relation to normal liver parenchyma from SPECT. Interreader agreements for quantitative perfusion parameters were high for dynamic CT (r = 0.90-0.98, each P < .01) and 99mTc -MAA SPECT (r = 0.91, P < .01). Significant correlation was found between 99mTc-MAA uptake ratio and ALP (r = 0.7, P < .01) in liver tumors. No significant correlation was found between 99mTc-MAA uptake ratio, PVP (r = -0.381, P = .081), and TLP (r = 0.039, P = .862). This study indicates that in patients with primary and metastatic liver malignancy, ALP obtained by dynamic CT liver perfusion significantly correlates with the 99mTc-MAA uptake ratio obtained by SPECT. Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.

  2. Differences in the intracellular processing of the radiolabel following the uptake of iodine-125- and technetium-99m-neogalactosyl albumin by the isolated perfused rat liver

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gore, S.; Morris, A.I.; Gilmore, I.T.

    1991-03-01

    Neogalactosyl albumin (NGA) is a synthetic ligand to the asialoglycoprotein receptor (hepatic binding protein), which has been proposed as a useful receptor binding radiopharmaceutical for the noninvasive assessment of liver function. We have compared the uptake and intracellular processing of iodine-125- (125I) and technetium-99m- ({sup 99m}Tc) NGA following its administration as a 1-min pulse (147 pmol) to the isolated perfused rat liver. Approximately 40% of a pulse of either {sup 125}I- or {sup 99m}Tc-NGA were taken up first pass by the liver. Of the {sup 125}I taken up by the liver, 82% was released after 15-20 min at the sinusoidalmore » pole of the hepatocyte, predominantly as small molecular weight metabolites. A further 8% of the {sup 125}I-associated radioactivity was secreted as intact NGA into bile by the non-lysosomal (direct) pathway while 6% remained in the liver 1 hr after the pulse. In contrast, of the {sup 99m}Tc taken up by the liver, only 4% reappeared in the perfusate while 40% was secreted into bile by the lysosomal (indirect) pathway and 55% remained in the liver 1 hr after the pulse. Since labeled metabolites of {sup 99m}Tc-NGA do not appear in plasma, this permits kinetic modeling with {sup 99m}Tc-NGA without correction for labeled metabolites. Thus, {sup 99m}Tc-NGA is an excellent candidate as a receptor-binding radiopharmaceutical.« less

  3. Tc-99m TRODAT uptake in an osteoid tumor of clivus.

    PubMed

    Taywade, Sameer; Tripathi, Madhavi; Tandon, Vivek; Das, Chandan Jyoti; Damle, Nishikant Avinash; Shamim, Shamim Ahmed; Thukral, Parul; Bal, Chandrasekhar

    2016-01-01

    Tc-99m TRODAT is cocaine analog and binds to the dopamine transporter in vivo . Tc-99m TRODAT single-photon emission computed tomography/computed tomography. (SPECT/CT) is useful for demonstrating presynaptic dopaminergic dysfunction in patients with Parkinsonism. However, few reports have shown extrastriatal uptake of Tc-99m TRODAT. We present the case of a 67-year-old male who underwent Tc-99m TRODAT SPECT/CT for evaluation of Parkinsonism. In addition to tracer binding in the striatum, tracer uptake was noted in an osteoid tumor of the clivus. Integrated SPECT/CT enabled precise localization and characterization of the extrastriatal site of tracer binding and emphasizes the importance of such coincidental findings.

  4. Sestamibi technetium-99m brain single-photon emission computed tomography to identify recurrent glioma in adults: 201 studies.

    PubMed

    Le Jeune, Florence Prigent; Dubois, François; Blond, Serge; Steinling, Marc

    2006-04-01

    In the follow-up of treated gliomas, CT and MRI can often not differentiate radionecrosis from recurrent tumor. The aim of this study was to assess the interest of functional imaging with (99m)Tc-MIBI SPECT in a large series of 201 examinations. MIBI SPECT were performed in 81 patients treated for brain gliomas. A MIBI uptake index was computed as the ratio of counts in the lesion to counts in the controlateral region. SPECT was compared to stereotactic biopsy in 14 cases, or in the others cases to imaging evolution or clinical course at 6 months after the last tomoscintigraphy Two hundred and one tomoscintigraphies were performed. One hundred and two scans were true positive, 82 scans were true negative. Six scans were false positive (corresponding to 3 patients): 2 patients with an inflammatory reaction after radiosurgery, 1 with no explanation up to now. Eleven scans were false negative (5 patients): 1 patient with a deep peri-ventricular lesion, 2 patients with no contrast enhancement on MRI, 2 patients with a temporal tumor. The sensitivity for tumor recurrence was 90%, specificity 91.5% and accuracy 90.5%. We studied separately low and high grade glioma: sensitivity for tumor recurrence was respectively 91% and 89%, specificity 100% and 83% and accuracy 95% and 87%. MIBI SPECT allowed the diagnose of anaplasic degenerence of low grade sometimes earlier than clinical (5 cases) or MRI signs (7 cases). Our results confirm the usefullness of MIBI SPECT in the follow-up of treated gliomas for the differential diagnosis between radiation necrosis and tumor recurrence.

  5. SPECT Imaging of Mice with 99mTc-Radiopharmaceuticals Obtained from 99Mo Produced by 100Mo(n,2n)99Mo and Fission of 235U

    NASA Astrophysics Data System (ADS)

    Hashimoto, Kazuyuki; Nagai, Yasuki; Kawabata, Masako; Sato, Nozomi; Hatsukawa, Yuichi; Saeki, Hideya; Motoishi, Shoji; Ohta, Masayuki; Konno, Chikara; Ochiai, Kentaro; Kawauchi, Yukimasa; Ohta, Akio; Shiina, Takayuki; Takeuchi, Nobuhiro; Ashino, Hiroki; Nakahara, Yuto

    2015-04-01

    The distribution of 99mTc-radiopharmaceutical in mouse was determined by single photon emission computed tomography (SPECT) for the first time using 99mTc, which was separated by thermochromatography from 99Mo produced via the 100Mo(n,2n)99Mo reaction with accelerator neutrons. The SPECT image was comparable to that obtained using the fission product 99Mo. Radionuclidic and radiochemical purities of the separated 99mTc and its aluminum concentration met the United States Pharmacopeia regulatory requirements for 99mTc from the fission product 99Mo. These results provide important evidence that the 99mTc-radiopharmaceutical formulated using the (n,2n) 99Mo can be a promising substitute for the fission product 99Mo. The current and forthcoming problem of ensuring a reliable and constant supply of 99Mo in Japan can be partially mitigated.

  6. A biokinetic model for systemic technetium in adult humans

    DOE PAGES

    Leggett, Richard Wayne; Giussani, Augusto

    2015-04-10

    The International Commission on Radiological Protection (ICRP) currently is updating its biokinetic and dosimetric models for internally deposited radionuclides. Technetium (Tc), the lightest element that exists only in radioactive form, has two important isotopes from the standpoint of potential risk to humans: the long-lived isotope 99Tm(T 1/2=2.1x10 5 y) is present in high concentration in nuclear waste, and the short-lived isotope 99mTc (T 1/2=6.02 h) is the most commonly used radionuclide in diagnostic nuclear medicine. This paper reviews data on the biological behavior of technetium and proposes a biokinetic model for systemic technetium in the adult human body formore » use in radiation protection. Compared with the ICRP s current occupational model for systemic technetium, the proposed model provides a more realistic description of the paths of movement of technetium in the body; provides greater consistency with experimental and medical data; and, for most radiosensitive organs, yields substantially different estimates of cumulative activity (total radioactive decays within the organ) following uptake of 99Tm or 99mTc to blood.« less

  7. In Vivo Imaging and Tracking of Technetium-99m Labeled Bone Marrow Mesenchymal Stem Cells in Equine Tendinopathy

    PubMed Central

    Dudhia, Jayesh; Becerra, Patricia; Valdés, Miguel A.; Neves, Francisco; Hartman, Neil G.; Smith, Roger K.W.

    2015-01-01

    Recent advances in the application of bone marrow mesenchymal stem cells (BMMSC) for the treatment of tendon and ligament injuries in the horse suggest improved outcome measures in both experimental and clinical studies. Although the BMMSC are implanted into the tendon lesion in large numbers (usually 10 - 20 million cells), only a relatively small number survive (<10%) although these can persist for up to 5 months after implantation. This appears to be a common observation in other species where BMMSC have been implanted into other tissues and it is important to understand when this loss occurs, how many survive the initial implantation process and whether the cells are cleared into other organs. Tracking the fate of the cells can be achieved by radiolabeling the BMMSC prior to implantation which allows non-invasive in vivo imaging of cell location and quantification of cell numbers. This protocol describes a cell labeling procedure that uses Technetium-99m (Tc-99m), and tracking of these cells following implantation into injured flexor tendons in horses. Tc-99m is a short-lived (t1/2 of 6.01 hr) isotope that emits gamma rays and can be internalized by cells in the presence of the lipophilic compound hexamethylpropyleneamine oxime (HMPAO). These properties make it ideal for use in nuclear medicine clinics for the diagnosis of many different diseases. The fate of the labeled cells can be followed in the short term (up to 36 hr) by gamma scintigraphy to quantify both the number of cells retained in the lesion and distribution of the cells into lungs, thyroid and other organs. This technique is adapted from the labeling of blood leukocytes and could be utilized to image implanted BMMSC in other organs. PMID:26709915

  8. Technetium-99m-Labeled Sulfadiazine: a Targeting Radiopharmaceutical for Scintigraphic Imaging of Infectious Foci Due To Escherichia coli in Mouse and Rabbit Models.

    PubMed

    Ahmed, Muhammad Tauqeer; Naqvi, Syed Ali Raza; Rasheed, Rashid; Zahoor, Ameer Fawad; Usman, Muhammad; Hussain, Zaib

    2017-09-01

    Bacterial infection is one of the vital reasons of morbidity and mortality, especially in developing countries. It appears silently without bothering the geological borders and imposes a grave threat to humanity. Nuclear medicine technique has an important role in helping early diagnosis of deep-seated infections. The aim of this study was to develop a new radiopharmaceutical 99m Tc-labeling sulfadiazine as an infection imaging agent. Radiolabeling of sulfadiazine with technetium-99m ( 99m Tc) was carried out using stannous tartrate as a reducing agent in the presence of gentistic acid at pH = 5. The quality control tests revealed ~98% labeling efficiency. Paper chromatographic (PC) and instant thin-layer chromatographic (ITLC) techniques were used to analyze radiochemical yield. Biodistribution and infection specificity of the radiotracer were performed with Escherichia coli (E. coli) infection-induced rats. Scintigraphy and glomerular filtration rate (GFR) study was performed in E. coli-infected rabbits. Scintigraphy indicated E. coli infection targeting potential of 99m Tc-SDZ, while biodistribution study showed minimal uptake of 99m Tc-SDZ in non-targeted tissues. The uptake in the kidneys was found 2.56 ± 0.06, 2.09 ± 0.10, and 1.68 ± 0.09% at 30 min, 1 h, and 4 h, respectively. The infected muscle (target) to non-infected muscle (non-target) ratio (T/NT) was found 4.49 ± 0.04, 6.78 ± 0.07, and 5.59 ± 0.08 at 30 min, 1 h, and 4 h, respectively.

  9. Comparison of technetium-99m sulfur colloid and technetium-99m albumin colloid labeled solid meals for gastric emptying studies.

    PubMed

    Taillefer, R; Douesnard, J M; Beauchamp, G; Guimond, J

    1987-08-01

    A Tc-99m albumin colloid (Tc-AC) kit has been introduced as an alternative to Tc-99m sulfur colloid (Tc-SC) for liver-spleen imaging. Since there is no need for boiling, the use of Tc-AC reduces preparation time and manipulation. Tc-SC is one of the most commonly used radiopharmaceuticals for the labeling of solid-phase markers in gastric emptying studies. In vitro studies were performed to evaluate the labeling efficiency and stability in hydrochloric acid and in human gastric juice of intracellularly labeled chicken liver and scrambled eggs labeled with Tc-SC and Tc-AC. Gastric emptying studies also were performed on 20 healthy volunteers with both Tc-SC and Tc-AC labeled scrambled egg sandwiches. There was no significant difference between Tc-SC and Tc-AC in the labeling efficiency of chicken liver (98% +/- 1% for Tc-SC, 96% +/- 2% for Tc-AC) and scrambled eggs (92% +/- 2% for Tc-SC, 91% +/- 3% for Tc-AC). However, both Tc-SC and Tc-AC labeled scrambled eggs showed a lower stability than chicken liver, particularly in human gastric juice. Gastric emptying curves from both meals in 20 normal subjects were also similar, with a mean half-emptying time of 85 +/- 13 minutes and 87 +/- 16 minutes for the meals containing Tc-SC and Tc-AC respectively. Tc-AC is a reliable alternative to Tc-SC as a radiotracer for solid-phase gastric emptying studies.

  10. Applications and interpretation of krypton 81m ventilation/technetium 99m macroaggregate perfusion lung scanning in childhood

    NASA Astrophysics Data System (ADS)

    Davies, Hugh Trevor Frimston

    Radionuclide ventilation perfusion lung scans now play an important part in the investigation of paediatric lung disease, providing a safe, noninvasive assessment of regional lung function in children with suspected pulmonary disease. In paediatric practice the most suitable radionuclides are Krypton 81m (Kr81m) and Technetium 99m (Tc99m), which are jointly used in the Kr81m ventilation/Tc99m macroaggregate perfusion lung scan (V/Q lung scan). The Kr81m ventilation scan involves a low radiation dose, requires little or no subject cooperation and because of the very short half life of Kr81m (13 seconds) the steady state image acquired during continuous inhalation of the radionuclide is considered to reflect regional distribution of ventilation. It is now the most important noninvasive method available for the investigation of the regional abnormalities of ventilation characteristic of many congenital and acquired paediatric respiratory diseases, such as diaphragmatic hernia, pulmonary sequestration, bronchopulmonary dysplasia, foreign body inhalation and bronchiectasis. It improves diagnostic accuracy, aids clinical decision making and is used to monitor the progress of disease and response to therapy. Theoretical analysis of the steady state Kr81m ventilation image suggests that it may only reflect regional ventilation when specific ventilation (ventilation per unit volume of lung) is within or below the normal adult range (1-3 L/L/min). At higher values such as those seen in neonates and infants (8-15 L/L/min) Kr81m activity may reflect regional lung volume rather than ventilation, a conclusion supported by the studies of Ciofetta et al. There is some controversy on this issue as animal studies have demonstrated that the Kr81m image reflects ventilation over a much wider range of specific ventilation (up to 13 L/L/min). A clinical study of sick infants and very young children is in agreement with this animal work and suggests that the steady state Kr81m image

  11. A prospective evaluation of preoperative localization by technetium-99m sestamibi scintigraphy and ultrasonography in primary hyperparathyroidism.

    PubMed

    Lo, Chung-Yau; Lang, Brian H; Chan, W F; Kung, Annie W C; Lam, Karen S L

    2007-02-01

    Ultrasonography (USG) and technetium-99m sestamibi (MIBI) scintigraphy are commonly used imaging modalities in the era of minimally invasive parathyroidectomy (MIP) for primary hyperparathyroidism (pHPT). However, their relative importance and actual contribution to MIP have not been prospectively assessed. A total of 100 consecutive pHPT patients planning for MIP were recruited. Both USG and MIBI findings were correlated with intraoperative findings and postoperative outcome. Clinicopathologic factors were examined for potential association with a correct localizing result. Thirty men and 70 women (age range 13 to 93 years [median 55.5]) were included in the study. The final pathology included 98 patients with solitary adenoma and 2 patients with multiglandular disease. The sensitivities, accuracies, and positive predicted values for USG and MIBI alone were 57% vs 89%, 56% vs 85%, and 97% vs 94%, respectively. Correctly localized adenomas were significantly heavier than incorrectly localized ones. MIBI is preferred over USG in pHPT patients planning for MIP. Weight of adenoma appeared to be the only clinicopathologic factor determining localization accuracy.

  12. Single-Photon Emission Computed Tomography/Computed Tomography Imaging in a Rabbit Model of Emphysema Reveals Ongoing Apoptosis In Vivo

    PubMed Central

    Goldklang, Monica P.; Tekabe, Yared; Zelonina, Tina; Trischler, Jordis; Xiao, Rui; Stearns, Kyle; Romanov, Alexander; Muzio, Valeria; Shiomi, Takayuki; Johnson, Lynne L.

    2016-01-01

    Evaluation of lung disease is limited by the inability to visualize ongoing pathological processes. Molecular imaging that targets cellular processes related to disease pathogenesis has the potential to assess disease activity over time to allow intervention before lung destruction. Because apoptosis is a critical component of lung damage in emphysema, a functional imaging approach was taken to determine if targeting apoptosis in a smoke exposure model would allow the quantification of early lung damage in vivo. Rabbits were exposed to cigarette smoke for 4 or 16 weeks and underwent single-photon emission computed tomography/computed tomography scanning using technetium-99m–rhAnnexin V-128. Imaging results were correlated with ex vivo tissue analysis to validate the presence of lung destruction and apoptosis. Lung computed tomography scans of long-term smoke–exposed rabbits exhibit anatomical similarities to human emphysema, with increased lung volumes compared with controls. Morphometry on lung tissue confirmed increased mean linear intercept and destructive index at 16 weeks of smoke exposure and compliance measurements documented physiological changes of emphysema. Tissue and lavage analysis displayed the hallmarks of smoke exposure, including increased tissue cellularity and protease activity. Technetium-99m–rhAnnexin V-128 single-photon emission computed tomography signal was increased after smoke exposure at 4 and 16 weeks, with confirmation of increased apoptosis through terminal deoxynucleotidyl transferase dUTP nick end labeling staining and increased tissue neutral sphingomyelinase activity in the tissue. These studies not only describe a novel emphysema model for use with future therapeutic applications, but, most importantly, also characterize a promising imaging modality that identifies ongoing destructive cellular processes within the lung. PMID:27483341

  13. Clinical usefulness of 99mTc-EDDA/HYNIC-TOC scintigraphy in oncological diagnostics: a preliminary communication.

    PubMed

    Płachcińska, Anna; Mikołajczak, Renata; Maecke, Helmut R; Młodkowska, Ewa; Kunert-Radek, Jolanta; Michalski, Andrzej; Rzeszutek, Katarzyna; Kozak, Józef; Kuśmierek, Jacek

    2003-10-01

    This study assessed the clinical usefulness of a new technetium-99m labelled somatostatin analogue from the standpoint of oncological diagnostics. The study group comprised 40 patients in whom malignant neoplasms (32 primary and 8 metastatic) had been diagnosed. Among the primary tumours there were 21 cases of lung cancer (2 small cell and 19 non-small cell), seven pituitary adenomas (five hormonally active and two inactive), one liposarcoma, two carcinoids and one breast carcinoma. The metastatic tumours consisted of three malignant melanomas, one phaeochromocytoma, one prostatic cancer, one leiomyosarcoma, one pancreatic carcinoma ectopically secreting ACTH and one carcinoid of the thymus. The radiopharmaceutical 99mTc-EDDA/HYNIC-Tyr3-octreotide was administered i.v. at an activity of 740-925 MBq. The imaging comprised a whole-body scan and a single-photon emission tomography acquisition. Positive scintigrams were obtained in all cases of small cell and non-small cell lung cancer, four out of five hormonally active pituitary adenomas, one out of two cases of carcinoid, the liposarcoma and the breast cancer. Neoplastic metastases were visualised in two out of three patients with melanoma and in patients with phaeochromocytoma, ACTH-secreting pancreatic carcinoma and thymic carcinoid. Scintigrams were negative in both hormonally inactive pituitary adenomas, in one case of metastatic malignant melanoma, in the leiomyosarcoma and in the case of metastasis from prostatic carcinoma. The results of this pilot study indicate that 99mTc-EDDA/HYNIC-TOC is a potentially useful radiopharmaceutical for imaging of a wide range of primary and metastatic tumours. Special attention should be paid to the successful imaging of all cases of non-small cell lung cancer.

  14. Human Fibronectin Extra-Domain B (EDB)-Specific Aptide (APTEDB) Radiolabelling with Technetium-99m as a Potent Targeted Tumour-Imaging Agent.

    PubMed

    Mohammadgholi, Mohsen; Sadeghzadeh, Nourollah; Erfani, Mostafa; Abediankenari, Saeid; Abedi, Seyed Mohammad; Emrarian, Iman; Jafari, Narjes; Behzadi, Ramezan

    2018-01-01

    Human fibronectin extra-domain B (EDB) is particularly expressed during angiogenesis progression. It is, thus, a promising marker of tumour growth. Aptides are a novel class of peptides with high-affinity binding to specific protein targets. APTEDB is an antagonist-like ligand that especially interacts with human fibronectin EDB. This study was the first attempt in which the hydrazinonicotinamide (HYNIC)-conjugated APTEDB was labelled with technetium-99m (99mTc) as an appropriate radiotracer and tricine/EDDA exchange labeling. Radiochemical purity, normal saline, and serum stability were evaluated by HPLC and radio-isotope TLC scanner. Other examinations, such as protein-binding calculation, dissociation radioligand binding assay, and partition coefficient constant determination, were also carried out. The cellular-specific binding of 99mTc- HYNIC-conjugated APTEDB was assessed in two EDB-positive (U87MG) and EDB-negative (U373MG) cell lines. Bio-distribution was investigated in normal mice as well as in U87MG and U373MG tumour-bearing mice. Eventually, the radiolabelled APTEDB was used for tumour imaging using planar SPECT. Radiolabelling was achieved with high purity (up to 97%) and accompanied by high solution (over 90% after overnight) and serum (80% after 2 hours) stability. The obtained cellular-specific binding ratio was greater than nine-fold. In-vivo experiments showed rapid blood clearance with mainly renal excretion and tumour uptake specificity (0.48±0.03% ID/g after 1h). The results of the imaging also confirmed considerable tumour uptake for EDB-positive cell line compared with the EDB-negative one. Aptides are considered to be a potent candidate for biopharmaceutical applications. They can be modified with imaging or therapeutic agents. This report shows the capability of 99mTc-HYNIC-APTEDB for human EDB-expressing tumours detection. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  15. The use of {sup 99m}Tc-Al{sub 2}O{sub 3} for detection of sentinel lymph nodes in breast cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sinilkin, I., E-mail: sinilkinig@oncology.tomsk.ru; Chernov, V.; Medvedeva, A.

    2016-08-02

    Purpose: to study the feasibility of using the new radiopharmaceutical based on the technetium-99m-labeled gamma-alumina for identification of sentinel lymph nodes (SLNs) in breast cancer patients. The study included two groups of breast cancer patients who underwent single photon emission computed tomography (SPECT) and intraoperaive gamma probe identification of sentinel lymph nodes (SLNs). To identify SLNs, the day before surgery Group I patients (n = 34) were injected with radioactive {sup 99m}Tc-Al{sub 2}O{sub 3}, and Group II patients (n = 30) received {sup 99m}Tc-labeled phytate colloid. A total of 37 SLNs were detected in Group I patients. The number ofmore » identified SLNs per patient ranged from 1 to 2 (the average number of identified SLNs was 1.08). Axillary lymph nodes were the most common site of SLN localization. 18 hours after {sup 99m}Tc-Al{sub 2}O{sub 3} injection, the percentage of its accumulation in the SLN was 7–11% (of the counts in the injection site) by SPECT and 17–31% by gamma probe detection. In Group II SLNs were detected in 27 patients. 18 hours after injection of the phytate colloid the percentage of its accumulation in the SLN was 1.5–2% out of the counts in the injection site by SPECT and 4–7% by gamma probe. The new radiopharmaceutical based on the {sup 99m}Tc-Al{sub 2}O{sub 3} demonstrates high accumulation in SLNs without redistribution through the entire lymphatic basin. The sensitivity and specificity of {sup 99m}Tc-Al{sub 2}O{sub 3} were 100% for both SPECT and intraoperative gamma probe identification.« less

  16. /sup 99m/Tc-IDA imaging in the differential diagnosis of acute cholecystitis and acute pancreatitis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fonseca, C.; Greenberg, D.; Rosenthall, L.

    1979-02-01

    Technetium-/sup 99m/-labelled dimethly-acetanilide-iminodiacetic acid (/sup 99m/Tc-IDA) hepato-biliary imaging was evaluated for its efficacy in distinguishing acute cholecystitis from acute pancreatitis. In a retrospective review, gallbladders were demonstrated by /sup 99m/Tc-IDA in 13 of 15 patients (87%) with acute pancreatitis. This is significantly higher than reports on the frequency of gallbladder filling with oral and intravenous cholangiography in the presence of acute cholecystitis.

  17. Technetium 99m pertechnetate scans in congenital hypothyroidism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bauman, R.A.; Bode, H.H.; Hayek, A.

    1976-08-01

    Goiters are rarely palpable in infants with congenital hypothyroidism except in the case of maternal ingestion of iodide. The presence or absence of glandular tissue is, however, important for genetic and prognostic counseling and for acceleration of diagnosis in other affected siblings. The detection of thyroid tissue by /sup 99m/Tc pertechnetate scans in a significant number of our patients heretofore considered athyreotic establishes that physical findings and traditional laboratory data are not adequate to determine whether or not thyroid tissue is present.

  18. Imaging of glutathione localization in brain with technetium-99M meso-hexamethyl propyleneamine oxime

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sasaki, T.; Toyama, H.; Oda, K.

    1995-05-01

    Previous studies have shown decreasing [Tc-99m] meso-HM-PAO uptake in accordance with glutathione (GSH) content in diethyl, maleate (DEM) treated mice brain. In order to elucidate the retention mechanism of [Tc-99m] HM-PAO in brain and to visualize the regional localization of GSH in the brain with [Tc-99m] meso-HM-PAO, the relationship between the tissue GSH content and uptake of [Tc-99m] meso-HM-PAO was studied in rats and rabbits. Increasing pre-load of DEM (550 mg/kg body weight), an agent to reduce GSH content by glutathione transferase, led to a decrease in GSH (control 1.972{plus_minus}0.017 vs DEM 1.138{plus_minus}0.106 mM) and uptake of [Tc-99m] meso-HM-PAO tomore » half of the control in the rat brain (control 0.281{plus_minus}0.024 vs DEM 0.153 {plus_minus} 0.009 % dose/g). On the other hand, the DEM did not decrease GSH or the uptake of [Tc-99m] meso-HM-PAO in the rabbit brain, in which glutathione transferase activity is very low. These results were also demonstrated by images with pin-hole collimated gamma camera. The uptake of [Tc-99m] meso showed variations in the regional distribution, but the d,l-isomer was uniform. [Tc-99m] meso-HM-PAO uptake was well correlated with GSH content in mice brain regions (r=0.800, p<0.02), whereas [Tc-99m]d,l-HM-PAO was not (r=0.017, p>0.5). Both [Tc-99m] mesa HM-PAO uptake and GSH content were especially high at cerebellum (Uptake: 2.598{plus_minus}0.256 % dose/g. GSH: 2.372{plus_minus}0.107 mM) as compared to other areas (Uptake;cerebral cortex 1.797{plus_minus}0.100 brain stem 1.607 {plus_minus}0.112 % dose/g. GSH: cerebral cortex 1.635{plus_minus}0.142 brain stem 1.478{plus_minus}0.141 mM).« less

  19. Room temperature single photon generation at 1. 5 μ m from covalent dopant states of carbon nanotubes

    NASA Astrophysics Data System (ADS)

    Htoonb, Han; He, Xiaowei; Hartmann, Nicolai; Ma, Xuedan; Doorn, Stephen; CenterIntegrated Nanotechnologies, Los Alamos National Laboratory Team

    Recent demonstration that oxygen dopant states covalently attached to the single-walled carbon nanotubes (SWCNTs) are capable of emitting single photons at room-T (RT) opens the possibility of building room-T electrically-driven single photon sources for quantum communication applications. The RT single photon generation was not observed only at wavelength beyond 1.3 μ m. Here in this work we demonstrate RT single photon generation at 1. 5 μ m from diazonium dopant states of (10,3) nanotubes.

  20. Sentinel lymph node mapping in melanoma with technetium-99m dextran.

    PubMed

    Neubauer, S; Mena, I; Iglesis, R; Schwartz, R; Acevedo, J C; Leon, A; Gomez, L

    2001-06-01

    The aim of this work is to evaluate the capability of Tc99m B Dextran as a lymphoscintigraphic agent in the detection of the sentinel node in skin lesions. Forty-one patients with melanomas (39) and Merkel cell tumors (2) had perilesional intradermal injection of Tc99m-Dextran 2 hours before surgery. Serial gamma camera images and a handheld gamma probe were used to direct sentinel node biopsy. In 39/41 patients, lymph channels and 52 sentinel nodes (one to three sentinel nodes/patient) could be visualized. In one patient, with a dorsal melanoma, no lymph channels or lymph nodes could be demonstrated on the images and only minimal radioactivity was found in the regional nodes with the probe. Another patient with a facial lesion failed to demonstrate lymph channels or nodes. No adverse reactions were observed. Tc99m-Dextran provided good definition of lymph channels and sentinel node localization, without the risks related to the use of potentially hazardous labeled materials of biological origin.

  1. Single-Atom Single-Photon Quantum Interface

    NASA Astrophysics Data System (ADS)

    Moehring, David; Bochmann, Joerg; Muecke, Martin; Specht, Holger; Weber, Bernhard; Wilk, Tatjana; Rempe, Gerhard

    2008-05-01

    By combining atom trapping techniques and cavity cooling schemes we are able to trap a single neutral atom inside a high-finesse cavity for several tens of seconds. We show that our coupled atom-cavity system can be used to generate single photons in a controlled way. With our long trapping times and high single-photon production efficiency, the non-classical properties of the emitted light can be shown in the photon correlations of a single atom. In a similar atom-cavity setup, we investigate the interface between atoms and photons by entangling a single atom with a single photon emitted into the cavity and by further mapping the quantum state of the atom onto a second single photon. These schemes are intrinsically deterministic and establish the basic element required to realize a distributed quantum network with individual atoms at rest as quantum memories and single flying photons as quantum messengers. This work was supported by the Deutsche Forschungsgemeinschaft, and the European Union SCALA and CONQUEST programs. D. L. M. acknowledges support from the Alexander von Humboldt Foundation.

  2. Myocardial imaging with 99mTc-Tetrofosmin: Influence of post-stress acquisition time, regional radiotracer uptake, and wall motion abnormalities on the clinical result.

    PubMed

    Giorgetti, Assuero; Kusch, Annette; Casagranda, Mirta; Tagliavia, Irene D'Aragona; Marzullo, Paolo

    2010-04-01

    We previously demonstrated that early (15', T1) post-stress myocardial imaging with Tetrofosmin could be more accurate than standard acquisitions (45', T2) in identifying coronary artery disease. To clarify this phenomenon, 120 subjects (age 61 +/- 10 years) with both T1 and T2 scans were divided into Group 1 (53/120 pts) with more ischemia at T1 vs T2 imaging (T1-T2SDS > or = 3); Group 2 (67/120 pts) with similar results (T1-T2SDS < or = 2). Myocardial areas were categorized as control nonischemic, ischemic, and scarred on the basis of perfusion/contraction properties and coronary anatomy. In each area, regional myocardial count statistic and semiquantitative wall motion/thickening values were obtained. Analysis of T1 and T2 post-stress myocardial counts demonstrated a significant Tetrofosmin wash-out rate that was higher in Group 1 control nonischemic regions (15 +/- 8% vs 13.6 +/- 9.6%, P < .02), significantly lower in Group 1 ischemic regions (7 +/- 10% vs 12.2 +/- 9.5%, P < .0001), and comparable between scarred areas of the two groups (P = NS). Delta post-stress wall thickening (T1-T2) was lower in Group 1 ischemic regions (-4.5 +/- 9.15% vs -1.90 +/- 7.0%, P < .001) and comparable in both control nonischemic and scarred areas of the two groups (P = NS). The clinical result of Tetrofosmin gated-SPECT can be influenced by the post-stress acquisition time because of ischemic-induced regional wall thickening abnormalities and the existence of a differential radiotracer myocardial wash-out.

  3. Myocardial uptake and kinetic properties of technetium-99m-Q3 in dogs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gerson, M.C.; Millard, R.W.; McGoron, A.J.

    1994-10-01

    We postulated that {sup 99m}Tc-Q3, a cationic imaging agent, produces myocardial activity related to myocardial blood flow during myocardial ischemia and pharmacologic coronary artery vasodilation, and shows little or no myocardial redistribution over 4 hr after intravenous injection. In six Group 1 dogs, the chest was opened, the left circumflex coronary artery was acutely ligated, and dipyridamole (0.32, 0.56 or 0.84 mg/kg) was infused into the right atrium, followed by 10 mCi of {sup 99m}Tc-Q3. Myocardial blood flow was measured by radiolabeled microspheres. The animals were euthanized and 357 myocardial samples were assayed in a well counter for {sup 99m}Tcmore » activity. One week later, radiolabeled microsphere activity was counted and myocardial blood flow calculated. In nine Group 2 dogs, a variable occluder was placed around the left circumflex coronary artery and an ischemic level of circumflex blood flow was maintained constant over 4 hr as measured by an ultrasonic flow meter. Dipyridamole (0.56 mg/kg) was then infused into the right atrium followed by 10mCi of {sup 99m}Tc-Q3. Gamma camera images were acquired at 5, 15, 30, 60, 120 and 240 min following k{sup 99m}Tc-Q3 injection. Microsphere blood flow and endocardial biopsies (n - 6 dogs) were performed at 30, 60, 120 and 240 min following {sup 99m}TcQ3 injection. 31 refs., 9 figs., 1 tab.« less

  4. 99mTc-N4-[Tyr3]Octreotate Versus 99mTc-EDDA/HYNIC-[Tyr3]Octreotide: an intrapatient comparison of two novel Technetium-99m labeled tracers for somatostatin receptor scintigraphy.

    PubMed

    Gabriel, Michael; Decristoforo, Clemens; Maina, Theodosia; Nock, Berthold; vonGuggenberg, Elisabeth; Cordopatis, Paul; Moncayo, Roy

    2004-02-01

    Tetraamine-[Tyr3]octreotate (Demotate) is a somatostatin (SST) analogue that can be easily labeled with 99mTc at high specific activities and showed promising preclinical properties for SST receptor scintigraphy. This study reports on the first intra-patient comparison of 99mTc-Demotate and another 99mTc-labeled SST analogue, 99mTc-EDDA/HYNIC-TOC (HYNIC-TOC). Five patients with carcinoid tumors (n = 2) and endocrine pancreatic tumors (n = 3) were investigated with both radiopharmaceuticals. 99mTc-Demotate rapidly visualized somatostatin receptor positive tumors as early as 15 minutes post-injection (p.i.) with maximum tumor uptake and tumor/organ ratios already 1 hour p.i. Organs of predominant physiological uptake were the spleen and the kidneys with no intestinal excretion detectable up to 24 hours. 99mTc-Demotate exhibited faster pharmacokinetic properties compared to HYNIC-TOC. Tumor/organ ratios at equivalent time points were higher or comparable for 99mTc-Demotate in three patients with a matching scan result. Equivocal findings were observed in two patients, i.e. comparable uptake behavior in larger lesions with differences in smaller ones. 99mTc-Demotate is a promising agent for somatostatin receptor scintigraphy providing images of excellent quality as early as 1 hour after injection.

  5. Significance of functional hepatic resection rate calculated using 3D CT/(99m)Tc-galactosyl human serum albumin single-photon emission computed tomography fusion imaging.

    PubMed

    Tsuruga, Yosuke; Kamiyama, Toshiya; Kamachi, Hirofumi; Shimada, Shingo; Wakayama, Kenji; Orimo, Tatsuya; Kakisaka, Tatsuhiko; Yokoo, Hideki; Taketomi, Akinobu

    2016-05-07

    To evaluate the usefulness of the functional hepatic resection rate (FHRR) calculated using 3D computed tomography (CT)/(99m)Tc-galactosyl-human serum albumin (GSA) single-photon emission computed tomography (SPECT) fusion imaging for surgical decision making. We enrolled 57 patients who underwent bi- or trisectionectomy at our institution between October 2013 and March 2015. Of these, 26 patients presented with hepatocellular carcinoma, 12 with hilar cholangiocarcinoma, six with intrahepatic cholangiocarcinoma, four with liver metastasis, and nine with other diseases. All patients preoperatively underwent three-phase dynamic multidetector CT and (99m)Tc-GSA scintigraphy. We compared the parenchymal hepatic resection rate (PHRR) with the FHRR, which was defined as the resection volume counts per total liver volume counts on 3D CT/(99m)Tc-GSA SPECT fusion images. In total, 50 patients underwent bisectionectomy and seven underwent trisectionectomy. Biliary reconstruction was performed in 15 patients, including hepatopancreatoduodenectomy in two. FHRR and PHRR were 38.6 ± 19.9 and 44.5 ± 16.0, respectively; FHRR was strongly correlated with PHRR. The regression coefficient for FHRR on PHRR was 1.16 (P < 0.0001). The ratio of FHRR to PHRR for patients with preoperative therapies (transcatheter arterial chemoembolization, radiation, radiofrequency ablation, etc.), large tumors with a volume of > 1000 mL, and/or macroscopic vascular invasion was significantly smaller than that for patients without these factors (0.73 ± 0.19 vs 0.82 ± 0.18, P < 0.05). Postoperative hyperbilirubinemia was observed in six patients. Major morbidities (Clavien-Dindo grade ≥ 3) occurred in 17 patients (29.8%). There was no case of surgery-related death. Our results suggest that FHRR is an important deciding factor for major hepatectomy, because FHRR and PHRR may be discrepant owing to insufficient hepatic inflow and congestion in patients with preoperative therapies, macroscopic vascular

  6. Evaluation of changes in perfusion defect and left ventricular systolic function using Tc-99m Tetrofosmin single photon emission computed tomography over 3 month period in patients of Acute Myocardial Infarction undergoing primary angioplasty.

    PubMed

    Kumar, Avs Anil; Kumar, P G; Swami, Ajay; Dinker, Yateendra

    2018-01-01

    After a primary transluminal coronary angioplasty (PTCA) following AMI (acute myocardial infarction), the perfusion defect and LV (left ventricular) function recover/change over a period of time. The analysis immediately after the procedure may not be true depiction of the exact success of the procedure. There is varying and scanty information available on the natural course of changes in these parameters after a successful PTCA. We hypothesized that majority of change occurs at 3-4 month period. Hence, we undertook this study on the natural course of recovery/changes occurring in perfusion defect size and LV function in first 3 months after primary angioplasty MATERIAL AND METHODS: 30 consecutive cases of first AMI who were taken up for Primary angioplasty were enrolled into the study. Resting MPI(Myocardial perfusion imaging) was done within 24-72 hrs of admission using Tc-99m-Tetrofosmin and after 10-14 weeks. Analysis of LVEF (left ventricular ejection fraction), summed segmental score and extent of perfusion defect was done. Images were processed using autocardiac software of emory tool box and quantification was done using QPS (quantitative perfusion SPECT) and QGS (qualitative perfusion SPECT) softwares. 20 segment scoring method was used for quantification on bull's eye images. Student t test (two tailed, dependent) was used to find the significance of study parameters on continuous scale within each group. Effect size was computed to find the effect. Pearson correlation between perfusion defect and LVEF was performed at acute stage and after 10-14 weeks. The average acute perfusion defect extent was 19.76 ± 12.89% which after 3months became 16.79 ± 12.61%. The summed segmental score changed from 14.31 ± 10.58 to 11.38 ± 10.03 and LVEF improved from 48.40 ± 13.15% to 53.37 ± 12.8%. There was significant improvement in LVEF from acute setting to 10-14 weeks (p = 0.001). There was significant lowering of summed score (p = 0.007). Perfusion defect size

  7. Radioactive excretion in human milk following administration of /sup 99m/Tc macroaggregated albumin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pittard, W.B.; Merkatz, R.; Fletcher, B.D.

    Albumin-tagged sodium pertechnetate (technetium) is routinely used in nuclear medicine for scanning procedures of the lung. The rate of excretion of this radionuclide into breast milk and the resultant potential radiation hazard to the nursing infant have received little attention. Therefore the milk from a nursing mother who required a lung scan because of suspected pulmonary emboli using an intravenous injection of 4 mCi of /sup 99m/Tc macroaggregated human serum albumin was monitored. Albumin tagging severely limited the entrance of technetium into her milk and the radioactivity of the milk returned to base line by 24 hours. A total ofmore » 2.02 muCi of technetium was measured in the 24-hour milk collection after technetium injection and 94% of this amount was excreted by 15.5 hours. This amount of technetium administered orally to a newborn would deliver a total body radiation dose of .3 mrad. Therefore, an infant would receive trivial doses of radiation if breast-feeding were resumed 15.5 hours after administration of the radionuclide to the mother and nursing can clearly be resumed safely 24 hours after injection.« less

  8. 1.5- μm single photon counting using polarization-independent up-conversion detector

    NASA Astrophysics Data System (ADS)

    Takesue, Hiroki; Diamanti, Eleni; Langrock, Carsten; Fejer, M. M.; Yamamoto, Yoshihisa

    2006-12-01

    We report a 1.5- μm band polarization independent single photon detector based on frequency up-conversion in periodically poled lithium niobate (PPLN) waveguides. To overcome the polarization dependence of the PPLN waveguides, we employed a polarization diversity configuration composed of two up-conversion detectors connected with a polarization beam splitter. We experimentally confirmed polarization independent single photon counting using our detector. We undertook a proof-of-principle differential phase shift quantum key distribution experiment using the detector, and confirmed that the sifted key rate and error rate remained stable when the polarization state was changed during single photon transmission.

  9. The study of interaction of modified fatty acid with {sup 99m}Tc in alcoholic media

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Skuridin, V. S.; Stasyuk, E. S.; Varlamova, N. V.

    2016-08-02

    The paper presents the results of laboratory research aimed at the development of methods of synthesis of new radiodiagnostic agents based on modified fatty acid labelled with technetium-99m intended for scintigraphic evaluation of myocardial metabolism. In particular, the interaction of substance with {sup 99m}Tc in alcoholic media and the use of ethanol as solvent in the synthesis of the radiopharmaceutical were studied.

  10. Time course evaluation of myocardial perfusion after reperfusion therapy by 99mTc-tetrofosmin SPECT in patients with acute myocardial infarction.

    PubMed

    Tanaka, R; Nakamura, T

    2001-09-01

    Myocardial perfusion imaging with 99mTc-labeled agents immediately after reperfusion therapy can underestimate myocardial salvage. It is also conceivable that delayed imaging is useful for assessing the risk area. However, to our knowledge, very few studies have sequentially evaluated these image changes. We conducted 99mTc-tetrofosmin (TF) and 123I-beta-methyl-p-iodophenylpentadecanoic acid (BMIPP) SPECT before and after reperfusion to treat acute myocardial infarction and quantified changes in TF myocardial accumulation and reverse redistribution. Seventeen patients with a first myocardial infarction underwent successful reperfusion. We examined SPECT images obtained at the onset (preimage), those acquired 30 min (early image) and 6 h (delayed image) after TF injection, and images acquired 1, 4, 7, and 20 d after reperfusion (post-1-d, post-4-d, post-7-d, and post-20-d image, respectively). We also examined BMIPP SPECT images after 7 +/- 1.8 d (BMIPP image). Polar maps were divided into 48 segments to calculate percentage uptake, and time course changes in segment numbers below 60% were observed as abnormal area. Moreover, cardiac function was analyzed by gated TF SPECT on 1 and 20 d after reperfusion. In reference to the abnormal area on the early images, the post-1-d image was significantly improved compared with the preimage (P < 0.01) as was the post-7-d image compared with the post-1-d and post-4-d images (P < 0.05, respectively). However, post-20-d and post-7-d images did not significantly differ. Therefore, the improvement in myocardial accumulation reached a plateau 7 d after reperfusion. On the other hand, the abnormal area on the delayed images was significantly greater (P < 0.01) compared with that on the early images from 4 to 20 d after reperfusion, as the value was essentially constant. The correlations of the abnormal area between the preimage and the post-7-d delayed image, the preimage and the BMIPP image, and the post-7-d delayed image and the

  11. Comparison of early myocardial technetium-99m pyrophosphate uptake to early peaking of creatine kinase and creatine kinase-MB as indicators of early reperfusion in acute myocardial infarction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kondo, M.; Yuzuki, Y.; Arai, H.

    1987-10-01

    The value of technetium-99m pyrophosphate (Tc-99m-PYP) scintigraphy as an indicator of reperfusion 2.8 to 8 hours after the onset of symptoms of acute myocardial infarction was compared with the value of early peak creatine kinase (CK) and CK-MB release within 16 hours after the onset of symptoms. In 29 patients who received thrombolytic therapy, recanalization was seen (group 1) and in 7 it was not (group 2). In 23 patients (79%) in group 1 scintigraphic findings were positive and in all 7 in group 2 they were negative. In 15 patients (52%) in group 1 and 1 patient (14%) inmore » group 2, CK reached its peak level within 16 hours. In 20 patients (69%) in group 1 and 3 (43%) in group 2 the CK-MB level reached a peak within 16 hours. The sensitivity, specificity and predictive accuracy of positive results of early Tc-99m-PYP scintigraphy in predicting the reperfusion were 79%, 100% and 83%. These values are significantly higher than or similar to those of early peaking of CK and CK-MB release. In contrast to measurements of enzyme release, reperfusion data for Tc-99m-PYP scintigraphy are available immediately after thrombolytic therapy. Therefore, early Tc-99m-PYP scintigraphy (3 to 8 hours after onset of symptoms) is valuable as a noninvasive technique for early diagnosis of reperfusion.« less

  12. Non-Q-wave myocardial infarction: impaired myocardial energy metabolism in regions with reduced 99mTc-MIBI accumulation.

    PubMed

    Moka, D; Baer, F M; Theissen, P; Schneider, C A; Dietlein, M; Erdmann, E; Schicha, H

    2001-05-01

    Reduced regional technetium-99m methoxyisobutylisonitrile (99mTc-MIBI) accumulation in patients with chronic non-Q-wave infarction (NQWI) but without significant coronary artery stenosis indicates non-transmural damage of the myocardial wall. The aim of this study was to characterise cardiac energy metabolism after NQWI using phosphorus-31 magnetic resonance spectroscopy (31P-MRS) and to compare the biochemical remodelling with changes in regional 99mTc-MIBI uptake and with morphological and functional parameters assessed by magnetic resonance imaging (MRI). Fifteen patients with a history of NQWI, exclusion of significant coronary artery stenosis (<50% diameter stenosis) and hypokinesia of the anterior wall (group A) were examined with 31P-MRS to study the effects of NQWI on myocardial energy metabolism. Spectroscopic measurements were performed in the infarct-related myocardial region. Corresponding gradient-echo MR images and myocardial 99mTc-MIBI single-photon emission tomography images were acquired for exact localisation of the infarct region. All examinations were performed at rest under anti-ischaemic medication. Data were compared with those of patients in whom coronary artery disease had been excluded by angiography (group B, n=10). All patients of group A displayed anterior wall hypokinesia in the infarcted area on both ventriculography and MRI, with a reduced myocardial accumulation of 99mTc-MIBI (66.3%+/-11.8% vs 95.6%+/-2.2% in group B). The mean wall thickness during the complete cardiac cycle (9.5+/-1.8 mm vs 13.1+/-1.1 mm in group B, P<0.001), the systolic wall thickening (2.6+/-1.4 mm vs 5.8+/-1.5 mm in group B, P<0.01) and the phosphocreatine/adenosine triphosphate ratio (1.12+/-0.22 vs 1.74+/-0.23 in group B, P<0.01) in the hypokinetic area were all significantly reduced. It is concluded that persisting hypokinetic myocardium after NQWI combined with reduced myocellular uptake of 99mTc-MIBI displays a reduced PCr/ATP ratio. Our results indicate

  13. 99 mTc-MIBI washout as a complementary factor in the evaluation of idiopathic dilated cardiomyopathy (IDCM) using myocardial perfusion imaging.

    PubMed

    Shiroodi, Mohammad Kazem; Shafiei, Babak; Baharfard, Nastaran; Gheidari, Mohammad Esmail; Nazari, Babak; Pirayesh, Elaheh; Kiasat, Ali; Hoseinzadeh, Samaneh; Hashemi, Abolghassem; Akbarzadeh, Mohammad Ali; Javadi, Hamid; Nabipour, Iraj; Assadi, Majid

    2012-01-01

    Rapid technetium-99 m methoxyisobutylisonitrile (99 mTc-MIBI) washout has been shown to occur in impaired myocardia. This study is based on the hypothesis that scintigraphy can be applied to calculate the myocardial 99 mTc-MIBI washout rate (WR) to diagnose and evaluate heart failure severity and other left ventricular functional parameters specifically in idiopathic dilated cardiomyopathy (IDCM) patients. Patients with IDCMP (n = 17; 52.65 ± 11.47 years) and normal subjects (n = 6; 49.67 ± 10.15 years) were intravenously administered 99 mTc-hexakis-2-methoxyisobutylisonitrile (99 mTc-MIBI). Next, early and delayed planar data were acquired (at 3.5-h intervals), and electrocardiogram (ECG)-gated myocardial perfusion single photon emission computed tomography (SPECT) was performed. The 99 mTc-MIBI WR was calculated using early and delayed planar images. Left ventricular functional parameters were also analyzed using quantitative gated SPECT (QGS) data. In target group, myocardial WRs (29.13 ± 6.68%) were significantly higher than those of control subjects (14.17 ± 3.31%; P < 0.001). The 99 mTc-MIBI WR increased with the increasing severity of the NYHA functional class (23.16 ± 1.72% for class I, 30.25 ± 0.95% for class II, 32.60 ± 6.73% for class III, and 37.50 ± 7.77% for class IV; P = 0.02). The WR was positively correlated with the end-diastolic volume (EDV) index (r (2) = 0.216; β = 0.464; P = 0.02 [ml/m(2)], the end-systolic volume (ESV) index (r (2) = 0.234; β = 0.484; P = 0.01 [ml/m(2)]), the summed motion score (SMS) (r (2) = 0.544; β = 0.738; P = 0.00), and the summed thickening score (STS) (r (2) = 0.656; β = 0.810; P = 0.00); it was negatively correlated with the left ventricular ejection fraction (LVEF) (r (2) = 0.679; β = -0.824; P = 0.00). It can be concluded that 99 mTc-MIBI scintigraphy might be a valuable molecular imaging tool for the diagnosis and evaluation of myocardial damage or dysfunction severity.

  14. 99mTc: Labeling Chemistry and Labeled Compounds

    NASA Astrophysics Data System (ADS)

    Alberto, R.; Abram, U.

    This chapter reviews the radiopharmaceutical chemistry of technetium related to the synthesis of perfusion agents and to the labeling of receptor-binding biomolecules. To understand the limitations of technetium chemistry imposed by future application of the complexes in nuclear medicine, an introductory section analyzes the compulsory requirements to be considered when facing the incentive of introducing a novel radiopharmaceutical into the market. Requirements from chemistry, routine application, and market are discussed. In a subsequent section, commercially available 99mTc-based radiopharmaceuticals are treated. It covers the complexes in use for imaging the most important target organs such as heart, brain, or kidney. The commercially available radiopharmaceuticals fulfill the requirements outlined earlier and are discussed with this background. In a following section, the properties and perspectives of the different generations of radiopharmaceuticals are described in a general way, covering characteristics for perfusion agents and for receptor-specific molecules. Technetium chemistry for the synthesis of perfusion agents and the different labeling approaches for target-specific biomolecules are summarized. The review comprises a general introduction to the common approaches currently in use, employing the N x S4-x , [3+1] and 2-hydrazino-nicotinicacid (HYNIC) method as well as more recent strategies such as the carbonyl and the TcN approach. Direct labeling without the need of a bifunctional chelator is briefly reviewed as well. More particularly, recent developments in the labeling of concrete targeting molecules, the second generation of radiopharmaceuticals, is then discussed and prominent examples with antibodies/peptides, neuroreceptor targeting small molecules, myocardial imaging agents, vitamins, thymidine, and complexes relevant to multidrug resistance are given. In addition, a new approach toward peptide drug development is described. The section

  15. Synthesis, Characterization and Biological Studies of 99mTc and 188Re Peptides

    NASA Astrophysics Data System (ADS)

    Sanders, Vanessa

    Radiopharmaceuticals are very powerful diagnostic tools for evaluation of a host of medical conditions. These drugs are labeled with radioactive isotopes, which are utilized to create pictures of areas of interest through absorption of the drug. They are currently in high demand due to their ability to image areas that traditional imaging devices cannot. The radioisotope 99mTc, with a half-life of 6.01 hours and a 140 keV gamma emission, is central to many radiopharmaceutical compounds. This isotope is easily obtained from a 99Mo-99mTc generator, through beta decay and column chromatography separations. Very little technetium, less than 6 ng, is needed to label the pharmaceuticals for use in-vivo. Another radioisotope 188Re is also important due to its ability to be used for therapy while being tracked throughout the body. Radiotherapy gives radiopharmaceuticals a huge advantage by their ability to destroy rapidly growing cells. One of the main reasons there is interest in rhenium pharmaceuticals is the chemical similarity between it and technetium. The 188Re isotope also has a considerably short half-life of approximately 17 hours and has emission energy of 155 keV. The 188Re isotope is separated from 188W-188Re generator, analogously to the 99Mo-99mTc generator. The ligand used in this work is a pentapepetide macrocyclic ligand. This ligand, KYCAR (lysyl-tyrosyl-cystyl-alanyl-arginine), has been designed as a potential chelating ligand for imaging and therapeutic in vivo agents. Ligands are chosen based on their in-situ biological behavior, and are used in the complexation with technetium and rhenium. Understanding and exploiting technetium and rhenium chemistry can provide insight into the reaction mechanisms and coordination chemistry of these compounds. The exploration of various oxidation states as a function of the ligands used and the reaction conditions can help develop novel radiopharmaceuticals. The investigations of the manipulation of oxidation states

  16. Simultaneous acquisition of (99m)Tc- and (123)I-labeled radiotracers using a preclinical SPECT scanner with CZT detectors.

    PubMed

    Kobayashi, Masato; Matsunari, Ichiro; Nishi, Kodai; Mizutani, Asuka; Miyazaki, Yoshiharu; Ogai, Kazuhiro; Sugama, Jyunko; Shiba, Kazuhiro; Kawai, Keiichi; Kinuya, Seigo

    2016-05-01

    Simultaneous acquisition of (99m)Tc and (123)I was evaluated using a preclinical SPECT scanner with cadmium zinc telluride (CZT)-based detectors. 10-ml cylindrical syringes contained about 37 MBq (99m)Tc-tetrofosmin ((99m)Tc-TF) or 37 MBq (123)I-15-(p-iodophenyl)-3R,S-methyl pentadecanoic acid ((123)I-BMIPP) were used to assess the relationship between these SPECT radioactive counts and radioactivity. Two 10-ml syringes contained 100 or 300 MBq (99m)Tc-TF and 100 MBq (123)I-BMIPP to assess the influence of (99m)Tc upscatter and (123)I downscatter, respectively. A rat-sized cylindrical phantom also contained both 100 or 300 MBq (99m)Tc-TF and 100 MBq (123)I-BMIPP. The two 10-ml syringes and phantom were scanned using a pinhole collimator for rats. Myocardial infarction model rats were examined using 300 MBq (99m)Tc-TF and 100 MBq (123)I-BMIPP. Two 1-ml syringes contained 105 MBq (99m)Tc-labeled hexamethylpropyleneamine oxime ((99m)Tc-HMPAO) and 35 MBq (123)I-labeled N-ω-fluoropropyl-2β-carbomethoxy-3β-(4-iodophenyl) nortropane ((123)I-FP-CIT). The two 1-ml syringes were scanned using a pinhole collimator for mice. Normal mice were examined using 105 MBq (99m)Tc-HMPAO and 35 MBq (123)I-FP-CIT. The relationship between SPECT radioactive counts and radioactivity was excellent. Downscatter contamination of (123)I-BMIPP exhibited fewer radioactive counts for 300 MBq (99m)Tc-TF without scatter correction (SC) in 125-150 keV. There was no upscatter contamination of (99m)Tc-TF in 150-175 keV. In the rat-sized phantom, the radioactive count ratio decreased to 4.0 % for 300 MBq (99m)Tc-TF without SC in 125-150 keV. In the rats, myocardial images and radioactive counts of (99m)Tc-TF with the dual tracer were identical to those of the (99m)Tc-TF single injection. Downscatter contamination of (123)I-FP-CIT was 4.2 % without SC in 125-150 keV. In the first injection of (99m)Tc-HMPAO and second injection of (123)I-FP-CIT, brain images and radioactive counts

  17. Diagnostic value of (99m)Tc-3PRGD2 scintimammography for differentiation of malignant from benign breast lesions: Comparison of visual and semi-quantitative analysis.

    PubMed

    Chen, Qianqian; Xie, Qian; Zhao, Min; Chen, Bin; Gao, Shi; Zhang, Haishan; Xing, Hua; Ma, Qingjie

    2015-01-01

    To compare the diagnostic value of visual and semi-quantitative analysis of technetium-99m-poly-ethylene glycol, 4-arginine-glycine-aspartic acid ((99m)Tc-3PRGD2) scintimammography (SMG) for better differentiation of benign from malignant breast masses, and also investigate the incremental role of semi-quantitative index of SMG. A total of 72 patients with breast lesions were included in the study. Technetium-99m-3PRGD2 SMG was performed with single photon emission computed tomography (SPET) at 60 min after intravenous injection of 749 ± 86MBq of the radiotracer. Images were evaluated by visual interpretation and semi-quantitative indices of tumor to non-tumor (T/N) ratios, which were compared with pathology results. Receiver operating characteristics (ROC) curve analyses were performed to determine the optimal visual grade, to calculate cut-off values of semi-quantitative indices, and to compare visual and semi-quantitative diagnostic values. Among the 72 patients, 89 lesions were confirmed by histopathology after fine needle aspiration biopsy or surgery, 48 malignant and 41 benign lesions. The mean T/N ratio of (99m)Tc-3PRGD2 SMG in malignant lesions was significantly higher than that in benign lesions (P<0.05). When grade 2 of the disease was used as cut-off value for the detection of primary breast cancer, the sensitivity, specificity and accuracy were 81.3%, 70.7%, and 76.4%, respectively. When a T/N ratio of 2.01 was used as cut-off value, the sensitivity, specificity and accuracy were 79.2%, 75.6%, and 77.5%, respectively. According to ROC analysis, the area under the curve for semi-quantitative analysis was higher than that for visual analysis, but the statistical difference was not significant (P=0.372). Compared with visual analysis or semi-quantitative analysis alone, the sensitivity, specificity and accuracy of visual analysis combined with semi-quantitative analysis in diagnosing primary breast cancer were higher, being: 87.5%, 82.9%, and 85

  18. Biodistribution of free and encapsulated 99mTc-fluconazole in an infection model induced by Candida albicans.

    PubMed

    de Assis, Danielle Nogueira; Araújo, Raquel Silva; Fuscaldi, Leonardo Lima; Fernandes, Simone Odília Antunes; Mosqueira, Vanessa Carla Furtado; Cardoso, Valbert Nascimento

    2018-03-01

    Candida spp is an etiologic agent of fungal infections in hospitals and resistance to treatment with antifungals has been extensively reported. Thus, it is very important to develop formulations that increase effectiveness with low toxicity. In this sense, nanocarriers have been investigated, once they modify drug biodistribution profile. Thus, this study aimed to evaluate the biodistribution of free and encapsulated 99m Tc-fluconazole into nanocapsules (NCs) in an experimental immunosuppressed murine model of Candida albicans infection. Fluconazole was radiolabeled with technetium-99 metastable ( 99m Tc) and encapsulated into conventional ( 99m Tc-Fluconazole-PLA-POLOX) and surface-modified ( 99m Tc-Fluconazole-PLA-PEG) NCs by the interfacial deposition of the preformed biodegradable polymer [poly (D,L-lactic acid) (PLA) and PLA-PEG (polyethyleneglycol)] followed by solvent evaporation. The size distribution and zeta potential of the NCs preparations were determined in a Zetasizer by photon correlation spectroscopy and laser Doppler anemometry, respectively. Free and encapsulated 99m Tc-fluconazole were administered intravenously in immunosuppressed mice bearing a local infection induced by Candida Albicans inoculation in the right thigh muscle. At pre-established time intervals, tissues and organs of interest were removed and radioactivity was measured in an automatic gamma radiation counter. The NCs diameter was between 200 and 400 nm with negative zeta potential values. Free 99m Tc-fluconazole was more rapidly eliminated by the renal system compared to the encapsulated drug in NCs, which remained longer in blood circulation. The uptake of conventional NCs by mononuclear phagocyte system organs was higher than the one demonstrated by the surface-modified NCs. Both NCs remained longer in the infectious focus when compared to free 99m Tc-fluconazole, but the results did not show a significant difference between NC formulations. These data indicate that these NCs

  19. Single photon source with individualized single photon certifications

    NASA Astrophysics Data System (ADS)

    Migdall, Alan L.; Branning, David A.; Castelletto, Stefania; Ware, M.

    2002-12-01

    As currently implemented, single-photon sources cannot be made to produce single photons with high probability, while simultaneously suppressing the probability of yielding two or more photons. Because of this, single photon sources cannot really produce single photons on demand. We describe a multiplexed system that allows the probabilities of producing one and more photons to be adjusted independently, enabling a much better approximation of a source of single photons on demand. The scheme uses a heralded photon source based on parametric downconversion, but by effectively breaking the trigger detector area into multiple regions, we are able to extract more information about a heralded photon than is possible with a conventional arrangement. This scheme allows photons to be produced along with a quantitative 'certification' that they are single photons. Some of the single-photon certifications can be significantly better than what is possible with conventional downconversion sources, as well as being better than faint laser sources. With such a source of more tightly certified single photons, it should be possible to improve the maximum secure bit rate possible over a quantum cryptographic link. We present an analysis of the relative merits of this method over the conventional arrangement.

  20. Quantitative estimation of infarct size by simultaneous dual radionuclide single photon emission computed tomography: comparison with peak serum creatine kinase activity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kawaguchi, K.; Sone, T.; Tsuboi, H.

    1991-05-01

    To test the hypothesis that simultaneous dual energy single photon emission computed tomography (SPECT) with technetium-99m (99mTc) pyrophosphate and thallium-201 (201TI) can provide an accurate estimate of the size of myocardial infarction and to assess the correlation between infarct size and peak serum creatine kinase activity, 165 patients with acute myocardial infarction underwent SPECT 3.2 +/- 1.3 (SD) days after the onset of acute myocardial infarction. In the present study, the difference in the intensity of 99mTc-pyrophosphate accumulation was assumed to be attributable to difference in the volume of infarcted myocardium, and the infarct volume was corrected by the ratiomore » of the myocardial activity to the osseous activity to quantify the intensity of 99mTc-pyrophosphate accumulation. The correlation of measured infarct volume with peak serum creatine kinase activity was significant (r = 0.60, p less than 0.01). There was also a significant linear correlation between the corrected infarct volume and peak serum creatine kinase activity (r = 0.71, p less than 0.01). Subgroup analysis showed a high correlation between corrected volume and peak creatine kinase activity in patients with anterior infarctions (r = 0.75, p less than 0.01) but a poor correlation in patients with inferior or posterior infarctions (r = 0.50, p less than 0.01). In both the early reperfusion and the no reperfusion groups, a good correlation was found between corrected infarct volume and peak serum creatine kinase activity (r = 0.76 and r = 0.76, respectively; p less than 0.01).« less

  1. 99mTc-HMPAO SPECT of the brain in mild to moderate traumatic brain injury patients: compared with CT--a prospective study.

    PubMed

    Nedd, K; Sfakianakis, G; Ganz, W; Uricchio, B; Vernberg, D; Villanueva, P; Jabir, A M; Bartlett, J; Keena, J

    1993-01-01

    Single photon emission computed tomography (SPECT) with Technetium-99m hexamethyl propylenamine oxime (Tc-99m-HMPAO) was used in 20 patients with mild to moderate traumatic brain injury (TBI) to evaluate the effects of brain trauma on regional cerebral blood flow (rCBF). SPECT scan was compared with CT scan in 16 patients. SPECT showed intraparenchymal differences in rCBF more often than lesions diagnosed with CT scans (87.5% vs. 37.5%). In five of six patients with lesions in both modalities, the area of involvement was relatively larger on SPECT scans than on CT scans. Contrecoup changes were seen in five patients on SPECT alone, two patients with CT alone and one patient had contrecoup lesions on CT and SPECT. Of the eight patients (50%) with skull fractures, seven (43.7%) had rCBF findings on SPECT scan and five (31.3%) demonstrated decrease in rCBF in brain underlying the fracture. All these patients with fractures had normal brain on CT scans. Conversely, extra-axial lesions and fractures evident on CT did not visualize on SPECT, but SPECT demonstrated associated changes in rCBF. Although there is still lack of clinical and pathological correlation, SPECT appears to be a promising method for a more sensitive evaluation of axial lesions in patients with mild to moderate TBI.

  2. Radiosynthesis and Biodistribution of 99mTc-Metronidazole as an Escherichia coli Infection Imaging Radiopharmaceutical.

    PubMed

    Iqbal, Anam; Naqvi, Syed Ali Raza; Rasheed, Rashid; Mansha, Asim; Ahmad, Matloob; Zahoor, Ameer Fawad

    2018-05-01

    Bacterial infection poses life-threatening challenge to humanity and stimulates to the researchers for developing better diagnostic and therapeutic agents complying with existing theranostic techniques. Nuclear medicine technique helps to visualize hard-to-diagnose deep-seated bacterial infections using radionuclide-labeled tracer agents. Metronidazole is an antiprotozoal antibiotic that serves as a preeminent anaerobic chemotherapeutic agent. The aim of this study was to develop technetium-99m-labeled metronidazole radiotracer for the detection of deep-seated bacterial infections. Radiosynthesis of 99m Tc-metronidazole was carried by reacting reduced technetium-99m and metronidazole at neutral pH for 30 min. The stannous chloride dihydrate was used as the reducing agent. At optimum radiolabeling conditions, ~ 94% radiochemical was obtained. Quality control analysis was carried out with a chromatographic paper and instant thin-layer chromatographic analysis. The biodistribution study of radiochemical was performed using Escherichia coli bacterial infection-induced rat model. The scintigraphic study was performed using E. coli bacterial infection-induced rabbit model. The results showed promising accumulation at the site of infection and its rapid clearance from the body. The tracer showed target-to-non-target ratio 5.57 ± 0.04 at 1 h post-injection. The results showed that 99m Tc-MNZ has promising potential to accumulate at E. coli bacterial infection that can be used for E. coli infection imaging.

  3. Hürthle cell tumor dwelling in hot thyroid nodules: preoperative detection with technetium-99m-MIBI dual-phase scintigraphy.

    PubMed

    Vattimo, A; Bertelli, P; Cintorino, M; Burroni, L; Volterrani, D; Vella, A; Lazzi, S

    1998-05-01

    Single injection dual-phase scintigraphy (early and late acquisitions) with 99mTc-MIBI was used to differentiate benign and malignant hot thyroid nodules. Thirteen euthyroid and two hyperthyroid patients displaying a hot thyroid nodule on the 99mTc scan due to an autonomously functioning thyroid nodule (AFTN) underwent early (15-30 min) and late (3-4 hr) thyroid scintigraphy after the administration of 740-1000 MBq 99mTc-MIBI. Visual scoring was done to assess nodular tracer uptake and retention. In addition, the nodular-to-thyroid (N/T) uptake ratio in the early and late image and the washout rates (WO) from the nodule and thyroidal tissue were measured. All patients underwent thyroid surgery. Histopathology revealed a Hürthle cell tumor in three nodules, a benign adenoma with oxyphilic metaplasia in two nodules and a benign adenoma without oxyphilic cells in the remaining 10 nodules. The Hürthle cell tumor nodules displayed intense and persistent uptake of 99mTc-MIBI (N/T was 2.81 +/- 0.52 and 5.53 +/- 1.06 in early and late images, respectively; WO from the nodule was 12.33 +/- 0.47, WO from the thyroidal tissue was 22.00 +/- 3.56). The benign nodules showed intense uptake in the early image and intense uptake to absent retention in the late image (N/T was 2.94 +/- 1.31 and 1.62 +/- 0.50 in the early and late images, respectively; WO from the nodule was 20.25 +/- 2.92, WO from the thyroidal tissue was 20.33 +/- 2.92). Single injection dual-phase 99mTc-MIBI scintigraphy of the thyroid with AFTN can identify nodules as a result of the activity of a Hürthle cell tumor, since these tumors cause intense and persistent tracer uptake in contrast with a benign AFTN.

  4. Solar neutrino production of technetium-97 and technetium-98.

    PubMed

    Cowan, G A; Haxton, W C

    1982-04-02

    It may be possible to determine the boron-8 solar neutrino flux, averaged over the past several million years, from the concentration of technetium-98 in molybdenite. The mass spectrometry of this system is greatly simplified by the absence of stable technetium isotopes, and the presence of the fission product technetium-99 provides a monitor of uiranium-induced backgrounds. This geochemical experiment could provide the first test of nonstandard solar models that suggest a relation between the chlorine-37 solar neutrino puzzle and the recent ice age.

  5. Development and study of 99mTc-1-Thio-D-glucose for visualization of malignant tumors

    NASA Astrophysics Data System (ADS)

    Zeltchan, R.; Medvedeva, A.; Sinilkin, I.; Bragina, O.; Chernov, V.; Stasyuk, E.; Rogov, A.; Il'ina, E.; Skuridin, V.

    2017-09-01

    The preclinical studies of 99mTc-1-Thio-D-glucose, a new tumor-seeking agent based on technetium-99m-labeled glucose derivative, were conducted, and the feasibility of using this radiopharmaceutical for tumor visualization was studied. The preclinical studies were carried out strictly in accordance with the local legislation and were regulated by the generally accepted research standards. 99mTc-1-Thio-D-glucose was found to have optimal pharmacokinetic and physico-chemical properties for diagnostic imaging and was proved to belong to the low-toxic substances. The potential utility of 99mTc-1-thio-D-glucose for tumor imaging was studied in vitro and in vivo models. The present study demonstrated that 99mTc-1-Thio-D-glucose is a prospective radiopharmaceutical for cancer visualization.

  6. Synthesis, Characterization, and Preclinical Evaluation of (99m)Tc-Labeled Macrobicyclic and Tricyclic Chelators as Single Photon Emission Computed Tomography Tracer.

    PubMed

    Yadav, Neelam; Chuttani, Krishna; Mishra, Anil K; Singh, Bachcha

    2016-05-01

    The novel tetraaza macrobicyclic chelator 3,6,9,15-tetraazabicyclo[9.3.1]pentadeca-1(15),11,13-triene-2,10-dione (TBPD) and pentaaza macrotricyclic chelator 9-oxa-3,6,12,15,21-pentaazatricyclo[15,3,2,1]trieicos-1(21),17,19-triene-2,7,11,16-tetradione (OPTT) were synthesized, characterized, and radiolabeled with (99m)Tc to produce (99m)Tc-TBPD and (99m)Tc-OPTT. These radiolabeled complexes were prepared with high radiolabeling yield, radiochemical purity, and good in vitro stability up to 24 h. The labeling efficiency of (99m)Tc-TBPD and (99m)Tc-OPTT was found 98% and 97%. In vitro serum stability of (99m)Tc-TBPD was found to be 95.2%, while that of (99m)Tc-OPTT 94.2% up to 24 h. Blood kinetics experiments of (99m)Tc-labeled complexes showed biphasic pattern of blood clearance. About 99.57 ± 0.89% activity of (99m)Tc-TBPD and 99.42 ± 0.88% activity of (9m)Tc-OPTT were cleared off blood stream at 24 h postadministration. The biological half-life of (99m) Tc-TBPD was observed: t1/2(F) 1 h 5 min and t1/2(S) 12 h and biological half-life of (99m)Tc-OPTT was observed: t1/2(F) 1 h 10 min and t1/2(S) 9 h 50 min, respectively. The biodistribution studies revealed that maximum uptake of (99m)Tc-TBPD was found in liver, concluded that excretory pathway is hepatobiliary, while that of (99m)Tc-OPTT was renal as well as hepatobiliary. The negligible activity observed in stomach confirming the stability of radiolabeled complex in biological milieu. In vitro cytotoxicity study of TBPD and OPTT did not show any considerable antiproliferative activity against cancer cells of human cervical SW756, HeLa, and glioblastoma U-87, U373 cell lines. © 2015 John Wiley & Sons A/S.

  7. Biliary excretion of technetium-99m-sestamibi in wild-type dogs and in dogs with intrinsic (ABCB1-1Delta mutation) and extrinsic (ketoconazole treated) P-glycoprotein deficiency.

    PubMed

    Coelho, J C; Tucker, R; Mattoon, J; Roberts, G; Waiting, D K; Mealey, K L

    2009-10-01

    P-glycoprotein (P-gp), the product of ABCB1 gene, is thought to play a role in the biliary excretion of a variety of drugs, but specific studies in dogs have not been performed. Because a number of endogenous (ABCB1 polymorphisms) and exogenous (pharmacological P-gp inhibition) factors can interfere with normal P-gp function, a better understanding of P-gp's role in biliary drug excretion is crucial in preventing adverse drug reactions and drug-drug interactions in dogs. The objectives of this study were to compare biliary excretion of technetium-99m-sestamibi ((99m)Tc-MIBI), a radio-labelled P-gp substrate, in wild-type dogs (ABCB1 wild/wild), and dogs with intrinsic and extrinsic deficiencies in P-gp function. Dogs with intrinsic P-gp deficiency included ABCB1 mut/mut dogs, and dogs with presumed intermediate P-gp phenotype (ABCB1 mut/wild). Dogs with extrinsic P-gp deficiency were considered to be ABCB1 wild/wild dogs treated with the P-gp inhibitor ketoconazole (5 mg/kg PO q12h x 9 doses). Results from this study indicate that ABCB1 mut/mut dogs have significantly decreased biliary excretion of (99m)Tc-MIBI compared with ABCB1 wild/wild dogs. Treatment with ketoconazole significantly decreased biliary excretion of (99m)Tc-MIBI in ABCB1 wild/wild dogs. P-gp appears to play an important role in the biliary excretion of (99m)Tc-MIBI in dogs. It is likely that concurrent administration of a P-gp inhibitor such as ketoconazole will decrease P-gp-mediated biliary excretion of other substrate drugs as well.

  8. New method for the selective labeling of erythrocytes in whole blood with Tc-99m

    DOEpatents

    Srivastava, S.C.; Babich, J.W.; Straub, R.; Richards, P.

    1984-01-27

    Method and kit are described for the preparation of /sup 99m/Tc labeled red blood cells using whole blood in a closed sterile system containing stannous tin in a form such that it will enter the red blood cells and be available therein for the reduction of technetium.

  9. [Gastrointestinal bleeding from capillary hemangioma of the ileum detected by 99mTc-HSAD scintigraphy].

    PubMed

    Asano, Y; Ishii, K; Sagiuchi, T; Aoki, Y; Yanaihara, H; Hayakawa, K

    2001-05-01

    It has been well-known that technetium-99m-human serum albumin-diethylenetriaminepenta-acetic acid (99mTc-HSAD) scintigraphy is useful for diagnosis of the localization of the gastrointestinal arterial or venous bleeding. In this report, we describe a case of venous bleeding from capillary hemangioma of the ileum end detected by 99mTc-HSAD scintigraphy. This patient was a 9-year-old girl with severe anemia. Gastrointestinal bleeding was suspected from her clinical course and laboratory tests. Immediately after melena occurred, 99mTc-HSAD scintigraphy showed the extravasation of RI suggesting gastrointestinal bleeding in the ileum end. Abdominal angiography immediately after 99mTc-HSAD scintigraphy, however, could not show the extravasation of contrast agent. Because the condition of the patient became worse, laparotomy was performed on the basis of 99mTc-HSAD scintigraphy findings. At surgery, venous bleeding from capillary hemangioma in the ileum end was observed. It was suggested that 99mTc-HSAD scintigraphy was very useful for identifying the gastrointestinal venous bleeding.

  10. 99mTc-3P4-RGD2 Scintimammography in the Assessment of Breast Lesions: Comparative Study with 99mTc-MIBI

    PubMed Central

    Gao, Shi; Ji, Tiefeng; Wen, Qiang; Song, Yan; Zhu, Lei; Xu, Zheli; Liu, Lin

    2014-01-01

    Purpose To compare the potential application of 99mTc-3P-Arg-Gly-Asp (99mTc-3P4-RGD2) scintimammography (SMM) and 99mTc-methoxyisobutylisonitrile (99mTc-MIBI) SMM for the differentiation of malignant from benign breast lesions. Method Thirty-six patients with breast masses on physical examination and/or suspicious mammography results that required fine needle aspiration cytology biopsy (FNAB) were included in the study. 99mTc-3P4-RGD2 and 99mTc-MIBI SMM were performed with single photon emission computed tomography (SPECT) at 60 min and 20 min respectively after intravenous injection of 738±86 MBq radiotracers on a separate day. Images were evaluated by the tumor to non-tumor localization ratios (T/NT). Receiver operating characteristic (ROC) curve analysis was performed on each radiotracer to calculate the cut-off values of quantitative indices and to compare the diagnostic performance for the ability to differentiate malignant from benign diseases. Results The mean T/NT ratio of 99mTc-3P4-RGD2 in malignant lesions was significantly higher than that in benign lesions (3.54±1.51 vs. 1.83±0.98, p<0.001). The sensitivity, specificity, and accuracy of 99mTc-3P4-RGD2 SMM were 89.3%, 90.9% and 89.7%, respectively, with a T/NT cut-off value of 2.40. The mean T/NT ratio of 99mTc-MIBI in malignant lesions was also significantly higher than that in benign lesions (2.86±0.99 vs. 1.51±0.61, p<0.001). The sensitivity, specificity and accuracy of 99mTc-MIBI SMM were 87.5%, 72.7% and 82.1%, respectively, with a T/NT cut-off value of 1.45. According to the ROC analysis, the area under the curve for 99mTc-3P4-RGD2 SMM (area = 0.851) was higher than that for 99mTc-MIBI SMM (area = 0.781), but the statistical difference was not significant. Conclusion 99mTc-3P4-RGD2 SMM does not provide any significant advantage over the established 99mTc-MIBI SMM for the detection of primary breast cancer. The T/NT ratio of 99mTc-3P4-RGD2 SMM was significantly higher than that of 99m

  11. Evaluation of interobserver variability of parenchymal phase of Tc-99m mercaptoacetyltriglycine and Tc-99m dimercaptosuccinic acid renal scintigraphy

    PubMed Central

    Erdoğan, Zeynep; Abdülrezzak, Ümmühan; Silov, Güler; Özdal, Ayşegül; Turhal, Özgül

    2014-01-01

    Objective: The aim of this study was to investigate the variability in the interpretation of parenchymal abnormalities and to assess the differences in interpretation of routine renal scintigraphic findings on posterior view of technetium-99m dimercaptosuccinic acid (pvDMSA) scans and parenchymal phase of technetium-99m mercaptoacetyltriglycine (ppMAG3) scans by using standard criterions to make standardization and semiquantitative evaluation and to have more accurately correlation. Materials and Methods: Two experienced nuclear medicine physicians independently interpreted pvDMSA scans of 204 and ppMAG3 scans of 102 pediatric patients, retrospectively. Comparisons were made by visual inspection of pvDMSA scans, and ppMAG3 scans by using a grading system modified from Itoh et al. According to this, anatomical damage of the renal parenchyma was classified into six types: Grade 0-V. In the calculation of the agreement rates, Kendall correlation (tau-b) analysis was used. Results: According to our findings, excellent agreement was found for DMSA grade readings (DMSA-GR) (tau-b = 0.827) and good agreement for MAG3 grade readings (MAG3-GR) (tau-b = 0.790) between two observers. Most of clear parenchymal lesions detected on pvDMSA scans and ppMAG3 scans identified by observers equally. Studies with negative or minimal lesions reduced correlation degrees for both DMSA-GR and MAG3-GR. Conclusion: Our grading system can be used for standardization of the reports. We conclude that standardization of criteria and terminology in the interpretations may result in higher interobserver consistency, also improve low interobserver reproducibility and objectivity of renal scintigraphy reports. PMID:24761059

  12. Effect of Technetium-99 sources on its retention in low activity waste glass

    NASA Astrophysics Data System (ADS)

    Luksic, Steven A.; Kim, Dong-Sang; Um, Wooyong; Wang, Guohui; Schweiger, Michael J.; Soderquist, Chuck Z.; Lukens, Wayne; Kruger, Albert A.

    2018-05-01

    Small-scale crucible melting tests on simulated waste glass were performed with technetium-99 (Tc-99) introduced as different species in a representative low activity waste simulant. The glass saw an increase in Tc-99 retention when TcO2•2H2O and various Tc-minerals containing reduced tetravalent Tc were used compared to tests in which pertechnetate with heptavalent Tc was used. We postulate that the increase of Tc retention is likely caused by different reaction paths for Tc incorporation into glass during early stages of melting, rather than the low volatility of reduced tetravalent Tc compounds, which has been a generally accepted idea. Additional studies are needed to clarify the exact mechanisms relevant to the effect of reduced Tc compounds on Tc incorporation into or volatilization from the glass melt.

  13. Detection of urinary extravasation by delayed technetium-99m DTPA renal imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taki, J.; Tonami, N.; Aburano, T.

    Delayed imaging with Tc-99m DTPA renal scintigraphy demonstrated urinary extravasation in a patient with acute anuria in whom early sequential imaging showed no abnormal extrarenal radionuclide accumulation.

  14. Development of kit formulations for (99m) TcN-MPO: a cationic radiotracer for myocardial perfusion imaging.

    PubMed

    Zheng, Yumin; Ji, Shundong; Tomaselli, Elena; Liu, Shuang

    2014-07-01

    The objective of this study was to develop a kit formulation for [(99m) TcN(mpo)(PNP5)](+) (MPO = 2-mercaptopyridine oxide), ((99m) TcN-MPO) to support its clinical evaluations as a SPECT radiotracer. Radiolabeling studies were performed using three different formulations (two-vial formulation and single-vial formulations with/without SnCl2 ) to explore the factors influencing radiochemical purity (RCP) of (99m) TcN-MPO. We found that the most important factor affecting the RCP of (99m) TcN-MPO was the purity of PNP5. (99m) TcN-MPO was prepared >98% RCP (n = 20) using the two-vial formulation. For single-vial formulations with/without SnCl2 , β-cyclodextrin (β-CD) is particularly useful as a stabilizer for PNP5. The RCP of (99m) TcN-MPO was 95-98% using β-CD, but its RCP was only 90-93% with γ-cyclodextrin (γ-CD). It seems that PNP5 fits better into the inner cavity of β-CD, which forms more stable inclusion complex than γ-CD in the single-vial formulations. The results from biodistribution and imaging studies in Sprague-Dawley rats clearly demonstrated biological equivalence of three different formulations. Single photon-emission computed tomography data suggested that high quality images could be obtained at 0-30-min post-injection without significant interference from the liver radioactivity. Considering the ease for (99m) Tc-labeling and high RCP of (99m) TcN-MPO, the non-SnCl2 single-vial formulation is an attractive choice for future clinical studies. Copyright © 2014 John Wiley & Sons, Ltd.

  15. Technetium-99 conjugated with methylene diphosphonate inhibits receptor activator of nuclear factor-κB ligand-induced osteoclastogenesis.

    PubMed

    Gong, Wei; Dou, Huan; Liu, Xianqin; Sun, Lingyun; Hou, Yayi

    2012-10-01

    1. In the present study, we investigated the effects of technetium-99 conjugated with methylene diphosphonate ((99)Tc-MDP), an agent used in radionuclide therapy, on receptor activator of nuclear factor-κB ligand (RANKL)-induced osteoclastogenesis and explored the underlying mechanisms. 2. The murine macrophage cell line RAW264.7 and bone marrow-derived-macrophages from C57BL/6 mice (BMM) were used as models for osteoclastogenesis in vitro. The expression of some key factors in RANKL (50 ng/mL)-induced osteoclastogenesis in RAW264.7 cells was investigated by flow cytometry and real-time reverse transcription-polymerase chain reaction (RT-PCR). To detect multinucleated osteoclast formation, RAW264.7 cells were induced with RANKL for 4 days, whereas BMM were induced by 50 ng/mL RANKL and 20 ng/mL macrophage colony-stimulating factor for 7 days, before being stained with tartrate-resistant acid phosphatase. 3. Osteoclastogenesis was evaluated using the osteoclast markers CD51, matrix metalloproteinase (MMP)-9 and cathepsin K. At 0.01 μg/mL, (99)Tc-MDP significantly inhibited RANKL-induced osteoclastogenesis without any cytotoxicity. In addition, (99)Tc-MDP abolished the appearance of multinucleated osteoclasts. 4. Real-time RT-PCR analysis of transcription factor expression revealed that (99)Tc-MDP inhibited the expression of c-Fos and nuclear factor of activated T cells. In addition, (99)Tc-MDP inhibited the expression of the inflammatory factors interleukin (IL)-6, tumour necrosis factor-α and IL-1β. Finally, (99)Tc-MDP inhibited the activation of mitogen-activated protein kinases in RAW264.7 cells following RANKL stimulation. 5. In conclusion, (99)Tc-MDP possesses anti-osteoclastogenic activity against RANKL-induced osteoclast formation. © 2012 The Authors Clinical and Experimental Pharmacology and Physiology © 2012 Wiley Publishing Asia Pty Ltd.

  16. A comparison of rat SPECT images obtained using (99m)Tc derived from 99Mo produced by an electron accelerator with that from a reactor.

    PubMed

    Galea, R; Wells, R G; Ross, C K; Lockwood, J; Moore, K; Harvey, J T; Isensee, G H

    2013-05-07

    Recent shortages of molybdenum-99 ((99)Mo) have led to an examination of alternate production methods that could contribute to a more robust supply. An electron accelerator and the photoneutron reaction were used to produce (99)Mo from which technetium-99m ((99m)Tc) is extracted. SPECT images of rat anatomy obtained using the accelerator-produced (99m)Tc with those obtained using (99m)Tc from a commercial generator were compared. Disks of (100)Mo were irradiated with x-rays produced by a 35 MeV electron beam to generate about 1110 MBq (30 mCi) of (99)Mo per disk. After target dissolution, a NorthStar ARSII unit was used to separate the (99m)Tc, which was subsequently used to tag pharmaceuticals suitable for cardiac and bone imaging. SPECT images were acquired for three rats and compared to images for the same three rats obtained using (99m)Tc from a standard reactor (99)Mo generator. The efficiency of (99)Mo-(99m)Tc separation was typically greater than 90%. This study demonstrated the delivery of (99m)Tc from the end of beam to the end user of approximately 30 h. Images obtained using the heart and bone scanning agents using reactor and linac-produced (99m)Tc were comparable. High-power electron accelerators are an attractive option for producing (99)Mo on a national scale.

  17. Technetium-99m labeled red blood cells in the evaluation of hemangiosarcoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joseph, U.A.; Jhingran, S.G.

    Imaging with Tc-99m labeled red blood cells (RBC) is increasingly being used in the detection of acute gastro-intestinal bleeding, especially in patients with intermittent bleeding. A patient is presented in whom the labeled RBC scan was helpful in the incidental discovery of a previously unsuspected probable angiosarcoma of the right femur and adjacent soft tissues of the right hip due to the blood pool or blush effect of the labeled cells. The labeled RBC scan also identified extravasation due to active gastrointestinal bleeding from a previously unknown angiosarcoma of the ascending colon. Thus, the Tc-99m labeled RBC scan was usefulmore » in simultaneously detecting extravasation and blood pool effect at two remote tumor sites in the same patient.« less

  18. [Regional blood flow and bone uptake of methylene-diphosphonate-technetium-99m].

    PubMed

    Vattimo, A; Martini, G; Pisani, M

    1983-05-30

    Sudeck's atrophy of the foot is an acute, patchy osteoporosis that, on bone scan, shows an increase in both bone blood flow and local bone uptake of bone-seeking radionuclides. The purpose of this study was to evaluate the relationship between bone uptake of 99mTc-MDP and local bone blood flow. In some patients with Sudeck's atrophy of one foot we measured local bone blood flow and bone uptake of 99mTc-MDP. External counting of radioactivity, with a count-rate of 1 second was performed for 60 minutes after i.v. injection of a known dose of 99mTc-MDP in some patients with Sudeck's atrophy of the foot. The regions of interest (ROI) were selected on the basis of a bone scan performed 24 hours earlier. We assumed that the data recorded during the first seconds (7-10) reflect local blood flow and the data at 60 minutes reflect the bone uptake. The ratio between the local blood flow in the involved and healthy foot was higher than the local bone uptake ratio. The ratio between bone uptake and local bone blood flow was higher in the normal foot than in the affected one. These results suggest that the bone avidity for bone-seeking radionuclides is lower in Sudeck's atrophy than in normal bone.

  19. Increased technetium-99 m hydroxy diphosphonate soft tissue uptake on bone scintigraphy in chronic kidney disease patients with secondary hyperparathyroidism: correlation with hyperphosphataemia.

    PubMed

    Enevoldsen, Lotte Hahn; Heaf, James; Højgaard, Liselotte; Zerahn, Bo; Hasbak, Philip

    2017-03-01

    In bone scan patients with dialysis-treated chronic kidney disease (CKD) and hyperparathyroidism, soft tissue accumulation of technetium-99 m hydroxy/methylene diphosphonate (Tc-99 m-HDP/MDP) has been reported primarily in case reports and usually explained by hypercalcaemia and/or hyperphosphataemia. As human vascular smooth muscle cells produce hydroxyapatite during cell culture with increased phosphate levels and as Tc-99 m-HDP/MDP primarily binds to hydroxyapatite, we hypothesized that soft tissue accumulation would be found in patients with hyperphosphataemia. We identified 63 CKD patients diagnosed with secondary hyperparathyroidism admitted for Tc-99 m-HDP bone scan. Baseline characteristics and mean concentrations of biochemical markers (including P-calcium and P-phosphate) taken 0-3 months prior to the bone scans were collected. Soft tissue uptake was detected on bone scans in 37 of 63 (59%) patients. Primary locations were in the heart (27/37 = 73%), muscles (12/37 = 32%), lung (9/37 = 24%) and gastrointestinal tract (6/37 = 16%), and 13 of 37 (35%) patients had simultaneous uptake in more than one location. Regarding biochemical markers, patients with soft tissue uptake only differed from patients without in terms of plasma phosphate levels (1·95 ± 0·15 (n = 37) versus 1·27 ± 0·08 (n = 26), P = 0·0012). All patients with myocardial uptake (n = 27) had a coronary arteriography-verified history of coronary artery disease (CAD), whereas CAD was only present in six of the 36 patients without myocardial uptake. In conclusion, dialysis-treated CKD patients with secondary hyperparathyroidism have a high incidence of soft tissue uptake, and this finding is strongly correlated with elevated phosphate, but not calcium values. © 2015 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  20. Direct comparison of solid-phase gastric emptying times assessed by means of a carbon isotope-labeled sodium acetate breath test and technetium Tc 99m albumin colloid radioscintigraphy in healthy cats.

    PubMed

    Schmitz, Silke; Götte, Birte; Borsch, Christian; Kunz, Clemens; Failing, Klaus; Neiger, Reto

    2014-07-01

    To directly compare solid-phase gastric emptying times assessed by means of a [(13)C]sodium acetate breath test ([(13)C]-SABT) and technetium Tc 99m albumin colloid radioscintigraphy ((99m)Tc-ACR) in healthy cats. 12 healthy cats. After ingestion of a test meal containing 50 mg of [(13)C]sodium acetate and 250 MBq of (99m)Tc-albumin colloid, each cat underwent simultaneous [(13)C]-SABT and (99m)Tc-ACR on 2 consecutive days. Breath samples and scintigrams were acquired at 30, 60, 90, 120, 150, 180, 210, 240, 300, 360, 480, and 600 minutes after meal ingestion. Quartiles of gastric emptying (25%, 50%, and 75%) were calculated for breath test analysis by use of the area under the curve of the (13)C:(12)C ratio. Quartiles of gastric emptying times were extrapolated from the scintigraphic findings by beans of nonlinear curve regression analysis. Mean ± SD gastric half-emptying (50%) times obtained with [(13)C]-SABT and (99m)Tc-ACR, were 239 ± 28 minutes and 276 ± 59 minutes, respectively. A 2-way repeated-measures ANOVA revealed that mean gastric emptying times determined with [(13)C]-SABT and (99m)Tc-ACR differed significantly. For the stages of gastric emptying, Pearson correlation between the 2 methods was good at 25% (r = 0.655) and weak at 50% (r = 0.588) and 75% (r = 0.566)of gastric emptying. Results indicated that the [(13)C]-SABT can be a valid alternative to (99m)Tc-ACR in healthy cats; it was easy to perform, was tolerated well by the cats, and had acceptable correlation to scintigraphic findings at gastric emptying of 25%, 50% and 75%. Studies in cats with delayed gastric emptying will be needed to verify the validity of the [(13)C]-SABT.

  1. The absorption of (99m)Tc-alendronate given by rectal route in rabbits.

    PubMed

    Asikoğlu, Makbule; Ozguney, Isik; Ozcan, Ipek; Orumlu, Oya; Guneri, Tamer; Koseoğlu, Kamil; Ozkilic, Hayal

    2008-01-01

    Alendronate sodium (ALD) is a bisphosphonate medication used in the treatment and prevention of osteoporosis. Absorption of ALD as oral formulation is very poor (0.5%-1%). Its bioavailability can decrease with food effect. It has some gastrointestinal adverse effects such as gastritis, gastric ulcer, and esophagitis. The aim of this study was to develop a rectal formulation of ALD as an alternative to oral route and to investigate the absorption of it by using gamma scintigraphy. For this reason, ALD was labeled with Technetium-99m ((99m)Tc) by direct method. The radiochemical characterization of the (99m)Tc-ALD was carried out by paper chromatography, thin layer chromatography, and electrophoresis methods. The labeling efficiency of (99m)Tc-ALD was found 99% without significant changes until 6 h postlabeling at room temperature. The rectal suppositories containing (99m)Tc-ALD were prepared by fusion method using polyethylene glycol (PEG) 1500. The (99m)Tc-labeled ALD suppositories were administrated to rabbits by rectal route. Serial scintigrams over all bodies of the rabbits were obtained at different time intervals using a gamma camera. We found that the rectal absorption of (99m)Tc-ALD from suppository formulation was possible. According to our results, this formulation of ALD can be suggested for the therapy of osteoporosis as an alternative route.

  2. Effect of Technetium-99 sources on its retention in low activity waste glass

    DOE PAGES

    Luksic, Steven A.; Kim, Dong Sang; Um, Wooyong; ...

    2018-03-02

    Small-scale crucible melting tests on simulated waste glass were performed with technetium-99 (Tc-99) introduced as different species in a representative low activity waste simulant. The glass saw an increase in Tc-99 retention when TcO 2∙2H 2O and various Tc-minerals containing reduced tetravalent Tc were used compared to tests in which pertechnetate with heptavalent Tc was used. Here, we postulate that the increase of Tc retention is likely caused by different reaction paths for Tc incorporation into glass during early stages of melting, rather than the low volatility of reduced tetravalent Tc compounds, which has been a generally accepted idea. Finally,more » additional studies are needed to clarify the exact mechanisms relevant to the effect of reduced Tc compounds on Tc incorporation into or volatilization from the glass melt.« less

  3. Effect of Technetium-99 sources on its retention in low activity waste glass

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luksic, Steven A.; Kim, Dong-Sang; Um, Wooyong

    Small-scale crucible melting tests on simulated waste glass were performed with technetium-99 (Tc-99) introduced as different species in a representative low activity waste simulant. The glass saw an increase in Tc-99 retention when TcO2∙2H2O and various Tc-minerals containing reduced tetravalent Tc were used compared to tests in which pertechnetate with hexavalent Tc was used. We postulate that the increase of Tc retention is likely caused by different reaction paths for Tc incorporation into glass during early stages of melting, rather than the low volatility of reduced tetravalent Tc compounds, which has been a generally accepted idea. Additional studies are neededmore » to clarify the exact mechanisms relevant to the effect of reduced Tc compounds on Tc incorporation into or volatilization from glass melt.« less

  4. Effect of Technetium-99 sources on its retention in low activity waste glass

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luksic, Steven A.; Kim, Dong Sang; Um, Wooyong

    Small-scale crucible melting tests on simulated waste glass were performed with technetium-99 (Tc-99) introduced as different species in a representative low activity waste simulant. The glass saw an increase in Tc-99 retention when TcO 2∙2H 2O and various Tc-minerals containing reduced tetravalent Tc were used compared to tests in which pertechnetate with heptavalent Tc was used. Here, we postulate that the increase of Tc retention is likely caused by different reaction paths for Tc incorporation into glass during early stages of melting, rather than the low volatility of reduced tetravalent Tc compounds, which has been a generally accepted idea. Finally,more » additional studies are needed to clarify the exact mechanisms relevant to the effect of reduced Tc compounds on Tc incorporation into or volatilization from the glass melt.« less

  5. Effect of Technetium-99 sources on its retention in low activity waste glass

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luksic, Steven A.; Kim, Dong-Sang; Um, Wooyong

    © 2018 Small-scale crucible melting tests on simulated waste glass were performed with technetium-99 (Tc-99) introduced as different species in a representative low activity waste simulant. The glass saw an increase in Tc-99 retention when TcO 2 ∙2H 2 O and various Tc-minerals containing reduced tetravalent Tc were used compared to tests in which pertechnetate with heptavalent Tc was used. We postulate that the increase of Tc retention is likely caused by different reaction paths for Tc incorporation into glass during early stages of melting, rather than the low volatility of reduced tetravalent Tc compounds, which has been a generallymore » accepted idea. Additional studies are needed to clarify the exact mechanisms relevant to the effect of reduced Tc compounds on Tc incorporation into or volatilization from the glass melt.« less

  6. Effect of Technetium-99 sources on its retention in low activity waste glass

    DOE PAGES

    Luksic, Steven A.; Kim, Dong-Sang; Um, Wooyong; ...

    2018-05-01

    © 2018 Small-scale crucible melting tests on simulated waste glass were performed with technetium-99 (Tc-99) introduced as different species in a representative low activity waste simulant. The glass saw an increase in Tc-99 retention when TcO 2 ∙2H 2 O and various Tc-minerals containing reduced tetravalent Tc were used compared to tests in which pertechnetate with heptavalent Tc was used. We postulate that the increase of Tc retention is likely caused by different reaction paths for Tc incorporation into glass during early stages of melting, rather than the low volatility of reduced tetravalent Tc compounds, which has been a generallymore » accepted idea. Additional studies are needed to clarify the exact mechanisms relevant to the effect of reduced Tc compounds on Tc incorporation into or volatilization from the glass melt.« less

  7. Recruitment of 99m-technetium- or 111-indium-labelled polymorphonuclear leucocytes in experimentally induced pyogranulomas in lambs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guilloteau, L.; Pepin, M.; Pardon, P.

    1990-10-01

    The recruitment of polymorphonuclear leucocytes (PMNs) during the development of experimental pyogranulomas induced by Corynebacterium pseudotuberculosis was followed in nine male lambs by scintigraphic examination. Autologous blood PMNs were labelled with 99m-technetium or 111-indium and were re-injected intravenously into infected lambs. The functional properties of the labelled cells were monitored (1) in vitro by measuring their phagocytic and bactericidal activity against C. pseudotuberculosis and their chemotaxis under agarose, and (2) in vivo by following scintigraphically their capacity to accumulate in an inflammatory focus induced by intradermal injection of latex beads coated with Salmonella abortus equi lipopolysaccharide. Following inoculation of corynebacteriamore » into the right ear of lambs, radioactive foci were observed to be localized in the right ear and in the draining lymph nodes during the 4 days following inoculation. Histopathological examination performed 32 h after inoculation confirmed the intense accumulation of PMNs at these sites. With the exception of one animal, which presented visible foci in the neck 14 days postinoculation, no radioactive foci were observed during the later phases of experimental infection, despite the presence of multiple pyogranulomas which were confirmed by bacteriological examination after necropsy of the lambs. Histopathological examination of these lesions revealed layers of fibroblasts, lymphocytes, and macrophages surrounding a necrotic centre. The results of these studies suggest that the contribution of PMNs during the chronic phase of inflammation is considerably reduced in comparison with the acute inflammatory phase of the infectious process.« less

  8. Evaluating 99mTc Auger electrons for targeted tumor radiotherapy by computational methods.

    PubMed

    Tavares, Adriana Alexandre S; Tavares, João Manuel R S

    2010-07-01

    Technetium-99m (99mTc) has been widely used as an imaging agent but only recently has been considered for therapeutic applications. This study aims to analyze the potential use of 99mTc Auger electrons for targeted tumor radiotherapy by evaluating the DNA damage and its probability of correct repair and by studying the cellular kinetics, following 99mTc Auger electron irradiation in comparison to iodine-131 (131I) beta minus particles and astatine-211 (211At) alpha particle irradiation. Computational models were used to estimate the yield of DNA damage (fast Monte Carlo damage algorithm), the probability of correct repair (Monte Carlo excision repair algorithm), and cell kinetic effects (virtual cell radiobiology algorithm) after irradiation with the selected particles. The results obtained with the algorithms used suggested that 99mTc CKMMX (all M-shell Coster-Kroning--CK--and super-CK transitions) electrons and Auger MXY (all M-shell Auger transitions) have a therapeutic potential comparable to high linear energy transfer 211At alpha particles and higher than 131I beta minus particles. All the other 99mTc electrons had a therapeutic potential similar to 131I beta minus particles. 99mTc CKMMX electrons and Auger MXY presented a higher probability to induce apoptosis than 131I beta minus particles and a probability similar to 211At alpha particles. Based on the results here, 99mTc CKMMX electrons and Auger MXY are useful electrons for targeted tumor radiotherapy.

  9. Streptozotocin (STZ) and schistosomiasis mansoni change the biodistribution of radiopharmaceutical sodium (99m)Tc-pertechnetate in mice.

    PubMed

    Góes, Vanessa Coelho; Neves, Renata Heisler; Arnóbio, Adriano; Bernardo-Filho, Mario; Machado-Silva, José Roberto

    2016-09-01

    Technetium-99m ((99m)Tc) is a radionuclide commonly used in nuclear medicine to obtain (99m)Tc-radiopharmaceuticals, which can be used to evaluate either physiological processes or changes related to diseases. It is also used in some experimental studies. Streptozotocin (STZ) administration to rodents causes lesions in very early stages and induces severe and permanent diabetes. Most morbidity of schistosomiasis mansoni is attributed to a granulomatous inflammatory response and associated liver fibrosis. This study was designed to investigate whether STZ administration and schistosomiasis modify the biodistribution of the radiopharmaceutical sodium (99m)Tc-pertechnetate. Adult female mice were infected by exposure to 100Schistosoma mansoni cercariae (BH strain, Belo Horizonte, Brazil) and euthanized after nine weeks. STZ was administered by a single intraperitoneal injection of 100mg/kg body weight, 3 or 15days before euthanasia. Each animal received 100μl of sodium (Na) (99m)Tc-pertechnetate ((99m)TcO4(-)) (740kBq). The animals were divided into four groups: A, uninfected; B, infected; C, uninfected + STZ; and D, infected + STZ. Blood, brain, thyroid, heart, lungs, liver, spleen, pancreas and kidneys were removed. The radioactivity was counted and the percentage of the injected dose of Na(99m)TcO4 per gram of the organ (% ID/g) was determined. Three days after the STZ injection, there was a decrease of Na(99m)TcO4 uptake by the liver, lungs, pancreas and kidneys (p<0.05) in group D when compared with group A. After 15days, the decrease of Na(99m)TcO4 uptake occurred also in the brain, thyroid, heart, spleen and blood (p<0.05) in group D. We demonstrated modifications on the biodistribution of Na(99m)TcO4 due to STZ administration and schistosomiasis, possibly due to physiological alterations in some organs. The biodistribution of radiopharmaceutical Na(99m)TcO4 should be carefully evaluated in subjects with diabetes and/or schistosomiasis infection. Copyright

  10. Experimental study of radiopharmaceuticals based on technetium-99m labeled derivative of glucose for tumor diagnosis

    NASA Astrophysics Data System (ADS)

    Zeltchan, R.; Medvedeva, A.; Sinilkin, I.; Bragina, O.; Chernov, V.; Stasyuk, E.; Rogov, A.; Il'ina, E.; Larionova, L.; Skuridin, V.; Dergilev, A.

    2016-06-01

    Purpose: to study the potential utility of 1-thio-D-glucose labeled with 99mTc for cancer imaging in laboratory animals. Materials and method: the study was carried out in cell cultures of normal CHO (Chinese hamster ovary cells CHO) and malignant tissues MCF-7 (human breast adenocarcinoma MCF-7). To evaluate the uptake of 99mTc-1-thio-D-glucose in normal and tumor tissue cells, 25 MBq of 1-thio-D-glucose labeled with 99mTc was added to the vials with 3 million cells and incubated for 30 minutes at room temperature. After centrifugation of the vials with cells, the supernatant was removed. Radioactivity in vials with normal and tumor cells was then measured. In addition, the study included 40 mice of C57B 1/6j lines with tumor lesion of the right femur. For neoplastic lesions, Lewis lung carcinoma model was used. Following anesthesia, mice were injected intravenously with 25MBq of 99mTc-1-thio-D-glucose. Planar scintigraphy was performed 15 minutes later in a matrix of 512x512 pixels for 5 minutes. Results: when measuring the radioactivity of normal and malignant cells after incubation with 99mTc-1-thio-D- glucose, it was found that the radioactivity of malignant cells was higher than that of normal cells. The mean values of radioactivity levels in normal and malignant cells were 0.3±0.15MBq and 1.07±0.6MBq, respectively. All examined animals had increased accumulation of 99mTc-1-thio- D-glucose at the tumor site. The accumulation of 99mTc-1-thio-D-glucose in the tumor was on average twice as high as compared to the symmetric region. Conclusion: The present study demonstrated that 99mTc-1-thio-D-glucose is a prospective radiopharmaceutical for cancer visualization. In addition, high accumulation of 99mTc-1-thio-D-glucose in the culture of cancer cells and in tumor tissue of animals demonstrates tumor tropism of the radiopharmaceutical.

  11. Study of potential utility of new radiopharmaceuticals based on technetium-99m labeled derivative of glucose

    NASA Astrophysics Data System (ADS)

    Zeltchan, R.; Medvedeva, A.; Sinilkin, I.; Chernov, V.; Stasyuk, E.; Rogov, A.; Il'ina, E.; Larionova, L.; Skuridin, V.

    2016-08-01

    Purpose: to study the potential utility of 1-thio-D-glucose labeled with 99mTc for cancer imaging in laboratory animals. Materials and method: the study was carried out in cell cultures of normal CHO (Chinese hamster ovary cells CHO) and malignant tissues MCF-7 (human breast adenocarcinoma MCF-7). To evaluate the uptake of 99mTc-1-thio-D-glucose in normal and tumor tissue cells, 25 MBq of 1-thio-D-glucose labeled with 99mTc was added to the vials with 3 million cells and incubated for 30 min at room temperature. After centrifugation of the vials with cells, the supernatant was removed. The radioactivity in vials with normal and tumor cells was then measured. In addition, the study included 40 mice of C57B1/6j lines with tumor lesion of the right femur. For neoplastic lesions, Lewis lung carcinoma model was used. Following anesthesia, mice were injected intravenously with 25 MBq of 99mTc-1-thio-D-glucose. Planar scintigraphy was performed 15 minutes later in a matrix of 512x512 pixels for 5 min. Results: when measuring the radioactivity of normal and malignant cells after incubation with 99mTc-1-thio-D-glucose, it was found that the radioactivity of malignant cells was higher than that of normal cells. The mean values of radioactivity levels in normal and malignant cells were 0.3 ± 0.15 MBq and 1.07 ± 0.6 MBq, respectively. All examined animals had increased accumulation of 99mTc-1-thio-D-glucose at the tumor site. The accumulation of 99mTc-1-thio-D-glucose in the tumor was on average twice as high as compared to the symmetric region. Conclusion: The present study demonstrated that 99mTc-1-thio-D-glucose is a prospective radiopharmaceutical for cancer visualization. In addition, high accumulation of 99mTc-1-thio-D-glucose in the culture of cancer cells and in tumor tissue of animals demonstrates tumor tropism of the radiopharmaceutical.

  12. Radiopharmaceutical considerations for using Tc-99m MAA in lung transplant patients.

    PubMed

    Ponto, James A

    2010-01-01

    To elucidate radiopharmaceutical considerations for using technetium Tc-99m albumin aggregated (Tc-99m MAA) in lung transplant patients and to establish an appropriate routine dose and preparation procedure. Tertiary care academic hospital during May 2007 to May 2009. Nuclear pharmacist working in nuclear medicine department. Radiopharmaceutical considerations deemed important for the use of Tc-99m MAA in lung transplant patients included radioactivity dose, particulate dose, rate of the radiolabeling reaction (preparation time), and final radiochemical purity. Evaluation of our initial 12-month experience, published literature, and professional practice guidelines provided the basis for establishing an appropriate dose and preparation procedure of Tc-99m MAA for use in lung transplant patients. Radiochemical purity at typical incubation times and image quality in subsequent lung transplant patients imaged during the next 12 months. Based on considerations of radioactivity dose, particulate dose, rate of the radiolabeling reaction (preparation time), and final radiochemical purity, a routine dose consisting of 3 mCi (111 MBq) and 100,000 particles of Tc-99m MAA for planar perfusion lung imaging of adult lung transplant patients was established as reasonable and appropriate. MAA kits were prepared with a more reasonable amount of Tc-99m and yielded high radiochemical purity values in typical incubation times. Images have continued to be of high diagnostic quality. Tc-99m MAA used for lung transplant imaging can be readily prepared with high radiochemical purity to provide a dose of 3 mCi (111 GBq)/100,000 particles, which provides images of high diagnostic quality.

  13. Technetium-99m diethylenetriaminepentaacetic acid radioaerosol scintigraphy in organophosphate induced pulmonary toxicity: experimental study.

    PubMed

    Yavuz, Yucel; Kaya, Eser; Yurumez, Yusuf; Sahin, Onder; Bas, Orhan; Fidan, Huseyin; Sezer, Murat

    2008-09-01

    The aim of this experimental study was to investigate pathological signs of lung damages caused by acute organophosphate (OP) poisoning by using Tc-99m DTPA radioaerosol scintigraphy and histopathological investigation. Fourteen rabbits were divided into two equal groups (n = 7). Group 1 (control group) received normal saline (same volume of fenthion, 2 ml/kg) via orogastric tube. Group 2 (OP toxicity group) received 150 mg/kg of fenthion (diluted fenthion, 2 ml/kg) via orogastric tube. Six hours later, Tc-99m-DTPA aerosol inhalation lung scintigraphy was performed in both groups. Then all rabbits were anesthetized with ketamine hydrochloride (35 mg/kg, i.p.) and xysilazine (5 mg/kg, i.p.), and sacrificed by intracardiac blood discharge. The lungs were then removed. There was a significant difference in T1/2 values of Tc-99m DTPA clearance between control group and OP toxicity group (p = 0.04). Intraparenchymal vascular congestion and thrombosis, intraparenchymal hemorrhage, respiratory epithelial proliferation, number of macrophages in the alveolar, and bronchial lumen, alveolar destruction, emphysematous changes, and bronchoalveolar hemorrhage scores were significantly higher in the rabbits exposed to OP compared with the control group (p < 0.05). This study showed that OP toxicity caused a decrease in the alveolar clearance. Tc-99m DTPA radioaerosol inhalation lung scintigraphy was found to be a sensitive determination of acute lung damage in OP poisoning.

  14. 99mTc-D(LPR): A novel retro-inverso peptide for VEGF receptor-1 targeted tumor imaging.

    PubMed

    Rezazadeh, Farzaneh; Sadeghzadeh, Nourollah; Abedi, Seyed Mohammad; Abediankenari, Saeid

    2018-05-31

    The aim of this study was to evaluate the ability of D (LPR), a novel retro-inverso peptidomimetic derivative for imaging colon cancer. Two different D (LPR) analogs were designed and compared based on conjugation of HYNIC at peptide's C or N terminal and then labeled with technetium-99m using tricine/EDDA as an exchange coligands. The radiolabeled conjugates were assessed for in vitro stability in saline and serum. The VEGFR-1 and NRP-1 receptors affinity, in vitro internalization and also dissociation Constance was evaluated. SPCET imaging and biodistribution studies were performed in nude mice bearing HT-29 xenograft tumors. Both peptides labeled with technetium-99m in high radiochemical yield (˃97%). Peptide stability studies indicated a high metabolic stability of the radiopeptides in solution and serum. In vitro blocking studies demonstrated specific binding and internalization of [ 99m Tc]Tc-HYNIC-peptides in cultured HUVEC cells. The K d value for 99m Tc-peptide 1 and 99m Tc-peptide 2 were found to be 56.8 ± 12.9 nM and 71.6 ± 17.9 nM respectively. The tumor to muscle ratio was significant at 0.5 and 1 h after injection (4.5 and 4 for 99m Tc-peptide 1 and 4.9 and 4.4 for 99m Tc-peptide 2 at 0.5 and 1 h p.i. respectively). SPECT imaging studies revealed that both radioconjugates had prominent activity accumulation in VEGFR-1 and NRP-1 expressing HT-29 tumors. This study is the first instance of using a radiolabeled retro-inverso peptide for tumor imaging which is a promising tool to improve the performance of fragile peptide probes in vivo as imaging agents and warrant further investigations in other peptide-target systems. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. 2-Phenylbenzothiazole conjugated with cyclopentadienyl tricarbonyl [CpM(CO)3] (M = Re, (99m)Tc) complexes as potential imaging probes for β-amyloid plaques.

    PubMed

    Jia, Jianhua; Cui, Mengchao; Dai, Jiapei; Liu, Boli

    2015-04-14

    Technetium-99m-labeled cyclopentadienyl tricarbonyl complexes conjugated with the 2-phenylbenzothiazole binding motif were synthesized. The rhenium surrogates , , and were demonstrated to have moderate to high affinities for Aβ1-42 aggregates with Ki values of 142, 76, 64 and 24 nM, respectively. During the fluorescence staining of brain sections of transgenic mice and patients with Alzheimer's disease, these rhenium complexes demonstrated perfect and intense labeling of Aβ plaques. Moreover, in in vitro autoradiography, (99m)Tc-labeled complexes clearly detected β-amyloid plaques on sections of brain tissue from transgenic mice, which confirmed the sufficient affinity of these tracers for Aβ plaques. However, these compounds did not show desirable properties in vivo, especially showing poor brain uptake (below 0.5% ID g(-1)), which will hinder the further development of these tracers as brain imaging agents. Nonetheless, it is encouraging that these (99m)Tc-labeled complexes designed by a conjugate approach displayed sufficient affinities for Aβ plaques.

  16. Assessment of antioxidative ability in brain: Imaging of glutathione localization with technetium-99M meso-hexamethyl propyleneamine oxime

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sasaki, T.; Toyama, H.; Oda, K.

    1994-05-01

    An oxidative stress is postulated to be important in tissue injury after ischemia and reperfusion, inflammation, aging and various disease. Glutathione (GSH), one of the major antioxidants in the brain, is presumed to be responsible for the metabolism and retention of [Tc-99m] HM-PAO. In order to visualize the regional localization of GSH in the brain, the relationship between the concentrations of tissue GSH and uptake of [Tc-99m] meso-HM-PAO and [Tc-99m] d,l-HM-PAO was studied in mice. Increasing load of diethyl maleate (DEM), a reducing agent of GSH and several other thiols, before [Tc-99m] meso-HM-PAO injection, led to a dose dependent decreasemore » of GSH and [Tc-99m] meso-HM-PAO. At the highest dose of loaded DEM, the uptake of [Tc-99m] meso-HM-PAO in the brain was decreased to 20-30% of the control. In contrast, pretreatment with DEM did little affect the [Tc-99m] d,l-HM-PAO uptake. To elucidate the retention mechanism of [Tc-99m] HM-PAO in brain, we studied the in vitro interactions of [Tc-99m] meso-HMPAO and [Tc-99m] d,l-HM-PAO with GSH, ascorbate and cysteine by measuring octanol-extractable radioactivity, which is remaining intact [Tc-99m] HM-PAO, as a function of incubation period. The disappearance raw of [Tc-99m] meso-HMPAO and [TC-99m] d,l-HM-PAO were 0.18 and 0.96%/min, respectively. Either meso or d,l-isomer did not interact with ascorbate or cysteine. This result suggested that the retention mechanism of [Tc-99m] meso- and d,l-isomers in brain was related to their specific interaction with GSH, and did not related to non-specific interaction with various thiols or other reducing agents. This extremely high reaction rate of [Tc-99m] d,l-HM-PAO with GSH could explain the capability of a small amount of GSH to trap [Tc-99m] d,l-HM-PAO in maximum DEM loading. These results indicated that [Tc-99m] meso-HMPAO would be suitable to image the concentration of GSH in the brain, as opposed d,l-isomer that images blood flow.« less

  17. Study of potential utility of new radiopharmaceuticals based on technetium-99m labeled derivative of glucose

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zeltchan, R., E-mail: r.zelchan@yandex.ru; Medvedeva, A.; Sinilkin, I.

    Purpose: to study the potential utility of 1-thio-D-glucose labeled with {sup 99m}Tc for cancer imaging in laboratory animals. Materials and method: the study was carried out in cell cultures of normal CHO (Chinese hamster ovary cells CHO) and malignant tissues MCF-7 (human breast adenocarcinoma MCF-7). To evaluate the uptake of {sup 99m}Tc-1-thio-D-glucose in normal and tumor tissue cells, 25 MBq of 1-thio-D-glucose labeled with {sup 99m}Tc was added to the vials with 3 million cells and incubated for 30 min at room temperature. After centrifugation of the vials with cells, the supernatant was removed. The radioactivity in vials with normalmore » and tumor cells was then measured. In addition, the study included 40 mice of C57B1/6j lines with tumor lesion of the right femur. For neoplastic lesions, Lewis lung carcinoma model was used. Following anesthesia, mice were injected intravenously with 25 MBq of {sup 99m}Tc-1-thio-D-glucose. Planar scintigraphy was performed 15 minutes later in a matrix of 512x512 pixels for 5 min. Results: when measuring the radioactivity of normal and malignant cells after incubation with {sup 99m}Tc-1-thio-D-glucose, it was found that the radioactivity of malignant cells was higher than that of normal cells. The mean values of radioactivity levels in normal and malignant cells were 0.3 ± 0.15 MBq and 1.07 ± 0.6 MBq, respectively. All examined animals had increased accumulation of {sup 99m}Tc-1-thio-D-glucose at the tumor site. The accumulation of {sup 99m}Tc-1-thio-D-glucose in the tumor was on average twice as high as compared to the symmetric region. Conclusion: The present study demonstrated that {sup 99m}Tc-1-thio-D-glucose is a prospective radiopharmaceutical for cancer visualization. In addition, high accumulation of {sup 99m}Tc-1-thio-D-glucose in the culture of cancer cells and in tumor tissue of animals demonstrates tumor tropism of the radiopharmaceutical.« less

  18. Update on radionuclide imaging in hepatobiliary disease. [/sup 99m/Tc-labelled acetanilide iminodracetic acid analogues

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosenthall, L.

    1981-05-01

    The recent introduction of technetium Tc 99m-labeled acetanilide iminodiacetic acid (/sup 99m/Tc-IDA) analogues has facilitated the clincal study of the bile flow pathways. A variety of /sup 99m/Tc-IDA derivaties are under investigation. Basically all are metabolized by the hepatocyte and immediately thereafter excreted unconjugated into the biliary tract. Of the various derivatives tested, e.g., dimethyl (lidofenin), diethyl, paraisopropyl (iprofenin), parabutyl (butilfenin), and diisopropyl (disofenin), the last named is the best universal agent at this time. By serial liver imaging the patency of the cystic duct and the integrity of altered cholangiointestinal anatomy can be assessed, leakage of bile and gastricmore » reflux can be disclosed, and medical and surgical jaundice can be distinguished.« less

  19. Development and Pharmacological Evaluation of New Bone-Targeted (99m)Tc-Radiolabeled Bisphosphonates.

    PubMed

    Makris, George; Tseligka, Eirini D; Pirmettis, Ioannis; Papadopoulos, Minas S; Vizirianakis, Ioannis S; Papagiannopoulou, Dionysia

    2016-07-05

    A novel bisphosphonate, 1-(3-aminopropylamino)ethane-1,1-diyldiphosphonic acid (3), was coupled to the tridentate chelators di-2-picolylamine, 2-picolylamine-N-acetic acid, iminodiacetic acid, 3-((2-aminoethyl)thio)-3-(1H-imidazol-4-yl)propanoic acid, and 2-((2-carboxyethyl)thio)-3-(1H-imidazol-4-yl)propanoic acid to form ligands 6, 9, 11, 15, and 19, respectively. Organometallic complexes of the general formula [Re/(99m)Tc(CO)3(κ(3)-L)] were synthesized, where L denotes ligand 6, 9, 11, 15, or 19. The rhenium complexes were prepared at the macroscopic level and characterized by spectroscopic methods. The technetium-99m organometallic complexes were synthesized in high yield and were identified by comparative reversed-phase HPLC with their Re analogues. The (99m)Tc tracers were stable in vitro and exhibited binding to hydroxyapatite. In biodistribution studies, all of the (99m)Tc complexes exhibited high bone uptake superior to that of 25, which is the directly (99m)Tc-labeled bisphosphonate 3, and comparable to that of (99m)Tc-methylene diphosphonate ((99m)Tc-MDP). The tracers [(99m)Tc(CO)3(6)] (26), [(99m)Tc(CO)3(9)] (27), [(99m)Tc(CO)3(11)] (28), and [(99m)Tc(CO)3(15)] (29) exhibited higher bone/blood ratios than (99m)Tc-MDP. 26 had the highest bone uptake at 1 h p.i. The new bisphosphonates showed no substantial growth inhibitory capacity in PC-3, Saos-2, and MCF-7 established cancer cell lines at low concentrations. Incubation of 26 with the same cancer cell lines indicated a rapid and saturated uptake. The promising properties of 26-29 indicate their potential for use as bone-imaging agents.

  20. Kinetic sensitivity of a receptor-binding radiopharmaceutical: Technetium-99m galactosyl-neoglycoalbumin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vera, D.R.; Woodle, E.S.; Stadalnik, R.C.

    1989-09-01

    Kinetic sensitivity is the ability of a physiochemical parameter to alter the time-activity curve of a radiotracer. The kinetic sensitivity of liver and blood time-activity data resulting from a single bolus injection of ({sup 99m}Tc)galactosyl-neoglycoalbumin (( Tc)NGA) into healthy pigs was examined. Three parameters, hepatic plasma flow scaled as flow per plasma volume, ligand-receptor affinity, and total receptor concentration, were tested using (Tc)NGA injections of various molar doses and affinities. Simultaneous measurements of plasma volume (iodine-125 human serum albumin dilution), and hepatic plasma flow (indocyanine green extraction) were performed during 12 (Tc)NGA studies. Paired data sets demonstrated differences (P(chi v2)more » less than 0.01) in liver and blood time-activity curves in response to changes in each of the tested parameters. We conclude that the (Tc)NGA radiopharmacokinetic system is therefore sensitive to hepatic plasma flow, ligand-receptor affinity, and receptor concentration. In vivo demonstration of kinetic sensitivity permits delineation of the physiologic parameters that determine the biodistribution of a radiopharmaceutical. This delineation is a prerequisite to a valid analytic assessment of receptor biochemistry via kinetic modeling.« less

  1. Synthesis of Tc-99m labeled 1,2,3-triazole-4-yl c-met binding peptide as a potential c-met receptor kinase positive tumor imaging agent.

    PubMed

    Kim, Eun-Mi; Joung, Min-Hee; Lee, Chang-Moon; Jeong, Hwan-Jeong; Lim, Seok Tae; Sohn, Myung-Hee; Kim, Dong Wook

    2010-07-15

    The mesenchymal-epithelial transition factor (c-Met), which is related to tumor cell growth, angiogenesis and metastases, is known to be overexpressed in several tumor types. In this study, we synthesized technetium-99m labeled 1,2,3-triazole-4-yl c-Met binding peptide (cMBP) derivatives, prepared by solid phase peptide synthesis and the 'click-to-chelate' protocol for the introduction of tricarbonyl technetium-99m, as a potential c-Met receptor kinase positive tumor imaging agent, and evaluated their in vitro c-Met binding affinity, cellular uptake, and stability. The (99m)Tc labeled cMBP derivatives ([(99m)Tc(CO)(3)]12, [(99m)Tc(CO)(3)]13, and [(99m)Tc(CO)(3)]14) were prepared in 85-90% radiochemical yields. The cold surrogate cMBP derivatives, [Re(CO)(3)]12, [Re(CO)(3)]13, and [Re(CO)(3)]14, were shown to have high binding affinities (0.13 microM, 0.06 microM, and 0.16 microM, respectively) to a purified cMet/Fc chimeric recombinant protein. In addition, the in vitro cellular uptake and inhibition studies demonstrated the high specific binding of these (99m)Tc labeled cMBP derivatives ([(99m)Tc(CO)(3)]12-14) to c-Met receptor positive U87MG cells. 2010 Elsevier Ltd. All rights reserved.

  2. Rapid and accurate diagnosis of acute cholecystitis with /sup 99m/Tc-HIDA cholescintigraphy. [HIDA = dimethyl acetanilide iminodiacetic acid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weissmann, H.S.; Frank, M.S.; Bernstein, L.H.

    1979-04-01

    Technetium-99m dimethyl acetanilide iminodiacetic acid (HIDA) cholescintigraphy was performed on 90 patients with suspected acute cholecytitis. Visualization of the gallbladder established patency of the cystic duct and excluded the diagnosis of acute cholecystitis in 50 of 52 patients. Nonvisualization of the gallbladder with visualization of the common bile duct was diagnostic of acute cholecystitis in 38 patients, all subsequently proven at surgery. The observed accuracy of this procedure is 98% and specificity is 100%. The false negative rate is 5% and false positive rate is zero. Technetium-99m-HILDA has many advantages which make it the procedure of choice in evaluating amore » patient for suspected acute cholecystitis. It is a rapid, simple, safe examination which provides functional as well as anatomic information about the hepatobiliary system in individuals with a serum bilirubin level up to 8 mg/100 ml.« less

  3. Regional brain hematocrit in stroke by single photon emission computed tomography imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loutfi, I.; Frackowiak, R.S.; Myers, M.J.

    1987-01-01

    Nineteen studies on 18 subjects were performed by single photon emission computed tomography (SPECT) of the head after the successive intravenous administration of a plasma label (/sup 99m/Tc-human serum albumin (HSA)) and /sup 99m/Tc-labeled autologous red blood cells (RBC). Two sets of cerebral tomographic sections were generated: for cerebral /sup 99m/Tc-HSA alone and for combined /sup 99m/Tc-HSA and /sup 99m/Tc-RBC. By relating counts in regions of interest from the cerebral tomograms to counts from blood samples obtained during each tomographic acquisition, regional cerebral haematocrit (Hct) was calculated by the application of a simple formula. Results show 1) lower cerebral Hctmore » than venous Hct (ratio of HCT brain/Hct venous 0.65-0.90) in all subjects, and 2) comparison between right and left hemisphere Hct in 3/3 normal subjects, 6/6 patients with transient ischaemic attacks and 3/8 patients with stroke showed no significant difference. However, in 3/8 patients with stroke (most recent strokes) significant differences were found, the higher Hct value corresponding to the affected side.« less

  4. In vitro and in vivo comparison of binding of 99m-Tc-labeled anti-CEA MAb F33-104 with 99m-Tc-labeled anti-CEA MAb BW431/26.

    PubMed

    Watanabe, N; Oriuchi, N; Sugiyama, S; Kuroki, M; Matsuoka, Y; Tanada, S; Murata, H; Inoue, T; Sasaki, Y

    1999-01-01

    The purpose of this study was to assess the potential for radio-immunodetection (RAID) of murine anti-carcinoembryonic antigen (CEA) monoclonal antibody (MAb) F33-104 labeled with technetium-99m (99m-Tc) by a reduction-mediated labeling method. The binding capacity of 99m-Tc-labeled anti-CEA MAb F33-104 with CEA by means of in vitro procedures such as immunoradiometric assay and cell binding assay and the biodistribution of 99m-Tc-labeled anti-CEA MAb F33-104 in normal nude mice and nude mice bearing human colon adenocarcinoma LS180 tumor were investigated and compared with 99m-Tc-labeled anti-CEA MAb BW431/26. The in vitro binding rate of 99m-Tc-labeled anti-CEA MAb F33-104 with CEA in solution and attached to the cell membrane was significantly higher than 99m-Tc-labeled anti-CEA MAb BW431/261 (31.4 +/- 0.95% vs. 11.9 +/- 0.55% at 100 ng/mL of soluble CEA, 83.5 +/- 2.84% vs. 54.0 +/- 2.54% at 10(7) of LS 180 cells). In vivo, accumulation of 99m-Tc-labeled anti-CEA MAb F33-104 was higher at 18 h postinjection than 99m-Tc-labeled anti-CEA MAb BW431/26 (20.1 +/- 3.50% ID/g vs. 14.4 +/- 3.30% ID/g). 99m-Tc-activity in the kidneys of nude mice bearing tumor was higher at 18 h postinjection than at 3 h (12.8 +/- 2.10% ID/g vs. 8.01 +/- 2.40% ID/g of 99m-Tc-labeled anti-CEA MAb F33-104, 10.7 +/- 1.70% ID/g vs. 8.10 +/- 1.75% ID/g of 99m-Tc-labeled anti-CEA MAb BW431/26). 99m-Tc-labeled anti-CEA MAb F33-104 is a potential novel agent for RAID of recurrent colorectal cancer.

  5. Novel Approach to Prepare {sup 99m}Tc-Based Multivalent RGD Peptides

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shuang Liu

    2012-10-24

    This project presents a novel approach to prepare the {sup 99m}Tc-bridged multivalent RGD (arginine-glycine-aspartate) peptides. This project will focus on fundamentals of {sup 99m}Tc radiochemistry. The main objective of this project is to demonstrate the proof-of-principle for the proposed radiotracers. Once a kit formulation is developed for preparation of the {sup 99m}Tc-bridged multivalent RGD peptides, various tumor-bearing animal models will be used to evaluate their potential for SPECT (single photon-emission computed tomography) imaging of cancer. We have demonstrated that (1) multimerization of cyclic RGD peptides enhances the integrin {alpha}{sub v}{beta}{sub 3} bonding affinity and radiotracer tumor uptake; (2) addition ofmore » G{sub 3} or PEG{sub 4} linkers makes it possible for two RGD motifs in 3P-RGD{sub 2} and 3G-RGD{sub 2} to achieve simultaneous integrin {alpha}{sub v}{beta}{sub 3} binding; and (3) multimers are actually bivalent (not multivalent), the presence of extra RGD motifs can enhance the tumor retention time of the radiotracer.« less

  6. Rhenium and technetium tricarbonyl, {M(CO)3} (+) (M = Tc, Re), binding to mammalian metallothioneins: new insights into chemical and radiopharmaceutical implications.

    PubMed

    Lecina, Joan; Palacios, Òscar; Atrian, Sílvia; Capdevila, Mercè; Suades, Joan

    2015-04-01

    This paper deals with the binding of the four mammalian metallothioneins (MTs) to the organometallic metal fragment {fac-M(CO)3}(+) (M = (99)Tc, Re), which is highly promising for the preparation of second-generation radiopharmaceuticals. The study of the transmetallation reaction between zinc and rhenium in Zn7-MT1 by means of UV-vis and CD spectroscopy demonstrated the incorporation of the {fac-Re(CO)3}(+) fragment to the MTs. This reaction should be performed at 70 °C to accelerate the reaction rate, a result that is consistent with the reported reactivity of the rhenium fragment. ESI-TOF MS demonstrated the formation of mixed-metal species as Zn6,{Re(CO)3}-MT, Zn6,{Re(CO)3}2-MT, and Zn5,{Re(CO)3}3-MT, as well as the different reactivity of the four MT isoforms. Hence, Zn-MT3 showed the highest reactivity, in agreement with its high Cu-thionein character, whereas Zn-MT2 exhibited the lowest reactivity, in line with its high Zn-thionein character. The reactivity of the Zn-loaded forms of MT1 and MT4 is intermediate between those of MT3 and MT2. The study of the binding of the {fac-(99)Tc(CO)3}(+) fragment to MTs showed a significant and very interesting different reactivity in relation to rhenium. The transmetallation reaction is much more effective with technetium than with rhenium and significant amounts of mixed Zn x ,{(99)Tc(CO)3} y -MT species were formed with the four MT isoforms whereas only MT3 rendered similar amounts of rhenium derivatives. The results obtained in this study support the possible use of technetium for labelling mammalian metallothioneins and also for possible radiopharmaceutical applications.

  7. Semi-Quantitative Analysis of Post-Transarterial Radioembolization (90)Y Microsphere Positron Emission Tomography Combined with Computed Tomography (PET/CT) Images in Advanced Liver Malignancy: Comparison With (99m)Tc Macroaggregated Albumin (MAA) Single Photon Emission Computed Tomography (SPECT).

    PubMed

    Rhee, Seunghong; Kim, Sungeun; Cho, Jaehyuk; Park, Jukyung; Eo, Jae Seon; Park, Soyeon; Lee, Eunsub; Kim, Yun Hwan; Choe, Jae-Gol

    2016-03-01

    The purpose of this study is to evaluate the correlation between pretreatment planning technetium-99m ((99m)Tc) macroaggregated albumin (MAA) SPECT images and posttreatment transarterial radioembolization (TARE) yttirum-90 ((90)Y) PET/CT images by comparing the ratios of tumor-to-normal liver counts. Fifty-two patients with advanced hepatic malignancy who underwent (90)Y microsphere radioembolization from January 2010 to December 2012 were retrospectively reviewed. Patients had undergone (99m)Tc MAA intraarterial injection SPECT for a pretreatment evaluation of microsphere distribution and therapy planning. After the administration of (90)Y microspheres, the patients underwent posttreatment (90)Y PET/CT within 24 h. For semiquantitative analysis, the tumor-to-normal uptake ratios in (90)Y PET/CT (TNR-yp) and (99m)Tc MAA SPECT (TNR-ms) as well as the tumor volumes measured in angiographic CT were obtained and analyzed. The relationship of TNR-yp and TNR-ms was evaluated by Spearman's rank correlation and Wilcoxon's matched pairs test. In a total of 79 lesions of 52 patients, the distribution of microspheres was well demonstrated in both the SPECT and PET/CT images. A good correlation was observed of between TNR-ms and TNR-yp (rho value = 0.648, p < 0.001). The TNR-yp (median 2.78, interquartile range 2.43) tend to show significantly higher values than TNR-ms (median 2.49, interquartile range of 1.55) (p = 0.012). The TNR-yp showed weak correlation with tumor volume (rho = 0.230, p = 0.041). The (99m)Tc MAA SPECT showed a good correlation with (90)Y PET/CT in TNR values, suggesting that (99m)Tc MAA can be used as an adequate pretreatment evaluation method. However, the (99m)Tc MAA SPECT image consistently shows lower TNR values compared to (90)Y PET/CT, which means the possibility of underestimation of tumorous uptake in the partition dosimetry model using (99m)Tc MAA SPECT. Considering that (99m)Tc MAA is the only clinically available surrogate

  8. Ultrafast time measurements by time-correlated single photon counting coupled with superconducting single photon detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shcheslavskiy, V., E-mail: vis@becker-hickl.de; Becker, W.; Morozov, P.

    Time resolution is one of the main characteristics of the single photon detectors besides quantum efficiency and dark count rate. We demonstrate here an ultrafast time-correlated single photon counting (TCSPC) setup consisting of a newly developed single photon counting board SPC-150NX and a superconducting NbN single photon detector with a sensitive area of 7 × 7 μm. The combination delivers a record instrument response function with a full width at half maximum of 17.8 ps and system quantum efficiency ∼15% at wavelength of 1560 nm. A calculation of the root mean square value of the timing jitter for channels withmore » counts more than 1% of the peak value yielded about 7.6 ps. The setup has also good timing stability of the detector–TCSPC board.« less

  9. Altered [99mTc]Tc-MDP biodistribution from neutron activation sourced 99Mo.

    PubMed

    Demeter, Sandor; Szweda, Roman; Patterson, Judy; Grigoryan, Marine

    2018-01-01

    Given potential worldwide shortages of fission sourced 99 Mo/ 99m Tc medical isotopes there is increasing interest in alternate production strategies. A neutron activated 99 Mo source was utilized in a single center phase III open label study comparing 99m Tc, as 99m Tc Methylene Diphosphonate ([ 99m Tc]Tc-MDP), obtained from solvent generator separation of neutron activation produced 99 Mo, versus nuclear reactor produced 99 Mo (e.g., fission sourced) in oncology patients for which an [ 99m Tc]Tc-MDP bone scan would normally have been indicated. Despite the investigational [ 99m Tc]Tc-MDP passing all standard, and above standard of care, quality assurance tests, which would normally be sufficient to allow human administration, there was altered biodistribution which could lead to erroneous clinical interpretation. The cause of the altered biodistribution remains unknown and requires further research.

  10. Method for the production of .sup.99m Tc compositions from .sup.99 Mo-containing materials

    DOEpatents

    Bennett, Ralph G.; Christian, Jerry D.; Grover, S. Blaine; Petti, David A.; Terry, William K.; Yoon, Woo Y.

    1998-01-01

    An improved method for producing .sup.99m Tc compositions from .sup.99 Mo compounds. .sup.100 Mo metal or .sup.100 MoO.sub.3 is irradiated with photons in a particle (electron) accelerator to ultimately produce .sup.99 MoO.sub.3. This composition is then heated in a reaction chamber to form a pool of molten .sup.99 MoO.sub.3 with an optimum depth of 0.5-5 mm. A gaseous mixture thereafter evolves from the molten .sup.99 MoO.sub.3 which contains vaporized .sup.99 MoO.sub.3, vaporized .sup.99m TcO.sub.3, and vaporized .sup.99m TcO.sub.2. This mixture is then combined with an oxidizing gas (O.sub.2(g)) to generate a gaseous stream containing vaporized .sup.99m Tc.sub.2 O.sub.7 and vaporized .sup.99 MoO.sub.3. Next, the gaseous stream is cooled in a primary condensation stage in the reaction chamber to remove vaporized .sup.99 MoO.sub.3. Cooling is undertaken at a specially-controlled rate to achieve maximum separation efficiency. The gaseous stream is then cooled in a sequential secondary condensation stage to convert vaporized .sup.99m Tc.sub.2 O.sub.7 into a condensed .sup.99m Tc-containing reaction product which is collected.

  11. Method for the production of {sup 99m}Tc compositions from {sup 99}Mo-containing materials

    DOEpatents

    Bennett, R.G.; Christian, J.D.; Grover, S.B.; Petti, D.A.; Terry, W.K.; Yoon, W.Y.

    1998-09-01

    An improved method is described for producing {sup 99m}Tc compositions from {sup 99}Mo compounds. {sup 100}Mo metal or {sup 100}MoO{sub 3} is irradiated with photons in a particle (electron) accelerator to ultimately produce {sup 99}MoO{sub 3}. This composition is then heated in a reaction chamber to form a pool of molten {sup 99}MoO{sub 3} with an optimum depth of 0.5--5 mm. A gaseous mixture thereafter evolves from the molten {sup 99}MoO{sub 3} which contains vaporized {sup 99}MoO{sub 3}, vaporized {sup 99m}TcO{sub 3}, and vaporized {sup 99m}TcO{sub 2}. This mixture is then combined with an oxidizing gas (O{sub 2(g)}) to generate a gaseous stream containing vaporized {sup 99m}Tc{sub 2}O{sub 7} and vaporized {sup 99}MoO{sub 3}. Next, the gaseous stream is cooled in a primary condensation stage in the reaction chamber to remove vaporized {sup 99}MoO{sub 3}. Cooling is undertaken at a specially-controlled rate to achieve maximum separation efficiency. The gaseous stream is then cooled in a sequential secondary condensation stage to convert vaporized {sup 99m}Tc{sub 2}O{sub 7} into a condensed {sup 99m}Tc-containing reaction product which is collected. 1 fig.

  12. Candidate Low-Temperature Glass Waste Forms for Technetium-99 Recovered from Hanford Effluent Management Facility Evaporator Concentrate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ding, Mei; Tang, Ming; Rim, Jung Ho

    Alternative treatment and disposition options may exist for technetium-99 (99Tc) in secondary liquid waste from the Hanford Direct-Feed Low-Activity Waste (DFLAW) process. One approach includes development of an alternate glass waste form that is suitable for on-site disposition of technetium, including salts and other species recovered by ion exchange or precipitation from the EMF evaporator concentrate. By recovering the Tc content from the stream, and not recycling the treated concentrate, the DFLAW process can potentially be operated in a more efficient manner that lowers the cost to the Department of Energy. This report provides a survey of candidate glass formulationsmore » and glass-making processes that can potentially incorporate technetium at temperatures <700 °C to avoid volatilization. Three candidate technetium feed streams are considered: (1) dilute sodium pertechnetate loaded on a non-elutable ion exchange resin; (2) dilute sodium-bearing aqueous eluent from ion exchange recovery of pertechnetate, or (3) technetium(IV) oxide precipitate containing Sn and Cr solids in an aqueous slurry. From the technical literature, promising candidate glasses are identified based on their processing temperatures and chemical durability data. The suitability and technical risk of three low-temperature glass processing routes (vitrification, encapsulation by sintering into a glass composite material, and sol-gel chemical condensation) for the three waste streams was assessed, based on available low-temperature glass data. For a subset of candidate glasses, their long-term thermodynamic behavior with exposure to water and oxygen was modeled using Geochemist’s Workbench, with and without addition of reducing stannous ion. For further evaluation and development, encapsulation of precipitated TcO2/Sn/Cr in a glass composite material based on lead-free sealing glasses is recommended as a high priority. Vitrification of pertechnetate in aqueous anion exchange eluent

  13. Comparison of 99mTc-HYNIC-TOC and HYNIC-TATE octreotide scintigraphy with FDG PET and 99mTc-MIBI in local recurrent or distant metastatic thyroid cancers.

    PubMed

    Sager, Sait; Kabasakal, Levent; Halac, Metin; Maecke, Helmut; Uslu, Lebriz; Önsel, Çetin; Kanmaz, Bedii

    2013-05-01

    There have been various studies for early diagnosis of local recurrent or distant metastatic thyroid cancers. The aim of this study is to evaluate the clinical utility of 99mTc-HYNIC-TOC and 99mTc-HYNIC-TATE, octreotide derivatives, to detect recurrences or distant metastases in 131I-negative thyroglobulin positive thyroid cancer patients and to compare the lesions with FDG PET and 99mTc-MIBI studies in the same patient group. Twenty differentiated thyroid cancer patients, 7 male and 13 female, mean age 54.6 ± 15.3 (range 13-78 years), were included in this study. Eighteen patients had papillary thyroid cancer and 2 had follicular thyroid cancer. Fifteen patients received HYNIC-TOC and 5 patients received HYNIC-TATE as a radiopharmaceutical. All patients underwent whole-body scan 1 and 4 hours after injection of octreotide derivatives and SPECT imagings were performed from the suspicious sites. The lesions that were seen in 99mTc-HYNIC-TOC and 99mTc-HYNIC-TATE studies were compared with 99mTc-MIBI and FDG-PET studies. Among 99mTc-HYNIC-TOC and 99mTc-HYNIC-TATE scintigraphies, 15 patient studies were evaluated as true positive (75%) and 5 were false negative (25%). The total number of lesions in octreotide scintigraphy was 48 in 20 patients. Of 20 patients, 19 had FDG-PET study, 15 of them were evaluated as true positive (78.9%), and 4 them were evaluated as false negative (21.1%). Total number of lesions in FDG PET was 74. 99mTc-MIBI study was positive in 11 patients (55%) and negative in 9 patients (45%). Total number of lesions in 99mTc-MIBI was 25. Technetium-labeled somatostatin receptor scintigraphy analogues HYNIC-TOC and HYNIC-TATE are useful imaging alternatives in somatostatin receptor expressing thyroid cancer patients. Radiolabeling is easy and they are readily available for routine use.

  14. Method and kit for the selective labeling of red blood cells in whole blood with TC-99M

    DOEpatents

    Srivastava, Suresh C.; Babich, John W.; Straub, Rita; Richards, Powell

    1988-01-01

    Disclosed herein are a method and kit for the preparation of .sup.99m Tc labeled red blood cells using whole blood in a closed sterile system containing stannous tin in a form such that it will enter the red blood cells and be available therein for the reduction of technetium.

  15. Diagnostic value of 99mTc-bombesin scintigraphy for differentiation of malignant from benign breast lesions.

    PubMed

    Shariati, Farzaneh; Aryana, Kamran; Fattahi, Asiehsadat; Forghani, Mohammad N; Azarian, Azita; Zakavi, Seyed R; Sadeghi, Ramin; Ayati, Narjes; Sadri, Keyvan

    2014-06-01

    In this study, we evaluated the diagnostic accuracy of (99m)Tc-bombesin scintigraphy for differentiation of benign from malignant palpable breast lesions. (99m)Tc-Bombesin is a tracer with high affinity for gastrin-releasing peptide receptor, which is overexpressed on a variety of human tumors including breast carcinoma. We examined 33 consecutive women who were referred to our center with suspicious palpable breast lesions but had no definitive diagnosis in other imaging procedures. A volume of 370-444 MBq of (99m)Tc-bombesin was injected and dynamic 1-min images were taken for 20 min immediately after injection in anterior view. Thereafter, two static images in anterior and prone-lateral views were taken for 5 min. Finally, single-photon emission computed tomography images were taken for each patient. Definitive diagnosis was based on biopsy and histopathological evaluation. The scan findings were positive in 19 patients and negative in 11 on visual assessment of the planar and single-photon emission computed tomography images. Pathologic examination confirmed breast carcinoma in 12 patients with positive scans and benign pathology for 18 patients. The overall sensitivity, specificity, negative and positive predictive values, and accuracy of this radiotracer for diagnosis of breast cancer were 100, 66.1, 100, 63, and 76%, respectively. Semiquantitative analysis improved the specificity of the visual assessment from 66 to 84%. Our study showed that (99m)Tc-bombesin scintigraphy has a high sensitivity and negative predictive value for detecting malignant breast lesions, but the specificity and positive predictive value of this radiotracer for differentiation of malignant breast abnormalities from benign ones are relatively low.

  16. Tc-99m imaging in thyroidectomized differentiated thyroid cancer patients immediately before I-131 treatment.

    PubMed

    Tsai, Chi-Jung; Cheng, Cheng-Yi; Shen, Daniel Hueng-Yuan; Kuo, Shou Jen; Wang, Lien-Yen; Lee, Chiang-Hsuan; Wang, Jhi-Joung; Chang, Ming-Che; Huang, Wen-Sheng

    2016-02-01

    The aim of this study was to evaluate the clinical role of technetium-99m pertechnetate (Tc-99m) imaging in thyroidectomized differentiated thyroid cancer patients immediately before radioiodine-131 (I-131) treatment (Tx). Eighty-six consecutive post-total-thyroidectomy patients (15 men, 71 women; mean age: 46.8 years) with pathologically diagnosed differentiated thyroid cancer were retrospectively studied. Tc-99m imaging immediately before I-131 Tx using both patient-based and lesion-based measurements were analyzed and were further compared with those of post-Tx I-131 whole-body scans. For patients with unequivocally positive Tc-99m uptake, the sensitivity was 77% (patient-based) and 59% (site-based). The positive predictive value (PPV) was 100% for both patient-based and site-based measurements. If equivocal Tc-99m uptake was counted as positive, the sensitivity was 83 and 67%, and the PPV was 100 and 99% for patient-based and site-based measurements, respectively. (a) To increase sensitivity yet maintaining high PPV, equivocal Tc-99m uptake should be considered a positive finding. (b) The nearly 100% PPV of Tc-99m imaging immediately before I-131 Tx for remnant detection suggests that Tc-99m imaging not only serves as an alternative to low-dose I-131 scanning in the low-risk post-thyroidectomy patients but also provides a clue for the subsequent I-131 therapeutic dosage and even for the outcome prediction.

  17. Method and kit for the selective labeling of red blood cells in whole blood with Tc-99m

    DOEpatents

    Srivastava, S.C.; Babich, J.W.; Straub, R.; Richards, P.

    1988-07-05

    Disclosed herein are a method and kit for the preparation of [sup 99m]Tc labeled red blood cells using whole blood in a closed sterile system containing stannous tin in a form such that it will enter the red blood cells and be available for the reduction of technetium. No Drawings

  18. Technetium-99m-HMPAO as a marker of chemical and irradiation lung injury: Experimental and clinical investigations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Suga, Kazuyoshi; Uchisako, Hiromichi; Nishigauchi, Kazuya

    1994-09-01

    The authors evaluated the ability of {sup 99m}Tc-hexamethylpropyleneamine oxime ({sup 99m}Tc-HMPAO) to serve as a sensitive marker of lung injury. Two experiment rabbit models of minimal lung injury were designed using injections of a low dose (0.05 ml/kg) of oleic acid or 50 Gy of irradiation. In addition, they clinically investigated whether patients who received chemotherapy (n = 14) or radiotherapy (n = 13) for lung cancer showed high uptake of {sup 99m}Tc-HMPAO in the lungs. Despite the minimal endothelial lesions visualized by electron microscopy (edematous changes and blebbing), in both animal models, the lungs showed high uptake of {supmore » 99m}Tc-HMPAO, which occurred rapidly within 1 min after injection. Clinically, the mean lung-to-liver ratio of {sup 99m}Tc-HMPAO activity in the patients who received chemotherapy (0.649{+-}0.185, p < 0.01) was significantly higher than that of the controls (n = 16; 0.387{+-}0.108), and all 12 patients who received more than 30 Gy of irradiation showed abnormal uptake in the irradiated lungs, despite the lack of abnormal opacities on chest CT. These findings suggest that {sup 99m}Tc-HMPAO has the potential to be a sensitive marker of chemical and irradiation lung injury. 53 refs., 5 figs., 3 tabs.« less

  19. Radioguided localisation of impalpable breast lesions using 99m-Technetium macroaggregated albumin: Lessons learnt during introduction of a new technique to guide preoperative localisation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Landman, Joanne; Kulawansa, Sagarika; McCarthy, Michael

    2015-03-15

    Preoperative wire-guided localisation (WGL) of impalpable breast lesions is widely used but can be technically difficult. Risks include wire migration, inaccurate placement, and inadequate surgical margins. Research shows that radioguided occult lesion localisation (ROLL) is quicker, easier, and can improve surgical and cosmetic outcomes. An audited introduction of ROLL was conducted to validate the technique as a feasible alternative to WGL. Fifty patients with single impalpable lesions and biopsy proven malignancy or indeterminate histology underwent WGL followed by intralesional radiopharmaceutical injection of 99m-Technetium macroaggregated albumin. Postprocedural mammography was performed to demonstrate wire position, and scintigraphy to evaluate radiopharmaceutical migration. Lymphoscintigraphymore » and intraoperative sentinel node biopsy were performed if indicated, followed by lesion localisation and excision using a gamma probe. Specimen imaging was performed, with immediate reexcision for visibly inadequate margins. Accurate localisation was achieved in 86% of patients with ROLL compared to 72% with WGL. All lesions were successfully removed, with clear margins in 71.8% of malignant lesions. Reexcision and intraoperative sentinel node localisation rates were equivalent to preaudit figures for WGL. ROLL was easy to perform and problems were infrequent. Inaccurate radiopharmaceutical placement necessitating WGL occurred in four patients. Minor radiopharmaceutical migration was common, but precluded using ROLL in only two cases. ROLL is effective, simple, inexpensive, and easily learnt; however, preoperative confirmation of correct radiopharmaceutical placement using mammography and the gamma probe is important to help ensure successful lesion removal. Insertion of a backup hookwire is recommended during the initial introduction of ROLL.« less

  20. Use of 99mTc-Tilmanocept as a Single Agent for Sentinel Lymph Node Identification in Breast Cancer: A Retrospective Pilot Study.

    PubMed

    Unkart, Jonathan T; Wallace, Anne M

    2017-09-01

    99m Tc-tilmanocept received recent Food and Drug Administration approval for lymphatic mapping in 2013. However, to our knowledge, no prior studies have evaluated the use of 99m Tc-tilmanocept as a single agent in sentinel lymph node (SLN) biopsy in breast cancer. Methods: We executed this retrospective pilot study to assess the ability of 99m Tc-tilmanocept to identify sentinel nodes as a single agent in clinically node-negative breast cancer patients. Patients received a single intradermal injection overlying the tumor of either 18.5 MBq (0.5 mCi) of 99m Tc-tilmanocept on the day of surgery or 74.0 MBq (2.0 mCi) on the day before surgery by a radiologist. Immediate 3-view lymphoscintigraphy was performed. Intraoperatively, SLNs were identified with a portable γ-probe. A node was classified as hot if the count (per second) of the node was more than 3 times the background count. Descriptive statistics are reported. Results: Nineteen patients underwent SLN biopsy with single-agent 99m Tc-tilmanocept. Immediate lymphoscintigraphy identified at least 1 sentinel node in 13 of 17 patients (76.5%). Intraoperatively, at least 1 (mean, 1.7 ± 0.8; range, 1-3) hot node was identified in all patients. Three patients (15.8%) had 1 disease-positive SLN. Conclusion: In this small, retrospective pilot study, 99m Tc-tilmanocept performed well as a single agent for intraoperative sentinel node identification in breast cancer. A larger, randomized clinical trial is warranted to compare 99m Tc-tilmanocept as a single agent with other radiopharmaceuticals for sentinel node identification in breast cancer. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  1. Organ distribution of technetium-99m-labeled Corynebacterium parvum in normal and tumor-bearing mice

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barth, R.F.; Singla, O.

    1978-01-01

    The distribution patterns were studied for /sup 99m/Tc-labeled Corynebacterium parvum in normal and tumor-bearing mice. C57BL/6 mice were given i.v., i.p., or s.c. injections of 250 ..mu..g of /sup 99m/Tc-labeled C. parvum and killed at 10 min, 1, 4, and 24 hr. After iv. administration, labeled organisms were distributed primarily to the liver, the lungs, and the blood (46% of injected dose), followed by the gastrointestinal tract, the spleen, and the kidneys (11%). Total recoverable radioactivity, which was defined as the percentage of injected dose that was recovered, ranged from 59% at 10 min to 15% at 24 hr. Inmore » contrast to this, /sup 99m/TcS colloid, an inert particulate material, was localized almost entirely in the liver, and the amount recoverable remained constant over 24 hr. One hr after i.p. administration of /sup 99m/Tc-labeled C. parvum, the gastrointestinal tract accounted for 27% of the injected radioactivity, followed by liver, blood, and spleen (12%). This was rapidly excreted between 4 and 24 hr, at which time only 12% of the injected dose was recovered. The skin accounted for 54.6% of the injected radioactivity 1 hr after s.c. injection, 6% 4 hr after s.c. injection, and 0.8% at 24 hr after s.c. injection.« less

  2. High-performance imaging of stem cells using single-photon emissions

    NASA Astrophysics Data System (ADS)

    Wagenaar, Douglas J.; Moats, Rex A.; Hartsough, Neal E.; Meier, Dirk; Hugg, James W.; Yang, Tang; Gazit, Dan; Pelled, Gadi; Patt, Bradley E.

    2011-10-01

    Radiolabeled cells have been imaged for decades in the field of autoradiography. Recent advances in detector and microelectronics technologies have enabled the new field of "digital autoradiography" which remains limited to ex vivo specimens of thin tissue slices. The 3D field-of-view (FOV) of single cell imaging can be extended to millimeters if the low energy (10-30 keV) photon emissions of radionuclides are used for single-photon nuclear imaging. This new microscope uses a coded aperture foil made of highly attenuating elements such as gold or platinum to form the image as a kind of "lens". The detectors used for single-photon emission microscopy are typically silicon detectors with a pixel pitch less than 60 μm. The goal of this work is to image radiolabeled mesenchymal stem cells in vivo in an animal model of tendon repair processes. Single-photon nuclear imaging is an attractive modality for translational medicine since the labeled cells can be imaged simultaneously with the reparative processes by using the dual-isotope imaging technique. The details our microscope's two-layer gold aperture and the operation of the energy-dispersive, pixellated silicon detector are presented along with the first demonstration of energy discrimination with a 57Co source. Cell labeling techniques have been augmented by genetic engineering with the sodium-iodide symporter, a type of reporter gene imaging method that enables in vivo uptake of free 99mTc or an iodine isotope at a time point days or weeks after the insertion of the genetically modified stem cells into the animal model. This microscopy work in animal research may expand to the imaging of reporter-enabled stem cells simultaneously with the expected biological repair process in human clinical trials of stem cell therapies.

  3. Detecting protein losing enteropathy by Tc-99m dextran scintigraphy: a novel experience.

    PubMed

    Kapoor, Seema; Ratan, Simmi K; Kashyap, Ravi; Mittal, S K; Rajeshwari, K; Rawat, H; Verma, Jyoti

    2002-09-01

    To evaluate protien using enteropathy by Tc-99m dextran scintigraphy. Methods for detecting protein loss from the intestine revolve around fecal nitrogen excretion, the clearance of alpha-1 antitrypsin in stools and by endoscopic biopsy. The diagnosis of protein-losing enteropathy (PLE) can also be established by a scintigraphic method that is noninvasive, simple and requires no patient preparation or motivation. This diagnostic modality can also delineate the site of protein loss, thereby offering a targeted approach, and if need be, surgery. Radiolabelling of a non-protein, noncolloidal, nonparticulate and biofriendly molecule like dextran with Technetium-99m for imaging enteric protein loss was utilized in imaging eight children with PLE. The results were encouraging. The authors advocate the use of this diagnostic tool in identifying patients with PLE, particularly in the pediatric age group.

  4. Association of hyperfunctioning thyroid adenoma with thyroid cancer presenting as "trapping only" nodule at 99mTcO4- scintigraphy.

    PubMed

    dell'Erba, L; Gerundini, P; Caputo, M; Bagnasco, M

    2003-11-01

    Rarely may a non-hyperfunctioning thyroid nodule present as "hot" at Technetium-99m pertechnetate (99mTcO4-) and "cold" at radioiodine scintigraphy at late acquisitions. We report the case of a hyperthyroid female patient whose 99mTcO4- scintigraphy showed two "hot" nodules, whereas Iodide-131 (131I-) revealed a lack of indicator uptake by the larger, and intense uptake by the smaller nodule. The patient underwent surgery: histology demonstrated that the larger nodule, mismatched at pertechnetate vs iodine scintigraphy, was a papillary carcinoma. Our suggestion is to perform thyroid scintigraphy with radioiodine in hyperthyroid patients with more than one nodule concentrating pertechnetate, especially when an ultrasonographic pattern possibly suspect for malignancy is present.

  5. The presence of sodium nitrate in generator eluate decreases the radiochemical purity of 99mTc-sestamibi.

    PubMed

    Métayé, Thierry; Rosenberg, Thierry; Guilhot, Joëlle; Bouin-Pineau, Marie-Hélène; Perdrisot, Rémy

    2012-09-01

    A high radiochemical purity (RCP) is recommended for radiopharmaceutical compounds used in the clinical practice of nuclear medicine. However, some preparations of (99m)Tc-sestamibi contain excess impurities (>6%). To understand the origin of these impurities, we investigated the effect of sodium nitrate on the RCP of sestamibi preparations by testing eluates from 3 commercially available (99m)Tc generators. The sestamibi kits (Stamicis) were reconstituted with (99m)Tc eluate from nitrate-containing wet-column (NCWC), nitrate-free wet-column (NFWC), and nitrate-free dry-column (NFDC) generators. Sodium nitrate was 0.05 mg/mL in eluates from the NCWC generators. The RCP was determined using aluminum oxide sheets as the stationary phase and absolute ethanol as the mobile phase. Succimer, tetrofosmin, oxidronate, exametazine, albumin nanocolloid, and soluble albumin were also tested for their RCP values with eluates from the 3 different (99m)Tc generators. The RCP assessment of (99m)Tc-sestamibi was performed on 127 Stamicis preparations. Significantly lower RCP values were found for Stamicis kits prepared with the NCWC generator than for Stamicis prepared with the NFWC (P < 0.0001) and NFDC (P < 0.0001) generators. The number of Stamicis preparations with an RCP under 94% was greater with the NCWC generator (32 of 53 kits) than with the NFDC (2 of 51 kits) or NFWC (0 of 23 kits) generator. Furthermore, the addition of a 0.05 mg/mL concentration of nitrate in NFWC generator eluates significantly decreased the RCP of the Stamicis preparation. In the absence of nitrate in (99m)Tc eluate, no difference was observed between the RCP values of Stamicis kits prepared with the NFWC and NFDC generators. The (99m)Tc impurities generated by nitrates did not modify the quality of myocardial imaging (normal heart-to-lung ratio, 2.2), probably because these impurities are not in the heart field of view. No other tested (99m)Tc-radiopharmaceutical interfered with nitrates. We

  6. Measuring Single Photons

    Science.gov Websites

    Explore the World of Particle Physics Measuring Single Photons The web pages that follow presume phenomenon and then return to our study of single photon measurement. Your choices include: These choices University of Colorado. A Java applet by Phillip Warner. Dive right into the single photon pages here

  7. Sentinel Lymphadenectomy in Vulvar Cancer Using Near-Infrared Fluorescence From Indocyanine Green Compared With Technetium 99m Nanocolloid.

    PubMed

    Soergel, Philipp; Hertel, Hermann; Nacke, Anna Kaarina; Klapdor, Rüdiger; Derlin, Thorsten; Hillemanns, Peter

    2017-05-01

    Nowadays, sentinel diagnostic is performed using technetium 99m (Tc) nanocolloid as a radioactive marker and sometimes patent blue. In the last years, indocyanine green has been evaluated for sentinel diagnostic in different tumor entities. Indocyanine green is a fluorescent molecule that emits a light signal in the near-infrared band after excitation. Our study aimed to evaluate indocyanine green compared with the criterion-standard Tc-nanocolloid. We included patients with primary, unifocal vulvar cancer of less than 4 cm with clinically node-negative groins in this prospective trial. Sentinel diagnostic was carried out using Tc-nanocolloid, indocyanine green, and patent blue. We examined each groin for light signals from the near-infrared band, for radioactivity, and for blue staining. A sentinel lymph node was defined as a Tc-nanocolloid-positive lymph node. All sentinel lymph nodes and all additional blue or fluorescent lymph nodes were excised and tested and then sent for histologic examination. In all, 27 patients were included in whom we found 91 sentinel lymph nodes in 52 groins. All these lymph nodes were positive for indocyanine green, also giving a sensitivity of 100% (95% confidence interval [CI], 96.0%-100%) compared with Tc-nanocolloid. Eight additional lymph nodes showed indocyanine green fluorescence but no Tc positivity, so that the positive predictive value was 91.9% (95% confidence interval, 84.6%-96.5%). In 1 patient, a false-negative sentinel missed by all 3 modalities was found. Our results show that indocyanine green is a promising approach for inguinal sentinel identification in vulvar cancer with a similar sensitivity as radioactive Tc-nanocolloid and worth to be evaluated in further studies.

  8. Single-Photon Nanoantennas

    PubMed Central

    2017-01-01

    Single-photon nanoantennas are broadband strongly scattering nanostructures placed in the near field of a single quantum emitter, with the goal to enhance the coupling between the emitter and far-field radiation channels. Recently, great strides have been made in the use of nanoantennas to realize fluorescence brightness enhancements, and Purcell enhancements, of several orders of magnitude. This perspective reviews the key figures of merit by which single-photon nanoantenna performance is quantified and the recent advances in measuring these metrics unambiguously. Next, this perspective discusses what the state of the art is in terms of fluoresent brightness enhancements, Purcell factors, and directivity control on the level of single photons. Finally, I discuss future challenges for single-photon nanoantennas. PMID:29354664

  9. A rare case of suprahepatic gall bladder with phocomelia and pancytopenia: detected by tc-99m mebrofenin scintigraphy.

    PubMed

    Rather, Tanveeer Ah; Khan, Shoukat H; Singh, Manjeet; Choh, Naseer A

    2013-01-01

    The possibility of an ectopic gallbladder should always be considered whenever there is a failure to localize it in its normal anatomical position on routine imaging. Although a very rare entity, the anomalous position of gallbladder can result in misinterpretation of imaging findings and create clinical confusion. Awareness of such an anomaly facilitates proper diagnosis and subsequent management. The authors report a very rare case of suprahepatic gallbladder associated with phocomelia, pancytopenia, and splenomegaly in a young 25-year-old female. The suprahepatic gallbladder was initially visualized on Technetium-99m (Tc-99m) Mebrofenin radionuclide hepatobiliary scintigraphy. Subsequent magnetic resonance cholecystopancreatography (MRCP) was also done to confirm the diagnosis.

  10. Experimental Observations of Nuclear Activity in Deuterated Materials Subjected to a Low-Energy Photon Beam

    NASA Technical Reports Server (NTRS)

    Steinetz, Bruce M.; Benyo, Theresa L.; Pines, Vladimir; Pines, Marianna; Forsley, Lawrence P.; Westmeyer, Paul A.; Chait, Arnon; Becks, Michael D.; Martin, Richard E.; Hendricks, Robert C.; hide

    2017-01-01

    Exposure of highly deuterated materials to a low-energy (nom. 2 MeV) photon beam resulted in nuclear activity of both the parent metals of hafnium and erbium and a witness material (molybdenum) mixed with the reactants. Gamma spectral analysis of all deuterated materials, ErD2.8+C36D74+Mo and HfD2+C36D74+Mo, showed that nuclear processes had occurred as shown by unique gamma signatures. For the deuterated erbium specimens, posttest gamma spectra showed evidence of radioisotopes of erbium ((163)Er and (171)Er) and of molybdenum ((99)Mo and (101)Mo) and by beta decay, technetium (99mTc and 101Tc). For the deuterated hafnium specimens, posttest gamma spectra showed evidence of radioisotopes of hafnium (180mHf and 181Hf) and molybdenum ((99)Mo and (101)Mo), and by beta decay, technetium ((99m)Tc and (101)Tc). In contrast, when either the hydrogenated or non-gas-loaded erbium or hafnium materials were exposed to the gamma flux, the gamma spectra revealed no new isotopes. Neutron activation materials showed evidence of thermal and epithermal neutrons. CR-39 solid-state nuclear track detectors showed evidence of fast neutrons with energies between 1.4 and 2.5 MeV and several instances of triple tracks, indicating (is) greater than 10 MeV neutrons. Further study is required to determine the mechanism causing the nuclear activity.

  11. Chiral photonic crystal fibers with single mode and single polarization

    NASA Astrophysics Data System (ADS)

    Li, She; Li, Junqing

    2015-12-01

    Chiral photonic crystal fiber (PCF) with a solid core is numerically investigated by a modified chiral plane-wave expansion method. The effects of structural parameters and chirality strength are analyzed on single-polarization single-mode range and polarization states of guided modes. The simulation demonstrates that the chiral photonic crystal fiber compared to its achiral counterpart possesses another single-circular-polarization operation range, which is located in the short-wavelength region. The original single-polarization operation range in the long-wavelength region extends to the short wavelength caused by introducing chirality. Then this range becomes a broadened one with elliptical polarization from linear polarization. With increase of chirality, the two single-polarization single-mode ranges may fuse together. By optimizing the structure, an ultra-wide single-circular-polarization operation range from 0.5 μm to 1.67 μm for chiral PCF can be realized with moderate chirality strength.

  12. Synthesis and biological evaluation of (99m)Tc-DMP-NGA as a novel hepatic asialoglycoprotein receptor imaging agent.

    PubMed

    Yang, Wenjiang; Mou, Tiantian; Zhang, Xianzhong; Wang, Xuebin

    2010-01-01

    A novel bifunctional coupling agents-biomolecular compound DMP-NGA was prepared by coupling the SATP with galactosyl-neoglycoalbumin (NGA). The DMP-NGA was labeled with technetium-99m, and the radiochemical purity in excess of 98% after purified with HPLC. In vivo biodistribution showed that (99m)Tc-DMP-NGA had very high initial liver uptake with good retention. The liver accumulated 99.35+/-9.77%, 74.25+/-3.03%, 52.47+/-7.58% of the injected dose per gram at 5, 30 and 120min after injection, respectively. It had relative higher initial liver uptake and much lower blood uptake than that of (99m)Tc-GSA. The liver/blood ratio reached 83.4 at 30min post-injection, while the ratio of liver/kidney was 14.4. The uptakes in other organs in the abdomen were also slightly low. In addition, the hepatic uptake of (99m)Tc-DMP-NGA was blocked by preinjecting free GSA as blocking agent. The result indicates that (99m)Tc-DMP-NGA has specific binding to ASGP receptor. Images acquired with Kodak In-Vivo Imaging System FX Pro showed significant difference before and after inhibition. The promising biological properties of (99m)Tc-DMP-NGA afford potential applications in liver receptor imaging for assessment of hepatocyte function.

  13. Identification of Staphylococcus aureus infection by aptamers directly radiolabeled with technetium-99m.

    PubMed

    dos Santos, Sara Roberta; Rodrigues Corrêa, Cristiane; Branco de Barros, André Luís; Serakides, Rogéria; Fernandes, Simone Odília; Cardoso, Valbert Nascimento; de Andrade, Antero Silva Ribeiro

    2015-03-01

    Aptamers are oligonucleotides that have high affinity and specificity for their molecular targets which are emerging as a new class of molecules for radiopharmaceuticals development. In this study, aptamers selected to Staphylococcus aureus were evaluated for bacterial infection identification. Anti S. aureus aptamers were labeled with (99m)Tc by the direct method. The radiolabel yield and complex stability were assessed by thin-layer chromatography (TLC). Three groups of Swiss mice containing 6 animals each were used. The first group was infected intramuscularly in the right thigh with S. aureus. The second group was infected in the same way with C. albicans and the third group was injected with zymosan to induce aseptic inflammation. After 24 h, radiolabeled aptamers (22.2 MBq) were injected by the tail vein. The mice were euthanized 4 h post injection and tissue sample activities measured in a gamma counter. The (99m)Tc labeled aptamers were stable in saline, plasma and cystein excess. Radiolabeled aptamers showed increased uptake in the kidneys for all groups indicating a main renal excretion, which is consistent with the hydrophilic nature and small size of aptamers. The radiopharmaceutical showed rapid blood clearance indicated by a reduced dose (% ID/g) in the blood. The biodistribution showed that aptamers were able to identify the infection foci caused by S. aureus displaying a target/non-target ratio of 4.0±0.5. This ratio for mice infected with C. albicans was 2.0±0.4 while for mice with aseptic inflammation was 1.2±0.2. Histology confirmed the presence of infection in groups 1 and 2, and inflammation in group 3. The biodistibution study demonstrated a statistically higher uptake in the S. aureus foci relative to inflammation and C. albicans infected areas. These results highlight the potential of aptamers labeled directly with (99m)Tc for bacterial infection diagnosis by scintigraphy. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Technetium-99m and rhenium-188 complexes with one and two pendant bisphosphonate groups for imaging arterial calcification.

    PubMed

    Bordoloi, Jayanta Kumar; Berry, David; Khan, Irfan Ullah; Sunassee, Kavitha; de Rosales, Rafael Torres Martin; Shanahan, Catherine; Blower, Philip J

    2015-03-21

    The first (99m)Tc and (188)Re complexes containing two pendant bisphosphonate groups have been synthesised, based on the mononuclear M(v) nitride core with two dithiocarbamate ligands each with a pendant bisphosphonate. The structural identity of the (99)Tc and stable rhenium analogues as uncharged, mononuclear nitridobis(dithiocarbamate) complexes was determined by electrospray mass spectrometry. The (99m)Tc complex showed greater affinity for synthetic and biological hydroxyapatite, and greater stability in biological media, than the well-known but poorly-characterised and inhomogeneous bone imaging agent (99m)Tc-MDP. It gave excellent SPECT images of both bone calcification (mice and rats) and vascular calcification (rat model), but the improved stability and the availability of two pendant bisphosphonate groups conferred no dramatic advantage in imaging over the conventional (99m)Tc-MDP agent in which the bisphosphonate group is bound directly to Tc. The (188)Re complex also showed preferential uptake in bone. These tracers and the biological model of vascular calcification offer the opportunity to study the biological interpretation and clinical potential of radionuclide imaging of vascular calcification and to deliver radionuclide therapy to bone metastases.

  15. A Pilot Study Measuring the Distribution and Permeability of a Vaginal HIV Microbicide Gel Vehicle Using Magnetic Resonance Imaging, Single Photon Emission Computed Tomography/Computed Tomography, and a Radiolabeled Small Molecule.

    PubMed

    Fuchs, Edward J; Schwartz, Jill L; Friend, David R; Coleman, Jenell S; Hendrix, Craig W

    2015-11-01

    Vaginal microbicide gels containing tenofovir have proven effective in HIV prevention, offering the advantage of reduced systemic toxicity. We studied the vaginal distribution and effect on mucosal permeability of a gel vehicle. Six premenopausal women were enrolled. In Phase 1, a spreading gel containing (99m)technetium-DTPA ((99m)Tc) radiolabel and gadolinium contrast for magnetic resonance imaging (MRI) was dosed intravaginally. MRI was obtained at 0.5, 4, and 24 h, and single photon emission computed tomography with conventional computed tomography (SPECT/CT) at 1.5, 5, and 25 h postdosing. Pads and tissues were measured for activity to determine gel loss. In Phase 2, nonoxynol-9 (N-9), containing (99m)Tc-DTPA, was dosed as a permeability control; permeability was measured in blood and urine for both phases. SPECT/CT showed the distribution of spreading gel throughout the vagina with the highest concentration of radiosignal in the fornices and ectocervix; signal intensity diminished over 25 h. MRI showed the greatest signal accumulation in the fornices, most notably 1-4 h postdosing. The median (interquartile range) isotope signal loss from the vagina through 6 h was 29.1% (15.8-39.9%). Mucosal permeability to (99m)Tc-DTPA following spreading gel was negligible, in contrast to N-9, with detectable radiosignal in plasma, peaking at 8 h (5-12). Following spreading gel dosing, 0.004% (0.001-2.04%) of the radiosignal accumulated in urine over 12 h compared to 8.31% (7.07-11.01%) with N-9, (p=0.043). Spreading gel distributed variably throughout the vagina, persisting for 24 h, with signal concentrating in the fornices and ectocervix. The spreading gel had no significant effect on vaginal mucosal permeability.

  16. Brain single photon emission computed tomography in neonates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Denays, R.; Van Pachterbeke, T.; Tondeur, M.

    1989-08-01

    This study was designed to rate the clinical value of ({sup 123}I)iodoamphetamine (IMP) or ({sup 99m}Tc) hexamethyl propylene amine oxyme (HM-PAO) brain single photon emission computed tomography (SPECT) in neonates, especially in those likely to develop cerebral palsy. The results showed that SPECT abnormalities were congruent in most cases with structural lesions demonstrated by ultrasonography. However, mild bilateral ventricular dilatation and bilateral subependymal porencephalic cysts diagnosed by ultrasound were not associated with an abnormal SPECT finding. In contrast, some cortical periventricular and sylvian lesions and all the parasagittal lesions well visualized in SPECT studies were not diagnosed by ultrasound scans.more » In neonates with subependymal and/or intraventricular hemorrhage the existence of a parenchymal abnormality was only diagnosed by SPECT. These results indicate that ({sup 123}I)IMP or ({sup 99m}Tc)HM-PAO brain SPECT shows a potential clinical value as the neurodevelopmental outcome is clearly related to the site, the extent, and the number of cerebral lesions. Long-term clinical follow-up is, however, mandatory in order to define which SPECT abnormality is associated with neurologic deficit.« less

  17. An estimate of the inventory of technetium-99 in the sub-tidal sediments of the Irish Sea.

    PubMed

    Jenkinson, Stuart B; McCubbin, David; Kennedy, Paul H W; Dewar, Alastair; Bonfield, Rachel; Leonard, Kinson S

    2014-07-01

    Published results from earlier studies have provided indications that measurable quantities of technetium-99 ((99)Tc) have accumulated in the sub-tidal sediments of the Irish Sea. This is due to the enhanced discharges from the Sellafield nuclear reprocessing plant in Cumbria, UK (between 1994 and 2004). Depth distributions of (99)Tc concentrations in sub-tidal sediments have been determined from a limited number of Irish Sea sites, following the collection of deep sediment cores (up to 2 m in depth), sampled in two research cruise surveys in 2005 and 2006. Vertical concentration profiles of (99)Tc from a range of substrates in the Irish Sea are presented here and these have been used to produce an estimate of the total inventory of (99)Tc residing in the sub-tidal sediments of the Irish Sea. Significant variation was observed between (99)Tc concentrations in the sediment samples, as well as in the shape of individual depth profiles. As anticipated, concentrations tended to be greater on fine-grained (muddy) substrates and showed a general decrease with distance from Sellafield. Vertical concentration profiles of (137)Cs, and (137)Cs data from published work, have also been considered to evaluate the use of the relatively few (99)Tc core data (upon which to determine the (99)Tc inventory). The inventories of (99)Tc and (137)Cs are estimated to have been of the order of 30 and 455 terabecquerels (TBq), respectively, or ∼2% of the total cumulative Sellafield discharge for each of the two radionuclides. The residence half-time of (137)Cs in the sub-tidal sediments of the Irish Sea is estimated to be in the order of ∼16 years. Therefore, as the Kd values for (99)Tc and (137)Cs are similar, this also provides an indicative value to predict future losses of (99)Tc from the sediment reservoir. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  18. LETTER TO THE EDITOR: Combined optical and single photon emission imaging: preliminary results

    NASA Astrophysics Data System (ADS)

    Boschi, Federico; Spinelli, Antonello E.; D'Ambrosio, Daniela; Calderan, Laura; Marengo, Mario; Sbarbati, Andrea

    2009-12-01

    In vivo optical imaging instruments are generally devoted to the acquisition of light coming from fluorescence or bioluminescence processes. Recently, an instrument was conceived with radioisotopic detection capabilities (Kodak in Vivo Multispectral System F) based on the conversion of x-rays from the phosphorus screen. The goal of this work is to demonstrate that an optical imager (IVIS 200, Xenogen Corp., Alameda, USA), designed for in vivo acquisitions of small animals in bioluminescent and fluorescent modalities, can even be employed to detect signals due to radioactive tracers. Our system is based on scintillator crystals for the conversion of high-energy rays and a collimator. No hardware modifications are required. Crystals alone permit the acquisition of photons coming from an in vivo 20 g nude mouse injected with a solution of methyl diphosphonate technetium 99 metastable (Tc99m-MDP). With scintillator crystals and collimators, a set of measurements aimed to fully characterize the system resolution was carried out. More precisely, system point spread function and modulation transfer function were measured at different source depths. Results show that system resolution is always better than 1.3 mm when the source depth is less than 10 mm. The resolution of the images obtained with radioactive tracers is comparable with the resolution achievable with dedicated techniques. Moreover, it is possible to detect both optical and nuclear tracers or bi-modal tracers with only one instrument.

  19. Two peptide receptor ligands (99m)Tc-EDDA/HYNIC-Tyr(3)-octreotide and (99m)Tc-EDDA/HYNIC-(D)Glu-octagastrin for scintigraphy of medullary thyroid carcinoma.

    PubMed

    Kosowicz, Jerzy; Mikołajczak, Renata; Czepczyński, Rafał; Ziemnicka, Katarzyna; Gryczyńska, Maria; Sowiński, Jerzy

    2007-10-01

    Somatostatin and gastrin receptors are overexpressed in medullary thyroid carcinoma (MTC) cells; hence, both of them are potential targets for peptide receptor scintigraphy and radiotherapy. Therefore, the aim of our study was to assess the clinical value of two technetium-99m-labeled peptides, a new gastrin analog, the EDDA/HYNIC-(D)Glu-octagastrin and a somatostatin analog, EDDA/HYNIC-Tyr(3)-octreotide (EDDA/HYNIC-TOC) for scintigraphy in patients with MTC to detect recurrences and metastases and select patients for peptide receptor radiotherapy. Thirty (30) patients, 20 females and 10 males, 22-83 years of age (mean, 52.7) with the diagnosis of MTC in different stages of the disease (preoperative, postsurgery, remission, recurrence, or metastatic disease) were included in this study. Before surgery, in all patients serum calcitonin concentrations were elevated. The diagnosis of MTC was confirmed in all cases by histopathology of the removed tumor and immunohistochemical staining giving positive reactions for calcitonin and chromogranin A. Imaging studies using (99m)Tc-EDDA/HYNIC-TOC and a new minigastrin analog, (99m)Tc-EDDA/HYNIC-(D)Glu-octagastrin, were performed in each patient and the results compared with each other and with other imaging methods. Scans of the whole body, head, neck, and chest were performed 2 and 4 hours after injections of the tracer, 500-600 MBq in each case, using a double-head Varicam (Elscint, Israel) gamma camera. (99m)Tc-EDDA/HYNIC-TOC detected somatostatin receptor-positive lesions in 20 patients with MTC, whereas (99m)Tc-EDDA/HYNIC-(D)Glu-octagastrin displayed gastrin receptors in 11 patients. In 9 cases, the scans were positive in both methods, although in 2 cases different pathologic foci were visualized. In 12 cases, only (99m)Tc-EDDA/HYNIC-TOC scintigraphy was positive, whereas in 3 other cases only (99m)Tc-EDDA/HYNIC-(D)Glu-octagastrin revealed pathologic lesions. Scintigraphy using (99m)Tc-HYNIC-TOC permits the visualization

  20. Review of Extraskeletal Activity on Tc-99m Methylene Diphosphonate Bone Scintigraphy and Value of Cross-Sectional and SPECT-CT Imaging Correlation.

    PubMed

    Bermo, Mohammed; Behnia, Sanaz; Fair, Joanna; Miyaoka, Robert S; Elojeimy, Saeed

    2017-07-31

    Recognizing the different mechanisms and imaging appearance of extraskeletal Tc-99m methylene diphosphonate uptake enhances the diagnostic value of bone scan interpretation. In this article, we present a pictorial review of the different mechanisms of extraskeletal Tc-99m methylene diphosphonate uptake on bone scintigraphy including neoplastic, inflammatory, ischemic, traumatic, excretory, and iatrogenic. We also illustrate through case examples the added value of correlation with cross-sectional and single photon emission computed tomography and computed tomography imaging in localizing and characterizing challenging cases of extraskeletal uptake. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Comparison of LVEF assessed by 2D echocardiography, gated blood pool SPECT, 99mTc tetrofosmin gated SPECT, and 18F-FDG gated PET with ERNV in patients with CAD and severe LV dysfunction.

    PubMed

    Raja, Senthil; Mittal, Bhagwant R; Santhosh, Sampath; Bhattacharya, Anish; Rohit, Manoj K

    2014-11-01

    Left ventricular ejection fraction (LVEF) is the single most important predictor of prognosis in patients with coronary artery disease (CAD) and left ventricular (LV) dysfunction. Equilibrium radionuclide ventriculography (ERNV) is considered the most reliable technique for assessing LVEF. Most of these patients undergo two dimensional (2D) echocardiography and myocardial viability study using gated myocardial perfusion imaging (MPI) or gated F-fluorodeoxyglucose (F-FDG) PET. However, the accuracy of LVEF assessed by these methods is not clear. This study has been designed to assess the correlation and agreement between the LVEF measured by 2D echocardiography, gated blood pool single photon emission computed tomography (SPECT), Tc tetrofosmin gated SPECT, and F-FDG gated PET with ERNV in CAD patients with severe LV dysfunction. Patients with CAD and severe LV dysfunction [ejection fraction (EF) <35 assessed by 2D echocardiography] were prospectively included in the study. These patients underwent ERNV along with gated blood pool SPECT, Tc tetrofosmin gated SPECT, and F-FDG gated PET as per the standard protocol for myocardial viability assessment and LVEF calculation. Spearman's coefficient of correlation (r) was calculated for the different sets of values with significance level kept at a P-value less than 0.05. Bland-Altman plots were inspected to visually assess the between-agreement measurements from different methods. Forty-one patients were prospectively included. LVEF calculated by various radionuclide methods showed good correlation with ERNV as follows: gated blood pool SPECT, r=0.92; MPI gated SPECT, r=0.85; and F-FDG gated PET, r=0.76. However, the correlation between 2D echocardiography and ERNV was poor (r=0.520). The Bland-Altman plot for LVEF measured by all radionuclide methods showed good agreement with ERNV. However, agreement between 2D echocardiography and ERNV is poor, as most of the values in this plot gave a negative difference for low EF

  2. Method for generating a crystalline {sup 99}MoO{sub 3} product and the isolation {sup 99m}Tc compositions therefrom

    DOEpatents

    Bennett, R.G.; Christian, J.D.; Kirkham, R.J.; Tranter, T.J.

    1998-09-01

    An improved method is described for producing {sup 99m}Tc compositions. {sup 100}Mo metal is irradiated with photons in a particle (electron) accelerator to produce {sup 99}Mo metal which is dissolved in a solvent. A solvated {sup 99}Mo product is then dried to generate a supply of {sup 99}MoO{sub 3} crystals. The crystals are thereafter heated at a temperature which will sublimate the crystals and form a gaseous mixture containing vaporized {sup 99m}TcO{sub 3} and vaporized {sup 99m}TcO{sub 2} but will not cause the production of vaporized {sup 99}MoO{sub 3}. The mixture is then combined with an oxidizing gas to generate a gaseous stream containing vaporized {sup 99m}Tc{sub 2}O{sub 7}. Next, the gaseous stream is cooled to a temperature sufficient to convert the vaporized {sup 99m}Tc{sub 2}O{sub 7} into a condensed {sup 99m}Tc-containing product. The product has high purity levels resulting from the use of reduced temperature conditions and ultrafine crystalline {sup 99}MoO{sub 3} starting materials with segregated {sup 99m}Tc compositions therein which avoid the production of vaporized {sup 99}MoO{sub 3} contaminants. 1 fig.

  3. Method for generating a crystalline .sup.99 MoO.sub.3 product and the isolation .sup.99m Tc compositions therefrom

    DOEpatents

    Bennett, Ralph G.; Christian, Jerry D.; Kirkham, Robert J.; Tranter, Troy J.

    1998-01-01

    An improved method for producing .sup.99m Tc compositions. .sup.100 Mo metal is irradiated with photons in a particle (electron) accelerator to produce .sup.99 Mo metal which is dissolved in a solvent. A solvated .sup.99 Mo product is then dried to generate a supply of .sup.99 MoO.sub.3 crystals. The crystals are thereafter heated at a temperature which will sublimate the crystals and form a gaseous mixture containing vaporized .sup.99m TcO.sub.3 and vaporized .sup.99m TcO.sub.2 but will not cause the production of vaporized .sup.99 MoO.sub.3. The mixture is then combined with an oxidizing gas to generate a gaseous stream containing vaporized .sup.99m Tc.sub.2 O.sub.7. Next, the gaseous stream is cooled to a temperature sufficient to convert the vaporized .sup.99m Tc.sub.2 O.sub.7 into a condensed .sup.99m Tc-containing product. The product has high purity levels resulting from the use of reduced temperature conditions and ultrafine crystalline .sup.99 MoO.sub.3 starting materials with segregated .sup.99m Tc compositions therein which avoid the production of vaporized .sup.99 MoO.sub.3 contaminants.

  4. Bone marrow uptake of 99mTc-MIBI in patients with multiple myeloma.

    PubMed

    Fonti, R; Del Vecchio, S; Zannetti, A; De Renzo, A; Di Gennaro, F; Catalano, L; Califano, C; Pace, L; Rotoli, B; Salvatore, M

    2001-02-01

    In a previous study, we showed the ability of technetium-99m methoxyisobutylisonitrile (99mTc-MIBI) scan to identify active disease in patients with multiple myeloma (Eur J Nucl Med 1998; 25: 714-720). In particular, a semiquantitative score of the extension and intensity of bone marrow uptake was derived and correlated with both the clinical status of the disease and plasma cell bone marrow infiltration. In order to estimate quantitatively 99mTc-MIBI bone marrow uptake and to verify the intracellular localization of the tracer, bone marrow samples obtained from 24 multiple myeloma patients, three patients with monoclonal gammopathy of undetermined significance (MGUS) and two healthy donors were studied for in vitro uptake. After centrifugation over Ficoll-Hypaque gradient, cell suspensions were incubated with 99mTc-MIBI and the uptake was expressed as the percentage of radioactivity specifically retained within the cells. The cellular localization of the tracer was assessed by micro-autoradiography. Twenty-two out of 27 patients underwent 99mTc-MIBI scan within a week of bone marrow sampling. Whole-body images were obtained 10 min after intravenous injection of 555 MBq of the tracer; the extension and intensity of 99mTc-MIBI uptake were graded using the semiquantitative score. A statistically significant correlation was found between in vitro uptake of 99mTc-MIBI and both plasma cell infiltration (Pearson's coefficient of correlation r=0.69, P<0.0001) and in vivo score (Spearman rank correlation coefficient r=0.60, P<0.01). No specific tracer uptake was found in bone marrow samples obtained from the two healthy donors. Micro-autoradiography showed localization of 99mTc-MIBI inside the plasma cells infiltrating the bone marrow. Therefore, our findings show that the degree of tracer uptake both in vitro and in vivo is related to the percentage of infiltrating plasma cells which accumulate the tracer in their inner compartments.

  5. Single-photon and two-photon excited fluorescence behavior of a novel fluorene-based compound

    NASA Astrophysics Data System (ADS)

    Ma, Wenbo; Wu, Yiquan; Gu, Donghong; Gan, Fuxi

    2005-09-01

    A D-π-D type compound, 2,7-bis(4-methoxystyryl)-9,9-bis(2-ethylhexyl)-9H-fluorene (abbreviated as MO-Flu-MO), where electron-donor D is methoxy group andπis fluorene unit, has been synthesized. The molecular structures of the compound were characterized by elemental analyses, EI-MS and FT-IR spectra. UV-Vis spectra in the region 230--1000 nm and single-photon excited fluorescence in tetrahydrofuran (THF) of the compound were measured. It is found that the new compound exhibits strong two-photon excited fluorescence in the region 380--500 nm and moderate two-photon absorption (TPA) value in the femtoseconds regime (TPA cross-section as high as 55×10-50 cm4 s photon-1 with 13fs laser pulses). The results demonstrate that the compound is a promising candidate for two-photon three-dimensional (3D) optical data storage.

  6. A (99m) Tc-tricine-HYNIC-labeled peptide targeting the neurotensin receptor for single-photon imaging in malignant tumors.

    PubMed

    Erfani, Mostafa; Zarrabi Ahrabi, Nakisa; Shafiei, Mohammad; Shirmardi, Seyed Pezhman

    2014-03-01

    In this study, a new neurotensin (NT) analog was labeled with (99m) Tc via HYNIC chelator and tricine as coligand and investigated further. An NT (7-13) analog was prepared, and labeling with (99m) Tc was performed. The internalization rate and biodistribution of radiopeptide were studied in HT-29 cells and nude mice bearing tumor, respectively. Radiolabeling with (99m) Tc was performed at high specific activities (54 MBq/nmol) with an acceptable labeling yield (>95%). In vitro cell line studies showed a specific internalization uptake up to 13.23 ± 0.45% during 4 h which was blocked in the presence of excess cold peptide to 0.83 ± 0.15%. In biodistribution studies, uptake was observed in NT receptor-positive organs so that after 1 h the uptakes in mouse intestine and tumor were 1.23 ± 0.16% ID/g and 1.12 ± 0.11% ID/g, respectively. In animals co-injected with excess cold peptide, reduction uptake in tumor and intestines were 73% (1.10% vs. 0.29% ID/g at 4 h) and 61% (1.22% vs. 0.47% ID/g at 4 h) respectively. Predominant renal excretion pathway with a highest accumulation of activity in bladder was observed for this radiopeptide. This radiolabeled peptide could be a candidate for detection of NT positive tumors. Copyright © 2014 John Wiley & Sons, Ltd.

  7. The utility of 99mTc-EDDA/HYNIC-TOC scintigraphy for assessment of lung lesions in patients with neuroendocrine tumors.

    PubMed

    Pavlovic, S; Artiko, V; Sobic-Saranovic, D; Damjanovic, S; Popovic, B; Jakovic, R; Petrasinovic, Z; Jaksic, E; Todorovic-Tirnanic, M; Saranovic, D; Micev, M; Novosel, S; Nikolic, N; Obradovic, V

    2010-01-01

    Our aim was to assess clinical utility of 99mTc-EDDA/HYNIC-TOC scintigraphy for evaluation of lung lesions in patients with neuroendocrine tumors (NETs). Single photon emission computed tomography (SPECT) of the thorax and whole body scintigraphy were performed in 34 patients using 99mTc-EDDA/HYNIC-TOC. Visual assessment was complemented by semiquantitative evaluation based on tumor to non-tumor (T/NT) ratio. Clinical, laboratory, and histological findings served as the standard for comparison. Enhanced tracer uptake was observed on both SPECT and whole body scintigraphy in 29 of 34 patients (88% sensitivity). T/NT ratios were significantly higher on SPECT than whole body images (2.96+/-1.07 vs.1.70+/-0.43, p 99mTc-EDDA/Hynic-TOC, lung involvement of NETs, T/NT ratio.

  8. Studies on focal alveolar bone healing with technetium (Tc)-99m labeled methylene diphosphonate and gold-collimated cadmium telluride probe

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsuchimochi, M.; Hosain, F.; Engelke, W.

    1991-01-01

    The benefit of using a collimator for a miniaturized cadmium telluride probe was evaluated by monitoring the bone-healing processes for 13 weeks after the induction of small iatrogenic alveolar bone lesions in one side of the mandible in beagles. Technetium (Tc)-99m labeled methylene diphosphonate (200 to 300 MBq, 5.1 to 8.1 mCi, in a solution of 0.5 to 1 ml, intravenously) was used as a bone-seeking radiopharmaceutical. The radioactivity over the bone lesion (L) and the contralateral normal site (C) in the mandible were measured between 1.5 and 2 hours after injection of the tracer, and the activity ratio L/Cmore » served as an index of relative bone uptake. A study of six dogs revealed that the healing response to a hemispheric bone defect of 2 mm diameter in the cortical bone could not be detected by an uncollimated probe, and in a repeated study in two dogs the use of a gold collimator (5 mm in diameter, 5 mm in length) did not increase the L/C ratio significantly. A second study in six dogs with 5 mm lesions showed that although systematic trends in the time courses of the L/C ratio obtained both with and without the collimator could be demonstrated, the L/C ratio of collimated versus uncollimated measurements was significantly (p less than 0.005) increased. In three of the latter six dogs, abscesses developed after 9 weeks, leading to a second increase (p less than 0.05) of the L/C ratio with collimation compared with the noninflammation group; without collimation no significant (p greater than 0.15) difference between the two groups could be demonstrated.« less

  9. A Rare Case of Suprahepatic Gall Bladder with Phocomelia and Pancytopenia: Detected by Tc-99m Mebrofenin Scintigraphy

    PubMed Central

    Rather, Tanveeer Ah; Khan, Shoukat H.; Singh, Manjeet; Choh, Naseer A.

    2013-01-01

    The possibility of an ectopic gallbladder should always be considered whenever there is a failure to localize it in its normal anatomical position on routine imaging. Although a very rare entity, the anomalous position of gallbladder can result in misinterpretation of imaging findings and create clinical confusion. Awareness of such an anomaly facilitates proper diagnosis and subsequent management. The authors report a very rare case of suprahepatic gallbladder associated with phocomelia, pancytopenia, and splenomegaly in a young 25-year-old female. The suprahepatic gallbladder was initially visualized on Technetium-99m (Tc-99m) Mebrofenin radionuclide hepatobiliary scintigraphy. Subsequent magnetic resonance cholecystopancreatography (MRCP) was also done to confirm the diagnosis. PMID:23961256

  10. Radiolabeling of VEGF165 with 99mTc to evaluate VEGFR expression in tumor angiogenesis.

    PubMed

    Galli, Filippo; Artico, Marco; Taurone, Samanta; Manni, Isabella; Bianchi, Enrica; Piaggio, Giulia; Weintraub, Bruce D; Szkudlinski, Mariusz W; Agostinelli, Enzo; Dierckx, Rudi A J O; Signore, Alberto

    2017-06-01

    Angiogenesis is the main process responsible for tumor growth and metastatization. The principal effector of such mechanism is the vascular endothelial growth factor (VEGF) secreted by cancer cells and other components of tumor microenvironment. Radiolabeled VEGF analogues may provide a useful tool to noninvasively image tumor lesions and evaluate the efficacy of anti-angiogenic drugs that block the VEGFR pathway. Aim of the present study was to radiolabel the human VEGF165 analogue with 99mTechnetium (99mTc) and to evaluate the expression of VEGFR in both cancer and endothelial cells in the tumor microenvironment. 99mTc-VEGF showed in vitro binding to HUVEC cells and in vivo to xenograft tumors in mice (ARO, K1 and HT29). By comparing in vivo data with immunohistochemical analysis of excised tumors we found an inverse correlation between 99mTc-VEGF165 uptake and VEGF histologically detected, but a positive correlation with VEGF receptor expression (VEGFR1). Results of our studies indicate that endogenous VEGF production by cancer cells and other cells of tumor microenvironment should be taken in consideration when performing scintigraphy with radiolabeled VEGF, because of possible false negative results due to saturation of VEGFRs.

  11. Molybdenum target specifications for cyclotron production of 99mTc based on patient dose estimates.

    PubMed

    Hou, X; Tanguay, J; Buckley, K; Schaffer, P; Bénard, F; Ruth, T J; Celler, A

    2016-01-21

    In response to the recognized fragility of reactor-produced (99)Mo supply, direct production of (99m)Tc via (100)Mo(p,2n)(99m)Tc reaction using medical cyclotrons has been investigated. However, due to the existence of other Molybdenum (Mo) isotopes in the target, in parallel with (99m)Tc, other technetium (Tc) radioactive isotopes (impurities) will be produced. They will be incorporated into the labeled radiopharmaceuticals and result in increased patient dose. The isotopic composition of the target and beam energy are main factors that determine production of impurities, thus also dose increases. Therefore, they both must be considered when selecting targets for clinical (99m)Tc production. Although for any given Mo target, the patient dose can be predicted based on complicated calculations of production yields for each Tc radioisotope, it would be very difficult to reverse these calculations to specify target composition based on dosimetry considerations. In this article, a relationship between patient dosimetry and Mo target composition is studied. A simple and easy algorithm for dose estimation, based solely on the knowledge of target composition and beam energy, is described. Using this algorithm, the patient dose increase due to every Mo isotope that could be present in the target is estimated. Most importantly, a technique to determine Mo target composition thresholds that would meet any given dosimetry requirement is proposed.

  12. Molybdenum target specifications for cyclotron production of 99mTc based on patient dose estimates

    NASA Astrophysics Data System (ADS)

    Hou, X.; Tanguay, J.; Buckley, K.; Schaffer, P.; Bénard, F.; Ruth, T. J.; Celler, A.

    2016-01-01

    In response to the recognized fragility of reactor-produced 99Mo supply, direct production of 99mTc via 100Mo(p,2n)99mTc reaction using medical cyclotrons has been investigated. However, due to the existence of other Molybdenum (Mo) isotopes in the target, in parallel with 99mTc, other technetium (Tc) radioactive isotopes (impurities) will be produced. They will be incorporated into the labeled radiopharmaceuticals and result in increased patient dose. The isotopic composition of the target and beam energy are main factors that determine production of impurities, thus also dose increases. Therefore, they both must be considered when selecting targets for clinical 99mTc production. Although for any given Mo target, the patient dose can be predicted based on complicated calculations of production yields for each Tc radioisotope, it would be very difficult to reverse these calculations to specify target composition based on dosimetry considerations. In this article, a relationship between patient dosimetry and Mo target composition is studied. A simple and easy algorithm for dose estimation, based solely on the knowledge of target composition and beam energy, is described. Using this algorithm, the patient dose increase due to every Mo isotope that could be present in the target is estimated. Most importantly, a technique to determine Mo target composition thresholds that would meet any given dosimetry requirement is proposed.

  13. Efficacy of (99m)Tc-EDDA/HYNIC-TOC SPECT/CT scintigraphy in Graves' ophthalmopathy.

    PubMed

    Zhao, Rong; Wang, Jiang; Deng, Jinglan; Yang, Weidong; Wang, Jing

    2012-01-01

    The aim of this study was to investigate the predictive role of the orbital somatostatin receptor scintigraphy with (99m)Tc-EDDA/HYNIC-TOC ((99m)Tc-TOC) to detect clinical stage of Graves' ophthalmopathy and the response to corticosteroid therapy. The subjects of the experiment were 46 patients with Graves' ophthalmopathy (GO) and four volunteers without eye disease or GO as the normal group (NG). Single photon emission computed tomography (SPECT), computed tomography (CT) and the left and right lateral position planar imaging of the heads of the all subjects were obtained 4 h after the intravenous injection of 555 MBq of (99m)Tc-TOC. The (99m)Tc-TOC SPECT/CT was repeated 3 months later. 35 (35/46) patients were received corticosteroid therapy (prednisolone, 10 mg po tid ) for 3 months, however, the other 11 patients as control groups did not receive any treatment. The treatment effect was evaluated both by the orbital (99m)Tc-TOC uptake and NOSPECS. A significant decrease in the O/OC ratio was observed in 22 GO patients between pre- and post-treatment (1.64 ± 0.13 vs. 1.21 ± 0.09, P < 0.05). There were neither significant difference of the O/OC ratio in 13 GO patients between pre- and post-treatment periods, nor significant difference in the 9 (9/11) patients before and after three months. Orbital (99m)Tc-TOC scintigraphy is a feasible technique to estimate the Graves' ophthalmopathy activity and predict the response to subsequent corticosteroid therapy in GO patients. The technique could be a useful tool for physicians not familiar with CAS determination.

  14. Efficacy of 99mTc-EDDA/HYNIC-TOC SPECT/CT scintigraphy in Graves’ ophthalmopathy

    PubMed Central

    Zhao, Rong; Wang, Jiang; Deng, Jinglan; Yang, Weidong; Wang, Jing

    2012-01-01

    The aim of this study was to investigate the predictive role of the orbital somatostatin receptor scintigraphy with 99mTc-EDDA/HYNIC-TOC (99mTc-TOC) to detect clinical stage of Graves’ ophthalmopathy and the response to corticosteroid therapy. The subjects of the experiment were 46 patients with Graves’ ophthalmopathy (GO) and four volunteers without eye disease or GO as the normal group (NG). Single photon emission computed tomography (SPECT), computed tomography (CT) and the left and right lateral position planar imaging of the heads of the all subjects were obtained 4 h after the intravenous injection of 555 MBq of 99mTc-TOC. The 99mTc-TOC SPECT/CT was repeated 3 months later. 35 (35/46) patients were received corticosteroid therapy (prednisolone, 10 mg po tid ) for 3 months, however, the other 11 patients as control groups did not receive any treatment. The treatment effect was evaluated both by the orbital 99mTc-TOC uptake and NOSPECS. A significant decrease in the O/OC ratio was observed in 22 GO patients between pre- and post-treatment (1.64 ± 0.13 vs. 1.21 ± 0.09, P < 0.05). There were neither significant difference of the O/OC ratio in 13 GO patients between pre- and post-treatment periods, nor significant difference in the 9 (9/11) patients before and after three months. Orbital 99mTc-TOC scintigraphy is a feasible technique to estimate the Graves’ ophthalmopathy activity and predict the response to subsequent corticosteroid therapy in GO patients. The technique could be a useful tool for physicians not familiar with CAS determination. PMID:23133815

  15. THE RESULTS OF PARATHYROID HORMONE ASSAY IN PARATHYROID ASPIRATES IN PRE-OPERATIVE LOCALIZATION OF PARATHYROID ADENOMAS FOR FOCUSED PARATHYROIDECTOMY IN PATIENTS WITH NEGATIVE OR SUSPICIOUS TECHNETIUM-99M-SESTAMIBI SCANS.

    PubMed

    Ozderya, Aysenur; Temizkan, Sule; Cetin, Kenan; Ozugur, Sule; Gul, Aylin Ege; Aydin, Kadriye

    2017-09-01

    This study aimed to evaluate the results of parathyroid hormone (PTH) assay in parathyroid aspirates to determine uniglandular disease by an endocrinologist-performed ultrasound (US) in patients with discordant or negative technetium-sestamibi scans and to evaluate whether this procedure increases the number of focused parathyroidectomies (FPs). We analyzed the data of 65 patients who underwent an endocrinologist-performed US-guided parathyroid fine-needle aspiration (FNA) with PTH wash-out, retrospectively. The results of PTH wash-out procedure and the reports of parathyroid surgery and pathology were reviewed. Of 65 patients, 54 had positive PTH wash-out results. The median serum PTH level of patients with positive and negative PTH wash-out results was 143 (25 and 75% interquartile range [IQR], 114 to 197) versus 154 (IQR, 115 to 255) pg/mL (P = .45), and the median PTH in FNA was 3,533 (IQR, 1,481 to 3,534) versus 6.0 (IQR, 1 to 6) pg/mL (P<.001), respectively. Forty-five patients underwent surgery. Of the operated patients, 42 had positive PTH wash-out results and had successful FP. Four patients with redo surgery had positive PTH wash-out results and were successfully re-operated with FP. Of 11 patients with negative PTH wash-out results, 3 had bilateral neck exploration (BNE) surgery and 2 patients were successfully operated, while surgery was unsuccessful in 1 patient, despite BNE. Our study results suggest that endocrinologist-performed US and parathyroid FNA with PTH wash-out increases the number and success of FPs. In particular, patients with redo surgery may benefit from this procedure. 4D-CT = four-dimensional computed tomography BNE = bilateral neck exploration FNA = fine-needle aspiration FNAB = fine-needle aspiration biopsy FP = focused parathyroidectomy IQR = 25 and 75% inter-quartile range PHPT = primary hyperparathyroidism PPV = positive predictive value PTH = parathyroid hormone 99m Tc = technetium US = ultrasound.

  16. Single photon sources with single semiconductor quantum dots

    NASA Astrophysics Data System (ADS)

    Shan, Guang-Cun; Yin, Zhang-Qi; Shek, Chan Hung; Huang, Wei

    2014-04-01

    In this contribution, we briefly recall the basic concepts of quantum optics and properties of semiconductor quantum dot (QD) which are necessary to the understanding of the physics of single-photon generation with single QDs. Firstly, we address the theory of quantum emitter-cavity system, the fluorescence and optical properties of semiconductor QDs, and the photon statistics as well as optical properties of the QDs. We then review the localization of single semiconductor QDs in quantum confined optical microcavity systems to achieve their overall optical properties and performances in terms of strong coupling regime, efficiency, directionality, and polarization control. Furthermore, we will discuss the recent progress on the fabrication of single photon sources, and various approaches for embedding single QDs into microcavities or photonic crystal nanocavities and show how to extend the wavelength range. We focus in particular on new generations of electrically driven QD single photon source leading to high repetition rates, strong coupling regime, and high collection efficiencies at elevated temperature operation. Besides, new developments of room temperature single photon emission in the strong coupling regime are reviewed. The generation of indistinguishable photons and remaining challenges for practical single-photon sources are also discussed.

  17. The Evaluation of Novel Tin Materials for the Removal of Technetium from Groundwater

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parker, Kent E.; Wellman, Dawn M.

    2017-06-30

    Technetium-99 ( 99Tc) is present at several U.S. Department of Energy (DOE) facilities, including the Hanford, Oak Ridge, Paducah, Portsmouth, and Savannah River sites. Due to its mobility, persistence, and toxicity in the environment, developing means to immobilize and/or remove technetium from the environment is currently a top priority for DOE. However, there are currently very few approaches that effectively manage the risks of technetium to human health and the environment. The objective of this study is to evaluate novel synthetic materials that could enable direct removal of technetium from groundwater. The following report •assesses the viability of existing methodologiesmore » for synthesis of tin (II) apatite for in situ formation and remediation of 99Tc within the subsurface environment •discusses the development of alternative methodologies for production of tin (II) apatite •evaluates nanoporous tin phosphate materials for removal of technetium from groundwater.« less

  18. Technetium-99 conjugated with methylene diphosphonate ameliorates ovariectomy-induced osteoporotic phenotype without causing osteonecrosis in the jaw.

    PubMed

    Zhao, Yinghua; Wang, Lei; Liu, Yi; Akiyama, Kentaro; Chen, Chider; Atsuta, Ikiru; Zhou, Tao; Duan, Xiaohong; Jin, Yan; Shi, Songtao

    2012-12-01

    Technetium-99 conjugated with methylene diphosphonate ((99)Tc-MDP) is a novel bisphosphonate derivative without radioactivity and has been successfully used to treat arthritis in China for years. Since bisphosphonate therapy has the potential to induce bisphosphonate-related osteonecrosis of the jaw (BRONJ), we examined whether (99)Tc-MDP represents a new class of bisphosphonate for antiresorptive therapy to ameliorate estrogen deficiency-induced bone resorption with less risk of causing BRONJ. We showed that (99)Tc-MDP-treated, ovariectomized (OVX) mice had significantly improved bone mineral density and trabecular bone volume in comparison to the untreated OVX group by inhibiting osteoclasts and enhancing osteogenic differentiation of bone marrow mesenchymal stem cells. To determine the potential of inducing BRONJ, (99)Tc-MDP/dexamethasone (Dex) or zoledronate/Dex was administered into C57BL/6J mice via the tail vein, followed by extraction of maxillary first molars. Interestingly, (99)Tc-MDP treatment showed less risk to induce osteonecrosis in the maxillary bones compared to zoledronate treatment group, partially because (99)Tc-MDP neither suppressed adaptive regulatory T cells nor activated the inflammatory T-helper-producing interleukin-17 cells. Taken together, our findings demonstrate that (99)Tc-MDP therapy may be a promising approach in the treatment of osteoporosis with less risk of causing BRONJ.

  19. Water-stable fac-{TcO₃}⁺ complexes - a new field of technetium chemistry.

    PubMed

    Braband, Henrik

    2011-01-01

    The development of technetium chemistry has been lagging behind that of its heavier congener rhenium, primarily because the inherent radioactivity of all Tc isotopes has limited the number of laboratories that can study the chemistry of this fascinating element. Although technetium is an artificial element, it is not rare. Significant amounts of the isotope (99)Tc are produced every day as a fission byproduct in nuclear power plants. Therefore, a fundamental understanding of the chemistry of (99)Tc is essential to avoid its release into the environment. In this article the chemistry of technetium at its highest oxidation state (+VII) is reviewed with a special focus on recent developments which make water-stable complexes of the general type [TcO(3)(tacn-R)](+) (tacn-R = 1,4,7-triazacyclononane or derivatives) accessible. Complexes containing the fac-{TcO(3)}(+) core display a unique reactivity. In analogy to [OsO(4)] and [RuO(4)], complexes containing the fac-{TcO(3)}(+) core undergo with alkenes metal-mediated, vicinal cis-dihydroxylation reactions (alkene-glycol interconversion) in water via a (3+2)-cycloaddition reaction. Therefore, water-stable fac-{(99m)TcO(3)}(+) complexes pave the way for a new labeling strategy for radiopharmaceutical applications, based on (3+2)-cycloaddition reactions. This new concept for the labeling of biomolecules with small [(99m)TcO(3)(tacn-R)](+)-type complexes by way of a (3+2)-cycloaddition with alkenes is discussed in detail. The herein reported developments in high-valent technetium chemistry create a new field of research with this artificial element. This demonstrates the potential of fundamental research to provide new impetus of innovation for the development of new methods for radiopharmaceutical applications.

  20. Radiolabelling of glycosylated MFE-23::CPG2 fusion protein (MFECP1) with 99mTc for quantitation of tumour antibody-enzyme localisation in antibody-directed enzyme pro-drug therapy (ADEPT).

    PubMed

    Francis, R J; Mather, S J; Chester, K; Sharma, S K; Bhatia, J; Pedley, R B; Waibel, R; Green, A J; Begent, R H J

    2004-08-01

    MFECP1 is a glycosylated recombinant fusion protein composed of MFE-23, a high-affinity anti-carcinoembryonic antigen (CEA) single chain Fv (scFv), fused to the enzyme carboxypeptidase G2 (CPG2), and has been constructed for use in antibody-directed enzyme pro-drug therapy (ADEPT). Radiolabelling of glycosylated MFECP1 with technetium-99m was developed for the purpose of determining tumour localisation of MFECP1 in a phase I ADEPT clinical study. The method used was 99mTc-carbonyl [99mTc(H2O)3(CO)3]+ (abbreviated to TcCO) mediated labelling of 99mTc to the hexahistidine (His) tag of MFECP1. MFECP1 fusion protein was labelled with TcCO under a variety of conditions, and this was shown to be a relatively simple and robust method. Tissue biodistribution was assessed in a CEA-expressing LS174T (human colon carcinoma) nude mouse xenograft model. Tissues were taken at 1, 4 and 6 h for assessment of distribution of radioactivity and for measurement of CPG2 enzyme levels. The amount of radioactivity retained by the tumour proved to be an accurate estimation of actual measured enzyme activity, indicating that this radiolabelling method does not appear to damage the antibody-antigen binding or the enzyme activity of MFECP1. However, correlation between CPG2 enzyme activity and measured radioactivity in liver, spleen and kidney was poor, indicating retention of radioactivity in non-tumour sites but loss of enzyme activity. The high retention of technetium radioisotope in normal tissues may limit the clinical applicability of this radiolabelling method for MFECP1; however, these results suggest that this technique does have applicability for measuring the biodistribution of His-tagged recombinant proteins.

  1. Comparison of personnel radiation dosimetry from myocardial perfusion scintigraphy: Technetium-99m-sestamibi versus thallium-201

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Culver, C.M.; Dworkin, H.J.

    1993-07-01

    The whole-body and hand radiation doses to our technical staff were retrospectively compared for three distinct 4-mo periods when either 201TI or 99mTc-sestamibi were exclusively used for stress myocardial perfusion imaging. During the initial 4-mo period when 99mTc-sestamibi replaced 201TI, the mean whole-body film badge readings increased from 100 to 450 microSv/mo (p < 0.001) for nuclear medicine technologists (n = 10) and from 240 to 560 microSv/mo (p < 0.05) for radiopharmacy technologists (n = 2). Mean TLD readings to the hands also increased, although the differences were not statistically significant for the nuclear medicine technologists. Noninvasive cardiology staffmore » were monitored with film badges and the mean whole-body film badge reading, when 99mTc-sestamibi was the imaging agent, was 360 microSv per month. Radiation reduction methods that decreased radiation exposure to staff were utilized. The most effective included the use of a lead face shield and lead lined storage container in the noninvasive imaging area, handling spills by shielding instead of decontamination and methods to reduce time spent in close proximity to the patient.« less

  2. Diagnosis of pyogenic pelvic inflammatory diseases by 99mTc-HMPAO leucocyte scintigraphy.

    PubMed

    Rachinsky, I; Boguslavsky, L; Goldstein, D; Golan, H; Pak, I; Katz, M; Lantsberg, S

    2000-12-01

    Pelvic inflammatory disease (PID) is one of the major health problems of women of child-bearing age. Among the most serious complications of PID is the formation of a tubo-ovarian abscess (TOA). Early diagnosis of this condition may prevent serious surgical complications such as peritonitis and sepsis, which may be fatal. The purpose of this study was to investigate the efficacy of technetium-99m hexamethylpropylene amine oxime (HMPAO) leucocyte scintigraphy in the diagnosis of TOA. Twenty women with high clinical suspicion of TOA underwent 99mTc-HMPAO leucocyte scintigraphy. The labelling of leucocytes with 99mTc-HMPAO was performed according to a standard protocol. Scans were obtained at 1, 3 and 24 h following the injection of the labelled leucocytes. In eight cases the early and/or late scan was positive, in 11 cases it was negative, and in one case of ovarian cyst torsion, confirmed by laparoscopy, it showed slight uptake in the capsule of the cyst (false-positive). The sensitivity of 99mTc-HMPAO leucocyte scintigraphy was 100%, specificity 91.6%, positive predictive value 89%, negative predictive value 100% and overall accuracy 95%. It is concluded that leucocyte scintigraphy is a non-invasive, safe, physiological and accurate procedure for the diagnosis of TOA. The 24-h scan is crucial, since in some cases the abscess was not clearly visualized on the early scan. Leucocyte scintigraphy may reduce the need for CT, diagnostic laparoscopy and unnecessary invasive surgical procedures.

  3. Early Dose Response to Yttrium-90 Microsphere Treatment of Metastatic Liver Cancer by a Patient-Specific Method Using Single Photon Emission Computed Tomography and Positron Emission Tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Campbell, Janice M.; Department of Radiation Oncology, Wayne State University, Detroit, MI; Wong, C. Oliver

    2009-05-01

    Purpose: To evaluate a patient-specific single photon emission computed tomography (SPECT)-based method of dose calculation for treatment planning of yttrium-90 ({sup 90}Y) microsphere selective internal radiotherapy (SIRT). Methods and Materials: Fourteen consecutive {sup 90}Y SIRTs for colorectal liver metastasis were retrospectively analyzed. Absorbed dose to tumor and normal liver tissue was calculated by partition methods with two different tumor/normal liver vascularity ratios: an average 3:1 and a patient-specific ratio derived from pretreatment technetium-99m macroaggregated albumin SPECT. Tumor response was quantitatively evaluated from fluorine-18 fluoro-2-deoxy-D-glucose positron emission tomography scans. Results: Positron emission tomography showed a significant decrease in total tumor standardizedmore » uptake value (average, 52%). There was a significant difference in the tumor absorbed dose between the average and specific methods (p = 0.009). Response vs. dose curves fit by linear and linear-quadratic modeling showed similar results. Linear fit r values increased for all tumor response parameters with the specific method (+0.20 for mean standardized uptake value). Conclusion: Tumor dose calculated with the patient-specific method was more predictive of response in liver-directed {sup 90}Y SIRT.« less

  4. An efficient HPLC method for the analysis of isomeric purity of technetium-99m-exametazime and identity confirmation using LC-MS.

    PubMed

    Vanderghinste, D; Van Eeckhoudt, M; Terwinghe, C; Mortelmans, L; Bormans, G M; Verbruggen, A M; Vanbilloen, H P

    2003-08-08

    99mTc-exametazime (99mTc-d,l-HMPAO, 99mTc-d,l-hexamethylpropyleneamine oxime) is a neutral rather unstable complex of short-lived 99mTc (t(1/2)=6 h) with the d,l-isomer (mixture of D,D- and L,L-isomers) of a bis-amine bis-oxime tetraligand. It is widely used for measurement of regional cerebral perfusion in nuclear medicine. The meso-isomer (D,L-form) should not be present in a preparation as it is not retained in brain and thus does not provide clinically useful information. Meso-HMPAO is removed from the ligand during the synthesis procedure by repeated recrystallization, but can still be present as impurity in d,l-isomer. Due to the lack of a suitable chromatographic method for analysis of the isomeric purity of 99mTc-exametazime preparations, United States Pharmacopoeia 25 (USP 25) prescribes a biological test in rats for quality control purpose. In this study, we developed a suitable high-performance liquid chromatography (HPLC) method which allows to demonstrate the relative amounts of d,l- and meso-isomer in 99mTc-exametazime and so obviates the need for a biodistribution test in animals as part of the quality control. Due to the low concentrations in which 99mTc-d,l-HMPAO is obtained (typically 2-6 ng/ml), confirmation of the identity of 99mTc-d,l-HMPAO in the monograph of the European Pharmacopoeia is now performed only indirectly by TLC and assessment of its retention time on RP-HPLC. To investigate the potential of radio-LC-MS for assessment of the identity of 99mTc-exametazime, 99mTc-d,l-HMPAO and 99mTc-meso-HMPAO prepared using a Tc-rich eluate were analyzed using a radio-LC-MS system equipped with a time-of-flight mass spectrometer with electrospray ionization. The main peak in the radiometric channel coincided with the molecular ion mass of 99mTc-d,l-HMPAO in the mass spectrometer channel and the measured accurate mass differed only by 0.26 ppm from the theoretical mass. The identity of 99mTc-meso-HMPAO was also confirmed. Thus, radio-LC-MS allowed

  5. Poor accumulation of technetium-99m glucoheptonate in sarcoidosis and other diffuse infiltrative lung diseases as compared with gallium-67 citrate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vorne, M.; Sahlstroem, K.A.; Alanko, K.

    1988-02-01

    Forty-two patients with diffuse infiltrative lung diseases were imaged with Ga-67 citrate and Tc-99m glucoheptonate (GH). Twenty patients had sarcoidosis, six had fibrosis, six had tuberculosis, nine had lung infiltration, and one had pleural empyema. The main difference between Ga-67 and Tc-99m GH was the much greater uptake of Ga-67 in sarcoidosis than that of Tc-99m GH. Fifteen patients with sarcoidosis had positive Ga-67 scans but only six had positive Tc-99m GH scans. The results in other diffuse infiltrative lung diseases were almost equal with Ga-67 and Tc-99m GH. Although Tc-99m GH is less expensive and simpler to use, itmore » is not an adequate substitute for Ga-67 in diffuse infiltrative lung diseases.« less

  6. A novel approach to infection imaging using a synthetic Tc-99m-labeled leukotactic peptide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Som, P.; Oster, Z.H.; Sharma, S.

    1996-05-01

    RMT1, a synthetic peptide binding to PMN and macrophage receptors was labeled with Tc-99m and investigated as a potential imaging agent for abscess and inflammation. Experimental abscesses were induced in rabbits and dogs by turpentine and E.coli injection. After injection of Tc-99m-RMT1 two and twelve day old abscesses were visualized within 20 min. In initial studies, a dose of 30 {mu}g of peptide/3 mCi was used. This amount was subsequently reduced to 1.5 {mu}g peptide with same amount of Tc-99m yielding similar imaging results. Technetium-99m-IgG and Tc-99m-MAG-3 were used as positive and negative controls, respectively. After injection of IgG abscessesmore » were visualized but activity in blood was always higher than in abscess. When using Tc-99m RMT1 rapid abscess visualization and faster blood clearance was observed. The accumulation of RMT1 was monophasic, i.e., following the initial visualization, activity continued to build up continuously for 1{1/2} hr. Tc-99m-MAG3 accumulated initially in abscess, but activity washed out. In dogs, RMT1 blood clearance showed three components: a fast component with t{1/2}=1.9 min, 73%, intermediate t{1/2}=22 min, 24.5% and slow component, t{1/2}=115, 9.5% with 3 hours cumulative urine excretion of 40-51%. RMT1 appears to be more advantageous than currently available methods because of rapidity of imaging, simpler preparation before injection and will probably be less expensive and time consuming compared to labeled WBC. These results indicate that clinical experiments are warranted.« less

  7. Low-noise low-jitter 32-pixels CMOS single-photon avalanche diodes array for single-photon counting from 300 nm to 900 nm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scarcella, Carmelo; Tosi, Alberto, E-mail: alberto.tosi@polimi.it; Villa, Federica

    2013-12-15

    We developed a single-photon counting multichannel detection system, based on a monolithic linear array of 32 CMOS SPADs (Complementary Metal-Oxide-Semiconductor Single-Photon Avalanche Diodes). All channels achieve a timing resolution of 100 ps (full-width at half maximum) and a photon detection efficiency of 50% at 400 nm. Dark count rate is very low even at room temperature, being about 125 counts/s for 50 μm active area diameter SPADs. Detection performance and microelectronic compactness of this CMOS SPAD array make it the best candidate for ultra-compact time-resolved spectrometers with single-photon sensitivity from 300 nm to 900 nm.

  8. Photon correlation in single-photon frequency upconversion.

    PubMed

    Gu, Xiaorong; Huang, Kun; Pan, Haifeng; Wu, E; Zeng, Heping

    2012-01-30

    We experimentally investigated the intensity cross-correlation between the upconverted photons and the unconverted photons in the single-photon frequency upconversion process with multi-longitudinal mode pump and signal sources. In theoretical analysis, with this multi-longitudinal mode of both signal and pump sources system, the properties of the signal photons could also be maintained as in the single-mode frequency upconversion system. Experimentally, based on the conversion efficiency of 80.5%, the joint probability of simultaneously detecting at upconverted and unconverted photons showed an anti-correlation as a function of conversion efficiency which indicated the upconverted photons were one-to-one from the signal photons. While due to the coherent state of the signal photons, the intensity cross-correlation function g(2)(0) was shown to be equal to unity at any conversion efficiency, agreeing with the theoretical prediction. This study will benefit the high-speed wavelength-tunable quantum state translation or photonic quantum interface together with the mature frequency tuning or longitudinal mode selection techniques.

  9. Positioning irrigation of contrast cystography for diagnosis of occult vesicoureteric reflux: association with technetium-99m dimercaptosuccinic acid scans.

    PubMed

    Berger, Christoph; Becker, Tanja; Koen, Mark; Zeino, Mazen; Fitz, Friedrich; Beheshti, Mohsen; Wolf-Kohlmeier, Iris; Haim, Silke; Riccabona, Marcus

    2013-12-01

    Positioning irrigation of contrast (PIC) cystography identifies occult or PIC vesicoureteral reflux (PIC-VUR) in children with recurrent febrile urinary tract infections (UTI) but no vesicoureteric reflux (VUR) on standard voiding cystourethrogram (VCUG). We sought to identify the relationship between PIC-VUR and renal scarring in technetium-99m dimercaptosuccinic acid (DMSA) scans. We retrospectively analysed PIC cystograms and DMSA scans for 154 kidneys in 81 children (65 girls; 16 boys; median age, 4.7 years; range, 0.9-15.2). Renal scarring was graded on a scale of 0-3. DMSA scans were pathologic in 66 patients (81%). Children had experienced mean 3.8 febrile UTI (range 1-25). Forty-seven (58%) children had a history of reflux, including 15 (19%) with previous anti-reflux operations. Indications for PIC cystography were recurrence of febrile UTI after either bilateral negative VCUG (66 children) or unilateral VUR (15 children) with contralateral/bilateral scarring or reflux that had changed sides in subsequent VCUGs. PIC-VUR was bilateral in 63, unilateral in 12, and absent in 6 children. Statistically significant associations between PIC-VUR grade and severity of renal scarring were identified in inter-individual (n = 77, p = 0.017) and intra-individual (refluxing vs. nonrefluxing kidney; n = 12, p = 0.008) analyses. After excluding patients with history of VUR, statistical significance was maintained in inter-individual analysis (n = 49; p = 0.018). The data suggest an association between PIC-VUR and severity of renal scarring, and legitimise the use of PIC cystography in children with renal scarring due to recurrent febrile UTI but negative findings on VCUG. Copyright © 2012 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  10. Deep liquid-chromatographic purification of uranium extract from technetium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Volk, V.; Dvoeglazov, K; Podrezova, L.

    The recycling of uranium in the nuclear fuel cycle requires the removal of a number of radioactive and stable impurities like {sup 99}Tc from spent fuels. In order to improve the grade of uranium extract purification from technetium the method of liquid chromatography and the apparatus for its performance have been developed. Process of technetium extraction and concentrating in aqueous solution containing reducing agent has been studied on simulated solutions (U-Tc-HNO{sub 3}-30% TBP-isoparM). The dynamic tests of the method have been carried out on the laboratory unit. Solution of diformyl-hydrazine in nitric acid was used as a stationary phase. Silicamore » gel with specific surface of 186 m{sup 2}/g was used as a carrier of the stationary phase. It is shown that the volume of purified extract increases as the solution temperature increases, concentration of reducing agent increases and extract flow rate decreases. It is established that the technetium content in uranium by this method could achieve a value below 0.3 ppm. Some variants of overload and composition of the stationary phase containing the extracted technetium have been offered and tested. It is defined that the method provides reduction of processing medium-active wastes by more than 10 times during finish refining process. (authors)« less

  11. Early myocardial damage assessment in dystrophinopathies using (99)Tc(m)-MIBI gated myocardial perfusion imaging.

    PubMed

    Zhang, Li; Liu, Zhe; Hu, Ke-You; Tian, Qing-Bao; Wei, Ling-Ge; Zhao, Zhe; Shen, Hong-Rui; Hu, Jing

    2015-01-01

    Early detection of muscular dystrophy (MD)-associated cardiomyopathy is important because early medical treatment may slow cardiac remodeling and attenuate symptoms of cardiac dysfunction; however, no sensitive and standard diagnostic method for MD at an earlier stage has been well-recognized. Thus, the aim of this study was to test the early diagnostic value of technetium 99m-methoxyisobutylisonitrile ((99)Tc(m)-MIBI) gated myocardial perfusion imaging (G-MPI) for MD. Ninety-one patients underwent (99)Tc(m)-MIBI G-MPI examinations when they were diagnosed with Duchenne muscular dystrophy (DMD) (n=77) or Becker muscular dystrophy (BMD; n=14). (99)Tc(m)-MIBI G-MPI examinations were repeated in 43 DMD patients who received steroid treatments for 2 years as a follow-up examination. Myocardial defects were observed in nearly every segment of the left ventricular wall in both DMD and BMD patients compared with controls, especially in the inferior walls and the apices by using (99)Tc(m)-MIBI G-MPI. Cardiac wall movement impairment significantly correlated with age in the DMD and BMD groups (r s=0.534 [P<0.05] and r s=0.784 [P<0.05], respectively). Intermittent intravenous doses of glucocorticoids and continuation with oral steroid treatments significantly improved myocardial function in DMD patients (P<0.05), but not in BMD patients. (99)Tc(m)-MIBI G-MPI is a sensitive and safe approach for early evaluation of cardiomyopathy in patients with DMD or BMD, and can serve as a candidate method for the evaluation of progression, prognosis, and assessment of the effect of glucocorticoid treatment in these patients.

  12. Single-photon emission computed tomography enhanced Tc-99m-pertechnetate disodium-labelled red blood cell scintigraphy in the localization of small intestine bleeding: a single-centre twelve-year study.

    PubMed

    Dolezal, Jiri; Vizda, Jaroslav; Kopacova, Marcela

    2011-01-01

    To present our experience with the detection of bleeding in the small intestine by means of scintigraphy with in vivo-labelled red blood cells (RBCs) in the period of 1998-2009. A 12-year prospective study was accomplished with 40 patients (23 men, 17 women, aged 12-91, mean 56 years) who had lower gastrointestinal bleeding (obscure-overt bleeding) and underwent scintigraphy with in vivo-labelled RBCs by means of technetium 99m. The scintigraphy was usually performed after other diagnostic tests had failed to locate the bleeding. A total of 26 patients had a positive scintigraphy with in vivo-labelled RBCs and 14 patients had negative scintigraphy. The final diagnosis was confirmed in 20 of 26 patients with a positive scintigraphy by push enteroscopy (6/20), intraoperative enteroscopy (7/20), surgery (4/20), duodenoscopy (1/20), double-balloon enteroscopy (1/20) and X-ray angiography (1/20). The correct location of the bleeding site was identified by RBC scintigraphy in 15 of 20 (75%) patients with the confirmed source. The locations of the bleeding site identified by scintigraphy and enteroscopy (push, intraoperative) and surgical investigations were highly correlated in patients with a positive scintigraphy within the first 3 h. Eleven of the 20 correctly localized studies and none of the incorrectly localized studies were positive in the dynamic phase of imaging. In 5 patients (all erroneously localized), scintigraphy was positive only at a period longer than 18 h. RBC scintigraphy is an effective imaging modality in localizing lower gastrointestinal bleeding in patients for whom other diagnostic tests have failed to locate the bleeding. RBC scintigraphy can be successful in the detection of bleeding sites in the small intestine. Copyright © 2011 S. Karger AG, Basel.

  13. Single photon quantum cryptography.

    PubMed

    Beveratos, Alexios; Brouri, Rosa; Gacoin, Thierry; Villing, André; Poizat, Jean-Philippe; Grangier, Philippe

    2002-10-28

    We report the full implementation of a quantum cryptography protocol using a stream of single photon pulses generated by a stable and efficient source operating at room temperature. The single photon pulses are emitted on demand by a single nitrogen-vacancy color center in a diamond nanocrystal. The quantum bit error rate is less that 4.6% and the secure bit rate is 7700 bits/s. The overall performances of our system reaches a domain where single photons have a measurable advantage over an equivalent system based on attenuated light pulses.

  14. Tuning single-photon sources for telecom multi-photon experiments.

    PubMed

    Greganti, Chiara; Schiansky, Peter; Calafell, Irati Alonso; Procopio, Lorenzo M; Rozema, Lee A; Walther, Philip

    2018-02-05

    Multi-photon state generation is of great interest for near-future quantum simulation and quantum computation experiments. To-date spontaneous parametric down-conversion is still the most promising process, even though two major impediments still exist: accidental photon noise (caused by the probabilistic non-linear process) and imperfect single-photon purity (arising from spectral entanglement between the photon pairs). In this work, we overcome both of these difficulties by (1) exploiting a passive temporal multiplexing scheme and (2) carefully optimizing the spectral properties of the down-converted photons using periodically-poled KTP crystals. We construct two down-conversion sources in the telecom wavelength regime, finding spectral purities of > 91%, while maintaining high four-photon count rates. We use single-photon grating spectrometers together with superconducting nanowire single-photon detectors to perform a detailed characterization of our multi-photon source. Our methods provide practical solutions to produce high-quality multi-photon states, which are in demand for many quantum photonics applications.

  15. Quantitation of left ventricular ejection fraction reserve from early gated regadenoson stress Tc-99m high efficiency SPECT

    PubMed Central

    Brodov, Yafim; Fish, Mathews; Rubeaux, Mathieu; Otaki, Yuka; Gransar, Heidi; Lemley, Mark; Gerlach, Jim; Berman, Daniel; Germano, Guido; Slomka, Piotr

    2016-01-01

    Background Ejection fraction (EF) reserve has been found to be a useful adjunct for identifying high risk coronary artery disease in cardiac positron emission tomography (PET). We aimed to evaluate EF reserve obtained from technetium-99m sestamibi (Tc-99m) high-efficiency (HE) SPECT. Methods Fifty patients (mean age 69 y) undergoing regadenoson same-day rest (8–11 mCi)/stress (32–42mCi) Tc-99m gated HE SPECT were enrolled. Stress imaging was started one min after sequential intravenous regadenoson 0.4mg and Tc-99m injection, and was composed of five 2 min supine gated acquisitions followed by two 4 min supine and upright images. Ischemic total perfusion deficit (ITPD) ≥ 5 % was considered as significant ischemia. Results Significantly lower mean EF reserve was obtained in the 5th and 9th min after regadenoson bolus in patients with significant ischemia versus patients without (5th min: −4.2 ± 4.6% vs. 1.3 ± 6.6%, p = 0.006; 9th min: −2.7 ± 4.8% vs. 2.0 ± 6.6%, p = 0.03). Conclusions Negative EF reserve obtained between 5th and 9th min of regadenoson stress demonstrated best concordance with significant ischemia and may be a promising tool for detection of myocardial stunning with Tc-99m HE-SPECT. PMID:27387521

  16. Quantitation of left ventricular ejection fraction reserve from early gated regadenoson stress Tc-99m high-efficiency SPECT.

    PubMed

    Brodov, Yafim; Fish, Mathews; Rubeaux, Mathieu; Otaki, Yuka; Gransar, Heidi; Lemley, Mark; Gerlach, Jim; Berman, Daniel; Germano, Guido; Slomka, Piotr

    2016-12-01

    Ejection fraction (EF) reserve has been found to be a useful adjunct for identifying high risk coronary artery disease in cardiac positron emission tomography (PET). We aimed to evaluate EF reserve obtained from technetium-99m sestamibi (Tc-99m) high-efficiency (HE) SPECT. Fifty patients (mean age 69 years) undergoing regadenoson same-day rest (8-11 mCi)/stress (32-42 mCi) Tc-99m gated HE SPECT were enrolled. Stress imaging was started 1 minute after sequential intravenous regadenoson .4 mg and Tc-99m injections, and was composed of five 2 minutes supine gated acquisitions followed by two 4 minutes supine and upright images. Ischemic total perfusion deficit (ITPD) ≥5 % was considered as significant ischemia. Significantly lower mean EF reserve was obtained in the 5th and 9th minute after regadenoson bolus in patients with significant ischemia vs patients without (5th minute: -4.2 ± 4.6% vs 1.3 ± 6.6%, P = .006; 9th minute: -2.7 ± 4.8% vs 2.0 ± 6.6%, P = .03). Negative EF reserve obtained between 5th and 9th minutes of regadenoson stress demonstrated best concordance with significant ischemia and may be a promising tool for detection of transient ischemic functional changes with Tc-99m HE-SPECT.

  17. Absorbed radiation dose in adults from iodine-131 and iodine-123 orthoiodohippurate and technetium-99m DTPA renography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carlsen, O.

    1988-03-01

    A mathematic model for evaluation of absorbed dose in radionuclide renography has been developed and programmed for automatic calculation in the computer. Input data to the model are readily available from the results of the renography and, hence, the method described is suitable for individual dose determinations in adults. Apart from the situation with very considerable outflow obstructions (/sup 131/I)OIH single probe renography involves a 15-20 times smaller dose to radiation sensitive organs than (/sup 123/I)OIH gamma camera renography. Further, the latter examination results in a 2-10 times smaller dose than (/sup 99m/Tc)DTPA gamma camera renography under normal outflow conditions.more » Absorbed renal dose is large, approximately 70 mGy, in the three renographies in the borderline case with total outflow obstructions. For comparison, i.v. pyelography, which is the x-ray examination often used instead of radionuclide renography, involves an absorbed dose to ovaries 10-1000 times larger than in radionuclide renography« less

  18. The distribution of 99mTc-EHDP in the tissues of the dog and its application in the assessment of fracture healing.

    PubMed

    Hughes, S

    1977-07-01

    Technetium-labelled ethane hydroxydiphosphonate (99mTc-EHDP) is a commonly used bone-scanning agent. After injection it leaves the circulation to enter bone and to be cleared by the kidney. The transcapillary exchange of 99mTc-EHDP in bone was examined and found to be low. The capillary movement was compared with that of sucrose, a freely diffusible substance, and it was found that the permeability ratio of 99mTc-EHDP to 14C-sucrose was similar to the diffusion coefficient ratio, suggesting that 99mTc-EHDP passes through the capillaries by the process of passive diffusion. The renal clearance of 99mTc-EHDP was 24 ml/min and was unaffected by the action of parathyroid hormone. After a fracture the bone blood flow increases, although the transcapillary extraction of 99mTc-EHDP does not change. This is because there is an increase, from recruitment and dilatation of capillaries, in the surface area available for exchange. Therefore the increased isotopic activity seen on a bone scan after a fracture is primarily related to an increase in bone blood supply from capillary enhancement within the cortex.

  19. Biodistribution and pharmacokinetics of the (99m)Tc labeled human elastase inhibitor, elafin, in rats.

    PubMed

    Kaschwich, Mark; Lützen, Ulf; Zhao, Yi; Tjiong, Angelina; Marx, Marlies; Haenisch, Sierk; Wiedow, Oliver; Preuss, Stefanie; Culman, Juraj; Zuhayra, Maaz

    2016-04-01

    Elafin is a potent reversible inhibitor of the pro-inflammatory proteases leukocyte elastase and protease 3. It is currently in clinical development for the use in postoperative inflammatory diseases. We investigated the pharmacokinetics of (99m)Tc-labeled elafin ((99m)Tc-Elafin) in blood and individual organs in rat after bolus intravenous injection using the single photon emission tomography (SPECT). (99m)Tc-Elafin predominantly accumulated in the kidney reaching a maximum of 8.5% ± 0.1% of the injected dose per gram (ID/g) at 5 min post injection (p.i) and decreased only slowly during 24 h. In contrast, the initially high radio activity recorded in the other organs rapidly decreased parallel to the radioactivity detected in blood. The blood kinetics fits to a two compartment kinetics model. The radio activity in the dissected kidney was 4.98 ± 1.24%ID/g 24 h p.i, while in other organs, including the brain, no accumulation of (99m)Tc-Elafin was detected. At this time point 30% of the detected radioactivity in the kidney was identified to be not metabolized (99m)Tc-Elafin. In conclusion, the blood and organ-specific kinetic data provide a basis for planning of adequate dosing regimens and the high accumulation of intact elafin in the kidney favors clinical developments targeting inflammatory kidney diseases, such as chronic allograft nephropathy after kidney transplantation. Copyright © 2016 The Japanese Society for the Study of Xenobiotics. Published by Elsevier Ltd. All rights reserved.

  20. Effects of CT-based attenuation correction of rat microSPECT images on relative myocardial perfusion and quantitative tracer uptake

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strydhorst, Jared H., E-mail: jared.strydhorst@gmail.com; Ruddy, Terrence D.; Wells, R. Glenn

    2015-04-15

    Purpose: Our goal in this work was to investigate the impact of CT-based attenuation correction on measurements of rat myocardial perfusion with {sup 99m}Tc and {sup 201}Tl single photon emission computed tomography (SPECT). Methods: Eight male Sprague-Dawley rats were injected with {sup 99m}Tc-tetrofosmin and scanned in a small animal pinhole SPECT/CT scanner. Scans were repeated weekly over a period of 5 weeks. Eight additional rats were injected with {sup 201}Tl and also scanned following a similar protocol. The images were reconstructed with and without attenuation correction, and the relative perfusion was analyzed with the commercial cardiac analysis software. The absolutemore » uptake of {sup 99m}Tc in the heart was also quantified with and without attenuation correction. Results: For {sup 99m}Tc imaging, relative segmental perfusion changed by up to +2.1%/−1.8% as a result of attenuation correction. Relative changes of +3.6%/−1.0% were observed for the {sup 201}Tl images. Interscan and inter-rat reproducibilities of relative segmental perfusion were 2.7% and 3.9%, respectively, for the uncorrected {sup 99m}Tc scans, and 3.6% and 4.3%, respectively, for the {sup 201}Tl scans, and were not significantly affected by attenuation correction for either tracer. Attenuation correction also significantly increased the measured absolute uptake of tetrofosmin and significantly altered the relationship between the rat weight and tracer uptake. Conclusions: Our results show that attenuation correction has a small but statistically significant impact on the relative perfusion measurements in some segments of the heart and does not adversely affect reproducibility. Attenuation correction had a small but statistically significant impact on measured absolute tracer uptake.« less

  1. CMOS-compatible photonic devices for single-photon generation

    NASA Astrophysics Data System (ADS)

    Xiong, Chunle; Bell, Bryn; Eggleton, Benjamin J.

    2016-09-01

    Sources of single photons are one of the key building blocks for quantum photonic technologies such as quantum secure communication and powerful quantum computing. To bring the proof-of-principle demonstration of these technologies from the laboratory to the real world, complementary metal-oxide-semiconductor (CMOS)-compatible photonic chips are highly desirable for photon generation, manipulation, processing and even detection because of their compactness, scalability, robustness, and the potential for integration with electronics. In this paper, we review the development of photonic devices made from materials (e.g., silicon) and processes that are compatible with CMOS fabrication facilities for the generation of single photons.

  2. Indistinguishable and efficient single photons from a quantum dot in a planar nanobeam waveguide

    NASA Astrophysics Data System (ADS)

    KiršanskÄ--, Gabija; Thyrrestrup, Henri; Daveau, Raphaël S.; Dreeßen, Chris L.; Pregnolato, Tommaso; Midolo, Leonardo; Tighineanu, Petru; Javadi, Alisa; Stobbe, Søren; Schott, Rüdiger; Ludwig, Arne; Wieck, Andreas D.; Park, Suk In; Song, Jin D.; Kuhlmann, Andreas V.; Söllner, Immo; Löbl, Matthias C.; Warburton, Richard J.; Lodahl, Peter

    2017-10-01

    We demonstrate a high-purity source of indistinguishable single photons using a quantum dot embedded in a nanophotonic waveguide. The source features a near-unity internal coupling efficiency and the collected photons are efficiently coupled off chip by implementing a taper that adiabatically couples the photons to an optical fiber. By quasiresonant excitation of the quantum dot, we measure a single-photon purity larger than 99.4 % and a photon indistinguishability of up to 94 ±1 % by using p -shell excitation combined with spectral filtering to reduce photon jitter. A temperature-dependent study allows pinpointing the residual decoherence processes, notably the effect of phonon broadening. Strict resonant excitation is implemented as well as another means of suppressing photon jitter, and the additional complexity of suppressing the excitation laser source is addressed. The paper opens a clear pathway towards the long-standing goal of a fully deterministic source of indistinguishable photons, which is integrated on a planar photonic chip.

  3. Technetium-99m colloidal bismuth subcitrate: A novel method for the evaluation of peptic ulcer disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vasquez, T.E.; Lyons, K.P.; Raiszadeh, M.

    1984-01-01

    The therapeutic agent colloidal bismuth subcitrate (CBS) selectively binds to peptic ulcers. The authors have developed a method for labeling this agent with Tc-99m. Chromatographic quality control studies of the agent on silica gel coated strips (ITLC-SG) showed that more than 97% of Tc-99m was bound to CBS. During in-vitro stability testing, the radio-label was stable for a minimum of 6 hours. The chromatographic findings are in agreement with the in-vivo distribution of the agent which showed no significant radioactivity in thyroid, kidneys, liver, or bladder. The resulting Tc-99m-CBS solution is administered orally in drinking water. Preliminary animal studies havemore » been conducted on 5 adult 3 kg New Zealand rabbits sedated with 50 mg Ketamine I.M. The rabbits were intubated with I.V. tubing advanced to the stomach. They were given a gastric erosive suspension of 600-1000 mg/kg of pulverized ASA in 10 cc tap water. Four hours later they were given 3-4 mCi of the radiotracer in a 5 cc volume of water. Serial in-vivo images were obtained for 2 hours which included thyroid, abdomen, and urinary bladder. Next the stomachs were excised, opened along the greater curvature, imaged, vigorously washed and reimaged. All 5 rabbits showed avid localized binding of radiotracer which remained fixed even with vigorous washing. Areas of normal appearing mucosa were relatively devoid of radiotracer. This new compound may have significant clinical usefulness in the detection of peptic ulcer disease. In addition, such a non-invasive technique, carrying none of the risks or discomfort of endoscopy could also find application in the evaluation of the response to therapy.« less

  4. Differences between the macroscopic and tracer level chemistry of rhenium and technetium: contrasting cage isomerisation behaviour of Re(I) and Tc(I) carborane complexes.

    PubMed

    Armstrong, Andrea F; Valliant, John F

    2010-09-21

    Carboranes form stable complexes with the [M(CO)(3)](+) (M = (99m)Tc, Re) core and are viable ligands for the development of targeted radiopharmaceuticals. (99m)Tc-carborane complexes were found to exhibit substantially different 1,2-->1,7 cage isomerisation behaviour than their Re counterparts, challenging the validity of the routine use of rhenium as a surrogate for the development of technetium-99m based molecular imaging agents.

  5. Multi-photon absorption limits to heralded single photon sources

    PubMed Central

    Husko, Chad A.; Clark, Alex S.; Collins, Matthew J.; De Rossi, Alfredo; Combrié, Sylvain; Lehoucq, Gaëlle; Rey, Isabella H.; Krauss, Thomas F.; Xiong, Chunle; Eggleton, Benjamin J.

    2013-01-01

    Single photons are of paramount importance to future quantum technologies, including quantum communication and computation. Nonlinear photonic devices using parametric processes offer a straightforward route to generating photons, however additional nonlinear processes may come into play and interfere with these sources. Here we analyse spontaneous four-wave mixing (SFWM) sources in the presence of multi-photon processes. We conduct experiments in silicon and gallium indium phosphide photonic crystal waveguides which display inherently different nonlinear absorption processes, namely two-photon (TPA) and three-photon absorption (ThPA), respectively. We develop a novel model capturing these diverse effects which is in excellent quantitative agreement with measurements of brightness, coincidence-to-accidental ratio (CAR) and second-order correlation function g(2)(0), showing that TPA imposes an intrinsic limit on heralded single photon sources. We build on these observations to devise a new metric, the quantum utility (QMU), enabling further optimisation of single photon sources. PMID:24186400

  6. Rhenium solubility in borosilicate nuclear waste glass: implications for the processing and immobilization of technetium-99.

    PubMed

    McCloy, John S; Riley, Brian J; Goel, Ashutosh; Liezers, Martin; Schweiger, Michael J; Rodriguez, Carmen P; Hrma, Pavel; Kim, Dong-Sang; Lukens, Wayne W; Kruger, Albert A

    2012-11-20

    The immobilization of technetium-99 ((99)Tc) in a suitable host matrix has proven to be a challenging task for researchers in the nuclear waste community around the world. In this context, the present work reports on the solubility and retention of rhenium, a nonradioactive surrogate for (99)Tc, in a sodium borosilicate glass. Glasses containing target Re concentrations from 0 to 10,000 ppm [by mass, added as KReO(4) (Re(7+))] were synthesized in vacuum-sealed quartz ampules to minimize the loss of Re from volatilization during melting at 1000 °C. The rhenium was found as Re(7+) in all of the glasses as observed by X-ray absorption near-edge structure. The solubility of Re in borosilicate glasses was determined to be ~3000 ppm (by mass) using inductively coupled plasma optical emission spectroscopy. At higher rhenium concentrations, additional rhenium was retained in the glasses as crystalline inclusions of alkali perrhenates detected with X-ray diffraction. Since (99)Tc concentrations in a glass waste form are predicted to be <10 ppm (by mass), these Re results implied that the solubility should not be a limiting factor in processing radioactive wastes, assuming Tc as Tc(7+) and similarities between Re(7+) and Tc(7+) behavior in this glass system.

  7. Preparation and Evaluation of 99mTc-labeled Tridentate Chelates for Pre-targeting Using Bioorthogonal Chemistry.

    PubMed

    Bilton, Holly A; Ahmad, Zainab; Janzen, Nancy; Czorny, Shannon; Valliant, John F

    2017-02-04

    Pre-targeting combined with bioorthogonal chemistry is emerging as an effective way to create new radiopharmaceuticals. Of the methods available, the inverse electron demand Diels-Alder (IEDDA) cycloaddition between a radiolabeled tetrazines and trans-cyclooctene (TCO) linked to a biomolecule has proven to be a highly effective bioorthogonal approach to imaging specific biological targets. Despite the fact that technetium-99m remains the most widely used isotope in diagnostic nuclear medicine, there is a scarcity of methods for preparing 99m Tc-labeled tetrazines. Herein we report the preparation of a family of tridentate-chelate-tetrazine derivatives and their Tc(I) complexes. These hitherto unknown compounds were radiolabeled with 99m Tc using a microwave-assisted method in 31% to 83% radiochemical yield. The products are stable in saline and PBS and react rapidly with TCO derivatives in vitro. Their in vivo pre-targeting abilities were demonstrated using a TCO-bisphosphonate (TCO-BP) derivative that localizes to regions of active bone metabolism or injury. In murine studies, the 99m Tc-tetrazines showed high activity concentrations in knees and shoulder joints, which was not observed when experiments were performed in the absence of TCO-BP. The overall uptake in non-target organs and pharmacokinetics varied greatly depending on the nature of the linker and polarity of the chelate.

  8. Discovery of rhenium and masurium (technetium) by Ida Noddack-Tacke and Walter Noddack. Forgotten heroes of nuclear medicine.

    PubMed

    Biersack, H-J; Stelzner, F; Knapp, F F

    2015-01-01

    The history of the early identification of elements and their designation to the Mendeleev Table of the Elements was an important chapter in German science in which Ida (1896-1978) and Walter (1893-1960) Noddack played an important role in the first identification of rhenium (element 75, 1925) and technetium (element 43, 1933). In 1934 Ida Noddack was also the first to predict fission of uranium into smaller atoms. Although the Noddacks did not for some time later receive the recognition for the first identification of technetium-99m, their efforts have appropriately more recently been recognized. The discoveries of these early pioneers are even more astounding in light of the limited technologies and resources which were available during this period. The Noddack discoveries of elements 43 and 75 are related to the subsequent use of rhenium-188 (beta/gamma emitter) and technetium-99m (gamma emitter) in nuclear medicine. In particular, the theranostic relationship between these two generator-derived radioisotopes has been demonstrated and offers new opportunities in the current era of personalized medicine.

  9. Methylphenidate DAT binding in adolescents with Attention-Deficit/ Hyperactivity Disorder comorbid with Substance Use Disorder--a single photon emission computed tomography with [Tc(99m)]TRODAT-1 study.

    PubMed

    Szobot, Claudia M; Shih, Ming Chi; Schaefer, Thais; Júnior, Neivo; Hoexter, Marcelo Q; Fu, Ying Kai; Pechansky, Flávio; Bressan, Rodrigo A; Rohde, Luis A P

    2008-04-15

    Attention-Deficit/Hyperactivity Disorder (ADHD) is highly prevalent among adolescents with Substance Use Disorders (SUD). Effects of methylphenidate (MPH) on ADHD are attributed to its properties of blocking the dopamine transporter (DAT) in the striatum. However, it has been demonstrated that drug addiction is associated with dopaminergic system changes that may affect MPH brain effects, emphasizing the need to better understand MPH actions in subjects with ADHD+SUD. To evaluate the effect of an extended release formulation of MPH (MPH-SODAS) on DAT availability in 17 stimulant-naive ADHD adolescents with comorbid SUD (cannabis and cocaine). Subjects underwent two single photon emission computed tomography (SPECT) scans with [Tc(99m)]TRODAT-1, at baseline and after 3 weeks on MPH-SODAS. Clinical assessment for ADHD relied on the Swanson, Nolan and Pelham Scale - version IV (SNAP-IV). Caudate and putamen DAT binding potential (BP) was calculated. After 3 weeks on MPH-SODAS, there was a significant reduction of SNAP-IV total scores (p<0.001), and approximately 52% reductions of DAT BP at the left and right caudate. Similar decreases were found at the left and right putamen (p<0.001 for all analyses). This study shows that the magnitude of DAT blockade induced by MPH in this population is similar to what is found in ADHD patients without SUD comorbidity, providing neurobiological support for trials with stimulants in adolescents with ADHD+SUD, an important population excluded from studies.

  10. Fab(nimotuzumab)-HYNIC-99mTc: Antibody Fragmentation for Molecular Imaging Agents.

    PubMed

    Calzada, Victoria; García, María Fernanda; Alonso-Martínez, Luis Michel; Camachoc, Ximena; Goicochea, Enzo; Fernández, Marcelo; Castillo, Abmel Xiques; Díaz-Miqueli, Arlhee; Iznaga-Escobar, Normando; Montaña, René Leyva; Alonso, Omar; Gambini, Juan Pablo; Cabral, Pablo

    2016-01-01

    Finally, fast blood clearance nimotuzumab is a humanized monoclonal antibody that recognise, with high specific affinity, the epidermal growth factor receptor (EGF-R) which play an important role in the growth process associated with many solid tumors. In this work, the whole antibody was digested with papain in order to generate a Fab fragment, derivatized with NHS-HYNIC-Tfa and radiolabel with technetium-99m (99mTc) as a potential agent of molecular imaging of cancer. Both, whole and fragment radiolabels were in-vivo and in-vitro characterized. Radiolabeling conditions with Tricine as coligand and quality controls were assessed to confirm the integrity of the labeled fragment. Biodistribution and imaging studies in normal and spontaneous adenocarcinoma mice were performed at different times to determine the in-vivo characteristics of the radiolabel fragment. Tumor localization was visualized by conventional gamma camera imaging studies, and the results were compared with the whole antibody. Also, an immunoreactivity assay was carried out for both. The results showed clearly the integrity of the nimotuzumab fragment and the affinity by the receptor was verified. Fab(nimotuzumab)-HYNIC was obtained with high purity and a simple strategy of radiolabeling was performed. Finally, a fast blood clearance was observed in the biodistribution studies increasing the tumor uptake of Fab(nimotuzumab)- HYNIC-99mTc over time, with tumor/muscle ratios of 3.81 ± 0.50, 5.16 ± 1.97 and 6.32 ± 1.98 at 1 h, 4 h and 24 h post injection. Urinary excretion resulted in 32.89 ± 3.91 %ID eliminated at 24 h. Scintigraphy images showed uptake in the tumor and the activity in non-target organs was consistent with the biodistribution data at the same time points. Hence, these preliminary results showed important further characteristic of Fab(nimotuzumab)-HYNIC-99mTc as a molecular imaging agent of cancer.

  11. Comparative evaluation of technetium-99m-diethylenetriaminepentaacetic acid renal dynamic imaging versus the Modification of Diet in Renal Disease equation and the Chronic Kidney Disease Epidemiology Collaboration equation for the estimation of GFR.

    PubMed

    Huang, Qi; Chen, Yunshuang; Zhang, Min; Wang, Sihe; Zhang, Weiguang; Cai, Guangyan; Chen, Xiangmei; Sun, Xuefeng

    2018-04-01

    We compared the performance of technetium-99m-diethylenetriaminepentaacetic acid ( 99m Tc-DTPA) renal dynamic imaging (RDI), the MDRD equation, and the CKD EPI equation to estimate glomerular filtration rate (GFR). A total of 551 subjects, including CKD patients and healthy individuals, were enrolled in this study. Dual plasma sample clearance method of 99m Tc-DTPA was used as the true value for GFR (tGFR). RDI and the MDRD and CKD EPI equations for estimating GFR were compared and evaluated. Data indicate that RDI and the MDRD equation underestimated GFR and CKD EPI overestimated GFR. RDI was associated with significantly higher bias than the MDRD and CKD EPI equations. The regression coefficient, diagnostic precision, and consistency of RDI were significantly lower than either equation. RDI and the MDRD equation underestimated GFR to a greater degree in subjects with tGFR ≥ 90 ml/min/1.73 m 2 compared with the results obtained from all subjects. In the tGFR60-89 ml/min/1.73 m 2 group, the precision of RDI was significantly lower than that of both equations. In the tGFR30-59 ml/min/1.73 m 2 group, RDI had the least bias, the most precision, and significantly higher accuracy compared with either equation. In tGFR < 30 ml/min/1.73 m 2 , the three methods had similar performance and were not significantly different. RDI significantly underestimates GFR and performs no better than MDRD and CKD EPI equations for GFR estimation; thus, it should not be recommended as a reference standard against which other GFR measurement methods are assessed. However, RDI better estimates GFR than either equation for individuals in the tGFR30-59 ml/min/1.73 m 2 group and thus may be helpful to distinguish stage 3a and 3b CKD.

  12. PREDICTION OF RELAPSE FROM HYPERTHYROIDISM FOLLOWING ANTITHYROID MEDICATION WITHDRAWAL USING TECHNETIUM THYROID UPTAKE SCANNING.

    PubMed

    Nakhjavani, Manouchehr; Abdollahi, Soraya; Farzanefar, Saeed; Abousaidi, Mohammadtagi; Esteghamati, Alireza; Naseri, Maryam; Eftekhari, Mohamad; Abbasi, Mehrshad

    2017-04-02

    Technetium thyroid uptake (TTU) is not inhibited by antithyroid drugs (ATD) and reflects the degree of thyroid stimulation. We intended to predict the relapse rate from hyperthyroidism based on TTU measurement. Out of 44 initially enrolled subjects, 38 patients aged 41.6 ± 14.6 with Graves disease (duration: 84 ± 78 months) completed the study. TTU was performed with 40-second imaging of the neck and mediastinum 20 minutes after injection of 1 mCi technetium-99m pertechnetate. TTU was measured as the percentage of the count of activity accumulated in the thyroidal region minus the mediastinal background uptake to the count of 1 mCi technetium-99m under the same acquisition conditions. Then methimazole was stopped and patients were followed. The optimal TTU cutoff value for Graves relapse prediction was calculated using Youden's J statistic. Hyperthyroidism relapsed in 11 (28.9%) patients 122 ± 96 (range: 15-290) days post-ATD withdrawal. The subjects in remission were followed for 209 ± 81 days (range: 88-390). TTU was significantly higher in patients with forthcoming relapse (12.0 ± 8.0 vs. 3.9 ± 2.0, P = .007). The difference was significant after adjustment for age, sex, history of previous relapse, disease duration, and thyroid-stimulating hormone (TSH) levels before withdrawal. The area under the receiver operative characteristic (ROC) curve was 0.87. The optimal TTU cutoff value for classification of subjects with relapse and remission was 8.7 with sensitivity, specificity, and positive and negative predictive value of 73%, 100%, 100%, and 90%, respectively (odds ratio [OR] = 10.0; 95% confidence interval [CI]: 3.4-29.3). TTU evaluation in hyperthyroid patients receiving antithyroid medication is an accurate and practical method for predicting relapse after ATD withdrawal. ATD = antithyroid drugs RIU = radio-iodine uptake TSH = thyroid-stimulating hormone TSI = thyroid-stimulating immunoglobulin TTU = technetium thyroid uptake.

  13. On-Demand Single Photons with High Extraction Efficiency and Near-Unity Indistinguishability from a Resonantly Driven Quantum Dot in a Micropillar.

    PubMed

    Ding, Xing; He, Yu; Duan, Z-C; Gregersen, Niels; Chen, M-C; Unsleber, S; Maier, S; Schneider, Christian; Kamp, Martin; Höfling, Sven; Lu, Chao-Yang; Pan, Jian-Wei

    2016-01-15

    Scalable photonic quantum technologies require on-demand single-photon sources with simultaneously high levels of purity, indistinguishability, and efficiency. These key features, however, have only been demonstrated separately in previous experiments. Here, by s-shell pulsed resonant excitation of a Purcell-enhanced quantum dot-micropillar system, we deterministically generate resonance fluorescence single photons which, at π pulse excitation, have an extraction efficiency of 66%, single-photon purity of 99.1%, and photon indistinguishability of 98.5%. Such a single-photon source for the first time combines the features of high efficiency and near-perfect levels of purity and indistinguishabilty, and thus opens the way to multiphoton experiments with semiconductor quantum dots.

  14. Tc-99m Ethylenedicysteine and Tc-99m Dimercaptosuccinic Acid Scintigraphy-Comparison of the Two for Detection of Scarring and Differential Cortical Function.

    PubMed

    Dharmalingam, Anitha; Pawar, Shwetal U; Parelkar, Sandesh V; Shetye, Suruchi S; Ghorpade, Mangala K; Tilve, Gundu H

    2017-01-01

    The differential cortical function obtained by Tc-99m EC is comparable to that of Tc-99m DMSA. However, identification of scars on Tc-99m EC images needs to be studied. The aim of the study is to evaluate role of Tc-99m EC for detection of scarring and differential cortical function by comparing with Tc-99m DMSA. Prospective observational study of recurrent UTI; minimum 6 weeks after acute episode; when urine examination is negative for pus cells. Forty-seven children with normal positioned kidneys underwent Tc-99m EC and DMSA scintigraphy. The DRF and cortical phase images of both studies in the same image matrix size were evaluated by two independent observers for scarring; Tc-99m DMSA was considered as the gold standard. MS Excel 2007 and GraphPad Instat V3.1 and ROC analysis. There was no significant difference in the detection of scarring using two studies with Cohen's kappa coefficient (κ) 0.932. The sensitivity and specificity of Tc-99m EC for detection of scarring was 98.75% and 99.15%, respectively. There was good agreement between the differential cortical function calculated using two studies. The summed Tc-99m EC images with an acceptable high image contrast allow detection of cortical scarring in patients with normal kidney positions. It is an excellent single-modality comprehensive investigational agent for renal parenchymal defects, function, and excretion evaluation with the added advantages of lower cost, convenience, and low radiation exposure to the child.

  15. Single-Photon-Triggered Quantum Phase Transition

    NASA Astrophysics Data System (ADS)

    Lü, Xin-You; Zheng, Li-Li; Zhu, Gui-Lei; Wu, Ying

    2018-06-01

    We propose a hybrid quantum model combining cavity QED and optomechanics, which allows the occurrence of an equilibrium superradiant quantum phase transition (QPT) triggered by a single photon. This single-photon-triggered QPT exists in the cases of both ignoring and including the so-called A2 term; i.e., it is immune to the no-go theorem. It originally comes from the photon-dependent quantum criticality featured by the proposed hybrid quantum model. Moreover, a reversed superradiant QPT is induced by the competition between the introduced A2 term and the optomechanical interaction. This work offers an approach to manipulate QPT with a single photon, which should inspire the exploration of single-photon quantum-criticality physics and the engineering of new single-photon quantum devices.

  16. 99mTc Glucarate as a Potential Radiopharmaceutical Agent for Assessment of Tumor Viability: From Bench to the Bed Side

    PubMed Central

    Choudhury, Partha S.; Savio, E.; Solanki, K. K.; Alonso, O.; Gupta, A.; Gambini, J. P.; Doval, Dinesh; Sharma, P.; Dondi, M.

    2012-01-01

    Several radiotracers have been used for assessing cell death, whether by necrosis or apoptosis. 99mTc glucarate, which has initially been reported to be concentrating/accumulating in myocardial infarction or zones of cerebral injury, has also shown some tumor-seeking properties in a few preliminary studies. Under International Atomic Energy Agency (IAEA)'s coordinated research program, we report here the standardization, quality control, and clinical evaluation (detection, evaluation of response, and comparison with 18F Fluorodeoxyglucose) of this tracer in well-characterized lung cancer and head neck malignancies in a single-arm prospective observational study. Forty-seven patients (29 inoperable lung carcinoma and 18 head and neck malignancies) were prospectively enrolled and underwent 99mTc glucarate imaging [whole body planar and single-photon emission computed tomography of the region of interest] 4-5 hours after injection of 20 mCi of the radiopharmaceutical. Excellent 99mTc glucarate concentration was noted in the target lesion in lung cancer and head and neck malignancies. The sensitivity was found to be better in lung cancer. Avid concentration of tracer was seen in the metastatic sites. During response evaluation, the glucarate concentration correlated well with the clinical and other radiological findings. 99mTc glucarate showed avid concentration of tracer in the tumor, suggesting it to be a potential tumor imaging agent which can be used for detection and assessment of therapeutic response in malignancy. PMID:23372437

  17. Quantum Key Distribution Using Polarized Single Photons

    DTIC Science & Technology

    2009-04-01

    liquid helium the SSPD with a low - noise , cryogenic high-electron-mobility transistor (HEMT) with high-input impedance. This arrangement allowed us...Sobolewski, IEEE Trans. Appl. Supercon., accepted (2009). 19. " Measurements of amplitude distributions of dark counts and photon counts in NbN ...75, 174507 (2007). 6. "Fiber-Coupled NbN Superconducting Single-Photon Detectors for Quantum Correlation Measurements ," W. Slysz, M. Wegrzecki, J

  18. Single-photon counting multicolor multiphoton fluorescence microscope.

    PubMed

    Buehler, Christof; Kim, Ki H; Greuter, Urs; Schlumpf, Nick; So, Peter T C

    2005-01-01

    We present a multicolor multiphoton fluorescence microscope with single-photon counting sensitivity. The system integrates a standard multiphoton fluorescence microscope, an optical grating spectrograph operating in the UV-Vis wavelength region, and a 16-anode photomultiplier tube (PMT). The major technical innovation is in the development of a multichannel photon counting card (mC-PhCC) for direct signal collection from multi-anode PMTs. The electronic design of the mC-PhCC employs a high-throughput, fully-parallel, single-photon counting scheme along with a high-speed electrical or fiber-optical link interface to the data acquisition computer. There is no electronic crosstalk among the detection channels of the mC-PhCC. The collected signal remains linear up to an incident photon rate of 10(8) counts per second. The high-speed data interface offers ample bandwidth for real-time readout: 2 MByte lambda-stacks composed of 16 spectral channels, 256 x 256 pixel image with 12-bit dynamic range can be transferred at 30 frames per second. The modular design of the mC-PhCC can be readily extended to accommodate PMTs of more anodes. Data acquisition from a 64-anode PMT has been verified. As a demonstration of system performance, spectrally resolved images of fluorescent latex spheres and ex-vivo human skin are reported. The multicolor multiphoton microscope is suitable for highly sensitive, real-time, spectrally-resolved three-dimensional imaging in biomedical applications.

  19. Diagnosis of Pediatric Hyperthyroidism: Technetium 99 Uptake Versus Thyroid Stimulating Immunoglobulins

    PubMed Central

    Misra, Madhusmita; Levitsky, Lynne L.

    2015-01-01

    Background: Treatment with antithyroid drugs is effective in conditions of increased thyroid hormone production (mostly Graves' Disease; GD), but not in subacute thyroiditis (SAT) or autoimmune thyroiditis (AIT). Positive thyroid stimulating immunoglobulins (TSI) make GD likely. However, not all children with GD have increased TSI. Uptake studies with 123I or 99Tc (99mTc) provide accurate and rapid diagnosis but are expensive and involve radiation exposure. Our objective was to compare TSI with 99mTc uptake for diagnosis of pediatric hyperthyroidism. Methods: We performed a retrospective chart review of hyperthyroid children who had both TSI estimation and 99mTc uptake assessment at presentation. Based on subsequent laboratory studies and follow-up, 37 had GD and 10 had non-GD thyroiditis. The TSI index was considered positive (TSI+) when it was above the upper limit of normal. 99mTc uptake was considered positive (Tc+) for any uptake >0.4% and negative (and low) (Tc-) for uptake ≤0.4%. Results: Forty-seven youth (83% females), aged 12.3±4.6 years, presented with a suppressed thyrotropin (TSH) and elevated free thyroxine and total triiodothyronine. All 37 patients with GD were Tc+ (100% sensitivity and specificity). The sensitivity of TSI for diagnosing GD was 84%, and the specificity was 100%. Six patients with GD were discordant with Tc+ but TSI–. Elevated TSI correlated with Tc+ (p=0.01) with a degree of agreement (kappa) of 0.69. Conclusion: 99mTc has excellent specificity and sensitivity in diagnosing GD. Given additional costs of 99mTc (two and a half times as much as TSI), it is reasonable to reserve 99mTc uptake assessment for hyperthyroidism of unclear etiology and negative TSI. PMID:25257665

  20. Diagnosis of pediatric hyperthyroidism: technetium 99 uptake versus thyroid stimulating immunoglobulins.

    PubMed

    Baskaran, Charumathi; Misra, Madhusmita; Levitsky, Lynne L

    2015-01-01

    Treatment with antithyroid drugs is effective in conditions of increased thyroid hormone production (mostly Graves' Disease; GD), but not in subacute thyroiditis (SAT) or autoimmune thyroiditis (AIT). Positive thyroid stimulating immunoglobulins (TSI) make GD likely. However, not all children with GD have increased TSI. Uptake studies with (123)I or (99)Tc ((99m)Tc) provide accurate and rapid diagnosis but are expensive and involve radiation exposure. Our objective was to compare TSI with (99m)Tc uptake for diagnosis of pediatric hyperthyroidism. We performed a retrospective chart review of hyperthyroid children who had both TSI estimation and (99m)Tc uptake assessment at presentation. Based on subsequent laboratory studies and follow-up, 37 had GD and 10 had non-GD thyroiditis. The TSI index was considered positive (TSI+) when it was above the upper limit of normal. (99m)Tc uptake was considered positive (Tc+) for any uptake >0.4% and negative (and low) (Tc-) for uptake ≤0.4%. Forty-seven youth (83% females), aged 12.3±4.6 years, presented with a suppressed thyrotropin (TSH) and elevated free thyroxine and total triiodothyronine. All 37 patients with GD were Tc+ (100% sensitivity and specificity). The sensitivity of TSI for diagnosing GD was 84%, and the specificity was 100%. Six patients with GD were discordant with Tc+ but TSI-. Elevated TSI correlated with Tc+ (p=0.01) with a degree of agreement (kappa) of 0.69. (99m)Tc has excellent specificity and sensitivity in diagnosing GD. Given additional costs of (99m)Tc (two and a half times as much as TSI), it is reasonable to reserve (99m)Tc uptake assessment for hyperthyroidism of unclear etiology and negative TSI.

  1. QUANTUM CRYPTOGRAPHY: Single Photons.

    PubMed

    Benjamin, S

    2000-12-22

    Quantum cryptography offers the potential of totally secure transfer of information, but as Benjamin discusses in this Perspective, its practical implementation hinges on being able to generate single photons (rather than two or more) at a time. Michler et al. show how this condition can be met in a quantum dot microdisk structure. Single molecules were also recently shown to allow controlled single-photon emission.

  2. Use of {sup 99m}Tc 2-methoxyisobutyl isonitrile in minimally invasive radioguided surgery in patients with primary hyperparathyroidism: A narrative review of the current literature

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Denmeade, Kristie A; Constable, Chris; Reed, Warren M

    The use of technetium-99m 2-methoxyisobutyl isonitrile ({sup 99m}Tc MIBI) for assistance in minimally invasive radioguided surgery (MIRS) is growing in popularity as a safe, effective, and proficient technique used for parathyroidectomy in primary hyperparathyroidism (PHPT) treatment. Previously, the preferred treatment for PHPT was bilateral neck exploration (BNE), a very invasive, costly, and lengthy procedure. However, as a large majority (80–85% of cases of PHPT) are attributed to a single parathyroid adenoma (PA), a simpler more direct technique such as MIRS is a far better option. The following article is an exploration of the current literature concerning varied protocols utilizing {supmore » 99m}Tc MIBI for assistance in MIRS for patients undergoing treatment of PHPT. This technique boasts many advantageous outcomes for patients suffering from PHPT. These include a reduction in cost, operating time, and patient recovery; less evidence of post-surgical hypocalcaemia, less pain, and complications; superior cosmetic results; same-day discharge; and the possibility of local anaesthesia which is particularly beneficial in elderly patients. Better outcomes for patients with deep or ectopic PAs, reduced intra-operative complications, and improved cosmetic outcomes for patients who have previously undergone thyroid and/or parathyroid surgery are also advantageous. Of the literature reviewed it was also found that no patients suffered any major surgical complications such as laryngeal nerve palsy or permanent hypoparathyroidism using {sup 99m}Tc MIBI for assistance in MIRS.« less

  3. Brain perfusion abnormalities in Rett syndrome: a qualitative and quantitative SPET study with 99Tc(m)-ECD.

    PubMed

    Burroni, L; Aucone, A M; Volterrani, D; Hayek, Y; Bertelli, P; Vella, A; Zappella, M; Vattimo, A

    1997-06-01

    Rett syndrome is a progressive neurological paediatric disorder associated with severe mental deficiency, which affects only girls. The aim of this study was to determine if brain blood flow abnormalities detected with 99Tc(m)-ethyl-cysteinate-dimer (99Tc[m]-ECD) single photon emission tomography (SPET) can explain the clinical manifestation and progression of the disease. Qualitative and quantitative global and regional brain blood flow was evaluated in 12 girls with Rett syndrome and compared with an aged-matched reference group of children. In comparison with the reference group, SPET revealed a considerable global reduction in cerebral perfusion in the groups of girls with Rett syndrome. A large statistical difference was noted, which was more evident when comparing the control group with girls with stage IV Rett syndrome than girls with stage III Rett syndrome. The reduction in cerebral perfusion reflects functional disturbance in the brain of children with Rett syndrome. These data confirm that 99Tc(m)-ECD brain SPET is sensitive in detecting hypoperfused areas in girls with Rett syndrome that may be associated with brain atrophy, even when magnetic resonance imaging appears normal.

  4. Single-photon absorption by single photosynthetic light-harvesting complexes

    NASA Astrophysics Data System (ADS)

    Chan, Herman C. H.; Gamel, Omar E.; Fleming, Graham R.; Whaley, K. Birgitta

    2018-03-01

    We provide a unified theoretical approach to the quantum dynamics of absorption of single photons and subsequent excitonic energy transfer in photosynthetic light-harvesting complexes. Our analysis combines a continuous mode < n > -photon quantum optical master equation for the chromophoric system with the hierarchy of equations of motion describing excitonic dynamics in presence of non-Markovian coupling to vibrations of the chromophores and surrounding protein. We apply the approach to simulation of absorption of single-photon coherent states by pigment-protein complexes containing between one and seven chromophores, and compare with results obtained by excitation using a thermal radiation field. We show that the values of excitation probability obtained under single-photon absorption conditions can be consistently related to bulk absorption cross-sections. Analysis of the timescale and efficiency of single-photon absorption by light-harvesting systems within this full quantum description of pigment-protein dynamics coupled to a quantum radiation field reveals a non-trivial dependence of the excitation probability and the excited state dynamics induced by exciton-phonon coupling during and subsequent to the pulse, on the bandwidth of the incident photon pulse. For bandwidths equal to the spectral bandwidth of Chlorophyll a, our results yield an estimation of an average time of ˜0.09 s for a single chlorophyll chromophore to absorb the energy equivalent of one (single-polarization) photon under irradiation by single-photon states at the intensity of sunlight.

  5. Diversification of 99Mo/99mTc separation: non–fission reactor production of 99Mo as a strategy for enhancing 99mTc availability.

    PubMed

    Pillai, Maroor R A; Dash, Ashutosh; Knapp, Furn F Russ

    2015-01-01

    This paper discusses the benefits of obtaining (99m)Tc from non-fission reactor-produced low-specific-activity (99)Mo. This scenario is based on establishing a diversified chain of facilities for the distribution of (99m)Tc separated from reactor-produced (99)Mo by (n,γ) activation of natural or enriched Mo. Such facilities have expected lower investments than required for the proposed chain of cyclotrons for the production of (99m)Tc. Facilities can receive and process reactor-irradiated Mo targets then used for extraction of (99m)Tc over a period of 2 wk, with 3 extractions on the same day. Estimates suggest that a center receiving 1.85 TBq (50 Ci) of (99)Mo once every 4 d can provide 1.48-3.33 TBq (40-90 Ci) of (99m)Tc daily. This model can use research reactors operating in the United States to supply current (99)Mo needs by applying natural (nat)Mo targets. (99)Mo production capacity can be enhanced by using (98)Mo-enriched targets. The proposed model reduces the loss of (99)Mo by decay and avoids proliferation as well as waste management issues associated with fission-produced (99)Mo.

  6. Sentinel lymph node detection in early cervical cancer with combination 99mTc phytate and patent blue.

    PubMed

    Niikura, Hitoshi; Okamura, Chikako; Akahira, Junichi; Takano, Tadao; Ito, Kiyoshi; Okamura, Kunihiro; Yaegashi, Nobuo

    2004-08-01

    The purpose of this study was to examine sentinel lymph node (SLN) detection in patients with early stage cervical cancer using (99m)Tc phytate and patent blue dye and to compare our method with published findings utilizing other radioisotopic tracers. A total of 20 consecutive patients with cervical cancer scheduled for radical hysterectomy and total pelvic lymphadenectomy at our hospital underwent SLN detection study. The day before surgery, lymphoscintigraphy was performed with injection of 99m-technetium ((99m)Tc)-labeled phytate into the uterine cervix. At surgery, patients underwent lymphatic mapping with a gamma-detecting probe and patent blue injected into the same points as the phytate solution. At least one positive node was detected in 18 patients (90%). A total of 46 sentinel nodes were detected (mean, 2.3; range, 1-5). Most sentinel nodes were in one of the following sites: external iliac (21 nodes), obturator (15 nodes), and parametrial (7 nodes). Eleven (24%) sentinel nodes were detected only through radioactivity and two (4%) were detected only with blue dye. The sensitivity, specificity, and negative predictive value for SLN detection were all 100%. Nine published studies involving 295 patients had a summarized detection rate of 85%. Summarized sensitivity, specificity, and negative predictive value were 93%, 100%, and 99%, respectively. Combination of (99m)Tc phytate and patent blue is effective in SLN detection in early stage cervical cancer.

  7. Tunable room-temperature single-photon emission at telecom wavelengths from sp 3 defects in carbon nanotubes

    DOE PAGES

    He, Xiaowei; Hartmann, Nicolai F.; Ma, Xuedan; ...

    2017-07-31

    Generating quantum light emitters that operate at room temperature and at telecom wavelengths remains a significant materials challenge. To achieve this goal requires light sources that emit in the near-infrared wavelength region and that, ideally, are tunable to allow desired output wavelengths to be accessed in a controllable manner. Here, we show that exciton localization at covalently introduced aryl sp 3 defect sites in single-walled carbon nanotubes provides a route to room-temperature single-photon emission with ultrahigh single-photon purity (99%) and enhanced emission stability approaching the shot-noise limit. Moreover, we demonstrate that the inherent optical tunability of single-walled carbon nanotubes, presentmore » in their structural diversity, allows us to generate room-temperature single-photon emission spanning the entire telecom band. Furthermore, single-photon emission deep into the centre of the telecom C band (1.55 um) is achieved at the largest nanotube diameters we explore (0.936 nm).« less

  8. Tunable room-temperature single-photon emission at telecom wavelengths from sp 3 defects in carbon nanotubes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    He, Xiaowei; Hartmann, Nicolai F.; Ma, Xuedan

    Generating quantum light emitters that operate at room temperature and at telecom wavelengths remains a significant materials challenge. To achieve this goal requires light sources that emit in the near-infrared wavelength region and that, ideally, are tunable to allow desired output wavelengths to be accessed in a controllable manner. Here, we show that exciton localization at covalently introduced aryl sp 3 defect sites in single-walled carbon nanotubes provides a route to room-temperature single-photon emission with ultrahigh single-photon purity (99%) and enhanced emission stability approaching the shot-noise limit. Moreover, we demonstrate that the inherent optical tunability of single-walled carbon nanotubes, presentmore » in their structural diversity, allows us to generate room-temperature single-photon emission spanning the entire telecom band. Furthermore, single-photon emission deep into the centre of the telecom C band (1.55 um) is achieved at the largest nanotube diameters we explore (0.936 nm).« less

  9. Behavior of technetium-99 in soils and plants. Final report, April 1, 1974--December 31, 1978

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gast, R.G.; Landa, E.R.; Thorvig, L.J.

    Studies described in this report were aimed at establishing the magnitude and mechanisms of /sup 99/Tc sorption by soils and uptake by plants. Results show that /sup 99/Tc was sorbed from solution over a period to two to five weeks by 8 of 11 soils studies. The slow rate of sorption, the lack of sorption by low organic matter soils, the elimination of sorption following sterilization and increased sorption following addition of dextrose all point to a microbial role in the sorption process. However, it has not been established whether this is a direct or indirect role nor is itmore » possible to clearly predict the conditions under which sorption will occur. Results of plant uptake studies show that /sup 99/Tc can be taken up and translocated into the photosynthetic tissue of higher plants with concentrations in seeds being much less than in vegetative tissue. Technetium-99 was also shown to be toxic to plants at low concentrations and evidence suggests that this is a chemically rather than radiologically induced toxicity. However, this remains to be completely resolved as well as whether there is a threshold level of /sup 99/Tc required before toxicity occurs. Studies of short-term, dynamic, aerobic systems indicated that /sup 99/Tc moves through the soil as a relatively large anion exhibiting characteristic miscible displacement with some asymmetric tailing. /sup 99/Tc exhibits greater retention that C1/sup -/, which may be attributed statistically to weak complexion by organic matter. It is unlikely that this retention phenomenon is related to the static sorption activity reported in the first part of this study.« less

  10. APPLICATION OF FORMOHYDROXAMIC ACID IN NUCLEAR PROCESSING: SYNTHESIS AND COMPLEXATION WITH TECHNETIUM-99

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Amber Wright; Edward Mausolf; Keri Campbell

    2010-05-01

    Acetohydroxamic acid (AHA) is an organic ligand planned for use in the Uranium Extraction (UREX) process. It reduces neptunium and plutonium, and the resultant hydrophilic complexes are separated from uranium by extraction with tributyl phosphate (TBP) in a hydrocarbon diluent. AHA undergoes hydrolysis to acetic acid which will impede the recycling of nitric acid. During recent discussions of the UREX process, it has been proposed to replace AHA by formohydroxamic acid (FHA). FHA will undergo hydrolysis to formic acid which is volatile, thus allowing the recycling of nitric acid. The reported reduction potentials of AHA and pertechnetate (TcO{sub 4}{sup -})more » indicated that it may be possible for AHA to reduce technetium, altering its fate in the fuel cycle. At UNLV, it has been demonstrated that TcO{sub 4}{sup -} undergoes reductive nitrosylation by AHA under a variety of conditions. The resulting divalent technetium is complexed by AHA to form the pseudo-octahedral trans-aquonitrosyl (diacetohydroxamic)-technetium(II) complex ([Tc{sup II}(NO)(AHA){sub 2}H{sub 2}O]{sup +}). In this paper, we are reporting the synthesis of FHA and its complex formation with technetium along with the characterization of FHA crystals achieved by NMR and IR spectroscopy. Two experiments were conducted to investigate the complexation of FHA with Tc and the results were compared with previous data on AHA. The first experiment involved the elution of Tc from a Reillex HP anion exchange resin, and the second one monitored the complexation of technetium with FHA by UV-visible spectrophotometry.« less

  11. EVALUATION OF VADOSE ZONE TREATMENT TECHNOLOGIES TO IMMOBILIZE TECHNETIUM-99

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    PETERSEN, S.W.

    2006-03-15

    The Hanford Site End State Vision document (DOE/RL-2003-59) states: ''There should be an aggressive plan to develop technology for remediation of the contamination that could get to the groundwater (particularly the technetium [{sup 99}Tc])''. In addition, there is strong support from the public and regulatory agencies for the above statement, with emphasis on investigation of treatment alternatives. In July 2004, PNNL completed a preliminary evaluation of remediation technologies with respect to their effectiveness and implementability for immobilization of {sup 99}Tc beneath the BC Cribs in the 200 West Area (Truex, 2004). As a result of this evaluation, PNNL recommended treatabilitymore » testing of in situ soil desiccation, because it has the least uncertainty of those technologies evaluated in July 2004 (Treatability Test Outline, September 30, 2004). In 2005, DOE-RL and Fluor Hanford convened an independent technical panel to review alternative remediation technologies, including desiccation, at a three-day workshop in Richland, Washington. The panel was composed of experts in vadose-zone transport, infiltration control, hydrology, geochemistry, environmental engineering, and geology. Their backgrounds include employment in academia, government laboratories, industry, and consulting. Their review, presented in this document, is based upon written reports from Hanford, oral presentations from Hanford staff, and each panel members' years of experience in their particular field of expertise. The purpose of this report is to document the panel's evaluation of various treatment alternatives with potential for minimizing contaminant migration in the deep vadose zone at the Department of Energy Hanford Site. The panel was tasked with assessing the most viable and practical approach and making recommendations for testing. The evaluation of vadose-zone treatment alternatives was conducted to be broadly applicable at a variety of locations at Hanford. However

  12. Postoperative myocardial infarction documented by technetium pyrophosphate scan using single-photon emission computed tomography: Significance of intraoperative myocardial ischemia and hemodynamic control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cheng, D.C.; Chung, F.; Burns, R.J.

    The aim of this prospective study was to document postoperative myocardial infarction (PMI) by technetium pyrophosphate scan using single-photon emission computed tomography (TcPPi-SPECT) in 28 patients undergoing elective coronary bypass grafting (CABG). The relationships of intraoperative electrocardiographic myocardial ischemia, hemodynamic responses, and pharmacological requirements to this incidence of PMI were correlated. Radionuclide cardioangiography and TcPPi-SPECT were performed 24 h preoperatively and 48 h postoperatively. A standard high-dose fentanyl anesthetic protocol was used. Twenty-five percent of elective CABG patients were complicated with PMI, as documented by TcPPi-SPECT with an infarcted mass of 38.0 +/- 5.5 g. No significant difference in demographic,more » preoperative right and left ventricular function, number of coronary vessels grafted, or aortic cross-clamp time was observed between the PMI and non-PMI groups. The distribution of patients using preoperative beta-adrenergic blocking drugs or calcium channel blocking drugs was found to have no correlation with the outcome of PMI. As well, no significant differences in hemodynamic changes or pharmacological requirements were observed in the PMI and non-PMI groups during prebypass or postbypass periods, indicating careful intraoperative control of hemodynamic indices did not prevent the outcome of PMI in these patients. However, the incidence of prebypass ischemia was 39.3% and significantly correlated with the outcome of positive TcPPi-SPECT, denoting a 3.9-fold increased risk of developing PMI. Prebypass ischemic changes in leads II and V5 were shown to correlate with increased CPK-MB release (P less than 0.05) and tends to occur more frequently with lateral myocardial infarction.« less

  13. Non-pertechnetate Technetium Sensor Research and Development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bryan, Samuel A.; Rapko, Brian M.; Branch, Shirmir D.

    Several significant uncertainties remain regarding the understanding and modeling of the fate and speciation of technicium-99 ( 99Tc) in Hanford waste tanks, glass, and low-temperature waste forms. A significant (2% to 25%) fraction of the 99Tc in the water-soluble portion of the tank waste may be present as one or more non pertechnetate species that have not been identified and to date, cannot be effectively separated from the wastes. This task will provide a sensor specifically tuned to detect the Tc(I)-carbonyl species believed to constitute the main fraction of the non-pertechnetate form of technetium. By direct measurement of the non-pertechnetatemore » species, such a sensor will help reduce the uncertainties in the modeling of the fate and speciation of 99Tc in Hanford tanks and waste forms. This report summarizes work performed in FY2016 that was sponsored by the Department of Energy’s Office of Environmental Management and demonstrates the protocol for using fluorescent Tc(I)-tricarbonyl complex as a means to detect the non-pertechnetate species within tank waste solutions. The protocol was optimized with respect to ligand concentration, solvent choice, reaction temperature and time. This work culminated in the quantitation of Tc(I)-tricarbonyl within a waste simulant, using a standard addition method for measurement. This report also summarizes the synthesis and high-yield preparation of the low-valence technetium species, [Tc(CO) 3(H 2O) 3] +, which will be used as the technetium standard material for the demonstration of the non-pertechnetate species in actual wastes.« less

  14. Imaging study of using radiopharmaceuticals labeled with cyclotron-produced 99mTc.

    PubMed

    Hou, X; Tanguay, J; Vuckovic, M; Buckley, K; Schaffer, P; Bénard, F; Ruth, T J; Celler, A

    2016-12-07

    Cyclotron-produced 99m Tc (CPTc) has been recognized as an attractive and practical substitution of reactor/generator based 99m Tc. However, the small amount of 92-98 Mo in the irradiation of enriched 100 Mo could lead to the production of other radioactive technetium isotopes (Tc-impurities) which cannot be chemically separated. Thus, these impurities could contribute to patient dose and affect image quality. The potential radiation dose caused by these Tc-impurities produced using different targets, irradiation conditions, and corresponding to different injection times have been investigated, leading us to create dose-based limits of these parameters for producing clinically acceptable CPTc. However, image quality has been not considered. The aim of the present work is to provide a comprehensive and quantitative analysis of image quality for CPTc. The impact of Tc-impurities in CPTc on image resolution, background noise, and contrast is investigated by performing both Monte-Carlo simulations and phantom experiments. Various targets, irradiation, and acquisition conditions are employed for investigating the image-based limits of CPTc production parameters. Additionally, the relationship between patient dose and image quality of CPTc samples is studied. Only those samples which meet both dose- and image-based limits should be accepted in future clinical studies.

  15. Imaging study of using radiopharmaceuticals labeled with cyclotron-produced 99mTc

    NASA Astrophysics Data System (ADS)

    Hou, X.; Tanguay, J.; Vuckovic, M.; Buckley, K.; Schaffer, P.; Bénard, F.; Ruth, T. J.; Celler, A.

    2016-12-01

    Cyclotron-produced 99mTc (CPTc) has been recognized as an attractive and practical substitution of reactor/generator based 99mTc. However, the small amount of 92-98Mo in the irradiation of enriched 100Mo could lead to the production of other radioactive technetium isotopes (Tc-impurities) which cannot be chemically separated. Thus, these impurities could contribute to patient dose and affect image quality. The potential radiation dose caused by these Tc-impurities produced using different targets, irradiation conditions, and corresponding to different injection times have been investigated, leading us to create dose-based limits of these parameters for producing clinically acceptable CPTc. However, image quality has been not considered. The aim of the present work is to provide a comprehensive and quantitative analysis of image quality for CPTc. The impact of Tc-impurities in CPTc on image resolution, background noise, and contrast is investigated by performing both Monte-Carlo simulations and phantom experiments. Various targets, irradiation, and acquisition conditions are employed for investigating the image-based limits of CPTc production parameters. Additionally, the relationship between patient dose and image quality of CPTc samples is studied. Only those samples which meet both dose- and image-based limits should be accepted in future clinical studies.

  16. Interferometric Quantum-Nondemolition Single-Photon Detectors

    NASA Technical Reports Server (NTRS)

    Kok, Peter; Lee, Hwang; Dowling, Jonathan

    2007-01-01

    Two interferometric quantum-nondemolition (QND) devices have been proposed: (1) a polarization-independent device and (2) a polarization-preserving device. The prolarization-independent device works on an input state of up to two photons, whereas the polarization-preserving device works on a superposition of vacuum and single- photon states. The overall function of the device would be to probabilistically generate a unique detector output only when its input electromagnetic mode was populated by a single photon, in which case its output mode would also be populated by a single photon. Like other QND devices, the proposed devices are potentially useful for a variety of applications, including such areas of NASA interest as quantum computing, quantum communication, detection of gravity waves, as well as pedagogical demonstrations of the quantum nature of light. Many protocols in quantum computation and quantum communication require the possibility of detecting a photon without destroying it. The only prior single- photon-detecting QND device is based on quantum electrodynamics in a resonant cavity and, as such, it depends on the photon frequency. Moreover, the prior device can distinguish only between one photon and no photon. The proposed interferometric QND devices would not depend on frequency and could distinguish between (a) one photon and (b) zero or two photons. The first proposed device is depicted schematically in Figure 1. The input electromagnetic mode would be a superposition of a zero-, a one-, and a two-photon quantum state. The overall function of the device would be to probabilistically generate a unique detector output only when its input electromagnetic mode was populated by a single photon, in which case its output mode also would be populated by a single photon.

  17. Single-photon decision maker

    NASA Astrophysics Data System (ADS)

    Naruse, Makoto; Berthel, Martin; Drezet, Aurélien; Huant, Serge; Aono, Masashi; Hori, Hirokazu; Kim, Song-Ju

    2015-08-01

    Decision making is critical in our daily lives and for society in general and is finding evermore practical applications in information and communication technologies. Herein, we demonstrate experimentally that single photons can be used to make decisions in uncertain, dynamically changing environments. Using a nitrogen-vacancy in a nanodiamond as a single-photon source, we demonstrate the decision-making capability by solving the multi-armed bandit problem. This capability is directly and immediately associated with single-photon detection in the proposed architecture, leading to adequate and adaptive autonomous decision making. This study makes it possible to create systems that benefit from the quantum nature of light to perform practical and vital intelligent functions.

  18. Investigation of radioactivity concentration in spent technetium generators

    NASA Astrophysics Data System (ADS)

    Idriss, Hajo; Salih, Isam; Alaamer, Abdulaziz S.; Eisa, M. H.; Sam, A. K.

    2014-04-01

    This study was carried out to survey and measure radioactivity concentration and estimate radiation dose level at the surface of spent technetium generator columns for the safe final disposal of radioactive waste. High resolution γ-spectrometry with the aid of handheld radiation survey meters has been used. The radioactivity measurements has shown that 238U, 40K and 137Cs were only measurable in one sample whereas 125Sb was found in 14 samples out of total of 20 samples with an activity concentration which ranged from 21 to 7404 with an average value of 1095 Bq/kg. The activity concentration of 125Sb is highly variable indicating that the spent 99mTc generator columns are of different origin. This investigation highlighted the importance of radiation monitoring of spent technetium generators in the country in order to protect workers, and the public from the dangers posed by radioactive waste.

  19. Quantum optics. All-optical routing of single photons by a one-atom switch controlled by a single photon.

    PubMed

    Shomroni, Itay; Rosenblum, Serge; Lovsky, Yulia; Bechler, Orel; Guendelman, Gabriel; Dayan, Barak

    2014-08-22

    The prospect of quantum networks, in which quantum information is carried by single photons in photonic circuits, has long been the driving force behind the effort to achieve all-optical routing of single photons. We realized a single-photon-activated switch capable of routing a photon from any of its two inputs to any of its two outputs. Our device is based on a single atom coupled to a fiber-coupled, chip-based microresonator. A single reflected control photon toggles the switch from high reflection (R ~ 65%) to high transmission (T ~ 90%), with an average of ~1.5 control photons per switching event (~3, including linear losses). No additional control fields are required. The control and target photons are both in-fiber and practically identical, making this scheme compatible with scalable architectures for quantum information processing. Copyright © 2014, American Association for the Advancement of Science.

  20. Bone scanning in lymphoma. [/sup 99m/Tc tracer technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schechter, J.P.; Jones, S.E.; Woolfenden, J.M.

    1976-09-01

    The results of bone scanning with the newer technetium-99m complexes were correlated with clinical, laboratory, and radiographic findings in 26 patients with malignant lymphoma (10 with Hodgkin's disease and 16 with non-Hodgkin's lymphomas). Abnormalities on bone scan compatible with lymphomatous involvement of the skeleton appeared to occur more commonly in patients with diffuse lymphomas than in patients with nodular lymphomas and were generally observed in the setting of advanced disease (15 of 23 patients). Twenty-seven (73 percent) of the 37 scans obtained were abnormal. Although abnormal scans were observed with the greatest frequency in patients with bone pain (11 ofmore » 11), bone marrow involvement (11 of 12), abnormal skeletal radiographs (11 of 11), and elevated serum alkaline phosphatase levels (5 of 6), bone scanning also detected lymphomatous involvement in patients free of pain or with normal laboratory tests. Moreover, conventional radiography was entirely normal in six (35 percent) of 17 patients with abnormal scans and revealed only nonspecific osteopenia in another two patients (12 percent). Serial bone scans in nine patients reflected their response to chemotherapy. Of the 37 scans, only one was judged falsely positive and one falsely negative. Bone scanning with /sup 99m/Tc complexes is a safe, simple, and sensitive screening procedure for detecting both extensive and focal lymphomatous involvement of the skeletal system and is a useful means of following such involvement in response to treatment.« less

  1. Quantum key distribution over 120 km using ultrahigh purity single-photon source and superconducting single-photon detectors.

    PubMed

    Takemoto, Kazuya; Nambu, Yoshihiro; Miyazawa, Toshiyuki; Sakuma, Yoshiki; Yamamoto, Tsuyoshi; Yorozu, Shinichi; Arakawa, Yasuhiko

    2015-09-25

    Advances in single-photon sources (SPSs) and single-photon detectors (SPDs) promise unique applications in the field of quantum information technology. In this paper, we report long-distance quantum key distribution (QKD) by using state-of-the-art devices: a quantum-dot SPS (QD SPS) emitting a photon in the telecom band of 1.5 μm and a superconducting nanowire SPD (SNSPD). At the distance of 100 km, we obtained the maximal secure key rate of 27.6 bps without using decoy states, which is at least threefold larger than the rate obtained in the previously reported 50-km-long QKD experiment. We also succeeded in transmitting secure keys at the rate of 0.307 bps over 120 km. This is the longest QKD distance yet reported by using known true SPSs. The ultralow multiphoton emissions of our SPS and ultralow dark count of the SNSPD contributed to this result. The experimental results demonstrate the potential applicability of QD SPSs to practical telecom QKD networks.

  2. High-performance semiconductor quantum-dot single-photon sources

    NASA Astrophysics Data System (ADS)

    Senellart, Pascale; Solomon, Glenn; White, Andrew

    2017-11-01

    Single photons are a fundamental element of most quantum optical technologies. The ideal single-photon source is an on-demand, deterministic, single-photon source delivering light pulses in a well-defined polarization and spatiotemporal mode, and containing exactly one photon. In addition, for many applications, there is a quantum advantage if the single photons are indistinguishable in all their degrees of freedom. Single-photon sources based on parametric down-conversion are currently used, and while excellent in many ways, scaling to large quantum optical systems remains challenging. In 2000, semiconductor quantum dots were shown to emit single photons, opening a path towards integrated single-photon sources. Here, we review the progress achieved in the past few years, and discuss remaining challenges. The latest quantum dot-based single-photon sources are edging closer to the ideal single-photon source, and have opened new possibilities for quantum technologies.

  3. Synthesis and Evaluation of Technetium-99m- and Rhenium-Labeled Inhibitors of the Prostate-Specific Membrane Antigen (PSMA)

    PubMed Central

    Banerjee, Sangeeta R.; Foss, Catherine A.; Castanares, Mark; Mease, Ronnie C.; Byun, Youngjoo; Fox, James J.; Hilton, John; Lupold, Shawn E.; Kozikowski, Alan P.; Pomper, Martin G.

    2012-01-01

    The prostate-specific membrane antigen (PSMA) is increasingly recognized as a viable target for imaging and therapy of cancer. We prepared seven 99mTc/Re-labeled compounds by attaching known Tc/Re chelating agents to an amino-functionalized PSMA inhibitor (lys-NHCONH-glu) with or without a variable length linker moiety. Ki values ranged from 0.17 to 199 nM. Ex vivo biodistribution and in vivo imaging demonstrated the degree of specific binding to engineered PSMA+ PC3 PIP tumors. PC3-PIP cells are derived from PC3 that have been transduced with the gene for PSMA. Despite demonstrating nearly the lowest PSMA inhibitory potency of this series, [99mTc(CO)3(L1)]+ (L1 = (2-pyridylmethyl)2N(CH2)4CH(CO2H)-NHCO-(CH2)6CO-NH-lys-NHCONH-glu) showed the highest, most selective PIP tumor uptake, at 7.9 ± 4.0% injected dose per gram of tissue at 30 min postinjection. Radioactivity cleared from nontarget tissues to produce a PIP to flu (PSMA-PC3) ratio of 44:1 at 120 min postinjection. PSMA can accommodate the steric requirements of 99mTc/Re complexes within PSMA inhibitors, the best results achieved with a linker moiety between the ε amine of the urea lysine and the chelator. PMID:18637669

  4. Effect of increased surface tension and assisted ventilation on /sup 99m/Tc-DTPA clearance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jefferies, A.L.; Kawano, T.; Mori, S.

    1988-02-01

    Experiments were performed to determine the effects of conventional mechanical ventilation (CMV) and high-frequency oscillation (HFO) on the clearance of technetium-99m-labeled diethylenetriamine pentaacetate (/sup 99m/Tc-DTPA) from lungs with altered surface tension properties. A submicronic aerosol of /sup 99m/Tc-DTPA was insufflated into the lungs of anesthetized, tracheotomized rabbits before and 1 h after the administration of the aerosolized detergent dioctyl sodium sulfosuccinate (OT). Rabbits were ventilated by one of four methods: 1) spontaneous breathing; 2) CMV at 12 cmH2O mean airway pressure (MAP); 3) HFO at 12 cmH2O MAP; 4) HFO at 16 cmH2O MAP. Administration of OT resulted in decreasedmore » arterial PO2 (PaO2), increased lung wet-to-dry weight ratios, and abnormal lung pressure-volume relationships, compatible with increased surface tension. /sup 99m/Tc-DTPA clearance was accelerated after OT in all groups. The post-OT rate of clearance (k) was significantly faster (P less than 0.05) in the CMV at 12 cmH2O MAP (k = 7.57 +/- 0.71%/min (SE)) and HFO at 16 cmH2O MAP (k = 6.92 +/- 0.61%/min) groups than in the spontaneously breathing (k = 4.32 +/- 0.55%/min) and HFO at 12 cmH2O MAP (4.68 +/- 0.63%/min) groups. The clearance curves were biexponential in the former two groups. We conclude that pulmonary clearance of /sup 99m/Tc-DTPA is accelerated in high surface tension pulmonary edema, and this effect is enhanced by both conventional ventilation and HFO at high mean airway pressure.« less

  5. Time-resolved scattering of a single photon by a single atom

    PubMed Central

    Leong, Victor; Seidler, Mathias Alexander; Steiner, Matthias; Cerè, Alessandro; Kurtsiefer, Christian

    2016-01-01

    Scattering of light by matter has been studied extensively in the past. Yet, the most fundamental process, the scattering of a single photon by a single atom, is largely unexplored. One prominent prediction of quantum optics is the deterministic absorption of a travelling photon by a single atom, provided the photon waveform matches spatially and temporally the time-reversed version of a spontaneously emitted photon. Here we experimentally address this prediction and investigate the influence of the photon's temporal profile on the scattering dynamics using a single trapped atom and heralded single photons. In a time-resolved measurement of atomic excitation we find a 56(11)% increase of the peak excitation by photons with an exponentially rising profile compared with a decaying one. However, the overall scattering probability remains unchanged within the experimental uncertainties. Our results demonstrate that envelope tailoring of single photons enables precise control of the photon–atom interaction. PMID:27897173

  6. Bombesin receptors and transplanted stem cells in rat brain: High-resolution scan with 99mTc BN1.1

    NASA Astrophysics Data System (ADS)

    Scopinaro, F.; Paschali, E.; Di Santo, G.; Antonellis, T.; Massari, R.; Trotta, C.; Gourni, H.; Bouziotis, P.; David, V.; Soluri, A.; Varvarigou, A. D.

    2006-12-01

    The aim of this work is to detect the presence of transplanted stem cells (TSC) in rat brain with high-resolution (HR) scintigraphy and labelled bombesin (BN). BN is a morphogen for Central Nervous System (CNS) as well as for other organs: CNS-oriented TSC over-express BN Receptors (BNR). BN is also a neurotransmitter and modulates several functions of CNS. 99mTc labelled BN-like peptide scan of CNS is the ideal method to detect growing TSC once knowing normal distribution of BNRs in CNS. HR Planar and single photon emission computerized tomography (SPECT) images of rat brain were performed with new HR detectors (Li-tech, Italy). Pertechnetate, 99mTc HMPAO and the new 99mTc BN1.1 (patented) were i.v. administered in five rats. HR SPECT of 99mTc BN1.1 detected olfactory tract, fronto-lateral cortex, cerebellum, basal ganglia and amygdale. Results of SPECT were confirmed by bio-distribution study performed after autopsy of three of the five rats. The remaining two rats underwent cerebral lesions followed by transplant of TSC. Three months later, HR scintigraphy was repeated and showed images completely different from previous basal study, with hot spot of 99mTc BN1.1 corresponding to the site of TSC transplant. Immuno-histochemistry confirmed the presence of viable TSC. Not only 99mTc BN1.1 HR scan showed viability of transplanted TSC but also the "background brain" was the still now unknown map of BNR in mammalian brain.

  7. Generation of Single Photons and Entangled Photon Pairs from a Quantum Dot

    NASA Astrophysics Data System (ADS)

    Yamamoto, Y.; Pelton, M.; Santori, C.; Solomon, G. S.

    2002-10-01

    Current quantum cryptography systems are limited by the Poissonian photon statistics of a standard light source: a security loophole is opened up by the possibility of multiple-photon pulses. By replacing the source with a single-photon emitter, transmission rates of secure information can be improved. A single photon source is also essential to implement a linear optics quantum computer. We have investigated the use of single self-assembled InAs/GaAs quantum dots as such single-photon sources, and have seen a hundred-fold reduction in the multi-photon probability as compared to Poissonian pulses. An extension of our experiment should also allow for the generation of triggered, polarizationentangled photon pairs.

  8. Effect of different thickness of material filter on Tc-99m spectra and performance parameters of gamma camera

    NASA Astrophysics Data System (ADS)

    Nazifah, A.; Norhanna, S.; Shah, S. I.; Zakaria, A.

    2014-11-01

    This study aimed to investigate the effects of material filter technique on Tc-99m spectra and performance parameters of Philip ADAC forte dual head gamma camera. Thickness of material filter was selected on the basis of percentage attenuation of various gamma ray energies by different thicknesses of zinc material. A cylindrical source tank of NEMA single photon emission computed tomography (SPECT) Triple Line Source Phantom filled with water and Tc-99m radionuclide injected was used for spectra, uniformity and sensitivity measurements. Vinyl plastic tube was used as a line source for spatial resolution. Images for uniformity were reconstructed by filtered back projection method. Butterworth filter of order 5 and cut off frequency 0.35 cycles/cm was selected. Chang's attenuation correction method was applied by selecting 0.13/cm linear attenuation coefficient. Count rate was decreased with material filter from the compton region of Tc-99m energy spectrum, also from the photopeak region. Spatial resolution was improved. However, uniformity of tomographic image was equivocal, and system volume sensitivity was reduced by material filter. Material filter improved system's spatial resolution. Therefore, the technique may be used for phantom studies to improve the image quality.

  9. Myocardial perfusion imaging with technetium-99m SQ30217: Comparison with thallium-201 and coronary anatomy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seldin, D.W.; Johnson, L.L.; Blood, D.K.

    1989-03-01

    Myocardial perfusion in ten normal volunteers and 20 patients with coronary artery disease documented by recent coronary arteriography was studied with 99mTc-labeled SQ30217 and /sup 201/TI. Plantar /sup 201/TI imaging followed standard treadmill exercise and planar SQ30217 imaging followed upright bicycle exercise, performed to angina, or the same double product achieved on the treadmill test. Upright anterior, 30 degrees left anterior oblique, and 60 degrees left anterior oblique images were obtained for 3, 6, and 9 min, respectively, starting 2 min after injection of 15 mCi of 99mTc SQ30217. A second 15-mCi dose was injected at rest approximately 2 hrmore » later, and the same imaging protocol was followed. No adverse reactions or laboratory abnormalities attributable to SQ30217 were observed. All scans on the normal volunteers were interpreted as normal. Qualitative readings of both tests were equally sensitive for detecting patients with coronary disease (SQ30217 - 16/20, TI - 17/20, p = NS) and identifying abnormal vessels (SQ30217 - 19/45, TI - 21/45, p = NS). Both agents were falsely positive in 1/15 vessels. Ten vascular regions showed persistent abnormalities on resting SQ30217 scans; eight of these were distal to stenoses of at least 90% and three were also abnormal on thallium redistribution images. Hepatic uptake of SQ30217 obscured inferoapical segments in some views in 14/20 patients but did not interfere with abnormal vessel identification.« less

  10. Entanglement of remote material qubits through nonexciting interaction with single photons

    NASA Astrophysics Data System (ADS)

    Li, Gang; Zhang, Pengfei; Zhang, Tiancai

    2018-05-01

    We propose a scheme to entangle multiple material qubits through interaction with single photons via nonexciting processes associated with strongly coupling systems. The basic idea is based on the material state dependent reflection and transmission for the input photons. Thus, the material qubits in several systems can be entangled when one photon interacts with each system in cascade and the photon paths are mixed by the photon detection. The character of nonexciting of material qubits does not change the state of the material qubit and thus ensures the possibility of purifying entangled states by using more photons under realistic imperfect parameters. It also guarantees directly scaling up the scheme to entangle more qubits. Detailed analysis of fidelity and success probability of the scheme in the frame of an optical Fabry-Pérot cavity based strongly coupling system is presented. It is shown that a two-qubit entangled state with fidelity above 0.99 is promised with only two photons by using currently feasible experimental parameters. Our scheme can also be directly implemented on other strongly coupled system.

  11. Screening for Hepatopulmonary Syndrome in Cirrhotic Patients Using Technetium 99m-macroaggregated Albumin Perfusion Lung Scan (Tc-MAA): Diagnostic Approach and Clinical Correlations.

    PubMed

    Fragaki, Maria; Sifaki-Pistolla, Dimitra; Samonakis, Dimitrios N; Koulentaki, Mairi; Koukouraki, Sofia; Stathaki, Maria; Kouroumalis, Elias

    2017-09-28

    The aims of this study were to prospectively screen cirrhotic patients with arterial blood gas test and albumin perfusion scan, identify those fulfilling the classic hepatopulmonary syndrome (HPS) criteria, correlate with clinical parameters, and evaluate the survival of patients with HPS compared with those without HPS in a genetically homogenous Cretan cirrhotic population. Data on consecutive 102 patients within 1 year were collected and analyzed. All patients underwent a technetium 99m-macroaggregated albumin perfusion lung scan (Tc-MAA). Diagnosis of HPS was based on the presence of the quantitative index Tc-MAA≥6% and a [P(A-a)O2]≥15 mm Hg (≥20 mm Hg for patients over >64 y). In 94/102 patients, complete scintigraphic data were available. In total, 24 (26%) patients fulfilled the diagnostic criteria of HPS; 95.8% of them had mild-to-moderate HPS. In 8 patients the Tc-MAA scintigraphy could not be interpreted. There was no difference in HPS between decompensated (24.6%) and compensated cirrhosis (27.3%). In the multivariate analysis only the quantitative index was significant for the diagnosis of HPS (P=0.001, odds ratio; 95% confidence interval, 7.05; 2.27-21.87). Kaplan- Meier survival curves indicated a similar overall prognosis for patients diagnosed with HPS (P=0.105). HPS is a frequent complication of cirrhosis. Mild-to-moderate HPS has no significant effect on survival of cirrhotic patients. The quantitative Tc-MAA test is a reliable tool for diagnosis.

  12. Single-photon emitting diode in silicon carbide.

    PubMed

    Lohrmann, A; Iwamoto, N; Bodrog, Z; Castelletto, S; Ohshima, T; Karle, T J; Gali, A; Prawer, S; McCallum, J C; Johnson, B C

    2015-07-23

    Electrically driven single-photon emitting devices have immediate applications in quantum cryptography, quantum computation and single-photon metrology. Mature device fabrication protocols and the recent observations of single defect systems with quantum functionalities make silicon carbide an ideal material to build such devices. Here, we demonstrate the fabrication of bright single-photon emitting diodes. The electrically driven emitters display fully polarized output, superior photon statistics (with a count rate of >300 kHz) and stability in both continuous and pulsed modes, all at room temperature. The atomic origin of the single-photon source is proposed. These results provide a foundation for the large scale integration of single-photon sources into a broad range of applications, such as quantum cryptography or linear optics quantum computing.

  13. Lung clearance of /sup 99m/Tc-DTPA in patients with acute lung injury and pulmonary edema

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coates, G.; O'Brodovich, H.; Dolovich, M.

    1988-07-01

    Several acute and chronic conditions that alter the integrity of the pulmonary epithelium increased the rate of absorption or clearance into the circulation of small solutes deposited in the alveoli. Technetium 99m diethylenetriamine pentaacetic acid can be deposited in the lungs as a submicronic aerosol and its rate of clearance measured with a gamma camera or simple probe. This clearance technique is currently being used to evaluate patients who have developed pulmonary edema and also to detect those patients from a high risk group who are likely to develop adult respiratory distress syndrome (ARDS). Its role in the evaluation ofmore » patients with pulmonary edema is still under active investigation. It is clear that a single measurement in patients who smoke is not useful, but repeated measurements may provide important information. The lung clearance measurement is very sensitive to changes in epithelial integrity but is not specific for ARDS. It may be most useful in combination with other predictive tests or when the clearance rate is normal. 54 references.« less

  14. Targeting hypoxia in tumors using 2-nitroimidazoles with peptidic chelators for technetium-99m: effect of lipophilicity.

    PubMed

    Zhang, X; Su, Z F; Ballinger, J R; Rauth, A M; Pollak, A; Thornback, J R

    2000-01-01

    Tumor hypoxia is an important prognostic factor for response to therapy. Radiolabeled 2-nitroimidazoles have been used for imaging hypoxia, and the octanol/water partition coefficient (P) of these compounds appears to play a crucial role in their suitability for imaging. A series of 11 2-nitroimidazoles coupled to peptidic chelators for (99m)Tc with divergent P was developed and evaluated in an in vitro system. Two classes of N(3)S chelators were used: dialkyl-Gly-Ser-Cys-linker-2-nitroimidazole (Class I) and dialkyl-Gly-Lys(2-nitroimidazole)-Cys (Class II). The chelators were prepared by automated solid-phase peptide synthesis. Xanthine oxidase was able to reduce the 2-nitroimidiazole moiety on the ligands, but the rate of reduction varied 5-fold among the different chelators. The chelators were labeled by transchelation from [(99m)Tc]gluconate at temperatures between 22 and 100 degrees C. The reaction mixtures were analyzed by HPLC and their P values determined. The accumulation of each complex in suspension cultures of Chinese hamster ovary cells incubated under aerobic or extremely hypoxic conditions was determined. Radiochemical yields ranged from 5 to 80% for the 11 compounds. HPLC showed that some of the compounds formed two complexes with (99m)Tc, possibly syn and anti conformations with respect to the Tc=O bond. In general, the Class I chelators labeled more readily than the class II chelators. The P values of the (99m)Tc complexes varied from 0.0002 to 5 and were generally in accordance with predictions based on structure. There were also differences in P as a function of pH; the free acids had a lower P at pH 7.4 than at pH 2.0 due to ionization, whereas the amides did not show this effect. Accumulation levels in aerobic cells were related to P but varied over a narrow range. Four of the 11 compounds showed selective accumulation in hypoxic cells. The peptidic class of 2-nitroimidazoles, with flexible design and convenient solid-phase synthesis, deserves

  15. Rhenium Solubility in Borosilicate Nuclear Waste Glass: Implications for the Processing and Immobilization of Technetium-99

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCloy, John S.; Riley, Brian J.; Goel, Ashutosh

    2012-10-26

    The immobilization of 99Tc in a suitable host matrix has proved to be an arduous task for the researchers in nuclear waste community around the world. At the Hanford site in Washington State, the total amount of 99Tc in low-activity waste (LAW) is ~1300 kg and the current strategy is to immobilize the 99Tc in borosilicate glass with vitrification. In this context, the present article reports on the solubility/retention of rhenium, a nonradioactive surrogate for 99Tc, in a LAW borosilicate glass. Due to the radioactive nature of technetium, rhenium was chosen as a simulant because of the similarity between theirmore » ionic radii and other chemical aspects. The glasses containing Re (0 – 10,000 ppm by mass) were synthesized in vacuum-sealed quartz ampoules in order to minimize the loss of Re by volatilization during melting at 1000 °C. The rhenium was found to predominantly exist as Re (VII) in all the glasses as observed by X-ray absorption near-edge structure (XANES). The solubility of Re in borosilicate glasses was determined to be ~3000 ppm (by mass) with inductively coupled plasma-optical emission spectroscopy (ICP-OES). At higher rhenium concentrations, some additional material was retained in the glasses in the form of crystalline inclusions that were detected by X-ray diffraction (XRD) and laser ablation-ICP mass spectrometry (LA-ICP-MS). The implications of these results on the immobilization of 99Tc from radioactive wastes in borosilicate glasses have been discussed.« less

  16. Real-time myocardial perfusion imaging for pharmacologic stress testing: added value to single photon emission computed tomography.

    PubMed

    Korosoglou, Grigorios; Dubart, Alain-Eric; DaSilva, K Gaspar C; Labadze, Nino; Hardt, Stefan; Hansen, Alexander; Bekeredjian, Raffi; Zugck, Christian; Zehelein, Joerg; Katus, Hugo A; Kuecherer, Helmut

    2006-01-01

    Little is known about the incremental value of real-time myocardial contrast echocardiography (MCE) as an adjunct to pharmacologic stress testing. This study was performed to evaluate the diagnostic value of MCE to detect abnormal myocardial perfusion by technetium Tc 99m sestamibi-single photon emission computed tomography (SPECT) and anatomically significant coronary artery disease (CAD) by angiography. Myocardial contrast echocardiography was performed at rest and during vasodilator stress in consecutive patients (N = 120) undergoing SPECT imaging for known or suspected CAD. Myocardial opacification, wall motion, and tracer uptake were visually analyzed in 12 myocardial segments by 2 pairs of blinded observers. Concordance between the 2 methods was assessed using the kappa statistic. Of 1356 segments, 1025 (76%) were interpretable by MCE, wall motion, and SPECT. Sensitivity of wall motion was 75%, specificity 83%, and accuracy 81% for detecting abnormal myocardial perfusion by SPECT (kappa = 0.53). Myocardial contrast echocardiography and wall motion together yielded significantly higher sensitivity (85% vs 74%, P < .05), specificity of 83%, and accuracy of 85% (kappa = 0.64) for the detection of abnormal myocardial perfusion. In 89 patients who underwent coronary angiography, MCE and wall motion together yielded higher sensitivity (83% vs 64%, P < .05) and accuracy (77% vs 68%, P < .05) but similar specificity (72%) compared with SPECT for the detection of high-grade, stenotic (> or = 75%) coronary lesions. Assessment of myocardial perfusion adds value to conventional stress echocardiography by increasing its sensitivity for the detection of functionally abnormal myocardial perfusion. Myocardial contrast echocardiography and wall motion together provide higher sensitivity and accuracy for detection of CAD compared with SPECT.

  17. 99mTc-d,l-HMPAO and SPECT of the brain in normal aging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Waldemar, G.; Hasselbalch, S.G.; Andersen, A.R.

    1991-05-01

    Single photon emission computed tomography (SPECT) with 99mTc-d,l-hexamethylpropyleneamine oxime (99mTc-d,l-HMPAO) was used to determine global and regional CBF in 53 healthy subjects aged 21-83 years. For the whole group, global CBF normalized to the cerebellum was 86.4% +/- 8.4 (SD). The contribution of age, sex, and atrophy to variations in global CBF was studied using stepwise multiple regression analysis. There was a significant negative correlation of global CBF with subjective ratings of cortical atrophy, but not with ratings of ventricular size, Evans ratio, sex, or age. In a subgroup of 33 subjects, in whom volumetric measurements of atrophy were performed,more » cortical atrophy was the only significant determinant for global CBF, accounting for 27% of its variance. Mean global CBF as measured with the 133Xe inhalation technique and SPECT was 54 +/- 9 ml/100 g/min and did not correlate significantly with age. There was a preferential decline of CBF in the frontal cortex with advancing age. The side-to-side asymmetry of several regions of interest increased with age. A method was described for estimation of subcortical CBF, which decreased with advancing cortical atrophy. The relative area of the subcortical low-flow region increased with age. These results are useful in distinguishing the effects of age and simple atrophy from disease effects, when the 99mTc-d,l-HMPAO method is used.« less

  18. Photon pair source via two coupling single quantum emitters

    NASA Astrophysics Data System (ADS)

    Peng, Yong-Gang; Zheng, Yu-Jun

    2015-10-01

    We study the two coupling two-level single molecules driven by an external field as a photon pair source. The probability of emitting two photons, P2, is employed to describe the photon pair source quality in a short time, and the correlation coefficient RAB is employed to describe the photon pair source quality in a long time limit. The results demonstrate that the coupling single quantum emitters can be considered as a stable photon pair source. Project supported by the National Natural Science Foundation of China (Grand Nos. 91021009, 21073110, and 11374191), the Natural Science Foundation of Shandong Province, China (Grant No. ZR2013AQ020), the Postdoctoral Science Foundation of China (Grant No. 2013M531584), the Doctoral Program of Higher Education of China (Grant Nos. 20130131110005 and 20130131120006), and the Taishan Scholarship Project of Shandong Province, China.

  19. Comparison of americium-241 and technetium-99m as transmission sources for attenuation correction of thallium-201 SPECT imaging of the heart.

    PubMed

    Ficaro, E P; Fessler, J A; Rogers, W L; Schwaiger, M

    1994-04-01

    This study compares the ability of 241Am and 99mTc to estimate 201Tl attenuation maps while minimizing the loss in the precision of the emission data. A triple-head SPECT system with either an 241Am or 99mTc line source opposite a fan-beam collimator was used to estimate attenuation maps of the thorax of an anthropomorphic phantom. Linear attenuation values at 75 keV for 201Tl were obtained by linear extrapolation of the measured values from 241Am and 99mTc. Lung and soft-tissue estimates from both isotopes showed excellent agreement to within 3% of the measured values for 201Tl. Linear extrapolation did not yield satisfactory estimates for bone from either 241Am (+11.7%) or 99mTc (-15.3%). Patient data were used to estimate the dependence of crosstalk on patient size. Contamination from 201Tl in the transmission window was 5-6 times greater for 241Am compared to 99mTc, while the contamination in the 201Tl data in the transmission-emission detector head (head 1) was 4-5 times greater for 99mTc compared to 241Am. No contamination was detected in the 201Tl emission data of heads 2 and 3 from 241Am, whereas the 99mTc produced a small crosstalk component giving a signal-to-crosstalk ratio near 20:1. Measurements with a fillable chest phantom estimated the mean error introduced into the data from the removal of the crosstalk. Based on the measured data, 241Am is a suitable transmission source for simultaneous transmission-emission tomography for 201Tl cardiac studies.

  20. Spatially resolved assessment of hepatic function using 99mTc-IDA SPECT

    PubMed Central

    Wang, Hesheng; Cao, Yue

    2013-01-01

    Purpose: 99mTc-iminodiacetic acid (IDA) hepatobiliary imaging is usually quantified for hepatic function on the entire liver or regions of interest (ROIs) in the liver. The authors presented a method to estimate the hepatic extraction fraction (HEF) voxel-by-voxel from single-photon emission computed tomography (SPECT)/CT with a 99mTc-labeled IDA agent of mebrofenin and evaluated the spatially resolved HEF measurements with an independent physiological measurement. Methods: Fourteen patients with intrahepatic cancers were treated with radiation therapy (RT) and imaged by 99mTc-mebrofenin SPECT before and 1 month after RT. The dynamic SPECT volumes were with a resolution of 3.9 × 3.9 × 2.5 mm3. Throughout the whole liver with approximate 50 000 voxels, voxelwise HEF quantifications were estimated and compared between using arterial input function (AIF) from the heart and using vascular input function (VIF) from the spleen. The correlation between mean of the HEFs over the nontumor liver tissue and the overall liver function measured by Indocyanine green clearance half-time (T1/2) was assessed. Variation of the voxelwise estimation was evaluated in ROIs drawn in relatively homogeneous regions of the livers. The authors also examined effects of the time range parameter on the voxelwise HEF quantification. Results: Mean of the HEFs over the liver estimated using AIF significantly correlated with the physiological measurement T1/2 (r = 0.52, p = 0.0004), and the correlation was greatly improved by using VIF (r = 0.79, p < 0.0001). The parameter of time range for the retention phase did not lead to a significant difference in the means of the HEFs in the ROIs. Using VIF and a retention phase time range of 7–30 min, the relative variation of the voxelwise HEF in the ROIs was 10% ± 6% of respective mean HEF. Conclusions: The voxelwise HEF derived from 99mTc-IDA SPECT by the deconvolution analysis is feasible to assess the spatial distribution of hepatic function in

  1. Use of carbonated water in reduction of adjacent gastric activity in 456 consecutive technetium-99m myocardial perfusion imaging studies.

    PubMed

    Thomas, Dustin M; Lee, Joshua S; Charmforoush, Anthony; Rubal, Bernard J; Rosenblatt, Stephen A; Butler, Joshua T; Clemenshaw, Michael; Cheezum, Michael K; Slim, Ahmad M

    2015-12-01

    Small, observational trials have suggested a reduction in adjacent gastric activity with ingestion of soda water in myocardial perfusion imaging (MPI). We report our findings prior to and after implementation of soda water in 467 consecutive MPI studies. Consecutive MPI studies performed at a high-volume facility referred for vasodilator (VD) or exercise treadmill testing (ETT) were retrospectively reviewed before and after implementation of the soda water protocol. Patients undergoing the soda water protocol received 100 ml of soda water administered 30 min prior to image acquisition and after stress. Studies were performed using a same day rest/stress protocol. Incidence of adjacent gastric activity, diaphragmatic attenuation, stress and rest perfusion defects, and major adverse cardiovascular events (MACE) outcomes defined as death, myocardial infarction, stroke, reevaluation for chest pain, and late revascularization (>90 days from MPI) were abstracted using International Classification of Diseases, Ninth Revision (ICD-9) search. Two hundred and eighteen studies were performed prior to implementation of the soda water protocol and 249 studies were performed with the use of soda water. Baseline demographic data were equal between the groups with the exception of more patients undergoing VD stress receiving soda water (p < 0.001). Soda water was not associated with a decreased incidence of adjacent gastric activity with stress (54.7% versus 61.9% with no soda water, p = 0.129) or rest (68.6% versus 69.5% with no soda water, p = 0.919) imaging. Less adjacent gastric activity was observed with patients undergoing ETT who received soda water (42.5% versus 56.9% with no soda water, p = 0.031), but no difference was observed between the groups with VD stress (69.0% versus 68.1% with no soda water, p = 1.000). The use of soda water prior to technetium-99m MPI was associated with lower rates of adjacent gastric activity only in patients undergoing ETT stress but not

  2. The uptake by the canine tibia of the bone-scanning agent 99mTc-MDP before and after an osteotomy.

    PubMed

    Hughes, S; Khan, R; Davies, R; Lavender, P

    1978-11-01

    The residue and extraction of technetium-labelled methylene diphosphonate (99mTc-MDP), a substance used in bone scanning, was examined in the canine tibia and found to be low. Examination of washout curves suggested that there were four compartments in cortical bone, a vascular, a perivascular, a bone fluid and a bone compartment. After an osteotomy in the canine tibia the residue of 99mTc-MDP increased. This was believed to be due to an increase in the blood supply to the bone and to an associated increase in new bone available for exchange. Bone scanning in a fracture is therefore a reflection of the vascular status of the bone being examined and of the uptake by bone. This is dependent on there being an adequate blood supply to the bone and an increased number of mineral-binding sites.

  3. Single photon emission computed tomography and oth selected computer topics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frey, G.D.

    1981-07-01

    This book, the proceedings of a meeting in January 1980, contains 21 papers. Thirteen are devoted to aspects of emission tomography, four to nuclear cardiology, and five to other topics. The initial set of papers consists of reviews of the single photon emission tomography process. These include transverse axial tomography using scintillation cameras and other devices, longitudinal section tomography, and pin-hole and slant-hole systems. These reviews are generally well done, but as might be expected, lack any coherence from paper to paper. The papers on nuclear cardiology include several of Fourier analysis in nuclear cardiology and one on shunt quantification.more » Other clinical papers are on quantifying Tc-99m glucoheptonate uptake in the brain and on iron-59 retention studies. A general criticism of the book is the poor quality of photographic reproductions.« less

  4. Development of 99mTc-radiolabeled nanosilica for targeted detection of HER2-positive breast cancer

    PubMed Central

    Rainone, Paolo; Riva, Benedetta; Belloli, Sara; Sudati, Francesco; Ripamonti, Marilena; Verderio, Paolo; Colombo, Miriam; Colzani, Barbara; Gilardi, Maria Carla; Moresco, Rosa Maria; Prosperi, Davide

    2017-01-01

    The human epidermal growth factor receptor 2 (HER2) is normally associated with a highly aggressive and infiltrating phenotype in breast cancer lesions with propensity to spread into metastases. In clinic, the detection of HER2 in primary tumors and in their metastases is currently based on invasive methods. Recently, nuclear molecular imaging techniques, including positron emission tomography and single photon emission computed tomography (SPECT), allowed the detection of HER2 lesions in vivo. We have developed a 99mTc-radiolabeled nanosilica system, functionalized with a trastuzumab half-chain, able to act as drug carrier and SPECT radiotracer for the identification of HER2-positive breast cancer cells. To this aim, nanoparticles functionalized or not with trastuzumab half-chain, were radiolabeled using the 99mTc-tricarbonyl approach and evaluated in HER2 positive and negative breast cancer models. Cell uptake experiments, combined with flow cytometry and fluorescence imaging, suggested that active targeting provides higher efficiency and selectivity in tumor detection compared to passive diffusion, indicating that our radiolabeling strategy did not affect the nanoconjugate binding efficiency. Ex vivo biodistribution of 99mTc-nanosilica in a SK-BR-3 (HER2+) tumor xenograft at 4 h postinjection was higher in targeted compared to nontargeted nanosilica, confirming the in vitro data. In addition, viability and toxicity tests provided evidence on nanoparticle safety in cell cultures. Our results encourage further assessment of silica 99mTc-nanoconjugates to validate a safe and versatile nanoreporter system for both diagnosis and treatment of aggressive breast cancer. PMID:28496321

  5. TC-99 Decontaminant from heat treated gaseous diffusion membrane -Phase I, Part B

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oji, L.; Restivo, M.; Duignan, M.

    2017-11-01

    Uranium gaseous diffusion cascades represent a significant environmental challenge to dismantle, containerize and dispose as low-level radioactive waste. Baseline technologies rely on manual manipulations involving direct access to technetium-contaminated piping and materials. There is a potential to utilize novel decontamination technologies to remove the technetium and allow for on-site disposal of the very large uranium converters. Technetium entered these gaseous diffusion cascades as a hexafluoride complex in the same fashion as uranium. Technetium, as the isotope Tc-99, is an impurity that follows uranium in the first cycle of the Plutonium and Uranium Extraction (PUREX) process. The technetium speciation or exactmore » form in the gaseous diffusion cascades is not well defined. Several forms of Tc-99 compounds, mostly the fluorinated technetium compounds with varying degrees of volatility have been speculated by the scientific community to be present in these cascades. Therefore, there may be a possibility of using thermal or leaching desorption, which is independent of the technetium oxidation states, to perform an insitu removal of the technetium as a volatile species and trap the radionuclide on sorbent traps which could be disposed as low-level waste. Based on the positive results of the first part of this work1 the use of steam as a thermal decontamination agent was further explored with a second piece of used barrier material from a different location. This new series of tests included exposing more of the material surface to the flow of high temperature steam through the change in the reactor design, subjecting it to alternating periods of stream and vacuum, as well as determining if a lower temperature steam, i.e., 121°C (250°F) would be effective, too. Along with these methods, one other simpler method involving the leaching of the Tc-99 contaminated barrier material with a 1.0 M aqueous solution of ammonium carbonate, with and without

  6. Ibuprofen induces reduction of the proliferation-seeking radiotracer 99mTc-(V)DMSA uptake in severe epithelial breast hyperplasia without atypia.

    PubMed

    Papantoniou, Vassilios; Tsaroucha, Angeliki; Valsamaki, Pipitsa; Tsiouris, Spyridon; Sotiropoulou, Evangelia; Karianos, Theodore; Marinopoulos, Spyridon; Fothiadaki, Athina; Sotiropoulou, Maria; Archontaki, Aikaterini; Syrgiannis, Konstantinos; Dimitrakakis, Konstantinos; Antsaklis, Aris

    2010-10-01

    The purpose of this study was to investigate if ibuprofen intake can influence mammary uptake of the proliferation-seeking radiotracer technetium 99m-pentavalent dimercaptosuccinic acid (99mTc-(V)DMSA) in women with severe epithelial and atypical epithelial breast hyperplasia. Eight patients with histologically confirmed severe epithelial breast hyperplasia with (n  =  4) and without atypia (n  =  4) were submitted prospectively to 99mTc-(V)DMSA scintimammography before and after a 4-week course of 400 mg ibuprofen daily oral intake. Lesion to background ratios 60 minutes postinjection were calculated and compared (t-test) before and after ibuprofen administration. Prior to ibuprofen, the patients with severe epithelial hyperplasia displayed a significantly higher 99mTc-(V)DMSA uptake ratio compared to those with atypical epithelial hyperplasia (2.40 ± 0.32 vs 1.67 ± 0.09, respectively; p  =  .003). They also exhibited a more substantial percent decline in tracer uptake postibuprofen compared to women with atypical epithelial hyperplasia (62.0 ± 7.1 vs 15.0 ± 0.2, respectively; p  =  .001). Ibuprofen induces significant uptake reduction of the proliferation-seeking radiotracer 99mTc-(V)DMSA in severe epithelial breast hyperplasia without atypia. This agent could therefore constitute a potential imaging tool for monitoring chemoprophylaxis effectiveness in women at the early stages of malignant transformation.

  7. Downconversion quantum interface for a single quantum dot spin and 1550-nm single-photon channel.

    PubMed

    Pelc, Jason S; Yu, Leo; De Greve, Kristiaan; McMahon, Peter L; Natarajan, Chandra M; Esfandyarpour, Vahid; Maier, Sebastian; Schneider, Christian; Kamp, Martin; Höfling, Sven; Hadfield, Robert H; Forchel, Alfred; Yamamoto, Yoshihisa; Fejer, M M

    2012-12-03

    Long-distance quantum communication networks require appropriate interfaces between matter qubit-based nodes and low-loss photonic quantum channels. We implement a downconversion quantum interface, where the single photons emitted from a semiconductor quantum dot at 910 nm are downconverted to 1560 nm using a fiber-coupled periodically poled lithium niobate waveguide and a 2.2-μm pulsed pump laser. The single-photon character of the quantum dot emission is preserved during the downconversion process: we measure a cross-correlation g(2)(τ = 0) = 0.17 using resonant excitation of the quantum dot. We show that the downconversion interface is fully compatible with coherent optical control of the quantum dot electron spin through the observation of Rabi oscillations in the downconverted photon counts. These results represent a critical step towards a long-distance hybrid quantum network in which subsystems operating at different wavelengths are connected through quantum frequency conversion devices and 1.5-μm quantum channels.

  8. Viable myocardium scintigraphy with intravenous nitroglycerine by computed tomography with Tc-99m (MIBI).

    PubMed

    Ramos Filho, José; Nascimento, Marcos Welber; Silva, Rafael Mariano Gislon da; Camargo, Thiago Negrini de; Almeida, Roberto Simões de; Lima, Eloá Jacinto

    2008-09-01

    The selection of patients with chronic coronary disease for recanalization is based on the detection of the affected myocardium that is potentially viable. To evaluate the potentially viable ischemic myocardium through single photon emission computed tomography (SPECT) with MIBI after a maximum tolerated dose of I.V. nitroglycerin. We prospectively investigated by SPECT with Tc-99m (MIBI), from April 2004 to November 2005, 40 patients (mean age: 62 +/- 8.9 yrs, 30 men) with coronary obstruction demonstrated angiographically; the myocardium scintigraphy was carried out at rest and after intravenous (I.V.) nitroglycerin, which was started at a dose of 1 microg/kg/min and increased every minute until the systolic blood pressure decreased by 20 mmHg. The decrease in the perfusion of the segments was classified as moderate or severe and compared after the nitroglycerin. The angiographic, hemodynamic and myocardial perfusion variables were analyzed. We analyzed 680 myocardial segments at rest: 538 with a homogenous distribution and 142 with hypoperfusion (54 with moderate and 88 with severe decrease). After the nitroglycerin, there was an increase in the perfusion in 19 (47.5%) of 40 patients and 55 of 142 segments became viable: 33 (61.1%) with moderate and 22 (25%) with severe decrease; both presented a significant increase in the radiotracer distribution (p < 0.001, Chi-square). One of the components with Tc-99m is Tc-99m 2-methoxy-isobutyl-isonitrile (MIBI), which, when used with an optimized dose of I.V. nitroglycerin, can increase the radiotracer uptake in areas with moderate and severe hypoperfusion. The results of the present study suggest the increase in the Tc-99m (MIBI) sensitivity by nitroglycerin for the detection of viable myocardium.

  9. Solid-state single-photon emitters

    NASA Astrophysics Data System (ADS)

    Aharonovich, Igor; Englund, Dirk; Toth, Milos

    2016-10-01

    Single-photon emitters play an important role in many leading quantum technologies. There is still no 'ideal' on-demand single-photon emitter, but a plethora of promising material systems have been developed, and several have transitioned from proof-of-concept to engineering efforts with steadily improving performance. Here, we review recent progress in the race towards true single-photon emitters required for a range of quantum information processing applications. We focus on solid-state systems including quantum dots, defects in solids, two-dimensional hosts and carbon nanotubes, as these are well positioned to benefit from recent breakthroughs in nanofabrication and materials growth techniques. We consider the main challenges and key advantages of each platform, with a focus on scalable on-chip integration and fabrication of identical sources on photonic circuits.

  10. /sup 99m/Tc-fibrinogen scanning in adult respiratory distress syndrome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Quinn, D.A.; Carvalho, A.C.; Geller, E.

    1987-01-01

    Fibrin is often seen occluding the lung vessels of patients dying from ARDS and is surrounded by regions of lung necrosis. To learn if we could observe increased or focal fibrin deposition and assess the kinetics of plasma fibrinogen turnover during severe acute respiratory failure, we injected technetium 99m-labeled human purified fibrinogen (Tc-HF) and used gamma camera scanning for as long as 12 h in 13 sequential patients as soon as possible after ICU admission. The fibrinogen uptake rates were determined by calculating the lung:heart radioactivity ratios at each time point. Slopes of the lung:heart ratio versus time were comparedmore » between ARDS and mild acute respiratory failure (ARF). The slope of the lung:heart Tc-HF ratio of the 9 patients with ARDS (2.9 +/- 0.4 units) was markedly higher (p less than 0.02) than the slope of the 4 patients with mild ARF (1.1 +/- 0.4) and the 3 patients studied 5 to 9 months after recovery from respiratory failure (0.7 +/- 0.07). In the 1 patient with ARDS and the 2 patients with mild ARF studied both during acute lung injury and after recovery, the lung:heart Tc-HF ratio had decreased at recovery. To compare the pulmonary uptake of Tc-HF to /sup 99m/Tc-labeled human serum albumin (Tc-HSA), 5 patients were injected with 10 mCi of Tc-HSA, and scanning of the thorax was performed with a similar sequential imaging protocol 24 h after conclusion of the Tc-HF study.« less

  11. Cohesive Relations for Surface Atoms in the Iron-Technetium Binary System

    DOE PAGES

    Taylor, Christopher D.

    2011-01-01

    Iron-technetium alloys are of relevance to the development of waste forms for disposition of radioactive technetium-99 obtained from spent nuclear fuel. Corrosion of candidate waste forms is a function of the local cohesive energy () of surface atoms. A theoretical model for calculating is developed. Density functional theory was used to construct a modified embedded atom (MEAM) potential for iron-technetium. Materials properties determined for the iron-technetium system were in good agreement with the literature. To explore the relationship between local structure and corrosion, MEAM simulations were performed on representative iron-technetium alloys and intermetallics. Technetium-rich phases have lower , suggesting thatmore » these phases will be more noble than iron-rich ones. Quantitative estimates of based on numbers of nearest neighbors alone can lead to errors up to 0.5 eV. Consequently, atomistic corrosion simulations for alloy systems should utilize physics-based models that consider not only neighbor counts, but also local compositions and atomic arrangements.« less

  12. Generating single microwave photons in a circuit.

    PubMed

    Houck, A A; Schuster, D I; Gambetta, J M; Schreier, J A; Johnson, B R; Chow, J M; Frunzio, L; Majer, J; Devoret, M H; Girvin, S M; Schoelkopf, R J

    2007-09-20

    Microwaves have widespread use in classical communication technologies, from long-distance broadcasts to short-distance signals within a computer chip. Like all forms of light, microwaves, even those guided by the wires of an integrated circuit, consist of discrete photons. To enable quantum communication between distant parts of a quantum computer, the signals must also be quantum, consisting of single photons, for example. However, conventional sources can generate only classical light, not single photons. One way to realize a single-photon source is to collect the fluorescence of a single atom. Early experiments measured the quantum nature of continuous radiation, and further advances allowed triggered sources of photons on demand. To allow efficient photon collection, emitters are typically placed inside optical or microwave cavities, but these sources are difficult to employ for quantum communication on wires within an integrated circuit. Here we demonstrate an on-chip, on-demand single-photon source, where the microwave photons are injected into a wire with high efficiency and spectral purity. This is accomplished in a circuit quantum electrodynamics architecture, with a microwave transmission line cavity that enhances the spontaneous emission of a single superconducting qubit. When the qubit spontaneously emits, the generated photon acts as a flying qubit, transmitting the quantum information across a chip. We perform tomography of both the qubit and the emitted photons, clearly showing that both the quantum phase and amplitude are transferred during the emission. Both the average power and voltage of the photon source are characterized to verify performance of the system. This single-photon source is an important addition to a rapidly growing toolbox for quantum optics on a chip.

  13. Liquid scintillation counting methodology for 99Tc analysis. A remedy for radiopharmaceutical waste

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khan, Mumtaz; Um, Wooyong

    2015-08-13

    This paper presents a new approach for liquid scintillation counting (LSC) analysis of single-radionuclide samples containing appreciable organic or inorganic quench. This work offers better analytical results than existing LSC methods for technetium-99 ( 99gTc) analysis with significant savings in analysis cost and time. The method was developed to quantify 99gTc in environmental liquid and urine samples using LSC. Method efficiency was measured in the presence of 1.9 to 11,900 ppm total dissolved solids. The quench curve was proved to be effective in the case of spiked 99gTc activity calculation for deionized water, tap water, groundwater, seawater, and urine samples.more » Counting efficiency was found to be 91.66% for Ultima Gold LLT (ULG-LLT) and Ultima Gold (ULG). Relative error in spiked 99gTc samples was ±3.98% in ULG and ULG-LLT cocktails. Minimum detectable activity was determined to be 25.3 mBq and 22.7 mBq for ULG-LLT and ULG cocktails, respectively. A pre-concentration factor of 1000 was achieved at 100°C for 100% chemical recovery.« less

  14. In vivo click reaction between Tc-99m-labeled azadibenzocyclooctyne-MAMA and 2-nitroimidazole-azide for tumor hypoxia targeting.

    PubMed

    Sun, Wenjing; Chu, Taiwei

    2015-10-15

    The bioactivity of nitroimidazole in Tc-99m-labeled 2-nitroimidazole, a traditional solid tumor hypoxia-imaging agent for single photon emission computed tomography (SPECT), is reduced by the presence of large ligand and metallic radionuclide, exhibiting lower tumor-to-nontumor ratios. In an effort to solve this general problem, a pretargeting strategy based on click chemistry (strain-promoted cyclooctyne-azide cycloaddition) was applied. The functional click synthons were synthesized as pretargeting components: an azide group linked to 2-nitroimidazole (2NIM-Az) serves for tumor hypoxia-targeting and azadibenzocyclooctyne conjugated with monoamine monoamide dithiol ligand (AM) functions as radiolabeling and binding group to azides in vivo. 2NIM-triazole-MAMA was obtained from in vitro click reaction with a reaction rate constant of 0.98M(-1)s(-1). AM and 2NIM-triazole-MAMA were radiolabeled with Tc-99m. The hypoxia-pretargeting biodistribution was studied in Kunming mice bearing S180 tumor; (99m)Tc-AM and (99m)Tc-triazole-2NIM were used as blank control and conventional control. Compared to the control groups, the pretargeting experiment exhibits the best radio-uptake and retention in tumor, with higher tumor-to-muscle and tumor-to-blood ratios (up to 8.55 and 1.44 at 8h post-(99m)Tc-complex-injection, respectively). To some extent, the pretargeting strategy protects the bioactivity of nitroimidazole and therefore provides an innovative approach for the development of tumor hypoxia-SPECT imaging agents. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Highly specific preoperative selection of solitary parathyroid adenoma cases in primary hyperparathyroidism by quantitative image analysis of the early-phase Technetium-99m sestamibi scan.

    PubMed

    Kim, DaeHee; Rhodes, Jeffrey A; Hashim, Jeffrey A; Rickabaugh, Lawrence; Brams, David M; Pinkus, Edward; Dou, Yamin

    2018-06-07

    Highly specific preoperative localizing test is required to select patients for minimally invasive parathyroidectomy (MIP) in lieu of traditional four-gland exploration. We hypothesized that Tc-99m sestamibi scan interpretation incorporating numerical measurements on the degree of asymmetrical activity from bilateral thyroid beds can be useful in localizing single adenoma for MIP. We devised a quantitative interpretation method for Tc-99m sestamibi scan based on the numerically graded asymmetrical activity on early phase. The numerical ratio value of each scan was obtained by dividing the number of counts from symmetrically drawn regions of interest (ROI) over bilateral thyroid beds. The final pathology and clinical outcome of 109 patients were used to perform receiver operating curve (ROC) analysis. Receiver operating curve analysis revealed the area under the curve (AUC) was calculated to be 0.71 (P = 0.0032), validating this method as a diagnostic tool. The optimal cut-off point for the ratio value with maximal combined sensitivity and specificity was found with corresponding sensitivity of 67.9% (56.5-77.2%, 95% CI) and specificity of 75.0% (52.8-91.8%, 95% CI). An additional higher cut-off with higher specificity with minimal possible sacrifice on sensitivity was also selected, yielding sensitivity of 28.6% (18.8-38.6%, 95% CI) and specificity of 90.0% (69.6-98.8%, 95% CI). Our results demonstrated that the more asymmetrical activity on the initial phase, the more successful it is to localize a single parathyroid adenoma on sestamibi scans. Using early-phase Tc-99m sestamibi scan only, we were able to select patients for minimally invasive parathyroidectomy with 90% specificity. © 2018 The Royal Australian and New Zealand College of Radiologists.

  16. Single-photon imager based on a superconducting nanowire delay line

    NASA Astrophysics Data System (ADS)

    Zhao, Qing-Yuan; Zhu, Di; Calandri, Niccolò; Dane, Andrew E.; McCaughan, Adam N.; Bellei, Francesco; Wang, Hao-Zhu; Santavicca, Daniel F.; Berggren, Karl K.

    2017-03-01

    Detecting spatial and temporal information of individual photons is critical to applications in spectroscopy, communication, biological imaging, astronomical observation and quantum-information processing. Here we demonstrate a scalable single-photon imager using a single continuous superconducting nanowire that is not only a single-photon detector but also functions as an efficient microwave delay line. In this context, photon-detection pulses are guided in the nanowire and enable the readout of the position and time of photon-absorption events from the arrival times of the detection pulses at the nanowire's two ends. Experimentally, we slowed down the velocity of pulse propagation to ∼2% of the speed of light in free space. In a 19.7 mm long nanowire that meandered across an area of 286 × 193 μm2, we were able to resolve ∼590 effective pixels with a temporal resolution of 50 ps (full width at half maximum). The nanowire imager presents a scalable approach for high-resolution photon imaging in space and time.

  17. A stable wavelength-tunable triggered source of single photons and cascaded photon pairs at the telecom C-band

    NASA Astrophysics Data System (ADS)

    Zeuner, Katharina D.; Paul, Matthias; Lettner, Thomas; Reuterskiöld Hedlund, Carl; Schweickert, Lucas; Steinhauer, Stephan; Yang, Lily; Zichi, Julien; Hammar, Mattias; Jöns, Klaus D.; Zwiller, Val

    2018-04-01

    The implementation of fiber-based long-range quantum communication requires tunable sources of single photons at the telecom C-band. Stable and easy-to-implement wavelength-tunability of individual sources is crucial to (i) bring remote sources into resonance, (ii) define a wavelength standard, and (iii) ensure scalability to operate a quantum repeater. So far, the most promising sources for true, telecom single photons are semiconductor quantum dots, due to their ability to deterministically and reliably emit single and entangled photons. However, the required wavelength-tunability is hard to attain. Here, we show a stable wavelength-tunable quantum light source by integrating strain-released InAs quantum dots on piezoelectric substrates. We present triggered single-photon emission at 1.55 μm with a multi-photon emission probability as low as 0.097, as well as photon pair emission from the radiative biexciton-exciton cascade. We achieve a tuning range of 0.25 nm which will allow us to spectrally overlap remote quantum dots or tuning distant quantum dots into resonance with quantum memories. This opens up realistic avenues for the implementation of photonic quantum information processing applications at telecom wavelengths.

  18. Evaluation of new Tc-99m-labeled Arg-X-Asp-conjugated α-melanocyte stimulating hormone peptides for melanoma imaging.

    PubMed

    Flook, Adam M; Yang, Jianquan; Miao, Yubin

    2013-09-03

    The purpose of this study was to examine the melanoma targeting and imaging properties of two new (99m)Tc-labeled Arg-X-Asp-conjugated α-melanocyte stimulating hormone (α-MSH) peptides. RTD-Lys-(Arg(11))CCMSH {c[Asp-Arg-Thr-Asp-DTyr]-Lys-Cys-Cys-Glu-His-DPhe-Arg-Trp-Cys-Arg-Pro-Val-NH2} and RVD-Lys-(Arg(11))CCMSH peptides were synthesized, and their melanocortin-1 (MC1) receptor binding affinities were determined in B16/F1 melanoma cells. The biodistribution and melanoma imaging properties of (99m)Tc-RTD-Lys-(Arg(11))CCMSH and (99m)Tc-RVD-Lys-(Arg(11))CCMSH were determined in B16/F1 melanoma-bearing C57 mice. The IC50 values of RTD-Lys-(Arg(11))CCMSH and RVD-Lys-(Arg(11))CCMSH were 0.7 ± 0.07 and 1.0 ± 0.3 nM in B16/F1 melanoma cells. Both (99m)Tc-RTD-Lys-(Arg(11))CCMSH and (99m)Tc-RVD-Lys-(Arg(11))CCMSH displayed high melanoma uptake. (99m)Tc-RTD-Lys-(Arg(11))CCMSH exhibited the highest tumor uptake of 18.77 ± 5.13% ID/g at 2 h postinjection, whereas (99m)Tc-RVD-Lys-(Arg(11))CCMSH reached the highest tumor uptake of 19.63 ± 4.68% ID/g at 4 h postinjection. Both (99m)Tc-RTD-Lys-(Arg(11))CCMSH and (99m)Tc-RVD-Lys-(Arg(11))CCMSH showed low accumulation in normal organs (<1.7% ID/g) except for the kidneys at 2 h postinjection. The renal uptake of (99m)Tc-RTD-Lys-(Arg(11))CCMSH and (99m)Tc-RVD-Lys-(Arg(11))CCMSH was 135.14 ± 23.62 and 94.01 ± 18.31% ID/g at 2 h postinjection, respectively. The melanoma lesions were clearly visualized by single-photon emission computed tomography (SPECT)/CT using either (99m)Tc-RTD-Lys-(Arg(11))CCMSH or (99m)Tc-RVD-Lys-(Arg(11))CCMSH as an imaging probe at 2 h postinjection. Overall, the introduction of Thr or Val residue retained high melanoma uptake of (99m)Tc-RTD-Lys-(Arg(11))CCMSH and (99m)Tc-RVD-Lys-(Arg(11))CCMSH. However, high renal uptake of (99m)Tc-RTD-Lys-(Arg(11))CCMSH and (99m)Tc-RVD-Lys-(Arg(11))CCMSH need to be reduced to facilitate their future applications.

  19. Single meson production in photon-photon collisions and infrared renormalons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahmadov, A. I.; Department of Theoretical Physics, Baku State University, Z. Khalilov Street 23, AZ-1148, Baku; Aydin, Coskun

    2010-03-01

    In this article, we investigate the contribution of the higher-twist Feynman diagrams to the large-p{sub T} inclusive single meson production cross section in photon-photon collisions and present the general formulas for the higher-twist differential cross sections in case of the running coupling and frozen coupling approaches. The structure of infrared renormalon singularities of the higher-twist subprocess cross section and the resummed expression (the Borel sum) for it are found. We compared the resummed higher-twist cross sections with the ones obtained in the framework of the frozen coupling approach and leading-twist cross section. We obtain, that ratio R=({Sigma}{sub M}{sup +HT}){sup res}/({Sigma}{submore » M}{sup +HT}){sup 0}, for all values of the transverse momentum p{sub T} of the meson identically equivalent to ratio r=({Delta}{sub M}{sup HT}){sup res}/({Delta}{sub M}{sup HT}){sup 0}. It is shown that the resummed result depends on the choice of the meson wave functions used in calculation. Phenomenological effects of the obtained results are discussed.« less

  20. InGaAs/InAlAs single photon avalanche diode for 1550 nm photons.

    PubMed

    Meng, Xiao; Xie, Shiyu; Zhou, Xinxin; Calandri, Niccolò; Sanzaro, Mirko; Tosi, Alberto; Tan, Chee Hing; Ng, Jo Shien

    2016-03-01

    A single photon avalanche diode (SPAD) with an InGaAs absorption region, and an InAlAs avalanche region was designed and demonstrated to detect 1550 nm wavelength photons. The characterization included leakage current, dark count rate and single photon detection efficiency as functions of temperature from 210 to 294 K. The SPAD exhibited good temperature stability, with breakdown voltage dependence of approximately 45 mV K(-1). Operating at 210 K and in a gated mode, the SPAD achieved a photon detection probability of 26% at 1550 nm with a dark count rate of 1 × 10(8) Hz. The time response of the SPAD showed decreasing timing jitter (full width at half maximum) with increasing overbias voltage, with 70 ps being the smallest timing jitter measured.

  1. InGaAs/InAlAs single photon avalanche diode for 1550 nm photons

    PubMed Central

    Xie, Shiyu; Zhou, Xinxin; Calandri, Niccolò; Sanzaro, Mirko; Tosi, Alberto; Tan, Chee Hing; Ng, Jo Shien

    2016-01-01

    A single photon avalanche diode (SPAD) with an InGaAs absorption region, and an InAlAs avalanche region was designed and demonstrated to detect 1550 nm wavelength photons. The characterization included leakage current, dark count rate and single photon detection efficiency as functions of temperature from 210 to 294 K. The SPAD exhibited good temperature stability, with breakdown voltage dependence of approximately 45 mV K−1. Operating at 210 K and in a gated mode, the SPAD achieved a photon detection probability of 26% at 1550 nm with a dark count rate of 1 × 108 Hz. The time response of the SPAD showed decreasing timing jitter (full width at half maximum) with increasing overbias voltage, with 70 ps being the smallest timing jitter measured. PMID:27069647

  2. What are single photons good for?

    NASA Astrophysics Data System (ADS)

    Sangouard, Nicolas; Zbinden, Hugo

    2012-10-01

    In a long-held preconception, photons play a central role in present-day quantum technologies. But what are sources producing photons one by one good for precisely? Well, in opposition to what many suggest, we show that single-photon sources are not helpful for point to point quantum key distribution because faint laser pulses do the job comfortably. However, there is no doubt about the usefulness of sources producing single photons for future quantum technologies. In particular, we show how single-photon sources could become the seed of a revolution in the framework of quantum communication, making the security of quantum key distribution device-independent or extending quantum communication over many hundreds of kilometers. Hopefully, these promising applications will provide a guideline for researchers to develop more and more efficient sources, producing narrowband, pure and indistinguishable photons at appropriate wavelengths.

  3. Multimodality imaging using SPECT/CT and MRI and ligand functionalized 99mTc-labeled magnetic microbubbles

    PubMed Central

    2013-01-01

    Background In the present study, we used multimodal imaging to investigate biodistribution in rats after intravenous administration of a new 99mTc-labeled delivery system consisting of polymer-shelled microbubbles (MBs) functionalized with diethylenetriaminepentaacetic acid (DTPA), thiolated poly(methacrylic acid) (PMAA), chitosan, 1,4,7-triacyclononane-1,4,7-triacetic acid (NOTA), NOTA-super paramagnetic iron oxide nanoparticles (SPION), or DTPA-SPION. Methods Examinations utilizing planar dynamic scintigraphy and hybrid imaging were performed using a commercially available single-photon emission computed tomography (SPECT)/computed tomography (CT) system. For SPION containing MBs, the biodistribution pattern of 99mTc-labeled NOTA-SPION and DTPA-SPION MBs was investigated and co-registered using fusion SPECT/CT and magnetic resonance imaging (MRI). Moreover, to evaluate the biodistribution, organs were removed and radioactivity was measured and calculated as percentage of injected dose. Results SPECT/CT and MRI showed that the distribution of 99mTc-labeled ligand-functionalized MBs varied with the type of ligand as well as with the presence of SPION. The highest uptake was observed in the lungs 1 h post injection of 99mTc-labeled DTPA and chitosan MBs, while a similar distribution to the lungs and the liver was seen after the administration of PMAA MBs. The highest counts of 99mTc-labeled NOTA-SPION and DTPA-SPION MBs were observed in the lungs, liver, and kidneys 1 h post injection. The highest counts were observed in the liver, spleen, and kidneys as confirmed by MRI 24 h post injection. Furthermore, the results obtained from organ measurements were in good agreement with those obtained from SPECT/CT. Conclusions In conclusion, microbubbles functionalized by different ligands can be labeled with radiotracers and utilized for SPECT/CT imaging, while the incorporation of SPION in MB shells enables imaging using MR. Our investigation revealed that biodistribution

  4. Ultrafast single photon emitting quantum photonic structures based on a nano-obelisk.

    PubMed

    Kim, Je-Hyung; Ko, Young-Ho; Gong, Su-Hyun; Ko, Suk-Min; Cho, Yong-Hoon

    2013-01-01

    A key issue in a single photon source is fast and efficient generation of a single photon flux with high light extraction efficiency. Significant progress toward high-efficiency single photon sources has been demonstrated by semiconductor quantum dots, especially using narrow bandgap materials. Meanwhile, there are many obstacles, which restrict the use of wide bandgap semiconductor quantum dots as practical single photon sources in ultraviolet-visible region, despite offering free space communication and miniaturized quantum information circuits. Here we demonstrate a single InGaN quantum dot embedded in an obelisk-shaped GaN nanostructure. The nano-obelisk plays an important role in eliminating dislocations, increasing light extraction, and minimizing a built-in electric field. Based on the nano-obelisks, we observed nonconventional narrow quantum dot emission and positive biexciton binding energy, which are signatures of negligible built-in field in single InGaN quantum dots. This results in efficient and ultrafast single photon generation in the violet color region.

  5. Aerosol Delivery with Two Nebulizers Through High-Flow Nasal Cannula: A Randomized Cross-Over Single-Photon Emission Computed Tomography-Computed Tomography Study.

    PubMed

    Dugernier, Jonathan; Hesse, Michel; Jumetz, Thibaud; Bialais, Emilie; Roeseler, Jean; Depoortere, Virginie; Michotte, Jean-Bernard; Wittebole, Xavier; Ehrmann, Stephan; Laterre, Pierre-François; Jamar, François; Reychler, Gregory

    2017-10-01

    High-flow nasal cannula use is developing in ICUs. The aim of this study was to compare aerosol efficiency by using two nebulizers through a high-flow nasal cannula: the most commonly used jet nebulizer (JN) and a more efficient vibrating-mesh nebulizer (VN). Aerosol delivery of diethylenetriaminepentaacetic acid labeled with technetium-99m (4 mCi/4 mL) to the lungs by using a VN (Aerogen Solo ® ; Aerogen Ltd., Galway, Ireland) and a constant-output JN (Opti-Mist Plus Nebulizer ® ; ConvaTec, Bridgewater, NJ) through a high-flow nasal cannula (Optiflow ® ; Fisher & Paykel, New Zealand) was compared in six healthy subjects. Flow rate was set at 30 L/min through the heated humidified circuit. Pulmonary and extrapulmonary deposition was measured by single-photon emission computed tomography combined with a low-dose computed tomographic scan and by planar scintigraphy. Lung deposition was only 3.6 (2.1-4.4) and 1 (0.7-2)% of the nominal dose with the VN and the JN, respectively (p < 0.05). The JN showed higher retained doses than the VN. However, both nebulizers were associated with substantial deposition in the single limb circuit, the humidification chamber, and the nasal cannula [58.2 (51.6-61.6)% of the nominal dose with the VN versus 19.2 (15.8-22.9)% of the nominal dose with the JN, p < 0.05] and in the upper respiratory tract [17.6 (13.4-27.9)% of the nominal dose with the VN and 8.6 (6.0-11.0)% of the nominal dose with the JN, p < 0.05], especially in the nasal cavity. In the specific conditions of the study, pulmonary drug delivery through the high-flow nasal cannula is about 1%-4% of the initial amount of drugs placed in the nebulizer, despite the higher efficiency of the VN as compared with the JN.

  6. Cold hematoma visualized by technetium-99m labeled red blood cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beanblossom, M.

    1986-09-01

    A 64-yr-old male was admitted to the hospital with severe abdominal pain associated with vomiting. Upon examination, the patients Hgb was 7.8 with a WBC count of 13.3 band cells of 7 and a recticulocyte count of 3.4, no evidence of gastrointestinal bleeding. The patient's prior history revealed involvement in an automobile accident approx. 10 days prior to this admission. At that time, he suffered multiple contusions and abrasions with a fracture to his left clavicle. Apparently there were no episodes of abdominal pain or vomiting prior to the onset of illness perceived on the day of admission. A liver/spleenmore » scan was done. Four millicuries of /sup 99m/Tc-sulfur colloid were intravenously injected using a bolus injection technique while obtaining multiple dynamic images. The flow study was unremarkable, demonstrating no abnormalities to the great vessels and good perfusion to both organs. Static images of the liver and spleen revealed a straightening or flatness to the lateral border of the spleen with a small diminished area of tracer sulfur colloid localization at the posterolateral aspect of that organ. This finding raised the suspicion that a small subcapsular hematoma had developed at the mid-posterolateral aspect of the spleen. Twenty-four hours after hospital admission, 4 units of packed RBCs were transfused into the patient. Although there was at this time still no evidence of abnormal bleeding, it was felt that because of the strong symptomatic correlation for internal bleeding, a radionuclide bleeding site study should be ordered and immediately performed.« less

  7. Noninvasive evaluation of active lower gastrointestinal bleeding: comparison between contrast-enhanced MDCT and 99mTc-labeled RBC scintigraphy.

    PubMed

    Zink, Stephen I; Ohki, Stephen K; Stein, Barry; Zambuto, Domenic A; Rosenberg, Ronald J; Choi, Jenny J; Tubbs, Daniel S

    2008-10-01

    The purpose of our study was to compare contrast-enhanced MDCT and (99m)Tc-labeled RBC scanning for the evaluation of active lower gastrointestinal bleeding. Over 17 months, 55 patients (32 men, 23 women; age range, 21-92 years) were evaluated prospectively with contrast-enhanced MDCT using 100 mL of iopromide 300 mg I/mL. Technetium-99m-labeled RBC scans were obtained on 41 of 55 patients and select patients underwent angiography for attempted embolization. Each imaging technique was reviewed in a blinded fashion for sensitivity for detection of active bleeding as well as the active lower gastrointestinal bleeding location. Findings were positive on both examinations in eight patients and negative on both examinations in 20 patients. Findings were positive on contrast-enhanced MDCT and negative on (99m)Tc-labeled RBC in two patients; findings were negative on contrast-enhanced MDCT and positive on (99m)Tc-labeled RBC in 11 patients. Statistics showed significant disagreement, with simple agreement = 68.3%, kappa = 0.341, and p = 0.014. Sixteen of 60 (26.7%) contrast-enhanced MDCT scans were positive prospectively, with all accurately localizing the site of bleeding and identification of the underlying lesion in eight of 16 (50%). Nineteen of 41 (46.3%) (99m)Tc-labeled RBC scans were positive. Eighteen of 41 matched patients went on to angiography. In four of these 18 (22.2%) patients, the site of bleeding was confirmed by angiography, but in 14 of 18 (77.8%), the findings were negative. Contrast-enhanced MDCT and (99m)Tc-labeled RBC scanning show significant disagreement for evaluation of active lower gastrointestinal bleeding. Contrast-enhanced MDCT appears effective for detection and localization in cases of active lower gastrointestinal bleeding in which hemorrhage is active at the time of CT.

  8. Evaluation of the biliary and brain distribution of technetium Tc 99m sestamibi in healthy dogs with the ABCB1 wildtype genotype before and after treatment with spinosad.

    PubMed

    MacKay, Christopher S; Mattoon, John S; Roberts, Gregory D; Tucker, Russell L; Morimoto, Trevor R; Mealey, Katrina L

    2012-06-01

    To determine whether the reported drug-drug interaction between the flea medication spinosad and ivermectin is attributable to inhibition of P-glycoprotein by spinosad. 6 healthy adult dogs with the ABCB1 wildtype genotype. The study was conducted as a prospective, masked, randomized crossover design. Six dogs were allocated to 2 groups; each dog served as its own control animal. Dogs in one of the groups received spinosad at the manufacturer's recommended dose; the other group received no treatment. Forty-eight hours later, scintigraphic imaging of the head and abdomen were performed with the radiolabeled P-glycoprotein substrate methoxy-isobutyl-isonitrile (sestamibi) in both groups of dogs. After a washout period of 60 days, the dogs in each group received the alternate treatment, and scintigraphic imaging again was performed 48 hours later. Gallbladder-to-liver and brain-to-neck musculature ratios of technetium Tc 99m sestamibi were calculated for each dog and compared between treatments. No significant differences in gallbladder-to-liver or brain-to-neck musculature ratios were found between treatments. Results provided evidence that spinosad did not inhibit P-glycoprotein function 48 hours after spinosad was administered at the manufacturer's recommended dose. Further investigations will be necessary to elucidate the mechanism of the reported toxic interaction between spinosad and ivermectin.

  9. Estimation of Organ Absorbed Doses in Patients from 99mTc-diphosphonate Using the Data of MIRDose Software

    PubMed Central

    Shahbazi-Gahrouei, Daryoush; Cheki, Mohsen; Moslehi, Masoud

    2012-01-01

    The purpose of this study was to compare estimation of radiation absorbed doses to patients following bone scans with technetium-99m-labeled methylene diphosphonate (MDP) with the estimates given in MIRDose software. In this study, each patient was injected 25 mCi of 99mTc-MDP. Whole-body images from thirty patients were acquired by gamma camera at 10, 60, 90, 180 minutes after 99mTc-MDP injection. To determine the amount of activity in each organ, conjugate view method was applied on images. MIRD equation was then used to estimate absorbed doses in different organs of patients. At the end, absorbed dose values obtained in this study were compared with the data of MIRDose software. The absorbed doses per unit of injected activity (mGy/MBq × 10–4) for liver, kidneys, bladder wall and spleen were 3.86 ± 1.1, 38.73 ± 4.7, 4.16 ± 1.8 and 3.91 ± 1.3, respectively. The results of this study may be useful to estimate the amount of activity that can be administered to the patient and also showed that methods used in the study for absorbed dose calculation is in good agreement with the data of MIRDose software and it is possible to use by a clinician. PMID:23724374

  10. Single-photon emission of InAs/InP quantum dashes at 1.55 μm and temperatures up to 80 K

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dusanowski, Ł., E-mail: lukasz.dusanowski@pwr.edu.pl; Syperek, M.; Misiewicz, J.

    2016-04-18

    We report on single photon emission from a self-assembled InAs/InGaAlAs/InP quantum dash emitting at 1.55 μm at the elevated temperatures. The photon auto-correlation histograms of the emission from a charged exciton indicate clear antibunching dips with as-measured g{sup (2)}(0) values significantly below 0.5 recorded at temperatures up to 80 K. It proves that the charged exciton complex in a single quantum dash of the mature InP-based material system can act as a true single photon source up to at least liquid nitrogen temperature. This demonstrates the huge potential of InAs on InP nanostructures as the non-classical light emitters for long-distance fiber-based securemore » communication technologies.« less

  11. Evaluation of Technetium Getters to Improve the Performance of Cast Stone

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neeway, James J.; Qafoku, Nikolla P.; Serne, R. Jeffrey

    2015-11-01

    Cast Stone has been selected as the preferred waste form for solidification of aqueous secondary liquid effluents from the Hanford Tank Waste Treatment and Immobilization Plant (WTP) process condensates and low-activity waste (LAW) melter off-gas caustic scrubber effluents. Cast Stone is also being evaluated as a supplemental immobilization technology to provide the necessary LAW treatment capacity to complete the Hanford tank waste cleanup mission in a timely and cost effective manner. One of the major radionuclides that Cast Stone has the potential to immobilize is technetium (Tc). The mechanism for immobilization is through the reduction of the highly mobile Tc(VII)more » species to the less mobile Tc(IV) species by the blast furnace slag (BFS) used in the Cast Stone formulation. Technetium immobilization through this method would be beneficial because Tc is one of the most difficult contaminants to address at the U.S. Department of Energy (DOE) Hanford Site due to its complex chemical behavior in tank waste, limited incorporation in mid- to high-temperature immobilization processes (vitrification, steam reformation, etc.), and high mobility in subsurface environments. In fact, the Tank Closure and Waste Management Environmental Impact Statement for the Hanford Site, Richland, Washington (TC&WM EIS) identifies technetium-99 ( 99Tc) as one of the radioactive tank waste components contributing the most to the environmental impact associated with the cleanup of the Hanford Site. The TC&WM EIS, along with an earlier supplemental waste-form risk assessment, used a diffusion-limited release model to estimate the release of different contaminants from the WTP process waste forms. In both of these predictive modeling exercises, where effective diffusivities based on grout performance data available at the time, groundwater at the 100-m down-gradient well exceeded the allowable maximum permissible concentrations for 99Tc. (900 pCi/L). Recent relatively short-term (63

  12. Imaging of irradiated liver with Tc-99m-sulfur colloid and Tc-99m-IDA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gelfand, M.J.; Saha, S.; Aron, B.S.

    1981-09-01

    In three cases, irradiated regions of liver failed to concentrate Tc-99m-sulfur colloid. In two of these three, imaging with Tc-99m-acetanilide iminodiacetic acid (IDA) agents within five days showed near normal hepatic uptake of this hepatobiliary imaging agent. The hepatic parenchymal cells may be imaged with Tc-99m-IDA in some irradiated regions of liver, despite loss of reticuloendothelial cell function.

  13. Un-collimated single-photon imaging system for high-sensitivity small animal and plant imaging.

    PubMed

    Walker, Katherine L; Judenhofer, Martin S; Cherry, Simon R; Mitchell, Gregory S

    2015-01-07

    In preclinical single-photon emission computed tomography (SPECT) system development the primary objective has been to improve spatial resolution by using novel parallel-hole or multi-pinhole collimator geometries. However, such high-resolution systems have relatively poor sensitivity (typically 0.01-0.1%). In contrast, a system that does not use collimators can achieve very high-sensitivity. Here we present a high-sensitivity un-collimated detector single-photon imaging (UCD-SPI) system for the imaging of both small animals and plants. This scanner consists of two thin, closely spaced, pixelated scintillator detectors that use NaI(Tl), CsI(Na), or BGO. The performance of the system has been characterized by measuring sensitivity, spatial resolution, linearity, detection limits, and uniformity. With (99m)Tc (140 keV) at the center of the field of view (20 mm scintillator separation), the sensitivity was measured to be 31.8% using the NaI(Tl) detectors and 40.2% with CsI(Na). The best spatial resolution (FWHM when the image formed as the geometric mean of the two detector heads, 20 mm scintillator separation) was 19.0 mm for NaI(Tl) and 11.9 mm for CsI(Na) at 140 keV, and 19.5 mm for BGO at 1116 keV, which is somewhat degraded compared to the cm-scale resolution obtained with only one detector head and a close source. The quantitative accuracy of the system's linearity is better than 2% with detection down to activity levels of 100 nCi. Two in vivo animal studies (a renal scan using (99m)Tc MAG-3 and a thyroid scan with (123)I) and one plant study (a (99m)TcO4(-) xylem transport study) highlight the unique capabilities of this UCD-SPI system. From the renal scan, we observe approximately a one thousand-fold increase in sensitivity compared to the Siemens Inveon SPECT/CT scanner. UCD-SPI is useful for many imaging tasks that do not require excellent spatial resolution, such as high-throughput screening applications, simple radiotracer uptake studies

  14. Un-collimated single-photon imaging system for high-sensitivity small animal and plant imaging

    DOE PAGES

    Walker, Katherine L.; Judenhofer, Martin S.; Cherry, Simon R.; ...

    2014-12-12

    In preclinical single-photon emission computed tomography (SPECT) system development the primary objective has been to improve spatial resolution by using novel parallel-hole or multi-pinhole collimator geometries. Furthermore, such high-resolution systems have relatively poor sensitivity (typically 0.01% to 0.1%). In contrast, a system that does not use collimators can achieve very high-sensitivity. Here we present a high-sensitivity un-collimated detector single-photon imaging (UCD-SPI) system for the imaging of both small animals and plants. This scanner consists of two thin, closely spaced, pixelated scintillator detectors that use NaI(Tl), CsI(Na), or BGO. The performance of the system has been characterized by measuring sensitivity, spatialmore » resolution, linearity, detection limits, and uniformity. With 99mTc (140 keV) at the center of the field of view (20 mm scintillator separation), the sensitivity was measured to be 31.8% using the NaI(Tl) detectors and 40.2% with CsI(Na). The best spatial resolution (FWHM when the image formed as the geometric mean of the two detector heads, 20 mm scintillator separation) was 19.0 mm for NaI(Tl) and 11.9 mm for CsI(Na) at 140 keV, and 19.5 mm for BGO at 1116 keV, which is somewhat degraded compared to the cm-scale resolution obtained with only one detector head and a close source. The quantitative accuracy of the system’s linearity is better than 2% with detection down to activity levels of 100 nCi. Two in vivo animal studies (a renal scan using 99mTc MAG-3 and a thyroid scan with 123I) and one plant study (a 99mTcO 4- xylem transport study) highlight the unique capabilities of this UCD-SPI system. From the renal scan, we observe approximately a one thousand-fold increase in sensitivity compared to the Siemens Inveon SPECT/CT scanner. In conclusion, UCD-SPI is useful for many imaging tasks that do not require excellent spatial resolution, such as high-throughput screening applications, simple radiotracer uptake

  15. Un-collimated single-photon imaging system for high-sensitivity small animal and plant imaging

    NASA Astrophysics Data System (ADS)

    Walker, Katherine L.; Judenhofer, Martin S.; Cherry, Simon R.; Mitchell, Gregory S.

    2015-01-01

    In preclinical single-photon emission computed tomography (SPECT) system development the primary objective has been to improve spatial resolution by using novel parallel-hole or multi-pinhole collimator geometries. However, such high-resolution systems have relatively poor sensitivity (typically 0.01-0.1%). In contrast, a system that does not use collimators can achieve very high-sensitivity. Here we present a high-sensitivity un-collimated detector single-photon imaging (UCD-SPI) system for the imaging of both small animals and plants. This scanner consists of two thin, closely spaced, pixelated scintillator detectors that use NaI(Tl), CsI(Na), or BGO. The performance of the system has been characterized by measuring sensitivity, spatial resolution, linearity, detection limits, and uniformity. With 99mTc (140 keV) at the center of the field of view (20 mm scintillator separation), the sensitivity was measured to be 31.8% using the NaI(Tl) detectors and 40.2% with CsI(Na). The best spatial resolution (FWHM when the image formed as the geometric mean of the two detector heads, 20 mm scintillator separation) was 19.0 mm for NaI(Tl) and 11.9 mm for CsI(Na) at 140 keV, and 19.5 mm for BGO at 1116 keV, which is somewhat degraded compared to the cm-scale resolution obtained with only one detector head and a close source. The quantitative accuracy of the system’s linearity is better than 2% with detection down to activity levels of 100 nCi. Two in vivo animal studies (a renal scan using 99mTc MAG-3 and a thyroid scan with 123I) and one plant study (a 99mTcO4- xylem transport study) highlight the unique capabilities of this UCD-SPI system. From the renal scan, we observe approximately a one thousand-fold increase in sensitivity compared to the Siemens Inveon SPECT/CT scanner. UCD-SPI is useful for many imaging tasks that do not require excellent spatial resolution, such as high-throughput screening applications, simple radiotracer uptake studies in tumor

  16. Three-dimensional fractal analysis of 99mTc-MAA SPECT images in chronic thromboembolic pulmonary hypertension for evaluation of response to balloon pulmonary angioplasty: association with pulmonary arterial pressure.

    PubMed

    Maruoka, Yasuhiro; Nagao, Michinobu; Baba, Shingo; Isoda, Takuro; Kitamura, Yoshiyuki; Yamazaki, Yuzo; Abe, Koichiro; Sasaki, Masayuki; Abe, Kohtaro; Honda, Hiroshi

    2017-06-01

    Balloon pulmonary angioplasty (BPA) is used for inoperable chronic thromboembolic pulmonary hypertension (CTEPH), but its effect cannot be evaluated noninvasively. We devised a noninvasive quantitative index of response to BPA using three-dimensional fractal analysis (3D-FA) of technetium-99m-macroaggregated albumin (Tc-MAA) single-photon emission computed tomography (SPECT). Forty CTEPH patients who underwent pulmonary perfusion scintigraphy and mean pulmonary arterial pressure (mPAP) measurement by right heart catheterization before and after BPA were studied. The total uptake volume (TUV) in bilateral lungs was determined from maximum intensity projection Tc-MAA SPECT images. Fractal dimension was assessed by 3D-FA. Parameters were compared before and after BPA, and between patients with post-BPA mPAP more than 30 mmHg and less than or equal to 30 mmHg. Receiver operating characteristic analysis was carried out. BPA significantly improved TUV (595±204-885±214 ml, P<0.001) and reduced the laterality of uptake (238±147-135±131 ml, P<0.001). Patients with poor therapeutic response (post-BPA mPAP≥30 mmHg, n=16) showed a significantly smaller TUV increase (P=0.044) and a significantly greater post-BPA fractal dimension (P<0.001) than the low-mPAP group. Fractal dimension correlated with mPAP values before and after BPA (P=0.013 and 0.001, respectively). A post-BPA fractal dimension threshold of 2.4 distinguished between BPA success and failure with 75% sensitivity, 79% specificity, 78% accuracy, and area under the curve of 0.85. 3D-FA using Tc-MAA SPECT pulmonary perfusion scintigraphy enables a noninvasive evaluation of the response of CTEPH patients to BPA.

  17. Photoreduction of 99Tc Pertechnetate by Nanometer-Sized Metal Oxides: New Strategies for Formation and Sequestration of Low-Valent Technetium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burton-Pye, Benjamin P.; Radivojevic, Ivana; McGregor, Donna

    2011-11-23

    Technetium-99 ( 99Tc)(β - max: 293.7 keV; t 1/2: 2.1 x 10 5 years) is a byproduct of uranium-235 fission and comprises a large component of radioactive waste. Under aerobic conditions and in a neutral- basic environment, the pertechnetate anion ( 99TcO 4 -) is stable. 99TcO 4 - is very soluble, migrates easily through the environment and does not sorb well onto mineral surfaces, soils or sediments. This study moves forward a new strategy for the reduction of TcO 4 - and chemical incorporation of the reduced 99Tc into a metal oxide material. This strategy employs a single material,more » a polyoxometalate (POM), α 2-[P 2W 17O 61] 10-, that can be photoactivated in the presence of 2-propanol to transfer electrons to TcO 4 - and incorporate the reduced 99Tc covalently into the α 2 - framework to form the Tc VO species, Tc VO(α 2-P 2W 17O 61) 7-. This occurs via the formation of an intermediate species that slowly converts to Tc VO(α 2-P 2W 17O 61) 7-. EXAFS and XANES analysis and preliminary EPR analysis, suggests that the intermediate consists of a Tc(IV) α 2- species where the 99Tc is likely bound to only 2 of the 4 W-O oxygen atoms in the α 2-[P 2W 17O 61] 10- defect. This intermediate then oxidizes and converts to the 99Tc VO(α 2-P 2W 17O 61) 7- product. The reduction and incorporation of 99TcO 4- was accomplished in a ''one pot'' reaction using both sunlight and UV irradiation, and monitored as a function of time using multinuclear NMR and radio TLC. The process was further probed by the ''step-wise'' generation of reduced α 2-P 2W 17O 61 12- through bulk electrolysis followed by the addition of TcO 4 -. The reduction and incorporation of ReO 4 -, as a non-radioactive surrogate for 99Tc, does not proceed through the intermediate species, and Re VO is incorporated quickly into the α 2-[P 2W 17O 61] 10- defect. These observations are consistent with the periodic trends of 99Tc and Re. Specifically, 99Tc is more easily reduced compared to Re. In addition

  18. Design on compatible stealth photonic crystal of nearmiddle infrared and 1.06 μm laser

    NASA Astrophysics Data System (ADS)

    Zhang, Ji-kui; Wang, Jia-Chun; Wang, Qi-Chao

    2016-01-01

    In the near and middle infrared atmospheric window, infrared stealth material require a low absorptivity (which means a low emissivity according to Kirchhoff's law of black body), at the same time, it also requires high absorptivity so as to decrease the reflectance at military laser wavelength of 1.06μm. Under this circumstances, compatible stealth of infrared and laser is an urgent demand, but the demand is ambivalent for conventional materials. Photonic crystal (PC), as a new type of artificial periodic structure function material, can realize broadband thermal infrared stealth based on its high-reflection photon forbidden band(also called photonic band gap). The high-reflection photon forbidden band of PC can be adjusted to near and middle infrared wave band through some rational methods. When a defect was added into the periodic structure of PC, a "hole-digging" reflection spectrum, which is high absorption at military laser wavelength of 1.06μm, can be achieved, so compatible stealth of near and middle infrared and military laser wavelength of 1.06μm can be achieved too. In this paper, we selected near and middle infrared-transparent materials, Te and MgF2 , as high refractive index and low refractive index material respectively, and designed a one-dimensional one-defect-mode PC whose photon forbidden band was broadened to 1-5μm by constructing two photonic crystals into one. The optical property of the PC was calculated by Transfer matrix method(TMM) of thin-film optical theory, and the results shows that the as-designed PC has a high spectral reflectance in the near and middle infrared band, among which the reflectivity in 1.68μm 5.26μm band reached more than 90%, and the 2.48 5.07μm band even reached 99.99%. The result also shows that between the band gap of 1-5μm, there are one defect mode locating in the wavelength of 1.06μm, whose reflectance is below 0.70%, which means its spectral absorptivity is greater than 99.30%. All the above we have

  19. Right ventricle performances with echocardiography and 99mTc myocardial perfusion imaging in pulmonary arterial hypertension patients.

    PubMed

    Liu, Jie; Fei, Lei; Huang, Guang-Qing; Shang, Xiao-Ke; Liu, Mei; Pei, Zhi-Jun; Zhang, Yong-Xue

    2018-05-01

    Right heart catheterization is commonly used to measure right ventricle hemodynamic parameters and is the gold standard for pulmonary arterial hypertension diagnosis; however, it is not suitable for patients' long-term follow-up. Non-invasive echocardiography and nuclear medicine have been applied to measure right ventricle anatomy and function, but the guidelines for the usefulness of clinical parameters remain to be established. The goal of this study is to identify reliable clinical parameters of right ventricle function in pulmonary arterial hypertension patients and analyze the relationship of these clinical parameters with the disease severity of pulmonary arterial hypertension. In this study, 23 normal subjects and 23 pulmonary arterial hypertension patients were recruited from January 2015 to March 2016. Pulmonary arterial hypertension patients were classified into moderate and severe pulmonary arterial hypertension groups according to their mean pulmonary arterial pressure levels. All the subjects were subjected to physical examination, chest X-ray, 12-lead electrocardiogram, right heart catheterization, two-dimensional echocardiography, and technetium 99m ( 99m Tc) myocardial perfusion imaging. Compared to normal subjects, the right heart catheterization indexes including right ventricle systolic pressure, right ventricle end diastolic pressure, pulmonary artery systolic pressure, pulmonary artery diastolic pressure, pulmonary vascular resistance, and right ventricle end systolic pressure increased in pulmonary arterial hypertension patients and were correlated with mean pulmonary arterial pressure levels. Echocardiography parameters, including tricuspid regurgitation peak velocity, tricuspid regurgitation pressure gradient, tricuspid annular plane systolic excursion and fractional area, right ventricle-myocardial performance index, were significantly associated with the mean pulmonary arterial pressure levels in pulmonary arterial hypertension patients

  20. Quantum key distribution over 120 km using ultrahigh purity single-photon source and superconducting single-photon detectors

    PubMed Central

    Takemoto, Kazuya; Nambu, Yoshihiro; Miyazawa, Toshiyuki; Sakuma, Yoshiki; Yamamoto, Tsuyoshi; Yorozu, Shinichi; Arakawa, Yasuhiko

    2015-01-01

    Advances in single-photon sources (SPSs) and single-photon detectors (SPDs) promise unique applications in the field of quantum information technology. In this paper, we report long-distance quantum key distribution (QKD) by using state-of-the-art devices: a quantum-dot SPS (QD SPS) emitting a photon in the telecom band of 1.5 μm and a superconducting nanowire SPD (SNSPD). At the distance of 100 km, we obtained the maximal secure key rate of 27.6 bps without using decoy states, which is at least threefold larger than the rate obtained in the previously reported 50-km-long QKD experiment. We also succeeded in transmitting secure keys at the rate of 0.307 bps over 120 km. This is the longest QKD distance yet reported by using known true SPSs. The ultralow multiphoton emissions of our SPS and ultralow dark count of the SNSPD contributed to this result. The experimental results demonstrate the potential applicability of QD SPSs to practical telecom QKD networks. PMID:26404010

  1. Tc-99 Decontamination From Heat Treated Gaseous Diffusion Membrane -Phase I

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oji, L.; Wilmarth, B.; Restivo, M.

    2017-03-13

    Uranium gaseous diffusion cascades represent a significant environmental challenge to dismantle, containerize and dispose as low-level radioactive waste. Baseline technologies rely on manual manipulations involving direct access to technetium-contaminated piping and materials. There is a potential to utilize novel thermal decontamination technologies to remove the technetium and allow for on-site disposal of the very large uranium converters. Technetium entered these gaseous diffusion cascades as a hexafluoride complex in the same fashion as uranium. Technetium, as the isotope Tc-99, is an impurity that follows uranium in the first cycle of the Plutonium and Uranium Extraction (PUREX) process. The technetium speciation ormore » exact form in the gas diffusion cascades is not well defined. Several forms of Tc-99 compounds, mostly the fluorinated technetium compounds with varying degrees of volatility have been speculated by the scientific community to be present in these cascades. Therefore, there may be a possibility of using thermal desorption, which is independent of the technetium oxidation states, to perform an in situ removal of the technetium as a volatile species and trap the radionuclide on sorbent traps which could be disposed as low-level waste.« less

  2. Functional discrepancy between two liver lobes after hemilobe biliary drainage in patients with jaundice and bile duct cancer: an appraisal using (99m)Tc-GSA SPECT/CT fusion imaging.

    PubMed

    Sumiyoshi, Tatsuaki; Shima, Yasuo; Okabayashi, Takehiro; Noda, Yoshihiro; Hata, Yasuhiro; Murata, Yoriko; Kozuki, Akihito; Tokumaru, Teppei; Nakamura, Toshio; Uka, Kiminori

    2014-11-01

    To determine the functional discrepancy between the two liver lobes using technetium 99m ((99m)Tc) diethylenetriamine-pentaacetic acid-galactosyl human serum albumin ( GSA diethylenetriamine-pentaacetic acid-galactosyl human serum albumin ) single photon emission computed tomography (SPECT)/computed tomography (CT) fusion imaging following preoperative biliary drainage and portal vein embolization ( PVE portal vein embolization ) in patients with jaundice who have bile duct cancer ( BDC bile duct cancer ). This retrospective study was approved by the institutional review board, with waiver of informed consent. Preoperative (99m)Tc- GSA diethylenetriamine-pentaacetic acid-galactosyl human serum albumin SPECT/CT fusion images from 32 patients with extrahepatic BDC bile duct cancer were retrospectively reviewed. Patients were classified into four groups according to the extent of biliary drainage and presence of a preoperative right PVE portal vein embolization : right lobe drainage group (right drainage), bilateral lobe drainage group (bilateral drainage), left lobe drainage group (left drainage), and left lobe drainage with right PVE portal vein embolization group (left drainage with right PVE portal vein embolization ). Percentage volume and percentage function were measured in each lobe using fusion imaging. The ratio between percentage function and percentage volume (the function-to-volume ratio) was calculated for each lobe, and the results were compared among the four groups. Statistical analysis was performed with Wilcoxon signed-rank tests and Mann-Whitney U tests. The median values for the function-to-volume ratio in the right drainage, bilateral drainage, left drainage, and left drainage with right PVE portal vein embolization group were 1.12, 1.05, 1.02, and 0.81 in the right lobe; and 0.51, 0.88, 0.96, and 1.17 in the left lobe. Significant differences in the function-to-volume ratio were observed among the four groups (right drainage vs bilateral

  3. [Importance of parathyroid SPECT and 99mTc scintigraphy, and of clinical, laboratorial, ultrasonographic and citologic correlation in the pre-operative localization of the parathyroid adenoma - pictorial assay].

    PubMed

    Oliveira, Marco Antônio Condé de; Maeda, Sérgio Setsuo; Dreyer, Patrícia; Lobo, Alberto; Andrade, Victor Piana de; Hoff, Ana O; Biscolla, Rosa Paula Mello; Smanio, Paola; Brandão, Cynthia M A; Vieira, José G

    2010-06-01

    In patients with primary hyperparathyroidism, candidates for surgical intervention, the parathyroid pre-operative localization is of fundamental importance in planning the appropriate surgical approach. The additional acquisition of SPECT and Technetium-99m images, during parathyroid scintigraphy with Sestamibi, is not common practice. Usually, only planar image acquisition, 15 minutes prior and 2 hours after radiopharmaceutical administration, is performed. In our experience, the complete protocol in parathyroid scintigraphy increases the accuracy of pre-operative parathyroid localization. The complete utilization of all available nuclear medicine methods (SPECT e 99mTc) and image interpretation in a multidisciplinary context can improve the accuracy of parathyroid scintigraphy.

  4. Active temporal multiplexing of indistinguishable heralded single photons

    PubMed Central

    Xiong, C.; Zhang, X.; Liu, Z.; Collins, M. J.; Mahendra, A.; Helt, L. G.; Steel, M. J.; Choi, D. -Y.; Chae, C. J.; Leong, P. H. W.; Eggleton, B. J.

    2016-01-01

    It is a fundamental challenge in quantum optics to deterministically generate indistinguishable single photons through non-deterministic nonlinear optical processes, due to the intrinsic coupling of single- and multi-photon-generation probabilities in these processes. Actively multiplexing photons generated in many temporal modes can decouple these probabilities, but key issues are to minimize resource requirements to allow scalability, and to ensure indistinguishability of the generated photons. Here we demonstrate the multiplexing of photons from four temporal modes solely using fibre-integrated optics and off-the-shelf electronic components. We show a 100% enhancement to the single-photon output probability without introducing additional multi-photon noise. Photon indistinguishability is confirmed by a fourfold Hong–Ou–Mandel quantum interference with a 91±16% visibility after subtracting multi-photon noise due to high pump power. Our demonstration paves the way for scalable multiplexing of many non-deterministic photon sources to a single near-deterministic source, which will be of benefit to future quantum photonic technologies. PMID:26996317

  5. Development of Alternative Technetium Waste Forms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Czerwinski, Kenneth

    2013-09-13

    The UREX+1 process is under consideration for the separation of transuranic elements from spent nuclear fuel. The first steps of this process extract the fission product technicium-99 ({sup 99}Tc) into an organic phase containing tributylphosphate together with uranium. Treatment of this stream requires the separation of Tc from U and placement into a suitable waste storage form. A potential candidate waste form involves immobilizing the Tc as an alloy with either excess metallic zirconium or stainless steel. Although Tc-Zr alloys seem to be promising waste forms, alternative materials must be investigated. Innovative studies related to the synthesis and behavior ofmore » a different class of Tc materials will increase the scientific knowledge related to development of Tc waste forms. These studies will also provide a better understanding of the behavior of {sup 99}Tc in repository conditions. A literature survey has selected promising alternative waste forms for further study: technetium metallic alloys, nitrides, oxides, sulfides, and pertechnetate salts. The goals of this project are to 1) synthesize and structurally characterize relevant technetium materials that may be considered as waste forms, 2) investigate material behavior in solution under different conditions of temperature, electrochemical potential, and radiation, and 3) predict the long-term behavior of these materials.« less

  6. Development and characterization of a 99m Tc-tricarbonyl-labelled estradiol derivative obtained by "Click Chemistry" with potential application in estrogen receptors imaging.

    PubMed

    Tejería, María Emilia; Giglio, Javier; Dematteis, Silvia; Rey, Ana

    2017-09-01

    Assessment of the presence of estrogen receptors in breast cancer is crucial for treatment planning. With the objective to develop a potential agent for estrogen receptors imaging, we present the development and characterization of a 99m Tc-tricarbonyl-labelled estradiol derivative. Using ethinylestradiol as starting material, an estradiol derivative bearing a 1,4-disubstituted 1,2,3-triazole-containing tridentate ligand system was synthesized by "Click Chemistry" and fully characterized. Labelling with high yield and radiochemical purity was achieved through the formation of a 99m Tc-tricarbonyl complex. The radiolabelled compound was stable, exhibited moderate binding to plasma protein (approximately 33%) and lipophilicity in the adequate range (logP 1.3 ± 0.1 at pH 7.4). Studies in MCF7 showed promising uptake values (approximately 2%). However, more than 50% of the activity is quickly released from the cell. Biodistribution experiments in normal rats confirmed the expected "in vivo" stability of the radiotracer but showed very high gastrointestinal and liver activity, which is inconvenient for in vivo applications. Taking into consideration the well-documented influence of the chelating system in the physicochemical and biological behaviour of technetium-labelled small biomolecules, research will be continued using the same pharmacophore but different complexation modalities of technetium. Copyright © 2017 John Wiley & Sons, Ltd.

  7. WE-AB-204-12: Dosimetry at the Sub-Cellular Scale of Auger-Electron Emitter 99m-Tc in a Mouse Single Thyroid Follicle Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taborda, A; Benabdallah, N; Desbree, A

    2015-06-15

    Purpose: To perform a dosimetry study at the sub-cellular scale of Auger-electron emitter 99m-Tc using a mouse single thyroid cellular model to investigate the contribution of the 99m-Tc Auger-electrons to the absorbed dose and possible link to the thyroid stunning in in vivo experiments in mice, recently reported in literature. Methods: The simulation of S-values for Auger-electron emitting radionuclides was performed using both the recent MCNP6 software and the Geant4-DNA extension of the Geant4 toolkit. The dosimetric calculations were validated through comparison with results from literature, using a simple model of a single cell consisting of two concentric spheres ofmore » unit density water and for six Auger-electron emitting radionuclides. Furthermore, the S-values were calculated using a single thyroid follicle model for uniformly distributed 123-I and 125-I radionuclides and compared with published S-values. After validation, the simulation of the S-values was performed for the 99m-Tc radionuclide within the several mouse thyroid follicle cellular compartments, considering the radiative and non-radiative transitions of the 99m-Tc radiation spectrum. Results: The calculated S-values using MCNP6 are in good agreement with the results from literature, validating its use for the 99m-Tc S-values calculations. The most significant absorbed dose corresponds to the case where the radionuclide is uniformly distributed in the follicular cell’s nucleus, with a S-value of 7.8 mGy/disintegration, due mainly to the absorbed Auger-electrons. The results show that, at a sub-cellular scale, the emitted X-rays and gamma particles do not contribute significantly to the absorbed dose. Conclusion: In this work, MCNP6 was validated for dosimetric studies at the sub-cellular scale. It was shown that the contribution of the Auger-electrons to the absorbed dose is important at this scale compared to the emitted photons’ contribution and can’t be neglected. The obtained S

  8. Multiple-Event, Single-Photon Counting Imaging Sensor

    NASA Technical Reports Server (NTRS)

    Zheng, Xinyu; Cunningham, Thomas J.; Sun, Chao; Wang, Kang L.

    2011-01-01

    The single-photon counting imaging sensor is typically an array of silicon Geiger-mode avalanche photodiodes that are monolithically integrated with CMOS (complementary metal oxide semiconductor) readout, signal processing, and addressing circuits located in each pixel and the peripheral area of the chip. The major problem is its single-event method for photon count number registration. A single-event single-photon counting imaging array only allows registration of up to one photon count in each of its pixels during a frame time, i.e., the interval between two successive pixel reset operations. Since the frame time can t be too short, this will lead to very low dynamic range and make the sensor merely useful for very low flux environments. The second problem of the prior technique is a limited fill factor resulting from consumption of chip area by the monolithically integrated CMOS readout in pixels. The resulting low photon collection efficiency will substantially ruin any benefit gained from the very sensitive single-photon counting detection. The single-photon counting imaging sensor developed in this work has a novel multiple-event architecture, which allows each of its pixels to register as more than one million (or more) photon-counting events during a frame time. Because of a consequently boosted dynamic range, the imaging array of the invention is capable of performing single-photon counting under ultra-low light through high-flux environments. On the other hand, since the multiple-event architecture is implemented in a hybrid structure, back-illumination and close-to-unity fill factor can be realized, and maximized quantum efficiency can also be achieved in the detector array.

  9. Single-Photon-Sensitive HgCdTe Avalanche Photodiode Detector

    NASA Technical Reports Server (NTRS)

    Huntington, Andrew

    2013-01-01

    The purpose of this program was to develop single-photon-sensitive short-wavelength infrared (SWIR) and mid-wavelength infrared (MWIR) avalanche photodiode (APD) receivers based on linear-mode HgCdTe APDs, for application by NASA in light detection and ranging (lidar) sensors. Linear-mode photon-counting APDs are desired for lidar because they have a shorter pixel dead time than Geiger APDs, and can detect sequential pulse returns from multiple objects that are closely spaced in range. Linear-mode APDs can also measure photon number, which Geiger APDs cannot, adding an extra dimension to lidar scene data for multi-photon returns. High-gain APDs with low multiplication noise are required for efficient linear-mode detection of single photons because of APD gain statistics -- a low-excess-noise APD will generate detectible current pulses from single photon input at a much higher rate of occurrence than will a noisy APD operated at the same average gain. MWIR and LWIR electron-avalanche HgCdTe APDs have been shown to operate in linear mode at high average avalanche gain (M > 1000) without excess multiplication noise (F = 1), and are therefore very good candidates for linear-mode photon counting. However, detectors fashioned from these narrow-bandgap alloys require aggressive cooling to control thermal dark current. Wider-bandgap SWIR HgCdTe APDs were investigated in this program as a strategy to reduce detector cooling requirements.

  10. Clickable, hydrophilic ligand for fac-[M(I)(CO)3](+) (M = Re/(99m)Tc) applied in an S-functionalized α-MSH peptide.

    PubMed

    Kasten, Benjamin B; Ma, Xiaowei; Liu, Hongguang; Hayes, Thomas R; Barnes, Charles L; Qi, Shibo; Cheng, Kai; Bottorff, Shalina C; Slocumb, Winston S; Wang, Jing; Cheng, Zhen; Benny, Paul D

    2014-03-19

    The copper(I)-catalyzed azide-alkyne cycloaddition (CuAAC) click reaction was used to incorporate alkyne-functionalized dipicolylamine (DPA) ligands (1 and 3) for fac-[M(I)(CO)3](+) (M = Re/(99m)Tc) complexation into an α-melanocyte stimulating hormone (α-MSH) peptide analogue. A novel DPA ligand with carboxylate substitutions on the pyridyl rings (3) was designed to increase the hydrophilicity and to decrease in vivo hepatobiliary retention of fac-[(99m)Tc(I)(CO)3](+) complexes used in single photon emission computed tomography (SPECT) imaging studies with targeting biomolecules. The fac-[Re(I)(CO)3(3)] complex (4) was used for chemical characterization and X-ray crystal analysis prior to radiolabeling studies between 3 and fac-[(99m)Tc(I)(OH2)3(CO)3](+). The corresponding (99m)Tc complex (4a) was obtained in high radiochemical yields, was stable in vitro for 24 h during amino acid challenge and serum stability assays, and showed increased hydrophilicity by log P analysis compared to an analogous complex with nonfunctionalized pyridine rings (2a). An α-MSH peptide functionalized with an azide was labeled with fac-[M(I)(CO)3](+) using both click, then chelate (CuAAC reaction with 1 or 3 followed by metal complexation) and chelate, then click (metal complexation of 1 and 3 followed by CuAAC with the peptide) strategies to assess the effects of CuAAC conditions on fac-[M(I)(CO)3](+) complexation within a peptide framework. The peptides from the click, then chelate strategy had different HPLC tR's and in vitro stabilities compared to those from the chelate, then click strategy, suggesting nonspecific coordination of fac-[M(I)(CO)3](+) using this synthetic route. The fac-[M(I)(CO)3](+)-complexed peptides from the chelate, then click strategy showed >90% stability during in vitro challenge conditions for 6 h, demonstrated high affinity and specificity for the melanocortin 1 receptor (MC1R) in IC50 analyses, and led to moderately high uptake in B16F10 melanoma cells

  11. Global Xenon-133 Emission Inventory Caused by Medical Isotope Production and Derived from the Worldwide Technetium-99m Demand

    NASA Astrophysics Data System (ADS)

    Kalinowski, Martin B.; Grosch, Martina; Hebel, Simon

    2014-03-01

    Emissions from medical isotope production are the most important source of background for atmospheric radioxenon measurements, which are an essential part of nuclear explosion monitoring. This article presents a new approach for estimating the global annual radioxenon emission inventory caused by medical isotope production using the amount of Tc-99m applications in hospitals as the basis. Tc-99m is the most commonly used isotope in radiology and dominates the medical isotope production. This paper presents the first estimate of the global production of Tc-99m. Depending on the production and transport scenario, global xenon emissions of 11-45 PBq/year can be derived from the global isotope demand. The lower end of this estimate is in good agreement with other estimations which are making use of reported releases and realistic process simulations. This proves the validity of the complementary assessment method proposed in this paper. It may be of relevance for future emission scenarios and for estimating the contribution to the global source term from countries and operators that do not make sufficient radioxenon release information available. It depends on sound data on medical treatments with radio-pharmaceuticals and on technical information on the production process of the supplier. This might help in understanding the apparent underestimation of the global emission inventory that has been found by atmospheric transport modelling.

  12. [Renal excretion of methylene-diphosphate-technium-99m. Preliminary observations].

    PubMed

    Vattimo, A; Martini, G

    1983-11-30

    The purpose of this study is to elucidate the mechanism of the renal excretion of 99mTc-MDP in man. We compared the renal clearance of 99mTc-MDP and 51Cr-EDTA (glomerular filtration rate agent). Since the 99mTc-MDP is bound to the plasma protein, the free fraction was calculated by dialysis. The clearances were obtained by single-injection technique. The plasma disappearance of the tracers was resolved into three exponential functions and area was calculated. The clearance was calculated by dividing the amount of the tracers excreted during the first four hours and the plasma area. In this study no difference was found in the clearance of the two agents. These findings suggest that the renal excretion of diphosphonate is related to the glomerular filtration rate.

  13. Quantum State Transfer from a Single Photon to a Distant Quantum-Dot Electron Spin

    NASA Astrophysics Data System (ADS)

    He, Yu; He, Yu-Ming; Wei, Yu-Jia; Jiang, Xiao; Chen, Kai; Lu, Chao-Yang; Pan, Jian-Wei; Schneider, Christian; Kamp, Martin; Höfling, Sven

    2017-08-01

    Quantum state transfer from flying photons to stationary matter qubits is an important element in the realization of quantum networks. Self-assembled semiconductor quantum dots provide a promising solid-state platform hosting both single photon and spin, with an inherent light-matter interface. Here, we develop a method to coherently and actively control the single-photon frequency bins in superposition using electro-optic modulators, and measure the spin-photon entanglement with a fidelity of 0.796 ±0.020 . Further, by Greenberger-Horne-Zeilinger-type state projection on the frequency, path, and polarization degrees of freedom of a single photon, we demonstrate quantum state transfer from a single photon to a single electron spin confined in an InGaAs quantum dot, separated by 5 m. The quantum state mapping from the photon's polarization to the electron's spin is demonstrated along three different axes on the Bloch sphere, with an average fidelity of 78.5%.

  14. Atomic Source of Single Photons in the Telecom Band

    NASA Astrophysics Data System (ADS)

    Dibos, A. M.; Raha, M.; Phenicie, C. M.; Thompson, J. D.

    2018-06-01

    Single atoms and atomlike defects in solids are ideal quantum light sources and memories for quantum networks. However, most atomic transitions are in the ultraviolet-visible portion of the electromagnetic spectrum, where propagation losses in optical fibers are prohibitively large. Here, we observe for the first time the emission of single photons from a single Er3 + ion in a solid-state host, whose optical transition at 1.5 μ m is in the telecom band, allowing for low-loss propagation in optical fiber. This is enabled by integrating Er3 + ions with silicon nanophotonic structures, which results in an enhancement of the photon emission rate by a factor of more than 650. Dozens of distinct ions can be addressed in a single device, and the splitting of the lines in a magnetic field confirms that the optical transitions are coupled to the electronic spin of the Er3 + ions. These results are a significant step towards long-distance quantum networks and deterministic quantum logic for photons based on a scalable silicon nanophotonics architecture.

  15. Does the Clearance of Inhaled (99m)Tc-Sestamibi Correlate with Multidrug Resistance Protein 1 Expression in the Human Lung?

    PubMed

    Mohan, Hosahalli K; Routledge, Thomas; Cane, Paul; Livieratos, Lefteris; Ballinger, James R; Peters, Adrien M

    2016-09-01

    Purpose To examine the relation between the lung elimination rate of inhaled technetium 99m ((99m)Tc)-sestamibi and immunohistochemical expression of bronchopulmonary multidrug resistance protein 1 (MRP1) and permeability glycoprotein (P-gp) and assess the repeatability of the inhaled (99m)Tc-sestamibi clearance technique. Materials and Methods (99m)Tc-sestamibi is a known substrate for P-gp and MRP1, which are established cellular drug efflux transporters. The elimination rate of (99m)Tc-sestamibi from the lungs after inhalation as an aerosol has been hypothesized to be regulated by expression of these transporters. Institutional ethics committee approval was received for this prospective study. Written informed consent was obtained from all participants. The clearance of inhaled (99m)Tc-sestamibi from the lungs of 13 patients due to undergo surgery for primary lung cancer (five of 13) or spontaneous pneumothorax (eight of 13) was estimated after dynamic imaging of the lungs during a period of 40 minutes. The time taken to clear 50% of inhaled sestamibi (T1/2) was compared with a semiquantitative immunohistochemical assessment (grade 0-3) of MRP1 and P-gp expression in the lung by using parametric and nonparametric tests. The study was repeated in five participants to assess the repeatability of the technique by using a Bland Altman analysis method. Results MRP1 expression was seen in 12 of 13 patients, while P-gp expression was seen in only two. The mean (99m)Tc-sestamibi elimination rate was faster in patients (n = 6) with low levels of MRP1 expression (grade 0-1) and mean T1/2 of 105 minutes ± 20 (standard deviation), compared with those with higher levels of MRP1 expression (grade 2-3, n = 7) and mean T1/2 of 149 minutes ± 28 (P = .008). Bland-Altman analysis revealed excellent agreement between test and retest values. Conclusion Inhaled (99m)Tc-sestamibi clearance study is a repeatable technique demonstrating significant correlation with MRP1 expression in

  16. Time stamping of single optical photons with 10 ns resolution

    NASA Astrophysics Data System (ADS)

    Chakaberia, Irakli; Cotlet, Mircea; Fisher-Levine, Merlin; Hodges, Diedra R.; Nguyen, Jayke; Nomerotski, Andrei

    2017-05-01

    High spatial and temporal resolution are key features for many modern applications, e.g. mass spectrometry, probing the structure of materials via neutron scattering, studying molecular structure, etc.1-5 Fast imaging also provides the capability of coincidence detection, and the further addition of sensitivity to single optical photons with the capability of timestamping them further broadens the field of potential applications. Photon counting is already widely used in X-ray imaging,6 where the high energy of the photons makes their detection easier. TimepixCam is a novel optical imager,7 which achieves high spatial resolution using an array of 256×256 55 μm × 55μm pixels which have individually controlled functionality. It is based on a thin-entrance-window silicon sensor, bump-bonded to a Timepix ASIC.8 TimepixCam provides high quantum efficiency in the optical wavelength range (400-1000 nm). We perform the timestamping of single photons with a time resolution of 20 ns, by coupling TimepixCam to a fast image-intensifier with a P47 phosphor screen. The fast emission time of the P479 allows us to preserve good time resolution while maintaining the capability to focus the optical output of the intensifier onto the 256×256 pixel Timepix sensor area. We demonstrate the capability of the (TimepixCam + image intensifier) setup to provide high-resolution single-photon timestamping, with an effective frame rate of 50 MHz.

  17. Evaluation of 99mTc-MIBI in thyroid gland imaging for the diagnosis of amiodarone-induced thyrotoxicosis

    PubMed Central

    Zhang, Ruiguo

    2017-01-01

    Objective: Amiodarone-induced thyrotoxicosis (AIT) is caused by amiodarone as a side effect of cardiovascular disease treatment. Based on the differences in their pathological and physiological mechanisms, many methods have been developed so far to differentiate AIT subtypes such as colour flow Doppler sonography (CFDS) and 24-h radioiodine uptake (RAIU). However, these methods suffer from inadequate accuracy in distinguishing different types of AITs and sometimes lead to misdiagnosis and delayed treatments. Therefore, there is an unmet demand for an efficient method for accurate classification of AIT. Methods: Technetium-99 methoxyisobutylisonitrile (99mTc-MIBI) thyroid imaging was performed on 15 patients for AIT classification, and the results were compared with other conventional methods such as CFDS, RAIU and 99mTcO4 imaging. Results: High uptake and retention of MIBI in thyroid tissue is characteristic in Type I AIT, while in sharp contrast, low uptake of MIBI in the thyroid tissue was observed in Type II AIT. Mixed-type AIT shows uptake value between Types I and II. MIBI imaging outperforms other methods with a lower misdiagnosis rate. Conclusion: Among the methods evaluated, MIBI imaging enables an accurate identification of Type I, II and mixed-type AITs by showing distinct images for different types of AITs. The results obtained from our selected subjects revealed that MIBI imaging is a reliable method for diagnosis and classification of AITs and MIBI imaging has potential in the treatment of thyroid diseases. Advances in knowledge: 99mTc-MIBI imaging is a useful method for the diagnosis of AIT. It can distinguish different types of AITs especially for mixed-type AIT, which is usually difficult to treat. 99mTc-MIBI has potential advantages over conventional methods in the efficient treatment of AIT. PMID:28106465

  18. 1.3 μm single-photon emission from strain-coupled bilayer of InAs/GaAs quantum dots at the temperature up to 120 K

    NASA Astrophysics Data System (ADS)

    Xue, Yongzhou; Chen, Zesheng; Ni, Haiqiao; Niu, Zhichuan; Jiang, Desheng; Dou, Xiuming; Sun, Baoquan

    2017-10-01

    We report on 1.3 μm single-photon emission based on a self-assembled strain-coupled bilayer of InAs quantum dots (QDs) embedded in a micropillar Bragg cavity at temperature of liquid nitrogen or even as high as 120 K. The obtained single-photon flux into the first lens of the collection optics is 4.2 × 106 and 3.3 × 106/s at 82 and 120 K, respectively, corresponding to a second-order correlation function at zero delay times of 0.27(2) and 0.28(3). This work reports on the significant effect of the micropillar cavity-related enhancement of QD emission and demonstrates an opportunity to employ telecom band single-photon emitters at liquid nitrogen or even higher temperature.

  19. Malignant external otitis: early scintigraphic detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strashun, A.M.; Nejatheim, M.; Goldsmith, S.J.

    1984-02-01

    Pseudomonas otitis externa in elderly diabetics may extend aggressively to adjacent bone, cranial nerves, meninges, and vessels, leading to a clinical diagnosis of ''malignant'' external otitis. Early diagnosis is necessary for successful treatment. This study compares the findings of initial radiographs, thin-section tomography of temporal bone, CT scans of head and neck, technetium-99m methylene diphosphonate (MDP) and gallium-67 citrate scintigraphy, and single-photon emission computed tomography (SPECT) for detection of temporal bone osteomylitis in ten patients fulfilling the clinical diagnostic criteria of malignant external otitis. Skull radiographs were negative in all of the eight patients studied. Thin-section tomography was positive inmore » one of the seven patients studied using this modality. CT scanning suggested osteomyelitis in three of nine patients. Both Tc-99m and Ga-67 citrate scintigraphy were positive in 10 of 10 patients. These results suggest that technetium and gallium scintigraphy are more sensitive than radiographs and CT scans for early detection of malignant external otitis.« less

  20. Pretreatment evaluation of carcinomas of the hypopharynx and larynx with 18F-fluorodeoxyglucose, 123I-alpha-methyl-L-tyrosine and 99mTc-hexakis-2-methoxyisobutylisonitrile.

    PubMed

    Henze, Marcus; Mohammed, Ashour; Mier, Walter; Rudat, Volker; Dietz, Andreas; Nollert, Jörg; Eisenhut, Michael; Haberkorn, Uwe

    2002-03-01

    While fluorine-18 2-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) is helpful in the pretherapeutic evaluation of head and neck cancer, it is only available in selected centres. Therefore, single-photon emission tomography (SPET) tracers would be desirable if they were to demonstrate tumour uptake reliably. This multitracer study was performed to evaluate the pretherapeutic uptake of the SPET tracers iodine-123 alpha-methyl-L-tyrosine (IMT) and technetium-99m hexakis-2-methoxyisobutylisonitrile (99mTc-MIBI) in primary carcinomas of the hypopharynx and larynx and to compare the results with those of FDG PET. We examined 22 fasted patients (20 male, 2 female, mean age 60.5+/-10.2 years) with histologically confirmed carcinoma of the hypopharynx (n=9) or larynx (n=13), within 1 week before therapy. In 20 patients a cervical PET scan was acquired after intravenous injection of 232+/-43 MBq 18F-FDG. Data analysis was semiquantitative, being based on standardised uptake values (SUVs) obtained at 60-90 min after injection. After injection of 570+/-44 MBq 99mTc-MIBI, cervical SPET scans (high-resolution collimator, 64x64 matrix, 64 steps, 40 s each) were obtained in 19 patients, 15 and 60 min after tracer injection. Finally, 15 min after injection of 327+/-93 MBq 123I-IMT (medium-energy collimator, 64x64 matrix, 64 steps, 40 s each) SPET scans were acquired in 15 patients. All images were analysed visually and by calculating the tumour to nuchal muscle ratio. Eighteen of 20 (90%) carcinomas showed an increased glucose metabolism, with a mean SUV of 8.7 and a mean carcinoma to muscle ratio of 7.3. The IMT uptake was increased in 13 of 15 (87%) patients, who had a mean carcinoma to muscle ratio of 2.9. Only 13 of 19 (68%) carcinomas revealed pathological MIBI uptake, with a mean tumour to muscle ratio of 2.2 and no significant difference between early and late MIBI SPET images (P=0.23). In conclusion, in the diagnosis of primary carcinomas of the

  1. [Improvement in nuclear medicine diagnosis of kidney function using 99m technetium mercaptoacetyltriglycine (MAG3)].

    PubMed

    Erpenbach, K; Ebert, A; Wieler, H

    1991-03-01

    Renal scintigraphy and clearance measurement are indispensable in nephro-urologic disorders. A continuous series of 103 sequential scintigraphies and clearance measurements were performed with the new technetium-labelled agent MAG3 (Gamma-kamera, Phillips Tomo Diagnost) and 131I-orthohippuric acid (OIH) using the Oberhausen method (Nucleopan, Siemens). The time-activity curves obtained with the two radionuclides agreed exactly. Reaching a tubular excretion rate of nearly 90%, the clearance of MAG3 differed by no more than 6% from the OIH clearance in 95% of the cases. The factor between clearances of the two radionuclides was determined by means of a commercially available software according to the Oberhausen method and amounted to 0.59 +/- 0.09. The favorable physical properties and high activity of MAG3 permit exact examination of tubular function and better assessment of renal morphology than hippuran-labelled radionuclides. The low radiation dose combined with a better spatial resolution, especially, the constant availability in a nuclear medicine department should give the preference to MAG3.

  2. Comparison of Tc-99m maraciclatide and Tc-99m sestamibi molecular breast imaging in patients with suspected breast cancer.

    PubMed

    O'Connor, Michael K; Morrow, Melissa M B; Hunt, Katie N; Boughey, Judy C; Wahner-Roedler, Dietlind L; Conners, Amy Lynn; Rhodes, Deborah J; Hruska, Carrie B

    2017-12-01

    Molecular breast imaging (MBI) performed with 99m Tc sestamibi has been shown to be a valuable technique for the detection of breast cancer. Alternative radiotracers such as 99m Tc maraciclatide may offer improved uptake in breast lesions. The purpose of this study was to compare relative performance of 99m Tc sestamibi and 99m Tc maraciclatide in patients with suspected breast cancer, using a high-resolution dedicated gamma camera for MBI. Women with breast lesions suspicious for malignancy were recruited to undergo two MBI examinations-one with 99m Tc sestamibi and one with 99m Tc maraciclatide. A radiologist interpreted MBI studies in a randomized, blinded fashion to assign an assessment score (1-5) and measured lesion size. Lesion-to-background (L/B) ratio was measured with region-of-interest analysis. Among 39 analyzable patients, 21 malignant tumors were identified in 21 patients. Eighteen of 21 tumors (86%) were seen on 99m Tc sestamibi MBI and 19 of 21 (90%) were seen on 99m Tc maraciclatide MBI (p = 1). Tumor extent measured with both radiopharmaceuticals correlated strongly with pathologic size ( 99m Tc sestamibi, r = 0.84; 99m Tc maraciclatide, r = 0.81). The L/B ratio in detected breast cancers was similar for the two radiopharmaceuticals: 1.55 ± 0.36 (mean ± S.D.) for 99m Tc sestamibi and 1.62 ± 0.37 (mean ± S.D.) for 99m Tc maraciclatide (p = 0.53). No correlation was found between the L/B ratio and molecular subtype for 99m Tc sestamibi (r s  = 0.12, p = 0.63) or 99m Tc maraciclatide (r s  = -0.12, p = 0.64). Of 20 benign lesions, 10 (50%) were seen on 99m Tc sestamibi and 9 of 20 (45%) were seen on 99m Tc maraciclatide images (p = 0.1). The average L/B ratio for benign lesions was 1.34 ±0.40 (mean ±S.D.) for 99m Tc sestamibi and 1.41 ±0.52 (mean ±S.D.) for 99m Tc maraciclatide (p = 0.75). Overall diagnostic performance was similar for both radiopharmaceuticals. AUC from ROC

  3. 99mTechnetium and methylene blue guided pulmonary nodules resections: preliminary British experience.

    PubMed

    Nardini, Marco; Bilancia, Rocco; Paul, Ian; Jayakumar, Shruti; Papoulidis, Pavlos; ElSaegh, Mohamed; Hartley, Richard; Richardson, Mark; Misra, Pankash; Migliore, Marcello; Dunning, Joel

    2018-02-01

    Subcentimetre pulmonary nodules can be challenging to locate either during video-assisted thoracoscopic surgery (VATS) or by open techniques. In an era of increasing computed tomography scan availability the number of nodules that are identified that are suspicious for malignancy is rising, and thoracic surgeons require a reliable method to locate these nodules intraoperatively. Our aim was to evaluate, for the first time in the UK, resection of pulmonary nodules using radioactive dye labelling. Local research ethics approval was obtained and the study was submitted to the Integrated Research Application System (IRAS). All data were prospectively collected in our dedicated thoracic surgical database and analyzed at the conclusion of the study. This represents a consecutive series of patients, from January 2016 and until April 2017, who underwent this procedure at our institution: James Cook University Hospital, Middlesbrough, United Kingdom. The primary outcome measured was successful resection rate of the target nodules. Twenty-three patients underwent radiolabeled excision of pulmonary nodules, their average age was 61 years (range, 28-79 years), 13 women and 10 men. The average maximum diameter of the nodule was 8 mm (range, 3-16 mm). All patients underwent successful excision of the target lesion (success rate 100%). One patient (4.3%) sustained pneumothorax following the CT-guided injection of the radio-labelled dye and this required chest drainage prior to general anesthesia. We conclude that technetium guided pulmonary nodule resection is a very reliable method for localization and resection of subcentimetre nodules which may be otherwise be difficult to identify.

  4. 99mTechnetium and methylene blue guided pulmonary nodules resections: preliminary British experience

    PubMed Central

    Bilancia, Rocco; Paul, Ian; Jayakumar, Shruti; Papoulidis, Pavlos; ElSaegh, Mohamed; Hartley, Richard; Richardson, Mark; Misra, Pankash; Migliore, Marcello; Dunning, Joel

    2018-01-01

    Background Subcentimetre pulmonary nodules can be challenging to locate either during video-assisted thoracoscopic surgery (VATS) or by open techniques. In an era of increasing computed tomography scan availability the number of nodules that are identified that are suspicious for malignancy is rising, and thoracic surgeons require a reliable method to locate these nodules intraoperatively. Methods Our aim was to evaluate, for the first time in the UK, resection of pulmonary nodules using radioactive dye labelling. Local research ethics approval was obtained and the study was submitted to the Integrated Research Application System (IRAS). All data were prospectively collected in our dedicated thoracic surgical database and analyzed at the conclusion of the study. This represents a consecutive series of patients, from January 2016 and until April 2017, who underwent this procedure at our institution: James Cook University Hospital, Middlesbrough, United Kingdom. The primary outcome measured was successful resection rate of the target nodules. Results Twenty-three patients underwent radiolabeled excision of pulmonary nodules, their average age was 61 years (range, 28–79 years), 13 women and 10 men. The average maximum diameter of the nodule was 8 mm (range, 3–16 mm). All patients underwent successful excision of the target lesion (success rate 100%). One patient (4.3%) sustained pneumothorax following the CT-guided injection of the radio-labelled dye and this required chest drainage prior to general anesthesia. Conclusions We conclude that technetium guided pulmonary nodule resection is a very reliable method for localization and resection of subcentimetre nodules which may be otherwise be difficult to identify. PMID:29607175

  5. InGaAsP/InP-air-aperture microcavities for single-photon sources at 1.55-μm telecommunication band

    NASA Astrophysics Data System (ADS)

    Guo, Sijie; Zheng, Yanzhen; Weng, Zhuo; Yao, Haicheng; Ju, Yuhao; Zhang, Lei; Ren, Zhilei; Gao, Ruoyao; Wang, Zhiming M.; Song, Hai-Zhi

    2016-11-01

    InGaAsP/InP-air-aperture micropillar cavities are proposed to serve as 1.55-μm single photon sources, which are indispensable in silica-fiber based quantum information processing. Owing to air-apertures introduced to InP layers, and adiabatically tapered distributed Bragg-reflector structures used in the central cavity layers, the pillar diameters can be less than 1 μm, achieving mode volume as small as (λ/n)3, and the quality factors are more than 104 - 105, sufficient to increase the quantum dot emission rate for 100 times and create strong coupling between the optical mode and the 1.55- μm InAs/InP quantum dot emitter. The mode wavelengths and quality factors are found weakly changing with the cavity size and the deviation from the ideal shape, indicating the robustness against the imperfection of the fabrication technique. The fabrication, simply epitaxial growth, dry and chemical etching, is a damage-free and monolithic process, which is advantageous over previous hybrid cavities. The above properties satisfy the requirements of efficient, photonindistinguishable and coherent 1.55-μm quantum dot single photon sources, so the proposed InGaAsP/InP-air-aperture micropillar cavities are prospective candidates for quantum information devices at telecommunication band.

  6. Experimental entangled photon pair generation using crystals with parallel optical axes

    NASA Astrophysics Data System (ADS)

    Villar, Aitor; Lohrmann, Alexander; Ling, Alexander

    2018-05-01

    We present an optical design where polarization-entangled photon pairs are generated within two $\\beta$-Barium Borate crystals whose optical axes are parallel. This design increases the spatial mode overlap of the emitted photon pairs enhancing single mode collection without the need for additional spatial walk-off compensators. The observed photon pair rate is at least 65000 pairs/s/mW with a quantum state fidelity of 99.53$\\pm$0.22% when pumped with an elliptical spatial profile.

  7. Direct detection of a single photon by humans

    PubMed Central

    Tinsley, Jonathan N.; Molodtsov, Maxim I.; Prevedel, Robert; Wartmann, David; Espigulé-Pons, Jofre; Lauwers, Mattias; Vaziri, Alipasha

    2016-01-01

    Despite investigations for over 70 years, the absolute limits of human vision have remained unclear. Rod cells respond to individual photons, yet whether a single-photon incident on the eye can be perceived by a human subject has remained a fundamental open question. Here we report that humans can detect a single-photon incident on the cornea with a probability significantly above chance. This was achieved by implementing a combination of a psychophysics procedure with a quantum light source that can generate single-photon states of light. We further discover that the probability of reporting a single photon is modulated by the presence of an earlier photon, suggesting a priming process that temporarily enhances the effective gain of the visual system on the timescale of seconds. PMID:27434854

  8. (99m)Tc(CO)3(NTA): a (99m)Tc renal tracer with pharmacokinetic properties comparable to those of (131)I-OIH in healthy volunteers.

    PubMed

    Taylor, Andrew T; Lipowska, Malgorzata; Marzilli, Luigi G

    2010-03-01

    Studies in rats showed that the pharmacokinetics of the tricarbonyl core radiopharmaceutical (99m)Tc(CO)(3)-nitrilotriacetic acid, (99m)Tc(CO)(3)(NTA), were essentially identical to those of (131)I ortho-iodohippuran ((131)I-OIH), the clinical gold standard for the measurement of effective renal plasma flow. Our objective was to compare the pharmacokinetics of these 2 tracers in healthy volunteers. (99m)Tc(CO)(3)(NTA) was prepared with commercially available NTA and a commercially available kit and isolated by reversed-phase high-performance liquid chromatography. Approximately 74 MBq (2 mCi) of (99m)Tc(CO)(3)(NTA) were coinjected with 9.25 MBq (250 microCi) of (131)I-OIH in 9 volunteers, and simultaneous imaging of each tracer was performed for 24 min. Plasma clearances were determined from 8 blood samples obtained 3-90 min after injection using the single-injection, 2-compartment model. Plasma protein binding, red cell uptake, and percentage injected dose in the urine at 30 and 180 min were determined. There was no difference in the plasma clearances of (99m)Tc(CO)(3)(NTA) and (131)I-OIH, 475 +/- 105 mL/min versus 472 +/- 108 mL/min, respectively. The plasma protein binding and red cell uptake of (99m)Tc(CO)(3)(NTA) were 43% +/- 5% and 9% +/- 6%, respectively; both values were significantly lower (P < 0.001) than the plasma protein binding (75% +/- 3%) and red cell uptake (17% +/- 5%) of (131)I-OIH. There was no significant difference in the percentage injected dose recovered in the urine at 30 min and at 3 h; for comparison, the percentage dose in the urine at 3 h was 91% +/- 4% for (99m)Tc(CO)(3)(NTA) and 91% +/- 6% for (131)I-OIH (P = 0.96). Image quality with (99m)Tc(CO)(3)(NTA) was excellent, and the renogram parameters were similar to those of (131)I-OIH. Preliminary results in healthy volunteers suggest that the pharmacokinetic behavior of (99m)Tc(CO)(3)(NTA) is comparable to that of (131)I-OIH.

  9. Absent 99mTc-MIBI Uptake in the Thyroid Gland during Early Phase of Parathyroid Scintigraphy in Patients with Primary and Secondary Hyperparathyroidism.

    PubMed

    Jovanovska, Anamarija; Stoilovska, Bojana; Mileva, Magdalena; Miladinova, Daniela; Majstorov, Venjamin; Ugrinska, Ana

    2018-05-20

    Thyroid uptake of technetium-99m methoxyisobutylisonitrile ( 99m Tc-MIBI) during parathyroid scintigraphy can be affected by various conditions. To evaluate the frequency of absent 99m Tc-MIBI uptake by the thyroid gland in the early phase of dual-phase parathyroid scintigraphy. The early planar images of dual phase Tc 99m MIBI parathyroid scintigraphy from 217 patients performed between 2014 and 2017 were retrospectively analysed. Patients were divided into two groups. The first group included 147 patients with primary hyperparathyroidism and the second group included 70 patients with chronic renal failure. Patient records, laboratory and ultrasonographic data were analysed in all patients. Descriptive statistic was used for data analysis. Out of all patients in the first group, 18 patients (12.24%) showed absent thyroid uptake. Thyroidectomy was performed in 44.4% of these patients, and the rest of them had some thyroid disease. Only one patient had no thyroid or another chronic disease. In the second group, 8 patients (11.42%) presented with absent thyroid uptake of MIBI. Among them, 5 patients had no history of thyroid disease and had been on hemodialysis programme, and 3 patients had hypothyroidism. Absent 99m Tc-MIBI uptake in the thyroid during the early phase of parathyroid scintigraphy is most frequently related to thyroid disease. A small proportion of patients with chronic renal failure can present with absent 99m Tc-MIBI uptake in the thyroid as well. The mechanism for this alteration is still unclear and needs further investigation.

  10. Simultaneous Tc-99m and I-123 dual-radionuclide imaging with a solid-state detector-based brain-SPECT system and energy-based scatter correction.

    PubMed

    Takeuchi, Wataru; Suzuki, Atsuro; Shiga, Tohru; Kubo, Naoki; Morimoto, Yuichi; Ueno, Yuichiro; Kobashi, Keiji; Umegaki, Kikuo; Tamaki, Nagara

    2016-12-01

    A brain single-photon emission computed tomography (SPECT) system using cadmium telluride (CdTe) solid-state detectors was previously developed. This CdTe-SPECT system is suitable for simultaneous dual-radionuclide imaging due to its fine energy resolution (6.6 %). However, the problems of down-scatter and low-energy tail due to the spectral characteristics of a pixelated solid-state detector should be addressed. The objective of this work was to develop a system for simultaneous Tc-99m and I-123 brain studies and evaluate its accuracy. A scatter correction method using five energy windows (FiveEWs) was developed. The windows are Tc-lower, Tc-main, shared sub-window of Tc-upper and I-lower, I-main, and I-upper. This FiveEW method uses pre-measured responses for primary gamma rays from each radionuclide to compensate for the overestimation of scatter by the triple-energy window method that is used. Two phantom experiments and a healthy volunteer experiment were conducted using the CdTe-SPECT system. A cylindrical phantom and a six-compartment phantom with five different mixtures of Tc-99m and I-123 and a cold one were scanned. The quantitative accuracy was evaluated using 18 regions of interest for each phantom. In the volunteer study, five healthy volunteers were injected with Tc-99m human serum albumin diethylene triamine pentaacetic acid (HSA-D) and scanned (single acquisition). They were then injected with I-123 N-isopropyl-4-iodoamphetamine hydrochloride (IMP) and scanned again (dual acquisition). The counts of the Tc-99m images for the single and dual acquisitions were compared. In the cylindrical phantom experiments, the percentage difference (PD) between the single and dual acquisitions was 5.7 ± 4.0 % (mean ± standard deviation). In the six-compartment phantom experiment, the PDs between measured and injected activity for Tc-99m and I-123 were 14.4 ± 11.0 and 2.3 ± 1.8 %, respectively. In the volunteer study, the PD between the single

  11. High energy, single-polarized, single-transverse-mode, nanosecond pulses generated by a multi-stage Yb-doped photonic crystal fiber amplifier

    NASA Astrophysics Data System (ADS)

    Shen, Xinglai; Zhang, Haitao; Hao, He; Li, Dan; Li, Qinghua; Yan, Ping; Gong, Mali

    2015-06-01

    We report the construction of a cascaded fiber amplifier where a 40-μm-core-diameter photonic crystal fiber is utilized in the main amplifier stage. Single-transverse-mode, linearly-polarized, 7.5 ns pulses with 1.5 mJ energy, 123 kW peak power and 10 nm spectral bandwidth centered at 1062 nm are generated. To our knowledge, the pulse energy we obtain is the highest from 40-μm-core-diameter photonic crystal fibers, and also the highest for long pulses (>1 ns) with linear polarization and single transverse mode.

  12. Technetium and rhenium pentacarbonyl complexes with C₂ and C₁₁ ω-isocyanocarboxylic acid esters.

    PubMed

    Miroslavov, Alexander E; Polotskii, Yuriy S; Gurzhiy, Vladislav V; Ivanov, Alexander Yu; Lumpov, Alexander A; Tyupina, Margarita Yu; Sidorenko, Georgy V; Tolstoy, Peter M; Maltsev, Daniil A; Suglobov, Dmitry N

    2014-08-04

    Technetium(I) and rhenium(I) pentacarbonyl complexes with ethyl 2-isocyanoacetate and methyl 11-isocyanoundecanoate, [M(CO)5(CNCH2COOEt)]ClO4 (M = Tc (1) and Re (2)) and [M(CO)5(CN(CH2)10COOMe)]ClO4 (M = Tc (3) and Re (4)), were prepared and characterized by IR, (1)H NMR, and (13)C{(1)H} NMR spectroscopy. The crystal structures of 1 and 2 were determined using single-crystal X-ray diffraction. The kinetics of thermal decarbonylation of technetium complexes 1 and 3 in ethylene glycol was studied by IR spectroscopy. The rate constants and activation parameters of this reaction were determined and compared with those for [Tc(CO)6](+). It was found that rhenium complexes 2 and 4 were stable with respect to thermal decarbonylation. Histidine challenge reaction of complexes 1 and 2 in phosphate buffer was examined by IR spectroscopy. In the presence of histidine, the rhenium pentacarbonyl isocyanide complex partially decomposes to form an unidentified yellow precipitate. Technetium analogue 1 is more stable under these conditions.

  13. Integrated spatial multiplexing of heralded single-photon sources

    PubMed Central

    Collins, M.J.; Xiong, C.; Rey, I.H.; Vo, T.D.; He, J.; Shahnia, S.; Reardon, C.; Krauss, T.F.; Steel, M.J.; Clark, A.S.; Eggleton, B.J.

    2013-01-01

    The non-deterministic nature of photon sources is a key limitation for single-photon quantum processors. Spatial multiplexing overcomes this by enhancing the heralded single-photon yield without enhancing the output noise. Here the intrinsic statistical limit of an individual source is surpassed by spatially multiplexing two monolithic silicon-based correlated photon pair sources in the telecommunications band, demonstrating a 62.4% increase in the heralded single-photon output without an increase in unwanted multipair generation. We further demonstrate the scalability of this scheme by multiplexing photons generated in two waveguides pumped via an integrated coupler with a 63.1% increase in the heralded photon rate. This demonstration paves the way for a scalable architecture for multiplexing many photon sources in a compact integrated platform and achieving efficient two-photon interference, required at the core of optical quantum computing and quantum communication protocols. PMID:24107840

  14. Loading a single photon into an optical cavity

    NASA Astrophysics Data System (ADS)

    Du, Shengwang; Liu, Chang; Sun, Yuan; Zhao, Luwei; Zhang, Shanchao; Loy, M. M. T.

    2015-05-01

    Confining and manipulating single photons inside a reflective optical cavity is an essential task of cavity quantum electrodynamics (CQED) for probing the quantum nature of light quanta. Such systems are also elementary building blocks for many protocols of quantum network, where remote cavity quantum nodes are coupled through flying photons. The connectivity and scalability of such a quantum network strongly depends on the efficiency of loading a single photon into cavity. In this work we demonstrate that a single photon with an optimal temporal waveform can be efficiently loaded into a cavity. Using heralded narrow-band single photons with exponential growth wave packet whose time constant matches the photon lifetime in the cavity, we demonstrate a loading efficiency of more than 87 percent from free space to a single-sided Fabry-Perot cavity. Our result and approach may enable promising applications in realizing large-scale CQED-based quantum networks. The work was supported by the Hong Kong RGC (Project No. 601411).

  15. Potential Ways to Address Shortage Situations of 99Mo/99mTc.

    PubMed

    Filzen, Leah M; Ellingson, Lacey R; Paulsen, Andrew M; Hung, Joseph C

    2017-03-01

    99m Tc, the most common radioisotope used in nuclear medicine, is produced in a nuclear reactor from the decay of 99 Mo. There are only a few aging nuclear reactors around the world that produce 99 Mo, and one of the major contributors, the National Research Universal (Canada), ceased production on October 31, 2016. The National Research Universal produced approximately 40% of the world's 99 Mo supply, so with its shut down, shortages of 99 Mo/ 99m Tc are expected. Methods: Nuclear pharmacies and nuclear medicine departments throughout the United States were contacted and asked to provide their strategies for coping with a shortage of 99 Mo/ 99m Tc. Each of these strategies was evaluated on the basis of its effectiveness for conserving 99m Tc while still meeting the needs of the patients. Results: From the responses, the following 6 categories of strategies, in order of importance, were compiled: contractual agreements with commercial nuclear pharmacies, alternative imaging protocols, changes in imaging schedules, software use, generator management, and reduction of ordered doses or elimination of backup doses. Conclusion: The supply chain of 99 Mo/ 99m Tc is quite fragile; therefore, being aware of the most appropriate coping strategies is crucial. It is essential to build a strong collaboration between the nuclear pharmacy and nuclear medicine department during a shortage situation. With both nuclear medicine departments and nuclear pharmacies implementing viable strategies, such as the ones proposed, the amount of 99m Tc available during a shortage situation can be maximized. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  16. Diamond-based single-photon emitters

    NASA Astrophysics Data System (ADS)

    Aharonovich, I.; Castelletto, S.; Simpson, D. A.; Su, C.-H.; Greentree, A. D.; Prawer, S.

    2011-07-01

    The exploitation of emerging quantum technologies requires efficient fabrication of key building blocks. Sources of single photons are extremely important across many applications as they can serve as vectors for quantum information—thereby allowing long-range (perhaps even global-scale) quantum states to be made and manipulated for tasks such as quantum communication or distributed quantum computation. At the single-emitter level, quantum sources also afford new possibilities in terms of nanoscopy and bio-marking. Color centers in diamond are prominent candidates to generate and manipulate quantum states of light, as they are a photostable solid-state source of single photons at room temperature. In this review, we discuss the state of the art of diamond-based single-photon emitters and highlight their fabrication methodologies. We present the experimental techniques used to characterize the quantum emitters and discuss their photophysical properties. We outline a number of applications including quantum key distribution, bio-marking and sub-diffraction imaging, where diamond-based single emitters are playing a crucial role. We conclude with a discussion of the main challenges and perspectives for employing diamond emitters in quantum information processing.

  17. Single-Photon Routing for a L-Shaped Channel

    NASA Astrophysics Data System (ADS)

    Yang, Xiong; Hou, Jiao-Jiao; Wu, Chun

    2018-02-01

    We have investigated the transport properties of a single photon scattered by a two-level atom embedded in a L-shaped waveguide, which is made of two one-dimensional (1D) semi-infinite coupled-resonator waveguides (CRWs). Single photons can be directed from one CRW to the other due to spontaneous emission of the atom. The result shows that the spontaneous emission of the TLS still routes single photon from one CRW to the other; the boundary existing makes the probability of finding single photon in a CRW could reach one. Our the scheme is helpful to construct a ring quantum networks.

  18. Experimental entangled photon pair generation using crystals with parallel optical axes.

    PubMed

    Villar, Aitor; Lohrmann, Alexander; Ling, Alexander

    2018-05-14

    We present an optical design where polarization-entangled photon pairs are generated within two β-Barium Borate crystals whose optical axes are parallel. This design increases the spatial mode overlap of the emitted photon pairs enhancing single mode collection without the need for additional spatial walk-off compensators. The observed photon pair rate is at least 65 000 pairs/s/mW with a quantum state fidelity of 99.53 ± 0.22% when pumped with an elliptical spatial profile.

  19. A single-photon fluorescence and multi-photon spectroscopic study of atherosclerotic lesions

    NASA Astrophysics Data System (ADS)

    Smith, Michael S. D.; Ko, Alex C. T.; Ridsdale, Andrew; Schattka, Bernie; Pegoraro, Adrian; Hewko, Mark D.; Shiomi, Masashi; Stolow, Albert; Sowa, Michael G.

    2009-06-01

    In this study we compare the single-photon autofluorescence and multi-photon emission spectra obtained from the luminal surface of healthy segments of artery with segments where there are early atherosclerotic lesions. Arterial tissue was harvested from atherosclerosis-prone WHHL-MI rabbits (Watanabe heritable hyperlipidemic rabbit-myocardial infarction), an animal model which mimics spontaneous myocardial infarction in humans. Single photon fluorescence emission spectra of samples were acquired using a simple spectrofluorometer set-up with 400 nm excitation. Samples were also investigated using a home built multi-photon microscope based on a Ti:sapphire femto-second oscillator. The excitation wavelength was set at 800 nm with a ~100 femto-second pulse width. Epi-multi-photon spectroscopic signals were collected through a fibre-optics coupled spectrometer. While the single-photon fluorescence spectra of atherosclerotic lesions show minimal spectroscopic difference from those of healthy arterial tissue, the multi-photon spectra collected from atherosclerotic lesions show marked changes in the relative intensity of two-photon excited fluorescence (TPEF) and second-harmonic generation (SHG) signals when compared with those from healthy arterial tissue. The observed sharp increase of the relative SHG signal intensity in a plaque is in agreement with the known pathology of early lesions which have increased collagen content.

  20. [Simplicity or complexity of the radiopharmaceutical production process in the light of optimization of radiation protection of staff - 99mTc vs. 18F].

    PubMed

    Wrzesień, Małgorzata

    2018-05-22

    A radiopharmaceutical is a combination of a non-radioactive compound with a radioactive isotope. Two isotopes: technetium-99m (99mTc) and fluorine-18 (18F) are worth mentioning on the rich list of isotopes which have found numerous medical applications. Their similarity is limited only to the diagnostic area of applicability. The type and the energy of emitted radiation, the half-life and, in particular, the production method demonstrate their diversity. The 99mTc isotope is produced by a short-lived nuclide generator - molybdenum-99 (99Mo)/99mTc, while 18F is resulting from nuclear reaction occurring in a cyclotron. A relatively simple and easy handling of the 99Mo/99mTc generator, compared to the necessary use a cyclotron, seems to favor the principle of optimizing the radiological protection of personnel. The thesis on the effect of automation of both the 18F isotope production and the deoxyglucose labelling process on the optimization of radiological protection of workers compared to manual procedures during handling of radiopharmaceuticals labelled with 99Tc need to be verified. Measurements of personal dose equivalent Hp(0.07) were made in 5 nuclear medicine departments and 2 radiopharmaceuticals production centers. High-sensitivity thermoluminescent detectors (LiF: Mg, Cu, P - MCP-N) were used to determine the doses. Among the activities performed by employees of both 18F-fluorodeoxyglucose (18F-FDG) production centers and nuclear medicine departments, the manual quality control procedures and labelling of radiopharmaceuticals with 99mTc isotope manifest the greatest contribution to the recorded Hp(0.07). The simplicity of obtaining the 99mTc isotope as well as the complex, but fully automated production process of the 18F-FDG radiopharmaceutical optimize the radiation protection of workers, excluding manual procedures labelling with 99mTc or quality control of 18F-FDG. Med Pr 2018;69(3):317–327. This work is available in Open Access model and licensed

  1. Micro-pulse polarization lidar at 1.5  μm using a single superconducting nanowire single-photon detector.

    PubMed

    Qiu, Jiawei; Xia, Haiyun; Shangguan, Mingjia; Dou, Xiankang; Li, Manyi; Wang, Chong; Shang, Xiang; Lin, Shengfu; Liu, Jianjiang

    2017-11-01

    An all-fiber, eye-safe and micro-pulse polarization lidar is demonstrated with a polarization-maintaining structure, incorporating a single superconducting nanowire single-photon detector (SNSPD) at 1.5 μm. The time-division multiplexing technique is used to achieve a calibration-free optical layout. A single piece of detector is used to detect the backscatter signals at two orthogonal states in an alternative sequence. Thus, regular calibration of the two detectors in traditional polarization lidars is avoided. The signal-to-noise ratio of the lidar is guaranteed by using an SNSPD, providing high detection efficiency and low dark count noise. The linear depolarization ratio (LDR) of the urban aerosol is observed horizontally over 48 h in Hefei [N31°50'37'', E117°15'54''], when a heavy air pollution is spreading from the north to the central east of China. Phenomena of LDR bursts are detected at a location where a building is under construction. The lidar results show good agreement with the data detected from a sun photometer, a 532 nm visibility lidar, and the weather forecast information.

  2. Detection of occult infection following total joint arthroplasty using sequential technetium-99m HDP bone scintigraphy and indium-111 WBC imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, J.A.; Christie, M.J.; Sandler, M.P.

    1988-08-01

    Preoperative exclusion or confirmation of periprosthetic infection is essential for correct surgical management of patients with suspected infected joint prostheses. The sensitivity and specificity of (/sup 111/In)WBC imaging in the diagnosis of infected total joint prostheses was examined in 28 patients and compared with sequential (/sup 99m/Tc)HDP/(/sup 111/In)WBC scintigraphy and aspiration arthrography. The sensitivity of preoperative aspiration cultures was 12%, with a specificity of 81% and an accuracy of 58%. The sensitivity of (/sup 111/In)WBC imaging alone was 100%, with a specificity of 50% and an accuracy of 65%. When correlated with the bone scintigraphy and read as sequential (/supmore » 99m/Tc)HDP/(/sup 111/In)WBC imaging, the sensitivity was 88%, specificity 95%, and accuracy 93%. This study demonstrates that (/sup 111/In)WBC imaging is an extremely sensitive imaging modality for the detection of occult infection of joint prostheses. It also demonstrates the necessity of correlating (/sup 111/In)WBC images with (/sup 99m/Tc)HDP skeletal scintigraphy in the detection of occult periprosthetic infection.« less

  3. Differential Lung Uptake of 99mTc-HMPAO and 99mTc-Duramycin in the Chronic Hyperoxia Rat Model

    PubMed Central

    Clough, Anne V.; Audi, Said H.; Haworth, Steven T.; Roerig, David L.

    2015-01-01

    Noninvasive radionuclide imaging has the potential to identify and assess mechanisms involved in particular stages of lung injury which occur with acute respiratory distress syndrome, for example. Lung uptake of 99mTc-hexamethylpropyleneamine oxime (HMPAO) is reported to be partially dependent on the redox status of the lung tissue while 99mTc-duramycin, a new marker of cell injury, senses cell death via apoptosis and/or necrosis. Thus, we investigated changes in lung uptake of these agents in rat exposed to hyperoxia for prolonged periods, a common model of acute lung injury. Methods Male Sprague-Dawley rats were pre-exposed to either normoxia (21% O2) or hyperoxia (85% O2) for up to 21 days. For imaging, the rats were anesthetized, injected i.v. with either 99mTc-HMPAO or 99mTc-duramycin (37-74 MBq) and planar images were acquired using a high sensitivity modular gamma camera. Subsequently, 99mTc-macroagreggated albumin (37 MBq, diam=10-40 μm) was injected i.v., imaged, and used to define a lung region-of-interest. The lung to background ratio was used as a measure of lung uptake. Results Hyperoxia exposure resulted in a 74% increase in 99mTc-HMPAO lung uptake, which peaked at 7 days and persisted for the 21 days of exposure. 99mTc-duramycin lung uptake was also maximal at 7 days of exposure but decreased to near control levels by 21 days. The sustained elevation of 99mTc-HMPAO uptake suggests ongoing changes in lung redox status whereas cell death appears to have subsided by 21 days. Conclusion These results suggest the potential use of 99mTc-HMPAO and 99mTc-duramycin as redox and cell-death imaging biomarkers, respectively, for in vivo identification and assessment of different stages of lung injury. PMID:23086010

  4. Quantum Logic with Cavity Photons From Single Atoms.

    PubMed

    Holleczek, Annemarie; Barter, Oliver; Rubenok, Allison; Dilley, Jerome; Nisbet-Jones, Peter B R; Langfahl-Klabes, Gunnar; Marshall, Graham D; Sparrow, Chris; O'Brien, Jeremy L; Poulios, Konstantinos; Kuhn, Axel; Matthews, Jonathan C F

    2016-07-08

    We demonstrate quantum logic using narrow linewidth photons that are produced with an a priori nonprobabilistic scheme from a single ^{87}Rb atom strongly coupled to a high-finesse cavity. We use a controlled-not gate integrated into a photonic chip to entangle these photons, and we observe nonclassical correlations between photon detection events separated by periods exceeding the travel time across the chip by 3 orders of magnitude. This enables quantum technology that will use the properties of both narrow-band single photon sources and integrated quantum photonics.

  5. A pilot study evaluating 99mTc-anti-TNF-alpha scintigraphy in graves' ophtalmopathy patients with different clinical activity score.

    PubMed

    Rebelo Pinto, E dos S; Lopes, F P P L; de Souza, S A L; da Fonseca, L M B; Vaisman, M; Gutfilen, B; dos Santos Teixeira, P de F

    2013-09-01

    The present study describes the preliminary results of the use of 99mTc-anti-TNF-α scintigraphy as a new diagnostic approach to evaluate patients presenting with Graves' ophthalmopathy (GO). Patients (n=25) presenting at different inflammatory stages of GO and 10 healthy volunteers underwent 99mTc-anti-TNF-α scintigraphy. Images were obtained 15 min after the intravenous injection of 370 MBq (10 mCi) 99mTc-anti-TNF-α. Planar images were obtained in a 256×256 matrix (each lasting 5 min) and single photon emission computed tomography (SPECT) scan lasting 13 min. Regions of interest (ROI) were drawn on the orbit and cerebral hemispheres. The uptake of 99m Tc-anti-TNF-α in these regions was compared and positive scintigraphy established when the ROI was >2.5. In addition, uptake for each positive exam was scored as either slight (2.6-5.1), moderate (5.2-7.6), or high (>7.6). In this pilot study, 69 orbits were evaluated (1 patient had only 1 eye), and 27 had a positive CAS (≥3/7). Scintigraphies were positive in 38 orbits. Comparing the results of the exams with CAS, a high sensitivity and negative predictive values were determined for scintigraphy (96.3% and 96.7%, respectively). However, the specificity and the positive predictive values were 71.4% and 68.4%, respectively, with an accuracy of 81.2%. The exclusion of examinations that were slightly positive from the analysis resulted in an improvement in test accuracy (95.5%). The preliminary results suggest that 99mTc-anti-TNF-α scintigraphy is a promising procedure for the evaluation of active orbital inflammation in GO. © Georg Thieme Verlag KG Stuttgart · New York.

  6. Single colloidal quantum dots as sources of single photons for quantum cryptography

    NASA Astrophysics Data System (ADS)

    Pisanello, Ferruccio; Qualtieri, Antonio; Leménager, Godefroy; Martiradonna, Luigi; Stomeo, Tiziana; Cingolani, Roberto; Bramati, Alberto; De Vittorio, Massimo

    2011-02-01

    Colloidal nanocrystals, i.e. quantum dots synthesized trough wet-chemistry approaches, are promising nanoparticles for photonic applications and, remarkably, their quantum nature makes them very promising for single photon emission at room temperature. In this work we describe two approaches to engineer the emission properties of these nanoemitters in terms of radiative lifetime and photon polarization, drawing a viable strategy for their exploitation as room-temperature single photon sources for quantum information and quantum telecommunications.

  7. Remote-loading labeling of liposomes with (99m)Tc-BMEDA and its stability evaluation: effects of lipid formulation and pH/chemical gradient.

    PubMed

    Li, Shihong; Goins, Beth; Phillips, William T; Bao, Ande

    2011-03-01

    Efficient, convenient, and stable radiolabeling plays a critical role for the monitoring of liposome behavior via either blood sampling, organ distribution, or noninvasive nuclear imaging. The direct labeling of liposome-carrying drugs without any prior modification undoubtedly is convenient and optimal for liposomal drug testing. In this article, we investigated the effect of various lipid formulations and pH/chemical gradients on the radiolabeling efficiency and entrapment stability of technetium-99m ((99m)Tc) remotely loaded into liposomes, using (99m)Tc-N,N-bis(2-mercaptoethyl)-N',N'-diethyl-ethylenediamine ((99m)Tc-BMEDA) complex. The tested liposomes either contained unsaturated lipid or possessed various surface charges. (99m)Tc could be efficiently loaded into various premanufactured liposomes containing either an ammonium sulfate pH, citrate pH, or glutathione (GSH) chemical gradient. (99m)Tc-entrapment stabilities of these liposomes in phosphate-buffered saline (PBS; pH 7.4) buffer at 25°C were mainly dependent on the pH/chemical gradient, but not lipid formulation. Stability sequence was ammonium sulfate pH-gradient>citrate pH-gradient>GSH-gradient. Stabilities of (99m)Tc-liposomes in 50% fetal bovine serum (FBS)/PBS (pH 7.4) buffer at 37°C are dependent on both lipid formulation and pH/chemical gradient. Specifically, (99m)Tc labeling of the ammonium sulfate pH-gradient liposomes were less stable in 50% FBS/PBS than in PBS, whereas noncationic liposomes with citrate pH- or GSH-gradient displayed higher stability, except that anionic citrate pH-gradient liposomes showed no stability difference in these two media. Cationic liposomes aggregated in 50% FBS/PBS, forming a new discrete fraction with larger particle sizes. These in vitro characterization results have indicated the optimism of using (99m)Tc-BMEDA for labeling pH/GSH gradient liposomes without the requirement of modifying lipid formulation for liposomal therapeutic-agent development.

  8. Introduction of an 8-Aminooctanoic Acid Linker Enhances the melanoma uptake of Tc-99m-labeled Lactam Bridge-Cyclized Alpha-MSH Peptide

    PubMed Central

    Guo, Haixun; Miao, Yubin

    2015-01-01

    The purpose of this study was to examine the effects of amino acid, hydrocarbon and polyethylene glycol (PEG) linkers on melanoma targeting and imaging properties of 99mTc-labeled lactam bridge-cyclized HYNIC-linker-Nle-CycMSHhex {hydrazinonicotinamide-linker-Nle-c[Asp-His-DPhe-Arg-Trp-Lys]-CONH2} peptides. Methods four novel peptides {HYNIC-GGGNle-CycMSHhex, HYNIC-GSGNle-CycMSHhex, HYNIC-PEG2Nle-CycMSHhex and HYNIC-AocNle-CycMSHhex} were designed and synthesized. The melanocortin-1 (MC1) receptor binding affinities of the peptides were determined in B16/F1 melanoma cells. The biodistribution of 99mTc(EDDA)-HYNIC-GGGNle-CycMSHhex, 99mTc(EDDA)-HYNIC-GSGNle-CycMSHhex, 99mTc(EDDA)-HYNIC-PEG2Nle-CycMSHhex and 99mTc(EDDA)-HYNIC-AocNle-CycMSHhex were determined in B16/F1 melanoma-bearing C57 mice at 2 h post-injection to select a lead peptide for further evaluation. The melanoma targeting and imaging properties of 99mTc(EDDA)-HYNIC-AocNle-CycMSHhex were further examined because of its high melanoma uptake. Results The IC50 values of HYNIC-GGGNle-CycMSHhex, HYNIC-GSGNle-CycMSHhex, HYNIC-PEG2Nle-CycMSHhex, and HYNIC-AocNle-CycMSHhex were 0.7 ± 0.1, 0.8 ± 0.09, 0.4 ± 0.08, and 0.3 ± 0.06 nM in B16/F1 melanoma cells, respectively. Among these four 99mTc-labeled peptides, 99mTc(EDDA)-HYNIC-AocNle-CycMSHhex displayed the highest melanoma uptake (22.3 ± 1.72% ID/g) at 2 h post-injection. 99mTc(EDDA)-HYNIC-AocNle-CycMSHhex exhibited high tumor to normal organ uptake ratios except for the kidneys. The tumor/kidney uptake ratios of 99mTc(EDDA)-HYNIC-AocNle-CycMSHhex were 3.29, 3.63 and 6.78 at 2, 4 and 24 h post-injection. The melanoma lesions were clearly visualized by single photon emission computed tomography (SPECT)/CT using 99mTc(EDDA)-HYNIC-AocNle-CycMSHhex as an imaging probe at 2 h post-injection. Conclusion High melanoma uptake and fast urinary clearance of 99mTc(EDDA)-HYNIC-AocNle-CycMSHhex highlighted its potential for metastatic melanoma detection in the future

  9. Electro-optic routing of photons from a single quantum dot in photonic integrated circuits

    NASA Astrophysics Data System (ADS)

    Midolo, Leonardo; Hansen, Sofie L.; Zhang, Weili; Papon, Camille; Schott, Rüdiger; Ludwig, Arne; Wieck, Andreas D.; Lodahl, Peter; Stobbe, Søren

    2017-12-01

    Recent breakthroughs in solid-state photonic quantum technologies enable generating and detecting single photons with near-unity efficiency as required for a range of photonic quantum technologies. The lack of methods to simultaneously generate and control photons within the same chip, however, has formed a main obstacle to achieving efficient multi-qubit gates and to harness the advantages of chip-scale quantum photonics. Here we propose and demonstrate an integrated voltage-controlled phase shifter based on the electro-optic effect in suspended photonic waveguides with embedded quantum emitters. The phase control allows building a compact Mach-Zehnder interferometer with two orthogonal arms, taking advantage of the anisotropic electro-optic response in gallium arsenide. Photons emitted by single self-assembled quantum dots can be actively routed into the two outputs of the interferometer. These results, together with the observed sub-microsecond response time, constitute a significant step towards chip-scale single-photon-source de-multiplexing, fiber-loop boson sampling, and linear optical quantum computing.

  10. A photon-photon quantum gate based on a single atom in an optical resonator.

    PubMed

    Hacker, Bastian; Welte, Stephan; Rempe, Gerhard; Ritter, Stephan

    2016-08-11

    That two photons pass each other undisturbed in free space is ideal for the faithful transmission of information, but prohibits an interaction between the photons. Such an interaction is, however, required for a plethora of applications in optical quantum information processing. The long-standing challenge here is to realize a deterministic photon-photon gate, that is, a mutually controlled logic operation on the quantum states of the photons. This requires an interaction so strong that each of the two photons can shift the other's phase by π radians. For polarization qubits, this amounts to the conditional flipping of one photon's polarization to an orthogonal state. So far, only probabilistic gates based on linear optics and photon detectors have been realized, because "no known or foreseen material has an optical nonlinearity strong enough to implement this conditional phase shift''. Meanwhile, tremendous progress in the development of quantum-nonlinear systems has opened up new possibilities for single-photon experiments. Platforms range from Rydberg blockade in atomic ensembles to single-atom cavity quantum electrodynamics. Applications such as single-photon switches and transistors, two-photon gateways, nondestructive photon detectors, photon routers and nonlinear phase shifters have been demonstrated, but none of them with the ideal information carriers: optical qubits in discriminable modes. Here we use the strong light-matter coupling provided by a single atom in a high-finesse optical resonator to realize the Duan-Kimble protocol of a universal controlled phase flip (π phase shift) photon-photon quantum gate. We achieve an average gate fidelity of (76.2 ± 3.6) per cent and specifically demonstrate the capability of conditional polarization flipping as well as entanglement generation between independent input photons. This photon-photon quantum gate is a universal quantum logic element, and therefore could perform most existing two-photon operations

  11. Atom-atom entanglement by single-photon detection.

    PubMed

    Slodička, L; Hétet, G; Röck, N; Schindler, P; Hennrich, M; Blatt, R

    2013-02-22

    A scheme for entangling distant atoms is realized, as proposed in the seminal paper by [C. Cabrillo et al., Phys. Rev. A 59, 1025 (1999)]. The protocol is based on quantum interference and detection of a single photon scattered from two effectively one meter distant laser cooled and trapped atomic ions. The detection of a single photon heralds entanglement of two internal states of the trapped ions with high rate and with a fidelity limited mostly by atomic motion. Control of the entangled state phase is demonstrated by changing the path length of the single-photon interferometer.

  12. Endocrine radionuclide scintigraphy with fusion single photon emission computed tomography/computed tomography

    PubMed Central

    Wong, Ka-Kit; Gandhi, Arpit; Viglianti, Benjamin L; Fig, Lorraine M; Rubello, Domenico; Gross, Milton D

    2016-01-01

    AIM: To review the benefits of single photon emission computed tomography (SPECT)/computed tomography (CT) hybrid imaging for diagnosis of various endocrine disorders. METHODS: We performed MEDLINE and PubMed searches using the terms: “SPECT/CT”; “functional anatomic mapping”; “transmission emission tomography”; “parathyroid adenoma”; “thyroid cancer”; “neuroendocrine tumor”; “adrenal”; “pheochromocytoma”; “paraganglioma”; in order to identify relevant articles published in English during the years 2003 to 2015. Reference lists from the articles were reviewed to identify additional pertinent articles. Retrieved manuscripts (case reports, reviews, meta-analyses and abstracts) concerning the application of SPECT/CT to endocrine imaging were analyzed to provide a descriptive synthesis of the utility of this technology. RESULTS: The emergence of hybrid SPECT/CT camera technology now allows simultaneous acquisition of combined multi-modality imaging, with seamless fusion of three-dimensional volume datasets. The usefulness of combining functional information to depict the bio-distribution of radiotracers that map cellular processes of the endocrine system and tumors of endocrine origin, with anatomy derived from CT, has improved the diagnostic capability of scintigraphy for a range of disorders of endocrine gland function. The literature describes benefits of SPECT/CT for 99mTc-sestamibi parathyroid scintigraphy and 99mTc-pertechnetate thyroid scintigraphy, 123I- or 131I-radioiodine for staging of differentiated thyroid carcinoma, 111In- and 99mTc- labeled somatostatin receptor analogues for detection of neuroendocrine tumors, 131I-norcholesterol (NP-59) scans for assessment of adrenal cortical hyperfunction, and 123I- or 131I-metaiodobenzylguanidine imaging for evaluation of pheochromocytoma and paraganglioma. CONCLUSION: SPECT/CT exploits the synergism between the functional information from radiopharmaceutical imaging and anatomy

  13. Sentinel node detection in cervical cancer with (99m)Tc-phytate.

    PubMed

    Silva, Lucas B; Silva-Filho, Agnaldo L; Traiman, Paulo; Triginelli, Sérgio A; de Lima, Carla Flávia; Siqueira, Cristiano Ferrari; Barroso, Adelanir; Rossi, Telma Maria F F; Pedrosa, Moises Salgado; Miranda, Dairton; Melo, José Renan Cunha

    2005-05-01

    The aim of this study was to investigate the feasibility of sentinel lymph node (SLN) identification using radioisotopic lymphatic mapping with technetium-99 m-labeled phytate in patients undergoing radical hysterectomy with pelvic lymphadenectomy for treatment of early cervical cancer. Between July 2001 and February 2003, 56 patients with cervical cancer FIGO stage I (n = 53) or stage II (n = 3) underwent sentinel lymph node detection with preoperative lymphoscintigraphy ((99m)Tc-labeled phytate injected into the uterine cervix, at 3, 6, 9, and 12 o'clock, at a dose of 55-74 MBq in a volume of 0.8 ml) and intraoperative lymphatic mapping with a handheld gamma probe. Radical hysterectomy was aborted in three cases because parametrial invasion was found intraoperatively and we performed only sentinel node resection. The remaining 53 patients underwent radical hysterectomy with complete pelvic lymphadenectomy. Sentinel nodes were detected using a handheld gamma-probe and removed for pathological assessment during the abdominal radical hysterectomy and pelvic lymphadenectomy. One or more sentinel nodes were detected in 52 out of 56 eligible patients (92.8%). A total of 120 SLNs were detected by lymphoscintigraphy (mean 2.27 nodes per patient) and intraoperatively by gamma probe. Forty-four percent of SLNs were found in the external iliac area, 39% in the obturator region, 8.3% in interiliac region, and 6.7% in the common iliac area. Unilateral sentinel nodes were found in thirty-one patients (59%). The remaining 21 patients (41%) had bilateral sentinel nodes. Microscopic nodal metastases were confirmed in 17 (32%) cases. In 10 of these patients, only SLNs had metastases. The 98 sentinel nodes that were negative on hematoxylin and eosin were submitted to cytokeratin immunohistochemical analysis. Five (5.1%) micrometastases were identified with this technique. The sensitivity of the sentinel node was 82.3% (CI 95% = 56.6-96.2) and the negative predictive value was 92

  14. Use of blood-pool imaging in evaluation of diffuse activity patterns in technetium-99m pyrophosphate myocardial scintigraphy.

    PubMed

    Cowley, M J; Mantle, J A; Rogers, W J; Russell, R O; Rackley, C E; Logic, J R

    1979-06-01

    It has been suggested that diffuse Tc-99m pyrophosphate precordial activity may be due to persistent blood-pool activity in routine delayed views during myocardial imaging. To answer this question, we reviewed myocardial scintigrams recorded 60--90 min following the injection of 12--15 mCi of Tc-99m pyrophosphate for the presence of diffuse precordial activity, and compared these with early images of the blood pool in 265 patients. Diffuse activity in the delayed images was identified in 48 patients: in 20 with acute myocardial infarction and in 28 with no evidence of it. Comparison of these routine delayed images with early views of the blood pool revealed two types of patterns. In patients with acute infarction, 95% had delayed images that were distinguishable from blood pool either because the activity was smaller than the early blood pool, or by the presence of localized activity superimposed on diffuse activity identical to blood pool. In those without infarction, 93% had activity distribution in routine delayed views matching that in the early blood-pool images. The usefulness of the diffuse TcPPi precordial activity in myocardial infarction is improved when early blood-pool imaging is used to exclude persistence of blood-pool activity as its cause. Moreover, it does not require additional amounts of radioactivity nor complex computer processing, a feature that may be of value in the community hospital using the technique to "rule out" infarction 24--72 hr after onset of suggestive symptoms.

  15. Combined technetium radioisotope penile plethysmography and xenon washout: A technique for evaluating corpora cavernosal inflow and outflow during early tumescence

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schwartz, A.N.; Graham, M.M.

    1991-03-01

    Combined technetium radioisotope penile plethysmography and xenon washout is a new technique that measures both corporal arterial inflow and venous sinusoidal outflow during early tumescence in patients with erectile dysfunction. Fourteen patients were studied using 99mTc-RBCs to measure inflow and 133Xe or 127Xe in saline to measure outflow. Tumescence was induced by injecting papaverine intracorporally. Peak corporal rates corrected for inflow (r = 0.88) and uncorrected for outflow (r = 0.91) and change in volume over 2 min centered around peak inflow (r = 0.96) all correlated with angiography. Outflow measurements did not correlate with intracorporal resistance. Thus, outflow ratesmore » alone could not be used to predict venous sinusoidal competence. Normal inflow rate is greater than 20 ml/min; probable normal 12-20; indeterminate inflow 7-12; and abnormal inflow less than 7 ml/min. Technetium-99m radioisotope penile plethysmography and xenon washout can be performed together and both provide a method for simultaneously evaluating the relationship between corporal inflow and outflow rates in patients with erectile dysfunction.« less

  16. (99m)Tc-pyrophosphate scintigraphy for differentiating light-chain cardiac amyloidosis from the transthyretin-related familial and senile cardiac amyloidoses.

    PubMed

    Bokhari, Sabahat; Castaño, Adam; Pozniakoff, Ted; Deslisle, Susan; Latif, Farhana; Maurer, Mathew S

    2013-03-01

    Differentiating immunoglobulin light-chain (AL) from transthyretin-related cardiac amyloidoses (ATTR) is imperative given implications for prognosis, therapy, and genetic counseling. We validated the discriminatory ability of (99m)Tc-pyrophosphate ((99m)Tc-PYP) scintigraphy in AL versus ATTR. Forty-five subjects (12 AL, 16 ATTR wild type, and 17 ATTR mutants) underwent (99m)Tc-PYP planar and single-photon positive emission computed tomography cardiac imaging. Scans were performed by experienced nuclear cardiologists blinded to the subjects' cohort assignment. Cardiac retention was assessed with both a semiquantitative visual score (range, 0; no uptake to 3, diffuse uptake) and by quantitative analysis by drawing a region of interest over the heart corrected for contralateral counts and calculating a heart-to-contralateral ratio. Subjects with ATTR cardiac amyloid had a significantly higher semiquantitative cardiac visual score than the AL cohort (2.9±0.06 versus 0.8±0.27; P<0.0001) as well as a higher quantitative score (1.80±0.04 versus 1.21±0.04; P<0.0001). Using a heart-to-contralateral ratio >1.5 consistent with intensely diffuse myocardial tracer retention had a 97% sensitivity and 100% specificity with area under the curve 0.992, P<0.0001 for identifying ATTR cardiac amyloidosis. (99m)Tc-PYP cardiac imaging distinguishes AL from ATTR cardiac amyloidosis and may be a simple, widely available method for identifying subjects with ATTR cardiac amyloidosis, which should be studied in a larger prospective manner.

  17. The use of 99mTc-Al2O3 for detection of sentinel lymph nodes in cervical cancer patients

    NASA Astrophysics Data System (ADS)

    Sinilkin, I. G.; Chernov, V. I.; Lyapunov, A. Yu; Medvedeva, A. A.; Zelchan, R. V.; Chernyshova, A. L.; Kolomiets, L. A.

    2016-06-01

    The purpose of the study was to evaluate the feasibility of using 99mTc-Al2O3- based radiopharmaceutical, a novel molecular imaging agent for sentinel lymph node detection in patients with invasive cervical cancer. The study included 23 cervical cancer patients (TlaNxMx- T2bNxMx) treated at the Tomsk Cancer Research Institute. At 18 hours before surgery, 80 MBq of the 99mTc-Al2O3 were injected peritumorally, followed by single-photon emission computed tomography (SPECT) of the pelvis and intraoperative SLN identification. Twenty-seven SLNs were detected by SPECT, and 34 SLNs were identified by intraoperative gamma probe. The total number of identified SLNs per patient ranged from 1 to 3(the mean number of SLNs was 1.4 per patient). The most common site for SLN detection was the external iliac region (57.2%), followed by the internal iliac, obturator, presacral and retrosacral regions (they amounted to 14%, respectively),and the parametrial region (1%). Sensitivity in detecting SLNs was 100% for intraoperative SLN identification and 79% for SPECT image.

  18. Changing optical band structure with single photons

    NASA Astrophysics Data System (ADS)

    Albrecht, Andreas; Caneva, Tommaso; Chang, Darrick E.

    2017-11-01

    Achieving strong interactions between individual photons enables a wide variety of exciting possibilities in quantum information science and many-body physics. Cold atoms interfaced with nanophotonic structures have emerged as a platform to realize novel forms of nonlinear interactions. In particular, when atoms are coupled to a photonic crystal waveguide, long-range atomic interactions can arise that are mediated by localized atom-photon bound states. We theoretically show that in such a system, the absorption of a single photon can change the band structure for a subsequent photon. This occurs because the first photon affects the atoms in the chain in an alternating fashion, thus leading to an effective period doubling of the system and a new optical band structure for the composite atom-nanophotonic system. We demonstrate how this mechanism can be engineered to realize a single-photon switch, where the first incoming photon switches the system from being highly transmissive to highly reflective, and analyze how signatures can be observed via non-classical correlations of the outgoing photon field.

  19. Technetium-99m(Sn2+)pyrophosphate in ischemic and infarcted dog myocardium in early stages of acute coronary occlusion: histochemical and tissue-counting comparisons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bianco, J.A.; Kemper, A.J.; Taylor, A.

    1983-06-01

    We have investigated the pattern of accumulation of Tc-99m(Sn2+)pyrophosphate (Tc-99m PPi) in myocardial tissue of dogs during the early stages of acute occlusion of the left anterior descending coronary artery. Three groups were studied after: (a) 40 min occlusion followed by 6 hr reperfusion (n . 6); (b) 6 hr occlusion followed by one hour reperfusion (n . 5); and (c) 7 hr occlusion with no reperfusion (n . 4). Areas of myocardial infarction were defined with triphenyl-tetrazolium chloride (TTC) staining, and blood flow was determined with 9-mu radioactive microspheres. In Group C uptake in infarcted and peri-infarct areas wasmore » not enhanced, most likely owing to low flow. In Group B, with late reperfusion, Tc-99m PPi sequestration was increased in both infarcted and peri-infarcted tissues. In Group A, areas ischemic during occlusion but with normal flow and viability by TTC after 6 hr of reperfusion showed significant uptake of Tc-99m PPi (twice the uptake of nonischemic regions).« less

  20. Prediction of two-sample (99m)Tc-diethylene triamine pentaacetic acid plasma clearance from single-sample method.

    PubMed

    Zuo, Li; Ying-Chun; Wang, Mei; Zhang, Chun-Li; Wang, Rong-Fu; Wang, Hai-Yan

    2005-07-01

    To develop an equation to predict dual plasma sample method (DPSM) (99m)Tc-diethylene triamine pentaacetic acid ((99m)Tc-DTPA) plasma clearance from single plasma sample method (SPSM), and to clarify the condition in which DPSM can be substituted by SPSM in measurement of glomerular filtration rate (GFR). Patients with chronic kidney disease (CKD) were selected. Watson modified Christensen and Groth equation was used to calculate (99m)Tc-DTPA plasma clearance by SPSM (sGFR). The equation recommended by the Nephrourology Committee of the Society of Nuclear Medicine was used to calculate (99m)Tc-DTPA plasma clearance by DPSM (tGFR) in each patient. The difference between sGFR and tGFR was expressed as percent of the average of these two methods, and tGFR was predicted from sGFR. Plasma creatinine was measured by the kinetic picrate method, and GFR estimated by abbreviated modification of diet in renal disease (MDRD) equation (aGFR) and Cockcroft-Gault equation (cGFR) were evaluated as criteria in selection of DPSM and SPSM. Three hundred and sixty-nine patients with CKD were selected (208 male and 161 female). The average age and body weight were 51.4 +/- 15.5 years and 67.2 +/- 12.5 kg, respectively. The causes of CKD were glomerular disease, renal arterial stenosis, chronic tubulointerstitial disease, and other causes or causes unknown. The average tGFR was 62.9 +/- 36.5 ml/min/1.73 m2, ranging from 1-180 ml/min/1.73 m2. sGFR was significantly correlated with tGFR (r = 0.9194, p < 0.001), but widely scattered when tGFR <30 ml/min/1.73 m2; in contrast, then tGFR was > or =30 ml/min/1.73 m2, the difference was constant (-1.1%, 95% confidence interval -18.3%, 16.1%), and tGFR could be predicted from sGFR using the equation: predicted tGFR (ml/min/1.73 m2) = 7.4244 + 0.7318 x sGFR + 0.0022 x sGFR2 (n = 299, r2 = 0.9428, p < 0.001), and the difference decreased to 0.1%, 95% confidence interval (-15.8%, 16.0%). aGFR was better than cGFR in diagnosis of tGFR <30 ml/min/1

  1. Assessment of alveolar epithelial permeability in Behçet's disease with 99mTc-DTPA aerosol scintigraphy.

    PubMed

    Gumuser, Fikriye G; Pirildar, Timur; Batok, Dilek; Sakar, Aysin; Ruksen, Ebru; Sayit, Elvan

    2008-06-01

    Behçet's disease (BD) is a multisystem disorder characterized by vasculitis, and consists of a triad of recurrent ulcers of the oral and genital mucosa with relapsing uveitis. The prevalance of pulmonary involvement varies in the range of 1-10% in various studies and its complications are severe and life threatening. In this study, we investigated the changes of pulmonary epithelial permeability of patients with BD using technetium-99m diethylene triamine penta-acetic acid ((99m)Tc-DTPA) aerosol scintigraphy, so as to begin the therapy regimen as soon as possible. Twenty-one nonsmoking patients with BD (8 women, 13 men; mean age 38.67 +/- 8.86 years) and 15 healthy volunteer nonsmoking controls (8 women, 7 men; mean age 50.87 +/- 12.45 years) underwent (99m)Tc-DTPA aerosol inhalation scintigraphy and pulmonary function tests (PFTs). Subjects inhaled 1480 MBq of (99m)Tc-DTPA for 4 min in the supine position. Scintigraphic data were recorded dynamically (1 frame/min) in the posterior projection on a 64 x 64 matrix for a 30-min period using a double-headed gamma camera (Infinia, GE, Tirat Hacarmel, Israel) equipped with a low-energy all-purpose parallel hole collimator. Half time of (99m)Tc-DTPA clearance (T (1/2)) was calculated by placing a mono-exponential fit on the curves. Penetration index (PI) was also calculated by dividing the peripheral total counts by the sum of the peripheral and central total counts on the first minute image, in order to quantify the distribution of the inhaled aerosol. The clearance half time of (99m)Tc-DTPA radioaerosols in the BD patients (24.81 +/- 6.22 min) was faster than in the normal control group (46.53 +/- 22.41 min) (P = 0.004). There was also a significant difference between PI of the patients with BD (0.15 +/- 0.03) and that of the controls (0.21 +/- 0.06) (P = 0.002). No correlation was found between the mean T (1/2) values of (99m)Tc-DTPA clearance or the spirometric measurements in the BD patients. Penetration indices

  2. Technetium-99 cycling in maple trees: characterization of changes in chemical form.

    PubMed

    Garten, C T; Lomax, R D

    1989-08-01

    Prior field studies near an old radioactive waste disposal site at Oak Ridge, TN, indicated that following root uptake, metabolism by deciduous trees rendered 99Tc less biogeochemically mobile than expected, based on chemistry of the pertechnetate (TcO-4) anion. Subsequently, the form of technetium (Tc) in maple tree (Acer sp.) sap, leaves, wood and forest leaf litter was characterized using one or more of the following methods: dialysis, physical fractionation, chemical extraction, gel permeation chromatography, enzymatic extraction, or thin layer chromatography (TLC) on silica gel. Chromatography (Sephadex G-25) of TcO-4 incubated in vitro with tree sap showed it to behave similar to TcO-4 anion. When labeled wood and leaf tissues were processed using a tissue homogenizer, 15% and 40%, respectively, of the Tc was solubilized into phosphate buffer. Most (65% to 80%) of the solubilized Tc passing a 0.45-micron filter also passed through an ultrafiltration membrane with a nominal molecular weight cutoff of 10,000 atomic mass units (amu). A majority (72% to 80%) of the Tc in wood could be chemically removed by successive extractions with ethanol, water and weak mineral acid. These same extractants removed only 23% to 31% of the Tc from maple leaves or forest floor leaf litter. Most of the Tc in leaves and leaf litter was removed only by strongly alkaline reagents typically used to release structural polysaccharides (hemicelluloses) from plant tissues. Chromatography (Sephadex G-25) of the ethanol-water extract from wood and the alkaline extract from leaves demonstrated that Tc in these extracts was not principally TcO-4 but was complexed with molecules greater than 1000 amu. Incubations of leaf and wood homogenates with protease approximately doubled the amount of Tc released from contaminated tissues. Ultrafiltration of protease-solubilized Tc from leaves and wood showed that 40% and 93%, respectively, of the Tc was less than 10,000 amu. TLC of the less than 10

  3. 10 CFR Appendix B to Part 30 - Quantities 1 of Licensed Material Requiring Labeling

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Technetium-97m 100 Technetium-97 100 Technetium-99m 100 Technetium-99 10 Tellurium-125m 10 Tellurium-127m 10 Tellurium-127 100 Tellurium-129m 10 Tellurium-129 100 Tellurium-131m 10 Tellurium-132 10...

  4. 10 CFR Appendix B to Part 30 - Quantities 1 of Licensed Material Requiring Labeling

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Technetium-97m 100 Technetium-97 100 Technetium-99m 100 Technetium-99 10 Tellurium-125m 10 Tellurium-127m 10 Tellurium-127 100 Tellurium-129m 10 Tellurium-129 100 Tellurium-131m 10 Tellurium-132 10...

  5. Tc-99m Radiolabeled Peptide p5 + 14 is an Effective Probe for SPECT Imaging of Systemic Amyloidosis.

    PubMed

    Kennel, Stephen J; Stuckey, Alan; McWilliams-Koeppen, Helen P; Richey, Tina; Wall, Jonathan S

    2016-08-01

    Systemic peripheral amyloidosis is a rare disease in which misfolded proteins deposit in various organs. We have previously developed I-124 labeled peptide p5 + 14 as a tracer for positron emission tomography imaging of amyloid in patients. In this report, we now document the labeling efficiency, bioactivity, and stability of Tc-99m labeled p5 + 14 for single-photon emission computed tomography (SPECT) imaging of amyloidosis, validated in a mouse model of systemic amyloidosis. Radiochemical yield, purity, and biological activity of [(99m)Tc]p5 + 14 were documented by instant thin-layer chromatography (ITLC), SDS-PAGE and a quantitative amyloid fibril pulldown assay. The efficacy and stability were documented in serum amyloid protein A (AA) amyloid-bearing or wild-type (WT) control mice imaged with SPECT/X-ray computed tomography (CT) at two time points. The uptake and retention of [(99m)Tc]p5 + 14 in hepatosplenic amyloid was evaluated using region of interest (ROI) and tissue counting measurements. Tc-99m p5 + 14 was produced with a radiochemical yield of 75 % with greater than 90 % purity and biological activity comparable to that of radioiodinated peptide. AA amyloid was visualized by SPECT/CT imaging with specific uptake seen in amyloid-laden organs at levels ∼5 folds higher than in healthy mice. ROI analyses of decay-corrected SPECT/CT images showed <20 % loss of radiolabel from the 1 to 4 h imaging time points. Biodistribution data confirmed the specificity of the probe accumulation by amyloid-laden organs as compared to non-diseased tissues. [(99m)Tc]p5 + 14 is a specific and stable radiotracer for systemic amyloid in mice and may provide a convenient and inexpensive alternative to imaging of peripheral amyloidosis in patients.

  6. A strategy for intensive production of molybdenum-99 isotopes for nuclear medicine using CANDU reactors.

    PubMed

    Morreale, A C; Novog, D R; Luxat, J C

    2012-01-01

    Technetium-99m is an important medical isotope utilized worldwide in nuclear medicine and is produced from the decay of its parent isotope, molybdenum-99. The online fueling capability and compact fuel of the CANDU(®)(1) reactor allows for the potential production of large quantities of (99)Mo. This paper proposes (99)Mo production strategies using modified target fuel bundles loaded into CANDU fuel channels. Using a small group of channels a yield of 89-113% of the weekly world demand for (99)Mo can be obtained. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. Three-dimensional photonic crystals created by single-step multi-directional plasma etching.

    PubMed

    Suzuki, Katsuyoshi; Kitano, Keisuke; Ishizaki, Kenji; Noda, Susumu

    2014-07-14

    We fabricate 3D photonic nanostructures by simultaneous multi-directional plasma etching. This simple and flexible method is enabled by controlling the ion-sheath in reactive-ion-etching equipment. We realize 3D photonic crystals on single-crystalline silicon wafers and show high reflectance (>95%) and low transmittance (<-15dB) at optical communication wavelengths, suggesting the formation of a complete photonic bandgap. Moreover, our method simply demonstrates Si-based 3D photonic crystals that show the photonic bandgap effect in a shorter wavelength range around 0.6 μm, where further fine structures are required.

  8. Single-photon three-qubit quantum logic using spatial light modulators.

    PubMed

    Kagalwala, Kumel H; Di Giuseppe, Giovanni; Abouraddy, Ayman F; Saleh, Bahaa E A

    2017-09-29

    The information-carrying capacity of a single photon can be vastly expanded by exploiting its multiple degrees of freedom: spatial, temporal, and polarization. Although multiple qubits can be encoded per photon, to date only two-qubit single-photon quantum operations have been realized. Here, we report an experimental demonstration of three-qubit single-photon, linear, deterministic quantum gates that exploit photon polarization and the two-dimensional spatial-parity-symmetry of the transverse single-photon field. These gates are implemented using a polarization-sensitive spatial light modulator that provides a robust, non-interferometric, versatile platform for implementing controlled unitary gates. Polarization here represents the control qubit for either separable or entangling unitary operations on the two spatial-parity target qubits. Such gates help generate maximally entangled three-qubit Greenberger-Horne-Zeilinger and W states, which is confirmed by tomographical reconstruction of single-photon density matrices. This strategy provides access to a wide range of three-qubit states and operations for use in few-qubit quantum information processing protocols.Photons are essential for quantum information processing, but to date only two-qubit single-photon operations have been realized. Here the authors demonstrate experimentally a three-qubit single-photon linear deterministic quantum gate by exploiting polarization along with spatial-parity symmetry.

  9. Analysis of deterministic swapping of photonic and atomic states through single-photon Raman interaction

    NASA Astrophysics Data System (ADS)

    Rosenblum, Serge; Borne, Adrien; Dayan, Barak

    2017-03-01

    The long-standing goal of deterministic quantum interactions between single photons and single atoms was recently realized in various experiments. Among these, an appealing demonstration relied on single-photon Raman interaction (SPRINT) in a three-level atom coupled to a single-mode waveguide. In essence, the interference-based process of SPRINT deterministically swaps the qubits encoded in a single photon and a single atom, without the need for additional control pulses. It can also be harnessed to construct passive entangling quantum gates, and can therefore form the basis for scalable quantum networks in which communication between the nodes is carried out only by single-photon pulses. Here we present an analytical and numerical study of SPRINT, characterizing its limitations and defining parameters for its optimal operation. Specifically, we study the effect of losses, imperfect polarization, and the presence of multiple excited states. In all cases we discuss strategies for restoring the operation of SPRINT.

  10. Comparison of 99mTc-MDP SPECT qualitative vs quantitative results in patients with suspected condylar hyperplasia.

    PubMed

    López Buitrago, D F; Ruiz Botero, J; Corral, C M; Carmona, A R; Sabogal, A

    To compare qualitative vs quantitative results of Single Photon Emission Computerised Tomography (SPECT), calculated from percentage of 99m Tc-MDP (methylene diphosphonate) uptake, in condyles of patients with a presumptive clinical diagnosis of condylar hyperplasia. A retrospective, descriptive study was conducted on the 99m Tc-MDP SPECT bone scintigraphy reports from 51 patients, with clinical impression of facial asymmetry related to condylar hyperplasia referred by their specialist in orthodontics or maxillofacial surgery, to a nuclear medicine department in order to take this type of test. Quantitative data from 99m Tc-MDP condylar uptake of each were obtained and compared with qualitative image interpretation reported by a nuclear medicine expert. The concordances between the 51 qualitative and quantitative reports results was established. The total sample included 32 women (63%) and 19 men (37%). The patient age range was 13-45 years (21±8 years). According to qualitative reports, 19 patients were positive for right side condylar hyperplasia, 12 for left side condylar hyperplasia, with 8 bilateral, and 12 negative. The quantitative reports diagnosed 16 positives for right side condylar hyperplasia, 10 for left side condylar hyperplasia, and 25 negatives. Nuclear medicine images are an important diagnostic tool, but the qualitative interpretation of the images is not as reliable as the quantitative calculation. The agreement between the two types of report is low (39.2%, Kappa=0.13; P>.2). The main limitation of quantitative reports is that they do not register bilateral condylar hyperplasia cases. Copyright © 2017 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  11. Ion Exchange Column Tests Supporting Technetium Removal Resin Maturation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nash, C.; McCabe, D.; Hamm, L.

    2013-12-20

    The primary treatment of the tank waste at the DOE Hanford site will be done in the Waste Treatment and Immobilization Plant, currently under construction. The baseline plan for this facility is to treat the waste, splitting it into High Level Waste (HLW) and Low Activity Waste (LAW). Both waste streams are then separately vitrified as glass and sealed in canisters. The LAW glass will be disposed on site. There are currently no plans to treat the waste to remove technetium, so its disposition path is the LAW glass. Due to the soluble properties of pertechnetate and long half-life ofmore » 99Tc, effective management of 99Tc is important. Options are being explored to immobilize the supplemental LAW portion of the tank waste, as well as to examine the volatility of 99Tc during the vitrification process. Removal of 99Tc, followed by off-site disposal has potential to reduce treatment and disposal costs. A conceptual flow sheets for supplemental LAW treatment and disposal that could benefit from technetium removal will specifically examine removing 99Tc from the LAW feed stream to supplemental immobilization. SuperLig® 639 is an elutable ion exchange resin. In the tank waste, 99Tc is predominantly found in the tank supernate as pertechnetate (TcO 4 -). Perrhenate (ReO 4 -) has been shown to be a good non-radioactive surrogate for pertechnetate in laboratory testing for this ion exchange resin. This report contains results of experimental ion exchange distribution coefficient and column resin maturation kinetics testing using the resin SuperLig® 639a to selectively remove perrhenate from simulated LAW. This revision includes results from testing to determine effective resin operating temperature range. Loading tests were performed at 45°C, and the computer modeling was updated to include the temperature effects. Equilibrium contact testing indicated that this batch of SuperLig® 639 resin has good performance, with an average perrhenate distribution coefficient of

  12. Recyclable amplification for single-photon entanglement from photon loss and decoherence

    NASA Astrophysics Data System (ADS)

    Zhou, Lan; Chen, Ling-Quan; Zhong, Wei; Sheng, Yu-Bo

    2018-01-01

    We put forward a highly efficient recyclable single-photon assisted amplification protocol, which can protect single-photon entanglement (SPE) from photon loss and decoherence. Making use of quantum nondemolition detection gates constructed with the help of cross-Kerr nonlinearity, our protocol has some attractive advantages. First, the parties can recover less-entangled SPE to be maximally entangled SPE, and reduce photon loss simultaneously. Second, if the protocol fails, the parties can repeat the protocol to reuse some discarded items, which can increase the success probability. Third, when the protocol is successful, they can similarly repeat the protocol to further increase the fidelity of the SPE. Thereby, our protocol provides a possible way to obtain high entanglement, high fidelity and high success probability simultaneously. In particular, our protocol shows higher success probability in the practical high photon loss channel. Based on the above features, our amplification protocol has potential for future application in long-distance quantum communication.

  13. Waveguide-Coupled Superconducting Nanowire Single-Photon Detectors

    NASA Technical Reports Server (NTRS)

    Beyer, Andrew D.; Briggs, Ryan M.; Marsili, Francesco; Cohen, Justin D.; Meenehan, Sean M.; Painter, Oskar J.; Shaw, Matthew D.

    2015-01-01

    We have demonstrated WSi-based superconducting nanowire single-photon detectors coupled to SiNx waveguides with integrated ring resonators. This photonics platform enables the implementation of robust and efficient photon-counting detectors with fine spectral resolution near 1550 nm.

  14. Technetium-99m HMPAO brain SPECT in autistic children and their families.

    PubMed

    Degirmenci, Berna; Miral, Süha; Kaya, Gamze Capa; Iyilikçi, Leyla; Arslan, Gulhan; Baykara, Ayşen; Evren, Ismail; Durak, Hatice

    2008-04-15

    The purpose of the study was to investigate perfusion patterns in autistic children (AC) and their families. Ten AC (9 boys, 1 girl; mean age: 6.9+/-1.7 years) with autistic disorder defined by DSM-III-R criteria, five age-matched children (3 boys, 2 girls) as a control group, and the immediate family members of eight AC (8 mothers, 8 fathers, 7 siblings; mean ages: 39+/-4 years, 36+/-5 years and 13+/-5 years, respectively) were included in the study. Age- and sex-matched control groups for both the parents and the siblings were also included in the study. Brain perfusion images were obtained 1 h after the intravenous injection of an adjusted dose of Tc-99m HMPAO to children and the adults. Visual and semiquantitative evaluations were performed. Hypoperfusion was seen in the right posterior parietal cortex in three AC, in bilateral parietal cortex in one AC, bilateral frontal cortex in two AC, left parietal and temporal cortex in one AC, and right parietal and temporal cortex in one AC. Asymmetric perfusion was observed in the caudate nucleus in four AC. In semiquantitative analyses, statistically significant hypoperfusion was found in the right inferior and superior frontal, left superior frontal, right parietal, right mesial temporal and right caudate nucleus. In parents of AC, significant hypoperfusion was noted in the right parietal and bilateral inferior frontal cortex. In siblings of AC, perfusion in the right frontal cortex, right nucleus caudate and left parietal cortex was significantly decreased. This preliminary study suggests the existence of regional brain perfusion alterations in frontal, temporal, and parietal cortex and in caudate nucleus in AC and in their first-degree family members.

  15. Heralded noiseless amplification for single-photon entangled state with polarization feature

    NASA Astrophysics Data System (ADS)

    Wang, Dan-Dan; Jin, Yu-Yu; Qin, Sheng-Xian; Zu, Hao; Zhou, Lan; Zhong, Wei; Sheng, Yu-Bo

    2018-03-01

    Heralded noiseless amplification is a promising method to overcome the transmission photon loss in practical noisy quantum channel and can effectively lengthen the quantum communication distance. Single-photon entanglement is an important resource in current quantum communications. Here, we construct two single-photon-assisted heralded noiseless amplification protocols for the single-photon two-mode entangled state and single-photon three-mode W state, respectively, where the single-photon qubit has an arbitrary unknown polarization feature. After the amplification, the fidelity of the single-photon entangled state can be increased, while the polarization feature of the single-photon qubit can be well remained. Both the two protocols only require the linear optical elements, so that they can be realized under current experimental condition. Our protocols may be useful in current and future quantum information processing.

  16. Liver Function in Areas of Hepatic Venous Congestion After Hepatectomy for Liver Cancer: 99mTc-GSA SPECT/CT Fused Imaging Study.

    PubMed

    Yoshida, Morikatsu; Beppu, Toru; Shiraishi, Shinya; Tsuda, Noriko; Sakamoto, Fumi; Kuramoto, Kunitaka; Okabe, Hirohisa; Nitta, Hidetoshi; Imai, Katsunori; Tomiguchi, Seiji; Baba, Hideo; Yamashita, Yasuyuki

    2018-05-01

    Background/Aim: The sacrifice of a major hepatic vein can cause hepatic venous congestion (HVC). We evaluated the effects of HVC on regional liver function using the liver uptake value (LUV), that was calculated from 99m Tc-labeled-galactosyl-human-serum-albumin ( 99m Tc-GSA) single-photon emission computed tomography (SPECT) /contrast-enhanced computed tomography (CE-CT) fused images. Patients and Methods: Sixty-two patients underwent 99m Tc-GSA SPECT/CE-CT prior to hepatectomy for liver cancer and at 7 days after surgery were divided into groups with (n=8) and without HVC (n=54). In the HVC group, CT volume (CTv) and LUV were separately calculated in both congested and non-congested areas. Results: The remnant LUV/CTv of the HVC group was significantly smaller than that of the non-HVC group (p<0.01). The mean functional ratio was 0.47±0.05, and all ratios were ≥0.39. Conclusion: After hepatectomy with sacrifice of major hepatic vein, liver function per unit volume in the congested areas was approximately 40% of that in the non-congested areas. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  17. Quantification of myocardial area at risk in the absence of collateral flow: the validation of angiographic scores by myocardial perfusion single-photon emission computed tomography.

    PubMed

    Rodríguez-Palomares, José F; Alonso, Albert; Martí, Gerard; Aguadé-Bruix, Santiago; González-Alujas, M T; Romero-Farina, Guillermo; Candell-Riera, Jaume; García del Blanco, Bruno; Evangelista, Artur; García-Dorado, David

    2013-02-01

    Our study aimed to compare the area at risk (AAR) determined by single-photon emission computed tomography (SPECT) with the Bypass Angioplasty Revascularization Investigation (BARI) and modified Alberta Provincial Project for Outcome Assessment in Coronary Heart Disease (APPROACH) angiographic scores in the setting of patients undergoing coronary angioplasty for either unstable angina or an STEMI. Radionuclide myocardial perfusion imaging prior to reperfusion has classically been the most widely practised technique for assessing the AAR and has been successfully used to compare the efficacy of various reperfusion strategies in patients with an ST-segment elevation myocardial infarction (STEMI). The BARI and modified APPROACH scores are angiographic methods widely used to provide a rapid estimation of the AAR; however, they have not been directly validated with myocardial perfusion single-photon emission computed tomography (SPECT). Fifty-five patients with no previous myocardial infarction who underwent coronary angioplasty for single-vessel disease (unstable angina: n = 25 or an STEMI: n = 30) with no evidence of collaterals (Rentrop Collateral Score <2) were included in a prospective study. In STEMI patients, the (99m)Tc-tetrofosmin was injected prior to opening of the occluded vessel and, in patients with unstable angina after 10-15 seconds of balloon inflation. Acquisition was performed with a dual-head gammacamera with a low-energy and high-resolution collimator. A total of 60 projections were acquired using a non-circular orbit. No attenuation or scatter correction was used. Maximal contours of hypoperfusion regions corresponding to each coronary artery occlusion were delineated over a polar map of 17 segments and compared with the estimated AAR determined by two experienced interventional cardiologists using both angiographic scores. Mean AAR percentage in SPECT was 35.0 (10.0%-56.0%). A high correlation was found between BARI and APPROACH scores (r = 0.9, P

  18. Radionuclide Sensors and Systems for Monitoring Technetium-99 and Strontium-90 in Groundwater at the Hanford Site

    NASA Astrophysics Data System (ADS)

    Grate, J. W.; O'Hara, M. J.; Egorov, O. B.; Burge, S. R.

    2009-12-01

    We have developed automated sensor and analyzer devices for detection and monitoring of trace radionuclides in water, using preconcentrating columns and radiometric detection. The preconcentrating minicolumn sensor concept combines selective capture and detection in a single functional unit, where the column contains tens to hundreds of milligrams of selectively sorbent material, and the entire column content is monitored with a radiometric detector. Compared to thin film sensors with a few microgram of sorbent, this approach achieves tremendous preconcentration with efficient mass transport via pumping. Furthermore, in an equilibration-based mode of operation, the preconcentration by the sensor is maximized while eliminating the need for consumable reagents to regenerate the column; it can simply be re-equilibrated. We have demonstrated quantification of radionuclides such as technetium-99 to levels below drinking water standards in an equilibration-based process that produces steady state signals, signal proportional to concentration, and easy re-equilibration to new concentration levels. Alternatively, analyzers can be developed with separate separation and detection units that are fluidically linked. We have demonstrated detection of strontium-90 to levels below drinking water standards by this approach. We are developing autonomous systems for at-site monitoring on the Hanford Site in Washington State, using the fluidic sensor and analyzer methods, with the aim of monitoring natural and accelerated attenuation processes, remediation and barrier performance, and contaminant fluxes in the environment. Figure 1. The strontium-90 monitoring method deployed as part of the Burge Environmental Universal Sensor Platform, shown on the shores of the Columbia River on the Hanford site in Washington State.

  19. Fast time-domain measurements on telecom single photons

    NASA Astrophysics Data System (ADS)

    Allgaier, Markus; Vigh, Gesche; Ansari, Vahid; Eigner, Christof; Quiring, Viktor; Ricken, Raimund; Brecht, Benjamin; Silberhorn, Christine

    2017-09-01

    Direct measurements on the temporal envelope of quantum light are a challenging task and not many examples are known because most classical pulse characterisation methods do not work on the single-photon level. Knowledge of both spectrum and timing can, however, give insights on properties that cannot be determined by the spectral intensity alone. While temporal measurements on single photons on timescales of tens of picoseconds are possible with superconducting photon detectors, and picosecond measurements have been performed using streak cameras, there are no commercial single-photon sensitive devices with femtosecond resolution available. While time-domain sampling using sum-frequency generation has already been exploited for such a measurement, inefficient conversion has necessitated long integration times to build the temporal profile. We demonstrate a highly efficient waveguided sum-frequency generation process in Lithium Niobate to measure the temporal envelope of single photons with femtosecond resolution with short enough acquisition time to provide a live-view of the measurement. We demonstrate the measurement technique and combine it with spectral measurements using a dispersive-fibre time-of-flight spectrometer to determine upper and lower bounds for the spectral purity of heralded single photons. The approach complements the joint spectral intensity measurements as a measure on the purity can be given without knowledge of the spectral phase.

  20. Realization of a Cascaded Quantum System: Heralded Absorption of a Single Photon Qubit by a Single-Electron Charged Quantum Dot.

    PubMed

    Delteil, Aymeric; Sun, Zhe; Fält, Stefan; Imamoğlu, Atac

    2017-04-28

    Photonic losses pose a major limitation for the implementation of a quantum state transfer between nodes of a quantum network. A measurement that heralds a successful transfer without revealing any information about the qubit may alleviate this limitation. Here, we demonstrate the heralded absorption of a single photonic qubit, generated by a single neutral quantum dot, by a single-electron charged quantum dot that is located 5 m away. The transfer of quantum information to the spin degree of freedom takes place upon the emission of a photon; for a properly chosen or prepared quantum dot, the detection of this photon yields no information about the qubit. We show that this process can be combined with local operations optically performed on the destination node by measuring classical correlations between the absorbed photon color and the final state of the electron spin. Our work suggests alternative avenues for the realization of quantum information protocols based on cascaded quantum systems.

  1. Single-Photon Ionization Soft-X-Ray Laser Mass Spectrometry of Potential Hydrogen Storage Materials

    NASA Astrophysics Data System (ADS)

    Dong, F.; Bernstein, E. R.; Rocca, J. J.

    A desk-top size capillary discharge 46.9 nm lasear is applied in the gas phase study of nanoclusters. The high photon energy allows for single-photon ionization mass spectrometry with reduced cluster fragmentation. In the present studies, neutral Al m C n and Al m C n H x cluster are investigation for the first time. Single photon ionization through 46.9 nm, 118 nm, 193 nm lasers is used to detect neutral cluster distributions through time of flight mass spectrometry. Al m C n clusters are generated through laser ablation of a mixture of Al and C powders pressed into a disk. An oscillation of the vertical ionization energies (VIEs) of Al m C n clusters is observed in the experiments. The VIEs of Al m C n clusters changes as a function of the numbers of Al and C atoms in the clusters. Al m C n H x clusters are generated through an Al ablation plasma-hydrocarbon reaction, an Al-C ablation plasma reacting with H2 gas, or through cold Al m C n clusters reacting with H2 gas in a fast flow reactor. DFT and ab inito calculations are carried out to explore the structures, IEs, and electronic structures of Al m C n H x clusters. C=C bonds are favored for the lowest energy structures for Al m C n clusters. Be m C n H x are generated through a beryllium ablation plasma-hydrocarbon reaction and detected by single photon ionization of 193 nm laser. Both Al m C n H x and Be m C n H x are considered as potential hydrogen storage materials.

  2. Discordant hepatic uptake between Tc-99m sulfur colloid and Tc-99m DISIDA in hypervitaminosis A

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vincent, L.M.; McCartney, W.H.; Mauro, M.A.

    1984-02-01

    Scintigraphic findings in a patient with biopsy-proven hypervitaminosis A included markedly impaired hepatic uptake of Tc-99m sulfur colloid but essentially normal uptake of Tc-99m DISIDA. This case presents a potential cause for image discordance with these two agents.

  3. High-Performance Single-Photon Sources via Spatial Multiplexing

    DTIC Science & Technology

    2014-01-01

    ingredient for tasks such as quantum cryptography , quantum repeater, quantum teleportation, quantum computing, and truly-random number generation. Recently...SECURITY CLASSIFICATION OF: Single photons sources are desired for many potential quantum information applications. One common method to produce...photons sources are desired for many potential quantum information applications. One common method to produce single photons is based on a “heralding

  4. Single-photon frequency conversion via cascaded quadratic nonlinear processes

    NASA Astrophysics Data System (ADS)

    Xiang, Tong; Sun, Qi-Chao; Li, Yuanhua; Zheng, Yuanlin; Chen, Xianfeng

    2018-06-01

    Frequency conversion of single photons is an important technology for quantum interface and quantum communication networks. Here, single-photon frequency conversion in the telecommunication band is experimentally demonstrated via cascaded quadratic nonlinear processes. Using cascaded quasi-phase-matched sum and difference frequency generation in a periodically poled lithium niobate waveguide, the signal photon of a photon pair from spontaneous down-conversion is precisely shifted to identically match its counterpart, i.e., the idler photon, in frequency to manifest a clear nonclassical dip in the Hong-Ou-Mandel interference. Moreover, quantum entanglement between the photon pair is maintained after the frequency conversion, as is proved in time-energy entanglement measurement. The scheme is used to switch single photons between dense wavelength-division multiplexing channels, which holds great promise in applications in realistic quantum networks.

  5. Entanglement and quantum superposition induced by a single photon

    NASA Astrophysics Data System (ADS)

    Lü, Xin-You; Zhu, Gui-Lei; Zheng, Li-Li; Wu, Ying

    2018-03-01

    We predict the occurrence of single-photon-induced entanglement and quantum superposition in a hybrid quantum model, introducing an optomechanical coupling into the Rabi model. Originally, it comes from the photon-dependent quantum property of the ground state featured by the proposed hybrid model. It is associated with a single-photon-induced quantum phase transition, and is immune to the A2 term of the spin-field interaction. Moreover, the obtained quantum superposition state is actually a squeezed cat state, which can significantly enhance precision in quantum metrology. This work offers an approach to manipulate entanglement and quantum superposition with a single photon, which might have potential applications in the engineering of new single-photon quantum devices, and also fundamentally broaden the regime of cavity QED.

  6. Efficient fiber-coupled single-photon source based on quantum dots in a photonic-crystal waveguide

    PubMed Central

    DAVEAU, RAPHAËL S.; BALRAM, KRISHNA C.; PREGNOLATO, TOMMASO; LIU, JIN; LEE, EUN H.; SONG, JIN D.; VERMA, VARUN; MIRIN, RICHARD; NAM, SAE WOO; MIDOLO, LEONARDO; STOBBE, SØREN; SRINIVASAN, KARTIK; LODAHL, PETER

    2017-01-01

    Many photonic quantum information processing applications would benefit from a high brightness, fiber-coupled source of triggered single photons. Here, we present a fiber-coupled photonic-crystal waveguide single-photon source relying on evanescent coupling of the light field from a tapered out-coupler to an optical fiber. A two-step approach is taken where the performance of the tapered out-coupler is recorded first on an independent device containing an on-chip reflector. Reflection measurements establish that the chip-to-fiber coupling efficiency exceeds 80 %. The detailed characterization of a high-efficiency photonic-crystal waveguide extended with a tapered out-coupling section is then performed. The corresponding overall single-photon source efficiency is 10.9 % ± 2.3 %, which quantifies the success probability to prepare an exciton in the quantum dot, couple it out as a photon in the waveguide, and subsequently transfer it to the fiber. The applied out-coupling method is robust, stable over time, and broadband over several tens of nanometers, which makes it a highly promising pathway to increase the efficiency and reliability of planar chip-based single-photon sources. PMID:28584859

  7. Intravascular lymphomatosis presenting as acute hemispheric dysfunction.

    PubMed

    Hwang, Woo Sub; Jung, Chul Won; Ko, Young Hye; Seo, Sang Won; Na, Duk L

    2012-11-01

    Intravascular lymphomatosis (IVL) is known to affect both hemispheres of the brain and manifests clinically as seizures or dementia. To our knowledge, there have been no cases in which acute hemispheric dysfunction is manifested in IVL. We present a 54-year-old man who showed steroid responsive acute hemispheric dysfunction. A technetium 99m-ethyl cysteinate dimer single-photon emission computed tomographic scan of the brain revealed hypoperfusion in the right hemisphere. The bone marrow biopsy specimen confirmed malignant lymphoid cells in vessels, which suggested IVL. Our case signifies the diversity of clinical manifestations in IVL. Copyright © 2012. Published by Elsevier Inc.

  8. Deterministic and storable single-photon source based on a quantum memory.

    PubMed

    Chen, Shuai; Chen, Yu-Ao; Strassel, Thorsten; Yuan, Zhen-Sheng; Zhao, Bo; Schmiedmayer, Jörg; Pan, Jian-Wei

    2006-10-27

    A single-photon source is realized with a cold atomic ensemble (87Rb atoms). A single excitation, written in an atomic quantum memory by Raman scattering of a laser pulse, is retrieved deterministically as a single photon at a predetermined time. It is shown that the production rate of single photons can be enhanced considerably by a feedback circuit while the single-photon quality is conserved. Such a single-photon source is well suited for future large-scale realization of quantum communication and linear optical quantum computation.

  9. Scatter and cross-talk corrections in simultaneous Tc-99m/I-123 brain SPECT using constrained factor analysis and artificial neural networks

    NASA Astrophysics Data System (ADS)

    Fakhri, G. El; Maksud, P.; Kijewski, M. F.; Haberi, M. O.; Todd-Pokropek, A.; Aurengo, A.; Moore, S. C.

    2000-08-01

    Simultaneous imaging of Tc-99m and I-123 would have a high clinical potential in the assessment of brain perfusion (Tc-99m) and neurotransmission (I-123) but is hindered by cross-talk between the two radionuclides. Monte Carlo simulations of 15 different dual-isotope studies were performed using a digital brain phantom. Several physiologic Tc-99m and I-123 uptake patterns were modeled in the brain structures. Two methods were considered to correct for cross-talk from both scattered and unscattered photons: constrained spectral factor analysis (SFA) and artificial neural networks (ANN). The accuracy and precision of reconstructed pixel values within several brain structures were compared to those obtained with an energy windowing method (WSA). In I-123 images, mean bias was close to 10% in all structures for SFA and ANN and between 14% (in the caudate nucleus) and 25% (in the cerebellum) for WSA. Tc-99m activity was overestimated by 35% in the cortex and 53% in the caudate nucleus with WSA, but by less than 9% in all structures with SFA and ANN. SFA and ANN performed well even in the presence of high-energy I-123 photons. The accuracy was greatly improved by incorporating the contamination into the SFA model or in the learning phase for ANN. SFA and ANN are promising approaches to correct for cross-talk in simultaneous Tc-99m/I-123 SPECT.

  10. Single photon laser altimeter data processing, analysis and experimental validation

    NASA Astrophysics Data System (ADS)

    Vacek, Michael; Peca, Marek; Michalek, Vojtech; Prochazka, Ivan

    2015-10-01

    Spaceborne laser altimeters are common instruments on-board the rendezvous spacecraft. This manuscript deals with the altimeters using a single photon approach, which belongs to the family of time-of-flight range measurements. Moreover, the single photon receiver part of the altimeter may be utilized as an Earth-to-spacecraft link enabling one-way ranging, time transfer and data transfer. The single photon altimeters evaluate actual altitude through the repetitive detections of single photons of the reflected laser pulses. We propose the single photon altimeter signal processing and data mining algorithm based on the Poisson statistic filter (histogram method) and the modified Kalman filter, providing all common altimetry products (altitude, slope, background photon flux and albedo). The Kalman filter is extended for the background noise filtering, the varying slope adaptation and the non-causal extension for an abrupt slope change. Moreover, the algorithm partially removes the major drawback of a single photon altitude reading, namely that the photon detection measurement statistics must be gathered. The developed algorithm deduces the actual altitude on the basis of a single photon detection; thus, being optimal in the sense that each detected signal photon carrying altitude information is tracked and no altitude information is lost. The algorithm was tested on the simulated datasets and partially cross-probed with the experimental data collected using the developed single photon altimeter breadboard based on the microchip laser with the pulse energy on the order of microjoule and the repetition rate of several kilohertz. We demonstrated that such an altimeter configuration may be utilized for landing or hovering a small body (asteroid, comet).

  11. 99mTc-EDDA/HYNIC-TOC and (18)F-FDG in thyroid cancer patients with negative (131)I whole-body scans.

    PubMed

    Gabriel, Michael; Froehlich, Franz; Decristoforo, Clemens; Ensinger, Christian; Donnemiller, Eveline; von Guggenberg, Elisabeth; Heute, Dirk; Moncayo, Roy

    2004-03-01

    Several studies have reported on the expression of somatostatin receptors in patients with differentiated thyroid cancer (DTC). The aim of this study was to evaluate the imaging abilities of a recently developed technetium-99m labelled somatostatin analogue, (99m)Tc-EDDA/HYNIC-TOC ((99m)Tc-TOC), in terms of precise localisation of disease. The study population comprised 54 patients (24 men, 30 women; age range 22-90 years) with histologically confirmed DTC who presented with recurrent or persistent disease as indicated by elevated Tg levels after initial treatment. All patients were negative on the iodine-131 post-therapy whole-body scans. Fluorine-18 fluorodeoxyglucose positron emission tomography ((18)F-FDG PET) was performed in a subgroup of 36 patients. The study population consisted of two groups: Group A ( n=22) comprised patients with disease recurrence as shown by elevated Tg levels but without detectable pathology. In group B ( n=32), pre-existing lesions were known. Among the 54 cases, SSTR scintigraphy was true positive in 33 (61.1%), true negative in 4 (7.4%) and false negative in 17 (31.5%) cases, which resulted in a sensitivity of 66%. A total of 138 tumour foci were localised in 33 patients. The fraction of true positive (99m)Tc-TOC findings was positively correlated ( P<0.01) with elevated Tg levels (higher than 30 ng/ml). Despite two false positive findings, analysis on a lesion basis demonstrated better diagnostic efficacy with (18)F-FDG PET ( P<0.001); however, it also revealed substantial agreement between the imaging techniques [Cohen's kappa of 0.62 (0.47-0.78)]. In conclusion, scintigraphy with (99m)Tc-TOC might be a promising tool for treatment planning; it is easy to perform and showed sufficient accuracy for localisation diagnostics in thyroid cancer patients with recurrent or metastatic disease.

  12. Quantum Probability Cancellation Due to a Single-Photon State

    NASA Technical Reports Server (NTRS)

    Ou, Z. Y.

    1996-01-01

    When an N-photon state enters a lossless symmetric beamsplitter from one input port, the photon distribution for the two output ports has the form of Bernouli Binormial, with highest probability at equal partition (N/2 at one outport and N/2 at the other). However, injection of a single photon state at the other input port can dramatically change the photon distribution at the outputs, resulting in zero probability at equal partition. Such a strong deviation from classical particle theory stems from quantum probability amplitude cancellation. The effect persists even if the N-photon state is replaced by an arbitrary state of light. A special case is the coherent state which corresponds to homodyne detection of a single photon state and can lead to the measurement of the wave function of a single photon state.

  13. Radioaerosol lung imaging in chronic obstructive pulmonary disease. Comparison with pulmonary function tests and roentgenography. [/sup 113m/In, /sup 99m/Tc, /sup 133/Xe tracer techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ramanna, L.; Tashkin, D.P.; Taplin, G.V.

    1975-11-01

    Seventy subjects with either no, mild, or definite evidence of pulmonary abnormality on screening studies volunteered to have detailed pulmonary function tests (PFTs), respiratory questionnaires, physical examinations, and /sup 113m/indium aerosol-inhalation lung imaging performed. Also, 22 and 52 of these subjects underwent /sup 133/xenon ventilation and lung perfusion imaging with /sup 99m/technetium-labelled macroaggregated albumin, and 56 had chest x-ray examinations performed. Results of the radionuclide lung-imaging procedures were compared with those of conventional PFTs and other clinical diagnostic procedures used to identify chronic obstructive pulmonary disease (COPD). Abnormal radioaerosol patterns were found in 32 of 33 subjects with abnormal findingsmore » on PFTs, whereas results of PFTs were abnormal in only 32 of 46 subjects with abnormal aerosol deposition. Aerosol lung images were abnormal more frequently than respiratory questionnaire responses, findings on physical examination, chest x-ray films, and perfusion lung images and with approximately the same frequency as /sup 133/xenon ventilation scintiscans. These results suggest that radioaerosol lung imaging may be a more sensitive indicator of early COPD than other diagnostic procedures, including maximal midexpiratory flow rates, single-breath nitrogen washout, and closing volume. Further studies are required to determine the physiologic and pathologic significance of isolated aerosol lung-imaging abnormalities.« less

  14. Analysis of accumulation of 99mTc-octreotide and 99mTc-EDDA/HYNIC-Tyr3-octreotide in the rat kidneys.

    PubMed

    Kopecky, Martin; Semecky, Vladimir; Trejtnar, Frantisek; Laznicek, Milan; Laznickova, Alice; Nachtigal, Petr; Decristoforo, Clemens; Mather, Stephen J; Mäcke, Helmut R

    2004-02-01

    The aim of this study was to compare renal handling and distribution of (99m)Tc-octreotide and (99m)Tc-EDDA/HYNIC-Tyr(3)-octreotide (HYNIC-TOC) in rats. In kidney perfusion experiments, the renal clearance value of (99m)Tc-octreotide was three times lower than that of (99m)Tc-EDDA/HYNIC-TOC. The predominant renal excretion of (99m)Tc-EDDA/HYNIC-TOC was associated with a high and long-term renal accumulation up to 48 hrs. Microautoradiographic results indicated that (99m)Tc-EDDA/HYNIC-TOC was retained mainly in the renal medulla within the cells of the collecting ducts and in the surrounding tissue. Lower positivity was found in the proximal and distal tubular cells. We conclude that the mechanism of renal accumulation of somatostatin analogues renal accumulation is complex and that proximal tubular reabsorption is probably not the main mechanism for uptake of (99m)Tc-EDDA/HYNIC-TOC in the kidneys. The presence of the somatostatin receptors, differences in the tonicity level within kidneys and other possible mechanisms could participate in their renal accumulation.

  15. Mode Engineering of Single Photons from Cavity Spontaneous Parametric Down-Conversion Source and Quantum Dots

    NASA Astrophysics Data System (ADS)

    Paudel, Uttam

    Over the past decade, much effort has been made in identifying and characterizing systems that can form a building block of quantum networks, among which semiconductor quantum dots (QD) and spontaneous parametric down-conversion (SPDC) source are two of the most promising candidates. The work presented in this thesis will be centered on investigating and engineering the mentioned systems for generating customizable single photons. A type-II SPDC source can generate a highly flexible pair of entangled photons that can be used to interface disparate quantum systems. In this thesis, we have successfully implemented a cavity-SPDC source that emits polarization correlated photons at 942 nm with a lifetime of 950-1050ps that mode matches closely with InAs/GaAs QD photons. The source emits 80 photon pairs per second per mW pump power within the 150MHz bandwidth. Though the detection of idler photons, the source is capable of emitting heralded photons with g2?0.5 for up to 40 mW pump power. For a low pump power of 5 mW, the heralded g2 is 0.06, indicating that the system is an excellent heralded single photon source. By directly exciting a single QD with cavity-SPDC photons, we have demonstrated a heralded-absorption of SPDC photons by QD, resulting in the coupling of the two systems. Due to the large pump bandwidth, the emitted source is highly multimode in nature, requiring us to post-filter the downconverted field, resulting in a lower photon pair emission rate. We propose placing an intra-cavity etalon to suppress the multi-mode emissions and increase the photon count rate. Understanding and experimentally implementing two-photon interference (HOM) measurements will be crucial for building a scalable quantum network. A detailed theoretical description of HOM measurements is given and is experimentally demonstrated using photons emitted by QD. Through HOM measurements we demonstrated that the QD sample in the study is capable of emitting indistinguishable photons, with

  16. Single-photon routing with whispering-gallery resonators

    NASA Astrophysics Data System (ADS)

    Huang, Jin-Song; Zhang, Jia-Hao; Wei, L. F.

    2018-04-01

    Quantum routing of single photons in a system with two waveguides coupled to two whispering-gallery resonators (WGRs) are investigated theoretically. Using a real-space full quantum theory, photonic scattering amplitudes along four ports of the waveguide network are analytically obtained. It is shown that, by adjusting the geometric and physical parameters of the two-WGR configuration, the quantum routing properties of single photons along the present waveguide network can be controlled effectively. The routing capability from input waveguide to another one can significantly exceed 0.5 near the resonance point of scattering spectra, which can be achieved with only one resonator. By properly designing the distance between two WGRs and the waveguide-WGR coupling strengths, the transfer rate between the waveguides can also reach certain sufficiently high values even in the non-resonance regime. Moreover, Fano-like resonances in the scattering spectra are designable. The proposed system may provide a potential application in controlling single-photon quantum routing.

  17. Impact of Indocyanine Green for Sentinel Lymph Node Mapping in Early Stage Endometrial and Cervical Cancer: Comparison with Conventional Radiotracer (99m)Tc and/or Blue Dye.

    PubMed

    Buda, Alessandro; Crivellaro, Cinzia; Elisei, Federica; Di Martino, Giampaolo; Guerra, Luca; De Ponti, Elena; Cuzzocrea, Marco; Giuliani, Daniela; Sina, Federica; Magni, Sonia; Landoni, Claudio; Milani, Rodolfo

    2016-07-01

    To compare the detection rate (DR) and bilateral optimal mapping (OM) of sentinel lymph nodes (SLNs) in women with endometrial and cervical cancer using indocyanine green (ICG) versus the standard technetium-99m radiocolloid ((99m)Tc) radiotracer plus methylene or isosulfan blue, or blue dye alone. From October 2010 to May 2015, 163 women with stage I endometrial or cervical cancer (118 endometrial and 45 cervical cancer) underwent SLN mapping with (99m)Tc with blue dye, blue dye alone, or ICG. DR and bilateral OM of ICG were compared respectively with the results obtained using the standard (99m)Tc radiotracer with blue dye, or blue dye alone. SLN mapping with (99m)Tc radiotracer with blue dye was performed on 77 of 163 women, 38 with blue dye only and 48 with ICG. The overall DR of SLN mapping was 97, 89, and 100 % for (99m)Tc with blue dye, blue dye alone, and ICG, respectively. The bilateral OM rate for ICG was 85 %-significantly higher than the 58 % obtained with (99m)Tc with blue dye (p = 0.003) and the 54 % for blue dye (p = 0.001). Thirty-one women (19 %) had positive SLNs. Sensitivity and negative predictive value of SLN were 100 % for all techniques. SLNs mapping using ICG demonstrated higher DR compared to other modalities. In addition, ICG was significantly superior to (99m)Tc with blue dye in terms of bilateral OM in women with early stage endometrial and cervical cancer. The higher number of bilateral OM may consequently reduce the overall number of complete lymphadenectomies, reducing the duration and additional costs of surgical treatment.

  18. Bone accumulation of the Tc-99m complex of carbamyl phosphate and its analogs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hosain, P.; Spencer, R.P.; Ahlquist, K.J.

    1978-05-01

    Carbamyl phosphate, an organic moecule containing a single phosphate group, has been used in the therapy of sickle-cell disease. Carbamyl phosphate bound Tc-99m and achieved bone uptake in mice, rabbits, and a human volunteer. By examination of the structural formula, a working hypothesis was developed that predicted that the Tc-99m complexes of the analogous compounds acetyl phosphate, propionyl phosphate, and butyryl phosphate, each carrying single phosphate and carbonyl groups, would also show bone specificity. This was confirmed experimentally. Phosphonoacetic acid is a structural analog of these compounds. The structural analysis also predicted that aminomethylphosphonic acid and phosphoenolpyruvate would not havemore » as avid bone affinity, and this was also confirmed. These compounds represent a new class of bone-seeking agents that have the common properties of a lone phosphate and a carbonyl function. Such agents may permit the synthesis of additional analogs in an effort to obtain optimal affinity in the Tc-99m complexes.« less

  19. Time-Bin-Encoded Boson Sampling with a Single-Photon Device.

    PubMed

    He, Yu; Ding, X; Su, Z-E; Huang, H-L; Qin, J; Wang, C; Unsleber, S; Chen, C; Wang, H; He, Y-M; Wang, X-L; Zhang, W-J; Chen, S-J; Schneider, C; Kamp, M; You, L-X; Wang, Z; Höfling, S; Lu, Chao-Yang; Pan, Jian-Wei

    2017-05-12

    Boson sampling is a problem strongly believed to be intractable for classical computers, but can be naturally solved on a specialized photonic quantum simulator. Here, we implement the first time-bin-encoded boson sampling using a highly indistinguishable (∼94%) single-photon source based on a single quantum-dot-micropillar device. The protocol requires only one single-photon source, two detectors, and a loop-based interferometer for an arbitrary number of photons. The single-photon pulse train is time-bin encoded and deterministically injected into an electrically programmable multimode network. The observed three- and four-photon boson sampling rates are 18.8 and 0.2 Hz, respectively, which are more than 100 times faster than previous experiments based on parametric down-conversion.

  20. Single photon laser altimeter simulator and statistical signal processing

    NASA Astrophysics Data System (ADS)

    Vacek, Michael; Prochazka, Ivan

    2013-05-01

    Spaceborne altimeters are common instruments onboard the deep space rendezvous spacecrafts. They provide range and topographic measurements critical in spacecraft navigation. Simultaneously, the receiver part may be utilized for Earth-to-satellite link, one way time transfer, and precise optical radiometry. The main advantage of single photon counting approach is the ability of processing signals with very low signal-to-noise ratio eliminating the need of large telescopes and high power laser source. Extremely small, rugged and compact microchip lasers can be employed. The major limiting factor, on the other hand, is the acquisition time needed to gather sufficient volume of data in repetitive measurements in order to process and evaluate the data appropriately. Statistical signal processing is adopted to detect signals with average strength much lower than one photon per measurement. A comprehensive simulator design and range signal processing algorithm are presented to identify a mission specific altimeter configuration. Typical mission scenarios (celestial body surface landing and topographical mapping) are simulated and evaluated. The high interest and promising single photon altimeter applications are low-orbit (˜10 km) and low-radial velocity (several m/s) topographical mapping (asteroids, Phobos and Deimos) and landing altimetry (˜10 km) where range evaluation repetition rates of ˜100 Hz and 0.1 m precision may be achieved. Moon landing and asteroid Itokawa topographical mapping scenario simulations are discussed in more detail.

  1. Semi-quantum Dialogue Based on Single Photons

    NASA Astrophysics Data System (ADS)

    Ye, Tian-Yu; Ye, Chong-Qiang

    2018-02-01

    In this paper, we propose two semi-quantum dialogue (SQD) protocols by using single photons as the quantum carriers, where one requires the classical party to possess the measurement capability and the other does not have this requirement. The security toward active attacks from an outside Eve in the first SQD protocol is guaranteed by the complete robustness of present semi-quantum key distribution (SQKD) protocols, the classical one-time pad encryption, the classical party's randomization operation and the decoy photon technology. The information leakage problem of the first SQD protocol is overcome by the classical party' classical basis measurements on the single photons carrying messages which makes him share their initial states with the quantum party. The security toward active attacks from Eve in the second SQD protocol is guaranteed by the classical party's randomization operation, the complete robustness of present SQKD protocol and the classical one-time pad encryption. The information leakage problem of the second SQD protocol is overcome by the quantum party' classical basis measurements on each two adjacent single photons carrying messages which makes her share their initial states with the classical party. Compared with the traditional information leakage resistant QD protocols, the advantage of the proposed SQD protocols lies in that they only require one party to have quantum capabilities. Compared with the existing SQD protocol, the advantage of the proposed SQD protocols lies in that they only employ single photons rather than two-photon entangled states as the quantum carriers. The proposed SQD protocols can be implemented with present quantum technologies.

  2. Comparison of (99m)Tc-labeled PR81 and its F(ab')₂ fragments as radioimmunoscintigraphy agents for breast cancer imaging.

    PubMed

    Salouti, Mojtaba; Babaei, Mohammad Hossein; Rajabi, Hossein; Foroutan, Haleh; Rasaee, Mohammad Javad; Rajabi, Ahmad Bitarafan; Mohammadnejad, Javad; Shafiee, Mohammad; Mazidi, Mohammad; Daha, Fariba Johari

    2011-02-01

    We digested anti-MUC1 monoclonal antibody PR81 to produce F(ab')₂ fragments. A comparison was performed between the two radiolabeled PR81 and F(ab')₂ fragments for breast tumor imaging in a mouse model. The optimum conditions for pepsin digestion of PR81 were investigated in terms of enzymes: antibody ratio, digestion time duration and preserved immunoreactivity of the produced fragments. The F(ab')₂ fragments were labeled with Technetium-99m using HYNIC as a chelator and tricine as a co-ligand. The immunoreactivity of the complexes was assessed by radioimmunoassay using MCF7 cells. Biodistribution and imaging studies were performed in female BALB/c mice with breast tumor xenograft at 4, 8 and 24 h post-administration. The PR81 was labeled with technetium-99m in the same way for comparison. The optimum time duration for PR81 digestion was found to be 28 h at an enzyme:antibody weight ratio of 1:20 that resulted in 95.2 ± 4.7% purity. The labeling of intact PR81 and its F(ab')₂ fragments were 87.6 ± 4.2 and 76.1 ± 3.3% after 1 h, respectively (p value <0.05). The percentage of immunoreactivity of F(ab')₂ fragments and intact PR81 were 75.4 ± 2.1% and 85.7 ± 2.9%, respectively (p value <0.05). The biodistribution and imaging studies demonstrated localization of the fragments at 4 h post-administration with high sensitivity and specificity. The results showed that F(ab')₂ fragment of PR81 is more suitable than intact PR81 for safer and more rapid detection of human breast cancer.

  3. Concordance between (99m)Tc-ECD SPECT and 18F-FDG PET interpretations in patients with cognitive disorders diagnosed according to NIA-AA criteria.

    PubMed

    Ito, Kimiteru; Shimano, Yasumasa; Imabayashi, Etsuko; Nakata, Yasuhiro; Omachi, Yoshie; Sato, Noriko; Arima, Kunimasa; Matsuda, Hiroshi

    2014-10-01

    The purpose of this study was to clarify the concordance of diagnostic abilities and interobserver agreement between 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) and brain perfusion single photon-emission computed tomography (SPECT) in patients with Alzheimer's disease (AD) who were diagnosed according to the research criteria of the National Institute of Aging-Alzheimer's Association Workshop. Fifty-five patients with "AD and mild cognitive impairment (MCI)" (n = 40) and "non-AD" (n = 15) were evaluated with 18F-FDG PET and (99m)Tc-ethyl cysteinate dimer (ECD) SPECT during an 8-week period. Three radiologists independently graded the regional uptake in the frontal, temporal, parietal, and occipital lobes as well as the precuneus/posterior cingulate cortex in both images. Kappa values were used to determine the interobserver reliability regarding regional uptake. The regions with better interobserver reliability between 18F-FDG PET and (99m)Tc-ECD SPECT were the frontal, parietal, and temporal lobes. The (99m)Tc-ECD SPECT agreement in the occipital lobes was not significant. The frontal, temporal, and parietal lobes showed good correlations between 18F-FDG PET and (99m)Tc-ECD SPECT in the degree of uptake, but the occipital lobe and precuneus/posterior cingulate cortex did not show good correlations. The diagnostic accuracy rates of "AD and MCI" ranged from 60% to 70% in both of the techniques. The degree of uptake on 18F-FDG PET and (99m)Tc-ECD SPECT showed significant correlations in the frontal, temporal, and parietal lobes. The diagnostic abilities of 18F-FDG PET and (99m)Tc-ECD SPECT for "AD and MCI," when diagnosed according to the National Institute of Aging-Alzheimer's Association Workshop criteria, were nearly identical. Copyright © 2014 John Wiley & Sons, Ltd.

  4. On-chip low loss heralded source of pure single photons.

    PubMed

    Spring, Justin B; Salter, Patrick S; Metcalf, Benjamin J; Humphreys, Peter C; Moore, Merritt; Thomas-Peter, Nicholas; Barbieri, Marco; Jin, Xian-Min; Langford, Nathan K; Kolthammer, W Steven; Booth, Martin J; Walmsley, Ian A

    2013-06-03

    A key obstacle to the experimental realization of many photonic quantum-enhanced technologies is the lack of low-loss sources of single photons in pure quantum states. We demonstrate a promising solution: generation of heralded single photons in a silica photonic chip by spontaneous four-wave mixing. A heralding efficiency of 40%, corresponding to a preparation efficiency of 80% accounting for detector performance, is achieved due to efficient coupling of the low-loss source to optical fibers. A single photon purity of 0.86 is measured from the source number statistics without narrow spectral filtering, and confirmed by direct measurement of the joint spectral intensity. We calculate that similar high-heralded-purity output can be obtained from visible to telecom spectral regions using this approach. On-chip silica sources can have immediate application in a wide range of single-photon quantum optics applications which employ silica photonics.

  5. Clinical usefulness of 99mTc-EDDA/HYNIC-TOC scintigraphy in oncological diagnostics: a pilot study.

    PubMed

    Plachcinska, Anna; Mikolajczak, Renata; Maecke, Helmut; Mlodkowska, Ewa; Kunert-Radek, Jolanta; Michalski, Andrzej; Rzeszutek, Katarzyna; Kozak, Jozek; Kusmierek, Jacek

    2004-04-01

    The clinical usefulness of a new 99mTc-labeled somatostatin analogue has been studied from the standpoint of oncological diagnostics. The group of patients studied included 40 individuals with diagnosed malignant neoplasms (32 primary and 8 metastatic). Among the primary tumors were 7 pituitary adenomas (5 hormonally active and 2 inactive), 1 liposarcoma, 2 carcinoids, 1 breast carcinoma, and 21 cases of lung cancer (2 small cell and 19 non-small cell) were represented. The metastatic tumors consisted of: 3 malignant melanomas, 1 pheochromocytoma, 1 prostatic cancer, 1 leiomyosarcoma, 1 pancreatic carcinoma ectopically secreting ACTH, and 1 carcinoid of the thymus. The radiopharmaceutical, 99mTc-EDDA/HYNIC-octreotide, was i.v. administered at the activity of 740-925 MBq. The imaging was comprized of a whole-body scan and single photon emission computed tomography. Positive scintigrams were obtained in 4 of 5 hormonally active pituitary adenomas, in 1 of 2 cases of carcinoid, in liposarcoma, breast cancer, and all cases of small cell (SCLC) and non-small cell lung cancer (NSCLC). The neoplastic metastases were visualized in 2 of 3 cases of melanoma and in patients with pheochromocytoma, pancreatic carcinoma secreting ACTH, and thymic carcinoid. Scintigrams were negative in both hormonally inactive pituitary adenomas, in one case of metastatic malignant melanoma, leiomyosarcoma, and in cases of metastasis from the prostatic carcinomas. The results of this pilot study indicated that 99mTc-EDDA/HYNIC-TOC is a potentially useful radiopharmaceutical for the imaging of a wide range of primary and metastatic tumors. More detailed indications for the clinical usefulness of the new tracer for the imaging of selected tumor types require studies on much larger groups of patients. Special attention should be paid to the successful imaging of all cases of NSCLC.

  6. Fiber-Coupled Cavity-QED Source of Identical Single Photons

    NASA Astrophysics Data System (ADS)

    Snijders, H.; Frey, J. A.; Norman, J.; Post, V. P.; Gossard, A. C.; Bowers, J. E.; van Exter, M. P.; Löffler, W.; Bouwmeester, D.

    2018-03-01

    We present a fully fiber-coupled source of high-fidelity single photons. An (In,Ga)As semiconductor quantum dot is embedded in an optical Fabry-Perot microcavity with a robust design and rigidly attached single-mode fibers, which enables through-fiber cross-polarized resonant laser excitation and photon extraction. Even without spectral filtering, we observe that the incident coherent light pulses are transformed into a stream of single photons with high purity (97%) and indistinguishability (90%), which is measured at an in-fiber brightness of 5% with an excellent cavity-mode-to-fiber coupling efficiency of 85%. Our results pave the way for fully fiber-integrated photonic quantum networks. Furthermore, our method is equally applicable to fiber-coupled solid-state cavity-QED-based photonic quantum gates.

  7. Design of single-polarization wavelength splitter based on photonic crystal fiber.

    PubMed

    Zhang, Shanshan; Zhang, Weigang; Geng, Pengcheng; Li, Xiaolan; Ruan, Juan

    2011-12-20

    A new single-polarization wavelength splitter based on the photonic crystal fiber (PCF) has been proposed. The full-vector finite-element method (FEM) is applied to analyze the single-polarization single-mode guiding properties. Splitting of two different wavelengths is realized by adjusting the structural parameters. The semi-vector three-dimensional beam propagation method is employed to confirm the wavelength splitting characteristics of the PCF. Numerical simulations show that the wavelengths of 1.3 μm and 1.55 μm are split for a fiber length of 10.7 mm with single-polarization guiding in each core. The crosstalk between the two cores is low over appreciable optical bandwidths.

  8. Initial direct comparison of 99mTc-TOC and 99mTc-TATE in identifying sites of disease in patients with proven GEP NETs.

    PubMed

    Cwikla, Jaroslaw B; Mikolajczak, Renata; Pawlak, Dariusz; Buscombe, John R; Nasierowska-Guttmejer, Anna; Bator, Andrzej; Maecke, Helmut R; Walecki, Jerzy

    2008-07-01

    The imaging of neuroendocrine tumors has become one of the most significant areas in nuclear oncology. In an attempt to provide high-quality imaging and possible sensitivity at a reduced cost, time, and radiation dose, several (99m)Tc agents have been proposed. The aim of this initial study was to compare the tumor uptake and biodistribution of 2 new 6-hydrazinopyridine-3-carboxylic acid (HYNIC)-derivatized Tyr(3)-octreotide analogs, (99m)Tc-[HYNIC,Tyr(3)]octreotide ((99m)Tc-TOC) and (99m)Tc-[HYNIC,Tyr(3),Thr(8)]octreotide ((99m)Tc-TATE), in patients with somatostatin receptor-expressing tumors. Each of 12 patients with proven gastrointestinal pancreatic neuroendocrine tumors received a mean activity of 520 MBq of (99m)Tc-TOC and (99m)Tc-TATE. Scintigraphy with both tracers was performed 3-4 h after their injection using standard whole-body and SPECT imaging. The images were reviewed subjectively by 2 readers, who reported tumor uptake lesion by lesion. Both radiotracers demonstrated concordance between the results in 7 patients (58%). In total, 110 sites of disease were identified with (99m)Tc-TOC, compared with 115 with (99m)Tc-TATE. There was 1 case in which (99m)Tc-TOC identified sites of disease not seen on (99m)Tc-TATE imaging but 4 cases in which some sites of disease were seen with (99m)Tc-TATE and not (99m)Tc-TOC. In this initial study, both tracers seem to show similar sites of tumor, with (99m)Tc-TATE having a slight edge in the total number of lesions seen, especially in lymph node metastases.

  9. Technetium-99 and strontium-90: Abundance determination at ultratrace sensitivity by AMS as signatures of undeclared nuclear reprocessing activity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McAninch, J.E.; Proctor, I.D.

    1995-03-01

    The purpose of this White Paper is to examine the use of the ultratrace technique Accelerator Mass Spectrometry (AMS) to lower detection limits for {sup 99}Tc and {sup 90}Sr, and to examine the utility of these isotopes as signatures of a convert reprocessing facility. The International Atomic Energy Agency (IAEA) has committed to improving the effectiveness of the IAEA Safeguards System. This is in some degree a result of the discovery in 1991 of an undeclared Iraqi EMIS program. Recommendations from the March 1993 Consultants Group Meeting have resulted in several studies and follow on field trials to identify environmentalmore » signatures from covert nuclear fuel reprocessing activity. In particular, the April, 1993 reports of the Standing Advisory Group on Safeguards Implementation (SAGSI) identified the long-lived radioisotopes Technetium-99 and strontium-90 as two reliable signatures of fuel reprocessing activity. This report also suggested pathways in the chemical processing of irradiated fuel where these elements would be volatilized and potentially released in amounts detectable with ultratrace sensitivity techniques. Based on measured {sup 99}Tc background levels compiled from a variety of sources, it is estimated that AMS can provide 10% measurements of environmental levels of {sup 99}Tc in a few minutes using modestly sized samples: a few grams for soils, plants, or animal tissues; one to several liters for rain or seawater samples; and tens to hundreds of cubic meters for air sampling. Small sample sizes and high sample throughput result in significant increases in feasibility, cost effectiveness, and quality of data for a regional monitoring program. Similar results are expected for {sup 90}Sr.« less

  10. Quality of 99mTcO4- from 99Mo Produced by 100Mo(n,2n)99Mo

    NASA Astrophysics Data System (ADS)

    Nagai, Yasuki; Nakahara, Yuto; Kawabata, Masako; Hatsukawa, Yuichi; Hashimoto, Kazuyuki; Saeki, Hideya; Motoishi, Shoji; Ohta, Akio; Shiina, Takayuki; Kawauchi, Yukimasa

    2017-05-01

    The pharmaceutical quality of 99mTc pertechnetate solution obtained from 99Mo, the 100Mo(n,2n) reaction product, was investigated for the first time with an emphasis on the nonradioactive Mo content and endotoxin concentration. They were less than the tolerance dose given in international guidelines and the established upper limit in an international pharmacopoeia, respectively. Four other quality control tests commonly used for a commercially available 99mTc pertechnetate solution also demonstrated to meet the United States Pharmacopeia requirements. The results strongly support that the thermochromatographic separation method used to separate 99mTc from 99Mo can be a promising substitute for the fission product 99Mo.

  11. An on-chip coupled resonator optical waveguide single-photon buffer

    PubMed Central

    Takesue, Hiroki; Matsuda, Nobuyuki; Kuramochi, Eiichi; Munro, William J.; Notomi, Masaya

    2013-01-01

    Integrated quantum optical circuits are now seen as one of the most promising approaches with which to realize single-photon quantum information processing. Many of the core elements for such circuits have been realized, including sources, gates and detectors. However, a significant missing function necessary for photonic quantum information processing on-chip is a buffer, where single photons are stored for a short period of time to facilitate circuit synchronization. Here we report an on-chip single-photon buffer based on coupled resonator optical waveguides (CROW) consisting of 400 high-Q photonic crystal line-defect nanocavities. By using the CROW, a pulsed single photon is successfully buffered for 150 ps with 50-ps tunability while maintaining its non-classical properties. Furthermore, we show that our buffer preserves entanglement by storing and retrieving one photon from a time-bin entangled state. This is a significant step towards an all-optical integrated quantum information processor. PMID:24217422

  12. On-demand semiconductor single-photon source with near-unity indistinguishability.

    PubMed

    He, Yu-Ming; He, Yu; Wei, Yu-Jia; Wu, Dian; Atatüre, Mete; Schneider, Christian; Höfling, Sven; Kamp, Martin; Lu, Chao-Yang; Pan, Jian-Wei

    2013-03-01

    Single-photon sources based on semiconductor quantum dots offer distinct advantages for quantum information, including a scalable solid-state platform, ultrabrightness and interconnectivity with matter qubits. A key prerequisite for their use in optical quantum computing and solid-state networks is a high level of efficiency and indistinguishability. Pulsed resonance fluorescence has been anticipated as the optimum condition for the deterministic generation of high-quality photons with vanishing effects of dephasing. Here, we generate pulsed single photons on demand from a single, microcavity-embedded quantum dot under s-shell excitation with 3 ps laser pulses. The π pulse-excited resonance-fluorescence photons have less than 0.3% background contribution and a vanishing two-photon emission probability. Non-postselective Hong-Ou-Mandel interference between two successively emitted photons is observed with a visibility of 0.97(2), comparable to trapped atoms and ions. Two single photons are further used to implement a high-fidelity quantum controlled-NOT gate.

  13. [Course of ejection fraction, regurgitation fraction and ventricular volumes during exertion in chronic aortic insufficiency. Study using technetium 99m gamma-cineangiography].

    PubMed

    Bassand, J P; Faivre, R; Berthout, P; Cardot, J C; Verdenet, J; Bidet, R; Maurat, J P

    1985-06-01

    Previous studies have shown that variations of the ejection fraction (EF) during exercise were representative of the contractile state of the left ventricle: an increased EF on effort is considered to be physiological, whilst a decrease would indicate latent LV dysfunction unmasked during exercise. This hypothesis was tested by performing Technetium 99 gamma cineangiography at equilibrium under basal conditions and at maximal effort in 8 healthy subjects and 44 patients with pure, severe aortic regurgitation to measure the ejection and regurgitant fractions and the variations in end systolic and end diastolic LV volume. In the control group the EF increased and end systolic volume decreased significantly on effort whilst the regurgitant fraction and end diastolic volume were unchanged. In the 44 patients with aortic regurgitation no significant variations in EF, end systolic and end diastolic volumes were observed because the individual values were very dispersed. Variations of the EF and end systolic volume were inversely correlated. The regurgitant fraction decreased significantly on effort. Based on the variations of the EF and end systolic volume three different types of response to effort could be identified: in 7 patients, the EF increased on effort and end systolic volume decreased without any significant variation in the end diastolic volume, as in the group of normal control subjects; in 22 patients, a reduction in EF was observed on effort, associated with an increased end systolic volume. These changes indicated latent IV dysfunction inapparent at rest and unmasked by exercise; in a third group of 15 patients, the EF decreased on effort despite a physiological decrease in end systolic volume due to a greater decrease in end diastolic volume.(ABSTRACT TRUNCATED AT 250 WORDS)

  14. Neural Imaging Using Single-Photon Avalanche Diodes

    PubMed Central

    Karami, Mohammad Azim; Ansarian, Misagh

    2017-01-01

    Introduction: This paper analyses the ability of single-photon avalanche diodes (SPADs) for neural imaging. The current trend in the production of SPADs moves toward the minimum dark count rate (DCR) and maximum photon detection probability (PDP). Moreover, the jitter response which is the main measurement characteristic for the timing uncertainty is progressing. Methods: The neural imaging process using SPADs can be performed by means of florescence lifetime imaging (FLIM), time correlated single-photon counting (TCSPC), positron emission tomography (PET), and single-photon emission computed tomography (SPECT). Results: This trend will result in more precise neural imaging cameras. While achieving low DCR SPADs is difficult in deep submicron technologies because of using higher doping profiles, higher PDPs are reported in green and blue part of light. Furthermore, the number of pixels integrated in the same chip is increasing with the technology progress which can result in the higher resolution of imaging. Conclusion: This study proposes implemented SPADs in Deep-submicron technologies to be used in neural imaging cameras, due to the small size pixels and higher timing accuracies. PMID:28446946

  15. Slow light generation in single-mode rectangular core photonic crystal fiber

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yadav, Sandeep; Saini, Than Singh; Kumar, Ajeet, E-mail: ajeetdph@gmail.com

    2016-05-06

    In this paper, we have designed and analyzed a rectangular core photonic crystal fiber (PCF) in Tellurite material. For the designed photonics crystal fiber, we have calculated the values of confinement loss and effective mode area for different values of air filling fraction (d/Λ). For single mode operation of the designed photonic crystal fiber, we have taken d/Λ= 0.4 for the further calculation of stimulated Brillouin scattering based time delay. A maximum time delay of 158 ns has been achieved for input pump power of 39 mW. We feel the detailed theoretical investigations and simulations carried out in the study have themore » potential impact on the design and development of slow light-based photonic devices.« less

  16. Graphene-Based Josephson-Junction Single-Photon Detector

    NASA Astrophysics Data System (ADS)

    Walsh, Evan D.; Efetov, Dmitri K.; Lee, Gil-Ho; Heuck, Mikkel; Crossno, Jesse; Ohki, Thomas A.; Kim, Philip; Englund, Dirk; Fong, Kin Chung

    2017-08-01

    We propose to use graphene-based Josephson junctions (GJJs) to detect single photons in a wide electromagnetic spectrum from visible to radio frequencies. Our approach takes advantage of the exceptionally low electronic heat capacity of monolayer graphene and its constricted thermal conductance to its phonon degrees of freedom. Such a system could provide high-sensitivity photon detection required for research areas including quantum information processing and radio astronomy. As an example, we present our device concepts for GJJ single-photon detectors in both the microwave and infrared regimes. The dark count rate and intrinsic quantum efficiency are computed based on parameters from a measured GJJ, demonstrating feasibility within existing technologies.

  17. Single photon at a configurable quantum-memory-based beam splitter

    NASA Astrophysics Data System (ADS)

    Guo, Xianxin; Mei, Yefeng; Du, Shengwang

    2018-06-01

    We report the demonstration of a configurable coherent quantum-memory-based beam splitter (BS) for a single-photon wave packet making use of laser-cooled 85Rb atoms and electromagnetically induced transparency. The single-photon wave packet is converted (stored) into a collective atomic spin state and later retrieved (split) into two nearly opposing directions. The storage time, beam-splitting ratio, and relative phase are configurable and can be dynamically controlled. We experimentally confirm that such a BS preserves the quantum particle nature of the single photon and the coherence between the two split wave packets of the single photon.

  18. 99Tcm-MIBI single photon emission tomography (SPET) for detecting myocardial ischaemia and necrosis in patients with significant coronary artery disease.

    PubMed

    Sciammarella, M G; Fragasso, G; Gerundini, P; Maffioli, L; Cappelletti, A; Margonato, A; Savi, A; Chierchia, S

    1992-12-01

    The ability of 99Tcm-methoxyisobutylisonitrile (MIBI) single photon emission tomography (SPET) to detect myocardial ischaemia and necrosis was assessed in 56 patients (45 male, 11 female, aged 55 +/- 5 years), with clinically recognized ischaemic heart disease (IHD). All underwent coronary angiography (CA) and left ventriculography (LV). SPET images were obtained at rest and at peak exercise (Modified Bruce) 90 min after injection of 99Tcm-MIBI (650-850 MBq). Data were acquired in 30 min over 180 degrees (from 45 degrees RAO to 45 degrees LPO) with no correction for attenuation, using a 64 x 64 matrix. The presence of persistent (P) or reversible (R) perfusion defects (PD) was then correlated to the resting and exercise ECG and to the results of CA and LV. Of the 56 patients, 34 had reversible underperfusion (RPD), 46 persistent underperfusion (PPD) and 31 had both. The occurrence of RPD correlated well with the occurrence of exercise-induced ST segment depression and/or angina (27 patients of 34 patients, 79%) and with the presence of significant coronary artery disease (CAD) (33 of 44, 73%). In 45 of 46 patients (98%) PPD corresponded to akinetic or severely hypokinetic segments (LV) usually explored by ECG leads exhibiting diagnostic Q waves (42 of 46 patients, 91%). The scan was normal both at rest and after stress in four of 11 patients with no CAD, and in two of 45 patients with CAD. Finally, an abnormal resting scan was seen in seven of 11 patients with normal coronary arteries, of whom six had regional wall motion abnormalities.(ABSTRACT TRUNCATED AT 250 WORDS)

  19. Efficient room-temperature source of polarized single photons

    DOEpatents

    Lukishova, Svetlana G.; Boyd, Robert W.; Stroud, Carlos R.

    2007-08-07

    An efficient technique for producing deterministically polarized single photons uses liquid-crystal hosts of either monomeric or oligomeric/polymeric form to preferentially align the single emitters for maximum excitation efficiency. Deterministic molecular alignment also provides deterministically polarized output photons; using planar-aligned cholesteric liquid crystal hosts as 1-D photonic-band-gap microcavities tunable to the emitter fluorescence band to increase source efficiency, using liquid crystal technology to prevent emitter bleaching. Emitters comprise soluble dyes, inorganic nanocrystals or trivalent rare-earth chelates.

  20. On-Chip Waveguide Coupling of a Layered Semiconductor Single-Photon Source.

    PubMed

    Tonndorf, Philipp; Del Pozo-Zamudio, Osvaldo; Gruhler, Nico; Kern, Johannes; Schmidt, Robert; Dmitriev, Alexander I; Bakhtinov, Anatoly P; Tartakovskii, Alexander I; Pernice, Wolfram; Michaelis de Vasconcellos, Steffen; Bratschitsch, Rudolf

    2017-09-13

    Fully integrated quantum technology based on photons is in the focus of current research, because of its immense potential concerning performance and scalability. Ideally, the single-photon sources, the processing units, and the photon detectors are all combined on a single chip. Impressive progress has been made for on-chip quantum circuits and on-chip single-photon detection. In contrast, nonclassical light is commonly coupled onto the photonic chip from the outside, because presently only few integrated single-photon sources exist. Here, we present waveguide-coupled single-photon emitters in the layered semiconductor gallium selenide as promising on-chip sources. GaSe crystals with a thickness below 100 nm are placed on Si 3 N 4 rib or slot waveguides, resulting in a modified mode structure efficient for light coupling. Using optical excitation from within the Si 3 N 4 waveguide, we find nonclassicality of generated photons routed on the photonic chip. Thus, our work provides an easy-to-implement and robust light source for integrated quantum technology.