Sample records for technique previously reported

  1. Serum proteins by capillary zone electrophoresis: approaches to the definition of reference values.

    PubMed

    Petrini, C; Alessio, M G; Scapellato, L; Brambilla, S; Franzini, C

    1999-10-01

    The Paragon CZE 2000 (Beckman Analytical, Milan, Italy) is an automatic dedicated capillary zone electrophoresis (CZE) system, producing a five-zone serum protein pattern with quantitative estimation of the zones. With the view of substituting this instrument for two previously used serum protein electrophoresis techniques, we planned to produce reference values for the "new" systems leading to compatible interpretation of the results. High resolution cellulose acetate electrophoresis with visual inspection and descriptive reporting (HR-CAE) and five-zone cellulose acetate electrophoresis with densitometry (CAE-D) were the previously used techniques. Serum samples (n = 167) giving "normal pattern" with HR-CAE were assayed with the CZE system, and the results were statistically assessed to yield 0.95 reference intervals. One thousand normal and pathological serum samples were then assayed with the CAE-D and the CZE techniques, and the regression equations of the CAE-D values over the CZE values for the five zones were used to transform the CAE-D reference limits into the CZE reference limits. The two sets of reference values thereby produced were in good agreement with each other and also with reference values previously reported for the CZE system. Thus, reference values for the CZE techniques permit interpretation of results coherent with the previously used techniques and reporting modes.

  2. Transformer Incipient Fault Prediction Using Combined Artificial Neural Network and Various Particle Swarm Optimisation Techniques.

    PubMed

    Illias, Hazlee Azil; Chai, Xin Rui; Abu Bakar, Ab Halim; Mokhlis, Hazlie

    2015-01-01

    It is important to predict the incipient fault in transformer oil accurately so that the maintenance of transformer oil can be performed correctly, reducing the cost of maintenance and minimise the error. Dissolved gas analysis (DGA) has been widely used to predict the incipient fault in power transformers. However, sometimes the existing DGA methods yield inaccurate prediction of the incipient fault in transformer oil because each method is only suitable for certain conditions. Many previous works have reported on the use of intelligence methods to predict the transformer faults. However, it is believed that the accuracy of the previously proposed methods can still be improved. Since artificial neural network (ANN) and particle swarm optimisation (PSO) techniques have never been used in the previously reported work, this work proposes a combination of ANN and various PSO techniques to predict the transformer incipient fault. The advantages of PSO are simplicity and easy implementation. The effectiveness of various PSO techniques in combination with ANN is validated by comparison with the results from the actual fault diagnosis, an existing diagnosis method and ANN alone. Comparison of the results from the proposed methods with the previously reported work was also performed to show the improvement of the proposed methods. It was found that the proposed ANN-Evolutionary PSO method yields the highest percentage of correct identification for transformer fault type than the existing diagnosis method and previously reported works.

  3. Transformer Incipient Fault Prediction Using Combined Artificial Neural Network and Various Particle Swarm Optimisation Techniques

    PubMed Central

    2015-01-01

    It is important to predict the incipient fault in transformer oil accurately so that the maintenance of transformer oil can be performed correctly, reducing the cost of maintenance and minimise the error. Dissolved gas analysis (DGA) has been widely used to predict the incipient fault in power transformers. However, sometimes the existing DGA methods yield inaccurate prediction of the incipient fault in transformer oil because each method is only suitable for certain conditions. Many previous works have reported on the use of intelligence methods to predict the transformer faults. However, it is believed that the accuracy of the previously proposed methods can still be improved. Since artificial neural network (ANN) and particle swarm optimisation (PSO) techniques have never been used in the previously reported work, this work proposes a combination of ANN and various PSO techniques to predict the transformer incipient fault. The advantages of PSO are simplicity and easy implementation. The effectiveness of various PSO techniques in combination with ANN is validated by comparison with the results from the actual fault diagnosis, an existing diagnosis method and ANN alone. Comparison of the results from the proposed methods with the previously reported work was also performed to show the improvement of the proposed methods. It was found that the proposed ANN-Evolutionary PSO method yields the highest percentage of correct identification for transformer fault type than the existing diagnosis method and previously reported works. PMID:26103634

  4. Internal bone transport using a cannulated screw as a mounting device in the treatment of a post-infective ulnar defect.

    PubMed

    Tsitskaris, Konstantinos; Havard, Heledd; Bijlsma, Paulien; Hill, Robert A

    2016-04-01

    Bone transport techniques can be used to address the segmental bone loss occurring after debridement for infection. Secure fixation of the bone transport construct to the bone transport segment can be challenging, particularly if the bone is small and osteopenic. We report a case of a segmental ulnar bone defect in a young child treated with internal bone transport using a cannulated screw as the mounting device. We found this technique particularly useful in the treatment of bone loss secondary to infection, where previous treatment and prolonged immobilisation had led to osteopenia. This technique has not been previously reported.

  5. Minimally invasive computer-assisted stereotactic fenestration of an aqueductal cyst: case report.

    PubMed

    Fonoff, E T; Gentil, A F; Padilha, P M; Teixeira, M J

    2010-02-01

    Current advances in frame modeling and computer software allow stereotactic procedures to be performed with great accuracy and minimal risk of neural tissue or vascular injury. In this report we associate a previously described minimally invasive stereotactic technique with state-of-the-art 3D computer guidance technology to successfully treat a 55-year-old patient with an arachnoidal cyst obstructing the aqueduct of Sylvius. We provide detailed technical information and discuss how this technique deals with previous limitations for stereotactic manipulation of the aqueductal region. We further discuss current advances in neuroendoscopy for treating obstructive hydrocephalus and make comparisons with our proposed technique. We advocate that this technique is not only capable of treating this pathology but it also has the advantages to enable reestablishment of physiological CSF flow thus preventing future brainstem compression by cyst enlargement. (c) Georg Thieme Verlag KG Stuttgart . New York.

  6. Spontaneous Intrahepatic Portal Venous Shunt: Presentation and Endovascular Treatment.

    PubMed

    Sheth, Nakul; Sabbah, Nathanael; Contractor, Sohail

    2016-07-01

    Spontaneous intrahepatic portal venous shunts are rare with only few case reports published. Treatments using various endovascular techniques have been described, although no single technique has been shown to be preferred. We present a patient who was referred for treatment of a spontaneous portal venous shunt and describe our treatment approach and present a review on previously reported cases. © The Author(s) 2016.

  7. Classroom Dialogue and Science Achievement.

    ERIC Educational Resources Information Center

    Clarke, John A.

    This study reports the application to classroom dialogue of the Thematic and Structural Analysis (TSA) Technique which has been used previously in the analysis of text materials. The TSA Technique identifies themes (word clusters) and their structural relationship throughout sequentially organized material. Dialogues from four Year 8 science…

  8. Introduction to 2005 National Technical Report

    Treesearch

    Mark J. Ambrose

    2007-01-01

    This annual technical report is a product of the Forest Health Monitoring (FHM) program. The report provides information about a variety of issues relating to forest health at the national scale. Previous FHM national reports have had a dual focus of presenting analyses of the latest available data and showcasing innovative techniques for analyzing forest health data....

  9. The identification of synthetic organic pigments in modern paints and modern paintings using pyrolysis-gas chromatography-mass spectrometry.

    PubMed

    Russell, Joanna; Singer, Brian W; Perry, Justin J; Bacon, Anne

    2011-05-01

    A collection of more than 70 synthetic organic pigments were analysed using pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS). We report on the analysis of diketo-pyrrolo-pyrrole, isoindolinone and perylene pigments which are classes not previously reported as being analysed by this technique. We also report on a number of azo pigments (2-naphthol, naphthol AS, arylide, diarylide, benzimidazolone and disazo condensation pigments) and phthalocyanine pigments, the Py-GC-MS analysis of which has not been previously reported. The members of each class were found to fragment in a consistent way and the pyrolysis products are reported. The technique was successfully applied to the analysis of paints used by the artist Francis Bacon (1909-1992), to simultaneously identify synthetic organic pigments and synthetic binding media in two samples of paint taken from Bacon's studio and micro-samples taken from three of his paintings and one painting attributed to him.

  10. Space Shuttle propulsion parameter estimation using optimal estimation techniques

    NASA Technical Reports Server (NTRS)

    1983-01-01

    The fifth monthly progress report includes corrections and additions to the previously submitted reports. The addition of the SRB propellant thickness as a state variable is included with the associated partial derivatives. During this reporting period, preliminary results of the estimation program checkout was presented to NASA technical personnel.

  11. Flipping the Classroom: An Empirical Study Examining Student Learning

    ERIC Educational Resources Information Center

    Sparks, Roland J.

    2013-01-01

    Flipping the classroom is the latest reported teaching technique to improve student learning at all levels. Prior studies showed significant increases in learning by employing this technique. However, an examination of the previous studies indicates significant flaws in the testing procedure controls. Moreover, most studies were based on anecdotal…

  12. Innovative signal processing for Johnson Noise thermometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ezell, N. Dianne Bull; Britton, Jr, Charles L.; Roberts, Michael

    This report summarizes the newly developed algorithm that subtracted the Electromagnetic Interference (EMI). The EMI performance is very important to this measurement because any interference in the form on pickup from external signal sources from such as fluorescent lighting ballasts, motors, etc. can skew the measurement. Two methods of removing EMI were developed and tested at various locations. This report also summarizes the testing performed at different facilities outside Oak Ridge National Laboratory using both EMI removal techniques. The first EMI removal technique reviewed in previous milestone reports and therefore this report will detail the second method.

  13. Anteriorly placed tumors to the conus: removal by interradicular window.

    PubMed

    Ciappetta, P; Taurone, S; Spoletini, M; Artico, M

    2017-01-01

    Tumors anteriorly situated to the medullary conus are rarely encountered and represent a true surgical challenge. We examined the literature on this topic, concluding that there are no previous reports on alternative surgical techniques different to the traditional one. We report two cases of intradural extramedullary tumor operated on by a technique performed through a window opened between the spinal roots, which allows an easy, effective and useful resection. We describe a new operative technique which ensures a complete removal of these tumors and discuss clinical implications in the light of the available literature on this topic.

  14. An Evaluation of Student Team Teaching in Sophomore Physics Classes. Final Report.

    ERIC Educational Resources Information Center

    Thrasher, Paul H.

    In the present document the effectiveness of a student team teaching technique is evaluated in comparison with the lecture method. The team teaching technique, previously used for upper division and graduate physics courses, was, for this study, used in a sophomore physics, electricity and magnetism course for engineers, mathematicians, chemists,…

  15. Local repair of stoma prolapse: Case report of an in vivo application of linear stapler devices.

    PubMed

    Monette, Margaret M; Harney, Rodney T; Morris, Melanie S; Chu, Daniel I

    2016-11-01

    One of the most common late complications following stoma construction is prolapse. Although the majority of prolapse can be managed conservatively, surgical revision is required with incarceration/strangulation and in certain cases laparotomy and/or stoma reversal are not appropriate. This report will inform surgeons on safe and effective approaches to revising prolapsed stomas using local techniques. A 58 year old female with an obstructing rectal cancer previously received a diverting transverse loop colostomy. On completion of neoadjuvant treatment, re-staging found new lung metastases. She was scheduled for further chemotherapy but incarcerated a prolapsed segment of her loop colostomy. As there was no plan to resect her primary rectal tumor at the time, a local revision was preferred. Linear staplers were applied to the prolapsed stoma in step-wise fashion to locally revise the incarcerated prolapse. Post-operative recovery was satisfactory with no complications or recurrence of prolapse. We detail in step-wise fashion a technique using linear stapler devices that can be used to locally revise prolapsed stoma segments and therefore avoid a laparotomy. The procedure is technically easy to perform with satisfactory post-operative outcomes. We additionally review all previous reports of local repairs and show the evolution of local prolapse repair to the currently reported technique. This report offers surgeons an alternative, efficient and effective option for addressing the complications of stoma prolapse. While future studies are needed to assess long-term outcomes, in the short-term, our report confirms the safety and effectiveness of this local technique.

  16. The electromagnetic modeling of thin apertures using the finite-difference time-domain technique

    NASA Technical Reports Server (NTRS)

    Demarest, Kenneth R.

    1987-01-01

    A technique which computes transient electromagnetic responses of narrow apertures in complex conducting scatterers was implemented as an extension of previously developed Finite-Difference Time-Domain (FDTD) computer codes. Although these apertures are narrow with respect to the wavelengths contained within the power spectrum of excitation, this technique does not require significantly more computer resources to attain the increased resolution at the apertures. In the report, an analytical technique which utilizes Babinet's principle to model the apertures is developed, and an FDTD computer code which utilizes this technique is described.

  17. Environmental stress cracking of polymers

    NASA Technical Reports Server (NTRS)

    Mahan, K. I.

    1980-01-01

    A two point bending method for use in studying the environmental stress cracking and crazing phenomena is described and demonstrated for a variety of polymer/solvent systems. Critical strain values obtained from these curves are reported for various polymer/solvent systems including a considerable number of systems for which critical strain values have not been previously reported. Polymers studied using this technique include polycarbonate (PC), ABS, high impact styrene (HIS), polyphenylene oxide (PPO), and polymethyl methacrylate (PMMA). Critical strain values obtained using this method compared favorably with available existing data. The major advantage of the technique is the ability to obtain time vs. strain curves over a short period of time. The data obtained suggests that over a short period of time the transition in most of the polymer solvent systems is more gradual than previously believed.

  18. Evaluation of control laws and actuator locations for control systems applicable to deformable astronomical telescope mirrors

    NASA Technical Reports Server (NTRS)

    Ostroff, A. J.

    1973-01-01

    Some of the major difficulties associated with large orbiting astronomical telescopes are the cost of manufacturing the primary mirror to precise tolerances and the maintaining of diffraction-limited tolerances while in orbit. One successfully demonstrated approach for minimizing these problem areas is the technique of actively deforming the primary mirror by applying discrete forces to the rear of the mirror. A modal control technique, as applied to active optics, has previously been developed and analyzed. The modal control technique represents the plant to be controlled in terms of its eigenvalues and eigenfunctions which are estimated via numerical approximation techniques. The report includes an extension of previous work using the modal control technique and also describes an optimal feedback controller. The equations for both control laws are developed in state-space differential form and include such considerations as stability, controllability, and observability. These equations are general and allow the incorporation of various mode-analyzer designs; two design approaches are presented. The report also includes a technique for placing actuator and sensor locations at points on the mirror based upon the flexibility matrix of the uncontrolled or unobserved modes of the structure. The locations selected by this technique are used in the computer runs which are described. The results are based upon three different initial error distributions, two mode-analyzer designs, and both the modal and optimal control laws.

  19. Development of a model for predicting NASA/MSFC program success

    NASA Technical Reports Server (NTRS)

    Riggs, Jeffrey; Miller, Tracy; Finley, Rosemary

    1990-01-01

    Research conducted during the execution of a previous contract (NAS8-36955/0039) firmly established the feasibility of developing a tool to aid decision makers in predicting the potential success of proposed projects. The final report from that investigation contains an outline of the method to be applied in developing this Project Success Predictor Model. As a follow-on to the previous study, this report describes in detail the development of this model and includes full explanation of the data-gathering techniques used to poll expert opinion. The report includes the presentation of the model code itself.

  20. Left ventricular assist device implantation in a patient who had previously undergone apical myectomy for hypertrophic cardiomyopathy.

    PubMed

    Cho, Yang Hyun; Deo, Salil V; Topilsky, Yan; Grogan, Martha A; Park, Soon J

    2012-03-01

    Apical hypertrophy is a rare variant of hypertropic cardiomyopathy. These patients may present with end-stage congestive heart failure subsequent to long standing diastolic dysfunction. We report the technique for left ventricular assist device insertion in a patient with previous apical myectomy for hypertrophic cardiomyopathy. © 2012 Wiley Periodicals, Inc.

  1. Yellowstone grizzly bear investigations: Annual report of the Interagency Grizzly Bear Study Team, 2006

    USGS Publications Warehouse

    Schwartz, Charles C.; Haroldson, Mark A.; West, Karrie K.

    2007-01-01

    The annual reports of the IGBST summarize annual data collection. Because additional information can be obtained after publication, data summaries are subject to change. For that reason, data analyses and summaries presented in this report supersede all previously published data. The study area and sampling techniques are reported by Blanchard (1985), Mattson et al. (1991 a), and Haroldson et al. (1998).

  2. New Crustal Thickness for Djibouti, Afar, Using Seismic Techniques

    NASA Astrophysics Data System (ADS)

    Dugda, Mulugeta; Bililign, Solomon

    2008-10-01

    Crustal thickness and Poisson's ratio for the seismic station ATD in Djibouti, Afar, has been investigated using two seismic techniques (H-κ stacking of receiver functions and a joint inversion of receiver functions and surface wave group velocities). Both techniques give consistent results of crustal thickness 23±1.5 km and Poisson's ratio 0.31±0.02. We also determined a mean P-wave velocity (Vp) of ˜6.2 km/s but ˜6.9-7.0 km/s below a 2 - 5 km thick low velocity layer at the surface. Previous studies of crustal structure for Djibouti reported that the crust is 6 to 11 km thick while our study shows that the crust beneath Djibouti is between 20 and 25 km. This study argues that the crustal thickness values reported for Djibouti for the last 3 decades were not consistent with the reports for the other neighboring region in central and eastern Afar. Our results for ATD in Djibouti, however, are consistent with the reports of crustal thickness in many other parts of central and eastern Afar. We attribute this difference to how the Moho (the crust-mantle discontinuity) is defined (an increase of Vp to 7.4 km/s in this study vs. 6.9 km/s in previous studies).

  3. Knee arthrodesis using a short locked intramedullary nail. A new technique.

    PubMed

    Cheng, S L; Gross, A E

    1995-01-01

    This article reports on the use of a new intramedullary nail designed specifically for fixation of knee fusions. The nail is a short locked stainless steel nail that is inserted through a single anterior knee incision and uses an outrigger targeting rod to guide the insertion of the locking screws. The successful use of this technique is illustrated in two cases. The advantages of this nail compared with previously reported techniques of fixation for knee fusions are that the short locked nail avoids the second incision required for the insertion of long knee fusion nails, the bulkiness of the double plating technique in the relatively subcutaneous anterior knee area, and the difficulties inherent with the prolonged use of pins for external fixation.

  4. Factors influencing behavior guidance: a survey of practicing pediatric dentists.

    PubMed

    Juntgen, Laura M; Sanders, Brian J; Walker, Laquia A; Jones, James E; Weddell, James A; Tomlin, Angela M; Eckert, George; Maupome, Gerardo

    2013-01-01

    The purpose of this study was to identify factors influencing behavior guidance technique utilization among practicing pediatric dentists and explore potential barriers to the incorporation of previously unused techniques. The data for this study were obtained from a web-based survey containing 15 multiple choice questions concerning the practitioners' past, current, and anticipated future behavior guidance technique utilization. Most respondents received hands-on training in 10 of the American Academy of Pediatric Dentistry behavior guidance techniques. The type of training was associated with the practitioners' level of comfort using a given technique upon graduation and with the current frequency of technique utilization. Residency type impacted hands-on behavior guidance training, with 39 percent of respondents reporting no intravenous sedation training. The type of practice was associated with the frequency of behavior guidance technique utilization, as was graduation decade. Currently practicing dentists cited legal concerns, parental acceptance to change, and limited resources as perceived obstacles in the incorporation of new techniques. Behavior guidance technique selection and utilization among practicing pediatric dentists was influenced by multiple factors, including advanced education training, residency type, graduation decade, and practice type. Obstacles to the incorporation of previously unused techniques appear to be multifactorial.

  5. Determination of the STIS CCD Gain

    NASA Astrophysics Data System (ADS)

    Riley, Allyssa; Monroe, TalaWanda; Lockwood, Sean

    2016-09-01

    This report summarizes the analysis and absolute gain results of the STIS Cycle 23 special calibration program 14424 that was designed to measure the gain of amplifiers A, C and D at nominal gain settings of 1 and 4 e-/DN. We used the mean-variance technique and the results indicate a <3.5% change in the gain for amplifier D from when it was originally calculated pre-flight. We compared these values to previous measurements from Cycles 17 through 23. This report outlines the observations, methodology, and results of the mean-variance technique.

  6. Paracoccygeal corkscrew approach to ganglion impar injections for tailbone pain.

    PubMed

    Foye, Patrick M; Patel, Shounuck I

    2009-01-01

    A new technique for performing nerve blocks of the ganglion impar (ganglion Walther) is presented. These injections have been reported to relieve coccydynia (tailbone pain), as well as other malignant and nonmalignant pelvic pain syndromes. A variety of techniques have been previously described for blocking this sympathetic nerve ganglion, which is located in the retrorectal space just anterior to the upper coccygeal segments. Prior techniques have included approaches through the anococcygeal ligament, through the sacrococcygeal joint, and through intracoccygeal joint spaces. This article presents a new, paracoccygeal approach whereby the needle is inserted alongside the coccyx and the needle is guided through three discrete steps with a rotating or corkscrew trajectory. Compared with some of the previously published techniques, this paracoccygeal corkscrew approach has multiple potential benefits, including ease of fluoroscopic guidance using the lateral view, ability to easily use a stylet for the spinal needle, and use of a shorter, thinner needle. While no single technique works best for all patients and each technique has potential advantages and disadvantages, this new technique adds to the available options.

  7. Pathological documentation of complete elimination of Barrett's metaplasia following endoscopic multipolar electrocoagulation therapy

    PubMed Central

    Fennerty, M; Corless, C; Sheppard, B; Faigel, D; Lieberman, D; Sampliner, R

    2001-01-01

    The previous paradigm that Barrett's is an irreversible premalignant lesion has recently been challenged by a proliferation of reports documenting elimination of Barrett's by a variety of endoscopic techniques. Whether Barrett's is entirely eliminated is unknown as endoscopic biopsy samples the surface of the epithelium only. Numerous reports document underlying specialised columnar epithelium in many of these trials. Until now there have been no reports of pathological examination of the entire oesophagus as a specimen. This case documents complete elimination of intestinal metaplasia from the oesophagus and supports the biological plausibility of these research techniques.


Keywords: Barrett's oesophagus; endoscopy; multipolar electrocoagulation PMID:11413122

  8. Treatment of Wide-Neck Bifurcation Aneurysm Using "WEB Device Waffle Cone Technique".

    PubMed

    Mihalea, Cristian; Caroff, Jildaz; Rouchaud, Aymeric; Pescariu, Sorin; Moret, Jacques; Spelle, Laurent

    2018-05-01

    The endovascular treatment of wide-neck bifurcation aneurysms can be challenging and often requires the use of adjunctive techniques and devices. We report our first experience of using a waffle-cone technique adapted to the Woven Endoluminal Bridge (WEB) device in a large-neck basilar tip aneurysm, suitable in cases where the use of Y stenting or other techniques is limited due to anatomic restrictions. The procedure was complete, and angiographic occlusion of the aneurysm was achieved 24 hours post treatment, as confirmed by digital subtraction angiography. No complications occurred. The case reported here was not suitable for Y stenting or deployment of the WEB device alone, due to the small caliber of both posterior cerebral arteries and their origin at the neck level. The main advantage of this technique is that both devices have a controlled detachment system and are fully independent. To our knowledge, this technique has not been reported previously and this modality of treatment has never been described in the literature. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. Upon Further Review: V. An Examination of Previous Lightcurve Analysis from the Palmer Divide Observatory

    NASA Astrophysics Data System (ADS)

    Warner, Brian D.

    2011-01-01

    Updated results are given for nine asteroids previously reported from the Palmer Divide Observatory (PDO). The original images were re-measured to obtain new data sets using the latest version of MPO Canopus photometry software, analysis tools, and revised techniques for linking multiple observing runs covering several days to several weeks. Results that were previously not reported or were moderately different were found for 1659 Punkajarju, 1719 Jens, 1987 Kaplan, 2105 Gudy, 2961 Katsurahama, 3285 Ruth Wolfe, 3447 Burckhalter, 7816 Hanoi, and (34817) 2000 SE116. This is one in a series of papers that will examine results obtained during the initial years of the asteroid lightcurve program at PDO.

  10. Technologies for Nondestructive Evaluation of Surfaces and Thin Coatings

    NASA Technical Reports Server (NTRS)

    1999-01-01

    The effort included in this project included several related activities encompassing basic understanding, technological development, customer identification and commercial transfer of several methodologies for nondestructive evaluation of surfaces and thin surface coatings. Consistent with the academic environment, students were involved in the effort working with established investigators to further their training, provide a nucleus of experienced practitioners in the new technologies during their industrial introduction, and utilize their talents for project goals. As will be seen in various portions of the report, some of the effort has led to commercialization. This process has spawned other efforts related to this project which are supported from outside sources. These activities are occupying the efforts of some of the people who were previously supported within this grant and its predecessors. The most advanced of the supported technologies is thermography, for which the previous joint efforts of the investigators and NASA researchers have developed several techniques for extending the utility of straight thermographic inspection by producing methods of interpretation and analysis accessible to automatic image processing with computer data analysis. The effort reported for this technology has been to introduce the techniques to new user communities, who are then be able to add to the effective uses of existing products with only slight development work. In a related development, analysis of a thermal measurement situation in past efforts led to a new insight into the behavior of simple temperature probes. This insight, previously reported to the narrow community in which the particular measurement was made, was reported to the community of generic temperature measurement experts this year. In addition to the propagation of mature thermographic techniques, the development of a thermoelastic imaging system has been an important related development. Part of the work carried out in the effort reported here has been to prepare reports introducing the newly commercially available thermoelastic measurements to the appropriate user communities.

  11. Advances in shock timing experiments on the National Ignition Facility

    NASA Astrophysics Data System (ADS)

    Robey, H. F.; Celliers, P. M.; Moody, J. D.; Sater, J.; Parham, T.; Kozioziemski, B.; Dylla-Spears, R.; Ross, J. S.; LePape, S.; Ralph, J. E.; Hohenberger, M.; Dewald, E. L.; Berzak Hopkins, L.; Kroll, J. J.; Yoxall, B. E.; Hamza, A. V.; Boehly, T. R.; Nikroo, A.; Landen, O. L.; Edwards, M. J.

    2016-03-01

    Recent advances in shock timing experiments and analysis techniques now enable shock measurements to be performed in cryogenic deuterium-tritium (DT) ice layered capsule implosions on the National Ignition Facility (NIF). Previous measurements of shock timing in inertial confinement fusion (ICF) implosions were performed in surrogate targets, where the solid DT ice shell and central DT gas were replaced with a continuous liquid deuterium (D2) fill. These previous experiments pose two surrogacy issues: a material surrogacy due to the difference of species (D2 vs. DT) and densities of the materials used and a geometric surrogacy due to presence of an additional interface (ice/gas) previously absent in the liquid-filled targets. This report presents experimental data and a new analysis method for validating the assumptions underlying this surrogate technique.

  12. GaAsBi/GaAs multi-quantum well LED grown by molecular beam epitaxy using a two-substrate-temperature technique.

    PubMed

    Patil, Pallavi Kisan; Luna, Esperanza; Matsuda, Teruyoshi; Yamada, Kohki; Kamiya, Keisuke; Ishikawa, Fumitaro; Shimomura, Satoshi

    2017-03-10

    We report a GaAs 0.96 Bi 0.04 /GaAs multiple quantum well (MQW) light emitting diode (LED) grown by molecular beam epitaxy using a two-substrate-temperature (TST) technique. In particular, the QWs and the barriers in the intrinsic region were grown at the different temperatures of [Formula: see text] = 350 °C and [Formula: see text] respectively. Investigations of the microstructure using transmission electron microscopy (TEM) reveal homogeneous MQWs free of extended defects. Furthermore, the local determination of the Bi distribution profile across the MQWs region using TEM techniques confirm the uniform Bi distribution, while revealing a slightly chemically graded GaAs-on-GaAsBi interface due to Bi surface segregation. Despite this small broadening, we found that Bi segregation is significantly reduced (up to 18% reduction) compared to previous reports on Bi segregation in GaAsBi/GaAs MQWs. Hence, the TST procedure proves as a very efficient method to reduce Bi segregation and thus increase the quality of the layers and interfaces. These improvements positively reflect in the optical properties. Room temperature photoluminescence and electroluminescence (EL) at 1.23 μm emission wavelength are successfully demonstrated using TST MQWs containing less Bi content than in previous reports. Finally, LED fabricated using the present TST technique show current-voltage (I-V) curves with a forward voltage of 3.3 V at an injection current of 130 mA under 1.0 kA cm -2 current excitation. These results not only demonstrate that TST technique provides optical device quality GaAsBi/GaAs MQWs but highlight the relevance of TST-based growth techniques on the fabrication of future heterostructure devices based on dilute bismides.

  13. GaAsBi/GaAs multi-quantum well LED grown by molecular beam epitaxy using a two-substrate-temperature technique

    NASA Astrophysics Data System (ADS)

    Kisan Patil, Pallavi; Luna, Esperanza; Matsuda, Teruyoshi; Yamada, Kohki; Kamiya, Keisuke; Ishikawa, Fumitaro; Shimomura, Satoshi

    2017-03-01

    We report a GaAs0.96Bi0.04/GaAs multiple quantum well (MQW) light emitting diode (LED) grown by molecular beam epitaxy using a two-substrate-temperature (TST) technique. In particular, the QWs and the barriers in the intrinsic region were grown at the different temperatures of {T}{{GaAsBi}} = 350 °C and {T}{{GaAs}} = 550 ^\\circ {{C}}, respectively. Investigations of the microstructure using transmission electron microscopy (TEM) reveal homogeneous MQWs free of extended defects. Furthermore, the local determination of the Bi distribution profile across the MQWs region using TEM techniques confirm the uniform Bi distribution, while revealing a slightly chemically graded GaAs-on-GaAsBi interface due to Bi surface segregation. Despite this small broadening, we found that Bi segregation is significantly reduced (up to 18% reduction) compared to previous reports on Bi segregation in GaAsBi/GaAs MQWs. Hence, the TST procedure proves as a very efficient method to reduce Bi segregation and thus increase the quality of the layers and interfaces. These improvements positively reflect in the optical properties. Room temperature photoluminescence and electroluminescence (EL) at 1.23 μm emission wavelength are successfully demonstrated using TST MQWs containing less Bi content than in previous reports. Finally, LED fabricated using the present TST technique show current-voltage (I-V) curves with a forward voltage of 3.3 V at an injection current of 130 mA under 1.0 kA cm-2 current excitation. These results not only demonstrate that TST technique provides optical device quality GaAsBi/GaAs MQWs but highlight the relevance of TST-based growth techniques on the fabrication of future heterostructure devices based on dilute bismides.

  14. The effects of implicit encouragement and the putative confession on children's memory reports.

    PubMed

    Cleveland, Kyndra C; Quas, Jodi A; Lyon, Thomas D

    2018-06-01

    The current study tested the effects of two interview techniques on children's report productivity and accuracy following exposure to suggestion: implicit encouragement (backchanneling, use of children's names) and the putative confession (telling children that a suspect "told me everything that happened and wants you to tell the truth"). One hundred and forty-three, 3-8-year-old children participated in a classroom event. One week later, they took part in a highly suggestive conversation about the event and then a mock forensic interview in which the two techniques were experimentally manipulated. Greater use of implicit encouragement led to increases, with age, in children's narrative productivity. Neither technique improved or reduced children's accuracy. No increases in errors about previously suggested information were evident when children received either technique. Implications for the use of these techniques in child forensic interviews are discussed. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Digital enhancement of X-rays for NDT

    NASA Technical Reports Server (NTRS)

    Butterfield, R. L.

    1980-01-01

    Report is "cookbook" for digital processing of industrial X-rays. Computer techniques, previously used primarily in laboratory and developmental research, have been outlined and codified into step by step procedures for enhancing X-ray images. Those involved in nondestructive testing should find report valuable asset, particularly is visual inspection is method currently used to process X-ray images.

  16. The Jigsaw Technique and Self-Efficacy of Vocational Training Students: A Practice Report

    ERIC Educational Resources Information Center

    Darnon, Celine; Buchs, Celine; Desbar, Delphine

    2012-01-01

    Can teenagers' self-efficacy be improved in a short time? Previous research has shown the positive effect of cooperative learning methods, including "jigsaw classrooms" (Aronson and Patnoe, 1997), on various outcomes (e.g., the liking of school, self-esteem, and reduction of prejudices). The present practice report investigated the effects of…

  17. Technical review of SRT-CMA-930058 revalidation studies of Mark 16 experiments: J70

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reed, R.L.

    1993-10-25

    This study is a reperformance of a set of MGBS-TGAL criticality safety code validation calculations previously reported by Clark. The reperformance was needed because the records of the previous calculations could not be located in current APG files and records. As noted by the author, preliminary attempts to reproduce the Clark results by direct modeling in MGBS and TGAL were unsuccessful. Consultation with Clark indicated that the MGBS-TGAL (EXPT) option within the KOKO system should be used to set up the MGBS and TGAL input data records. The results of the study indicate that the technique used by Clark hasmore » been established and that the technique is now documented for future use. File records of the calculations have also been established in APG files. The review was performed per QAP 11--14 of 1Q34. Since the reviewer was involved in developing the procedural technique used for this study, this review can not be considered a fully independent review, but should be considered a verification that the document contains adequate information to allow a new user to perform similar calculations, a verification of the procedure by performing several calculations independently with identical results to the reported results, and a verification of the readability of the report.« less

  18. Nomarski differential interference contrast microscopy for surface slope measurements: an examination of techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hartman, J.S.; Gordon, R.L.; Lessor, D.L.

    1981-08-01

    Alternate measurement and data analysis procedures are discussed and compared for the application of reflective Nomarski differential interference contrast microscopy for the determination of surface slopes. The discussion includes the interpretation of a previously reported iterative procedure using the results of a detailed optical model and the presentation of a new procedure based on measured image intensity extrema. Surface slope determinations from these procedures are presented and compared with results from a previously reported curve fit analysis of image intensity data. The accuracy and advantages of the different procedures are discussed.

  19. Hair transplantation in patients with inadequate head donor supply using nonhead hair: report of 3 cases.

    PubMed

    Umar, Sanusi

    2011-10-01

    Follicular unit extraction is becoming an increasingly popular technique for hair transplantation, as it obviates the linear scarring associated with strip harvesting, and can provide highly presentable results. Using this technique, a few reports have described the small scale use of nonhead hair for head hair transplantation in men with inadequate head hair donor supply. In this report, 3 patients who were severely bald had hair transplanted from the chest, abdomen, legs, shoulders, or beard, as well as the head to achieve full coverage and excellent hairlines. Of the 3 cases, 2 had undergone previously unsuccessful hair transplant surgeries. Approximately 80% to 85% of the transplanted grafts survived. Although hair length and quality, surgery time, and the requirement for improved surgical skills remain challenges when using this technique, the sufficiently good outcomes from these selected candidates suggest that this technique may offer the possibility of restoring even severely bald states to normality in patients who would otherwise not be candidates for traditional hair transplantation surgery.

  20. Chiropractic Name techniques in Canada: a continued look at demographic trends and their impact on issues of jurisprudence

    PubMed Central

    Gleberzon, Brain J

    2002-01-01

    In a previous article, the author reported on the recommendations gathered from student projects between 1996 and 1999 investigating their preferences for including certain chiropractic Name technique systems into the curriculum at the Canadian Memorial Chiropractic College (CMCC). These results were found to be congruent with the professional treatment technique used by Canadian chiropractors. This article reports on the data obtained during the 2000 and 2001 academic years, comparing these results to those previously gathered. In addition, because of the implementation of a new curriculum during this time period, there was unique opportunity to observe whether or not student perceptions differed between those students in the `old' curricular program, and those students in the `new' curricular program. The results gathered indicate that students in both curricular programs show an interest in learning Thompson Terminal Point, Activator Methods, Gonstead, and Active Release Therapy techniques in the core curriculum, as an elective, or during continuing educational programs provided by the college. Students continue to show less interest in learning CranioSacral Therapy, SacroOccipital Technique, Logan Basic, Applied Kinesiology and Chiropractic BioPhysics. Over time, student interest has moved away from Palmer HIO and other upper cervical techniques, and students show a declining interest in being offered instruction in either Network Spinal Analysis or Torque Release Techniques. Since these findings reflect the practice activities of Canadian chiropractors they may have implications not only towards pedagogical decision-making processes at CMCC, but they may also influence professional standards of care.

  1. Improved Estimates of Thermodynamic Parameters

    NASA Technical Reports Server (NTRS)

    Lawson, D. D.

    1982-01-01

    Techniques refined for estimating heat of vaporization and other parameters from molecular structure. Using parabolic equation with three adjustable parameters, heat of vaporization can be used to estimate boiling point, and vice versa. Boiling points and vapor pressures for some nonpolar liquids were estimated by improved method and compared with previously reported values. Technique for estimating thermodynamic parameters should make it easier for engineers to choose among candidate heat-exchange fluids for thermochemical cycles.

  2. Application of imaging techniques to evaluate polishing characteristics of aggregates : final report.

    DOT National Transportation Integrated Search

    2016-12-01

    Previous research conducted at the University of Florida (UF) to investigate the use of the Aggregate Image Measurement System (AIMS) and Micro-Deval (MD) to evaluate frictional performance of aggregates concluded that the current AIMS system cannot ...

  3. DETECTION OF PATHOGENS IN DRINKING WATER (SEER 2)

    EPA Science Inventory

    Project investigators developed a polymerase chain reaction (PCR)-based technique to detect E. coli 0157:H7 cells in environmental samples using previously reported PCR primers for the specific detection of genes involved in biosynthesis of 0157 polysacchari...

  4. Stability of colloidal gold and determination of the Hamaker constant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Demirci, S.; Enuestuen, B.V.; Turkevich, J.

    1978-12-14

    Previous computation of stability factors of colloidal gold from coagulation data was found to be in systematic error due to an underestimation of the particle concentration by electron microscopy. A new experimental technique was developed for determination of this concentration. Stability factors were recalculated from the previous data using the correct concentration. While most of the previously reported conclusions remain unchanged, the absolute rate of fast coagulation is found to agree with that predicted by the theory. A value of the Hamaker constant was determined from the corrected data.

  5. Repair of a complete radial tear in the midbody of the medial meniscus using a novel crisscross suture transtibial tunnel surgical technique: a case report.

    PubMed

    James, Evan W; LaPrade, Christopher M; Feagin, John A; LaPrade, Robert F

    2015-09-01

    Complete radial meniscus tears have been reported to result in deleterious effects in the knee joint if left unrepaired. An emphasis on meniscal preservation is important in order to restore native meniscal function. In this case report, a complete radial tear of the medial meniscus midbody was repaired using a novel crisscross suture transtibial technique. This technique secured the anterior and posterior meniscal horns, which were released from their extruded and scarred position along the capsule, using crisscrossing sutures passed through two transtibial tunnels and secured over a bone bridge on the anterolateral tibia. In addition, the repair was supplemented with the injection of platelet-rich plasma and bone marrow aspirate concentrate to promote the healing of the meniscal tissue. Complete healing on second-look arthroscopy is presented, including in the previously unreported white-white meniscal zone.

  6. The holistic analysis of gamma-ray spectra in instrumental neutron activation analysis

    NASA Astrophysics Data System (ADS)

    Blaauw, Menno

    1994-12-01

    A method for the interpretation of γ-ray spectra as obtained in INAA using linear least squares techniques is described. Results obtained using this technique and the traditional method previously in use at IRI are compared. It is concluded that the method presented performs better with respect to the number of detected elements, the resolution of interferences and the estimation of the accuracies of the reported element concentrations. It is also concluded that the technique is robust enough to obviate the deconvolution of multiplets.

  7. Death by heroin intoxication in a body pusher with an innovative packaging technique: case report and review of the literature.

    PubMed

    Visentin, Sindi; Bevilacqua, Greta; Giraudo, Chiara; Dengo, Caterina; Nalesso, Alessandro; Montisci, Massimo

    2017-11-01

    Death due to mechanical or chemical intoxication of heroin body packers, thanks to the continuous improvement in packaging techniques, are increasingly rare, and almost all the cases reported in the literature refer to drug swallowers. A case of fatal acute heroin intoxication in a body pusher with an unreported packaging technique is presented, and previous deaths due to heroin body packing are reviewed, taking into consideration imaging techniques performed, cause of death, toxicological analysis on biological and non-biological samples, as well as number, position and type of drug packages identified at the dissection of the body. The innovative packaging technique found in the present case, constituted by an external multilayer cellophane casing containing 16 smaller packages of hardened heroin powder, each one covered with cigarette paper and multiple layers of heat-sealed cellophane, was probably used to avoid both chemical complications of package rupture and to create a package with morphological and radiological features different from those reported by previous studies. Drug dealers, in fact, are continually looking for packaging methods that, besides being safer, minimize the risk of detection at the radiological examinations performed, thus increasing the number of false negative findings. The identification of new types of package is therefore important, in order to identify packages that do not have the typical radiological signs, both in order to protect the patient's health and to avoid the non-recognition of a drug carrier. Despite the presence of multilayer composition of both the smaller and the bigger external coverage, these new types of package did not guarantee the greater safety of the drug dealer. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Manual therapy intervention for a patient with a total hip arthroplasty revision.

    PubMed

    Howard, Paul D; Levitsky, Beth

    2007-12-01

    Case report. A 73-year-old active woman with a total hip arthroplasty, who later had revision surgery, developed left hip and buttock pain 2 years after the revision surgery, subsequent to lifting her foot while seated. This movement was performed so that her spouse could assist her in putting on her sock and shoe. During the first physical therapy session, the patient exhibited a forward-flexed trunk posture and difficulty weight bearing on the involved lower limb. The patient was successfully treated with manual therapy techniques and a home exercise program. The manual therapy techniques included long-axis hip distraction, lateral hip distraction, posterior-to-anterior hip joint mobilization, and a contract-relax proprioceptive neuromuscular facilitation technique. The patient's home program consisted of long-axis hip distraction, performed by her spouse, and standing lower limb pendular movements into flexion and extension. Pain scale ratings, posture and gait observations, strength, range of motion, and return to functional activities served as outcome measures. After 1 physical therapy visit, in which manual therapy techniques were utilized, the patient had a significant decrease in hip symptoms. The patient and spouse were compliant with the home exercise program and continued with physical therapy for 3 more visits, and the patient ultimately became symptom free. The patient returned to all previous activities, including household chores, cooking, and a walking program. The patient was contacted at 6 months, 1 year, and 4 years, and reported no recurrences of hip or buttock symptoms. Manual therapy techniques and home exercises described in this case report were apparently effective in eliminating symptoms and returning this patient, who had total hip arthroplasty and revision surgery 2 years earlier, to all previous functional activities after a dressing incident produced hip and buttock symptoms.

  9. Investigating the Similarities and Differences between Practitioners of Second and Third Wave Cognitive-Behavioral Therapies

    PubMed Central

    Brown, Lily A.; Gaudiano, Brandon A.; Miller, Ivan W.

    2013-01-01

    There has been much discussion in the literature recently regarding the conceptual and techniual differences between so-called second (e.g., Beckian cognitive therapy) and third “wave” (e.g., acceptance and commitment therapy) behavior therapies. Previous research has not addressed the potential similarities and differences among the practitioners of these types of approaches. The current study examined possible differences in the characteristics of second wave (n=55) and third wave cognitive-behavioral therapists (n=33) using an internet-based survey. There were differences found at the technique level between the two groups. As expected, third wave therapists reported greater use of mindfulness/acceptance techniques. Also, third wave therapists reported greater use of exposure techniques and second wave therapists reported greater use of cognitive restructuring and relaxation techniques. In general, third wave clinicians were more eclectic at the technique level, and demonstrated significantly greater use of family systems techniques, existential/humanistic techniques, and the total number of techniques used. No significant differences were found on the attitudinal measures administered, including reliance on an intuitive thinking style, acceptance of complementary and alternative therapies and related health beliefs, or most attitudes toward evidence-based practices. We did not identify many differences between second wave and third wave therapists other than in terms of the techniques they employ. The clinical and research implications for these findings are discussed. PMID:21324946

  10. Access to destinations : annual accessibility measure for the Twin Cities Metropolitan Region.

    DOT National Transportation Integrated Search

    2012-11-01

    This report summarizes previous phases of the Access to Destinations project and applies the techniques developed : over the course of the project to conduct an evaluation of accessibility in the Twin Cities metropolitan region for : 2010. It describ...

  11. Group decision-making techniques for natural resource management applications

    USGS Publications Warehouse

    Coughlan, Beth A.K.; Armour, Carl L.

    1992-01-01

    This report is an introduction to decision analysis and problem-solving techniques for professionals in natural resource management. Although these managers are often called upon to make complex decisions, their training in the natural sciences seldom provides exposure to the decision-making tools developed in management science. Our purpose is to being to fill this gap. We present a general analysis of the pitfalls of group problem solving, and suggestions for improved interactions followed by the specific techniques. Selected techniques are illustrated. The material is easy to understand and apply without previous training or excessive study and is applicable to natural resource management issues.

  12. Deep brain stimulation with a pre-existing cochlear implant: Surgical technique and outcome.

    PubMed

    Eddelman, Daniel; Wewel, Joshua; Wiet, R Mark; Metman, Leo V; Sani, Sepehr

    2017-01-01

    Patients with previously implanted cranial devices pose a special challenge in deep brain stimulation (DBS) surgery. We report the implantation of bilateral DBS leads in a patient with a cochlear implant. Technical nuances and long-term interdevice functionality are presented. A 70-year-old patient with advancing Parkinson's disease and a previously placed cochlear implant for sensorineural hearing loss was referred for placement of bilateral DBS in the subthalamic nucleus (STN). Prior to DBS, the patient underwent surgical removal of the subgaleal cochlear magnet, followed by stereotactic MRI, frame placement, stereotactic computed tomography (CT), and merging of imaging studies. This technique allowed for successful computational merging, MRI-guided targeting, and lead implantation with acceptable accuracy. Formal testing and programming of both the devices were successful without electrical interference. Successful DBS implantation with high resolution MRI-guided targeting is technically feasible in patients with previously implanted cochlear implants by following proper precautions.

  13. Measurement of sub-parts-per-billion levels of carbonyl compounds in marine air by a simple cartridge trapping procedure followed by liquid chromatography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xianliang, Zhou; Mopper, K.

    1990-10-01

    Carbonyl compounds in clean marine air were trapped onto 2,4-dinitrophenylhydrazine- (DNPH-) coated cartridges, and their hydrazone derivatives were separated by HPLC and detected by UV absorbance. More than 20 carbonyl compounds were isolated from marine air with >92% collection efficiency. The technique employs a highly effective reagent purification procedure, which results in much lower blanks compared to previously reported trapping techniques for carbonyl compounds. Blanks were routinely <0.07 ppb for formaldehyde and acetone and <0.02 ppb for the others. Humidity and reactive gases have no detectable effect on collection efficiencies. Carbonyl-DNPH derivatives eluted from the cartridges are stable in acetonitrilemore » for at least 2 weeks, which facilitates field studies. Several previously undetected unknown carbonyl compounds were found in marine air by this technique. Typical results for open ocean and coastal marine air are shown.« less

  14. An Overview of the Percutaneous Antibiotic Delivery Technique for Osteomyelitis Treatment and a Case Study of Calcaneal Osteomyelitis.

    PubMed

    Karr, Jeffrey C

    2017-11-01

    A percutaneous antibiotic delivery technique (PAD-T) used for the adjunctive management of osteomyelitis is presented. This surgical technique incorporates a calcium sulfate and hydroxyapatite (calcium phosphate) bone void filler acting as a carrier vehicle with either an antibiotic or an antifungal medicine, delivering this combination directly into the area of osteomyelitis. The benefit of the PAD-T is reviewed with a case presentation of a successfully treated calcaneal osteomyelitis. No previously reported PAD-T using a simple bone cortex incision in the adjunctive treatment of osteomyelitis has been reported. The PAD-T safely and effectively uses a calcium sulfate and hydroxyapatite bone void filler carrier vehicle to deliver either an antibiotic or an antifungal medicine directly into the area of osteomyelitis.

  15. Gonioscopy-assisted Transluminal Trabeculotomy (GATT): Thermal Suture Modification With a Dye-stained Rounded Tip.

    PubMed

    Grover, Davinder S; Fellman, Ronald L

    2016-06-01

    To describe a novel technique for thermally marking the tip of a suture, in preparation for a gonioscopy-assisted transluminal trabeculotomy. One patient was used as an example for this technique. Technique report. The authors introduce a modification of a novel surgical procedure (GATT) in which a suture is marked and thermally blunted allowing a proper visualization while performing an ab interno, minimally invasive, circumferential 360-degree suture trabeculotomy. The authors have previously reported on the GATT surgery with the use of an illuminated microcatheter, which allowed for visualization of the tip of the catheter as it circumnavigated Schlemm canal. This modification allows for similar visualization of the tip of the suture, however, is much more cost-effective while still maintaining similar safety.

  16. Utilization of thermoluminescent dosimetry in total skin electron beam radiotherapy of mycosis fungoides.

    PubMed

    Antolak, J A; Cundiff, J H; Ha, C S

    1998-01-01

    The purpose of this report is to discuss the utilization of thermoluminescent dosimetry (TLD) in total skin electron beam (TSEB) radiotherapy to: (a) compare patient dose distributions for similar techniques on different machines, (b) confirm beam calibration and monitor unit calculations, (c) provide data for making clinical decisions, and (d) study reasons for variations in individual dose readings. We report dosimetric results for 72 cases of mycosis fungoides, using similar irradiation techniques on two different linear accelerators. All patients were treated using a modified Stanford 6-field technique. In vivo TLD was done on all patients, and the data for all patients treated on both machines was collected into a database for analysis. Means and standard deviations (SDs) were computed for all locations. Scatter plots of doses vs. height, weight, and obesity index were generated, and correlation coefficients with these variables were computed. The TLD results show that our current TSEB implementation is dosimetrically equivalent to the previous implementation, and that our beam calibration technique and monitor unit calculation is accurate. Correlations with obesity index were significant at several sites. Individual TLD results allow us to customize the boost treatment for each patient, in addition to revealing patient positioning problems and/or systematic variations in dose caused by patient variability. The data agree well with previously published TLD results for similar TSEB techniques. TLD is an important part of the treatment planning and quality assurance programs for TSEB, and routine use of TLD measurements for TSEB is recommended.

  17. Genetic and epigenetic instability of stem cells.

    PubMed

    Rajamani, Karthyayani; Li, Yuan-Sheng; Hsieh, Dean-Kuo; Lin, Shinn-Zong; Harn, Horng-Jyh; Chiou, Tzyy-Wen

    2014-01-01

    Recently, research on stem cells has been receiving an increasing amount of attention, both for its advantages and disadvantages. Genetic and epigenetic instabilities among stem cells have been a recurring obstacle to progress in regenerative medicine using stem cells. Various reports have stated that these instabilities can transform stem cells when transferred in vivo and thus have the potential to develop tumors. Previous research has shown that various extrinsic and intrinsic factors can contribute to the stability of stem cells. The extrinsic factors include growth supplements, growth factors, oxygen tension, passage technique, and cryopreservation. Controlling these factors based on previous reports may assist researchers in developing strategies for the production and clinical application of "safe" stem cells. On the other hand, the intrinsic factors can be unpredictable and uncontrollable; therefore, to ensure the successful use of stem cells in regenerative medicine, it is imperative to develop and implement appropriate strategies and technique for culturing stem cells and to confirm the genetic and epigenetic safety of these stem cells before employing them in clinical trials.

  18. Advanced liner-cooling techniques for gas turbine combustors

    NASA Technical Reports Server (NTRS)

    Norgren, C. T.; Riddlebaugh, S. M.

    1985-01-01

    Component research for advanced small gas turbine engines is currently underway at the NASA Lewis Research Center. As part of this program, a basic reverse-flow combustor geometry was being maintained while different advanced liner wall cooling techniques were investigated. Performance and liner cooling effectiveness of the experimental combustor configuration featuring counter-flow film-cooled panels is presented and compared with two previously reported combustors featuring: splash film-cooled liner walls; and transpiration cooled liner walls (Lamilloy).

  19. Purification of swine haptoglobin by affinity chromatography.

    PubMed Central

    Eurell, T E; Hall, W F; Bane, D P

    1990-01-01

    A globin-agarose affinity chromatography technique was used to purify swine haptoglobin. This technique provides a highly specific, single-step purification method without the contamination of extraneous serum proteins reported by previous studies. Complex formation between the haptoglobin isolate and swine hemoglobin confirmed that biological activity was maintained during the purification process. Immunoelectrophoretic and Ouchterlony immunodiffusion methods revealed that the swine haptoglobin isolate cross-reacted with polyvalent antisera against human haptoglobin. Images Fig. 2. Fig. 3. PMID:2123414

  20. Mapping land cover from satellite images: A basic, low cost approach

    NASA Technical Reports Server (NTRS)

    Elifrits, C. D.; Barney, T. W.; Barr, D. J.; Johannsen, C. J.

    1978-01-01

    Simple, inexpensive methodologies developed for mapping general land cover and land use categories from LANDSAT images are reported. One methodology, a stepwise, interpretive, direct tracing technique was developed through working with university students from different disciplines with no previous experience in satellite image interpretation. The technique results in maps that are very accurate in relation to actual land cover and relative to the small investment in skill, time, and money needed to produce the products.

  1. NMR studies of multiphase flows II

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Altobelli, S.A.; Caprihan, A.; Fukushima, E.

    NMR techniques for measurements of spatial distribution of material phase, velocity and velocity fluctuation are being developed and refined. Versions of these techniques which provide time average liquid fraction and fluid phase velocity have been applied to several concentrated suspension systems which will not be discussed extensively here. Technical developments required to further extend the use of NMR to the multi-phase flow arena and to provide measurements of previously unobtainable parameters are the focus of this report.

  2. An Axial-Torsional, Thermomechanical Fatigue Testing Technique

    NASA Technical Reports Server (NTRS)

    Kalluri, Sreeramesh; Bonacuse, Peter J.

    1995-01-01

    A technique for conducting strain-controlled, thermomechanical, axial-torsional fatigue tests on thin-walled tubular specimens was developed. Three waveforms of loading, namely, the axial strain waveform, the engineering shear strain waveform, and the temperature waveform were required in these tests. The phasing relationships between the mechanical strain waveforms and the temperature and axial strain waveforms were used to define a set of four axial-torsional, thermomechanical fatigue (AT-TMF) tests. Real-time test control (3 channels) and data acquisition (a minimum of 7 channels) were performed with a software program written in C language and executed on a personal computer. The AT-TMF testing technique was used to investigate the axial-torsional thermomechanical fatigue behavior of a cobalt-base superalloy, Haynes 188. The maximum and minimum temperatures selected for the AT-TMF tests were 760 and 316 C, respectively. Details of the testing system, calibration of the dynamic temperature profile of the thin-walled tubular specimen, thermal strain compensation technique, and test control and data acquisition schemes, are reported. The isothermal, axial, torsional, and in- and out-of-phase axial-torsional fatigue behaviors of Haynes 188 at 316 and 760 C were characterized in previous investigations. The cyclic deformation and fatigue behaviors of Haynes 188 in AT-TMF tests are compared to the previously reported isothermal axial-torsional behavior of this superalloy at the maximum and minimum temperatures.

  3. Karolinska prostatectomy: a robot-assisted laparoscopic radical prostatectomy technique.

    PubMed

    Nilsson, Andreas E; Carlsson, Stefan; Laven, Brett A; Wiklund, N Peter

    2006-01-01

    The last decade has witnessed an increasing trend towards minimally invasive management of prostate cancer, including laparoscopic and, more recently, robot-assisted laparoscopic prostatectomy. Several different laparoscopic approaches have been continuously developed during the last 5 years and it is still unclear which technique yields the best outcome. We present our current technique of robot-assisted laparoscopic radical prostatectomy. The technique described has evolved during the course of >400 robotic prostatectomies performed by the robotic team since the robot-assisted laparoscopic radical prostatectomy program was introduced at Karolinska University Hospital in January 2002. Our procedure comprises several modifications of previously reported ones, and we utilize fewer robotic instruments to reduce costs. An extended posterior dissection is performed to aid in the bladder neck-sparing dissection. In nerve-sparing procedures the vesicles are divided to avoid damage to the erectile nerves. In order to preserve the apical anatomy the dorsal venous complex is incised sharply and is first over-sewn after the apical dissection is completed. Our technique enables a more fluent dissection than previously described robotic techniques. Minimizing changes of instruments and the camera not only cuts costs but also reduces inefficient operating maneuvers, such as switching between 30 degrees and 0 degrees lenses during the procedure. We present a technique which in our hands has achieved excellent functional and oncological results.

  4. What about the Misgav-Ladach surgical technique in patients with previous cesarean sections?

    PubMed

    Bolze, Pierre-Adrien; Massoud, Mona; Gaucherand, Pascal; Doret, Muriel

    2013-03-01

    The Misgav-Ladach technique is recommended worldwide to perform cesarean sections but there is no consensus about the appropriate technique to use in patients with previous cesarean sections. This study evaluated the feasibility of the Misgav-Ladach technique in patients with previous cesarean sections. This prospective cohort study included all women undergoing cesarean section after 36 weeks of gestation over a 5-month period, with the Misgav-Ladach technique as first choice, whatever the previous number of cesarean sections. Among the 204 patients included, the Misgav-Ladach technique was successful in 100%, 80%, and 65.6% of patients with no, one, and multiple previous cesarean sections, respectively. When successful, the Misgav-Ladach technique was associated with a shorter incision to birth interval in patients with no previous cesarean section compared with patients with one or multiple previous cesarean sections. Anterior rectus aponeurosis fibrosis and severe peritoneal adherences were the two main reasons explaining the Misgav-Ladach technique failure. The Misgav-Ladach technique is possible in over three-fourths of patients with previous cesarean sections with a slight increase in incision to birth interval compared with patients without previous cesarean section. Further studies comparing the Misgav-Ladach and the Pfannenstiel techniques in women with previous cesarean should be done. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  5. Single Crystal Growth of URu 2Si 2 by the Modified Bridgman Technique

    DOE PAGES

    Gallagher, Andrew; Nelson, William L.; Chen, Kuan Wen; ...

    2016-10-02

    We describe a modified Bridgman growth technique to produce single crystals of the strongly correlated electron material URu 2Si 2 and its nonmagnetic analogue ThRu 2Si 2. Bulk thermodynamic and electrical transport measurements show that the properties of crystals produced in this way are comparable to those previously synthesized using the Czochralski or conventional molten metal flux growth techniques. For the specimens reported here, we find residual resistivity ratios RRR = ρ 300K / ρ 0 as large as 116 and 187 for URu 2Si 2 and ThRu 2Si 2, respectively.

  6. Percutaneous treatment of complex biliary stone disease using endourological technique and literature review

    PubMed Central

    Korkes, Fernando; Carneiro, Ariê; Nasser, Felipe; Affonso, Breno Boueri; Galastri, Francisco Leonardo; de Oliveira, Marcos Belotto; Macedo, Antônio Luiz de Vasconcellos

    2015-01-01

    Most biliary stone diseases need to be treated surgically. However, in special cases that traditional biliary tract endoscopic access is not allowed, a multidisciplinary approach using hybrid technique with urologic instrumental constitute a treatment option. We report a case of a patient with complex intrahepatic stones who previously underwent unsuccessful conventional approaches, and who symptoms resolved after treatment with hybrid technique using an endourologic technology. We conducted an extensive literature review until October 2012 of manuscripts indexed in PubMed on the treatment of complex gallstones with hybrid technique. The multidisciplinary approach with hybrid technique using endourologic instrumental represents a safe and effective treatment option for patients with complex biliary stone who cannot conduct treatment with conventional methods. PMID:26061073

  7. Optimization of the tungsten oxide technique for measurement of atmospheric ammonia

    NASA Technical Reports Server (NTRS)

    Brown, Kenneth G.

    1987-01-01

    Hollow tubes coated with tungstic acid have been shown to be of value in the determination of ammonia and nitric acid in ambient air. Practical application of this technique was demonstrated utilizing an automated sampling system for in-flight collection and analysis of atmospheric samples. Due to time constraints these previous measurements were performed on tubes that had not been well characterized in the laboratory. As a result the experimental precision could not be accurately estimated. Since the technique was being compared to other techniques for measuring these compounds, it became necessary to perform laboratory tests which would establish the reliability of the technique. This report is a summary of these laboratory experiments as they are applied to the determination of ambient ammonia concentration.

  8. Advice from the Trenches: Experienced Educators Discuss Distance Learning

    ERIC Educational Resources Information Center

    Lawhon, Tommie; Ennis-Cole, Demetria

    2005-01-01

    Planning, managing, and maintaining distance learning courses present challenges and opportunities for faculty that require shifts in teaching techniques and management. Interviews with experienced professors, published reports, and primary data assist in identifying reasons for the successes and failures of previous e-learning efforts while…

  9. Surgical repair of an aberrant splenic artery aneurysm: report of a case.

    PubMed

    Illuminati, Giulio; LaMuraglia, Glenn; Nigri, Giuseppe; Vietri, Francesco

    2007-03-01

    Aneurysms of the splenic artery are the most common splanchnic aneurysms. Aneurysms of a splenic artery with an anomalous origin from the superior mesenteric artery are however rare, with eight previously reported cases. Their indications for treatment are superposable to those of aneurysms affecting an orthotopic artery. Methods of treatment of this condition include endovascular, minimally invasive techniques and surgical resection. We report one more case of aneurysm of an aberrant splenic artery, treated with surgical resection, and preservation of the spleen.

  10. Space Shuttle propulsion parameter estimation using optimal estimation techniques

    NASA Technical Reports Server (NTRS)

    1983-01-01

    This fourth monthly progress report again contains corrections and additions to the previously submitted reports. The additions include a simplified SRB model that is directly incorporated into the estimation algorithm and provides the required partial derivatives. The resulting partial derivatives are analytical rather than numerical as would be the case using the SOBER routines. The filter and smoother routine developments have continued. These routines are being checked out.

  11. Simultaneous bilateral robotic partial nephrectomy: Case report and critical evaluation of the technique.

    PubMed

    Giberti, Claudio; Gallo, Fabrizio; Schenone, Maurizio; Cortese, Pierluigi

    2014-06-16

    We report our first simultaneous bilateral robot assisted partial nephrectomy (RAPN) in order to show and critically discuss the feasibility of this procedure. Materials and methods A 69-year-old male patient visited our department due to incidental finding of bilateral mesorenal small masses (2.5 cm on the right and 3.5 cm on the left) suspicious for malignancy. We started from the right side with patient in flank position. Port placement: 12-mm periumbilical camera port, two 8-mm robotic ports in wide ''V''configuration, additional 12 mm assistant port on the midline between the umbilicus and symphysis pubis. A right unclamping RAPN with sliding clip renorrhaphy was performed. The trocars were removed and the robot undocked. Without interrupting the anesthesiological procedures, the patient was reported in supine position and, after 180 degrees rotation of the surgical bed, was newly placed in contralateral flank position. Using both the previous periumbilical and midline ports, two other 8-mm robotic trocars were placed. The robot was then redocked and RAPN was also performed on the left side using the same previously reported technique. Results Total time: 285 min. Estimated blood losses: 150 cc. Postoperative period: uneventful. Pathological examination: bilateral renal cell carcinoma, negative surgical margins. Conclusions Our experience was encouraging and confirmed the feasibility and safety of this procedure. The planning of our technique was time and cost effective with cosmetic benefit for the patient. However, we think that an appropriate selection of the patients and a skill in robotic renal surgery are advisable before approaching this type of surgery.

  12. A Rigorous Attempt to Verify Interstellar Glycine

    NASA Technical Reports Server (NTRS)

    Snyder, L. E.; Lovas, F. J.; Hollis, J. M.; Friedel, D. N.; Jewell, P. R.; Remijan, A.; Ilyushin, V. V.; Alekseev, E. A.; Dyubko, S. F.

    2004-01-01

    In 2003, Kuan, Charnley, and co-workers reported the detection of interstellar glycine (NH2CH2COOH) based on observations of 27 lines in 19 different spectral bands in one or more of the sources Sgr BP(N-LMH), Orion KL, and W51 e1/e2. They supported their detection report with rotational temperature diagrams for all three sources. In this paper, we present essential criteria which can be used in a straightforward analysis technique to confirm the identity of an interstellar asymmetric rotor such as glycine. We use new laboratory measurements of glycine as a basis for applying this analysis technique, both to our previously unpublished 12 m telescope data and to the previously published SEST data of Nummelin and colleagues. We conclude that key lines necessary for an interstellar glycine identification have not yet been found. We identify several common molecular candidates that should be examined further as more likely carriers of the lines reported as glycine. Finally, we illustrate that rotational temperature diagrams used without the support of correct spectroscopic assignments are not a reliable tool for the identification of interstellar molecules. Subject headings: ISM: abundances - ISM: clouds - ISM: individual (Sagittarius B2[N-

  13. Nonlinear system identification technique validation

    NASA Astrophysics Data System (ADS)

    Rudko, M.; Bussgang, J. J.

    1982-01-01

    This final technical report describes the results obtained by SIGNATRON, Inc. of Lexington MA on Air Force Contract F30602-80-C-0104 for Rome Air Development Center. The objective of this effort is to develop a technique for identifying system response of nonlinear circuits by measurements of output response to known inputs. The report describes results of a study into the system identification technique based on the pencil-of-function method previously explored by Jain (1974) and Ewen (1979). The procedure identified roles of the linear response and is intended as a first step in nonlinear response and is intended as a first step in nonlinear circuit identification. There are serious implementation problems associated with the original approach such as loss of accuracy due to repeated integrations, lack of good measures of accuracy and computational iteration to identify the number of poles.

  14. Fungal Keratitis Due to Beauveria bassiana in a Contact Lenses Wearer and Review of Published Reports.

    PubMed

    Lara Oya, Ana; Medialdea Hurtado, María Eloisa; Rojo Martín, María Dolores; Aguilera Pérez, Antonia; Alastruey-Izquierdo, Ana; Miranda Casas, Consuelo; Rubio Prats, Marina; Medialdea Marcos, Santiago; Navarro Marí, José María

    2016-10-01

    Fungal keratitis is a severe ocular infection that primarily affects subjects engaged in outdoor activities. Risk factors include allergic conjunctivitis, previous eye surgery, previous treatment with wide-spectrum antimicrobial agents and corticosteroids and using contact lenses. Corneal infection is usually secondary to trauma involving organic material, which is often the only predisposing factor. Early diagnosis based on clinical examination and microbiological investigation (microscopy, cultures and molecular techniques) is crucial to selecting the appropriate antifungal therapy and prevent progression. We report the case of a patient with keratitis due to Beauveria bassiana, an opportunistic and entomopathogenic filamentous fungus that is used as a biological insecticide and which is a rare cause of corneal infection. We review previous cases reports of B. bassiana keratitis published and its main features to compare with our case, a female occasional agriculture worker who had not suffered any trauma involving organic material. The patient received topical and oral antifungal therapy and debridement surgery, with a satisfactory outcome.

  15. Color surface-flow visualization of fin-generated shock wave boundary-layer interactions

    NASA Technical Reports Server (NTRS)

    Lu, F. K.; Settles, G. S.

    1990-01-01

    Kerosene-lampblack mixtures with addition of a ground colored chalk were used in an experiment on visualizing surface flows of swept shock boundary-layer interactions. The results show that contrasting colors intensify the visualization of different regions of the interaction surface, and help the eye in following the fine streaks to locate the upstream influence. The study confirms observations of the separation occurring at shock strength below accepted values. The superiority of the reported technique over the previous monochrome technique is demonstrated.

  16. Practical uncertainty reduction and quantification in shock physics measurements

    DOE PAGES

    Akin, M. C.; Nguyen, J. H.

    2015-04-20

    We report the development of a simple error analysis sampling method for identifying intersections and inflection points to reduce total uncertainty in experimental data. This technique was used to reduce uncertainties in sound speed measurements by 80% over conventional methods. Here, we focused on its impact on a previously published set of Mo sound speed data and possible implications for phase transition and geophysical studies. However, this technique's application can be extended to a wide range of experimental data.

  17. Color surface-flow visualization of fin-generated shock wave boundary-layer interactions

    NASA Astrophysics Data System (ADS)

    Lu, F. K.; Settles, G. S.

    1990-03-01

    Kerosene-lampblack mixtures with addition of a ground colored chalk were used in an experiment on visualizing surface flows of swept shock boundary-layer interactions. The results show that contrasting colors intensify the visualization of different regions of the interaction surface, and help the eye in following the fine streaks to locate the upstream influence. The study confirms observations of the separation occurring at shock strength below accepted values. The superiority of the reported technique over the previous monochrome technique is demonstrated.

  18. New technique for treating pseudocyst of the auricle.

    PubMed

    Zhu, L X; Wang, X Y

    1990-01-01

    Although pseudocyst of the auricle is a common disease in China, its cause and mechanism are still not clear. Several methods of treatment have been advocated: repeated aspirations combined with physiotherapy, and incision and drainage with contour pressure dressing, magnetotherapy etc. In recent years, a new technique with a drainage tube inserted into the pseudocyst using a guide needle has been used in our hospital in the treatment of this condition. We report 45 cases treated by this method, none of whom had the condition previously.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carla J. Miller

    This report provides a summary of the literature review that was performed and based on previous work performed at the Idaho National Laboratory studying the Three Mile Island 2 (TMI-2) nuclear reactor accident, specifically the melted fuel debris. The purpose of the literature review was to document prior published work that supports the feasibility of the analytical techniques that were developed to provide quantitative results of the make-up of the fuel and reactor component debris located inside and outside the containment. The quantitative analysis provides a technique to perform nuclear fuel accountancy measurements

  20. Electropyroelectric technique: A methodology free of fitting procedures for thermal effusivity determination in liquids.

    PubMed

    Ivanov, R; Marin, E; Villa, J; Gonzalez, E; Rodríguez, C I; Olvera, J E

    2015-06-01

    This paper describes an alternative methodology to determine the thermal effusivity of a liquid sample using the recently proposed electropyroelectric technique, without fitting the experimental data with a theoretical model and without having to know the pyroelectric sensor related parameters, as in most previous reported approaches. The method is not absolute, because a reference liquid with known thermal properties is needed. Experiments have been performed that demonstrate the high reliability and accuracy of the method with measurement uncertainties smaller than 3%.

  1. Use of Cryoablation and Osteoplasty Reinforced with Kirschner Wires in the Treatment of Femoral Metastasis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abdel-Aal, Ahmed Kamel, E-mail: akamel@uabmc.edu; Underwood, Edgar S.; Saddekni, Souheil

    2012-10-15

    Purpose: We report the case of a 43-year-old man with metastatic breast carcinoma to the proximal right femur resulting in severe painful pathological fracture. The patient experienced severe pain despite large doses of analgesia, resulting in impaired functionality and quality of life. The patient had significant comorbidities, making him a high surgical risk. Materials and Methods: The patient was treated with cryoablation and osteoplasty, followed by a novel technique consisting of osteoplasty reinforced with bone marrow Kirschner wires (K-wires) which will be described in details in this report. Results: The patient reported significant pain relief after the procedure, and gainedmore » right lower extremity functionality, as compared to total immobility before the procedure. Conclusion: Our technique offers an alternative feasible treatment for patients at high surgical risk with pathological fractures in weight-bearing bones, in which osteoplasty alone has a high risk of cement leakage, inadequate fracture reduction, and early refracture. To our knowledge, our technique has not been previously described.« less

  2. CYCLOPS-3 System Research.

    ERIC Educational Resources Information Center

    Marill, Thomas; And Others

    The aim of the CYCLOPS Project research is the development of techniques for allowing computers to perform visual scene analysis, pre-processing of visual imagery, and perceptual learning. Work on scene analysis and learning has previously been described. The present report deals with research on pre-processing and with further work on scene…

  3. National Database Structure for Life Cycle Performance Assessment of Water and Wastewater Rehabilitation Technologies (Retrospective Evaluation)

    EPA Science Inventory

    This report builds upon a previous pilot study to document the in-service performance of trenchless pipe rehabilitation techniques. The use of pipe rehabilitation and trenchless pipe replacement technologies has increased over the past 30 to 40 years and represents an increasing...

  4. Evaluation of techniques for ocular measurement as an index of fatigue and as the basis for alertness management

    DOT National Transportation Integrated Search

    1998-04-01

    This final report establishes the scientific validity of the ocular measure "Perclose" as a generally useful and reliable index of lapses in visual attention, i.e. the percentage of eyelid closure over the pupil. Perclose was previously specified as ...

  5. Initial experience with custom-fit total knee replacement: intra-operative events and long-leg coronal alignment.

    PubMed

    Spencer, Brian A; Mont, Michael A; McGrath, Mike S; Boyd, Bradley; Mitrick, Michael F

    2009-12-01

    New technology using magnetic resonance imaging (MRI) allows the surgeon to place total knee replacement components into each patient's pre-arthritic natural alignment. This study evaluated the initial intra-operative experience using this technique. Twenty-one patients had a sagittal MRI of their arthritic knee to determine component placement for a total knee replacement. Cutting guides were machined to control all intra-operative cuts. Intra-operative events were recorded and these knees were compared to a matching cohort of the senior surgeon's previous 30 conventional total knee replacements. Post-operative scanograms were obtained from each patient and coronal alignment was compared to previous studies using conventional and computer-assisted techniques. There were no intra-operative or acute post-operative complications. There were no differences in blood loss and there was a mean decrease in operative time of 14% compared to a cohort of patients with conventional knee replacements. The average deviation from the mechanical axis was 1.2 degrees of varus, which was comparable to previously reported conventional and computer-assisted techniques. Custom-fit total knee replacement appeared to be a safe procedure for uncomplicated cases of osteoarthritis.

  6. Anterior transarticular C1-C2 fixation with contralateral screw insertion: a report of two cases and technical note.

    PubMed

    Lvov, Ivan; Grin, Andrey; Kaykov, Aleksandr; Smirnov, Vladimir; Krylov, Vladimir

    2017-08-08

    Anterior transarticular fixation of the C1-C2 vertebrae is a well-known technique that involves screw insertion through the body of the C2 vertebra into the lateral masses of the atlas through an anterior transcervical approach. Meanwhile, contralateral screw insertion has been previously described only in anatomical studies. We describe two case reports of the clinical application of this new technique. In Case 1, the patient was diagnosed with an unstable C1 fracture. The clinical features of the case did not allow for any type of posterior atlantoaxial fusion, Halo immobilization, or routine anterior fixation using the Reindl and Koller techniques. The possible manner of screw insertion into the anterior third of the right lateral mass was via a contralateral trajectory, which was performed in this case. Case 2 involved a patient with neglected posteriorly dislocated dens fracture who could not lie in the prone position due to concomitant cardiac pathology. Reduction of atlantoaxial dislocation was insufficient, even after scar tissue resection at the fracture, while transdental fusion was not possible. Considering the success of the previous case, atlantoaxial fixation was performed through the small approach, using the Reindl technique and contralateral screw insertion. These two cases demonstrate the potential of anterior transarticular fixation of C1-C2 vertebrae in cases where posterior atlantoaxial fusion is not achievable. This type of fixation can be performed through a single approach if one screw is inserted using the Reindl technique and another is inserted via a contralateral trajectory.

  7. Whole-rock analyses of core samples from the 1988 drilling of Kilauea Iki lava lake, Hawaii

    USGS Publications Warehouse

    Helz, Rosalind Tuthill; Taggart, Joseph E.

    2010-01-01

    This report presents and evaluates 64 major-element analyses of previously unanalyzed Kilauea Iki drill core, plus three samples from the 1959 and 1960 eruptions of Kilauea, obtained by X-ray fluorescence (XRF) analysis during the period 1992 to 1995. All earlier major-element analyses of Kilauea Iki core, obtained by classical (gravimetric) analysis, were reported and evaluated in Helz and others (1994). In order to assess how well the newer data compare with this earlier suite of analyses, a subset of 24 samples, which had been analyzed by classical analysis, was reanalyzed using the XRF technique; those results are presented and evaluated in this report also. The XRF analyses have not been published previously. This report also provides an overview of how the chemical variations observed in these new data fit in with the chemical zonation patterns and petrologic processes inferred in earlier studies of Kilauea Iki.

  8. All-optical technique for measuring thermal properties of materials at static high pressure

    NASA Astrophysics Data System (ADS)

    Pangilinan, G. I.; Ladouceur, H. D.; Russell, T. P.

    2000-10-01

    The development and implementation of an all-optical technique for measuring thermal transport properties of materials at high pressure in a gem anvil cell are reported. Thermal transport properties are determined by propagating a thermal wave in a material subjected to high pressures, and measuring the temperature as a function of time using an optical sensor embedded downstream in the material. Optical beams are used to deposit energy and to measure the sensor temperature and replace the resistive heat source and the thermocouples of previous methods. This overcomes the problems introduced with pressure-induced resistance changes and the spatial limitations inherent in previous high-pressure experimentation. Consistent with the heat conduction equation, the material's specific heat, thermal conductivity, and thermal diffusivity (κ) determine the sensor's temperature rise and its temporal profile. The all-optical technique described focuses on room-temperature thermal properties but can easily be applied to a wide temperature range (77-600 K). Measurements of thermal transport properties at pressure up to 2.0 GPa are reported, although extension to much higher pressures are feasible. The thermal properties of NaCl, a commonly used material for high-pressure experiments are measured and shown to be consistent with those obtained using the traditional methods.

  9. A novel vaporization-enucleation technique for benign prostate hyperplasia using 120-W HPS GreenLight™ laser: Seoul technique II in comparison with vaporization and previously reported modified vaporization-resection technique.

    PubMed

    Yoo, Sangjun; Park, Juhyun; Cho, Sung Yong; Cho, Min Chul; Jeong, Hyeon; Son, Hwancheol

    2017-12-01

    We developed a novel vaporization-enucleation technique (Seoul II), which consists of vaporization-enucleation of the prostate using 120-W HPS GreenLight laser, and enucleated prostate resection using bipolar devices for tissue removal. We compared the outcomes of the Seoul II with vaporization and a previously reported modified vaporization-resection technique (Seoul I). Among patients with benign prostate hyperplasia who underwent transurethral surgery using GreenLight laser at our institute, 347 patients with prostate volume ≥ 40 ml were included. The impact of surgical techniques on efficacy and postoperative functional outcomes was compared. No difference was found in baseline characteristics, although the prostate volume was marginally greater in Seoul II (p = 0.051). Prostate volume reduction per operation time (p < 0.001) and lasing time (p = 0.016) were greater in Seoul II. At postoperative 12 months, the International Prostate Symptom Score (I-PSS) was lower (p = 0.011), and the decrement in I-PSS was greater in Seoul II (p = 0.001) than other techniques. In multivariate analysis, postoperative 12-month I-PSS for Seoul II was significantly superior to vaporization (p < 0.001), although it was similar to Seoul I. The maintenance of immediate postoperative I-PSS decrement, until postoperative 12 months was superior in Seoul II compared with vaporization (p = 0.014) and Seoul I (p = 0.048). Seoul II showed improved efficacy and voiding functional maintenance over postoperative 12 months in patients with prostate volume ≥ 40 ml compared with vaporization and Seoul I. This technique could be easily accepted by clinicians who are familiar with GreenLight lasers and add flexibility to surgery without additional equipment.

  10. Optical digital chaos cryptography

    NASA Astrophysics Data System (ADS)

    Arenas-Pingarrón, Álvaro; González-Marcos, Ana P.; Rivas-Moscoso, José M.; Martín-Pereda, José A.

    2007-10-01

    In this work we present a new way to mask the data in a one-user communication system when direct sequence - code division multiple access (DS-CDMA) techniques are used. The code is generated by a digital chaotic generator, originally proposed by us and previously reported for a chaos cryptographic system. It is demonstrated that if the user's data signal is encoded with a bipolar phase-shift keying (BPSK) technique, usual in DS-CDMA, it can be easily recovered from a time-frequency domain representation. To avoid this situation, a new system is presented in which a previous dispersive stage is applied to the data signal. A time-frequency domain analysis is performed, and the devices required at the transmitter and receiver end, both user-independent, are presented for the optical domain.

  11. Femoral fracture repair using a locking plate technique in an adult captive polar bear (Ursus maritimus).

    PubMed

    Zimmerman, Dawn M; Dew, Terry; Douglass, Michael; Perez, Edward

    2010-02-01

    To report successful femoral fracture repair in a polar bear. Case report. Female polar bear (Ursus maritimus) 5 years and approximately 250 kg. A closed, complete, comminuted fracture of the distal midshaft femur was successfully reduced and stabilized using a compression plating technique with 2 specialized human femur plates offering axial, rotational, and bending support, and allowing the bone to share loads with the implant. Postoperative radiographs were obtained at 11.5 weeks, 11 months, and 24 months. Bone healing characterized by marked periosteal reaction was evident at 11 months with extensive remodeling evident at 24 months. No complications were noted. Distal mid shaft femoral fracture was reduced, stabilized, and healed in an adult polar bear with a locking plate technique using 2 plates. Previously, femoral fractures in polar bears were considered irreparable. Use of 2 plates applied with a locking plate technique can result in successful fracture repair despite large body weight and inability to restrict postoperative activity.

  12. Near-field Light Scattering Techniques for Measuring Nanoparticle-Surface Interaction Energies and Forces.

    PubMed

    Schein, Perry; Ashcroft, Colby K; O'Dell, Dakota; Adam, Ian S; DiPaolo, Brian; Sabharwal, Manit; Shi, Ce; Hart, Robert; Earhart, Christopher; Erickson, David

    2015-08-15

    Nanoparticles are quickly becoming commonplace in many commercial and industrial products, ranging from cosmetics to pharmaceuticals to medical diagnostics. Predicting the stability of the engineered nanoparticles within these products a priori remains an important and difficult challenge. Here we describe our techniques for measuring the mechanical interactions between nanoparticles and surfaces using near-field light scattering. Particle-surface interfacial forces are measured by optically "pushing" a particle against a reference surface and observing its motion using scattered near-field light. Unlike atomic force microscopy, this technique is not limited by thermal noise, but instead takes advantage of it. The integrated waveguide and microfluidic architecture allow for high-throughput measurements of about 1000 particles per hour. We characterize the reproducibility of and experimental uncertainty in the measurements made using the NanoTweezer surface instrument. We report surface interaction studies on gold nanoparticles with 50 nm diameters, smaller than previously reported in the literature using similar techniques.

  13. Facilitating children's views of therapy: an analysis of the use of play-based techniques to evaluate clinical practice.

    PubMed

    Jäger, Jessica

    2013-07-01

    This article reports on a follow-up study exploring the use of play-based evaluation methods to facilitate children's views of therapy. The development and piloting of these techniques, with 12 children in the author's own practice, was previously reported in this journal. It was argued that play-based evaluation methods reduce the power imbalance inherent in adult researcher/interviewer-child relationships and provide children with meaningful ways to share their views. In this article, follow-up research into play-based evaluations with 20 children and 7 different play therapists is drawn upon to explore in greater depth the strengths and weaknesses of these techniques. The study shows that play-based evaluation techniques are important and flexible methods for facilitating children's views of child therapy. It is argued that those play therapists who incorporate their therapeutic skills effectively, maintain flexibility and sensitively attune to the child during the evaluation session, enable the child to explore their views most fully.

  14. Martian Surface Compositions and Spectral Unit Mapping From the Thermal Emission Imaging System

    NASA Astrophysics Data System (ADS)

    Bandfield, J. L.; Christensen, P. R.; Rogers, D.

    2005-12-01

    The Thermal Emission Imaging System (THEMIS) on board the Mars Odyssey spacecraft observes Mars at nine spectral intervals between 6 and 15 microns and at 100 meter spatial sampling. This spectral and spatial resolution allows for mapping of local spectral units and coarse compositional determination of a variety of rock-forming materials such as carbonates, sulfates, and silicates. A number of data processing and atmospheric correction techniques have been developed to ease and speed the interpretation of multispectral THEMIS infrared images. These products and techniques are in the process of being made publicly available via the THEMIS website and were used to produce the results presented here. Spectral variability at kilometer scales in THEMIS data is more common in the southern highlands than in the northern lowlands. Many of the spectral units are associated with a mobile surface layer such as dune fields and mantled dust. However, a number of spectral units appear to be directly tied to the local geologic rock units. These spectral units are commonly associated with crater walls, floors, and ejecta blankets. Other surface compositions are correlated with layered volcanic materials and knobby remnant terrains. Most of the spectral variability observed to date appears to be tied to a variation in silicate mineralogy. Olivine rich units that have been previously reported in Nili Fossae, Ares Valles, and the Valles Marineris region appear to be sparse but common in a number of regions in the southern highlands. Variations in silica content consistent with previously reported global surface units also appear to be present in THEMIS images, allowing for an examination of their local geologic context. Previously reported quartz and feldspar rich exposures in northern Syrtis Major appear more extensive in the region than previously reported. A coherent global and local picture of the mineralogy of the Martian surface is emerging from THEMIS measurements along with other orbital thermal and near infrared spectroscopy measurements from the Mars Express and Mars Global Surveyor spacecraft.

  15. Laparoendoscopic Single-Site Cholecystectomy: First Experiences with a New Standardized Technique Replicating the Four-Port Technique.

    PubMed

    Morales-Conde, Salvador; Cañete-Gómez, Jesús; Gómez, Virginia; Socas Macías, María; Moreno, Antonio Barranco; Del Agua, Isaias Alarcón; Ruíz, Francisco Javier Padillo

    2016-10-01

    After reports on laparoendoscopic single-site (LESS) cholecystectomy, concerns have been raised over the level of difficulty and a potential increase in complications when moving away from conventional gold standard multiport laparoscopy due to incomplete exposure and larger umbilical incisions. With continued development of technique and technology, it has now become possible to fully replicate this gold standard procedure through an LESS approach. First experiences with the newly developed technique and instrument are reported. Fifteen patients presenting with cholelithiasis without signs of inflammation were operated using all surgical steps considered appropriate for the conventional four-port laparoscopic approach, but applied through a single access device. Operation-centered outcomes are presented. There were no peri- or postoperative complications. Mean operating time was 32.3 minutes. No conversion to regular laparoscopy was required. The critical view of safety was achieved in all cases. Mean skin incision length was 2.2 cm. The application of a standardized technique combined with the use of a four-port LESS device allows us to perform LESS cholecystectomy, giving us a correct exposure of the structures and without increasing the mean operating time combining previously reported advantages of LESS. A universal trait of any new technique should be safety and reproducibility. This will enhance its applicability by large number of surgeons and to large number of patients requiring cholecystectomy.

  16. Research on slow electron collision processes in gases. Final report, September 15, 1970--December 31, 1972

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baldwin, G C

    1974-04-30

    Research on low energy electron collisions in gases by the time-of- flight velocity selection technique included, as a preliminary to total cross section measurements, investigations of the statistical and systematic errors inherent in the technique. In particular, thermal transpiration and instrumental fluctuation errors in manometry were investigated, and the results embodied in computer programs for data reduction. The instrumental system was improved to permit extended periods of data accumulation without manual attention. Total cross section measurements in helium, made prior to, and in molecular nitrogen, made after the supporting work was completed, are reported. The total cross sec tion ofmore » helium is found to be higher than reported in previous beam determinations. That of nitrogen is found to be structureless at low energies. (auth)« less

  17. Reviewing the connection between speech and obstructive sleep apnea.

    PubMed

    Espinoza-Cuadros, Fernando; Fernández-Pozo, Rubén; Toledano, Doroteo T; Alcázar-Ramírez, José D; López-Gonzalo, Eduardo; Hernández-Gómez, Luis A

    2016-02-20

    Sleep apnea (OSA) is a common sleep disorder characterized by recurring breathing pauses during sleep caused by a blockage of the upper airway (UA). The altered UA structure or function in OSA speakers has led to hypothesize the automatic analysis of speech for OSA assessment. In this paper we critically review several approaches using speech analysis and machine learning techniques for OSA detection, and discuss the limitations that can arise when using machine learning techniques for diagnostic applications. A large speech database including 426 male Spanish speakers suspected to suffer OSA and derived to a sleep disorders unit was used to study the clinical validity of several proposals using machine learning techniques to predict the apnea-hypopnea index (AHI) or classify individuals according to their OSA severity. AHI describes the severity of patients' condition. We first evaluate AHI prediction using state-of-the-art speaker recognition technologies: speech spectral information is modelled using supervectors or i-vectors techniques, and AHI is predicted through support vector regression (SVR). Using the same database we then critically review several OSA classification approaches previously proposed. The influence and possible interference of other clinical variables or characteristics available for our OSA population: age, height, weight, body mass index, and cervical perimeter, are also studied. The poor results obtained when estimating AHI using supervectors or i-vectors followed by SVR contrast with the positive results reported by previous research. This fact prompted us to a careful review of these approaches, also testing some reported results over our database. Several methodological limitations and deficiencies were detected that may have led to overoptimistic results. The methodological deficiencies observed after critically reviewing previous research can be relevant examples of potential pitfalls when using machine learning techniques for diagnostic applications. We have found two common limitations that can explain the likelihood of false discovery in previous research: (1) the use of prediction models derived from sources, such as speech, which are also correlated with other patient characteristics (age, height, sex,…) that act as confounding factors; and (2) overfitting of feature selection and validation methods when working with a high number of variables compared to the number of cases. We hope this study could not only be a useful example of relevant issues when using machine learning for medical diagnosis, but it will also help in guiding further research on the connection between speech and OSA.

  18. Composeable Chat over Low-Bandwidth Intermittent Communication Links

    DTIC Science & Technology

    2007-04-01

    Compression (STC), introduced in this report, is a data compression algorithm intended to compress alphanumeric... Ziv - Lempel coding, the grandfather of most modern general-purpose file compression programs, watches for input symbol sequences that have previously... data . This section applies these techniques to create a new compression algorithm called Small Text Compression . Various sequence compression

  19. Controls on interannual variation in evapotranspiration and water use efficiency in a mature, furrow-irrigated peach orchard

    USDA-ARS?s Scientific Manuscript database

    Evapotranspiration (ET) and water use efficiency (WUE) in peach orchards has previously been observed in young (less than 5-8 years old), drip irrigated orchards using micrometeorological techniques such as Eddy Covariance or large-weighing lysimeters. However, no work has been reported on ET and W...

  20. Measuring Attending Behavior and Short-Term Memory with Knox's Cube Test.

    ERIC Educational Resources Information Center

    Stone, Mark H.; Wright, Benjamin D.

    1983-01-01

    A new revision was developed using Rasch psychometric techniques to build a Knox's Cube Test (KCT) variable and item bank using the tapping series from all previous editions. The report forms developed give a clear picture of the subject's performance set in a context that is both normative and criterion. (Author/BW)

  1. Class Size Revisited: Glass and Smith in Perspective.

    ERIC Educational Resources Information Center

    Hess, Fritz

    Gene V. Glass and Mary Lee Smith claim in their report, "Meta-Analysis of Research on the Relationship of Class-Size and Achievement" (ED 168 129), that their integration of data from 80 previous studies through complex regression analysis techniques revealed a "clear and strong relationship" between decreases in class size and increases in…

  2. In Vitro Susceptibilities of Mycoplasma hyopneumoniae Field Isolates

    PubMed Central

    Vicca, J.; Stakenborg, T.; Maes, D.; Butaye, P.; Peeters, J.; de Kruif, A.; Haesebrouck, F.

    2004-01-01

    The in vitro susceptibilities of 21 Mycoplasma hyopneumoniae field isolates were determined using a broth microdilution technique. One isolate showed acquired resistance to lincomycin, tilmicosin, and tylosin, while five isolates were resistant to flumequine and enrofloxacin. Acquired resistance against these antimicrobials in M. hyopneumoniae field isolates was not reported previously. PMID:15504886

  3. The Role of Education in Production Within the Household. Final Report.

    ERIC Educational Resources Information Center

    Michael, Robert T.

    This project is part of an ongoing study of the influence of schooling on observed household behavior. The study has previously determined that more educated individuals behave as if they are more proficient consumers, and that, in particular, more educated couples systematically select more efficient contraceptive techniques. The recent research…

  4. Preliminary engineering report for design of a subscale ejector/diffuser system for high expansion ratio space engine testing

    NASA Technical Reports Server (NTRS)

    Wojciechowski, C. J.; Kurzius, S. C.; Doktor, M. F.

    1984-01-01

    The design of a subscale jet engine driven ejector/diffuser system is examined. Analytical results and preliminary design drawings and plans are included. Previously developed performance prediction techniques are verified. A safety analysis is performed to determine the mechanism for detonation suppression.

  5. A Meta-Analysis of Previous Research on the Treatment of Hyperactivity. Final Report.

    ERIC Educational Resources Information Center

    White, Karl R.; And Others

    Using meta-analysis techniques, the study sought to identify, integrate, and synthesize the literature from 61 articles which review the efficacy of various treatments for hyperactive children. The major objectives were to determine if drugs can be used effectively with hyperactive children, what child and intervention characteristics covary with…

  6. Technology utilization in a non-urban region: Further impact and technique of the Technology Use Studies Center

    NASA Technical Reports Server (NTRS)

    1976-01-01

    Updated information is given pertaining to Technology Use Studies Center (TUSC) clients who are those that receive/use information as disseminated by the center. The client information is presented as a continuation of client data as set forth in the center's previous annual report.

  7. Metallurgical Research Relating to the Development of Metals and Alloys for Use in the High-Temperature Components of Jet-Engines, Gas Turbines and Other Aircraft Propulsion Systems

    NASA Technical Reports Server (NTRS)

    1948-01-01

    Considerable work has been done on report preparation. All items listed in the March program report will be reported during July. Fundamental studies are in progress to establish the fundamental processes by which treatments and composition control properties of commercial alloys at high temperatures. As yet work has been confined to Low-Carbon N155 alloy and progress has been reported twice previously. The work is divided into two sections: studies of solution treated and aged material and studies of rolled structures. Electron microscopic work has been started as an additional technique for the studies. Brief descriptions of experimental techniques used, results, and interpretation of the data obtained since the last report covering this field are summarized below. Since the work outlined is to a large extent still in progress, the discussion given is to be considered tentative and subject to further modification as additional data becomes available.

  8. NASAwide electronic publishing system: Electronic printing and duplicating, stage-2 evaluation report (GSFC)

    NASA Technical Reports Server (NTRS)

    Tuey, Richard C.; Lane, Robert; Hart, Susan V.

    1995-01-01

    The NASA Scientific and Technical Information Office was assigned the responsibility to continue with the expansion of the NASAwide networked electronic duplicating effort by including the Goddard Space Flight Center (GSFC) as an additional node to the existing configuration of networked electronic duplicating systems within NASA. The subject of this report is the evaluation of a networked electronic duplicating system which meets the duplicating requirements and expands electronic publishing capabilities without increasing current operating costs. This report continues the evaluation reported in 'NASA Electronic Publishing System - Electronic Printing and Duplicating Evaluation Report' (NASA TM-106242) and 'NASA Electronic Publishing System - Stage 1 Evaluation Report' (NASA TM-106510). This report differs from the previous reports through the inclusion of an external networked desktop editing, archival, and publishing functionality which did not exist with the previous networked electronic duplicating system. Additionally, a two-phase approach to the evaluation was undertaken; the first was a paper study justifying a 90-day, on-site evaluation, and the second phase was to validate, during the 90-day evaluation, the cost benefits and productivity increases that could be achieved in an operational mode. A benchmark of the functionality of the networked electronic publishing system and external networked desktop editing, archival, and publishing system was performed under a simulated daily production environment. This report can be used to guide others in determining the most cost effective duplicating/publishing alternative through the use of cost/benefit analysis and return on investment techniques. A treatise on the use of these techniques can be found by referring to 'NASA Electronic Publishing System -Cost/Benefit Methodology' (NASA TM-106662).

  9. Case reports to suggest an algorithm for management of total fertilisation failure prior to use of donor gametes.

    PubMed

    Nicopoullos, James D M; Whitney, E; Wells, V; Batha, S; Faris, R; Abdalla, H

    2015-11-01

    Total fertilisation failure (TFF), even with intracytoplasmic sperm injection (ICSI), occurs in approximately 3 % of cycles, can be recurrent and the exact cause is difficult to elucidate. Differentiation between oocyte and sperm-related cause of TFF is possible using mouse oocyte-activation techniques, but is not an option within most clinical settings. Therefore, the management of these couples is clinically driven, and the endpoint, if recurrent, is often the use of donor gametes. However, with the invariable lack of a definitive cause of TFF, any decision between the use of donor sperm or oocytes remains an emotive one. We present two case reports demonstrating the importance of appropriate investigation, activation techniques (mechanical and chemical) and clinical management options to develop a clinical algorithm prior to the use of donor gametes. This study is composed of two case reports of assisted reproduction investigation and treatment within an assisted conception unit for couples with recurrent total fertilisation failure. Using appropriate investigation (endocrine, urological and embryological) and treatments (ICSI, IMSI, oocyte-activation techniques), a fertilisation rate of 48 % was achieved in two cycles in couples following a total of nine previous cycles (and 200 previously collected eggs) with TFF. Oocyte activation requires the triggering of intracellular calcium oscillations by the release of a sperm-specific factor (phospholipase C zeta (PLCζ)) into the oocyte cytoplasm. Although, PLCζ deficiencies have been demonstrated as putative causes of failed activation, impaired oocyte responsiveness may also be a factor. The use of donor gametes is often recommended and is often the required endpoint of treatment. However, these reports outline a clinical algorithm that potentially offers success without donation, and also offers a systematic approach to help decide whether donor oocytes or sperm should be recommended.

  10. Implementation of spatial overlap modulation nonlinear optical microscopy using an electro-optic deflector

    PubMed Central

    Isobe, Keisuke; Kawano, Hiroyuki; Kumagai, Akiko; Miyawaki, Atsushi; Midorikawa, Katsumi

    2013-01-01

    A spatial overlap modulation (SPOM) technique is a nonlinear optical microscopy technique which enhances the three-dimensional spatial resolution and rejects the out-of-focus background limiting the imaging depth inside a highly scattering sample. Here, we report on the implementation of SPOM in which beam pointing modulation is achieved by an electro-optic deflector. The modulation and demodulation frequencies are enhanced to 200 kHz and 400 kHz, respectively, resulting in a 200-fold enhancement compared with the previously reported system. The resolution enhancement and suppression of the out-of-focus background are demonstrated by sum-frequency-generation imaging of pounded granulated sugar and deep imaging of fluorescent beads in a tissue-like phantom, respectively. PMID:24156055

  11. Multiclass Bayes error estimation by a feature space sampling technique

    NASA Technical Reports Server (NTRS)

    Mobasseri, B. G.; Mcgillem, C. D.

    1979-01-01

    A general Gaussian M-class N-feature classification problem is defined. An algorithm is developed that requires the class statistics as its only input and computes the minimum probability of error through use of a combined analytical and numerical integration over a sequence simplifying transformations of the feature space. The results are compared with those obtained by conventional techniques applied to a 2-class 4-feature discrimination problem with results previously reported and 4-class 4-feature multispectral scanner Landsat data classified by training and testing of the available data.

  12. General Aviation Interior Noise. Part 3; Noise Control Measure Evaluation

    NASA Technical Reports Server (NTRS)

    Unruh, James F.; Till, Paul D.; Palumbo, Daniel L. (Technical Monitor)

    2002-01-01

    The work reported herein is an extension to the work accomplished under NASA Grant NAG1-2091 on the development of noise/source/path identification techniques for single engine propeller driven General Aviation aircraft. The previous work developed a Conditioned Response Analysis (CRA) technique to identify potential noise sources that contributed to the dominating tonal responses within the aircraft cabin. The objective of the present effort was to improve and verify the findings of the CRA and develop and demonstrate noise control measures for single engine propeller driven General Aviation aircraft.

  13. Transbronchial cryobiopsy for diffuse parenchymal lung disease: a state-of-the-art review of procedural techniques, current evidence, and future challenges.

    PubMed

    Lentz, Robert J; Argento, A Christine; Colby, Thomas V; Rickman, Otis B; Maldonado, Fabien

    2017-07-01

    Transbronchial lung biopsy with a cryoprobe, or cryobiopsy, is a promising new bronchoscopic biopsy technique capable of obtaining larger and better-preserved samples than previously possible using traditional biopsy forceps. Over two dozen case series and several small randomized trials are now available describing experiences with this technique, largely for the diagnosis of diffuse parenchymal lung disease (DPLD), in which the reported diagnostic yield is typically 70% to 80%. Cryobiopsy technique varies widely between centers and this predominantly single center-based retrospective literature heterogeneously defines diagnostic yield and complications, limiting the degree to which this technique can be compared between centers or to surgical lung biopsy (SLB). This review explores the broad range of cryobiopsy techniques currently in use, their rationale, the current state of the literature, and suggestions for the direction of future study into this promising but unproven procedure.

  14. Soot Volume Fraction Imaging

    NASA Technical Reports Server (NTRS)

    Greenberg, Paul S.; Ku, Jerry C.

    1994-01-01

    A new technique is described for the full-field determination of soot volume fractions via laser extinction measurements. This technique differs from previously reported point-wise methods in that a two-dimensional array (i.e., image) of data is acquired simultaneously. In this fashion, the net data rate is increased, allowing the study of time-dependent phenomena and the investigation of spatial and temporal correlations. A telecentric imaging configuration is employed to provide depth-invariant magnification and to permit the specification of the collection angle for scattered light. To improve the threshold measurement sensitivity, a method is employed to suppress undesirable coherent imaging effects. A discussion of the tomographic inversion process is provided, including the results obtained from numerical simulation. Results obtained with this method from an ethylene diffusion flame are shown to be in close agreement with those previously obtained by sequential point-wise interrogation.

  15. Solving the shrinkage-induced PDMS alignment registration issue in multilayer soft lithography

    NASA Astrophysics Data System (ADS)

    Moraes, Christopher; Sun, Yu; Simmons, Craig A.

    2009-06-01

    Shrinkage of polydimethylsiloxane (PDMS) complicates alignment registration between layers during multilayer soft lithography fabrication. This often hinders the development of large-scale microfabricated arrayed devices. Here we report a rapid method to construct large-area, multilayered devices with stringent alignment requirements. This technique, which exploits a previously unrecognized aspect of sandwich mold fabrication, improves device yield, enables highly accurate alignment over large areas of multilayered devices and does not require strict regulation of fabrication conditions or extensive calibration processes. To demonstrate this technique, a microfabricated Braille display was developed and characterized. High device yield and accurate alignment within 15 µm were achieved over three layers for an array of 108 Braille units spread over a 6.5 cm2 area, demonstrating the fabrication of well-aligned devices with greater ease and efficiency than previously possible.

  16. Experimental study of catalytic hydrogenation by using an in-situ hydrogen measuring technique. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chiang, S.H.; Klinzing, G.E.; Cheng, Y.S.

    1984-12-01

    An in-situ technique for measuring hydrogen concentration (partial pressure) had been previously used to measure static properties (hydrogen solubilities, vapor pressures of hydrocarbons, etc.). Because of its good precision (2% relative error) and relatively short respond time (9.7 to 2.0 seconds at 589 to 728K), the technique was successfully applied to a dynamic study of hydrogenation reactions in this work. Furthermore, the technique is to be tested for industrial uses. Hydrogen/1-methylnaphthalene system was experimentally investigated in a one-liter autoclave equipped with a magnetically driven stirrer and temperature controlling devices. Catalytic hydrogenation of 1-methylnaphthalene was studied in the presence of sulfidedmore » Co-Mo-Al2O3 catalyst. In addition, the vapor/liquid equilibrium relationship was determined by using this technique. Hydrogenation reaction runs were performed at temperatures of 644.1, 658.0 and 672.0K and pressures up to 9.0 MPa. The ring hydrogenation, resulting in 1- and 5-methyltetralin, was found to be the dominant reaction. This is in agreement with cited literature. Effects of hydrogen partial pressure, operating temperature, as well as presulfided catalyst are also investigated and discussed in this work. The vapor pressure of 1-methylnaphthalene was measured over a temperature range of 555.2 to 672.0K. The results are in good agreement with literature data. Measurements for hydrogen solubility in 1-methylnaphthalene were conducted over temperature and pressure range of 598 to 670K and 5.2 to 8.8 MPa, respectively. Similar to previously reported results, the hydrogen solubility increases with increasing temperature when total pressure is held constant. A linear relation is found between the hydrogen solubility and hydrogen partial pressure. 21 refs., 13 figs., 10 tabs.« less

  17. Simultaneous detection of six urinary pteridines and creatinine by high-performance liquid chromatography-tandem mass spectrometry for clinical breast cancer detection.

    PubMed

    Burton, Casey; Shi, Honglan; Ma, Yinfa

    2013-11-19

    Recent preliminary studies have implicated urinary pteridines as candidate biomarkers in a growing number of malignancies including breast cancer. While the developments of capillary electrophoresis-laser induced fluorescence (CE-LIF), high performance liquid chromatography (HPLC), and liquid chromatography-mass spectroscopy (LC-MS) pteridine urinalyses among others have helped to enable these findings, limitations including poor pteridine specificity, asynchronous or nonexistent renal dilution normalization, and a lack of information regarding adduct formation in mass spectrometry techniques utilizing electrospray ionization (ESI) have prevented application of these techniques to a larger clinical setting. In this study, a simple, rapid, specific, and sensitive high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method has been developed and optimized for simultaneous detection of six pteridines previously implicated in breast cancer and creatinine as a renal dilution factor in urine. In addition, this study reports cationic adduct formation of urinary pteridines under ESI-positive ionization for the first time. This newly developed technique separates and detects the following six urinary pteridines: 6-biopterin, 6-hydroxymethylpterin, d-neopterin, pterin, isoxanthopterin, and xanthopterin, as well as creatinine. The method detection limit for the pteridines is between 0.025 and 0.5 μg/L, and for creatinine, it is 0.15 μg/L. The method was also validated by spiked recoveries (81-105%), reproducibility (RSD: 1-6%), and application to 25 real urine samples from breast cancer positive and negative samples through a double-blind study. The proposed technique was finally compared directly with a previously reported CE-LIF technique, concluding that additional or alternative renal dilution factors are needed for proper investigation of urinary pteridines as breast cancer biomarkers.

  18. Flight test experience with high-alpha control system techniques on the F-14 airplane

    NASA Technical Reports Server (NTRS)

    Gera, J.; Wilson, R. J.; Enevoldson, E. K.; Nguyen, L. T.

    1981-01-01

    Improved handling qualities of fighter aircraft at high angles of attack can be provided by various stability and control augmentation techniques. NASA and the U.S. Navy are conducting a joint flight demonstration of these techniques on an F-14 airplane. This paper reports on the flight test experience with a newly designed lateral-directional control system which suppresses such high angle of attack handling qualities problems as roll reversal, wing rock, and directional divergence while simultaneously improving departure/spin resistance. The technique of integrating a piloted simulation into the flight program was used extensively in this program. This technique had not been applied previously to high angle of attack testing and required the development of a valid model to simulate the test airplane at extremely high angles of attack.

  19. Reflection coefficients of permeant molecules in human red cell suspensions.

    PubMed

    Owen, J D; Eyring, E M

    1975-08-01

    The Staverman reflection coefficient, sigma for several permeant molecules was determined in human red cell suspensions with a Durrum stopped-flow spectrophotometer. This procedure was first used with dog, cat, and beef red cells and with human red cells. The stopped-flow technique used was similar to the rapid-flow method used by those who originally reported sigma measurements in human red cells for molecules which rapidly penetrate the red cell membrane. The sigma values we obtained agreed with those previously reported for most of the slow penetrants, except malonamide, but disagreed with all the sigma values previously reported for the rapid penetrants. We were unable to calculate an "equivalent pore radius" with our sigma data. The advantages of our equipment and our experimental procedure are discussed. Our sigma data suggest that sigma is indirectly proportional to the log of the nonelectrolyte permeability coefficient, omega. Since a similar trend has been previously shown for log omega and molar volume of the permeant molecules, a correlatioo was shown between sigma and molar volume suggesting the membrane acts as a sieve.

  20. FOLLOW-UP ALPHA-TRACK MONITORING IN 40 EASTERN PENNSYLVANIA HOUSES WITH INDOOR RADON REDUCTION SYSTEMS (WINTER 1988-89)

    EPA Science Inventory

    The report gives results of 4-month-long alpha-track detector (ATD) measurements of indoor radon concentrations, completed during the winter of 1988-89 in 38 of 40 houses where radon reduction techniques had been installed 2-4 years previously during an earlier EPA project. The t...

  1. FOLLOW-UP ANNUAL ALPHA-TRACK MONITORING IN 40 EASTERN PENNSYLVANIA HOUSES WITH INDOOR RADON REDUCTION SYSTEMS (DECEMBER 1988 - DECEMBER 1989)

    EPA Science Inventory

    The report gives results of 12-month-long alpha-track detector (ATD) measurements of indoor radon concentrations, between December 1988 and December 1989 in the living areas of 38 of 40 houses where radon reduction techniques had been installed 2-4 years earlier in a previous EPA...

  2. Technical Innovation Case Report: Ultrasound-Guided Prolotherapy Injection for Insertional Achilles Calcific Tendinosis

    PubMed Central

    DeLuca, Jesse P.; Lammlein, Kyle P.

    2016-01-01

    We describe the use of ultrasound guidance for hyperosmolar dextrose (prolotherapy) injection of the distal calcaneal tendon specifically just anterior to identified enthesophytes in patients with insertional Achilles calcific tendinosis refractory to conservative treatment. This specific technique has not to our knowledge been described or used in literature previously. PMID:27974984

  3. Eradicating European pine shoot moth in commercial nurseries with methyl bromide.

    Treesearch

    V.M. Carolin; W.K. Coulter

    1963-01-01

    This is the third in a series of reports on experimental fumigation of the European pine shoot moth in residential areas and nurseries. Methods and techniques derived in previous studies on single ornamentals were adapted to fumigation of a commercial nursery. An elongate cubical chamber was built for treatment of trees in rows. Fumigation of an...

  4. Critically endangered blonde capuchins fish for termites and use new techniques to accomplish the task

    PubMed Central

    Souto, Antonio; Bione, Camila B. C.; Bastos, Monique; Bezerra, Bruna M.; Fragaszy, Dorothy; Schiel, Nicola

    2011-01-01

    We report the spontaneous modification and use of sticks to fish for termites, above the ground, in wild blonde capuchins (Cebus flavius). These critically endangered Neotropical primates inhabit remnants of the Atlantic Forest. They used two previously undescribed techniques to enhance their termite capture success: nest tapping and stick rotation. The current ecologically based explanation for tool use in wild capuchins (i.e. terrestrial habits and bipedalism) must be viewed cautiously. Instead, remarkable manual skills linked to a varied diet seem important in promoting tool use in different contexts. The repertoire of tool-using techniques employed by wild capuchins has been expanded, highlighting the behavioural versatility in this genus. PMID:21389018

  5. Summary: Update to ASTM Guide E 1523 to Charge Control and Charge Referencing Techniques in X-ray Photoelectron Spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baer, Donald R.

    2005-04-22

    An updated version of the ASTM guide E1523 to the methods to charge control and charge referencing techniques in x-ray photoelectron spectroscopy has been released by ASTM. The guide is meant to acquaint x-ray photoelectron spectroscopy (XPS) users with the various charge control and charge referencing techniques that are and have been used in the acquisition and interpretation of XPS data from surfaces of insulating specimens. The current guide has been expanded to include new references as well as recommendations for reporting information on charge control and charge referencing. The previous version of the document had been published in 1997.

  6. Verification of otolith identity used by fisheries scientists for aging channel catfish

    USGS Publications Warehouse

    Long, James M.; Stewart, David R.

    2010-01-01

    Previously published studies of the age estimation of channel catfish Ictalurus punctatus based on otoliths have reported using the sagittae, whereas it is likely they were actually using the lapilli. This confusion may have resulted because in catfishes (ostariophyseans) the lapilli are the largest of the three otoliths, whereas in nonostariophysean fish the sagittae are the largest. Based on (1) scanning electron microscope microphotographs of channel catfish otoliths, (2) X-ray computed tomography scans of a channel catfish head, (3) descriptions of techniques used to removed otoliths from channel catfish reported in the literature, and (4) a sample of channel catfish otoliths received from fisheries biologists from around the country, it is clear that lapilli are most often used for channel catfish aging studies, not sagittae, as has been previously reported. Fisheries scientists who obtain otoliths from channel catfish can use the information in this paper to correctly identify otolith age.

  7. Quantification of false positive reduction in nucleic acid purification on hemorrhagic fever DNA.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    James, Conrad D.; Pohl, Kenneth Roy; Derzon, Mark Steven

    2006-11-01

    Columbia University has developed a sensitive highly multiplexed system for genetic identification of nucleic acid targets. The primary obstacle to implementing this technology is the high rate of false positives due to high levels of unbound reporters that remain within the system after hybridization. The ability to distinguish between free reporters and reporters bound to targets limits the use of this technology. We previously demonstrated a new electrokinetic method for binary separation of kb pair long DNA molecules and oligonucleotides. The purpose of this project 99864 is to take these previous demonstrations and further develop the technique and hardware formore » field use. Specifically, our objective was to implement separation in a heterogeneous sample (containing target DNA and background oligo), to perform the separation in a flow-based device, and to develop all of the components necessary for field testing a breadboard prototype system.« less

  8. Application of nonlinear ultrasonics to inspection of stainless steel for dry storage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ulrich, Timothy James II; Anderson, Brain E.; Remillieux, Marcel C.

    This report summarized technical work conducted by LANL staff an international collaborators in support of the UFD Storage Experimentation effort. The focus of the current technical work is on the detection and imaging of a failure mechanism known as stress corrosion cracking (SCC) in stainless steel using the nonlinear ultrasonic technique known as TREND. One of the difficulties faced in previous work is in finding samples that contain realistically sized SCC. This year such samples were obtained from EPRI. Reported here are measurements made on these samples. One of the key findings is the ability to detect subsurface changes tomore » the direction in which a crack is penetrating into the sample. This result follows from last year's report that demonstrated the ability of TREND techniques to image features below the sample surface. A new collaboration was established with AGH University of Science and Technology, Krakow, Poland.« less

  9. F-111 Adhesive Bonded Repairs Assessment Program - Progress Report 2: Analysis of FM300-2K Repairs

    DTIC Science & Technology

    2015-01-01

    primarily the effect of panel skin thickness The previous report found that while repair location on the aircraft structure may have had some effect...typically are manufactured by adhesively bonding an upper and lower aluminium skin to aluminium honeycomb-core. The structure provides added stiffness to...component, one of the typical repair techniques requires removal of the damaged skin and honeycomb core. New core is adhesively bonded back in place and an

  10. Interleaved diffusion-weighted EPI improved by adaptive partial-Fourier and multi-band multiplexed sensitivity-encoding reconstruction

    PubMed Central

    Chang, Hing-Chiu; Guhaniyogi, Shayan; Chen, Nan-kuei

    2014-01-01

    Purpose We report a series of techniques to reliably eliminate artifacts in interleaved echo-planar imaging (EPI) based diffusion weighted imaging (DWI). Methods First, we integrate the previously reported multiplexed sensitivity encoding (MUSE) algorithm with a new adaptive Homodyne partial-Fourier reconstruction algorithm, so that images reconstructed from interleaved partial-Fourier DWI data are free from artifacts even in the presence of either a) motion-induced k-space energy peak displacement, or b) susceptibility field gradient induced fast phase changes. Second, we generalize the previously reported single-band MUSE framework to multi-band MUSE, so that both through-plane and in-plane aliasing artifacts in multi-band multi-shot interleaved DWI data can be effectively eliminated. Results The new adaptive Homodyne-MUSE reconstruction algorithm reliably produces high-quality and high-resolution DWI, eliminating residual artifacts in images reconstructed with previously reported methods. Furthermore, the generalized MUSE algorithm is compatible with multi-band and high-throughput DWI. Conclusion The integration of the multi-band and adaptive Homodyne-MUSE algorithms significantly improves the spatial-resolution, image quality, and scan throughput of interleaved DWI. We expect that the reported reconstruction framework will play an important role in enabling high-resolution DWI for both neuroscience research and clinical uses. PMID:24925000

  11. Repair of Double Head Pectoralis Major Tendon Avulsion into its Native Footprint Using Bi-cortical EndoButtons and Tendon Sliding Technique.

    PubMed

    Prabhu, Jagadish; Faqi, Mohammed Khalid; Alkhalifa, Fahad; Tayara, Bader Kamal; Awad, Rashad Khamis

    2017-01-01

    Injuries to the pectoralis major muscle are relatively infrequent. The mechanism of injury is usually an eccentric shortening of the pectoralis major under heavy load, such as when performing a bench press exercise. We report a case that presented to us with a history of sudden pain in the left pectoral region while doing heavy bench press exercise. The patient sustained a type III D pectoralis muscle -tendon avulsion. Surgical repair was done through a bi-cortical tendon sliding technique using two cortical buttons. In this article we describe our modifications to the previously described surgical technique for the pectoralis major tendon repair using the EndoButton and tension - slide technique, aiming to overcome the possible complications.

  12. The trans-frontal-sinus subcranial approach for removal of large olfactory groove meningiomas: surgical technique and comparison to other approaches.

    PubMed

    Boari, Nicola; Gagliardi, Filippo; Roberti, Fabio; Barzaghi, Lina Raffaella; Caputy, Anthony J; Mortini, Pietro

    2013-05-01

    Several surgical approaches have been previously reported for the treatment of olfactory groove meningiomas (OGM).The trans-frontal-sinus subcranial approach (TFSSA) for the removal of large OGMs is described, comparing it with other reported approaches in terms of advantages and drawbacks. The TFSSA was performed on cadaveric specimens to illustrate the surgical technique. The surgical steps of the TFSSA and the related anatomical pictures are reported. The approach was adopted in a clinical setting; a case illustration is reported to demonstrate the feasibility of the described approach and to provide intraoperative pictures. The TFSSA represents a possible route to treat large OGMs. The subcranial approach provides early devascularization of the tumor, direct tumor access from the base without traction on the frontal lobes, good overview of dissection of the optic nerves and anterior cerebral arteries, and dural reconstruction with pedicled pericranial flap. Georg Thieme Verlag KG Stuttgart · New York.

  13. A Novel Vesicoscopic Bladder Wall Suture Fixation Technique to Aid Endoscopic Vesicostomy Button Insertion

    PubMed Central

    Adam, Ahmed; Sookram, Jayveer

    2018-01-01

    Background To describe a novel bladder fixation technique for use during endoscopic vesicostomy button insertion. Methods After standard cystoscopic visualization of the bladder, a standard 18 G intravenous cannula was inserted into the bladder. A non-absorbable suture thread was placed through this intravenous cannula under cystoscopic vision. The proximal end of the suture was then removed using standard ureteroscopic grasping forceps (3 Fr) through another needle (15 G) inserted next to the initial puncture site (following a path at 30 degrees from the initial puncture tract) into the bladder. The suture ends were brought out of the bladder and tied at the skin level, 2 cm from the intended vesicostomy site. Sutures were removed on the second postoperative day. Results This fixation technique allows for adequate fixation of the bladder dome to the anterior abdominal wall. These sutures also have less potential for cutaneous scarring and pain. No complications were reported. Conclusion This simple fixation technique is easily performed using materials found in every urology suite. It also avoids the skills required with other previously reported fixation suture techniques, and can also be utilized for bladder fixation in cases of vesicoscopic laparoscopic or robotic assisted laparoscopic procedures. PMID:29692696

  14. Repair of distal biceps tendon rupture with the Biotenodesis screw.

    PubMed

    Khan, W; Agarwal, M; Funk, L

    2004-04-01

    Distal biceps tendon ruptures are uncommon injuries with only around 300 cases reported in the literature. Current management tends to favour anatomical reinsertion of the tendon into the radial tuberosity, especially in young and active individuals. These injuries are commonly repaired using either a single anterior incision with suture anchors or the Boyd-Anderson dual incision technique. We report the use of a bioabsorbable interference screw for the repair of distal biceps tendon rupture using a minimal incision technique. In this technique the avulsed tendon and a bioabsorbable screw are secured in a drill hole on the radial tuberosity using whip stitch and fibre wire sutures according to Biotenodesis system guidelines. The technique described requires minimal volar dissection that is associated with a reduced number of synostosis and posterior interosseous nerve injuries. The bioabsorbable interference screw has all the advantages of being biodegradable and has been shown to have greater pullout strength than suture anchors. It is also a reasonable alternative to titanium screws in terms of primary fixation strength. The strong fixation provided allows early active motion and return to previous activities as seen in our case.

  15. Analysis of Spectral-type A/B Stars in Five Open Clusters

    NASA Astrophysics Data System (ADS)

    Wilhelm, Ronald J.; Rafuil Islam, M.

    2014-01-01

    We have obtained low resolution (R = 1000) spectroscopy of N=68, spectral-type A/B stars in five nearby open star clusters using the McDonald Observatory, 2.1m telescope. The sample of blue stars in various clusters were selected to test our new technique for determining interstellar reddening and distances in areas where interstellar reddening is high. We use a Bayesian approach to find the posterior distribution for Teff, Logg and [Fe/H] from a combination of reddened, photometric colors and spectroscopic line strengths. We will present calibration results for this technique using open cluster star data with known reddening and distances. Preliminary results suggest our technique can produce both reddening and distance determinations to within 10% of cluster values. Our technique opens the possibility of determining distances for blue stars at low Galactic latitudes where extinction can be large and differential. We will also compare our stellar parameter determinations to previously reported MK spectral classifications and discuss the probability that some of our stars are not members of their reported clusters.

  16. Analytical procedures for estimating structural response to acoustic fields generated by advanced launch systems, phase 2

    NASA Technical Reports Server (NTRS)

    Elishakoff, Isaac; Lin, Y. K.; Zhu, Li-Ping; Fang, Jian-Jie; Cai, G. Q.

    1994-01-01

    This report supplements a previous report of the same title submitted in June, 1992. It summarizes additional analytical techniques which have been developed for predicting the response of linear and nonlinear structures to noise excitations generated by large propulsion power plants. The report is divided into nine chapters. The first two deal with incomplete knowledge of boundary conditions of engineering structures. The incomplete knowledge is characterized by a convex set, and its diagnosis is formulated as a multi-hypothesis discrete decision-making algorithm with attendant criteria of adaptive termination.

  17. Development of a noninvasive technique for the measurement of intracranial pressure

    NASA Technical Reports Server (NTRS)

    Ueno, T.; Shuer, L. M.; Yost, W. T.; Hargens, A. R.

    1998-01-01

    Intracranial pressure (ICP) dynamics are important for understanding adjustments to altered gravity. Previous flight observations document significant facial edema during exposure to microgravity, which suggests that ICP is elevated during microgravity. However, there are no experimental results obtained during space flight, primarily due to the invasiveness of currently available techniques. We have developed and refined a noninvasive technique to measure intracranial pressure noninvasively. The technique is based upon detecting skull movements of a few micrometers in association with altered intracranial pressure. We reported that the PPLL technique has enough sensitivity to detect changes in cranial distance associated with the pulsation of ICP in cadavera. In normal operations, however, we place a transducer on the scalp. Thus, we cannot rule out the possibility that the PPLL technique picks up cutaneous pulsation. The purpose of the present study was therefore to show that the PPLL technique has enough sensitivity to detect changes in cranial distance associated with cardiac cycles in vivo.

  18. Determination of zircon/melt trace element partition coefficients from SIMS analysis of melt inclusions in zircon

    NASA Astrophysics Data System (ADS)

    Thomas, J. B.; Bodnar, R. J.; Shimizu, N.; Sinha, A. K.

    2002-09-01

    Partition coefficients ( zircon/meltD M) for rare earth elements (REE) (La, Ce, Nd, Sm, Dy, Er and Yb) and other trace elements (Ba, Rb, B, Sr, Ti, Y and Nb) between zircon and melt have been calculated from secondary ion mass spectrometric (SIMS) analyses of zircon/melt inclusion pairs. The melt inclusion-mineral (MIM) technique shows that D REE increase in compatibility with increasing atomic number, similar to results of previous studies. However, D REE determined using the MIM technique are, in general, lower than previously reported values. Calculated D REE indicate that light REE with atomic numbers less than Sm are incompatible in zircon and become more incompatible with decreasing atomic number. This behavior is in contrast to most previously published results which indicate D > 1 and define a flat partitioning pattern for elements from La through Sm. The partition coefficients for the heavy REE determined using the MIM technique are lower than previously published results by factors of ≈15 to 20 but follow a similar trend. These differences are thought to reflect the effects of mineral and/or glass contaminants in samples from earlier studies which employed bulk analysis techniques. D REE determined using the MIM technique agree well with values predicted using the equations of Brice (1975), which are based on the size and elasticity of crystallographic sites. The presence of Ce 4+ in the melt results in elevated D Ce compared to neighboring REE due to the similar valence and size of Ce 4+ and Zr 4+. Predicted zircon/meltD values for Ce 4+ and Ce 3+ indicate that the Ce 4+/Ce 3+ ratios of the melt ranged from about 10 -3 to 10 -2. Partition coefficients for other trace elements determined in this study increase in compatibility in the order Ba < Rb < B < Sr < Ti < Y < Nb, with Ba, Rb, B and Sr showing incompatible behavior (D M < 1.0), and Ti, Y and Nb showing compatible behavior (D M > 1.0). The effect of partition coefficients on melt evolution during petrogenetic modeling was examined using partition coefficients determined in this study and compared to trends obtained using published partition coefficients. The lower D REE determined in this study result in smaller REE bulk distribution coefficients, for a given mineral assemblage, compared to those calculated using previously reported values. As an example, fractional crystallization of an assemblage composed of 35% hornblende, 64.5% plagioclase and 0.5% zircon produces a melt that becomes increasingly more enriched in Yb using the D Yb from this study. Using D Yb from Fujimaki (1986) results in a melt that becomes progressively depleted in Yb during crystallization.

  19. Diagnosis of human fascioliasis by stool and blood techniques: update for the present global scenario.

    PubMed

    Mas-Coma, S; Bargues, M D; Valero, M A

    2014-12-01

    Before the 1990s, human fascioliasis diagnosis focused on individual patients in hospitals or health centres. Case reports were mainly from developed countries and usually concerned isolated human infection in animal endemic areas. From the mid-1990s onwards, due to the progressive description of human endemic areas and human infection reports in developing countries, but also new knowledge on clinical manifestations and pathology, new situations, hitherto neglected, entered in the global scenario. Human fascioliasis has proved to be pronouncedly more heterogeneous than previously thought, including different transmission patterns and epidemiological situations. Stool and blood techniques, the main tools for diagnosis in humans, have been improved for both patient and survey diagnosis. Present availabilities for human diagnosis are reviewed focusing on advantages and weaknesses, sample management, egg differentiation, qualitative and quantitative diagnosis, antibody and antigen detection, post-treatment monitoring and post-control surveillance. Main conclusions refer to the pronounced difficulties of diagnosing fascioliasis in humans given the different infection phases and parasite migration capacities, clinical heterogeneity, immunological complexity, different epidemiological situations and transmission patterns, the lack of a diagnostic technique covering all needs and situations, and the advisability for a combined use of different techniques, at least including a stool technique and a blood technique.

  20. Pulsed NMRON relaxation measurements and thermometric NMR in the quasi-2 dimensional femomagnet: Mn(COOCH 3) 2·4H 2O

    NASA Astrophysics Data System (ADS)

    Le Gros, M.; Kotlicld, A.; Turrell, B. G.

    1990-08-01

    The measurement of the field dependence of the nuclear spin-lattice relaxation time of 54Mn in the two manganese sites in the quasi-2 dimensional ferromagnet Mn(COOCH 3) 2·4H 20 obtained by the pulsed NMRON technique is reported. This technique allows the observation in low fields of the higher frequency resonance which previously could not be measured by CW methods. The anomaly in the 54Mn relaxation time observed in the 55Mn level crossing regime is discussed, and the thermometric observation of the field dependence and lice width of the resonance lines from the abundant 55Mn spin systems is reported and related to the 54Mn spin-lattice relaxation behavior.

  1. Fabrication of scalable tissue engineering scaffolds with dual-pore microarchitecture by combining 3D printing and particle leaching.

    PubMed

    Mohanty, Soumyaranjan; Sanger, Kuldeep; Heiskanen, Arto; Trifol, Jon; Szabo, Peter; Dufva, Marin; Emnéus, Jenny; Wolff, Anders

    2016-04-01

    Limitations in controlling scaffold architecture using traditional fabrication techniques are a problem when constructing engineered tissues/organs. Recently, integration of two pore architectures to generate dual-pore scaffolds with tailored physical properties has attracted wide attention in tissue engineering community. Such scaffolds features primary structured pores which can efficiently enhance nutrient/oxygen supply to the surrounding, in combination with secondary random pores, which give high surface area for cell adhesion and proliferation. Here, we present a new technique to fabricate dual-pore scaffolds for various tissue engineering applications where 3D printing of poly(vinyl alcohol) (PVA) mould is combined with salt leaching process. In this technique the sacrificial PVA mould, determining the structured pore architecture, was filled with salt crystals to define the random pore regions of the scaffold. After crosslinking the casted polymer the combined PVA-salt mould was dissolved in water. The technique has advantages over previously reported ones, such as automated assembly of the sacrificial mould, and precise control over pore architecture/dimensions by 3D printing parameters. In this study, polydimethylsiloxane and biodegradable poly(ϵ-caprolactone) were used for fabrication. However, we show that this technique is also suitable for other biocompatible/biodegradable polymers. Various physical and mechanical properties of the dual-pore scaffolds were compared with control scaffolds with either only structured or only random pores, fabricated using previously reported methods. The fabricated dual-pore scaffolds supported high cell density, due to the random pores, in combination with uniform cell distribution throughout the scaffold, and higher cell proliferation and viability due to efficient nutrient/oxygen transport through the structured pores. In conclusion, the described fabrication technique is rapid, inexpensive, scalable, and compatible with different polymers, making it suitable for engineering various large scale organs/tissues. Copyright © 2015. Published by Elsevier B.V.

  2. Restoration of Complicated Epicanthus: Modified Reverse Skin Redraping With Mini-epicanthoplasty for Rescue in Unsatisfied Epicanthoplasty Patients.

    PubMed

    Chung, Yoon Jae; Han, Kyung Eun; Park, Bo Young

    2017-06-01

    We had reported the surgical outcome of reverse skin redraping technique for restoration of previously performed epicanthoplasty. In this study, we introduce a modified reverse skin redraping technique that added mini-epicanthoplasty in patients with unsatisfactory results after epicanthoplasty. Three hundred twenty-four patients (288 female and 36 male patients) who had unsatisfied results with previous epicanthoplasty and that were treated with our modified restoration surgery were included in this study. The mean preoperative interepicanthal distance was 33.6 mm, and the mean postoperative interepicanthal distance was 36.9 mm; the mean difference in the interepicanthal distance before and after restoration surgery was 3.3 mm. Satisfactory aesthetic results were obtained with improvements in areas of asymmetry, overexposure of the caruncle, and the appearance of the previous scar. Only minor complications developed in 15 patients (4.6%) that were resolved with minor revisions. No severe complications requiring reoperations were noted. Our modified method involving reverse skin redraping and mini-epicanthoplasty is simple and reproducible and is useful for resolution of unsatisfactory results to obtain a naturally shaped epicanthus.

  3. Extremes of urine osmolality - Lack of effect on red blood cell survival

    NASA Technical Reports Server (NTRS)

    Leon, H. A.; Fleming, J. E.

    1980-01-01

    Rats were allowed a third of normal water intake for 20 days, and food consumption decreased. The reticulocyte count indicated a suppression of erythropoiesis. Urine osmolality increased from 2,000 mosmol/kg to 3,390 mosmol/kg. Random hemolysis and senescence of a cohort of red blood cell (RBC) previously labeled with (2-(C-14)) glycine was monitored via the production of (C-14)O. Neither hemolysis nor senescence was affected. Following water restriction, the polydipsic rats generated a hypotonic urine. Urine osmolality decreased to 1,300 mosmol/kg for at least 6 days; a reticulocytosis occurred, but RBC survival was unaffected. These results contradict those previously reported, which suggest that RBC survival is influenced by the osmotic stress imposed on the RBC by extremes of urine tonicity. This discrepancy, it is concluded, is due to differences in the methods employed for measuring RBC survival. The random-labeling technique employed previously assumes a steady state between RBC production and destruction. The cohort-labeling technique used here measures hemolysis and senescence independent of changes in RBC production, which is known to be depressed by fasting.

  4. Exchange-mediated spin-lattice relaxation of Fe3+ ions in borate glasses.

    PubMed

    Misra, Sushil K; Pilbrow, John R

    2007-03-01

    Spin-lattice relaxation times (T1) of two borate glasses doped with different concentrations of Fe2O3 were measured using the Electron Spin-Echo (ESE) technique at X-band (9.630 GHz) in the temperature range 2-6K. In comparison with a previous investigation of Fe3+-doped silicate glasses, the relaxation rates were comparable and differed by no more than a factor of two. The data presented here extend those previously reported for borate glasses in the 10-250K range but measured using the amplitude-modulation technique. The T1 values were found to depend on temperature (T) as T(n) with n approximately 1 for the 1% and 0.1% Fe2O3-doped glass samples. These results are consistent with spin-lattice relaxation as effected by exchange interaction of a Fe3+ spin exchange-coupled to another Fe3+ spin in an amorphous material.

  5. Comparison of Maximal Wall Thickness in Hypertrophic Cardiomyopathy Differs Between Magnetic Resonance Imaging and Transthoracic Echocardiography.

    PubMed

    Bois, John P; Geske, Jeffrey B; Foley, Thomas A; Ommen, Steve R; Pellikka, Patricia A

    2017-02-15

    Left ventricular (LV) wall thickness is a prognostic marker in hypertrophic cardiomyopathy (HC). LV wall thickness ≥30 mm (massive hypertrophy) is independently associated with sudden cardiac death. Presence of massive hypertrophy is used to guide decision making for cardiac defibrillator implantation. We sought to determine whether measurements of maximal LV wall thickness differ between cardiac magnetic resonance imaging (MRI) and transthoracic echocardiography (TTE). Consecutive patients were studied who had HC without previous septal ablation or myectomy and underwent both cardiac MRI and TTE at a single tertiary referral center. Reported maximal LV wall thickness was compared between the imaging techniques. Patients with ≥1 technique reporting massive hypertrophy received subset analysis. In total, 618 patients were evaluated from January 1, 2003, to December 21, 2012 (mean [SD] age, 53 [15] years; 381 men [62%]). In 75 patients (12%), reported maximal LV wall thickness was identical between MRI and TTE. Median difference in reported maximal LV wall thickness between the techniques was 3 mm (maximum difference, 17 mm). Of the 63 patients with ≥1 technique measuring maximal LV wall thickness ≥30 mm, 44 patients (70%) had discrepant classification regarding massive hypertrophy. MRI identified 52 patients (83%) with massive hypertrophy; TTE, 30 patients (48%). Although guidelines recommend MRI or TTE imaging to assess cardiac anatomy in HC, this study shows discrepancy between the techniques for maximal reported LV wall thickness assessment. In conclusion, because this measure clinically affects prognosis and therapeutic decision making, efforts to resolve these discrepancies are critical. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. How best to assess suppression in patients with high anisometropia.

    PubMed

    Li, Jinrong; Hess, Robert F; Chan, Lily Y L; Deng, Daming; Chen, Xiang; Yu, Minbin; Thompson, Benjamin S

    2013-02-01

    We have recently described a rapid technique for measuring suppression using a dichoptic signal/noise task. Here, we report a modification of this technique that allows for accurate measurements to be made in amblyopic patients with high levels of anisometropia. This was necessary because aniseikonic image size differences between the two eyes can provide a cue for signal/noise segregation and, therefore, influence suppression measurement in these patients. Suppression was measured using our original technique and with a modified technique whereby the size of the signal and noise elements was randomized across the stimulus to eliminate size differences as a cue for task performance. Eleven patients with anisometropic amblyopia, five with more than 5 diopters (D) spherical equivalent difference (SED), six with less than 5 D SED between the eyes, and 10 control observers completed suppression measurements using both techniques. Suppression measurements in controls and patients with less than 5 D SED were constant across the two techniques; however, patients with more than 5 D SED showed significantly stronger suppression on the modified technique with randomized element size. Measurements made with the modified technique correlated with the loss of visual acuity in the amblyopic eye and were in good agreement with previous reports using detailed psychophysical measurements. The signal/noise technique for measuring suppression can be applied to patients with high levels of anisometropia and aniseikonia if element size is randomized. In addition, deeper suppression is associated with a greater loss of visual acuity in patients with anisometropic amblyopia.

  7. DURIP: Super-Resolution Module for Confocal Microscopy of Reconfigurable Matter

    DTIC Science & Technology

    2014-09-28

    Research Office P.O. Box 12211 Research Triangle Park, NC 27709-2211 superresolution microscopy, colloidal particles, self-assembly REPORT...previously have been resolved by optical microscopy. Results of Super Resolution Technique Evaluation Commercially available superresolution imaging...Weaknesses of the method are that is fundamentally a measurement that can only be deployed for fixed samples. Because superresolution is obtained by

  8. Soft materials with recoverable shape factors from extreme distortion states

    DOE PAGES

    Goff, Jonathan; Sulaiman, Santy; Arkles, Barry; ...

    2016-01-20

    We present elastomeric polysiloxane nanocomposites with elongations of >5000% (more than 3× greater than any previously reported material) with excellent shape recovery. Highly deformable materials are desirable for the fabrication of stretchable implants and microfluidic devices. No crosslinking or domain formation is observed by a variety of analytical techniques, suggesting that their elastomeric behavior is caused by polymer chain entanglements.

  9. Understanding Thermal Transport in Graded, Layered and Hybrid Materials

    DTIC Science & Technology

    2014-04-01

    interfacial chemistries, including metallic and carbide layers, and; (iv) mimic the observed interface structure on a TDTR specimen by manipulating the...surface carbides , which were extracted from several different composites via acid dissolution of Cu, continued throughout the last 12 months of the...effort. The previously-reported electron probe microanalysis (EPMA) based techniques were employed to estimate the interfacial carbide layer thickness

  10. Use of a tubed pectoralis major myocutaneous flap for salvage of a failed colonic bypass of the esophagus.

    PubMed

    Doberneck, R C; Oschwald, D L; Orgel, M G

    1986-05-01

    The use of tube PMCF as salvage for a failed colon bypass of the esophagus has not been described previously. The present report describes the technique and successful use of a tubed PMCF as a solution to the problem of a failed cervical anastomosis after colon bypass of a long distal esophageal stricture.

  11. UK Health-Care Professionals' Experience of On-Line Learning Techniques: A Systematic Review of Qualitative Data

    ERIC Educational Resources Information Center

    Carroll, Christopher; Booth, Andrew; Papaioannou, Diana; Sutton, Anthea; Wong, Ruth

    2009-01-01

    Introduction: Continuing professional development and education is vital to the provision of better health services and outcomes. The aim of this study is to contribute to the evidence base by performing a systematic review of qualitative data from studies reporting health professionals' experience of e-learning. No such previous review has been…

  12. Humeral windows in revision total elbow arthroplasty.

    PubMed

    Peach, Chris A; Salama, Amir; Stanley, David

    2016-04-01

    The use of cortical windows for revision elbow arthroplasty has not previously been widely reported. Their use aids safe revision of a well fixed humeral prosthesis and can be used in the setting of dislocation, periprosthetic fracture or aseptic loosening of the ulnar component. We describe our technique and results of cortical windows in the distal humerus for revision elbow arthroplasty surgery.

  13. The Extraordinary Nature of Barney's Drumming: A Complementary Study of Ordinary Noise Making in Chimpanzees.

    PubMed

    Dufour, Valérie; Pasquaretta, Cristian; Gayet, Pierre; Sterck, Elisabeth H M

    2017-01-01

    In a previous study (Dufour et al., 2015) we reported the unusual characteristics of the drumming performance of a chimpanzee named Barney. His sound production, several sequences of repeated drumming on an up-turned plastic barrel, shared features typical for human musical drumming: it was rhythmical, decontextualized, and well controlled by the chimpanzee. This type of performance raises questions about the origins of our musicality. Here we recorded spontaneously occurring events of sound production with objects in Barney's colony. First we collected data on the duration of sound making. Here we examined whether (i) the context in which objects were used for sound production, (ii) the sex of the producer, (iii) the medium, and (iv) the technique used for sound production had any effect on the duration of sound making. Interestingly, duration of drumming differed across contexts, sex, and techniques. Then we filmed as many events as possible to increase our chances of recording sequences that would be musically similar to Barney's performance in the original study. We filmed several long productions that were rhythmically interesting. However, none fully met the criteria of musical sound production, as previously reported for Barney.

  14. The Extraordinary Nature of Barney's Drumming: A Complementary Study of Ordinary Noise Making in Chimpanzees

    PubMed Central

    Dufour, Valérie; Pasquaretta, Cristian; Gayet, Pierre; Sterck, Elisabeth H. M.

    2017-01-01

    In a previous study (Dufour et al., 2015) we reported the unusual characteristics of the drumming performance of a chimpanzee named Barney. His sound production, several sequences of repeated drumming on an up-turned plastic barrel, shared features typical for human musical drumming: it was rhythmical, decontextualized, and well controlled by the chimpanzee. This type of performance raises questions about the origins of our musicality. Here we recorded spontaneously occurring events of sound production with objects in Barney's colony. First we collected data on the duration of sound making. Here we examined whether (i) the context in which objects were used for sound production, (ii) the sex of the producer, (iii) the medium, and (iv) the technique used for sound production had any effect on the duration of sound making. Interestingly, duration of drumming differed across contexts, sex, and techniques. Then we filmed as many events as possible to increase our chances of recording sequences that would be musically similar to Barney's performance in the original study. We filmed several long productions that were rhythmically interesting. However, none fully met the criteria of musical sound production, as previously reported for Barney. PMID:28154521

  15. Imported dengue from 2013 Angola outbreak: Not just serotype 1 was detected.

    PubMed

    Abreu, Cândida; Silva-Pinto, André; Lazzara, Daniela; Sobrinho-Simões, Joana; Guimarães, João Tiago; Sarmento, António

    2016-06-01

    All the reports from Angola's 2013 dengue outbreak revealed serotype 1. However, previously dengue serotypes 1-4 have been reported in Africa and in 2014 serotype 4 was reported in Angola. To report dengue serotypes in patients returning from Angola during 2013 outbreak. Retrospective, cross-sectional study. We serotyped the dengue by an in house Polymerase Chain Reaction technique in randomly selected cases. From the 2013 Angola's dengue outbreak we treated 47 adult patients. None had history of past dengue. A combo kit test for dengue revealed positive NS1 antigen in 39 and IgM antibodies in 8. From 17 randomly patients tested by RNA Real Time-PCR, 11 were positive: 7 for DENV-1, 2 for DENV-2, 1 for DENV-3 (co-infected with DENV-1) and 1 for DENV-4. None had a complicated or fatal evolution. Unlike previous reports the 4 serotypes were detected, and this resulted in a different epidemiological situation, raising the risk of future outbreaks of severe dengue. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Correction for intravascular activity in the oxygen-15 steady-state technique is independent of the regional hematocrit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lammertsma, A.A.; Baron, J.C.; Jones, T.

    1987-06-01

    The oxygen-15 steady-state technique to measure the regional cerebral metabolic rate for oxygen requires a correction for the nonextracted intravascular molecular oxygen-15. To perform this correction, an additional procedure is carried out using RBCs labeled with /sup 11/CO or C/sup 15/O. The previously reported correction method, however, required knowledge of the regional cerebral to large vessel hematocrit ratio. A closer examination of the underlying model eliminated this ratio. Both molecular oxygen and carbon monoxide are carried by RBCs and are therefore similarly affected by a change in hematocrit.

  17. Applications of asynoptic space - Time Fourier transform methods to scanning satellite measurements

    NASA Technical Reports Server (NTRS)

    Lait, Leslie R.; Stanford, John L.

    1988-01-01

    A method proposed by Salby (1982) for computing the zonal space-time Fourier transform of asynoptically acquired satellite data is discussed. The method and its relationship to other techniques are briefly described, and possible problems in applying it to real data are outlined. Examples of results obtained using this technique are given which demonstrate its sensitivity to small-amplitude signals. A number of waves are found which have previously been observed as well as two not heretofore reported. A possible extension of the method which could increase temporal and longitudinal resolution is described.

  18. Histologic morphometry confirms a prophylactic effect for hyperbaric oxygen in the prevention of delayed radiation enteropathy.

    PubMed

    Feldmeier, J J; Davolt, D A; Court, W S; Onoda, J M; Alecu, R

    1998-01-01

    In a previous publication (Feldmeier et al., Radiother Oncol 1995; 35:138-144) we reported our success in preventing delayed radiation enteropathy in a murine model by the application of hyperbaric oxygen (HBO2). In this study we introduce a histologic morphometric technique for assessing fibrosis in the submucosa of these same animal specimens and relate this assay to the previous results. The histologic morphometry, like the previous gross morphometry and compliance assays, demonstrates a significant protective effect for HBO2. The present assay is related to the previous assays in a statistically significant fashion. The predictive value for the histologic morphometric assay demonstrates a sensitivity of 75% and a specificity of 62.5%. The applicability of this assay to other organ systems and its potential superiority to the compliance assay are discussed.

  19. Rupture after Previous Endovascular Aneurysm Repair due to Type IA Endoleak: Complete Endograft Preservation Is Feasible with Proximal Suturing, Aortic Neck Banding, and Sac Plication.

    PubMed

    Karkos, Christos D; Mitka, Maria; Pliatsios, Ioannis; Xanthopoulou, Efthalia; Giagtzidis, Ioakeim T; Papadimitriou, Christina T; Papazoglou, Konstantinos O

    2018-05-01

    Rupture of an abdominal aortic aneurysm (AAA) after previous endovascular repair (EVAR) may require endograft explantation and replacement with a prosthetic surgical graft. Recent reports have suggested that total endograft removal during late surgical conversion in the nonruptured setting may not be necessary and that preserving functional parts of the endograft may improve results. Similar techniques may be used for ruptured cases diminishing the magnitude of an already difficult and complex procedure. We describe the successful treatment of a ruptured AAA after previous EVAR with complete endograft preservation by combining transmural endograft fixation with sutures, proximal aortic neck banding, and sac plication. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Variable Coupling Scheme for High Frequency Electron Spin Resonance Resonators Using Asymmetric Meshes

    PubMed Central

    Tipikin, D. S.; Earle, K. A.; Freed, J. H.

    2010-01-01

    The sensitivity of a high frequency electron spin resonance (ESR) spectrometer depends strongly on the structure used to couple the incident millimeter wave to the sample that generates the ESR signal. Subsequent coupling of the ESR signal to the detection arm of the spectrometer is also a crucial consideration for achieving high spectrometer sensitivity. In previous work, we found that a means for continuously varying the coupling was necessary for attaining high sensitivity reliably and reproducibly. We report here on a novel asymmetric mesh structure that achieves continuously variable coupling by rotating the mesh in its own plane about the millimeter wave transmission line optical axis. We quantify the performance of this device with nitroxide spin-label spectra in both a lossy aqueous solution and a low loss solid state system. These two systems have very different coupling requirements and are representative of the range of coupling achievable with this technique. Lossy systems in particular are a demanding test of the achievable sensitivity and allow us to assess the suitability of this approach for applying high frequency ESR to the study of biological systems at physiological conditions, for example. The variable coupling technique reported on here allows us to readily achieve a factor of ca. 7 improvement in signal to noise at 170 GHz and a factor of ca. 5 at 95 GHz over what has previously been reported for lossy samples. PMID:20458356

  1. Local bone graft harvesting and volumes in posterolateral lumbar fusion: a technical report.

    PubMed

    Carragee, Eugene J; Comer, Garet C; Smith, Micah W

    2011-06-01

    In lumbar surgery, local bone graft is often harvested and used in posterolateral fusion procedures. The volume of local bone graft available for posterolateral fusion has not been determined in North American patients. Some authors have described this as minimal, but others have suggested the volume was sufficient to be reliably used as a stand-alone bone graft substitute for single-level fusion. To describe the technique used and determine the volume of local bone graft available in a cohort of patients undergoing single-level primary posterolateral fusion by the authors harvesting technique. Technical description and cohort report. Consecutive patients undergoing lumbar posterolateral fusion with or without instrumentation for degenerative processes. Local bone graft volume. Consecutive patients undergoing lumbar posterolateral fusion with or without instrumentation for degenerative processes of were studied. Local bone graft was harvested by a standard method in each patient and the volume measured by a standard procedure. Twenty-five patients were studied, and of these 11 (44%) had a previous decompression. The mean volume of local bone graft harvested was measured to be 25 cc (range, 12-36 cc). Local bone graft was augmented by iliac crest bone in six of 25 patients (24%) if the posterolateral fusion bed was not well packed with local bone alone. There was a trend to greater local bone graft volumes in men and in patients without previous decompression. Large volumes of local bone can be harvested during posterolateral lumbar fusion surgery. Even in patients with previous decompression the volume harvested is similar to that reported harvested from the posterior iliac crest for single-level fusion. Copyright © 2011 Elsevier Inc. All rights reserved.

  2. Image-Subtraction Photometry of Variable Stars in the Globular Clusters NGC 6388 and NGC 6441

    NASA Technical Reports Server (NTRS)

    Corwin, Michael T.; Sumerel, Andrew N.; Pritzl, Barton J.; Smith, Horace A.; Catelan, M.; Sweigart, Allen V.; Stetson, Peter B.

    2006-01-01

    We have applied Alard's image subtraction method (ISIS v2.1) to the observations of the globular clusters NGC 6388 and NGC 6441 previously analyzed using standard photometric techniques (DAOPHOT, ALLFRAME). In this reanalysis of observations obtained at CTIO, besides recovering the variables previously detected on the basis of our ground-based images, we have also been able to recover most of the RR Lyrae variables previously detected only in the analysis of Hubble Space Telescope WFPC2 observations of the inner region of NGC 6441. In addition, we report five possible new variables not found in the analysis of the EST observations of NGC 6441. This dramatically illustrates the capabilities of image subtraction techniques applied to ground-based data to recover variables in extremely crowded fields. We have also detected twelve new variables and six possible variables in NGC 6388 not found in our previous groundbased studies. Revised mean periods for RRab stars in NGC 6388 and NGC 6441 are 0.676 day and 0.756 day, respectively. These values are among the largest known for any galactic globular cluster. Additional probable type II Cepheids were identified in NGC 6388, confirming its status as a metal-rich globular cluster rich in Cepheids.

  3. Uncluttered Single-Image Visualization of Vascular Structures using GPU and Integer Programming

    PubMed Central

    Won, Joong-Ho; Jeon, Yongkweon; Rosenberg, Jarrett; Yoon, Sungroh; Rubin, Geoffrey D.; Napel, Sandy

    2013-01-01

    Direct projection of three-dimensional branching structures, such as networks of cables, blood vessels, or neurons onto a 2D image creates the illusion of intersecting structural parts and creates challenges for understanding and communication. We present a method for visualizing such structures, and demonstrate its utility in visualizing the abdominal aorta and its branches, whose tomographic images might be obtained by computed tomography or magnetic resonance angiography, in a single two-dimensional stylistic image, without overlaps among branches. The visualization method, termed uncluttered single-image visualization (USIV), involves optimization of geometry. This paper proposes a novel optimization technique that utilizes an interesting connection of the optimization problem regarding USIV to the protein structure prediction problem. Adopting the integer linear programming-based formulation for the protein structure prediction problem, we tested the proposed technique using 30 visualizations produced from five patient scans with representative anatomical variants in the abdominal aortic vessel tree. The novel technique can exploit commodity-level parallelism, enabling use of general-purpose graphics processing unit (GPGPU) technology that yields a significant speedup. Comparison of the results with the other optimization technique previously reported elsewhere suggests that, in most aspects, the quality of the visualization is comparable to that of the previous one, with a significant gain in the computation time of the algorithm. PMID:22291148

  4. Food and probiotic strains from the Saccharomyces cerevisiae species as a possible origin of human systemic infections.

    PubMed

    de Llanos, Rosa; Querol, Amparo; Pemán, Javier; Gobernado, Miguel; Fernández-Espinar, María Teresa

    2006-08-01

    We report four cases of blood cultures testing positive for yeast strains belonging to the species Saccharomyces cerevisiae. Using molecular techniques, RFLP of mtDNA and delta-PCR amplification, we show the association of two of the isolates with non-clinical strains. Specifically, with two commercial bread-making strains and the therapeutic S. boulardii strain. The association of S. boulardii with cases of fungemia has been reported previously. Nevertheless, this is the first time that a baker's yeast has been isolated from blood.

  5. Atomic Resonance Radiation Energetics Investigation as a Diagnostic Method for Non-Equilibrium Hypervelocity Flows

    NASA Technical Reports Server (NTRS)

    Meyer, Scott A.; Bershader, Daniel; Sharma, Surendra P.; Deiwert, George S.

    1996-01-01

    Absorption measurements with a tunable vacuum ultraviolet light source have been proposed as a concentration diagnostic for atomic oxygen, and the viability of this technique is assessed in light of recent measurements. The instrumentation, as well as initial calibration measurements, have been reported previously. We report here additional calibration measurements performed to study the resonance broadening line shape for atomic oxygen. The application of this diagnostic is evaluated by considering the range of suitable test conditions and requirements, and by identifying issues that remain to be addressed.

  6. Electroform replication used for multiple X-ray mirror production

    NASA Technical Reports Server (NTRS)

    Kowalski, M. P.; Ulmer, M. P.; Purcell, W. R., Jr.; Loughlin, J. E. A.

    1984-01-01

    The electroforming technique for producing X-ray mirrors is described, and results of X-ray tests performed on copies made from a simple conical mandrel are reported. The design of the mandrel is depicted and the total reflectivity as well as the full-wave half modulation resolution are shown as a function of energy. The reported work has improved on previous studies by providing smaller grazing angles, making measurements at higher energies, producing about four times as many replicas from one mandrel, and obtaining better angular resolution.

  7. Stercoral perforation of the colon proximal to an end colostomy.

    PubMed Central

    Serpell, J. W.; Sen, M.; Giddins, G.; Nicholls, R. J.; Bradfield, W. J.

    1991-01-01

    Stercoral perforation of the colon is rare, and has not previously been reported as a postoperative complication, proximal to an end colostomy. Two such cases are reported; in addition in one the stercoral perforation was recurrent, emphasizing the multifocal nature of the disease. Both cases demonstrate the failure of standard techniques to deal with scybala in the loaded proximal colon. It is, therefore, suggested that intra-operative orthograde colonic lavage is indicated to protect a terminal colostomy from the risk of stercoral perforation in such cases. PMID:2062783

  8. Dissociative and double photoionization of CO from threshold to 90 A

    NASA Technical Reports Server (NTRS)

    Masuoka, T.; Samson, J. A. R.

    1981-01-01

    Partial cross sections for molecular photoionization (CO(+)), dissociative photoionization (C(+) and O(+)), and dissociative double photoionization (C(2+)) in CO have been measured from their thresholds to 90 A using techniques of mass spectrometry. The results are compared with data reported previously. Several peaks observed in the cross section curves for dissociated fragments are tentatively assigned by comparing with those in the photoelectron spectra reported for CO. It is concluded that the shoulder in the total absorption cross section curve between 400 and 90 A results solely from the dissociative ionization processes.

  9. Yokenella regensburgei in an immunocompromised host: a case report and review of the literature.

    PubMed

    Lo, Y-C; Chuang, Y-W; Lin, Y-H

    2011-10-01

    Yokenella regensburgei belongs to the Enterobacteriaceae and shares some biochemical characteristics with Hafnia alvei. A few case reports have suggested that it is an opportunistic pathogen, but there is no strong evidence to support its clinical importance. Until recently, it was difficult to accurately differentiate between Y. regensburgei and H. alvei by use of routine identification techniques. Here, we present a case of soft tissue infection and bacteremia caused by Y. regensburgei, which was successfully treated by intravenous administration of ceftriaxone for three weeks, and review the previous literature.

  10. Concerning the mechanism of the FeCl3-catalyzed alpha-oxyamination of aldehydes: evidence for a non-SOMO activation pathway.

    PubMed

    Van Humbeck, Jeffrey F; Simonovich, Scott P; Knowles, Robert R; MacMillan, David W C

    2010-07-28

    The mechanism of a recently reported aldehyde alpha-oxyamination reaction has been studied using a combination of kinetic, spectrometric, and spectrophotometric techniques. Most crucially, the use of a validated cyclopropane-based radical-clock substrate has demonstrated that carbon-oxygen bond formation occurs predominantly through an enamine activation manifold. The mechanistic details reported herein indicate that, as has been proposed for previously studied alcohol oxidations, complexation between TEMPO and a simple metal salt leads to electrophilic ionic reactivity.

  11. Doppler imaging with dual-detection full-range frequency domain optical coherence tomography

    PubMed Central

    Meemon, Panomsak; Lee, Kye-Sung; Rolland, Jannick P.

    2010-01-01

    Most of full-range techniques for Frequency Domain Optical Coherence Tomography (FD-OCT) reported to date utilize the phase relation between consecutive axial lines to reconstruct a complex interference signal and hence may exhibit degradation in either mirror image suppression performance or detectable velocity dynamic range or both when monitoring a moving sample such as flow activity. We have previously reported a technique of mirror image removal by simultaneous detection of the quadrature components of a complex spectral interference called a Dual-Detection Frequency Domain OCT (DD-FD-OCT) [Opt. Lett. 35, 1058-1060 (2010)]. The technique enables full range imaging without any loss of acquisition speed and is intrinsically less sensitive to phase errors generated by involuntary movements of the subject. In this paper, we demonstrate the application of the DD-FD-OCT to a phase-resolved Doppler imaging without degradation in either mirror image suppression performance or detectable velocity dynamic range that were observed in other full-range Doppler methods. In order to accommodate for Doppler imaging, we have developed a fiber-based DD-FD-OCT that more efficiently utilizes the source power compared with the previous free-space DD-FD-OCT. In addition, the velocity sensitivity of the phase-resolved DD-FD-OCT was investigated, and the relation between the measured Doppler phase shift and set flow velocity of a flow phantom was verified. Finally, we demonstrate the Doppler imaging using the DD-FD-OCT in a biological sample. PMID:21258488

  12. Nondestructive inspection of graphite-epoxy laminates for heat damage using DRIFT and LPF spectroscopies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Powell, G.L.; Smyrl, N.R.; Janke, C.J.

    The effect of heat damage on polymer matrix composites (PMC) used in aircraft structures presents a unique problem for nondestructive testing (ND) in that damage may result as a combination of thermally cycling the PMC above the glass transition temperature of the polymer and oxidative degradation of the polymer or the polymer-fiber interface. The usual techniques for the detection of voids and flaws by radiographic, ultrasonic, and thermal imaging techniques play an important role in this ND problem. However, heat damage may result in loss of strength in these materials without producing physical flaws (cracks and delaminations) big enough tomore » be detected. Diffuse reflectance Fourier transform infrared (DRIFT) and laser pumped fluorescence (LPF) measurements previously obtained on IM6/3501-6 laminate panels were re-evaluated to improve these techniques for the nondestructive inspection of aircraft. A more robust algorithm for relating flexural strength to changes in DRIFT spectra related to oxidation is presented and used to interpret previously reported evacuable cell DRIFT measurements. Recent advances in DRIFT technology are described which include an evacuable cell with a hemispherical window for oxidation kinetics studies, and the development of a portable DRIFT spectrometer that was used to make measurements on an aircraft. The use of a 633-nm helium-neon laser for LPF is reported as a means for rapidly relating both fluorescence intensity and spectral distribution to flexural strength.« less

  13. Distal biceps reconstruction using an Achilles tendon allograft, transosseous EndoButton, and Pulvertaft weave with tendon wrap technique for retracted, irreparable distal biceps ruptures.

    PubMed

    Phadnis, Joideep; Flannery, Olivia; Watts, Adam C

    2016-06-01

    Distal biceps ruptures can result in ongoing pain and weakness when treated nonoperatively. If retraction of the tendon renders primary repair impossible, reconstruction using a graft is recommended. The current literature includes a variety of techniques with studies reporting small patient numbers. The aim of this study was to report the results of a larger cohort of patients using a technique modified from those previously described in the literature. Twenty-one consecutive male patients underwent distal biceps reconstruction through 2 small anterior incisions using an Achilles tendon allograft that was fixed distally using a transosseous EndoButton and secured proximally using a Pulvertaft weave and tendon wrap. The mean age was 44 years, and the mean time to surgery was 25 months (range, 2-96 months). Functional outcomes were collected prospectively. The mean preoperative Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) score (11 patients) was 1.9 (range, 0-4.5). The mean postoperative Oxford Elbow Score, QuickDASH score, and Mayo Elbow Performance Score were 44.7 (range, 35-48), 4 (range, 0-20.5), and 92.9 (range, 70-100), respectively, at a mean follow up of 15 months (range, 6-35 months). The mean postoperative QuickDASH score was significantly improved compared with preoperatively (P < .001). All patients were satisfied and all returned to their previous level of activity. There were 2 transient lateral antebrachial cutaneous nerve paresthesias, and 2 patients had a 5° extension lag. There were no other complications. Achilles allograft reconstruction of retracted irreparable distal biceps ruptures provides consistently good results with few complications using this technique. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  14. [Anesthetic infiltration of the spermatic cord in surgery for voluminous hydrocele].

    PubMed

    Reale, C; Corinti, R; Galullo, B; Borgonuovo, P; Borgonuovo, P

    1998-06-01

    The use of a new technique in spermatic cord block in surgical treatment of large hydroceles is reported. Identification of the cord in these cases is often difficult due to the presence of the hydrocele. The reported technique consists in the percutaneous drainage of the hydrocele prior to the block, in order to allow an easier identification of the cord. The block is then performed by the usual method. 108 patients with large hydroceles (above 250 mls) underwent surgical repair employing this approach. In only one case the cord was not identified even after drainage due to the effects of a previous hernioplasty. In the remaining 107 patients the cord was easily identified and blocked. The excellent results obtained with this approach, show that cord block is possible in all patients, even when a large hydrocele is present.

  15. Physical properties of molten core materials: Zr-Ni and Zr-Cr alloys measured by electrostatic levitation

    NASA Astrophysics Data System (ADS)

    Ohishi, Yuji; Kondo, Toshiki; Ishikawa, Takehiko; Okada, Junpei T.; Watanabe, Yuki; Muta, Hiroaki; Kurosaki, Ken; Yamanaka, Shinsuke

    2017-03-01

    It is important to understand the behaviors of molten core materials to investigate the progression of a core meltdown accident. In the early stages of bundle degradation, low-melting-temperature liquid phases are expected to form via the eutectic reaction between Zircaloy and stainless steel. The main component of Zircaloy is Zr and those of stainless steel are Fe, Ni, and Cr. Our group has previously reported physical property data such as viscosity, density, and surface tension for Zr-Fe liquid alloys using an electrostatic levitation technique. In this study, we report the viscosity, density, and surface tension of Zr-Ni and Zr-Cr liquid alloys (Zr1-xNix (x = 0.12 and 0.24) and Zr0.77Cr0.23) using the electrostatic levitation technique.

  16. A Multi-Camera System for Bioluminescence Tomography in Preclinical Oncology Research

    PubMed Central

    Lewis, Matthew A.; Richer, Edmond; Slavine, Nikolai V.; Kodibagkar, Vikram D.; Soesbe, Todd C.; Antich, Peter P.; Mason, Ralph P.

    2013-01-01

    Bioluminescent imaging (BLI) of cells expressing luciferase is a valuable noninvasive technique for investigating molecular events and tumor dynamics in the living animal. Current usage is often limited to planar imaging, but tomographic imaging can enhance the usefulness of this technique in quantitative biomedical studies by allowing accurate determination of tumor size and attribution of the emitted light to a specific organ or tissue. Bioluminescence tomography based on a single camera with source rotation or mirrors to provide additional views has previously been reported. We report here in vivo studies using a novel approach with multiple rotating cameras that, when combined with image reconstruction software, provides the desired representation of point source metastases and other small lesions. Comparison with MRI validated the ability to detect lung tumor colonization in mouse lung. PMID:26824926

  17. Unilateral cleft lip and palate: Simultaneous early repair of the nose, anterior palate and lip

    PubMed Central

    Laberge, Louise Caouette

    2007-01-01

    Unilateral cleft lip and palate is a defect involving the lip, nose and maxilla. These structures are inter-related, and simultaneous early correction of all the aspects of the defect is necessary to obtain a satisfactory result that will be maintained with growth. The surgical technique combining various procedures is presented and compared with previously published reports. PMID:19554125

  18. Use of digital image correlation to study the local deformation field of paper and paperboard

    Treesearch

    J.M. Considine; C.T. Scott; R. Gleisner; J.Y. Zhu

    2005-01-01

    Digital image correlation was used to measure the full-field deformation of paperboard and handsheet tensile specimens. The correlation technique was able to accurately measure strain in regions 0.6 by 0.6 mm. Results showed the variation of strain to be much larger than has been previously reported. For machine made paperboard tested in the cross-direction, the...

  19. Proceedings of the second United Nations symposium on the development and use of geothermal resources. Volume 2 (in several languages)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    Separate abstracts were prepared for 69 of the 77 papers presented. The remaining 7 papers were previously abstracted in ERA and can be found in the report number index under CONF-750525. The papers presented are under sections entitled geophysical techniques in exploration, environmental factors and waste disposal, and drilling technology. (WHK)

  20. Maximizing the Predictive Value of Production Rules

    DTIC Science & Technology

    1988-08-31

    Clancev, 1985] Clancey, W. "Heuristic Classification." Artifcial Intelligence . 27 (1985) 289-350. [Crawford, 19881 Crawford, S. "Extensions to the CART...Optimality 16 6.1.2. Comparative Analysis for Normally Distributed Data 17 6.2. Comparison with Alternative Machine Learning Methods 18 6.2.1. Alternative...are reported on data sets previously analyzed in the Al literature using alternative classification techniques. 1. Introduction MIanv decision-making

  1. Evaluation of Methodology for Estimating the Cost of Air Force On-The-Job Training. Final Report.

    ERIC Educational Resources Information Center

    Samers, Bernard N.; And Others

    Described is the final phase of a study directed at the development of an on-the-job training (OJT) costing methodology. Utilizing a modification of survey techniques tested and evaluated during the previous phase, estimates were obtained for the cost of OJT for airman training from the l-level (unskilled to the 3-level (semiskilled) in five…

  2. Break-technique handheld dynamometry: relation between angular velocity and strength measurements.

    PubMed

    Burns, Stephen P; Spanier, David E

    2005-07-01

    To determine whether the muscle strength, as measured with break-technique handheld dynamometry (HHD), is dependent on the angular velocity achieved during testing and to compare reliability at different angular velocities. Repeated-measures study. Participants underwent HHD by using make-technique (isometric) and break-technique (eccentric) dynamometry at 3 prespecified angular velocities. Elbow movement was recorded with an electrogoniometer. Inpatient spinal cord injury unit. Convenience sample of 20 persons with tetraplegia with weakness of elbow flexors or extensors. Not applicable. Elbow angular velocity and muscle strength recorded during HHD. With the break technique, angular velocities averaging 15 degrees , 33 degrees , and 55 degrees /s produced 16%, 30%, and 51% greater strength measurements, respectively, than velocities recorded by using the make technique (all P < .006 for comparisons between successive techniques). The intraclass correlation coefficient for intrarater reliability was .89 or greater for all testing techniques. Greater strength is recorded with faster angular velocities during HHD. Differences in angular velocity may explain the wide range previously reported for break- versus make-technique strength measurements. Variation in angular velocity is a potential source of variability in serial HHD strength measurements, and for this reason the make technique may be preferable.

  3. High speed wavefront sensorless aberration correction in digital micromirror based confocal microscopy.

    PubMed

    Pozzi, P; Wilding, D; Soloviev, O; Verstraete, H; Bliek, L; Vdovin, G; Verhaegen, M

    2017-01-23

    The quality of fluorescence microscopy images is often impaired by the presence of sample induced optical aberrations. Adaptive optical elements such as deformable mirrors or spatial light modulators can be used to correct aberrations. However, previously reported techniques either require special sample preparation, or time consuming optimization procedures for the correction of static aberrations. This paper reports a technique for optical sectioning fluorescence microscopy capable of correcting dynamic aberrations in any fluorescent sample during the acquisition. This is achieved by implementing adaptive optics in a non conventional confocal microscopy setup, with multiple programmable confocal apertures, in which out of focus light can be separately detected, and used to optimize the correction performance with a sampling frequency an order of magnitude faster than the imaging rate of the system. The paper reports results comparing the correction performances to traditional image optimization algorithms, and demonstrates how the system can compensate for dynamic changes in the aberrations, such as those introduced during a focal stack acquisition though a thick sample.

  4. Primary Ewing's sarcoma of vulva: a case report and a review of the literature.

    PubMed

    Che, Shao-Min; Cao, Pei-Long; Chen, Hong-Wei; Liu, Zi; Meng, Du

    2013-03-01

    Ewing sarcomas/peripheral primitive neuroectodermal tumors (ES/pPNET) are extremely rare in the vulva. A review of the literature reveals only 14 previously reported possible cases. Here we reported a case of primary extraskeletal Ewing's sarcoma (EES) of the vulva in a 37-year-old woman. Characteristic histologic features of ES/pPNET were present in this case, including a monomorphic population of small round blue cells with cytoplasmic glycogen confirmed by periodic acid-Schiff, membrane staining with CD99 and nuclear staining with FLI-1. After surgery, the patient was found to have pulmonary metastasis and then received six cycles of polychemotherapy. She is still alive with stable disease after 1 year of follow up. Our findings underline the crucial role of immunohistochemical techniques in the differential diagnosis of small round cell tumors in these unusual locations. We also give a summary about the clinical and pathological features of the primary ES/pPNET in the vulva reported previously in the literature. © 2012 The Authors. Journal of Obstetrics and Gynaecology Research © 2012 Japan Society of Obstetrics and Gynecology.

  5. Explosively driven hypervelocity launcher: Second-stage augmentation techniques

    NASA Technical Reports Server (NTRS)

    Baum, D. W.

    1973-01-01

    The results are described of a continuing study aimed at developing a two-stage explosively driven hypervelocity launcher capable of achieving projectile velocities between 15 and 20 km/sec. The testing and evaluation of a new cylindrical impact technique for collapsing the barrel of two-stage launcher are reported. Previous two-stage launchers have been limited in ultimate performance by incomplete barrel collapse behind the projectile. The cylindrical impact technique explosively collapses a steel tube concentric with and surrounding the barrel of the launcher. The impact of the tube on the barrel produces extremely high stresses which cause the barrel to collapse. The collapse rate can be adjusted by appropriate variation of the explosive charge and tubing parameters. Launcher experiments demonstrated that the technique did achieve complete barrel collapse and form a second-stage piston. However, jetting occurred in the barrel collapse process and was responsible for severe projectile damage.

  6. Techniques for obtaining regional radiation budgets from satellite radiometer observations, phase 4 and phase 5. Ph.D. Thesis. Final Report

    NASA Technical Reports Server (NTRS)

    Pina, J. F.; House, F. B.

    1976-01-01

    A scheme was developed which divides the earth-atmosphere system into 2060 elemental areas. The regions previously described are defined in terms of these elemental areas which are fixed in size and position as the satellite moves. One method, termed the instantaneous technique, yields values of the radiant emittance (We) and the radiant reflectance (Wr) which the regions have during the time interval of a single satellite pass. The number of observations matches the number of regions under study and a unique solution is obtained using matrix inversion. The other method (termed the best fit technique), yields time averages of We and Wr for large time intervals (e.g., months, seasons). The number of observations in this technique is much greater than the number of regions considered, and an approximate solution is obtained by the method of least squares.

  7. Electrochemical Nanoparticle Sizing Via Nano-Impacts: How Large a Nanoparticle Can be Measured?

    PubMed Central

    Bartlett, Thomas R; Sokolov, Stanislav V; Compton, Richard G

    2015-01-01

    The field of nanoparticle (NP) sizing encompasses a wide array of techniques, with electron microscopy and dynamic light scattering (DLS) having become the established methods for NP quantification; however, these techniques are not always applicable. A new and rapidly developing method that addresses the limitations of these techniques is the electrochemical detection of NPs in solution. The ‘nano-impacts’ technique is an excellent and qualitative in situ method for nanoparticle characterization. Two complementary studies on silver and silver bromide nanoparticles (NPs) were used to assess the large radius limit of the nano-impact method for NP sizing. Noting that by definition a NP cannot be larger than 100 nm in diameter, we have shown that the method quantitatively sizes at the largest limit, the lower limit having been previously reported as ∼6 nm.1 PMID:26491639

  8. Jailed double-microcatheter technique following horizontal stenting for coil embolization of intracranial wide-necked bifurcation aneurysms: A technical report of two cases.

    PubMed

    Kitahara, Takahiro; Hatano, Taketo; Hayase, Makoto; Hattori, Etsuko; Miyakoshi, Akinori; Nakamura, Takehiko

    2017-04-01

    The horizontal stenting technique facilitates endovascular treatment of wide-necked bifurcation intracranial aneurysms. Previous literature shows, however, that subsequent coil embolization at initial treatment results in incomplete obliteration in many cases. The authors present two consecutive cases of wide-necked large bifurcation aneurysms to describe an additional coil embolization technique following horizontal stenting. The patients were a 53-year-old female with an unruptured internal carotid artery terminus aneurysm and a 57-year-old female with a recurrent basilar artery tip aneurysm. Both patients underwent endovascular treatment with horizontal stenting followed by coil embolization with jailed double-microcatheters. Immediate complete obliteration was achieved with no complications, and no recanalization was observed at the one-year follow-up in both cases. Coil embolization with jailed double-microcatheter technique following horizontal stenting is a safe and effective strategy for wide-necked bifurcation aneurysms.

  9. Applying Sequential Analytic Methods to Self-Reported Information to Anticipate Care Needs.

    PubMed

    Bayliss, Elizabeth A; Powers, J David; Ellis, Jennifer L; Barrow, Jennifer C; Strobel, MaryJo; Beck, Arne

    2016-01-01

    Identifying care needs for newly enrolled or newly insured individuals is important under the Affordable Care Act. Systematically collected patient-reported information can potentially identify subgroups with specific care needs prior to service use. We conducted a retrospective cohort investigation of 6,047 individuals who completed a 10-question needs assessment upon initial enrollment in Kaiser Permanente Colorado (KPCO), a not-for-profit integrated delivery system, through the Colorado State Individual Exchange. We used responses from the Brief Health Questionnaire (BHQ), to develop a predictive model for cost for receiving care in the top 25 percent, then applied cluster analytic techniques to identify different high-cost subpopulations. Per-member, per-month cost was measured from 6 to 12 months following BHQ response. BHQ responses significantly predictive of high-cost care included self-reported health status, functional limitations, medication use, presence of 0-4 chronic conditions, self-reported emergency department (ED) use during the prior year, and lack of prior insurance. Age, gender, and deductible-based insurance product were also predictive. The largest possible range of predicted probabilities of being in the top 25 percent of cost was 3.5 percent to 96.4 percent. Within the top cost quartile, examples of potentially actionable clusters of patients included those with high morbidity, prior utilization, depression risk and financial constraints; those with high morbidity, previously uninsured individuals with few financial constraints; and relatively healthy, previously insured individuals with medication needs. Applying sequential predictive modeling and cluster analytic techniques to patient-reported information can identify subgroups of individuals within heterogeneous populations who may benefit from specific interventions to optimize initial care delivery.

  10. Development and Application of Agglomerated Multigrid Methods for Complex Geometries

    NASA Technical Reports Server (NTRS)

    Nishikawa, Hiroaki; Diskin, Boris; Thomas, James L.

    2010-01-01

    We report progress in the development of agglomerated multigrid techniques for fully un- structured grids in three dimensions, building upon two previous studies focused on efficiently solving a model diffusion equation. We demonstrate a robust fully-coarsened agglomerated multigrid technique for 3D complex geometries, incorporating the following key developments: consistent and stable coarse-grid discretizations, a hierarchical agglomeration scheme, and line-agglomeration/relaxation using prismatic-cell discretizations in the highly-stretched grid regions. A signi cant speed-up in computer time is demonstrated for a model diffusion problem, the Euler equations, and the Reynolds-averaged Navier-Stokes equations for 3D realistic complex geometries.

  11. Laser balancing system for high material removal rates

    NASA Technical Reports Server (NTRS)

    Jones, M. G.; Georgalas, G.; Ortiz, A. L.

    1984-01-01

    A laser technique to remove material in excess of 10 mg/sec from a spinning rotor is described. This material removal rate is 20 times greater than previously reported for a surface speed of 30 m/sec. Material removal enhancement was achieved by steering a focused laser beam with moving optics to increase the time of laser energy interaction with a particular location on the circumferential surface of a spinning rotor. A neodymium:yttrium aluminum garnet (Nd:YAG) pulse laser was used in this work to evaluate material removal for carbon steel, 347 stainless steel, Inconal 718, and titanium 6-4. This technique is applicable to dynamic laser balancing.

  12. The Subfascial Approach to Primary and Secondary Breast Augmentation with Autologous Fat Grafting and Form-Stable Implants.

    PubMed

    Sampaio Goes, João Carlos; Munhoz, Alexandre Mendonça; Gemperli, Rolf

    2015-10-01

    This article presents an overview of the subfascial approach to primary and secondary breast augmentation with form-stable implants associated with autologous fat grafting. Although breast augmentation is a well-studied procedure, there are few previous reports concerning the subfascial technique and, especially, this technique associated with lipofilling. Consequently, the authors present their experience with a form-stable, anatomically shaped silicone gel breast implant, which has recently been approved in the United States following FDA clinical trials. Primary and secondary breast augmentations using form-stable implants resulted in satisfactory outcomes. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Quantum key distribution with 1.25 Gbps clock synchronization.

    PubMed

    Bienfang, J; Gross, A; Mink, A; Hershman, B; Nakassis, A; Tang, X; Lu, R; Su, D; Clark, Charles; Williams, Carl; Hagley, E; Wen, Jesse

    2004-05-03

    We have demonstrated the exchange of sifted quantum cryptographic key over a 730 meter free-space link at rates of up to 1.0 Mbps, two orders of magnitude faster than previously reported results. A classical channel at 1550 nm operates in parallel with a quantum channel at 845 nm. Clock recovery techniques on the classical channel at 1.25 Gbps enable quantum transmission at up to the clock rate. System performance is currently limited by the timing resolution of our silicon avalanche photodiode detectors. With improved detector resolution, our technique will yield another order of magnitude increase in performance, with existing technology.

  14. Improvement to the scanning electron microscope image adaptive Canny optimization colorization by pseudo-mapping.

    PubMed

    Lo, T Y; Sim, K S; Tso, C P; Nia, M E

    2014-01-01

    An improvement to the previously proposed adaptive Canny optimization technique for scanning electron microscope image colorization is reported. The additional feature, called pseudo-mapping technique, is that the grayscale markings are temporarily mapped to a set of pre-defined pseudo-color map as a mean to instill color information for grayscale colors in chrominance channels. This allows the presence of grayscale markings to be identified; hence optimization colorization of grayscale colors is made possible. This additional feature enhances the flexibility of scanning electron microscope image colorization by providing wider range of possible color enhancement. Furthermore, the nature of this technique also allows users to adjust the luminance intensities of selected region from the original image within certain extent. © 2014 Wiley Periodicals, Inc.

  15. Shock timing measurements and analysis in deuterium-tritium-ice layered capsule implosions on NIF

    NASA Astrophysics Data System (ADS)

    Robey, H. F.; Celliers, P. M.; Moody, J. D.; Sater, J.; Parham, T.; Kozioziemski, B.; Dylla-Spears, R.; Ross, J. S.; LePape, S.; Ralph, J. E.; Hohenberger, M.; Dewald, E. L.; Berzak Hopkins, L.; Kroll, J. J.; Yoxall, B. E.; Hamza, A. V.; Boehly, T. R.; Nikroo, A.; Landen, O. L.; Edwards, M. J.

    2014-02-01

    Recent advances in shock timing experiments and analysis techniques now enable shock measurements to be performed in cryogenic deuterium-tritium (DT) ice layered capsule implosions on the National Ignition Facility (NIF). Previous measurements of shock timing in inertial confinement fusion implosions [Boehly et al., Phys. Rev. Lett. 106, 195005 (2011); Robey et al., Phys. Rev. Lett. 108, 215004 (2012)] were performed in surrogate targets, where the solid DT ice shell and central DT gas were replaced with a continuous liquid deuterium (D2) fill. These previous experiments pose two surrogacy issues: a material surrogacy due to the difference of species (D2 vs. DT) and densities of the materials used and a geometric surrogacy due to presence of an additional interface (ice/gas) previously absent in the liquid-filled targets. This report presents experimental data and a new analysis method for validating the assumptions underlying this surrogate technique. Comparison of the data with simulation shows good agreement for the timing of the first three shocks, but reveals a considerable discrepancy in the timing of the 4th shock in DT ice layered implosions. Electron preheat is examined as a potential cause of the observed discrepancy in the 4th shock timing.

  16. Pattern-recognition techniques applied to performance monitoring of the DSS 13 34-meter antenna control assembly

    NASA Technical Reports Server (NTRS)

    Mellstrom, J. A.; Smyth, P.

    1991-01-01

    The results of applying pattern recognition techniques to diagnose fault conditions in the pointing system of one of the Deep Space network's large antennas, the DSS 13 34-meter structure, are discussed. A previous article described an experiment whereby a neural network technique was used to identify fault classes by using data obtained from a simulation model of the Deep Space Network (DSN) 70-meter antenna system. Described here is the extension of these classification techniques to the analysis of real data from the field. The general architecture and philosophy of an autonomous monitoring paradigm is described and classification results are discussed and analyzed in this context. Key features of this approach include a probabilistic time-varying context model, the effective integration of signal processing and system identification techniques with pattern recognition algorithms, and the ability to calibrate the system given limited amounts of training data. Reported here are recognition accuracies in the 97 to 98 percent range for the particular fault classes included in the experiments.

  17. Hardware implementation of hierarchical volume subdivision-based elastic registration.

    PubMed

    Dandekar, Omkar; Walimbe, Vivek; Shekhar, Raj

    2006-01-01

    Real-time, elastic and fully automated 3D image registration is critical to the efficiency and effectiveness of many image-guided diagnostic and treatment procedures relying on multimodality image fusion or serial image comparison. True, real-time performance will make many 3D image registration-based techniques clinically viable. Hierarchical volume subdivision-based image registration techniques are inherently faster than most elastic registration techniques, e.g. free-form deformation (FFD)-based techniques, and are more amenable for achieving real-time performance through hardware acceleration. Our group has previously reported an FPGA-based architecture for accelerating FFD-based image registration. In this article we show how our existing architecture can be adapted to support hierarchical volume subdivision-based image registration. A proof-of-concept implementation of the architecture achieved speedups of 100 for elastic registration against an optimized software implementation on a 3.2 GHz Pentium III Xeon workstation. Due to inherent parallel nature of the hierarchical volume subdivision-based image registration techniques further speedup can be achieved by using several computing modules in parallel.

  18. Successful Endoscopic Management of Non-Healing Perforated Duodenal Ulcer with Polyglycolic Acid Sheet and Fibrin Glue.

    PubMed

    Mishiro, Tsuyoshi; Shibagaki, Kotaro; Matsuda, Kayo; Fukuyama, Chika; Okada, Mayumi; Mikami, Hironobu; Izumi, Daisuke; Yamashita, Noritsugu; Okimoto, Eiko; Fukuda, Naoki; Aimi, Masahito; Fukuba, Nobuhiko; Oshima, Naoki; Takanashi, Toshihiro; Matsubara, Takeshi; Ishimura, Norihisa; Ishihara, Shunji; Kinoshita, Yoshikazu

    2016-08-01

    In recent years, treatment techniques in which polyglycolic acid sheets are applied to various situations with fibrin glue have exhibited great clinical potential, and previous studies have reported safety and efficacy. We describe closure of a non-healing perforated duodenal ulcer with the use of a polyglycolic acid sheet and fibrin glue in an elderly patient who was not a candidate for surgery.

  19. DANCING IN THE DARK: NEW BROWN DWARF BINARIES FROM KERNEL PHASE INTERFEROMETRY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pope, Benjamin; Tuthill, Peter; Martinache, Frantz, E-mail: bjsp@physics.usyd.edu.au, E-mail: p.tuthill@physics.usyd.edu.au, E-mail: frantz@naoj.org

    2013-04-20

    This paper revisits a sample of ultracool dwarfs in the solar neighborhood previously observed with the Hubble Space Telescope's NICMOS NIC1 instrument. We have applied a novel high angular resolution data analysis technique based on the extraction and fitting of kernel phases to archival data. This was found to deliver a dramatic improvement over earlier analysis methods, permitting a search for companions down to projected separations of {approx}1 AU on NIC1 snapshot images. We reveal five new close binary candidates and present revised astrometry on previously known binaries, all of which were recovered with the technique. The new candidate binariesmore » have sufficiently close separation to determine dynamical masses in a short-term observing campaign. We also present four marginal detections of objects which may be very close binaries or high-contrast companions. Including only confident detections within 19 pc, we report a binary fraction of at least #Greek Lunate Epsilon Symbol#{sub b} = 17.2{sub -3.7}{sup +5.7}%. The results reported here provide new insights into the population of nearby ultracool binaries, while also offering an incisive case study of the benefits conferred by the kernel phase approach in the recovery of companions within a few resolution elements of the point-spread function core.« less

  20. Physical Examination Reporting System

    PubMed Central

    Rowley, B.A.; Cameron, J.M.; Anderson, D.E.; Nicholas, T.A.; Hogue, R.L.; Hutcheson, J.L.; Peralta, V.H.; Johansen, B.; Walston, D.

    1978-01-01

    The following is a description of a Physical Examination Reporting System which was developed in cooperation with physicians from the Department of Family Practice and the Department of Preventive Medicine, Texas Tech University School of Medicine, Lubbock, Texas. This system was designed to evaluate what effect such a report would have on the practice of medicine in underserved areas with regard to health benefit, medical impact, and economic impact. The set of observations was assembled over a three month period by utilizing techniques previously developed in this area as well as the expertise of the TTUSM faculty. This system was developed for impact evaluation purposes. Its actual daily use may require changes in the form, in method of entry, and in format of the report.

  1. Vadose Zone Transport Field Study: Status Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gee, Glendon W.; Ward, Anderson L.

    2001-11-30

    Studies were initiated at the Hanford Site to evaluate the process controlling the transport of fluids in the vadose zone and to develop a reliable database upon which vadose-zone transport models can be calibrated. These models are needed to evaluate contaminant migration through the vadose zone to underlying groundwaters at Hanford. A study site that had previously been extensively characterized using geophysical monitoring techniques was selected in the 200 E Area. Techniques used previously included neutron probe for water content, spectral gamma logging for radionuclide tracers, and gamma scattering for wet bulk density. Building on the characterization efforts of themore » past 20 years, the site was instrumented to facilitate the comparison of nine vadose-zone characterization methods: advanced tensiometers, neutron probe, electrical resistance tomography (ERT), high-resolution resistivity (HRR), electromagnetic induction imaging (EMI), cross-borehole radar (XBR), and cross-borehole seismic (XBS). Soil coring was used to obtain soil samples for analyzing ionic and isotopic tracers.« less

  2. Measurement of replication structures at the nanometer scale using super-resolution light microscopy

    PubMed Central

    Baddeley, D.; Chagin, V. O.; Schermelleh, L.; Martin, S.; Pombo, A.; Carlton, P. M.; Gahl, A.; Domaing, P.; Birk, U.; Leonhardt, H.; Cremer, C.; Cardoso, M. C.

    2010-01-01

    DNA replication, similar to other cellular processes, occurs within dynamic macromolecular structures. Any comprehensive understanding ultimately requires quantitative data to establish and test models of genome duplication. We used two different super-resolution light microscopy techniques to directly measure and compare the size and numbers of replication foci in mammalian cells. This analysis showed that replication foci vary in size from 210 nm down to 40 nm. Remarkably, spatially modulated illumination (SMI) and 3D-structured illumination microscopy (3D-SIM) both showed an average size of 125 nm that was conserved throughout S-phase and independent of the labeling method, suggesting a basic unit of genome duplication. Interestingly, the improved optical 3D resolution identified 3- to 5-fold more distinct replication foci than previously reported. These results show that optical nanoscopy techniques enable accurate measurements of cellular structures at a level previously achieved only by electron microscopy and highlight the possibility of high-throughput, multispectral 3D analyses. PMID:19864256

  3. The Dynamics of Glomerular Ultrafiltration in the Rat

    PubMed Central

    Brenner, Barry M.; Troy, Julia L.; Daugharty, Terrance M.

    1971-01-01

    Using a unique strain of Wistar rats endowed with glomeruli situated directly on the renal cortical surface, we measured glomerular capillary pressures using servo-nulling micropipette transducer techniques. Pressures in 12 glomerular capillaries from 7 rats averaged 60 cm H2O, or approximately 50% of mean systemic arterial values. Wave form characteristics for these glomerular capillaries were found to be remarkably similar to those of the central aorta. From similarly direct estimates of hydrostatic pressures in proximal tubules, and colloid osmotic pressures in systemic and efferent arteriolar plasmas, the net driving force for ultrafiltration was calculated. The average value of 14 cm H2O is lower by some two-thirds than the majority of estimates reported previously based on indirect techniques. Single nephron GFR (glomerular filtration rate) was also measured in these rats, thereby permitting calculation of the glomerular capillary ultrafiltration coefficient. The average value of 0.044 nl sec−1 cm H2O−1 glomerulus−1 is at least fourfold greater than previous estimates derived from indirect observations. PMID:5097578

  4. Initial sequence characterization of the rhabdoviruses of squamate reptiles, including a novel rhabdovirus from a caiman lizard (Dracaena guianensis)

    PubMed Central

    Wellehan, James F.X.; Pessier, Allan P.; Archer, Linda L.; Childress, April L.; Jacobson, Elliott R.; Tesh, Robert B.

    2012-01-01

    Rhabdoviruses infect a variety of hosts, including non-avian reptiles. Consensus PCR techniques were used to obtain partial RNA-dependent RNA polymerase gene sequence from five rhabdoviruses of South American lizards; Marco, Chaco, Timbo, Sena Madureira, and a rhabdovirus from a caiman lizard (Dracaena guianensis). The caiman lizard rhabdovirus formed inclusions in erythrocytes, which may be a route for infecting hematophagous insects. This is the first information on behavior of a rhabdovirus in squamates. We also obtained sequence from two rhabdoviruses of Australian lizards, confirming previous Charleville virus sequence and finding that, unlike a previous sequence report but in agreement with serologic reports, Almpiwar virus is clearly distinct from Charleville virus. Bayesian and maximum likelihood phylogenetic analysis revealed that most known rhabdoviruses of squamates cluster in the Almpiwar subgroup. The exception is Marco virus, which is found in the Hart Park group. PMID:22397930

  5. Scintillation efficiency measurement of Na recoils in NaI(Tl) below the DAMA/LIBRA energy threshold

    NASA Astrophysics Data System (ADS)

    Xu, Jingke; Shields, Emily; Calaprice, Frank; Westerdale, Shawn; Froborg, Francis; Suerfu, Burkhant; Alexander, Thomas; Aprahamian, Ani; Back, Henning O.; Casarella, Clark; Fang, Xiao; Gupta, Yogesh K.; Ianni, Aldo; Lamere, Edward; Lippincott, W. Hugh; Liu, Qian; Lyons, Stephanie; Siegl, Kevin; Smith, Mallory; Tan, Wanpeng; Kolk, Bryant Vande

    2015-07-01

    The dark matter interpretation of the DAMA modulation signal depends on the NaI(Tl) scintillation efficiency of nuclear recoils. Previous measurements for Na recoils have large discrepancies, especially in the DAMA/LIBRA modulation energy region. We report a quenching effect measurement of Na recoils in NaI(Tl) from 3 to 52 keVnr, covering the whole DAMA/LIBRA energy region for dark matter-Na scattering interpretations. By using a low-energy, pulsed neutron beam, a double time-of-flight technique, and pulse-shape discrimination methods, we obtained the most accurate measurement of this kind for NaI(Tl) to date. The results differ significantly from the DAMA reported values at low energies but fall between the other previous measurements. We present the implications of the new quenching results for the dark matter interpretation of the DAMA modulation signal.

  6. Scintillation efficiency measurement of Na recoils in NaI(Tl) below the DAMA/LIBRA energy threshold

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, Jingke; Shields, Emily; Calaprice, Frank

    2015-07-01

    The dark matter interpretation of the DAMA modulation signal depends on the NaI(Tl) scintillation efficiency of nuclear recoils. Previous measurements for Na recoils have large discrepancies, especially in the DAMA/LIBRA modulation energy region. We report a quenching effect measurement of Na recoils in NaI(Tl) from 3 to 52 keVnr, covering the whole DAMA/LIBRA energy region for dark matter-Na scattering interpretations. By using a low-energy, pulsed neutron beam, a double time-of-flight technique, and pulse-shape discrimination methods, we obtained the most accurate measurement of this kind for NaI(Tl) to date. The results differ significantly from the DAMA reported values at low energies butmore » fall between the other previous measurements. We present the implications of the new quenching results for the dark matter interpretation of the DAMA modulation signal.« less

  7. Femtosecond Laser Flap Creation for Laser In Situ Keratomileusis in the Setting of Previous Radial Keratotomy.

    PubMed

    Rush, Sloan W; Rush, Ryan B

    2015-01-01

    The aim of the study was to report the outcomes of laser in situ keratomileusis (LASIK) in subjects with previous radial keratotomy (RK) using a novel femtosecond laser setting on a proprietary femtosecond laser platform. This was a retrospective, consecutive chart review of patients at a single private practice institution. The medical records of 16 eyes of 8 subjects who underwent femtosecond-assisted LASIK for consecutive hyperopia after RK were retrospectively reviewed. The preoperative characteristics, intraoperative details, and postoperative outcomes were analyzed. All 16 eyes had successful femtosecond laser flap creation without significant intraoperative or postoperative complications. Uncorrected visual acuity significantly improved postoperatively (P = 0.0142) and remained stable through the final follow-up interval at 9 to 12 months postoperatively. None of the subjects lost any lines of best spectacle-corrected visual acuity in the postoperative period. The novel femtosecond laser technique described in this study can provide a safe and effective method for patients undergoing LASIK after previous RK. Future investigations are required to further validate the findings reported in this study.

  8. Ultraflexible and robust graphene supercapacitors printed on textiles for wearable electronics applications

    NASA Astrophysics Data System (ADS)

    Abdelkader, Amr M.; Karim, Nazmul; Vallés, Cristina; Afroj, Shaila; Novoselov, Kostya S.; Yeates, Stephen G.

    2017-09-01

    Printed graphene supercapacitors have the potential to empower tomorrow’s wearable electronics. We report a solid-state flexible supercapacitor device printed on textiles using graphene oxide ink and a screen-printing technique. After printing, graphene oxide was reduced in situ via a rapid electrochemical method avoiding the use of any reducing reagents that may damage the textile substrates. The printed electrodes exhibited excellent mechanical stability due to the strong interaction between the ink and textile substrate. The unique hierarchical porous structure of the electrodes facilitated ionic diffusion and maximised the surface area available for the electrolyte/active material interface. The obtained device showed outstanding cyclic stability over 10 000 cycles and maintained excellent mechanical flexibility, which is necessary for wearable applications. The simple printing technique is readily scalable and avoids the problems associated with fabricating supercapacitor devices made of conductive yarn, as previously reported in the literature.

  9. Graft downsizing during ex vivo lung perfusion: case report and technical notes.

    PubMed

    Nosotti, M; Rosso, L; Mendogni, P; Tosi, D; Palleschi, A; Righi, I; Froio, S; Valenza, F; Santambrogio, L

    2014-09-01

    Among patients with respiratory insufficiency awaiting lung transplantation, small adult patients have a lower opportunity of receiving size-matched pulmonary grafts, because of the shortage of donors, particularly those of small size. Reducing the size of an oversized graft is one of the methods to increase the donor pool; similarly, ex vivo lung perfusion is an emerging technique aimed toward the same purpose. We describe how we combined the 2 techniques (lobar transplantation plus contralateral nonanatomic graft reduction during ex vivo lung perfusion) to overcome graft shortage in a clinical case. For the 1st time, this case report demonstrates that surgical manipulation during ex vivo lung perfusion does not affect the functional improvement in a lung previously judged to be not suitable for transplantation. The 6-month follow-up results are similar to those of standard bilateral lung transplantation. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Reconstruction of an amputated glans penis with a buccal mucosal graft: case report of a novel technique.

    PubMed

    Aboutaleb, Hamdy

    2014-12-01

    Penile amputation is a rare catastrophe and a serious complication of circumcision. Reconstruction of the glans penis may be indicated following amputation. Our report discusses a novel technique for reconfiguration of an amputated glans penis 1 year after a complicated circumcision. A 2-year-old male infant presented to us with glans penis amputation that had occurred during circumcision 1 year previously. The parents complained of severe meatal stenosis with disfigurement of the penis. Penis length was 3 cm. Complete penile degloving was performed. The distal part of the remaining penis was prepared by removing fibrous tissue. A buccal mucosal graft was applied to the distal part of the penis associated with meatotomy. The use of a buccal mucosal graft is a successful and simple procedure with acceptable cosmetic and functional results for late reconfiguration of the glans penis after amputation when penile size is suitable.

  11. State-of-the-art and dissemination of computational tools for drug-design purposes: a survey among Italian academics and industrial institutions.

    PubMed

    Artese, Anna; Alcaro, Stefano; Moraca, Federica; Reina, Rocco; Ventura, Marzia; Costantino, Gabriele; Beccari, Andrea R; Ortuso, Francesco

    2013-05-01

    During the first edition of the Computationally Driven Drug Discovery meeting, held in November 2011 at Dompé Pharma (L'Aquila, Italy), a questionnaire regarding the diffusion and the use of computational tools for drug-design purposes in both academia and industry was distributed among all participants. This is a follow-up of a previously reported investigation carried out among a few companies in 2007. The new questionnaire implemented five sections dedicated to: research group identification and classification; 18 different computational techniques; software information; hardware data; and economical business considerations. In this article, together with a detailed history of the different computational methods, a statistical analysis of the survey results that enabled the identification of the prevalent computational techniques adopted in drug-design projects is reported and a profile of the computational medicinal chemist currently working in academia and pharmaceutical companies in Italy is highlighted.

  12. Reconstruction of an Amputated Glans Penis With a Buccal Mucosal Graft: Case Report of a Novel Technique

    PubMed Central

    2014-01-01

    Penile amputation is a rare catastrophe and a serious complication of circumcision. Reconstruction of the glans penis may be indicated following amputation. Our report discusses a novel technique for reconfiguration of an amputated glans penis 1 year after a complicated circumcision. A 2-year-old male infant presented to us with glans penis amputation that had occurred during circumcision 1 year previously. The parents complained of severe meatal stenosis with disfigurement of the penis. Penis length was 3 cm. Complete penile degloving was performed. The distal part of the remaining penis was prepared by removing fibrous tissue. A buccal mucosal graft was applied to the distal part of the penis associated with meatotomy. The use of a buccal mucosal graft is a successful and simple procedure with acceptable cosmetic and functional results for late reconfiguration of the glans penis after amputation when penile size is suitable. PMID:25512820

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hou, Huilong; Hamilton, Reginald F., E-mail: rfhamilton@psu.edu; Horn, Mark W.

    NiTi shape memory alloy (SMA) thin films were fabricated using biased target ion beam deposition (BTIBD), which is a new technique for fabricating submicrometer-thick SMA thin films, and the capacity to exhibit shape memory behavior was investigated. The thermally induced shape memory effect (SME) was studied using the wafer curvature method to report the stress-temperature response. The films exhibited the SME in a temperature range above room temperature and a narrow thermal hysteresis with respect to previous reports. To confirm the underlying phase transformation, in situ x-ray diffraction was carried out in the corresponding phase transformation temperature range. The B2more » to R-phase martensitic transformation occurs, and the R-phase transformation is stable with respect to the expected conversion to the B19′ martensite phase. The narrow hysteresis and stable R-phase are rationalized in terms of the unique properties of the BTIBD technique.« less

  14. Generating unstructured nuclear reactor core meshes in parallel

    DOE PAGES

    Jain, Rajeev; Tautges, Timothy J.

    2014-10-24

    Recent advances in supercomputers and parallel solver techniques have enabled users to run large simulations problems using millions of processors. Techniques for multiphysics nuclear reactor core simulations are under active development in several countries. Most of these techniques require large unstructured meshes that can be hard to generate in a standalone desktop computers because of high memory requirements, limited processing power, and other complexities. We have previously reported on a hierarchical lattice-based approach for generating reactor core meshes. Here, we describe efforts to exploit coarse-grained parallelism during reactor assembly and reactor core mesh generation processes. We highlight several reactor coremore » examples including a very high temperature reactor, a full-core model of the Korean MONJU reactor, a ¼ pressurized water reactor core, the fast reactor Experimental Breeder Reactor-II core with a XX09 assembly, and an advanced breeder test reactor core. The times required to generate large mesh models, along with speedups obtained from running these problems in parallel, are reported. A graphical user interface to the tools described here has also been developed.« less

  15. Endoscopic Excision of Supracondylar Humeral Spur for Decompression of the Median Nerve and Brachial Artery.

    PubMed

    Bain, Gregory; Gupta, Prince; Phadnis, Joideep; Singhi, Prahalad K

    2016-02-01

    The humeral supracondylar process and Struthers ligament comprise a relatively rare but well-known anatomic variant. They are usually asymptomatic but may produce clinical symptoms related to compression of the median nerve or brachial artery below the ligament. Previously, surgery has been performed with an open ligament release and supracondylar process excision. This article reports on the use of endoscopic findings and the method of ligament release and process excision. Endoscopy is a minimally invasive technique that provides excellent visualization and enables the surgeon to perform dissection with magnification and precision. It allows the surgeon to introduce open surgical techniques into the depths of the wound in a controlled manner. Because of the dead space created, there is a risk of hematoma formation. Many of the concepts used in open surgery are now being used for endoscopic surgery, and vice versa. The barriers and differences among endoscopic, arthroscopic, and open procedures are being broken down. We report another endoscopic technique, which is part of the ongoing evolution of musculoskeletal surgery.

  16. Characteristics of patients making serious inhaler errors with a dry powder inhaler and association with asthma-related events in a primary care setting

    PubMed Central

    Westerik, Janine A. M.; Carter, Victoria; Chrystyn, Henry; Burden, Anne; Thompson, Samantha L.; Ryan, Dermot; Gruffydd-Jones, Kevin; Haughney, John; Roche, Nicolas; Lavorini, Federico; Papi, Alberto; Infantino, Antonio; Roman-Rodriguez, Miguel; Bosnic-Anticevich, Sinthia; Lisspers, Karin; Ställberg, Björn; Henrichsen, Svein Høegh; van der Molen, Thys; Hutton, Catherine; Price, David B.

    2016-01-01

    Abstract Objective: Correct inhaler technique is central to effective delivery of asthma therapy. The study aim was to identify factors associated with serious inhaler technique errors and their prevalence among primary care patients with asthma using the Diskus dry powder inhaler (DPI). Methods: This was a historical, multinational, cross-sectional study (2011–2013) using the iHARP database, an international initiative that includes patient- and healthcare provider-reported questionnaires from eight countries. Patients with asthma were observed for serious inhaler errors by trained healthcare providers as predefined by the iHARP steering committee. Multivariable logistic regression, stepwise reduced, was used to identify clinical characteristics and asthma-related outcomes associated with ≥1 serious errors. Results: Of 3681 patients with asthma, 623 (17%) were using a Diskus (mean [SD] age, 51 [14]; 61% women). A total of 341 (55%) patients made ≥1 serious errors. The most common errors were the failure to exhale before inhalation, insufficient breath-hold at the end of inhalation, and inhalation that was not forceful from the start. Factors significantly associated with ≥1 serious errors included asthma-related hospitalization the previous year (odds ratio [OR] 2.07; 95% confidence interval [CI], 1.26–3.40); obesity (OR 1.75; 1.17–2.63); poor asthma control the previous 4 weeks (OR 1.57; 1.04–2.36); female sex (OR 1.51; 1.08–2.10); and no inhaler technique review during the previous year (OR 1.45; 1.04–2.02). Conclusions: Patients with evidence of poor asthma control should be targeted for a review of their inhaler technique even when using a device thought to have a low error rate. PMID:26810934

  17. The analytical representation of viscoelastic material properties using optimization techniques

    NASA Technical Reports Server (NTRS)

    Hill, S. A.

    1993-01-01

    This report presents a technique to model viscoelastic material properties with a function of the form of the Prony series. Generally, the method employed to determine the function constants requires assuming values for the exponential constants of the function and then resolving the remaining constants through linear least-squares techniques. The technique presented here allows all the constants to be analytically determined through optimization techniques. This technique is employed in a computer program named PRONY and makes use of commercially available optimization tool developed by VMA Engineering, Inc. The PRONY program was utilized to compare the technique against previously determined models for solid rocket motor TP-H1148 propellant and V747-75 Viton fluoroelastomer. In both cases, the optimization technique generated functions that modeled the test data with at least an order of magnitude better correlation. This technique has demonstrated the capability to use small or large data sets and to use data sets that have uniformly or nonuniformly spaced data pairs. The reduction of experimental data to accurate mathematical models is a vital part of most scientific and engineering research. This technique of regression through optimization can be applied to other mathematical models that are difficult to fit to experimental data through traditional regression techniques.

  18. Evaluation of a residential Kundalini yoga lifestyle pilot program for addiction in India.

    PubMed

    Khalsa, Sat Bir S; Khalsa, Gurucharan S; Khalsa, Hargopal K; Khalsa, Mukta K

    2008-01-01

    Previously reported substance abuse interventions incorporating meditation and spiritual approaches are believed to provide their benefit through modulation of both psychological and pyschosocial factors. A 90-day residential group pilot treatment program for substance abuse that incorporated a comprehensive array of yoga, meditation, spiritual and mind-body techniques was conducted in Amritsar, India. Subjects showed improvements on a number of psychological self-report questionnaires including the Behavior and Symptom Identification Scale and the Quality of Recovery Index. Application of comprehensive spiritual lifestyle interventions may prove effective in treating substance abuse, particularly in populations receptive to such approaches.

  19. Magnetoacoustic imaging of human liver tumor with magnetic induction

    NASA Astrophysics Data System (ADS)

    Hu, Gang; Cressman, Erik; He, Bin

    2011-01-01

    Magnetoacoustic tomography with magnetic induction (MAT-MI) is an imaging technique under development to achieve imaging of electrical impedance contrast in biological tissues with spatial resolution close to ultrasound imaging. However, previously reported MAT-MI experimental results are obtained either from low salinity gel phantoms, or from normal animal tissue samples. In this study, we report the experimental study on the performance of the MAT-MI imaging method for imaging in vitro human liver tumor tissue. The present promising experimental results suggest the feasibility of MAT-MI to image electrical impedance contrast between the cancerous tissue and its surrounding normal tissues.

  20. Life-threatening hematuria requiring transcatheter embolization following radiofrequency ablation of renal cell carcinoma.

    PubMed

    Roach, H; Whittlestone, T; Callaway, M P

    2006-01-01

    Radiofrequency ablation is increasingly being acknowledged as a valid treatment for renal cell carcinoma in patients in whom definitive curative resection is deemed either undesirable or unsafe. A number of published series have shown the technique to have encouraging results and relatively low complication rates. In this article, we report a case of delayed life-threatening hematuria requiring transcatheter embolization of a bleeding intrarenal artery in a patient who had undergone imaging-guided radiofrequency ablation of a 3 cm renal cell carcinoma. To our knowledge, such a complication has not been reported previously.

  1. A facile single-step synthesis of ternary multicore magneto-plasmonic nanoparticles.

    PubMed

    Benelmekki, Maria; Bohra, Murtaza; Kim, Jeong-Hwan; Diaz, Rosa E; Vernieres, Jerome; Grammatikopoulos, Panagiotis; Sowwan, Mukhles

    2014-04-07

    We report a facile single-step synthesis of ternary hybrid nanoparticles (NPs) composed of multiple dumbbell-like iron-silver (FeAg) cores encapsulated by a silicon (Si) shell using a versatile co-sputter gas-condensation technique. In comparison to previously reported binary magneto-plasmonic NPs, the advantage conferred by a Si shell is to bind the multiple magneto-plasmonic (FeAg) cores together and prevent them from aggregation at the same time. Further, we demonstrate that the size of the NPs and number of cores in each NP can be modulated over a wide range by tuning the experimental parameters.

  2. Lactational mastitis caused by Streptococcus lactarius.

    PubMed

    Tena, Daniel; Fernández, Cristina; López-Garrido, Beatriz; Pérez-Balsalobre, Mercedes; Losa, Cristina; Medina-Pascual, María José; Sáez-Nieto, Juan Antonio

    2016-08-01

    Human infections caused by Streptococcus lactarius have not been previously reported. In the present report, we describe a lactational mastitis caused by this organism. The infection occurred in a 28-year-old breast-feeding female, with a 10-days history of moderate pain on the right breast. The patient was cured after antibiotic treatment with levofloxacin for 21 days. Our case shows that S. lactarius should be considered as a cause of lactational mastitis. The introduction of molecular microbiology techniques can be extremely useful for knowing the implication of streptococci in lactational mastitis. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. High-frequency techniques for RCS prediction of plate geometries

    NASA Technical Reports Server (NTRS)

    Balanis, Constantine A.; Polka, Lesley A.

    1992-01-01

    The principal-plane scattering from perfectly conducting and coated strips and rectangular plates is examined. Previous reports have detailed Geometrical Theory of Diffraction/Uniform Theory of Diffraction (GTD/UTD) solutions for these geometries. The GTD/UTD solution for the perfectly conducting plate yields monostatic radar cross section (RCS) results that are nearly identical to measurements and results obtained using the Moment Method (MM) and the Extended Physical Theory of Diffraction (EPTD). This was demonstrated in previous reports. The previous analysis is extended to bistatic cases. GTD/UTD results for the principal-plane scattering from a perfectly conducting, infinite strip are compared to MM and EPTD data. A comprehensive overview of the advantages and disadvantages of the GTD/UTD and of the EPTD and a detailed analysis of the results from both methods are provided. Several previous reports also presented preliminary discussions and results for a GTD/UTD model of the RCS of a coated, rectangular plate. Several approximations for accounting for the finite coating thickness, plane-wave incidence, and far-field observation were discussed. Here, these approximations are replaced by a revised wedge diffraction coefficient that implicitly accounts for a coating on a perfect conductor, plane-wave incidence, and far-field observation. This coefficient is computationally more efficient than the previous diffraction coefficient because the number of Maliuzhinets functions that must be calculated using numerical integration is reduced by a factor of 2. The derivation and the revised coefficient are presented in detail for the hard polarization case. Computations and experimental data are also included. The soft polarization case is currently under investigation.

  4. Multivariate classification with random forests for gravitational wave searches of black hole binary coalescence

    NASA Astrophysics Data System (ADS)

    Baker, Paul T.; Caudill, Sarah; Hodge, Kari A.; Talukder, Dipongkar; Capano, Collin; Cornish, Neil J.

    2015-03-01

    Searches for gravitational waves produced by coalescing black hole binaries with total masses ≳25 M⊙ use matched filtering with templates of short duration. Non-Gaussian noise bursts in gravitational wave detector data can mimic short signals and limit the sensitivity of these searches. Previous searches have relied on empirically designed statistics incorporating signal-to-noise ratio and signal-based vetoes to separate gravitational wave candidates from noise candidates. We report on sensitivity improvements achieved using a multivariate candidate ranking statistic derived from a supervised machine learning algorithm. We apply the random forest of bagged decision trees technique to two separate searches in the high mass (≳25 M⊙ ) parameter space. For a search which is sensitive to gravitational waves from the inspiral, merger, and ringdown of binary black holes with total mass between 25 M⊙ and 100 M⊙ , we find sensitive volume improvements as high as 70±13%-109±11% when compared to the previously used ranking statistic. For a ringdown-only search which is sensitive to gravitational waves from the resultant perturbed intermediate mass black hole with mass roughly between 10 M⊙ and 600 M⊙ , we find sensitive volume improvements as high as 61±4%-241±12% when compared to the previously used ranking statistic. We also report how sensitivity improvements can differ depending on mass regime, mass ratio, and available data quality information. Finally, we describe the techniques used to tune and train the random forest classifier that can be generalized to its use in other searches for gravitational waves.

  5. Double bubble with the big-bubble technique during deep anterior lamellar keratoplasty.

    PubMed

    Wise, Stephanie; Dubord, Paul; Yeung, Sonia N

    2017-04-28

    To report a case of intraoperative double bubble that formed during big-bubble DALK surgery in a patient with corneal scarring secondary to herpetic stromal keratitis. Case report. A 22 year old woman presented with a large corneal scar, likely secondary to previous herpetic stromal keratitis. She underwent big-bubble DALK surgery for visual rehabilitation. Intraoperatively, a mixed bubble with persistent type 2 bubble postoperatively was noted. The second bubble resorbed with clearance of the graft and good visual outcome after 6 weeks. This case report describes the unusual development of a mixed bubble during big-bubble DALK surgery. This graft cleared with resolution of the second bubble postoperatively without further surgical intervention.

  6. A technique of snaring method for fitting a prosthetic valve into the annulus.

    PubMed

    Nagasaka, Shigeo; Kawata, Tetsuji; Matsuta, Masahiro; Taniguchi, Shigeki

    2005-01-01

    Tourniquetting technique to fit a prosthetic valve (PV) into the annulus in valve replacement surgery has been previously reported. We modified the previously reported method and designed a simpler tying technique. We performed 11 aortic (AVR: including four cases for calcified aortic stenosis (AS) with a small annulus and one cases for infective endocarditis with intramuscular abscess cavity), eight mitral valve replacements (MVR), and one tricuspid valve replacement (TVR: for corrected transposition of the great arteries). A PV was implanted using 2-0 polyester mattress sutures with a pledget. Each of the two tourniquets held a suture at the bottom of the annulus and at the opposite position to fit a PV. The sutures between each snare were tied down from the bottom to the top. In MVR, after seating of a PV with two tourniquets, we could make sure that no native tissue of any preserved mitral apparatus disturbed PV leaflet motion. In calcific AS, a PV had a good fitting into the annulus because of tourniquets applied to unseated part during tying sutures. In AVR for infective endocarditis, mattress sutures supported by a Teflon pledget were placed to close the abscess cavity. After snaring on one of these sutures, we tied down the sutures, ensuring that they did not cut through the friable tissues. In TVR, we found that native leaflets interfered with PV motion after seating down the prosthesis and those leaflets were resected before tying down the sutures. Postoperative transesophageal echocardiography showed no paravalvular leakage in any patients and excellent PV functions.

  7. A Novel Technique for Closed Reduction and Fixation of Paediatric Calcaneal Fracture Dislocation Injuries

    PubMed Central

    Faroug, Radwane; Stirling, Paul; Ali, Farhan

    2013-01-01

    Paediatric calcaneal fractures are rare injuries usually managed conservatively or with open reduction and internal fixation (ORIF). Closed reduction was previously thought to be impossible, and very few cases are reported in the literature. We report a new technique for closed reduction using Ilizarov half-rings. We report successful closed reduction and screwless fixation of an extra-articular calcaneal fracture dislocation in a 7-year-old boy. Reduction was achieved using two Ilizarov half-ring frames arranged perpendicular to each other, enabling simultaneous application of longitudinal and rotational traction. Anatomical reduction was achieved with restored angles of Bohler and Gissane. Two K-wires were the definitive fixation. Bony union with good functional outcome and minimal pain was achieved at eight-weeks follow up. ORIF of calcaneal fractures provides good functional outcome but is associated with high rates of malunion and postoperative pain. Preservation of the unique soft tissue envelope surrounding the calcaneus reduces the risk of infection. Closed reduction prevents distortion of these tissues and may lead to faster healing and mobilisation. Closed reduction and screwless fixation of paediatric calcaneal fractures is an achievable management option. Our technique has preserved the soft tissue envelope surrounding the calcaneus, has avoided retained metalwork related complications, and has resulted in a good functional outcome. PMID:23819090

  8. Accurate Estimation of Solvation Free Energy Using Polynomial Fitting Techniques

    PubMed Central

    Shyu, Conrad; Ytreberg, F. Marty

    2010-01-01

    This report details an approach to improve the accuracy of free energy difference estimates using thermodynamic integration data (slope of the free energy with respect to the switching variable λ) and its application to calculating solvation free energy. The central idea is to utilize polynomial fitting schemes to approximate the thermodynamic integration data to improve the accuracy of the free energy difference estimates. Previously, we introduced the use of polynomial regression technique to fit thermodynamic integration data (Shyu and Ytreberg, J Comput Chem 30: 2297–2304, 2009). In this report we introduce polynomial and spline interpolation techniques. Two systems with analytically solvable relative free energies are used to test the accuracy of the interpolation approach. We also use both interpolation and regression methods to determine a small molecule solvation free energy. Our simulations show that, using such polynomial techniques and non-equidistant λ values, the solvation free energy can be estimated with high accuracy without using soft-core scaling and separate simulations for Lennard-Jones and partial charges. The results from our study suggest these polynomial techniques, especially with use of non-equidistant λ values, improve the accuracy for ΔF estimates without demanding additional simulations. We also provide general guidelines for use of polynomial fitting to estimate free energy. To allow researchers to immediately utilize these methods, free software and documentation is provided via http://www.phys.uidaho.edu/ytreberg/software. PMID:20623657

  9. Figure analysis: A teaching technique to promote visual literacy and active Learning.

    PubMed

    Wiles, Amy M

    2016-07-08

    Learning often improves when active learning techniques are used in place of traditional lectures. For many of these techniques, however, students are expected to apply concepts that they have already grasped. A challenge, therefore, is how to incorporate active learning into the classroom of courses with heavy content, such as molecular-based biology courses. An additional challenge is that visual literacy is often overlooked in undergraduate science education. To address both of these challenges, a technique called figure analysis was developed and implemented in three different levels of undergraduate biology courses. Here, students learn content while gaining practice in interpreting visual information by discussing figures with their peers. Student groups also make connections between new and previously learned concepts on their own while in class. The instructor summarizes the material for the class only after students grapple with it in small groups. Students reported a preference for learning by figure analysis over traditional lecture, and female students in particular reported increased confidence in their analytical abilities. There is not a technology requirement for this technique; therefore, it may be utilized both in classrooms and in nontraditional spaces. Additionally, the amount of preparation required is comparable to that of a traditional lecture. © 2016 by The International Union of Biochemistry and Molecular Biology, 44(4):336-344, 2016. © 2016 The International Union of Biochemistry and Molecular Biology.

  10. Patterning techniques for metal organic frameworks.

    PubMed

    Falcaro, Paolo; Buso, Dario; Hill, Anita J; Doherty, Cara M

    2012-06-26

    The tuneable pore size and architecture, chemical properties and functionalization make metal organic frameworks (MOFs) attractive versatile stimuli-responsive materials. In this context, MOFs hold promise for industrial applications and a fervent research field is currently investigating MOF properties for device fabrication. Although the material properties have a crucial role, the ability to precisely locate the functional material is fundamental for device fabrication. In this progress report, advancements in the control of MOF positioning and precise localization of functional materials within MOF crystals are presented. Advantages and limitations of each reviewed technique are critically investigated, and several important gaps in the technological development for device fabrication are highlighted. Finally, promising patterning techniques are presented which are inspired by previous studies in organic and inorganic crystal patterning for the future of MOF lithography. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Actively stabilized optical fiber interferometry technique for online/in-process surface measurement.

    PubMed

    Wang, Kaiwei; Martin, Haydn; Jiang, Xiangqian

    2008-02-01

    In this paper, we report the recent progress in optical-beam scanning fiber interferometry for potential online nanoscale surface measurement based on the previous research. It attempts to generate a robust and miniature measurement device for future development into a multiprobe array measurement system. In this research, both fiber-optic-interferometry and the wavelength-division-multiplexing techniques have been used, so that the optical probe and the optical interferometer are well spaced and fast surface scanning can be carried out, allowing flexibility for online measurement. In addition, this system provides a self-reference signal to stabilize the optical detection with high common-mode noise suppression by adopting an active phase tracking and stabilization technique. Low-frequency noise was significantly reduced compared with unstabilized result. The measurement of a sample surface shows an attained repeatability of 3.3 nm.

  12. Coaxial lithography

    NASA Astrophysics Data System (ADS)

    Ozel, Tuncay; Bourret, Gilles R.; Mirkin, Chad A.

    2015-05-01

    The optical and electrical properties of heterogeneous nanowires are profoundly related to their composition and nanoscale architecture. However, the intrinsic constraints of conventional synthetic and lithographic techniques have limited the types of multi-compositional nanowire that can be created and studied in the laboratory. Here, we report a high-throughput technique that can be used to prepare coaxial nanowires with sub-10 nm control over the architectural parameters in both axial and radial dimensions. The method, termed coaxial lithography (COAL), relies on templated electrochemical synthesis and can create coaxial nanowires composed of combinations of metals, metal oxides, metal chalcogenides and conjugated polymers. To illustrate the possibilities of the technique, a core/shell semiconductor nanowire with an embedded plasmonic nanoring was synthesized—a structure that cannot be prepared by any previously known method—and its plasmon-excitation-dependent optoelectronic properties were characterized.

  13. A comparative study of two different uncinectomy techniques: swing-door and classical.

    PubMed

    Singhania, Ankit A; Bansal, Chetan; Chauhan, Nirali; Soni, Saurav

    2012-01-01

    The aim of this study was to determine which technique of uncinectomy, classical or swing door technique. Four hundred eighty Cases of sinusitis were selected and operated for Functional Endoscopic Sinus Surgery (FESS). Out of these, in 240 uncinectomies classical uncinectomy was done whereas in another 240 uncinectomies swing door technique was used. Initially patients were medically managed treated according to their symptoms and prior management. Patients who had received previous adequate medical management were evaluated with CT scan of the sinuses. If disease still persists than they were operated for FESS. The authors' experience indicates that Functional endoscopic sinus surgery can be performed under local or general anesthesia, as permitted or tolerated. In this review classical technique was used in 240 uncinectomies. Out of this, ethmoidal complex injury was noted in 4 cases, missed maxillary ostium syndrome (incomplete removal) was reported in 12 patients and orbital fat exposure was encountered in 5 patients. As compared to 240 uncinectomies done with swing door technique, incomplete removal was evident in 2 cases and lacrimal duct injury was reported in 3 cases. 'Evidence that underscores how this 'swing door technique' successfully combines 'the conservation goals of the anterior-to-posterior approach and anatomic virtues of the posterior-to-anterior approach to ethmoidectomy of the total 480 uncinectomies operated. Out of which 240 uncinectomies have been performed using the 'swing-door' technique. The 240 uncinectomies performed using classical technique were used as controls. The incidence of orbital penetration, incomplete removal, ethmoidal complex injury and ostium non-identification was significantly less with the new technique. Three lacrimal injuries occurred with the 'swing-door' technique compared to no injuries with classical technique. The authors recommend swing door technique as it is easy to learn, allows complete removal of the uncinate flush with the lateral nasal wall and allows easy identification of the natural ostium of the maxillary sinus without injuring the ethmoidal complex.

  14. Built-Up Area Feature Extraction: Second Year Technical Progress Report

    DTIC Science & Technology

    1990-02-01

    Contract DACA 72-87-C-001. During this year we have built on previous research, in road network extraction and in the detection and delineation of buildings...methods to perform stereo analysis using loosely coupled techniques where comparison is deferred until each method has performed a complete estimate...or missing information. A course of action may be suggested to the user depending on the error. Although the checks do not guarantee the correctness

  15. Non-destructive evaluation of composite materials using ultrasound

    NASA Technical Reports Server (NTRS)

    Miller, J. G.

    1984-01-01

    Investigation of the nondestructive evaluation of advanced composite-laminates is summarized. Indices derived from the measurement of fundamental acoustic parameters are used in order to quantitatively estimate the local material properties of the laminate. The following sections describe ongoing studies of phase insensitive attenuation measurements, and discuss several phenomena which influences the previously reported technique of polar backscatter. A simple and effective programmable gate circuit designed for use in estimating attenuation from backscatter is described.

  16. Locomotion With Loads: Practical Techniques for Predicting Performance Outcomes

    DTIC Science & Technology

    2015-05-01

    running velocities by 13 and 18% for all-out 80- and 400 - meter runs. More recently, Alcaraz et al. (2008) reported only 3% reductions in brief, all... sprint running speeds to be predicted to within 6.0% in both laboratory and field settings. Respective load-carriage algorithms for walking energy...Objective Two: Sprint Running Speed Previous Scientific Efforts: The scientific literature on the basis of brief, all-out running performance is

  17. Locomotion with Loads: Practical Techniques for Predicting Performance Outcomes

    DTIC Science & Technology

    2014-05-01

    out running velocities by 13 and 18% for all-out 80- and 400 - meter runs. More recently, Alcaraz et al. (2008) reported only 3% reductions in brief...induced decrements in all-out sprint running speeds to be predicted to within 6.0% in both laboratory and field settings. Respective load-carriage...model. Objective Two: Sprint Running Speed Previous Scientific Efforts: The scientific literature on the basis of brief, all-out running

  18. Terahertz bandwidth photonic Hilbert transformers based on synthesized planar Bragg grating fabrication.

    PubMed

    Sima, Chaotan; Gates, J C; Holmes, C; Mennea, P L; Zervas, M N; Smith, P G R

    2013-09-01

    Terahertz bandwidth photonic Hilbert transformers are proposed and experimentally demonstrated. The integrated device is fabricated via a direct UV grating writing technique in a silica-on-silicon platform. The photonic Hilbert transformer operates at bandwidths of up to 2 THz (~16 nm) in the telecom band, a 10-fold greater bandwidth than any previously reported experimental approaches. Achieving this performance requires detailed knowledge of the system transfer function of the direct UV grating writing technique; this allows improved linearity and yields terahertz bandwidth Bragg gratings with improved spectral quality. By incorporating a flat-top reflector and Hilbert grating with a waveguide coupler, an ultrawideband all-optical single-sideband filter is demonstrated.

  19. Liquifying PLDLLA Anchor Fixation in Achilles Reconstruction for Insertional Tendinopathy.

    PubMed

    Boden, Stephanie A; Boden, Allison L; Mignemi, Danielle; Bariteau, Jason T

    2018-04-01

    Insertional Achilles tendinopathy (IAT) is a frequent cause of posterior heel pain and is often associated with Haglund's deformity. Surgical correction for refractory cases of IAT has been well studied; however, the method of tendon fixation to bone in these procedures remains controversial, and to date, no standard technique has been identified for tendon fixation in these surgeries. Often, after Haglund's resection, there is large exposed cancellous surface for Achilles reattachment, which may require unique fixation to optimize outcomes. Previous studies have consistently demonstrated improved patient outcomes after Achilles tendon reconstruction with early rehabilitation with protected weight bearing, evidencing the need for a strong and stable anchoring of the Achilles tendon that allows early weight bearing without tendon morbidity. In this report, we highlight the design, biomechanics, and surgical technique of Achilles tendon reconstruction with Haglund's deformity using a novel technique that utilizes ultrasonic energy to liquefy the suture anchor, allowing it to incorporate into surrounding bone. Biomechanical studies have demonstrated superior strength of the suture anchor utilizing this novel technique as compared with prior techniques. However, future research is needed to ensure that outcomes of this technique are favorable when compared with outcomes using traditional suture anchoring methods. Level V: Operative technique.

  20. Evaluation of gravimetric techniques to estimate the microvascular filtration coefficient

    PubMed Central

    Dongaonkar, R. M.; Laine, G. A.; Stewart, R. H.

    2011-01-01

    Microvascular permeability to water is characterized by the microvascular filtration coefficient (Kf). Conventional gravimetric techniques to estimate Kf rely on data obtained from either transient or steady-state increases in organ weight in response to increases in microvascular pressure. Both techniques result in considerably different estimates and neither account for interstitial fluid storage and lymphatic return. We therefore developed a theoretical framework to evaluate Kf estimation techniques by 1) comparing conventional techniques to a novel technique that includes effects of interstitial fluid storage and lymphatic return, 2) evaluating the ability of conventional techniques to reproduce Kf from simulated gravimetric data generated by a realistic interstitial fluid balance model, 3) analyzing new data collected from rat intestine, and 4) analyzing previously reported data. These approaches revealed that the steady-state gravimetric technique yields estimates that are not directly related to Kf and are in some cases directly proportional to interstitial compliance. However, the transient gravimetric technique yields accurate estimates in some organs, because the typical experimental duration minimizes the effects of interstitial fluid storage and lymphatic return. Furthermore, our analytical framework reveals that the supposed requirement of tying off all draining lymphatic vessels for the transient technique is unnecessary. Finally, our numerical simulations indicate that our comprehensive technique accurately reproduces the value of Kf in all organs, is not confounded by interstitial storage and lymphatic return, and provides corroboration of the estimate from the transient technique. PMID:21346245

  1. Satisfactory patient-based outcomes after surgical treatment for idiopathic clubfoot: includes surgeon's individualized technique.

    PubMed

    Mahan, Susan T; Spencer, Samantha A; Kasser, James R

    2014-09-01

    Treatment of idiopathic clubfoot has shifted towards Ponseti technique, but previously surgical management was standard. Outcomes of surgery have varied, with many authors reporting discouraging results. Our purpose was to evaluate a single surgeon's series of children with idiopathic clubfoot treated with a la carte posteromedial and lateral releases using the Pediatric Outcomes Data Collection Instrument (PODCI) with a minimum of 2-year follow-up. A total of 148 patients with idiopathic clubfoot treated surgically by a single surgeon over 15 years were identified, and mailed PODCI questionnaires. Fifty percent of the patients were located and responded, resulting in 74 complete questionnaires. Median age at surgery was 10 months (range, 5.3 to 84.7 mo), male sex 53/74 (71.6%), bilateral surgery 31/74 (41.9%), and average follow-up of 9.7 years. PODCI responses were compared with previously published normal healthy controls using t test for each separate category. Included in the methods is the individual surgeon's operative technique. In PODCIs where a parent reports for their child or adolescent, there was no difference between our data and the healthy controls in any of the 5 categories. In PODCI where an adolescent self-reports, there was no difference in 4 of 5 categories; significant difference was only found between our data (mean = 95.2; SD = 7.427) and normal controls (mean = 86.3; SD = 12.5) in Happiness Scale (P = 0.0031). In this group of idiopathic clubfoot patients, treated with judicious posteromedial release by a single surgeon, primarily when surgery was treatment of choice for clubfoot, patient-based outcomes are not different from their normal healthy peers through childhood and adolescence. While Ponseti treatment has since become the treatment of choice for clubfoot, surgical treatment, in some hands, has led to satisfactory results. Level III.

  2. Generic Sensor Modeling Using Pulse Method

    NASA Technical Reports Server (NTRS)

    Helder, Dennis L.; Choi, Taeyoung

    2005-01-01

    Recent development of high spatial resolution satellites such as IKONOS, Quickbird and Orbview enable observation of the Earth's surface with sub-meter resolution. Compared to the 30 meter resolution of Landsat 5 TM, the amount of information in the output image was dramatically increased. In this era of high spatial resolution, the estimation of spatial quality of images is gaining attention. Historically, the Modulation Transfer Function (MTF) concept has been used to estimate an imaging system's spatial quality. Sometimes classified by target shapes, various methods were developed in laboratory environment utilizing sinusoidal inputs, periodic bar patterns and narrow slits. On-orbit sensor MTF estimation was performed on 30-meter GSD Landsat4 Thematic Mapper (TM) data from the bridge pulse target as a pulse input . Because of a high resolution sensor s small Ground Sampling Distance (GSD), reasonably sized man-made edge, pulse, and impulse targets can be deployed on a uniform grassy area with accurate control of ground targets using tarps and convex mirrors. All the previous work cited calculated MTF without testing the MTF estimator's performance. In previous report, a numerical generic sensor model had been developed to simulate and improve the performance of on-orbit MTF estimating techniques. Results from the previous sensor modeling report that have been incorporated into standard MTF estimation work include Fermi edge detection and the newly developed 4th order modified Savitzky-Golay (MSG) interpolation technique. Noise sensitivity had been studied by performing simulations on known noise sources and a sensor model. Extensive investigation was done to characterize multi-resolution ground noise. Finally, angle simulation was tested by using synthetic pulse targets with angles from 2 to 15 degrees, several brightness levels, and different noise levels from both ground targets and imaging system. As a continuing research activity using the developed sensor model, this report was dedicated to MTF estimation via pulse input method characterization using the Fermi edge detection and 4th order MSG interpolation method. The relationship between pulse width and MTF value at Nyquist was studied including error detection and correction schemes. Pulse target angle sensitivity was studied by using synthetic targets angled from 2 to 12 degrees. In this report, from the ground and system noise simulation, a minimum SNR value was suggested for a stable MTF value at Nyquist for the pulse method. Target width error detection and adjustment technique based on a smooth transition of MTF profile is presented, which is specifically applicable only to the pulse method with 3 pixel wide targets.

  3. Assessment of BCG vaccination in India

    PubMed Central

    1957-01-01

    A second assessment of the mass BCG-vaccination campaign in India is described in this report. Data were collected to corroborate the findings of the first assessment and to study certain aspects of the problems they posed. Sample retesting of children vaccinated in the mass campaign reveals a higher and less variable allergy than that reported from the preliminary assessment work. The results indicate that a uniform and reasonably high level of allergy has been induced in Indian schoolchildren vaccinated in the campaign period assessed and that deficiencies in the tuberculin test by which the allergy was measured rather than defects of vaccine or vaccination technique were responsible for the disappointing variability initially reported. Testing of unvaccinated village populations in Madras and Mysore confirms previous observations that low-grade, non-specific tuberculin sensitivity is widely prevalent in South India, making it virtually impossible to separate the infected from the uninfected with the tuberculin tests in use today. The development of new techniques for use in areas where the low-grade, non-specific sensitivity is widespread is discussed. PMID:13489464

  4. Intradiscal injection of triamcinolone hexacetonide for acute, subacute, and chronic sciatica. Results at 3 months an open-prospectus study of 30 cases and review of the literature.

    PubMed

    Bertin, P; Rochet, N; Arnaud, M; Treves, R; Desproges Gotteron, R; Charissoux, J L

    1990-09-01

    The authors report an open study of 30 cases of intradiscal injection of triamcinolone hexacetonide in the treatment of sciatica. The patients were monitored at months 1 and 3. The results were judged to be good in 36.6% of the cases, moderate in 36.6% and poor in 26.7% of the cases. Two adverse effects were reported: 1 case of reversible urinary retention and 1 case of deficiency of the dorsiflexor muscles of the foot. The good results reported in previous series were only found in this study when the indications were restricted to certain favourable prognostic factors: duration of sciatica less than 6 months and CAT-scan appearance of discal hernia. This technique has the advantage of being simple, economical and nonallergic. On the basis of the encouraging results of the initial series, this technique should be considered as an interesting therapeutic alternative in sciatica. Larger series and double-blind studies, however, are necessary to confirm the initial results.

  5. Anterior ankle arthrodesis

    PubMed Central

    Slater, Gordon L; Sayres, Stephanie C; O’Malley, Martin J

    2014-01-01

    Ankle arthrodesis is a common procedure that resolves many conditions of the foot and ankle; however, complications following this procedure are often reported and vary depending on the fixation technique. Various techniques have been described in the attempt to achieve ankle arthrodesis and there is much debate as to the efficiency of each one. This study aims to evaluate the efficiency of anterior plating in ankle arthrodesis using customised and Synthes TomoFix plates. We present the outcomes of 28 ankle arthrodeses between 2005 and 2012, specifically examining rate of union, patient-reported outcomes scores, and complications. All 28 patients achieved radiographic union at an average of 36 wk; the majority of patients (92.86%) at or before 16 wk, the exceptions being two patients with Charcot joints who were noted to have bony union at a three year review. Patient-reported outcomes scores significantly increased (P < 0.05). Complications included two delayed unions as previously mentioned, infection, and extended postoperative pain. With multiple points for fixation and coaxial screw entry points, the contoured customised plate offers added compression and provides a rigid fixation for arthrodesis stabilization. PMID:24649408

  6. Multicenter evaluation of quality of life and patient satisfaction after breast reconstruction, a long-term retrospective study.

    PubMed

    Ménez, T; Michot, A; Tamburino, S; Weigert, R; Pinsolle, V

    2018-04-01

    Breast reconstruction techniques are multiple and they should be chosen in order to improve women's satisfaction and well-being, thus obtaining a personalized treatment. This report's major purpose was to study, through the Breast-Q questionnaire, how the functional and aesthetic outcomes, as well as the complications, of the main autologous breast reconstruction techniques, can affect patients quality of life and well-being at long-term. The secondary purpose was to analyse, thus to identify, the independent factors characterizing the different reconstructive techniques, which may affect patients' satisfaction. Women who underwent autologous breast reconstruction through deep inferior epigastric artery perforator or Latissimus dorsi muscle flap from May 2006 to May 2013 were included. The assessment was based on the Breast-Q reconstruction questionnaire. All times of post-mastectomy reconstruction were concerned: immediate, delayed, after previous procedure failure or conversion to another reconstructive technique due to the patient's dissatisfaction. A total of 98 patients were included. Concerning patients satisfaction, the breast-Q score is highest in patients who underwent immediate breast reconstruction, while scores after delayed breast reconstruction, previous surgery failure or conversion to another technique are generally equivalent. Higher scores have been observed in patients who underwent reconstruction through autologous Latissimus dorsi compared to Latissimus dorsi with prosthetic implant reconstruction. The authors identified factors of higher patients' satisfaction, like absence of major complication and advanced patient's age, in order to personalize the surgical planning according to the patient's priorities. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  7. Proposed alternative revision strategy for broken S1 pedicle screw: radiological study, review of the literature, and case reports.

    PubMed

    Elgafy, Hossein; Miller, Jacob D; Benedict, Gregory M; Seal, Ryan J; Liu, Jiayong

    2013-07-01

    There have been many reports outlining differing methods for managing a broken S1 screw. To the authors' best knowledge, the technique used in the present study has not been described previously. It involves insertion of a second pedicle screw without removing the broken screw shaft. Radiological study, literature review, and two case reports of the surgical technique. To report a proposed new surgical technique for management of broken S1 pedicle screws. Computed tomography (CT) scans of 50 patients with a total of 100 S1 pedicles were analyzed. There were 25 male and 25 female patients with an average age of 51 years ranging from 36 to 68 years. The cephalad-caudal length, medial-lateral width, and cross-sectional area of the S1 pedicle were measured and compared with the diameter of a pedicle screw to illustrate the possibility of inserting a second screw in S1 pedicle without removal of the broken screw shaft. Two case reports of the proposed technique are presented. The left and right S1 pedicle cross-sectional area in female measured 456.00 ± 4.00 and 457.00 ± 3.00 mm(2), respectively. The left and right S1 pedicle cross-section area in male measured 638.00 ± 2.00 and 639.00 ± 1.00 mm(2), respectively. There were statistically significant differences when comparing male and female S1 pedicle length, width, and cross-sectional area (p<.05). At 2-year follow-up, the two case reports of the proposed technique showed resolution of low back pain and radicular pain. Plain radiograph and CT scan showed posterolateral fusion mass and hardware in good position with no evidence of screw loosening. The S1 pedicle dimensions measured on CT scan reviewed in the present study showed that it may be anatomically feasible to place a second screw through the S1 pedicle without the removal of the broken screw shaft. This treatment method will reduce the complications associated with other described revision strategies for broken S1 screws. Published by Elsevier Inc.

  8. A Comparative Biomechanical Analysis of 2 Double-Row, Distal Triceps Tendon Repairs

    PubMed Central

    Dorweiler, Matthew A.; Van Dyke, Rufus O.; Siska, Robert C.; Boin, Michael A.; DiPaola, Mathew J.

    2017-01-01

    Background: Triceps tendon ruptures are rare orthopaedic injuries that almost always require surgical repair. This study tests the biomechanical properties of an original anchorless double-row triceps repair against a previously reported knotless double-row repair. Hypothesis: The anchorless double-row triceps repair technique will yield similar biomechanical properties when compared with the knotless double-row repair technique. Study Design: Controlled laboratory study. Methods: Eighteen cadaver arms were randomized into 2 groups. One group received the anchorless repair and the other received the knotless anchor repair. A materials testing system (MTS) machine was used to cycle the repaired arms from 0° to 90° with a 2.5-pound weight for 1500 cycles at 0.25 Hz. Real-time displacement of the tendon was measured during cycling using a probe. Load to failure was performed after completion of cyclic loading. Results: The mean displacement with the anchorless technique was 0.77 mm (SD, 0.25 mm) at 0° (full elbow extension) and 0.76 mm (SD, 0.38 mm) at 90° (elbow flexion). The mean displacement with the anchored technique was 0.83 mm (SD, 0.57 mm) at 0° and 1.01 mm (SD, 0.62 mm) at 90°. There was no statistically significant difference for tendon displacement at 0º (P = .75) or 90º (P = .31). The mean load to failure with the anchorless technique was 618.9 N (SD, 185.6 N), while it was 560.5 N (SD, 154.1 N) with the anchored technique, again with no statistically significant difference (P = .28). Conclusion: Our anchorless double-row triceps repair technique yields comparable biomechanical properties to previously described double-row triceps tendon repair techniques, with the added benefit of avoiding the cost of suture anchors. Clinical Relevance: This anchorless double-row triceps tendon repair can be considered as an acceptable alternative to a knotless anchor repair for triceps tendon ruptures. PMID:28607942

  9. A Comparative Biomechanical Analysis of 2 Double-Row, Distal Triceps Tendon Repairs.

    PubMed

    Dorweiler, Matthew A; Van Dyke, Rufus O; Siska, Robert C; Boin, Michael A; DiPaola, Mathew J

    2017-05-01

    Triceps tendon ruptures are rare orthopaedic injuries that almost always require surgical repair. This study tests the biomechanical properties of an original anchorless double-row triceps repair against a previously reported knotless double-row repair. The anchorless double-row triceps repair technique will yield similar biomechanical properties when compared with the knotless double-row repair technique. Controlled laboratory study. Eighteen cadaver arms were randomized into 2 groups. One group received the anchorless repair and the other received the knotless anchor repair. A materials testing system (MTS) machine was used to cycle the repaired arms from 0° to 90° with a 2.5-pound weight for 1500 cycles at 0.25 Hz. Real-time displacement of the tendon was measured during cycling using a probe. Load to failure was performed after completion of cyclic loading. The mean displacement with the anchorless technique was 0.77 mm (SD, 0.25 mm) at 0° (full elbow extension) and 0.76 mm (SD, 0.38 mm) at 90° (elbow flexion). The mean displacement with the anchored technique was 0.83 mm (SD, 0.57 mm) at 0° and 1.01 mm (SD, 0.62 mm) at 90°. There was no statistically significant difference for tendon displacement at 0º ( P = .75) or 90º ( P = .31). The mean load to failure with the anchorless technique was 618.9 N (SD, 185.6 N), while it was 560.5 N (SD, 154.1 N) with the anchored technique, again with no statistically significant difference ( P = .28). Our anchorless double-row triceps repair technique yields comparable biomechanical properties to previously described double-row triceps tendon repair techniques, with the added benefit of avoiding the cost of suture anchors. This anchorless double-row triceps tendon repair can be considered as an acceptable alternative to a knotless anchor repair for triceps tendon ruptures.

  10. Shock timing measurements and analysis in deuterium-tritium-ice layered capsule implosions on NIF

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robey, H. F.; Celliers, P. M.; Moody, J. D.

    2014-02-15

    Recent advances in shock timing experiments and analysis techniques now enable shock measurements to be performed in cryogenic deuterium-tritium (DT) ice layered capsule implosions on the National Ignition Facility (NIF). Previous measurements of shock timing in inertial confinement fusion implosions [Boehly et al., Phys. Rev. Lett. 106, 195005 (2011); Robey et al., Phys. Rev. Lett. 108, 215004 (2012)] were performed in surrogate targets, where the solid DT ice shell and central DT gas were replaced with a continuous liquid deuterium (D2) fill. These previous experiments pose two surrogacy issues: a material surrogacy due to the difference of species (D2 vs.more » DT) and densities of the materials used and a geometric surrogacy due to presence of an additional interface (ice/gas) previously absent in the liquid-filled targets. This report presents experimental data and a new analysis method for validating the assumptions underlying this surrogate technique. Comparison of the data with simulation shows good agreement for the timing of the first three shocks, but reveals a considerable discrepancy in the timing of the 4th shock in DT ice layered implosions. Electron preheat is examined as a potential cause of the observed discrepancy in the 4th shock timing.« less

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agarwal, Animesh, E-mail: animesh@zedat.fu-berlin.de; Delle Site, Luigi, E-mail: dellesite@fu-berlin.de

    Quantum effects due to the spatial delocalization of light atoms are treated in molecular simulation via the path integral technique. Among several methods, Path Integral (PI) Molecular Dynamics (MD) is nowadays a powerful tool to investigate properties induced by spatial delocalization of atoms; however, computationally this technique is very demanding. The above mentioned limitation implies the restriction of PIMD applications to relatively small systems and short time scales. One of the possible solutions to overcome size and time limitation is to introduce PIMD algorithms into the Adaptive Resolution Simulation Scheme (AdResS). AdResS requires a relatively small region treated at pathmore » integral level and embeds it into a large molecular reservoir consisting of generic spherical coarse grained molecules. It was previously shown that the realization of the idea above, at a simple level, produced reasonable results for toy systems or simple/test systems like liquid parahydrogen. Encouraged by previous results, in this paper, we show the simulation of liquid water at room conditions where AdResS, in its latest and more accurate Grand-Canonical-like version (GC-AdResS), is merged with two of the most relevant PIMD techniques available in the literature. The comparison of our results with those reported in the literature and/or with those obtained from full PIMD simulations shows a highly satisfactory agreement.« less

  12. A spatially adaptive spectral re-ordering technique for lossless coding of hyper-spectral images

    NASA Technical Reports Server (NTRS)

    Memon, Nasir D.; Galatsanos, Nikolas

    1995-01-01

    In this paper, we propose a new approach, applicable to lossless compression of hyper-spectral images, that alleviates some limitations of linear prediction as applied to this problem. According to this approach, an adaptive re-ordering of the spectral components of each pixel is performed prior to prediction and encoding. This re-ordering adaptively exploits, on a pixel-by pixel basis, the presence of inter-band correlations for prediction. Furthermore, the proposed approach takes advantage of spatial correlations, and does not introduce any coding overhead to transmit the order of the spectral bands. This is accomplished by using the assumption that two spatially adjacent pixels are expected to have similar spectral relationships. We thus have a simple technique to exploit spectral and spatial correlations in hyper-spectral data sets, leading to compression performance improvements as compared to our previously reported techniques for lossless compression. We also look at some simple error modeling techniques for further exploiting any structure that remains in the prediction residuals prior to entropy coding.

  13. The Statistical Package for the Social Sciences (SPSS) as an adjunct to pharmacokinetic analysis.

    PubMed

    Mather, L E; Austin, K L

    1983-01-01

    Computer techniques for numerical analysis are well known to pharmacokineticists. Powerful techniques for data file management have been developed by social scientists but have, in general, been ignored by pharmacokineticists because of their apparent lack of ability to interface with pharmacokinetic programs. Extensive use has been made of the Statistical Package for the Social Sciences (SPSS) for its data handling capabilities, but at the same time, techniques have been developed within SPSS to interface with pharmacokinetic programs of the users' choice and to carry out a variety of user-defined pharmacokinetic tasks within SPSS commands, apart from the expected variety of statistical tasks. Because it is based on a ubiquitous package, this methodology has all of the benefits of excellent documentation, interchangeability between different types and sizes of machines and true portability of techniques and data files. An example is given of the total management of a pharmacokinetic study previously reported in the literature by the authors.

  14. A DNA microarray-based methylation-sensitive (MS)-AFLP hybridization method for genetic and epigenetic analyses.

    PubMed

    Yamamoto, F; Yamamoto, M

    2004-07-01

    We previously developed a PCR-based DNA fingerprinting technique named the Methylation Sensitive (MS)-AFLP method, which permits comparative genome-wide scanning of methylation status with a manageable number of fingerprinting experiments. The technique uses the methylation sensitive restriction enzyme NotI in the context of the existing Amplified Fragment Length Polymorphism (AFLP) method. Here we report the successful conversion of this gel electrophoresis-based DNA fingerprinting technique into a DNA microarray hybridization technique (DNA Microarray MS-AFLP). By performing a total of 30 (15 x 2 reciprocal labeling) DNA Microarray MS-AFLP hybridization experiments on genomic DNA from two breast and three prostate cancer cell lines in all pairwise combinations, and Southern hybridization experiments using more than 100 different probes, we have demonstrated that the DNA Microarray MS-AFLP is a reliable method for genetic and epigenetic analyses. No statistically significant differences were observed in the number of differences between the breast-prostate hybridization experiments and the breast-breast or prostate-prostate comparisons.

  15. Port positioning and docking for single-stage totally robotic dissection for rectal cancer surgery with the Si and Xi Da Vinci Surgical System.

    PubMed

    Toh, James Wei Tatt; Kim, Seon-Hahn

    2017-11-04

    We have previously reported our technique of single-docking totally robotic dissection for rectal cancer surgery using the Da Vinci ® Si Surgical System in 2009. However, we have since optimised our port placement for the Si system and have developed a novel configuration of port placement and docking for the Da Vinci ® Xi Surgical System. We have performed over 700 cases using this technique with the Si system and have used our Xi technique since 2016 for totally robotic dissection for rectal cancer. We have kept the configuration of port placements for both the Xi and Si system as similar as possible, with the priorities to avoid arm collisions as well as to provide a workable port configuration of two left-handed instruments and one right-handed instrument. To date, there have had no major complications or arm collisions related to this technique of docking, port positioning and instrument placement.

  16. Composite aortic root replacement using the classic or modified Cabrol coronary artery implantation technique.

    PubMed

    Garlicki, Miroslaw; Roguski, K; Puchniewicz, M; Ehrlich, Marek P

    2006-08-01

    We report in this study our results with composite aortic root replacement (CVR) using the classic or modified Cabrol coronary implantation technique. From October 2001 to March 2005, 25 patients underwent aortic root replacement. In all cases, the indication for surgery was a degenerative aneurysm with a diameter of more than 6 cm. Seven patients had undergone a previous aortic operation on the ascending aorta. Mean age was 53+/-13 years and 22 patients were male. Mean Euroscore was 5.2+/-2.4. Aortic insufficiency was present in all patients. Two patients had Marfan syndrome. The 30-day mortality was 0%. Two patients required profound hypothermic circulatory arrest. Mean aortic cross-clamp time was 91+/-24 minutes and the mean circulatory arrest time was 24+/-15 minutes. No patients developed a pseudoaneurysm after the operation. We conclude that composite aortic root replacement with the classic or modified Cabrol technique results in a low operative mortality. However, it should be only used when a "button" technique is not feasible.

  17. An evaluation of machine processing techniques of ERTS-1 data for user applications. [urban land use and soil association mapping in Indiana

    NASA Technical Reports Server (NTRS)

    Landgrebe, D.

    1974-01-01

    A broad study is described to evaluate a set of machine analysis and processing techniques applied to ERTS-1 data. Based on the analysis results in urban land use analysis and soil association mapping together with previously reported results in general earth surface feature identification and crop species classification, a profile of general applicability of this procedure is beginning to emerge. Put in the hands of a user who knows well the information needed from the data and also is familiar with the region to be analyzed it appears that significantly useful information can be generated by these methods. When supported by preprocessing techniques such as the geometric correction and temporal registration capabilities, final products readily useable by user agencies appear possible. In parallel with application, through further research, there is much potential for further development of these techniques both with regard to providing higher performance and in new situations not yet studied.

  18. A Very Efficient Transfer Function Bounding Technique on Bit Error Rate for Viterbi Decoded, Rate 1/N Convolutional Codes

    NASA Technical Reports Server (NTRS)

    Lee, P. J.

    1984-01-01

    For rate 1/N convolutional codes, a recursive algorithm for finding the transfer function bound on bit error rate (BER) at the output of a Viterbi decoder is described. This technique is very fast and requires very little storage since all the unnecessary operations are eliminated. Using this technique, we find and plot bounds on the BER performance of known codes of rate 1/2 with K 18, rate 1/3 with K 14. When more than one reported code with the same parameter is known, we select the code that minimizes the required signal to noise ratio for a desired bit error rate of 0.000001. This criterion of determining goodness of a code had previously been found to be more useful than the maximum free distance criterion and was used in the code search procedures of very short constraint length codes. This very efficient technique can also be used for searches of longer constraint length codes.

  19. Chromosomal Rainbows detect Oncogenic Rearrangements of Signaling Molecules in Thyroid Tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Brien, Benjamin; Jossart, Gregg H.; Ito, Yuko

    2010-08-19

    Altered signal transduction can be considered a hallmark of many solid tumors. In thyroid cancers the receptor tyrosine kinase (rtk) genes NTRK1 (Online Mendelian Inheritance in Man = OMIM *191315, also known as 'TRKA'), RET ('Rearranged during Transfection protooncogene', OMIM *164761) and MET (OMIM *164860) have been reported as activated, rearranged or overexpressed. In many cases, a combination of cytogenetic and molecular techniques allows elucidation of cellular changes that initiate tumor development and progression. While the mechanisms leading to overexpression of the rtk MET gene remain largely unknown, a variety of chromosomal rearrangements of the RET or NTKR1 gene couldmore » be demonstrated in thyroid cancer. Abnormal expressions in these tumors seem to follow a similar pattern: the rearrangement translocates the 3'-end of the rtk gene including the entire catalytic domain to an expressed gene leading to a chimeric RNA and protein with kinase activity. Our research was prompted by an increasing number of reports describing translocations involving ret and previously unknown translocation partners. We developed a high resolution technique based on fluorescence in situ hybridization (FISH) to allow rapid screening for cytogenetic rearrangements which complements conventional chromosome banding analysis. Our technique applies simultaneous hybridization of numerous probes labeled with different reporter molecules which are distributed along the target chromosome allowing the detection of cytogenetic changes at near megabase-pair (Mbp) resolution. Here, we report our results using a probe set specific for human chromosome 10, which is altered in a significant portion of human thyroid cancers (TC's). While rendering accurate information about the cytogenetic location of rearranged elements, our multi-locus, multi-color analysis was developed primarily to overcome limitations of whole chromosome painting (WCP) and chromosome banding techniques for fine mapping of breakpoints in papillary thyroid cancer (PTC).« less

  20. Fluorescence spectroscopy for diagnosis of squamous intraepithelial lesions of the cervix.

    PubMed

    Mitchell, M F; Cantor, S B; Ramanujam, N; Tortolero-Luna, G; Richards-Kortum, R

    1999-03-01

    To calculate receiver operating characteristic (ROC) curves for fluorescence spectroscopy in order to measure its performance in the diagnosis of squamous intraepithelial lesions (SILs) and to compare these curves with those for other diagnostic methods: colposcopy, cervicography, speculoscopy, Papanicolaou smear screening, and human papillomavirus (HPV) testing. Data from our previous clinical study were used to calculate ROC curves for fluorescence spectroscopy. Curves for other techniques were calculated from other investigators' reports. To identify these, a MEDLINE search for articles published from 1966 to 1996 was carried out, using the search terms "colposcopy," "cervicoscopy," "cervicography," "speculoscopy," "Papanicolaou smear," "HPV testing," "fluorescence spectroscopy," and "polar probe" in conjunction with the terms "diagnosis," "positive predictive value," "negative predictive value," and "receiver operating characteristic curve." We found 270 articles, from which articles were selected if they reported results of studies involving high-disease-prevalence populations, reported findings of studies in which colposcopically directed biopsy was the criterion standard, and included sufficient data for recalculation of the reported sensitivities and specificities. We calculated ROC curves for fluorescence spectroscopy using Bayesian and neural net algorithms. A meta-analytic approach was used to calculate ROC curves for the other techniques. Areas under the curves were calculated. Fluorescence spectroscopy using the neural net algorithm had the highest area under the ROC curve, followed by fluorescence spectroscopy using the Bayesian algorithm, followed by colposcopy, the standard diagnostic technique. Cervicography, Papanicolaou smear screening, and HPV testing performed comparably with each other but not as well as fluorescence spectroscopy and colposcopy. Fluorescence spectroscopy performs better than colposcopy and other techniques in the diagnosis of SILs. Because it also permits real-time diagnosis and has the potential of being used by inexperienced health care personnel, this technology holds bright promise.

  1. Determinations of rare earth element abundance and U-Pb age of zircons using multispot laser ablation-inductively coupled plasma mass spectrometry.

    PubMed

    Yokoyama, Takaomi D; Suzuki, Toshihiro; Kon, Yoshiaki; Hirata, Takafumi

    2011-12-01

    We have developed a new calibration technique for multielement determination and U-Pb dating of zircon samples using laser ablation-inductively coupled plasma mass spectrometry (ICPMS) coupled with galvanometric optics. With the galvanometric optics, laser ablation of two or more sample materials could be achieved in very short time intervals (~10 ms). The resulting sample aerosols released from different ablation pits or different solid samples were mixed and homogenized within the sample cell and then transported into the ICP ion source. Multiple spot laser ablation enables spiking of analytes or internal standard elements directly into the solid samples, and therefore the standard addition calibration method can be applied for the determination of trace elements in solid samples. In this study, we have measured the rare earth element (REE) abundances of two zircon samples (Nancy 91500 and Prešovice) based on the standard addition technique, using a direct spiking of analytes through a multispot laser ablation of the glass standard material (NIST SRM612). The resulting REE abundance data show good agreement with previously reported values within analytical uncertainties achieved in this study (10% for most elements). Our experiments demonstrated that nonspectroscopic interferences on 14 REEs could be significantly reduced by the standard addition technique employed here. Another advantage of galvanometric devices is the accumulation of sample aerosol released from multiple spots. In this study we have measured the U-Pb age of a zircon sample (LMR) using an accumulation of sample aerosols released from 10 separate ablation pits of low diameters (~8 μm). The resulting (238)U-(206)Pb age data for the LMR zircons was 369 ± 64 Ma, which is in good agreement with previously reported age data (367.6 ± 1.5 Ma). (1) The data obtained here clearly demonstrate that the multiple spot laser ablation-ICPMS technique can become a powerful approach for elemental and isotopic ratio measurements in solid materials.

  2. Infrared spectroscopy as a screening technique for colitis

    NASA Astrophysics Data System (ADS)

    Titus, Jitto; Ghimire, Hemendra; Viennois, Emilie; Merlin, Didier; Perera, A. G. Unil

    2017-05-01

    There remains a great need for diagnosis of inflammatory bowel disease (IBD), for which the current technique, colonoscopy, is not cost-effective and presents a non-negligible risk for complications. Attenuated Total Reflectance Fourier Transform Infrared (ATR-FTIR) spectroscopy is a new screening technique to evaluate colitis. Comparing infrared spectra of sera to study the differences between them can prove challenging due to the complexity of its biological constituents giving rise to a plethora of vibrational modes. Overcoming these inherent infrared spectral analysis difficulties involving highly overlapping absorbance peaks and the analysis of the data by curve fitting to improve the resolution is discussed. The proposed technique uses colitic and normal wild type mice dried serum to obtain ATR/FTIR spectra to effectively differentiate colitic mice from normal mice. Using this method, Amide I group frequency (specifically, alpha helix to beta sheet ratio of the protein secondary structure) was identified as disease associated spectral signature in addition to the previously reported glucose and mannose signatures in sera of chronic and acute mice models of colitis. Hence, this technique will be able to identify changes in the sera due to various diseases.

  3. Apico-Aortic Conduit for severe aortic stenosis: Technique, applications, and systematic review

    PubMed Central

    Elmistekawy, Elsayed; Lapierre, Harry; Mesana, Thierry; Ruel, Marc

    2010-01-01

    Patients referred for aortic valve replacement are often elderly and may have increased surgical risk associated with ascending aortic calcification, left ventricular dysfunction, presence of coronary artery disease, previous surgery, and/or presence of several co-morbidities. Some of these patients may not be considered candidates for conventional surgery because of their high risk profile. While transcatheter aortic valve replacement constitutes a widely accepted alternative, some patients may not be eligible for this modality due to anatomic factors. Apico-Aortic Conduit (AAC) insertion (aortic valve bypass surgery) constitutes a possible option in those patients. Apico-Aortic Conduit is not a new technique, as it has been used for decades in both pediatric and adult populations. However, there is a resurging interest in this technique due to the expanding scope of elderly patients being considered for the treatment of aortic stenosis. Herein, we describe our surgical technique and provide a systematic review of recent publications on AAC insertion, reporting that there is continued use and several modifications of this technique, such as performing it through a small thoracotomy without the use of the cardiopulmonary bypass. PMID:23960619

  4. Simplified multiple headspace extraction gas chromatographic technique for determination of monomer solubility in water.

    PubMed

    Chai, X S; Schork, F J; DeCinque, Anthony

    2005-04-08

    This paper reports an improved headspace gas chromatographic (GC) technique for determination of monomer solubilities in water. The method is based on a multiple headspace extraction GC technique developed previously [X.S. Chai, Q.X. Hou, F.J. Schork, J. Appl. Polym. Sci., in press], but with the major modification in the method calibration technique. As a result, only a few iterations of headspace extraction and GC measurement are required, which avoids the "exhaustive" headspace extraction, and thus the experimental time for each analysis. For highly insoluble monomers, effort must be made to minimize adsorption in the headspace sampling channel, transportation conduit and capillary column by using higher operating temperature and a short capillary column in the headspace sampler and GC system. For highly water soluble monomers, a new calibration method is proposed. The combinations of these technique modifications results in a method that is simple, rapid and automated. While the current focus of the authors is on the determination of monomer solubility in aqueous solutions, the method should be applicable to determination of solubility of any organic in water.

  5. [Unilateral laparoscopic cryptorchidectomy in a llama].

    PubMed

    Zulauf, M; Bergadano, A; Steiner, A

    2002-05-01

    Cryptorchism is an inherited congenital abnormality characterized by the failure of one or both testes to descend into the scrotum. Diagnosis can be difficult if the retained testicular tissue cannot be localized during clinical examination and the history of the animal is unknown, or if the animal shows persistent male behaviour despite the history of successful previous castration. The present case report describes the history of a cryptorchid Lama and the techniques of general anesthesia and laparoscopic cryptorchidectomy advocated.

  6. Redo thoracic endovascular aortic repair due to endoleak with celiac artery snorkeling.

    PubMed

    Planer, David; Bliagos, Dimitrios; Gray, William A

    2011-10-01

    Reintervention due to endoleak of aortic endograft repair is often challenging. Herein, we report endovascular endoleak repair in a patient with previous thoracic and abdominal endovascular grafts with extensive coverage of the aorta. The present technique included snorkeling of the celiac trunk to preserve antegrade flow in the celiac artery and to maintain future options for reintervention. Copyright © 2011 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  7. A note on the effects of viscosity on the stability of a trailing-line vortex

    NASA Technical Reports Server (NTRS)

    Duck, Peter W.; Khorrami, Mehdi R.

    1992-01-01

    The linear stability of the Batchelor (1964) vortex is examined with emphasis on new viscous modes recently found numerically by Khorrami (1991). Unlike the previously reported inviscid modes of instability, these modes are destabilized by viscosity and exhibit small growth rates at large Reynolds numbers. The analysis presented here uses a combination of asymptotic and numerical techniques. The results confirm the existence of the additional modes of instability due to viscosity.

  8. Locomotion with Loads: Practical Techniques for Predicting Performance Outcomes

    DTIC Science & Technology

    2013-05-01

    Lotens (1992) who reported that a load equal to 21% of body weight reduced all-out running velocities by 13 and 18% for all-out 80- and 400 - meter runs...hypothesize second that the speed-load carriage algorithms will allow load- induced decrements in all-out sprint running speeds to be predicted to within...1968; Santee et al., 2001) may then be explored in the context of the model. Objective Two: Sprint Running Speed Previous Scientific Efforts

  9. No Evidence of Isomerism for the First Excited State of {sup 93}Rb

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miernik, K., E-mail: kmiernik@fuw.edu.pl; Gross, C.J.; Grzywacz, R.

    2014-06-15

    The 253.3–keV excited state located in {sup 93}Rb was studied at the Holifield Radioactive Ion Beam Facility in Oak Ridge. This state, described as isomeric in databases, was populated in the decay of {sup 93}Kr produced by proton–induced fission of {sup 238}U and isolated using the isotope separation on–line technique. We report that the 253.3–keV level does not reveal isomerism and the upper limit of the half-life from our measurement is 4 ns. Our findings are supported by previously reported results that were not taken into account in the latest nuclear databases.

  10. Application of radar for automotive collision avoidance. Volume 2: Development plan and progress reports

    NASA Technical Reports Server (NTRS)

    Lichtenberg, Christopher L. (Editor)

    1987-01-01

    The purpose of this project was research and development of an automobile collision avoidance radar system. Items within the scope of the one-year effort were to: (1) review previous authors' work in this field; (2) select a suitable radar approach; (3) develop a system design; (4) perform basic analyses and observations pertinent to radar design, performance, and effects; (5) fabricate and collect radar data from a data collection radar; (6) analyze and derive conclusions from the radar data; and (7) make recommendations about the likelihood of success of the investigated radar techniques. The final technical report presenting all conclusions is contained in Volume 1.

  11. Primary adenosine monophosphate (AMP) deaminase deficiency in a hypotonic infant.

    PubMed

    Castro-Gago, Manuel; Gómez-Lado, Carmen; Pérez-Gay, Laura; Eirís-Puñal, Jesús; Martínez, Elena Pintos; García-Consuegra, Inés; Martín, Miguel Angel

    2011-06-01

    The spectrum of the adenosine monophosphate (AMP) deaminase deficiency ranges from asymptomatic carriers to patients who manifest exercise-induced muscle pain, occasionally rhabdomyolysis, and idiopathic hyperCKemia. However, previous to the introduction of molecular techniques, rare cases with congenital weakness and hypotonia have also been reported. We report a 6-month-old girl with the association of congenital muscle weakness and hypotonia, muscle deficiency of adenosine monophosphate deaminase, and the homozygous C to T mutation at nucleotide 34 of the adenosine monophosphate deaminase-1 gene. This observation indicates the possible existence of a primary adenosine monophosphate deaminase deficiency manifested by congenital muscle weakness and hypotonia.

  12. Adsorption bed models used in simulation of atmospheric control systems

    NASA Technical Reports Server (NTRS)

    Davis, S. H.

    1978-01-01

    Two separate techniques were used to obtain important basic data for the adsorption of seven liquid and eight gaseous trace contaminants. A columetric system used in previous HSC studies was modified to determine the HSC capacity of all the contaminants. A second study of six of the liquids was performed in a gas chromatorgraph. The results of these two studies are reported in two parts. First, a brief summary of the chromatographic results are given. Second, a thesis is given which reports in some detail the results of the volumetric studies. Comparison of the data that are common to both studies are also included.

  13. Treatment of rhinophyma with the Versajet™ Hydrosurgery System and autologous cell suspension (ReCELL®): A case report.

    PubMed

    K, Yıldız; B R, Kayan; T, Dulgeroglu; E, Guneren

    2018-04-01

    This is a case report of a 63-year-old male patient who presented with rhinophyma of 17 years duration. Several medical treatments were applied previously, with no response or poor improvement. We present our experience by combining the Versajet™ Hydrosurgery System and ReCELL ® in a heavy smoker patient, which led to a good aesthetic outcome. With the combined technique, we did not encounter any difficulties either within the operation or in the follow-up period. We obtained less complications and faster wound healing, which in return led to higher patient satisfaction.

  14. Laparoscopic completion cholecystectomy and common bile duct exploration for retained gallbladder after single-incision cholecystectomy.

    PubMed

    Kroh, Matthew; Chalikonda, Sricharan; Chand, Bipan; Walsh, R Matthew

    2013-01-01

    Recent enthusiasm in the surgical community for less invasive surgical approaches has resulted in widespread application of single-incision techniques. This has been most commonly applied in laparoscopic cholecystectomy in general surgery. Cosmesis appears to be improved, but other advantages remain to be seen. Feasibility has been demonstrated, but there is little description in the current literature regarding complications. We report the case of a patient who previously underwent single-incision laparoscopic cholecystectomy for symptomatic gallstone disease. After a brief symptom-free interval, she developed acute pancreatitis. At evaluation, imaging results of ultrasonography and magnetic resonance cholangiopancreatography demonstrated a retained gallbladder with cholelithiasis. The patient was subsequently referred to our hospital, where she underwent further evaluation and surgical intervention. Our patient underwent 4-port laparoscopic remnant cholecystectomy with transcystic common bile duct exploration. Operative exploration demonstrated a large remnant gallbladder and a partially obstructed cystic duct with many stones. Transcystic exploration with balloon extraction resulted in duct clearance. The procedure took 75 minutes, with minimal blood loss. The patient's postoperative course was uneventful. Final pathology results demonstrated a remnant gallbladder with cholelithiasis and cholecystitis. This report is the first in the literature to describe successful laparoscopic remnant cholecystectomy and transcystic common bile duct exploration after previous single-port cholecystectomy. Although inadvertent partial cholecystectomy is not unique to this technique, single-port laparoscopic procedures may result in different and significant complications.

  15. Wavelet theory applied to the study of spectra of trans-Neptunian objects

    NASA Astrophysics Data System (ADS)

    Souza-Feliciano, A. C.; Alvarez-Candal, A.; Jiménez-Teja, Y.

    2018-06-01

    Context. Reflection spectroscopy in the near-infrared (NIR) is used to investigate the surface composition of trans-Neptunian objects (TNOs). In general, these spectra are difficult to interpret due to the low apparent brightness of the TNOs, causing low signal-to-noise ratio even in spectra obtained with the largest telescopes available on Earth, making it necessary to use filtering techniques to analyze and interpret them. Aims: The purpose of this paper is to present a methodology to analyze the spectra of TNOs. Specifically, our aim was to filter these spectra in the best possible way: maximizing noise removal, while minimizing the loss of signal. Methods: We used wavelets to filter the spectra. Wavelets are a mathematical tool that decompose the signal into its constituent parts, allowing us to analyze the data in different areas of frequencies with the resolution of each component tied to its scale. To check the reliability of our method, we compared the filtered spectra with the spectra of water and methanol ices to identify some common structures between them. Results: Of the 50 TNOs in our sample, we identify traces of water ices and methanol in the spectra of several of them, some with previous reports, while for other objects there were no previous reports. Conclusions: We conclude that the wavelet technique is successful in filtering spectra of TNOs.

  16. Refinement of pressure calibration for multi-anvil press experiments

    NASA Astrophysics Data System (ADS)

    Ono, S.

    2016-12-01

    Accurate characterization of the pressure and temperature environment in high-pressure apparatuses is of essential importance when we apply laboratory data to the study of the Earth's interior. Recently, the synchrotron X-ray source can be used for the high-pressure experiments, and the in situ pressure calibration has been a common technique. However, this technique cannot be used in the laboratory-based experiments. Even now, the conventional pressure calibration is of great interest to understand the Earth's interior. Several high-pressure phase transitions used as the pressure calibrants in the laboratory-based multi-anvil experiments have been investigated. Precise determinations of phase boundaries of CaGeO3 [1], Fe2SiO4 [2], SiO2, and Zr [3] were performed by the multi-anvil press or the diamond anvil cell apparatuses combined with the synchrotron X-ray diffraction technique. The transition pressures in CaGeO3 (garnet-perovskite), Fe2SiO4 (alfa-gamma), and SiO2 (coesite-stishovite) were in general agreement with those reported by previous studies. However, significant discrepancies for the slopes, dP/dT, of these transitions between our and previous studies were confirmed. In the case of Zr study [3], our experimental results elucidate the inconsistency in the transition pressure between omega and beta phase in Zr observed in previous studies. [1] Ono et al. (2011) Phys. Chem. Minerals, 38, 735-740.[2] Ono et al. (2013) Phys. Chem. Minerals, 40, 811-816.[3] Ono & Kikegawa (2015) J. Solid State Chem., 225, 110-113.

  17. The speciation of aqueous zinc(II) bromide solutions to 500 °C and 900 MPa determined using Raman spectroscopy

    USGS Publications Warehouse

    Mibe, Kenji; Chou, I-Ming; Anderson, Alan J.; Mayanovic, Robert A.; Bassett, William A.

    2009-01-01

    A Raman spectral study was carried out on 3 solutions of varying concentration and bromide/zinc ratios. Spectra were collected at 11 different temperature-pressure conditions ranging from ambient to 500????C-0.9??GPa. Raman band assignments for zinc(II) bromide species reported in previous studies were used to determine the relative concentrations of ZnBr42-, ZnBr3-, ZnBr2, and ZnBr+ species at various temperatures and pressures. Our results are in close agreement with X-ray absorption spectroscopic (XAS) data, and confirm that the tetrabromo zinc(II) complex, ZnBr42-, is the predominant species up to 500????C in solutions having high Zn concentrations (1??m) and high bromide/zinc molar ratios ([Br]/[Zn] = 8). In agreement with previous solubility and Raman spectroscopic experiments, our measurements indicate that species with a lower number of halide ligands and charge are favored with increasing temperature in dilute solutions, and solutions with low bromide/zinc ratios ([Br]/[Zn] < 2.5). The Raman technique provides an independent experimental means of evaluating the quality of XAS analyses of data obtained from high temperature disordered systems. The combination of these two techniques provides complementary data on speciation and the structure of zinc(II) bromide complexes. The preponderance of the ZnBr42- species in highly saline brines at high temperature is consistent with the predominance of ZnCl42- in chloride-rich brines reported in previous XAS studies. Knowledge of Zn complexing in metal-rich highly saline brines is important for numerical models of ore deposition in high temperature systems such as skarns and porphyry-type deposits. ?? 2008 Elsevier B.V.

  18. Factors influencing the utilization of empirically supported treatments for eating disorders.

    PubMed

    Simmons, Angela M; Milnes, Suzanne M; Anderson, Drew A

    2008-01-01

    This study expands upon previous research investigating the use of empirically supported treatments (ESTs) for eating disorders by surveying a large sample of clinicians who specialize in treating eating disorders. Surveys developed for this study were sent to 698 members of a large, professional, eating disorder organization who were listed as treatment providers on the organization's website. Despite clinicians reporting frequently using CBT techniques, most identified something other than CBT or IPT as their primary approach to treatment. In contrast with previous research, the majority had received prior training in the use of manual-based treatments. However, consistent with previous investigations, most denied regular use of such treatments. Although manual-based CBT and IPT are referred to as "treatments of choice," professional clinicians in the field are not consistently using them. Responses suggest several barriers to the utilization of ESTs in practice.

  19. Evaluation of culture techniques and bacterial cultures from uroliths.

    PubMed

    Perry, Leigh A; Kass, Philip H; Johnson, Dee L; Ruby, Annette L; Shiraki, Ryoji; Westropp, Jodi L

    2013-03-01

    The association between urolithiasis and growth of bacteria in the urine or urolith has not been recently evaluated in the past 15 years, and the effects of antimicrobial administration on urolith cultures have not been reported. As well, laboratory techniques for urolith cultures have not been critically evaluated. The objectives of the current study were to 1) report bacterial isolates from uroliths and their association with signalment, urolith composition, antimicrobial use, and urine cultures and 2) evaluate laboratory techniques for urolith cultures. For the first objective, a retrospective search of bacterial isolates cultured from uroliths submitted to the laboratory as well as the signalment, urine culture results, and antimicrobial use were recorded. For the second objective, 50 urolith pairs were cultured by washing each urolith either 1or 4 times and culturing the core. Five hundred twenty canine and 168 feline uroliths were reviewed. Struvite-containing uroliths had an increased prevalence of a positive culture compared to nonstruvite-containing uroliths (P < 0.0001, odds ratio [OR] = 5.4), as did uroliths from female dogs (P < 0.0001, OR = 2.9). No significant difference between culture results and previous antimicrobial administration was found (P = 0.41). Eighteen percent of cases with negative urine cultures had positive urolith cultures. There was no significant difference in core culture results whether the urolith was washed 1 or 4 times (P = 0.07). Urolith culture outcome was not always influenced by previous antimicrobial administration, and bacterial culture of a urolith may not yield the same results as those obtained from the urine. The modified protocol, which requires less time and expense for urolith cultures, may be an acceptable alternative.

  20. Comparative Genomic Hybridization–Array Analysis Enhances the Detection of Aneuploidies and Submicroscopic Imbalances in Spontaneous Miscarriages

    PubMed Central

    Schaeffer, Anthony J. ; Chung, June ; Heretis, Konstantina ; Wong, Andrew ; Ledbetter, David H. ; Lese Martin, Christa 

    2004-01-01

    Miscarriage is a condition that affects 10%–15% of all clinically recognized pregnancies, most of which occur in the first trimester. Approximately 50% of first-trimester miscarriages result from fetal chromosome abnormalities. Currently, G-banded chromosome analysis is used to determine if large-scale genetic imbalances are the cause of these pregnancy losses. This technique relies on the culture of cells derived from the fetus, a technique that has many limitations, including a high rate of culture failure, maternal overgrowth of fetal cells, and poor chromosome morphology. Comparative genomic hybridization (CGH)–array analysis is a powerful new molecular cytogenetic technique that allows genomewide analysis of DNA copy number. By hybridizing patient DNA and normal reference DNA to arrays of genomic clones, unbalanced gains or losses of genetic material across the genome can be detected. In this study, 41 product-of-conception (POC) samples, which were previously analyzed by G-banding, were tested using CGH arrays to determine not only if the array could identify all reported abnormalities, but also whether any previously undetected genomic imbalances would be discovered. The array methodology detected all abnormalities as reported by G-banding analysis and revealed new abnormalities in 4/41 (9.8%) cases. Of those, one trisomy 21 POC was also mosaic for trisomy 20, one had a duplication of the 10q telomere region, one had an interstitial deletion of chromosome 9p, and the fourth had an interstitial duplication of the Prader-Willi/Angelman syndrome region on chromosome 15q, which, if maternally inherited, has been implicated in autism. This retrospective study demonstrates that the DNA-based CGH-array technology overcomes many of the limitations of routine cytogenetic analysis of POC samples while enhancing the detection of fetal chromosome aberrations. PMID:15127362

  1. Partitioning of fluorotelomer alcohols to octanol and different sources of dissolved organic carbon.

    PubMed

    Carmosini, Nadia; Lee, Linda S

    2008-09-01

    Interest in the environmental fate of fluorotelomer alcohols (FTOHs) has spurred efforts to understand their equilibrium partitioning behavior. Experimentally determined partition coefficients for FTOHs between soil/water and air/water have been reported, but direct measurements of partition coefficients for dissolved organic carbon (DOC)/water (K(doc)) and octanol/ water(K(ow)) have been lacking. Here we measured the partitioning of 8:2 and 6:2 FTOH between one or more types of DOC and water using enhanced solubility or dialysis bag techniques, and also quantified K(ow) values for 4:2 to 8:2 FTOH using a batch equilibration method. The range in measured log K(doc) values for 8:2 FTOH using the enhanced solubility technique with DOC derived from two soils, two biosolids, and three reference humic acids is 2.00-3.97 with the lowest values obtained for the biosolids and an average across all other DOC sources (biosolid DOC excluded) of 3.54 +/- 0.29. For 6:2 FTOH and Aldrich humic acid, a log K(doc) value of 1.96 +/- 0.45 was measured using the dialysis technique. These average values are approximately 1 to 2 log units lower than previously indirectly estimated K(doc) values. Overall, the affinity for DOC tends to be slightly lower than that for particulate soil organic carbon. Measured log K(ow) values for 4:2 (3.30 +/- 0.04), 6:2 (4.54 +/- 0.01), and 8:2 FTOH (5.58 +/- 0.06) were in good agreement with previously reported estimates. Using relationships between experimentally measured partition coefficients and C-atom chain length, we estimated K(doc) and K(ow) values for shorter and longer chain FTOHs, respectively, that we were unable to measure experimentally.

  2. Development efforts to improve curved-channel microchannel plates

    NASA Technical Reports Server (NTRS)

    Corbett, M. B.; Feller, W. B.; Laprade, B. N.; Cochran, R.; Bybee, R.; Danks, A.; Joseph, C.

    1993-01-01

    Curved-channel microchannel plate (C-plate) improvements resulting from an ongoing NASA STIS microchannel plate (MCP) development program are described. Performance limitations of previous C-plates led to a development program in support of the STIS MAMA UV photon counter, a second generation instrument on the Hubble Space Telescope. C-plate gain, quantum detection efficiency, dark noise, and imaging distortion, which are influenced by channel curvature non-uniformities, have all been improved through use of a new centrifuge fabrication technique. This technique will be described, along with efforts to improve older, more conventional shearing methods. Process optimization methods used to attain targeted C-plate performance goals will be briefly characterized. Newly developed diagnostic measurement techniques to study image distortion, gain uniformity, input bias angle, channel curvature, and ion feedback, will be described. Performance characteristics and initial test results of the improved C-plates will be reported. Future work and applications will also be discussed.

  3. Molecular ecology of hydrothermal vent microbial communities.

    PubMed

    Jeanthon, C

    2000-02-01

    The study of the structure and diversity of hydrothermal vent microbial communities has long been restricted to the morphological description of microorganisms and the use of enrichment culture-based techniques. Until recently the identification of the culturable fraction required the isolation of pure cultures followed by testing for multiple physiological and biochemical traits. However, peculiar inhabitants of the hydrothermal ecosystem such as the invertebrate endosymbionts and the dense microbial mat filaments have eluded laboratory cultivation. Substantial progress has been achieved in recent years in techniques for the identification of microorganisms in natural environments. Application of molecular approaches has revealed the existence of unique and previously unrecognized microorganisms. These have provided fresh insight into the ecology, diversity and evolution of mesophilic and thermophilic microbial communities from the deep-sea hydrothermal ecosystem. This review reports the main discoveries made through the introduction of these powerful techniques in the study of deep-sea hydrothermal vent microbiology.

  4. Classified one-step high-radix signed-digit arithmetic units

    NASA Astrophysics Data System (ADS)

    Cherri, Abdallah K.

    1998-08-01

    High-radix number systems enable higher information storage density, less complexity, fewer system components, and fewer cascaded gates and operations. A simple one-step fully parallel high-radix signed-digit arithmetic is proposed for parallel optical computing based on new joint spatial encodings. This reduces hardware requirements and improves throughput by reducing the space-bandwidth produce needed. The high-radix signed-digit arithmetic operations are based on classifying the neighboring input digit pairs into various groups to reduce the computation rules. A new joint spatial encoding technique is developed to present both the operands and the computation rules. This technique increases the spatial bandwidth product of the spatial light modulators of the system. An optical implementation of the proposed high-radix signed-digit arithmetic operations is also presented. It is shown that our one-step trinary signed-digit and quaternary signed-digit arithmetic units are much simpler and better than all previously reported high-radix signed-digit techniques.

  5. Adaption from LWIR to visible wavebands of methods to describe the population of GEO belt debris

    NASA Astrophysics Data System (ADS)

    Meng, Kevin; Murray-Krezan, Jeremy; Seitzer, Patrick

    2018-05-01

    Prior efforts to characterize the number of GEO belt debris objects by statistically analyzing the distribution of debris as a function of size have relied on techniques unique to infrared measurements of the debris. Specifically the infrared measurement techniques permitted inference of the characteristic size of the debris. This report describes a method to adapt the previous techniques and measurements to visible wavebands. Results will be presented using data from a NASA optical, visible band survey of objects near the geosynchronous orbit, GEO belt. This survey used the University of Michigan's 0.6-m Curtis-Schmidt telescope, Michigan Orbital DEbris Survey Telescope (MODEST), located at Cerro Tololo Inter-American Observatory in Chile. The system is equipped with a scanning CCD with a field of view of 1.6°×1.6°, and can detect objects smaller than 20 cm diameter at GEO.

  6. On the reliability of the occlusion technique as a tool for the assessment of the HMI of in-vehicle information and communication systems.

    PubMed

    Gelau, Christhard; Henning, Matthias J; Krems, Josef F

    2009-03-01

    In recent years considerable efforts have been spent on the development of the occlusion technique as a procedure for the assessment of the human-machine interface of in-vehicle information and communication systems (IVIS) designed to be used by the driver while driving. The importance and significance of the findings resulting from the application of this procedure depends essentially on its reliability. Because there is a lack of evidence as to whether this basic criterion of measurement is met with this procedure, and because questionable reliability can lead to doubts about their validity, our project strove to clarify this issue. This paper reports on a statistical reanalysis of data obtained from previous experiments. To summarise, the characteristic values found for internal consistency were almost all in the range of .90 for the occlusion technique, which can be considered satisfactory.

  7. Fabrication of Fe1.1Se0.5Te0.5 bulk by a high energy ball milling technique

    NASA Astrophysics Data System (ADS)

    Liu, Jixing; Li, Chengshan; Zhang, Shengnan; Feng, Jianqing; Zhang, Pingxiang; Zhou, Lian

    2017-11-01

    Fe1.1Se0.5Te0.5 superconducting bulks were successfully synthesized by a high energy ball milling (HEBM) aided sintering technique. Two advantages of this new technique have been revealed compared with traditional solid state sintering method. One is greatly increased the density of sintered bulks. It is because the precursor powders with β-Fe(Se, Te) and δ-Fe(Se, Te) were obtained directly by the HEBM process and without formation of liquid Se (and Te), which could avoid the huge volume expansion. The other is the obvious decrease of sintering temperature and dwell time due to the effective shortened length of diffusion paths. The superconducting critical temperature Tc of 14.2 K in our sample is comparable with those in previous reports, and further optimization of chemical composition is on the way.

  8. Snow and Ice Mask for the MODIS Aerosol Products

    NASA Technical Reports Server (NTRS)

    Li, Rong-Rong; Remer, Lorraine; Kaufman, Yoram J.; Mattoo, Shana; Gao, Bo-Cai; Vermote, Eric

    2005-01-01

    The atmospheric products have been derived operationally from multichannel imaging data collected with the Moderate Resolution Imaging SpectroRadiometers (MODIS) on board the NASA Terra and Aqua spacecrafts. Preliminary validations of the products were previously reported. Through analysis of more extensive time-series of MODIS aerosol products (Collection 4), we have found that the aerosol products over land areas are slightly contaminated by snow and ice during the springtime snow-melting season. We have developed an empirical technique using MODIS near-IR channels centered near 0.86 and 1.24 pm and a thermal emission channel near 11 pm to mask out these snow-contaminated pixels over land. Improved aerosol retrievals over land have been obtained. Sample results from application of the technique to MODIS data acquired over North America, northern Europe, and northeastern Asia are presented. The technique has been implemented into the MODIS Collection 5 operational algorithm for retrieving aerosols over land from MODIS data.

  9. Solitaire salvage: a stent retriever-assisted catheter reduction technical report.

    PubMed

    Parry, Phillip Vaughan; Morales, Alejandro; Jankowitz, Brian Thomas

    2016-07-01

    The endovascular management of giant aneurysms often proves difficult with standard techniques. Obtaining distal access to allow catheter reduction is often key to approaching these aneurysms, but several anatomic challenges make this task unsafe and not feasible. Obtaining distal anchor points and performing catheter reduction maneuvers using adjunctive devices is not a novel concept, however using the Solitaire in order to do so may have some distinct advantages compared with previously described methods. Here we describe our novel Solitaire salvage technique, which allowed successful reduction of a looped catheter within an aneurysm in three cases. While this technique is expensive and therefore best performed after standard maneuvers have failed, in our experience it was effective, safe, and more efficient than other methods. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  10. Micro-computed tomography in murine models of cerebral cavernous malformations as a paradigm for brain disease.

    PubMed

    Girard, Romuald; Zeineddine, Hussein A; Orsbon, Courtney; Tan, Huan; Moore, Thomas; Hobson, Nick; Shenkar, Robert; Lightle, Rhonda; Shi, Changbin; Fam, Maged D; Cao, Ying; Shen, Le; Neander, April I; Rorrer, Autumn; Gallione, Carol; Tang, Alan T; Kahn, Mark L; Marchuk, Douglas A; Luo, Zhe-Xi; Awad, Issam A

    2016-09-15

    Cerebral cavernous malformations (CCMs) are hemorrhagic brain lesions, where murine models allow major mechanistic discoveries, ushering genetic manipulations and preclinical assessment of therapies. Histology for lesion counting and morphometry is essential yet tedious and time consuming. We herein describe the application and validations of X-ray micro-computed tomography (micro-CT), a non-destructive technique allowing three-dimensional CCM lesion count and volumetric measurements, in transgenic murine brains. We hereby describe a new contrast soaking technique not previously applied to murine models of CCM disease. Volumetric segmentation and image processing paradigm allowed for histologic correlations and quantitative validations not previously reported with the micro-CT technique in brain vascular disease. Twenty-two hyper-dense areas on micro-CT images, identified as CCM lesions, were matched by histology. The inter-rater reliability analysis showed strong consistency in the CCM lesion identification and staging (K=0.89, p<0.0001) between the two techniques. Micro-CT revealed a 29% greater CCM lesion detection efficiency, and 80% improved time efficiency. Serial integrated lesional area by histology showed a strong positive correlation with micro-CT estimated volume (r(2)=0.84, p<0.0001). Micro-CT allows high throughput assessment of lesion count and volume in pre-clinical murine models of CCM. This approach complements histology with improved accuracy and efficiency, and can be applied for lesion burden assessment in other brain diseases. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. UPLC-MSE Profiling of Phytoplankton Metabolites: Application to the Identification of Pigments and Structural Analysis of Metabolites in Porphyridium purpureum

    PubMed Central

    Juin, Camille; Bonnet, Antoine; Nicolau, Elodie; Bérard, Jean-Baptiste; Devillers, Romain; Thiéry, Valérie; Cadoret, Jean-Paul; Picot, Laurent

    2015-01-01

    A fast and high-resolution UPLC-MSE analysis was used to identify phytoplankton pigments in an ethanol extract of Porphyridium purpureum (Pp) devoid of phycobiliproteins. In a first step, 22 standard pigments were analyzed by UPLC-MSE to build a database including retention time and accurate masses of parent and fragment ions. Using this database, seven pigments or derivatives previously reported in Pp were unequivocally identified: β,β-carotene, chlorophyll a, zeaxanthin, chlorophyllide a, pheophorbide a, pheophytin a, and cryptoxanthin. Minor amounts of Divinyl chlorophyll a, a chemotaxonomic pigment marker for prochlorophytes, were also unequivocally identified using the database. Additional analysis of ionization and fragmentation patterns indicated the presence of ions that could correspond to hydroxylated derivatives of chlorophyll a and pheophytin a, produced during the ethanolic extraction, as well as previously described galactosyldiacylglycerols, the thylakoid coenzyme plastoquinone, and gracilamide B, a molecule previously reported in the red seaweed Gracillaria asiatica. These data point to UPLC-MSE as an efficient technique to identify phytoplankton pigments for which standards are available, and demonstrate its major interest as a complementary method for the structural elucidation of ionizable marine molecules. PMID:25913708

  12. Do work technique and musculoskeletal symptoms differ between men and women performing the same type of work tasks?

    PubMed

    Dahlberg, Raymond; Karlqvist, Lena; Bildt, Carina; Nykvist, Karin

    2004-11-01

    Musculoskeletal disorders are more common among women than among men. When comparing the difference between men and women in the prevalence of musculoskeletal disorders, methodological problems arise as men and women seldom perform the same type of activities, neither at work nor at home. The main objective of this cross-sectional case study was to compare work technique and self-reported musculoskeletal symptoms between men and women performing the same type of work tasks within a metal industry. Other factors, such as leisure activities, were also taken into consideration. Three data collection methods were used; questionnaire, interviews and systematic observations. The results from the observations revealed that women worked more frequently and during longer times with their hands above shoulder height than men. Working with hands above shoulder height is considered a risk factor for neck and shoulder disorders according to previous studies. Workplace design factors were probably a reason for differences in working technique between men and women. A higher proportion of women than men reported shoulder symptoms. Women spent more time on household activities than men, which indicates a higher total workload in paid and unpaid work.

  13. Differentially pumped spray deposition as a rapid screening tool for organic and perovskite solar cells.

    PubMed

    Jung, Yen-Sook; Hwang, Kyeongil; Scholes, Fiona H; Watkins, Scott E; Kim, Dong-Yu; Vak, Doojin

    2016-02-08

    We report a spray deposition technique as a screening tool for solution processed solar cells. A dual-feed spray nozzle is introduced to deposit donor and acceptor materials separately and to form blended films on substrates in situ. Using a differential pump system with a motorised spray nozzle, the effect of film thickness, solution flow rates and the blend ratio of donor and acceptor materials on device performance can be found in a single experiment. Using this method, polymer solar cells based on poly(3-hexylthiophene) (P3HT):(6,6)-phenyl C61 butyric acid methyl ester (PC61BM) are fabricated with numerous combinations of thicknesses and blend ratios. Results obtained from this technique show that the optimum ratio of materials is consistent with previously reported values confirming this technique is a very useful and effective screening method. This high throughput screening method is also used in a single-feed configuration. In the single-feed mode, methylammonium iodide solution is deposited on lead iodide films to create a photoactive layer of perovskite solar cells. Devices featuring a perovskite layer fabricated by this spray process demonstrated a power conversion efficiencies of up to 7.9%.

  14. Differentially pumped spray deposition as a rapid screening tool for organic and perovskite solar cells

    PubMed Central

    Jung, Yen-Sook; Hwang, Kyeongil; Scholes, Fiona H.; Watkins, Scott E.; Kim, Dong-Yu; Vak, Doojin

    2016-01-01

    We report a spray deposition technique as a screening tool for solution processed solar cells. A dual-feed spray nozzle is introduced to deposit donor and acceptor materials separately and to form blended films on substrates in situ. Using a differential pump system with a motorised spray nozzle, the effect of film thickness, solution flow rates and the blend ratio of donor and acceptor materials on device performance can be found in a single experiment. Using this method, polymer solar cells based on poly(3-hexylthiophene) (P3HT):(6,6)-phenyl C61 butyric acid methyl ester (PC61BM) are fabricated with numerous combinations of thicknesses and blend ratios. Results obtained from this technique show that the optimum ratio of materials is consistent with previously reported values confirming this technique is a very useful and effective screening method. This high throughput screening method is also used in a single-feed configuration. In the single-feed mode, methylammonium iodide solution is deposited on lead iodide films to create a photoactive layer of perovskite solar cells. Devices featuring a perovskite layer fabricated by this spray process demonstrated a power conversion efficiencies of up to 7.9%. PMID:26853266

  15. Effect of background correction on peak detection and quantification in online comprehensive two-dimensional liquid chromatography using diode array detection.

    PubMed

    Allen, Robert C; John, Mallory G; Rutan, Sarah C; Filgueira, Marcelo R; Carr, Peter W

    2012-09-07

    A singular value decomposition-based background correction (SVD-BC) technique is proposed for the reduction of background contributions in online comprehensive two-dimensional liquid chromatography (LC×LC) data. The SVD-BC technique was compared to simply subtracting a blank chromatogram from a sample chromatogram and to a previously reported background correction technique for one dimensional chromatography, which uses an asymmetric weighted least squares (AWLS) approach. AWLS was the only background correction technique to completely remove the background artifacts from the samples as evaluated by visual inspection. However, the SVD-BC technique greatly reduced or eliminated the background artifacts as well and preserved the peak intensity better than AWLS. The loss in peak intensity by AWLS resulted in lower peak counts at the detection thresholds established using standards samples. However, the SVD-BC technique was found to introduce noise which led to detection of false peaks at the lower detection thresholds. As a result, the AWLS technique gave more precise peak counts than the SVD-BC technique, particularly at the lower detection thresholds. While the AWLS technique resulted in more consistent percent residual standard deviation values, a statistical improvement in peak quantification after background correction was not found regardless of the background correction technique used. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Chronic pancreatitis.

    PubMed

    Yang, Dennis; Forsmark, Chris E

    2017-09-01

    Summarize key clinical advances in chronic pancreatitis reported in 2016. Early diagnosis of chronic pancreatitis remains elusive. Recent studies suggest that endoscopic ultrasound may be less accurate than previously thought and new MRI techniques may be helpful. Genetic predisposition may independently affect the clinical course of chronic pancreatitis and the risk for pancreatic cancer. Cigarette smoking may have a greater negative impact on chronic pancreatitis than previously thought and moderate alcohol consumption may be protective. A multidisciplinary approach is necessary for the treatment of type 3 diabetes and nutritional deficiencies in chronic pancreatitis. Although endoscopic therapy remains a reasonable first-line option in treating chronic pancreatitis and its complications, early surgical intervention may be indicated for pain in select patients. Newer endoscopic ultrasound and MRI techniques are being evaluated to help with the early diagnosis of chronic pancreatitis. Both genetic predisposition and cigarette smoking are increasingly recognized as having a major impact in the course of the disease and the risk for pancreatic cancer. Endoscopic therapy is well tolerated and effective for the treatment of chronic pancreatitis and its complications although an early surgical approach for pain may be associated with improved clinical outcomes.

  17. Brain Stem Cavernous Malformations: Operative Nuances of a Less-Invasive Resection Technique.

    PubMed

    Singh, Harminder; Elarjani, Turki; da Silva, Harley Brito; Shetty, Rakshith; Kim, Louis; Sekhar, Laligam N

    2017-12-08

    Different operative techniques are reported for the resection of brainstem cavernous malformations (BSCMs). The senior author has previously reported on a less-invasive technique of entering the brain stem with piecemeal removal of BSCMs, especially the deep-seated ones. To present a larger series of these lesions, emphasizing the approach to the brain stem via case selection. We discuss the nuances of the less-invasive operative technique through case illustrations and intraoperative videos. A retrospective review of 46 consecutive cases of BSCMs, with their clinical and radiographic data, was performed. Nine cases were selected to illustrate 7 different operative approaches, and discuss surgical nuances of the less-invasive technique unique to each. Postoperative morbidity, defined as an increase in modified Rankin Scale, was observed in 5 patients (10.9%). A residual BSCM was present in 2 patients (4.3%); both underwent reoperation to remove the remainder. At follow-up of 31.1 ± 27.8 mo, 3 patients experienced recurrence (6.5%). Overall, 65% of our patients improved, 20% stayed the same, and 11% worsened postsurgery. Two patients died, yielding a mortality of 4.3%. Using the less-invasive resection technique for piecemeal BSCM removal, in appropriately selected patients, has yielded comparable to improved patient outcomes over existing large series. In our experience, lateral, anterolateral, and posterolateral approaches are favorable over direct midline (dorsal or ventral) approaches. A thorough understanding of brain-stem safe-entry zones, in conjunction with appropriate approach selection, is key to a good outcome in challenging cases. Copyright © 2017 by the Congress of Neurological Surgeons

  18. A multiplanar complex resection of a low-grade chondrosarcoma of the distal femur guided by K-wires previously inserted under CT-guide: a case report.

    PubMed

    Zoccali, Carmine; Rossi, Barbara; Ferraresi, Virginia; Anelli, Vincenzo; Rita, Alessandro

    2014-08-13

    In muscular skeletal oncology aiming to achieve wide surgical margin is one of the main factors influencing patient prognosis. In cases where lesions are either meta or epiphyseal, surgery most often compromises joint integrity and stability because muscles, tendons and ligaments are involved in wide resection. When lesions are well circumscribed they can be completely resected by performing multi-planar osteotomies guided by computer-assisted navigation. We describe a case of low-grade chondrosarcoma of the distal femur where a simple but effective technique was useful to perform complex multiplanar osteotomies. No similar techniques are reported in the literature. A 57 year-old Caucasian female was referred to our department for the presence of a distal femur chondrosarcoma. A resection with the presenting technique was scheduled. The first step consists of inserting several K-wires under CT-scan control to delimitate the tumor; the second step consists of tumor removal: in operative theatre, following surgical access, k-wires are used as guide positioning; scalpels are externally placed to k-wires to perform a safe osteotomy. Computed assisted resections can be considered the most advantageous method to reach the best surgical outcome; unfortunately navigation systems are only available in specialized centres. The present technique allows for a multiplanar complex resection when navigation systems are not available. This technique can be applied in low-grade tumours where a minimal wide margin can be considered sufficient.

  19. The first 4p euchromatic variant in a healthy carrier having an unusual reproductive history.

    PubMed

    Rodríguez, L; Zollino, M; Mansilla, E; Martínez-Fernández, M L; Pérez, P; Murdolo, M; Martínez-Frías, M L

    2007-05-01

    We report on the molecular cytogenetics studies in a healthy couple who had had three pregnancies which ended in a termination of pregnancy (TOP). In two of them, prenatal sonogram showed fetal dwarfism and in the third one, a chromosome alteration was found in the amniocentesis. A previous pregnancy ended in a healthy girl. A high-resolution G-band karyotype (550-850 bands), together with Fluorescence in situ Hybridization (FISH) techniques, detected in the father a 4p interstitial euchromatic duplication. This chromosome duplication appears to be a previously undescribed euchromatic variant (EV). We discuss the possibility that the 4p paternal EV could be involved in the clinical and genetic findings of the three TOPs.

  20. SINE sequences detect DNA fingerprints in salmonid fishes.

    PubMed

    Spruell, P; Thorgaard, G H

    1996-04-01

    DNA probes homologous to two previously described salmonid short interspersed nuclear elements (SINEs) detected DNA fingerprint patterns in 14 species of salmonid fishes. The probes showed more homology to some species than to others and little homology to three nonsalmonid fishes. The DNA fingerprint patterns derived from the SINE probes are individual-specific and inherited in a Mendelian manner. Probes derived from different regions of the same SINE detect only partially overlapping banding patterns, reflecting a more complex SINE structure than has been previously reported. Like the human Alu sequence, the SINEs found in salmonids could provide useful genetic markers and primer sites for PCR-based techniques. These elements may be more desirable for some applications than traditional DNA fingerprinting probes that detect tandemly repeated arrays.

  1. Stress Management and Relaxation Techniques use among underserved inpatients in an inner city hospital.

    PubMed

    Gardiner, Paula; Sadikova, Ekaterina; Filippelli, Amanda C; Mitchell, Suzanne; White, Laura F; Saper, Robert; Kaptchuk, Ted J; Jack, Brian W; Fredman, Lisa

    2015-06-01

    Little is known about the use of Stress Management and Relaxation Techniques (SMART) in racially diverse inpatients. We hope to identify socioeconomic status (SES) factors, health behavior factors, and clinical factors associated with the use of SMART. We conducted a secondary analysis of baseline data from 623 hospitalized patients enrolled in the Re-Engineered Discharge (RED) clinical trial. We assessed socio-demographic characteristics and use of SMART. We used bivariate and multivariate logistic regression to test the association of SMART with socio-demographic characteristics, health behaviors, and clinical factors. A total of 26.6% of participants reported using SMART and 23.6% used mind body techniques. Thirty six percent of work disabled patients, 39% of illicit drug users, and 38% of participants with depressive symptoms used SMART. Patients who both reported illicit drug use and screened positive for depression had significantly increased odds of using SMART [OR=4.94, 95% CI (1.59, 15.13)]. Compared to non-Hispanic whites, non-Hispanic blacks [0.55 (0.34-0.87)] and Hispanic/other race individuals [0.40 (0.20-0.76)] were less likely to use SMART. We found greater utilization of SMART among all racial groups compared to previous national studies. In the inner city inpatient setting, patients with depression, illicit drug use, and work disability reported higher rates of using SMART. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Analysis of airfoil transitional separation bubbles

    NASA Technical Reports Server (NTRS)

    Davis, R. L.; Carter, J. E.

    1984-01-01

    A previously developed local inviscid-viscous interaction technique for the analysis of airfoil transitional separation bubbles, ALESEP (Airfoil Leading Edge Separation) has been modified to utilize a more accurate windward finite difference procedure in the reversed flow region, and a natural transition/turbulence model has been incorporated for the prediction of transition within the separation bubble. Numerous calculations and experimental comparisons are presented to demonstrate the effects of the windward differencing scheme and the natural transition/turbulence model. Grid sensitivity and convergence capabilities of this inviscid-viscous interaction technique are briefly addressed. A major contribution of this report is that with the use of windward differencing, a second, counter-rotating eddy has been found to exist in the wall layer of the primary separation bubble.

  3. An investigation into underwater wet welding using the flux cored arc welding process

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brydon, A.M.; Nixon, J.H.

    1995-12-31

    For the last two years, Cranfield has been carrying out a program of process investigations into wet underwater welding (Graham and Nixon 1993, Nixon and Webb 1994), and has demonstrated that it is possible to markedly improve the stability and consistency of the process by using control techniques developed for hyperbaric welding. In the project reported below, an initial evaluation of wet flux cored arc welding was undertaken. Although there continues to be considerable resistance to the use of wet welding on structures in the North Sea, continued pressure to reduce repair and maintenance costs is causing the industry tomore » re-examine techniques previously discounted, such as wet welding (Anon 1993).« less

  4. Nanoparticle coated optical fibers for single microbubble generation

    NASA Astrophysics Data System (ADS)

    Pimentel-Domínguez, Reinher; Hernández-Cordero, Juan

    2011-09-01

    The study of bubbles and bubbly flows is important in various fields such as physics, chemistry, medicine, geophysics, and even the food industry. A wide variety of mechanical and acoustic techniques have been reported for bubble generation. Although a single bubble may be generated with these techniques, controlling the size and the mean lifetime of the bubble remains a difficult task. Most of the optical methods for generation of microbubbles involve high-power pulsed laser sources focused in absorbing media such as liquids or particle solutions. With these techniques, single micron-sized bubbles can be generated with typical mean lifetimes ranging from nano to microseconds. The main problem with these bubbles is their abrupt implosion: this produces a shock wave that can potentially produce damages on the surroundings. These effects have to be carefully controlled in biological applications and in laser surgery, but thus far, not many options are available to effectively control micron-size bubble growth. In this paper, we present a new technique to generate microbubbles in non-absorbing liquids. In contrast to previous reports, the proposed technique uses low-power and a CW radiation from a laser diode. The laser light is guided through an optical fiber whose output end has been coated with nanostructures. Upon immersing the tip of the fiber in ethanol or water, micron-size bubbles can be readily generated. With this technique, bubble growth can be controlled through adjustments on the laser power. We have obtained micron-sized bubbles with mean lifetimes in the range of seconds. Furthermore, the generated bubbles do not implode, as verified with a high-speed camera and flow visualization techniques.

  5. Initial sequence characterization of the rhabdoviruses of squamate reptiles, including a novel rhabdovirus from a caiman lizard (Dracaena guianensis).

    PubMed

    Wellehan, James F X; Pessier, Allan P; Archer, Linda L; Childress, April L; Jacobson, Elliott R; Tesh, Robert B

    2012-08-17

    Rhabdoviruses infect a variety of hosts, including non-avian reptiles. Consensus PCR techniques were used to obtain partial RNA-dependent RNA polymerase gene sequence from five rhabdoviruses of South American lizards; Marco, Chaco, Timbo, Sena Madureira, and a rhabdovirus from a caiman lizard (Dracaena guianensis). The caiman lizard rhabdovirus formed inclusions in erythrocytes, which may be a route for infecting hematophagous insects. This is the first information on behavior of a rhabdovirus in squamates. We also obtained sequence from two rhabdoviruses of Australian lizards, confirming previous Charleville virus sequence and finding that, unlike a previous sequence report but in agreement with serologic reports, Almpiwar virus is clearly distinct from Charleville virus. Bayesian and maximum likelihood phylogenetic analysis revealed that most known rhabdoviruses of squamates cluster in the Almpiwar subgroup. The exception is Marco virus, which is found in the Hart Park group. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Summary of synfuel characterization and combustion studies

    NASA Technical Reports Server (NTRS)

    Schultz, D. F.

    1983-01-01

    Combustion component research studies aimed at evolving environmentally acceptable approaches for burning coal derived fuels for ground power applications were performed at the NASA Lewis Research Center under a program titled the ""Critical Research and Support Technology Program'' (CRT). The work was funded by the Department of Energy and was performed in four tasks. This report summarizes these tasks which have all been previously reported. In addition some previously unreported data from Task 4 is also presented. The first, Task 1 consisted of a literature survey aimed at determining the properties of synthetic fuels. This was followed by a computer modeling effort, Task 2, to predict the exhaust emissions resulting from burning coal liquids by various combustion techniques such as lean and rich-lean combustion. The computer predictions were then compared to the results of a flame tube rig, Task 3, in which the fuel properties were varied to simulate coal liquids. Two actual SRC 2 coal liquids were tested in this flame tube task.

  7. Analysis of cell mechanics in single vinculin-deficient cells using a magnetic tweezer

    NASA Technical Reports Server (NTRS)

    Alenghat, F. J.; Fabry, B.; Tsai, K. Y.; Goldmann, W. H.; Ingber, D. E.

    2000-01-01

    A magnetic tweezer was constructed to apply controlled tensional forces (10 pN to greater than 1 nN) to transmembrane receptors via bound ligand-coated microbeadswhile optically measuring lateral bead displacements within individual cells. Use of this system with wild-type F9 embryonic carcinoma cells and cells from a vinculin knockout mouse F9 Vin (-/-) revealed much larger differences in the stiffness of the transmembrane integrin linkages to the cytoskeleton than previously reported using related techniques that measured average mechanical properties of large cell populations. The mechanical properties measured varied widely among cells, exhibiting an approximately log-normal distribution. The median lateral bead displacement was 2-fold larger in F9 Vin (-/-) cells compared to wild-type cells whereas the arithmetic mean displacement only increased by 37%. We conclude that vinculin serves a greater mechanical role in cells than previously reported and that this magnetic tweezer device may be useful for probing the molecular basis of cell mechanics within single cells. Copyright 2000 Academic Press.

  8. Adaptive Optics Imaging in Laser Pointer Maculopathy.

    PubMed

    Sheyman, Alan T; Nesper, Peter L; Fawzi, Amani A; Jampol, Lee M

    2016-08-01

    The authors report multimodal imaging including adaptive optics scanning laser ophthalmoscopy (AOSLO) (Apaeros retinal image system AOSLO prototype; Boston Micromachines Corporation, Boston, MA) in a case of previously diagnosed unilateral acute idiopathic maculopathy (UAIM) that demonstrated features of laser pointer maculopathy. The authors also show the adaptive optics images of a laser pointer maculopathy case previously reported. A 15-year-old girl was referred for the evaluation of a maculopathy suspected to be UAIM. The authors reviewed the patient's history and obtained fluorescein angiography, autofluorescence, optical coherence tomography, infrared reflectance, and AOSLO. The time course of disease and clinical examination did not fit with UAIM, but the linear pattern of lesions was suspicious for self-inflicted laser pointer injury. This was confirmed on subsequent questioning of the patient. The presence of linear lesions in the macula that are best highlighted with multimodal imaging techniques should alert the physician to the possibility of laser pointer injury. AOSLO further characterizes photoreceptor damage in this condition. [Ophthalmic Surg Lasers Imaging Retina. 2016;47:782-785.]. Copyright 2016, SLACK Incorporated.

  9. Divers models of divalent cation interaction to calcium-binding proteins: techniques and anthology.

    PubMed

    Cox, Jos A

    2013-01-01

    Intracellular Ca(2+)-binding proteins (CaBPs) are sensors of the calcium signal and several of them even shape the signal. Most of them are equipped with at least two EF-hand motifs designed to bind Ca(2+). Their affinities are very variable, can display cooperative effects, and can be modulated by physiological Mg(2+) concentrations. These binding phenomena are monitored by four major techniques: equilibrium dialysis, fluorimetry with fluorescent Ca(2+) indicators, flow dialysis, and isothermal titration calorimetry. In the last quarter of the twentieth century reports on the ion-binding characteristics of several abundant wild-type CaBPs were published. With the advent of recombinant CaBPs it became possible to determine these properties on previously inaccessible proteins. Here I report on studies by our group carried out in the last decade on eight families of recombinant CaBPs, their mutants, or truncated domains. Moreover this chapter deals with the currently used methods for quantifying the binding of Ca(2+) and Mg(2+) to CaBPs.

  10. Successful Treatment of Early Talar Osteonecrosis by Core Decompression Combined with Intraosseous Stem Cell Injection: A Case Report.

    PubMed

    Nevalainen, Mika T; Repo, Jussi P; Pesola, Maija; Nyrhinen, Jukka P

    2018-01-01

    Osteonecrosis of the talus is a fairly rare condition. Many predisposing factors have been identified including previous trauma, use of corticosteroids, alcoholism, and smoking. As a gold standard, magnetic resonance imaging (MRI) is the most sensitive and specific diagnostic examination to detect osteonecrosis. While many treatment options for talar osteonecrosis exist, core decompression is suggested on young patients with good outcome results. More recently, intraosseous stem cell and platelet-rich plasma (PRP) injection has been added to the core decompression procedure. We report a successful treatment of early talar osteonecrosis ARCO I (Association Research Circulation Osseous) by core decompression combined with stem cell and PRP injection. On 3-month and 15-month follow-up, MRI showed complete resolution of the osteonecrotic changes together with clinical improvement. This modified technique is a viable treatment option for early talar osteonecrosis. Nevertheless, future prospects should include a study comparing this combined technique with plain core decompression.

  11. Review of PWR fuel rod waterside corrosion behavior

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garzarolli, F.; Jorde, D.; Manzel, R.

    Waterside corrosion of Zircaloy has generally not been a problem under normal PWR operating conditions, although some instances of accelerated corrosion have been reported. However, an incentive exists to extend the average fuel rod discharge burnups to about 50,000 MWd/MTU. To minimize corrosion at these extended burnups, the factors which influence Zircaloy corrosion need to be better understood. A data base of Zircaloy corrosion behavior under PWR operating conditions has been established. The data are compiled previously published reports as well as from new Kraftwerk Union examinations. A non-destructive eddy-current technique is used to measure the oxide layer thickness onmore » fuel rods. Comparisons of measuremnts made using this eddy-current technique with those made by usual metallographic methods indicate good agreement. The data were evaluated by defining a fitting factor F which describes the increase in corrosion rate observed in-reactor over that observed from measurements of ex-reactor corrosion coupons.« less

  12. Forensic Facial Reconstruction: The Final Frontier.

    PubMed

    Gupta, Sonia; Gupta, Vineeta; Vij, Hitesh; Vij, Ruchieka; Tyagi, Nutan

    2015-09-01

    Forensic facial reconstruction can be used to identify unknown human remains when other techniques fail. Through this article, we attempt to review the different methods of facial reconstruction reported in literature. There are several techniques of doing facial reconstruction, which vary from two dimensional drawings to three dimensional clay models. With the advancement in 3D technology, a rapid, efficient and cost effective computerized 3D forensic facial reconstruction method has been developed which has brought down the degree of error previously encountered. There are several methods of manual facial reconstruction but the combination Manchester method has been reported to be the best and most accurate method for the positive recognition of an individual. Recognition allows the involved government agencies to make a list of suspected victims'. This list can then be narrowed down and a positive identification may be given by the more conventional method of forensic medicine. Facial reconstruction allows visual identification by the individual's family and associates to become easy and more definite.

  13. Intestinal volvulus following laparoscopic surgery: a literature review and case report.

    PubMed

    Ferguson, Louise; Higgs, Zoe; Brown, Sylvia; McCarter, Douglas; McKay, Colin

    2008-06-01

    Since its introduction in the early 1990s, the laparoscopic cholecystectomy has become the standard surgical intervention for cholelithiasis. The laparoscopic technique is being used in an increasing number of abdominal procedures. Intestinal volvulus is a rare complication of laparoscopic procedures, such as the laparoscopic cholecystectomy. A review of the literature revealed 12 reports of this complication occurring without a clear cause. Etiologic factors that have been postulated include congenital malrotation, previous surgery, and intraoperative factors, such as pneumoperitoneum, mobilization of the bowel, and patient position. In this paper, we review the literature for this rare complication and report on a case of cecal bascule (a type of cecal volvulus) occurring following the laparoscopic cholecystectomy. Of the 12 prior reports of intestinal volvulus following laparoscopic procedures, 8 of these followed the laparoscopic cholecystectomy, of which two were cecal volvulae. This is the first reported case of a cecal bascule occurring following the laparoscopic cholecystectomy.

  14. A rare chemical burn due to Ranunculus arvensis: three case reports.

    PubMed

    Kocak, Abdullah O; Saritemur, Murat; Atac, Kenan; Guclu, Sibel; Ozlu, Ibrahim

    2016-01-01

    Ranunculus arvensis, a plant that is a member of Ranunculaceae family, generally used for local treatment of joint pain, muscle pain, burns, lacerations, edema, abscess drainage, hemorrhoids, and warts among the population. In this case report, we presented three patients who developed chemical skin burns after using R. arvensis plant locally for knee pain. The destructive effect of the plant has been reported previously to be more in fresh plants and less in dried plants. Although protoanemonin, which is considered as the main toxic substance, was reported to be absent in dried or boiled plants, the plant was boiled, cooled, and wrapped over the region with pain in our cases. Therefore, we thought that protoanemonin may be considered to be heat resistant. Also, the burn management proceeded up to surgery by using the flap technique in one of our patients in contrast to the cases found in published reports who were treated by antibiotics and dressings.

  15. Therapeutic interventions employed by Greater Toronto Area chiropractors on pregnant patients: results of a cross-sectional online survey

    PubMed Central

    Yuen, Tammy; Wells, Kayla; Benoit, Samantha; Yohanathan, Sahila; Capelletti, Lauren; Stuber, Kent

    2013-01-01

    Introduction: Due to different biomechanical, nutritional, and hormonal considerations, it is possible that chiropractors may employ different therapeutic interventions and recommendations for pregnant patients than non-pregnant ones. The objective of this study was to determine the therapeutic interventions that chiropractors who are members of the Ontario Chiropractic Association in the Greater Toronto Area most commonly provide to pregnant patients. Methods: An introductory e-mail was sent in October 2011 to 755 members of the Ontario Chiropractic Association within the Greater Toronto Area five days prior to a 15 question survey being distributed via e-mail. Reminder e-mails were sent 13 days and 27 days later. Using descriptive statistics, demographic information was reported along with reported use of different treatments and recommendations for pregnant patients Results: A response rate of 23% was obtained. The majority of the respondents (90%) reported using the Diversified technique on pregnant patients, followed by soft tissue therapy (62%) and Activator (42%). The most common adjunctive therapy recommended to pregnant patients was referral to massage therapy (90%). Most of the respondents (92%) indicated that they prescribe stretching exercises to pregnant patients and recommend a multivitamin (84%) or folic acid (81%) to pregnant patients. Conclusion: In agreement with previous research on chiropractic technique usage on non-pregnant patients, the majority of respondents indicated treating pregnant patients with the Diversified technique, with other chiropractic techniques being utilized at varying rates on pregnant patients. Most respondents indicated prescribing exercise, and making adjunctive and nutritional recommendations frequently for their pregnant patients. PMID:23754858

  16. Rate constant for reaction of atomic hydrogen with germane

    NASA Technical Reports Server (NTRS)

    Nava, David F.; Payne, Walter A.; Marston, George; Stief, Louis J.

    1990-01-01

    Due to the interest in the chemistry of germane in the atmospheres of Jupiter and Saturn, and because previously reported kinetic reaction rate studies at 298 K gave results differing by a factor of 200, laboratory measurements were performed to determine the reaction rate constant for H + GeH4. Results of the study at 298 K, obtained via the direct technique of flash photolysis-resonance fluorescence, yield the reaction rate constant, k = (4.08 + or - 0.22) x 10(exp -12) cu cm/s.

  17. Recanalisation of Chronically Occluded Remote Superficial Femoral Artery Endarterectomy Through Angioplasty for Limb Salvage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Husainy, Mohammad Ali, E-mail: m.husainy@nhs.net; Slim, Hani; Rashid, Hisham

    2017-02-15

    We report a novel application of balloon angioplasty to recanalise a chronically occluded remote endarterectomy superficial femoral artery. This patient previously had two occluded surgical bypass grafts in an attempt to revascularise the limb and presented with critical limb ischaemia and necrotic foot ulcerations. Following the angioplasty, the patient showed significant improvement in rest pain and healing of the ulcerations. This technique may be useful for limb salvage in patients where surgical options have been exhausted.

  18. Cavity Detection and Delineation Research. Report 5. Electromagnetic (Radar) Techniques Applied to Cavity Detection.

    DTIC Science & Technology

    1983-07-01

    tranverse lines, all of which overlapped test areas previously investigated by Technos. The lines were chosen to be representative of cavity areas and...cavities and may be con- sidered as competent rock for this site. It is interesting to note that amplitude perturbations do appear in the zone 95 to 100 ft...tunnels are man-made (regular in shape) and are in reasonably competent rock (not heavily fractured), the tunnel signature wiil be quite evident and

  19. A numerical solution for thermoacoustic convection of fluids in low gravity

    NASA Technical Reports Server (NTRS)

    Spradley, L. W.; Bourgeois, S. V., Jr.; Fan, C.; Grodzka, P. G.

    1973-01-01

    A finite difference numerical technique for solving the differential equations which describe thermal convection of compressible fluids in low gravity are reported. Results of one-dimensional calculations are presented, and comparisons are made to previous solutions. The primary result presented is a one-dimensional radial model of the Apollo 14 heat flow and convection demonstration flight experiment. The numerical calculations show that thermally induced convective motion in a confined fluid can have significant effects on heat transfer in a low gravity environment.

  20. Application of imaging to the atmospheric Cherenkov technique

    NASA Technical Reports Server (NTRS)

    Cawley, M. F.; Fegan, D. J.; Gibbs, K.; Gorham, P. W.; Hillas, A. M.; Lamb, R. C.; Liebing, D. F.; Mackeown, P. K.; Porter, N. A.; Stenger, V. J.

    1985-01-01

    Turver and Weekes proposed using a system of phototubes in the focal plane of a large reflector to give an air Cherenkov camera for gamma ray astronomy. Preliminary results with a 19 element camera have been reported previously. In 1983 the camera was increased to 37 pixels; it has now been routinely operated for two years. A brief physical description of the camera, its mode of operation, and the data reduction procedures are presented. The Monte Carlo simultations on which these are based on also reviewed.

  1. Influence of Grain Structure and Doping on the Deformation and Fracture of Polycrystalline Silicon for MEMS and NEMS

    DTIC Science & Technology

    2012-09-03

    described in previous reports [32]. In this experimental technique, the specimen ends are gripped to loadcell and PZT actuator mounted on three dimensional...shown in Figure 3. This was due to the random distribution of columnar grains with different texture where KIC was dependent on one particular grain...Engineering: A, 268 (1-2), pp. 116-126, 1999 [19] C.P. Chen, and M.H. Leipold, "Fracture toughness of silicon", American Ceramics Society Bulletin

  2. How I report breast magnetic resonance imaging studies for breast cancer staging and screening.

    PubMed

    Vinnicombe, Sarah

    2016-07-25

    Magnetic resonance imaging (MRI) of the breast is the most sensitive imaging technique for the diagnosis and local staging of primary breast cancer and yet, despite the fact that it has been in use for 20 years, there is little evidence that its widespread uncritical adoption has had a positive impact on patient-related outcomes.This has been attributed previously to the low specificity that might be expected with such a sensitive modality, but with modern techniques and protocols, the specificity and positive predictive value for malignancy can exceed that of breast ultrasound and mammography. A more likely explanation is that historically, clinicians have acted on MRI findings and altered surgical plans without prior histological confirmation. Furthermore, modern adjuvant therapy for breast cancer has improved so much that it has become a very tall order to show a an improvement in outcomes such as local recurrence rates.In order to obtain clinically useful information, it is necessary to understand the strengths and weaknesses of the technique and the physiological processes reflected in breast MRI. An appropriate indication for the scan, proper patient preparation and good scan technique, with rigorous quality assurance, are all essential prerequisites for a diagnostically relevant study.The use of recognised descriptors from a standardised lexicon is helpful, since assessment can then dictate subsequent recommendations for management, as in the American College of Radiology BI-RADS (Breast Imaging Reporting and Data System) lexicon (Morris et al., ACR BI-RADS® Atlas, Breast Imaging Reporting and Data System, 2013). It also enables audit of the service. However, perhaps the most critical factor in the generation of a meaningful report is for the reporting radiologist to have a thorough understanding of the clinical question and of the findings that will influence management. This has never been more important than at present, when we are in the throes of a remarkable paradigm shift in the treatment of both early stage and locally advanced breast cancer.

  3. Electrostatic-Force-Assisted Dispensing Printing to Construct High-Aspect-Ratio of 0.79 Electrodes on a Textured Surface with Improved Adhesion and Contact Resistivity

    PubMed Central

    Shin, Dong-Youn; Yoo, Sung-Soo; Song, Hee-eun; Tak, Hyowon; Byun, Doyoung

    2015-01-01

    As a novel route to construct fine and abnormally high-aspect-ratio electrodes with excellent adhesion and reduced contact resistivity on a textured surface, an electrostatic-force-assisted dispensing printing technique is reported and compared with conventional dispensing and electrohydrodynamic jet printing techniques. The electrostatic force applied between a silver paste and the textured surface of a crystalline silicon solar cell wafer significantly improves the physical adhesion of the electrodes, whereas those fabricated using a conventional dispensing printing technique peel off with a silver paste containing 2 wt% of a fluorosurfactant. Moreover, the contact resistivity and dimensionless deviation of total resistance are significantly reduced from 2.19 ± 1.53 mΩ·cm2 to 0.98 ± 0.92 mΩ·cm2 and from 0.10 to 0.03, respectively. By utilizing electrodes with an abnormally high-aspect-ratio of 0.79 (the measured thickness and width are 30.4 μm and 38.3 μm, respectively), the cell efficiency is 17.2% on a polycrystalline silicon solar cell with an emitter sheet resistance of 60 Ω/sq. This cell efficiency is considerably higher than previously reported values obtained using a conventional electrohydrodynamic jet printing technique, by +0.48–3.5%p. PMID:26576857

  4. Hybrid Technique for Cranial Defect Reconstruction: Surgical Results over a 10-Year Period in a Single Institution.

    PubMed

    Guerrero-Suarez, Pablo David; Guerrero-López, Paola; Ortiz-Leon, Abarin; Sosa-Castillo, Haydee Samantha; Velazquez-Gonzalez, Lenny Marlene; Martinez-Anda, Jaime Jesus

    2018-06-11

    Decompressive craniectomy is an urgent procedure that is increasingly used for treatment of intracranial hypertension. After recovery, reconstruction of the cranial defect is necessary. Cranioplasty is an elective procedure with a high potential for morbidity if care is not taken on different surgical factors such as the material used as the cranial flap. In Latin America, high costs in some materials used in cranioplasty make its use prohibitive for some patients and institutions, and looking for alternatives has become a priority in neurosurgical centers. An autologous bone flap is an excellent option possessing the characteristics of an ideal material for cranioplasty. Nevertheless, its use is associated with high morbidity and flap failure. We report our mono-institutional experience in a 10-year period of a hybrid technique for cranioplasty using an autologous bone flap with titanium plates. Sixty-five patients underwent the technique, with good cosmetic results in 89.2% and success in functional result in 90.8% of patients . No significant statistical differences were found on the timing of the surgery or the location of the cranial defect. We had a 1.5% rate of surgical site infection, less than that reported on previous series. We propose that the hybrid technique of cranioplasty is a safety and effective option for cranial defect reconstruction. Georg Thieme Verlag KG Stuttgart · New York.

  5. Sub-barrier radioactive ion beam investigations using a new methodology and analysis for the stacked target technique

    NASA Astrophysics Data System (ADS)

    Fisichella, M.; Shotter, A. C.; Di Pietro, A.; Figuera, P.; Lattuada, M.; Marchetta, C.; Privitera, V.; Romano, L.; Ruiz, C.; Zadro, M.

    2015-12-01

    For low energy reaction studies involving radioactive ion beams, the experimental reaction yields are generally small due to the low intensity of the beams. For this reason, the stacked target technique has been often used to measure excitation functions. This technique offers considerable advantages since the reaction cross-section at several energies can be simultaneously measured. In a further effort to increase yields, thick targets are also employed. The main disadvantage of the method is the degradation of the beam quality as it passes through the stack due to the statistical nature of energy loss processes and any nonuniformity of the stacked targets. This degradation can lead to ambiguities of associating effective beam energies to reaction product yields for the targets within the stack and, as a consequence, to an error in the determination of the excitation function for the reaction under study. A thorough investigation of these ambiguities is reported, and a best practice procedure of analyzing data obtained using the stacked target technique with radioactive ion beams is recommended. Using this procedure a re-evaluation is reported of some previously published sub-barrier fusion data in order to demonstrate the possibility of misinterpretations of derived excitation functions. In addition, this best practice procedure has been used to evaluate, from a new data set, the sub-barrier fusion excitation function for the reaction 6Li+120Sn .

  6. Alternative Constraint Handling Technique for Four-Bar Linkage Path Generation

    NASA Astrophysics Data System (ADS)

    Sleesongsom, S.; Bureerat, S.

    2018-03-01

    This paper proposes an extension of a new concept for path generation from our previous work by adding a new constraint handling technique. The propose technique was initially designed for problems without prescribed timing by avoiding the timing constraint, while remain constraints are solving with a new constraint handling technique. The technique is one kind of penalty technique. The comparative study is optimisation of path generation problems are solved using self-adaptive population size teaching-learning based optimization (SAP-TLBO) and original TLBO. In this study, two traditional path generation test problem are used to test the proposed technique. The results show that the new technique can be applied with the path generation problem without prescribed timing and gives better results than the previous technique. Furthermore, SAP-TLBO outperforms the original one.

  7. Propagation-based x-ray phase contrast imaging using an iterative phase diversity technique

    NASA Astrophysics Data System (ADS)

    Carroll, Aidan J.; van Riessen, Grant A.; Balaur, Eugeniu; Dolbnya, Igor P.; Tran, Giang N.; Peele, Andrew G.

    2018-03-01

    Through the use of a phase diversity technique, we demonstrate a near-field in-line x-ray phase contrast algorithm that provides improved object reconstruction when compared to our previous iterative methods for a homogeneous sample. Like our previous methods, the new technique uses the sample refractive index distribution during the reconstruction process. The technique complements existing monochromatic and polychromatic methods and is useful in situations where experimental phase contrast data is affected by noise.

  8. Combining heuristic and statistical techniques in landslide hazard assessments

    NASA Astrophysics Data System (ADS)

    Cepeda, Jose; Schwendtner, Barbara; Quan, Byron; Nadim, Farrokh; Diaz, Manuel; Molina, Giovanni

    2014-05-01

    As a contribution to the Global Assessment Report 2013 - GAR2013, coordinated by the United Nations International Strategy for Disaster Reduction - UNISDR, a drill-down exercise for landslide hazard assessment was carried out by entering the results of both heuristic and statistical techniques into a new but simple combination rule. The data available for this evaluation included landslide inventories, both historical and event-based. In addition to the application of a heuristic method used in the previous editions of GAR, the availability of inventories motivated the use of statistical methods. The heuristic technique is largely based on the Mora & Vahrson method, which estimates hazard as the product of susceptibility and triggering factors, where classes are weighted based on expert judgment and experience. Two statistical methods were also applied: the landslide index method, which estimates weights of the classes for the susceptibility and triggering factors based on the evidence provided by the density of landslides in each class of the factors; and the weights of evidence method, which extends the previous technique to include both positive and negative evidence of landslide occurrence in the estimation of weights for the classes. One key aspect during the hazard evaluation was the decision on the methodology to be chosen for the final assessment. Instead of opting for a single methodology, it was decided to combine the results of the three implemented techniques using a combination rule based on a normalization of the results of each method. The hazard evaluation was performed for both earthquake- and rainfall-induced landslides. The country chosen for the drill-down exercise was El Salvador. The results indicate that highest hazard levels are concentrated along the central volcanic chain and at the centre of the northern mountains.

  9. Method: automatic segmentation of mitochondria utilizing patch classification, contour pair classification, and automatically seeded level sets

    PubMed Central

    2012-01-01

    Background While progress has been made to develop automatic segmentation techniques for mitochondria, there remains a need for more accurate and robust techniques to delineate mitochondria in serial blockface scanning electron microscopic data. Previously developed texture based methods are limited for solving this problem because texture alone is often not sufficient to identify mitochondria. This paper presents a new three-step method, the Cytoseg process, for automated segmentation of mitochondria contained in 3D electron microscopic volumes generated through serial block face scanning electron microscopic imaging. The method consists of three steps. The first is a random forest patch classification step operating directly on 2D image patches. The second step consists of contour-pair classification. At the final step, we introduce a method to automatically seed a level set operation with output from previous steps. Results We report accuracy of the Cytoseg process on three types of tissue and compare it to a previous method based on Radon-Like Features. At step 1, we show that the patch classifier identifies mitochondria texture but creates many false positive pixels. At step 2, our contour processing step produces contours and then filters them with a second classification step, helping to improve overall accuracy. We show that our final level set operation, which is automatically seeded with output from previous steps, helps to smooth the results. Overall, our results show that use of contour pair classification and level set operations improve segmentation accuracy beyond patch classification alone. We show that the Cytoseg process performs well compared to another modern technique based on Radon-Like Features. Conclusions We demonstrated that texture based methods for mitochondria segmentation can be enhanced with multiple steps that form an image processing pipeline. While we used a random-forest based patch classifier to recognize texture, it would be possible to replace this with other texture identifiers, and we plan to explore this in future work. PMID:22321695

  10. A pleiotropy-informed Bayesian false discovery rate adapted to a shared control design finds new disease associations from GWAS summary statistics.

    PubMed

    Liley, James; Wallace, Chris

    2015-02-01

    Genome-wide association studies (GWAS) have been successful in identifying single nucleotide polymorphisms (SNPs) associated with many traits and diseases. However, at existing sample sizes, these variants explain only part of the estimated heritability. Leverage of GWAS results from related phenotypes may improve detection without the need for larger datasets. The Bayesian conditional false discovery rate (cFDR) constitutes an upper bound on the expected false discovery rate (FDR) across a set of SNPs whose p values for two diseases are both less than two disease-specific thresholds. Calculation of the cFDR requires only summary statistics and have several advantages over traditional GWAS analysis. However, existing methods require distinct control samples between studies. Here, we extend the technique to allow for some or all controls to be shared, increasing applicability. Several different SNP sets can be defined with the same cFDR value, and we show that the expected FDR across the union of these sets may exceed expected FDR in any single set. We describe a procedure to establish an upper bound for the expected FDR among the union of such sets of SNPs. We apply our technique to pairwise analysis of p values from ten autoimmune diseases with variable sharing of controls, enabling discovery of 59 SNP-disease associations which do not reach GWAS significance after genomic control in individual datasets. Most of the SNPs we highlight have previously been confirmed using replication studies or larger GWAS, a useful validation of our technique; we report eight SNP-disease associations across five diseases not previously declared. Our technique extends and strengthens the previous algorithm, and establishes robust limits on the expected FDR. This approach can improve SNP detection in GWAS, and give insight into shared aetiology between phenotypically related conditions.

  11. Recurrence of “cured” dural arteriovenous fistulas after Onyx embolization

    PubMed Central

    Adamczyk, Peter; Amar, Arun Paul; Mack, William J.; Larsen, Donald W.

    2012-01-01

    Endovascular embolization with Onyx has been increasingly used to treat intracranial and spinal dural arteriovenous fistulas (DAVFs). Several case series have been published in recent years reporting high DAVF cure rates with this technique. Although it is seldom reported, DAVF recurrence may occur despite initial “cure.” The authors present 3 separate cases of a recurrent DAVF after successful transarterial Onyx embolization. Despite adequate Onyx penetration into the fistula and draining vein, these cases demonstrate that DAVF recanalization may reappear with filling from previous or newly recruited arterial feeders. Other published reports of DAVF recurrence are examined, and potential contributory factors are discussed. These cases highlight the need for awareness of this possible phenomenon and suggest that follow-up angiography should be considered in patients treated with catheter embolization. PMID:22537121

  12. Rapid brain death caused by a cerebellar abscess with Fusobacterium nucleatum in a young man with drug abuse: a case report.

    PubMed

    Hischebeth, Gunnar T R; Keil, Vera C; Gentil, Katrin; Boström, Azize; Kuchelmeister, Klaus; Bekeredjian-Ding, Isabelle

    2014-06-10

    Fusobacterium nucleatum is a strict anaerobic microorganism that causes disease entities such as periodontal and soft tissue abscesses, pulmonary and intraabdominal infections and very rarely intracerebral infections. Here, we report the rare case of a previously healthy 25-year-old German man with a cerebellar abscess caused by Fusobacterium nucleatum that resulted in rapid brain death. Toxicological screening showed positivity for amphetamines and cannabis. The diagnosis was obtained by polymerase chain reaction amplification of bacterial deoxyribonucleic acid in cerebrospinal fluid. In drug users clinicians should think about rare causes of brain abscesses/meningitis. Early diagnosis is necessary and justifies the use of molecular techniques.

  13. Editorial Commentary: The Jury Remains Out on Hybrid Autograft-Plus-Allograft for Diminutive Hamstring Anterior Cruciate Ligament Autografts.

    PubMed

    Dhawan, Aman

    2016-11-01

    In a Level III, single center, retrospective, nonrandomized observational study, anterior cruciate ligament reconstruction revision rates and patient-reported outcomes were found to be similar at 2-year follow-up when using autograft hamstrings versus a hybrid graft (autograft and nonirradiated allograft), with both groups reporting low levels of revisions and excellent outcomes. Despite previous published data that were cause for concern, a study in this issue provides support for use of a hybrid graft technique when encountering the challenging situation of a diminutive hamstring autograft when performing anterior cruciate ligament reconstruction. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  14. Groundwater Pathway Model for the Los Alamos National Laboratory Technical Area 21, Material Disposal Area T

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stauffer, Philip H.; Levitt, Daniel G.; Miller, Terry Ann

    2017-02-09

    This report consists of four major sections, including this introductory section. Section 2 provides an overview of previous investigations related to the development of the current sitescale model. The methods and data used to develop the 3-D groundwater model and the techniques used to distill that model into a form suitable for use in the GoldSim models are discussed in Section 3. Section 4 presents the results of the model development effort and discusses some of the uncertainties involved. Three attachments that provide details about the components and data used in this groundwater pathway model are also included with thismore » report.« less

  15. A cubic extended interior penalty function for structural optimization

    NASA Technical Reports Server (NTRS)

    Prasad, B.; Haftka, R. T.

    1979-01-01

    This paper describes an optimization procedure for the minimum weight design of complex structures. The procedure is based on a new cubic extended interior penalty function (CEIPF) used with the sequence of unconstrained minimization technique (SUMT) and Newton's method. The Hessian matrix of the penalty function is approximated using only constraints and their derivatives. The CEIPF is designed to minimize the error in the approximation of the Hessian matrix, and as a result the number of structural analyses required is small and independent of the number of design variables. Three example problems are reported. The number of structural analyses is reduced by as much as 50 per cent below previously reported results.

  16. Isolation of a new dual-functional caffeine synthase gene encoding an enzyme for the conversion of 7-methylxanthine to caffeine from coffee (Coffea arabica L.).

    PubMed

    Mizuno, Kouichi; Okuda, Akira; Kato, Misako; Yoneyama, Naho; Tanaka, Hiromi; Ashihara, Hiroshi; Fujimura, Tatsuhito

    2003-01-16

    In coffee and tea plants, caffeine is synthesized from xanthosine via a pathway that includes three methylation steps. We report the isolation of a bifunctional coffee caffeine synthase (CCS1) clone from coffee endosperm by reverse transcription-polymerase chain reaction (RT-PCR) and rapid amplification of cDNA ends (RACE) technique using previously reported sequence information for theobromine synthases (CTSs). The predicted amino acid sequences of CCS1 are more than 80% identical to CTSs and are about 40% similar to those of tea caffeine synthase (TCS1). Interestingly, CCS1 has dual methylation activity like tea TCS1.

  17. Further Improvement in Outcomes of Nasopharyngeal Carcinoma With Optimized Radiotherapy and Induction Plus Concomitant Chemotherapy: An Update of the Milan Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Palazzi, Mauro; Orlandi, Ester; Bossi, Paolo

    2009-07-01

    Purpose: To report the outcome of a consecutive series of patients with nonmetastatic nasopharyngeal carcinoma (NPC), focusing on the impact of treatment-related factors. Methods and Materials: Between 2000 and 2006, 87 patients with NPC were treated with either conventional (two- or three-dimensional) radiotherapy (RT) or with intensity-modulated RT (IMRT). Of these patients, 81 (93%) received either concomitant CHT (24%) or both induction and concomitant chemotherapy (CHT) (69%). Stage was III in 36% and IV in 39% of patients. Outcomes in this study population were compared with those in the previous series of 171 patients treated during 1990 to 1999. Results:more » With a median follow-up of 46 months, actuarial rates at 3 years were the following: local control, 96%; local-regional control, 93%; distant control (DC), 90%; disease-free survival (DFS), 82%; overall survival, 90%. In Stage III to IV patients, distant control at 3 years was 56% in patients treated with concomitant CHT only and 92% in patients treated with both induction and concomitant CHT (p = 0.014). At multivariate analysis, histology, N-stage, RT technique, and total RT dose had the strongest independent impact on DFS (p < 0.05). Induction CHT had a borderline effect on DC (p = 0.07). Most dosimetric statistics were improved in the group of patients treated with IMRT compared with conventional 3D technique. All outcome endpoints were substantially better in the study population compared with those in the previous series. Conclusions: Outcome of NPC has further improved in the study period compared with the previous decade, with a significant effect of RT technique optimization. The impact of induction CHT remains to be demonstrated in controlled trials.« less

  18. The Question of Impurities in Macromolecule Crystal Quality Improvement in Microgravity

    NASA Technical Reports Server (NTRS)

    Judge, Russell A.; Snell, Edward H.; Pusey, Marc L.; Sportiello, Michael G.; Todd, Paul; Bellamy, Henry; Borgstahl, Gloria E.; Pokros, Matthew; Cassanto, John M.

    2000-01-01

    While macromolecule impurities may affect crystal size and morphology the over-riding question is how do macromolecule impurities effect crystal X-ray quality and diffraction resolution. In the case of chicken egg white lysozyme previous researchers have reported that crystals grown in the presence of ovalbumin, ovotransferrin, and turkey egg white lysozyme show no difference in diffraction resolution compared to those grown in pure solutions. One impurity however, a naturally occurring lysozyme dimer, does negatively impact the X-ray crystal properties. For this impurity it has been reported that crystal quality improvement in microgravity may be due to improved impurity partitioning during crystallization. In this study we have examined the incorporation of the dimer into lysozyme crystals, both on the ground and in microgravity experiments, and have performed detailed X-ray analysis of the crystals using a new technique for finely probing the mosaicity of the crystal at the Stanford Synchrotron Radiation Laboratory. Dimer partitioning was not significantly different in microgravity compared to the ground based experiments, although it is significantly better than that previously reported in microgravity. Mosaicity analysis of pure crystals, 1422 indexed reflections (microgravity) and 752 indexed reflections (ground), gave average results of 0.0066 and 0.0092 degrees (FWHM) respectively. The microgravity crystals also provided an increased signal to noise. Dimer incorporation increased the average mosaicity in microgravity but not on the ground. However, dimer incorporation did greatly reduce the resolution limit in both ground and microgravity grown crystals. The data is being treated anisotropically to explore these effects. These results indicate that impurity effects in microgravity are complex and that the conditions or techniques employed may greatly affect the role of impurities.

  19. New techniques for positron emission tomography in the study of human neurological disorders: Progress report, 15 June 1992--31 October 1992

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-01-01

    During the past six months, we have continued work on the fronts of kinetic modeling of radioligands for studying neurotransmitter/receptor systems, iterative reconstruction techniques, and methodology for PET cerebral blood flow activation studies. Initial human PET studies have been performed and analyzed with many different kinetic model formulations to determine the quantitative potential of the neuronwsmitter/receptor ligand, ({sup 11}C)N-methyl piperidyl benzilate (NMPB), a muscarinic cholinergic antagonist. In addition, initial human studies using ({sup 11}C)tetrabenazine (TBZ), a marker for monoantine nerve terminal density. Results of the NWB studies have indicated that this new agent yields better estimates of receptor density thanmore » previous muscarinic ligands developed at our facility, ({sup 11}C)-TRB and ({sup 11}C)scopolamine. TRB and scopolamine have previously been shown to be only partially successful ligands due to sub-optimal values of the individual rate constants, causing varying degrees of flow limitation. This is found to be much less of a problem for NMPB due to the 2.0--2.5 fold increase in ligand transport observed in the human studies ({approximately}60% first pass extraction). A 2-parameter 2-compartment simplification had previously been implemented for the benzodiazepine ligand, (C-11)FMZ, and a similar model appears to be suitable for TBZ based on the preliminary human data.« less

  20. New techniques for positron emission tomography in the study of human neurological disorders: Progress report, 15 June 1992--31 October 1992

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-10-01

    During the past six months, we have continued work on the fronts of kinetic modeling of radioligands for studying neurotransmitter/receptor systems, iterative reconstruction techniques, and methodology for PET cerebral blood flow activation studies. Initial human PET studies have been performed and analyzed with many different kinetic model formulations to determine the quantitative potential of the neuronwsmitter/receptor ligand, [{sup 11}C]N-methyl piperidyl benzilate (NMPB), a muscarinic cholinergic antagonist. In addition, initial human studies using [{sup 11}C]tetrabenazine (TBZ), a marker for monoantine nerve terminal density. Results of the NWB studies have indicated that this new agent yields better estimates of receptor density thanmore » previous muscarinic ligands developed at our facility, [{sup 11}C]-TRB and [{sup 11}C]scopolamine. TRB and scopolamine have previously been shown to be only partially successful ligands due to sub-optimal values of the individual rate constants, causing varying degrees of flow limitation. This is found to be much less of a problem for NMPB due to the 2.0--2.5 fold increase in ligand transport observed in the human studies ({approximately}60% first pass extraction). A 2-parameter 2-compartment simplification had previously been implemented for the benzodiazepine ligand, [C-11]FMZ, and a similar model appears to be suitable for TBZ based on the preliminary human data.« less

  1. A Survey of Injuries Affecting Pre-Professional Ballet Dancers.

    PubMed

    Caine, Dennis; Bergeron, Glen; Goodwin, Brett J; Thomas, Jessica; Caine, Caroline G; Steinfeld, Sam; Dyck, Kevin; André, Suzanne

    2016-01-01

    A cross-sectional design was employed retrospectively to evaluate injuries self-reported by 71 pre-professional ballet dancers over one season. Some of the descriptive findings of this survey were consistent with those of previous research and suggest particular demographic and injury trends in pre-professional ballet. These results include gender distribution, mean age and age range of participants, training hours, injury location, acute versus overuse injuries, as well as average number of physiotherapy treatments per dancer. Other results provide information that was heretofore unreported or inconsistent with previous investigations. These findings involved proportion of dancers injured, average number of injuries per dancer, overall injury incidence during an 8.5 month period, incidence rate by technique level, mean time loss per injury, proportion of recurrent injury, and activity practiced at time of injury. The results of univariate analyses revealed several significant findings, including a decrease in incidence rate of injury with increased months of experience in the pre-professional program, dancers having lower injury risk in rehearsal and performance than in class, and a reduced risk of injury for dancers at certain technique levels. However, only this latter finding remained significant in multivariate analysis. The results of this study underscore the importance of determining injury rates by gender, technique level, and activity setting in addition to overall injury rates. They also point to the necessity of looking at both overall and individual dancer-based injury risks.

  2. Photorefractive keratectomy at 193 nm using an erodible mask

    NASA Astrophysics Data System (ADS)

    Gordon, Michael; Brint, Stephen F.; Durrie, Daniel S.; Seiler, Theo; Friedman, Marc D.; Johnsson, N. M. F.; King, Michael C.; Muller, David F.

    1992-08-01

    Clinical experience with more than ten thousand sighted eyes has demonstrated great promise for correcting myopia with photorefractive keratectomy (PRK). Previously reported techniques have incorporated computer-controlled irises, diaphragms, and apertures to regulate the desired distribution of 193 nm radiation onto the eye. This paper reports on an entirely new approach for performing PRK which utilizes an erodible mask to control the shape transfer process. Compared to the more traditional techniques, the erodible mask offers promise of correcting a broad range of refractive errors. In this paper the erodible mask and associated hardware are described in detail. We describe the shape transfer experiments used to predict the functional relationship between the desired refractive correction and the mask shape. We report on early clinical results from five patients with myopic astigmatism. We conclude that the early shape transfer experiments overestimated the spherical component of the correction by 1.25 diopters and underestimated the cylindrical component by approximately 0.85 diopters. The data suggest there may be biological effects which evoke different healing responses when myopic PRK corrections are performed with and without astigmatism. Clinical trials are proceeding with the mask shapes adjusted for these observations.

  3. High resolution near on-axis digital holography using constrained optimization approach with faster convergence

    NASA Astrophysics Data System (ADS)

    Pandiyan, Vimal Prabhu; Khare, Kedar; John, Renu

    2017-09-01

    A constrained optimization approach with faster convergence is proposed to recover the complex object field from a near on-axis digital holography (DH). We subtract the DC from the hologram after recording the object beam and reference beam intensities separately. The DC-subtracted hologram is used to recover the complex object information using a constrained optimization approach with faster convergence. The recovered complex object field is back propagated to the image plane using the Fresnel back-propagation method. The results reported in this approach provide high-resolution images compared with the conventional Fourier filtering approach and is 25% faster than the previously reported constrained optimization approach due to the subtraction of two DC terms in the cost function. We report this approach in DH and digital holographic microscopy using the U.S. Air Force resolution target as the object to retrieve the high-resolution image without DC and twin image interference. We also demonstrate the high potential of this technique in transparent microelectrode patterned on indium tin oxide-coated glass, by reconstructing a high-resolution quantitative phase microscope image. We also demonstrate this technique by imaging yeast cells.

  4. Prosthetic valve sparing aortic root replacement: an improved technique.

    PubMed

    Leacche, Marzia; Balaguer, Jorge M; Umakanthan, Ramanan; Byrne, John G

    2008-10-01

    We describe a modified surgical technique to treat patients with a previous history of isolated aortic valve replacement who now require aortic root replacement for an aneurysmal or dissected aorta. This technique consists of replacing the aortic root with a Dacron conduit, leaving intact the previously implanted prosthesis, and re-implanting the coronary arteries in the Dacron graft. Our technique differs from other techniques in that we do not leave behind any aortic tissue remnant and also in that we use a felt strip to obliterate any gap between the old sewing ring and the newly implanted graft. In our opinion, this promotes better hemostasis. We demonstrate that this technique is safe, feasible, and results in acceptable outcomes.

  5. Radiographic Measurement of Displacement in Acetabular Fractures: A Systematic Review of the Literature.

    PubMed

    Dodd, Andrew; Osterhoff, Georg; Guy, Pierre; Lefaivre, Kelly A

    2016-06-01

    To report methods of measurement of radiographic displacement and radiographic outcomes in acetabular fractures described in the literature. A systematic review of the English literature was performed using EMBASE and Medline in August 2014. Inclusion criteria were studies of operatively treated acetabular fractures in adults with acute (<6 weeks) open reduction and internal fixation that reported radiographic outcomes. Exclusion criteria included case series with <10 patients, fractures managed >6 weeks from injury, acute total hip arthroplasty, periprosthetic fractures, time frame of radiographic outcomes not stated, missing radiographic outcome data, and non-English language articles. Basic information collected included journal, author, year published, number of fractures, and fracture types. Specific data collected included radiographic outcome data, method of measuring radiographic displacement, and methods of interpreting or categorizing radiographic outcomes. The number of reproducible radiographic measurement techniques (2/64) and previously described radiographic interpretation methods (4) were recorded. One radiographic reduction grading criterion (Matta) was used nearly universally in articles that used previously described criteria. Overall, 70% of articles using this criteria documented anatomic reductions. The current standard of measuring radiographic displacement in publications dealing with acetabulum fractures almost universally lacks basic description, making further scientific rigor, such as testing reproducibility, impossible. Further work is necessary to standardize radiographic measurement techniques, test their reproducibility, and qualify their validity or determine which measurements are important to clinical outcomes. Diagnostic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  6. Amino acid distribution in meteorites: diagenesis, extraction methods, and standard metrics in the search for extraterrestrial biosignatures.

    PubMed

    McDonald, Gene D; Storrie-Lombardi, Michael C

    2006-02-01

    The relative abundance of the protein amino acids has been previously investigated as a potential marker for biogenicity in meteoritic samples. However, these investigations were executed without a quantitative metric to evaluate distribution variations, and they did not account for the possibility of interdisciplinary systematic error arising from inter-laboratory differences in extraction and detection techniques. Principal component analysis (PCA), hierarchical cluster analysis (HCA), and stochastic probabilistic artificial neural networks (ANNs) were used to compare the distributions for nine protein amino acids previously reported for the Murchison carbonaceous chondrite, Mars meteorites (ALH84001, Nakhla, and EETA79001), prebiotic synthesis experiments, and terrestrial biota and sediments. These techniques allowed us (1) to identify a shift in terrestrial amino acid distributions secondary to diagenesis; (2) to detect differences in terrestrial distributions that may be systematic differences between extraction and analysis techniques in biological and geological laboratories; and (3) to determine that distributions in meteoritic samples appear more similar to prebiotic chemistry samples than they do to the terrestrial unaltered or diagenetic samples. Both diagenesis and putative interdisciplinary differences in analysis complicate interpretation of meteoritic amino acid distributions. We propose that the analysis of future samples from such diverse sources as meteoritic influx, sample return missions, and in situ exploration of Mars would be less ambiguous with adoption of standardized assay techniques, systematic inclusion of assay standards, and the use of a quantitative, probabilistic metric. We present here one such metric determined by sequential feature extraction and normalization (PCA), information-driven automated exploration of classification possibilities (HCA), and prediction of classification accuracy (ANNs).

  7. Low-flow frequency and flow duration of selected South Carolina streams in the Broad River basin through March 2008

    USGS Publications Warehouse

    Guimaraes, Wladmir B.; Feaster, Toby D.

    2010-01-01

    Of the 23 streamgaging stations for which recurrence interval computations were made, 14 had low-flow statistics that were published in previous U.S. Geological Survey reports. A comparison of the low-flow statistics for the minimum mean flow for a 7-consecutive-day period with a 10-year recurrence interval (7Q10) from this study with the most recently published values indicated that 8 of the 14 streamgaging stations had values that were within plus or minus 25 percent of the previous value. Ten of the 14 streamgaging stations had negative percent differences indicating the low-flow statistic had decreased since the previous study, and 4 streamgaging stations had positive percent differences indicating that the low-flow statistic had increased since the previous study. The low-flow statistics are influenced by length of record, hydrologic regime under which the record was collected, techniques used to do the analysis, and other changes, such as urbanization, diversions, and so on, that may have occurred in the basin.

  8. Limits of the copper decoration technique for delineating of the V I boundary

    NASA Astrophysics Data System (ADS)

    Válek, L.; Stehlík, Š.; Orava, J.; Ďurík, M.; Šik, J.; Wágner, T.

    2007-05-01

    Copper decoration technique was used for detection of the vacancy interstitial (V I) boundary in Czochralski silicon crystal. We used the technique for delineating defects in silicon previously reported by Mule’Stagno [Solid State Phenom. 82 84 (2002) 753] and we enriched it by an upgraded application of copper on the silicon surface. The new procedure is based on the deposition of elementary copper on the silicon surface from the copper nitrate solution. The new method is more efficient contrary to Mule’Stagno (2002) and it also decreases environmental drain. We compared five etchants in order to optimize the delineation of the V I boundary. A defect region of the same diameter was detected by all the used etchants, supreme sensitivity was obtained with Wright's etchant. The outer diameter of the defect region observed by the copper decoration technique coincides with the V I boundary diameter measured by OISF testing and approximately coincides with the V I boundary diameter measured by COP testing. We found that the copper decoration technique delineates oxygen precipitates in silicon and we observed the dependence of V I boundary detectability on the size of the oxygen precipitates.

  9. Breech repositioning unresponsive to Webster technique: coexistence of oligohydramnios

    PubMed Central

    Roecker, Christopher B.

    2013-01-01

    Objective The purpose of this report is to describe the results of a pregnant woman demonstrating breech fetal presentation who was managed with Webster technique in the presence of oligohydramnios. Clinical Features A 23-year-old primigravida woman sought chiropractic care for the management of breech presentation and bilateral sacroiliac arthralgia at 34 weeks’ gestation. Intervention and Outcome Sacral manipulation and abdominal effleurage (Webster Technique) was used to address breech presentation and sacroiliac arthralgia for a total of 7 treatments over a 3 1/2-week duration. The patient’s sacroiliac pain reduced from 8/10 to 3/10. However, breech presentation was unchanged at each treatment. At a scheduled prenatal surveillance during the 37th week of gestation, the midwife detected vaginal bleeding and reduced fundal height, which resulted in hospitalization, diagnosis of oligohydramnios, and an emergency cesarean delivery. Conclusion For this particular patient, the breech presentation was not corrected using the Webster technique. Clinicians who use the Webster technique to manage breech fetal presentation should be aware of undiagnosed comorbidities as a complicating factor in clinical presentation. Screening for previously undiagnosed comorbidities, such as oligohydramnios, must be considered. PMID:24294149

  10. Damage identification in beams using speckle shearography and an optimal spatial sampling

    NASA Astrophysics Data System (ADS)

    Mininni, M.; Gabriele, S.; Lopes, H.; Araújo dos Santos, J. V.

    2016-10-01

    Over the years, the derivatives of modal displacement and rotation fields have been used to localize damage in beams. Usually, the derivatives are computed by applying finite differences. The finite differences propagate and amplify the errors that exist in real measurements, and thus, it is necessary to minimize this problem in order to get reliable damage localizations. A way to decrease the propagation and amplification of the errors is to select an optimal spatial sampling. This paper presents a technique where an optimal spatial sampling of modal rotation fields is computed and used to obtain the modal curvatures. Experimental measurements of modal rotation fields of a beam with single and multiple damages are obtained with shearography, which is an optical technique allowing the measurement of full-fields. These measurements are used to test the validity of the optimal sampling technique for the improvement of damage localization in real structures. An investigation on the ability of a model updating technique to quantify the damage is also reported. The model updating technique is defined by the variations of measured natural frequencies and measured modal rotations and aims at calibrating the values of the second moment of area in the damaged areas, which were previously localized.

  11. Canine transurethral laser prostatectomy using a rotational technique

    NASA Astrophysics Data System (ADS)

    Cromeens, Douglas M.; Johnson, Douglas E.

    1995-05-01

    Conventional radical prostatectomy in the dog has historically been attended by unacceptably high incidence of urinary incontinence (80 - 100%). Ablation of the prostate can be accomplished in the dog by transurethral irradiation of the prostate with the Nd:YAG laser and a laterally deflecting fiber. Exposure has ranged between 40 and 60 watts for 60 seconds at 4 fixed locations. Although prostatectomies performed with the above described technique offers significant advantage over conventional prostatectomies, the high power density at each location can result in small submucosal explosions (`popcorn effect') that increase the potential for bleeding and rupture of the prostatic capsule. We describe a new technique in which the energy is applied continuously by a laser fiber rotating around a central point. Delivering 40 watts of Nd:YAG energy for 4 minutes using a new angle-delivery device (UrotekTM), we produced results comparable to those of other previously reported techniques in the canine model with two added advantages: (1) a more even application of heat resulting in no `popcorn' effect and (2) a more reliably predictable area of coagulative necrosis within a given axial plane. This technique should provide additional safety for the veterinary surgeon performing visual laser ablation of the prostate in the dog.

  12. App-assisted external ventricular drain insertion.

    PubMed

    Eftekhar, Behzad

    2016-09-01

    The freehand technique for insertion of an external ventricular drain (EVD) is based on fixed anatomical landmarks and does not take individual variations into consideration. A patient-tailored approach based on augmented-reality techniques using devices such as smartphones can address this shortcoming. The Sina neurosurgical assist (Sina) is an Android mobile device application (app) that was designed and developed to be used as a simple intraoperative neurosurgical planning aid. It overlaps the patient's images from previously performed CT or MRI studies on the image seen through the device camera. The device is held by an assistant who aligns the images and provides information about the relative position of the target and EVD to the surgeon who is performing EVD insertion. This app can be used to provide guidance and continuous monitoring during EVD placement. The author describes the technique of Sina-assisted EVD insertion into the frontal horn of the lateral ventricle and reports on its clinical application in 5 cases as well as the results of ex vivo studies of ease of use and precision. The technique has potential for further development and use with other augmented-reality devices.

  13. Prediction of quantitative intrathoracic fluid volume to diagnose pulmonary oedema using LabVIEW.

    PubMed

    Urooj, Shabana; Khan, M; Ansari, A Q; Lay-Ekuakille, Aimé; Salhan, Ashok K

    2012-01-01

    Pulmonary oedema is a life-threatening disease that requires special attention in the area of research and clinical diagnosis. Computer-based techniques are rarely used to quantify the intrathoracic fluid volume (IFV) for diagnostic purposes. This paper discusses a software program developed to detect and diagnose pulmonary oedema using LabVIEW. The software runs on anthropometric dimensions and physiological parameters, mainly transthoracic electrical impedance (TEI). This technique is accurate and faster than existing manual techniques. The LabVIEW software was used to compute the parameters required to quantify IFV. An equation relating per cent control and IFV was obtained. The results of predicted TEI and measured TEI were compared with previously reported data to validate the developed program. It was found that the predicted values of TEI obtained from the computer-based technique were much closer to the measured values of TEI. Six new subjects were enrolled to measure and predict transthoracic impedance and hence to quantify IFV. A similar difference was also observed in the measured and predicted values of TEI for the new subjects.

  14. Microfabricated FSCV-Compatible Microelectrode Array for Real-time Monitoring of Heterogeneous Dopamine Release

    PubMed Central

    Zachek, Matthew K.; Park, Jinwoo; Takmakov, Pavel; Wightman, R. Mark; McCarty, Gregory S.

    2010-01-01

    Fast scan cyclic voltammetry (FSCV) has been used previously to detect neurotransmitter release and reuptake in vivo. An advantage that FSCV has over other electrochemical techniques is its ability to distinguish neurotransmitters of interest (i.e. monoamines) from their metabolites using their respective characteristic cyclic voltammogram. While much has been learned with this technique, it has generally only been used in a single working electrode arrangement. Additionally, traditional electrode fabrication techniques tend to be difficult and somewhat irreproducible. Described in this report is a fabrication method for a FSCV compatible microelectrode array (FSCV-MEA) that is capable of functioning in vivo. The microfabrication techniques employed here allow for better reproducibility than traditional fabrication methods of carbon fiber microelectrodes, and enable batch fabrication of electrode arrays. The reproducibility and electrochemical qualities of the probes were assessed along with cross talk in vitro. Heterogeneous release of electrically stimulated dopamine was observed in real-time in the striatum of an anesthetized rat using the FSCV-MEA. The heterogeneous effects of pharmacology on the striatum was also observed and shown to be consistent across multiple animals. PMID:20464031

  15. Increased Oil Production and Reserves from Improved Completion Techniques in the Bluebell Field, Uinta Basin, Utah

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deo, M.D.; Morgan, C.D.

    1999-04-28

    The objective of the project is to increase oil production and reserves by the use of improved reservoir characterization and completion techniques in the Uinta Basin, Utah. To accomplish this objective, a two-year geologic and engineering characterization of the Bluebell field was conducted. The study evaluated surface and subsurface data, currently used completion techniques, and common production problems. It was determined that advanced case- and open-hole logs could be effective in determining productive beds and that stage-interval (about 500 ft [150 m] per stage) and bed-scale isolation completion techniques could result in improved well performance. In the first demonstration wellmore » (Michelle Ute well discussed in the previous technical report), dipole shear anisotropy (anisotropy) and dual-burst thermal decay time (TDT) logs were run before and isotope tracer log was run after the treatment. The logs were very helpful in characterizing the remaining hydrocarbon potential in the well. But, mechanical failure resulted in a poor recompletion and did not result in a significant improvement in the oil production from the well.« less

  16. Ant colony optimisation-direct cover: a hybrid ant colony direct cover technique for multi-level synthesis of multiple-valued logic functions

    NASA Astrophysics Data System (ADS)

    Abd-El-Barr, Mostafa

    2010-12-01

    The use of non-binary (multiple-valued) logic in the synthesis of digital systems can lead to savings in chip area. Advances in very large scale integration (VLSI) technology have enabled the successful implementation of multiple-valued logic (MVL) circuits. A number of heuristic algorithms for the synthesis of (near) minimal sum-of products (two-level) realisation of MVL functions have been reported in the literature. The direct cover (DC) technique is one such algorithm. The ant colony optimisation (ACO) algorithm is a meta-heuristic that uses constructive greediness to explore a large solution space in finding (near) optimal solutions. The ACO algorithm mimics the ant's behaviour in the real world in using the shortest path to reach food sources. We have previously introduced an ACO-based heuristic for the synthesis of two-level MVL functions. In this article, we introduce the ACO-DC hybrid technique for the synthesis of multi-level MVL functions. The basic idea is to use an ant to decompose a given MVL function into a number of levels and then synthesise each sub-function using a DC-based technique. The results obtained using the proposed approach are compared to those obtained using existing techniques reported in the literature. A benchmark set consisting of 50,000 randomly generated 2-variable 4-valued functions is used in the comparison. The results obtained using the proposed ACO-DC technique are shown to produce efficient realisation in terms of the average number of gates (as a measure of chip area) needed for the synthesis of a given MVL function.

  17. Massive Pulmonary Calculi Embolism: A Novel Complication of Pneumatic Lithotripsy: A Case Report.

    PubMed

    Zhang, Lin; Zhou, Yiwu

    2015-07-01

    Pneumatic lithotripsy is a minimally invasive technique mainly for the treatment of urinary staghorn stones. Previous literatures have reported some therapeutic complications during or after this procedure, but calculi embolism has not been mentioned before.We report here a fatal case of calculi-induced pulmonary embolism in an adult woman who underwent pneumatic lithotripsy. An autopsy did not reveal any evidence of pulmonary embolism. However, light microscopy revealed noticeable presence of calculi in pulmonary arterioles and capillaries, as evidenced by environmental scanning electron microscope and energy dispersive X-ray analysis. The primary determinants of calculi embolism include intrarenal pressure, and volume and viscosity of the calculi fragments formation. Vascular intravasation of smashed calculi might increase pulmonary vascular resistance and hypoxemia and decrease cardiac output.This case report intends to provide information for clinicians to consider the probability of intraoperative calculi embolism during lithotripsies when patients develop typical symptoms of acute pulmonary embolism.

  18. Thrust imbalance of solid rocket motor pairs on Space Shuttle flights

    NASA Technical Reports Server (NTRS)

    Foster, W. A., Jr.; Shu, P. H.; Sforzini, R. H.

    1986-01-01

    This analysis extends the investigation presented at the 17th Joint Propulsion Conference in 1981 to include fifteen sets of Space Shuttle flight data. The previous report dealt only with static test data and the first flight pair. The objective is to compare the authors' previous theoretical analysis of thrust imbalance with actual Space Shuttle performance. The theoretical prediction method, which involves a Monte Carlo technique, is reviewed briefly as are salient features of the flight instrumentation system and the statistical analysis. A scheme for smoothing flight data is discussed. The effects of changes in design parameters are discussed with special emphasis on the filament wound motor case being developed to replace the steel case. Good agreement between the predictions and the flight data is demonstrated.

  19. The missed inferior alveolar block: a new look at an old problem.

    PubMed

    Milles, M

    1984-01-01

    A variation of a previously described technique to obtain mandibular block anesthesia is presented. This technique varies from those previously described in that is uses palpable anatomic landmarks, both extra- and intraoral, to orient the placement of the needle. This technique relies on several readily observed landmarks and the integration of these landmarks. Because palpable landmarks are used, consistent results can be easily obtained even in patients who present with a wide variety of anatomical variances which otherwise make this injection technique difficult and prone to failure.

  20. Three-Dimensional Printing: An Aid to Epidural Access for Neuromodulation.

    PubMed

    Taverner, Murray G; Monagle, John P

    2017-08-01

    The case report details to use of three-dimensional (3D) printing as an aid to neuromodulation. A patient is described in whom previous attempts at spinal neuromodulation had failed due to lack of epidural or intrathecal access, and the use of a 3D printed model allowed for improved planning and ultimately, success. Successful spinal cord stimulation was achieved with the plan developed by access to a 3D model of the patient's spine. Neuromodulation techniques can provide the optimal analgesic techniques for individual patients. At times these can fail due to lack of access to the site for intervention, in this case epidural access. 3D printing may provide additional information to improve the likelihood of access when anatomy is distorted and standard approaches prove difficult. © 2017 International Neuromodulation Society.

  1. Corrosion, stress corrosion cracking, and electrochemistry of the iron and nickel base alloys in caustic environments. Progress report, 1 March 1977--28 February 1978

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Staehle, R.W.; Agrawal, A.K.

    1978-01-01

    The straining electrode technique was used to evaluate the stress corrosion cracking (SCC) susceptibility of AISI 304 stainless steel in 20N NaOH solution, and of Inconel 600 Alloy and Incoloy 800 Alloy in boiling 17.5N NaOH solution. The crack propagation rate estimated from the straining experiments correlated well with the previous constant load experiments. It was found that the straining electrode technique is a useful method for estimating, through short term experiments, parameters like crack propagation rate, crack morphology, and repassivation rate, as a function of the electrode potential. The role of alloying elements on the crack propagation rate inmore » the above alloys are also discussed.« less

  2. A data reduction technique and associated computer program for obtaining vehicle attitudes with a single onboard camera

    NASA Technical Reports Server (NTRS)

    Bendura, R. J.; Renfroe, P. G.

    1974-01-01

    A detailed discussion of the application of a previously method to determine vehicle flight attitude using a single camera onboard the vehicle is presented with emphasis on the digital computer program format and data reduction techniques. Application requirements include film and earth-related coordinates of at least two landmarks (or features), location of the flight vehicle with respect to the earth, and camera characteristics. Included in this report are a detailed discussion of the program input and output format, a computer program listing, a discussion of modifications made to the initial method, a step-by-step basic data reduction procedure, and several example applications. The computer program is written in FORTRAN 4 language for the Control Data 6000 series digital computer.

  3. A multiplanar complex resection of a low-grade chondrosarcoma of the distal femur guided by K-wires previously inserted under CT-guide: a case report

    PubMed Central

    2014-01-01

    Background In muscular skeletal oncology aiming to achieve wide surgical margin is one of the main factors influencing patient prognosis. In cases where lesions are either meta or epiphyseal, surgery most often compromises joint integrity and stability because muscles, tendons and ligaments are involved in wide resection. When lesions are well circumscribed they can be completely resected by performing multi-planar osteotomies guided by computer-assisted navigation. We describe a case of low-grade chondrosarcoma of the distal femur where a simple but effective technique was useful to perform complex multiplanar osteotomies. No similar techniques are reported in the literature. Case presentation A 57 year-old Caucasian female was referred to our department for the presence of a distal femur chondrosarcoma. A resection with the presenting technique was scheduled. The first step consists of inserting several K-wires under CT-scan control to delimitate the tumor; the second step consists of tumor removal: in operative theatre, following surgical access, k-wires are used as guide positioning; scalpels are externally placed to k-wires to perform a safe osteotomy. Conclusions Computed assisted resections can be considered the most advantageous method to reach the best surgical outcome; unfortunately navigation systems are only available in specialized centres. The present technique allows for a multiplanar complex resection when navigation systems are not available. This technique can be applied in low-grade tumours where a minimal wide margin can be considered sufficient. PMID:25123066

  4. Pharmacokinetics of Doxorubicin in Pregnant Women

    PubMed Central

    Ryu, Rachel J.; Eyal, Sara; Kaplan, Henry G.; Akbarzadeh, Arezoo; Hays, Karen; Puhl, Kristin; Easterling, Thomas R.; Berg, Stacey L.; Scorsone, Kathleen A.; Feldman, Eric M.; Umans, Jason G.; Miodovnik, Menachem; Hebert, Mary F.

    2014-01-01

    Purpose Our objective was to evaluate the pharmacokinetics (PK) of doxorubicin during pregnancy compared to previously published data from non-pregnant subjects. Methods During mid- to late-pregnancy, serial blood and urine samples were collected over 72 hours from 7 women treated with doxorubicin for malignancies. PK parameters were estimated using noncompartmental techniques. Pregnancy parameters were compared to those previously reported non-pregnant subjects. Results During pregnancy, mean (± SD) doxorubicin PK parameters utilizing 72 hour sampling were: clearance (CL), 412 ± 80 mL/min/m2; steady-state volume of distribution (Vss), 1132 ± 476 L/m2; and terminal half-life (T1/2), 40.3 ± 8.9 hr. The BSA-adjusted CL was significantly decreased (p < 0.01) and T1/2 was not different compared to non-pregnant women. Truncating our data to 48 hours, PK parameters were: CL, 499 ± 116 ml/min/m2; Vss, 843 ± 391 L/m2; and T1/2, 24.8 ± 5.9 hr. The BSA-adjusted CL in pregnancy compared to non-pregnant data was significantly decreased in 2 of 3 non-pregnant studies (p < 0.05, < 0.05, NS). Vss and T1/2 were not significantly different. Conclusions In pregnant subjects, we observed significantly lower doxorubicin CL in our 72 hour and most of our 48 hour sampling comparisons with previously reported non-pregnant subjects. However, the parameters were within the range previously reported in smaller studies. At this time, we cannot recommend alternate dosage strategies for pregnant women. Further research is needed to understand the mechanism of doxorubicin pharmacokinetic changes during pregnancy and optimize care for pregnant women. PMID:24531558

  5. Microsurgical techniques of anastomosis of the fallopian tubes.

    PubMed

    Smith, R N; Minkler, D

    1978-01-01

    Microsurgical techniques of anastomosis of the fallopian tubes have been studied. This paper considers the present state of the art of sterilization reversal, the training and equipment required, the potential for the diffusion of knowledge concerning reversal techniques, and the implication of current research in reversibility of sterilization for the practicing gynecologist. A preoperative study should be done on any candidate for a procedure to restore patency to the fallopian tubes to rule out other possible causes of infertility. Also, preoperative counseling should include both partners. The operating microscope offers a great advantage in the repair of several types of tubal obstruction. Midsegment end-to-end anastomosis is carried out by 1st injecting a dye into the cavity to locate the area of obstruction. The area is excised using microdissection and the fallopian tube checked for patency with the dye solution. Anastomosis is accomplished by opposing the miscularis of the tube, avoiding the mucosa. 4 sutures are usually adequate for closure. Most feel that postoperative hydrotubation is of some value in monitoring tubal patency. An organized training program in a microsurgical laboratory is the prefered way for learning the techniques. Long-term results of the microsurgical techniques for tubal anastomosis are encouraging and represent an improvement over macroscopic techniques previously reported.

  6. Long-term outcomes of the current remote magnetic catheter navigation technique for ablation of atrial fibrillation.

    PubMed

    Yuan, Shiwen; Holmqvist, Fredrik; Kongstad, Ole; Jensen, Steen M; Wang, Lingwei; Ljungström, Erik; Hertervig, Eva; Borgquist, Rasmus

    2017-12-01

    Comparisons between remote magnetic (RMN) and manual catheter navigation for atrial fibrillation (AF) ablation have earlier been reported with controversial results. However, these reports were based on earlier generations of the RMN system. To evaluate the outcomes of the most current RMN system for AF ablation in a larger patient population with longer follow-up time, 112 patients with AF (78 paroxysmal, 34 persistent) who underwent AF ablation utilizing RMN (RMN group) were compared to 102 AF ablation patients (72 paroxysmal, 30 persistent) utilizing manual technique (Manual group). The RMN group was associated with significantly shorter fluoroscopy time (10.4 ± 6.4 vs. 16.3 ± 10.9 min, p < .001) but used more RF energy (64.1 ± 19.4KJ vs. 54.3 ± 24.1 KJ, p < .05), while total procedure time showed no significant difference (201 ± 35 vs. 196 ± 44 min, NS). After 39 ± 9/44 ± 10 months of follow-up, AF-free rates at 1year, 2 years and 3.5 years post ablation were 63%, 46% and 42% in the RMN group vs. 60%, 32% and 30% (survival analysis p < .05) in the Manual group, whereas clinically effective rates were 82%, 73% and 70% for the former vs. 70%, 56% and 49% for the latter (survival analysis p < .005). Differing from previous reports, our data from a larger patient population and longer follow-up time demonstrates that compared to manual technique, the most current RMN technique is associated with better procedural and clinical outcomes for AF ablation.

  7. Laser microdissection and capture of pure cardiomyocytes and fibroblasts from infarcted heart regions: perceived hyperoxia induces p21 in peri-infarct myocytes.

    PubMed

    Kuhn, Donald E; Roy, Sashwati; Radtke, Jared; Khanna, Savita; Sen, Chandan K

    2007-03-01

    Myocardial infarction caused by ischemia-reperfusion in the coronary vasculature is a focal event characterized by an infarct-core, bordering peri-infarct zone and remote noninfarct zone. Recently, we have reported the first technique, based on laser microdissection pressure catapulting (LMPC), enabling the dissection of infarction-induced biological responses in multicellular regions of the heart. Molecular mechanisms in play at the peri-infarct zone are central to myocardial healing. At the infarct site, myocytes are more sensitive to insult than robust fibroblasts. Understanding of cell-specific responses in the said zones is therefore critical. In this work, we describe the first technique to collect the myocardial tissue with a single-cell resolution. The infarcted myocardium was identified by using a truncated hematoxylin-eosin stain. Cell elements from the infarct, peri-infarct, and noninfarct zones were collected in a chaotropic RNA lysis solution with micron-level surgical precision. Isolated RNA was analyzed for quality by employing microfluidics technology and reverse transcribed to generate cDNA. Purity of the collected specimen was established by real-time PCR analyses of cell-specific genes. Previously, we have reported that the oxygen-sensitive induction of p21/Cip1/Waf1/Sdi1 in cardiac fibroblasts in the peri-infarct zone plays a vital role in myocardial remodeling. Using the novel LMPC technique developed herein, we confirmed that finding and report for the first time that the induction of p21 in the peri-infarct zone is not limited to fibroblasts but is also evident in myocytes. This work presents the first account of an analytical technique that applies the LMPC technology to study myocardial remodeling with a cell-type specific resolution.

  8. The aetiology of paediatric inflammatory vulvovaginitis.

    PubMed

    Cuadros, Juan; Mazón, Ana; Martinez, Rocío; González, Pilar; Gil-Setas, Alberto; Flores, Uxua; Orden, Beatriz; Gómez-Herruz, Peña; Millan, Rosario

    2004-02-01

    Vulvovaginitis is the most common gynaecological problem in prepubertal girls and clear-cut data on the microbial aetiology of moderate to severe infections are lacking. Many microorganisms have been reported in several studies, but frequently the paediatrician does not know the pathogenic significance of an isolate reported in vaginal specimens of girls with vulvovaginitis. A multicentre study was performed, selecting 74 girls aged 2 to 12 years old with a clinical picture of vulvovaginitis and inflammatory cells on Gram stain. All the specimens were cultured following standard microbiological techniques and the paediatricians completed a questionnaire to highlight risk factors after interviewing the parents or tutors. The data were compared with those obtained in a control group of 11 girls without vulvovaginitis attending a clinic. Streptococcus pyogenesand Haemophilus spp.were isolated in 47 and 12 cases, respectively. Upper respiratory infection in the previous month ( P<0.001) and vulvovaginitis in the previous year ( P<0.05) were identified as significant risk factors. Foreign bodies, sexual abuse, poor hygiene and bad socioeconomic situation were not identified as risk factors for the infection. Paediatric inflammatory vulvovaginitis is mainly caused by pathogens of the upper respiratory tract and the most common risk factor for this infection is to have suffered an upper respiratory tract infection in the previous month.

  9. Radiofrequency denervation of the hip joint for pain management: case report and literature review.

    PubMed

    Gupta, Gaurav; Radhakrishna, Mohan; Etheridge, Paul; Besemann, Markus; Finlayson, Robert J

    2014-01-01

    A 55-year-old male presented with severe pain and functional limitations as a result of left hip osteoarthritis. He had failed multiple treatments while waiting for a hip arthroplasty, including physical therapy, medications, and various intra-articular injections. Thermal radiofrequency lesioning of the obturator and femoral articular branches to the hip joint was offered in the interim. To our knowledge, this is the first report to describe an inferior-lateral approach for lesioning the obturator branch, the clinical application of successive lesions to increase denervation area, and outcomes in a patient receiving a second treatment with previously good results. To discuss relevant and technical factors for this specific case, we reviewed previous literature on hip joint radiofrequency and critically evaluated previous anatomic studies in the context of radiofrequency. The first treatment provided significant benefit for a period of 6 months. A second treatment was employed providing only mild to moderate benefit until his joint replacement surgery 4 months later. Literature review revealed studies of low quality secondary to small sample sizes, patient selection methodology, inclusion of patients with heterogenous etiologies for pain, variable needle placement techniques, and lack of measurement of functional outcomes. Case report and low quality studies in existing literature. Hip joint radiofrequency denervation is a promising avenue for adjunctive treatment of hip pain. Further cadaveric studies are required to clarify a multitude of technical parameters. Once these are well defined, future clinical studies should consider pain, functional, and economic outcomes in their design.

  10. The C-Port Distal Coronary Anastomotic Device Is Comparable With a Hand-Sewn Anastomosis: Human Histological Case Study.

    PubMed

    Balkhy, Husam H; Nisivaco, Sarah M; Husain, Aliya N; Jeevanandam, Valluvan; Arif, Quidsia

    Coronary artery bypass surgery is most commonly performed using a hand-sewn technique with a continuous monofilament suture. The C-Port distal anastomotic device is a miniature stapler designed to create an arteriotomy and attach the graft to the coronary artery all in one step. It is the only distal coronary anastomotic device currently approved for clinical use and can be useful in facilitating less invasive coronary surgery. This report examines the histological attributes of such an anastomosis in a patient who underwent heart transplantation approximately 1 year after robotic totally endoscopic stapled coronary bypass using the C-Port anastomotic device. There have been no previous reports of histological examination of this type of bypass graft in humans in the literature. We found that the C-Port single-shot stapled coronary anastomotic device had a similar histological appearance to a traditional hand-sewn technique using monofilament suture. The amount of inflammation around the anastomosis using the two techniques was found to be comparable in this histological case study in an explanted human heart. There was no evidence of increased neointimal hyperplasia. These findings add to the already known equivalent clinical patency rates of the C-Port device in coronary bypass procedures.

  11. Beyond Astro 101: A First Report on Applying Interactive Education Techniques to an Astronphysics Class for Majors

    NASA Astrophysics Data System (ADS)

    Perrin, Marshall D.; Ghez, A. M.

    2009-05-01

    Learner-centered interactive instruction methods now have a proven track record in improving learning in "Astro 101" courses for non-majors, but have rarely been applied to higher-level astronomy courses. Can we hope for similar gains in classes aimed at astrophysics majors, or is the subject matter too fundamentally different for those techniques to apply? We present here an initial report on an updated calculus-based Introduction to Astrophysics class at UCLA that suggests such techniques can indeed result in increased learning for major students. We augmented the traditional blackboard-derivation lectures and challenging weekly problem sets by adding online questions on pre-reading assignments (''just-in-time teaching'') and frequent multiple-choice questions in class ("Think-Pair-Share''). We describe our approach, and present examples of the new Think-Pair-Share questions developed for this more sophisticated material. Our informal observations after one term are that with this approach, students are more engaged and alert, and score higher on exams than typical in previous years. This is anecdotal evidence, not hard data yet, and there is clearly a vast amount of work to be done in this area. But our first impressions strongly encourage us that interactive methods should be able improve the astrophysics major just as they have improved Astro 101.

  12. Stress Management and Relaxation Techniques Use among Underserved Inpatients in an Inner City Hospital

    PubMed Central

    Gardiner, Paula; Sadikova, Ekaterina; Filippelli, Amanda C.; Mitchell, Suzanne; White, Laura F.; Saper, Robert; Kaptchuk, Ted J.; Jack, Brian W.; Fredman, Lisa

    2015-01-01

    Objective Little is known about the use of Stress Management and Relaxation Techniques (SMART) in racially diverse inpatients. We hope to identify socioeconomic status (SES) factors, health behavior factors, and clinical factors associated with the use of SMART. Design and Main Outcome Measures We conducted a secondary analysis of baseline data from 623 hospitalized patients enrolled in the Re-Engineered Discharge (RED) clinical trial. We assessed socio-demographic characteristics and use of SMART. We used bivariate and multivariate logistic regression to test the association of SMART with socio-demographic characteristics, health behaviors, and clinical factors. Results A total of 26.6% of participants reported using SMART and 23.6% used mind body techniques. Thirty six percent of work disabled patients, 39% of illicit drug users, and 38% of participants with depressive symptoms used SMART. Patients who both reported illicit drug use and screened positive for depression had significantly increased odds of using SMART [OR=4.94, 95% CI (1.59, 15.13)]. Compared to non-Hispanic whites, non-Hispanic blacks [0.55, (0.34 to 0.87)] and Hispanic/other race individuals [0.40, (0.20 to 0.76)] were less likely to use SMART. Conclusions We found greater utilization of SMART among all racial groups compared to previous national studies. In the inner city inpatient setting, patients with depression, illicit drug use, and work disability reported higher rates of using SMART. PMID:26051576

  13. Laryngotracheal transplantation: technical modifications and functional outcomes.

    PubMed

    Farwell, D Gregory; Birchall, Martin A; Macchiarini, Paolo; Luu, Quang C; de Mattos, Angelo M; Gallay, Brian J; Perez, Richard V; Grow, Matthew P; Ramsamooj, Rajen; Salgado, Moses D; Brodie, Hilary A; Belafsky, Peter C

    2013-10-01

    Laryngeal transplantation offers the potential for patients without a larynx to recover their voice, which is critical in our communication age. We report clinical and functional outcomes from a laryngotracheal transplant. Widespread adoption of this technique has been slowed due to the ethical concerns of life-long immunosuppression after a nonvital organ transplant. Our patient was already on immunosuppressive medication from prior kidney-pancreas transplantation, and therefore was not exposed to added long-term risk. We describe the unique technical advances, clinical course, and rehabilitation of this patient and the implications for future laryngeal transplantation. Case report. A laryngotracheal transplantation was performed in a 51-year-old prior kidney-pancreas transplant recipient presenting with complete laryngotracheal stenosis. Surgical modifications were made in the previously described technique related to retrieval, vascular supply, and reinnervation. This resulted in a robustly vascularized organ with well-perfused long-segment tracheal transplant and early return of motor reinnervation. A multidisciplinary approach resulted in a successful transplant without evidence of rejection to date. Postoperatively, the patient continues to rely on a tracheotomy but has had the return of an oral and nasal airway, vocalization, smell, and taste, all experienced for the first time in 11 years. We have demonstrated that our methods may result in a successful laryngotracheal transplant. We describe the preparation, surgical technique, rehabilitation, and interventions employed in achieving optimal outcomes. This report contributes valuable information on this rarely performed composite transplant. Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  14. Measurement of Thermal Properties of Rocks at Temperature up to 1,000°C with Transient Plane Source Techniques

    NASA Astrophysics Data System (ADS)

    Kim, S. K.; Lee, Y.

    2017-12-01

    A set of devices that can measure thermal properties of rocks over a temperature range from room temperature up to 1,000°C with transient plane source techniques (also known as a Hot Disk method) is introduced. It consists of a main control system (e.g., TPS 2500 S from Hot Disk), mica-insulated sensor, tubular furnace, N2 gas supplier, and pressure regulator. The TPS 2500 S is the core instrument designed for precise analysis of thermal transport properties including thermal conductivity, thermal diffusivity, and volumetric heat capacity. The mica-insulated sensor is composed of an insulated nickel double spiral, which is utilized for both transient heating and precise temperature reading; a mica insulator protects the sensor against mechanical and thermal damage at high temperatures. The tubular furnace can hold two rock core samples of 50-mm-diameter and 25-mm-height with increasing temperatures up to 1,000°C. N2 gas supplier and pressure regulator are used to keep the inside the furnace away from oxygen. Thermal properties of most rocks and minerals vary with increasing temperatures. Experimental measurements of thermal properties at high temperatures have been made mostly using laser flash, needle probe, and divided bar methods in the previous researches, and no previous measurements with the Hot Disk method have been reported yet. We report thermal conductivities, thermal diffusivities, and volumetric heat capacities determined by a transient plane heat source method for fused silica and mafic rock samples using the introduced transient plane source apparatus. The thermal properties of fused silica have been measured mainly over the temperature range from ambient temperature to 500°C. The results seem to agree moderately with the previously reported values by Birch and Clark (Am. J. Sci., 1940). We now check the possible causes of measurement errors in our measurements and prepare to measure thermal properties of the mafic rock samples at temperatures up to 1,000°C using the hot disk method.

  15. Facile preparation of an alternating copolymer-based high molecular shape-selective organic phase for reversed-phase liquid chromatography.

    PubMed

    Mallik, Abul K; Noguchi, Hiroki; Rahman, Mohammed Mizanur; Takafuji, Makoto; Ihara, Hirotaka

    2018-06-22

    The synthesis of a new alternating copolymer-grafted silica phase is described for the separation of shape-constrained isomers of polycyclic aromatic hydrocarbons (PAHs) and tocopherols in reversed-phase high-performance liquid chromatography (RP-HPLC). Telomerization of the monomers (octadecyl acrylate and N-methylmaleimide) was carried out with a silane coupling agent; 3-mercaptopropyltrimethoxysilane (MPS), and the telomer (T) was grafted onto porous silica surface to prepare the alternating copolymer-grafted silica phase (Sil-alt-T). The new hybrid material was characterized by elemental analyses, diffuse reflectance infrared Fourier transform (DRIFT) spectroscopy, and solid-state 13 C and 29 Si cross-polarization magic-angle spinning (CP/MAS) NMR spectroscopy. The results of 13 C CP/MAS NMR demonstrated that the alkyl chains of the grafted polymers in Sil-alt-T remained disordered, amorphous, and mobile represented by gauche conformational form. Separation abilities and molecular-shape selectivities of the prepared organic phase were evaluated by the separation of PAHs isomers and Standard Reference Material 869b, Column Selectivity Test Mixture for Liquid Chromatography, respectively and compared with commercially available octadecylsilylated silica (ODS) and C 30 columns as well as previously reported alternating copolymer-based column. The effectiveness of this phase is also demonstrated by the separation of tocopherol isomers. Oriented functional groups along the polymer main chains and cavity formations are investigated to be the driving force for better separation with multiple-interactions with the solutes. One of the advantages of the Sil-alt-T phase to that of the previously reported phase is the synthesis of the telomer first and then immobilized onto silica surface. In this case, the telomer was characterized easily with simple spectroscopic techniques and the molecular mass and polydispersity index of the telomer were determined by size exclusion chromatography (SEC) before grafting onto silica surface. Moreover, both of the monomers were commercially available. Therefore, the technique of preparation was very facile and better separation was achieved with the Sil-alt-T phase compared to the ODS, C 30 and other previously reported alternating copolymer-based columns. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Identification of novel Theileria genotypes from Grant's gazelle

    PubMed Central

    Hooge, Janis; Howe, Laryssa; Ezenwa, Vanessa O.

    2015-01-01

    Blood samples collected from Grant's gazelles (Nanger granti) in Kenya were screened for hemoparasites using a combination of microscopic and molecular techniques. All 69 blood smears examined by microscopy were positive for hemoparasites. In addition, Theileria/Babesia DNA was detected in all 65 samples screened by PCR for a ~450-base pair fragment of the V4 hypervariable region of the 18S rRNA gene. Sequencing and BLAST analysis of a subset of PCR amplicons revealed widespread co-infection (25/39) and the existence of two distinct Grant's gazelle Theileria subgroups. One group of 11 isolates clustered as a subgroup with previously identified Theileria ovis isolates from small ruminants from Europe, Asia and Africa; another group of 3 isolates clustered with previously identified Theileria spp. isolates from other African antelope. Based on extensive levels of sequence divergence (1.2–2%) from previously reported Theileria species within Kenya and worldwide, the Theileria isolates detected in Grant's gazelles appear to represent at least two novel Theileria genotypes. PMID:25973394

  17. Identification of novel Theileria genotypes from Grant's gazelle.

    PubMed

    Hooge, Janis; Howe, Laryssa; Ezenwa, Vanessa O

    2015-08-01

    Blood samples collected from Grant's gazelles (Nanger granti) in Kenya were screened for hemoparasites using a combination of microscopic and molecular techniques. All 69 blood smears examined by microscopy were positive for hemoparasites. In addition, Theileria/Babesia DNA was detected in all 65 samples screened by PCR for a ~450-base pair fragment of the V4 hypervariable region of the 18S rRNA gene. Sequencing and BLAST analysis of a subset of PCR amplicons revealed widespread co-infection (25/39) and the existence of two distinct Grant's gazelle Theileria subgroups. One group of 11 isolates clustered as a subgroup with previously identified Theileria ovis isolates from small ruminants from Europe, Asia and Africa; another group of 3 isolates clustered with previously identified Theileria spp. isolates from other African antelope. Based on extensive levels of sequence divergence (1.2-2%) from previously reported Theileria species within Kenya and worldwide, the Theileria isolates detected in Grant's gazelles appear to represent at least two novel Theileria genotypes.

  18. Anticipation of the landing shock phenomenon in flight simulation

    NASA Technical Reports Server (NTRS)

    Mcfarland, Richard E.

    1987-01-01

    An aircraft landing may be described as a controlled crash because a runway surface is intercepted. In a simulation model the transition from aerodynamic flight to weight on wheels involves a single computational cycle during which stiff differential equations are activated; with a significant probability these initial conditions are unrealistic. This occurs because of the finite cycle time, during which large restorative forces will accompany unrealistic initial oleo compressions. This problem was recognized a few years ago at Ames Research Center during simulation studies of a supersonic transport. The mathematical model of this vehicle severely taxed computational resources, and required a large cycle time. The ground strike problem was solved by a described technique called anticipation equations. This extensively used technique has not been previously reported. The technique of anticipating a significant event is a useful tool in the general field of discrete flight simulation. For the differential equations representing a landing gear model stiffness, rate of interception and cycle time may combine to produce an unrealistic simulation of the continuum.

  19. Management of First Branchial Cleft Anomalies via a Cartilage-Splitting Technique.

    PubMed

    Schmidt, Richard; Conrad, David; Field, Erin; O'Reilly, Robert

    2015-06-01

    First branchial cleft anomalies are uncommon lesions that often present as periauricular infections. They have high recurrence rates, due in part to scarring secondary to prior infections and their management. These lesions have a close relationship with the facial nerve, and most authors recommend its identification and dissection because of this relationship. Nonetheless, facial nerve palsy has been reported in up to 15% of cases. We describe a novel technique for the management of first branchial cleft anomalies. Such lesions that presented in an infra- or postauricular location were approached via an incision through the cartilage of the pinna, between the tragus and antitragus. This technique affords direct access to the lesion without the need for facial nerve dissection. Six patients were treated. Five had prior surgery, including 3 with previous attempts at excision. There were no complications. The median follow-up was 35 months. One patient developed a recurrence. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.

  20. Ahmed glaucoma valve implant: surgical technique and complications.

    PubMed

    Riva, Ivano; Roberti, Gloria; Oddone, Francesco; Konstas, Anastasios Gp; Quaranta, Luciano

    2017-01-01

    Implantation of Ahmed glaucoma valve is an effective surgical technique to reduce intraocular pressure in patients affected with glaucoma. While in the past, the use of this device was reserved to glaucoma refractory to multiple filtration surgical procedures, up-to-date mounting experience has encouraged its use also as a primary surgery for selected cases. Implantation of Ahmed glaucoma valve can be challenging for the surgeon, especially in patients who already underwent previous multiple surgeries. Several tips have to be acquired by the surgeon, and a long learning curve is always needed. Although the valve mechanism embedded in the Ahmed glaucoma valve decreases the risk of postoperative hypotony-related complications, it does not avoid the need of a careful follow-up. Complications related to this type of surgery include early and late postoperative hypotony, excessive capsule fibrosis around the plate, erosion of the tube or plate edge, and very rarely infection. The aim of this review is to describe surgical technique for Ahmed glaucoma valve implantation and to report related complications.

  1. Ahmed glaucoma valve implant: surgical technique and complications

    PubMed Central

    Riva, Ivano; Roberti, Gloria; Oddone, Francesco; Konstas, Anastasios GP; Quaranta, Luciano

    2017-01-01

    Implantation of Ahmed glaucoma valve is an effective surgical technique to reduce intraocular pressure in patients affected with glaucoma. While in the past, the use of this device was reserved to glaucoma refractory to multiple filtration surgical procedures, up-to-date mounting experience has encouraged its use also as a primary surgery for selected cases. Implantation of Ahmed glaucoma valve can be challenging for the surgeon, especially in patients who already underwent previous multiple surgeries. Several tips have to be acquired by the surgeon, and a long learning curve is always needed. Although the valve mechanism embedded in the Ahmed glaucoma valve decreases the risk of postoperative hypotony-related complications, it does not avoid the need of a careful follow-up. Complications related to this type of surgery include early and late postoperative hypotony, excessive capsule fibrosis around the plate, erosion of the tube or plate edge, and very rarely infection. The aim of this review is to describe surgical technique for Ahmed glaucoma valve implantation and to report related complications. PMID:28255226

  2. Measurement of Single Macromolecule Orientation by Total Internal Reflection Fluorescence Polarization Microscopy

    PubMed Central

    Forkey, Joseph N.; Quinlan, Margot E.; Goldman, Yale E.

    2005-01-01

    A new approach is presented for measuring the three-dimensional orientation of individual macromolecules using single molecule fluorescence polarization (SMFP) microscopy. The technique uses the unique polarizations of evanescent waves generated by total internal reflection to excite the dipole moment of individual fluorophores. To evaluate the new SMFP technique, single molecule orientation measurements from sparsely labeled F-actin are compared to ensemble-averaged orientation data from similarly prepared densely labeled F-actin. Standard deviations of the SMFP measurements taken at 40 ms time intervals indicate that the uncertainty for individual measurements of axial and azimuthal angles is ∼10° at 40 ms time resolution. Comparison with ensemble data shows there are no substantial systematic errors associated with the single molecule measurements. In addition to evaluating the technique, the data also provide a new measurement of the torsional rigidity of F-actin. These measurements support the smaller of two values of the torsional rigidity of F-actin previously reported. PMID:15894632

  3. Constraint-based integration of planning and scheduling for space-based observatory management

    NASA Technical Reports Server (NTRS)

    Muscettola, Nicola; Smith, Steven F.

    1994-01-01

    Progress toward the development of effective, practical solutions to space-based observatory scheduling problems within the HSTS scheduling framework is reported. HSTS was developed and originally applied in the context of the Hubble Space Telescope (HST) short-term observation scheduling problem. The work was motivated by the limitations of the current solution and, more generally, by the insufficiency of classical planning and scheduling approaches in this problem context. HSTS has subsequently been used to develop improved heuristic solution techniques in related scheduling domains and is currently being applied to develop a scheduling tool for the upcoming Submillimeter Wave Astronomy Satellite (SWAS) mission. The salient architectural characteristics of HSTS and their relationship to previous scheduling and AI planning research are summarized. Then, some key problem decomposition techniques underlying the integrated planning and scheduling approach to the HST problem are described; research results indicate that these techniques provide leverage in solving space-based observatory scheduling problems. Finally, more recently developed constraint-posting scheduling procedures and the current SWAS application focus are summarized.

  4. Neuro-proprioceptive facilitation in the re-education of functional problems in facial paralysis. A practical approach.

    PubMed

    Sardaru, D; Pendefunda, L

    2013-01-01

    Facial paralysis, in the form of Bell's syndrome, is an acute paralysis of idiopathic origin. Disability in patients with this medical condition is the result of impairment or loss of complex and multidimensional functions of the face like emotion expression through facial mimics, facial identity and communication. This study aimed to present new and improved practical manual techniques in the area of facial neuromuscular facilitations and to review the literature for disability indexes and facial nerve grading. We present the practical modality of using neuro-proprioceptive facilitation techniques, such as rhythmic initiation, repeated stretch (repeated contractions), combination of isotonics and percussion, and also report the effects of these techniques in three Bell's syndrome patients which were previously evaluated. Recovery from facial paralysis can be a difficult and long lasting process and the utilization of a grading system may help the physical therapist. The effects of this type of therapy may help_benefit the patient if the therapist is well trained and familiar with the neurophysiological background.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chandler, D.P.; Welt, M.; Leung, F.C.

    An efficient one-step injection technique for gene insertion into fertilized rainbow trout (Oncorhynchus mykiss) eggs is described, and basic parameters affecting egg survival are reported. Freshly fertilized rainbow trout eggs were injected in the perivitelline space with a recombinant mouse metallothionein-genomic bovine growth hormone (bGH) DNA construct using a 30-gauge hypodermic needle and a standard microinjection system. Relative to control, site of injection and DNA concentration did not affect the egg survival, but injections later than 3--4 hours post fertilization were detrimental. The injection technique permitted treatment of 100 eggs/hr with survivals up to 100%, resulting in a 4% DNAmore » uptake rate as indicated by DNA dot blot analysis. Positive dot blot results also indicated that the injected DNA is able to cross the vitelline membrane and persist for 50--60 days post hatching, obviating the need for direct injection into the germinal disk. Results are consistent with previous transgenic fish work, underscoring the usefulness of the technique for generating transgenic trout and salmonids. 24 refs., 6 figs., 3 tabs.« less

  6. Thoracoscopic diaphragmatic hernia repair in a warmblood mare.

    PubMed

    Röcken, Michael; Mosel, Gesine; Barske, Katharine; Witte, Tanja S

    2013-06-01

    To describe successful repair of a diaphragmatic hernia in a standing sedated horse using a minimally invasive thoracoscopic technique. Clinical report. Warmblood mare with a diaphragmatic hernia. An 18-year-old Warmblood mare with severe colic was referred for surgical treatment of small intestinal strangulation in a diaphragmatic defect. Twelve days after initial conventional colic surgery, left-sided laparoscopy in the standing sedated mare for diaphragmatic herniorrhaphy failed because the spleen obscured the hernia. One week later, a left-sided thoracoscopy was performed in the standing sedated horse and the hernia repaired by an intrathoracic suture technique. No long-term complications occurred (up to 4 years) and the mare returned to her previous athletic activity, followed by use as a broodmare. To avoid the high risks associated with general anesthesia, and to reduce surgical trauma and postoperative recovery, central diaphragmatic hernias are amenable to repair using a minimally invasive thoracoscopic technique in the standing sedated horse. © Copyright 2013 by The American College of Veterinary Surgeons.

  7. Critical layer thickness in In/sub 0. 2/Ga/sub 0. 8/As/GaAs single strained quantum well structures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fritz, I.J.; Gourley, P.L.; Dawson, L.R.

    1987-09-28

    We report accurate determination of the critical layer thickness (CLT) for single strained-layer epitaxy in the InGaAs/GaAs system. Our samples were molecular beam epitaxially grown, selectively doped, single quantum well structures comprising a strained In/sub 0.2/Ga/sub 0.8/As layer imbedded in GaAs. We determined the CLT by two sensitive techniques: Hall-effect measurements at 77 K and photoluminescence microscopy. Both techniques indicate a CLT of about 20 nm. This value is close to that determined previously (--15 nm) for comparable strained-layer superlattices, but considerably less than the value of --45 nm suggested by recent x-ray rocking-curve measurements. We show by a simplemore » calculation that photoluminescence microscopy is more than two orders of magnitude more sensitive to dislocations than x-ray diffraction. Our results re-emphasize the necessity of using high-sensitivity techniques for accurate determination of critical layer thicknesses.« less

  8. Summary: Update to ASTM guide E 1523 to charge control and charge referencing techniques in x-ray photoelectron spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baer, D.R.

    2005-05-01

    An updated version of the American Society for Testing and Materials (ASTM) guide E 1523 to the methods to charge control and charge referencing techniques in x-ray photoelectron spectroscopy has been released by ASTM [Annual Book of ASTM Standards Surface Analysis (American Society for Testing and Materials, West Conshohocken, PA, 2004), Vol. 03.06]. The guide is meant to acquaint x-ray photoelectron spectroscopy (XPS) users with the various charge control and charge referencing techniques that are and have been used in the acquisition and interpretation of XPS data from surfaces of insulating specimens. The current guide has been expanded to includemore » new references as well as recommendations for reporting information on charge control and charge referencing. The previous version of the document had been published in 1997 [D. R. Baer and K. D. Bomben, J. Vac. Sci. Technol. A 16, 754 (1998)].« less

  9. Programmed Lab Experiments for Biochemical Investigation of Quorum-Sensing Signal Molecules in Rhizospheric Soil Bacteria.

    PubMed

    Nievas, Fiorela L; Bogino, Pablo C; Giordano, Walter

    2016-05-06

    Biochemistry courses in the Department of Molecular Biology at the National University of Río Cuarto, Argentina, are designed for undergraduate students in biology, microbiology, chemistry, agronomy, and veterinary medicine. Microbiology students typically have previous coursework in general, analytical, and organic chemistry. Programmed sequences of lab experiments allow these students to investigate biochemical problems whose solution is feasible within the context of their knowledge and experience. We previously designed and reported a programmed lab experiment that familiarizes microbiology students with techniques for detection and characterization of quorum-sensing (QS) and quorum-quenching (QQ) signal molecules. Here, we describe a sequence of experiments designed to expand the understanding and capabilities of biochemistry students using techniques for extraction and identification of QS and QQ signal molecules from peanut rhizospheric soil bacteria, including culturing and manipulation of bacteria under sterile conditions. The program provides students with an opportunity to perform useful assays, draw conclusions from their results, and discuss possible extensions of the study. © 2016 by The International Union of Biochemistry and Molecular Biology, 44:256-262, 2016. © 2016 The International Union of Biochemistry and Molecular Biology.

  10. A thin, dense crust for Mercury

    NASA Astrophysics Data System (ADS)

    Sori, Michael M.

    2018-05-01

    Crustal thickness is a crucial geophysical parameter in understanding the geology and geochemistry of terrestrial planets. Recent development of mathematical techniques suggests that previous studies based on assumptions of isostasy overestimated crustal thickness on some of the solid bodies of the solar system, leading to a need to revisit those analyses. Here, I apply these techniques to Mercury. Using MESSENGER-derived elemental abundances, I calculate a map of grain density (average 2974 ± 89 kg/m3) which shows that Pratt isostasy is unlikely to be a major compensation mechanism of Mercury's topography. Assuming Airy isostasy, I find the best fit value for Mercury's mean crustal thickness is 26 ± 11 km, 25% lower than the most recently reported and previously thinnest number. Several geological implications follow from this relatively low value for crustal thickness, including showing that the largest impacts very likely excavated mantle material onto Mercury's surface. The new results also show that Mercury and the Moon have a similar proportion of their rocky silicates composing their crusts, and thus Mercury is not uniquely efficient at crustal production amongst terrestrial bodies. Higher resolution topography and gravity data, especially for the southern hemisphere, will be necessary to refine Mercury's crustal parameters further.

  11. Magnetic Analysis Techniques Applied to Desert Varnish

    NASA Technical Reports Server (NTRS)

    Schmidgall, E. R.; Moskowitz, B. M.; Dahlberg, E. D.; Kuhlman, K. R.

    2003-01-01

    Desert varnish is a black or reddish coating commonly found on rock samples from arid regions. Typically, the coating is very thin, less than half a millimeter thick. Previous research has shown that the primary components of desert varnish are silicon oxide clay minerals (60%), manganese and iron oxides (20-30%), and trace amounts of other compounds [1]. Desert varnish is thought to originate when windborne particles containing iron and manganese oxides are deposited onto rock surfaces where manganese oxidizing bacteria concentrate the manganese and form the varnish [4,5]. If desert varnish is indeed biogenic, then the presence of desert varnish on rock surfaces could serve as a biomarker, indicating the presence of microorganisms. This idea has considerable appeal, especially for Martian exploration [6]. Magnetic analysis techniques have not been extensively applied to desert varnish. The only previous magnetic study reported that based on room temperature demagnetization experiments, there were noticeable differences in magnetic properties between a sample of desert varnish and the substrate sandstone [7]. Based upon the results of the demagnetization experiments, the authors concluded that the primary magnetic component of desert varnish was either magnetite (Fe3O4) or maghemite ( Fe2O3).

  12. One-step direct-laser metal writing of sub-100 nm 3D silver nanostructures in a gelatin matrix

    NASA Astrophysics Data System (ADS)

    Kang, SeungYeon; Vora, Kevin; Mazur, Eric

    2015-03-01

    Developing an ability to fabricate high-resolution, 3D metal nanostructures in a stretchable 3D matrix is a critical step to realizing novel optoelectronic devices such as tunable bulk metal-dielectric optical devices and THz metamaterial devices that are not feasible with alternative techniques. We report a new chemistry method to fabricate high-resolution, 3D silver nanostructures using a femtosecond-laser direct metal writing technique. Previously, only fabrication of 3D polymeric structures or single-/few-layer metal structures was possible. Our method takes advantage of unique gelatin properties to overcome such previous limitations as limited freedom in 3D material design and short sample lifetime. We fabricate more than 15 layers of 3D silver nanostructures with a resolution of less than 100 nm in a stable dielectric matrix that is flexible and has high large transparency that is well-matched for potential applications in the optical and THz metamaterial regimes. This is a single-step process that does not require any further processing. This work will be of interest to those interested in fabrication methods that utilize nonlinear light-matter interactions and the realization of future metamaterials.

  13. Comparative factor analysis models for an empirical study of EEG data, II: A data-guided resolution of the rotation indeterminacy.

    PubMed

    Rogers, L J; Douglas, R R

    1984-02-01

    In this paper (the second in a series), we consider a (generic) pair of datasets, which have been analyzed by the techniques of the previous paper. Thus, their "stable subspaces" have been established by comparative factor analysis. The pair of datasets must satisfy two confirmable conditions. The first is the "Inclusion Condition," which requires that the stable subspace of one of the datasets is nearly identical to a subspace of the other dataset's stable subspace. On the basis of that, we have assumed the pair to have similar generating signals, with stochastically independent generators. The second verifiable condition is that the (presumed same) generating signals have distinct ratios of variances for the two datasets. Under these conditions a small elaboration of some elementary linear algebra reduces the rotation problem to several eigenvalue-eigenvector problems. Finally, we emphasize that an analysis of each dataset by the method of Douglas and Rogers (1983) is an essential prerequisite for the useful application of the techniques in this paper. Nonempirical methods of estimating the number of factors simply will not suffice, as confirmed by simulations reported in the previous paper.

  14. An Unusual Complication of Ventriculoperitoneal Shunt: Urinary Bladder Stone Case Report and Literature Review.

    PubMed

    Xu, Songtao; Sheng, Weixin; Qiu, Yufa; Wang, Jianguo

    2016-01-01

    Ventriculoperitoneal (V-P) shunt surgery is the most common technique used for the treatment of hydrocephalus. The migration of ventriculoperitoneal shunt to the bladder is rare. Only two cases have been previously reported in the literature. We report on a 38-year-old male who had hydrocephalus and V-P shunt for 12 years. Two years ago, he found himself with recurrent urinary tract infections, haematuria and urges incontinence, and then he was diagnosed with bladder perforation and merge stones. The patient had an abdominal operation to cut off and take out the shunt catheter, as well as a transurethral holmium laser lithotripsy. Bladder perforation and stones are rare examples of complications in V-P surgical procedures. Controlling the effective length of the terminal V-P shunt and modifying it appropriately can effectively reduce these complications.

  15. Evidence of a miscibility gap in the FeTe1-xSex polycrystalline samples prepared with a melting process

    NASA Astrophysics Data System (ADS)

    Sala, A.; Palenzona, A.; Bernini, C.; Caglieris, F.; Cimberle, M. R.; Ferdeghini, C.; Lamura, G.; Martinelli, A.; Pani, M.; Hecher, J.; Eisterer, M.; Putti, M.

    2014-05-01

    The study of overdoped FeTe1-xSex (0.5 < x < 1) polycrystalline superconductor samples is reported. The samples were prepared using a melting technique previously developed by our group. Increasing the Se content a phase separation related to the formation of FeSe inside the Fe(Se,Te) phase happens, as demonstrated by structural analysis and magnetic characterization. The proposed phase separation picture is likely the fingerprint of a miscibility gap in the Fe(Se,Te) system.

  16. Lightcurve Results for Eleven Asteroids

    NASA Astrophysics Data System (ADS)

    Gartrelle, Gordon M.

    2012-04-01

    Differential photometry techniques were used to develop lightcurves, rotation periods and amplitudes for eleven main-belt asteroids: 833 Monica, 962 Aslog, 1020 Arcadia, 1082 Pirola, 1097 Vicia, 1122 Lugduna, 1145 Robelmonte, 1253 Frisia, 1256 Normannia, 1525 Savolinna, and 2324 Janice. Ground-based observations from Badlands Observatory (BLO) in Quinn, SD, as well as the University of North Dakota Observatory (UND) in Grand Forks, ND, provided the data for the project. A search of the asteroid lightcurve database (LCDB) did not reveal any previously reported results for seven of the eleven targets in this study.

  17. A cost-effective device for the rapid transfer of gel-separated proteins onto membranes.

    PubMed

    Tam, Hann W; Huang, Yu-Chen; Tam, Ming F

    2009-03-01

    We describe here the fabrication of a cost-effective semi-dry blotting apparatus for the transfer of proteins onto membranes. Graphite sheets were used as electrodes. Protein mixtures were separated on NuPAGE 4% to 12% polyacrylamide gradient gels. With a Tris-bicine buffer, we demonstrated that close to 80% of the proteins with apparent molecular mass of 80kDa or less were removed from the gels after 8min of blotting. The process is much faster than the techniques reported previously in the literature.

  18. Knowledge discovery from structured mammography reports using inductive logic programming.

    PubMed

    Burnside, Elizabeth S; Davis, Jesse; Costa, Victor Santos; Dutra, Inês de Castro; Kahn, Charles E; Fine, Jason; Page, David

    2005-01-01

    The development of large mammography databases provides an opportunity for knowledge discovery and data mining techniques to recognize patterns not previously appreciated. Using a database from a breast imaging practice containing patient risk factors, imaging findings, and biopsy results, we tested whether inductive logic programming (ILP) could discover interesting hypotheses that could subsequently be tested and validated. The ILP algorithm discovered two hypotheses from the data that were 1) judged as interesting by a subspecialty trained mammographer and 2) validated by analysis of the data itself.

  19. Discovering Communicable Scientific Knowledge from Spatio-Temporal Data

    NASA Technical Reports Server (NTRS)

    Schwabacher, Mark; Langley, Pat; Norvig, Peter (Technical Monitor)

    2001-01-01

    This paper describes how we used regression rules to improve upon a result previously published in the Earth science literature. In such a scientific application of machine learning, it is crucially important for the learned models to be understandable and communicable. We recount how we selected a learning algorithm to maximize communicability, and then describe two visualization techniques that we developed to aid in understanding the model by exploiting the spatial nature of the data. We also report how evaluating the learned models across time let us discover an error in the data.

  20. Jurassic Diabase from Leesburg, VA: A Proposed Lunar Simulant

    NASA Technical Reports Server (NTRS)

    Taylor, Patrick T.; Lowman, P. D.; Nagihara, Seiichi; Milam, M. B.; Nakamura, Yosio

    2008-01-01

    A study of future lunar seismology and heat flow is being carried out as part of the NASA Lunar Sortie Science Program. This study will include new lunar drilling techniques, using a regolith simulant, for emplacement of instruments. Previous lunar simulants, such as JSC-1 and MLS-1, were not available when the study began, so a local simulant source was required. Diabase from a quarry at Leeseburg, Virginia, was obtained from the Luck Stone Corporation. We report here initial results of a petrographic examination of this rock, GSC-1 henceforth.

  1. Jurassic Diabase from Leesburg, VA: A Proposed Lunar Simulant

    NASA Technical Reports Server (NTRS)

    Taylor, P. T.; Lowman, P. D.; Nagihara, Seiichi; Milam, M. B.; Nakamura, Yosio

    2008-01-01

    A study of future lunar seismology and heat flow is being carried out as part of the NASA Lunar Sortie Science Program [1].This study will include new lunar drilling techniques, using a regolith simulant, for emplacement of instruments. Previous lunar simulants, such as JSC-I and MLS-l, were not available when the study began, so a local simulant source was required. Diabase from a quarry at Leesburg, Virginia, was obtained from the Luck Stone Corporation. We report here initial results of a petrographic examination of this rock, GSC-1 henceforth.

  2. Highly sensitive and simple SERS substrate based on photochemically generated carbon nanotubes-gold nanorods hybrids.

    PubMed

    Caires, A J; Vaz, R P; Fantini, C; Ladeira, L O

    2015-10-01

    We report a simple and easy formation of hybrids between multi-wall carbon nanotubes and gold nanorods by one-pot in situ photochemical synthesis. Measurements of surface-enhanced Raman scattering (SERS) through the effect "coffee ring" in visible and near infrared (NIR) show high sensitivity with detection of nanomolar concentrations of aromatic dyes. The formation of nanocomposites between carbon nanotubes and gold nanorods without chemical binders simplifies the preparation. Photochemical synthesis is an advance over the techniques previously published. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Analysis of computer images in the presence of metals

    NASA Astrophysics Data System (ADS)

    Buzmakov, Alexey; Ingacheva, Anastasia; Prun, Victor; Nikolaev, Dmitry; Chukalina, Marina; Ferrero, Claudio; Asadchikov, Victor

    2018-04-01

    Artifacts caused by intensely absorbing inclusions are encountered in computed tomography via polychromatic scanning and may obscure or simulate pathologies in medical applications. To improve the quality of reconstruction if high-Z inclusions in presence, previously we proposed and tested with synthetic data an iterative technique with soft penalty mimicking linear inequalities on the photon-starved rays. This note reports a test at the tomographic laboratory set-up at the Institute of Crystallography FSRC "Crystallography and Photonics" RAS in which tomographic scans were successfully made of temporary tooth without inclusion and with Pb inclusion.

  4. Sensors and detectors based on superconducting devices. July 1988-June 1989 (Citations from the COMPENDEX data base). Report for July 1988-June 1989

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1989-07-01

    This bibliography contains citations concerning gradiometers, magnetometers, and infrared detectors which use superconductors to improve sensitivity. Applications include biomagnetic measurements for medical studies, gravity-wave experiments, geomagnetism and ocean-bottom magnetic exploration, galvanometers and voltmeters, and bolometers and radiometers. Some articles refer to design considerations for cooling systems for the sensors and detectors, and fabrication techniques for SQUIDs (superconducting quantum interference devices.) (This updated bibliography contains 74 citations, all of which are new entries to the previous edition.)

  5. Sensors and detectors based on superconducting devices. January 1970-June 1988 (Citations from the COMPENDEX data base). Report for January 1970-June 1988

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1989-07-01

    This bibliography contains citations concerning gradiometers, magnetometers, and infrared detectors which use superconductors to improve sensitivity. Applications include biomagnetic measurements for medical studies, gravity-wave experiments, geomagnetism and ocean-bottom magnetic exploration, galvanometers and voltmeters, and bolometers and radiometers. Some articles refer to design considerations for cooling systems for the sensors and detectors, and fabrication techniques for SQUIDs (superconducting quantum interference devices.) (This updated bibliography contains 394 citations, none of which are new entries to the previous edition.)

  6. Sensors and detectors based on superconducting devices. January 1970-June 1988 (Citations from the Engineering Index data base). Report for January 1970-June 1988

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1988-07-01

    This bibliography contains citations concerning gradiometers, magnetometers, and infrared detectors which use superconductors to improve sensitivity. Applications include biomagnetic measurements for medical studies, gravity-wave experiments, geomagnetism, and ocean-bottom magnetic exploration, galvanometers and voltmeters, and bolometers, and radiometers. Some articles refer to design considerations for cooling systems for the sensors and detectors, and fabrication techniques for squids (superconducting quantum interference devices.) (This updated bibliography contains 394 citations, 71 of which are new entries to the previous edition.)

  7. External doses of residents near Semipalatinsk nuclear test site.

    PubMed

    Takada, J; Hoshi, M; Nagatomo, T; Yamamoto, M; Endo, S; Takatsuji, T; Yoshikawa, I; Gusev, B I; Sakerbaev, A K; Tchaijunusova, N J

    1999-12-01

    Accumulated external radiation doses of residents near the Semipalatinsk nuclear test site of the former USSR are presented as a results of study by the thermoluminescence technique for bricks sampled at several settlements in 1995 and 1996. The external doses that we evaluated from exposed bricks were up to about 100 cGy for resident. The external doses at several points in the center of Semipalatinsk City ranged from a background level to 60 cGy, which was remarkably high compared with the previously reported values based on military data.

  8. Ditching Tests of a 1/18-Scale Model of the Lockheed Constellation Airplane with Speedpak Attached

    NASA Technical Reports Server (NTRS)

    Fisher, Lloyd J.; Thompson, William C.

    1949-01-01

    Results of previous model ditching tests of the Lockheed Constellation airplane are reported. Further model tests have been made to determine the probable ditching characteristics and the proper ditching technique for the airplane with the Speedpak attached. This paper presents the results of these tests. Design information was furnished by the Lockheed Aircraft Corporation. A three-vies drawing of the airplane with the Speedpak attached is shown. The tests were made in calm water at the Langley tank no.2 monorail.

  9. Chromosome rearrangements in canine fibrosarcomas.

    PubMed

    Sargan, D R; Milne, B S; Hernandez, J Aguirre; O'Brien, P C M; Ferguson-Smith, M A; Hoather, T; Dobson, J M

    2005-01-01

    We have previously reported the use of six- and seven-color paint sets in the analysis of canine soft tissue sarcomas. Here we combine this technique with flow sorting of translocation chromosomes, reverse painting, and polymerase chain reaction (PCR) analysis of the gene content of the reverse paint in order to provide a more detailed analysis of cytogenetic abnormalities in canine tumors. We examine two fibrosarcomas, both from female Labrador retrievers, and show abnormalities in chromosomes 11 and 30 in both cases. Evidence of involvement of TGFBR1 is presented for one tumor.

  10. Discovering Communicable Models from Earth Science Data

    NASA Technical Reports Server (NTRS)

    Schwabacher, Mark; Langley, Pat; Potter, Christopher; Klooster, Steven; Torregrosa, Alicia

    2002-01-01

    This chapter describes how we used regression rules to improve upon results previously published in the Earth science literature. In such a scientific application of machine learning, it is crucially important for the learned models to be understandable and communicable. We recount how we selected a learning algorithm to maximize communicability, and then describe two visualization techniques that we developed to aid in understanding the model by exploiting the spatial nature of the data. We also report how evaluating the learned models across time let us discover an error in the data.

  11. Terahertz study of hole transport in pentacene thin films

    NASA Astrophysics Data System (ADS)

    Engelbrecht, Stefan G.; Prinz, Markus; Arend, Thomas R.; Kersting, Roland

    2014-10-01

    Terahertz electromodulation spectroscopy is a novel tool for studying charge carrier transport in polycrys­talline thin films. The technique selectively probes the high-frequency response of mobile carriers and is insensitive to scattering at grain boundaries as well as to trapping processes. In thin films of pentacene we find a hole mobility of 21 cm2 /Vs, which exceeds the largest previously reported values obtained in poly­ crystalline pentacene. Additionally, the data provide an upper limit of the hole conductivity effective mass of mh ≍ 0.8 me.

  12. Internal combustion engine fuel controls. December 1970-December 1989 (Citations from the US Patent data base). Report for December 1970-December 1989

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1990-01-01

    This bibliography contains citations of selected patents concerning fuel control devices, and methods used to regulate speed and load in internal combustion engines. Techniques utilized to control air-fuel ratios by sensing pressure, temperature, and exhaust composition, and the employment of electronic and feedback devices are discussed. Methods used for engine protection and optimum fuel conservation are considered. (This updated bibliography contains 327 citations, 160 of which are new entries to the previous edition.)

  13. 1976 annual summary report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1978-03-01

    Abstracts of papers published during the previous calendar year, arranged in accordance with the project titles used in the USDOE Schedule 189 Budget Proposals, are presented. The collection of abstracts supplements the listing of papers published in the Schedule 189. The following subject areas are represented: high-energy physics; nuclear physics; basic energy sciences (nuclear science, materials sciences, solid state physics, materials chemistry); molecular, mathematical, and earth sciences (fundamental interactions, processes and techniques, mathematical and computer sciences); environmental research and development; physical and technological studies (characterization, measurement and monitoring); and nuclear research and applications.

  14. Nuclear techniques for the on-line bulk analysis of carbon in coal-fired power stations.

    PubMed

    Sowerby, B D

    2009-09-01

    Carbon trading schemes usually require large emitters of CO(2), such as coal-fired power stations, to monitor, report and be audited on their CO(2) emissions. The emission price provides a significant additional incentive for power stations to improve efficiency. In the present paper, previous work on the bulk determination of carbon in coal is reviewed and assessed. The most favourable method is that based on neutron inelastic scattering. The potential role of on-line carbon analysers in improving boiler efficiency and in carbon accounting is discussed.

  15. Remote distribution of a mode-locked pulse train with sub 40-as jitter

    NASA Astrophysics Data System (ADS)

    Chen, Yi-Fei; Jiang, Jie; Jones, David J.

    2006-12-01

    Remote transfer of an ultralow-jitter microwave frequency reference signal is demonstrated using the pulse trains generated by a mode-locked fiber laser. The timing jitter in a ~ 30-m fiber link is reduced to 38 attoseconds (as) integrated over a bandwidth from 1 Hz to 10 MHz via active stabilization which represents a significant improvement over previously reported jitter performance. Our approach uses an all-optical generation of the synchronization error signal and an accompanying out-of-loop optical detection technique to verify the jitter performance.

  16. Occipitocervical fusions in children. Retrospective analysis and technical considerations.

    PubMed

    Rodgers, W B; Coran, D L; Emans, J B; Hresko, M T; Hall, J E

    1999-07-01

    This report presents a retrospective analysis of the authors' experience with occipitocervical fusions in children and adolescents during the last 2 decades. A description of an operative technique devised by the senior author (JEH), and a comparison of the results using this and other methods of fusion are given. Twenty-three patients underwent occipitocervical fusion. Fifteen of the patients were operated on using the authors' technique. To achieve stable fixation of the distal cervical vertebra a threaded Kirschner wire was passed transversely through the spinous process; occipital fixation was achieved by the traditional method of wiring corticocancellous bone graft to the skull through burr holes. The occipital wires then were wrapped around the Kirschner wire and the graft was cradled in the resulting nest. Halo immobilization was used in 10 patients for an average of 12.5 weeks (range, 6-24 weeks). Twenty-two patients achieved successful fusion at an average followup of 5.8 years (range, 1-14.33 years). Several complications, including transient quadriplegia in one patient, pseudarthrosis in two (one of which persists), hardware fixation failure in one, unintended distal extension of the fusion, pneumonia, wound infection, halo pin infection, skin breakdown under the halo vest, hydrocephalus, cerebrospinal fluid leak, and traumatic fusion fracture were encountered. Results using the technique described herein are comparable with or better than the results reported in the previous literature, and the results of the patients in this series in whom the technique was not used.

  17. Endolithic phototrophs in built and natural stone.

    PubMed

    Gaylarde, Christine C; Gaylarde, Peter M; Neilan, Brett A

    2012-08-01

    Lichens, algae and cyanobacteria have been detected growing endolithically in natural rock and in stone buildings in various countries of Australasia, Europe and Latin America. Previously these organisms had mainly been described in natural carbonaceous rocks in aquatic environments, with some reports in siliceous rocks, principally from extremophilic regions. Using various culture and microscopy methods, we have detected endoliths in siliceous stone, both natural and cut, in humid temperate and subtropical climates. Such endolithic growth leads to degradation of the stone structure, not only by mechanical means, but also by metabolites liberated by the cells. Using in vitro culture, transmission, optical and fluorescence microscopy, and confocal laser scanning microscopy, both coccoid and filamentous cyanobacteria and algae, including Cyanidiales, have been identified growing endolithically in the facades of historic buildings built from limestone, sandstone, granite, basalt and soapstone, as well as in some natural rocks. Numerically, the most abundant are small, single-celled, colonial cyanobacteria. These small phototrophs are difficult to detect by standard microscope techniques and some of these species have not been previously reported within stone.

  18. Basic research and clinical application of beta-tricalcium phosphate (β-TCP).

    PubMed

    Tanaka, T; Komaki, H; Chazono, M; Kitasato, S; Kakuta, A; Akiyama, S; Marumo, K

    2017-09-01

    The mechanism of bone substitute resorption involves two processes: solution-mediated and cell-mediated disintegration. In our previous animal studies, the main resorption process of beta-tricalcium phosphate (β-TCP) was considered to be cell-mediated disintegration by TRAP-positive cells. Thus, osteoclast-mediated resorption of β-TCP is important for enabling bone formation. We also report the results of treatment with β-TCP graft in patients since 1989. Two to three weeks after implantation, resorption of β-TCP occurred from the periphery, and then continued toward the center over time. Complete or nearly complete bone healing was achieved in most cases within a few years and was dependent upon the amount of implanted material, the patient's age, and the type of bone (cortical or cancellous). We have previously reported that an injectable complex of β-TCP granules and collagen supplemented with rhFGF-2 enabled cortical bone regeneration of rabbit tibiae. Based on the experimental results, we applied this technique to the patients with femoral and humeral fractures in elderly patients, and obtained bone union. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  19. Effect of elevated substrate temperature deposition on the mechanical losses in tantala thin film coatings

    NASA Astrophysics Data System (ADS)

    Vajente, G.; Birney, R.; Ananyeva, A.; Angelova, S.; Asselin, R.; Baloukas, B.; Bassiri, R.; Billingsley, G.; Fejer, M. M.; Gibson, D.; Godbout, L. J.; Gustafson, E.; Heptonstall, A.; Hough, J.; MacFoy, S.; Markosyan, A.; Martin, I. W.; Martinu, L.; Murray, P. G.; Penn, S.; Roorda, S.; Rowan, S.; Schiettekatte, F.; Shink, R.; Torrie, C.; Vine, D.; Reid, S.; Adhikari, R. X.

    2018-04-01

    Brownian thermal noise in dielectric multilayer coatings limits the sensitivity of current and future interferometric gravitational wave detectors. In this work we explore the possibility of improving the mechanical losses of tantala, often used as the high refractive index material, by depositing it on a substrate held at elevated temperature. Promising results have been previously obtained with this technique when applied to amorphous silicon. We show that depositing tantala on a hot substrate reduced the mechanical losses of the as-deposited coating, but subsequent thermal treatments had a larger impact, as they reduced the losses to levels previously reported in the literature. We also show that the reduction in mechanical loss correlates with increased medium range order in the atomic structure of the coatings using x-ray diffraction and Raman spectroscopy. Finally, a discussion is included on our results, which shows that the elevated temperature deposition of pure tantala coatings does not appear to reduce mechanical loss in a similar way to that reported in the literature for amorphous silicon; and we suggest possible future research directions.

  20. Vibrational Mode-Specific Autodetachment and Coupling of CH2CN-

    NASA Astrophysics Data System (ADS)

    Lyle, Justin; Mabbs, Richard

    2017-06-01

    The Cyanomethyl Anion, CH_{2}CN-, and neutral radical have been studied extensively, with several findings of autodetachment about the totally symmetric transition, as well as high resolution experiments revealing symmetrically forbidden and weak vibrational features. We report photoelectron spectra using the Velocity-Mapped Imaging Technique in 1-2 \\wn increments over a range of 13460 to 15384 \\wn that has not been previously examined. These spectra include excitation of the ground state cyanomethyl anion into the direct detachment thresholds of previously reported vibrational modes for the neutral radical. Significant variations from Franck-Condon behavior were observed in the branching ratios for resolved vibrational features for excitation in the vicinity of the thresholds involving the νb{3} and νb{5} modes. These are consistent with autodetachment from rovibrational levels of a dipole bound state acting as a resonance in the detachment continuum. The autodetachment channels involve single changes in vibrational quantum number, consistent with the vibrational propensity rule but in some cases reveal relaxation to a different vibrational mode indicating coupling between the modes and/or a breakdown of the normal mode approximation.

  1. Techniques for analyzing the impacts of certain electric-utility ratemaking and regulatory-policy concepts. Glossary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1980-08-01

    This document, Glossary, is the first in a series of reports to identify, describe, and apply techniques for analyzing the impacts of certain electric utility concepts. This report was developed with a focus on the currently evolving issues of ratemaking, especially as they might be expected to arise under Sections 101, 111, 113, 114, 131, 132, and 210 of the P.U.R.P.A. of 1978. Because the evolutionary process of ratemaking has led to multiple proceedings and changes of inference in some terms, the glossary attempts to delineate these changes where appropriate. Definitions not uniquely related to ratemaking are included if theymore » are likely to be used in ratemaking proceedings. To avoid unnecessary duplication of effort and expense, the compilers relied heavily on previously developed, publicly available glossaries and definitions developed by organizations such as Edison Electric Institute, the Electric Power Research Institute, and the Institute of Electrical and Electronics Engineers. Existing definitions were revised and new ones were developed as appropriate.« less

  2. Direct pelvic access percutaneous nephrolithotomy in management of ectopic kidney stone: a case report and literature review.

    PubMed

    Mehmet, Rifaioglu Murat; Rustu, Yalcinkaya Fatih; Hanefi, Bayarogullari; Mursel, Davarci; Fusun, Aydogan; Mehmet, Inci

    2013-01-01

    Percutaneous nephrolithotomy (PNL) is an effective procedure for the treatment of patients with large or complex stones. PNL is challenging in anomalous kidneys, certain patients, such as those with renal ectopia. It is unable to undergo PNL in conventional technique safely in these cases. We presented a case report of laparoscopic-assisted PNL via direct pelvic puncture in a pelvic kidney stone and discussed previous published literature. A 49-year-old man presented with right lower quadrant pain and hematuria. Intravenous pyelography and three-dimensional computerized tomography revealed an opaque 2.7 × 1.7 cm pelvis renalis stone in a right side ectopic pelvic kidney with grade III hydronephrosis. Laparoscopic-assisted tubeless PNL was performed to remove the calculus. Laparoscopic-assisted PNL as a minimally invasive therapy in ectopic kidney has many advantages. Our case showed that, in pelvic ectopic kidney with pelvic stones greater than 1.5 cm in size, laparoscopic-assisted PNL via direct pelvis puncture is a safe and effective technique.

  3. Remotely deployable aerial inspection using tactile sensors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MacLeod, C. N.; Cao, J.; Pierce, S. G.

    For structural monitoring applications, the use of remotely deployable Non-Destructive Evaluation (NDE) inspection platforms offer many advantages, including improved accessibility, greater safety and reduced cost, when compared to traditional manual inspection techniques. The use of such platforms, previously reported by researchers at the University Strathclyde facilitates the potential for rapid scanning of large areas and volumes in hazardous locations. A common problem for both manual and remote deployment approaches lies in the intrinsic stand-off and surface coupling issues of typical NDE probes. The associated complications of these requirements are obviously significantly exacerbated when considering aerial based remote inspection and deployment,more » resulting in simple visual techniques being the preferred sensor payload. Researchers at Bristol Robotics Laboratory have developed biomimetic tactile sensors modelled on the facial whiskers (vibrissae) of animals such as rats and mice, with the latest sensors actively sweeping their tips across the surface in a back and forth motion. The current work reports on the design and performance of an aerial inspection platform and the suitability of tactile whisking sensors to aerial based surface monitoring applications.« less

  4. Shape memory alloy wire for self-sensing servo actuation

    NASA Astrophysics Data System (ADS)

    Josephine Selvarani Ruth, D.; Dhanalakshmi, K.

    2017-01-01

    This paper reports on the development of a straightforward approach to realise self-sensing shape memory alloy (SMA) wire actuated control. A differential electrical resistance measurement circuit (the sensorless signal conditioning (SSC) circuit) is designed; this sensing signal is directly used as the feedback for control. Antagonistic SMA wire actuators designed for servo actuation is realized in self-sensing actuation (SSA) mode for direct control with the differential electrical resistance feedback. The self-sensing scheme is established on a 1-DOF manipulator with the discrete time sliding mode controls which demonstrates good control performance, whatever be the disturbance and loading conditions. The uniqueness of this work is the design of the generic electronic SSC circuit for SMA actuated system, for measurement and control. With a concern to the implementation of self-sensing technique in SMA, this scheme retains the systematic control architecture by using the sensing signal (self-sensed, electrical resistance corresponding to the system position) for feedback, without requiring any processing as that of the methods adopted and reported previously for SSA techniques of SMA.

  5. Online Error Reporting for Managing Quality Control Within Radiology.

    PubMed

    Golnari, Pedram; Forsberg, Daniel; Rosipko, Beverly; Sunshine, Jeffrey L

    2016-06-01

    Information technology systems within health care, such as picture archiving and communication system (PACS) in radiology, can have a positive impact on production but can also risk compromising quality. The widespread use of PACS has removed the previous feedback loop between radiologists and technologists. Instead of direct communication of quality discrepancies found for an examination, the radiologist submitted a paper-based quality-control report. A web-based issue-reporting tool can help restore some of the feedback loop and also provide possibilities for more detailed analysis of submitted errors. The purpose of this study was to evaluate the hypothesis that data from use of an online error reporting software for quality control can focus our efforts within our department. For the 372,258 radiologic examinations conducted during the 6-month period study, 930 errors (390 exam protocol, 390 exam validation, and 150 exam technique) were submitted, corresponding to an error rate of 0.25 %. Within the category exam protocol, technologist documentation had the highest number of submitted errors in ultrasonography (77 errors [44 %]), while imaging protocol errors were the highest subtype error for computed tomography modality (35 errors [18 %]). Positioning and incorrect accession had the highest errors in the exam technique and exam validation error category, respectively, for nearly all of the modalities. An error rate less than 1 % could signify a system with a very high quality; however, a more likely explanation is that not all errors were detected or reported. Furthermore, staff reception of the error reporting system could also affect the reporting rate.

  6. Rapid brain death caused by a cerebellar abscess with Fusobacterium nucleatum in a young man with drug abuse: a case report

    PubMed Central

    2014-01-01

    Background Fusobacterium nucleatum is a strict anaerobic microorganism that causes disease entities such as periodontal and soft tissue abscesses, pulmonary and intraabdominal infections and very rarely intracerebral infections. Case presentation Here, we report the rare case of a previously healthy 25-year-old German man with a cerebellar abscess caused by Fusobacterium nucleatum that resulted in rapid brain death. Toxicological screening showed positivity for amphetamines and cannabis. The diagnosis was obtained by polymerase chain reaction amplification of bacterial deoxyribonucleic acid in cerebrospinal fluid. Conclusions In drug users clinicians should think about rare causes of brain abscesses/meningitis. Early diagnosis is necessary and justifies the use of molecular techniques. PMID:24915846

  7. Do religion and religiosity have anything to do with alcohol consumption patterns? Evidence from two fish landing sites on Lake Victoria Uganda.

    PubMed

    Tumwesigye, Nazarius M; Atuyambe, Lynn; Kibira, Simon P S; Wabwire-Mangen, Fred; Tushemerirwe, Florence; Wagner, Glenn J

    2013-09-01

    Fish landing sites have high levels of harmful use of alcohol. This paper examines the role of religion and religiosity on alcohol consumption at two fish landing sites on Lake Victoria in Uganda. Questionnaires were administered to randomly selected people at the sites. Dependent variables included alcohol consumption during the previous 30 days, whereas the key independent variables were religion and religiosity. Bivariate and multivariate analysis techniques were applied. People reporting low religiosity were five times more likely to have consumed alcohol (95% confidence interval: 2.45-10.04) compared with those reporting low/average religiosity. Religion and religiosity are potential channels for controlling alcohol use.

  8. Endovascular stenting of a chronic ruptured type B thoracic aortic dissection, a second chance: a case report.

    PubMed

    Arshad, Ali; Khan, Sumaira L; Whitaker, Simon C; Macsweeney, Shane T

    2008-02-07

    We aim to highlight the need for awareness of late complications of endovascular thoracic aortic stenting and the need for close follow-up of patients treated by this method. We report the first case in the English literature of an endovascular repair of a previously stented, ruptured chronic Stanford type B thoracic aortic dissection re-presenting with a type III endoleak of the original repair. Endovascular thoracic stenting is now a widely accepted technique for the treatment of thoracic aortic dissection and its complications. Long term follow up is necessary to ensure that late complications are identified and treated appropriately. In this case of type III endoleak, although technically challenging, endovascular repair was feasible and effective.

  9. Correction of facial and mandibular asymmetry using a computer aided design/computer aided manufacturing prefabricated titanium implant.

    PubMed

    Watson, Jason; Hatamleh, Muhanad; Alwahadni, Ahed; Srinivasan, Dilip

    2014-05-01

    Patients with significant craniofacial asymmetry may have functional problems associated with their occlusion and aesthetic concerns related to the imbalance in soft and hard tissue profiles. This report details a case of facial asymmetry secondary to left mandible angle deficiency due to undergoing previous radiotherapy. We describe the correction of the bony deformity using computer aided design/computer aided manufacturing custom-made titanium onlay using novel direct metal laser sintering. The direct metal laser sintering onlay proved a very accurate operative fit and showed a good aesthetic correction of the bony defect with no reported complications postoperatively. It is a useful low-morbidity technique, and there is no resorption or associated donor-site complications.

  10. Gastric Outlet Obstruction--An Unexpected Complication during Coca-Cola Therapy for a Gastric Bezoar: A Case Report and Literature Review.

    PubMed

    Lu, Lei; Zhang, Xiao-Feng

    2016-01-01

    Gastric bezoars are concretions of undigested material, and Coca-Cola therapy is an easy, efficacious and safe approach for bezoar treatment. Gastric outlet obstruction due to a migratory gastric bezoar during Coca-Cola therapy is an uncommon presentation and, to the best of our knowledge, no cases have been previously reported. We herein describe one such case with no known predisposing factors that recovered via the endoscopic technique. A thorough literature search was performed, which yielded eight relevant patients from seven publications, all of who developed gastrointestinal obstruction during dissolution treatment and recovered uneventfully after surgical intervention. In conclusion, this potential complication should be kept in mind in the event that alternative treatment is necessary.

  11. New semiconductor laser technology for gas sensing applications in the 1650nm range

    NASA Astrophysics Data System (ADS)

    Morrison, Gordon B.; Sherman, Jes; Estrella, Steven; Moreira, Renan L.; Leisher, Paul O.; Mashanovitch, Milan L.; Stephen, Mark; Numata, Kenji; Wu, Stewart; Riris, Haris

    2017-08-01

    Atmospheric methane (CH4) is the second most important anthropogenic greenhouse gas with approximately 25 times the radiative forcing of carbon dioxide (CO2) per molecule. CH4 also contributes to pollution in the lower atmosphere through chemical reactions leading to ozone production. Recent developments of LIDAR measurement technology for CH4 have been previously reported by Goddard Space Flight Center (GSFC). In this paper, we report on a novel, high-performance tunable semiconductor laser technology developed by Freedom Photonics for the 1650nm wavelength range operation, and for LIDAR detection of CH4. Devices described are monolithic, with simple control, and compatible with low-cost fabrication techniques. We present 3 different types of tunable lasers implemented for this application.

  12. Constructing experimental designs for discrete-choice experiments: report of the ISPOR Conjoint Analysis Experimental Design Good Research Practices Task Force.

    PubMed

    Reed Johnson, F; Lancsar, Emily; Marshall, Deborah; Kilambi, Vikram; Mühlbacher, Axel; Regier, Dean A; Bresnahan, Brian W; Kanninen, Barbara; Bridges, John F P

    2013-01-01

    Stated-preference methods are a class of evaluation techniques for studying the preferences of patients and other stakeholders. While these methods span a variety of techniques, conjoint-analysis methods-and particularly discrete-choice experiments (DCEs)-have become the most frequently applied approach in health care in recent years. Experimental design is an important stage in the development of such methods, but establishing a consensus on standards is hampered by lack of understanding of available techniques and software. This report builds on the previous ISPOR Conjoint Analysis Task Force Report: Conjoint Analysis Applications in Health-A Checklist: A Report of the ISPOR Good Research Practices for Conjoint Analysis Task Force. This report aims to assist researchers specifically in evaluating alternative approaches to experimental design, a difficult and important element of successful DCEs. While this report does not endorse any specific approach, it does provide a guide for choosing an approach that is appropriate for a particular study. In particular, it provides an overview of the role of experimental designs for the successful implementation of the DCE approach in health care studies, and it provides researchers with an introduction to constructing experimental designs on the basis of study objectives and the statistical model researchers have selected for the study. The report outlines the theoretical requirements for designs that identify choice-model preference parameters and summarizes and compares a number of available approaches for constructing experimental designs. The task-force leadership group met via bimonthly teleconferences and in person at ISPOR meetings in the United States and Europe. An international group of experimental-design experts was consulted during this process to discuss existing approaches for experimental design and to review the task force's draft reports. In addition, ISPOR members contributed to developing a consensus report by submitting written comments during the review process and oral comments during two forum presentations at the ISPOR 16th and 17th Annual International Meetings held in Baltimore (2011) and Washington, DC (2012). Copyright © 2013 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  13. New laparoscopic procedure for left-sided pancreatic cancer-artery-first approach laparoscopic RAMPS using 3D technique.

    PubMed

    Yamamoto, Michihiro; Zaima, Masazumi; Yamamoto, Hidekazu; Harada, Hideki; Kawamura, Junichiro; Yamada, Masahiro; Yazawa, Tekefumi; Kawasoe, Junya

    2017-12-02

    For left-sided pancreatic ductal adenocarcinoma (PDAC), radical antegrade modular pancreatosplenectomy (RAMPS) is a reasonable surgical approach for tumor-free margin resection and systemic lymph node clearance. In pancreaticoduodenectomy for PDAC, the superior mesenteric artery (SMA)-first approach (or the "artery-first approach") has become the standard procedure. With improvements in laparoscopic instruments and techniques, some surgeons attempted to apply laparoscopic RAMPS (L-RAMPS) for carefully selected patients with left-sided PDAC. However, owing to several technical difficulties in this procedure, its application remains uncommon. Moreover, the artery-first approach in L-RAMPS has not been reported. Here, we developed the artery-first approach L-RAMPS for left-sided PDAC and have presented the same in this report. Between June 2014 and July 2015, 16 patients with left-sided PDAC were referred to our division for pancreatic resection. The following technique was used for performing L-RAMPS on 3 of the 16 patients (19%). Six trocars were placed. After opening the omental bursa, only the middle segment of the pancreas was initially separated from both the left renal vein and the SMA. We termed this procedure as the "artery-first approach using a dome-shaped dorsomedial dissection (3D) technique." This 3D technique enabled the interruption of the entire arterial supply to the specimen while preserving the venous drainage through the splenic vein for preventing venous congestion. The technique also contributed to the early detection of no tumor infiltration into the SMA and the early determination of posterior dissection plane. After pancreatic neck transection, the splenic artery and vein were divided. Finally, the pancreatic tail and spleen were dissected in a right-to-left direction. All operations were completed without any intraoperative complications. The median blood loss and retrieved lymph node count were 75 mL and 37, respectively, which were superior to those reported by other previous studies on L-RAMPS. All resection margins were free of carcinoma. No severe postoperative complications were observed. The artery-first approach L-RAMPS using 3D technique is safe and feasible to perform. The significance of our proposed procedure is minimal blood loss and precise lymphadenectomy. Therefore, this novel technique may become the preferred treatment for left-sided PDAC in selected cases.

  14. ELECTROLYTIC SOLUTIONS. Annual Progress Report, May 1, 1962-June 1, 1963

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Braunstein, J.

    Results of investigations of the thermodynamics of association in molten salts and in concentrated aqueous electrolyte solutions are reported. Association constants of Pb(II) with chloride or bromide and of Cd(II) with chloride or bromide in molten mixtures of LiNC/sub 3/ and KNO/sub 3/ were measured potentiometrically at several temperatures and compared with previous results in mixtures of NaNO/sub 3/ and KNO/sub 3/. The anomalous'' solvent effect of lithium ion, reported previously for the association of Cd(II) with bromide was observed aiso for the other associations and a tentative explanation is suggested. The temperature dependence of the association constants was foundmore » to be in agreement with the quasi-lattice model. The association constant of Ag(I) with iodide in molten mixtures of NaNO/sub 3/ and KNO/sub 3/ was measured and compared with previous results in pure KNO/sub 3/. The solvent effect was consistent with the reciprocal coulomb effect.'' Techniques were developed, and preliminary results obtained for measuring association constants in the solvent system KNO/sub 3/--Ca(NO/sub 3/)/sub 2/ in order to investigate the effect of charge as well as size of solvent cation on association constants in molten salt solutions. The measurement of association constants in concentrated aqueous electrolyte solutions was continued. The association of Cd(II) with bromide in aqueous LiNC/sub 3/ was measured as part of a program to find a system that would lend itself to investigation over the range between anhydrous molten salt and aqueous electrolyte solution. Cells and electrodes were developed for investigating association constants in equimolar LiNO/sub 3/ -KNO/sub 3/ with controlled small water contents, and preliminary results are reported. (auth)« less

  15. 3D temporal subtraction on multislice CT images using nonlinear warping technique

    NASA Astrophysics Data System (ADS)

    Ishida, Takayuki; Katsuragawa, Shigehiko; Kawashita, Ikuo; Kim, Hyounseop; Itai, Yoshinori; Awai, Kazuo; Li, Qiang; Doi, Kunio

    2007-03-01

    The detection of very subtle lesions and/or lesions overlapped with vessels on CT images is a time consuming and difficult task for radiologists. In this study, we have developed a 3D temporal subtraction method to enhance interval changes between previous and current multislice CT images based on a nonlinear image warping technique. Our method provides a subtraction CT image which is obtained by subtraction of a previous CT image from a current CT image. Reduction of misregistration artifacts is important in the temporal subtraction method. Therefore, our computerized method includes global and local image matching techniques for accurate registration of current and previous CT images. For global image matching, we selected the corresponding previous section image for each current section image by using 2D cross-correlation between a blurred low-resolution current CT image and a blurred previous CT image. For local image matching, we applied the 3D template matching technique with translation and rotation of volumes of interests (VOIs) which were selected in the current and the previous CT images. The local shift vector for each VOI pair was determined when the cross-correlation value became the maximum in the 3D template matching. The local shift vectors at all voxels were determined by interpolation of shift vectors of VOIs, and then the previous CT image was nonlinearly warped according to the shift vector for each voxel. Finally, the warped previous CT image was subtracted from the current CT image. The 3D temporal subtraction method was applied to 19 clinical cases. The normal background structures such as vessels, ribs, and heart were removed without large misregistration artifacts. Thus, interval changes due to lung diseases were clearly enhanced as white shadows on subtraction CT images.

  16. Anatomy of Sodium Hypochlorite Accidents Involving Facial Ecchymosis – A Review

    PubMed Central

    Zhu, Wan-chun; Gyamfi, Jacqueline; Niu, Li-na; Schoeffel, G. John; Liu, Si-ying; Santarcangelo, Filippo; Khan, Sara; Tay, Kelvin C-Y.; Pashley, David H.; Tay, Franklin R.

    2013-01-01

    Objectives Root canal treatment forms an essential part of general dental practice. Sodium hypochlorite (NaOCl) is the most commonly used irrigant in endodontics due to its ability to dissolve organic soft tissues in the root canal system and its action as a potent antimicrobial agent. Although NaOCl accidents created by extrusion of the irrigant through root apices are relatively rare and are seldom life-threatening, they do create substantial morbidity when they occur. Methods To date, NaOCl accidents have only been published as isolated case reports. Although previous studies have attempted to summarise the symptoms involved in these case reports, there was no endeavor to analyse the distribution of soft tissue distribution in those reports. In this review, the anatomy of a classical NaOCl accident that involves facial swelling and ecchymosis is discussed. Results By summarising the facial manifestations presented in previous case reports, a novel hypothesis that involves intravenous infusion of extruded NaOCl into the facial vein via non-collapsible venous sinusoids within the cancellous bone is presented. Conclusions Understanding the mechanism involved in precipitating a classic NaOCl accident will enable the profession to make the best decision regarding the choice of irrigant delivery techniques in root canal débridement, and for manufacturers to design and improve their irrigation systems to achieve maximum safety and efficient cleanliness of the root canal system. PMID:23994710

  17. Anatomy of sodium hypochlorite accidents involving facial ecchymosis - a review.

    PubMed

    Zhu, Wan-chun; Gyamfi, Jacqueline; Niu, Li-na; Schoeffel, G John; Liu, Si-ying; Santarcangelo, Filippo; Khan, Sara; Tay, Kelvin C-Y; Pashley, David H; Tay, Franklin R

    2013-11-01

    Root canal treatment forms an essential part of general dental practice. Sodium hypochlorite (NaOCl) is the most commonly used irrigant in endodontics due to its ability to dissolve organic soft tissues in the root canal system and its action as a potent antimicrobial agent. Although NaOCl accidents created by extrusion of the irrigant through root apices are relatively rare and are seldom life-threatening, they do create substantial morbidity when they occur. To date, NaOCl accidents have only been published as isolated case reports. Although previous studies have attempted to summarise the symptoms involved in these case reports, there was no endeavour to analyse the distribution of soft tissue distribution in those reports. In this review, the anatomy of a classical NaOCl accident that involves facial swelling and ecchymosis is discussed. By summarising the facial manifestations presented in previous case reports, a novel hypothesis that involves intravenous infusion of extruded NaOCl into the facial vein via non-collapsible venous sinusoids within the cancellous bone is presented. Understanding the mechanism involved in precipitating a classic NaOCl accident will enable the profession to make the best decision regarding the choice of irrigant delivery techniques in root canal débridement, and for manufacturers to design and improve their irrigation systems to achieve maximum safety and efficient cleanliness of the root canal system. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Histological analysis on the medieval mummy in Korea.

    PubMed

    Shin, Dong Hoon; Youn, Minyoung; Chang, Byung Soo

    2003-11-26

    Recently, there have been some reports on the mummies from the medieval tombs in Korea, which were not made on purpose. Although these mummies could be an invaluable source for the studies on the physical state of medieval Koreans, there were not any reports on this subject until now. In this study, we first tried to investigate the various tissues using light- and electron-microscopic techniques. In the organs we have examined, even though the collagen fibers were profusely found within all of them, some types of cells, such as red blood cells, chondrocytes, hepatocyte and muscle cells, were also visible in various tissues. The histological characteristics of the current case seemed to be well matched with the previous study in general even though there were also somewhat different findings from the previous reports on the mummies. Although the cause of the mummification in Korea was not completely explained, we think that the cause in this case could be correlated with cultural aspects--not with natural conditions--because the mummies were only found in cases where the lime-soil barrier was maintained until their discovery, and which separated the inner space of the coffins from the outer space. As similar cases are frequently reported nowadays, invaluable data on the physical status of the medieval Koreans could be attainable if systemic investigation could be performed on similar cases which are found in the future.

  19. Slab fractures of the third tarsal bone: Minimally invasive repair using a single 3.5 mm cortex screw placed in lag fashion in 17 Thoroughbred racehorses.

    PubMed

    Barker, W H J; Wright, I M

    2017-03-01

    A technique for minimally invasive repair of slab fractures of the third tarsal bone has not previously been reported. Results of third tarsal bone slab fracture repair in Thoroughbred racehorses are lacking. To report the outcomes of repair of uniplanar frontal slab factures of the third tarsal bone using a single 3.5 mm cortex screw in lag fashion. Retrospective case series. Case records of horses that had undergone this procedure were reviewed. Seventeen horses underwent surgery. Eighteen percent of cases had wedge shaped third tarsal bones. A point midway between the long and lateral digital extensor tendons and centrodistal and tarsometatarsal joints created a suitable entry site for implants. The fracture location, configuration and curvature of the third tarsal bone and associated joints requires a dorsolateral proximal-plantaromedial distal trajectory for the screw, which was determined by preplaced needles. There were no complications and fractures healed in all cases at 4-6 months post surgery. Seventy-nine percent of horses returned to racing and, at the time of reporting, 3 are in post operative rehabilitation programmes. The technique reported provides a safe, appropriate and repeatable means of repairing slab fractures of the third tarsal bone. Surgical repair is a viable alternative to conservative management. © 2016 EVJ Ltd.

  20. Direct optical imaging of nanoscale internal organization of polymer films

    NASA Astrophysics Data System (ADS)

    Suran, Swathi; Varma, Manoj

    2018-02-01

    Owing to its sensitivity and precise control at the nanoscale, polyelectrolytes have been immensely used to modify surfaces. Polyelectrolyte multilayers are generally water made and are easy to fabricate on any surface by the layer-by-layer (LbL) self-assembly process due to electrostatic interactions. Polyelectrolyte multilayers or PEMs can be assembled to form ultrathin membranes which can have potential applications in water filtration and desalination [1-3]. Hydration in PEMs is a consequence of both the bulk and surface phenomenon [4-7]. Bulk behavior of polymer membranes are well understood. Several techniques including reflectivity and contact angle measurements were used to measure the hydration in the bulk of polymer membranes [4, 8]. On the other hand their internal organization at the molecular level which can have a profound contribution in the transport mechanism, are not understood well. Previously, we engineered a technique, which we refer to as Bright-field Nanoscopy, which allows nanoscale optical imaging using local heterogeneities in a water-soluble germanium (Ge) thin film ( 25 nm thick) deposited on gold [8]. We use this technique to study the water transport in PEMs. It is understood that the surface charge and outer layers of the PEMs play a significant role in water transport through polymers [9-11]. This well-known `odd-even' effect arising on having different surface termination of the PEMs was optically observed with a spatial resolution unlike any other reported previously [12]. In this communication, we report that on increasing the etchant's concentration, one can control the lateral etching of the Ge film. This allowed the visualization of the nanoscale internal organization in the PEMs. Knowledge of the internal structure would allow one to engineer polymer membranes specific to applications such as drug delivering capsules, ion transport membranes and barriers etc. We also demonstrate a mathematical model involving a surface permeability term which captures the experimentally observed odd-even effect.

  1. High resolution spectroscopy of the 12Lambda B hypernucleus produced by the (e,e'K+) reaction.

    PubMed

    Miyoshi, T; Sarsour, M; Yuan, L; Zhu, X; Ahmidouch, A; Ambrozewicz, P; Androic, D; Angelescu, T; Asaturyan, R; Avery, S; Baker, O K; Bertovic, I; Breuer, H; Carlini, R; Cha, J; Chrien, R; Christy, M; Cole, L; Danagoulian, S; Dehnhard, D; Elaasar, M; Empl, A; Ent, R; Fenker, H; Fujii, Y; Furic, M; Gan, L; Garrow, K; Gasparian, A; Gueye, P; Harvey, M; Hashimoto, O; Hinton, W; Hu, B; Hungerford, E; Jackson, C; Johnston, K; Juengst, H; Keppel, C; Lan, K; Liang, Y; Likhachev, V P; Liu, J H; Mack, D; Margaryan, A; Markowitz, P; Martoff, J; Mkrtchyan, H; Nakamura, S N; Petkovic, T; Reinhold, J; Roche, J; Sato, Y; Sawafta, R; Simicevic, N; Smith, G; Stepanyan, S; Tadevosyan, V; Takahashi, T; Tanida, K; Tang, L; Ukai, M; Uzzle, A; Vulcan, W; Wells, S; Wood, S; Xu, G; Yamaguchi, H; Yan, C

    2003-06-13

    High-energy, cw electron beams at new accelerator facilities allow electromagnetic production and precision study of hypernuclear structure, and we report here on the first experiment demonstrating the potential of the (e,e'K+) reaction for hypernuclear spectroscopy. This experiment is also the first to take advantage of the enhanced virtual photon flux available when electrons are scattered at approximately zero degrees. The observed energy resolution was found to be approximately 900 keV for the (12)(Lambda)B spectrum, and is substantially better than any previous hypernuclear experiment using magnetic spectrometers. The positions of the major excitations are found to be in agreement with a theoretical prediction and with a previous binding energy measurement, but additional structure is also observed in the core excited region, underlining the future promise of this technique.

  2. Quantitative force measurements in liquid using frequency modulation atomic force microscopy

    NASA Astrophysics Data System (ADS)

    Uchihashi, Takayuki; Higgins, Michael J.; Yasuda, Satoshi; Jarvis, Suzanne P.; Akita, Seiji; Nakayama, Yoshikazu; Sader, John E.

    2004-10-01

    The measurement of short-range forces with the atomic force microscope (AFM) typically requires implementation of dynamic techniques to maintain sensitivity and stability. While frequency modulation atomic force microscopy (FM-AFM) is used widely for high-resolution imaging and quantitative force measurements in vacuum, quantitative force measurements using FM-AFM in liquids have proven elusive. Here we demonstrate that the formalism derived for operation in vacuum can also be used in liquids, provided certain modifications are implemented. To facilitate comparison with previous measurements taken using surface forces apparatus, we choose a model system (octamethylcyclotetrasiloxane) that is known to exhibit short-ranged structural ordering when confined between two surfaces. Force measurements obtained are found to be in excellent agreement with previously reported results. This study therefore establishes FM-AFM as a powerful tool for the quantitative measurement of forces in liquid.

  3. The EPR study of Mn(2+) ion doped DADT single crystal produced under high pressure and temperature.

    PubMed

    Ceylan, Ümit; Tapramaz, Recep

    2016-01-05

    An EPR study on Cu(2+) and VO(2+) doped di ammonium d-tartrate single crystals has been reported in previous papers, but the same host did not accept Mn(2+) ion at the same reaction conditions in previous trials. In this study EPR study of Mn(2+) ion doped di ammonium d tartrate single crystal, (DADT) [(NH4)2C4H4O6], produced in a reactor under high pressure and high temperature. The electronic transitions were determined by the optical absorption spectrum. Hyperfine splitting and g values of the Mn(2+) ion forming a complex in the lattice were measured from experimental spectra and spin-spin dipolar splitting parameters D and E were found by the spectrum simulation techniques. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Preparation and characterization of the magnetic superconductor EuSr2RuCu2O8-δ (RuEu-1212) by partial melting

    NASA Astrophysics Data System (ADS)

    Yamaki, K.; Kitagawa, N.; Funahashi, S.; Bamba, Y.; Irie, A.

    2018-07-01

    In this study, fine single crystals of the magnetic superconductor EuSr2RuCu2O8-δ (RuEu-1212) were successfully prepared using the partial melting technique. The obtained single crystals had a cubic shape, which coincides with the results of previous studies of RuGd-1212 single crystals. The single crystals had a typical length of 20-30 μm and the diffraction pattern observed from a sample prepared by partial melting was consistent with patterns of previously reported polycrystalline RuEu-1212 samples. A sample subjected to prolonged sintering, which consisted of a large number of combined micro single crystals prepared by partial melting, exhibited a superconducting transition with Tc-onset of 30.9 K and Tc-zero of 10.5 K.

  5. Airline return-on-investment model for technology evaluation. [computer program to measure economic value of advanced technology applied to passenger aircraft

    NASA Technical Reports Server (NTRS)

    1974-01-01

    This report presents the derivation, description, and operating instructions for a computer program (TEKVAL) which measures the economic value of advanced technology features applied to long range commercial passenger aircraft. The program consists of three modules; and airplane sizing routine, a direct operating cost routine, and an airline return-on-investment routine. These modules are linked such that they may be operated sequentially or individually, with one routine generating the input for the next or with the option of externally specifying the input for either of the economic routines. A very simple airplane sizing technique was previously developed, based on the Brequet range equation. For this program, that sizing technique has been greatly expanded and combined with the formerly separate DOC and ROI programs to produce TEKVAL.

  6. A modification of Chopart's amputation with ankle and subtalar arthrodesis by using an intramedullary nail.

    PubMed

    DeGere, Michael W; Grady, John F

    2005-01-01

    This study reports on 7 patients who underwent a new technique for Chopart amputation that includes ankle and subtalar arthrodesis using an intramedullary nail. This method affords rigid control to the rearfoot and appears to avoid the most common complications historically associated with Chopart amputations. All 6 surviving patients achieved successful outcomes within 1 year of their surgery. All are community ambulators who are able to walk short distances within the home without a prosthesis. One patient, who had undergone a previous vascular bypass, died in the early postoperative period after developing an infection that required an above-knee amputation. A second patient developed an infection that resolved with intravenous antibiotics. This new technique reintroduces the Chopart-level amputation as a valuable intermediate between the transmetatarsal and below-knee amputation levels.

  7. Delayed Infective Endocarditis with Mycotic Aneurysm Rupture below the Mechanical Valved Conduit after the Bentall Procedure.

    PubMed

    Chen, Mei-Ling; Chen, Michael Y; Yin, Wei-Hsian; Wei, Jeng; Wang, Ji-Hung

    2014-07-01

    The Bentall procedure is the gold standard for treating aortic dissection complicated with valvular and ascending aorta disease. Recent results for this procedure have been excellent; nearly 100% of patients remain free of infective endocarditis in long-term follow-up. We report a case of delayed Streptococcus agalactiae infective endocarditis complicated by mycotic aneurysm in a man who had undergone the Bentall procedure with a mechanical valve conduit 15 years previously. The mycotic aneurysm was located in the remnant aortic root, below the mechanical valve conduit, and later ruptured into the right atrium. The patient was treated conservatively and survived the acute period. Later, the aortic root defect was repaired successfully by means of a hybrid technique using a Amplatzer duct occluder. Amplatzer duct occluder; Aortic dissection; Bentall technique; Infective endocarditis; Mycotic aneurysm.

  8. Navigation bronchoscopy for diagnosis and small nodule location

    PubMed Central

    Muñoz-Largacha, Juan A.; Litle, Virginia R.

    2017-01-01

    Lung cancer continues to be the most common cause of cancer death. Screening programs for high risk patients with the use of low-dose computed tomography (CT) has led to the identification of small lung lesions that were difficult to identify using previous imaging modalities. Electromagnetic navigational bronchoscopy (ENB) is a novel technique that has shown to be of great utility during the evaluation of small, peripheral lesions, that would otherwise be challenging to evaluate with conventional bronchoscopy. The diagnostic yield of navigational bronchoscopy however is highly variable, with reports ranging from 59% to 94%. This variability suggests that well-defined selection criteria and standardized protocols for the use of ENB are lacking. Despite this variability, we believe that this technique is a useful tool evaluating small peripheral lung lesions when patients are properly selected. PMID:28446971

  9. [Brachytherapy for head and neck cancers].

    PubMed

    Peiffert, D; Coche-Dequéant, B; Lapeyre, M; Renard, S

    2018-05-29

    The main indications of the brachytherapy of head and neck cancers are the limited tumours of the lip, the nose, the oral cavity and the oropharynx. Nasopharynx tumours are nowadays treated by intensity-modulated radiotherapy. This technique can be exclusive, associated with external radiotherapy or postoperative. It can also be a salvage treatment for the second primaries in previously irradiated areas. If the low dose rate brachytherapy rules remain the reference, the pulse dose rate technique allows the prescription of the dose rate and the optimisation of the dose distribution. Results of high dose rate brachytherapy are now published. This paper reports the recommendations of the Gec-ESTRO, published in 2017, and takes into account the data of the historical low dose rate series, and is upgraded with the pulsed-dose rate and high dose rate series. Copyright © 2018. Published by Elsevier SAS.

  10. Techniques used to search for a permanent electric dipole moment of the 199Hg atom and the implications for CP violation

    NASA Astrophysics Data System (ADS)

    Swallows, M. D.; Loftus, T. H.; Griffith, W. C.; Heckel, B. R.; Fortson, E. N.; Romalis, M. V.

    2013-01-01

    We discuss in detail the search for a permanent electric dipole moment (EDM) of the 199Hg atom reported by Griffith [Phys. Rev. Lett.PRLTAO0031-900710.1103/PhysRevLett.102.101601 102, 101601 (2009)]. The upper bound, d(199Hg)<3.1×10-29 e cm (95% C.L.), is a factor of 7 improvement over the best previous EDM limit for 199Hg, provides the most sensitive probe to date for EDMs in diamagnetic atoms, and sets new limits on time-reversal symmetry violation in extensions to the standard model. This paper provides extensive discussion of the techniques used to search for the 199Hg EDM and the implications of the new 199Hg EDM limit for CP violation in elementary particle interactions.

  11. Fe Oxides on Ag Surfaces: Structure and Reactivity

    DOE PAGES

    Shipilin, M.; Lundgren, E.; Gustafson, J.; ...

    2016-09-09

    One layer thick iron oxide films are attractive from both applied and fundamental science perspectives. The structural and chemical properties of these systems can be tuned by changing the substrate, making them promising materials for heterogeneous catalysis. In the present work, we investigate the structure of FeO(111) monolayer films grown on Ag(100) and Ag(111) substrates by means of microscopy and diffraction techniques and compare it with the structure of FeO(111) grown on other substrates reported in literature. We also study the NO adsorption properties of FeO(111)/Ag(100) and FeO(111)/Ag(111) systems utilizing different spectroscopic techniques. Finally, we discuss similarities and differences inmore » the data obtained from adsorption experiments and compare it with previous results for FeO(111)/Pt(111).« less

  12. Fe Oxides on Ag Surfaces: Structure and Reactivity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shipilin, M.; Lundgren, E.; Gustafson, J.

    One layer thick iron oxide films are attractive from both applied and fundamental science perspectives. The structural and chemical properties of these systems can be tuned by changing the substrate, making them promising materials for heterogeneous catalysis. In the present work, we investigate the structure of FeO(111) monolayer films grown on Ag(100) and Ag(111) substrates by means of microscopy and diffraction techniques and compare it with the structure of FeO(111) grown on other substrates reported in literature. We also study the NO adsorption properties of FeO(111)/Ag(100) and FeO(111)/Ag(111) systems utilizing different spectroscopic techniques. Finally, we discuss similarities and differences inmore » the data obtained from adsorption experiments and compare it with previous results for FeO(111)/Pt(111).« less

  13. Measurement of θ 13 in Double Chooz using neutron captures on hydrogen with novel background rejection techniques

    DOE PAGES

    Abe, Y.; Appel, S.; Abrahão, T.; ...

    2016-01-27

    We observed a measurement of the Double Chooz collaboration and the neutrino mixing angle θ 13 using reactormore » $$\\bar{v}$$ e via the inverse beta decay reaction in which the neutron is captured on hydrogen. Our measurement is based on 462.72 live days data, approximately twice as much data as in the previous such analysis, collected with a detector positioned at an average distance of 1050 m from two reactor cores. Several novel techniques have been developed to achieve significant reductions of the backgrounds and systematic uncertainties. Accidental coincidences, the dominant background in this analysis, are suppressed by more than an order of magnitude with respect to our previous publication by a multi-variate analysis. Furthermore, these improvements demonstrate the capability of precise measurement of reactor $$\\bar{v}$$ e without gadolinium loading. Spectral distortions from the $$\\bar{v}$$ e reactor flux predictions previously reported with the neutron capture on gadolinium events are confirmed in the independent data sample presented here. A value of sin 2 2θ 13= 0.095 0.039 +0.038 (stat+syst) is obtained from a fit to the observed event rate as a function of the reactor power, a method insensitive to the energy spectrum shape. A simultaneous fit of the hydrogen capture events and of the gadolinium capture events yields a measurement of sin 2 2θ 13 = 0.088 ± 0.033(stat+syst).« less

  14. Management of Laryngoceles by Transoral Robotic Approach.

    PubMed

    Kayhan, Fatma Tülin; Güneş, Selçuk; Koç, Arzu Karaman; Yiğider, Ayşe Pelin; Kaya, Kamil Hakan

    2016-06-01

    Laryngoceles are air-filled sacs which communicate with the laryngeal lumen. When filled with mucus or pus, they are called laryngomucoceles and laryngopyoceles, respectively. Transoral robotic surgery (TORS) is a new and remarkable technique that expands its usefullness in otorhinolaryngology. Conventional treatments for laryngoceles were previously performed using external approaches, with aesthetically unfavorable and less function-sparing results. Transoral laser microsurgical approaches for laryngoceles were seldom reported. It is aimed to present authors' clinical experience on laryngocele management with TORS which is a rather new technique. A retrospective patient serial. Patients were evaluated for demographic data, type of lesion, reasons for hospital admittance, complaint duration, and previous surgery. Robotic surgery panel including anesthesia time, duration of surgery, need for tracheotomy, postoperative care, follow-up, and recurrence rates were also summarized. Six men (mean age 51.7 years; range 41-62) with laryngoceles underwent successful TORS. Dyspnea and hoarseness were the main complaints. Two patients had undergone previous laryngeal surgery due to laryngeal cancer, with no recurrence of malignancy at admittance for laryngocele. Three had simple laryngocele, 2 had laryngomucocele, and 1 had laryngopyocele. No laryngoceles recurred and no complication such as dysphonia or prolonged dysphagia occurred. Transoral robotic surgery was found superior in safety, technical feasibility and curative effectiveness, when compared with classical methods, especially due to absence of skin incisions. Surgical modalities for laryngocele excision should be directed toward a curative target including cosmetic and functional success, technical achievability, and surgically curative methods. Transoral robotic surgery provided all these features.

  15. Analysis of Reasons for Failure of Surgery for Degenerative Disease of Lumbar Spine.

    PubMed

    Baranowska, Alicja; Baranowska, Joanna; Baranowski, Paweł

    2016-03-23

    In the aging society, there is a growing number of patients with advanced degenerative disease of the spine. These patients frequently require surgical treatment. This paper aims to analyse the reasons for failure of surgery for degenerative disease of the lumbar spine. Histories of patients operated on by one group of surgeons in the Neuroorthopaedic Department of "STOCER" in 2014 and 2015 due to degenerative disease of the lumbar spine were analysed retrospectively. Out of the cohort, patients who had undergone a revision surgery were selected for the study and divided into two groups: group A (60) of patients previously operated on in another centre and group B (47) of patients previously operated on in "STOCER". The reasons for failure of the surgery were analysed in detail based on history, physical examination, imaging studies and surgery reports. Surgery was performed in 601 patients, of whom 107 patients had been previously operated on. The most frequent reasons for revision surgery of the same motor segment were recurrent disc herniation, inadequate decompression and inappropriate surgical technique. In the group of patients who had implants inserted to stabilise the spine, the revision surgery in most cases was due to adjacent segment disease. Use of implants and spinal fusion is always associated with a risk of complications and is frequently independent of the surgeon. 2. In order to reduce the rate of revision surgeries, it is important to perform complete decompression and select an adequate surgical technique.

  16. Treatment of chronic Achilles tendon rupture by shortening suture and free sural triceps aponeurosis graft.

    PubMed

    Khiami, F; Di Schino, M; Sariali, E; Cao, D; Rolland, E; Catonné, Y

    2013-09-01

    The Bosworth technique is old but still widely used. It involves problems of precisely determining the length of the Achilles tendon and of a volume effect in the turndown area. A new reconstruction technique is assessed, based on free sural triceps aponeurosis transfer without turndown, associated to tendon shortening suture. Twenty-three patients were assessed by AOFAS score and clinical examination (plus MRI in 14 cases) at a mean 24.5 months' follow-up. Mean age was 52.1 years. Mean pre-operative AOFAS score was 63.6/100. Mean postoperative AOFAS score was 96.1. Mean graft length was 7.5 cm. Surgical revision was required for one case of postoperative infection. Twelve patients resumed leisure sports at their previous level by a mean 9.4 ± 2 months; three competitive sportsmen resumed sport at their previous level by a mean 7.6 months. None were dissatisfied or disappointed with their operation. MRI performed at 1 year found increased tendon volume without abnormality in 57% of cases; 43% showed abnormal images. Functional results were comparable to literature reports. It can be difficult to determine Achilles length for the Bosworth technique: this is made easier by conserving a fibrous support of a length determined with reference to the healthy side. The technique avoids aponeurosis turndown, and thus avoids the problem of plasty volume effect. The two cases of cutaneous complication occurred in the two most elderly patients, raising the question of the indications for reconstructive surgery in the elderly. The abnormalities found on MRI concerned scar tissue remodeling in patients with good or excellent clinical results. Level IV, retrospective study. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  17. A highly efficient bead extraction technique with low bead number for digital microfluidic immunoassay

    PubMed Central

    Tsai, Po-Yen; Lee, I-Chin; Hsu, Hsin-Yun; Huang, Hong-Yuan; Fan, Shih-Kang; Liu, Cheng-Hsien

    2016-01-01

    Here, we describe a technique to manipulate a low number of beads to achieve high washing efficiency with zero bead loss in the washing process of a digital microfluidic (DMF) immunoassay. Previously, two magnetic bead extraction methods were reported in the DMF platform: (1) single-side electrowetting method and (2) double-side electrowetting method. The first approach could provide high washing efficiency, but it required a large number of beads. The second approach could reduce the required number of beads, but it was inefficient where multiple washes were required. More importantly, bead loss during the washing process was unavoidable in both methods. Here, an improved double-side electrowetting method is proposed for bead extraction by utilizing a series of unequal electrodes. It is shown that, with proper electrode size ratio, only one wash step is required to achieve 98% washing rate without any bead loss at bead number less than 100 in a droplet. It allows using only about 25 magnetic beads in DMF immunoassay to increase the number of captured analytes on each bead effectively. In our human soluble tumor necrosis factor receptor I (sTNF-RI) model immunoassay, the experimental results show that, comparing to our previous results without using the proposed bead extraction technique, the immunoassay with low bead number significantly enhances the fluorescence signal to provide a better limit of detection (3.14 pg/ml) with smaller reagent volumes (200 nl) and shorter analysis time (<1 h). This improved bead extraction technique not only can be used in the DMF immunoassay but also has great potential to be used in any other bead-based DMF systems for different applications. PMID:26858807

  18. The Effects of Tai Chi Intervention on Healthy Elderly by Means of Neuroimaging and EEG: A Systematic Review.

    PubMed

    Pan, Zhujun; Su, Xiwen; Fang, Qun; Hou, Lijuan; Lee, Younghan; Chen, Chih C; Lamberth, John; Kim, Mi-Lyang

    2018-01-01

    Aging is a process associated with a decline in cognitive and motor functions, which can be attributed to neurological changes in the brain. Tai Chi, a multimodal mind-body exercise, can be practiced by people across all ages. Previous research identified effects of Tai Chi practice on delaying cognitive and motor degeneration. Benefits in behavioral performance included improved fine and gross motor skills, postural control, muscle strength, and so forth. Neural plasticity remained in the aging brain implies that Tai Chi-associated benefits may not be limited to the behavioral level. Instead, neurological changes in the human brain play a significant role in corresponding to the behavioral improvement. However, previous studies mainly focused on the effects of behavioral performance, leaving neurological changes largely unknown. This systematic review summarized extant studies that used brain imaging techniques and EEG to examine the effects of Tai Chi on older adults. Eleven articles were eligible for the final review. Three neuroimaging techniques including fMRI ( N = 6), EEG ( N = 4), and MRI ( N = 1), were employed for different study interests. Significant changes were reported on subjects' cortical thickness, functional connectivity and homogeneity of the brain, and executive network neural function after Tai Chi intervention. The findings suggested that Tai Chi intervention give rise to beneficial neurological changes in the human brain. Future research should develop valid and convincing study design by applying neuroimaging techniques to detect effects of Tai Chi intervention on the central nervous system of older adults. By integrating neuroimaging techniques into randomized controlled trials involved with Tai Chi intervention, researchers can extend the current research focus from behavioral domain to neurological level.

  19. DIAGNOSIS OF ORF IN WEST AFRICAN DWARF GOATS IN UYO, AKWA IBOM STATE, NIGERIA

    PubMed Central

    Adedeji, Adeyinka Jeremy; Maurice, Nanven Abraham; Wungak, Yiltawe Simwal; Adole, Jolly Amoche; Chima, Nneka Chineze; Woma, Timothy Yusufu; Chukwuedo, Anthony Amechi; DavidShamaki, and

    2017-01-01

    Background: Sixty (60) male West African Dwarf goats were reported with clinical signs of enlarged lymph nodes, scabs on the mouth, nose and ears. Two of the goats died and post mortem examination reveals enlarged submandibular lymph nodes and vesicular lesions on the tongue. Clinical diagnosis of Orf has been reported in Nigeria but this report is the confirmatory diagnosis of Orf in a suspected outbreak in an experimental farm in Uyo, Akwa Ibom State, Nigeria using molecular techniques. Materials and Methods: Scabs, spleen and lymph node samples from goats suspected to have died from Orf were collected, transported on ice to the laboratory and homogenized. The DNA was extracted using QIAmp DNA minikit (Qiagen) according to the manufacturer’s instructions. Orf virus (ORFV) was amplified using published ORFVspecific primers by PCR. Results: Morbidity and mortality were 100% and 3.3% respectively, while ORFV was detected by PCR. Diagnosis of Orf was confirmed based on clinical signs of enlarged lymph nodes, scabs on the mouth, nose and ears, necropsy findings of enlarged submandibular lymph nodes and vesicular lesions on the tongue and PCR results. Conclusion: This may be the first report of molecular diagnosis of Orf in Nigeria. The 100% morbidity and 3.3% mortality rate is higher than previously reported thus Orf is becoming of greater economic importance than previously thought. It is therefore recommended that routine laboratory diagnosis of Orf be carried nationwide to determine the prevalence of Orf in Nigeria. PMID:28670645

  20. A Symptom-Focused Hypnotic Approach to Accessing and Processing Previously Repressed/Dissociated Memories.

    ERIC Educational Resources Information Center

    Ratican, Kathleen L.

    1996-01-01

    The kinesthetic track back technique accesses the origins of current symptoms and may uncover previously repressed/dissociated material, if such material exists in the client's unconscious mind, is relevant to the symptoms, and is ready to be processed consciously. Case examples are given to illustrate proper use of this technique. (LSR)

  1. Paced respiration with end-expiration technique offers superior BOLD signal repeatability for breath-hold studies.

    PubMed

    Scouten, A; Schwarzbauer, C

    2008-11-01

    As a simple, non-invasive method of blood oxygenation level-dependent (BOLD) signal calibration, the breath-hold task offers considerable potential for the quantification of neuronal activity from functional magnetic resonance imaging (fMRI) measurements. With an aim to improve the precision of this calibration method, the impact of respiratory rate control on the BOLD signal achieved with the breath-hold task was investigated. In addition to self-paced breathing, three different computer-paced breathing rates were imposed during the periods between end-expiration breath-hold blocks. The resulting BOLD signal timecourses and statistical activation maps were compared in eleven healthy human subjects. Results indicate that computer-paced respiration produces a larger peak BOLD signal increase with breath-hold than self-paced breathing, in addition to lower variability between trials. This is due to the more significant post-breath-hold signal undershoot present in self-paced runs, a characteristic which confounds the definition of baseline and is difficult to accurately model. Interestingly, the specific respiratory rate imposed between breath-hold periods generally does not have a statistically significant impact on the BOLD signal change. This result can be explained by previous reports of humans adjusting their inhalation depth to compensate for changes in rate, with the end-goal of maintaining homeostatic ventilation. The advantage of using end-expiration relative to end-inspiration breath-hold is apparent in view of the high repeatability of the BOLD signal in the present study, which does not suffer from the previously reported high variability associated with uncontrolled inspiration depth when using the end-inspiration technique.

  2. Synthesis of a mixed-valent tin nitride and considerations of its possible crystal structures

    DOE PAGES

    Caskey, Christopher M.; Holder, Aaron; Shulda, Sarah; ...

    2016-04-12

    Recent advances in theoretical structure prediction methods and high-throughput computational techniques are revolutionizing experimental discovery of the thermodynamically stable inorganic materials. Metastable materials represent a new frontier for these studies, since even simple binary non-ground state compounds of common elements may be awaiting discovery. However, there are significant research challenges related to non-equilibrium thin film synthesis and crystal structure predictions, such as small strained crystals in the experimental samples and energy minimization based theoretical algorithms. Here, we report on experimental synthesis and characterization, as well as theoretical first-principles calculations of a previously unreported mixed-valent binary tin nitride. Thin film experimentsmore » indicate that this novel material is N-deficient SnN with tin in the mixed ii/iv valence state and a small low-symmetry unit cell. Theoretical calculations suggest that the most likely crystal structure has the space group 2 (SG2) related to the distorted delafossite (SG166), which is nearly 0.1 eV/atom above the ground state SnN polymorph. Furthermore, this observation is rationalized by the structural similarity of the SnN distorted delafossite to the chemically related Sn 3N 4 spinel compound, which provides a fresh scientific insight into the reasons for growth of polymorphs of metastable materials. In addition to reporting on the discovery of the simple binary SnN compound, this paper illustrates a possible way of combining a wide range of advanced characterization techniques with the first-principle property calculation methods, to elucidate the most likely crystal structure of the previously unreported metastable materials.« less

  3. Implantable Subcutaneous Venous Access Devices: Is Port Fixation Necessary? A Review of 534 Cases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McNulty, Nancy J., E-mail: nancy.mcnulty@hitchcock.org; Perrich, Kiley D.; Silas, Anne M.

    2010-08-15

    Conventional surgical technique of subcutaneous venous port placement describes dissection of the port pocket to the pectoralis fascia and suture fixation of the port to the fascia to prevent inversion of the device within the pocket. This investigation addresses the necessity of that step. Between October 8, 2004 and October 19, 2007, 558 subcutaneous chest ports were placed at our institution; 24 cases were excluded from this study. We performed a retrospective review of the remaining 534 ports, which were placed using standard surgical technique with the exception that none were sutured into the pocket. Mean duration of port use,more » total number of port days, indications for removal, and complications were recorded and compared with the literature. Mean duration of port use was 341 days (182,235 total port days, range 1-1279). One port inversion/flip occurred, which resulted in malfunction and necessitated port revision (0.2%). Other complications necessitating port removal included infection 26 (5%), thrombosis n = 2 (<1%), catheter fracture/pinch n = 1 (<1%), pain n = 2 (<1%), and skin erosion n = 3 (1%). There were two arrhythmias at the time of placement; neither required port removal. The overall complication rate was 7%. The 0.2% incidence of port inversion we report is concordant with that previously published, although many previous reports do not specify if suture fixation of the port was performed. Suture fixation of the port, in our experience, is not routinely necessary and may negatively impact port removal.« less

  4. Dancing in the Dark: New Brown Dwarf Binaries from Kernel Phase Interferometry

    NASA Astrophysics Data System (ADS)

    Pope, Benjamin; Martinache, Frantz; Tuthill, Peter

    2013-04-01

    This paper revisits a sample of ultracool dwarfs in the solar neighborhood previously observed with the Hubble Space Telescope's NICMOS NIC1 instrument. We have applied a novel high angular resolution data analysis technique based on the extraction and fitting of kernel phases to archival data. This was found to deliver a dramatic improvement over earlier analysis methods, permitting a search for companions down to projected separations of ~1 AU on NIC1 snapshot images. We reveal five new close binary candidates and present revised astrometry on previously known binaries, all of which were recovered with the technique. The new candidate binaries have sufficiently close separation to determine dynamical masses in a short-term observing campaign. We also present four marginal detections of objects which may be very close binaries or high-contrast companions. Including only confident detections within 19 pc, we report a binary fraction of at least \\epsilon _b = 17.2^{+5.7}_{-3.7} %. The results reported here provide new insights into the population of nearby ultracool binaries, while also offering an incisive case study of the benefits conferred by the kernel phase approach in the recovery of companions within a few resolution elements of the point-spread function core. Based on observations performed with the NASA/ESA Hubble Space Telescope. The Hubble observations are associated with proposal ID 10143 and 10879 and were obtained at the Space Telescope Science Institute, which is operated by the Association of Universities for Research in Astronomy, Inc., under NASA contract NAS 5-26555.

  5. Synthesis of a mixed-valent tin nitride and considerations of its possible crystal structures

    NASA Astrophysics Data System (ADS)

    Caskey, Christopher M.; Holder, Aaron; Shulda, Sarah; Christensen, Steven T.; Diercks, David; Schwartz, Craig P.; Biagioni, David; Nordlund, Dennis; Kukliansky, Alon; Natan, Amir; Prendergast, David; Orvananos, Bernardo; Sun, Wenhao; Zhang, Xiuwen; Ceder, Gerbrand; Ginley, David S.; Tumas, William; Perkins, John D.; Stevanovic, Vladan; Pylypenko, Svitlana; Lany, Stephan; Richards, Ryan M.; Zakutayev, Andriy

    2016-04-01

    Recent advances in theoretical structure prediction methods and high-throughput computational techniques are revolutionizing experimental discovery of the thermodynamically stable inorganic materials. Metastable materials represent a new frontier for these studies, since even simple binary non-ground state compounds of common elements may be awaiting discovery. However, there are significant research challenges related to non-equilibrium thin film synthesis and crystal structure predictions, such as small strained crystals in the experimental samples and energy minimization based theoretical algorithms. Here, we report on experimental synthesis and characterization, as well as theoretical first-principles calculations of a previously unreported mixed-valent binary tin nitride. Thin film experiments indicate that this novel material is N-deficient SnN with tin in the mixed ii/iv valence state and a small low-symmetry unit cell. Theoretical calculations suggest that the most likely crystal structure has the space group 2 (SG2) related to the distorted delafossite (SG166), which is nearly 0.1 eV/atom above the ground state SnN polymorph. This observation is rationalized by the structural similarity of the SnN distorted delafossite to the chemically related Sn3N4 spinel compound, which provides a fresh scientific insight into the reasons for growth of polymorphs of metastable materials. In addition to reporting on the discovery of the simple binary SnN compound, this paper illustrates a possible way of combining a wide range of advanced characterization techniques with the first-principle property calculation methods, to elucidate the most likely crystal structure of the previously unreported metastable materials.

  6. Synthesis of a mixed-valent tin nitride and considerations of its possible crystal structures.

    PubMed

    Caskey, Christopher M; Holder, Aaron; Shulda, Sarah; Christensen, Steven T; Diercks, David; Schwartz, Craig P; Biagioni, David; Nordlund, Dennis; Kukliansky, Alon; Natan, Amir; Prendergast, David; Orvananos, Bernardo; Sun, Wenhao; Zhang, Xiuwen; Ceder, Gerbrand; Ginley, David S; Tumas, William; Perkins, John D; Stevanovic, Vladan; Pylypenko, Svitlana; Lany, Stephan; Richards, Ryan M; Zakutayev, Andriy

    2016-04-14

    Recent advances in theoretical structure prediction methods and high-throughput computational techniques are revolutionizing experimental discovery of the thermodynamically stable inorganic materials. Metastable materials represent a new frontier for these studies, since even simple binary non-ground state compounds of common elements may be awaiting discovery. However, there are significant research challenges related to non-equilibrium thin film synthesis and crystal structure predictions, such as small strained crystals in the experimental samples and energy minimization based theoretical algorithms. Here, we report on experimental synthesis and characterization, as well as theoretical first-principles calculations of a previously unreported mixed-valent binary tin nitride. Thin film experiments indicate that this novel material is N-deficient SnN with tin in the mixed ii/iv valence state and a small low-symmetry unit cell. Theoretical calculations suggest that the most likely crystal structure has the space group 2 (SG2) related to the distorted delafossite (SG166), which is nearly 0.1 eV/atom above the ground state SnN polymorph. This observation is rationalized by the structural similarity of the SnN distorted delafossite to the chemically related Sn3N4 spinel compound, which provides a fresh scientific insight into the reasons for growth of polymorphs of metastable materials. In addition to reporting on the discovery of the simple binary SnN compound, this paper illustrates a possible way of combining a wide range of advanced characterization techniques with the first-principle property calculation methods, to elucidate the most likely crystal structure of the previously unreported metastable materials.

  7. Synthesis of a mixed-valent tin nitride and considerations of its possible crystal structures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Caskey, Christopher M.; Colorado School of Mines, Golden, Colorado 80401; Larix Chemical Science, Golden, Colorado 80401

    2016-04-14

    Recent advances in theoretical structure prediction methods and high-throughput computational techniques are revolutionizing experimental discovery of the thermodynamically stable inorganic materials. Metastable materials represent a new frontier for these studies, since even simple binary non-ground state compounds of common elements may be awaiting discovery. However, there are significant research challenges related to non-equilibrium thin film synthesis and crystal structure predictions, such as small strained crystals in the experimental samples and energy minimization based theoretical algorithms. Here, we report on experimental synthesis and characterization, as well as theoretical first-principles calculations of a previously unreported mixed-valent binary tin nitride. Thin film experimentsmore » indicate that this novel material is N-deficient SnN with tin in the mixed II/IV valence state and a small low-symmetry unit cell. Theoretical calculations suggest that the most likely crystal structure has the space group 2 (SG2) related to the distorted delafossite (SG166), which is nearly 0.1 eV/atom above the ground state SnN polymorph. This observation is rationalized by the structural similarity of the SnN distorted delafossite to the chemically related Sn{sub 3}N{sub 4} spinel compound, which provides a fresh scientific insight into the reasons for growth of polymorphs of metastable materials. In addition to reporting on the discovery of the simple binary SnN compound, this paper illustrates a possible way of combining a wide range of advanced characterization techniques with the first-principle property calculation methods, to elucidate the most likely crystal structure of the previously unreported metastable materials.« less

  8. Phytochemical analysis and antioxidant capacity of BM-21, a bioactive extract rich in polyphenolic metabolites from the sea Grass Thalassia testudinum.

    PubMed

    Regalado, Erik L; Menendez, Roberto; Valdés, Olga; Morales, Ruth A; Laguna, Abilio; Thomas, Olivier P; Hernandez, Yasnay; Nogueiras, Clara; Kijjoa, Anake

    2012-01-01

    The aqueous ethanol extract of Thalassia testudinum leaves (BM-21) is now being developed in Cuba as an herbal medicine due to its promising pharmacological properties. Although some interesting biological activities of BM-21 have already been reported, its chemical composition remains mostly unknown. Thus, we now describe the qualitative and quantitative analyzes of BM-21 using standard phytochemical screening techniques, including colorimetric quantification, TLC and HPLC analyses. Phytochemical investigation of BM-21 resulted in the isolation and identification of a new phenolic sulfate ester (1), along with ten previously described phenolic derivatives (2-11), seven of which have never been previously reported from the genus Thalassia. The structures of these compounds were established by analysis of their spectroscopic (1D and 2D NMR) and spectrometric (HRMS) data, as well as by comparison of these with those reported in the literature. Furthermore, BM-21 was found to exhibit strong antioxidant activity in four different free radical scavenging assays (HO*, RO2*, O2-* and DPPH*). Consequently, this is the first study which highlights the phytochemical composition of BM-21 and demonstrates that this product is a rich source of natural antioxidants with potential applications in pharmaceutical, cosmetic and food industries.

  9. Assessment and Optimization of the Accuracy of an Aircraft-Based Technique Used to Quantify Greenhouse Gas Emission Rates from Point Sources

    NASA Astrophysics Data System (ADS)

    Shepson, P. B.; Lavoie, T. N.; Kerlo, A. E.; Stirm, B. H.

    2016-12-01

    Understanding the contribution of anthropogenic activities to atmospheric greenhouse gas concentrations requires an accurate characterization of emission sources. Previously, we have reported the use of a novel aircraft-based mass balance measurement technique to quantify greenhouse gas emission rates from point and area sources, however, the accuracy of this approach has not been evaluated to date. Here, an assessment of method accuracy and precision was performed by conducting a series of six aircraft-based mass balance experiments at a power plant in southern Indiana and comparing the calculated CO2 emission rates to the reported hourly emission measurements made by continuous emissions monitoring systems (CEMS) installed directly in the exhaust stacks at the facility. For all flights, CO2 emissions were quantified before CEMS data were released online to ensure unbiased analysis. Additionally, we assess the uncertainties introduced to the final emission rate caused by our analysis method, which employs a statistical kriging model to interpolate and extrapolate the CO2 fluxes across the flight transects from the ground to the top of the boundary layer. Subsequently, using the results from these flights combined with the known emissions reported by the CEMS, we perform an inter-model comparison of alternative kriging methods to evaluate the performance of the kriging approach.

  10. Measurement of the longitudinal and circumferential muscular activity associated with peristalsis using a single fibre grating array

    NASA Astrophysics Data System (ADS)

    Arkwright, J. W.; Blenman, N. G.; Underhill, I. D.; Maunder, S. A.; Spencer, N. J.; Costa, M.; Brooks, S. J.; Szczesniak, M. M.; Dinning, P. G.

    2010-09-01

    Diagnostic catheters based on fibre Bragg gratings (FBG's) are proving to be highly effective for measurement of the muscular activity associated with peristalsis in the human gut. The primary muscular contractions that generate peristalsis are circumferential in nature; however, it has long been known that there is also a component of longitudinal contractility present, acting in harmony with the circumferential component to improve the overall efficiency of material movement. To date, there have been relatively few reports on the measurement or inference of longitudinal contractions in humans and all have been limited to detection at a single location only. This is due to the lack of a viable recording technique suitable for real-time in-vivo measurement of this type of activity over extended lengths of the gut. We report the detection of longitudinal motion in lengths of excised mammalian colon using an FBG technique that should be viable for similar detection in humans. The longitudinal sensors have been combined with our previously reported FBG pressure sensing elements to form a composite catheter that allows the relative phase between the two components to be detected. The catheter output has been validated using digital video mapping in an ex-vivo animal preparation using lengths of rabbit ileum.

  11. Disrupted Cerebro-cerebellar Intrinsic Functional Connectivity in Young Adults with High-functioning Autism Spectrum Disorder: A Data-driven, Whole-brain, High Temporal Resolution fMRI Study.

    PubMed

    Arnold Anteraper, Sheeba; Guell, Xavier; D'Mello, Anila; Joshi, Neha; Whitfield-Gabrieli, Susan; Joshi, Gagan

    2018-06-13

    To examine the resting-state functional-connectivity (RsFc) in young adults with high-functioning autism spectrum disorder (HF-ASD) using state-of-the-art fMRI data acquisition and analysis techniques. Simultaneous multi-slice, high temporal resolution fMRI acquisition; unbiased whole-brain connectome-wide multivariate pattern analysis (MVPA) techniques for assessing RsFc; and post-hoc whole-brain seed-to-voxel analyses using MVPA results as seeds. MVPA revealed two clusters of abnormal connectivity in the cerebellum. Whole-brain seed-based functional connectivity analyses informed by MVPA-derived clusters showed significant under connectivity between the cerebellum and social, emotional, and language brain regions in the HF-ASD group compared to healthy controls. The results we report are coherent with existing structural, functional, and RsFc literature in autism, extend previous literature reporting cerebellar abnormalities in the neuropathology of autism, and highlight the cerebellum as a potential target for therapeutic, diagnostic, predictive, and prognostic developments in ASD. The description of functional connectivity abnormalities using whole-brain, data-driven analyses as reported in the present study may crucially advance the development of ASD biomarkers, targets for therapeutic interventions, and neural predictors for measuring treatment response.

  12. Dermoscopic findings in Laugier-Hunziker syndrome.

    PubMed

    Gencoglan, Gulsum; Gerceker-Turk, Bengu; Kilinc-Karaarslan, Isil; Akalin, Taner; Ozdemir, Fezal

    2007-05-01

    Laugier-Hunziker syndrome (LHS) is a rare, acquired mucocutaneous hyperpigmentation often associated with longitudinal melanonychia. The clinical behavior of mucocutaneous pigmented lesions ranges from benign to highly malignant. Therefore, in most cases, the clinical diagnosis should be confirmed by further diagnostic methods. Dermoscopy is a noninvasive technique that has been used to make more accurate diagnoses of pigmented skin lesions. Nevertheless, to our knowledge, the dermoscopic features of the pigmented lesions in LHS have not been described previously. Herein, we report a case of LHS together with its dermoscopic features. The clinical examination revealed macular hyperpigmentation on the oral and genital mucosa, conjunctiva, and palmoplantar region together with longitudinal melanonychia. Dermoscopic examination of mucosal lesions on the patient's lips and vulva revealed a parallel pattern. Longitudinal homogeneous pigmentation was observed on the toenails. The pigmented macules on the palms and the sole showed a parallel furrow pattern. A skin biopsy sample taken from the labial lesion was compatible with a diagnosis of mucosal melanosis. By means of this case report, the dermoscopic features of the pigmented lesions in LHS are described for the first time, which facilitates diagnosis with a noninvasive technique. Future reports highlighting the dermoscopic features of this syndrome may simplify the diagnosis of LHS, which is thought to be underdiagnosed.

  13. Preliminary data suggest rates of male military sexual trauma may be higher than previously reported.

    PubMed

    Sheppard, Sean C; Hickling, Edward J; Earleywine, Mitch; Hoyt, Tim; Russo, Amanda R; Donati, Matthew R; Kip, Kevin E

    2015-11-01

    Stigma associated with disclosing military sexual trauma (MST) makes estimating an accurate base rate difficult. Anonymous assessment may help alleviate stigma. Although anonymous research has found higher rates of male MST, no study has evaluated whether providing anonymity sufficiently mitigates the impact of stigma on accurate reporting. This study used the unmatched count technique (UCT), a form of randomized response techniques, to gain information about the accuracy of base rate estimates of male MST derived via anonymous assessment of Operation Enduring Freedom (OEF)/Operation Iraqi Freedom (OIF) combat veterans. A cross-sectional convenience sample of 180 OEF/OIF male combat veterans, recruited via online websites for military populations, provided data about history of MST via traditional anonymous self-report and the UCT. The UCT revealed a rate of male MST more than 15 times higher than the rate derived via traditional anonymous assessment (1.1% vs. 17.2%). These data suggest that anonymity does not adequately mitigate the impact of stigma on disclosure of male MST. Results, though preliminary, suggest that published rates of male MST may substantially underestimate the true rate of this problem. The UCT has significant potential to improve base rate estimation of sensitive behaviors in the military. (c) 2015 APA, all rights reserved).

  14. The Missed Inferior Alveolar Block: A New Look at an Old Problem

    PubMed Central

    Milles, Maano

    1984-01-01

    A variation of a previously described technique to obtain mandibular block anesthesia is presented. This technique varies from those previously described in that is uses palpable anatomic landmarks, both extra- and intraoral, to orient the placement of the needle. This technique relies on several readily observed landmarks and the integration of these landmarks. Because palpable landmarks are used, consistent results can be easily obtained even in patients who present with a wide variety of anatomical variances which otherwise make this injection technique difficult and prone to failure. ImagesFigure 1Figure 3Figure 4Figure 5Figure 6 PMID:6597690

  15. Mapping piezoelectric response in nanomaterials using a dedicated non-destructive scanning probe technique.

    PubMed

    Calahorra, Yonatan; Smith, Michael; Datta, Anuja; Benisty, Hadas; Kar-Narayan, Sohini

    2017-12-14

    There has been tremendous interest in piezoelectricity at the nanoscale, for example in nanowires and nanofibers where piezoelectric properties may be enhanced or controllably tuned, thus necessitating robust characterization techniques of piezoelectric response in nanomaterials. Piezo-response force microscopy (PFM) is a well-established scanning probe technique routinely used to image piezoelectric/ferroelectric domains in thin films, however, its applicability to nanoscale objects is limited due to the requirement for physical contact with an atomic force microscope (AFM) tip that may cause dislocation or damage, particularly to soft materials, during scanning. Here we report a non-destructive PFM (ND-PFM) technique wherein the tip is oscillated into "discontinuous" contact during scanning, while applying an AC bias between tip and sample and extracting the piezoelectric response for each contact point by monitoring the resulting localized deformation at the AC frequency. ND-PFM is successfully applied to soft polymeric (poly-l-lactic acid) nanowires, as well as hard ceramic (barium zirconate titanate-barium calcium titanate) nanowires, both previously inaccessible by conventional PFM. Our ND-PFM technique is versatile and compatible with commercial AFMs, and can be used to correlate piezoelectric properties of nanomaterials with their microstructural features thus overcoming key characterisation challenges in the field.

  16. Fabrication of large area woodpile structure in polymer

    NASA Astrophysics Data System (ADS)

    Gupta, Jaya Prakash; Dutta, Neilanjan; Yao, Peng; Sharkawy, Ahmed S.; Prather, Dennis W.

    2009-02-01

    A fabrication process of three-dimensional Woodpile photonic crystals based on multilayer photolithography from commercially available photo resist SU8 have been demonstrated. A 6-layer, 2 mm × 2mm woodpile has been fabricated. Different factors that influence the spin thickness on multiple resist application have been studied. The fabrication method used removes, the problem of intermixing, and is more repeatable and robust than the multilayer fabrication techniques for three dimensional photonic crystal structures that have been previously reported. Each layer is developed before next layer photo resist spin, instead of developing the whole structure in the final step as used in multilayer process. The desired thickness for each layer is achieved by the calibration of spin speed and use of different photo resist compositions. Deep UV exposure confinement has been the defining parameter in this process. Layer uniformity for every layer is independent of the previous developed layers and depends on the photo resist planarizing capability, spin parameters and baking conditions. The intermixing problem, which results from the previous layers left uncrossed linked photo resist, is completely removed in this process as the previous layers are fully developed, avoiding any intermixing between the newly spun and previous layers. Also this process gives the freedom to redo every spin any number of times without affecting the previously made structure, which is not possible in other multilayer process where intermediate developing is not performed.

  17. Chimpanzees (Pan troglodytes) display limited behavioural flexibility when faced with a changing foraging task requiring tool use

    PubMed Central

    Harrison, Rachel A.

    2018-01-01

    Behavioural flexibility, the ability to alter behaviour in response to environmental feedback, and to relinquish previously successful solutions to problems, is a crucial ability in allowing organisms to adapt to novel environments and environmental change; it is essential to cumulative cultural change. To explore this ability in chimpanzees, 18 individuals (Pan troglodytes) were presented with an artificial foraging task consisting of a tube partially filled with juice that could be reached by hand or retrieved using tool materials to hand. Effective solutions were then restricted in the second phase of the study by narrowing the diameter of the tube, necessitating the abandonment of previously successful solutions. Chimpanzees showed limited behavioural flexibility in comparison to some previous studies, increasing their use of effective techniques, but also continuing to attempt solutions that had been rendered ineffective. This adds to a literature reporting divergent evidence for flexibility (the ability to alter behaviour in response to environmental feedback, and to relinquish previously successful solutions to problems) versus conservatism (a reluctance or inability to explore or adopt novel solutions to problems when a solution is already known) in apes. PMID:29479495

  18. Using smartphones to collect daily sexual behavior data from college students.

    PubMed

    Willis, Malachi; Jozkowski, Kristen N

    2018-02-15

    Our objectives were to measure reporting differences between sexual behavior data from daily diary and retrospective estimates and to assess the utility of using smartphones to collect sexual behavior data from a college student population. Eighty-six participants (68 women, 18 men) completed the study. For 30 days during the Spring 2017 semester, participants received prompts to participate in daily diaries about their previous day's sexual behavior on their smartphones. Participants then retrospectively reported their past 30 days of sexual behavior and provided feedback on the process of receiving daily diaries on their smartphones. We found that college students overreported their sexual behavior on the retrospective survey compared to their daily diary reports (ps < .001; Cohen's ds ≥ 1.51). Participants provided positive and constructive feedback. Using smartphones to administer daily diaries is a promising technique for obtaining reliable sexual behavior data from college students.

  19. Recommendations report for the platanares geothermal site, Department of Copan, Honduras. Reporte de recomendaciones para el sitio geotermico de platanares, Departamento de Copan, Honduras (in EN;SP)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1988-11-01

    A geothermal assessment of six previously identified sites in Honduras has been conducted by a team comprised of staff from the Los Alamos National Laboratory, the US Geological Survey, and the Empresa Nacional de Energia Electrica. The application of both reconnaissance and detailed scale techniques lead to the selection of Platanares in the Department of Copan as the highest potential site. Additional work resulted in the completion of a prefeasibility study at Platanares. We present here a tabulation of the work completed and short summaries of the results from these technical studies. We also present a brief model of themore » geothermal system and recommendations for additional feasibility work. Both English and Spanish versions of this report are provided in the same document. 18 figs., 5 tabs.« less

  20. Evaluating the Impact of Conceptual Knowledge Engineering on the Design and Usability of a Clinical and Translational Science Collaboration Portal

    PubMed Central

    Payne, Philip R.O.; Borlawsky, Tara B.; Rice, Robert; Embi, Peter J.

    2010-01-01

    With the growing prevalence of large-scale, team science endeavors in the biomedical and life science domains, the impetus to implement platforms capable of supporting asynchronous interaction among multidisciplinary groups of collaborators has increased commensurately. However, there is a paucity of literature describing systematic approaches to identifying the information needs of targeted end-users for such platforms, and the translation of such requirements into practicable software component design criteria. In previous studies, we have reported upon the efficacy of employing conceptual knowledge engineering (CKE) techniques to systematically address both of the preceding challenges in the context of complex biomedical applications. In this manuscript we evaluate the impact of CKE approaches relative to the design of a clinical and translational science collaboration portal, and report upon the preliminary qualitative users satisfaction as reported for the resulting system. PMID:21347146

  1. Percutaneous Valvuloplasty for Bioprosthetic Tricuspid Valve Stenosis

    PubMed Central

    Malhotra, Rohit; Sharma, Anjali; Kakouros, Nikolaos

    2017-01-01

    Percutaneous transcatheter tricuspid balloon valvuloplasty (PTTBV) is an accepted treatment option for symptomatic severe native tricuspid valve stenosis, although surgical tricuspid valve replacement remains the treatment of choice. There have been few reports of successful PTTBV for bioprosthetic tricuspid valve stenosis. We present case reports of 3 patients from our hospital experience. Two of the 3 cases were successful, with lasting clinical improvement, whereas the 3rd patient failed to show a reduction in valve gradient. We describe the standard technique used for PTTBV. We present results from a literature review that identified 16 previously reported cases of PTTBV for bioprosthetic severe tricuspid stenosis, with overall favorable results. We conclude that PTTBV should perhaps be considered for a select patient population in which symptomatic improvement and hemodynamic stability are desired immediately, and particularly for patients who are inoperable or at high surgical risk. PMID:28265212

  2. Static testing of a bridge using an interferometric radar: the case study of "Ponte degli Alpini," Belluno, Italy.

    PubMed

    Dei, Devis; Mecatti, Daniele; Pieraccini, Massimiliano

    2013-01-01

    Ground-based radar interferometry is an increasingly popular technique for monitoring civil infrastructures. In this paper, the static testing of a bridge is reported. It was an 8-span bridge, 297 m long, named "Ponte degli Alpini," crossing the valley of the Ardo River. The radar has been used for testing a lateral span and a central span. The obtained results present elements of novelty not previously reported in the literature. In fact, some displacement measurements of the lateral span have been affected by a horizontal shift that has to be taken into account for a correct interpretation of the measured data. Furthermore, the measurements of the central span have been carried out with the radar positioned transversally with respect to the bridge deck; this unusual arrangement has allowed for obtaining displacement maps less geometrically distorted with respect to other cases reported in the literature.

  3. Simplified ab externo fixation technique to treat late dislocation of scleral-sutured polymethyl methacrylate intraocular lenses

    PubMed Central

    Lyu, J; Zhao, P-q

    2016-01-01

    Purpose We report a simplified ab externo scleral fixation technique to manage the late dislocation of scleral-sutured polymethyl methacrylate (PMMA) intraocular lenses (IOLs) in the absence of capsule support. Materials and methods The technique was performed on five eyes of five patients. Symmetrical scleral pocket tunnels without conjunctival peritomy were created. An anterior vitrectomy via a limbal approach with an anterior chamber infusion or a 3-port pars plana vitrectomy was performed to rescue the dislocated IOL. A long straight suture needle and 23-gauge vitreoretinal forceps were used to conveniently reposition the IOL and loop sutures through the IOL positioning eyelets without externalizing IOL haptics. The outside suture knots were buried under the roof of the scleral tunnels. Results The patients were followed for 5–14 months after surgery. All the operated eyes quickly recovered with negligible corneal endothelial cell loss and mild inflammation. Visual acuity improvement and IOL centration were achieved in all eyes with no major complications. Conclusion The simplified ab externo scleral fixation technique offers an effective and minimally invasive surgical alternative to salvage dislocated previously scleral-sutured PMMA IOLs. PMID:26795420

  4. A novel background field removal method for MRI using projection onto dipole fields (PDF).

    PubMed

    Liu, Tian; Khalidov, Ildar; de Rochefort, Ludovic; Spincemaille, Pascal; Liu, Jing; Tsiouris, A John; Wang, Yi

    2011-11-01

    For optimal image quality in susceptibility-weighted imaging and accurate quantification of susceptibility, it is necessary to isolate the local field generated by local magnetic sources (such as iron) from the background field that arises from imperfect shimming and variations in magnetic susceptibility of surrounding tissues (including air). Previous background removal techniques have limited effectiveness depending on the accuracy of model assumptions or information input. In this article, we report an observation that the magnetic field for a dipole outside a given region of interest (ROI) is approximately orthogonal to the magnetic field of a dipole inside the ROI. Accordingly, we propose a nonparametric background field removal technique based on projection onto dipole fields (PDF). In this PDF technique, the background field inside an ROI is decomposed into a field originating from dipoles outside the ROI using the projection theorem in Hilbert space. This novel PDF background removal technique was validated on a numerical simulation and a phantom experiment and was applied in human brain imaging, demonstrating substantial improvement in background field removal compared with the commonly used high-pass filtering method. Copyright © 2011 John Wiley & Sons, Ltd.

  5. Simplified ab externo fixation technique to treat late dislocation of scleral-sutured polymethyl methacrylate intraocular lenses.

    PubMed

    Lyu, J; Zhao, P-Q

    2016-05-01

    PurposeWe report a simplified ab externo scleral fixation technique to manage the late dislocation of scleral-sutured polymethyl methacrylate (PMMA) intraocular lenses (IOLs) in the absence of capsule support.Materials and methodsThe technique was performed on five eyes of five patients. Symmetrical scleral pocket tunnels without conjunctival peritomy were created. An anterior vitrectomy via a limbal approach with an anterior chamber infusion or a 3-port pars plana vitrectomy was performed to rescue the dislocated IOL. A long straight suture needle and 23-gauge vitreoretinal forceps were used to conveniently reposition the IOL and loop sutures through the IOL positioning eyelets without externalizing IOL haptics. The outside suture knots were buried under the roof of the scleral tunnels.ResultsThe patients were followed for 5-14 months after surgery. All the operated eyes quickly recovered with negligible corneal endothelial cell loss and mild inflammation. Visual acuity improvement and IOL centration were achieved in all eyes with no major complications.ConclusionThe simplified ab externo scleral fixation technique offers an effective and minimally invasive surgical alternative to salvage dislocated previously scleral-sutured PMMA IOLs.

  6. Identification of transformer fault based on dissolved gas analysis using hybrid support vector machine-modified evolutionary particle swarm optimisation

    PubMed Central

    2018-01-01

    Early detection of power transformer fault is important because it can reduce the maintenance cost of the transformer and it can ensure continuous electricity supply in power systems. Dissolved Gas Analysis (DGA) technique is commonly used to identify oil-filled power transformer fault type but utilisation of artificial intelligence method with optimisation methods has shown convincing results. In this work, a hybrid support vector machine (SVM) with modified evolutionary particle swarm optimisation (EPSO) algorithm was proposed to determine the transformer fault type. The superiority of the modified PSO technique with SVM was evaluated by comparing the results with the actual fault diagnosis, unoptimised SVM and previous reported works. Data reduction was also applied using stepwise regression prior to the training process of SVM to reduce the training time. It was found that the proposed hybrid SVM-Modified EPSO (MEPSO)-Time Varying Acceleration Coefficient (TVAC) technique results in the highest correct identification percentage of faults in a power transformer compared to other PSO algorithms. Thus, the proposed technique can be one of the potential solutions to identify the transformer fault type based on DGA data on site. PMID:29370230

  7. Identification of transformer fault based on dissolved gas analysis using hybrid support vector machine-modified evolutionary particle swarm optimisation.

    PubMed

    Illias, Hazlee Azil; Zhao Liang, Wee

    2018-01-01

    Early detection of power transformer fault is important because it can reduce the maintenance cost of the transformer and it can ensure continuous electricity supply in power systems. Dissolved Gas Analysis (DGA) technique is commonly used to identify oil-filled power transformer fault type but utilisation of artificial intelligence method with optimisation methods has shown convincing results. In this work, a hybrid support vector machine (SVM) with modified evolutionary particle swarm optimisation (EPSO) algorithm was proposed to determine the transformer fault type. The superiority of the modified PSO technique with SVM was evaluated by comparing the results with the actual fault diagnosis, unoptimised SVM and previous reported works. Data reduction was also applied using stepwise regression prior to the training process of SVM to reduce the training time. It was found that the proposed hybrid SVM-Modified EPSO (MEPSO)-Time Varying Acceleration Coefficient (TVAC) technique results in the highest correct identification percentage of faults in a power transformer compared to other PSO algorithms. Thus, the proposed technique can be one of the potential solutions to identify the transformer fault type based on DGA data on site.

  8. Tone and Broadband Noise Separation from Acoustic Data of a Scale-Model Counter-Rotating Open Rotor

    NASA Technical Reports Server (NTRS)

    Sree, David; Stephens, David B.

    2014-01-01

    Renewed interest in contra-rotating open rotor technology for aircraft propulsion application has prompted the development of advanced diagnostic tools for better design and improved acoustical performance. In particular, the determination of tonal and broadband components of open rotor acoustic spectra is essential for properly assessing the noise control parameters and also for validating the open rotor noise simulation codes. The technique of phase averaging has been employed to separate the tone and broadband components from a single rotor, but this method does not work for the two-shaft contra-rotating open rotor. A new signal processing technique was recently developed to process the contra-rotating open rotor acoustic data. The technique was first tested using acoustic data taken of a hobby aircraft open rotor propeller, and reported previously. The intent of the present work is to verify and validate the applicability of the new technique to a realistic one-fifth scale open rotor model which has 12 forward and 10 aft contra-rotating blades operating at realistic forward flight Mach numbers and tip speeds. The results and discussions of that study are presented in this paper.

  9. Tone and Broadband Noise Separation from Acoustic Data of a Scale-Model Contra-Rotating Open Rotor

    NASA Technical Reports Server (NTRS)

    Sree, Dave; Stephens, David B.

    2014-01-01

    Renewed interest in contra-rotating open rotor technology for aircraft propulsion application has prompted the development of advanced diagnostic tools for better design and improved acoustical performance. In particular, the determination of tonal and broadband components of open rotor acoustic spectra is essential for properly assessing the noise control parameters and also for validating the open rotor noise simulation codes. The technique of phase averaging has been employed to separate the tone and broadband components from a single rotor, but this method does not work for the two-shaft contra-rotating open rotor. A new signal processing technique was recently developed to process the contra-rotating open rotor acoustic data. The technique was first tested using acoustic data taken of a hobby aircraft open rotor propeller, and reported previously. The intent of the present work is to verify and validate the applicability of the new technique to a realistic one-fifth scale open rotor model which has 12 forward and 10 aft contra-rotating blades operating at realistic forward flight Mach numbers and tip speeds. The results and discussions of that study are presented in this paper.

  10. Accurate Distances to Important Spiral Galaxies: M63, M74, NGC 1291, NGC 4559, NGC 4625, and NGC 5398

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McQuinn, Kristen B. W.; Skillman, Evan D.; Dolphin, Andrew E.

    Accurate distances are fundamental for interpreting various measured properties of galaxies. Surprisingly, many of the best-studied spiral galaxies in the Local Volume have distance uncertainties that are much larger than can be achieved with modern observation techniques. Using Hubble Space Telescope optical imaging, we use the tip of the red giant branch method to measure the distances to six galaxies that are included in the Spitzer Infrared Nearby Galaxies Survey program and its offspring surveys. The sample includes M63, M74, NGC 1291, NGC 4559, NGC 4625, and NGC 5398. We compare our results with distances reported to these galaxies basedmore » on a variety of methods. Depending on the technique, there can be a wide range in published distances, particularly from the Tully–Fisher relation. In addition, differences between the planetary nebular luminosity function and surface brightness fluctuation techniques can vary between galaxies, suggesting inaccuracies that cannot be explained by systematics in the calibrations. Our distances improve upon previous results, as we use a well-calibrated, stable distance indicator, precision photometry in an optimally selected field of view, and a Bayesian maximum likelihood technique that reduces measurement uncertainties.« less

  11. Application of Function-Failure Similarity Method to Rotorcraft Component Design

    NASA Technical Reports Server (NTRS)

    Roberts, Rory A.; Stone, Robert E.; Tumer, Irem Y.; Clancy, Daniel (Technical Monitor)

    2002-01-01

    Performance and safety are the top concerns of high-risk aerospace applications at NASA. Eliminating or reducing performance and safety problems can be achieved with a thorough understanding of potential failure modes in the designs that lead to these problems. The majority of techniques use prior knowledge and experience as well as Failure Modes and Effects as methods to determine potential failure modes of aircraft. During the design of aircraft, a general technique is needed to ensure that every potential failure mode is considered, while avoiding spending time on improbable failure modes. In this work, this is accomplished by mapping failure modes to specific components, which are described by their functionality. The failure modes are then linked to the basic functions that are carried within the components of the aircraft. Using this technique, designers can examine the basic functions, and select appropriate analyses to eliminate or design out the potential failure modes. The fundamentals of this method were previously introduced for a simple rotating machine test rig with basic functions that are common to a rotorcraft. In this paper, this technique is applied to the engine and power train of a rotorcraft, using failures and functions obtained from accident reports and engineering drawings.

  12. Advanced Signal Processing for High Temperatures Health Monitoring of Condensed Water Height in Steam Pipes

    NASA Technical Reports Server (NTRS)

    Lih, Shyh-Shiuh; Bar-Cohen, Yoseph; Lee, Hyeong Jae; Takano, Nobuyuki; Bao, Xiaoqi

    2013-01-01

    An advanced signal processing methodology is being developed to monitor the height of condensed water thru the wall of a steel pipe while operating at temperatures as high as 250deg. Using existing techniques, previous study indicated that, when the water height is low or there is disturbance in the environment, the predicted water height may not be accurate. In recent years, the use of the autocorrelation and envelope techniques in the signal processing has been demonstrated to be a very useful tool for practical applications. In this paper, various signal processing techniques including the auto correlation, Hilbert transform, and the Shannon Energy Envelope methods were studied and implemented to determine the water height in the steam pipe. The results have shown that the developed method provides a good capability for monitoring the height in the regular conditions. An alternative solution for shallow water or no water conditions based on a developed hybrid method based on Hilbert transform (HT) with a high pass filter and using the optimized windowing technique is suggested. Further development of the reported methods would provide a powerful tool for the identification of the disturbances of water height inside the pipe.

  13. Molecular techniques to distinguish morphologically similar Hydrilla verticillata, Egeria densa, Elodea nuttallii, and Elodea canadensis

    USGS Publications Warehouse

    Rybicki, Nancy B.; Kirshtein, Julie D.; Voytek, Mary A.

    2013-01-01

    The four submerged aquatic species, hydrilla (Hydrilla verticillata [monoecious and dioecious]), Brazilian waterweed (Egeria densa), Canadian waterweed (Elodea canadensis), and western waterweed (Elodea nuttallii), are difficult to positively identify because of their morphological similarity to each other, resulting in possible misidentification. This limits our ability to understand their past and present distribution, which is important in aquatic plant management. We investigated a molecular technique to identify these species, which are problematic because of their invasive nature on multiple continents. Approximately 100 samples of these species, ranging in age from 40-yr-old herbarium samples to recently collected plants, were collected from regions across the United States. The distribution and range of the samples collected in this research were compared to those reported in the literature. We confirmed information on the current wide distribution of both hydrilla biotypes in the United States and discovered that hydrilla had actually invaded the waterways near Washington, DC 6 yr earlier than originally reported. In addition, we found evidence of the confusion, dating back to the 1980s, between Canadian waterweed and western waterweed in the mid-Atlantic region of the United States. Canadian waterweed was previously reported as common and western waterweed as rare; however, our samples indicate the opposite is true. This information indicates there is a need for investigators to anticipate the spread of hydrilla populations to northern U.S. waterways, where it will compete with existing plant species, including Canadian and western waterweeds. Our ability to confirm distribution and pace of spread of invasive and noninvasive species will improve with increased application of molecular techniques.

  14. Dupuytren disease: European hand surgeons, hand therapists, and physical medicine and rehabilitation physicians agree on a multidisciplinary treatment guideline: results from the HANDGUIDE study.

    PubMed

    Huisstede, Bionka M A; Hoogvliet, Peter; Coert, J Henk; Fridén, Jan

    2013-12-01

    Multidisciplinary treatment guidelines for Dupuytren disease can aid in optimizing the quality of care for patients with this disorder. Therefore, this study aimed to achieve consensus on a multidisciplinary treatment guideline for Dupuytren disease. A European Delphi consensus strategy was initiated. A systematic review reporting on the effectiveness of interventions was conducted and used as an evidence-based starting point for this study. In total, 39 experts (hand surgeons, hand therapists, and physical medicine and rehabilitation physicians) participated in the Delphi consensus strategy. Each Delphi round consisted of a questionnaire, an analysis, and a feedback report. After four Delphi rounds, consensus was achieved on the description, symptoms, and diagnosis of Dupuytren disease. No nonsurgical interventions were included in the guideline. Needle and open fasciotomy, and a limited fasciectomy and dermofasciectomy, were seen as suitable surgical techniques for Dupuytren disease. Factors relevant for choosing one of these surgical techniques were identified and divided into patient-related (age, comorbidity), disease-related (palpable cord, previous surgery in the same area, skin involvement, time of recovery, recurrences), and surgeon-related (years of experience) factors. Associations of these factors with the choice of a specific surgical technique were reported in the guideline. Postsurgical rehabilitation should always include instructions and exercise therapy; postsurgical splinting should be performed on indication. Relevant details for the use of surgical and postsurgical interventions were described. This treatment guideline is likely to promote further discussion on related clinical and scientific issues and may therefore contribute to better treatment of patients with Dupuytren disease.

  15. Survey of equine castration techniques, preferences and outcomes among Australian veterinarians.

    PubMed

    Owens, C D; Hughes, K J; Hilbert, B J; Heller, J; Nielsen, S; Trope, G D

    2018-01-01

    (1) To collect the perceptions of veterinarians performing equine castrations in Australia on techniques, preferences and outcomes, (2) to investigate veterinarian use and experience with the Henderson castrating instrument and (3) to investigate potential associations between demographics, castration methods and techniques, and complications. Online survey of members of the Australian Veterinary Association's Special Interest Group, Equine Veterinarians Australia (EVA). A link to the survey was included in the EVA e-newsletter and practices on the EVA website were contacted by telephone and follow-up email. Fisher's exact test was used to determine associations between ligation and complications. A generalised linear model with a negative binomial family was used to determine associations between count response variables and categorical independent variables. Responses were obtained from 138 veterinarians (response rate, 13.1%) who performed 5330 castrations over 12 months. Castrations were most commonly performed in the field, on anaesthetised horses, using emasculators, via an open approach and without ligation of the spermatic cord. Estimated complications after use of emasculators were swelling (25%), haemorrhage (5%) and infection (5%). The Henderson instrument was used by approximately 10% of respondents and its use for castration was associated with fewer reports of postoperative swelling compared with emasculators (P = 0.002). Rates of evisceration with the Henderson and emasculator methods were comparable (0.43% and 0.9%, respectively). Castration preferences varied widely among survey participants. Reported complication types and rates were comparable to those reported previously in other countries. Perceptions that the Henderson instrument was associated with less swelling should be investigated further via a prospective controlled investigation. © 2017 Australian Veterinary Association.

  16. Thoracic respiratory motion estimation from MRI using a statistical model and a 2-D image navigator.

    PubMed

    King, A P; Buerger, C; Tsoumpas, C; Marsden, P K; Schaeffter, T

    2012-01-01

    Respiratory motion models have potential application for estimating and correcting the effects of motion in a wide range of applications, for example in PET-MR imaging. Given that motion cycles caused by breathing are only approximately repeatable, an important quality of such models is their ability to capture and estimate the intra- and inter-cycle variability of the motion. In this paper we propose and describe a technique for free-form nonrigid respiratory motion correction in the thorax. Our model is based on a principal component analysis of the motion states encountered during different breathing patterns, and is formed from motion estimates made from dynamic 3-D MRI data. We apply our model using a data-driven technique based on a 2-D MRI image navigator. Unlike most previously reported work in the literature, our approach is able to capture both intra- and inter-cycle motion variability. In addition, the 2-D image navigator can be used to estimate how applicable the current motion model is, and hence report when more imaging data is required to update the model. We also use the motion model to decide on the best positioning for the image navigator. We validate our approach using MRI data acquired from 10 volunteers and demonstrate improvements of up to 40.5% over other reported motion modelling approaches, which corresponds to 61% of the overall respiratory motion present. Finally we demonstrate one potential application of our technique: MRI-based motion correction of real-time PET data for simultaneous PET-MRI acquisition. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. High Prevalence of Schistosoma japonicum Infection in Carabao from Samar Province, the Philippines: Implications for Transmission and Control

    PubMed Central

    Gordon, Catherine A.; Acosta, Luz P.; Gray, Darren J.; Olveda, Remigo M.; Jarilla, Blanca; Gobert, Geoffrey N.; Ross, Allen G.; McManus, Donald P.

    2012-01-01

    Schistosoma japonicum is endemic in the Philippines, China and Indonesia, and infects more than 40 mammalian host species, all of which can act as reservoirs of infection. In China, water buffaloes have been shown to be major reservoirs of human infection. However, in the Philippines, carabao have not been considered important reservoir hosts for S. japonicum due to the low prevalence and infection intensities reported, the only exception being a qPCR-based study indicating 51% of carabao were S. japonicum-positive. However, the low prevalence found for the same animals when using conventional copro-parasitological techniques means that there is still confusion about the role of carabao in the transmission of schistosomiasis japonicum. To address this inconsistency, and to shed light on the potential role of carabao in the transmission of S. japonicum in the Philippines, we undertook a pilot survey, collecting fecal samples from animals in Western Samar Province and we used a combination of molecular and copro-parasitological techniques to determine the prevalence and intensity of S. japonicum. We found a high prevalence of S. japonicum in the carabao using a validated real-time PCR (qPCR) and a copro-parasitological tool, the formalin-ethyl acetate sedimentation (FEA-SD) technique. A much lower prevalence of S. japonicum was recorded for the same fecal samples using conventional PCR, the Kato-Katz technique and miracidial hatching. These results suggest that, due to their low diagnostic sensitivity, traditional copro-parasitological techniques underestimate infection in carabao. The use of FEA-SD and qPCR provides a more accurate diagnosis. Based on these findings, the role of bovines in the transmission of S. japonicum appears to be more important in the Philippines than previously recognized, and this may have significant implications for the future control of schistosomiasis there, particularly as, in contrast with previous surveys, we found an unprecedented high prevalence of S. japonicum in humans. PMID:23029571

  18. Revisiting the Estimation of Dinosaur Growth Rates

    PubMed Central

    Myhrvold, Nathan P.

    2013-01-01

    Previous growth-rate studies covering 14 dinosaur taxa, as represented by 31 data sets, are critically examined and reanalyzed by using improved statistical techniques. The examination reveals that some previously reported results cannot be replicated by using the methods originally reported; results from new methods are in many cases different, in both the quantitative rates and the qualitative nature of the growth, from results in the prior literature. Asymptotic growth curves, which have been hypothesized to be ubiquitous, are shown to provide best fits for only four of the 14 taxa. Possible reasons for non-asymptotic growth patterns are discussed; they include systematic errors in the age-estimation process and, more likely, a bias toward younger ages among the specimens analyzed. Analysis of the data sets finds that only three taxa include specimens that could be considered skeletally mature (i.e., having attained 90% of maximum body size predicted by asymptotic curve fits), and eleven taxa are quite immature, with the largest specimen having attained less than 62% of predicted asymptotic size. The three taxa that include skeletally mature specimens are included in the four taxa that are best fit by asymptotic curves. The totality of results presented here suggests that previous estimates of both maximum dinosaur growth rates and maximum dinosaur sizes have little statistical support. Suggestions for future research are presented. PMID:24358133

  19. Massage therapy techniques as pain management for erythromelalgia: a case report.

    PubMed

    Dicks, Krista; Rizek, Philippe

    2010-12-16

    Erythromelalgia is characterized by temperature-dependent redness, pain, and warmth in one or more extremities. It may be a primary disease, or it may occur secondarily because of underlying illness. It is a chronic, debilitating condition often resistant to medical treatment. The present report evaluates massage as a complementary therapy to reduce pain and other symptoms associated with erythromelalgia. A 31-year-old female with a long-standing history of erythromelalgia bilaterally in the lower extremities presented with complaints of acute pain exacerbation, anxiety, decreased quality of sleep, and difficulty with activities of daily living for prolonged periods of time. She had no previous experience with massage therapy or any other complementary therapies. Massage therapy was introduced over the course of 9 treatments, each 1 hour in duration, using various massage therapy techniques, remedial exercise, and recommended home care. In this patient with erythromelalgia, effleurage and petrissage as massage therapy techniques provided temporary pain relief in the lower extremities and long-term benefits that relieved anxiety, which improved restorative sleep and increased the patient's participation in activities of daily living. For this treatment protocol, therapist observation and patient feedback suggest that massage therapy may lead to a state of increased relaxation, decreased stress, decreased muscle tension, and improved sleep. These positive effects may have an indirect role in the ability of the patient to cope with erythromelalgia day to day.

  20. Estimating the magnitude of peak flows for streams in Kentucky for selected recurrence intervals

    USGS Publications Warehouse

    Hodgkins, Glenn A.; Martin, Gary R.

    2003-01-01

    This report gives estimates of, and presents techniques for estimating, the magnitude of peak flows for streams in Kentucky for recurrence intervals of 2, 5, 10, 25, 50, 100, 200, and 500 years. A flowchart in this report guides the user to the appropriate estimates and (or) estimating techniques for a site on a specific stream. Estimates of peak flows are given for 222 U.S. Geological Survey streamflow-gaging stations in Kentucky. In the development of the peak-flow estimates at gaging stations, a new generalized skew coefficient was calculated for the State. This single statewide value of 0.011 (with a standard error of prediction of 0.520) is more appropriate for Kentucky than the national skew isoline map in Bulletin 17B of the Interagency Advisory Committee on Water Data. Regression equations are presented for estimating the peak flows on ungaged, unregulated streams in rural drainage basins. The equations were developed by use of generalized-least-squares regression procedures at 187 U.S. Geological Survey gaging stations in Kentucky and 51 stations in surrounding States. Kentucky was divided into seven flood regions. Total drainage area is used in the final regression equations as the sole explanatory variable, except in Regions 1 and 4 where main-channel slope also was used. The smallest average standard errors of prediction were in Region 3 (from -13.1 to +15.0 percent) and the largest average standard errors of prediction were in Region 5 (from -37.6 to +60.3 percent). One section of this report describes techniques for estimating peak flows for ungaged sites on gaged, unregulated streams in rural drainage basins. Another section references two previous U.S. Geological Survey reports for peak-flow estimates on ungaged, unregulated, urban streams. Estimating peak flows at ungaged sites on regulated streams is beyond the scope of this report, because peak flows on regulated streams are dependent upon variable human activities.

Top