A facile fluorescent "turn-off" method for sensing paraquat based on pyranine-paraquat interaction
NASA Astrophysics Data System (ADS)
Zhao, Zuzhi; Zhang, Fengwei; Zhang, Zipin
2018-06-01
Development of a technically simple yet effective method for paraquat (PQ) detection is of great importance due to its high clinical and environmental relevance. In this study, we developed a pyranine-based fluorescent "turn-off" method for PQ sensing based on pyranine-PQ interaction. We investigated the dependence of analytical performance of this method on the experimental conditions, such as the ion strength, medium pH, and so on. Under the optimized conditions, the method is sensitive and selective, and could be used for PQ detection in real-world sample. This study essentially provides a readily accessible fluorescent system for PQ sensing which is cheap, robust, and technically simple, and it is envisaged to find more interesting clinical and environmental applications.
Technical aspects of oxygen saving devices.
Brambilla, I; Arlati, S; Chiusa, I; Micallef, E
1990-01-01
Oxygen economizing devices have been extensively studied, both at rest and during muscular exercise, in an attempt to increase the autonomy of a portable oxygen apparatus. The aim of this study is threefold: first, to suggest a simple method to verify in a simple way the technical accuracy of a demand flow oxygen delivery device; second, to suggest how we can monitor in a simple way the clinical efficacy of an economizer; and third, to remember that we can utilize an oxygen saving device to give a better protection than nasal prongs against the worsening of HbO2 desaturation induced by exercise.
Naimi, Ashley I; Cole, Stephen R; Kennedy, Edward H
2017-04-01
Robins' generalized methods (g methods) provide consistent estimates of contrasts (e.g. differences, ratios) of potential outcomes under a less restrictive set of identification conditions than do standard regression methods (e.g. linear, logistic, Cox regression). Uptake of g methods by epidemiologists has been hampered by limitations in understanding both conceptual and technical details. We present a simple worked example that illustrates basic concepts, while minimizing technical complications. © The Author 2016; all rights reserved. Published by Oxford University Press on behalf of the International Epidemiological Association.
Song, Chihong; Lee, Ju Huck; Jun, Sangmi; Chung, Jeong Min; Hyun, Jaekyung; Jung, Hyun Suk
2016-05-01
The preparation of biological specimens using cryofixation techniques ensures excellent visibility of intracellular structures and preserves the antigenic sites of subcellular molecules. Hence, cryofixation is an effective method of preparing samples for analyses using antibodies conjugated to gold nanoparticles that are designed to detect the localization of specific target molecules within cells. However, cryofixation cannot be utilized easily because it requires expensive equipment and skilled technologists, resulting in a high level of expense for researchers. Here, we describe a simple technical approach to cryofixation that uses metal contact quick freezing followed by a modified freeze substitution technique and immuno-gold labeling electron microscopy. Micrograph images of cells prepared using this modified cryofixation method demonstrated its superiority over chemical fixation for high contrast visualization of the morphologies of cellular components and preservation of antigenicity for immuno-gold labeling. This report provides valuable technical information related to the advancement of metal contact quick freezing techniques, which can be used to visualize biomedical events of interest in an easy, simple, and rapid manner.
Monosodium glutamate for simple photometric iron analysis
NASA Astrophysics Data System (ADS)
Prasetyo, E.
2018-01-01
Simple photometric method for iron analysis using monosodium glutamate (MSG) was proposed. The method could be used as an alternative method, which was technically simple, economic, quantitative, readily available, scientifically sound and environmental friendly. Rapid reaction of iron (III) with glutamate in sodium chloride-hydrochloric acid buffer (pH 2) to form red-brown complex was served as a basis in the photometric determination, which obeyed the range of iron (III) concentration 1.6 - 80 µg/ml. This method could be applied to determine iron concentration in soil with satisfactory results (accuracy and precision) compared to other photometric and atomic absorption spectrometry results.
An Inexpensive and Simple Method to Demonstrate Soil Water and Nutrient Flow
ERIC Educational Resources Information Center
Nichols, K. A.; Samson-Liebig, S.
2011-01-01
Soil quality, soil health, and soil sustainability are concepts that are being widely used but are difficult to define and illustrate, especially to a non-technical audience. The objectives of this manuscript were to develop simple and inexpensive methodologies to both qualitatively and quantitatively estimate water infiltration rates (IR),…
Ball, P A; Benzel, E C; Baldwin, N G
1994-04-01
The use of bone plate instrumentation with screw fixation has proved to be a useful adjunctive measure in anterior cervical spine fusion surgery. Proper fitting, positioning, and attachment of this instrumentation have been shown to be frequently suboptimal if done without radiographic guidance. The most commonly used method of radiographic assistance for placement of this instrumentation is fluoroscopy. While this gives satisfactory technical results, it is expensive and time-consuming, and exposes the patient and the operating room personnel to ionizing radiation. The authors present a simple technique to ensure screw placement and plate fitting using Kirschner wires and a single lateral radiograph. This technique saves time, reduces exposure to radiation, and has led to satisfactory results in over 20 operative cases.
78 FR 76748 - Citizen Petition Submission; Technical Amendment
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-19
... process to add a simple and electronic method, ensures clarity in the Agency's regulations, and updates... petitioner of the filing and unique docket number of the petition. (d) An interested person may submit...
Tools for the Classroom? an Examination of Existing Sociometric Methods for Teacher Use
ERIC Educational Resources Information Center
McMullen, Jake A.; Veermans, Koen; Laine, Kaarina
2014-01-01
Despite the recent technical and theoretical advances in the investigation of children's social relations, the inherent complexity of these methods may prevent their easy integration into the classroom. A simple and effective tool can be valuable for teachers who wish to investigate students' social realities in the classroom. Therefore, the…
Aerial sketchmapping for monitoring forest conditions in Southern Brazil
Y. M. Malheiros de Oliveira; M. A. Doetzer Rosot; N. B. da Luz; W. M. Ciesla; E.W. Johnson; R. Rhea; J.F. Jr. Penteado
2006-01-01
Aerial sketchmapping is a simple, low cost remote sensing method used for detection and mapping of forest damage caused by biotic agents (insects, pathogens and other pests) and abiotic agents (wind, fire, storms, hurricane, ice storms) in North America. This method was introduced to Brazil in 2001/2002 via a USDA Forest Service/EMBRAPA technical exchange program,...
ERIC Educational Resources Information Center
Stevens, Olinger; Leigh, Erika
2012-01-01
Scope and Method of Study: The purpose of the study is to use an empirical approach to identify a simple, economical, efficient, and technically adequate performance measure that teachers can use to assess student growth in mathematics. The current study has been designed to expand the body of research for math CBM to further examine technical…
[Rapid detection of caffeine in blood by freeze-out extraction].
Bekhterev, V N; Gavrilova, S N; Kozina, E P; Maslakov, I V
2010-01-01
A new method for the detection of caffeine in blood has been proposed based on the combination of extraction and freezing-out to eliminate the influence of sample matrix. Metrological characteristics of the method are presented. Selectivity of detection is achieved by optimal conditions of analysis by high performance liquid chromatography. The method is technically simple and cost-efficient, it ensures rapid performance of the studies.
Jabbour, Noel; Sidman, James
2011-10-01
There has been an increasing interest in assessment of technical skills in most medical and surgical disciplines. Many of these assessments involve microscopy or endoscopy and are thus amenable to video recording for post hoc review. An ideal skills assessment video would provide the reviewer with a simultaneous view of the examinee's instrument handling and the operative field. Ideally, a reviewer should be blinded to the identity of the examinee and whether the assessment was performed as a pretest or posttest examination, when given in conjunction with an educational intervention. We describe a simple method for reliably creating deidentified, multicamera, time-synced videos, which may be used in technical skills assessments. We pilot tested this method in a pediatric airway endoscopy Objective Assessment of Technical Skills (OSATS). Total video length was compared with the OSATS administration time. Thirty-nine OSATS were administered. There were no errors encountered in time-syncing the videos using this method. Mean duration of OSATS videos was 11 minutes and 20 seconds, which was significantly less than the time needed for an expert to be present at the administration of each 30-minute OSATS (P < 0.001). The described method for creating time-synced, multicamera skills assessment videos is reliable and may be used in endosurgical or microsurgical skills assessments. Compared with live review, post hoc video review using this method can save valuable expert reviewer time. Most importantly, this method allows a reviewer to simultaneously evaluate an examinee's instrument handling and the operative field while being blinded to the examinee's identity and timing of examination administration.
Omran, Esraa; Grandison, Tyrone; Abu Almaati, Shereef
2010-01-01
Healthcare applications that have access control, disclosure management and or privacy enforcement requirements may implement the respective solutions to these issues at the application level or at the database level or in both. Unfortunately, there are technical and non-technical factors that influence what can be done. In this paper we present a flexible, simple and novel approach to seamlessly imbuing current healthcare applications and their supporting infrastructure with security and privacy functionality, while being cognizant of these factors. This approach is called the Chain method. This paper will highlight the smaller design footprint, the increased ease of implementation and use of the Chain method, while demonstrating that it is as powerful and effective as traditional methods.
Best Technical Approach for the Petroleum Quality Analysis (PQA) System
1994-08-01
two test methods for determination of water content in a fuel. The Karl Fischer titration method (ASTM D 1744) measures for total water, both...difficult to automate. ASTM D 664, "Standard Test Method for Acid Number of Petroleum Products by Potentiometric Titration," is simple to automate...release. distribution unlimnied 13. ABSTRACT (Maximum 2C3 words) Recent U.S. militar-y operations have identified a need for improved methods of fuel and
Application of augmented reality for inferior alveolar nerve block anesthesia: A technical note
2017-01-01
Efforts to apply augmented reality (AR) technology in the medical field include the introduction of AR techniques into dental practice. The present report introduces a simple method of applying AR during an inferior alveolar nerve block, a procedure commonly performed in dental clinics. PMID:28879340
Application of augmented reality for inferior alveolar nerve block anesthesia: A technical note.
Won, Yu-Jin; Kang, Sang-Hoon
2017-06-01
Efforts to apply augmented reality (AR) technology in the medical field include the introduction of AR techniques into dental practice. The present report introduces a simple method of applying AR during an inferior alveolar nerve block, a procedure commonly performed in dental clinics.
1979-05-01
and social problems, does not lend itself to a single or simple solution. This is why we must all be involved. For this reason we. believe that...of admission to decisionmaking. At times the implications of this relatively simple premise are not minor. Many people beginning community...involvement programs have found it extremely difficult to locate technical people able to translate technical reports into simple , every- day English. There
Dehydration Polymerization for Poly(hetero)arene Conjugated Polymers.
Mirabal, Rafael A; Vanderzwet, Luke; Abuadas, Sara; Emmett, Michael R; Schipper, Derek
2018-02-18
The lack of scalable and sustainable methods to prepare conjugated polymers belies their importance in many enabling technologies. Accessing high-performance poly(hetero)arene conjugated polymers by dehydration has remained an unsolved problem in synthetic chemistry and has historically required transitional-metal coupling reactions. Herein, we report a dehydration method that allows access to conjugated heterocyclic materials. By using the technique, we have prepared a series of small molecules and polymers. The reaction avoids using transition metals, proceeds at room temperature, the only required reactant is a simple base and water is the sole by-product. The dehydration reaction is technically simple and provides a sustainable and straightforward method to prepare conjugated heteroarene motifs. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Xu, Yan; Wu, Qian; Shimatani, Yuji; Yamaguchi, Koji
2015-10-07
Due to the lack of regeneration methods, the reusability of nanofluidic chips is a significant technical challenge impeding the efficient and economic promotion of both fundamental research and practical applications on nanofluidics. Herein, a simple method for the total regeneration of glass nanofluidic chips was described. The method consists of sequential thermal treatment with six well-designed steps, which correspond to four sequential thermal and thermochemical decomposition processes, namely, dehydration, high-temperature redox chemical reaction, high-temperature gasification, and cooling. The method enabled the total regeneration of typical 'dead' glass nanofluidic chips by eliminating physically clogged nanoparticles in the nanochannels, removing chemically reacted organic matter on the glass surface and regenerating permanent functional surfaces of dissimilar materials localized in the nanochannels. The method provides a technical solution to significantly improve the reusability of glass nanofluidic chips and will be useful for the promotion and acceleration of research and applications on nanofluidics.
[Artistic anatomy of the nose: proposals for a simplified project of rhinoplasty].
Polselli, R; Saban, Y
2007-01-01
The authors developed an original and simple method of evaluation of the aesthetic lines of the nose adapted to the harmony of the face. Initially based on their experience, the authors propose an evaluation of the nose in 2 stages and 5 sequencies based on the construction of single circuit lines according to various incidences. They checked thereafter the validity of this method on the operative project and on the appreciation of the results of the rhinoplasties. Controlled on several types of faces, the method suggested by the authors proved to be reliable, simple, reproducible. The authors proposed a method of evaluation of the aesthetic lines of the nose integrated to the harmony of the face. This method relies on the construction, in 5 stages, of single circuit lines not requiring any particular material. The artistic method of evaluation of the nose proposed by the authors is very simple. Rapid and immediately usable, it makes it possible to schedule a rhinoplasty in a few minutes. The evaluation of the aesthetic results of the rhinoplasties is also very simple and reproducible. It has moreover the merit to propose a model of teaching making it possible to the rhinoplastician to criticize his results and thus to progress in its technical training and its operational indications.
Suprapubic cystostomy using optical urethrotome in female patients.
Sawant, Ajit Somaji; Patwardhan, Sujata K; Attar, Mohammad Ismail; Varma, Radheshyam; Bansal, Ujjwal
2009-08-01
In many female patients for lower urinary tract reconstructive procedures, a suprapubic cystostomy along with perurethral catheter is required for urinary diversion. We describe a new and simple method of intraoperative suprapubic catheter placement using optical urethrotome wherein distension of bladder is not required. A total of 26 patients underwent suprapubic catheter placement intraoperatively with the aid of Sachse' optical urethrotome and its outer sheath from January 2005 to May 2008. A 16F Foley catheter could be successfully placed suprapubically in all patients with this method. There were no complications like injury to intraabdominal viscera, retropubic hematoma, hematuria, or catheter dislodgement. We describe a new method of intraoperative suprapubic catheter placement in female patients that is minimally invasive, technically safe, simple, and effective, and does not require bladder distension.
The NIST Simple Guide for Evaluating and Expressing Measurement Uncertainty
NASA Astrophysics Data System (ADS)
Possolo, Antonio
2016-11-01
NIST has recently published guidance on the evaluation and expression of the uncertainty of NIST measurement results [1, 2], supplementing but not replacing B. N. Taylor and C. E. Kuyatt's (1994) Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results (NIST Technical Note 1297) [3], which tracks closely the Guide to the expression of uncertainty in measurement (GUM) [4], originally published in 1995 by the Joint Committee for Guides in Metrology of the International Bureau of Weights and Measures (BIPM). The scope of this Simple Guide, however, is much broader than the scope of both NIST Technical Note 1297 and the GUM, because it attempts to address several of the uncertainty evaluation challenges that have arisen at NIST since the 1990s, for example to include molecular biology, greenhouse gases and climate science measurements, and forensic science. The Simple Guide also expands the scope of those two other guidance documents by recognizing observation equations (that is, statistical models) as bona fide measurement models. These models are indispensable to reduce data from interlaboratory studies, to combine measurement results for the same measurand obtained by different methods, and to characterize the uncertainty of calibration and analysis functions used in the measurement of force, temperature, or composition of gas mixtures. This presentation reviews the salient aspects of the Simple Guide, illustrates the use of models and methods for uncertainty evaluation not contemplated in the GUM, and also demonstrates the NIST Uncertainty Machine [5] and the NIST Consensus Builder, which are web-based applications accessible worldwide that facilitate evaluations of measurement uncertainty and the characterization of consensus values in interlaboratory studies.
ERIC Educational Resources Information Center
Bozkurt, Sinan
2018-01-01
There are several different methods of learning motor skills, like traditional (linear) and differential (nonlinear) learning training. The traditional motor learning approach proposes that learners improve a skill just by repeating it. According to the teaching principles, exercises are selected along continua from easy to hard and from simple to…
Subsonic aircraft: Evolution and the matching of size to performance
NASA Technical Reports Server (NTRS)
Loftin, L. K., Jr.
1980-01-01
Methods for estimating the approximate size, weight, and power of aircraft intended to meet specified performance requirements are presented for both jet-powered and propeller-driven aircraft. The methods are simple and require only the use of a pocket computer for rapid application to specific sizing problems. Application of the methods is illustrated by means of sizing studies of a series of jet-powered and propeller-driven aircraft with varying design constraints. Some aspects of the technical evolution of the airplane from 1918 to the present are also briefly discussed.
Esophageal dilation with metal olives under fiberoptic endoscopic control: a new technic.
Mangla, J C; Kothari, T
1980-03-01
Three patients with marked strictures (less than 20 Fr.) of the esophagus are described. It was very difficult to institute any simple program of dilation because mercury-filled Maloney bougies will buckle and rigid endoscopy with dilation carries a great risk of perforation. Using the conventional methods such as Eder-Puestow dilation results in significant waste of time, money and fluoroscopic help. A new technic is described whereby a successful dilation was carried out under direct visual control by endoscopic dilation of the esophagus with Eder-Puestow dilators. Since all these patients require esophagoscopy, the dilation procedure can be done in the same sitting.
Application of da Vinci(®) Robot in simple or radical hysterectomy: Tips and tricks.
Iavazzo, Christos; Gkegkes, Ioannis D
2016-01-01
The first robotic simple hysterectomy was performed more than 10 years ago. These days, robotic-assisted hysterectomy is accepted as an alternative surgical approach and is applied both in benign and malignant surgical entities. The two important points that should be taken into account to optimize postoperative outcomes in the early period of a surgeon's training are how to achieve optimal oncological and functional results. Overcoming any technical challenge, as with any innovative surgical method, leads to an improved surgical operation timewise as well as for patients' safety. The standardization of the technique and recognition of critical anatomical landmarks are essential for optimal oncological and clinical outcomes on both simple and radical robotic-assisted hysterectomy. Based on our experience, our intention is to present user-friendly tips and tricks to optimize the application of a da Vinci® robot in simple or radical hysterectomies.
Widely tunable laser frequency offset lock with 30 GHz range and 5 THz offset.
Biesheuvel, J; Noom, D W E; Salumbides, E J; Sheridan, K T; Ubachs, W; Koelemeij, J C J
2013-06-17
We demonstrate a simple and versatile method to greatly extend the tuning range of optical frequency shifting devices, such as acousto-optic modulators (AOMs). We use this method to stabilize the frequency of a tunable narrow-band continuous-wave (CW) laser to a transmission maximum of an external Fabry-Perot interferometer (FPI) with a tunable frequency offset. This is achieved through a servo loop which contains an in-loop AOM for simple radiofrequency (RF) tuning of the optical frequency over the full 30 GHz mode-hop-free tuning range of the CW laser. By stabilizing the length of the FPI to a stabilized helium-neon (HeNe) laser (at 5 THz offset from the tunable laser) we simultaneously transfer the ~ 1 MHz absolute frequency stability of the HeNe laser to the entire 30 GHz range of the tunable laser. Thus, our method allows simple, wide-range, fast and reproducible optical frequency tuning and absolute optical frequency measurements through RF electronics, which is here demonstrated by repeatedly recording a 27-GHz-wide molecular iodine spectrum at scan rates up to 500 MHz/s. General technical aspects that determine the performance of the method are discussed in detail.
NASA Astrophysics Data System (ADS)
Chen, Jing-Chao; Zhou, Yu; Wang, Xi
2018-02-01
Technical trading rules have been widely used by practitioners in financial markets for a long time. The profitability remains controversial and few consider the stationarity of technical indicators used in trading rules. We convert MA, KDJ and Bollinger bands into stationary processes and investigate the profitability of these trading rules by using 3 high-frequency data(15s,30s and 60s) of CSI300 Stock Index Futures from January 4th 2012 to December 31st 2016. Several performance and risk measures are adopted to assess the practical value of all trading rules directly while ADF-test is used to verify the stationarity and SPA test to check whether trading rules perform well due to intrinsic superiority or pure luck. The results show that there are several significant combinations of parameters for each indicator when transaction costs are not taken into consideration. Once transaction costs are included, trading profits will be eliminated completely. We also propose a method to reduce the risk of technical trading rules.
Force Eruption of Mandibular Second Incisor in an 11- Year Old Boy: A Technical Report
Sobhnamayan, F; Moazami, F; Hamedi, S; Meshki, R
2013-01-01
There is a great challenge in the treatment of deeply fractured and un-restorable teeth among dentists. Orthodontic force eruption is a method of treatment for these teeth to preserve natural root system and periodontal structures. This technical report is a new modification of this procedure presented in an 11- year old boy with deeply fractured left second mandibular incisor. The fractured teeth were treated with root canal therapy and a file #80 was modified to become a hook cemented into the fractured tooth. Anterior teeth were splinted and used as anchorage to help the root extrusion. 1-year follow up of the tooth showed the convenience of the treatment. This simple and low-cost method can be an acceptable alternative to the current high cost techniques, achieving the same results. PMID:24724126
TRSkit: A Simple Digital Library Toolkit
NASA Technical Reports Server (NTRS)
Nelson, Michael L.; Esler, Sandra L.
1997-01-01
This paper introduces TRSkit, a simple and effective toolkit for building digital libraries on the World Wide Web. The toolkit was developed for the creation of the Langley Technical Report Server and the NASA Technical Report Server, but is applicable to most simple distribution paradigms. TRSkit contains a handful of freely available software components designed to be run under the UNIX operating system and served via the World Wide Web. The intended customer is the person that must continuously and synchronously distribute anywhere from 100 - 100,000's of information units and does not have extensive resources to devote to the problem.
Brief Lags in Interrupted Sequential Performance: Evaluating a Model and Model Evaluation Method
2015-01-05
rehearsal mechanism in the model. To evaluate the model we developed a simple new goodness-of-fit test based on analysis of variance that offers an...repeated step). Sequen- tial constraints are common in medicine, equipment maintenance, computer programming and technical support, data analysis ...legal analysis , accounting, and many other home and workplace environ- ments. Sequential constraints also play a role in such basic cognitive processes
Optimal Post-Operative Immobilisation for Supracondylar Humeral Fractures.
Azzolin, Lucas; Angelliaume, Audrey; Harper, Luke; Lalioui, Abdelfettah; Delgove, Anaïs; Lefèvre, Yan
2018-05-25
Supracondylar humeral fractures (SCHFs) are very common in paediatric patients. In France, percutaneous fixation with two lateral-entry pins is widely used after successful closed reduction. Post-operative immobilisation is typically with a long arm cast combined with a tubular-bandage sling that immobilises the shoulder and holds the arm in adduction and internal rotation to prevent external rotation of the shoulder, which might cause secondary displacement. The objective of this study was to compare this standard immobilisation technique to a posterior plaster splint with a simple sling. Secondary displacement is not more common with a posterior plaster splint and sling than with a long arm cast. 100 patients with extension Gartland type III SCHFs managed by closed reduction and percutaneous fixation with two lateral-entry pins between December 2011 and December 2015 were assessed retrospectively. Post-operative immobilisation was with a posterior plaster splint and a simple sling worn for 4 weeks. Radiographs were obtained on days 1, 45, and 90. Secondary displacement occurred in 8% of patients. No patient required revision surgery. The secondary displacement rate was comparable to earlier reports. Of the 8 secondary displacements, 5 were ascribable to technical errors. The remaining 3 were not caused by rotation of the arm and would probably not have been prevented by using the tubular-bandage sling. A posterior plaster splint combined with a simple sling is a simple and effective immobilisation method for SCHFs provided internal fixation is technically optimal. IV, retrospective observational study. Copyright © 2018. Published by Elsevier Masson SAS.
Armour, John A. L.; Palla, Raquel; Zeeuwen, Patrick L. J. M.; den Heijer, Martin; Schalkwijk, Joost; Hollox, Edward J.
2007-01-01
Recent work has demonstrated an unexpected prevalence of copy number variation in the human genome, and has highlighted the part this variation may play in predisposition to common phenotypes. Some important genes vary in number over a high range (e.g. DEFB4, which commonly varies between two and seven copies), and have posed formidable technical challenges for accurate copy number typing, so that there are no simple, cheap, high-throughput approaches suitable for large-scale screening. We have developed a simple comparative PCR method based on dispersed repeat sequences, using a single pair of precisely designed primers to amplify products simultaneously from both test and reference loci, which are subsequently distinguished and quantified via internal sequence differences. We have validated the method for the measurement of copy number at DEFB4 by comparison of results from >800 DNA samples with copy number measurements by MAPH/REDVR, MLPA and array-CGH. The new Paralogue Ratio Test (PRT) method can require as little as 10 ng genomic DNA, appears to be comparable in accuracy to the other methods, and for the first time provides a rapid, simple and inexpensive method for copy number analysis, suitable for application to typing thousands of samples in large case-control association studies. PMID:17175532
NASA Astrophysics Data System (ADS)
Jalba, C. K.; Muminovic, A.; Epple, S.; Barz, C.; Nasui, V.
2017-05-01
With increasing automation, many work processes become more and more complex. Most technical products can no longer be developed and manufactured by a single department. They are often the product of different divisions and require cooperation from different specialist areas. For example, in the Western world, a simple coffee maker is no longer so much in demand. If the buyer has the possibility to choose between a simple coffee maker and a coffee machine with very complex functions, the choice will probably fall to the more complex variant. Technical progress also applies to other technical products, such as grippers and manipulators. In this paper, it is shown how grasping processes can be redefined and developed with interdisciplinary technical approaches. Both conventional and latest developments in mechanical engineering, production technology, mechatronics and sensor technology will be considered.
An Efficient Method for Hair Containment During Head and Neck Surgery.
Zingaretti, Nicola; De Biasio, Fabrizio; Riccio, Michele; Marchesi, Andrea; Parodi, Pier Camillo
2017-11-01
The authors present a simple technique for operations around hair-bearing areas such as during a rhytidectomy. Hair surrounding the surgical field is twisted into bundles and clipped with duckbill clips. The authors repeat the procedure for each strand of hair. Between 5 and 7 duckbill clips may be required per surgery.The clippers are faster, easily applicable, and well performing. They can be used with different hair lengths, and they do not require any additional trimming or shaving; clips also keep the hair firmly in place, and they do not loosen up in the process.This technical note explains a very simple, economical, and less time-consuming method to control hair located around the surgical site. It may be applied to all procedures within the field of the hair-bearing scalp, including craniofacial and maxillofacial surgery.
A modular docking mechanism for in-orbit assembly and spacecraft servicing
NASA Technical Reports Server (NTRS)
Gampe, F.; Priesett, K.; Bentall, R. H.
1985-01-01
A Docking Mechanism concept is described which is suitable for use with autonomous docking systems. The central feature of using simple cylindrical handles on one side and a type of prism seating on the other is offered as a practical method of achieving a standardized structural interface without freezing continued development of the latches, either technically or commercially. The main emphasis in docking mechanism concepts is in two directions: (1) a very simple docking mechanism, involving mainly the latch mechanism to achieve a structural link; and (2) a sophisticated Docking Mechanism, where the latch mechanism is designed for nonrigid spacecraft and the achievement of very low dynamic interactions between spacecraft during the docking process.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Griffiths, Grant; Keegan, E.; Young, E.
Physical characterization is one of the most broad and important categories of techniques to apply in a nuclear forensic examination. Physical characterization techniques vary from simple weighing and dimensional measurements to complex sample preparation and scanning electron microscopy-electron backscatter diffraction analysis. This paper reports on the physical characterization conducted by several international laboratories participating in the fourth Collaborative Materials Exercise, organized by the Nuclear Forensics International Technical Working Group. Methods include a range of physical measurements, microscopy-based observations, and profilometry. In conclusion, the value of these results for addressing key investigative questions concerning two uranium dioxide pellets and a uraniummore » dioxide powder is discussed.« less
Griffiths, Grant; Keegan, E.; Young, E.; ...
2018-01-06
Physical characterization is one of the most broad and important categories of techniques to apply in a nuclear forensic examination. Physical characterization techniques vary from simple weighing and dimensional measurements to complex sample preparation and scanning electron microscopy-electron backscatter diffraction analysis. This paper reports on the physical characterization conducted by several international laboratories participating in the fourth Collaborative Materials Exercise, organized by the Nuclear Forensics International Technical Working Group. Methods include a range of physical measurements, microscopy-based observations, and profilometry. In conclusion, the value of these results for addressing key investigative questions concerning two uranium dioxide pellets and a uraniummore » dioxide powder is discussed.« less
Intraluminal radiation for esophageal cancer: a Howard University technique.
Moorthy, C R; Nibhanupudy, J R; Ashayeri, E; Goldson, A L; Espinoza, M C; Nidiry, J J; Warner, O G; Roux, V J
1982-03-01
The objective of radiotherapeutic management in esophageal cancer is to accomplish maximum tumor sterilization with minimal normal tissue damage. This sincere effort is most often countered by the differential in tumor dose response vs normal tissue tolerance. Intraluminal isotope radiation, with its inherent advantage of rapid dose falloff, spares the lungs, the spinal cord, and other vital structures, yet yields adequately high doses to esophageal tumor. Though in existence since the turn of the century, the method of intracavitary radium bougie application dropped out of favor due to technical difficulties imposed by the size of the radium source and radiation exposure to the personnel involved. The authors describe a simple "iridium 192 afterloading intraluminal technique" that eliminates technical problems and reduces radiation exposure considerably.
Knowledge-based graphical interfaces for presenting technical information
NASA Technical Reports Server (NTRS)
Feiner, Steven
1988-01-01
Designing effective presentations of technical information is extremely difficult and time-consuming. Moreover, the combination of increasing task complexity and declining job skills makes the need for high-quality technical presentations especially urgent. We believe that this need can ultimately be met through the development of knowledge-based graphical interfaces that can design and present technical information. Since much material is most naturally communicated through pictures, our work has stressed the importance of well-designed graphics, concentrating on generating pictures and laying out displays containing them. We describe APEX, a testbed picture generation system that creates sequences of pictures that depict the performance of simple actions in a world of 3D objects. Our system supports rules for determining automatically the objects to be shown in a picture, the style and level of detail with which they should be rendered, the method by which the action itself should be indicated, and the picture's camera specification. We then describe work on GRIDS, an experimental display layout system that addresses some of the problems in designing displays containing these pictures, determining the position and size of the material to be presented.
Innovative electrochemical approach for an early detection of microRNAs.
Lusi, E A; Passamano, M; Guarascio, P; Scarpa, A; Schiavo, L
2009-04-01
The recent findings of circulating cell-free tissue specific microRNAs in the systemic circulation and the potential of their use as specific markers of disease highlight the need to make microRNAs testing a routine part of medical care. At the present time, microRNAs are detected by long and laborious techniques such as Northern blot, RT-PCR, and microarrays. The originality of our work consists in performing microRNAs detection through an electrochemical genosensor using a label-free method. We were able to directly detect microRNAs without the need of PCR and a labeling reaction. The test is simple, very fast and ultrasensitive, with a detection limit of 0.1 pmol. Particularly feasible for a routine microRNAs detection in serum and other biological samples, our technical approach would be of great scientific value and become a common method for simple miRNAs routine detection in both clinical and research settings.
A new semiquantitative method for evaluation of metastasis progression.
Volarevic, A; Ljujic, B; Volarevic, V; Milovanovic, M; Kanjevac, T; Lukic, A; Arsenijevic, N
2012-01-01
Although recent technical advancements are directed toward developing novel assays and methods for detection of micro and macro metastasis, there are still no reports of reliable, simple to use imaging software that could be used for the detection and quantification of metastasis in tissue sections. We herein report a new semiquantitative method for evaluation of metastasis progression in a well established 4T1 orthotopic mouse model of breast cancer metastasis. The new semiquantitative method presented here was implemented by using the Autodesk AutoCAD 2012 program, a computer-aided design program used primarily for preparing technical drawings in 2 dimensions. By using the Autodesk AutoCAD 2012 software- aided graphical evaluation we managed to detect each metastatic lesion and we precisely calculated the average percentage of lung and liver tissue parenchyma with metastasis in 4T1 tumor-bearing mice. The data were highly specific and relevant to descriptive histological analysis, confirming reliability and accuracy of the AutoCAD 2012 software as new method for quantification of metastatic lesions. The new semiquantitative method using AutoCAD 2012 software provides a novel approach for the estimation of metastatic progression in histological tissue sections.
Use of High Fidelity Methods in Multidisciplinary Optimization-A Preliminary Survey
NASA Technical Reports Server (NTRS)
Guruswamy, Guru P.; Kwak, Dochan (Technical Monitor)
2002-01-01
Multidisciplinary optimization is a key element of design process. To date multidiscipline optimization methods that use low fidelity methods are well advanced. Optimization methods based on simple linear aerodynamic equations and plate structural equations have been applied to complex aerospace configurations. However, use of high fidelity methods such as the Euler/ Navier-Stokes for fluids and 3-D (three dimensional) finite elements for structures has begun recently. As an activity of Multidiscipline Design Optimization Technical Committee (MDO TC) of AIAA (American Institute of Aeronautics and Astronautics), an effort was initiated to assess the status of the use of high fidelity methods in multidisciplinary optimization. Contributions were solicited through the members MDO TC committee. This paper provides a summary of that survey.
Photolithographic surface micromachining of polydimethylsiloxane (PDMS).
Chen, Weiqiang; Lam, Raymond H W; Fu, Jianping
2012-01-21
A major technical hurdle in microfluidics is the difficulty in achieving high fidelity lithographic patterning on polydimethylsiloxane (PDMS). Here, we report a simple yet highly precise and repeatable PDMS surface micromachining method using direct photolithography followed by reactive ion etching (RIE). Our method to achieve surface patterning of PDMS applied an O(2) plasma treatment to PDMS to activate its surface to overcome the challenge of poor photoresist adhesion on PDMS for photolithography. Our photolithographic PDMS surface micromachining technique is compatible with conventional soft lithography techniques and other silicon-based surface and bulk micromachining methods. To illustrate the general application of our method, we demonstrated fabrication of large microfiltration membranes and free-standing beam structures in PDMS.
Photolithographic surface micromachining of polydimethylsiloxane (PDMS)
Chen, Weiqiang; Lam, Raymond H. W.
2014-01-01
A major technical hurdle in microfluidics is the difficulty in achieving high fidelity lithographic patterning on polydimethylsiloxane (PDMS). Here, we report a simple yet highly precise and repeatable PDMS surface micromachining method using direct photolithography followed by reactive ion etching (RIE). Our method to achieve surface patterning of PDMS applied an O2 plasma treatment to PDMS to activate its surface to overcome the challenge of poor photoresist adhesion on PDMS for photolithography. Our photolithographic PDMS surface micromachining technique is compatible with conventional soft lithography techniques and other silicon-based surface and bulk micromachining methods. To illustrate the general application of our method, we demonstrated fabrications of large microfiltration membranes and free-standing beam structures in PDMS. PMID:22089984
ERIC Educational Resources Information Center
Lamberth, Edwin E.
The purpose of this handbook is to present in a simple form the processes and procedures involved in preparing research and development projects in vocational-technical education in the State of Tennessee. It was prepared in conjunction with the Research Coordinating Unit (RCU) and the division of Vocational-Technical Education, State Department…
Furukawa, Masato; Minegishi, Yasutaka; Izumiyama, Shinji; Yagita, Kenji; Mori, Hideto; Uemura, Taku; Etoh, Yoshiki; Maeda, Eriko; Sasaki, Mari; Ichinose, Kazuya; Harada, Seiya; Kamata, Yoichi; Otagiri, Masaki; Sugita-Konishi, Yoshiko; Ohnishi, Takahiro
2016-01-01
Sarcocystis fayeri (S. fayeri) is a newly identified causative agent of foodborne disease that is associated with the consumption of raw horse meat. The testing methods prescribed by the Ministry of Health, Labour and Welfare of Japan are time consuming and require the use of expensive equipment and a high level of technical expertise. Accordingly, these methods are not suitable for use in the routine sanitary control setting to prevent outbreaks of foodborne disease. In order to solve these problems, we have developed a new, rapid and simple testing method using LAMP, which takes only 1 hour to perform and which does not involve the use of any expensive equipment or expert techniques. For the validation of this method, an inter-laboratory study was performed among 5 institutes using 10 samples infected with various concentrations of S. fayeri. The results of the inter-laboratory study demonstrated that our LAMP method could detect S. fayeri at concentrations greater than 10(4) copies/g. Thus, this new method could be useful in screening for S. fayeri as a routine sanitary control procedure.
Immunodiagnosis of childhood malignancies.
Parham, D M; Holt, H
1999-09-01
Immunodiagnosis utilizing immunohistochemical techniques is currently the most commonly utilized and readily available method of ancillary diagnosis in pediatric oncopathology. The methodology comprises relatively simple steps, based on straightforward biologic concepts, and the reagents used are generally well characterized and widely used. The principle of cancer immunodiagnosis is based on the determination of neoplastic lineage using detection of proteins typical of cell differentiation pathways. Methodology sensitivity varies and has become greater with each new generation of tests, but technical draw-backs should be considered to avoid excessive background or nonspecific results. Automated instrumentation offers a degree of accuracy and reproducibility not easily attainable by manual methods.
High-fidelity, low-cost, automated method to assess laparoscopic skills objectively.
Gray, Richard J; Kahol, Kanav; Islam, Gazi; Smith, Marshall; Chapital, Alyssa; Ferrara, John
2012-01-01
We sought to define the extent to which a motion analysis-based assessment system constructed with simple equipment could measure technical skill objectively and quantitatively. An "off-the-shelf" digital video system was used to capture the hand and instrument movement of surgical trainees (beginner level = PGY-1, intermediate level = PGY-3, and advanced level = PGY-5/fellows) while they performed a peg transfer exercise. The video data were passed through a custom computer vision algorithm that analyzed incoming pixels to measure movement smoothness objectively. The beginner-level group had the poorest performance, whereas those in the advanced group generated the highest scores. Intermediate-level trainees scored significantly (p < 0.04) better than beginner trainees. Advanced-level trainees scored significantly better than intermediate-level trainees and beginner-level trainees (p < 0.04 and p < 0.03, respectively). A computer vision-based analysis of surgical movements provides an objective basis for technical expertise-level analysis with construct validity. The technology to capture the data is simple, low cost, and readily available, and it obviates the need for expert human assessment in this setting. Copyright © 2012 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
The use of subjective rating of exertion in Ergonomics.
Capodaglio, P
2002-01-01
In Ergonomics, the use of psychophysical methods for subjectively evaluating work tasks and determining acceptable loads has become more common. Daily activities at the work site are studied not only with physiological methods but also with perceptual estimation and production methods. The psychophysical methods are of special interest in field studies of short-term work tasks for which valid physiological measurements are difficult to obtain. The perceived exertion, difficulty and fatigue that a person experiences in a certain work situation is an important sign of a real or objective load. Measurement of the physical load with physiological parameters is not sufficient since it does not take into consideration the particular difficulty of the performance or the capacity of the individual. It is often difficult from technical and biomechanical analyses to understand the seriousness of a difficulty that a person experiences. Physiological determinations give important information, but they may be insufficient due to the technical problems in obtaining relevant but simple measurements for short-term activities or activities involving special movement patterns. Perceptual estimations using Borg's scales give important information because the severity of a task's difficulty depends on the individual doing the work. Observation is the most simple and used means to assess job demands. Other evaluations integrating observation are the followings: indirect estimation of energy expenditure based on prediction equations or direct measurement of oxygen consumption; measurements of forces, angles and biomechanical parameters; measurements of physiological and neurophysiological parameters during tasks. It is recommended that determinations of performances of occupational activities assess rating of perceived exertion and integrate these measurements of intensity levels with those of activity's type, duration and frequency. A better estimate of the degree of physical activity of individuals thus can be obtained.
Cancer survival: an overview of measures, uses, and interpretation.
Mariotto, Angela B; Noone, Anne-Michelle; Howlader, Nadia; Cho, Hyunsoon; Keel, Gretchen E; Garshell, Jessica; Woloshin, Steven; Schwartz, Lisa M
2014-11-01
Survival statistics are of great interest to patients, clinicians, researchers, and policy makers. Although seemingly simple, survival can be confusing: there are many different survival measures with a plethora of names and statistical methods developed to answer different questions. This paper aims to describe and disseminate different survival measures and their interpretation in less technical language. In addition, we introduce templates to summarize cancer survival statistic organized by their specific purpose: research and policy versus prognosis and clinical decision making. Published by Oxford University Press 2014.
Cancer Survival: An Overview of Measures, Uses, and Interpretation
Noone, Anne-Michelle; Howlader, Nadia; Cho, Hyunsoon; Keel, Gretchen E.; Garshell, Jessica; Woloshin, Steven; Schwartz, Lisa M.
2014-01-01
Survival statistics are of great interest to patients, clinicians, researchers, and policy makers. Although seemingly simple, survival can be confusing: there are many different survival measures with a plethora of names and statistical methods developed to answer different questions. This paper aims to describe and disseminate different survival measures and their interpretation in less technical language. In addition, we introduce templates to summarize cancer survival statistic organized by their specific purpose: research and policy versus prognosis and clinical decision making. PMID:25417231
Klopp, R N; Oconitrillo, M J; Sackett, A; Hill, T M; Schlotterbeck, R L; Lascano, G J
2018-07-01
A limited amount of research is available related to the rumen microbiota of calves, yet there has been a recent spike of interest in determining the diversity and development of calf rumen microbial populations. To study the microbial populations of a calf's rumen, a sample of the rumen fluid is needed. One way to take a rumen fluid sample from a calf is by fistulating the animal. This method requires surgery and can be very stressful on a young animal that is trying to adapt to a new environment and has a depressed immune system. Another method that can be used instead of fistulation surgery is a rumen pump. This method requires a tube to be inserted into the rumen through the calf's esophagus. Once inside the rumen, fluid can be pumped out and collected in a few minutes. This method is quick, inexpensive, and does not cause significant stress on the animal. This technical note presents the materials and methodology used to convert a drenching system into a rumen pump and its respective utilization in 2 experiments using dairy bull calves. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Destruction of giant cluster-like vesicles by an ultrasonically activated device
NASA Astrophysics Data System (ADS)
Yahagi, Ryosuke; Yoshida, Kenji; Zhang, Yiting; Ebata, Masahiko; Toyota, Taro; Yamaguchi, Tadashi; Hayashi, Hideki
2016-07-01
In this paper, we propose a technically simple method of destroying a tissue marker composed of giant cluster-like vesicles (GCVs) to facilitate laparoscopic surgeries; the method releases various biological tracers contained in GCVs. An ultrasonically activated device (USAD) emitting 55.5 kHz ultrasound was employed for this purpose. Optical microscopy and fluorospectrophotometry revealed the destruction of GCVs after ultrasound irradiation when the blade tip was set 1.0 mm or closer to, but not directly in contact with, a GCV-containing cell. This means that USAD could be safely used for destroying this GCV tissue marker in clinical settings.
Qian, Song S; Lyons, Regan E
2006-10-01
We present a Bayesian approach for characterizing background contaminant concentration distributions using data from sites that may have been contaminated. Our method, focused on estimation, resolves several technical problems of the existing methods sanctioned by the U.S. Environmental Protection Agency (USEPA) (a hypothesis testing based method), resulting in a simple and quick procedure for estimating background contaminant concentrations. The proposed Bayesian method is applied to two data sets from a federal facility regulated under the Resource Conservation and Restoration Act. The results are compared to background distributions identified using existing methods recommended by the USEPA. The two data sets represent low and moderate levels of censorship in the data. Although an unbiased estimator is elusive, we show that the proposed Bayesian estimation method will have a smaller bias than the EPA recommended method.
ERIC Educational Resources Information Center
Ucke, C.; Schlichting, H-J.
2009-01-01
Snap discs made of bimetal have many technical applications as thermostats. Jumping discs are a toy version of such snap discs. Besides giving technical information, we describe physical investigations. We show especially how, through simple measurements and calculations, you can determine the initial speed ([approximately equal to]3.5 m…
Javani, Ali; Abolhallaje, Masoud; Jafari, Javad; Fazl Hashemi, Seyed Mohammad Esmaeil
2017-01-01
Background: Achieving organizational objectives depends on the effectiveness of administrators. However, managerial efficacy largely depends on the knowledge and skills of managers. This study aimed at assessing the skills of financial and budget management of the Ministry of Health from the perspective of resource development assistants of universities of medical sciences nationwide. Methods: This cross- sectional study was conducted in 2012. Study participants were resource development assistants of universities of medical sciences in Iran. We adopted simple random sampling method in locating participants. Data were collected using pretested questionnaires and analyzed using descriptive statistics and Mann-Whitney test (as a non-parametric test) and Friedman test. Results: The highest mean recorded under financial management skills was technical skills (3.58±0.50), followed by human skills (3.50±.048), and perceptual skills (3.32±0.52). With regards to financial and budget management and performance monitoring, the means of technical skills, as prioritized by directors, was 3.72±0.71, followed by human skills (3.72±0.70), and perceptual skills (3.66±0.75). A significant association was found between perceptual skills of financial managers and budgeting and performance monitoring managers (p= 0.014). Conclusion: Operational level managers, such as financial and budgetary managers, need to acquire more technical skills. Therefore, we support activities that promote technical skills and awareness of managers within organizations, such as organizational training courses and distribution of educational materials like brochures.
NASA Astrophysics Data System (ADS)
Czerny, J.; Schulz, K. G.; Ludwig, A.; Riebesell, U.
2013-03-01
Mesocosms as large experimental units provide the opportunity to perform elemental mass balance calculations, e.g. to derive net biological turnover rates. However, the system is in most cases not closed at the water surface and gases exchange with the atmosphere. Previous attempts to budget carbon pools in mesocosms relied on educated guesses concerning the exchange of CO2 with the atmosphere. Here, we present a simple method for precise determination of air-sea gas exchange in mesocosms using N2O as a deliberate tracer. Beside the application for carbon budgeting, transfer velocities can be used to calculate exchange rates of any gas of known concentration, e.g. to calculate aquatic production rates of climate relevant trace gases. Using an arctic KOSMOS (Kiel Off Shore Mesocosms for future Ocean Simulation) experiment as an exemplary dataset, it is shown that the presented method improves accuracy of carbon budget estimates substantially. Methodology of manipulation, measurement, data processing and conversion to CO2 fluxes are explained. A theoretical discussion of prerequisites for precise gas exchange measurements provides a guideline for the applicability of the method under various experimental conditions.
NASA Astrophysics Data System (ADS)
Korolev, A. M.; Shulga, V. M.; Turutanov, O. G.; Shnyrkov, V. I.
2016-07-01
A technically simple and physically clear method is suggested for direct measurement of the brightness temperature of two-dimensional electron gas (2DEG) in the channel of a high electron mobility transistor (HEMT). The usage of the method was demonstrated with the pseudomorphic HEMT as a specimen. The optimal HEMT dc regime, from the point of view of the "back action" problem, was found to belong to the unsaturated area of the static characteristics possibly corresponding to the ballistic electron transport mode. The proposed method is believed to be a convenient tool to explore the ballistic transport, electron diffusion, 2DEG properties and other electrophysical processes in heterostructures.
Numerical Polynomial Homotopy Continuation Method and String Vacua
Mehta, Dhagash
2011-01-01
Finding vmore » acua for the four-dimensional effective theories for supergravity which descend from flux compactifications and analyzing them according to their stability is one of the central problems in string phenomenology. Except for some simple toy models, it is, however, difficult to find all the vacua analytically. Recently developed algorithmic methods based on symbolic computer algebra can be of great help in the more realistic models. However, they suffer from serious algorithmic complexities and are limited to small system sizes. In this paper, we review a numerical method called the numerical polynomial homotopy continuation (NPHC) method, first used in the areas of lattice field theories, which by construction finds all of the vacua of a given potential that is known to have only isolated solutions. The NPHC method is known to suffer from no major algorithmic complexities and is embarrassingly parallelizable , and hence its applicability goes way beyond the existing symbolic methods. We first solve a simple toy model as a warm-up example to demonstrate the NPHC method at work. We then show that all the vacua of a more complicated model of a compactified M theory model, which has an S U ( 3 ) structure, can be obtained by using a desktop machine in just about an hour, a feat which was reported to be prohibitively difficult by the existing symbolic methods. Finally, we compare the various technicalities between the two methods.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, C.
Almost every computer architect dreams of achieving high system performance with low implementation costs. A multigauge machine can reconfigure its data-path width, provide parallelism, achieve better resource utilization, and sometimes can trade computational precision for increased speed. A simple experimental method is used here to capture the main characteristics of multigauging. The measurements indicate evidence of near-optimal speedups. Adapting these ideas in designing parallel processors incurs low costs and provides flexibility. Several operational aspects of designing a multigauge machine are discussed as well. Thus, this research reports the technical, economical, and operational feasibility studies of multigauging.
An inquiry into computer understanding
NASA Technical Reports Server (NTRS)
Cheeseman, Peter
1988-01-01
The paper examines issues connected with the choice of the best method for representing and reasoning about common sense. McDermott (1978) has shown that a direct translation of common sense reasoning into logical form leads to insurmountable difficulties. It is shown, in the present work, that if Bayesian probability is used instead of logic as the language of such reasoning, none of the technical difficulties found in using logic arise. Bayesian inference is applied to a simple example of linguistic information to illustrate the potential of this type of inference for artificial intelligence.
Henderson, Fraser; Takacs, Istvan
2017-01-01
Troubleshooting of deep brain stimulators (DBSs, Activa SC/PC/RC Medtronic PLC, Minneapolis, Minnesota, USA) sometimes results in a decision to replace a tunneled stretch-coil extension cable. We present a simple technique to accomplish this atraumatically without a tunneling tool. In the treatment of patients with a DBS, complication avoidance and efficiency of operative time are paramount. We sought to find the safest, most effective, and fastest method of performing the conceptually simple yet technically nuanced act of replacing lead extension cables. We connected #6 (8.0 metric) surgical steel 18″ (45-cm) monofilament (Ethicon US, LLC, Somerville, New Jersey, USA), also known as #6 sternal wire, in line with DBS extension cables (Medtronic DBS Extension 37086-60) in novel fashion to overcome intraprocedural hurdles encountered during the past decade in a busy functional neurosurgery service. Patients tolerate the procedure well and return home shortly after recovery with no complications. A less expensive and faster technique for passing pulse generator extension cables may be the use of a sternal wire. Using the described technique, pulse generators may be quickly and safely adjusted from side to side and site to site as the clinical situation dictates. Copyright © 2016 Elsevier Inc. All rights reserved.
Model of Pressure Distribution in Vortex Flow Controls
NASA Astrophysics Data System (ADS)
Mielczarek, Szymon; Sawicki, Jerzy M.
2015-06-01
Vortex valves belong to the category of hydrodynamic flow controls. They are important and theoretically interesting devices, so complex from hydraulic point of view, that probably for this reason none rational concept of their operation has been proposed so far. In consequence, functioning of vortex valves is described by CFD-methods (computer-aided simulation of technical objects) or by means of simple empirical relations (using discharge coefficient or hydraulic loss coefficient). Such rational model of the considered device is proposed in the paper. It has a simple algebraic form, but is well grounded physically. The basic quantitative relationship, which describes the valve operation, i.e. dependence between the flow discharge and the circumferential pressure head, caused by the rotation, has been verified empirically. Conformity between calculated and measured parameters of the device allows for acceptation of the proposed concept.
Eyewitness report on Chinese satellite work
NASA Technical Reports Server (NTRS)
Edelson, B.; Haas, S.; Harford, J.; Jaffe, L.; Nansen, R.; Schnapf, A.; Yarymovych, M.
1980-01-01
The article describes the current status of satellite and related technology in the People's Republic of China. Attention is given to areas of potential cooperation and scientific and technical 'exchanges'. It is reported that the Chinese technology is 'advanced, but simple' and that the Chinese showed great interest in receiving U.S. technical know-how.
Work Measurement as a Generalized Quantum Measurement
NASA Astrophysics Data System (ADS)
Roncaglia, Augusto J.; Cerisola, Federico; Paz, Juan Pablo
2014-12-01
We present a new method to measure the work w performed on a driven quantum system and to sample its probability distribution P (w ). The method is based on a simple fact that remained unnoticed until now: Work on a quantum system can be measured by performing a generalized quantum measurement at a single time. Such measurement, which technically speaking is denoted as a positive operator valued measure reduces to an ordinary projective measurement on an enlarged system. This observation not only demystifies work measurement but also suggests a new quantum algorithm to efficiently sample the distribution P (w ). This can be used, in combination with fluctuation theorems, to estimate free energies of quantum states on a quantum computer.
Haeufle, D F B; Günther, M; Wunner, G; Schmitt, S
2014-01-01
In biomechanics and biorobotics, muscles are often associated with reduced movement control effort and simplified control compared to technical actuators. This is based on evidence that the nonlinear muscle properties positively influence movement control. It is, however, open how to quantify the simplicity aspect of control effort and compare it between systems. Physical measures, such as energy consumption, stability, or jerk, have already been applied to compare biological and technical systems. Here a physical measure of control effort based on information entropy is presented. The idea is that control is simpler if a specific movement is generated with less processed sensor information, depending on the control scheme and the physical properties of the systems being compared. By calculating the Shannon information entropy of all sensor signals required for control, an information cost function can be formulated allowing the comparison of models of biological and technical control systems. Exemplarily applied to (bio-)mechanical models of hopping, the method reveals that the required information for generating hopping with a muscle driven by a simple reflex control scheme is only I=32 bits versus I=660 bits with a DC motor and a proportional differential controller. This approach to quantifying control effort captures the simplicity of a control scheme and can be used to compare completely different actuators and control approaches.
NASA Technical Reports Server (NTRS)
1979-01-01
The photos show automobile engines being tested for nitrous oxide emissions, as required by the Environmental Protection Agency (EPA), at the Research and Engineering Division of Ford Motor Company, Dearborn. Michigan. NASA technical information helped the company develop a means of calculating emissions test results. Nitrous oxide emission readings vary with relative humidity in the test facility. EPA uses a standard humidity measurement, but the agency allows manufacturers to test under different humidity conditions, then apply a correction factor to adjust the results to the EPA standard. NASA's Dryden Flight Research Center developed analytic equations which provide a simple, computer-programmable method of correcting for humidity variations. A Ford engineer read a NASA Tech Brief describing the Dryden development and requested more detailed information in the form of a technical support package, which NASA routinely supplies to industry on request. Ford's Emissions Test Laboratory now uses the Dryden equations for humidity-adjusted emissions data reported to EPA.
Aghayev, Kamran; Vrionis, Frank D
2013-09-01
The main aim of this paper was to report reproducible method of lumbar spine access via a lateral retroperitoneal route. The authors conducted a retrospective analysis of the technical aspects and clinical outcomes of six patients who underwent lateral multilevel retroperitoneal interbody fusion with psoas muscle retraction technique. The main goal was to develop a simple and reproducible technique to avoid injury to the lumbar plexus. Six patients were operated at 15 levels using psoas muscle retraction technique. All patients reported improvement in back pain and radiculopathy after the surgery. The only procedure-related transient complication was weakness and pain on hip flexion that resolved by the first follow-up visit. Psoas retraction technique is a reliable technique for lateral access to the lumbar spine and may avoid some of the complications related to traditional minimally invasive transpsoas approach.
Hawkins, K A; Tulsky, D S
2001-11-01
Since memory performance expectations may be IQ-based, unidirectional base rate data for IQ-Memory Score discrepancies are provided in the WAIS-III/WMS-III Technical Manual. The utility of these data partially rests on the assumption that discrepancy base rates do not vary across ability levels. FSIQ stratified base rate data generated from the standardization sample, however, demonstrate substantial variability across the IQ spectrum. A superiority of memory score over FSIQ is typical at lower IQ levels, whereas the converse is true at higher IQ levels. These data indicate that the use of IQ-memory score unstratified "simple difference" tables could lead to erroneous conclusions for clients with low or high IQ. IQ stratified standardization base rate data are provided as a complement to the "predicted difference" method detailed in the Technical Manual.
A general method for bead-enhanced quantitation by flow cytometry
Montes, Martin; Jaensson, Elin A.; Orozco, Aaron F.; Lewis, Dorothy E.; Corry, David B.
2009-01-01
Flow cytometry provides accurate relative cellular quantitation (percent abundance) of cells from diverse samples, but technical limitations of most flow cytometers preclude accurate absolute quantitation. Several quantitation standards are now commercially available which, when added to samples, permit absolute quantitation of CD4+ T cells. However, these reagents are limited by their cost, technical complexity, requirement for additional software and/or limited applicability. Moreover, few studies have validated the use of such reagents in complex biological samples, especially for quantitation of non-T cells. Here we show that addition to samples of known quantities of polystyrene fluorescence standardization beads permits accurate quantitation of CD4+ T cells from complex cell samples. This procedure, here termed single bead-enhanced cytofluorimetry (SBEC), was equally capable of enumerating eosinophils as well as subcellular fragments of apoptotic cells, moieties with very different optical and fluorescent characteristics. Relative to other proprietary products, SBEC is simple, inexpensive and requires no special software, suggesting that the method is suitable for the routine quantitation of most cells and other particles by flow cytometry. PMID:17067632
A simple technic for repeated collection of blood samples from mice.
Stoltz, D R; Bendall, R D
1975-06-01
A device for repeated collection of small blood samples from mice was constructed from a plastic syringe. Blood was collected into a 3.33 lambda capillary tube. Bleeding was stopped by a hemostat made from a rubber stopper. This technic allows easy collection of approximately 20 serial samples within an 8-hr period.
ERIC Educational Resources Information Center
Thorne, Scott
2000-01-01
Explains why the data warehouse is important to the Massachusetts Institute of Technology community, describing its basic functions and technical design points; sharing some non-technical aspects of the school's data warehouse implementation that have proved to be important; examining the importance of proper training in a successful warehouse…
Using Probabilistic Information in Solving Resource Allocation Problems for a Decentralized Firm
1978-09-01
deterministic equivalent form of HIQ’s problem (5) by an approach similar to the one used in stochastic programming with simple recourse. See Ziemba [38) or, in...1964). 38. Ziemba , W.T., "Stochastic Programs with Simple Recourse," Technical Report 72-15, Stanford University, Department of Operations Research
Kim, Sanggil; Ko, Wooseok; Sung, Bong Hyun; Kim, Sun Chang; Lee, Hyun Soo
2016-11-15
Proteins often function as complex structures in conjunction with other proteins. Because these complex structures are essential for sophisticated functions, developing protein-protein conjugates has gained research interest. In this study, site-specific protein-protein conjugation was performed by genetically incorporating an azide-containing amino acid into one protein and a bicyclononyne (BCN)-containing amino acid into the other. Three to four sites in each of the proteins were tested for conjugation efficiency, and three combinations showed excellent conjugation efficiency. The genetic incorporation of unnatural amino acids (UAAs) is technically simple and produces the mutant protein in high yield. In addition, the conjugation reaction can be conducted by simple mixing, and does not require additional reagents or linker molecules. Therefore, this method may prove very useful for generating protein-protein conjugates and protein complexes of biochemical significance. Copyright © 2016. Published by Elsevier Ltd.
Aircraft stress sequence development: A complex engineering process made simple
NASA Technical Reports Server (NTRS)
Schrader, K. H.; Butts, D. G.; Sparks, W. A.
1994-01-01
Development of stress sequences for critical aircraft structure requires flight measured usage data, known aircraft loads, and established relationships between aircraft flight loads and structural stresses. Resulting cycle-by-cycle stress sequences can be directly usable for crack growth analysis and coupon spectra tests. Often, an expert in loads and spectra development manipulates the usage data into a typical sequence of representative flight conditions for which loads and stresses are calculated. For a fighter/trainer type aircraft, this effort is repeated many times for each of the fatigue critical locations (FCL) resulting in expenditure of numerous engineering hours. The Aircraft Stress Sequence Computer Program (ACSTRSEQ), developed by Southwest Research Institute under contract to San Antonio Air Logistics Center, presents a unique approach for making complex technical computations in a simple, easy to use method. The program is written in Microsoft Visual Basic for the Microsoft Windows environment.
Chapin, Thomas; Todd, Andrew S.; Zeigler, Matthew P.
2014-01-01
Water temperature and streamflow intermittency are critical parameters influencing aquatic ecosystem health. Low-cost temperature loggers have made continuous water temperature monitoring relatively simple but determining streamflow timing and intermittency using temperature data alone requires significant and subjective data interpretation. Electrical resistance (ER) sensors have recently been developed to overcome the major limitations of temperature-based methods for the assessment of streamflow intermittency. This technical note introduces the STIC (Stream Temperature, Intermittency, and Conductivity logger); a robust, low-cost, simple to build instrument that provides long-duration, high-resolution monitoring of both relative conductivity (RC) and temperature. Simultaneously collected temperature and RC data provide unambiguous water temperature and streamflow intermittency information that is crucial for monitoring aquatic ecosystem health and assessing regulatory compliance. With proper calibration, the STIC relative conductivity data can be used to monitor specific conductivity.
Chai, Norin; Pouchelon, Jean Louis; Bouvard, Jonathan; Sillero, Leonor Camacho; Huynh, Minh; Segalini, Vincent; Point, Lisa; Croce, Veronica; Rigaux, Goulven; Highwood, Jack; Chetboul, Valérie
2016-03-01
Electrocardiography represents a relevant diagnostic tool for detecting cardiac disease in animals. Elephants can present various congenital and acquired cardiovascular diseases. However, few electrophysiologic studies have been reported in captive elephants, mainly due to challenging technical difficulties in obtaining good-quality electrocardiogram (ECG) tracings, and no data are currently available for free-ranging Asian elephants (Elephas maximus). The purpose of this pilot prospective study was to evaluate the feasibility of using a simple method for recording ECG tracings in wild, apparently healthy, unsedated Asian elephants (n = 7) in the standing position. Successful six-lead recordings (I, II, III, aVR, aVL, and aVF) were obtained, with the aVL lead providing the best-quality tracings in most animals. Variables measured in the aVL lead included heart rate, amplitudes and duration of the P waves, QRS complexes, T and U waves, and duration of the PR, QT, and QU intervals. A negative deflection following positive P waves, representative of an atrial repolarization wave (Ta wave), was observed for five out of the seven elephants.
Kumaresan, Ramesh; Ponnusami, Karthikeyan; Karthikeyan, Priyadarshini
2014-12-01
The treatment of maxillofacial fractures involves different methods from bandages and splinting to methods of open reduction and internal fixation and usually requires control of the dental occlusion with the help of intermaxillary fixation (IMF). Different wiring techniques have been used to aid in IMF including placement of custom-made arch bars, eyelet etc. However, these wiring techniques are with a constant danger of trauma to the surgeon's fingers by their sharp ends. Though there exist a variety of commercially available barrier products and customized techniques to prevent wire-stick injury, cost factor, touch sensitivity, and comfort aspect restrain their acquirement and exploit. This technical note describes the construction of a simple and economical finger guard made of soft thermoplastic material that provides an added protection to fingers from wire-stick type injuries, and its flexible nature permits a comfortable finger flexion movement and acceptable touch sensitivity. This is a simple, economical, reusable puncture, and cut-resistance figure guard by which we can avoid wire-stick type injury to the operator's fingers during wiring technique.
Clustering biomolecular complexes by residue contacts similarity.
Rodrigues, João P G L M; Trellet, Mikaël; Schmitz, Christophe; Kastritis, Panagiotis; Karaca, Ezgi; Melquiond, Adrien S J; Bonvin, Alexandre M J J
2012-07-01
Inaccuracies in computational molecular modeling methods are often counterweighed by brute-force generation of a plethora of putative solutions. These are then typically sieved via structural clustering based on similarity measures such as the root mean square deviation (RMSD) of atomic positions. Albeit widely used, these measures suffer from several theoretical and technical limitations (e.g., choice of regions for fitting) that impair their application in multicomponent systems (N > 2), large-scale studies (e.g., interactomes), and other time-critical scenarios. We present here a simple similarity measure for structural clustering based on atomic contacts--the fraction of common contacts--and compare it with the most used similarity measure of the protein docking community--interface backbone RMSD. We show that this method produces very compact clusters in remarkably short time when applied to a collection of binary and multicomponent protein-protein and protein-DNA complexes. Furthermore, it allows easy clustering of similar conformations of multicomponent symmetrical assemblies in which chain permutations can occur. Simple contact-based metrics should be applicable to other structural biology clustering problems, in particular for time-critical or large-scale endeavors. Copyright © 2012 Wiley Periodicals, Inc.
Clean Water for Developing Countries.
Pandit, Aniruddha B; Kumar, Jyoti Kishen
2015-01-01
Availability of safe drinking water, a vital natural resource, is still a distant dream to many around the world, especially in developing countries. Increasing human activity and industrialization have led to a wide range of physical, chemical, and biological pollutants entering water bodies and affecting human lives. Efforts to develop efficient, economical, and technologically sound methods to produce clean water for developing countries have increased worldwide. We focus on solar disinfection, filtration, hybrid filtration methods, treatment of harvested rainwater, herbal water disinfection, and arsenic removal technologies. Simple, yet innovative water treatment devices ranging from use of plant xylem as filters, terafilters, and hand pumps to tippy taps designed indigenously are methods mentioned here. By describing the technical aspects of major water disinfection methods relevant for developing countries on medium to small scales and emphasizing their merits, demerits, economics, and scalability, we highlight the current scenario and pave the way for further research and development and scaling up of these processes. This review focuses on clean drinking water, especially for rural populations in developing countries. It describes various water disinfection techniques that are not only economically viable and energy efficient but also employ simple methodologies that are effective in reducing the physical, chemical, and biological pollutants found in drinking water to acceptable limits.
From properties to materials: An efficient and simple approach.
Huwig, Kai; Fan, Chencheng; Springborg, Michael
2017-12-21
We present an inverse-design method, the poor man's materials optimization, that is designed to identify materials within a very large class with optimized values for a pre-chosen property. The method combines an efficient genetic-algorithm-based optimization, an automatic approach for generating modified molecules, a simple approach for calculating the property of interest, and a mathematical formulation of the quantity whose value shall be optimized. In order to illustrate the performance of our approach, we study the properties of organic molecules related to those used in dye-sensitized solar cells, whereby we, for the sake of proof of principle, consider benzene as a simple test system. Using a genetic algorithm, the substituents attached to the organic backbone are varied and the best performing molecules are identified. We consider several properties to describe the performance of organic molecules, including the HOMO-LUMO gap, the sunlight absorption, the spatial distance of the orbitals, and the reorganisation energy. The results show that our method is able to identify a large number of good candidate structures within a short time. In some cases, chemical/physical intuition can be used to rationalize the substitution pattern of the best structures, although this is not always possible. The present investigations provide a solid foundation for dealing with more complex and technically relevant systems such as porphyrins. Furthermore, our "properties first, materials second" approach is not limited to solar-energy harvesting but can be applied to many other fields, as briefly is discussed in the paper.
From properties to materials: An efficient and simple approach
NASA Astrophysics Data System (ADS)
Huwig, Kai; Fan, Chencheng; Springborg, Michael
2017-12-01
We present an inverse-design method, the poor man's materials optimization, that is designed to identify materials within a very large class with optimized values for a pre-chosen property. The method combines an efficient genetic-algorithm-based optimization, an automatic approach for generating modified molecules, a simple approach for calculating the property of interest, and a mathematical formulation of the quantity whose value shall be optimized. In order to illustrate the performance of our approach, we study the properties of organic molecules related to those used in dye-sensitized solar cells, whereby we, for the sake of proof of principle, consider benzene as a simple test system. Using a genetic algorithm, the substituents attached to the organic backbone are varied and the best performing molecules are identified. We consider several properties to describe the performance of organic molecules, including the HOMO-LUMO gap, the sunlight absorption, the spatial distance of the orbitals, and the reorganisation energy. The results show that our method is able to identify a large number of good candidate structures within a short time. In some cases, chemical/physical intuition can be used to rationalize the substitution pattern of the best structures, although this is not always possible. The present investigations provide a solid foundation for dealing with more complex and technically relevant systems such as porphyrins. Furthermore, our "properties first, materials second" approach is not limited to solar-energy harvesting but can be applied to many other fields, as briefly is discussed in the paper.
Technical editing and the effective communication of scientific results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pieper, G.W.; Picologlou, S.M.
1996-05-01
Communication of scientific results--whether for professional journals, poster sessions, oral presentations, or the popular press--is an essential part of any scientific investigation. The technical editor plays an important rolein ensuring that scientists express their results correctly and effectively. Technical editing comprises far more than simple proofreading. The editor`s tasks may range from restructuring whole parpagrphs and suggesting improved graphical aids to writing abstracts and preparing first drafts of proposals. The technical editor works closely with scientists to present complex ideas to differentaudiences, including fellow scentists, funding agencies, and the general public. New computer technologyhas also involved the technical editor notmore » only with on-line editing but also with preparing CD ROMs and World Wide Web pages.« less
Meningomyelocele Simulation Model: Pre-surgical Management–Technical Report
Angert, Robert M
2018-01-01
This technical report describes the creation of a myelomeningocele model of a newborn baby. This is a simple, low-cost, and easy-to-assemble model that allows the medical team to practice the delivery room management of a newborn with myelomeningocele. The report includes scenarios and a suggested checklist with which the model can be employed. PMID:29713576
If Not Us, Then Who? Increasing Opportunities for Students at Navajo Technical University
ERIC Educational Resources Information Center
Vandever, Daniel
2017-01-01
Navajo Technical University first opened its doors in 1979 as the Navajo Skills Center with the simple intention of training an unemployed workforce and putting people to work. At the time, the Diné were just a generation removed from attempts at forced assimilation, which included unwarranted military action by the U.S. Cavalry during the Long…
Flexible Authoring and Delivery of Online Courses Using IMS Learning Design
ERIC Educational Resources Information Center
Hermans, Henry; Janssen, José; Koper, Rob
2016-01-01
Since the publication of the IMS Learning Design (IMS LD) specification in 2003, many initiatives have been undertaken to build authoring tools that are simple enough to be used by non-technical instructors and teachers. IMS LD's technical complexity is believed to be a major burden for the adoption of the specification. We have developed a new…
Meningomyelocele Simulation Model: Pre-surgical Management-Technical Report.
Rosen, Orna; Angert, Robert M
2018-02-26
This technical report describes the creation of a myelomeningocele model of a newborn baby. This is a simple, low-cost, and easy-to-assemble model that allows the medical team to practice the delivery room management of a newborn with myelomeningocele. The report includes scenarios and a suggested checklist with which the model can be employed.
Mathematical Astronomy in India
NASA Astrophysics Data System (ADS)
Plofker, Kim
Astronomy in South Asia's Sanskrit tradition, apparently originating in simple calendric computations regulating the timing of ancient ritual practices, expanded over the course of two or three millennia to include detailed spherical models, an endless variety of astrological systems, and academic mathematics in general. Assimilating various technical models, methods, and genres from the astronomy of neighboring cultures, Indian astronomers created new forms that were in turn borrowed by their foreign counterparts. Always recognizably related to the main themes of Eurasian geocentric mathematical astronomy, Indian astral science nonetheless maintained its culturally distinct character until Keplerian heliocentrism and Newtonian mechanics replaced it in colonial South Asia's academic mainstream.
On a computational model of building thermal dynamic response
NASA Astrophysics Data System (ADS)
Jarošová, Petra; Vala, Jiří
2016-07-01
Development and exploitation of advanced materials, structures and technologies in civil engineering, both for buildings with carefully controlled interior temperature and for common residential houses, together with new European and national directives and technical standards, stimulate the development of rather complex and robust, but sufficiently simple and inexpensive computational tools, supporting their design and optimization of energy consumption. This paper demonstrates the possibility of consideration of such seemingly contradictory requirements, using the simplified non-stationary thermal model of a building, motivated by the analogy with the analysis of electric circuits; certain semi-analytical forms of solutions come from the method of lines.
Experimental Study on the Treatment of low C/N ratio disposal of sewage with BAF
NASA Astrophysics Data System (ADS)
Wang, W. J.; Ma, T.; Cheng, W.
2010-03-01
The Biological Aerated Filter (BAF) is a simple, high-efficient, low-consumptive for new biological membrane method correspond to the situation of china, will be one of the main technical measures to solve the progressive deterioration of water environment problem faced china especially medium and small towns. This paper focuses on the experimental study and mechanism analysis in which the up flow, cocurrent gas-water, single-stage BAF was adopted on treatment domestic wastewater, the results showed that BAF has good performance in treating domestic sewage, and it had steady treatment effect with different pollution loads.
Design Features of a Friendly Software Environment for Novice Programmers. Technical Report No. 3.
ERIC Educational Resources Information Center
Eisenstadt, Marc
This paper describes the results of a 6-year period of design, implementation, testing, and iterative redesign of a programming language, user aids, and curriculum materials for use by psychology students learning how to write simple computer programs. The SOLO language, which was the resulting product, is primarily a simple, database…
Schulze, G; Jung, K; Kunze, D; Egger, E
1976-01-01
The preparation of PC with the 14C-fatty acids palmitic, stearic, oleic and linoleic acid at OH-group in position 2 is described. The starting material is egg yolk lecithin. By the attack of snake venom phospholiphase lyso-PC is produced which is reacylated by the appropriate fatty acid anhydride. In comparison with the methods published up to now this preparation has the advantage of higher yields and greater simplicity. By means of in vivo synthesis it is impossible to get PC species with only one fatty acid in a defined position. Working with radioactive fatty acids the specific radioactivity can be adapted to the requirements. The procedure can be made on a semi-technical scale.
ERIC Educational Resources Information Center
Leonchuk, Olena
2016-01-01
This dissertation builds on an alternative framework for evaluation of science, technology and innovation (STI) outcomes--the scientific & technical (S&T) human capital which was developed by Bozeman, Dietz and Gaughan (2001). At its core, this framework looks beyond simple economic and publication metrics and instead focuses on…
Japanese professional nurses spend unnecessarily long time doing nursing assistants' tasks.
Kudo, Yasushi; Yoshimura, Emiko; Shahzad, Machiko Taruzuka; Shibuya, Akitaka; Aizawa, Yoshiharu
2012-09-01
In environments in which professional nurses do simple tasks, e.g., laundry, cleaning, and waste disposal, they cannot concentrate on technical jobs by utilizing their expertise to its fullest benefit. Particularly, in Japan, the nursing shortage is a serious problem. If professional nurses take their time to do any of these simple tasks, the tasks should be preferentially allocated to nursing assistants. Because there has been no descriptive study to investigate the amount of time Japanese professional nurses spent doing such simple tasks during their working time, their actual conditions remain unclear. Professional nurses recorded their total working time and the time they spent doing such simple tasks during the week of the survey period. The time an individual respondent spent doing one or more simple tasks during that week was summed up, as was their working time. Subsequently, the percentage of the summed time he or she spent doing any of those tasks in his or her summed working time was calculated. A total of 1,086 respondents in 19 hospitals that had 87 to 376 beds were analyzed (response rate: 53.3%). The average time (SD) that respondents spent doing those simple tasks and their total working time were 2.24 (3.35) hours and 37.48 (10.88) hours, respectively. The average percentage (SD) of the time they spent doing the simple tasks in their working time was 6.00% (8.39). Hospital administrators must decrease this percentage. Proper working environments in which professional nurses can concentrate more on their technical jobs must be created.
Quick, Jacob A; MacIntyre, Allan D; Barnes, Stephen L
2014-02-01
Surgical airway creation has a high potential for disaster. Conventional methods can be cumbersome and require special instruments. A simple method utilizing three steps and readily available equipment exists, but has yet to be adequately tested. Our objective was to compare conventional cricothyroidotomy with the three-step method utilizing high-fidelity simulation. Utilizing a high-fidelity simulator, 12 experienced flight nurses and paramedics performed both methods after a didactic lecture, simulator briefing, and demonstration of each technique. Six participants performed the three-step method first, and the remaining 6 performed the conventional method first. Each participant was filmed and timed. We analyzed videos with respect to the number of hand repositions, number of airway instrumentations, and technical complications. Times to successful completion were measured from incision to balloon inflation. The three-step method was completed faster (52.1 s vs. 87.3 s; p = 0.007) as compared with conventional surgical cricothyroidotomy. The two methods did not differ statistically regarding number of hand movements (3.75 vs. 5.25; p = 0.12) or instrumentations of the airway (1.08 vs. 1.33; p = 0.07). The three-step method resulted in 100% successful airway placement on the first attempt, compared with 75% of the conventional method (p = 0.11). Technical complications occurred more with the conventional method (33% vs. 0%; p = 0.05). The three-step method, using an elastic bougie with an endotracheal tube, was shown to require fewer total hand movements, took less time to complete, resulted in more successful airway placement, and had fewer complications compared with traditional cricothyroidotomy. Published by Elsevier Inc.
Solar, Install, Mount, Production, Labor, Equipment Balance of Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gentry, Russell; Al-Haddad, Tristan; Valdes, Francisco
2015-08-27
The GTRI led project team in partnership with the DOE, universities, and numerous industry leaders, have advanced the mission of the DOE EERE, the Solar Energy Technologies Program, and the SunShot Initiative by accelerating the research, development, and demonstration of solar PV technologies that provide Extreme Balance of Systems Cost Reductions (BOS-X). The research produced 132 design concepts, resulting in 19 invention disclosures, five patent applications, four 90% pre-commercial designs, and three licensed technologies. Technology practice rights were obtained by an industry partner, and a new solar commercial start-up company was launched in Atlanta as a result of this project.more » Innovations in residential, commercial, and utility scale balance of systems technologies were realized through an unprecedented multi-disciplinary university/industry partnership with over 50 students and 24 faculty members that produced 18 technical publications, a PhD thesis, and two commercially deployed operating prototypes. The technical effectiveness and economic feasibility of the multidisciplinary systems based approach executed by the project team was realized through 1) a comprehensive evaluation of industry, regulatory, and public stakeholder requirements; 2) numerous industry/student/faculty engagements in design studios, technical conferences, and at solar PV installation sites; 3) time and motion studies with domain experts that provided technical data and costs for each phase and component of the solar PV installation processes; 4) extensive wind tunnel and systems engineering modeling; and 5) design, construction, and demonstration of the selected technologies in the field at high profile sites in Atlanta. The SIMPLE BOS project has benefitted the public in the following ways: • Workforce development: The launch of a start-up company to commercialize the DOE funded SIMPLE BoS designs has directly created 9 new jobs in the State of Georgia. As of November 2014, the Georgia solar industry employs 2,890 solar workers, representing a 12.8% growth in employment over 2013 (Solar Jobs Census, 2014). • Growth of the solar industry: The DOE SIMPLE BoS SunShot Award to GTARC accelerated the growth of the solar industry in Georgia, due to the national publicity of the award and the engagement of numerous solar PV manufacturers, designers, and installers on the SIMPLE BoS project. In 2011 less than 50 megawatts of solar PV capacity existed in Georgia; by 2016 Georgia may reach nearly 800 MW of total approved solar capacity with the 2012 Georgia Power Advanced Solar Initiative. • Technical outreach and publications: Georgia Tech has participated in numerous technical symposiums, technology demonstrations, campus solar PV tours, and produced 18 publications for the solar industry and general public. • Cost reductions for consumers: The SIMPLE BoS pre-commercial systems and discoveries enable cost reductions of 50% or more in labor and materials for residential, commercial and utility scale PV installations.« less
SIMPLE GREEN® 2013 Reformulation
Technical product bulletin: this surface washing agent used in oil spill cleanups is equally effective in fresh water, estuarine, and marine environments at all temperatures. Spray directly on surface of oil.
Technical product bulletin: this water based surface washing agent used in oil spill cleanups is equally effective in fresh water, estuarine, and marine environments at all temperatures. Spray directly on surface of oil.
Method for loading lipid like vesicles with drugs of other chemicals
Mehlhorn, R.J.
1998-06-09
A method for accumulating drugs or other chemicals within synthetic, lipid-like vesicles by means of a pH gradient imposed on the vesicles just prior to use is described. The method is suited for accumulating molecules with basic or acid moieties which are permeable to the vesicles membranes in their uncharged form and for molecules that contain charge moieties that are hydrophobic ions and can therefore cross the vesicle membranes in their charged form. The method is advantageous over prior art methods for encapsulating biologically active materials within vesicles in that is achieves very high degrees of loading with simple procedures that are economical and require little technical expertise, furthermore kits which can be stored for prolonged periods prior to use without impairment of the capacity to achieve drug accumulation are described. A related application of the method consists of using this technology to detoxify animals that have been exposed to poisons with basic, weak acid or hydrophobic charge groups within their molecular structures. 2 figs.
Method for loading lipid like vesicles with drugs of other chemicals
Mehlhorn, Rolf Joachim
1998-01-01
A method for accumulating drugs or other chemicals within synthetic, lipid-like vesicles by means of a pH gradient imposed on the vesicles just prior to use is described. The method is suited for accumulating molecules with basic or acid moieties which are permeable to the vesicles membranes in their uncharged form and for molecules that contain charge moieties that are hydrophobic ions and can therefore cross the vesicle membranes in their charged form. The method is advantageous over prior art methods for encapsulating biologically active materials within vesicles in that is achieves very high degrees of loading with simple procedures that are economical and require little technical expertise, furthermore kits which can be stored for prolonged periods prior to use without impairment of the capacity to achieve drug accumulation are described. A related application of the method consists of using this technology to detoxify animals that have been exposed to poisons with basic, weak acid or hydrophobic charge groups within their molecular structures.
Method of detoxifying animal suffering from overdose
Mehlhorn, Rolf J.
1997-01-01
A method for accumulating drugs or other chemicals within synthetic, lipid-like vesicles by means of a pH gradient imposed on the vesicles just prior to use is described. The method is suited for accumulating molecules with basic or acid moieties which are permeable to the vesicles membranes in their uncharged form and for molecules that contain charge moieties that are hydrophobic ions and can therefore cross the vesicle membranes in their charged form. The method is advantageous over prior art methods for encapsulating biologically active materials within vesicles in that it achieves very high degrees of loading with simple procedures that are economical and require little technical expertise, furthermore kits which can be stored for prolonged periods prior to use without impairment of the capacity to achieve drug accumulation are described. A related application of the method consists of using this technology to detoxify animals that have been exposed to poisons with basic, weak acid or hydrophobic charge groups within their molecular structure.
NASA Technical Reports Server (NTRS)
Selcuk, M. K.; Fujita, T.
1984-01-01
A simple graphical method was developed to undertake technical design trade-off studies for individual parabolic dish models comprising a two-axis tracking parabolic dish with a cavity receiver and power conversion assembly at the focal point. The results of these technical studies are then used in performing the techno-economic analyses required for determining appropriate subsystem sizing. Selected graphs that characterize the performance of subsystems within the module were arranged in the form of a nomogram that would enable an investigator to carry out several design trade-off studies. Key performance parameters encompassed in the nomogram include receiver losses, intercept factor, engine rating, and engine efficiency. Design and operation parameters such as concentrator size, receiver type (open or windowed aperture), receiver aperture size, operating temperature of the receiver and engine, engine partial load characteristics, concentrator slope error, and the type of reflector surface, are also included in the graphical solution. Cost considerations are not included.
Matsumoto, Kenjiro; Kimura, Hiroshi; Tashima, Kimihito; Uchida, Masayuki; Horie, Syunji
2008-10-01
Several methods are used to evaluate gastric motility in rodents, but they all have technical limitations. Recent technical developments enable a convenient method to evaluate gastric motility. The (13)C-acetic acid breath test in rodents is a non-invasive and repeatable method that can be used without physical restraints. The present study aimed to validate the (13)C-acetic acid breath test by measuring the effects of loperamide, morphine, mosapride, and itopride on gastric emptying in mice. Loperamide (1-10 mg/kg) and morphine (1.25-10 mg/kg) slowed gastric emptying and decreased the maximum concentration (C(max)) and area under the curve (AUC(90 min)) value in a dose-dependent manner. Mosapride (0.2-5 mg/kg) accelerated gastric emptying and increased C(max) value. Mosapride (20 mg/kg) did not accelerate gastric emptying on the (13)C-breath test. Itopride (30 mg/kg, per os) significantly accelerated gastric emptying compared with the vehicle group. In a comparison with the conventional phenol red test, there was a correlation between the C(max) value of breath test and gastric emptying (%) of phenol red tests in treatment with loperamide or mosapride. These results indicate that the (13)C-acetic acid breath test is an accurate, noninvasive, and simple method for monitoring gastric emptying in mice. This method is useful to assess the effect of drugs and gut function pharmacologically.
van den Boer, Cindy; Muller, Sara H; Vincent, Andrew D; Züchner, Klaus; van den Brekel, Michiel W M; Hilgers, Frans J M
2013-09-01
Breathing through a tracheostomy results in insufficient warming and humidification of inspired air. This loss of air-conditioning can be partially compensated for with the application of a heat and moisture exchanger (HME) over the tracheostomy. In vitro (International Organization for Standardization [ISO] standard 9360-2:2001) and in vivo measurements of the effects of an HME are complex and technically challenging. The aim of this study was to develop a simple method to measure the ex vivo HME performance comparable with previous in vitro and in vivo results. HMEs were weighed at the end of inspiration and at the end of expiration at different breathing volumes. Four HMEs (Atos Medical, Hörby, Sweden) with known in vivo humidity and in vitro water loss values were tested. The associations between weight change, volume, and absolute humidity were determined using both linear and non-linear mixed effects models. The rating between the 4 HMEs by weighing correlated with previous intra-tracheal measurements (R(2) = 0.98), and the ISO standard (R(2) = 0.77). Assessment of the weight change between end of inhalation and end of exhalation is a valid and simple method of measuring the water exchange performance of an HME.
Technical clarity in inter-agency negotiations: Lessons from four hydropower projects
Burkardt, Nina; Lamb, Berton Lee; Taylor, Jonathan G.; Waddle, Terry J.
1995-01-01
We investigated the effect of technical clarity on success in multi-party negotiations in the Federal Energy Regulatory Commission (FERC) licensing process. Technical clarity is the shared understanding of dimensions such as the geographic extent of the project, range of flows to be considered, important species and life stages, and variety of water uses considered. The results of four hydropower licensing consultations are reported. Key participants were interviewed to ascertain the level of technical clarity present during the consultations and the degree to which the consultations were successful. Technical clarity appears to be a prerequisite for successful outcomes. Factors that enhance technical clarity include simple project design, new rather than existing projects, precise definition of issues, a sense of urgency to reach agreement, a sense of fairness among participants, and consistency in participation. Negotiators should not neglect the critical pre-negotiation steps of defining technical issues and determining appropriate studies, deciding how to interpret studies, and agreeing on responses to study results.
The S-Matrix and Acoustic Signal Structure in Simple and Compound Waveguides.
1982-12-01
RD-A125 583 THE S-MATRIX AND ACOUSTIC SIGNAL STRUCTURE IN SIMPLE- L/1 AND COMPOUND WAVEGUIDES(U) UTAH UNIV SALT LAKE CITY DEPT OF MATHEMATICS C H...WILCOX DEC 82 TSR-45 UNCLASSIFIED N6@8i4-76-C-8276 F/G 12/1 NL IEINEIIIIIIEIhllhlllllllIflllllflflflflflEN L-- U5-12 III,2,0 III.J --IL.,5 MICROCOP ...RESLUIO TETCHRNATIONA BUREA OF 20NADS16 THE S-MATRIX AND ACOUSTIC SIGNAL STRUCTURE IN SIMPLE AND COMPOUND WAVEGUIDES C. H. Wilcox Technical Simmary Report
New approaches to some methodological problems of meteor science
NASA Technical Reports Server (NTRS)
Meisel, David D.
1987-01-01
Several low cost approaches to continuous radioscatter monitoring of the incoming meteor flux are described. Preliminary experiments were attempted using standard time frequency stations WWVH and CHU (on frequencies near 15 MHz) during nighttime hours. Around-the-clock monitoring using the international standard aeronautical beacon frequency of 75 MHz was also attempted. The techniques are simple and can be managed routinely by amateur astronomers with relatively little technical expertise. Time series analysis can now be performed using relatively inexpensive microcomputers. Several algorithmic approaches to the analysis of meteor rates are discussed. Methods of obtaining optimal filter predictions of future meteor flux are also discussed.
Statistical science: a grammar for research.
Cox, David R
2017-06-01
I greatly appreciate the invitation to give this lecture with its century long history. The title is a warning that the lecture is rather discursive and not highly focused and technical. The theme is simple. That statistical thinking provides a unifying set of general ideas and specific methods relevant whenever appreciable natural variation is present. To be most fruitful these ideas should merge seamlessly with subject-matter considerations. By contrast, there is sometimes a temptation to regard formal statistical analysis as a ritual to be added after the serious work has been done, a ritual to satisfy convention, referees, and regulatory agencies. I want implicitly to refute that idea.
Environmental Detection of Clandestine Nuclear Weapon Programs
NASA Astrophysics Data System (ADS)
Kemp, R. Scott
2016-06-01
Environmental sensing of nuclear activities has the potential to detect nuclear weapon programs at early stages, deter nuclear proliferation, and help verify nuclear accords. However, no robust system of detection has been deployed to date. This can be variously attributed to high costs, technical limitations in detector technology, simple countermeasures, and uncertainty about the magnitude or behavior of potential signals. In this article, current capabilities and promising opportunities are reviewed. Systematic research in a variety of areas could improve prospects for detecting covert nuclear programs, although the potential for countermeasures suggests long-term verification of nuclear agreements will need to rely on methods other than environmental sensing.
Qualitative Beam Profiling of Light Curing Units for Resin Based Composites.
Haenel, Thomas; Hausnerová, Berenika; Steinhaus, Johannes; Moeginger, Ing Bernhard
2016-12-01
This study investigates two technically simple methods to determine the irradiance distribution of light curing units that governs the performance of a visible-light curing resin-based composites. Insufficient light irradiation leads to under-cured composites with poor mechanical properties and elution of residual monomers. The unknown irradiance distribution and its effect on the final restoration are the main critical issues requiring highly sophisticated experimental equipment. The study shows that irradiance distributions of LCUs can easily be determined qualitatively with generally available equipment. This significantly helps dentists in practices to be informed about the homogeneity of the curing lights. Copyright© 2016 Dennis Barber Ltd.
A hybrid microfluidic-vacuum device for direct interfacing with conventional cell culture methods
Chung, Bong Geun; Park, Jeong Won; Hu, Jia Sheng; Huang, Carlos; Monuki, Edwin S; Jeon, Noo Li
2007-01-01
Background Microfluidics is an enabling technology with a number of advantages over traditional tissue culture methods when precise control of cellular microenvironment is required. However, there are a number of practical and technical limitations that impede wider implementation in routine biomedical research. Specialized equipment and protocols required for fabrication and setting up microfluidic experiments present hurdles for routine use by most biology laboratories. Results We have developed and validated a novel microfluidic device that can directly interface with conventional tissue culture methods to generate and maintain controlled soluble environments in a Petri dish. It incorporates separate sets of fluidic channels and vacuum networks on a single device that allows reversible application of microfluidic gradients onto wet cell culture surfaces. Stable, precise concentration gradients of soluble factors were generated using simple microfluidic channels that were attached to a perfusion system. We successfully demonstrated real-time optical live/dead cell imaging of neural stem cells exposed to a hydrogen peroxide gradient and chemotaxis of metastatic breast cancer cells in a growth factor gradient. Conclusion This paper describes the design and application of a versatile microfluidic device that can directly interface with conventional cell culture methods. This platform provides a simple yet versatile tool for incorporating the advantages of a microfluidic approach to biological assays without changing established tissue culture protocols. PMID:17883868
Anderson, Beth M.; Stevens, Michael C.; Glahn, David C.; Assaf, Michal; Pearlson, Godfrey D.
2013-01-01
We present a modular, high performance, open-source database system that incorporates popular neuroimaging database features with novel peer-to-peer sharing, and a simple installation. An increasing number of imaging centers have created a massive amount of neuroimaging data since fMRI became popular more than 20 years ago, with much of that data unshared. The Neuroinformatics Database (NiDB) provides a stable platform to store and manipulate neuroimaging data and addresses several of the impediments to data sharing presented by the INCF Task Force on Neuroimaging Datasharing, including 1) motivation to share data, 2) technical issues, and 3) standards development. NiDB solves these problems by 1) minimizing PHI use, providing a cost effective simple locally stored platform, 2) storing and associating all data (including genome) with a subject and creating a peer-to-peer sharing model, and 3) defining a sample, normalized definition of a data storage structure that is used in NiDB. NiDB not only simplifies the local storage and analysis of neuroimaging data, but also enables simple sharing of raw data and analysis methods, which may encourage further sharing. PMID:23912507
A simple, less invasive stripper micropipetter-based technique for day 3 embryo biopsy.
Cedillo, Luciano; Ocampo-Bárcenas, Azucena; Maldonado, Israel; Valdez-Morales, Francisco J; Camargo, Felipe; López-Bayghen, Esther
2016-01-01
Preimplantation genetic screening (PGS) is an important procedure for in vitro fertilization (IVF). A key step of PGS, blastomere removal, is abundant with many technical issues. The aim of this study was to compare a more simple procedure based on the Stipper Micropipetter, named S-biopsy, to the conventional aspiration method. On Day 3, 368 high-quality embryos (>7 cells on Day3 with <10% fragmentation) were collected from 38 women. For each patient, their embryos were equally separated between the conventional method ( n = 188) and S-biopsy method ( n = 180). The conventional method was performed using a standardized protocol. For the S-biopsy method, a laser was used to remove a significantly smaller portion of the zona pellucida. Afterwards, the complete embryo was aspirated with a Stripper Micropipetter, forcing the removal of the blastomere. Selected blastomeres went to PGS using CGH microarrays. Embryo integrity and blastocyst formation were assessed on Day 5. Differences between groups were assessed by either the Mann-Whitney test or Fisher Exact test. Both methods resulted in the removal of only one blastomere. The S-biopsy and the conventional method did not differ in terms of affecting embryo integrity (95.0% vs. 95.7%) or blastocyst formation (72.7% vs. 70.7%). PGS analysis indicated that aneuploidy rate were similar between the two methods (63.1% vs. 65.2%). However, the time required to perform the S-biopsy method (179.2 ± 17.5 s) was significantly shorter (5-fold) than the conventional method. The S-biopsy method is comparable to the conventional method that is used to remove a blastomere for PGS, but requires less time. Furthermore, due to the simplicity of the S-biopsy technique, this method is more ideal for IVF laboratories.
Euthanasia Method for Mice in Rapid Time-Course Pulmonary Pharmacokinetic Studies
Schoell, Adam R; Heyde, Bruce R; Weir, Dana E; Chiang, Po-Chang; Hu, Yiding; Tung, David K
2009-01-01
To develop a means of euthanasia to support rapid time-course pharmacokinetic studies in mice, we compared retroorbital and intravenous lateral tail vein injection of ketamine–xylazine with regard to preparation time, utility, tissue distribution, and time to onset of euthanasia. Tissue distribution and time to onset of euthanasia did not differ between administration methods. However, retroorbital injection could be performed more rapidly than intravenous injection and was considered to be a technically simple and superior alternative for mouse euthanasia. Retroorbital ketamine–xylazine, CO2 gas, and intraperitoneal pentobarbital then were compared as euthanasia agents in a rapid time-point pharmacokinetic study. Retroorbital ketamine–xylazine was the most efficient and consistent of the 3 methods, with an average time to death of approximately 5 s after injection. In addition, euthanasia by retroorbital ketamine–xylazine enabled accurate sample collection at closely spaced time points and satisfied established criteria for acceptable euthanasia technique. PMID:19807971
Euthanasia method for mice in rapid time-course pulmonary pharmacokinetic studies.
Schoell, Adam R; Heyde, Bruce R; Weir, Dana E; Chiang, Po-Chang; Hu, Yiding; Tung, David K
2009-09-01
To develop a means of euthanasia to support rapid time-course pharmacokinetic studies in mice, we compared retroorbital and intravenous lateral tail vein injection of ketamine-xylazine with regard to preparation time, utility, tissue distribution, and time to onset of euthanasia. Tissue distribution and time to onset of euthanasia did not differ between administration methods. However, retroorbital injection could be performed more rapidly than intravenous injection and was considered to be a technically simple and superior alternative for mouse euthanasia. Retroorbital ketamine-xylazine, CO(2) gas, and intraperitoneal pentobarbital then were compared as euthanasia agents in a rapid time-point pharmacokinetic study. Retroorbital ketamine-xylazine was the most efficient and consistent of the 3 methods, with an average time to death of approximately 5 s after injection. In addition, euthanasia by retroorbital ketamine-xylazine enabled accurate sample collection at closely spaced time points and satisfied established criteria for acceptable euthanasia technique.
Cappabianca, P; Cavallo, L M; Mariniello, G; de Divitiis, O; Romero, A D; de Divitiis, E
2001-08-01
To describe a simple method of sellar reconstruction after endoscopic endonasal transsphenoidal surgery that will allow rapid watertight closure of the sellar floor. A bent sheet of a polyester-silicone dural substitute, fashioned for this purpose with scissors, is introduced into the sella after removal of the lesion. Because of the consistency of the sheet, it opens spontaneously and becomes stuck. Autologous fat tissue or gelatin foam is positioned thereafter, followed by another layer of the dural substitute; a film of fibrin glue completes the sealing. Fifteen patients underwent this method and no postoperative cerebrospinal leak or other complication was experienced. This easy method of sellar reconstruction represents an effective and fast possibility to perform the final step of the endoscopic transsphenoidal procedure, which otherwise may cause maneuverability problems in the limited space of one nostril.
A simple method for the construction of small format tissue arrays
Hidalgo, A; Piña, P; Guerrero, G; Lazos, M; Salcedo, M
2003-01-01
Tissue arrays can evaluate molecular targets in high numbers of samples in parallel. Array construction presents technical difficulties and tissue arrayers are expensive, particularly for small and medium sized laboratories. This report describes a method for the construction of 36 sample arrays using widely available materials. A blunted 16 gauge needle for bone marrow aspiration was used to extract paraffin wax cylinders and manually define a 6 × 6 matrix on a blank paraffin wax block. Tissue cores from 36 paraffin wax embedded premalignant lesions and invasive cervical carcinomas were injected into the matrix using a 14 gauge needle. This tissue array was sectioned using a standard microtome and used for the immunodetection of CD44 variant 9 and interleukin 18 with satisfactory results. This method can be applied in any laboratory, without the need of specialised equipment, offering a good alternative for the wider application of tissue arrays. PMID:12560397
Development of a simplified and convenient assay for cell-mediated immunity to the mumps virus.
Otani, Naruhito; Shima, Masayuki; Nakajima, Kazuhiko; Takesue, Yoshio; Okuno, Toshiomi
2014-09-01
Because methods for measuring cell-mediated immunity (CMI) to the mumps virus are expensive, time-consuming, and technically demanding, the role of CMI in mumps virus infection remains unclear. To address this issue, we report here the development of a simplified method for measuring mumps virus-specific CMI that is suitable for use in diverse laboratory and clinical settings. A mumps vaccine was cultured with whole blood, and interferon (IFN)-γ released into the culture supernatant was measured using an enzyme-linked immunosorbent assay. IFN-γ production in blood from vaccinated subjects markedly increased in response to the vaccine and decreased before the antibody titer decreased in some cases, suggesting that this assay may be used as a simple surrogate method for measuring CMI specific for the mumps virus. Copyright © 2014 Elsevier B.V. All rights reserved.
Gallo-Oller, Gabriel; Ordoñez, Raquel; Dotor, Javier
2018-06-01
Since its first description, Western blot has been widely used in molecular labs. It constitutes a multistep method that allows the detection and/or quantification of proteins from simple to complex protein mixtures. Western blot quantification method constitutes a critical step in order to obtain accurate and reproducible results. Due to the technical knowledge required for densitometry analysis together with the resources availability, standard office scanners are often used for the imaging acquisition of developed Western blot films. Furthermore, the use of semi-quantitative software as ImageJ (Java-based image-processing and analysis software) is clearly increasing in different scientific fields. In this work, we describe the use of office scanner coupled with the ImageJ software together with a new image background subtraction method for accurate Western blot quantification. The proposed method represents an affordable, accurate and reproducible approximation that could be used in the presence of limited resources availability. Copyright © 2018 Elsevier B.V. All rights reserved.
SIMPLE GREEN® (Dual listing for 2013 reformulation)
Technical product bulletin: this surface washing agent is suitable for use in oil spill cleanups in freshwater, estuarine, and marine environments at all temperatures, on both porous and non-porous surfaces.
Gastroschisis Simulation Model: Pre-surgical Management Technical Report.
Rosen, Orna; Angert, Robert M
2017-03-22
This technical report describes the creation of a gastroschisis model for a newborn. This is a simple, low-cost task trainer that provides the opportunity for Neonatology providers, including fellows, residents, nurse practitioners, physician assistants, and nurses, to practice the management of a baby with gastroschisis after birth and prior to surgery. Included is a suggested checklist with which the model can be employed. The details can be modified to suit different learning objectives.
Reliability Standards of Complex Engineering Systems
NASA Astrophysics Data System (ADS)
Galperin, E. M.; Zayko, V. A.; Gorshkalev, P. A.
2017-11-01
Production and manufacture play an important role in today’s modern society. Industrial production is nowadays characterized by increased and complex communications between its parts. The problem of preventing accidents in a large industrial enterprise becomes especially relevant. In these circumstances, the reliability of enterprise functioning is of particular importance. Potential damage caused by an accident at such enterprise may lead to substantial material losses and, in some cases, can even cause a loss of human lives. That is why industrial enterprise functioning reliability is immensely important. In terms of their reliability, industrial facilities (objects) are divided into simple and complex. Simple objects are characterized by only two conditions: operable and non-operable. A complex object exists in more than two conditions. The main characteristic here is the stability of its operation. This paper develops the reliability indicator combining the set theory methodology and a state space method. Both are widely used to analyze dynamically developing probability processes. The research also introduces a set of reliability indicators for complex technical systems.
ERIC Educational Resources Information Center
Birk, James P., Ed.
1989-01-01
Presented is a simple laboratory set-up for teaching microprocessor-controlled data acquisition as a part of an instrumental analysis course. Discussed are the experimental set-up, experimental procedures, and technical considerations for this technique. (CW)
Green's Functions in Space and Time.
ERIC Educational Resources Information Center
Rowe, E. G. Peter
1979-01-01
Gives a sketch of some topics in distribution theory that is technically simple, yet provides techniques for handling the partial differential equations satisfied by the most important Green's functions in physics. (Author/GA)
Honeywell Technical Order Transfer Tests.
1987-06-12
of simple corrections, a reasonable reproduction of the original could be generated. The quality was not good enough for a production environment. Lack of automated quality control (AQC) tools could account for the errors.
A simple video-based timing system for on-ice team testing in ice hockey: a technical report.
Larson, David P; Noonan, Benjamin C
2014-09-01
The purpose of this study was to describe and evaluate a newly developed on-ice timing system for team evaluation in the sport of ice hockey. We hypothesized that this new, simple, inexpensive, timing system would prove to be highly accurate and reliable. Six adult subjects (age 30.4 ± 6.2 years) performed on ice tests of acceleration and conditioning. The performance times of the subjects were recorded using a handheld stopwatch, photocell, and high-speed (240 frames per second) video. These results were then compared to allow for accuracy calculations of the stopwatch and video as compared with filtered photocell timing that was used as the "gold standard." Accuracy was evaluated using maximal differences, typical error/coefficient of variation (CV), and intraclass correlation coefficients (ICCs) between the timing methods. The reliability of the video method was evaluated using the same variables in a test-retest analysis both within and between evaluators. The video timing method proved to be both highly accurate (ICC: 0.96-0.99 and CV: 0.1-0.6% as compared with the photocell method) and reliable (ICC and CV within and between evaluators: 0.99 and 0.08%, respectively). This video-based timing method provides a very rapid means of collecting a high volume of very accurate and reliable on-ice measures of skating speed and conditioning, and can easily be adapted to other testing surfaces and parameters.
Beck, P H; Conklin, H B
1975-01-01
We analyzed the records of 77 cases of loop colostomy closure in Vietnam War Casualties. All records were complete from the date of injury to discharge following colostomy closure. Simple of the loop colostomy was performed in 44 patients and resection of the stoma and reanastomosis of bowel segments was performed in 33 patients. Average operating time for simple closure of the loop was 70 minutes compared to 115 minutes for resection and anastomosis. Nasogastric suction was used less frequently and for a shorter time with simple loop closure. The total postoperative complication rate was 9% with simple loop closure as compared to 24% for resection and anastomosis. Simple closure of the loop described in this report is technically easier and as safe as resection of the stoma and reanastomosis. Images Fig. 1. PMID:1094967
PVWatts Version 1 Technical Reference
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dobos, A. P.
2013-10-01
The NREL PVWatts(TM) calculator is a web application developed by the National Renewable Energy Laboratory (NREL) that estimates the electricity production of a grid-connected photovoltaic system based on a few simple inputs. PVWatts combines a number of sub-models to predict overall system performance, and makes several hidden assumptions about performance parameters. This technical reference details the individual sub-models, documents assumptions and hidden parameters, and explains the sequence of calculations that yield the final system performance estimation.
Gastroschisis Simulation Model: Pre-surgical Management Technical Report
Angert, Robert M
2017-01-01
This technical report describes the creation of a gastroschisis model for a newborn. This is a simple, low-cost task trainer that provides the opportunity for Neonatology providers, including fellows, residents, nurse practitioners, physician assistants, and nurses, to practice the management of a baby with gastroschisis after birth and prior to surgery. Included is a suggested checklist with which the model can be employed. The details can be modified to suit different learning objectives. PMID:28439484
Technical Report 1205: A Simple Probabilistic Combat Model
2016-07-08
This page intentionally left blank. 1. INTRODUCTION The Lanchester combat model1 is a simple way to assess the effects of quantity and quality...model. For the random case, assume R red weapons are allocated to B blue weapons randomly. We are interested in the distribution of weapons assigned...the initial condition is very close to the break even line. What is more interesting is that the probability density tends to concentrate at either a
[Determination of trace gallium by graphite furnace atomic absorption spectrometry in urine].
Zhou, L Z; Fu, S; Gao, S Q; He, G W
2016-06-20
To establish a method for determination trace gallium in urine by graphite furnace atomic absorption spectrometry (GFAAS). The ammonium dihydrogen phosphate was matrix modifier. The temperature effect about pyrolysis (Tpyr) and atomization temperature were optimized for determination of trace gallium. The method of technical standard about within-run, between-run and recoveries of standard were optimized. The method showed a linear relationship within the range of 0.20~80.00 μg/L (r=0.998). The within-run and between-run relative standard deviations (RSD) of repetitive measurement at 5.0, 10.0, 20.0 μg/L concentration levels were 2.1%~5.5% and 2.3%~3.0%. The detection limit was 0.06 μg/L. The recoveries of gallium were 98.2%~101.1%. This method is simple, low detection limit, accurate, reliable and reproducible. It has been applied for determination of trace gallium in urine samples those who need occupation health examination or poisoning diagnosis.
Authorship attribution based on Life-Like Network Automata.
Machicao, Jeaneth; Corrêa, Edilson A; Miranda, Gisele H B; Amancio, Diego R; Bruno, Odemir M
2018-01-01
The authorship attribution is a problem of considerable practical and technical interest. Several methods have been designed to infer the authorship of disputed documents in multiple contexts. While traditional statistical methods based solely on word counts and related measurements have provided a simple, yet effective solution in particular cases; they are prone to manipulation. Recently, texts have been successfully modeled as networks, where words are represented by nodes linked according to textual similarity measurements. Such models are useful to identify informative topological patterns for the authorship recognition task. However, there is no consensus on which measurements should be used. Thus, we proposed a novel method to characterize text networks, by considering both topological and dynamical aspects of networks. Using concepts and methods from cellular automata theory, we devised a strategy to grasp informative spatio-temporal patterns from this model. Our experiments revealed an outperformance over structural analysis relying only on topological measurements, such as clustering coefficient, betweenness and shortest paths. The optimized results obtained here pave the way for a better characterization of textual networks.
Aldana Marcos, H J; Ferrari, C C; Benitez, I; Affanni, J M
1996-12-01
This paper reports the standardization of methods used for processing and embedding various vertebrate brains of different size in paraffin. Other technical details developed for avoiding frequent difficulties arising during laboratory routine are also reported. Some modifications of the Nissl and Klüver-Barrera staining methods are proposed. These modifications include: 1) a Nissl stain solution with a rapid and efficient action with easier differentiation; 2) the use of a cheap microwave oven for the Klüver-Barrera stain. These procedures have the advantage of permitting Nissl and Klüver-Barrera staining of nervous tissue in about five and fifteen minutes respectively. The proposed procedures have been tested in brains obtained from fish, amphibians, reptiles and mammals of different body sizes. They are the result of our long experience in preparing slides for comparative studies. Serial sections of excellent quality were regularly obtained in all the specimens studied. These standardized methods, being simple and quick, are recommended for routine use in neurobiological laboratories.
Methodological dimensions of transcranial brain stimulation with the electrical current in human.
Rostami, Maryam; Golesorkhi, Mehrshad; Ekhtiari, Hamed
2013-01-01
Transcranial current stimulation (TCS) is a neuromodulation method in which the patient is exposed to a mild electric current (direct or alternating) at 1-2 mA, resulting in an increase or a decrease in the brain excitability. This modification in neural activities can be used as a method for functional human brain mapping with causal inferences. This method might also facilitate the treatments of many neuropsychiatric disorders based on its inexpensive, simple, safe, noninvasive, painless, semi-focal excitatory and inhibitory effects. Given this, a comparison amongst different brain stimulation modalities has been made to determine the potential advantages of the TCS method. In addition, considerable methodological details on using TCS in basic and clinical neuroscience studies in human subjects have been introduced. Technical characteristics of TCS devices and their related accessories with regard to safety concerns have also been well articulated. Finally, some TCS application opportunities have been emphasized, including its potential use in the near future.
Discrimination of wine lactic acid bacteria by Raman spectroscopy.
Rodriguez, Susan B; Thornton, Mark A; Thornton, Roy J
2017-08-01
Species of Lactobacillus, Pediococcus, Oenococcus, and Leuconostoc play an important role in winemaking, as either inoculants or contaminants. The metabolic products of these lactic acid bacteria have considerable effects on the flavor, aroma, and texture of a wine. However, analysis of a wine's microflora, especially the bacteria, is rarely done unless spoilage becomes evident, and identification at the species or strain level is uncommon as the methods required are technically difficult and expensive. In this work, we used Raman spectral fingerprints to discriminate 19 strains of Lactobacillus, Pediococcus, and Oenococcus. Species of Lactobacillus and Pediococcus and strains of O. oeni and P. damnosus were classified with high sensitivity: 86-90 and 84-85%, respectively. Our results demonstrate that a simple, inexpensive method utilizing Raman spectroscopy can be used to accurately identify lactic acid bacteria isolated from wine.
Management of obstructed balloon catheters.
Browning, G G; Barr, L; Horsburgh, A G
1984-01-01
Failure of a balloon catheter to deflate is not uncommon and prevents its removal. Methods of overcoming the problem include traction, bursting the balloon by overinflation, dissolving it with solvents, puncturing it percutaneously with a needle, or puncturing it with a wire stylet passed through the catheter. All except the last technique have major disadvantages and are of questionable safety. Transcatheter puncture of the balloon was used in 16 patients to remove obstructed balloon catheters without any technical difficulty, distress to the patient, or complication. The procedure is safe, simple, and does not require an anaesthetic. If necessary it could be performed safely by nursing or paramedical staff without the patient having to be admitted to hospital. It is the method of choice for the management of this problem. Images FIG 1 FIG 2 FIG 3 FIG 4 PMID:6428691
Hostein, J; Capony, P; Busquet, G; Bost, R; Fournet, J
1985-04-01
For gastric emptying studies of a solid-liquid meal by the scintigraphic method, a valid isotope labeling method for each phase of the meal must be obtained. The aim of this study was to validate a simple chicken liver labeling method in normal subjects by multipuncture technic with 99mtechnetium. Labeling according to Meyer's method was chosen as a reference. Simultaneously, a study of the quality of liquid phase labeling by 111indium was done. The labeling process quality for each phase of the meal was assessed: a) in vitro, after incubation of the meal with human gastric juice (n = 12); b) in vivo, after meal ingestion and sequential collection of gastric contents by aspiration (n = 4). Furthermore, in 8 healthy volunteers, gastric emptying curves of the solid and liquid phases of the meal were determined scintigraphically and compared. Our results showed: a) for the solid phase: a good specificity of the marker, which was assessed in vitro and in vivo, after liver labeling with multipuncture technique (89 p. 100 and 92 p. 100 after 180 min, respectively); b) for the liquid phase: a good specificity of the marker in vitro and a poor specificity in vivo (82 p. 100 and 27 p. 100 after 180 min, respectively); c) similar half-gastric emptying times and cumulative percentages for the solid and liquid phases with both liver labeling methods. In conclusion, the multipuncture technique for chicken liver labeling may be used for gastric emptying studies in humans.
Hiradfar, Mehran; Shojaeian, Reza; Zabolinejad, Nona; Gharavifard, Mohammad; Sabzevari, Alireza; Joodi, Marjan; Yal, Nazila; Saeedi Sharifabad, Parisa; Hajian, Sara; Nazarzadeh, Reza; Lotfinejad, Nasim
2014-03-01
Giving the ever-rising trend of pediatric minimally invasive surgery besides early neonatal surgical interventions, intestinal anastomosis turns out to be a time consuming stage due to several anatomical as well as technical difficulties. A perfect bowel anastomosis method should be easy, rapid, safe and reliable in creation of bowel continuity with minimal tissue damage. In this light, sutureless anastomotic methods have been introduced, using compression based anastomosis with biofragmentable rings or powerful magnets. Accordingly, this experimental animal model study has evaluated the result of an easy, rapid intestinal sutureless anastomotic technique via simple tying over an intraluminal ring, in comparison with conventional handsewn bowel anastomosis. Thirty Wistar-Albino male rats were enrolled and small bowel was transected via a midline laparotomy. A grooved plastic ring was inserted into the ileal lumen and both intestinal cutting ends were fixed over the ring with a simple tie in the first group. On the other hand, enteroenterostomy was performed by the conventional method of handsewn anastomosis in the second group. After 14 days, rats were sacrificed to evaluate for intraperitoneal adhesion and abscess formation in addition to other evidences of anastomotic leakage. Furthermore, the anastomotic site integrity, tensile strength and healing stage were assessed microscopically. The mean operative time and intraoperative bleeding in the tie over ring group were significantly less than those in the handsewn anastomosis group. Anastomotic stricture was more common in the conventional anastomosis group while the anastomotic tensile strength was significantly higher in the tie over ring group. Histopathological healing parameters and final healing score were almost similar in both groups but mean inflammatory cell infiltration in handsewn anastomosis was significantly higher. "Tie over ring" is a simple method of anastomosis that is feasible, fast, safe and functionally effective for bowel reconstruction in animal models that could be reconsidered in human bowel anastomosis. © 2014.
Sensors and filters based on nano- and microchannel membranes for biomedical technologies
NASA Astrophysics Data System (ADS)
Romanov, S. I.; Pyshnyi, D. V.; Laktionov, P. P.
2012-02-01
A new technology is presented in a concise form which enables the silicon membranes to be produced over a wide range of channel dimensions from a few nanometers to tens of micrometers. There is good reason to believe that this method based on rather simple technical processing is competitive with other technologies for fabricating nanofluidic analysis systems. Some of the completed developments involving microchannel membranes, namely, the optical DNA-sensor and the human cell separation system are demonstrated without going into details. The other applications of micro- and nanochannel membranes, namely, the electrical sensor and electrokinetic filters for detecting and separating liquids and biomolecules are shown with the first results and are in progress.
Plasma RNA integrity analysis: methodology and validation.
Wong, Blenda C K; Lo, Y M Dennis
2006-09-01
The detection of cell-free RNA in plasma and serum of human subjects has found increasing applications in the field of medical diagnostics. However, many questions regarding the biology of circulating RNA remain to be addressed. One issue concerns the molecular nature of these circulating RNA species. We have recently developed a simple and quantitative method to investigate the integrity of plasma RNA. Our results have suggested that cell-free RNA in plasma is generally present as fragmented molecules instead of intact transcripts, with a predominance of 5' fragments. In this article, we summarize the basic principles in the experimental design for plasma RNA integrity analysis and highlight some of the important technical considerations for this type of investigation.
Regression dilution bias: tools for correction methods and sample size calculation.
Berglund, Lars
2012-08-01
Random errors in measurement of a risk factor will introduce downward bias of an estimated association to a disease or a disease marker. This phenomenon is called regression dilution bias. A bias correction may be made with data from a validity study or a reliability study. In this article we give a non-technical description of designs of reliability studies with emphasis on selection of individuals for a repeated measurement, assumptions of measurement error models, and correction methods for the slope in a simple linear regression model where the dependent variable is a continuous variable. Also, we describe situations where correction for regression dilution bias is not appropriate. The methods are illustrated with the association between insulin sensitivity measured with the euglycaemic insulin clamp technique and fasting insulin, where measurement of the latter variable carries noticeable random error. We provide software tools for estimation of a corrected slope in a simple linear regression model assuming data for a continuous dependent variable and a continuous risk factor from a main study and an additional measurement of the risk factor in a reliability study. Also, we supply programs for estimation of the number of individuals needed in the reliability study and for choice of its design. Our conclusion is that correction for regression dilution bias is seldom applied in epidemiological studies. This may cause important effects of risk factors with large measurement errors to be neglected.
Transportation-markings general table of contents with index
DOT National Transportation Integrated Search
2008-01-01
The T-M process outlined in these studies describes and classifies safety aids that assist operators of modes of transportation that process also includes technical and historical perspectives. However; a simple describing and classifying of safety a...
What Was Expected from the Michelson-Morley Experiment--A Simple Classroom Demonstration.
ERIC Educational Resources Information Center
Babovic, V. M.; And Others
1989-01-01
Describes the layout, working principle, and uses of an ultrasonic interferometer for demonstrating the impact of the motion of the medium upon wave propagation. Suggests some technical improvements of the interferometer. (YP)
Animal models for studying transport across the blood-brain barrier.
Bonate, P L
1995-01-01
There are many reasons for wishing to determine the rate of uptake of a drug from blood into brain parenchyma. However, when faced with doing so for the first time, choosing a method can be a formidable task. There are at least 7 methods from which to choose: indicator dilution, brain uptake index, microdialysis, external registration, PET scanning, in situ perfusion, and compartmental modeling. Each method has advantages and disadvantages. Some methods require very little equipment while others require equipment that can cost millions of dollars. Some methods require very little technical experience whereas others require complex surgical manipulation. The mathematics alone for the various methods range from simple algebra to complex integral calculus and differential equations. Like most things in science, as the complexity of the technique increases, so does the quantity of information it provides. This review is meant to serve as a starting point for the researcher who wishes to study transport and uptake across the blood-brain barrier in animal models. An overview of the mathematical theory, as well as an introduction to the techniques, is presented.
Said, Halima M; Krishnamani, Keshav; Omar, Shaheed V; Dreyer, Andries W; Sansom, Bianca; Fallows, Dorothy; Ismail, Nazir A
2016-10-01
The manual IS6110-based restriction fragment length polymorphism (RFLP) typing method is highly discriminatory; however, it is laborious and technically demanding, and data exchange remains a challenge. In an effort to improve IS6110-based RFLP to make it a faster format, DuPont Molecular Diagnostics recently introduced the IS6110-PvuII kit for semiautomated typing of Mycobacterium tuberculosis using the RiboPrinter microbial characterization system. This study aimed to evaluate the semiautomated RFLP typing against the standard manual method. A total of 112 isolates collected between 2013 and 2014 were included. All isolates were genotyped using manual and semiautomated RFLP typing methods. Clustering rates and discriminatory indexes were compared between methods. The overall performance of semiautomated RFLP compared to manual typing was excellent, with high discriminatory index (0.990 versus 0.995, respectively) and similar numbers of unique profiles (72 versus 74, respectively), numbers of clustered isolates (33 versus 31, respectively), cluster sizes (2 to 6 and 2 to 5 isolates, respectively), and clustering rates (21.9% and 17.1%, respectively). The semiautomated RFLP system is technically simple and significantly faster than the manual RFLP method (8 h versus 5 days). The analysis is fully automated and generates easily manageable databases of standardized fingerprints that can be easily exchanged between laboratories. Based on its high-throughput processing with minimal human effort, the semiautomated RFLP can be a very useful tool as a first-line method for routine typing of M. tuberculosis isolates, especially where Beijing strains are highly prevalent, followed by manual RFLP typing if resolution is not achieved, thereby saving time and labor. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Kobara, Hideki; Mori, Hirohito; Fujihara, Shintaro; Nishiyama, Noriko; Chiyo, Taiga; Yamada, Takayoshi; Fujiwara, Masao; Okano, Keiichi; Suzuki, Yasuyuki; Murota, Masayuki; Ikeda, Yoshitaka; Oryu, Makoto; AboEllail, Mohamed; Masaki, Tsutomu
2017-01-01
AIM To demonstrate the clinical outcomes of a multicenter experience and to suggest guidelines for choosing a suction method. METHODS This retrospective study at 5 medical centers involved 58 consecutive patients undergoing over-the-scope clips (OTSCs) placement. The overall rates of technical success (TSR), clinical success (CSR), complications, and procedure time were analyzed as major outcomes. Subsequently, 56 patients, excluding two cases that used the Anchor device, were divided into two groups: 14 cases of simple suction (SS-group) and 42 cases using the Twin Grasper (TG-group). Secondary evaluation was performed to clarify the predictors of OTSC success. RESULTS The TSR, CSR, complication rate, and median procedure time were 89.7%, 84.5%, 1.8%, and 8 (range 1-36) min, respectively, demonstrating good outcomes. However, significant differences were observed between the two groups in terms of the mean procedure time (5.9 min vs 14.1 min). The CSR of the SS- and TG-groups among cases with a maximum defect size ≤ 10 mm and immediate or acute refractory bleeding was 100%, which suggests that SS is a better method than TG in terms of time efficacy. The CSR in the SS-group (78.6%), despite the technical success of the SS method (TSR, 100%), tended to decrease due to delayed leakage compared to that in the TG-group (TSR, CSR; 88.1%), indicating that TG may be desirable for leaks and fistulae with defects of the entire layer. CONCLUSION OTSC system is a safe and effective therapeutic option for gastrointestinal defects. Individualized selection of the suction method based on particular clinical conditions may contribute to the improvement of OTSC success. PMID:28321166
NASA Astrophysics Data System (ADS)
Vidal, Borja; Lafuente, Juan A.
2016-03-01
A simple technique to avoid color limitations in image capture systems based on chroma key video composition using retroreflective screens and light-emitting diodes (LED) rings is proposed and demonstrated. The combination of an asynchronous temporal modulation onto the background illumination and simple image processing removes the usual restrictions on foreground colors in the scene. The technique removes technical constraints in stage composition, allowing its design to be purely based on artistic grounds. Since it only requires adding a very simple electronic circuit to widely used chroma keying hardware based on retroreflective screens, the technique is easily applicable to TV and filming studios.
Gutmann, Torsten; Ratajczyk, Tomasz; Dillenberger, Sonja; Xu, Yeping; Grünberg, Anna; Breitzke, Hergen; Bommerich, Ute; Trantzschel, Thomas; Bernarding, Johannes; Buntkowsky, Gerd
2011-09-01
It is shown that the para-hydrogen induced polarization (PHIP) phenomenon in homogenous solution containing the substrate styrene is also observable employing simple inorganic systems of the form MCl(3)·xH(2)O (M=Rh, Ir) as catalyst. Such observation confirms that already very simple metal complexes enable the creation of PHIP signal enhancement in solution. This opens up new pathways to increase the sensitivity of NMR and MRT by PHIP enhancement using cost-effective catalysts and will be essential for further mechanistic studies of simple transition metal systems. Copyright © 2011 Elsevier Inc. All rights reserved.
Educational Experiences of Embry-Riddle Students through NASA Research Collaboration
NASA Technical Reports Server (NTRS)
Schlee, Keith; Chatman, Yadira; Ristow, James; Gangadharan, Sathya; Sudermann, James; Walker, Charles
2007-01-01
NASA's educational programs benefit students while increasing the overall productivity of the organization. The NASA Graduate Student Research Program (GSRP) awards fellowships for graduate study leading to both masters and doctoral degrees in several technical fields, while the Cooperative Education program allows undergraduate and graduate students the chance to gain work experience in the field. The Mission Analysis Branch of the Expendable Launch Vehicles Division at NASA Kennedy Space Center has utilized these two programs with students from Embry-Riddle Aeronautical University to conduct research in modeling and developing a parameter estimation method for spacecraft fuel slosh using simple pendulum analogs. Simple pendulum models are used to understand complicated spacecraft fuel slosh behavior. A robust parameter estimation process will help to identiFy the parameters that will predict the response fairly accurately during the initial stages of design. NASA's Cooperative Education Program trains the next wave of new hires while allowing graduate and undergraduate college students to gain valuable "real-world" work experience. It gives NASA a no risk capability to evaluate the true performance of a prospective new hire without relying solely on a paper resume, while providing the students with a greater hiring potential upon graduation, at NASA or elsewhere. In addition, graduate students serve as mentors for undergrad students and provide a unique learning environment. Providing students with a unique opportunity to work on "real-world" aerospace problems ultimately reinforces their problem solving abilities and their communication skills (in terms of interviewing, resume writing, technical writing, presentation, and peer review) that are vital for the workforce to succeed.
3D Reconstruction in the Presence of Glass and Mirrors by Acoustic and Visual Fusion.
Zhang, Yu; Ye, Mao; Manocha, Dinesh; Yang, Ruigang
2017-07-06
We present a practical and inexpensive method to reconstruct 3D scenes that include transparent and mirror objects. Our work is motivated by the need for automatically generating 3D models of interior scenes, which commonly include glass. These large structures are often invisible to cameras. Existing 3D reconstruction methods for transparent objects are usually not applicable in such a room-sized reconstruction setting. Our simple hardware setup augments a regular depth camera with a single ultrasonic sensor, which is able to measure the distance to any object, including transparent surfaces. The key technical challenge is the sparse sampling rate from the acoustic sensor, which only takes one point measurement per frame. To address this challenge, we take advantage of the fact that the large scale glass structures in indoor environments are usually either piece-wise planar or simple parametric surfaces. Based on these assumptions, we have developed a novel sensor fusion algorithm that first segments the (hybrid) depth map into different categories such as opaque/transparent/infinity (e.g., too far to measure) and then updates the depth map based on the segmentation outcome. We validated our algorithms with a number of challenging cases, including multiple panes of glass, mirrors, and even a curved glass cabinet.
Chorioallantoic membrane for in vivo investigation of tissue-engineered construct biocompatibility.
Baiguera, Silvia; Macchiarini, Paolo; Ribatti, Domenico
2012-07-01
In tissue engineering approach, the scaffold plays a key role for a suitable outcome of cell-scaffold interactions and for the success of tissue healing and regeneration. As a consequence, the characterization of scaffold properties and the in vivo evaluation of tissue responses and effects result to be essential in the development of suitable implantable device. Among the in vivo methods, the chick embryo chorioallantoic membrane (CAM) assay represents a rather simple and cost-effective procedure to study the biocompatibility responses of graft materials. CAM is indeed characterized by low experiment costs, simplicity, relative speed in obtaining the expected results, limited ethical concern, no need of high-level technical skill, and the absence of a mature immune system, resulting in an inexpensive, simple, and practical method to evaluate and characterize tissue-engineered constructs. The results till now obtained suggest that CAM assay can be used as a pre-screening assay, before in vivo animal studies, to determine whether the scaffold is liable to cause an adverse reaction and to evaluate its future enhancement of existing materials for tissue engineering. A review of the more recent results related to the use of CAM for in vivo biomaterial property evaluation is herein reported. Copyright © 2012 Wiley Periodicals, Inc.
Estimating population trends with a linear model: Technical comments
Sauer, John R.; Link, William A.; Royle, J. Andrew
2004-01-01
Controversy has sometimes arisen over whether there is a need to accommodate the limitations of survey design in estimating population change from the count data collected in bird surveys. Analyses of surveys such as the North American Breeding Bird Survey (BBS) can be quite complex; it is natural to ask if the complexity is necessary, or whether the statisticians have run amok. Bart et al. (2003) propose a very simple analysis involving nothing more complicated than simple linear regression, and contrast their approach with model-based procedures. We review the assumptions implicit to their proposed method, and document that these assumptions are unlikely to be valid for surveys such as the BBS. One fundamental limitation of a purely design-based approach is the absence of controls for factors that influence detection of birds at survey sites. We show that failure to model observer effects in survey data leads to substantial bias in estimation of population trends from BBS data for the 20 species that Bart et al. (2003) used as the basis of their simulations. Finally, we note that the simulations presented in Bart et al. (2003) do not provide a useful evaluation of their proposed method, nor do they provide a valid comparison to the estimating- equations alternative they consider.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mueller-Wille, Rene, E-mail: rene.mueller-wille@ukr.de; Wohlgemuth, Walter A., E-mail: walter.wohlgemuth@ukr.de; Heiss, Peter, E-mail: peter.heiss@ukr.de
2013-10-15
Purpose: To determine the feasibility and efficacy of transarterial endoleak embolization using the liquid embolic agent ethylene vinyl alcohol copolymer (Onyx). Methods: Over a 7-year period eleven patients (6 women, 5 men; mean age 68 years, range 37-83 years) underwent transarterial embolization of a type II endoleak after endovascular aortic aneurysm repair using the liquid embolic agent Onyx. Two patients (18 %) had a simple type II endoleak with only one artery in communication with the aneurysm sac, whereas 9 patients (82 %) had a complex type II endoleak with multiple communicating vessels. We retrospectively analyzed the technical and clinicalmore » success of transarterial type II endoleak embolization with Onyx. Complete embolization of the nidus was defined as technical success. Embolization was considered clinically successful when volume of the aneurysm sac was stable or decreased on follow-up CT scans. Result: Mean follow-up time was 26.0 (range 6-50) months. Clinical success was achieved in 8 of 11 patients (73 %). Transarterial nidus embolization with Onyx was technically successful in 6 of 11 patients (55 %). In three cases the nidus was embolized without direct catheterization from a more distal access through the network of collateral vessels. Conclusion: Onyx is a favorable embolic agent for transarterial endoleak embolization. To achieve the best clinical results, complete occlusion of the nidus is mandatory.« less
A simple novel device for air sampling by electrokinetic capture
Gordon, Julian; Gandhi, Prasanthi; Shekhawat, Gajendra; ...
2015-12-27
A variety of different sampling devices are currently available to acquire air samples for the study of the microbiome of the air. All have a degree of technical complexity that limits deployment. Here, we evaluate the use of a novel device, which has no technical complexity and is easily deployable. An air-cleaning device powered by electrokinetic propulsion has been adapted to provide a universal method for collecting samples of the aerobiome. Plasma-induced charge in aerosol particles causes propulsion to and capture on a counter-electrode. The flow of ions creates net bulk airflow, with no moving parts. A device and electrodemore » assembly have been re-designed from air-cleaning technology to provide an average air flow of 120 lpm. This compares favorably with current air sampling devices based on physical air pumping. Capture efficiency was determined by comparison with a 0.4 μm polycarbonate reference filter, using fluorescent latex particles in a controlled environment chamber. Performance was compared with the same reference filter method in field studies in three different environments. For 23 common fungal species by quantitative polymerase chain reaction (qPCR), there was 100 % sensitivity and apparent specificity of 87%, with the reference filter taken as “gold standard.” Further, bacterial analysis of 16S RNA by amplicon sequencing showed equivalent community structure captured by the electrokinetic device and the reference filter. Unlike other current air sampling methods, capture of particles is determined by charge and so is not controlled by particle mass. We analyzed particle sizes captured from air, without regard to specific analyte by atomic force microscopy: particles at least as low as 100 nM could be captured from ambient air. This work introduces a very simple plug-and-play device that can sample air at a high-volume flow rate with no moving parts and collect particles down to the sub-micron range. In conclusion, the performance of the device is substantially equivalent to capture by pumping through a filter for microbiome analysis by quantitative PCR and amplicon sequencing.« less
A simple novel device for air sampling by electrokinetic capture
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gordon, Julian; Gandhi, Prasanthi; Shekhawat, Gajendra
A variety of different sampling devices are currently available to acquire air samples for the study of the microbiome of the air. All have a degree of technical complexity that limits deployment. Here, we evaluate the use of a novel device, which has no technical complexity and is easily deployable. An air-cleaning device powered by electrokinetic propulsion has been adapted to provide a universal method for collecting samples of the aerobiome. Plasma-induced charge in aerosol particles causes propulsion to and capture on a counter-electrode. The flow of ions creates net bulk airflow, with no moving parts. A device and electrodemore » assembly have been re-designed from air-cleaning technology to provide an average air flow of 120 lpm. This compares favorably with current air sampling devices based on physical air pumping. Capture efficiency was determined by comparison with a 0.4 μm polycarbonate reference filter, using fluorescent latex particles in a controlled environment chamber. Performance was compared with the same reference filter method in field studies in three different environments. For 23 common fungal species by quantitative polymerase chain reaction (qPCR), there was 100 % sensitivity and apparent specificity of 87%, with the reference filter taken as “gold standard.” Further, bacterial analysis of 16S RNA by amplicon sequencing showed equivalent community structure captured by the electrokinetic device and the reference filter. Unlike other current air sampling methods, capture of particles is determined by charge and so is not controlled by particle mass. We analyzed particle sizes captured from air, without regard to specific analyte by atomic force microscopy: particles at least as low as 100 nM could be captured from ambient air. This work introduces a very simple plug-and-play device that can sample air at a high-volume flow rate with no moving parts and collect particles down to the sub-micron range. In conclusion, the performance of the device is substantially equivalent to capture by pumping through a filter for microbiome analysis by quantitative PCR and amplicon sequencing.« less
A simple novel device for air sampling by electrokinetic capture.
Gordon, Julian; Gandhi, Prasanthi; Shekhawat, Gajendra; Frazier, Angel; Hampton-Marcell, Jarrad; Gilbert, Jack A
2015-12-27
A variety of different sampling devices are currently available to acquire air samples for the study of the microbiome of the air. All have a degree of technical complexity that limits deployment. Here, we evaluate the use of a novel device, which has no technical complexity and is easily deployable. An air-cleaning device powered by electrokinetic propulsion has been adapted to provide a universal method for collecting samples of the aerobiome. Plasma-induced charge in aerosol particles causes propulsion to and capture on a counter-electrode. The flow of ions creates net bulk airflow, with no moving parts. A device and electrode assembly have been re-designed from air-cleaning technology to provide an average air flow of 120 lpm. This compares favorably with current air sampling devices based on physical air pumping. Capture efficiency was determined by comparison with a 0.4 μm polycarbonate reference filter, using fluorescent latex particles in a controlled environment chamber. Performance was compared with the same reference filter method in field studies in three different environments. For 23 common fungal species by quantitative polymerase chain reaction (qPCR), there was 100 % sensitivity and apparent specificity of 87 %, with the reference filter taken as "gold standard." Further, bacterial analysis of 16S RNA by amplicon sequencing showed equivalent community structure captured by the electrokinetic device and the reference filter. Unlike other current air sampling methods, capture of particles is determined by charge and so is not controlled by particle mass. We analyzed particle sizes captured from air, without regard to specific analyte by atomic force microscopy: particles at least as low as 100 nM could be captured from ambient air. This work introduces a very simple plug-and-play device that can sample air at a high-volume flow rate with no moving parts and collect particles down to the sub-micron range. The performance of the device is substantially equivalent to capture by pumping through a filter for microbiome analysis by quantitative PCR and amplicon sequencing.
NASA Astrophysics Data System (ADS)
Hanzer, F.; Marke, T.; Steiger, R.; Strasser, U.
2012-04-01
Tourism and particularly winter tourism is a key factor for the Austrian economy. Judging from currently available climate simulations, the Austrian Alps show a particularly high vulnerability to climatic changes. To reduce the exposure of ski areas towards changes in natural snow conditions as well as to generally enhance snow conditions at skiing sites, technical snowmaking is widely utilized across Austrian ski areas. While such measures result in better snow conditions at the skiing sites and are important for the local skiing industry, its economic efficiency has also to be taken into account. The current work emerges from the project CC-Snow II, where improved future climate scenario simulations are used to determine future natural and artificial snow conditions and their effects on tourism and economy in the Austrian Alps. In a first step, a simple technical snowmaking approach is incorporated into the process based snow model AMUNDSEN, which operates at a spatial resolution of 10-50 m and a temporal resolution of 1-3 hours. Locations of skiing slopes within a ski area in Styria, Austria, were digitized and imported into the model environment. During a predefined time frame in the beginning of the ski season, the model produces a maximum possible amount of technical snow and distributes the associated snow on the slopes, whereas afterwards, until to the end of the ski season, the model tries to maintain a certain snow depth threshold value on the slopes. Due to only few required input parameters, this approach is easily transferable to other ski areas. In our poster contribution, we present first results of this snowmaking approach and give an overview of the data and methodology applied. In a further step in CC-Snow, this simple bulk approach will be extended to consider actual snow cannon locations and technical specifications, which will allow a more detailed description of technical snow production as well as cannon-based recordings of water and energy consumption.
2018-01-01
A simple, sensitive, accurate, robust headspace gas chromatographic method was developed for the quantitative determination of acetone and isopropyl alcohol in tartaric acid-based pellets of dipyridamole modified release capsules. The residual solvents acetone and isopropyl alcohol were used in the manufacturing process of the tartaric acid-based pellets of dipyridamole modified release capsules by considering the solubility of the dipyridamole and excipients in the different manufacturing stages. The method was developed and optimized by using fused silica DB-624 (30 m × 0.32 mm × 1.8 µm) column with the flame ionization detector. The method validation was carried out with regard to the guidelines for validation of analytical procedures Q2 demanded by the International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use (ICH). All the validation characteristics were meeting the acceptance criteria. Hence, the developed and validated method can be applied for the intended routine analysis. PMID:29686931
Valavala, Sriram; Seelam, Nareshvarma; Tondepu, Subbaiah; Jagarlapudi, V Shanmukha Kumar; Sundarmurthy, Vivekanandan
2018-01-01
A simple, sensitive, accurate, robust headspace gas chromatographic method was developed for the quantitative determination of acetone and isopropyl alcohol in tartaric acid-based pellets of dipyridamole modified release capsules. The residual solvents acetone and isopropyl alcohol were used in the manufacturing process of the tartaric acid-based pellets of dipyridamole modified release capsules by considering the solubility of the dipyridamole and excipients in the different manufacturing stages. The method was developed and optimized by using fused silica DB-624 (30 m × 0.32 mm × 1.8 µ m) column with the flame ionization detector. The method validation was carried out with regard to the guidelines for validation of analytical procedures Q2 demanded by the International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use (ICH). All the validation characteristics were meeting the acceptance criteria. Hence, the developed and validated method can be applied for the intended routine analysis.
Advanced thermally stable jet fuels. Technical progress report, January 1995--March 1995
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schobert, H.H.; Eser, S.; Song, C.
Quantitative structure-property relationships have been applied to study the thermal stability of pure hydrocarbons typical of jet fuel components. A simple method of chemical structure description in terms of Benson groups was tested in searching for structure-property relationships for the hydrocarbons tested experimentally in this program. Molecular connectivity as a structure-based approach to chemical structure-property relationship analysis was also tested. Further development of both the experimental data base and computational methods will be necessary. Thermal decomposition studies, using glass tube reactors, were extended to two additional model compounds: n-decane and n-dodecane. Efforts on refining the deposit growth measurement and characterizationmore » of suspended matter in stressed fuels have lead to improvements in the analysis of stressed fuels. Catalytic hydrogenation and dehydrogenation studies utilizing a molybdenum sulfide catalyst are also described.« less
NASA Astrophysics Data System (ADS)
Czechowski, Piotr Oskar; Owczarek, Tomasz; Badyda, Artur; Majewski, Grzegorz; Rogulski, Mariusz; Ogrodnik, Paweł
2018-01-01
The paper presents selected preliminary stage key issues proposed extended equivalence measurement results assessment for new portable devices - the comparability PM10 concentration results hourly series with reference station measurement results with statistical methods. In article presented new portable meters technical aspects. The emphasis was placed on the comparability the results using the stochastic and exploratory methods methodology concept. The concept is based on notice that results series simple comparability in the time domain is insufficient. The comparison of regularity should be done in three complementary fields of statistical modeling: time, frequency and space. The proposal is based on model's results of five annual series measurement results new mobile devices and WIOS (Provincial Environmental Protection Inspectorate) reference station located in Nowy Sacz city. The obtained results indicate both the comparison methodology completeness and the high correspondence obtained new measurements results devices with reference.
Liquid crystal thermography and true-colour digital image processing
NASA Astrophysics Data System (ADS)
Stasiek, J.; Stasiek, A.; Jewartowski, M.; Collins, M. W.
2006-06-01
In the last decade thermochromic liquid crystals (TLC) and true-colour digital image processing have been successfully used in non-intrusive technical, industrial and biomedical studies and applications. Thin coatings of TLCs at surfaces are utilized to obtain detailed temperature distributions and heat transfer rates for steady or transient processes. Liquid crystals also can be used to make visible the temperature and velocity fields in liquids by the simple expedient of directly mixing the liquid crystal material into the liquid (water, glycerol, glycol, and silicone oils) in very small quantities to use as thermal and hydrodynamic tracers. In biomedical situations e.g., skin diseases, breast cancer, blood circulation and other medical application, TLC and image processing are successfully used as an additional non-invasive diagnostic method especially useful for screening large groups of potential patients. The history of this technique is reviewed, principal methods and tools are described and some examples are also presented.
[Secure e-mail between physicians--aspect of a telemedicine platform for the health care system].
Goetz, C F
2001-10-01
Ever since the Roland-Berger-Study in 1997, the concept of a "telematics platform" for health care describes the combination of all technical and organizational components and services for the online transmission of patient data. This platform works on an interoperable collection of standards for addressing, security and content-description. In this context the security for application and transport data is based on data protection as well as medical non-disclosure rules. The methods of cryptography can provide security services for data transmitted realizing addressed, direct and indirect privacy. The first German health professional card, the electronic physicians' ID, provides central tools for such applications. First functionally simple pilot projects will prove the effectiveness of chosen methods in this year, even if not all identified construction sites in health care telematics have yet been lead towards a finalized solution.
Bogdanov-Berezovsky, Alexander; Pagkalos, Vasileios A.; Silberstein, Eldad; Xanthinaki, Arsinoi A.; Krieger, Yuval
2014-01-01
Background. Being predictive of the entire nodal bed, sentinel lymph node biopsy (SLNB) is invaluable in the surgical management of melanoma. Although the concept is simple, sentinel lymph node (SLN) identification and removal can be technically challenging. Methods. A total of 102 consecutive patients have undergone SLNB in the Division of Plastic and Reconstructive Surgery of Soroka University Medical Center from 2009 to 2012. Patients have undergone SLNB using a radioactive tracer and blue stain in order to identify the SLN. Although SLNB usually precedes the wide excision of melanoma, primary lesions in close proximity (<10 cm) to the lymph basin require wide excision before beginning the SLN quest. Results. All pathology reports confirmed the excision of lymph nodes. Conclusions. When treating MM in close proximity to the lymph basin, changing the sequence of the SLNB procedure seems to increase the efficacy of the method. PMID:24660067
Rapid and Easy Protocol for Quantification of Next-Generation Sequencing Libraries.
Hawkins, Steve F C; Guest, Paul C
2018-01-01
The emergence of next-generation sequencing (NGS) over the last 10 years has increased the efficiency of DNA sequencing in terms of speed, ease, and price. However, the exact quantification of a NGS library is crucial in order to obtain good data on sequencing platforms developed by the current market leader Illumina. Different approaches for DNA quantification are available currently and the most commonly used are based on analysis of the physical properties of the DNA through spectrophotometric or fluorometric methods. Although these methods are technically simple, they do not allow exact quantification as can be achieved using a real-time quantitative PCR (qPCR) approach. A qPCR protocol for DNA quantification with applications in NGS library preparation studies is presented here. This can be applied in various fields of study such as medical disorders resulting from nutritional programming disturbances.
Electrocoagulation in Water Treatment
NASA Astrophysics Data System (ADS)
Liu, Huijuan; Zhao, Xu; Qu, Jiuhui
Electrocoagulation (EC) is an electrochemical method of treating polluted water where sacrificial anodes corrode to release active coagulant precursors (usually aluminum or iron cations) into solution. At the cathode, gas evolves (usually as hydrogen bubbles) accompanying electrolytic reactions. EC needs simple equipments and is designable for virtually any size. It is cost effective and easily operable. Specially, the recent technical improvements combined with a growing need for small-scale water treatment facilities have led to a revaluation of EC. In this chapter, the basic principle of EC was introduced first. Following that, reactions at the electrodes and electrode assignment were reviewed; electrode passivation process and activation method were presented; comparison between electrocoagulation and chemical coagulation was performed; typical design of the EC reactors was also described; and factors affecting electrocoagulation including current density, effect of conductivity, temperature, and pH were introduced in details. Finally, application of EC in water treatment was given in details.
Shear in high strength concrete bridge girders : technical report.
DOT National Transportation Integrated Search
2013-04-01
Prestressed Concrete (PC) I-girders are used extensively as the primary superstructure components in Texas highway bridges. : A simple semi-empirical equation was developed at the University of Houston (UH) to predict the shear strength of PC I-girde...
Damping characterization in large structures
NASA Technical Reports Server (NTRS)
Eke, Fidelis O.; Eke, Estelle M.
1991-01-01
This research project has as its main goal the development of methods for selecting the damping characteristics of components of a large structure or multibody system, in such a way as to produce some desired system damping characteristics. The main need for such an analytical device is in the simulation of the dynamics of multibody systems consisting, at least partially, of flexible components. The reason for this need is that all existing simulation codes for multibody systems require component-by-component characterization of complex systems, whereas requirements (including damping) often appear at the overall system level. The main goal was met in large part by the development of a method that will in fact synthesize component damping matrices from a given system damping matrix. The restrictions to the method are that the desired system damping matrix must be diagonal (which is almost always the case) and that interbody connections must be by simple hinges. In addition to the technical outcome, this project contributed positively to the educational and research infrastructure of Tuskegee University - a Historically Black Institution.
NASA Astrophysics Data System (ADS)
Wang, Q.; Alfalou, A.; Brosseau, C.
2016-04-01
Here, we report a brief review on the recent developments of correlation algorithms. Several implementation schemes and specific applications proposed in recent years are also given to illustrate powerful applications of these methods. Following a discussion and comparison of the implementation of these schemes, we believe that all-numerical implementation is the most practical choice for application of the correlation method because the advantages of optical processing cannot compensate the technical and/or financial cost needed for an optical implementation platform. We also present a simple iterative algorithm to optimize the training images of composite correlation filters. By making use of three or four iterations, the peak-to-correlation energy (PCE) value of correlation plane can be significantly enhanced. A simulation test using the Pointing Head Pose Image Database (PHPID) illustrates the effectiveness of this statement. Our method can be applied in many composite filters based on linear composition of training images as an optimization means.
3D Structure Determination of Native Mammalian Cells using Cryo-FIB and Cryo-electron Tomography
Wang, Ke; Strunk, Korrinn; Zhao, Gongpu; Gray, Jennifer L.; Zhang, Peijun
2012-01-01
Cryo-electron tomography (cryo-ET) has enabled high resolution three-dimensional (3D) structural analysis of virus and host cell interactions and many cell signaling events; these studies, however, have largely been limited to very thin, peripheral regions of eukaryotic cells or to small prokaryotic cells. Recent efforts to make thin, vitreous sections using cryo-ultramicrotomy have been successful, however, this method is technically very challenging and with many artifacts. Here, we report a simple and robust method for creating in situ, frozen-hydrated cell lamellas using a focused ion beam at cryogenic temperature (cryo-FIB), allowing access to any interior cellular regions of interest. We demonstrate the utility of cryo-FIB with high resolution 3D cellular structures from both bacterial cells and large mammalian cells. The method will not only facilitate high-throughput 3D structural analysis of biological specimens, but is also broadly applicable to sample preparation of thin films and surface materials without the need for FIB “lift-out”. PMID:22796867
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-18
... DEPARTMENT OF AGRICULTURE Development of Technical Guidelines and Scientific Methods for... technical guidelines and scientific methods for quantifying greenhouse gas (GHG) emissions and carbon...-based methods to measure the carbon benefits from conservation and land management activities. In...
NASA Astrophysics Data System (ADS)
Devadhasan, Jasmine P.; Kim, Sanghyo
2015-07-01
Complementary metal oxide semiconductor (CMOS) image sensors are received great attention for their high efficiency in biological applications. The present work describes a CMOS image sensor-based whole blood glucose monitoring system through a point-of-care (POC) approach. A simple poly-ethylene terephthalate (PET) film chip was developed to carry out the enzyme kinetic reaction at various concentrations of blood glucose. In this technique, assay reagent was adsorbed onto amine functionalized silica (AFSiO2) nanoparticles in order to achieve glucose oxidation on the PET film chip. The AFSiO2 nanoparticles can immobilize the assay reagent with an electrostatic attraction and eased to develop the opaque platform which was technically suitable chip to analyze by the camera module. The oxidized glucose then produces a green color according to the glucose concentration and is analyzed by the camera module as a photon detection technique. The photon number decreases with increasing glucose concentration. The simple sensing approach, utilizing enzyme immobilized AFSiO2 nanoparticle chip and assay detection method was developed for quantitative glucose measurement.
Wang, Jing-Min; Lu, Chia-Liang
2013-03-06
The dual threats of energy depletion and global warming place the development of methods for harnessing renewable energy resources at the center of public interest. Solar energy is one of the most promising renewable energy resources. Sun trackers can substantially improve the electricity production of a photovoltaic (PV) system. This paper proposes a novel design of a dual-axis solar tracking PV system which utilizes the feedback control theory along with a four-quadrant light dependent resistor (LDR) sensor and simple electronic circuits to provide robust system performance. The proposed system uses a unique dual-axis AC motor and a stand-alone PV inverter to accomplish solar tracking. The control implementation is a technical innovation that is a simple and effective design. In addition, a scaled-down laboratory prototype is constructed to verify the feasibility of the scheme. The effectiveness of the Sun tracker is confirmed experimentally. To conclude, the results of this study may serve as valuable references for future solar energy applications.
Wang, Jing-Min; Lu, Chia-Liang
2013-01-01
The dual threats of energy depletion and global warming place the development of methods for harnessing renewable energy resources at the center of public interest. Solar energy is one of the most promising renewable energy resources. Sun trackers can substantially improve the electricity production of a photovoltaic (PV) system. This paper proposes a novel design of a dual-axis solar tracking PV system which utilizes the feedback control theory along with a four-quadrant light dependent resistor (LDR) sensor and simple electronic circuits to provide robust system performance. The proposed system uses a unique dual-axis AC motor and a stand-alone PV inverter to accomplish solar tracking. The control implementation is a technical innovation that is a simple and effective design. In addition, a scaled-down laboratory prototype is constructed to verify the feasibility of the scheme. The effectiveness of the Sun tracker is confirmed experimentally. To conclude, the results of this study may serve as valuable references for future solar energy applications. PMID:23467030
1980-02-01
Reserch Projects Agency I t&* ISO~p~A d m* ab~b ~I 41 b~bmso 544,A UNCLASSIFIED S@MYT SLAMIICAIGH OF TNNI PAOE tpvm Gamb.______________ RI...Wi do m,.we a#& N m WUNP SMei r -- This Quarterly Technical Report describes work on the development of and experimentation with packet broadcast by...interval by either segmenting or aggregating the stream packets such that they match the system interval. Since this approach is simple with respect
Li, Jia; Rossignol, Fabrice; Macdonald, Joanne
2015-06-21
Inkjet printing is emerging at the forefront of biosensor fabrication technologies. Parallel advances in both ink chemistry and printers have led to a biosensor manufacturing approach that is simple, rapid, flexible, high resolution, low cost, efficient for mass production, and extends the capabilities of devices beyond other manufacturing technologies. Here we review for the first time the factors behind successful inkjet biosensor fabrication, including printers, inks, patterning methods, and matrix types. We discuss technical considerations that are important when moving beyond theoretical knowledge to practical implementation. We also highlight significant advances in biosensor functionality that have been realised through inkjet printing. Finally, we consider future possibilities for biosensors enabled by this novel combination of chemistry and technology.
Velderraín, José Dávila; Martínez-García, Juan Carlos; Álvarez-Buylla, Elena R
2017-01-01
Mathematical models based on dynamical systems theory are well-suited tools for the integration of available molecular experimental data into coherent frameworks in order to propose hypotheses about the cooperative regulatory mechanisms driving developmental processes. Computational analysis of the proposed models using well-established methods enables testing the hypotheses by contrasting predictions with observations. Within such framework, Boolean gene regulatory network dynamical models have been extensively used in modeling plant development. Boolean models are simple and intuitively appealing, ideal tools for collaborative efforts between theorists and experimentalists. In this chapter we present protocols used in our group for the study of diverse plant developmental processes. We focus on conceptual clarity and practical implementation, providing directions to the corresponding technical literature.
Simple-to-prepare multipoint field emitter
NASA Astrophysics Data System (ADS)
Sominskii, G. G.; Taradaev, E. P.; Tumareva, T. A.; Mishin, M. V.; Kornishin, S. Yu.
2015-07-01
We investigate multitip field emitters prepared by electroerosion treatment of the surface of molybdenum samples. Their characteristics are determined for operation with a protecting activated fullerene coating. Our experiments indicate that such cathodes are promising for high-voltage electron devices operating in technical vacuum.
Hassan, Wafaa S; Elmasry, Manal S; Elsayed, Heba M; Zidan, Dalia W
2018-09-05
In accordance with International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH) guidelines, six novel, simple and precise sequential spectrophotometric methods were developed and validated for the simultaneous analysis of Ribavirin (RIB), Sofosbuvir (SOF), and Daclatasvir (DAC) in their mixture without prior separation steps. These drugs are described as co-administered for treatment of Hepatitis C virus (HCV). HCV is the cause of hepatitis C and some cancers such as liver cancer (hepatocellular carcinoma) and lymphomas in humans. These techniques consisted of several sequential steps using zero, ratio and/or derivative spectra. DAC was first determined through direct spectrophotometry at 313.7 nm without any interference of the other two drugs while RIB and SOF can be determined after ratio subtraction through five methods; Ratio difference spectrophotometric method, successive derivative ratio method, constant center, isoabsorptive method at 238.8 nm, and mean centering of the ratio spectra (MCR) at 224 nm and 258 nm for RIB and SOF, respectively. The calibration curve is linear over the concentration ranges of (6-42), (10-70) and (4-16) μg/mL for RIB, SOF, and DAC, respectively. This method was successfully applied to commercial pharmaceutical preparation of the drugs, spiked human urine, and spiked human plasma. The above methods are very simple methods that were developed for the simultaneous determination of binary and ternary mixtures and so enhance signal-to-noise ratio. The method has been successfully applied to the simultaneous analysis of RIB, SOF, and DAC in laboratory prepared mixtures. The obtained results are statistically compared with those obtained by the official or reported methods, showing no significant difference with respect to accuracy and precision at p = 0.05. Copyright © 2018 Elsevier B.V. All rights reserved.
A microchip CD4 counting method for HIV monitoring in resource-poor settings.
Rodriguez, William R; Christodoulides, Nicolaos; Floriano, Pierre N; Graham, Susan; Mohanty, Sanghamitra; Dixon, Meredith; Hsiang, Mina; Peter, Trevor; Zavahir, Shabnam; Thior, Ibou; Romanovicz, Dwight; Bernard, Bruce; Goodey, Adrian P; Walker, Bruce D; McDevitt, John T
2005-07-01
More than 35 million people in developing countries are living with HIV infection. An enormous global effort is now underway to bring antiretroviral treatment to at least 3 million of those infected. While drug prices have dropped considerably, the cost and technical complexity of laboratory tests essential for the management of HIV disease, such as CD4 cell counts, remain prohibitive. New, simple, and affordable methods for measuring CD4 cells that can be implemented in resource-scarce settings are urgently needed. Here we describe the development of a prototype for a simple, rapid, and affordable method for counting CD4 lymphocytes. Microliter volumes of blood without further sample preparation are stained with fluorescent antibodies, captured on a membrane within a miniaturized flow cell and imaged through microscope optics with the type of charge-coupled device developed for digital camera technology. An associated computer algorithm converts the raw digital image into absolute CD4 counts and CD4 percentages in real time. The accuracy of this prototype system was validated through testing in the United States and Botswana, and showed close agreement with standard flow cytometry (r = 0.95) over a range of absolute CD4 counts, and the ability to discriminate clinically relevant CD4 count thresholds with high sensitivity and specificity. Advances in the adaptation of new technologies to biomedical detection systems, such as the one described here, promise to make complex diagnostics for HIV and other infectious diseases a practical global reality.
Method of identification of patent trends based on descriptions of technical functions
NASA Astrophysics Data System (ADS)
Korobkin, D. M.; Fomenkov, S. A.; Golovanchikov, A. B.
2018-05-01
The use of the global patent space to determine the scientific and technological priorities for the technical systems development (identifying patent trends) allows one to forecast the direction of the technical systems development and, accordingly, select patents of priority technical subjects as a source for updating the technical functions database and physical effects database. The authors propose an original method that uses as trend terms not individual unigrams or n-gram (usually for existing methods and systems), but structured descriptions of technical functions in the form “Subject-Action-Object” (SAO), which in the authors’ opinion are the basis of the invention.
Authorship attribution based on Life-Like Network Automata
Machicao, Jeaneth; Corrêa, Edilson A.; Miranda, Gisele H. B.; Amancio, Diego R.
2018-01-01
The authorship attribution is a problem of considerable practical and technical interest. Several methods have been designed to infer the authorship of disputed documents in multiple contexts. While traditional statistical methods based solely on word counts and related measurements have provided a simple, yet effective solution in particular cases; they are prone to manipulation. Recently, texts have been successfully modeled as networks, where words are represented by nodes linked according to textual similarity measurements. Such models are useful to identify informative topological patterns for the authorship recognition task. However, there is no consensus on which measurements should be used. Thus, we proposed a novel method to characterize text networks, by considering both topological and dynamical aspects of networks. Using concepts and methods from cellular automata theory, we devised a strategy to grasp informative spatio-temporal patterns from this model. Our experiments revealed an outperformance over structural analysis relying only on topological measurements, such as clustering coefficient, betweenness and shortest paths. The optimized results obtained here pave the way for a better characterization of textual networks. PMID:29566100
Gaikwad, Ravi M.; Dokukin, Maxim E.; Iyer, K. Swaminathan; Woodworth, Craig D.; Volkov, Dmytro O.; Sokolov, Igor
2012-01-01
Here we describe a non-traditional method to identify cancerous human cervical epithelial cells in a culture dish based on physical interaction between silica beads and cells. It is a simple optical fluorescence-based technique which detects the relative difference in the amount of fluorescent silica beads physically adherent to surfaces of cancerous and normal cervical cells. The method utilizes the centripetal force gradient that occurs in a rotating culture dish. Due to the variation in the balance between adhesion and centripetal forces, cancerous and normal cells demonstrate clearly distinctive distributions of the fluorescent particles adherent to the cell surface over the culture dish. The method demonstrates higher adhesion of silica particles to normal cells compared to cancerous cells. The difference in adhesion was initially observed by atomic force microscopy (AFM). The AFM data were used to design the parameters of the rotational dish experiment. The optical method that we describe is much faster and technically simpler than AFM. This work provides proof of the concept that physical interactions can be used to accurately discriminate normal and cancer cells. PMID:21305062
Today's Students, Tomorrow's Leaders
ERIC Educational Resources Information Center
Reese, Susan
2008-01-01
According to Warren Bennis, professor at the University of Southern California's Marshall School of Business and a recognized authority on organizational development, leadership and change, becoming a leader is synonymous with becoming oneself. It is precisely that simple, and it is also that difficult. In career and technical student…
FIELD EVALUATION OF THE IN-SITU TREATMENTS TO REDUCE SOIL LEAD BIOAVAILABILITY: CONCLUSIONS
This presentation summarizes the conclusion of the technical issues associated with the Pb bioavailability experiment which IINERT has been conducting and further to illustrate that although bioavailability is a simple concept, its measurement and the implementation of the measur...
RESTORING WILD SALMON TO THE PACIFIC NORTHWEST: WHAT DOES RISK ASSESSMENT OFFER?
Over the past two decades, risk assessment has become the most popular analytic approach to evaluate ecological policy options. Its principal use has been to evaluate relatively simple technical questions (e.g., regulatory actions associated with specific chemicals or hazardous ...
Robertson, Eleanor; Morgan, Lauren; New, Steve; Pickering, Sharon; Hadi, Mohammed; Collins, Gary; Rivero Arias, Oliver; Griffin, Damian; McCulloch, Peter
2015-01-01
Background To investigate the effectiveness of combining teamwork training and lean process improvement, two distinct approaches to improving surgical safety. We conducted a controlled interrupted time series study in a specialist UK Orthopaedic hospital incorporating a plastic surgery team (which received the intervention) and an Orthopaedic theatre team acting as a control. Study Design We used a 3 month intervention with 3 months data collection period before and after it. A combined teamwork training and lean process improvement intervention was delivered by an experienced specialist team. Before and after the intervention we evaluated team non-technical skills using NOTECHS II, technical performance using the glitch rate and WHO checklist compliance using a simple 3 point scale. We recorded complication rate, readmission rate and length of hospital stay data for 6 months before and after the intervention. Results In the active group, but not the control group, full compliance with WHO Time Out (T/O) increased from 14 to 71% (p = 0.032), Sign Out attempt rate (S/O) increased from 0% to 50% (p<0.001) and Oxford NOTECHS II scores increased after the intervention (P = 0.058). Glitch rate decreased in the active group and increased in the control group (p = 0.001). Complications and length of stay appeared to rise in the control group and fall in the active group. Conclusions Combining teamwork training and systems improvement enhanced both technical and non-technical operating team process measures, and were associated with a trend to better safety outcome measures in a controlled study comparison. We suggest that approaches which address both system and culture dimensions of safety may prove valuable in reducing risks to patients. PMID:26381643
Journy, N; Sinno-Tellier, S; Maccia, C; Le Tertre, A; Pirard, P; Pagès, P; Eilstein, D; Donadieu, J; Bar, O
2012-01-01
Objective The study aimed to characterise the factors related to the X-ray dose delivered to the patient's skin during interventional cardiology procedures. Methods We studied 177 coronary angiographies (CAs) and/or percutaneous transluminal coronary angioplasties (PTCAs) carried out in a French clinic on the same radiography table. The clinical and therapeutic characteristics, and the technical parameters of the procedures, were collected. The dose area product (DAP) and the maximum skin dose (MSD) were measured by an ionisation chamber (Diamentor; Philips, Amsterdam, The Netherlands) and radiosensitive film (Gafchromic; International Specialty Products Advanced Materials Group, Wayne, NJ). Multivariate analyses were used to assess the effects of the factors of interest on dose. Results The mean MSD and DAP were respectively 389 mGy and 65 Gy cm−2 for CAs, and 916 mGy and 69 Gy cm−2 for PTCAs. For 8% of the procedures, the MSD exceeded 2 Gy. Although a linear relationship between the MSD and the DAP was observed for CAs (r=0.93), a simple extrapolation of such a model to PTCAs would lead to an inadequate assessment of the risk, especially for the highest dose values. For PTCAs, the body mass index, the therapeutic complexity, the fluoroscopy time and the number of cine frames were independent explanatory factors of the MSD, whoever the practitioner was. Moreover, the effect of technical factors such as collimation, cinematography settings and X-ray tube orientations on the DAP was shown. Conclusion Optimising the technical options for interventional procedures and training staff on radiation protection might notably reduce the dose and ultimately avoid patient skin lesions. PMID:22457404
Efficient IDUA Gene Mutation Detection with Combined Use of dHPLC and Dried Blood Samples
Duarte, Ana Joana; Vieira, Luis
2013-01-01
Objectives. Development of a simple mutation directed method in order to allow lowering the cost of mutation testing using an easily obtainable biological material. Assessment of the feasibility of such method was tested using a GC-rich amplicon. Design and Methods. A method of denaturing high-performance liquid chromatography (dHPLC) was improved and implemented as a technique for the detection of variants in exon 9 of the IDUA gene. The optimized method was tested in 500 genomic DNA samples obtained from dried blood spots (DBS). Results. With this dHPLC approach it was possible to detect different variants, including the common p.Trp402Ter mutation in the IDUA gene. The high GC content did not interfere with the resolution and reliability of this technique, and discrimination of G-C transversions was also achieved. Conclusion. This PCR-based dHPLC method is proved to be a rapid, a sensitive, and an excellent option for screening numerous samples obtained from DBS. Furthermore, it resulted in the consistent detection of clearly distinguishable profiles of the common p.Trp402Ter IDUA mutation with an advantageous balance of cost and technical requirements. PMID:27335677
Simple Automatic File Exchange (SAFE) to Support Low-Cost Spacecraft Operation via the Internet
NASA Technical Reports Server (NTRS)
Baker, Paul; Repaci, Max; Sames, David
1998-01-01
Various issues associated with Simple Automatic File Exchange (SAFE) are presented in viewgraph form. Specific topics include: 1) Packet telemetry, Internet IP networks and cost reduction; 2) Basic functions and technical features of SAFE; 3) Project goals, including low-cost satellite transmission to data centers to be distributed via an Internet; 4) Operations with a replicated file protocol; 5) File exchange operation; 6) Ground stations as gateways; 7) Lessons learned from demonstrations and tests with SAFE; and 8) Feedback and future initiatives.
Mazzocato, Pamela; Stenfors-Hayes, Terese; von Thiele Schwarz, Ulrica; Hasson, Henna
2016-01-01
Objectives Kaizen, or continuous improvement, lies at the core of lean. Kaizen is implemented through practices that enable employees to propose ideas for improvement and solve problems. The aim of this study is to describe the types of issues and improvement suggestions that hospital employees feel empowered to address through kaizen practices in order to understand when and how kaizen is used in healthcare. Methods We analysed 186 structured kaizen documents containing improvement suggestions that were produced by 165 employees at a Swedish hospital. Directed content analysis was used to categorise the suggestions into following categories: type of situation (proactive or reactive) triggering an action; type of process addressed (technical/administrative, support and clinical); complexity level (simple or complex); and type of outcomes aimed for (operational or sociotechnical). Compliance to the kaizen template was calculated. Results 72% of the improvement suggestions were reactions to a perceived problem. Support, technical and administrative, and primary clinical processes were involved in 47%, 38% and 16% of the suggestions, respectively. The majority of the kaizen documents addressed simple situations and focused on operational outcomes. The degree of compliance to the kaizen template was high for several items concerning the identification of problems and the proposed solutions, and low for items related to the test and implementation of solutions. Conclusions There is a need to combine kaizen practices with improvement and innovation practices that help staff and managers to address complex issues, such as the improvement of clinical care processes. The limited focus on sociotechnical aspects and the partial compliance to kaizen templates may indicate a limited understanding of the entire kaizen process and of how it relates to the overall organisational goals. This in turn can hamper the sustainability of kaizen practices and results. PMID:27473953
Guissart, C; Dubucs, C; Raynal, C; Girardet, A; Tran Mau Them, F; Debant, V; Rouzier, C; Boureau-Wirth, A; Haquet, E; Puechberty, J; Bieth, E; Dupin Deguine, D; Khau Van Kien, P; Brechard, M P; Pritchard, V; Koenig, M; Claustres, M; Vincent, M C
2017-03-01
Analysis of cell-free foetal DNA (cff-DNA) in maternal plasma is very promising for early diagnosis of monogenic diseases; in particular, cystic fibrosis (CF). However, NIPD of single-gene disorders has been limited by the availability of suitable technical platforms and the need to set up patient or disease-specific custom-made approaches. To make research applications more readily accessible to the clinic, we offer a simple assay combining two independent methods to determine the presence or absence of paternally inherited foetal allele p.Phe508del (the most frequent mutation in CF patients worldwide). The first method detects the presence or absence of a p.Phe508del allele by Mutant Enrichment with 3'-Modified Oligonucleotide PCR coupled to Fragment Length Analysis (MEMO-PCR-FLA). The second method detects the p.Phe508del allele with classical Multiplex Fluorescent PCR including five intragenic and extragenic STR markers of the CFTR locus and a specific SRY sequence. We collected 24 plasma samples from 23 women carrying foetuses at risk for CF and tested each sample using both methods. Our new procedures were successfully applied to 10 couples where fathers carried the p.Phe508del mutation and mothers were carrying a different mutation in the CFTR gene. These simple tests provided clear positive or negative results from the maternal plasma of the pregnant women. We confirmed the presence of cff-DNA in the studied samples by the identification of a tri-allelic DNA profile using a miniSTR kit. All results were correlated with chorionic villus sampling or amniocentesis analyses. This NIPD approach, easily set up in any clinical laboratory where prenatal diagnosis is routinely performed, offers many advantages over current methods: it is simple, rapid, and cost-effective. It opens up the possibility for testing a large number of couples with offspring at risk for CF. Copyright © 2016 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.
Does anyone understand HMO advertising?
Bisinger, J M
1986-12-01
Much HMO advertising is executed with technical proficiency, but a high level of technical skill cannot compensate for poor objectives, an inadequate analysis of the business situation, or a lack of advertising effectiveness. Industrial marketing techniques often involve person-to-person selling via a sales staff, sales reps, on-site technical assistance and informational meetings, team selling, etc. Some HMOs also employ these techniques. In general, the promotional focus in these situations is not on mass media; communication tends to be in support of personal sales activities. These personal techniques are used because of the difficulty of selling complicated products or services. Is an HMO a simple product/service? If it is not, consumer promotional tactics will probably be ineffective. If used, these promotional tactics probably will be unintelligible because "consumers" do not select HMOs; their employers do.
Composite Socio-Technical Systems: A Method for Social Energy Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Yingchen; He, Fulin; Hao, Jun
In order to model and study the interactions between social on technical systems, a systemic method, namely the composite socio-technical systems (CSTS), is proposed to incorporate social systems, technical systems and the interaction mechanism between them. A case study on University of Denver (DU) campus grid is presented in paper to demonstrate the application of the proposed method. In the case study, the social system, technical system, and the interaction mechanism are defined and modelled within the framework of CSTS. Distributed and centralized control and management schemes are investigated, respectively, and numerical results verifies the feasibility and performance of themore » proposed composite system method.« less
Violence in the Workplace: Avoiding Institutional Liability.
ERIC Educational Resources Information Center
Marsh, Ranaye J.; Hall, Bradley H.
This document is intended to provide career and technical education faculty and administrators with information on institutional liability relating to workplace violence as documented in court cases. The major legislation regarding violence in schools is summarized. Seventeen warning signs of violence are presented along with simple steps…
ERIC Educational Resources Information Center
Antippa, Adel F.
2009-01-01
We solve the problem of the relativistic rocket by making use of the relation between Lorentzian and Galilean velocities, as well as the laws of superposition of successive collinear Lorentz boosts in the limit of infinitesimal boosts. The solution is conceptually simple, and technically straightforward, and provides an example of a powerful…
Kim, Manuela; Stripeikis, Jorge; Iñón, Fernando; Tudino, Mabel
2007-05-15
A simple and sensitive HPLC post-derivatization method with colorimetric detection has been developed for the determination of N-nitroso glyphosate in samples of technical glyphosate. Separation of the analyte was accomplished using an anionic exchange resin (2.50mmx4.00mm i.d., 15mum particle size, functional group: quaternary ammonium salt) with Na(2)SO(4) 0.0075M (pH 11.5) (flow rate: 1.0mLmin(-1)) as mobile phase. After separation, the eluate was derivatized with a colorimetric reagent containing sulfanilamide 0.3% (w/v), [N-(1-naphtil)ethilendiamine] 0.03% (w/v) and HCl 4.5M in a thermostatized bath at 95 degrees C. Detection was performed at 546nm. All stages of the analytical procedure were optimized taking into account the concept of analytical minimalism: less operation times and costs; lower sample, reagents and energy consumption and minimal waste. The limit of detection (k=3) calculated for 10 blank replicates was 0.04mgL(-1) (0.8mgkg(-1)) in the solid sample which is lower than the maximum tolerable accepted by the Food and Agriculture Organization of the United Nations.
Jenett, Benjamin; Calisch, Sam; Cellucci, Daniel; Cramer, Nick; Gershenfeld, Neil; Swei, Sean; Cheung, Kenneth C
2017-03-01
We describe an approach for the discrete and reversible assembly of tunable and actively deformable structures using modular building block parts for robotic applications. The primary technical challenge addressed by this work is the use of this method to design and fabricate low density, highly compliant robotic structures with spatially tuned stiffness. This approach offers a number of potential advantages over more conventional methods for constructing compliant robots. The discrete assembly reduces manufacturing complexity, as relatively simple parts can be batch-produced and joined to make complex structures. Global mechanical properties can be tuned based on sub-part ordering and geometry, because local stiffness and density can be independently set to a wide range of values and varied spatially. The structure's intrinsic modularity can significantly simplify analysis and simulation. Simple analytical models for the behavior of each building block type can be calibrated with empirical testing and synthesized into a highly accurate and computationally efficient model of the full compliant system. As a case study, we describe a modular and reversibly assembled wing that performs continuous span-wise twist deformation. It exhibits high performance aerodynamic characteristics, is lightweight and simple to fabricate and repair. The wing is constructed from discrete lattice elements, wherein the geometric and mechanical attributes of the building blocks determine the global mechanical properties of the wing. We describe the mechanical design and structural performance of the digital morphing wing, including their relationship to wind tunnel tests that suggest the ability to increase roll efficiency compared to a conventional rigid aileron system. We focus here on describing the approach to design, modeling, and construction as a generalizable approach for robotics that require very lightweight, tunable, and actively deformable structures.
Digital Morphing Wing: Active Wing Shaping Concept Using Composite Lattice-Based Cellular Structures
Jenett, Benjamin; Calisch, Sam; Cellucci, Daniel; Cramer, Nick; Gershenfeld, Neil; Swei, Sean
2017-01-01
Abstract We describe an approach for the discrete and reversible assembly of tunable and actively deformable structures using modular building block parts for robotic applications. The primary technical challenge addressed by this work is the use of this method to design and fabricate low density, highly compliant robotic structures with spatially tuned stiffness. This approach offers a number of potential advantages over more conventional methods for constructing compliant robots. The discrete assembly reduces manufacturing complexity, as relatively simple parts can be batch-produced and joined to make complex structures. Global mechanical properties can be tuned based on sub-part ordering and geometry, because local stiffness and density can be independently set to a wide range of values and varied spatially. The structure's intrinsic modularity can significantly simplify analysis and simulation. Simple analytical models for the behavior of each building block type can be calibrated with empirical testing and synthesized into a highly accurate and computationally efficient model of the full compliant system. As a case study, we describe a modular and reversibly assembled wing that performs continuous span-wise twist deformation. It exhibits high performance aerodynamic characteristics, is lightweight and simple to fabricate and repair. The wing is constructed from discrete lattice elements, wherein the geometric and mechanical attributes of the building blocks determine the global mechanical properties of the wing. We describe the mechanical design and structural performance of the digital morphing wing, including their relationship to wind tunnel tests that suggest the ability to increase roll efficiency compared to a conventional rigid aileron system. We focus here on describing the approach to design, modeling, and construction as a generalizable approach for robotics that require very lightweight, tunable, and actively deformable structures. PMID:28289574
Automatic 3D relief acquisition and georeferencing of road sides by low-cost on-motion SfM
NASA Astrophysics Data System (ADS)
Voumard, Jérémie; Bornemann, Perrick; Malet, Jean-Philippe; Derron, Marc-Henri; Jaboyedoff, Michel
2017-04-01
3D terrain relief acquisition is important for a large part of geosciences. Several methods have been developed to digitize terrains, such as total station, LiDAR, GNSS or photogrammetry. To digitize road (or rail tracks) sides on long sections, mobile spatial imaging system or UAV are commonly used. In this project, we compare a still fairly new method -the SfM on-motion technics- with some traditional technics of terrain digitizing (terrestrial laser scanning, traditional SfM, UAS imaging solutions, GNSS surveying systems and total stations). The SfM on-motion technics generates 3D spatial data by photogrammetric processing of images taken from a moving vehicle. Our mobile system consists of six action cameras placed on a vehicle. Four fisheye cameras mounted on a mast on the vehicle roof are placed at 3.2 meters above the ground. Three of them have a GNNS chip providing geotagged images. Two pictures were acquired every second by each camera. 4K resolution fisheye videos were also used to extract 8.3M not geotagged pictures. All these pictures are then processed with the Agisoft PhotoScan Professional software. Results from the SfM on-motion technics are compared with results from classical SfM photogrammetry on a 500 meters long alpine track. They were also compared with mobile laser scanning data on the same road section. First results seem to indicate that slope structures are well observable up to decimetric accuracy. For the georeferencing, the planimetric (XY) accuracy of few meters is much better than the altimetric (Z) accuracy. There is indeed a Z coordinate shift of few tens of meters between GoPro cameras and Garmin camera. This makes necessary to give a greater freedom to altimetric coordinates in the processing software. Benefits of this low-cost SfM on-motion method are: 1) a simple setup to use in the field (easy to switch between vehicle types as car, train, bike, etc.), 2) a low cost and 3) an automatic georeferencing of 3D points clouds. Main disadvantages are: 1) results are less accurate than those from LiDAR system, 2) a heavy images processing and 3) a short distance of acquisition.
Christen, Andri; Navarro, Carlos Morante; Mäusezahl, Daniel
2009-09-01
Indoor air pollution and unsafe water remain two of the most important environmental risk factors for the global burden of infectious diseases. Improved stoves and household water treatment (HWT) methods represent two of the most effective interventions to fight respiratory and diarrhoeal illnesses at household level. Since new improved stoves are highly accepted and HWT methods have their drawbacks regarding sustained use, combining the two interventions in one technical solution could result in notable positive convenience and health benefits. A WAter DIsinfection Stove (WADIS) based on a Lorena-stove design with a simple flow-through boiling water-treatment system was developed and tested by a pilot experimental study in rural Bolivia. The results of a post-implementation evaluation of two WADIS and 27 Lorena-stoves indicate high social acceptance rather due to convenience gains of the stove than to perceived health improvements. The high efficacy of the WADIS-water treatment system, with a reduction of microbiological contamination load in the treated water from 87600 thermotolerant coliform colony forming units per 100mL (CFU/100mL) to zero is indicative. The WADIS concept unifies two interventions addressing two important global burdens of disease. WADIS' simple design, relying on locally available materials and low manufacturing costs (approx. 6 US) indicates potential for spontaneous diffusion and scaling up.
Operation of Direct Drive Systems: Experiments in Peak Power Tracking and Multi-Thruster Control
NASA Technical Reports Server (NTRS)
Snyder, John Steven; Brophy, John R.
2013-01-01
Direct-drive power and propulsion systems have the potential to significantly reduce the mass of high-power solar electric propulsion spacecraft, among other advantages. Recent experimental direct-drive work has significantly mitigated or retired the technical risks associated with single-thruster operation, so attention is now moving toward systems-level areas of interest. One of those areas is the use of a Hall thruster system as a peak power tracker to fully use the available power from a solar array. A simple and elegant control based on the incremental conductance method, enhanced by combining it with the unique properties of Hall thruster systems, is derived here and it is shown to track peak solar array power very well. Another area of interest is multi-thruster operation and control. Dualthruster operation was investigated in a parallel electrical configuration, with both thrusters operating from discharge power provided by a single solar array. Startup and shutdown sequences are discussed, and it is shown that multi-thruster operation and control is as simple as for a single thruster. Some system architectures require operation of multiple cathodes while they are electrically connected together. Four different methods to control the discharge current emitted by individual cathodes in this configuration are investigated, with cathode flow rate control appearing to be advantageous. Dual-parallel thruster operation with equal cathode current sharing at total powers up to 10 kW is presented.
NASA Astrophysics Data System (ADS)
Gainutdinov, A. M.; Read, N.; Saleur, H.
2016-01-01
We develop in this paper the principles of an associative algebraic approach to bulk logarithmic conformal field theories (LCFTs). We concentrate on the closed {gl(1|1)} spin-chain and its continuum limit—the {c=-2} symplectic fermions theory—and rely on two technical companion papers, Gainutdinov et al. (Nucl Phys B 871:245-288, 2013) and Gainutdinov et al. (Nucl Phys B 871:289-329, 2013). Our main result is that the algebra of local Hamiltonians, the Jones-Temperley-Lieb algebra JTL N , goes over in the continuum limit to a bigger algebra than {V}, the product of the left and right Virasoro algebras. This algebra, {S}—which we call interchiral, mixes the left and right moving sectors, and is generated, in the symplectic fermions case, by the additional field {S(z,bar{z})≡ S_{αβ} ψ^α(z)bar{ψ}^β(bar{z})}, with a symmetric form {S_{αβ}} and conformal weights (1,1). We discuss in detail how the space of states of the LCFT (technically, a Krein space) decomposes onto representations of this algebra, and how this decomposition is related with properties of the finite spin-chain. We show that there is a complete correspondence between algebraic properties of finite periodic spin chains and the continuum limit. An important technical aspect of our analysis involves the fundamental new observation that the action of JTL N in the {gl(1|1)} spin chain is in fact isomorphic to an enveloping algebra of a certain Lie algebra, itself a non semi-simple version of {sp_{N-2}}. The semi-simple part of JTL N is represented by {U sp_{N-2}}, providing a beautiful example of a classical Howe duality, for which we have a non semi-simple version in the full JTL N image represented in the spin-chain. On the continuum side, simple modules over {S} are identified with "fundamental" representations of {sp_∞}.
Laser Speckle Contrast Imaging of Cerebral Blood Flow
Dunn, Andrew K.
2011-01-01
Laser speckle contrast imaging (LSCI) has emerged over the past decade as a powerful, yet simple, method for imaging of blood flow dynamics in real time. The rapid adoption of LSCI for physiological studies is due to the relative ease and low cost of building an instrument as well as the ability to quantify blood flow changes with excellent spatial and temporal resolution. Although measurements are limited to superficial tissues with no depth resolution, LSCI has been instrumental in pre-clinical studies of neurological disorders as well as clinical applications including dermatological, neurosurgical and endoscopic studies. Recently a number of technical advances have been developed to improve the quantitative accuracy and temporal resolution of speckle imaging. This article reviews some of these recent advances and describes several applications of speckle imaging. PMID:22109805
NASA Astrophysics Data System (ADS)
Lachieze-Rey, Marc
This book delivers a quantitative account of the science of cosmology, designed for a non-specialist audience. The basic principles are outlined using simple maths and physics, while still providing rigorous models of the Universe. It offers an ideal introduction to the key ideas in cosmology, without going into technical details. The approach used is based on the fundamental ideas of general relativity such as the spacetime interval, comoving coordinates, and spacetime curvature. It provides an up-to-date and thoughtful discussion of the big bang, and the crucial questions of structure and galaxy formation. Questions of method and philosophical approaches in cosmology are also briefly discussed. Advanced undergraduates in either physics or mathematics would benefit greatly from use either as a course text or as a supplementary guide to cosmology courses.
NASA Technical Reports Server (NTRS)
Sheverev, V. A.; Khromov, N. A.; Kojiro, D. R.; Fonda, Mark (Technical Monitor)
2002-01-01
Admixtures to helium of 100 ppm and 5 ppm of nitrogen, and 100 ppm and 10 ppm of carbon monoxide were identified and measured in the helium discharge afterglow using an electrical probe placed into the plasma. For nitrogen and carbon monoxide gases, the measured electron energy spectra display distinct characteristic peaks (fingerprints). Location of the peaks on the energy scale is determined by the ionization energies of the analyte molecules. Nitrogen and carbon monoxide fingerprints were also observed in a binary mixture of these gases in helium, and the relative concentration analytes has been predicted. The technically simple and durable method is considered a good candidate for a number of analytical applications, and in particular, in GC and for analytical flight instrumentation.
ERIC Educational Resources Information Center
MEYER, DONALD E.
TWO EXPERIMENTS WERE CONDUCTED TO EVALUATE A SELF-STUDY PROGRAM PREPARED WITHIN TWO OPERATIONAL FIGHTER-INTERCEPTOR SQUADRONS. BASED ON A TECHNICAL ORDER MANUAL, IT CONSISTED OF SEQUENCED MULTIPLE-CHOICE QUESTIONS WITH A SIMPLE PUNCHBOARD AS A CONFIRMING DEVICE. IN EXPERIMENT ONE, TWO OPERATIONAL SQUADRONS WERE DIVIDED INTO TWO GROUPS JUDGED TO BE…
Nonparametric Identification of Causal Effects under Temporal Dependence
ERIC Educational Resources Information Center
Dafoe, Allan
2018-01-01
Social scientists routinely address temporal dependence by adopting a simple technical fix. However, the correct identification strategy for a causal effect depends on causal assumptions. These need to be explicated and justified; almost no studies do so. This article addresses this shortcoming by offering a precise general statement of the…
78 FR 44459 - Rate Regulation Reforms
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-24
... the interest rate. A simple multiplication of the nominal rate by the portion of the year covered by... makes technical changes to the full and simplified rate procedures; changes the interest rate that... allocation methodology for cross-over traffic. Part IV sets out the change in the interest rate carriers must...
Magnetic Force and Work: An Accessible Example
ERIC Educational Resources Information Center
Gates, Joshua
2014-01-01
Despite their physics instructors' arguments to the contrary, introductory students can observe situations in which there seems to be compelling evidence for magnetic force doing work. The counterarguments are often highly technical and require physics knowledge beyond the experience of novice students, however. A simple example is presented…
Summer Program Introduces High School Students to Engineering.
ERIC Educational Resources Information Center
Worthy, Ward
1989-01-01
Discusses how, in two three-week sessions, the Terre Haute (Indiana) college offers selected students a hands-on approach to all aspects of engineering from design and lab work to technical writing. Describes a group project requiring students to study and experiment with simple research problems. Lists 20 project ideas. (MVL)
75 FR 56477 - Technical Amendments for Marine Spark-Ignition Engines and Vessels
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-16
... spillage, incorporating safe recommended practices will result in a net benefit to the environment and lead... portable fuel tanks to these new requirements, manufacturers working together on systems integration.... We have engaged the industry to identify a simple, safe, and emissions neutral solution to this...
Cross platform development using Delphi and Kylix
DOE Office of Scientific and Technical Information (OSTI.GOV)
McDonald, J.L.; Nishimura, H.; Timossi, C.
2002-10-08
A cross platform component for EPICS Simple Channel Access (SCA) has been developed for the use with Delphi on Windows and Kylix on Linux. An EPICS controls GUI application developed on Windows runs on Linux by simply rebuilding it, and vice versa. This paper describes the technical details of the component.
Teaching Technical and Business Writing: Strategies and Evaluation.
ERIC Educational Resources Information Center
Alexander, Clara
1985-01-01
Describes a course that gives students the kinds of writing and oral communication experiences they will need on the job. The course gives students information about effective speaking and teaches them how to write business letters, prepare simple visuals for written and oral reports, and write formal proposals. (EL)
Covariate Measurement Error Correction Methods in Mediation Analysis with Failure Time Data
Zhao, Shanshan
2014-01-01
Summary Mediation analysis is important for understanding the mechanisms whereby one variable causes changes in another. Measurement error could obscure the ability of the potential mediator to explain such changes. This paper focuses on developing correction methods for measurement error in the mediator with failure time outcomes. We consider a broad definition of measurement error, including technical error and error associated with temporal variation. The underlying model with the ‘true’ mediator is assumed to be of the Cox proportional hazards model form. The induced hazard ratio for the observed mediator no longer has a simple form independent of the baseline hazard function, due to the conditioning event. We propose a mean-variance regression calibration approach and a follow-up time regression calibration approach, to approximate the partial likelihood for the induced hazard function. Both methods demonstrate value in assessing mediation effects in simulation studies. These methods are generalized to multiple biomarkers and to both case-cohort and nested case-control sampling design. We apply these correction methods to the Women's Health Initiative hormone therapy trials to understand the mediation effect of several serum sex hormone measures on the relationship between postmenopausal hormone therapy and breast cancer risk. PMID:25139469
Covariate measurement error correction methods in mediation analysis with failure time data.
Zhao, Shanshan; Prentice, Ross L
2014-12-01
Mediation analysis is important for understanding the mechanisms whereby one variable causes changes in another. Measurement error could obscure the ability of the potential mediator to explain such changes. This article focuses on developing correction methods for measurement error in the mediator with failure time outcomes. We consider a broad definition of measurement error, including technical error, and error associated with temporal variation. The underlying model with the "true" mediator is assumed to be of the Cox proportional hazards model form. The induced hazard ratio for the observed mediator no longer has a simple form independent of the baseline hazard function, due to the conditioning event. We propose a mean-variance regression calibration approach and a follow-up time regression calibration approach, to approximate the partial likelihood for the induced hazard function. Both methods demonstrate value in assessing mediation effects in simulation studies. These methods are generalized to multiple biomarkers and to both case-cohort and nested case-control sampling designs. We apply these correction methods to the Women's Health Initiative hormone therapy trials to understand the mediation effect of several serum sex hormone measures on the relationship between postmenopausal hormone therapy and breast cancer risk. © 2014, The International Biometric Society.
An SNMP-based solution to enable remote ISO/IEEE 11073 technical management.
Lasierra, Nelia; Alesanco, Alvaro; García, José
2012-07-01
This paper presents the design and implementation of an architecture based on the integration of simple network management protocol version 3 (SNMPv3) and the standard ISO/IEEE 11073 (X73) to manage technical information in home-based telemonitoring scenarios. This architecture includes the development of an SNMPv3-proxyX73 agent which comprises a management information base (MIB) module adapted to X73. In the proposed scenario, medical devices (MDs) send information to a concentrator device [designated as compute engine (CE)] using the X73 standard. This information together with extra information collected in the CE is stored in the developed MIB. Finally, the information collected is available for remote access via SNMP connection. Moreover, alarms and events can be configured by an external manager in order to provide warnings of irregularities in the MDs' technical performance evaluation. This proposed SNMPv3 agent provides a solution to integrate and unify technical device management in home-based telemonitoring scenarios fully adapted to X73.
Management system of simple rental flats study based on technical aspect and health in Medan city
NASA Astrophysics Data System (ADS)
Novrial; Indra Cahaya, S.
2018-03-01
Medan city is a metropolis city in Sumatera that has slums area. Simple rental flats have been built to overcome the problem. However the preliminary survey result showed that the physical and non-physical environment management of simple rent flats is very bad. This study conducted in 3 simple rent flats. It has observed the simple rent flats environment and has interviewed occupants and related agencies. Results of conducted research showed the occupant’s characteristics based on the largest percentage are Javanese; last education is senior high with self-employed work with average income Rp 1,000,000 – Rp 2,500,000. Waste retribution submitted to their cleanliness except for Amplas simple rent flats, their waste management system does not manage properly and the garbage littered. The number of family members of Wisma Labuhan and Amplas simple rent flats exceeds the regulation number of occupants, so it is crowded and noisy. Physical conditions of Amplas simple rent flats are bad, septic tank is full and are not vacuumed. Clean water sources derived from wells and artesian wll are vulnerable to be contaminated by pollutants such as leachate and bad quality water. It is necessary to improve the physical, basic sanitation, and guidance for the simple rent flats occupants to the management system of Simple Rent Flats.
Andereggen, Lukas; Neuschmelting, Volker; von Gunten, Michael; Widmer, Hans Rudolf; Takala, Jukka; Jakob, Stephan M; Fandino, Javier; Marbacher, Serge
2014-10-02
Early brain injury and delayed cerebral vasospasm both contribute to unfavorable outcomes after subarachnoid hemorrhage (SAH). Reproducible and controllable animal models that simulate both conditions are presently uncommon. Therefore, new models are needed in order to mimic human pathophysiological conditions resulting from SAH. This report describes the technical nuances of a rabbit blood-shunt SAH model that enables control of intracerebral pressure (ICP). An extracorporeal shunt is placed between the arterial system and the subarachnoid space, which enables examiner-independent SAH in a closed cranium. Step-by-step procedural instructions and necessary equipment are described, as well as technical considerations to produce the model with minimal mortality and morbidity. Important details required for successful surgical creation of this robust, simple and consistent ICP-controlled SAH rabbit model are described.
Bubbles, shocks and elementary technical trading strategies
NASA Astrophysics Data System (ADS)
Fry, John
2014-01-01
In this paper we provide a unifying framework for a set of seemingly disparate models for bubbles, shocks and elementary technical trading strategies in financial markets. Markets operate by balancing intrinsic levels of risk and return. This seemingly simple observation is commonly over-looked by academics and practitioners alike. Our model shares its origins in statistical physics with others. However, under our approach, changes in market regime can be explicitly shown to represent a phase transition from random to deterministic behaviour in prices. This structure leads to an improved physical and econometric model. We develop models for bubbles, shocks and elementary technical trading strategies. The list of empirical applications is both interesting and topical and includes real-estate bubbles and the on-going Eurozone crisis. We close by comparing the results of our model with purely qualitative findings from the finance literature.
Wang, ShuQi; Lifson, Mark A.; Inci, Fatih; Liang, Li-Guo; Sheng, Ye-Feng; Demirci, Utkan
2016-01-01
The striking prevalence of HIV, TB and malaria, as well as outbreaks of emerging infectious diseases, such as influenza A (H7N9), Ebola and MERS, poses great challenges for patient care in resource-limited settings (RLS). However, advanced diagnostic technologies cannot be implemented in RLS largely due to economic constraints. Simple and inexpensive point-of-care (POC) diagnostics, which rely less on environmental context and operator training, have thus been extensively studied to achieve early diagnosis and treatment monitoring in non-laboratory settings. Despite great input from material science, biomedical engineering and nanotechnology for developing POC diagnostics, significant technical challenges are yet to be overcome. Summarized here are the technical challenges associated with POC diagnostics from a RLS perspective and the latest advances in addressing these challenges are reviewed. PMID:26777725
Impact of social preparedness on flood early warning systems
NASA Astrophysics Data System (ADS)
Girons Lopez, M.; Di Baldassarre, G.; Seibert, J.
2017-01-01
Flood early warning systems play a major role in the disaster risk reduction paradigm as cost-effective methods to mitigate flood disaster damage. The connections and feedbacks between the hydrological and social spheres of early warning systems are increasingly being considered as key aspects for successful flood mitigation. The behavior of the public and first responders during flood situations, determined by their preparedness, is heavily influenced by many behavioral traits such as perceived benefits, risk awareness, or even denial. In this study, we use the recency of flood experiences as a proxy for social preparedness to assess its impact on the efficiency of flood early warning systems through a simple stylized model and implemented this model using a simple mathematical description. The main findings, which are based on synthetic data, point to the importance of social preparedness for flood loss mitigation, especially in circumstances where the technical forecasting and warning capabilities are limited. Furthermore, we found that efforts to promote and preserve social preparedness may help to reduce disaster-induced losses by almost one half. The findings provide important insights into the role of social preparedness that may help guide decision-making in the field of flood early warning systems.
Chromophore Poling in Thin Films of Organic Glasses. 2. Two-Electrode Corona Discharge Setup
NASA Astrophysics Data System (ADS)
Vilitis, O.; Muzikante, I.; Rutkis, M.; Vembris, A.
2012-01-01
In Part 1 of the article we provided description of the corona discharge physics and overview of the methods used for corona poling in thin organic films. Subsequent sections describe comparatively simple technical methods for poling the organic nonlinear optical polymers using a two-electrode (point-to-plate or wire-to-plate) technique. The polarization build-up was studied by the DC positive corona method for poling the nonlinear optical (NLO) polymers. The experimental setup provides the corona discharge current from 0.5 μA up to 3 μA by applying 3 kV - 12 kV voltage to the corona electrode and makes possible selection among the types of corona electrodes (needle, multi-needle, wire, etc.). The results of experimental testing of the poling setup show that at fixed optimal operational parameters of poling - the sample orientation temperature and the discharge current - the corona charging of polymeric materials can successfully be performed applying the two-electrode technique. To study the dynamics of both poling and charge transport processes the three-electrode charging system - a corona triode - should be applied.
Loop-mediated isothermal PCR (LAMP) for the diagnosis of falciparum malaria.
Paris, Daniel H; Imwong, Mallika; Faiz, Abul M; Hasan, Mahtabuddin; Yunus, Emran Bin; Silamut, Kamolrat; Lee, Sue J; Day, Nicholas P J; Dondorp, Arjen M
2007-11-01
A recently described loop-mediated isothermal polymerase chain reaction (LAMP) for molecular detection of Plasmodium falciparum was compared with microscopy, PfHRP2-based rapid diagnostic test (RDT), and nested polymerase chain reaction (PCR) as the "gold standard" in 115 Bangladeshi in-patients with fever. DNA extraction for LAMP was conducted by conventional methods or simple heating of the sample; test results were either assessed visually or by gel electrophoresis. Conventional DNA extraction followed by gel electrophoresis had the highest agreement with the reference method (81.7%, kappa = 0.64), with a sensitivity (95% CI) of 76.1% (68.3-83.9%), comparable to RDT and microscopy, but a specificity of 89.6% (84.0-95.2%) compared with 100% for RDT and microscopy. DNA extraction by heat treatment deteriorated specificity to unacceptable levels. LAMP enables molecular diagnosis of falciparum malaria in settings with limited technical resources but will need further optimization. The results are in contrast with a higher accuracy reported in an earlier study comparing LAMP with a non-validated PCR method.
Applying Quantitative Genetic Methods to Primate Social Behavior
Brent, Lauren J. N.
2013-01-01
Increasingly, behavioral ecologists have applied quantitative genetic methods to investigate the evolution of behaviors in wild animal populations. The promise of quantitative genetics in unmanaged populations opens the door for simultaneous analysis of inheritance, phenotypic plasticity, and patterns of selection on behavioral phenotypes all within the same study. In this article, we describe how quantitative genetic techniques provide studies of the evolution of behavior with information that is unique and valuable. We outline technical obstacles for applying quantitative genetic techniques that are of particular relevance to studies of behavior in primates, especially those living in noncaptive populations, e.g., the need for pedigree information, non-Gaussian phenotypes, and demonstrate how many of these barriers are now surmountable. We illustrate this by applying recent quantitative genetic methods to spatial proximity data, a simple and widely collected primate social behavior, from adult rhesus macaques on Cayo Santiago. Our analysis shows that proximity measures are consistent across repeated measurements on individuals (repeatable) and that kin have similar mean measurements (heritable). Quantitative genetics may hold lessons of considerable importance for studies of primate behavior, even those without a specific genetic focus. PMID:24659839
G0-WISHART Distribution Based Classification from Polarimetric SAR Images
NASA Astrophysics Data System (ADS)
Hu, G. C.; Zhao, Q. H.
2017-09-01
Enormous scientific and technical developments have been carried out to further improve the remote sensing for decades, particularly Polarimetric Synthetic Aperture Radar(PolSAR) technique, so classification method based on PolSAR images has getted much more attention from scholars and related department around the world. The multilook polarmetric G0-Wishart model is a more flexible model which describe homogeneous, heterogeneous and extremely heterogeneous regions in the image. Moreover, the polarmetric G0-Wishart distribution dose not include the modified Bessel function of the second kind. It is a kind of simple statistical distribution model with less parameter. To prove its feasibility, a process of classification has been tested with the full-polarized Synthetic Aperture Radar (SAR) image by the method. First, apply multilook polarimetric SAR data process and speckle filter to reduce speckle influence for classification result. Initially classify the image into sixteen classes by H/A/α decomposition. Using the ICM algorithm to classify feature based on the G0-Wshart distance. Qualitative and quantitative results show that the proposed method can classify polaimetric SAR data effectively and efficiently.
A single-probe heat pulse method for estimating sap velocity in trees.
López-Bernal, Álvaro; Testi, Luca; Villalobos, Francisco J
2017-10-01
Available sap flow methods are still far from being simple, cheap and reliable enough to be used beyond very specific research purposes. This study presents and tests a new single-probe heat pulse (SPHP) method for monitoring sap velocity in trees using a single-probe sensor, rather than the multi-probe arrangements used up to now. Based on the fundamental conduction-convection principles of heat transport in sapwood, convective velocity (V h ) is estimated from the temperature increase in the heater after the application of a heat pulse (ΔT). The method was validated against measurements performed with the compensation heat pulse (CHP) technique in field trees of six different species. To do so, a dedicated three-probe sensor capable of simultaneously applying both methods was produced and used. Experimental measurements in the six species showed an excellent agreement between SPHP and CHP outputs for moderate to high flow rates, confirming the applicability of the method. In relation to other sap flow methods, SPHP presents several significant advantages: it requires low power inputs, it uses technically simpler and potentially cheaper instrumentation, the physical damage to the tree is minimal and artefacts caused by incorrect probe spacing and alignment are removed. © 2017 The Authors. New Phytologist © 2017 New Phytologist Trust.
Baym, Michael; Shaket, Lev; Anzai, Isao A; Adesina, Oluwakemi; Barstow, Buz
2016-11-10
Whole-genome knockout collections are invaluable for connecting gene sequence to function, yet traditionally, their construction has required an extraordinary technical effort. Here we report a method for the construction and purification of a curated whole-genome collection of single-gene transposon disruption mutants termed Knockout Sudoku. Using simple combinatorial pooling, a highly oversampled collection of mutants is condensed into a next-generation sequencing library in a single day, a 30- to 100-fold improvement over prior methods. The identities of the mutants in the collection are then solved by a probabilistic algorithm that uses internal self-consistency within the sequencing data set, followed by rapid algorithmically guided condensation to a minimal representative set of mutants, validation, and curation. Starting from a progenitor collection of 39,918 mutants, we compile a quality-controlled knockout collection of the electroactive microbe Shewanella oneidensis MR-1 containing representatives for 3,667 genes that is functionally validated by high-throughput kinetic measurements of quinone reduction.
Anomolous Fatigue Crack Growth Phenomena in High-Strength Steel
NASA Technical Reports Server (NTRS)
Forth, Scott C.; James, Mark A.; Johnston, William M., Jr.; Newman, James C., Jr.
2004-01-01
The growth of a fatigue crack through a material is the result of a complex interaction between the applied loading, component geometry, three-dimensional constraint, load history, environment, material microstructure and several other factors. Previous studies have developed experimental and computational methods to relate the fatigue crack growth rate to many of the above conditions, with the intent of discovering some fundamental material response, i.e. crack growth rate as a function of something. Currently, the technical community uses the stress intensity factor solution as a simplistic means to relate fatigue crack growth rate to loading, geometry and all other variables. The stress intensity factor solution is a very simple linear-elastic representation of the continuum mechanics portion of crack growth. In this paper, the authors present fatigue crack growth rate data for two different high strength steel alloys generated using standard methods. The steels exhibit behaviour that appears unexplainable, compared to an aluminium alloy presented as a baseline for comparison, using the stress intensity factor solution.
A Kalman Filter Based Technique for Stator Turn-Fault Detection of the Induction Motors
NASA Astrophysics Data System (ADS)
Ghanbari, Teymoor; Samet, Haidar
2017-11-01
Monitoring of the Induction Motors (IMs) through stator current for different faults diagnosis has considerable economic and technical advantages in comparison with the other techniques in this content. Among different faults of an IM, stator and bearing faults are more probable types, which can be detected by analyzing signatures of the stator currents. One of the most reliable indicators for fault detection of IMs is lower sidebands of power frequency in the stator currents. This paper deals with a novel simple technique for detecting stator turn-fault of the IMs. Frequencies of the lower sidebands are determined using the motor specifications and their amplitudes are estimated by a Kalman Filter (KF). Instantaneous Total Harmonic Distortion (ITHD) of these harmonics is calculated. Since variation of the ITHD for the three-phase currents is considerable in case of stator turn-fault, the fault can be detected using this criterion, confidently. Different simulation results verify high performance of the proposed method. The performance of the method is also confirmed using some experiments.
Guidelines for preparing software user documentation
NASA Technical Reports Server (NTRS)
Miller, Diane F.
1987-01-01
Clear, easy-to-use software user's manuals make strong demands on special technical communication techniques. Principles and guidelines are given for analyzing the audience and dealing with wide-ranging backgrounds of potential users. Types of information to be included in a complete manual are suggested, with a technique for creating a user-oriented rather than process-oriented organization. Accuracy verification is emphasized. Simple tips are gievn for formatting for quick comprehension and reference, for deciding on packaging, for creating helpful illustrations and examples, and for setting up clear and consistent conventions. Simple guidelines are offered for writing clearly and concisely and for editing.
Modeling the stylized facts in finance through simple nonlinear adaptive systems
Hommes, Cars H.
2002-01-01
Recent work on adaptive systems for modeling financial markets is discussed. Financial markets are viewed as evolutionary systems between different, competing trading strategies. Agents are boundedly rational in the sense that they tend to follow strategies that have performed well, according to realized profits or accumulated wealth, in the recent past. Simple technical trading rules may survive evolutionary competition in a heterogeneous world where prices and beliefs co-evolve over time. Evolutionary models can explain important stylized facts, such as fat tails, clustered volatility, and long memory, of real financial series. PMID:12011401
Management of Laryngoceles by Transoral Robotic Approach.
Kayhan, Fatma Tülin; Güneş, Selçuk; Koç, Arzu Karaman; Yiğider, Ayşe Pelin; Kaya, Kamil Hakan
2016-06-01
Laryngoceles are air-filled sacs which communicate with the laryngeal lumen. When filled with mucus or pus, they are called laryngomucoceles and laryngopyoceles, respectively. Transoral robotic surgery (TORS) is a new and remarkable technique that expands its usefullness in otorhinolaryngology. Conventional treatments for laryngoceles were previously performed using external approaches, with aesthetically unfavorable and less function-sparing results. Transoral laser microsurgical approaches for laryngoceles were seldom reported. It is aimed to present authors' clinical experience on laryngocele management with TORS which is a rather new technique. A retrospective patient serial. Patients were evaluated for demographic data, type of lesion, reasons for hospital admittance, complaint duration, and previous surgery. Robotic surgery panel including anesthesia time, duration of surgery, need for tracheotomy, postoperative care, follow-up, and recurrence rates were also summarized. Six men (mean age 51.7 years; range 41-62) with laryngoceles underwent successful TORS. Dyspnea and hoarseness were the main complaints. Two patients had undergone previous laryngeal surgery due to laryngeal cancer, with no recurrence of malignancy at admittance for laryngocele. Three had simple laryngocele, 2 had laryngomucocele, and 1 had laryngopyocele. No laryngoceles recurred and no complication such as dysphonia or prolonged dysphagia occurred. Transoral robotic surgery was found superior in safety, technical feasibility and curative effectiveness, when compared with classical methods, especially due to absence of skin incisions. Surgical modalities for laryngocele excision should be directed toward a curative target including cosmetic and functional success, technical achievability, and surgically curative methods. Transoral robotic surgery provided all these features.
Military Curriculum Materials for Vocational and Technical Education. Drainage, 3-5.
ERIC Educational Resources Information Center
Ohio State Univ., Columbus. National Center for Research in Vocational Education.
This individualized, self-paced course for independent study in water drainage was adapted from military curriculum materials for use in vocational education. The course provides basic information for the design of simple drainage structures for roads and airfields. Some job skills included are designing and constructing ditches and culverts;…
Measuring Student and School Progress with the California API. CSE Technical Report.
ERIC Educational Resources Information Center
Thum, Yeow Meng
This paper focuses on interpreting the major conceptual features of California's Academic Performance Index (API) as a coherent set of statistical procedures. To facilitate a characterization of its statistical properties, the paper casts the index as a simple weighted average of the subjective worth of students' normative performance and presents…
SIMON: A Simple Instructional Monitor. Technical Report.
ERIC Educational Resources Information Center
Feurzeig, Wallace; And Others
An instructional monitor is a program which tries to detect, diagnose, and possibly help overcome a student's learning difficulties in the course of solving a problem or performing a task. In one approach to building an instructional monitor, the student uses a special task- or problem-oriented language expressly designed around some particular…
Simple Detection-Performance Analysis of Multistatic Sonar for Anti-Submarine Warfare
2011-06-01
Following Urick [29], we take n = 8 dB. Since transmission loss contributes linearly (in dB units) to signal excess, allowance for absorption...sonobuoy fields for area search’, technical report DSTO-TR-2563 of the Defence Science and Technology Organisation. [29] R.J. Urick (1983) Principles of
What Does an IRR (or Two) Mean?
ERIC Educational Resources Information Center
Johnstone, David
2008-01-01
Defined mathematically, the internal rate of return (IRR) of a cash-flow stream is the discount rate at which its net present value is 0. What is the significance or meaning of such a measure? Using simple example problems and illustrative calculations, the author explains a technically correct but, at the same time, intuitively meaningful…
External Video for the Macintosh. Microcomputing Working Paper Series.
ERIC Educational Resources Information Center
Drexel Univ., Philadelphia, PA. Microcomputing Program.
This paper offers technical information on implementing external video capability on the Apple Macintosh Computer, which has no simple provisions for implementing this type of capability because it uses a non-standard horizontal line rate of 22.35KHz and lacks protection against the emission of RFI (radio frequency interference). The information…
ERIC Educational Resources Information Center
Reese, Susan
2012-01-01
Who are the adult students in career and technical education (CTE) today? There is not one simple answer to that question. Some are young with little life experience, while others are returning to the workforce and learning new skills to reinvent themselves. Whatever the case, educating adult students is an integral part of ACTE's mission, and the…
Improving Course Completions in Distance Education: An Institutional Case Study
ERIC Educational Resources Information Center
Thistoll, Tony; Yates, Anne
2016-01-01
This article reports two studies undertaken at The Open Polytechnic of New Zealand, a vocational distance education (DE) provider, where course completion rates have risen to match those of face-to-face technical institutions. A simple model of student engagement is presented, which reflects the triality between the student, institution, and…
ERIC Educational Resources Information Center
Kelleher, John
2013-01-01
This article describes John Kelleher's experience in observing the creations of his preschool daughter. Both he and his wife are formally trained in the arts, and looked forward to guiding their daughter down an artistic path. In his mind, what makes a great artist usually involves a great deal of technical ability and commitment to a complex…
A Teaching Artist in Rural Schools: Sowing Seeds for Creative Expression
ERIC Educational Resources Information Center
Kuper, Kate
2006-01-01
For nearly 25 years, the author has driven the highways and back roads of Illinois, teaching dance to school children, leading family programs, performing lecture/demonstrations, and choreographing technically simple, conceptually complex pieces with and for young dancers. The author's home base is Champaign/Urbana (C/U), twin cities with a…
A Web-Based Tutor for Java™: Evidence of Meaningful Learning
ERIC Educational Resources Information Center
Emurian, Henry H.
2006-01-01
Students in a graduate class and an undergraduate class in Information Systems completed a Web-based programmed instruction tutor that taught a simple Java applet as the first technical training exercise in a computer programming course. The tutor is a competency-based instructional system for individualized distance learning. When a student…
Industrial Prep, Volume Four, Junior Year--Contents: Mathematics and Guidance.
ERIC Educational Resources Information Center
Hackensack Public Schools, NJ.
As part of a 3-year comprehensive interdisciplinary program in industrial preparation for vocational students, this 11th Grade teaching guide consists of units on technical mathematics and guidance. Designed as supportive material for related physics and English curriculums, the first four sections of Volume 4 on algebra, vectors, simple machines,…
Toward Intelligent Systems for Testing. Technical Report LSP-1.
ERIC Educational Resources Information Center
Lesgold, Alan; And Others
This report illustrates one way in which the technologies of testing might combine with cognitive science techniques to help steer instruction. Steering testing is brief diagnostic testing that steers, or individualizes, the course of instruction. Steering testing uses simple heuristics for reasoning about the level of a student's competence in a…
Natural cellulose fibers from soybean straw.
Reddy, Narendra; Yang, Yiqi
2009-07-01
This paper reports the development of natural cellulose technical fibers from soybean straw with properties similar to the natural cellulose fibers in current use. About 220 million tons of soybean straw available in the world every year could complement the byproducts of other major food crops as inexpensive, abundant and annually renewable sources for natural cellulose fibers. Using the agricultural byproducts as sources for fibers could help to address the concerns on the future price and availability of both the natural and synthetic fibers in current use and also help to add value to the food crops. A simple alkaline extraction was used to obtain technical fibers from soybean straw and the composition, structure and properties of the fibers was studied. Technical fibers obtained from soybean straw have high cellulose content (85%) but low% crystallinity (47%). The technical fibers have breaking tenacity (2.7 g/den) and breaking elongation (3.9%) higher than those of fibers obtained from wheat straw and sorghum stalk and leaves but lower than that of cotton. Overall, the structure and properties of the technical fibers obtained from soybean straw indicates that the fibers could be suitable for use in textile, composite and other industrial applications.
Bioinspiration: something for everyone
Whitesides, George M.
2015-01-01
‘Bioinspiration’—using phenomena in biology to stimulate research in non-biological science and technology—is a strategy that suggests new areas for research. Beyond its potential to nucleate new ideas, bioinspiration has two other interesting characteristics. It can suggest subjects in research that are relatively simple technically; it can also lead to areas in which results can lead to useful function more directly than some of the more familiar areas now fashionable in chemistry. Bioinspired research thus has the potential to be accessible to laboratories that have limited resources, to offer routes to new and useful function, and to bridge differences in technical and cultural interactions of different geographical regions. PMID:26464790
Bishop, Felicity L
2015-02-01
To outline some of the challenges of mixed methods research and illustrate how they can be addressed in health psychology research. This study critically reflects on the author's previously published mixed methods research and discusses the philosophical and technical challenges of mixed methods, grounding the discussion in a brief review of methodological literature. Mixed methods research is characterized as having philosophical and technical challenges; the former can be addressed by drawing on pragmatism, the latter by considering formal mixed methods research designs proposed in a number of design typologies. There are important differences among the design typologies which provide diverse examples of designs that health psychologists can adapt for their own mixed methods research. There are also similarities; in particular, many typologies explicitly orient to the technical challenges of deciding on the respective timing of qualitative and quantitative methods and the relative emphasis placed on each method. Characteristics, strengths, and limitations of different sequential and concurrent designs are identified by reviewing five mixed methods projects each conducted for a different purpose. Adapting formal mixed methods designs can help health psychologists address the technical challenges of mixed methods research and identify the approach that best fits the research questions and purpose. This does not obfuscate the need to address philosophical challenges of mixing qualitative and quantitative methods. Statement of contribution What is already known on this subject? Mixed methods research poses philosophical and technical challenges. Pragmatism in a popular approach to the philosophical challenges while diverse typologies of mixed methods designs can help address the technical challenges. Examples of mixed methods research can be hard to locate when component studies from mixed methods projects are published separately. What does this study add? Critical reflections on the author's previously published mixed methods research illustrate how a range of different mixed methods designs can be adapted and applied to address health psychology research questions. The philosophical and technical challenges of mixed methods research should be considered together and in relation to the broader purpose of the research. © 2014 The British Psychological Society.
Validation of Body Volume Acquisition by Using Elliptical Zone Method.
Chiu, C-Y; Pease, D L; Fawkner, S; Sanders, R H
2016-12-01
The elliptical zone method (E-Zone) can be used to obtain reliable body volume data including total body volume and segmental volumes with inexpensive and portable equipment. The purpose of this research was to assess the accuracy of body volume data obtained from E-Zone by comparing them with those acquired from the 3D photonic scanning method (3DPS). 17 male participants with diverse somatotypes were recruited. Each participant was scanned twice on the same day by a 3D whole-body scanner and photographed twice for the E-Zone analysis. The body volume data acquired from 3DPS was regarded as the reference against which the accuracy of the E-Zone was assessed. The relative technical error of measurement (TEM) of total body volume estimations was around 3% for E-Zone. E-Zone can estimate the segmental volumes of upper torso, lower torso, thigh, shank, upper arm and lower arm accurately (relative TEM<10%) but the accuracy for small segments including the neck, hand and foot were poor. In summary, E-Zone provides a reliable, inexpensive, portable, and simple method to obtain reasonable estimates of total body volume and to indicate segmental volume distribution. © Georg Thieme Verlag KG Stuttgart · New York.
Sun, Bing; Zheng, Yun-Ling
2018-01-01
Currently there is no sensitive, precise, and reproducible method to quantitate alternative splicing of mRNA transcripts. Droplet digital™ PCR (ddPCR™) analysis allows for accurate digital counting for quantification of gene expression. Human telomerase reverse transcriptase (hTERT) is one of the essential components required for telomerase activity and for the maintenance of telomeres. Several alternatively spliced forms of hTERT mRNA in human primary and tumor cells have been reported in the literature. Using one pair of primers and two probes for hTERT, four alternatively spliced forms of hTERT (α-/β+, α+/β- single deletions, α-/β- double deletion, and nondeletion α+/β+) were accurately quantified through a novel analysis method via data collected from a single ddPCR reaction. In this chapter, we describe this ddPCR method that enables direct quantitative comparison of four alternatively spliced forms of the hTERT messenger RNA without the need for internal standards or multiple pairs of primers specific for each variant, eliminating the technical variation due to differential PCR amplification efficiency for different amplicons and the challenges of quantification using standard curves. This simple and straightforward method should have general utility for quantifying alternatively spliced gene transcripts.
Nitrogen implantation with a scanning electron microscope.
Becker, S; Raatz, N; Jankuhn, St; John, R; Meijer, J
2018-01-08
Established techniques for ion implantation rely on technically advanced and costly machines like particle accelerators that only few research groups possess. We report here about a new and surprisingly simple ion implantation method that is based upon a widespread laboratory instrument: The scanning electron microscope. We show that it can be utilized to ionize atoms and molecules from the restgas by collisions with electrons of the beam and subsequently accelerate and implant them into an insulating sample by the effect of a potential building up at the sample surface. Our method is demonstrated by the implantation of nitrogen ions into diamond and their subsequent conversion to nitrogen vacancy centres which can be easily measured by fluorescence confocal microscopy. To provide evidence that the observed centres are truly generated in the way we describe, we supplied a 98% isotopically enriched 15 N gas to the chamber, whose natural abundance is very low. By employing the method of optically detected magnetic resonance, we were thus able to verify that the investigated centres are actually created from the 15 N isotopes. We also show that this method is compatible with lithography techniques using e-beam resist, as demonstrated by the implantation of lines using PMMA.
Machine Learning Approaches in Cardiovascular Imaging.
Henglin, Mir; Stein, Gillian; Hushcha, Pavel V; Snoek, Jasper; Wiltschko, Alexander B; Cheng, Susan
2017-10-01
Cardiovascular imaging technologies continue to increase in their capacity to capture and store large quantities of data. Modern computational methods, developed in the field of machine learning, offer new approaches to leveraging the growing volume of imaging data available for analyses. Machine learning methods can now address data-related problems ranging from simple analytic queries of existing measurement data to the more complex challenges involved in analyzing raw images. To date, machine learning has been used in 2 broad and highly interconnected areas: automation of tasks that might otherwise be performed by a human and generation of clinically important new knowledge. Most cardiovascular imaging studies have focused on task-oriented problems, but more studies involving algorithms aimed at generating new clinical insights are emerging. Continued expansion in the size and dimensionality of cardiovascular imaging databases is driving strong interest in applying powerful deep learning methods, in particular, to analyze these data. Overall, the most effective approaches will require an investment in the resources needed to appropriately prepare such large data sets for analyses. Notwithstanding current technical and logistical challenges, machine learning and especially deep learning methods have much to offer and will substantially impact the future practice and science of cardiovascular imaging. © 2017 American Heart Association, Inc.
Improvements to direct quantitative analysis of multiple microRNAs facilitating faster analysis.
Ghasemi, Farhad; Wegman, David W; Kanoatov, Mirzo; Yang, Burton B; Liu, Stanley K; Yousef, George M; Krylov, Sergey N
2013-11-05
Studies suggest that patterns of deregulation in sets of microRNA (miRNA) can be used as cancer diagnostic and prognostic biomarkers. Establishing a "miRNA fingerprint"-based diagnostic technique requires a suitable miRNA quantitation method. The appropriate method must be direct, sensitive, capable of simultaneous analysis of multiple miRNAs, rapid, and robust. Direct quantitative analysis of multiple microRNAs (DQAMmiR) is a recently introduced capillary electrophoresis-based hybridization assay that satisfies most of these criteria. Previous implementations of the method suffered, however, from slow analysis time and required lengthy and stringent purification of hybridization probes. Here, we introduce a set of critical improvements to DQAMmiR that address these technical limitations. First, we have devised an efficient purification procedure that achieves the required purity of the hybridization probe in a fast and simple fashion. Second, we have optimized the concentrations of the DNA probe to decrease the hybridization time to 10 min. Lastly, we have demonstrated that the increased probe concentrations and decreased incubation time removed the need for masking DNA, further simplifying the method and increasing its robustness. The presented improvements bring DQAMmiR closer to use in a clinical setting.
Gaikwad, Ravi M; Dokukin, Maxim E; Iyer, K Swaminathan; Woodworth, Craig D; Volkov, Dmytro O; Sokolov, Igor
2011-04-07
Here we describe a non-traditional method to identify cancerous human cervical epithelial cells in a culture dish based on physical adhesion between silica beads and cells. It is a simple optical fluorescence-based technique which detects the relative difference in the amount of fluorescent silica beads physically adherent to surfaces of cancerous and normal cervical cells. The method utilizes the centripetal force gradient that occurs in a rotating culture dish. Due to the variation in the balance between adhesion and centripetal forces, cancerous and normal cells demonstrate clearly distinctive distributions of the fluorescent particles adherent to the cell surface over the culture dish. The method demonstrates higher adhesion of silica particles to normal cells compared to cancerous cells. The difference in adhesion was initially observed by atomic force microscopy (AFM). The AFM data were used to design the parameters of the rotational dish experiment. The optical method that we describe is much faster and technically simpler than AFM. This work provides proof of the concept that physical interactions can be used to accurately discriminate normal and cancer cells. © The Royal Society of Chemistry 2011
In vivo neuronal calcium imaging in C. elegans.
Chung, Samuel H; Sun, Lin; Gabel, Christopher V
2013-04-10
The nematode worm C. elegans is an ideal model organism for relatively simple, low cost neuronal imaging in vivo. Its small transparent body and simple, well-characterized nervous system allows identification and fluorescence imaging of any neuron within the intact animal. Simple immobilization techniques with minimal impact on the animal's physiology allow extended time-lapse imaging. The development of genetically-encoded calcium sensitive fluorophores such as cameleon and GCaMP allow in vivo imaging of neuronal calcium relating both cell physiology and neuronal activity. Numerous transgenic strains expressing these fluorophores in specific neurons are readily available or can be constructed using well-established techniques. Here, we describe detailed procedures for measuring calcium dynamics within a single neuron in vivo using both GCaMP and cameleon. We discuss advantages and disadvantages of both as well as various methods of sample preparation (animal immobilization) and image analysis. Finally, we present results from two experiments: 1) Using GCaMP to measure the sensory response of a specific neuron to an external electrical field and 2) Using cameleon to measure the physiological calcium response of a neuron to traumatic laser damage. Calcium imaging techniques such as these are used extensively in C. elegans and have been extended to measurements in freely moving animals, multiple neurons simultaneously and comparison across genetic backgrounds. C. elegans presents a robust and flexible system for in vivo neuronal imaging with advantages over other model systems in technical simplicity and cost.
Nuchtavorn, Nantana; Macka, Mirek
2016-05-05
Paper-based microfluidic devices (μPADs) are capable of achieving rapid quantitative measurements of a variety of analytes inexpensively. μPADs rely on patterning hydrophilic-hydrophobic regions on a sheet of paper in order to create capillary channels within impermeable fluidic brakes on the paper. Here, we present a novel, highly flexible and low-cost fabrication method using a desktop digital craft plotter/cutter and technical drawing pens with tip size of 0.5 mm. The pens were used with either commercial black permanent ink for drawing fluidic brakes, or with specialty in-house formulated aqueous inks. With the permanent marker ink it was possible to create barriers on paper rapidly and in a variety of designs in a highly flexible manner. For instance, a design featuring eight reservoirs can be produced within 10 s for each μPAD with a consistent line width of brakes (%RSD < 1.5). Further, we investigated the optimal viscosity range of in-house formulated inks controlled with additions of poly(ethylene glycol). The viscosity was measured by capillary electrophoresis and the optimal viscosity was in the range of ∼3-6 mPa s. A functional test of these μPADs was conducted by the screening of antioxidant activity. Colorimetric measurements of flavonoid, phenolic compounds and DPPH free radical scavenging activity were carried out on μPADs. The results can be detected by the naked eye and simply quantified by using a camera phone and image analysis software. The fabrication method using technical drawing pens provides flexibility in the use of in-house formulated inks, short fabrication time, simplicity and low cost. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.
TriatoKey: a web and mobile tool for biodiversity identification of Brazilian triatomine species
Márcia de Oliveira, Luciana; Nogueira de Brito, Raissa; Anderson Souza Guimarães, Paul; Vitor Mastrângelo Amaro dos Santos, Rômulo; Gonçalves Diotaiuti, Liléia; de Cássia Moreira de Souza, Rita
2017-01-01
Abstract Triatomines are blood-sucking insects that transmit the causative agent of Chagas disease, Trypanosoma cruzi. Despite being recognized as a difficult task, the correct taxonomic identification of triatomine species is crucial for vector control in Latin America, where the disease is endemic. In this context, we have developed a web and mobile tool based on PostgreSQL database to help healthcare technicians to overcome the difficulties to identify triatomine vectors when the technical expertise is missing. The web and mobile version makes use of real triatomine species pictures and dichotomous key method to support the identification of potential vectors that occur in Brazil. It provides a user example-driven interface with simple language. TriatoKey can also be useful for educational purposes. Database URL: http://triatokey.cpqrr.fiocruz.br PMID:28605769
Advantages and disadvantages of endoscopically assisted front-lift.
Dusková, M; Padĕra, J; Kristen, M
2002-01-01
Reduced surgical risk, a diminution of visible scars, rapid recovery, long-termed results and reduced costs are at present the most important demands on development in aesthetic plastic surgery. Endoscopically assisted front-lift meets perfectly the need of reduced invasiveness. It is technically simple and associated with a minimum of complications. It brings minimal scars beyond the hairline with a favourable effect after eliminating the drop of the brows, and wrinkles on the forehead. The duration of the effect in the aging face depends, however, similarly as other methods, on the characteristics of the skin, changes in other parts and the individual disposition. A marked disadvantage is the high initial, cost of special equipment. Their recovery ensues from the reduced time of surgery, reduced consumption of material, lower number of complications and more rapid return to normal life.
Authentication, Time-Stamping and Digital Signatures
NASA Technical Reports Server (NTRS)
Levine, Judah
1996-01-01
Time and frequency data are often transmitted over public packet-switched networks, and the use of this mode of distribution is likely to increase in the near future as high-speed logical circuits transmitted via networks replace point-to-point physical circuits. ALthough these networks have many technical advantages, they are susceptible to evesdropping, spoofing, and the alteration of messages enroute using techniques that are relatively simple to implement and quite difficult to detect. I will discuss a number of solutions to these problems, including the authentication mechanism used in the Network Time Protocol (NTP) and the more general technique of signing time-stamps using public key cryptography. This public key method can also be used to implement the digital analog of a Notary Public, and I will discuss how such a system could be realized on a public network such as the Internet.
The use of phosphatidylcholine for correction of localized fat deposits.
Rittes, Patrícia Guedes
2003-01-01
Subjects with localized fat deposits commonly receive suction lipectomy as a cosmetic procedure. A new office procedure for correction of those superficial fat deposits was applied in 50 patients by injection of phosphatidylcholine. The method itself consists of using a 3OG1/2 insulin needle to inject about 5 ml (250 mg/5 ml) of phosphatidylcholine into the fat, distributing it evenly in an 80 cm2 area. Pre- and posttreatment photographs were taken for technical planning and analysis of the results over the long term. A clear improvement occurred in all, with a marked reduction of the fat deposits without recurrence over a 2-year follow-up period and no weight gain. The injection of phosphatidylcholine into the fat deposits is a simple office procedure that can sometimes postpone or even replace surgery and liposuction.
Wu, Xian; Fan, Lishuang; Qiu, Yue; Wang, Maoxu; Cheng, Junhan; Guan, Bin; Guo, Zhikun; Zhang, Naiqing; Sun, Kening
2018-06-26
Lithium sulfur batteries have been restricted on their major technical problem of shuttling soluble polysulfides between electrodes, resulting in serious capacity fading. For purpose of develop a high-performance lithium-sulfur battery, we first time utilize a simple growth method to introduce a Prussian blue modified Celgard separator as an ion selective membrane in lithium sulfur batteries. The unique structure of Prussian blue could effectively suppress the shuttle of polysulfides but scarcely affect the transfer ability of lithium ions, which is beneficial to achieve high sulfur conversion efficiency and capacity retention. The lithium sulfur battery with Prussian blue modified Celgard separator reveals an average capacity decaying of only 0.03% per cycle at 1C after 1000 cycles. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Correlators in tensor models from character calculus
NASA Astrophysics Data System (ADS)
Mironov, A.; Morozov, A.
2017-11-01
We explain how the calculations of [20], which provided the first evidence for non-trivial structures of Gaussian correlators in tensor models, are efficiently performed with the help of the (Hurwitz) character calculus. This emphasizes a close similarity between technical methods in matrix and tensor models and supports a hope to understand the emerging structures in very similar terms. We claim that the 2m-fold Gaussian correlators of rank r tensors are given by r-linear combinations of dimensions with the Young diagrams of size m. The coefficients are made from the characters of the symmetric group Sm and their exact form depends on the choice of the correlator and on the symmetries of the model. As the simplest application of this new knowledge, we provide simple expressions for correlators in the Aristotelian tensor model as tri-linear combinations of dimensions.
Particle image velocimetry based on wavelength division multiplexing
NASA Astrophysics Data System (ADS)
Tang, Chunxiao; Li, Enbang; Li, Hongqiang
2018-01-01
This paper introduces a technical approach of wavelength division multiplexing (WDM) based particle image velocimetry (PIV). It is designed to measure transient flows with different scales of velocity by capturing multiple particle images in one exposure. These images are separated by different wavelengths, and thus the pulse separation time is not influenced by the frame rate of the camera. A triple-pulsed PIV system has been created in order to prove the feasibility of WDM-PIV. This is demonstrated in a sieve plate extraction column model by simultaneously measuring the fast flow in the downcomer and the slow vortices inside the plates. A simple displacement/velocity field combination method has also been developed. The constraints imposed by WDM-PIV are limited wavelength choices of available light sources and cameras. The usage of WDM technique represents a feasible way to realize multiple-pulsed PIV.
Waller, Niels
2018-01-01
Kristof's Theorem (Kristof, 1970 ) describes a matrix trace inequality that can be used to solve a wide-class of least-square optimization problems without calculus. Considering its generality, it is surprising that Kristof's Theorem is rarely used in statistics and psychometric applications. The underutilization of this method likely stems, in part, from the mathematical complexity of Kristof's ( 1964 , 1970 ) writings. In this article, I describe the underlying logic of Kristof's Theorem in simple terms by reviewing four key mathematical ideas that are used in the theorem's proof. I then show how Kristof's Theorem can be used to provide novel derivations to two cognate models from statistics and psychometrics. This tutorial includes a glossary of technical terms and an online supplement with R (R Core Team, 2017 ) code to perform the calculations described in the text.
Characterization of technical surfaces by structure function analysis
NASA Astrophysics Data System (ADS)
Kalms, Michael; Kreis, Thomas; Bergmann, Ralf B.
2018-03-01
The structure function is a tool for characterizing technical surfaces that exhibits a number of advantages over Fourierbased analysis methods. So it is optimally suited for analyzing the height distributions of surfaces measured by full-field non-contacting methods. The structure function is thus a useful method to extract global or local criteria like e. g. periodicities, waviness, lay, or roughness to analyze and evaluate technical surfaces. After the definition of line- and area-structure function and offering effective procedures for their calculation this paper presents examples using simulated and measured data of technical surfaces including aircraft parts.
The Taguchi Method Application to Improve the Quality of a Sustainable Process
NASA Astrophysics Data System (ADS)
Titu, A. M.; Sandu, A. V.; Pop, A. B.; Titu, S.; Ciungu, T. C.
2018-06-01
Taguchi’s method has always been a method used to improve the quality of the analyzed processes and products. This research shows an unusual situation, namely the modeling of some parameters, considered technical parameters, in a process that is wanted to be durable by improving the quality process and by ensuring quality using an experimental research method. Modern experimental techniques can be applied in any field and this study reflects the benefits of interacting between the agriculture sustainability principles and the Taguchi’s Method application. The experimental method used in this practical study consists of combining engineering techniques with experimental statistical modeling to achieve rapid improvement of quality costs, in fact seeking optimization at the level of existing processes and the main technical parameters. The paper is actually a purely technical research that promotes a technical experiment using the Taguchi method, considered to be an effective method since it allows for rapid achievement of 70 to 90% of the desired optimization of the technical parameters. The missing 10 to 30 percent can be obtained with one or two complementary experiments, limited to 2 to 4 technical parameters that are considered to be the most influential. Applying the Taguchi’s Method in the technique and not only, allowed the simultaneous study in the same experiment of the influence factors considered to be the most important in different combinations and, at the same time, determining each factor contribution.
Yasukawa, Keiko; Shimosawa, Tatsuo; Okubo, Shigeo; Yatomi, Yutaka
2018-01-01
Background Human mercaptalbumin and human non-mercaptalbumin have been reported as markers for various pathological conditions, such as kidney and liver diseases. These markers play important roles in redox regulations throughout the body. Despite the recognition of these markers in various pathophysiologic conditions, the measurements of human mercaptalbumin and non-mercaptalbumin have not been popular because of the technical complexity and long measurement time of conventional methods. Methods Based on previous reports, we explored the optimal analytical conditions for a high-performance liquid chromatography method using an anion-exchange column packed with a hydrophilic polyvinyl alcohol gel. The method was then validated using performance tests as well as measurements of various patients' serum samples. Results We successfully established a reliable high-performance liquid chromatography method with an analytical time of only 12 min per test. The repeatability (within-day variability) and reproducibility (day-to-day variability) were 0.30% and 0.27% (CV), respectively. A very good correlation was obtained with the results of the conventional method. Conclusions A practical method for the clinical measurement of human mercaptalbumin and non-mercaptalbumin was established. This high-performance liquid chromatography method is expected to be a powerful tool enabling the expansion of clinical usefulness and ensuring the elucidation of the roles of albumin in redox reactions throughout the human body.
American Thyroid Association Statement on Remote-Access Thyroid Surgery
Bernet, Victor; Fahey, Thomas J.; Kebebew, Electron; Shaha, Ashok; Stack, Brendan C.; Stang, Michael; Steward, David L.; Terris, David J.
2016-01-01
Background: Remote-access techniques have been described over the recent years as a method of removing the thyroid gland without an incision in the neck. However, there is confusion related to the number of techniques available and the ideal patient selection criteria for a given technique. The aims of this review were to develop a simple classification of these approaches, describe the optimal patient selection criteria, evaluate the outcomes objectively, and define the barriers to adoption. Methods: A review of the literature was performed to identify the described techniques. A simple classification was developed. Technical details, outcomes, and the learning curve were described. Expert opinion consensus was formulated regarding recommendations for patient selection and performance of remote-access thyroid surgery. Results: Remote-access thyroid procedures can be categorized into endoscopic or robotic breast, bilateral axillo-breast, axillary, and facelift approaches. The experience in the United States involves the latter two techniques. The limited data in the literature suggest long operative times, a steep learning curve, and higher costs with remote-access thyroid surgery compared with conventional thyroidectomy. Nevertheless, a consensus was reached that, in appropriate hands, it can be a viable option for patients with unilateral small nodules who wish to avoid a neck incision. Conclusions: Remote-access thyroidectomy has a role in a small group of patients who fit strict selection criteria. These approaches require an additional level of expertise, and therefore should be done by surgeons performing a high volume of thyroid and robotic surgery. PMID:26858014
DOE Office of Scientific and Technical Information (OSTI.GOV)
Janssen, H., E-mail: hendrik.janssen@med.uni-muenchen.de; Buchholz, G.; Killer, M.
PurposeWhile today mechanical thrombectomy is an established treatment option for main branch occlusions in anterior circulation stroke, there is still an ongoing debate on the kind of anesthesia to be preferred. Introducing a simple method for head stabilization, we analyzed safety and duration of endovascular recanalization procedures under general anesthesia (GA) and conscious sedation (CS).MethodsWe retrospectively identified 84 consecutive patients who underwent mechanical thrombectomy owing to acute anterior circulation stroke. Fifty-three were treated under GA and 31 under CS equipped with a standard cervical collar to reduce head movement. We evaluated recanalization results, in-house time to start recanalization, procedure times,more » technical and clinical complication rates, and conversion rates from CS to GA.ResultsRecanalization of mTICI ≥2b was achieved in 80 % under CS and in 81 % under GA. Median in-house time to start recanalization for CS was 60 min (IQR 28; 44–72) and 77 min (IQR 23; 68–91) for GA (P = 0.001). Median procedure time under CS was 35 min (IQR 43; 69–25) and 41 min (IQR 43; 66–23) for GA (P = 0.9). No major complications such as ICH occurred in either group, and no conversions from CS to GA were necessary.ConclusionMechanical thrombectomy can be performed faster and safely under CS in combination with simple head immobilization using a standard cervical collar.« less
A phylogenetic Kalman filter for ancestral trait reconstruction using molecular data.
Lartillot, Nicolas
2014-02-15
Correlation between life history or ecological traits and genomic features such as nucleotide or amino acid composition can be used for reconstructing the evolutionary history of the traits of interest along phylogenies. Thus far, however, such ancestral reconstructions have been done using simple linear regression approaches that do not account for phylogenetic inertia. These reconstructions could instead be seen as a genuine comparative regression problem, such as formalized by classical generalized least-square comparative methods, in which the trait of interest and the molecular predictor are represented as correlated Brownian characters coevolving along the phylogeny. Here, a Bayesian sampler is introduced, representing an alternative and more efficient algorithmic solution to this comparative regression problem, compared with currently existing generalized least-square approaches. Technically, ancestral trait reconstruction based on a molecular predictor is shown to be formally equivalent to a phylogenetic Kalman filter problem, for which backward and forward recursions are developed and implemented in the context of a Markov chain Monte Carlo sampler. The comparative regression method results in more accurate reconstructions and a more faithful representation of uncertainty, compared with simple linear regression. Application to the reconstruction of the evolution of optimal growth temperature in Archaea, using GC composition in ribosomal RNA stems and amino acid composition of a sample of protein-coding genes, confirms previous findings, in particular, pointing to a hyperthermophilic ancestor for the kingdom. The program is freely available at www.phylobayes.org.
Detection and characterization of protein interactions in vivo by a simple live-cell imaging method.
Gallego, Oriol; Specht, Tanja; Brach, Thorsten; Kumar, Arun; Gavin, Anne-Claude; Kaksonen, Marko
2013-01-01
Over the last decades there has been an explosion of new methodologies to study protein complexes. However, most of the approaches currently used are based on in vitro assays (e.g. nuclear magnetic resonance, X-ray, electron microscopy, isothermal titration calorimetry etc). The accurate measurement of parameters that define protein complexes in a physiological context has been largely limited due to technical constrains. Here, we present PICT (Protein interactions from Imaging of Complexes after Translocation), a new method that provides a simple fluorescence microscopy readout for the study of protein complexes in living cells. We take advantage of the inducible dimerization of FK506-binding protein (FKBP) and FKBP-rapamycin binding (FRB) domain to translocate protein assemblies to membrane associated anchoring platforms in yeast. In this assay, GFP-tagged prey proteins interacting with the FRB-tagged bait will co-translocate to the FKBP-tagged anchor sites upon addition of rapamycin. The interactions are thus encoded into localization changes and can be detected by fluorescence live-cell imaging under different physiological conditions or upon perturbations. PICT can be automated for high-throughput studies and can be used to quantify dissociation rates of protein complexes in vivo. In this work we have used PICT to analyze protein-protein interactions from three biological pathways in the yeast Saccharomyces cerevisiae: Mitogen-activated protein kinase cascade (Ste5-Ste11-Ste50), exocytosis (exocyst complex) and endocytosis (Ede1-Syp1).
Li, Zhi; Tevis, Ian D; Oyola-Reynoso, Stephanie; Newcomb, Lucas B; Halbertsma-Black, Julian; Bloch, Jean-Francis; Thuo, Martin
2015-12-01
Interest in low-cost analytical devices (especially for diagnostics) has recently increased; however, concomitant translation to the field has been slow, in part due to personnel and supply-chain challenges in resource-limited settings. Overcoming some of these challenges require the development of a method that takes advantage of locally available resources and/or skills. We report a Melt-and-mold fabrication (MnM Fab) approach to low-cost and simple devices that has the potential to be adapted locally since it requires a single material that is recyclable and simple skills to access multiple devices. We demonstrated this potential by fabricating entry level bio-analytical devices using an affordable low-melting metal alloy, Field's metal, with molds produced from known materials such as plastic (acrylonitrile-butadiene-styrene (ABS)), glass, and paper. We fabricated optical gratings then 4×4 well plates using the same recycled piece of metal. We then reconfigured the well plates into rapid prototype microfluidic devices with which we demonstrated laminar flow, droplet generation, and bubble formation from T-shaped channels. We conclude that this MnM-Fab method is capable of addressing some challenges typically encountered with device translation, such as technical know-how or material supply, and that it can be applied to other devices, as needed in the field, using a single moldable material. Copyright © 2015 Elsevier B.V. All rights reserved.
Imada, Tatsuyuki; Kamibayashi, Takahiko; Ota, Chiho; Carl Shibata, Sho; Iritakenishi, Takeshi; Sawa, Yoshiki; Fujino, Yuji
2015-08-01
Intraoperative two-dimensional echocardiography is technically challenging, given the unique geometry of the right ventricle (RV). It was hypothesized that the RV fractional area change (RVFAC) could be used as a simple method to evaluate RV function during surgery. Therefore, the correlation between the intraoperative RVFAC and the true right ventricular ejection fraction (RVEF), as measured using newly developed three-dimensional (3D) analysis software, was evaluated. Retrospective study. University hospital. Patients who underwent cardiac surgery with transesophageal echocardiography monitoring between March 2014 and June 2014. None. Sixty-two patients were included in this study. After the exclusion of poor imaging data and patients with arrhythmias, 54 data sets were analyzed. RVFAC was measured by one anesthesiologist during surgery, and full-volume 3D echocardiographic data were recorded simultaneously. The 3D data were analyzed postoperatively using off-line 3D analysis software by a second anesthesiologist, who was blinded to the RVFAC results. The mean RVFAC was 38.8% ± 8.7%, the mean RVEF was 41.4% ± 8.3%, and there was a good correlation between the RVFAC and the RVEF (r(2) = 0.638; p<0.0001). The RVFAC was well-correlated with the RVEF calculated using 3D echocardiography; therefore, RVFAC provides a simple and useful method for anesthesiologists to evaluate intraoperative RV function. Copyright © 2015 Elsevier Inc. All rights reserved.
Using Corporate-Based Methods To Assess Technical Communication Programs.
ERIC Educational Resources Information Center
Faber, Brenton; Bekins, Linn; Karis, Bill
2002-01-01
Investigates methods of program assessment used by corporate learning sites and profiles value added methods as a way to both construct and evaluate academic programs in technical communication. Examines and critiques assessment methods from corporate training environments including methods employed by corporate universities and value added…
Efficient and Rapid Isolation of Early-stage Embryos from Arabidopsis thaliana Seeds
Raissig, Michael T.; Gagliardini, Valeria; Jaenisch, Johan; Grossniklaus, Ueli; Baroux, Célia
2013-01-01
In flowering plants, the embryo develops within a nourishing tissue - the endosperm - surrounded by the maternal seed integuments (or seed coat). As a consequence, the isolation of plant embryos at early stages (1 cell to globular stage) is technically challenging due to their relative inaccessibility. Efficient manual dissection at early stages is strongly impaired by the small size of young Arabidopsis seeds and the adhesiveness of the embryo to the surrounding tissues. Here, we describe a method that allows the efficient isolation of young Arabidopsis embryos, yielding up to 40 embryos in 1 hr to 4 hr, depending on the downstream application. Embryos are released into isolation buffer by slightly crushing 250-750 seeds with a plastic pestle in an Eppendorf tube. A glass microcapillary attached to either a standard laboratory pipette (via a rubber tube) or a hydraulically controlled microinjector is used to collect embryos from droplets placed on a multi-well slide on an inverted light microscope. The technical skills required are simple and easily transferable, and the basic setup does not require costly equipment. Collected embryos are suitable for a variety of downstream applications such as RT-PCR, RNA sequencing, DNA methylation analyses, fluorescence in situ hybridization (FISH), immunostaining, and reporter gene assays. PMID:23770918
Pollen--tiny and ephemeral but not forgotten: New ideas on their ecology and evolution.
Williams, Joseph H; Mazer, Susan J
2016-03-01
Ecologists and evolutionary biologists have been interested in the functional biology of pollen since the discovery in the 1800s that pollen grains encompass tiny plants (male gametophytes) that develop and produce sperm cells. After the discovery of double fertilization in flowering plants, botanists in the early 1900s were quick to explore the effects of temperature and maternal nutrients on pollen performance, while evolutionary biologists began studying the nature of haploid selection and pollen competition. A series of technical and theoretic developments have subsequently, but usually separately, expanded our knowledge of the nature of pollen performance and how it evolves. Today, there is a tremendous diversity of interests that touch on pollen performance, ranging from the ecological setting on the stigma, structural and physiological aspects of pollen germination and tube growth, the form of pollen competition and its role in sexual selection in plants, virus transmission, mating system evolution, and inbreeding depression. Given the explosion of technical knowledge of pollen cell biology, computer modeling, and new methods to deal with diversity in a phylogenetic context, we are now more than ever poised for a new era of research that includes complex functional traits that limit or enhance the evolution of these deceptively simple organisms. © 2016 Botanical Society of America.
Troubleshooting Microcomputers. A Technical Guide for Polk County Schools.
ERIC Educational Resources Information Center
Black, B. R.; And Others
This guide was started in 1986 as an effort to pull together a collection of several computer guides that had been written over the previous several years to assist schools in making simple computer repairs. The first of six sections contains general tips and hints, including sections on tool requirements, strobe disk speed adjustment, static…
The Technique of Film Animation. Revised Edition.
ERIC Educational Resources Information Center
Halas, John; Manvell, Roger
This book, which is a technical, sophisticated manual for professionals, covers all aspects of the animation process; it does not use a simple step-by-step, do-it-at-home approach. It begins by discussing the history of animation and the physical laws and aesthetic principles which govern the art. A section on the uses of animation (e.g., for…
TEACHING AND TRAINING WITH MOTION PICTURES (MAGNETIC SOUND).
ERIC Educational Resources Information Center
Bell and Howell Co., Lincolnwood, IL.
THE PREPARATION OF A MAGNETIC-SOUND TRACK FOR 16 MM. MOTION PICTURE FILMS IS DESCRIBED. IN SCRIPT PREPARATION, THE SCRIPT SHOULD BE WRITTEN IN NARRATIVE FORM TO INCLUDE ALL SHOTS NEEDED AND TO SUPPLEMENT AND GIVE INFORMATION NOT IN THE FILM. LANGUAGE SHOULD BE KEPT SIMPLE, AND UNAVOIDABLE TECHNICAL TERMS SHOULD BE EXPLAINED. IN REWRITING THE…
ERIC Educational Resources Information Center
New York State Education Dept., Albany. Bureau of Secondary Curriculum Development.
Designed to prepare students to be engine mechanics working on automotive and large stationary diesel engines, this instructor's guide contains eight units arranged from simple to complex to facilitate student learning. Each contains behavioral objectives, a content outline, understandings and teaching approaches necessary to develop the content,…
ERIC Educational Resources Information Center
Suppes, P.; And Others
From some simple and schematic assumptions about information processing, a stochastic differential equation is derived for the motion of a student through a computer-assisted elementary mathematics curriculum. The mathematics strands curriculum of the Institute for Mathematical Studies in the Social Sciences is used to test: (1) the theory and (2)…
Solar Cooling for Buildings. Workshop Proceedings (Los Angeles, California, February 6-8, 1974).
ERIC Educational Resources Information Center
de Winter, Francis, Ed.
A consensus has developed among U.S. solar researchers that the solar-powered cooling of buildings is an important topic. Most solar heating systems are technically simpler, and more highly developed, than solar cooling devices are. The determination of the best design concept for any particular application is not a simple process. Significant…
ERIC Educational Resources Information Center
Espin, Christine A.; Busch, Todd W.; Lembke, Erica S.; Hampton, David D.; Seo, Kyounghee; Zukowski, Beth A.
2013-01-01
The technical adequacy of curriculum-based measures in the form of short and simple vocabulary-matching probes to predict students' performance and progress in science at the secondary level was investigated. Participants were 198 seventh-grade students from 10 science classrooms. Curriculum-based measurements (CBM) were 5-min vocabulary-matching…
ERIC Educational Resources Information Center
Treurniet, William
A study applied artificial neural networks, trained with the back-propagation learning algorithm, to modelling phonemes extracted from the DARPA TIMIT multi-speaker, continuous speech data base. A number of proposed network architectures were applied to the phoneme classification task, ranging from the simple feedforward multilayer network to more…
The Effect of a Simple Simulation Game on Long-Term Vocabulary Retention
ERIC Educational Resources Information Center
Franciosi, Stephan J.; Yagi, Junichi; Tomoshige, Yuuki; Ye, Suying
2016-01-01
Recent studies have shown that simulation games may be useful tools for supporting foreign language education. However, much of this research has focused on games using 3D graphic technology, which entail technical requirements that may render them too complex for use in many educational contexts. Accordingly, we wanted to determine if less…
ERIC Educational Resources Information Center
Gibbons, Robert D.; And Others
In the process of developing a conditionally-dependent item response theory (IRT) model, the problem arose of modeling an underlying multivariate normal (MVN) response process with general correlation among the items. Without the assumption of conditional independence, for which the underlying MVN cdf takes on comparatively simple forms and can be…
NASA Technical Reports Server (NTRS)
Pinelli, Thomas E.; Glassman, Myron
1989-01-01
A pilot study was conducted to evaluate selected NASA scientific and technical information (STI) products. The study, which utilized survey research in the form of a self-administered mail questionnaire, had a two-fold purpose -- to gather baseline data regarding the use and perceived usefulness of selected NASA STI products and to develop/validate questions that could be used in a future study concerned with the role of the U.S. government technical report in aeronautics. The sample frame consisted of 25,000 members of the American Institute of Aeronautics and Astronautics in the U.S. with academic, government or industrial affiliation. Simple random sampling was used to select 2000 individuals to participate in the study. Three hundred fifty-three usable questionnaires (17 percent response rate) were received by the established cutoff date. The findings indicate that: (1) NASA STI is used and is generally perceived as being important; (2) the use rate for NASA-authored conference/meeting papers, journal articles, and technical reports is fairly uniform; (3) a considerable number of respondents are unfamiliar with STAR (Scientific and Technical Aerospace Reports), IAA (International Aerospace Abstracts), SCAN (Selected Current Aerospace Notices), and the RECON on-line retrieval system; (4) a considerable number of respondents who are familiar with these media do not use them; and (5) the perceived quality of NASA-authored journal articles and technical reports is very good.
Murphy, Thomas; Schwedock, Julie; Nguyen, Kham; Mills, Anna; Jones, David
2015-01-01
New recommendations for the validation of rapid microbiological methods have been included in the revised Technical Report 33 release from the PDA. The changes include a more comprehensive review of the statistical methods to be used to analyze data obtained during validation. This case study applies those statistical methods to accuracy, precision, ruggedness, and equivalence data obtained using a rapid microbiological methods system being evaluated for water bioburden testing. Results presented demonstrate that the statistical methods described in the PDA Technical Report 33 chapter can all be successfully applied to the rapid microbiological method data sets and gave the same interpretation for equivalence to the standard method. The rapid microbiological method was in general able to pass the requirements of PDA Technical Report 33, though the study shows that there can be occasional outlying results and that caution should be used when applying statistical methods to low average colony-forming unit values. Prior to use in a quality-controlled environment, any new method or technology has to be shown to work as designed by the manufacturer for the purpose required. For new rapid microbiological methods that detect and enumerate contaminating microorganisms, additional recommendations have been provided in the revised PDA Technical Report No. 33. The changes include a more comprehensive review of the statistical methods to be used to analyze data obtained during validation. This paper applies those statistical methods to analyze accuracy, precision, ruggedness, and equivalence data obtained using a rapid microbiological method system being validated for water bioburden testing. The case study demonstrates that the statistical methods described in the PDA Technical Report No. 33 chapter can be successfully applied to rapid microbiological method data sets and give the same comparability results for similarity or difference as the standard method. © PDA, Inc. 2015.
Innovative Additive for Bitumen Based on Processed Fats
NASA Astrophysics Data System (ADS)
Babiak, Michał; Kosno, Jacek; Ratajczak, Maria; Zieliński, Krzysztof
2017-10-01
Various additives, admixtures and modifiers are used to improve technical properties and strength characteristics of building materials. Manufacturers of waterproofing materials, concrete, ceramics and bitumen have to use innovative, increasingly complex and costly additives, admixtures or modifiers. As a result, simple and inexpensive substances have been replaced by complex, long chain polymers, multi component resins or plastics. For economic and ecological reasons waste materials are more frequently used as additives, admixtures and modifiers. Nowadays the most commonly used physical modifiers of bitumen belong to the group of polymers - large molecular organic compounds of natural origin or being the result of planned chemical synthesis. Polymers are substances that do not chemically react with bitumen, they act as fillers or create a spatial network within bitumen (the so called physical cross-linking). The development of organic chemistry has allowed the synthesis of a number of substances chemically modifying bitumen. The most promising are heterocyclic organic compounds belonging to the group of imidazolines. The aim of the study presented in this paper was to demonstrate the suitability of processed natural and post-refining fat waste (diamidoamine dehydrate) as bitumen modifier. This paper discusses the impact of adding technical imidazoline on selected bitumen characteristics. Samples of bitumen 160/220, which is most commonly used for the production of waterproofing products, were analysed. For base bitumen and bitumen modified with technical imidazoline the following measurements were taken: measurement of the softening point by Ball and Ring method, determination of the breaking point by Fraass method and needle penetration measurement at 25°C. Later the samples were aged using TFOT laboratory method and the basic characteristics were determined again. The results showed that a small amount of imidazoline improved bitumen thermoplastic parameters at low temperatures and had a significant impact on weakening bitumen oxidation and ageing. The addition of technical imidazoline prevents bitumen from hardening, thus increasing its flexibility and its resistance to mechanical damage. Due to many difficulties in the production of polymer bitumens and in order to find cheaper, more environment friendly solutions, the authors proposed an ecological bituminous modifier which, due to chemical reaction with binders, creates a stable and firm in time product. Imidazolines have a negative impact on bitumen softening point, which makes them impossible to use as an independent modifier. Therefore, at a later stage of the research, the authors will attempt to create a hybrid bitumen modifier which will combine the beneficial effect of polymers and imidazoline on the characteristics of bituminous binders.
Pyr Dit Ruys, S; Bonzom, J-M; Frelon, S
2016-10-01
Oxidative stress has been extensively studied due to its correlation with cellular disorders and aging. In proteins, one biomarker of oxidative stress is the presence of carbonyl groups, such as aldehyde and ketone, in specific amino acid side chains such as lysine, proline, arginine and threonine, so-called protein carbonylation (PC). PC study is now a growing field in general and medical science since PC accumulation is associated with various pathologies and disorders. At present, enzyme-linked immunosorbent assays (ELISA) seem to be the most robust method of quantifying the presence of carbonyl groups in proteins, despite having some recognised caveats. In parallel, gel-based approaches present cross-comparison difficulties, along with other technical problems. As generic PC analyses still suffer from poor homogeneity, leading to cross-data analysis difficulties and poor results overlap, the need for harmonisation in the field of carbonyl detection is now widely accepted. This study aims to highlight some of the technical challenges in proteomic gel-based multiplexing experiments when dealing with PC in difficult samples like those from Caenorhabditis elegans, from protein extraction to carbonyl detection. We demonstrate that some critical technical parameters, such as labelling time, probe concentration, and total and carbonylated protein recovery rates, should be re-addressed in a sample-specific way. We also defined a procedure to cost-effectively adapt CyDye™-hydrazide-based protocols to specific samples, especially when the experimental interest is focused on studying differences between stimulating conditions with a maximised signal-to-noise ratio. Moreover, we have improved an already-existing powerful solubilisation buffer, making it potentially useful for hard-to-solubilise protein pellets. Lastly, the depicted methodology exemplifies a simple way of normalising carbonyl-related signal to total protein in SDS-PAGE multiplexing experiments. Within that scope, we also proposed a simple way to quantify carbonyl groups by on-gel spotting diluted dye-containing labelling buffer. Proof of the robustness of the procedure was also highlighted by the high linear correlation between the level of carbonyls and the ultraviolet exposure duration of whole worms (R 2 =0.993). Altogether, these results will help to standardise existing protocols in the growing field of proteomic carbonylation studies. Copyright © 2016 Elsevier Inc. All rights reserved.
Alexander, C J; Hammer, J A
2016-01-01
We present a simple and efficient method to knock down proteins specifically in Purkinje neurons (PN) present in mixed mouse primary cerebellar cultures. This method utilizes the introduction via nucleofection of a plasmid encoding a specific miRNA downstream of the L7/Pcp2 promoter, which drives PN-specific expression. As proof-of-principle, we used this plasmid to knock down the motor protein myosin Va, which is required for the targeting of smooth endoplasmic reticulum (ER) into PN spines. Consistent with effective knockdown, transfected PNs robustly phenocopied PNs from dilute-lethal (myosin Va-null) mice with regard to the ER targeting defect. Importantly, our plasmid-based approach is less challenging technically and more specific to PNs than several alternative methods (e.g., biolistic- and lentiviral-based introduction of siRNAs). We also present a number of improvements for generating mixed cerebellar cultures that shorten the procedure and improve the total yield of PNs, and of transfected PNs, considerably. Finally, we present a method to rescue cerebellar cultures that develop large cell aggregates, a common problem that otherwise precludes the further use of the culture. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhang, Rui; Newhauser, Wayne D.
2009-03-01
In proton therapy, the radiological thickness of a material is commonly expressed in terms of water equivalent thickness (WET) or water equivalent ratio (WER). However, the WET calculations required either iterative numerical methods or approximate methods of unknown accuracy. The objective of this study was to develop a simple deterministic formula to calculate WET values with an accuracy of 1 mm for materials commonly used in proton radiation therapy. Several alternative formulas were derived in which the energy loss was calculated based on the Bragg-Kleeman rule (BK), the Bethe-Bloch equation (BB) or an empirical version of the Bethe-Bloch equation (EBB). Alternative approaches were developed for targets that were 'radiologically thin' or 'thick'. The accuracy of these methods was assessed by comparison to values from an iterative numerical method that utilized evaluated stopping power tables. In addition, we also tested the approximate formula given in the International Atomic Energy Agency's dosimetry code of practice (Technical Report Series No 398, 2000, IAEA, Vienna) and stopping power ratio approximation. The results of these comparisons revealed that most methods were accurate for cases involving thin or low-Z targets. However, only the thick-target formulas provided accurate WET values for targets that were radiologically thick and contained high-Z material.
Ahn, Sang-Hoon; Son, Sang-Yong; Jung, Do Hyun; Park, Young Suk; Shin, Dong Joon; Park, Do Joong; Kim, Hyung-Ho
2015-06-01
Single-incision laparoscopic total gastrectomy for gastric cancer has recently been reported by Seoul National University Bundang Hospital. However, this is not a popular procedure primarily because of the technical difficulties involved in achieving consistent intracorporeal esophagojejunostomy. At Seoul National University Bundang Hospital, we recently introduced a simple, easy-to-use, low-profile laparoscopic manual scope holder that enables the maintenance of a stable field of view, the most demanding condition in single-port gastrectomy. In this technical report, we describe in detail the world's first solo single-incision laparoscopic total gastrectomy with D1+ lymph node dissection and intracorporeal esophagojejunostomy for proximal early gastric cancer.
Ahn, Sang-Hoon; Son, Sang-Yong; Jung, Do Hyun; Park, Young Suk; Shin, Dong Joon; Park, Do Joong
2015-01-01
Single-incision laparoscopic total gastrectomy for gastric cancer has recently been reported by Seoul National University Bundang Hospital. However, this is not a popular procedure primarily because of the technical difficulties involved in achieving consistent intracorporeal esophagojejunostomy. At Seoul National University Bundang Hospital, we recently introduced a simple, easy-to-use, low-profile laparoscopic manual scope holder that enables the maintenance of a stable field of view, the most demanding condition in single-port gastrectomy. In this technical report, we describe in detail the world's first solo single-incision laparoscopic total gastrectomy with D1+ lymph node dissection and intracorporeal esophagojejunostomy for proximal early gastric cancer. PMID:26161287
ERIC Educational Resources Information Center
Matveeva, Natalia
2008-01-01
This research article reports the results of an online survey distributed among technical writing instructors in 2006. The survey aimed to examine how we teach intercultural communication in basic technical writing courses: our current practices and methods. The article discusses three major challenges that instructors may face when teaching about…
University-government relationships in the training of technical writers-editors
NASA Technical Reports Server (NTRS)
Stohrer, Freda F.; Pinelli, Thomas E.
1979-01-01
Traditional and nontraditional methods of training technical writers-editors are reviewed. Combining work experience with classroom instruction in the form of cooperative education provides a method of strengthening the Federal career service in professional occupations. The NASA Langley experience that successfully introduced students to the special demands of technical writing and editing is described.
Methodology for Planning Technical Education: With a Case Study of Polytechnics in Bangladesh.
ERIC Educational Resources Information Center
Ritzen, Jozef M.; Balderston, Judith B.
A product of research first begun by one of the authors in Bangladesh, this book develops a comprehensive set of methods for planning technical education. Wherever possible, the authors draw on existing tools, fitting them to the specific context of technical education. When faced with planning problems for which existing methods are ill suited…
Assessing Technical Competence in Surgical Trainees: A Systematic Review.
Szasz, Peter; Louridas, Marisa; Harris, Kenneth A; Aggarwal, Rajesh; Grantcharov, Teodor P
2015-06-01
To systematically examine the literature describing the methods by which technical competence is assessed in surgical trainees. The last decade has witnessed an evolution away from time-based surgical education. In response, governing bodies worldwide have implemented competency-based education paradigms. The definition of competence, however, remains elusive, and the impact of these education initiatives in terms of assessment methods remains unclear. A systematic review examining the methods by which technical competence is assessed was conducted by searching MEDLINE, EMBASE, PsychINFO, and the Cochrane database of systematic reviews. Abstracts of retrieved studies were reviewed and those meeting inclusion criteria were selected for full review. Data were retrieved in a systematic manner, the validity and reliability of the assessment methods was evaluated, and quality was assessed using the Grading of Recommendations Assessment, Development and Evaluation classification. Of the 6814 studies identified, 85 studies involving 2369 surgical residents were included in this review. The methods used to assess technical competence were categorized into 5 groups; Likert scales (37), benchmarks (31), binary outcomes (11), novel tools (4), and surrogate outcomes (2). Their validity and reliability were mostly previously established. The overall Grading of Recommendations Assessment, Development and Evaluation for randomized controlled trials was high and low for the observational studies. The definition of technical competence continues to be debated within the medical literature. The methods used to evaluate technical competence predominantly include instruments that were originally created to assess technical skill. Very few studies identify standard setting approaches that differentiate competent versus noncompetent performers; subsequently, this has been identified as an area with great research potential.
The next three decades of the comet assay: a report of the 11th International Comet Assay Workshop.
Koppen, Gudrun; Azqueta, Amaya; Pourrut, Bertrand; Brunborg, Gunnar; Collins, Andrew R; Langie, Sabine A S
2017-05-01
The International Comet Assay Workshops are a series of scientific conferences dealing with practical and theoretical aspects of the Comet Assay (single-cell gel electrophoresis)-a simple method for detecting DNA strand breaks. The first paper describing such an assay was published over 30 years ago in 1984 by Swedish researchers O. Ostling and K. J. Johanson. Appropriately, the theme for the 2015 meeting was looking to the future: 'The Next 3 Decades of the Comet Assay'. The programme included 25 oral and 43 poster presentations depicting the latest advances in technical developments as well as applications of the comet assay in genotoxicity testing (in vitro and in vivo) and biomonitoring of both humans and the environment. Open discussion sessions based on questions from the participants allowed exchange of practical details on current comet assay protocols. This report summarises technical issues of high importance which were discussed during the sessions. We provide information on ways to improve the assay performance, by testing for cytotoxicity, by using reference samples to reduce or allow for inter-experimental variation, and by standardising quantification of the damage, including replicates and scoring enough comets to ensure statistical validity. After 30 years of experimentation with the comet assay, we are in a position to control the important experimental parameters and make the comet assay a truly reliable method with a wealth of possible applications. © The Author 2017. Published by Oxford University Press on behalf of the UK Environmental Mutagen Society. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Sergey Vasilievich, Buharin; Aleksandr Vladimirovich, Melnikov; Svetlana Nikolaevna, Chernyaeva; Lyudmila Anatolievna, Korobova
2017-08-01
The method of dip of the underlying computational problem of comparing technical object in an expert shell in the class of data mining methods is examined. An example of using the proposed method is given.
78 FR 5133 - Technical Corrections Regarding the Methods of Collection of Certain User Fees by CBP
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-24
...] Technical Corrections Regarding the Methods of Collection of Certain User Fees by CBP AGENCY: U.S. Customs... electronic payments through the DTOPS. While CBP's preferred method of receiving user fee prepayment requests...
Simple Test Functions in Meshless Local Petrov-Galerkin Methods
NASA Technical Reports Server (NTRS)
Raju, Ivatury S.
2016-01-01
Two meshless local Petrov-Galerkin (MLPG) methods based on two different trial functions but that use a simple linear test function were developed for beam and column problems. These methods used generalized moving least squares (GMLS) and radial basis (RB) interpolation functions as trial functions. These two methods were tested on various patch test problems. Both methods passed the patch tests successfully. Then the methods were applied to various beam vibration problems and problems involving Euler and Beck's columns. Both methods yielded accurate solutions for all problems studied. The simple linear test function offers considerable savings in computing efforts as the domain integrals involved in the weak form are avoided. The two methods based on this simple linear test function method produced accurate results for frequencies and buckling loads. Of the two methods studied, the method with radial basis trial functions is very attractive as the method is simple, accurate, and robust.
Educational Experiences of Embry-Riddle Students through NASA Research Collaboration
NASA Technical Reports Server (NTRS)
Schlee, Keith; Gangadharan, Sathya; Chatman, Yadira; Sudermann, James; Walker, Charles; Ristow, James
2006-01-01
NASA's educational. programs benefit students and faculty while increasing the overall productivity of the organization. The NASA Graduate Student Research Program (GSRP) awards fellowships for graduate study leading to both masters and doctoral degrees in several technical fields. GSRP participants have the option to utilize NASA Centers andlor university research facilities. In addition, GSRP students can serve as mentors for undergrad students to provide a truly unique learning experience. NASA's Cooperative Education Program allows undergraduate students the chance to gain "real-world" work experience in the field. It also gives NASA a no risk capability to evaluate the true performance of a prospective new hire without relying solely on a "paper resume" while providing the students with a greater hiring potential upon graduation, at NASA or elsewhere. University faculty can also benefit by participating in the NASA Faculty Fellowship Program (NFFP). This program gives the faculty an opportunity to work with NASA peers. The Mission Analysis Branch of the Expendable Launch Vehicles Division at NASA Kennedy Space Center has utilized these two programs with students from Embry-Riddle Aeronautical University (ERAU) to conduct research in modeling and developing a parameter estimation method for spacecraft fuel slosh using simple pendulum analogs. Simple pendulum models are used to understand complicated spacecraft fuel slosh behavior. A robust parameter estimation process will help to identif' the parameters that will predict the response fairly accurately during the initial stages of design. These programs provide students with a unique opportunity to work on "real-world" aerospace problems, like spacecraft fuel slosh,. This in turn reinforces their problem solving abilities and their communication skills such as interviewing, resume writing, technical writing, and presentation. Faculty benefits by applying what they have learned to the classroom. Through university collaborations with NASA and industry help students to acquire skills that are vital for their success upon entering the workforce.
Performance of technical trading rules: evidence from Southeast Asian stock markets.
Tharavanij, Piyapas; Siraprapasiri, Vasan; Rajchamaha, Kittichai
2015-01-01
This paper examines the profitability of technical trading rules in the five Southeast Asian stock markets. The data cover a period of 14 years from January 2000 to December 2013. The instruments investigated are five Southeast Asian stock market indices: SET index (Thailand), FTSE Bursa Malaysia KLC index (Malaysia), FTSE Straits Times index (Singapore), JSX Composite index (Indonesia), and PSE composite index (the Philippines). Trading strategies investigated include Relative Strength Index, Stochastic oscillator, Moving Average Convergence-Divergence, Directional Movement Indicator and On Balance Volume. Performances are compared to a simple Buy-and-Hold. Statistical tests are also performed. Our empirical results show a strong performance of technical trading rules in an emerging stock market of Thailand but not in a more mature stock market of Singapore. The technical trading rules also generate statistical significant returns in the Malaysian, Indonesian and the Philippine markets. However, after taking transaction costs into account, most technical trading rules do not generate net returns. This fact suggests different levels of market efficiency among Southeast Asian stock markets. This paper finds three new insights. Firstly, technical indicators does not help much in terms of market timing. Basically, traders cannot expect to buy at a relative low price and sell at a relative high price by just using technical trading rules. Secondly, technical trading rules can be beneficial to individual investors as they help them to counter the behavioral bias called disposition effects which is the tendency to sell winning stocks too soon and holding on to losing stocks too long. Thirdly, even profitable strategies could not reliably predict subsequent market directions. They make money from having a higher average profit from profitable trades than an average loss from unprofitable ones.
Raison, Nicholas; Ahmed, Kamran; Abe, Takashige; Brunckhorst, Oliver; Novara, Giacomo; Buffi, Nicolò; McIlhenny, Craig; van der Poel, Henk; van Hemelrijck, Mieke; Gavazzi, Andrea; Dasgupta, Prokar
2018-05-07
To investigate the effectiveness of motor imagery (MI) for technical skill and non-technical skill (NTS) training in minimally invasive surgery (MIS). A single-blind, parallel-group randomised controlled trial was conducted at the Vattikuti Institute of Robotic Surgery, King's College London. Novice surgeons were recruited by open invitation in 2015. After basic robotic skills training, participants underwent simple randomisation to either MI training or standard training. All participants completed a robotic urethrovesical anastomosis task within a simulated operating room. In addition to the technical task, participants were required to manage three scripted NTS scenarios. Assessment was performed by five blinded expert surgeons and a NTS expert using validated tools for evaluating technical skills [Global Evaluative Assessment of Robotic Skills (GEARS)] and NTS [Non-Technical Skills for Surgeons (NOTSS)]. Quality of MI was assessed using a revised Movement Imagery Questionnaire (MIQ). In all, 33 participants underwent MI training and 29 underwent standard training. Interrater reliability was high, Krippendorff's α = 0.85. After MI training, the mean (sd) GEARS score was significantly higher than after standard training, at 13.1 (3.25) vs 11.4 (2.97) (P = 0.03). There was no difference in mean NOTSS scores, at 25.8 vs 26.4 (P = 0.77). MI training was successful with significantly higher imagery scores than standard training (mean MIQ score 5.1 vs 4.5, P = 0.04). Motor imagery is an effective training tool for improving technical skill in MIS even in novice participants. No beneficial effect for NTS was found. © 2018 The Authors BJU International © 2018 BJU International Published by John Wiley & Sons Ltd.
These technical contacts are available to help with questions regarding method deviations, modifications, sample problems or interferences, quality control requirements, the use of alternative methods, or the need to address analytes or sample types.
Humor in the Classroom: Stu's Seven Simple Steps to Success
ERIC Educational Resources Information Center
Hellman, Stuart V.
2007-01-01
So you want to use humor in your classroom but think it will be inappropriate? After all, you might be thinking, you teach a very serious subject and do not want to turn your classroom into a three-ring circus. But even when teaching technical courses as systems analysis and computer programming, you can still use humor effectively in the…
UV-VIS absorption spectroscopy: Lambert-Beer reloaded
NASA Astrophysics Data System (ADS)
Mäntele, Werner; Deniz, Erhan
2017-02-01
UV-VIS absorption spectroscopy is used in almost every spectroscopy laboratory for routine analysis or research. All spectroscopists rely on the Lambert-Beer Law but many of them are less aware of its limitations. This tutorial discusses typical problems in routine spectroscopy that come along with technical limitations or careless selection of experimental parameters. Simple rules are provided to avoid these problems.
ERIC Educational Resources Information Center
Spiro, Rand J.; And Others
This report argues that there exists a pervasive tendency for analogies to contribute to the development of entrenched misconceptions in the form of reducing complex new knowledge to the core of a source analogy. The report presents a taxonomy of ways that simple analogy induces conceptual error and an alternative approach involving integrated…
ERIC Educational Resources Information Center
Gendron, Benedicte
2006-01-01
In a context of fierce competition in the labour market and employment system, the decision to continue studying after completing French short-cycle higher vocational education must be distinguished from the simple individual decision for optimum allocation of resources postulated by standard human-resource theory. It has much more to do with a…
A burr hole button to secure the electrode cable in depth electrode placement. Technical note.
Kamiryo, T; Laws, E R
1997-05-01
A simple magnetic resonance imaging-compatible buttonlike device was devised to fix a depth electrode cable securely in the burr hole used for its insertion during surgery for depth electrode placement. The button is tightly fixed in the burr hole and it holds the cable without allowing protrusion or tension on the wound.
An Easy-to-Build Remote Laboratory with Data Transfer Using the Internet School Experimental System
ERIC Educational Resources Information Center
Schauer, Frantisek; Lustig, Frantisek; Dvorak, Jiri; Ozvoldova, Miroslava
2008-01-01
The present state of information communication technology makes it possible to devise and run computer-based e-laboratories accessible to any user with a connection to the Internet, equipped with very simple technical means and making full use of web services. Thus, the way is open for a new strategy of physics education with strongly global…
ERIC Educational Resources Information Center
Suppes, Patrick; And Others
This report presents a theory of eye movement that accounts for main features of the stochastic behavior of eye-fixation durations and direction of movement of saccades in the process of solving arithmetic exercises of addition and subtraction. The best-fitting distribution of fixation durations with a relatively simple theoretical justification…
Stochastic modeling of consumer preferences for health care institutions.
Malhotra, N K
1983-01-01
This paper proposes a stochastic procedure for modeling consumer preferences via LOGIT analysis. First, a simple, non-technical exposition of the use of a stochastic approach in health care marketing is presented. Second, a study illustrating the application of the LOGIT model in assessing consumer preferences for hospitals is given. The paper concludes with several implications of the proposed approach.
Making a Fun Cartesian Diver: A Simple Project to Engage Kinaesthetic Learners
ERIC Educational Resources Information Center
Amir, Nazir; Subramaniam, R.
2007-01-01
Students in the normal technical stream are generally less academically inclined. Teaching physics to them can be a challenge. A possible way to engage such kinaesthetic learners is to encourage them to fabricate physics-based toys. The activity described in this article shows how a group of three students were able to come up with a creative…
Brown, Jocelyn; Machen, Heather; Kawaza, Kondwani; Mwanza, Zondiwe; Iniguez, Suzanne; Lang, Hans; Gest, Alfred; Kennedy, Neil; Miros, Robert; Richards-Kortum, Rebecca; Molyneux, Elizabeth; Oden, Maria
2013-01-01
Acute respiratory infections are the leading cause of global child mortality. In the developing world, nasal oxygen therapy is often the only treatment option for babies who are suffering from respiratory distress. Without the added pressure of bubble Continuous Positive Airway Pressure (bCPAP) which helps maintain alveoli open, babies struggle to breathe and can suffer serious complications, and frequently death. A stand-alone bCPAP device can cost $6,000, too expensive for most developing world hospitals. Here, we describe the design and technical evaluation of a new, rugged bCPAP system that can be made in small volume for a cost-of-goods of approximately $350. Moreover, because of its simple design—consumer-grade pumps, medical tubing, and regulators—it requires only the simple replacement of a <$1 diaphragm approximately every 2 years for maintenance. The low-cost bCPAP device delivers pressure and flow equivalent to those of a reference bCPAP system used in the developed world. We describe the initial clinical cases of a child with bronchiolitis and a neonate with respiratory distress who were treated successfully with the new bCPAP device. PMID:23372661
NASA Astrophysics Data System (ADS)
Klevtsov, S. I.
2018-05-01
The impact of physical factors, such as temperature and others, leads to a change in the parameters of the technical object. Monitoring the change of parameters is necessary to prevent a dangerous situation. The control is carried out in real time. To predict the change in the parameter, a time series is used in this paper. Forecasting allows one to determine the possibility of a dangerous change in a parameter before the moment when this change occurs. The control system in this case has more time to prevent a dangerous situation. A simple time series was chosen. In this case, the algorithm is simple. The algorithm is executed in the microprocessor module in the background. The efficiency of using the time series is affected by its characteristics, which must be adjusted. In the work, the influence of these characteristics on the error of prediction of the controlled parameter was studied. This takes into account the behavior of the parameter. The values of the forecast lag are determined. The results of the research, in the case of their use, will improve the efficiency of monitoring the technical object during its operation.
Profitability of simple technical trading rules of Chinese stock exchange indexes
NASA Astrophysics Data System (ADS)
Zhu, Hong; Jiang, Zhi-Qiang; Li, Sai-Ping; Zhou, Wei-Xing
2015-12-01
Although technical trading rules have been widely used by practitioners in financial markets, their profitability still remains controversial. We here investigate the profitability of moving average (MA) and trading range break (TRB) rules by using the Shanghai Stock Exchange Composite Index (SHCI) from May 21, 1992 through December 31, 2013 and Shenzhen Stock Exchange Component Index (SZCI) from April 3, 1991 through December 31, 2013. The t-test is adopted to check whether the mean returns which are conditioned on the trading signals are significantly different from unconditioned returns and whether the mean returns conditioned on the buy signals are significantly different from the mean returns conditioned on the sell signals. We find that TRB rules outperform MA rules and short-term variable moving average (VMA) rules outperform long-term VMA rules. By applying White's Reality Check test and accounting for the data snooping effects, we find that the best trading rule outperforms the buy-and-hold strategy when transaction costs are not taken into consideration. Once transaction costs are included, trading profits will be eliminated completely. Our analysis suggests that simple trading rules like MA and TRB cannot beat the standard buy-and-hold strategy for the Chinese stock exchange indexes.
An assessment of individualized technical ear training for audio production.
Kim, Sungyoung
2015-07-01
An individualized technical ear training method is compared to a non-individualized method. The efficacy of the individualized method is assessed using a standardized test conducted before and after the training period. Participants who received individualized training improved better than the control group on the test. Results indicate the importance of individualized training for acquisition of spectrum-identification and spectrum-matching skills. Individualized training, therefore, should be implemented by default into technical ear training programs used in audio production industry and education.
Morell, Montse; Espargaro, Alba; Aviles, Francesc Xavier; Ventura, Salvador
2008-01-01
We present a high-throughput approach to study weak protein-protein interactions by coupling bimolecular fluorescent complementation (BiFC) to flow cytometry (FC). In BiFC, the interaction partners (bait and prey) are fused to two rationally designed fragments of a fluorescent protein, which recovers its function upon the binding of the interacting proteins. For weak protein-protein interactions, the detected fluorescence is proportional to the interaction strength, thereby allowing in vivo discrimination between closely related binders with different affinity for the bait protein. FC provides a method for high-speed multiparametric data acquisition and analysis; the assay is simple, thousands of cells can be analyzed in seconds and, if required, selected using fluorescence-activated cell sorting (FACS). The combination of both methods (BiFC-FC) provides a technically straightforward, fast and highly sensitive method to validate weak protein interactions and to screen and identify optimal ligands in biologically synthesized libraries. Once plasmids encoding the protein fusions have been obtained, the evaluation of a specific interaction, the generation of a library and selection of active partners using BiFC-FC can be accomplished in 5 weeks.
Rapid Bedside Inactivation of Ebola Virus for Safe Nucleic Acid Tests.
Rosenstierne, Maiken Worsøe; Karlberg, Helen; Bragstad, Karoline; Lindegren, Gunnel; Stoltz, Malin Lundahl; Salata, Cristiano; Kran, Anne-Marte Bakken; Dudman, Susanne Gjeruldsen; Mirazimi, Ali; Fomsgaard, Anders
2016-10-01
Rapid bedside inactivation of Ebola virus would be a solution for the safety of medical and technical staff, risk containment, sample transport, and high-throughput or rapid diagnostic testing during an outbreak. We show that the commercially available Magna Pure lysis/binding buffer used for nucleic acid extraction inactivates Ebola virus. A rapid bedside inactivation method for nucleic acid tests is obtained by simply adding Magna Pure lysis/binding buffer directly into vacuum blood collection EDTA tubes using a thin needle and syringe prior to sampling. The ready-to-use inactivation vacuum tubes are stable for more than 4 months, and Ebola virus RNA is preserved in the Magna Pure lysis/binding buffer for at least 5 weeks independent of the storage temperature. We also show that Ebola virus RNA can be manually extracted from Magna Pure lysis/binding buffer-inactivated samples using the QIAamp viral RNA minikit. We present an easy and convenient method for bedside inactivation using available blood collection vacuum tubes and reagents. We propose to use this simple method for fast, safe, and easy bedside inactivation of Ebola virus for safe transport and routine nucleic acid detection. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Brezar, Vedran; Ruffin, Nicolas; Lévy, Yves; Seddiki, Nabila
2014-09-01
Regulatory T cells (Tregs) are pivotal in preventing autoimmunity. They play a major but still ambiguous role in cancer and viral infections. Functional studies of human Tregs are often hampered by numerous technical difficulties arising from imperfections in isolating and depleting protocols, together with the usual low cell number available from clinical samples. We standardized a simple procedure (Single Step Method, SSM), based on magnetic beads technology, in which both depletion and isolation of human Tregs with high purities are simultaneously achieved. SSM is suitable when using low cell numbers either fresh or frozen from both patients and healthy individuals. It allows simultaneous Tregs isolation and depletion that can be used for further functional work to monitor suppressive function of isolated Tregs (in vitro suppression assay) and also effector IFN-γ responses of Tregs-depleted cell fraction (OX40 assay). To our knowledge, there is no accurate standardized method for Tregs isolation and depletion in a clinical context. SSM could thus be used and easily standardized across different laboratories. Copyright © 2014 Elsevier B.V. All rights reserved.
Yeung, Joyce H Y; Ong, G J; Davies, Robin P; Gao, Fang; Perkins, Gavin D
2012-09-01
This study aims to explore the relationship between team-leadership skills and quality of cardiopulmonary resuscitation in an adult cardiac-arrest simulation. Factors affecting team-leadership skills were also assessed. Forty advanced life-support providers leading a cardiac arrest team in a standardized cardiac-arrest simulation were videotaped. Background data were collected, including age (in yrs), sex, whether they had received any leadership training in the past, whether they were part of a professional group, the most recent advanced life-support course (in months) they had undergone, advanced life-support instructor/provider status, and whether they had led in any cardiac arrest situation in the preceding 6 months. Participants were scored using the Cardiac Arrest Simulation test score and Leadership Behavior Description Questionnaire for leadership skills. Process-focused quality of cardiopulmonary resuscitation data were collected directly from manikin and video recordings. Primary outcomes were complex technical skills (measured as Cardiac Arrest Simulation test score, preshock pause, and hands-off ratio). Secondary outcomes were simple technical skills (chest-compression rate, depth, and ventilation rate). Univariate linear regressions were performed to examine how leadership skills affect quality of cardiopulmonary resuscitation and bivariate correlations elicited factors affecting team-leadership skills.Teams led by leaders with the best leadership skills performed higher quality cardiopulmonary resuscitation with better technical performance (R = 0.75, p < .001), shorter preshock pauses (R = 0.18, p < .001), with lower total hands-off ratio (R = 0.24, p = .01), and shorter time to first shock (R = 0.14, p = .02). Leadership skills were not significantly associated with more simple technical skills such as chest-compression rate, depth, and ventilation rate. Prior training in team leader skills was independently associated with better leadership behavior. There is an association between team leadership skills and cardiac arrest simulation test score, preshock pause, and hands off ratio. Developing leadership skills should be considered an integral part of resuscitation training.
Leetz, H-K; Eipper, H H; Gfirtner, H; Schneider, P; Welker, K
2014-08-01
In 1994 and 1998 reports on staffing levels in medical radiation physics for radiation therapy were published by the "Deutsche Gesellschaft für Medizinische Physik" (DGMP, German Society for Medical Physics). Because of the technical and methodological progress, changes in recommended qualifications of staff and new governmental regulations, it was necessary to establish new staffing levels. The data were derived from a new survey in clinics. Some of the previously established results from the old reports were adapted to the new conditions by conversion.The staffing requirements were normalized to main components as in the earlier reports resulting in a simple method for calculation of staffing levels. The results were compared with the requirements in the "Richtlinie Strahlenschutz in der Medizin" (guidelines on radiation protection in medicine) and showed satisfactory agreement.
Monitoring of aflatoxins and ochratoxin A in Czechoslovak human sera by immunoassay
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fukal, L.; Reisnerova, H.
1990-03-01
Since a level of food contamination with aflatoxins and ochratoxin A has been found low in Czechoslovakia, human exposure to these mycotoxins may not be negligible. However, analysis of food samples provides only indirect evidence of mycotoxin ingestion and no evidence about mycotoxin absorption. Direct evidence can only be obtained by analysis of human body fluids. Therefore, the authors decided to carry out a monitoring of aflatoxin and ochratoxin A level in human sera. In general, TLC and HPLC are most commonly used to analyze mycotoxins and its metabolites. The recent development of immunochemical techniques opens the possibility of determiningmore » individual exposure in a relatively large human population. These assays have the advantage of high specificity and sensitivity. Sample through-put is high, and the methods are technically simple and can be performed at low cost.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Palmintier, Bryan S; Bugbee, Bruce; Gotseff, Peter
Capturing technical and economic impacts of solar photovoltaics (PV) and other distributed energy resources (DERs) on electric distribution systems can require high-time resolution (e.g. 1 minute), long-duration (e.g. 1 year) simulations. However, such simulations can be computationally prohibitive, particularly when including complex control schemes in quasi-steady-state time series (QSTS) simulation. Various approaches have been used in the literature to down select representative time segments (e.g. days), but typically these are best suited for lower time resolutions or consider only a single data stream (e.g. PV production) for selection. We present a statistical approach that combines stratified sampling and bootstrapping tomore » select representative days while also providing a simple method to reassemble annual results. We describe the approach in the context of a recent study with a utility partner. This approach enables much faster QSTS analysis by simulating only a subset of days, while maintaining accurate annual estimates.« less
Biomimetic membrane arrays on cast hydrogel supports.
Roerdink Lander, Monique; Ibragimova, Sania; Rein, Christian; Vogel, Jörg; Stibius, Karin; Geschke, Oliver; Perry, Mark; Hélix-Nielsen, Claus
2011-06-07
Lipid bilayers are intrinsically fragile and require mechanical support in technical applications based on biomimetic membranes. Tethering the lipid bilayer membranes to solid substrates, either directly through covalent or ionic substrate-lipid links or indirectly on substrate-supported cushions, provides mechanical support but at the cost of small molecule transport through the membrane-support sandwich. To stabilize biomimetic membranes while allowing transport through a membrane-support sandwich, we have investigated the feasibility of using an ethylene tetrafluoroethylene (ETFE)/hydrogel sandwich as the support. The sandwich is realized as a perforated surface-treated ETFE film onto which a hydrogel composite support structure is cast. We report a simple method to prepare arrays of lipid bilayer membranes with low intrinsic electrical conductance on the highly permeable, self-supporting ETFE/hydrogel sandwiches. We demonstrate how the ETFE/hydrogel sandwich support promotes rapid self-thinning of lipid bilayers suitable for hosting membrane-spanning proteins.
Zachariah, Sanoop K.
2010-01-01
The introduction of circular end-to-end stapling devices (CEEA OR EEA stapler) into colorectal surgery have revolutionised anastomotic techniques. The EEA stapler is generally regarded as an instrument that is safe, reliable, and simple to operate. Despite it’s popularity, very little information is available regarding the technical difficulties encountered during surgery. The routine technique to perform an end-to-end circular colonic anastomosis is to introduce the instrument distally through the anus (transrectal/transanal approach) and attach it to the anvil which is purse stringed at the distal end of the proximal bowel to be anastomosed. Two cases of reversal of Hartmann’s procedure for perforated diverticulitis are described in the present study, where difficulty was experienced while using the EEA stapler in the routine method. Hence, an alternative reverse technique which was used is presented. PMID:22091338
A global standard for monitoring coastal wetland vulnerability to accelerated sea-level rise
Webb, Edward L.; Friess, Daniel A.; Krauss, Ken W.; Cahoon, Donald R.; Guntenspergen, Glenn R.; Phelps, Jacob
2013-01-01
Sea-level rise threatens coastal salt-marshes and mangrove forests around the world, and a key determinant of coastal wetland vulnerability is whether its surface elevation can keep pace with rising sea level. Globally, a large data gap exists because wetland surface and shallow subsurface processes remain unaccounted for by traditional vulnerability assessments using tide gauges. Moreover, those processes vary substantially across wetlands, so modelling platforms require relevant local data. The low-cost, simple, high-precision rod surface-elevation table–marker horizon (RSET-MH) method fills this critical data gap, can be paired with spatial data sets and modelling and is financially and technically accessible to every country with coastal wetlands. Yet, RSET deployment has been limited to a few regions and purposes. A coordinated expansion of monitoring efforts, including development of regional networks that could support data sharing and collaboration, is crucial to adequately inform coastal climate change adaptation policy at several scales.
Taming the nonlinearity of the Einstein equation.
Harte, Abraham I
2014-12-31
Many of the technical complications associated with the general theory of relativity ultimately stem from the nonlinearity of Einstein's equation. It is shown here that an appropriate choice of dynamical variables may be used to eliminate all such nonlinearities beyond a particular order: Both Landau-Lifshitz and tetrad formulations of Einstein's equation are obtained that involve only finite products of the unknowns and their derivatives. Considerable additional simplifications arise in physically interesting cases where metrics become approximately Kerr or, e.g., plane waves, suggesting that the variables described here can be used to efficiently reformulate perturbation theory in a variety of contexts. In all cases, these variables are shown to have simple geometrical interpretations that directly relate the local causal structure associated with the metric of interest to the causal structure associated with a prescribed background. A new method to search for exact solutions is outlined as well.
Baldwin, D.E.; Logan, B.G.
The invention provides a method and apparatus for raising the potential of a magnetic mirror cell by pumping charged particles of the opposite sign of the potential desired out of the mirror cell through excitation, with the pumping being done by an externally imposed field at the bounce frequence of the above charged particles. These pumped simple mirror cells then provide end stoppering for a center mirror cell for the tandem mirror plasma confinement apparatus. For the substantially complete pumping case, the end plugs of a tandem mirror can be up to two orders of magnitude lower in density for confining a given center mirror cell plasma than in the case of end plugs without pumping. As a result the decrease in recirculating power required to keep the system going, the technical state of the art required, and the capital cost are all greatly lowered.
El-Sayed, Mohamed; Atef, Ashraf
2012-10-01
Although intramedullary fixation of closed simple (type A or B) diaphyseal tibial fractures in adults is well tolerated by patients, providing lower morbidity rates and better mobility, it is associated with some complications. This study evaluated the results of managing these fractures using percutaneous minimal internal fixation using one or more lag screws, and Ilizarov external fixation. This method was tested to evaluate its efficacy in immediate weight bearing, fracture healing and prevention of any post-immobilisation stiffness of the ankle and knee joints. This randomised blinded study was performed at a referral, academically supervised, level III trauma centre. Three hundred and twenty-four of the initial 351 patients completed this study and were followed up for a minimum of 12 (12-88) months. Patient ages ranged from 20 to 51 years, with a mean of 39 years. Ankle and knee movements and full weight bearing were encouraged immediately postoperatively. Solid union was assessed clinically and radiographically. Active and passive ankle and knee ranges of motion were measured and compared with the normal side using the Wilcoxon signed rank test for matched pairs. Subjective Olerud and Molander Ankle Score was used to detect any ankle joint symptoms at the final follow-up. No patient showed delayed or nonunion. All fractures healed within 95-129 days. Based on final clinical and radiographic outcomes, this technique proves to be adequate for managing simple diaphyseal tibial fractures. On the other hand, it is relatively expensive, technically demanding, necessitates exposure to radiation and patients are expected to be frame friendly.
NASA Astrophysics Data System (ADS)
Glinka, Kevin; Matthies, Michael; Theiling, Marius; Hideg, Kalman; Steinhoff, Heinz-Jürgen
2016-04-01
Sulfonamide antibiotics used in livestock farming are distributed to farmland by application of slurry as fertilizer. Previous work suggests rapid covalent binding of the aniline moiety to humic acids found in soil. In the current work, kinetics of this binding were measured in X-band EPR spectroscopy by incubating Leonardite humic acid (LHA) with a paramagnetic aniline spin label (anilino-NO (2,5,5-Trimethyl-2-(3-aminophenyl)pyrrolidin-1-oxyl)). Binding was detected by a pronounced broadening of the spectral lines after incubation of LHA with anilino-NO. The time evolution of the amplitude of this feature was used for determining the reaction kinetics. Single- and double-exponential models were fitted to the data obtained for modelling one or two first-order reactions. Reaction rates of 0.16 min-1 and 0.012 min-1, were found respectively. Addition of laccase peroxidase did not change the kinetics but significantly enhanced the reacting fraction of anilino-NO. This EPR-based method provides a technically simple and effective method for following rapid binding processes of a xenobiotic substance to humic acids.
Feller processes: the next generation in modeling. Brownian motion, Lévy processes and beyond.
Böttcher, Björn
2010-12-03
We present a simple construction method for Feller processes and a framework for the generation of sample paths of Feller processes. The construction is based on state space dependent mixing of Lévy processes. Brownian Motion is one of the most frequently used continuous time Markov processes in applications. In recent years also Lévy processes, of which Brownian Motion is a special case, have become increasingly popular. Lévy processes are spatially homogeneous, but empirical data often suggest the use of spatially inhomogeneous processes. Thus it seems necessary to go to the next level of generalization: Feller processes. These include Lévy processes and in particular brownian motion as special cases but allow spatial inhomogeneities. Many properties of Feller processes are known, but proving the very existence is, in general, very technical. Moreover, an applicable framework for the generation of sample paths of a Feller process was missing. We explain, with practitioners in mind, how to overcome both of these obstacles. In particular our simulation technique allows to apply Monte Carlo methods to Feller processes.
Feller Processes: The Next Generation in Modeling. Brownian Motion, Lévy Processes and Beyond
Böttcher, Björn
2010-01-01
We present a simple construction method for Feller processes and a framework for the generation of sample paths of Feller processes. The construction is based on state space dependent mixing of Lévy processes. Brownian Motion is one of the most frequently used continuous time Markov processes in applications. In recent years also Lévy processes, of which Brownian Motion is a special case, have become increasingly popular. Lévy processes are spatially homogeneous, but empirical data often suggest the use of spatially inhomogeneous processes. Thus it seems necessary to go to the next level of generalization: Feller processes. These include Lévy processes and in particular Brownian motion as special cases but allow spatial inhomogeneities. Many properties of Feller processes are known, but proving the very existence is, in general, very technical. Moreover, an applicable framework for the generation of sample paths of a Feller process was missing. We explain, with practitioners in mind, how to overcome both of these obstacles. In particular our simulation technique allows to apply Monte Carlo methods to Feller processes. PMID:21151931
Introduction to the thermodynamic Bethe ansatz
NASA Astrophysics Data System (ADS)
van Tongeren, Stijn J.
2016-08-01
We give a pedagogical introduction to the thermodynamic Bethe ansatz, a method that allows us to describe the thermodynamics of integrable models whose spectrum is found via the (asymptotic) Bethe ansatz. We set the stage by deriving the Fermi-Dirac distribution and associated free energy of free electrons, and then in a similar though technically more complicated fashion treat the thermodynamics of integrable models, focusing first on the one-dimensional Bose gas with delta function interaction as a clean pedagogical example, secondly the XXX spin chain as an elementary (lattice) model with prototypical complicating features in the form of bound states, and finally the {SU}(2) chiral Gross-Neveu model as a field theory example. Throughout this discussion we emphasize the central role of particle and hole densities, whose relations determine the model under consideration. We then discuss tricks that allow us to use the same methods to describe the exact spectra of integrable field theories on a circle, in particular the chiral Gross-Neveu model. We moreover discuss the simplification of TBA equations to Y systems, including the transition back to integral equations given sufficient analyticity data, in simple examples.
Georgeson, David L; Christiansen, Byron H
2018-06-01
Idaho National Laboratory transitioned from an external dosimetry system reliant on thermoluminescent dosimeters to one that uses optically stimulated luminescence dosimeters in 2010. This change not only affected the dosimeters worn by personnel, but those found in the nuclear-accident dosimeters used across Idaho National Laboratory. The elimination of on-site use and processing of thermoluminescent dosimeters impacted Idaho National Laboratory's ability to process nuclear-accident dosimeters in a timely manner. This change in processes drove Idaho National Laboratory to develop an alternative method for fixed nuclear-accident dosimeter gamma-dose analyses. This new method was driven by the need to establish a simple, cost-effective, and rapid-turnaround alternative to the thermoluminescent-dosimeter-based fixed nuclear-accident dosimeter system. An adaptation of existing technologies proved to be the most efficient path to this end. The purpose of this article is to delineate the technical basis for replacing the thermoluminescent dosimeter contained within the Idaho National Laboratory fixed nuclear-accident dosimeter system with optically stimulated luminescence-based Landauer, Inc., nanoDot dosimeters.
NASA Astrophysics Data System (ADS)
Zhang, Qiankun; Liu, Yinan; Lai, Jiawei; Qi, Shaomian; An, Chunhua; Lu, Yao; Duan, Xuexin; Pang, Wei; Zhang, Daihua; Sun, Dong; Chen, Jian-Hao; Liu, Jing
2018-04-01
Few-layer black phosphorus (FLBP), a recently discovered two-dimensional semiconductor, has attracted substantial attention in the scientific and technical communities due to its great potential in electronic and optoelectronic applications. However, reactivity of FLBP flakes with ambient species limits its direct applications. Among various methods to passivate FLBP in ambient environment, nanocomposites mixing FLBP flakes with stable matrix may be one of the most promising approaches for industry applications. Here, we report a simple one-step procedure to mass produce air-stable FLBP/phospholipids nanocomposite in liquid phase. The resultant nanocomposite is found to have ultralow tunneling barrier for charge carriers which can be described by an Efros-Shklovskii variable range hopping mechanism. Devices made from such mass-produced FLBP/phospholipids nanocomposite show highly stable electrical conductivity and opto-electrical response in ambient conditions, indicating its promising applications in both electronic and optoelectronic applications. This method could also be generalized to the mass production of nanocomposites consisting of other air-sensitive 2D materials, such as FeSe, NbSe2, WTe2, etc.
Pond, K R; Holladay, S D; Luginbuhl, J M
1992-04-01
Two methods to preserve gastrointestinal tract (GIT) organs and tissues, plastic coating (PC) and plastination (PN), were investigated and compared. Specimens to be preserved were removed from animals within 2 h of death and immediately cleaned with water. Digesta contents were removed by flushing desired portions of GIT with water until the exiting water was clear. In the PC method, cleaned specimens were dehydrated by immersion in an isopropanol solution, dried with forced air after positioning and orientation as in situ, and finally coated on the outer and inner surfaces with a clear plastic material. In the PN procedure, specimens were filled with, and submerged in, a low-formaldehyde fixative, then dehydrated by immersion in a cold acetone solution. Dehydrated specimens were immersed in silicone and placed in a freeze drier for impregnation under low vacuum, followed by overnight gas curing with a silicone crosslinker. Finally, viewing windows were cut out with a scalpel in GIT preserved by both methods. Preserved GIT and tissues had an appearance similar to their appearance in vivo. The PC method was simple and inexpensive. Plastinated specimens were more flexible, durable, and lifelike than those preserved by the PC method. In addition, many body parts, such as muscles, nerves, bones, ligaments, and central nervous system specimens, were preserved by PN. Both methods were found to be useful tools for postmortem studies of tissues and GIT organs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-09-01
This document presents a modeling and control study of the Fluid Bed Gasification (FBG) unit at the Morgantown Energy Technology Center (METC). The work is performed under contract no. DE-FG21-94MC31384. The purpose of this study is to generate a simple FBG model from process data, and then use the model to suggest an improved control scheme which will improve operation of the gasifier. The work first developes a simple linear model of the gasifier, then suggests an improved gasifier pressure and MGCR control configuration, and finally suggests the use of a multivariable control strategy for the gasifier.
Igarashi, Takehito; Shimizu, Kazuo; Yakubouski, Siarhei; Akasu, Haruki; Okamura, Ritsuko; Sugitani, Iwao; Jikuzono, Tomoo; Danilova, Larisa
2013-11-01
We developed video-assisted neck surgery (VANS) - a feasible, simple, and safe endoscopic thyroid procedure with cosmetic benefits - in 1998. To date, we have performed this procedure 633 times. We have also introduced the VANS method in Belarus, a country that was left contaminated by the Chernobyl nuclear disaster. From a mass screening, nine Belarusian patients, including two with papillary carcinoma of the thyroid, were selected to undergo an operation using the VANS method, performed by a single surgeon (author Shimizu). We compared indicating factors for minimally invasive surgery, specifically the operating time and blood loss, between the Belarusian cases and the 33 most recent cases performed at our institute in Tokyo. The procedures in Belarus were performed under very different working conditions than in Japan. However, operating time and blood loss improved for the Belarusian cases as the surgeon gained experience in this environment; all the cosmetic outcomes were excellent. Subsequently, over a 2-year period, surgeons in Belarus performed the VANS method, with modification, for 29 cases of thyroid tumor. The VANS method is easily learned by inexperienced surgeons without major technical problems. © 2013 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.
NASA Astrophysics Data System (ADS)
Li, Q.; Wang, Y. L.; Li, H. C.; Zhang, M.; Li, C. Z.; Chen, X.
2017-12-01
Rainfall threshold plays an important role in flash flood warning. A simple and easy method, using Rational Equation to calculate rainfall threshold, was proposed in this study. The critical rainfall equation was deduced from the Rational Equation. On the basis of the Manning equation and the results of Chinese Flash Flood Survey and Evaluation (CFFSE) Project, the critical flow was obtained, and the net rainfall was calculated. Three aspects of the rainfall losses, i.e. depression storage, vegetation interception, and soil infiltration were considered. The critical rainfall was the sum of the net rainfall and the rainfall losses. Rainfall threshold was estimated after considering the watershed soil moisture using the critical rainfall. In order to demonstrate this method, Zuojiao watershed in Yunnan Province was chosen as study area. The results showed the rainfall thresholds calculated by the Rational Equation method were approximated to the rainfall thresholds obtained from CFFSE, and were in accordance with the observed rainfall during flash flood events. Thus the calculated results are reasonable and the method is effective. This study provided a quick and convenient way to calculated rainfall threshold of flash flood warning for the grass root staffs and offered technical support for estimating rainfall threshold.
Technical Note: Approximate Bayesian parameterization of a process-based tropical forest model
NASA Astrophysics Data System (ADS)
Hartig, F.; Dislich, C.; Wiegand, T.; Huth, A.
2014-02-01
Inverse parameter estimation of process-based models is a long-standing problem in many scientific disciplines. A key question for inverse parameter estimation is how to define the metric that quantifies how well model predictions fit to the data. This metric can be expressed by general cost or objective functions, but statistical inversion methods require a particular metric, the probability of observing the data given the model parameters, known as the likelihood. For technical and computational reasons, likelihoods for process-based stochastic models are usually based on general assumptions about variability in the observed data, and not on the stochasticity generated by the model. Only in recent years have new methods become available that allow the generation of likelihoods directly from stochastic simulations. Previous applications of these approximate Bayesian methods have concentrated on relatively simple models. Here, we report on the application of a simulation-based likelihood approximation for FORMIND, a parameter-rich individual-based model of tropical forest dynamics. We show that approximate Bayesian inference, based on a parametric likelihood approximation placed in a conventional Markov chain Monte Carlo (MCMC) sampler, performs well in retrieving known parameter values from virtual inventory data generated by the forest model. We analyze the results of the parameter estimation, examine its sensitivity to the choice and aggregation of model outputs and observed data (summary statistics), and demonstrate the application of this method by fitting the FORMIND model to field data from an Ecuadorian tropical forest. Finally, we discuss how this approach differs from approximate Bayesian computation (ABC), another method commonly used to generate simulation-based likelihood approximations. Our results demonstrate that simulation-based inference, which offers considerable conceptual advantages over more traditional methods for inverse parameter estimation, can be successfully applied to process-based models of high complexity. The methodology is particularly suitable for heterogeneous and complex data structures and can easily be adjusted to other model types, including most stochastic population and individual-based models. Our study therefore provides a blueprint for a fairly general approach to parameter estimation of stochastic process-based models.
Planning a DSN support section technical library
NASA Technical Reports Server (NTRS)
Bailey, T.; Chatburn, C. C.
1980-01-01
The planning procedure being used to establish a technical library for the Deep Space Network support section is described. The inventory and survey methods employed are described and the preliminary results of these methods are discussed.
Training and Maintaining System-Wide Reliability in Outcome Management.
Barwick, Melanie A; Urajnik, Diana J; Moore, Julia E
2014-01-01
The Child and Adolescent Functional Assessment Scale (CAFAS) is widely used for outcome management, for providing real time client and program level data, and the monitoring of evidence-based practices. Methods of reliability training and the assessment of rater drift are critical for service decision-making within organizations and systems of care. We assessed two approaches for CAFAS training: external technical assistance and internal technical assistance. To this end, we sampled 315 practitioners trained by external technical assistance approach from 2,344 Ontario practitioners who had achieved reliability on the CAFAS. To assess the internal technical assistance approach as a reliable alternative training method, 140 practitioners trained internally were selected from the same pool of certified raters. Reliabilities were high for both practitioners trained by external technical assistance and internal technical assistance approaches (.909-.995, .915-.997, respectively). 1 and 3-year estimates showed some drift on several scales. High and consistent reliabilities over time and training method has implications for CAFAS training of behavioral health care practitioners, and the maintenance of CAFAS as a global outcome management tool in systems of care.
Reuleaux models at St. Petersburg State University
NASA Astrophysics Data System (ADS)
Kuteeva, G. A.; Sinilshchikova, G. A.; Trifonenko, B. V.
2018-05-01
Franz Reuleaux (1829 - 1905) is a famous mechanical engineer, a Professor of the Berlin Royal Technical Academy. He became widely known as an engineer-scientist, a Professor and industrial consultant, education reformer and leader of the technical elite of Germany. He directed the design and manufacture of over 300 models of simple mechanisms. They were sold to many famous universities for pedagogical and scientific purposes. Today, the most complete set is at Cornell University, College of Engineering. In this article we discuss the history, the modern state and our using the Reuleaux models that survived at St. Petersburg State University for educational purposes. We present description of certain models and our electronic resource with these models. We provide the information of similar electronic resources from other universities.
Optogenetic Activation of Zebrafish Somatosensory Neurons using ChEF-tdTomato
Palanca, Ana Marie S.; Sagasti, Alvaro
2013-01-01
Larval zebrafish are emerging as a model for describing the development and function of simple neural circuits. Due to their external fertilization, rapid development, and translucency, zebrafish are particularly well suited for optogenetic approaches to investigate neural circuit function. In this approach, light-sensitive ion channels are expressed in specific neurons, enabling the experimenter to activate or inhibit them at will and thus assess their contribution to specific behaviors. Applying these methods in larval zebrafish is conceptually simple but requires the optimization of technical details. Here we demonstrate a procedure for expressing a channelrhodopsin variant in larval zebrafish somatosensory neurons, photo-activating single cells, and recording the resulting behaviors. By introducing a few modifications to previously established methods, this approach could be used to elicit behavioral responses from single neurons activated up to at least 4 days post-fertilization (dpf). Specifically, we created a transgene using a somatosensory neuron enhancer, CREST3, to drive the expression of the tagged channelrhodopsin variant, ChEF-tdTomato. Injecting this transgene into 1-cell stage embryos results in mosaic expression in somatosensory neurons, which can be imaged with confocal microscopy. Illuminating identified cells in these animals with light from a 473 nm DPSS laser, guided through a fiber optic cable, elicits behaviors that can be recorded with a high-speed video camera and analyzed quantitatively. This technique could be adapted to study behaviors elicited by activating any zebrafish neuron. Combining this approach with genetic or pharmacological perturbations will be a powerful way to investigate circuit formation and function. PMID:23407374
In vivo Assembly in Escherichia coli of Transformation Vectors for Plastid Genome Engineering
Wu, Yuyong; You, Lili; Li, Shengchun; Ma, Meiqi; Wu, Mengting; Ma, Lixin; Bock, Ralph; Chang, Ling; Zhang, Jiang
2017-01-01
Plastid transformation for the expression of recombinant proteins and entire metabolic pathways has become a promising tool for plant biotechnology. However, large-scale application of this technology has been hindered by some technical bottlenecks, including lack of routine transformation protocols for agronomically important crop plants like rice or maize. Currently, there are no standard or commercial plastid transformation vectors available for the scientific community. Construction of a plastid transformation vector usually requires tedious and time-consuming cloning steps. In this study, we describe the adoption of an in vivo Escherichia coli cloning (iVEC) technology to quickly assemble a plastid transformation vector. The method enables simple and seamless build-up of a complete plastid transformation vector from five DNA fragments in a single step. The vector assembled for demonstration purposes contains an enhanced green fluorescent protein (GFP) expression cassette, in which the gfp transgene is driven by the tobacco plastid ribosomal RNA operon promoter fused to the 5′ untranslated region (UTR) from gene10 of bacteriophage T7 and the transcript-stabilizing 3′UTR from the E. coli ribosomal RNA operon rrnB. Successful transformation of the tobacco plastid genome was verified by Southern blot analysis and seed assays. High-level expression of the GFP reporter in the transplastomic plants was visualized by confocal microscopy and Coomassie staining, and GFP accumulation was ~9% of the total soluble protein. The iVEC method represents a simple and efficient approach for construction of plastid transformation vector, and offers great potential for the assembly of increasingly complex vectors for synthetic biology applications in plastids. PMID:28871270
In vivo Assembly in Escherichia coli of Transformation Vectors for Plastid Genome Engineering.
Wu, Yuyong; You, Lili; Li, Shengchun; Ma, Meiqi; Wu, Mengting; Ma, Lixin; Bock, Ralph; Chang, Ling; Zhang, Jiang
2017-01-01
Plastid transformation for the expression of recombinant proteins and entire metabolic pathways has become a promising tool for plant biotechnology. However, large-scale application of this technology has been hindered by some technical bottlenecks, including lack of routine transformation protocols for agronomically important crop plants like rice or maize. Currently, there are no standard or commercial plastid transformation vectors available for the scientific community. Construction of a plastid transformation vector usually requires tedious and time-consuming cloning steps. In this study, we describe the adoption of an in vivo Escherichia coli cloning (iVEC) technology to quickly assemble a plastid transformation vector. The method enables simple and seamless build-up of a complete plastid transformation vector from five DNA fragments in a single step. The vector assembled for demonstration purposes contains an enhanced green fluorescent protein (GFP) expression cassette, in which the gfp transgene is driven by the tobacco plastid ribosomal RNA operon promoter fused to the 5' untranslated region (UTR) from gene10 of bacteriophage T7 and the transcript-stabilizing 3'UTR from the E. coli ribosomal RNA operon rrnB . Successful transformation of the tobacco plastid genome was verified by Southern blot analysis and seed assays. High-level expression of the GFP reporter in the transplastomic plants was visualized by confocal microscopy and Coomassie staining, and GFP accumulation was ~9% of the total soluble protein. The iVEC method represents a simple and efficient approach for construction of plastid transformation vector, and offers great potential for the assembly of increasingly complex vectors for synthetic biology applications in plastids.
Caskey, Robert C; Owei, Lily; Rao, Raghavendra; Riddle, Elijah W; Brooks, Ari D; Dempsey, Daniel T; Morris, Jon B; Neylan, Christopher J; Williams, Noel N; Dumon, Kristoffel R
Nontechnical skills are an essential component of surgical education and a major competency assessed by the ACGME milestones project. However, the optimal way to integrate nontechnical skills training into existing curricula and then objectively evaluate the outcome is still unknown. The aim of this study was to determine the effect laparoscopic team-based task training would have on the nontechnical skills needed for laparoscopic surgery. 9 PGY-1 residents underwent an established training curriculum for teaching the knowledge and technical skills involved in laparoscopic cholecystectomy. Initial training involved a didactic session, expert-led practice on a porcine model in a simulated operating room and laparoscopic skills practice on a virtual reality trainer. Residents then performed a laparoscopic cholecystectomy on the same porcine model as a preintervention test. Three to four months following this, residents were subjected to specific nontechnical skills training involving 2 simple team-based laparoscopic tasks. They then practiced a further 4 to 6 hours on the virtual reality trainer. A repeat postintervention laparoscopic cholecystectomy was then performed 3 to 4 months after nontechnical skills training. Both the preintervention and postintervention laparoscopic cholecystectomies were audiovisually recorded and then evaluated by 2 independent surgeons in a blinded fashion. Technical skills were assessed using objective structured assessment of technical skills (OSATS) and a technique specific rating scale (TRS) that we developed for laparoscopic cholecystectomy. Nontechnical skills were assessed using nontechnical skills for surgeons (NOTSS). Residents also completed a survey at the beginning and end of the training. Tertiary care, university based teaching institution. A total of 9 general surgery residents at the intern level. The mean OSATS score improved from 13.7 ± 1.24 to 26.7 ± 0.31 (p < 0.001), the mean TRS score improved from 6 ± 0.46 to 13.1 ± 0.36 (p < 0.001) and the mean NOTSS score improved from 21.7 ± 1.83 to 36.3 ± 0.87 (p < 0.001) following the training. There was a strong correlation between OSATS and NOTSS scores (Pearson's R = 0.98) and TRS and NOTSS (R = 0.94). The inter-rater agreement was 0.79 for NOTSS, 0.9 for OSATS, and 0.82 for TRS. Following completion of the training, residents self-reported improvements in exchanging information (p < 0.01), coordinating activities (p < 0.01) and coping with pressure in the operating room (p < 0.001). Simple, team-based nontechnical skills training for laparoscopic cholecystectomy that was separate from technical skills training led to a sustained increase in residents' nontechnical skills 3 to 4 months after training. This was associated with a self-reported improvement in many nontechnical skills based on resident survey. Based on these results, we recommend that such designated nontechnical skills training is a valid alternative to other methods such as coaching and debriefing. We, therefore, plan to continue our efforts to develop team-based simulation tasks aimed at improving nontechnical skills for multiple surgical modalities. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Comprehensive analysis of Arabidopsis expression level polymorphisms with simple inheritance
Plantegenet, Stephanie; Weber, Johann; Goldstein, Darlene R; Zeller, Georg; Nussbaumer, Cindy; Thomas, Jérôme; Weigel, Detlef; Harshman, Keith; Hardtke, Christian S
2009-01-01
In Arabidopsis thaliana, gene expression level polymorphisms (ELPs) between natural accessions that exhibit simple, single locus inheritance are promising quantitative trait locus (QTL) candidates to explain phenotypic variability. It is assumed that such ELPs overwhelmingly represent regulatory element polymorphisms. However, comprehensive genome-wide analyses linking expression level, regulatory sequence and gene structure variation are missing, preventing definite verification of this assumption. Here, we analyzed ELPs observed between the Eil-0 and Lc-0 accessions. Compared with non-variable controls, 5′ regulatory sequence variation in the corresponding genes is indeed increased. However, ∼42% of all the ELP genes also carry major transcription unit deletions in one parent as revealed by genome tiling arrays, representing a >4-fold enrichment over controls. Within the subset of ELPs with simple inheritance, this proportion is even higher and deletions are generally more severe. Similar results were obtained from analyses of the Bay-0 and Sha accessions, using alternative technical approaches. Collectively, our results suggest that drastic structural changes are a major cause for ELPs with simple inheritance, corroborating experimentally observed indel preponderance in cloned Arabidopsis QTL. PMID:19225455
Analysis of External Treatment Methods and Technical Characteristics of External Treatment
NASA Astrophysics Data System (ADS)
Zhang, Rui; Miao, Mingsan; Bai, Ming
2018-01-01
Chinese medicine external therapy is a treatment method of Chinese medicine with Chinese characteristics. The effect of traditional Chinese medicine external treatment, convenient operation, external treatment and technology has great prospects for development. The traditional Chinese medicine external treatment method and technical characteristics were analyzed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Honeycutt, M.E.; Jarvis, A.S.; McFarland, V.A.
1995-07-01
This technical note is the third in a series of three that outline and describe the principal methods that have been developed to test the potential of environmental contaminants to cause mutagenic, carcinogenic, and teratogenic effects. The first in this series (EEDP-04-24) describes methods used to discern genotoxic effects at the sub cellular level, while the second (EEDP-04-25) describes methods used to discern genotoxic effects at the cellular and organ/organism level. Recent literature citations for each topic referenced in this series of technical notes are provided in this technical note, in addition to a glossary of terms. The information inmore » these technical notes is intended to provide Corps of Engineers personnel with a working knowledge of the terminology and conceptual basis of genotoxicity testing. To develop an improved understanding of the concepts of genotoxicity, readers are encouraged to review A Primer in Genotoxicity (Jarvis, Reilly, and Lutz 1993), presented in Volume D-93-3 of the Environmental Effects of Dredging information exchange bulletin.« less
ERIC Educational Resources Information Center
Bruce, Bertram
A complete analysis of a story's structure must rely on more than a simple grammar of story components; it requires a consideration of the characters' plans as they are stated or implied in the story. Furthermore, these plans are recognized as the characters' beliefs, and beliefs about interactions among plans are crucial determinants of a story's…
Real-Time Optimization of Distribution Grids for Increased Flexibility and
ensure a stable system operation. Now let's go a little bit to the math, because there are some technical math. This one looks very complicated, but it's actually very simple, because, for example, you take stability and optimality. However, I'm not going to delve into the math. I'm going to move to some test
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karpov, A. S.
2013-01-15
A computer procedure for simulating magnetization-controlled dc shunt reactors is described, which enables the electromagnetic transients in electric power systems to be calculated. It is shown that, by taking technically simple measures in the control system, one can obtain high-speed reactors sufficient for many purposes, and dispense with the use of high-power devices for compensating higher harmonic components.
Preventing Seal Leak During Negative Pressure Wound Therapy Near External Fixators: A Technical Tip.
Mannino, Brian J; Pullen, Michael W; Gaines, Robert
2017-03-01
Negative pressure wound therapy is an effective tool for the treatment of open wounds. Occasionally these wounds are associated with injuries or procedures that require treatment with an external fixator. This article shows how a simple, inexpensive, and commercially available product can be used to prevent loss of suction around external fixator pins within the negative pressure wound treatment area.
Toward a Natural Speech Understanding System
1989-10-01
WALTER J. SENUS Technical Director Directorate of Intelligence & Reconnaissance FOR THE COMMANDER JAMES W. HYDE III V Directorate of Plans & Programs ...applicable) Human Resources Laboratory F30602-81-C-0193 8 . ADDRESS (City, State, and ZIP Code) 10. SOURCE OF FUNDING NUMBERS PROGRAM PROJECT TASK WORK...error rates for distinctive words produced in isolation by a single speaker, and their simple programming requirements. Template-matching systems rank
R. Haggerty
2013-01-01
In this technical note, a steady-state analytical solution of concentrations of a parent solute reacting to a daughter solute, both of which are undergoing transport and multirate mass transfer, is presented. Although the governing equations are complicated, the resulting solution can be expressed in simple terms. A function of the ratio of concentrations, In (daughter...
Chips: A Tool for Developing Software Interfaces Interactively.
1987-10-01
of the application through the objects on the screen. Chips makes this easy by supplying simple and direct access to the source code and data ...object-oriented programming, user interface management systems, programming environments. Typographic Conventions Technical terms appearing in the...creating an environment in which we could do our work. This project could not have happened without him. Jeff Bonar started and managed the Chips
Using a Model of Verbal Art to Analyse the Visual: Analysing Multimodal Texts in Secondary English
ERIC Educational Resources Information Center
Ravelli, Louise
2016-01-01
Multimodal texts are now part of the curriculum for school English, but they are by their nature inherently complex, and pose many challenges for the classroom. Not least is finding a way to manage the technical complexity of accounting for these texts, as well as finding a way to move students beyond simple observation and description to critical…
Spacecraft Navigation Using X-ray Pulsars
2006-01-01
95FEATURED RESEARCH 2006 NRL REVIEW Spacecraft Navigation Using X-ray Pulsars P.S. Ray, K.S. Wood, and B.F. Phlips E.O. Hulburt Center for Space...satellites and computes the range (technically pseudorange) to each satellite Pulsars are the collapsed remnants of massive stars that have become...relatively simple structure, pulsars are exceptionally stable rotators whose timing stability rivals that of conventional atomic clocks. A navigation
ERIC Educational Resources Information Center
Lowe, N. K., Ed.
This document provides technical information and simple instructions for constructing 84 different pieces of science equipment. Each entry includes: (1) name of item; (2) purpose of the equipment; (3) person who submitted the information; (4) line drawing of prototype; (5) list of low-cost materials needed; (6) construction procedures; (7)…
Technique for Predicting the Radio Frequency Field Strength Inside an Enclosure
NASA Technical Reports Server (NTRS)
Hallett, Michael P.; Reddell, Jerry P.
1997-01-01
This technical memo represents a simple analytical technique for predicting the Radio Frequency (RF) field inside an enclosed volume in which radio frequency occurs. The technique was developed to predict the RF field strength within a launch vehicle fairing in which some payloads desire to launch with their telemetry transmitter radiating. This technique considers both the launch vehicle and the payload aspects.
Adaptive Backoff Synchronization Techniques
1989-07-01
The Simple Code. Technical Report, Lawrence Livermore Laboratory, February 1978. [6] F. Darems-Rogers, D. A. George, V. A. Norton, and G . F. Pfister...Heights, November 1986. 20 [7] Daniel Gajski , David Kuck, Duncan Lawrie, and Ahmed Saleh. Cedar - A Large Scale Multiprocessor. In International...17] Janak H. Patel. Analysis of Multiprocessors with Private Cache Memories. IEEE Transactions on Com- puters, C-31(4):296-304, April 1982. [18] G
NASA Astrophysics Data System (ADS)
Kuzin, Evgeny G.; Gerike, Boris L.; Drozdenko, Yuriy V.; Lupiy, Michael G.; Grigoryeva, Natalya V.
2017-10-01
The article reviews the issues of complex use of methods of technical diagnostics of gearboxes for belt conveyors, with the aim of creating an effective system of maintenance. The article is showing the results of the evaluation of the technical condition of the drives of belt conveyors based on vibration monitoring and thermal parameters, and analysis of lubricating oil.
Lee, Peter; Bollensdorff, Christian; Quinn, T. Alexander; Wuskell, Joseph P.; Loew, Leslie M.; Kohl, Peter
2011-01-01
Background Simultaneous optical mapping of multiple electrophysiologically relevant parameters in living myocardium is desirable for integrative exploration of mechanisms underlying heart rhythm generation under normal and pathophysiologic conditions. Current multiparametric methods are technically challenging, usually involving multiple sensors and moving parts, which contributes to high logistic and economic thresholds that prevent easy application of the technique. Objective The purpose of this study was to develop a simple, affordable, and effective method for spatially resolved, continuous, simultaneous, and multiparametric optical mapping of the heart, using a single camera. Methods We present a new method to simultaneously monitor multiple parameters using inexpensive off-the-shelf electronic components and no moving parts. The system comprises a single camera, commercially available optical filters, and light-emitting diodes (LEDs), integrated via microcontroller-based electronics for frame-accurate illumination of the tissue. For proof of principle, we illustrate measurement of four parameters, suitable for ratiometric mapping of membrane potential (di-4-ANBDQPQ) and intracellular free calcium (fura-2), in an isolated Langendorff-perfused rat heart during sinus rhythm and ectopy, induced by local electrical or mechanical stimulation. Results The pilot application demonstrates suitability of this imaging approach for heart rhythm research in the isolated heart. In addition, locally induced excitation, whether stimulated electrically or mechanically, gives rise to similar ventricular propagation patterns. Conclusion Combining an affordable camera with suitable optical filters and microprocessor-controlled LEDs, single-sensor multiparametric optical mapping can be practically implemented in a simple yet powerful configuration and applied to heart rhythm research. The moderate system complexity and component cost is destined to lower the threshold to broader application of functional imaging and to ease implementation of more complex optical mapping approaches, such as multiparametric panoramic imaging. A proof-of-principle application confirmed that although electrically and mechanically induced excitation occur by different mechanisms, their electrophysiologic consequences downstream from the point of activation are not dissimilar. PMID:21459161
Discrete is it enough? The revival of Piola-Hencky keynotes to analyze three-dimensional Elastica
NASA Astrophysics Data System (ADS)
Turco, Emilio
2018-04-01
Complex problems such as those concerning the mechanics of materials can be confronted only by considering numerical simulations. Analytical methods are useful to build guidelines or reference solutions but, for general cases of technical interest, they have to be solved numerically, especially in the case of large displacements and deformations. Probably continuous models arose for producing inspiring examples and stemmed from homogenization techniques. These techniques allowed for the solution of some paradigmatic examples but, in general, always require a discretization method for solving problems dictated by the applications. Therefore, and also by taking into account that computing powers are nowadays more largely available and cheap, the question arises: why not using directly a discrete model for 3D beams? In other words, it could be interesting to formulate a discrete model without using an intermediate continuum one, as this last, at the end, has to be discretized in any case. These simple considerations immediately evoke some very basic models developed many years ago when the computing powers were practically inexistent but the problem of finding simple solutions to beam deformation problem was already an emerging one. Actually, in recent years, the keynotes of Hencky and Piola attracted a renewed attention [see, one for all, the work (Turco et al. in Zeitschrift für Angewandte Mathematik und Physik 67(4):1-28, 2016)]: generalizing their results, in the present paper, a novel directly discrete three-dimensional beam model is presented and discussed, in the framework of geometrically nonlinear analysis. Using a stepwise algorithm based essentially on Newton's method to compute the extrapolations and on the Riks' arc-length method to perform the corrections, we could obtain some numerical simulations showing the computational effectiveness of presented model: Indeed, it presents a convenient balance between accuracy and computational cost.
Tabrizi, Jafar Sadegh; Somi, Mohammad Hossein; Asghari, Sima; Asghari Jafarabadi, Mohammad; Gharibi, Farid; Alidoost, Saeideh
2015-01-01
The Inflammatory Bowel Disease (IBD) is considered as one of the chronic diseasesre-quiring complicated treatment. This study aimed to assess technical quality of providing care for pa-tients with IBD. This cross-sectional study was conducted on 94 people with IBD using interviews and simple random sampling methods in Gastroenterology, Endoscopy and clinic of Imam Reza Hospital and Golgasht Clinic in Tabriz in 2012. The data collection tool was a researcher-designed questionnaire whose validity and reliability had been confirmed. In order to investigate the statistical relationship between the background variables and compliance with the standards the Chi-square test was applied using SPSS 17 Software. "visit by the physician" and "diet advice by the dietitian" have had the highest and the lowest levels of compliance with the standard respectively, and "the care related to the disease exacerbation" and "the care provided by the other physicians" were not compatible with the standards in 80% of the cases. Data analyses also showed that there was a significant relationship between participant's age, job, education and the smoking status and compliance of some care with the relevant standards (P<0.05). The results indicate a substantial gap between provided care for the people with IBD and the relevant standards. This indicates the areas that need of improvement and requires the serious attention of the authorities.
El Khattabi, Laïla Allach; Rouillac-Le Sciellour, Christelle; Le Tessier, Dominique; Luscan, Armelle; Coustier, Audrey; Porcher, Raphael; Bhouri, Rakia; Nectoux, Juliette; Sérazin, Valérie; Quibel, Thibaut; Mandelbrot, Laurent; Tsatsaris, Vassilis
2016-01-01
Objective NIPT for fetal aneuploidy by digital PCR has been hampered by the large number of PCR reactions needed to meet statistical requirements, preventing clinical application. Here, we designed an octoplex droplet digital PCR (ddPCR) assay which allows increasing the number of available targets and thus overcomes statistical obstacles. Method After technical optimization of the multiplex PCR on mixtures of trisomic and euploid DNA, we performed a validation study on samples of plasma DNA from 213 pregnant women. Molecular counting of circulating cell-free DNA was performed using a mix of hydrolysis probes targeting chromosome 21 and a reference chromosome. Results The results of our validation experiments showed that ddPCR detected trisomy 21 even when the sample’s trisomic DNA content is as low as 5%. In a validation study of plasma samples from 213 pregnant women, ddPCR discriminated clearly between the trisomy 21 and the euploidy groups. Conclusion Our results demonstrate that digital PCR can meet the requirements for non-invasive prenatal testing of trisomy 21. This approach is technically simple, relatively cheap, easy to implement in a diagnostic setting and compatible with ethical concerns regarding access to nucleotide sequence information. These advantages make it a potential technique of choice for population-wide screening for trisomy 21 in pregnant women. PMID:27167625
Dorafshar, Amir H; Januszyk, Michael; Song, David H
2010-08-01
Techniques for autologous breast reconstruction have evolved to minimize donor-site morbidity and reduce flap-specific complications. When available, the superficial inferior epigastric artery (SIEA) flap represents the optimal method to achieve the former. However, many microsurgeons have been reluctant to adopt this procedure due to technical challenges inherent to the surgery, as well as concerns with the intrinsic capacity of the superficial vessel system to adequately support this flap. This article sets forth a simple approach to the SIEA flap harvest and demonstrates that favorable results may be achieved even for small caliber vessels. A total of 46 patients underwent 53 SIEA breast reconstructions over a 6-year period using a modified approach for pedicle dissection and arterial inclusion criteria solely on the basis of presence of a palpable pulse. Average pedicle length harvested for all SIEA flaps was 6.07 cm; and mean arterial (0.96 mm) and venous (2.27 mm) diameters represent the lowest published values. Three flaps (5.7%) demonstrated fat necrosis or partial flap necrosis, with one (1.9%) complete flap loss. These results compare favorably with those of previous SIEA series employing diameter-based selection criteria, suggesting that the presence of a palpable arterial pulse may be sufficient to permit successful utilization of this flap. (c) Thieme Medical Publishers.
Balichev, Iu
1997-01-01
To investigation were submitted the particularities of the process of visual perception of technical drawings and schemes in advanced and backward pupils, who were mastering the specialties of "building and architecture", "hydroconstruction", "transport construction", "geodesy". The time was registered, which was necessary to advanced and backward pupils for unveiling the different elements in the drawing, scheme, and such attributes of the drawing as: orientation, length, curves of the lined, the boundary between them; time for identification of the specific designations, symbols, group of symbols, elements of the sketch from the simple to the complex ones. The results of the investigations revealed that in the advanced pupils the perception (unveiling) of the different elements of the technical drawing proceeded very rapidly, almost automatically. In the backward pupils this process elapsed reliably more slowly. It was demonstrated that the growing up pupils, who were distinguished with more rapid perception of the different elements of the drawing (advanced ones) more rapidly and more exactly dealt with solution of the technical tasks as compared with these, who more slowly unveiled the looked for elements (backwardness). Some other individual particularities were also established with respect to the visual perception of the elements of the technical drawing and its properties in advanced and backward pupils who were mastering the investigated professions.
Design and Delivery of Technical Module for the Business Intelligence Course
ERIC Educational Resources Information Center
Wang, Shouhong; Wang, Hai
2013-01-01
IS programs are increasingly being called on to offer courses in business intelligence. This article presents the pedagogical design and the delivery method of a practicable technical module for a non-technically oriented Business Intelligence course. It is a tutorial for the instructors who wish to incorporate a practical technical element in…
Analysis of the Technical Writing Profession through the DACUM Process.
ERIC Educational Resources Information Center
Nolan, Timothy; Green, Marc
To help develop a curriculum program for technical writers, Cincinnati Technical College used the Developing a Curriculum (DACUM) method to produce a technical writing skills profile. DACUM develops an occupation analysis through a modified brainstorming process by a panel of expert workers under the direction of a qualified coordinator. This…
Ada Software Design Methods Formulation.
1982-10-01
Programmer technical 2018 Principle Scientific Programmer technical 2020 Principle Scientif:c Programmer tnchnical 3001 Junior Programns. entry level...0.570 156 6010-. I---. 0.684 7 1031------------- 0.481 77 3119-. 0.620 94 4034-. ----- 0.696 90 4027-. -- ’---- 0.759 31 2018 -. I-’" 0.823 142 5063-. I...1094-2 0-117 cluster 4 2007 Senior Scientific Programmer technical 2016 Scientific Programmer technical 1080 Senior Software Engineer technical 2018
Using case studies to teach an engineering technology technical writing class
NASA Technical Reports Server (NTRS)
Green, M. M.
1981-01-01
The use of the case method in teaching various technical communication skills is described. Features of the method considered include: solving communication problems, identifying an audience, planning written communications, presenting written communications, and using visual aids.
HIRAYAMA, Hiroki; KAGEYAMA, Soichi; MORIYASU, Satoru; SAWAI, Ken; MINAMIHASHI, Akira
2013-01-01
Abstract In domestic animals of the family Bovidae, sex preselection of offspring has been demanded for convenience of milk/beef production and animal breeding. Development of the nonsurgical embryo transfer technique and sexing methods of preimplantation embryos made it possible. Sexing based on detection of Y chromosome-specific DNA sequences is considered the most reliable method to date. PCR enables amplification of a target sequence from a small number of blastomeres. However, it requires technical skill and is time consuming. Furthermore, PCR has the risk of false positives because of DNA contamination during handling of the PCR products in duplicate PCR procedures and/or electrophoresis. Therefore, for embryo sexing to become widely used in the cattle embryo transfer industry, a simple, rapid and precise sexing method needs to be developed. Loop-mediated isothermal amplification (LAMP) is a novel DNA amplification method, and the reaction is carried out under isothermal conditions (range, 60 to 65 C) using DNA polymerase with strand displacement activity. When the target DNA is amplified by LAMP, a white precipitate derived from magnesium pyrophosphate (a by-product of the LAMP reaction) is observed. It is noteworthy that LAMP does not need special reagents or electrophoresis to detect the amplified DNA. This review describes the development and application of an embryo sexing method using LAMP in cattle and water buffaloes. PMID:23965599
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kaiser, Brooke LD; Wunschel, David S.; Sydor, Michael A.
2015-08-07
Proteomic analysis of bacterial samples provides valuable information about cellular responses and functions under different environmental pressures. Proteomic analysis is dependent upon efficient extraction of proteins from bacterial samples without introducing bias toward extraction of particular protein classes. While no single method can recover 100% of the bacterial proteins, selected protocols can improve overall protein isolation, peptide recovery, or enrich for certain classes of proteins. The method presented here is technically simple and does not require specialized equipment such as a mechanical disrupter. Our data reveal that for particularly challenging samples, such as B. anthracis Sterne spores, trichloroacetic acid extractionmore » improved the number of proteins identified within a sample compared to bead beating (714 vs 660, respectively). Further, TCA extraction enriched for 103 known spore specific proteins whereas bead beating resulted in 49 unique proteins. Analysis of C. botulinum samples grown to 5 days, composed of vegetative biomass and spores, showed a similar trend with improved protein yields and identification using our method compared to bead beating. Interestingly, easily lysed samples, such as B. anthracis vegetative cells, were equally as effectively processed via TCA and bead beating, but TCA extraction remains the easiest and most cost effective option. As with all assays, supplemental methods such as implementation of an alternative preparation method may provide additional insight to the protein biology of the bacteria being studied.« less
How to approach the ENS: various ways to analyse motility disorders in situ and in vitro.
Schäfer, K-H; Hagl, C I; Wink, E; Holland-Cunz, S; Klotz, M; Rauch, U; Waag, K-L
2003-06-01
Motility disorders of the human intestine are so variable that they cannot be diagnosed by just one technique. Their aetiology is obviously so varied that they have to be approached with a broad range of technical methods. These reach from the simple haematoxylin-stained section to the isolation of stem or precursor cells. In this study, various methods to investigate the enteric nervous system and its surrounding tissue are demonstrated. While sections from paraffin-embedded material or cryostat sections provide only a two-dimensional perspective of the ENS, the whole-mount method yields three-dimensional perspectives of large areas of the gut wall. The three-dimensional impression can even be enhanced by electron microscopy of the isolated ENS. Dynamical aspects of ENS development can be tackled by in vitro studies. The myenteric plexus can be isolated and cultivated under the influence of the microenvironment (protein extracts). Although the postnatal myenteric plexus is not fully developed, the choice of embryological neuronal cells seems to be more effective for certain approaches. They can be isolated from the embryonic mouse gut and cultivated under the influence of various factors. This method seems to us a valuable tool for the investigation of the aetiology of motility disorders, although only a "complete" approach which considers all available methods will yield at the end a clear understanding which might lead to new therapeutical concepts.
Interactive Methods of Teaching Physics at Technical Universities
ERIC Educational Resources Information Center
Krišták, L'uboš; Nemec, Miroslav; Danihelová, Zuzana
2014-01-01
The paper presents results of "non-traditional" teaching of the basic course of Physics in the first year of study at the Technical University in Zvolen, specifically teaching via interactive method enriched with problem tasks and experiments. This paper presents also research results of the use of the given method in conditions of…
Technical Notes on the Multifactor Method of Elementary School Closing.
ERIC Educational Resources Information Center
Puleo, Vincent T.
This report provides preliminary technical information on a method for analyzing the factors involved in the closing of elementary schools. Included is a presentation of data and a brief discussion bearing on descriptive statistics, reliability, and validity. An intercorrelation matrix is also examined. The method employs 9 factors that have a…
A SIMPLE METHOD FOR THE EXTRACTION AND QUANTIFICATION OF PHOTOPIGMENTS FROM SYMBIODINIUM SPP.
John E. Rogers and Dragoslav Marcovich. Submitted. Simple Method for the Extraction and Quantification of Photopigments from Symbiodinium spp.. Limnol. Oceanogr. Methods. 19 p. (ERL,GB 1192).
We have developed a simple, mild extraction procedure using methanol which, when...
Kawakubo, Kazumichi; Kawakami, Hiroshi; Toyokawa, Yoshihide; Otani, Koichi; Kuwatani, Masaki; Abe, Yoko; Kawahata, Shuhei; Kubo, Kimitoshi; Kubota, Yoshimasa; Sakamoto, Naoya
2015-01-01
Endoscopic double self-expandable metallic stent (SEMS) placement by the partial stent-in-stent (PSIS) method has been reported to be useful for the management of unresectable hilar malignant biliary obstruction. However, it is technically challenging, and the optimal SEMS for the procedure remains unknown. The aim of this study was to identify the risk factors for technical failure of endoscopic double SEMS placement for unresectable malignant hilar biliary obstruction (MHBO). Between December 2009 and May 2013, 50 consecutive patients with MHBO underwent endoscopic double SEMS placement by the PSIS method. We retrospectively evaluated the rate of successful double SEMS placement and identified the risk factors for technical failure. The technical success rate for double SEMS placement was 82.0% (95% confidence interval [CI]: 69.2-90.2). On univariate analysis, the rate of technical failure was high in patients with metastatic disease and unilateral placement. Multivariate analysis revealed that metastatic disease was a significant risk factor for technical failure (odds ratio: 9.63, 95% CI: 1.11-105.5). The subgroup analysis after double guidewire insertion showed that the rate of technical success was higher in the laser-cut type SEMS with a large mesh and thick delivery system than in the braided type SEMS with a small mesh and thick delivery system. Metastatic disease was a significant risk factor for technical failure of double SEMS placement for unresectable MHBO. The laser-cut type SEMS with a large mesh and thin delivery system might be preferable for the PSIS procedure. © 2014 Japanese Society of Hepato-Biliary-Pancreatic Surgery.
Moving towards the goals of FP2020 - classifying contraceptives.
Festin, Mario Philip R; Kiarie, James; Solo, Julie; Spieler, Jeffrey; Malarcher, Shawn; Van Look, Paul F A; Temmerman, Marleen
2016-10-01
With the renewed focus on family planning, a clear and transparent understanding is needed for the consistent classification of contraceptives, especially in the commonly used modern/traditional system. The World Health Organization Department of Reproductive Health and Research and the United States Agency for International Development (USAID) therefore convened a technical consultation in January 2015 to address issues related to classifying contraceptives. The consultation defined modern contraceptive methods as having a sound basis in reproductive biology, a precise protocol for correct use and evidence of efficacy under various conditions based on appropriately designed studies. Methods in country programs like Fertility Awareness Based Methods [such as Standard Days Method (SDM) and TwoDay Method], Lactational Amenorrhea Method (LAM) and emergency contraception should be reported as modern. Herbs, charms and vaginal douching are not counted as contraceptive methods as they have no scientific basis in preventing pregnancy nor are in country programs. More research is needed on defining and measuring use of emergency contraceptive methods, to reflect their contribution to reducing unmet need. The ideal contraceptive classification system should be simple, easy to use, clear and consistent, with greater parsimony. Measurement challenges remain but should not be the driving force to determine what methods are counted or reported as modern or not. Family planning programs should consider multiple attributes of contraceptive methods (e.g., level of effectiveness, need for program support, duration of labeled use, hormonal or nonhormonal) to ensure they provide a variety of methods to meet the needs of women and men. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
Technical Note: Approximate Bayesian parameterization of a complex tropical forest model
NASA Astrophysics Data System (ADS)
Hartig, F.; Dislich, C.; Wiegand, T.; Huth, A.
2013-08-01
Inverse parameter estimation of process-based models is a long-standing problem in ecology and evolution. A key problem of inverse parameter estimation is to define a metric that quantifies how well model predictions fit to the data. Such a metric can be expressed by general cost or objective functions, but statistical inversion approaches are based on a particular metric, the probability of observing the data given the model, known as the likelihood. Deriving likelihoods for dynamic models requires making assumptions about the probability for observations to deviate from mean model predictions. For technical reasons, these assumptions are usually derived without explicit consideration of the processes in the simulation. Only in recent years have new methods become available that allow generating likelihoods directly from stochastic simulations. Previous applications of these approximate Bayesian methods have concentrated on relatively simple models. Here, we report on the application of a simulation-based likelihood approximation for FORMIND, a parameter-rich individual-based model of tropical forest dynamics. We show that approximate Bayesian inference, based on a parametric likelihood approximation placed in a conventional MCMC, performs well in retrieving known parameter values from virtual field data generated by the forest model. We analyze the results of the parameter estimation, examine the sensitivity towards the choice and aggregation of model outputs and observed data (summary statistics), and show results from using this method to fit the FORMIND model to field data from an Ecuadorian tropical forest. Finally, we discuss differences of this approach to Approximate Bayesian Computing (ABC), another commonly used method to generate simulation-based likelihood approximations. Our results demonstrate that simulation-based inference, which offers considerable conceptual advantages over more traditional methods for inverse parameter estimation, can successfully be applied to process-based models of high complexity. The methodology is particularly suited to heterogeneous and complex data structures and can easily be adjusted to other model types, including most stochastic population and individual-based models. Our study therefore provides a blueprint for a fairly general approach to parameter estimation of stochastic process-based models in ecology and evolution.
[Analysis on the accuracy of simple selection method of Fengshi (GB 31)].
Li, Zhixing; Zhang, Haihua; Li, Suhe
2015-12-01
To explore the accuracy of simple selection method of Fengshi (GB 31). Through the study of the ancient and modern data,the analysis and integration of the acupuncture books,the comparison of the locations of Fengshi (GB 31) by doctors from all dynasties and the integration of modern anatomia, the modern simple selection method of Fengshi (GB 31) is definite, which is the same as the traditional way. It is believed that the simple selec tion method is in accord with the human-oriented thought of TCM. Treatment by acupoints should be based on the emerging nature and the individual difference of patients. Also, it is proposed that Fengshi (GB 31) should be located through the integration between the simple method and body surface anatomical mark.
ERIC Educational Resources Information Center
Overlock, Terrence H., Sr.
To determine the effect of collaborative learning methods on the success rate of physics students at Northern Maine Technical College (NMTC), a study was undertaken to compare the mean final exam scores of a students in a physics course taught by traditional lecture/lab methods to those in a group taught by collaborative techniques. The…
Increasing the technical level of mining haul trucks
NASA Astrophysics Data System (ADS)
Voronov, Yuri; Voronov, Artyom; Grishin, Sergey; Bujankin, Alexey
2017-11-01
Theoretical and methodological fundamentals of mining haul trucks optimal design are articulated. Methods based on the systems approach to integrated assessment of truck technical level and methods for optimization of truck parameters depending on performance standards are provided. The results of using these methods are given. The developed method allows not only assessing the truck technical levels but also choosing the most promising models and providing quantitative evaluations of the decisions to be made at the design stage. These areas are closely connected with the problem of improvement in the industrial output quality, which, being a part of the widely spread in Western world "total quality control" ideology, is one of the major issues for the Russian economy.
Application of Support Vector Machine to Forex Monitoring
NASA Astrophysics Data System (ADS)
Kamruzzaman, Joarder; Sarker, Ruhul A.
Previous studies have demonstrated superior performance of artificial neural network (ANN) based forex forecasting models over traditional regression models. This paper applies support vector machines to build a forecasting model from the historical data using six simple technical indicators and presents a comparison with an ANN based model trained by scaled conjugate gradient (SCG) learning algorithm. The models are evaluated and compared on the basis of five commonly used performance metrics that measure closeness of prediction as well as correctness in directional change. Forecasting results of six different currencies against Australian dollar reveal superior performance of SVM model using simple linear kernel over ANN-SCG model in terms of all the evaluation metrics. The effect of SVM parameter selection on prediction performance is also investigated and analyzed.
Krummel, Thomas M
2006-11-01
Progress in surgical science has been characterized by a continuous cycle of innovation from bedside to bench to bedside. Beginning 30,000 years ago with the first bone needles to surgical lasers and robotics of today, each quantum leap has resulted from the convergence of technical advances and creative surgeons, but always defined by an attitude of care toward the sick. One of the most innovative pediatric surgeons, Dr. Mark Ravitch, elucidated some simple yet profound principles in the precise answer to the question "What is Surgery?" This section outlines some simple concepts summarized as "Ravitch's Rules," which provide a useful framework for clarity in understanding the past and illuminating the road ahead. Surgeons must be thoughtful in how they define themselves and their craft, ignoring technological advances at their own peril.
Heuristics and Biases in Military Decision Making
2010-10-01
rationality and is based on a linear, step-based model that generates a specific course of action and is useful for the examination of problems that...exhibit stability and are underpinned by assumptions of “technical- rationality .”5 The Army values MDMP as the sanctioned approach for solving...theory) which sought to describe human behavior as a rational maximization of cost-benefit decisions, Kahne- man and Tversky provided a simple
2000-04-01
system, 8 - experiments on a study of boundary layer spectrum infrared window). before boiling of glass- silicide coating. This simple 3. SAMPLES AND...dependencies of surface temperature of tested materials and make conclusions concerned joint gllass- silicide coating and anode power of generator...obtained using test stagnation point configuration. glass- silicide coating vs anode power of HF-generator. Temperature peak at constant power
Stochastic Simulations of Long-Range Forecasting Models. Volume 3. Technical Appendix
1975-10-31
short-term stress in the society; and the balance of coercive capabilities between regimes and dissidents. Of course, the particular measures...and complements the more simple measure of strain, the ratio DEFX/GDP. The concept stress refers to shortages or relative declines in the supply of...valued social, economic, or political goods. Stress was measured by Gurr and Duvall (1972) with, among others, the operational variable DEFX/ GDP
Thermal Theory of Combustion and Explosion. 3; Theory of Normal Flame Propagation
NASA Technical Reports Server (NTRS)
Semenov, N. N.
1942-01-01
The technical memorandum covers experimental data on flame propagation, the velocity of flame propagation, analysis of the old theoretical views of flame propagation, confirmation of the theory for simple reactions (theory of combustion of explosive substances and in particular nitroglycol), and check of the theory by example of a chain oxidizing reaction (theory of flame propagation in carbon monoxide, air and carbon monoxide - oxygen mixtures).
Measuring What Matters Workshop Report
2015-01-14
Measuring What Matters Workshop Report Katie Stewart Julia Allen Michelle Valdez Lisa Young January 2015 TECHNICAL NOTE CMU/SEI-2015-TN...the approach using a simple objective: teaching a child to properly brush his/her teeth. Next, we demonstrate the approach using a cybersecurity...Ensure you child’s teeth are healthy. G1: Ensure your child has everything needed to brush his/her teeth. G2: Ensure your child is brushing his
Measuring What Matters Workshop Report
2015-01-01
Measuring What Matters Workshop Report Katie Stewart Julia Allen Michelle Valdez Lisa Young January 2015 TECHNICAL NOTE CMU/SEI-2015-TN...the approach using a simple objective: teaching a child to properly brush his/her teeth. Next, we demonstrate the approach using a cybersecurity...Ensure you child’s teeth are healthy. G1: Ensure your child has everything needed to brush his/her teeth. G2: Ensure your child is brushing his
UV-VIS absorption spectroscopy: Lambert-Beer reloaded.
Mäntele, Werner; Deniz, Erhan
2017-02-15
UV-VIS absorption spectroscopy is used in almost every spectroscopy laboratory for routine analysis or research. All spectroscopists rely on the Lambert-Beer Law but many of them are less aware of its limitations. This tutorial discusses typical problems in routine spectroscopy that come along with technical limitations or careless selection of experimental parameters. Simple rules are provided to avoid these problems. Copyright © 2016 Elsevier B.V. All rights reserved.
Adaptive Backoff Synchronization Techniques
1989-06-01
The Simple Code. Technical Report, Lawrence Livermore Laboratory, February 1978. [6J F. Darems-Rogers, D. A. George, V. A. Norton, and G . F. Pfister...Heights, November 1986. 20 [7] Daniel Gajski , David Kuck, Duncan Lawrie, and Ahmed Saleh. Cedar - A Large Scale Multiprocessor. In International Conference...17] Janak H. Patel. Analysis of Multiprocessors with Private Cache Memories. IEEE Transactions on Com- puters, C-31(4):296-304, April 1982. [18] G
Technical Report for the Period 1 October 1987 - 30 September 1989
1990-03-01
low pass filter results. -dt dt specifies the sampling rate in seconds. -gin specifies .w file (binary waveform data) input. - gout specifies .w file...waves arriving at moderate incidence angles, * high signal-to-noise ratio (SNR). The following assumptions are made, for simplicity* * additive...spatially uncorrelated noise, * simple signal model, free of refraction and scattering effects. This study is limited to the case of a plane incident P
Nature as an engineer: one simple concept of a bio-inspired functional artificial muscle.
Schmitt, S; Haeufle, D F B; Blickhan, R; Günther, M
2012-09-01
The biological muscle is a powerful, flexible and versatile actuator. Its intrinsic characteristics determine the way how movements are generated and controlled. Robotic and prosthetic applications expect to profit from relying on bio-inspired actuators which exhibit natural (muscle-like) characteristics. As of today, when constructing a technical actuator, it is not possible to copy the exact molecular structure of a biological muscle. Alternatively, the question may be put how its characteristics can be realized with known mechanical components. Recently, a mechanical construct for an artificial muscle was proposed, which exhibits hyperbolic force-velocity characteristics. In this paper, we promote the constructing concept which is made by substantiating the mechanical design of biological muscle by a simple model, proving the feasibility of its real-world implementation, and checking their output both for mutual consistency and agreement with biological measurements. In particular, the relations of force, enthalpy rate and mechanical efficiency versus contraction velocity of both the construct's technical implementation and its numerical model were determined in quick-release experiments. All model predictions for these relations and the hardware results are now in good agreement with the biological literature. We conclude that the construct represents a mechanical concept of natural actuation, which is suitable for laying down some useful suggestions when designing bio-inspired actuators.
Salt, Alec N; Hale, Shane A; Plonkte, Stefan K R
2006-05-15
Measurements of drug levels in the fluids of the inner ear are required to establish kinetic parameters and to determine the influence of specific local delivery protocols. For most substances, this requires cochlear fluids samples to be obtained for analysis. When auditory function is of primary interest, the drug level in the perilymph of scala tympani (ST) is most relevant, since drug in this scala has ready access to the auditory sensory cells. In many prior studies, ST perilymph samples have been obtained from the basal turn, either by aspiration through the round window membrane (RWM) or through an opening in the bony wall. A number of studies have demonstrated that such samples are likely to be contaminated with cerebrospinal fluid (CSF). CSF enters the basal turn of ST through the cochlear aqueduct when the bony capsule is perforated or when fluid is aspirated. The degree of sample contamination has, however, not been widely appreciated. Recent studies have shown that perilymph samples taken through the round window membrane are highly contaminated with CSF, with samples greater than 2microL in volume containing more CSF than perilymph. In spite of this knowledge, many groups continue to sample from the base of the cochlea, as it is a well-established method. We have developed an alternative, technically simple method to increase the proportion of ST perilymph in a fluid sample. The sample is taken from the apex of the cochlea, a site that is distant from the cochlear aqueduct. A previous problem with sampling through a perforation in the bone was that the native perilymph rapidly leaked out driven by CSF pressure and was lost to the middle ear space. We therefore developed a procedure to collect all the fluid that emerged from the perforated apex after perforation. We evaluated the method using a marker ion trimethylphenylammonium (TMPA). TMPA was applied to the perilymph of guinea pigs either by RW irrigation or by microinjection into the apical turn. The TMPA concentration of the fluid sample was compared with that measured in perilymph prior to taking the sample using a TMPA-selective microelectrode sealed into ST. Data were interpreted with a finite element model of the cochlear fluids that was used to simulate each aspect of the experiment. The correction of sample concentration back to the perilymph concentration prior to sampling can be performed based on the known ST volume (4.7microL in the guinea pig) and the sample volume. A more precise correction requires some knowledge of the profile of drug distribution along the cochlear prior to sampling. This method of sampling from the apex is technically simple and provides a larger sample volume with a greater proportion of perilymph compared to sampling through the RW.
Salt, Alec N.; Hale, Shane A.; Plontke, Stefan K. R.
2006-01-01
Measurements of drug levels in the fluids of the inner ear are required to establish kinetic parameters and to determine the influence of specific local delivery protocols. For most substances, this requires cochlear fluids samples to be obtained for analysis. When auditory function is of primary interest, the drug level in the perilymph of scala tympani (ST) is most relevant, since drug in this scala has ready access to the auditory sensory cells. In many prior studies, ST perilymph samples have been obtained from the basal turn, either by aspiration through the round window membrane (RWM) or through an opening in the bony wall. A number of studies have demonstrated that such samples are likely to be contaminated with cerebrospinal fluid (CSF). CSF enters the basal turn of ST through the cochlear aqueduct when the bony capsule is perforated or when fluid is aspirated. The degree of sample contamination has, however, not been widely appreciated. Recent studies have shown that perilymph samples taken through the round window membrane are highly contaminated with CSF, with samples greater than 2 μL in volume containing more CSF than perilymph. In spite of this knowledge, many groups continue to sample from the base of the cochlea, as it is a well-established method. We have developed an alternative, technically simple method to increase the proportion of ST perilymph in a fluid sample. The sample is taken from the apex of the cochlea, a site that is distant from the cochlear aqueduct. A previous problem with sampling through a perforation in the bone was that the native perilymph rapidly leaked out driven by CSF pressure and was lost to the middle ear space. We therefore developed a procedure to collect all the fluid that emerged from the perforated apex after perforation. We evaluated the method using a marker ion trimethylphenylammonium (TMPA). TMPA was applied to the perilymph of guinea pigs either by RW irrigation or by microinjection into the apical turn. The TMPA concentration of the fluid sample was compared with that measured in perilymph prior to taking the sample using a TMPA-selective microelectrode sealed into ST. Data were interpreted with a finite element model of the cochlear fluids that was used to simulate each aspect of the experiment. The correction of sample concentration back to the perilymph concentration prior to sampling can be performed based on the known ST volume (4.7 μL in the guinea pig) and the sample volume. A more precise correction requires some knowledge of the profile of drug distribution along the cochlear prior to sampling. This method of sampling from the apex is technically simple and provides a larger sample volume with a greater proportion of perilymph compared to sampling through the RW. PMID:16310856
ERIC Educational Resources Information Center
Sanford, Brian A.; McCaslin, N. L.
2004-01-01
This study was designed to describe the frequency of professional development activities provided to part-time occupational and technical program faculty. Additionally, the perceptions of occupational education officers concerning the instructional professional development needs and their appropriate delivery method(s) for these faculty members…
ERIC Educational Resources Information Center
Stuebing, Karla K.; Fletcher, Jack M.; Branum-Martin, Lee; Francis, David J.
2012-01-01
This study used simulation techniques to evaluate the technical adequacy of three methods for the identification of specific learning disabilities via patterns of strengths and weaknesses in cognitive processing. Latent and observed data were generated and the decision-making process of each method was applied to assess concordance in…
Technical Feasibility Assessment of Lunar Base Mission Scenarios
NASA Astrophysics Data System (ADS)
Magelssen, Trygve ``Spike''; Sadeh, Eligar
2005-02-01
Investigation of the literature pertaining to lunar base (LB) missions and the technologies required for LB development has revealed an information gap that hinders technical feasibility assessment. This information gap is the absence of technical readiness levels (TRL) (Mankins, 1995) and information pertaining to the criticality of the critical enabling technologies (CETs) that enable mission success. TRL is a means of identifying technical readiness stages of a technology. Criticality is defined as the level of influence the CET has on the mission scenario. The hypothesis of this research study is that technical feasibility is a function of technical readiness and technical readiness is a function of criticality. A newly developed research analysis method is used to identify the technical feasibility of LB mission scenarios. A Delphi is used to ascertain technical readiness levels and CET criticality-to-mission. The research analysis method is applied to the Delphi results to determine the technical feasibility of the LB mission scenarios that include: observatory, science research, lunar settlement, space exploration gateway, space resource utilization, and space tourism. The CETs identified encompasses four major system level technologies of: transportation, life support, structures, and power systems. Results of the technical feasibility assessment show the observatory and science research LB mission scenarios to be more technical ready out of all the scenarios, but all mission scenarios are in very close proximity to each other in regard to criticality and TRL and no one mission scenario stands out as being absolutely more technically ready than any of the other scenarios. What is significant and of value are the Delphi results concerning CET criticality-to-mission and the TRL values evidenced in the Tables that can be used by anyone assessing the technical feasibility of LB missions.
Upile, Tahwinder; Jerjes, Waseem; Kafas, Panagiotis; Singh, Sandeep U; Sudhoff, Holger; Mahil, Jaspal; Sandison, Ann; Hopper, Colin
2009-01-01
Background Although much has been published for the development of cell lines, these were lab based and developed for scientific technical staff. Objective of review We present a simple and successful protocol for the development of cell lines and tissue harvesting for the clinical scientist. We also discuss the ethical implications of tissue retention and present a generic consent form. Conclusion The advantages of hospital-based cell line creation are numerous. We can be more certain that cell lines are developed from the particular tissues of interest and accurate anatomical and appropriate clinico-pathological control tissues are also harvested. We can also be certain of less cell line cross contamination. PMID:19344501
Technical manual for manufacturing autologous fibrin tissue adhesive.
Park, J J; Cintron, J R; Siedentop, K H; Orsay, C P; Pearl, R K; Nelson, R L; Abcarian, H
1999-10-01
The aim of this article is to provide a concise and simple technical manual for manufacturing autologous fibrin tissue adhesive derived from the precipitation of fibrinogen using a combination of ethanol and freezing for surgery. All materials and equipment needed to manufacture ethanol-based autologous fibrin tissue adhesive are listed. In addition, step-by-step instructions are provided to allow for easy and rapid fibrin adhesive production. Ethanol-based autologous fibrin tissue adhesive can be manufactured in under 60 minutes. Furthermore, at our institution the startup cost for manufacturing ethanol-based autologous fibrin tissue adhesive was under $2,500.00. Ethanol-based autologous fibrin tissue adhesive is a safe, reliable, and easily manufactured autologous fibrin tissue adhesive that can be made by a trained technician in any blood bank, pharmacy, or surgical laboratory.
Hemostatic powder spray: a new method for managing gastrointestinal bleeding
Papafragkakis, Haris; Ofori, Emmanuel; Ona, Mel A.; Krishnaiah, Mahesh; Duddempudi, Sushil; Anand, Sury
2015-01-01
Gastrointestinal bleeding is a leading cause of morbidity and mortality in the United States. The management of gastrointestinal bleeding is often challenging, depending on its location and severity. To date, widely accepted hemostatic treatment options include injection of epinephrine and tissue adhesives such as cyanoacrylate, ablative therapy with contact modalities such as thermal coagulation with heater probe and bipolar hemostatic forceps, noncontact modalities such as photodynamic therapy and argon plasma coagulation, and mechanical hemostasis with band ligation, endoscopic hemoclips, and over-the-scope clips. These approaches, albeit effective in achieving hemostasis, are associated with a 5–10% rebleeding risk. New simple, effective, universal, and safe methods are needed to address some of the challenges posed by the current endoscopic hemostatic techniques. The use of a novel hemostatic powder spray appears to be effective and safe in controlling upper and lower gastrointestinal bleeding. Although initial reports of hemostatic powder spray as an innovative approach to manage gastrointestinal bleeding are promising, further studies are needed to support and confirm its efficacy and safety. The aim of this study was to evaluate the technical feasibility, clinical efficacy, and safety of hemostatic powder spray (Hemospray, Cook Medical, Winston-Salem, North Carolina, USA) as a new method for managing gastrointestinal bleeding. In this review article, we performed an extensive literature search summarizing case reports and case series of Hemospray for the management of gastrointestinal bleeding. Indications, features, technique, deployment, success rate, complications, and limitations are discussed. The combined technical and clinical success rate of Hemospray was 88.5% (207/234) among the human subjects and 81.8% (9/11) among the porcine models studied. Rebleeding occurred within 72 hours post-treatment in 38 patients (38/234; 16.2%) and in three porcine models (3/11; 27.3%). No procedure-related adverse events were associated with the use of Hemospray. Hemospray appears to be a safe and effective approach in the management of gastrointestinal bleeding. PMID:26082803
Hemostatic powder spray: a new method for managing gastrointestinal bleeding.
Changela, Kinesh; Papafragkakis, Haris; Ofori, Emmanuel; Ona, Mel A; Krishnaiah, Mahesh; Duddempudi, Sushil; Anand, Sury
2015-05-01
Gastrointestinal bleeding is a leading cause of morbidity and mortality in the United States. The management of gastrointestinal bleeding is often challenging, depending on its location and severity. To date, widely accepted hemostatic treatment options include injection of epinephrine and tissue adhesives such as cyanoacrylate, ablative therapy with contact modalities such as thermal coagulation with heater probe and bipolar hemostatic forceps, noncontact modalities such as photodynamic therapy and argon plasma coagulation, and mechanical hemostasis with band ligation, endoscopic hemoclips, and over-the-scope clips. These approaches, albeit effective in achieving hemostasis, are associated with a 5-10% rebleeding risk. New simple, effective, universal, and safe methods are needed to address some of the challenges posed by the current endoscopic hemostatic techniques. The use of a novel hemostatic powder spray appears to be effective and safe in controlling upper and lower gastrointestinal bleeding. Although initial reports of hemostatic powder spray as an innovative approach to manage gastrointestinal bleeding are promising, further studies are needed to support and confirm its efficacy and safety. The aim of this study was to evaluate the technical feasibility, clinical efficacy, and safety of hemostatic powder spray (Hemospray, Cook Medical, Winston-Salem, North Carolina, USA) as a new method for managing gastrointestinal bleeding. In this review article, we performed an extensive literature search summarizing case reports and case series of Hemospray for the management of gastrointestinal bleeding. Indications, features, technique, deployment, success rate, complications, and limitations are discussed. The combined technical and clinical success rate of Hemospray was 88.5% (207/234) among the human subjects and 81.8% (9/11) among the porcine models studied. Rebleeding occurred within 72 hours post-treatment in 38 patients (38/234; 16.2%) and in three porcine models (3/11; 27.3%). No procedure-related adverse events were associated with the use of Hemospray. Hemospray appears to be a safe and effective approach in the management of gastrointestinal bleeding.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-29
... NUCLEAR WASTE TECHNICAL REVIEW BOARD Board Workshop: June 6-7, 2011--Arlington, Virginia; the U.S. Nuclear Waste Technical Review Board Will Hold a Workshop on Methods for Evaluating Nuclear Waste Streams... 1987, the U.S. Nuclear Waste Technical Review Board will hold a workshop on Monday, June 6, and Tuesday...
7 CFR 4280.115 - Construction planning and performing development.
Code of Federal Regulations, 2010 CFR
2010-01-01
... projects as applicable. For contracts of $200,000 or less, the simple contract method, as specified in... warranty documents. (e) Simple contract method. The simple contract method may be used for small projects... Agency and may be used only if they are customarily used in the area and protect the interest of the...
The construction and operation of a low-cost poultry waste digester.
Steinsberger, S C; Shih, J C
1984-05-01
A simple and low-cost poultry waste digester (PWD) was constructed to treat the waste from 4000 caged laying hens on University Research Unit No. 2 at North Carolina State University. The system was built basically of a plastic lining with insulation, a heating system, a hot-water tank, and other metering equipment. It was operated at 50 degrees C and pH 7.5-8.0. The initiation of methane production was achieved using the indigenous microflora in the poultry waste. At an optimal loading rate (7.5 kg volatile solids/m(3) day), the PWD produced biogas (55% methane) at a rate of 4.0 m(3)/m(3) day. The PWD was biologically stable and able to tolerate temporary overloads and shutdowns. A higher loading rate failed to maintain a high gas production rate and caused drops in methane content and pH value. Under optimal conditions, a positive energy balance was demonstrated with a net surplus of 50.6% of the gross energy. For methane production, the PWD system was proved to be technically feasible. The simple design and inexpensive materials used for this model could significantly reduce the cost of digestion compared to more conventional systems. More studies are needed to determine the durability, the required maintenance of the system, and the most economical method of biogas and solid residue utilization.
NASA Astrophysics Data System (ADS)
Michalik-Onichimowska, Aleksandra; Kern, Simon; Riedel, Jens; Panne, Ulrich; King, Rudibert; Maiwald, Michael
2017-04-01
Driven mostly by the search for chemical syntheses under biocompatible conditions, so called "click" chemistry rapidly became a growing field of research. The resulting simple one-pot reactions are so far only scarcely accompanied by an adequate optimization via comparably straightforward and robust analysis techniques possessing short set-up times. Here, we report on a fast and reliable calibration-free online NMR monitoring approach for technical mixtures. It combines a versatile fluidic system, continuous-flow measurement of 1H spectra with a time interval of 20 s per spectrum, and a robust, fully automated algorithm to interpret the obtained data. As a proof-of-concept, the thiol-ene coupling between N-boc cysteine methyl ester and allyl alcohol was conducted in a variety of non-deuterated solvents while its time-resolved behaviour was characterized with step tracer experiments. Overlapping signals in online spectra during thiol-ene coupling could be deconvoluted with a spectral model using indirect hard modeling and were subsequently converted to either molar ratios (using a calibration-free approach) or absolute concentrations (using 1-point calibration). For various solvents the kinetic constant k for pseudo-first order reaction was estimated to be 3.9 h-1 at 25 °C. The obtained results were compared with direct integration of non-overlapping signals and showed good agreement with the implemented mass balance.
NASA Astrophysics Data System (ADS)
Samadi, Reza
Technical textiles are increasingly being engineered and used in challenging applications, in areas such as safety, biomedical devices, architecture and others, where they must meet stringent demands including excellent and predictable load bearing capabilities. They also form the bases for one of the most widespread group of composite materials, fibre reinforced polymer-matrix composites (PMCs), which comprise materials made of stiff and strong fibres generally available in textile form and selected for their structural potential, combined with a polymer matrix that gives parts their shape. Manufacturing processes for PMCs and technical textiles, as well as parts and advanced textile structures must be engineered, ideally through simulation, and therefore diverse properties of the textiles, textile reinforcements and PMC materials must be available for predictive simulation. Knowing the detailed geometry of technical textiles is essential to predicting accurately the processing and performance properties of textiles and PMC parts. In turn, the geometry taken by a textile or a reinforcement textile is linked in an intricate manner to its constitutive behaviour. This thesis proposes, investigates and validates a general numerical tool for the integrated and comprehensive analysis of textile geometry and constitutive behaviour as required toward engineering applications featuring technical textiles and textile reinforcements. The tool shall be general with regards to the textiles modelled and the loading cases applied. Specifically, the work aims at fulfilling the following objectives: 1) developing and implementing dedicated simulation software for modelling textiles subjected to various load cases; 2) providing, through simulation, geometric descriptions for different textiles subjected to different load cases namely compaction, relaxation and shear; 3) predicting the constitutive behaviour of the textiles undergoing said load cases; 4) identifying parameters affecting the textile geometry and constitutive behaviour under evolving loading; 5) validating simulation results with experimental trials; and 6) demonstrating the applicability of the simulation procedure to textile reinforcements featuring large numbers of small fibres as used in PMCs. As a starting point, the effects of reinforcement configuration on the in-plane permeability of textile reinforcements, through-thickness thermal conductivity of PMCs and in-plane stiffness of unidirectional and bidirectional PMCs were quantified systematically and correlated with specific geometric parameters. Variability was quantified for each property at a constant fibre volume fraction. It was observed that variability differed strongly between properties; as such, the simulated behaviour can be related to variability levels seen in experimental measurements. The effects of the geometry of textile reinforcements on the aforementioned processing and performance properties of the textiles and PMCs made from these textiles was demonstrated and validated, but only for simple cases as thorough and credible geometric models were not available at the onset of this work. Outcomes of this work were published in a peer-reviewed journal [101]. Through this thesis it was demonstrated that predicting changes in textile geometry prior and during loading is feasible using the proposed particle-based modelling method. The particle-based modelling method relies on discrete mechanics and offers an alternative to more traditional methods based on continuum mechanics. Specifically it alleviates issues caused by large strains and management of intricate, evolving contact present in finite element simulations. The particle-based modelling method enables credible, intricate modelling of the geometry of textiles at the mesoscopic scale as well as faithful mechanical modelling under load. Changes to textile geometry and configuration due to the normal compaction pressure, stress relaxation, in-plane shear and other types of loads were successfully predicted.
The Krylov accelerated SIMPLE(R) method for flow problems in industrial furnaces
NASA Astrophysics Data System (ADS)
Vuik, C.; Saghir, A.; Boerstoel, G. P.
2000-08-01
Numerical modeling of the melting and combustion process is an important tool in gaining understanding of the physical and chemical phenomena that occur in a gas- or oil-fired glass-melting furnace. The incompressible Navier-Stokes equations are used to model the gas flow in the furnace. The discrete Navier-Stokes equations are solved by the SIMPLE(R) pressure-correction method. In these applications, many SIMPLE(R) iterations are necessary to obtain an accurate solution. In this paper, Krylov accelerated versions are proposed: GCR-SIMPLE(R). The properties of these methods are investigated for a simple two-dimensional flow. Thereafter, the efficiencies of the methods are compared for three-dimensional flows in industrial glass-melting furnaces. Copyright
44 CFR 67.6 - Basis of appeal.
Code of Federal Regulations, 2014 CFR
2014-10-01
... technically incorrect. Because scientific and technical correctness is often a matter of degree rather than...), appellants are required to demonstrate that alternative methods or applications result in more correct... due to error in application of hydrologic, hydraulic or other methods or use of inferior data in...
44 CFR 67.6 - Basis of appeal.
Code of Federal Regulations, 2012 CFR
2012-10-01
... technically incorrect. Because scientific and technical correctness is often a matter of degree rather than...), appellants are required to demonstrate that alternative methods or applications result in more correct... due to error in application of hydrologic, hydraulic or other methods or use of inferior data in...
44 CFR 67.6 - Basis of appeal.
Code of Federal Regulations, 2013 CFR
2013-10-01
... technically incorrect. Because scientific and technical correctness is often a matter of degree rather than...), appellants are required to demonstrate that alternative methods or applications result in more correct... due to error in application of hydrologic, hydraulic or other methods or use of inferior data in...
44 CFR 67.6 - Basis of appeal.
Code of Federal Regulations, 2011 CFR
2011-10-01
... technically incorrect. Because scientific and technical correctness is often a matter of degree rather than...), appellants are required to demonstrate that alternative methods or applications result in more correct... due to error in application of hydrologic, hydraulic or other methods or use of inferior data in...
Tank, J; Smith, L; Spedding, G R
2017-02-06
The flight of many birds and bats, and their robotic counterparts, occurs over a range of chord-based Reynolds numbers from 1 × 10 4 to 1.5 × 10 5 . It is precisely over this range where the aerodynamics of simple, rigid, fixed wings becomes extraordinarily sensitive to small changes in geometry and the environment, with two sets of consequences. The first is that practical lifting devices at this scale will likely not be simple, rigid, fixed wings. The second is that it becomes non-trivial to make baseline comparisons for experiment and computation, when either one can be wrong. Here we examine one ostensibly simple case of the NACA 0012 aerofoil and make careful comparison between the technical literature, and new experiments and computations. The agreement (or lack thereof) will establish one or more baseline results and some sensitivities around them. The idea is that the diagnostic procedures will help to guide comparisons and predictions in subsequent more complex cases.
Tank, J.; Smith, L.
2017-01-01
The flight of many birds and bats, and their robotic counterparts, occurs over a range of chord-based Reynolds numbers from 1 × 104 to 1.5 × 105. It is precisely over this range where the aerodynamics of simple, rigid, fixed wings becomes extraordinarily sensitive to small changes in geometry and the environment, with two sets of consequences. The first is that practical lifting devices at this scale will likely not be simple, rigid, fixed wings. The second is that it becomes non-trivial to make baseline comparisons for experiment and computation, when either one can be wrong. Here we examine one ostensibly simple case of the NACA 0012 aerofoil and make careful comparison between the technical literature, and new experiments and computations. The agreement (or lack thereof) will establish one or more baseline results and some sensitivities around them. The idea is that the diagnostic procedures will help to guide comparisons and predictions in subsequent more complex cases. PMID:28163869
Kim, Stanley E; Case, J Brad; Lewis, Daniel D; Ellison, Gary W
2015-08-01
To determine how American College of Veterinary Surgeons (ACVS) small animal surgery residency programs are teaching and assessing technical skills, and ascertain the perceived value of those methods. Internet-based survey. Residents and Diplomate supervisors of ACVS small animal residency programs. Residents and supervisors were surveyed on their experience of surgery instruction, use of different resources for teaching, type and frequency of feedback, and perceived effectiveness of their programs in imparting technical proficiency. A total of 130 residents (62%) and 119 supervisors (44%) participated. Both residents and supervisors estimated the resident was the primary surgeon for a mean of 64% of cases, although this proportion varied widely between participants. The majority of residents and supervisors considered that direct intraoperative guidance was the most effective way for residents to develop technical skills. Verbal interactions between supervisor and resident occurred frequently and were highly valued. Regular wet laboratories and access to simulation models were uncommon. Despite over 90% of all participants reporting that a sufficient level of technical aptitude would be attained, only 58% of residents were satisfied with their technical skills training. Residents relied on direct interaction with supervisors to develop technical skills. The traditional mode of instruction for veterinary residents is the apprenticeship model, which is partly driven by ACVS requirements of supervisory support. Exposure to other teaching and assessment methods was variable. The current structure of residency programs is successful in imparting technical competency as perceived by supervisors and residents. However, consideration of a more formal method of residency training with structured assessment of technical skills as in human medicine should not be dismissed. © Copyright 2015 by The American College of Veterinary Surgeons.
Spatial Information in Support of 3D Flood Damage Assessment of Buildings at Micro Level: A Review
NASA Astrophysics Data System (ADS)
Amirebrahimi, S.; Rajabifard, A.; Sabri, S.; Mendis, P.
2016-10-01
Floods, as the most common and costliest natural disaster around the globe, have adverse impacts on buildings which are considered as major contributors to the overall economic damage. With emphasis on risk management methods for reducing the risks to structures and people, estimating damage from potential flood events becomes an important task for identifying and implementing the optimal flood risk-reduction solutions. While traditional Flood Damage Assessment (FDA) methods focus on simple representation of buildings for large-scale damage assessment purposes, recent emphasis on buildings' flood resilience resulted in development of a sophisticated method that allows for a detailed and effective damage evaluation at the scale of building and its components. In pursuit of finding the suitable spatial information model to satisfy the needs of implementing such frameworks, this article explores the technical developments for an effective representation of buildings, floods and other required information within the built environment. The search begins with the Geospatial domain and investigates the state-of-the-art and relevant developments from data point of view in this area. It is further extended to other relevant disciplines in the Architecture, Engineering and Construction domain (AEC/FM) and finally, even some overlapping areas between these domains are considered and explored.
A Combined Negative and Positive Enrichment Assay for Cancer Cells Isolation and Purification.
Cheng, Boran; Wang, Shuyi; Chen, Yuanyuan; Fang, Yuan; Chen, Fangfang; Wang, Zhenmeng; Xiong, Bin
2016-02-01
Cancer cells that detach from solid tumor and circulate in the peripheral blood (CTCs) have been considered as a new "biomarker" for the detection and characterization of cancers. However, isolating and detecting cancer cells from the cancer patient peripheral blood have been technically challenging, owing to the small sub-population of CTCs (a few to hundreds per milliliter). Here we demonstrate a simple and efficient cancer cells isolation and purification method. A biocompatible and surface roughness controllable TiO2 nanofilm was deposited onto a glass slide to achieve enhanced topographic interactions with nanoscale cellular surface components, again, anti-CD45 (a leukocyte common antigen) and anti-EpCAM (epithelial cell adhesion molecule) were then coated onto the surface of the nanofilm for advance depletion of white blood cells (WBCs) and specific isolation of CTCs, respectively. Comparing to the conventional positive enrichment technology, this method exhibited excellent biocompatibility and equally high capture efficiency. Moreover, the maximum number of background cells (WBCs) was removed, and viable and functional cancer cells were isolated with high purity. Utilizing the horizontally packed TiO2 nanofilm improved pure CTC-capture through combining cell-capture-agent and cancer cell-preferred nanoscale topography, which represented a new method capable of obtaining biologically functional CTCs for subsequent molecular analysis. © The Author(s) 2014.
Stekel, Dov J.; Sarti, Donatella; Trevino, Victor; Zhang, Lihong; Salmon, Mike; Buckley, Chris D.; Stevens, Mark; Pallen, Mark J.; Penn, Charles; Falciani, Francesco
2005-01-01
A key step in the analysis of microarray data is the selection of genes that are differentially expressed. Ideally, such experiments should be properly replicated in order to infer both technical and biological variability, and the data should be subjected to rigorous hypothesis tests to identify the differentially expressed genes. However, in microarray experiments involving the analysis of very large numbers of biological samples, replication is not always practical. Therefore, there is a need for a method to select differentially expressed genes in a rational way from insufficiently replicated data. In this paper, we describe a simple method that uses bootstrapping to generate an error model from a replicated pilot study that can be used to identify differentially expressed genes in subsequent large-scale studies on the same platform, but in which there may be no replicated arrays. The method builds a stratified error model that includes array-to-array variability, feature-to-feature variability and the dependence of error on signal intensity. We apply this model to the characterization of the host response in a model of bacterial infection of human intestinal epithelial cells. We demonstrate the effectiveness of error model based microarray experiments and propose this as a general strategy for a microarray-based screening of large collections of biological samples. PMID:15800204
Sanai, Nader; Caldwell, Nolan; Englot, Dario J; Lawton, Michael T
2012-08-01
Many neurosurgeons feel competent clipping posterior communicating artery (PCoA) aneurysms and include this lesion in their practice. However, endovascular therapy removes simple aneurysms that would have been easiest to clip with the best results. What remains are aneurysms with complex anatomy and technical challenges that are not well described. A contemporary surgical series with PCoA aneurysms is reviewed to define the patients, microsurgical techniques, and outcomes in current practice. A total of 218 patients had 218 PCoA aneurysms that were treated microsurgically during an 11-year period. Complexities influencing aneurysm management included (1) large/giant size; (2) fetal posterior cerebral artery; (3) previous coiling; (4) anterior clinoidectomy; (5) adherence of the anterior choroidal artery (AChA); (6) intraoperative aneurysm rupture; (7) complex clipping; and (8) atherosclerotic calcification. Simple PCoA aneurysms were encountered in 113 patients (51.8%) and complex aneurysms in 105 (48.2%). Adherent AChA (13.8%) and intraoperative rupture (11.5%) were the most common complexities. Simple aneurysms had favorable outcomes in 86.6% of patients, whereas aneurysms with 1 or multiple complexities had favorable outcomes in 78.2% and 75.0%, respectively. Intraoperative rupture (P < .01), large/giant size (P = .04), and complex clipping (P = .05) were associated with increased neurological worsening. Because endovascular therapy alters the surgical population, neurosurgeons should recalibrate their expectations with this once straightforward aneurysm. The current mix of PCoA aneurysms requires advanced techniques including clinoidectomy, AChA microdissection, complex clipping, and facility with intraoperative rupture. Microsurgery is recommended for recurrent aneurysms after coiling, complex branches, aneurysms causing oculomotor nerve palsy, multiple aneurysms, and patients with hematomas.
An easy-to-build remote laboratory with data transfer using the Internet School Experimental System
NASA Astrophysics Data System (ADS)
Schauer, František; Lustig, František; Dvořák, Jiří; Ožvoldová, Miroslava
2008-07-01
The present state of information communication technology makes it possible to devise and run computer-based e-laboratories accessible to any user with a connection to the Internet, equipped with very simple technical means and making full use of web services. Thus, the way is open for a new strategy of physics education with strongly global features, based on experiment and experimentation. We name this strategy integrated e-learning, and remote experiments across the Internet are the foundation for this strategy. We present both pedagogical and technical reasoning for the remote experiments and outline a simple system based on a server-client approach, and on web services and Java applets. We give here an outline of the prospective remote laboratory system with data transfer using the Internet School Experimental System (ISES) as hardware and ISES WEB Control kit as software. This approach enables the simple construction of remote experiments without building any hardware and virtually no programming, using a paste and copy approach with typical prebuilt blocks such as a camera view, controls, graphs, displays, etc. We have set up and operate at present seven experiments, running round the clock, with more than 12 000 connections since 2005. The experiments are widely used in practical teaching of both university and secondary level physics. The recording of the detailed steps the experimentor takes during the measurement enables detailed study of the psychological aspects of running the experiments. The system is ready for a network of universities to start covering the basic set of physics experiments. In conclusion we summarize the results achieved and experiences of using remote experiments built on the ISES hardware system.
NASA Astrophysics Data System (ADS)
Peschmann, K. R.; Parker, D. L.; Smith, V.
1982-11-01
An abundant number of different CT scanner models has been developed in the past ten years, meeting increasing standards of performance. From the beginning they remained a comparatively expensive piece of equipment. This is due not only to their technical complexity but is also due to the difficulties involved in assessing "true" specifications (avoiding "overde-sign"). Our aim has been to provide, for Radiation Therapy Treatment Planning, a low cost CT scanner system featuring large freedom in patient positioning. We have taken advantage of the concurrent tremendously increased amount of knowledge and experience in the technical area of CT1 . By way of extensive computer simulations we gained confidence that an inexpensive C-arm simulator gantry and a simple one phase-two pulse generator in connection with a standard x-ray tube could be used, without sacrificing image quality. These components have been complemented by a commercial high precision shaft encoder, a simple and effective fan beam collimator, a high precision, high efficiency, luminescence crystal-silicon photodiode detector with 256 channels, low noise electronic preamplifier and sampling filter stages, a simplified data aquisition system furnished by Toshiba/ Analogic and an LSI 11/23 microcomputer plus data storage disk as well as various smaller interfaces linking the electrical components. The quality of CT scan pictures of phantoms,performed by the end of last year confirmed that this simple approach is working well. As a next step we intend to upgrade this system with an array processor in order to shorten recon-struction time to one minute per slice. We estimate that the system including this processor could be manufactured for a selling price of $210,000.
A study on technical efficiency of a DMU (review of literature)
NASA Astrophysics Data System (ADS)
Venkateswarlu, B.; Mahaboob, B.; Subbarami Reddy, C.; Sankar, J. Ravi
2017-11-01
In this research paper the concept of technical efficiency (due to Farell) [1] of a decision making unit (DMU) has been introduced and the measure of technical and cost efficiencies are derived. Timmer’s [2] deterministic approach to estimate the Cobb-Douglas production frontier has been proposed. The idea of extension of Timmer’s [2] method to any production frontier which is linear in parameters has been presented here. The estimation of parameters of Cobb-Douglas production frontier by linear programming approach has been discussed in this paper. Mark et al. [3] proposed a non-parametric method to assess efficiency. Nuti et al. [4] investigated the relationships among technical efficiency scores, weighted per capita cost and overall performance Gahe Zing Samuel Yank et al. [5] used Data envelopment analysis to assess technical assessment in banking sectors.
Schneider, M J; Donoghue, D J
2004-05-01
Regulatory monitoring for most antibiotic residues in edible poultry tissues is often accomplished with accurate, although expensive and technically demanding, chemical analytical techniques. The purpose of this study is to determine if a simple, inexpensive bioassay could detect fluoroquinolone (FQ) residues in chicken muscle above the FDA established tolerance (300 ppb) comparable to a liquid chromatography-fluorescencemass spectrometry(n) method. To produce incurred enrofloxacin (ENRO) tissues (where ENRO is incorporated into complex tissue matrices) for the method comparison, 40-d-old broilers (mixed sex) were orally dosed through drinking water for 3 d at the FDA-approved dose of ENRO (50 ppm). At the end of each day of the 3-d dosing period and for 3 d postdosing, birds were sacrificed and breast and thigh muscle collected and analyzed. Both methods were able to detect ENRO at and below the tolerance level in the muscle, with limits of detection of 26 ppb (bioassay), 0.1 ppb for ENRO, and 0.5 ppb for the ENRO metabolite, ciprofloxacin (liquid chromatography-fluorescence-mass spectrometry(n)). All samples that had violative levels of antibiotic were detected by the bioassay. These results support the use of this bioassay as a screening method for examining large numbers of samples for regulatory monitoring. Positive samples should then be examined by a more extensive method, such as liquid chromatography-fluorescence-mass spectrometry(n), to provide confirmation of the analyte.
Spatial Normalization of Reverse Phase Protein Array Data
Kaushik, Poorvi; Molinelli, Evan J.; Miller, Martin L.; Wang, Weiqing; Korkut, Anil; Liu, Wenbin; Ju, Zhenlin; Lu, Yiling; Mills, Gordon; Sander, Chris
2014-01-01
Reverse phase protein arrays (RPPA) are an efficient, high-throughput, cost-effective method for the quantification of specific proteins in complex biological samples. The quality of RPPA data may be affected by various sources of error. One of these, spatial variation, is caused by uneven exposure of different parts of an RPPA slide to the reagents used in protein detection. We present a method for the determination and correction of systematic spatial variation in RPPA slides using positive control spots printed on each slide. The method uses a simple bi-linear interpolation technique to obtain a surface representing the spatial variation occurring across the dimensions of a slide. This surface is used to calculate correction factors that can normalize the relative protein concentrations of the samples on each slide. The adoption of the method results in increased agreement between technical and biological replicates of various tumor and cell-line derived samples. Further, in data from a study of the melanoma cell-line SKMEL-133, several slides that had previously been rejected because they had a coefficient of variation (CV) greater than 15%, are rescued by reduction of CV below this threshold in each case. The method is implemented in the R statistical programing language. It is compatible with MicroVigene and SuperCurve, packages commonly used in RPPA data analysis. The method is made available, along with suggestions for implementation, at http://bitbucket.org/rppa_preprocess/rppa_preprocess/src. PMID:25501559
40 CFR Appendix D to Part 136 - Precision and Recovery Statements for Methods for Measuring Metals
Code of Federal Regulations, 2010 CFR
2010-07-01
... Spectroscopy (Direction Aspiration) and Colorimetry”, National Technical Information Service, 5285 Port Royal... Spectroscopy (Direct Aspiration) and Colorimetry”, National Technical Information Service, 5285 Port Royal Road... Absorption Spectroscopy (Direct Aspiration) and Colorimetry”, National Technical Information Service, 5285...
32 CFR 701.38 - Technical data.
Code of Federal Regulations, 2013 CFR
2013-07-01
... OFFICIAL RECORDS AVAILABILITY OF DEPARTMENT OF THE NAVY RECORDS AND PUBLICATION OF DEPARTMENT OF THE NAVY DOCUMENTS AFFECTING THE PUBLIC FOIA Definitions and Terms § 701.38 Technical data. Recorded information, regardless of form or method of the recording, of a scientific or technical nature (including computer...
32 CFR 701.38 - Technical data.
Code of Federal Regulations, 2012 CFR
2012-07-01
... OFFICIAL RECORDS AVAILABILITY OF DEPARTMENT OF THE NAVY RECORDS AND PUBLICATION OF DEPARTMENT OF THE NAVY DOCUMENTS AFFECTING THE PUBLIC FOIA Definitions and Terms § 701.38 Technical data. Recorded information, regardless of form or method of the recording, of a scientific or technical nature (including computer...
32 CFR 701.38 - Technical data.
Code of Federal Regulations, 2014 CFR
2014-07-01
... OFFICIAL RECORDS AVAILABILITY OF DEPARTMENT OF THE NAVY RECORDS AND PUBLICATION OF DEPARTMENT OF THE NAVY DOCUMENTS AFFECTING THE PUBLIC FOIA Definitions and Terms § 701.38 Technical data. Recorded information, regardless of form or method of the recording, of a scientific or technical nature (including computer...
Assessing Non-Technical Site Suitability Criteria for Stormwater Capture, Treatment and Recharge
NASA Astrophysics Data System (ADS)
Eisenstein, W.
2016-12-01
This presentation will describe a new method for assessing non-technical site suitability criteria for the siting of stormwater capture, treatment and recharge (or stormwater CTR) facilities in Sonoma County, California, USA. "Non-technical site suitability criteria" include issues such as community acceptance, aesthetics, nuisances and hazards, and compatibility with neighboring land uses, and are distinguished from "technical criteria" such as hydrology and soil characteristics that are the traditional subject of suitability analyses. Non-technical criteria are rarely, if ever, considered in formal siting suitability studies conducted by agencies and municipalities, yet can be fatal to the prospects of a given project's construction if not identified and mitigated. The researchers developed a new method for identifying and spatially characterizing relevant non-technical criteria through interviews and questionnaires with community stakeholders, and introducing those criteria into a spatial multi-criteria decision analysis framework that assesses site suitabilty across a study watershed (the Upper Petaluma River watershed in Sonoma County).
Evaluating the effectiveness of case method instruction in technical communication
NASA Technical Reports Server (NTRS)
Feinberg, S. G.
1981-01-01
The effectiveness of the case method as an instructional technique in improving technical writing was evaluated. The development of a self-report instrument that attempts to measure changes in attitude toward technical communication and the presentation results change are the purpose of this paper. Standards for developing a case set forth by Goldstein and Couture, were used to design an evaluation instrument to measure the effect instruction on student attitude toward technical communication. This self-report instrument is based on model developed and tested by Daly and Miller who studied writer attitude and apprehension toward writing. It was the most important objective of any evaluation is to provide information for improving the program.
ERIC Educational Resources Information Center
McCullough, Robert A.; And Others
This report presents the results of a review and evaluation of the Langley Research Center's scientific and technical information program, which examined technical reports from various institutions and organizations to determine the organization of reports, the language used to convey information, and the methods used to present information.…
Developing a scientific procedure for community based hazard mapping and risk mitigation
NASA Astrophysics Data System (ADS)
Verrier, M.
2011-12-01
As an international exchange student from the Geological Sciences Department at San Diego State University (SDSU), I joined the KKN-PPM program at Universitas Gadjah Mada (UGM), Yogyakarta, Indonesia, in July 2011 for 12 days (July 4th to July 16th) of its two month duration (July 4th to August 25th). The KKN-PPM group I was attached was designated 154 and was focused in Plosorejo Village, Karanganyar, Kerjo, Central Java, Indonesia. The mission of KKN-PPM 154 was to survey Plosorejo village for existing landslides, to generate a simple hazard susceptibility map that can be understood by local villagers, and then to begin dissemination of that map into the community. To generate our susceptibility map we first conducted a geological survey of the existing landslides in the field study area, with a focus on determining landslide triggers and gauging areas for susceptibility for future landslides. The methods for gauging susceptibility included lithological observation, the presence of linear cracking, visible loss of structural integrity in structures such as villager homes, as well as collaboration with local residents and with the local rescue and response team. There were three color distinctions used in representing susceptibility which were green, where there is no immediate danger of landslide damage; orange, where transportation routes are at risk of being disrupted by landslides; and red, where imminent landslide potential puts a home in direct danger. The landslide inventory and susceptibility data was compiled into digital mediums such as CorelDraw, ArcGIS and Google Earth. Once a technical map was generated, we presented it to the village leadership for confirmation and modification based on their experience. Finally, we began to use the technical susceptibility map to draft evacuation routes and meeting points in the event of landslides, as well as simple susceptibility maps that can be understood and utilized by local villagers. Landslide mitigation projects that are being conducted alongside the community hazard map include marking evacuation routes with painted bamboo signs, creating a meaningful landslide awareness mural, and installing simple early warning systems that detect land movement and alert residents that evacuation routes should be used. KKN-PPM is scheduled to continue until August 25th, 2011. In the future, research will be done into using the model for community based hazard mapping outlined here in the Geological Sciences Department at SDSU to increase georisk awareness and improve mitigation of landslides in local areas of need such as Tijuana, Mexico.
Technical Efficiency and Organ Transplant Performance: A Mixed-Method Approach
de-Pablos-Heredero, Carmen; Fernández-Renedo, Carlos; Medina-Merodio, Jose-Amelio
2015-01-01
Mixed methods research is interesting to understand complex processes. Organ transplants are complex processes in need of improved final performance in times of budgetary restrictions. As the main objective a mixed method approach is used in this article to quantify the technical efficiency and the excellence achieved in organ transplant systems and to prove the influence of organizational structures and internal processes in the observed technical efficiency. The results show that it is possible to implement mechanisms for the measurement of the different components by making use of quantitative and qualitative methodologies. The analysis show a positive relationship between the levels related to the Baldrige indicators and the observed technical efficiency in the donation and transplant units of the 11 analyzed hospitals. Therefore it is possible to conclude that high levels in the Baldrige indexes are a necessary condition to reach an increased level of the service offered. PMID:25950653
On modeling human reliability in space flights - Redundancy and recovery operations
NASA Astrophysics Data System (ADS)
Aarset, M.; Wright, J. F.
The reliability of humans is of paramount importance to the safety of space flight systems. This paper describes why 'back-up' operators might not be the best solution, and in some cases, might even degrade system reliability. The problem associated with human redundancy calls for special treatment in reliability analyses. The concept of Standby Redundancy is adopted, and psychological and mathematical models are introduced to improve the way such problems can be estimated and handled. In the past, human reliability has practically been neglected in most reliability analyses, and, when included, the humans have been modeled as a component and treated numerically the way technical components are. This approach is not wrong in itself, but it may lead to systematic errors if too simple analogies from the technical domain are used in the modeling of human behavior. In this paper redundancy in a man-machine system will be addressed. It will be shown how simplification from the technical domain, when applied to human components of a system, may give non-conservative estimates of system reliability.
NASA Astrophysics Data System (ADS)
Pang, Linyong; Hu, Peter; Satake, Masaki; Tolani, Vikram; Peng, Danping; Li, Ying; Chen, Dongxue
2011-11-01
According to the ITRS roadmap, mask defects are among the top technical challenges to introduce extreme ultraviolet (EUV) lithography into production. Making a multilayer defect-free extreme ultraviolet (EUV) blank is not possible today, and is unlikely to happen in the next few years. This means that EUV must work with multilayer defects present on the mask. The method proposed by Luminescent is to compensate effects of multilayer defects on images by modifying the absorber patterns. The effect of a multilayer defect is to distort the images of adjacent absorber patterns. Although the defect cannot be repaired, the images may be restored to their desired targets by changing the absorber patterns. This method was first introduced in our paper at BACUS 2010, which described a simple pixel-based compensation algorithm using a fast multilayer model. The fast model made it possible to complete the compensation calculations in seconds, instead of days or weeks required for rigorous Finite Domain Time Difference (FDTD) simulations. Our SPIE 2011 paper introduced an advanced compensation algorithm using the Level Set Method for 2D absorber patterns. In this paper the method is extended to consider process window, and allow repair tool constraints, such as permitting etching but not deposition. The multilayer defect growth model is also enhanced so that the multilayer defect can be "inverted", or recovered from the top layer profile using a calibrated model.
Felbaum, Daniel R; Anaizi, Amjad; Mason, Robert B; Jean, Walter C; Voyadzis, Jean M
2016-01-01
Introduction: Suboccipital craniotomy is a workhorse neurosurgical operation for approaching the posterior fossa but carries a high risk of pseudomeningocele and cerebrospinal fluid (CSF) leak. We describe our experience with a simple T-shaped fascial opening that preserves the occipital myofascial cuff as compared to traditional methods to reduce this risk. Methods: A single institution, retrospective review of prospectively collected database was performed of patients that underwent a suboccipital craniectomy or craniotomy. Patient data was reviewed for craniotomy or craniectomy, dural graft, and/or sealant use as well as CSF complications. A pseudomeningocele was defined as a subcutaneous collection of cerebrospinal fluid palpable clinically and confirmed on imaging. A CSF leak was defined as a CSF-cutaneous fistula manifested by CSF leaking through the wound. All patients underwent regular postoperative visits of two weeks, one month, and three months. Results: Our retrospective review identified 33 patients matching the inclusion criteria. Overall, our cohort had a 21% (7/33) rate of clinical and radiographic pseudomeningocele formation with 9% (3/33) requiring surgical revision or a separate procedure. The rate of clinical and radiographic pseudomeningocele formation in the myofascial cuff preservation technique was less than standard techniques (12% and 31%, respectively). Revision or further surgical procedures were also reduced in the myofascial cuff preservation technique vs. the standard technique (6% vs 13%). Conclusions: Preservation of the myofascial cuff during posterior fossa surgery is a simple and adoptable technique that reduces the rate of pseudomeningocele formation and CSF leak as compared with standard techniques. PMID:28133584
Burbelo, Peter D; Goldman, Radoslav; Mattson, Thomas L
2005-08-18
Assays detecting human antigen-specific antibodies are medically useful. However, the usefulness of existing simple immunoassay formats is limited by technical considerations such as sera antibodies to contaminants in insufficiently pure antigen, a problem likely exacerbated when antigen panels are screened to obtain clinically useful data. We developed a novel and simple immunoprecipitation technology for identifying clinical sera containing antigen-specific antibodies and for generating quantitative antibody response profiles. This method is based on fusing protein antigens to an enzyme reporter, Renilla luciferase (Ruc), and expressing these fusions in mammalian cells, where mammalian-specific post-translational modifications can be added. After mixing crude extracts, sera and protein A/G beads together and incubating, during which the Ruc-antigen fusion become immobilized on the A/G beads, antigen-specific antibody is quantitated by washing the beads and adding coelenterazine substrate and measuring light production. We have characterized this technology with sera from patients having three different types of cancers. We show that 20-85% of these sera contain significant titers of antibodies against at least one of five frequently mutated and/or overexpressed tumor-associated proteins. Five of six colon cancer sera tested gave responses that were statistically significantly greater than the average plus three standard deviations of 10 control sera. The results of competition experiments, preincubating positive sera with unmodified E. coli-produced antigens, varied dramatically. This technology has several advantages over current quantitative immunoassays including its relative simplicity, its avoidance of problems associated with E. coli-produced antigens and its use of antigens that can carry mammalian or disease-specific post-translational modifications. This assay should be generally useful for analyzing sera for antibodies recognizing any protein or its post-translational modifications.
Burbelo, Peter D; Goldman, Radoslav; Mattson, Thomas L
2005-01-01
Background Assays detecting human antigen-specific antibodies are medically useful. However, the usefulness of existing simple immunoassay formats is limited by technical considerations such as sera antibodies to contaminants in insufficiently pure antigen, a problem likely exacerbated when antigen panels are screened to obtain clinically useful data. Results We developed a novel and simple immunoprecipitation technology for identifying clinical sera containing antigen-specific antibodies and for generating quantitative antibody response profiles. This method is based on fusing protein antigens to an enzyme reporter, Renilla luciferase (Ruc), and expressing these fusions in mammalian cells, where mammalian-specific post-translational modifications can be added. After mixing crude extracts, sera and protein A/G beads together and incubating, during which the Ruc-antigen fusion become immobilized on the A/G beads, antigen-specific antibody is quantitated by washing the beads and adding coelenterazine substrate and measuring light production. We have characterized this technology with sera from patients having three different types of cancers. We show that 20–85% of these sera contain significant titers of antibodies against at least one of five frequently mutated and/or overexpressed tumor-associated proteins. Five of six colon cancer sera tested gave responses that were statistically significantly greater than the average plus three standard deviations of 10 control sera. The results of competition experiments, preincubating positive sera with unmodified E. coli-produced antigens, varied dramatically. Conclusion This technology has several advantages over current quantitative immunoassays including its relative simplicity, its avoidance of problems associated with E. coli-produced antigens and its use of antigens that can carry mammalian or disease-specific post-translational modifications. This assay should be generally useful for analyzing sera for antibodies recognizing any protein or its post-translational modifications. PMID:16109166
Shinde, N M; Xia, Qi Xun; Yun, Je Moon; Singh, Saurabh; Mane, Rajaram S; Kim, Kwang-Ho
2017-05-23
The present study involves the synthesis of a bismuth oxide (Bi 2 O 3 ) electrode consisting of an arranged nano-platelets for evolving a flower-type surface appearance on nickel-foam (Bi 2 O 3 -Ni-F) by a simple, inexpensive, binder-free and one-step chemical bath deposition (CBD) method, popularly known as a wet chemical method. The as-prepared Bi 2 O 3 on Ni-foam, as an electrode material, demonstrates 557 F g -1 specific capacitance (SC, at 1 mA cm -2 ), of which 85% is retained even after 2000 cycles. With specific power density of 500 kW kg -1 , the Bi 2 O 3 -Ni-F electrode documents a specific energy density of 80 Wh kg -1 . Furthermore, a portable asymmetric supercapacitor device, i.e. a pencil-type cell consisting of Bi 2 O 3 -Ni-F as an anode and graphite as a cathode in 6 M KOH aqueous electrolyte solution, confirms 11 Wh kg -1 and 720 kW kg -1 specific energy and specific power densities, respectively. An easy and a simple synthesis approach for manufacturing a portable laboratory scale pencil-type supercapacitor device is a major outcome of this study, which can also be applied for ternary and quaternary metal oxides for recording an enhanced performance. In addition, we presented a demonstration of lighting a light emitting diode (LED) using a home-made pencil-type supercapacitor device which, finally, has confirmed the scaling and technical potentiality of Bi 2 O 3 -Ni-F in energy storage devices.
The International Ultraviolet Explorer: Case study in spacecraft design
NASA Technical Reports Server (NTRS)
Freeman, H. R.; Longanecker, G. W.
1979-01-01
The International Ultraviolet Explorer (IUE) is a geosynchronous scientific satellite that was conceived as an international space observatory capable of measuring UV spectra of faint celestial bodies. Simple operational procedures allow the astronomers to joystick the spaceborne telescope about the sky, using familiar ground-based observatory techniques. The present paper deals with the IUE project objectives, the technical problems, constraints, trade-offs, and the problem solving techniques used in the IUE program.
ERIC Educational Resources Information Center
Winkel, Annette; Schwarz, Stephan
By carefully considering the special characteristics of two small African scientific and technical (S&T) information systems for research and development (R&D), this report defines a simple and straightforward model which can be easily implemented in similar situations with a minimum of external support. The model is designed to build up a…
BACKSCAT Lidar Simulation Version 3.0: Technical Documentation and Users Guide
1992-12-03
Raman Cross Section of Some Simple Gases, J. Opt. Soc. Am., 63:73. 20 Penny, C.M., St. Peters, R.L., and Lapp, M., (1974) Absolute Rotational Raman...of the molecule, and the remaining columns list the relative normalized cross sections for the respective excitation wavelength. The absolute Raman...cross section is obtained by simply multiplying the relative normalized cross section for a molecular species of interest by the absolute cross section
Signal transmission competing with noise in model excitable brains
NASA Astrophysics Data System (ADS)
Marro, J.; Mejias, J. F.; Pinamonti, G.; Torres, J. J.
2013-01-01
This is a short review of recent studies in our group on how weak signals may efficiently propagate in a system with noise-induced excitation-inhibition competition which adapts to the activity at short-time scales and thus induces excitable conditions. Our numerical results on simple mathematical models should hold for many complex networks in nature, including some brain cortical areas. In particular, they serve us here to interpret available psycho-technical data.
2006-03-01
converters from GIL and many other formats. Other hilites: command line argument parsing, a simple set of routines for de- veloping Xwindows graphical...Ramakrishna Nemani, James E. Vogelmann, V. Ruth Hobson, Benjamin Tuttle, Jeff Safran, Ingrid Nelson. (2001). “Development Sprawl Impacts on the... Sale Prices as a Basis for Farm Land Appraisal,” Technical Bulletin, University of Minnesota. Hosmer, D.W., and S. Lemeshow. (1989). Applied
15 CFR 1180.1 - Purpose and scope.
Code of Federal Regulations, 2011 CFR
2011-01-01
...) TECHNOLOGY ADMINISTRATION, DEPARTMENT OF COMMERCE TRANSFER BY FEDERAL AGENCIES OF SCIENTIFIC, TECHNICAL AND... purpose of this regulation is to facilitate public access to the vast amount of scientific, technical and... variety of methods for federal agencies to adopt to ensure the timely transfer to the National Technical...
15 CFR 1180.1 - Purpose and scope.
Code of Federal Regulations, 2013 CFR
2013-01-01
...) TECHNOLOGY ADMINISTRATION, DEPARTMENT OF COMMERCE TRANSFER BY FEDERAL AGENCIES OF SCIENTIFIC, TECHNICAL AND... purpose of this regulation is to facilitate public access to the vast amount of scientific, technical and... variety of methods for federal agencies to adopt to ensure the timely transfer to the National Technical...
15 CFR 1180.1 - Purpose and scope.
Code of Federal Regulations, 2012 CFR
2012-01-01
...) TECHNOLOGY ADMINISTRATION, DEPARTMENT OF COMMERCE TRANSFER BY FEDERAL AGENCIES OF SCIENTIFIC, TECHNICAL AND... purpose of this regulation is to facilitate public access to the vast amount of scientific, technical and... variety of methods for federal agencies to adopt to ensure the timely transfer to the National Technical...
15 CFR 1180.1 - Purpose and scope.
Code of Federal Regulations, 2010 CFR
2010-01-01
...) TECHNOLOGY ADMINISTRATION, DEPARTMENT OF COMMERCE TRANSFER BY FEDERAL AGENCIES OF SCIENTIFIC, TECHNICAL AND... purpose of this regulation is to facilitate public access to the vast amount of scientific, technical and... variety of methods for federal agencies to adopt to ensure the timely transfer to the National Technical...
Storyboarding: A Concrete Way to Generate Effective Visuals.
ERIC Educational Resources Information Center
Larkin, Greg
1996-01-01
Advances the idea that storyboarding, long associated with scriptwriting, advertising, and more recently with technical manuals, can be successfully applied to an even broader variety of technical documents. Applies storyboarding techniques to designing technical proposals to suggest methods of incorporating more visuals into documents, as well as…
Hayashi, Shogo; Naito, Munekazu; Kawata, Shinichi; Qu, Ning; Hatayama, Naoyuki; Hirai, Shuichi; Itoh, Masahiro
2016-01-01
Traditionally, surgical training meant on-the-job training with live patients in an operating room. However, due to advancing surgical techniques, such as minimally invasive surgery, and increasing safety demands during procedures, human cadavers have been used for surgical training. When considering the use of human cadavers for surgical training, one of the most important factors is their preservation. In this review, we summarize four preservation methods: fresh-frozen cadaver, formalin, Thiel's, and saturated salt solution methods. Fresh-frozen cadaver is currently the model that is closest to reality, but it also presents myriad problems, including the requirement of freezers for storage, limited work time because of rapid putrefaction, and risk of infection. Formalin is still used ubiquitously due to its low cost and wide availability, but it is not ideal because formaldehyde has an adverse health effect and formalin-embalmed cadavers do not exhibit many of the qualities of living organs. Thiel's method results in soft and flexible cadavers with almost natural colors, and Thiel-embalmed cadavers have been appraised widely in various medical disciplines. However, Thiel's method is relatively expensive and technically complicated. In addition, Thiel-embalmed cadavers have a limited dissection time. The saturated salt solution method is simple, carries a low risk of infection, and is relatively low cost. Although more research is needed, this method seems to be sufficiently useful for surgical training and has noteworthy features that expand the capability of clinical training. The saturated salt solution method will contribute to a wider use of cadavers for surgical training.
Simple-MSSM: a simple and efficient method for simultaneous multi-site saturation mutagenesis.
Cheng, Feng; Xu, Jian-Miao; Xiang, Chao; Liu, Zhi-Qiang; Zhao, Li-Qing; Zheng, Yu-Guo
2017-04-01
To develop a practically simple and robust multi-site saturation mutagenesis (MSSM) method that enables simultaneously recombination of amino acid positions for focused mutant library generation. A general restriction enzyme-free and ligase-free MSSM method (Simple-MSSM) based on prolonged overlap extension PCR (POE-PCR) and Simple Cloning techniques. As a proof of principle of Simple-MSSM, the gene of eGFP (enhanced green fluorescent protein) was used as a template gene for simultaneous mutagenesis of five codons. Forty-eight randomly selected clones were sequenced. Sequencing revealed that all the 48 clones showed at least one mutant codon (mutation efficiency = 100%), and 46 out of the 48 clones had mutations at all the five codons. The obtained diversities at these five codons are 27, 24, 26, 26 and 22, respectively, which correspond to 84, 75, 81, 81, 69% of the theoretical diversity offered by NNK-degeneration (32 codons; NNK, K = T or G). The enzyme-free Simple-MSSM method can simultaneously and efficiently saturate five codons within one day, and therefore avoid missing interactions between residues in interacting amino acid networks.
Irwin, A; Weidmann, A E
2015-01-01
Non-technical skills refer to the social and cognitive factors that may influence efficient and safe job performance. Non-technical skills are an important element of patient safety in a variety of health care disciplines, including surgery, anesthesia and nursing. However, the use of non-technical skills in pharmacy practice has not yet been fully assessed. To examine attitudes toward, and use of, non-technical skills by pharmacy personnel. A mixed methods approach was used: An attitude survey explored pharmacy personnel attitudes towards non-technical skills and inter-professional collaboration, with community and hospital pharmacy staff (n = 62). Qualitative interviews were then conducted using the critical incident technique, with community pharmacists (n = 11). The survey results demonstrated differences in the opinions of community and hospital pharmacists on three non-technical skill constructs: team structure, mutual support, and situation monitoring, with community pharmacists reporting significantly more positive attitudes about all three constructs. Both groups reported low levels of collaboration with primary care physicians. The interviews identified five non-technical skills as key elements of successful pharmacist performance from the interview transcripts: teamwork; leadership; task management; situation awareness; decision-making. The survey and interviews identified the non-technical skills that are important to pharmacists. This represents the first step towards the development of a behavioral rating system for training purposes that could potentially improve the non-technical skills of pharmacists and enhance patient safety. Copyright © 2015 Elsevier Inc. All rights reserved.
Pestel, Sabine; Jungermann, Kurt; Schieferdecker, Henrike L
2005-01-01
In contrast to conventionally used immunoassays, thin layer chromatography (TLC)--by prelabeling of cells with radioactive arachidonic acid (AA)--allows to differentiate between cellularly built and added prostanoids and thus to investigate feedback effects of prostanoids on their own release. PGD2, TXB2 and PGE2 released from zymosan-stimulated Kupffer cells were separated with distinct RF-values, corresponding to those of the pure substances. Quantification of PGD2 and PGE2 gave comparable results with TLC and immunoassays, but measurement in the presence of added prostanoids was only possible with TLC. Moreover TLC was superior to immunoassays in having a longer linear range while being comparably sensitive. Cellularly built TXB2 in its radioactively labeled form was not detectable by TLC. Inhibition of TXB2 release by externally added AA or technical artifacts were excluded, suggesting that the cellular AA-pools used for prostaglandin and thromboxane synthesis differ in their accessibility for added AA. Thus, TLC is a simple, sensitive and precise method for the quantification of cellularly built prostaglandins but not of thromboxane even in the presence of added prostanoids.
2013-01-01
Background Traditional Lot Quality Assurance Sampling (LQAS) designs assume observations are collected using simple random sampling. Alternatively, randomly sampling clusters of observations and then individuals within clusters reduces costs but decreases the precision of the classifications. In this paper, we develop a general framework for designing the cluster(C)-LQAS system and illustrate the method with the design of data quality assessments for the community health worker program in Rwanda. Results To determine sample size and decision rules for C-LQAS, we use the beta-binomial distribution to account for inflated risk of errors introduced by sampling clusters at the first stage. We present general theory and code for sample size calculations. The C-LQAS sample sizes provided in this paper constrain misclassification risks below user-specified limits. Multiple C-LQAS systems meet the specified risk requirements, but numerous considerations, including per-cluster versus per-individual sampling costs, help identify optimal systems for distinct applications. Conclusions We show the utility of C-LQAS for data quality assessments, but the method generalizes to numerous applications. This paper provides the necessary technical detail and supplemental code to support the design of C-LQAS for specific programs. PMID:24160725
Hedt-Gauthier, Bethany L; Mitsunaga, Tisha; Hund, Lauren; Olives, Casey; Pagano, Marcello
2013-10-26
Traditional Lot Quality Assurance Sampling (LQAS) designs assume observations are collected using simple random sampling. Alternatively, randomly sampling clusters of observations and then individuals within clusters reduces costs but decreases the precision of the classifications. In this paper, we develop a general framework for designing the cluster(C)-LQAS system and illustrate the method with the design of data quality assessments for the community health worker program in Rwanda. To determine sample size and decision rules for C-LQAS, we use the beta-binomial distribution to account for inflated risk of errors introduced by sampling clusters at the first stage. We present general theory and code for sample size calculations.The C-LQAS sample sizes provided in this paper constrain misclassification risks below user-specified limits. Multiple C-LQAS systems meet the specified risk requirements, but numerous considerations, including per-cluster versus per-individual sampling costs, help identify optimal systems for distinct applications. We show the utility of C-LQAS for data quality assessments, but the method generalizes to numerous applications. This paper provides the necessary technical detail and supplemental code to support the design of C-LQAS for specific programs.
Kubo, S; Nakata, H; Sugauchi, Y; Yokota, N; Yoshimine, T
2000-05-01
The preoperative localization of superficial intracranial lesions is often necessary for accurate burr hole placement or craniotomy siting. It is not always easy, however, to localize the lesions over the scalp working only from computed tomographic images. We developed a simple method for such localization using a laser pointer during the preoperative computed tomographic examination. The angle of incidence, extending from a point on the scalp to the center of the computed tomographic image, is measured by the software included with the scanner. In the gantry, at the same angle as on the image, a laser is beamed from a handmade projector onto the patient's scalp toward the center of the gantry. The point illuminated on the patient's head corresponds to that on the image. The device and the method are described in detail herein. We applied this technique to mark the area for the craniotomy before surgery in five patients with superficial brain tumors. At the time of surgery, it was confirmed that the tumors were circumscribed precisely. The technique is easy to perform and useful in the preoperative planning for a craniotomy. In addition, the device is easily constructed and inexpensive.
Rotating Cryocooler for Superconducting Motor
NASA Astrophysics Data System (ADS)
Ko, Junseok; Jeong, Sangkwon; Kim, Hongseong; Jung, Jeheon; Choi, Jaeyoung; In, Sehwan; Sohn, Myunghwan; Kwon, Young-Kil
2006-04-01
A single-stage coaxial pulse tube refrigerator has been designed for HTS (High Temperature Superconductor) motor application. This paper discusses a practical realization of an advanced cooling method for superconducting rotor, on-board cryocooler. When a cryocooler is considered to be mounted on the superconducting rotor, the following two factors must be satisfied for practical application. First, the on-board cryocooler should not disturb the high-speed revolution of the rotor. Second, at the same time, the high-speed revolution of the rotor should not deteriorate the cooling performance of the cryocooler. These mutual technical demands restrict the type of cryocooler suitable for high-speed rotating environment. We select a Stirling-type coaxial pulse tube cryocooler and incorporate it on the 1800-rpm superconducting motor mock-up. The pulse tube cryocooler is designed with an adiabatic model and a various loss mechanism analysis. The no-load temperature is approximately 100 K with less than 150 W electric input power. The axisymmetric configuration of the fabricated cryocooler does not produce any undesirable effect at high-speed rotation. Even if the thermal performance of the rotating pulse tube cryocooler is not satisfactory, the feasibility of simple on-board cooling method for superconducting rotor is confirmed in this paper.
Design enhancement tools in MSC/NASTRAN
NASA Technical Reports Server (NTRS)
Wallerstein, D. V.
1984-01-01
Design sensitivity is the calculation of derivatives of constraint functions with respect to design variables. While a knowledge of these derivatives is useful in its own right, the derivatives are required in many efficient optimization methods. Constraint derivatives are also required in some reanalysis methods. It is shown where the sensitivity coefficients fit into the scheme of a basic organization of an optimization procedure. The analyzer is to be taken as MSC/NASTRAN. The terminator program monitors the termination criteria and ends the optimization procedure when the criteria are satisfied. This program can reside in several plances: in the optimizer itself, in a user written code, or as part of the MSC/EOS (Engineering Operating System) MSC/EOS currently under development. Since several excellent optimization codes exist and since they require such very specialized technical knowledge, the optimizer under the new MSC/EOS is considered to be selected and supplied by the user to meet his specific needs and preferences. The one exception to this is a fully stressed design (FSD) based on simple scaling. The gradients are currently supplied by various design sensitivity options now existing in MSC/NASTRAN's design sensitivity analysis (DSA).
Effects of fixture rotation on coating uniformity for high-performance optical filter fabrication
NASA Astrophysics Data System (ADS)
Rubin, Binyamin; George, Jason; Singhal, Riju
2018-04-01
Coating uniformity is critical in fabricating high-performance optical filters by various vacuum deposition methods. Simple and planetary rotation systems with shadow masks are used to achieve the required uniformity [J. B. Oliver and D. Talbot, Appl. Optics 45, 13, 3097 (2006); O. Lyngnes, K. Kraus, A. Ode and T. Erguder, in `Method for Designing Coating Thickness Uniformity Shadow Masks for Deposition Systems with a Planetary Fixture', 2014 Technical Conference Proceedings, Optical Coatings, August 13, 2014, DOI: 10.14332/svc14.proc.1817.]. In this work, we discuss the effect of rotation pattern and speed on thickness uniformity in an ion beam sputter deposition system. Numerical modeling is used to determine statistical distribution of random thickness errors in coating layers. The relationship between thickness tolerance and production yield are simulated theoretically and demonstrated experimentally. Production yields for different optical filters produced in an ion beam deposition system with planetary rotation are presented. Single-wavelength and broadband optical monitoring systems were used for endpoint monitoring during filter deposition. Limitations of thickness tolerances that can be achieved in systems with planetary rotation are shown. Paths for improving production yield in an ion beam deposition system are described.
Khramov, E N; Osin, N S; Pomelova, V G; Vikha, I V; Bychenkova, T A; Smirnova, V G; Grakina, G I; Kas'ianova, T A
1999-01-01
The comprehensive development of dot-EIA made at the State Research Institute of Biological Instrument-Making Industry has provided devices KIMF-02 and KIMF-03), a base of chemical reagents, immunoassays, test systems for detection of a wide range of causative agents of viral and bacterial infections, that of serodiagnosis of their related diseases. The KIMF-02 kit has undergone engineering and medical tests and recommended for the Ministry of Health of the Russian Federation to produce them in stock. The kit includes all required for analysis even in an ill-equipped laboratory, a set of attached agents ensures a valid visual recording of results. The developed procedures and test systems allow the immunoassay to be as sensitive as TIFA; however, they are laborious and much simpler in design. The simple and rapid procedures of dot-EIA are recommended for incorporation into the a package of laboratory methods for verification of the accumulation of virus-specific antigens in various biological substrata, environmental samples, for control of the activity of antigens and antibodies used in serological tests, for detection of specific antigens in the clinical samples, and for serodiagnosis of infections.
ERIC Educational Resources Information Center
Wonacott, Michael E.
Both face-to-face and distance learning methods are currently being used in adult education and career and technical education. In theory, the advantages of face-to-face and distance learning methods complement each other. In practice, however, both face-to-face and information and communications technology (ICT)-based distance programs often rely…
ERIC Educational Resources Information Center
Richardson, Alison Mead
2009-01-01
This paper reports on a longitudinal, ethnomethodological case study of the development towards flexible delivery of the Botswana Technical Education Programme (BTEP), offered by Francistown College of Technical & Vocational Education (FCTVE). Data collection methods included documentary analysis, naturalistic participant observation, and…
A "Virtual Fieldtrip": Service Learning in Distance Education Technical Writing Courses
ERIC Educational Resources Information Center
Soria, Krista M.; Weiner, Brad
2013-01-01
This mixed-methods experimental study examined the effect of service learning in a distance education technical writing course. Quantitative analysis of data found evidence for a positive relationship between participation in service learning and technical writing learning outcomes. Additionally, qualitative analysis suggests that service learning…
Influence of the Mesh Geometry Evolution on Gearbox Dynamics during Its Maintenance
NASA Astrophysics Data System (ADS)
Dąbrowski, Z.; Dziurdź, J.; Klekot, G.
2017-12-01
Toothed gears constitute the necessary elements of power transmission systems. They are applied as stationary devices in drive systems of road vehicles, ships and crafts as well as airplanes and helicopters. One of the problems related to the toothed gears usage is the determination of their technical state or its evolutions. Assuming that the gear slippage velocity is attributed to vibrations and noises generated by cooperating toothed wheels, the application of a simple cooperation model of rolled wheels of skew teeth is proposed for the analysis of the mesh evolution influence on the gear dynamics. In addition, an example of utilising an ordinary coherence function for investigating evolutionary mesh changes related to the effects impossible to be described by means of the simple kinematic model is presented.
Sadigh, Parviz Lionel; Chang, Li-Ren; Feng, Kuan-Ming; Jeng, Seng-Feng
2014-09-01
Bioabsorbable plates developed for use in the facial skeleton have become an integral part of the craniomaxillofacial surgeon's reconstructive armamentarium. They avoid the problems associated with the retention of metal plates and can be easily contoured when heated in a thermobath. The technical process of molding and securing these devices, often through small access incisions, to achieve rigid fixation of facial fractures can be difficult. In this article, we describe a simple, novel technique that we have developed, using hot water suction irrigation, to achieve in situ molding of resorbable plates during facial fracture fixation. We used this technique to fix 123 facial fractures in 110 patients over a 4-year period. No complications secondary to the use of hot water suction irrigation were encountered.
Simple immunoassay for detection of PCBs in transformer oil.
Glass, Thomas R; Ohmura, Naoya; Taemi, Yukihiro; Joh, Takashi
2005-07-01
A rapid and inexpensive procedure to detect polychlorinated biphenyls (PCBs) in transformer oil is needed to facilitate identification and removal of PCB contaminated transformers. Here we describe a simple two-step liquid-liquid extraction using acidic dimethyl sulfoxide in conjunction with an immunoassay for detecting PCBs in transformer oil. The process described is faster and simpler than any previous immunoassay while maintaining comparable detection limit and false negative rate. Cross reactivity data, characterizing the immunoassay response to the four Kanechlor technical mixtures of PCBs in oil, are presented. Forty-five used transformer oil samples were analyzed by gas chromatography-high-resolution mass spectrometry and were also evaluated using the immunoassay protocol developed. Results presented show zero false negatives at a 1.4 ppm nominal cutoff for the transformer oils analyzed.
Enabling Real-time Water Decision Support Services Using Model as a Service
NASA Astrophysics Data System (ADS)
Zhao, T.; Minsker, B. S.; Lee, J. S.; Salas, F. R.; Maidment, D. R.; David, C. H.
2014-12-01
Through application of computational methods and an integrated information system, data and river modeling services can help researchers and decision makers more rapidly understand river conditions under alternative scenarios. To enable this capability, workflows (i.e., analysis and model steps) are created and published as Web services delivered through an internet browser, including model inputs, a published workflow service, and visualized outputs. The RAPID model, which is a river routing model developed at University of Texas Austin for parallel computation of river discharge, has been implemented as a workflow and published as a Web application. This allows non-technical users to remotely execute the model and visualize results as a service through a simple Web interface. The model service and Web application has been prototyped in the San Antonio and Guadalupe River Basin in Texas, with input from university and agency partners. In the future, optimization model workflows will be developed to link with the RAPID model workflow to provide real-time water allocation decision support services.
From confluent human iPS cells to self-forming neural retina and retinal pigmented epithelium
Reichman, Sacha; Terray, Angélique; Slembrouck, Amélie; Nanteau, Céline; Orieux, Gaël; Habeler, Walter; Nandrot, Emeline F.; Sahel, José-Alain; Monville, Christelle; Goureau, Olivier
2014-01-01
Progress in retinal-cell therapy derived from human pluripotent stem cells currently faces technical challenges that require the development of easy and standardized protocols. Here, we developed a simple retinal differentiation method, based on confluent human induced pluripotent stem cells (hiPSC), bypassing embryoid body formation and the use of exogenous molecules, coating, or Matrigel. In 2 wk, we generated both retinal pigmented epithelial cells and self-forming neural retina (NR)-like structures containing retinal progenitor cells (RPCs). We report sequential differentiation from RPCs to the seven neuroretinal cell types in maturated NR-like structures as floating cultures, thereby revealing the multipotency of RPCs generated from integration-free hiPSCs. Furthermore, Notch pathway inhibition boosted the generation of photoreceptor precursor cells, crucial in establishing cell therapy strategies. This innovative process proposed here provides a readily efficient and scalable approach to produce retinal cells for regenerative medicine and for drug-screening purposes, as well as an in vitro model of human retinal development and disease. PMID:24912154
NASA Astrophysics Data System (ADS)
Wang, Chengpeng; Li, Fuguo; Liu, Juncheng
2018-04-01
The objectives of this work are to study the deformational feature, textures, microstructures, and dislocation configurations of ultrafine-grained copper processed by the process of elliptical cross-section spiral equal-channel extrusion (ECSEE). The deformation patterns of simple shear and pure shear in the ECSEE process were evaluated with the analytical method of geometric strain. The influence of the main technical parameters of ECSEE die on the effective strain distribution on the surface of ECSEE-fabricated samples was examined by the finite element simulation. The high friction factor could improve the effective strain accumulation of material deformation. Moreover, the pure copper sample fabricated by ECSEE ion shows a strong rotated cube shear texture. The refining mechanism of the dislocation deformation is dominant in copper processed by a single pass of ECSEE. The inhomogeneity of the micro-hardness distribution on the longitudinal section of the ECSEE-fabricated sample is consistent with the strain and microstructure distribution features.
Simplified Calculation Model and Experimental Study of Latticed Concrete-Gypsum Composite Panels
Jiang, Nan; Ma, Shaochun
2015-01-01
In order to address the performance complexity of the various constituent materials of (dense-column) latticed concrete-gypsum composite panels and the difficulty in the determination of the various elastic constants, this paper presented a detailed structural analysis of the (dense-column) latticed concrete-gypsum composite panel and proposed a feasible technical solution to simplified calculation. In conformity with mechanical rules, a typical panel element was selected and divided into two homogenous composite sub-elements and a secondary homogenous element, respectively for solution, thus establishing an equivalence of the composite panel to a simple homogenous panel and obtaining the effective formulas for calculating the various elastic constants. Finally, the calculation results and the experimental results were compared, which revealed that the calculation method was correct and reliable and could meet the calculation needs of practical engineering and provide a theoretical basis for simplified calculation for studies on composite panel elements and structures as well as a reference for calculations of other panels. PMID:28793631
Comparison between satellite and instrumental solar irradiance data at the city of Athens, Greece
NASA Astrophysics Data System (ADS)
Markonis, Yannis; Dimoulas, Thanos; Atalioti, Athina; Konstantinou, Charalampos; Kontini, Anna; Pipini, Magdalini-Io; Skarlatou, Eleni; Sarantopoulos, Vasilis; Tzouka, Katerina; Papalexiou, Simon; Koutsoyiannis, Demetris
2015-04-01
In this study, we examine and compare the statistical properties of satellite and instrumental solar irradiance data at the capital of Greece, Athens. Our aim is to determine whether satellite data are sufficient for the requirements of solar energy modelling applications. To this end we estimate the corresponding probability density functions, the auto-correlation functions and the parameters of some fitted simple stochastic models. We also investigate the effect of sample size to the variance in the temporal interpolation of daily time series. Finally, as an alternative, we examine if temperature can be used as a better predictor for the daily irradiance non-seasonal component instead of the satellite data. Acknowledgement: This research is conducted within the frame of the undergraduate course "Stochastic Methods in Water Resources" of the National Technical University of Athens (NTUA). The School of Civil Engineering of NTUA provided moral support for the participation of the students in the Assembly.
Celi, P; Sullivan, M; Evans, D
2010-02-01
Increasing interest in the role of oxidative stress (OS) in equine medicine has highlighted the need to develop reliable methods to quantify it. In this study we describe the effect of refrigeration (at 4 degrees C) on the stability of the reactive oxygen metabolites (d-ROMs) and biological antioxidant potential (BAP) tests carried out on 15 healthy horses. Blood samples, collected from the jugular vein, were immediately placed on ice and analysed using both the d-ROMs and BAP tests. Samples were also refrigerated at 4 degrees C and tested after 3, 7 and 24 h. The average results were similar for up to 24 h and minimal variations were found for each horse. The findings suggest that refrigeration is suitable for preserving equine blood samples for these assays and this approach will provide veterinarians with a technically simple, reliable test to measure OS under field conditions. Copyright (c) 2008 Elsevier Ltd. All rights reserved.
Measuring DNA Replication in Hypoxic Conditions.
Foskolou, Iosifina P; Biasoli, Deborah; Olcina, Monica M; Hammond, Ester M
2016-01-01
It is imperative that dividing cells maintain replication fork integrity in order to prevent DNA damage and cell death. The investigation of DNA replication is of high importance as alterations in this process can lead to genomic instability, a known causative factor of tumor development. A simple, sensitive, and informative technique which enables the study of DNA replication, is the DNA fiber assay, an adaptation of which is described in this chapter. The DNA fiber method is a powerful tool, which allows the quantitative and qualitative analysis of DNA replication at the single molecule level. The sequential pulse labeling of live cells with two thymidine analogues and the subsequent detection with specific antibodies and fluorescence imaging allows direct examination of sites of DNA synthesis. In this chapter, we describe how this assay can be performed in conditions of low oxygen levels (hypoxia)-a physiologically relevant stress that occurs in most solid tumors. Moreover, we suggest ways on how to overcome the technical problems that arise while using the hypoxic chambers.
Fourier-interpolation superresolution optical fluctuation imaging (fSOFi) (Conference Presentation)
NASA Astrophysics Data System (ADS)
Enderlein, Joerg; Stein, Simon C.; Huss, Anja; Hähnel, Dirk; Gregor, Ingo
2016-02-01
Stochastic Optical Fluctuation Imaging (SOFI) is a superresolution fluorescence microscopy technique which allows to enhance the spatial resolution of an image by evaluating the temporal fluctuations of blinking fluorescent emitters. SOFI is not based on the identification and localization of single molecules such as in the widely used Photoactivation Localization Microsopy (PALM) or Stochastic Optical Reconstruction Microscopy (STORM), but computes a superresolved image via temporal cumulants from a recorded movie. A technical challenge hereby is that, when directly applying the SOFI algorithm to a movie of raw images, the pixel size of the final SOFI image is the same as that of the original images, which becomes problematic when the final SOFI resolution is much smaller than this value. In the past, sophisticated cross-correlation schemes have been used for tackling this problem. Here, we present an alternative, exact, straightforward, and simple solution using an interpolation scheme based on Fourier transforms. We exemplify the method on simulated and experimental data.
The measurement of Eustachian tube function in a hyperbaric chamber using an ear canal microphone.
Fischer, Hans-Georg; Koch, Andreas; Kähler, Wataru; Pohl, Michael; Pau, Hans-Wilhelm; Zehlicke, Thorsten
2016-03-01
The purpose of this study was to further the understanding of the opening of the Eustachian tube in relation to changes in barometric pressure. An ear canal microphone was used to measure the specific sounds related to tube opening and possible eardrum movements. Five subjects with normal tube function were examined in a hyperbaric chamber (up to 304 kPa). All active and passive equalization events were recorded and correlated with the subjectively perceived pressure regulation in the measured ear. The signals recorded were clear and reproducible. The acoustic analysis distinguished between the different kinds of equalization. Subjective impressions were confirmed by the recorded frequency of acoustic phenomena (clicks). During compression, the sequence of active equalization manoeuvres was in a more regular and steady pattern than during decompression, when the click sounds varied. The study established a simple technical method for analyzing the function of the Eustachian tube and provided new information about barometric pressure regulation of the middle ear.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pasztor, G.; Schmidt, C.
The behavior of NbTi superconductors under dynamic mechanical stress was investigated. A training effect was found in short-sample tests when the conductor was strained in a magnetic field and with a transport current applied. Possible mechanisms are discussed which were proposed to explain training in short samples and in magnets. A stress-induced microplastic as well as an incomplete pseudoelastic behavior of NbTi was detected by monitoring acoustic emission. The experiments support the hypothesis that microplastic or shape memory effects in NbTi involving dislocation processes are responsible for training. The minimum energy needed to induce a normal transition in short-sample testsmore » is calculated with a computer program, which gives the exact solution of the heat equation. A prestrain treatment of the conductor at room temperature is shown to be a simple method of reducing training of short samples and of magnets. This is a direct proof that the same mechanisms are involved in both cases.« less
A framework for sensitivity analysis of decision trees.
Kamiński, Bogumił; Jakubczyk, Michał; Szufel, Przemysław
2018-01-01
In the paper, we consider sequential decision problems with uncertainty, represented as decision trees. Sensitivity analysis is always a crucial element of decision making and in decision trees it often focuses on probabilities. In the stochastic model considered, the user often has only limited information about the true values of probabilities. We develop a framework for performing sensitivity analysis of optimal strategies accounting for this distributional uncertainty. We design this robust optimization approach in an intuitive and not overly technical way, to make it simple to apply in daily managerial practice. The proposed framework allows for (1) analysis of the stability of the expected-value-maximizing strategy and (2) identification of strategies which are robust with respect to pessimistic/optimistic/mode-favoring perturbations of probabilities. We verify the properties of our approach in two cases: (a) probabilities in a tree are the primitives of the model and can be modified independently; (b) probabilities in a tree reflect some underlying, structural probabilities, and are interrelated. We provide a free software tool implementing the methods described.
Simplified Calculation Model and Experimental Study of Latticed Concrete-Gypsum Composite Panels.
Jiang, Nan; Ma, Shaochun
2015-10-27
In order to address the performance complexity of the various constituent materials of (dense-column) latticed concrete-gypsum composite panels and the difficulty in the determination of the various elastic constants, this paper presented a detailed structural analysis of the (dense-column) latticed concrete-gypsum composite panel and proposed a feasible technical solution to simplified calculation. In conformity with mechanical rules, a typical panel element was selected and divided into two homogenous composite sub-elements and a secondary homogenous element, respectively for solution, thus establishing an equivalence of the composite panel to a simple homogenous panel and obtaining the effective formulas for calculating the various elastic constants. Finally, the calculation results and the experimental results were compared, which revealed that the calculation method was correct and reliable and could meet the calculation needs of practical engineering and provide a theoretical basis for simplified calculation for studies on composite panel elements and structures as well as a reference for calculations of other panels.
Caronna, Roberto; Peparini, Nadia; Cosimo Russillo, Gabriele; Antonio Rogano, Adolfo; Dinatale, Giuseppe; Chirletti, Piero
2012-01-01
Introduction. The best pancreatic anastomosis technique after pancreaticoduodenectomy (PD) is still debated. Pancreatic fistula (PF) is the most important complication but is also related to postoperative bleedings and pancreatic remnant involution. We support pancreaticojejuno anastomosis (PJ) advantages describing our technique with brief technical considerations. Materials and Methods. 89 consecutive patients underwent PD with suprapyloric gastric resection and double loop reconstruction. Pancreaticojejunal end-to-end anastomosis was done by simple invagination with a single layer of interrupted pledget-supported Ticron stitches. Results. Pancreatic fistula occurred in seven patients (7.8%): six cases of grade A fistula resolved spontaneously, and in only one case of grade B fistula percutaneous drainage was necessary. Postoperative hemorrhage occurred in only two (2.2%) of 89 patients. Conclusion. Pancreaticojejunostomy with minor changes in anastomotic techniques can contribute to improvement of the outcome of Roux-en-Y reconstruction regarding PF and other related complications. The particular reconstruction reported seems also to preserve the pancreatic exocrine function.
Caronna, Roberto; Peparini, Nadia; Cosimo Russillo, Gabriele; Antonio Rogano, Adolfo; Dinatale, Giuseppe; Chirletti, Piero
2012-01-01
Introduction. The best pancreatic anastomosis technique after pancreaticoduodenectomy (PD) is still debated. Pancreatic fistula (PF) is the most important complication but is also related to postoperative bleedings and pancreatic remnant involution. We support pancreaticojejuno anastomosis (PJ) advantages describing our technique with brief technical considerations. Materials and Methods. 89 consecutive patients underwent PD with suprapyloric gastric resection and double loop reconstruction. Pancreaticojejunal end-to-end anastomosis was done by simple invagination with a single layer of interrupted pledget-supported Ticron stitches. Results. Pancreatic fistula occurred in seven patients (7.8%): six cases of grade A fistula resolved spontaneously, and in only one case of grade B fistula percutaneous drainage was necessary. Postoperative hemorrhage occurred in only two (2.2%) of 89 patients. Conclusion. Pancreaticojejunostomy with minor changes in anastomotic techniques can contribute to improvement of the outcome of Roux-en-Y reconstruction regarding PF and other related complications. The particular reconstruction reported seems also to preserve the pancreatic exocrine function. PMID:22489265
Stability of large-scale systems with stable and unstable subsystems.
NASA Technical Reports Server (NTRS)
Grujic, Lj. T.; Siljak, D. D.
1972-01-01
The purpose of this paper is to develop new methods for constructing vector Liapunov functions and broaden the application of Liapunov's theory to stability analysis of large-scale dynamic systems. The application, so far limited by the assumption that the large-scale systems are composed of exponentially stable subsystems, is extended via the general concept of comparison functions to systems which can be decomposed into asymptotically stable subsystems. Asymptotic stability of the composite system is tested by a simple algebraic criterion. With minor technical adjustments, the same criterion can be used to determine connective asymptotic stability of large-scale systems subject to structural perturbations. By redefining the constraints imposed on the interconnections among the subsystems, the considered class of systems is broadened in an essential way to include composite systems with unstable subsystems. In this way, the theory is brought substantially closer to reality since stability of all subsystems is no longer a necessary assumption in establishing stability of the overall composite system.
2012-01-01
Background The introduction of a new method of transmitting prescriptions from general practices to community pharmacies in England (Electronic Prescription Service Release 2 (EPS2)) has generated debate on how it will change work practice. As EPS2 will be a key technical element in dispensing, we reviewed the literature to find that there were no studies on how social and technical elements come together to form work practice in community pharmacies. This means the debate has little point of reference. Our aim therefore was to study the ways social and technical elements of a community pharmacy are used to achieve dispensing through the development of a conceptual model on pharmacy work practice, and to consider how a core technical element such the EPS2 could change work practice. Method We used ethnographic methods inclusive of case-study observations and interviews to collect qualitative data from 15 community pharmacies that were in the process of adopting or were soon to adopt EPS2. We analysed the case studies thematically and used rigorous multi-dimensional and multi-disciplinary interpretive validation techniques to cross analyse findings. Results In practice, dispensing procedures were not designed to take into account variations in human and technical integration, and assumed that repetitive and collective use of socio-technical elements were at a constant. Variables such as availability of social and technical resources, and technical know-how of staff were not taken into account in formalised procedures. Yet community pharmacies were found to adapt their dispensing in relation to the balance of social and technical elements available, and how much of the social and technical elements they were willing to integrate into dispensing. While some integrated as few technical elements as possible, some depended entirely on technical artefacts. This pattern also applied to the social elements of dispensing. Through the conceptual model development process, we identified three approaches community pharmacies used to appropriate procedures in practice. These were ‘technically oriented’, ‘improvising’ or ‘socially oriented’. Conclusion We offer a model of different work approaches community pharmacies use to dispense, which suggests that when adopting a core technical element such as the EPS2 system of dispensing there could be variations in its successful adoption. Technically oriented pharmacies might find it easiest to integrate a similar artefact into work practice although needs EPS2 to synchronise effectively with existing technologies. Pharmacies adopting an improvising-approach have the potential to improve how they organise dispensing through EPS2 although they will need to improve how they apply their operating procedures. Socially oriented pharmacies will need to dramatically adapt their approach to dispensing since they usually rely on few technical tools. PMID:23256484
NASA Technical Reports Server (NTRS)
Mathes, J. C. (Compiler); Pinelli, T. E. (Compiler)
1981-01-01
Proceeding of the technical communication sessions at the 32nd annual meeting of the Conference on College Composition and Communication held in Dallas, Texas, March 26-28, 1981 are summarized. The proceeding suggest that technical communication has become an important subfield and is becoming an intrinsic part of many undergraduate curricula. Technical communication as a separate discipline, however, is relatively new. For that reason, proceedings that can make current research available as quickly as possible are suggested for preparation. The following topics were addressed: (1) a history and definition of technical writing, (2) the case method is technical communication (3) teaching technical writing (4) oral communication and rhetorical theory, and (5) new approaches in and practical applications of technical writing.
Feasibility of a simple method of hybrid collimation for megavoltage grid therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Almendral, Pedro; Mancha, Pedro J.; Roberto, Daniel
2013-05-15
Purpose: Megavoltage grid therapy is currently delivered with step-and-shoot multisegment techniques or using a high attenuation block with divergent holes. However, the commercial availability of grid blocks is limited, their construction is difficult, and step-and-shoot techniques require longer treatment times and are not practical with some multileaf collimators. This work studies the feasibility of a hybrid collimation system for grid therapy that does not require multiple segments and can be easily implemented with widely available technical means. Methods: The authors have developed a system to generate a grid of beamlets by the simultaneous use of two perpendicular sets of equallymore » spaced leaves that project stripe patterns in orthogonal directions. One of them is generated with the multileaf collimator integrated in the accelerator and the other with an in-house made collimator constructed with a low melting point alloy commonly available at radiation oncology departments. The characteristics of the grid fields for 6 and 18 MV have been studied with a shielded diode, an unshielded diode, and radiochromic film. Results: The grid obtained with the hybrid collimation is similar to some of the grids used clinically with respect to the beamlet size (about 1 cm) and the percentage of open beam (1/4 of the total field). The grid fields are less penetrating than the open fields of the same energy. Depending on the depth and the direction of the profiles (diagonal or along the principal axes), the measured valley-to-peak dose ratios range from 5% to 16% for 6 MV and from 9% to 20% for 18 MV. All the detectors yield similar results in the measurement of profiles and percent depth dose, but the shielded diode seems to overestimate the output factors. Conclusions: The combination of two stripe pattern collimators in orthogonal directions is a feasible method to obtain two-dimensional arrays of beamlets and has potential usefulness as an efficient way to deliver grid therapy. The implementation of this method is technically simpler than the construction of a conventional grid block.« less
NASA Technical Reports Server (NTRS)
Singh, M.
2013-01-01
Ceramic integration technologies enable hierarchical design and manufacturing of intricate ceramic and composite parts starting with geometrically simpler units that are subsequently joined to themselves and/or to metals to create components with progressively higher levels of complexity and functionality. However, for the development of robust and reliable integrated systems with optimum performance for high temperature applications, detailed understanding of various thermochemical and thermomechanical factors is critical. Different technical approaches are required for the integration of ceramic to ceramic and ceramic to metal systems. Active metal brazing, in particular, is a simple and cost-effective method to integrate ceramic to metallic components. Active braze alloys usually contain a reactive filler metal (e.g., Ti, Cr, V, Hf etc) that promotes wettability and spreading by inducing chemical reactions with the ceramics and composites. In this presentation, various examples of brazing of silicon nitride to themselves and to metallic systems are presented. Other examples of joining of ceramic composites (C/SiC and SiC/SiC) using ceramic interlayers and the resulting microstructures are also presented. Thermomechanical characterization of joints is presented for both types of systems. In addition, various challenges and opportunities in design, fabrication, and testing of integrated similar (ceramic-ceramic) and dissimilar (ceramic-metal) material systems will be discussed. Potential opportunities and need for the development of innovative design philosophies, approaches, and integrated system testing under simulated application conditions will also be presented.
Andreishchev, A R; Nicot, R; Ferri, J
2014-11-01
Mandibular angle resection is rarely used, but is a highly effective means of correcting facial defects. We report a mandibular angle resection technique associated with the removal of a part of hypertrophic masseter muscles and resection of buccal fat pad. Anatomical reminders: the most important entities are the facial artery and vein, crossing the lower margin of the jaw just in front of the anterior boarder of the masseter muscle and the temporomaxillary vein, passing through the temporomaxillary fossa; preoperative aspects: the preoperative examination included a radiological assessment of the shape and size of the mandibular angle; surgical technique: an intra-oral approach was usually used. The most effective and convenient method for the osteotomy was using a reciprocating saw. This technique allowed achieving a smooth contour of masseter muscles during masticatory movements or at rest. Eleven mandibular angle resections were performed from 2001 to 2009. The surgery was supplemented by remodeling the lower margin of the jaw for 5 other patients. No permanent facial palsy was noted. One patient presented a unilateral long-term loss of sensitivity of the lower lip and chin. This surgical technique if simple even requires using good technical equipment, and observing a set of rules. Using these principles allows simplifying the surgical technique, and decreasing its morbidity. A part of the masseter muscles and the buccal fat pad can sometimes be resected to improve the morphological results. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
[Differential echographic diagnosis in small tissue areas--exemplified by the orbits].
Buschmann, W; Haigis, W
1982-12-01
Measurement-based ultrasonography proved mandatory in ophthalmic diagnostic work. It provides comparable examination conditions and therefore, comparable results, in contrast to simple, empirical ultrasonic examination. Measurement methods which can be easily applied under clinical conditions have been developed for determination of those technical characteristics of the apparatus and transducer probes which proved decisive for the diagnostic results. Some echographic criteria can be additionally or better evaluated using this basis. All echo-amplitude measurements should be related to a well-defined test-reflector echo. In addition to sensitivity and resolution, frequency and frequency spectrum are especially important. Manufacturer's data have proved insufficient up to now, insufficient; even within one manufacturer's series of one equipment or transducer probe type considerable deviations from the declared data have been found. Such deviations may mimick pathologic alterations in the echograms. The size of a lesion area can be better evaluated when using well-defined technical conditions. The echographic presentation of tissue structures in the depth is especially dependent on frequency and on the frequency spectrum. Pathologic alterations of tissues may cause changes in the ultrasound attenuation which results in emphasized or reduced presentation of echoes from normal structures behind the lesion area. Tissue differentiation should be based on additional A-scan echograms. Computerized echogram averaging provides a more reliable evaluation of echo amplitudes and ultrasound attenuation. Use of measurement-based ultrasonography permits to compare measured echo-amplitudes and ultrasound attenuation with the results of other working groups, even if these are based on other equipment and transducers.
ERLN Technical Support for Labs
The Environmental Response Laboratory Network provides policies and guidance on lab and data requirements, Standardized Analytical Methods, and technical support for water and radiological sampling and analysis
NASA Astrophysics Data System (ADS)
Afanasyev, A. P.; Bazhenov, R. I.; Luchaninov, D. V.
2018-05-01
The main purpose of the research is to develop techniques for defining the best technical and economic trajectories of cables in urban power systems. The proposed algorithms of calculation of the routes for laying cables take into consideration topological, technical and economic features of the cabling. The discrete option of an algorithm Fast marching method is applied as a calculating tool. It has certain advantages compared to other approaches. In particular, this algorithm is cost-effective to compute, therefore, it is not iterative. Trajectories of received laying cables are considered as optimal ones from the point of view of technical and economic criteria. They correspond to the present rules of modern urban development.
Technical aspects and limitations of fractional flow reserve measurement.
Jerabek, Stepan; Kovarnik, Tomas
2018-02-27
The only indication for coronary revascularization is elimination of ischaemia. Invasive hemodynamic methods (fractional flow reserve - FFR and instantaneous wave-free ratio (iFR) are superior to coronary angiography in detection of lesions causing myocardial ischaemia. Current European guidelines for myocardial revascularization recommend using of FFR for detection of functional assessment of lesions severity in category IA and number of these procedures increases. However, routine usage of these methods requires knowledge of technical requirements and limitations. The aim of the study is to summarise good clinical practice for FFR and iFR measurements with explanation of possible technical challenges, that are necessary for increasing of measurement accuracy. Authors describe frequent technical mistakes and malpractice during invasive assessment of lesion severity in coronary arteries.