Sample records for technical performance evaluation

  1. Can We Predict Technical Aptitude?: A Systematic Review.

    PubMed

    Louridas, Marisa; Szasz, Peter; de Montbrun, Sandra; Harris, Kenneth A; Grantcharov, Teodor P

    2016-04-01

    To identify background characteristics and cognitive tests that may predict surgical trainees' future technical performance, and therefore be used to supplement existing surgical residency selection criteria. Assessment of technical skills is not commonly incorporated as part of the selection process for surgical trainees in North America. Emerging evidence, however, suggests that not all trainees are capable of reaching technical competence. Therefore, incorporating technical aptitude into selection processes may prove useful. A systematic search was carried out of the MEDLINE, PsycINFO, and Embase online databases to identify all studies that assessed associations between surrogate markers of innate technical abilities in surgical trainees, and whether these abilities correlate with technical performance. The quality of each study was evaluated using the Grading of Recommendations, Assessment, Development, and Evaluation system. A total of 8035 records were identified. After screening by title, abstract, and full text, 52 studies were included. Very few surrogate markers were found to predict technical performance. Significant associations with technical performance were seen for 1 of 23 participant-reported surrogate markers, 2 of 25 visual spatial tests, and 2 of 19 dexterity tests. The assessment of trainee Basic Performance Resources predicted technical performance in 62% and 75% of participants. To date, no single test has been shown to reliably predict the technical performance of surgical trainees. Strategies that rely on assessing multiple innate abilities, their interaction, and their relationship with technical skill may ultimately be more likely to serve as reliable predictors of future surgical performance.

  2. OrbView-3 Technical Performance Evaluation 2005: Modulation Transfer Function

    NASA Technical Reports Server (NTRS)

    Cole, Aaron

    2007-01-01

    The Technical performance evaluation of OrbView-3 using the Modulation Transfer Function (MTF) is presented. The contents include: 1) MTF Results and Methodology; 2) Radiometric Calibration Methodology; and 3) Relative Radiometric Assessment Results

  3. Full immersion simulation: validation of a distributed simulation environment for technical and non-technical skills training in Urology.

    PubMed

    Brewin, James; Tang, Jessica; Dasgupta, Prokar; Khan, Muhammad S; Ahmed, Kamran; Bello, Fernando; Kneebone, Roger; Jaye, Peter

    2015-07-01

    To evaluate the face, content and construct validity of the distributed simulation (DS) environment for technical and non-technical skills training in endourology. To evaluate the educational impact of DS for urology training. DS offers a portable, low-cost simulated operating room environment that can be set up in any open space. A prospective mixed methods design using established validation methodology was conducted in this simulated environment with 10 experienced and 10 trainee urologists. All participants performed a simulated prostate resection in the DS environment. Outcome measures included surveys to evaluate the DS, as well as comparative analyses of experienced and trainee urologist's performance using real-time and 'blinded' video analysis and validated performance metrics. Non-parametric statistical methods were used to compare differences between groups. The DS environment demonstrated face, content and construct validity for both non-technical and technical skills. Kirkpatrick level 1 evidence for the educational impact of the DS environment was shown. Further studies are needed to evaluate the effect of simulated operating room training on real operating room performance. This study has shown the validity of the DS environment for non-technical, as well as technical skills training. DS-based simulation appears to be a valuable addition to traditional classroom-based simulation training. © 2014 The Authors BJU International © 2014 BJU International Published by John Wiley & Sons Ltd.

  4. Performance Evaluation of Indian Technical Institutions Using PROMETHEE-GAIA Approach

    ERIC Educational Resources Information Center

    Ranjan, Rajeev; Chakraborty, Shankar

    2015-01-01

    It has now become an important issue to evaluate the performance of technical institutions to develop better research and enrich the existing teaching processes. The results of such performance appraisal would serve as a reference point for decisions to choose a particular institution, hire manpower, and provide financial support for the…

  5. Technical Evaluation Motor No. 7 (TEM-7)

    NASA Technical Reports Server (NTRS)

    Hughes, Phil

    1991-01-01

    The Technical Evaluation Motor No. 7 (TEM-7) test was a full-scale, full duration static test firing of a high performance motor-configuration solid rocket motor with nozzle vectoring. The final test report documents the procedures, performance, and results of the static test firing of TEM-7. All observations, discussions, conclusions, and recommendations included in the report are complete and final except for the TEM-7 fixed housing unbond investigation. A presentation and discussion of TEM-7 performance, anomalies, and test result concurrence with the objectives outlined in CTP-0107, Rev A, Space Shuttle Technical Evaluation Motor No. 7 (TEM-7) Static Fire Test Plan are included.

  6. Technical Evaluation Motor No. 10 (TEM-10)

    NASA Technical Reports Server (NTRS)

    1993-01-01

    Technical Evaluation Motor No. 10 (TEM-10) was static fired on 27 Apr. 1993 at the Thiokol Corporation full-scale motor static test bay, T-24. This final test report documents the procedures, performance, and results of the static test firing of TEM-10. All observations, discussions, conclusions, and recommendations contained are final. Included is a presentation and discussion of TEM-10 performance, anomalies, and test results in concurrence with the objectives outlined in CTP-0110, Revision D, Space Shuttle Technical Evaluation Motor No. 10 (TEM-10) Static Fire Test Plan.

  7. Technical Evaluation Motor No. 7 (TEM-07)

    NASA Technical Reports Server (NTRS)

    Hugh, Phil

    1991-01-01

    Technical Evaluation Motor Number 7 (TEM-7) was a full scale, full-duration static test firing of a high performance motor (HPM) configuration solid rocket motor (SRM) with nozzle vectoring. The static test fire occurred on 11 December 1990 at the Thiokol Corporation Static Test Bay T-97. Documented here are the procedures, performance, and results available through 22 January 1991. Critical post test hardware activities and assessment of the test data are not complete. A completed test report will be submitted 60 days after the test date. Included here is a presentation and discussion of the TEM-7 performance, anomalies, and test result concurrence with the objectives outlined in CTP-0107 Revision A, Space Shuttle Technical Evaluation Motor number 7 (TEM-07) Static Fire Test Plan.

  8. Non-technical skills evaluation in the critical care air ambulance environment: introduction of an adapted rating instrument--an observational study.

    PubMed

    Myers, Julia A; Powell, David M C; Psirides, Alex; Hathaway, Karyn; Aldington, Sarah; Haney, Michael F

    2016-03-08

    In the isolated and dynamic health-care setting of critical care air ambulance transport, the quality of clinical care is strongly influenced by non-technical skills such as anticipating, recognising and understanding, decision making, and teamwork. However there are no published reports identifying or applying a non-technical skills framework specific to an intensive care air ambulance setting. The objective of this study was to adapt and evaluate a non-technical skills rating framework for the air ambulance clinical environment. In the first phase of the project the anaesthetists' non-technical skills (ANTS) framework was adapted to the air ambulance setting, using data collected directly from clinician groups, published literature, and field observation. In the second phase experienced and inexperienced inter-hospital transport clinicians completed a simulated critical care air transport scenario, and their non-technical skills performance was independently rated by two blinded assessors. Observed and self-rated general clinical performance ratings were also collected. Rank-based statistical tests were used to examine differences in the performance of experienced and inexperienced clinicians, and relationships between different assessment approaches and assessors. The framework developed during phase one was referred to as an aeromedical non-technical skills framework, or AeroNOTS. During phase two 16 physicians from speciality training programmes in intensive care, emergency medicine and anaesthesia took part in the clinical simulation study. Clinicians with inter-hospital transport experience performed more highly than those without experience, according to both AeroNOTS non-technical skills ratings (p = 0.001) and general performance ratings (p = 0.003). Self-ratings did not distinguish experienced from inexperienced transport clinicians (p = 0.32) and were not strongly associated with either observed general performance (r(s) = 0.4, p = 0.11) or observed non-technical skills performance (r(s) = 0.4, p = 0.1). This study describes a framework which characterises the non-technical skills required by critical care air ambulance clinicians, and distinguishes higher and lower levels of performance. The AeroNOTS framework could be used to facilitate education and training in non-technical skills for air ambulance clinicians, and further evaluation of this rating system is merited.

  9. Predictive value of background experiences and visual spatial ability testing on laparoscopic baseline performance among residents entering postgraduate surgical training.

    PubMed

    Louridas, Marisa; Quinn, Lauren E; Grantcharov, Teodor P

    2016-03-01

    Emerging evidence suggests that despite dedicated practice, not all surgical trainees have the ability to reach technical competency in minimally invasive techniques. While selecting residents that have the ability to reach technical competence is important, evidence to guide the incorporation of technical ability into selection processes is limited. Therefore, the purpose of the present study was to evaluate whether background experiences and 2D-3D visual spatial test results are predictive of baseline laparoscopic skill for the novice surgical trainee. First-year residents were studied. Demographic data and background surgical and non-surgical experiences were obtained using a questionnaire. Visual spatial ability was evaluated using the PicSOr, cube comparison (CC) and card rotation (CR) tests. Technical skill was assessed using the camera navigation (LCN) task and laparoscopic circle cut (LCC) task. Resident performance on these technical tasks was compared and correlated with the questionnaire and visual spatial findings. Previous experience in observing laparoscopic procedures was associated with significantly better LCN performance, and experience in navigating the laparoscopic camera was associated with significantly better LCC task results. Residents who scored higher on the CC test demonstrated a more accurate LCN path length score (r s(PL) = -0.36, p = 0.03) and angle path (r s(AP) = -0.426, p = 0.01) score when completing the LCN task. No other significant correlations were found between the visual spatial tests (PicSOr, CC or CR) and LCC performance. While identifying selection tests for incoming surgical trainees that predict technical skill performance is appealing, the surrogate markers evaluated correlate with specific metrics of surgical performance related to a single task but do not appear to reliably predict technical performance of different laparoscopic tasks. Predicting the acquisition of technical skills will require the development of a series of evidence-based tests that measure a number of innate abilities as well as their inherent interactions.

  10. Metrology Standards for Quantitative Imaging Biomarkers

    PubMed Central

    Obuchowski, Nancy A.; Kessler, Larry G.; Raunig, David L.; Gatsonis, Constantine; Huang, Erich P.; Kondratovich, Marina; McShane, Lisa M.; Reeves, Anthony P.; Barboriak, Daniel P.; Guimaraes, Alexander R.; Wahl, Richard L.

    2015-01-01

    Although investigators in the imaging community have been active in developing and evaluating quantitative imaging biomarkers (QIBs), the development and implementation of QIBs have been hampered by the inconsistent or incorrect use of terminology or methods for technical performance and statistical concepts. Technical performance is an assessment of how a test performs in reference objects or subjects under controlled conditions. In this article, some of the relevant statistical concepts are reviewed, methods that can be used for evaluating and comparing QIBs are described, and some of the technical performance issues related to imaging biomarkers are discussed. More consistent and correct use of terminology and study design principles will improve clinical research, advance regulatory science, and foster better care for patients who undergo imaging studies. © RSNA, 2015 PMID:26267831

  11. Meta-analysis of the technical performance of an imaging procedure: guidelines and statistical methodology.

    PubMed

    Huang, Erich P; Wang, Xiao-Feng; Choudhury, Kingshuk Roy; McShane, Lisa M; Gönen, Mithat; Ye, Jingjing; Buckler, Andrew J; Kinahan, Paul E; Reeves, Anthony P; Jackson, Edward F; Guimaraes, Alexander R; Zahlmann, Gudrun

    2015-02-01

    Medical imaging serves many roles in patient care and the drug approval process, including assessing treatment response and guiding treatment decisions. These roles often involve a quantitative imaging biomarker, an objectively measured characteristic of the underlying anatomic structure or biochemical process derived from medical images. Before a quantitative imaging biomarker is accepted for use in such roles, the imaging procedure to acquire it must undergo evaluation of its technical performance, which entails assessment of performance metrics such as repeatability and reproducibility of the quantitative imaging biomarker. Ideally, this evaluation will involve quantitative summaries of results from multiple studies to overcome limitations due to the typically small sample sizes of technical performance studies and/or to include a broader range of clinical settings and patient populations. This paper is a review of meta-analysis procedures for such an evaluation, including identification of suitable studies, statistical methodology to evaluate and summarize the performance metrics, and complete and transparent reporting of the results. This review addresses challenges typical of meta-analyses of technical performance, particularly small study sizes, which often causes violations of assumptions underlying standard meta-analysis techniques. Alternative approaches to address these difficulties are also presented; simulation studies indicate that they outperform standard techniques when some studies are small. The meta-analysis procedures presented are also applied to actual [18F]-fluorodeoxyglucose positron emission tomography (FDG-PET) test-retest repeatability data for illustrative purposes. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  12. Meta-analysis of the technical performance of an imaging procedure: Guidelines and statistical methodology

    PubMed Central

    Huang, Erich P; Wang, Xiao-Feng; Choudhury, Kingshuk Roy; McShane, Lisa M; Gönen, Mithat; Ye, Jingjing; Buckler, Andrew J; Kinahan, Paul E; Reeves, Anthony P; Jackson, Edward F; Guimaraes, Alexander R; Zahlmann, Gudrun

    2017-01-01

    Medical imaging serves many roles in patient care and the drug approval process, including assessing treatment response and guiding treatment decisions. These roles often involve a quantitative imaging biomarker, an objectively measured characteristic of the underlying anatomic structure or biochemical process derived from medical images. Before a quantitative imaging biomarker is accepted for use in such roles, the imaging procedure to acquire it must undergo evaluation of its technical performance, which entails assessment of performance metrics such as repeatability and reproducibility of the quantitative imaging biomarker. Ideally, this evaluation will involve quantitative summaries of results from multiple studies to overcome limitations due to the typically small sample sizes of technical performance studies and/or to include a broader range of clinical settings and patient populations. This paper is a review of meta-analysis procedures for such an evaluation, including identification of suitable studies, statistical methodology to evaluate and summarize the performance metrics, and complete and transparent reporting of the results. This review addresses challenges typical of meta-analyses of technical performance, particularly small study sizes, which often causes violations of assumptions underlying standard meta-analysis techniques. Alternative approaches to address these difficulties are also presented; simulation studies indicate that they outperform standard techniques when some studies are small. The meta-analysis procedures presented are also applied to actual [18F]-fluorodeoxyglucose positron emission tomography (FDG-PET) test–retest repeatability data for illustrative purposes. PMID:24872353

  13. Is Beauty in the Eyes of the Beholder? Aesthetic Quality versus Technical Skill in Movement Evaluation of Tai Chi.

    PubMed

    Zamparo, Paola; Zorzi, Elena; Marcantoni, Sara; Cesari, Paola

    2015-01-01

    The aim of this study was to compare experts to naïve practitioners in rating the beauty and the technical quality of a Tai Chi sequence observed in video-clips (of high and middle level performances). Our hypothesis are: i) movement evaluation will correlate with the level of skill expressed in the kinematics of the observed action but ii) only experts will be able to unravel the technical component from the aesthetic component of the observed action. The judgments delivered indicate that both expert and non-expert observers are able to discern a good from a mediocre performance; however, as expected, only experts discriminate the technical from the aesthetic component of the action evaluated and do this independently of the level of skill shown by the model (high or middle level performances). Furthermore, the judgments delivered were strongly related to the kinematic variables measured in the observed model, indicating that observers rely on specific movement kinematics (e.g. movement amplitude, jerk and duration) for action evaluation. These results provide evidence of the complementary functional role of visual and motor action representation in movement evaluation and underline the role of expertise in judging the aesthetic quality of movements.

  14. Is Beauty in the Eyes of the Beholder? Aesthetic Quality versus Technical Skill in Movement Evaluation of Tai Chi

    PubMed Central

    2015-01-01

    The aim of this study was to compare experts to naïve practitioners in rating the beauty and the technical quality of a Tai Chi sequence observed in video-clips (of high and middle level performances). Our hypothesis are: i) movement evaluation will correlate with the level of skill expressed in the kinematics of the observed action but ii) only experts will be able to unravel the technical component from the aesthetic component of the observed action. The judgments delivered indicate that both expert and non-expert observers are able to discern a good from a mediocre performance; however, as expected, only experts discriminate the technical from the aesthetic component of the action evaluated and do this independently of the level of skill shown by the model (high or middle level performances). Furthermore, the judgments delivered were strongly related to the kinematic variables measured in the observed model, indicating that observers rely on specific movement kinematics (e.g. movement amplitude, jerk and duration) for action evaluation. These results provide evidence of the complementary functional role of visual and motor action representation in movement evaluation and underline the role of expertise in judging the aesthetic quality of movements. PMID:26047473

  15. Do technical skills correlate with non-technical skills in crisis resource management: a simulation study.

    PubMed

    Riem, N; Boet, S; Bould, M D; Tavares, W; Naik, V N

    2012-11-01

    Both technical skills (TS) and non-technical skills (NTS) are key to ensuring patient safety in acute care practice and effective crisis management. These skills are often taught and assessed separately. We hypothesized that TS and NTS are not independent of each other, and we aimed to evaluate the relationship between TS and NTS during a simulated intraoperative crisis scenario. This study was a retrospective analysis of performances from a previously published work. After institutional ethics approval, 50 anaesthesiology residents managed a simulated crisis scenario of an intraoperative cardiac arrest secondary to a malignant arrhythmia. We used a modified Delphi approach to design a TS checklist, specific for the management of a malignant arrhythmia requiring defibrillation. All scenarios were recorded. Each performance was analysed by four independent experts. For each performance, two experts independently rated the technical performance using the TS checklist, and two other experts independently rated NTS using the Anaesthetists' Non-Technical Skills score. TS and NTS were significantly correlated to each other (r=0.45, P<0.05). During a simulated 5 min resuscitation requiring crisis resource management, our results indicate that TS and NTS are related to one another. This research provides the basis for future studies evaluating the nature of this relationship, the influence of NTS training on the performance of TS, and to determine whether NTS are generic and transferrable between crises that require different TS.

  16. AgRISTARS. Preliminary technical results review of FY81 experiments, volume 2: Fiscal year 1981/1982 "corn and soybeans pilot" experiment

    NASA Technical Reports Server (NTRS)

    1981-01-01

    The performance of the technology exhibited significant proportion estimation errors, specifically, high mean error in both corn and soybeans area estimation. The data systems, technical approaches, and data assessment of the pilot experiment were reviewed. Results of proportion estimations procedure performance evaluations, and sensitivity evaluations are presented. The role of the pilot experiment in foreign technology development is discussed.

  17. Evaluating Instructor Technology Integration in Community and Technical Colleges: A Performance Evaluation Matrix

    ERIC Educational Resources Information Center

    Del Favero, Marietta; Hinson, Janice M.

    2007-01-01

    The press for implementing technology based instructional delivery systems in community and technical colleges is well documented. Yet faculty face numerous challenges in integrating technology into instruction (AL-Bataineh & Brooks, 2003; Groves & Zemel, 2000; Khoury, 1997). Stimulating faculty ownership in technology, diffusion of technology use…

  18. Faculty Performance Management System: The Faculty Development/Evaluation System at Beaufort Technical College, 1986-1987. Revised.

    ERIC Educational Resources Information Center

    Tobias, Earole; And Others

    Designed for faculty members at Beaufort Technical College (BTC) in South Carolina, this handbook describes the college's faculty evaluation process and procedures. The first sections of the handbook explain the rationale and method for the faculty evaluation process, state the purposes and objectives of the system, and offer a model which breaks…

  19. Relationship between Procedural Tactical Knowledge and Specific Motor Skills in Young Soccer Players

    PubMed Central

    Aquino, Rodrigo; Marques, Renato Francisco R.; Petiot, Grégory Hallé; Gonçalves, Luiz Guilherme C.; Moraes, Camila; Santiago, Paulo Roberto P.; Puggina, Enrico Fuini

    2016-01-01

    The purpose of this study was to investigate the association between offensive tactical knowledge and the soccer-specific motor skills performance. Fifteen participants were submitted to two evaluation tests, one to assess their technical and tactical analysis. The motor skills performance was measured through four tests of technical soccer skills: ball control, shooting, passing and dribbling. The tactical performance was based on a tactical assessment system called FUT-SAT (Analyses of Procedural Tactical Knowledge in Soccer). Afterwards, technical and tactical evaluation scores were ranked with and without the use of the cluster method. A positive, weak correlation was perceived in both analyses (rho = 0.39, not significant p = 0.14 (with cluster analysis); and rho = 0.35; not significant p = 0.20 (without cluster analysis)). We can conclude that there was a weak association between the technical and the offensive tactical knowledge. This shows the need to reflect on the use of such tests to assess technical skills in team sports since they do not take into account the variability and unpredictability of game actions and disregard the inherent needs to assess such skill performance in the game. PMID:29910300

  20. A new global and comprehensive model for ICU ventilator performances evaluation.

    PubMed

    Marjanovic, Nicolas S; De Simone, Agathe; Jegou, Guillaume; L'Her, Erwan

    2017-12-01

    This study aimed to provide a new global and comprehensive evaluation of recent ICU ventilators taking into account both technical performances and ergonomics. Six recent ICU ventilators were evaluated. Technical performances were assessed under two FIO 2 levels (100%, 50%), three respiratory mechanics combinations (Normal: compliance [C] = 70 mL cmH 2 O -1 /resistance [R] = 5 cmH 2 O L -1  s -1 ; Restrictive: C = 30/R = 10; Obstructive: C = 120/R = 20), four exponential levels of leaks (from 0 to 12.5 L min -1 ) and three levels of inspiratory effort (P0.1 = 2, 4 and 8 cmH 2 O), using an automated test lung. Ergonomics were evaluated by 20 ICU physicians using a global and comprehensive model involving physiological response to stress measurements (heart rate, respiratory rate, tidal volume variability and eye tracking), psycho-cognitive scales (SUS and NASA-TLX) and objective tasks completion. Few differences in terms of technical performance were observed between devices. Non-invasive ventilation modes had a huge influence on asynchrony occurrence. Using our global model, either objective tasks completion, psycho-cognitive scales and/or physiological measurements were able to depict significant differences in terms of devices' usability. The level of failure that was observed with some devices depicted the lack of adaptation of device's development to end users' requests. Despite similar technical performance, some ICU ventilators exhibit low ergonomics performance and a high risk of misusage.

  1. 77 FR 45282 - NRC Position on the Relationship Between General Design Criteria and Technical Specification...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-31

    ..., are described in the final safety analysis report (FSAR). The staff safety evaluation documents the acceptability of these analyses, and it is the combination of the FSAR analyses and the staff safety evaluation... analysis, maintain their capability to perform their safety functions. Technical Specification Operability...

  2. Integration of role-playing into technical skills training: a randomized controlled trial.

    PubMed

    Nikendei, C; Kraus, B; Schrauth, M; Weyrich, P; Zipfel, S; Herzog, W; Jünger, J

    2007-11-01

    Recently, efforts have been undertaken to enhance the face validity of technical skills training by introducing role-plays and standardised patients. Since little is known about the effects of role-playing with respect to the realism of a training situation and students' objective performance, we performed a randomized controlled trial. 36 medical students participated in videotaped small group skills-lab sessions on the topics of Doppler sonography and gastric tube insertion. One half of the students participated in role-plays and the other half practised without role-playing. Realism of the training situation was analysed by means of post-intervention self-selected student survey evaluations. Technical performance and patient-physician communication were assessed by independent ratings of the videotaped sessions. The physician's role was regarded to be significantly more realistic when performing role-plays. Assessment of videotaped sessions showed that practising technical skills by performing role-plays resulted in significantly better patient-physician communication whereas students' technical performance did not differ between groups. Introducing role-plays enhances the realism of technical skills training and leads to better patient-physician communication. Students do not seem to be overstrained by practising clinical technical skills using role-plays. We conclude that role-playing is a valuable method in practising technical skills.

  3. Peer Review of a Formal Verification/Design Proof Methodology

    NASA Technical Reports Server (NTRS)

    1983-01-01

    The role of formal verification techniques in system validation was examined. The value and the state of the art of performance proving for fault-tolerant compuers were assessed. The investigation, development, and evaluation of performance proving tools were reviewed. The technical issues related to proof methodologies are examined. The technical issues discussed are summarized.

  4. Non-technical skills assessment in surgery.

    PubMed

    Sharma, Bharat; Mishra, Amit; Aggarwal, Rajesh; Grantcharov, Teodor P

    2011-09-01

    Adverse events in surgery have highlighted the importance of non-technical skills, such as communication, decision-making, teamwork, situational awareness and leadership, to effective organizational performance. These skills carry particular importance to surgical oncology, as members of a multidisciplinary team must work cohesively to formulate effective patient care plans. Several non-technical skills evaluation tools have been developed for use in surgery, without adequate comparison and consensus on which should be standard for training. Eleven articles describing the use of three non-technical evaluation tools related to surgery: NOTSS (Non Technical Skills for Surgeons), NOTECHS (Non Technical Skills) and OTAS (Observational Teamwork Assessment for Surgery) were analyzed with respect to scale formulation, validity, reliability and feasibility. Furthermore, their use in training thus far and the future of non-technical rating scales in surgical curricula was discussed. Future work should focus on incorporating these assessment tools into training and into a real operating room setting to provide formative evaluations for surgical residents. Copyright © 2010 Elsevier Ltd. All rights reserved.

  5. An Annotated Bibliography of MANPRINT-Related Assessments and Evaluations Conducted by the U.S. Army, 2nd Edition: 1953 to 2009. Volume 3 - Test and Evaluation Reports

    DTIC Science & Technology

    2010-02-01

    bibliography of the 583 MA reports reviewed by this paper . MANPRINT Asssessments are performed according to the direction of AR 602-2. They consist of an...bibliography of the 443 T&ERs reviewed by this paper . A T&ER is a system evaluation performed according to AR 73-1 for all systems in development in the...of the Defense Technical Information Center (DTIC) web page: https://dtic-stinet.dtic.mil/.  National Technical Information Service (NTIS): http

  6. 13 CFR 306.7 - Performance evaluations of University Centers.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... University Centers. 306.7 Section 306.7 Business Credit and Assistance ECONOMIC DEVELOPMENT ADMINISTRATION, DEPARTMENT OF COMMERCE TRAINING, RESEARCH AND TECHNICAL ASSISTANCE INVESTMENTS University Center Economic Development Program § 306.7 Performance evaluations of University Centers. (a) EDA will: (1) Evaluate each...

  7. 13 CFR 306.7 - Performance evaluations of University Centers.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... University Centers. 306.7 Section 306.7 Business Credit and Assistance ECONOMIC DEVELOPMENT ADMINISTRATION, DEPARTMENT OF COMMERCE TRAINING, RESEARCH AND TECHNICAL ASSISTANCE INVESTMENTS University Center Economic Development Program § 306.7 Performance evaluations of University Centers. (a) EDA will: (1) Evaluate each...

  8. 13 CFR 306.7 - Performance evaluations of University Centers.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... University Centers. 306.7 Section 306.7 Business Credit and Assistance ECONOMIC DEVELOPMENT ADMINISTRATION, DEPARTMENT OF COMMERCE TRAINING, RESEARCH AND TECHNICAL ASSISTANCE INVESTMENTS University Center Economic Development Program § 306.7 Performance evaluations of University Centers. (a) EDA will: (1) Evaluate each...

  9. 13 CFR 306.7 - Performance evaluations of University Centers.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... University Centers. 306.7 Section 306.7 Business Credit and Assistance ECONOMIC DEVELOPMENT ADMINISTRATION, DEPARTMENT OF COMMERCE TRAINING, RESEARCH AND TECHNICAL ASSISTANCE INVESTMENTS University Center Economic Development Program § 306.7 Performance evaluations of University Centers. (a) EDA will: (1) Evaluate each...

  10. Transferring Codified Knowledge: Socio-Technical versus Top-Down Approaches

    ERIC Educational Resources Information Center

    Guzman, Gustavo; Trivelato, Luiz F.

    2008-01-01

    Purpose: This paper aims to analyse and evaluate the transfer process of codified knowledge (CK) performed under two different approaches: the "socio-technical" and the "top-down". It is argued that the socio-technical approach supports the transfer of CK better than the top-down approach. Design/methodology/approach: Case study methodology was…

  11. Mariano Lake Mine: Technical Reports

    EPA Pesticide Factsheets

    This Final Removal Site Evaluation describes the objectives, work performed, and results of a Removal Site Evaluation (RSE) at the Mariano Lake Mine, which was performed by ARCADIS U.S., Inc. on behalf of Chevron Environmental Management Company.

  12. Evaluating Performance of Highway Safety Projects

    DOT National Transportation Integrated Search

    2016-12-01

    The purpose of this project was to investigate and document methods that the Idaho Transportation Department (ITD) and Local Highway Technical Assistance Council (LHTAC) can use to evaluate the performance of safety projects that have been implemente...

  13. Does teaching non-technical skills to medical students improve those skills and simulated patient outcome?

    PubMed

    Hagemann, Vera; Herbstreit, Frank; Kehren, Clemens; Chittamadathil, Jilson; Wolfertz, Sandra; Dirkmann, Daniel; Kluge, Annette; Peters, Jürgen

    2017-03-29

    The purpose of this study is to evaluate the effects of a tailor-made, non-technical skills seminar on medical student's behaviour, attitudes, and performance during simulated patient treatment. Seventy-seven students were randomized to either a non-technical skills seminar (NTS group, n=43) or a medical seminar (control group, n=34). The human patient simulation was used as an evaluation tool. Before the seminars, all students performed the same simulated emergency scenario to provide baseline measurements. After the seminars, all students were exposed to a second scenario, and behavioural markers for evaluating their non-technical skills were rated. Furthermore, teamwork-relevant attitudes were measured before and after the scenarios, and perceived stress was measured following each simulation. All simulations were also evaluated for various medical endpoints. Non-technical skills concerning situation awareness (p<.01, r=0.5) and teamwork (p<.01, r=0.45) improved from simulation I to II in the NTS group. Decision making improved in both groups (NTS: p<.01, r=0.39; control: p<.01, r=0.46). The attitude 'handling errors' improved significantly in the NTS group (p<.05, r=0.34). Perceived stress decreased from simulation I to II in both groups. Medical endpoints and patients´ outcome did not differ significantly between the groups in simulation II. This study highlights the effectiveness of a single brief seminar on non-technical skills to improve student's non-technical skills. In a next step, to improve student's handling of emergencies and patient outcomes, non-technical skills seminars should be accompanied by exercises and more broadly embedded in the medical school curriculum.

  14. Performance Evaluation of Technical Institutions: An Application of Data Envelopment Analysis

    ERIC Educational Resources Information Center

    Debnath, Roma Mitra; Shankar, Ravi; Kumar, Surender

    2008-01-01

    Technical institutions (TIs) are playing an important role in making India a knowledge hub of this century. There is still great diversity in their relative performance, which is a matter of concern to the education planner. This article employs the method of data envelopment analysis (DEA) to compare the relative efficiency of TIs in India. The…

  15. Accomplishments and challenges of surgical simulation.

    PubMed

    Satava, R M

    2001-03-01

    For nearly a decade, advanced computer technologies have created extraordinary educational tools using three-dimensional (3D) visualization and virtual reality. Pioneering efforts in surgical simulation with these tools have resulted in a first generation of simulators for surgical technical skills. Accomplishments include simulations with 3D models of anatomy for practice of surgical tasks, initial assessment of student performance in technical skills, and awareness by professional societies of potential in surgical education and certification. However, enormous challenges remain, which include improvement of technical fidelity, standardization of accurate metrics for performance evaluation, integration of simulators into a robust educational curriculum, stringent evaluation of simulators for effectiveness and value added to surgical training, determination of simulation application to certification of surgical technical skills, and a business model to implement and disseminate simulation successfully throughout the medical education community. This review looks at the historical progress of surgical simulators, their accomplishments, and the challenges that remain.

  16. Evaluating SPP/APR Improvement Activities

    ERIC Educational Resources Information Center

    National Early Childhood Technical Assistance Center (NECTAC), 2009

    2009-01-01

    This document is intended to assist State Education Agency (SEA) and Lead Agency (LA) staff and technical assistance providers in designing a meaningful evaluation for the State Performance Plan (SPP)/Annual Performance Report (APR) improvement activities. It provides: (1) information about the relevance of evaluation in the context of improvement…

  17. Radiographic technical quality of root canal treatment performed ex vivo by dental students at Valencia University Medical and Dental School, Spain

    PubMed Central

    Faus-Matoses, Vicente; Alegre-Domingo, Teresa; Faus-Llácer, Vicente J.

    2014-01-01

    Objectives: To evaluate radiographically the quality of root canal fillings and compare manual and rotary preparation performed on extracted teeth by undergraduate dental students. Study Design: A total of 561 premolars and molars extracted teeth were prepared using nickel-titanium rotary files or manual instrumentation and filled with gutta-percha using a cold lateral condensation technique, by 4th grade undergraduate students. Periapical radiographs were used to assess the technical quality of the root canal filling, evaluating three variables: length, density and taper. These data were recorded, scored and used to study the “technical success rate” and the “overall score”. The length of each root canal filling was classified as acceptable, short and overfilled, based on their relationship with the radiographic apex. Density and taper of filling were evaluated based on the presence of voids and the uniform tapering of the filling, respectively. Statistical analysis was used to evaluate the quality of root canal treatment, considering p < 0.05 as a statistical significant level. Results: The percentage of technical success was 44% and the overall score was 7.8 out of 10. Technical success and overall score were greater with rotary instruments (52% against 28% with a manual one, p < 0.001; 8.3 against 6.7 respectively, p < 0.001). Conclusions: It appears that inexperienced operators perform better root canal treatment (RCT) with the use of rotary instrumentation. Key words:Dental education, endodontics, rotary instrumentation, radiographs, root canal treatment, undergraduate students. PMID:24121911

  18. The impact of nontechnical skills on technical performance in surgery: a systematic review.

    PubMed

    Hull, Louise; Arora, Sonal; Aggarwal, Rajesh; Darzi, Ara; Vincent, Charles; Sevdalis, Nick

    2012-02-01

    Failures in nontechnical and teamwork skills frequently lie at the heart of harm and near-misses in the operating room (OR). The purpose of this systematic review was to assess the impact of nontechnical skills on technical performance in surgery. MEDLINE, EMBASE, PsycINFO databases were searched, and 2,041 articles were identified. After limits were applied, 341 articles were retrieved for evaluation. Of these, 28 articles were accepted for this review. Data were extracted from the articles regarding sample population, study design and setting, measures of nontechnical skills and technical performance, study findings, and limitations. Of the 28 articles that met inclusion criteria, 21 articles assessed the impact of surgeons' nontechnical skills on their technical performance. The evidence suggests that receiving feedback and effectively coping with stressful events in the OR has a beneficial impact on certain aspects of technical performance. Conversely, increased levels of fatigue are associated with detriments to surgical skill. One article assessed the impact of anesthesiologists' nontechnical skills on anesthetic technical performance, finding a strong positive correlation between the 2 skill sets. Finally, 6 articles assessed the impact of multiple nontechnical skills of the entire OR team on surgical performance. A strong relationship between teamwork failure and technical error was empirically demonstrated in these studies. Evidence suggests that certain nontechnical aspects of performance can enhance or, if lacking, contribute to deterioration of surgeons' technical performance. The precise extent of this effect remains to be elucidated. Copyright © 2012 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  19. GENERAL METHODS FOR REMEDIAL PERFORMANCE EVALUATIONS

    EPA Science Inventory

    This document was developed by an EPA-funded project to explain technical considerations and principles necessary to evaluated the performance of ground-water contamination remediations at hazardous waste sites. This is neither a "cookbook", nor an encyclopedia of recommended fi...

  20. The Effect of Technical Performance on Patient Outcomes in Surgery: A Systematic Review.

    PubMed

    Fecso, Andras B; Szasz, Peter; Kerezov, Georgi; Grantcharov, Teodor P

    2017-03-01

    Systematic review of the effect of intraoperative technical performance on patient outcomes. The operating room is a high-stakes, high-risk environment. As a result, the quality of surgical interventions affecting patient outcomes has been the subject of discussion and research for years. MEDLINE, EMBASE, PsycINFO, and Cochrane databases were searched. All surgical specialties were eligible for inclusion. Data were reviewed in regards to the methods by which technical performance was measured, what patient outcomes were assessed, and how intraoperative technical performance affected patient outcomes. Quality of evidence was assessed using the Medical Education Research Study Quality Instrument (MERSQI). Of the 12,758 studies initially identified, 24 articles (7775 total participants) were ultimately included in this review. Seventeen studies assessed the performance of the faculty alone, 2 assessed both the faculty and trainees, 1 assessed trainees alone, and in 4 studies, the level of the operating surgeon was not specified. In 18 studies, a performance assessment tool was used. Patient outcomes were evaluated using intraoperative complications, short-term morbidity, long-term morbidity, short-term mortality, and long-term mortality. The average MERSQI score was 11.67 (range 9.5-14.5). Twenty-one studies demonstrated that superior technical performance was related to improved patient outcomes. The results of this systematic review demonstrated that superior technical performance positively affects patient outcomes. Despite this initial evidence, more robust research is needed to directly assess intraoperative technical performance and its effect on postoperative patient outcomes using meaningful assessment instruments and reliable processes.

  1. Personality traits and virtual reality performance.

    PubMed

    Rosenthal, Rachel; Schäfer, Juliane; Hoffmann, Henry; Vitz, Martina; Oertli, Daniel; Hahnloser, Dieter

    2013-01-01

    Surgeons' personalities have been described as different from those of the general population, but this was based on small descriptive studies limited by the choice of evaluation instrument. Furthermore, although the importance of the human factor in team performance has been recognized, the effect of personality traits on technical performance is unknown. This study aimed to compare surgical residents' personality traits with those of the general population and to evaluate whether an association exists between their personality traits and technical performance using a virtual reality (VR) laparoscopy simulator. In this study, 95 participants (54 residents with basic, 29 with intermediate laparoscopic experience, and 12 students) underwent personality assessment using the NEO-Five Factor Inventory and performed five VR tasks of the Lap Mentor™ basic tasks module. The residents' personality traits were compared with those of the general population, and the association between VR performance and personality traits was investigated. Surgical residents showed personality traits different from those of the general population, demonstrating lower neuroticism, higher extraversion and conscientiousness, and male residents showed greater openness. In the multivariable analysis, adjusted for gender and surgical experience, none of the personality traits was found to be an independent predictor of technical performance. Surgical residents present distinct personality traits that differ from those of the general population. These traits were not found to be associated with technical performance in a virtual environment. The traits may, however, play an important role in team performance, which in turn is highly relevant for optimal surgical performance.

  2. Evaluation of the Anaheim Advanced Traffic Control System Field Operational Test : introduction and Task A : evaluation of SCOOT performance

    DOT National Transportation Integrated Search

    1999-03-01

    This report provides an overview of both the Anaheim Advanced Traffic Control System Field Operations Test (FOT) and of the technical issues associated with the evaluation of SCOOT performance during the test. The primary objective of the FOT was to ...

  3. Wind Energy Conversion System Analysis Model (WECSAM) computer program documentation

    NASA Astrophysics Data System (ADS)

    Downey, W. T.; Hendrick, P. L.

    1982-07-01

    Described is a computer-based wind energy conversion system analysis model (WECSAM) developed to predict the technical and economic performance of wind energy conversion systems (WECS). The model is written in CDC FORTRAN V. The version described accesses a data base containing wind resource data, application loads, WECS performance characteristics, utility rates, state taxes, and state subsidies for a six state region (Minnesota, Michigan, Wisconsin, Illinois, Ohio, and Indiana). The model is designed for analysis at the county level. The computer model includes a technical performance module and an economic evaluation module. The modules can be run separately or together. The model can be run for any single user-selected county within the region or looped automatically through all counties within the region. In addition, the model has a restart capability that allows the user to modify any data-base value written to a scratch file prior to the technical or economic evaluation.

  4. Assurance Policy Evaluation - Spacecraft and Strategic Systems

    DTIC Science & Technology

    2014-09-17

    electromechanical (EEE) parts, software, design and workmanship, work instructions, manufacturing and tooling, cleanrooms, electrostatic discharge ...T9001B.  An external group, called the Evaluation and Assessment Team, made up of product assurance subject matter experts from NSWC Corona performs...NSWC, Corona and SSP Technical Branch(es). The FTPE, performed every 3 years, is an objective evaluation of facility performance to assure proper

  5. Review of Final Year MSP Evaluations, Performance Period 2007. Analytic and Technical Support for Mathematics and Science Partnerships

    ERIC Educational Resources Information Center

    Bobronnikov, Ellen; Rhodes, Hilary; Bradley, Cay

    2010-01-01

    This final report culminates the evaluation and technical assistance provided for the U.S. Department of Education's Mathematics and Science Partnership (MSP) Program and its projects since 2005. As part of this support, Abt Associates looked across the portfolio of projects funded by the MSP program to draw lessons on best practices. This…

  6. The Accreditation Experience of Clinical Laboratories and Blood Banks in Mexico.

    PubMed

    Quintana, Sandra

    2015-11-01

    The accreditation of clinical laboratories and blood banks based on ISO 15189 is now being consolidated in Mexico, and is coordinated by the Mexican accreditation entity innovative strategies, A.C. (ema) and supported by the activities of the committee of clinical laboratories and blood banks. The active participation in working groups formed by the technical committee of clinical laboratories and blood banks in specific areas, has contributed to the formulation of technical documents and criteria of evaluation that strengthen the current accreditation scheme. The national registry of evaluation (PNE) consists of technical experts and evaluators from different disciplines of clinical laboratory; the evaluators actively participate in accreditation assessment, with an ultimate goal to receive training and feedback for continuous improvement of its own performance.

  7. Assessing technical performance in differential gene expression experiments with external spike-in RNA control ratio mixtures.

    PubMed

    Munro, Sarah A; Lund, Steven P; Pine, P Scott; Binder, Hans; Clevert, Djork-Arné; Conesa, Ana; Dopazo, Joaquin; Fasold, Mario; Hochreiter, Sepp; Hong, Huixiao; Jafari, Nadereh; Kreil, David P; Łabaj, Paweł P; Li, Sheng; Liao, Yang; Lin, Simon M; Meehan, Joseph; Mason, Christopher E; Santoyo-Lopez, Javier; Setterquist, Robert A; Shi, Leming; Shi, Wei; Smyth, Gordon K; Stralis-Pavese, Nancy; Su, Zhenqiang; Tong, Weida; Wang, Charles; Wang, Jian; Xu, Joshua; Ye, Zhan; Yang, Yong; Yu, Ying; Salit, Marc

    2014-09-25

    There is a critical need for standard approaches to assess, report and compare the technical performance of genome-scale differential gene expression experiments. Here we assess technical performance with a proposed standard 'dashboard' of metrics derived from analysis of external spike-in RNA control ratio mixtures. These control ratio mixtures with defined abundance ratios enable assessment of diagnostic performance of differentially expressed transcript lists, limit of detection of ratio (LODR) estimates and expression ratio variability and measurement bias. The performance metrics suite is applicable to analysis of a typical experiment, and here we also apply these metrics to evaluate technical performance among laboratories. An interlaboratory study using identical samples shared among 12 laboratories with three different measurement processes demonstrates generally consistent diagnostic power across 11 laboratories. Ratio measurement variability and bias are also comparable among laboratories for the same measurement process. We observe different biases for measurement processes using different mRNA-enrichment protocols.

  8. Evaluation of world's largest social welfare scheme: An assessment using non-parametric approach.

    PubMed

    Singh, Sanjeet

    2016-08-01

    Mahatma Gandhi National Rural Employment Guarantee Act (MGNREGA) is the world's largest social welfare scheme in India for the poverty alleviation through rural employment generation. This paper aims to evaluate and rank the performance of the states in India under MGNREGA scheme. A non-parametric approach, Data Envelopment Analysis (DEA) is used to calculate the overall technical, pure technical, and scale efficiencies of states in India. The sample data is drawn from the annual official reports published by the Ministry of Rural Development, Government of India. Based on three selected input parameters (expenditure indicators) and five output parameters (employment generation indicators), I apply both input and output oriented DEA models to estimate how well the states utilize their resources and generate outputs during the financial year 2013-14. The relative performance evaluation has been made under the assumption of constant returns and also under variable returns to scale to assess the impact of scale on performance. The results indicate that the main source of inefficiency is both technical and managerial practices adopted. 11 states are overall technically efficient and operate at the optimum scale whereas 18 states are pure technical or managerially efficient. It has been found that for some states it necessary to alter scheme size to perform at par with the best performing states. For inefficient states optimal input and output targets along with the resource savings and output gains are calculated. Analysis shows that if all inefficient states operate at optimal input and output levels, on an average 17.89% of total expenditure and a total amount of $780million could have been saved in a single year. Most of the inefficient states perform poorly when it comes to the participation of women and disadvantaged sections (SC&ST) in the scheme. In order to catch up with the performance of best performing states, inefficient states on an average need to enhance women participation by 133%. In addition, the states are also ranked using the cross efficiency approach and results are analyzed. State of Tamil Nadu occupies the top position followed by Puducherry, Punjab, and Rajasthan in the ranking list. To the best of my knowledge, this is the first pan-India level study to evaluate and rank the performance of MGNREGA scheme quantitatively and so comprehensively. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Randomized controlled trial of multidisciplinary team stress and performance in immersive simulation for management of infant in shock: study protocol.

    PubMed

    Ghazali, Daniel Aiham; Ragot, Stéphanie; Breque, Cyril; Guechi, Youcef; Boureau-Voultoury, Amélie; Petitpas, Franck; Oriot, Denis

    2016-03-25

    Human error and system failures continue to play a substantial role in adverse outcomes in healthcare. Simulation improves management of patients in critical condition, especially if it is undertaken by a multidisciplinary team. It covers technical skills (technical and therapeutic procedures) and non-technical skills, known as Crisis Resource Management. The relationship between stress and performance is theoretically described by the Yerkes-Dodson law as an inverted U-shaped curve. Performance is very low for a low level of stress and increases with an increased level of stress, up to a point, after which performance decreases and becomes severely impaired. The objectives of this randomized trial are to study the effect of stress on performance and the effect of repeated simulation sessions on performance and stress. This study is a single-center, investigator-initiated randomized controlled trial including 48 participants distributed in 12 multidisciplinary teams. Each team is made up of 4 persons: an emergency physician, a resident, a nurse, and an ambulance driver who usually constitute a French Emergency Medical Service team. Six multidisciplinary teams are planning to undergo 9 simulation sessions over 1 year (experimental group), and 6 multidisciplinary teams are planning to undergo 3 simulation sessions over 1 year (control group). Evidence of the existence of stress will be assessed according to 3 criteria: biological, electrophysiological, and psychological stress. The impact of stress on overall team performance, technical procedure and teamwork will be evaluated. Participant self-assessment of the perceived impact of simulations on clinical practice will be collected. Detection of post-traumatic stress disorder will be performed by self-assessment questionnaire on the 7(th) day and after 1 month. We will concomitantly evaluate technical and non-technical performance, and the impact of stress on both. This is the first randomized trial studying repetition of simulation sessions and its impact on both clinical performance and stress, which is explored by objective and subjective assessments. We expect that stress decreases team performance and that repeated simulation will increase it. We expect no variation of stress parameters regardless of the level of performance. ClinicalTrials.gov registration number NCT02424890.

  10. Mining Formative Evaluation Rules Using Web-Based Learning Portfolios for Web-Based Learning Systems

    ERIC Educational Resources Information Center

    Chen, Chih-Ming; Hong, Chin-Ming; Chen, Shyuan-Yi; Liu, Chao-Yu

    2006-01-01

    Learning performance assessment aims to evaluate what knowledge learners have acquired from teaching activities. Objective technical measures of learning performance are difficult to develop, but are extremely important for both teachers and learners. Learning performance assessment using learning portfolios or web server log data is becoming an…

  11. Evaluation of a novel waste heat recovery system for the cement industry using multi-criteria analysis (MCA) approach

    NASA Astrophysics Data System (ADS)

    Han, Yue; Guo, Junshan; Zheng, Wei; Ding, Junqi; Zhu, Lingkai; Che, Yongqiang; Zhang, Yanpeng

    2017-12-01

    Based on a novel waste heat recovery project established in a cement plant, this paper aims to evaluate the performance of the project using multi-criteria analysis (MCA) approach. Economic, environmental, social, and technical perspectives were concerned and analyzed. Different sustainability criteria and indicators related with the project were evaluated through ranking/rating process and pairwise comparison. Results have shown similar outcomes, that ten out of eleven criteria are favorable at a high standard, which reveals the project’s success. Although the project has performed so well in economic, environmental and technical terms, social aspects have some weak points, and measures should be taken to improve social benefit.

  12. Study on evaluation index system of operational performance of municipal wastewater treatment plants in China

    NASA Astrophysics Data System (ADS)

    Xiaoxin, Zhang; Jin, Huang; Ling, Lin; Yan, Li

    2018-05-01

    According to the undeveloped evaluation method for the operational performance of the municipal wastewater treatment plants, this paper analyzes the policies related to sewage treatment industry based on the investigation of the municipal wastewater treatment plants. The applicable evaluation method for the operational performance was proposed from environmental protection performance, resources and energy consumption, technical and economic performance, production management and main equipment, providing a reliable basis for scientific evaluation of the operation as well as improving the operational performance of municipal wastewater treatment plant.

  13. Evaluation of colonoscopy technical skill levels by use of an objective kinematic-based system.

    PubMed

    Obstein, Keith L; Patil, Vaibhav D; Jayender, Jagadeesan; San José Estépar, Raúl; Spofford, Inbar S; Lengyel, Balazs I; Vosburgh, Kirby G; Thompson, Christopher C

    2011-02-01

    Colonoscopy requires training and experience to ensure accuracy and safety. Currently, no objective, validated process exists to determine when an endoscopist has attained technical competence. Kinematics data describing movements of laparoscopic instruments have been used in surgical skill assessment to define expert surgical technique. We have developed a novel system to record kinematics data during colonoscopy and quantitatively assess colonoscopist performance. To use kinematic analysis of colonoscopy to quantitatively assess endoscopic technical performance. Prospective cohort study. Tertiary-care academic medical center. This study involved physicians who perform colonoscopy. Application of a kinematics data collection system to colonoscopy evaluation. Kinematics data, validated task load assessment instrument, and technical difficulty visual analog scale. All 13 participants completed the colonoscopy to the terminal ileum on the standard colon model. Attending physicians reached the terminal ileum quicker than fellows (median time, 150.19 seconds vs 299.86 seconds; p<.01) with reduced path lengths for all 4 sensors, decreased flex (1.75 m vs 3.14 m; P=.03), smaller tip angulation, reduced absolute roll, and lower curvature of the endoscope. With performance of attending physicians serving as the expert reference standard, the mean kinematic score increased by 19.89 for each decrease in postgraduate year (P<.01). Overall, fellows experienced greater mental, physical, and temporal demand than did attending physicians. Small cohort size. Kinematic data and score calculation appear useful in the evaluation of colonoscopy technical skill levels. The kinematic score appears to consistently vary by year of training. Because this assessment is nonsubjective, it may be an improvement over current methods for determination of competence. Ongoing studies are establishing benchmarks and characteristic profiles of skill groups based on kinematics data. Copyright © 2011 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  14. Preoperative short hookwire placement for small pulmonary lesions: evaluation of technical success and risk factors for initial placement failure.

    PubMed

    Iguchi, Toshihiro; Hiraki, Takao; Matsui, Yusuke; Fujiwara, Hiroyasu; Masaoka, Yoshihisa; Tanaka, Takashi; Sato, Takuya; Gobara, Hideo; Toyooka, Shinichi; Kanazawa, Susumu

    2018-05-01

    To retrospectively evaluate the technical success of computed tomography fluoroscopy-guided short hookwire placement before video-assisted thoracoscopic surgery and to identify the risk factors for initial placement failure. In total, 401 short hookwire placements for 401 lesions (mean diameter 9.3 mm) were reviewed. Technical success was defined as correct positioning of the hookwire. Possible risk factors for initial placement failure (i.e., requirement for placement of an additional hookwire or to abort the attempt) were evaluated using logistic regression analysis for all procedures, and for procedures performed via the conventional route separately. Of the 401 initial placements, 383 were successful and 18 failed. Short hookwires were finally placed for 399 of 401 lesions (99.5%). Univariate logistic regression analyses revealed that in all 401 procedures only the transfissural approach was a significant independent predictor of initial placement failure (odds ratio, OR, 15.326; 95% confidence interval, CI, 5.429-43.267; p < 0.001) and for the 374 procedures performed via the conventional route only lesion size was a significant independent predictor of failure (OR 0.793, 95% CI 0.631-0.996; p = 0.046). The technical success of preoperative short hookwire placement was extremely high. The transfissural approach was a predictor initial placement failure for all procedures and small lesion size was a predictor of initial placement failure for procedures performed via the conventional route. • Technical success of preoperative short hookwire placement was extremely high. • The transfissural approach was a significant independent predictor of initial placement failure for all procedures. • Small lesion size was a significant independent predictor of initial placement failure for procedures performed via the conventional route.

  15. A procedural skills OSCE: assessing technical and non-technical skills of internal medicine residents.

    PubMed

    Pugh, Debra; Hamstra, Stanley J; Wood, Timothy J; Humphrey-Murto, Susan; Touchie, Claire; Yudkowsky, Rachel; Bordage, Georges

    2015-03-01

    Internists are required to perform a number of procedures that require mastery of technical and non-technical skills, however, formal assessment of these skills is often lacking. The purpose of this study was to develop, implement, and gather validity evidence for a procedural skills objective structured clinical examination (PS-OSCE) for internal medicine (IM) residents to assess their technical and non-technical skills when performing procedures. Thirty-five first to third-year IM residents participated in a 5-station PS-OSCE, which combined partial task models, standardized patients, and allied health professionals. Formal blueprinting was performed and content experts were used to develop the cases and rating instruments. Examiners underwent a frame-of-reference training session to prepare them for their rater role. Scores were compared by levels of training, experience, and to evaluation data from a non-procedural OSCE (IM-OSCE). Reliability was calculated using Generalizability analyses. Reliabilities for the technical and non-technical scores were 0.68 and 0.76, respectively. Third-year residents scored significantly higher than first-year residents on the technical (73.5 vs. 62.2%) and non-technical (83.2 vs. 75.1%) components of the PS-OSCE (p < 0.05). Residents who had performed the procedures more frequently scored higher on three of the five stations (p < 0.05). There was a moderate disattenuated correlation (r = 0.77) between the IM-OSCE and the technical component of the PS-OSCE scores. The PS-OSCE is a feasible method for assessing multiple competencies related to performing procedures and this study provides validity evidence to support its use as an in-training examination.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adhikari, B.; Pellegrino, J.; Stickel, J.

    We are currently evaluating the feasibility of performing continuous enzymatic hydrolysis of lignocellulosic biomass to product sugars using a membrane-assisted reaction/separation process. The overarching technical goals are to continuously remove the sugars—this lowers product feedback inhibition—retain and recycle active enzyme, and continuously recover the co-product of lignin. Experimental d d d currently evaluating the feasibility of performing continuous enzymatic hydrolysis of lignocellulosic biomass to product sugars using a membrane-assisted reaction/separation process. The overarching technical goals are to continuously remove the sugars -- this lowers product feedback inhibition --retain and recycle active enzyme, and continuously recover the co-product of lignin.

  17. 48 CFR 919.7013 - Reports.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... BUSINESS PROGRAMS The Department of Energy Mentor-Protege Program 919.7013 Reports. (a) Prior to performing an evaluation of a Mentor's performance under its Mentor-Protege Agreement for use in award fee evaluations, the Mentor-Protege Program Manager must consult with the cognizant DOE technical program manager...

  18. Evaluating Technical Efficiency of Nursing Care Using Data Envelopment Analysis and Multilevel Modeling.

    PubMed

    Min, Ari; Park, Chang Gi; Scott, Linda D

    2016-05-23

    Data envelopment analysis (DEA) is an advantageous non-parametric technique for evaluating relative efficiency of performance. This article describes use of DEA to estimate technical efficiency of nursing care and demonstrates the benefits of using multilevel modeling to identify characteristics of efficient facilities in the second stage of analysis. Data were drawn from LTCFocUS.org, a secondary database including nursing home data from the Online Survey Certification and Reporting System and Minimum Data Set. In this example, 2,267 non-hospital-based nursing homes were evaluated. Use of DEA with nurse staffing levels as inputs and quality of care as outputs allowed estimation of the relative technical efficiency of nursing care in these facilities. In the second stage, multilevel modeling was applied to identify organizational factors contributing to technical efficiency. Use of multilevel modeling avoided biased estimation of findings for nested data and provided comprehensive information on differences in technical efficiency among counties and states. © The Author(s) 2016.

  19. The Accreditation Experience of Clinical Laboratories and Blood Banks in Mexico

    PubMed Central

    2015-01-01

    The accreditation of clinical laboratories and blood banks based on ISO 15189 is now being consolidated in Mexico, and is coordinated by the Mexican accreditation entity innovative strategies, A.C. (ema) and supported by the activities of the committee of clinical laboratories and blood banks. The active participation in working groups formed by the technical committee of clinical laboratories and blood banks in specific areas, has contributed to the formulation of technical documents and criteria of evaluation that strengthen the current accreditation scheme. The national registry of evaluation (PNE) consists of technical experts and evaluators from different disciplines of clinical laboratory; the evaluators actively participate in accreditation assessment, with an ultimate goal to receive training and feedback for continuous improvement of its own performance. PMID:27683498

  20. Technical and physical determinants of soccer match-play performance in elite youth soccer players.

    PubMed

    Rowat, Owain; Fenner, Jonathan; Unnithan, Viswanath

    2017-04-01

    The aim of this study was to evaluate whether physical performance characteristics could be a better predictor than technical skills in determining the technical level of county soccer players in a match situation. With institutional ethics approval, 25 male youth soccer players aged 16-18.5 years from a professional soccer academy in South East Asia were selected and height and body mass were recorded. Players were tested for sexual maturity (pubertal development scale [PDS] self-assessment), aerobic capacity (yo-yo intermittent recovery test level 1 [YYIR1]), repeated sprint ability (7 x 35 m sprints) acceleration (15 m sprint) and four soccer skills tests (dribble with pass, dribbling speed, passing and shooting accuracy). Players' technical ability during match play was assessed in small-sided games of soccer (5 v 5) using a novel game technical scoring chart (scoring chart completed by coaches to assess technical performance in a match situation) developed from criteria (e.g., first touch, dribbling and two footedness) used by youth soccer coaches for talent identification. A Spearman's rank correlation showed the YYIR1 test and 15 m sprint test were limited in predicting technical match performance (r=0.03, P=0.88, r=-0.23, P=0.32 respectively). A Pearson product moment correlation showed that the repeated sprint test was also limited in predicting technical match performance (r=-0.34, P=0.14). A dribbling skill with a pass was found to be the best determinant of a player's technical ability in a match (r=-0.57, P=0.00). Talent identification and selection programs in Asian youth soccer should include a dribbling skill performed with a pass.

  1. Standardized Technical Data Survey (STDS) for Aerial Refueling

    DTIC Science & Technology

    2016-09-06

    the KC-135 and the German Tornado . The tanker/receiver combination was certified by a technical evaluation of the performance interface survey, face...another. That document was first used in assessing the compatibility of the KC-135 and the German Tornado . The survey questions, when accurately answered

  2. Performance evaluation approach for the supercritical helium cold circulators of ITER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vaghela, H.; Sarkar, B.; Bhattacharya, R.

    2014-01-29

    The ITER project design foresees Supercritical Helium (SHe) forced flow cooling for the main cryogenic components, namely, the superconducting (SC) magnets and cryopumps (CP). Therefore, cold circulators have been selected to provide the required SHe mass flow rate to cope with specific operating conditions and technical requirements. Considering the availability impacts of such machines, it has been decided to perform evaluation tests of the cold circulators at operating conditions prior to the series production in order to minimize the project technical risks. A proposal has been conceptualized, evaluated and simulated to perform representative tests of the full scale SHe coldmore » circulators. The objectives of the performance tests include the validation of normal operating condition, transient and off-design operating modes as well as the efficiency measurement. A suitable process and instrumentation diagram of the test valve box (TVB) has been developed to implement the tests at the required thermodynamic conditions. The conceptual engineering design of the TVB has been developed along with the required thermal analysis for the normal operating conditions to support the performance evaluation of the SHe cold circulator.« less

  3. Radiographic technical quality of root canal treatment performed by a new rotary single-file system.

    PubMed

    Colombo, Marco; Bassi, Cristina; Beltrami, Riccardo; Vigorelli, Paolo; Spinelli, Antonio; Cavada, Andrea; Dagna, Alberto; Chiesa, Marco; Poggio, Claudio

    2017-01-01

    The aim of the present study was to evaluate radiographically the technical quality of root canal filling performed by postgraduate students with a new single-file Nickel-Titanium System (F6 Skytaper Komet) in clinical practice. Records of 74 patients who had received endodontic treatment by postgraduate students at the School of Dentistry, Faculty of Medicine, University of Pavia in the period between September 2015 and April 2016 were collected and examined: the final sample consisted 114 teeth and 204 root canals. The quality of endodontic treatment was evaluated by examining the length of the filling in relation to the radiographic apex, the density of the obturation according to the presence of voids and the taper of root canal filling. Chi-squared analysis was used to determine statistically significant differences between the technical quality of root fillings according to tooth's type, position and curvature. The results showed that 75,49%, 82,84% and 90,69% of root filled canals had adequate length, density and taper respectively. Overall, the technical quality of root canal fillings performed by postgraduates students was acceptable in 60,78% of the cases.

  4. Learning curves for transapical transcatheter aortic valve replacement in the PARTNER-I trial: Technical performance, success, and safety.

    PubMed

    Suri, Rakesh M; Minha, Sa'ar; Alli, Oluseun; Waksman, Ron; Rihal, Charanjit S; Satler, Lowell P; Greason, Kevin L; Torguson, Rebecca; Pichard, Augusto D; Mack, Michael; Svensson, Lars G; Rajeswaran, Jeevanantham; Lowry, Ashley M; Ehrlinger, John; Mick, Stephanie L; Tuzcu, E Murat; Thourani, Vinod H; Makkar, Raj; Holmes, David; Leon, Martin B; Blackstone, Eugene H

    2016-09-01

    Introduction of hybrid techniques, such as transapical transcatheter aortic valve replacement (TA-TAVR), requires skills that a heart team must master to achieve technical efficiency: the technical performance learning curve. To date, the learning curve for TA-TAVR remains unknown. We therefore evaluated the rate at which technical performance improved, assessed change in occurrence of adverse events in relation to technical performance, and determined whether adverse events after TA-TAVR were linked to acquiring technical performance efficiency (the learning curve). From April 2007 to February 2012, 1100 patients, average age 85.0 ± 6.4 years, underwent TA-TAVR in the PARTNER-I trial. Learning curves were defined by institution-specific patient sequence number using nonlinear mixed modeling. Mean procedure time decreased from 131 to 116 minutes within 30 cases (P = .06) and device success increased to 90% by case 45 (P = .0007). Within 30 days, 354 patients experienced a major adverse event (stroke in 29, death in 96), with possibly decreased complications over time (P ∼ .08). Although longer procedure time was associated with more adverse events (P < .0001), these events were associated with change in patient risk profile, not the technical performance learning curve (P = .8). The learning curve for TA-TAVR was 30 to 45 procedures performed, and technical efficiency was achieved without compromising patient safety. Although fewer patients are now undergoing TAVR via nontransfemoral access, understanding TA-TAVR learning curves and their relationship with outcomes is important as the field moves toward next-generation devices, such as those to replace the mitral valve, delivered via the left ventricular apex. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  5. 48 CFR 1552.215-71 - Evaluation factors for award.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... for technical acceptability evaluation: (c) Factors for past performance evaluation (optional): (End... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Evaluation factors for award. 1552.215-71 Section 1552.215-71 Federal Acquisition Regulations System ENVIRONMENTAL PROTECTION...

  6. Outdoor Leadership Evaluation: Nature and Scope of the Problem.

    ERIC Educational Resources Information Center

    James, Leroy M.

    Beyond the ability to exhibit good judgment and common sense while performing duties as a leader under stress and pressure, an outdoor adventure program leader should possess technical skills, human relations skills, and philosophical understanding of outdoor programming. Technical skills include knowledge of initiatives/ropes course activities,…

  7. The 1991 International Conference on Aging Aircraft and Structural Airworthiness

    NASA Technical Reports Server (NTRS)

    Harris, Charles E. (Editor)

    1992-01-01

    Technical sessions of the conference included structural performance, nondestructive evaluation, maintenance and repair, international activities, and commuter airlines. Each session was organized to provide a well-rounded view of the subject from the industry, regulatory, and research perspective. Thirty-four presentations were given by the international technical community.

  8. Effects and effectiveness of dynamic arm supports: a technical review.

    PubMed

    van der Heide, Loek A; Gelderblom, Gert Jan; de Witte, Luc P

    2015-01-01

    Numerous dynamic arm supports have been developed in recent decades to increase independence in the performance of activities of daily living. Much effort and money have been spent on their development and prescription, yet insight into their effects and effectiveness is lacking. This article is a systematic review of evaluations of dynamic arm supports. The 8 technical evaluations, 12 usability evaluations, and 27 outcome studies together make 47 evaluations. Technical evaluations were often used as input for new developments and directed at balancing quality, forces and torques, and range of motion of prototypes. Usability studies were mostly single-measure designs that had varying results as to whether devices were usable for potential users. An increased ability to perform activities of daily living and user satisfaction were reported in outcome studies. However, the use of dynamic arm supports in the home situation was reported to be low. Gaining insight into why devices are not used when their developers believe them to be effective seems crucial for every new dynamic arm support developed. The methodological quality of the outcome studies was often low, so it is important that this is improved in the future.

  9. TECHNOLOGY EVALUATION REPORT, HYDROTECHNICS IN SITU FLOW SENSOR

    EPA Science Inventory

    The U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation (SITE) Program evaluated performance of HydroTechnics, Inc. flow sensors in measuring the three-dimensional flow pattern created by operation of the Wasatch Environmental, Inc. (WEI) ground...

  10. Laparoscopic skills suffer on the first shift of sequential night shifts: program directors beware and residents prepare.

    PubMed

    Leff, Daniel R; Aggarwal, Rajesh; Rana, Mariam; Nakhjavani, Batool; Purkayastha, Sanjay; Khullar, Vik; Darzi, Ara W

    2008-03-01

    Research evaluating fatigue-induced skills decline has focused on acute sleep deprivation rather than the effects of circadian desynchronization associated with multiple shifts. As a result, the number of consecutive night shifts that residents can safely be on duty without detrimental effects to their technical skills remains unknown. A prospective observational cohort study was conducted to assess the impact of 7 successive night shifts on the technical surgical performance of junior residents. The interventional strategy included training 21 residents from surgery and allied disciplines on a virtual reality surgical simulator, towards the achievement of preset benchmark scores, followed by 294 technical skills assessments conducted over 1764 manpower night shift hours. Primary outcomes comprised serial technical skills assessments on 2 tasks of a virtual reality surgical simulator. Secondary outcomes included assessments of introspective fatigue, duration of sleep, and prospective recordings of activity (number of "calls" received, steps walked, and patients evaluated). Maximal deterioration in performance was observed following the first night shift. Residents took significantly longer to complete the first (P = 0.002) and second tasks (P = 0.005) compared with baseline. They also committed significantly greater numbers of errors (P = 0.025) on the first task assessed. Improved performance was observed across subsequent shifts towards baseline levels. Newly acquired technical surgical skills deteriorate maximally after the first night shift, emphasizing the importance of adequate preparation for night rotas. Performance improvements across successive shifts may be due to ongoing learning or adaptation to chronic fatigue. Further research should focus on assessments of both technical procedural skills and cognitive abilities to determine the rotas that best minimize errors and maximize patient safety.

  11. Determining the Effectiveness and Evaluating the Implementation Process of a Quality/Performance Circles System Model to Assist in Institutional Decision Making and Problem Solving at Lakeshore Technical Institute.

    ERIC Educational Resources Information Center

    Ladwig, Dennis J.

    During the 1982-83 school year, a quality/performance circles system model was implemented at Lakeshore Technical Institute (LTI) to promote greater participation by staff in decision making and problem solving. All management staff at the college (N=45) were invited to participate in the process, and 39 volunteered. Non-management staff (N=240)…

  12. Solar energy system economic evaluation: Fern Tunkhannock, Tunkhannock, Pennsylvania

    NASA Astrophysics Data System (ADS)

    1980-09-01

    The economic performance of an Operational Test Site (OTS) is described. The long term economic performance of the system at its installation site and extrapolation to four additional selected locations to demonstrate the viability of the design over a broad range of environmental and economic conditions is reported. Topics discussed are: system description, study approach, economic analysis and system optimization, and technical and economical results of analysis. Data for the economic analysis are generated through evaluation of the OTS. The simulation is based on the technical results of the seasonal report simulation. In addition localized and standard economic parameters are used for economic analysis.

  13. Solar energy system economic evaluation: Fern Tunkhannock, Tunkhannock, Pennsylvania

    NASA Technical Reports Server (NTRS)

    1980-01-01

    The economic performance of an Operational Test Site (OTS) is described. The long term economic performance of the system at its installation site and extrapolation to four additional selected locations to demonstrate the viability of the design over a broad range of environmental and economic conditions is reported. Topics discussed are: system description, study approach, economic analysis and system optimization, and technical and economical results of analysis. Data for the economic analysis are generated through evaluation of the OTS. The simulation is based on the technical results of the seasonal report simulation. In addition localized and standard economic parameters are used for economic analysis.

  14. Simulation-based team training improved the self-assessed ability of physicians, nurses and midwives to perform neonatal resuscitation.

    PubMed

    Malmström, B; Nohlert, E; Ewald, U; Widarsson, M

    2017-08-01

    The use of simulation-based team training in neonatal resuscitation has increased in Sweden during the last decade, but no formal evaluation of this training method has been performed. This study evaluated the effect of simulation-based team training on the self-assessed ability of personnel to perform neonatal resuscitation. We evaluated a full-day simulation-based team training course in neonatal resuscitation, by administering a questionnaire to 110 physicians, nurses and midwives before and after the training period. The questionnaire focused on four important domains: communication, leadership, confidence and technical skills. The study was carried out in Sweden from 2005 to 2007. The response rate was 84%. Improvements in the participants' self-assessed ability to perform neonatal resuscitation were seen in all four domains after training (p < 0.001). Professionally inexperienced personnel showed a significant improvement in the technical skills domain compared to experienced personnel (p = 0.001). No differences were seen between professions or time since training in any of the four domains. Personnel with less previous experience with neonatal resuscitation showed improved confidence (p = 0.007) and technical skills (p = 0.003). A full-day course on simulation-based team training with video-supported debriefing improved the participants' self-assessed ability to perform neonatal resuscitation. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  15. Temporal Changes in Technical and Physical Performances During a Small-Sided Game in Elite Youth Soccer Players

    PubMed Central

    Moreira, Alexandre; Saldanha Aoki, Marcelo; Carling, Chris; Alan Rodrigues Lopes, Rafael; Felipe Schultz de Arruda, Ademir; Lima, Marcelo; Cesar Correa, Umberto; Bradley, Paul S

    2016-01-01

    Background There have been claims that small-sided games (SSG) may generate an appropriate environment to develop youth players’ technical performance associated to game-related problem solving. However, the temporal change in technical performance parameters of youth players during SSG is still unknown. Objectives The aim of this study was to examine temporal changes in technical and physical performances during a small-sided game (SSG) in elite soccer players. Methods Sixty elite youth players (age 14.8 ± 0.2 yr; stature 177 ± 5 cm; body mass 66.2 ± 4.7 kg) completed a 5 v 5 SSG using two repetitions of 8 minutes interspersed by 3 minutes of passive recovery. To evaluate temporal changes in performance, the data were analysed across 4 minutes quarters. Physical performance parameters included the total distance covered (TDC), the frequency of sprints (>18 km•h-1), accelerations and decelerations (> 2.0 m•s-2 and - 2.0 m•s-2), metabolic power (W•kg-1), training impulse (TRIMP), TDC: TRIMP, number of impacts, and body load. Technical performance parameters included goal attempts, total number of tackles, tackles and interceptions, total number of passes, and passes effectiveness. Results All physical performance parameters decreased from the first to the last quarter with notable declines in TDC, metabolic power and the frequency of sprints, accelerations and decelerations (P < 0.05; moderate to very large ES: 1.08 - 3.30). However, technical performance parameters did not vary across quarters (P > 0.05; trivial ES for 1st v 4th quarters: 0.15 - 0.33). Conclusions The data demonstrate that technical performance is maintained despite substantial declines in physical performance during a SSG in elite youth players. This finding may have implications for designing SSG’s for elite youth players to ensure physical, technical and tactical capabilities are optimized. Modifications in player number, pitch dimensions, rules, coach encouragement, for instance, should be included taking into account the main aim of a given session and then focused on overloading physical or technical elements. PMID:28144411

  16. Temporal Changes in Technical and Physical Performances During a Small-Sided Game in Elite Youth Soccer Players.

    PubMed

    Moreira, Alexandre; Saldanha Aoki, Marcelo; Carling, Chris; Alan Rodrigues Lopes, Rafael; Felipe Schultz de Arruda, Ademir; Lima, Marcelo; Cesar Correa, Umberto; Bradley, Paul S

    2016-12-01

    There have been claims that small-sided games (SSG) may generate an appropriate environment to develop youth players' technical performance associated to game-related problem solving. However, the temporal change in technical performance parameters of youth players during SSG is still unknown. The aim of this study was to examine temporal changes in technical and physical performances during a small-sided game (SSG) in elite soccer players. Sixty elite youth players (age 14.8 ± 0.2 yr; stature 177 ± 5 cm; body mass 66.2 ± 4.7 kg) completed a 5 v 5 SSG using two repetitions of 8 minutes interspersed by 3 minutes of passive recovery. To evaluate temporal changes in performance, the data were analysed across 4 minutes quarters. Physical performance parameters included the total distance covered (TDC), the frequency of sprints (>18 km•h -1 ), accelerations and decelerations (> 2.0 m•s -2 and - 2.0 m•s -2 ), metabolic power (W•kg -1 ), training impulse (TRIMP), TDC: TRIMP, number of impacts, and body load. Technical performance parameters included goal attempts, total number of tackles, tackles and interceptions, total number of passes, and passes effectiveness. All physical performance parameters decreased from the first to the last quarter with notable declines in TDC, metabolic power and the frequency of sprints, accelerations and decelerations (P < 0.05; moderate to very large ES: 1.08 - 3.30). However, technical performance parameters did not vary across quarters (P > 0.05; trivial ES for 1st v 4th quarters: 0.15 - 0.33). The data demonstrate that technical performance is maintained despite substantial declines in physical performance during a SSG in elite youth players. This finding may have implications for designing SSG's for elite youth players to ensure physical, technical and tactical capabilities are optimized. Modifications in player number, pitch dimensions, rules, coach encouragement, for instance, should be included taking into account the main aim of a given session and then focused on overloading physical or technical elements.

  17. A novel approach to assessing technical competence of colorectal surgery residents: the development and evaluation of the Colorectal Objective Structured Assessment of Technical Skill (COSATS).

    PubMed

    de Montbrun, Sandra L; Roberts, Patricia L; Lowry, Ann C; Ault, Glenn T; Burnstein, Marcus J; Cataldo, Peter A; Dozois, Eric J; Dunn, Gary D; Fleshman, James; Isenberg, Gerald A; Mahmoud, Najjia N; Reznick, Richard K; Satterthwaite, Lisa; Schoetz, David; Trudel, Judith L; Weiss, Eric G; Wexner, Steven D; MacRae, Helen

    2013-12-01

    To develop and evaluate an objective method of technical skills assessment for graduating subspecialists in colorectal (CR) surgery-the Colorectal Objective Structured Assessment of Technical Skill (COSATS). It may be reasonable for the public to assume that surgeons certified as competent have had their technical skills assessed. However, technical skill, despite being the hallmark of a surgeon, is not directly assessed at the time of certification by surgical boards. A procedure-based, multistation technical skills examination was developed to reflect a sample of the range of skills necessary for CR surgical practice. These consisted of bench, virtual reality, and cadaveric models. Reliability and construct validity were evaluated by comparing 10 graduating CR residents with 10 graduating general surgery (GS) residents from across North America. Expert CR surgeons, blinded to level of training, evaluated performance using a task-specific checklist and a global rating scale. The mean global rating score was used as the overall examination score and a passing score was set at "borderline competent for CR practice." The global rating scale demonstrated acceptable interstation reliability (0.69) for a homogeneous group of examinees. Both the overall checklist and global rating scores effectively discriminated between CR and GS residents (P < 0.01), with 27% of the variance attributed to level of training. Nine CR residents but only 3 GS residents were deemed competent. The Colorectal Objective Structured Assessment of Technical Skill effectively discriminated between CR and GS residents. With further validation, the Colorectal Objective Structured Assessment of Technical Skill could be incorporated into the colorectal board examination where it would be the first attempt of a surgical specialty to formally assess technical skill at the time of certification.

  18. SITE PROGRAM EVALUATION OF THE SONOTECH PULSE COMBUSTION BURNER TECHNOLOGY - TECHNICAL RESULTS

    EPA Science Inventory

    A series of demonstration tests was performed at the Environmental Protection Agency's (EPA's) Incineration Research Facility (IRF) under the Superfund Innovative Technology Evaluation (SITE) program. These tests, twelve in all, evaluated a pulse combustion burner technology dev...

  19. Performance and economics of advanced energy conversion systems for coal and coal-derived fuels

    NASA Technical Reports Server (NTRS)

    Corman, J. C.; Fox, G. R.

    1978-01-01

    The desire to establish an efficient Energy Conversion System to utilize the fossil fuel of the future - coal - has produced many candidate systems. A comparative technical/economic evaluation was performed on the seven most attractive advanced energy conversion systems. The evaluation maintains a cycle-to-cycle consistency in both performance and economic projections. The technical information base can be employed to make program decisions regarding the most attractive concept. A reference steam power plant was analyzed to the same detail and, under the same ground rules, was used as a comparison base. The power plants were all designed to utilize coal or coal-derived fuels and were targeted to meet an environmental standard. The systems evaluated were two advanced steam systems, a potassium topping cycle, a closed cycle helium system, two open cycle gas turbine combined cycles, and an open cycle MHD system.

  20. [The study of establishment of the " Chinese provincial Blindness prevention technical guidance group performance evaluation system"].

    PubMed

    Lu, L N; He, X G; Zhu, J F; Xu, X; Zhang, R; Hu, X; Zou, H D

    2016-11-11

    Objective: To establish an assessment system, including indexes and scoring methods, that can be used for performance evaluation of the provincial blindness prevention technical guidance group properly and effectively . Methods: The indexes and scoring methods were set based on the core content of The " National Plan of Prevention and Treatment of Blindness (2012-2015)" , the specific requirement and target of the World Health Organization (WHO) "For the General Eye Health: Global plan of Action (2014-2019)" , and the current situation of the China's provinces and autonomous regions. These indexes should be of effectiveness, feasibility, comparability, guidance and advancing. Formed by a literature review of candidate indicators, the framework of the system is built by qualitative assessment. With the Delphi method, the system was further revised and improved. Empirical pilot study was then used to prove the feasibility, followed by the final qualitative analysis that establish the " Chinese provincial Blindness prevention technical guidance group performance evaluation system" . Results: Through the literature review and qualitative assessment, a six dimensional system framework was built, including 6 first-level indicators, 16 second-level indicators, and 29 third-level indicators through Delphi method evaluation. With the variation coefficient method, the coeffiences of the first-level index weight were calculated as: Organization and management 0.15, Development and implementation of blindness prevention plans 0.15, Implementation of blindness prevention projects 0.14, Training 0.17, Health education 0.18, and Cooperation and exchanges 0.21. The specific scoring method for this system is confirmed as: data and files check, field interview, and record interview, sampling investigation. Empirical pilot study was conducted in the Jilin, Guizhou and Gansu provinces, and the self-assessment results from local experts were consistent with the scores from the systems. Conclusion: This system established is appropriate at current time, and it can effectively evaluate the performance of the Chinese provincial Blindness prevention technical guidance group. (Chin J Ophthalmol, 2016, 52:814-824) .

  1. Evaluation of ERDA-sponsored coal feed system development

    NASA Technical Reports Server (NTRS)

    Phen, R. L.; Luckow, W. K.; Mattson, L.; Otth, D.; Tsou, P.

    1977-01-01

    Coal feeders were evaluated based upon criteria such as technical feasibility, performance (i.e. ability to meet process requirements), projected life cycle costs, and projected development cost. An initial set of feeders was selected based on the feeders' cost savings potential compared with baseline lockhopper systems. Additional feeders were considered for selection based on: (1) increasing the probability of successful feeder development; (2) application to specific processes; and (3) technical merit. A coal feeder development program is outlined.

  2. Effects of a Velocity-Vector Based Command Augmentation System and Synthetic Vision System Terrain Portrayal and Guidance Symbology Concepts on Single-Pilot Performance

    NASA Technical Reports Server (NTRS)

    Liu, Dahai; Goodrich, Kenneth H.; Peak, Bob

    2010-01-01

    This study investigated the effects of synthetic vision system (SVS) concepts and advanced flight controls on the performance of pilots flying a light, single-engine general aviation airplane. We evaluated the effects and interactions of two levels of terrain portrayal, guidance symbology, and flight control response type on pilot performance during the conduct of a relatively complex instrument approach procedure. The terrain and guidance presentations were evaluated as elements of an integrated primary flight display system. The approach procedure used in the study included a steeply descending, curved segment as might be encountered in emerging, required navigation performance (RNP) based procedures. Pilot performance measures consisted of flight technical performance, perceived workload, perceived situational awareness and subjective preference. The results revealed that an elevation based generic terrain portrayal significantly improved perceived situation awareness without adversely affecting flight technical performance or workload. Other factors (pilot instrument rating, control response type, and guidance symbology) were not found to significantly affect the performance measures.

  3. Multidisciplinary crisis simulations: the way forward for training surgical teams.

    PubMed

    Undre, Shabnam; Koutantji, Maria; Sevdalis, Nick; Gautama, Sanjay; Selvapatt, Nowlan; Williams, Samantha; Sains, Parvinderpal; McCulloch, Peter; Darzi, Ara; Vincent, Charles

    2007-09-01

    High-reliability organizations have stressed the importance of non-technical skills for safety and of regularly providing such training to their teams. Recently safety skills training has been applied in the practice of medicine. In this study, we developed and piloted a module using multidisciplinary crisis scenarios in a simulated operating theatre to train entire surgical teams. Twenty teams participated (n = 80); each consisted of a trainee surgeon, anesthetist, operating department practitioner (ODP), and scrub nurse. Crisis scenarios such as difficult intubation, hemorrhage, or cardiac arrest were simulated. Technical and non-technical skills (leadership, communication, team skills, decision making, and vigilance), were assessed by clinical experts and by two psychologists using relevant technical and human factors rating scales. Participants received technical and non-technical feedback, and the whole team received feedback on teamwork. Trainees assessed the training favorably. For technical skills there were no differences between surgical trainees' assessment scores and the assessment scores of the trainers. However, nurses overrated their technical skill. Regarding non-technical skills, leadership and decision making were scored lower than the other three non-technical skills (communication, team skills, and vigilance). Surgeons scored lower than nurses on communication and teamwork skills. Surgeons and anesthetists scored lower than nurses on leadership. Multidisciplinary simulation-based team training is feasible and well received by surgical teams. Non-technical skills can be assessed alongside technical skills, and differences in performance indicate where there is a need for further training. Future work should focus on developing team performance measures for training and on the development and evaluation of systematic training for technical and non-technical skills to enhance team performance and safety in surgery.

  4. ICU staffing: identification and survey of staff involved in providing technical support services to Australian and New Zealand intensive care units.

    PubMed

    Carter, B G; Kiraly, N; Hochmann, M; Stephens, R; Osborne, A

    2007-04-01

    We conducted a survey of all (200) Australian and New Zealand intensive care units to determine the presence and nature of staff employed in a technical support role. Specifically, we attempted to identify staff who are formally employed in a role where they are directly responsible for the equipment used in intensive care. Of 130 returned surveys, 80 units (62%) reported not having any personnel in this role. In these units technical tasks were most commonly performed by registered nurses (79%) but were also performed by a variety of other personnel. Fifty units (38%), consisting of approximately 105 individuals providing a total of 84.3 EFTs and most commonly in public (84%) or metropolitan (70%) hospitals or level 3 (64%) intensive care units, did have one or more staff acting in a formal technical support role. The most common groups filling the technical support role were nurses (42%), technicians (24%), biomedical engineers (10%) and technologists (6%). The most common duties performed were equipment troubleshooting (92%), training (80%), equipment evaluation (80%), ordering supplies (77%), consumable evaluation (75%), equipment cleaning (73%), delivery of supplies (70%), handling product recalls (65%), equipment maintenance (65%) and sitting on hospital committees (52%). This is the first attempt to identify and understand the technical support role in Australian and New Zealand intensive care units. Numerous issues remain and future work will hopefully add to our findings, with the possibility of formal recognition of the role, training and/or accreditation and its extension into other hospital departments.

  5. IDEA Technical Report No. 2. Description of Data Base, 1976-77.

    ERIC Educational Resources Information Center

    Cashin, William E.; Slawson, Hugh M.

    The data and computational procedures used by the IDEA system at Kansas State University (during the 1976-77 academic year) to interpret ratings of teacher performance are described in this technical report. The computations for each of the seven parts (evaluation, course description, students' self ratings, methods, additional questions,…

  6. IDEA Technical Report No. 3. Description of Data Base, 1977-78.

    ERIC Educational Resources Information Center

    Cashin, William E.; Slawson, Hugh M.

    The data and computational procedures used by the IDEA System during the 1977-78 academic year at Kansas State University to interpret ratings of teacher performance are described in this technical report. The computations for each of the seven parts (evaluation, course description, students' self-ratings, methods, additional questions, diagnostic…

  7. Technical Performance as a Predictor of Clinical Outcomes in Laparoscopic Gastric Cancer Surgery.

    PubMed

    Fecso, Andras B; Bhatti, Junaid A; Stotland, Peter K; Quereshy, Fayez A; Grantcharov, Teodor P

    2018-03-23

    The purpose of this study was to evaluate the relationship between technical performance and patient outcomes in laparoscopic gastric cancer surgery. Laparoscopic gastrectomy for cancer is an advanced procedure with high rate of postoperative morbidity and mortality. Many variables including patient, disease, and perioperative management factors have been shown to impact postoperative outcomes; however, the role of surgical performance is insufficiently investigated. A retrospective review was performed for all patients who had undergone laparoscopic gastrectomy for cancer at 3 teaching institutions between 2009 and 2015. Patients with available, unedited video-recording of their procedure were included in the study. Video files were rated for technical performance, using Objective Structured Assessments of Technical Skills (OSATS) and Generic Error Rating Tool instruments. The main outcome variable was major short-term complications. The effect of technical performance on patient outcomes was assessed using logistic regression analysis with backward selection strategy. Sixty-one patients with available video recordings were included in the study. The overall complication rate was 29.5%. The mean Charlson comorbidity index, type of procedure, and the global OSATS score were included in the final predictive model. Lower performance score (OSATS ≤29) remained an independent predictor for major short-term outcomes (odds ratio 6.49), while adjusting for comorbidities and type of procedure. Intraoperative technical performance predicts major short-term outcomes in laparoscopic gastrectomy for cancer. Ongoing assessment and enhancement of surgical skills using modern, evidence-based strategies might improve short-term patient outcomes. Future work should focus on developing and studying the effectiveness of such interventions in laparoscopic gastric cancer surgery.

  8. Kentucky commercial vehicle safety applications evaluation : technical report.

    DOT National Transportation Integrated Search

    2008-01-31

    An advanced-technology Integrated Safety and Security Enforcement System (ISSES), now deployed at three commercial vehicle inspection sites along interstate highways in Kentucky, was evaluated from the point of view of system performance, potential e...

  9. Implementing and Evaluating a National Certification Technical Skills Examination: The Colorectal Objective Structured Assessment of Technical Skill.

    PubMed

    de Montbrun, Sandra; Roberts, Patricia L; Satterthwaite, Lisa; MacRae, Helen

    2016-07-01

    To implement the Colorectal Objective Structured Assessment of Technical skill (COSATS) into American Board of Colon and Rectal Surgery (ABCRS) certification and build evidence of validity for the interpretation of the scores of this high stakes assessment tool. Currently, technical skill assessment is not a formal component of board certification. With the technical demands of surgical specialties, documenting competence in technical skill at the time of certification with a valid tool is ideal. In September 2014, the COSATS was a mandatory component of ABCRS certification. Seventy candidates took the examination, with their performance evaluated by expert colorectal surgeons using a task-specific checklist, global rating scale, and overall performance scale. Passing scores were set and compared using 2 standard setting methodologies, using a compensatory and conjunctive model. Inter-rater reliability and the reliability of the pass/fail decision were calculated using Cronbach alpha and Subkoviak methodology, respectively. Overall COSATS scores and pass/fail status were compared with results on the ABCRS oral examination. The pass rate ranged from 85.7% to 90%. Inter-rater reliability (0.85) and reliability of the pass/fail decision (0.87 and 0.84) were high. A low positive correlation (r= 0.25) was seen between the COSATS and oral examination. All individuals who failed the COSATS passed the ABCRS oral examination. COSATS is the first technical skill examination used in national surgical board certification. This study suggests that the current certification process may be failing to identify individuals who have demonstrated technical deficiencies on this standardized assessment tool.

  10. Evaluation of the functional performance and technical quality of an Electronic Documentation System of the Nursing Process.

    PubMed

    de Oliveira, Neurilene Batista; Peres, Heloisa Helena Ciqueto

    2015-01-01

    To evaluate the functional performance and the technical quality of the Electronic Documentation System of the Nursing Process of the Teaching Hospital of the University of São Paulo. exploratory-descriptive study. The Quality Model of regulatory standard 25010 and the Evaluation Process defined under regulatory standard 25040, both of the International Organization for Standardization/International Electrotechnical Commission. The quality characteristics evaluated were: functional suitability, reliability, usability, performance efficiency, compatibility, security, maintainability and portability. The sample was made up of 37 evaluators. in the evaluation of the specialists in information technology, only the characteristic of usability obtained a rate of positive responses of less than 70%. For the nurse lecturers, all the quality characteristics obtained a rate of positive responses of over 70%. The staff nurses of the medical and surgical clinics with experience in using the system) and staff nurses from other units of the hospital and from other health institutions (without experience in using the system) obtained rates of positive responses of more than 70% referent to the functional suitability, usability, and security. However, performance efficiency, reliability and compatibility all obtained rates below the parameter established. the software achieved rates of positive responses of over 70% for the majority of the quality characteristics evaluated.

  11. Expanded Guidance for NASA Systems Engineering. Volume 2: Crosscutting Topics, Special Topics, and Appendices

    NASA Technical Reports Server (NTRS)

    Hirshorn, Steven R.

    2017-01-01

    Historically, most successful NASA projects have depended on effectively blending project management, systems engineering, and technical expertise among NASA, contractors, and third parties. Underlying these successes are a variety of agreements (e.g., contract, memorandum of understanding, grant, cooperative agreement) between NASA organizations or between NASA and other Government agencies, Government organizations, companies, universities, research laboratories, and so on. To simplify the discussions, the term "contract" is used to encompass these agreements. This section focuses on the NASA systems engineering activities pertinent to awarding a contract, managing contract performance, and completing a contract. In particular, NASA systems engineering interfaces to the procurement process are covered, since the NASA engineering technical team plays a key role in the development and evaluation of contract documentation. Contractors and third parties perform activities that supplement (or substitute for) the NASA project technical team accomplishment of the NASA common systems engineering technical process activities and requirements outlined in this guide. Since contractors might be involved in any part of the systems engineering life cycle, the NASA project technical team needs to know how to prepare for, allocate or perform, and implement surveillance of technical activities that are allocated to contractors.

  12. Evaluation Processes Used to Assess the Effectiveness of Vocational-Technical Programs.

    ERIC Educational Resources Information Center

    Bruhns, Arthur E.

    Evaluation is quantitative or qualitative, the criteria determined by or given to the student. The criteria show how close he has come to the program's objectives and the ranking of individual performance. Vocational education programs susceptible to evaluation are listed and relevant evaluative techniques discussed. Graduate interviews concerning…

  13. Development and evaluation of a patient-centred measurement tool for surgeons' non-technical skills.

    PubMed

    Yule, J; Hill, K; Yule, S

    2018-06-01

    Non-technical skills are essential for safe and effective surgery. Several tools to assess surgeons' non-technical skills from the clinician's perspective have been developed. However, a reliable measurement tool using a patient-centred approach does not currently exist. The aim of this study was to translate the existing Non-Technical Skills for Surgeons (NOTSS) tool into a patient-centred evaluation tool. Data were gathered from four cohorts of patients using an iterative four-stage mixed-methods research design. Exploratory and confirmatory factor analyses were performed to establish the psychometric properties of the tool, focusing on validity, reliability, usability and parsimony. Some 534 patients were recruited to the study. A total of 24 patient-centred non-technical skill items were developed in stage 1, and reduced to nine items in stage 2 using exploratory factor analysis. In stage 3, confirmatory factor analysis demonstrated that these nine items each loaded on to one of three factors, with excellent internal consistency: decision-making, leadership, and communication and teamwork. In stage 4, validity testing established that the new tool was independent of physician empathy and predictive of surgical quality. Surgical leadership emerged as the most dominant skill that patients could recognize and evaluate. A novel nine-item assessment tool has been developed. The Patients' Evaluation of Non-Technical Skills (PENTS) tool allows valid and reliable measurement of surgeons' non-technical skills from the patient perspective. © 2018 BJS Society Ltd Published by John Wiley & Sons Ltd.

  14. OTEC modular experiment cold water pipe concept evaluation. Volume III. Appendices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1979-04-01

    The Cold Water Pipe System Design Study was undertaken to evaluate the diverse CWP concepts, recommend the most viable alternatives for a 1984 deployment of the 10 to 40 MWe MEP, and carry out preliminary designs of three concepts. The concept evaluation phase reported involved a systems analysis of design alternatives in the broad categories of rigid walled (with hinges), compliant walled, stockade and bottom mounted buoyant. Quantitative evaluations were made of concept performance, availability, deployment schedule, technical feasibility and cost. CWP concepts were analyzed to determine if they met or could be made to meet established system requirements andmore » could be deployed by 1984. Fabrication, construction and installation plans were developed for successful concepts, and costs were determined in a WBS format. Evaluations were performed on the basis of technical and cost risk. This volume includes the following appendices: (A) materials and associated design criteria; (B) summary of results of dynamic flow and transportation analysis; (C) CWP sizing analysis; (D) CWP thermal performance; and (E) investigation of the APL/ABAM CWP design. (WHK)« less

  15. Randomized clinical trial to evaluate mental practice in enhancing advanced laparoscopic surgical performance.

    PubMed

    Louridas, M; Bonrath, E M; Sinclair, D A; Dedy, N J; Grantcharov, T P

    2015-01-01

    Mental practice, the cognitive rehearsal of a task without physical movement, is known to enhance performance in sports and music. Investigation of this technique in surgery has been limited to basic operations. The purpose of this study was to develop mental practice scripts, and to assess their effect on advanced laparoscopic skills and surgeon stress levels in a crisis scenario. Twenty senior surgical trainees were randomized to either conventional training or mental practice groups, the latter being trained by an expert performance psychologist. Participants' skills were assessed while performing a porcine laparoscopic jejunojejunostomy as part of a crisis scenario in a simulated operating room, using the Objective Structured Assessment of Technical Skill (OSATS) and bariatric OSATS (BOSATS) instruments. Objective and subjective stress parameters were measured, as well as non-technical skills using the Non-Technical Skills for Surgeons rating tool. An improvement in OSATS (P = 0.003) and BOSATS (P = 0.003) scores was seen in the mental practice group compared with the conventional training group. Seven of ten trainees improved their technical performance during the crisis scenario, whereas four of the ten conventionally trained participants deteriorated. Mental imagery ability improved significantly following mental practice training (P = 0.011), but not in the conventional group (P = 0.083). No differences in objective or subjective stress levels or non-technical skills were evident. Mental practice improves technical performance for advanced laparoscopic tasks in the simulated operating room, and allows trainees to maintain or improve their performance despite added stress. © 2014 BJS Society Ltd. Published by John Wiley & Sons Ltd.

  16. CF60 Concrete Composition Design and Application on Fudiankou Xijiang Super Large Bridge

    NASA Astrophysics Data System (ADS)

    Qiu, Yi Mei; Wen, Sen Yuan; Chen, Jun Xiang

    2018-06-01

    Guangxi Wuzhou City Ring Road Fudiankou Xijiang super large bridge CF60 concrete is a new multi-phase composite high-performance concrete, this paper for the Fudiankou Xijiang bridge structure and characteristics of the project, in accordance with the principle of local materials and technical specification requirements, combined with the site conditions of CF60 engineering high performance concrete component materials, proportion and the technical performance, quantify the main physical and mechanical performance index. Analysis main influencing factors of the technical indicators, reasonable adjustment of concrete mix design parameters, and the use of technical means of admixture and multi-function composite admixture of concrete, obtain the optimal proportion of good work, process, mechanical properties stability and durability of engineering properties, recommend and verification of concrete mix; to explore the CF60 high performance concrete Soil in the Fudiankou Xijiang bridge application technology, detection and tracking the quality of concrete construction, concrete structure during the construction of the key technology and control points is proposed, evaluation of CF60 high performance concrete in the actual engineering application effect and benefit to ensure engineering quality of bridge structure and service life, and super long span bridge engineering construction to provide basis and reference.

  17. Implementing assessments of robot-assisted technical skill in urological education: a systematic review and synthesis of the validity evidence.

    PubMed

    Goldenberg, Mitchell G; Lee, Jason Y; Kwong, Jethro C C; Grantcharov, Teodor P; Costello, Anthony

    2018-03-31

    To systematically review and synthesise the validity evidence supporting intraoperative and simulation-based assessments of technical skill in urological robot-assisted surgery (RAS), and make evidence-based recommendations for the implementation of these assessments in urological training. A literature search of the Medline, PsycINFO and Embase databases was performed. Articles using technical skill and simulation-based assessments in RAS were abstracted. Only studies involving urology trainees or faculty were included in the final analysis. Multiple tools for the assessment of technical robotic skill have been published, with mixed sources of validity evidence to support their use. These evaluations have been used in both the ex vivo and in vivo settings. Performance evaluations range from global rating scales to psychometrics, and assessments are carried out through automation, expert analysts, and crowdsourcing. There have been rapid expansions in approaches to RAS technical skills assessment, both in simulated and clinical settings. Alternative approaches to assessment in RAS, such as crowdsourcing and psychometrics, remain under investigation. Evidence to support the use of these metrics in high-stakes decisions is likely insufficient at present. © 2018 The Authors BJU International © 2018 BJU International Published by John Wiley & Sons Ltd.

  18. Development of a model performance-based sign sheeting specification based on the evaluation of nighttime traffic signs using legibility and eye-tracker data : data and analyses.

    DOT National Transportation Integrated Search

    2010-09-01

    This report presents data and technical analyses for Texas Department of Transportation Project 0-5235. This : project focused on the evaluation of traffic sign sheeting performance in terms of meeting the nighttime : driver needs. The goal was to de...

  19. Development and Evaluation of Video Systems for Performance Testing and Student Monitoring. Final Report.

    ERIC Educational Resources Information Center

    Hayes, John; Pulliam, Robert

    A video performance monitoring system was developed by the URS/Matrix Company, under contract to the USAF Human Resources Laboratory and was evaluated experimentally in three technical training settings. Using input from 1 to 8 video cameras, the system provided a flexible combination of signal processing, direct monitor, recording and replay…

  20. 21st Century Educators: Developing and Supporting Great Career and Technical Education Teachers. Special Issues Brief. Revised Edition

    ERIC Educational Resources Information Center

    Jacques, Catherine; Potemski, Amy

    2014-01-01

    This Special Issues Brief from the Center on Great Teachers and Leaders (GTL Center) offers insight into three human capital management policies that are critical for career and technical education (CTE) teachers: certification, performance evaluation, and professional development. CTE teachers are uniquely positioned to improve college and career…

  1. Project Manager’s Guide to the Scientific and Technical Information (STINFO) Program and Technical Publications Process

    DTIC Science & Technology

    1993-12-01

    Iaporta .. y be definitive for the tubjoct proaentod, exploratory in natura, or an evaluation of critical Aubayato• or of technical problema , 4...International Security 9 Social and Natural Science Studies Field 41 Edit: (Type 3) -Entry of an invalid code when Performance Type is "C" or "M" will...analysis SF Foreign area social science research SP Foreign area policy planAing research BF Identifies databases with data on foreign forces or

  2. Application of objective clinical human reliability analysis (OCHRA) in assessment of technical performance in laparoscopic rectal cancer surgery.

    PubMed

    Foster, J D; Miskovic, D; Allison, A S; Conti, J A; Ockrim, J; Cooper, E J; Hanna, G B; Francis, N K

    2016-06-01

    Laparoscopic rectal resection is technically challenging, with outcomes dependent upon technical performance. No robust objective assessment tool exists for laparoscopic rectal resection surgery. This study aimed to investigate the application of the objective clinical human reliability analysis (OCHRA) technique for assessing technical performance of laparoscopic rectal surgery and explore the validity and reliability of this technique. Laparoscopic rectal cancer resection operations were described in the format of a hierarchical task analysis. Potential technical errors were defined. The OCHRA technique was used to identify technical errors enacted in videos of twenty consecutive laparoscopic rectal cancer resection operations from a single site. The procedural task, spatial location, and circumstances of all identified errors were logged. Clinical validity was assessed through correlation with clinical outcomes; reliability was assessed by test-retest. A total of 335 execution errors identified, with a median 15 per operation. More errors were observed during pelvic tasks compared with abdominal tasks (p < 0.001). Within the pelvis, more errors were observed during dissection on the right side than the left (p = 0.03). Test-retest confirmed reliability (r = 0.97, p < 0.001). A significant correlation was observed between error frequency and mesorectal specimen quality (r s = 0.52, p = 0.02) and with blood loss (r s = 0.609, p = 0.004). OCHRA offers a valid and reliable method for evaluating technical performance of laparoscopic rectal surgery.

  3. Validity evidence of non-technical skills assessment instruments in simulated anaesthesia crisis management.

    PubMed

    Jirativanont, T; Raksamani, K; Aroonpruksakul, N; Apidechakul, P; Suraseranivongse, S

    2017-07-01

    We sought to evaluate the validity of two non-technical skills evaluation instruments, the Anaesthetists' Non-Technical Skills (ANTS) behavioural marker system and the Ottawa Global Rating Scale (GRS), to apply them to anaesthesia training. The content validity, response process, internal structure, relations with other variables and consequences were described for validity evidence. Simulated crisis management sessions were initiated during which two trained raters evaluated the performance of postgraduate first-, second- and third-year (PGY-1, PGY-2 and PGY-3) anaesthesia residents. The study included 70 participants, composed of 24 PGY-1, 24 PGY-2 and 22 PGY-3 residents. Both instruments differentiated the non-technical skills of PGY-1 from PGY-3 residents ( P <0.05). Inter-rater agreement was measured using the intraclass correlation coefficient (ICC). For the ANTS instrument, the intraclass correlation coefficients for task management, team-working, situation awareness and decision-making were 0.79, 0.34, 0.81 and 0.70, respectively. For the Ottawa GRS, the intraclass correlation coefficients for overall performance, leadership, problem-solving, situation awareness, resource utilisation and communication skills were 0.86, 0.83, 0.84, 0.87, 0.80 and 0.86, respectively. The Cronbach's alpha for internal consistency of the ANTS instrument was 0.93, and was 0.96 for the Ottawa GRS. There was a high correlation between the ANTS and Ottawa GRS. The raters reported the ease of use of the Ottawa GRS compared to the ANTS. We found sufficient evidence of validity in the ANTS instrument and the Ottawa GRS for the evaluation of non-technical skills in a simulated anaesthesia setting, but the Ottawa GRS was more practical and had higher reliability.

  4. Efficacy of simulation-based trauma team training of non-technical skills. A systematic review.

    PubMed

    Gjeraa, K; Møller, T P; Østergaard, D

    2014-08-01

    Trauma resuscitation is a complex situation, and most organisations have multi-professional trauma teams. Non-technical skills are challenged during trauma resuscitation, and they play an important role in the prevention of critical incidents. Simulation-based training of these is recommended. Our research question was: Does simulation-based trauma team training of non-technical skills have effect on reaction, learning, behaviour or patient outcome? The authors searched PubMed, EMBASE and the Cochrane Library and found 13 studies eligible for analysis. We described and compared the educational interventions and the evaluations of effect according to the four Kirkpatrick levels: reaction, learning (knowledge, skills, attitudes), behaviour (in a clinical setting) and patient outcome. No studies were randomised, controlled and blinded, resulting in a moderate to high risk of bias. The multi-professional trauma teams had positive reactions to simulation-based training of non-technical skills. Knowledge and skills improved in all studies evaluating the effect on learning. Three studies found improvements in team performance (behaviour) in the clinical setting. One of these found difficulties in maintaining these skills. Two studies evaluated on patient outcome, of which none showed improvements in mortality, complication rate or duration of hospitalisation. A significant effect on learning was found after simulation-based training of the multi-professional trauma team in non-technical skills. Three studies demonstrated significantly increased clinical team performance. No effect on patient outcome was found. All studies had a moderate to high risk of bias. More comprehensive randomised studies are needed to evaluate the effect on patient outcome. © 2014 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  5. Evaluation of interaction properties of geosynthetics in cohesive soils : lab and field pull out tests : technical summary.

    DOT National Transportation Integrated Search

    2004-07-01

    The objective of this research was to evaluate the pullout performance of geogrids and geotextiles in silty-clay soils. The results were correlated for various types of geogrid and geotextile reinforcements. This report presents an evaluation of the ...

  6. Further Investigations of Content Analytic Techniques for Extracting the Differentiating Information Contained in the Narrative Sections of Performance Evaluations for Navy Enlisted Personnel. Technical Report No. 75-1.

    ERIC Educational Resources Information Center

    Ramsey-Klee, Diane M.; Richman, Vivian

    The purpose of this research is to develop content analytic techniques capable of extracting the differentiating information in narrative performance evaluations for enlisted personnel in order to aid in the process of selecting personnel for advancement, duty assignment, training, or quality retention. Four tasks were performed. The first task…

  7. Non-Functional Property Driven Service Governance: Performance Implications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Yan; Zhu, Liming; Bass, Len

    2007-09-17

    Service governance is a set of businesses processes, policies and technical solutions that support enterprises in their implementation and management of their SOA. The decisions of service governance, especially concerning service boundaries at the enterprise level, influence the deployment topology of business services across or within business organizations. Deployment topologies are realized by integration technologies such as Enterprise Service Bus (ESB). Service governance and technical solutions interact in a subtle way including through communication patterns and protocols between services and ESBs, as well as the deployment and configuration of ESB. These factors have a strong influence on the Non- Functionalmore » Properties (NFP) of a SOA solution. A systematic approach is essential to understand alternative technical solutions for a specific service governance decision. This paper proposes a modeling approach to evaluate the performance-related NFP impacts when mapping service governance to technical solutions using an ESB. This approach is illustrated by the quantitative performance analysis of a real« less

  8. Technical quality of root canal treatment performed by undergraduate students using hand instrumentation: a meta-analysis.

    PubMed

    Ribeiro, D M; Réus, J C; Felippe, W T; Pacheco-Pereira, C; Dutra, K L; Santos, J N; Porporatti, A L; De Luca Canto, G

    2018-03-01

    The technical quality of root canal treatment (RCT) may impact on the outcome. The quality of education received during undergraduate school may be linked to the quality of treatment provided in general dental practice. In this context, the aim of this systematic review was to answer the following focused questions: (i) What is the frequency of acceptable technical quality of root fillings, assessed radiographically, performed by undergraduate students? (ii) What are the most common errors assessed radiographically and reported in these treatments? For this purpose, articles that evaluated the quality of root fillings performed by undergraduate students were selected. Data were collected based on predetermined criteria. The key features from the included studies were extracted. GRADE-tool assessed the quality of the evidence. MAStARI evaluated the methodological quality, and a meta-analysis on all studies was conducted. At the end of the screening, 24 articles were identified. Overall frequency of acceptable technical quality of root fillings was 48%. From this total, 52% related to anterior teeth, 49% to premolars and 26% to molars. The main procedural errors reported were ledge formation, furcation perforation, apical transportation and apical perforation. The heterogeneity amongst the studies was high (84-99%). Five studies had a high risk of bias, eight had a moderate risk, and 11 had low risk. The overall quality of evidence identified was very low. The conclusion was that technical quality of root fillings performed by undergraduate students is low, which may reveal that endodontic education has limited achievement at undergraduate level. A plan to improve the quality of root fillings, and by extrapolation the overall quality of root canal treatment, should be discussed by the staff responsible for endodontic education and training. © 2017 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  9. Evaluating the influence of goal setting on intravenous catheterization skill acquisition and transfer in a hybrid simulation training context.

    PubMed

    Brydges, Ryan; Mallette, Claire; Pollex, Heather; Carnahan, Heather; Dubrowski, Adam

    2012-08-01

    Educators often simplify complex tasks by setting learning objectives that focus trainees on isolated skills rather than the holistic task. We designed 2 sets of learning objectives for intravenous catheterization using goal setting theory. We hypothesized that setting holistic goals related to technical, cognitive, and communication skills would result in superior holistic performance, whereas setting isolated goals related to technical skills would result in superior technical performance. We randomly assigned practicing health care professionals to set holistic (n = 14) or isolated (n = 15) goals. All watched an instructional video and studied a list of 9 goals specific to their group. Participants practiced independently in a hybrid simulation (standardized patient combined with an arm simulator). The first and the last practice trials were videotaped for analysis. One-week later, participants completed a transfer test in another hybrid simulation scenario. Blinded experts evaluated performance on all 3 trials using the Direct Observation of Procedural Skills tool. The holistic group scored higher than the isolated group on the holistic Direct Observation of Procedural Skills score for all 3 trials [mean (SD), 45.0 (9.16) vs. 38.4 (9.17); P = 0.01]. The isolated group did not perform better than the holistic group on the technical skills score [10.3 (2.73) vs. 11.6 (3.01); P = 0.11]. Our results suggest that asking learners to set holistic goals did not interfere with their attaining competent holistic and technical skills during hybrid simulation training. This exploratory trial provides preliminary evidence for how to consider integrating hybrid simulation into medical curricula and for the design of learning goals in simulation-based education.

  10. Technical efficiency of Shiraz school of medicine in research and education domains: a data envelopment analysis.

    PubMed

    Delavari, Somayeh; Rezaee, Rita; Hatam, Nahid; Delavari, Sajad

    2016-01-01

    Efficiency evaluation of universities and faculties is one of the tools that help managers to identify the departments' strengths and weakness. The main objective of the present research was to measure and compare the technical efficiency of Shiraz school of medicine departments using Data Envelopment Analysis (DEA) technique. This cross-sectional and retrospective study was performed on clinical and non-clinical departments in research and education domains over the period of 2006 to 2011. Different inputs and outputs were considered for research and educational domain separately. Efficiency was measured based on the observed optimal performance. Findings showed that pathology and anatomy departments achieved the score of 100 in technical efficiency in education during 2006 to 2011. During this period, parasitology, psychiatric and pediatrics department's achieved the score of 100 for technical efficiency in research domain. The lowest mean of relative educational efficiency belonged to orthopedic department; as to relative research efficiency, the lowest mean was shown in orthopedics and genetics departments. The mean technical efficiency of non-medical departments in education and research domain was 91.93 and 76.08, respectively, while the mean technical efficiency of the clinical department in educational and research fields was 91.02 and 82.23, respectively. Using multiple input and output in DEA technique provided a comprehensive evaluation of efficiency in Shiraz school of medicine departments. The DEA could successfully estimate the technical efficiency of the departments in research and educational fields. Moreover, the deficiency in each department was found; this could help them to plan for improvement.

  11. Merit Pay and Faculty Evaluation.

    ERIC Educational Resources Information Center

    Hudgins, James L.

    A program linking merit pay and faculty evaluation was initiated at Sumter Area Technical College (SATC) in Sumter, South Carolina, in 1978. The performance-based evaluation system focuses on three elements: the job description, which identifies professional responsibilities and how they relate to the college's mission; the individual action plan;…

  12. 34 CFR 300.601 - State performance plans and data collection.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 34 Education 2 2011-07-01 2010-07-01 true State performance plans and data collection. 300.601... Monitoring, Technical Assistance, and Enforcement § 300.601 State performance plans and data collection. (a) General. Not later than December 3, 2005, each State must have in place a performance plan that evaluates...

  13. Assessing Technical Competence in Surgical Trainees: A Systematic Review.

    PubMed

    Szasz, Peter; Louridas, Marisa; Harris, Kenneth A; Aggarwal, Rajesh; Grantcharov, Teodor P

    2015-06-01

    To systematically examine the literature describing the methods by which technical competence is assessed in surgical trainees. The last decade has witnessed an evolution away from time-based surgical education. In response, governing bodies worldwide have implemented competency-based education paradigms. The definition of competence, however, remains elusive, and the impact of these education initiatives in terms of assessment methods remains unclear. A systematic review examining the methods by which technical competence is assessed was conducted by searching MEDLINE, EMBASE, PsychINFO, and the Cochrane database of systematic reviews. Abstracts of retrieved studies were reviewed and those meeting inclusion criteria were selected for full review. Data were retrieved in a systematic manner, the validity and reliability of the assessment methods was evaluated, and quality was assessed using the Grading of Recommendations Assessment, Development and Evaluation classification. Of the 6814 studies identified, 85 studies involving 2369 surgical residents were included in this review. The methods used to assess technical competence were categorized into 5 groups; Likert scales (37), benchmarks (31), binary outcomes (11), novel tools (4), and surrogate outcomes (2). Their validity and reliability were mostly previously established. The overall Grading of Recommendations Assessment, Development and Evaluation for randomized controlled trials was high and low for the observational studies. The definition of technical competence continues to be debated within the medical literature. The methods used to evaluate technical competence predominantly include instruments that were originally created to assess technical skill. Very few studies identify standard setting approaches that differentiate competent versus noncompetent performers; subsequently, this has been identified as an area with great research potential.

  14. LABORATORY EVALUATION OF SIX NEW/MODIFIED PORTABLE X-RAY FLUORESCENCE SPECTROMETERS FOR THE MEASUREMENT OF LEAD IN CHARACTERIZED PAINT FILMS AND RESEARCH MATERIAL BOARDS (TECHNICAL REPORT)

    EPA Science Inventory

    A laboratory study was performed in 1994-1995 to identify and estimate the influence of key characteristics for evaluating the performance of portable X-ray fluorescence (XRF) spectrometers. Six new/modified spectrometers, including HNU SEFA-Pb, Metorex X-MET, Niton X-L, Radiat...

  15. Collision avoidance system cost-benefit analysis : volume I - technical manual

    DOT National Transportation Integrated Search

    1981-09-01

    Collision-avoidance systems under development in the U.S.A., Japan and Germany were evaluated. The performance evaluation showed that the signal processing and the control law of a system were the key parameters that decided the system's capability, ...

  16. Evaluation of Phase II of the SmarTraveler advanced traveler information system : operational test

    DOT National Transportation Integrated Search

    1994-07-31

    Under contract to the Massachusetts Highway Department, the Central Transportation : Planning Staff (technical staff to the Boston MPO) chose Multisystems, Inc. of : Cambridge, Massachusetts, to perform an evaluation of Phase II of the SmarTraveler :...

  17. Technical Submission Form: Technical Specification of a Wave Energy Farm.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roberts, Jesse D.; Nielsen, Kim; Kennedy, Ben

    The Wave - SPARC project developed the Technology Performance Level (TPL) assessment procedure based on a rigorous Systems Engineering exercise. The TPL assessment allows a whole system evaluation of Wave Energy Conversion Technology by measuring it against the requirements determined through the Systems Engineering exercise. The TPL assessment is intended to be useful in technology evaluation; in technology innovation; in allocation of public or priva te investment, and; in making equipment purchasing decisions. This Technical Submission Form (TSF) serves the purpose of collecting relevant and complete information, in a technology agnostic way, to allow TPL assessment s to be mademore » by third party assessor s. The intended usage of this document is that the organization or people that are performing the role of developers or promoters of a particular technology will use this form to provide the information necessary for the organization or people who are perf orming the assessor role to use the TPL assessment.« less

  18. A performance evaluation of the IBM 370/XT personal computer

    NASA Technical Reports Server (NTRS)

    Dominick, Wayne D. (Editor); Triantafyllopoulos, Spiros

    1984-01-01

    An evaluation of the IBM 370/XT personal computer is given. This evaluation focuses primarily on the use of the 370/XT for scientific and technical applications and applications development. A measurement of the capabilities of the 370/XT was performed by means of test programs which are presented. Also included is a review of facilities provided by the operating system (VM/PC), along with comments on the IBM 370/XT hardware configuration.

  19. Testing the performance of technical trading rules in the Chinese markets based on superior predictive test

    NASA Astrophysics Data System (ADS)

    Wang, Shan; Jiang, Zhi-Qiang; Li, Sai-Ping; Zhou, Wei-Xing

    2015-12-01

    Technical trading rules have a long history of being used by practitioners in financial markets. The profitable ability and efficiency of technical trading rules are yet controversial. In this paper, we test the performance of more than seven thousand traditional technical trading rules on the Shanghai Securities Composite Index (SSCI) from May 21, 1992 through June 30, 2013 and China Securities Index 300 (CSI 300) from April 8, 2005 through June 30, 2013 to check whether an effective trading strategy could be found by using the performance measurements based on the return and Sharpe ratio. To correct for the influence of the data-snooping effect, we adopt the Superior Predictive Ability test to evaluate if there exists a trading rule that can significantly outperform the benchmark. The result shows that for SSCI, technical trading rules offer significant profitability, while for CSI 300, this ability is lost. We further partition the SSCI into two sub-series and find that the efficiency of technical trading in sub-series, which have exactly the same spanning period as that of CSI 300, is severely weakened. By testing the trading rules on both indexes with a five-year moving window, we find that during the financial bubble from 2005 to 2007, the effectiveness of technical trading rules is greatly improved. This is consistent with the predictive ability of technical trading rules which appears when the market is less efficient.

  20. Systematic review of coaching to enhance surgeons' operative performance.

    PubMed

    Min, Hyeyoun; Morales, Dianali Rivera; Orgill, Dennis; Smink, Douglas S; Yule, Steven

    2015-11-01

    There is increasing attention on the coaching of surgeons and trainees to improve performance but no comprehensive review on this topic. The purpose of this review is to summarize the quantity and the quality of studies involving surgical coaching methods and their effectiveness. We performed a systematic literature search through PubMed and PsychINFO by using predefined inclusion criteria. Evidence for main outcome categories was evaluated with the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) system and the Medical Education Research Study Quality Instrument (MERSQI). Of a total 3,063 articles, 23 met our inclusion criteria; 4 randomized controlled trials and 19 observational studies. We categorized the articles into 4 groups on the basis of the outcome studied: perception, attitude and opinion; technical skills; nontechnical skills; and performance measures. Overall strength of evidence for each outcome groups was as follows: Perception, attitude, and opinion (Grading of Recommendations Assessment, Development, and Evaluation: Very Low, Medical Education Research Study Quality Instrument [MERSQI]: 10); technical skills (randomized controlled trials: High, 13.1; Observation studies: Very Low, 11.5); nontechnical skills (Very Low, 12.4) and performance measures (Very Low, 13.6). Simulation was the most used setting for coaching; more than half of the studies deployed an experienced surgeon as a coach and showed that coaching was effective. Surgical coaching interventions have a positive impact on learners' perception and attitudes, their technical and nontechnical skills, and performance measures. Evidence of impact on patient outcomes was limited, and the quality of research studies was variable. Despite this, our systematic review of different coaching interventions will benefit future coaching strategies and implementation to enhance operative performance. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Career Enhancement Program for the Industries of the Shenandoah Valley of Virginia. Performance Report.

    ERIC Educational Resources Information Center

    Merlin, Shirley B.

    This document contains the performance report, external evaluation, and curricula for the Career Enhancement Program, a workplace literacy partnership conducted by James Madison University and Massanutten Technical Center for five companies in Virginia. The performance report describes how the project delivered individualized workplace literacy…

  2. 48 CFR 1352.215-75 - Evaluation criteria.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... relative importance among the technical evaluation factors.] Based upon the results of the integrated... as the offeror's planned management of consultants and subcontractors, if applicable. Factor 2... likelihood that that offeror can successfully perform the contract requirements and the degree of the risk of...

  3. Friction management on Kansas Department of Transportation highways : technical summary.

    DOT National Transportation Integrated Search

    2017-04-01

    The objectives of this study are to evaluate the performance of a local aggregate in HFST and to evaluate : the 3-dimensional laser profiler for measuring pavement texture. Slab specimens of hot-mix asphalt : (HMA) were compacted in the laboratory an...

  4. High fidelity simulation based team training in urology: a preliminary interdisciplinary study of technical and nontechnical skills in laparoscopic complications management.

    PubMed

    Lee, Jason Y; Mucksavage, Phillip; Canales, Cecilia; McDougall, Elspeth M; Lin, Sharon

    2012-04-01

    Simulation based team training provides an opportunity to develop interdisciplinary communication skills and address potential medical errors in a high fidelity, low stakes environment. We evaluated the implementation of a novel simulation based team training scenario and assessed the technical and nontechnical performance of urology and anesthesiology residents. Urology residents were randomly paired with anesthesiology residents to participate in a simulation based team training scenario involving the management of 2 scripted critical events during laparoscopic radical nephrectomy, including the vasovagal response to pneumoperitoneum and renal vein injury during hilar dissection. A novel kidney surgical model and a high fidelity mannequin simulator were used for the simulation. A debriefing session followed each simulation based team training scenario. Assessments of technical and nontechnical performance were made using task specific checklists and global rating scales. A total of 16 residents participated, of whom 94% rated the simulation based team training scenario as useful for communication skill training. Also, 88% of urology residents believed that the kidney surgical model was useful for technical skill training. Urology resident training level correlated with technical performance (p=0.004) and blood loss during renal vein injury management (p=0.022) but not with nontechnical performance. Anesthesia resident training level correlated with nontechnical performance (p=0.036). Urology residents consistently rated themselves higher on nontechnical performance than did faculty (p=0.033). Anesthesia residents did not differ in the self-assessment of nontechnical performance compared to faculty assessments. Residents rated the simulation based team training scenario as useful for interdisciplinary communication skill training. Urology resident training level correlated with technical performance but not with nontechnical performance. Urology residents consistently overestimated their nontechnical performance. Copyright © 2012 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  5. Designs and performance of three new microprocessor-controlled knee joints.

    PubMed

    Thiele, Julius; Schöllig, Christina; Bellmann, Malte; Kraft, Marc

    2018-02-09

    A crossover design study with a small group of subjects was used to evaluate the performance of three microprocessor-controlled exoprosthetic knee joints (MPKs): C-Leg 4, Plié 3 and Rheo Knee 3. Given that the mechanical designs and control algorithms of the joints determine the user outcome, the influence of these inherent differences on the functional characteristics was investigated in this study. The knee joints were evaluated during level-ground walking at different velocities in a motion analysis laboratory. Additionally, technical analyses using patents, technical documentations and X-ray computed tomography (CT) for each knee joint were performed. The technical analyses showed that only C-Leg 4 and Rheo Knee 3 allow microprocessor-controlled adaptation of the joint resistances for different gait velocities. Furthermore, Plié 3 is not able to provide stance extension damping. The biomechanical results showed that only if a knee joint adapts flexion and extension resistances by the microprocessor all known advantages of MPKs can become apparent. But not all users may benefit from the examined functions: e.g. a good accommodation to fast walking speeds or comfortable stance phase flexion. Hence, a detailed comparison of user demands and performance of the designated knee joint is mandatory to ensure a maximum in user outcome.

  6. Oxford NOTECHS II: a modified theatre team non-technical skills scoring system.

    PubMed

    Robertson, Eleanor R; Hadi, Mohammed; Morgan, Lauren J; Pickering, Sharon P; Collins, Gary; New, Steve; Griffin, Damian; Griffin, Damien; McCulloch, Peter; Catchpole, Ken C

    2014-01-01

    We previously developed and validated the Oxford NOTECHS rating system for evaluating the non-technical skills of an entire operating theatre team. Experience with the scale identified the need for greater discrimination between levels of performance within the normal range. We report here the development of a modified scale (Oxford NOTECHS II) to facilitate this. The new measure uses an eight-point instead of a four point scale to measure each dimension of non-technical skills, and begins with a default rating of 6 for each element. We evaluated this new scale in 297 operations at five NHS sites in four surgical specialities. Measures of theatre process reliability (glitch count) and compliance with the WHO surgical safety checklist were scored contemporaneously, and relationships with NOTECHS II scores explored. Mean team Oxford NOTECHS II scores was 73.39 (range 37-92). The means for surgical, anaesthetic and nursing sub-teams were 24.61 (IQR 23, 27); 24.22 (IQR 23, 26) and 24.55 (IQR 23, 26). Oxford NOTECHS II showed good inter-rater reliability between human factors and clinical observers in each of the four domains. Teams with high WHO compliance had higher mean Oxford NOTECHS II scores (74.5) than those with low compliance (71.1) (p = 0.010). We observed only a weak correlation between Oxford NOTECHS II scores and glitch count; r = -0.26 (95% CI -0.36 to -0.15). Oxford NOTECHS II scores did not vary significantly between 5 different hospital sites, but a significant difference was seen between specialities (p = 0.001). Oxford NOTECHS II provides good discrimination between teams while retaining reliability and correlation with other measures of teamwork performance, and is not confounded by technical performance. It is therefore suitable for combined use with a technical performance scale to provide a global description of operating theatre team performance.

  7. NASA and Deere to study effects of low-g on iron processing

    NASA Technical Reports Server (NTRS)

    1981-01-01

    A technical exchange agreement to study the effects of processing iron alloys in microgravity is described. Alloy solidification experiments are to be performed in the low-g facilities at Marshall Space Center. Deere is to prepare and evaluate the samples, and perform thermal characterization studies of the furnace used for melting and solidifying the samples. Experiment planning and analysis are to be performed jointly and data shared between the two parties. The technical exchange concept, developed by NASA to involve the private sector in low gravity research programs, is described. Other low gravity processing fields in which industry is invited to participate are listed.

  8. 77 FR 52318 - Notice of Submission for OMB Review; Office of Planning, Evaluation and Policy Development; Study...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-29

    ... DEPARTMENT OF EDUCATION Notice of Submission for OMB Review; Office of Planning, Evaluation and..., including technical assistance to improve the quality of evaluations and performance reporting; and how to.... Department of Education, 400 Maryland Avenue SW., LBJ, Washington, DC 20202-4537. Copies of the proposed...

  9. 77 FR 52707 - Notice of Submission for OMB Review; Office of Planning, Evaluation and Policy Development; Study...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-30

    ... DEPARTMENT OF EDUCATION Notice of Submission for OMB Review; Office of Planning, Evaluation and..., including technical assistance to improve the quality of evaluations and performance reporting; and how to.... Department of Education, 400 Maryland Avenue SW, LBJ, Washington, DC 20202-4537. Copies of the proposed...

  10. 78 FR 29338 - Applications for New Award; Technical Assistance To Improve State Data Capacity-National...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-20

    ... formative and summative evaluations of the project; Note: The following Web site provides more information... plan, linked to the project's logic model, for a formative evaluation of the project's activities. The plan must describe how the formative evaluation will use clear performance objectives to ensure...

  11. Understanding Usefulness in Human-Computer Interaction to Enhance User Experience Evaluation

    ERIC Educational Resources Information Center

    MacDonald, Craig Matthew

    2012-01-01

    The concept of usefulness has implicitly played a pivotal role in evaluation research, but the meaning of usefulness has changed over time from system reliability to user performance and learnability/ease of use for non-experts. Despite massive technical and social changes, usability remains the "gold standard" for system evaluation.…

  12. Testing of state roadside safety systems. Volume I, Technical report

    DOT National Transportation Integrated Search

    1999-04-01

    The purpose of this study is to crash test and evaluate new or modified roadside safety hardware and, where necessary, redesign the devices to improve their impact performance. The three major areas addressed in this study are the impact performance ...

  13. Measuring School Climate for Gauging Principal Performance: A Review of the Validity and Reliability of Publicly Accessible Measures. A Quality School Leadership Issue Brief

    ERIC Educational Resources Information Center

    Clifford, Matthew; Menon, Roshni; Gangi, Tracy; Condon, Christopher; Hornung, Katie

    2012-01-01

    This policy brief provides principal evaluation system designers information about the technical soundness and cost (i.e., time requirements) of publicly available school climate surveys. The authors focus on the technical soundness of school climate surveys because they believe that using validated and reliable surveys as an outcomes measure can…

  14. A Planning Study for the Conversion of Recorded Books and Magazines from Rigid Discs to Cassettes and Flexible Discs. Final Report.

    ERIC Educational Resources Information Center

    Innovative Systems Research, Inc., Pennsauken, NJ.

    Twelve different conversion plans were delineated and evaluated in the performance of this study effort. An indepth technical, financial, and cost/benefit analysis was included. One plan was determined to be distinctively more cost-effective than any of the other plans because it provided a technically feasible system that assured the maximum…

  15. Washington's Community and Technical Colleges' Student Achievement Initiative: Lessons Learned since the 2012 Revision and Considerations for New Allocation Model. Research Report 16-1

    ERIC Educational Resources Information Center

    Washington State Board for Community and Technical Colleges, 2016

    2016-01-01

    In January 2012, a system-wide task force came together for a nearly year-long process of revising the community and technical college system's performance-based funding (PBF) system, the Student Achievement Initiative. This review was consistent with national experts' recommendations for continuous evaluation of PBF systems to ensure overall…

  16. PRACA Enhancement Pilot Study Report: Engineering for Complex Systems Program (formerly Design for Safety), DFS-IC-0006

    NASA Technical Reports Server (NTRS)

    Korsmeyer, David; Schreiner, John

    2002-01-01

    This technology evaluation report documents the findings and recommendations of the Engineering for Complex Systems Program (formerly Design for Safety) PRACA Enhancement Pilot Study of the Space Shuttle Program's (SSP's) Problem Reporting and Corrective Action (PRACA) System. A team at NASA Ames Research Center (ARC) performed this Study. This Study was initiated as a follow-on to the NASA chartered Shuttle Independent Assessment Team (SIAT) review (performed in the Fall of 1999) which identified deficiencies in the current PRACA implementation. The Pilot Study was launched with an initial qualitative assessment and technical review performed during January 2000 with the quantitative formal Study (the subject of this report) started in March 2000. The goal of the PRACA Enhancement Pilot Study is to evaluate and quantify the technical aspects of the SSP PRACA systems and recommend enhancements to address deficiencies and in preparation for future system upgrades.

  17. Cricothyroidotomy In Situ Simulation Curriculum (CRIC Study): Training Residents for Rare Procedures.

    PubMed

    Petrosoniak, Andrew; Ryzynski, Agnes; Lebovic, Gerald; Woolfrey, Karen

    2017-04-01

    Technical skill acquisition for rare procedures can be challenging given the few real-life training opportunities. In situ simulation (ISS), a training technique that takes place in the actual workplace, is a promising method to promote environmental fidelity for rare procedures. This study evaluated a simulation-based technical skill curriculum for cricothyroidotomy using deliberate practice, followed by an ISS evaluation session. Twenty emergency medicine residents participated in a two-part curriculum to improve cricothryoidotomy performance. A pretest established participant baseline technical skill. The training session consisted of two parts, didactic teaching followed by deliberate practice using a task-training manikin. A posttest consisted of an unannounced, high-fidelity ISS, during an emergency department shift. The primary outcome was the mean performance time between the pretest and posttest sessions. Skill performance was also evaluated using a checklist scale and global rating scale. Cricothyroidotomy performance time improved significantly from pretest to posttest sessions (mean difference, 59 seconds; P < 0.0001). Both checklist and global rating scales improved significantly from the pretest to the posttest with a mean difference of 1.82 (P = 0.002) and 6.87 (P = 0.0025), respectively. Postcourse survey responses were favorable for both the overall curriculum experience and the unannounced ISS. This pilot study demonstrated that unannounced ISS is feasible and can be used to effectively measure cricothyroidotomy performance among EM residents. After a two-part training session consisting of didactic learning and deliberate practice, improved cricothyroidotomy skill performance was observed during an unannounced ISS in the emergency department. The integration of ISS in cricothyroidotomy training represents a promising approach; however, further study is needed to establish its role.

  18. 48 CFR 1352.215-75 - Evaluation criteria.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... relative importance among the technical evaluation factors.] Based upon the results of the integrated... and manage the contract and the means that will be used to accomplish the contract requirements. The... non-performance. Factor 3—KEY PERSONNEL. The education, experience, and accomplishments of key...

  19. 48 CFR 1352.215-75 - Evaluation criteria.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... relative importance among the technical evaluation factors.] Based upon the results of the integrated... and manage the contract and the means that will be used to accomplish the contract requirements. The... non-performance. Factor 3—KEY PERSONNEL. The education, experience, and accomplishments of key...

  20. 48 CFR 1352.215-75 - Evaluation criteria.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... relative importance among the technical evaluation factors.] Based upon the results of the integrated... and manage the contract and the means that will be used to accomplish the contract requirements. The... non-performance. Factor 3—KEY PERSONNEL. The education, experience, and accomplishments of key...

  1. Hydraulic Hybrid Vehicle Publications | Transportation Research | NREL

    Science.gov Websites

    Hydraulic Hybrid Vehicle Publications Hydraulic Hybrid Vehicle Publications The following technical papers and fact sheets provide information about NREL's hydraulic hybrid fleet vehicle evaluations . Refuse Trucks Project Startup: Evaluating the Performance of Hydraulic Hybrid Refuse Vehicles. Bob

  2. Mental Preparation and Evaluation: A Sportpsychological Project with the Swiss Orienteering National Team.

    ERIC Educational Resources Information Center

    Venzl, Reto

    1994-01-01

    Lists the training themes and levels of intervention of a psychological orienteering project for Swiss athletes. Presents an outline for preparation and evaluation of team or individual performance over time on technical, physical, mental, and environmental aspects of orienteering. (SV)

  3. 48 CFR 315.307 - Proposal revisions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... appropriate; and (2) An evaluation of technical factors by the technical evaluation panel, as necessary. The technical evaluation panel may rescore and re-rank technical proposals in the competitive range and prepare a technical evaluation report. To the extent practicable, the same evaluators who reviewed the...

  4. Comparison of pre-processing methods for multiplex bead-based immunoassays.

    PubMed

    Rausch, Tanja K; Schillert, Arne; Ziegler, Andreas; Lüking, Angelika; Zucht, Hans-Dieter; Schulz-Knappe, Peter

    2016-08-11

    High throughput protein expression studies can be performed using bead-based protein immunoassays, such as the Luminex® xMAP® technology. Technical variability is inherent to these experiments and may lead to systematic bias and reduced power. To reduce technical variability, data pre-processing is performed. However, no recommendations exist for the pre-processing of Luminex® xMAP® data. We compared 37 different data pre-processing combinations of transformation and normalization methods in 42 samples on 384 analytes obtained from a multiplex immunoassay based on the Luminex® xMAP® technology. We evaluated the performance of each pre-processing approach with 6 different performance criteria. Three performance criteria were plots. All plots were evaluated by 15 independent and blinded readers. Four different combinations of transformation and normalization methods performed well as pre-processing procedure for this bead-based protein immunoassay. The following combinations of transformation and normalization were suitable for pre-processing Luminex® xMAP® data in this study: weighted Box-Cox followed by quantile or robust spline normalization (rsn), asinh transformation followed by loess normalization and Box-Cox followed by rsn.

  5. Toward an objective assessment of technical skills: a national survey of surgical program directors in Saudi Arabia.

    PubMed

    Alkhayal, Abdullah; Aldhukair, Shahla; Alselaim, Nahar; Aldekhayel, Salah; Alhabdan, Sultan; Altaweel, Waleed; Magzoub, Mohi Elden; Zamakhshary, Mohammed

    2012-01-01

    After almost a decade of implementing competency-based programs in postgraduate training programs, the assessment of technical skills remains more subjective than objective. National data on the assessment of technical skills during surgical training are lacking. We conducted this study to document the assessment tools for technical skills currently used in different surgical specialties, their relationship with remediation, the recommended tools from the program directors' perspective, and program directors' attitudes toward the available objective tools to assess technical skills. This study was a cross-sectional survey of surgical program directors (PDs). The survey was initially developed using a focus group and was then sent to 116 PDs. The survey contains demographic information about the program, the objective assessment tools used, and the reason for not using assessment tools. The last section discusses the recommended tools to be used from the PDs' perspective and the PDs' attitude and motivation to apply these tools in each program. The associations between the responses to the assessment questions and remediation were statistically evaluated. Seventy-one (61%) participants responded. Of the respondents, 59% mentioned using only nonstandardized, subjective, direct observation for technical skills assessment. Sixty percent use only summative evaluation, whereas 15% perform only formative evaluations of their residents, and the remaining 22% conduct both summative and formative evaluations of their residents' technical skills. Operative portfolios are kept by 53% of programs. The percentage of programs with mechanisms for remediation is 29% (19 of 65). The survey showed that surgical training programs use different tools to assess surgical skills competency. Having a clear remediation mechanism was highly associated with reporting remediation, which reflects the capability to detect struggling residents. Surgical training leadership should invest more in standardizing the assessment of surgical skills.

  6. Comparative performance of rubber modified hot mix asphalt under ALF loading : technical summary.

    DOT National Transportation Integrated Search

    2004-07-01

    The objectives of this study were to evaluate the overall performance under accelerated loading of hot mix asphalt mixtures containing powdered rubber modifier (PRM) as compared to similar mixes with conventional HMA and to optimize the use of these ...

  7. Development of field performance evaluation tools and program for pavement marking materials : technical report

    DOT National Transportation Integrated Search

    2011-03-01

    Historically the prequalification or selection of pavement marking materials (PMMs) is mainly based on : product specifications and lab testing, which do not correlate well with the field performance of the products. : On the other hand, there is no ...

  8. Development of Performance Indicators for DOTD programs : technical summary.

    DOT National Transportation Integrated Search

    1998-05-01

    The objective of the research was to evaluate the performance indicators currently in use at DOTD and determine if any deficiencies exist with those that are sent forward as a part of the executive budget. A further objective was to examine the proce...

  9. Twenty-fifth water reactor safety information meeting: Proceedings. Volume 2: Human reliability analysis and human performance evaluation; Technical issues related to rulemakings; Risk-informed, performance-based initiatives; High burn-up fuel research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Monteleone, S.

    1998-03-01

    This three-volume report contains papers presented at the conference. The papers are printed in the order of their presentation in each session and describe progress and results of programs in nuclear safety research conducted in this country and abroad. Foreign participation in the meeting included papers presented by researchers from France, Japan, Norway, and Russia. The titles of the papers and the names of the authors have been updated and may differ from those that appeared in the final program of the meeting. This volume contains the following: (1) human reliability analysis and human performance evaluation; (2) technical issues relatedmore » to rulemakings; (3) risk-informed, performance-based initiatives; and (4) high burn-up fuel research. Selected papers have been indexed separately for inclusion in the Energy Science and Technology Database.« less

  10. Removing Batch Effects from Longitudinal Gene Expression - Quantile Normalization Plus ComBat as Best Approach for Microarray Transcriptome Data

    PubMed Central

    Müller, Christian; Schillert, Arne; Röthemeier, Caroline; Trégouët, David-Alexandre; Proust, Carole; Binder, Harald; Pfeiffer, Norbert; Beutel, Manfred; Lackner, Karl J.; Schnabel, Renate B.; Tiret, Laurence; Wild, Philipp S.; Blankenberg, Stefan

    2016-01-01

    Technical variation plays an important role in microarray-based gene expression studies, and batch effects explain a large proportion of this noise. It is therefore mandatory to eliminate technical variation while maintaining biological variability. Several strategies have been proposed for the removal of batch effects, although they have not been evaluated in large-scale longitudinal gene expression data. In this study, we aimed at identifying a suitable method for batch effect removal in a large study of microarray-based longitudinal gene expression. Monocytic gene expression was measured in 1092 participants of the Gutenberg Health Study at baseline and 5-year follow up. Replicates of selected samples were measured at both time points to identify technical variability. Deming regression, Passing-Bablok regression, linear mixed models, non-linear models as well as ReplicateRUV and ComBat were applied to eliminate batch effects between replicates. In a second step, quantile normalization prior to batch effect correction was performed for each method. Technical variation between batches was evaluated by principal component analysis. Associations between body mass index and transcriptomes were calculated before and after batch removal. Results from association analyses were compared to evaluate maintenance of biological variability. Quantile normalization, separately performed in each batch, combined with ComBat successfully reduced batch effects and maintained biological variability. ReplicateRUV performed perfectly in the replicate data subset of the study, but failed when applied to all samples. All other methods did not substantially reduce batch effects in the replicate data subset. Quantile normalization plus ComBat appears to be a valuable approach for batch correction in longitudinal gene expression data. PMID:27272489

  11. HKHC Community Dashboard: design, development, and function of a Web-based performance monitoring system.

    PubMed

    Bors, Philip A; Kemner, Allison; Fulton, John; Stachecki, Jessica; Brennan, Laura K

    2015-01-01

    As part of Robert Wood Johnson Foundation's Healthy Kids, Healthy Communities (HKHC) national grant program, a technical assistance team designed the HKHC Community Dashboard, an online progress documentation and networking system. The Dashboard was central to HKHC's multimethod program evaluation and became a communication interface for grantees and technical assistance providers. The Dashboard was designed through an iterative process of identifying needs and priorities; designing the user experience, technical development, and usability testing; and applying visual design. The system was created with an open-source content management system and support for building an online community of users. The site developer trained technical assistance providers at the national program office and evaluators, who subsequently trained all 49 grantees. Evaluators provided support for Dashboard users and populated the site with the bulk of its uploaded tools and resource documents. The system tracked progress through an interactive work plan template, regular documentation by local staff and partners, and data coding and analysis by the evaluation team. Other features included the ability to broadcast information to Dashboard users via e-mail, event calendars, discussion forums, private messaging, a resource clearinghouse, a technical assistance diary, and real-time progress reports. The average number of Dashboard posts was 694 per grantee during the grant period. Technical assistance providers and grantees uploaded a total of 1304 resource documents. The Dashboard functions with the highest grantee satisfaction were its interfaces for sharing and progress documentation. A majority of Dashboard users (69%) indicated a preference for continued access to the Dashboard's uploaded resource documents. The Dashboard was a useful and innovative tool for participatory evaluation of a large national grant program. While progress documentation added some burden to local project staff, the system proved to be a useful resource-sharing technology.

  12. Plug-Assisted Retrograde Transvenous Obliteration for the Treatment of Gastric Varices: The Role of Intra-Procedural Cone-Beam Computed Tomography

    PubMed Central

    Ko, Gi-Young; Kwon, Young Baek; Yoon, Hyun-Ki; Sung, Kyu-Bo

    2018-01-01

    Objective To investigate the technical and clinical outcomes of plug-assisted retrograde transvenous obliteration (PARTO) for the treatment of gastric varices (GV) and to evaluate the role of intra-procedural cone-beam computed tomography (CBCT) performed during PARTO to confirm its technical success. Materials and Methods From January 2016 to December 2016, 17 patients with GV who had undergone PARTO were retrospectively evaluated. When the proximal part of the afferent vein was identified on a fluoroscopy, non-contrast CBCT images were obtained. In patients with incomplete embolization of GV, an additional injection of gelatin sponges was performed. Follow-up data from contrast-enhanced CT and upper intestinal endoscopy, as well as clinical and laboratory data were collected. Results Plug-assisted retrograde transvenous obliteration procedures were technically successful in all 17 patients. Complete embolization of GV was detected on CBCT images in 15 patients; whereas, incomplete embolization was detected in two. Complete embolization of GV was then achieved after an additional injection of gelatin sponges in these two patients as demonstrated on the 2nd CBCT image. The mean follow-up period after PARTO was 193 days (range, 73–383 days). A follow-up CT obtained 2–4 months after PARTO demonstrated marked shrinkage or complete obliteration of GV and portosystemic shunts in all 17 patients. There were no cases of variceal bleeding during the follow-up. Conclusion Plug-assisted retrograde transvenous obliteration is technically and clinically effective for the treatment of GV. In addition, intra-procedural CBCT can be an adjunct tool to fluoroscopy, because it can provide an immediate and accurate evaluation of the technical success of PARTO. PMID:29520179

  13. RL-34 ring laser gyro laboratory evaluation for the Deep Space Network antenna application

    NASA Technical Reports Server (NTRS)

    1991-01-01

    The overall results of this laboratory evaluation are quite encouraging. The gyro data is in good agreement with the system's overall pointing performance, which is quite close to the technical objectives for the Deep Space Network (DSN) application. The system can be calibrated to the levels required for millidegree levels of pointing performance, and initialization performance is within the required 0.001 degree objective. The blind target acquisition performance is within a factor of two of the 0.0001 degree objective, limited only by a combination of the slow rate (0.5 deg/sec) and the existing production quantization logic (0.38 arc-sec/pulse). Logic circuitry exists to better this performance such that it will better the objective by 50 percent. Representative data with this circuitry has been provided for illustration. Target tracking performance is about twice the one millidegree objective, with several factors contributing. The first factor is the bias stability of the gyros, which is exceptional, but will limit performance to the 0.001 and 0.002 degree range for long tracking periods. The second contributing factor is the accelerometer contributions when the system is elevated. These degrade performance into the 0.003 to 0.004 degree range, which could be improved upon with some additional changes. Finally, we have provided a set of recommendations to improve performance closer to the technical objectives. These recommendations include gyro, electronics, and system configurational changes that form the basis for additional work to achieve the desired performance. In conclusion, we believe that the RL-34 ring laser gyro-based advanced navigation system demonstrated performance consistent with expectations and technical objectives, and it has the potential for even further enhancement for the DSN application.

  14. Performance indicators for the efficiency analysis of urban drainage systems.

    PubMed

    Artina, S; Becciu, G; Maglionico, M; Paoletti, A; Sanfilippo, U

    2005-01-01

    Performance indicators implemented in a decision support system (DSS) for the technical, managerial and economic evaluation of urban drainage systems (UDS), called MOMA FD, are presented. Several kinds of information are collected and processed by MOMA FD to evaluate both present situation and future scenarios of development and enhancement. Particular interest is focused on the evaluation of the environmental impact, which is considered a very relevant factor in the decision making process to identify the priorities for UDS improvements.

  15. Fossil Energy Program

    NASA Astrophysics Data System (ADS)

    McNeese, L. E.

    1981-01-01

    Increased utilization of coal and other fossil fuel alternatives as sources of clean energy is reported. The following topics are discussed: coal conversion development, chemical research and development, materials technology, component development and process evaluation studies, technical support to major liquefaction projects, process analysis and engineering evaluations, fossil energy environmental analysis, flue gas desulfurization, solid waste disposal, coal preparation waste utilization, plant control development, atmospheric fluidized bed coal combustor for cogeneration, TVA FBC demonstration plant program technical support, PFBC systems analysis, fossil fuel applications assessments, performance assurance system support for fossil energy projects, international energy technology assessment, and general equilibrium models of liquid and gaseous fuel supplies.

  16. Single plane angiography: Current applications and limitations

    NASA Technical Reports Server (NTRS)

    Falsetti, H. L.; Carroll, R. J.

    1975-01-01

    Technical errors in measurement of one plane cineangiography are identified. Examples of angiographic estimates of left ventricular geometry are given. These estimates of contractility are useful in evaluating myocardial performance.

  17. Serviceable pavement marking retroreflectivity levels : technical report.

    DOT National Transportation Integrated Search

    2009-03-01

    This research addressed an array of issues related to measuring pavement markings retroreflectivity, factors : related to pavement marking performance, subjective evaluation process, best practices for using mobile : retroreflectometers, sampling pav...

  18. 48 CFR 245.603-70 - Contractor performance of plant clearance duties.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Government-furnished property from inventory schedules; (v) Evaluate physical, quantitative, and technical allocability of contractor inventory prior to disposal using Standard Form 1423, Inventory Verification Survey...

  19. The Starlite Project

    DTIC Science & Technology

    1989-10-01

    Operating Systems for Mission-Critical Computing, (Sept. 1989) J1-J7. (12) Son, S. H. and N. Haghighi, "Performance Evaluation of Multiversion Database...Hungary, (Oct. 1989), to appear. (14) Son, S. H. and Y. Kim, "A Software Prototyping Environment and Its Use in Developing a Multiversion Distributed...University of Virginia, (Aug. 1989). (23) Son, S. H. and N. Haghighi, "Performance Evaluation of Multiversion Database Systems," Technical Report IPC

  20. Individual Differences and Learning Performance in Computer-based Training

    DTIC Science & Technology

    2011-02-01

    student outcomes, and early job satisfaction and performance . This report is a selected literature review to provide a starting point from which to...job satisfaction and performance . Initial technical training pipelines will be chosen that vary in length, complexity, and instructional methods (e.g...as job satisfaction , evaluation of authority, citizenship behavior, withdrawal cognitions, and job performance (Colquitt, Conlon, Wesson, Porter

  1. Implementation and evaluation of a dilation and evacuation simulation training curriculum.

    PubMed

    York, Sloane L; McGaghie, William C; Kiley, Jessica; Hammond, Cassing

    2016-06-01

    To evaluate obstetrics and gynecology resident physicians' performance following a simulation curriculum on dilation and evacuation (D&E) procedures. This study included two phases: simulation curriculum development and resident physician performance evaluation following training on a D&E simulator. Trainees participated in two evaluations. Simulation training evaluated participants performing six cases on a D&E simulator, measuring procedural time and a 26-step checklist of D&E steps. The operative training portion evaluated residents' performance after training on the simulator using mastery learning techniques. Intra-operative evaluation was based on a 21-step checklist score, Objective Structured Assessment of Technical Skills (OSATS), and percentage of cases completed. Twenty-two residents participated in simulation training, demonstrating improved performance from cases one and two to cases five and six, as measured by checklist score and procedural time (p<.001 and p=.001, respectively). Of 10 participants in the operative training, all performed at least three D&Es, while seven performed at least six cases. While checklist scores did not change significantly from the first to sixth case (mean for first case: 18.3; for sixth case: 19.6; p=.593), OSATS ratings improved from case one (19.7) to case three (23.5; p=.001) and to case six (26.8; p=.005). Trainees completed approximately 71.6% of their first case (range: 21.4-100%). By case six, the six participants performed 81.2% of the case (range: 14.3-100%). D&E simulation using a newly-developed uterine model and simulation curriculum improves resident technical skills. Simulation training with mastery learning techniques transferred to high level of performance in OR using checklist. The OSATS measured skills and showed improvement in performance with subsequent cases. Implementation of a D&E simulation curriculum offers potential for improved surgical training and abortion provision. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Technical memo, project 0-6132 : task 6, test sections in the districts.

    DOT National Transportation Integrated Search

    2011-05-01

    This Tech Memo presents a summary of the field performance evaluation of the TTI sections in : Laredo District (Webb County) that was conducted at the end of winter on May 3rd 2011; eight : months after HMA overlay placement. Field performance tests ...

  3. Technical memo, project 0-6132 : task 6 - test sections in the districts.

    DOT National Transportation Integrated Search

    2011-05-01

    This Tech Memo presents a summary of the field performance evaluation of the TTI sections in : Laredo District (Webb County) that was conducted at the end of winter on May 3rd 2011; eight : months after HMA overlay placement. Field performance tests ...

  4. 48 CFR 2937.602 - Elements of performance-based contracting.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... objectively measurable incentives (e.g., Firm-Fixed-Price, Fixed-Price-Incentive-Fee, or Cost-Plus-Incentive-Fee) is appropriate. However, when contractor performance (e.g., cost control, schedule, or quality/technical) is best evaluated subjectively using qualitative measures, a Cost-Plus-Award-Fee contract may be...

  5. Non-invasive glucose monitoring in patients with diabetes: a novel system based on impedance spectroscopy.

    PubMed

    Caduff, A; Dewarrat, F; Talary, M; Stalder, G; Heinemann, L; Feldman, Yu

    2006-12-15

    The aim of this work was to evaluate the performance of a novel non-invasive continuous glucose-monitoring system based on impedance spectroscopy (IS) in patients with diabetes. Ten patients with type 1 diabetes (mean+/-S.D., age 28+/-8 years, BMI 24.2+/-3.2 kg/m(2) and HbA(1C) 7.3+/-1.6%) and five with type 2 diabetes (age 61+/-8 years, BMI 27.5+/-3.2 kg/m(2) and HbA(1C) 8.3+/-1.8%) took part in this study, which comprised a glucose clamp experiment followed by a 7-day outpatient evaluation. The measurements obtained by the NI-CGMD and the reference blood glucose-measuring techniques were evaluated using retrospective data evaluation procedures. Under less controlled outpatient conditions a correlation coefficient of r=0.640 and a standard error of prediction (SEP) of 45 mg dl(-1) with a total of 590 paired glucose measurements was found (versus r=0.926 and a SEP of 26 mg dl(-1) under controlled conditions). Clark error grid analyses (EGA) showed 56% of all values in zone A, 37% in B and 7% in C-E. In conclusion, these results indicate that IS in the used technical setting allows retrospective, continuous and truly non-invasive glucose monitoring under defined conditions for patients with diabetes. Technical advances and developments are needed to expand on this concept to bring the results from the outpatient study closer to those in the experimental section of the study. Further studies will not only help to evaluate the performance and limitations of using such a technique for non non-invasive glucose monitoring but also help to verify technical extensions towards a IS-based concept that offers improved performance under real life operating conditions.

  6. Voluntary medical male circumcision scale-up in Nyanza, Kenya: evaluating technical efficiency and productivity of service delivery.

    PubMed

    Omondi Aduda, Dickens S; Ouma, Collins; Onyango, Rosebella; Onyango, Mathews; Bertrand, Jane

    2015-01-01

    Voluntary medical male circumcision (VMMC) service delivery is complex and resource-intensive. In Kenya's context there is still paucity of information on resource use vis-à-vis outputs as programs scale up. Knowledge of technical efficiency, productivity and potential sources of constraints is desirable to improve decision-making. To evaluate technical efficiency and productivity of VMMC service delivery in Nyanza in 2011/2012 using data envelopment analysis. Comparative process evaluation of facilities providing VMMC in Nyanza in 2011/2012 using output orientated data envelopment analysis. Twenty one facilities were evaluated. Only 1 of 7 variables considered (total elapsed operation time) significantly improved from 32.8 minutes (SD 8.8) in 2011 to 30 minutes (SD 6.6) in 2012 (95%CI = 0.0350-5.2488; p = 0.047). Mean scale technical efficiency significantly improved from 91% (SD 19.8) in 2011 to 99% (SD 4.0) in 2012 particularly among outreach compared to fixed service delivery facilities (CI -31.47959-4.698508; p = 0.005). Increase in mean VRS technical efficiency from 84% (SD 25.3) in 2011 and 89% (SD 25.1) in 2012 was not statistically significant. Benchmark facilities were #119 and #125 in 2011 and #103 in 2012. Malmquist Productivity Index (MPI) at fixed facilities declined by 2.5% but gained by 4.9% at outreach ones by 2012. Total factor productivity improved by 83% (p = 0.032) in 2012, largely due to progress in technological efficiency by 79% (p = 0.008). Significant improvement in scale technical efficiency among outreach facilities in 2012 was attributable to accelerated activities. However, ongoing pure technical inefficiency requires concerted attention. Technological progress was the key driver of service productivity growth in Nyanza. Incorporating service-quality dimensions and using stepwise-multiple criteria in performance evaluation enhances comprehensiveness and validity. These findings highlight site-level resource use and sources of variations in VMMC service productivity, which are important for program planning.

  7. Evaluation of nature-like and technical fishways for the passage of alewives at two coastal streams in New England

    USGS Publications Warehouse

    Franklin, Abigail E.; Haro, Alex; Castro-Santos, Theodore; Noreika, John

    2012-01-01

    Nature-like fishways have been designed with the intent to reconnect river corridors and provide passage for all species occurring in a system. The approach is gaining popularity both in Europe and North America, but performance of these designs has not been quantitatively evaluated in a field setting for any North American species. Two nature-like fishways and three technical fishways in New England were evaluated for passage of anadromous adult alewives Alosa pseudoharengus by using passive integrated transponder (PIT) telemetry. A perturbation boulder rock ramp (32 m long; 4.2% slope) constructed in Town Brook (Plymouth, Massachusetts) passed 94% of the fish that made passage attempts, with most fish ascending the ramp in less than 22 min. In the East River (Guilford, Connecticut), a step-pool bypass design (48 m long; 7.1% slope) passed only 40% of attempting fish, with a median transit time of 75 min. In Town Brook, a technical pool-and-weir fishway (14 m long; 14.3% slope) exhibited poor entry and poor passage for the fish. In contrast, in the East River, two technical steeppass fishways (3 m long; 29.6% and 9.6% slopes) passed the majority of available fish, although one of these steeppass fishways may have lacked sufficient flow to attract fish to the entrance. In both Town Brook and the East River, tagged fish passed rapidly downstream through all fishways after spawning. In the East River, the amount of time fish spent in the spawning habitat before migrating downstream ranged from 1 to 41 d. These studies demonstrate that some nature-like and technical fishway designs can effectively facilitate passage of alewives, but a fishway's location in relation to a spillway is important, and further evaluations are required to more precisely identify the influence of the vertical drop per pool and the specific local hydraulics on alewife behaviors and passage performance.

  8. Technical Report for Calculations of Atmospheric Dispersion at Onsite Locations for Department of Energy Nuclear Facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Levin, Alan; Chaves, Chris

    2015-04-04

    The Department of Energy (DOE) has performed an evaluation of the technical bases for the default value for the atmospheric dispersion parameter χ/Q. This parameter appears in the calculation of radiological dose at the onsite receptor location (co-located worker at 100 meters) in safety analysis of DOE nuclear facilities. The results of the calculation are then used to determine whether safety significant engineered controls should be established to prevent and/or mitigate the event causing the release of hazardous material. An evaluation of methods for calculation of the dispersion of potential chemical releases for the purpose of estimating the chemical exposuremore » at the co-located worker location was also performed. DOE’s evaluation consisted of: (a) a review of the regulatory basis for the default χ/Q dispersion parameter; (b) an analysis of this parameter’s sensitivity to various factors that affect the dispersion of radioactive material; and (c) performance of additional independent calculations to assess the appropriate use of the default χ/Q value.« less

  9. The acceptability of TV-based game platforms as an instrument to support the cognitive evaluation of senior adults at home.

    PubMed

    Rivas Costa, Carlos; Fernández Iglesias, Manuel José; Anido Rifón, Luis Eulogio; Gómez Carballa, Miguel; Valladares Rodríguez, Sonia

    2017-01-01

    The computing capabilities of state-of-the-art television sets and media centres may facilitate the introduction of computer-assisted evaluation at home. This approach would help to overcome the drawbacks of traditional pen-and-paper evaluations administered in clinical facilities, as they could be performed in a more comfortable environment, the subject's home, and they would be more flexible for designing complex environments for the evaluation of neuropsychological constructs that are difficult to assess through traditional testing. The objective of this work was to obtain some initial evidence about the technical acceptance by senior adults of serious games played at home on the TV set and therefore about the convenience of further investigating such an approach to cognitive assesment. We developed a collection of games to be deployed on a TV environment. These games were tried by a group of senior adults at their homes. The Technology Acceptance Model (TAM) was used to validate this approach. Surveys were performed to study the perceived usefulness and perceived ease of use of such technical setting as an instrument for their cognitive evaluation; that is, its technical acceptance. Subjective information collected from participants was correlated with actual interaction data captured. An additional survey was performed 36 months after pilot testing to have an indication about the long-term perceptions about usefulness and ease of use. More than 90% of participating subjects perceived cognitive games on TV as useful or very useful. The majority of participants selected the TV set as their preferred option to interact with serious games at home, when compared to other devices such as smartphones, tablets or PCs. This result correlates with the number of participants perceiving them as easily usable or very easy to use, and also with automatically captured interaction data. Three out of four seniors expressed their interest in keeping the system at home after the pilot. Besides, these perceptions are fairly stable in time as shown by the survey performed 36 months after pilot testing. Although participating users are a representative sample of the Galician population, which in turn is comparable to the population of most rural areas in Europe, a larger and more diverse user sample would be needed to obtain significant results for a wider population profile. The study confirmed the technical acceptance, that is, the perceived usefulness and perceived ease of use, of the TV-based home technical setting introduced as a means of cognitive evaluation. This study provides initial evidence on the viability of a TV-based serious games approach for cognitive longitudinal screening at home with little intervention of clinical professionals, thus contributing to the early detection of cognitive impairments in the senior population.

  10. Evaluation results of xTCA equipment for HEP experiments at CERN

    NASA Astrophysics Data System (ADS)

    Di Cosmo, M.; Bobillier, V.; Haas, S.; Joos, M.; Mico, S.; Vasey, F.; Vichoudis, P.

    2013-12-01

    The MicroTCA and AdvancedTCA industry standards are candidate modular electronic platforms for the upgrade of the current generation of high energy physics experiments. The PH-ESE group at CERN launched in 2011 the xTCA evaluation project with the aim of performing technical evaluations and eventually providing support for commercially available components. Different devices from different vendors have been acquired, evaluated and interoperability tests have been performed. This paper presents the test procedures and facilities that have been developed and focuses on the evaluation results including electrical, thermal and interoperability aspects.

  11. Strategies for increasing the feasibility of performance assessments during competency-based education: Subjective and objective evaluations correlate in the operating room.

    PubMed

    Szasz, Peter; Louridas, Marisa; Harris, Kenneth A; Grantcharov, Teodor P

    2017-08-01

    Competency-based education necessitates assessments that determine whether trainees have acquired specific competencies. The evidence on the ability of internal raters (staff surgeons) to provide accurate assessments is mixed; however, this has not yet been directly explored in the operating room. This study's objective is to compare the ratings given by internal raters vs an expert external rater (independent to the training process) in the operating room. Raters assessed general surgery residents during a laparoscopic cholecystectomy for their technical and nontechnical performance. Fifteen cases were observed. There was a moderately positive correlation (r s = .618, P = .014) for technical performance and a strong positive correlation (r s = .731, P = .002) for nontechnical performance. The internal raters were less stringent for technical (mean rank 3.33 vs 8.64, P = .007) and nontechnical (mean rank 3.83 vs 8.50, P = .01) performances. This study provides evidence to help operationalize competency-based assessments. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. What Today's Educational Technology Needs: Defensible Evaluations and Realistic Implementation.

    ERIC Educational Resources Information Center

    Roweton, William E.; And Others

    It is argued that in order to make computer assisted instruction effective in the schools, educators should pay more attention to implementation issues (including modifying teacher attitudes, changing classroom routines, and offering realistic technical training and support) and to producing understandable product and performance evaluations.…

  13. Performance Evaluation of the United Nations Environment Programme Air Quality Monitoring Unit

    EPA Science Inventory

    A request for technical collaboration between the UNEP and the US EPA resulted in the establishment of a MCRADA. The purpose of this agreement was to evaluate an air quality monitoring system (referred to as the UNEP pod) developed by the UNEP for use in environmental situations ...

  14. Evaluating Indicators and Life Cycle Inventories for Processes in Early Stages of Technical Readiness

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tan, Eric C; Smith, Raymond; Ruiz-Mercado, Gerardo

    This presentation examines different methods for analyzing manufacturing processes in the early stages of technical readiness. Before developers know much detail about their processes, it is valuable to apply various assessments to evaluate their performance. One type of assessment evaluates performance indicators to describe how closely processes approach desirable objectives. Another type of assessment determines the life cycle inventories (LCI) of inputs and outputs for processes, where for a functional unit of product, the user evaluates the resources used and the releases to the environment. These results can be compared to similar processes or combined with the LCI of othermore » processes to examine up-and down-stream chemicals. The inventory also provides a listing of the up-stream chemicals, which permits study of the whole life cycle. Performance indicators are evaluated in this presentation with the U.S. Environmental Protection Agency's GREENSCOPE (Gauging Reaction Effectiveness for ENvironmental Sustainability with a multi-Objective Process Evaluator) methodology, which evaluates processes in four areas: Environment, Energy, Economics, and Efficiency. The method develops relative scores for indicators that allow comparisons across various technologies. In this contribution, two conversion pathways for producing cellulosic ethanol from biomass, via thermochemical and biochemical routes, are studied. The information developed from the indicators and LCI can be used to inform the process design and the potential life cycle effects of up- and down-stream chemicals.« less

  15. Trainees' perceptions of practitioner competence during patient transfer.

    PubMed

    Grierson, Lawrence; Dubrowski, Adam; So, Steph; Kistner, Nicole; Carnahan, Heather

    2012-01-01

    Technical and communicative skills are both important features for one's perception of practitioner competence. This research examines how trainees' perceptions of practitioner competence change as they view health care practitioners who vary in their technical and communicative skill proficiencies. Occupational therapy students watched standardized encounters of a practitioner performing a patient transfer in combinations of low and high technical and communicative proficiency and then reported their perceptions of practitioner competence. The reports indicate that technical and communicative skills have independently identifiable impacts on the perceptions of practitioner competency, but technical proficiency has a special impact on the students' perceptions of practitioner communicative competence. The results are discussed with respect to the way in which students may evaluate their own competence on the basis of either technical or communicative skill. The issue of how this may lead trainees to dedicate their independent learning efforts to an incomplete set of features needed for the development of practitioner competency is raised.

  16. A Comparative Assessment of the Performance of Select Higher Education Institutes in India

    ERIC Educational Resources Information Center

    Sahney, Sangeeta; Thakkar, Jitesh

    2016-01-01

    Purpose: The purpose of this paper is to evaluate the performance of select technical higher education institutes of national importance in India. This helps to judge the efficiency and effectiveness of an institute to provide valuable insights on performance measurement and effectiveness not only to the respective institute but also to…

  17. Evaluating Environmental Effects of Dredged Material Management Alternatives - A Technical Framework. Revision

    DTIC Science & Technology

    2004-05-01

    Significant Impact HELPQ - Hydrologic Evaluation of Leachate Production and Quality HELP - Hydrologic Evaluation of Landfill Performance LDC...BIOASSAY SURFACE RUNOFF CONTROLS • PONDING • TREATMENT • OTHERS (5.3.6) AND EVALUATE AND /OR GROUNDWATER /OR LEACHATE • • • LEACHATE TESTING... LEACHATE CONTROLS COVERS LINERS TREATMENT PLANT BIOASSAY PLANT UPTAKE CONTROLS • COVERS • SELECTIVE VEGETATION (5.1) (5.2) (5.3

  18. Impact of IQ, computer-gaming skills, general dexterity, and laparoscopic experience on performance with the da Vinci surgical system.

    PubMed

    Hagen, Monika E; Wagner, Oliver J; Inan, Ihsan; Morel, Philippe

    2009-09-01

    Due to improved ergonomics and dexterity, robotic surgery is promoted as being easily performed by surgeons with no special skills necessary. We tested this hypothesis by measuring IQ elements, computer gaming skills, general dexterity with chopsticks, and evaluating laparoscopic experience in correlation to performance ability with the da Vinci robot. Thirty-four individuals were tested for robotic dexterity, IQ elements, computer-gaming skills and general dexterity. Eighteen surgically inexperienced and 16 laparoscopically trained surgeons were included. Each individual performed three different tasks with the da Vinci surgical system and their times were recorded. An IQ test (elements: logical thinking, 3D imagination and technical understanding) was completed by each participant. Computer skills were tested with a simple computer game (hand-eye coordination) and general dexterity was evaluated by the ability to use chopsticks. We found no correlation between logical thinking, 3D imagination and robotic skills. Both computer gaming and general dexterity showed a slight but non-significant improvement in performance with the da Vinci robot (p > 0.05). A significant correlation between robotic skills, technical understanding and laparoscopic experience was observed (p < 0.05). The data support the conclusion that there are no significant correlations between robotic performance and logical thinking, 3D understanding, computer gaming skills and general dexterity. A correlation between robotic skills and technical understanding may exist. Laparoscopic experience seems to be the strongest predictor of performance with the da Vinci surgical system. Generally, it appears difficult to determine non-surgical predictors for robotic surgery.

  19. Technical Criteria and Procedures for Evaluating the Crashworthiness and Occupant Protection Performance of Alternatively Designed Passenger Rail Equipment for Use in Tier I Service

    DOT National Transportation Integrated Search

    2011-10-01

    Criteria and procedures have been developed for assessing crashworthiness and occupant protection performance of alternatively designed trainsets to be used in Tier I (not exceeding 125 mph) passenger service. These criteria and procedures take advan...

  20. Solar energy system performance evaluation report for IBM System 3, Glendo, Wyoming

    NASA Technical Reports Server (NTRS)

    1980-01-01

    The analysis used was based on instrumented system data monitored and collected for at least one full season of operation. The long-term field performance of the installed system is described. Technical contributions to the definition of techniques and requirements for solar energy system design are given.

  1. 48 CFR 1352.213-70 - Evaluation utilizing simplified acquisition procedures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... perform their proposed duties. (2) Technical Approach and Capability. The offeror's approach to performing...) The Government will issue an order resulting from this request for quotation to the responsible offeror whose quotation results in the best value to the Government, considering both price and non-price...

  2. Technical memo, project 0-6132 : task 6 - test sections in the districts.

    DOT National Transportation Integrated Search

    2011-05-01

    This Tech Memo presents a summary of the field performance evaluation of the TTI sections on US 59 in Panola County (Atlanta District) that was conducted at the end of winter on May 13th 2011; one year after HMA overlay placement. Field performance t...

  3. Surgical resident technical skill self-evaluation: increased precision with training progression.

    PubMed

    Quick, Jacob A; Kudav, Vishal; Doty, Jennifer; Crane, Megan; Bukoski, Alex D; Bennett, Bethany J; Barnes, Stephen L

    2017-10-01

    Surgical resident ability to accurately evaluate one's own skill level is an important part of educational growth. We aimed to determine if differences exist between self and observer technical skill evaluation of surgical residents performing a single procedure. We prospectively enrolled 14 categorical general surgery residents (six post-graduate year [PGY] 1-2, three PGY 3, and five PGY 4-5). Over a 6-month period, following each laparoscopic cholecystectomy, residents and seven faculty each completed the Objective Structured Assessment of Technical Skills (OSATS). Spearman's coefficient was calculated for three groups: senior (PGY 4-5), PGY3, and junior (PGY 1-2). Rho (ρ) values greater than 0.8 were considered well correlated. Of the 125 paired assessments (resident-faculty each evaluating the same case), 58 were completed for senior residents, 54 for PGY3 residents, and 13 for junior residents. Using the mean from all OSATS categories, trainee self-evaluations correlated well to faculty (senior ρ 0.97, PGY3 ρ 0.9, junior ρ 0.9). When specific OSATS categories were analyzed, junior residents exhibited poor correlation in categories of respect for tissue (ρ -0.5), instrument handling (ρ 0.71), operative flow (ρ 0.41), use of assistants (ρ 0.05), procedural knowledge (ρ 0.32), and overall comfort with the procedure (ρ 0.73). PGY3 residents lacked correlation in two OSATS categories, operative flow (ρ 0.7) and procedural knowledge (ρ 0.2). Senior resident self-evaluations exhibited strong correlations to observers in all areas. Surgical residents improve technical skill self-awareness with progressive training. Less-experienced trainees have a tendency to over-or-underestimate technical skill. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. A Human Factors Analysis of Technical and Team Skills Among Surgical Trainees During Procedural Simulations in a Simulated Operating Theatre

    PubMed Central

    Moorthy, Krishna; Munz, Yaron; Adams, Sally; Pandey, Vikas; Darzi, Ara

    2005-01-01

    Background: High-risk organizations such as aviation rely on simulations for the training and assessment of technical and team performance. The aim of this study was to develop a simulated environment for surgical trainees using similar principles. Methods: A total of 27 surgical trainees carried out a simulated procedure in a Simulated Operating Theatre with a standardized OR team. Observation of OR events was carried out by an unobtrusive data collection system: clinical data recorder. Assessment of performance consisted of blinded rating of technical skills, a checklist of technical events, an assessment of communication, and a global rating of team skills by a human factors expert and trained surgical research fellows. The participants underwent a debriefing session, and the face validity of the simulated environment was evaluated. Results: While technical skills rating discriminated between surgeons according to experience (P = 0.002), there were no differences in terms of the checklist and team skills (P = 0.70). While all trainees were observed to gown/glove and handle sharps correctly, low scores were observed for some key features of communication with other team members. Low scores were obtained by the entire cohort for vigilance. Interobserver reliability was 0.90 and 0.89 for technical and team skills ratings. Conclusions: The simulated operating theatre could serve as an environment for the development of surgical competence among surgical trainees. Objective, structured, and multimodal assessment of performance during simulated procedures could serve as a basis for focused feedback during training of technical and team skills. PMID:16244534

  5. Energy retrofit of an office building by substitution of the generation system: performance evaluation via dynamic simulation versus current technical standards

    NASA Astrophysics Data System (ADS)

    Testi, D.; Schito, E.; Menchetti, E.; Grassi, W.

    2014-11-01

    Constructions built in Italy before 1945 (about 30% of the total built stock) feature low energy efficiency. Retrofit actions in this field can lead to valuable energetic and economic savings. In this work, we ran a dynamic simulation of a historical building of the University of Pisa during the heating season. We firstly evaluated the energy requirements of the building and the performance of the existing natural gas boiler, validated with past billings of natural gas. We also verified the energetic savings obtainable by the substitution of the boiler with an air-to-water electrically-driven modulating heat pump, simulated through a cycle-based model, evaluating the main economic metrics. The cycle-based model of the heat pump, validated with manufacturers' data available only at specified temperature and load conditions, can provide more accurate results than the simplified models adopted by current technical standards, thus increasing the effectiveness of energy audits.

  6. Bench model surgical skill training improves novice ability to multitask: a randomized controlled study.

    PubMed

    Grierson, Lawrence; Melnyk, Megan; Jowlett, Nathan; Backstein, David; Dubrowski, Adam

    2011-01-01

    Skills training in simulation laboratories is becoming increasingly common. However, the educational benefit of these laboratories remains unclear. This study examined whether such training enables better performance on the simultaneous execution of technical skill and knowledge retention. Twenty-four novice trainees completed the elliptical excision on baseline testing. Following baseline testing twelve of the novices completed a technical practice (simulation training group) session, while the other twelve did not (control group). One week later, all participants returned for dual-task follow up testing in which they performed the excision while listening to a didactic lesson on the staging and treatment of cutaneous melanoma. The dual-tasking during the post test was standardized, whereby excision sutures 3 and 5 were performed alone (single), and sutures 4 and 6 were performed concurrently with the didactic lecture (dual). Seven additional trainees also participated as controls that were randomized to listen to the didactic lesson alone (knowledge retention alone group). Knowledge retention was assessed by a multiple choice questionnaire (MCQ). Technical performance was evaluated with computer and expert-based measures. Time to complete the performance improved among both groups completing the elliptical excision on follow-up testing (p<0.01). The simulation training group demonstrated superior hand motion performance on simultaneous didactic lesson testing (p<0.01). Novices from the no-training group performed statistically worse while suturing concurrently with the didactic lesson (p<0.01). The pretraining of novices in surgical skills laboratories leads to improved technical performance during periods of increased attention demands.

  7. Crowd-sourced assessment of technical skills: an adjunct to urology resident surgical simulation training.

    PubMed

    Holst, Daniel; Kowalewski, Timothy M; White, Lee W; Brand, Timothy C; Harper, Jonathan D; Sorenson, Mathew D; Kirsch, Sarah; Lendvay, Thomas S

    2015-05-01

    Crowdsourcing is the practice of obtaining services from a large group of people, typically an online community. Validated methods of evaluating surgical video are time-intensive, expensive, and involve participation of multiple expert surgeons. We sought to obtain valid performance scores of urologic trainees and faculty on a dry-laboratory robotic surgery task module by using crowdsourcing through a web-based grading tool called Crowd Sourced Assessment of Technical Skill (CSATS). IRB approval was granted to test the technical skills grading accuracy of Amazon.com Mechanical Turk™ crowd-workers compared to three expert faculty surgeon graders. The two groups assessed dry-laboratory robotic surgical suturing performances of three urology residents (PGY-2, -4, -5) and two faculty using three performance domains from the validated Global Evaluative Assessment of Robotic Skills assessment tool. After an average of 2 hours 50 minutes, each of the five videos received 50 crowd-worker assessments. The inter-rater reliability (IRR) between the surgeons and crowd was 0.91 using Cronbach's alpha statistic (confidence intervals=0.20-0.92), indicating an agreement level between the two groups of "excellent." The crowds were able to discriminate the surgical level, and both the crowds and the expert faculty surgeon graders scored one senior trainee's performance above a faculty's performance. Surgery-naive crowd-workers can rapidly assess varying levels of surgical skill accurately relative to a panel of faculty raters. The crowds provided rapid feedback and were inexpensive. CSATS may be a valuable adjunct to surgical simulation training as requirements for more granular and iterative performance tracking of trainees become mandated and commonplace.

  8. Do Low-Income Students Have Equal Access to the Highest-Performing Teachers? Technical Appendix. NCEE 2011-4016

    ERIC Educational Resources Information Center

    Glazerman, Steven; Max, Jeffrey

    2011-01-01

    This appendix describes the methods and provides further detail to support the evaluation brief, "Do Low-Income Students Have Equal Access to the Highest-Performing Teachers?" (Contains 8 figures, 6 tables and 5 footnotes.) [For the main report, "Do Low-Income Students Have Equal Access to the Highest-Performing Teachers? NCEE…

  9. Applied Workplace Literacy for the Facilities Maintenance Industry. Performance Report and Third Party Evaluation Report.

    ERIC Educational Resources Information Center

    Texas State Technical Coll., Waco.

    A project was conducted to determine if interactive video programs could produce positive results in literacy programs. During the project, staff from a technical college developed a task analysis, curriculum, and evaluation measures for the training of facilities maintenance workers in mathematical concepts. From this activity, an instructional…

  10. FloorPlan. Courseware Evaluation for Vocational and Technical Education.

    ERIC Educational Resources Information Center

    Rosenfeld, Vila M.; And Others

    This courseware evaluation rates the "FloorPlan" program developed by the Learning Seed. (The program--not included in this document--allows room design and arrangement to be performed on the computer screen.) The courseware was rated by a team of home economists participating in a network for the dissemination of courseware reviews.…

  11. Woody biomass pretreatment for cellulosic ethanol production : technology and energy consumption evaluation

    Treesearch

    Junyong Zhu; X.J. Pan

    2010-01-01

    This review presents a comprehensive discussion of the key technical issues in woody biomass pretreatment: barriers to efficient cellulose saccharification, pretreatment energy consumption, in particular energy consumed for wood-size reduction, and criteria to evaluate the performance of a pretreatment. A post-chemical pretreatment size-reduction approach is proposed...

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anastasia M. Gribik; Ronald E. Mizia; Harry Gatley

    This project addresses both the technical and economic feasibility of replacing industrial gas in lime kilns with synthesis gas from the gasification of hog fuel. The technical assessment includes a materials evaluation, processing equipment needs, and suitability of the heat content of the synthesis gas as a replacement for industrial gas. The economic assessment includes estimations for capital, construction, operating, maintenance, and management costs for the reference plant. To perform these assessments, detailed models of the gasification and lime kiln processes were developed using Aspen Plus. The material and energy balance outputs from the Aspen Plus model were used asmore » inputs to both the material and economic evaluations.« less

  13. Technical and Energy Performance of an Advanced, Aqueous Ammonia-Based CO2 Capture Technology for a 500 MW Coal-Fired Power Station.

    PubMed

    Li, Kangkang; Yu, Hai; Feron, Paul; Tade, Moses; Wardhaugh, Leigh

    2015-08-18

    Using a rate-based model, we assessed the technical feasibility and energy performance of an advanced aqueous-ammonia-based postcombustion capture process integrated with a coal-fired power station. The capture process consists of three identical process trains in parallel, each containing a CO2 capture unit, an NH3 recycling unit, a water separation unit, and a CO2 compressor. A sensitivity study of important parameters, such as NH3 concentration, lean CO2 loading, and stripper pressure, was performed to minimize the energy consumption involved in the CO2 capture process. Process modifications of the rich-split process and the interheating process were investigated to further reduce the solvent regeneration energy. The integrated capture system was then evaluated in terms of the mass balance and the energy consumption of each unit. The results show that our advanced ammonia process is technically feasible and energy-competitive, with a low net power-plant efficiency penalty of 7.7%.

  14. Warm/cold cloud processes

    NASA Technical Reports Server (NTRS)

    Davis, M. H.

    1981-01-01

    Final development of a gravimetric test for performance evaluation of a precision saturator is described. The design and development of a prototype droplet levitation chamber is discussed. Technical assistance to the MSFC Airborne Laser Doppler Program is reported.

  15. 77 FR 75173 - Comprehensive Assessment of the Process for the Review of Device Submissions; Request for Comments

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-19

    ... performing the technical analysis, management assessment, and program evaluation tasks required to address... premarket reviews that meet regulatory review standards. 2. Analysis of elements of the review process... process. This includes analysis of root causes for inefficiencies that may affect review performance and...

  16. The Use of Minimum Objectives in Curriculum Research and Development, 1975-1976. Technical Report #45.

    ERIC Educational Resources Information Center

    Crowell, Doris

    This report describes a curriculum, based on stated performance objectives, which was developed and implemented by the Kamehameha Early Education Program (KEEP). The structure of the mathematics and reading curriculum is described briefly and the use of performance objectives in evaluating student progress is discussed. Advantages of the…

  17. Enhancement of the Probabilistic CEramic Matrix Composite ANalyzer (PCEMCAN) Computer Code

    NASA Technical Reports Server (NTRS)

    Shah, Ashwin

    2000-01-01

    This report represents a final technical report for Order No. C-78019-J entitled "Enhancement of the Probabilistic Ceramic Matrix Composite Analyzer (PCEMCAN) Computer Code." The scope of the enhancement relates to including the probabilistic evaluation of the D-Matrix terms in MAT2 and MAT9 material properties card (available in CEMCAN code) for the MSC/NASTRAN. Technical activities performed during the time period of June 1, 1999 through September 3, 1999 have been summarized, and the final version of the enhanced PCEMCAN code and revisions to the User's Manual is delivered along with. Discussions related to the performed activities were made to the NASA Project Manager during the performance period. The enhanced capabilities have been demonstrated using sample problems.

  18. Final Assessment of Manual Ultrasonic Examinations Applied to Detect Flaws in Primary System Dissimilar Metal Welds at North Anna Power Station

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, Michael T.; Diaz, Aaron A.; Cinson, Anthony D.

    2014-03-24

    PNNL conducted a technical assessment of the NDE issues and protocols that led to missed detections of several axially oriented flaws in a steam generator primary inlet dissimilar metal weld at North Anna Power Station, Unit 1 (NAPS-1). This particular component design exhibits a significant outside-diameter (OD) taper that is not included as a blind performance demonstration mock-up within the industry’s Performance Demonstration Initiative, administered by EPRI. For this reason, the licensee engaged EPRI to assist in the development of a technical justification to support the basis for a site-specific qualification. The service-induced flaws at NAPS-1 were eventually detected asmore » a result of OD surface machining in preparation for a full structural weld overlay. The machining operation uncovered the existence of two through-wall flaws, based on the observance of primary water leaking from the dissimilar metal weld. A total of five axially oriented flaws were detected in varied locations around the weld circumference. The field volumetric examination that was conducted at NAPS-1 was a non-encoded, real-time manual ultrasonic examination. PNNL conducted both an initial assessment, and subsequently, a more rigorous technical evaluation (reported here), which has identified an array of NDE issues that may have led to the subject missed detections. These evaluations were performed through technical reviews and discussions with NRC staff, EPRI NDE Center personnel, industry and ISI vendor personnel, and ultrasonic transducer manufacturers, and laboratory tests, to better understand the underlying issues at North Anna.« less

  19. Evaluation of the Transcribed Weather Broadcast (TWEB) System and Alternatives. Volume I. Technical and Operational Assessment and Cost Summary.

    DTIC Science & Technology

    1980-08-01

    objectives of this project were to perform an evaluation of the effectiveness of the Transcribed Weather Broadcast (TWEB) System in its current national con... performance of TWEB at selected represent- ative field locations. In addition, discussions concerning the review and appraisal of TWEB and Pilots...Briefing Surface TELCO Telephone Company TEL-TWZB telephone access to TWEB TV television TWEB Transcribed Weather Broadcast UNICOM Aeronautical Advisory

  20. Reliable assessment of laparoscopic performance in the operating room using videotape analysis.

    PubMed

    Chang, Lily; Hogle, Nancy J; Moore, Brianna B; Graham, Mark J; Sinanan, Mika N; Bailey, Robert; Fowler, Dennis L

    2007-06-01

    The Global Operative Assessment of Laparoscopic Skills (GOALS) is a valid assessment tool for objectively evaluating the technical performance of laparoscopic skills in surgery residents. We hypothesized that GOALS would reliably differentiate between an experienced (expert) and an inexperienced (novice) laparoscopic surgeon (construct validity) based on a blinded videotape review of a laparoscopic cholecystectomy procedure. Ten board-certified surgeons actively engaged in the practice and teaching of laparoscopy reviewed and evaluated the videotaped operative performance of one novice and one expert laparoscopic surgeon using GOALS. Each reviewer recorded a score for both the expert and the novice videotape reviews in each of the 5 domains in GOALS (depth perception, bimanual dexterity, efficiency, tissue handling, and overall competence). The scores for the expert and the novice were compared and statistically analyzed using single-factor analysis of variance (ANOVA). The expert scored significantly higher than the novice did in the domains of depth perception (p = .005), bimanual dexterity (p = .001), efficiency (p = .001), and overall competence ( p = .001). Interrater reliability for the reviewers of the novice tape was Cronbach alpha = .93 and the expert tape was Cronbach alpha = .87. There was no difference between the two for tissue handling. The Global Operative Assessment of Laparoscopic Skills is a valid, objective assessment tool for evaluating technical surgical performance when used to blindly evaluate an intraoperative videotape recording of a laparoscopic procedure.

  1. Virtual reality training for improving the skills needed for performing surgery of the ear, nose or throat.

    PubMed

    Piromchai, Patorn; Avery, Alex; Laopaiboon, Malinee; Kennedy, Gregor; O'Leary, Stephen

    2015-09-09

    Virtual reality simulation uses computer-generated imagery to present a simulated training environment for learners. This review seeks to examine whether there is evidence to support the introduction of virtual reality surgical simulation into ear, nose and throat surgical training programmes. 1. To assess whether surgeons undertaking virtual reality simulation-based training achieve surgical ('patient') outcomes that are at least as good as, or better than, those achieved through conventional training methods.2. To assess whether there is evidence from either the operating theatre, or from controlled (simulation centre-based) environments, that virtual reality-based surgical training leads to surgical skills that are comparable to, or better than, those achieved through conventional training. The Cochrane Ear, Nose and Throat Disorders Group (CENTDG) Trials Search Co-ordinator searched the CENTDG Trials Register; Central Register of Controlled Trials (CENTRAL 2015, Issue 6); PubMed; EMBASE; ERIC; CINAHL; Web of Science; ClinicalTrials.gov; ICTRP and additional sources for published and unpublished trials. The date of the search was 27 July 2015. We included all randomised controlled trials and controlled trials comparing virtual reality training and any other method of training in ear, nose or throat surgery. We used the standard methodological procedures expected by The Cochrane Collaboration. We evaluated both technical and non-technical aspects of skill competency. We included nine studies involving 210 participants. Out of these, four studies (involving 61 residents) assessed technical skills in the operating theatre (primary outcomes). Five studies (comprising 149 residents and medical students) assessed technical skills in controlled environments (secondary outcomes). The majority of the trials were at high risk of bias. We assessed the GRADE quality of evidence for most outcomes across studies as 'low'. Operating theatre environment (primary outcomes) In the operating theatre, there were no studies that examined two of three primary outcomes: real world patient outcomes and acquisition of non-technical skills. The third primary outcome (technical skills in the operating theatre) was evaluated in two studies comparing virtual reality endoscopic sinus surgery training with conventional training. In one study, psychomotor skill (which relates to operative technique or the physical co-ordination associated with instrument handling) was assessed on a 10-point scale. A second study evaluated the procedural outcome of time-on-task. The virtual reality group performance was significantly better, with a better psychomotor score (mean difference (MD) 1.66, 95% CI 0.52 to 2.81; 10-point scale) and a shorter time taken to complete the operation (MD -5.50 minutes, 95% CI -9.97 to -1.03). Controlled training environments (secondary outcomes) In a controlled environment five studies evaluated the technical skills of surgical trainees (one study) and medical students (three studies). One study was excluded from the analysis. Surgical trainees: One study (80 participants) evaluated the technical performance of surgical trainees during temporal bone surgery, where the outcome was the quality of the final dissection. There was no difference in the end-product scores between virtual reality and cadaveric temporal bone training. Medical students: Two other studies (40 participants) evaluated technical skills achieved by medical students in the temporal bone laboratory. Learners' knowledge of the flow of the operative procedure (procedural score) was better after virtual reality than conventional training (SMD 1.11, 95% CI 0.44 to 1.79). There was also a significant difference in end-product score between the virtual reality and conventional training groups (SMD 2.60, 95% CI 1.71 to 3.49). One study (17 participants) revealed that medical students acquired anatomical knowledge (on a scale of 0 to 10) better during virtual reality than during conventional training (MD 4.3, 95% CI 2.05 to 6.55). No studies in a controlled training environment assessed non-technical skills. There is limited evidence to support the inclusion of virtual reality surgical simulation into surgical training programmes, on the basis that it can allow trainees to develop technical skills that are at least as good as those achieved through conventional training. Further investigations are required to determine whether virtual reality training is associated with better real world outcomes for patients and the development of non-technical skills. Virtual reality simulation may be considered as an additional learning tool for medical students.

  2. Process Hood Stand Support Steel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    VAN KATWIJK, C.

    2000-04-03

    This package is written to comply with EN-6-035-00 for upgrade dedication of commercial grade items (CGI). The SNF-5953 CGI package provides the Technical evaluation to identify the critical characteristics and the acceptance criteria associated with the safety function of the Hood Stand Support Steel. Completion of the technical and quality requirements identified in the dedication package will provide enough data to be reasonably assured that CGI Hood Stand Support Steel will perform its SC function.

  3. Ceramic automotive Stirling engine program

    NASA Technical Reports Server (NTRS)

    1986-01-01

    The Ceramic Automotive Stirling Engine Program evaluated the application of advanced ceramic materials to an automotive Stirling engine. The objective of the program was to evaluate the technical feasibility of utilizing advanced ceramics to increase peak engine operating temperature, and to evaluate the performance benefits of such an increase. Manufacturing cost estimates were also developed for various ceramic engine components and compared with conventional metallic engine component costs.

  4. [The development and evaluation of software to verify diagnostic accuracy].

    PubMed

    Jensen, Rodrigo; de Moraes Lopes, Maria Helena Baena; Silveira, Paulo Sérgio Panse; Ortega, Neli Regina Siqueira

    2012-02-01

    This article describes the development and evaluation of software that verifies the accuracy of diagnoses made by nursing students. The software was based on a model that uses fuzzy logic concepts, including PERL, the MySQL database for Internet accessibility, and the NANDA-I 2007-2008 classification system. The software was evaluated in terms of its technical quality and usability through specific instruments. The activity proposed in the software involves four stages in which students establish the relationship values between nursing diagnoses, defining characteristics/risk factors and clinical cases. The relationship values determined by students are compared to those of specialists, generating performance scores for the students. In the evaluation, the software demonstrated satisfactory outcomes regarding the technical quality and, according to the students, helped in their learning and may become an educational tool to teach the process of nursing diagnosis.

  5. 16 CFR 1406.5 - Performance and technical data to be furnished to the Commission.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Commission the following performance and technical data related to performance and safety. (a) Written notice... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Performance and technical data to be... TECHNICAL DATA § 1406.5 Performance and technical data to be furnished to the Commission. Manufacturers...

  6. 16 CFR 1401.5 - Providing performance and technical data to purchasers by labeling.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 16 Commercial Practices 2 2014-01-01 2014-01-01 false Providing performance and technical data to...: REQUIREMENTS TO PROVIDE THE COMMISSION WITH PERFORMANCE AND TECHNICAL DATA; REQUIREMENTS TO NOTIFY CONSUMERS AT POINT OF PURCHASE OF PERFORMANCE AND TECHNICAL DATA § 1401.5 Providing performance and technical data to...

  7. 16 CFR 1401.5 - Providing performance and technical data to purchasers by labeling.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Providing performance and technical data to...: REQUIREMENTS TO PROVIDE THE COMMISSION WITH PERFORMANCE AND TECHNICAL DATA; REQUIREMENTS TO NOTIFY CONSUMERS AT POINT OF PURCHASE OF PERFORMANCE AND TECHNICAL DATA § 1401.5 Providing performance and technical data to...

  8. 16 CFR 1401.5 - Providing performance and technical data to purchasers by labeling.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Providing performance and technical data to...: REQUIREMENTS TO PROVIDE THE COMMISSION WITH PERFORMANCE AND TECHNICAL DATA; REQUIREMENTS TO NOTIFY CONSUMERS AT POINT OF PURCHASE OF PERFORMANCE AND TECHNICAL DATA § 1401.5 Providing performance and technical data to...

  9. 16 CFR 1401.5 - Providing performance and technical data to purchasers by labeling.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Providing performance and technical data to...: REQUIREMENTS TO PROVIDE THE COMMISSION WITH PERFORMANCE AND TECHNICAL DATA; REQUIREMENTS TO NOTIFY CONSUMERS AT POINT OF PURCHASE OF PERFORMANCE AND TECHNICAL DATA § 1401.5 Providing performance and technical data to...

  10. Integrated modeling tool for performance engineering of complex computer systems

    NASA Technical Reports Server (NTRS)

    Wright, Gary; Ball, Duane; Hoyt, Susan; Steele, Oscar

    1989-01-01

    This report summarizes Advanced System Technologies' accomplishments on the Phase 2 SBIR contract NAS7-995. The technical objectives of the report are: (1) to develop an evaluation version of a graphical, integrated modeling language according to the specification resulting from the Phase 2 research; and (2) to determine the degree to which the language meets its objectives by evaluating ease of use, utility of two sets of performance predictions, and the power of the language constructs. The technical approach followed to meet these objectives was to design, develop, and test an evaluation prototype of a graphical, performance prediction tool. The utility of the prototype was then evaluated by applying it to a variety of test cases found in the literature and in AST case histories. Numerous models were constructed and successfully tested. The major conclusion of this Phase 2 SBIR research and development effort is that complex, real-time computer systems can be specified in a non-procedural manner using combinations of icons, windows, menus, and dialogs. Such a specification technique provides an interface that system designers and architects find natural and easy to use. In addition, PEDESTAL's multiview approach provides system engineers with the capability to perform the trade-offs necessary to produce a design that meets timing performance requirements. Sample system designs analyzed during the development effort showed that models could be constructed in a fraction of the time required by non-visual system design capture tools.

  11. Systems and technologies for objective evaluation of technical skills in laparoscopic surgery.

    PubMed

    Sánchez-Margallo, Juan A; Sánchez-Margallo, Francisco M; Oropesa, Ignacio; Gómez, Enrique J

    2014-01-01

    Minimally invasive surgery is a highly demanding surgical approach regarding technical requirements for the surgeon, who must be trained in order to perform a safe surgical intervention. Traditional surgical education in minimally invasive surgery is commonly based on subjective criteria to quantify and evaluate surgical abilities, which could be potentially unsafe for the patient. Authors, surgeons and associations are increasingly demanding the development of more objective assessment tools that can accredit surgeons as technically competent. This paper describes the state of the art in objective assessment methods of surgical skills. It gives an overview on assessment systems based on structured checklists and rating scales, surgical simulators, and instrument motion analysis. As a future work, an objective and automatic assessment method of surgical skills should be standardized as a means towards proficiency-based curricula for training in laparoscopic surgery and its certification.

  12. Crowdsourcing Assessment of Surgeon Dissection of Renal Artery and Vein During Robotic Partial Nephrectomy: A Novel Approach for Quantitative Assessment of Surgical Performance.

    PubMed

    Powers, Mary K; Boonjindasup, Aaron; Pinsky, Michael; Dorsey, Philip; Maddox, Michael; Su, Li-Ming; Gettman, Matthew; Sundaram, Chandru P; Castle, Erik P; Lee, Jason Y; Lee, Benjamin R

    2016-04-01

    We sought to describe a methodology of crowdsourcing for obtaining quantitative performance ratings of surgeons performing renal artery and vein dissection of robotic partial nephrectomy (RPN). We sought to compare assessment of technical performance obtained from the crowdsourcers with that of surgical content experts (CE). Our hypothesis is that the crowd can score performances of renal hilar dissection comparably to surgical CE using the Global Evaluative Assessment of Robotic Skills (GEARS). A group of resident and attending robotic surgeons submitted a total of 14 video clips of RPN during hilar dissection. These videos were rated by both crowd and CE for technical skills performance using GEARS. A minimum of 3 CE and 30 Amazon Mechanical Turk crowdworkers evaluated each video with the GEARS scale. Within 13 days, we received ratings of all videos from all CE, and within 11.5 hours, we received 548 GEARS ratings from crowdworkers. Even though CE were exposed to a training module, internal consistency across videos of CE GEARS ratings remained low (ICC = 0.38). Despite this, we found that crowdworker GEARS ratings of videos were highly correlated with CE ratings at both the video level (R = 0.82, p < 0.001) and surgeon level (R = 0.84, p < 0.001). Similarly, crowdworker ratings of the renal artery dissection were highly correlated with expert assessments (R = 0.83, p < 0.001) for the unique surgery-specific assessment question. We conclude that crowdsourced assessment of qualitative performance ratings may be an alternative and/or adjunct to surgical experts' ratings and would provide a rapid scalable solution to triage technical skills.

  13. An integrated evaluation for the performance of clinical engineering department.

    PubMed

    Yousry, Ahmed M; Ouda, Bassem K; Eldeib, Ayman M

    2014-01-01

    Performance benchmarking have become a very important component in all successful organizations nowadays that must be used by Clinical Engineering Department (CED) in hospitals. Many researchers identified essential mainstream performance indicators needed to improve the CED's performance. These studies revealed mainstream performance indicators that use the database of a CED to evaluate its performance. In this work, we believe that those indicators are insufficient for hospitals. Additional important indicators should be included to improve the evaluation accuracy. Therefore, we added new indicators: technical/maintenance indicators, economic indicators, intrinsic criticality indicators, basic hospital indicators, equipment acquisition, and safety indicators. Data is collected from 10 hospitals that cover different types of healthcare organizations. We developed a software tool that analyses collected data to provide a score for each CED under evaluation. Our results indicate that there is an average gap of 67% between the CEDs' performance and the ideal target. The reasons for the noncompliance are discussed in order to improve performance of CEDs under evaluation.

  14. Performance evaluation of traffic sensing and control devices : [technical summary].

    DOT National Transportation Integrated Search

    2011-01-01

    High quality sensing and control systems are essential for providing efficient signalized arterial operations. INDOT operates over 2600 traffic signal controllers, approximately 2000 of which use some form of vehicle detection. The private sector con...

  15. Level of Service Program for INDOT Operations : [Technical Summary

    DOT National Transportation Integrated Search

    2012-01-01

    In 2008 the JTRP study SPR-3130, Performance Based : Contracting for Roadway Maintenance Operations, : revealed the state agencies that have developed a : Level of Service (LOS) program benefit. A LOS program : can evaluate and determine maintenance ...

  16. ITS pilot project demonstration program summary report

    DOT National Transportation Integrated Search

    2008-12-01

    The purpose of this contract is to conduct a technical performance analysis and operational evaluation of ITS projects : demonstrated at the Innovative Mobility Experience Showcase in conjunction with the 2005 ITS World Congress. Some : of these proj...

  17. Evaluation of pavement surface friction treatments : [technical summary].

    DOT National Transportation Integrated Search

    2011-01-01

    The implementation of a pavement preservation program involves a learning curve with not only a determination to succeed, but also the courage to fail. Successful implementation of pavement preservation program requires knowledge of the performance o...

  18. Flight test and evaluation of Omega navigation in a general aviation aircraft. Volume 1: Technical

    NASA Technical Reports Server (NTRS)

    Howell, J. D.; Hoffman, W. C.; Hwoschinsky, P. V.; Wischmeyer, C. E.

    1975-01-01

    A low cost flight research program was conducted to evaluate the performance of differential Omega navigation in a general aviation aircraft. The flight program consisted of two distinct parts corresponding to the two major objectives of the study. The Wallops Flight Program was conducted to obtain Omega signal and phase data in the Wallops Flight Center vicinity to provide preliminary technical information and experience in preparation for a comprehensive NASA/FAA flight test program of an experimental differential Omega system. The Northeast Corridor Flight Program was conducted to examine Omega operational suitability and performance on low altitude area navigation (RNAV) routes for city-center to city-center VTOL commercial operations in the Boston-New York-Washington corridor. The development, execution and conclusions of the flight research program are discribed. The results of the study provide both quantitative and qualitative data on the Omega Navigation System under actual operating conditions.

  19. NASA new technology identification and evaluation

    NASA Technical Reports Server (NTRS)

    Lizak, R. M.

    1983-01-01

    Before disclosure in NASA Tech Briefs, reports of new technology are transmitted to the cognizant NASA Field Center Technology Utilization Office (TUO) where they are evaluated for novelty, technical validity and significance, and nonaerospace utility. If uncertainty exists regarding these criteria, the documentation may be forwarded to SRI International for evaluation before recommending publication. From November 1980 to November 1983, some 3,103 technologies were evaluated by SRI. Activities performed and progress made are summarized.

  20. Quantitative Imaging Biomarkers: A Review of Statistical Methods for Technical Performance Assessment

    PubMed Central

    2017-01-01

    Technological developments and greater rigor in the quantitative measurement of biological features in medical images have given rise to an increased interest in using quantitative imaging biomarkers (QIBs) to measure changes in these features. Critical to the performance of a QIB in preclinical or clinical settings are three primary metrology areas of interest: measurement linearity and bias, repeatability, and the ability to consistently reproduce equivalent results when conditions change, as would be expected in any clinical trial. Unfortunately, performance studies to date differ greatly in designs, analysis method and metrics used to assess a QIB for clinical use. It is therefore, difficult or not possible to integrate results from different studies or to use reported results to design studies. The Radiological Society of North America (RSNA) and the Quantitative Imaging Biomarker Alliance (QIBA) with technical, radiological and statistical experts developed a set of technical performance analysis methods, metrics and study designs that provide terminology, metrics and methods consistent with widely accepted metrological standards. This document provides a consistent framework for the conduct and evaluation of QIB performance studies so that results from multiple studies can be compared, contrasted or combined. PMID:24919831

  1. 16 CFR § 1401.5 - Providing performance and technical data to purchasers by labeling.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 16 Commercial Practices 2 2013-01-01 2013-01-01 false Providing performance and technical data to...: REQUIREMENTS TO PROVIDE THE COMMISSION WITH PERFORMANCE AND TECHNICAL DATA; REQUIREMENTS TO NOTIFY CONSUMERS AT POINT OF PURCHASE OF PERFORMANCE AND TECHNICAL DATA § 1401.5 Providing performance and technical data to...

  2. The acceptability of TV-based game platforms as an instrument to support the cognitive evaluation of senior adults at home

    PubMed Central

    Rivas Costa, Carlos; Anido Rifón, Luis Eulogio; Gómez Carballa, Miguel; Valladares Rodríguez, Sonia

    2017-01-01

    Introduction The computing capabilities of state-of-the-art television sets and media centres may facilitate the introduction of computer-assisted evaluation at home. This approach would help to overcome the drawbacks of traditional pen-and-paper evaluations administered in clinical facilities, as they could be performed in a more comfortable environment, the subject’s home, and they would be more flexible for designing complex environments for the evaluation of neuropsychological constructs that are difficult to assess through traditional testing. The objective of this work was to obtain some initial evidence about the technical acceptance by senior adults of serious games played at home on the TV set and therefore about the convenience of further investigating such an approach to cognitive assesment. Materials and Methods We developed a collection of games to be deployed on a TV environment. These games were tried by a group of senior adults at their homes. The Technology Acceptance Model (TAM) was used to validate this approach. Surveys were performed to study the perceived usefulness and perceived ease of use of such technical setting as an instrument for their cognitive evaluation; that is, its technical acceptance. Subjective information collected from participants was correlated with actual interaction data captured. An additional survey was performed 36 months after pilot testing to have an indication about the long-term perceptions about usefulness and ease of use. Results More than 90% of participating subjects perceived cognitive games on TV as useful or very useful. The majority of participants selected the TV set as their preferred option to interact with serious games at home, when compared to other devices such as smartphones, tablets or PCs. This result correlates with the number of participants perceiving them as easily usable or very easy to use, and also with automatically captured interaction data. Three out of four seniors expressed their interest in keeping the system at home after the pilot. Besides, these perceptions are fairly stable in time as shown by the survey performed 36 months after pilot testing. Limitations Although participating users are a representative sample of the Galician population, which in turn is comparable to the population of most rural areas in Europe, a larger and more diverse user sample would be needed to obtain significant results for a wider population profile. Conclusion The study confirmed the technical acceptance, that is, the perceived usefulness and perceived ease of use, of the TV-based home technical setting introduced as a means of cognitive evaluation. This study provides initial evidence on the viability of a TV-based serious games approach for cognitive longitudinal screening at home with little intervention of clinical professionals, thus contributing to the early detection of cognitive impairments in the senior population. PMID:28070464

  3. An adaptive toolkit for image quality evaluation in system performance test of digital breast tomosynthesis

    NASA Astrophysics Data System (ADS)

    Zhang, Guozhi; Petrov, Dimitar; Marshall, Nicholas; Bosmans, Hilde

    2017-03-01

    Digital breast tomosynthesis (DBT) is a relatively new diagnostic imaging modality for women. Currently, various models of DBT systems are available on the market and the number of installations is rapidly increasing. EUREF, the European Reference Organization for Quality Assured Breast Screening and Diagnostic Services, has proposed a preliminary Guideline - protocol for the quality control of the physical and technical aspects of digital breast tomosynthesis systems, with an ultimate aim of providing limiting values guaranteeing proper performance for different applications of DBT. In this work, we introduce an adaptive toolkit developed in accordance with this guideline to facilitate the process of image quality evaluation in DBT performance test. This toolkit implements robust algorithms to quantify various technical parameters of DBT images and provides a convenient user interface in practice. Each test is built into a separate module with configurations set corresponding to the European guideline, which can be easily adapted to different settings and extended with additional tests. This toolkit largely improves the efficiency for image quality evaluation of DBT. It is also going to evolve with the development of protocols in quality control of DBT systems.

  4. RFA Guardian: Comprehensive Simulation of Radiofrequency Ablation Treatment of Liver Tumors.

    PubMed

    Voglreiter, Philip; Mariappan, Panchatcharam; Pollari, Mika; Flanagan, Ronan; Blanco Sequeiros, Roberto; Portugaller, Rupert Horst; Fütterer, Jurgen; Schmalstieg, Dieter; Kolesnik, Marina; Moche, Michael

    2018-01-15

    The RFA Guardian is a comprehensive application for high-performance patient-specific simulation of radiofrequency ablation of liver tumors. We address a wide range of usage scenarios. These include pre-interventional planning, sampling of the parameter space for uncertainty estimation, treatment evaluation and, in the worst case, failure analysis. The RFA Guardian is the first of its kind that exhibits sufficient performance for simulating treatment outcomes during the intervention. We achieve this by combining a large number of high-performance image processing, biomechanical simulation and visualization techniques into a generalized technical workflow. Further, we wrap the feature set into a single, integrated application, which exploits all available resources of standard consumer hardware, including massively parallel computing on graphics processing units. This allows us to predict or reproduce treatment outcomes on a single personal computer with high computational performance and high accuracy. The resulting low demand for infrastructure enables easy and cost-efficient integration into the clinical routine. We present a number of evaluation cases from the clinical practice where users performed the whole technical workflow from patient-specific modeling to final validation and highlight the opportunities arising from our fast, accurate prediction techniques.

  5. DOE standard: The Department of Energy Laboratory Accreditation Program for radiobioassay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-12-01

    This technical standard describes the US Department of Energy Laboratory Accreditation Program (DOELAP) for Radiobioassay, for use by the US Department of Energy (DOE) and DOE Contractor radiobioassay programs. This standard is intended to be used in conjunction with the general administrative technical standard that describes the overall DOELAP accreditation process--DOE-STD-1111-98, Department of Energy Laboratory Accreditation Program Administration. This technical standard pertains to radiobioassay service laboratories that provide either direct or indirect (in vivo or in vitro) radiobioassay measurements in support of internal dosimetry programs at DOE facilities or for DOE and DOE contractors. Similar technical standards have been developedmore » for other DOELAP dosimetry programs. This program consists of providing an accreditation to DOE radiobioassay programs based on successful completion of a performance-testing process and an on-site evaluation by technical experts. This standard describes the technical requirements and processes specific to the DOELAP Radiobioassay Accreditation Program as required by 10 CFR 835 and as specified generically in DOE-STD-1111-98.« less

  6. Performance of two different digital evaluation systems used for assessing pre-clinical dental students' prosthodontic technical skills.

    PubMed

    Gratton, D G; Kwon, S R; Blanchette, D R; Aquilino, S A

    2017-11-01

    Proper integration of newly emerging digital assessment tools is a central issue in dental education in an effort to provide more accurate and objective feedback to students. The study examined how the outcomes of students' tooth preparation were correlated when evaluated using traditional faculty assessment and two types of digital assessment approaches. Specifically, incorporation of the Romexis Compare 2.0 (Compare) and Sirona prepCheck 1.1 (prepCheck) systems was evaluated. Additionally, satisfaction of students based on the type of software was evaluated through a survey. Students in a second-year pre-clinical prosthodontics course were allocated to either Compare (n = 42) or prepCheck (n = 37) systems. All students received conventional instruction and used their assigned digital system as an additional evaluation tool to aid in assessing their work. Examinations assessed crown preparations of the maxillary right central incisor (#8) and the mandibular left first molar (#19). All submissions were graded by faculty, Compare and prepCheck. Technical scores did not differ between student groups for any of the assessment approaches. Compare and prepCheck had modest, statistically significant correlations with faculty scores with a minimum correlation of 0.3944 (P = 0.0011) and strong, statistically significant correlations with each other with a minimum correlation of 0.8203 (P < 0.0001). A post-course student survey found that 55.26% of the students felt unfavourably about learning the digital evaluation protocols. A total of 62.31% felt favourably about the integration of these digital tools into the curriculum. Comparison of Compare and prepCheck showed no evidence of significant difference in students' prosthodontics technical performance and perception. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. An Experimental Evaluation of Stress-Management Training for the Airborne Soldier. Technical Report 550.

    ERIC Educational Resources Information Center

    Burke, William P.

    A project was conducted to evaluate the effectiveness of the stress-management training given to students in the jumpmaster training course at Fort Benning, Georgia. The course, which trains airborne personnel to conduct landings of men and equipment, features relatively stressful training programs during which instructors grade the performance of…

  8. The Captive Helicopter as a Training Device: Experimental Evaluation of a Concept. Technical Report 68-9.

    ERIC Educational Resources Information Center

    Caro, Paul W., Jr.; And Others

    As part of the Army's effort to use synthetic devices to improve training, researchers evaluated a captive helicopter attached to a ground effects machine. Experimental groups received varying amounts of pre-flight practice tasks designed to develop flight skills, while control groups received no device training. Student flight performance during…

  9. Evaluation of generation 3 treatment technology for swine waste - A North Carolina's clean water management trust fund project - Technical environmental performance report

    USDA-ARS?s Scientific Manuscript database

    This project evaluated and demonstrated the viability of a third generation manure treatment technology. The technology was developed as an alternative to the lagoon/spray field system typically used to treat the wastewater generated by swine farms in North Carolina. It separates solids and liquids ...

  10. An evaluation of client satisfaction with training programs and technical assistance provided by Florida's Coordinated School Health Program Office.

    PubMed

    Weiler, R M; Pigg, R M

    2000-11-01

    Client or customer satisfaction surveys assess the perceived quality of programs, products, services, and employee performance. Such assessments prove beneficial for evaluation and planning purposes. This survey examined the satisfaction of clients using the programs, services, and technical assistance provided through the Coordinated School Health Program Office (CSHPO) in the Florida Department of Education. Using the 42-item Client Satisfaction Survey, data were collected in summer 1999 from 300 of 574 clients (52.3%) who attended training sessions or sought technical assistance from CSHPO during 1996-1999. More than two-thirds (67.2%) of clients rated the training program as "very good" or "excellent" at increasing their understanding about the concept of a coordinated school health program. Overall, 69.7% of clients rated the training programs they attended as "very good" or "excellent." Resource materials and staff effectiveness rated positively as well. Findings confirmed client satisfaction with CSHPO's training programs, technical assistance, and staff. Information obtained through the client satisfaction survey can be used by CSHPO to assist in future program planning and resource allocations.

  11. Voluntary Medical Male Circumcision Scale-Up in Nyanza, Kenya: Evaluating Technical Efficiency and Productivity of Service Delivery

    PubMed Central

    Omondi Aduda, Dickens S.; Ouma, Collins; Onyango, Rosebella; Onyango, Mathews; Bertrand, Jane

    2015-01-01

    Background Voluntary medical male circumcision (VMMC) service delivery is complex and resource-intensive. In Kenya’s context there is still paucity of information on resource use vis-à-vis outputs as programs scale up. Knowledge of technical efficiency, productivity and potential sources of constraints is desirable to improve decision-making. Objective To evaluate technical efficiency and productivity of VMMC service delivery in Nyanza in 2011/2012 using data envelopment analysis. Design Comparative process evaluation of facilities providing VMMC in Nyanza in 2011/2012 using output orientated data envelopment analysis. Results Twenty one facilities were evaluated. Only 1 of 7 variables considered (total elapsed operation time) significantly improved from 32.8 minutes (SD 8.8) in 2011 to 30 minutes (SD 6.6) in 2012 (95%CI = 0.0350–5.2488; p = 0.047). Mean scale technical efficiency significantly improved from 91% (SD 19.8) in 2011 to 99% (SD 4.0) in 2012 particularly among outreach compared to fixed service delivery facilities (CI -31.47959–4.698508; p = 0.005). Increase in mean VRS technical efficiency from 84% (SD 25.3) in 2011 and 89% (SD 25.1) in 2012 was not statistically significant. Benchmark facilities were #119 and #125 in 2011 and #103 in 2012. Malmquist Productivity Index (MPI) at fixed facilities declined by 2.5% but gained by 4.9% at outreach ones by 2012. Total factor productivity improved by 83% (p = 0.032) in 2012, largely due to progress in technological efficiency by 79% (p = 0.008). Conclusions Significant improvement in scale technical efficiency among outreach facilities in 2012 was attributable to accelerated activities. However, ongoing pure technical inefficiency requires concerted attention. Technological progress was the key driver of service productivity growth in Nyanza. Incorporating service-quality dimensions and using stepwise-multiple criteria in performance evaluation enhances comprehensiveness and validity. These findings highlight site-level resource use and sources of variations in VMMC service productivity, which are important for program planning. PMID:25706119

  12. Technical Evaluation Motor no. 5 (TEM-5)

    NASA Technical Reports Server (NTRS)

    Cook, M.

    1990-01-01

    Technical Evaluation Motor No. 5 (TEM-5) was static test fired at the Thiokol Corporation Static Test Bay T-97. TEM-5 was a full scale, full duration static test fire of a high performance motor (HPM) configuration solid rocket motor (SRM). The primary purpose of TEM static tests is to recover SRM case and nozzle hardware for use in the redesigned solid rocket motor (RSRM) flight program. Inspection and instrumentation data indicate that the TEM-5 static test firing was successful. The ambient temperature during the test was 41 F and the propellant mean bulk temperature (PMBT) was 72 F. Ballistics performance values were within the specified requirements. The overall performance of the TEM-5 components and test equipment was nominal. Dissembly inspection revealed that joint putty was in contact with the inner groove of the inner primary seal of the ignitor adapter-to-forward dome (inner) joint gasket; this condition had not occurred on any previous static test motor or flight RSRM. While no qualification issues were addressed on TEM-5, two significant component changes were evaluated. Those changes were a new vented assembly process for the case-to-nozzle joint and the installation of two redesigned field joint protection systems. Performance of the vented case-to-nozzle joint assembly was successful, and the assembly/performance differences between the two field joint protection system (FJPS) configurations were compared.

  13. The Importance of Postural Control in Relation to Technical Abilities in Small-Sided Soccer Games

    PubMed Central

    Edis, Çağlar; Vurgun, Hikmet

    2016-01-01

    Abstract Making assessments regarding postural control and balance is very important for injury prevention in soccer. However, there has been no study that has associated postural control variables with branch-specific technical properties in a game. The aim of the present study was to determine the relationships between variables designating postural control levels and technical performance variables in different (1:1, 2:2 and 3:3) small-sided games (SSGs). Sixteen trained male amateur soccer players volunteered to take part in the study (age 17.2 ± 1.02 years, body height 176.25 ± 0.07 m, body mass 67.67 ± 13.27 kg). Following familiarization sessions, postural control was evaluated using one-leg and both-leg quiet-stance positions by measuring postural sway with a Tekscan HR Mat™ in anterior–posterior and medial–lateral directions. Later, 1:1, 2:2 and 3:3 SSGs were performed at two-day intervals and the technical variables specified for each game were analyzed. A Spearman’s rank-order correlation analysis demonstrated the relationship between postural control and soccer-specific technical variables in 1:1 (r-values ranging from 0.582 to 0.776), 2:2 (rvalues ranging from 0.511 to 0.740) and 3:3 (r-values ranging from 0.502 to 0.834) SSGs. In addition, a Wilcoxon signed rank test revealed differences between SSGs in terms of several variables. The results of the study showed that higher postural control levels are among the important variables that affect success in the performance of technical skills under rival pressure and suddenly changing conditions. Therefore, it is recommended that in addition to its use for injury prevention purposes, balance training should be conducted to improve branch-specific technical skills and to increase the levels of their successful performance in a game. PMID:28149410

  14. The Importance of Postural Control in Relation to Technical Abilities in Small-Sided Soccer Games.

    PubMed

    Edis, Çağlar; Vural, Faik; Vurgun, Hikmet

    2016-12-01

    Making assessments regarding postural control and balance is very important for injury prevention in soccer. However, there has been no study that has associated postural control variables with branch-specific technical properties in a game. The aim of the present study was to determine the relationships between variables designating postural control levels and technical performance variables in different (1:1, 2:2 and 3:3) small-sided games (SSGs). Sixteen trained male amateur soccer players volunteered to take part in the study (age 17.2 ± 1.02 years, body height 176.25 ± 0.07 m, body mass 67.67 ± 13.27 kg). Following familiarization sessions, postural control was evaluated using one-leg and both-leg quiet-stance positions by measuring postural sway with a Tekscan HR Mat™ in anterior-posterior and medial-lateral directions. Later, 1:1, 2:2 and 3:3 SSGs were performed at two-day intervals and the technical variables specified for each game were analyzed. A Spearman's rank-order correlation analysis demonstrated the relationship between postural control and soccer-specific technical variables in 1:1 (r-values ranging from 0.582 to 0.776), 2:2 (rvalues ranging from 0.511 to 0.740) and 3:3 (r-values ranging from 0.502 to 0.834) SSGs. In addition, a Wilcoxon signed rank test revealed differences between SSGs in terms of several variables. The results of the study showed that higher postural control levels are among the important variables that affect success in the performance of technical skills under rival pressure and suddenly changing conditions. Therefore, it is recommended that in addition to its use for injury prevention purposes, balance training should be conducted to improve branch-specific technical skills and to increase the levels of their successful performance in a game.

  15. Effectiveness of facilitated introduction of a standard operating procedure into routine processes in the operating theatre: a controlled interrupted time series.

    PubMed

    Morgan, Lauren; New, Steve; Robertson, Eleanor; Collins, Gary; Rivero-Arias, Oliver; Catchpole, Ken; Pickering, Sharon P; Hadi, Mohammed; Griffin, Damian; McCulloch, Peter

    2015-02-01

    Standard operating procedures (SOPs) should improve safety in the operating theatre, but controlled studies evaluating the effect of staff-led implementation are needed. In a controlled interrupted time series, we evaluated three team process measures (compliance with WHO surgical safety checklist, non-technical skills and technical performance) and three clinical outcome measures (length of hospital stay, complications and readmissions) before and after a 3-month staff-led development of SOPs. Process measures were evaluated by direct observation, using Oxford Non-Technical Skills II for non-technical skills and the 'glitch count' for technical performance. All staff in two orthopaedic operating theatres were trained in the principles of SOPs and then assisted to develop standardised procedures. Staff in a control operating theatre underwent the same observations but received no training. The change in difference between active and control groups was compared before and after the intervention using repeated measures analysis of variance. We observed 50 operations before and 55 after the intervention and analysed clinical data on 1022 and 861 operations, respectively. The staff chose to structure their efforts around revising the 'whiteboard' which documented and prompted tasks, rather than directly addressing specific task problems. Although staff preferred and sustained the new system, we found no significant differences in process or outcome measures before/after intervention in the active versus the control group. There was a secular trend towards worse outcomes in the postintervention period, seen in both active and control theatres. SOPs when developed and introduced by frontline staff do not necessarily improve operative processes or outcomes. The inherent tension in improvement work between giving staff ownership of improvement and maintaining control of direction needs to be managed, to ensure staff are engaged but invest energy in appropriate change. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  16. A Learning Evaluation for an Immersive Virtual Laboratory for Technical Training Applied into a Welding Workshop

    ERIC Educational Resources Information Center

    Torres, Francisco; Neira Tovar, Leticia A.; del Rio, Marta Sylvia

    2017-01-01

    This study aims to explore the results of welding virtual training performance, designed using a learning model based on cognitive and usability techniques, applying an immersive concept focused on person attention. Moreover, it also intended to demonstrate that exits a moderating effect of performance improvement when the user experience is taken…

  17. Performance Assessments in Science: Hands-On Tasks and Scoring Guides.

    ERIC Educational Resources Information Center

    Stecher, Brian M.; Klein, Stephen P.

    In 1992, RAND received a grant from the National Science Foundation to study the technical quality of performance assessments in science and to evaluate their feasibility for use in large-scale testing programs. The specific goals of the project were to assess the reliability and validity of hands-on science testing and to investigate the cost and…

  18. Prevalence of technical errors and periapical lesions in a sample of endodontically treated teeth: a CBCT analysis.

    PubMed

    Nascimento, Eduarda Helena Leandro; Gaêta-Araujo, Hugo; Andrade, Maria Fernanda Silva; Freitas, Deborah Queiroz

    2018-01-21

    The aims of this study are to identify the most frequent technical errors in endodontically treated teeth and to determine which root canals were most often associated with those errors, as well as to relate endodontic technical errors and the presence of coronal restorations with periapical status by means of cone-beam computed tomography images. Six hundred eighteen endodontically treated teeth (1146 root canals) were evaluated for the quality of their endodontic treatment and for the presence of coronal restorations and periapical lesions. Each root canal was classified according to dental groups, and the endodontic technical errors were recorded. Chi-square's test and descriptive analyses were performed. Six hundred eighty root canals (59.3%) had periapical lesions. Maxillary molars and anterior teeth showed higher prevalence of periapical lesions (p < 0.05). Endodontic treatment quality and coronal restoration were associated with periapical status (p < 0.05). Underfilling was the most frequent technical error in all root canals, except for the second mesiobuccal root canal of maxillary molars and the distobuccal root canal of mandibular molars, which were non-filled in 78.4 and 30% of the cases, respectively. There is a high prevalence of apical radiolucencies, which increased in the presence of poor coronal restorations, endodontic technical errors, and when both conditions were concomitant. Underfilling was the most frequent technical error, followed by non-homogeneous and non-filled canals. Evaluation of endodontic treatment quality that considers every single root canal aims on warning dental practitioners of the prevalence of technical errors that could be avoided with careful treatment planning and execution.

  19. 48 CFR 9.502 - Applicability.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... CONTRACTOR QUALIFICATIONS Organizational and Consultant Conflicts of Interest 9.502 Applicability. (a) This... limited to any particular kind of acquisition. However, organizational conflicts of interest are more... professional services; (3) Contractor performance of or assistance in technical evaluations; or (4) Systems...

  20. Level of Service Program for INDOT Operations : [Technical Summary

    DOT National Transportation Integrated Search

    2012-01-01

    In 2008 the JTRP study SPR-3130, Performance Based Contracting for Roadway Maintenance Operations, revealed the state agencies that have developed a Level of Service (LOS) program benefit. A LOS program can evaluate and determine maintenance performa...

  1. 34 CFR 403.204 - What are the State's responsibilities for program evaluation and improvement?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... has not made sufficient progress in meeting the standards and measures developed as required by §§ 403... technical assistance and program activities the State will provide to enhance the performance of the...

  2. Brief Lags in Interrupted Sequential Performance: Evaluating a Model and Model Evaluation Method

    DTIC Science & Technology

    2015-01-05

    rehearsal mechanism in the model. To evaluate the model we developed a simple new goodness-of-fit test based on analysis of variance that offers an...repeated step). Sequen- tial constraints are common in medicine, equipment maintenance, computer programming and technical support, data analysis ...legal analysis , accounting, and many other home and workplace environ- ments. Sequential constraints also play a role in such basic cognitive processes

  3. Army Blast Claims Evaluation Procedures

    DTIC Science & Technology

    1994-03-01

    ARMY RESEARCH LABORATORY ARL-MR-131 Army Blast Claims Evaluation Procedures William P. Wright APPROVED FOR PUBUC RELEASE; DISTRIBtmON IS...NUMBERS Anny Blast Claims Evaluation Procedures 4G061-304-U2 6. AUTHOR(S) William P. Wrisht 1. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) 8...of the technical review process which bas been instituted to develop an opinion as to Army responsibility. 14. SUBJECT TERMS blast effects. muzzle

  4. Technology and development requirements for advanced coal conversion systems

    NASA Technical Reports Server (NTRS)

    1981-01-01

    A compendium of coal conversion process descriptions is presented. The SRS and MC data bases were utilized to provide information paticularly in the areas of existing process designs and process evaluations. Additional information requirements were established and arrangements were made to visit process developers, pilot plants, and process development units to obtain information that was not otherwise available. Plant designs, process descriptions and operating conditions, and performance characteristics were analyzed and requirements for further development identified and evaluated to determine the impact of these requirements on the process commercialization potential from the standpoint of economics and technical feasibility. A preliminary methodology was established for the comparative technical and economic assessment of advanced processes.

  5. Percutaneous Aspiration Thrombectomy for the Treatment of Arterial Thromboembolic Occlusions Following Percutaneous Transluminal Angioplasty

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schleder, Stephan, E-mail: stephan.schleder@ukr.de; Diekmann, Matthias; Manke, Christoph

    2015-02-15

    PurposeThis study was designed to evaluate the technical success and the early clinical outcome of patients undergoing percutaneous aspiration thrombectomy (PAT) for the treatment of arterial thromboembolism following percutaneous infrainguinal transluminal angioplasty (PTA).MethodsIn this single-center study, during a period of 7 years retrospectively, 47 patients (22 male, 47 %) with a mean age of 73 (range 53–96) years were identified in whom PAT was performed for the treatment of thromboembolic complications of infrainguinal PTA. Primary technical success was defined as residual stenosis of <50 % in diameter after sole PAT, whereas secondary technical success was defined as residual stenosis of <50 % in diametermore » after PAT and additional PTA and/or stenting. Clinical outcome parameters (e.g., need for further intervention, minor/major amputation) were evaluated for the 30-day postinterventional period.ResultsPrimary technical success was achieved in 64 % of patients (30/47); secondary technical success was obtained in 96 % of patients (45/47). Clinical outcome data were available in 38 patients. In 87 % of patients (33/38), there was no need for further intervention within the 30-day postinterventional period. In three patients, minor amputations were conducted due to preexisting ulcerations (Rutherford Category 5 respectively).ConclusionsPAT enables endovascular treatment of iatrogenic thromboembolic complications after PTA with good technical and early clinical results and minimal morbidity.« less

  6. CT-guided bipolar and multipolar radiofrequency ablation (RF ablation) of renal cell carcinoma: specific technical aspects and clinical results.

    PubMed

    Sommer, C M; Lemm, G; Hohenstein, E; Bellemann, N; Stampfl, U; Goezen, A S; Rassweiler, J; Kauczor, H U; Radeleff, B A; Pereira, P L

    2013-06-01

    This study was designed to evaluate the clinical efficacy of CT-guided bipolar and multipolar radiofrequency ablation (RF ablation) of renal cell carcinoma (RCC) and to analyze specific technical aspects between both technologies. We included 22 consecutive patients (3 women; age 74.2 ± 8.6 years) after 28 CT-guided bipolar or multipolar RF ablations of 28 RCCs (diameter 2.5 ± 0.8 cm). Procedures were performed with a commercially available RF system (Celon AG Olympus, Berlin, Germany). Technical aspects of RF ablation procedures (ablation mode [bipolar or multipolar], number of applicators and ablation cycles, overall ablation time and deployed energy, and technical success rate) were analyzed. Clinical results (local recurrence-free survival and local tumor control rate, renal function [glomerular filtration rate (GFR)]) and complication rates were evaluated. Bipolar RF ablation was performed in 12 procedures and multipolar RF ablation in 16 procedures (2 applicators in 14 procedures and 3 applicators in 2 procedures). One ablation cycle was performed in 15 procedures and two ablation cycles in 13 procedures. Overall ablation time and deployed energy were 35.0 ± 13.6 min and 43.7 ± 17.9 kJ. Technical success rate was 100 %. Major and minor complication rates were 4 and 14 %. At an imaging follow-up of 15.2 ± 8.8 months, local recurrence-free survival was 14.4 ± 8.8 months and local tumor control rate was 93 %. GFR did not deteriorate after RF ablation (50.8 ± 16.6 ml/min/1.73 m(2) before RF ablation vs. 47.2 ± 11.9 ml/min/1.73 m(2) after RF ablation; not significant). CT-guided bipolar and multipolar RF ablation of RCC has a high rate of clinical success and low complication rates. At short-term follow-up, clinical efficacy is high without deterioration of the renal function.

  7. 48 CFR 315.305 - Proposal evaluation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... following elements: (1) An explanation of the evaluation process and the role of evaluators throughout the... include, at a minimum, the following elements: (1) A list of recommended technical evaluation panel... that the technical evaluation will have in the award decision. (2) The technical evaluation process...

  8. High-fidelity simulation-based team training in urology: evaluation of technical and nontechnical skills of urology residents during laparoscopic partial nephrectomy.

    PubMed

    Abdelshehid, Corollos S; Quach, Stephen; Nelson, Corey; Graversen, Joseph; Lusch, Achim; Zarraga, Jerome; Alipanah, Reza; Landman, Jaime; McDougall, Elspeth M

    2013-01-01

    The use of low-risk simulation training for resident education is rapidly expanding as teaching centers integrate simulation-based team training (SBTT) sessions into their education curriculum. SBTT is a valuable tool in technical and communication skills training and assessment for residents. We created a unique SBTT scenario for urology residents involving a laparoscopic partial nephrectomy procedure. Urology residents were randomly paired with a certified registered nurse anesthetists or an anesthesia resident. The scenario incorporated a laparoscopic right partial nephrectomy utilizing a unique polyvinyl alcohol kidney model with an embedded 3cm lower pole exophytic tumor and the high-fidelity SimMan3G mannequin. The Urology residents were instructed to pay particular attention to the patient's identifying information provided at the beginning of the case. Two scripted events occurred, the patient had an anaphylactic reaction to a drug and, after tumor specimen was sent for a frozen section, the confederate pathologist called into the operating room (OR) twice, first with the wrong patient name and subsequently with the wrong specimen. After the scenario was complete, technical performance and nontechnical performance were evaluated and assessed. A debriefing session followed the scenario to discuss and assess technical performance and interdisciplinary nontechnical communication between the team. All Urology residents (n = 9) rated the SBTT scenario as a useful tool in developing communication skills among the OR team and 88% rated the model as useful for technical skills training. Despite cuing to note patient identification, only 3 of 9 (33%) participants identified that the wrong patient information was presented when the confederate "pathologist" called in to report pathology results. All urology residents rated SBTT sessions as useful for the development of communication skills between different team members and making residents aware of unlikely but potential critical errors in the OR. We will continue to use SBTT as a useful method to develop resident technical and nontechnical skills outside of the high-risk operating environment. Copyright © 2013 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  9. Quality of pediatric abdominal CT scans performed at a dedicated children's hospital and its referring institutions: a multifactorial evaluation.

    PubMed

    Snow, Aisling; Milliren, Carly E; Graham, Dionne A; Callahan, Michael J; MacDougall, Robert D; Robertson, Richard L; Taylor, George A

    2017-04-01

    Pediatric patients requiring transfer to a dedicated children's hospital from an outside institution may undergo CT imaging as part of their evaluation. Whether this imaging is performed prior to or after transfer has been shown to impact the radiation dose imparted to the patient. Other quality variables could also be affected by the pediatric experience and expertise of the scanning institution. To identify differences in quality between abdominal CT scans and reports performed at a dedicated children's hospital, and those performed at referring institutions. Fifty consecutive pediatric abdominal CT scans performed at outside institutions were matched (for age, gender and indication) with 50 CT scans performed at a dedicated freestanding children's hospital. We analyzed the scans for technical parameters, report findings, correlation with final clinical diagnosis, and clinical utility. Technical evaluation included use of intravenous and oral contrast agents, anatomical coverage, number of scan phases and size-specific dose estimate (SSDE) for each scan. Outside institution scans were re-reported when the child was admitted to the children's hospital; they were also re-interpreted for this study by children's hospital radiologists who were provided with only the referral information given in the outside institution's report. Anonymized original outside institutional reports and children's hospital admission re-reports were analyzed by two emergency medicine physicians for ease of understanding, degree to which the clinical question was answered, and level of confidence in the report. Mean SSDE was lower (8.68) for children's hospital scans, as compared to outside institution scans (13.29, P = 0.03). Concordance with final clinical diagnosis was significantly lower for original outside institution reports (38/48, 79%) than for both the admission and study children's hospital reports (48/50, 96%; P = 0.005). Children's hospital admission reports were rated higher than outside institution reports for completeness, ease of understanding, answering of clinical question, and level of confidence of the report (P < 0.001). Pediatric abdominal CT scans performed and interpreted at a dedicated children's hospital are associated with higher technical quality, lower radiation dose and a more clinically useful report than those performed at referring institutions.

  10. Evaluation of Aeroservoelastic Effects on Flutter

    NASA Technical Reports Server (NTRS)

    Nagaraja, K. S.; Felt, Larry R.; Kraft, Raymond

    1998-01-01

    This report presents work performed by The Boeing Company to satisfy the deliverable "Evaluation of aeroservoelastic Effects on Symmetric Flutter" for Subtask 7 of Reference 1. The objective of this report is to incorporate the improved methods for studying the effects of a closed-loop control system on the aeroservoelastic behavior of the airplane planned under NASA HSR technical Integration Task 20 work. Also, a preliminary evaluation of the existing pitch control laws on symmetric flutter of the TCA configuration was addressed."The goal is to develop an improved modeling methodology and perform design studies that account for the aero-structures-systems interaction effects.

  11. 16 CFR § 1407.3 - Providing performance and technical data to purchasers by labeling.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 16 Commercial Practices 2 2013-01-01 2013-01-01 false Providing performance and technical data to... TECHNICAL DATA BY LABELING § 1407.3 Providing performance and technical data to purchasers by labeling. (a... technical data related to performance and safety to prospective purchasers of such products at the time of...

  12. 16 CFR 1407.3 - Providing performance and technical data to purchasers by labeling.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 16 Commercial Practices 2 2014-01-01 2014-01-01 false Providing performance and technical data to... TECHNICAL DATA BY LABELING § 1407.3 Providing performance and technical data to purchasers by labeling. (a... technical data related to performance and safety to prospective purchasers of such products at the time of...

  13. 16 CFR 1407.3 - Providing performance and technical data to purchasers by labeling.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Providing performance and technical data to... TECHNICAL DATA BY LABELING § 1407.3 Providing performance and technical data to purchasers by labeling. (a... technical data related to performance and safety to prospective purchasers of such products at the time of...

  14. 16 CFR 1407.3 - Providing performance and technical data to purchasers by labeling.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Providing performance and technical data to... TECHNICAL DATA BY LABELING § 1407.3 Providing performance and technical data to purchasers by labeling. (a... technical data related to performance and safety to prospective purchasers of such products at the time of...

  15. 16 CFR 1407.3 - Providing performance and technical data to purchasers by labeling.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Providing performance and technical data to... TECHNICAL DATA BY LABELING § 1407.3 Providing performance and technical data to purchasers by labeling. (a... technical data related to performance and safety to prospective purchasers of such products at the time of...

  16. Relative performance of academic departments using DEA with sensitivity analysis.

    PubMed

    Tyagi, Preeti; Yadav, Shiv Prasad; Singh, S P

    2009-05-01

    The process of liberalization and globalization of Indian economy has brought new opportunities and challenges in all areas of human endeavor including education. Educational institutions have to adopt new strategies to make best use of the opportunities and counter the challenges. One of these challenges is how to assess the performance of academic programs based on multiple criteria. Keeping this in view, this paper attempts to evaluate the performance efficiencies of 19 academic departments of IIT Roorkee (India) through data envelopment analysis (DEA) technique. The technique has been used to assess the performance of academic institutions in a number of countries like USA, UK, Australia, etc. But we are using it first time in Indian context to the best of our knowledge. Applying DEA models, we calculate technical, pure technical and scale efficiencies and identify the reference sets for inefficient departments. Input and output projections are also suggested for inefficient departments to reach the frontier. Overall performance, research performance and teaching performance are assessed separately using sensitivity analysis.

  17. First satellite mobile communication trials using BLQS-CDMA

    NASA Technical Reports Server (NTRS)

    Luzdemateo, Maria; Johns, Simon; Dothey, Michel; Vanhimbeeck, Carl; Deman, Ivan; Wery, Bruno

    1993-01-01

    In this paper, technical results obtained in the first MSBN Land mobile technical trial are reported. MSBN (Mobile Satellite Business Network) is a new program undertaken by the European Space Agency (ESA) to promote mobile satellite communication in Europe, in particular voice capability. The first phase of the MSBN system implementation plan is an experimental phase. Its purpose is to evaluate through field experiments the performance of the MSBN system prior to finalization of its specifications. Particularly, the objective is to verify in the field and possibly improve the performance of the novel satellite access technique BLQS-CDMA (Band Limited Quasi-Synchronous-Code Division Multiple Access), which is proposed as baseline for the MSBN.

  18. Increasing the technical level of mining haul trucks

    NASA Astrophysics Data System (ADS)

    Voronov, Yuri; Voronov, Artyom; Grishin, Sergey; Bujankin, Alexey

    2017-11-01

    Theoretical and methodological fundamentals of mining haul trucks optimal design are articulated. Methods based on the systems approach to integrated assessment of truck technical level and methods for optimization of truck parameters depending on performance standards are provided. The results of using these methods are given. The developed method allows not only assessing the truck technical levels but also choosing the most promising models and providing quantitative evaluations of the decisions to be made at the design stage. These areas are closely connected with the problem of improvement in the industrial output quality, which, being a part of the widely spread in Western world "total quality control" ideology, is one of the major issues for the Russian economy.

  19. Hydrogen turbine power conversion system assessment

    NASA Technical Reports Server (NTRS)

    Wright, D. E.; Lucci, A. D.; Campbell, J.; Lee, J. C.

    1978-01-01

    A three part technical study was conducted whereby parametric technical and economic feasibility data were developed on several power conversion systems suitable for the generation of central station electric power through the combustion of hydrogen and the use of the resulting heat energy in turbogenerator equipment. The study assessed potential applications of hydrogen-fueled power conversion systems and identified the three most promising candidates: (1) Ericsson Cycle, (2) gas turbine, and (3) direct steam injection system for fossil fuel as well as nuclear powerplants. A technical and economic evaluation was performed on the three systems from which the direct injection system (fossil fuel only) was selected for a preliminary conceptual design of an integrated hydrogen-fired power conversion system.

  20. Inertial Sensor Technology for Elite Swimming Performance Analysis: A Systematic Review

    PubMed Central

    Mooney, Robert; Corley, Gavin; Godfrey, Alan; Quinlan, Leo R; ÓLaighin, Gearóid

    2015-01-01

    Technical evaluation of swimming performance is an essential factor of elite athletic preparation. Novel methods of analysis, incorporating body worn inertial sensors (i.e., Microelectromechanical systems, or MEMS, accelerometers and gyroscopes), have received much attention recently from both research and commercial communities as an alternative to video-based approaches. This technology may allow for improved analysis of stroke mechanics, race performance and energy expenditure, as well as real-time feedback to the coach, potentially enabling more efficient, competitive and quantitative coaching. The aim of this paper is to provide a systematic review of the literature related to the use of inertial sensors for the technical analysis of swimming performance. This paper focuses on providing an evaluation of the accuracy of different feature detection algorithms described in the literature for the analysis of different phases of swimming, specifically starts, turns and free-swimming. The consequences associated with different sensor attachment locations are also considered for both single and multiple sensor configurations. Additional information such as this should help practitioners to select the most appropriate systems and methods for extracting the key performance related parameters that are important to them for analysing their swimmers’ performance and may serve to inform both applied and research practices. PMID:26712760

  1. Effects of educational intervention on adherence to the technical recommendations for tracheobronchial aspiration in patients admitted to an intensive care unit

    PubMed Central

    de Lima, Erimara Dall'Agnol; Fleck, Caren Schlottefeld; Borges, Januário José Vieira; Condessa, Robledo Leal; Vieira, Sílvia Regina Rios

    2013-01-01

    Objective To evaluate the effectiveness of an educational intervention on healthcare professionals' adherence to the technical recommendations for tracheobronchial aspiration in intensive care unit patients. Methods A quasi-experimental study was performed to evaluate intensive care unit professionals' adherence to the tracheobronchial aspiration technical recommendations in intensive care unit patients both before and after a theoretical and practical educational intervention. Comparisons were performed using the chi-square test, and the significance level was set to p<0.05. Results A total of 124 procedures, pre- and post-intervention, were observed. Increased adherence was observed in the following actions: the use of personal protective equipment (p=0.01); precaution when opening the catheter package (p<0.001); the use of a sterile glove on the dominant hand to remove the catheter (p=0.003); the contact of the sterile glove with the catheter only (p<0.001); the execution of circular movements during the catheter removal (p<0.001); wrapping the catheter in the sterile glove at the end of the procedure (p=0.003); the use of distilled water, opened at the start of the procedure, to wash the connection latex (p=0.002); the disposal of the leftover distilled water at the end of the procedure (p<0.001); and the performance of the aspiration technique procedures (p<0.001). Conclusion There was a low adherence by health professionals to the preventive measures against hospital infection, indicating the need to implement educational strategies. The educational intervention used was shown to be effective in increasing adherence to the technical recommendations for tracheobronchial aspiration. PMID:23917976

  2. The Relationship Between Technical And Nontechnical Skills Within A Simulation-Based Ureteroscopy Training Environment.

    PubMed

    Brunckhorst, Oliver; Shahid, Shahab; Aydin, Abdullatif; Khan, Shahid; McIlhenny, Craig; Brewin, James; Sahai, Arun; Bello, Fernando; Kneebone, Roger; Shamim Khan, Muhammad; Dasgupta, Prokar; Ahmed, Kamran

    2015-01-01

    Little integration of technical and nontechnical skills (e.g., situational awareness, communication, decision making, teamwork, and leadership) teaching exists within surgery. We therefore aimed to (1) evaluate the relationship between these 2 skill sets within a simulation-based environment and (2) assess if certain nontechnical skill components are of particular relevance to technical performance. A prospective analysis of data acquired from a comparative study of simulation vs nonsimulation training was conducted. Half of the participants underwent training of technical and nontechnical skills within ureteroscopy, with the remaining half undergoing no training. All were assessed within a full immersion environment against both technical (time to completion, Objective Structured Assessment of Technical Skills, and task-specific checklist scores) and nontechnical parameters (Nontechnical Skills for Surgeons [NOTSS] rating scale). The data of whole and individual cohorts were analyzed using Pearson correlation coefficient. The trial took place within the Simulation and Interactive Learning Centre at Guy's Hospital, London, UK. In total, 32 novice participants with no prior practical ureteroscopy experience were included within the data analysis. A correlation was found within all outcome measures analyzed. For the whole cohort, a strong negative correlation was found between time to completion and NOTSS scores (r = -0.75, p < 0.001), with strong positive correlations identified when NOTSS scores were compared with Objective Structured Assessment of Technical Skills (r = 0.89, p < 0.001) and task-specific checklist scores (r = 0.91, p < 0.001). Similar results were observed when each cohort was analyzed separately. Finally, all individual nontechnical skill components demonstrated a strong correlation with all technical skill parameters, regardless of training. A strong correlation between technical and nontechnical performance exists, which was demonstrated to be irrespective of training received. This may suggest an inherent link between skill sets. Furthermore, all nontechnical skill sets are important in technical performance. This supports the notion that both of these skills should be trained and assessed together within 1 curriculum. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  3. APPLICATIONS ANALYSIS REPORT: BABCOCK AND WILCOX CYCLONE FURNACE

    EPA Science Inventory

    This document is an evaluation of the performance of the Babcock & Wilcox (B&W) Cyclone Furnace Vitrification Technology and its applicability as a treatment technique for soils contaminated with heavy metals, radionuclides, and organics. oth the technical and economic aspects of...

  4. EPOC WATER INC. MICROFILTRATION TECHNOLOGY - APPLICATIONS ANALYSIS REPORT

    EPA Science Inventory

    This document is an evaluation of the performance of the EPOC Water, Inc. Microfiltration Technology and its applicability as a treatment technique for water contaminated with metals. oth the technical aspects arid the economics of this technology were examined. Operational data ...

  5. FY71 Engineering Report on Surveillance Techniques for Civil Aviation Security

    DOT National Transportation Integrated Search

    1971-11-01

    This document discusses the work performed by the TSC task group on surveillance techniques in FY71. The principal section is devoted to the technical description, classification and evaluation of commercial metal detectors for concealed weapons. It ...

  6. Development and performance evaluation of fiber reinforced polymer bridge : [technical summary].

    DOT National Transportation Integrated Search

    2014-03-01

    Conventionally, highway bridge decks in the US are predominantly made of steel-reinforced concrete. However, repair and : maintenance costs of these bridges incurred at the federal and state levels are overwhelming. As a result, for many years, there...

  7. APPLICATION ANALYSIS REPORT: RETECH PLASMA CENTRIFUGAL FURNACE

    EPA Science Inventory

    This document is an evaluation of the performance of the Retech, Inc. Plasma Centrifugal Furnace (PCF) and its applicability as a treatment for soils contaminated with organic and/or inorganic compounds. Both the technical and economic aspectsof the technology were examined. A...

  8. NREL Evaluates Performance of Fast-Charge Electric Buses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2016-09-16

    This real-world performance evaluation is designed to enhance understanding of the overall usage and effectiveness of electric buses in transit operation and to provide unbiased technical information to other agencies interested in adding such vehicles to their fleets. Initial results indicate that the electric buses under study offer significant fuel and emissions savings. The final results will help Foothill Transit optimize the energy-saving potential of its transit fleet. NREL's performance evaluations help vehicle manufacturers fine-tune their designs and help fleet managers select fuel-efficient, low-emission vehicles that meet their bottom line and operational goals. help Foothill Transit optimize the energy-saving potentialmore » of its transit fleet. NREL's performance evaluations help vehicle manufacturers fine-tune their designs and help fleet managers select fuel-efficient, low-emission vehicles that meet their bottom line and operational goals.« less

  9. The relative contribution of physical fitness to the technical execution score in youth rhythmic gymnastics.

    PubMed

    Donti, Olyvia; Bogdanis, Gregory C; Kritikou, Maria; Donti, Anastasia; Theodorakou, Kalliopi

    2016-06-01

    This study examined the association between physical fitness and a technical execution score in rhythmic gymnasts varying in the performance level. Forty-six young rhythmic gymnasts (age: 9.9 ±1.3 years) were divided into two groups (qualifiers, n=24 and non-qualifiers, n=22) based on the results of the National Championships. Gymnasts underwent a series of physical fitness tests and technical execution was evaluated in a routine without apparatus. There were significant differences between qualifiers and non-qualifiers in the technical execution score (p=0.01, d=1.0), shoulder flexion (p=0.01, d=0.8), straight leg raise (p=0.004, d=0.9), sideways leg extension (p=0.002, d=0.9) and body fat (p=.021, d=0.7), but no differences were found in muscular endurance and jumping performance. The technical execution score for the non-qualifiers was significantly correlated with shoulder extension (r=0.423, p<0.05), sideways leg extension (r=0.687, p<0.01), push ups (r=0.437, p<0.05) and body fat (r=0.642, p<0.01), while there was only one significant correlation with sideways leg extension (r=0.467, p<0.05) for the qualifiers. Multiple regression analysis revealed that sideways leg extension, body fat, and push ups accounted for a large part (62.9%) of the variance in the technical execution score for the non-qualifiers, while for the qualifiers, only 37.3% of the variance in the technical execution score was accounted for by sideways leg extension and spine flexibility. In conclusion, flexibility and body composition can effectively discriminate between qualifiers and non-qualifiers in youth rhythmic gymnastics. At the lower level of performance (non-qualifiers), physical fitness seems to have a greater effect on the technical execution score.

  10. A Curriculum Evaluation Study of Commercial Art Programs in the Wisconsin Vocational, Technical and Adult Schools: Final Report.

    ERIC Educational Resources Information Center

    Crandall, William H.; Niesl, Joseph

    A study of 2-year associate degree commercial arts programs in Wisconsin was conducted to determine the entry-level job requirements of commercial artists on a statewide basis; to identify skill tasks, performance levels, and learning experiences required of commercial artists; to evaluate the relevance of 2-year programs to industry requirements;…

  11. 7 CFR Exhibit B to Subpart I of... - Evaluation Report of Self-Help Technical Assistance (TA) Grants

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 13 2014-01-01 2013-01-01 true Evaluation Report of Self-Help Technical Assistance... Self-Help Technical Assistance Grants Pt. 1944, Subpt. I, Exh. B Exhibit B to Subpart I of Part 1944—Evaluation Report of Self-Help Technical Assistance (TA) Grants Evaluation for Quarter Ending:(1...

  12. 7 CFR Exhibit B to Subpart I of... - Evaluation Report of Self-Help Technical Assistance (TA) Grants

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 13 2012-01-01 2012-01-01 false Evaluation Report of Self-Help Technical Assistance... Self-Help Technical Assistance Grants Pt. 1944, Subpt. I, Exh. B Exhibit B to Subpart I of Part 1944—Evaluation Report of Self-Help Technical Assistance (TA) Grants Evaluation for Quarter Ending:(1...

  13. 7 CFR Exhibit B to Subpart I of... - Evaluation Report of Self-Help Technical Assistance (TA) Grants

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 13 2013-01-01 2013-01-01 false Evaluation Report of Self-Help Technical Assistance... Self-Help Technical Assistance Grants Pt. 1944, Subpt. I, Exh. B Exhibit B to Subpart I of Part 1944—Evaluation Report of Self-Help Technical Assistance (TA) Grants Evaluation for Quarter Ending:(1...

  14. Development and evaluation of the Stingray, an amphibious maritime interdiction operations unmanned ground vehicle

    NASA Astrophysics Data System (ADS)

    Nguyen, Hoa G.; Castelli, Robin

    2014-06-01

    The U.S. Navy and Marine Corps conduct thousands of Maritime Interdiction Operations (MIOs) every year around the globe. Navy Visit, Board, Search, and Seizure (VBSS) teams regularly board suspect ships and perform search operations, often in hostile environments. There is a need for a small tactical robot that can be deployed ahead of the team to provide enhanced situational awareness in these boarding, breaching, and clearing operations. In 2011, the Space and Naval Warfare Systems Center Pacific conducted user evaluations on a number of small throwable robots and sensors, verified the requirements, and developed the key performance parameters (KPPs) for an MIO robot. Macro USA Corporation was then tasked to design and develop two prototype systems, each consisting of one control/display unit and two small amphibious Stingray robots. Technical challenges included the combination paddle wheel/shock-absorbing wheel, the tradeoff between impact resistance, size, and buoyancy, and achieving adequate traction on wet surfaces. This paper describes the technical design of these robots and the results of subsequent user evaluations by VBSS teams.

  15. Strengthening and sustainability of national immunization technical advisory groups (NITAGs) globally: Lessons and recommendations from the founding meeting of the global NITAG network.

    PubMed

    Adjagba, Alex; MacDonald, Noni E; Ortega-Pérez, Inmaculada; Duclos, Philippe

    2017-05-25

    National Immunization Technical Advisory Groups (NITAGs) provide independent, evidence-informed advice to assist their governments in immunization policy formation. However, many NITAGs face challenges in fulfilling their roles. Hence the many requests for formation of a network linking NITAGs together so they can learn from each other. To address this request, the Health Policy and Institutional Development (HPID) Center (a WHO Collaborating Center at the Agence de Médecine Préventive - AMP), in collaboration with WHO, organized a meeting in Veyrier-du-Lac, France, on 11 and 12 May 2016, to establish a Global NITAG Network (GNN). The meeting focused on two areas: the requirements for (a) the establishment of a global NITAG collaborative network; and (b) the global assessment/evaluation of the performance of NITAGs. 35 participants from 26 countries reviewed the proposed GNN framework documents and NITAG performance evaluation. Participants recommended that a GNN should be established, agreed on its governance, function, scope and a proposed work plan as well as setting a framework for NITAG evaluation. Copyright © 2017.

  16. Rising to the Challenge: Acute Stress Appraisals and Selection Centre Performance in Applicants to Postgraduate Specialty Training in Anaesthesia

    ERIC Educational Resources Information Center

    Roberts, Martin J.; Gale, Thomas C. E.; McGrath, John S.; Wilson, Mark R.

    2016-01-01

    The ability to work under pressure is a vital non-technical skill for doctors working in acute medical specialties. Individuals who evaluate potentially stressful situations as challenging rather than threatening may perform better under pressure and be more resilient to stress and burnout. Training programme recruitment processes provide an…

  17. Assessment Alternatives for a High Skill MOS. Volume I. Problem Procedures and Results. Volume II. Appendices.

    ERIC Educational Resources Information Center

    Frederickson, Edward W.; And Others

    The development and evaluation of prototype hands-on equipment, job sample performance tests for a high skilled technical Military Occupational Specialty (MOS) are described. An electronic maintenance MOS (26C20) was used as the research vehicle. The results led to the conclusion that valid and reliable performance tests could be constructed, but…

  18. Breaking Ground: Analysis of the Assessment System and Impact of Mexico's Teacher Incentive Program "Carrera Magisterial." Technical Report. Summary

    ERIC Educational Resources Information Center

    Santibariz, Lucrecia; Martinez, Jose Felipe; Datar, Ashlesha; McEwan, Patrick J.; Setodji, Claude Messan; Basurto-Davilao, Ricardo

    2007-01-01

    Mexico's Carrera Magisterial was instituted in 1992 and designed jointly by the federal education authorities, state authorities, and the teachers' union as a horizontal promotion system that rewards teachers with salary bonuses on the basis of their performance. Teacher performance is evaluated through a series of assessments, including teacher…

  19. The philosophy of benchmark testing a standards-based picture archiving and communications system.

    PubMed

    Richardson, N E; Thomas, J A; Lyche, D K; Romlein, J; Norton, G S; Dolecek, Q E

    1999-05-01

    The Department of Defense issued its requirements for a Digital Imaging Network-Picture Archiving and Communications System (DIN-PACS) in a Request for Proposals (RFP) to industry in January 1997, with subsequent contracts being awarded in November 1997 to the Agfa Division of Bayer and IBM Global Government Industry. The Government's technical evaluation process consisted of evaluating a written technical proposal as well as conducting a benchmark test of each proposed system at the vendor's test facility. The purpose of benchmark testing was to evaluate the performance of the fully integrated system in a simulated operational environment. The benchmark test procedures and test equipment were developed through a joint effort between the Government, academic institutions, and private consultants. Herein the authors discuss the resources required and the methods used to benchmark test a standards-based PACS.

  20. Neurosurgical Skills Assessment: Measuring Technical Proficiency in Neurosurgery Residents Through Intraoperative Video Evaluations.

    PubMed

    Sarkiss, Christopher A; Philemond, Steven; Lee, James; Sobotka, Stanislaw; Holloway, Terrell D; Moore, Maximillian M; Costa, Anthony B; Gordon, Errol L; Bederson, Joshua B

    2016-05-01

    Although technical skills are fundamental in neurosurgery, there is little agreement on how to describe, measure, or compare skills among surgeons. The primary goal of this study was to develop a quantitative grading scale for technical surgical performance that distinguishes operator skill when graded by domain experts (residents, attendings, and nonsurgeons). Scores provided by raters should be highly reliable with respect to scores from other observers. Neurosurgery residents were fitted with a head-mounted video camera while performing craniotomies under attending supervision. Seven videos, 1 from each postgraduate year (PGY) level (1-7), were anonymized and scored by 16 attendings, 8 residents, and 7 nonsurgeons using a grading scale. Seven skills were graded: incision, efficiency of instrument use, cauterization, tissue handling, drilling/craniotomy, confidence, and training level. A strong correlation was found between skills score and PGY year (P < 0.001, analysis of variance). Junior residents (PGY 1-3) had significantly lower scores than did senior residents (PGY 4-7, P < 0.001, t test). Significant variation among junior residents was observed, and senior residents' scores were not significantly different from one another. Interrater reliability, measured against other observers, was high (r = 0.581 ± 0.245, Spearman), as was assessment of resident training level (r = 0.583 ± 0.278, Spearman). Both variables were strongly correlated (r = 0.90, Pearson). Attendings, residents, and nonsurgeons did not score differently (P = 0.46, analysis of variance). Technical skills of neurosurgery residents recorded during craniotomy can be measured with high interrater reliability. Surgeons and nonsurgeons alike readily distinguish different skill levels. This type of assessment could be used to coach residents, to track performance over time, and potentially to compare skill levels. Developing an objective tool to evaluate surgical performance would be useful in several areas of neurosurgery education. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Relationship between non-technical skills and technical performance during cardiopulmonary resuscitation: does stress have an influence?

    PubMed

    Krage, Ralf; Zwaan, Laura; Tjon Soei Len, Lian; Kolenbrander, Mark W; van Groeningen, Dick; Loer, Stephan A; Wagner, Cordula; Schober, Patrick

    2017-11-01

    Non-technical skills, such as task management, leadership, situational awareness, communication and decision-making refer to cognitive, behavioural and social skills that contribute to safe and efficient team performance. The importance of these skills during cardiopulmonary resuscitation (CPR) is increasingly emphasised. Nonetheless, the relationship between non-technical skills and technical performance is poorly understood. We hypothesise that non-technical skills become increasingly important under stressful conditions when individuals are distracted from their tasks, and investigated the relationship between non-technical and technical skills under control conditions and when external stressors are present. In this simulator-based randomised cross-over study, 30 anaesthesiologists and anaesthesia residents from the VU University Medical Center, Amsterdam, the Netherlands, participated in two different CPR scenarios in random order. In one scenario, external stressors (radio noise and a distractive scripted family member) were added, while the other scenario without stressors served as control condition. Non-technical performance of the team leader and technical performance of the team were measured using the 'Anaesthetists' Non-technical Skill' score and a recently developed technical skills score. Analysis of variance and Pearson correlation coefficients were used for statistical analyses. Non-technical performance declined when external stressors were present (adjusted mean difference 3.9 points, 95% CI 2.4 to 5.5 points). A significant correlation between non-technical and technical performance scores was observed when external stressors were present (r=0.67, 95% CI 0.40 to 0.83, p<0.001), while no evidence for such a relationship was observed under control conditions (r=0.15, 95% CI -0.22 to 0.49, p=0.42). This was equally true for all individual domains of the non-technical performance score (task management, team working, situation awareness, decision-making). During CPR with external stressors, the team's technical performance is related to the non-technical skills of the team leader. This may have important implications for training of CPR teams. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. Relationship between non-technical skills and technical performance during cardiopulmonary resuscitation: does stress have an influence?

    PubMed Central

    Krage, Ralf; Zwaan, Laura; Tjon Soei Len, Lian; Kolenbrander, Mark W; van Groeningen, Dick; Loer, Stephan A; Wagner, Cordula; Schober, Patrick

    2017-01-01

    Background Non-technical skills, such as task management, leadership, situational awareness, communication and decision-making refer to cognitive, behavioural and social skills that contribute to safe and efficient team performance. The importance of these skills during cardiopulmonary resuscitation (CPR) is increasingly emphasised. Nonetheless, the relationship between non-technical skills and technical performance is poorly understood. We hypothesise that non-technical skills become increasingly important under stressful conditions when individuals are distracted from their tasks, and investigated the relationship between non-technical and technical skills under control conditions and when external stressors are present. Methods In this simulator-based randomised cross-over study, 30 anaesthesiologists and anaesthesia residents from the VU University Medical Center, Amsterdam, the Netherlands, participated in two different CPR scenarios in random order. In one scenario, external stressors (radio noise and a distractive scripted family member) were added, while the other scenario without stressors served as control condition. Non-technical performance of the team leader and technical performance of the team were measured using the ‘Anaesthetists’ Non-technical Skill’ score and a recently developed technical skills score. Analysis of variance and Pearson correlation coefficients were used for statistical analyses. Results Non-technical performance declined when external stressors were present (adjusted mean difference 3.9 points, 95% CI 2.4 to 5.5 points). A significant correlation between non-technical and technical performance scores was observed when external stressors were present (r=0.67, 95% CI 0.40 to 0.83, p<0.001), while no evidence for such a relationship was observed under control conditions (r=0.15, 95% CI −0.22 to 0.49, p=0.42). This was equally true for all individual domains of the non-technical performance score (task management, team working, situation awareness, decision-making). Conclusions During CPR with external stressors, the team’s technical performance is related to the non-technical skills of the team leader. This may have important implications for training of CPR teams. PMID:28844039

  3. Advanced training of specialists in area of fiber-optic communication lines maintenance

    NASA Astrophysics Data System (ADS)

    Andreev, Vladimir A.; Voronkov, Andrey A.; Bukashkin, Sergey A.; Buzova, Maria A.

    2017-04-01

    The paper considers the concept of fiber-optic communication lines (FOCL) maintenance. Performance criterion of FOCL technical maintenance was proposed. For the first time the algorithm for evaluation of the FOCL maintenance efficiency at telecommunication specialists training was applied.

  4. Sugar cane fiber geotextiles : production, evaluation, and field study : technical summary.

    DOT National Transportation Integrated Search

    1996-08-01

    The sugar cane fiber geotexiles performed as well as the commercial products and exhibited grass propagation and slope protection equivalent to other products. Sugar cane fiber mats were superior in conformation to the slope even after heavy rains. B...

  5. Development of speed models for improving travel forecasting and highway performance evaluation : [technical summary].

    DOT National Transportation Integrated Search

    2013-12-01

    Travel forecasting models predict travel demand based on the present transportation system and its use. Transportation modelers must develop, validate, and calibrate models to ensure that predicted travel demand is as close to reality as possible. Mo...

  6. Quantifying technical skills during open operations using video-based motion analysis.

    PubMed

    Glarner, Carly E; Hu, Yue-Yung; Chen, Chia-Hsiung; Radwin, Robert G; Zhao, Qianqian; Craven, Mark W; Wiegmann, Douglas A; Pugh, Carla M; Carty, Matthew J; Greenberg, Caprice C

    2014-09-01

    Objective quantification of technical operative skills in surgery remains poorly defined, although the delivery of and training in these skills is essential to the profession of surgery. Attempts to measure hand kinematics to quantify operative performance primarily have relied on electromagnetic sensors attached to the surgeon's hand or instrument. We sought to determine whether a similar motion analysis could be performed with a marker-less, video-based review, allowing for a scalable approach to performance evaluation. We recorded six reduction mammoplasty operations-a plastic surgery procedure in which the attending and resident surgeons operate in parallel. Segments representative of surgical tasks were identified with Multimedia Video Task Analysis software. Video digital processing was used to extract and analyze the spatiotemporal characteristics of hand movement. Attending plastic surgeons appear to use their nondominant hand more than residents when cutting with the scalpel, suggesting more use of countertraction. While suturing, attendings were more ambidextrous, with smaller differences in movement between their dominant and nondominant hands than residents. Attendings also seem to have more conservation of movement when performing instrument tying than residents, as demonstrated by less nondominant hand displacement. These observations were consistent within procedures and between the different attending plastic surgeons evaluated in this fashion. Video motion analysis can be used to provide objective measurement of technical skills without the need for sensors or markers. Such data could be valuable in better understanding the acquisition and degradation of operative skills, providing enhanced feedback to shorten the learning curve. Copyright © 2014 Mosby, Inc. All rights reserved.

  7. Improving Fatigue Performance of AHSS Welds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feng, Zhili; Yu, Xinghua; Erdman, III, Donald L.

    Reported herein is technical progress on a U.S. Department of Energy CRADA project with industry cost-share aimed at developing the technical basis and demonstrate the viability of innovative in-situ weld residual stresses mitigation technology that can substantially improve the weld fatigue performance and durability of auto-body structures. The developed technology would be costeffective and practical in high-volume vehicle production environment. Enhancing weld fatigue performance would address a critical technology gap that impedes the widespread use of advanced high-strength steels (AHSS) and other lightweight materials for auto body structure light-weighting. This means that the automotive industry can take full advantage ofmore » the AHSS in strength, durability and crashworthiness without the concern of the relatively weak weld fatigue performance. The project comprises both technological innovations in weld residual stress mitigation and due-diligence residual stress measurement and fatigue performance evaluation. Two approaches were investigated. The first one was the use of low temperature phase transformation (LTPT) weld filler wire, and the second focused on novel thermo-mechanical stress management technique. Both technical approaches have resulted in considerable improvement in fatigue lives of welded joints made of high-strength steels. Synchrotron diffraction measurement confirmed the reduction of high tensile weld residual stresses by the two weld residual stress mitigation techniques.« less

  8. Quantitative imaging biomarkers: a review of statistical methods for technical performance assessment.

    PubMed

    Raunig, David L; McShane, Lisa M; Pennello, Gene; Gatsonis, Constantine; Carson, Paul L; Voyvodic, James T; Wahl, Richard L; Kurland, Brenda F; Schwarz, Adam J; Gönen, Mithat; Zahlmann, Gudrun; Kondratovich, Marina V; O'Donnell, Kevin; Petrick, Nicholas; Cole, Patricia E; Garra, Brian; Sullivan, Daniel C

    2015-02-01

    Technological developments and greater rigor in the quantitative measurement of biological features in medical images have given rise to an increased interest in using quantitative imaging biomarkers to measure changes in these features. Critical to the performance of a quantitative imaging biomarker in preclinical or clinical settings are three primary metrology areas of interest: measurement linearity and bias, repeatability, and the ability to consistently reproduce equivalent results when conditions change, as would be expected in any clinical trial. Unfortunately, performance studies to date differ greatly in designs, analysis method, and metrics used to assess a quantitative imaging biomarker for clinical use. It is therefore difficult or not possible to integrate results from different studies or to use reported results to design studies. The Radiological Society of North America and the Quantitative Imaging Biomarker Alliance with technical, radiological, and statistical experts developed a set of technical performance analysis methods, metrics, and study designs that provide terminology, metrics, and methods consistent with widely accepted metrological standards. This document provides a consistent framework for the conduct and evaluation of quantitative imaging biomarker performance studies so that results from multiple studies can be compared, contrasted, or combined. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  9. Replacing fossil based plastic performance products by bio-based plastic products-Technical feasibility.

    PubMed

    van den Oever, Martien; Molenveld, Karin

    2017-07-25

    Larger scale market introduction of new bio-based products requires a clear advantage regarding sustainability, as well as an adequate techno-economic positioning relative to fossil based products. In a previous paper [Broeren et al., 2016], LCA results per kg and per functionality equivalent of bio-based plastics were presented, together with economic considerations. The present paper discusses the mechanical and thermal properties of a range of commercially available bio-based plastics based on polylactic acid (PLA), cellulose esters, starch and polyamides, and the feasibility of replacing fossil-based counterparts based on performance. The evaluation is approached from an end user perspective. First, potentially suitable bio-based plastics are selected based on manufacturers' specifications in technical data sheets, then a first experimental evaluation is performed on injection moulded ISO specimens, and finally a further selection of plastics is tested on large 50×70cm panels. This technical feasibility study indicates that so far bio-based plastics do not completely match the properties of high performance materials like flame retardant V-0 PC/ABS blends used in electronic devices. The performance gap is being decreased by the development of stereocomplex PLA and hybrid PLA blends with polycarbonate, which offer clearly improved properties with respect to maximum usage temperature and toughness. In addition, several materials meet the V-0 flammability requirements needed in specific durable applications. On the other hand, improving these properties so far has negative consequences for the bio-based content. This study also shows that replacement of bulk polymers like PS is feasible using PLA compounds with a bio-based content as high as 85%. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Cognitive training for technical and non-technical skills in robotic surgery: a randomised controlled trial.

    PubMed

    Raison, Nicholas; Ahmed, Kamran; Abe, Takashige; Brunckhorst, Oliver; Novara, Giacomo; Buffi, Nicolò; McIlhenny, Craig; van der Poel, Henk; van Hemelrijck, Mieke; Gavazzi, Andrea; Dasgupta, Prokar

    2018-05-07

    To investigate the effectiveness of motor imagery (MI) for technical skill and non-technical skill (NTS) training in minimally invasive surgery (MIS). A single-blind, parallel-group randomised controlled trial was conducted at the Vattikuti Institute of Robotic Surgery, King's College London. Novice surgeons were recruited by open invitation in 2015. After basic robotic skills training, participants underwent simple randomisation to either MI training or standard training. All participants completed a robotic urethrovesical anastomosis task within a simulated operating room. In addition to the technical task, participants were required to manage three scripted NTS scenarios. Assessment was performed by five blinded expert surgeons and a NTS expert using validated tools for evaluating technical skills [Global Evaluative Assessment of Robotic Skills (GEARS)] and NTS [Non-Technical Skills for Surgeons (NOTSS)]. Quality of MI was assessed using a revised Movement Imagery Questionnaire (MIQ). In all, 33 participants underwent MI training and 29 underwent standard training. Interrater reliability was high, Krippendorff's α = 0.85. After MI training, the mean (sd) GEARS score was significantly higher than after standard training, at 13.1 (3.25) vs 11.4 (2.97) (P = 0.03). There was no difference in mean NOTSS scores, at 25.8 vs 26.4 (P = 0.77). MI training was successful with significantly higher imagery scores than standard training (mean MIQ score 5.1 vs 4.5, P = 0.04). Motor imagery is an effective training tool for improving technical skill in MIS even in novice participants. No beneficial effect for NTS was found. © 2018 The Authors BJU International © 2018 BJU International Published by John Wiley & Sons Ltd.

  11. STDAC: Solar thermal design assistance center annual report fiscal year 1994

    NASA Astrophysics Data System (ADS)

    The Solar Thermal Design Assistance Center (STDAC) at Sandia is a resource provided by the DOE Solar Thermal Program. The STDAC's major objective is to accelerate the use of solar thermal systems by providing direct technical assistance to users in industry, government, and foreign countries; cooperating with industry to test, evaluate, and develop renewable energy systems and components; and educating public and private professionals, administrators, and decision makers. This FY94 report highlights the activities and accomplishments of the STDAC. In 1994, the STDAC continued to provide significant direct technical assistance to domestic and international organizations in industry, government, and education, Applying solar thermal technology to solve energy problems is a vital element of direct technical assistance. The STDAC provides information on the status of new, existing, and developing solar technologies; helps users screen applications; predicts the performance of components and systems; and incorporates the experience of Sandia's solar energy personnel and facilities to provide expert guidance. The STDAC directly enhances the US solar industry's ability to successfully bring improved systems to the marketplace. By collaborating with Sandia's Photovoltaic Design Assistance Center and the National Renewable Energy Laboratory the STDAC is able to offer each customer complete service in applying solar thermal technology. At the National Solar Thermal Test Facility the STDAC tests and evaluates new and innovative solar thermal technologies. Evaluations are conducted in dose cooperation with manufacturers, and the results are used to improve the product and/or quantify its performance characteristics. Manufacturers, in turn, benefit from the improved design, economic performance, and operation of their solar thermal technology. The STDAC provides cost sharing and in-kind service to manufacturers in the development and improvement of solar technology.

  12. The Reliability of Technical and Tactical Tagging Analysis Conducted by a Semi-Automatic VTS in Soccer.

    PubMed

    Beato, Marco; Jamil, Mikael; Devereux, Gavin

    2018-06-01

    The Video Tracking multiple cameras system (VTS) is a technology that records two-dimensional position data (x and y) at high sampling rates (over 25 Hz). The VTS is of great interest because it can record external load variables as well as collect technical and tactical parameters. Performance analysis is mainly focused on physical demands, yet less attention has been afforded to technical and tactical factors. Digital.Stadium® VTS is a performance analysis device widely used at national and international levels (i.e. Italian Serie A, Euro 2016) and the reliability evaluation of its technical tagging analysis (e.g. shots, passes, assists, set pieces) could be paramount for its application at elite level competitions, as well as in research studies. Two professional soccer teams, with 30 male players (age 23 ± 5 years, body mass 78.3 ± 6.9 kg, body height 1.81 ± 0.06 m), were monitored in the 2016 season during a friendly match and data analysis was performed immediately after the game ended. This process was then replicated a week later (4 operators conducted the data analysis in each week). This study reports a near perfect relationship between Match and its Replication. R2 coefficients (relationships between Match and Replication) were highly significant for each of the technical variables considered (p < 0.001). In particular, a high score of interclass correlation and a small coefficient of variation were reported. This study reports meaningless differences between Match and its Replication (intra-day reliability). We concluded that the semi-automatic process behind the Digital.Stadium® VTS was more than capable of recording technical tagging data accurately.

  13. Technical Packages in Injury and Violence Prevention to Move Evidence into Practice: Systematic Reviews and Beyond

    PubMed Central

    Haegerich, Tamara M.; David-Ferdon, Corinne; Noonan, Rita K.; Manns, Brian J.; Billie, Holly C.

    2016-01-01

    Injury and violence prevention strategies have greater potential for impact when they are based on scientific evidence. Systematic reviews of the scientific evidence can contribute key information about which policies and programs might have the greatest impact when implemented. However, systematic reviews have limitations, such as lack of implementation guidance and contextual information, that can limit the application of knowledge. “Technical packages,” developed by knowledge brokers such as the federal government, nonprofit agencies, and academic institutions, have the potential to be an efficient mechanism for making information from systematic reviews actionable. Technical packages provide information about specific evidence-based prevention strategies, along with the estimated costs and impacts, and include accompanying implementation and evaluation guidance to facilitate adoption, implementation, and performance measurement. We describe how systematic reviews can inform the development of technical packages for practitioners, provide examples of technical packages in injury and violence prevention, and explain how enhancing review methods and reporting could facilitate the use and applicability of scientific evidence. PMID:27604301

  14. State “Technical Assistance Programs” for nursing home quality improvement: variations and potential implications

    PubMed Central

    Li, Yue; Spector, Williams D.; Glance, Laurent G.; Mukamel, Dana B.

    2013-01-01

    Context To improve nursing home quality, many states developed “Technical Assistance Programs” that provide on-site consultation and training for nursing facility staff. Methods We conducted a national survey on these state programs to collect data on program design, operations, financing, and perceived effectiveness. Results As of 2010, 17 states have developed such programs. Compared to existing state nursing home quality regulations, these programs represent a collaborative, rather than enforcement-oriented, approach to quality. However, existing programs vary substantially in key structural features such as staffing patterns, funding levels, and relationship with state survey and certification agencies. Perceived effectiveness by program officials on quality was high, although few states have performed formal evaluations. Perceived barriers to program effectiveness included lack of appropriate staff and funding, among others. Conclusion State “Technical Assistance Programs” for nursing homes varies in program design and perceived effectiveness. Future comparative evaluations are needed to inform evidence-based quality initiatives. PMID:23216345

  15. Implementation Plan for Qualification of Sodium-Cooled Fast Reactor Technology Information

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moe, Wayne; Honma, George

    This document identifies and discusses implementation elements that can be used to facilitate consistent and systematic evaluation processes relating to quality attributes of technical information (with focus on SFR technology) that will be used to support licensing of advanced reactor designs. Information may include, but is not limited to, design documents for SFRs, research-and-development (R&D) data and associated documents, test plans and associated protocols, operations and test data, international research data, technical reports, and information associated with past U.S. Nuclear Regulatory Commission (NRC) reviews of SFR designs. The approach for determining acceptability of test data, analysis, and/or other technical informationmore » is based on guidance provided in INL/EXT-15-35805, “Guidance on Evaluating Historic Technology Information for Use in Advanced Reactor Licensing.” The implementation plan can be adopted into a working procedure at each of the national laboratories performing data qualification, or by applicants seeking future license application for advanced reactor technology.« less

  16. Ultrasound-Guided Percutaneous Tenotomy of Biceps Tendon: Technical Feasibility on Cadavers.

    PubMed

    Sconfienza, Luca Maria; Mauri, Giovanni; Messina, Carmelo; Aliprandi, Alberto; Secchi, Francesco; Sardanelli, Francesco; Randelli, Pietro Simone

    2016-10-01

    We tested the technical feasibility of ultrasound-guided percutaneous tenotomy of the long head of the biceps tendon (LHBT) in cadavers. Both shoulders of two fresh cadavers were scanned anteriorly to evaluate the extra-articular portion of the LHBT. Under ultrasound monitoring, a scalpel was advanced obliquely up to touch the superficial medial side of the LHBT, cutting it until the tendon was not visible anymore. Ultrasound evaluation was repeated after the procedure, and anatomic dissection was performed. The procedure was 100% feasible: four cuts were made to completely sever the tendon; the duration was less than 1 min. Skin incision measured 5 mm in two cases and 6 mm in two cases. Anatomic dissection confirmed complete tendon cut in all cases with proximal and distal tendon stumps very close to each other. Ultrasound-guided percutaneous LHBT tenotomy was 100% technically feasible in cadavers with a quick procedure and minimal cutaneous incision. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  17. Comparison of learning curves and skill transfer between classical and robotic laparoscopy according to the viewing conditions: implications for training.

    PubMed

    Blavier, Adélaïde; Gaudissart, Quentin; Cadière, Guy-Bernard; Nyssen, Anne-Sophie

    2007-07-01

    The purpose of this study was to evaluate the perceptual (2-dimensional [2D] vs. 3-dimensional [3D] view) and instrumental (classical vs. robotic) impacts of new robotic system on learning curves. Forty medical students without any surgical experience were randomized into 4 groups (classical laparoscopy with 3D-direct view or with 2D-indirect view, robotic system in 3D or in 2D) and repeated a laparoscopic task 6 times. After these 6 repetitions, they performed 2 trials with the same technique but in the other viewing condition (perceptive switch). Finally, subjects performed the last 3 trials with the technique they never used (technical switch). Subjects evaluated their performance answering a questionnaire (impressions of mastery, familiarity, satisfaction, self-confidence, and difficulty). Our study showed better performance and improvement in 3D view than in 2D view whatever the instrumental aspect. Participants reported less mastery, familiarity, and self-confidence and more difficulty in classical laparoscopy with 2D-indirect view than in the other conditions. Robotic surgery improves surgical performance and learning, particularly by 3D view advantage. However, perceptive and technical switches emphasize the need to adapt and pursue training also with traditional technology to prevent risks in conversion procedure.

  18. Orbital transfer vehicle concept definition and system analysis study. Volume 2: OTV concept definition and evaluation. Book 1: Mission and system requirements

    NASA Technical Reports Server (NTRS)

    Kofal, Allen E.

    1987-01-01

    The mission and system requirements for the concept definition and system analysis of the Orbital Transfer Vehicle (OTV) are established. The requirements set forth constitute the single authority for the selection, evaluation, and optimization of the technical performance and design of the OTV. This requirements document forms the basis for the Ground and Space Based OTV concept definition analyses and establishes the physical, functional, performance and design relationships to STS, Space Station, Orbital Maneuvering Vehicle (OMV), and payloads.

  19. The role of nontechnical skills in simulated trauma resuscitation.

    PubMed

    Briggs, Alexandra; Raja, Ali S; Joyce, Maurice F; Yule, Steven J; Jiang, Wei; Lipsitz, Stuart R; Havens, Joaquim M

    2015-01-01

    Trauma team training provides instruction on crisis management through debriefing and discussion of teamwork and leadership skills during simulated trauma scenarios. The effects of team leader's nontechnical skills (NTSs) on technical performance have not been thoroughly studied. We hypothesized that team's and team leader's NTSs correlate with technical performance of clinical tasks. Retrospective cohort study. Brigham and Women's Hospital, STRATUS Center for Surgical Simulation A total of 20 teams composed of surgical residents, emergency medicine residents, emergency department nurses, and emergency services assistants underwent 2 separate, high-fidelity, simulated trauma scenarios. Each trauma scenario was recorded on video for analysis and divided into 4 consecutive sections. For each section, 2 raters used the Non-Technical Skills for Surgeons framework to assess NTSs of the team. To evaluate the entire team's NTS, 2 additional raters used the Modified Non-Technical Skills Scale for Trauma system. Clinical performance measures including adherence to guidelines and time to perform critical tasks were measured independently. NTSs performance by both teams and team leaders in all NTS categories decreased from the beginning to the end of the scenario (all p < 0.05). There was significant correlation between team's and team leader's cognitive skills and critical task performance, with correlation coefficients between 0.351 and 0.478 (p < 0.05). The NTS performance of the team leader highly correlated with that of the entire team, with correlation coefficients between 0.602 and 0.785 (p < 0.001). The NTSs of trauma teams and team leaders deteriorate as clinical scenarios progress, and the performance of team leaders and teams is highly correlated. Cognitive NTS scores correlate with critical task performance. Increased attention to NTSs during trauma team training may lead to sustained performance throughout trauma scenarios. Decision making and situation awareness skills are critical for both team leaders and teams and should be specifically addressed to improve performance. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  20. 48 CFR 715.303-70 - Responsibilities of USAID evaluation committees.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... evaluation committees. A technical evaluation committee shall be established for each proposed procurement. In each case, the committee shall be composed of a chair representing the cognizant technical office... representatives from other concerned offices as appropriate. (b) Technical evaluation procedures. (1) The...

  1. Evaluation of the Hanford 200 West Groundwater Treatment System: Fluidized Bed Bioreactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Looney, Brian B.; Jackson, Dennis G.; Dickson, John O.

    A fluidized bed reactor (FBR) in the 200W water treatment facility at Hanford is removing nitrate from groundwater as part of the overall pump-treat-reinject process. Control of the FBR bed solids has proven challenging, impacting equipment, increasing operations and maintenance (O&M), and limiting the throughput of the facility. In response to the operational challenges, the Department of Energy Richland Office (DOE-RL) commissioned a technical assistance team to facilitate a system engineering evaluation and provide focused support recommendations to the Hanford Team. The DOE Environmental Management (EM) technical assistance process is structured to identify and triage technologies and strategies that addressmore » the target problem(s). The process encourages brainstorming and dialog and allows rapid identification and prioritization of possible options. Recognizing that continuous operation of a large-scale FBR is complex, requiring careful attention to system monitoring data and changing conditions, the technical assistance process focused on explicit identification of the available control parameters (“knobs”), how these parameters interact and impact the FBR system, and how these can be adjusted under different scenarios to achieve operational goals. The technical assistance triage process was performed in collaboration with the Hanford team.« less

  2. DOCUMENTATION OF STEPS TO ESTABLISH A TECHNICAL COLLEGE, AND THE EVALUATION OF "PERT" AS A PLANNING TOOL FOR EDUCATORS, PHASE I.

    ERIC Educational Resources Information Center

    MCKEE, ROBERT L.; RIDLEY, KATHRYN J.

    TO ESTABLISH A COLLEGE IN 100 DAYS PRESENTED AN OPPORTUNITY TO TEST THE VALUE OF PROGRAMED ORGANIZATIONAL PROCEDURES USING PROGRAM PERFORMANCE EVALUATION AND REVIEW TECHNIQUE (PERT) UNDER ACTUAL OPERATIONAL CONDITIONS, NOT IN A SIMULATED THEORETICAL SITUATION. THROUGH THE AID OF THE PERT PLANNING SYSTEM, IT WAS DETERMINED THAT THERE WERE NINE…

  3. Exploring the Capability of Evaluating Technical Solutions: A Collaborative Study into the Primary Technology Classroom

    ERIC Educational Resources Information Center

    Björkholm, Eva

    2014-01-01

    Within the field of technology education, evaluating technical solutions is considered as an important topic. Research indicates that pupils have difficulties in evaluating technical solutions in terms of fitness for purpose, i.e. how effective a technical solution supports its intended function. By using the learning study, which is an iterative…

  4. Let's get technical: Enhancing program evaluation through the use and integration of internet and mobile technologies.

    PubMed

    Materia, Frank T; Miller, Elizabeth A; Runion, Megan C; Chesnut, Ryan P; Irvin, Jamie B; Richardson, Cameron B; Perkins, Daniel F

    2016-06-01

    Program evaluation has become increasingly important, and information on program performance often drives funding decisions. Technology use and integration can help ease the burdens associated with program evaluation by reducing the resources needed (e.g., time, money, staff) and increasing evaluation efficiency. This paper reviews how program evaluators, across disciplines, can apply internet and mobile technologies to key aspects of program evaluation, which consist of participant registration, participant tracking and retention, process evaluation (e.g., fidelity, assignment completion), and outcome evaluation (e.g., behavior change, knowledge gain). In addition, the paper focuses on the ease of use, relative cost, and fit with populations. An examination on how these tools can be integrated to enhance data collection and program evaluation is discussed. Important limitations of and considerations for technology integration, including the level of technical skill, cost needed to integrate various technologies, data management strategies, and ethical considerations, are highlighted. Lastly, a case study of technology use in an evaluation conducted by the Clearinghouse for Military Family Readiness at Penn State is presented and illustrates how technology integration can enhance program evaluation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Procurement engineering - the productivity factor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bargerstock, S.B.

    1993-01-01

    The industry is several years on the road to implementation of the Nuclear Management and Resources Council (NUMARC) initiatives on commercial-grade item dedication and procurement. Utilities have taken several approaches to involve engineering in the procurement process. A common result for the approaches is the additional operations and maintenance (O M) cost imposed by the added resource requirements. Procurement engineering productivity is a key element in controlling this business area. Experience shows that 400 to 500% improvements in productivity are possible with a 2-yr period. Improving the productivity of the procurement engineering function is important in today's competitive utility environment.more » Procurement engineering typically involves four distinct technical evaluation responsibilities along with several administrative areas. Technical evaluations include the functionally based safety classification of replacement components and parts (lacking a master parts list), the determination of dedication requirements for safety-related commercial-grade items, the preparation of a procurement specification to maintain the licensed design bases, and the equivalency evaluation of alternate items not requiring the design-change process. Administrative duties include obtaining technical review of vendor-supplied documentation, identifying obsolete parts and components, resolving material nonconformances, initiating the design-change process for replacement items (as needed), and providing technical support to O M. Although most utilities may not perform or require all the noted activities, a large percentage will apply to each utility station.« less

  6. Technical Failure of MR Elastography Examinations of the Liver: Experience from a Large Single-Center Study.

    PubMed

    Wagner, Mathilde; Corcuera-Solano, Idoia; Lo, Grace; Esses, Steven; Liao, Joseph; Besa, Cecilia; Chen, Nelson; Abraham, Ginu; Fung, Maggie; Babb, James S; Ehman, Richard L; Taouli, Bachir

    2017-08-01

    Purpose To assess the determinants of technical failure of magnetic resonance (MR) elastography of the liver in a large single-center study. Materials and Methods This retrospective study was approved by the institutional review board. Seven hundred eighty-one MR elastography examinations performed in 691 consecutive patients (mean age, 58 years; male patients, 434 [62.8%]) in a single center between June 2013 and August 2014 were retrospectively evaluated. MR elastography was performed at 3.0 T (n = 443) or 1.5 T (n = 338) by using a gradient-recalled-echo pulse sequence. MR elastography and anatomic image analysis were performed by two observers. Additional observers measured liver T2* and fat fraction. Technical failure was defined as no pixel value with a confidence index higher than 95% and/or no apparent shear waves imaged. Logistic regression analysis was performed to assess potential predictive factors of technical failure of MR elastography. Results The technical failure rate of MR elastography at 1.5 T was 3.5% (12 of 338), while it was higher, 15.3% (68 of 443), at 3.0 T. On the basis of univariate analysis, body mass index, liver iron deposition, massive ascites, use of 3.0 T, presence of cirrhosis, and alcoholic liver disease were all significantly associated with failure of MR elastography (P < .004); but on the basis of multivariable analysis, only body mass index, liver iron deposition, massive ascites, and use of 3.0 T were significantly associated with failure of MR elastography (P < .004). Conclusion The technical failure rate of MR elastography with a gradient-recalled-echo pulse sequence was low at 1.5 T but substantially higher at 3.0 T. Massive ascites, iron deposition, and high body mass index were additional independent factors associated with failure of MR elastography of the liver with a two-dimensional gradient-recalled-echo pulse sequence. © RSNA, 2017.

  7. 15 CFR 292.4 - Information infrastructure projects.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... customer base. The target customer base must be clearly defined and, in general, will be technical... evaluation for assessing outcomes of the activity, and “customer satisfaction” measures of performance. ... the customer base's needs within the proposed project area. The proposal should also show that the...

  8. EVALUATION OF ROTARY KILN INCINERATOR OPERATION AT LOW TO MODERATE TEMPERATURE CONDITIONS VOLUME 1. TECHNICAL RESULTS

    EPA Science Inventory

    A test program was performed at the Environmental Protection Agency Incineration Research Facility to study the effectiveness of incineration at low-to-moderate temperatures in decontaminating soils containing organic compounds with different volatilities (boiling points). The da...

  9. Evaluation of Fly Ash Quality Control Tools : Technical Summary

    DOT National Transportation Integrated Search

    2010-06-01

    Many entities currently use fl y ash in portland cement concrete (PCC) pavements and structures. Although : the body of knowledge is great concerning the use of fl y ash, several projects per year are subject to poor : performance where fl y ash is n...

  10. Evaluation of dowel bar alignment and effect on long-term performance of jointed concrete pavement.

    DOT National Transportation Integrated Search

    2013-09-01

    Recent concerns of misaligned dowel bars led to a technical assistance project : to investigate the roadways in question using a MIT-SCAN-2 device borrowed : from the Federal Highway Administration (FHWA). The device worked extremely : well, and the ...

  11. BERGMANN USA SOIL SEDIMENT WASHING TECHNOLOGY - APPLICATIONS ANALYSIS REPORT

    EPA Science Inventory

    This document provides an evaluation of the performance of the Bergmann USA Soil/Sediment Washing System and its applicability for the treatment of soils or sediments contaminated with organic and/or inorganic compounds. Both the technical and economic aspects of the technology w...

  12. 1995 Truck Size and Weight Performance-Based Workshop report : activity 5 : document North American and European experiences

    DOT National Transportation Integrated Search

    2012-08-01

    This report presents the test plan for conducting the Technical Capability Analysis for the United States Department of Transportation (U.S. DOT) evaluation of the San Diego Integrated Corridor Management (ICM) Initiative Demonstration. The ICM proje...

  13. Relationship between intraoperative non-technical performance and technical events in bariatric surgery.

    PubMed

    Fecso, A B; Kuzulugil, S S; Babaoglu, C; Bener, A B; Grantcharov, T P

    2018-03-30

    The operating theatre is a unique environment with complex team interactions, where technical and non-technical performance affect patient outcomes. The correlation between technical and non-technical performance, however, remains underinvestigated. The purpose of this study was to explore these interactions in the operating theatre. A prospective single-centre observational study was conducted at a tertiary academic medical centre. One surgeon and three fellows participated as main operators. All patients who underwent a laparoscopic Roux-en-Y gastric bypass and had the procedures captured using the Operating Room Black Box ® platform were included. Technical assessment was performed using the Objective Structured Assessment of Technical Skills and Generic Error Rating Tool instruments. For non-technical assessment, the Non-Technical Skills for Surgeons (NOTSS) and Scrub Practitioners' List of Intraoperative Non-Technical Skills (SPLINTS) tools were used. Spearman rank-order correlation and N-gram statistics were conducted. Fifty-six patients were included in the study and 90 procedural steps (gastrojejunostomy and jejunojejunostomy) were analysed. There was a moderate to strong correlation between technical adverse events (r s  = 0·417-0·687), rectifications (r s  = 0·380-0·768) and non-technical performance of the surgical and nursing teams (NOTSS and SPLINTS). N-gram statistics showed that after technical errors, events and prior rectifications, the staff surgeon and the scrub nurse exhibited the most positive non-technical behaviours, irrespective of operator (staff surgeon or fellow). This study demonstrated that technical and non-technical performances are related, on both an individual and a team level. Valuable data can be obtained around intraoperative errors, events and rectifications. © 2018 BJS Society Ltd Published by John Wiley & Sons Ltd.

  14. Spectral contents readout of birefringent sensor

    NASA Technical Reports Server (NTRS)

    Redner, Alex S.

    1989-01-01

    The technical objective of this research program was to develop a birefringent sensor, capable of measuring strain/stress up to 2000 F and a readout system based on Spectral Contents analysis. As a result of the research work, a data acquisition system was developed, capable of measuring strain birefringence in a sensor at 2000 F, with multi-point static and dynamic capabilities. The system uses a dedicated spectral analyzer for evaluation of stress-birefringence and a PC-based readout. Several sensor methods were evaluated. Fused silica was found most satisfactory. In the final evaluation, measurements were performed up to 2000 F and the system performance exceeded expectations.

  15. Integrating Safety and Mission Assurance into Systems Engineering Modeling Practices

    NASA Technical Reports Server (NTRS)

    Beckman, Sean; Darpel, Scott

    2015-01-01

    During the early development of products, flight, or experimental hardware, emphasis is often given to the identification of technical requirements, utilizing such tools as use case and activity diagrams. Designers and project teams focus on understanding physical and performance demands and challenges. It is typically only later, during the evaluation of preliminary designs that a first pass, if performed, is made to determine the process, safety, and mission quality assurance requirements. Evaluation early in the life cycle, though, can yield requirements that force a fundamental change in design. This paper discusses an alternate paradigm for using the concepts of use case or activity diagrams to identify safety hazard and mission quality assurance risks and concerns using the same systems engineering modeling tools being used to identify technical requirements. It contains two examples of how this process might be used in the development of a space flight experiment, and the design of a Human Powered Pizza Delivery Vehicle, along with the potential benefits to decrease development time, and provide stronger budget estimates.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Uller, Wibke, E-mail: wibke.uller@klinik.uni-regensburg.de; Knoppke, Birgit; Schreyer, Andreas G.

    Purpose: Evaluation of the efficacy and safety of percutaneous treatment of vascular stenoses and occlusions in pediatric liver transplant recipients. Methods: Fifteen children (mean age 8.3 years) underwent interventional procedures for 18 vascular complications after liver transplantation. Patients had stenoses or occlusions of portal veins (n = 8), hepatic veins (n = 3), inferior vena cava (IVC; n = 2) or hepatic arteries (n = 5). Technical and clinical success rates were evaluated. Results: Stent angioplasty was performed in seven cases (portal vein, hepatic artery and IVC), and sole balloon angioplasty was performed in eight cases. One child underwent thrombolysismore » (hepatic artery). Clinical and technical success was achieved in 14 of 18 cases of vascular stenoses or occlusions (mean follow-up 710 days). Conclusion: Pediatric interventional radiology allows effective and safe treatment of vascular stenoses after pediatric liver transplantation (PLT). Individualized treatment with special concepts for each pediatric patient is necessary. The variety, the characteristics, and the individuality of interventional management of all kinds of possible vascular stenoses or occlusions after PLT are shown.« less

  17. 48 CFR 2415.305 - Proposal evaluation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... technical portion of each proposal to the TEP Chairperson or his or her designee. The cost/price portion of each proposal shall be retained by the Contracting Officer pending initial technical evaluation by the TEP. (3) Technical evaluation. The TEP shall rate each proposal based on the evaluation factors...

  18. Land mobile communications in Ku-band - Results of a test campaign on Eutelsat I-F1

    NASA Astrophysics Data System (ADS)

    Dutronc, J.; Colcy, J. N.

    1990-02-01

    This paper discusses the results of technical tests on land mobile communications conducted in June and July 1989 in Europe using a Eutelsat satellite. The land-mobile communication system under test was that already operated by QUALCOMM in the U.S. under the registered name OmniTRACS. The aim of the field trial was to evaluate the technical characteristics of the system and test its performance in different operating conditions. The results establish the relationship between transmission performance (i.e. essentially the required number of transmission attempts in order to get a message through the communication channel), and the environment of the land mobile, the satellite transponder's mode of operations and the interference conditions.

  19. Technical evaluation of RETS-required reports for Browns Ferry Nuclear Power Station, Units 1, 2, and 3, for 1983

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Young, T.E.; Magleby, E.H.

    1985-09-06

    A review was performed of reports required by federal regulations and the plant-specific radiological effluent technical specifications (RETS) for operations conducted at Tennessee Valley Authority's Browns Ferry Nuclear Station, Units 1, 2, and 3, during 1983. The two periodic reports reviewed were (a) the Effluents and Waste Disposal Semiannual Report, First Half 1983 and (b) the Effluents and Waste Disposal Semiannual Report, Second Half 1983. The principal review guidelines were the plant's specific RETs and NRC guidance given in NUREG-0133, ''Preparation of Radiological Effluent Technical Specifications for Nuclear Power Plants.'' The Licensee's submitted reports were found to be reasonably completemore » and consistent with the review guidelines.« less

  20. Development of Reliable and Validated Tools to Evaluate Technical Resuscitation Skills in a Pediatric Simulation Setting: Resuscitation and Emergency Simulation Checklist for Assessment in Pediatrics.

    PubMed

    Faudeux, Camille; Tran, Antoine; Dupont, Audrey; Desmontils, Jonathan; Montaudié, Isabelle; Bréaud, Jean; Braun, Marc; Fournier, Jean-Paul; Bérard, Etienne; Berlengi, Noémie; Schweitzer, Cyril; Haas, Hervé; Caci, Hervé; Gatin, Amélie; Giovannini-Chami, Lisa

    2017-09-01

    To develop a reliable and validated tool to evaluate technical resuscitation skills in a pediatric simulation setting. Four Resuscitation and Emergency Simulation Checklist for Assessment in Pediatrics (RESCAPE) evaluation tools were created, following international guidelines: intraosseous needle insertion, bag mask ventilation, endotracheal intubation, and cardiac massage. We applied a modified Delphi methodology evaluation to binary rating items. Reliability was assessed comparing the ratings of 2 observers (1 in real time and 1 after a video-recorded review). The tools were assessed for content, construct, and criterion validity, and for sensitivity to change. Inter-rater reliability, evaluated with Cohen kappa coefficients, was perfect or near-perfect (>0.8) for 92.5% of items and each Cronbach alpha coefficient was ≥0.91. Principal component analyses showed that all 4 tools were unidimensional. Significant increases in median scores with increasing levels of medical expertise were demonstrated for RESCAPE-intraosseous needle insertion (P = .0002), RESCAPE-bag mask ventilation (P = .0002), RESCAPE-endotracheal intubation (P = .0001), and RESCAPE-cardiac massage (P = .0037). Significantly increased median scores over time were also demonstrated during a simulation-based educational program. RESCAPE tools are reliable and validated tools for the evaluation of technical resuscitation skills in pediatric settings during simulation-based educational programs. They might also be used for medical practice performance evaluations. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Technical and Economic Assessment of Span-Loaded Cargo Aircraft Concepts

    NASA Technical Reports Server (NTRS)

    1976-01-01

    The benefits are assessed of span distributed loading concepts as applied to future commercial air cargo operations. A two phased program is used to perform this assessment. The first phase consists of selected parametric studies to define significant configuration, performance, and economic trends. The second phase consists of more detailed engineering design, analysis, and economic evaluations to define the technical and economic feasibility of a selected spanloader design. A conventional all-cargo aircraft of comparable technology and size is used as a comparator system. The technical feasibility is demonstrated of the spanloader concept with no new major technology efforts required to implement the system. However, certain high pay-off technologies such as winglets, airfoil design, and advanced structural materials and manufacturing techniques need refinement and definition prior to application. In addition, further structural design analysis could establish the techniques and criteria necessary to fully capitalize upon the high degree of structural commonality and simplicity inherent in the spanloader concept.

  2. AFAL (Air Force Astronautics Laboratory) Technical Objective Document FY89.

    DTIC Science & Technology

    1987-12-01

    propellant manufacture that arc s Wu’ ’ " - applications. TITLE: Ultrasonic Nondestructive Evaluation fur Solid ’nu -! , c.. Performance Period: Jul 88...Develop and demonstrate a stabilizer system for (GAP propellants that provides protection equal to that achieved in HTPB propellants. Formulate GAP...monitoring equipment will be used to determine propagation and attenuation effects. 95 TITLE: Advanced Nuclear Propulsion Performance Period: Jan 89

  3. Repeated Kicking Actions in Karate: Effect on Technical Execution in Elite Practitioners.

    PubMed

    Quinzi, Federico; Camomilla, Valentina; Di Mario, Alberto; Felici, Francesco; Sbriccoli, Paola

    2016-04-01

    Training in martial arts is commonly performed by repeating a technical action continuously for a given number of times. This study aimed to investigate if the repetition of the task alters the proper technical execution, limiting the training efficacy for the technical evaluation during competition. This aim was pursued analyzing lower-limb kinematics and muscle activation during repeated roundhouse kicks. Six junior karate practitioners performed continuously 20 repetitions of the kick. Hip and knee kinematics and sEMG of vastus lateralis, biceps (BF), and rectus femoris were recorded. For each repetition, hip abduction-adduction and flexion-extension and knee flexion-extension peak angular displacements and velocities, agonist and antagonist muscle activation were computed. Moreover, to monitor for the presence of myoelectric fatigue, if any, the median frequency of the sEMG was computed. All variables were normalized with respect to their individual maximum observed during the sequence of kicks. Linear regressions were fitted to each normalized parameter to test its relationship with the repetition number. Linear-regression analysis showed that, during the sequence, the athletes modified their technique: Knee flexion, BF median frequency, hip abduction, knee-extension angular velocity, and BF antagonist activation significantly decreased. Conversely, hip flexion increased significantly. Since karate combat competitions require proper technical execution, training protocols combining severe fatigue and technical actions should be carefully proposed because of technique adaptations. Moreover, trainers and karate masters should consider including specific strength exercises for the BF and more generally for knee flexors.

  4. 75 FR 9608 - National Protection and Programs Directorate; Technical Assistance Request and Evaluation

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-03

    ... Directorate; Technical Assistance Request and Evaluation AGENCY: National Protection and Programs Directorate... assistance requests from each State and territory. OEC will use the Technical Assistance Evaluation Form to... electronically. Evaluation forms may be submitted electronically or in paper form. The Office of Management and...

  5. The Effect of Technical Assistance on Involvement and Use: The Case of a Research, Evaluation, and Technical Assistance Project

    ERIC Educational Resources Information Center

    Roseland, Denise; Volkov, Boris B.; Callow-Heusser, Catherine

    2011-01-01

    In contrast to typical National Science Foundation program evaluations, the Utah State Math Science Partnership-Research, Evaluation and Technical Assistance Project (MSP-RETA) provided technical assistance (TA) in two forms: direct TA for up to 10 projects a year, and professional development sessions for a larger number of project staff. Not…

  6. Crew Transportation Technical Standards and Design Evaluation Criteria

    NASA Technical Reports Server (NTRS)

    Lueders, Kathryn L.; Thomas, Rayelle E. (Compiler)

    2015-01-01

    Crew Transportation Technical Standards and Design Evaluation Criteria contains descriptions of technical, safety, and crew health medical processes and specifications, and the criteria which will be used to evaluate the acceptability of the Commercial Providers' proposed processes and specifications.

  7. Portal vein territory identification using indocyanine green fluorescence imaging: Technical details and short-term outcomes.

    PubMed

    Kobayashi, Yuta; Kawaguchi, Yoshikuni; Kobayashi, Kosuke; Mori, Kazuhiro; Arita, Junichi; Sakamoto, Yoshihiro; Hasegawa, Kiyoshi; Kokudo, Norihiro

    2017-12-01

    Portal vein (PV) territory identification during liver resection may be performed using indocyanine green (ICG) fluorescence imaging technique. However, the technical details of the fluorescence staining technique have not been fully elucidated. This study was performed to demonstrate the technical details of PV territory identification using fluorescence imaging and evaluates the short-term outcomes. From 2011 to 2015, 105 underwent liver resection at the University of Tokyo Hospital with one of the following fluorescence staining techniques by transhepatic PV injection or intravenous injection of ICG: single staining (n = 36), multiple staining (n = 31), counterstaining (n = 22), negative staining (n = 13), or paradoxical negative staining (n = 3). The PV territory was identified as a region with fluorescence or a defect of fluorescence using one of the five staining techniques. ICG was administered by transhepatic PV injection in all but the negative staining technique, which employed intravenous injection. No adverse events associated with the ICG administration occurred. The mortality, postoperative total morbidity, and the major complication (Clavien-Dindo grade ≥III) rates were 0.0%, 14.3%, and 7.6%. We have demonstrated the technical details of five types of fluorescence staining techniques. These techniques are safe to perform and facilitate clear visualization of the PV territory in real time, enhancing the efficacy of anatomical removal of such territories. © 2017 Wiley Periodicals, Inc.

  8. Technical Feasibility Aspects of the Geothermal Resource Reporting Methodology (GRRM)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Badgett, Alex; Young, Katherine R; Dobson, Patrick F.

    This paper reviews the technical assessment of the Geothermal Research Reporting Methodology (GRRM, http://en.openei.org/wiki/GRRM) being developed for reporting geothermal resources and project progress. The goal of the methodology is to provide the U.S. Department of Energy's Geothermal Technologies Office (GTO) with a consistent and comprehensible means of evaluating the impacts of its funding programs. The GRRM is designed to provide uniform assessment criteria for geothermal resource grades and developmental phases of geothermal resource exploration and development. This resource grade system provides information on twelve attributes of geothermal resource locations (e.g., temperature, permeability, land access) to indicate potential for geothermal development.more » The GTO plans to use these Protocols to help quantitatively identify the greatest barriers to geothermal development, develop measureable program goals that will have the greatest impact to geothermal deployment, objectively evaluate proposals based (in part) on a project's ability to contribute to program goals, monitor project progress, and report on GTO portfolio performance. The GRRM assesses three areas of geothermal potential: geological, socio-economic, and technical. Previous work and publications have discussed the work done on the geological aspects of this methodology (Young et al. 2015c); this paper details the development of the technical assessment of the GRRM. Technical development attributes considered include: reservoir management, drilling, logistics, and power conversion.« less

  9. The evaluation of small-sided games as a talent identification tool in highly trained prepubertal soccer players.

    PubMed

    Fenner, Jonathan S J; Iga, John; Unnithan, Viswanath

    2016-10-01

    The aim of this study was to evaluate physiological and technical attributes of prepubertal soccer players during multiple small-sided games (SSGs), and determine if SSGs can act as a talent identification tool. Sixteen highly trained U10 soccer players participated and separated into two groups of eight. Each group played six small-sided (4 vs. 4) matches of 5-min duration. Each player was awarded total points for the match result and goals scored. A game technical scoring chart was used to rate each player's performance during each game. Time-motion characteristics were measured using micromechanical devices. Total points had a very large significant relationship with game technical scoring chart (r = 0.758, P < 0.001). High-speed running distance had a significantly large correlation with game technical scoring chart (r = 0.547, P < 0.05). Total distance covered had a significant and moderate correlation with game technical scoring chart (r = 0.545, P < 0.05) and total points (r = 0.438, P < 0.05). The results demonstrated a large agreement between the highest-rated players and success in multiple SSGs, possibly due to higher-rated players covering larger distances in total and at high speed. Consequently, multiple SSG could be used to identify the more talented prepubertal soccer players.

  10. FRAMEWORK FOR RESPONSIBLE ENVIRONMENTAL DECISION-MAKING (FRED): USING LIFE CYCLE ASSESSMENT TO EVALUATE PREFERABILITY OF PRODUCTS

    EPA Science Inventory

    Framework for Responsible Environmental Decision-Making (FRED) demonstrates how the life-cycle concept can be used to quantify competing products' environmental performance so that this information may be integrated with considerations of total ownership cost and technical perfor...

  11. Validation of Welding Curriculum Manual.

    ERIC Educational Resources Information Center

    Stone, Sheila D.

    A study was conducted to validate the welding curriculum materials developed and published by the Oklahoma State Department of Vocational and Technical Education. Twelve instructors collected achievement data (unit tests, assignment sheets, and evaluation forms) concerning the performance of 280 students on a total of 46 instructional units. Item…

  12. Post-processing techniques to enhance reliability of assignment algorithm based performance measures : [technical summary].

    DOT National Transportation Integrated Search

    2011-01-01

    Travel demand modeling plays a key role in the transportation system planning and evaluation process. The four-step sequential travel demand model is the most widely used technique in practice. Traffic assignment is the key step in the conventional f...

  13. Mastering the art of public presentation: evaluation of agronomist and soil scientist

    USDA-ARS?s Scientific Manuscript database

    When the communication of scientific or technical information occurs in a public space, effective speakers follow a formula for content delivery. Participant observation of 11 presentations during a 2009 Field Day and content analysis of videotaped faculty and scientists’ oral performances generated...

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iguchi, Toshihiro, E-mail: iguchi@ba2.so-net.ne.jp; Hiraki, Takao, E-mail: takaoh@tc4.so-net.ne.jp; Gobara, Hideo, E-mail: gobara@cc.okayama-u.ac.jp

    PurposeThe aim of the study was to retrospectively evaluate simultaneous multiple hook wire placement outcomes before video-assisted thoracoscopic surgery (VATS).Materials and MethodsThirty-eight procedures were performed on 35 patients (13 men and 22 women; mean age, 59.9 years) with 80 lung lesions (mean diameter 7.9 mm) who underwent simultaneous multiple hook wire placements for preoperative localizations. The primary endpoints were technical success, complications, procedure duration, and VATS outcome; secondary endpoints included comparisons between technical success rates, complication rates, and procedure durations of the 238 single-placement procedures performed. Complications were also evaluated.ResultsIn 35 procedures including 74 lesions, multiple hook wire placements were technically successful;more » in the remaining three procedures, the second target placement was aborted because of massive pneumothorax after the first placement. Although complications occurred in 34 procedures, no grade 3 or above adverse event was observed. The mean procedure duration was 36.4 ± 11.8 min. Three hook wires dislodged during patient transport to the surgical suite. Seventy-four successfully marked lesions were resected. Six lesions without hook wires were successfully resected after detection by palpation with an additional mini-thoracotomy or using subtle pleural changes as a guide. The complication rates and procedure durations of multiple-placement procedures were significantly higher (P = 0.04) and longer (P < 0.001) than those in the single-placement group, respectively, while the technical success rate was not significantly different (P = 0.051).ConclusionsSimultaneous multiple hook wire placements before VATS were clinically feasible, but increased the complication rate and lengthened the procedure time.« less

  15. Evaluating Cross-Cutting Approaches to Chronic Disease Prevention and Management: Developing a Comprehensive Evaluation

    PubMed Central

    Jernigan, Jan; Barnes, Seraphine Pitt; Shea, Pat; Davis, Rachel; Rutledge, Stephanie

    2017-01-01

    We provide an overview of the comprehensive evaluation of State Public Health Actions to Prevent and Control Diabetes, Heart Disease, Obesity and Associated Risk Factors and Promote School Health (State Public Health Actions). State Public Health Actions is a program funded by the Centers for Disease Control and Prevention to support the statewide implementation of cross-cutting approaches to promote health and prevent and control chronic diseases. The evaluation addresses the relevance, quality, and impact of the program by using 4 components: a national evaluation, performance measures, state evaluations, and evaluation technical assistance to states. Challenges of the evaluation included assessing the extent to which the program contributed to changes in the outcomes of interest and the variability in the states’ capacity to conduct evaluations and track performance measures. Given the investment in implementing collaborative approaches at both the state and national level, achieving meaningful findings from the evaluation is critical. PMID:29215974

  16. Simulator-Based Angiography and Endovascular Neurosurgery Curriculum: A Longitudinal Evaluation of Performance Following Simulator-Based Angiography Training.

    PubMed

    Pannell, J Scott; Santiago-Dieppa, David R; Wali, Arvin R; Hirshman, Brian R; Steinberg, Jeffrey A; Cheung, Vincent J; Oveisi, David; Hallstrom, Jon; Khalessi, Alexander A

    2016-08-29

    This study establishes performance metrics for angiography and neuroendovascular surgery procedures based on longitudinal improvement in individual trainees with differing levels of training and experience. Over the course of 30 days, five trainees performed 10 diagnostic angiograms, coiled 10 carotid terminus aneurysms in the setting of subarachnoid hemorrhage, and performed 10 left middle cerebral artery embolectomies on a Simbionix Angio Mentor™ simulator. All procedures were nonconsecutive. Total procedure time, fluoroscopy time, contrast dose, heart rate, blood pressures, medications administered, packing densities, the number of coils used, and the number of stent-retriever passes were recorded. Image quality was rated, and the absolute value of technically unsafe events was recorded. The trainees' device selection, macrovascular access, microvascular access, clinical management, and the overall performance of the trainee was rated during each procedure based on a traditional Likert scale score of 1=fail, 2=poor, 3=satisfactory, 4=good, and 5=excellent. These ordinal values correspond with published assessment scales on surgical technique. After performing five diagnostic angiograms and five embolectomies, all participants demonstrated marked decreases in procedure time, fluoroscopy doses, contrast doses, and adverse technical events; marked improvements in image quality, device selection, access scores, and overall technical performance were additionally observed (p < 0.05). Similarly, trainees demonstrated marked improvement in technical performance and clinical management after five coiling procedures (p < 0.05). However, trainees with less prior experience deploying coils continued to experience intra-procedural ruptures up to the eighth embolization procedure; this observation likely corresponded with less tactile procedural experience to an exertion of greater force than appropriate for coil placement. Trainees across all levels of training and prior experience demonstrated a significant performance improvement after completion of our simulator curriculum consisting of five diagnostic angiograms, five embolectomy cases, and 10 aneurysm coil embolizations.

  17. Extended performance electric propulsion power processor design study. Volume 2: Technical summary

    NASA Technical Reports Server (NTRS)

    Biess, J. J.; Inouye, L. Y.; Schoenfeld, A. D.

    1977-01-01

    Electric propulsion power processor technology has processed during the past decade to the point that it is considered ready for application. Several power processor design concepts were evaluated and compared. Emphasis was placed on a 30 cm ion thruster power processor with a beam power rating supply of 2.2KW to 10KW for the main propulsion power stage. Extension in power processor performance were defined and were designed in sufficient detail to determine efficiency, component weight, part count, reliability and thermal control. A detail design was performed on a microprocessor as the thyristor power processor controller. A reliability analysis was performed to evaluate the effect of the control electronics redesign. Preliminary electrical design, mechanical design and thermal analysis were performed on a 6KW power transformer for the beam supply. Bi-Mod mechanical, structural and thermal control configurations were evaluated for the power processor and preliminary estimates of mechanical weight were determined.

  18. Evaluation and Information in the Field of Technical Aids for Disabled Persons: An European Perspective. Monograph Number Thirty-Five.

    ERIC Educational Resources Information Center

    Pedotti, Antonio, Ed.; Andrich, Renzo, Ed.

    The monograph provides information on evaluation of technical aids, wheelchairs, and computerized information systems for disabled persons. The first chapter provides a general overview of actions of the European Community concerning technical aids evaluation, information on the "Concerted Action" program called "Evaluation of…

  19. Patient-specific rehearsal prior to EVAR: a pilot study.

    PubMed

    Desender, L; Rancic, Z; Aggarwal, R; Duchateau, J; Glenck, M; Lachat, M; Vermassen, F; Van Herzeele, I

    2013-06-01

    This study aims to evaluate feasibility, face validity, influence on technical factors and subjective sense of utility of patient-specific rehearsal (PsR) prior to endovascular aortic aneurysm repair (EVAR). A prospective, multicentre pilot study. Patients suitable for EVAR were enrolled and a three-dimensional (3D) model of the patient's anatomy was generated. Less than 24 h prior to the real case, rehearsals were conducted in the laboratory or clinical angiosuite. Technical metrics were recorded during both procedures. A subjective questionnaire was used to evaluate realism, technical and human factor aspects (scale 1-5). Ten patients were enrolled. In one case, the treatment plan was altered based on PsR. In 7/9 patients, the rehearsal significantly altered the optimal C-arm position for the proximal landing zone and an identical fluoroscopy angle was chosen in the real procedure. All team members found the rehearsal useful for selecting the optimal fluoroscopy angle (median 4). The realism of the EVAR procedure simulation was rated highly (median 4). All team members found the PsR useful to prepare the individual team members and the entire team (median 4). PsR for EVAR permits creation of realistic case studies. Subjective evaluation indicates that it may influence optimal C-arm angles and be valuable to prepare the entire team. A randomised controlled trial (RCT) is planned to evaluate how this technology may influence technical and team performance, ultimately leading to improved patient safety. Copyright © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  20. Cost and Information Effectiveness Analysis (CIEA): A Methodology for Evaluating a Training Device Operational Readiness Assessment Capability (DORAC).

    DTIC Science & Technology

    1981-02-01

    Report 528 COST AIND I*FO•?JidTH ?i EFFECT•• ES1BS ANALYSIS (CDEA): A METiBLOBU Y FOR EVALUATIN1G A TRAINING DEMCE OPERATMDN1AL MAEA3 ],SE 3SSESS$ iElT ...8217, N. Within a military setting, the uses of training devices in performance evaluation have generally mirrored civilian uses and primarily...Technical Report 528 COST AND INFORMATION EFFECTIVENESS ANALYSIS (CIEA): A METHODOLOGY FOR EVALUATING A TRAINING DEVICE OPERATIONAL READINESS

  1. Design and evaluation of low-cost stainless steel fiberglass foam blades for large wind driven generating systems

    NASA Technical Reports Server (NTRS)

    Eggert, W. S.

    1982-01-01

    A low cost wind turbine blade based on a stainless steel fiberglass foam Budd blade design concept, was evaluated for its principle characteristics, low cost features, and its advantages and disadvantages. A blade structure was designed and construction methods and materials were selected. A complete blade tooling concepts, various technical and economic analysis, and evaluations of the blade design were performed. A comprehensive fatigue test program is conducted to provide data to verify the design stress allowables.

  2. Design and evaluation of low-cost stainless steel fiberglass foam blades for large wind driven generating systems

    NASA Astrophysics Data System (ADS)

    Eggert, W. S.

    1982-10-01

    A low cost wind turbine blade based on a stainless steel fiberglass foam Budd blade design concept, was evaluated for its principle characteristics, low cost features, and its advantages and disadvantages. A blade structure was designed and construction methods and materials were selected. A complete blade tooling concepts, various technical and economic analysis, and evaluations of the blade design were performed. A comprehensive fatigue test program is conducted to provide data to verify the design stress allowables.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hart, Darren M.

    Sandia National Laboratories has tested and evaluated Geotech Smart24 data acquisition system with active Fortezza crypto card data signing and authentication. The test results included in this report were in response to static and tonal-dynamic input signals. Most test methodologies used were based on IEEE Standards 1057 for Digitizing Waveform Recorders and 1241 for Analog to Digital Converters; others were designed by Sandia specifically for infrasound application evaluation and for supplementary criteria not addressed in the IEEE standards. The objective of this work was to evaluate the overall technical performance of the Geotech Smart24 digitizer with a Fortezza PCMCIA cryptomore » card actively implementing the signing of data packets. The results of this evaluation were compared to relevant specifications provided within manufacturer's documentation notes. The tests performed were chosen to demonstrate different performance aspects of the digitizer under test. The performance aspects tested include determining noise floor, least significant bit (LSB), dynamic range, cross-talk, relative channel-to-channel timing, time-tag accuracy, analog bandwidth and calibrator performance.« less

  4. Assessing the use of psychological skills by sports category and the relation with sports performance satisfaction.

    PubMed

    Tomé-Lourido, David; Arce, Constantino; Vales-Vázquez, Ángel; Ponte, Dolores

    2018-05-02

    The evaluation of psychological skills by athletes and their relationship with sports performance and satisfaction has been of great interest in recent decades. Likewise, there has been an emergent tendency to focus on developing specific psychological skills for each sport. The principal aim of this study was to determine the frequency with which athletes deploy psychological skills whilst competing and whether their frequency varies in accordance with the technical, tactical and physical characteristics of the sport in question. A further objective was to establish the connection between the frequency of use of psychological skills and athletes' degree of satisfaction with their performance. The study comprised 1003 athletes practising 43 different sports, grouped into 7 categories based on the similarities between them. Frequency of use of the psychological skills was measured with the Test of Performance Strategies 3. The data analyses allowed the following conclusions to be drawn: the degree to which psychological skills are used is dependent on the technical, tactical and physical characteristics of each sport; and the higher the frequency of the use of psychological skills, the greater the athletes' degree of satisfaction with their performance. These results allow athletes and coaches to increase levels of sports performance by working on the use of psychological skills, adapted to the technical, tactical or physical requirements of the category in which their sport is included. In addition, working on different psychological skills will improve their satisfaction with sports performance.

  5. Technical Stability and Biological Variability in MicroRNAs from Dried Blood Spots: A Lung Cancer Therapy-Monitoring Showcase.

    PubMed

    Kahraman, Mustafa; Laufer, Thomas; Backes, Christina; Schrörs, Hannah; Fehlmann, Tobias; Ludwig, Nicole; Kohlhaas, Jochen; Meese, Eckart; Wehler, Thomas; Bals, Robert; Keller, Andreas

    2017-09-01

    Different work flows have been proposed to use miRNAs as blood-borne biomarkers. In particular, the method used for collecting blood from patients can considerably influence the diagnostic results. We explored whether dried blood spots (DBSs) facilitate stable miRNA measurements and compared its technical stability with biological variability. First, we tested the stability of DBS samples by generating from 1 person 18 whole-genome-wide miRNA profiles of DBS samples that were exposed to different temperature and humidity conditions. Second, we investigated technical reproducibility by performing 7 replicates of DBS again from 1 person. Third, we investigated DBS samples from 53 patients with lung cancer undergoing different therapies. Across these 3 stages, 108 genome-wide miRNA profiles from DBS were generated and evaluated biostatistically. In the stability analysis, we observed that temperature and humidity had an overall limited influence on the miRNomes (average correlation between the different conditions of 0.993). Usage of a silica gel slightly diminished DBS' technical reproducibility. The 7 technical replicates had an average correlation of 0.996. The correlation with whole-blood PAXGene miRNomes of the same individual was remarkable (correlation of 0.88). Finally, evaluation of the samples from the 53 patients with lung cancer exposed to different therapies showed that the biological variations exceeded the technical variability significantly ( P < 0.0001), yielding 51 dysregulated miRNAs. We present a stable work flow for profiling of whole miRNomes on the basis of samples collected from DBS. Biological variations exceeded technical variations significantly. DBS-based miRNA profiles will potentially further the translational character of miRNA biomarker studies. © 2017 American Association for Clinical Chemistry.

  6. The Stanford Microsurgery and Resident Training (SMaRT) Scale: validation of an on-line global rating scale for technical assessment.

    PubMed

    Satterwhite, Thomas; Son, Ji; Carey, Joseph; Echo, Anthony; Spurling, Terry; Paro, John; Gurtner, Geoffrey; Chang, James; Lee, Gordon K

    2014-05-01

    We previously reported results of our on-line microsurgery training program, showing that residents who had access to our website significantly improved their cognitive and technical skills. In this study, we report an objective means for expert evaluators to reliably rate trainees' technical skills under the microscope, with the use of our novel global rating scale. "Microsurgery Essentials" (http://smartmicrosurgery.com) is our on-line training curriculum. Residents were randomly divided into 2 groups: 1 group reviewed this online resource and the other did not. Pre- and post-tests consisted of videotaped microsurgical sessions in which the trainee performed "microsurgery" on 3 different models: latex glove, penrose drain, and the dorsal vessel of a chicken foot. The SMaRT (Stanford Microsurgery and Resident Training) scale, consisting of 9 categories graded on a 5-point Likert scale, was used to assess the trainees. Results were analyzed with ANOVA and Student t test, with P less than 0.05 indicating statistical significance. Seventeen residents participated in the study. The SMaRT scale adequately differentiated the performance of more experienced senior residents (PGY-4 to PGY-6, total average score=3.43) from less experienced junior residents (PGY-1 to PGY-3, total average score=2.10, P<0.0001). Residents who viewed themselves as being confident received a higher score on the SMaRT scale (average score 3.5), compared to residents who were not as confident (average score 2.1) (P<0.001). There were no significant differences in scoring among all 3 evaluators (P>0.05). Additionally, junior residents who had access to our website showed a significant increase in their graded technical performance by 0.7 points when compared to residents who did not have access to the website who showed an improvement of only 0.2 points (P=0.01). Our SMaRT scale is valid and reliable in assessing the microsurgical skills of residents and other trainees. Current trainees are more likely to use self-directed on-line education because of its easy accessibility and interactive format. Our global rating scale can help ensure residents are achieving appropriate technical milestones.

  7. TurboTech Technical Evaluation Automated System

    NASA Technical Reports Server (NTRS)

    Tiffany, Dorothy J.

    2009-01-01

    TurboTech software is a Web-based process that simplifies and semiautomates technical evaluation of NASA proposals for Contracting Officer's Technical Representatives (COTRs). At the time of this reporting, there have been no set standards or systems for training new COTRs in technical evaluations. This new process provides boilerplate text in response to interview style questions. This text is collected into a Microsoft Word document that can then be further edited to conform to specific cases. By providing technical language and a structured format, TurboTech allows the COTRs to concentrate more on the actual evaluation, and less on deciding what language would be most appropriate. Since the actual word choice is one of the more time-consuming parts of a COTRs job, this process should allow for an increase in quantity of proposals evaluated. TurboTech is applicable to composing technical evaluations of contractor proposals, task and delivery orders, change order modifications, requests for proposals, new work modifications, task assignments, as well as any changes to existing contracts.

  8. A systematic evaluation of normalization methods in quantitative label-free proteomics.

    PubMed

    Välikangas, Tommi; Suomi, Tomi; Elo, Laura L

    2018-01-01

    To date, mass spectrometry (MS) data remain inherently biased as a result of reasons ranging from sample handling to differences caused by the instrumentation. Normalization is the process that aims to account for the bias and make samples more comparable. The selection of a proper normalization method is a pivotal task for the reliability of the downstream analysis and results. Many normalization methods commonly used in proteomics have been adapted from the DNA microarray techniques. Previous studies comparing normalization methods in proteomics have focused mainly on intragroup variation. In this study, several popular and widely used normalization methods representing different strategies in normalization are evaluated using three spike-in and one experimental mouse label-free proteomic data sets. The normalization methods are evaluated in terms of their ability to reduce variation between technical replicates, their effect on differential expression analysis and their effect on the estimation of logarithmic fold changes. Additionally, we examined whether normalizing the whole data globally or in segments for the differential expression analysis has an effect on the performance of the normalization methods. We found that variance stabilization normalization (Vsn) reduced variation the most between technical replicates in all examined data sets. Vsn also performed consistently well in the differential expression analysis. Linear regression normalization and local regression normalization performed also systematically well. Finally, we discuss the choice of a normalization method and some qualities of a suitable normalization method in the light of the results of our evaluation. © The Author 2016. Published by Oxford University Press.

  9. Experimental evaluation of thermal energy storage

    NASA Technical Reports Server (NTRS)

    Asbury, J. G.; Hersh, H. N.

    1980-01-01

    The technical performance of commercially available thermal energy storage (TES) residential heating units under severe weather conditions is discussed. The benefits and costs of TES to the user and utility companies were assessed. The TES issues, research and development needs, and barriers to commercialization were identified. The field tests which determined the performance characteristics for the TES are described and the TES systems, which included both ceramic and hydronic systems, are compared.

  10. STREAMLINED ENVIRONMENTAL LIFE-CYCLE ASSESSMENT: AN APPROACH FOR EVALUATING THE ENVIRONMENTAL PERFORMANCE OF BUILDING MATERIALS

    EPA Science Inventory

    The report presents the approach that was developed to prepare reports on building materials for the Environmental Resource Guide (ERG), both technical materials reports and applications reports. It also: (1) presents data collection tools that could be used to replicate material...

  11. 78 FR 75571 - Independent Assessment of the Process for the Review of Device Submissions; High Priority...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-12

    ... of performing the technical analysis, management assessment, and program evaluation tasks required to.... Analysis of elements of the review process (including the presubmission process, and investigational device... time to facilitate a more efficient process. This includes analysis of root causes for inefficiencies...

  12. Evaluation of surface resistivity measurements as an alternative to the rapid chloride permeability test for quality assurance and acceptance : technical summary.

    DOT National Transportation Integrated Search

    2011-07-01

    This project investigated the use of a surface resistivity device as an indication of concretes ability to resist chloride ion penetration for use in quality assurance (QA) and acceptance of high performance concrete (HPC). : The objectives of thi...

  13. Evaluation and long-term monitoring of the time-dependent characteristics of self-consolidating concrete in an instrumented Kansas prestressed concrete bridge : [technical summary].

    DOT National Transportation Integrated Search

    2014-01-01

    Construction of a new prestressed bridge with Self-Consolidating Concrete (SCC) : provided the opportunity to further study the time-dependent properties of SCC mix and : its long-term performance; considering the results and recommendations of previ...

  14. 76 FR 33307 - Strengthen and Promote the Role of Local Health Departments in Retail Food Safety Regulation (U-50)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-08

    ..., scientifically-based guidance, training, program evaluation, and technical assistance. B. Research/Cooperative... officials. NACCHO values guide staff and leadership in work to achieve optimal health for all through an... annual appropriations and successful performance. III. Paper Application, Registration, and Submission...

  15. Aeronautical Engineering: A continuing bibliography with indexes (supplement 188)

    NASA Technical Reports Server (NTRS)

    1985-01-01

    This bibliography lists 477 reports, articles and other documents introduced into the NASA scientific and technical information system in May 1985. The coverage includes documents on the engineering and theoretical aspects of design, construction, evaluation, testing, operation, and performance of aircraft (including aircraft engines) and associated components, equipment and systems.

  16. Technical note: A method for isolating glycogen granules from ruminal protozoa for further characterization

    USDA-ARS?s Scientific Manuscript database

    Evaluation of physical, compositional, and digestion characteristics of protozoal glycogen is best performed on a pure substrate in order to avoid interference from other cell components. A method for isolating protozoal glycogen without use of detergents was developed. Rumen inoculum was incubated ...

  17. Technical memo, project 0-6132 : task 6 - test sections in the districts.

    DOT National Transportation Integrated Search

    2011-01-01

    This Tech Memo presents a summary of the field performance evaluation of the TTI sections on US 59 in Panola County (Atlanta District) that was conducted at the end of summer on October 12th 2010; five months after HMA overlay placement. Field perfor...

  18. Curriculum Programs in Action, Their Administration and Evaluation; Report of a Conference Devoted to Description, Demonstration, and Evaluative Discussions of Innovative Programs in Vocational-Technical Education.

    ERIC Educational Resources Information Center

    San Francisco State Coll., CA. Center for Technological Education.

    The presentation, review and evaluation of innovative vocational-technical curriculums in operation was the major function of a San Francisco conference sponsored jointly by the Center for Technical Education at San Francisco State College and the Center for Studies in Vocational and Technical Education at the University of Wisconsin. Major…

  19. Emergency medicine resident crisis resource management ability: a simulation-based longitudinal study

    PubMed Central

    Clarke, Samuel; Horeczko, Timothy; Carlisle, Matthew; Barton, Joseph D.; Ng, Vivienne; Al-Somali, Sameerah; Bair, Aaron E.

    2014-01-01

    Background Simulation has been identified as a means of assessing resident physicians’ mastery of technical skills, but there is a lack of evidence for its utility in longitudinal assessments of residents’ non-technical clinical abilities. We evaluated the growth of crisis resource management (CRM) skills in the simulation setting using a validated tool, the Ottawa Crisis Resource Management Global Rating Scale (Ottawa GRS). We hypothesized that the Ottawa GRS would reflect progressive growth of CRM ability throughout residency. Methods Forty-five emergency medicine residents were tracked with annual simulation assessments between 2006 and 2011. We used mixed-methods repeated-measures regression analyses to evaluate elements of the Ottawa GRS by level of training to predict performance growth throughout a 3-year residency. Results Ottawa GRS scores increased over time, and the domains of leadership, problem solving, and resource utilization, in particular, were predictive of overall performance. There was a significant gain in all Ottawa GRS components between postgraduate years 1 and 2, but no significant difference in GRS performance between years 2 and 3. Conclusions In summary, CRM skills are progressive abilities, and simulation is a useful modality for tracking their development. Modification of this tool may be needed to assess advanced learners’ gains in performance. PMID:25499769

  20. Technical performance and match-to-match variation in elite football teams.

    PubMed

    Liu, Hongyou; Gómez, Miguel-Angel; Gonçalves, Bruno; Sampaio, Jaime

    2016-01-01

    Recent research suggests that match-to-match variation adds important information to performance descriptors in team sports, as it helps measure how players fine-tune their tactical behaviours and technical actions to the extreme dynamical environments. The current study aims to identify the differences in technical performance of players from strong and weak teams and to explore match-to-match variation of players' technical match performance. Performance data of all the 380 matches of season 2012-2013 in the Spanish First Division Professional Football League were analysed. Twenty-one performance-related match actions and events were chosen as variables in the analyses. Players' technical performance profiles were established by unifying count values of each action or event of each player per match into the same scale. Means of these count values of players from Top3 and Bottom3 teams were compared and plotted into radar charts. Coefficient of variation of each match action or event within a player was calculated to represent his match-to-match variation of technical performance. Differences in the variation of technical performances of players across different match contexts (team and opposition strength, match outcome and match location) were compared. All the comparisons were achieved by the magnitude-based inferences. Results showed that technical performances differed between players of strong and weak teams from different perspectives across different field positions. Furthermore, the variation of the players' technical performance is affected by the match context, with effects from team and opposition strength greater than effects from match location and match outcome.

  1. Using virtual robot-mediated play activities to assess cognitive skills.

    PubMed

    Encarnação, Pedro; Alvarez, Liliana; Rios, Adriana; Maya, Catarina; Adams, Kim; Cook, Al

    2014-05-01

    To evaluate the feasibility of using virtual robot-mediated play activities to assess cognitive skills. Children with and without disabilities utilized both a physical robot and a matching virtual robot to perform the same play activities. The activities were designed such that successfully performing them is an indication of understanding of the underlying cognitive skills. Participants' performance with both robots was similar when evaluated by the success rates in each of the activities. Session video analysis encompassing participants' behavioral, interaction and communication aspects revealed differences in sustained attention, visuospatial and temporal perception, and self-regulation, favoring the virtual robot. The study shows that virtual robots are a viable alternative to the use of physical robots for assessing children's cognitive skills, with the potential of overcoming limitations of physical robots such as cost, reliability and the need for on-site technical support. Virtual robots can provide a vehicle for children to demonstrate cognitive understanding. Virtual and physical robots can be used as augmentative manipulation tools allowing children with disabilities to actively participate in play, educational and therapeutic activities. Virtual robots have the potential of overcoming limitations of physical robots such as cost, reliability and the need for on-site technical support.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Leon E.; Conrad, Ryan C.; Keller, Daniel T.

    The International Atomic Energy Agency (IAEA) deploys unattended monitoring systems to provide continuous monitoring of nuclear material within safeguarded facilities around the world. As the number of unattended monitoring instruments increases, the IAEA is challenged to become more efficient in the implementation of those systems. In 2010, the IAEA initiated the Front-End Electronics for Unattended Measurement (FEUM) project with the goals of greater flexibility in the interfaces to various sensors and data acquisition systems, and improved capabilities for remotely located sensors (e.g., where sensor and front-end electronics might be separated by tens of meters). In consultation with the IAEA, amore » technical evaluation of a candidate FEUM device produced by a commercial vendor is being performed. This evaluation is assessing the device against the IAEA’s original technical specifications and a broad range of important parameters that included sensor types, cable types, and industrial electromagnetic noise that can degrade signals from remotely located detectors. Testing has been performed in a laboratory and also in environments representative of IAEA deployments. The results are expected to inform the IAEA about where and how FEUM devices might be implemented in the field. Data and preliminary findings from the testing performed to date are presented.« less

  3. The safety of magnetic resonance imaging in patients with programmable implanted intrathecal drug delivery systems: a 3-year prospective study.

    PubMed

    De Andres, Jose; Villanueva, Vicente; Palmisani, Stefano; Cerda-Olmedo, German; Lopez-Alarcon, Maria Dolores; Monsalve, Vicente; Minguez, Ana; Martinez-Sanjuan, Vicente

    2011-05-01

    It is common clinical practice to perform magnetic resonance imaging (MRI) in patients with indwelling programmable intrathecal drug delivery (IDD) systems, although the safety of the procedure has never been documented. We performed a single-center, 3-year, prospective evaluation in patients with a programmable implanted IDD to assess patient discomfort, IDD technical failures, and adverse effects during and after exposure to MRI. Forty-three consecutive patients with an implanted programmable IDD system (SynchroMed® EL Implantable Infusion Pump, Model 8626L-18, and SynchroMed® II Model 8637-20, 8637-40; Medtronic, Inc., Minneapolis, MN) requiring a scheduled MRI evaluation were studied during a 3-year period. All MRI scans were performed with a 1.5-tesla clinical use magnet and a specific absorption rate of no more than 0.9 W/kg. Radiograph control was used to confirm postexposure pump rotor movement and detect system dislocations. IDD system failures, patient satisfaction, and discomfort were recorded. None of the patients experienced signs of drug overinfusion that could lead to hemodynamic, respiratory, or neurologic alterations. Radiologic evaluation after MRI revealed no spatial displacements of the intrathecal catheter tip or body pump, and programmer telemetry confirmed the infusion recovery. Patients' satisfaction after the procedure was high. Performing an MRI scan with the proposed protocol in patients with an implanted Medtronic programmable IDD system resulted in virtually no technical or medical complications. © 2011 International Anesthesia Research Society

  4. Effect of obstetric team training on team performance and medical technical skills: a randomised controlled trial.

    PubMed

    Fransen, A F; van de Ven, J; Merién, A E R; de Wit-Zuurendonk, L D; Houterman, S; Mol, B W; Oei, S G

    2012-10-01

    To determine whether obstetric team training in a medical simulation centre improves the team performance and utilisation of appropriate medical technical skills of healthcare professionals. Cluster randomised controlled trial. The Netherlands. The obstetric departments of 24 Dutch hospitals. The obstetric departments were randomly assigned to a 1-day session of multiprofessional team training in a medical simulation centre or to no such training. Team training was given with high-fidelity mannequins by an obstetrician and a communication expert. More than 6 months following training, two unannounced simulated scenarios were carried out in the delivery rooms of all 24 obstetric departments. The scenarios, comprising a case of shoulder dystocia and a case of amniotic fluid embolism, were videotaped. The team performance and utilisation of appropriate medical skills were evaluated by two independent experts. Team performance evaluated with the validated Clinical Teamwork Scale (CTS) and the employment of two specific obstetric procedures for the two clinical scenarios in the simulation (delivery of the baby with shoulder dystocia in the maternal all-fours position and conducting a perimortem caesarean section within 5 minutes for the scenario of amniotic fluid embolism). Seventy-four obstetric teams from 12 hospitals in the intervention group underwent teamwork training between November 2009 and July 2010. The teamwork performance in the training group was significantly better in comparison to the nontraining group (median CTS score: 7.5 versus 6.0, respectively; P = 0.014). The use of the predefined obstetric procedures for the two clinical scenarios was also significantly more frequent in the training group compared with the nontraining group (83 versus 46%, respectively; P = 0.009). Team performance and medical technical skills may be significantly improved after multiprofessional obstetric team training in a medical simulation centre. © 2012 The Authors BJOG An International Journal of Obstetrics and Gynaecology © 2012 RCOG.

  5. Application of Support Vector Machine to Forex Monitoring

    NASA Astrophysics Data System (ADS)

    Kamruzzaman, Joarder; Sarker, Ruhul A.

    Previous studies have demonstrated superior performance of artificial neural network (ANN) based forex forecasting models over traditional regression models. This paper applies support vector machines to build a forecasting model from the historical data using six simple technical indicators and presents a comparison with an ANN based model trained by scaled conjugate gradient (SCG) learning algorithm. The models are evaluated and compared on the basis of five commonly used performance metrics that measure closeness of prediction as well as correctness in directional change. Forecasting results of six different currencies against Australian dollar reveal superior performance of SVM model using simple linear kernel over ANN-SCG model in terms of all the evaluation metrics. The effect of SVM parameter selection on prediction performance is also investigated and analyzed.

  6. 77 FR 27814 - Model Safety Evaluation for Plant-Specific Adoption of Technical Specifications Task Force...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-11

    ... NUCLEAR REGULATORY COMMISSION [Project No. 753; NRC-2012-0019] Model Safety Evaluation for Plant... Regulatory Commission (NRC) is announcing the availability of the model safety evaluation (SE) for plant... the Improved Standard Technical Specification (ISTS), NUREG-1431, ``Standard Technical Specifications...

  7. 76 FR 9607 - Notice of Proposed Information Collection for Technical Evaluation Surveys

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-18

    ... Information Collection for Technical Evaluation Surveys AGENCY: Office of Surface Mining Reclamation and... information collection request for its Technical Evaluation customer surveys has been forwarded to the Office of Management and Budget (OMB) for review and comment. The information collection request describes...

  8. An Input Evaluation of Three Technical Assistance Needs Assessment Strategies.

    ERIC Educational Resources Information Center

    Suarez, Tanya M.; Cox, James O.

    The Technical Assistance Development System--TADS (a project to provide technical assistance to personnel implementing programs for preschool handicapped children and their families) conducted an evaluation of three technical assistance needs assessment strategies during 1979-80. The three strategies were: (1) on-site--conducted by a trained needs…

  9. Development of an instrument for the evaluation of advanced life support performance.

    PubMed

    Peltonen, L-M; Peltonen, V; Salanterä, S; Tommila, M

    2017-10-01

    Assessing advanced life support (ALS) competence requires validated instruments. Existing instruments include aspects of technical skills (TS), non-technical skills (NTS) or both, but one instrument for detailed assessment that suits all resuscitation situations is lacking. This study aimed to develop an instrument for the evaluation of the overall ALS performance of the whole team. This instrument development study had four phases. First, we reviewed literature and resuscitation guidelines to explore items to include in the instrument. Thereafter, we interviewed resuscitation team professionals (n = 66), using the critical incident technique, to determine possible additional aspects associated with the performance of ALS. Second, we developed an instrument based on the findings. Third, we used an expert panel (n = 20) to assess the validity of the developed instrument. Finally, we revised the instrument based on the experts' comments and tested it with six experts who evaluated 22 video recorded resuscitations. The final version of the developed instrument had 69 items divided into adherence to guidelines (28 items), clinical decision-making (5 items), workload management (12 items), team behaviour (8 items), information management (6 items), patient integrity and consideration of laymen (4 items) and work routines (6 items). The Cronbach's α values were good, and strong correlations between the overall performance and the instrument were observed. The instrument may be useful for detailed assessment of the team's overall performance, but the numerous items make the use demanding. The instrument is still under development, and more research is needed to determine its psychometric properties. © 2017 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  10. The Anatomy of AP1000 Mono-Block Low Pressure Rotor Forging

    NASA Astrophysics Data System (ADS)

    Jin, Jia-yu; Rui, Shou-tai; Wang, Qun

    AP1000 mono-block low pressure (LP) rotor forgings for nuclear power station have maximum ingot weight, maximum diameter and the highest technical requirements. It confronts many technical problems during manufacturing process such as composition segregation and control of inclusion in the large ingot, core compaction during forging, control of grain size and mechanical performance. The rotor forging were anatomized to evaluate the manufacturing level of CFHI. This article introduces the anatomical results of this forging. The contents include chemical composition, mechanical properties, inclusions and grain size and other aspects from the full-length and full cross-section of this forging. The fluctuation of mechanical properties, uniformity of microstructure and purity of chemical composition were emphasized. The results show that the overall performance of this rotor forging is particularly satisfying.

  11. JV Task 120 - Coal Ash Resources Research Consortium Research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Debra Pflughoeft-Hassett; Loreal Heebink; David Hassett

    2009-03-28

    The Coal Ash Resources Research Consortium{reg_sign} (CARRC{reg_sign}, pronounced 'cars') is the core coal combustion product (CCP) research group at the Energy & Environmental Research Center (EERC). CARRC focuses on performing fundamental and applied scientific and engineering research emphasizing the environmentally safe, economical use of CCPs. CARRC member organizations, which include utilities and marketers, are key to developing industry-driven research in the area of CCP utilization and ensuring its successful application. The U.S. Department of Energy is a partner in CARRC through the EERC Jointly Sponsored Research Program, which provides matching funds for industrial member contributions and facilitates an increased levelmore » of effort in CARRC. CARRC tasks were designed to provide information on CCP performance, including environmental performance, engineering performance, favorable economics, and improved life cycle of products and projects. CARRC technical research tasks are developed based on member input and prioritization. CARRC special projects are developed with members and nonmembers to provide similar information and to support activities, including the assembly and interpretation of data, support for standards development and technology transfer, and facilitating product development and testing. CARRC activities from 2007 to 2009 included a range of research tasks, with primary work performed in laboratory tasks developed to answer specific questions or evaluate important fundamental properties of CCPs. The tasks were included in four categories: (1) Environmental Evaluations of CCPs; (2) Evaluation of Impacts on CCPs from Emission Controls; (3) Construction and Product-Related Activities; and (4) Technology Transfer and Maintenance Tasks. All tasks are designed to work toward achieving the CARRC overall goal and supporting objectives. The various tasks are coordinated in order to provide broad and useful technical data for CARRC members. Special projects provide an opportunity for non-CARRC members to sponsor specific research or technology transfer consistent with CARRC goals. This report covers CARRC activities from January 2007 through March 2009. These activities have been reported in CARRC Annual Reports and in member meetings over the past 2 years. CARRC continues to work with industry and various government agencies with its research, development, demonstration, and promotional activities nearing completion at the time of submission of this report. CARRC expects to continue its service to the coal ash industry in 2009 and beyond to work toward the common goal of advancing coal ash utilization by solving CCP-related technical issues and promoting the environmentally safe, technically sound, and economically viable management of these complex and changing materials.« less

  12. Building America Industrialized Housing Partnership (BAIHP II)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abernethy, Bob; Chandra, Subrato; Baden, Steven

    2010-11-30

    This report summarizes the work conducted by the Building America Industrialized Housing Partnership (BAIHP - www.baihp.org) during the final budget period (BP5) of our contract, January 1, 2010 to November 30, 2010. Highlights from the four previous budget periods are included for context. BAIHP is led by the Florida Solar Energy Center (FSEC) of the University of Central Florida. With over 50 Industry Partners including factory and site builders, work in BP5 was performed in six tasks areas: Building America System Research Management, Documentation and Technical Support; System Performance Evaluations; Prototype House Evaluations; Initial Community Scale Evaluations; Project Closeout, Finalmore » Review of BA Communities; and Other Research Activities.« less

  13. PKI solar thermal plant evaluation at Capitol Concrete Products, Topeka, Kansas

    NASA Astrophysics Data System (ADS)

    Hauger, J. S.; Borton, D. N.

    1982-07-01

    A system feasibility test to determine the technical and operational feasibility of using a solar collector to provide industrial process heat is discussed. The test is of a solar collector system in an industrial test bed plant at Capitol Concrete Products in Topeka, Kansas, with an experiment control at Sandia National Laboratories, Albuquerque. Plant evaluation will occur during a year-long period of industrial utilization. It will include performance testing, operability testing, and system failure analysis. Performance data will be recorded by a data acquisition system. User, community, and environmental inputs will be recorded in logs, journals, and files. Plant installation, start-up, and evaluation, are anticipated for late November, 1981.

  14. PKI solar thermal plant evaluation at Capitol Concrete Products, Topeka, Kansas

    NASA Technical Reports Server (NTRS)

    Hauger, J. S.; Borton, D. N.

    1982-01-01

    A system feasibility test to determine the technical and operational feasibility of using a solar collector to provide industrial process heat is discussed. The test is of a solar collector system in an industrial test bed plant at Capitol Concrete Products in Topeka, Kansas, with an experiment control at Sandia National Laboratories, Albuquerque. Plant evaluation will occur during a year-long period of industrial utilization. It will include performance testing, operability testing, and system failure analysis. Performance data will be recorded by a data acquisition system. User, community, and environmental inputs will be recorded in logs, journals, and files. Plant installation, start-up, and evaluation, are anticipated for late November, 1981.

  15. Development of superior asphalt recycling agents. Phase 1, Technical feasibility. Final technical progress report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bullin, J.A.; Davison, R.R.; Glover, C.J.

    1997-07-01

    After an introduction and a literature survey in Chap. 1, Chap. 2 describes the tasks, together with objectives and important results obtained for each task throughout the entire project. Chaps. 3 thru 7 detail work in developing a qualitative and quantitative knowledge of asphalt oxidation, composition dependence of asphalt properties, and guidelines for producing superior asphalt binders through composition control. They also detail the development of a kinetic model for asphalt oxidative aging and present an understanding of the composition dependence of asphalt oxidation as well as other performance-related properties. Chaps. 8 and 9 compare the aging performance of recycledmore » blends produced using commercial recycling agents and industrial supercritical fractions as rejuvenating agents. Oxidative aging of the recycled blends were evaluated along with the performance of the recycled blends in terms of the strategic highway research program performance grading procedure. Chap. 10 summarizes the work completed in the areas of processing schemes development, projection updates, and scale-up and commercialization plans.« less

  16. [Acoustic conditions in open plan office - Application of technical measures in a typical room].

    PubMed

    Mikulski, Witold

    2018-03-09

    Noise in open plan offices should not exceed acceptable levels for the hearing protection. Its major negative effects on employees are nuisance and impediment in execution of work. Specific technical solutions should be introduced to provide proper acoustic conditions for work performance. Acoustic evaluation of a typical open plan office was presented in the article published in "Medycyna Pracy" 5/2016. None of the rooms meets all the criteria, therefore, in this article one of the rooms was chosen to apply different technical solutions to check the possibility of reaching proper acoustic conditions. Acoustic effectiveness of those solutions was verified by means of digital simulation. The model was checked by comparing the results of measurements and calculations before using simulation. The analyzis revealed that open plan offices supplemented with signals for masking speech signals can meet all the required criteria. It is relatively easy to reach proper reverberation time (i.e., sound absorption). It is more difficult to reach proper values of evaluation parameters determined from A-weighted sound pressure level (SPLA) of speech. The most difficult is to provide proper values of evaluation parameters determined from speech transmission index (STI). Finally, it is necessary (besides acoustic treatment) to use devices for speech masking. The study proved that it is technically possible to reach proper acoustic condition. Main causes of employees complaints in open plan office are inadequate acoustic work conditions. Therefore, it is necessary to apply specific technical solutions - not only sound absorbing suspended ceiling and high acoustic barriers, but also devices for speech masking. Med Pr 2018;69(2):153-165. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  17. A Comparative Study of Students’ Track and Field Technical Performance in Sport Education and in a Direct Instruction Approach

    PubMed Central

    Pereira, José; Hastie, Peter; Araújo, Rui; Farias, Cláudio; Rolim, Ramiro; Mesquita, Isabel

    2015-01-01

    This study examined students’ technical performances improvements in three track and field events (hurdles, shot put, and long jump) following either a Sport Education season or a Direct Instruction unit. An experienced Physical Education teacher taught two classes totalling 47 sixth-grade students (25 boys and 22 girls, aged between 10 and 13 years old) in 20, 45-minute lessons over 10 weeks. The students’ technical performances were analysed and evaluated through systematic observation of videos. The Wilcoxon signed-rank test was used to compare scores at three time points (pre-test, post-test and retention), and the Mann-Whitney U test was used to examine the differences within each instructional model at each assessment moment, as well as by gender and skill level. The impact of each instructional model in student learning was markedly distinct. While in Sport Education students of both genders and skill levels improved significantly in all events, in Direct Instruction, evidence of significant improvements was limited to boys and students of higher skill level. Key points The impact of each teaching approach in student learning was distinct. While in Sport Education the technical performance improvements spread throughout students of both genders and skill levels, in Direct Instruction significant improvements were exclusive to boys and students of higher skill level. The extended analysis in the current study, taking into account student gender and skill level, permitted a more comprehensive measure of the learning impact of the two approaches. More sophisticated analyses of the tasks and instructional strategies of each approach are encouraged. PMID:25729299

  18. High Performance Flat Plate Solar Thermal Collector Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rockenbaugh, Caleb; Dean, Jesse; Lovullo, David

    2016-09-01

    This report was prepared for the General Services Administration by the National Renewable Energy Laboratory. The Honeycomb Solar Thermal Collector (HSTC) is a flat plate solar thermal collector that shows promising high efficiencies over a wide range of climate zones. The technical objectives of this study are to: 1) verify collector performance, 2) compare that performance to other market-available collectors, 3) verify overheat protection, and 4) analyze the economic performance of the HSTC both at the demonstration sites and across a matrix of climate zones and utility markets.

  19. Semiautomated external defibrillators for in-hospital early defibrillation: a comparative study.

    PubMed

    Nocchi, Federico; Derrico, Pietro; Masucci, Gerardina; Capussotto, Carlo; Cecchetti, Corrado; Ritrovato, Matteo

    2014-01-01

    Semiautomated external defibrillators (AEDs) should be considered as a means to facilitate in-hospital early defibrillation (IHED) in areas where advanced life support rescuers are not readily available. In this study, we aimed to develop a checklist and a measurement protocol to evaluate and compare AEDs by assessing factors that may affect IHED. A clinical and technical comparison of six AEDs was performed. Technical specifications were analyzed, while an emergency team evaluated ergonomics and appropriateness for IHED at Bambino Gesù Children's Hospital. A measurement protocol was implemented, which aimed to assess the ability of defibrillators to recognize shockable and nonshockable rhythms, accuracy of delivered energy, and charging time. Designs of AEDs differed in several features which influence their appropriateness for IHED. Some units showed poor ergonomics and instructions/feedback for cardiopulmonary resuscitation. Differences between defibrillators in recognizing shockable and nonshockable rhythms emerged for polymorphic ventricular tachycardia waveforms and when the frequency and amplitude of input signals varied. Tests for accuracy revealed poor performances at low and high impedance levels for most AEDs. Notably, differences greater than 20 seconds were found in the time from power-on to "ready for discharge." The approach we used to assess AEDs allowed us to evaluate their appropriateness with respect to the organizational context, to measure their parameters, and to compare models. Results showed that ergonomics and/or performances (timing and accuracy) could be improved in each device.

  20. Mark 4A project training evaluation

    NASA Technical Reports Server (NTRS)

    Stephenson, S. N.

    1985-01-01

    A participant evaluation of a Deep Space Network (DSN) is described. The Mark IVA project is an implementation to upgrade the tracking and data acquisition systems of the dSN. Approximately six hundred DSN operations and engineering maintenance personnel were surveyed. The survey obtained a convenience sample including trained people within the population in order to learn what training had taken place and to what effect. The survey questionnaire used modifications of standard rating scales to evaluate over one hundred items in four training dimensions. The scope of the evaluation included Mark IVA vendor training, a systems familiarization training seminar, engineering training classes, a on-the-job training. Measures of central tendency were made from participant rating responses. Chi square tests of statistical significance were performed on the data. The evaluation results indicated that the effects of different Mark INA training methods could be measured according to certain ratings of technical training effectiveness, and that the Mark IVA technical training has exhibited positive effects on the abilities of DSN personnel to operate and maintain new Mark IVA equipment systems.

  1. Performance Evaluation of Engineered Structured Sorbents for Atmosphere Revitalization Systems On Board Crewed Space Vehicles and Habitats

    NASA Technical Reports Server (NTRS)

    Howard, David F.; Perry, Jay L.; Knox, James C.; Junaedi, Christian; Roychoudhury, Subir

    2011-01-01

    Engineered structured (ES) sorbents are being developed to meet the technical challenges of future crewed space exploration missions. ES sorbents offer the inherent performance and safety attributes of zeolite and other physical adsorbents but with greater structural integrity and process control to improve durability and efficiency over packed beds. ES sorbent techniques that are explored include thermally linked and pressure-swing adsorption beds for water-save dehumidification and sorbent-coated metal meshes for residual drying, trace contaminant control, and carbon dioxide control. Results from sub-scale performance evaluations of a thermally linked pressure-swing adsorbent bed and an integrated sub-scale ES sorbent system are discussed.

  2. A method for building evaluation competency among community-based organizations.

    PubMed

    Kelly, Cheryl M; LaRose, Jessi; Scharff, Darcell P

    2014-05-01

    Community-based organizations often lack the capacity (e.g., time, staff, skills) to effectively evaluate programs, policies, and environmental changes. Providing evaluation technical assistance and training can be an effective and feasible way to build individual evaluation competency. The purpose of this article is to present a practical approach and related tools that can be used by evaluators and others (e.g., academic partners, funders) providing assistance to build evaluation skills in community organizations. The approach described was developed in collaboration with local universities and a regional health foundation to provide intensive technical support to 19 community-based organizations awarded funding to implement obesity prevention projects. Technical assistance processes and tools were designed to be tailored to organizations' capacity and needs and can be used as templates by others who provide technical assistance. Evaluators, funders, and academic partners can use lessons learned from this experience to help shape and implement evaluation technical assistance approaches with community-based organizations.

  3. Technical indicators of economic performance in dairy sheep farming.

    PubMed

    Theodoridis, A; Ragkos, A; Roustemis, D; Arsenos, G; Abas, Z; Sinapis, E

    2014-01-01

    In this study, the level of technical efficiency of 58 sheep farms rearing the Chios breed in Greece was measured through the application of the stochastic frontier analysis method. A Translog stochastic frontier production function was estimated using farm accounting data of Chios sheep farms and the impact of various socio-demographic and biophysical factors on the estimated efficiency of the farms was evaluated. The farms were classified into efficiency groups on the basis of the estimated level of efficiency and a technical and economic descriptive analysis was applied in order to illustrate an indicative picture of their structure and productivity. The results of the stochastic frontier model indicate that there are substantial production inefficiencies among the Chios sheep farms and that these farms could increase their production through the improvement of technical efficiency, whereas the results of the inefficiency effects model reveal that the farm-specific explanatory factors can partly explain the observed efficiency differentials. The measurement of technical inefficiency and the detection of its determinants can be used to form the basis of policy recommendations that could contribute to the development of the sector.

  4. Technical Packages in Injury and Violence Prevention to Move Evidence Into Practice: Systematic Reviews and Beyond.

    PubMed

    Haegerich, Tamara M; David-Ferdon, Corinne; Noonan, Rita K; Manns, Brian J; Billie, Holly C

    2016-09-07

    Injury and violence prevention strategies have greater potential for impact when they are based on scientific evidence. Systematic reviews of the scientific evidence can contribute key information about which policies and programs might have the greatest impact when implemented. However, systematic reviews have limitations, such as lack of implementation guidance and contextual information, that can limit the application of knowledge. "Technical packages," developed by knowledge brokers such as the federal government, nonprofit agencies, and academic institutions, have the potential to be an efficient mechanism for making information from systematic reviews actionable. Technical packages provide information about specific evidence-based prevention strategies, along with the estimated costs and impacts, and include accompanying implementation and evaluation guidance to facilitate adoption, implementation, and performance measurement. We describe how systematic reviews can inform the development of technical packages for practitioners, provide examples of technical packages in injury and violence prevention, and explain how enhancing review methods and reporting could facilitate the use and applicability of scientific evidence. © The Author(s) 2016.

  5. 1983-84 Evaluation Report of Vocational and Technical Education in South Carolina.

    ERIC Educational Resources Information Center

    South Carolina State Advisory Council on Vocational and Technical Education, Columbia.

    This evaluation report contains a series of articles on vocational and technical education encompassing the 1983-84 school year. The articles, collectively, are intended to give an overall picture of vocational and technical education programs in South Carolina. The lead article on technical education strongly urges several changes to bring about…

  6. A comparative analysis of user preference-based and existing knowledge management systems attributes in the aerospace industry

    NASA Astrophysics Data System (ADS)

    Varghese, Nishad G.

    Knowledge management (KM) exists in various forms throughout organizations. Process documentation, training courses, and experience sharing are examples of KM activities performed daily. The goal of KM systems (KMS) is to provide a tool set which serves to standardize the creation, sharing, and acquisition of business critical information. Existing literature provides numerous examples of targeted evaluations of KMS, focusing on specific system attributes. This research serves to bridge the targeted evaluations with an industry-specific, holistic approach. The user preferences of aerospace employees in engineering and engineering-related fields were compared to profiles of existing aerospace KMS based on three attribute categories: technical features, system administration, and user experience. The results indicated there is a statistically significant difference between aerospace user preferences and existing profiles in the user experience attribute category, but no statistically significant difference in the technical features and system administration attribute categories. Additional analysis indicated in-house developed systems exhibit higher technical features and user experience ratings than commercial-off-the-self (COTS) systems.

  7. Validity evidence for the Simulated Colonoscopy Objective Performance Evaluation scoring system.

    PubMed

    Trinca, Kristen D; Cox, Tiffany C; Pearl, Jonathan P; Ritter, E Matthew

    2014-02-01

    Low-cost, objective systems to assess and train endoscopy skills are needed. The aim of this study was to evaluate the ability of Simulated Colonoscopy Objective Performance Evaluation to assess the skills required to perform endoscopy. Thirty-eight subjects were included in this study, all of whom performed 4 tasks. The scoring system measured performance by calculating precision and efficiency. Data analysis assessed the relationship between colonoscopy experience and performance on each task and the overall score. Endoscopic trainees' Simulated Colonoscopy Objective Performance Evaluation scores correlated significantly with total colonoscopy experience (r = .61, P = .003) and experience in the past 12 months (r = .63, P = .002). Significant differences were seen among practicing endoscopists, nonendoscopic surgeons, and trainees (P < .0001). When the 4 tasks were analyzed, each showed significant correlation with colonoscopy experience (scope manipulation, r = .44, P = .044; tool targeting, r = .45, P = .04; loop management, r = .47, P = .032; mucosal inspection, r = .65, P = .001) and significant differences in performance between the endoscopist groups, except for mucosal inspection (scope manipulation, P < .0001; tool targeting, P = .002; loop management, P = .0008; mucosal inspection, P = .27). Simulated Colonoscopy Objective Performance Evaluation objectively assesses the technical skills required to perform endoscopy and shows promise as a platform for proficiency-based skills training. Published by Elsevier Inc.

  8. Technical Aspects of Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration: CHEST Guideline and Expert Panel Report.

    PubMed

    Wahidi, Momen M; Herth, Felix; Yasufuku, Kazuhiro; Shepherd, Ray Wesley; Yarmus, Lonny; Chawla, Mohit; Lamb, Carla; Casey, Kenneth R; Patel, Sheena; Silvestri, Gerard A; Feller-Kopman, David J

    2016-03-01

    Endobronchial ultrasound (EBUS) was introduced in the last decade, enabling real-time guidance of transbronchial needle aspiration (TBNA) of mediastinal and hilar structures and parabronchial lung masses. The many publications produced about EBUS-TBNA have led to a better understanding of the performance characteristics of this procedure. The goal of this document was to examine the current literature on the technical aspects of EBUS-TBNA as they relate to patient, technology, and proceduralist factors to provide evidence-based and expert guidance to clinicians. Rigorous methodology has been applied to provide a trustworthy evidence-based guideline and expert panel report. A group of approved panelists developed key clinical questions by using the PICO (population, intervention, comparator, and outcome) format that addressed specific topics on the technical aspects of EBUS-TBNA. MEDLINE (via PubMed) and the Cochrane Library were systematically searched for relevant literature, which was supplemented by manual searches. References were screened for inclusion, and well-recognized document evaluation tools were used to assess the quality of included studies, to extract meaningful data, and to grade the level of evidence to support each recommendation or suggestion. Our systematic review and critical analysis of the literature on 15 PICO questions related to the technical aspects of EBUS-TBNA resulted in 12 statements: 7 evidence-based graded recommendations and 5 ungraded consensus-based statements. Three questions did not have sufficient evidence to generate a statement. Evidence on the technical aspects of EBUS-TBNA varies in strength but is satisfactory in certain areas to guide clinicians on the best conditions to perform EBUS-guided tissue sampling. Additional research is needed to enhance our knowledge regarding the optimal performance of this effective procedure. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  9. Introducing a Fresh Cadaver Model for Ultrasound-guided Central Venous Access Training in Undergraduate Medical Education

    PubMed Central

    Miller, Ryan; Ho, Hang; Ng, Vivienne; Tran, Melissa; Rappaport, Douglas; Rappaport, William J.A.; Dandorf, Stewart J.; Dunleavy, James; Viscusi, Rebecca; Amini, Richard

    2016-01-01

    Introduction Over the past decade, medical students have witnessed a decline in the opportunities to perform technical skills during their clinical years. Ultrasound-guided central venous access (USG-CVA) is a critical procedure commonly performed by emergency medicine, anesthesia, and general surgery residents, often during their first month of residency. However, the acquisition of skills required to safely perform this procedure is often deficient upon graduation from medical school. To ameliorate this lack of technical proficiency, ultrasound simulation models have been introduced into undergraduate medical education to train venous access skills. Criticisms of simulation models are the innate lack of realistic tactile qualities, as well as the lack of anatomical variances when compared to living patients. The purpose of our investigation was to design and evaluate a life-like and reproducible training model for USG-CVA using a fresh cadaver. Methods This was a cross-sectional study at an urban academic medical center. An 18-point procedural knowledge tool and an 18-point procedural skill evaluation tool were administered during a cadaver lab at the beginning and end of the surgical clerkship. During the fresh cadaver lab, procedure naïve third-year medical students were trained on how to perform ultrasound-guided central venous access of the femoral and internal jugular vessels. Preparation of the fresh cadaver model involved placement of a thin-walled latex tubing in the anatomic location of the femoral and internal jugular vein respectively. Results Fifty-six third-year medical students participated in this study during their surgical clerkship. The fresh cadaver model provided high quality and lifelike ultrasound images despite numerous cannulation attempts. Technical skill scores improved from an average score of 3 to 12 (p<0.001) and procedural knowledge scores improved from an average score of 4 to 8 (p<0.001). Conclusion The use of this novel cadaver model prevented extravasation of fluid, maintained ultrasound-imaging quality, and proved to be an effective educational model allowing third-year medical students to improve and maintain their technical skills. PMID:27330672

  10. Introducing a Fresh Cadaver Model for Ultrasound-guided Central Venous Access Training in Undergraduate Medical Education.

    PubMed

    Miller, Ryan; Ho, Hang; Ng, Vivienne; Tran, Melissa; Rappaport, Douglas; Rappaport, William J A; Dandorf, Stewart J; Dunleavy, James; Viscusi, Rebecca; Amini, Richard

    2016-05-01

    Over the past decade, medical students have witnessed a decline in the opportunities to perform technical skills during their clinical years. Ultrasound-guided central venous access (USG-CVA) is a critical procedure commonly performed by emergency medicine, anesthesia, and general surgery residents, often during their first month of residency. However, the acquisition of skills required to safely perform this procedure is often deficient upon graduation from medical school. To ameliorate this lack of technical proficiency, ultrasound simulation models have been introduced into undergraduate medical education to train venous access skills. Criticisms of simulation models are the innate lack of realistic tactile qualities, as well as the lack of anatomical variances when compared to living patients. The purpose of our investigation was to design and evaluate a life-like and reproducible training model for USG-CVA using a fresh cadaver. This was a cross-sectional study at an urban academic medical center. An 18-point procedural knowledge tool and an 18-point procedural skill evaluation tool were administered during a cadaver lab at the beginning and end of the surgical clerkship. During the fresh cadaver lab, procedure naïve third-year medical students were trained on how to perform ultrasound-guided central venous access of the femoral and internal jugular vessels. Preparation of the fresh cadaver model involved placement of a thin-walled latex tubing in the anatomic location of the femoral and internal jugular vein respectively. Fifty-six third-year medical students participated in this study during their surgical clerkship. The fresh cadaver model provided high quality and lifelike ultrasound images despite numerous cannulation attempts. Technical skill scores improved from an average score of 3 to 12 (p<0.001) and procedural knowledge scores improved from an average score of 4 to 8 (p<0.001). The use of this novel cadaver model prevented extravasation of fluid, maintained ultrasound-imaging quality, and proved to be an effective educational model allowing third-year medical students to improve and maintain their technical skills.

  11. Electrification Futures Study: A Technical Evaluation of the Impacts of an

    Science.gov Websites

    Technical Evaluation of the Impacts of an Electrified U.S. Energy System Electrification Futures Study: A Technical Evaluation of the Impacts of an Electrified U.S. Energy System Illustration showing various impacts of widespread electrification in the United States. In addition to NREL, the research team

  12. [Discussion on Technical Evaluation for Medical Device Registration Material].

    PubMed

    Chu, Yungao; Qian, Hong; Zhu, Yingfeng

    2017-07-30

    This article first introduces the main contents of the requirements for medical device registration. Secondly, this article chooses the vertebral forming surgery system as an example to discuss the technical evaluation for the registration research material. The article hopes to provide a reference for the applicant who prepare the registration material and the technical evaluator who make the evaluation for the medical device registration.

  13. Evaluation of Factors Unique to Multifunction Controls/Displays Devices

    DTIC Science & Technology

    1980-11-01

    different Iron Report) 18. SUPPLEMENTARY NOTES This work was performed by the contractor at the Flight Dynamics Laboratory, Flight Control Division, Crew...This Technical Report is the result of a work effort performed by the Require- ments and Analysis Group of the Crew Systems Development Branch (FIGR...human factors. Mr. Emmett Herron of the Bunker Ramo Corporation provided pilot inputs to the work efforts, and Ms. Gloria Calhoun of the same company

  14. Space station data system analysis/architecture study. Task 4: System definition report

    NASA Technical Reports Server (NTRS)

    1985-01-01

    Functional/performance requirements for the Space Station Data System (SSDS) are analyzed and architectural design concepts are derived and evaluated in terms of their performance and growth potential, technical feasibility and risk, and cost effectiveness. The design concepts discussed are grouped under five major areas: SSDS top-level architecture overview, end-to-end SSDS design and operations perspective, communications assumptions and traffic analysis, onboard SSDS definition, and ground SSDS definition.

  15. Cell-NPE (Numerical Performance Evaluation): Programming the IBM Cell Broadband Engine -- A General Parallelization Strategy

    DTIC Science & Technology

    2008-04-01

    Space GmbH as follows: B. TECHNICAL PRPOPOSA/DESCRIPTION OF WORK Cell: A Revolutionary High Performance Computing Platform On 29 June 2005 [1...IBM has announced that is has partnered with Mercury Computer Systems, a maker of specialized computers . The Cell chip provides massive floating-point...the computing industry away from the traditional processor technology dominated by Intel. While in the past, the development of computing power has

  16. Comparing multi-criteria decision analysis and integrated assessment to support long-term water supply planning

    PubMed Central

    Maurer, Max; Lienert, Judit

    2017-01-01

    We compare the use of multi-criteria decision analysis (MCDA)–or more precisely, models used in multi-attribute value theory (MAVT)–to integrated assessment (IA) models for supporting long-term water supply planning in a small town case study in Switzerland. They are used to evaluate thirteen system scale water supply alternatives in four future scenarios regarding forty-four objectives, covering technical, social, environmental, and economic aspects. The alternatives encompass both conventional and unconventional solutions and differ regarding technical, spatial and organizational characteristics. This paper focuses on the impact assessment and final evaluation step of the structured MCDA decision support process. We analyze the performance of the alternatives for ten stakeholders. We demonstrate the implications of model assumptions by comparing two IA and three MAVT evaluation model layouts of different complexity. For this comparison, we focus on the validity (ranking stability), desirability (value), and distinguishability (value range) of the alternatives given the five model layouts. These layouts exclude or include stakeholder preferences and uncertainties. Even though all five led us to identify the same best alternatives, they did not produce identical rankings. We found that the MAVT-type models provide higher distinguishability and a more robust basis for discussion than the IA-type models. The needed complexity of the model, however, should be determined based on the intended use of the model within the decision support process. The best-performing alternatives had consistently strong performance for all stakeholders and future scenarios, whereas the current water supply system was outperformed in all evaluation layouts. The best-performing alternatives comprise proactive pipe rehabilitation, adapted firefighting provisions, and decentralized water storage and/or treatment. We present recommendations for possible ways of improving water supply planning in the case study and beyond. PMID:28481881

  17. Evaluation of Angiographic and Technical Aspects of Carotid Stenting with Diffusion-Weighted Magnetic Resonance Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blasel, Stella, E-mail: Stella.Blasel@kgu.de; Hattingen, Elke; Berkefeld, Joachim

    2009-07-15

    The detection of clinically silent ischemic lesions on postprocedural diffusion-weighted magnetic resonance images has become a preferred method for the description of embolic risks. The purpose of this single-center study was to evaluate whether diffusion-weighted imaging (DWI) could determine material related or technical risk factors of filter-protected carotid stenting. Eighty-four patients with symptomatic severe ({>=}60%) carotid artery stenoses received filter-protected carotid stenting. Standard DWI (b = 1000) was performed within 48 h before and after carotid stenting. The occurrence and load of new postinterventional DWI lesions were assessed. Multivariate analysis was performed to determine risk factors associated with DWI lesions,more » with emphasis on technical factors such as use of different access devices (guiding catheter method vs. long carotid sheath method), type of stent (open-cell nitinol stent vs. closed-cell Wallstent), and protective device (filters with 80-{mu}m vs. 110-120-{mu}m pore size). Markers for generalized atherosclerosis and for degree and site of stenosis were assessed to allow comparison of adequate risk profiles. Access, protective device, and stent type were not significantly associated with new embolic DWI lesions when we compared patients with equivalent risk profiles (long carotid sheath method 48% [11 of 23] vs. guiding catheter method 44% [27 of 61], Wallstent 47% [15 of 32] vs. nitinol stent 44% [23 of 52], and small pore size filter 61% [11 of 18] vs. large pore size filter 41% [27 of 66]). Single-center DWI studies with a moderate number of cases are inadequate for proper assessment of the embolic risk of technical- or material-related risk factors in carotid stenting. Larger multicenter studies with more cases are needed.« less

  18. Surgeons' and trainees' perceived self-efficacy in operating theatre non-technical skills.

    PubMed

    Pena, G; Altree, M; Field, J; Thomas, M J W; Hewett, P; Babidge, W; Maddern, G J

    2015-05-01

    An important factor that may influence an individual's performance is self-efficacy, a personal judgement of capability to perform a particular task successfully. This prospective study explored newly qualified surgeons' and surgical trainees' self-efficacy in non-technical skills compared with their non-technical skills performance in simulated scenarios. Participants undertook surgical scenarios challenging non-technical skills in two simulation sessions 6 weeks apart. Some participants attended a non-technical skills workshop between sessions. Participants completed pretraining and post-training surveys about their perceived self-efficacy in non-technical skills, which were analysed and compared with their performance in surgical scenarios in two simulation sessions. Change in performance between sessions was compared with any change in participants' perceived self-efficacy. There were 40 participants in all, 17 of whom attended the non-technical skills workshop. There was no significant difference in participants' self-efficacy regarding non-technical skills from the pretraining to the post-training survey. However, there was a tendency for participants with the highest reported self-efficacy to adjust their score downwards after training and for participants with the lowest self-efficacy to adjust their score upwards. Although there was significant improvement in non-technical skills performance from the first to second simulation sessions, a correlation between participants' self-efficacy and performance in scenarios in any of the comparisons was not found. The results suggest that new surgeons and surgical trainees have poor insight into their non-technical skills. Although it was not possible to correlate participants' self-belief in their abilities directly with their performance in a simulation, in general they became more critical in appraisal of their abilities as a result of the intervention. © 2015 BJS Society Ltd Published by John Wiley & Sons Ltd.

  19. Administration and Research of Competency-/Performance-Based Teacher Education Programs.

    ERIC Educational Resources Information Center

    Trzasko, Joseph A.

    This paper describes the proposed Assessment Center at Mercy College in Dobbs Ferry, New York. The center is intended to provide statistical and technical support for the Mercy College elementary education, special education, and speech and hearing departments in the areas of student assessment, student guidance, and program evaluation. Evaluation…

  20. Comparing Two CBM Maze Selection Tools: Considering Scoring and Interpretive Metrics for Universal Screening

    ERIC Educational Resources Information Center

    Ford, Jeremy W.; Missall, Kristen N.; Hosp, John L.; Kuhle, Jennifer L.

    2016-01-01

    Advances in maze selection curriculum-based measurement have led to several published tools with technical information for interpretation (e.g., norms, benchmarks, cut-scores, classification accuracy) that have increased their usefulness for universal screening. A range of scoring practices have emerged for evaluating student performance on maze…

  1. 43 CFR 404.23 - How will Reclamation determine whether you or your contractor is qualified to conduct an...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... or your contractor is qualified to conduct an appraisal investigation or a feasibility study? 404.23... feasibility study yourself or though a contractor, Reclamation will evaluate whether you, your technical staff, or contractor are qualified to perform the appraisal investigation or feasibility study based on...

  2. Replicating Experimental Impact Estimates Using a Regression Discontinuity Approach. NCEE 2012-4025

    ERIC Educational Resources Information Center

    Gleason, Philip M.; Resch, Alexandra M.; Berk, Jillian A.

    2012-01-01

    This NCEE Technical Methods Paper compares the estimated impacts of an educational intervention using experimental and regression discontinuity (RD) study designs. The analysis used data from two large-scale randomized controlled trials--the Education Technology Evaluation and the Teach for America Study--to provide evidence on the performance of…

  3. Tyche 3.0 Simulation Engine Project Review

    DTIC Science & Technology

    2014-10-09

    la Reine (en droit du Canada), telle que représentée par le ministre de la Défense nationale, 2014 DRDC-RDDC-2014-C220 Page 2 RECORD OF...During the technical evaluation, it was found that the representation of internal data as class objects and collections had performance drawbacks and

  4. The Colorado experience (evaluation and selection of hardware for automated, geo-based information systems)

    NASA Technical Reports Server (NTRS)

    Sonnenl, D.

    1981-01-01

    A turnkey system which gives technical assistance to legislative redistricting and state census data affiliate activities is described. The procedures followed for the acquisition of the Colorado automated census mapping system are presented. Price and performance criteria of the system were examined and the system architecture is outlined.

  5. A Bayesian Method for Evaluating Trainee Proficiency. Technical Paper 323.

    ERIC Educational Resources Information Center

    Epstein, Kenneth I.; Steinheiser, Frederick H., Jr.

    A multiparameter, programmable model was developed to examine the interactive influence of certain parameters on the probability of deciding that an examinee had attained a specified degree of mastery. It was applied within the simulated context of performance testing of military trainees. These parameters included: (1) the number of assumed…

  6. Computer-Based Simulations for Maintenance Training: Current ARI Research. Technical Report 544.

    ERIC Educational Resources Information Center

    Knerr, Bruce W.; And Others

    Three research efforts that used computer-based simulations for maintenance training were in progress when this report was written: Game-Based Learning, which investigated the use of computer-based games to train electronics diagnostic skills; Human Performance in Fault Diagnosis Tasks, which evaluated the use of context-free tasks to train…

  7. MRI-guidance in percutaneous core decompression of osteonecrosis of the femoral head.

    PubMed

    Kerimaa, Pekka; Väänänen, Matti; Ojala, Risto; Hyvönen, Pekka; Lehenkari, Petri; Tervonen, Osmo; Blanco Sequeiros, Roberto

    2016-04-01

    The purpose of this study was to evaluate the usefulness of MRI-guidance for core decompression of avascular necrosis of the femoral head. Twelve MRI-guided core decompressions were performed on patients with different stages of avascular necrosis of the femoral head. The patients were asked to evaluate their pain and their ability to function before and after the procedure and imaging findings were reviewed respectively. Technical success in reaching the target was 100 % without complications. Mean duration of the procedure itself was 54 min. All patients with ARCO stage 1 osteonecrosis experienced clinical benefit and pathological MRI findings were seen to diminish. Patients with more advanced disease gained less, if any, benefit and total hip arthroplasty was eventually performed on four patients. MRI-guidance seems technically feasible, accurate and safe for core decompression of avascular necrosis of the femoral head. Patients with early stage osteonecrosis may benefit from the procedure. • MRI is a useful guidance method for minimally invasive musculoskeletal interventions. • Bone drilling seems beneficial at early stages of avascular necrosis. • MRI-guidance is safe and accurate for bone drilling.

  8. The impact of fatigue on the non-technical skills performance of critical care air ambulance clinicians.

    PubMed

    Myers, J A; Powell, D M C; Aldington, S; Sim, D; Psirides, A; Hathaway, K; Haney, M F

    2017-11-01

    The relationship between fatigue-related risk and impaired clinical performance is not entirely clear. Non-technical factors represent an important component of clinical performance and may be sensitive to the effects of fatigue. The hypothesis was that the sum score of overall non-technical performance is degraded by fatigue. Nineteen physicians undertook two different simulated air ambulance missions, once when rested, and once when fatigued (randomised crossover design). Trained assessors blinded to participants' fatigue status performed detailed structured assessments based on expected behaviours in four non-technical skills domains: teamwork, situational awareness, task management, and decision making. Participants also provided self-ratings of their performance. The primary endpoint was the sum score of overall non-technical performance. The main finding, the overall non-technical skills performance rating of the clinicians, was better in rested than fatigued states (mean difference with 95% CI, 2.8 [2.2-3.4]). The findings remained consistent across individual non-technical skills domains; also when controlling for an order effect and examining the impact of a number of possible covariates. There was no difference in self-ratings of clinical performance between rested and fatigued states. Non-technical performance of critical care air transfer clinicians is degraded when they are fatigued. Fatigued clinicians may fail to recognise the degree to which their performance is compromised. These findings represent risk to clinical care quality and patient safety in the dynamic and isolated environment of air ambulance transfer. © 2017 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  9. An SNMP-based solution to enable remote ISO/IEEE 11073 technical management.

    PubMed

    Lasierra, Nelia; Alesanco, Alvaro; García, José

    2012-07-01

    This paper presents the design and implementation of an architecture based on the integration of simple network management protocol version 3 (SNMPv3) and the standard ISO/IEEE 11073 (X73) to manage technical information in home-based telemonitoring scenarios. This architecture includes the development of an SNMPv3-proxyX73 agent which comprises a management information base (MIB) module adapted to X73. In the proposed scenario, medical devices (MDs) send information to a concentrator device [designated as compute engine (CE)] using the X73 standard. This information together with extra information collected in the CE is stored in the developed MIB. Finally, the information collected is available for remote access via SNMP connection. Moreover, alarms and events can be configured by an external manager in order to provide warnings of irregularities in the MDs' technical performance evaluation. This proposed SNMPv3 agent provides a solution to integrate and unify technical device management in home-based telemonitoring scenarios fully adapted to X73.

  10. Technical-financial evaluation of rainwater harvesting systems in commercial buildings-case ase studies from Sonae Sierra in Portugal and Brazil.

    PubMed

    Sousa, Vitor; Silva, Cristina Matos; Meireles, Inês C

    2017-11-10

    Water is an essential and increasingly scarce resource that should be preserved. The evolution of the human population and communities has contributed to the global decrease of potable water availability and the reduction of its consumption is now compulsory. Rainwater harvesting systems (RWHS) are emerging as a viable alternative source for water consumption in non-potable uses. The present study aims to contribute to the promotion of water efficiency, focusing on the application of rainwater harvesting systems in commercial buildings, and comprises four stages: (i) development of a technical evaluation tool to aid the design of RWHS and support their financial evaluation; (ii) validation of the tool using operational data from an existing RWHS installed at Colombo Shopping Center, in Lisbon, Portugal; (iii) assessment of the sensibility of the technical evaluation tool results to the variation of the inputs, namely the precipitation and consumption, through a parametric analysis for the Colombo Shopping Center; and (iv) comparison of the performance and financial feasibility of hypothetical RWHS in two existing commercial buildings. The technical tool was applied to two Sonae Sierra's shopping centers, one in Portugal and one in Brazil. The installation of a 200-m 3 tank is advised for the first case study, allowing non-potable water savings of 60% but a payback period of about 19 years. In the Brazilian shopping, the implementation of a tank with a capacity ranging from 100 to 400 m 3 leads to non-potable savings between 20 and 50%, but with smaller payback period, under 2 years, due to the relatively lower investment costs and higher water fees.

  11. The Relationship Between Technical Errors and Decision Making Skills in the Junior Resident

    PubMed Central

    Nathwani, J. N.; Fiers, R.M.; Ray, R.D.; Witt, A.K.; Law, K. E.; DiMarco, S.M.; Pugh, C.M.

    2017-01-01

    Objective The purpose of this study is to co-evaluate resident technical errors and decision-making capabilities during placement of a subclavian central venous catheter (CVC). We hypothesize that there will be significant correlations between scenario based decision making skills, and technical proficiency in central line insertion. We also predict residents will have problems in anticipating common difficulties and generating solutions associated with line placement. Design Participants were asked to insert a subclavian central line on a simulator. After completion, residents were presented with a real life patient photograph depicting CVC placement and asked to anticipate difficulties and generate solutions. Error rates were analyzed using chi-square tests and a 5% expected error rate. Correlations were sought by comparing technical errors and scenario based decision making. Setting This study was carried out at seven tertiary care centers. Participants Study participants (N=46) consisted of largely first year research residents that could be followed longitudinally. Second year research and clinical residents were not excluded. Results Six checklist errors were committed more often than anticipated. Residents performed an average of 1.9 errors, significantly more than the 1 error, at most, per person expected (t(44)=3.82, p<.001). The most common error was performance of the procedure steps in the wrong order (28.5%, P<.001). Some of the residents (24%) had no errors, 30% committed one error, and 46 % committed more than one error. The number of technical errors committed negatively correlated with the total number of commonly identified difficulties and generated solutions (r(33)= −.429, p=.021, r(33)= −.383, p=.044 respectively). Conclusions Almost half of the surgical residents committed multiple errors while performing subclavian CVC placement. The correlation between technical errors and decision making skills suggests a critical need to train residents in both technique and error management. ACGME Competencies Medical Knowledge, Practice Based Learning and Improvement, Systems Based Practice PMID:27671618

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosenthal, A

    Southwest Technology Development Institute (SWTDI), an independent, university-based research institute, has been the operator of the Southwest Region Photovoltaic Experiment Station (SWRES) for almost 30 years. The overarching mission of SWTDI is to position PV systems and solar technologies to become cost-effective, major sources of energy for the United States. Embedded in SWTDI's general mission has been the more-focused mission of the SWRES: to provide value added technical support to the DOE Solar Energy Technologies Program (SETP) to effectively and efficiently meet the R&D needs and targets specified in the SETP Multi-Year Technical Plan. : The DOE/SETP goals of growingmore » U.S. PV manufacturing into giga-watt capacities and seeing tera-watt-hours of solar energy production in the U.S. require an infrastructure that is under development. The staff of the SWRES has supported DOE/SETP through a coherent, integrated program to address infrastructural needs inhibiting wide-scale PV deployment in three major technical categories: specialized engineering services, workforce development, and deployment facilitation. The SWRES contract underwent three major revisions during its five year period-of- performance, but all tasks and deliverables fell within the following task areas: Task 1: PV Systems Assistance Center 1. Develop a Comprehensive multi-year plan 2. Provide technical workforce development materials and workshops for PV stakeholder groups including university, professional installers, inspectors, state energy offices, Federal agencies 3. Serve on the NABCEP exam committee 4. Provide on-demand technical PV system design reviews for U.S. PV stakeholders 5. Provide PV system field testing and instrumentation, technical outreach (including extensive support for the DOE Market Transformation program) Task 2: Design-for-Manufacture PV Systems 1. Develop and install 18 kW parking carport (cost share) and PV-thermal carport (Albuquerque) deriving and publishing lessons learned Task 3: PV Codes and Standards 1. Serve as the national lead for development and preparation of all proposals (related to PV) to the National Electrical Code 2. Participate in the Standards Technical Panels for modules (UL1703) and inverters (UL1741) Task 4: Assess Inverter Long Term Reliability 1. Install and monitor identical inverters at SWRES and SERES 2. Operate and monitor all inverters for 5 years, characterizing all failures and performance trends Task 5: Test and Evaluation Support for Solar America Initiative 1. Provide test and evaluation services to the National Laboratories for stage gate and progress measurements of SAI TPP winners« less

  13. 42 CFR 493.1413 - Standard; Technical consultant responsibilities.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... consultant responsibilities. The technical consultant is responsible for the technical and scientific... of performance of instrument maintenance and function checks; (v) Assessment of test performance...

  14. 42 CFR 493.1413 - Standard; Technical consultant responsibilities.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... consultant responsibilities. The technical consultant is responsible for the technical and scientific... of performance of instrument maintenance and function checks; (v) Assessment of test performance...

  15. How can sludge dewatering devices be assessed? Development of a new DSS and its application to real case studies.

    PubMed

    Bertanza, Giorgio; Papa, Matteo; Canato, Matteo; Collivignarelli, Maria Cristina; Pedrazzani, Roberta

    2014-05-01

    A key issue in biological Waste Water Treatment Plants (WWTPs) operation is represented by the sludge management. Mechanical dewatering is a crucial stage for sludge volume reduction; though, being a costly operation, its optimization is required. We developed an original experimental methodology to evaluate the technical (dewatering efficiency) and financial (total treatment costs) performance of dewatering devices, which might be used as a DSS (Decision Support System) for WWTP managers. This tool was then applied to two real case studies for comparing, respectively, three industrial size centrifuges, and two different operation modes of the same machine (fixed installation vs. outsourcing service). In both the cases, the best option was identified, based jointly on economic and (site-specific) technical evaluations. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Patterns of technical error among surgical malpractice claims: an analysis of strategies to prevent injury to surgical patients.

    PubMed

    Regenbogen, Scott E; Greenberg, Caprice C; Studdert, David M; Lipsitz, Stuart R; Zinner, Michael J; Gawande, Atul A

    2007-11-01

    To identify the most prevalent patterns of technical errors in surgery, and evaluate commonly recommended interventions in light of these patterns. The majority of surgical adverse events involve technical errors, but little is known about the nature and causes of these events. We examined characteristics of technical errors and common contributing factors among closed surgical malpractice claims. Surgeon reviewers analyzed 444 randomly sampled surgical malpractice claims from four liability insurers. Among 258 claims in which injuries due to error were detected, 52% (n = 133) involved technical errors. These technical errors were further analyzed with a structured review instrument designed by qualitative content analysis. Forty-nine percent of the technical errors caused permanent disability; an additional 16% resulted in death. Two-thirds (65%) of the technical errors were linked to manual error, 9% to errors in judgment, and 26% to both manual and judgment error. A minority of technical errors involved advanced procedures requiring special training ("index operations"; 16%), surgeons inexperienced with the task (14%), or poorly supervised residents (9%). The majority involved experienced surgeons (73%), and occurred in routine, rather than index, operations (84%). Patient-related complexities-including emergencies, difficult or unexpected anatomy, and previous surgery-contributed to 61% of technical errors, and technology or systems failures contributed to 21%. Most technical errors occur in routine operations with experienced surgeons, under conditions of increased patient complexity or systems failure. Commonly recommended interventions, including restricting high-complexity operations to experienced surgeons, additional training for inexperienced surgeons, and stricter supervision of trainees, are likely to address only a minority of technical errors. Surgical safety research should instead focus on improving decision-making and performance in routine operations for complex patients and circumstances.

  17. Continued Validation of the O-SCORE (Ottawa Surgical Competency Operating Room Evaluation): Use in the Simulated Environment.

    PubMed

    MacEwan, Matthew J; Dudek, Nancy L; Wood, Timothy J; Gofton, Wade T

    2016-01-01

    CONSTRUCT: The Ottawa Surgical Competency Operating Room Evaluation (O-SCORE) is a 9-item surgical evaluation tool designed to assess technical competence in surgical trainees using behavioral anchors. The initial development of the O-SCORE produced evidence for valid results. Further work is required to determine if the use of a single surgeon or an unblinded rater introduces bias. In addition, the relationship of the O-SCORE to other currently used technical assessment tools should be explored to provide validity evidence related to the relationship to other measures. We have designed this project to provide continued validity evidence for the O-SCORE related to these two issues. Nineteen residents and 2 staff Orthopedic Surgeons from the University of Ottawa volunteered to participate in a 2-part OSCE style station. Participants completed a written questionnaire followed by a videotaped 10-minute simulated open reduction and internal fixation of a midshaft radius fracture. Videos were rated individually by 2 blinded staff orthopedic surgeons using an Objective Structured Assessment of Technical Skills (OSATS) global rating scale, an OSATS checklist, and the O-SCORE in random order. O-SCORE results appeared sensitive to surgical training level even when raters were blinded. In addition, strong agreement between two independent observers using the O-SCORE suggests that the measure captures a performance easily recognized by surgical observers. Ratings on the O-SCORE also were strongly associated with global ratings on the currently most validated technical evaluation tool (OSATS). Collectively, these results suggest that the O-SCORE generates accurate, reproducible, and meaningful results when used in a randomized and blinded fashion, providing continued validity evidence for using this tool to evaluate surgical trainee competence. The O-SCORE was able to differentiate surgical trainee level using blinded raters providing further evidence of validity for the O-SCORE. There was strong agreement between two independent observers using the O-SCORE. Ratings on the O-SCORE also demonstrated equivalence to scores on the most validated technical evaluation tool (OSATS). These results suggest that the O-SCORE demonstrates accurate and reproducible results when used in a randomized and blinded fashion providing continued validity evidence for this tool in the evaluation of surgical competence in the trainees.

  18. Factors that influence the non-technical skills performance of scrub nurses: a prospective study.

    PubMed

    Kang, Evelyn; Massey, Debbie; Gillespie, Brigid M

    2015-12-01

    To identify and describe the factors that impact on the performance of scrub nurses' non-technical skills performance during the intra-operative phase of surgery. Non-technical skills have been identified as important precursors to errors in the operating room. However, few studies have investigated factors influencing non-technical skills of scrub nurses. Prospective observational study. Structured observations were performed on a sample of 182 surgical procedures across eight specialities by two trained observers from August 2012-April 2013 at two hospital sites. Participants were purposively selected scrub nurses. Bivariate correlations and a multiple linear regression model were used to identify associations among length of surgery, patients' acuity using the American Society of Anesthesiologists classification system, team familiarity, number of occasions scout nurses leave the operating room, change of scout nurse and the outcome, the non-technical skills performance of scrub nurses. Patient acuity and team familiarity were the strongest predictors of scrub nurses' non-technical skills performance at hospital site A. There were no correlations between the predictors and the performance of scrub nurses at hospital site B. A dedicated surgical team and patient acuity potentially influence the performance of scrub nurses' non-technical skills. Familiarity with team members foster advanced planning, thus minimizing distractions and interruptions that impact on scrub nurses' performance. Development of interventions aimed at improving non-technical skills has the potential to make a substantial difference and enhance patient care. © 2015 John Wiley & Sons Ltd.

  19. Surgical timing after chemoradiotherapy for rectal cancer, analysis of technique (STARRCAT): results of a feasibility multi-centre randomized controlled trial.

    PubMed

    Foster, J D; Ewings, P; Falk, S; Cooper, E J; Roach, H; West, N P; Williams-Yesson, B A; Hanna, G B; Francis, N K

    2016-10-01

    The optimal time of rectal resection after long-course chemoradiotherapy (CRT) remains unclear. A feasibility study was undertaken for a multi-centre randomized controlled trial evaluating the impact of the interval after chemoradiotherapy on the technical complexity of surgery. Patients with rectal cancer were randomized to either a 6- or 12-week interval between CRT and surgery between June 2012 and May 2014 (ISRCTN registration number: 88843062). For blinded technical complexity assessment, the Observational Clinical Human Reliability Analysis technique was used to quantify technical errors enacted within video recordings of operations. Other measured outcomes included resection completeness, specimen quality, radiological down-staging, tumour cell density down-staging and surgeon-reported technical complexity. Thirty-one patients were enrolled: 15 were randomized to 6 and 16-12 weeks across 7 centres. Fewer eligible patients were identified than had been predicted. Of 23 patients who underwent resection, mean 12.3 errors were observed per case at 6 weeks vs. 10.7 at 12 weeks (p = 0.401). Other measured outcomes were similar between groups. The feasibility of measurement of operative performance of rectal cancer surgery as an endpoint was confirmed in this exploratory study. Recruitment of sufficient numbers of patients represented a challenge, and a proportion of patients did not proceed to resection surgery. These results suggest that interval after CRT may not substantially impact upon surgical technical performance.

  20. Exercise intensities during a ballet lesson in female adolescents with different technical ability.

    PubMed

    Guidetti, L; Gallotta, M C; Emerenziani, G P; Baldari, C

    2007-09-01

    To investigate the exercise intensity during a typical grade five ballet lesson, thirty-nine dancers (13 - 16 yrs) were divided into three different technical proficiency groups: low level (n = 13), intermediate level (n = 14), and high level (n = 12). A progressively incremented treadmill test was administered to determine VO(2max), individual ventilatory threshold (IVT), and the individual anaerobic threshold (IAT). Oxygen uptake (VO(2)), heart rate (HR) and blood lactate (La) were then evaluated during a grade five ballet lesson. Oxygen uptake at IVT, IAT and maximal oxygen uptake were greater (p < 0.05) in the high-level dancers indicating a higher level of fitness. HR and %VO(2max) obtained during the various exercises of the ballet lesson were similar among groups. During the ballet lesson, low technical level dancers had more V.O (2) and La values above (p < 0.05) the IAT than the other groups. Correlation analysis revealed that the number of exercises performed above IAT was positively related to anthropometric characteristics (BMI, %FM; r = 0.36, p < 0.05; r = 0.46, p < 0.01), negatively related to fitness parameters (VO(2IVT), VO(2IAT), VO(2max); r between - 0.43 and - 0.69; p < 0.001) and to technical level (r = - 0.70; p < 0.001). The subjects classified as having low technical abilities had lower fitness levels and performed more exercises above IAT than the more skilled dancers.

  1. Space Fence PDR Concept Development Phase

    NASA Astrophysics Data System (ADS)

    Haines, L.; Phu, P.

    2011-09-01

    The Space Fence, a major Air Force acquisition program, will become the dominant low-earth orbit uncued sensor in the space surveillance network (SSN). Its primary objective is to provide a 24/7 un-cued capability to find, fix, and track small objects in low earth orbit to include emerging and evolving threats, as well as the rapidly growing population of orbital debris. Composed of up to two geographically dispersed large-scale S-band phased array radars, this new system-of-systems concept will provide comprehensive Space Situational Awareness through net-centric operations and integrated decision support. Additionally, this program will facilitate cost saving force structure changes in the SSN, specifically including the decommissioning of very-high frequency VHF Air Force Space Surveillance System (AFSSS). The Space Fence Program Office entered a Preliminary Design Review (PDR) concept development phase in January 2011 to achieve the delivery of the Initial Operational Capability (IOC) expected in FY17. Two contractors were awarded to perform preliminary system design, conduct radar performance analyses and evaluations, and develop a functional PDR radar system prototype. The key objectives for the Phase A PDR effort are to reduce Space Fence total program technical, cost, schedule, and performance risk. The overall program objective is to achieve a preliminary design that demonstrates sufficient technical and manufacturing maturity and that represents a low risk, affordable approach to meet the Space Fence Technical Requirements Document (TRD) requirements for the final development and production phase to begin in 3QFY12. This paper provides an overview of the revised Space Fence program acquisition strategy for the Phase-A PDR phase to IOC, the overall program milestones and major technical efforts. In addition, the key system trade studies and modeling/simulation efforts undertaken during the System Design Requirement (SDR) phase to address and mitigate technical challenges of the Space Fence System will also be discussed. Examples include radar system optimization studies, modeling and simulation for system performance assessment, investigation of innovative Astrodynamics algorithms for initial orbit determination and observation correlation.

  2. 77 FR 37710 - Notice of Proposed Information Collection

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-22

    ... to continue the collection of information for two technical training program course effectiveness... approval. This collection is for OSM's Technical Training Program Course Effectiveness Evaluations (1029... collection activity: Title: Technical Training Program Course Effectiveness Evaluation. OMB Control Number...

  3. Quarterly Performance/Technical Report of the National Marrow Donor Program

    DTIC Science & Technology

    2008-02-05

    HLA-DRB1 High Resolution Typing Closed 9 IIB.1.3 Aim 3 – Evaluate HLA-C Typing of Donors Closed 9 IIB.1.4 Aim 4 – Evaluate Buccal Swabs Open 10 IIB...December 31, 2007 10 of 21 IIB.1.4 Aim 4: Evaluate Buccal Swabs Period 5 Activity: In April of 2006, the NMDP transitioned to the use of... buccal swabs for the collection of DNA samples from newly recruited donors. To support this change in sample type, Quality Control samples for donor

  4. Ultraviolet spectrometer and polarimeter (UVSP) software development and hardware tests for the solar maximum mission

    NASA Technical Reports Server (NTRS)

    Bruner, M. E.; Haisch, B. M.

    1986-01-01

    The Ultraviolet Spectrometer/Polarimeter Instrument (UVSP) for the Solar Maximum Mission (SMM) was based on the re-use of the engineering model of the high resolution ultraviolet spectrometer developed for the OSO-8 mission. Lockheed assumed four distinct responsibilities in the UVSP program: technical evaluation of the OSO-8 engineering model; technical consulting on the electronic, optical, and mechanical modifications to the OSO-8 engineering model hardware; design and development of the UVSP software system; and scientific participation in the operations and analysis phase of the mission. Lockheed also provided technical consulting and assistance with instrument hardware performance anomalies encountered during the post launch operation of the SMM observatory. An index to the quarterly reports delivered under the contract are contained, and serves as a useful capsule history of the program activity.

  5. Surgical Crisis Management Skills Training and Assessment

    PubMed Central

    Moorthy, Krishna; Munz, Yaron; Forrest, Damien; Pandey, Vikas; Undre, Shabnam; Vincent, Charles; Darzi, Ara

    2006-01-01

    Background: Intraoperative surgical crisis management is learned in an unstructured manner. In aviation, simulation training allows aircrews to coordinate and standardize recovery strategies. Our aim was to develop a surgical crisis simulation and evaluate its feasibility, realism, and validity of the measures used to assess performance. Methods: Surgical trainees were exposed to a bleeding crisis in a simulated operating theater. Assessment of performance consisted of a trainee’s technical ability to control the bleeding and of their team/human factors skills. This assessment was performed in a blinded manner by 2 surgeons and one human factors expert. Other measures consisted of time measures such as time to diagnose the bleeding (TD), inform team members (TT), achieve control (TC), and close the laceration (TL). Blood loss was used as a surrogate outcome measures. Results: There were considerable variations within both senior (n = 10) and junior (n = 10) trainees for technical and team skills. However, while the senior trainees scored higher than the juniors for technical skills (P = 0.001), there were no differences in human factors skills. There were also significant differences between the 2 groups for TD (P = 0.01), TC (P = 0.001), and TL (0.001). The blood loss was higher in the junior group. Conclusions: We have described the development of a novel simulated setting for the training of crisis management skills and the variability in performance both in between and within the 2 groups. PMID:16794399

  6. Is the technical performance of young soccer players influenced by hormonal status, sexual maturity, anthropometric profile, and physical performance?

    PubMed

    Moreira, Alexandre; Massa, Marcelo; Thiengo, Carlos R; Rodrigues Lopes, Rafael Alan; Lima, Marcelo R; Vaeyens, Roel; Barbosa, Wesley P; Aoki, Marcelo S

    2017-12-01

    The aim of this study was to examine the influence of hormonal status, anthropometric profile, sexual maturity level, and physical performance on the technical abilities of 40 young male soccer players during small-sided games (SSGs). Anthropometric profiling, saliva sampling, sexual maturity assessment (Tanner scale), and physical performance tests (Yo-Yo and vertical jumps) were conducted two weeks prior to the SSGs. Salivary testosterone was determined by the enzyme-linked immunosorbent assay method. Technical performance was determined by the frequency of actions during SSGs. Principal component analyses identified four technical actions of importance: total number of passes, effectiveness, goal attempts, and total tackles. A multivariate canonical correlation analysis was then employed to verify the prediction of a multiple dependent variables set (composed of four technical actions) from an independent set of variables, composed of testosterone concentration, stage of pubic hair and genitalia development, vertical jumps and Yo-Yo performance. A moderate-to-large relationship between the technical performance set and the independent set was observed. The canonical correlation was 0.75 with a canonical R 2 of 0.45. The highest structure coefficient in the technical performance set was observed for tackles (0.77), while testosterone presented the highest structure coefficient (0.75) for the variables of the independent set. The current data suggest that the selected independent set of variables might be useful in predicting SSG performance in young soccer players. Coaches should be aware that physical development plays a key role in technical performance to avoid decision-making mistakes during the selection of young players.

  7. Repair, Evaluation, Maintenance, and Rehabilitation Research Program: Factors Related to the Performance of Concrete Repair Materials.

    DTIC Science & Technology

    1988-03-01

    in reference HRS 78.) The ASTM C 883 effective shrinkage standard test method involves constructing a laminate consisting of an epoxy-resin system...Evaluation of a Hiah-Strenrth Polyester Snythetic Concrete, U.S. Army Construction Engineering Research Laboratory, CERL Technical Report M-2, Champaign...Colorado, August 1, 1983. Can 67 F. Canovas, (Effects of ) Temperature Ch anges on Epoxy Pavements, Informes de la construccion (Madrid), 19, No. 189, pp

  8. 48 CFR 1852.242-70 - Technical direction.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Direction (SEP 1993) (a) Performance of the work under this contract is subject to the written technical... the Contracting Officer in writing in accordance with NASA FAR Supplement 1842.270. “Technical... in writing by the COTR. (d) The Contractor shall proceed promptly with the performance of technical...

  9. 48 CFR 216.402-2 - Technical performance incentives.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Technical performance incentives. 216.402-2 Section 216.402-2 Federal Acquisition Regulations System DEFENSE ACQUISITION... Contracts 216.402-2 Technical performance incentives. See PGI 216.402-2 for guidance on establishing...

  10. Surveillance and Datalink Communication Performance Analysis for Distributed Separation Assurance System Architectures

    NASA Technical Reports Server (NTRS)

    Chung, William W.; Linse, Dennis J.; Alaverdi, Omeed; Ifarraguerri, Carlos; Seifert, Scott C.; Salvano, Dan; Calender, Dale

    2012-01-01

    This study investigates the effects of two technical enablers: Automatic Dependent Surveillance - Broadcast (ADS-B) and digital datalink communication, of the Federal Aviation Administration s Next Generation Air Transportation System (NextGen) under two separation assurance (SA) system architectures: ground-based SA and airborne SA, on overall separation assurance performance. Datalink performance such as successful reception probability in both surveillance and communication messages, and surveillance accuracy are examined in various operational conditions. Required SA performance is evaluated as a function of subsystem performance, using availability, continuity, and integrity metrics to establish overall required separation assurance performance, under normal and off-nominal conditions.

  11. Twenty-year perspective of randomized controlled trials for surgery of chronic nonspecific low back pain: citation bias and tangential knowledge.

    PubMed

    Andrade, Nicholas S; Flynn, John P; Bartanusz, Viktor

    2013-11-01

    After decades of clinical research, the role of surgery for chronic nonspecific low back pain (CNLBP) remains equivocal. Despite significant intellectual, human, and economic investments into randomized controlled trials (RCTs) in the past two decades, the role of surgery in the treatment for CNLBP has not been clarified. To delineate the historical research agenda of surgical RCTs for CNLBP performed between 1993 and 2012 investigating whether conclusions from earlier published trials influenced the choice of research questions of subsequent RCTs on elucidating the role of surgery in the management of CNLBP. Literature review. We searched the literature for all RCTs involving surgery for CNLBP. We reviewed relevant studies to identify the study question, comparator arms, and sample size. Randomized controlled trials were classified as "indication" trials if they evaluated the effectiveness of surgical therapy versus nonoperative care or as "technical" if they compared different surgical techniques, adjuncts, or procedures. We used citation analysis to determine the impact of trials on subsequent research in the field. Altogether 33 technical RCTs (3,790 patients) and 6 indication RCTs (981 patients) have been performed. Since 2007, despite the unclear benefits of surgery reported by the first four indication trials published in 2001 to 2006, technical trials have continued to predominate (16 vs. 2). Of the technical trials, types of instrumentation (13 trials, 1,332 patients), bone graft materials and substitutes (11 trials, 833 patients), and disc arthroplasty versus fusion (5 trials, 1,337 patients) were the most common comparisons made. Surgeon authors have predominantly cited one of the indication trials that reported more favorable results for surgery, despite a lack of superior methodology or sample size. Trials evaluating bone morphogenic protein, instrumentation, and disc arthroplasty were all cited more frequently than the largest trial of surgical versus nonsurgical therapy. The research agenda of RCTs for surgery of CNLBP has not changed substantially in the last 20 years. Technical trials evaluating nuances of surgical techniques significantly predominate. Despite the publication of four RCTs reporting equivocal benefits of surgery for CNLBP between 2001 and 2006, there was no change in the research agenda of subsequent RCTs, and technical trials continued to outnumber indication trials. Rather than clarifying what, if any, indications for surgery exist, investigators in the field continue to analyze variations in surgical technique, which will probably have relatively little impact on patient outcomes. As a result, clinicians unfortunately have little evidence to advise patients regarding surgical intervention for CNLBP. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. Space Storable Propellant Performance Gas/Liquid Like-Doublet Injector Characterization

    NASA Technical Reports Server (NTRS)

    Falk, A. Y.

    1972-01-01

    A 30-month applied research program was conducted, encompassing an analytical, design, and experimental effort to relate injector design parameters to simultaneous attainment of high performance and component (injector/thrust chamber) compatibility for gas/liquid space-storable propellants. The gas/liquid propellant combination selected for study was FLOX (82.6% F2)/ambient temperature gaseous methane. The injector pattern characterized was the like-(self)-impinging doublet. Program effort was apportioned into four basic technical tasks: injector and thrust chamber design, injector and thrust chamber fabrication, performance evaluation testing, and data evaluation and reporting. Analytical parametric combustion analyses and cold flow distribution and atomization experiments were conducted with injector segment models to support design of injector/thrust chamber combinations for hot fire evaluation. Hot fire tests were conducted to: (1) optimize performance of the injector core elements, and (2) provide design criteria for the outer zone elements so that injector/thrust chamber compatibility could be achieved with only minimal performance losses.

  13. Industrial laser welding evaluation study

    NASA Technical Reports Server (NTRS)

    Hella, R.; Locke, E.; Ream, S.

    1974-01-01

    High power laser welding was evaluated for fabricating space vehicle boosters. This evaluation was made for 1/4 in. and 1/2 in. aluminum (2219) and 1/4 in. and 1/2 in. D6AC steel. The Avco HPL 10 kW industrial laser was used to perform the evaluation. The objective has been achieved through the completion of the following technical tasks: (1) parameter study to optimize welding and material parameters; (2) preparation of welded panels for MSFC evaluation; and (3) demonstration of the repeatability of laser welding equipment. In addition, the design concept for a laser welding system capable of welding large space vehicle boosters has been developed.

  14. JT9D engine diagnostics. Task 2: Feasibility study of measuring in-service flight loads. [747 aircraft performance

    NASA Technical Reports Server (NTRS)

    Kafka, P. G.; Skibo, M. A.; White, J. L.

    1977-01-01

    The feasibility of measuring JT9D propulsion system flight inertia loads on a 747 airplane is studied. Flight loads background is discussed including the current status of 747/JT9D loads knowledge. An instrumentation and test plan is formulated for an airline-owned in-service airplane and the Boeing-owned RA001 test airplane. Technical and cost comparisons are made between these two options. An overall technical feasibility evaluation is made and a cost summary presented. Conclusions and recommendations are presented in regard to using existing inertia loads data versus conducting a flight test to measure inertia loads.

  15. Improved technical performance of a multifunctional prehospital telemedicine system between the research phase and the routine use phase - an observational study.

    PubMed

    Felzen, Marc; Brokmann, Jörg C; Beckers, Stefan K; Czaplik, Michael; Hirsch, Frederik; Tamm, Miriam; Rossaint, Rolf; Bergrath, Sebastian

    2017-04-01

    Introduction Telemedical concepts in emergency medical services (EMS) lead to improved process times and patient outcomes, but their technical performance has thus far been insufficient; nevertheless, the concept was transferred into EMS routine care in Aachen, Germany. This study evaluated the system's technical performance and compared it to a precursor system. Methods The telemedicine system was implemented on seven ambulances and a teleconsultation centre staffed with experienced EMS physicians was established in April 2014. Telemedical applications included mobile vital data, 12-lead, picture transmission and video streaming from inside the ambulances. The tele-EMS physician filled in a questionnaire regarding the technical performance of the applications, background noise and assessed clinical values of the transmitted pictures and videos after each mission between 15 May 2014-15 October 2014. Results Teleconsultation was established during 539 emergency cases. In 83% of the cases ( n = 447), only the paramedics and the tele-EMS physician were involved. Transmission success rates ranged from 98% (audio connection) to 93% (12-lead electrocardiogram (ECG) transmission). All functionalities, except video transmission, were significantly better than the pilot project ( p < 0.05). Severe background noise was detected to a lesser extent ( p = 0.0004) and the clinical value of the pictures and videos were considered significantly more valuable. Discussion The multifunctional system is now sufficient for routine use and is the most reliable mobile emergency telemedicine system compared to other published projects. Dropouts were due to user errors and network coverage problems. These findings enable widespread use of this system in the future, reducing the critical time intervals until medical therapy is started.

  16. The effect of teamwork training on team performance and clinical outcome in elective orthopaedic surgery: a controlled interrupted time series study.

    PubMed

    Morgan, Lauren; Hadi, Mohammed; Pickering, Sharon; Robertson, Eleanor; Griffin, Damian; Collins, Gary; Rivero-Arias, Oliver; Catchpole, Ken; McCulloch, Peter; New, Steve

    2015-04-20

    To evaluate the effectiveness of aviation-style teamwork training in improving operating theatre team performance and clinical outcomes. 3 operating theatres in a UK district general hospital, 1 acting as a control group and the other 2 as the intervention group. 72 operations (37 intervention, 35 control) were observed in full by 2 trained observers during two 3-month observation periods, before and after the intervention period. A 1-day teamwork training course for all staff, followed by 6 weeks of weekly in-service coaching to embed learning. We measured team non-technical skills using Oxford NOTECHS II, (evaluating the whole team and the surgical, anaesthetic and nursing subteams, and evaluated technical performance using the Glitch count. We evaluated compliance with the WHO checklist by recording whether time-out (T/O) and sign-out (S/O) were attempted, and whether T/O was fully complied with. We recorded complications, re-admissions and duration of hospital stay using hospital administrative data. We compared the before-after change in the intervention and control groups using 2-way analysis of variance (ANOVA) and regression modelling. Mean NOTECHS II score increased significantly from 71.6 to 75.4 in the active group but remained static in the control group (p=0.047). Among staff subgroups, the nursing score increased significantly (p=0.006), but the anaesthetic and surgical scores did not. The attempt rate for WHO T/O procedures increased significantly in both active and control groups, but full compliance with T/O improved only in the active group (p=0.003). Mean glitch rate was unchanged in the control group but increased significantly (7.2-10.2/h, p=0.002) in the active group. Teamwork training was associated with improved non-technical skills in theatre teams but also with a rise in operative glitches. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  17. Study of Synthetic Vision Systems (SVS) and Velocity-vector Based Command Augmentation System (V-CAS) on Pilot Performance

    NASA Technical Reports Server (NTRS)

    Liu, Dahai; Goodrich, Ken; Peak, Bob

    2006-01-01

    This study investigated the effects of synthetic vision system (SVS) concepts and advanced flight controls on single pilot performance (SPP). Specifically, we evaluated the benefits and interactions of two levels of terrain portrayal, guidance symbology, and control-system response type on SPP in the context of lower-landing minima (LLM) approaches. Performance measures consisted of flight technical error (FTE) and pilot perceived workload. In this study, pilot rating, control type, and guidance symbology were not found to significantly affect FTE or workload. It is likely that transfer from prior experience, limited scope of the evaluation task, specific implementation limitations, and limited sample size were major factors in obtaining these results.

  18. Digital electronic engine control history

    NASA Technical Reports Server (NTRS)

    Putnam, T. W.

    1984-01-01

    Full authority digital electronic engine controls (DEECs) were studied, developed, and ground tested because of projected benefits in operability, improved performance, reduced maintenance, improved reliability, and lower life cycle costs. The issues of operability and improved performance, however, are assessed in a flight test program. The DEEC on a F100 engine in an F-15 aircraft was demonstrated and evaluated. The events leading to the flight test program are chronicled and important management and technical results are identified.

  19. Training safer orthopedic surgeons. Construct validation of a virtual-reality simulator for hip fracture surgery.

    PubMed

    Akhtar, Kashif; Sugand, Kapil; Sperrin, Matthew; Cobb, Justin; Standfield, Nigel; Gupte, Chinmay

    2015-01-01

    Virtual-reality (VR) simulation in orthopedic training is still in its infancy, and much of the work has been focused on arthroscopy. We evaluated the construct validity of a new VR trauma simulator for performing dynamic hip screw (DHS) fixation of a trochanteric femoral fracture. 30 volunteers were divided into 3 groups according to the number of postgraduate (PG) years and the amount of clinical experience: novice (1-4 PG years; less than 10 DHS procedures); intermediate (5-12 PG years; 10-100 procedures); expert (> 12 PG years; > 100 procedures). Each participant performed a DHS procedure and objective performance metrics were recorded. These data were analyzed with each performance metric taken as the dependent variable in 3 regression models. There were statistically significant differences in performance between groups for (1) number of attempts at guide-wire insertion, (2) total fluoroscopy time, (3) tip-apex distance, (4) probability of screw cutout, and (5) overall simulator score. The intermediate group performed the procedure most quickly, with the lowest fluoroscopy time, the lowest tip-apex distance, the lowest probability of cutout, and the highest simulator score, which correlated with their frequency of exposure to running the trauma lists for hip fracture surgery. This study demonstrates the construct validity of a haptic VR trauma simulator with surgeons undertaking the procedure most frequently performing best on the simulator. VR simulation may be a means of addressing restrictions on working hours and allows trainees to practice technical tasks without putting patients at risk. The VR DHS simulator evaluated in this study may provide valid assessment of technical skill.

  20. Teleoperator technology and system development, volume 1

    NASA Technical Reports Server (NTRS)

    1972-01-01

    A two phase approach was undertaken to: (1) evaluate the performance of a general-purpose anthropomorphic manipulator with various controllers and display arrangements, (2) identify basic technical limitations of existing teleoperator designs, and associated controls and displays, and (3) identify, through experimentation, the effects that controls and displays have on the performance of an anthropomorphic manipulator. In Phase 1 the NASA-furnished manipulators, controls and displays were integrated with the remote maneuvering unit; in Phase 2 experiments were defined and performed to assess the utility of teleoperators for 6 typical space inspection, maintenance and repair tasks.

  1. Performance Management and Optimization of Semiconductor Design Projects

    NASA Astrophysics Data System (ADS)

    Hinrichs, Neele; Olbrich, Markus; Barke, Erich

    2010-06-01

    The semiconductor industry is characterized by fast technological changes and small time-to-market windows. Improving productivity is the key factor to stand up to the competitors and thus successfully persist in the market. In this paper a Performance Management System for analyzing, optimizing and evaluating chip design projects is presented. A task graph representation is used to optimize the design process regarding time, cost and workload of resources. Key Performance Indicators are defined in the main areas cost, profit, resources, process and technical output to appraise the project.

  2. Prospective Multicenter Study on the Challenges Inherent to Using Large Cell-Type Stents for Bilateral Stent-in-Stent Placement in Patients with Inoperable Malignant Hilar Biliary Obstruction.

    PubMed

    Yang, Min Jae; Kim, Jin Hong; Hwang, Jae Chul; Yoo, Byung Moo; Lee, Sang Hyub; Ryu, Ji Kon; Kim, Yong-Tae; Woo, Sang Myung; Lee, Woo Jin; Jeong, Seok; Lee, Don Haeng

    2018-06-22

    Although endoscopic bilateral stent-in-stent placement is challenging, many recent studies have reported promising outcomes regarding technical success and endoscopic reintervention. This study aimed to evaluate the technical feasibility of stent-in-stent placement using large cell-type stents in patients with inoperable malignant hilar biliary obstruction. Forty-three patients with inoperable malignant hilar biliary obstruction from four academic centers were prospectively enrolled from March 2013 to June 2015. Bilateral stent-in-stent placement using two large cell-type stents was successfully performed in 88.4% of the patients (38/43). In four of the five cases with technical failure, the delivery sheath of the second stent became caught in the hook-cross-type vertex of the large cell of the first stent, and subsequent attempts to pass a guidewire and stent assembly through the mesh failed. Functional success was achieved in all cases with technical success. Stent occlusion occurred in 63.2% of patients (24/38), with a median patient survival of 300 days. The median stent patency was 198 days. The stent patency rate was 82.9%, 63.1%, and 32.1% at 3, 6, and 12 months, respectively. Endoscopic re-intervention was performed in 14 patients, whereas 10 underwent percutaneous drainage. Large cell-type stents for endoscopic bilateral stent-in-stent placement showed acceptable functional success and stent patency when technically successful. However, the technical difficulty associated with the entanglement of the second stent delivery sheath in the hook-cross-type vertex of the first stent may preclude large cell-type stents from being considered as a dedicated standard tool for stent-in-stent placement.

  3. Nuclear thermal propulsion transportation systems for lunar/Mars exploration

    NASA Technical Reports Server (NTRS)

    Clark, John S.; Borowski, Stanley K.; Mcilwain, Melvin C.; Pellaccio, Dennis G.

    1992-01-01

    Nuclear thermal propulsion technology development is underway at NASA and DoE for Space Exploration Initiative (SEI) missions to Mars, with initial near-earth flights to validate flight readiness. Several reactor concepts are being considered for these missions, and important selection criteria will be evaluated before final selection of a system. These criteria include: safety and reliability, technical risk, cost, and performance, in that order. Of the concepts evaluated to date, the Nuclear Engine for Rocket Vehicle Applications (NERVA) derivative (NDR) is the only concept that has demonstrated full power, life, and performance in actual reactor tests. Other concepts will require significant design work and must demonstrate proof-of-concept. Technical risk, and hence, development cost should therefore be lowest for the concept, and the NDR concept is currently being considered for the initial SEI missions. As lighter weight, higher performance systems are developed and validated, including appropriate safety and astronaut-rating requirements, they will be considered to support future SEI application. A space transportation system using a modular nuclear thermal rocket (NTR) system for lunar and Mars missions is expected to result in significant life cycle cost savings. Finally, several key issues remain for NTR's, including public acceptance and operational issues. Nonetheless, NTR's are believed to be the 'next generation' of space propulsion systems - the key to space exploration.

  4. Can internal medicine residents master microscopic urinalysis? Results of an evaluation and teaching intervention.

    PubMed

    Canaris, Gay J; Flach, Stephen D; Tape, Thomas G; Stierwalt, Kathyrn M; Haggstrom, David A; Wigton, Robert S

    2003-05-01

    Although microscopic urinalysis (micro UA) is commonly used in clinical practice, and residents are trained in micro UA, proficiency in this procedure has not been studied. In 1996-97, 38 residents in the University of Nebraska Medical Center's internal medicine (IM) residency program were evaluated on their technical ability to perform micro UA, and on their cognitive skills in recognizing common micro UA findings. After identifying deficits in the residents' cognitive competency, two educational interventions were applied and residents were tested after each intervention. A total of 24 residents (63%) correctly prepared the specimen for analysis (the technical portion). On the cognitive portion, only one of the 38 residents correctly identified 80% of all micro UA findings in the urinary sediment, although 11 (29%) residents identified UA findings specific to urinary tract infection (UTI). The first educational intervention did little to improve residents' performance. A second more intensive intervention resulted in 10 (45%) residents identifying 80% of all micro UA findings, and 19 (86%) residents correctly identifying UTI findings. Many residents were not proficient in performing micro UA, even after intensive educational interventions. Although micro UA is a simple procedure, residents' mastery cannot be assumed. Residency programs should assess competency in this procedure.

  5. Impact of Nuclear Laboratory Personnel Credentials & Continuing Education on Nuclear Cardiology Laboratory Quality Operations.

    PubMed

    Malhotra, Saurabh; Sobieraj, Diana M; Mann, April; Parker, Matthew W

    2017-12-22

    Background/Objectives: The specific credentials and continuing education (CME/CE) of nuclear cardiology laboratory medical and technical staff are important factors in the delivery of quality imaging services that have not been systematically evaluated. Methods: Nuclear cardiology accreditation application data from the Intersocietal Accreditation Commission (IAC) was used to characterize facilities performing myocardial perfusion imaging by setting, size, previous accreditation and credentials of the medical and technical staff. Credentials and CME/CE were compared against initial accreditation decisions (grant or delay) using multivariable logistic regression. Results: Complete data were available for 1913 nuclear cardiology laboratories from 2011-2014. Laboratories with initial positive accreditation decisions had a greater prevalence of Certification Board in Nuclear Cardiology (CBNC) certified medical directors and specialty credentialed technical directors. Certification and credentials of the medical and technical directors, respectively, staff CME/CE compliance, and assistance of a consultant with the application were positively associated with accreditation decisions. Conclusion: Nuclear cardiology laboratories directed by CBNC-certified physicians and NCT- or PET-credentialed technologists were less likely to receive delay decisions for MPI. CME/CE compliance of both the medical and technical directors was associated with accreditation decision. Medical and technical directors' years of experience were not associated with accreditation decision. Copyright © 2017 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  6. The Evaluation of the Effectiveness of ESP Courses in Enhancing Technical Translation Proficiency: A Case Study of ESP Course for Mechanical Engineering Students

    ERIC Educational Resources Information Center

    Hatam, Amir Hussein; Shafiei, Shilan

    2012-01-01

    The purpose of the present study was twofold. Firstly, it tried to investigate the relationship between the technical English proficiency of the students of Mechanical Engineering in the universities of Iran and their technical translation proficiency in translating technical texts of Mechanics. Secondly, it attempted to evaluate the effectiveness…

  7. A Review and Evaluation of the Langley Research Center's Scientific and Technical Information Program. Results of Phase VI-The Technical Report: A Survey and Analysis.

    ERIC Educational Resources Information Center

    McCullough, Robert A.; And Others

    This report presents the results of a review and evaluation of the Langley Research Center's scientific and technical information program, which examined technical reports from various institutions and organizations to determine the organization of reports, the language used to convey information, and the methods used to present information.…

  8. 48 CFR 1816.402-270 - NASA technical performance incentives.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 6 2013-10-01 2013-10-01 false NASA technical performance incentives. 1816.402-270 Section 1816.402-270 Federal Acquisition Regulations System NATIONAL AERONAUTICS AND....402-270 NASA technical performance incentives. (a) Pursuant to the guidelines in 1816.402, NASA has...

  9. 48 CFR 1816.402-270 - NASA technical performance incentives.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true NASA technical performance incentives. 1816.402-270 Section 1816.402-270 Federal Acquisition Regulations System NATIONAL AERONAUTICS AND....402-270 NASA technical performance incentives. (a) Pursuant to the guidelines in 1816.402, NASA has...

  10. 48 CFR 1816.402-270 - NASA technical performance incentives.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 6 2014-10-01 2014-10-01 false NASA technical performance incentives. 1816.402-270 Section 1816.402-270 Federal Acquisition Regulations System NATIONAL AERONAUTICS AND....402-270 NASA technical performance incentives. (a) Pursuant to the guidelines in 1816.402, NASA has...

  11. 48 CFR 1816.402-270 - NASA technical performance incentives.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 6 2011-10-01 2011-10-01 false NASA technical performance incentives. 1816.402-270 Section 1816.402-270 Federal Acquisition Regulations System NATIONAL AERONAUTICS AND....402-270 NASA technical performance incentives. (a) Pursuant to the guidelines in 1816.402, NASA has...

  12. 48 CFR 1816.402-270 - NASA technical performance incentives.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 6 2012-10-01 2012-10-01 false NASA technical performance incentives. 1816.402-270 Section 1816.402-270 Federal Acquisition Regulations System NATIONAL AERONAUTICS AND....402-270 NASA technical performance incentives. (a) Pursuant to the guidelines in 1816.402, NASA has...

  13. Participatory evaluation of delivery of animal health care services by community animal health workers in Karamoja region of Uganda.

    PubMed

    Bugeza, James; Kankya, Clovice; Muleme, James; Akandinda, Ann; Sserugga, Joseph; Nantima, Noelina; Okori, Edward; Odoch, Terence

    2017-01-01

    An evaluation exercise was carried out to assess the performance of Community Animal Health Workers (CAHWs) in the delivery of animal health care services in Karamoja region, identify capacity gaps and recommend remedial measures. Participatory methods were used to design data collection tools. Questionnaires were administered to 204 CAHWs, 215 farmers and 7 District Veterinary Officers (DVOs) to collect quantitative data. Seven DVOs and 1 Non Government Organization (NGO) representative were interviewed as key informants and one focus group discussion was conducted with a farmer group in Nakapiripirit to collect qualitative data. Questionnaire data was analyzed using SPSS version 19. Key messages from interviews and the focus group discussion were recorded in a notebook and reported verbatim. 70% of the farmers revealed that CAHWs are the most readily available animal health care service providers in their respective villages. CAHWs were instrumental in treatment of sick animals, disease surveillance, control of external parasites, animal production, vaccination, reporting, animal identification, and performing minor surgeries. Regarding their overall performance 88.8%(191/215) of the farmers said they were impressed. The main challenges faced by the CAHWs were inadequate facilitation, lack of tools and equipments, unwillingness of government to integrate them into the formal extension system, poor information flow, limited technical capacity to diagnose diseases, unwillingness of farmers to pay for services and sustainability issues. CAHWs remain the main source of animal health care services in Karamoja region and their services are largely satisfactory. The technical deficits identified require continuous capacity building programs, close supervision and technical backstopping. For sustainability of animal health care services in the region continuous training and strategic deployment of paraprofessionals that are formally recognised by the traditional civil service to gradually replace CAHWs is recommended.

  14. One versus two venous anastomoses in microvascular lower extremity reconstruction using gracilis muscle or anterolateral thigh flaps.

    PubMed

    Heidekrueger, Paul I; Ehrl, Denis; Heine-Geldern, Albrecht; Ninkovic, Milomir; Broer, P Niclas

    2016-12-01

    Free tissue transfers are a highly reliable procedure routinely performed for reconstruction of a wide range of defects. Main complication in free flap surgery is usually venous thrombosis. Many technical controversies exist regarding the technical details of the microvascular anastomosis in order to prevent occurrence of thrombosis and optimize outcomes. We therefore evaluated our results regarding the execution of one versus two venous anastomoses in a variety of free flaps (fasciocutaneous- or muscle free flap) utilized for lower limb reconstruction. Between 2009 and 2015, 354 patients underwent 386 free ALT- or gracilis flaps for lower limb defect reconstruction after trauma, infection, or malignancies at our institution. The data was retrospectively screened for patients' demographics, perioperative details, flap survival, and surgical complications. The cases were divided into two groups regarding the number of microsurgically performed venous anastomosis: one versus two veins. Regarding the preoperative evaluation, there were no significant differences regarding comorbidities between the two groups. Overall, there was no significant difference regarding the rate of major (1 vein: 20.38% versus 2 veins: 18.78%, p>0.05) and minor (1 vein: 1.27% versus 2 veins: 2.18%, p>0.05) surgical complications during our 3-months follow-up period. Major complications included total flap losses of 5.73% (1 vein) versus 8.78% (2 veins). This study analyzed a large series of microsurgical reconstructions, with a focus on the impact of the number of venous anastomosis. The findings suggest that successful free tissue transfer for lower limb reconstruction can be achieved independent of the number of venous anastomoses, however two should be performed when technically feasible. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Final Technical Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stoessel, Chris

    2013-11-13

    This project developed a new high-performance R-10/high SHGC window design, reviewed market positioning and evaluated manufacturing solutions required for broad market adoption. The project objectives were accomplished by: identifying viable technical solutions based on modeling of modern and potential coating stacks and IGU designs; development of new coating material sets for HM thin film stacks, as well as improved HM IGU designs to accept multiple layers of HM films; matching promising new coating designs with new HM IGU designs to demonstrate performance gains; and, in cooperation with a window manufacturer, assess the potential for high-volume manufacturing and cost efficiency ofmore » a HM-based R-10 window with improved solar heat gain characteristics. A broad view of available materials and design options was applied to achieve the desired improvements. Gated engineering methodologies were employed to guide the development process from concept generation to a window demonstration. The project determined that a slightly de-rated window performance allows formulation of a path to achieve the desired cost reductions to support end consumer adoption.« less

  16. Macromolecule mass spectrometry: citation mining of user documents.

    PubMed

    Kostoff, Ronald N; Bedford, Clifford D; del Río, J Antonio; Cortes, Héctor D; Karypis, George

    2004-03-01

    Identifying research users, applications, and impact is important for research performers, managers, evaluators, and sponsors. Identification of the user audience and the research impact is complex and time consuming due to the many indirect pathways through which fundamental research can impact applications. This paper identified the literature pathways through which two highly-cited papers of 2002 Chemistry Nobel Laureates Fenn and Tanaka impacted research, technology development, and applications. Citation Mining, an integration of citation bibliometrics and text mining, was applied to the >1600 first generation Science Citation Index (SCI) citing papers to Fenn's 1989 Science paper on Electrospray Ionization for Mass Spectrometry, and to the >400 first generation SCI citing papers to Tanaka's 1988 Rapid Communications in Mass Spectrometry paper on Laser Ionization Time-of-Flight Mass Spectrometry. Bibliometrics was performed on the citing papers to profile the user characteristics. Text mining was performed on the citing papers to identify the technical areas impacted by the research, and the relationships among these technical areas.

  17. Technical Testing of the Wristwatch Size Automatic Physiological and Environmental Monitor (WAPEM): Laboratory and Outdoor Evaluations of Environmental Sensors Performance

    DTIC Science & Technology

    2004-03-01

    relative humidity (RH), ambient temperature (Ta), solar radiation (SR), and human activity in a small, water- resistant, durable enclosure. It is fitted...temperature, SR, and human activity . The activity channel is designed to function for sleep scoring (ZGM), as well as monitoring daytime activity with the

  18. THE FATE OF TRACE METALS IN A ROTARY KILN INCINERATOR WITH A VENTURI/PACKED COLUMN SCRUBBER - VOLUME I: TECHNICAL RESULTS

    EPA Science Inventory

    A five week series of pilot-scale incineration tests, using a synthetic waste feed, was performed at the Environmental Protection Agency's Incineration Research Facility to evaluate the fate of trace metals fed to a rotary kiln incinerator. Eight tests studied the fate of five ha...

  19. Aeronautical Engineering: A Continuing Bibliography with indexes

    NASA Technical Reports Server (NTRS)

    1984-01-01

    This bibliography lists 426 reports, articles and other documents introduced into the NASA scientific and technical information system in August 1984. Reports are cited in the area of Aeronautical Engineering. The coverage includes documents on the engineering and theoretical aspects of design, construction, evaluation, testing operation and performance of aircraft (including aircraft engines) and associated components, equipment and systems.

  20. Technical Evaluation Report

    DTIC Science & Technology

    2009-10-01

    of biological , behavioral & socio-cultural knowledge for the purposes of understanding those capabilities and limitations of relevance to the...However, HPM and HPO manipulations are not immune to bioethical dilemmas. With the burgeoning use of nutraceuticals, 1 control of soldiers’ diet...on the symposium recommendation and will be convening an exploratory team to discuss performance-related bioethical issues. The team will be

  1. FATE OF TRACE METALS IN A ROTARY KILN INCINERATOR WITH A SINGLE-STAGE IONIZING WET SCRUBBER. VOLUME 1. TECHNICAL RESULTS.

    EPA Science Inventory

    A series of pilot-scale incineration tests was performed at EPA's Incineration Research Facility (IRF) in Jefferson, Arkansas, to evaluate the fate of trace metals fed to a rotary kiln incinerator equipped with an ionizing wet scrubber (IWS) for particulate and acid gas control. ...

  2. Evaluating selected demographic factors related to consumer preferences for furniture from commercial and from underutilized species

    Treesearch

    David Nicholls; Matthew Bumgardner

    2007-01-01

    This technical note describes consumer preferences within selected demographic categories in two major Pacific Northwest markets for six domestic wood species. These woods were considered for construction of four furniture pieces. Chi-square tests were performed to determine species preferences based on gender, age, and income. Age and income were statistically...

  3. Evaluating selected demographic factors related to consumer preferences for furniture from commercial and from underutilized species.

    Treesearch

    David Nicholls; Matthew Bumgardner

    2007-01-01

    This technical note describes consumer preferences within selected demographic categories in two major Pacific Northwest markets for six domestic wood species. These woods were considered for construction of four furniture pieces. Chi-square tests were performed to determine species preferences based on gender, age, and income. Age and income were statistically...

  4. DESIGN AND TESTING OF SUB-SLAB DEPRESSURIZATION FOR RADON MITIGATION IN NORTH FLORIDA HOUSES - PART I. PERFORMANCE AND DURABILITY - VOLUME 1. TECHNICAL REPORT

    EPA Science Inventory

    The report gives results of a demonstration/research project to evaluate sub-slab depressurization (SSD) techniques for radon mitigation in North Florida where the housing stock is primarily slab-on-grade and the sub-slab medium typically consists of native soil and sand. Objecti...

  5. FIELD PERFORMANCE OF ADVANCED TECHNOLOGY WOODSTOVES IN GLEN FALLS, NY, 1988-89 - VOLUME II - TECHNICAL APPENDICES

    EPA Science Inventory

    The report gives results of an evaluation of particulate emission trends for three models of catalytic and two models of non- catalytic woodstoves under "in-home" burning conditions during the 1988-89 heating season in Glens Falls, NY. The results (averaging 9.4 g/h and 9.4 g/kg...

  6. Aeronautical Engineering: A continuing bibliography

    NASA Technical Reports Server (NTRS)

    1982-01-01

    This bibliography lists 347 reports, articles and other documents introduced into the scientific and technical information system. Documents on the engineering and theoretical aspects of design, construction, evaluation, testing, operation, and performance of aircraft (including aircraft engines) and associated compounds, equipment, and systems are included. Research and development in aerodynamics, aeronautics and ground support equipment for aeronautical vehicles are also included.

  7. Evaluating the Technical and Economic Performance of PV Plus Storage Power Plants: Report Summary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Denholm, Paul L.; Margolis, Robert M.; Eichman, Joshua D.

    The decreasing costs of both PV and energy storage technologies have raised interest in the creation of combined PV plus storage systems to provide dispatchable energy and reliable capacity. In this study, we examine the tradeoffs among various PV plus storage configurations and quantify the impact of configuration on system net value.

  8. Evaluating the Technical and Economic Performance of PV Plus Storage Power Plants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Denholm, Paul L.; Margolis, Robert M.; Eichman, Joshua D.

    The decreasing costs of both PV and energy storage technologies have raised interest in the creation of combined PV plus storage systems to provide dispatchable energy and reliable capacity. In this study, we examine the tradeoffs among various PV plus storage configurations and quantify the impact of configuration on system net value.

  9. Real-time endoscopic image orientation correction system using an accelerometer and gyrosensor.

    PubMed

    Lee, Hyung-Chul; Jung, Chul-Woo; Kim, Hee Chan

    2017-01-01

    The discrepancy between spatial orientations of an endoscopic image and a physician's working environment can make it difficult to interpret endoscopic images. In this study, we developed and evaluated a device that corrects the endoscopic image orientation using an accelerometer and gyrosensor. The acceleration of gravity and angular velocity were retrieved from the accelerometer and gyrosensor attached to the handle of the endoscope. The rotational angle of the endoscope handle was calculated using a Kalman filter with transmission delay compensation. Technical evaluation of the orientation correction system was performed using a camera by comparing the optical rotational angle from the captured image with the rotational angle calculated from the sensor outputs. For the clinical utility test, fifteen anesthesiology residents performed a video endoscopic examination of an airway model with and without using the orientation correction system. The participants reported numbers written on papers placed at the left main, right main, and right upper bronchi of the airway model. The correctness and the total time it took participants to report the numbers were recorded. During the technical evaluation, errors in the calculated rotational angle were less than 5 degrees. In the clinical utility test, there was a significant time reduction when using the orientation correction system compared with not using the system (median, 52 vs. 76 seconds; P = .012). In this study, we developed a real-time endoscopic image orientation correction system, which significantly improved physician performance during a video endoscopic exam.

  10. Report on the oversight assessment of the operational readiness review of the Replacement Tritium Facility at Savannah River Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, B.T.

    1993-03-01

    This report presents the results of an oversight assessment (OA) conducted by the US Department of Energy's (DOE) Office of Environment, Safety and Health (EH) of operational readiness review (ORR) activities for the Replacement Tritium Facility (RTF) located at Savannah River Site (SRS). The EH OA of this facility took place concurrently with an ORR conducted by the DOE Office of Defense Programs (DP). The DP ORR was conducted from January 19 through February 5, 1993. The EH OA was performed in accordance with the protocol and procedures specified in EH Program for Oversight Assessment of Operational Readiness Evaluations formore » Startups and Restarts,'' dated September 15, 1992. The EH OA Team evaluated the DP ORR to determine whether it was thorough and demonstrated sufficient inquisitiveness to verify that the implementation of programs and procedures adequately ensures the protection of worker safety and health. The EH OA Team performed its evaluation of the DP ORR in the following technical areas: occupational safety, industrial hygiene, and respiratory protection; fire protection; and chemical safety. In the areas of fire protection and chemical safety, the EH OA Team conducted independent vertical-slice reviews to confirm DP ORR results. Within each technical area, the EH OA Team reviewed the DP ORR Plan, including the Criteria Review and Approach Documents (CRADs); the qualifications of individual DP ORR team members; the performance of planned DP ORR activities; and the results of the DP ORR.« less

  11. Report on the oversight assessment of the operational readiness review of the Replacement Tritium Facility at Savannah River Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, B.T.

    1993-03-01

    This report presents the results of an oversight assessment (OA) conducted by the US Department of Energy`s (DOE) Office of Environment, Safety and Health (EH) of operational readiness review (ORR) activities for the Replacement Tritium Facility (RTF) located at Savannah River Site (SRS). The EH OA of this facility took place concurrently with an ORR conducted by the DOE Office of Defense Programs (DP). The DP ORR was conducted from January 19 through February 5, 1993. The EH OA was performed in accordance with the protocol and procedures specified in ``EH Program for Oversight Assessment of Operational Readiness Evaluations formore » Startups and Restarts,`` dated September 15, 1992. The EH OA Team evaluated the DP ORR to determine whether it was thorough and demonstrated sufficient inquisitiveness to verify that the implementation of programs and procedures adequately ensures the protection of worker safety and health. The EH OA Team performed its evaluation of the DP ORR in the following technical areas: occupational safety, industrial hygiene, and respiratory protection; fire protection; and chemical safety. In the areas of fire protection and chemical safety, the EH OA Team conducted independent vertical-slice reviews to confirm DP ORR results. Within each technical area, the EH OA Team reviewed the DP ORR Plan, including the Criteria Review and Approach Documents (CRADs); the qualifications of individual DP ORR team members; the performance of planned DP ORR activities; and the results of the DP ORR.« less

  12. 7 CFR Exhibit B-1 to Subpart I of... - Instructions for Preparation of Evaluation Report of Self-Help Technical Assistance Grants

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... to Subpart I of Part 1944—Instructions for Preparation of Evaluation Report of Self-Help Technical... 7 Agriculture 13 2013-01-01 2013-01-01 false Instructions for Preparation of Evaluation Report of Self-Help Technical Assistance Grants B Exhibit B-1 to Subpart I of Part 1944 Agriculture Regulations...

  13. 7 CFR Exhibit B-1 to Subpart I of... - Instructions for Preparation of Evaluation Report of Self-Help Technical Assistance Grants

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... to Subpart I of Part 1944—Instructions for Preparation of Evaluation Report of Self-Help Technical... 7 Agriculture 13 2014-01-01 2013-01-01 true Instructions for Preparation of Evaluation Report of Self-Help Technical Assistance Grants B Exhibit B-1 to Subpart I of Part 1944 Agriculture Regulations...

  14. 7 CFR Exhibit B-1 to Subpart I of... - Instructions for Preparation of Evaluation Report of Self-Help Technical Assistance Grants

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... to Subpart I of Part 1944—Instructions for Preparation of Evaluation Report of Self-Help Technical... 7 Agriculture 13 2012-01-01 2012-01-01 false Instructions for Preparation of Evaluation Report of Self-Help Technical Assistance Grants B Exhibit B-1 to Subpart I of Part 1944 Agriculture Regulations...

  15. Integrated Test and Evaluation Flight Test 3 Flight Test Plan

    NASA Technical Reports Server (NTRS)

    Marston, Michael Lawrence

    2015-01-01

    The desire and ability to fly Unmanned Aircraft Systems (UAS) in the National Airspace System (NAS) is of increasing urgency. The application of unmanned aircraft to perform national security, defense, scientific, and emergency management are driving the critical need for less restrictive access by UAS to the NAS. UAS represent a new capability that will provide a variety of services in the government (public) and commercial (civil) aviation sectors. The growth of this potential industry has not yet been realized due to the lack of a common understanding of what is required to safely operate UAS in the NAS. NASA's UAS Integration into the NAS Project is conducting research in the areas of Separation Assurance/Sense and Avoid Interoperability, Human Systems Integration (HSI), and Communication to support reducing the barriers of UAS access to the NAS. This research is broken into two research themes namely, UAS Integration and Test Infrastructure. UAS Integration focuses on airspace integration procedures and performance standards to enable UAS integration in the air transportation system, covering Sense and Avoid (SAA) performance standards, command and control performance standards, and human systems integration. The focus of Test Infrastructure is to enable development and validation of airspace integration procedures and performance standards, including the integrated test and evaluation. In support of the integrated test and evaluation efforts, the Project will develop an adaptable, scalable, and schedulable relevant test environment capable of evaluating concepts and technologies for unmanned aircraft systems to safely operate in the NAS. To accomplish this task, the Project will conduct a series of Human-in-the-Loop and Flight Test activities that integrate key concepts, technologies and/or procedures in a relevant air traffic environment. Each of the integrated events will build on the technical achievements, fidelity and complexity of the previous tests and technical simulations, resulting in research findings that support the development of regulations governing the access of UAS into the NAS.

  16. UAS Integration in the NAS Project: Integrated Test and Evaluation (IT&E) Flight Test 3. Revision E

    NASA Technical Reports Server (NTRS)

    Marston, Michael

    2015-01-01

    The desire and ability to fly Unmanned Aircraft Systems (UAS) in the National Airspace System (NAS) is of increasing urgency. The application of unmanned aircraft to perform national security, defense, scientific, and emergency management are driving the critical need for less restrictive access by UAS to the NAS. UAS represent a new capability that will provide a variety of services in the government (public) and commercial (civil) aviation sectors. The growth of this potential industry has not yet been realized due to the lack of a common understanding of what is required to safely operate UAS in the NAS. NASA's UAS Integration into the NAS Project is conducting research in the areas of Separation Assurance/Sense and Avoid Interoperability, Human Systems Integration (HSI), and Communication to support reducing the barriers of UAS access to the NAS. This research is broken into two research themes namely, UAS Integration and Test Infrastructure. UAS Integration focuses on airspace integration procedures and performance standards to enable UAS integration in the air transportation system, covering Sense and Avoid (SAA) performance standards, command and control performance standards, and human systems integration. The focus of Test Infrastructure is to enable development and validation of airspace integration procedures and performance standards, including the integrated test and evaluation. In support of the integrated test and evaluation efforts, the Project will develop an adaptable, scalable, and schedulable relevant test environment capable of evaluating concepts and technologies for unmanned aircraft systems to safely operate in the NAS. To accomplish this task, the Project will conduct a series of Human-in-the-Loop and Flight Test activities that integrate key concepts, technologies and/or procedures in a relevant air traffic environment. Each of the integrated events will build on the technical achievements, fidelity and complexity of the previous tests and technical simulations, resulting in research findings that support the development of regulations governing the access of UAS into the NAS.

  17. Economical and technical efficiencies evaluation of full scale piggery wastewater treatment BNR plants.

    PubMed

    Oa, S W; Choi, E; Kim, S W; Kwon, K H; Min, K S

    2009-01-01

    A method evaluating the economic efficiency of piggery waste treatment plant based on kinetics for nitrogen removal performances is executed in this study and five full scale plants were evaluated, monitored intensively during one year under steady-state conditions. The performance data from those surveyed plants were recalculated by first-order kinetic equation instead of the Monod's equation, and the nitrogen removal kinetics related with COD/TKN ratios. Two plants adapting two extreme strategies for pre treatment, 'excess phase separation', and 'minimum phase separation', were evaluated by the assessment of life cycle cost (LCC). Although the compared two plants use an opposite strategy to each other, similar evaluation results are deduced by nitrogen removal efficiencies and operational and construction costs. But the proportions of constituent elements are as different as two opposite strategies, so electrical and construction costs are inversely proportional to chemical costs and operational costs respectively.

  18. Evaluation of Inter-Mountain Labs infrasound sensors : July 2007.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hart, Darren M.

    2007-10-01

    Sandia National Laboratories has tested and evaluated three Inter Mountain Labs infrasound sensors. The test results included in this report were in response to static and tonal-dynamic input signals. Most test methodologies used were based on IEEE Standards 1057 for Digitizing Waveform Recorders and 1241 for Analog to Digital Converters; others were designed by Sandia specifically for infrasound application evaluation and for supplementary criteria not addressed in the IEEE standards. The objective of this work was to evaluate the overall technical performance of the Inter Mountain Labs (IML) infrasound sensor model SS. The results of this evaluation were only comparedmore » to relevant noise models; due to a lack of manufactures documentation notes on the sensors under test prior to testing. The tests selected for this system were chosen to demonstrate different performance aspects of the components under test.« less

  19. Technical aspects of pediatric epilepsy surgery: Report of a multicenter, multinational web-based survey by the ILAE Task Force on Pediatric Epilepsy Surgery.

    PubMed

    Cukiert, Arthur; Rydenhag, Bertil; Harkness, William; Cross, J Helen; Gaillard, William D

    2016-02-01

    Surgical techniques may vary extensively between centers. We report on a web-based survey aimed at evaluating the current technical approaches in different centers around the world performing epilepsy surgery in children. The intention of the survey was to establish technical standards. A request was made to 88 centers to complete a web-based survey comprising 51 questions. There were 14 questions related to general issues, 13 questions investigating the different technical aspects for children undergoing epilepsy surgery, and 24 questions investigating surgical strategies in pediatric epilepsy surgery. Fifty-two centers covering a wide geographic representation completed the questionnaire. The median number of resective procedures per center per year was 47. Some important technical practices appeared (>80% of the responses) such as the use of prophylactic antibiotics (98%), the use of high-speed drills for bone opening (88%), nonresorbable material for bone flap closure (85%), head fixation (90%), use of the surgical microscope (100%), and of free bone flaps. Other questions, such as the use of drains, electrocorticography (ECoG) and preoperative withdrawal of valproate, led to mixed, inconclusive results. Complications were noted in 3.8% of the patients submitted to cortical resection, 9.9% hemispheric surgery, 5% callosotomy, 1.8% depth electrode implantation, 5.9% subdural grids implantation, 11.9% hypothalamic hamartoma resection, 0.9% vagus nerve stimulation (VNS), and 0.5% deep brain stimulation. There were no major differences across regions or countries in any of the subitems above. The present data offer the first overview of the technical aspects of pediatric epilepsy surgery worldwide. Surprisingly, there seem to be more similarities than differences. That aside many of the evaluated issues should be examined by adequately designed multicenter randomized controlled trials (RCTs). Further knowledge on these technical issues might lead to increased standardization and lower costs in the future, as well as definitive practice guidelines. Wiley Periodicals, Inc. © 2016 International League Against Epilepsy.

  20. Evaluation of a System of Electronic Documentation for the Nursing Process

    PubMed Central

    de Oliveira, Neurilene Batista; Peres, Heloisa Helena Ciqueto

    2012-01-01

    The objective of this study is to evaluate the functional performance and the technical quality of an electronic documentation system designed to document the data of the Nursing Process. The Model of Quality will be the one established by the ISO/IEC 25010. Such research will allow the spreading of the knowledge of an emerging area, thus adding a further initiative to the growing efforts made in the information technology area for health and nursing. PMID:24199110

  1. Analysis of space systems study for the space disposal of nuclear waste. Study report, volume 1: Executive summary

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Space systems concepts were identified and defined and evaluated as to their performance, risks, and technical viability in order to select the most attractive approach for disposal of high level nuclear wastes in space. Major study areas discussed include: (1) mission and operations analysis; (2) waste payload systems; (3) flight support system; (4) launch site systems; (5) launch vehicle systems; (6) orbit transfer system; (7) space disposal destinations; and (8) systems integration and evaluation.

  2. Conceptual design study of a V/STOL lift fan commercial short haul transport

    NASA Technical Reports Server (NTRS)

    Knight, R. G.; Powell, W. V., Jr.; Prizlow, J. A.

    1973-01-01

    Conceptual designs of V/STOL lift fan commercial short haul transport aircraft for the 1980-85 time period were studied to determine their technical and economic feasibility. The engine concepts included both integral and remote fans. The scope of the study included definition of the hover control concept for each propulsion system, aircraft design, mass properties, cruise performance, noise and ride qualities evaluation. Economic evaluation was also studied on the basis of direct-operating costs and route structure.

  3. Conceptual design of a V/STOL lift fan commercial short haul transport

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Conceptual designs of V/STOL lift-fan commercial short-haul transport aircraft for the 1980-85 time period were studied to determine their technical and economic feasibility. Engine concepts studied included both integral remote fans. The scope of the study included definition of the hover control concept for each propulsion system, aircraft design, aircraft mass properties, cruise performance noise, and ride qualities evaluation. Economic evaluation was also studied on a basis of direct operating cost and route structure.

  4. Systematic review and meta-analysis of the role of mental training in the acquisition of technical skills in surgery.

    PubMed

    Rao, Ahsan; Tait, Ian; Alijani, Afshin

    2015-09-01

    Mental training is rehearsal of mental imagery without physically performing the task. The aim of the study was to perform systematic review and meta-analysis on all the available data to evaluate the role of mental training in the acquisition of surgical technical skills. The following search databases were used: EMBASE, MEDLINE, Web of Science, Clinicaltrials.gov.uk, SIGN guidelines, NICE guidelines, and Cochrane review register. Meta-analysis was performed using Revman 5.2 statistical software. There were a total of 9 randomized controlled trials with 474 participants, of which 189 participants received mental training. Five randomized controlled trials concluded positive impact of mental training. Mental training group did not show any significant improvement in overall performance of the task carried in each study (P = .06). Mental training can be used as an important supplementary tool in learning surgical skills when run in parallel with physical training and applied to trainees with some experience of the skill. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Engineering analysis activities in support of susquehanna unit 1 startup testing and cycle 1 operations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, G.D.; Kukielka, C.A.; Olson, L.M.

    The engineering analysis group is responsible for all nuclear plant systems analysis and reactor analysis activities, excluding fuel management analysis, at Pennsylvania Power and Light Company. These activities include making pretest and posttest predictions of startup tests; analyzing unplanned or unexpected transient events; providing technical training to plant personnel; assisting in the development of emergency drill scenarios; providing engineering evaluations to support design and technical specification changes, and evaluating, assessing, and resolving a number of license conditions. Many of these activities have required the direct use of RETRAN models. Two RETRAN analyses that were completed to support plant operations -more » a pretest analysis of the turbine trip startup test, and a posttest analysis of the loss of startup transformer event - are investigated. For each case, RETRAN results are compared with available plant data and comparisons are drawn on the acceptability of the performance of the plant systems.« less

  6. The Future of the Space Age or how to Evaluate Innovative Ideas

    NASA Astrophysics Data System (ADS)

    Vollerthun, A.; Fricke, E.

    2002-05-01

    Based on an initiative of the German Aerospace Industry Association to foster a more transparent and structured funding of German commercial-oriented space projects a three-phased approach is suggested in this paper, to stepwise improve and evaluate proposed concepts for space-related innovations. The objective of this concept was to develop a transparent, structured, and reproducible process to select the right innovative project in terms of political, economical, and technical objectives for funding by e.g. a governmental agency. A stepwise process and related methods, that cover technical as well as economical aspects (and related sensitivities) are proposed. Based on the special needs and requirements of space industry the proposals are compared to a set of predefined top level objectives/requirements. Using an initial trades analysis with the criteria company, technology, product, and market, an initial business case is analyzed. The alternative innovative concepts are in the third process step subject to a very detailed analysis. The full economical and technical scale of the projects is evaluated and metrics for e.g. the 'Return on Investment' or 'Break Even Point' are determined, to compare the various innovations. Risks related to time, cost, and quality are considered, when performing sensitivity analysis by varying the most important factors of the project. Before discussing critical aspects of the proposed process, space-related examples will be presented to show how the process could be applied, and how different concepts should be evaluated.

  7. A stochastic dynamic model of a dairy farm to evaluate the technical and economic performance under different scenarios.

    PubMed

    Calsamiglia, S; Astiz, S; Baucells, J; Castillejos, L

    2018-05-23

    Dairy farms need to improve their competitiveness through decisions that are often difficult to evaluate because they are highly dependent on many economic and technical factors. The objective of this project was to develop a stochastic and dynamic mathematical model to simulate the functioning of a dairy farm to evaluate the effect of changes in technical or economic factors on performance and profitability. Submodels were developed for reproduction, feeding, diseases, heifers, environmental factors, facilities, management, and economics. All these submodels were simulated on an animal-by-animal and day-by-day basis. Default values for all variables are provided, but the user can change them. The outcome provides a list of technical and economic indicators essential for the decision-making process. Performance of the program was verified by evaluating the effects and sensitivity analysis of different scenarios in 20 different dairy farms. As an example, a case study of a dairy farm with 300 cows producing 40 L/d and a 12% pregnancy rate (PR) was used. The effect of using a time-fixed artificial insemination (TFAI) protocol in the first insemination at 77 d in milk, with 45 and 40% conception rates for first-lactation and older cows, respectively, and a cost of €13 was explored. During the 5-yr simulation, the TFAI increased PR (12 to 17%) and milk yield per milking cow (39.8 to 41.2 L/d) and reduced days to first AI (93 to 74), days open (143 to 116), and the proportion of problem cows (24.3 to 15.9%). In the TFAI, cows were dried 30 d earlier, resulting in more dry cows, and a smaller difference in milk yield by present cows (35.5 vs 36.0 L/d for control and TFAI, respectively). A longer productive life (2.56 vs. 2.79 yr) with shorter lactations in TFIA resulted in less first-lactation cows (42 vs 36%), 32 more calvings per year, and, therefore, more cases of postpartum diseases. Total (32.5 to 29.9%) and reproductive (10.5 vs 6.8%) culling rates decreased in TFIA. Overall, the net margin was €245 and €309/cow per year in control and TFIA, respectively. The net margin of applying TFAI decreased as PR of the farm increased, with limited benefit of TFAI at a PR of 30%. The model provides a powerful web-based tool to explore the short- and medium-term consequences of technical and economic decisions on the economic sustainability of dairy farms. © 2018, The Authors. Published by the Federation of Animal Science Societies and Elsevier Inc. on behalf of the American Dairy Science Association®. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/).

  8. Evaluating the effectiveness of case method instruction in technical communication

    NASA Technical Reports Server (NTRS)

    Feinberg, S. G.

    1981-01-01

    The effectiveness of the case method as an instructional technique in improving technical writing was evaluated. The development of a self-report instrument that attempts to measure changes in attitude toward technical communication and the presentation results change are the purpose of this paper. Standards for developing a case set forth by Goldstein and Couture, were used to design an evaluation instrument to measure the effect instruction on student attitude toward technical communication. This self-report instrument is based on model developed and tested by Daly and Miller who studied writer attitude and apprehension toward writing. It was the most important objective of any evaluation is to provide information for improving the program.

  9. 48 CFR 215.404-71-2 - Performance risk.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...—the technical uncertainties of performance. (2) Management/cost control—the degree of management... Technical (1) (2) N/A N/A 22 Management/Cost Control (1) (2) N/A N/A 23 Performance Risk (Composite) N/A (3...(percent) Assignedvalue (percent) Weightedvalue (percent) Technical 60 5.0 3.0 Management/Cost Control 40 4...

  10. Transcatheter Coil Embolization of Splenic Artery Aneurysm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamamoto, Satoshi, E-mail: s-yama@hyo-med.ac.jp; Hirota, Shozo; Maeda, Hiroaki

    2008-05-15

    The purpose of this study was to evaluate clinical results and technical problems of transcatheter coil embolization for splenic artery aneurysm. Subjects were 16 patients (8 men, 8 women; age range, 40-80 years) who underwent transcatheter embolization for splenic artery aneurysm (14 true aneurysms, 2 false aneurysms) at one of our hospitals during the period January 1997 through July 2005. Two aneurysms (12.5%) were diagnosed at the time of rupture. Multiple splenic aneurysms were found in seven patients. Aneurysms were classified by site as proximal (or strictly ostial) (n = 3), middle (n = 3), or hilar (n = 10).more » The indication for transcatheter arterial embolization was a false or true aneurysm 20 mm in diameter. Embolic materials were fibered coils and interlocking detachable coils. Embolization was performed by the isolation technique, the packing technique, or both. Technically, all aneurysms were devascularized without severe complications. Embolized aneurysms were 6-40 mm in diameter (mean, 25 mm). Overall, the primary technical success rate was 88% (14 of 16 patients). In the remaining 2 patients (12.5%), partial recanalization occurred, and re-embolization was performed. The secondary technical success rate was 100%. Seven (44%) of the 16 study patients suffered partial splenic infarction. Intrasplenic branching originating from the aneurysm was observed in five patients. We conclude that transcatheter coil embolization should be the initial treatment of choice for splenic artery aneurysm.« less

  11. The impact of active controls technology on the structural integrity of aeronautical vehicles

    NASA Technical Reports Server (NTRS)

    Noll, Thomas E.; Austin, Edward; Donley, Shawn; Graham, George; Harris, Terry; Kaynes, Ian; Lee, Ben; Sparrow, James

    1993-01-01

    The findings of an investigation conducted under the auspices of The Technical Cooperation Program (TTCP) to assess the impact of active controls technology on the structural integrity of aeronautical vehicles and to evaluate the present state-of-the-art for predicting loads caused by a flight-control system modification and the resulting change in the fatigue life of the flight vehicle are summarized. Important points concerning structural technology considerations implicit in applying active controls technology in new aircraft are summarized. These points are well founded and based upon information received from within the aerospace industry and government laboratories, acquired by sponsoring workshops which brought together experts from contributing and interacting technical disciplines, and obtained by conducting a case study to independently assess the state of the technology. The paper concludes that communication between technical disciplines is absolutely essential in the design of future high performance aircraft.

  12. Productivity in using school's resources: A case study of secondary school in Dumai, Riau Indonesia

    NASA Astrophysics Data System (ADS)

    Rozamuri, Arif Murti; Suradi, Nur Riza Mohd

    2015-09-01

    Definition of good school's differs for every individual. The performance of the school's has always been an interesting discussion topic. This situation requires parents to be more selective for choosing the best school's for their child, especially in the efficient management of resources. This study evaluated changes in total productivity, technology, technical efficiency, and scale efficiency among 12 school of Dumai City in Riau Indonesia using DEA Malmquist Index. The inputs include number of teacher's, number of students, and number of classrooms while output is the number of students that passed the national examination. The results show that average efficiency of secondary school in Dumai City from 2011 to 2013 recorded good changes in terms of technical efficiency, pure technical efficiency and scale efficiency. However, technological and total factor productivity change do not show a positive change.

  13. Test and Evaluation of the Navy Technical Information Presentation System (NTIPS) F-14A Field Test Results

    DTIC Science & Technology

    1988-09-01

    Test and Evaluation Report Test and Evaluation of the Navy Technical Information Presentation System (NTIPS) F-14A Field Test Results by .0 Joseph J...PROGRAM PROJECT TASK WORK UNIT Washington, D.C. 20361 ELEMENT NO. NO. NO. ACCESSION NO. OMN 1820 11. TITLE (Include Security Classification) TEST AND...EVALUATION OF THE NAVY TECHNICAL INFORMATION PRESENTATION SYSTEM (NTIPS) F-14A FIELD TEST RESULTS 12. PERSONAL AUTHOR(S) Fuller, Joseph F. (DTRC) Post

  14. NASA Boeing 737 Aircraft Test Results from 1996 Joint Winter Runway Friction Measurement Program

    NASA Technical Reports Server (NTRS)

    Yager, Thomas J.

    1996-01-01

    A description of the joint test program objectives and scope is given together with the performance capability of the NASA Langley B-737 instrumented aircraft. The B-737 test run matrix conducted during the first 8 months of this 5-year program is discussed with a description of the different runway conditions evaluated. Some preliminary test results are discussed concerning the Electronic Recording Decelerometer (ERD) readings and a comparison of B-737 aircraft braking performance for different winter runway conditions. Detailed aircraft parameter time history records, analysis of ground vehicle friction measurements and harmonization with aircraft braking performance, assessment of induced aircraft contaminant drag, and evaluation of the effects of other factors on aircraft/ground vehicle friction performance will be documented in a NASA Technical Report which is being prepared for publication next year.

  15. Evaluation of the Hydrolab HL4 water-quality sonde and sensors

    USGS Publications Warehouse

    Snazelle, Teri T.

    2017-12-18

    The U.S. Geological Survey (USGS) Hydrologic Instrumentation Facility evaluated three Hydrolab HL4 multiparameter water-quality sondes by OTT Hydromet. The sondes were equipped with temperature, conductivity, pH, dissolved oxygen (DO), and turbidity sensors. The sensors were evaluated for compliance with the USGS National Field Manual for the Collection of Water-Quality Data (NFM) criteria for continuous water-quality monitors and to verify the validity of the manufacturer’s technical specifications. The conductivity sensors were evaluated for the accuracy of the specific conductance (SC) values (conductance at 25 degrees Celsius [oC]), that were calculated by using the vendor default method, Hydrolab Fresh. The HL4’s communication protocols and operating temperature range along with accuracy of the water-quality sensors were tested in a controlled laboratory setting May 1–19, 2016. To evaluate the sonde’s performance in a surface-water field application, an HL4 equipped with temperature, conductivity, pH, DO, and turbidity sensors was deployed June 20–July 22, 2016, at USGS water-monitoring site 02492620, Pearl River at National Space Technology Laboratories (NSTL) Station, Mississippi, located near Bay Saint Louis, Mississippi, and compared to the adjacent well-maintained EXO2 site sonde.The three HL4 sondes met the USGS temperature testing criteria and the manufacturer’s technical specifications for temperature based upon the median room temperature difference between the measured and standard temperatures, but two of the three sondes exceeded the allowable difference criteria at the temperature extremes of approximately 5 and 40 ºC. Two sondes met the USGS criteria for SC. One of the sondes failed the criteria for SC when evaluated in a 100,000-microsiemens-per-centimeter (μS/cm) standard at room temperature, and also failed in a 10,000-μS/cm standard at 5, 15, and 40 ºC. All three sondes met the USGS criteria for pH and DO at room temperature, but one sonde exceeded the allowable difference criteria when tested in pH 5.00 buffer and at 40 ºC. The USGS criteria and the technical specifications for turbidity were met by one sonde in standards ranging from 10 to 3,000 nephelometric turbidity units (NTU). A second sonde met the USGS criteria and the technical specifications except in the 3,000-NTU standard, and the third sonde exceeded the USGS calibration criteria in the 10- and 20-NTU standards and the technical specifications in the 20-NTU standard.Results of the field test showed acceptable performance and revealed that differences in data sample processing between sonde manufacturers may result in variances between the reported measurements when comparing one sonde to another. These variances in data would be more pronounced in dynamic site conditions. The lack of a wiper or other sensor-cleaning device on the DO sensor could prove problematic, and could limit the use of the HL4 to profiling applications or at sites with limited biofouling.

  16. Fitness testing of tennis players: How valuable is it?

    PubMed Central

    Fernandez-Fernandez, Jaime; Ulbricht, Alexander; Ferrauti, Alexander

    2014-01-01

    In tennis, sport-specific technical skills are predominant factors, although a complex profile of physical performance factors is also required. The fitness test batteries assist in examining tennis players’ capabilities for performance at different levels in the laboratory as well as in the field, in the junior or elite level. While laboratory tests can be, and are, used to evaluate basic performance characteristics of athletes in most individual sports, in a more specific approach, field-based methods are better suited to the demands of complex intermittent sports like tennis. A regular test battery performed at different periods of the year allows to obtain an individual's performance profile, as well as the ability to prescribe individual training interventions. Thus, the aim of the present review was to describe and evaluate the different physical tests recommended and used by practitioners, sports scientists and institutions (national tennis federations). PMID:24668375

  17. Multicriteria decision-aid method to evaluate the performance of stormwater infiltration systems over the time.

    PubMed

    Moura, P; Barraud, S; Baptista, M B; Malard, F

    2011-01-01

    Nowadays, stormwater infiltration systems are frequently used because of their ability to reduce flows and volumes in downstream sewers, decrease overflows in surface waters and make it possible to recharge groundwater. Moreover, they come in various forms with different uses. Despite these advantages the long term sustainability of these systems is questionable and their real performances have to be assessed taking into account various and sometimes conflicting aspects. To address this problem a decision support system is proposed. It is based on a multicriteria method built to help managers to evaluate the performance of an existing infiltration system at different stages of its lifespan and identify whether it performs correctly or not, according to environmental, socio-economic, technical and sanitary aspects. The paper presents successively: the performance indicators and the way they were built, the multicriteria method to identify if the system works properly and a case study.

  18. How does PET/MR work? Basic physics for physicians.

    PubMed

    Delso, Gaspar; Ter Voert, Edwin; Veit-Haibach, Patrick

    2015-08-01

    The aim of this article is to provide Radiologists and Nuclear Medicine physicians the basic information required to understand how PET/MR scanners work, what are their limitations and how to evaluate their performance. It will cover the operational principles of standalone PET and MR imaging, as well as the technical challenges of creating a hybrid system and how they have been solved in the now commercially available scanners. Guidelines will be provided to interpret the main performance figures of hybrid PET/MR systems.

  19. Science in the Sun: How Science is Performed as a Spatial Practice

    NASA Astrophysics Data System (ADS)

    Kass, Natalie

    This study analyzes how spatial organization impacts science communication at the St. Petersburg Science Festival in Florida. Through map analysis, qualitative interviews, and a close reading of evaluation reports, the author determines that sponsorship, logistics, exhibitor ambience, and map usability and design are the factors most affecting the spatial performance of science. To mitigate their effects, technical communicators can identify these factors and provide the necessary revisions when considering how science is communicated to the public.

  20. DOT/NASA comparative assessment of Brayton engines for guideway vehicles and busses. Volume 2: Analysis and results

    NASA Technical Reports Server (NTRS)

    1975-01-01

    Gas turbine engines were assessed for application to hear duty transportation. A summary of the assumptions, applications, and methods of analysis is included along with a discussion of the approach taken, the technical program flow chart, and weighting criteria used for performance evaluation. The various engines are compared on the bases of weight, performance, emissions and noise, technology status, and growth potential. The results of the engine screening phase and the conceptual design phase are presented.

Top